diff --git a/docs/sap-spec/pcdb_table_105_gas_oil_boilers.jsonl b/docs/sap-spec/pcdb_table_105_gas_oil_boilers.jsonl index 8dbb5dd7..519d55c9 100644 --- a/docs/sap-spec/pcdb_table_105_gas_oil_boilers.jsonl +++ b/docs/sap-spec/pcdb_table_105_gas_oil_boilers.jsonl @@ -1,7236 +1,7236 @@ -{"pcdb_id": 98, "brand_name": "Baxi Heating", "model_name": "Wm", "model_qualifier": "20/3rs", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 5.86, "final_year_of_manufacture": 1990, "raw": ["000098", "000005", "0", "2010/Sep/13 17:03", "Baxi Heating", "Baxi Heating", "Wm", "20/3rs", "4107739", "", "1990", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "5.86", "5.86", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 99, "brand_name": "Baxi Heating", "model_name": "Wm", "model_qualifier": "281rs", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 8.2, "final_year_of_manufacture": 1984, "raw": ["000099", "000005", "0", "2010/Sep/13 17:03", "Baxi Heating", "Baxi Heating", "Wm", "281rs", "4107707", "", "1984", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "8.2", "8.2", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 100, "brand_name": "Baxi Heating", "model_name": "Wm", "model_qualifier": "282rs", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 8.2, "final_year_of_manufacture": 1984, "raw": ["000100", "000005", "0", "2010/Sep/13 17:03", "Baxi Heating", "Baxi Heating", "Wm", "282rs", "4107731", "", "1984", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "8.2", "8.2", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 102, "brand_name": "Baxi Heating", "model_name": "Wm", "model_qualifier": "38/3", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 11.14, "final_year_of_manufacture": 1990, "raw": ["000102", "000005", "0", "2010/Sep/13 17:03", "Baxi Heating", "Baxi Heating", "Wm", "38/3", "4107735", "", "1990", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "11.14", "11.14", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 103, "brand_name": "Baxi Heating", "model_name": "Wm", "model_qualifier": "381rs", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 11.14, "final_year_of_manufacture": 1984, "raw": ["000103", "000005", "0", "2010/Sep/13 17:03", "Baxi Heating", "Baxi Heating", "Wm", "381rs", "4107705", "", "1984", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "11.14", "11.14", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 104, "brand_name": "Baxi Heating", "model_name": "Wm", "model_qualifier": "382rs", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 11.14, "final_year_of_manufacture": 1984, "raw": ["000104", "000005", "0", "2010/Sep/13 17:03", "Baxi Heating", "Baxi Heating", "Wm", "382rs", "4107732", "", "1984", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "11.14", "11.14", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 105, "brand_name": "Baxi Heating", "model_name": "Wm", "model_qualifier": "40/3of", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 11.73, "final_year_of_manufacture": 1990, "raw": ["000105", "000005", "0", "2010/Sep/13 17:03", "Baxi Heating", "Baxi Heating", "Wm", "40/3of", "4107738", "", "1990", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "11.73", "11.73", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 106, "brand_name": "Baxi Heating", "model_name": "Wm", "model_qualifier": "401of", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 11.73, "final_year_of_manufacture": 1981, "raw": ["000106", "000005", "0", "2010/Sep/13 17:03", "Baxi Heating", "Baxi Heating", "Wm", "401of", "4107704", "", "1981", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "11.73", "11.73", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 108, "brand_name": "Baxi Heating", "model_name": "Wm", "model_qualifier": "402of", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 11.73, "final_year_of_manufacture": 1984, "raw": ["000108", "000005", "0", "2010/Sep/13 17:03", "Baxi Heating", "Baxi Heating", "Wm", "402of", "4107709", "", "1984", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "11.73", "11.73", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 109, "brand_name": "Baxi Heating", "model_name": "Wm", "model_qualifier": "51/3", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 14.95, "final_year_of_manufacture": 1990, "raw": ["000109", "000005", "0", "2010/Sep/13 17:03", "Baxi Heating", "Baxi Heating", "Wm", "51/3", "4107734", "", "1990", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "14.95", "14.95", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 110, "brand_name": "Baxi Heating", "model_name": "Wm", "model_qualifier": "511rs", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 15.0, "final_year_of_manufacture": 1984, "raw": ["000110", "000005", "0", "2010/Sep/13 17:03", "Baxi Heating", "Baxi Heating", "Wm", "511rs", "4107708", "", "1984", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "15", "15", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 111, "brand_name": "Baxi Heating", "model_name": "Wm", "model_qualifier": "512rs", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 15.0, "final_year_of_manufacture": 1984, "raw": ["000111", "000005", "0", "2010/Sep/13 17:03", "Baxi Heating", "Baxi Heating", "Wm", "512rs", "4107733", "", "1984", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "15", "15", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 113, "brand_name": "Baxi Heating", "model_name": "Wm", "model_qualifier": "532rs", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 15.5, "final_year_of_manufacture": 1981, "raw": ["000113", "000005", "0", "2010/Sep/13 17:03", "Baxi Heating", "Baxi Heating", "Wm", "532rs", "4107706", "", "1981", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "15.5", "15.5", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 114, "brand_name": "Baxi Heating", "model_name": "Wm", "model_qualifier": "55/3of", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 16.1, "final_year_of_manufacture": 1990, "raw": ["000114", "000005", "0", "2010/Sep/13 17:03", "Baxi Heating", "Baxi Heating", "Wm", "55/3of", "4107737", "", "1990", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "16.1", "16.1", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 115, "brand_name": "Baxi Heating", "model_name": "Wm", "model_qualifier": "551of", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 16.11, "final_year_of_manufacture": 1981, "raw": ["000115", "000005", "0", "2010/Sep/13 17:03", "Baxi Heating", "Baxi Heating", "Wm", "551of", "4107702", "", "1981", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "16.11", "16.11", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 116, "brand_name": "Baxi Heating", "model_name": "Wm", "model_qualifier": "552of", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 16.12, "final_year_of_manufacture": 1984, "raw": ["000116", "000005", "0", "2010/Sep/13 17:03", "Baxi Heating", "Baxi Heating", "Wm", "552of", "4107710", "", "1984", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "16.12", "16.12", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 117, "brand_name": "Baxi Heating", "model_name": "Wm", "model_qualifier": "60/3rs", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 17.38, "final_year_of_manufacture": 1990, "raw": ["000117", "000005", "0", "2010/Sep/13 17:03", "Baxi Heating", "Baxi Heating", "Wm", "60/3rs", "4107740", "", "1990", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "17.38", "17.38", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 126, "brand_name": "Broag Remeha", "model_name": "W40M Eco", "model_qualifier": "", "winter_efficiency_pct": 91.0, "summer_efficiency_pct": 74.0, "comparative_hot_water_efficiency_pct": 53.7, "output_kw_max": null, "final_year_of_manufacture": 1999, "raw": ["000126", "000006", "0", "2010/Sep/13 17:03", "Broag", "Broag Remeha", "W40M Eco", "", "", "", "1999", "1", "0", "0", "1", "0", "", "", "2", "2", "2", "", "", "", "", "91.0", "74.0", "", "53.7", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0001", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 127, "brand_name": "Broag Remeha", "model_name": "W60M Eco", "model_qualifier": "", "winter_efficiency_pct": 91.0, "summer_efficiency_pct": 74.0, "comparative_hot_water_efficiency_pct": 53.7, "output_kw_max": null, "final_year_of_manufacture": 1999, "raw": ["000127", "000006", "0", "2010/Sep/13 17:03", "Broag", "Broag Remeha", "W60M Eco", "", "", "", "1999", "1", "0", "0", "1", "0", "", "", "2", "2", "2", "", "", "", "", "91.0", "74.0", "", "53.7", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0001", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 130, "brand_name": "Burco Maxol", "model_name": "Microturbo", "model_qualifier": "40 SRF & 40 MDF", "winter_efficiency_pct": 69.0, "summer_efficiency_pct": 59.0, "comparative_hot_water_efficiency_pct": 43.0, "output_kw_max": 11.7, "final_year_of_manufacture": 1998, "raw": ["000130", "000007", "0", "2010/Sep/13 17:03", "Burco Maxol", "Burco Maxol", "Microturbo", "40 SRF & 40 MDF", "4120219", "", "1998", "1", "0", "0", "1", "0", "", "", "1", "2", "2", "11.7", "11.7", "", "", "69.0", "59.0", "", "43.0", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 131, "brand_name": "Burco Maxol", "model_name": "Microturbo", "model_qualifier": "50 SRF & 50 MDF", "winter_efficiency_pct": 69.0, "summer_efficiency_pct": 59.0, "comparative_hot_water_efficiency_pct": 43.0, "output_kw_max": 14.6, "final_year_of_manufacture": 1998, "raw": ["000131", "000007", "0", "2010/Sep/13 17:03", "Burco Maxol", "Burco Maxol", "Microturbo", "50 SRF & 50 MDF", "4120219", "", "1998", "1", "0", "0", "1", "0", "", "", "1", "2", "2", "14.6", "14.6", "", "", "69.0", "59.0", "", "43.0", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 260, "brand_name": "Caradon Ideal", "model_name": "Mexico Slimline", "model_qualifier": "cf40", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 11.72, "final_year_of_manufacture": 1988, "raw": ["000260", "000008", "0", "2010/Sep/13 17:03", "Caradon Ideal", "Caradon Ideal", "Mexico Slimline", "cf40", "4140716", "", "1988", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "11.72", "11.72", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 262, "brand_name": "Caradon Ideal", "model_name": "Mexico Slimline", "model_qualifier": "cf55", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 16.12, "final_year_of_manufacture": 1988, "raw": ["000262", "000008", "0", "2010/Sep/13 17:03", "Caradon Ideal", "Caradon Ideal", "Mexico Slimline", "cf55", "4140718", "", "1988", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "16.12", "16.12", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 264, "brand_name": "Caradon Ideal", "model_name": "Mexico Slimline", "model_qualifier": "rs40", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 11.72, "final_year_of_manufacture": 1988, "raw": ["000264", "000008", "0", "2010/Sep/13 17:03", "Caradon Ideal", "Caradon Ideal", "Mexico Slimline", "rs40", "4140715", "", "1988", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "11.72", "11.72", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 266, "brand_name": "Caradon Ideal", "model_name": "Mexico Slimline", "model_qualifier": "rs55", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 16.12, "final_year_of_manufacture": 1988, "raw": ["000266", "000008", "0", "2010/Sep/13 17:03", "Caradon Ideal", "Caradon Ideal", "Mexico Slimline", "rs55", "4140717", "", "1988", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "16.12", "16.12", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 268, "brand_name": "Caradon Ideal", "model_name": "Mexico Slimline 2", "model_qualifier": "cf40", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 11.72, "final_year_of_manufacture": 1988, "raw": ["000268", "000008", "0", "2010/Sep/13 17:03", "Caradon Ideal", "Caradon Ideal", "Mexico Slimline 2", "cf40", "4142108", "", "1988", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "11.72", "11.72", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 269, "brand_name": "Caradon Ideal", "model_name": "Mexico Slimline 2", "model_qualifier": "cf55", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 16.12, "final_year_of_manufacture": 1988, "raw": ["000269", "000008", "0", "2010/Sep/13 17:03", "Caradon Ideal", "Caradon Ideal", "Mexico Slimline 2", "cf55", "4142109", "", "1988", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "16.12", "16.12", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 270, "brand_name": "Caradon Ideal", "model_name": "Mexico Slimline 2", "model_qualifier": "rs40", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 11.72, "final_year_of_manufacture": 1988, "raw": ["000270", "000008", "0", "2010/Sep/13 17:03", "Caradon Ideal", "Caradon Ideal", "Mexico Slimline 2", "rs40", "4142110", "", "1988", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "11.72", "11.72", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 271, "brand_name": "Caradon Ideal", "model_name": "Mexico Slimline 2", "model_qualifier": "rs55", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 16.12, "final_year_of_manufacture": 1988, "raw": ["000271", "000008", "0", "2010/Sep/13 17:03", "Caradon Ideal", "Caradon Ideal", "Mexico Slimline 2", "rs55", "4142111", "", "1988", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "16.12", "16.12", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 272, "brand_name": "Caradon Ideal", "model_name": "Mexico Super", "model_qualifier": "cf100", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 29.3, "final_year_of_manufacture": 1988, "raw": ["000272", "000008", "0", "2010/Sep/13 17:03", "Caradon Ideal", "Caradon Ideal", "Mexico Super", "cf100", "4140746", "", "1988", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "29.3", "29.3", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 273, "brand_name": "Caradon Ideal", "model_name": "Mexico Super", "model_qualifier": "cf125", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 36.64, "final_year_of_manufacture": 1988, "raw": ["000273", "000008", "0", "2010/Sep/13 17:03", "Caradon Ideal", "Caradon Ideal", "Mexico Super", "cf125", "4140748", "", "1988", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "36.64", "36.64", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 275, "brand_name": "Caradon Ideal", "model_name": "Mexico Super", "model_qualifier": "cf30/40", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 11.72, "final_year_of_manufacture": 1988, "raw": ["000275", "000008", "0", "2010/Sep/13 17:03", "Caradon Ideal", "Caradon Ideal", "Mexico Super", "cf30/40", "4141526", "", "1988", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "11.72", "11.72", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 277, "brand_name": "Caradon Ideal", "model_name": "Mexico Super", "model_qualifier": "cf40", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 11.72, "final_year_of_manufacture": 1988, "raw": ["000277", "000008", "0", "2010/Sep/13 17:03", "Caradon Ideal", "Caradon Ideal", "Mexico Super", "cf40", "4141549", "", "1988", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "11.72", "11.72", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 278, "brand_name": "Caradon Ideal", "model_name": "Mexico Super", "model_qualifier": "cf40/60", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 17.6, "final_year_of_manufacture": 1988, "raw": ["000278", "000008", "0", "2010/Sep/13 17:03", "Caradon Ideal", "Caradon Ideal", "Mexico Super", "cf40/60", "4141527", "", "1988", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "17.6", "17.6", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 280, "brand_name": "Caradon Ideal", "model_name": "Mexico Super", "model_qualifier": "cf55", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 16.12, "final_year_of_manufacture": 1988, "raw": ["000280", "000008", "0", "2010/Sep/13 17:03", "Caradon Ideal", "Caradon Ideal", "Mexico Super", "cf55", "4140764", "", "1988", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "16.12", "16.12", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 281, "brand_name": "Caradon Ideal", "model_name": "Mexico Super", "model_qualifier": "cf65", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 19.05, "final_year_of_manufacture": 1988, "raw": ["000281", "000008", "0", "2010/Sep/13 17:03", "Caradon Ideal", "Caradon Ideal", "Mexico Super", "cf65", "4140740", "", "1988", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "19.05", "19.05", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 282, "brand_name": "Caradon Ideal", "model_name": "Mexico Super", "model_qualifier": "cf75", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 22.0, "final_year_of_manufacture": 1988, "raw": ["000282", "000008", "0", "2010/Sep/13 17:03", "Caradon Ideal", "Caradon Ideal", "Mexico Super", "cf75", "4140742", "", "1988", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "22", "22", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 283, "brand_name": "Caradon Ideal", "model_name": "Mexico Super", "model_qualifier": "cf80", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 23.45, "final_year_of_manufacture": 1988, "raw": ["000283", "000008", "0", "2010/Sep/13 17:03", "Caradon Ideal", "Caradon Ideal", "Mexico Super", "cf80", "4140744", "", "1988", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "23.45", "23.45", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 284, "brand_name": "Caradon Ideal", "model_name": "Mexico Super", "model_qualifier": "rs100", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 29.3, "final_year_of_manufacture": 1988, "raw": ["000284", "000008", "0", "2010/Sep/13 17:03", "Caradon Ideal", "Caradon Ideal", "Mexico Super", "rs100", "4140747", "", "1988", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "29.3", "29.3", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 285, "brand_name": "Caradon Ideal", "model_name": "Mexico Super", "model_qualifier": "rs125", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 36.64, "final_year_of_manufacture": 1988, "raw": ["000285", "000008", "0", "2010/Sep/13 17:03", "Caradon Ideal", "Caradon Ideal", "Mexico Super", "rs125", "4140749", "", "1988", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "36.64", "36.64", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 286, "brand_name": "Caradon Ideal", "model_name": "Mexico Super", "model_qualifier": "rs30/40", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 11.72, "final_year_of_manufacture": 1988, "raw": ["000286", "000008", "0", "2010/Sep/13 17:03", "Caradon Ideal", "Caradon Ideal", "Mexico Super", "rs30/40", "4141524", "", "1988", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "11.72", "11.72", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 287, "brand_name": "Caradon Ideal", "model_name": "Mexico Super", "model_qualifier": "rs40", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 11.72, "final_year_of_manufacture": 1988, "raw": ["000287", "000008", "0", "2010/Sep/13 17:03", "Caradon Ideal", "Caradon Ideal", "Mexico Super", "rs40", "4141547", "", "1988", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "11.72", "11.72", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 289, "brand_name": "Caradon Ideal", "model_name": "Mexico Super", "model_qualifier": "rs40/60", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 17.58, "final_year_of_manufacture": 1988, "raw": ["000289", "000008", "0", "2010/Sep/13 17:03", "Caradon Ideal", "Caradon Ideal", "Mexico Super", "rs40/60", "4141525", "", "1988", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "17.58", "17.58", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 290, "brand_name": "Caradon Ideal", "model_name": "Mexico Super", "model_qualifier": "rs55", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 16.12, "final_year_of_manufacture": 1988, "raw": ["000290", "000008", "0", "2010/Sep/13 17:03", "Caradon Ideal", "Caradon Ideal", "Mexico Super", "rs55", "4140763", "", "1988", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "16.12", "16.12", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 292, "brand_name": "Caradon Ideal", "model_name": "Mexico Super", "model_qualifier": "rs65", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 19.05, "final_year_of_manufacture": 1988, "raw": ["000292", "000008", "0", "2010/Sep/13 17:03", "Caradon Ideal", "Caradon Ideal", "Mexico Super", "rs65", "4140741", "", "1988", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "19.05", "19.05", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 293, "brand_name": "Caradon Ideal", "model_name": "Mexico Super", "model_qualifier": "rs75", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 22.0, "final_year_of_manufacture": 1988, "raw": ["000293", "000008", "0", "2010/Sep/13 17:03", "Caradon Ideal", "Caradon Ideal", "Mexico Super", "rs75", "4140743", "", "1988", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "22", "22", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 294, "brand_name": "Caradon Ideal", "model_name": "Mexico Super", "model_qualifier": "rs80", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 23.45, "final_year_of_manufacture": 1988, "raw": ["000294", "000008", "0", "2010/Sep/13 17:03", "Caradon Ideal", "Caradon Ideal", "Mexico Super", "rs80", "4140745", "", "1988", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "23.45", "23.45", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 413, "brand_name": "Chaffoteaux", "model_name": "Celtic", "model_qualifier": "ff", "winter_efficiency_pct": 71.0, "summer_efficiency_pct": 62.0, "comparative_hot_water_efficiency_pct": 43.2, "output_kw_max": 24.0, "final_year_of_manufacture": 1996, "raw": ["000413", "000010", "0", "2010/Sep/13 17:03", "Chaffoteaux", "Chaffoteaux", "Celtic", "ff", "4798001", "", "1996", "1", "0", "0", "2", "0", "", "", "1", "2", "2", "24", "24", "", "", "71.0", "62.0", "", "43.2", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 414, "brand_name": "Chaffoteaux", "model_name": "Challenger", "model_qualifier": "30bf", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 8.7, "final_year_of_manufacture": 1990, "raw": ["000414", "000010", "0", "2010/Sep/13 17:03", "Chaffoteaux", "Chaffoteaux", "Challenger", "30bf", "4198071", "", "1990", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "8.7", "8.7", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 415, "brand_name": "Chaffoteaux", "model_name": "Challenger", "model_qualifier": "30ff", "winter_efficiency_pct": 73.0, "summer_efficiency_pct": 63.0, "comparative_hot_water_efficiency_pct": 45.9, "output_kw_max": 8.79, "final_year_of_manufacture": 1990, "raw": ["000415", "000010", "0", "2015/Jul/21 14:15", "Chaffoteaux", "Chaffoteaux", "Challenger", "30ff", "4198074", "", "1990", "1", "0", "0", "1", "0", "", "", "1", "2", "2", "8.79", "8.79", "", "", "73.0", "63.0", "", "45.9", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 416, "brand_name": "Chaffoteaux", "model_name": "Challenger", "model_qualifier": "30of", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 9.0, "final_year_of_manufacture": 1990, "raw": ["000416", "000010", "0", "2010/Sep/13 17:03", "Chaffoteaux", "Chaffoteaux", "Challenger", "30of", "4198072", "", "1990", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "9", "9", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 417, "brand_name": "Chaffoteaux", "model_name": "Challenger", "model_qualifier": "40bf", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 11.6, "final_year_of_manufacture": 1990, "raw": ["000417", "000010", "0", "2010/Sep/13 17:03", "Chaffoteaux", "Chaffoteaux", "Challenger", "40bf", "4198075", "", "1990", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "11.6", "11.6", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 418, "brand_name": "Chaffoteaux", "model_name": "Challenger", "model_qualifier": "50ff", "winter_efficiency_pct": 73.0, "summer_efficiency_pct": 63.0, "comparative_hot_water_efficiency_pct": 45.9, "output_kw_max": 14.65, "final_year_of_manufacture": 1990, "raw": ["000418", "000010", "0", "2015/Jul/21 14:15", "Chaffoteaux", "Chaffoteaux", "Challenger", "50ff", "4198077", "", "1990", "1", "0", "0", "1", "0", "", "", "1", "2", "2", "14.65", "14.65", "", "", "73.0", "63.0", "", "45.9", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 419, "brand_name": "Chaffoteaux", "model_name": "Challenger", "model_qualifier": "50of", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 14.6, "final_year_of_manufacture": 1990, "raw": ["000419", "000010", "0", "2010/Sep/13 17:03", "Chaffoteaux", "Chaffoteaux", "Challenger", "50of", "4198076", "", "1990", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "14.6", "14.6", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 420, "brand_name": "Chaffoteaux", "model_name": "Corvec", "model_qualifier": "28bf", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 8.2, "final_year_of_manufacture": 1984, "raw": ["000420", "000010", "0", "2010/Sep/13 17:03", "Chaffoteaux", "Chaffoteaux", "Corvec", "28bf", "4198027", "", "1984", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "8.2", "8.2", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 421, "brand_name": "Chaffoteaux", "model_name": "Corvec", "model_qualifier": "28of", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 8.2, "final_year_of_manufacture": 1984, "raw": ["000421", "000010", "0", "2010/Sep/13 17:03", "Chaffoteaux", "Chaffoteaux", "Corvec", "28of", "4198028", "", "1984", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "8.2", "8.2", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 422, "brand_name": "Chaffoteaux", "model_name": "Corvec", "model_qualifier": "28s", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 8.2, "final_year_of_manufacture": 1984, "raw": ["000422", "000010", "0", "2010/Sep/13 17:03", "Chaffoteaux", "Chaffoteaux", "Corvec", "28s", "4198044", "", "1984", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "8.2", "8.2", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 423, "brand_name": "Chaffoteaux", "model_name": "Corvec", "model_qualifier": "45bf", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 13.2, "final_year_of_manufacture": 1984, "raw": ["000423", "000010", "0", "2010/Sep/13 17:03", "Chaffoteaux", "Chaffoteaux", "Corvec", "45bf", "4198029", "", "1984", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "13.2", "13.2", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 424, "brand_name": "Chaffoteaux", "model_name": "Corvec", "model_qualifier": "45of", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 13.2, "final_year_of_manufacture": 1984, "raw": ["000424", "000010", "0", "2010/Sep/13 17:03", "Chaffoteaux", "Chaffoteaux", "Corvec", "45of", "4198030", "", "1984", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "13.2", "13.2", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 425, "brand_name": "Chaffoteaux", "model_name": "Corvec", "model_qualifier": "45s", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 13.2, "final_year_of_manufacture": 1984, "raw": ["000425", "000010", "0", "2010/Sep/13 17:03", "Chaffoteaux", "Chaffoteaux", "Corvec", "45s", "4198045", "", "1984", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "13.2", "13.2", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 426, "brand_name": "Chaffoteaux", "model_name": "Corvec", "model_qualifier": "48cf", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": null, "final_year_of_manufacture": 1978, "raw": ["000426", "000010", "0", "2010/Sep/13 17:03", "Chaffoteaux", "Chaffoteaux", "Corvec", "48cf", "4198001", "", "1978", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "", "", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 427, "brand_name": "Chaffoteaux", "model_name": "Corvec", "model_qualifier": "64cf", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": null, "final_year_of_manufacture": 1978, "raw": ["000427", "000010", "0", "2010/Sep/13 17:03", "Chaffoteaux", "Chaffoteaux", "Corvec", "64cf", "4198003", "", "1978", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "", "", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 428, "brand_name": "Chaffoteaux", "model_name": "Corvec", "model_qualifier": "80cf", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": null, "final_year_of_manufacture": 1978, "raw": ["000428", "000010", "0", "2010/Sep/13 17:03", "Chaffoteaux", "Chaffoteaux", "Corvec", "80cf", "4198005", "", "1978", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "", "", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 429, "brand_name": "Chaffoteaux", "model_name": "Corvec Maxiflame", "model_qualifier": "2bf", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 17.58, "final_year_of_manufacture": 1979, "raw": ["000429", "000010", "0", "2010/Sep/13 17:03", "Chaffoteaux", "Chaffoteaux", "Corvec Maxiflame", "2bf", "4198046", "", "1979", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "17.58", "17.58", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 433, "brand_name": "Chaffoteaux", "model_name": "Corvec Miniflame", "model_qualifier": "cf", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 8.2, "final_year_of_manufacture": 1977, "raw": ["000433", "000010", "0", "2010/Sep/13 17:03", "Chaffoteaux", "Chaffoteaux", "Corvec Miniflame", "cf", "4198020", "", "1977", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "8.2", "8.2", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 456, "brand_name": "Claudio GR (Vokera)", "model_name": "Excell", "model_qualifier": "80SP", "winter_efficiency_pct": 74.0, "summer_efficiency_pct": 64.0, "comparative_hot_water_efficiency_pct": 44.9, "output_kw_max": 23.7, "final_year_of_manufacture": 1999, "raw": ["000456", "000011", "0", "2010/Sep/13 17:03", "Claudio GR (Vokera)", "Claudio GR (Vokera)", "Excell", "80SP", "4709417", "", "1999", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "23.7", "23.7", "", "", "74.0", "64.0", "", "44.9", "", "3", "", "", "0", "2", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 457, "brand_name": "Vokera", "model_name": "Excell", "model_qualifier": "80E", "winter_efficiency_pct": 73.0, "summer_efficiency_pct": 64.0, "comparative_hot_water_efficiency_pct": 45.0, "output_kw_max": 23.7, "final_year_of_manufacture": 1999, "raw": ["000457", "000011", "0", "2010/Sep/13 17:03", "Vokera", "Vokera", "Excell", "80E", "4709418", "", "1999", "1", "0", "0", "2", "0", "", "", "1", "2", "2", "23.7", "23.7", "", "", "73.0", "64.0", "", "45.0", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 458, "brand_name": "Vokera", "model_name": "Excell", "model_qualifier": "96E", "winter_efficiency_pct": 73.0, "summer_efficiency_pct": 64.0, "comparative_hot_water_efficiency_pct": 45.0, "output_kw_max": 28.0, "final_year_of_manufacture": 1999, "raw": ["000458", "000011", "0", "2010/Sep/13 17:03", "Vokera", "Vokera", "Excell", "96E", "4709414", "", "1999", "1", "0", "0", "2", "0", "", "", "1", "2", "2", "28", "28", "", "", "73.0", "64.0", "", "45.0", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 467, "brand_name": "Vokera", "model_name": "Meteor", "model_qualifier": "V90", "winter_efficiency_pct": 69.0, "summer_efficiency_pct": 59.0, "comparative_hot_water_efficiency_pct": 43.0, "output_kw_max": 26.1, "final_year_of_manufacture": 1999, "raw": ["000467", "000011", "0", "2010/Sep/13 17:03", "Vokera", "Vokera", "Meteor", "V90", "4709420", "", "1999", "1", "0", "0", "1", "0", "", "", "1", "2", "2", "26.1", "26.1", "", "", "69.0", "59.0", "", "43.0", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 468, "brand_name": "Vokera", "model_name": "Meteor", "model_qualifier": "S90", "winter_efficiency_pct": 69.0, "summer_efficiency_pct": 59.0, "comparative_hot_water_efficiency_pct": 43.0, "output_kw_max": 26.1, "final_year_of_manufacture": 1999, "raw": ["000468", "000011", "0", "2010/Sep/13 17:03", "Vokera", "Vokera", "Meteor", "S90", "4709421", "", "1999", "1", "0", "0", "1", "0", "", "", "1", "2", "2", "26.1", "26.1", "", "", "69.0", "59.0", "", "43.0", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 474, "brand_name": "Ferroli", "model_name": "Combi", "model_qualifier": "76ff", "winter_efficiency_pct": 71.0, "summer_efficiency_pct": 62.0, "comparative_hot_water_efficiency_pct": 43.2, "output_kw_max": 22.3, "final_year_of_manufacture": null, "raw": ["000474", "000097", "0", "2010/Sep/13 17:03", "Ferroli", "Ferroli", "Combi", "76ff", "4726703", "", "obsolete", "1", "0", "0", "2", "0", "", "", "1", "2", "2", "22.3", "22.3", "", "", "71.0", "62.0", "", "43.2", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 478, "brand_name": "Ferroli", "model_name": "Roma", "model_qualifier": "55ff", "winter_efficiency_pct": 73.0, "summer_efficiency_pct": 63.0, "comparative_hot_water_efficiency_pct": 45.9, "output_kw_max": 16.0, "final_year_of_manufacture": null, "raw": ["000478", "000097", "0", "2015/Jul/21 14:15", "Ferroli", "Ferroli", "Roma", "55ff", "4126705", "", "obsolete", "1", "0", "0", "1", "0", "", "", "1", "2", "2", "16", "16", "", "", "73.0", "63.0", "", "45.9", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 488, "brand_name": "Ferroli", "model_name": "Xignal", "model_qualifier": "Xignal", "winter_efficiency_pct": 69.0, "summer_efficiency_pct": 59.0, "comparative_hot_water_efficiency_pct": 43.0, "output_kw_max": 27.9, "final_year_of_manufacture": null, "raw": ["000488", "000097", "0", "2010/Sep/13 17:03", "Ferroli", "Ferroli", "Xignal", "Xignal", "", "", "obsolete", "1", "0", "0", "1", "0", "", "", "1", "2", "2", "27.9", "27.9", "", "", "69.0", "59.0", "", "43.0", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 489, "brand_name": "Ferroli", "model_name": "Hawk II", "model_qualifier": "Hawk II", "winter_efficiency_pct": 69.0, "summer_efficiency_pct": 59.0, "comparative_hot_water_efficiency_pct": 43.0, "output_kw_max": 23.3, "final_year_of_manufacture": null, "raw": ["000489", "000097", "0", "2010/Sep/13 17:03", "Ferroli", "Ferroli", "Hawk II", "Hawk II", "", "", "obsolete", "1", "0", "0", "1", "0", "", "", "1", "2", "2", "23.3", "23.3", "", "", "69.0", "59.0", "", "43.0", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 490, "brand_name": "Halstead", "model_name": "30/90Combi", "model_qualifier": "30/90combi", "winter_efficiency_pct": 71.0, "summer_efficiency_pct": 62.0, "comparative_hot_water_efficiency_pct": 43.2, "output_kw_max": 23.4, "final_year_of_manufacture": 1994, "raw": ["000490", "000019", "0", "2010/Sep/13 17:03", "Halstead Boilers", "Halstead", "30/90Combi", "30/90combi", "4728301", "", "1994", "1", "0", "0", "2", "0", "", "", "1", "2", "2", "23.4", "23.4", "", "", "71.0", "62.0", "", "43.2", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 491, "brand_name": "Halstead", "model_name": "Blenheim", "model_qualifier": "15/30", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 8.79, "final_year_of_manufacture": 1995, "raw": ["000491", "000019", "0", "2010/Sep/13 17:03", "Halstead Boilers", "Halstead", "Blenheim", "15/30", "4133320", "", "1995", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "8.79", "8.79", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 492, "brand_name": "Halstead", "model_name": "Blenheim", "model_qualifier": "30/40", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 11.72, "final_year_of_manufacture": 1995, "raw": ["000492", "000019", "0", "2010/Sep/13 17:03", "Halstead Boilers", "Halstead", "Blenheim", "30/40", "4133316", "", "1995", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "11.72", "11.72", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 493, "brand_name": "Halstead", "model_name": "Blenheim", "model_qualifier": "40", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 12.46, "final_year_of_manufacture": 1995, "raw": ["000493", "000019", "0", "2010/Sep/13 17:03", "Halstead Boilers", "Halstead", "Blenheim", "40", "4133305", "", "1995", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "12.46", "12.46", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 494, "brand_name": "Halstead", "model_name": "Blenheim", "model_qualifier": "40/50", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 14.65, "final_year_of_manufacture": 1995, "raw": ["000494", "000019", "0", "2010/Sep/13 17:03", "Halstead Boilers", "Halstead", "Blenheim", "40/50", "4133317", "", "1995", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "14.65", "14.65", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 495, "brand_name": "Halstead", "model_name": "Blenheim", "model_qualifier": "50", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 15.53, "final_year_of_manufacture": 1995, "raw": ["000495", "000019", "0", "2010/Sep/13 17:03", "Halstead Boilers", "Halstead", "Blenheim", "50", "4133306", "", "1995", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "15.53", "15.53", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 496, "brand_name": "Halstead", "model_name": "Blenheim", "model_qualifier": "50/60", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 17.58, "final_year_of_manufacture": 1995, "raw": ["000496", "000019", "0", "2010/Sep/13 17:03", "Halstead Boilers", "Halstead", "Blenheim", "50/60", "4133318", "", "1995", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "17.58", "17.58", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 497, "brand_name": "Halstead", "model_name": "Blenheim", "model_qualifier": "60/75", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 21.98, "final_year_of_manufacture": 1995, "raw": ["000497", "000019", "0", "2010/Sep/13 17:03", "Halstead Boilers", "Halstead", "Blenheim", "60/75", "4133319", "", "1995", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "21.98", "21.98", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 508, "brand_name": "Halstead", "model_name": "40h", "model_qualifier": "", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 12.46, "final_year_of_manufacture": 1986, "raw": ["000508", "000019", "0", "2010/Sep/13 17:03", "Halstead Boilers", "Halstead", "40h", "", "4133301", "", "1986", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "12.46", "12.46", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 509, "brand_name": "Halstead", "model_name": "Balmoral", "model_qualifier": "45f", "winter_efficiency_pct": 73.0, "summer_efficiency_pct": 63.0, "comparative_hot_water_efficiency_pct": 45.9, "output_kw_max": 13.19, "final_year_of_manufacture": 1996, "raw": ["000509", "000019", "0", "2015/Jul/21 14:15", "Halstead Boilers", "Halstead", "Balmoral", "45f", "4133311", "", "1996", "1", "0", "0", "1", "0", "", "", "1", "2", "2", "13.19", "13.19", "", "", "73.0", "63.0", "", "45.9", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 510, "brand_name": "Halstead", "model_name": "50h", "model_qualifier": "", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 15.53, "final_year_of_manufacture": 1986, "raw": ["000510", "000019", "0", "2010/Sep/13 17:03", "Halstead Boilers", "Halstead", "50h", "", "4133302", "", "1986", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "15.53", "15.53", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 511, "brand_name": "Halstead", "model_name": "Balmoral", "model_qualifier": "65f", "winter_efficiency_pct": 73.0, "summer_efficiency_pct": 63.0, "comparative_hot_water_efficiency_pct": 45.9, "output_kw_max": 19.05, "final_year_of_manufacture": 1996, "raw": ["000511", "000019", "0", "2015/Jul/21 14:15", "Halstead Boilers", "Halstead", "Balmoral", "65f", "4133312", "", "1996", "1", "0", "0", "1", "0", "", "", "1", "2", "2", "19.05", "19.05", "", "", "73.0", "63.0", "", "45.9", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 512, "brand_name": "Halstead", "model_name": "Triocombi", "model_qualifier": "triocombi", "winter_efficiency_pct": 71.0, "summer_efficiency_pct": 62.0, "comparative_hot_water_efficiency_pct": 43.2, "output_kw_max": 23.4, "final_year_of_manufacture": 1994, "raw": ["000512", "000019", "0", "2010/Sep/13 17:03", "Halstead Boilers", "Halstead", "Triocombi", "triocombi", "4728301", "", "1994", "1", "0", "0", "2", "0", "", "", "1", "2", "2", "23.4", "23.4", "", "", "71.0", "62.0", "", "43.2", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 513, "brand_name": "Halstead", "model_name": "Quattro", "model_qualifier": "Quattro", "winter_efficiency_pct": 71.0, "summer_efficiency_pct": 62.0, "comparative_hot_water_efficiency_pct": 43.2, "output_kw_max": 23.4, "final_year_of_manufacture": 1997, "raw": ["000513", "000019", "0", "2010/Sep/13 17:03", "Halstead Boilers", "Halstead", "Quattro", "Quattro", "", "", "1997", "1", "0", "0", "2", "0", "", "", "1", "2", "2", "23.4", "23.4", "", "", "71.0", "62.0", "", "43.2", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 520, "brand_name": "Halstead", "model_name": "Buckingham II", "model_qualifier": "BF40", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 11.7, "final_year_of_manufacture": 1996, "raw": ["000520", "000019", "0", "2010/Sep/13 17:03", "Halstead Boilers", "Halstead", "Buckingham II", "BF40", "", "", "1996", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "11.7", "11.7", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 521, "brand_name": "Halstead", "model_name": "Buckingham II", "model_qualifier": "BF50", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 14.7, "final_year_of_manufacture": 1996, "raw": ["000521", "000019", "0", "2010/Sep/13 17:03", "Halstead Boilers", "Halstead", "Buckingham II", "BF50", "", "", "1996", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "14.7", "14.7", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 522, "brand_name": "Halstead", "model_name": "Buckingham II", "model_qualifier": "BF60", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 17.6, "final_year_of_manufacture": 1996, "raw": ["000522", "000019", "0", "2010/Sep/13 17:03", "Halstead Boilers", "Halstead", "Buckingham II", "BF60", "", "", "1996", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "17.6", "17.6", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 523, "brand_name": "Halstead", "model_name": "Buckingham II", "model_qualifier": "BF70", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 20.5, "final_year_of_manufacture": 1996, "raw": ["000523", "000019", "0", "2010/Sep/13 17:03", "Halstead Boilers", "Halstead", "Buckingham II", "BF70", "", "", "1996", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "20.5", "20.5", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 524, "brand_name": "Halstead", "model_name": "Buckingham II", "model_qualifier": "BF80", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 23.4, "final_year_of_manufacture": 1996, "raw": ["000524", "000019", "0", "2010/Sep/13 17:03", "Halstead Boilers", "Halstead", "Buckingham II", "BF80", "", "", "1996", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "23.4", "23.4", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 525, "brand_name": "Halstead", "model_name": "Buckingham II", "model_qualifier": "BF100", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 27.8, "final_year_of_manufacture": 1996, "raw": ["000525", "000019", "0", "2010/Sep/13 17:03", "Halstead Boilers", "Halstead", "Buckingham II", "BF100", "", "", "1996", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "27.8", "27.8", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 526, "brand_name": "Halstead", "model_name": "Buckingham II", "model_qualifier": "CF40", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 11.7, "final_year_of_manufacture": 1996, "raw": ["000526", "000019", "0", "2010/Sep/13 17:03", "Halstead Boilers", "Halstead", "Buckingham II", "CF40", "", "", "1996", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "11.7", "11.7", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 527, "brand_name": "Halstead", "model_name": "Buckingham II", "model_qualifier": "CF50", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 14.7, "final_year_of_manufacture": 1996, "raw": ["000527", "000019", "0", "2010/Sep/13 17:03", "Halstead Boilers", "Halstead", "Buckingham II", "CF50", "", "", "1996", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "14.7", "14.7", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 528, "brand_name": "Halstead", "model_name": "Buckingham II", "model_qualifier": "CF60", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 17.6, "final_year_of_manufacture": 1996, "raw": ["000528", "000019", "0", "2010/Sep/13 17:03", "Halstead Boilers", "Halstead", "Buckingham II", "CF60", "", "", "1996", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "17.6", "17.6", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 529, "brand_name": "Halstead", "model_name": "Buckingham II", "model_qualifier": "CF70", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 20.5, "final_year_of_manufacture": 1996, "raw": ["000529", "000019", "0", "2010/Sep/13 17:03", "Halstead Boilers", "Halstead", "Buckingham II", "CF70", "", "", "1996", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "20.5", "20.5", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 530, "brand_name": "Halstead", "model_name": "Buckingham II", "model_qualifier": "CF80", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 23.4, "final_year_of_manufacture": 1996, "raw": ["000530", "000019", "0", "2010/Sep/13 17:03", "Halstead Boilers", "Halstead", "Buckingham II", "CF80", "", "", "1996", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "23.4", "23.4", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 531, "brand_name": "Halstead", "model_name": "Buckingham II", "model_qualifier": "CF100", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 27.8, "final_year_of_manufacture": 1996, "raw": ["000531", "000019", "0", "2010/Sep/13 17:03", "Halstead Boilers", "Halstead", "Buckingham II", "CF100", "", "", "1996", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "27.8", "27.8", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 533, "brand_name": "Hepworth Heating", "model_name": "Economy", "model_qualifier": "30F", "winter_efficiency_pct": 73.0, "summer_efficiency_pct": 63.0, "comparative_hot_water_efficiency_pct": 45.9, "output_kw_max": 8.79, "final_year_of_manufacture": 1992, "raw": ["000533", "000020", "0", "2015/Jul/21 14:15", "Hepworth Heating", "Hepworth Heating", "Economy", "30F", "4131905", "", "1992", "1", "0", "0", "1", "0", "", "", "1", "2", "2", "8.79", "8.79", "", "", "73.0", "63.0", "", "45.9", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 535, "brand_name": "Hepworth Heating", "model_name": "Economy", "model_qualifier": "40F", "winter_efficiency_pct": 73.0, "summer_efficiency_pct": 63.0, "comparative_hot_water_efficiency_pct": 45.9, "output_kw_max": 11.72, "final_year_of_manufacture": 1992, "raw": ["000535", "000020", "0", "2015/Jul/21 14:15", "Hepworth Heating", "Hepworth Heating", "Economy", "40F", "4131906", "", "1992", "1", "0", "0", "1", "0", "", "", "1", "2", "2", "11.72", "11.72", "", "", "73.0", "63.0", "", "45.9", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 537, "brand_name": "Hepworth Heating", "model_name": "Economy", "model_qualifier": "50F", "winter_efficiency_pct": 73.0, "summer_efficiency_pct": 63.0, "comparative_hot_water_efficiency_pct": 45.9, "output_kw_max": 14.65, "final_year_of_manufacture": 1992, "raw": ["000537", "000020", "0", "2015/Jul/21 14:15", "Hepworth Heating", "Hepworth Heating", "Economy", "50F", "4131907", "", "1992", "1", "0", "0", "1", "0", "", "", "1", "2", "2", "14.65", "14.65", "", "", "73.0", "63.0", "", "45.9", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 549, "brand_name": "Glow-worm", "model_name": "Spacesaver Complheat", "model_qualifier": "60", "winter_efficiency_pct": 73.0, "summer_efficiency_pct": 63.0, "comparative_hot_water_efficiency_pct": 45.9, "output_kw_max": 17.59, "final_year_of_manufacture": 1997, "raw": ["000549", "000207", "0", "2015/Jul/21 14:15", "Hepworth Heating", "Glow-worm", "Spacesaver Complheat", "60", "4131945", "", "1997", "1", "0", "0", "1", "0", "", "", "1", "2", "2", "17.59", "17.59", "", "", "73.0", "63.0", "", "45.9", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 550, "brand_name": "Glow-worm", "model_name": "Spacesaver Complheat", "model_qualifier": "70", "winter_efficiency_pct": 73.0, "summer_efficiency_pct": 63.0, "comparative_hot_water_efficiency_pct": 45.9, "output_kw_max": 20.52, "final_year_of_manufacture": 1997, "raw": ["000550", "000207", "0", "2015/Jul/21 14:15", "Hepworth Heating", "Glow-worm", "Spacesaver Complheat", "70", "4131946", "", "1997", "1", "0", "0", "1", "0", "", "", "1", "2", "2", "20.52", "20.52", "", "", "73.0", "63.0", "", "45.9", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 551, "brand_name": "Glow-worm", "model_name": "Spacesaver Kfb", "model_qualifier": "20", "winter_efficiency_pct": 69.0, "summer_efficiency_pct": 59.0, "comparative_hot_water_efficiency_pct": 43.0, "output_kw_max": 5.86, "final_year_of_manufacture": 1998, "raw": ["000551", "000207", "0", "2010/Sep/13 17:03", "Hepworth Heating", "Glow-worm", "Spacesaver Kfb", "20", "4131922", "", "1998", "1", "0", "0", "1", "0", "", "", "1", "2", "2", "5.86", "5.86", "", "", "69.0", "59.0", "", "43.0", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 552, "brand_name": "Glow-worm", "model_name": "Spacesaver Kfb", "model_qualifier": "60", "winter_efficiency_pct": 69.0, "summer_efficiency_pct": 59.0, "comparative_hot_water_efficiency_pct": 43.0, "output_kw_max": 17.59, "final_year_of_manufacture": 1997, "raw": ["000552", "000207", "0", "2010/Sep/13 17:03", "Hepworth Heating", "Glow-worm", "Spacesaver Kfb", "60", "4131911", "", "1997", "1", "0", "0", "1", "0", "", "", "1", "2", "2", "17.59", "17.59", "", "", "69.0", "59.0", "", "43.0", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 553, "brand_name": "Glow-worm", "model_name": "Spacesaver Kfb", "model_qualifier": "70", "winter_efficiency_pct": 69.0, "summer_efficiency_pct": 59.0, "comparative_hot_water_efficiency_pct": 43.0, "output_kw_max": 20.52, "final_year_of_manufacture": 1997, "raw": ["000553", "000207", "0", "2010/Sep/13 17:03", "Hepworth Heating", "Glow-worm", "Spacesaver Kfb", "70", "4131912", "", "1997", "1", "0", "0", "1", "0", "", "", "1", "2", "2", "20.52", "20.52", "", "", "69.0", "59.0", "", "43.0", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 571, "brand_name": "Glow-worm", "model_name": "Economy Plus", "model_qualifier": "75B", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": null, "final_year_of_manufacture": 1997, "raw": ["000571", "000207", "0", "2010/Sep/13 17:03", "Hepworth Heating", "Glow-worm", "Economy Plus", "75B", "4131962", "", "1997", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "", "", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 574, "brand_name": "Malvern", "model_name": "70", "model_qualifier": "NG", "winter_efficiency_pct": 91.0, "summer_efficiency_pct": 74.0, "comparative_hot_water_efficiency_pct": 53.7, "output_kw_max": null, "final_year_of_manufacture": 1995, "raw": ["000574", "000023", "0", "2010/Sep/13 17:03", "Malvern Boilers", "Malvern", "70", "NG", "", "", "1995", "1", "0", "0", "1", "0", "", "", "2", "2", "2", "", "", "", "", "91.0", "74.0", "", "53.7", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0001", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 579, "brand_name": "Potterton Myson", "model_name": "FRS 52", "model_qualifier": "", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": null, "final_year_of_manufacture": 1974, "raw": ["000579", "000005", "0", "2010/Sep/13 17:03", "Potterton Myson", "Potterton Myson", "FRS 52", "", "41 595 96", "", "1974", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "", "", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 581, "brand_name": "Potterton International Heating", "model_name": "C40", "model_qualifier": "c40/12", "winter_efficiency_pct": 56.0, "summer_efficiency_pct": 46.0, "comparative_hot_water_efficiency_pct": 33.5, "output_kw_max": 11.1, "final_year_of_manufacture": 1972, "raw": ["000581", "000005", "0", "2010/Sep/13 17:03", "Potterton International Heating", "Potterton International Heating", "C40", "c40/12", "4159502", "", "1972", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "11.1", "11.1", "", "", "56.0", "46.0", "", "33.5", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 582, "brand_name": "Potterton Myson", "model_name": "C40", "model_qualifier": "c40/12", "winter_efficiency_pct": 56.0, "summer_efficiency_pct": 46.0, "comparative_hot_water_efficiency_pct": 33.5, "output_kw_max": 11.1, "final_year_of_manufacture": 1976, "raw": ["000582", "000005", "0", "2010/Sep/13 17:03", "Potterton Myson", "Potterton Myson", "C40", "c40/12", "4159586", "", "1976", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "11.1", "11.1", "", "", "56.0", "46.0", "", "33.5", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 589, "brand_name": "Potterton International Heating", "model_name": "C50", "model_qualifier": "c50/15", "winter_efficiency_pct": 56.0, "summer_efficiency_pct": 46.0, "comparative_hot_water_efficiency_pct": 33.5, "output_kw_max": 13.8, "final_year_of_manufacture": 1976, "raw": ["000589", "000005", "0", "2010/Sep/13 17:03", "Potterton International Heating", "Potterton International Heating", "C50", "c50/15", "4159564", "", "1976", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "13.8", "13.8", "", "", "56.0", "46.0", "", "33.5", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 590, "brand_name": "Potterton Myson", "model_name": "C55", "model_qualifier": "c55/16", "winter_efficiency_pct": 56.0, "summer_efficiency_pct": 46.0, "comparative_hot_water_efficiency_pct": 33.5, "output_kw_max": 16.1, "final_year_of_manufacture": 1976, "raw": ["000590", "000005", "0", "2010/Sep/13 17:03", "Potterton Myson", "Potterton Myson", "C55", "c55/16", "4160105", "", "1976", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "16.1", "16.1", "", "", "56.0", "46.0", "", "33.5", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 593, "brand_name": "Potterton International Heating", "model_name": "C70", "model_qualifier": "c70/21", "winter_efficiency_pct": 56.0, "summer_efficiency_pct": 46.0, "comparative_hot_water_efficiency_pct": 33.5, "output_kw_max": 19.6, "final_year_of_manufacture": 1976, "raw": ["000593", "000005", "0", "2010/Sep/13 17:03", "Potterton International Heating", "Potterton International Heating", "C70", "c70/21", "4159565", "", "1976", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "19.6", "19.6", "", "", "56.0", "46.0", "", "33.5", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 595, "brand_name": "Potterton Myson", "model_name": "C80", "model_qualifier": "c80/23", "winter_efficiency_pct": 56.0, "summer_efficiency_pct": 46.0, "comparative_hot_water_efficiency_pct": 33.5, "output_kw_max": 22.6, "final_year_of_manufacture": 1976, "raw": ["000595", "000005", "0", "2010/Sep/13 17:03", "Potterton Myson", "Potterton Myson", "C80", "c80/23", "4159505", "", "1976", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "22.6", "22.6", "", "", "56.0", "46.0", "", "33.5", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 596, "brand_name": "Potterton International Heating", "model_name": "C80", "model_qualifier": "c80/23", "winter_efficiency_pct": 56.0, "summer_efficiency_pct": 46.0, "comparative_hot_water_efficiency_pct": 33.5, "output_kw_max": 22.6, "final_year_of_manufacture": 1976, "raw": ["000596", "000005", "0", "2010/Sep/13 17:03", "Potterton International Heating", "Potterton International Heating", "C80", "c80/23", "4159566", "", "1976", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "22.6", "22.6", "", "", "56.0", "46.0", "", "33.5", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 598, "brand_name": "Potterton Myson", "model_name": "C95", "model_qualifier": "c95/28", "winter_efficiency_pct": 56.0, "summer_efficiency_pct": 46.0, "comparative_hot_water_efficiency_pct": 33.5, "output_kw_max": 26.7, "final_year_of_manufacture": 1972, "raw": ["000598", "000005", "0", "2010/Sep/13 17:03", "Potterton Myson", "Potterton Myson", "C95", "c95/28", "4159567", "", "1972", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "26.7", "26.7", "", "", "56.0", "46.0", "", "33.5", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 599, "brand_name": "Potterton International Heating", "model_name": "C95", "model_qualifier": "c95/28", "winter_efficiency_pct": 56.0, "summer_efficiency_pct": 46.0, "comparative_hot_water_efficiency_pct": 33.5, "output_kw_max": 26.7, "final_year_of_manufacture": 1972, "raw": ["000599", "000005", "0", "2010/Sep/13 17:03", "Potterton International Heating", "Potterton International Heating", "C95", "c95/28", "4159506", "", "1972", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "26.7", "26.7", "", "", "56.0", "46.0", "", "33.5", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 600, "brand_name": "Potterton International Heating", "model_name": "Fireside", "model_qualifier": "35/51", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": null, "final_year_of_manufacture": null, "raw": ["000600", "000005", "0", "2010/Sep/13 17:03", "Potterton International Heating", "Potterton International Heating", "Fireside", "35/51", "4459015", "", "obsolete", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "", "", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 601, "brand_name": "Potterton International Heating", "model_name": "Fireside", "model_qualifier": "50", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": null, "final_year_of_manufacture": 1972, "raw": ["000601", "000005", "0", "2010/Sep/13 17:03", "Potterton International Heating", "Potterton International Heating", "Fireside", "50", "4459002", "", "1972", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "", "", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 602, "brand_name": "Potterton International Heating", "model_name": "Fireside", "model_qualifier": "50tg", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": null, "final_year_of_manufacture": null, "raw": ["000602", "000005", "0", "2010/Sep/13 17:03", "Potterton International Heating", "Potterton International Heating", "Fireside", "50tg", "4459001", "", "obsolete", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "", "", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 604, "brand_name": "Potterton International Heating", "model_name": "Fireside", "model_qualifier": "51", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": null, "final_year_of_manufacture": 1976, "raw": ["000604", "000005", "0", "2010/Sep/13 17:03", "Potterton International Heating", "Potterton International Heating", "Fireside", "51", "4459004", "", "1976", "1", "4", "1", "1", "0", "", "", "1", "1", "1", "", "", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "0", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 605, "brand_name": "Potterton Myson", "model_name": "Fireside", "model_qualifier": "52", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": null, "final_year_of_manufacture": 1976, "raw": ["000605", "000005", "0", "2010/Sep/13 17:03", "Potterton Myson", "Potterton Myson", "Fireside", "52", "4459006", "", "1976", "1", "4", "0", "1", "0", "", "", "1", "1", "1", "", "", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 606, "brand_name": "Potterton International Heating", "model_name": "Fireside", "model_qualifier": "52", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": null, "final_year_of_manufacture": 1976, "raw": ["000606", "000005", "0", "2010/Sep/13 17:03", "Potterton International Heating", "Potterton International Heating", "Fireside", "52", "4459005", "", "1976", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "", "", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 607, "brand_name": "Potterton International Heating", "model_name": "Fireside", "model_qualifier": "fs44lbe", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": null, "final_year_of_manufacture": 1972, "raw": ["000607", "000005", "0", "2010/Sep/13 17:03", "Potterton International Heating", "Potterton International Heating", "Fireside", "fs44lbe", "4159507", "", "1972", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "", "", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 608, "brand_name": "Potterton International Heating", "model_name": "Fireside", "model_qualifier": "super", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": null, "final_year_of_manufacture": 1986, "raw": ["000608", "000005", "0", "2010/Sep/13 17:03", "Potterton International Heating", "Potterton International Heating", "Fireside", "super", "4459013", "", "1986", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "", "", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 609, "brand_name": "Potterton International Heating", "model_name": "Flamingo", "model_qualifier": "50of", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 14.65, "final_year_of_manufacture": 1986, "raw": ["000609", "000005", "0", "2010/Sep/13 17:03", "Potterton International Heating", "Potterton International Heating", "Flamingo", "50of", "4160118", "", "1986", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "14.65", "14.65", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 610, "brand_name": "Potterton Myson", "model_name": "Flamingo", "model_qualifier": "cf20-30", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 8.8, "final_year_of_manufacture": 1986, "raw": ["000610", "000005", "0", "2010/Sep/13 17:03", "Potterton Myson", "Potterton Myson", "Flamingo", "cf20-30", "4160133", "", "1986", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "8.8", "8.8", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 611, "brand_name": "Potterton International Heating", "model_name": "Flamingo", "model_qualifier": "cf20/35", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 10.26, "final_year_of_manufacture": 1995, "raw": ["000611", "000005", "0", "2010/Sep/13 17:03", "Potterton International Heating", "Potterton International Heating", "Flamingo", "cf20/35", "4160559", "", "1995", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "10.26", "10.26", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 612, "brand_name": "Potterton International Heating", "model_name": "Flamingo", "model_qualifier": "cf35/50", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 14.65, "final_year_of_manufacture": 1995, "raw": ["000612", "000005", "0", "2010/Sep/13 17:03", "Potterton International Heating", "Potterton International Heating", "Flamingo", "cf35/50", "4160560", "", "1995", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "14.65", "14.65", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 613, "brand_name": "Potterton Myson", "model_name": "Flamingo", "model_qualifier": "rs20-30", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 8.8, "final_year_of_manufacture": 1986, "raw": ["000613", "000005", "0", "2010/Sep/13 17:03", "Potterton Myson", "Potterton Myson", "Flamingo", "rs20-30", "4160123", "", "1986", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "8.8", "8.8", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 614, "brand_name": "Potterton International Heating", "model_name": "Flamingo", "model_qualifier": "rs20/35", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 10.26, "final_year_of_manufacture": 1995, "raw": ["000614", "000005", "0", "2010/Sep/13 17:03", "Potterton International Heating", "Potterton International Heating", "Flamingo", "rs20/35", "4160557", "", "1995", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "10.26", "10.26", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 615, "brand_name": "Potterton Myson", "model_name": "Flamingo", "model_qualifier": "rs35/50", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 14.65, "final_year_of_manufacture": 1995, "raw": ["000615", "000005", "0", "2010/Sep/13 17:03", "Potterton Myson", "Potterton Myson", "Flamingo", "rs35/50", "4160558", "", "1995", "1", "2", "1", "1", "0", "", "", "1", "2", "1", "14.65", "14.65", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 616, "brand_name": "Potterton Myson", "model_name": "Flamingo", "model_qualifier": "rs40", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 11.7, "final_year_of_manufacture": 1986, "raw": ["000616", "000005", "0", "2010/Sep/13 17:03", "Potterton Myson", "Potterton Myson", "Flamingo", "rs40", "4160125", "", "1986", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "11.7", "11.7", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 617, "brand_name": "Potterton International Heating", "model_name": "Flamingo", "model_qualifier": "rs50", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 13.5, "final_year_of_manufacture": 1981, "raw": ["000617", "000005", "0", "2010/Sep/13 17:03", "Potterton International Heating", "Potterton International Heating", "Flamingo", "rs50", "4160114", "", "1981", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "13.5", "13.5", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 618, "brand_name": "Potterton Myson", "model_name": "Flamingo", "model_qualifier": "rs50s", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 14.7, "final_year_of_manufacture": 1986, "raw": ["000618", "000005", "0", "2010/Sep/13 17:03", "Potterton Myson", "Potterton Myson", "Flamingo", "rs50s", "4160143", "", "1986", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "14.7", "14.7", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 619, "brand_name": "Potterton Myson", "model_name": "Flamingo 2", "model_qualifier": "cf20/30", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 8.8, "final_year_of_manufacture": 1986, "raw": ["000619", "000005", "0", "2010/Sep/13 17:03", "Potterton Myson", "Potterton Myson", "Flamingo 2", "cf20/30", "4160516", "", "1986", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "8.8", "8.8", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 620, "brand_name": "Potterton Myson", "model_name": "Flamingo 2", "model_qualifier": "cf50", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 14.65, "final_year_of_manufacture": 1986, "raw": ["000620", "000005", "0", "2010/Sep/13 17:03", "Potterton Myson", "Potterton Myson", "Flamingo 2", "cf50", "4160514", "", "1986", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "14.65", "14.65", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 621, "brand_name": "Potterton Myson", "model_name": "Flamingo 2", "model_qualifier": "rs20/30", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 8.8, "final_year_of_manufacture": 1989, "raw": ["000621", "000005", "0", "2010/Sep/13 17:03", "Potterton Myson", "Potterton Myson", "Flamingo 2", "rs20/30", "4160515", "", "1989", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "8.8", "8.8", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 622, "brand_name": "Potterton Myson", "model_name": "Flamingo 2", "model_qualifier": "rs40", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 11.7, "final_year_of_manufacture": 1986, "raw": ["000622", "000005", "0", "2010/Sep/13 17:03", "Potterton Myson", "Potterton Myson", "Flamingo 2", "rs40", "4160512", "", "1986", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "11.7", "11.7", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 623, "brand_name": "Potterton Myson", "model_name": "Flamingo 2", "model_qualifier": "rs50", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 14.7, "final_year_of_manufacture": 1989, "raw": ["000623", "000005", "0", "2010/Sep/13 17:03", "Potterton Myson", "Potterton Myson", "Flamingo 2", "rs50", "4160513", "", "1989", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "14.7", "14.7", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 624, "brand_name": "Potterton Myson", "model_name": "Kingfisher", "model_qualifier": "cf100", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 29.3, "final_year_of_manufacture": 1986, "raw": ["000624", "000005", "0", "2010/Sep/13 17:03", "Potterton Myson", "Potterton Myson", "Kingfisher", "cf100", "4160142", "", "1986", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "29.3", "29.3", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 625, "brand_name": "Potterton International Heating", "model_name": "Kingfisher", "model_qualifier": "cf125", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 36.6, "final_year_of_manufacture": 1998, "raw": ["000625", "000005", "0", "2010/Sep/13 17:03", "Potterton International Heating", "Potterton International Heating", "Kingfisher", "cf125", "4160115", "", "1998", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "36.6", "36.6", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 626, "brand_name": "Potterton International Heating", "model_name": "Kingfisher", "model_qualifier": "cf150", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 44.0, "final_year_of_manufacture": 1998, "raw": ["000626", "000005", "0", "2010/Sep/13 17:03", "Potterton International Heating", "Potterton International Heating", "Kingfisher", "cf150", "4160116", "", "1998", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "44", "44", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 627, "brand_name": "Potterton Myson", "model_name": "Kingfisher", "model_qualifier": "cf40", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 11.7, "final_year_of_manufacture": 1983, "raw": ["000627", "000005", "0", "2010/Sep/13 17:03", "Potterton Myson", "Potterton Myson", "Kingfisher", "cf40", "4160157", "", "1983", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "11.7", "11.7", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 628, "brand_name": "Potterton Myson", "model_name": "Kingfisher", "model_qualifier": "cf40a", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 11.7, "final_year_of_manufacture": 1986, "raw": ["000628", "000005", "0", "2010/Sep/13 17:03", "Potterton Myson", "Potterton Myson", "Kingfisher", "cf40a", "4160160", "", "1986", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "11.7", "11.7", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 629, "brand_name": "Potterton International Heating", "model_name": "Kingfisher", "model_qualifier": "cf45", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 13.2, "final_year_of_manufacture": 1980, "raw": ["000629", "000005", "0", "2010/Sep/13 17:03", "Potterton International Heating", "Potterton International Heating", "Kingfisher", "cf45", "4160107", "", "1980", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "13.2", "13.2", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 630, "brand_name": "Potterton Myson", "model_name": "Kingfisher", "model_qualifier": "cf50", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 14.6, "final_year_of_manufacture": 1985, "raw": ["000630", "000005", "0", "2010/Sep/13 17:03", "Potterton Myson", "Potterton Myson", "Kingfisher", "cf50", "4160158", "", "1985", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "14.6", "14.6", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 631, "brand_name": "Potterton Myson", "model_name": "Kingfisher", "model_qualifier": "cf50a", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 14.6, "final_year_of_manufacture": 1986, "raw": ["000631", "000005", "0", "2010/Sep/13 17:03", "Potterton Myson", "Potterton Myson", "Kingfisher", "cf50a", "4160161", "", "1986", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "14.6", "14.6", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 632, "brand_name": "Potterton International Heating", "model_name": "Kingfisher", "model_qualifier": "cf55", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 16.1, "final_year_of_manufacture": 1980, "raw": ["000632", "000005", "0", "2010/Sep/13 17:03", "Potterton International Heating", "Potterton International Heating", "Kingfisher", "cf55", "4150108", "", "1980", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "16.1", "16.1", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 633, "brand_name": "Potterton Myson", "model_name": "Kingfisher", "model_qualifier": "cf60", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 17.5, "final_year_of_manufacture": 1986, "raw": ["000633", "000005", "0", "2010/Sep/13 17:03", "Potterton Myson", "Potterton Myson", "Kingfisher", "cf60", "4160156", "", "1986", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "17.5", "17.5", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 634, "brand_name": "Potterton Myson", "model_name": "Kingfisher", "model_qualifier": "cf80", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 23.4, "final_year_of_manufacture": 1986, "raw": ["000634", "000005", "0", "2010/Sep/13 17:03", "Potterton Myson", "Potterton Myson", "Kingfisher", "cf80", "4160139", "", "1986", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "23.4", "23.4", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 635, "brand_name": "Potterton Myson", "model_name": "Kingfisher", "model_qualifier": "rs100", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 29.3, "final_year_of_manufacture": 1986, "raw": ["000635", "000005", "0", "2010/Sep/13 17:03", "Potterton Myson", "Potterton Myson", "Kingfisher", "rs100", "4160159", "", "1986", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "29.3", "29.3", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 636, "brand_name": "Potterton International Heating", "model_name": "Kingfisher", "model_qualifier": "rs50", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 13.5, "final_year_of_manufacture": 1986, "raw": ["000636", "000005", "0", "2010/Sep/13 17:03", "Potterton International Heating", "Potterton International Heating", "Kingfisher", "rs50", "4160149", "", "1986", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "13.5", "13.5", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 637, "brand_name": "Potterton Myson", "model_name": "Kingfisher", "model_qualifier": "rs60", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 17.6, "final_year_of_manufacture": 1986, "raw": ["000637", "000005", "0", "2010/Sep/13 17:03", "Potterton Myson", "Potterton Myson", "Kingfisher", "rs60", "4160137", "", "1986", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "17.6", "17.6", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 638, "brand_name": "Potterton Myson", "model_name": "Kingfisher", "model_qualifier": "rs80", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 23.4, "final_year_of_manufacture": 1986, "raw": ["000638", "000005", "0", "2010/Sep/13 17:03", "Potterton Myson", "Potterton Myson", "Kingfisher", "rs80", "4160141", "", "1986", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "23.4", "23.4", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 639, "brand_name": "Potterton International Heating", "model_name": "Kingfisher 2", "model_qualifier": "cf100", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 29.3, "final_year_of_manufacture": 1998, "raw": ["000639", "000005", "0", "2010/Sep/13 17:03", "Potterton International Heating", "Potterton International Heating", "Kingfisher 2", "cf100", "4160711", "", "1998", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "29.3", "29.3", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 640, "brand_name": "Potterton International Heating", "model_name": "Kingfisher 2", "model_qualifier": "cf125", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 36.6, "final_year_of_manufacture": 1998, "raw": ["000640", "000005", "0", "2010/Sep/13 17:03", "Potterton International Heating", "Potterton International Heating", "Kingfisher 2", "cf125", "4160715", "", "1998", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "36.6", "36.6", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 641, "brand_name": "Potterton Myson", "model_name": "Kingfisher 2", "model_qualifier": "cf150", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 44.0, "final_year_of_manufacture": 1998, "raw": ["000641", "000005", "0", "2010/Sep/13 17:03", "Potterton Myson", "Potterton Myson", "Kingfisher 2", "cf150", "4160716", "", "1998", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "44", "44", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 642, "brand_name": "Potterton International Heating", "model_name": "Kingfisher 2", "model_qualifier": "cf220", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 64.5, "final_year_of_manufacture": 1998, "raw": ["000642", "000005", "0", "2010/Sep/13 17:03", "Potterton International Heating", "Potterton International Heating", "Kingfisher 2", "cf220", "", "", "1998", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "64.5", "64.5", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 643, "brand_name": "Potterton International Heating", "model_name": "Kingfisher 2", "model_qualifier": "cf40", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 11.7, "final_year_of_manufacture": 1998, "raw": ["000643", "000005", "0", "2010/Sep/13 17:03", "Potterton International Heating", "Potterton International Heating", "Kingfisher 2", "cf40", "4160707", "", "1998", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "11.7", "11.7", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 644, "brand_name": "Potterton International Heating", "model_name": "Kingfisher 2", "model_qualifier": "cf50", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 14.6, "final_year_of_manufacture": 1998, "raw": ["000644", "000005", "0", "2010/Sep/13 17:03", "Potterton International Heating", "Potterton International Heating", "Kingfisher 2", "cf50", "4160708", "", "1998", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "14.6", "14.6", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 645, "brand_name": "Potterton International Heating", "model_name": "Kingfisher 2", "model_qualifier": "cf60", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 17.5, "final_year_of_manufacture": 1998, "raw": ["000645", "000005", "0", "2010/Sep/13 17:03", "Potterton International Heating", "Potterton International Heating", "Kingfisher 2", "cf60", "4160709", "", "1998", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "17.5", "17.5", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 646, "brand_name": "Potterton International Heating", "model_name": "Kingfisher 2", "model_qualifier": "cf80", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 23.4, "final_year_of_manufacture": 1998, "raw": ["000646", "000005", "0", "2010/Sep/13 17:03", "Potterton International Heating", "Potterton International Heating", "Kingfisher 2", "cf80", "4160710", "", "1998", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "23.4", "23.4", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 647, "brand_name": "Potterton International Heating", "model_name": "Kingfisher 2", "model_qualifier": "rs100", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 29.3, "final_year_of_manufacture": 1998, "raw": ["000647", "000005", "0", "2010/Sep/13 17:03", "Potterton International Heating", "Potterton International Heating", "Kingfisher 2", "rs100", "4160721", "", "1998", "1", "1", "1", "1", "0", "", "", "1", "2", "1", "29.3", "29.3", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 648, "brand_name": "Potterton Myson", "model_name": "Kingfisher 2", "model_qualifier": "rs40", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 11.7, "final_year_of_manufacture": 1998, "raw": ["000648", "000005", "0", "2010/Sep/13 17:03", "Potterton Myson", "Potterton Myson", "Kingfisher 2", "rs40", "4160717", "", "1998", "1", "1", "1", "1", "0", "", "", "1", "2", "1", "11.7", "11.7", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 649, "brand_name": "Potterton International Heating", "model_name": "Kingfisher 2", "model_qualifier": "rs50", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 14.7, "final_year_of_manufacture": 1998, "raw": ["000649", "000005", "0", "2010/Sep/13 17:03", "Potterton International Heating", "Potterton International Heating", "Kingfisher 2", "rs50", "4160718", "", "1998", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "14.7", "14.7", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 650, "brand_name": "Potterton International Heating", "model_name": "Kingfisher 2", "model_qualifier": "rs60", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 17.6, "final_year_of_manufacture": 1998, "raw": ["000650", "000005", "0", "2010/Sep/13 17:03", "Potterton International Heating", "Potterton International Heating", "Kingfisher 2", "rs60", "4160719", "", "1998", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "17.6", "17.6", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 651, "brand_name": "Potterton International Heating", "model_name": "Kingfisher 2", "model_qualifier": "rs80", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 23.5, "final_year_of_manufacture": 1998, "raw": ["000651", "000005", "0", "2010/Sep/13 17:03", "Potterton International Heating", "Potterton International Heating", "Kingfisher 2", "rs80", "4160720", "", "1998", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "23.5", "23.5", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 652, "brand_name": "Potterton International Heating", "model_name": "Lynx", "model_qualifier": "2", "winter_efficiency_pct": 71.0, "summer_efficiency_pct": 61.0, "comparative_hot_water_efficiency_pct": 42.8, "output_kw_max": 23.45, "final_year_of_manufacture": 1995, "raw": ["000652", "000005", "0", "2010/Sep/13 17:03", "Potterton International Heating", "Potterton International Heating", "Lynx", "2", "4759008", "", "1995", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "23.45", "23.45", "", "", "71.0", "61.0", "", "42.8", "", "3", "", "", "0", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 653, "brand_name": "Potterton International Heating", "model_name": "Lynx", "model_qualifier": "electronic", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 57.0, "comparative_hot_water_efficiency_pct": 39.7, "output_kw_max": 23.45, "final_year_of_manufacture": 1972, "raw": ["000653", "000005", "0", "2010/Sep/13 17:03", "Potterton International Heating", "Potterton International Heating", "Lynx", "electronic", "4759002", "", "1972", "1", "0", "0", "2", "0", "", "", "1", "2", "1", "23.45", "23.45", "", "", "66.0", "57.0", "", "39.7", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 654, "brand_name": "Potterton International Heating", "model_name": "Netaheat Electronic", "model_qualifier": "16/22e", "winter_efficiency_pct": 69.0, "summer_efficiency_pct": 59.0, "comparative_hot_water_efficiency_pct": 43.0, "output_kw_max": 22.0, "final_year_of_manufacture": 1983, "raw": ["000654", "000005", "0", "2010/Sep/13 17:03", "Potterton International Heating", "Potterton International Heating", "Netaheat Electronic", "16/22e", "4160163", "", "1983", "1", "0", "0", "1", "0", "", "", "1", "2", "2", "22", "22", "", "", "69.0", "59.0", "", "43.0", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 655, "brand_name": "Potterton International Heating", "model_name": "Netaheat", "model_qualifier": "mk2f10-16bf", "winter_efficiency_pct": 69.0, "summer_efficiency_pct": 59.0, "comparative_hot_water_efficiency_pct": 43.0, "output_kw_max": 16.1, "final_year_of_manufacture": 1984, "raw": ["000655", "000005", "0", "2010/Sep/13 17:03", "Potterton International Heating", "Potterton International Heating", "Netaheat", "mk2f10-16bf", "4160134", "", "1984", "1", "0", "0", "1", "0", "", "", "1", "2", "2", "16.1", "16.1", "", "", "69.0", "59.0", "", "43.0", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 656, "brand_name": "Potterton International Heating", "model_name": "Netaheat", "model_qualifier": "mk2f16-22bf", "winter_efficiency_pct": 69.0, "summer_efficiency_pct": 59.0, "comparative_hot_water_efficiency_pct": 43.0, "output_kw_max": 22.0, "final_year_of_manufacture": 1984, "raw": ["000656", "000005", "0", "2010/Sep/13 17:03", "Potterton International Heating", "Potterton International Heating", "Netaheat", "mk2f16-22bf", "4160135", "", "1984", "1", "0", "0", "1", "0", "", "", "1", "2", "2", "22", "22", "", "", "69.0", "59.0", "", "43.0", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 657, "brand_name": "Potterton International Heating", "model_name": "Netaheat Electronic", "model_qualifier": "10/16", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 16.0, "final_year_of_manufacture": 1988, "raw": ["000657", "000005", "0", "2010/Sep/13 17:03", "Potterton International Heating", "Potterton International Heating", "Netaheat Electronic", "10/16", "4160167", "", "1988", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "16", "16", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 658, "brand_name": "Potterton Myson", "model_name": "Netaheat Electronic", "model_qualifier": "10/16e", "winter_efficiency_pct": 69.0, "summer_efficiency_pct": 59.0, "comparative_hot_water_efficiency_pct": 43.0, "output_kw_max": 16.1, "final_year_of_manufacture": 1988, "raw": ["000658", "000005", "0", "2010/Sep/13 17:03", "Potterton Myson", "Potterton Myson", "Netaheat Electronic", "10/16e", "4160162", "", "1988", "1", "0", "0", "1", "0", "", "", "1", "2", "2", "16.1", "16.1", "", "", "69.0", "59.0", "", "43.0", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 659, "brand_name": "Potterton Myson", "model_name": "Netaheat Electronic", "model_qualifier": "16/22", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 22.0, "final_year_of_manufacture": 1988, "raw": ["000659", "000005", "0", "2010/Sep/13 17:03", "Potterton Myson", "Potterton Myson", "Netaheat Electronic", "16/22", "4160166", "", "1988", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "22", "22", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 660, "brand_name": "Potterton International Heating", "model_name": "Netaheat Electronic", "model_qualifier": "6/10", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 10.3, "final_year_of_manufacture": 1988, "raw": ["000660", "000005", "0", "2010/Sep/13 17:03", "Potterton International Heating", "Potterton International Heating", "Netaheat Electronic", "6/10", "4160168", "", "1988", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "10.3", "10.3", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 676, "brand_name": "Potterton Myson", "model_name": "Rs38/11", "model_qualifier": "rs38/11", "winter_efficiency_pct": 56.0, "summer_efficiency_pct": 46.0, "comparative_hot_water_efficiency_pct": 33.5, "output_kw_max": 10.56, "final_year_of_manufacture": 1976, "raw": ["000676", "000005", "0", "2010/Sep/13 17:03", "Potterton Myson", "Potterton Myson", "Rs38/11", "rs38/11", "4159529", "", "1976", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "10.56", "10.56", "", "", "56.0", "46.0", "", "33.5", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 677, "brand_name": "Potterton Myson", "model_name": "Rs50/15", "model_qualifier": "rs50/15", "winter_efficiency_pct": 56.0, "summer_efficiency_pct": 46.0, "comparative_hot_water_efficiency_pct": 33.5, "output_kw_max": 13.5, "final_year_of_manufacture": 1976, "raw": ["000677", "000005", "0", "2010/Sep/13 17:03", "Potterton Myson", "Potterton Myson", "Rs50/15", "rs50/15", "4159530", "", "1976", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "13.5", "13.5", "", "", "56.0", "46.0", "", "33.5", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 678, "brand_name": "Potterton Myson", "model_name": "Rs70/21", "model_qualifier": "rs70/21", "winter_efficiency_pct": 56.0, "summer_efficiency_pct": 46.0, "comparative_hot_water_efficiency_pct": 33.5, "output_kw_max": 19.3, "final_year_of_manufacture": 1973, "raw": ["000678", "000005", "0", "2010/Sep/13 17:03", "Potterton Myson", "Potterton Myson", "Rs70/21", "rs70/21", "4159531", "", "1973", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "19.3", "19.3", "", "", "56.0", "46.0", "", "33.5", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 679, "brand_name": "Potterton International Heating", "model_name": "Rs70/21", "model_qualifier": "rs70/21", "winter_efficiency_pct": 56.0, "summer_efficiency_pct": 46.0, "comparative_hot_water_efficiency_pct": 33.5, "output_kw_max": 19.3, "final_year_of_manufacture": 1979, "raw": ["000679", "000005", "0", "2010/Sep/13 17:03", "Potterton International Heating", "Potterton International Heating", "Rs70/21", "rs70/21", "4159501", "", "1979", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "19.3", "19.3", "", "", "56.0", "46.0", "", "33.5", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 680, "brand_name": "Potterton International Heating", "model_name": "Rs90/26", "model_qualifier": "rs90/26", "winter_efficiency_pct": 56.0, "summer_efficiency_pct": 46.0, "comparative_hot_water_efficiency_pct": 33.5, "output_kw_max": 28.2, "final_year_of_manufacture": 1976, "raw": ["000680", "000005", "0", "2010/Sep/13 17:03", "Potterton International Heating", "Potterton International Heating", "Rs90/26", "rs90/26", "4159532", "", "1976", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "28.2", "28.2", "", "", "56.0", "46.0", "", "33.5", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 682, "brand_name": "Potterton International Heating", "model_name": "Tattler", "model_qualifier": "rs46", "winter_efficiency_pct": 56.0, "summer_efficiency_pct": 46.0, "comparative_hot_water_efficiency_pct": 33.5, "output_kw_max": 13.5, "final_year_of_manufacture": 1979, "raw": ["000682", "000005", "0", "2010/Sep/13 17:03", "Potterton International Heating", "Potterton International Heating", "Tattler", "rs46", "4160109", "", "1979", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "13.5", "13.5", "", "", "56.0", "46.0", "", "33.5", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 696, "brand_name": "Myson Combustion Products", "model_name": "Velaire Vitesse", "model_qualifier": "40/50 B", "winter_efficiency_pct": 70.0, "summer_efficiency_pct": 58.0, "comparative_hot_water_efficiency_pct": 42.6, "output_kw_max": 14.65, "final_year_of_manufacture": 1997, "raw": ["000696", "000005", "0", "2010/Sep/13 17:03", "Myson Combustion Products", "Myson Combustion Products", "Velaire Vitesse", "40/50 B", "", "", "1997", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "11.72", "14.65", "", "", "70.0", "58.0", "", "42.6", "", "3", "", "", "0", "0", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 697, "brand_name": "Myson Combustion Products", "model_name": "Velaire Vitesse", "model_qualifier": "50/60 B", "winter_efficiency_pct": 70.0, "summer_efficiency_pct": 58.0, "comparative_hot_water_efficiency_pct": 42.6, "output_kw_max": 17.58, "final_year_of_manufacture": 1997, "raw": ["000697", "000005", "0", "2010/Sep/13 17:03", "Myson Combustion Products", "Myson Combustion Products", "Velaire Vitesse", "50/60 B", "", "", "1997", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "14.65", "17.58", "", "", "70.0", "58.0", "", "42.6", "", "3", "", "", "0", "0", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 698, "brand_name": "Myson Combustion Products", "model_name": "Velaire Vitesse", "model_qualifier": "60/80 B", "winter_efficiency_pct": 70.0, "summer_efficiency_pct": 58.0, "comparative_hot_water_efficiency_pct": 42.6, "output_kw_max": 23.45, "final_year_of_manufacture": 1997, "raw": ["000698", "000005", "0", "2010/Sep/13 17:03", "Myson Combustion Products", "Myson Combustion Products", "Velaire Vitesse", "60/80 B", "", "", "1997", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "17.58", "23.45", "", "", "70.0", "58.0", "", "42.6", "", "3", "", "", "0", "0", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 699, "brand_name": "Myson Combustion Products", "model_name": "Velaire Vitesse", "model_qualifier": "80/100 B", "winter_efficiency_pct": 70.0, "summer_efficiency_pct": 58.0, "comparative_hot_water_efficiency_pct": 42.6, "output_kw_max": 29.31, "final_year_of_manufacture": 1997, "raw": ["000699", "000005", "0", "2010/Sep/13 17:03", "Myson Combustion Products", "Myson Combustion Products", "Velaire Vitesse", "80/100 B", "", "", "1997", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "23.45", "29.31", "", "", "70.0", "58.0", "", "42.6", "", "3", "", "", "0", "0", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 700, "brand_name": "Myson Combustion Products", "model_name": "Velaire Vitesse", "model_qualifier": "100/130 B", "winter_efficiency_pct": 70.0, "summer_efficiency_pct": 58.0, "comparative_hot_water_efficiency_pct": 42.6, "output_kw_max": 38.1, "final_year_of_manufacture": 1998, "raw": ["000700", "000005", "0", "2010/Sep/13 17:03", "Myson Combustion Products", "Myson Combustion Products", "Velaire Vitesse", "100/130 B", "", "", "1998", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "29.3", "38.1", "", "", "70.0", "58.0", "", "42.6", "", "3", "", "", "0", "0", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 701, "brand_name": "Myson Combustion Products", "model_name": "Velaire Vitesse", "model_qualifier": "130/170 B", "winter_efficiency_pct": 70.0, "summer_efficiency_pct": 58.0, "comparative_hot_water_efficiency_pct": 42.6, "output_kw_max": 49.8, "final_year_of_manufacture": 1998, "raw": ["000701", "000005", "0", "2010/Sep/13 17:03", "Myson Combustion Products", "Myson Combustion Products", "Velaire Vitesse", "130/170 B", "", "", "1998", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "38.1", "49.8", "", "", "70.0", "58.0", "", "42.6", "", "3", "", "", "0", "0", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 702, "brand_name": "Myson Combustion Products", "model_name": "Velaire Vitesse", "model_qualifier": "40/50 C", "winter_efficiency_pct": 70.0, "summer_efficiency_pct": 58.0, "comparative_hot_water_efficiency_pct": 42.6, "output_kw_max": 14.65, "final_year_of_manufacture": 1997, "raw": ["000702", "000005", "0", "2010/Sep/13 17:03", "Myson Combustion Products", "Myson Combustion Products", "Velaire Vitesse", "40/50 C", "", "", "1997", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "11.72", "14.65", "", "", "70.0", "58.0", "", "42.6", "", "3", "", "", "0", "0", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 703, "brand_name": "Myson Combustion Products", "model_name": "Velaire Vitesse", "model_qualifier": "50/60 C", "winter_efficiency_pct": 70.0, "summer_efficiency_pct": 58.0, "comparative_hot_water_efficiency_pct": 42.6, "output_kw_max": 17.58, "final_year_of_manufacture": 1997, "raw": ["000703", "000005", "0", "2010/Sep/13 17:03", "Myson Combustion Products", "Myson Combustion Products", "Velaire Vitesse", "50/60 C", "", "", "1997", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "14.65", "17.58", "", "", "70.0", "58.0", "", "42.6", "", "3", "", "", "0", "0", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 704, "brand_name": "Myson Combustion Products", "model_name": "Velaire Vitesse", "model_qualifier": "60/80 C", "winter_efficiency_pct": 70.0, "summer_efficiency_pct": 58.0, "comparative_hot_water_efficiency_pct": 42.6, "output_kw_max": 23.45, "final_year_of_manufacture": 1997, "raw": ["000704", "000005", "0", "2010/Sep/13 17:03", "Myson Combustion Products", "Myson Combustion Products", "Velaire Vitesse", "60/80 C", "", "", "1997", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "17.58", "23.45", "", "", "70.0", "58.0", "", "42.6", "", "3", "", "", "0", "0", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 705, "brand_name": "Myson Combustion Products", "model_name": "Velaire Vitesse", "model_qualifier": "80/100 C", "winter_efficiency_pct": 70.0, "summer_efficiency_pct": 58.0, "comparative_hot_water_efficiency_pct": 42.6, "output_kw_max": 29.31, "final_year_of_manufacture": 1997, "raw": ["000705", "000005", "0", "2010/Sep/13 17:03", "Myson Combustion Products", "Myson Combustion Products", "Velaire Vitesse", "80/100 C", "", "", "1997", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "23.45", "29.31", "", "", "70.0", "58.0", "", "42.6", "", "3", "", "", "0", "0", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 706, "brand_name": "Myson Combustion Products", "model_name": "Velaire Vitesse", "model_qualifier": "100/130 C", "winter_efficiency_pct": 70.0, "summer_efficiency_pct": 58.0, "comparative_hot_water_efficiency_pct": 42.6, "output_kw_max": 38.1, "final_year_of_manufacture": 1998, "raw": ["000706", "000005", "0", "2010/Sep/13 17:03", "Myson Combustion Products", "Myson Combustion Products", "Velaire Vitesse", "100/130 C", "", "", "1998", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "29.3", "38.1", "", "", "70.0", "58.0", "", "42.6", "", "3", "", "", "0", "0", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 707, "brand_name": "Myson Combustion Products", "model_name": "Velaire Vitesse", "model_qualifier": "130/170 C", "winter_efficiency_pct": 70.0, "summer_efficiency_pct": 58.0, "comparative_hot_water_efficiency_pct": 42.6, "output_kw_max": 49.8, "final_year_of_manufacture": 1998, "raw": ["000707", "000005", "0", "2010/Sep/13 17:03", "Myson Combustion Products", "Myson Combustion Products", "Velaire Vitesse", "130/170 C", "", "", "1998", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "38.1", "49.8", "", "", "70.0", "58.0", "", "42.6", "", "3", "", "", "0", "0", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 708, "brand_name": "Myson Combustion Products", "model_name": "Velaire Vitesse", "model_qualifier": "170/250 C", "winter_efficiency_pct": 70.0, "summer_efficiency_pct": 58.0, "comparative_hot_water_efficiency_pct": 42.6, "output_kw_max": null, "final_year_of_manufacture": 1997, "raw": ["000708", "000005", "0", "2010/Sep/13 17:03", "Myson Combustion Products", "Myson Combustion Products", "Velaire Vitesse", "170/250 C", "", "", "1997", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "49.8", ">70kW", "", "", "70.0", "58.0", "", "42.6", "", "3", "", "", "0", "0", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 710, "brand_name": "Potterton International Heating", "model_name": "BOA", "model_qualifier": "68", "winter_efficiency_pct": 65.0, "summer_efficiency_pct": 53.0, "comparative_hot_water_efficiency_pct": 38.9, "output_kw_max": 19.9, "final_year_of_manufacture": null, "raw": ["000710", "000005", "0", "2010/Sep/13 17:03", "Potterton International Heating", "Potterton International Heating", "BOA", "68", "", "", "obsolete", "4", "0", "0", "1", "0", "", "", "1", "2", "2", "19.9", "19.9", "", "", "65.0", "53.0", "", "38.9", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 711, "brand_name": "Potterton International Heating", "model_name": "BOA", "model_qualifier": "148", "winter_efficiency_pct": 65.0, "summer_efficiency_pct": 53.0, "comparative_hot_water_efficiency_pct": 38.9, "output_kw_max": 36.0, "final_year_of_manufacture": null, "raw": ["000711", "000005", "0", "2010/Sep/13 17:03", "Potterton International Heating", "Potterton International Heating", "BOA", "148", "", "", "obsolete", "4", "0", "0", "1", "0", "", "", "1", "2", "2", "36", "36", "", "", "65.0", "53.0", "", "38.9", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 713, "brand_name": "Myson Combustion Products", "model_name": "Wallflame", "model_qualifier": "60", "winter_efficiency_pct": 65.0, "summer_efficiency_pct": 53.0, "comparative_hot_water_efficiency_pct": 38.9, "output_kw_max": 17.6, "final_year_of_manufacture": 1980, "raw": ["000713", "000005", "0", "2010/Sep/13 17:03", "Myson Combustion Products", "Myson Combustion Products", "Wallflame", "60", "", "", "1980", "4", "0", "0", "1", "0", "", "", "1", "1", "1", "17.6", "17.6", "", "", "65.0", "53.0", "", "38.9", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 714, "brand_name": "Potterton International Heating", "model_name": "KOA", "model_qualifier": "60/18 SN", "winter_efficiency_pct": 65.0, "summer_efficiency_pct": 53.0, "comparative_hot_water_efficiency_pct": 38.9, "output_kw_max": 17.6, "final_year_of_manufacture": null, "raw": ["000714", "000005", "0", "2010/Sep/13 17:03", "Potterton International Heating", "Potterton International Heating", "KOA", "60/18 SN", "", "", "obsolete", "4", "0", "0", "1", "0", "", "", "1", "2", "2", "17.6", "17.6", "", "", "65.0", "53.0", "", "38.9", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 715, "brand_name": "Potterton International Heating", "model_name": "KOA", "model_qualifier": "75/22 SN", "winter_efficiency_pct": 65.0, "summer_efficiency_pct": 53.0, "comparative_hot_water_efficiency_pct": 38.9, "output_kw_max": 22.0, "final_year_of_manufacture": null, "raw": ["000715", "000005", "0", "2010/Sep/13 17:03", "Potterton International Heating", "Potterton International Heating", "KOA", "75/22 SN", "", "", "obsolete", "4", "0", "0", "1", "0", "", "", "1", "2", "2", "22", "22", "", "", "65.0", "53.0", "", "38.9", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 716, "brand_name": "Potterton International Heating", "model_name": "KOA", "model_qualifier": "90/26 SN", "winter_efficiency_pct": 65.0, "summer_efficiency_pct": 53.0, "comparative_hot_water_efficiency_pct": 38.9, "output_kw_max": 26.4, "final_year_of_manufacture": null, "raw": ["000716", "000005", "0", "2010/Sep/13 17:03", "Potterton International Heating", "Potterton International Heating", "KOA", "90/26 SN", "", "", "obsolete", "4", "0", "0", "1", "0", "", "", "1", "2", "2", "26.4", "26.4", "", "", "65.0", "53.0", "", "38.9", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 717, "brand_name": "Myson Combustion Products", "model_name": "Wallflame", "model_qualifier": "80", "winter_efficiency_pct": 65.0, "summer_efficiency_pct": 53.0, "comparative_hot_water_efficiency_pct": 38.9, "output_kw_max": 23.4, "final_year_of_manufacture": 1980, "raw": ["000717", "000005", "0", "2010/Sep/13 17:03", "Myson Combustion Products", "Myson Combustion Products", "Wallflame", "80", "", "", "1980", "4", "0", "0", "1", "0", "", "", "1", "1", "1", "23.4", "23.4", "", "", "65.0", "53.0", "", "38.9", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 731, "brand_name": "Saunier Duval", "model_name": "500", "model_qualifier": "30b", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 8.79, "final_year_of_manufacture": 1992, "raw": ["000731", "000020", "0", "2010/Sep/13 17:03", "Saunier Duval", "Saunier Duval", "500", "30b", "4192002", "", "1992", "1", "2", "0", "1", "0", "", "", "1", "2", "1", "8.79", "8.79", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 732, "brand_name": "Saunier Duval", "model_name": "500", "model_qualifier": "30c", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 8.79, "final_year_of_manufacture": 1992, "raw": ["000732", "000020", "0", "2010/Sep/13 17:03", "Saunier Duval", "Saunier Duval", "500", "30c", "4192007", "", "1992", "1", "2", "0", "1", "0", "", "", "1", "1", "1", "8.79", "8.79", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 733, "brand_name": "Saunier Duval", "model_name": "500", "model_qualifier": "30f", "winter_efficiency_pct": 69.0, "summer_efficiency_pct": 59.0, "comparative_hot_water_efficiency_pct": 43.0, "output_kw_max": 8.79, "final_year_of_manufacture": 1992, "raw": ["000733", "000020", "0", "2010/Sep/13 17:03", "Saunier Duval", "Saunier Duval", "500", "30f", "4192011", "", "1992", "1", "2", "0", "1", "0", "", "", "1", "2", "2", "8.79", "8.79", "", "", "69.0", "59.0", "", "43.0", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 734, "brand_name": "Saunier Duval", "model_name": "500", "model_qualifier": "40b", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 11.72, "final_year_of_manufacture": 1992, "raw": ["000734", "000020", "0", "2010/Sep/13 17:03", "Saunier Duval", "Saunier Duval", "500", "40b", "4192003", "", "1992", "1", "2", "0", "1", "0", "", "", "1", "2", "1", "11.72", "11.72", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 735, "brand_name": "Saunier Duval", "model_name": "500", "model_qualifier": "40c", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 11.72, "final_year_of_manufacture": 1992, "raw": ["000735", "000020", "0", "2010/Sep/13 17:03", "Saunier Duval", "Saunier Duval", "500", "40c", "4192008", "", "1992", "1", "2", "0", "1", "0", "", "", "1", "1", "1", "11.72", "11.72", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 736, "brand_name": "Saunier Duval", "model_name": "500", "model_qualifier": "40f", "winter_efficiency_pct": 69.0, "summer_efficiency_pct": 59.0, "comparative_hot_water_efficiency_pct": 43.0, "output_kw_max": 11.72, "final_year_of_manufacture": 1992, "raw": ["000736", "000020", "0", "2010/Sep/13 17:03", "Saunier Duval", "Saunier Duval", "500", "40f", "4192012", "", "1992", "1", "2", "0", "1", "0", "", "", "1", "2", "2", "11.72", "11.72", "", "", "69.0", "59.0", "", "43.0", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 737, "brand_name": "Saunier Duval", "model_name": "500", "model_qualifier": "50b", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 14.65, "final_year_of_manufacture": 1992, "raw": ["000737", "000020", "0", "2010/Sep/13 17:03", "Saunier Duval", "Saunier Duval", "500", "50b", "4192004", "", "1992", "1", "2", "0", "1", "0", "", "", "1", "2", "1", "14.65", "14.65", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 738, "brand_name": "Saunier Duval", "model_name": "500", "model_qualifier": "50c", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 14.65, "final_year_of_manufacture": 1992, "raw": ["000738", "000020", "0", "2010/Sep/13 17:03", "Saunier Duval", "Saunier Duval", "500", "50c", "4192009", "", "1992", "1", "2", "0", "1", "0", "", "", "1", "1", "1", "14.65", "14.65", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 739, "brand_name": "Saunier Duval", "model_name": "500", "model_qualifier": "50f", "winter_efficiency_pct": 69.0, "summer_efficiency_pct": 59.0, "comparative_hot_water_efficiency_pct": 43.0, "output_kw_max": 14.65, "final_year_of_manufacture": 1992, "raw": ["000739", "000020", "0", "2010/Sep/13 17:03", "Saunier Duval", "Saunier Duval", "500", "50f", "4192013", "", "1992", "1", "2", "0", "1", "0", "", "", "1", "2", "2", "14.65", "14.65", "", "", "69.0", "59.0", "", "43.0", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 740, "brand_name": "Saunier Duval", "model_name": "500", "model_qualifier": "60b", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 17.59, "final_year_of_manufacture": 1992, "raw": ["000740", "000020", "0", "2010/Sep/13 17:03", "Saunier Duval", "Saunier Duval", "500", "60b", "4192005", "", "1992", "1", "2", "0", "1", "0", "", "", "1", "2", "1", "17.59", "17.59", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 741, "brand_name": "Saunier Duval", "model_name": "500", "model_qualifier": "60c", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 17.59, "final_year_of_manufacture": 1992, "raw": ["000741", "000020", "0", "2010/Sep/13 17:03", "Saunier Duval", "Saunier Duval", "500", "60c", "4192010", "", "1992", "1", "2", "0", "1", "0", "", "", "1", "1", "1", "17.59", "17.59", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 742, "brand_name": "Saunier Duval", "model_name": "500", "model_qualifier": "60f", "winter_efficiency_pct": 69.0, "summer_efficiency_pct": 59.0, "comparative_hot_water_efficiency_pct": 43.0, "output_kw_max": 17.59, "final_year_of_manufacture": 1992, "raw": ["000742", "000020", "0", "2010/Sep/13 17:03", "Saunier Duval", "Saunier Duval", "500", "60f", "4192014", "", "1992", "1", "2", "0", "1", "0", "", "", "1", "2", "2", "17.59", "17.59", "", "", "69.0", "59.0", "", "43.0", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 743, "brand_name": "Saunier Duval", "model_name": "500", "model_qualifier": "80b", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 23.45, "final_year_of_manufacture": 1992, "raw": ["000743", "000020", "0", "2010/Sep/13 17:03", "Saunier Duval", "Saunier Duval", "500", "80b", "4192006", "", "1992", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "23.45", "23.45", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 744, "brand_name": "Saunier Duval", "model_name": "Sd", "model_qualifier": "623", "winter_efficiency_pct": 71.0, "summer_efficiency_pct": 62.0, "comparative_hot_water_efficiency_pct": 43.2, "output_kw_max": 23.3, "final_year_of_manufacture": null, "raw": ["000744", "000206", "0", "2010/Sep/13 17:03", "Saunier Duval", "Saunier Duval", "Sd", "623", "4792001", "", "obsolete", "1", "0", "0", "2", "0", "", "", "1", "2", "2", "23.3", "23.3", "", "", "71.0", "62.0", "", "43.2", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 745, "brand_name": "Saunier Duval", "model_name": "System 400", "model_qualifier": "30", "winter_efficiency_pct": 69.0, "summer_efficiency_pct": 59.0, "comparative_hot_water_efficiency_pct": 43.0, "output_kw_max": 8.8, "final_year_of_manufacture": null, "raw": ["000745", "000206", "0", "2010/Sep/13 17:03", "Saunier Duval", "Saunier Duval", "System 400", "30", "4192017", "", "obsolete", "1", "0", "0", "1", "0", "", "", "1", "2", "2", "8.8", "8.8", "", "", "69.0", "59.0", "", "43.0", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 746, "brand_name": "Saunier Duval", "model_name": "System 400", "model_qualifier": "40", "winter_efficiency_pct": 69.0, "summer_efficiency_pct": 59.0, "comparative_hot_water_efficiency_pct": 43.0, "output_kw_max": 11.7, "final_year_of_manufacture": null, "raw": ["000746", "000206", "0", "2010/Sep/13 17:03", "Saunier Duval", "Saunier Duval", "System 400", "40", "4192018", "", "obsolete", "1", "0", "0", "1", "0", "", "", "1", "2", "2", "11.7", "11.7", "", "", "69.0", "59.0", "", "43.0", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 747, "brand_name": "Saunier Duval", "model_name": "System 400", "model_qualifier": "55", "winter_efficiency_pct": 69.0, "summer_efficiency_pct": 59.0, "comparative_hot_water_efficiency_pct": 43.0, "output_kw_max": 16.1, "final_year_of_manufacture": null, "raw": ["000747", "000206", "0", "2010/Sep/13 17:03", "Saunier Duval", "Saunier Duval", "System 400", "55", "4192019", "", "obsolete", "1", "0", "0", "1", "0", "", "", "1", "2", "2", "16.1", "16.1", "", "", "69.0", "59.0", "", "43.0", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 748, "brand_name": "Saunier Duval", "model_name": "System 400", "model_qualifier": "65", "winter_efficiency_pct": 69.0, "summer_efficiency_pct": 59.0, "comparative_hot_water_efficiency_pct": 43.0, "output_kw_max": 19.1, "final_year_of_manufacture": null, "raw": ["000748", "000206", "0", "2010/Sep/13 17:03", "Saunier Duval", "Saunier Duval", "System 400", "65", "4192020", "", "obsolete", "1", "0", "0", "1", "0", "", "", "1", "2", "2", "19.1", "19.1", "", "", "69.0", "59.0", "", "43.0", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 749, "brand_name": "Saunier Duval", "model_name": "System 400", "model_qualifier": "80", "winter_efficiency_pct": 69.0, "summer_efficiency_pct": 59.0, "comparative_hot_water_efficiency_pct": 43.0, "output_kw_max": 23.4, "final_year_of_manufacture": null, "raw": ["000749", "000206", "0", "2010/Sep/13 17:03", "Saunier Duval", "Saunier Duval", "System 400", "80", "4192021", "", "obsolete", "1", "0", "0", "1", "0", "", "", "1", "2", "2", "23.4", "23.4", "", "", "69.0", "59.0", "", "43.0", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 750, "brand_name": "Saunier Duval", "model_name": "Thelia", "model_qualifier": "23", "winter_efficiency_pct": 71.0, "summer_efficiency_pct": 62.0, "comparative_hot_water_efficiency_pct": 43.2, "output_kw_max": 23.0, "final_year_of_manufacture": null, "raw": ["000750", "000206", "0", "2010/Sep/13 17:03", "Saunier Duval", "Saunier Duval", "Thelia", "23", "", "", "obsolete", "1", "0", "0", "2", "0", "", "", "1", "2", "2", "23", "23", "", "", "71.0", "62.0", "", "43.2", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 751, "brand_name": "Saunier Duval", "model_name": "Thelia", "model_qualifier": "23E", "winter_efficiency_pct": 71.0, "summer_efficiency_pct": 62.0, "comparative_hot_water_efficiency_pct": 43.2, "output_kw_max": 23.0, "final_year_of_manufacture": null, "raw": ["000751", "000206", "0", "2010/Sep/13 17:03", "Saunier Duval", "Saunier Duval", "Thelia", "23E", "", "", "obsolete", "1", "0", "0", "2", "0", "", "", "1", "2", "2", "23", "23", "", "", "71.0", "62.0", "", "43.2", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 752, "brand_name": "Saunier Duval", "model_name": "Thelia", "model_qualifier": "30", "winter_efficiency_pct": 71.0, "summer_efficiency_pct": 62.0, "comparative_hot_water_efficiency_pct": 43.2, "output_kw_max": 30.0, "final_year_of_manufacture": null, "raw": ["000752", "000206", "0", "2010/Sep/13 17:03", "Saunier Duval", "Saunier Duval", "Thelia", "30", "", "", "obsolete", "1", "0", "0", "2", "0", "", "", "1", "2", "2", "30", "30", "", "", "71.0", "62.0", "", "43.2", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 753, "brand_name": "Saunier Duval", "model_name": "Themis", "model_qualifier": "23", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 57.0, "comparative_hot_water_efficiency_pct": 39.7, "output_kw_max": 23.0, "final_year_of_manufacture": null, "raw": ["000753", "000206", "0", "2010/Sep/13 17:03", "Saunier Duval", "Saunier Duval", "Themis", "23", "", "", "obsolete", "1", "0", "0", "2", "0", "", "", "1", "1", "1", "23", "23", "", "", "66.0", "57.0", "", "39.7", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 754, "brand_name": "Saunier Duval", "model_name": "Sd", "model_qualifier": "235C", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 57.0, "comparative_hot_water_efficiency_pct": 39.7, "output_kw_max": 34.8, "final_year_of_manufacture": null, "raw": ["000754", "000206", "0", "2010/Sep/13 17:03", "Saunier Duval", "Saunier Duval", "Sd", "235C", "", "", "obsolete", "1", "0", "0", "2", "0", "", "", "1", "1", "1", "34.8", "34.8", "", "", "66.0", "57.0", "", "39.7", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 755, "brand_name": "Saunier Duval", "model_name": "Thelia", "model_qualifier": "SB23", "winter_efficiency_pct": 71.0, "summer_efficiency_pct": 62.0, "comparative_hot_water_efficiency_pct": 43.2, "output_kw_max": null, "final_year_of_manufacture": null, "raw": ["000755", "000206", "0", "2010/Sep/13 17:03", "Saunier Duval", "Saunier Duval", "Thelia", "SB23", "", "", "obsolete", "1", "0", "0", "2", "0", "", "", "1", "2", "2", "", "", "", "", "71.0", "62.0", "", "43.2", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 757, "brand_name": "Saunier Duval", "model_name": "Thelia", "model_qualifier": "Twin 28e", "winter_efficiency_pct": 71.0, "summer_efficiency_pct": 62.0, "comparative_hot_water_efficiency_pct": 43.2, "output_kw_max": null, "final_year_of_manufacture": null, "raw": ["000757", "000206", "0", "2010/Sep/13 17:03", "Saunier Duval", "Saunier Duval", "Thelia", "Twin 28e", "", "", "obsolete", "1", "0", "0", "2", "0", "", "", "1", "2", "2", "", "", "", "", "71.0", "62.0", "", "43.2", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 761, "brand_name": "Sime Heating Products (UK)", "model_name": "Super 102 Deluxe", "model_qualifier": "11006", "winter_efficiency_pct": 71.0, "summer_efficiency_pct": 62.0, "comparative_hot_water_efficiency_pct": 43.2, "output_kw_max": 29.7, "final_year_of_manufacture": 1999, "raw": ["000761", "000213", "0", "2010/Sep/13 17:03", "Sime Heating Products (UK)", "Sime Heating Products (UK)", "Super 102 Deluxe", "11006", "", "1996", "1999", "1", "2", "0", "2", "0", "", "", "1", "2", "2", "15.3", "29.7", "", "", "71.0", "62.0", "", "43.2", "", "3", "", "", "0", "0", "0", "210", "2", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 763, "brand_name": "Sime Heating Products (UK)", "model_name": "Friendly", "model_qualifier": "11010", "winter_efficiency_pct": 71.0, "summer_efficiency_pct": 62.0, "comparative_hot_water_efficiency_pct": 43.2, "output_kw_max": 23.4, "final_year_of_manufacture": 1999, "raw": ["000763", "000213", "0", "2010/Sep/13 17:03", "Sime Heating Products (UK)", "Sime Heating Products (UK)", "Friendly", "11010", "", "1996", "1999", "1", "2", "0", "2", "0", "", "", "1", "2", "2", "9.7", "23.4", "", "", "71.0", "62.0", "", "43.2", "", "3", "", "", "0", "2", "0", "150", "50", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 764, "brand_name": "Sime Heating Products (UK)", "model_name": "Friendly", "model_qualifier": "E", "winter_efficiency_pct": 71.0, "summer_efficiency_pct": 62.0, "comparative_hot_water_efficiency_pct": 43.2, "output_kw_max": 23.4, "final_year_of_manufacture": 1999, "raw": ["000764", "000213", "0", "2010/Sep/13 17:03", "Sime Heating Products (UK)", "Sime Heating Products (UK)", "Friendly", "E", "", "1997", "1999", "1", "2", "0", "2", "0", "", "", "1", "2", "2", "9.7", "23.4", "", "", "71.0", "62.0", "", "43.2", "", "3", "", "", "0", "0", "0", "150", "2", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 766, "brand_name": "Vaillant", "model_name": "Combicompact", "model_qualifier": "vcw221h", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 57.0, "comparative_hot_water_efficiency_pct": 39.7, "output_kw_max": 22.0, "final_year_of_manufacture": 1996, "raw": ["000766", "000031", "0", "2011/Jul/14 11:33", "Vaillant", "Vaillant", "Combicompact", "vcw221h", "4704414", "", "1996", "1", "0", "0", "2", "0", "", "", "1", "2", "1", "22", "22", "", "", "66.0", "57.0", "", "39.7", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 767, "brand_name": "Vaillant", "model_name": "Combicompact", "model_qualifier": "vcw240h", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 57.0, "comparative_hot_water_efficiency_pct": 39.7, "output_kw_max": 24.0, "final_year_of_manufacture": 1996, "raw": ["000767", "000031", "0", "2010/Sep/13 17:03", "Vaillant", "Vaillant", "Combicompact", "vcw240h", "4704415", "", "1996", "1", "0", "0", "2", "0", "", "", "1", "1", "1", "24", "24", "", "", "66.0", "57.0", "", "39.7", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 768, "brand_name": "Vaillant", "model_name": "Combicompact", "model_qualifier": "vcw242eh", "winter_efficiency_pct": 71.0, "summer_efficiency_pct": 62.0, "comparative_hot_water_efficiency_pct": 43.2, "output_kw_max": 24.0, "final_year_of_manufacture": 1995, "raw": ["000768", "000031", "0", "2010/Sep/13 17:03", "Vaillant", "Vaillant", "Combicompact", "vcw242eh", "4704413", "", "1995", "1", "0", "0", "2", "0", "", "", "1", "2", "2", "24", "24", "", "", "71.0", "62.0", "", "43.2", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 769, "brand_name": "Vaillant", "model_name": "Combicompact", "model_qualifier": "vcw280h", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 57.0, "comparative_hot_water_efficiency_pct": 39.7, "output_kw_max": 27.6, "final_year_of_manufacture": 1996, "raw": ["000769", "000031", "0", "2010/Sep/13 17:03", "Vaillant", "Vaillant", "Combicompact", "vcw280h", "4704416", "", "1996", "1", "0", "0", "2", "0", "", "", "1", "1", "1", "27.6", "27.6", "", "", "66.0", "57.0", "", "39.7", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 770, "brand_name": "Vaillant", "model_name": "Combicompact", "model_qualifier": "vcw282eh", "winter_efficiency_pct": 71.0, "summer_efficiency_pct": 62.0, "comparative_hot_water_efficiency_pct": 43.2, "output_kw_max": 28.0, "final_year_of_manufacture": 1995, "raw": ["000770", "000031", "0", "2010/Sep/13 17:03", "Vaillant", "Vaillant", "Combicompact", "vcw282eh", "4704418", "", "1995", "1", "0", "0", "2", "0", "", "", "1", "2", "2", "28", "28", "", "", "71.0", "62.0", "", "43.2", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 771, "brand_name": "Vaillant", "model_name": "T3Wcombi", "model_qualifier": "vcw20/1t3w", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 57.0, "comparative_hot_water_efficiency_pct": 39.7, "output_kw_max": 24.0, "final_year_of_manufacture": 1988, "raw": ["000771", "000031", "0", "2010/Sep/13 17:03", "Vaillant", "Vaillant", "T3Wcombi", "vcw20/1t3w", "4704403", "", "1988", "1", "0", "0", "2", "0", "", "", "1", "1", "1", "24", "24", "", "", "66.0", "57.0", "", "39.7", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 772, "brand_name": "Vaillant", "model_name": "T3Wcombi", "model_qualifier": "vcw25/1t3w", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 57.0, "comparative_hot_water_efficiency_pct": 39.7, "output_kw_max": 26.6, "final_year_of_manufacture": 1988, "raw": ["000772", "000031", "0", "2010/Sep/13 17:03", "Vaillant", "Vaillant", "T3Wcombi", "vcw25/1t3w", "4704405", "", "1988", "1", "0", "0", "2", "0", "", "", "1", "1", "1", "26.6", "26.6", "", "", "66.0", "57.0", "", "39.7", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 773, "brand_name": "Vaillant", "model_name": "T3Wcombi", "model_qualifier": "vcwsine18t3w", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 57.0, "comparative_hot_water_efficiency_pct": 39.7, "output_kw_max": 19.5, "final_year_of_manufacture": 1988, "raw": ["000773", "000031", "0", "2010/Sep/13 17:03", "Vaillant", "Vaillant", "T3Wcombi", "vcwsine18t3w", "4704401", "", "1988", "1", "0", "0", "2", "0", "", "", "1", "2", "1", "19.5", "19.5", "", "", "66.0", "57.0", "", "39.7", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 774, "brand_name": "Vaillant", "model_name": "Thermocompact", "model_qualifier": "vc110h", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 10.5, "final_year_of_manufacture": 1996, "raw": ["000774", "000031", "0", "2010/Sep/13 17:03", "Vaillant", "Vaillant", "Thermocompact", "vc110h", "4104401", "", "1996", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "10.5", "10.5", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 775, "brand_name": "Vaillant", "model_name": "Thermocompact", "model_qualifier": "vc180h", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 18.0, "final_year_of_manufacture": 1996, "raw": ["000775", "000031", "0", "2010/Sep/13 17:03", "Vaillant", "Vaillant", "Thermocompact", "vc180h", "4104403", "", "1996", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "18", "18", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 776, "brand_name": "Vaillant", "model_name": "Thermocompact", "model_qualifier": "vc182eh", "winter_efficiency_pct": 73.0, "summer_efficiency_pct": 63.0, "comparative_hot_water_efficiency_pct": 45.9, "output_kw_max": 18.0, "final_year_of_manufacture": 1996, "raw": ["000776", "000031", "0", "2015/Jul/21 14:15", "Vaillant", "Vaillant", "Thermocompact", "vc182eh", "4104404", "", "1996", "1", "0", "0", "1", "0", "", "", "1", "2", "2", "18", "18", "", "", "73.0", "63.0", "", "45.9", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 777, "brand_name": "Vaillant", "model_name": "Thermocompact", "model_qualifier": "vc221h", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 22.0, "final_year_of_manufacture": 1996, "raw": ["000777", "000031", "0", "2010/Sep/13 17:03", "Vaillant", "Vaillant", "Thermocompact", "vc221h", "4104405", "", "1996", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "22", "22", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 778, "brand_name": "Vaillant", "model_name": "Thermocompact", "model_qualifier": "vc240h", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 24.0, "final_year_of_manufacture": 1996, "raw": ["000778", "000031", "0", "2010/Sep/13 17:03", "Vaillant", "Vaillant", "Thermocompact", "vc240h", "4104406", "", "1996", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "24", "24", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 779, "brand_name": "Vaillant", "model_name": "Thermocompact", "model_qualifier": "vc242eh", "winter_efficiency_pct": 73.0, "summer_efficiency_pct": 63.0, "comparative_hot_water_efficiency_pct": 45.9, "output_kw_max": 24.0, "final_year_of_manufacture": 1996, "raw": ["000779", "000031", "0", "2015/Jul/21 14:15", "Vaillant", "Vaillant", "Thermocompact", "vc242eh", "4104407", "", "1996", "1", "0", "0", "1", "0", "", "", "1", "2", "2", "24", "24", "", "", "73.0", "63.0", "", "45.9", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 780, "brand_name": "Vaillant", "model_name": "Thermocompact", "model_qualifier": "vc282eh", "winter_efficiency_pct": 73.0, "summer_efficiency_pct": 63.0, "comparative_hot_water_efficiency_pct": 45.9, "output_kw_max": 28.0, "final_year_of_manufacture": 1996, "raw": ["000780", "000031", "0", "2015/Jul/21 14:15", "Vaillant", "Vaillant", "Thermocompact", "vc282eh", "4104410", "", "1996", "1", "0", "0", "1", "0", "", "", "1", "2", "2", "28", "28", "", "", "73.0", "63.0", "", "45.9", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 781, "brand_name": "Vaillant", "model_name": "Vkboiler", "model_qualifier": "vk35", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 35.0, "final_year_of_manufacture": 1995, "raw": ["000781", "000031", "0", "2010/Sep/13 17:03", "Vaillant", "Vaillant", "Vkboiler", "vk35", "", "", "1995", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "35", "35", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 782, "brand_name": "Vaillant", "model_name": "Vkboiler", "model_qualifier": "vk41", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 41.0, "final_year_of_manufacture": 1995, "raw": ["000782", "000031", "0", "2010/Sep/13 17:03", "Vaillant", "Vaillant", "Vkboiler", "vk41", "", "", "1995", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "41", "41", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 783, "brand_name": "Vaillant", "model_name": "Vkboiler", "model_qualifier": "vk48", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 46.5, "final_year_of_manufacture": 1995, "raw": ["000783", "000031", "0", "2010/Sep/13 17:03", "Vaillant", "Vaillant", "Vkboiler", "vk48", "", "", "1995", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "46.5", "46.5", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 784, "brand_name": "Vaillant", "model_name": "Vkboiler", "model_qualifier": "vk58", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 58.1, "final_year_of_manufacture": 1995, "raw": ["000784", "000031", "0", "2010/Sep/13 17:03", "Vaillant", "Vaillant", "Vkboiler", "vk58", "", "", "1995", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "58.1", "58.1", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 798, "brand_name": "Worcester", "model_name": "Delglo", "model_qualifier": "2bf", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 12.3, "final_year_of_manufacture": 1991, "raw": ["000798", "000035", "0", "2010/Sep/13 17:03", "Worcester Heat Systems", "Worcester", "Delglo", "2bf", "4131122", "", "1991", "1", "1", "1", "1", "0", "", "", "1", "2", "1", "12.3", "12.3", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 799, "brand_name": "Worcester", "model_name": "Delglo", "model_qualifier": "2of", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 12.3, "final_year_of_manufacture": 1991, "raw": ["000799", "000035", "0", "2010/Sep/13 17:03", "Worcester Heat Systems", "Worcester", "Delglo", "2of", "4131121", "", "1991", "1", "1", "1", "1", "0", "", "", "1", "2", "1", "12.3", "12.3", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 800, "brand_name": "Worcester", "model_name": "Delglo", "model_qualifier": "3bf", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 12.3, "final_year_of_manufacture": 1991, "raw": ["000800", "000035", "0", "2010/Sep/13 17:03", "Worcester Heat Systems", "Worcester", "Delglo", "3bf", "4131126", "", "1991", "1", "1", "1", "1", "0", "", "", "1", "2", "1", "12.3", "12.3", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 801, "brand_name": "Worcester", "model_name": "Delglo", "model_qualifier": "3of", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 12.3, "final_year_of_manufacture": 1991, "raw": ["000801", "000035", "0", "2010/Sep/13 17:03", "Worcester Heat Systems", "Worcester", "Delglo", "3of", "4131125", "", "1991", "1", "1", "1", "1", "0", "", "", "1", "2", "1", "12.3", "12.3", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 802, "brand_name": "Worcester", "model_name": "Heatslave", "model_qualifier": "9.24bf", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 39.2, "output_kw_max": 8.8, "final_year_of_manufacture": 1989, "raw": ["000802", "000035", "0", "2010/Sep/13 17:03", "Worcester Heat Systems", "Worcester", "Heatslave", "9.24bf", "4731102", "", "1989", "1", "2", "1", "2", "0", "", "", "1", "2", "1", "8.8", "8.8", "", "", "66.0", "56.0", "", "39.2", "", "3", "", "", "0", "2", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 803, "brand_name": "Worcester", "model_name": "Heatslave", "model_qualifier": "9.24of", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 39.2, "output_kw_max": 24.0, "final_year_of_manufacture": 1989, "raw": ["000803", "000035", "0", "2010/Sep/13 17:03", "Worcester Heat Systems", "Worcester", "Heatslave", "9.24of", "4731101", "", "1989", "1", "2", "1", "2", "0", "", "", "1", "1", "1", "24", "24", "", "", "66.0", "56.0", "", "39.2", "", "3", "", "", "0", "2", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 804, "brand_name": "Worcester", "model_name": "Heatslave", "model_qualifier": "9.24rsf", "winter_efficiency_pct": 71.0, "summer_efficiency_pct": 61.0, "comparative_hot_water_efficiency_pct": 42.8, "output_kw_max": 24.0, "final_year_of_manufacture": 1989, "raw": ["000804", "000035", "0", "2010/Sep/13 17:03", "Worcester Heat Systems", "Worcester", "Heatslave", "9.24rsf", "4731103", "", "1989", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "24", "24", "", "", "71.0", "61.0", "", "42.8", "", "3", "", "", "0", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 805, "brand_name": "Worcester", "model_name": "Heatslave", "model_qualifier": "highflow3.5rsf", "winter_efficiency_pct": 73.0, "summer_efficiency_pct": 63.0, "comparative_hot_water_efficiency_pct": 45.9, "output_kw_max": 23.44, "final_year_of_manufacture": 1993, "raw": ["000805", "000035", "0", "2015/Jul/21 14:15", "Worcester Heat Systems", "Worcester", "Heatslave", "highflow3.5rsf", "4131140", "", "1993", "1", "1", "1", "1", "0", "", "", "1", "2", "2", "23.44", "23.44", "", "", "73.0", "63.0", "", "45.9", "", "3", "", "", "0", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 806, "brand_name": "Worcester", "model_name": "Heatslave", "model_qualifier": "highflow4.5bf", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 22.9, "final_year_of_manufacture": 1993, "raw": ["000806", "000035", "0", "2010/Sep/13 17:03", "Worcester Heat Systems", "Worcester", "Heatslave", "highflow4.5bf", "4131142", "", "1993", "1", "1", "1", "1", "0", "", "", "1", "2", "1", "22.9", "22.9", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 807, "brand_name": "Worcester", "model_name": "Heatslave", "model_qualifier": "highflow4.5of", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 22.9, "final_year_of_manufacture": 1993, "raw": ["000807", "000035", "0", "2010/Sep/13 17:03", "Worcester Heat Systems", "Worcester", "Heatslave", "highflow4.5of", "4131141", "", "1993", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "22.9", "22.9", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 808, "brand_name": "Worcester", "model_name": "Heatslave", "model_qualifier": "highflowbf", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 22.9, "final_year_of_manufacture": 1990, "raw": ["000808", "000035", "0", "2010/Sep/13 17:03", "Worcester Heat Systems", "Worcester", "Heatslave", "highflowbf", "4131139", "", "1990", "1", "1", "1", "1", "0", "", "", "1", "2", "1", "22.9", "22.9", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 809, "brand_name": "Worcester", "model_name": "Heatslave", "model_qualifier": "highflowof", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 22.9, "final_year_of_manufacture": 1990, "raw": ["000809", "000035", "0", "2010/Sep/13 17:03", "Worcester Heat Systems", "Worcester", "Heatslave", "highflowof", "4131138", "", "1990", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "22.9", "22.9", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 810, "brand_name": "Worcester", "model_name": "Heatslave", "model_qualifier": "juniorbf", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 12.3, "final_year_of_manufacture": 1987, "raw": ["000810", "000035", "0", "2010/Sep/13 17:03", "Worcester Heat Systems", "Worcester", "Heatslave", "juniorbf", "4131124", "", "1987", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "12.3", "12.3", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 811, "brand_name": "Worcester", "model_name": "Heatslave", "model_qualifier": "juniorof", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 12.3, "final_year_of_manufacture": 1987, "raw": ["000811", "000035", "0", "2010/Sep/13 17:03", "Worcester Heat Systems", "Worcester", "Heatslave", "juniorof", "4131123", "", "1987", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "12.3", "12.3", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 813, "brand_name": "Worcester", "model_name": "Heatslave", "model_qualifier": "senior12bf", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 12.3, "final_year_of_manufacture": 1989, "raw": ["000813", "000035", "0", "2010/Sep/13 17:03", "Worcester Heat Systems", "Worcester", "Heatslave", "senior12bf", "4131129", "", "1989", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "12.3", "12.3", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 815, "brand_name": "Worcester", "model_name": "Heatslave", "model_qualifier": "senior12of", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 12.3, "final_year_of_manufacture": 1989, "raw": ["000815", "000035", "0", "2010/Sep/13 17:03", "Worcester Heat Systems", "Worcester", "Heatslave", "senior12of", "4131128", "", "1989", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "12.3", "12.3", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 817, "brand_name": "Worcester", "model_name": "Heatslave", "model_qualifier": "senior15bf", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 14.66, "final_year_of_manufacture": 1988, "raw": ["000817", "000035", "0", "2010/Sep/13 17:03", "Worcester Heat Systems", "Worcester", "Heatslave", "senior15bf", "4131133", "", "1988", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "14.66", "14.66", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 819, "brand_name": "Worcester", "model_name": "Heatslave", "model_qualifier": "senior15of", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 14.66, "final_year_of_manufacture": 1988, "raw": ["000819", "000035", "0", "2010/Sep/13 17:03", "Worcester Heat Systems", "Worcester", "Heatslave", "senior15of", "4131132", "", "1988", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "14.66", "14.66", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 820, "brand_name": "Worcester", "model_name": "Heatslave", "model_qualifier": "senior6bf", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 12.3, "final_year_of_manufacture": 1991, "raw": ["000820", "000035", "0", "2010/Sep/13 17:03", "Worcester Heat Systems", "Worcester", "Heatslave", "senior6bf", "4131136", "", "1991", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "12.3", "12.3", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 821, "brand_name": "Worcester", "model_name": "Heatslave", "model_qualifier": "senior6of", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 12.3, "final_year_of_manufacture": 1991, "raw": ["000821", "000035", "0", "2010/Sep/13 17:03", "Worcester Heat Systems", "Worcester", "Heatslave", "senior6of", "4131135", "", "1991", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "12.3", "12.3", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 822, "brand_name": "Worcester", "model_name": "Heatslave 2", "model_qualifier": "g40bf", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 11.72, "final_year_of_manufacture": 1984, "raw": ["000822", "000035", "0", "2010/Sep/13 17:03", "Worcester Heat Systems", "Worcester", "Heatslave 2", "g40bf", "4131113", "", "1984", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "11.72", "11.72", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 824, "brand_name": "Worcester", "model_name": "Heatslave 2", "model_qualifier": "g40of", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 11.72, "final_year_of_manufacture": 1984, "raw": ["000824", "000035", "0", "2010/Sep/13 17:03", "Worcester Heat Systems", "Worcester", "Heatslave 2", "g40of", "4131114", "", "1984", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "11.72", "11.72", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 826, "brand_name": "Worcester", "model_name": "Heatslave 2", "model_qualifier": "g50bf", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 14.66, "final_year_of_manufacture": 1984, "raw": ["000826", "000035", "0", "2010/Sep/13 17:03", "Worcester Heat Systems", "Worcester", "Heatslave 2", "g50bf", "4131117", "", "1984", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "14.66", "14.66", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 828, "brand_name": "Worcester", "model_name": "Heatslave 2", "model_qualifier": "g50of", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 14.66, "final_year_of_manufacture": 1984, "raw": ["000828", "000035", "0", "2010/Sep/13 17:03", "Worcester Heat Systems", "Worcester", "Heatslave 2", "g50of", "4131120", "", "1984", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "14.66", "14.66", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 830, "brand_name": "Worcester", "model_name": "240bf", "model_qualifier": "", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 39.2, "output_kw_max": 24.0, "final_year_of_manufacture": 1997, "raw": ["000830", "000035", "0", "2010/Sep/13 17:03", "Worcester Heat Systems", "Worcester", "240bf", "", "4731110", "", "1997", "1", "2", "1", "2", "0", "", "", "1", "2", "1", "24", "24", "", "", "66.0", "56.0", "", "39.2", "", "3", "", "", "0", "2", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 831, "brand_name": "Worcester", "model_name": "240of", "model_qualifier": "", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 39.2, "output_kw_max": 24.0, "final_year_of_manufacture": 1997, "raw": ["000831", "000035", "0", "2010/Sep/13 17:03", "Worcester Heat Systems", "Worcester", "240of", "", "4731109", "", "1997", "1", "2", "1", "2", "0", "", "", "1", "1", "1", "24", "24", "", "", "66.0", "56.0", "", "39.2", "", "3", "", "", "0", "2", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 832, "brand_name": "Worcester", "model_name": "240rsf", "model_qualifier": "", "winter_efficiency_pct": 71.0, "summer_efficiency_pct": 61.0, "comparative_hot_water_efficiency_pct": 42.8, "output_kw_max": 16.1, "final_year_of_manufacture": 1997, "raw": ["000832", "000035", "0", "2010/Sep/13 17:03", "Worcester Heat Systems", "Worcester", "240rsf", "", "4731112", "", "1997", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "16.1", "16.1", "", "", "71.0", "61.0", "", "42.8", "", "3", "", "", "0", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 833, "brand_name": "Worcester", "model_name": "280rsf", "model_qualifier": "", "winter_efficiency_pct": 71.0, "summer_efficiency_pct": 61.0, "comparative_hot_water_efficiency_pct": 42.8, "output_kw_max": 24.0, "final_year_of_manufacture": 1997, "raw": ["000833", "000035", "0", "2010/Sep/13 17:03", "Worcester Heat Systems", "Worcester", "280rsf", "", "4731111", "", "1997", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "24", "24", "", "", "71.0", "61.0", "", "42.8", "", "3", "", "", "0", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 837, "brand_name": "Worcester", "model_name": "9.24electronicrsf", "model_qualifier": "", "winter_efficiency_pct": 71.0, "summer_efficiency_pct": 61.0, "comparative_hot_water_efficiency_pct": 42.8, "output_kw_max": 24.0, "final_year_of_manufacture": 1992, "raw": ["000837", "000035", "0", "2010/Sep/13 17:03", "Worcester Heat Systems", "Worcester", "9.24electronicrsf", "", "4731106", "", "1992", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "24", "24", "", "", "71.0", "61.0", "", "42.8", "", "3", "", "", "0", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 838, "brand_name": "Worcester", "model_name": "9.24electronicrsfe", "model_qualifier": "", "winter_efficiency_pct": 71.0, "summer_efficiency_pct": 61.0, "comparative_hot_water_efficiency_pct": 42.8, "output_kw_max": 24.0, "final_year_of_manufacture": 1992, "raw": ["000838", "000035", "0", "2010/Sep/13 17:03", "Worcester Heat Systems", "Worcester", "9.24electronicrsfe", "", "4731107", "", "1992", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "24", "24", "", "", "71.0", "61.0", "", "42.8", "", "3", "", "", "0", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 843, "brand_name": "Worcester", "model_name": "240", "model_qualifier": "CF", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 39.2, "output_kw_max": 24.0, "final_year_of_manufacture": 1997, "raw": ["000843", "000035", "0", "2010/Sep/13 17:03", "Worcester Heat Systems", "Worcester", "240", "CF", "47 311 09", "", "1997", "1", "2", "1", "2", "0", "", "", "1", "1", "1", "24", "24", "", "", "66.0", "56.0", "", "39.2", "", "3", "", "", "0", "0", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 847, "brand_name": "Worcester", "model_name": "Firefly HD II", "model_qualifier": "50", "winter_efficiency_pct": 65.0, "summer_efficiency_pct": 53.0, "comparative_hot_water_efficiency_pct": 38.9, "output_kw_max": 14.7, "final_year_of_manufacture": 1985, "raw": ["000847", "000035", "0", "2010/Sep/13 17:03", "Worcester Heat Systems", "Worcester", "Firefly HD II", "50", "", "", "1985", "4", "1", "1", "1", "0", "", "", "1", "1", "1", "14.7", "14.7", "", "", "65.0", "53.0", "", "38.9", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 848, "brand_name": "Worcester", "model_name": "Firefly HD II", "model_qualifier": "50 D type", "winter_efficiency_pct": 65.0, "summer_efficiency_pct": 53.0, "comparative_hot_water_efficiency_pct": 38.9, "output_kw_max": 14.6, "final_year_of_manufacture": 1985, "raw": ["000848", "000035", "0", "2010/Sep/13 17:03", "Worcester Heat Systems", "Worcester", "Firefly HD II", "50 D type", "", "", "1985", "4", "1", "1", "1", "0", "", "", "1", "1", "1", "14.6", "14.6", "", "", "65.0", "53.0", "", "38.9", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 850, "brand_name": "Worcester", "model_name": "Firefly HD II", "model_qualifier": "60 D type", "winter_efficiency_pct": 65.0, "summer_efficiency_pct": 53.0, "comparative_hot_water_efficiency_pct": 38.9, "output_kw_max": 17.6, "final_year_of_manufacture": 1985, "raw": ["000850", "000035", "0", "2010/Sep/13 17:03", "Worcester Heat Systems", "Worcester", "Firefly HD II", "60 D type", "", "", "1985", "4", "1", "1", "1", "0", "", "", "1", "1", "1", "17.6", "17.6", "", "", "65.0", "53.0", "", "38.9", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 851, "brand_name": "Worcester", "model_name": "Firefly HD II", "model_qualifier": "70", "winter_efficiency_pct": 65.0, "summer_efficiency_pct": 53.0, "comparative_hot_water_efficiency_pct": 38.9, "output_kw_max": 20.5, "final_year_of_manufacture": 1985, "raw": ["000851", "000035", "0", "2010/Sep/13 17:03", "Worcester Heat Systems", "Worcester", "Firefly HD II", "70", "", "", "1985", "4", "1", "1", "1", "0", "", "", "1", "1", "1", "20.5", "20.5", "", "", "65.0", "53.0", "", "38.9", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 852, "brand_name": "Worcester", "model_name": "Firefly HD II", "model_qualifier": "80", "winter_efficiency_pct": 65.0, "summer_efficiency_pct": 53.0, "comparative_hot_water_efficiency_pct": 38.9, "output_kw_max": 23.4, "final_year_of_manufacture": 1985, "raw": ["000852", "000035", "0", "2010/Sep/13 17:03", "Worcester Heat Systems", "Worcester", "Firefly HD II", "80", "", "", "1985", "4", "1", "1", "1", "0", "", "", "1", "1", "1", "23.4", "23.4", "", "", "65.0", "53.0", "", "38.9", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 853, "brand_name": "Worcester", "model_name": "Firefly HD II", "model_qualifier": "100", "winter_efficiency_pct": 65.0, "summer_efficiency_pct": 53.0, "comparative_hot_water_efficiency_pct": 38.9, "output_kw_max": 29.3, "final_year_of_manufacture": 1985, "raw": ["000853", "000035", "0", "2010/Sep/13 17:03", "Worcester Heat Systems", "Worcester", "Firefly HD II", "100", "", "", "1985", "4", "1", "1", "1", "0", "", "", "1", "1", "1", "29.3", "29.3", "", "", "65.0", "53.0", "", "38.9", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 855, "brand_name": "Worcester", "model_name": "Firefly", "model_qualifier": "PJ90-120", "winter_efficiency_pct": 65.0, "summer_efficiency_pct": 53.0, "comparative_hot_water_efficiency_pct": 38.9, "output_kw_max": 35.2, "final_year_of_manufacture": 1985, "raw": ["000855", "000035", "0", "2010/Sep/13 17:03", "Worcester Heat Systems", "Worcester", "Firefly", "PJ90-120", "", "", "1985", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "26.4", "35.2", "", "", "65.0", "53.0", "", "38.9", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 856, "brand_name": "Worcester", "model_name": "Firefly HD II", "model_qualifier": "40", "winter_efficiency_pct": 65.0, "summer_efficiency_pct": 53.0, "comparative_hot_water_efficiency_pct": 38.9, "output_kw_max": 12.3, "final_year_of_manufacture": 1985, "raw": ["000856", "000035", "0", "2010/Sep/13 17:03", "Worcester Heat Systems", "Worcester", "Firefly HD II", "40", "", "", "1985", "4", "1", "1", "1", "0", "", "", "1", "1", "1", "12.3", "12.3", "", "", "65.0", "53.0", "", "38.9", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 857, "brand_name": "Worcester", "model_name": "Firefly HD II", "model_qualifier": "40 D type", "winter_efficiency_pct": 65.0, "summer_efficiency_pct": 53.0, "comparative_hot_water_efficiency_pct": 38.9, "output_kw_max": 11.7, "final_year_of_manufacture": 1985, "raw": ["000857", "000035", "0", "2010/Sep/13 17:03", "Worcester Heat Systems", "Worcester", "Firefly HD II", "40 D type", "", "", "1985", "4", "1", "1", "1", "0", "", "", "1", "1", "1", "11.7", "11.7", "", "", "65.0", "53.0", "", "38.9", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 858, "brand_name": "Worcester", "model_name": "Heatslave", "model_qualifier": "12/14RS", "winter_efficiency_pct": 71.0, "summer_efficiency_pct": 62.0, "comparative_hot_water_efficiency_pct": 43.2, "output_kw_max": 14.0, "final_year_of_manufacture": 1996, "raw": ["000858", "000035", "0", "2010/Sep/13 17:03", "Worcester Heat Systems", "Worcester", "Heatslave", "12/14RS", "HHSC14OSO.AIR", "", "1996", "4", "1", "1", "2", "0", "", "", "1", "2", "2", "12", "14", "", "", "71.0", "62.0", "", "43.2", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 860, "brand_name": "Worcester", "model_name": "Heatslave", "model_qualifier": "20/25RS", "winter_efficiency_pct": 71.0, "summer_efficiency_pct": 62.0, "comparative_hot_water_efficiency_pct": 43.2, "output_kw_max": 25.0, "final_year_of_manufacture": 1996, "raw": ["000860", "000035", "0", "2010/Sep/13 17:03", "Worcester Heat Systems", "Worcester", "Heatslave", "20/25RS", "HHSC25OSO.AIV", "", "1996", "4", "1", "1", "2", "0", "", "", "1", "2", "2", "20", "25", "", "", "71.0", "62.0", "", "43.2", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 890, "brand_name": "Aquaflame", "model_name": "Gem", "model_qualifier": "50 B", "winter_efficiency_pct": 70.0, "summer_efficiency_pct": 58.0, "comparative_hot_water_efficiency_pct": 42.6, "output_kw_max": 14.7, "final_year_of_manufacture": 1997, "raw": ["000890", "000039", "0", "2010/Sep/13 17:03", "Aquaflame", "Aquaflame", "Gem", "50 B", "", "", "1997", "4", "0", "0", "1", "0", "", "", "1", "2", "1", "14.7", "14.7", "", "", "70.0", "58.0", "", "42.6", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 891, "brand_name": "Aquaflame", "model_name": "Gem", "model_qualifier": "50 F", "winter_efficiency_pct": 70.0, "summer_efficiency_pct": 58.0, "comparative_hot_water_efficiency_pct": 42.6, "output_kw_max": 14.7, "final_year_of_manufacture": 1997, "raw": ["000891", "000039", "0", "2010/Sep/13 17:03", "Aquaflame", "Aquaflame", "Gem", "50 F", "", "", "1997", "4", "0", "0", "1", "0", "", "", "1", "2", "2", "14.7", "14.7", "", "", "70.0", "58.0", "", "42.6", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 892, "brand_name": "Aquaflame", "model_name": "Gem", "model_qualifier": "70 B", "winter_efficiency_pct": 70.0, "summer_efficiency_pct": 58.0, "comparative_hot_water_efficiency_pct": 42.6, "output_kw_max": 20.5, "final_year_of_manufacture": 1997, "raw": ["000892", "000039", "0", "2010/Sep/13 17:03", "Aquaflame", "Aquaflame", "Gem", "70 B", "", "", "1997", "4", "0", "0", "1", "0", "", "", "1", "2", "1", "20.5", "20.5", "", "", "70.0", "58.0", "", "42.6", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 893, "brand_name": "Aquaflame", "model_name": "Gem", "model_qualifier": "70 F", "winter_efficiency_pct": 70.0, "summer_efficiency_pct": 58.0, "comparative_hot_water_efficiency_pct": 42.6, "output_kw_max": 20.5, "final_year_of_manufacture": 1997, "raw": ["000893", "000039", "0", "2010/Sep/13 17:03", "Aquaflame", "Aquaflame", "Gem", "70 F", "", "", "1997", "4", "0", "0", "1", "0", "", "", "1", "2", "2", "20.5", "20.5", "", "", "70.0", "58.0", "", "42.6", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 894, "brand_name": "Aquaflame", "model_name": "Gem", "model_qualifier": "90 B", "winter_efficiency_pct": 70.0, "summer_efficiency_pct": 58.0, "comparative_hot_water_efficiency_pct": 42.6, "output_kw_max": 26.4, "final_year_of_manufacture": 1997, "raw": ["000894", "000039", "0", "2010/Sep/13 17:03", "Aquaflame", "Aquaflame", "Gem", "90 B", "", "", "1997", "4", "0", "0", "1", "0", "", "", "1", "2", "1", "26.4", "26.4", "", "", "70.0", "58.0", "", "42.6", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 895, "brand_name": "Aquaflame", "model_name": "Gem", "model_qualifier": "90 F", "winter_efficiency_pct": 70.0, "summer_efficiency_pct": 58.0, "comparative_hot_water_efficiency_pct": 42.6, "output_kw_max": 26.4, "final_year_of_manufacture": 1997, "raw": ["000895", "000039", "0", "2010/Sep/13 17:03", "Aquaflame", "Aquaflame", "Gem", "90 F", "", "", "1997", "4", "0", "0", "1", "0", "", "", "1", "2", "2", "26.4", "26.4", "", "", "70.0", "58.0", "", "42.6", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 896, "brand_name": "Aquaflame", "model_name": "Quartz", "model_qualifier": "110 B", "winter_efficiency_pct": 70.0, "summer_efficiency_pct": 58.0, "comparative_hot_water_efficiency_pct": 42.6, "output_kw_max": 32.2, "final_year_of_manufacture": 1997, "raw": ["000896", "000039", "0", "2010/Sep/13 17:03", "Aquaflame", "Aquaflame", "Quartz", "110 B", "", "", "1997", "4", "0", "0", "1", "0", "", "", "1", "2", "1", "32.2", "32.2", "", "", "70.0", "58.0", "", "42.6", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 897, "brand_name": "Aquaflame", "model_name": "Quartz", "model_qualifier": "110 F", "winter_efficiency_pct": 70.0, "summer_efficiency_pct": 58.0, "comparative_hot_water_efficiency_pct": 42.6, "output_kw_max": 32.2, "final_year_of_manufacture": 1997, "raw": ["000897", "000039", "0", "2010/Sep/13 17:03", "Aquaflame", "Aquaflame", "Quartz", "110 F", "", "", "1997", "4", "0", "0", "1", "0", "", "", "1", "2", "2", "32.2", "32.2", "", "", "70.0", "58.0", "", "42.6", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 898, "brand_name": "Aquaflame", "model_name": "Quartz", "model_qualifier": "135 B", "winter_efficiency_pct": 70.0, "summer_efficiency_pct": 58.0, "comparative_hot_water_efficiency_pct": 42.6, "output_kw_max": 39.6, "final_year_of_manufacture": 1997, "raw": ["000898", "000039", "0", "2010/Sep/13 17:03", "Aquaflame", "Aquaflame", "Quartz", "135 B", "", "", "1997", "4", "0", "0", "1", "0", "", "", "1", "2", "1", "39.6", "39.6", "", "", "70.0", "58.0", "", "42.6", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 899, "brand_name": "Aquaflame", "model_name": "Quartz", "model_qualifier": "135 F", "winter_efficiency_pct": 70.0, "summer_efficiency_pct": 58.0, "comparative_hot_water_efficiency_pct": 42.6, "output_kw_max": 39.6, "final_year_of_manufacture": 1997, "raw": ["000899", "000039", "0", "2010/Sep/13 17:03", "Aquaflame", "Aquaflame", "Quartz", "135 F", "", "", "1997", "4", "0", "0", "1", "0", "", "", "1", "2", "2", "39.6", "39.6", "", "", "70.0", "58.0", "", "42.6", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 900, "brand_name": "Aquaflame", "model_name": "Quartz", "model_qualifier": "160 B", "winter_efficiency_pct": 70.0, "summer_efficiency_pct": 58.0, "comparative_hot_water_efficiency_pct": 42.6, "output_kw_max": 46.9, "final_year_of_manufacture": 1997, "raw": ["000900", "000039", "0", "2010/Sep/13 17:03", "Aquaflame", "Aquaflame", "Quartz", "160 B", "", "", "1997", "4", "0", "0", "1", "0", "", "", "1", "2", "1", "46.9", "46.9", "", "", "70.0", "58.0", "", "42.6", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 901, "brand_name": "Aquaflame", "model_name": "Quartz", "model_qualifier": "160 F", "winter_efficiency_pct": 70.0, "summer_efficiency_pct": 58.0, "comparative_hot_water_efficiency_pct": 42.6, "output_kw_max": 46.9, "final_year_of_manufacture": 1997, "raw": ["000901", "000039", "0", "2010/Sep/13 17:03", "Aquaflame", "Aquaflame", "Quartz", "160 F", "", "", "1997", "4", "0", "0", "1", "0", "", "", "1", "2", "2", "46.9", "46.9", "", "", "70.0", "58.0", "", "42.6", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 902, "brand_name": "Aquaflame", "model_name": "Gem", "model_qualifier": "50", "winter_efficiency_pct": 70.0, "summer_efficiency_pct": 58.0, "comparative_hot_water_efficiency_pct": 42.6, "output_kw_max": null, "final_year_of_manufacture": 1997, "raw": ["000902", "000039", "0", "2010/Sep/13 17:03", "Aquaflame", "Aquaflame", "Gem", "50", "", "", "1997", "4", "0", "0", "1", "0", "", "", "1", "2", "2", "", "", "", "", "70.0", "58.0", "", "42.6", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 903, "brand_name": "Aquaflame", "model_name": "Gem", "model_qualifier": "70", "winter_efficiency_pct": 70.0, "summer_efficiency_pct": 58.0, "comparative_hot_water_efficiency_pct": 42.6, "output_kw_max": null, "final_year_of_manufacture": 1997, "raw": ["000903", "000039", "0", "2010/Sep/13 17:03", "Aquaflame", "Aquaflame", "Gem", "70", "", "", "1997", "4", "0", "0", "1", "0", "", "", "1", "2", "2", "", "", "", "", "70.0", "58.0", "", "42.6", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 904, "brand_name": "Aquaflame", "model_name": "Gem", "model_qualifier": "90", "winter_efficiency_pct": 70.0, "summer_efficiency_pct": 58.0, "comparative_hot_water_efficiency_pct": 42.6, "output_kw_max": null, "final_year_of_manufacture": 1997, "raw": ["000904", "000039", "0", "2010/Sep/13 17:03", "Aquaflame", "Aquaflame", "Gem", "90", "", "", "1997", "4", "0", "0", "1", "0", "", "", "1", "2", "2", "", "", "", "", "70.0", "58.0", "", "42.6", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 905, "brand_name": "Aquaflame", "model_name": "Quartz", "model_qualifier": "110", "winter_efficiency_pct": 70.0, "summer_efficiency_pct": 58.0, "comparative_hot_water_efficiency_pct": 42.6, "output_kw_max": null, "final_year_of_manufacture": 1997, "raw": ["000905", "000039", "0", "2010/Sep/13 17:03", "Aquaflame", "Aquaflame", "Quartz", "110", "", "", "1997", "4", "0", "0", "1", "0", "", "", "1", "2", "2", "", "", "", "", "70.0", "58.0", "", "42.6", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 906, "brand_name": "Aquaflame", "model_name": "Quartz", "model_qualifier": "135", "winter_efficiency_pct": 70.0, "summer_efficiency_pct": 58.0, "comparative_hot_water_efficiency_pct": 42.6, "output_kw_max": null, "final_year_of_manufacture": 1997, "raw": ["000906", "000039", "0", "2010/Sep/13 17:03", "Aquaflame", "Aquaflame", "Quartz", "135", "", "", "1997", "4", "0", "0", "1", "0", "", "", "1", "2", "2", "", "", "", "", "70.0", "58.0", "", "42.6", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 907, "brand_name": "Aquaflame", "model_name": "Quartz", "model_qualifier": "150", "winter_efficiency_pct": 70.0, "summer_efficiency_pct": 58.0, "comparative_hot_water_efficiency_pct": 42.6, "output_kw_max": null, "final_year_of_manufacture": 1997, "raw": ["000907", "000039", "0", "2010/Sep/13 17:03", "Aquaflame", "Aquaflame", "Quartz", "150", "", "", "1997", "4", "0", "0", "1", "0", "", "", "1", "2", "2", "", "", "", "", "70.0", "58.0", "", "42.6", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 918, "brand_name": "Boulter", "model_name": "Camray Compact", "model_qualifier": "50/70 B", "winter_efficiency_pct": 70.0, "summer_efficiency_pct": 58.0, "comparative_hot_water_efficiency_pct": 42.6, "output_kw_max": 15.0, "final_year_of_manufacture": null, "raw": ["000918", "000041", "0", "2010/Sep/13 17:03", "Boulter Boilers", "Boulter", "Camray Compact", "50/70 B", "", "", "obsolete", "4", "0", "0", "1", "0", "", "", "1", "2", "1", "12", "15", "", "", "70.0", "58.0", "", "42.6", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 919, "brand_name": "Boulter", "model_name": "Camray Compact", "model_qualifier": "50/70 F", "winter_efficiency_pct": 70.0, "summer_efficiency_pct": 58.0, "comparative_hot_water_efficiency_pct": 42.6, "output_kw_max": 15.0, "final_year_of_manufacture": null, "raw": ["000919", "000041", "0", "2010/Sep/13 17:03", "Boulter Boilers", "Boulter", "Camray Compact", "50/70 F", "", "", "obsolete", "4", "0", "0", "1", "0", "", "", "1", "2", "2", "12", "15", "", "", "70.0", "58.0", "", "42.6", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 920, "brand_name": "Boulter", "model_name": "Camray", "model_qualifier": "15/21 Internal", "winter_efficiency_pct": 70.0, "summer_efficiency_pct": 58.0, "comparative_hot_water_efficiency_pct": 42.6, "output_kw_max": 21.0, "final_year_of_manufacture": null, "raw": ["000920", "000041", "0", "2010/Sep/13 17:03", "Boulter Boilers", "Boulter", "Camray", "15/21 Internal", "", "", "obsolete", "4", "0", "0", "1", "0", "", "", "1", "2", "2", "15", "21", "", "", "70.0", "58.0", "", "42.6", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 922, "brand_name": "Boulter", "model_name": "Camray", "model_qualifier": "15/21 External", "winter_efficiency_pct": 70.0, "summer_efficiency_pct": 58.0, "comparative_hot_water_efficiency_pct": 42.6, "output_kw_max": 21.0, "final_year_of_manufacture": null, "raw": ["000922", "000041", "0", "2010/Sep/13 17:03", "Boulter Boilers", "Boulter", "Camray", "15/21 External", "", "", "obsolete", "4", "0", "0", "1", "0", "", "", "1", "2", "2", "15", "21", "", "", "70.0", "58.0", "", "42.6", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 923, "brand_name": "Boulter", "model_name": "Camray 3", "model_qualifier": "40/50", "winter_efficiency_pct": 70.0, "summer_efficiency_pct": 58.0, "comparative_hot_water_efficiency_pct": 42.6, "output_kw_max": 15.0, "final_year_of_manufacture": null, "raw": ["000923", "000041", "0", "2010/Sep/13 17:03", "Boulter Boilers", "Boulter", "Camray 3", "40/50", "", "", "obsolete", "4", "0", "0", "1", "0", "", "", "1", "2", "2", "12", "15", "", "", "70.0", "58.0", "", "42.6", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 925, "brand_name": "Boulter", "model_name": "Camray 3", "model_qualifier": "50/70", "winter_efficiency_pct": 70.0, "summer_efficiency_pct": 58.0, "comparative_hot_water_efficiency_pct": 42.6, "output_kw_max": 20.0, "final_year_of_manufacture": null, "raw": ["000925", "000041", "0", "2010/Sep/13 17:03", "Boulter Boilers", "Boulter", "Camray 3", "50/70", "", "", "obsolete", "4", "0", "0", "1", "0", "", "", "1", "2", "2", "14.5", "20", "", "", "70.0", "58.0", "", "42.6", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 929, "brand_name": "Boulter", "model_name": "Camray 3", "model_qualifier": "90/130 F", "winter_efficiency_pct": 70.0, "summer_efficiency_pct": 58.0, "comparative_hot_water_efficiency_pct": 42.6, "output_kw_max": 38.0, "final_year_of_manufacture": null, "raw": ["000929", "000041", "0", "2010/Sep/13 17:03", "Boulter Boilers", "Boulter", "Camray 3", "90/130 F", "", "", "obsolete", "4", "0", "0", "1", "0", "", "", "1", "2", "2", "26", "38", "", "", "70.0", "58.0", "", "42.6", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 930, "brand_name": "Boulter", "model_name": "Camray 3", "model_qualifier": "90/130 B", "winter_efficiency_pct": 70.0, "summer_efficiency_pct": 58.0, "comparative_hot_water_efficiency_pct": 42.6, "output_kw_max": 38.0, "final_year_of_manufacture": null, "raw": ["000930", "000041", "0", "2010/Sep/13 17:03", "Boulter Boilers", "Boulter", "Camray 3", "90/130 B", "", "", "obsolete", "4", "0", "0", "1", "0", "", "", "1", "2", "1", "26", "38", "", "", "70.0", "58.0", "", "42.6", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 931, "brand_name": "Boulter", "model_name": "Camray 3", "model_qualifier": "135/175 F", "winter_efficiency_pct": 70.0, "summer_efficiency_pct": 58.0, "comparative_hot_water_efficiency_pct": 42.6, "output_kw_max": 51.0, "final_year_of_manufacture": null, "raw": ["000931", "000041", "0", "2010/Sep/13 17:03", "Boulter Boilers", "Boulter", "Camray 3", "135/175 F", "", "", "obsolete", "4", "0", "0", "1", "0", "", "", "1", "2", "2", "40", "51", "", "", "70.0", "58.0", "", "42.6", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 932, "brand_name": "Boulter", "model_name": "Camray 3", "model_qualifier": "135/175 B", "winter_efficiency_pct": 70.0, "summer_efficiency_pct": 58.0, "comparative_hot_water_efficiency_pct": 42.6, "output_kw_max": 51.0, "final_year_of_manufacture": null, "raw": ["000932", "000041", "0", "2010/Sep/13 17:03", "Boulter Boilers", "Boulter", "Camray 3", "135/175 B", "", "", "obsolete", "4", "0", "0", "1", "0", "", "", "1", "2", "1", "40", "51", "", "", "70.0", "58.0", "", "42.6", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 933, "brand_name": "Boulter", "model_name": "Camray Combi", "model_qualifier": "90/130 F", "winter_efficiency_pct": 71.0, "summer_efficiency_pct": 62.0, "comparative_hot_water_efficiency_pct": 43.2, "output_kw_max": 38.0, "final_year_of_manufacture": null, "raw": ["000933", "000041", "0", "2010/Sep/13 17:03", "Boulter Boilers", "Boulter", "Camray Combi", "90/130 F", "", "", "obsolete", "4", "0", "0", "2", "0", "", "", "1", "2", "2", "26", "38", "", "", "71.0", "62.0", "", "43.2", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 934, "brand_name": "Boulter", "model_name": "Camray Combi", "model_qualifier": "90/130 B", "winter_efficiency_pct": 71.0, "summer_efficiency_pct": 62.0, "comparative_hot_water_efficiency_pct": 43.2, "output_kw_max": 38.0, "final_year_of_manufacture": null, "raw": ["000934", "000041", "0", "2010/Sep/13 17:03", "Boulter Boilers", "Boulter", "Camray Combi", "90/130 B", "", "", "obsolete", "4", "0", "0", "2", "0", "", "", "1", "2", "1", "26", "38", "", "", "71.0", "62.0", "", "43.2", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 938, "brand_name": "Boulter", "model_name": "Camray Quartet", "model_qualifier": "40/60 B", "winter_efficiency_pct": 70.0, "summer_efficiency_pct": 58.0, "comparative_hot_water_efficiency_pct": 42.6, "output_kw_max": 17.0, "final_year_of_manufacture": null, "raw": ["000938", "000041", "0", "2010/Sep/13 17:03", "Boulter Boilers", "Boulter", "Camray Quartet", "40/60 B", "", "", "obsolete", "4", "0", "0", "1", "0", "", "", "1", "2", "1", "12", "17", "", "", "70.0", "58.0", "", "42.6", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 939, "brand_name": "Boulter", "model_name": "Camray Quartet", "model_qualifier": "40/60 F", "winter_efficiency_pct": 70.0, "summer_efficiency_pct": 58.0, "comparative_hot_water_efficiency_pct": 42.6, "output_kw_max": 17.0, "final_year_of_manufacture": null, "raw": ["000939", "000041", "0", "2010/Sep/13 17:03", "Boulter Boilers", "Boulter", "Camray Quartet", "40/60 F", "", "", "obsolete", "4", "0", "0", "1", "0", "", "", "1", "2", "2", "12", "17", "", "", "70.0", "58.0", "", "42.6", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 940, "brand_name": "Boulter", "model_name": "Camray Quartet", "model_qualifier": "60/80 F", "winter_efficiency_pct": 70.0, "summer_efficiency_pct": 58.0, "comparative_hot_water_efficiency_pct": 42.6, "output_kw_max": 23.0, "final_year_of_manufacture": null, "raw": ["000940", "000041", "0", "2010/Sep/13 17:03", "Boulter Boilers", "Boulter", "Camray Quartet", "60/80 F", "", "", "obsolete", "4", "0", "0", "1", "0", "", "", "1", "2", "2", "17", "23", "", "", "70.0", "58.0", "", "42.6", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 941, "brand_name": "Boulter", "model_name": "Camray Quartet", "model_qualifier": "60/80 B", "winter_efficiency_pct": 70.0, "summer_efficiency_pct": 58.0, "comparative_hot_water_efficiency_pct": 42.6, "output_kw_max": 23.0, "final_year_of_manufacture": null, "raw": ["000941", "000041", "0", "2010/Sep/13 17:03", "Boulter Boilers", "Boulter", "Camray Quartet", "60/80 B", "", "", "obsolete", "4", "0", "0", "1", "0", "", "", "1", "2", "1", "17", "23", "", "", "70.0", "58.0", "", "42.6", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 942, "brand_name": "Boulter", "model_name": "Camray Quartet", "model_qualifier": "90/110 F", "winter_efficiency_pct": 70.0, "summer_efficiency_pct": 58.0, "comparative_hot_water_efficiency_pct": 42.6, "output_kw_max": 32.0, "final_year_of_manufacture": null, "raw": ["000942", "000041", "0", "2010/Sep/13 17:03", "Boulter Boilers", "Boulter", "Camray Quartet", "90/110 F", "", "", "obsolete", "4", "0", "0", "1", "0", "", "", "1", "2", "2", "26", "32", "", "", "70.0", "58.0", "", "42.6", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 943, "brand_name": "Boulter", "model_name": "Camray Quartet", "model_qualifier": "90/110 B", "winter_efficiency_pct": 70.0, "summer_efficiency_pct": 58.0, "comparative_hot_water_efficiency_pct": 42.6, "output_kw_max": 32.0, "final_year_of_manufacture": null, "raw": ["000943", "000041", "0", "2010/Sep/13 17:03", "Boulter Boilers", "Boulter", "Camray Quartet", "90/110 B", "", "", "obsolete", "4", "0", "0", "1", "0", "", "", "1", "2", "1", "26", "32", "", "", "70.0", "58.0", "", "42.6", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 944, "brand_name": "Boulter", "model_name": "Camray Quartet", "model_qualifier": "110/150 F", "winter_efficiency_pct": 70.0, "summer_efficiency_pct": 58.0, "comparative_hot_water_efficiency_pct": 42.6, "output_kw_max": 44.0, "final_year_of_manufacture": null, "raw": ["000944", "000041", "0", "2010/Sep/13 17:03", "Boulter Boilers", "Boulter", "Camray Quartet", "110/150 F", "", "", "obsolete", "4", "0", "0", "1", "0", "", "", "1", "2", "2", "32", "44", "", "", "70.0", "58.0", "", "42.6", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 945, "brand_name": "Boulter", "model_name": "Camray Quartet", "model_qualifier": "110/150 B", "winter_efficiency_pct": 70.0, "summer_efficiency_pct": 58.0, "comparative_hot_water_efficiency_pct": 42.6, "output_kw_max": 44.0, "final_year_of_manufacture": null, "raw": ["000945", "000041", "0", "2010/Sep/13 17:03", "Boulter Boilers", "Boulter", "Camray Quartet", "110/150 B", "", "", "obsolete", "4", "0", "0", "1", "0", "", "", "1", "2", "1", "32", "44", "", "", "70.0", "58.0", "", "42.6", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 946, "brand_name": "Boulter", "model_name": "Camray Utility", "model_qualifier": "40/60 B", "winter_efficiency_pct": 70.0, "summer_efficiency_pct": 58.0, "comparative_hot_water_efficiency_pct": 42.6, "output_kw_max": 17.0, "final_year_of_manufacture": null, "raw": ["000946", "000041", "0", "2010/Sep/13 17:03", "Boulter Boilers", "Boulter", "Camray Utility", "40/60 B", "", "", "obsolete", "4", "0", "0", "1", "0", "", "", "1", "2", "1", "12", "17", "", "", "70.0", "58.0", "", "42.6", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 947, "brand_name": "Boulter", "model_name": "Camray Utility", "model_qualifier": "40/60 F", "winter_efficiency_pct": 70.0, "summer_efficiency_pct": 58.0, "comparative_hot_water_efficiency_pct": 42.6, "output_kw_max": 17.0, "final_year_of_manufacture": null, "raw": ["000947", "000041", "0", "2010/Sep/13 17:03", "Boulter Boilers", "Boulter", "Camray Utility", "40/60 F", "", "", "obsolete", "4", "0", "0", "1", "0", "", "", "1", "2", "2", "12", "17", "", "", "70.0", "58.0", "", "42.6", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 948, "brand_name": "Boulter", "model_name": "Camray Utility", "model_qualifier": "60/80 F", "winter_efficiency_pct": 70.0, "summer_efficiency_pct": 58.0, "comparative_hot_water_efficiency_pct": 42.6, "output_kw_max": 23.0, "final_year_of_manufacture": null, "raw": ["000948", "000041", "0", "2010/Sep/13 17:03", "Boulter Boilers", "Boulter", "Camray Utility", "60/80 F", "", "", "obsolete", "4", "0", "0", "1", "0", "", "", "1", "2", "2", "17", "23", "", "", "70.0", "58.0", "", "42.6", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 949, "brand_name": "Boulter", "model_name": "Camray Utility", "model_qualifier": "60/80 B", "winter_efficiency_pct": 70.0, "summer_efficiency_pct": 58.0, "comparative_hot_water_efficiency_pct": 42.6, "output_kw_max": 23.0, "final_year_of_manufacture": null, "raw": ["000949", "000041", "0", "2010/Sep/13 17:03", "Boulter Boilers", "Boulter", "Camray Utility", "60/80 B", "", "", "obsolete", "4", "0", "0", "1", "0", "", "", "1", "2", "1", "17", "23", "", "", "70.0", "58.0", "", "42.6", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 950, "brand_name": "Boulter", "model_name": "Camray Utility", "model_qualifier": "90/110 F", "winter_efficiency_pct": 70.0, "summer_efficiency_pct": 58.0, "comparative_hot_water_efficiency_pct": 42.6, "output_kw_max": 32.0, "final_year_of_manufacture": null, "raw": ["000950", "000041", "0", "2010/Sep/13 17:03", "Boulter Boilers", "Boulter", "Camray Utility", "90/110 F", "", "", "obsolete", "4", "0", "0", "1", "0", "", "", "1", "2", "2", "26", "32", "", "", "70.0", "58.0", "", "42.6", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 951, "brand_name": "Boulter", "model_name": "Camray Utility", "model_qualifier": "90/110 B", "winter_efficiency_pct": 70.0, "summer_efficiency_pct": 58.0, "comparative_hot_water_efficiency_pct": 42.6, "output_kw_max": 32.0, "final_year_of_manufacture": null, "raw": ["000951", "000041", "0", "2010/Sep/13 17:03", "Boulter Boilers", "Boulter", "Camray Utility", "90/110 B", "", "", "obsolete", "4", "0", "0", "1", "0", "", "", "1", "2", "1", "26", "32", "", "", "70.0", "58.0", "", "42.6", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 952, "brand_name": "Boulter", "model_name": "Camray Utility", "model_qualifier": "110/150 F", "winter_efficiency_pct": 70.0, "summer_efficiency_pct": 58.0, "comparative_hot_water_efficiency_pct": 42.6, "output_kw_max": 44.0, "final_year_of_manufacture": null, "raw": ["000952", "000041", "0", "2010/Sep/13 17:03", "Boulter Boilers", "Boulter", "Camray Utility", "110/150 F", "", "", "obsolete", "4", "0", "0", "1", "0", "", "", "1", "2", "2", "32", "44", "", "", "70.0", "58.0", "", "42.6", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 953, "brand_name": "Boulter", "model_name": "Camray Utility", "model_qualifier": "110/150 B", "winter_efficiency_pct": 70.0, "summer_efficiency_pct": 58.0, "comparative_hot_water_efficiency_pct": 42.6, "output_kw_max": 44.0, "final_year_of_manufacture": null, "raw": ["000953", "000041", "0", "2010/Sep/13 17:03", "Boulter Boilers", "Boulter", "Camray Utility", "110/150 B", "", "", "obsolete", "4", "0", "0", "1", "0", "", "", "1", "2", "1", "32", "44", "", "", "70.0", "58.0", "", "42.6", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 954, "brand_name": "Boulter", "model_name": "Economy", "model_qualifier": "50/70", "winter_efficiency_pct": 70.0, "summer_efficiency_pct": 58.0, "comparative_hot_water_efficiency_pct": 42.6, "output_kw_max": 21.0, "final_year_of_manufacture": null, "raw": ["000954", "000041", "0", "2010/Sep/13 17:03", "Boulter Boilers", "Boulter", "Economy", "50/70", "", "", "obsolete", "4", "0", "0", "1", "0", "", "", "1", "2", "2", "15", "21", "", "", "70.0", "58.0", "", "42.6", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 955, "brand_name": "Boulter", "model_name": "Economy", "model_qualifier": "70/90", "winter_efficiency_pct": 70.0, "summer_efficiency_pct": 58.0, "comparative_hot_water_efficiency_pct": 42.6, "output_kw_max": 26.0, "final_year_of_manufacture": null, "raw": ["000955", "000041", "0", "2010/Sep/13 17:03", "Boulter Boilers", "Boulter", "Economy", "70/90", "", "", "obsolete", "4", "0", "0", "1", "0", "", "", "1", "2", "2", "21", "26", "", "", "70.0", "58.0", "", "42.6", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 958, "brand_name": "Boulter", "model_name": "Economy", "model_qualifier": "90", "winter_efficiency_pct": 71.0, "summer_efficiency_pct": 62.0, "comparative_hot_water_efficiency_pct": 43.2, "output_kw_max": 26.0, "final_year_of_manufacture": null, "raw": ["000958", "000041", "0", "2010/Sep/13 17:03", "Boulter Boilers", "Boulter", "Economy", "90", "", "", "obsolete", "4", "0", "0", "2", "0", "", "", "1", "2", "2", "26", "26", "", "", "71.0", "62.0", "", "43.2", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 959, "brand_name": "Boulter", "model_name": "Economy", "model_qualifier": "130", "winter_efficiency_pct": 71.0, "summer_efficiency_pct": 62.0, "comparative_hot_water_efficiency_pct": 43.2, "output_kw_max": 38.0, "final_year_of_manufacture": null, "raw": ["000959", "000041", "0", "2010/Sep/13 17:03", "Boulter Boilers", "Boulter", "Economy", "130", "", "", "obsolete", "4", "0", "0", "2", "0", "", "", "1", "2", "2", "38", "38", "", "", "71.0", "62.0", "", "43.2", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 970, "brand_name": "Charles Portway & Son", "model_name": "Portway Inset Trio", "model_qualifier": "", "winter_efficiency_pct": 65.0, "summer_efficiency_pct": 53.0, "comparative_hot_water_efficiency_pct": 38.9, "output_kw_max": 8.5, "final_year_of_manufacture": null, "raw": ["000970", "000140", "0", "2010/Sep/13 17:03", "Charles Portway & Son", "Charles Portway & Son", "Portway Inset Trio", "", "", "", "obsolete", "4", "0", "0", "1", "0", "", "", "1", "1", "1", "8.5", "8.5", "", "", "65.0", "53.0", "", "38.9", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 971, "brand_name": "Charles Portway & Son", "model_name": "Portway Trio MkIV", "model_qualifier": "", "winter_efficiency_pct": 65.0, "summer_efficiency_pct": 53.0, "comparative_hot_water_efficiency_pct": 38.9, "output_kw_max": 8.5, "final_year_of_manufacture": null, "raw": ["000971", "000140", "0", "2010/Sep/13 17:03", "Charles Portway & Son", "Charles Portway & Son", "Portway Trio MkIV", "", "", "", "obsolete", "4", "0", "0", "1", "0", "", "", "1", "1", "1", "8.5", "8.5", "", "", "65.0", "53.0", "", "38.9", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 972, "brand_name": "Charles Portway & Son", "model_name": "Portway Tortoisaire MkIII", "model_qualifier": "", "winter_efficiency_pct": 65.0, "summer_efficiency_pct": 53.0, "comparative_hot_water_efficiency_pct": 38.9, "output_kw_max": 11.5, "final_year_of_manufacture": null, "raw": ["000972", "000140", "0", "2010/Sep/13 17:03", "Charles Portway & Son", "Charles Portway & Son", "Portway Tortoisaire MkIII", "", "", "", "obsolete", "4", "0", "0", "1", "0", "", "", "1", "1", "1", "11.5", "11.5", "", "", "65.0", "53.0", "", "38.9", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 973, "brand_name": "Charles Portway & Son", "model_name": "Portway Visaire", "model_qualifier": "", "winter_efficiency_pct": 65.0, "summer_efficiency_pct": 53.0, "comparative_hot_water_efficiency_pct": 38.9, "output_kw_max": 8.5, "final_year_of_manufacture": null, "raw": ["000973", "000140", "0", "2010/Sep/13 17:03", "Charles Portway & Son", "Charles Portway & Son", "Portway Visaire", "", "", "", "obsolete", "4", "0", "0", "1", "0", "", "", "1", "1", "1", "8.5", "8.5", "", "", "65.0", "53.0", "", "38.9", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 974, "brand_name": "Charles Portway & Son", "model_name": "Portway", "model_qualifier": "40F", "winter_efficiency_pct": 65.0, "summer_efficiency_pct": 53.0, "comparative_hot_water_efficiency_pct": 38.9, "output_kw_max": 11.1, "final_year_of_manufacture": null, "raw": ["000974", "000140", "0", "2010/Sep/13 17:03", "Charles Portway & Son", "Charles Portway & Son", "Portway", "40F", "", "", "obsolete", "4", "0", "0", "1", "0", "", "", "1", "1", "1", "11.1", "11.1", "", "", "65.0", "53.0", "", "38.9", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 986, "brand_name": "Heating World Group", "model_name": "Beta", "model_qualifier": "42339", "winter_efficiency_pct": 70.0, "summer_efficiency_pct": 58.0, "comparative_hot_water_efficiency_pct": 42.6, "output_kw_max": 15.0, "final_year_of_manufacture": 1992, "raw": ["000986", "000050", "0", "2010/Sep/13 17:03", "Heating World Group", "Heating World Group", "Beta", "42339", "", "", "1992", "4", "0", "0", "1", "0", "", "", "1", "2", "2", "12", "15", "", "", "70.0", "58.0", "", "42.6", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 988, "brand_name": "Heating World Group", "model_name": "Beta", "model_qualifier": "15/19", "winter_efficiency_pct": 70.0, "summer_efficiency_pct": 58.0, "comparative_hot_water_efficiency_pct": 42.6, "output_kw_max": 19.0, "final_year_of_manufacture": 1991, "raw": ["000988", "000050", "0", "2010/Sep/13 17:03", "Heating World Group", "Heating World Group", "Beta", "15/19", "", "", "1991", "4", "0", "0", "1", "0", "", "", "1", "2", "2", "15", "19", "", "", "70.0", "58.0", "", "42.6", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 989, "brand_name": "Heating World Group", "model_name": "Beta", "model_qualifier": "15/17 WM", "winter_efficiency_pct": 70.0, "summer_efficiency_pct": 58.0, "comparative_hot_water_efficiency_pct": 42.6, "output_kw_max": 17.0, "final_year_of_manufacture": 1991, "raw": ["000989", "000050", "0", "2010/Sep/13 17:03", "Heating World Group", "Heating World Group", "Beta", "15/17 WM", "", "", "1991", "4", "0", "0", "1", "0", "", "", "1", "2", "2", "15", "17", "", "", "70.0", "58.0", "", "42.6", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1044, "brand_name": "Husqvarna", "model_name": "Husqvarna", "model_qualifier": "8AW/D", "winter_efficiency_pct": 65.0, "summer_efficiency_pct": 53.0, "comparative_hot_water_efficiency_pct": 38.9, "output_kw_max": 9.7, "final_year_of_manufacture": 1978, "raw": ["001044", "000140", "0", "2010/Sep/13 17:03", "Husqvarna", "Husqvarna", "Husqvarna", "8AW/D", "", "", "1978", "4", "0", "0", "1", "0", "", "", "1", "1", "1", "9.7", "9.7", "", "", "65.0", "53.0", "", "38.9", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1064, "brand_name": "Perrymatics", "model_name": "Perrymatic", "model_qualifier": "50", "winter_efficiency_pct": 65.0, "summer_efficiency_pct": 53.0, "comparative_hot_water_efficiency_pct": 38.9, "output_kw_max": 14.6, "final_year_of_manufacture": null, "raw": ["001064", "000040", "0", "2010/Sep/13 17:03", "Perrymatics", "Perrymatics", "Perrymatic", "50", "", "", "obsolete", "4", "0", "0", "1", "0", "", "", "1", "1", "1", "14.6", "14.6", "", "", "65.0", "53.0", "", "38.9", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1066, "brand_name": "Perrymatics", "model_name": "Perrymatic", "model_qualifier": "50/60", "winter_efficiency_pct": 65.0, "summer_efficiency_pct": 53.0, "comparative_hot_water_efficiency_pct": 38.9, "output_kw_max": 17.6, "final_year_of_manufacture": null, "raw": ["001066", "000040", "0", "2010/Sep/13 17:03", "Perrymatics", "Perrymatics", "Perrymatic", "50/60", "", "", "obsolete", "4", "0", "0", "1", "0", "", "", "1", "1", "1", "14.6", "17.6", "", "", "65.0", "53.0", "", "38.9", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1067, "brand_name": "Perrymatics", "model_name": "Perrymatic", "model_qualifier": "80", "winter_efficiency_pct": 65.0, "summer_efficiency_pct": 53.0, "comparative_hot_water_efficiency_pct": 38.9, "output_kw_max": 23.4, "final_year_of_manufacture": null, "raw": ["001067", "000040", "0", "2010/Sep/13 17:03", "Perrymatics", "Perrymatics", "Perrymatic", "80", "", "", "obsolete", "4", "0", "0", "1", "0", "", "", "1", "1", "1", "23.4", "23.4", "", "", "65.0", "53.0", "", "38.9", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1068, "brand_name": "Perrymatics", "model_name": "Perrymatic", "model_qualifier": "95", "winter_efficiency_pct": 65.0, "summer_efficiency_pct": 53.0, "comparative_hot_water_efficiency_pct": 38.9, "output_kw_max": 27.8, "final_year_of_manufacture": null, "raw": ["001068", "000040", "0", "2010/Sep/13 17:03", "Perrymatics", "Perrymatics", "Perrymatic", "95", "", "", "obsolete", "4", "0", "0", "1", "0", "", "", "1", "1", "1", "27.8", "27.8", "", "", "65.0", "53.0", "", "38.9", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1071, "brand_name": "Perrymatics", "model_name": "Perrymatic Jetstreme Mk1", "model_qualifier": "", "winter_efficiency_pct": 65.0, "summer_efficiency_pct": 53.0, "comparative_hot_water_efficiency_pct": 38.9, "output_kw_max": 26.4, "final_year_of_manufacture": null, "raw": ["001071", "000040", "0", "2010/Sep/13 17:03", "Perrymatics", "Perrymatics", "Perrymatic Jetstreme Mk1", "", "", "", "obsolete", "4", "0", "0", "1", "0", "", "", "1", "2", "2", "20.5", "26.4", "", "", "65.0", "53.0", "", "38.9", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1072, "brand_name": "Potterton International Heating", "model_name": "35Bf", "model_qualifier": "35bf", "winter_efficiency_pct": 56.0, "summer_efficiency_pct": 46.0, "comparative_hot_water_efficiency_pct": 33.5, "output_kw_max": 9.7, "final_year_of_manufacture": 1976, "raw": ["001072", "000005", "0", "2010/Sep/13 17:03", "Potterton International Heating", "Potterton International Heating", "35Bf", "35bf", "4178914", "", "1976", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "9.7", "9.7", "", "", "56.0", "46.0", "", "33.5", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1073, "brand_name": "Potterton Myson Heating", "model_name": "35Bf", "model_qualifier": "35bf", "winter_efficiency_pct": 56.0, "summer_efficiency_pct": 46.0, "comparative_hot_water_efficiency_pct": 33.5, "output_kw_max": 9.7, "final_year_of_manufacture": 1978, "raw": ["001073", "000005", "0", "2010/Sep/13 17:03", "Potterton Myson Heating", "Potterton Myson Heating", "35Bf", "35bf", "4178914", "", "1978", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "9.7", "9.7", "", "", "56.0", "46.0", "", "33.5", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1074, "brand_name": "Potterton Myson Heating", "model_name": "35Cf", "model_qualifier": "35cf", "winter_efficiency_pct": 56.0, "summer_efficiency_pct": 46.0, "comparative_hot_water_efficiency_pct": 33.5, "output_kw_max": 9.7, "final_year_of_manufacture": 1976, "raw": ["001074", "000005", "0", "2010/Sep/13 17:03", "Potterton Myson Heating", "Potterton Myson Heating", "35Cf", "35cf", "4178926", "", "1976", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "9.7", "9.7", "", "", "56.0", "46.0", "", "33.5", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1075, "brand_name": "Potterton International Heating", "model_name": "35Cf", "model_qualifier": "35cf", "winter_efficiency_pct": 56.0, "summer_efficiency_pct": 46.0, "comparative_hot_water_efficiency_pct": 33.5, "output_kw_max": 9.7, "final_year_of_manufacture": 1976, "raw": ["001075", "000005", "0", "2010/Sep/13 17:03", "Potterton International Heating", "Potterton International Heating", "35Cf", "35cf", "4178913", "", "1976", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "9.7", "9.7", "", "", "56.0", "46.0", "", "33.5", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1076, "brand_name": "Thorn EMI Heating", "model_name": "Apollo", "model_qualifier": "15/30b", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 8.8, "final_year_of_manufacture": 1990, "raw": ["001076", "000005", "0", "2010/Sep/13 17:03", "Thorn EMI Heating", "Thorn EMI Heating", "Apollo", "15/30b", "4178953", "", "1990", "1", "2", "1", "1", "0", "", "", "1", "2", "1", "4.4", "8.8", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "1", "20", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1077, "brand_name": "Thorn EMI Heating", "model_name": "Apollo", "model_qualifier": "15/30c", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 8.8, "final_year_of_manufacture": 1990, "raw": ["001077", "000005", "0", "2010/Sep/13 17:03", "Thorn EMI Heating", "Thorn EMI Heating", "Apollo", "15/30c", "4178955", "", "1990", "1", "2", "1", "1", "0", "", "", "1", "1", "1", "4.4", "8.8", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "1", "20", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1078, "brand_name": "Thorn EMI Heating", "model_name": "Apollo", "model_qualifier": "30/50b", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 14.7, "final_year_of_manufacture": 1990, "raw": ["001078", "000005", "0", "2010/Sep/13 17:03", "Thorn EMI Heating", "Thorn EMI Heating", "Apollo", "30/50b", "4178954", "", "1990", "1", "2", "1", "1", "0", "", "", "1", "2", "1", "8.8", "14.7", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "1", "60", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1079, "brand_name": "Potterton Myson Heating", "model_name": "Apollo", "model_qualifier": "30/50c", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 14.7, "final_year_of_manufacture": 1990, "raw": ["001079", "000005", "0", "2010/Sep/13 17:03", "Potterton Myson Heating", "Potterton Myson Heating", "Apollo", "30/50c", "4178956", "", "1990", "1", "2", "1", "1", "0", "", "", "1", "1", "1", "8.8", "14.7", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "1", "60", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1080, "brand_name": "Thorn EMI Heating", "model_name": "Apollo", "model_qualifier": "30/50s", "winter_efficiency_pct": 73.0, "summer_efficiency_pct": 63.0, "comparative_hot_water_efficiency_pct": 45.9, "output_kw_max": 14.7, "final_year_of_manufacture": 1990, "raw": ["001080", "000005", "0", "2015/Jul/21 14:15", "Thorn EMI Heating", "Thorn EMI Heating", "Apollo", "30/50s", "4149406", "", "1990", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "8.8", "14.7", "", "", "73.0", "63.0", "", "45.9", "", "3", "", "", "0", "2", "1", "60", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1084, "brand_name": "Thorn EMI Heating", "model_name": "Apollo", "model_qualifier": "50/65b", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 19.1, "final_year_of_manufacture": 1990, "raw": ["001084", "000005", "0", "2010/Sep/13 17:03", "Thorn EMI Heating", "Thorn EMI Heating", "Apollo", "50/65b", "4178967", "", "1990", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "19.1", "19.1", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1085, "brand_name": "Thorn EMI Heating", "model_name": "Apollo", "model_qualifier": "50/65c", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 19.1, "final_year_of_manufacture": 1990, "raw": ["001085", "000005", "0", "2010/Sep/13 17:03", "Thorn EMI Heating", "Thorn EMI Heating", "Apollo", "50/65c", "4178968", "", "1990", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "14.7", "19.1", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1086, "brand_name": "Thorn EMI Heating", "model_name": "Apollo", "model_qualifier": "50/80b", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 23.4, "final_year_of_manufacture": 1983, "raw": ["001086", "000005", "0", "2010/Sep/13 17:03", "Thorn EMI Heating", "Thorn EMI Heating", "Apollo", "50/80b", "4178963", "", "1983", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "23.4", "23.4", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1087, "brand_name": "Thorn EMI Heating", "model_name": "Apollo", "model_qualifier": "50/80c", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 23.4, "final_year_of_manufacture": 1983, "raw": ["001087", "000005", "0", "2010/Sep/13 17:03", "Thorn EMI Heating", "Thorn EMI Heating", "Apollo", "50/80c", "4178964", "", "1983", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "23.4", "23.4", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1088, "brand_name": "Thorn EMI Heating", "model_name": "Apollo", "model_qualifier": "65/80b", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 23.4, "final_year_of_manufacture": 1990, "raw": ["001088", "000005", "0", "2010/Sep/13 17:03", "Thorn EMI Heating", "Thorn EMI Heating", "Apollo", "65/80b", "4178969", "", "1990", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "23.4", "23.4", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1089, "brand_name": "Thorn EMI Heating", "model_name": "Apollo", "model_qualifier": "65/80c", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 23.4, "final_year_of_manufacture": 1990, "raw": ["001089", "000005", "0", "2010/Sep/13 17:03", "Thorn EMI Heating", "Thorn EMI Heating", "Apollo", "65/80c", "4178970", "", "1990", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "23.4", "23.4", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1090, "brand_name": "Potterton Myson Heating", "model_name": "Apollo Fanfare", "model_qualifier": "15/30", "winter_efficiency_pct": 73.0, "summer_efficiency_pct": 63.0, "comparative_hot_water_efficiency_pct": 45.9, "output_kw_max": 8.8, "final_year_of_manufacture": 1987, "raw": ["001090", "000005", "0", "2015/Jul/21 14:15", "Potterton Myson Heating", "Potterton Myson Heating", "Apollo Fanfare", "15/30", "4178971", "", "1987", "1", "0", "0", "1", "0", "", "", "1", "2", "2", "8.8", "8.8", "", "", "73.0", "63.0", "", "45.9", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1091, "brand_name": "Potterton Myson Heating", "model_name": "Apollo Fanfare", "model_qualifier": "15/30i", "winter_efficiency_pct": 73.0, "summer_efficiency_pct": 63.0, "comparative_hot_water_efficiency_pct": 45.9, "output_kw_max": 8.8, "final_year_of_manufacture": 1987, "raw": ["001091", "000005", "0", "2015/Jul/21 14:15", "Potterton Myson Heating", "Potterton Myson Heating", "Apollo Fanfare", "15/30i", "4178973", "", "1987", "1", "0", "0", "1", "0", "", "", "1", "2", "2", "8.8", "8.8", "", "", "73.0", "63.0", "", "45.9", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1092, "brand_name": "Thorn EMI Heating", "model_name": "Apollo Fanfare", "model_qualifier": "15/30s", "winter_efficiency_pct": 73.0, "summer_efficiency_pct": 63.0, "comparative_hot_water_efficiency_pct": 45.9, "output_kw_max": 8.8, "final_year_of_manufacture": 1990, "raw": ["001092", "000005", "0", "2015/Jul/21 14:15", "Thorn EMI Heating", "Thorn EMI Heating", "Apollo Fanfare", "15/30s", "4149405", "", "1990", "1", "0", "0", "1", "0", "", "", "1", "2", "2", "8.8", "8.8", "", "", "73.0", "63.0", "", "45.9", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1093, "brand_name": "Thorn EMI Heating", "model_name": "Apollo Fanfare", "model_qualifier": "15/30si", "winter_efficiency_pct": 73.0, "summer_efficiency_pct": 63.0, "comparative_hot_water_efficiency_pct": 45.9, "output_kw_max": 8.8, "final_year_of_manufacture": 1990, "raw": ["001093", "000005", "0", "2015/Jul/21 14:15", "Thorn EMI Heating", "Thorn EMI Heating", "Apollo Fanfare", "15/30si", "4179503", "", "1990", "1", "0", "0", "1", "0", "", "", "1", "2", "2", "8.8", "8.8", "", "", "73.0", "63.0", "", "45.9", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1094, "brand_name": "Potterton Myson Heating", "model_name": "Apollo Fanfare", "model_qualifier": "30/50", "winter_efficiency_pct": 73.0, "summer_efficiency_pct": 63.0, "comparative_hot_water_efficiency_pct": 45.9, "output_kw_max": 14.7, "final_year_of_manufacture": 1987, "raw": ["001094", "000005", "0", "2015/Jul/21 14:15", "Potterton Myson Heating", "Potterton Myson Heating", "Apollo Fanfare", "30/50", "4178972", "", "1987", "1", "0", "0", "1", "0", "", "", "1", "2", "2", "14.7", "14.7", "", "", "73.0", "63.0", "", "45.9", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1095, "brand_name": "Potterton Myson Heating", "model_name": "Apollo Fanfare", "model_qualifier": "30/50i", "winter_efficiency_pct": 73.0, "summer_efficiency_pct": 63.0, "comparative_hot_water_efficiency_pct": 45.9, "output_kw_max": 14.7, "final_year_of_manufacture": 1987, "raw": ["001095", "000005", "0", "2015/Jul/21 14:15", "Potterton Myson Heating", "Potterton Myson Heating", "Apollo Fanfare", "30/50i", "4178974", "", "1987", "1", "0", "0", "1", "0", "", "", "1", "2", "2", "14.7", "14.7", "", "", "73.0", "63.0", "", "45.9", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1096, "brand_name": "Thorn EMI Heating", "model_name": "Apollo Fanfare", "model_qualifier": "30/50si", "winter_efficiency_pct": 73.0, "summer_efficiency_pct": 63.0, "comparative_hot_water_efficiency_pct": 45.9, "output_kw_max": 14.7, "final_year_of_manufacture": 1990, "raw": ["001096", "000005", "0", "2015/Jul/21 14:15", "Thorn EMI Heating", "Thorn EMI Heating", "Apollo Fanfare", "30/50si", "4179504", "", "1990", "1", "0", "0", "1", "0", "", "", "1", "2", "2", "14.7", "14.7", "", "", "73.0", "63.0", "", "45.9", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1097, "brand_name": "Thorn EMI Heating", "model_name": "Apollo Fanfare", "model_qualifier": "40si", "winter_efficiency_pct": 73.0, "summer_efficiency_pct": 63.0, "comparative_hot_water_efficiency_pct": 45.9, "output_kw_max": 11.7, "final_year_of_manufacture": 1990, "raw": ["001097", "000005", "0", "2015/Jul/21 14:15", "Thorn EMI Heating", "Thorn EMI Heating", "Apollo Fanfare", "40si", "4179505", "", "1990", "1", "0", "0", "1", "0", "", "", "1", "2", "2", "11.7", "11.7", "", "", "73.0", "63.0", "", "45.9", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1098, "brand_name": "Thorn EMI Heating", "model_name": "Apollo Fanfare", "model_qualifier": "50/65si", "winter_efficiency_pct": 73.0, "summer_efficiency_pct": 63.0, "comparative_hot_water_efficiency_pct": 45.9, "output_kw_max": 19.1, "final_year_of_manufacture": 1990, "raw": ["001098", "000005", "0", "2015/Jul/21 14:15", "Thorn EMI Heating", "Thorn EMI Heating", "Apollo Fanfare", "50/65si", "4178976", "", "1990", "1", "0", "0", "1", "0", "", "", "1", "2", "2", "19.1", "19.1", "", "", "73.0", "63.0", "", "45.9", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1099, "brand_name": "Thorn EMI Heating", "model_name": "Apollo Fanfare", "model_qualifier": "65/80si", "winter_efficiency_pct": 73.0, "summer_efficiency_pct": 63.0, "comparative_hot_water_efficiency_pct": 45.9, "output_kw_max": 23.4, "final_year_of_manufacture": 1990, "raw": ["001099", "000005", "0", "2015/Jul/21 14:15", "Thorn EMI Heating", "Thorn EMI Heating", "Apollo Fanfare", "65/80si", "4178975", "", "1990", "1", "0", "0", "1", "0", "", "", "1", "2", "2", "23.4", "23.4", "", "", "73.0", "63.0", "", "45.9", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1100, "brand_name": "Thorn EMI Heating", "model_name": "Gemini", "model_qualifier": "wm", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 57.0, "comparative_hot_water_efficiency_pct": 39.7, "output_kw_max": 14.7, "final_year_of_manufacture": 1988, "raw": ["001100", "000005", "0", "2010/Sep/13 17:03", "Thorn EMI Heating", "Thorn EMI Heating", "Gemini", "wm", "4778901", "", "1988", "1", "0", "0", "2", "0", "", "", "1", "2", "1", "14.7", "14.7", "", "", "66.0", "57.0", "", "39.7", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1102, "brand_name": "Thorn EMI Heating", "model_name": "International", "model_qualifier": "m42bf", "winter_efficiency_pct": 56.0, "summer_efficiency_pct": 46.0, "comparative_hot_water_efficiency_pct": 33.5, "output_kw_max": 11.7, "final_year_of_manufacture": 1976, "raw": ["001102", "000005", "0", "2010/Sep/13 17:03", "Thorn EMI Heating", "Thorn EMI Heating", "International", "m42bf", "4178904", "", "1976", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "11.7", "11.7", "", "", "56.0", "46.0", "", "33.5", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1104, "brand_name": "Thorn EMI Heating", "model_name": "International", "model_qualifier": "m42cf", "winter_efficiency_pct": 56.0, "summer_efficiency_pct": 46.0, "comparative_hot_water_efficiency_pct": 33.5, "output_kw_max": 11.7, "final_year_of_manufacture": 1976, "raw": ["001104", "000005", "0", "2010/Sep/13 17:03", "Thorn EMI Heating", "Thorn EMI Heating", "International", "m42cf", "4178908", "", "1976", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "11.7", "11.7", "", "", "56.0", "46.0", "", "33.5", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1106, "brand_name": "Thorn EMI Heating", "model_name": "International", "model_qualifier": "m54bf", "winter_efficiency_pct": 56.0, "summer_efficiency_pct": 46.0, "comparative_hot_water_efficiency_pct": 33.5, "output_kw_max": 14.7, "final_year_of_manufacture": null, "raw": ["001106", "000005", "0", "2010/Sep/13 17:03", "Thorn EMI Heating", "Thorn EMI Heating", "International", "m54bf", "4178911", "", "obsolete", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "14.7", "14.7", "", "", "56.0", "46.0", "", "33.5", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1108, "brand_name": "Thorn EMI Heating", "model_name": "International", "model_qualifier": "m54cf", "winter_efficiency_pct": 56.0, "summer_efficiency_pct": 46.0, "comparative_hot_water_efficiency_pct": 33.5, "output_kw_max": 14.7, "final_year_of_manufacture": 1976, "raw": ["001108", "000005", "0", "2010/Sep/13 17:03", "Thorn EMI Heating", "Thorn EMI Heating", "International", "m54cf", "4178903", "", "1976", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "14.7", "14.7", "", "", "56.0", "46.0", "", "33.5", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1109, "brand_name": "Potterton Myson Heating", "model_name": "Marathon", "model_qualifier": "100b", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 27.8, "final_year_of_manufacture": 1988, "raw": ["001109", "000005", "0", "2010/Sep/13 17:03", "Potterton Myson Heating", "Potterton Myson Heating", "Marathon", "100b", "4178985", "", "1988", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "27.8", "27.8", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1110, "brand_name": "Potterton Myson Heating", "model_name": "Marathon", "model_qualifier": "100c", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 27.8, "final_year_of_manufacture": 1988, "raw": ["001110", "000005", "0", "2010/Sep/13 17:03", "Potterton Myson Heating", "Potterton Myson Heating", "Marathon", "100c", "4178991", "", "1988", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "27.8", "27.8", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1111, "brand_name": "Potterton Myson Heating", "model_name": "Marathon", "model_qualifier": "120/150c", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 41.47, "final_year_of_manufacture": 1988, "raw": ["001111", "000005", "0", "2010/Sep/13 17:03", "Potterton Myson Heating", "Potterton Myson Heating", "Marathon", "120/150c", "4178952", "", "1988", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "41.47", "41.47", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1112, "brand_name": "Thorn EMI Heating", "model_name": "Marathon", "model_qualifier": "30/42b", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 12.3, "final_year_of_manufacture": 1983, "raw": ["001112", "000005", "0", "2010/Sep/13 17:03", "Thorn EMI Heating", "Thorn EMI Heating", "Marathon", "30/42b", "4178945", "", "1983", "1", "1", "1", "1", "0", "", "", "1", "2", "1", "8.8", "12.3", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "1", "20", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1113, "brand_name": "Thorn EMI Heating", "model_name": "Marathon", "model_qualifier": "30/42c", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 12.3, "final_year_of_manufacture": 1983, "raw": ["001113", "000005", "0", "2010/Sep/13 17:03", "Thorn EMI Heating", "Thorn EMI Heating", "Marathon", "30/42c", "4178944", "", "1983", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "8.8", "12.3", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "1", "20", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1114, "brand_name": "Potterton Myson Heating", "model_name": "Marathon", "model_qualifier": "40c", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 11.7, "final_year_of_manufacture": 1988, "raw": ["001114", "000005", "0", "2010/Sep/13 17:03", "Potterton Myson Heating", "Potterton Myson Heating", "Marathon", "40c", "4178986", "", "1988", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "11.7", "11.7", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1115, "brand_name": "Thorn EMI Heating", "model_name": "Marathon", "model_qualifier": "44/54b", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 15.8, "final_year_of_manufacture": 1983, "raw": ["001115", "000005", "0", "2010/Sep/13 17:03", "Thorn EMI Heating", "Thorn EMI Heating", "Marathon", "44/54b", "4178947", "", "1983", "1", "1", "1", "1", "0", "", "", "1", "2", "1", "12.9", "15.8", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "1", "20", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1116, "brand_name": "Thorn EMI Heating", "model_name": "Marathon", "model_qualifier": "44/54c", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 15.8, "final_year_of_manufacture": 1983, "raw": ["001116", "000005", "0", "2010/Sep/13 17:03", "Thorn EMI Heating", "Thorn EMI Heating", "Marathon", "44/54c", "4178946", "", "1983", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "12.9", "15.8", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "1", "20", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1117, "brand_name": "Potterton Myson Heating", "model_name": "Marathon", "model_qualifier": "50c", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 14.7, "final_year_of_manufacture": 1988, "raw": ["001117", "000005", "0", "2010/Sep/13 17:03", "Potterton Myson Heating", "Potterton Myson Heating", "Marathon", "50c", "4178987", "", "1988", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "14.7", "14.7", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1118, "brand_name": "Thorn EMI Heating", "model_name": "Marathon", "model_qualifier": "56/76b", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 21.1, "final_year_of_manufacture": 1983, "raw": ["001118", "000005", "0", "2010/Sep/13 17:03", "Thorn EMI Heating", "Thorn EMI Heating", "Marathon", "56/76b", "4178949", "", "1983", "1", "1", "1", "1", "0", "", "", "1", "2", "1", "21.1", "21.1", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "1", "20", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1119, "brand_name": "Thorn EMI Heating", "model_name": "Marathon", "model_qualifier": "56/76c", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 22.3, "final_year_of_manufacture": 1983, "raw": ["001119", "000005", "0", "2010/Sep/13 17:03", "Thorn EMI Heating", "Thorn EMI Heating", "Marathon", "56/76c", "4178948", "", "1983", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "16.4", "22.3", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "1", "20", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1120, "brand_name": "Potterton Myson Heating", "model_name": "Marathon", "model_qualifier": "60b", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 17.6, "final_year_of_manufacture": 1988, "raw": ["001120", "000005", "0", "2010/Sep/13 17:03", "Potterton Myson Heating", "Potterton Myson Heating", "Marathon", "60b", "4178982", "", "1988", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "17.6", "17.6", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1121, "brand_name": "Potterton Myson Heating", "model_name": "Marathon", "model_qualifier": "60c", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 17.6, "final_year_of_manufacture": 1988, "raw": ["001121", "000005", "0", "2010/Sep/13 17:03", "Potterton Myson Heating", "Potterton Myson Heating", "Marathon", "60c", "4178988", "", "1988", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "17.6", "17.6", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1122, "brand_name": "Potterton Myson Heating", "model_name": "Marathon", "model_qualifier": "70b", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 20.5, "final_year_of_manufacture": 1988, "raw": ["001122", "000005", "0", "2010/Sep/13 17:03", "Potterton Myson Heating", "Potterton Myson Heating", "Marathon", "70b", "4178983", "", "1988", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "20.5", "20.5", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1123, "brand_name": "Potterton Myson Heating", "model_name": "Marathon", "model_qualifier": "70c", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 20.5, "final_year_of_manufacture": 1988, "raw": ["001123", "000005", "0", "2010/Sep/13 17:03", "Potterton Myson Heating", "Potterton Myson Heating", "Marathon", "70c", "4178989", "", "1988", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "20.5", "20.5", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1124, "brand_name": "Thorn EMI Heating", "model_name": "Marathon", "model_qualifier": "80/100b", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 29.3, "final_year_of_manufacture": 1983, "raw": ["001124", "000005", "0", "2010/Sep/13 17:03", "Thorn EMI Heating", "Thorn EMI Heating", "Marathon", "80/100b", "4178951", "", "1983", "1", "1", "1", "1", "0", "", "", "1", "2", "1", "23.4", "29.3", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "1", "20", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1125, "brand_name": "Thorn EMI Heating", "model_name": "Marathon", "model_qualifier": "80/100c", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 29.3, "final_year_of_manufacture": 1983, "raw": ["001125", "000005", "0", "2010/Sep/13 17:03", "Thorn EMI Heating", "Thorn EMI Heating", "Marathon", "80/100c", "4178950", "", "1983", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "23.4", "29.3", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "1", "20", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1126, "brand_name": "Potterton Myson Heating", "model_name": "Marathon", "model_qualifier": "80b", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 23.5, "final_year_of_manufacture": 1988, "raw": ["001126", "000005", "0", "2010/Sep/13 17:03", "Potterton Myson Heating", "Potterton Myson Heating", "Marathon", "80b", "4178984", "", "1988", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "23.5", "23.5", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1127, "brand_name": "Potterton Myson Heating", "model_name": "Marathon", "model_qualifier": "80c", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 23.5, "final_year_of_manufacture": 1988, "raw": ["001127", "000005", "0", "2010/Sep/13 17:03", "Potterton Myson Heating", "Potterton Myson Heating", "Marathon", "80c", "4178990", "", "1988", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "23.5", "23.5", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1128, "brand_name": "Myson Combustion Products", "model_name": "Midas", "model_qualifier": "b", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 39.2, "output_kw_max": 20.5, "final_year_of_manufacture": 1991, "raw": ["001128", "000005", "0", "2010/Sep/13 17:03", "Myson Combustion Products", "Myson Combustion Products", "Midas", "b", "4783801", "", "1991", "1", "2", "1", "2", "0", "", "", "1", "2", "1", "20.5", "20.5", "", "", "66.0", "56.0", "", "39.2", "", "3", "", "", "0", "2", "2", "20", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1129, "brand_name": "Myson Combustion Products", "model_name": "Midas", "model_qualifier": "bf", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 39.2, "output_kw_max": 20.5, "final_year_of_manufacture": 1995, "raw": ["001129", "000005", "0", "2010/Sep/13 17:03", "Myson Combustion Products", "Myson Combustion Products", "Midas", "bf", "4749403", "", "1995", "1", "2", "1", "2", "0", "", "", "1", "2", "1", "20.5", "20.5", "", "", "66.0", "56.0", "", "39.2", "", "3", "", "", "0", "2", "2", "20", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1130, "brand_name": "Myson Combustion Products", "model_name": "Midas", "model_qualifier": "sfi", "winter_efficiency_pct": 71.0, "summer_efficiency_pct": 61.0, "comparative_hot_water_efficiency_pct": 42.8, "output_kw_max": 29.3, "final_year_of_manufacture": 1995, "raw": ["001130", "000005", "0", "2010/Sep/13 17:03", "Myson Combustion Products", "Myson Combustion Products", "Midas", "sfi", "4749404", "", "1995", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "29.3", "29.3", "", "", "71.0", "61.0", "", "42.8", "", "3", "", "", "0", "1", "2", "80", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1131, "brand_name": "Myson Combustion Products", "model_name": "Midas", "model_qualifier": "si", "winter_efficiency_pct": 71.0, "summer_efficiency_pct": 61.0, "comparative_hot_water_efficiency_pct": 42.8, "output_kw_max": 29.3, "final_year_of_manufacture": 1991, "raw": ["001131", "000005", "0", "2010/Sep/13 17:03", "Myson Combustion Products", "Myson Combustion Products", "Midas", "si", "4749402", "", "1991", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "29.3", "29.3", "", "", "71.0", "61.0", "", "42.8", "", "3", "", "", "0", "1", "2", "80", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1132, "brand_name": "Potterton Myson Heating", "model_name": "Olympic", "model_qualifier": "20/35b", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 10.26, "final_year_of_manufacture": 1987, "raw": ["001132", "000005", "0", "2010/Sep/13 17:03", "Potterton Myson Heating", "Potterton Myson Heating", "Olympic", "20/35b", "4178921", "", "1987", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "10.26", "10.26", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1133, "brand_name": "Potterton Myson Heating", "model_name": "Olympic", "model_qualifier": "20/35cf", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 10.26, "final_year_of_manufacture": 1987, "raw": ["001133", "000005", "0", "2010/Sep/13 17:03", "Potterton Myson Heating", "Potterton Myson Heating", "Olympic", "20/35cf", "4178942", "", "1987", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "10.26", "10.26", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1134, "brand_name": "Potterton Myson Heating", "model_name": "Olympic", "model_qualifier": "20/35f", "winter_efficiency_pct": 69.0, "summer_efficiency_pct": 59.0, "comparative_hot_water_efficiency_pct": 43.0, "output_kw_max": 10.26, "final_year_of_manufacture": 1987, "raw": ["001134", "000005", "0", "2010/Sep/13 17:03", "Potterton Myson Heating", "Potterton Myson Heating", "Olympic", "20/35f", "4178965", "", "1987", "1", "0", "0", "1", "0", "", "", "1", "2", "2", "10.26", "10.26", "", "", "69.0", "59.0", "", "43.0", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1135, "brand_name": "Potterton Myson Heating", "model_name": "Olympic", "model_qualifier": "38/50b", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 14.66, "final_year_of_manufacture": 1987, "raw": ["001135", "000005", "0", "2010/Sep/13 17:03", "Potterton Myson Heating", "Potterton Myson Heating", "Olympic", "38/50b", "4178920", "", "1987", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "14.66", "14.66", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1136, "brand_name": "Potterton Myson Heating", "model_name": "Olympic", "model_qualifier": "38/50cf", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 14.66, "final_year_of_manufacture": 1987, "raw": ["001136", "000005", "0", "2010/Sep/13 17:03", "Potterton Myson Heating", "Potterton Myson Heating", "Olympic", "38/50cf", "4178943", "", "1987", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "14.66", "14.66", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1137, "brand_name": "Potterton Myson Heating", "model_name": "Olympic", "model_qualifier": "38/50f", "winter_efficiency_pct": 69.0, "summer_efficiency_pct": 59.0, "comparative_hot_water_efficiency_pct": 43.0, "output_kw_max": 14.65, "final_year_of_manufacture": 1987, "raw": ["001137", "000005", "0", "2010/Sep/13 17:03", "Potterton Myson Heating", "Potterton Myson Heating", "Olympic", "38/50f", "4178966", "", "1987", "1", "0", "0", "1", "0", "", "", "1", "2", "2", "14.65", "14.65", "", "", "69.0", "59.0", "", "43.0", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1138, "brand_name": "Thorn EMI Heating", "model_name": "Orion", "model_qualifier": "30b", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 8.8, "final_year_of_manufacture": 1993, "raw": ["001138", "000005", "0", "2010/Sep/13 17:03", "Thorn EMI Heating", "Thorn EMI Heating", "Orion", "30b", "4178994", "", "1993", "1", "2", "1", "1", "0", "", "", "1", "2", "1", "8.8", "8.8", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "1", "20", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1139, "brand_name": "Thorn EMI Heating", "model_name": "Orion", "model_qualifier": "40b", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 11.7, "final_year_of_manufacture": 1993, "raw": ["001139", "000005", "0", "2010/Sep/13 17:03", "Thorn EMI Heating", "Thorn EMI Heating", "Orion", "40b", "4178995", "", "1993", "1", "2", "1", "1", "0", "", "", "1", "2", "1", "11.7", "11.7", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "1", "20", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1140, "brand_name": "Thorn EMI Heating", "model_name": "Orion", "model_qualifier": "50b", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 14.7, "final_year_of_manufacture": 1993, "raw": ["001140", "000005", "0", "2010/Sep/13 17:03", "Thorn EMI Heating", "Thorn EMI Heating", "Orion", "50b", "4178996", "", "1993", "1", "2", "1", "1", "0", "", "", "1", "2", "1", "14.7", "14.7", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "1", "20", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1141, "brand_name": "Thorn EMI Heating", "model_name": "Orion", "model_qualifier": "60b", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 17.6, "final_year_of_manufacture": 1993, "raw": ["001141", "000005", "0", "2010/Sep/13 17:03", "Thorn EMI Heating", "Thorn EMI Heating", "Orion", "60b", "4178997", "", "1993", "1", "2", "1", "1", "0", "", "", "1", "2", "1", "17.6", "17.6", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "1", "20", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1142, "brand_name": "Thorn EMI Heating", "model_name": "Orion", "model_qualifier": "75si", "winter_efficiency_pct": 69.0, "summer_efficiency_pct": 59.0, "comparative_hot_water_efficiency_pct": 43.0, "output_kw_max": 21.9, "final_year_of_manufacture": 1993, "raw": ["001142", "000005", "0", "2010/Sep/13 17:03", "Thorn EMI Heating", "Thorn EMI Heating", "Orion", "75si", "4149421", "", "1993", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "21.9", "21.9", "", "", "69.0", "59.0", "", "43.0", "", "3", "", "", "0", "1", "1", "80", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1143, "brand_name": "Thorn EMI Heating", "model_name": "Orion Fanfare", "model_qualifier": "30si", "winter_efficiency_pct": 69.0, "summer_efficiency_pct": 59.0, "comparative_hot_water_efficiency_pct": 43.0, "output_kw_max": 8.8, "final_year_of_manufacture": 1993, "raw": ["001143", "000005", "0", "2010/Sep/13 17:03", "Thorn EMI Heating", "Thorn EMI Heating", "Orion Fanfare", "30si", "4179506", "", "1993", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "8.8", "8.8", "", "", "69.0", "59.0", "", "43.0", "", "3", "", "", "0", "1", "1", "60", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1144, "brand_name": "Thorn EMI Heating", "model_name": "Orion Fanfare", "model_qualifier": "40si", "winter_efficiency_pct": 69.0, "summer_efficiency_pct": 59.0, "comparative_hot_water_efficiency_pct": 43.0, "output_kw_max": 11.7, "final_year_of_manufacture": 1993, "raw": ["001144", "000005", "0", "2010/Sep/13 17:03", "Thorn EMI Heating", "Thorn EMI Heating", "Orion Fanfare", "40si", "4179507", "", "1993", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "11.7", "11.7", "", "", "69.0", "59.0", "", "43.0", "", "3", "", "", "0", "1", "1", "60", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1145, "brand_name": "Thorn EMI Heating", "model_name": "Orion Fanfare", "model_qualifier": "50si", "winter_efficiency_pct": 69.0, "summer_efficiency_pct": 59.0, "comparative_hot_water_efficiency_pct": 43.0, "output_kw_max": 14.7, "final_year_of_manufacture": 1993, "raw": ["001145", "000005", "0", "2010/Sep/13 17:03", "Thorn EMI Heating", "Thorn EMI Heating", "Orion Fanfare", "50si", "4179508", "", "1993", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "14.7", "14.7", "", "", "69.0", "59.0", "", "43.0", "", "3", "", "", "0", "1", "1", "60", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1146, "brand_name": "Thorn EMI Heating", "model_name": "Orion Fanfare", "model_qualifier": "60si", "winter_efficiency_pct": 69.0, "summer_efficiency_pct": 59.0, "comparative_hot_water_efficiency_pct": 43.0, "output_kw_max": 17.6, "final_year_of_manufacture": null, "raw": ["001146", "000005", "0", "2010/Sep/13 17:03", "Thorn EMI Heating", "Thorn EMI Heating", "Orion Fanfare", "60si", "4179509", "", "obsolete", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "17.6", "17.6", "", "", "69.0", "59.0", "", "43.0", "", "3", "", "", "0", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1147, "brand_name": "Thorn EMI Heating", "model_name": "Thorn Harcal Havana", "model_qualifier": "", "winter_efficiency_pct": 65.0, "summer_efficiency_pct": 53.0, "comparative_hot_water_efficiency_pct": 38.9, "output_kw_max": 10.9, "final_year_of_manufacture": null, "raw": ["001147", "000005", "0", "2010/Sep/13 17:03", "Thorn EMI Heating", "Thorn EMI Heating", "Thorn Harcal Havana", "", "", "", "obsolete", "4", "0", "0", "1", "0", "", "", "1", "1", "1", "10.9", "10.9", "", "", "65.0", "53.0", "", "38.9", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1148, "brand_name": "Thorn EMI Heating", "model_name": "Thorn Harcal", "model_qualifier": "200", "winter_efficiency_pct": 65.0, "summer_efficiency_pct": 53.0, "comparative_hot_water_efficiency_pct": 38.9, "output_kw_max": 10.9, "final_year_of_manufacture": null, "raw": ["001148", "000005", "0", "2010/Sep/13 17:03", "Thorn EMI Heating", "Thorn EMI Heating", "Thorn Harcal", "200", "", "", "obsolete", "4", "0", "0", "1", "0", "", "", "1", "1", "1", "10.9", "10.9", "", "", "65.0", "53.0", "", "38.9", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1150, "brand_name": "Thorn EMI Heating", "model_name": "Thorn Janitor", "model_qualifier": "ODY-3", "winter_efficiency_pct": 65.0, "summer_efficiency_pct": 53.0, "comparative_hot_water_efficiency_pct": 38.9, "output_kw_max": 22.0, "final_year_of_manufacture": null, "raw": ["001150", "000005", "0", "2010/Sep/13 17:03", "Thorn EMI Heating", "Thorn EMI Heating", "Thorn Janitor", "ODY-3", "", "", "obsolete", "4", "0", "0", "1", "0", "", "", "1", "2", "2", "17.6", "22.0", "", "", "65.0", "53.0", "", "38.9", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1151, "brand_name": "Thorn EMI Heating", "model_name": "Thorn Janitor", "model_qualifier": "OV-45", "winter_efficiency_pct": 65.0, "summer_efficiency_pct": 53.0, "comparative_hot_water_efficiency_pct": 38.9, "output_kw_max": 13.2, "final_year_of_manufacture": null, "raw": ["001151", "000005", "0", "2010/Sep/13 17:03", "Thorn EMI Heating", "Thorn EMI Heating", "Thorn Janitor", "OV-45", "", "", "obsolete", "4", "0", "0", "1", "0", "", "", "1", "1", "1", "13.2", "13.2", "", "", "65.0", "53.0", "", "38.9", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1152, "brand_name": "Thorn EMI Heating", "model_name": "Harcal", "model_qualifier": "260", "winter_efficiency_pct": 65.0, "summer_efficiency_pct": 53.0, "comparative_hot_water_efficiency_pct": 38.9, "output_kw_max": 13.2, "final_year_of_manufacture": null, "raw": ["001152", "000005", "0", "2010/Sep/13 17:03", "Thorn EMI Heating", "Thorn EMI Heating", "Harcal", "260", "", "", "obsolete", "4", "0", "0", "1", "0", "", "", "1", "1", "1", "13.2", "13.2", "", "", "65.0", "53.0", "", "38.9", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1159, "brand_name": "Trianco", "model_name": "Trianco", "model_qualifier": "firelite", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": null, "final_year_of_manufacture": null, "raw": ["001159", "000062", "0", "2010/Sep/13 17:03", "Trianco Redfyre", "Trianco", "Trianco", "firelite", "3789803", "", "obsolete", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "", "", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1160, "brand_name": "Trianco", "model_name": "Triancogas", "model_qualifier": "25/40", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": null, "final_year_of_manufacture": null, "raw": ["001160", "000062", "0", "2010/Sep/13 17:03", "Trianco Redfyre", "Trianco", "Triancogas", "25/40", "4489801", "", "obsolete", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "", "", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1161, "brand_name": "Trianco", "model_name": "Triancogas", "model_qualifier": "35/50", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": null, "final_year_of_manufacture": null, "raw": ["001161", "000062", "0", "2010/Sep/13 17:03", "Trianco Redfyre", "Trianco", "Triancogas", "35/50", "4489802", "", "obsolete", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "", "", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1162, "brand_name": "Trianco", "model_name": "Tristar", "model_qualifier": "35f", "winter_efficiency_pct": 73.0, "summer_efficiency_pct": 63.0, "comparative_hot_water_efficiency_pct": 45.9, "output_kw_max": 10.3, "final_year_of_manufacture": null, "raw": ["001162", "000062", "0", "2015/Jul/21 14:15", "Trianco Redfyre", "Trianco", "Tristar", "35f", "4189844", "", "obsolete", "1", "0", "0", "1", "0", "", "", "1", "2", "2", "10.3", "10.3", "", "", "73.0", "63.0", "", "45.9", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1163, "brand_name": "Trianco", "model_name": "Tristar", "model_qualifier": "45f", "winter_efficiency_pct": 73.0, "summer_efficiency_pct": 63.0, "comparative_hot_water_efficiency_pct": 45.9, "output_kw_max": 13.19, "final_year_of_manufacture": null, "raw": ["001163", "000062", "0", "2015/Jul/21 14:15", "Trianco Redfyre", "Trianco", "Tristar", "45f", "4189845", "", "obsolete", "1", "0", "0", "1", "0", "", "", "1", "2", "2", "13.19", "13.19", "", "", "73.0", "63.0", "", "45.9", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1164, "brand_name": "Trianco", "model_name": "Tristar", "model_qualifier": "52f", "winter_efficiency_pct": 73.0, "summer_efficiency_pct": 63.0, "comparative_hot_water_efficiency_pct": 45.9, "output_kw_max": 15.24, "final_year_of_manufacture": null, "raw": ["001164", "000062", "0", "2015/Jul/21 14:15", "Trianco Redfyre", "Trianco", "Tristar", "52f", "4189846", "", "obsolete", "1", "0", "0", "1", "0", "", "", "1", "2", "2", "15.24", "15.24", "", "", "73.0", "63.0", "", "45.9", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1165, "brand_name": "Trianco", "model_name": "Tristar", "model_qualifier": "60f", "winter_efficiency_pct": 73.0, "summer_efficiency_pct": 63.0, "comparative_hot_water_efficiency_pct": 45.9, "output_kw_max": 17.58, "final_year_of_manufacture": null, "raw": ["001165", "000062", "0", "2015/Jul/21 14:15", "Trianco Redfyre", "Trianco", "Tristar", "60f", "4189847", "", "obsolete", "1", "0", "0", "1", "0", "", "", "1", "2", "2", "17.58", "17.58", "", "", "73.0", "63.0", "", "45.9", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1166, "brand_name": "Trianco", "model_name": "Tristar", "model_qualifier": "80f", "winter_efficiency_pct": 73.0, "summer_efficiency_pct": 63.0, "comparative_hot_water_efficiency_pct": 45.9, "output_kw_max": 23.44, "final_year_of_manufacture": null, "raw": ["001166", "000062", "0", "2015/Jul/21 14:15", "Trianco Redfyre", "Trianco", "Tristar", "80f", "4189848", "", "obsolete", "1", "0", "0", "1", "0", "", "", "1", "2", "2", "23.44", "23.44", "", "", "73.0", "63.0", "", "45.9", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1167, "brand_name": "Trianco", "model_name": "Valor", "model_qualifier": "Homeflame Super", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": null, "final_year_of_manufacture": null, "raw": ["001167", "000062", "0", "2010/Sep/13 17:03", "Trianco Redfyre", "Trianco", "Valor", "Homeflame Super", "3789801", "", "obsolete", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "", "", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1168, "brand_name": "Trianco", "model_name": "Valor", "model_qualifier": "Majestic", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": null, "final_year_of_manufacture": null, "raw": ["001168", "000062", "0", "2010/Sep/13 17:03", "Trianco Redfyre", "Trianco", "Valor", "Majestic", "3789802", "", "obsolete", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "", "", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1169, "brand_name": "Trianco", "model_name": "Wm", "model_qualifier": "20/30rs", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 8.8, "final_year_of_manufacture": null, "raw": ["001169", "000062", "0", "2010/Sep/13 17:03", "Trianco Redfyre", "Trianco", "Wm", "20/30rs", "4189835", "", "obsolete", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "8.8", "8.8", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1170, "brand_name": "Trianco", "model_name": "Wm", "model_qualifier": "20/35f", "winter_efficiency_pct": 73.0, "summer_efficiency_pct": 63.0, "comparative_hot_water_efficiency_pct": 45.9, "output_kw_max": 10.25, "final_year_of_manufacture": 1990, "raw": ["001170", "000062", "0", "2015/Jul/21 14:15", "Trianco Redfyre", "Trianco", "Wm", "20/35f", "4189840", "", "1990", "1", "0", "0", "1", "0", "", "", "1", "2", "2", "10.25", "10.25", "", "", "73.0", "63.0", "", "45.9", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1171, "brand_name": "Trianco", "model_name": "Wm", "model_qualifier": "25/45rs", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 13.2, "final_year_of_manufacture": null, "raw": ["001171", "000062", "0", "2010/Sep/13 17:03", "Trianco Redfyre", "Trianco", "Wm", "25/45rs", "4189829", "", "obsolete", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "13.2", "13.2", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1172, "brand_name": "Trianco", "model_name": "Wm", "model_qualifier": "30/40rs", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 11.7, "final_year_of_manufacture": null, "raw": ["001172", "000062", "0", "2010/Sep/13 17:03", "Trianco Redfyre", "Trianco", "Wm", "30/40rs", "4189836", "", "obsolete", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "11.7", "11.7", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1173, "brand_name": "Trianco", "model_name": "Wm", "model_qualifier": "30/50f", "winter_efficiency_pct": 73.0, "summer_efficiency_pct": 63.0, "comparative_hot_water_efficiency_pct": 45.9, "output_kw_max": 14.65, "final_year_of_manufacture": 1992, "raw": ["001173", "000062", "0", "2015/Jul/21 14:15", "Trianco Redfyre", "Trianco", "Wm", "30/50f", "4189832", "", "1992", "1", "0", "0", "1", "0", "", "", "1", "2", "2", "14.65", "14.65", "", "", "73.0", "63.0", "", "45.9", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1174, "brand_name": "Trianco", "model_name": "Wm", "model_qualifier": "35/50f", "winter_efficiency_pct": 73.0, "summer_efficiency_pct": 63.0, "comparative_hot_water_efficiency_pct": 45.9, "output_kw_max": 14.65, "final_year_of_manufacture": 1992, "raw": ["001174", "000062", "0", "2015/Jul/21 14:15", "Trianco Redfyre", "Trianco", "Wm", "35/50f", "4189841", "", "1992", "1", "0", "0", "1", "0", "", "", "1", "2", "2", "14.65", "14.65", "", "", "73.0", "63.0", "", "45.9", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1175, "brand_name": "Trianco", "model_name": "Wm", "model_qualifier": "40/50rs", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 14.7, "final_year_of_manufacture": null, "raw": ["001175", "000062", "0", "2010/Sep/13 17:03", "Trianco Redfyre", "Trianco", "Wm", "40/50rs", "4189837", "", "obsolete", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "14.7", "14.7", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1176, "brand_name": "Trianco", "model_name": "Wm", "model_qualifier": "45/60rs", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 17.6, "final_year_of_manufacture": null, "raw": ["001176", "000062", "0", "2010/Sep/13 17:03", "Trianco Redfyre", "Trianco", "Wm", "45/60rs", "4189830", "", "obsolete", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "17.6", "17.6", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1177, "brand_name": "Trianco", "model_name": "Wm", "model_qualifier": "50/60rs", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 17.6, "final_year_of_manufacture": null, "raw": ["001177", "000062", "0", "2010/Sep/13 17:03", "Trianco Redfyre", "Trianco", "Wm", "50/60rs", "4189838", "", "obsolete", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "17.6", "17.6", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1178, "brand_name": "Trianco", "model_name": "Wm", "model_qualifier": "50/65f", "winter_efficiency_pct": 73.0, "summer_efficiency_pct": 63.0, "comparative_hot_water_efficiency_pct": 45.9, "output_kw_max": 19.05, "final_year_of_manufacture": 1992, "raw": ["001178", "000062", "0", "2015/Jul/21 14:15", "Trianco Redfyre", "Trianco", "Wm", "50/65f", "4189833", "", "1992", "1", "0", "0", "1", "0", "", "", "1", "2", "2", "19.05", "19.05", "", "", "73.0", "63.0", "", "45.9", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1179, "brand_name": "Trianco", "model_name": "Wm", "model_qualifier": "60/75rs", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 22.0, "final_year_of_manufacture": null, "raw": ["001179", "000062", "0", "2010/Sep/13 17:03", "Trianco Redfyre", "Trianco", "Wm", "60/75rs", "4189831", "", "obsolete", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "22", "22", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1180, "brand_name": "Trianco", "model_name": "Wm", "model_qualifier": "65/80f", "winter_efficiency_pct": 73.0, "summer_efficiency_pct": 63.0, "comparative_hot_water_efficiency_pct": 45.9, "output_kw_max": 23.15, "final_year_of_manufacture": 1992, "raw": ["001180", "000062", "0", "2015/Jul/21 14:15", "Trianco Redfyre", "Trianco", "Wm", "65/80f", "4189834", "", "1992", "1", "0", "0", "1", "0", "", "", "1", "2", "2", "23.15", "23.15", "", "", "73.0", "63.0", "", "45.9", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1181, "brand_name": "Trianco", "model_name": "TRO", "model_qualifier": "12/14 Mk3 CF", "winter_efficiency_pct": 70.0, "summer_efficiency_pct": 58.0, "comparative_hot_water_efficiency_pct": 42.6, "output_kw_max": 14.0, "final_year_of_manufacture": null, "raw": ["001181", "000062", "0", "2010/Sep/13 17:03", "Trianco Redfyre", "Trianco", "TRO", "12/14 Mk3 CF", "", "", "obsolete", "4", "0", "0", "1", "0", "", "", "1", "2", "2", "12", "14", "", "", "70.0", "58.0", "", "42.6", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1182, "brand_name": "Trianco", "model_name": "TRO", "model_qualifier": "15/19 Mk3 CF", "winter_efficiency_pct": 70.0, "summer_efficiency_pct": 58.0, "comparative_hot_water_efficiency_pct": 42.6, "output_kw_max": 19.0, "final_year_of_manufacture": null, "raw": ["001182", "000062", "0", "2010/Sep/13 17:03", "Trianco Redfyre", "Trianco", "TRO", "15/19 Mk3 CF", "", "", "obsolete", "4", "0", "0", "1", "0", "", "", "1", "2", "2", "15", "19", "", "", "70.0", "58.0", "", "42.6", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1183, "brand_name": "Trianco", "model_name": "TRO", "model_qualifier": "20/25 Mk3 CF", "winter_efficiency_pct": 70.0, "summer_efficiency_pct": 58.0, "comparative_hot_water_efficiency_pct": 42.6, "output_kw_max": 25.0, "final_year_of_manufacture": null, "raw": ["001183", "000062", "0", "2010/Sep/13 17:03", "Trianco Redfyre", "Trianco", "TRO", "20/25 Mk3 CF", "", "", "obsolete", "4", "0", "0", "1", "0", "", "", "1", "2", "2", "20", "25", "", "", "70.0", "58.0", "", "42.6", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1184, "brand_name": "Trianco", "model_name": "TRO", "model_qualifier": "28/32 Mk3 CF", "winter_efficiency_pct": 70.0, "summer_efficiency_pct": 58.0, "comparative_hot_water_efficiency_pct": 42.6, "output_kw_max": 32.0, "final_year_of_manufacture": null, "raw": ["001184", "000062", "0", "2010/Sep/13 17:03", "Trianco Redfyre", "Trianco", "TRO", "28/32 Mk3 CF", "", "", "obsolete", "4", "0", "0", "1", "0", "", "", "1", "2", "2", "28", "32", "", "", "70.0", "58.0", "", "42.6", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1185, "brand_name": "Trianco", "model_name": "TRO", "model_qualifier": "37/45 Mk3 CF", "winter_efficiency_pct": 70.0, "summer_efficiency_pct": 58.0, "comparative_hot_water_efficiency_pct": 42.6, "output_kw_max": 45.0, "final_year_of_manufacture": null, "raw": ["001185", "000062", "0", "2010/Sep/13 17:03", "Trianco Redfyre", "Trianco", "TRO", "37/45 Mk3 CF", "", "", "obsolete", "4", "0", "0", "1", "0", "", "", "1", "2", "2", "37", "45", "", "", "70.0", "58.0", "", "42.6", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1187, "brand_name": "Trianco", "model_name": "TRO", "model_qualifier": "12/14 BF Room Sealed", "winter_efficiency_pct": 70.0, "summer_efficiency_pct": 58.0, "comparative_hot_water_efficiency_pct": 42.6, "output_kw_max": 14.0, "final_year_of_manufacture": null, "raw": ["001187", "000062", "0", "2010/Sep/13 17:03", "Trianco Redfyre", "Trianco", "TRO", "12/14 BF Room Sealed", "", "", "obsolete", "4", "0", "0", "1", "0", "", "", "1", "2", "2", "12", "14", "", "", "70.0", "58.0", "", "42.6", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1188, "brand_name": "Trianco", "model_name": "TRO", "model_qualifier": "15/19 BF Room Sealed", "winter_efficiency_pct": 70.0, "summer_efficiency_pct": 58.0, "comparative_hot_water_efficiency_pct": 42.6, "output_kw_max": 19.0, "final_year_of_manufacture": null, "raw": ["001188", "000062", "0", "2010/Sep/13 17:03", "Trianco Redfyre", "Trianco", "TRO", "15/19 BF Room Sealed", "", "", "obsolete", "4", "0", "0", "1", "0", "", "", "1", "2", "2", "15", "19", "", "", "70.0", "58.0", "", "42.6", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1190, "brand_name": "Trianco", "model_name": "TRO", "model_qualifier": "28/32 BF Room Sealed", "winter_efficiency_pct": 70.0, "summer_efficiency_pct": 58.0, "comparative_hot_water_efficiency_pct": 42.6, "output_kw_max": 32.0, "final_year_of_manufacture": null, "raw": ["001190", "000062", "0", "2010/Sep/13 17:03", "Trianco Redfyre", "Trianco", "TRO", "28/32 BF Room Sealed", "", "", "obsolete", "4", "0", "0", "1", "0", "", "", "1", "2", "2", "28", "32", "", "", "70.0", "58.0", "", "42.6", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1191, "brand_name": "Trianco", "model_name": "TRO", "model_qualifier": "80 Combi WM C.F.", "winter_efficiency_pct": 71.0, "summer_efficiency_pct": 62.0, "comparative_hot_water_efficiency_pct": 43.2, "output_kw_max": 23.0, "final_year_of_manufacture": null, "raw": ["001191", "000062", "0", "2010/Sep/13 17:03", "Trianco Redfyre", "Trianco", "TRO", "80 Combi WM C.F.", "", "", "obsolete", "4", "0", "0", "2", "0", "", "", "1", "2", "2", "23", "23", "", "", "71.0", "62.0", "", "43.2", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1192, "brand_name": "Trianco", "model_name": "TRO", "model_qualifier": "110 Combi FS C.F.", "winter_efficiency_pct": 71.0, "summer_efficiency_pct": 62.0, "comparative_hot_water_efficiency_pct": 43.2, "output_kw_max": 32.0, "final_year_of_manufacture": null, "raw": ["001192", "000062", "0", "2010/Sep/13 17:03", "Trianco Redfyre", "Trianco", "TRO", "110 Combi FS C.F.", "", "", "obsolete", "4", "0", "0", "2", "0", "", "", "1", "2", "2", "32", "32", "", "", "71.0", "62.0", "", "43.2", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1193, "brand_name": "Trianco", "model_name": "Centrajet", "model_qualifier": "13/17 WM", "winter_efficiency_pct": 70.0, "summer_efficiency_pct": 58.0, "comparative_hot_water_efficiency_pct": 42.6, "output_kw_max": 17.0, "final_year_of_manufacture": null, "raw": ["001193", "000062", "0", "2010/Sep/13 17:03", "Trianco Redfyre", "Trianco", "Centrajet", "13/17 WM", "", "", "obsolete", "4", "0", "0", "1", "0", "", "", "1", "2", "2", "13", "17", "", "", "70.0", "58.0", "", "42.6", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1195, "brand_name": "Trianco", "model_name": "TSB", "model_qualifier": "12/14 BF Sealed System", "winter_efficiency_pct": 70.0, "summer_efficiency_pct": 58.0, "comparative_hot_water_efficiency_pct": 42.6, "output_kw_max": 14.0, "final_year_of_manufacture": null, "raw": ["001195", "000062", "0", "2010/Sep/13 17:03", "Trianco Redfyre", "Trianco", "TSB", "12/14 BF Sealed System", "", "", "obsolete", "4", "0", "0", "1", "0", "", "", "1", "2", "2", "12", "14", "", "", "70.0", "58.0", "", "42.6", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1197, "brand_name": "Trianco", "model_name": "TSB", "model_qualifier": "15/19 BF Sealed System", "winter_efficiency_pct": 70.0, "summer_efficiency_pct": 58.0, "comparative_hot_water_efficiency_pct": 42.6, "output_kw_max": 19.0, "final_year_of_manufacture": null, "raw": ["001197", "000062", "0", "2010/Sep/13 17:03", "Trianco Redfyre", "Trianco", "TSB", "15/19 BF Sealed System", "", "", "obsolete", "4", "0", "0", "1", "0", "", "", "1", "2", "2", "15", "19", "", "", "70.0", "58.0", "", "42.6", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1199, "brand_name": "Trianco", "model_name": "TSB", "model_qualifier": "20/25 BF Sealed System", "winter_efficiency_pct": 70.0, "summer_efficiency_pct": 58.0, "comparative_hot_water_efficiency_pct": 42.6, "output_kw_max": 25.0, "final_year_of_manufacture": null, "raw": ["001199", "000062", "0", "2010/Sep/13 17:03", "Trianco Redfyre", "Trianco", "TSB", "20/25 BF Sealed System", "", "", "obsolete", "4", "0", "0", "1", "0", "", "", "1", "2", "2", "20", "25", "", "", "70.0", "58.0", "", "42.6", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1201, "brand_name": "Trianco", "model_name": "TSV", "model_qualifier": "45", "winter_efficiency_pct": 65.0, "summer_efficiency_pct": 53.0, "comparative_hot_water_efficiency_pct": 38.9, "output_kw_max": 12.3, "final_year_of_manufacture": null, "raw": ["001201", "000062", "0", "2010/Sep/13 17:03", "Trianco Redfyre", "Trianco", "TSV", "45", "", "", "obsolete", "4", "0", "0", "1", "0", "", "", "1", "1", "1", "12.3", "12.3", "", "", "65.0", "53.0", "", "38.9", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1202, "brand_name": "Trianco", "model_name": "TSV", "model_qualifier": "60", "winter_efficiency_pct": 65.0, "summer_efficiency_pct": 53.0, "comparative_hot_water_efficiency_pct": 38.9, "output_kw_max": 17.6, "final_year_of_manufacture": null, "raw": ["001202", "000062", "0", "2010/Sep/13 17:03", "Trianco Redfyre", "Trianco", "TSV", "60", "", "", "obsolete", "4", "0", "0", "1", "0", "", "", "1", "1", "1", "17.6", "17.6", "", "", "65.0", "53.0", "", "38.9", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1203, "brand_name": "Trianco", "model_name": "TSV", "model_qualifier": "80", "winter_efficiency_pct": 65.0, "summer_efficiency_pct": 53.0, "comparative_hot_water_efficiency_pct": 38.9, "output_kw_max": 23.4, "final_year_of_manufacture": null, "raw": ["001203", "000062", "0", "2010/Sep/13 17:03", "Trianco Redfyre", "Trianco", "TSV", "80", "", "", "obsolete", "4", "0", "0", "1", "0", "", "", "1", "1", "1", "23.4", "23.4", "", "", "65.0", "53.0", "", "38.9", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1204, "brand_name": "Trianco", "model_name": "TSO", "model_qualifier": "15/17", "winter_efficiency_pct": 65.0, "summer_efficiency_pct": 53.0, "comparative_hot_water_efficiency_pct": 38.9, "output_kw_max": 17.0, "final_year_of_manufacture": null, "raw": ["001204", "000062", "0", "2010/Sep/13 17:03", "Trianco Redfyre", "Trianco", "TSO", "15/17", "", "", "obsolete", "4", "0", "0", "1", "0", "", "", "1", "2", "2", "17", "17", "", "", "65.0", "53.0", "", "38.9", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1205, "brand_name": "Trianco", "model_name": "TSO", "model_qualifier": "65/85", "winter_efficiency_pct": 65.0, "summer_efficiency_pct": 53.0, "comparative_hot_water_efficiency_pct": 38.9, "output_kw_max": 24.9, "final_year_of_manufacture": null, "raw": ["001205", "000062", "0", "2010/Sep/13 17:03", "Trianco Redfyre", "Trianco", "TSO", "65/85", "", "", "obsolete", "4", "0", "0", "1", "0", "", "", "1", "2", "2", "24.9", "24.9", "", "", "65.0", "53.0", "", "38.9", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1206, "brand_name": "Trianco", "model_name": "TSO", "model_qualifier": "95/110", "winter_efficiency_pct": 65.0, "summer_efficiency_pct": 53.0, "comparative_hot_water_efficiency_pct": 38.9, "output_kw_max": 32.2, "final_year_of_manufacture": null, "raw": ["001206", "000062", "0", "2010/Sep/13 17:03", "Trianco Redfyre", "Trianco", "TSO", "95/110", "", "", "obsolete", "4", "0", "0", "1", "0", "", "", "1", "2", "2", "32.2", "32.2", "", "", "65.0", "53.0", "", "38.9", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1223, "brand_name": "Alde", "model_name": "Slimline", "model_qualifier": "2927", "winter_efficiency_pct": 71.0, "summer_efficiency_pct": 62.0, "comparative_hot_water_efficiency_pct": 43.2, "output_kw_max": 5.8, "final_year_of_manufacture": 1991, "raw": ["001223", "000067", "0", "2010/Sep/13 17:03", "Alde", "Alde", "Slimline", "2927", "4104801", "1985", "1991", "1", "1", "0", "2", "0", "", "", "1", "2", "2", "5.8", "5.8", "", "", "71.0", "62.0", "", "43.2", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1242, "brand_name": "Glotec", "model_name": "Glotec", "model_qualifier": "gt80", "winter_efficiency_pct": 91.0, "summer_efficiency_pct": 74.0, "comparative_hot_water_efficiency_pct": 53.7, "output_kw_max": 21.9, "final_year_of_manufacture": 1991, "raw": ["001242", "000073", "0", "2010/Sep/13 17:03", "Glotec", "Glotec", "Glotec", "gt80", "4130501", "", "1991", "1", "0", "0", "1", "0", "", "", "2", "2", "2", "21.9", "21.9", "", "", "91.0", "74.0", "", "53.7", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0001", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1243, "brand_name": "Glow-worm", "model_name": "105-120B", "model_qualifier": "105-120B", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 35.2, "final_year_of_manufacture": 1985, "raw": ["001243", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "105-120B", "105-120B", "4131556", "", "1985", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "35.2", "35.2", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1244, "brand_name": "Glow-worm", "model_name": "105-120", "model_qualifier": "105-120", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 35.2, "final_year_of_manufacture": 1985, "raw": ["001244", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "105-120", "105-120", "4131555", "", "1985", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "35.2", "35.2", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1245, "brand_name": "Glow-worm", "model_name": "45-60", "model_qualifier": "45-60", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 17.6, "final_year_of_manufacture": 1985, "raw": ["001245", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "45-60", "45-60", "4131549", "", "1985", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "17.6", "17.6", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1246, "brand_name": "Glow-worm", "model_name": "45-60B", "model_qualifier": "45-60B", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 17.6, "final_year_of_manufacture": 1985, "raw": ["001246", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "45-60B", "45-60B", "4131550", "", "1985", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "17.6", "17.6", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1248, "brand_name": "Glow-worm", "model_name": "65-80", "model_qualifier": "65-80", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 23.5, "final_year_of_manufacture": 1985, "raw": ["001248", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "65-80", "65-80", "4131551", "", "1985", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "23.5", "23.5", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1250, "brand_name": "Glow-worm", "model_name": "65-80B", "model_qualifier": "65-80B", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 23.5, "final_year_of_manufacture": 1985, "raw": ["001250", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "65-80B", "65-80B", "4131558", "", "1985", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "23.5", "23.5", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1252, "brand_name": "Glow-worm", "model_name": "85-100", "model_qualifier": "85-100", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 29.3, "final_year_of_manufacture": 1985, "raw": ["001252", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "85-100", "85-100", "4131553", "", "1985", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "29.3", "29.3", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1254, "brand_name": "Glow-worm", "model_name": "85-100B", "model_qualifier": "85-100B", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 29.3, "final_year_of_manufacture": 1985, "raw": ["001254", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "85-100B", "85-100B", "4131560", "", "1985", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "29.3", "29.3", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1255, "brand_name": "Glow-worm", "model_name": "Camelot", "model_qualifier": "240/6", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": null, "final_year_of_manufacture": 1986, "raw": ["001255", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Camelot", "240/6", "3731407", "", "1986", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "", "", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1256, "brand_name": "Glow-worm", "model_name": "Capricorn", "model_qualifier": "240/6", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": null, "final_year_of_manufacture": 1986, "raw": ["001256", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Capricorn", "240/6", "3731406", "", "1986", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "", "", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1257, "brand_name": "Glow-worm", "model_name": "Capricorn", "model_qualifier": "246", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": null, "final_year_of_manufacture": 1982, "raw": ["001257", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Capricorn", "246", "4431518", "", "1982", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "", "", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1259, "brand_name": "Glow-worm", "model_name": "Economy Plus", "model_qualifier": "100f", "winter_efficiency_pct": 73.0, "summer_efficiency_pct": 63.0, "comparative_hot_water_efficiency_pct": 45.9, "output_kw_max": 29.3, "final_year_of_manufacture": null, "raw": ["001259", "000207", "0", "2015/Jul/21 14:15", "Glow-worm", "Glow-worm", "Economy Plus", "100f", "", "", "obsolete", "1", "0", "0", "1", "0", "", "", "1", "2", "2", "29.3", "29.3", "", "", "73.0", "63.0", "", "45.9", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1277, "brand_name": "Glow-worm", "model_name": "Fuelsaver", "model_qualifier": "100F", "winter_efficiency_pct": 73.0, "summer_efficiency_pct": 63.0, "comparative_hot_water_efficiency_pct": 45.9, "output_kw_max": 29.3, "final_year_of_manufacture": null, "raw": ["001277", "000207", "0", "2015/Jul/21 14:15", "Glow-worm", "Glow-worm", "Fuelsaver", "100F", "4131332", "", "obsolete", "1", "0", "0", "1", "0", "", "", "1", "2", "2", "29.3", "29.3", "", "", "73.0", "63.0", "", "45.9", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1278, "brand_name": "Glow-worm", "model_name": "Fuelsaver", "model_qualifier": "25-30", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 8.8, "final_year_of_manufacture": 1984, "raw": ["001278", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Fuelsaver", "25-30", "4131580", "", "1984", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "8.8", "8.8", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1279, "brand_name": "Glow-worm", "model_name": "Fuelsaver", "model_qualifier": "25-30B", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 8.79, "final_year_of_manufacture": 1984, "raw": ["001279", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Fuelsaver", "25-30B", "4131579", "", "1984", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "8.79", "8.79", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1280, "brand_name": "Glow-worm", "model_name": "Fuelsaver", "model_qualifier": "30-40", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 11.7, "final_year_of_manufacture": 1984, "raw": ["001280", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Fuelsaver", "30-40", "4131582", "", "1984", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "11.7", "11.7", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1281, "brand_name": "Glow-worm", "model_name": "Fuelsaver", "model_qualifier": "30-40B", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 11.72, "final_year_of_manufacture": 1983, "raw": ["001281", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Fuelsaver", "30-40B", "4131581", "", "1983", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "11.72", "11.72", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1282, "brand_name": "Glow-worm", "model_name": "Fuelsaver", "model_qualifier": "30bmk2", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 8.79, "final_year_of_manufacture": 1988, "raw": ["001282", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Fuelsaver", "30bmk2", "4131304", "", "1988", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "8.79", "8.79", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1283, "brand_name": "Glow-worm", "model_name": "Fuelsaver", "model_qualifier": "30brmk2", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 8.79, "final_year_of_manufacture": 1991, "raw": ["001283", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Fuelsaver", "30brmk2", "4131372", "", "1991", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "8.79", "8.79", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1284, "brand_name": "Glow-worm", "model_name": "Fuelsaver", "model_qualifier": "30mk2", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 8.79, "final_year_of_manufacture": 1988, "raw": ["001284", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Fuelsaver", "30mk2", "4131318", "", "1988", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "8.79", "8.79", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1285, "brand_name": "Glow-worm", "model_name": "Fuelsaver", "model_qualifier": "35f", "winter_efficiency_pct": 69.0, "summer_efficiency_pct": 59.0, "comparative_hot_water_efficiency_pct": 43.0, "output_kw_max": 10.26, "final_year_of_manufacture": 1991, "raw": ["001285", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Fuelsaver", "35f", "4131309", "", "1991", "1", "0", "0", "1", "0", "", "", "1", "2", "2", "10.26", "10.26", "", "", "69.0", "59.0", "", "43.0", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1286, "brand_name": "Glow-worm", "model_name": "Fuelsaver", "model_qualifier": "40-50", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 14.7, "final_year_of_manufacture": 1984, "raw": ["001286", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Fuelsaver", "40-50", "4131584", "", "1984", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "14.7", "14.7", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1287, "brand_name": "Glow-worm", "model_name": "Fuelsaver", "model_qualifier": "40-50b", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 14.65, "final_year_of_manufacture": 1983, "raw": ["001287", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Fuelsaver", "40-50b", "4131583", "", "1983", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "14.65", "14.65", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1288, "brand_name": "Glow-worm", "model_name": "Fuelsaver", "model_qualifier": "40bmk2", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 11.72, "final_year_of_manufacture": 1988, "raw": ["001288", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Fuelsaver", "40bmk2", "4131596", "", "1988", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "11.72", "11.72", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1289, "brand_name": "Glow-worm", "model_name": "Fuelsaver", "model_qualifier": "40brmk2", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 11.72, "final_year_of_manufacture": 1991, "raw": ["001289", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Fuelsaver", "40brmk2", "4131373", "", "1991", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "11.72", "11.72", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1290, "brand_name": "Glow-worm", "model_name": "Fuelsaver", "model_qualifier": "40mk2", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 11.7, "final_year_of_manufacture": 1988, "raw": ["001290", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Fuelsaver", "40mk2", "4131319", "", "1988", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "11.7", "11.7", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1291, "brand_name": "Glow-worm", "model_name": "Fuelsaver", "model_qualifier": "45f", "winter_efficiency_pct": 69.0, "summer_efficiency_pct": 59.0, "comparative_hot_water_efficiency_pct": 43.0, "output_kw_max": 13.19, "final_year_of_manufacture": 1991, "raw": ["001291", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Fuelsaver", "45f", "4131335", "", "1991", "1", "0", "0", "1", "0", "", "", "1", "2", "2", "13.19", "13.19", "", "", "69.0", "59.0", "", "43.0", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1292, "brand_name": "Glow-worm", "model_name": "Fuelsaver", "model_qualifier": "50bmk2", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 14.65, "final_year_of_manufacture": 1988, "raw": ["001292", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Fuelsaver", "50bmk2", "4131595", "", "1988", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "14.65", "14.65", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1293, "brand_name": "Glow-worm", "model_name": "Fuelsaver", "model_qualifier": "50brmk2", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 14.65, "final_year_of_manufacture": 1991, "raw": ["001293", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Fuelsaver", "50brmk2", "4131374", "", "1991", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "14.65", "14.65", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1294, "brand_name": "Glow-worm", "model_name": "Fuelsaver", "model_qualifier": "50mk2", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 14.65, "final_year_of_manufacture": 1988, "raw": ["001294", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Fuelsaver", "50mk2", "4131320", "", "1988", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "14.65", "14.65", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1295, "brand_name": "Glow-worm", "model_name": "Fuelsaver", "model_qualifier": "55-60b", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 17.6, "final_year_of_manufacture": 1984, "raw": ["001295", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Fuelsaver", "55-60b", "4131585", "", "1984", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "17.6", "17.6", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1296, "brand_name": "Glow-worm", "model_name": "Fuelsaver", "model_qualifier": "55f", "winter_efficiency_pct": 69.0, "summer_efficiency_pct": 59.0, "comparative_hot_water_efficiency_pct": 43.0, "output_kw_max": 16.12, "final_year_of_manufacture": 1991, "raw": ["001296", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Fuelsaver", "55f", "4131306", "", "1991", "1", "0", "0", "1", "0", "", "", "1", "2", "2", "16.12", "16.12", "", "", "69.0", "59.0", "", "43.0", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1297, "brand_name": "Glow-worm", "model_name": "Fuelsaver", "model_qualifier": "60-70b", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 20.5, "final_year_of_manufacture": 1984, "raw": ["001297", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Fuelsaver", "60-70b", "4131587", "", "1984", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "20.5", "20.5", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1298, "brand_name": "Glow-worm", "model_name": "Fuelsaver", "model_qualifier": "60bmk2", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 17.58, "final_year_of_manufacture": 1988, "raw": ["001298", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Fuelsaver", "60bmk2", "4131310", "", "1988", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "17.58", "17.58", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1299, "brand_name": "Glow-worm", "model_name": "Fuelsaver", "model_qualifier": "60brmk2", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 17.59, "final_year_of_manufacture": 1991, "raw": ["001299", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Fuelsaver", "60brmk2", "4131375", "", "1991", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "17.59", "17.59", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1300, "brand_name": "Glow-worm", "model_name": "Fuelsaver", "model_qualifier": "60mk2", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 17.59, "final_year_of_manufacture": 1988, "raw": ["001300", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Fuelsaver", "60mk2", "4131330", "", "1988", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "17.59", "17.59", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1301, "brand_name": "Glow-worm", "model_name": "Fuelsaver", "model_qualifier": "65f", "winter_efficiency_pct": 69.0, "summer_efficiency_pct": 59.0, "comparative_hot_water_efficiency_pct": 43.0, "output_kw_max": 19.1, "final_year_of_manufacture": 1991, "raw": ["001301", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Fuelsaver", "65f", "4131333", "", "1991", "1", "0", "0", "1", "0", "", "", "1", "2", "2", "19.1", "19.1", "", "", "69.0", "59.0", "", "43.0", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1302, "brand_name": "Glow-worm", "model_name": "Fuelsaver", "model_qualifier": "75bmk2", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 22.0, "final_year_of_manufacture": 1988, "raw": ["001302", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Fuelsaver", "75bmk2", "4131311", "", "1988", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "22", "22", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1303, "brand_name": "Glow-worm", "model_name": "Fuelsaver", "model_qualifier": "75brmk2", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 22.0, "final_year_of_manufacture": 1991, "raw": ["001303", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Fuelsaver", "75brmk2", "4131376", "", "1991", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "22", "22", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1304, "brand_name": "Glow-worm", "model_name": "Fuelsaver", "model_qualifier": "75mk2", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 21.4, "final_year_of_manufacture": 1988, "raw": ["001304", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Fuelsaver", "75mk2", "4131331", "", "1988", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "21.4", "21.4", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1305, "brand_name": "Glow-worm", "model_name": "Fuelsaver", "model_qualifier": "80f", "winter_efficiency_pct": 69.0, "summer_efficiency_pct": 59.0, "comparative_hot_water_efficiency_pct": 43.0, "output_kw_max": 23.4, "final_year_of_manufacture": 1991, "raw": ["001305", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Fuelsaver", "80f", "4131323", "", "1991", "1", "0", "0", "1", "0", "", "", "1", "2", "2", "23.4", "23.4", "", "", "69.0", "59.0", "", "43.0", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1311, "brand_name": "Glow-worm", "model_name": "Galaxie", "model_qualifier": "240/6", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": null, "final_year_of_manufacture": 1986, "raw": ["001311", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Galaxie", "240/6", "3731405", "", "1986", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "", "", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1313, "brand_name": "Glow-worm", "model_name": "Galaxie", "model_qualifier": "246", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": null, "final_year_of_manufacture": 1982, "raw": ["001313", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Galaxie", "246", "4431516", "", "1982", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "", "", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1314, "brand_name": "Glow-worm", "model_name": "240", "model_qualifier": "", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": null, "final_year_of_manufacture": 1986, "raw": ["001314", "000207", "0", "2013/Jan/30 14:48", "Glow-worm", "Glow-worm", "240", "", "4431526", "", "1986", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "", "", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1315, "brand_name": "Glow-worm", "model_name": "246", "model_qualifier": "", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": null, "final_year_of_manufacture": 1986, "raw": ["001315", "000207", "0", "2013/Jan/30 14:48", "Glow-worm", "Glow-worm", "246", "", "4431525", "", "1986", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "", "", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1316, "brand_name": "Glow-worm", "model_name": "45", "model_qualifier": "", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": null, "final_year_of_manufacture": 1996, "raw": ["001316", "000207", "0", "2013/Jan/30 14:48", "Glow-worm", "Glow-worm", "45", "", "4431527", "", "1996", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "", "", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1317, "brand_name": "Glow-worm", "model_name": "45F", "model_qualifier": "", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": null, "final_year_of_manufacture": 1999, "raw": ["001317", "000207", "0", "2013/Jan/30 14:49", "Glow-worm", "Glow-worm", "45F", "", "4431529", "", "1999", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "", "", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1318, "brand_name": "Glow-worm", "model_name": "45FR", "model_qualifier": "", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": null, "final_year_of_manufacture": null, "raw": ["001318", "000207", "0", "2013/Jan/30 14:49", "Glow-worm", "Glow-worm", "45FR", "", "4431531", "", "obsolete", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "", "", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1319, "brand_name": "Glow-worm", "model_name": "56", "model_qualifier": "", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": null, "final_year_of_manufacture": 1996, "raw": ["001319", "000207", "0", "2013/Jan/30 14:49", "Glow-worm", "Glow-worm", "56", "", "4431528", "", "1996", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "", "", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1320, "brand_name": "Glow-worm", "model_name": "56F", "model_qualifier": "", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": null, "final_year_of_manufacture": 1999, "raw": ["001320", "000207", "0", "2013/Jan/30 14:49", "Glow-worm", "Glow-worm", "56F", "", "4431530", "", "1999", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "", "", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1321, "brand_name": "Glow-worm", "model_name": "56FR", "model_qualifier": "", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": null, "final_year_of_manufacture": 1999, "raw": ["001321", "000207", "0", "2013/Jan/30 14:49", "Glow-worm", "Glow-worm", "56FR", "", "4431532", "", "1999", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "", "", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1329, "brand_name": "Glow-worm", "model_name": "Hideaway", "model_qualifier": "60BL", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 17.6, "final_year_of_manufacture": 1985, "raw": ["001329", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Hideaway", "60BL", "4131312", "", "1985", "1", "1", "0", "1", "0", "", "", "1", "2", "1", "17.6", "17.6", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1330, "brand_name": "Glow-worm", "model_name": "Hideaway", "model_qualifier": "60L", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 17.6, "final_year_of_manufacture": 1995, "raw": ["001330", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Hideaway", "60L", "4131313", "", "1995", "1", "1", "0", "1", "0", "", "", "1", "1", "1", "17.6", "17.6", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1332, "brand_name": "Glow-worm", "model_name": "Hideaway", "model_qualifier": "70of", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 20.52, "final_year_of_manufacture": null, "raw": ["001332", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Hideaway", "70of", "4131382", "1984", "obsolete", "1", "1", "0", "1", "0", "", "", "1", "1", "1", "20.52", "20.52", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1333, "brand_name": "Glow-worm", "model_name": "Hideaway", "model_qualifier": "80BL", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 23.45, "final_year_of_manufacture": 1994, "raw": ["001333", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Hideaway", "80BL", "4131324", "", "1994", "1", "1", "0", "1", "0", "", "", "1", "2", "1", "23.45", "23.45", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1334, "brand_name": "Glow-worm", "model_name": "Hideaway", "model_qualifier": "80L", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 23.45, "final_year_of_manufacture": 1994, "raw": ["001334", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Hideaway", "80L", "4131325", "", "1994", "1", "1", "0", "1", "0", "", "", "1", "1", "1", "23.45", "23.45", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1336, "brand_name": "Glow-worm", "model_name": "Hideaway", "model_qualifier": "90of", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 26.38, "final_year_of_manufacture": 1999, "raw": ["001336", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Hideaway", "90of", "4131384", "1984", "1999", "1", "1", "0", "1", "0", "", "", "1", "1", "1", "26.38", "26.38", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1337, "brand_name": "Glow-worm", "model_name": "Majorca", "model_qualifier": "240/6", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": null, "final_year_of_manufacture": 1986, "raw": ["001337", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Majorca", "240/6", "3731402", "", "1986", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "", "", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1338, "brand_name": "Glow-worm", "model_name": "Majorca", "model_qualifier": "246", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": null, "final_year_of_manufacture": 1982, "raw": ["001338", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Majorca", "246", "", "", "1982", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "", "", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1339, "brand_name": "Glow-worm", "model_name": "Majorca", "model_qualifier": "340/6", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": null, "final_year_of_manufacture": 1986, "raw": ["001339", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Majorca", "340/6", "3731403", "", "1986", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "", "", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1340, "brand_name": "Glow-worm", "model_name": "Majorca", "model_qualifier": "340/6auto", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": null, "final_year_of_manufacture": 1986, "raw": ["001340", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Majorca", "340/6auto", "3731404", "", "1986", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "", "", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1341, "brand_name": "Glow-worm", "model_name": "Majorca", "model_qualifier": "346", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": null, "final_year_of_manufacture": 1982, "raw": ["001341", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Majorca", "346", "", "", "1982", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "", "", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1354, "brand_name": "Glow-worm", "model_name": "Royale", "model_qualifier": "240/6", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": null, "final_year_of_manufacture": 1986, "raw": ["001354", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Royale", "240/6", "3731401", "", "1986", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "", "", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1355, "brand_name": "Glow-worm", "model_name": "Royale", "model_qualifier": "246", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": null, "final_year_of_manufacture": 1982, "raw": ["001355", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Royale", "246", "4431523", "", "1982", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "", "", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1356, "brand_name": "Glow-worm", "model_name": "Spacesaver", "model_qualifier": "20-30f", "winter_efficiency_pct": 69.0, "summer_efficiency_pct": 59.0, "comparative_hot_water_efficiency_pct": 43.0, "output_kw_max": 8.79, "final_year_of_manufacture": 1989, "raw": ["001356", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Spacesaver", "20-30f", "4131371", "", "1989", "1", "0", "0", "1", "0", "", "", "1", "2", "2", "8.79", "8.79", "", "", "69.0", "59.0", "", "43.0", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1357, "brand_name": "Glow-worm", "model_name": "Spacesaver", "model_qualifier": "20-30rf", "winter_efficiency_pct": 69.0, "summer_efficiency_pct": 59.0, "comparative_hot_water_efficiency_pct": 43.0, "output_kw_max": 8.79, "final_year_of_manufacture": 1989, "raw": ["001357", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Spacesaver", "20-30rf", "4131386", "", "1989", "1", "2", "0", "1", "0", "", "", "1", "2", "2", "8.79", "8.79", "", "", "69.0", "59.0", "", "43.0", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1358, "brand_name": "Glow-worm", "model_name": "Spacesaver", "model_qualifier": "20-30rfs", "winter_efficiency_pct": 69.0, "summer_efficiency_pct": 59.0, "comparative_hot_water_efficiency_pct": 43.0, "output_kw_max": 8.79, "final_year_of_manufacture": 1989, "raw": ["001358", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Spacesaver", "20-30rfs", "4131391", "", "1989", "1", "2", "0", "1", "0", "", "", "1", "2", "2", "8.79", "8.79", "", "", "69.0", "59.0", "", "43.0", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1359, "brand_name": "Glow-worm", "model_name": "Spacesaver", "model_qualifier": "22-30b", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 8.79, "final_year_of_manufacture": 1983, "raw": ["001359", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Spacesaver", "22-30b", "4131569", "", "1983", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "8.79", "8.79", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1360, "brand_name": "Glow-worm", "model_name": "Spacesaver", "model_qualifier": "22-30f", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 8.79, "final_year_of_manufacture": 1984, "raw": ["001360", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Spacesaver", "22-30f", "4131570", "", "1984", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "8.79", "8.79", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1361, "brand_name": "Glow-worm", "model_name": "Spacesaver", "model_qualifier": "30-40f", "winter_efficiency_pct": 69.0, "summer_efficiency_pct": 59.0, "comparative_hot_water_efficiency_pct": 43.0, "output_kw_max": 11.72, "final_year_of_manufacture": 1989, "raw": ["001361", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Spacesaver", "30-40f", "4131368", "", "1989", "1", "0", "0", "1", "0", "", "", "1", "2", "2", "11.72", "11.72", "", "", "69.0", "59.0", "", "43.0", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1362, "brand_name": "Glow-worm", "model_name": "Spacesaver", "model_qualifier": "30-40rf", "winter_efficiency_pct": 69.0, "summer_efficiency_pct": 59.0, "comparative_hot_water_efficiency_pct": 43.0, "output_kw_max": 11.72, "final_year_of_manufacture": 1992, "raw": ["001362", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Spacesaver", "30-40rf", "4131387", "", "1992", "1", "2", "0", "1", "0", "", "", "1", "2", "2", "11.72", "11.72", "", "", "69.0", "59.0", "", "43.0", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1363, "brand_name": "Glow-worm", "model_name": "Spacesaver", "model_qualifier": "30-40rfs", "winter_efficiency_pct": 69.0, "summer_efficiency_pct": 59.0, "comparative_hot_water_efficiency_pct": 43.0, "output_kw_max": 11.72, "final_year_of_manufacture": 1992, "raw": ["001363", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Spacesaver", "30-40rfs", "4131392", "", "1992", "1", "2", "0", "1", "0", "", "", "1", "2", "2", "11.72", "11.72", "", "", "69.0", "59.0", "", "43.0", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1364, "brand_name": "Glow-worm", "model_name": "Spacesaver", "model_qualifier": "30bmk2", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 8.79, "final_year_of_manufacture": 1988, "raw": ["001364", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Spacesaver", "30bmk2", "4131594", "", "1988", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "8.79", "8.79", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1365, "brand_name": "Glow-worm", "model_name": "Spacesaver", "model_qualifier": "30brmk2", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 8.79, "final_year_of_manufacture": 1988, "raw": ["001365", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Spacesaver", "30brmk2", "4131353", "", "1988", "1", "2", "0", "1", "0", "", "", "1", "2", "1", "8.79", "8.79", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1366, "brand_name": "Glow-worm", "model_name": "Spacesaver", "model_qualifier": "30mk2", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 8.79, "final_year_of_manufacture": 1988, "raw": ["001366", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Spacesaver", "30mk2", "4131307", "", "1988", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "8.79", "8.79", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1367, "brand_name": "Glow-worm", "model_name": "Spacesaver", "model_qualifier": "30rmk2", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 8.79, "final_year_of_manufacture": 1993, "raw": ["001367", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Spacesaver", "30rmk2", "4131358", "", "1993", "1", "2", "0", "1", "0", "", "", "1", "1", "1", "8.79", "8.79", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1368, "brand_name": "Glow-worm", "model_name": "Spacesaver", "model_qualifier": "38bf", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 11.1, "final_year_of_manufacture": 1983, "raw": ["001368", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Spacesaver", "38bf", "4131531", "", "1983", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "11.1", "11.1", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1369, "brand_name": "Glow-worm", "model_name": "Spacesaver", "model_qualifier": "38", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 11.14, "final_year_of_manufacture": 1984, "raw": ["001369", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Spacesaver", "38", "4131544", "", "1984", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "11.14", "11.14", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1370, "brand_name": "Glow-worm", "model_name": "Spacesaver", "model_qualifier": "50f", "winter_efficiency_pct": 69.0, "summer_efficiency_pct": 59.0, "comparative_hot_water_efficiency_pct": 43.0, "output_kw_max": 14.65, "final_year_of_manufacture": 1989, "raw": ["001370", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Spacesaver", "50f", "4131370", "", "1989", "1", "0", "0", "1", "0", "", "", "1", "2", "2", "14.65", "14.65", "", "", "69.0", "59.0", "", "43.0", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1371, "brand_name": "Glow-worm", "model_name": "Spacesaver", "model_qualifier": "40-50rf", "winter_efficiency_pct": 69.0, "summer_efficiency_pct": 59.0, "comparative_hot_water_efficiency_pct": 43.0, "output_kw_max": 14.65, "final_year_of_manufacture": 1989, "raw": ["001371", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Spacesaver", "40-50rf", "4131388", "", "1989", "1", "2", "0", "1", "0", "", "", "1", "2", "2", "14.65", "14.65", "", "", "69.0", "59.0", "", "43.0", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1372, "brand_name": "Glow-worm", "model_name": "Spacesaver", "model_qualifier": "40-50rfs", "winter_efficiency_pct": 69.0, "summer_efficiency_pct": 59.0, "comparative_hot_water_efficiency_pct": 43.0, "output_kw_max": 14.65, "final_year_of_manufacture": 1992, "raw": ["001372", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Spacesaver", "40-50rfs", "4131393", "", "1992", "1", "1", "0", "1", "0", "", "", "1", "2", "2", "14.65", "14.65", "", "", "69.0", "59.0", "", "43.0", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1373, "brand_name": "Glow-worm", "model_name": "Spacesaver", "model_qualifier": "40bmk2", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 11.72, "final_year_of_manufacture": 1988, "raw": ["001373", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Spacesaver", "40bmk2", "4131588", "", "1988", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "11.72", "11.72", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1374, "brand_name": "Glow-worm", "model_name": "Spacesaver", "model_qualifier": "40brmk2", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 11.72, "final_year_of_manufacture": 1993, "raw": ["001374", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Spacesaver", "40brmk2", "4131354", "", "1993", "1", "2", "0", "1", "0", "", "", "1", "2", "1", "11.72", "11.72", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1375, "brand_name": "Glow-worm", "model_name": "Spacesaver", "model_qualifier": "40f", "winter_efficiency_pct": 69.0, "summer_efficiency_pct": 59.0, "comparative_hot_water_efficiency_pct": 43.0, "output_kw_max": 11.72, "final_year_of_manufacture": 1988, "raw": ["001375", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Spacesaver", "40f", "4131337", "", "1988", "1", "0", "0", "1", "0", "", "", "1", "2", "2", "11.72", "11.72", "", "", "69.0", "59.0", "", "43.0", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1376, "brand_name": "Glow-worm", "model_name": "Spacesaver", "model_qualifier": "40mk2", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 11.72, "final_year_of_manufacture": 1988, "raw": ["001376", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Spacesaver", "40mk2", "4131589", "", "1988", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "11.72", "11.72", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1377, "brand_name": "Glow-worm", "model_name": "Spacesaver", "model_qualifier": "40rmk2", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 11.72, "final_year_of_manufacture": 1992, "raw": ["001377", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Spacesaver", "40rmk2", "4131359", "", "1992", "1", "2", "0", "1", "0", "", "", "1", "1", "1", "11.72", "11.72", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1378, "brand_name": "Glow-worm", "model_name": "Spacesaver", "model_qualifier": "45-60b", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 17.59, "final_year_of_manufacture": 1984, "raw": ["001378", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Spacesaver", "45-60b", "4131564", "", "1984", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "17.59", "17.59", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1379, "brand_name": "Glow-worm", "model_name": "Spacesaver", "model_qualifier": "45-60", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 17.59, "final_year_of_manufacture": 1984, "raw": ["001379", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Spacesaver", "45-60", "4131563", "", "1984", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "17.59", "17.59", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1381, "brand_name": "Glow-worm", "model_name": "Spacesaver", "model_qualifier": "50-60rf", "winter_efficiency_pct": 69.0, "summer_efficiency_pct": 59.0, "comparative_hot_water_efficiency_pct": 43.0, "output_kw_max": 17.59, "final_year_of_manufacture": 1992, "raw": ["001381", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Spacesaver", "50-60rf", "4131389", "", "1992", "1", "2", "0", "1", "0", "", "", "1", "2", "2", "17.59", "17.59", "", "", "69.0", "59.0", "", "43.0", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1382, "brand_name": "Glow-worm", "model_name": "Spacesaver", "model_qualifier": "50-60rfs", "winter_efficiency_pct": 69.0, "summer_efficiency_pct": 59.0, "comparative_hot_water_efficiency_pct": 43.0, "output_kw_max": 17.59, "final_year_of_manufacture": 1992, "raw": ["001382", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Spacesaver", "50-60rfs", "4131394", "", "1992", "1", "2", "0", "1", "0", "", "", "1", "2", "2", "17.59", "17.59", "", "", "69.0", "59.0", "", "43.0", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1383, "brand_name": "Glow-worm", "model_name": "Spacesaver", "model_qualifier": "50bf", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 14.6, "final_year_of_manufacture": 1982, "raw": ["001383", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Spacesaver", "50bf", "4131527", "", "1982", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "14.6", "14.6", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1384, "brand_name": "Glow-worm", "model_name": "Spacesaver", "model_qualifier": "50bmk2", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 14.65, "final_year_of_manufacture": 1988, "raw": ["001384", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Spacesaver", "50bmk2", "4131571", "", "1988", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "14.65", "14.65", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1386, "brand_name": "Glow-worm", "model_name": "Spacesaver", "model_qualifier": "50mk2", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 14.65, "final_year_of_manufacture": 1988, "raw": ["001386", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Spacesaver", "50mk2", "4131303", "", "1988", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "14.65", "14.65", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1387, "brand_name": "Glow-worm", "model_name": "Spacesaver", "model_qualifier": "50rmk2", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 14.65, "final_year_of_manufacture": 1992, "raw": ["001387", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Spacesaver", "50rmk2", "4131360", "", "1992", "1", "2", "0", "1", "0", "", "", "1", "1", "1", "14.65", "14.65", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1388, "brand_name": "Glow-worm", "model_name": "Spacesaver", "model_qualifier": "52", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 15.24, "final_year_of_manufacture": 1984, "raw": ["001388", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Spacesaver", "52", "4131545", "", "1984", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "15.24", "15.24", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1389, "brand_name": "Glow-worm", "model_name": "Spacesaver", "model_qualifier": "60bmk2", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 17.59, "final_year_of_manufacture": 1988, "raw": ["001389", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Spacesaver", "60bmk2", "4131302", "", "1988", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "17.59", "17.59", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1390, "brand_name": "Glow-worm", "model_name": "Spacesaver", "model_qualifier": "60brmk2", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 17.59, "final_year_of_manufacture": 1992, "raw": ["001390", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Spacesaver", "60brmk2", "4131356", "", "1992", "1", "2", "0", "1", "0", "", "", "1", "2", "1", "17.59", "17.59", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1391, "brand_name": "Glow-worm", "model_name": "Spacesaver", "model_qualifier": "60f", "winter_efficiency_pct": 69.0, "summer_efficiency_pct": 59.0, "comparative_hot_water_efficiency_pct": 43.0, "output_kw_max": 17.59, "final_year_of_manufacture": 1988, "raw": ["001391", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Spacesaver", "60f", "4131336", "", "1988", "1", "0", "0", "1", "0", "", "", "1", "2", "2", "17.59", "17.59", "", "", "69.0", "59.0", "", "43.0", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1392, "brand_name": "Glow-worm", "model_name": "Spacesaver", "model_qualifier": "60mk2", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 17.59, "final_year_of_manufacture": 1988, "raw": ["001392", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Spacesaver", "60mk2", "4131308", "", "1988", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "17.59", "17.59", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1393, "brand_name": "Glow-worm", "model_name": "Spacesaver", "model_qualifier": "60rmk2", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 17.59, "final_year_of_manufacture": 1993, "raw": ["001393", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Spacesaver", "60rmk2", "4131361", "", "1993", "1", "2", "0", "1", "0", "", "", "1", "1", "1", "17.59", "17.59", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1394, "brand_name": "Glow-worm", "model_name": "Spacesaver", "model_qualifier": "65-75f", "winter_efficiency_pct": 69.0, "summer_efficiency_pct": 59.0, "comparative_hot_water_efficiency_pct": 43.0, "output_kw_max": 21.98, "final_year_of_manufacture": null, "raw": ["001394", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Spacesaver", "65-75f", "4131338", "", "obsolete", "1", "2", "0", "1", "0", "", "", "1", "2", "2", "21.98", "21.98", "", "", "69.0", "59.0", "", "43.0", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1395, "brand_name": "Glow-worm", "model_name": "Spacesaver", "model_qualifier": "75bf", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 21.98, "final_year_of_manufacture": 1984, "raw": ["001395", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Spacesaver", "75bf", "4131532", "", "1984", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "21.98", "21.98", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1396, "brand_name": "Glow-worm", "model_name": "Spacesaver", "model_qualifier": "75", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 21.98, "final_year_of_manufacture": 1992, "raw": ["001396", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Spacesaver", "75", "4131546", "", "1992", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "21.98", "21.98", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1397, "brand_name": "Glow-worm", "model_name": "Spacesaver", "model_qualifier": "80bmk2", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 23.45, "final_year_of_manufacture": 1988, "raw": ["001397", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Spacesaver", "80bmk2", "4131305", "", "1988", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "23.45", "23.45", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1398, "brand_name": "Glow-worm", "model_name": "Spacesaver", "model_qualifier": "80brmk2", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 23.45, "final_year_of_manufacture": 1992, "raw": ["001398", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Spacesaver", "80brmk2", "4131357", "", "1992", "1", "2", "0", "1", "0", "", "", "1", "2", "1", "23.45", "23.45", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1399, "brand_name": "Glow-worm", "model_name": "Suburban", "model_qualifier": "Suburban", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": null, "final_year_of_manufacture": 1974, "raw": ["001399", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Suburban", "Suburban", "4431504", "", "1974", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "", "", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1400, "brand_name": "Glow-worm", "model_name": "Super", "model_qualifier": "30", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 8.79, "final_year_of_manufacture": 1985, "raw": ["001400", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Super", "30", "4131577", "", "1985", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "8.79", "8.79", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1401, "brand_name": "Glow-worm", "model_name": "Super", "model_qualifier": "30b", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 8.79, "final_year_of_manufacture": 1984, "raw": ["001401", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Super", "30b", "4131578", "", "1984", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "8.79", "8.79", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1402, "brand_name": "Glow-worm", "model_name": "Super", "model_qualifier": "40", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 11.7, "final_year_of_manufacture": 1984, "raw": ["001402", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Super", "40", "4131565", "", "1984", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "11.7", "11.7", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1403, "brand_name": "Glow-worm", "model_name": "Super", "model_qualifier": "40b", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 11.7, "final_year_of_manufacture": 1984, "raw": ["001403", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Super", "40b", "4131566", "", "1984", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "11.7", "11.7", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1404, "brand_name": "Glow-worm", "model_name": "Super", "model_qualifier": "52", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 15.2, "final_year_of_manufacture": 1985, "raw": ["001404", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Super", "52", "4131547", "", "1985", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "15.2", "15.2", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1405, "brand_name": "Glow-worm", "model_name": "Super", "model_qualifier": "52b", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 15.2, "final_year_of_manufacture": 1985, "raw": ["001405", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Super", "52b", "4131548", "", "1985", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "15.2", "15.2", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1422, "brand_name": "Glow-worm", "model_name": "Ultimate", "model_qualifier": "80bf", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 23.45, "final_year_of_manufacture": 1998, "raw": ["001422", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Ultimate", "80bf", "4131955", "", "1998", "1", "2", "0", "1", "0", "", "", "1", "2", "1", "23.45", "23.45", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1424, "brand_name": "Glow-worm", "model_name": "Swiftflow", "model_qualifier": "75", "winter_efficiency_pct": 71.0, "summer_efficiency_pct": 62.0, "comparative_hot_water_efficiency_pct": 43.2, "output_kw_max": 16.1, "final_year_of_manufacture": null, "raw": ["001424", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Swiftflow", "75", "", "", "obsolete", "1", "0", "0", "2", "0", "", "", "1", "2", "2", "16.1", "16.1", "", "", "71.0", "62.0", "", "43.2", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1425, "brand_name": "Glow-worm", "model_name": "Swiftflow", "model_qualifier": "80", "winter_efficiency_pct": 71.0, "summer_efficiency_pct": 62.0, "comparative_hot_water_efficiency_pct": 43.2, "output_kw_max": 17.6, "final_year_of_manufacture": null, "raw": ["001425", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Swiftflow", "80", "", "", "obsolete", "1", "0", "0", "2", "0", "", "", "1", "2", "2", "17.6", "17.6", "", "", "71.0", "62.0", "", "43.2", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1426, "brand_name": "Glow-worm", "model_name": "Swiftflow", "model_qualifier": "100", "winter_efficiency_pct": 71.0, "summer_efficiency_pct": 62.0, "comparative_hot_water_efficiency_pct": 43.2, "output_kw_max": 17.6, "final_year_of_manufacture": null, "raw": ["001426", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Swiftflow", "100", "", "", "obsolete", "1", "0", "0", "2", "0", "", "", "1", "2", "2", "17.6", "17.6", "", "", "71.0", "62.0", "", "43.2", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1434, "brand_name": "Glow-worm", "model_name": "Fuelsaver Economy Plus", "model_qualifier": "24B", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 7.03, "final_year_of_manufacture": null, "raw": ["001434", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Fuelsaver Economy Plus", "24B", "", "", "obsolete", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "7.03", "7.03", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1435, "brand_name": "Glow-worm", "model_name": "Fuelsaver Economy Plus", "model_qualifier": "30B", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 8.79, "final_year_of_manufacture": null, "raw": ["001435", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Fuelsaver Economy Plus", "30B", "", "", "obsolete", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "8.79", "8.79", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1436, "brand_name": "Glow-worm", "model_name": "Fuelsaver Economy Plus", "model_qualifier": "40B", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 11.72, "final_year_of_manufacture": null, "raw": ["001436", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Fuelsaver Economy Plus", "40B", "", "", "obsolete", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "11.72", "11.72", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1438, "brand_name": "Glow-worm", "model_name": "Fuelsaver Economy Plus", "model_qualifier": "60B", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 17.59, "final_year_of_manufacture": null, "raw": ["001438", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Fuelsaver Economy Plus", "60B", "", "", "obsolete", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "17.59", "17.59", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1439, "brand_name": "Glow-worm", "model_name": "Fuelsaver Economy Plus", "model_qualifier": "24F", "winter_efficiency_pct": 69.0, "summer_efficiency_pct": 59.0, "comparative_hot_water_efficiency_pct": 43.0, "output_kw_max": 7.03, "final_year_of_manufacture": null, "raw": ["001439", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Fuelsaver Economy Plus", "24F", "", "", "obsolete", "1", "0", "0", "1", "0", "", "", "1", "2", "2", "7.03", "7.03", "", "", "69.0", "59.0", "", "43.0", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1440, "brand_name": "Glow-worm", "model_name": "Fuelsaver Economy Plus", "model_qualifier": "30F", "winter_efficiency_pct": 69.0, "summer_efficiency_pct": 59.0, "comparative_hot_water_efficiency_pct": 43.0, "output_kw_max": 8.79, "final_year_of_manufacture": null, "raw": ["001440", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Fuelsaver Economy Plus", "30F", "", "", "obsolete", "1", "0", "0", "1", "0", "", "", "1", "2", "2", "8.79", "8.79", "", "", "69.0", "59.0", "", "43.0", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1441, "brand_name": "Glow-worm", "model_name": "Fuelsaver Economy Plus", "model_qualifier": "40F", "winter_efficiency_pct": 69.0, "summer_efficiency_pct": 59.0, "comparative_hot_water_efficiency_pct": 43.0, "output_kw_max": 11.72, "final_year_of_manufacture": null, "raw": ["001441", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Fuelsaver Economy Plus", "40F", "", "", "obsolete", "1", "0", "0", "1", "0", "", "", "1", "2", "2", "11.72", "11.72", "", "", "69.0", "59.0", "", "43.0", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1442, "brand_name": "Glow-worm", "model_name": "Fuelsaver Economy Plus", "model_qualifier": "50F", "winter_efficiency_pct": 69.0, "summer_efficiency_pct": 59.0, "comparative_hot_water_efficiency_pct": 43.0, "output_kw_max": 14.65, "final_year_of_manufacture": null, "raw": ["001442", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Fuelsaver Economy Plus", "50F", "", "", "obsolete", "1", "0", "0", "1", "0", "", "", "1", "2", "2", "14.65", "14.65", "", "", "69.0", "59.0", "", "43.0", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1443, "brand_name": "Glow-worm", "model_name": "Fuelsaver Economy Plus", "model_qualifier": "60F", "winter_efficiency_pct": 69.0, "summer_efficiency_pct": 59.0, "comparative_hot_water_efficiency_pct": 43.0, "output_kw_max": 17.58, "final_year_of_manufacture": null, "raw": ["001443", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Fuelsaver Economy Plus", "60F", "", "", "obsolete", "1", "0", "0", "1", "0", "", "", "1", "2", "2", "17.58", "17.58", "", "", "69.0", "59.0", "", "43.0", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1444, "brand_name": "Glow-worm", "model_name": "Fuelsaver Economy Plus", "model_qualifier": "80F", "winter_efficiency_pct": 69.0, "summer_efficiency_pct": 59.0, "comparative_hot_water_efficiency_pct": 43.0, "output_kw_max": 23.45, "final_year_of_manufacture": null, "raw": ["001444", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Fuelsaver Economy Plus", "80F", "", "", "obsolete", "1", "0", "0", "1", "0", "", "", "1", "2", "2", "23.45", "23.45", "", "", "69.0", "59.0", "", "43.0", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1446, "brand_name": "Glow-worm", "model_name": "Fuelsaver Economy Plus", "model_qualifier": "40C", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 11.7, "final_year_of_manufacture": null, "raw": ["001446", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Fuelsaver Economy Plus", "40C", "", "", "obsolete", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "11.7", "11.7", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1447, "brand_name": "Glow-worm", "model_name": "Fuelsaver Economy Plus", "model_qualifier": "50C", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 14.65, "final_year_of_manufacture": null, "raw": ["001447", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Fuelsaver Economy Plus", "50C", "", "", "obsolete", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "14.65", "14.65", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1448, "brand_name": "Glow-worm", "model_name": "Fuelsaver Economy Plus", "model_qualifier": "60C", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 17.59, "final_year_of_manufacture": null, "raw": ["001448", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Fuelsaver Economy Plus", "60C", "", "", "obsolete", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "17.59", "17.59", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1464, "brand_name": "Maxol", "model_name": "Eastham", "model_qualifier": "25bf", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 7.62, "final_year_of_manufacture": 1980, "raw": ["001464", "000007", "0", "2010/Sep/13 17:03", "Maxol", "Maxol", "Eastham", "25bf", "4120207", "", "1980", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "7.62", "7.62", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1465, "brand_name": "Maxol", "model_name": "Eastham", "model_qualifier": "25of", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 7.62, "final_year_of_manufacture": 1980, "raw": ["001465", "000007", "0", "2010/Sep/13 17:03", "Maxol", "Maxol", "Eastham", "25of", "4120208", "", "1980", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "7.62", "7.62", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1467, "brand_name": "Maxol", "model_name": "Eastham", "model_qualifier": "40bf", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 13.19, "final_year_of_manufacture": 1980, "raw": ["001467", "000007", "0", "2010/Sep/13 17:03", "Maxol", "Maxol", "Eastham", "40bf", "4120209", "", "1980", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "13.19", "13.19", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1468, "brand_name": "Maxol", "model_name": "Eastham", "model_qualifier": "50", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 16.12, "final_year_of_manufacture": 1980, "raw": ["001468", "000007", "0", "2010/Sep/13 17:03", "Maxol", "Maxol", "Eastham", "50", "4120203", "", "1980", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "16.12", "16.12", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1469, "brand_name": "Maxol", "model_name": "Homewarm", "model_qualifier": "600", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 6.0, "final_year_of_manufacture": 1986, "raw": ["001469", "000007", "0", "2010/Sep/13 17:03", "Maxol", "Maxol", "Homewarm", "600", "4120210", "", "1986", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "6", "6", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1470, "brand_name": "Maxol", "model_name": "Marathon", "model_qualifier": "e", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": null, "final_year_of_manufacture": 1975, "raw": ["001470", "000007", "0", "2010/Sep/13 17:03", "Maxol", "Maxol", "Marathon", "e", "4420202", "", "1975", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "", "", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1471, "brand_name": "Maxol", "model_name": "Marathon", "model_qualifier": "mk1", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": null, "final_year_of_manufacture": 1975, "raw": ["001471", "000007", "0", "2010/Sep/13 17:03", "Maxol", "Maxol", "Marathon", "mk1", "4420201", "", "1975", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "", "", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1472, "brand_name": "Maxol", "model_name": "Marathon", "model_qualifier": "mk1r", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": null, "final_year_of_manufacture": 1975, "raw": ["001472", "000007", "0", "2010/Sep/13 17:03", "Maxol", "Maxol", "Marathon", "mk1r", "4420204", "", "1975", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "", "", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1473, "brand_name": "Maxol", "model_name": "Marathon", "model_qualifier": "r", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": null, "final_year_of_manufacture": 1975, "raw": ["001473", "000007", "0", "2010/Sep/13 17:03", "Maxol", "Maxol", "Marathon", "r", "4420205", "", "1975", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "", "", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1474, "brand_name": "Maxol", "model_name": "Maxolympic", "model_qualifier": "15", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": null, "final_year_of_manufacture": 1977, "raw": ["001474", "000007", "0", "2010/Sep/13 17:03", "Maxol", "Maxol", "Maxolympic", "15", "3920201", "", "1977", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "", "", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1475, "brand_name": "Maxol", "model_name": "Maxolympic", "model_qualifier": "f15", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": null, "final_year_of_manufacture": 1977, "raw": ["001475", "000007", "0", "2010/Sep/13 17:03", "Maxol", "Maxol", "Maxolympic", "f15", "3920202", "", "1977", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "", "", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1476, "brand_name": "Maxol", "model_name": "Maxolympic", "model_qualifier": "f20", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": null, "final_year_of_manufacture": 1977, "raw": ["001476", "000007", "0", "2010/Sep/13 17:03", "Maxol", "Maxol", "Maxolympic", "f20", "4420208", "", "1977", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "", "", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1477, "brand_name": "Maxol", "model_name": "Microturbo", "model_qualifier": "40mdf", "winter_efficiency_pct": 73.0, "summer_efficiency_pct": 63.0, "comparative_hot_water_efficiency_pct": 45.9, "output_kw_max": 11.72, "final_year_of_manufacture": 1992, "raw": ["001477", "000007", "0", "2015/Jul/21 14:15", "Maxol", "Maxol", "Microturbo", "40mdf", "4120215", "", "1992", "1", "0", "0", "1", "0", "", "", "1", "2", "2", "11.72", "11.72", "", "", "73.0", "63.0", "", "45.9", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1478, "brand_name": "Maxol", "model_name": "Microturbo", "model_qualifier": "40rf", "winter_efficiency_pct": 73.0, "summer_efficiency_pct": 63.0, "comparative_hot_water_efficiency_pct": 45.9, "output_kw_max": 11.72, "final_year_of_manufacture": 1992, "raw": ["001478", "000007", "0", "2015/Jul/21 14:15", "Maxol", "Maxol", "Microturbo", "40rf", "4120217", "", "1992", "1", "0", "0", "1", "0", "", "", "1", "2", "2", "11.72", "11.72", "", "", "73.0", "63.0", "", "45.9", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1479, "brand_name": "Maxol", "model_name": "Microturbo", "model_qualifier": "50mdf", "winter_efficiency_pct": 73.0, "summer_efficiency_pct": 63.0, "comparative_hot_water_efficiency_pct": 45.9, "output_kw_max": 14.6, "final_year_of_manufacture": 1995, "raw": ["001479", "000007", "0", "2015/Jul/21 14:15", "Maxol", "Maxol", "Microturbo", "50mdf", "4120219", "", "1995", "1", "0", "0", "1", "0", "", "", "1", "2", "2", "14.6", "14.6", "", "", "73.0", "63.0", "", "45.9", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1480, "brand_name": "Maxol", "model_name": "Microturbo", "model_qualifier": "50rf", "winter_efficiency_pct": 73.0, "summer_efficiency_pct": 63.0, "comparative_hot_water_efficiency_pct": 45.9, "output_kw_max": 14.6, "final_year_of_manufacture": 1995, "raw": ["001480", "000007", "0", "2015/Jul/21 14:15", "Maxol", "Maxol", "Microturbo", "50rf", "4120218", "", "1995", "1", "0", "0", "1", "0", "", "", "1", "2", "2", "14.6", "14.6", "", "", "73.0", "63.0", "", "45.9", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1485, "brand_name": "Maxol", "model_name": "Mystique", "model_qualifier": "coalridge", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": null, "final_year_of_manufacture": 1988, "raw": ["001485", "000007", "0", "2010/Sep/13 17:03", "Maxol", "Maxol", "Mystique", "coalridge", "4420210", "", "1988", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "", "", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1486, "brand_name": "Maxol", "model_name": "Ruud", "model_qualifier": "118", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 34.6, "final_year_of_manufacture": 1975, "raw": ["001486", "000007", "0", "2010/Sep/13 17:03", "Maxol", "Maxol", "Ruud", "118", "4120201", "", "1975", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "34.6", "34.6", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1494, "brand_name": "Thorn EMI Heating", "model_name": "Apollo", "model_qualifier": "30b", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 8.8, "final_year_of_manufacture": 1998, "raw": ["001494", "000005", "0", "2010/Sep/13 17:03", "Thorn EMI Heating", "Thorn EMI Heating", "Apollo", "30b", "4149422", "", "1998", "1", "2", "1", "1", "0", "", "", "1", "2", "1", "4.4", "8.8", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "1", "20", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1495, "brand_name": "Thorn EMI Heating", "model_name": "Apollo", "model_qualifier": "30c", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 8.8, "final_year_of_manufacture": 1998, "raw": ["001495", "000005", "0", "2010/Sep/13 17:03", "Thorn EMI Heating", "Thorn EMI Heating", "Apollo", "30c", "4149427", "", "1998", "1", "2", "1", "1", "0", "", "", "1", "1", "1", "4.4", "8.8", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "1", "20", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1496, "brand_name": "Thorn EMI Heating", "model_name": "Apollo", "model_qualifier": "30s", "winter_efficiency_pct": 73.0, "summer_efficiency_pct": 63.0, "comparative_hot_water_efficiency_pct": 45.9, "output_kw_max": 8.8, "final_year_of_manufacture": 1997, "raw": ["001496", "000005", "0", "2015/Jul/21 14:15", "Thorn EMI Heating", "Thorn EMI Heating", "Apollo", "30s", "4149432", "", "1997", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "4.4", "8.8", "", "", "73.0", "63.0", "", "45.9", "", "3", "", "", "0", "2", "1", "60", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1497, "brand_name": "Thorn EMI Heating", "model_name": "Apollo", "model_qualifier": "30si", "winter_efficiency_pct": 73.0, "summer_efficiency_pct": 63.0, "comparative_hot_water_efficiency_pct": 45.9, "output_kw_max": 8.8, "final_year_of_manufacture": 1998, "raw": ["001497", "000005", "0", "2015/Jul/21 14:15", "Thorn EMI Heating", "Thorn EMI Heating", "Apollo", "30si", "4149437", "", "1998", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "4.4", "8.8", "", "", "73.0", "63.0", "", "45.9", "", "3", "", "", "0", "1", "1", "60", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1498, "brand_name": "Thorn EMI Heating", "model_name": "Apollo", "model_qualifier": "40b", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 11.7, "final_year_of_manufacture": 1998, "raw": ["001498", "000005", "0", "2010/Sep/13 17:03", "Thorn EMI Heating", "Thorn EMI Heating", "Apollo", "40b", "4149423", "", "1998", "1", "2", "1", "1", "0", "", "", "1", "2", "1", "8.8", "11.7", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "1", "20", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1499, "brand_name": "Thorn EMI Heating", "model_name": "Apollo", "model_qualifier": "40c", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 11.7, "final_year_of_manufacture": 1998, "raw": ["001499", "000005", "0", "2010/Sep/13 17:03", "Thorn EMI Heating", "Thorn EMI Heating", "Apollo", "40c", "4149428", "", "1998", "1", "2", "1", "1", "0", "", "", "1", "1", "1", "8.8", "11.7", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "1", "20", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1500, "brand_name": "Thorn EMI Heating", "model_name": "Apollo", "model_qualifier": "40s", "winter_efficiency_pct": 73.0, "summer_efficiency_pct": 63.0, "comparative_hot_water_efficiency_pct": 45.9, "output_kw_max": 11.7, "final_year_of_manufacture": 1997, "raw": ["001500", "000005", "0", "2015/Jul/21 14:15", "Thorn EMI Heating", "Thorn EMI Heating", "Apollo", "40s", "4149433", "", "1997", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "8.8", "11.7", "", "", "73.0", "63.0", "", "45.9", "", "3", "", "", "0", "2", "1", "60", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1501, "brand_name": "Thorn EMI Heating", "model_name": "Apollo", "model_qualifier": "40si", "winter_efficiency_pct": 73.0, "summer_efficiency_pct": 63.0, "comparative_hot_water_efficiency_pct": 45.9, "output_kw_max": 11.7, "final_year_of_manufacture": 1998, "raw": ["001501", "000005", "0", "2015/Jul/21 14:15", "Thorn EMI Heating", "Thorn EMI Heating", "Apollo", "40si", "4149438", "", "1998", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "8.8", "11.7", "", "", "73.0", "63.0", "", "45.9", "", "3", "", "", "0", "1", "1", "60", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1502, "brand_name": "Thorn EMI Heating", "model_name": "Apollo", "model_qualifier": "50b", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 14.7, "final_year_of_manufacture": 1998, "raw": ["001502", "000005", "0", "2010/Sep/13 17:03", "Thorn EMI Heating", "Thorn EMI Heating", "Apollo", "50b", "4149424", "", "1998", "1", "2", "1", "1", "0", "", "", "1", "2", "1", "11.7", "14.7", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "1", "20", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1503, "brand_name": "Thorn EMI Heating", "model_name": "Apollo", "model_qualifier": "50c", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 14.7, "final_year_of_manufacture": 1998, "raw": ["001503", "000005", "0", "2010/Sep/13 17:03", "Thorn EMI Heating", "Thorn EMI Heating", "Apollo", "50c", "4149429", "", "1998", "1", "2", "1", "1", "0", "", "", "1", "1", "1", "11.7", "14.7", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "1", "20", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1504, "brand_name": "Thorn EMI Heating", "model_name": "Apollo", "model_qualifier": "50s", "winter_efficiency_pct": 73.0, "summer_efficiency_pct": 63.0, "comparative_hot_water_efficiency_pct": 45.9, "output_kw_max": 14.7, "final_year_of_manufacture": 1997, "raw": ["001504", "000005", "0", "2015/Jul/21 14:15", "Thorn EMI Heating", "Thorn EMI Heating", "Apollo", "50s", "4149434", "", "1997", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "11.7", "14.7", "", "", "73.0", "63.0", "", "45.9", "", "3", "", "", "0", "2", "1", "60", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1505, "brand_name": "Thorn EMI Heating", "model_name": "Apollo", "model_qualifier": "50si", "winter_efficiency_pct": 73.0, "summer_efficiency_pct": 63.0, "comparative_hot_water_efficiency_pct": 45.9, "output_kw_max": 14.7, "final_year_of_manufacture": 1998, "raw": ["001505", "000005", "0", "2015/Jul/21 14:15", "Thorn EMI Heating", "Thorn EMI Heating", "Apollo", "50si", "4149439", "", "1998", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "11.7", "14.7", "", "", "73.0", "63.0", "", "45.9", "", "3", "", "", "0", "1", "1", "60", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1506, "brand_name": "Thorn EMI Heating", "model_name": "Apollo", "model_qualifier": "60b", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 17.6, "final_year_of_manufacture": 1998, "raw": ["001506", "000005", "0", "2010/Sep/13 17:03", "Thorn EMI Heating", "Thorn EMI Heating", "Apollo", "60b", "4149425", "", "1998", "1", "2", "1", "1", "0", "", "", "1", "2", "1", "14.7", "17.6", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "1", "20", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1507, "brand_name": "Thorn EMI Heating", "model_name": "Apollo", "model_qualifier": "60c", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 17.6, "final_year_of_manufacture": 1998, "raw": ["001507", "000005", "0", "2010/Sep/13 17:03", "Thorn EMI Heating", "Thorn EMI Heating", "Apollo", "60c", "4149430", "", "1998", "1", "2", "1", "1", "0", "", "", "1", "1", "1", "14.7", "17.6", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "1", "20", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1508, "brand_name": "Thorn EMI Heating", "model_name": "Apollo", "model_qualifier": "60si", "winter_efficiency_pct": 73.0, "summer_efficiency_pct": 63.0, "comparative_hot_water_efficiency_pct": 45.9, "output_kw_max": 17.6, "final_year_of_manufacture": null, "raw": ["001508", "000005", "0", "2015/Jul/21 14:15", "Thorn EMI Heating", "Thorn EMI Heating", "Apollo", "60si", "4149440", "", "obsolete", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "14.7", "17.6", "", "", "73.0", "63.0", "", "45.9", "", "3", "", "", "0", "1", "1", "60", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1509, "brand_name": "Thorn EMI Heating", "model_name": "Apollo", "model_qualifier": "80b", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 23.4, "final_year_of_manufacture": 1998, "raw": ["001509", "000005", "0", "2010/Sep/13 17:03", "Thorn EMI Heating", "Thorn EMI Heating", "Apollo", "80b", "4149426", "", "1998", "1", "2", "1", "1", "0", "", "", "1", "2", "1", "17.6", "23.4", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "1", "20", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1510, "brand_name": "Thorn EMI Heating", "model_name": "Apollo", "model_qualifier": "80c", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 23.4, "final_year_of_manufacture": 1998, "raw": ["001510", "000005", "0", "2010/Sep/13 17:03", "Thorn EMI Heating", "Thorn EMI Heating", "Apollo", "80c", "4149431", "", "1998", "1", "2", "1", "1", "0", "", "", "1", "1", "1", "17.6", "23.4", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "1", "20", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1511, "brand_name": "Thorn EMI Heating", "model_name": "Apollo", "model_qualifier": "80si", "winter_efficiency_pct": 73.0, "summer_efficiency_pct": 63.0, "comparative_hot_water_efficiency_pct": 45.9, "output_kw_max": 23.4, "final_year_of_manufacture": 1998, "raw": ["001511", "000005", "0", "2015/Jul/21 14:15", "Thorn EMI Heating", "Thorn EMI Heating", "Apollo", "80si", "4149441", "", "1998", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "17.6", "23.4", "", "", "73.0", "63.0", "", "45.9", "", "3", "", "", "0", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1512, "brand_name": "Potterton Myson Heating", "model_name": "Economist", "model_qualifier": "wm15/30bf", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 8.8, "final_year_of_manufacture": 1987, "raw": ["001512", "000005", "0", "2010/Sep/13 17:03", "Potterton Myson Heating", "Potterton Myson Heating", "Economist", "wm15/30bf", "4183881", "", "1987", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "8.8", "8.8", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1513, "brand_name": "Myson Combustion Products", "model_name": "Economist", "model_qualifier": "wm15/30bfa", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 8.8, "final_year_of_manufacture": 1997, "raw": ["001513", "000005", "0", "2010/Sep/13 17:03", "Myson Combustion Products", "Myson Combustion Products", "Economist", "wm15/30bfa", "4183890", "", "1997", "1", "2", "1", "1", "0", "", "", "1", "2", "1", "4.4", "8.8", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1514, "brand_name": "Myson Combustion Products", "model_name": "Economist", "model_qualifier": "wm30/40bf", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 11.7, "final_year_of_manufacture": 1997, "raw": ["001514", "000005", "0", "2010/Sep/13 17:03", "Myson Combustion Products", "Myson Combustion Products", "Economist", "wm30/40bf", "4183882", "", "1997", "1", "2", "1", "1", "0", "", "", "1", "2", "1", "8.8", "11.7", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1515, "brand_name": "Myson Combustion Products", "model_name": "Economist", "model_qualifier": "wm40/50bf", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 14.7, "final_year_of_manufacture": 1997, "raw": ["001515", "000005", "0", "2010/Sep/13 17:03", "Myson Combustion Products", "Myson Combustion Products", "Economist", "wm40/50bf", "4183885", "", "1997", "1", "2", "1", "1", "0", "", "", "1", "2", "1", "11.7", "14.7", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1516, "brand_name": "Myson Combustion Products", "model_name": "Economist", "model_qualifier": "wm50/60bf", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 17.6, "final_year_of_manufacture": 1997, "raw": ["001516", "000005", "0", "2010/Sep/13 17:03", "Myson Combustion Products", "Myson Combustion Products", "Economist", "wm50/60bf", "4183884", "", "1997", "1", "2", "1", "1", "0", "", "", "1", "2", "1", "14.7", "17.6", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1517, "brand_name": "Myson Combustion Products", "model_name": "Economist", "model_qualifier": "wm60/80bf", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 23.5, "final_year_of_manufacture": 1997, "raw": ["001517", "000005", "0", "2010/Sep/13 17:03", "Myson Combustion Products", "Myson Combustion Products", "Economist", "wm60/80bf", "4183888", "", "1997", "1", "2", "1", "1", "0", "", "", "1", "2", "1", "17.6", "23.5", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1518, "brand_name": "Myson Combustion Products", "model_name": "Economist", "model_qualifier": "wm80/100bf", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 28.4, "final_year_of_manufacture": 1997, "raw": ["001518", "000005", "0", "2010/Sep/13 17:03", "Myson Combustion Products", "Myson Combustion Products", "Economist", "wm80/100bf", "4183889", "", "1997", "1", "2", "1", "1", "0", "", "", "1", "2", "1", "23.5", "28.4", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1519, "brand_name": "Thorn EMI Heating", "model_name": "Housewarmer", "model_qualifier": "30/45economy", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": null, "final_year_of_manufacture": 1988, "raw": ["001519", "000005", "0", "2010/Sep/13 17:03", "Thorn EMI Heating", "Thorn EMI Heating", "Housewarmer", "30/45economy", "4478915", "", "1988", "1", "4", "1", "1", "0", "", "", "1", "1", "1", "", "", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1520, "brand_name": "Thorn EMI Heating", "model_name": "Housewarmer", "model_qualifier": "30/45elegant", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": null, "final_year_of_manufacture": 1988, "raw": ["001520", "000005", "0", "2010/Sep/13 17:03", "Thorn EMI Heating", "Thorn EMI Heating", "Housewarmer", "30/45elegant", "4478916", "", "1988", "1", "4", "0", "1", "0", "", "", "1", "1", "1", "", "", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1521, "brand_name": "Thorn EMI Heating", "model_name": "Housewarmer", "model_qualifier": "30/45epic", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": null, "final_year_of_manufacture": 1987, "raw": ["001521", "000005", "0", "2010/Sep/13 17:03", "Thorn EMI Heating", "Thorn EMI Heating", "Housewarmer", "30/45epic", "4478917", "", "1987", "1", "4", "0", "1", "0", "", "", "1", "1", "1", "", "", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1522, "brand_name": "Thorn EMI Heating", "model_name": "Housewarmer", "model_qualifier": "30/45epictc", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": null, "final_year_of_manufacture": 1990, "raw": ["001522", "000005", "0", "2010/Sep/13 17:03", "Thorn EMI Heating", "Thorn EMI Heating", "Housewarmer", "30/45epictc", "4449401", "", "1990", "1", "4", "0", "1", "0", "", "", "1", "1", "1", "", "", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1523, "brand_name": "Thorn EMI Heating", "model_name": "Housewarmer", "model_qualifier": "30/45extratc", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": null, "final_year_of_manufacture": 1987, "raw": ["001523", "000005", "0", "2010/Sep/13 17:03", "Thorn EMI Heating", "Thorn EMI Heating", "Housewarmer", "30/45extratc", "4478923", "", "1987", "1", "4", "0", "1", "0", "", "", "1", "1", "1", "", "", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1524, "brand_name": "Thorn EMI Heating", "model_name": "Housewarmer", "model_qualifier": "30/45sable", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": null, "final_year_of_manufacture": 1990, "raw": ["001524", "000005", "0", "2010/Sep/13 17:03", "Thorn EMI Heating", "Thorn EMI Heating", "Housewarmer", "30/45sable", "4449402", "", "1990", "1", "4", "0", "1", "0", "", "", "1", "1", "1", "", "", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1525, "brand_name": "Thorn EMI Heating", "model_name": "Housewarmer", "model_qualifier": "30/45snug", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": null, "final_year_of_manufacture": 1987, "raw": ["001525", "000005", "0", "2010/Sep/13 17:03", "Thorn EMI Heating", "Thorn EMI Heating", "Housewarmer", "30/45snug", "4478918", "", "1987", "1", "4", "0", "1", "0", "", "", "1", "1", "1", "", "", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1526, "brand_name": "Thorn EMI Heating", "model_name": "Housewarmer", "model_qualifier": "30/45spectacular", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": null, "final_year_of_manufacture": 1988, "raw": ["001526", "000005", "0", "2010/Sep/13 17:03", "Thorn EMI Heating", "Thorn EMI Heating", "Housewarmer", "30/45spectacular", "4478922", "", "1988", "1", "4", "0", "1", "0", "", "", "1", "1", "1", "", "", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1527, "brand_name": "Thorn EMI Heating", "model_name": "Housewarmer", "model_qualifier": "30/45superior", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": null, "final_year_of_manufacture": 1990, "raw": ["001527", "000005", "0", "2010/Sep/13 17:03", "Thorn EMI Heating", "Thorn EMI Heating", "Housewarmer", "30/45superior", "4478919", "", "1990", "1", "4", "0", "1", "0", "", "", "1", "1", "1", "", "", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1528, "brand_name": "Thorn EMI Heating", "model_name": "Housewarmer", "model_qualifier": "30/45supreme", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": null, "final_year_of_manufacture": 1990, "raw": ["001528", "000005", "0", "2010/Sep/13 17:03", "Thorn EMI Heating", "Thorn EMI Heating", "Housewarmer", "30/45supreme", "4478920", "", "1990", "1", "4", "0", "1", "0", "", "", "1", "1", "1", "", "", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1529, "brand_name": "Thorn EMI Heating", "model_name": "Housewarmer", "model_qualifier": "45", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": null, "final_year_of_manufacture": 1994, "raw": ["001529", "000005", "0", "2010/Sep/13 17:03", "Thorn EMI Heating", "Thorn EMI Heating", "Housewarmer", "45", "", "", "1994", "1", "4", "0", "1", "0", "", "", "1", "1", "1", "", "", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1530, "brand_name": "Thorn EMI Heating", "model_name": "Housewarmer", "model_qualifier": "55", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": null, "final_year_of_manufacture": 1994, "raw": ["001530", "000005", "0", "2010/Sep/13 17:03", "Thorn EMI Heating", "Thorn EMI Heating", "Housewarmer", "55", "", "", "1994", "1", "4", "0", "1", "0", "", "", "1", "1", "1", "", "", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1531, "brand_name": "Thorn EMI Heating", "model_name": "Housewarmer", "model_qualifier": "deluxe", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": null, "final_year_of_manufacture": 1981, "raw": ["001531", "000005", "0", "2010/Sep/13 17:03", "Thorn EMI Heating", "Thorn EMI Heating", "Housewarmer", "deluxe", "4478909", "", "1981", "1", "4", "0", "1", "0", "", "", "1", "1", "1", "", "", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1532, "brand_name": "Thorn EMI Heating", "model_name": "Housewarmer", "model_qualifier": "elite", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": null, "final_year_of_manufacture": 1990, "raw": ["001532", "000005", "0", "2010/Sep/13 17:03", "Thorn EMI Heating", "Thorn EMI Heating", "Housewarmer", "elite", "4449403", "", "1990", "1", "4", "0", "1", "0", "", "", "1", "1", "1", "", "", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1534, "brand_name": "Thorn EMI Heating", "model_name": "Housewarmer", "model_qualifier": "emodel", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": null, "final_year_of_manufacture": 1976, "raw": ["001534", "000005", "0", "2010/Sep/13 17:03", "Thorn EMI Heating", "Thorn EMI Heating", "Housewarmer", "emodel", "4478903", "", "1976", "1", "4", "0", "1", "0", "", "", "1", "1", "1", "", "", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1535, "brand_name": "Thorn EMI Heating", "model_name": "Housewarmer", "model_qualifier": "smodel", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": null, "final_year_of_manufacture": 1981, "raw": ["001535", "000005", "0", "2010/Sep/13 17:03", "Thorn EMI Heating", "Thorn EMI Heating", "Housewarmer", "smodel", "4478907", "", "1981", "1", "4", "0", "1", "0", "", "", "1", "1", "1", "", "", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1536, "brand_name": "Potterton Myson Heating", "model_name": "Housewarmer", "model_qualifier": "smodel", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": null, "final_year_of_manufacture": 1976, "raw": ["001536", "000005", "0", "2010/Sep/13 17:03", "Potterton Myson Heating", "Potterton Myson Heating", "Housewarmer", "smodel", "4478904", "", "1976", "1", "4", "0", "1", "0", "", "", "1", "1", "1", "", "", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1537, "brand_name": "Thorn EMI Heating", "model_name": "Housewarmer", "model_qualifier": "spectaculardeluxe", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": null, "final_year_of_manufacture": 1990, "raw": ["001537", "000005", "0", "2015/Jul/13 13:45", "Thorn EMI Heating", "Thorn EMI Heating", "Housewarmer", "spectaculardeluxe", "4478925", "", "1990", "1", "4", "0", "1", "0", "", "", "1", "1", "1", "", "", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1538, "brand_name": "Thorn EMI Heating", "model_name": "Housewarmer", "model_qualifier": "spectaculars", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": null, "final_year_of_manufacture": 1988, "raw": ["001538", "000005", "0", "2010/Sep/13 17:03", "Thorn EMI Heating", "Thorn EMI Heating", "Housewarmer", "spectaculars", "4478924", "", "1988", "1", "4", "0", "1", "0", "", "", "1", "1", "1", "", "", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1539, "brand_name": "Thorn EMI Heating", "model_name": "Housewarmer", "model_qualifier": "super", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": null, "final_year_of_manufacture": 1981, "raw": ["001539", "000005", "0", "2010/Sep/13 17:03", "Thorn EMI Heating", "Thorn EMI Heating", "Housewarmer", "super", "4478908", "", "1981", "1", "4", "0", "1", "0", "", "", "1", "1", "1", "", "", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1540, "brand_name": "Thorn EMI Heating", "model_name": "Housewarmer 2", "model_qualifier": "30/45deluxe", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": null, "final_year_of_manufacture": 1983, "raw": ["001540", "000005", "0", "2010/Sep/13 17:03", "Thorn EMI Heating", "Thorn EMI Heating", "Housewarmer 2", "30/45deluxe", "4478913", "", "1983", "1", "4", "0", "1", "0", "", "", "1", "1", "1", "", "", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1541, "brand_name": "Thorn EMI Heating", "model_name": "Housewarmer 2", "model_qualifier": "30/45e", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": null, "final_year_of_manufacture": 1983, "raw": ["001541", "000005", "0", "2010/Sep/13 17:03", "Thorn EMI Heating", "Thorn EMI Heating", "Housewarmer 2", "30/45e", "4478910", "", "1983", "1", "4", "0", "1", "0", "", "", "1", "1", "1", "", "", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1542, "brand_name": "Thorn EMI Heating", "model_name": "Housewarmer 2", "model_qualifier": "30/45eplus", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": null, "final_year_of_manufacture": 1983, "raw": ["001542", "000005", "0", "2010/Sep/13 17:03", "Thorn EMI Heating", "Thorn EMI Heating", "Housewarmer 2", "30/45eplus", "4478914", "", "1983", "1", "4", "0", "1", "0", "", "", "1", "1", "1", "", "", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1543, "brand_name": "Thorn EMI Heating", "model_name": "Housewarmer 2", "model_qualifier": "30/45s", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": null, "final_year_of_manufacture": 1983, "raw": ["001543", "000005", "0", "2010/Sep/13 17:03", "Thorn EMI Heating", "Thorn EMI Heating", "Housewarmer 2", "30/45s", "4478911", "", "1983", "1", "4", "0", "1", "0", "", "", "1", "1", "1", "", "", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1544, "brand_name": "Thorn EMI Heating", "model_name": "Housewarmer 2", "model_qualifier": "30/45super", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": null, "final_year_of_manufacture": 1983, "raw": ["001544", "000005", "0", "2010/Sep/13 17:03", "Thorn EMI Heating", "Thorn EMI Heating", "Housewarmer 2", "30/45super", "4478912", "", "1983", "1", "4", "0", "1", "0", "", "", "1", "1", "1", "", "", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1545, "brand_name": "Thorn EMI Heating", "model_name": "Housewarmer Mk2", "model_qualifier": "30/45extra", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": null, "final_year_of_manufacture": 1985, "raw": ["001545", "000005", "0", "2010/Sep/13 17:03", "Thorn EMI Heating", "Thorn EMI Heating", "Housewarmer Mk2", "30/45extra", "4478921", "", "1985", "1", "4", "0", "1", "0", "", "", "1", "1", "1", "", "", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1546, "brand_name": "Thorn EMI Heating", "model_name": "International", "model_qualifier": "40deluxe", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": null, "final_year_of_manufacture": 1972, "raw": ["001546", "000005", "0", "2010/Sep/13 17:03", "Thorn EMI Heating", "Thorn EMI Heating", "International", "40deluxe", "4441101", "", "1972", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "", "", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1547, "brand_name": "Thorn EMI Heating", "model_name": "Marathon", "model_qualifier": "1000b", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 27.0, "final_year_of_manufacture": 1997, "raw": ["001547", "000005", "0", "2010/Sep/13 17:03", "Thorn EMI Heating", "Thorn EMI Heating", "Marathon", "1000b", "4149413", "", "1997", "1", "1", "1", "1", "0", "", "", "1", "2", "1", "27", "27", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "1", "20", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1548, "brand_name": "Thorn EMI Heating", "model_name": "Marathon", "model_qualifier": "1000c", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 27.8, "final_year_of_manufacture": 1997, "raw": ["001548", "000005", "0", "2010/Sep/13 17:03", "Thorn EMI Heating", "Thorn EMI Heating", "Marathon", "1000c", "4149419", "", "1997", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "27.8", "27.8", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "1", "20", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1549, "brand_name": "Thorn EMI Heating", "model_name": "Marathon", "model_qualifier": "1500c", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 41.47, "final_year_of_manufacture": 1997, "raw": ["001549", "000005", "0", "2010/Sep/13 17:03", "Thorn EMI Heating", "Thorn EMI Heating", "Marathon", "1500c", "4149420", "", "1997", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "41.47", "41.47", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "1", "20", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1550, "brand_name": "Thorn EMI Heating", "model_name": "Marathon", "model_qualifier": "400b", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 11.7, "final_year_of_manufacture": 1997, "raw": ["001550", "000005", "0", "2010/Sep/13 17:03", "Thorn EMI Heating", "Thorn EMI Heating", "Marathon", "400b", "4149408", "", "1997", "1", "1", "1", "1", "0", "", "", "1", "2", "1", "8.8", "11.7", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "1", "20", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1551, "brand_name": "Thorn EMI Heating", "model_name": "Marathon", "model_qualifier": "400c", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 11.7, "final_year_of_manufacture": 1997, "raw": ["001551", "000005", "0", "2010/Sep/13 17:03", "Thorn EMI Heating", "Thorn EMI Heating", "Marathon", "400c", "4149414", "", "1997", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "8.8", "11.7", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "1", "20", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1552, "brand_name": "Thorn EMI Heating", "model_name": "Marathon", "model_qualifier": "500b", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 14.7, "final_year_of_manufacture": 1997, "raw": ["001552", "000005", "0", "2010/Sep/13 17:03", "Thorn EMI Heating", "Thorn EMI Heating", "Marathon", "500b", "4149409", "", "1997", "1", "1", "1", "1", "0", "", "", "1", "2", "1", "11.7", "14.7", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "1", "20", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1553, "brand_name": "Thorn EMI Heating", "model_name": "Marathon", "model_qualifier": "500c", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 14.7, "final_year_of_manufacture": 1997, "raw": ["001553", "000005", "0", "2010/Sep/13 17:03", "Thorn EMI Heating", "Thorn EMI Heating", "Marathon", "500c", "4149415", "", "1997", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "11.7", "14.7", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "1", "20", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1554, "brand_name": "Thorn EMI Heating", "model_name": "Marathon", "model_qualifier": "600b", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 17.6, "final_year_of_manufacture": 1997, "raw": ["001554", "000005", "0", "2010/Sep/13 17:03", "Thorn EMI Heating", "Thorn EMI Heating", "Marathon", "600b", "4149410", "", "1997", "1", "1", "1", "1", "0", "", "", "1", "2", "1", "14.7", "17.6", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "1", "20", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1555, "brand_name": "Thorn EMI Heating", "model_name": "Marathon", "model_qualifier": "600c", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 17.6, "final_year_of_manufacture": 1997, "raw": ["001555", "000005", "0", "2010/Sep/13 17:03", "Thorn EMI Heating", "Thorn EMI Heating", "Marathon", "600c", "4149416", "", "1997", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "14.7", "17.6", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "1", "20", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1556, "brand_name": "Thorn EMI Heating", "model_name": "Marathon", "model_qualifier": "700b", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 20.5, "final_year_of_manufacture": 1997, "raw": ["001556", "000005", "0", "2010/Sep/13 17:03", "Thorn EMI Heating", "Thorn EMI Heating", "Marathon", "700b", "4149411", "", "1997", "1", "1", "1", "1", "0", "", "", "1", "2", "1", "17.6", "20.5", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "1", "20", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1557, "brand_name": "Thorn EMI Heating", "model_name": "Marathon", "model_qualifier": "700c", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 20.5, "final_year_of_manufacture": null, "raw": ["001557", "000005", "0", "2010/Sep/13 17:03", "Thorn EMI Heating", "Thorn EMI Heating", "Marathon", "700c", "4149417", "", "obsolete", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "17.6", "20.5", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1558, "brand_name": "Thorn EMI Heating", "model_name": "Marathon", "model_qualifier": "800b", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 23.5, "final_year_of_manufacture": 1997, "raw": ["001558", "000005", "0", "2010/Sep/13 17:03", "Thorn EMI Heating", "Thorn EMI Heating", "Marathon", "800b", "4149412", "", "1997", "1", "1", "1", "1", "0", "", "", "1", "2", "1", "20.5", "23.5", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "1", "20", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1559, "brand_name": "Thorn EMI Heating", "model_name": "Marathon", "model_qualifier": "800c", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 23.5, "final_year_of_manufacture": 1997, "raw": ["001559", "000005", "0", "2010/Sep/13 17:03", "Thorn EMI Heating", "Thorn EMI Heating", "Marathon", "800c", "4149418", "", "1997", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "20.5", "23.5", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "1", "20", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1560, "brand_name": "Potterton Myson Heating", "model_name": "Wilson", "model_qualifier": "ga40bf", "winter_efficiency_pct": 56.0, "summer_efficiency_pct": 46.0, "comparative_hot_water_efficiency_pct": 33.5, "output_kw_max": 10.7, "final_year_of_manufacture": 1975, "raw": ["001560", "000005", "0", "2010/Sep/13 17:03", "Potterton Myson Heating", "Potterton Myson Heating", "Wilson", "ga40bf", "4183841", "", "1975", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "10.7", "10.7", "", "", "56.0", "46.0", "", "33.5", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1561, "brand_name": "Potterton Myson Heating", "model_name": "Wilson", "model_qualifier": "ga40cf", "winter_efficiency_pct": 56.0, "summer_efficiency_pct": 46.0, "comparative_hot_water_efficiency_pct": 33.5, "output_kw_max": 10.7, "final_year_of_manufacture": 1975, "raw": ["001561", "000005", "0", "2010/Sep/13 17:03", "Potterton Myson Heating", "Potterton Myson Heating", "Wilson", "ga40cf", "4183840", "", "1975", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "10.7", "10.7", "", "", "56.0", "46.0", "", "33.5", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1562, "brand_name": "Potterton Myson Heating", "model_name": "Wilson", "model_qualifier": "ga53bf", "winter_efficiency_pct": 56.0, "summer_efficiency_pct": 46.0, "comparative_hot_water_efficiency_pct": 33.5, "output_kw_max": 14.35, "final_year_of_manufacture": 1975, "raw": ["001562", "000005", "0", "2010/Sep/13 17:03", "Potterton Myson Heating", "Potterton Myson Heating", "Wilson", "ga53bf", "4183843", "", "1975", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "14.35", "14.35", "", "", "56.0", "46.0", "", "33.5", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1563, "brand_name": "Potterton Myson Heating", "model_name": "Wilson", "model_qualifier": "ga53cf", "winter_efficiency_pct": 56.0, "summer_efficiency_pct": 46.0, "comparative_hot_water_efficiency_pct": 33.5, "output_kw_max": 14.35, "final_year_of_manufacture": 1975, "raw": ["001563", "000005", "0", "2010/Sep/13 17:03", "Potterton Myson Heating", "Potterton Myson Heating", "Wilson", "ga53cf", "4183842", "", "1975", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "14.35", "14.35", "", "", "56.0", "46.0", "", "33.5", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1564, "brand_name": "Potterton Myson Heating", "model_name": "Wilson", "model_qualifier": "ga70bf", "winter_efficiency_pct": 56.0, "summer_efficiency_pct": 46.0, "comparative_hot_water_efficiency_pct": 33.5, "output_kw_max": 19.7, "final_year_of_manufacture": 1975, "raw": ["001564", "000005", "0", "2010/Sep/13 17:03", "Potterton Myson Heating", "Potterton Myson Heating", "Wilson", "ga70bf", "4183845", "", "1975", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "19.7", "19.7", "", "", "56.0", "46.0", "", "33.5", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1565, "brand_name": "Potterton Myson Heating", "model_name": "Wilson", "model_qualifier": "ga70cf", "winter_efficiency_pct": 56.0, "summer_efficiency_pct": 46.0, "comparative_hot_water_efficiency_pct": 33.5, "output_kw_max": 19.7, "final_year_of_manufacture": 1975, "raw": ["001565", "000005", "0", "2010/Sep/13 17:03", "Potterton Myson Heating", "Potterton Myson Heating", "Wilson", "ga70cf", "4183844", "", "1975", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "19.7", "19.7", "", "", "56.0", "46.0", "", "33.5", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1568, "brand_name": "Oceanspa", "model_name": "Ocean", "model_qualifier": "80ff", "winter_efficiency_pct": 71.0, "summer_efficiency_pct": 62.0, "comparative_hot_water_efficiency_pct": 43.2, "output_kw_max": 23.4, "final_year_of_manufacture": 1995, "raw": ["001568", "000083", "0", "2010/Sep/13 17:03", "Oceanspa", "Oceanspa", "Ocean", "80ff", "4753201", "", "1995", "1", "0", "0", "2", "0", "", "", "1", "2", "2", "23.4", "23.4", "", "", "71.0", "62.0", "", "43.2", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1569, "brand_name": "Oceanspa", "model_name": "Ocean", "model_qualifier": "80ffstyle", "winter_efficiency_pct": 71.0, "summer_efficiency_pct": 62.0, "comparative_hot_water_efficiency_pct": 43.2, "output_kw_max": 17.6, "final_year_of_manufacture": 1995, "raw": ["001569", "000083", "0", "2010/Sep/13 17:03", "Oceanspa", "Oceanspa", "Ocean", "80ffstyle", "4753202", "", "1995", "1", "0", "0", "2", "0", "", "", "1", "2", "2", "17.6", "17.6", "", "", "71.0", "62.0", "", "43.2", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1570, "brand_name": "Oceanspa", "model_name": "Ocean", "model_qualifier": "80ofstyle", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 57.0, "comparative_hot_water_efficiency_pct": 39.7, "output_kw_max": 17.6, "final_year_of_manufacture": 1995, "raw": ["001570", "000083", "0", "2010/Sep/13 17:03", "Oceanspa", "Oceanspa", "Ocean", "80ofstyle", "4735203", "", "1995", "1", "0", "0", "2", "0", "", "", "1", "1", "1", "17.6", "17.6", "", "", "66.0", "57.0", "", "39.7", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1571, "brand_name": "Parkray", "model_name": "Parkray", "model_qualifier": "401", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": null, "final_year_of_manufacture": null, "raw": ["001571", "000020", "0", "2010/Sep/13 17:03", "Parkray", "Parkray", "Parkray", "401", "4462001", "", "obsolete", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "", "", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1572, "brand_name": "Parkray", "model_name": "Parkray", "model_qualifier": "402", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": null, "final_year_of_manufacture": null, "raw": ["001572", "000020", "0", "2010/Sep/13 17:03", "Parkray", "Parkray", "Parkray", "402", "4462003", "", "obsolete", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "", "", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1573, "brand_name": "Parkray", "model_name": "Parkray", "model_qualifier": "404", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": null, "final_year_of_manufacture": null, "raw": ["001573", "000020", "0", "2010/Sep/13 17:03", "Parkray", "Parkray", "Parkray", "404", "4462002", "", "obsolete", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "", "", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1574, "brand_name": "Powermatic", "model_name": "Sgm", "model_qualifier": "3gb", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 17.59, "final_year_of_manufacture": 1988, "raw": ["001574", "000085", "0", "2010/Sep/13 17:03", "Powermatic", "Powermatic", "Sgm", "3gb", "4128301", "", "1988", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "17.59", "17.59", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1575, "brand_name": "Powermatic", "model_name": "Sgm", "model_qualifier": "4gb", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 26.39, "final_year_of_manufacture": 1988, "raw": ["001575", "000085", "0", "2010/Sep/13 17:03", "Powermatic", "Powermatic", "Sgm", "4gb", "4128302", "", "1988", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "26.39", "26.39", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1581, "brand_name": "R H Ingham", "model_name": "Ingham Danesmoor", "model_qualifier": "42", "winter_efficiency_pct": 65.0, "summer_efficiency_pct": 53.0, "comparative_hot_water_efficiency_pct": 38.9, "output_kw_max": 12.3, "final_year_of_manufacture": null, "raw": ["001581", "000035", "0", "2010/Sep/13 17:03", "R H Ingham", "R H Ingham", "Ingham Danesmoor", "42", "", "", "obsolete", "4", "1", "1", "1", "0", "", "", "1", "1", "1", "12.3", "12.3", "", "", "65.0", "53.0", "", "38.9", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1582, "brand_name": "R H Ingham", "model_name": "Ingham Danesmoor", "model_qualifier": "60", "winter_efficiency_pct": 65.0, "summer_efficiency_pct": 53.0, "comparative_hot_water_efficiency_pct": 38.9, "output_kw_max": 17.6, "final_year_of_manufacture": null, "raw": ["001582", "000035", "0", "2010/Sep/13 17:03", "R H Ingham", "R H Ingham", "Ingham Danesmoor", "60", "", "", "obsolete", "4", "1", "1", "1", "0", "", "", "1", "1", "1", "17.6", "17.6", "", "", "65.0", "53.0", "", "38.9", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1583, "brand_name": "R H Ingham", "model_name": "Ingham Danesmoor", "model_qualifier": "80", "winter_efficiency_pct": 65.0, "summer_efficiency_pct": 53.0, "comparative_hot_water_efficiency_pct": 38.9, "output_kw_max": 23.4, "final_year_of_manufacture": null, "raw": ["001583", "000035", "0", "2010/Sep/13 17:03", "R H Ingham", "R H Ingham", "Ingham Danesmoor", "80", "", "", "obsolete", "4", "1", "1", "1", "0", "", "", "1", "1", "1", "23.4", "23.4", "", "", "65.0", "53.0", "", "38.9", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1584, "brand_name": "R H Ingham", "model_name": "Ingham Danesmoor", "model_qualifier": "ABK 60/100", "winter_efficiency_pct": 65.0, "summer_efficiency_pct": 53.0, "comparative_hot_water_efficiency_pct": 38.9, "output_kw_max": 17.6, "final_year_of_manufacture": null, "raw": ["001584", "000035", "0", "2010/Sep/13 17:03", "R H Ingham", "R H Ingham", "Ingham Danesmoor", "ABK 60/100", "", "", "obsolete", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "17.6", "17.6", "", "", "65.0", "53.0", "", "38.9", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1585, "brand_name": "R H Ingham", "model_name": "Ingham Danesmoor", "model_qualifier": "PJ20/30", "winter_efficiency_pct": 65.0, "summer_efficiency_pct": 53.0, "comparative_hot_water_efficiency_pct": 38.9, "output_kw_max": 22.0, "final_year_of_manufacture": null, "raw": ["001585", "000035", "0", "2010/Sep/13 17:03", "R H Ingham", "R H Ingham", "Ingham Danesmoor", "PJ20/30", "", "", "obsolete", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "22", "22", "", "", "65.0", "53.0", "", "38.9", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1586, "brand_name": "R H Ingham", "model_name": "Ingham Danesmoor", "model_qualifier": "PJ 20/30", "winter_efficiency_pct": 65.0, "summer_efficiency_pct": 53.0, "comparative_hot_water_efficiency_pct": 38.9, "output_kw_max": 26.4, "final_year_of_manufacture": null, "raw": ["001586", "000035", "0", "2010/Sep/13 17:03", "R H Ingham", "R H Ingham", "Ingham Danesmoor", "PJ 20/30", "", "", "obsolete", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "26.4", "26.4", "", "", "65.0", "53.0", "", "38.9", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1588, "brand_name": "R H Ingham", "model_name": "Ingham Danesmoor", "model_qualifier": "PJ 30/45", "winter_efficiency_pct": 65.0, "summer_efficiency_pct": 53.0, "comparative_hot_water_efficiency_pct": 38.9, "output_kw_max": 35.2, "final_year_of_manufacture": null, "raw": ["001588", "000035", "0", "2010/Sep/13 17:03", "R H Ingham", "R H Ingham", "Ingham Danesmoor", "PJ 30/45", "", "", "obsolete", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "29.3", "35.2", "", "", "65.0", "53.0", "", "38.9", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1603, "brand_name": "Trianco", "model_name": "Centramatic M", "model_qualifier": "", "winter_efficiency_pct": 65.0, "summer_efficiency_pct": 53.0, "comparative_hot_water_efficiency_pct": 38.9, "output_kw_max": 12.3, "final_year_of_manufacture": null, "raw": ["001603", "000062", "0", "2010/Sep/13 17:03", "Trianco Redfyre", "Trianco", "Centramatic M", "", "", "", "obsolete", "4", "0", "0", "1", "0", "", "", "1", "1", "1", "12.3", "12.3", "", "", "65.0", "53.0", "", "38.9", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1604, "brand_name": "Trianco", "model_name": "Centramatic", "model_qualifier": "40", "winter_efficiency_pct": 65.0, "summer_efficiency_pct": 53.0, "comparative_hot_water_efficiency_pct": 38.9, "output_kw_max": 12.3, "final_year_of_manufacture": null, "raw": ["001604", "000062", "0", "2010/Sep/13 17:03", "Trianco Redfyre", "Trianco", "Centramatic", "40", "", "", "obsolete", "4", "0", "0", "1", "0", "", "", "1", "1", "1", "12.3", "12.3", "", "", "65.0", "53.0", "", "38.9", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1605, "brand_name": "Trianco", "model_name": "Centramatic", "model_qualifier": "55", "winter_efficiency_pct": 65.0, "summer_efficiency_pct": 53.0, "comparative_hot_water_efficiency_pct": 38.9, "output_kw_max": 16.4, "final_year_of_manufacture": null, "raw": ["001605", "000062", "0", "2010/Sep/13 17:03", "Trianco Redfyre", "Trianco", "Centramatic", "55", "", "", "obsolete", "4", "0", "0", "1", "0", "", "", "1", "1", "1", "16.4", "16.4", "", "", "65.0", "53.0", "", "38.9", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1606, "brand_name": "Trianco", "model_name": "Centramatic", "model_qualifier": "80", "winter_efficiency_pct": 65.0, "summer_efficiency_pct": 53.0, "comparative_hot_water_efficiency_pct": 38.9, "output_kw_max": 23.4, "final_year_of_manufacture": null, "raw": ["001606", "000062", "0", "2010/Sep/13 17:03", "Trianco Redfyre", "Trianco", "Centramatic", "80", "", "", "obsolete", "4", "0", "0", "1", "0", "", "", "1", "1", "1", "23.4", "23.4", "", "", "65.0", "53.0", "", "38.9", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1609, "brand_name": "Trianco", "model_name": "Centrajet", "model_qualifier": "18/28", "winter_efficiency_pct": 65.0, "summer_efficiency_pct": 53.0, "comparative_hot_water_efficiency_pct": 38.9, "output_kw_max": 28.0, "final_year_of_manufacture": null, "raw": ["001609", "000062", "0", "2010/Sep/13 17:03", "Trianco Redfyre", "Trianco", "Centrajet", "18/28", "", "", "obsolete", "4", "0", "0", "1", "0", "", "", "1", "2", "2", "18", "28", "", "", "65.0", "53.0", "", "38.9", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1622, "brand_name": "Trisave", "model_name": "Fs", "model_qualifier": "43435", "winter_efficiency_pct": 91.0, "summer_efficiency_pct": 74.0, "comparative_hot_water_efficiency_pct": 53.7, "output_kw_max": 17.7, "final_year_of_manufacture": 1994, "raw": ["001622", "000139", "0", "2010/Sep/13 17:03", "Trisave", "Trisave", "Fs", "43435", "4115902", "", "1994", "1", "0", "0", "1", "0", "", "", "2", "2", "2", "17.7", "17.7", "", "", "91.0", "74.0", "", "53.7", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0001", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1623, "brand_name": "Trisave", "model_name": "Fs", "model_qualifier": "18-24", "winter_efficiency_pct": 91.0, "summer_efficiency_pct": 74.0, "comparative_hot_water_efficiency_pct": 53.7, "output_kw_max": 23.3, "final_year_of_manufacture": 1991, "raw": ["001623", "000139", "0", "2010/Sep/13 17:03", "Trisave", "Trisave", "Fs", "18-24", "4115901", "", "1991", "1", "0", "0", "1", "0", "", "", "2", "2", "2", "23.3", "23.3", "", "", "91.0", "74.0", "", "53.7", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0001", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1624, "brand_name": "Trisave", "model_name": "Fs", "model_qualifier": "60", "winter_efficiency_pct": 91.0, "summer_efficiency_pct": 74.0, "comparative_hot_water_efficiency_pct": 53.7, "output_kw_max": 17.6, "final_year_of_manufacture": 1991, "raw": ["001624", "000139", "0", "2010/Sep/13 17:03", "Trisave", "Trisave", "Fs", "60", "4115905", "", "1991", "1", "0", "0", "1", "0", "", "", "2", "2", "2", "17.6", "17.6", "", "", "91.0", "74.0", "", "53.7", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0001", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1625, "brand_name": "Trisave", "model_name": "Fs", "model_qualifier": "80", "winter_efficiency_pct": 91.0, "summer_efficiency_pct": 74.0, "comparative_hot_water_efficiency_pct": 53.7, "output_kw_max": 24.5, "final_year_of_manufacture": null, "raw": ["001625", "000139", "0", "2010/Sep/13 17:03", "Trisave", "Trisave", "Fs", "80", "4115912", "", "obsolete", "1", "0", "0", "1", "0", "", "", "2", "2", "2", "24.5", "24.5", "", "", "91.0", "74.0", "", "53.7", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0001", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1626, "brand_name": "Trisave", "model_name": "Turbo", "model_qualifier": "22", "winter_efficiency_pct": 91.0, "summer_efficiency_pct": 74.0, "comparative_hot_water_efficiency_pct": 53.7, "output_kw_max": 5.7, "final_year_of_manufacture": 1991, "raw": ["001626", "000139", "0", "2010/Sep/13 17:03", "Trisave", "Trisave", "Turbo", "22", "4115906", "", "1991", "1", "0", "0", "1", "0", "", "", "2", "2", "2", "5.7", "5.7", "", "", "91.0", "74.0", "", "53.7", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0001", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1627, "brand_name": "Trisave", "model_name": "Turbo", "model_qualifier": "30", "winter_efficiency_pct": 91.0, "summer_efficiency_pct": 74.0, "comparative_hot_water_efficiency_pct": 53.7, "output_kw_max": 8.5, "final_year_of_manufacture": 1994, "raw": ["001627", "000139", "0", "2010/Sep/13 17:03", "Trisave", "Trisave", "Turbo", "30", "4115907", "", "1994", "1", "0", "0", "1", "0", "", "", "2", "2", "2", "8.5", "8.5", "", "", "91.0", "74.0", "", "53.7", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0001", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1628, "brand_name": "Trisave", "model_name": "Turbo", "model_qualifier": "45", "winter_efficiency_pct": 91.0, "summer_efficiency_pct": 74.0, "comparative_hot_water_efficiency_pct": 53.7, "output_kw_max": 13.2, "final_year_of_manufacture": 1994, "raw": ["001628", "000139", "0", "2010/Sep/13 17:03", "Trisave", "Trisave", "Turbo", "45", "4115903", "", "1994", "1", "0", "0", "1", "0", "", "", "2", "2", "2", "13.2", "13.2", "", "", "91.0", "74.0", "", "53.7", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0001", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1629, "brand_name": "Trisave", "model_name": "Turbo", "model_qualifier": "60", "winter_efficiency_pct": 91.0, "summer_efficiency_pct": 74.0, "comparative_hot_water_efficiency_pct": 53.7, "output_kw_max": 17.6, "final_year_of_manufacture": 1994, "raw": ["001629", "000139", "0", "2010/Sep/13 17:03", "Trisave", "Trisave", "Turbo", "60", "4115904", "", "1994", "1", "0", "0", "1", "0", "", "", "2", "2", "2", "17.6", "17.6", "", "", "91.0", "74.0", "", "53.7", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0001", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1630, "brand_name": "Wickes", "model_name": "Wickes", "model_qualifier": "40bf", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 11.72, "final_year_of_manufacture": 1996, "raw": ["001630", "000019", "0", "2010/Sep/13 17:03", "Wickes", "Wickes", "Wickes", "40bf", "4133322", "", "1996", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "11.72", "11.72", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1631, "brand_name": "Wickes", "model_name": "Wickes", "model_qualifier": "45f", "winter_efficiency_pct": 73.0, "summer_efficiency_pct": 63.0, "comparative_hot_water_efficiency_pct": 45.9, "output_kw_max": 13.19, "final_year_of_manufacture": 1997, "raw": ["001631", "000019", "0", "2015/Jul/21 14:15", "Wickes", "Wickes", "Wickes", "45f", "4133311", "", "1997", "1", "0", "0", "1", "0", "", "", "1", "2", "2", "13.19", "13.19", "", "", "73.0", "63.0", "", "45.9", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1632, "brand_name": "Wickes", "model_name": "Wickes", "model_qualifier": "50bf", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 14.65, "final_year_of_manufacture": 1994, "raw": ["001632", "000019", "0", "2010/Sep/13 17:03", "Wickes", "Wickes", "Wickes", "50bf", "4133323", "", "1994", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "14.65", "14.65", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1633, "brand_name": "Wickes", "model_name": "Wickes", "model_qualifier": "65f", "winter_efficiency_pct": 73.0, "summer_efficiency_pct": 63.0, "comparative_hot_water_efficiency_pct": 45.9, "output_kw_max": 19.05, "final_year_of_manufacture": 1997, "raw": ["001633", "000019", "0", "2015/Jul/21 14:15", "Wickes", "Wickes", "Wickes", "65f", "4133312", "", "1997", "1", "0", "0", "1", "0", "", "", "1", "2", "2", "19.05", "19.05", "", "", "73.0", "63.0", "", "45.9", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1634, "brand_name": "Wickes", "model_name": "Wickes", "model_qualifier": "combi", "winter_efficiency_pct": 71.0, "summer_efficiency_pct": 62.0, "comparative_hot_water_efficiency_pct": 43.2, "output_kw_max": 23.63, "final_year_of_manufacture": 1992, "raw": ["001634", "000019", "0", "2010/Sep/13 17:03", "Wickes", "Wickes", "Wickes", "combi", "4770502", "", "1992", "1", "0", "0", "2", "0", "", "", "1", "2", "2", "23.63", "23.63", "", "", "71.0", "62.0", "", "43.2", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 1636, "brand_name": "Malvern", "model_name": "Combi", "model_qualifier": "NG", "winter_efficiency_pct": 84.6, "summer_efficiency_pct": 76.0, "comparative_hot_water_efficiency_pct": 53.5, "output_kw_max": 23.5, "final_year_of_manufacture": null, "raw": ["001636", "000023", "0", "2006/Jan/17 12:31", "Malvern Boilers", "Malvern", "Combi", "NG", "GC No 47.555.02", "1995", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "23.5", "23.5", "", "", "84.6", "76.0", "", "53.5", "", "2", "", "", "104", "1", "2", "120", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "86.1", "89.0", "", "", "", "", "88.5"]} -{"pcdb_id": 1638, "brand_name": "Malvern", "model_name": "70/80", "model_qualifier": "NG", "winter_efficiency_pct": 82.9, "summer_efficiency_pct": 75.3, "comparative_hot_water_efficiency_pct": 55.0, "output_kw_max": 23.5, "final_year_of_manufacture": 2000, "raw": ["001638", "000023", "0", "2012/Mar/27 10:12", "Malvern Boilers", "Malvern", "70/80", "NG", "GC No 41.555.10", "1995", "2000", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "20.6", "23.5", "", "", "82.9", "75.3", "", "55.0", "", "2", "", "", "101", "1", "1", "40", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "85.7", "88.7", "", "", "", "", "88.2"]} -{"pcdb_id": 1647, "brand_name": "Malvern", "model_name": "50", "model_qualifier": "NG", "winter_efficiency_pct": 83.2, "summer_efficiency_pct": 75.6, "comparative_hot_water_efficiency_pct": 55.2, "output_kw_max": 14.7, "final_year_of_manufacture": 2000, "raw": ["001647", "000023", "0", "2012/Mar/27 10:12", "Malvern Boilers", "Malvern", "50", "NG", "GC No 41.555.01", "1993", "2000", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "14.7", "14.7", "", "", "83.2", "75.6", "", "55.2", "", "2", "", "", "101", "1", "1", "40", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "85.7", "89.5", "", "", "", "", "88.8"]} -{"pcdb_id": 1648, "brand_name": "Malvern", "model_name": "40", "model_qualifier": "NG", "winter_efficiency_pct": 82.6, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 11.7, "final_year_of_manufacture": 2000, "raw": ["001648", "000023", "0", "2012/Mar/27 10:12", "Malvern Boilers", "Malvern", "40", "NG", "GC No 41.555.03", "1993", "2000", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "11.7", "11.7", "", "", "82.6", "75.0", "", "54.8", "", "2", "", "", "101", "1", "1", "40", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "85.0", "88.7", "", "", "", "", "88.0"]} -{"pcdb_id": 1649, "brand_name": "Malvern", "model_name": "30", "model_qualifier": "NG", "winter_efficiency_pct": 82.2, "summer_efficiency_pct": 74.6, "comparative_hot_water_efficiency_pct": 54.5, "output_kw_max": 8.8, "final_year_of_manufacture": 2000, "raw": ["001649", "000023", "0", "2012/Mar/27 10:12", "Malvern Boilers", "Malvern", "30", "NG", "GC No 41.555.02", "1993", "2000", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "8.8", "8.8", "", "", "82.2", "74.6", "", "54.5", "", "2", "", "", "101", "1", "1", "40", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "84.2", "88.7", "", "", "", "", "87.9"]} -{"pcdb_id": 1650, "brand_name": "Alpha", "model_name": "280P", "model_qualifier": "", "winter_efficiency_pct": 75.8, "summer_efficiency_pct": 65.7, "comparative_hot_water_efficiency_pct": 46.2, "output_kw_max": 28.0, "final_year_of_manufacture": 2003, "raw": ["001650", "000001", "0", "2006/Jan/17 12:55", "Alpha Therm", "Alpha", "280P", "", "", "1998", "2003", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "28", "28", "", "", "75.8", "65.7", "", "46.2", "", "2", "", "", "104", "2", "2", "170", "5", "0", "", "", "0", "0", "0", "", "0", "0", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.4", "80.5", "", "", "", "", "80.7"]} -{"pcdb_id": 1652, "brand_name": "Alpha", "model_name": "500E", "model_qualifier": "", "winter_efficiency_pct": 79.4, "summer_efficiency_pct": 70.3, "comparative_hot_water_efficiency_pct": 50.1, "output_kw_max": 28.0, "final_year_of_manufacture": 2003, "raw": ["001652", "000001", "0", "2024/Jan/31 10:17", "Alpha Therm", "Alpha", "500E", "", "", "1996", "2003", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "28", "28", "", "", "79.4", "70.3", "", "50.1", "", "2", "", "", "106", "1", "2", "182", "5", "2", "2", "0", "54", "0", "50", "5", "65", "0.96", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.4", "79.1", "", "", "", "", "79.5"]} -{"pcdb_id": 1653, "brand_name": "Alpha", "model_name": "240X", "model_qualifier": "", "winter_efficiency_pct": 75.2, "summer_efficiency_pct": 65.1, "comparative_hot_water_efficiency_pct": 45.8, "output_kw_max": 23.3, "final_year_of_manufacture": 2003, "raw": ["001653", "000001", "0", "2006/Jan/17 12:55", "Alpha Therm", "Alpha", "240X", "", "", "1998", "2003", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "23.3", "23.3", "", "", "75.2", "65.1", "", "45.8", "", "2", "", "", "104", "2", "2", "170", "20", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.7", "79.1", "", "", "", "", "79.6"]} -{"pcdb_id": 1658, "brand_name": "Keston", "model_name": "K", "model_qualifier": "50", "winter_efficiency_pct": 85.6, "summer_efficiency_pct": 78.0, "comparative_hot_water_efficiency_pct": 57.0, "output_kw_max": 15.2, "final_year_of_manufacture": null, "raw": ["001658", "000022", "0", "2012/Mar/27 10:12", "Keston Boilers", "Keston", "K", "50", "Keston 50", "1994", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "14.1", "15.2", "", "", "85.6", "78.0", "", "57.0", "", "2", "", "", "101", "1", "1", "140", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "88.3", "94.1", "", "", "", "", "93.0"]} -{"pcdb_id": 1659, "brand_name": "Keston", "model_name": "K", "model_qualifier": "50P", "winter_efficiency_pct": 87.3, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 16.0, "final_year_of_manufacture": null, "raw": ["001659", "000022", "0", "2012/Mar/27 10:12", "Keston Boilers", "Keston", "K", "50P", "Keston 50 LPG", "1994", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "14.5", "16.0", "", "", "87.3", "79.7", "", "58.2", "", "2", "0", "", "101", "1", "1", "140", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "88.4", "96.2", "", "", "", "", "94.7"]} -{"pcdb_id": 1660, "brand_name": "Keston", "model_name": "K", "model_qualifier": "60", "winter_efficiency_pct": 85.7, "summer_efficiency_pct": 78.1, "comparative_hot_water_efficiency_pct": 57.1, "output_kw_max": 17.7, "final_year_of_manufacture": null, "raw": ["001660", "000022", "0", "2012/Mar/27 10:12", "Keston Boilers", "Keston", "K", "60", "Keston 60", "1994", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "16.2", "17.7", "", "", "85.7", "78.1", "", "57.1", "", "2", "", "", "101", "1", "1", "140", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "87.9", "94.6", "", "", "", "", "93.3"]} -{"pcdb_id": 1661, "brand_name": "Keston", "model_name": "K", "model_qualifier": "60P", "winter_efficiency_pct": 87.5, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 24.5, "final_year_of_manufacture": null, "raw": ["001661", "000022", "0", "2012/Mar/27 10:12", "Keston Boilers", "Keston", "K", "60P", "Keston 60 LPG", "1994", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "22.6", "24.5", "", "", "87.5", "79.9", "", "58.3", "", "2", "0", "", "101", "1", "1", "175", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "88.2", "96.7", "", "", "", "", "95.1"]} -{"pcdb_id": 1662, "brand_name": "Keston", "model_name": "K", "model_qualifier": "80", "winter_efficiency_pct": 85.8, "summer_efficiency_pct": 78.2, "comparative_hot_water_efficiency_pct": 57.2, "output_kw_max": 23.7, "final_year_of_manufacture": null, "raw": ["001662", "000022", "0", "2012/Mar/27 10:12", "Keston Boilers", "Keston", "K", "80", "Keston 80", "1994", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "21.4", "23.7", "", "", "85.8", "78.2", "", "57.2", "", "2", "", "", "101", "1", "1", "175", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "86.5", "95.5", "", "", "", "", "93.8"]} -{"pcdb_id": 1663, "brand_name": "Keston", "model_name": "K", "model_qualifier": "80P", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 80.6, "comparative_hot_water_efficiency_pct": 58.9, "output_kw_max": 24.5, "final_year_of_manufacture": null, "raw": ["001663", "000022", "0", "2012/Mar/27 10:12", "Keston Boilers", "Keston", "K", "80P", "Keston 80 LPG", "1994", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "22.6", "24.5", "", "", "88.2", "80.6", "", "58.9", "", "2", "0", "", "101", "1", "1", "175", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.5", "97.6", "", "", "", "", "96.3"]} -{"pcdb_id": 1664, "brand_name": "Keston", "model_name": "K", "model_qualifier": "130", "winter_efficiency_pct": 86.3, "summer_efficiency_pct": 78.7, "comparative_hot_water_efficiency_pct": 57.5, "output_kw_max": 40.5, "final_year_of_manufacture": null, "raw": ["001664", "000022", "0", "2012/Mar/27 10:12", "Keston Boilers", "Keston", "K", "130", "Keston 130", "1998", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "37.7", "40.5", "", "", "86.3", "78.7", "", "57.5", "", "2", "", "", "101", "1", "1", "500", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "89.6", "95.4", "", "", "", "", "94.3"]} -{"pcdb_id": 1665, "brand_name": "Keston", "model_name": "K", "model_qualifier": "130P", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 80.7, "comparative_hot_water_efficiency_pct": 59.0, "output_kw_max": 40.5, "final_year_of_manufacture": null, "raw": ["001665", "000022", "0", "2012/Mar/27 10:12", "Keston Boilers", "Keston", "K", "130P", "Keston 130 LPG", "1998", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "37.7", "40.5", "", "", "88.3", "80.7", "", "59.0", "", "2", "0", "", "101", "1", "1", "500", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.6", "97.5", "", "", "", "", "96.4"]} -{"pcdb_id": 1666, "brand_name": "Keston", "model_name": "K", "model_qualifier": "170", "winter_efficiency_pct": 87.5, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 54.5, "final_year_of_manufacture": null, "raw": ["001666", "000022", "0", "2012/Mar/27 10:12", "Keston Boilers", "Keston", "K", "170", "Keston 170", "1996", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "49.8", "54.5", "", "", "87.5", "79.9", "", "58.4", "", "2", "", "", "101", "1", "1", "500", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.6", "98.0", "", "", "", "", "96.6"]} -{"pcdb_id": 1667, "brand_name": "Keston", "model_name": "K", "model_qualifier": "170P", "winter_efficiency_pct": 89.5, "summer_efficiency_pct": 81.9, "comparative_hot_water_efficiency_pct": 59.8, "output_kw_max": 55.8, "final_year_of_manufacture": null, "raw": ["001667", "000022", "0", "2012/Mar/27 10:12", "Keston Boilers", "Keston", "K", "170P", "Keston 170 LPG", "1996", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "51", "55.8", "", "", "89.5", "81.9", "", "59.8", "", "2", "0", "", "101", "1", "1", "500", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "92.7", "100.2", "", "", "", "", "98.8"]} -{"pcdb_id": 1670, "brand_name": "Yorkpark", "model_name": "Microstar", "model_qualifier": "THR 25", "winter_efficiency_pct": 87.5, "summer_efficiency_pct": 78.5, "comparative_hot_water_efficiency_pct": 57.3, "output_kw_max": 25.0, "final_year_of_manufacture": null, "raw": ["001670", "000036", "0", "2012/Mar/27 10:12", "Yorkpark", "Yorkpark", "Microstar", "THR 25", "THR 5-25", "1997", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "25", "25", "", "", "87.5", "78.5", "", "57.3", "", "2", "", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "85.6", "96.9", "", "", "", "", "94.7"]} -{"pcdb_id": 1677, "brand_name": "Yorkpark", "model_name": "Microstar", "model_qualifier": "THR 50", "winter_efficiency_pct": 86.5, "summer_efficiency_pct": 77.5, "comparative_hot_water_efficiency_pct": 56.6, "output_kw_max": 50.0, "final_year_of_manufacture": null, "raw": ["001677", "000036", "0", "2012/Mar/27 10:12", "Yorkpark", "Yorkpark", "Microstar", "THR 50", "THR 10-50", "1997", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "50", "50", "", "", "86.5", "77.5", "", "56.6", "", "2", "", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "84.7", "95.5", "", "", "", "", "93.5"]} -{"pcdb_id": 1681, "brand_name": "Yorkpark", "model_name": "Microstar", "model_qualifier": "25", "winter_efficiency_pct": 86.8, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 25.0, "final_year_of_manufacture": null, "raw": ["001681", "000036", "0", "2012/Mar/27 10:12", "Yorkpark", "Yorkpark", "Microstar", "25", "MZ 11/18/25", "1993", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "11", "25", "", "", "86.8", "79.2", "", "57.8", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "88.1", "97.1", "", "", "", "", "95.4"]} -{"pcdb_id": 1683, "brand_name": "Yorkpark", "model_name": "Microstar", "model_qualifier": "25 Combi", "winter_efficiency_pct": 86.8, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 55.9, "output_kw_max": 25.0, "final_year_of_manufacture": null, "raw": ["001683", "000036", "0", "1999/Sep/28 17:06", "Yorkpark", "Yorkpark", "Microstar", "25 Combi", "MZ 25 S", "1993", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "25", "25", "", "", "86.8", "79.6", "", "55.9", "", "2", "", "", "103", "1", "1", "", "", "1", "", "", "12.3", "0", "30", "2", "65", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "88.1", "97.1", "", "", "", "", "95.4"]} -{"pcdb_id": 1687, "brand_name": "Yorkpark", "model_name": "Yorkstar", "model_qualifier": "20", "winter_efficiency_pct": 86.1, "summer_efficiency_pct": 78.3, "comparative_hot_water_efficiency_pct": 57.2, "output_kw_max": 24.0, "final_year_of_manufacture": null, "raw": ["001687", "000036", "0", "2012/Mar/27 10:12", "Yorkpark", "Yorkpark", "Yorkstar", "20", "FCX 20", "1990", "current", "4", "1", "1", "1", "0", "", "", "2", "2", "2", "20", "24", "", "", "86.1", "78.3", "", "57.2", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "87.8", "92.6", "", "", "", "", "91.7"]} -{"pcdb_id": 1691, "brand_name": "Yorkpark", "model_name": "Microstar", "model_qualifier": "40", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 40.0, "final_year_of_manufacture": null, "raw": ["001691", "000036", "0", "2012/Mar/27 10:12", "Yorkpark", "Yorkpark", "Microstar", "40", "MZ 20/40", "1992", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "40", "40", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "96.9", "", "", "", "", "95.2"]} -{"pcdb_id": 1692, "brand_name": "Alpha", "model_name": "280E", "model_qualifier": "Alpha Combimax 600", "winter_efficiency_pct": 80.1, "summer_efficiency_pct": 71.0, "comparative_hot_water_efficiency_pct": 36.6, "output_kw_max": 28.0, "final_year_of_manufacture": 2003, "raw": ["001692", "000001", "0", "2024/Jan/31 10:17", "Alpha Therm", "Alpha", "280E", "Alpha Combimax 600", "", "1998", "2003", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "28", "28", "", "", "80.1", "71.0", "", "36.6", "", "2", "", "", "106", "1", "2", "260", "5", "2", "1", "0", "60", "0", "15", "2", "56", "0.8", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.4", "80.5", "", "", "", "", "80.7"]} -{"pcdb_id": 1693, "brand_name": "Alpha", "model_name": "240E", "model_qualifier": "", "winter_efficiency_pct": 79.2, "summer_efficiency_pct": 69.1, "comparative_hot_water_efficiency_pct": 48.6, "output_kw_max": 23.3, "final_year_of_manufacture": 2003, "raw": ["001693", "000001", "0", "2006/Jan/17 12:55", "Alpha Therm", "Alpha", "240E", "", "", "1995", "2003", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "23.3", "23.3", "", "", "79.2", "69.1", "", "48.6", "", "2", "", "", "104", "1", "2", "170", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.7", "79.1", "", "", "", "", "79.6"]} -{"pcdb_id": 1694, "brand_name": "Alpha", "model_name": "240E", "model_qualifier": "Alpha Combimax 350", "winter_efficiency_pct": 79.5, "summer_efficiency_pct": 70.4, "comparative_hot_water_efficiency_pct": 38.4, "output_kw_max": 23.3, "final_year_of_manufacture": 2003, "raw": ["001694", "000001", "0", "2024/Jan/31 10:17", "Alpha Therm", "Alpha", "240E", "Alpha Combimax 350", "", "1998", "2003", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "23.3", "23.3", "", "", "79.5", "70.4", "", "38.4", "", "2", "", "", "106", "1", "2", "260", "5", "2", "1", "0", "35", "0", "15", "2", "56", "0.97", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.7", "79.1", "", "", "", "", "79.6"]} -{"pcdb_id": 1695, "brand_name": "Alpha", "model_name": "280E", "model_qualifier": "", "winter_efficiency_pct": 79.8, "summer_efficiency_pct": 69.7, "comparative_hot_water_efficiency_pct": 49.0, "output_kw_max": 28.0, "final_year_of_manufacture": 2003, "raw": ["001695", "000001", "0", "2006/Jan/17 12:55", "Alpha Therm", "Alpha", "280E", "", "", "1996", "2003", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "28", "28", "", "", "79.8", "69.7", "", "49.0", "", "2", "", "", "104", "1", "2", "170", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.4", "80.5", "", "", "", "", "80.7"]} -{"pcdb_id": 1707, "brand_name": "Worcester", "model_name": "24 Sbi", "model_qualifier": "RSF", "winter_efficiency_pct": 79.2, "summer_efficiency_pct": 69.1, "comparative_hot_water_efficiency_pct": 50.5, "output_kw_max": 24.0, "final_year_of_manufacture": 2005, "raw": ["001707", "000035", "0", "2020/Sep/02 14:03", "Worcester Heat Systems", "Worcester", "24 Sbi", "RSF", "41 311 44", "1999", "2005", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "15", "24", "", "", "79.2", "69.1", "", "50.5", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.5", "79.0", "", "", "", "", "79.7"]} -{"pcdb_id": 1709, "brand_name": "Worcester", "model_name": "High Flow 400", "model_qualifier": "BF", "winter_efficiency_pct": 79.7, "summer_efficiency_pct": 71.8, "comparative_hot_water_efficiency_pct": 37.0, "output_kw_max": 24.0, "final_year_of_manufacture": 2002, "raw": ["001709", "000035", "0", "2024/Jan/31 10:17", "Worcester Heat Systems", "Worcester", "High Flow 400", "BF", "47 311 19", "1997", "2002", "1", "1", "1", "2", "0", "", "", "1", "2", "1", "8.8", "24", "", "", "79.7", "71.8", "", "37.0", "", "2", "", "", "105", "2", "1", "", "", "1", "2", "0", "65", "0", "25", "3", "70", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.8", "88.7", "", "", "", "", "88.5"]} -{"pcdb_id": 1711, "brand_name": "British Gas/Scottish Gas", "model_name": "C1", "model_qualifier": "RSF", "winter_efficiency_pct": 79.1, "summer_efficiency_pct": 69.0, "comparative_hot_water_efficiency_pct": 48.5, "output_kw_max": 28.0, "final_year_of_manufacture": null, "raw": ["001711", "000035", "0", "2002/Aug/14 10:22", "Worcester Heat Systems", "British Gas/Scottish Gas", "C1", "RSF", "47 311 51", "1999", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "28", "28", "", "", "79.1", "69.0", "", "48.5", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "84.0", "77.7", "", "", "", "", "78.9"]} -{"pcdb_id": 1712, "brand_name": "Worcester", "model_name": "Highflow 400", "model_qualifier": "OF", "winter_efficiency_pct": 79.2, "summer_efficiency_pct": 69.9, "comparative_hot_water_efficiency_pct": 49.1, "output_kw_max": 24.0, "final_year_of_manufacture": 2002, "raw": ["001712", "000035", "0", "2002/Jan/09 12:33", "Worcester Heat Systems", "Worcester", "Highflow 400", "OF", "47 311 20", "1997", "2002", "1", "1", "1", "2", "0", "", "", "1", "1", "1", "8.8", "24", "", "", "79.2", "69.9", "", "49.1", "", "2", "", "", "103", "2", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.0", "88.7", "", "", "", "", "87.4"]} -{"pcdb_id": 1713, "brand_name": "Worcester", "model_name": "Highflow 400", "model_qualifier": "RSF", "winter_efficiency_pct": 79.9, "summer_efficiency_pct": 72.0, "comparative_hot_water_efficiency_pct": 37.1, "output_kw_max": 24.0, "final_year_of_manufacture": 2002, "raw": ["001713", "000035", "0", "2024/Jan/31 10:17", "Worcester Heat Systems", "Worcester", "Highflow 400", "RSF", "47 311 18", "1997", "2002", "1", "1", "1", "2", "0", "", "", "1", "2", "2", "8.8", "24", "", "", "79.9", "72.0", "", "37.1", "", "2", "", "", "105", "1", "1", "", "", "1", "2", "0", "65", "0", "25", "3", "70", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.1", "81.5", "", "", "", "", "81.6"]} -{"pcdb_id": 1716, "brand_name": "Worcester", "model_name": "15 Sbi", "model_qualifier": "RSF", "winter_efficiency_pct": 80.8, "summer_efficiency_pct": 70.7, "comparative_hot_water_efficiency_pct": 51.6, "output_kw_max": 15.0, "final_year_of_manufacture": 2005, "raw": ["001716", "000035", "0", "2020/Sep/02 14:04", "Worcester Heat Systems", "Worcester", "15 Sbi", "RSF", "41 311 43", "1999", "2005", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "6", "15", "", "", "80.8", "70.7", "", "51.6", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.2", "83.5", "", "", "", "", "83.1"]} -{"pcdb_id": 1717, "brand_name": "Servowarm", "model_name": "Elite HE 30", "model_qualifier": "", "winter_efficiency_pct": 82.2, "summer_efficiency_pct": 74.6, "comparative_hot_water_efficiency_pct": 54.5, "output_kw_max": 8.8, "final_year_of_manufacture": 2000, "raw": ["001717", "000091", "0", "2012/Mar/27 10:12", "Malvern Boilers", "Servowarm", "Elite HE 30", "", "GC No 47.555.07", "1993", "2000", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "8.8", "8.8", "", "", "82.2", "74.6", "", "54.5", "", "2", "", "", "101", "1", "1", "40", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "84.2", "88.7", "", "", "", "", "87.9"]} -{"pcdb_id": 1718, "brand_name": "Servowarm", "model_name": "Elite HE 70/80", "model_qualifier": "", "winter_efficiency_pct": 82.9, "summer_efficiency_pct": 75.3, "comparative_hot_water_efficiency_pct": 55.0, "output_kw_max": 23.5, "final_year_of_manufacture": 2000, "raw": ["001718", "000091", "0", "2012/Mar/27 10:12", "Malvern Boilers", "Servowarm", "Elite HE 70/80", "", "GC No 47.555.12", "1995", "2000", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "20.6", "23.5", "", "", "82.9", "75.3", "", "55.0", "", "2", "", "", "101", "1", "1", "40", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "85.7", "88.7", "", "", "", "", "88.2"]} -{"pcdb_id": 1719, "brand_name": "Servowarm", "model_name": "Elite HE Combi", "model_qualifier": "", "winter_efficiency_pct": 84.6, "summer_efficiency_pct": 76.0, "comparative_hot_water_efficiency_pct": 53.5, "output_kw_max": 23.5, "final_year_of_manufacture": null, "raw": ["001719", "000091", "0", "2006/Jan/17 12:31", "Malvern Boilers", "Servowarm", "Elite HE Combi", "", "GC No 47.555.04", "1995", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "23.5", "23.5", "", "", "84.6", "76.0", "", "53.5", "", "2", "", "", "104", "1", "2", "120", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "86.1", "89.0", "", "", "", "", "88.5"]} -{"pcdb_id": 1720, "brand_name": "Servowarm", "model_name": "Elite HE 50", "model_qualifier": "", "winter_efficiency_pct": 83.2, "summer_efficiency_pct": 75.6, "comparative_hot_water_efficiency_pct": 55.2, "output_kw_max": 14.7, "final_year_of_manufacture": 2000, "raw": ["001720", "000091", "0", "2012/Mar/27 10:12", "Malvern Boilers", "Servowarm", "Elite HE 50", "", "GC No 47.555.09", "1993", "2000", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "14.7", "14.7", "", "", "83.2", "75.6", "", "55.2", "", "2", "", "", "101", "1", "1", "40", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "85.7", "89.5", "", "", "", "", "88.8"]} -{"pcdb_id": 1721, "brand_name": "Servowarm", "model_name": "Elite HE 40", "model_qualifier": "", "winter_efficiency_pct": 82.6, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 11.7, "final_year_of_manufacture": 2000, "raw": ["001721", "000091", "0", "2012/Mar/27 10:12", "Malvern Boilers", "Servowarm", "Elite HE 40", "", "GC No 47.555.08", "1993", "2000", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "11.7", "11.7", "", "", "82.6", "75.0", "", "54.8", "", "2", "", "", "101", "1", "1", "40", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "85.0", "88.7", "", "", "", "", "88.0"]} -{"pcdb_id": 1722, "brand_name": "Warmworld", "model_name": "Warmworld HE 30", "model_qualifier": "", "winter_efficiency_pct": 82.2, "summer_efficiency_pct": 74.6, "comparative_hot_water_efficiency_pct": 54.5, "output_kw_max": 8.8, "final_year_of_manufacture": null, "raw": ["001722", "000034", "0", "2012/Mar/27 10:12", "Warmworld", "Warmworld", "Warmworld HE 30", "", "GC No 41.555.04", "1993", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "8.8", "8.8", "", "", "82.2", "74.6", "", "54.5", "", "2", "", "", "101", "1", "1", "40", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "84.2", "88.7", "", "", "", "", "87.9"]} -{"pcdb_id": 1723, "brand_name": "Warmworld", "model_name": "Warmworld HE 40", "model_qualifier": "", "winter_efficiency_pct": 82.6, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 11.7, "final_year_of_manufacture": null, "raw": ["001723", "000034", "0", "2012/Mar/27 10:12", "Warmworld", "Warmworld", "Warmworld HE 40", "", "GC No 41.555.05", "1993", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "11.7", "11.7", "", "", "82.6", "75.0", "", "54.8", "", "2", "", "", "101", "1", "1", "40", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "85.0", "88.7", "", "", "", "", "88.0"]} -{"pcdb_id": 1724, "brand_name": "Warmworld", "model_name": "Warmworld HE 50", "model_qualifier": "", "winter_efficiency_pct": 83.2, "summer_efficiency_pct": 75.6, "comparative_hot_water_efficiency_pct": 55.2, "output_kw_max": 14.7, "final_year_of_manufacture": null, "raw": ["001724", "000034", "0", "2012/Mar/27 10:12", "Warmworld", "Warmworld", "Warmworld HE 50", "", "GC No 41.555.06", "1993", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "14.7", "14.7", "", "", "83.2", "75.6", "", "55.2", "", "2", "", "", "101", "1", "1", "40", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "85.7", "89.5", "", "", "", "", "88.8"]} -{"pcdb_id": 1725, "brand_name": "Warmworld", "model_name": "Warmworld HE 70/80", "model_qualifier": "", "winter_efficiency_pct": 82.9, "summer_efficiency_pct": 75.3, "comparative_hot_water_efficiency_pct": 55.0, "output_kw_max": 23.5, "final_year_of_manufacture": null, "raw": ["001725", "000034", "0", "2012/Mar/27 10:12", "Warmworld", "Warmworld", "Warmworld HE 70/80", "", "GC No 41.555.11", "1995", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "20.6", "23.5", "", "", "82.9", "75.3", "", "55.0", "", "2", "", "", "101", "1", "1", "40", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "85.7", "88.7", "", "", "", "", "88.2"]} -{"pcdb_id": 1726, "brand_name": "Warmworld", "model_name": "Warmworld Combi", "model_qualifier": "", "winter_efficiency_pct": 84.6, "summer_efficiency_pct": 76.0, "comparative_hot_water_efficiency_pct": 53.5, "output_kw_max": 23.5, "final_year_of_manufacture": null, "raw": ["001726", "000034", "0", "2006/Jan/31 12:06", "Warmworld", "Warmworld", "Warmworld Combi", "", "GC No 47.555.03", "1995", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "23.5", "23.5", "", "", "84.6", "76.0", "", "53.5", "", "2", "", "", "104", "1", "2", "120", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "86.1", "89.0", "", "", "", "", "88.5"]} -{"pcdb_id": 1727, "brand_name": "Worcester", "model_name": "35 Cdi", "model_qualifier": "RSF", "winter_efficiency_pct": 79.8, "summer_efficiency_pct": 69.7, "comparative_hot_water_efficiency_pct": 49.0, "output_kw_max": 25.0, "final_year_of_manufacture": 2002, "raw": ["001727", "000035", "0", "2002/Sep/27 13:16", "Worcester Heat Systems", "Worcester", "35 Cdi", "RSF", "47 311 39", "1998", "2002", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "25", "25", "", "", "79.8", "69.7", "", "49.0", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.7", "79.4", "", "", "", "", "80.0"]} -{"pcdb_id": 1730, "brand_name": "Worcester", "model_name": "24 I", "model_qualifier": "RSF", "winter_efficiency_pct": 77.0, "summer_efficiency_pct": 66.9, "comparative_hot_water_efficiency_pct": 47.1, "output_kw_max": 23.4, "final_year_of_manufacture": 2001, "raw": ["001730", "000035", "0", "2001/Nov/22 08:42", "Worcester Heat Systems", "Worcester", "24 I", "RSF", "47 311 37", "1998", "2001", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "23.4", "23.4", "", "", "77.0", "66.9", "", "47.1", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "79.7", "76.7", "", "", "", "", "77.3"]} -{"pcdb_id": 1731, "brand_name": "Worcester", "model_name": "Bosch Greenstar ZWBR", "model_qualifier": "7-25A", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 56.4, "output_kw_max": 25.3, "final_year_of_manufacture": 2001, "raw": ["001731", "000035", "0", "2003/May/29 14:12", "Worcester Heat Systems", "Worcester", "Bosch Greenstar ZWBR", "7-25A", "47 311 44", "1999", "2001", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "25.3", "25.3", "", "", "88.8", "80.2", "", "56.4", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.2", "98.2", "", "", "", "", "96.5"]} -{"pcdb_id": 1733, "brand_name": "Worcester", "model_name": "80 ic", "model_qualifier": "RSF", "winter_efficiency_pct": 76.1, "summer_efficiency_pct": 66.0, "comparative_hot_water_efficiency_pct": 46.4, "output_kw_max": 20.0, "final_year_of_manufacture": 2001, "raw": ["001733", "000035", "0", "2006/Jan/17 12:55", "Worcester Heat Systems", "Worcester", "80 ic", "RSF", "", "1999", "2001", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "20", "20", "", "", "76.1", "66.0", "", "46.4", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.0", "73.5", "", "", "", "", "74.9"]} -{"pcdb_id": 1736, "brand_name": "Worcester", "model_name": "Heat Slave", "model_qualifier": "15/19.OSO", "winter_efficiency_pct": 84.6, "summer_efficiency_pct": 76.5, "comparative_hot_water_efficiency_pct": 41.5, "output_kw_max": 19.0, "final_year_of_manufacture": 2008, "raw": ["001736", "000035", "0", "2024/Jan/31 10:17", "Worcester Heat Systems", "Worcester", "Heat Slave", "15/19.OSO", "C14769/3-1", "1997", "2008", "4", "1", "1", "2", "0", "", "", "1", "1", "2", "19", "19", "", "", "84.6", "76.5", "", "41.5", "", "2", "", "", "203", "1", "2", "", "", "1", "2", "0", "46", "0", "25", "3", "70", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "85.6", "87.9", "", "", "", "", "87.5"]} -{"pcdb_id": 1737, "brand_name": "Worcester", "model_name": "Heat Slave", "model_qualifier": "12/14.OSO", "winter_efficiency_pct": 83.7, "summer_efficiency_pct": 75.6, "comparative_hot_water_efficiency_pct": 41.0, "output_kw_max": 14.0, "final_year_of_manufacture": 2002, "raw": ["001737", "000035", "0", "2024/Jan/31 10:17", "Worcester Heat Systems", "Worcester", "Heat Slave", "12/14.OSO", "C14769/2-1", "1997", "2002", "4", "1", "1", "2", "0", "", "", "1", "1", "2", "12", "14", "", "", "83.7", "75.6", "", "41.0", "", "2", "", "", "203", "1", "1", "", "", "1", "2", "0", "46", "0", "25", "3", "70", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "83.7", "88.9", "", "", "", "", "87.9"]} -{"pcdb_id": 1738, "brand_name": "Worcester", "model_name": "Heat Slave", "model_qualifier": "12/14.RSO", "winter_efficiency_pct": 83.7, "summer_efficiency_pct": 75.6, "comparative_hot_water_efficiency_pct": 41.0, "output_kw_max": 14.0, "final_year_of_manufacture": 2002, "raw": ["001738", "000035", "0", "2024/Jan/31 10:17", "Worcester Heat Systems", "Worcester", "Heat Slave", "12/14.RSO", "C14769/2-1", "1997", "2002", "4", "1", "1", "2", "0", "", "", "1", "1", "2", "12", "14", "", "", "83.7", "75.6", "", "41.0", "", "2", "", "", "203", "1", "1", "", "", "1", "2", "0", "46", "0", "25", "3", "70", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "83.7", "88.9", "", "", "", "", "87.9"]} -{"pcdb_id": 1739, "brand_name": "Worcester", "model_name": "Heat Slave", "model_qualifier": "15/19.RSO", "winter_efficiency_pct": 84.6, "summer_efficiency_pct": 76.5, "comparative_hot_water_efficiency_pct": 41.5, "output_kw_max": 19.0, "final_year_of_manufacture": 2008, "raw": ["001739", "000035", "0", "2024/Jan/31 10:17", "Worcester Heat Systems", "Worcester", "Heat Slave", "15/19.RSO", "C14769/4-1", "1997", "2008", "4", "1", "1", "2", "0", "", "", "1", "1", "2", "19", "19", "", "", "84.6", "76.5", "", "41.5", "", "2", "", "", "203", "1", "2", "", "", "1", "2", "0", "46", "0", "25", "3", "70", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "85.6", "87.9", "", "", "", "", "87.5"]} -{"pcdb_id": 1740, "brand_name": "Worcester", "model_name": "Heat Slave", "model_qualifier": "20/25.RSO", "winter_efficiency_pct": 84.6, "summer_efficiency_pct": 76.5, "comparative_hot_water_efficiency_pct": 41.5, "output_kw_max": 20.0, "final_year_of_manufacture": 2002, "raw": ["001740", "000035", "0", "2024/Jan/31 10:17", "Worcester Heat Systems", "Worcester", "Heat Slave", "20/25.RSO", "C14769/3-1", "1997", "2002", "4", "1", "1", "2", "0", "", "", "1", "1", "2", "20", "20", "", "", "84.6", "76.5", "", "41.5", "", "2", "", "", "203", "1", "2", "", "", "1", "2", "0", "46", "0", "25", "3", "70", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "85.6", "87.9", "", "", "", "", "87.5"]} -{"pcdb_id": 1741, "brand_name": "Worcester", "model_name": "Heat Slave", "model_qualifier": "20/25.OSO", "winter_efficiency_pct": 83.3, "summer_efficiency_pct": 75.2, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 25.0, "final_year_of_manufacture": 2002, "raw": ["001741", "000035", "0", "2024/Jan/31 10:17", "Worcester Heat Systems", "Worcester", "Heat Slave", "20/25.OSO", "C14769/4-1", "1997", "2002", "4", "1", "1", "2", "0", "", "", "1", "1", "2", "20", "25", "", "", "83.3", "75.2", "", "40.8", "", "2", "", "", "203", "1", "1", "", "", "1", "2", "0", "46", "0", "25", "3", "70", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "83.3", "86.8", "", "", "", "", "86.1"]} -{"pcdb_id": 1742, "brand_name": "Worcester", "model_name": "Danesmoor", "model_qualifier": "32/50.000", "winter_efficiency_pct": 84.2, "summer_efficiency_pct": 72.5, "comparative_hot_water_efficiency_pct": 53.0, "output_kw_max": 50.0, "final_year_of_manufacture": 2002, "raw": ["001742", "000035", "0", "2012/Mar/27 10:12", "Worcester Heat Systems", "Worcester", "Danesmoor", "32/50.000", "C14769/6-1", "1995", "2002", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "32", "50", "", "", "84.2", "72.5", "", "53.0", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "84.0", "84.4", "", "", "", "", "84.3"]} -{"pcdb_id": 1743, "brand_name": "Worcester", "model_name": "Danesmoor", "model_qualifier": "50/70.000", "winter_efficiency_pct": 85.7, "summer_efficiency_pct": 74.0, "comparative_hot_water_efficiency_pct": 54.0, "output_kw_max": 70.0, "final_year_of_manufacture": 2002, "raw": ["001743", "000035", "0", "2020/Sep/02 14:06", "Worcester Heat Systems", "Worcester", "Danesmoor", "50/70.000", "C14769/7-1", "1995", "2002", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "50", "70", "", "", "85.7", "74.0", "", "54.0", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "84.2", "87.8", "", "", "", "", "87.1"]} -{"pcdb_id": 1744, "brand_name": "Worcester", "model_name": "Danesmoor System", "model_qualifier": "15.19.OSO", "winter_efficiency_pct": 86.4, "summer_efficiency_pct": 74.7, "comparative_hot_water_efficiency_pct": 54.6, "output_kw_max": 19.0, "final_year_of_manufacture": 2008, "raw": ["001744", "000035", "0", "2020/Sep/02 14:10", "Worcester Heat Systems", "Worcester", "Danesmoor System", "15.19.OSO", "C14769/3-1", "1995", "2008", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "15", "19", "", "", "86.4", "74.7", "", "54.6", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.6", "87.9", "", "", "", "", "87.5"]} -{"pcdb_id": 1746, "brand_name": "Worcester", "model_name": "24 Cdi", "model_qualifier": "OF", "winter_efficiency_pct": 77.1, "summer_efficiency_pct": 67.0, "comparative_hot_water_efficiency_pct": 47.1, "output_kw_max": 24.0, "final_year_of_manufacture": 2002, "raw": ["001746", "000035", "0", "2002/Feb/21 14:21", "Worcester Heat Systems", "Worcester", "24 Cdi", "OF", "47 311 32", "1997", "2002", "1", "2", "1", "2", "0", "", "", "1", "1", "1", "24.0", "24.0", "", "", "77.1", "67.0", "", "47.1", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "80.1", "76.4", "", "", "", "", "77.1"]} -{"pcdb_id": 1747, "brand_name": "Worcester", "model_name": "24 Cdi", "model_qualifier": "BF", "winter_efficiency_pct": 80.3, "summer_efficiency_pct": 70.2, "comparative_hot_water_efficiency_pct": 49.4, "output_kw_max": 24.0, "final_year_of_manufacture": 2005, "raw": ["001747", "000035", "0", "2020/Sep/02 14:10", "Worcester Heat Systems", "Worcester", "24 Cdi", "BF", "47 311 29", "1997", "2005", "1", "2", "1", "2", "0", "", "", "1", "2", "1", "24", "24", "", "", "80.3", "70.2", "", "49.4", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.2", "80.8", "", "", "", "", "81.1"]} -{"pcdb_id": 1749, "brand_name": "Worcester", "model_name": "24 Cdi", "model_qualifier": "RSF", "winter_efficiency_pct": 76.9, "summer_efficiency_pct": 66.8, "comparative_hot_water_efficiency_pct": 47.0, "output_kw_max": 24.0, "final_year_of_manufacture": 2001, "raw": ["001749", "000035", "0", "2006/Jan/17 12:55", "Worcester Heat Systems", "Worcester", "24 Cdi", "RSF", "47 311 30", "1997", "2001", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "24.0", "24.0", "", "", "76.9", "66.8", "", "47.0", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "79.8", "76.3", "", "", "", "", "77.0"]} -{"pcdb_id": 1750, "brand_name": "Worcester", "model_name": "24 LE", "model_qualifier": "RSF", "winter_efficiency_pct": 76.9, "summer_efficiency_pct": 66.8, "comparative_hot_water_efficiency_pct": 47.0, "output_kw_max": 24.0, "final_year_of_manufacture": 2001, "raw": ["001750", "000035", "0", "2001/Nov/22 08:43", "Worcester Heat Systems", "Worcester", "24 LE", "RSF", "47 311 30", "1998", "2001", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "24", "24", "", "", "76.9", "66.8", "", "47.0", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "79.8", "76.3", "", "", "", "", "77.0"]} -{"pcdb_id": 1752, "brand_name": "Worcester", "model_name": "Bosch", "model_qualifier": "90/110.000", "winter_efficiency_pct": 86.2, "summer_efficiency_pct": 74.5, "comparative_hot_water_efficiency_pct": 54.4, "output_kw_max": 32.0, "final_year_of_manufacture": 2008, "raw": ["001752", "000035", "0", "2020/Sep/02 14:10", "Worcester Heat Systems", "Worcester", "Bosch", "90/110.000", "C14769/5-1", "1997", "2008", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "26", "32", "", "", "86.2", "74.5", "", "54.4", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.3", "88.1", "", "", "", "", "87.5"]} -{"pcdb_id": 1753, "brand_name": "Worcester", "model_name": "Bosch", "model_qualifier": "70/90.000", "winter_efficiency_pct": 85.0, "summer_efficiency_pct": 73.3, "comparative_hot_water_efficiency_pct": 53.6, "output_kw_max": 25.0, "final_year_of_manufacture": 2002, "raw": ["001753", "000035", "0", "2020/Sep/02 14:10", "Worcester Heat Systems", "Worcester", "Bosch", "70/90.000", "C14769/4-1", "1997", "2002", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "20", "25", "", "", "85.0", "73.3", "", "53.6", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "83.3", "86.8", "", "", "", "", "86.1"]} -{"pcdb_id": 1754, "brand_name": "Worcester", "model_name": "Bosch", "model_qualifier": "50/70.000", "winter_efficiency_pct": 86.4, "summer_efficiency_pct": 74.7, "comparative_hot_water_efficiency_pct": 54.6, "output_kw_max": 19.0, "final_year_of_manufacture": 2008, "raw": ["001754", "000035", "0", "2020/Sep/02 14:11", "Worcester Heat Systems", "Worcester", "Bosch", "50/70.000", "C14769/3-1", "1997", "2008", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "15", "19", "", "", "86.4", "74.7", "", "54.6", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.6", "87.9", "", "", "", "", "87.5"]} -{"pcdb_id": 1756, "brand_name": "Worcester", "model_name": "28 LE", "model_qualifier": "RSF", "winter_efficiency_pct": 79.8, "summer_efficiency_pct": 69.7, "comparative_hot_water_efficiency_pct": 49.0, "output_kw_max": 24.0, "final_year_of_manufacture": 2005, "raw": ["001756", "000035", "0", "2020/Sep/02 14:11", "Worcester Heat Systems", "Worcester", "28 LE", "RSF", "47 311 34", "1998", "2005", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "24", "24", "", "", "79.8", "69.7", "", "49.0", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.2", "79.7", "", "", "", "", "80.2"]} -{"pcdb_id": 1758, "brand_name": "Worcester", "model_name": "28 Cdi", "model_qualifier": "RSF", "winter_efficiency_pct": 79.8, "summer_efficiency_pct": 69.7, "comparative_hot_water_efficiency_pct": 49.0, "output_kw_max": 24.0, "final_year_of_manufacture": 2005, "raw": ["001758", "000035", "0", "2020/Sep/02 14:11", "Worcester Heat Systems", "Worcester", "28 Cdi", "RSF", "47 311 34", "1997", "2005", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "24", "24", "", "", "79.8", "69.7", "", "49.0", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.2", "79.7", "", "", "", "", "80.2"]} -{"pcdb_id": 1760, "brand_name": "Worcester", "model_name": "26 Cdi", "model_qualifier": "Xtra", "winter_efficiency_pct": 84.8, "summer_efficiency_pct": 76.2, "comparative_hot_water_efficiency_pct": 53.6, "output_kw_max": 26.0, "final_year_of_manufacture": 2002, "raw": ["001760", "000035", "0", "2002/Aug/14 10:24", "Worcester Heat Systems", "Worcester", "26 Cdi", "Xtra", "47 311 41", "1998", "2002", "1", "2", "2", "2", "0", "", "", "2", "2", "2", "26", "26", "", "", "84.8", "76.2", "", "53.6", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "85.6", "90.1", "", "", "", "", "89.2"]} -{"pcdb_id": 1761, "brand_name": "Worcester", "model_name": "Danesmoor System", "model_qualifier": "12/14.RSO", "winter_efficiency_pct": 85.4, "summer_efficiency_pct": 73.7, "comparative_hot_water_efficiency_pct": 53.8, "output_kw_max": 14.0, "final_year_of_manufacture": 2002, "raw": ["001761", "000035", "0", "2020/Sep/02 14:11", "Worcester Heat Systems", "Worcester", "Danesmoor System", "12/14.RSO", "C14769/2-1", "1995", "2002", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "12", "14", "", "", "85.4", "73.7", "", "53.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "83.7", "88.9", "", "", "", "", "87.9"]} -{"pcdb_id": 1762, "brand_name": "Worcester", "model_name": "Danesmoor System", "model_qualifier": "12/14.OSO", "winter_efficiency_pct": 85.4, "summer_efficiency_pct": 73.7, "comparative_hot_water_efficiency_pct": 53.8, "output_kw_max": 14.0, "final_year_of_manufacture": 2002, "raw": ["001762", "000035", "0", "2020/Sep/02 14:11", "Worcester Heat Systems", "Worcester", "Danesmoor System", "12/14.OSO", "C14769/2-1", "1995", "2002", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "12", "14", "", "", "85.4", "73.7", "", "53.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "83.7", "88.9", "", "", "", "", "87.9"]} -{"pcdb_id": 1763, "brand_name": "Worcester", "model_name": "Danesmoor System", "model_qualifier": "15/19.RSO", "winter_efficiency_pct": 86.4, "summer_efficiency_pct": 74.7, "comparative_hot_water_efficiency_pct": 54.6, "output_kw_max": 19.0, "final_year_of_manufacture": 2008, "raw": ["001763", "000035", "0", "2020/Sep/02 14:11", "Worcester Heat Systems", "Worcester", "Danesmoor System", "15/19.RSO", "C14769/3-1", "1995", "2008", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "15", "19", "", "", "86.4", "74.7", "", "54.6", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.6", "87.9", "", "", "", "", "87.5"]} -{"pcdb_id": 1764, "brand_name": "Worcester", "model_name": "Danesmoor System", "model_qualifier": "20/25.RSO", "winter_efficiency_pct": 85.0, "summer_efficiency_pct": 73.3, "comparative_hot_water_efficiency_pct": 53.6, "output_kw_max": 25.0, "final_year_of_manufacture": 2002, "raw": ["001764", "000035", "0", "2020/Sep/02 14:11", "Worcester Heat Systems", "Worcester", "Danesmoor System", "20/25.RSO", "C14769/4-1", "1995", "2002", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "20", "25", "", "", "85.0", "73.3", "", "53.6", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "83.3", "86.8", "", "", "", "", "86.1"]} -{"pcdb_id": 1765, "brand_name": "Worcester", "model_name": "Danesmoor System", "model_qualifier": "20/25.OSO", "winter_efficiency_pct": 85.0, "summer_efficiency_pct": 73.3, "comparative_hot_water_efficiency_pct": 53.6, "output_kw_max": 25.0, "final_year_of_manufacture": 2002, "raw": ["001765", "000035", "0", "2020/Sep/02 14:12", "Worcester Heat Systems", "Worcester", "Danesmoor System", "20/25.OSO", "C14769/4-1", "1995", "2002", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "20", "25", "", "", "85.0", "73.3", "", "53.6", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "83.3", "86.8", "", "", "", "", "86.1"]} -{"pcdb_id": 1766, "brand_name": "Worcester", "model_name": "Danesmoor", "model_qualifier": "12/14.ROO", "winter_efficiency_pct": 85.4, "summer_efficiency_pct": 73.7, "comparative_hot_water_efficiency_pct": 53.8, "output_kw_max": 14.0, "final_year_of_manufacture": 2002, "raw": ["001766", "000035", "0", "2020/Sep/02 14:12", "Worcester Heat Systems", "Worcester", "Danesmoor", "12/14.ROO", "C14769/2-1", "1995", "2002", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "12", "14", "", "", "85.4", "73.7", "", "53.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "83.7", "88.9", "", "", "", "", "87.9"]} -{"pcdb_id": 1767, "brand_name": "Worcester", "model_name": "Danesmoor", "model_qualifier": "12/14.OOO", "winter_efficiency_pct": 85.4, "summer_efficiency_pct": 73.7, "comparative_hot_water_efficiency_pct": 53.8, "output_kw_max": 14.0, "final_year_of_manufacture": 2002, "raw": ["001767", "000035", "0", "2020/Sep/02 14:12", "Worcester Heat Systems", "Worcester", "Danesmoor", "12/14.OOO", "C14769/2-1", "1995", "2002", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "12", "14", "", "", "85.4", "73.7", "", "53.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "83.7", "88.9", "", "", "", "", "87.9"]} -{"pcdb_id": 1768, "brand_name": "Worcester", "model_name": "Danesmoor", "model_qualifier": "15/19.ROO", "winter_efficiency_pct": 86.4, "summer_efficiency_pct": 74.7, "comparative_hot_water_efficiency_pct": 54.6, "output_kw_max": 19.0, "final_year_of_manufacture": 2008, "raw": ["001768", "000035", "0", "2020/Sep/02 14:12", "Worcester Heat Systems", "Worcester", "Danesmoor", "15/19.ROO", "C14769/3-1", "1995", "2008", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "15", "19", "", "", "86.4", "74.7", "", "54.6", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.6", "87.9", "", "", "", "", "87.5"]} -{"pcdb_id": 1770, "brand_name": "Worcester", "model_name": "Danesmoor", "model_qualifier": "15/19.OOO", "winter_efficiency_pct": 86.4, "summer_efficiency_pct": 74.7, "comparative_hot_water_efficiency_pct": 54.6, "output_kw_max": 19.0, "final_year_of_manufacture": 2008, "raw": ["001770", "000035", "0", "2020/Sep/02 14:12", "Worcester Heat Systems", "Worcester", "Danesmoor", "15/19.OOO", "C14769/3-1", "1995", "2008", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "15", "19", "", "", "86.4", "74.7", "", "54.6", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.6", "87.9", "", "", "", "", "87.5"]} -{"pcdb_id": 1774, "brand_name": "Worcester", "model_name": "Danesmoor", "model_qualifier": "20/25.ROO", "winter_efficiency_pct": 85.0, "summer_efficiency_pct": 73.3, "comparative_hot_water_efficiency_pct": 53.6, "output_kw_max": 25.0, "final_year_of_manufacture": 2002, "raw": ["001774", "000035", "0", "2020/Sep/02 14:12", "Worcester Heat Systems", "Worcester", "Danesmoor", "20/25.ROO", "C14769/4-1", "1995", "2002", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "20", "25", "", "", "85.0", "73.3", "", "53.6", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "83.3", "86.8", "", "", "", "", "86.1"]} -{"pcdb_id": 1776, "brand_name": "Worcester", "model_name": "Danesmoor", "model_qualifier": "20/25.OOO", "winter_efficiency_pct": 85.0, "summer_efficiency_pct": 73.3, "comparative_hot_water_efficiency_pct": 53.6, "output_kw_max": 25.0, "final_year_of_manufacture": 2002, "raw": ["001776", "000035", "0", "2020/Sep/02 14:12", "Worcester Heat Systems", "Worcester", "Danesmoor", "20/25.OOO", "C14769/4-1", "1995", "2002", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "20", "25", "", "", "85.0", "73.3", "", "53.6", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "83.3", "86.8", "", "", "", "", "86.1"]} -{"pcdb_id": 1778, "brand_name": "Worcester", "model_name": "Danesmoor", "model_qualifier": "26/32.ROO", "winter_efficiency_pct": 86.2, "summer_efficiency_pct": 74.5, "comparative_hot_water_efficiency_pct": 54.4, "output_kw_max": 32.0, "final_year_of_manufacture": 2008, "raw": ["001778", "000035", "0", "2020/Sep/02 14:12", "Worcester Heat Systems", "Worcester", "Danesmoor", "26/32.ROO", "C14769/5-1", "1995", "2008", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "26", "32", "", "", "86.2", "74.5", "", "54.4", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.3", "88.1", "", "", "", "", "87.5"]} -{"pcdb_id": 1779, "brand_name": "Worcester", "model_name": "Danesmoor", "model_qualifier": "26/32.OOO", "winter_efficiency_pct": 86.2, "summer_efficiency_pct": 74.5, "comparative_hot_water_efficiency_pct": 54.4, "output_kw_max": 32.0, "final_year_of_manufacture": 2008, "raw": ["001779", "000035", "0", "2020/Sep/02 14:13", "Worcester Heat Systems", "Worcester", "Danesmoor", "26/32.OOO", "C14769/5-1", "1995", "2008", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "26", "32", "", "", "86.2", "74.5", "", "54.4", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.3", "88.1", "", "", "", "", "87.5"]} -{"pcdb_id": 1781, "brand_name": "Worcester", "model_name": "Danesmoor Utility", "model_qualifier": "12/14.ROO", "winter_efficiency_pct": 85.4, "summer_efficiency_pct": 73.7, "comparative_hot_water_efficiency_pct": 53.8, "output_kw_max": 14.0, "final_year_of_manufacture": 2002, "raw": ["001781", "000035", "0", "2020/Sep/02 14:13", "Worcester Heat Systems", "Worcester", "Danesmoor Utility", "12/14.ROO", "C14769/2-1", "1995", "2002", "4", "1", "0", "1", "0", "", "", "1", "1", "2", "12", "14", "", "", "85.4", "73.7", "", "53.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "83.7", "88.9", "", "", "", "", "87.9"]} -{"pcdb_id": 1784, "brand_name": "Worcester", "model_name": "Danesmoor Utility", "model_qualifier": "12/14.OOO", "winter_efficiency_pct": 85.4, "summer_efficiency_pct": 73.7, "comparative_hot_water_efficiency_pct": 53.8, "output_kw_max": 14.0, "final_year_of_manufacture": 2002, "raw": ["001784", "000035", "0", "2020/Sep/02 14:13", "Worcester Heat Systems", "Worcester", "Danesmoor Utility", "12/14.OOO", "C14769/2-1", "1995", "2002", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "12", "14", "", "", "85.4", "73.7", "", "53.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "83.7", "88.9", "", "", "", "", "87.9"]} -{"pcdb_id": 1785, "brand_name": "Worcester", "model_name": "Danesmoor Utility", "model_qualifier": "15/19.ROO", "winter_efficiency_pct": 86.4, "summer_efficiency_pct": 74.7, "comparative_hot_water_efficiency_pct": 54.6, "output_kw_max": 19.0, "final_year_of_manufacture": 2008, "raw": ["001785", "000035", "0", "2020/Sep/02 14:13", "Worcester Heat Systems", "Worcester", "Danesmoor Utility", "15/19.ROO", "C14769/3-1", "1995", "2008", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "15", "19", "", "", "86.4", "74.7", "", "54.6", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.6", "87.9", "", "", "", "", "87.5"]} -{"pcdb_id": 1786, "brand_name": "Worcester", "model_name": "Danesmoor Utility", "model_qualifier": "15/19.OOO", "winter_efficiency_pct": 86.4, "summer_efficiency_pct": 74.7, "comparative_hot_water_efficiency_pct": 54.6, "output_kw_max": 19.0, "final_year_of_manufacture": 2008, "raw": ["001786", "000035", "0", "2020/Sep/02 14:13", "Worcester Heat Systems", "Worcester", "Danesmoor Utility", "15/19.OOO", "C14769/3-1", "1995", "2008", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "15", "19", "", "", "86.4", "74.7", "", "54.6", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.6", "87.9", "", "", "", "", "87.5"]} -{"pcdb_id": 1787, "brand_name": "Worcester", "model_name": "Danesmoor Utility", "model_qualifier": "20/25.ROO", "winter_efficiency_pct": 85.0, "summer_efficiency_pct": 73.3, "comparative_hot_water_efficiency_pct": 53.6, "output_kw_max": 25.0, "final_year_of_manufacture": 2002, "raw": ["001787", "000035", "0", "2020/Sep/02 14:13", "Worcester Heat Systems", "Worcester", "Danesmoor Utility", "20/25.ROO", "C14769/4-1", "1995", "2002", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "20", "25", "", "", "85.0", "73.3", "", "53.6", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "83.3", "86.8", "", "", "", "", "86.1"]} -{"pcdb_id": 1788, "brand_name": "Worcester", "model_name": "Danesmoor Utility", "model_qualifier": "20/25.OOO", "winter_efficiency_pct": 85.0, "summer_efficiency_pct": 73.3, "comparative_hot_water_efficiency_pct": 53.6, "output_kw_max": 25.0, "final_year_of_manufacture": 2002, "raw": ["001788", "000035", "0", "2020/Sep/02 14:13", "Worcester Heat Systems", "Worcester", "Danesmoor Utility", "20/25.OOO", "C14769/4-1", "1995", "2002", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "20", "25", "", "", "85.0", "73.3", "", "53.6", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "83.3", "86.8", "", "", "", "", "86.1"]} -{"pcdb_id": 1790, "brand_name": "Worcester", "model_name": "Bosch RX-2", "model_qualifier": "RSF", "winter_efficiency_pct": 84.8, "summer_efficiency_pct": 76.2, "comparative_hot_water_efficiency_pct": 53.6, "output_kw_max": 26.0, "final_year_of_manufacture": 2001, "raw": ["001790", "000035", "0", "2002/Aug/14 10:22", "Worcester Heat Systems", "Worcester", "Bosch RX-2", "RSF", "47 311 41", "1999", "2001", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "26", "26", "", "", "84.8", "76.2", "", "53.6", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "85.6", "90.1", "", "", "", "", "89.2"]} -{"pcdb_id": 1814, "brand_name": "Sime Heating Products (UK)", "model_name": "Sime", "model_qualifier": "Super 4", "winter_efficiency_pct": 79.1, "summer_efficiency_pct": 70.0, "comparative_hot_water_efficiency_pct": 42.8, "output_kw_max": 28.5, "final_year_of_manufacture": 2018, "raw": ["001814", "000213", "0", "2024/Jan/31 10:17", "Sime Heating Products (UK)", "Sime Heating Products (UK)", "Sime", "Super 4", "", "1995", "2018", "1", "1", "1", "2", "0", "", "", "1", "2", "2", "28.5", "28.5", "", "", "79.1", "70.0", "", "42.8", "", "2", "", "", "106", "1", "2", "150", "12.2", "2", "2", "0", "50", "0", "25", "2", "62", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.2", "77.5", "", "", "", "", "78.4"]} -{"pcdb_id": 1815, "brand_name": "Sime Heating Products (UK)", "model_name": "Format", "model_qualifier": "Friendly e", "winter_efficiency_pct": 80.2, "summer_efficiency_pct": 70.1, "comparative_hot_water_efficiency_pct": 49.3, "output_kw_max": 23.4, "final_year_of_manufacture": 2018, "raw": ["001815", "000213", "0", "2018/Mar/05 15:15", "Sime Heating Products (UK)", "Sime Heating Products (UK)", "Format", "Friendly e", "", "1998", "2018", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "23.4", "23.4", "", "", "80.2", "70.1", "", "49.3", "", "2", "", "", "104", "1", "2", "150", "12.5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.7", "80.1", "", "", "", "", "80.6"]} -{"pcdb_id": 1816, "brand_name": "Sime Heating Products (UK)", "model_name": "Format", "model_qualifier": "Friendly", "winter_efficiency_pct": 80.2, "summer_efficiency_pct": 70.1, "comparative_hot_water_efficiency_pct": 49.3, "output_kw_max": 23.4, "final_year_of_manufacture": 2018, "raw": ["001816", "000213", "0", "2018/Mar/05 15:15", "Sime Heating Products (UK)", "Sime Heating Products (UK)", "Format", "Friendly", "", "1998", "2018", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "23.4", "23.4", "", "", "80.2", "70.1", "", "49.3", "", "2", "", "", "104", "1", "2", "150", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.7", "80.1", "", "", "", "", "80.6"]} -{"pcdb_id": 1817, "brand_name": "Sime Heating Products (UK)", "model_name": "Format", "model_qualifier": "super 100", "winter_efficiency_pct": 79.5, "summer_efficiency_pct": 69.4, "comparative_hot_water_efficiency_pct": 48.8, "output_kw_max": 29.3, "final_year_of_manufacture": 2018, "raw": ["001817", "000213", "0", "2018/Mar/05 15:16", "Sime Heating Products (UK)", "Sime Heating Products (UK)", "Format", "super 100", "", "1998", "2018", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "29.3", "29.3", "", "", "79.5", "69.4", "", "48.8", "", "2", "", "", "104", "1", "2", "150", "12.5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.9", "78.6", "", "", "", "", "79.4"]} -{"pcdb_id": 1818, "brand_name": "Sime Heating Products (UK)", "model_name": "Murrelle", "model_qualifier": "", "winter_efficiency_pct": 76.2, "summer_efficiency_pct": 66.1, "comparative_hot_water_efficiency_pct": 46.5, "output_kw_max": 23.4, "final_year_of_manufacture": 2018, "raw": ["001818", "000213", "0", "2018/Mar/05 15:16", "Sime Heating Products (UK)", "Sime Heating Products (UK)", "Murrelle", "", "c/f", "1995", "2018", "1", "2", "1", "2", "0", "", "", "1", "1", "1", "23.4", "23.4", "", "", "76.2", "66.1", "", "46.5", "", "2", "", "", "104", "2", "2", "150", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.7", "80.1", "", "", "", "", "80.6"]} -{"pcdb_id": 1821, "brand_name": "Vaillant", "model_name": "Turbomax", "model_qualifier": "VUW 242 EH", "winter_efficiency_pct": 79.4, "summer_efficiency_pct": 69.3, "comparative_hot_water_efficiency_pct": 48.8, "output_kw_max": 24.0, "final_year_of_manufacture": 2000, "raw": ["001821", "000031", "0", "2006/Jan/17 12:55", "Vaillant", "Vaillant", "Turbomax", "VUW 242 EH", "VUW GB 242/1 EH", "1995", "2000", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "24.0", "24.0", "", "", "79.4", "69.3", "", "48.8", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.4", "78.8", "", "", "", "", "79.5"]} -{"pcdb_id": 1822, "brand_name": "Vaillant", "model_name": "Turbomax", "model_qualifier": "VUW 282 EH", "winter_efficiency_pct": 79.6, "summer_efficiency_pct": 69.5, "comparative_hot_water_efficiency_pct": 48.9, "output_kw_max": 28.0, "final_year_of_manufacture": 2000, "raw": ["001822", "000031", "0", "2006/Jan/17 12:55", "Vaillant", "Vaillant", "Turbomax", "VUW 282 EH", "VUW GB 282/1 EH", "1995", "2000", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "28.0", "28.0", "", "", "79.6", "69.5", "", "48.9", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.7", "78.8", "", "", "", "", "79.6"]} -{"pcdb_id": 1824, "brand_name": "Vaillant", "model_name": "Thermocompact", "model_qualifier": "VU 282 EH", "winter_efficiency_pct": 79.8, "summer_efficiency_pct": 69.1, "comparative_hot_water_efficiency_pct": 50.5, "output_kw_max": 24.0, "final_year_of_manufacture": 2000, "raw": ["001824", "000031", "0", "2012/Mar/27 10:12", "Vaillant", "Vaillant", "Thermocompact", "VU 282 EH", "VU GB 282/1 EH", "1996", "2000", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "24.0", "24.0", "", "", "79.8", "69.1", "", "50.5", "", "2", "", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.7", "78.8", "", "", "", "", "79.6"]} -{"pcdb_id": 1826, "brand_name": "Vaillant", "model_name": "Thermocompact", "model_qualifier": "VU 242 EH", "winter_efficiency_pct": 79.6, "summer_efficiency_pct": 68.9, "comparative_hot_water_efficiency_pct": 50.4, "output_kw_max": 24.0, "final_year_of_manufacture": 2000, "raw": ["001826", "000031", "0", "2012/Mar/27 10:12", "Vaillant", "Vaillant", "Thermocompact", "VU 242 EH", "VU GB 242/1 EH", "1996", "2000", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "24.0", "24.0", "", "", "79.6", "68.9", "", "50.4", "", "2", "", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.4", "78.8", "", "", "", "", "79.5"]} -{"pcdb_id": 1828, "brand_name": "Vaillant", "model_name": "Thermocompact", "model_qualifier": "VU 182 EH", "winter_efficiency_pct": 79.1, "summer_efficiency_pct": 68.4, "comparative_hot_water_efficiency_pct": 49.9, "output_kw_max": 18.0, "final_year_of_manufacture": 2000, "raw": ["001828", "000031", "0", "2012/Mar/27 10:12", "Vaillant", "Vaillant", "Thermocompact", "VU 182 EH", "VU GB 182/1 EH", "1996", "2000", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "18.0", "18.0", "", "", "79.1", "68.4", "", "49.9", "", "2", "", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.3", "77.8", "", "", "", "", "78.7"]} -{"pcdb_id": 1830, "brand_name": "Vaillant", "model_name": "Thermocompact", "model_qualifier": "VU 142 EH", "winter_efficiency_pct": 76.8, "summer_efficiency_pct": 66.1, "comparative_hot_water_efficiency_pct": 48.3, "output_kw_max": 14.0, "final_year_of_manufacture": 2000, "raw": ["001830", "000031", "0", "2012/Mar/27 10:12", "Vaillant", "Vaillant", "Thermocompact", "VU 142 EH", "VU GB 142/1EH", "1998", "2000", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "14.0", "14.0", "", "", "76.8", "66.1", "", "48.3", "", "2", "", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "79.9", "75.7", "", "", "", "", "76.5"]} -{"pcdb_id": 1832, "brand_name": "Vaillant", "model_name": "Ecomax", "model_qualifier": "VU 186 EH", "winter_efficiency_pct": 87.0, "summer_efficiency_pct": 78.0, "comparative_hot_water_efficiency_pct": 57.0, "output_kw_max": 17.2, "final_year_of_manufacture": 2000, "raw": ["001832", "000031", "0", "2012/Mar/27 10:12", "Vaillant", "Vaillant", "Ecomax", "VU 186 EH", "VU GB 186 EH", "1995", "2000", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "17.2", "17.2", "", "", "87.0", "78.0", "", "57.0", "", "2", "", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.6", "94.1", "", "", "", "", "93.0"]} -{"pcdb_id": 1834, "brand_name": "Vaillant", "model_name": "Ecomax", "model_qualifier": "VU 226 EH", "winter_efficiency_pct": 87.0, "summer_efficiency_pct": 78.0, "comparative_hot_water_efficiency_pct": 57.0, "output_kw_max": 21.3, "final_year_of_manufacture": 2000, "raw": ["001834", "000031", "0", "2012/Mar/27 10:12", "Vaillant", "Vaillant", "Ecomax", "VU 226 EH", "VU GB 226 EH", "1995", "2000", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "21.3", "21.3", "", "", "87.0", "78.0", "", "57.0", "", "2", "", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.5", "94.2", "", "", "", "", "93.1"]} -{"pcdb_id": 1838, "brand_name": "Vaillant", "model_name": "Ecomax", "model_qualifier": "828 E", "winter_efficiency_pct": 87.0, "summer_efficiency_pct": 78.4, "comparative_hot_water_efficiency_pct": 55.1, "output_kw_max": 21.5, "final_year_of_manufacture": 2000, "raw": ["001838", "000031", "0", "2006/Jan/17 12:55", "Vaillant", "Vaillant", "Ecomax", "828 E", "VUW GB 286E CH", "1999", "2000", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "21.5", "21.5", "", "", "87.0", "78.4", "", "55.1", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "84.9", "96.5", "", "", "", "", "94.3"]} -{"pcdb_id": 1839, "brand_name": "Vaillant", "model_name": "Ecomax", "model_qualifier": "824 E", "winter_efficiency_pct": 86.8, "summer_efficiency_pct": 78.2, "comparative_hot_water_efficiency_pct": 55.0, "output_kw_max": 17.7, "final_year_of_manufacture": 2000, "raw": ["001839", "000031", "0", "2006/Jan/17 12:55", "Vaillant", "Vaillant", "Ecomax", "824 E", "VUW GB 246E CH", "1999", "2000", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "17.7", "17.7", "", "", "86.8", "78.2", "", "55.0", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "84.7", "96.3", "", "", "", "", "94.1"]} -{"pcdb_id": 1840, "brand_name": "Baxi Heating", "model_name": "Barcelona", "model_qualifier": "", "winter_efficiency_pct": 87.6, "summer_efficiency_pct": 78.6, "comparative_hot_water_efficiency_pct": 57.4, "output_kw_max": 31.05, "final_year_of_manufacture": 2002, "raw": ["001840", "000005", "0", "2012/Mar/27 10:12", "Baxi Heating", "Baxi Heating", "Barcelona", "", "GC No 41-075-02", "1999", "2002", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "31.05", "31.05", "", "", "87.6", "78.6", "", "57.4", "", "2", "", "", "102", "1", "2", "80", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "91.0", "94.4", "", "", "", "", "93.8"]} -{"pcdb_id": 1841, "brand_name": "Baxi Heating", "model_name": "Bahama", "model_qualifier": "100", "winter_efficiency_pct": 80.4, "summer_efficiency_pct": 70.3, "comparative_hot_water_efficiency_pct": 49.5, "output_kw_max": 29.3, "final_year_of_manufacture": 2002, "raw": ["001841", "000005", "0", "2008/Jun/26 09:26", "Baxi Heating", "Baxi Heating", "Bahama", "100", "GC No 47-075-01", "1998", "2002", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "29.3", "29.3", "", "", "80.4", "70.3", "", "49.5", "", "2", "", "", "104", "1", "2", "200", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.0", "81.3", "", "", "", "", "81.4"]} -{"pcdb_id": 1842, "brand_name": "Baxi Heating", "model_name": "Bermuda", "model_qualifier": "45/4E", "winter_efficiency_pct": 77.7, "summer_efficiency_pct": 67.6, "comparative_hot_water_efficiency_pct": 49.4, "output_kw_max": 13.19, "final_year_of_manufacture": 2003, "raw": ["001842", "000005", "0", "2012/Mar/27 10:12", "Baxi Heating", "Baxi Heating", "Bermuda", "45/4E", "GC No 44-077-73", "1997", "2003", "1", "4", "1", "1", "0", "", "", "1", "1", "1", "10.26", "13.19", "", "", "77.7", "67.6", "", "49.4", "", "2", "", "", "101", "1", "1", "0", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.4", "79.2", "", "", "", "", "79.2"]} -{"pcdb_id": 1843, "brand_name": "Baxi Heating", "model_name": "Bermuda", "model_qualifier": "45/4M", "winter_efficiency_pct": 73.6, "summer_efficiency_pct": 63.5, "comparative_hot_water_efficiency_pct": 46.3, "output_kw_max": 13.19, "final_year_of_manufacture": 2002, "raw": ["001843", "000005", "0", "2012/Mar/27 10:12", "Baxi Heating", "Baxi Heating", "Bermuda", "45/4M", "GC No 44-077-71", "1996", "2002", "1", "4", "1", "1", "0", "", "", "1", "1", "1", "10.26", "13.19", "", "", "73.6", "63.5", "", "46.3", "", "2", "", "", "101", "2", "1", "0", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.4", "78.9", "", "", "", "", "79.0"]} -{"pcdb_id": 1844, "brand_name": "Baxi Heating", "model_name": "Bermuda", "model_qualifier": "57/4E", "winter_efficiency_pct": 76.7, "summer_efficiency_pct": 66.6, "comparative_hot_water_efficiency_pct": 48.6, "output_kw_max": 16.85, "final_year_of_manufacture": 2005, "raw": ["001844", "000005", "0", "2012/Mar/27 10:12", "Baxi Heating", "Baxi Heating", "Bermuda", "57/4E", "GC No 44-077-74", "1997", "2005", "1", "4", "1", "1", "0", "", "", "1", "1", "1", "13.19", "16.85", "", "", "76.7", "66.6", "", "48.6", "", "2", "", "", "101", "1", "1", "0", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "78.8", "77.8", "", "", "", "", "78.0"]} -{"pcdb_id": 1845, "brand_name": "Baxi Heating", "model_name": "Bermuda", "model_qualifier": "57/4M", "winter_efficiency_pct": 72.7, "summer_efficiency_pct": 62.6, "comparative_hot_water_efficiency_pct": 45.7, "output_kw_max": 16.85, "final_year_of_manufacture": 2002, "raw": ["001845", "000005", "0", "2012/Mar/27 10:12", "Baxi Heating", "Baxi Heating", "Bermuda", "57/4M", "GC No 44-077-72", "1996", "2002", "1", "4", "1", "1", "0", "", "", "1", "1", "1", "13.19", "16.85", "", "", "72.7", "62.6", "", "45.7", "", "2", "", "", "101", "2", "1", "0", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "78.8", "77.7", "", "", "", "", "77.9"]} -{"pcdb_id": 1846, "brand_name": "Baxi Heating", "model_name": "Solo PF 3", "model_qualifier": "30", "winter_efficiency_pct": 79.7, "summer_efficiency_pct": 69.6, "comparative_hot_water_efficiency_pct": 50.8, "output_kw_max": 8.9, "final_year_of_manufacture": 2001, "raw": ["001846", "000005", "0", "2012/Mar/27 10:12", "Baxi Heating", "Baxi Heating", "Solo PF 3", "30", "GC No 41-075-04", "1999", "2001", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "5.86", "8.9", "", "", "79.7", "69.6", "", "50.8", "", "2", "", "", "101", "1", "1", "90", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.7", "80.8", "", "", "", "", "81.0"]} -{"pcdb_id": 1847, "brand_name": "Baxi Heating", "model_name": "Solo PF 3", "model_qualifier": "40", "winter_efficiency_pct": 78.7, "summer_efficiency_pct": 68.6, "comparative_hot_water_efficiency_pct": 50.1, "output_kw_max": 11.72, "final_year_of_manufacture": 2001, "raw": ["001847", "000005", "0", "2012/Mar/27 10:12", "Baxi Heating", "Baxi Heating", "Solo PF 3", "40", "GC No 41-075-05", "1999", "2001", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "9.09", "11.72", "", "", "78.7", "68.6", "", "50.1", "", "2", "", "", "101", "1", "1", "90", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.2", "81.4", "", "", "", "", "80.9"]} -{"pcdb_id": 1848, "brand_name": "Baxi Heating", "model_name": "Solo PF 3", "model_qualifier": "50", "winter_efficiency_pct": 77.6, "summer_efficiency_pct": 67.5, "comparative_hot_water_efficiency_pct": 49.3, "output_kw_max": 14.65, "final_year_of_manufacture": 2001, "raw": ["001848", "000005", "0", "2012/Mar/27 10:12", "Baxi Heating", "Baxi Heating", "Solo PF 3", "50", "GC No 41-075-06", "1999", "2001", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "12.02", "14.65", "", "", "77.6", "67.5", "", "49.3", "", "2", "", "", "101", "1", "1", "90", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "78.9", "79.5", "", "", "", "", "79.4"]} -{"pcdb_id": 1849, "brand_name": "Baxi Heating", "model_name": "Solo PF 3", "model_qualifier": "60", "winter_efficiency_pct": 78.7, "summer_efficiency_pct": 68.6, "comparative_hot_water_efficiency_pct": 50.1, "output_kw_max": 17.58, "final_year_of_manufacture": 2001, "raw": ["001849", "000005", "0", "2012/Mar/27 10:12", "Baxi Heating", "Baxi Heating", "Solo PF 3", "60", "GC No 41-075-07", "1999", "2001", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "14.95", "17.58", "", "", "78.7", "68.6", "", "50.1", "", "2", "", "", "101", "1", "1", "90", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.9", "80.6", "", "", "", "", "80.5"]} -{"pcdb_id": 1850, "brand_name": "Baxi Heating", "model_name": "Solo PF 3", "model_qualifier": "70", "winter_efficiency_pct": 78.6, "summer_efficiency_pct": 68.5, "comparative_hot_water_efficiency_pct": 50.1, "output_kw_max": 20.5, "final_year_of_manufacture": 2001, "raw": ["001850", "000005", "0", "2012/Mar/27 10:12", "Baxi Heating", "Baxi Heating", "Solo PF 3", "70", "GC No 41-075-08", "1999", "2001", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "17.88", "20.5", "", "", "78.6", "68.5", "", "50.1", "", "2", "", "", "101", "1", "1", "90", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "80.0", "80.5", "", "", "", "", "80.4"]} -{"pcdb_id": 1851, "brand_name": "Baxi Heating", "model_name": "Solo PF 3", "model_qualifier": "80", "winter_efficiency_pct": 78.7, "summer_efficiency_pct": 68.6, "comparative_hot_water_efficiency_pct": 50.1, "output_kw_max": 23.45, "final_year_of_manufacture": 2001, "raw": ["001851", "000005", "0", "2012/Mar/27 10:12", "Baxi Heating", "Baxi Heating", "Solo PF 3", "80", "GC No 41-075-09", "1999", "2001", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "20.8", "23.45", "", "", "78.7", "68.6", "", "50.1", "", "2", "", "", "101", "1", "1", "90", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.9", "80.6", "", "", "", "", "80.5"]} -{"pcdb_id": 1852, "brand_name": "Baxi Heating", "model_name": "Bermuda Inset 2", "model_qualifier": "50/4", "winter_efficiency_pct": 72.9, "summer_efficiency_pct": 62.8, "comparative_hot_water_efficiency_pct": 45.9, "output_kw_max": 14.65, "final_year_of_manufacture": 2002, "raw": ["001852", "000005", "0", "2012/Mar/27 10:12", "Baxi Heating", "Baxi Heating", "Bermuda Inset 2", "50/4", "GC No 44-075-01", "1997", "2002", "1", "4", "1", "1", "0", "", "", "1", "1", "1", "11.72", "14.65", "", "", "72.9", "62.8", "", "45.9", "", "2", "", "", "101", "2", "1", "0", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "78.7", "78.3", "", "", "", "", "78.4"]} -{"pcdb_id": 1853, "brand_name": "Trianco", "model_name": "Eurostar", "model_qualifier": "50/65", "winter_efficiency_pct": 77.4, "summer_efficiency_pct": 67.3, "comparative_hot_water_efficiency_pct": 49.2, "output_kw_max": 19.0, "final_year_of_manufacture": 2003, "raw": ["001853", "000062", "0", "2012/Mar/27 10:12", "Trianco Redfyre", "Trianco", "Eurostar", "50/65", "13961/1", "1997", "2003", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "14.7", "19.0", "", "", "77.4", "67.3", "", "49.2", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.2", "78.8", "", "", "", "", "78.9"]} -{"pcdb_id": 1854, "brand_name": "Ferroli", "model_name": "Optima 201", "model_qualifier": "", "winter_efficiency_pct": 75.1, "summer_efficiency_pct": 65.0, "comparative_hot_water_efficiency_pct": 45.7, "output_kw_max": 23.3, "final_year_of_manufacture": 1997, "raw": ["001854", "000097", "0", "2006/Jan/17 12:55", "Ferroli SpA", "Ferroli", "Optima 201", "", "", "1996", "1997", "1", "2", "1", "2", "0", "", "", "1", "1", "1", "23.3", "23.3", "", "", "75.1", "65.0", "", "45.7", "", "2", "", "", "104", "2", "2", "", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.5", "79.1", "", "", "", "", "79.6"]} -{"pcdb_id": 1855, "brand_name": "Trianco", "model_name": "Eurostar", "model_qualifier": "190/240", "winter_efficiency_pct": 86.2, "summer_efficiency_pct": 74.5, "comparative_hot_water_efficiency_pct": 54.4, "output_kw_max": null, "final_year_of_manufacture": 2003, "raw": ["001855", "000062", "0", "2012/Mar/27 10:12", "Trianco Redfyre", "Trianco", "Eurostar", "190/240", "13961/6", "1998", "2003", "4", "1", "2", "1", "0", "", "", "1", "1", "1", "55.7", ">70kW", "", "", "86.2", "74.5", "", "54.4", "", "2", "", "", "201", "1", "1", "148", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.6", "86.1", "", "", "", "", "86.2"]} -{"pcdb_id": 1856, "brand_name": "Ferroli", "model_name": "Domina 80", "model_qualifier": "", "winter_efficiency_pct": 80.5, "summer_efficiency_pct": 70.4, "comparative_hot_water_efficiency_pct": 49.5, "output_kw_max": 23.8, "final_year_of_manufacture": 2006, "raw": ["001856", "000097", "0", "2009/Apr/28 16:22", "Ferroli SpA", "Ferroli", "Domina 80", "", "", "1997", "2006", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "23.8", "23.8", "", "", "80.5", "70.4", "", "49.5", "", "2", "", "", "104", "1", "2", "", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "83.1", "80.5", "", "", "", "", "81.0"]} -{"pcdb_id": 1857, "brand_name": "Trianco", "model_name": "Eurostar", "model_qualifier": "50/65 I.T.W.", "winter_efficiency_pct": 86.5, "summer_efficiency_pct": 74.8, "comparative_hot_water_efficiency_pct": 54.7, "output_kw_max": 19.0, "final_year_of_manufacture": 2004, "raw": ["001857", "000062", "0", "2012/Mar/27 10:12", "Trianco Redfyre", "Trianco", "Eurostar", "50/65 I.T.W.", "13961/11", "1998", "2004", "4", "2", "1", "1", "0", "", "", "1", "1", "1", "14.6", "19", "", "", "86.5", "74.8", "", "54.7", "", "2", "", "", "201", "1", "1", "148", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.9", "87.9", "", "", "", "", "87.5"]} -{"pcdb_id": 1858, "brand_name": "Ferroli", "model_name": "Modena 80", "model_qualifier": "", "winter_efficiency_pct": 80.5, "summer_efficiency_pct": 70.4, "comparative_hot_water_efficiency_pct": 49.5, "output_kw_max": 23.8, "final_year_of_manufacture": 2005, "raw": ["001858", "000097", "0", "2009/Apr/28 16:13", "Ferroli SpA", "Ferroli", "Modena 80", "", "", "1998", "2005", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "23.8", "23.8", "", "", "80.5", "70.4", "", "49.5", "", "2", "", "", "104", "1", "2", "", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "83.1", "80.5", "", "", "", "", "81.0"]} -{"pcdb_id": 1859, "brand_name": "Trianco", "model_name": "Eurostar", "model_qualifier": "90 Combi", "winter_efficiency_pct": 84.6, "summer_efficiency_pct": 76.5, "comparative_hot_water_efficiency_pct": 44.7, "output_kw_max": 27.5, "final_year_of_manufacture": 2003, "raw": ["001859", "000062", "0", "2024/Jan/31 10:17", "Trianco Redfyre", "Trianco", "Eurostar", "90 Combi", "12579/1", "1997", "2003", "4", "1", "2", "2", "0", "", "", "1", "1", "1", "27.5", "27.5", "", "", "84.6", "76.5", "", "44.7", "", "2", "", "", "203", "1", "1", "1.2", "5.5", "2", "1", "0", "69", "0", "25", "1", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.9", "88.8", "", "", "", "", "88.3"]} -{"pcdb_id": 1860, "brand_name": "Ferroli", "model_name": "Tempra", "model_qualifier": "", "winter_efficiency_pct": 78.4, "summer_efficiency_pct": 68.3, "comparative_hot_water_efficiency_pct": 49.9, "output_kw_max": 17.6, "final_year_of_manufacture": 2000, "raw": ["001860", "000097", "0", "2012/Mar/27 10:12", "Ferroli SpA", "Ferroli", "Tempra", "", "", "1999", "2000", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "14.4", "17.6", "", "", "78.4", "68.3", "", "49.9", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.1", "78.8", "", "", "", "", "79.3"]} -{"pcdb_id": 1861, "brand_name": "Ferroli", "model_name": "Optima 2001", "model_qualifier": "", "winter_efficiency_pct": 84.9, "summer_efficiency_pct": 76.3, "comparative_hot_water_efficiency_pct": 53.7, "output_kw_max": 22.6, "final_year_of_manufacture": 2000, "raw": ["001861", "000097", "0", "2006/Jan/17 12:55", "Ferroli SpA", "Ferroli", "Optima 2001", "", "", "1996", "2000", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "22.6", "22.6", "", "", "84.9", "76.3", "", "53.7", "", "2", "", "", "104", "1", "2", "", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "86.9", "89.5", "", "", "", "", "89.0"]} -{"pcdb_id": 1862, "brand_name": "Trianco", "model_name": "Eurostar", "model_qualifier": "130/150", "winter_efficiency_pct": 82.8, "summer_efficiency_pct": 71.1, "comparative_hot_water_efficiency_pct": 51.9, "output_kw_max": 44.0, "final_year_of_manufacture": 2003, "raw": ["001862", "000062", "0", "2012/Mar/27 10:12", "Trianco Redfyre", "Trianco", "Eurostar", "130/150", "13961/4.", "1997", "2003", "4", "1", "2", "1", "0", "", "", "1", "1", "2", "38.1", "44", "", "", "82.8", "71.1", "", "51.9", "", "2", "", "", "201", "1", "1", "148", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.4", "83.2", "", "", "", "", "83.0"]} -{"pcdb_id": 1863, "brand_name": "Ferroli", "model_name": "Sigma 30", "model_qualifier": "", "winter_efficiency_pct": 77.8, "summer_efficiency_pct": 67.7, "comparative_hot_water_efficiency_pct": 49.5, "output_kw_max": 8.8, "final_year_of_manufacture": 2001, "raw": ["001863", "000097", "0", "2012/Mar/27 10:12", "Ferroli SpA", "Ferroli", "Sigma 30", "", "", "1999", "2001", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "5.5", "8.8", "", "", "77.8", "67.7", "", "49.5", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "80.4", "78.5", "", "", "", "", "78.8"]} -{"pcdb_id": 1864, "brand_name": "Ferroli", "model_name": "Sigma 40", "model_qualifier": "", "winter_efficiency_pct": 78.6, "summer_efficiency_pct": 68.5, "comparative_hot_water_efficiency_pct": 50.0, "output_kw_max": 11.7, "final_year_of_manufacture": 2001, "raw": ["001864", "000097", "0", "2012/Mar/27 10:12", "Ferroli SpA", "Ferroli", "Sigma 40", "", "", "1999", "2001", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "8.5", "11.7", "", "", "78.6", "68.5", "", "50.0", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.9", "78.5", "", "", "", "", "79.1"]} -{"pcdb_id": 1865, "brand_name": "Ferroli", "model_name": "Sigma 50", "model_qualifier": "", "winter_efficiency_pct": 78.2, "summer_efficiency_pct": 68.1, "comparative_hot_water_efficiency_pct": 49.7, "output_kw_max": 14.7, "final_year_of_manufacture": 2001, "raw": ["001865", "000097", "0", "2012/Mar/27 10:12", "Ferroli SpA", "Ferroli", "Sigma 50", "", "", "1999", "2001", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "11.4", "14.7", "", "", "78.2", "68.1", "", "49.7", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "80.9", "78.7", "", "", "", "", "79.1"]} -{"pcdb_id": 1866, "brand_name": "Ferroli", "model_name": "Sigma 60", "model_qualifier": "", "winter_efficiency_pct": 78.4, "summer_efficiency_pct": 68.3, "comparative_hot_water_efficiency_pct": 49.9, "output_kw_max": 17.6, "final_year_of_manufacture": 2001, "raw": ["001866", "000097", "0", "2012/Mar/27 10:12", "Ferroli SpA", "Ferroli", "Sigma 60", "", "", "1999", "2001", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "14.4", "17.6", "", "", "78.4", "68.3", "", "49.9", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.1", "78.8", "", "", "", "", "79.3"]} -{"pcdb_id": 1867, "brand_name": "Trianco", "model_name": "Eurostar", "model_qualifier": "65 Combi", "winter_efficiency_pct": 80.3, "summer_efficiency_pct": 72.2, "comparative_hot_water_efficiency_pct": 43.0, "output_kw_max": 19.5, "final_year_of_manufacture": 2001, "raw": ["001867", "000062", "0", "2024/Jan/31 10:17", "Trianco Redfyre", "Trianco", "Eurostar", "65 Combi", "12579/1", "1997", "2001", "4", "1", "2", "2", "0", "", "", "1", "1", "1", "19.5", "19.5", "", "", "80.3", "72.2", "", "43.0", "", "2", "", "", "203", "1", "1", "1.2", "5.5", "2", "1", "0", "63", "0", "25", "1", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.4", "82.0", "", "", "", "", "82.1"]} -{"pcdb_id": 1868, "brand_name": "Trianco", "model_name": "Eurostar", "model_qualifier": "100/125", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 36.6, "final_year_of_manufacture": 2003, "raw": ["001868", "000062", "0", "2012/Mar/27 10:12", "Trianco Redfyre", "Trianco", "Eurostar", "100/125", "13961/3", "1997", "2003", "4", "1", "2", "1", "0", "", "", "1", "1", "1", "29.3", "36.6", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "148", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.4", "90.5", "", "", "", "", "89.7"]} -{"pcdb_id": 1869, "brand_name": "Trianco", "model_name": "Eurostar", "model_qualifier": "70/90", "winter_efficiency_pct": 86.5, "summer_efficiency_pct": 74.8, "comparative_hot_water_efficiency_pct": 54.7, "output_kw_max": 26.3, "final_year_of_manufacture": 2003, "raw": ["001869", "000062", "0", "2012/Mar/27 10:12", "Trianco Redfyre", "Trianco", "Eurostar", "70/90", "13961/2", "1997", "2003", "4", "1", "2", "1", "0", "", "", "1", "1", "1", "20.5", "26.3", "", "", "86.5", "74.8", "", "54.7", "", "2", "", "", "201", "1", "1", "148", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.9", "88.8", "", "", "", "", "88.3"]} -{"pcdb_id": 1870, "brand_name": "Trianco", "model_name": "Eurostar", "model_qualifier": "160/180", "winter_efficiency_pct": 86.3, "summer_efficiency_pct": 74.6, "comparative_hot_water_efficiency_pct": 54.5, "output_kw_max": 52.7, "final_year_of_manufacture": 2003, "raw": ["001870", "000062", "0", "2012/Mar/27 10:12", "Trianco Redfyre", "Trianco", "Eurostar", "160/180", "13161/5", "1998", "2003", "4", "1", "2", "1", "0", "", "", "1", "1", "1", "46.9", "52.7", "", "", "86.3", "74.6", "", "54.5", "", "2", "", "", "201", "1", "1", "148", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.8", "86.8", "", "", "", "", "86.6"]} -{"pcdb_id": 1871, "brand_name": "Trianco", "model_name": "Eurostar", "model_qualifier": "50/70 W.M", "winter_efficiency_pct": 84.5, "summer_efficiency_pct": 72.8, "comparative_hot_water_efficiency_pct": 53.2, "output_kw_max": 20.5, "final_year_of_manufacture": 2003, "raw": ["001871", "000062", "0", "2012/Mar/27 10:12", "Trianco Redfyre", "Trianco", "Eurostar", "50/70 W.M", "13961/12", "1996", "2003", "4", "2", "1", "1", "0", "", "", "1", "2", "1", "14.65", "20.5", "", "", "84.5", "72.8", "", "53.2", "", "2", "", "", "201", "1", "1", "148", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "83.7", "85.4", "", "", "", "", "85.0"]} -{"pcdb_id": 1872, "brand_name": "HRM Boilers", "model_name": "Wallstar", "model_qualifier": "12/14", "winter_efficiency_pct": 85.1, "summer_efficiency_pct": 73.4, "comparative_hot_water_efficiency_pct": 53.6, "output_kw_max": 15.35, "final_year_of_manufacture": 2006, "raw": ["001872", "000098", "0", "2012/Mar/27 10:12", "HRM Boilers", "HRM Boilers", "Wallstar", "12/14", "12/14", "1989", "2006", "4", "2", "2", "1", "0", "", "", "1", "2", "1", "12", "15.35", "", "", "85.1", "73.4", "", "53.6", "", "2", "", "", "201", "1", "1", "115", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "83.1", "88.0", "", "", "", "", "87.1"]} -{"pcdb_id": 1873, "brand_name": "HRM Boilers", "model_name": "Wallstar", "model_qualifier": "15/19", "winter_efficiency_pct": 82.9, "summer_efficiency_pct": 71.2, "comparative_hot_water_efficiency_pct": 52.0, "output_kw_max": 19.4, "final_year_of_manufacture": 2006, "raw": ["001873", "000098", "0", "2012/Mar/27 10:12", "HRM Boilers", "HRM Boilers", "Wallstar", "15/19", "15/19", "1995", "2006", "4", "2", "2", "1", "0", "", "", "1", "2", "1", "15", "19.4", "", "", "82.9", "71.2", "", "52.0", "", "2", "", "", "201", "1", "1", "115", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.1", "83.7", "", "", "", "", "83.4"]} -{"pcdb_id": 1874, "brand_name": "HRM Boilers", "model_name": "Wallstar", "model_qualifier": "20/24", "winter_efficiency_pct": 82.5, "summer_efficiency_pct": 70.8, "comparative_hot_water_efficiency_pct": 51.8, "output_kw_max": 24.65, "final_year_of_manufacture": 2006, "raw": ["001874", "000098", "0", "2012/Mar/27 10:12", "HRM Boilers", "HRM Boilers", "Wallstar", "20/24", "20/24", "1997", "2006", "4", "2", "2", "1", "0", "", "", "1", "2", "1", "20", "24.65", "", "", "82.5", "70.8", "", "51.8", "", "2", "", "", "201", "1", "1", "115", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "84.0", "81.1", "", "", "", "", "81.6"]} -{"pcdb_id": 1875, "brand_name": "HRM Boilers", "model_name": "Starflow", "model_qualifier": "50/85", "winter_efficiency_pct": 84.5, "summer_efficiency_pct": 72.8, "comparative_hot_water_efficiency_pct": 53.2, "output_kw_max": 23.45, "final_year_of_manufacture": 2006, "raw": ["001875", "000098", "0", "2012/Mar/27 10:12", "HRM Boilers", "HRM Boilers", "Starflow", "50/85", "50/85", "1997", "2006", "4", "1", "1", "1", "0", "", "", "1", "2", "1", "14.85", "23.45", "", "", "84.5", "72.8", "", "53.2", "", "2", "", "", "201", "1", "1", "115", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.7", "83.2", "", "", "", "", "83.7"]} -{"pcdb_id": 1876, "brand_name": "HRM Boilers", "model_name": "Starflow", "model_qualifier": "85/110", "winter_efficiency_pct": 81.1, "summer_efficiency_pct": 69.4, "comparative_hot_water_efficiency_pct": 50.7, "output_kw_max": 30.7, "final_year_of_manufacture": 2006, "raw": ["001876", "000098", "0", "2012/Mar/27 10:12", "HRM Boilers", "HRM Boilers", "Starflow", "85/110", "85/110", "1997", "2006", "4", "1", "1", "1", "0", "", "", "1", "2", "1", "24.91", "30.7", "", "", "81.1", "69.4", "", "50.7", "", "2", "", "", "201", "1", "1", "115", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.9", "79.2", "", "", "", "", "79.9"]} -{"pcdb_id": 1877, "brand_name": "Trianco", "model_name": "Eurostar Utility", "model_qualifier": "50/65 13961/1", "winter_efficiency_pct": 82.2, "summer_efficiency_pct": 70.5, "comparative_hot_water_efficiency_pct": 51.5, "output_kw_max": 19.0, "final_year_of_manufacture": 2003, "raw": ["001877", "000062", "0", "2012/Mar/27 10:12", "Trianco Redfyre", "Trianco", "Eurostar Utility", "50/65 13961/1", "", "1997", "2003", "4", "1", "2", "1", "0", "", "", "1", "1", "1", "14.65", "19.0", "", "", "82.2", "70.5", "", "51.5", "", "2", "", "", "201", "1", "1", "148", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.4", "82.0", "", "", "", "", "82.1"]} -{"pcdb_id": 1878, "brand_name": "Trianco", "model_name": "Eurostar", "model_qualifier": "50/65 System", "winter_efficiency_pct": 82.2, "summer_efficiency_pct": 70.5, "comparative_hot_water_efficiency_pct": 51.5, "output_kw_max": 19.0, "final_year_of_manufacture": 2003, "raw": ["001878", "000062", "0", "2012/Mar/27 10:12", "Trianco Redfyre", "Trianco", "Eurostar", "50/65 System", "13961/1", "1997", "2003", "4", "1", "2", "1", "0", "", "", "1", "1", "1", "14.65", "19.0", "", "", "82.2", "70.5", "", "51.5", "", "2", "", "", "201", "1", "1", "148", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.4", "82.0", "", "", "", "", "82.1"]} -{"pcdb_id": 1879, "brand_name": "Trianco", "model_name": "Eurostar", "model_qualifier": "70/90 Utility", "winter_efficiency_pct": 86.5, "summer_efficiency_pct": 74.8, "comparative_hot_water_efficiency_pct": 54.7, "output_kw_max": 26.3, "final_year_of_manufacture": 2003, "raw": ["001879", "000062", "0", "2012/Mar/27 10:12", "Trianco Redfyre", "Trianco", "Eurostar", "70/90 Utility", "13961/2", "1997", "2003", "4", "1", "2", "1", "0", "", "", "1", "1", "1", "20.5", "26.3", "", "", "86.5", "74.8", "", "54.7", "", "2", "", "", "201", "1", "1", "148", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.9", "88.8", "", "", "", "", "88.3"]} -{"pcdb_id": 1880, "brand_name": "Trianco", "model_name": "Eurostar", "model_qualifier": "70/90 System", "winter_efficiency_pct": 86.5, "summer_efficiency_pct": 74.8, "comparative_hot_water_efficiency_pct": 54.7, "output_kw_max": 26.3, "final_year_of_manufacture": 2003, "raw": ["001880", "000062", "0", "2012/Mar/27 10:12", "Trianco Redfyre", "Trianco", "Eurostar", "70/90 System", "13961/2", "1997", "2003", "4", "1", "2", "1", "0", "", "", "1", "1", "1", "20.5", "26.3", "", "", "86.5", "74.8", "", "54.7", "", "2", "", "", "201", "1", "1", "148", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.9", "88.8", "", "", "", "", "88.3"]} -{"pcdb_id": 1915, "brand_name": "Ravenheat", "model_name": "CSI 85", "model_qualifier": "", "winter_efficiency_pct": 86.3, "summer_efficiency_pct": 77.7, "comparative_hot_water_efficiency_pct": 54.7, "output_kw_max": 25.6, "final_year_of_manufacture": null, "raw": ["001915", "000026", "0", "2006/Jan/17 12:31", "Ravenheat", "Ravenheat", "CSI 85", "", "GC No. 47 581 19", "1998", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "25.6", "25.6", "", "", "86.3", "77.7", "", "54.7", "", "2", "", "", "104", "1", "2", "140", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.2", "92.9", "", "", "", "", "91.8"]} -{"pcdb_id": 1916, "brand_name": "Ravenheat", "model_name": "RSF 25/20E", "model_qualifier": "", "winter_efficiency_pct": 77.4, "summer_efficiency_pct": 67.3, "comparative_hot_water_efficiency_pct": 47.3, "output_kw_max": 29.0, "final_year_of_manufacture": 2001, "raw": ["001916", "000026", "0", "2006/Jan/17 12:55", "Ravenheat", "Ravenheat", "RSF 25/20E", "", "GC No. 47 581 09", "1996", "2001", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "29", "29", "", "", "77.4", "67.3", "", "47.3", "", "2", "", "", "104", "1", "2", "140", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "79.3", "77.8", "", "", "", "", "78.1"]} -{"pcdb_id": 1917, "brand_name": "Ravenheat", "model_name": "RSF 25/20ET", "model_qualifier": "", "winter_efficiency_pct": 77.4, "summer_efficiency_pct": 67.3, "comparative_hot_water_efficiency_pct": 47.3, "output_kw_max": 29.0, "final_year_of_manufacture": 2001, "raw": ["001917", "000026", "0", "2006/Jan/17 12:55", "Ravenheat", "Ravenheat", "RSF 25/20ET", "", "GC No. 47 581 08", "1996", "2001", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "29", "29", "", "", "77.4", "67.3", "", "47.3", "", "2", "", "", "104", "1", "2", "140", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "79.3", "77.8", "", "", "", "", "78.1"]} -{"pcdb_id": 1918, "brand_name": "Ravenheat", "model_name": "RSF 20/20E", "model_qualifier": "", "winter_efficiency_pct": 78.0, "summer_efficiency_pct": 67.9, "comparative_hot_water_efficiency_pct": 47.8, "output_kw_max": 24.1, "final_year_of_manufacture": 2001, "raw": ["001918", "000026", "0", "2006/Jan/17 12:55", "Ravenheat", "Ravenheat", "RSF 20/20E", "", "GC No. 47 581 07", "1996", "2001", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "24.1", "24.1", "", "", "78.0", "67.9", "", "47.8", "", "2", "", "", "104", "1", "2", "140", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "80.6", "77.8", "", "", "", "", "78.4"]} -{"pcdb_id": 1919, "brand_name": "Ravenheat", "model_name": "RSF 20/20ET", "model_qualifier": "", "winter_efficiency_pct": 78.0, "summer_efficiency_pct": 67.9, "comparative_hot_water_efficiency_pct": 47.8, "output_kw_max": 24.1, "final_year_of_manufacture": 2001, "raw": ["001919", "000026", "0", "2006/Jan/17 12:55", "Ravenheat", "Ravenheat", "RSF 20/20ET", "", "GC No. 47 581 06", "1996", "2001", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "24.1", "24.1", "", "", "78.0", "67.9", "", "47.8", "", "2", "", "", "104", "1", "2", "140", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "80.6", "77.8", "", "", "", "", "78.4"]} -{"pcdb_id": 1920, "brand_name": "Ravenheat", "model_name": "CSI 85T", "model_qualifier": "", "winter_efficiency_pct": 86.3, "summer_efficiency_pct": 77.7, "comparative_hot_water_efficiency_pct": 54.7, "output_kw_max": 25.6, "final_year_of_manufacture": null, "raw": ["001920", "000026", "0", "2006/Jan/17 12:31", "Ravenheat", "Ravenheat", "CSI 85T", "", "GC No. 47 581 20", "1998", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "25.6", "25.6", "", "", "86.3", "77.7", "", "54.7", "", "2", "", "", "104", "1", "2", "140", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.2", "92.9", "", "", "", "", "91.8"]} -{"pcdb_id": 1921, "brand_name": "Ravenheat", "model_name": "RSF 25/25E", "model_qualifier": "", "winter_efficiency_pct": 77.5, "summer_efficiency_pct": 67.4, "comparative_hot_water_efficiency_pct": 47.4, "output_kw_max": 29.0, "final_year_of_manufacture": 2001, "raw": ["001921", "000026", "0", "2006/Jan/17 12:55", "Ravenheat", "Ravenheat", "RSF 25/25E", "", "GC No. 47 581 11", "1996", "2001", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "29", "29", "", "", "77.5", "67.4", "", "47.4", "", "2", "", "", "104", "1", "2", "140", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "79.6", "77.8", "", "", "", "", "78.2"]} -{"pcdb_id": 1922, "brand_name": "Ravenheat", "model_name": "RSF 25/25ET", "model_qualifier": "", "winter_efficiency_pct": 77.5, "summer_efficiency_pct": 67.4, "comparative_hot_water_efficiency_pct": 47.4, "output_kw_max": 29.0, "final_year_of_manufacture": 2001, "raw": ["001922", "000026", "0", "2006/Jan/17 12:55", "Ravenheat", "Ravenheat", "RSF 25/25ET", "", "GC No. 47 581 10", "1996", "2001", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "29", "29", "", "", "77.5", "67.4", "", "47.4", "", "2", "", "", "104", "1", "2", "140", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "79.6", "77.8", "", "", "", "", "78.2"]} -{"pcdb_id": 1923, "brand_name": "Ravenheat", "model_name": "RSF 25/20E LPG", "model_qualifier": "", "winter_efficiency_pct": 79.1, "summer_efficiency_pct": 69.0, "comparative_hot_water_efficiency_pct": 48.5, "output_kw_max": 29.0, "final_year_of_manufacture": 2001, "raw": ["001923", "000026", "0", "2006/Jan/17 12:55", "Ravenheat", "Ravenheat", "RSF 25/20E LPG", "", "GC No. 47 581 15", "1996", "2001", "2", "2", "1", "2", "0", "", "", "1", "2", "2", "29", "29", "", "", "79.1", "69.0", "", "48.5", "", "2", "0", "", "104", "1", "2", "140", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.0", "79.6", "", "", "", "", "79.9"]} -{"pcdb_id": 1924, "brand_name": "Ravenheat", "model_name": "RSF 25/20ET LPG", "model_qualifier": "", "winter_efficiency_pct": 79.1, "summer_efficiency_pct": 69.0, "comparative_hot_water_efficiency_pct": 48.5, "output_kw_max": 29.0, "final_year_of_manufacture": 2001, "raw": ["001924", "000026", "0", "2006/Jan/17 12:55", "Ravenheat", "Ravenheat", "RSF 25/20ET LPG", "", "GC No. 47 581 14", "1996", "2001", "2", "2", "1", "2", "0", "", "", "1", "2", "2", "29", "29", "", "", "79.1", "69.0", "", "48.5", "", "2", "0", "", "104", "1", "2", "140", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.0", "79.6", "", "", "", "", "79.9"]} -{"pcdb_id": 1925, "brand_name": "Ravenheat", "model_name": "RSF 25/25ET LPG", "model_qualifier": "", "winter_efficiency_pct": 79.2, "summer_efficiency_pct": 69.1, "comparative_hot_water_efficiency_pct": 48.6, "output_kw_max": 29.0, "final_year_of_manufacture": 2001, "raw": ["001925", "000026", "0", "2006/Jan/17 12:55", "Ravenheat", "Ravenheat", "RSF 25/25ET LPG", "", "GC No. 47 581 16", "1996", "2001", "2", "2", "1", "2", "0", "", "", "1", "2", "2", "29", "29", "", "", "79.2", "69.1", "", "48.6", "", "2", "0", "", "104", "1", "2", "140", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.3", "79.6", "", "", "", "", "79.9"]} -{"pcdb_id": 1926, "brand_name": "Ravenheat", "model_name": "RSF 25/25E LPG", "model_qualifier": "", "winter_efficiency_pct": 79.2, "summer_efficiency_pct": 69.1, "comparative_hot_water_efficiency_pct": 48.6, "output_kw_max": 29.0, "final_year_of_manufacture": 2001, "raw": ["001926", "000026", "0", "2006/Jan/17 12:55", "Ravenheat", "Ravenheat", "RSF 25/25E LPG", "", "GC No. 47 581 17", "1996", "2001", "2", "2", "1", "2", "0", "", "", "1", "2", "2", "29", "29", "", "", "79.2", "69.1", "", "48.6", "", "2", "0", "", "104", "1", "2", "140", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.3", "79.6", "", "", "", "", "79.9"]} -{"pcdb_id": 1927, "brand_name": "Ravenheat", "model_name": "RSF 20/20E LPG", "model_qualifier": "", "winter_efficiency_pct": 79.8, "summer_efficiency_pct": 69.7, "comparative_hot_water_efficiency_pct": 49.0, "output_kw_max": 24.1, "final_year_of_manufacture": 2001, "raw": ["001927", "000026", "0", "2006/Jan/17 12:55", "Ravenheat", "Ravenheat", "RSF 20/20E LPG", "", "GC No. 47 581 13", "1996", "2001", "2", "2", "1", "2", "0", "", "", "1", "2", "2", "24.1", "24.1", "", "", "79.8", "69.7", "", "49.0", "", "2", "0", "", "104", "1", "2", "140", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.4", "79.6", "", "", "", "", "80.1"]} -{"pcdb_id": 1928, "brand_name": "Ravenheat", "model_name": "RSF 20/20ET LPG", "model_qualifier": "", "winter_efficiency_pct": 79.8, "summer_efficiency_pct": 69.7, "comparative_hot_water_efficiency_pct": 49.0, "output_kw_max": 24.1, "final_year_of_manufacture": 2001, "raw": ["001928", "000026", "0", "2006/Jan/17 12:55", "Ravenheat", "Ravenheat", "RSF 20/20ET LPG", "", "GC No. 47 581 12", "1996", "2001", "2", "2", "1", "2", "0", "", "", "1", "2", "2", "24.1", "24.1", "", "", "79.8", "69.7", "", "49.0", "", "2", "0", "", "104", "1", "2", "140", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.4", "79.6", "", "", "", "", "80.1"]} -{"pcdb_id": 1929, "brand_name": "Ravenheat", "model_name": "RSF 100ET LPG", "model_qualifier": "", "winter_efficiency_pct": 79.2, "summer_efficiency_pct": 69.1, "comparative_hot_water_efficiency_pct": 48.6, "output_kw_max": 29.0, "final_year_of_manufacture": 2001, "raw": ["001929", "000026", "0", "2006/Jan/17 12:55", "Ravenheat", "Ravenheat", "RSF 100ET LPG", "", "GC No. 47 581 26A", "1999", "2001", "2", "2", "1", "2", "0", "", "", "1", "2", "2", "29", "29", "", "", "79.2", "69.1", "", "48.6", "", "2", "0", "", "104", "1", "2", "140", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.3", "79.6", "", "", "", "", "79.9"]} -{"pcdb_id": 1930, "brand_name": "Ravenheat", "model_name": "RSF 100E LPG", "model_qualifier": "", "winter_efficiency_pct": 79.2, "summer_efficiency_pct": 69.1, "comparative_hot_water_efficiency_pct": 48.6, "output_kw_max": 29.0, "final_year_of_manufacture": 2001, "raw": ["001930", "000026", "0", "2006/Jan/17 12:55", "Ravenheat", "Ravenheat", "RSF 100E LPG", "", "GC No. 47 581 25A", "1999", "2001", "2", "2", "1", "2", "0", "", "", "1", "2", "2", "29.0", "29.0", "", "", "79.2", "69.1", "", "48.6", "", "2", "0", "", "104", "1", "2", "140", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.3", "79.6", "", "", "", "", "79.9"]} -{"pcdb_id": 1931, "brand_name": "Ravenheat", "model_name": "RSF 84E LPG", "model_qualifier": "", "winter_efficiency_pct": 79.8, "summer_efficiency_pct": 69.7, "comparative_hot_water_efficiency_pct": 49.0, "output_kw_max": 24.1, "final_year_of_manufacture": 2001, "raw": ["001931", "000026", "0", "2006/Jan/17 12:55", "Ravenheat", "Ravenheat", "RSF 84E LPG", "", "GC No. 47 581 27A", "1999", "2001", "2", "2", "1", "2", "0", "", "", "1", "2", "2", "24.1", "24.1", "", "", "79.8", "69.7", "", "49.0", "", "2", "0", "", "104", "1", "2", "140", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.4", "79.6", "", "", "", "", "80.1"]} -{"pcdb_id": 1932, "brand_name": "Ravenheat", "model_name": "RSF 84ET LPG", "model_qualifier": "", "winter_efficiency_pct": 79.8, "summer_efficiency_pct": 69.7, "comparative_hot_water_efficiency_pct": 49.0, "output_kw_max": 24.1, "final_year_of_manufacture": 2001, "raw": ["001932", "000026", "0", "2006/Jan/17 12:55", "Ravenheat", "Ravenheat", "RSF 84ET LPG", "", "GC No. 47 581 28A", "1999", "2001", "2", "2", "1", "2", "0", "", "", "1", "2", "2", "24.1", "24.1", "", "", "79.8", "69.7", "", "49.0", "", "2", "0", "", "104", "1", "2", "140", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.4", "79.6", "", "", "", "", "80.1"]} -{"pcdb_id": 1933, "brand_name": "Ravenheat", "model_name": "RSF 820/20", "model_qualifier": "", "winter_efficiency_pct": 75.4, "summer_efficiency_pct": 65.3, "comparative_hot_water_efficiency_pct": 45.9, "output_kw_max": 23.6, "final_year_of_manufacture": 2002, "raw": ["001933", "000026", "0", "2006/Jan/17 12:55", "Ravenheat", "Ravenheat", "RSF 820/20", "", "GC No. 47 581 01", "1997", "2002", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "23.6", "23.6", "", "", "75.4", "65.3", "", "45.9", "", "2", "", "", "104", "2", "2", "140", "20", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.3", "79.9", "", "", "", "", "80.2"]} -{"pcdb_id": 1934, "brand_name": "Ravenheat", "model_name": "RSF 820/20T", "model_qualifier": "", "winter_efficiency_pct": 75.4, "summer_efficiency_pct": 65.3, "comparative_hot_water_efficiency_pct": 45.9, "output_kw_max": 23.6, "final_year_of_manufacture": 2002, "raw": ["001934", "000026", "0", "2006/Jan/17 12:55", "Ravenheat", "Ravenheat", "RSF 820/20T", "", "GC No. 47 581 05", "1997", "2002", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "23.6", "23.6", "", "", "75.4", "65.3", "", "45.9", "", "2", "", "", "104", "2", "2", "140", "20", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.3", "79.9", "", "", "", "", "80.2"]} -{"pcdb_id": 1935, "brand_name": "Ravenheat", "model_name": "RSF 100E", "model_qualifier": "", "winter_efficiency_pct": 77.5, "summer_efficiency_pct": 67.4, "comparative_hot_water_efficiency_pct": 47.4, "output_kw_max": 29.0, "final_year_of_manufacture": 2001, "raw": ["001935", "000026", "0", "2006/Jan/17 12:55", "Ravenheat", "Ravenheat", "RSF 100E", "", "GC No. 47 581 25A", "1999", "2001", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "29.0", "29.0", "", "", "77.5", "67.4", "", "47.4", "", "2", "", "", "104", "1", "2", "140", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "79.6", "77.8", "", "", "", "", "78.2"]} -{"pcdb_id": 1936, "brand_name": "Ravenheat", "model_name": "RSF 100ET", "model_qualifier": "", "winter_efficiency_pct": 77.5, "summer_efficiency_pct": 67.4, "comparative_hot_water_efficiency_pct": 47.4, "output_kw_max": 29.0, "final_year_of_manufacture": 2001, "raw": ["001936", "000026", "0", "2006/Jan/17 12:55", "Ravenheat", "Ravenheat", "RSF 100ET", "", "GC No. 47 581 26A", "1999", "2001", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "29.0", "29.0", "", "", "77.5", "67.4", "", "47.4", "", "2", "", "", "104", "1", "2", "140", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "79.6", "77.8", "", "", "", "", "78.2"]} -{"pcdb_id": 1937, "brand_name": "Ravenheat", "model_name": "CSI 85T LPG", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 56.1, "output_kw_max": 25.6, "final_year_of_manufacture": null, "raw": ["001937", "000026", "0", "2006/Jan/17 12:31", "Ravenheat", "Ravenheat", "CSI 85T LPG", "", "GC No. 47 581 24", "1998", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "25.6", "25.6", "", "", "88.3", "79.7", "", "56.1", "", "2", "0", "", "104", "1", "2", "140", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.2", "95.0", "", "", "", "", "93.9"]} -{"pcdb_id": 1938, "brand_name": "Ravenheat", "model_name": "CSI 85 LPG", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 56.1, "output_kw_max": 25.6, "final_year_of_manufacture": null, "raw": ["001938", "000026", "0", "2006/Jan/17 12:31", "Ravenheat", "Ravenheat", "CSI 85 LPG", "", "GC No. 47 581 23", "1998", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "25.6", "25.6", "", "", "88.3", "79.7", "", "56.1", "", "2", "0", "", "104", "1", "2", "140", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.2", "95.0", "", "", "", "", "93.9"]} -{"pcdb_id": 1939, "brand_name": "Ravenheat", "model_name": "RSF 84E", "model_qualifier": "", "winter_efficiency_pct": 78.0, "summer_efficiency_pct": 67.9, "comparative_hot_water_efficiency_pct": 47.8, "output_kw_max": 24.1, "final_year_of_manufacture": 2001, "raw": ["001939", "000026", "0", "2006/Jan/17 12:55", "Ravenheat", "Ravenheat", "RSF 84E", "", "GC No. 47 581 27A", "1999", "2001", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "24.1", "24.1", "", "", "78.0", "67.9", "", "47.8", "", "2", "", "", "104", "1", "2", "140", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "80.6", "77.8", "", "", "", "", "78.4"]} -{"pcdb_id": 1940, "brand_name": "Ravenheat", "model_name": "RSF 84 ET", "model_qualifier": "", "winter_efficiency_pct": 78.0, "summer_efficiency_pct": 67.9, "comparative_hot_water_efficiency_pct": 47.8, "output_kw_max": 24.1, "final_year_of_manufacture": 2001, "raw": ["001940", "000026", "0", "2006/Jan/17 12:55", "Ravenheat", "Ravenheat", "RSF 84 ET", "", "GC No. 47 581 28A", "1999", "2001", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "24.1", "24.1", "", "", "78.0", "67.9", "", "47.8", "", "2", "", "", "104", "1", "2", "140", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "80.6", "77.8", "", "", "", "", "78.4"]} -{"pcdb_id": 1941, "brand_name": "Ravenheat", "model_name": "RSF 82 E", "model_qualifier": "", "winter_efficiency_pct": 79.4, "summer_efficiency_pct": 69.3, "comparative_hot_water_efficiency_pct": 48.7, "output_kw_max": 23.6, "final_year_of_manufacture": null, "raw": ["001941", "000026", "0", "2006/Jan/17 12:31", "Ravenheat", "Ravenheat", "RSF 82 E", "", "GC No. 47 581 18", "1998", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "23.6", "23.6", "", "", "79.4", "69.3", "", "48.7", "", "2", "", "", "104", "1", "2", "140", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.3", "79.9", "", "", "", "", "80.2"]} -{"pcdb_id": 1942, "brand_name": "Ravenheat", "model_name": "RSF 82 ET", "model_qualifier": "", "winter_efficiency_pct": 79.4, "summer_efficiency_pct": 69.3, "comparative_hot_water_efficiency_pct": 48.7, "output_kw_max": 23.6, "final_year_of_manufacture": null, "raw": ["001942", "000026", "0", "2006/Jan/17 12:31", "Ravenheat", "Ravenheat", "RSF 82 ET", "", "GC No. 47 581 04", "1998", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "23.6", "23.6", "", "", "79.4", "69.3", "", "48.7", "", "2", "", "", "104", "1", "2", "140", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.3", "79.9", "", "", "", "", "80.2"]} -{"pcdb_id": 1943, "brand_name": "Ravenheat", "model_name": "CSI System T", "model_qualifier": "", "winter_efficiency_pct": 86.3, "summer_efficiency_pct": 77.3, "comparative_hot_water_efficiency_pct": 56.5, "output_kw_max": 25.6, "final_year_of_manufacture": null, "raw": ["001943", "000026", "0", "2012/Mar/27 10:12", "Ravenheat", "Ravenheat", "CSI System T", "", "GC No. 5158102CSI", "1999", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "25.6", "25.6", "", "", "86.3", "77.3", "", "56.5", "", "2", "", "", "102", "1", "2", "140", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.2", "92.9", "", "", "", "", "91.8"]} -{"pcdb_id": 1944, "brand_name": "Ravenheat", "model_name": "CSI System", "model_qualifier": "", "winter_efficiency_pct": 86.3, "summer_efficiency_pct": 77.3, "comparative_hot_water_efficiency_pct": 56.5, "output_kw_max": 25.6, "final_year_of_manufacture": null, "raw": ["001944", "000026", "0", "2012/Mar/27 10:12", "Ravenheat", "Ravenheat", "CSI System", "", "GC No. 4158101CSI", "1999", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "25.6", "25.6", "", "", "86.3", "77.3", "", "56.5", "", "2", "", "", "102", "1", "2", "140", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.2", "92.9", "", "", "", "", "91.8"]} -{"pcdb_id": 1945, "brand_name": "Ravenheat", "model_name": "CSI Primary LPG", "model_qualifier": "", "winter_efficiency_pct": 86.9, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 25.6, "final_year_of_manufacture": null, "raw": ["001945", "000026", "0", "2012/Mar/27 10:12", "Ravenheat", "Ravenheat", "CSI Primary LPG", "", "GC No. 4158106CSI", "1999", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "11.7", "25.6", "", "", "86.9", "79.3", "", "57.9", "", "2", "0", "", "101", "1", "1", "60", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "89.2", "95.0", "", "", "", "", "93.9"]} -{"pcdb_id": 1946, "brand_name": "Ravenheat", "model_name": "CSI Primary", "model_qualifier": "", "winter_efficiency_pct": 84.9, "summer_efficiency_pct": 77.3, "comparative_hot_water_efficiency_pct": 56.5, "output_kw_max": 25.6, "final_year_of_manufacture": null, "raw": ["001946", "000026", "0", "2012/Mar/27 10:12", "Ravenheat", "Ravenheat", "CSI Primary", "", "GC No. 4158105CSI", "1999", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "11.7", "25.6", "", "", "84.9", "77.3", "", "56.5", "", "2", "", "", "101", "1", "1", "60", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "87.2", "92.9", "", "", "", "", "91.8"]} -{"pcdb_id": 1947, "brand_name": "Ravenheat", "model_name": "CSI System T", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 25.6, "final_year_of_manufacture": null, "raw": ["001947", "000026", "0", "2012/Mar/27 10:12", "Ravenheat", "Ravenheat", "CSI System T", "", "GC No. 4158104CSI(T)", "1999", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "25.6", "25.6", "", "", "88.3", "79.3", "", "57.9", "", "2", "0", "", "102", "1", "2", "140", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.2", "95.0", "", "", "", "", "93.9"]} -{"pcdb_id": 1948, "brand_name": "Ravenheat", "model_name": "CSI System", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 25.6, "final_year_of_manufacture": null, "raw": ["001948", "000026", "0", "2012/Mar/27 10:12", "Ravenheat", "Ravenheat", "CSI System", "", "GC No. 4158103CSI", "1999", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "25.6", "25.6", "", "", "88.3", "79.3", "", "57.9", "", "2", "0", "", "102", "1", "2", "140", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.2", "95.0", "", "", "", "", "93.9"]} -{"pcdb_id": 1949, "brand_name": "Potterton Myson", "model_name": "Combi 100", "model_qualifier": "", "winter_efficiency_pct": 79.7, "summer_efficiency_pct": 69.6, "comparative_hot_water_efficiency_pct": 48.9, "output_kw_max": 29.0, "final_year_of_manufacture": 2001, "raw": ["001949", "000005", "0", "2006/Jan/17 12:55", "Potterton Myson", "Potterton Myson", "Combi 100", "", "LRR", "1999", "2001", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "29.0", "29.0", "", "", "79.7", "69.6", "", "48.9", "", "2", "", "", "104", "1", "2", "200", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.2", "80.5", "", "", "", "", "80.7"]} -{"pcdb_id": 1951, "brand_name": "Potterton Myson", "model_name": "Envoy 30", "model_qualifier": "", "winter_efficiency_pct": 85.6, "summer_efficiency_pct": 78.0, "comparative_hot_water_efficiency_pct": 57.0, "output_kw_max": 9.7, "final_year_of_manufacture": 2000, "raw": ["001951", "000005", "0", "2012/Mar/27 10:12", "Potterton Myson", "Potterton Myson", "Envoy 30", "", "HKA", "1995", "2000", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "9.7", "9.7", "", "", "85.6", "78.0", "", "57.0", "", "2", "", "", "101", "1", "1", "80", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "87.5", "94.5", "", "", "", "", "93.2"]} -{"pcdb_id": 1952, "brand_name": "Potterton Myson", "model_name": "Envoy 40", "model_qualifier": "", "winter_efficiency_pct": 85.5, "summer_efficiency_pct": 77.9, "comparative_hot_water_efficiency_pct": 56.9, "output_kw_max": 12.8, "final_year_of_manufacture": 2000, "raw": ["001952", "000005", "0", "2012/Mar/27 10:12", "Potterton Myson", "Potterton Myson", "Envoy 40", "", "HKB", "1995", "2000", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "12.8", "12.8", "", "", "85.5", "77.9", "", "56.9", "", "2", "", "", "101", "1", "1", "80", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "87.8", "94.0", "", "", "", "", "92.8"]} -{"pcdb_id": 1953, "brand_name": "Potterton Myson", "model_name": "Envoy 50", "model_qualifier": "", "winter_efficiency_pct": 85.5, "summer_efficiency_pct": 77.9, "comparative_hot_water_efficiency_pct": 56.9, "output_kw_max": 16.1, "final_year_of_manufacture": 2000, "raw": ["001953", "000005", "0", "2012/Mar/27 10:12", "Potterton Myson", "Potterton Myson", "Envoy 50", "", "HKC", "1995", "2000", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "16.1", "16.1", "", "", "85.5", "77.9", "", "56.9", "", "2", "", "", "101", "1", "1", "80", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "88.0", "94.0", "", "", "", "", "92.8"]} -{"pcdb_id": 1954, "brand_name": "Potterton Myson", "model_name": "Envoy 60", "model_qualifier": "", "winter_efficiency_pct": 85.2, "summer_efficiency_pct": 77.6, "comparative_hot_water_efficiency_pct": 56.7, "output_kw_max": 19.0, "final_year_of_manufacture": 2000, "raw": ["001954", "000005", "0", "2012/Mar/27 10:12", "Potterton Myson", "Potterton Myson", "Envoy 60", "", "HKD", "1995", "2000", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "19.0", "19.0", "", "", "85.2", "77.6", "", "56.7", "", "2", "", "", "101", "1", "1", "80", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "86.8", "93.8", "", "", "", "", "92.5"]} -{"pcdb_id": 1955, "brand_name": "Potterton Myson", "model_name": "Envoy 80", "model_qualifier": "", "winter_efficiency_pct": 85.1, "summer_efficiency_pct": 77.5, "comparative_hot_water_efficiency_pct": 56.6, "output_kw_max": 25.0, "final_year_of_manufacture": 2000, "raw": ["001955", "000005", "0", "2012/Mar/27 10:12", "Potterton Myson", "Potterton Myson", "Envoy 80", "", "HKE", "1995", "2000", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "25.0", "25.0", "", "", "85.1", "77.5", "", "56.6", "", "2", "", "", "101", "1", "1", "80", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "87.4", "93.3", "", "", "", "", "92.2"]} -{"pcdb_id": 1964, "brand_name": "Potterton", "model_name": "Profile", "model_qualifier": "40e", "winter_efficiency_pct": 72.7, "summer_efficiency_pct": 62.6, "comparative_hot_water_efficiency_pct": 45.7, "output_kw_max": 11.72, "final_year_of_manufacture": 2001, "raw": ["001964", "000005", "0", "2012/Mar/27 10:12", "Potterton Myson", "Potterton", "Profile", "40e", "HBS", "1988", "2001", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "8.79", "11.72", "", "", "72.7", "62.6", "", "45.7", "", "2", "", "", "101", "1", "1", "80", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "74.9", "73.7", "", "", "", "", "73.9"]} -{"pcdb_id": 1965, "brand_name": "Potterton", "model_name": "Profile", "model_qualifier": "50e", "winter_efficiency_pct": 76.3, "summer_efficiency_pct": 66.2, "comparative_hot_water_efficiency_pct": 48.4, "output_kw_max": 14.65, "final_year_of_manufacture": 2001, "raw": ["001965", "000005", "0", "2012/Mar/27 10:12", "Potterton Myson", "Potterton", "Profile", "50e", "HBT", "1988", "2001", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "11.72", "14.65", "", "", "76.3", "66.2", "", "48.4", "", "2", "", "", "101", "1", "1", "80", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "78.6", "77.2", "", "", "", "", "77.5"]} -{"pcdb_id": 1966, "brand_name": "Potterton", "model_name": "Profile", "model_qualifier": "60e", "winter_efficiency_pct": 76.0, "summer_efficiency_pct": 65.9, "comparative_hot_water_efficiency_pct": 48.2, "output_kw_max": 17.58, "final_year_of_manufacture": 2001, "raw": ["001966", "000005", "0", "2012/Mar/27 10:12", "Potterton Myson", "Potterton", "Profile", "60e", "HBU", "1988", "2001", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "14.65", "17.58", "", "", "76.0", "65.9", "", "48.2", "", "2", "", "", "101", "1", "1", "80", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "78.3", "76.9", "", "", "", "", "77.2"]} -{"pcdb_id": 1967, "brand_name": "Potterton", "model_name": "Profile", "model_qualifier": "80e", "winter_efficiency_pct": 75.3, "summer_efficiency_pct": 65.2, "comparative_hot_water_efficiency_pct": 47.6, "output_kw_max": 23.45, "final_year_of_manufacture": 2001, "raw": ["001967", "000005", "0", "2012/Mar/27 10:12", "Potterton Myson", "Potterton", "Profile", "80e", "HBV", "1988", "2001", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "17.58", "23.45", "", "", "75.3", "65.2", "", "47.6", "", "2", "", "", "101", "1", "1", "80", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "77.4", "76.4", "", "", "", "", "76.6"]} -{"pcdb_id": 1968, "brand_name": "Potterton", "model_name": "Profile", "model_qualifier": "100e", "winter_efficiency_pct": 74.8, "summer_efficiency_pct": 64.7, "comparative_hot_water_efficiency_pct": 47.3, "output_kw_max": 29.3, "final_year_of_manufacture": 2001, "raw": ["001968", "000005", "0", "2012/Mar/27 10:12", "Potterton Myson", "Potterton", "Profile", "100e", "HHF", "1988", "2001", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "23.5", "29.3", "", "", "74.8", "64.7", "", "47.3", "", "2", "", "", "101", "1", "1", "80", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "76.9", "75.9", "", "", "", "", "76.1"]} -{"pcdb_id": 1973, "brand_name": "Potterton Myson", "model_name": "British Gas 30F2", "model_qualifier": "", "winter_efficiency_pct": 76.1, "summer_efficiency_pct": 66.0, "comparative_hot_water_efficiency_pct": 48.2, "output_kw_max": 8.79, "final_year_of_manufacture": 2001, "raw": ["001973", "000005", "0", "2012/Mar/27 10:12", "Potterton Myson", "Potterton Myson", "British Gas 30F2", "", "LRV", "1999", "2001", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "5.86", "8.79", "", "", "76.1", "66.0", "", "48.2", "", "2", "", "", "101", "1", "1", "80", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "78.6", "76.8", "", "", "", "", "77.1"]} -{"pcdb_id": 1974, "brand_name": "Potterton Myson", "model_name": "British Gas 40F2", "model_qualifier": "", "winter_efficiency_pct": 77.2, "summer_efficiency_pct": 67.1, "comparative_hot_water_efficiency_pct": 49.0, "output_kw_max": 11.72, "final_year_of_manufacture": 2001, "raw": ["001974", "000005", "0", "2012/Mar/27 10:12", "Potterton Myson", "Potterton Myson", "British Gas 40F2", "", "LRW", "1999", "2001", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "8.79", "11.72", "", "", "77.2", "67.1", "", "49.0", "", "2", "", "", "101", "1", "1", "80", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.6", "78.0", "", "", "", "", "78.3"]} -{"pcdb_id": 1975, "brand_name": "Potterton Myson", "model_name": "British Gas 50F2", "model_qualifier": "", "winter_efficiency_pct": 77.6, "summer_efficiency_pct": 67.5, "comparative_hot_water_efficiency_pct": 49.3, "output_kw_max": 14.65, "final_year_of_manufacture": 2001, "raw": ["001975", "000005", "0", "2012/Mar/27 10:12", "Potterton Myson", "Potterton Myson", "British Gas 50F2", "", "LRX", "1999", "2001", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "11.72", "14.65", "", "", "77.6", "67.5", "", "49.3", "", "2", "", "", "101", "1", "1", "80", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "80.2", "78.3", "", "", "", "", "78.7"]} -{"pcdb_id": 1976, "brand_name": "Potterton Myson", "model_name": "British Gas 60F2", "model_qualifier": "", "winter_efficiency_pct": 77.6, "summer_efficiency_pct": 67.5, "comparative_hot_water_efficiency_pct": 49.3, "output_kw_max": 17.58, "final_year_of_manufacture": 2001, "raw": ["001976", "000005", "0", "2012/Mar/27 10:12", "Potterton Myson", "Potterton Myson", "British Gas 60F2", "", "LRY", "1999", "2001", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "14.65", "17.58", "", "", "77.6", "67.5", "", "49.3", "", "2", "", "", "101", "1", "1", "80", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "80.0", "78.4", "", "", "", "", "78.7"]} -{"pcdb_id": 1977, "brand_name": "Potterton Myson", "model_name": "British Gas 80F2", "model_qualifier": "", "winter_efficiency_pct": 76.8, "summer_efficiency_pct": 66.7, "comparative_hot_water_efficiency_pct": 48.7, "output_kw_max": 23.45, "final_year_of_manufacture": 2001, "raw": ["001977", "000005", "0", "2012/Mar/27 10:12", "Potterton Myson", "Potterton Myson", "British Gas 80F2", "", "LSA", "1999", "2001", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "17.58", "23.45", "", "", "76.8", "66.7", "", "48.7", "", "2", "", "", "101", "1", "1", "80", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.2", "77.6", "", "", "", "", "77.9"]} -{"pcdb_id": 1978, "brand_name": "Powermax", "model_name": "185", "model_qualifier": "", "winter_efficiency_pct": 83.5, "summer_efficiency_pct": 81.6, "comparative_hot_water_efficiency_pct": 62.0, "output_kw_max": 18.3, "final_year_of_manufacture": null, "raw": ["001978", "000099", "0", "2002/Aug/14 10:19", "Range Powermax", "Powermax", "185", "", "87AQ149", "1993", "current", "1", "1", "1", "3", "0", "", "", "1", "2", "2", "18.3", "18.3", "", "", "83.5", "81.6", "", "62.0", "", "2", "", "", "107", "1", "1", "140", "0", "3", "", "0", "150", "0", "50", "5", "80", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.8", "85.0", "", "", "", "", "84.6"]} -{"pcdb_id": 1979, "brand_name": "Potterton Myson", "model_name": "Kingfisher Mf RS 100", "model_qualifier": "", "winter_efficiency_pct": 77.8, "summer_efficiency_pct": 67.7, "comparative_hot_water_efficiency_pct": 49.5, "output_kw_max": 29.31, "final_year_of_manufacture": 2001, "raw": ["001979", "000005", "0", "2012/Mar/27 10:12", "Potterton Myson", "Potterton Myson", "Kingfisher Mf RS 100", "", "HLX", "1997", "2001", "1", "1", "1", "1", "0", "", "", "1", "2", "2", "26.38", "29.31", "", "", "77.8", "67.7", "", "49.5", "", "2", "", "", "101", "1", "1", "80", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.2", "79.6", "", "", "", "", "79.6"]} -{"pcdb_id": 1980, "brand_name": "Powermax", "model_name": "155", "model_qualifier": "", "winter_efficiency_pct": 81.2, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 63.9, "output_kw_max": 15.5, "final_year_of_manufacture": null, "raw": ["001980", "000099", "0", "2002/Aug/14 10:05", "Range Powermax", "Powermax", "155", "", "87AQ147", "1996", "current", "1", "1", "1", "3", "0", "", "", "1", "2", "2", "15.5", "15.5", "", "", "81.2", "79.3", "", "63.9", "", "2", "", "", "107", "1", "1", "140", "0", "3", "", "0", "100", "0", "50", "5", "80", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "80.7", "82.0", "", "", "", "", "81.8"]} -{"pcdb_id": 1981, "brand_name": "Potterton Myson", "model_name": "Kingfisher Mf RS 90", "model_qualifier": "", "winter_efficiency_pct": 78.5, "summer_efficiency_pct": 68.4, "comparative_hot_water_efficiency_pct": 49.9, "output_kw_max": 26.38, "final_year_of_manufacture": 2001, "raw": ["001981", "000005", "0", "2012/Mar/27 10:12", "Potterton Myson", "Potterton Myson", "Kingfisher Mf RS 90", "", "HLW", "1997", "2001", "1", "1", "1", "1", "0", "", "", "1", "2", "2", "23.45", "26.38", "", "", "78.5", "68.4", "", "49.9", "", "2", "", "", "101", "1", "1", "80", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.8", "80.3", "", "", "", "", "80.2"]} -{"pcdb_id": 1983, "brand_name": "Powermax", "model_name": "140", "model_qualifier": "", "winter_efficiency_pct": 82.3, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 66.6, "output_kw_max": 14.0, "final_year_of_manufacture": null, "raw": ["001983", "000099", "0", "2002/Aug/14 10:05", "Range Powermax", "Powermax", "140", "", "87AU97", "1999", "current", "1", "1", "1", "3", "0", "", "", "1", "2", "2", "14", "14", "", "", "82.3", "80.5", "", "66.6", "", "2", "", "", "107", "1", "1", "140", "0", "3", "", "0", "80", "0", "50", "5", "80", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.9", "82.0", "", "", "", "", "82.2"]} -{"pcdb_id": 1984, "brand_name": "Potterton Myson", "model_name": "Kingfisher Mf RS 80", "model_qualifier": "", "winter_efficiency_pct": 77.8, "summer_efficiency_pct": 67.7, "comparative_hot_water_efficiency_pct": 49.5, "output_kw_max": 23.45, "final_year_of_manufacture": 2001, "raw": ["001984", "000005", "0", "2012/Mar/27 10:12", "Potterton Myson", "Potterton Myson", "Kingfisher Mf RS 80", "", "HLV", "1997", "2001", "1", "1", "1", "1", "0", "", "", "1", "2", "2", "20.52", "23.45", "", "", "77.8", "67.7", "", "49.5", "", "2", "", "", "101", "1", "1", "80", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.4", "79.5", "", "", "", "", "79.5"]} -{"pcdb_id": 1985, "brand_name": "Potterton Myson", "model_name": "Kingfisher Mf RS 70", "model_qualifier": "", "winter_efficiency_pct": 77.4, "summer_efficiency_pct": 67.3, "comparative_hot_water_efficiency_pct": 49.2, "output_kw_max": 20.52, "final_year_of_manufacture": 2001, "raw": ["001985", "000005", "0", "2012/Mar/27 10:12", "Potterton Myson", "Potterton Myson", "Kingfisher Mf RS 70", "", "HLU", "1997", "2001", "1", "1", "1", "1", "0", "", "", "1", "2", "2", "17.58", "20.52", "", "", "77.4", "67.3", "", "49.2", "", "2", "", "", "101", "1", "1", "80", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "78.8", "79.2", "", "", "", "", "79.1"]} -{"pcdb_id": 1986, "brand_name": "Potterton Myson", "model_name": "Kingfisher Mf RS 60", "model_qualifier": "", "winter_efficiency_pct": 77.7, "summer_efficiency_pct": 67.6, "comparative_hot_water_efficiency_pct": 49.4, "output_kw_max": 17.58, "final_year_of_manufacture": 2001, "raw": ["001986", "000005", "0", "2012/Mar/27 10:12", "Potterton Myson", "Potterton Myson", "Kingfisher Mf RS 60", "", "HLT", "1997", "2001", "1", "1", "1", "1", "0", "", "", "1", "2", "2", "14.65", "17.58", "", "", "77.7", "67.6", "", "49.4", "", "2", "", "", "101", "1", "1", "80", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.4", "79.3", "", "", "", "", "79.3"]} -{"pcdb_id": 1987, "brand_name": "Potterton Myson", "model_name": "Kingfisher Mf RS 50", "model_qualifier": "", "winter_efficiency_pct": 77.6, "summer_efficiency_pct": 67.5, "comparative_hot_water_efficiency_pct": 49.3, "output_kw_max": 14.65, "final_year_of_manufacture": 2001, "raw": ["001987", "000005", "0", "2012/Mar/27 10:12", "Potterton Myson", "Potterton Myson", "Kingfisher Mf RS 50", "", "HLS", "1997", "2001", "1", "1", "1", "1", "0", "", "", "1", "2", "2", "11.72", "14.65", "", "", "77.6", "67.5", "", "49.3", "", "2", "", "", "101", "1", "1", "80", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "78.7", "79.6", "", "", "", "", "79.5"]} -{"pcdb_id": 1988, "brand_name": "Potterton Myson", "model_name": "Kingfisher Mf RS 40", "model_qualifier": "", "winter_efficiency_pct": 77.7, "summer_efficiency_pct": 67.6, "comparative_hot_water_efficiency_pct": 49.4, "output_kw_max": 11.72, "final_year_of_manufacture": 2002, "raw": ["001988", "000005", "0", "2012/Mar/27 10:12", "Potterton Myson", "Potterton Myson", "Kingfisher Mf RS 40", "", "HLR", "1997", "2002", "1", "1", "1", "1", "0", "", "", "1", "2", "2", "8.8", "11.72", "", "", "77.7", "67.6", "", "49.4", "", "2", "", "", "101", "1", "1", "80", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.0", "79.6", "", "", "", "", "79.5"]} -{"pcdb_id": 1989, "brand_name": "Potterton Myson", "model_name": "Kingfisher Mf CF 100", "model_qualifier": "", "winter_efficiency_pct": 77.8, "summer_efficiency_pct": 67.7, "comparative_hot_water_efficiency_pct": 49.5, "output_kw_max": 29.31, "final_year_of_manufacture": 2001, "raw": ["001989", "000005", "0", "2012/Mar/27 10:12", "Potterton Myson", "Potterton Myson", "Kingfisher Mf CF 100", "", "HME", "1997", "2001", "1", "1", "1", "1", "0", "", "", "1", "1", "2", "26.38", "29.31", "", "", "77.8", "67.7", "", "49.5", "", "2", "", "", "101", "1", "1", "80", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.2", "79.6", "", "", "", "", "79.6"]} -{"pcdb_id": 1990, "brand_name": "Potterton Myson", "model_name": "Kingfisher Mf CF 90", "model_qualifier": "", "winter_efficiency_pct": 78.5, "summer_efficiency_pct": 68.4, "comparative_hot_water_efficiency_pct": 49.9, "output_kw_max": 26.38, "final_year_of_manufacture": 2001, "raw": ["001990", "000005", "0", "2012/Mar/27 10:12", "Potterton Myson", "Potterton Myson", "Kingfisher Mf CF 90", "", "HMD", "1997", "2001", "1", "1", "1", "1", "0", "", "", "1", "1", "2", "23.45", "26.38", "", "", "78.5", "68.4", "", "49.9", "", "2", "", "", "101", "1", "1", "80", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.8", "80.3", "", "", "", "", "80.2"]} -{"pcdb_id": 1991, "brand_name": "Potterton Myson", "model_name": "Kingfisher Mf CF 80", "model_qualifier": "", "winter_efficiency_pct": 77.8, "summer_efficiency_pct": 67.7, "comparative_hot_water_efficiency_pct": 49.5, "output_kw_max": 23.45, "final_year_of_manufacture": 2001, "raw": ["001991", "000005", "0", "2012/Mar/27 10:12", "Potterton Myson", "Potterton Myson", "Kingfisher Mf CF 80", "", "HMC", "1997", "2001", "1", "1", "1", "1", "0", "", "", "1", "1", "2", "20.52", "23.45", "", "", "77.8", "67.7", "", "49.5", "", "2", "", "", "101", "1", "1", "80", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.4", "79.5", "", "", "", "", "79.5"]} -{"pcdb_id": 1992, "brand_name": "Potterton Myson", "model_name": "Kingfisher Mf CF 70", "model_qualifier": "", "winter_efficiency_pct": 77.4, "summer_efficiency_pct": 67.3, "comparative_hot_water_efficiency_pct": 49.2, "output_kw_max": 20.52, "final_year_of_manufacture": 2001, "raw": ["001992", "000005", "0", "2012/Mar/27 10:12", "Potterton Myson", "Potterton Myson", "Kingfisher Mf CF 70", "", "HMB", "1997", "2001", "1", "1", "1", "1", "0", "", "", "1", "1", "2", "17.58", "20.52", "", "", "77.4", "67.3", "", "49.2", "", "2", "", "", "101", "1", "1", "80", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "78.8", "79.2", "", "", "", "", "79.1"]} -{"pcdb_id": 1993, "brand_name": "Potterton Myson", "model_name": "Kingfisher Mf CF 60", "model_qualifier": "", "winter_efficiency_pct": 77.7, "summer_efficiency_pct": 67.6, "comparative_hot_water_efficiency_pct": 49.4, "output_kw_max": 17.58, "final_year_of_manufacture": 2001, "raw": ["001993", "000005", "0", "2012/Mar/27 10:12", "Potterton Myson", "Potterton Myson", "Kingfisher Mf CF 60", "", "HMA", "1997", "2001", "1", "1", "1", "1", "0", "", "", "1", "1", "2", "14.65", "17.58", "", "", "77.7", "67.6", "", "49.4", "", "2", "", "", "101", "1", "1", "80", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.4", "79.3", "", "", "", "", "79.3"]} -{"pcdb_id": 1994, "brand_name": "Potterton Myson", "model_name": "Kingfisher Mf CF 50", "model_qualifier": "", "winter_efficiency_pct": 77.6, "summer_efficiency_pct": 67.5, "comparative_hot_water_efficiency_pct": 49.3, "output_kw_max": 14.65, "final_year_of_manufacture": 2001, "raw": ["001994", "000005", "0", "2012/Mar/27 10:12", "Potterton Myson", "Potterton Myson", "Kingfisher Mf CF 50", "", "HLZ", "1997", "2001", "1", "1", "1", "1", "0", "", "", "1", "1", "2", "11.72", "14.65", "", "", "77.6", "67.5", "", "49.3", "", "2", "", "", "101", "1", "1", "80", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "78.7", "79.6", "", "", "", "", "79.5"]} -{"pcdb_id": 1995, "brand_name": "Potterton Myson", "model_name": "Kingfisher Mf CF 40", "model_qualifier": "", "winter_efficiency_pct": 77.7, "summer_efficiency_pct": 67.6, "comparative_hot_water_efficiency_pct": 49.4, "output_kw_max": 11.72, "final_year_of_manufacture": 2001, "raw": ["001995", "000005", "0", "2012/Mar/27 10:12", "Potterton Myson", "Potterton Myson", "Kingfisher Mf CF 40", "", "HLY", "1997", "2001", "1", "1", "1", "1", "0", "", "", "1", "1", "2", "8.8", "11.72", "", "", "77.7", "67.6", "", "49.4", "", "2", "", "", "101", "1", "1", "80", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.0", "79.6", "", "", "", "", "79.5"]} -{"pcdb_id": 1996, "brand_name": "Potterton Myson", "model_name": "Housewarmer 45", "model_qualifier": "", "winter_efficiency_pct": 78.3, "summer_efficiency_pct": 68.2, "comparative_hot_water_efficiency_pct": 49.8, "output_kw_max": 13.2, "final_year_of_manufacture": 2000, "raw": ["001996", "000005", "0", "2012/Mar/27 10:12", "Potterton Myson", "Potterton Myson", "Housewarmer 45", "", "HGK", "1994", "2000", "1", "4", "1", "1", "0", "", "", "1", "1", "1", "13.2", "13.2", "", "", "78.3", "68.2", "", "49.8", "", "2", "", "", "101", "1", "1", "5", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "77.9", "81.8", "", "", "", "", "81.1"]} -{"pcdb_id": 1997, "brand_name": "Potterton Myson", "model_name": "Housewarmer 55", "model_qualifier": "", "winter_efficiency_pct": 80.2, "summer_efficiency_pct": 70.1, "comparative_hot_water_efficiency_pct": 51.2, "output_kw_max": 16.1, "final_year_of_manufacture": 2000, "raw": ["001997", "000005", "0", "2012/Mar/27 10:12", "Potterton Myson", "Potterton Myson", "Housewarmer 55", "", "HGL", "1994", "2000", "1", "4", "1", "1", "0", "", "", "1", "1", "1", "16.1", "16.1", "", "", "80.2", "70.1", "", "51.2", "", "2", "", "", "101", "1", "1", "5", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.7", "83.9", "", "", "", "", "83.1"]} -{"pcdb_id": 2004, "brand_name": "Potterton Myson", "model_name": "Scottish Gas 30F2", "model_qualifier": "", "winter_efficiency_pct": 76.1, "summer_efficiency_pct": 66.0, "comparative_hot_water_efficiency_pct": 48.2, "output_kw_max": 8.79, "final_year_of_manufacture": 2001, "raw": ["002004", "000005", "0", "2012/Mar/27 10:12", "Potterton Myson", "Potterton Myson", "Scottish Gas 30F2", "", "LSB", "1999", "2001", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "5.86", "8.79", "", "", "76.1", "66.0", "", "48.2", "", "2", "", "", "101", "1", "1", "80", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "78.6", "76.8", "", "", "", "", "77.1"]} -{"pcdb_id": 2005, "brand_name": "Potterton Myson", "model_name": "Scottish Gas 40F2", "model_qualifier": "", "winter_efficiency_pct": 77.2, "summer_efficiency_pct": 67.1, "comparative_hot_water_efficiency_pct": 49.0, "output_kw_max": 11.72, "final_year_of_manufacture": 2001, "raw": ["002005", "000005", "0", "2012/Mar/27 10:12", "Potterton Myson", "Potterton Myson", "Scottish Gas 40F2", "", "LSC", "1999", "2001", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "8.79", "11.72", "", "", "77.2", "67.1", "", "49.0", "", "2", "", "", "101", "1", "1", "80", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.6", "78.0", "", "", "", "", "78.3"]} -{"pcdb_id": 2006, "brand_name": "Potterton Myson", "model_name": "Scottish Gas 50F2", "model_qualifier": "", "winter_efficiency_pct": 77.6, "summer_efficiency_pct": 67.5, "comparative_hot_water_efficiency_pct": 49.3, "output_kw_max": 14.65, "final_year_of_manufacture": 2001, "raw": ["002006", "000005", "0", "2012/Mar/27 10:12", "Potterton Myson", "Potterton Myson", "Scottish Gas 50F2", "", "LSD", "1999", "2001", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "11.72", "14.65", "", "", "77.6", "67.5", "", "49.3", "", "2", "", "", "101", "1", "1", "80", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "80.2", "78.3", "", "", "", "", "78.7"]} -{"pcdb_id": 2021, "brand_name": "Potterton Myson", "model_name": "Suprima 120", "model_qualifier": "", "winter_efficiency_pct": 78.7, "summer_efficiency_pct": 68.6, "comparative_hot_water_efficiency_pct": 50.1, "output_kw_max": 35.17, "final_year_of_manufacture": 2001, "raw": ["002021", "000005", "0", "2012/Mar/27 10:12", "Potterton Myson", "Potterton Myson", "Suprima 120", "", "HMT", "1999", "2001", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "23.45", "35.17", "", "", "78.7", "68.6", "", "50.1", "", "2", "", "", "101", "1", "1", "80", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "80.2", "80.4", "", "", "", "", "80.3"]} -{"pcdb_id": 2022, "brand_name": "Potterton Myson", "model_name": "Scottish Gas 80F2", "model_qualifier": "", "winter_efficiency_pct": 76.8, "summer_efficiency_pct": 66.7, "comparative_hot_water_efficiency_pct": 48.7, "output_kw_max": 23.45, "final_year_of_manufacture": 2001, "raw": ["002022", "000005", "0", "2012/Mar/27 10:12", "Potterton Myson", "Potterton Myson", "Scottish Gas 80F2", "", "LSF", "1999", "2001", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "17.58", "23.45", "", "", "76.8", "66.7", "", "48.7", "", "2", "", "", "101", "1", "1", "80", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.2", "77.6", "", "", "", "", "77.9"]} -{"pcdb_id": 2027, "brand_name": "Potterton Myson", "model_name": "Scottish Gas 60F2", "model_qualifier": "", "winter_efficiency_pct": 77.6, "summer_efficiency_pct": 67.5, "comparative_hot_water_efficiency_pct": 49.3, "output_kw_max": 17.58, "final_year_of_manufacture": 2001, "raw": ["002027", "000005", "0", "2012/Mar/27 10:12", "Potterton Myson", "Potterton Myson", "Scottish Gas 60F2", "", "LSE", "1999", "2001", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "14.65", "17.58", "", "", "77.6", "67.5", "", "49.3", "", "2", "", "", "101", "1", "1", "80", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "80.0", "78.4", "", "", "", "", "78.7"]} -{"pcdb_id": 2028, "brand_name": "Potterton Myson", "model_name": "Statesman Kitchen 90/110", "model_qualifier": "Kerosene", "winter_efficiency_pct": 83.0, "summer_efficiency_pct": 71.3, "comparative_hot_water_efficiency_pct": 52.1, "output_kw_max": 32.0, "final_year_of_manufacture": 2001, "raw": ["002028", "000005", "0", "2012/Mar/27 10:12", "Potterton Myson", "Potterton Myson", "Statesman Kitchen 90/110", "Kerosene", "LPX", "1998", "2001", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "26.0", "32.0", "", "", "83.0", "71.3", "", "52.1", "", "2", "", "", "201", "1", "1", "200", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "83.6", "82.5", "", "", "", "", "82.7"]} -{"pcdb_id": 2029, "brand_name": "Potterton Myson", "model_name": "Statesman Kitchen 90/110", "model_qualifier": "Gas oil", "winter_efficiency_pct": 83.0, "summer_efficiency_pct": 71.3, "comparative_hot_water_efficiency_pct": 52.1, "output_kw_max": 32.0, "final_year_of_manufacture": 2001, "raw": ["002029", "000005", "0", "2012/Mar/27 10:12", "Potterton Myson", "Potterton Myson", "Statesman Kitchen 90/110", "Gas oil", "LPT", "1998", "2001", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "26.0", "32.0", "", "", "83.0", "71.3", "", "52.1", "", "2", "", "", "201", "1", "1", "200", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "83.6", "82.5", "", "", "", "", "82.7"]} -{"pcdb_id": 2030, "brand_name": "Potterton Myson", "model_name": "Statesman Utility 50/70", "model_qualifier": "Kerosene", "winter_efficiency_pct": 82.5, "summer_efficiency_pct": 70.8, "comparative_hot_water_efficiency_pct": 51.7, "output_kw_max": 20.0, "final_year_of_manufacture": 2001, "raw": ["002030", "000005", "0", "2012/Mar/27 10:12", "Potterton Myson", "Potterton Myson", "Statesman Utility 50/70", "Kerosene", "LRH", "1998", "2001", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "15.0", "20.0", "", "", "82.5", "70.8", "", "51.7", "", "2", "", "", "201", "1", "1", "200", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.6", "83.3", "", "", "", "", "83.0"]} -{"pcdb_id": 2031, "brand_name": "Potterton Myson", "model_name": "Statesman Kitchen 45/50", "model_qualifier": "Kerosene", "winter_efficiency_pct": 86.2, "summer_efficiency_pct": 74.5, "comparative_hot_water_efficiency_pct": 54.4, "output_kw_max": 15.0, "final_year_of_manufacture": 2001, "raw": ["002031", "000005", "0", "2012/Mar/27 10:12", "Potterton Myson", "Potterton Myson", "Statesman Kitchen 45/50", "Kerosene", "LRB", "1998", "2001", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "13.0", "15.0", "", "", "86.2", "74.5", "", "54.4", "", "2", "", "", "201", "1", "1", "200", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.3", "86.1", "", "", "", "", "86.3"]} -{"pcdb_id": 2032, "brand_name": "Potterton Myson", "model_name": "Statesman Utility 50/70", "model_qualifier": "Gas oil", "winter_efficiency_pct": 82.5, "summer_efficiency_pct": 70.8, "comparative_hot_water_efficiency_pct": 51.7, "output_kw_max": 20.0, "final_year_of_manufacture": 2001, "raw": ["002032", "000005", "0", "2012/Mar/27 10:12", "Potterton Myson", "Potterton Myson", "Statesman Utility 50/70", "Gas oil", "LRE", "1998", "2001", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "15.0", "20.0", "", "", "82.5", "70.8", "", "51.7", "", "2", "", "", "201", "1", "1", "200", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.6", "83.3", "", "", "", "", "83.0"]} -{"pcdb_id": 2033, "brand_name": "Potterton Myson", "model_name": "Statesman Utility 70/90", "model_qualifier": "Gas oil", "winter_efficiency_pct": 85.9, "summer_efficiency_pct": 74.2, "comparative_hot_water_efficiency_pct": 54.2, "output_kw_max": 26.0, "final_year_of_manufacture": 2001, "raw": ["002033", "000005", "0", "2012/Mar/27 10:12", "Potterton Myson", "Potterton Myson", "Statesman Utility 70/90", "Gas oil", "LRD", "1998", "2001", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "20.0", "26.0", "", "", "85.9", "74.2", "", "54.2", "", "2", "", "", "201", "1", "1", "200", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.3", "85.5", "", "", "", "", "85.9"]} -{"pcdb_id": 2034, "brand_name": "Potterton Myson", "model_name": "Statesman Utility 70/90", "model_qualifier": "Kerosene", "winter_efficiency_pct": 85.9, "summer_efficiency_pct": 74.2, "comparative_hot_water_efficiency_pct": 54.2, "output_kw_max": 26.0, "final_year_of_manufacture": 2001, "raw": ["002034", "000005", "0", "2012/Mar/27 10:12", "Potterton Myson", "Potterton Myson", "Statesman Utility 70/90", "Kerosene", "LRG", "1998", "2001", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "20.0", "26.0", "", "", "85.9", "74.2", "", "54.2", "", "2", "", "", "201", "1", "1", "200", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.3", "85.5", "", "", "", "", "85.9"]} -{"pcdb_id": 2035, "brand_name": "Potterton Myson", "model_name": "Statesman Flowsure plus", "model_qualifier": "", "winter_efficiency_pct": 79.2, "summer_efficiency_pct": 71.1, "comparative_hot_water_efficiency_pct": 31.9, "output_kw_max": 25.0, "final_year_of_manufacture": 2001, "raw": ["002035", "000005", "0", "2024/Jan/31 10:17", "Potterton Myson", "Potterton Myson", "Statesman Flowsure plus", "", "LNC", "1996", "2001", "4", "1", "1", "2", "0", "", "", "1", "1", "2", "19", "25.0", "", "", "79.2", "71.1", "", "31.9", "", "2", "", "", "203", "1", "1", "200", "0", "1", "1", "0", "40", "0", "13", "4", "73", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.0", "80.2", "", "", "", "", "80.5"]} -{"pcdb_id": 2036, "brand_name": "Potterton Myson", "model_name": "Statesman Flowsure", "model_qualifier": "", "winter_efficiency_pct": 79.3, "summer_efficiency_pct": 69.8, "comparative_hot_water_efficiency_pct": 49.1, "output_kw_max": 25.0, "final_year_of_manufacture": 2001, "raw": ["002036", "000005", "0", "2005/Nov/15 11:32", "Potterton Myson", "Potterton Myson", "Statesman Flowsure", "", "LNB", "1996", "2001", "4", "1", "1", "2", "0", "", "", "1", "1", "2", "19.0", "25.0", "", "", "79.3", "69.8", "", "49.1", "", "2", "", "", "202", "1", "1", "200", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.0", "80.2", "", "", "", "", "80.5"]} -{"pcdb_id": 2037, "brand_name": "Potterton Myson", "model_name": "Statesman System 65/85", "model_qualifier": "", "winter_efficiency_pct": 81.1, "summer_efficiency_pct": 69.4, "comparative_hot_water_efficiency_pct": 50.7, "output_kw_max": 25.0, "final_year_of_manufacture": 2001, "raw": ["002037", "000005", "0", "2012/Mar/27 10:12", "Potterton Myson", "Potterton Myson", "Statesman System 65/85", "", "LNA", "1996", "2001", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "19.0", "25.0", "", "", "81.1", "69.4", "", "50.7", "", "2", "", "", "201", "1", "1", "200", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.0", "80.2", "", "", "", "", "80.5"]} -{"pcdb_id": 2038, "brand_name": "Potterton Myson", "model_name": "Suprima 30", "model_qualifier": "", "winter_efficiency_pct": 77.5, "summer_efficiency_pct": 67.4, "comparative_hot_water_efficiency_pct": 49.2, "output_kw_max": 8.8, "final_year_of_manufacture": 2001, "raw": ["002038", "000005", "0", "2012/Mar/27 10:12", "Potterton Myson", "Potterton Myson", "Suprima 30", "", "HHN", "1997", "2001", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "5.5", "8.8", "", "", "77.5", "67.4", "", "49.2", "", "2", "", "", "101", "1", "1", "80", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.6", "78.6", "", "", "", "", "78.8"]} -{"pcdb_id": 2039, "brand_name": "Potterton Myson", "model_name": "Suprima 40", "model_qualifier": "", "winter_efficiency_pct": 77.7, "summer_efficiency_pct": 67.6, "comparative_hot_water_efficiency_pct": 49.4, "output_kw_max": 11.7, "final_year_of_manufacture": 2001, "raw": ["002039", "000005", "0", "2012/Mar/27 10:12", "Potterton Myson", "Potterton Myson", "Suprima 40", "", "HHO", "1997", "2001", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "8.5", "11.7", "", "", "77.7", "67.6", "", "49.4", "", "2", "", "", "101", "1", "1", "80", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "80.1", "78.6", "", "", "", "", "78.9"]} -{"pcdb_id": 2040, "brand_name": "Potterton Myson", "model_name": "Suprima 50", "model_qualifier": "", "winter_efficiency_pct": 78.4, "summer_efficiency_pct": 68.3, "comparative_hot_water_efficiency_pct": 49.9, "output_kw_max": 14.7, "final_year_of_manufacture": 2001, "raw": ["002040", "000005", "0", "2012/Mar/27 10:12", "Potterton Myson", "Potterton Myson", "Suprima 50", "", "HHP", "1997", "2001", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "11.4", "14.7", "", "", "78.4", "68.3", "", "49.9", "", "2", "", "", "101", "1", "1", "80", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "80.5", "79.5", "", "", "", "", "79.7"]} -{"pcdb_id": 2041, "brand_name": "Potterton Myson", "model_name": "Suprima 60", "model_qualifier": "", "winter_efficiency_pct": 78.8, "summer_efficiency_pct": 68.7, "comparative_hot_water_efficiency_pct": 50.2, "output_kw_max": 17.6, "final_year_of_manufacture": 2001, "raw": ["002041", "000005", "0", "2012/Mar/27 10:12", "Potterton Myson", "Potterton Myson", "Suprima 60", "", "HHR", "1997", "2001", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "14.4", "17.6", "", "", "78.8", "68.7", "", "50.2", "", "2", "", "", "101", "1", "1", "80", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "80.9", "79.8", "", "", "", "", "80.0"]} -{"pcdb_id": 2042, "brand_name": "Potterton Myson", "model_name": "Suprima 70", "model_qualifier": "", "winter_efficiency_pct": 79.3, "summer_efficiency_pct": 69.2, "comparative_hot_water_efficiency_pct": 50.6, "output_kw_max": 20.5, "final_year_of_manufacture": 2001, "raw": ["002042", "000005", "0", "2012/Mar/27 10:12", "Potterton Myson", "Potterton Myson", "Suprima 70", "", "HHS", "1997", "2001", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "17.3", "20.5", "", "", "79.3", "69.2", "", "50.6", "", "2", "", "", "101", "1", "1", "80", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.3", "80.5", "", "", "", "", "80.7"]} -{"pcdb_id": 2043, "brand_name": "Potterton Myson", "model_name": "Suprima 80", "model_qualifier": "", "winter_efficiency_pct": 78.1, "summer_efficiency_pct": 68.0, "comparative_hot_water_efficiency_pct": 49.7, "output_kw_max": 23.4, "final_year_of_manufacture": 2001, "raw": ["002043", "000005", "0", "2012/Mar/27 10:12", "Potterton Myson", "Potterton Myson", "Suprima 80", "", "HHT", "1997", "2001", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "20.1", "23.4", "", "", "78.1", "68.0", "", "49.7", "", "2", "", "", "101", "1", "1", "80", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "80.4", "79.1", "", "", "", "", "79.3"]} -{"pcdb_id": 2044, "brand_name": "Potterton Myson", "model_name": "Suprima 100", "model_qualifier": "", "winter_efficiency_pct": 79.2, "summer_efficiency_pct": 69.1, "comparative_hot_water_efficiency_pct": 50.5, "output_kw_max": 28.72, "final_year_of_manufacture": 2001, "raw": ["002044", "000005", "0", "2012/Mar/27 10:12", "Potterton Myson", "Potterton Myson", "Suprima 100", "", "HHV", "1997", "2001", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "28.72", "28.72", "", "", "79.2", "69.1", "", "50.5", "", "2", "", "", "101", "1", "1", "80", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.1", "80.5", "", "", "", "", "80.7"]} -{"pcdb_id": 2045, "brand_name": "Potterton Myson", "model_name": "Puma Flowsure plus", "model_qualifier": "", "winter_efficiency_pct": 80.4, "summer_efficiency_pct": 71.3, "comparative_hot_water_efficiency_pct": 41.3, "output_kw_max": 24.0, "final_year_of_manufacture": 2000, "raw": ["002045", "000005", "0", "2024/Jan/31 10:17", "Potterton Myson", "Potterton Myson", "Puma Flowsure plus", "", "LKX + LLN", "1996", "2000", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "24.0", "24.0", "", "", "80.4", "71.3", "", "41.3", "", "2", "", "", "106", "1", "2", "90", "0", "2", "1", "0", "44.7", "0", "20", "5", "73", "37", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.3", "81.3", "", "", "", "", "81.3"]} -{"pcdb_id": 2046, "brand_name": "Potterton Myson", "model_name": "Puma 80e Security", "model_qualifier": "", "winter_efficiency_pct": 80.1, "summer_efficiency_pct": 70.0, "comparative_hot_water_efficiency_pct": 49.2, "output_kw_max": 24.0, "final_year_of_manufacture": 2001, "raw": ["002046", "000005", "0", "2006/Jan/17 12:55", "Potterton Myson", "Potterton Myson", "Puma 80e Security", "", "LSG", "1999", "2001", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "24.0", "24.0", "", "", "80.1", "70.0", "", "49.2", "", "2", "", "", "104", "1", "2", "90", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.3", "81.3", "", "", "", "", "81.3"]} -{"pcdb_id": 2047, "brand_name": "Potterton Myson", "model_name": "Puma 80e", "model_qualifier": "", "winter_efficiency_pct": 80.1, "summer_efficiency_pct": 70.0, "comparative_hot_water_efficiency_pct": 49.2, "output_kw_max": 24.0, "final_year_of_manufacture": 2001, "raw": ["002047", "000005", "0", "2006/Jan/17 12:55", "Potterton Myson", "Potterton Myson", "Puma 80e", "", "LGD", "1993", "2001", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "24.0", "24.0", "", "", "80.1", "70.0", "", "49.2", "", "2", "", "", "104", "1", "2", "90", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.3", "81.3", "", "", "", "", "81.3"]} -{"pcdb_id": 2048, "brand_name": "Potterton Myson", "model_name": "Puma 80 Security", "model_qualifier": "", "winter_efficiency_pct": 76.1, "summer_efficiency_pct": 66.0, "comparative_hot_water_efficiency_pct": 46.4, "output_kw_max": 24.0, "final_year_of_manufacture": 2001, "raw": ["002048", "000005", "0", "2006/Jan/17 12:55", "Potterton Myson", "Potterton Myson", "Puma 80 Security", "", "LSH", "1999", "2001", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "24.0", "24.0", "", "", "76.1", "66.0", "", "46.4", "", "2", "", "", "104", "2", "2", "90", "20", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.3", "81.3", "", "", "", "", "81.3"]} -{"pcdb_id": 2049, "brand_name": "Potterton Myson", "model_name": "Puma 80", "model_qualifier": "", "winter_efficiency_pct": 76.1, "summer_efficiency_pct": 66.0, "comparative_hot_water_efficiency_pct": 46.4, "output_kw_max": 24.0, "final_year_of_manufacture": 2001, "raw": ["002049", "000005", "0", "2006/Jan/17 12:55", "Potterton Myson", "Potterton Myson", "Puma 80", "", "LGC", "1993", "2001", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "24.0", "24.0", "", "", "76.1", "66.0", "", "46.4", "", "2", "", "", "104", "2", "2", "90", "20", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.3", "81.3", "", "", "", "", "81.3"]} -{"pcdb_id": 2050, "brand_name": "Potterton Myson", "model_name": "Puma 100 Security", "model_qualifier": "", "winter_efficiency_pct": 75.7, "summer_efficiency_pct": 65.6, "comparative_hot_water_efficiency_pct": 46.1, "output_kw_max": 29.0, "final_year_of_manufacture": 2001, "raw": ["002050", "000005", "0", "2006/Jan/17 12:55", "Potterton Myson", "Potterton Myson", "Puma 100 Security", "", "LSK", "1999", "2001", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "29.0", "29.0", "", "", "75.7", "65.6", "", "46.1", "", "2", "", "", "104", "2", "2", "90", "20", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.2", "80.5", "", "", "", "", "80.7"]} -{"pcdb_id": 2051, "brand_name": "Potterton Myson", "model_name": "Puma 100e Security", "model_qualifier": "", "winter_efficiency_pct": 79.7, "summer_efficiency_pct": 69.6, "comparative_hot_water_efficiency_pct": 48.9, "output_kw_max": 29.0, "final_year_of_manufacture": 2001, "raw": ["002051", "000005", "0", "2006/Jan/17 12:55", "Potterton Myson", "Potterton Myson", "Puma 100e Security", "", "LSJ", "1999", "2001", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "29.0", "29.0", "", "", "79.7", "69.6", "", "48.9", "", "2", "", "", "104", "1", "2", "90", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.2", "80.5", "", "", "", "", "80.7"]} -{"pcdb_id": 2052, "brand_name": "Potterton Myson", "model_name": "Puma 100ec", "model_qualifier": "", "winter_efficiency_pct": 79.7, "summer_efficiency_pct": 69.6, "comparative_hot_water_efficiency_pct": 48.9, "output_kw_max": 29.0, "final_year_of_manufacture": 2001, "raw": ["002052", "000005", "0", "2006/Jan/17 12:55", "Potterton Myson", "Potterton Myson", "Puma 100ec", "", "LRS", "1999", "2001", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "29.0", "29.0", "", "", "79.7", "69.6", "", "48.9", "", "2", "", "", "104", "1", "2", "90", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.2", "80.5", "", "", "", "", "80.7"]} -{"pcdb_id": 2053, "brand_name": "Potterton Myson", "model_name": "Puma 100e", "model_qualifier": "", "winter_efficiency_pct": 79.7, "summer_efficiency_pct": 69.6, "comparative_hot_water_efficiency_pct": 48.9, "output_kw_max": 29.0, "final_year_of_manufacture": 2001, "raw": ["002053", "000005", "0", "2006/Jan/17 12:55", "Potterton Myson", "Potterton Myson", "Puma 100e", "", "LGF", "1993", "2001", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "29.0", "29.0", "", "", "79.7", "69.6", "", "48.9", "", "2", "", "", "104", "1", "2", "90", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.2", "80.5", "", "", "", "", "80.7"]} -{"pcdb_id": 2054, "brand_name": "Potterton Myson", "model_name": "Puma 100", "model_qualifier": "", "winter_efficiency_pct": 75.7, "summer_efficiency_pct": 65.6, "comparative_hot_water_efficiency_pct": 46.1, "output_kw_max": 29.0, "final_year_of_manufacture": 2001, "raw": ["002054", "000005", "0", "2006/Jan/17 12:55", "Potterton Myson", "Potterton Myson", "Puma 100", "", "LGE", "1993", "2001", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "29.0", "29.0", "", "", "75.7", "65.6", "", "46.1", "", "2", "", "", "104", "2", "2", "90", "20", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.2", "80.5", "", "", "", "", "80.7"]} -{"pcdb_id": 2055, "brand_name": "Potterton Myson", "model_name": "Combi 80", "model_qualifier": "", "winter_efficiency_pct": 80.1, "summer_efficiency_pct": 70.0, "comparative_hot_water_efficiency_pct": 49.2, "output_kw_max": 24.0, "final_year_of_manufacture": 2001, "raw": ["002055", "000005", "0", "2006/Jan/17 12:55", "Potterton Myson", "Potterton Myson", "Combi 80", "", "LRK", "1998", "2001", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "24.0", "24.0", "", "", "80.1", "70.0", "", "49.2", "", "2", "", "", "104", "1", "2", "200", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.3", "81.3", "", "", "", "", "81.3"]} -{"pcdb_id": 2056, "brand_name": "Potterton Myson", "model_name": "Statesman Kitchen 50/70", "model_qualifier": "Gas oil", "winter_efficiency_pct": 82.5, "summer_efficiency_pct": 70.8, "comparative_hot_water_efficiency_pct": 51.7, "output_kw_max": 20.0, "final_year_of_manufacture": 2001, "raw": ["002056", "000005", "0", "2012/Mar/27 10:12", "Potterton Myson", "Potterton Myson", "Statesman Kitchen 50/70", "Gas oil", "LPW", "1998", "2001", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "15.0", "20.0", "", "", "82.5", "70.8", "", "51.7", "", "2", "", "", "201", "1", "1", "200", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.6", "83.3", "", "", "", "", "83.0"]} -{"pcdb_id": 2057, "brand_name": "Potterton Myson", "model_name": "Statesman Kitchen 50/70", "model_qualifier": "Kerosene", "winter_efficiency_pct": 82.5, "summer_efficiency_pct": 70.8, "comparative_hot_water_efficiency_pct": 51.7, "output_kw_max": 20.0, "final_year_of_manufacture": 2001, "raw": ["002057", "000005", "0", "2012/Mar/27 10:12", "Potterton Myson", "Potterton Myson", "Statesman Kitchen 50/70", "Kerosene", "LRA", "1998", "2001", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "15.0", "20.0", "", "", "82.5", "70.8", "", "51.7", "", "2", "", "", "201", "1", "1", "200", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.6", "83.3", "", "", "", "", "83.0"]} -{"pcdb_id": 2058, "brand_name": "Potterton Myson", "model_name": "Statesman Kitchen 70/90", "model_qualifier": "Gas oil", "winter_efficiency_pct": 85.9, "summer_efficiency_pct": 74.2, "comparative_hot_water_efficiency_pct": 54.2, "output_kw_max": 26.0, "final_year_of_manufacture": 2001, "raw": ["002058", "000005", "0", "2012/Mar/27 10:12", "Potterton Myson", "Potterton Myson", "Statesman Kitchen 70/90", "Gas oil", "LPV", "1998", "2001", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "20.0", "26.0", "", "", "85.9", "74.2", "", "54.2", "", "2", "", "", "201", "1", "1", "200", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.3", "85.5", "", "", "", "", "85.9"]} -{"pcdb_id": 2059, "brand_name": "Potterton Myson", "model_name": "Statesman Utility 90/110", "model_qualifier": "Gas oil", "winter_efficiency_pct": 83.0, "summer_efficiency_pct": 71.3, "comparative_hot_water_efficiency_pct": 52.1, "output_kw_max": 32.0, "final_year_of_manufacture": 2001, "raw": ["002059", "000005", "0", "2012/Mar/27 10:12", "Potterton Myson", "Potterton Myson", "Statesman Utility 90/110", "Gas oil", "LRC", "1998", "2001", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "26.0", "32.0", "", "", "83.0", "71.3", "", "52.1", "", "2", "", "", "201", "1", "1", "200", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "83.6", "82.5", "", "", "", "", "82.7"]} -{"pcdb_id": 2060, "brand_name": "Potterton Myson", "model_name": "Statesman Kitchen 70/90", "model_qualifier": "Kerosene", "winter_efficiency_pct": 85.9, "summer_efficiency_pct": 74.2, "comparative_hot_water_efficiency_pct": 54.2, "output_kw_max": 26.0, "final_year_of_manufacture": 2001, "raw": ["002060", "000005", "0", "2012/Mar/27 10:12", "Potterton Myson", "Potterton Myson", "Statesman Kitchen 70/90", "Kerosene", "LPY", "1998", "2001", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "20.0", "26.0", "", "", "85.9", "74.2", "", "54.2", "", "2", "", "", "201", "1", "1", "200", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.3", "85.5", "", "", "", "", "85.9"]} -{"pcdb_id": 2061, "brand_name": "Potterton Myson", "model_name": "Statesman Utility 90/110", "model_qualifier": "Kerosene", "winter_efficiency_pct": 83.0, "summer_efficiency_pct": 71.3, "comparative_hot_water_efficiency_pct": 52.1, "output_kw_max": 32.0, "final_year_of_manufacture": 2001, "raw": ["002061", "000005", "0", "2012/Mar/27 10:12", "Potterton Myson", "Potterton Myson", "Statesman Utility 90/110", "Kerosene", "LRF", "1998", "2001", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "26.0", "32.0", "", "", "83.0", "71.3", "", "52.1", "", "2", "", "", "201", "1", "1", "200", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "83.6", "82.5", "", "", "", "", "82.7"]} -{"pcdb_id": 2062, "brand_name": "Potterton Myson", "model_name": "Envoy 30 System", "model_qualifier": "", "winter_efficiency_pct": 85.6, "summer_efficiency_pct": 78.0, "comparative_hot_water_efficiency_pct": 57.0, "output_kw_max": 9.7, "final_year_of_manufacture": 2000, "raw": ["002062", "000005", "0", "2012/Mar/27 10:12", "Potterton Myson", "Potterton Myson", "Envoy 30 System", "", "HKK", "1995", "2000", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "9.7", "9.7", "", "", "85.6", "78.0", "", "57.0", "", "2", "", "", "101", "1", "1", "80", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "87.5", "94.5", "", "", "", "", "93.2"]} -{"pcdb_id": 2063, "brand_name": "Potterton Myson", "model_name": "Envoy 40 System", "model_qualifier": "", "winter_efficiency_pct": 85.5, "summer_efficiency_pct": 77.9, "comparative_hot_water_efficiency_pct": 56.9, "output_kw_max": 12.8, "final_year_of_manufacture": 2000, "raw": ["002063", "000005", "0", "2012/Mar/27 10:12", "Potterton Myson", "Potterton Myson", "Envoy 40 System", "", "HKL", "1995", "2000", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "12.8", "12.8", "", "", "85.5", "77.9", "", "56.9", "", "2", "", "", "101", "1", "1", "80", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "87.8", "94.0", "", "", "", "", "92.8"]} -{"pcdb_id": 2064, "brand_name": "Potterton Myson", "model_name": "Envoy 50 System", "model_qualifier": "", "winter_efficiency_pct": 85.5, "summer_efficiency_pct": 77.9, "comparative_hot_water_efficiency_pct": 56.9, "output_kw_max": 16.1, "final_year_of_manufacture": 2000, "raw": ["002064", "000005", "0", "2012/Mar/27 10:12", "Potterton Myson", "Potterton Myson", "Envoy 50 System", "", "HKM", "1995", "2000", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "16.1", "16.1", "", "", "85.5", "77.9", "", "56.9", "", "2", "", "", "101", "1", "1", "80", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "88.0", "94.0", "", "", "", "", "92.8"]} -{"pcdb_id": 2065, "brand_name": "Potterton Myson", "model_name": "Envoy 60 System", "model_qualifier": "", "winter_efficiency_pct": 85.2, "summer_efficiency_pct": 77.6, "comparative_hot_water_efficiency_pct": 56.7, "output_kw_max": 19.0, "final_year_of_manufacture": 2000, "raw": ["002065", "000005", "0", "2012/Mar/27 10:12", "Potterton Myson", "Potterton Myson", "Envoy 60 System", "", "HKN", "1995", "2000", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "19.0", "19.0", "", "", "85.2", "77.6", "", "56.7", "", "2", "", "", "101", "1", "1", "80", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "86.8", "93.8", "", "", "", "", "92.5"]} -{"pcdb_id": 2066, "brand_name": "Potterton Myson", "model_name": "Envoy 80 System", "model_qualifier": "", "winter_efficiency_pct": 85.1, "summer_efficiency_pct": 77.5, "comparative_hot_water_efficiency_pct": 56.6, "output_kw_max": 25.0, "final_year_of_manufacture": 2000, "raw": ["002066", "000005", "0", "2012/Mar/27 10:12", "Potterton Myson", "Potterton Myson", "Envoy 80 System", "", "HKP", "1995", "2000", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "25", "25.0", "", "", "85.1", "77.5", "", "56.6", "", "2", "", "", "101", "1", "1", "80", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "87.4", "93.3", "", "", "", "", "92.2"]} -{"pcdb_id": 2067, "brand_name": "Potterton Myson", "model_name": "Envoy 80 Flowsure", "model_qualifier": "", "winter_efficiency_pct": 86.5, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 49.0, "output_kw_max": 25.0, "final_year_of_manufacture": 2000, "raw": ["002067", "000005", "0", "2024/Jan/31 10:17", "Potterton Myson", "Potterton Myson", "Envoy 80 Flowsure", "", "HKW", "1996", "2000", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "25.0", "25.0", "", "", "86.5", "79.2", "", "49.0", "", "2", "", "", "106", "1", "2", "80", "0", "1", "1", "0", "18.7", "0", "35", "2", "75", "20", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.4", "93.3", "", "", "", "", "92.2"]} -{"pcdb_id": 2068, "brand_name": "Potterton Myson", "model_name": "Envoy 80 Flowsure plus", "model_qualifier": "", "winter_efficiency_pct": 86.5, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 45.9, "output_kw_max": 25.0, "final_year_of_manufacture": 2000, "raw": ["002068", "000005", "0", "2024/Jan/31 10:17", "Potterton Myson", "Potterton Myson", "Envoy 80 Flowsure plus", "", "HKW", "1996", "2000", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "25.0", "25.0", "", "", "86.5", "79.2", "", "45.9", "", "2", "", "", "106", "1", "2", "80", "0", "2", "1", "0", "44.7", "0", "20", "5", "73", "37", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.4", "93.3", "", "", "", "", "92.2"]} -{"pcdb_id": 3971, "brand_name": "Keston", "model_name": "Thermomatic", "model_qualifier": "RSM20FB", "winter_efficiency_pct": 78.9, "summer_efficiency_pct": 69.6, "comparative_hot_water_efficiency_pct": 48.9, "output_kw_max": 23.0, "final_year_of_manufacture": null, "raw": ["003971", "000022", "0", "2001/Nov/30 13:26", "Thermomatic Srl", "Keston", "Thermomatic", "RSM20FB", "", "1988", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "23", "23", "", "", "78.9", "69.6", "", "48.9", "", "2", "", "", "103", "1", "1", "180", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.5", "80.3", "", "", "", "", "80.5"]} -{"pcdb_id": 3972, "brand_name": "Keston", "model_name": "Thermomatic", "model_qualifier": "RSM25FB", "winter_efficiency_pct": 78.8, "summer_efficiency_pct": 69.5, "comparative_hot_water_efficiency_pct": 48.9, "output_kw_max": 28.0, "final_year_of_manufacture": null, "raw": ["003972", "000022", "0", "2001/Nov/30 13:26", "Thermomatic Srl", "Keston", "Thermomatic", "RSM25FB", "", "1988", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "28", "28", "", "", "78.8", "69.5", "", "48.9", "", "2", "", "", "103", "1", "1", "180", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.4", "80.3", "", "", "", "", "80.5"]} -{"pcdb_id": 3975, "brand_name": "Glow-worm", "model_name": "Energysaver 80", "model_qualifier": "", "winter_efficiency_pct": 85.0, "summer_efficiency_pct": 77.4, "comparative_hot_water_efficiency_pct": 56.5, "output_kw_max": 23.4, "final_year_of_manufacture": 2003, "raw": ["003975", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Energysaver 80", "", "41 319 84", "1994", "2003", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "20.5", "23.4", "", "", "85.0", "77.4", "", "56.5", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "88.0", "92.7", "", "", "", "", "91.8"]} -{"pcdb_id": 3976, "brand_name": "Glow-worm", "model_name": "Energysaver 80P", "model_qualifier": "", "winter_efficiency_pct": 86.0, "summer_efficiency_pct": 78.4, "comparative_hot_water_efficiency_pct": 57.2, "output_kw_max": 23.4, "final_year_of_manufacture": 2003, "raw": ["003976", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Energysaver 80P", "", "41 319 85", "1994", "2003", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "17.6", "23.4", "", "", "86.0", "78.4", "", "57.2", "", "2", "0", "", "101", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "88.1", "92.9", "", "", "", "", "92.0"]} -{"pcdb_id": 3977, "brand_name": "Glow-worm", "model_name": "Energysaver 70", "model_qualifier": "", "winter_efficiency_pct": 85.0, "summer_efficiency_pct": 77.4, "comparative_hot_water_efficiency_pct": 56.5, "output_kw_max": 20.5, "final_year_of_manufacture": 2002, "raw": ["003977", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Energysaver 70", "", "41 319 92", "1994", "2002", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "17.6", "20.5", "", "", "85.0", "77.4", "", "56.5", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "88.0", "92.7", "", "", "", "", "91.8"]} -{"pcdb_id": 3978, "brand_name": "Glow-worm", "model_name": "Energysaver 50e", "model_qualifier": "", "winter_efficiency_pct": 84.5, "summer_efficiency_pct": 76.9, "comparative_hot_water_efficiency_pct": 56.2, "output_kw_max": 14.65, "final_year_of_manufacture": 2002, "raw": ["003978", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Energysaver 50e", "", "41 319 94", "1996", "2002", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "14.65", "14.65", "", "", "84.5", "76.9", "", "56.2", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "86.6", "92.1", "", "", "", "", "91.0"]} -{"pcdb_id": 3979, "brand_name": "Glow-worm", "model_name": "Energysaver 60e", "model_qualifier": "", "winter_efficiency_pct": 84.6, "summer_efficiency_pct": 77.0, "comparative_hot_water_efficiency_pct": 56.2, "output_kw_max": 17.58, "final_year_of_manufacture": 2002, "raw": ["003979", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Energysaver 60e", "", "41 319 95", "1996", "2002", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "17.58", "17.58", "", "", "84.6", "77.0", "", "56.2", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "86.6", "92.2", "", "", "", "", "91.1"]} -{"pcdb_id": 3980, "brand_name": "Glow-worm", "model_name": "Energysaver 40", "model_qualifier": "", "winter_efficiency_pct": 84.4, "summer_efficiency_pct": 76.8, "comparative_hot_water_efficiency_pct": 56.1, "output_kw_max": 11.72, "final_year_of_manufacture": 2003, "raw": ["003980", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Energysaver 40", "", "41 319 69", "1993", "2003", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "8.79", "11.72", "", "", "84.4", "76.8", "", "56.1", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "86.6", "91.9", "", "", "", "", "90.9"]} -{"pcdb_id": 3981, "brand_name": "Glow-worm", "model_name": "Energysaver 50", "model_qualifier": "", "winter_efficiency_pct": 84.5, "summer_efficiency_pct": 76.9, "comparative_hot_water_efficiency_pct": 56.2, "output_kw_max": 14.65, "final_year_of_manufacture": 2002, "raw": ["003981", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Energysaver 50", "", "41 319 70", "1993", "2002", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "11.72", "14.65", "", "", "84.5", "76.9", "", "56.2", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "86.6", "92.1", "", "", "", "", "91.0"]} -{"pcdb_id": 3982, "brand_name": "Glow-worm", "model_name": "Energysaver 60", "model_qualifier": "", "winter_efficiency_pct": 84.6, "summer_efficiency_pct": 77.0, "comparative_hot_water_efficiency_pct": 56.2, "output_kw_max": 17.58, "final_year_of_manufacture": 2003, "raw": ["003982", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Energysaver 60", "", "41 319 71", "1993", "2003", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "14.65", "17.58", "", "", "84.6", "77.0", "", "56.2", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "86.6", "92.2", "", "", "", "", "91.1"]} -{"pcdb_id": 3983, "brand_name": "Glow-worm", "model_name": "Energysaver 40P", "model_qualifier": "", "winter_efficiency_pct": 84.8, "summer_efficiency_pct": 77.2, "comparative_hot_water_efficiency_pct": 56.4, "output_kw_max": 11.72, "final_year_of_manufacture": 2003, "raw": ["003983", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Energysaver 40P", "", "41 319 72", "1993", "2003", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "8.79", "11.72", "", "", "84.8", "77.2", "", "56.4", "", "2", "0", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "86.6", "91.8", "", "", "", "", "90.8"]} -{"pcdb_id": 3984, "brand_name": "Glow-worm", "model_name": "Energysaver 50P", "model_qualifier": "", "winter_efficiency_pct": 84.9, "summer_efficiency_pct": 77.3, "comparative_hot_water_efficiency_pct": 56.4, "output_kw_max": 14.65, "final_year_of_manufacture": 2002, "raw": ["003984", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Energysaver 50P", "", "41 319 73", "1993", "2002", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "11.72", "14.65", "", "", "84.9", "77.3", "", "56.4", "", "2", "0", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "86.6", "92.0", "", "", "", "", "91.0"]} -{"pcdb_id": 3985, "brand_name": "Glow-worm", "model_name": "Energysaver 60P", "model_qualifier": "", "winter_efficiency_pct": 84.9, "summer_efficiency_pct": 77.3, "comparative_hot_water_efficiency_pct": 56.5, "output_kw_max": 17.58, "final_year_of_manufacture": 2003, "raw": ["003985", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Energysaver 60P", "", "41 319 74", "1993", "2003", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "14.65", "17.58", "", "", "84.9", "77.3", "", "56.5", "", "2", "0", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "86.6", "92.1", "", "", "", "", "91.1"]} -{"pcdb_id": 3986, "brand_name": "Glow-worm", "model_name": "Energysaver 30", "model_qualifier": "", "winter_efficiency_pct": 84.3, "summer_efficiency_pct": 76.7, "comparative_hot_water_efficiency_pct": 56.1, "output_kw_max": 8.79, "final_year_of_manufacture": 2002, "raw": ["003986", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Energysaver 30", "", "41 319 78", "1994", "2002", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "8.79", "8.79", "", "", "84.3", "76.7", "", "56.1", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "86.6", "91.6", "", "", "", "", "90.7"]} -{"pcdb_id": 3987, "brand_name": "Glow-worm", "model_name": "Energysaver 30e", "model_qualifier": "", "winter_efficiency_pct": 84.3, "summer_efficiency_pct": 76.7, "comparative_hot_water_efficiency_pct": 56.1, "output_kw_max": 8.79, "final_year_of_manufacture": 2002, "raw": ["003987", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Energysaver 30e", "", "41 319 76", "1994", "2002", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "8.79", "8.79", "", "", "84.3", "76.7", "", "56.1", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "86.6", "91.6", "", "", "", "", "90.7"]} -{"pcdb_id": 3988, "brand_name": "Glow-worm", "model_name": "Energysaver 40e", "model_qualifier": "", "winter_efficiency_pct": 84.4, "summer_efficiency_pct": 76.8, "comparative_hot_water_efficiency_pct": 56.1, "output_kw_max": 11.72, "final_year_of_manufacture": 2002, "raw": ["003988", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Energysaver 40e", "", "41 319 77", "1994", "2002", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "8.79", "11.72", "", "", "84.4", "76.8", "", "56.1", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "86.6", "91.9", "", "", "", "", "90.9"]} -{"pcdb_id": 3989, "brand_name": "Glow-worm", "model_name": "Swiftflow 100e", "model_qualifier": "", "winter_efficiency_pct": 77.5, "summer_efficiency_pct": 67.4, "comparative_hot_water_efficiency_pct": 47.4, "output_kw_max": 17.6, "final_year_of_manufacture": 1999, "raw": ["003989", "000207", "0", "2006/Jan/17 12:55", "Hepworth Heating", "Glow-worm", "Swiftflow 100e", "", "47 -313 -18", "1995", "1999", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "17.6", "17.6", "", "", "77.5", "67.4", "", "47.4", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "78.4", "79.0", "", "", "", "", "78.9"]} -{"pcdb_id": 3990, "brand_name": "Glow-worm", "model_name": "Swiftflow 80e", "model_qualifier": "", "winter_efficiency_pct": 77.5, "summer_efficiency_pct": 67.4, "comparative_hot_water_efficiency_pct": 47.4, "output_kw_max": 17.6, "final_year_of_manufacture": 1999, "raw": ["003990", "000207", "0", "2006/Jan/17 12:55", "Hepworth Heating", "Glow-worm", "Swiftflow 80e", "", "47 -313 -17", "1995", "1999", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "17.6", "17.6", "", "", "77.5", "67.4", "", "47.4", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "79.9", "77.5", "", "", "", "", "77.9"]} -{"pcdb_id": 3991, "brand_name": "Glow-worm", "model_name": "Swiftflow 75e", "model_qualifier": "", "winter_efficiency_pct": 77.4, "summer_efficiency_pct": 67.3, "comparative_hot_water_efficiency_pct": 47.3, "output_kw_max": 16.1, "final_year_of_manufacture": 1999, "raw": ["003991", "000207", "0", "2006/Jan/17 12:55", "Hepworth Heating", "Glow-worm", "Swiftflow 75e", "", "47 -313 -16", "1995", "1999", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "16.1", "16.1", "", "", "77.4", "67.3", "", "47.3", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "79.6", "77.7", "", "", "", "", "78.0"]} -{"pcdb_id": 3992, "brand_name": "Glow-worm", "model_name": "Swiftflow 120", "model_qualifier": "", "winter_efficiency_pct": 74.0, "summer_efficiency_pct": 63.9, "comparative_hot_water_efficiency_pct": 45.0, "output_kw_max": 23.5, "final_year_of_manufacture": 1999, "raw": ["003992", "000207", "0", "2006/Jan/17 12:55", "Hepworth Heating", "Glow-worm", "Swiftflow 120", "", "47 -313 -13", "1994", "1999", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "23.5", "23.5", "", "", "74.0", "63.9", "", "45.0", "", "2", "", "", "104", "2", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "78.7", "79.7", "", "", "", "", "79.6"]} -{"pcdb_id": 3993, "brand_name": "Glow-worm", "model_name": "Swiftflow 125e", "model_qualifier": "", "winter_efficiency_pct": 80.5, "summer_efficiency_pct": 70.4, "comparative_hot_water_efficiency_pct": 49.5, "output_kw_max": 23.5, "final_year_of_manufacture": 2002, "raw": ["003993", "000207", "0", "2006/Jan/17 12:55", "Hepworth Heating", "Glow-worm", "Swiftflow 125e", "", "47 -313 -19", "1998", "2002", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "23.5", "23.5", "", "", "80.5", "70.4", "", "49.5", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "80.9", "82.4", "", "", "", "", "82.2"]} -{"pcdb_id": 3994, "brand_name": "Glow-worm", "model_name": "Inset BBU 40", "model_qualifier": "", "winter_efficiency_pct": 76.4, "summer_efficiency_pct": 66.3, "comparative_hot_water_efficiency_pct": 48.4, "output_kw_max": 11.7, "final_year_of_manufacture": 2002, "raw": ["003994", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Inset BBU 40", "", "44 047 01", "1998", "2002", "1", "4", "1", "1", "0", "", "", "1", "1", "1", "5.9", "11.7", "", "", "76.4", "66.3", "", "48.4", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "78.2", "77.8", "", "", "", "", "77.8"]} -{"pcdb_id": 3995, "brand_name": "Glow-worm", "model_name": "Inset BBU 50", "model_qualifier": "", "winter_efficiency_pct": 78.5, "summer_efficiency_pct": 68.4, "comparative_hot_water_efficiency_pct": 49.9, "output_kw_max": 14.7, "final_year_of_manufacture": 2002, "raw": ["003995", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Inset BBU 50", "", "44 047 02", "1998", "2002", "1", "4", "1", "1", "0", "", "", "1", "1", "1", "11.7", "14.7", "", "", "78.5", "68.4", "", "49.9", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.1", "81.0", "", "", "", "", "80.6"]} -{"pcdb_id": 3996, "brand_name": "Glow-worm", "model_name": "45/2 BBU", "model_qualifier": "", "winter_efficiency_pct": 69.3, "summer_efficiency_pct": 59.2, "comparative_hot_water_efficiency_pct": 43.2, "output_kw_max": 13.8, "final_year_of_manufacture": 2002, "raw": ["003996", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "45/2 BBU", "", "44 315 39", "1997", "2002", "1", "4", "1", "1", "0", "", "", "1", "1", "1", "9.5", "13.8", "", "", "69.3", "59.2", "", "43.2", "", "2", "", "", "101", "2", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "76.1", "73.6", "", "", "", "", "74.1"]} -{"pcdb_id": 3997, "brand_name": "Glow-worm", "model_name": "56/2 BBU", "model_qualifier": "", "winter_efficiency_pct": 69.0, "summer_efficiency_pct": 58.9, "comparative_hot_water_efficiency_pct": 43.0, "output_kw_max": 16.5, "final_year_of_manufacture": 2002, "raw": ["003997", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "56/2 BBU", "", "44 315 40", "1997", "2002", "1", "4", "1", "1", "0", "", "", "1", "1", "1", "13.8", "16.5", "", "", "69.0", "58.9", "", "43.0", "", "2", "", "", "101", "2", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "75.5", "73.7", "", "", "", "", "74.0"]} -{"pcdb_id": 3998, "brand_name": "Glow-worm", "model_name": "56/3pp BBU", "model_qualifier": "", "winter_efficiency_pct": 75.4, "summer_efficiency_pct": 65.3, "comparative_hot_water_efficiency_pct": 47.7, "output_kw_max": 16.4, "final_year_of_manufacture": 2003, "raw": ["003998", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "56/3pp BBU", "", "44 O47 03A", "1999", "2003", "1", "4", "1", "1", "0", "", "", "1", "1", "1", "9.4", "16.4", "", "", "75.4", "65.3", "", "47.7", "", "2", "", "", "101", "2", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "80.5", "81.6", "", "", "", "", "81.4"]} -{"pcdb_id": 3999, "brand_name": "Glow-worm", "model_name": "56/3e BBU", "model_qualifier": "", "winter_efficiency_pct": 79.4, "summer_efficiency_pct": 69.3, "comparative_hot_water_efficiency_pct": 50.7, "output_kw_max": 16.4, "final_year_of_manufacture": 2003, "raw": ["003999", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "56/3e BBU", "", "44 047 04A", "1999", "2003", "1", "4", "1", "1", "0", "", "", "1", "1", "1", "9.4", "16.4", "", "", "79.4", "69.3", "", "50.7", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "80.5", "81.6", "", "", "", "", "81.4"]} -{"pcdb_id": 4000, "brand_name": "Glow-worm", "model_name": "Economy Plus 24B", "model_qualifier": "", "winter_efficiency_pct": 76.0, "summer_efficiency_pct": 65.9, "comparative_hot_water_efficiency_pct": 48.2, "output_kw_max": 7.03, "final_year_of_manufacture": 1998, "raw": ["004000", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Economy Plus 24B", "", "41- 319- 90", "1992", "1998", "1", "2", "1", "1", "0", "", "", "1", "2", "1", "", "7.03", "", "", "76.0", "65.9", "", "48.2", "", "2", "", "", "101", "2", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.9", "81.4", "", "", "", "", "81.5"]} -{"pcdb_id": 4001, "brand_name": "Glow-worm", "model_name": "Economy Plus 30B", "model_qualifier": "", "winter_efficiency_pct": 72.2, "summer_efficiency_pct": 62.1, "comparative_hot_water_efficiency_pct": 45.4, "output_kw_max": 8.79, "final_year_of_manufacture": 2002, "raw": ["004001", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Economy Plus 30B", "", "41- 319- 01", "1992", "2002", "1", "2", "1", "1", "0", "", "", "1", "2", "1", "5.86", "8.79", "", "", "72.2", "62.1", "", "45.4", "", "2", "", "", "101", "2", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "78.0", "77.6", "", "", "", "", "77.7"]} -{"pcdb_id": 4002, "brand_name": "Glow-worm", "model_name": "Economy Plus 40B", "model_qualifier": "", "winter_efficiency_pct": 72.8, "summer_efficiency_pct": 62.7, "comparative_hot_water_efficiency_pct": 45.8, "output_kw_max": 11.72, "final_year_of_manufacture": 2002, "raw": ["004002", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Economy Plus 40B", "", "41- 319- 02", "1992", "2002", "1", "2", "1", "1", "0", "", "", "1", "2", "1", "8.79", "11.72", "", "", "72.8", "62.7", "", "45.8", "", "2", "", "", "101", "2", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "78.3", "78.5", "", "", "", "", "78.4"]} -{"pcdb_id": 4003, "brand_name": "Glow-worm", "model_name": "Economy Plus 50B", "model_qualifier": "", "winter_efficiency_pct": 74.0, "summer_efficiency_pct": 63.9, "comparative_hot_water_efficiency_pct": 46.7, "output_kw_max": 14.65, "final_year_of_manufacture": 2002, "raw": ["004003", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Economy Plus 50B", "", "41- 319- 03", "1992", "2002", "1", "2", "1", "1", "0", "", "", "1", "2", "1", "11.72", "14.65", "", "", "74.0", "63.9", "", "46.7", "", "2", "", "", "101", "2", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.0", "78.3", "", "", "", "", "78.8"]} -{"pcdb_id": 4004, "brand_name": "Glow-worm", "model_name": "Economy Plus 60B", "model_qualifier": "", "winter_efficiency_pct": 76.5, "summer_efficiency_pct": 66.4, "comparative_hot_water_efficiency_pct": 48.5, "output_kw_max": 17.59, "final_year_of_manufacture": 1998, "raw": ["004004", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Economy Plus 60B", "", "41- 319- 04", "1992", "1998", "1", "2", "1", "1", "0", "", "", "1", "2", "1", "14.65", "17.59", "", "", "76.5", "66.4", "", "48.5", "", "2", "", "", "101", "2", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.9", "82.3", "", "", "", "", "82.2"]} -{"pcdb_id": 4005, "brand_name": "Glow-worm", "model_name": "Economy Plus 30C", "model_qualifier": "", "winter_efficiency_pct": 73.3, "summer_efficiency_pct": 63.2, "comparative_hot_water_efficiency_pct": 46.2, "output_kw_max": 8.79, "final_year_of_manufacture": 2002, "raw": ["004005", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Economy Plus 30C", "", "41- 319- 37", "1992", "2002", "1", "2", "1", "1", "0", "", "", "1", "1", "1", "5.86", "8.79", "", "", "73.3", "63.2", "", "46.2", "", "2", "", "", "101", "2", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "78.9", "78.9", "", "", "", "", "78.9"]} -{"pcdb_id": 4006, "brand_name": "Glow-worm", "model_name": "Economy Plus 40C", "model_qualifier": "", "winter_efficiency_pct": 72.8, "summer_efficiency_pct": 62.7, "comparative_hot_water_efficiency_pct": 45.8, "output_kw_max": 11.7, "final_year_of_manufacture": 2002, "raw": ["004006", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Economy Plus 40C", "", "41- 319- 38", "1992", "2002", "1", "2", "1", "1", "0", "", "", "1", "1", "1", "8.8", "11.7", "", "", "72.8", "62.7", "", "45.8", "", "2", "", "", "101", "2", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "78.7", "78.1", "", "", "", "", "78.2"]} -{"pcdb_id": 4007, "brand_name": "Glow-worm", "model_name": "Economy Plus 50C", "model_qualifier": "", "winter_efficiency_pct": 73.3, "summer_efficiency_pct": 63.2, "comparative_hot_water_efficiency_pct": 46.2, "output_kw_max": 14.65, "final_year_of_manufacture": 2002, "raw": ["004007", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Economy Plus 50C", "", "41- 319- 39", "1992", "2002", "1", "2", "1", "1", "0", "", "", "1", "1", "1", "11.72", "14.65", "", "", "73.3", "63.2", "", "46.2", "", "2", "", "", "101", "2", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "78.8", "79.0", "", "", "", "", "79.0"]} -{"pcdb_id": 4008, "brand_name": "Glow-worm", "model_name": "Economy Plus 60C", "model_qualifier": "", "winter_efficiency_pct": 74.7, "summer_efficiency_pct": 64.6, "comparative_hot_water_efficiency_pct": 47.2, "output_kw_max": 17.59, "final_year_of_manufacture": 1998, "raw": ["004008", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Economy Plus 60C", "", "41- 319- 40", "1992", "1998", "1", "2", "1", "1", "0", "", "", "1", "1", "1", "14.65", "17.59", "", "", "74.7", "64.6", "", "47.2", "", "2", "", "", "101", "2", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "80.0", "80.5", "", "", "", "", "80.4"]} -{"pcdb_id": 4009, "brand_name": "Glow-worm", "model_name": "Economy Plus 24F", "model_qualifier": "", "winter_efficiency_pct": 78.1, "summer_efficiency_pct": 68.0, "comparative_hot_water_efficiency_pct": 49.7, "output_kw_max": 7.03, "final_year_of_manufacture": 1998, "raw": ["004009", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Economy Plus 24F", "", "41- 319- 28", "1992", "1998", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "", "7.03", "", "", "78.1", "68.0", "", "49.7", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.4", "78.1", "", "", "", "", "78.7"]} -{"pcdb_id": 4010, "brand_name": "Glow-worm", "model_name": "Economy Plus 30F", "model_qualifier": "", "winter_efficiency_pct": 76.6, "summer_efficiency_pct": 66.5, "comparative_hot_water_efficiency_pct": 48.5, "output_kw_max": 8.79, "final_year_of_manufacture": 2002, "raw": ["004010", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Economy Plus 30F", "", "41- 319- 29", "1992", "2002", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "5.86", "8.79", "", "", "76.6", "66.5", "", "48.5", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "78.5", "77.8", "", "", "", "", "78.0"]} -{"pcdb_id": 4011, "brand_name": "Glow-worm", "model_name": "Economy Plus 40F", "model_qualifier": "", "winter_efficiency_pct": 77.9, "summer_efficiency_pct": 67.8, "comparative_hot_water_efficiency_pct": 49.5, "output_kw_max": 11.72, "final_year_of_manufacture": 2002, "raw": ["004011", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Economy Plus 40F", "", "41- 319- 30", "1992", "2002", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "8.79", "11.72", "", "", "77.9", "67.8", "", "49.5", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.9", "79.1", "", "", "", "", "79.3"]} -{"pcdb_id": 4012, "brand_name": "Glow-worm", "model_name": "Economy Plus 50F", "model_qualifier": "", "winter_efficiency_pct": 77.2, "summer_efficiency_pct": 67.1, "comparative_hot_water_efficiency_pct": 49.0, "output_kw_max": 14.65, "final_year_of_manufacture": 2002, "raw": ["004012", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Economy Plus 50F", "", "41- 319- 31", "1992", "2002", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "11.72", "14.65", "", "", "77.2", "67.1", "", "49.0", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "78.9", "78.7", "", "", "", "", "78.7"]} -{"pcdb_id": 4013, "brand_name": "Glow-worm", "model_name": "Economy Plus 60F", "model_qualifier": "", "winter_efficiency_pct": 76.7, "summer_efficiency_pct": 66.6, "comparative_hot_water_efficiency_pct": 48.7, "output_kw_max": 17.58, "final_year_of_manufacture": 2002, "raw": ["004013", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Economy Plus 60F", "", "41- 319- 63", "1992", "2002", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "14.65", "17.58", "", "", "76.7", "66.6", "", "48.7", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "78.4", "78.3", "", "", "", "", "78.3"]} -{"pcdb_id": 4014, "brand_name": "Glow-worm", "model_name": "Economy Plus 80F", "model_qualifier": "", "winter_efficiency_pct": 78.5, "summer_efficiency_pct": 68.4, "comparative_hot_water_efficiency_pct": 50.0, "output_kw_max": 23.45, "final_year_of_manufacture": 2002, "raw": ["004014", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Economy Plus 80F", "", "41- 319- 64", "1992", "2002", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "17.58", "23.45", "", "", "78.5", "68.4", "", "50.0", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.2", "79.1", "", "", "", "", "79.5"]} -{"pcdb_id": 4015, "brand_name": "Glow-worm", "model_name": "Hideaway 40", "model_qualifier": "", "winter_efficiency_pct": 71.7, "summer_efficiency_pct": 61.6, "comparative_hot_water_efficiency_pct": 45.0, "output_kw_max": 11.7, "final_year_of_manufacture": 2003, "raw": ["004015", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Hideaway 40", "", "44 313 17", "1997", "2003", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "8.8", "11.7", "", "", "71.7", "61.6", "", "45.0", "", "2", "", "", "101", "2", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "78.6", "76.0", "", "", "", "", "76.5"]} -{"pcdb_id": 4016, "brand_name": "Glow-worm", "model_name": "Hideaway 50", "model_qualifier": "", "winter_efficiency_pct": 71.9, "summer_efficiency_pct": 61.8, "comparative_hot_water_efficiency_pct": 45.1, "output_kw_max": 14.7, "final_year_of_manufacture": 2003, "raw": ["004016", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Hideaway 50", "", "44 313 15", "1997", "2003", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "11.7", "14.7", "", "", "71.9", "61.8", "", "45.1", "", "2", "", "", "101", "2", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "78.5", "76.5", "", "", "", "", "76.9"]} -{"pcdb_id": 4017, "brand_name": "Glow-worm", "model_name": "Hideaway 60", "model_qualifier": "", "winter_efficiency_pct": 72.2, "summer_efficiency_pct": 62.1, "comparative_hot_water_efficiency_pct": 45.4, "output_kw_max": 16.7, "final_year_of_manufacture": 2003, "raw": ["004017", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Hideaway 60", "", "41 313 13", "1997", "2003", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "14.65", "16.7", "", "", "72.2", "62.1", "", "45.4", "", "2", "", "", "101", "2", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "78.5", "77.1", "", "", "", "", "77.4"]} -{"pcdb_id": 4018, "brand_name": "Glow-worm", "model_name": "Hideaway 70", "model_qualifier": "", "winter_efficiency_pct": 72.7, "summer_efficiency_pct": 62.6, "comparative_hot_water_efficiency_pct": 45.7, "output_kw_max": 20.5, "final_year_of_manufacture": 2003, "raw": ["004018", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Hideaway 70", "", "44 313 82", "1997", "2003", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "17.6", "20.5", "", "", "72.7", "62.6", "", "45.7", "", "2", "", "", "101", "2", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "78.7", "77.8", "", "", "", "", "78.0"]} -{"pcdb_id": 4019, "brand_name": "Glow-worm", "model_name": "Hideaway 80", "model_qualifier": "", "winter_efficiency_pct": 72.6, "summer_efficiency_pct": 62.5, "comparative_hot_water_efficiency_pct": 45.7, "output_kw_max": 23.5, "final_year_of_manufacture": 2003, "raw": ["004019", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Hideaway 80", "", "44 313 25", "1997", "2003", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "20.5", "23.5", "", "", "72.6", "62.5", "", "45.7", "", "2", "", "", "101", "2", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "78.8", "77.6", "", "", "", "", "77.8"]} -{"pcdb_id": 4020, "brand_name": "Glow-worm", "model_name": "Hideaway 90", "model_qualifier": "", "winter_efficiency_pct": 72.6, "summer_efficiency_pct": 62.5, "comparative_hot_water_efficiency_pct": 45.6, "output_kw_max": 26.4, "final_year_of_manufacture": 2003, "raw": ["004020", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Hideaway 90", "", "44 313 84", "1997", "2003", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "23.5", "26.4", "", "", "72.6", "62.5", "", "45.6", "", "2", "", "", "101", "2", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "78.7", "77.7", "", "", "", "", "77.9"]} -{"pcdb_id": 4021, "brand_name": "Glow-worm", "model_name": "Hideaway 100", "model_qualifier": "", "winter_efficiency_pct": 73.0, "summer_efficiency_pct": 62.9, "comparative_hot_water_efficiency_pct": 45.9, "output_kw_max": 29.3, "final_year_of_manufacture": 2003, "raw": ["004021", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Hideaway 100", "", "44 313 27", "1997", "2003", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "26.4", "29.3", "", "", "73.0", "62.9", "", "45.9", "", "2", "", "", "101", "2", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "78.9", "78.2", "", "", "", "", "78.3"]} -{"pcdb_id": 4022, "brand_name": "Glow-worm", "model_name": "Hideaway 120", "model_qualifier": "", "winter_efficiency_pct": 73.9, "summer_efficiency_pct": 63.8, "comparative_hot_water_efficiency_pct": 46.6, "output_kw_max": 35.2, "final_year_of_manufacture": 2003, "raw": ["004022", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Hideaway 120", "", "44 313 29", "1997", "2003", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "29.3", "35.2", "", "", "73.9", "63.8", "", "46.6", "", "2", "", "", "101", "2", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.6", "79.4", "", "", "", "", "79.4"]} -{"pcdb_id": 4023, "brand_name": "Glow-worm", "model_name": "Hideaway 40B", "model_qualifier": "", "winter_efficiency_pct": 72.4, "summer_efficiency_pct": 62.3, "comparative_hot_water_efficiency_pct": 45.5, "output_kw_max": 11.7, "final_year_of_manufacture": 2003, "raw": ["004023", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Hideaway 40B", "", "44 313 16", "1997", "2003", "1", "1", "1", "1", "0", "", "", "1", "2", "1", "8.8", "11.7", "", "", "72.4", "62.3", "", "45.5", "", "2", "", "", "101", "2", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.4", "76.7", "", "", "", "", "77.2"]} -{"pcdb_id": 4024, "brand_name": "Glow-worm", "model_name": "Hideaway 50B", "model_qualifier": "", "winter_efficiency_pct": 72.3, "summer_efficiency_pct": 62.2, "comparative_hot_water_efficiency_pct": 45.5, "output_kw_max": 14.7, "final_year_of_manufacture": 2003, "raw": ["004024", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Hideaway 50B", "", "44 313 14", "1997", "2003", "1", "1", "1", "1", "0", "", "", "1", "2", "1", "11.7", "14.7", "", "", "72.3", "62.2", "", "45.5", "", "2", "", "", "101", "2", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "78.1", "77.8", "", "", "", "", "77.8"]} -{"pcdb_id": 4025, "brand_name": "Glow-worm", "model_name": "Hideaway 60B", "model_qualifier": "", "winter_efficiency_pct": 72.6, "summer_efficiency_pct": 62.5, "comparative_hot_water_efficiency_pct": 45.6, "output_kw_max": 16.7, "final_year_of_manufacture": 2003, "raw": ["004025", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Hideaway 60B", "", "44 313 12", "1997", "2003", "1", "1", "1", "1", "0", "", "", "1", "2", "1", "14.7", "16.7", "", "", "72.6", "62.5", "", "45.6", "", "2", "", "", "101", "2", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "78.9", "77.4", "", "", "", "", "77.7"]} -{"pcdb_id": 4026, "brand_name": "Glow-worm", "model_name": "Hideaway 70B", "model_qualifier": "", "winter_efficiency_pct": 73.4, "summer_efficiency_pct": 63.3, "comparative_hot_water_efficiency_pct": 46.2, "output_kw_max": 20.5, "final_year_of_manufacture": null, "raw": ["004026", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Hideaway 70B", "", "44 313 83", "1997", "current", "1", "1", "1", "1", "0", "", "", "1", "2", "1", "17.6", "20.5", "", "", "73.4", "63.3", "", "46.2", "", "2", "", "", "101", "2", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.2", "78.7", "", "", "", "", "78.8"]} -{"pcdb_id": 4027, "brand_name": "Glow-worm", "model_name": "Hideaway 80B", "model_qualifier": "", "winter_efficiency_pct": 73.5, "summer_efficiency_pct": 63.4, "comparative_hot_water_efficiency_pct": 46.3, "output_kw_max": 23.5, "final_year_of_manufacture": 2003, "raw": ["004027", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Hideaway 80B", "", "44 313 24", "1997", "2003", "1", "1", "1", "1", "0", "", "", "1", "2", "1", "20.5", "23.5", "", "", "73.5", "63.4", "", "46.3", "", "2", "", "", "101", "2", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.2", "79.0", "", "", "", "", "79.1"]} -{"pcdb_id": 4028, "brand_name": "Glow-worm", "model_name": "Hideaway 90B", "model_qualifier": "", "winter_efficiency_pct": 73.7, "summer_efficiency_pct": 63.6, "comparative_hot_water_efficiency_pct": 46.5, "output_kw_max": 26.4, "final_year_of_manufacture": null, "raw": ["004028", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Hideaway 90B", "", "44 313 85", "1997", "current", "1", "1", "1", "1", "0", "", "", "1", "2", "1", "23.5", "26.4", "", "", "73.7", "63.6", "", "46.5", "", "2", "", "", "101", "2", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.9", "78.7", "", "", "", "", "79.0"]} -{"pcdb_id": 4029, "brand_name": "Glow-worm", "model_name": "Hideaway 100B", "model_qualifier": "", "winter_efficiency_pct": 73.9, "summer_efficiency_pct": 63.8, "comparative_hot_water_efficiency_pct": 46.6, "output_kw_max": 29.3, "final_year_of_manufacture": 2003, "raw": ["004029", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Hideaway 100B", "", "44 313 26", "1997", "2003", "1", "1", "1", "1", "0", "", "", "1", "2", "1", "26.4", "29.3", "", "", "73.9", "63.8", "", "46.6", "", "2", "", "", "101", "2", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.5", "79.5", "", "", "", "", "79.5"]} -{"pcdb_id": 4030, "brand_name": "Glow-worm", "model_name": "Hideaway 120B", "model_qualifier": "", "winter_efficiency_pct": 72.9, "summer_efficiency_pct": 62.8, "comparative_hot_water_efficiency_pct": 45.9, "output_kw_max": 35.2, "final_year_of_manufacture": 2003, "raw": ["004030", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Hideaway 120B", "", "44 313 28", "1997", "2003", "1", "1", "1", "1", "0", "", "", "1", "2", "1", "29.3", "35.2", "", "", "72.9", "62.8", "", "45.9", "", "2", "", "", "101", "2", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.5", "77.6", "", "", "", "", "77.9"]} -{"pcdb_id": 4031, "brand_name": "Glow-worm", "model_name": "Micron 120FF", "model_qualifier": "", "winter_efficiency_pct": 79.0, "summer_efficiency_pct": 68.9, "comparative_hot_water_efficiency_pct": 50.4, "output_kw_max": 35.17, "final_year_of_manufacture": null, "raw": ["004031", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Micron 120FF", "", "41 047 23", "1999", "current", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "29.31", "35.17", "", "", "79.0", "68.9", "", "50.4", "", "2", "", "", "101", "1", "1", "97", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.8", "81.5", "", "", "", "", "81.1"]} -{"pcdb_id": 4032, "brand_name": "Glow-worm", "model_name": "Micron 30FF", "model_qualifier": "", "winter_efficiency_pct": 77.5, "summer_efficiency_pct": 67.4, "comparative_hot_water_efficiency_pct": 49.2, "output_kw_max": 8.79, "final_year_of_manufacture": 2002, "raw": ["004032", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Micron 30FF", "", "41 047 16", "1999", "2002", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "5.86", "8.79", "", "", "77.5", "67.4", "", "49.2", "", "2", "", "", "101", "1", "1", "66", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.6", "78.6", "", "", "", "", "78.8"]} -{"pcdb_id": 4033, "brand_name": "Glow-worm", "model_name": "Micron 40FF", "model_qualifier": "", "winter_efficiency_pct": 78.2, "summer_efficiency_pct": 68.1, "comparative_hot_water_efficiency_pct": 49.8, "output_kw_max": 11.72, "final_year_of_manufacture": 2002, "raw": ["004033", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Micron 40FF", "", "41 047 17", "1999", "2002", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "8.8", "11.72", "", "", "78.2", "68.1", "", "49.8", "", "2", "", "", "101", "1", "1", "66", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "80.4", "79.3", "", "", "", "", "79.5"]} -{"pcdb_id": 4035, "brand_name": "Glow-worm", "model_name": "Micron 60FF", "model_qualifier": "", "winter_efficiency_pct": 78.1, "summer_efficiency_pct": 68.0, "comparative_hot_water_efficiency_pct": 49.7, "output_kw_max": 17.58, "final_year_of_manufacture": 2002, "raw": ["004035", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Micron 60FF", "", "41 047 19", "1999", "2002", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "14.65", "17.58", "", "", "78.1", "68.0", "", "49.7", "", "2", "", "", "101", "1", "1", "71", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "80.0", "79.5", "", "", "", "", "79.6"]} -{"pcdb_id": 4036, "brand_name": "Glow-worm", "model_name": "Micron 70FF", "model_qualifier": "", "winter_efficiency_pct": 78.3, "summer_efficiency_pct": 68.2, "comparative_hot_water_efficiency_pct": 49.8, "output_kw_max": 20.51, "final_year_of_manufacture": 2002, "raw": ["004036", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Micron 70FF", "", "41 047 20", "1999", "2002", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "17.58", "20.51", "", "", "78.3", "68.2", "", "49.8", "", "2", "", "", "101", "1", "1", "81", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.8", "79.9", "", "", "", "", "79.9"]} -{"pcdb_id": 4037, "brand_name": "Glow-worm", "model_name": "Micron100FF", "model_qualifier": "", "winter_efficiency_pct": 78.4, "summer_efficiency_pct": 68.3, "comparative_hot_water_efficiency_pct": 49.9, "output_kw_max": 29.31, "final_year_of_manufacture": 2002, "raw": ["004037", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Micron100FF", "", "41 047 22", "1999", "2002", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "23.45", "29.31", "", "", "78.4", "68.3", "", "49.9", "", "2", "", "", "101", "1", "1", "71", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "80.2", "79.8", "", "", "", "", "79.9"]} -{"pcdb_id": 4038, "brand_name": "Glow-worm", "model_name": "Micron 80FF", "model_qualifier": "", "winter_efficiency_pct": 78.1, "summer_efficiency_pct": 68.0, "comparative_hot_water_efficiency_pct": 49.7, "output_kw_max": 23.45, "final_year_of_manufacture": 2002, "raw": ["004038", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Micron 80FF", "", "41 047 21", "1999", "2002", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "20.51", "23.45", "", "", "78.1", "68.0", "", "49.7", "", "2", "", "", "101", "1", "1", "81", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.9", "79.5", "", "", "", "", "79.6"]} -{"pcdb_id": 4039, "brand_name": "Glow-worm", "model_name": "Ultimate 50BF/LP", "model_qualifier": "", "winter_efficiency_pct": 75.7, "summer_efficiency_pct": 65.6, "comparative_hot_water_efficiency_pct": 47.9, "output_kw_max": 14.65, "final_year_of_manufacture": 2002, "raw": ["004039", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Ultimate 50BF/LP", "", "", "1993", "2002", "2", "2", "1", "1", "0", "", "", "1", "2", "1", "14.65", "14.65", "", "", "75.7", "65.6", "", "47.9", "", "2", "0", "", "101", "2", "1", "1", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.6", "81.0", "", "", "", "", "81.1"]} -{"pcdb_id": 4040, "brand_name": "Glow-worm", "model_name": "Ultimate 80FF/LP", "model_qualifier": "", "winter_efficiency_pct": 80.7, "summer_efficiency_pct": 70.6, "comparative_hot_water_efficiency_pct": 51.6, "output_kw_max": 21.98, "final_year_of_manufacture": null, "raw": ["004040", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Ultimate 80FF/LP", "", "", "1993", "current", "2", "2", "1", "1", "0", "", "", "1", "2", "2", "21.98", "21.98", "", "", "80.7", "70.6", "", "51.6", "", "2", "0", "", "101", "1", "1", "71", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.2", "82.4", "", "", "", "", "82.4"]} -{"pcdb_id": 4041, "brand_name": "Glow-worm", "model_name": "Ultimate 60FF/LP", "model_qualifier": "", "winter_efficiency_pct": 78.4, "summer_efficiency_pct": 68.3, "comparative_hot_water_efficiency_pct": 49.9, "output_kw_max": 17.59, "final_year_of_manufacture": 2002, "raw": ["004041", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Ultimate 60FF/LP", "", "", "1993", "2002", "2", "2", "1", "1", "0", "", "", "1", "2", "2", "17.59", "17.59", "", "", "78.4", "68.3", "", "49.9", "", "2", "0", "", "101", "1", "1", "71", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "80.4", "79.6", "", "", "", "", "79.7"]} -{"pcdb_id": 4042, "brand_name": "Glow-worm", "model_name": "Ultimate 50FF/LP", "model_qualifier": "", "winter_efficiency_pct": 81.0, "summer_efficiency_pct": 70.9, "comparative_hot_water_efficiency_pct": 51.8, "output_kw_max": 14.65, "final_year_of_manufacture": null, "raw": ["004042", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Ultimate 50FF/LP", "", "", "1993", "current", "2", "2", "1", "1", "0", "", "", "1", "2", "2", "14.65", "14.65", "", "", "81.0", "70.9", "", "51.8", "", "2", "0", "", "101", "1", "1", "56", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.4", "82.7", "", "", "", "", "82.7"]} -{"pcdb_id": 4043, "brand_name": "Glow-worm", "model_name": "Ultimate 40FF/LP", "model_qualifier": "", "winter_efficiency_pct": 78.9, "summer_efficiency_pct": 68.8, "comparative_hot_water_efficiency_pct": 50.3, "output_kw_max": 11.72, "final_year_of_manufacture": 2002, "raw": ["004043", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Ultimate 40FF/LP", "", "", "1993", "2002", "2", "2", "1", "1", "0", "", "", "1", "2", "2", "11.72", "11.72", "", "", "78.9", "68.8", "", "50.3", "", "2", "0", "", "101", "1", "1", "56", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "80.8", "80.3", "", "", "", "", "80.4"]} -{"pcdb_id": 4044, "brand_name": "Glow-worm", "model_name": "Ultimate 30FF/LP", "model_qualifier": "", "winter_efficiency_pct": 78.9, "summer_efficiency_pct": 68.8, "comparative_hot_water_efficiency_pct": 50.3, "output_kw_max": 8.79, "final_year_of_manufacture": 2002, "raw": ["004044", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Ultimate 30FF/LP", "", "", "1993", "2002", "2", "2", "1", "1", "0", "", "", "1", "2", "2", "8.79", "8.79", "", "", "78.9", "68.8", "", "50.3", "", "2", "0", "", "101", "1", "1", "56", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "80.0", "81.0", "", "", "", "", "80.9"]} -{"pcdb_id": 4045, "brand_name": "Glow-worm", "model_name": "Ultimate 100FF", "model_qualifier": "", "winter_efficiency_pct": 78.4, "summer_efficiency_pct": 68.3, "comparative_hot_water_efficiency_pct": 49.9, "output_kw_max": 29.31, "final_year_of_manufacture": 2002, "raw": ["004045", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Ultimate 100FF", "", "41 319 61", "1994", "2002", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "23.45", "29.31", "", "", "78.4", "68.3", "", "49.9", "", "2", "", "", "101", "1", "1", "71", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "80.2", "79.8", "", "", "", "", "79.9"]} -{"pcdb_id": 4046, "brand_name": "Glow-worm", "model_name": "Ultimate 80FF", "model_qualifier": "", "winter_efficiency_pct": 77.2, "summer_efficiency_pct": 67.1, "comparative_hot_water_efficiency_pct": 49.0, "output_kw_max": 23.45, "final_year_of_manufacture": 2002, "raw": ["004046", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Ultimate 80FF", "", "41 319 60", "1993", "2002", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "20.52", "23.45", "", "", "77.2", "67.1", "", "49.0", "", "2", "", "", "101", "1", "1", "71", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.2", "78.5", "", "", "", "", "78.6"]} -{"pcdb_id": 4047, "brand_name": "Glow-worm", "model_name": "Ultimate 50FF", "model_qualifier": "", "winter_efficiency_pct": 76.9, "summer_efficiency_pct": 66.8, "comparative_hot_water_efficiency_pct": 48.8, "output_kw_max": 14.65, "final_year_of_manufacture": 2002, "raw": ["004047", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Ultimate 50FF", "", "41 319 58", "1993", "2002", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "11.72", "14.65", "", "", "76.9", "66.8", "", "48.8", "", "2", "", "", "101", "1", "1", "56", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "78.7", "78.3", "", "", "", "", "78.4"]} -{"pcdb_id": 4048, "brand_name": "Glow-worm", "model_name": "Ultimate 60FF", "model_qualifier": "", "winter_efficiency_pct": 77.5, "summer_efficiency_pct": 67.4, "comparative_hot_water_efficiency_pct": 49.2, "output_kw_max": 17.59, "final_year_of_manufacture": 2002, "raw": ["004048", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Ultimate 60FF", "", "41 319 59", "1993", "2002", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "14.65", "17.59", "", "", "77.5", "67.4", "", "49.2", "", "2", "", "", "101", "1", "1", "71", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "78.8", "79.3", "", "", "", "", "79.2"]} -{"pcdb_id": 4049, "brand_name": "Glow-worm", "model_name": "Ultimate 120FF", "model_qualifier": "", "winter_efficiency_pct": 79.0, "summer_efficiency_pct": 68.9, "comparative_hot_water_efficiency_pct": 50.4, "output_kw_max": 35.17, "final_year_of_manufacture": null, "raw": ["004049", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Ultimate 120FF", "", "41 319 75", "1994", "current", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "29.3", "35.17", "", "", "79.0", "68.9", "", "50.4", "", "2", "", "", "101", "1", "1", "97", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.8", "81.5", "", "", "", "", "81.1"]} -{"pcdb_id": 4050, "brand_name": "Glow-worm", "model_name": "Ultimate 70FF", "model_qualifier": "", "winter_efficiency_pct": 78.0, "summer_efficiency_pct": 67.9, "comparative_hot_water_efficiency_pct": 49.6, "output_kw_max": 20.52, "final_year_of_manufacture": 2002, "raw": ["004050", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Ultimate 70FF", "", "41 319 59", "1994", "2002", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "17.58", "20.52", "", "", "78.0", "67.9", "", "49.6", "", "2", "", "", "101", "1", "1", "71", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.6", "79.6", "", "", "", "", "79.6"]} -{"pcdb_id": 4051, "brand_name": "Glow-worm", "model_name": "Ultimate 30FF", "model_qualifier": "", "winter_efficiency_pct": 80.8, "summer_efficiency_pct": 70.7, "comparative_hot_water_efficiency_pct": 51.6, "output_kw_max": 8.79, "final_year_of_manufacture": null, "raw": ["004051", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Ultimate 30FF", "", "41 319 56", "1993", "current", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "5.86", "8.79", "", "", "80.8", "70.7", "", "51.6", "", "2", "", "", "101", "1", "1", "56", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.4", "82.4", "", "", "", "", "82.4"]} -{"pcdb_id": 4052, "brand_name": "Glow-worm", "model_name": "Ultimate 40FF", "model_qualifier": "", "winter_efficiency_pct": 76.3, "summer_efficiency_pct": 66.2, "comparative_hot_water_efficiency_pct": 48.4, "output_kw_max": 11.72, "final_year_of_manufacture": 2002, "raw": ["004052", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Ultimate 40FF", "", "41 319 57", "1993", "2002", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "8.79", "11.72", "", "", "76.3", "66.2", "", "48.4", "", "2", "", "", "101", "1", "1", "56", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.0", "76.9", "", "", "", "", "77.3"]} -{"pcdb_id": 4053, "brand_name": "Glow-worm", "model_name": "Fuelsaver Complheat 40", "model_qualifier": "", "winter_efficiency_pct": 77.6, "summer_efficiency_pct": 67.5, "comparative_hot_water_efficiency_pct": 49.3, "output_kw_max": 11.7, "final_year_of_manufacture": 2002, "raw": ["004053", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Fuelsaver Complheat 40", "", "41-319-20", "1991", "2002", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "8.8", "11.7", "", "", "77.6", "67.5", "", "49.3", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.6", "78.7", "", "", "", "", "78.9"]} -{"pcdb_id": 4054, "brand_name": "Glow-worm", "model_name": "Fuelsaver Complheat 65", "model_qualifier": "", "winter_efficiency_pct": 80.0, "summer_efficiency_pct": 69.9, "comparative_hot_water_efficiency_pct": 51.0, "output_kw_max": 19.1, "final_year_of_manufacture": 2002, "raw": ["004054", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Fuelsaver Complheat 65", "", "41-319-21", "1991", "2002", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "16.1", "19.1", "", "", "80.0", "69.9", "", "51.0", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.3", "81.9", "", "", "", "", "81.8"]} -{"pcdb_id": 4055, "brand_name": "Glow-worm", "model_name": "Fuelsaver Complheat 30", "model_qualifier": "", "winter_efficiency_pct": 77.4, "summer_efficiency_pct": 67.3, "comparative_hot_water_efficiency_pct": 49.2, "output_kw_max": 8.8, "final_year_of_manufacture": 2002, "raw": ["004055", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Fuelsaver Complheat 30", "", "41-319-14", "1991", "2002", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "5.9", "8.8", "", "", "77.4", "67.3", "", "49.2", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "80.1", "77.9", "", "", "", "", "78.3"]} -{"pcdb_id": 4056, "brand_name": "Glow-worm", "model_name": "Fuelsaver Complheat 55", "model_qualifier": "", "winter_efficiency_pct": 77.3, "summer_efficiency_pct": 67.2, "comparative_hot_water_efficiency_pct": 49.1, "output_kw_max": 16.1, "final_year_of_manufacture": 2002, "raw": ["004056", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Fuelsaver Complheat 55", "", "41-319-19", "1991", "2002", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "11.7", "16.1", "", "", "77.3", "67.2", "", "49.1", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.3", "78.6", "", "", "", "", "78.7"]} -{"pcdb_id": 4057, "brand_name": "Glow-worm", "model_name": "Fuelsaver Complheat 80", "model_qualifier": "", "winter_efficiency_pct": 80.1, "summer_efficiency_pct": 70.0, "comparative_hot_water_efficiency_pct": 51.1, "output_kw_max": 23.4, "final_year_of_manufacture": 2002, "raw": ["004057", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Fuelsaver Complheat 80", "", "41-319-18", "1991", "2002", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "19.1", "23.4", "", "", "80.1", "70.0", "", "51.1", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "80.9", "82.5", "", "", "", "", "82.2"]} -{"pcdb_id": 4058, "brand_name": "Glow-worm", "model_name": "Compact 75e", "model_qualifier": "", "winter_efficiency_pct": 78.4, "summer_efficiency_pct": 68.3, "comparative_hot_water_efficiency_pct": 48.0, "output_kw_max": 16.1, "final_year_of_manufacture": 2003, "raw": ["004058", "000207", "0", "2006/Jan/17 12:55", "Hepworth Heating", "Glow-worm", "Compact 75e", "", "47-047-06A", "1999", "2003", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "16.1", "16.1", "", "", "78.4", "68.3", "", "48.0", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.0", "78.1", "", "", "", "", "78.7"]} -{"pcdb_id": 4059, "brand_name": "Glow-worm", "model_name": "Compact 80e", "model_qualifier": "", "winter_efficiency_pct": 78.7, "summer_efficiency_pct": 68.6, "comparative_hot_water_efficiency_pct": 48.2, "output_kw_max": 17.6, "final_year_of_manufacture": 2002, "raw": ["004059", "000207", "0", "2006/Jan/17 12:55", "Hepworth Heating", "Glow-worm", "Compact 80e", "", "47-047-07A", "1999", "2002", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "17.6", "17.6", "", "", "78.7", "68.6", "", "48.2", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.5", "78.2", "", "", "", "", "78.8"]} -{"pcdb_id": 4060, "brand_name": "Glow-worm", "model_name": "Compact 80p", "model_qualifier": "", "winter_efficiency_pct": 73.1, "summer_efficiency_pct": 63.0, "comparative_hot_water_efficiency_pct": 44.3, "output_kw_max": 17.6, "final_year_of_manufacture": 2002, "raw": ["004060", "000207", "0", "2006/Jan/17 12:55", "Hepworth Heating", "Glow-worm", "Compact 80p", "", "47-047-04A", "1999", "2002", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "17.6", "17.6", "", "", "73.1", "63.0", "", "44.3", "", "2", "", "", "104", "2", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "78.9", "77.7", "", "", "", "", "77.9"]} -{"pcdb_id": 4061, "brand_name": "Glow-worm", "model_name": "Compact 100p", "model_qualifier": "", "winter_efficiency_pct": 72.5, "summer_efficiency_pct": 62.4, "comparative_hot_water_efficiency_pct": 43.9, "output_kw_max": 17.6, "final_year_of_manufacture": 2002, "raw": ["004061", "000207", "0", "2006/Jan/17 12:55", "Hepworth Heating", "Glow-worm", "Compact 100p", "", "47-047-05A", "1999", "2002", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "17.6", "17.6", "", "", "72.5", "62.4", "", "43.9", "", "2", "", "", "104", "2", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "79.6", "75.9", "", "", "", "", "76.6"]} -{"pcdb_id": 4062, "brand_name": "Glow-worm", "model_name": "Compact 75p", "model_qualifier": "", "winter_efficiency_pct": 73.0, "summer_efficiency_pct": 62.9, "comparative_hot_water_efficiency_pct": 44.2, "output_kw_max": 16.1, "final_year_of_manufacture": 2002, "raw": ["004062", "000207", "0", "2006/Jan/17 12:55", "Hepworth Heating", "Glow-worm", "Compact 75p", "", "47-047-03A", "1999", "2002", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "16.1", "16.1", "", "", "73.0", "62.9", "", "44.2", "", "2", "", "", "104", "2", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "79.8", "76.6", "", "", "", "", "77.2"]} -{"pcdb_id": 4063, "brand_name": "Glow-worm", "model_name": "Compact 100e", "model_qualifier": "", "winter_efficiency_pct": 79.1, "summer_efficiency_pct": 69.0, "comparative_hot_water_efficiency_pct": 48.5, "output_kw_max": 17.6, "final_year_of_manufacture": 2002, "raw": ["004063", "000207", "0", "2006/Jan/17 12:55", "Hepworth Heating", "Glow-worm", "Compact 100e", "", "47-047-08A", "1999", "2002", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "17.6", "17.6", "", "", "79.1", "69.0", "", "48.5", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "83.0", "77.8", "", "", "", "", "78.7"]} -{"pcdb_id": 4064, "brand_name": "Hepworth Heating", "model_name": "Halstead Buckingham III BF120", "model_qualifier": "", "winter_efficiency_pct": 72.9, "summer_efficiency_pct": 62.8, "comparative_hot_water_efficiency_pct": 45.9, "output_kw_max": 35.2, "final_year_of_manufacture": 2003, "raw": ["004064", "000019", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Hepworth Heating", "Halstead Buckingham III BF120", "", "41.333.72", "1997", "2003", "1", "1", "1", "1", "0", "", "", "1", "2", "1", "29.3", "35.2", "", "", "72.9", "62.8", "", "45.9", "", "2", "", "", "101", "2", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.5", "77.6", "", "", "", "", "77.9"]} -{"pcdb_id": 4065, "brand_name": "Hepworth Heating", "model_name": "Halstead Buckingham III BF100", "model_qualifier": "", "winter_efficiency_pct": 73.9, "summer_efficiency_pct": 63.8, "comparative_hot_water_efficiency_pct": 46.6, "output_kw_max": 29.3, "final_year_of_manufacture": 2003, "raw": ["004065", "000019", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Hepworth Heating", "Halstead Buckingham III BF100", "", "41.333.71", "1997", "2003", "1", "1", "1", "1", "0", "", "", "1", "2", "1", "26.4", "29.3", "", "", "73.9", "63.8", "", "46.6", "", "2", "", "", "101", "2", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.5", "79.5", "", "", "", "", "79.5"]} -{"pcdb_id": 4066, "brand_name": "Hepworth Heating", "model_name": "Halstead Buckingham III BF80", "model_qualifier": "", "winter_efficiency_pct": 73.5, "summer_efficiency_pct": 63.4, "comparative_hot_water_efficiency_pct": 46.3, "output_kw_max": 23.5, "final_year_of_manufacture": 2003, "raw": ["004066", "000019", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Hepworth Heating", "Halstead Buckingham III BF80", "", "41.333.70", "1997", "2003", "1", "1", "1", "1", "0", "", "", "1", "2", "1", "20.5", "23.5", "", "", "73.5", "63.4", "", "46.3", "", "2", "", "", "101", "2", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.2", "79.0", "", "", "", "", "79.1"]} -{"pcdb_id": 4067, "brand_name": "Hepworth Heating", "model_name": "Halstead Buckingham III BF70", "model_qualifier": "", "winter_efficiency_pct": 73.4, "summer_efficiency_pct": 63.3, "comparative_hot_water_efficiency_pct": 46.2, "output_kw_max": 20.5, "final_year_of_manufacture": 2003, "raw": ["004067", "000019", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Hepworth Heating", "Halstead Buckingham III BF70", "", "41.333.69", "1997", "2003", "1", "1", "1", "1", "0", "", "", "1", "2", "1", "17.6", "20.5", "", "", "73.4", "63.3", "", "46.2", "", "2", "", "", "101", "2", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.2", "78.7", "", "", "", "", "78.8"]} -{"pcdb_id": 4068, "brand_name": "Hepworth Heating", "model_name": "Halstead Buckingham III BF 60", "model_qualifier": "", "winter_efficiency_pct": 72.6, "summer_efficiency_pct": 62.5, "comparative_hot_water_efficiency_pct": 45.6, "output_kw_max": 16.7, "final_year_of_manufacture": 2003, "raw": ["004068", "000019", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Hepworth Heating", "Halstead Buckingham III BF 60", "", "41.333.68", "1997", "2003", "1", "1", "1", "1", "0", "", "", "1", "2", "1", "14.7", "16.7", "", "", "72.6", "62.5", "", "45.6", "", "2", "", "", "101", "2", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "78.9", "77.4", "", "", "", "", "77.7"]} -{"pcdb_id": 4069, "brand_name": "Hepworth Heating", "model_name": "Halstead Buckingham III BF50", "model_qualifier": "", "winter_efficiency_pct": 72.3, "summer_efficiency_pct": 62.2, "comparative_hot_water_efficiency_pct": 45.5, "output_kw_max": 14.7, "final_year_of_manufacture": 2003, "raw": ["004069", "000019", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Hepworth Heating", "Halstead Buckingham III BF50", "", "41 333 67", "1997", "2003", "1", "1", "1", "1", "0", "", "", "1", "2", "1", "11.7", "14.7", "", "", "72.3", "62.2", "", "45.5", "", "2", "", "", "101", "2", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "78.1", "77.8", "", "", "", "", "77.8"]} -{"pcdb_id": 4070, "brand_name": "Hepworth Heating", "model_name": "Halstead Buckingham III BF40", "model_qualifier": "", "winter_efficiency_pct": 72.4, "summer_efficiency_pct": 62.3, "comparative_hot_water_efficiency_pct": 45.5, "output_kw_max": 11.7, "final_year_of_manufacture": 2003, "raw": ["004070", "000019", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Hepworth Heating", "Halstead Buckingham III BF40", "", "41 333 66", "1997", "2003", "1", "1", "1", "1", "0", "", "", "1", "2", "1", "8.8", "11.7", "", "", "72.4", "62.3", "", "45.5", "", "2", "", "", "101", "2", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.4", "76.7", "", "", "", "", "77.2"]} -{"pcdb_id": 4071, "brand_name": "Hepworth Heating", "model_name": "Halstead Buckingham III CF120", "model_qualifier": "", "winter_efficiency_pct": 73.9, "summer_efficiency_pct": 63.8, "comparative_hot_water_efficiency_pct": 46.6, "output_kw_max": 35.2, "final_year_of_manufacture": 2003, "raw": ["004071", "000019", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Hepworth Heating", "Halstead Buckingham III CF120", "", "41.333.65", "1997", "2003", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "29.3", "35.2", "", "", "73.9", "63.8", "", "46.6", "", "2", "", "", "101", "2", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.6", "79.4", "", "", "", "", "79.4"]} -{"pcdb_id": 4072, "brand_name": "Hepworth Heating", "model_name": "Halstead Buckingham III CF100", "model_qualifier": "", "winter_efficiency_pct": 73.0, "summer_efficiency_pct": 62.9, "comparative_hot_water_efficiency_pct": 45.9, "output_kw_max": 29.3, "final_year_of_manufacture": 2003, "raw": ["004072", "000019", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Hepworth Heating", "Halstead Buckingham III CF100", "", "41.333.64", "1997", "2003", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "26.4", "29.3", "", "", "73.0", "62.9", "", "45.9", "", "2", "", "", "101", "2", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "78.9", "78.2", "", "", "", "", "78.3"]} -{"pcdb_id": 4073, "brand_name": "Hepworth Heating", "model_name": "Halstead Buckingham III CF80", "model_qualifier": "", "winter_efficiency_pct": 72.6, "summer_efficiency_pct": 62.5, "comparative_hot_water_efficiency_pct": 45.7, "output_kw_max": 23.5, "final_year_of_manufacture": 2003, "raw": ["004073", "000019", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Hepworth Heating", "Halstead Buckingham III CF80", "", "41.333.63", "1997", "2003", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "20.5", "23.5", "", "", "72.6", "62.5", "", "45.7", "", "2", "", "", "101", "2", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "78.8", "77.6", "", "", "", "", "77.8"]} -{"pcdb_id": 4074, "brand_name": "Hepworth Heating", "model_name": "Halstead Buckingham III CF70", "model_qualifier": "", "winter_efficiency_pct": 72.7, "summer_efficiency_pct": 62.6, "comparative_hot_water_efficiency_pct": 45.7, "output_kw_max": 20.5, "final_year_of_manufacture": 2003, "raw": ["004074", "000019", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Hepworth Heating", "Halstead Buckingham III CF70", "", "41.333.62", "1997", "2003", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "17.6", "20.5", "", "", "72.7", "62.6", "", "45.7", "", "2", "", "", "101", "2", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "78.7", "77.8", "", "", "", "", "78.0"]} -{"pcdb_id": 4075, "brand_name": "Hepworth Heating", "model_name": "Halstead Buckingham III CF60", "model_qualifier": "", "winter_efficiency_pct": 72.2, "summer_efficiency_pct": 62.1, "comparative_hot_water_efficiency_pct": 45.4, "output_kw_max": 16.7, "final_year_of_manufacture": 2003, "raw": ["004075", "000019", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Hepworth Heating", "Halstead Buckingham III CF60", "", "41.333.61", "1997", "2003", "1", "1", "1", "1", "0", "", "", "1", "2", "1", "14.65", "16.7", "", "", "72.2", "62.1", "", "45.4", "", "2", "", "", "101", "2", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "78.5", "77.1", "", "", "", "", "77.4"]} -{"pcdb_id": 4076, "brand_name": "Hepworth Heating", "model_name": "Halstead Buckingham III CF50", "model_qualifier": "", "winter_efficiency_pct": 71.9, "summer_efficiency_pct": 61.8, "comparative_hot_water_efficiency_pct": 45.1, "output_kw_max": 14.7, "final_year_of_manufacture": 2003, "raw": ["004076", "000019", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Hepworth Heating", "Halstead Buckingham III CF50", "", "41 333 60", "1997", "2003", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "11.7", "14.7", "", "", "71.9", "61.8", "", "45.1", "", "2", "", "", "101", "2", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "78.5", "76.5", "", "", "", "", "76.9"]} -{"pcdb_id": 4077, "brand_name": "Hepworth Heating", "model_name": "Halstead Buckingham III CF40", "model_qualifier": "", "winter_efficiency_pct": 71.7, "summer_efficiency_pct": 61.6, "comparative_hot_water_efficiency_pct": 45.0, "output_kw_max": 11.7, "final_year_of_manufacture": 2003, "raw": ["004077", "000019", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Hepworth Heating", "Halstead Buckingham III CF40", "", "44 333 59", "1997", "2003", "1", "1", "1", "1", "0", "", "", "1", "2", "1", "8.8", "11.7", "", "", "71.7", "61.6", "", "45.0", "", "2", "", "", "101", "2", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "78.6", "76.0", "", "", "", "", "76.5"]} -{"pcdb_id": 4078, "brand_name": "Saunier Duval", "model_name": "Xeon 80ff", "model_qualifier": "", "winter_efficiency_pct": 77.2, "summer_efficiency_pct": 67.1, "comparative_hot_water_efficiency_pct": 49.0, "output_kw_max": 23.45, "final_year_of_manufacture": 2003, "raw": ["004078", "000206", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Saunier Duval", "Xeon 80ff", "", "", "1999", "2003", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "20.52", "23.45", "", "", "77.2", "67.1", "", "49.0", "", "2", "", "", "101", "1", "1", "71", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.2", "78.5", "", "", "", "", "78.6"]} -{"pcdb_id": 4081, "brand_name": "Saunier Duval", "model_name": "Xeon40ff", "model_qualifier": "", "winter_efficiency_pct": 76.3, "summer_efficiency_pct": 66.2, "comparative_hot_water_efficiency_pct": 48.4, "output_kw_max": 11.72, "final_year_of_manufacture": 2003, "raw": ["004081", "000206", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Saunier Duval", "Xeon40ff", "", "", "1999", "2003", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "8.79", "11.72", "", "", "76.3", "66.2", "", "48.4", "", "2", "", "", "101", "1", "1", "56", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.0", "76.9", "", "", "", "", "77.3"]} -{"pcdb_id": 4082, "brand_name": "Saunier Duval", "model_name": "Xeon 30ff", "model_qualifier": "", "winter_efficiency_pct": 80.8, "summer_efficiency_pct": 70.7, "comparative_hot_water_efficiency_pct": 51.6, "output_kw_max": 8.79, "final_year_of_manufacture": null, "raw": ["004082", "000206", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Saunier Duval", "Xeon 30ff", "", "", "1999", "current", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "5.86", "8.79", "", "", "80.8", "70.7", "", "51.6", "", "2", "", "", "101", "1", "1", "56", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.4", "82.4", "", "", "", "", "82.4"]} -{"pcdb_id": 4083, "brand_name": "Glow-worm", "model_name": "Ultimate 30BF", "model_qualifier": "", "winter_efficiency_pct": 73.9, "summer_efficiency_pct": 63.8, "comparative_hot_water_efficiency_pct": 46.6, "output_kw_max": 8.79, "final_year_of_manufacture": 2002, "raw": ["004083", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Ultimate 30BF", "", "41 319 51", "1993", "2002", "1", "2", "1", "1", "0", "", "", "1", "2", "1", "5.86", "8.79", "", "", "73.9", "63.8", "", "46.6", "", "2", "", "", "101", "2", "1", "1", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.6", "79.5", "", "", "", "", "79.5"]} -{"pcdb_id": 4084, "brand_name": "Glow-worm", "model_name": "Ultimate 40BF", "model_qualifier": "", "winter_efficiency_pct": 73.0, "summer_efficiency_pct": 62.9, "comparative_hot_water_efficiency_pct": 46.0, "output_kw_max": 11.72, "final_year_of_manufacture": 2002, "raw": ["004084", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Ultimate 40BF", "", "41 319 52", "1993", "2002", "1", "2", "1", "1", "0", "", "", "1", "2", "1", "8.79", "11.72", "", "", "73.0", "62.9", "", "46.0", "", "2", "", "", "101", "2", "1", "1", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.1", "78.1", "", "", "", "", "78.3"]} -{"pcdb_id": 4085, "brand_name": "Glow-worm", "model_name": "Ultimate 50BF", "model_qualifier": "", "winter_efficiency_pct": 74.0, "summer_efficiency_pct": 63.9, "comparative_hot_water_efficiency_pct": 46.6, "output_kw_max": 14.65, "final_year_of_manufacture": 2002, "raw": ["004085", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Ultimate 50BF", "", "41 319 53", "1993", "2002", "1", "2", "1", "1", "0", "", "", "1", "2", "1", "11.72", "14.65", "", "", "74.0", "63.9", "", "46.6", "", "2", "", "", "101", "2", "1", "1", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.6", "79.5", "", "", "", "", "79.5"]} -{"pcdb_id": 4086, "brand_name": "Glow-worm", "model_name": "Ultimate 60BF", "model_qualifier": "", "winter_efficiency_pct": 76.5, "summer_efficiency_pct": 66.4, "comparative_hot_water_efficiency_pct": 48.5, "output_kw_max": 17.58, "final_year_of_manufacture": 2003, "raw": ["004086", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Ultimate 60BF", "", "41 319 54", "1993", "2003", "1", "2", "1", "1", "0", "", "", "1", "2", "1", "14.65", "17.58", "", "", "76.5", "66.4", "", "48.5", "", "2", "", "", "101", "2", "1", "1", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.7", "81.5", "", "", "", "", "81.8"]} -{"pcdb_id": 4092, "brand_name": "Glow-worm", "model_name": "Swiftflow 75", "model_qualifier": "Honeywell valve", "winter_efficiency_pct": 72.3, "summer_efficiency_pct": 62.2, "comparative_hot_water_efficiency_pct": 43.7, "output_kw_max": 16.1, "final_year_of_manufacture": 1999, "raw": ["004092", "000207", "0", "2006/Jan/17 12:55", "Hepworth Heating", "Glow-worm", "Swiftflow 75", "Honeywell valve", "47 -313 -14", "1994", "1999", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "16.1", "16.1", "", "", "72.3", "62.2", "", "43.7", "", "2", "", "", "104", "2", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "79.0", "76.0", "", "", "", "", "76.5"]} -{"pcdb_id": 4093, "brand_name": "Glow-worm", "model_name": "Swiftflow 80", "model_qualifier": "Honeywell valve", "winter_efficiency_pct": 74.0, "summer_efficiency_pct": 63.9, "comparative_hot_water_efficiency_pct": 45.0, "output_kw_max": 17.6, "final_year_of_manufacture": 1999, "raw": ["004093", "000207", "0", "2006/Jan/17 12:55", "Hepworth Heating", "Glow-worm", "Swiftflow 80", "Honeywell valve", "47 -313 -10", "1992", "1999", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "17.6", "17.6", "", "", "74.0", "63.9", "", "45.0", "", "2", "", "", "104", "2", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "79.9", "78.6", "", "", "", "", "78.8"]} -{"pcdb_id": 4094, "brand_name": "Glow-worm", "model_name": "Swiftflow 100", "model_qualifier": "Honeywell valve", "winter_efficiency_pct": 71.6, "summer_efficiency_pct": 61.5, "comparative_hot_water_efficiency_pct": 43.2, "output_kw_max": 17.6, "final_year_of_manufacture": 1999, "raw": ["004094", "000207", "0", "2006/Jan/17 12:55", "Hepworth Heating", "Glow-worm", "Swiftflow 100", "Honeywell valve", "47 -313 -08", "1992", "1999", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "17.6", "17.6", "", "", "71.6", "61.5", "", "43.2", "", "2", "", "", "104", "2", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "77.9", "75.6", "", "", "", "", "76.0"]} -{"pcdb_id": 4095, "brand_name": "Glow-worm", "model_name": "Swiftflow 75", "model_qualifier": "SIT valve", "winter_efficiency_pct": 72.3, "summer_efficiency_pct": 62.2, "comparative_hot_water_efficiency_pct": 43.7, "output_kw_max": 16.1, "final_year_of_manufacture": 1999, "raw": ["004095", "000207", "0", "2006/Jan/17 12:55", "Hepworth Heating", "Glow-worm", "Swiftflow 75", "SIT valve", "47 -313 -15", "1994", "1999", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "16.1", "16.1", "", "", "72.3", "62.2", "", "43.7", "", "2", "", "", "104", "2", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "79.0", "76.0", "", "", "", "", "76.5"]} -{"pcdb_id": 4096, "brand_name": "Glow-worm", "model_name": "Swiftflow 80", "model_qualifier": "SIT valve", "winter_efficiency_pct": 74.0, "summer_efficiency_pct": 63.9, "comparative_hot_water_efficiency_pct": 45.0, "output_kw_max": 17.6, "final_year_of_manufacture": 1999, "raw": ["004096", "000207", "0", "2006/Jan/17 12:55", "Hepworth Heating", "Glow-worm", "Swiftflow 80", "SIT valve", "47 -313 -09", "1992", "1999", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "17.6", "17.6", "", "", "74.0", "63.9", "", "45.0", "", "2", "", "", "104", "2", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "79.9", "78.6", "", "", "", "", "78.8"]} -{"pcdb_id": 4097, "brand_name": "Glow-worm", "model_name": "Swiftflow 100", "model_qualifier": "SIT valve", "winter_efficiency_pct": 71.6, "summer_efficiency_pct": 61.5, "comparative_hot_water_efficiency_pct": 43.2, "output_kw_max": 17.6, "final_year_of_manufacture": 1999, "raw": ["004097", "000207", "0", "2006/Jan/17 12:55", "Hepworth Heating", "Glow-worm", "Swiftflow 100", "SIT valve", "47 -313 -07", "1992", "1999", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "17.6", "17.6", "", "", "71.6", "61.5", "", "43.2", "", "2", "", "", "104", "2", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "77.9", "75.6", "", "", "", "", "76.0"]} -{"pcdb_id": 4098, "brand_name": "GAH Heating Products", "model_name": "E50/80", "model_qualifier": "Select", "winter_efficiency_pct": 81.8, "summer_efficiency_pct": 70.1, "comparative_hot_water_efficiency_pct": 51.2, "output_kw_max": 23.4, "final_year_of_manufacture": 2002, "raw": ["004098", "000051", "0", "2012/Mar/27 10:12", "GAH Heating Products", "GAH Heating Products", "E50/80", "Select", "BWE50/80", "1994", "2002", "4", "2", "2", "1", "0", "", "", "1", "2", "2", "14.7", "23.4", "", "", "81.8", "70.1", "", "51.2", "", "2", "", "", "201", "1", "1", "22", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "83.3", "80.4", "", "", "", "", "80.9"]} -{"pcdb_id": 4099, "brand_name": "GAH Heating Products", "model_name": "I40/50", "model_qualifier": "Select", "winter_efficiency_pct": 82.7, "summer_efficiency_pct": 71.0, "comparative_hot_water_efficiency_pct": 51.9, "output_kw_max": 14.7, "final_year_of_manufacture": 2002, "raw": ["004099", "000051", "0", "2012/Mar/27 10:12", "GAH Heating Products", "GAH Heating Products", "I40/50", "Select", "BWI40/50", "1996", "2002", "4", "2", "1", "1", "0", "", "", "1", "2", "2", "11.7", "14.7", "", "", "82.7", "71.0", "", "51.9", "", "2", "", "", "201", "1", "1", "22", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "83.3", "82.2", "", "", "", "", "82.4"]} -{"pcdb_id": 4100, "brand_name": "GAH Heating Products", "model_name": "I50/80", "model_qualifier": "Select", "winter_efficiency_pct": 83.3, "summer_efficiency_pct": 71.6, "comparative_hot_water_efficiency_pct": 52.3, "output_kw_max": 23.4, "final_year_of_manufacture": 2002, "raw": ["004100", "000051", "0", "2012/Mar/27 10:12", "GAH Heating Products", "GAH Heating Products", "I50/80", "Select", "BWI50/80", "1994", "2002", "4", "2", "1", "1", "0", "", "", "1", "2", "2", "14.7", "23.4", "", "", "83.3", "71.6", "", "52.3", "", "2", "", "", "201", "1", "1", "22", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "84.5", "82.2", "", "", "", "", "82.6"]} -{"pcdb_id": 4101, "brand_name": "GAH Heating Products", "model_name": "40/60", "model_qualifier": "Option", "winter_efficiency_pct": 82.9, "summer_efficiency_pct": 71.2, "comparative_hot_water_efficiency_pct": 52.0, "output_kw_max": 18.2, "final_year_of_manufacture": 2002, "raw": ["004101", "000051", "0", "2012/Mar/27 10:12", "GAH Heating Products", "GAH Heating Products", "40/60", "Option", "BF040/60", "1995", "2002", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "11.7", "18.2", "", "", "82.9", "71.2", "", "52.0", "", "2", "", "", "201", "1", "1", "22", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "83.5", "82.4", "", "", "", "", "82.6"]} -{"pcdb_id": 4102, "brand_name": "HEB Boilers", "model_name": "60/80", "model_qualifier": "Option", "winter_efficiency_pct": 81.9, "summer_efficiency_pct": 70.2, "comparative_hot_water_efficiency_pct": 51.3, "output_kw_max": 23.4, "final_year_of_manufacture": 2002, "raw": ["004102", "000051", "0", "2012/Mar/27 10:12", "HEB Boilers", "HEB Boilers", "60/80", "Option", "BF060/80", "1995", "2002", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "18.2", "23.4", "", "", "81.9", "70.2", "", "51.3", "", "2", "", "", "201", "1", "1", "22", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.7", "82.1", "", "", "", "", "82.0"]} -{"pcdb_id": 4103, "brand_name": "GAH Heating Products", "model_name": "80/95", "model_qualifier": "Option", "winter_efficiency_pct": 81.8, "summer_efficiency_pct": 70.1, "comparative_hot_water_efficiency_pct": 51.2, "output_kw_max": 27.8, "final_year_of_manufacture": 2002, "raw": ["004103", "000051", "0", "2012/Mar/27 10:12", "GAH Heating Products", "GAH Heating Products", "80/95", "Option", "BFSO80/95", "1995", "2002", "4", "1", "1", "1", "0", "", "", "1", "2", "1", "23.4", "27.8", "", "", "81.8", "70.1", "", "51.2", "", "2", "", "", "201", "1", "1", "22", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.7", "82.0", "", "", "", "", "81.9"]} -{"pcdb_id": 4104, "brand_name": "GAH Heating Products", "model_name": "100/150", "model_qualifier": "Option", "winter_efficiency_pct": 82.8, "summer_efficiency_pct": 71.1, "comparative_hot_water_efficiency_pct": 52.0, "output_kw_max": 43.9, "final_year_of_manufacture": 2002, "raw": ["004104", "000051", "0", "2012/Mar/27 10:12", "GAH Heating Products", "GAH Heating Products", "100/150", "Option", "BF0100/150", "1995", "2002", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "29.3", "43.9", "", "", "82.8", "71.1", "", "52.0", "", "2", "", "", "201", "1", "1", "22", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.8", "82.8", "", "", "", "", "82.8"]} -{"pcdb_id": 4105, "brand_name": "GAH Heating Products", "model_name": "40/60", "model_qualifier": "Select", "winter_efficiency_pct": 82.9, "summer_efficiency_pct": 71.2, "comparative_hot_water_efficiency_pct": 52.0, "output_kw_max": 18.2, "final_year_of_manufacture": 2002, "raw": ["004105", "000051", "0", "2012/Mar/27 10:12", "GAH Heating Products", "GAH Heating Products", "40/60", "Select", "BFS40/60", "1993", "2002", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "11.7", "18.2", "", "", "82.9", "71.2", "", "52.0", "", "2", "", "", "201", "1", "1", "22", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "83.5", "82.4", "", "", "", "", "82.6"]} -{"pcdb_id": 4106, "brand_name": "GAH Heating Products", "model_name": "60/80", "model_qualifier": "Select", "winter_efficiency_pct": 82.9, "summer_efficiency_pct": 71.2, "comparative_hot_water_efficiency_pct": 52.0, "output_kw_max": 18.2, "final_year_of_manufacture": 2002, "raw": ["004106", "000051", "0", "2012/Mar/27 10:12", "GAH Heating Products", "GAH Heating Products", "60/80", "Select", "BFS60/80", "1993", "2002", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "11.7", "18.2", "", "", "82.9", "71.2", "", "52.0", "", "2", "", "", "201", "1", "1", "22", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "83.5", "82.4", "", "", "", "", "82.6"]} -{"pcdb_id": 4107, "brand_name": "GAH Heating Products", "model_name": "80/95", "model_qualifier": "Select", "winter_efficiency_pct": 81.8, "summer_efficiency_pct": 70.1, "comparative_hot_water_efficiency_pct": 51.2, "output_kw_max": 27.8, "final_year_of_manufacture": 2002, "raw": ["004107", "000051", "0", "2012/Mar/27 10:12", "GAH Heating Products", "GAH Heating Products", "80/95", "Select", "BFS80/95", "1993", "2002", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "23.4", "27.8", "", "", "81.8", "70.1", "", "51.2", "", "2", "", "", "201", "1", "1", "22", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.7", "82.0", "", "", "", "", "81.9"]} -{"pcdb_id": 4108, "brand_name": "GAH Heating Products", "model_name": "100/150", "model_qualifier": "Select", "winter_efficiency_pct": 82.8, "summer_efficiency_pct": 71.1, "comparative_hot_water_efficiency_pct": 52.0, "output_kw_max": 43.9, "final_year_of_manufacture": 2002, "raw": ["004108", "000051", "0", "2012/Mar/27 10:12", "GAH Heating Products", "GAH Heating Products", "100/150", "Select", "BFS100/150", "1993", "2002", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "29.3", "43.9", "", "", "82.8", "71.1", "", "52.0", "", "2", "", "", "201", "1", "1", "22", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.8", "82.8", "", "", "", "", "82.8"]} -{"pcdb_id": 4109, "brand_name": "GAH Heating Products", "model_name": "140/190", "model_qualifier": "Select", "winter_efficiency_pct": 83.3, "summer_efficiency_pct": 71.6, "comparative_hot_water_efficiency_pct": 52.3, "output_kw_max": 55.7, "final_year_of_manufacture": 2002, "raw": ["004109", "000051", "0", "2012/Mar/27 10:12", "GAH Heating Products", "GAH Heating Products", "140/190", "Select", "BFS140/190", "1993", "2002", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "41", "55.7", "", "", "83.3", "71.6", "", "52.3", "", "2", "", "", "201", "1", "1", "38", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "84.3", "82.4", "", "", "", "", "82.7"]} -{"pcdb_id": 4110, "brand_name": "GAH Heating Products", "model_name": "190/240", "model_qualifier": "Select", "winter_efficiency_pct": 82.0, "summer_efficiency_pct": 70.3, "comparative_hot_water_efficiency_pct": 51.4, "output_kw_max": null, "final_year_of_manufacture": 2002, "raw": ["004110", "000051", "0", "2012/Mar/27 10:12", "GAH Heating Products", "GAH Heating Products", "190/240", "Select", "BFS190/240", "1998", "2002", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "55.7", ">70kW", "", "", "82.0", "70.3", "", "51.4", "", "2", "", "", "201", "1", "1", "40", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.4", "81.7", "", "", "", "", "81.8"]} -{"pcdb_id": 4111, "brand_name": "GAH Heating Products", "model_name": "E40/50", "model_qualifier": "Select", "winter_efficiency_pct": 82.7, "summer_efficiency_pct": 71.0, "comparative_hot_water_efficiency_pct": 51.9, "output_kw_max": 14.7, "final_year_of_manufacture": 2002, "raw": ["004111", "000051", "0", "2012/Mar/27 10:12", "GAH Heating Products", "GAH Heating Products", "E40/50", "Select", "BWE40/50", "1996", "2002", "4", "2", "2", "1", "0", "", "", "1", "2", "2", "11.7", "14.7", "", "", "82.7", "71.0", "", "51.9", "", "2", "", "", "201", "1", "1", "22", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "83.3", "82.2", "", "", "", "", "82.4"]} -{"pcdb_id": 4112, "brand_name": "Saunier Duval", "model_name": "Xeon 30ff/LP", "model_qualifier": "", "winter_efficiency_pct": 78.9, "summer_efficiency_pct": 68.8, "comparative_hot_water_efficiency_pct": 50.3, "output_kw_max": 8.79, "final_year_of_manufacture": 2003, "raw": ["004112", "000206", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Saunier Duval", "Xeon 30ff/LP", "", "", "1999", "2003", "2", "2", "1", "1", "0", "", "", "1", "2", "2", "8.79", "8.79", "", "", "78.9", "68.8", "", "50.3", "", "2", "0", "", "101", "1", "1", "56", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "80.0", "81.0", "", "", "", "", "80.9"]} -{"pcdb_id": 4113, "brand_name": "Saunier Duval", "model_name": "Xeon 40ff/LP", "model_qualifier": "", "winter_efficiency_pct": 78.9, "summer_efficiency_pct": 68.8, "comparative_hot_water_efficiency_pct": 50.3, "output_kw_max": 11.72, "final_year_of_manufacture": 2003, "raw": ["004113", "000206", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Saunier Duval", "Xeon 40ff/LP", "", "", "1999", "2003", "2", "2", "1", "1", "0", "", "", "1", "2", "2", "11.72", "11.72", "", "", "78.9", "68.8", "", "50.3", "", "2", "0", "", "101", "1", "1", "56", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "80.8", "80.3", "", "", "", "", "80.4"]} -{"pcdb_id": 4114, "brand_name": "Saunier Duval", "model_name": "Xeon 60ff/LP", "model_qualifier": "", "winter_efficiency_pct": 78.4, "summer_efficiency_pct": 68.3, "comparative_hot_water_efficiency_pct": 49.9, "output_kw_max": 17.59, "final_year_of_manufacture": 2003, "raw": ["004114", "000206", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Saunier Duval", "Xeon 60ff/LP", "", "", "1999", "2003", "2", "2", "1", "1", "0", "", "", "1", "2", "2", "17.59", "17.59", "", "", "78.4", "68.3", "", "49.9", "", "2", "0", "", "101", "1", "1", "71", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "80.4", "79.6", "", "", "", "", "79.7"]} -{"pcdb_id": 4115, "brand_name": "Saunier Duval", "model_name": "Xeon 80ff/LP", "model_qualifier": "", "winter_efficiency_pct": 80.7, "summer_efficiency_pct": 70.6, "comparative_hot_water_efficiency_pct": 51.6, "output_kw_max": 21.98, "final_year_of_manufacture": null, "raw": ["004115", "000206", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Saunier Duval", "Xeon 80ff/LP", "", "", "1999", "current", "2", "2", "1", "1", "0", "", "", "1", "2", "2", "21.98", "21.98", "", "", "80.7", "70.6", "", "51.6", "", "2", "0", "", "101", "1", "1", "71", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.2", "82.4", "", "", "", "", "82.4"]} -{"pcdb_id": 4116, "brand_name": "Saunier Duval", "model_name": "50ff/LP", "model_qualifier": "", "winter_efficiency_pct": 81.0, "summer_efficiency_pct": 70.9, "comparative_hot_water_efficiency_pct": 51.8, "output_kw_max": 14.65, "final_year_of_manufacture": null, "raw": ["004116", "000206", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Saunier Duval", "50ff/LP", "", "", "1999", "current", "2", "2", "1", "1", "0", "", "", "1", "2", "2", "14.65", "14.65", "", "", "81.0", "70.9", "", "51.8", "", "2", "0", "", "101", "1", "1", "56", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.4", "82.7", "", "", "", "", "82.7"]} -{"pcdb_id": 4118, "brand_name": "Eco Hometec (UK)", "model_name": "EC38S", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 56.0, "output_kw_max": 46.0, "final_year_of_manufacture": 2006, "raw": ["004118", "000014", "0", "2006/Feb/22 12:39", "Eco Hometec (UK)", "Eco Hometec (UK)", "EC38S", "", "", "1995", "2006", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "46", "46", "", "", "88.3", "79.7", "", "56.0", "", "2", "", "", "104", "1", "2", "60", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "97.5", "", "", "", "", "95.7"]} -{"pcdb_id": 4122, "brand_name": "Eco Hometec (UK)", "model_name": "EC38H", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 38.0, "final_year_of_manufacture": null, "raw": ["004122", "000014", "0", "2012/Mar/27 10:12", "Eco Hometec (UK)", "Eco Hometec (UK)", "EC38H", "", "", "1995", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "38", "38", "", "", "88.3", "79.3", "", "57.9", "", "2", "", "", "102", "1", "2", "60", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "97.5", "", "", "", "", "95.7"]} -{"pcdb_id": 4124, "brand_name": "Eco Hometec (UK)", "model_name": "EC31S", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 56.2, "output_kw_max": 36.0, "final_year_of_manufacture": null, "raw": ["004124", "000014", "0", "2006/Jan/17 12:31", "Eco Hometec (UK)", "Eco Hometec (UK)", "EC31S", "", "", "1995", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "36", "36", "", "", "88.5", "79.9", "", "56.2", "", "2", "", "", "104", "1", "2", "60", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.1", "98.1", "", "", "", "", "96.2"]} -{"pcdb_id": 4126, "brand_name": "Eco Hometec (UK)", "model_name": "EC31HS", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 31.0, "final_year_of_manufacture": null, "raw": ["004126", "000014", "0", "2012/Mar/27 10:12", "Eco Hometec (UK)", "Eco Hometec (UK)", "EC31HS", "", "", "1995", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "31", "31", "", "", "88.5", "79.5", "", "58.1", "", "2", "", "", "102", "1", "2", "60", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.1", "98.1", "", "", "", "", "96.2"]} -{"pcdb_id": 4128, "brand_name": "Eco Hometec (UK)", "model_name": "EC31H", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 31.0, "final_year_of_manufacture": null, "raw": ["004128", "000014", "0", "2012/Mar/27 10:12", "Eco Hometec (UK)", "Eco Hometec (UK)", "EC31H", "", "", "1995", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "31", "31", "", "", "88.5", "79.5", "", "58.1", "", "2", "", "", "102", "1", "2", "60", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.1", "98.1", "", "", "", "", "96.2"]} -{"pcdb_id": 4130, "brand_name": "Eco Hometec (UK)", "model_name": "EC23S", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 56.2, "output_kw_max": 28.0, "final_year_of_manufacture": null, "raw": ["004130", "000014", "0", "2006/Jan/17 12:31", "Eco Hometec (UK)", "Eco Hometec (UK)", "EC23S", "", "", "1995", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28", "28", "", "", "88.5", "79.9", "", "56.2", "", "2", "", "", "104", "1", "2", "60", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.7", "98.1", "", "", "", "", "96.1"]} -{"pcdb_id": 4132, "brand_name": "Eco Hometec (UK)", "model_name": "EC23HS", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 23.0, "final_year_of_manufacture": null, "raw": ["004132", "000014", "0", "2012/Mar/27 10:12", "Eco Hometec (UK)", "Eco Hometec (UK)", "EC23HS", "", "", "1995", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "23", "23", "", "", "88.5", "79.5", "", "58.0", "", "2", "", "", "102", "1", "2", "60", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.7", "98.1", "", "", "", "", "96.1"]} -{"pcdb_id": 4134, "brand_name": "Eco Hometec (UK)", "model_name": "EC23H", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 23.0, "final_year_of_manufacture": null, "raw": ["004134", "000014", "0", "2012/Mar/27 10:12", "Eco Hometec (UK)", "Eco Hometec (UK)", "EC23H", "", "", "1995", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "23", "23", "", "", "88.5", "79.5", "", "58.0", "", "2", "", "", "102", "1", "2", "60", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.7", "98.1", "", "", "", "", "96.1"]} -{"pcdb_id": 4136, "brand_name": "Eco Hometec (UK)", "model_name": "EC16S", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 55.8, "output_kw_max": 22.0, "final_year_of_manufacture": 2006, "raw": ["004136", "000014", "0", "2006/Feb/22 12:38", "Eco Hometec (UK)", "Eco Hometec (UK)", "EC16S", "", "", "1995", "2006", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "22", "22", "", "", "88.0", "79.4", "", "55.8", "", "2", "", "", "104", "1", "2", "60", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.6", "96.9", "", "", "", "", "95.1"]} -{"pcdb_id": 4138, "brand_name": "Eco Hometec (UK)", "model_name": "EC16HS", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 16.0, "final_year_of_manufacture": 2006, "raw": ["004138", "000014", "0", "2012/Mar/27 10:12", "Eco Hometec (UK)", "Eco Hometec (UK)", "EC16HS", "", "", "1995", "2006", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "16", "16", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "60", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.6", "96.9", "", "", "", "", "95.1"]} -{"pcdb_id": 4140, "brand_name": "Eco Hometec (UK)", "model_name": "EC16H", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 16.0, "final_year_of_manufacture": 2006, "raw": ["004140", "000014", "0", "2012/Mar/27 10:12", "Eco Hometec (UK)", "Eco Hometec (UK)", "EC16H", "", "", "1995", "2006", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "16", "16", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "60", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.6", "96.9", "", "", "", "", "95.1"]} -{"pcdb_id": 4141, "brand_name": "Boulter", "model_name": "Bonus", "model_qualifier": "40/65", "winter_efficiency_pct": 86.6, "summer_efficiency_pct": 74.9, "comparative_hot_water_efficiency_pct": 54.7, "output_kw_max": 19.0, "final_year_of_manufacture": 2005, "raw": ["004141", "000041", "0", "2012/Mar/27 10:12", "Boulter Boilers", "Boulter", "Bonus", "40/65", "0001099950", "1999", "2005", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "11.7", "19", "", "", "86.6", "74.9", "", "54.7", "", "2", "", "", "201", "1", "1", "115", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.0", "87.0", "", "", "", "", "87.0"]} -{"pcdb_id": 4142, "brand_name": "Boulter", "model_name": "Bonus", "model_qualifier": "65/95", "winter_efficiency_pct": 84.6, "summer_efficiency_pct": 72.9, "comparative_hot_water_efficiency_pct": 53.2, "output_kw_max": 27.8, "final_year_of_manufacture": 2001, "raw": ["004142", "000041", "0", "2012/Mar/27 10:12", "Boulter Boilers", "Boulter", "Bonus", "65/95", "", "1999", "2001", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "19", "27.8", "", "", "84.6", "72.9", "", "53.2", "", "2", "", "", "201", "1", "1", "115", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "83.9", "85.3", "", "", "", "", "85.0"]} -{"pcdb_id": 4143, "brand_name": "Boulter", "model_name": "Camray 5", "model_qualifier": "40/65", "winter_efficiency_pct": 86.6, "summer_efficiency_pct": 74.9, "comparative_hot_water_efficiency_pct": 54.7, "output_kw_max": 19.0, "final_year_of_manufacture": null, "raw": ["004143", "000041", "0", "2012/Mar/27 10:12", "Boulter Boilers", "Boulter", "Camray 5", "40/65", "0001099837", "1998", "current", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "11.7", "19", "", "", "86.6", "74.9", "", "54.7", "", "2", "", "", "201", "1", "1", "115", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.0", "87.0", "", "", "", "", "87.0"]} -{"pcdb_id": 4144, "brand_name": "Boulter", "model_name": "Camray 5 Utility", "model_qualifier": "40/65 Utility", "winter_efficiency_pct": 86.6, "summer_efficiency_pct": 74.9, "comparative_hot_water_efficiency_pct": 54.7, "output_kw_max": 19.0, "final_year_of_manufacture": null, "raw": ["004144", "000041", "0", "2012/Mar/27 10:12", "Boulter Boilers", "Boulter", "Camray 5 Utility", "40/65 Utility", "0001099840", "1998", "current", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "11.7", "19", "", "", "86.6", "74.9", "", "54.7", "", "2", "", "", "201", "1", "1", "115", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.0", "87.0", "", "", "", "", "87.0"]} -{"pcdb_id": 4145, "brand_name": "Boulter", "model_name": "Camray 5 System", "model_qualifier": "40/65 System", "winter_efficiency_pct": 86.6, "summer_efficiency_pct": 74.9, "comparative_hot_water_efficiency_pct": 54.7, "output_kw_max": 19.0, "final_year_of_manufacture": null, "raw": ["004145", "000041", "0", "2012/Mar/27 10:12", "Boulter Boilers", "Boulter", "Camray 5 System", "40/65 System", "0001039943", "1999", "current", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "11.7", "19", "", "", "86.6", "74.9", "", "54.7", "", "2", "", "", "201", "1", "1", "115", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.0", "87.0", "", "", "", "", "87.0"]} -{"pcdb_id": 4146, "brand_name": "Boulter", "model_name": "Camray 5", "model_qualifier": "65/95", "winter_efficiency_pct": 84.6, "summer_efficiency_pct": 72.9, "comparative_hot_water_efficiency_pct": 53.2, "output_kw_max": 27.8, "final_year_of_manufacture": 2001, "raw": ["004146", "000041", "0", "2012/Mar/27 10:12", "Boulter Boilers", "Boulter", "Camray 5", "65/95", "0001099838", "1998", "2001", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "19", "27.8", "", "", "84.6", "72.9", "", "53.2", "", "2", "", "", "201", "1", "1", "115", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "83.9", "85.3", "", "", "", "", "85.0"]} -{"pcdb_id": 4147, "brand_name": "Boulter", "model_name": "Camray 5 Utility", "model_qualifier": "65/95 Utility", "winter_efficiency_pct": 84.6, "summer_efficiency_pct": 72.9, "comparative_hot_water_efficiency_pct": 53.2, "output_kw_max": 27.8, "final_year_of_manufacture": 2001, "raw": ["004147", "000041", "0", "2012/Mar/27 10:12", "Boulter Boilers", "Boulter", "Camray 5 Utility", "65/95 Utility", "0001099841", "1998", "2001", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "19", "27.8", "", "", "84.6", "72.9", "", "53.2", "", "2", "", "", "201", "1", "1", "115", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "83.9", "85.3", "", "", "", "", "85.0"]} -{"pcdb_id": 4148, "brand_name": "Boulter", "model_name": "Camray 5 System", "model_qualifier": "65/95 System", "winter_efficiency_pct": 84.6, "summer_efficiency_pct": 72.9, "comparative_hot_water_efficiency_pct": 53.2, "output_kw_max": 27.8, "final_year_of_manufacture": 2001, "raw": ["004148", "000041", "0", "2012/Mar/27 10:12", "Boulter Boilers", "Boulter", "Camray 5 System", "65/95 System", "0001039944", "1999", "2001", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "19", "27.8", "", "", "84.6", "72.9", "", "53.2", "", "2", "", "", "201", "1", "1", "115", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "83.9", "85.3", "", "", "", "", "85.0"]} -{"pcdb_id": 4149, "brand_name": "Boulter", "model_name": "Camray 5", "model_qualifier": "100/130", "winter_efficiency_pct": 81.2, "summer_efficiency_pct": 69.5, "comparative_hot_water_efficiency_pct": 50.8, "output_kw_max": 38.1, "final_year_of_manufacture": 2000, "raw": ["004149", "000041", "0", "2012/Mar/27 10:12", "Boulter Boilers", "Boulter", "Camray 5", "100/130", "0001099838", "1998", "2000", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "29.3", "38.1", "", "", "81.2", "69.5", "", "50.8", "", "2", "", "", "201", "1", "1", "115", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.8", "80.7", "", "", "", "", "80.9"]} -{"pcdb_id": 4150, "brand_name": "Boulter", "model_name": "Camray 5 Utility", "model_qualifier": "100/130 Utility", "winter_efficiency_pct": 81.2, "summer_efficiency_pct": 69.5, "comparative_hot_water_efficiency_pct": 50.8, "output_kw_max": 38.1, "final_year_of_manufacture": 2000, "raw": ["004150", "000041", "0", "2012/Mar/27 10:12", "Boulter Boilers", "Boulter", "Camray 5 Utility", "100/130 Utility", "0001099842", "1998", "2000", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "29.3", "38.1", "", "", "81.2", "69.5", "", "50.8", "", "2", "", "", "201", "1", "1", "115", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.8", "80.7", "", "", "", "", "80.9"]} -{"pcdb_id": 4151, "brand_name": "Boulter", "model_name": "Camray 5 System", "model_qualifier": "100/130 System", "winter_efficiency_pct": 81.2, "summer_efficiency_pct": 69.5, "comparative_hot_water_efficiency_pct": 50.8, "output_kw_max": 38.1, "final_year_of_manufacture": 2000, "raw": ["004151", "000041", "0", "2012/Mar/27 10:12", "Boulter Boilers", "Boulter", "Camray 5 System", "100/130 System", "0001039945", "1999", "2000", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "29.3", "38.1", "", "", "81.2", "69.5", "", "50.8", "", "2", "", "", "201", "1", "1", "115", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.8", "80.7", "", "", "", "", "80.9"]} -{"pcdb_id": 4152, "brand_name": "Boulter", "model_name": "Classic", "model_qualifier": "50/70", "winter_efficiency_pct": 80.6, "summer_efficiency_pct": 68.9, "comparative_hot_water_efficiency_pct": 50.3, "output_kw_max": 20.5, "final_year_of_manufacture": 2001, "raw": ["004152", "000041", "0", "2012/Mar/27 10:12", "Boulter Boilers", "Boulter", "Classic", "50/70", "0001039946", "1999", "2001", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "14.7", "20.5", "", "", "80.6", "68.9", "", "50.3", "", "2", "", "", "201", "1", "1", "115", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.0", "79.2", "", "", "", "", "79.7"]} -{"pcdb_id": 4153, "brand_name": "Boulter", "model_name": "Classic", "model_qualifier": "70/90", "winter_efficiency_pct": 81.4, "summer_efficiency_pct": 69.7, "comparative_hot_water_efficiency_pct": 50.9, "output_kw_max": 26.4, "final_year_of_manufacture": 2001, "raw": ["004153", "000041", "0", "2012/Mar/27 10:12", "Boulter Boilers", "Boulter", "Classic", "70/90", "0001039947", "1999", "2001", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "20.5", "26.4", "", "", "81.4", "69.7", "", "50.9", "", "2", "", "", "201", "1", "1", "115", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.7", "81.1", "", "", "", "", "81.3"]} -{"pcdb_id": 4154, "brand_name": "Boulter", "model_name": "Classic", "model_qualifier": "95/130", "winter_efficiency_pct": 86.6, "summer_efficiency_pct": 74.9, "comparative_hot_water_efficiency_pct": 54.7, "output_kw_max": 38.1, "final_year_of_manufacture": 2005, "raw": ["004154", "000041", "0", "2012/Mar/27 10:12", "Boulter Boilers", "Boulter", "Classic", "95/130", "0001039948", "1999", "2005", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "27.8", "38.1", "", "", "86.6", "74.9", "", "54.7", "", "2", "", "", "201", "1", "1", "145", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.0", "88.9", "", "", "", "", "88.4"]} -{"pcdb_id": 4155, "brand_name": "Boulter", "model_name": "Classic", "model_qualifier": "135/165", "winter_efficiency_pct": 85.2, "summer_efficiency_pct": 73.5, "comparative_hot_water_efficiency_pct": 53.7, "output_kw_max": 48.4, "final_year_of_manufacture": 2005, "raw": ["004155", "000041", "0", "2012/Mar/27 10:12", "Boulter Boilers", "Boulter", "Classic", "135/165", "0001039949", "1999", "2005", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "39.6", "48.4", "", "", "85.2", "73.5", "", "53.7", "", "2", "", "", "201", "1", "1", "145", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "83.4", "87.0", "", "", "", "", "86.3"]} -{"pcdb_id": 4156, "brand_name": "Boulter", "model_name": "Camray 3", "model_qualifier": "135/175", "winter_efficiency_pct": 86.2, "summer_efficiency_pct": 74.5, "comparative_hot_water_efficiency_pct": 54.4, "output_kw_max": 51.0, "final_year_of_manufacture": 2001, "raw": ["004156", "000041", "0", "2012/Mar/27 10:12", "Boulter Boilers", "Boulter", "Camray 3", "135/175", "", "1991", "2001", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "40", "51", "", "", "86.2", "74.5", "", "54.4", "", "2", "", "", "201", "1", "1", "200", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.3", "87.9", "", "", "", "", "87.4"]} -{"pcdb_id": 4157, "brand_name": "Boulter", "model_name": "Camray 5", "model_qualifier": "Combi", "winter_efficiency_pct": 82.7, "summer_efficiency_pct": 74.6, "comparative_hot_water_efficiency_pct": 35.0, "output_kw_max": 27.8, "final_year_of_manufacture": 2001, "raw": ["004157", "000041", "0", "2024/Jan/31 10:17", "Boulter Boilers", "Boulter", "Camray 5", "Combi", "", "1999", "2001", "4", "1", "1", "2", "0", "", "", "1", "2", "2", "27.8", "27.8", "", "", "82.7", "74.6", "", "35.0", "", "2", "", "", "203", "1", "1", "145", "0", "1", "1", "0", "40", "0", "15", "3", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "83.9", "85.3", "", "", "", "", "85.0"]} -{"pcdb_id": 4158, "brand_name": "Boulter", "model_name": "Camray", "model_qualifier": "Combi plus", "winter_efficiency_pct": 79.4, "summer_efficiency_pct": 71.3, "comparative_hot_water_efficiency_pct": 29.8, "output_kw_max": 26.4, "final_year_of_manufacture": 2001, "raw": ["004158", "000041", "0", "2024/Jan/31 10:17", "Boulter Boilers", "Boulter", "Camray", "Combi plus", "", "1997", "2001", "4", "1", "1", "2", "0", "", "", "1", "2", "2", "26.4", "26.4", "", "", "79.4", "71.3", "", "29.8", "", "2", "", "", "203", "1", "1", "145", "0", "1", "1", "0", "71", "0", "15", "3", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "83.0", "79.6", "", "", "", "", "80.3"]} -{"pcdb_id": 4159, "brand_name": "Boulter", "model_name": "Compact", "model_qualifier": "50/70", "winter_efficiency_pct": 82.7, "summer_efficiency_pct": 71.0, "comparative_hot_water_efficiency_pct": 51.9, "output_kw_max": 20.0, "final_year_of_manufacture": 2001, "raw": ["004159", "000041", "0", "2012/Mar/27 10:12", "Boulter Boilers", "Boulter", "Compact", "50/70", "", "1994", "2001", "4", "2", "1", "1", "0", "", "", "1", "2", "2", "15", "20", "", "", "82.7", "71.0", "", "51.9", "", "2", "", "", "201", "1", "1", "125", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.6", "82.8", "", "", "", "", "82.8"]} -{"pcdb_id": 4160, "brand_name": "Boulter", "model_name": "Camray", "model_qualifier": "15/19 External", "winter_efficiency_pct": 81.6, "summer_efficiency_pct": 69.9, "comparative_hot_water_efficiency_pct": 51.0, "output_kw_max": 19.0, "final_year_of_manufacture": 2001, "raw": ["004160", "000041", "0", "2012/Mar/27 10:12", "Boulter Boilers", "Boulter", "Camray", "15/19 External", "", "1997", "2001", "4", "2", "2", "1", "0", "", "", "1", "2", "2", "15", "19", "", "", "81.6", "69.9", "", "51.0", "", "2", "", "", "201", "1", "1", "145", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.3", "81.8", "", "", "", "", "81.7"]} -{"pcdb_id": 4161, "brand_name": "Boulter", "model_name": "Centurion", "model_qualifier": "2.5", "winter_efficiency_pct": 77.5, "summer_efficiency_pct": 67.4, "comparative_hot_water_efficiency_pct": 47.4, "output_kw_max": 22.0, "final_year_of_manufacture": null, "raw": ["004161", "000041", "0", "2008/Aug/18 09:41", "Boulter Boilers", "Boulter", "Centurion", "2.5", "GC 47 130 03", "1997", "obsolete", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "22", "22", "", "", "77.5", "67.4", "", "47.4", "", "2", "", "", "104", "1", "2", "100", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.5", "76.0", "", "", "", "", "77.1"]} -{"pcdb_id": 4162, "brand_name": "Boulter", "model_name": "Centurion", "model_qualifier": "3.5", "winter_efficiency_pct": 77.8, "summer_efficiency_pct": 68.7, "comparative_hot_water_efficiency_pct": 32.3, "output_kw_max": 22.0, "final_year_of_manufacture": null, "raw": ["004162", "000041", "0", "2024/Jan/31 10:17", "Boulter Boilers", "Boulter", "Centurion", "3.5", "GC 47 130 03", "1997", "obsolete", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "22", "22", "", "", "77.8", "68.7", "", "32.3", "", "2", "", "", "106", "1", "2", "100", "0", "1", "1", "0", "40", "0", "15", "2", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.5", "76.0", "", "", "", "", "77.1"]} -{"pcdb_id": 4163, "brand_name": "Maxol", "model_name": "Morocco", "model_qualifier": "20", "winter_efficiency_pct": 72.3, "summer_efficiency_pct": 62.2, "comparative_hot_water_efficiency_pct": 45.5, "output_kw_max": 6.0, "final_year_of_manufacture": null, "raw": ["004163", "000007", "0", "2012/Mar/27 10:12", "Maxol (Burco Dean Appliances)", "Maxol", "Morocco", "20", "Maxol", "1988", "current", "1", "2", "1", "1", "0", "", "", "1", "2", "1", "6.0", "6.0", "", "", "72.3", "62.2", "", "45.5", "", "2", "", "", "101", "2", "1", "10", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "77.9", "77.9", "", "", "", "", "77.9"]} -{"pcdb_id": 4164, "brand_name": "Maxol", "model_name": "Morocco", "model_qualifier": "30", "winter_efficiency_pct": 72.3, "summer_efficiency_pct": 62.2, "comparative_hot_water_efficiency_pct": 45.5, "output_kw_max": 9.03, "final_year_of_manufacture": null, "raw": ["004164", "000007", "0", "2012/Mar/27 10:12", "Maxol (Burco Dean Appliances)", "Maxol", "Morocco", "30", "Maxol", "1988", "current", "1", "2", "1", "1", "0", "", "", "1", "2", "1", "9.03", "9.03", "", "", "72.3", "62.2", "", "45.5", "", "2", "", "", "101", "2", "1", "10", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "78.0", "77.8", "", "", "", "", "77.9"]} -{"pcdb_id": 4165, "brand_name": "Maxol", "model_name": "Morocco", "model_qualifier": "40", "winter_efficiency_pct": 72.3, "summer_efficiency_pct": 62.2, "comparative_hot_water_efficiency_pct": 45.5, "output_kw_max": 11.7, "final_year_of_manufacture": null, "raw": ["004165", "000007", "0", "2012/Mar/27 10:12", "Maxol (Burco Dean Appliances)", "Maxol", "Morocco", "40", "Maxol", "1988", "current", "1", "2", "1", "1", "0", "", "", "1", "2", "1", "11.7", "11.7", "", "", "72.3", "62.2", "", "45.5", "", "2", "", "", "101", "2", "1", "10", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "78.0", "77.8", "", "", "", "", "77.9"]} -{"pcdb_id": 4166, "brand_name": "Maxol", "model_name": "Microsystem", "model_qualifier": "502RF", "winter_efficiency_pct": 81.4, "summer_efficiency_pct": 71.3, "comparative_hot_water_efficiency_pct": 52.1, "output_kw_max": 14.6, "final_year_of_manufacture": null, "raw": ["004166", "000007", "0", "2012/Mar/27 10:12", "Maxol (Burco Dean Appliances)", "Maxol", "Microsystem", "502RF", "Maxol", "1999", "current", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "14.6", "14.6", "", "", "81.4", "71.3", "", "52.1", "", "2", "", "", "101", "1", "1", "120", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "83.0", "83.2", "", "", "", "", "83.1"]} -{"pcdb_id": 4167, "brand_name": "Maxol", "model_name": "Microsystem", "model_qualifier": "402RF", "winter_efficiency_pct": 81.4, "summer_efficiency_pct": 71.3, "comparative_hot_water_efficiency_pct": 52.1, "output_kw_max": 11.7, "final_year_of_manufacture": null, "raw": ["004167", "000007", "0", "2012/Mar/27 10:12", "Maxol (Burco Dean Appliances)", "Maxol", "Microsystem", "402RF", "Maxol", "1999", "current", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "11.7", "11.7", "", "", "81.4", "71.3", "", "52.1", "", "2", "", "", "101", "1", "1", "120", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "83.0", "83.2", "", "", "", "", "83.1"]} -{"pcdb_id": 4168, "brand_name": "Maxol", "model_name": "Microsystem", "model_qualifier": "402MDF", "winter_efficiency_pct": 81.4, "summer_efficiency_pct": 71.3, "comparative_hot_water_efficiency_pct": 52.1, "output_kw_max": 11.7, "final_year_of_manufacture": null, "raw": ["004168", "000007", "0", "2012/Mar/27 10:12", "Maxol (Burco Dean Appliances)", "Maxol", "Microsystem", "402MDF", "Maxol", "1999", "current", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "11.7", "11.7", "", "", "81.4", "71.3", "", "52.1", "", "2", "", "", "101", "1", "1", "120", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "83.0", "83.2", "", "", "", "", "83.1"]} -{"pcdb_id": 4169, "brand_name": "Maxol", "model_name": "Microsystem", "model_qualifier": "502MDF", "winter_efficiency_pct": 81.3, "summer_efficiency_pct": 71.2, "comparative_hot_water_efficiency_pct": 52.0, "output_kw_max": 14.74, "final_year_of_manufacture": null, "raw": ["004169", "000007", "0", "2012/Mar/27 10:12", "Maxol (Burco Dean Appliances)", "Maxol", "Microsystem", "502MDF", "Maxol", "1999", "current", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "14.74", "14.74", "", "", "81.3", "71.2", "", "52.0", "", "2", "", "", "101", "1", "1", "120", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.9", "83.0", "", "", "", "", "83.0"]} -{"pcdb_id": 4170, "brand_name": "Maxol", "model_name": "Microturbo", "model_qualifier": "402MDF", "winter_efficiency_pct": 81.5, "summer_efficiency_pct": 71.4, "comparative_hot_water_efficiency_pct": 52.1, "output_kw_max": 11.7, "final_year_of_manufacture": null, "raw": ["004170", "000007", "0", "2012/Mar/27 10:12", "Maxol (Burco Dean Appliances)", "Maxol", "Microturbo", "402MDF", "Maxol", "1992", "current", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "11.7", "11.7", "", "", "81.5", "71.4", "", "52.1", "", "2", "", "", "101", "1", "1", "55", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.7", "83.4", "", "", "", "", "83.3"]} -{"pcdb_id": 4171, "brand_name": "Maxol", "model_name": "Microturbo", "model_qualifier": "402 RF", "winter_efficiency_pct": 81.5, "summer_efficiency_pct": 71.4, "comparative_hot_water_efficiency_pct": 52.1, "output_kw_max": 11.72, "final_year_of_manufacture": null, "raw": ["004171", "000007", "0", "2012/Mar/27 10:12", "Maxol (Burco Dean Appliances)", "Maxol", "Microturbo", "402 RF", "Maxol", "1992", "current", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "11.72", "11.72", "", "", "81.5", "71.4", "", "52.1", "", "2", "", "", "101", "1", "1", "55", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.7", "83.4", "", "", "", "", "83.3"]} -{"pcdb_id": 4172, "brand_name": "Maxol", "model_name": "Microturbo", "model_qualifier": "502MDF", "winter_efficiency_pct": 81.3, "summer_efficiency_pct": 71.2, "comparative_hot_water_efficiency_pct": 52.0, "output_kw_max": 14.74, "final_year_of_manufacture": null, "raw": ["004172", "000007", "0", "2012/Mar/27 10:12", "Maxol (Burco Dean Appliances)", "Maxol", "Microturbo", "502MDF", "Maxol", "1992", "current", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "14.74", "14.74", "", "", "81.3", "71.2", "", "52.0", "", "2", "", "", "101", "1", "1", "55", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.9", "83.0", "", "", "", "", "83.0"]} -{"pcdb_id": 4173, "brand_name": "Maxol", "model_name": "Microturbo", "model_qualifier": "502RF", "winter_efficiency_pct": 81.3, "summer_efficiency_pct": 71.2, "comparative_hot_water_efficiency_pct": 52.0, "output_kw_max": 14.6, "final_year_of_manufacture": null, "raw": ["004173", "000007", "0", "2012/Mar/27 10:12", "Maxol (Burco Dean Appliances)", "Maxol", "Microturbo", "502RF", "Maxol", "1992", "current", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "14.6", "14.6", "", "", "81.3", "71.2", "", "52.0", "", "2", "", "", "101", "1", "1", "55", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.9", "83.0", "", "", "", "", "83.0"]} -{"pcdb_id": 4181, "brand_name": "Ferroli", "model_name": "100FF", "model_qualifier": "", "winter_efficiency_pct": 71.0, "summer_efficiency_pct": 61.0, "comparative_hot_water_efficiency_pct": 42.8, "output_kw_max": 25.7, "final_year_of_manufacture": 1995, "raw": ["004181", "000097", "0", "2010/Sep/13 17:03", "Ferroli", "Ferroli", "100FF", "", "", "1994", "1995", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "25.7", "25.7", "", "", "71.0", "61.0", "", "42.8", "", "3", "", "", "0", "1", "2", "", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 4182, "brand_name": "Ferroli", "model_name": "77CF", "model_qualifier": "", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 39.2, "output_kw_max": 23.3, "final_year_of_manufacture": 1994, "raw": ["004182", "000097", "0", "2010/Sep/13 17:03", "Ferroli", "Ferroli", "77CF", "", "", "1989", "1994", "1", "2", "1", "2", "0", "", "", "1", "1", "1", "23.3", "23.3", "", "", "66.0", "56.0", "", "39.2", "", "3", "", "", "0", "2", "2", "", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 4183, "brand_name": "Ferroli", "model_name": "77FF(P)", "model_qualifier": "", "winter_efficiency_pct": 71.0, "summer_efficiency_pct": 61.0, "comparative_hot_water_efficiency_pct": 42.8, "output_kw_max": 22.3, "final_year_of_manufacture": 1994, "raw": ["004183", "000097", "0", "2010/Sep/13 17:03", "Ferroli", "Ferroli", "77FF(P)", "", "", "1989", "1994", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "22.3", "22.3", "", "", "71.0", "61.0", "", "42.8", "", "3", "", "", "0", "2", "2", "150", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 4184, "brand_name": "Ferroli", "model_name": "77FF", "model_qualifier": "", "winter_efficiency_pct": 71.0, "summer_efficiency_pct": 61.0, "comparative_hot_water_efficiency_pct": 42.8, "output_kw_max": 22.3, "final_year_of_manufacture": 1994, "raw": ["004184", "000097", "0", "2010/Sep/13 17:03", "Ferroli", "Ferroli", "77FF", "", "", "1989", "1994", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "22.3", "22.3", "", "", "71.0", "61.0", "", "42.8", "", "3", "", "", "0", "2", "2", "150", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 4185, "brand_name": "Ferroli", "model_name": "Optima 1000", "model_qualifier": "", "winter_efficiency_pct": 71.0, "summer_efficiency_pct": 61.0, "comparative_hot_water_efficiency_pct": 42.8, "output_kw_max": 27.9, "final_year_of_manufacture": 1995, "raw": ["004185", "000097", "0", "2010/Sep/13 17:03", "Ferroli", "Ferroli", "Optima 1000", "", "", "1994", "1995", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "27.9", "27.9", "", "", "71.0", "61.0", "", "42.8", "", "3", "", "", "0", "1", "2", "150", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 4186, "brand_name": "Ferroli", "model_name": "Optima 200", "model_qualifier": "", "winter_efficiency_pct": 75.1, "summer_efficiency_pct": 65.0, "comparative_hot_water_efficiency_pct": 45.7, "output_kw_max": 23.3, "final_year_of_manufacture": 1995, "raw": ["004186", "000097", "0", "2006/Jan/17 12:55", "Ferroli", "Ferroli", "Optima 200", "", "", "1994", "1995", "1", "2", "1", "2", "0", "", "", "1", "1", "1", "23.3", "23.3", "", "", "75.1", "65.0", "", "45.7", "", "2", "", "", "104", "2", "2", "", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.5", "79.1", "", "", "", "", "79.6"]} -{"pcdb_id": 4187, "brand_name": "Ferroli", "model_name": "Optima 2000", "model_qualifier": "", "winter_efficiency_pct": 92.0, "summer_efficiency_pct": 74.0, "comparative_hot_water_efficiency_pct": 51.9, "output_kw_max": 24.2, "final_year_of_manufacture": 1995, "raw": ["004187", "000097", "0", "2010/Sep/13 17:03", "Ferroli", "Ferroli", "Optima 2000", "", "", "1994", "1995", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "92.0", "74.0", "", "51.9", "", "3", "", "", "0", "1", "2", "150", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 4188, "brand_name": "Ferroli", "model_name": "Optima 600", "model_qualifier": "", "winter_efficiency_pct": 71.0, "summer_efficiency_pct": 61.0, "comparative_hot_water_efficiency_pct": 42.8, "output_kw_max": 22.3, "final_year_of_manufacture": 1995, "raw": ["004188", "000097", "0", "2010/Sep/13 17:03", "Ferroli", "Ferroli", "Optima 600", "", "", "1994", "1995", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "22.3", "22.3", "", "", "71.0", "61.0", "", "42.8", "", "3", "", "", "0", "2", "2", "150", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 4189, "brand_name": "Ferroli", "model_name": "Optima 700", "model_qualifier": "", "winter_efficiency_pct": 71.0, "summer_efficiency_pct": 61.0, "comparative_hot_water_efficiency_pct": 42.8, "output_kw_max": 22.3, "final_year_of_manufacture": 1995, "raw": ["004189", "000097", "0", "2010/Sep/13 17:03", "Ferroli", "Ferroli", "Optima 700", "", "", "1994", "1995", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "22.3", "22.3", "", "", "71.0", "61.0", "", "42.8", "", "3", "", "", "0", "2", "2", "150", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 4190, "brand_name": "Ferroli", "model_name": "Optima 800", "model_qualifier": "", "winter_efficiency_pct": 71.0, "summer_efficiency_pct": 61.0, "comparative_hot_water_efficiency_pct": 42.8, "output_kw_max": 22.3, "final_year_of_manufacture": 1995, "raw": ["004190", "000097", "0", "2010/Sep/13 17:03", "Ferroli", "Ferroli", "Optima 800", "", "", "1994", "1995", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "22.3", "22.3", "", "", "71.0", "61.0", "", "42.8", "", "3", "", "", "0", "1", "2", "150", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 4191, "brand_name": "Ferroli", "model_name": "Optima 900", "model_qualifier": "", "winter_efficiency_pct": 71.0, "summer_efficiency_pct": 61.0, "comparative_hot_water_efficiency_pct": 42.8, "output_kw_max": 27.9, "final_year_of_manufacture": 1995, "raw": ["004191", "000097", "0", "2010/Sep/13 17:03", "Ferroli", "Ferroli", "Optima 900", "", "", "1994", "1995", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "27.9", "27.9", "", "", "71.0", "61.0", "", "42.8", "", "3", "", "", "0", "2", "2", "150", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 5890, "brand_name": "Ideal", "model_name": "Mexico Super", "model_qualifier": "40FF", "winter_efficiency_pct": 77.6, "summer_efficiency_pct": 67.5, "comparative_hot_water_efficiency_pct": 49.3, "output_kw_max": 11.7, "final_year_of_manufacture": 2001, "raw": ["005890", "000008", "0", "2018/Oct/15 12:00", "Caradon Plumbing", "Ideal", "Mexico Super", "40FF", "G.C.No 41 349 78", "", "2001", "1", "1", "1", "1", "0", "", "", "1", "2", "2", "8.8", "11.7", "", "", "77.6", "67.5", "", "49.3", "", "2", "", "", "101", "1", "1", "100", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.4", "78.9", "", "", "", "", "79.0"]} -{"pcdb_id": 5891, "brand_name": "Ideal", "model_name": "Mexico Super", "model_qualifier": "50FF", "winter_efficiency_pct": 77.6, "summer_efficiency_pct": 67.5, "comparative_hot_water_efficiency_pct": 49.3, "output_kw_max": 14.7, "final_year_of_manufacture": 2001, "raw": ["005891", "000008", "0", "2018/Oct/15 12:00", "Caradon Plumbing", "Ideal", "Mexico Super", "50FF", "G.C.No 41 349 79", "", "2001", "1", "1", "1", "1", "0", "", "", "1", "2", "2", "11.7", "14.7", "", "", "77.6", "67.5", "", "49.3", "", "2", "", "", "101", "1", "1", "100", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.7", "78.7", "", "", "", "", "78.9"]} -{"pcdb_id": 5892, "brand_name": "Ideal", "model_name": "Mexico Super", "model_qualifier": "60FF", "winter_efficiency_pct": 78.0, "summer_efficiency_pct": 67.9, "comparative_hot_water_efficiency_pct": 49.6, "output_kw_max": 17.6, "final_year_of_manufacture": 2001, "raw": ["005892", "000008", "0", "2018/Oct/15 12:00", "Caradon Plumbing", "Ideal", "Mexico Super", "60FF", "G.C.No 41 349 80", "", "2001", "1", "1", "1", "1", "0", "", "", "1", "2", "2", "14.7", "17.6", "", "", "78.0", "67.9", "", "49.6", "", "2", "", "", "101", "1", "1", "100", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "80.1", "79.1", "", "", "", "", "79.3"]} -{"pcdb_id": 5893, "brand_name": "Ideal", "model_name": "Mexico Super", "model_qualifier": "70FF", "winter_efficiency_pct": 78.5, "summer_efficiency_pct": 68.4, "comparative_hot_water_efficiency_pct": 50.0, "output_kw_max": 20.5, "final_year_of_manufacture": 2001, "raw": ["005893", "000008", "0", "2018/Oct/15 12:00", "Caradon Plumbing", "Ideal", "Mexico Super", "70FF", "G.C.No 41 349 81", "", "2001", "1", "1", "1", "1", "0", "", "", "1", "2", "2", "17.6", "20.5", "", "", "78.5", "68.4", "", "50.0", "", "2", "", "", "101", "1", "1", "100", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.8", "80.4", "", "", "", "", "80.3"]} -{"pcdb_id": 5894, "brand_name": "Ideal", "model_name": "Mexico Super", "model_qualifier": "80FF", "winter_efficiency_pct": 80.6, "summer_efficiency_pct": 70.5, "comparative_hot_water_efficiency_pct": 51.5, "output_kw_max": 23.4, "final_year_of_manufacture": 2001, "raw": ["005894", "000008", "0", "2018/Oct/15 12:00", "Caradon Plumbing", "Ideal", "Mexico Super", "80FF", "G.C.No 41 349 82", "", "2001", "1", "1", "1", "1", "0", "", "", "1", "2", "2", "20.5", "23.4", "", "", "80.6", "70.5", "", "51.5", "", "2", "", "", "101", "1", "1", "100", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.9", "82.4", "", "", "", "", "82.3"]} -{"pcdb_id": 5895, "brand_name": "Ideal", "model_name": "Mexico Super", "model_qualifier": "100FF", "winter_efficiency_pct": 78.5, "summer_efficiency_pct": 68.4, "comparative_hot_water_efficiency_pct": 50.0, "output_kw_max": 29.3, "final_year_of_manufacture": 2001, "raw": ["005895", "000008", "0", "2018/Oct/15 12:00", "Caradon Plumbing", "Ideal", "Mexico Super", "100FF", "G.C.No 41 349 83", "", "2001", "1", "1", "1", "1", "0", "", "", "1", "2", "2", "23.4", "29.3", "", "", "78.5", "68.4", "", "50.0", "", "2", "", "", "101", "1", "1", "100", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "80.6", "79.6", "", "", "", "", "79.8"]} -{"pcdb_id": 5896, "brand_name": "Ideal", "model_name": "Mexico Super", "model_qualifier": "125FF", "winter_efficiency_pct": 78.8, "summer_efficiency_pct": 68.7, "comparative_hot_water_efficiency_pct": 50.2, "output_kw_max": 36.6, "final_year_of_manufacture": 2001, "raw": ["005896", "000008", "0", "2018/Oct/15 12:00", "Caradon Plumbing", "Ideal", "Mexico Super", "125FF", "G.C.No 41 349 84", "", "2001", "1", "1", "1", "1", "0", "", "", "1", "2", "2", "29.3", "36.6", "", "", "78.8", "68.7", "", "50.2", "", "2", "", "", "101", "1", "1", "100", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "80.5", "80.3", "", "", "", "", "80.3"]} -{"pcdb_id": 5897, "brand_name": "Ideal", "model_name": "C", "model_qualifier": "95FF", "winter_efficiency_pct": 79.4, "summer_efficiency_pct": 69.3, "comparative_hot_water_efficiency_pct": 48.7, "output_kw_max": 27.9, "final_year_of_manufacture": 2002, "raw": ["005897", "000008", "0", "2018/Oct/15 12:00", "Caradon Plumbing", "Ideal", "C", "95FF", "G.C.No 47 348 06", "", "2002", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "27.9", "27.9", "", "", "79.4", "69.3", "", "48.7", "", "2", "", "", "104", "1", "2", "120", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.0", "79.2", "", "", "", "", "79.7"]} -{"pcdb_id": 5898, "brand_name": "Ideal", "model_name": "C", "model_qualifier": "80FF", "winter_efficiency_pct": 79.3, "summer_efficiency_pct": 69.2, "comparative_hot_water_efficiency_pct": 48.7, "output_kw_max": 23.26, "final_year_of_manufacture": 2002, "raw": ["005898", "000008", "0", "2018/Oct/15 12:00", "Caradon Plumbing", "Ideal", "C", "80FF", "G.C.No 47 348 05", "", "2002", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "23.26", "23.26", "", "", "79.3", "69.2", "", "48.7", "", "2", "", "", "104", "1", "2", "120", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.1", "79.0", "", "", "", "", "79.6"]} -{"pcdb_id": 5899, "brand_name": "Ideal", "model_name": "Maximiser", "model_qualifier": "SE 65", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 55.1, "final_year_of_manufacture": 2002, "raw": ["005899", "000008", "0", "2018/Oct/15 12:00", "Caradon Plumbing", "Ideal", "Maximiser", "SE 65", "152813", "", "2002", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "55.1", "55.1", "", "", "88.1", "79.1", "", "57.8", "", "2", "", "", "102", "1", "2", "180", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "97.1", "", "", "", "", "95.4"]} -{"pcdb_id": 5900, "brand_name": "Ideal", "model_name": "Maximiser", "model_qualifier": "SE 42", "winter_efficiency_pct": 87.8, "summer_efficiency_pct": 78.8, "comparative_hot_water_efficiency_pct": 57.6, "output_kw_max": 40.0, "final_year_of_manufacture": 2002, "raw": ["005900", "000008", "0", "2018/Oct/15 12:00", "Caradon Plumbing", "Ideal", "Maximiser", "SE 42", "152393", "", "2002", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "40", "40", "", "", "87.8", "78.8", "", "57.6", "", "2", "", "", "102", "1", "2", "180", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.7", "96.0", "", "", "", "", "94.6"]} -{"pcdb_id": 5901, "brand_name": "Ideal", "model_name": "Concord", "model_qualifier": "CX40", "winter_efficiency_pct": 72.9, "summer_efficiency_pct": 62.8, "comparative_hot_water_efficiency_pct": 45.9, "output_kw_max": 42.0, "final_year_of_manufacture": null, "raw": ["005901", "000008", "0", "2012/Mar/27 10:12", "Caradon Plumbing", "Ideal", "Concord", "CX40", "P.I.No 87/AP/80", "", "current", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "42", "42", "", "", "72.9", "62.8", "", "45.9", "", "2", "", "", "101", "2", "1", "5", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.2", "77.8", "", "", "", "", "78.1"]} -{"pcdb_id": 5902, "brand_name": "Ideal", "model_name": "Mexico Super", "model_qualifier": "CF3/40", "winter_efficiency_pct": 72.7, "summer_efficiency_pct": 62.6, "comparative_hot_water_efficiency_pct": 45.7, "output_kw_max": 11.7, "final_year_of_manufacture": 2001, "raw": ["005902", "000008", "0", "2018/Oct/15 12:00", "Caradon Plumbing", "Ideal", "Mexico Super", "CF3/40", "G.C.No 41 348 10", "", "2001", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "8.8", "11.7", "", "", "72.7", "62.6", "", "45.7", "", "2", "", "", "101", "2", "1", "5", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "78.8", "77.7", "", "", "", "", "77.9"]} -{"pcdb_id": 5903, "brand_name": "Ideal", "model_name": "Mexico Super", "model_qualifier": "CF3/50", "winter_efficiency_pct": 72.2, "summer_efficiency_pct": 62.1, "comparative_hot_water_efficiency_pct": 45.4, "output_kw_max": 14.7, "final_year_of_manufacture": 2001, "raw": ["005903", "000008", "0", "2018/Oct/15 12:00", "Caradon Plumbing", "Ideal", "Mexico Super", "CF3/50", "G.C.No 41 348 12", "", "2001", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "11.7", "14.7", "", "", "72.2", "62.1", "", "45.4", "", "2", "", "", "101", "2", "1", "5", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.1", "76.5", "", "", "", "", "77.0"]} -{"pcdb_id": 5904, "brand_name": "Ideal", "model_name": "Mexico Super", "model_qualifier": "CF3/60", "winter_efficiency_pct": 72.7, "summer_efficiency_pct": 62.6, "comparative_hot_water_efficiency_pct": 45.8, "output_kw_max": 17.6, "final_year_of_manufacture": 2001, "raw": ["005904", "000008", "0", "2018/Oct/15 12:00", "Caradon Plumbing", "Ideal", "Mexico Super", "CF3/60", "G.C.No 41 348 13", "", "2001", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "14.7", "17.6", "", "", "72.7", "62.6", "", "45.8", "", "2", "", "", "101", "2", "1", "5", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.0", "77.7", "", "", "", "", "77.9"]} -{"pcdb_id": 5905, "brand_name": "Ideal", "model_name": "Mexico Slimline", "model_qualifier": "RS3/50", "winter_efficiency_pct": 73.8, "summer_efficiency_pct": 63.7, "comparative_hot_water_efficiency_pct": 46.5, "output_kw_max": 14.7, "final_year_of_manufacture": 2001, "raw": ["005905", "000008", "0", "2018/Oct/15 12:00", "Caradon Plumbing", "Ideal", "Mexico Slimline", "RS3/50", "G.C.No 41 348 06", "", "2001", "1", "1", "1", "1", "0", "", "", "1", "2", "1", "11.7", "14.7", "", "", "73.8", "63.7", "", "46.5", "", "2", "", "", "101", "2", "1", "5", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.0", "79.8", "", "", "", "", "79.7"]} -{"pcdb_id": 5906, "brand_name": "Ideal", "model_name": "Mexico Super", "model_qualifier": "CF3/100", "winter_efficiency_pct": 72.5, "summer_efficiency_pct": 62.4, "comparative_hot_water_efficiency_pct": 45.6, "output_kw_max": 29.3, "final_year_of_manufacture": 2001, "raw": ["005906", "000008", "0", "2018/Oct/15 12:00", "Caradon Plumbing", "Ideal", "Mexico Super", "CF3/100", "G.C.No 41 348 18", "", "2001", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "23.4", "29.3", "", "", "72.5", "62.4", "", "45.6", "", "2", "", "", "101", "2", "1", "5", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.1", "77.0", "", "", "", "", "77.4"]} -{"pcdb_id": 5907, "brand_name": "Ideal", "model_name": "Mexico Super", "model_qualifier": "CF3/125", "winter_efficiency_pct": 72.7, "summer_efficiency_pct": 62.6, "comparative_hot_water_efficiency_pct": 45.8, "output_kw_max": 36.6, "final_year_of_manufacture": 2001, "raw": ["005907", "000008", "0", "2018/Oct/15 12:00", "Caradon Plumbing", "Ideal", "Mexico Super", "CF3/125", "G.C.No 41 348 20", "", "2001", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "29.3", "36.6", "", "", "72.7", "62.6", "", "45.8", "", "2", "", "", "101", "2", "1", "5", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.6", "77.1", "", "", "", "", "77.6"]} -{"pcdb_id": 5908, "brand_name": "Ideal", "model_name": "Mexico Super", "model_qualifier": "CF3/140", "winter_efficiency_pct": 73.6, "summer_efficiency_pct": 63.5, "comparative_hot_water_efficiency_pct": 46.3, "output_kw_max": 41.0, "final_year_of_manufacture": 2001, "raw": ["005908", "000008", "0", "2018/Oct/15 12:00", "Caradon Plumbing", "Ideal", "Mexico Super", "CF3/140", "G.C.No 41 348 21", "", "2001", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "36.6", "41.0", "", "", "73.6", "63.5", "", "46.3", "", "2", "", "", "101", "2", "1", "5", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.0", "79.3", "", "", "", "", "79.2"]} -{"pcdb_id": 5909, "brand_name": "Ideal", "model_name": "Classic", "model_qualifier": "RS 245P", "winter_efficiency_pct": 74.8, "summer_efficiency_pct": 64.7, "comparative_hot_water_efficiency_pct": 47.3, "output_kw_max": 13.2, "final_year_of_manufacture": 2001, "raw": ["005909", "000008", "0", "2018/Oct/15 12:00", "Caradon Plumbing", "Ideal", "Classic", "RS 245P", "G.C.41 387 14", "", "2001", "2", "2", "1", "1", "0", "", "", "1", "2", "1", "13.2", "13.2", "", "", "74.8", "64.7", "", "47.3", "", "2", "0", "", "101", "2", "1", "5", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.1", "79.8", "", "", "", "", "80.0"]} -{"pcdb_id": 5910, "brand_name": "Ideal", "model_name": "Classic", "model_qualifier": "RS 255P", "winter_efficiency_pct": 73.7, "summer_efficiency_pct": 63.6, "comparative_hot_water_efficiency_pct": 46.5, "output_kw_max": 16.1, "final_year_of_manufacture": 2001, "raw": ["005910", "000008", "0", "2018/Oct/15 12:00", "Caradon Plumbing", "Ideal", "Classic", "RS 255P", "G.C.41 387 15", "", "2001", "2", "2", "1", "1", "0", "", "", "1", "2", "1", "16.1", "16.1", "", "", "73.7", "63.6", "", "46.5", "", "2", "0", "", "101", "2", "1", "5", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.7", "79.0", "", "", "", "", "79.1"]} -{"pcdb_id": 5911, "brand_name": "Ideal", "model_name": "Classic", "model_qualifier": "LX RS245P", "winter_efficiency_pct": 74.8, "summer_efficiency_pct": 64.7, "comparative_hot_water_efficiency_pct": 47.3, "output_kw_max": 13.2, "final_year_of_manufacture": 2001, "raw": ["005911", "000008", "0", "2018/Oct/15 12:00", "Caradon Plumbing", "Ideal", "Classic", "LX RS245P", "G.C.41 387 37", "", "2001", "2", "2", "1", "1", "0", "", "", "1", "2", "1", "13.2", "13.2", "", "", "74.8", "64.7", "", "47.3", "", "2", "0", "", "101", "2", "1", "5", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.1", "79.8", "", "", "", "", "80.0"]} -{"pcdb_id": 5912, "brand_name": "Ideal", "model_name": "Classic", "model_qualifier": "LX RS255P", "winter_efficiency_pct": 73.7, "summer_efficiency_pct": 63.6, "comparative_hot_water_efficiency_pct": 46.5, "output_kw_max": 16.1, "final_year_of_manufacture": 2001, "raw": ["005912", "000008", "0", "2018/Oct/15 12:00", "Caradon Plumbing", "Ideal", "Classic", "LX RS255P", "G.C.41 387 38", "", "2001", "2", "2", "1", "1", "0", "", "", "1", "2", "1", "16.1", "16.1", "", "", "73.7", "63.6", "", "46.5", "", "2", "0", "", "101", "2", "1", "5", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.7", "79.0", "", "", "", "", "79.1"]} -{"pcdb_id": 5913, "brand_name": "Ideal", "model_name": "Classic", "model_qualifier": "FF250P", "winter_efficiency_pct": 82.6, "summer_efficiency_pct": 72.5, "comparative_hot_water_efficiency_pct": 52.9, "output_kw_max": 14.7, "final_year_of_manufacture": 2004, "raw": ["005913", "000008", "0", "2018/Oct/15 12:00", "Caradon Plumbing", "Ideal", "Classic", "FF250P", "G.C.41 387 07", "", "2004", "2", "2", "1", "1", "0", "", "", "1", "2", "2", "14.7", "14.7", "", "", "82.6", "72.5", "", "52.9", "", "2", "0", "", "101", "1", "1", "100", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "84.5", "84.2", "", "", "", "", "84.2"]} -{"pcdb_id": 5914, "brand_name": "Ideal", "model_name": "Classic", "model_qualifier": "FF260P", "winter_efficiency_pct": 79.4, "summer_efficiency_pct": 69.3, "comparative_hot_water_efficiency_pct": 50.7, "output_kw_max": 16.7, "final_year_of_manufacture": 2004, "raw": ["005914", "000008", "0", "2018/Oct/15 12:00", "Caradon Plumbing", "Ideal", "Classic", "FF260P", "G.C.41 387 08", "", "2004", "2", "2", "1", "1", "0", "", "", "1", "2", "2", "16.7", "16.7", "", "", "79.4", "69.3", "", "50.7", "", "2", "0", "", "101", "1", "1", "100", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.0", "81.0", "", "", "", "", "81.0"]} -{"pcdb_id": 5915, "brand_name": "Ideal", "model_name": "Classic", "model_qualifier": "FF275P", "winter_efficiency_pct": 78.3, "summer_efficiency_pct": 68.2, "comparative_hot_water_efficiency_pct": 49.8, "output_kw_max": 21.4, "final_year_of_manufacture": 2004, "raw": ["005915", "000008", "0", "2018/Oct/15 12:00", "Caradon Plumbing", "Ideal", "Classic", "FF275P", "G.C.41 387 09", "", "2004", "2", "2", "1", "1", "0", "", "", "1", "2", "2", "21.4", "21.4", "", "", "78.3", "68.2", "", "49.8", "", "2", "0", "", "101", "1", "1", "100", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.9", "79.9", "", "", "", "", "79.9"]} -{"pcdb_id": 5916, "brand_name": "Ideal", "model_name": "Classic", "model_qualifier": "LX FF250P", "winter_efficiency_pct": 82.6, "summer_efficiency_pct": 72.5, "comparative_hot_water_efficiency_pct": 52.9, "output_kw_max": 14.7, "final_year_of_manufacture": 2004, "raw": ["005916", "000008", "0", "2018/Oct/15 12:00", "Caradon Plumbing", "Ideal", "Classic", "LX FF250P", "G.C.41 387 30", "", "2004", "2", "2", "1", "1", "0", "", "", "1", "2", "2", "14.7", "14.7", "", "", "82.6", "72.5", "", "52.9", "", "2", "0", "", "101", "1", "1", "100", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "84.5", "84.2", "", "", "", "", "84.2"]} -{"pcdb_id": 5917, "brand_name": "Ideal", "model_name": "Classic", "model_qualifier": "LX FF260P", "winter_efficiency_pct": 79.4, "summer_efficiency_pct": 69.3, "comparative_hot_water_efficiency_pct": 50.7, "output_kw_max": 16.7, "final_year_of_manufacture": 2004, "raw": ["005917", "000008", "0", "2018/Oct/15 12:00", "Caradon Plumbing", "Ideal", "Classic", "LX FF260P", "G.C.41 387 31", "", "2004", "2", "2", "1", "1", "0", "", "", "1", "2", "2", "16.7", "16.7", "", "", "79.4", "69.3", "", "50.7", "", "2", "0", "", "101", "1", "1", "100", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.0", "81.0", "", "", "", "", "81.0"]} -{"pcdb_id": 5918, "brand_name": "Ideal", "model_name": "Classic", "model_qualifier": "LX FF275P", "winter_efficiency_pct": 78.3, "summer_efficiency_pct": 68.2, "comparative_hot_water_efficiency_pct": 49.8, "output_kw_max": 21.4, "final_year_of_manufacture": 2004, "raw": ["005918", "000008", "0", "2018/Oct/15 12:00", "Caradon Plumbing", "Ideal", "Classic", "LX FF275P", "G.C.41 387 32", "", "2004", "2", "2", "1", "1", "0", "", "", "1", "2", "2", "21.4", "21.4", "", "", "78.3", "68.2", "", "49.8", "", "2", "0", "", "101", "1", "1", "100", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.9", "79.9", "", "", "", "", "79.9"]} -{"pcdb_id": 5919, "brand_name": "Ideal", "model_name": "Classic", "model_qualifier": "RS 230", "winter_efficiency_pct": 72.1, "summer_efficiency_pct": 62.0, "comparative_hot_water_efficiency_pct": 45.3, "output_kw_max": 8.8, "final_year_of_manufacture": 2001, "raw": ["005919", "000008", "0", "2018/Oct/15 12:00", "Caradon Plumbing", "Ideal", "Classic", "RS 230", "G.C.41 387 10", "", "2001", "1", "2", "1", "1", "0", "", "", "1", "2", "1", "4.4", "8.8", "", "", "72.1", "62.0", "", "45.3", "", "2", "", "", "101", "2", "1", "5", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.7", "75.6", "", "", "", "", "76.4"]} -{"pcdb_id": 5920, "brand_name": "Ideal", "model_name": "Classic", "model_qualifier": "RS 240", "winter_efficiency_pct": 74.1, "summer_efficiency_pct": 64.0, "comparative_hot_water_efficiency_pct": 46.7, "output_kw_max": 11.7, "final_year_of_manufacture": 2001, "raw": ["005920", "000008", "0", "2018/Oct/15 12:00", "Caradon Plumbing", "Ideal", "Classic", "RS 240", "G.C.41 387 11", "", "2001", "1", "2", "1", "1", "0", "", "", "1", "2", "1", "8.8", "11.7", "", "", "74.1", "64.0", "", "46.7", "", "2", "", "", "101", "2", "1", "5", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "80.4", "79.0", "", "", "", "", "79.3"]} -{"pcdb_id": 5921, "brand_name": "Ideal", "model_name": "Classic", "model_qualifier": "RS 250", "winter_efficiency_pct": 73.2, "summer_efficiency_pct": 63.1, "comparative_hot_water_efficiency_pct": 46.1, "output_kw_max": 14.7, "final_year_of_manufacture": 2001, "raw": ["005921", "000008", "0", "2018/Oct/15 12:00", "Caradon Plumbing", "Ideal", "Classic", "RS 250", "G.C.41 387 12", "", "2001", "1", "2", "1", "1", "0", "", "", "1", "2", "1", "11.7", "14.7", "", "", "73.2", "63.1", "", "46.1", "", "2", "", "", "101", "2", "1", "5", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.8", "77.8", "", "", "", "", "78.2"]} -{"pcdb_id": 5922, "brand_name": "Ideal", "model_name": "Classic", "model_qualifier": "RS 260", "winter_efficiency_pct": 73.2, "summer_efficiency_pct": 63.1, "comparative_hot_water_efficiency_pct": 46.1, "output_kw_max": 17.6, "final_year_of_manufacture": 2001, "raw": ["005922", "000008", "0", "2018/Oct/15 12:00", "Caradon Plumbing", "Ideal", "Classic", "RS 260", "G.C.41 387 13", "", "2001", "1", "2", "1", "1", "0", "", "", "1", "2", "1", "14.7", "17.6", "", "", "73.2", "63.1", "", "46.1", "", "2", "", "", "101", "2", "1", "5", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.4", "78.3", "", "", "", "", "78.5"]} -{"pcdb_id": 5923, "brand_name": "Ideal", "model_name": "Classic", "model_qualifier": "LX RS230", "winter_efficiency_pct": 72.1, "summer_efficiency_pct": 62.0, "comparative_hot_water_efficiency_pct": 45.3, "output_kw_max": 8.8, "final_year_of_manufacture": 2001, "raw": ["005923", "000008", "0", "2018/Oct/15 12:00", "Caradon Plumbing", "Ideal", "Classic", "LX RS230", "G.C.41 387 33", "", "2001", "1", "2", "1", "1", "0", "", "", "1", "2", "1", "4.4", "8.8", "", "", "72.1", "62.0", "", "45.3", "", "2", "", "", "101", "2", "1", "5", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.7", "75.6", "", "", "", "", "76.4"]} -{"pcdb_id": 5924, "brand_name": "Ideal", "model_name": "Classic", "model_qualifier": "LX RS240", "winter_efficiency_pct": 74.1, "summer_efficiency_pct": 64.0, "comparative_hot_water_efficiency_pct": 46.7, "output_kw_max": 11.7, "final_year_of_manufacture": 2001, "raw": ["005924", "000008", "0", "2018/Oct/15 12:00", "Caradon Plumbing", "Ideal", "Classic", "LX RS240", "G.C.41 387 34", "", "2001", "1", "2", "1", "1", "0", "", "", "1", "2", "1", "8.8", "11.7", "", "", "74.1", "64.0", "", "46.7", "", "2", "", "", "101", "2", "1", "5", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "80.4", "79.0", "", "", "", "", "79.3"]} -{"pcdb_id": 5925, "brand_name": "Ideal", "model_name": "Classic", "model_qualifier": "LX RS250", "winter_efficiency_pct": 73.2, "summer_efficiency_pct": 63.1, "comparative_hot_water_efficiency_pct": 46.1, "output_kw_max": 14.7, "final_year_of_manufacture": 2001, "raw": ["005925", "000008", "0", "2018/Oct/15 12:00", "Caradon Plumbing", "Ideal", "Classic", "LX RS250", "G.C.41 387 35", "", "2001", "1", "2", "1", "1", "0", "", "", "1", "2", "1", "11.7", "14.7", "", "", "73.2", "63.1", "", "46.1", "", "2", "", "", "101", "2", "1", "5", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.8", "77.8", "", "", "", "", "78.2"]} -{"pcdb_id": 5926, "brand_name": "Ideal", "model_name": "Classic", "model_qualifier": "LX RS260", "winter_efficiency_pct": 73.2, "summer_efficiency_pct": 63.1, "comparative_hot_water_efficiency_pct": 46.1, "output_kw_max": 17.6, "final_year_of_manufacture": 2001, "raw": ["005926", "000008", "0", "2018/Oct/15 12:00", "Caradon Plumbing", "Ideal", "Classic", "LX RS260", "G.C.41 387 36", "", "2001", "1", "2", "1", "1", "0", "", "", "1", "2", "1", "14.7", "17.6", "", "", "73.2", "63.1", "", "46.1", "", "2", "", "", "101", "2", "1", "5", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.4", "78.3", "", "", "", "", "78.5"]} -{"pcdb_id": 5927, "brand_name": "Ideal", "model_name": "Classic", "model_qualifier": "FF230", "winter_efficiency_pct": 78.1, "summer_efficiency_pct": 68.0, "comparative_hot_water_efficiency_pct": 49.7, "output_kw_max": 8.8, "final_year_of_manufacture": 2001, "raw": ["005927", "000008", "0", "2018/Oct/15 12:00", "Caradon Plumbing", "Ideal", "Classic", "FF230", "G.C.41 387 01", "", "2001", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "4.4", "8.8", "", "", "78.1", "68.0", "", "49.7", "", "2", "", "", "101", "1", "1", "100", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.6", "77.8", "", "", "", "", "78.6"]} -{"pcdb_id": 5928, "brand_name": "Ideal", "model_name": "Classic", "model_qualifier": "FF240", "winter_efficiency_pct": 77.1, "summer_efficiency_pct": 67.0, "comparative_hot_water_efficiency_pct": 48.9, "output_kw_max": 11.7, "final_year_of_manufacture": 2001, "raw": ["005928", "000008", "0", "2018/Oct/15 12:00", "Caradon Plumbing", "Ideal", "Classic", "FF240", "G.C.41 387 02", "", "2001", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "8.8", "11.7", "", "", "77.1", "67.0", "", "48.9", "", "2", "", "", "101", "1", "1", "100", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.3", "78.0", "", "", "", "", "78.3"]} -{"pcdb_id": 5929, "brand_name": "Ideal", "model_name": "Classic", "model_qualifier": "FF250", "winter_efficiency_pct": 77.6, "summer_efficiency_pct": 67.5, "comparative_hot_water_efficiency_pct": 49.3, "output_kw_max": 14.7, "final_year_of_manufacture": 2001, "raw": ["005929", "000008", "0", "2018/Oct/15 12:00", "Caradon Plumbing", "Ideal", "Classic", "FF250", "G.C.41 387 03", "", "2001", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "11.7", "14.7", "", "", "77.6", "67.5", "", "49.3", "", "2", "", "", "101", "1", "1", "100", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "80.0", "78.5", "", "", "", "", "78.8"]} -{"pcdb_id": 5930, "brand_name": "Ideal", "model_name": "Classic", "model_qualifier": "FF260", "winter_efficiency_pct": 77.8, "summer_efficiency_pct": 67.7, "comparative_hot_water_efficiency_pct": 49.4, "output_kw_max": 17.6, "final_year_of_manufacture": 2001, "raw": ["005930", "000008", "0", "2018/Oct/15 12:00", "Caradon Plumbing", "Ideal", "Classic", "FF260", "G.C.41 387 04", "", "2001", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "14.7", "17.6", "", "", "77.8", "67.7", "", "49.4", "", "2", "", "", "101", "1", "1", "100", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.8", "78.9", "", "", "", "", "79.1"]} -{"pcdb_id": 5931, "brand_name": "Ideal", "model_name": "Classic", "model_qualifier": "FF270", "winter_efficiency_pct": 78.1, "summer_efficiency_pct": 68.0, "comparative_hot_water_efficiency_pct": 49.7, "output_kw_max": 20.5, "final_year_of_manufacture": 2001, "raw": ["005931", "000008", "0", "2018/Oct/15 12:00", "Caradon Plumbing", "Ideal", "Classic", "FF270", "G.C.41 387 05", "", "2001", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "17.6", "20.5", "", "", "78.1", "68.0", "", "49.7", "", "2", "", "", "101", "1", "1", "100", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.6", "79.7", "", "", "", "", "79.7"]} -{"pcdb_id": 5932, "brand_name": "Ideal", "model_name": "Classic", "model_qualifier": "FF280", "winter_efficiency_pct": 77.0, "summer_efficiency_pct": 66.9, "comparative_hot_water_efficiency_pct": 48.8, "output_kw_max": 23.4, "final_year_of_manufacture": 2001, "raw": ["005932", "000008", "0", "2018/Oct/15 12:00", "Caradon Plumbing", "Ideal", "Classic", "FF280", "G.C.41 387 06", "", "2001", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "20.5", "23.4", "", "", "77.0", "66.9", "", "48.8", "", "2", "", "", "101", "1", "1", "100", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "78.7", "78.5", "", "", "", "", "78.5"]} -{"pcdb_id": 5933, "brand_name": "Ideal", "model_name": "Classic", "model_qualifier": "FF2100", "winter_efficiency_pct": 77.6, "summer_efficiency_pct": 67.5, "comparative_hot_water_efficiency_pct": 49.3, "output_kw_max": 29.3, "final_year_of_manufacture": 2001, "raw": ["005933", "000008", "0", "2018/Oct/15 12:00", "Caradon Plumbing", "Ideal", "Classic", "FF2100", "G.C.41 349 71", "", "2001", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "24.9", "29.3", "", "", "77.6", "67.5", "", "49.3", "", "2", "", "", "101", "1", "1", "100", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.9", "78.6", "", "", "", "", "78.8"]} -{"pcdb_id": 5934, "brand_name": "Ideal", "model_name": "Classic", "model_qualifier": "LX FF230", "winter_efficiency_pct": 78.1, "summer_efficiency_pct": 68.0, "comparative_hot_water_efficiency_pct": 49.7, "output_kw_max": 8.8, "final_year_of_manufacture": 2001, "raw": ["005934", "000008", "0", "2018/Oct/15 12:00", "Caradon Plumbing", "Ideal", "Classic", "LX FF230", "G.C.41 387 24", "", "2001", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "4.4", "8.8", "", "", "78.1", "68.0", "", "49.7", "", "2", "", "", "101", "1", "1", "100", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.6", "77.8", "", "", "", "", "78.6"]} -{"pcdb_id": 5935, "brand_name": "Ideal", "model_name": "Classic", "model_qualifier": "LX FF240", "winter_efficiency_pct": 77.1, "summer_efficiency_pct": 67.0, "comparative_hot_water_efficiency_pct": 48.9, "output_kw_max": 11.7, "final_year_of_manufacture": 2001, "raw": ["005935", "000008", "0", "2018/Oct/15 12:00", "Caradon Plumbing", "Ideal", "Classic", "LX FF240", "G.C.41 387 25", "", "2001", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "8.8", "11.7", "", "", "77.1", "67.0", "", "48.9", "", "2", "", "", "101", "1", "1", "100", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.3", "78.0", "", "", "", "", "78.3"]} -{"pcdb_id": 5936, "brand_name": "Ideal", "model_name": "Classic", "model_qualifier": "LX FF250", "winter_efficiency_pct": 77.6, "summer_efficiency_pct": 67.5, "comparative_hot_water_efficiency_pct": 49.3, "output_kw_max": 14.7, "final_year_of_manufacture": 2001, "raw": ["005936", "000008", "0", "2018/Oct/15 12:00", "Caradon Plumbing", "Ideal", "Classic", "LX FF250", "G.C.41 387 26", "", "2001", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "11.7", "14.7", "", "", "77.6", "67.5", "", "49.3", "", "2", "", "", "101", "1", "1", "100", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "80.0", "78.5", "", "", "", "", "78.8"]} -{"pcdb_id": 5937, "brand_name": "Ideal", "model_name": "Classic", "model_qualifier": "LX FF260", "winter_efficiency_pct": 77.8, "summer_efficiency_pct": 67.7, "comparative_hot_water_efficiency_pct": 49.4, "output_kw_max": 17.6, "final_year_of_manufacture": 2001, "raw": ["005937", "000008", "0", "2018/Oct/15 12:00", "Caradon Plumbing", "Ideal", "Classic", "LX FF260", "G.C.41 387 27", "", "2001", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "14.7", "17.6", "", "", "77.8", "67.7", "", "49.4", "", "2", "", "", "101", "1", "1", "100", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.8", "78.9", "", "", "", "", "79.1"]} -{"pcdb_id": 5938, "brand_name": "Ideal", "model_name": "Classic", "model_qualifier": "LX FF270", "winter_efficiency_pct": 78.1, "summer_efficiency_pct": 68.0, "comparative_hot_water_efficiency_pct": 49.7, "output_kw_max": 20.5, "final_year_of_manufacture": 2001, "raw": ["005938", "000008", "0", "2018/Oct/15 12:00", "Caradon Plumbing", "Ideal", "Classic", "LX FF270", "G.C.41 387 28", "", "2001", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "17.6", "20.5", "", "", "78.1", "68.0", "", "49.7", "", "2", "", "", "101", "1", "1", "100", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.6", "79.7", "", "", "", "", "79.7"]} -{"pcdb_id": 5939, "brand_name": "Ideal", "model_name": "Classic", "model_qualifier": "LX FF280", "winter_efficiency_pct": 77.4, "summer_efficiency_pct": 67.3, "comparative_hot_water_efficiency_pct": 49.2, "output_kw_max": 23.4, "final_year_of_manufacture": 2001, "raw": ["005939", "000008", "0", "2018/Oct/15 12:00", "Caradon Plumbing", "Ideal", "Classic", "LX FF280", "G.C.41 387 29", "", "2001", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "20.5", "23.4", "", "", "77.4", "67.3", "", "49.2", "", "2", "", "", "101", "1", "1", "100", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.6", "78.5", "", "", "", "", "78.7"]} -{"pcdb_id": 5940, "brand_name": "Ideal", "model_name": "Mexico Slimline", "model_qualifier": "RS3/40", "winter_efficiency_pct": 75.5, "summer_efficiency_pct": 65.4, "comparative_hot_water_efficiency_pct": 47.8, "output_kw_max": 11.7, "final_year_of_manufacture": 2001, "raw": ["005940", "000008", "0", "2018/Oct/15 12:00", "Caradon Plumbing", "Ideal", "Mexico Slimline", "RS3/40", "G.C.No 41 348 04", "", "2001", "1", "1", "1", "1", "0", "", "", "1", "2", "1", "8.8", "11.7", "", "", "75.5", "65.4", "", "47.8", "", "2", "", "", "101", "2", "1", "5", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "80.9", "81.3", "", "", "", "", "81.2"]} -{"pcdb_id": 5941, "brand_name": "Ideal", "model_name": "Mexico Slimline", "model_qualifier": "CF3/40", "winter_efficiency_pct": 71.7, "summer_efficiency_pct": 61.6, "comparative_hot_water_efficiency_pct": 45.0, "output_kw_max": 11.7, "final_year_of_manufacture": 2001, "raw": ["005941", "000008", "0", "2018/Oct/15 12:00", "Caradon Plumbing", "Ideal", "Mexico Slimline", "CF3/40", "G.C.No 41 348 01", "", "2001", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "8.8", "11.7", "", "", "71.7", "61.6", "", "45.0", "", "2", "", "", "101", "2", "1", "5", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "78.7", "75.9", "", "", "", "", "76.4"]} -{"pcdb_id": 5942, "brand_name": "Ideal", "model_name": "Mexico Slimline", "model_qualifier": "CF3/50", "winter_efficiency_pct": 72.5, "summer_efficiency_pct": 62.4, "comparative_hot_water_efficiency_pct": 45.6, "output_kw_max": 14.7, "final_year_of_manufacture": 2001, "raw": ["005942", "000008", "0", "2018/Oct/15 12:00", "Caradon Plumbing", "Ideal", "Mexico Slimline", "CF3/50", "G.C.No 41 348 03", "", "2001", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "11.7", "14.7", "", "", "72.5", "62.4", "", "45.6", "", "2", "", "", "101", "2", "1", "5", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "78.6", "77.6", "", "", "", "", "77.8"]} -{"pcdb_id": 5943, "brand_name": "Ideal", "model_name": "Mexico Super", "model_qualifier": "CF3/100P", "winter_efficiency_pct": 74.7, "summer_efficiency_pct": 64.6, "comparative_hot_water_efficiency_pct": 47.2, "output_kw_max": 29.3, "final_year_of_manufacture": 2001, "raw": ["005943", "000008", "0", "2018/Oct/15 12:00", "Caradon Plumbing", "Ideal", "Mexico Super", "CF3/100P", "G.C.No 41 349 24", "", "2001", "2", "1", "1", "1", "0", "", "", "1", "1", "1", "29.3", "29.3", "", "", "74.7", "64.6", "", "47.2", "", "2", "0", "", "101", "2", "1", "5", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.7", "78.8", "", "", "", "", "79.4"]} -{"pcdb_id": 5944, "brand_name": "Ideal", "model_name": "Mexico Super", "model_qualifier": "CF3/125P", "winter_efficiency_pct": 75.4, "summer_efficiency_pct": 65.3, "comparative_hot_water_efficiency_pct": 47.7, "output_kw_max": 35.6, "final_year_of_manufacture": 2001, "raw": ["005944", "000008", "0", "2018/Oct/15 12:00", "Caradon Plumbing", "Ideal", "Mexico Super", "CF3/125P", "G.C.No 41 349 25", "", "2001", "2", "1", "1", "1", "0", "", "", "1", "1", "1", "35.6", "35.6", "", "", "75.4", "65.3", "", "47.7", "", "2", "0", "", "101", "2", "1", "5", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.2", "79.9", "", "", "", "", "80.3"]} -{"pcdb_id": 5945, "brand_name": "Ideal", "model_name": "Mexico Super", "model_qualifier": "CF3/140P", "winter_efficiency_pct": 75.7, "summer_efficiency_pct": 65.6, "comparative_hot_water_efficiency_pct": 47.9, "output_kw_max": 44.3, "final_year_of_manufacture": 2001, "raw": ["005945", "000008", "0", "2018/Oct/15 12:00", "Caradon Plumbing", "Ideal", "Mexico Super", "CF3/140P", "G.C.No 41 349 26", "", "2001", "2", "1", "1", "1", "0", "", "", "1", "1", "1", "44.3", "44.3", "", "", "75.7", "65.6", "", "47.9", "", "2", "0", "", "101", "2", "1", "5", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.7", "79.9", "", "", "", "", "80.4"]} -{"pcdb_id": 5946, "brand_name": "Ideal", "model_name": "Systemiser", "model_qualifier": "SE", "winter_efficiency_pct": 86.8, "summer_efficiency_pct": 77.8, "comparative_hot_water_efficiency_pct": 56.8, "output_kw_max": 24.0, "final_year_of_manufacture": 2001, "raw": ["005946", "000008", "0", "2012/Mar/27 10:12", "Caradon Plumbing", "Ideal", "Systemiser", "SE", "G.C.No 41 349 70", "", "2001", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24.0", "24.0", "", "", "86.8", "77.8", "", "56.8", "", "2", "", "", "102", "1", "2", "126", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "86.5", "94.3", "", "", "", "", "92.8"]} -{"pcdb_id": 5947, "brand_name": "Ideal", "model_name": "Minimser", "model_qualifier": "SE30", "winter_efficiency_pct": 83.9, "summer_efficiency_pct": 76.3, "comparative_hot_water_efficiency_pct": 55.8, "output_kw_max": 8.8, "final_year_of_manufacture": 2001, "raw": ["005947", "000008", "0", "2012/Mar/27 10:12", "Caradon Plumbing", "Ideal", "Minimser", "SE30", "G.C.No 41 349 64", "", "2001", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "", "8.8", "", "", "83.9", "76.3", "", "55.8", "", "2", "", "", "101", "1", "1", "50", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "86.5", "90.6", "", "", "", "", "89.9"]} -{"pcdb_id": 5948, "brand_name": "Ideal", "model_name": "Minimser", "model_qualifier": "SE40", "winter_efficiency_pct": 84.2, "summer_efficiency_pct": 76.6, "comparative_hot_water_efficiency_pct": 56.0, "output_kw_max": 11.7, "final_year_of_manufacture": 2001, "raw": ["005948", "000008", "0", "2012/Mar/27 10:12", "Caradon Plumbing", "Ideal", "Minimser", "SE40", "G.C.No 41 349 65", "", "2001", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "", "11.7", "", "", "84.2", "76.6", "", "56.0", "", "2", "", "", "101", "1", "1", "50", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "87.3", "91.0", "", "", "", "", "90.3"]} -{"pcdb_id": 5949, "brand_name": "Ideal", "model_name": "Minimser", "model_qualifier": "SE50", "winter_efficiency_pct": 84.1, "summer_efficiency_pct": 76.5, "comparative_hot_water_efficiency_pct": 55.8, "output_kw_max": 14.7, "final_year_of_manufacture": 2001, "raw": ["005949", "000008", "0", "2012/Mar/27 10:12", "Caradon Plumbing", "Ideal", "Minimser", "SE50", "G.C.No 41 349 66", "", "2001", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "", "14.7", "", "", "84.1", "76.5", "", "55.8", "", "2", "", "", "101", "1", "1", "50", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "87.0", "90.7", "", "", "", "", "90.0"]} -{"pcdb_id": 5950, "brand_name": "Ideal", "model_name": "Minimser", "model_qualifier": "SE60", "winter_efficiency_pct": 84.0, "summer_efficiency_pct": 76.4, "comparative_hot_water_efficiency_pct": 55.8, "output_kw_max": 17.6, "final_year_of_manufacture": 2001, "raw": ["005950", "000008", "0", "2012/Mar/27 10:12", "Caradon Plumbing", "Ideal", "Minimser", "SE60", "G.C.No 41 349 67", "", "2001", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "", "17.6", "", "", "84.0", "76.4", "", "55.8", "", "2", "", "", "101", "1", "1", "50", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "87.0", "90.6", "", "", "", "", "90.0"]} -{"pcdb_id": 5951, "brand_name": "Ideal", "model_name": "Minimser", "model_qualifier": "SE70", "winter_efficiency_pct": 84.1, "summer_efficiency_pct": 76.5, "comparative_hot_water_efficiency_pct": 55.9, "output_kw_max": 20.5, "final_year_of_manufacture": 2001, "raw": ["005951", "000008", "0", "2012/Mar/27 10:12", "Caradon Plumbing", "Ideal", "Minimser", "SE70", "G.C.No 41 349 68", "", "2001", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "", "20.5", "", "", "84.1", "76.5", "", "55.9", "", "2", "", "", "101", "1", "1", "50", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "87.0", "90.9", "", "", "", "", "90.2"]} -{"pcdb_id": 5952, "brand_name": "Ideal", "model_name": "Minimser", "model_qualifier": "SE80", "winter_efficiency_pct": 84.0, "summer_efficiency_pct": 76.4, "comparative_hot_water_efficiency_pct": 55.8, "output_kw_max": 23.4, "final_year_of_manufacture": 2001, "raw": ["005952", "000008", "0", "2012/Mar/27 10:12", "Caradon Plumbing", "Ideal", "Minimser", "SE80", "G.C.No 41 349 69", "", "2001", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "", "23.4", "", "", "84.0", "76.4", "", "55.8", "", "2", "", "", "101", "1", "1", "50", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "86.9", "90.6", "", "", "", "", "89.9"]} -{"pcdb_id": 5953, "brand_name": "Ideal", "model_name": "Response", "model_qualifier": "80", "winter_efficiency_pct": 80.3, "summer_efficiency_pct": 70.2, "comparative_hot_water_efficiency_pct": 49.4, "output_kw_max": 17.6, "final_year_of_manufacture": 2002, "raw": ["005953", "000008", "0", "2006/Jan/17 12:55", "Caradon Plumbing", "Ideal", "Response", "80", "G.C.No 47 348 02", "", "2002", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "17.6", "17.6", "", "", "80.3", "70.2", "", "49.4", "", "2", "", "", "104", "1", "2", "160", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "80.7", "82.4", "", "", "", "", "82.0"]} -{"pcdb_id": 5954, "brand_name": "Ideal", "model_name": "Response", "model_qualifier": "100", "winter_efficiency_pct": 80.9, "summer_efficiency_pct": 70.8, "comparative_hot_water_efficiency_pct": 49.8, "output_kw_max": 23.4, "final_year_of_manufacture": 2002, "raw": ["005954", "000008", "0", "2006/Jan/17 12:55", "Caradon Plumbing", "Ideal", "Response", "100", "G.C.No 47 348 04", "", "2002", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "23.4", "23.4", "", "", "80.9", "70.8", "", "49.8", "", "2", "", "", "104", "1", "2", "160", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.0", "83.3", "", "", "", "", "82.8"]} -{"pcdb_id": 5955, "brand_name": "Ideal", "model_name": "Response", "model_qualifier": "120", "winter_efficiency_pct": 80.9, "summer_efficiency_pct": 70.8, "comparative_hot_water_efficiency_pct": 49.8, "output_kw_max": 23.4, "final_year_of_manufacture": 2003, "raw": ["005955", "000008", "0", "2006/Jan/17 12:55", "Caradon Plumbing", "Ideal", "Response", "120", "G.C.No 47 348 01", "", "2003", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "23.4", "23.4", "", "", "80.9", "70.8", "", "49.8", "", "2", "", "", "104", "1", "2", "160", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.0", "83.3", "", "", "", "", "82.8"]} -{"pcdb_id": 5956, "brand_name": "Ideal", "model_name": "Response", "model_qualifier": "SE", "winter_efficiency_pct": 86.8, "summer_efficiency_pct": 78.2, "comparative_hot_water_efficiency_pct": 55.0, "output_kw_max": 24.0, "final_year_of_manufacture": 2001, "raw": ["005956", "000008", "0", "2006/Jan/17 12:55", "Caradon Plumbing", "Ideal", "Response", "SE", "G.C.No 47 348 03", "", "2001", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.0", "24.0", "", "", "86.8", "78.2", "", "55.0", "", "2", "", "", "104", "1", "2", "126", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "86.5", "94.3", "", "", "", "", "92.8"]} -{"pcdb_id": 5957, "brand_name": "Ideal", "model_name": "Concord", "model_qualifier": "CXD40", "winter_efficiency_pct": 77.2, "summer_efficiency_pct": 66.5, "comparative_hot_water_efficiency_pct": 48.5, "output_kw_max": 42.0, "final_year_of_manufacture": 2000, "raw": ["005957", "000008", "0", "2012/Mar/27 10:12", "Caradon Plumbing", "Ideal", "Concord", "CXD40", "P.I.No 87/AQ/103", "", "2000", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "42", "42", "", "", "77.2", "66.5", "", "48.5", "", "2", "", "", "102", "1", "2", "10", "1", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "79.2", "77.1", "", "", "", "", "77.5"]} -{"pcdb_id": 5958, "brand_name": "Ideal", "model_name": "Concord", "model_qualifier": "CXD50", "winter_efficiency_pct": 77.2, "summer_efficiency_pct": 66.5, "comparative_hot_water_efficiency_pct": 48.6, "output_kw_max": 50.0, "final_year_of_manufacture": 2000, "raw": ["005958", "000008", "0", "2012/Mar/27 10:12", "Caradon Plumbing", "Ideal", "Concord", "CXD50", "P.I.No 87/AQ/103", "", "2000", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "50", "50", "", "", "77.2", "66.5", "", "48.6", "", "2", "", "", "102", "1", "2", "10", "1", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "79.5", "76.9", "", "", "", "", "77.4"]} -{"pcdb_id": 5959, "brand_name": "Ideal", "model_name": "Concord", "model_qualifier": "CXD60", "winter_efficiency_pct": 78.7, "summer_efficiency_pct": 68.0, "comparative_hot_water_efficiency_pct": 49.7, "output_kw_max": 60.08, "final_year_of_manufacture": 2000, "raw": ["005959", "000008", "0", "2012/Mar/27 10:12", "Caradon Plumbing", "Ideal", "Concord", "CXD60", "P.I.No 87/AQ/103", "", "2000", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "60.08", "60.08", "", "", "78.7", "68.0", "", "49.7", "", "2", "", "", "102", "1", "2", "10", "1", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "80.7", "78.7", "", "", "", "", "79.1"]} -{"pcdb_id": 5964, "brand_name": "Ideal", "model_name": "Concord", "model_qualifier": "CX50", "winter_efficiency_pct": 73.3, "summer_efficiency_pct": 63.2, "comparative_hot_water_efficiency_pct": 46.2, "output_kw_max": 50.0, "final_year_of_manufacture": null, "raw": ["005964", "000008", "0", "2012/Mar/27 10:12", "Caradon Plumbing", "Ideal", "Concord", "CX50", "P.I.No 87/AP/80", "", "current", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "50", "50", "", "", "73.3", "63.2", "", "46.2", "", "2", "", "", "101", "2", "1", "5", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.5", "78.4", "", "", "", "", "78.6"]} -{"pcdb_id": 5965, "brand_name": "Ideal", "model_name": "Concord", "model_qualifier": "CX60", "winter_efficiency_pct": 74.4, "summer_efficiency_pct": 64.3, "comparative_hot_water_efficiency_pct": 47.0, "output_kw_max": 60.08, "final_year_of_manufacture": null, "raw": ["005965", "000008", "0", "2012/Mar/27 10:12", "Caradon Plumbing", "Ideal", "Concord", "CX60", "P.I.No 87/AP/80", "", "current", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "60.08", "60.08", "", "", "74.4", "64.3", "", "47.0", "", "2", "", "", "101", "2", "1", "5", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "80.7", "79.3", "", "", "", "", "79.6"]} -{"pcdb_id": 5977, "brand_name": "Ideal", "model_name": "Concord", "model_qualifier": "CXC48", "winter_efficiency_pct": 84.7, "summer_efficiency_pct": 75.7, "comparative_hot_water_efficiency_pct": 55.3, "output_kw_max": 48.83, "final_year_of_manufacture": null, "raw": ["005977", "000008", "0", "2012/Mar/27 10:12", "Caradon Plumbing", "Ideal", "Concord", "CXC48", "P.I.No 87/AQ/340", "", "current", "1", "1", "1", "1", "0", "", "", "2", "1", "2", "48.83", "48.83", "", "", "84.7", "75.7", "", "55.3", "", "2", "", "", "102", "1", "2", "110", "1", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "84.8", "90.7", "", "", "", "", "89.6"]} -{"pcdb_id": 5978, "brand_name": "Ideal", "model_name": "Concord", "model_qualifier": "CXC70", "winter_efficiency_pct": 84.5, "summer_efficiency_pct": 75.5, "comparative_hot_water_efficiency_pct": 55.2, "output_kw_max": 69.84, "final_year_of_manufacture": null, "raw": ["005978", "000008", "0", "2012/Mar/27 10:12", "Caradon Plumbing", "Ideal", "Concord", "CXC70", "P.I.No 87/AQ/340", "", "current", "1", "1", "1", "1", "0", "", "", "2", "1", "2", "69.84", "69.84", "", "", "84.5", "75.5", "", "55.2", "", "2", "", "", "102", "1", "2", "110", "1", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "85.1", "90.0", "", "", "", "", "89.1"]} -{"pcdb_id": 5981, "brand_name": "Atmos", "model_name": "Multi", "model_qualifier": "24/80 Plus", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 81.3, "comparative_hot_water_efficiency_pct": 50.7, "output_kw_max": 24.0, "final_year_of_manufacture": null, "raw": ["005981", "000141", "0", "2024/Jan/31 10:17", "Daalderop bv Netherlands", "Atmos", "Multi", "24/80 Plus", "CCB24/80+", "1995", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "1", "24", "24", "", "", "88.4", "81.3", "", "50.7", "", "2", "", "", "106", "1", "2", "67", "11", "2", "2", "0", "79.2", "0", "35", "2", "60", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.1", "98.3", "", "", "", "", "96.2"]} -{"pcdb_id": 5983, "brand_name": "Atmos", "model_name": "Multi", "model_qualifier": "24/80", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 81.3, "comparative_hot_water_efficiency_pct": 50.3, "output_kw_max": 24.0, "final_year_of_manufacture": 2010, "raw": ["005983", "000141", "0", "2024/Jan/31 10:17", "Daalderop bv Netherlands", "Atmos", "Multi", "24/80", "CCB24/80", "1993", "2010", "1", "2", "1", "2", "0", "", "", "2", "2", "1", "24", "24", "", "", "88.4", "81.3", "", "50.3", "", "2", "", "", "106", "1", "2", "67", "11", "2", "2", "0", "82.2", "0", "35", "2", "60", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.1", "98.3", "", "", "", "", "96.2"]} -{"pcdb_id": 5984, "brand_name": "Atmos", "model_name": "Multi", "model_qualifier": "32/80", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 81.2, "comparative_hot_water_efficiency_pct": 50.2, "output_kw_max": 32.0, "final_year_of_manufacture": 2010, "raw": ["005984", "000141", "0", "2024/Jan/31 10:17", "Daalderop bv Netherlands", "Atmos", "Multi", "32/80", "CCB32/80", "1997", "2010", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "32", "32", "", "", "88.4", "81.2", "", "50.2", "", "2", "", "", "106", "1", "2", "67", "11", "2", "2", "0", "82.5", "0", "35", "2", "60", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "86.3", "98.4", "", "", "", "", "96.1"]} -{"pcdb_id": 5985, "brand_name": "Atmos", "model_name": "Multi", "model_qualifier": "32/80 Plus", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 81.2, "comparative_hot_water_efficiency_pct": 50.6, "output_kw_max": 32.0, "final_year_of_manufacture": 2010, "raw": ["005985", "000141", "0", "2024/Jan/31 10:17", "Daalderop bv Netherlands", "Atmos", "Multi", "32/80 Plus", "CCB32/80+", "1997", "2010", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "32", "32", "", "", "88.4", "81.2", "", "50.6", "", "2", "", "", "106", "1", "2", "67", "11", "2", "2", "0", "79.5", "0", "35", "2", "60", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "86.3", "98.4", "", "", "", "", "96.1"]} -{"pcdb_id": 5986, "brand_name": "Worcester", "model_name": "25 Si", "model_qualifier": "RSF", "winter_efficiency_pct": 82.0, "summer_efficiency_pct": 71.9, "comparative_hot_water_efficiency_pct": 50.5, "output_kw_max": 25.0, "final_year_of_manufacture": 2001, "raw": ["005986", "000035", "0", "2002/Jun/10 10:51", "Worcester Heat Systems", "Worcester", "25 Si", "RSF", "47 311 50", "2000", "2001", "2", "2", "1", "2", "0", "", "", "1", "2", "2", "25", "25", "", "", "82.0", "71.9", "", "50.5", "", "2", "0", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "86.0", "81.6", "", "", "", "", "82.4"]} -{"pcdb_id": 5987, "brand_name": "Worcester", "model_name": "25 Si", "model_qualifier": "RSF", "winter_efficiency_pct": 78.6, "summer_efficiency_pct": 68.5, "comparative_hot_water_efficiency_pct": 48.2, "output_kw_max": 25.0, "final_year_of_manufacture": 2001, "raw": ["005987", "000035", "0", "2001/Nov/22 08:38", "Worcester Heat Systems", "Worcester", "25 Si", "RSF", "47 311 49", "2000", "2001", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "25", "25", "", "", "78.6", "68.5", "", "48.2", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "83.6", "76.7", "", "", "", "", "78.0"]} -{"pcdb_id": 5988, "brand_name": "Worcester", "model_name": "28 Si", "model_qualifier": "RSF", "winter_efficiency_pct": 82.3, "summer_efficiency_pct": 72.2, "comparative_hot_water_efficiency_pct": 50.8, "output_kw_max": 28.0, "final_year_of_manufacture": 2002, "raw": ["005988", "000035", "0", "2002/Aug/14 10:52", "Worcester Heat Systems", "Worcester", "28 Si", "RSF", "47 311 52", "2000", "2002", "2", "2", "1", "2", "0", "", "", "1", "2", "2", "28", "28", "", "", "82.3", "72.2", "", "50.8", "", "2", "0", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "86.4", "82.3", "", "", "", "", "83.1"]} -{"pcdb_id": 5989, "brand_name": "Worcester", "model_name": "28 Si", "model_qualifier": "RSF", "winter_efficiency_pct": 79.1, "summer_efficiency_pct": 69.0, "comparative_hot_water_efficiency_pct": 48.5, "output_kw_max": 28.0, "final_year_of_manufacture": 2002, "raw": ["005989", "000035", "0", "2002/Aug/14 10:50", "Worcester Heat Systems", "Worcester", "28 Si", "RSF", "47 311 51", "2000", "2002", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "28", "28", "", "", "79.1", "69.0", "", "48.5", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "84.0", "77.7", "", "", "", "", "78.9"]} -{"pcdb_id": 8050, "brand_name": "Vokera", "model_name": "Linea", "model_qualifier": "Linea 24", "winter_efficiency_pct": 81.2, "summer_efficiency_pct": 71.1, "comparative_hot_water_efficiency_pct": 50.0, "output_kw_max": 23.7, "final_year_of_manufacture": null, "raw": ["008050", "000011", "0", "2006/Jan/17 12:31", "Vokera", "Vokera", "Linea", "Linea 24", "4709427", "1998", "current", "2", "2", "1", "2", "0", "", "", "1", "2", "2", "23.7", "23.7", "", "", "81.2", "71.1", "", "50.0", "", "2", "0", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "84.1", "80.8", "", "", "", "", "81.4"]} -{"pcdb_id": 8051, "brand_name": "Vokera", "model_name": "Linea 24", "model_qualifier": "", "winter_efficiency_pct": 78.4, "summer_efficiency_pct": 68.3, "comparative_hot_water_efficiency_pct": 48.1, "output_kw_max": 23.7, "final_year_of_manufacture": 2001, "raw": ["008051", "000011", "0", "2006/Jan/17 12:55", "Vokera", "Vokera", "Linea 24", "", "47-094-27", "1998", "2001", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "23.7", "23.7", "", "", "78.4", "68.3", "", "48.1", "", "2", "", "", "104", "1", "2", "125", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.2", "77.1", "", "", "", "", "78.1"]} -{"pcdb_id": 8052, "brand_name": "Vokera", "model_name": "Linea", "model_qualifier": "Linea 28", "winter_efficiency_pct": 81.5, "summer_efficiency_pct": 71.4, "comparative_hot_water_efficiency_pct": 50.2, "output_kw_max": 28.0, "final_year_of_manufacture": null, "raw": ["008052", "000011", "0", "2006/Jan/17 12:31", "Vokera", "Vokera", "Linea", "Linea 28", "4709428", "1998", "current", "2", "2", "1", "2", "0", "", "", "1", "2", "2", "28", "28", "", "", "81.5", "71.4", "", "50.2", "", "2", "0", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "84.5", "80.9", "", "", "", "", "81.5"]} -{"pcdb_id": 8053, "brand_name": "Vokera", "model_name": "Linea 28", "model_qualifier": "", "winter_efficiency_pct": 78.5, "summer_efficiency_pct": 68.4, "comparative_hot_water_efficiency_pct": 48.1, "output_kw_max": 28.0, "final_year_of_manufacture": 2001, "raw": ["008053", "000011", "0", "2006/Jan/17 12:55", "Vokera", "Vokera", "Linea 28", "", "47-094-28", "1998", "2001", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "28", "28", "", "", "78.5", "68.4", "", "48.1", "", "2", "", "", "104", "1", "2", "125", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.7", "77.7", "", "", "", "", "78.4"]} -{"pcdb_id": 8055, "brand_name": "Vokera", "model_name": "Eclipse ESC", "model_qualifier": "", "winter_efficiency_pct": 84.9, "summer_efficiency_pct": 76.3, "comparative_hot_water_efficiency_pct": 53.7, "output_kw_max": 25.3, "final_year_of_manufacture": 2010, "raw": ["008055", "000011", "0", "2010/Oct/21 11:01", "Vokera", "Vokera", "Eclipse ESC", "", "47-094-24", "1996", "2010", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "25.3", "25.3", "", "", "84.9", "76.3", "", "53.7", "", "2", "", "", "104", "1", "2", "130", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.2", "89.3", "", "", "", "", "88.9"]} -{"pcdb_id": 8056, "brand_name": "Vokera", "model_name": "Linea Plus", "model_qualifier": "", "winter_efficiency_pct": 81.0, "summer_efficiency_pct": 70.9, "comparative_hot_water_efficiency_pct": 49.9, "output_kw_max": 30.0, "final_year_of_manufacture": 2000, "raw": ["008056", "000011", "0", "2006/Jan/17 12:55", "Vokera", "Vokera", "Linea Plus", "", "47-094-29", "1998", "2000", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "30", "30", "", "", "81.0", "70.9", "", "49.9", "", "2", "", "", "104", "1", "2", "160", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.4", "82.0", "", "", "", "", "82.1"]} -{"pcdb_id": 8057, "brand_name": "Vokera", "model_name": "Eclipse ESS", "model_qualifier": "", "winter_efficiency_pct": 84.9, "summer_efficiency_pct": 75.9, "comparative_hot_water_efficiency_pct": 55.5, "output_kw_max": 25.3, "final_year_of_manufacture": 2010, "raw": ["008057", "000011", "0", "2012/Mar/27 10:12", "Vokera", "Vokera", "Eclipse ESS", "", "41-094-10", "1996", "2010", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "25.3", "25.3", "", "", "84.9", "75.9", "", "55.5", "", "2", "", "", "102", "1", "2", "130", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.2", "89.3", "", "", "", "", "88.9"]} -{"pcdb_id": 8059, "brand_name": "Warmflow", "model_name": "120/150 Bluebird", "model_qualifier": "", "winter_efficiency_pct": 86.5, "summer_efficiency_pct": 74.8, "comparative_hot_water_efficiency_pct": 54.7, "output_kw_max": 43.95, "final_year_of_manufacture": null, "raw": ["008059", "000063", "0", "2019/Dec/19 11:37", "Warmflow Engineering", "Warmflow", "120/150 Bluebird", "", "", "1996", "current", "4", "1", "2", "1", "0", "", "", "1", "1", "2", "35.16", "43.95", "", "", "86.5", "74.8", "", "54.7", "", "2", "", "", "201", "1", "1", "150", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.9", "88.0", "", "", "", "", "87.6"]} -{"pcdb_id": 8060, "brand_name": "Warmflow", "model_name": "90/120 Bluebird", "model_qualifier": "", "winter_efficiency_pct": 85.4, "summer_efficiency_pct": 73.7, "comparative_hot_water_efficiency_pct": 53.8, "output_kw_max": 35.16, "final_year_of_manufacture": 2000, "raw": ["008060", "000063", "0", "2012/Mar/27 10:12", "Warmflow Engineering", "Warmflow", "90/120 Bluebird", "", "", "1996", "2000", "4", "1", "2", "1", "0", "", "", "1", "1", "2", "26.37", "35.16", "", "", "85.4", "73.7", "", "53.8", "", "2", "", "", "201", "1", "1", "150", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "84.8", "85.9", "", "", "", "", "85.7"]} -{"pcdb_id": 8061, "brand_name": "Warmflow", "model_name": "70/90 Bluebird", "model_qualifier": "", "winter_efficiency_pct": 83.0, "summer_efficiency_pct": 71.3, "comparative_hot_water_efficiency_pct": 52.1, "output_kw_max": 26.37, "final_year_of_manufacture": 2000, "raw": ["008061", "000063", "0", "2012/Mar/27 10:12", "Warmflow Engineering", "Warmflow", "70/90 Bluebird", "", "", "1996", "2000", "4", "1", "2", "1", "0", "", "", "1", "1", "2", "20.51", "26.37", "", "", "83.0", "71.3", "", "52.1", "", "2", "", "", "201", "1", "1", "150", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "83.1", "82.8", "", "", "", "", "82.9"]} -{"pcdb_id": 8062, "brand_name": "Warmflow", "model_name": "50/70 Bluebird", "model_qualifier": "", "winter_efficiency_pct": 86.5, "summer_efficiency_pct": 74.8, "comparative_hot_water_efficiency_pct": 54.7, "output_kw_max": 20.51, "final_year_of_manufacture": 2000, "raw": ["008062", "000063", "0", "2012/Mar/27 10:12", "Warmflow Engineering", "Warmflow", "50/70 Bluebird", "", "", "1996", "2000", "4", "1", "2", "1", "0", "", "", "1", "1", "2", "14.65", "20.51", "", "", "86.5", "74.8", "", "54.7", "", "2", "", "", "201", "1", "1", "145", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.9", "88.8", "", "", "", "", "88.3"]} -{"pcdb_id": 8063, "brand_name": "Ideal", "model_name": "Mexico Super", "model_qualifier": "CF3/70", "winter_efficiency_pct": 73.6, "summer_efficiency_pct": 63.5, "comparative_hot_water_efficiency_pct": 46.3, "output_kw_max": 20.5, "final_year_of_manufacture": 2001, "raw": ["008063", "000008", "0", "2018/Oct/15 12:00", "Caradon Plumbing", "Ideal", "Mexico Super", "CF3/70", "G.C.No 41 348 14", "", "2001", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "17.6", "20.5", "", "", "73.6", "63.5", "", "46.3", "", "2", "", "", "101", "2", "1", "5", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "80.4", "77.9", "", "", "", "", "78.4"]} -{"pcdb_id": 8064, "brand_name": "Ideal", "model_name": "Mexico Super", "model_qualifier": "CF3/80", "winter_efficiency_pct": 73.2, "summer_efficiency_pct": 63.1, "comparative_hot_water_efficiency_pct": 46.1, "output_kw_max": 23.4, "final_year_of_manufacture": 2001, "raw": ["008064", "000008", "0", "2018/Oct/15 12:00", "Caradon Plumbing", "Ideal", "Mexico Super", "CF3/80", "G.C.No 41 348 16", "", "2001", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "20.5", "23.4", "", "", "73.2", "63.1", "", "46.1", "", "2", "", "", "101", "2", "1", "5", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.5", "78.2", "", "", "", "", "78.4"]} -{"pcdb_id": 8065, "brand_name": "Ideal", "model_name": "Mexico Super", "model_qualifier": "RS3/40", "winter_efficiency_pct": 73.7, "summer_efficiency_pct": 63.6, "comparative_hot_water_efficiency_pct": 46.5, "output_kw_max": 11.7, "final_year_of_manufacture": 2001, "raw": ["008065", "000008", "0", "2018/Oct/15 12:00", "Caradon Plumbing", "Ideal", "Mexico Super", "RS3/40", "G.C.No 41 349 27", "", "2001", "1", "1", "1", "1", "0", "", "", "1", "2", "1", "8.8", "11.7", "", "", "73.7", "63.6", "", "46.5", "", "2", "", "", "101", "2", "1", "5", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.6", "79.1", "", "", "", "", "79.2"]} -{"pcdb_id": 8066, "brand_name": "Ideal", "model_name": "Mexico Super", "model_qualifier": "RS3/50", "winter_efficiency_pct": 73.0, "summer_efficiency_pct": 62.9, "comparative_hot_water_efficiency_pct": 45.9, "output_kw_max": 14.7, "final_year_of_manufacture": 2001, "raw": ["008066", "000008", "0", "2018/Oct/15 12:00", "Caradon Plumbing", "Ideal", "Mexico Super", "RS3/50", "G.C.No 41 349 28", "", "2001", "1", "1", "1", "1", "0", "", "", "1", "2", "1", "11.7", "14.7", "", "", "73.0", "62.9", "", "45.9", "", "2", "", "", "101", "2", "1", "5", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.9", "77.2", "", "", "", "", "77.7"]} -{"pcdb_id": 8067, "brand_name": "Ideal", "model_name": "Mexico Super", "model_qualifier": "RS3/60", "winter_efficiency_pct": 74.9, "summer_efficiency_pct": 64.8, "comparative_hot_water_efficiency_pct": 47.3, "output_kw_max": 17.6, "final_year_of_manufacture": 2001, "raw": ["008067", "000008", "0", "2018/Oct/15 12:00", "Caradon Plumbing", "Ideal", "Mexico Super", "RS3/60", "G.C.No 41 349 29", "", "2001", "1", "1", "1", "1", "0", "", "", "1", "2", "1", "14.7", "17.6", "", "", "74.9", "64.8", "", "47.3", "", "2", "", "", "101", "2", "1", "5", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "80.2", "80.8", "", "", "", "", "80.7"]} -{"pcdb_id": 8068, "brand_name": "Ideal", "model_name": "Mexico Super", "model_qualifier": "RS3/100", "winter_efficiency_pct": 73.4, "summer_efficiency_pct": 63.3, "comparative_hot_water_efficiency_pct": 46.2, "output_kw_max": 29.3, "final_year_of_manufacture": 2001, "raw": ["008068", "000008", "0", "2018/Oct/15 12:00", "Caradon Plumbing", "Ideal", "Mexico Super", "RS3/100", "G.C.No 41 349 32", "", "2001", "1", "1", "1", "1", "0", "", "", "1", "2", "1", "23.4", "29.3", "", "", "73.4", "63.3", "", "46.2", "", "2", "", "", "101", "2", "1", "5", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.6", "78.3", "", "", "", "", "78.6"]} -{"pcdb_id": 8069, "brand_name": "Ideal", "model_name": "Mexico Super", "model_qualifier": "RS3/70", "winter_efficiency_pct": 73.6, "summer_efficiency_pct": 63.5, "comparative_hot_water_efficiency_pct": 46.4, "output_kw_max": 20.5, "final_year_of_manufacture": 2001, "raw": ["008069", "000008", "0", "2018/Oct/15 12:00", "Caradon Plumbing", "Ideal", "Mexico Super", "RS3/70", "G.C.No 41 349 30", "", "2001", "1", "1", "1", "1", "0", "", "", "1", "2", "1", "17.6", "20.5", "", "", "73.6", "63.5", "", "46.4", "", "2", "", "", "101", "2", "1", "5", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.8", "78.7", "", "", "", "", "78.9"]} -{"pcdb_id": 8070, "brand_name": "Ideal", "model_name": "Mexico Super", "model_qualifier": "RS3/80", "winter_efficiency_pct": 72.9, "summer_efficiency_pct": 62.8, "comparative_hot_water_efficiency_pct": 45.9, "output_kw_max": 23.4, "final_year_of_manufacture": 2001, "raw": ["008070", "000008", "0", "2018/Oct/15 12:00", "Caradon Plumbing", "Ideal", "Mexico Super", "RS3/80", "G.C.No 41 349 31", "", "2001", "1", "1", "1", "1", "0", "", "", "1", "2", "1", "20.5", "23.4", "", "", "72.9", "62.8", "", "45.9", "", "2", "", "", "101", "2", "1", "5", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "78.7", "78.3", "", "", "", "", "78.4"]} -{"pcdb_id": 8071, "brand_name": "Ideal", "model_name": "Mexico Super", "model_qualifier": "RS3/125", "winter_efficiency_pct": 73.6, "summer_efficiency_pct": 63.5, "comparative_hot_water_efficiency_pct": 46.4, "output_kw_max": 35.8, "final_year_of_manufacture": 2001, "raw": ["008071", "000008", "0", "2018/Oct/15 12:00", "Caradon Plumbing", "Ideal", "Mexico Super", "RS3/125", "G.C.No 41 349 33", "", "2001", "1", "1", "1", "1", "0", "", "", "1", "2", "1", "29.3", "35.8", "", "", "73.6", "63.5", "", "46.4", "", "2", "", "", "101", "2", "1", "5", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.3", "79.2", "", "", "", "", "79.2"]} -{"pcdb_id": 8072, "brand_name": "Ideal", "model_name": "Mexico Super", "model_qualifier": "CF3/60P", "winter_efficiency_pct": 75.3, "summer_efficiency_pct": 65.2, "comparative_hot_water_efficiency_pct": 47.6, "output_kw_max": 18.1, "final_year_of_manufacture": 2001, "raw": ["008072", "000008", "0", "2018/Oct/15 12:00", "Caradon Plumbing", "Ideal", "Mexico Super", "CF3/60P", "G.C.No 41 348 99", "", "2001", "2", "1", "1", "1", "0", "", "", "1", "1", "1", "18.1", "18.1", "", "", "75.3", "65.2", "", "47.6", "", "2", "0", "", "101", "2", "1", "5", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.5", "80.3", "", "", "", "", "80.5"]} -{"pcdb_id": 8073, "brand_name": "Ideal", "model_name": "Mexico Super", "model_qualifier": "CF3/75P", "winter_efficiency_pct": 74.9, "summer_efficiency_pct": 64.8, "comparative_hot_water_efficiency_pct": 47.3, "output_kw_max": 22.2, "final_year_of_manufacture": 2001, "raw": ["008073", "000008", "0", "2018/Oct/15 12:00", "Caradon Plumbing", "Ideal", "Mexico Super", "CF3/75P", "G.C.No 41 349 23", "", "2001", "2", "1", "1", "1", "0", "", "", "1", "1", "1", "22.2", "22.2", "", "", "74.9", "64.8", "", "47.3", "", "2", "0", "", "101", "2", "1", "5", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.2", "79.8", "", "", "", "", "80.0"]} -{"pcdb_id": 8074, "brand_name": "Ideal", "model_name": "Mexico Super", "model_qualifier": "RS3/60P", "winter_efficiency_pct": 76.1, "summer_efficiency_pct": 66.0, "comparative_hot_water_efficiency_pct": 48.2, "output_kw_max": 17.5, "final_year_of_manufacture": 2001, "raw": ["008074", "000008", "0", "2018/Oct/15 12:00", "Caradon Plumbing", "Ideal", "Mexico Super", "RS3/60P", "G.C.No 41 349 34", "", "2001", "2", "1", "1", "1", "0", "", "", "1", "2", "1", "17.5", "17.5", "", "", "76.1", "66.0", "", "48.2", "", "2", "0", "", "101", "2", "1", "5", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.4", "82.1", "", "", "", "", "81.9"]} -{"pcdb_id": 8075, "brand_name": "Ideal", "model_name": "Mexico Super", "model_qualifier": "RS3/75P", "winter_efficiency_pct": 76.2, "summer_efficiency_pct": 66.1, "comparative_hot_water_efficiency_pct": 48.3, "output_kw_max": 23.2, "final_year_of_manufacture": 2001, "raw": ["008075", "000008", "0", "2018/Oct/15 12:00", "Caradon Plumbing", "Ideal", "Mexico Super", "RS3/75P", "G.C.No 41 349 35", "", "2001", "2", "1", "1", "1", "0", "", "", "1", "2", "1", "23.2", "23.2", "", "", "76.2", "66.1", "", "48.3", "", "2", "0", "", "101", "2", "1", "5", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.1", "81.6", "", "", "", "", "81.7"]} -{"pcdb_id": 8076, "brand_name": "Ideal", "model_name": "Mexico Super", "model_qualifier": "RS3/100P", "winter_efficiency_pct": 75.6, "summer_efficiency_pct": 65.5, "comparative_hot_water_efficiency_pct": 47.8, "output_kw_max": 28.8, "final_year_of_manufacture": 2001, "raw": ["008076", "000008", "0", "2018/Oct/15 12:00", "Caradon Plumbing", "Ideal", "Mexico Super", "RS3/100P", "G.C.No 41 349 36", "", "2001", "2", "1", "1", "1", "0", "", "", "1", "2", "1", "28.8", "28.8", "", "", "75.6", "65.5", "", "47.8", "", "2", "0", "", "101", "2", "1", "5", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "80.5", "81.9", "", "", "", "", "81.6"]} -{"pcdb_id": 8077, "brand_name": "Worcester", "model_name": "28i", "model_qualifier": "RSF", "winter_efficiency_pct": 78.9, "summer_efficiency_pct": 68.8, "comparative_hot_water_efficiency_pct": 48.4, "output_kw_max": 28.0, "final_year_of_manufacture": 2003, "raw": ["008077", "000035", "0", "2020/Sep/02 14:14", "Worcester Heat Systems", "Worcester", "28i", "RSF", "47 311 54", "2000", "2003", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "28", "28", "", "", "78.9", "68.8", "", "48.4", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "83.9", "77.3", "", "", "", "", "78.6"]} -{"pcdb_id": 8083, "brand_name": "Kidd VHE", "model_name": "1", "model_qualifier": "Kerosene", "winter_efficiency_pct": 85.8, "summer_efficiency_pct": 78.0, "comparative_hot_water_efficiency_pct": 57.0, "output_kw_max": 27.2, "final_year_of_manufacture": null, "raw": ["008083", "000204", "0", "2012/Mar/27 10:12", "Archie Kidd (Thermal)", "Kidd VHE", "1", "Kerosene", "", "1982", "current", "4", "1", "2", "1", "0", "", "", "2", "3", "1", "17.6", "27.2", "", "", "85.8", "78.0", "", "57.0", "", "2", "", "", "201", "1", "1", "90", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.4", "89.3", "", "", "", "", "89.7"]} -{"pcdb_id": 8086, "brand_name": "Glow-worm", "model_name": "Energysaver Combi 80", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 56.4, "output_kw_max": 24.6, "final_year_of_manufacture": 2003, "raw": ["008086", "000207", "0", "2012/Mar/26 14:26", "Hepworth Heating", "Glow-worm", "Energysaver Combi 80", "", "47-047-01", "1998", "2003", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.6", "24.6", "", "", "88.8", "80.2", "", "56.4", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "0", "", "0005", "", "", "", "", "", "", "", "", "89.0", "98.4", "", "", "", "", "96.6"]} -{"pcdb_id": 8087, "brand_name": "Glow-worm", "model_name": "Energysaver Combi 100", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 56.3, "output_kw_max": 28.9, "final_year_of_manufacture": 2003, "raw": ["008087", "000207", "0", "2012/Mar/26 14:24", "Hepworth Heating", "Glow-worm", "Energysaver Combi 100", "", "47-047-02", "1999", "2003", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28.9", "28.9", "", "", "88.6", "80.0", "", "56.3", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "0", "", "0005", "", "", "", "", "", "", "", "", "88.6", "98.1", "", "", "", "", "96.3"]} -{"pcdb_id": 8088, "brand_name": "Saunier Duval", "model_name": "Ecosy 24E", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 56.4, "output_kw_max": 24.6, "final_year_of_manufacture": 2003, "raw": ["008088", "000206", "0", "2012/Mar/26 14:22", "Hepworth Heating", "Saunier Duval", "Ecosy 24E", "", "47-920-03", "1996", "2003", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.6", "24.6", "", "", "88.8", "80.2", "", "56.4", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "0", "", "0005", "", "", "", "", "", "", "", "", "89.0", "98.4", "", "", "", "", "96.6"]} -{"pcdb_id": 8089, "brand_name": "Saunier Duval", "model_name": "Ecosy 28E", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 56.3, "output_kw_max": 28.9, "final_year_of_manufacture": 2003, "raw": ["008089", "000206", "0", "2012/Mar/26 14:18", "Hepworth Heating", "Saunier Duval", "Ecosy 28E", "", "47-920-04", "1997", "2003", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28.9", "28.9", "", "", "88.6", "80.0", "", "56.3", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "0", "", "0005", "", "", "", "", "", "", "", "", "88.6", "98.1", "", "", "", "", "96.3"]} -{"pcdb_id": 8090, "brand_name": "Saunier Duval", "model_name": "Ecosy SB28E", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 28.9, "final_year_of_manufacture": 2003, "raw": ["008090", "000206", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Saunier Duval", "Ecosy SB28E", "", "41-920-22", "1997", "2003", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "28.9", "28.9", "", "", "88.6", "79.6", "", "58.2", "", "2", "", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.6", "98.1", "", "", "", "", "96.3"]} -{"pcdb_id": 8091, "brand_name": "Saunier Duval", "model_name": "Ecosy SB24E", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 24.6, "final_year_of_manufacture": 2003, "raw": ["008091", "000206", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Saunier Duval", "Ecosy SB24E", "", "41-920-01", "1997", "2003", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24.6", "24.6", "", "", "88.8", "79.8", "", "58.3", "", "2", "", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.0", "98.4", "", "", "", "", "96.6"]} -{"pcdb_id": 8093, "brand_name": "Boulter", "model_name": "Camray 5", "model_qualifier": "150/200", "winter_efficiency_pct": 84.7, "summer_efficiency_pct": 73.0, "comparative_hot_water_efficiency_pct": 53.3, "output_kw_max": 58.6, "final_year_of_manufacture": 2001, "raw": ["008093", "000041", "0", "2012/Mar/27 10:12", "Boulter Boilers", "Boulter", "Camray 5", "150/200", "", "2000", "2001", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "43.9", "58.6", "", "", "84.7", "73.0", "", "53.3", "", "2", "", "", "201", "1", "1", "150", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "83.8", "85.6", "", "", "", "", "85.3"]} -{"pcdb_id": 8096, "brand_name": "Boulter", "model_name": "Camray 5", "model_qualifier": "100/140 System", "winter_efficiency_pct": 81.2, "summer_efficiency_pct": 69.5, "comparative_hot_water_efficiency_pct": 50.8, "output_kw_max": 41.0, "final_year_of_manufacture": 2001, "raw": ["008096", "000041", "0", "2012/Mar/27 10:12", "Boulter Boilers", "Boulter", "Camray 5", "100/140 System", "", "2000", "2001", "4", "1", "1", "1", "0", "", "", "1", "3", "2", "29.3", "41.0", "", "", "81.2", "69.5", "", "50.8", "", "2", "", "", "201", "1", "1", "115", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.8", "80.7", "", "", "", "", "80.9"]} -{"pcdb_id": 8097, "brand_name": "Boulter", "model_name": "Camray 5", "model_qualifier": "100/140 Utility", "winter_efficiency_pct": 81.2, "summer_efficiency_pct": 69.5, "comparative_hot_water_efficiency_pct": 50.8, "output_kw_max": 41.0, "final_year_of_manufacture": 2001, "raw": ["008097", "000041", "0", "2012/Mar/27 10:12", "Boulter Boilers", "Boulter", "Camray 5", "100/140 Utility", "", "2000", "2001", "4", "1", "1", "1", "0", "", "", "1", "3", "2", "29.3", "41.0", "", "", "81.2", "69.5", "", "50.8", "", "2", "", "", "201", "1", "1", "115", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.8", "80.7", "", "", "", "", "80.9"]} -{"pcdb_id": 8098, "brand_name": "Boulter", "model_name": "Camray 5", "model_qualifier": "100/140", "winter_efficiency_pct": 81.2, "summer_efficiency_pct": 69.5, "comparative_hot_water_efficiency_pct": 50.8, "output_kw_max": 41.0, "final_year_of_manufacture": 2001, "raw": ["008098", "000041", "0", "2012/Mar/27 10:12", "Boulter Boilers", "Boulter", "Camray 5", "100/140", "", "2000", "2001", "4", "1", "1", "1", "0", "", "", "1", "3", "2", "29.3", "41.0", "", "", "81.2", "69.5", "", "50.8", "", "2", "", "", "201", "1", "1", "115", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.8", "80.7", "", "", "", "", "80.9"]} -{"pcdb_id": 8099, "brand_name": "Chaffoteaux et Maury", "model_name": "Britony Combi 100", "model_qualifier": "", "winter_efficiency_pct": 79.3, "summer_efficiency_pct": 69.2, "comparative_hot_water_efficiency_pct": 48.7, "output_kw_max": 28.0, "final_year_of_manufacture": 2002, "raw": ["008099", "000010", "0", "2006/Jan/17 12:55", "Chaffoteaux et Maury", "Chaffoteaux et Maury", "Britony Combi 100", "", "", "1996", "2002", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "28.0", "28.0", "", "", "79.3", "69.2", "", "48.7", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.5", "78.5", "", "", "", "", "79.2"]} -{"pcdb_id": 8100, "brand_name": "Chaffoteaux et Maury", "model_name": "Britony Combi 80", "model_qualifier": "", "winter_efficiency_pct": 77.5, "summer_efficiency_pct": 67.4, "comparative_hot_water_efficiency_pct": 47.4, "output_kw_max": 23.25, "final_year_of_manufacture": 2002, "raw": ["008100", "000010", "0", "2006/Jan/17 12:55", "Chaffoteaux et Maury", "Chaffoteaux et Maury", "Britony Combi 80", "", "", "1996", "2002", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "23.25", "23.25", "", "", "77.5", "67.4", "", "47.4", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.4", "76.1", "", "", "", "", "77.1"]} -{"pcdb_id": 8101, "brand_name": "Chaffoteaux et Maury", "model_name": "Calydra 80", "model_qualifier": "", "winter_efficiency_pct": 77.5, "summer_efficiency_pct": 67.4, "comparative_hot_water_efficiency_pct": 47.4, "output_kw_max": 23.25, "final_year_of_manufacture": 2002, "raw": ["008101", "000010", "0", "2006/Jan/17 12:55", "Chaffoteaux et Maury", "Chaffoteaux et Maury", "Calydra 80", "", "49AQ566", "1998", "2002", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "23.25", "23.25", "", "", "77.5", "67.4", "", "47.4", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.4", "76.1", "", "", "", "", "77.1"]} -{"pcdb_id": 8102, "brand_name": "Chaffoteaux et Maury", "model_name": "Calydra 100", "model_qualifier": "", "winter_efficiency_pct": 79.3, "summer_efficiency_pct": 69.2, "comparative_hot_water_efficiency_pct": 48.7, "output_kw_max": 28.0, "final_year_of_manufacture": 2003, "raw": ["008102", "000010", "0", "2006/Jan/17 12:55", "Chaffoteaux et Maury", "Chaffoteaux et Maury", "Calydra 100", "", "", "1998", "2003", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "28.0", "28.0", "", "", "79.3", "69.2", "", "48.7", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.5", "78.5", "", "", "", "", "79.2"]} -{"pcdb_id": 8103, "brand_name": "Chaffoteaux et Maury", "model_name": "Britony System 40", "model_qualifier": "", "winter_efficiency_pct": 77.1, "summer_efficiency_pct": 67.0, "comparative_hot_water_efficiency_pct": 47.1, "output_kw_max": 12.0, "final_year_of_manufacture": 2002, "raw": ["008103", "000010", "0", "2006/Jan/17 12:55", "Chaffoteaux et Maury", "Chaffoteaux et Maury", "Britony System 40", "", "", "1997", "2002", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "12.0", "12.0", "", "", "77.1", "67.0", "", "47.1", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "78.9", "77.8", "", "", "", "", "78.0"]} -{"pcdb_id": 8104, "brand_name": "Vaillant", "model_name": "Ecomax", "model_qualifier": "828/1E", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 55.8, "output_kw_max": 22.4, "final_year_of_manufacture": 2001, "raw": ["008104", "000031", "0", "2006/Jan/17 12:55", "Vaillant", "Vaillant", "Ecomax", "828/1E", "VUW GB 286 E-C", "2000", "2001", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "22.4", "22.4", "", "", "88.0", "79.4", "", "55.8", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "96.7", "", "", "", "", "95.1"]} -{"pcdb_id": 8105, "brand_name": "Vaillant", "model_name": "Ecomax", "model_qualifier": "824/1E", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 55.8, "output_kw_max": 18.4, "final_year_of_manufacture": 2001, "raw": ["008105", "000031", "0", "2006/Jan/17 12:55", "Vaillant", "Vaillant", "Ecomax", "824/1E", "VUW GB 246 E-C", "2000", "2001", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "18.4", "18.4", "", "", "88.0", "79.4", "", "55.8", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.2", "96.6", "", "", "", "", "95.0"]} -{"pcdb_id": 8106, "brand_name": "Vaillant", "model_name": "Ecomax", "model_qualifier": "622E", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 22.4, "final_year_of_manufacture": 2001, "raw": ["008106", "000031", "0", "2012/Mar/27 10:12", "Vaillant", "Vaillant", "Ecomax", "622E", "VU GB 246 E-C", "2000", "2001", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "22.4", "22.4", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "96.7", "", "", "", "", "95.1"]} -{"pcdb_id": 8107, "brand_name": "Vaillant", "model_name": "Ecomax", "model_qualifier": "618E", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 18.4, "final_year_of_manufacture": 2001, "raw": ["008107", "000031", "0", "2012/Mar/27 10:12", "Vaillant", "Vaillant", "Ecomax", "618E", "VU GB 196 E-C", "2000", "2001", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18.4", "18.4", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.2", "96.6", "", "", "", "", "95.0"]} -{"pcdb_id": 8108, "brand_name": "Vaillant", "model_name": "Turbomax Plus", "model_qualifier": "824E", "winter_efficiency_pct": 80.6, "summer_efficiency_pct": 70.5, "comparative_hot_water_efficiency_pct": 49.6, "output_kw_max": 24.0, "final_year_of_manufacture": 2010, "raw": ["008108", "000031", "0", "2010/Jan/28 08:47", "Vaillant", "Vaillant", "Turbomax Plus", "824E", "VUW GB 242 - 5E", "2000", "2010", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "24.0", "24.0", "", "", "80.6", "70.5", "", "49.6", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.4", "82.2", "", "", "", "", "82.0"]} -{"pcdb_id": 8109, "brand_name": "Vaillant", "model_name": "Turbomax Plus", "model_qualifier": "828E", "winter_efficiency_pct": 80.6, "summer_efficiency_pct": 70.5, "comparative_hot_water_efficiency_pct": 49.6, "output_kw_max": 28.0, "final_year_of_manufacture": 2010, "raw": ["008109", "000031", "0", "2010/Jan/28 08:43", "Vaillant", "Vaillant", "Turbomax Plus", "828E", "VUW GB 282 - 5E", "2000", "2010", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "28.0", "28.0", "", "", "80.6", "70.5", "", "49.6", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.5", "82.0", "", "", "", "", "81.9"]} -{"pcdb_id": 8110, "brand_name": "Vaillant", "model_name": "Turbomax Pro", "model_qualifier": "24E", "winter_efficiency_pct": 80.6, "summer_efficiency_pct": 70.5, "comparative_hot_water_efficiency_pct": 49.6, "output_kw_max": 24.0, "final_year_of_manufacture": 2000, "raw": ["008110", "000031", "0", "2006/Jan/17 12:55", "Vaillant", "Vaillant", "Turbomax Pro", "24E", "VUW GB 242 - 3E", "2000", "2000", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "24.0", "24.0", "", "", "80.6", "70.5", "", "49.6", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.4", "82.2", "", "", "", "", "82.0"]} -{"pcdb_id": 8117, "brand_name": "Halstead", "model_name": "Wickes LW", "model_qualifier": "40Ci", "winter_efficiency_pct": 76.2, "summer_efficiency_pct": 66.1, "comparative_hot_water_efficiency_pct": 48.3, "output_kw_max": 11.72, "final_year_of_manufacture": 2001, "raw": ["008117", "000019", "0", "2012/Mar/27 10:12", "Halstead Boilers", "Halstead", "Wickes LW", "40Ci", "GC No41-333-51", "", "2001", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "8.79", "11.72", "", "", "76.2", "66.1", "", "48.3", "", "2", "", "", "101", "1", "1", "35", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "78.5", "77.1", "", "", "", "", "77.4"]} -{"pcdb_id": 8118, "brand_name": "Halstead", "model_name": "Wickes LW", "model_qualifier": "50Ci", "winter_efficiency_pct": 77.2, "summer_efficiency_pct": 67.1, "comparative_hot_water_efficiency_pct": 49.0, "output_kw_max": 14.65, "final_year_of_manufacture": 2001, "raw": ["008118", "000019", "0", "2012/Mar/27 10:12", "Halstead Boilers", "Halstead", "Wickes LW", "50Ci", "GC No41-333-52", "", "2001", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "11.72", "14.65", "", "", "77.2", "67.1", "", "49.0", "", "2", "", "", "101", "1", "1", "35", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.4", "78.2", "", "", "", "", "78.4"]} -{"pcdb_id": 8119, "brand_name": "Halstead", "model_name": "Wickes LW", "model_qualifier": "60Ci", "winter_efficiency_pct": 76.5, "summer_efficiency_pct": 66.4, "comparative_hot_water_efficiency_pct": 48.5, "output_kw_max": 17.58, "final_year_of_manufacture": 2001, "raw": ["008119", "000019", "0", "2012/Mar/27 10:12", "Halstead Boilers", "Halstead", "Wickes LW", "60Ci", "GC No41-333-53", "", "2001", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "17.58", "17.58", "", "", "76.5", "66.4", "", "48.5", "", "2", "", "", "101", "1", "1", "35", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "78.6", "77.6", "", "", "", "", "77.8"]} -{"pcdb_id": 8120, "brand_name": "Halstead", "model_name": "Wickes", "model_qualifier": "90", "winter_efficiency_pct": 78.2, "summer_efficiency_pct": 68.1, "comparative_hot_water_efficiency_pct": 47.9, "output_kw_max": 23.45, "final_year_of_manufacture": 2001, "raw": ["008120", "000019", "0", "2006/Jan/17 12:55", "Halstead Boilers", "Halstead", "Wickes", "90", "GC No47-333-09", "", "2001", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "23.45", "23.45", "", "", "78.2", "68.1", "", "47.9", "", "2", "", "", "104", "1", "2", "160", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.6", "77.2", "", "", "", "", "78.1"]} -{"pcdb_id": 8121, "brand_name": "Halstead", "model_name": "Best", "model_qualifier": "30", "winter_efficiency_pct": 76.8, "summer_efficiency_pct": 66.7, "comparative_hot_water_efficiency_pct": 48.7, "output_kw_max": 8.79, "final_year_of_manufacture": 2001, "raw": ["008121", "000019", "0", "2012/Mar/27 10:12", "Halstead Boilers", "Halstead", "Best", "30", "GC No41-333-50", "", "2001", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "5.86", "8.79", "", "", "76.8", "66.7", "", "48.7", "", "2", "", "", "101", "1", "1", "35", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.6", "77.2", "", "", "", "", "77.7"]} -{"pcdb_id": 8122, "brand_name": "Halstead", "model_name": "Best", "model_qualifier": "40", "winter_efficiency_pct": 76.5, "summer_efficiency_pct": 66.4, "comparative_hot_water_efficiency_pct": 48.5, "output_kw_max": 11.72, "final_year_of_manufacture": 2001, "raw": ["008122", "000019", "0", "2012/Mar/27 10:12", "Halstead Boilers", "Halstead", "Best", "40", "GC No41-333-51", "", "2001", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "8.79", "11.72", "", "", "76.5", "66.4", "", "48.5", "", "2", "", "", "101", "1", "1", "35", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.1", "77.1", "", "", "", "", "77.5"]} -{"pcdb_id": 8123, "brand_name": "Halstead", "model_name": "Best", "model_qualifier": "50", "winter_efficiency_pct": 77.3, "summer_efficiency_pct": 67.2, "comparative_hot_water_efficiency_pct": 49.1, "output_kw_max": 14.65, "final_year_of_manufacture": 2001, "raw": ["008123", "000019", "0", "2012/Mar/27 10:12", "Halstead Boilers", "Halstead", "Best", "50", "GC No41-333-52", "", "2001", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "11.72", "14.65", "", "", "77.3", "67.2", "", "49.1", "", "2", "", "", "101", "1", "1", "35", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.6", "78.2", "", "", "", "", "78.5"]} -{"pcdb_id": 8124, "brand_name": "Halstead", "model_name": "Best", "model_qualifier": "60", "winter_efficiency_pct": 76.5, "summer_efficiency_pct": 66.4, "comparative_hot_water_efficiency_pct": 48.5, "output_kw_max": 17.58, "final_year_of_manufacture": 2001, "raw": ["008124", "000019", "0", "2012/Mar/27 10:12", "Halstead Boilers", "Halstead", "Best", "60", "GC No41-333-53", "", "2001", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "17.58", "17.58", "", "", "76.5", "66.4", "", "48.5", "", "2", "", "", "101", "1", "1", "35", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "78.6", "77.6", "", "", "", "", "77.8"]} -{"pcdb_id": 8125, "brand_name": "Halstead", "model_name": "Best", "model_qualifier": "80", "winter_efficiency_pct": 77.1, "summer_efficiency_pct": 67.0, "comparative_hot_water_efficiency_pct": 48.9, "output_kw_max": 23.44, "final_year_of_manufacture": 2001, "raw": ["008125", "000019", "0", "2012/Mar/27 10:12", "Halstead Boilers", "Halstead", "Best", "80", "GC No41-333-56", "", "2001", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "17.57", "23.44", "", "", "77.1", "67.0", "", "48.9", "", "2", "", "", "101", "1", "1", "35", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.2", "78.2", "", "", "", "", "78.4"]} -{"pcdb_id": 8126, "brand_name": "Halstead", "model_name": "Best", "model_qualifier": "40", "winter_efficiency_pct": 78.3, "summer_efficiency_pct": 68.2, "comparative_hot_water_efficiency_pct": 49.8, "output_kw_max": 12.15, "final_year_of_manufacture": 2002, "raw": ["008126", "000019", "0", "2012/Mar/27 10:12", "Halstead Boilers", "Halstead", "Best", "40", "GC No41-333-54", "", "2002", "2", "2", "1", "1", "0", "", "", "1", "2", "2", "12.15", "12.15", "", "", "78.3", "68.2", "", "49.8", "", "2", "0", "", "101", "1", "1", "35", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "80.9", "78.8", "", "", "", "", "79.2"]} -{"pcdb_id": 8127, "brand_name": "Halstead", "model_name": "Best", "model_qualifier": "60", "winter_efficiency_pct": 77.7, "summer_efficiency_pct": 67.6, "comparative_hot_water_efficiency_pct": 49.4, "output_kw_max": 18.0, "final_year_of_manufacture": 2002, "raw": ["008127", "000019", "0", "2012/Mar/27 10:12", "Halstead Boilers", "Halstead", "Best", "60", "GC No41-333-55", "", "2002", "2", "2", "1", "1", "0", "", "", "1", "2", "2", "18", "18", "", "", "77.7", "67.6", "", "49.4", "", "2", "0", "", "101", "1", "1", "35", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.9", "78.7", "", "", "", "", "79.0"]} -{"pcdb_id": 8128, "brand_name": "Halstead", "model_name": "Finest", "model_qualifier": "", "winter_efficiency_pct": 78.2, "summer_efficiency_pct": 68.1, "comparative_hot_water_efficiency_pct": 47.9, "output_kw_max": 23.45, "final_year_of_manufacture": 2001, "raw": ["008128", "000019", "0", "2010/Sep/30 11:12", "Halstead Boilers", "Halstead", "Finest", "", "GC No47-333-06", "", "2001", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "23.45", "23.45", "", "", "78.2", "68.1", "", "47.9", "", "2", "", "", "104", "1", "2", "160", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.6", "77.2", "", "", "", "", "78.1"]} -{"pcdb_id": 8129, "brand_name": "Halstead", "model_name": "Finest Gold", "model_qualifier": "", "winter_efficiency_pct": 78.2, "summer_efficiency_pct": 68.1, "comparative_hot_water_efficiency_pct": 47.9, "output_kw_max": 23.45, "final_year_of_manufacture": 2001, "raw": ["008129", "000019", "0", "2006/Jan/17 12:55", "Halstead Boilers", "Halstead", "Finest Gold", "", "GC No47-333-07", "", "2001", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "23.45", "23.45", "", "", "78.2", "68.1", "", "47.9", "", "2", "", "", "104", "1", "2", "160", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.6", "77.2", "", "", "", "", "78.1"]} -{"pcdb_id": 8130, "brand_name": "Halstead", "model_name": "Finest", "model_qualifier": "", "winter_efficiency_pct": 78.5, "summer_efficiency_pct": 68.4, "comparative_hot_water_efficiency_pct": 48.1, "output_kw_max": 23.45, "final_year_of_manufacture": 2002, "raw": ["008130", "000019", "0", "2006/Jan/17 12:55", "Halstead Boilers", "Halstead", "Finest", "", "GC No47-333-08", "", "2002", "2", "2", "1", "2", "0", "", "", "1", "2", "2", "23.45", "23.45", "", "", "78.5", "68.4", "", "48.1", "", "2", "0", "", "104", "1", "2", "160", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.2", "78.2", "", "", "", "", "78.8"]} -{"pcdb_id": 8131, "brand_name": "Vaillant", "model_name": "Ecomax", "model_qualifier": "613E", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 13.5, "final_year_of_manufacture": 2001, "raw": ["008131", "000031", "0", "2012/Mar/27 10:12", "Vaillant", "Vaillant", "Ecomax", "613E", "VU GB 126 E-C", "2000", "2001", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "13.5", "13.5", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "96.6", "", "", "", "", "95.0"]} -{"pcdb_id": 8132, "brand_name": "Malvern", "model_name": "tentwenty", "model_qualifier": "", "winter_efficiency_pct": 84.7, "summer_efficiency_pct": 77.1, "comparative_hot_water_efficiency_pct": 56.3, "output_kw_max": 17.0, "final_year_of_manufacture": null, "raw": ["008132", "000023", "0", "2012/Mar/27 10:12", "Malvern Boilers", "Malvern", "tentwenty", "", "GC No 41.555.17", "2000", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "10.3", "17", "", "", "84.7", "77.1", "", "56.3", "", "2", "", "", "101", "1", "1", "40", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "87.8", "92.1", "", "", "", "", "91.3"]} -{"pcdb_id": 8133, "brand_name": "Malvern", "model_name": "twentytwentysix", "model_qualifier": "", "winter_efficiency_pct": 84.0, "summer_efficiency_pct": 76.4, "comparative_hot_water_efficiency_pct": 55.8, "output_kw_max": 23.5, "final_year_of_manufacture": null, "raw": ["008133", "000023", "0", "2012/Mar/27 10:12", "Malvern Boilers", "Malvern", "twentytwentysix", "", "GC No 41.555.18", "2000", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "20.6", "23.5", "", "", "84.0", "76.4", "", "55.8", "", "2", "", "", "101", "1", "1", "40", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "87.8", "90.2", "", "", "", "", "89.7"]} -{"pcdb_id": 8134, "brand_name": "Alpha", "model_name": "CB24X", "model_qualifier": "", "winter_efficiency_pct": 80.1, "summer_efficiency_pct": 70.0, "comparative_hot_water_efficiency_pct": 49.2, "output_kw_max": 23.3, "final_year_of_manufacture": 2005, "raw": ["008134", "000001", "0", "2011/Sep/06 13:08", "Alpha Therm", "Alpha", "CB24X", "", "", "2000", "2005", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "23.3", "23.3", "", "", "80.1", "70.0", "", "49.2", "", "2", "", "", "104", "1", "2", "170", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.1", "80.5", "", "", "", "", "80.8"]} -{"pcdb_id": 8135, "brand_name": "Alpha", "model_name": "CB24", "model_qualifier": "", "winter_efficiency_pct": 80.1, "summer_efficiency_pct": 70.0, "comparative_hot_water_efficiency_pct": 49.2, "output_kw_max": 23.3, "final_year_of_manufacture": 2005, "raw": ["008135", "000001", "0", "2011/Sep/06 13:08", "Alpha Therm", "Alpha", "CB24", "", "", "2000", "2005", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "23.3", "23.3", "", "", "80.1", "70.0", "", "49.2", "", "2", "", "", "104", "1", "2", "170", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.1", "80.5", "", "", "", "", "80.8"]} -{"pcdb_id": 8137, "brand_name": "Alpha", "model_name": "SY24", "model_qualifier": "", "winter_efficiency_pct": 80.3, "summer_efficiency_pct": 69.6, "comparative_hot_water_efficiency_pct": 50.9, "output_kw_max": 23.3, "final_year_of_manufacture": 2006, "raw": ["008137", "000001", "0", "2012/Mar/27 10:12", "Alpha Therm", "Alpha", "SY24", "", "", "2000", "2006", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "23.3", "23.3", "", "", "80.3", "69.6", "", "50.9", "", "2", "", "", "102", "1", "2", "170", "5", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.1", "80.5", "", "", "", "", "80.8"]} -{"pcdb_id": 8138, "brand_name": "Alpha", "model_name": "CB28", "model_qualifier": "", "winter_efficiency_pct": 81.0, "summer_efficiency_pct": 70.9, "comparative_hot_water_efficiency_pct": 49.8, "output_kw_max": 28.0, "final_year_of_manufacture": 2005, "raw": ["008138", "000001", "0", "2011/Sep/06 13:08", "Alpha Therm", "Alpha", "CB28", "", "", "2000", "2005", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "28.0", "28.0", "", "", "81.0", "70.9", "", "49.8", "", "2", "", "", "104", "1", "2", "170", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "83.3", "81.5", "", "", "", "", "81.8"]} -{"pcdb_id": 8140, "brand_name": "Powermax", "model_name": "155x", "model_qualifier": "", "winter_efficiency_pct": 84.3, "summer_efficiency_pct": 82.4, "comparative_hot_water_efficiency_pct": 66.4, "output_kw_max": 15.5, "final_year_of_manufacture": null, "raw": ["008140", "000099", "0", "2002/Aug/14 10:19", "Range Powermax", "Powermax", "155x", "", "87AU97", "1996", "current", "1", "1", "1", "3", "0", "", "", "1", "2", "2", "15.5", "15.5", "", "", "84.3", "82.4", "", "66.4", "", "2", "", "", "107", "1", "1", "140", "0", "3", "", "0", "100", "0", "50", "5", "80", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "83.8", "86.0", "", "", "", "", "85.6"]} -{"pcdb_id": 8147, "brand_name": "Ideal", "model_name": "Concord", "model_qualifier": "CXSD60", "winter_efficiency_pct": 78.7, "summer_efficiency_pct": 68.0, "comparative_hot_water_efficiency_pct": 49.7, "output_kw_max": 60.1, "final_year_of_manufacture": 2002, "raw": ["008147", "000008", "0", "2012/Mar/27 10:12", "Caradon Plumbing", "Ideal", "Concord", "CXSD60", "P.I.No 87/AQ/103", "", "2002", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "60.1", "60.1", "", "", "78.7", "68.0", "", "49.7", "", "2", "", "", "102", "1", "2", "10", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "80.7", "78.7", "", "", "", "", "79.1"]} -{"pcdb_id": 8148, "brand_name": "Ideal", "model_name": "Concord", "model_qualifier": "CXSD50", "winter_efficiency_pct": 77.2, "summer_efficiency_pct": 66.5, "comparative_hot_water_efficiency_pct": 48.6, "output_kw_max": 50.0, "final_year_of_manufacture": 2002, "raw": ["008148", "000008", "0", "2012/Mar/27 10:12", "Caradon Plumbing", "Ideal", "Concord", "CXSD50", "P.I.No 87/AQ/103", "", "2002", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "50.0", "50.0", "", "", "77.2", "66.5", "", "48.6", "", "2", "", "", "102", "1", "2", "10", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "79.5", "76.9", "", "", "", "", "77.4"]} -{"pcdb_id": 8149, "brand_name": "Ideal", "model_name": "Concord", "model_qualifier": "CXSD40", "winter_efficiency_pct": 77.2, "summer_efficiency_pct": 66.5, "comparative_hot_water_efficiency_pct": 48.5, "output_kw_max": 42.0, "final_year_of_manufacture": 2002, "raw": ["008149", "000008", "0", "2012/Mar/27 10:12", "Caradon Plumbing", "Ideal", "Concord", "CXSD40", "P.I.No 87/AQ/103", "", "2002", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "42.0", "42.0", "", "", "77.2", "66.5", "", "48.5", "", "2", "", "", "102", "1", "2", "10", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "79.2", "77.1", "", "", "", "", "77.5"]} -{"pcdb_id": 8156, "brand_name": "Ideal", "model_name": "Concord", "model_qualifier": "CXS60", "winter_efficiency_pct": 78.7, "summer_efficiency_pct": 68.0, "comparative_hot_water_efficiency_pct": 49.7, "output_kw_max": 60.1, "final_year_of_manufacture": 2002, "raw": ["008156", "000008", "0", "2012/Mar/27 10:12", "Caradon Plumbing", "Ideal", "Concord", "CXS60", "P.I.No 87/AQ/103", "", "2002", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "60.1", "60.1", "", "", "78.7", "68.0", "", "49.7", "", "2", "", "", "102", "1", "2", "10", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "80.7", "78.7", "", "", "", "", "79.1"]} -{"pcdb_id": 8157, "brand_name": "Ideal", "model_name": "Concord", "model_qualifier": "CXS50", "winter_efficiency_pct": 77.2, "summer_efficiency_pct": 66.5, "comparative_hot_water_efficiency_pct": 48.6, "output_kw_max": 50.0, "final_year_of_manufacture": 2002, "raw": ["008157", "000008", "0", "2012/Mar/27 10:12", "Caradon Plumbing", "Ideal", "Concord", "CXS50", "P.I.No 87/AQ/103", "", "2002", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "50.0", "50.0", "", "", "77.2", "66.5", "", "48.6", "", "2", "", "", "102", "1", "2", "10", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "79.5", "76.9", "", "", "", "", "77.4"]} -{"pcdb_id": 8158, "brand_name": "Ideal", "model_name": "Concord", "model_qualifier": "CXS40", "winter_efficiency_pct": 77.2, "summer_efficiency_pct": 66.5, "comparative_hot_water_efficiency_pct": 48.5, "output_kw_max": 42.0, "final_year_of_manufacture": 2002, "raw": ["008158", "000008", "0", "2012/Mar/27 10:12", "Caradon Plumbing", "Ideal", "Concord", "CXS40", "P.I.No 87/AQ/103", "", "2002", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "42.0", "42.0", "", "", "77.2", "66.5", "", "48.5", "", "2", "", "", "102", "1", "2", "10", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "79.2", "77.1", "", "", "", "", "77.5"]} -{"pcdb_id": 8165, "brand_name": "Ideal", "model_name": "Concord", "model_qualifier": "CXA60", "winter_efficiency_pct": 78.4, "summer_efficiency_pct": 68.3, "comparative_hot_water_efficiency_pct": 49.9, "output_kw_max": 60.1, "final_year_of_manufacture": 2002, "raw": ["008165", "000008", "0", "2012/Mar/27 10:12", "Caradon Plumbing", "Ideal", "Concord", "CXA60", "P.I.No 87/AP/80", "", "2002", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "60.1", "60.1", "", "", "78.4", "68.3", "", "49.9", "", "2", "", "", "101", "1", "1", "5", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "80.7", "79.3", "", "", "", "", "79.6"]} -{"pcdb_id": 8166, "brand_name": "Ideal", "model_name": "Concord", "model_qualifier": "CXA50", "winter_efficiency_pct": 77.3, "summer_efficiency_pct": 67.2, "comparative_hot_water_efficiency_pct": 49.1, "output_kw_max": 50.0, "final_year_of_manufacture": 2002, "raw": ["008166", "000008", "0", "2012/Mar/27 10:12", "Caradon Plumbing", "Ideal", "Concord", "CXA50", "P.I.No 87/AP/80", "", "2002", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "50", "50", "", "", "77.3", "67.2", "", "49.1", "", "2", "", "", "101", "1", "1", "5", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.5", "78.4", "", "", "", "", "78.6"]} -{"pcdb_id": 8167, "brand_name": "Ideal", "model_name": "Concord", "model_qualifier": "CXA40", "winter_efficiency_pct": 76.9, "summer_efficiency_pct": 66.8, "comparative_hot_water_efficiency_pct": 48.8, "output_kw_max": 42.0, "final_year_of_manufacture": 2002, "raw": ["008167", "000008", "0", "2012/Mar/27 10:12", "Caradon Plumbing", "Ideal", "Concord", "CXA40", "P.I.No 87/AP/80", "", "2002", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "42", "42", "", "", "76.9", "66.8", "", "48.8", "", "2", "", "", "101", "1", "1", "5", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.2", "77.8", "", "", "", "", "78.1"]} -{"pcdb_id": 8175, "brand_name": "Quantum", "model_name": "Q 100 LPG", "model_qualifier": "", "winter_efficiency_pct": 85.6, "summer_efficiency_pct": 78.0, "comparative_hot_water_efficiency_pct": 57.0, "output_kw_max": 33.7, "final_year_of_manufacture": null, "raw": ["008175", "000205", "0", "2012/Mar/27 10:12", "Quantum Heating", "Quantum", "Q 100 LPG", "", "", "1999", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "33.7", "33.7", "", "", "85.6", "78.0", "", "57.0", "", "2", "0", "", "101", "1", "1", "80", "80", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "89.0", "91.6", "", "", "", "", "91.1"]} -{"pcdb_id": 8176, "brand_name": "Quantum", "model_name": "Q 80 LPG", "model_qualifier": "", "winter_efficiency_pct": 85.0, "summer_efficiency_pct": 77.4, "comparative_hot_water_efficiency_pct": 56.5, "output_kw_max": 27.0, "final_year_of_manufacture": null, "raw": ["008176", "000205", "0", "2012/Mar/27 10:12", "Quantum Heating", "Quantum", "Q 80 LPG", "", "", "1999", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "27", "27", "", "", "85.0", "77.4", "", "56.5", "", "2", "0", "", "101", "1", "1", "80", "80", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.6", "89.0", "", "", "", "", "89.5"]} -{"pcdb_id": 8177, "brand_name": "Quantum", "model_name": "Q 60 LPG", "model_qualifier": "", "winter_efficiency_pct": 85.3, "summer_efficiency_pct": 77.7, "comparative_hot_water_efficiency_pct": 56.7, "output_kw_max": 20.2, "final_year_of_manufacture": null, "raw": ["008177", "000205", "0", "2012/Mar/27 10:12", "Quantum Heating", "Quantum", "Q 60 LPG", "", "", "1999", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "20.2", "20.2", "", "", "85.3", "77.7", "", "56.7", "", "2", "0", "", "101", "1", "1", "80", "80", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "88.3", "91.1", "", "", "", "", "90.6"]} -{"pcdb_id": 8178, "brand_name": "Quantum", "model_name": "Q50", "model_qualifier": "", "winter_efficiency_pct": 85.6, "summer_efficiency_pct": 78.0, "comparative_hot_water_efficiency_pct": 57.0, "output_kw_max": 16.8, "final_year_of_manufacture": null, "raw": ["008178", "000205", "0", "2012/Mar/27 10:12", "Quantum Heating", "Quantum", "Q50", "", "", "1999", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "16.8", "16.8", "", "", "85.6", "78.0", "", "57.0", "", "2", "", "", "101", "1", "1", "80", "80", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "92.8", "92.3", "", "", "", "", "92.4"]} -{"pcdb_id": 8179, "brand_name": "Viessmann", "model_name": "Vitodens 100", "model_qualifier": "WB10", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 24.0, "final_year_of_manufacture": 2005, "raw": ["008179", "000033", "0", "2012/Mar/27 10:12", "Viessmann", "Viessmann", "Vitodens 100", "WB10", "", "1999", "2005", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24", "24", "", "", "88.8", "79.8", "", "58.3", "", "2", "", "", "102", "1", "2", "50", "10", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "98.8", "", "", "", "", "96.7"]} -{"pcdb_id": 8180, "brand_name": "Viessmann", "model_name": "Vitodens 100", "model_qualifier": "WB14", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 56.4, "output_kw_max": 24.0, "final_year_of_manufacture": 2005, "raw": ["008180", "000033", "0", "2006/Jan/17 12:55", "Viessmann", "Viessmann", "Vitodens 100", "WB14", "", "1999", "2005", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "88.8", "80.2", "", "56.4", "", "2", "", "", "104", "1", "2", "50", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "98.8", "", "", "", "", "96.7"]} -{"pcdb_id": 8182, "brand_name": "Worcester", "model_name": "24CDi", "model_qualifier": "RSF Serial ASB", "winter_efficiency_pct": 79.0, "summer_efficiency_pct": 68.9, "comparative_hot_water_efficiency_pct": 48.5, "output_kw_max": 24.0, "final_year_of_manufacture": 2001, "raw": ["008182", "000035", "0", "2002/Jul/29 15:33", "Worcester Heat Systems", "Worcester", "24CDi", "RSF Serial ASB", "47 311 30", "1997", "2001", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "24", "24", "", "", "79.0", "68.9", "", "48.5", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.4", "78.1", "", "", "", "", "78.9"]} -{"pcdb_id": 8183, "brand_name": "Worcester", "model_name": "24CDi", "model_qualifier": "RSF Serial ASC", "winter_efficiency_pct": 81.4, "summer_efficiency_pct": 71.3, "comparative_hot_water_efficiency_pct": 50.2, "output_kw_max": 24.0, "final_year_of_manufacture": 2001, "raw": ["008183", "000035", "0", "2002/Feb/26 12:02", "Worcester Heat Systems", "Worcester", "24CDi", "RSF Serial ASC", "47 311 31", "1997", "2001", "2", "2", "1", "2", "0", "", "", "1", "2", "2", "24", "24", "", "", "81.4", "71.3", "", "50.2", "", "2", "0", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "84.8", "80.5", "", "", "", "", "81.3"]} -{"pcdb_id": 8184, "brand_name": "Halstead", "model_name": "Ace", "model_qualifier": "", "winter_efficiency_pct": 77.1, "summer_efficiency_pct": 67.0, "comparative_hot_water_efficiency_pct": 47.1, "output_kw_max": 24.0, "final_year_of_manufacture": 2001, "raw": ["008184", "000019", "0", "2006/Jan/17 12:55", "Halstead Boilers", "Halstead", "Ace", "", "Gc No 47 333 10", "", "2001", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "24", "24", "", "", "77.1", "67.0", "", "47.1", "", "2", "", "", "104", "1", "2", "140", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "80.1", "76.4", "", "", "", "", "77.1"]} -{"pcdb_id": 8185, "brand_name": "Grant", "model_name": "Euroflame", "model_qualifier": "Kitchen / Utility 70-90", "winter_efficiency_pct": 85.8, "summer_efficiency_pct": 74.1, "comparative_hot_water_efficiency_pct": 54.1, "output_kw_max": 26.4, "final_year_of_manufacture": null, "raw": ["008185", "000048", "0", "2012/Mar/27 10:12", "Grant Engineering", "Grant", "Euroflame", "Kitchen / Utility 70-90", "", "1993", "current", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "20.5", "26.4", "", "", "85.8", "74.1", "", "54.1", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.3", "86.3", "", "", "", "", "86.1"]} -{"pcdb_id": 8186, "brand_name": "Grant", "model_name": "Euroflame", "model_qualifier": "Boilerhouse 70-90", "winter_efficiency_pct": 85.8, "summer_efficiency_pct": 74.1, "comparative_hot_water_efficiency_pct": 54.1, "output_kw_max": 26.4, "final_year_of_manufacture": null, "raw": ["008186", "000048", "0", "2012/Mar/27 10:12", "Grant Engineering", "Grant", "Euroflame", "Boilerhouse 70-90", "", "1993", "current", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "20.5", "26.4", "", "", "85.8", "74.1", "", "54.1", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.3", "86.3", "", "", "", "", "86.1"]} -{"pcdb_id": 8187, "brand_name": "Grant", "model_name": "Euroflame", "model_qualifier": "Outdoor Module 70-90", "winter_efficiency_pct": 85.8, "summer_efficiency_pct": 74.1, "comparative_hot_water_efficiency_pct": 54.1, "output_kw_max": 26.4, "final_year_of_manufacture": null, "raw": ["008187", "000048", "0", "2012/Mar/27 10:12", "Grant Engineering", "Grant", "Euroflame", "Outdoor Module 70-90", "", "1993", "current", "4", "1", "2", "1", "0", "", "", "1", "1", "2", "20.5", "26.4", "", "", "85.8", "74.1", "", "54.1", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.3", "86.3", "", "", "", "", "86.1"]} -{"pcdb_id": 8188, "brand_name": "Grant", "model_name": "Euroflame", "model_qualifier": "Boilerhouse 50-70", "winter_efficiency_pct": 85.8, "summer_efficiency_pct": 74.1, "comparative_hot_water_efficiency_pct": 54.1, "output_kw_max": 20.5, "final_year_of_manufacture": null, "raw": ["008188", "000048", "0", "2012/Mar/27 10:12", "Grant Engineering", "Grant", "Euroflame", "Boilerhouse 50-70", "", "1996", "current", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "14.6", "20.5", "", "", "85.8", "74.1", "", "54.1", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.3", "86.3", "", "", "", "", "86.1"]} -{"pcdb_id": 8189, "brand_name": "Grant", "model_name": "Euroflame", "model_qualifier": "Kitchen / Utility 50-70", "winter_efficiency_pct": 85.8, "summer_efficiency_pct": 74.1, "comparative_hot_water_efficiency_pct": 54.1, "output_kw_max": 20.5, "final_year_of_manufacture": null, "raw": ["008189", "000048", "0", "2012/Mar/27 10:12", "Grant Engineering", "Grant", "Euroflame", "Kitchen / Utility 50-70", "", "1997", "current", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "14.65", "20.5", "", "", "85.8", "74.1", "", "54.1", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.3", "86.3", "", "", "", "", "86.1"]} -{"pcdb_id": 8190, "brand_name": "Grant", "model_name": "Euroflame", "model_qualifier": "Outdoor Module 50-70", "winter_efficiency_pct": 85.8, "summer_efficiency_pct": 74.1, "comparative_hot_water_efficiency_pct": 54.1, "output_kw_max": 20.5, "final_year_of_manufacture": null, "raw": ["008190", "000048", "0", "2012/Mar/27 10:12", "Grant Engineering", "Grant", "Euroflame", "Outdoor Module 50-70", "", "1996", "current", "4", "1", "2", "1", "0", "", "", "1", "1", "2", "14.65", "20.5", "", "", "85.8", "74.1", "", "54.1", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.3", "86.3", "", "", "", "", "86.1"]} -{"pcdb_id": 8191, "brand_name": "Grant", "model_name": "Euroflame", "model_qualifier": "System 50-90", "winter_efficiency_pct": 85.8, "summer_efficiency_pct": 74.1, "comparative_hot_water_efficiency_pct": 54.1, "output_kw_max": 26.4, "final_year_of_manufacture": null, "raw": ["008191", "000048", "0", "2012/Mar/27 10:12", "Grant Engineering", "Grant", "Euroflame", "System 50-90", "", "1998", "current", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "14.65", "26.4", "", "", "85.8", "74.1", "", "54.1", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.3", "86.3", "", "", "", "", "86.1"]} -{"pcdb_id": 8192, "brand_name": "Grant", "model_name": "Combi", "model_qualifier": "70 Mk II", "winter_efficiency_pct": 84.0, "summer_efficiency_pct": 74.5, "comparative_hot_water_efficiency_pct": 52.4, "output_kw_max": 20.52, "final_year_of_manufacture": null, "raw": ["008192", "000048", "0", "2001/Jun/19 15:49", "Grant Engineering", "Grant", "Combi", "70 Mk II", "", "1997", "current", "4", "1", "1", "2", "0", "", "", "1", "2", "2", "20.52", "20.52", "", "", "84.0", "74.5", "", "52.4", "", "2", "", "", "202", "1", "1", "", "", "0", "", "", "0", "0", "25", "3", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.3", "86.3", "", "", "", "", "86.1"]} -{"pcdb_id": 8193, "brand_name": "Grant", "model_name": "Combi", "model_qualifier": "90 Mk II", "winter_efficiency_pct": 84.9, "summer_efficiency_pct": 75.4, "comparative_hot_water_efficiency_pct": 53.0, "output_kw_max": 26.37, "final_year_of_manufacture": null, "raw": ["008193", "000048", "0", "2001/Jun/19 15:48", "Grant Engineering", "Grant", "Combi", "90 Mk II", "", "1995", "current", "4", "1", "1", "2", "0", "", "", "1", "2", "2", "26.37", "26.37", "", "", "84.9", "75.4", "", "53.0", "", "2", "", "", "202", "1", "1", "", "", "0", "", "", "0", "0", "25", "3", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.4", "88.0", "", "", "", "", "87.7"]} -{"pcdb_id": 8194, "brand_name": "Grant", "model_name": "Multipass", "model_qualifier": "Boilerhouse 70-90", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 26.37, "final_year_of_manufacture": null, "raw": ["008194", "000048", "0", "2012/Mar/27 10:12", "Grant Engineering", "Grant", "Multipass", "Boilerhouse 70-90", "", "1994", "current", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "20.52", "26.37", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "89.8", "87.3", "", "", "", "", "87.8"]} -{"pcdb_id": 8195, "brand_name": "Grant", "model_name": "Multipass", "model_qualifier": "Boilerhouse 90-110", "winter_efficiency_pct": 86.5, "summer_efficiency_pct": 74.8, "comparative_hot_water_efficiency_pct": 54.6, "output_kw_max": 32.24, "final_year_of_manufacture": null, "raw": ["008195", "000048", "0", "2012/Mar/27 10:12", "Grant Engineering", "Grant", "Multipass", "Boilerhouse 90-110", "", "1994", "current", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "26.37", "32.24", "", "", "86.5", "74.8", "", "54.6", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "91.1", "86.8", "", "", "", "", "87.6"]} -{"pcdb_id": 8196, "brand_name": "Grant", "model_name": "Multipass", "model_qualifier": "Boilerhouse 110-140", "winter_efficiency_pct": 86.5, "summer_efficiency_pct": 74.8, "comparative_hot_water_efficiency_pct": 54.6, "output_kw_max": 41.0, "final_year_of_manufacture": null, "raw": ["008196", "000048", "0", "2012/Mar/27 10:12", "Grant Engineering", "Grant", "Multipass", "Boilerhouse 110-140", "", "1994", "current", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "32.24", "41.0", "", "", "86.5", "74.8", "", "54.6", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "91.1", "86.8", "", "", "", "", "87.6"]} -{"pcdb_id": 8197, "brand_name": "Grant", "model_name": "Multipass", "model_qualifier": "Boilerhouse 140-160", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 46.89, "final_year_of_manufacture": null, "raw": ["008197", "000048", "0", "2012/Mar/27 10:12", "Grant Engineering", "Grant", "Multipass", "Boilerhouse 140-160", "", "1995", "current", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "41.03", "46.89", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "88.0", "90.9", "", "", "", "", "90.3"]} -{"pcdb_id": 8198, "brand_name": "Grant", "model_name": "Multipass", "model_qualifier": "Boilerhouse 160-200", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 58.62, "final_year_of_manufacture": null, "raw": ["008198", "000048", "0", "2012/Mar/27 10:12", "Grant Engineering", "Grant", "Multipass", "Boilerhouse 160-200", "", "1995", "current", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "46.89", "58.62", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "90.1", "93.5", "", "", "", "", "92.9"]} -{"pcdb_id": 8199, "brand_name": "Grant", "model_name": "Multipass", "model_qualifier": "Kitchen 50-70", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 20.5, "final_year_of_manufacture": null, "raw": ["008199", "000048", "0", "2012/Mar/27 10:12", "Grant Engineering", "Grant", "Multipass", "Kitchen 50-70", "", "1994", "current", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "14.6", "20.5", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "90.0", "87.6", "", "", "", "", "88.1"]} -{"pcdb_id": 8200, "brand_name": "Grant", "model_name": "Multipass", "model_qualifier": "Kitchen 70-90", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 26.37, "final_year_of_manufacture": null, "raw": ["008200", "000048", "0", "2012/Mar/27 10:12", "Grant Engineering", "Grant", "Multipass", "Kitchen 70-90", "", "1994", "current", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "20.52", "26.37", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "89.8", "87.3", "", "", "", "", "87.8"]} -{"pcdb_id": 8201, "brand_name": "Grant", "model_name": "Multipass", "model_qualifier": "Kitchen 90-110", "winter_efficiency_pct": 86.5, "summer_efficiency_pct": 74.8, "comparative_hot_water_efficiency_pct": 54.7, "output_kw_max": 41.03, "final_year_of_manufacture": null, "raw": ["008201", "000048", "0", "2012/Mar/27 10:12", "Grant Engineering", "Grant", "Multipass", "Kitchen 90-110", "", "1995", "current", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "26.37", "41.03", "", "", "86.5", "74.8", "", "54.7", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.9", "86.9", "", "", "", "", "87.1"]} -{"pcdb_id": 8202, "brand_name": "Grant", "model_name": "Multipass", "model_qualifier": "Kitchen 110-140", "winter_efficiency_pct": 86.5, "summer_efficiency_pct": 74.8, "comparative_hot_water_efficiency_pct": 54.6, "output_kw_max": 41.03, "final_year_of_manufacture": null, "raw": ["008202", "000048", "0", "2012/Mar/27 10:12", "Grant Engineering", "Grant", "Multipass", "Kitchen 110-140", "", "1995", "current", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "32.24", "41.03", "", "", "86.5", "74.8", "", "54.6", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "91.1", "86.8", "", "", "", "", "87.6"]} -{"pcdb_id": 8203, "brand_name": "Grant", "model_name": "Multipass", "model_qualifier": "Kitchen 140-160", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 46.89, "final_year_of_manufacture": null, "raw": ["008203", "000048", "0", "2012/Mar/27 10:12", "Grant Engineering", "Grant", "Multipass", "Kitchen 140-160", "", "1995", "current", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "41.03", "46.89", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "88.0", "90.9", "", "", "", "", "90.3"]} -{"pcdb_id": 8204, "brand_name": "Grant", "model_name": "Multipass", "model_qualifier": "Kitchen 160-200", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 58.6, "final_year_of_manufacture": null, "raw": ["008204", "000048", "0", "2012/Mar/27 10:12", "Grant Engineering", "Grant", "Multipass", "Kitchen 160-200", "", "1995", "current", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "46.9", "58.6", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "93.5", "90.1", "", "", "", "", "90.8"]} -{"pcdb_id": 8205, "brand_name": "Worcester", "model_name": "24 CBi", "model_qualifier": "RSF", "winter_efficiency_pct": 77.8, "summer_efficiency_pct": 67.7, "comparative_hot_water_efficiency_pct": 49.4, "output_kw_max": 23.4, "final_year_of_manufacture": 2001, "raw": ["008205", "000035", "0", "2012/Mar/27 10:12", "Worcester Heat Systems", "Worcester", "24 CBi", "RSF", "41 311 48", "2000", "2001", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "14.7", "23.4", "", "", "77.8", "67.7", "", "49.4", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.8", "76.0", "", "", "", "", "77.3"]} -{"pcdb_id": 8206, "brand_name": "Worcester", "model_name": "15 CBi", "model_qualifier": "RSF", "winter_efficiency_pct": 77.5, "summer_efficiency_pct": 67.4, "comparative_hot_water_efficiency_pct": 49.2, "output_kw_max": 14.7, "final_year_of_manufacture": 2001, "raw": ["008206", "000035", "0", "2012/Mar/27 10:12", "Worcester Heat Systems", "Worcester", "15 CBi", "RSF", "41 311 47", "2000", "2001", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "9.0", "14.7", "", "", "77.5", "67.4", "", "49.2", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.7", "76.4", "", "", "", "", "77.4"]} -{"pcdb_id": 8207, "brand_name": "Halstead", "model_name": "Wickes Ace", "model_qualifier": "", "winter_efficiency_pct": 77.1, "summer_efficiency_pct": 67.0, "comparative_hot_water_efficiency_pct": 47.1, "output_kw_max": 24.0, "final_year_of_manufacture": 2001, "raw": ["008207", "000019", "0", "2006/Jan/17 12:55", "Halstead Boilers", "Halstead", "Wickes Ace", "", "Gc No 47 333 11", "", "2001", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "24", "24", "", "", "77.1", "67.0", "", "47.1", "", "2", "", "", "104", "1", "2", "140", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "80.1", "76.4", "", "", "", "", "77.1"]} -{"pcdb_id": 8208, "brand_name": "Benson Heating", "model_name": "Halstead", "model_qualifier": "Jetstreme 55", "winter_efficiency_pct": 85.3, "summer_efficiency_pct": 73.6, "comparative_hot_water_efficiency_pct": 53.7, "output_kw_max": 16.1, "final_year_of_manufacture": 2003, "raw": ["008208", "000019", "0", "2012/Mar/27 10:12", "Benson Heating", "Benson Heating", "Halstead", "Jetstreme 55", "08/07/7506-2OFB", "1998", "2003", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "13.2", "16.1", "", "", "85.3", "73.6", "", "53.7", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "88.3", "84.3", "", "", "", "", "85.1"]} -{"pcdb_id": 8209, "brand_name": "Benson Heating", "model_name": "Halstead", "model_qualifier": "Jetstreme 80", "winter_efficiency_pct": 83.8, "summer_efficiency_pct": 72.1, "comparative_hot_water_efficiency_pct": 52.6, "output_kw_max": 23.4, "final_year_of_manufacture": 2003, "raw": ["008209", "000019", "0", "2012/Mar/27 10:12", "Benson Heating", "Benson Heating", "Halstead", "Jetstreme 80", "06/97/7506OFB", "1997", "2003", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "17.6", "23.4", "", "", "83.8", "72.1", "", "52.6", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "84.7", "82.8", "", "", "", "", "83.2"]} -{"pcdb_id": 8210, "brand_name": "Benson Heating", "model_name": "Halstead", "model_qualifier": "Jetstreme 125", "winter_efficiency_pct": 83.3, "summer_efficiency_pct": 71.6, "comparative_hot_water_efficiency_pct": 52.3, "output_kw_max": 36.6, "final_year_of_manufacture": 2003, "raw": ["008210", "000019", "0", "2012/Mar/27 10:12", "Benson Heating", "Benson Heating", "Halstead", "Jetstreme 125", "04/98/7506-3OFB", "1998", "2003", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "26.4", "36.6", "", "", "83.3", "71.6", "", "52.3", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "83.0", "83.6", "", "", "", "", "83.5"]} -{"pcdb_id": 8211, "brand_name": "Warmworld", "model_name": "FFC 65/80", "model_qualifier": "", "winter_efficiency_pct": 84.0, "summer_efficiency_pct": 76.4, "comparative_hot_water_efficiency_pct": 55.8, "output_kw_max": 23.5, "final_year_of_manufacture": null, "raw": ["008211", "000034", "0", "2012/Mar/27 10:12", "Warmworld", "Warmworld", "FFC 65/80", "", "GC No 41.555.16", "2000", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "20.6", "23.5", "", "", "84.0", "76.4", "", "55.8", "", "2", "", "", "101", "1", "1", "40", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "87.8", "90.2", "", "", "", "", "89.7"]} -{"pcdb_id": 8212, "brand_name": "Warmworld", "model_name": "FFC 30/60", "model_qualifier": "", "winter_efficiency_pct": 84.7, "summer_efficiency_pct": 77.1, "comparative_hot_water_efficiency_pct": 56.3, "output_kw_max": 17.0, "final_year_of_manufacture": null, "raw": ["008212", "000034", "0", "2012/Mar/27 10:12", "Warmworld", "Warmworld", "FFC 30/60", "", "GC No 41.555.15", "2000", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "10.3", "17.0", "", "", "84.7", "77.1", "", "56.3", "", "2", "", "", "101", "1", "1", "40", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "87.8", "92.1", "", "", "", "", "91.3"]} -{"pcdb_id": 8213, "brand_name": "Ariston", "model_name": "Microgenus 27 MFFI", "model_qualifier": "", "winter_efficiency_pct": 81.1, "summer_efficiency_pct": 71.0, "comparative_hot_water_efficiency_pct": 49.9, "output_kw_max": 27.8, "final_year_of_manufacture": 2007, "raw": ["008213", "000080", "0", "2007/Sep/12 15:03", "Merloni TermoSanitari SpA", "Ariston", "Microgenus 27 MFFI", "", "GC No. 47-116-15", "1999", "2007", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "27.8", "27.8", "", "", "81.1", "71.0", "", "49.9", "", "2", "", "", "104", "1", "2", "130", "7", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "84.2", "81.7", "", "", "", "", "82.2"]} -{"pcdb_id": 8214, "brand_name": "Ariston", "model_name": "Microgenus 23 MFFI", "model_qualifier": "", "winter_efficiency_pct": 81.3, "summer_efficiency_pct": 71.2, "comparative_hot_water_efficiency_pct": 50.1, "output_kw_max": 23.8, "final_year_of_manufacture": 2007, "raw": ["008214", "000080", "0", "2007/Sep/12 15:00", "Merloni TermoSanitari SpA", "Ariston", "Microgenus 23 MFFI", "", "GC No. 47-116-14", "1999", "2007", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "23.8", "23.8", "", "", "81.3", "71.2", "", "50.1", "", "2", "", "", "104", "1", "2", "130", "7", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "83.7", "82.1", "", "", "", "", "82.4"]} -{"pcdb_id": 8215, "brand_name": "Ariston", "model_name": "Microcombi 23 MFFI", "model_qualifier": "", "winter_efficiency_pct": 81.0, "summer_efficiency_pct": 70.9, "comparative_hot_water_efficiency_pct": 49.9, "output_kw_max": 23.8, "final_year_of_manufacture": 2007, "raw": ["008215", "000080", "0", "2007/Jun/18 09:30", "Merloni TermoSanitari SpA", "Ariston", "Microcombi 23 MFFI", "", "GC No. 47-116-16", "2000", "2007", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "23.8", "23.8", "", "", "81.0", "70.9", "", "49.9", "", "2", "", "", "104", "1", "2", "130", "7", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "83.3", "81.5", "", "", "", "", "81.9"]} -{"pcdb_id": 8216, "brand_name": "Ariston", "model_name": "Genus 27 BFFI Plus", "model_qualifier": "", "winter_efficiency_pct": 78.9, "summer_efficiency_pct": 69.8, "comparative_hot_water_efficiency_pct": 36.9, "output_kw_max": 27.4, "final_year_of_manufacture": 2002, "raw": ["008216", "000080", "0", "2024/Jan/31 10:17", "Merloni TermoSanitari SpA", "Ariston", "Genus 27 BFFI Plus", "", "GC No. 47-116-11", "1997", "2002", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "27.4", "27.4", "", "", "78.9", "69.8", "", "36.9", "", "2", "", "", "106", "1", "2", "200", "7", "2", "2", "0", "52", "0", "15", "2", "62", "60", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.4", "77.6", "", "", "", "", "78.3"]} -{"pcdb_id": 8217, "brand_name": "Ariston", "model_name": "Eurocombi A/27 MFFI", "model_qualifier": "", "winter_efficiency_pct": 79.8, "summer_efficiency_pct": 69.7, "comparative_hot_water_efficiency_pct": 49.0, "output_kw_max": 27.3, "final_year_of_manufacture": 2003, "raw": ["008217", "000080", "0", "2006/Jan/17 12:55", "Merloni TermoSanitari SpA", "Ariston", "Eurocombi A/27 MFFI", "", "GC No. 47-116-12", "1999", "2003", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "27.3", "27.3", "", "", "79.8", "69.7", "", "49.0", "", "2", "", "", "104", "1", "2", "190", "7", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.5", "79.6", "", "", "", "", "80.1"]} -{"pcdb_id": 8218, "brand_name": "Ariston", "model_name": "Eurocombi A/23 MFFI", "model_qualifier": "", "winter_efficiency_pct": 79.0, "summer_efficiency_pct": 68.9, "comparative_hot_water_efficiency_pct": 48.4, "output_kw_max": 23.1, "final_year_of_manufacture": 2003, "raw": ["008218", "000080", "0", "2006/Jan/17 12:55", "Merloni TermoSanitari SpA", "Ariston", "Eurocombi A/23 MFFI", "", "GC No. 47-116-10", "1999", "2003", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "23.1", "23.1", "", "", "79.0", "68.9", "", "48.4", "", "2", "", "", "104", "1", "2", "150", "7", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.3", "79.1", "", "", "", "", "79.5"]} -{"pcdb_id": 8219, "brand_name": "Ariston", "model_name": "Genus 30 MFFI", "model_qualifier": "", "winter_efficiency_pct": 80.2, "summer_efficiency_pct": 70.1, "comparative_hot_water_efficiency_pct": 49.3, "output_kw_max": 30.3, "final_year_of_manufacture": 2007, "raw": ["008219", "000080", "0", "2007/Sep/12 15:08", "Merloni TermoSanitari SpA", "Ariston", "Genus 30 MFFI", "", "GC No. 47-116-13", "1999", "2007", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "30.3", "30.3", "", "", "80.2", "70.1", "", "49.3", "", "2", "", "", "104", "1", "2", "190", "7", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.9", "79.8", "", "", "", "", "80.4"]} -{"pcdb_id": 8220, "brand_name": "Ariston", "model_name": "Microsystem 10 RFFI", "model_qualifier": "", "winter_efficiency_pct": 79.1, "summer_efficiency_pct": 69.0, "comparative_hot_water_efficiency_pct": 50.4, "output_kw_max": 10.4, "final_year_of_manufacture": 2007, "raw": ["008220", "000080", "0", "2012/Mar/27 10:12", "Merloni TermoSanitari SpA", "Ariston", "Microsystem 10 RFFI", "", "GC No. 41-116-04", "2000", "2007", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "10.4", "10.4", "", "", "79.1", "69.0", "", "50.4", "", "2", "", "", "101", "1", "1", "155", "7", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.7", "79.6", "", "", "", "", "80.0"]} -{"pcdb_id": 8221, "brand_name": "Ariston", "model_name": "Microsystem 15 RFFI", "model_qualifier": "", "winter_efficiency_pct": 80.9, "summer_efficiency_pct": 70.8, "comparative_hot_water_efficiency_pct": 51.7, "output_kw_max": 13.8, "final_year_of_manufacture": 2007, "raw": ["008221", "000080", "0", "2012/Mar/27 10:12", "Merloni TermoSanitari SpA", "Ariston", "Microsystem 15 RFFI", "", "GC No. 41-116-05", "2000", "2007", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "13.8", "13.8", "", "", "80.9", "70.8", "", "51.7", "", "2", "", "", "101", "1", "1", "155", "7", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.8", "82.2", "", "", "", "", "82.3"]} -{"pcdb_id": 8222, "brand_name": "Ariston", "model_name": "Microsystem 21 RFFI", "model_qualifier": "", "winter_efficiency_pct": 81.4, "summer_efficiency_pct": 70.7, "comparative_hot_water_efficiency_pct": 51.6, "output_kw_max": 21.0, "final_year_of_manufacture": 2007, "raw": ["008222", "000080", "0", "2012/Mar/27 10:12", "Merloni TermoSanitari SpA", "Ariston", "Microsystem 21 RFFI", "", "GC No. 41-116-06", "2000", "2007", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "21.0", "21.0", "", "", "81.4", "70.7", "", "51.6", "", "2", "", "", "102", "1", "2", "155", "7", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "83.6", "81.8", "", "", "", "", "82.2"]} -{"pcdb_id": 8223, "brand_name": "Ariston", "model_name": "Ecogenus 24 MFFI", "model_qualifier": "", "winter_efficiency_pct": 86.6, "summer_efficiency_pct": 78.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 24.5, "final_year_of_manufacture": 2002, "raw": ["008223", "000080", "0", "2006/Jan/17 12:55", "Merloni TermoSanitari SpA", "Ariston", "Ecogenus 24 MFFI", "", "GC No. 47-116-17", "2000", "2002", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.5", "24.5", "", "", "86.6", "78.0", "", "54.8", "", "2", "", "", "104", "1", "2", "130", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.7", "93.3", "", "", "", "", "92.3"]} -{"pcdb_id": 8224, "brand_name": "Ariston", "model_name": "Ecogenus 24 RFFI System", "model_qualifier": "", "winter_efficiency_pct": 86.6, "summer_efficiency_pct": 77.6, "comparative_hot_water_efficiency_pct": 56.7, "output_kw_max": 24.5, "final_year_of_manufacture": 2002, "raw": ["008224", "000080", "0", "2012/Mar/27 10:12", "Merloni TermoSanitari SpA", "Ariston", "Ecogenus 24 RFFI System", "", "GC No. 41-116-03", "2000", "2002", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24.5", "24.5", "", "", "86.6", "77.6", "", "56.7", "", "2", "", "", "102", "1", "2", "130", "7", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.7", "93.3", "", "", "", "", "92.3"]} -{"pcdb_id": 8225, "brand_name": "Ariston", "model_name": "Genus 27 RFFI System", "model_qualifier": "", "winter_efficiency_pct": 80.0, "summer_efficiency_pct": 69.3, "comparative_hot_water_efficiency_pct": 50.7, "output_kw_max": 27.3, "final_year_of_manufacture": 2007, "raw": ["008225", "000080", "0", "2012/Mar/27 10:12", "Merloni TermoSanitari SpA", "Ariston", "Genus 27 RFFI System", "", "GC No. 41-116-01", "1998", "2007", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "27.3", "27.3", "", "", "80.0", "69.3", "", "50.7", "", "2", "", "", "102", "1", "2", "149", "7", "0", "", "0", "0", "0", "0", "", "0", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.5", "79.6", "", "", "", "", "80.1"]} -{"pcdb_id": 8226, "brand_name": "Worcester", "model_name": "Danesmoor WM 12/19", "model_qualifier": "RS", "winter_efficiency_pct": 85.2, "summer_efficiency_pct": 73.5, "comparative_hot_water_efficiency_pct": 53.7, "output_kw_max": 19.0, "final_year_of_manufacture": 2002, "raw": ["008226", "000035", "0", "2020/Sep/02 14:14", "Worcester Heat Systems", "Worcester", "Danesmoor WM 12/19", "RS", "C15661/1", "2000", "2002", "4", "2", "2", "1", "0", "", "", "1", "2", "1", "12", "19.0", "", "", "85.2", "73.5", "", "53.7", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "84.4", "86.0", "", "", "", "", "85.7"]} -{"pcdb_id": 8227, "brand_name": "Ferroli", "model_name": "Modena 102", "model_qualifier": "", "winter_efficiency_pct": 78.9, "summer_efficiency_pct": 68.8, "comparative_hot_water_efficiency_pct": 48.4, "output_kw_max": 30.0, "final_year_of_manufacture": 2005, "raw": ["008227", "000097", "0", "2009/Apr/28 16:13", "Ferroli", "Ferroli", "Modena 102", "", "", "1999", "2005", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "30.0", "30.0", "", "", "78.9", "68.8", "", "48.4", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.5", "78.7", "", "", "", "", "79.2"]} -{"pcdb_id": 8228, "brand_name": "Ferroli", "model_name": "Arena 30 A", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 32.4, "final_year_of_manufacture": 2001, "raw": ["008228", "000097", "0", "2012/Mar/27 10:12", "Ferroli SpA", "Ferroli", "Arena 30 A", "", "", "2000", "2001", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "32.4", "32.4", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.5", "97.0", "", "", "", "", "95.2"]} -{"pcdb_id": 8229, "brand_name": "Ferroli", "model_name": "Arena 30 C", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 55.8, "output_kw_max": 32.4, "final_year_of_manufacture": 2001, "raw": ["008229", "000097", "0", "2006/Jan/17 12:55", "Ferroli SpA", "Ferroli", "Arena 30 C", "", "", "2000", "2001", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "32.4", "32.4", "", "", "88.0", "79.4", "", "55.8", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.5", "97.0", "", "", "", "", "95.2"]} -{"pcdb_id": 8230, "brand_name": "Servowarm", "model_name": "Elite 21 Plus", "model_qualifier": "", "winter_efficiency_pct": 84.7, "summer_efficiency_pct": 77.1, "comparative_hot_water_efficiency_pct": 56.3, "output_kw_max": 17.0, "final_year_of_manufacture": null, "raw": ["008230", "000091", "0", "2012/Mar/27 10:12", "Malvern Boilers", "Servowarm", "Elite 21 Plus", "", "GC No 41.555.13", "2000", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "10.3", "17", "", "", "84.7", "77.1", "", "56.3", "", "2", "", "", "101", "1", "1", "40", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "87.8", "92.1", "", "", "", "", "91.3"]} -{"pcdb_id": 8231, "brand_name": "Servowarm", "model_name": "Elite 21", "model_qualifier": "", "winter_efficiency_pct": 84.0, "summer_efficiency_pct": 76.4, "comparative_hot_water_efficiency_pct": 55.8, "output_kw_max": 23.5, "final_year_of_manufacture": null, "raw": ["008231", "000091", "0", "2012/Mar/27 10:12", "Malvern Boilers", "Servowarm", "Elite 21", "", "GC No 41.555.14", "2000", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "20.6", "23.5", "", "", "84.0", "76.4", "", "55.8", "", "2", "", "", "101", "1", "1", "40", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "87.8", "90.2", "", "", "", "", "89.7"]} -{"pcdb_id": 8232, "brand_name": "Keston", "model_name": "Celsius", "model_qualifier": "25", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 25.0, "final_year_of_manufacture": null, "raw": ["008232", "000022", "0", "2012/Mar/27 10:12", "Keston Boilers", "Keston", "Celsius", "25", "Celsius 25", "2000", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "25.0", "25.0", "", "", "88.2", "79.2", "", "57.8", "", "2", "", "", "102", "1", "2", "0", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.5", "97.0", "", "", "", "", "95.4"]} -{"pcdb_id": 8233, "brand_name": "Eco Hometec (UK)", "model_name": "Multi-Oil", "model_qualifier": "Type 4", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 78.9, "comparative_hot_water_efficiency_pct": 57.6, "output_kw_max": 20.0, "final_year_of_manufacture": 2005, "raw": ["008233", "000014", "0", "2012/Mar/27 10:12", "VTH-AG", "Eco Hometec (UK)", "Multi-Oil", "Type 4", "", "1998", "2005", "4", "2", "1", "1", "0", "", "", "2", "2", "2", "20", "20", "", "", "86.7", "78.9", "", "57.6", "", "2", "", "", "201", "1", "2", "60", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "91.1", "91.3", "", "", "", "", "91.2"]} -{"pcdb_id": 8234, "brand_name": "Eco Hometec (UK)", "model_name": "Multi-Oil", "model_qualifier": "Type 2.1", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 78.9, "comparative_hot_water_efficiency_pct": 57.6, "output_kw_max": 20.0, "final_year_of_manufacture": 2005, "raw": ["008234", "000014", "0", "2012/Mar/27 10:12", "VTH-AG", "Eco Hometec (UK)", "Multi-Oil", "Type 2.1", "", "1998", "2005", "4", "2", "1", "1", "0", "", "", "2", "2", "2", "10", "20", "", "", "86.7", "78.9", "", "57.6", "", "2", "", "", "201", "1", "1", "60", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.1", "91.3", "", "", "", "", "91.2"]} -{"pcdb_id": 8239, "brand_name": "Biasi", "model_name": "24S", "model_qualifier": "", "winter_efficiency_pct": 79.2, "summer_efficiency_pct": 69.1, "comparative_hot_water_efficiency_pct": 48.6, "output_kw_max": 24.0, "final_year_of_manufacture": 2002, "raw": ["008239", "000208", "0", "2006/Jan/17 12:55", "Biasi (UK)", "Biasi", "24S", "", "47-970-06", "1998", "2002", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "24", "24", "", "", "79.2", "69.1", "", "48.6", "", "2", "", "", "104", "1", "2", "170", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.7", "79.0", "", "", "", "", "79.5"]} -{"pcdb_id": 8240, "brand_name": "Biasi", "model_name": "24SR", "model_qualifier": "", "winter_efficiency_pct": 79.4, "summer_efficiency_pct": 68.7, "comparative_hot_water_efficiency_pct": 50.2, "output_kw_max": 24.0, "final_year_of_manufacture": 2002, "raw": ["008240", "000208", "0", "2012/Mar/27 10:12", "Biasi (UK)", "Biasi", "24SR", "", "41-970-03", "1998", "2002", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "24", "24", "", "", "79.4", "68.7", "", "50.2", "", "2", "", "", "102", "1", "2", "170", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.7", "79.0", "", "", "", "", "79.5"]} -{"pcdb_id": 8241, "brand_name": "Biasi", "model_name": "28S", "model_qualifier": "", "winter_efficiency_pct": 79.4, "summer_efficiency_pct": 69.3, "comparative_hot_water_efficiency_pct": 48.8, "output_kw_max": 28.0, "final_year_of_manufacture": 2002, "raw": ["008241", "000208", "0", "2006/Jan/17 12:55", "Biasi (UK)", "Biasi", "28S", "", "47-970-07", "1998", "2002", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "28", "28", "", "", "79.4", "69.3", "", "48.8", "", "2", "", "", "104", "1", "2", "170", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.3", "79.0", "", "", "", "", "79.6"]} -{"pcdb_id": 8242, "brand_name": "Biasi", "model_name": "Savio Gaia", "model_qualifier": "424S", "winter_efficiency_pct": 79.2, "summer_efficiency_pct": 69.1, "comparative_hot_water_efficiency_pct": 48.6, "output_kw_max": 24.0, "final_year_of_manufacture": 2002, "raw": ["008242", "000208", "0", "2006/Jan/17 12:55", "Biasi (UK)", "Biasi", "Savio Gaia", "424S", "47-970-08", "1997", "2002", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "24", "24", "", "", "79.2", "69.1", "", "48.6", "", "2", "", "", "104", "1", "2", "150", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.7", "79.0", "", "", "", "", "79.5"]} -{"pcdb_id": 8243, "brand_name": "Biasi", "model_name": "Savio Gaia", "model_qualifier": "428S", "winter_efficiency_pct": 79.4, "summer_efficiency_pct": 69.3, "comparative_hot_water_efficiency_pct": 48.8, "output_kw_max": 28.0, "final_year_of_manufacture": 2002, "raw": ["008243", "000208", "0", "2006/Jan/17 12:55", "Biasi (UK)", "Biasi", "Savio Gaia", "428S", "47-970-09", "1997", "2002", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "28", "28", "", "", "79.4", "69.3", "", "48.8", "", "2", "", "", "104", "1", "2", "170", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.3", "79.0", "", "", "", "", "79.6"]} -{"pcdb_id": 8244, "brand_name": "Biasi", "model_name": "Savio Knightsbridge", "model_qualifier": "424S", "winter_efficiency_pct": 79.2, "summer_efficiency_pct": 69.1, "comparative_hot_water_efficiency_pct": 48.6, "output_kw_max": 24.0, "final_year_of_manufacture": 2002, "raw": ["008244", "000208", "0", "2006/Jan/17 12:55", "Biasi (UK)", "Biasi", "Savio Knightsbridge", "424S", "47-970-08", "1998", "2002", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "24", "24", "", "", "79.2", "69.1", "", "48.6", "", "2", "", "", "104", "1", "2", "150", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.7", "79.0", "", "", "", "", "79.5"]} -{"pcdb_id": 8245, "brand_name": "Biasi", "model_name": "Savio Knightsbridge", "model_qualifier": "428S", "winter_efficiency_pct": 79.4, "summer_efficiency_pct": 69.3, "comparative_hot_water_efficiency_pct": 48.8, "output_kw_max": 28.0, "final_year_of_manufacture": 2002, "raw": ["008245", "000208", "0", "2006/Jan/17 12:55", "Biasi (UK)", "Biasi", "Savio Knightsbridge", "428S", "47-970-09", "1998", "2002", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "28", "28", "", "", "79.4", "69.3", "", "48.8", "", "2", "", "", "104", "1", "2", "170", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.3", "79.0", "", "", "", "", "79.6"]} -{"pcdb_id": 8258, "brand_name": "Biasi", "model_name": "Riva", "model_qualifier": "24S", "winter_efficiency_pct": 79.2, "summer_efficiency_pct": 69.1, "comparative_hot_water_efficiency_pct": 48.6, "output_kw_max": 24.0, "final_year_of_manufacture": 2003, "raw": ["008258", "000208", "0", "2006/Jan/17 12:55", "Biasi (UK)", "Biasi", "Riva", "24S", "47-970-10", "1999", "2003", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "24", "24", "", "", "79.2", "69.1", "", "48.6", "", "2", "", "", "104", "1", "2", "150", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.7", "79.0", "", "", "", "", "79.5"]} -{"pcdb_id": 8259, "brand_name": "Biasi", "model_name": "Riva", "model_qualifier": "24SR", "winter_efficiency_pct": 79.4, "summer_efficiency_pct": 68.7, "comparative_hot_water_efficiency_pct": 50.2, "output_kw_max": 24.0, "final_year_of_manufacture": 2003, "raw": ["008259", "000208", "0", "2012/Mar/27 10:12", "Biasi (UK)", "Biasi", "Riva", "24SR", "41-970-05", "1999", "2003", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "24", "24", "", "", "79.4", "68.7", "", "50.2", "", "2", "", "", "102", "1", "2", "150", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.7", "79.0", "", "", "", "", "79.5"]} -{"pcdb_id": 8260, "brand_name": "Biasi", "model_name": "Riva", "model_qualifier": "28S", "winter_efficiency_pct": 79.4, "summer_efficiency_pct": 69.3, "comparative_hot_water_efficiency_pct": 48.8, "output_kw_max": 28.0, "final_year_of_manufacture": 2003, "raw": ["008260", "000208", "0", "2006/Jan/17 12:55", "Biasi (UK)", "Biasi", "Riva", "28S", "47-970-11", "1999", "2003", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "28", "28", "", "", "79.4", "69.3", "", "48.8", "", "2", "", "", "104", "1", "2", "170", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.3", "79.0", "", "", "", "", "79.6"]} -{"pcdb_id": 8261, "brand_name": "Vokera", "model_name": "Linea Plus AG", "model_qualifier": "", "winter_efficiency_pct": 82.1, "summer_efficiency_pct": 72.0, "comparative_hot_water_efficiency_pct": 50.6, "output_kw_max": 32.0, "final_year_of_manufacture": 2010, "raw": ["008261", "000011", "0", "2010/Oct/21 11:10", "Vokera", "Vokera", "Linea Plus AG", "", "47-094-31", "2000", "2010", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "32", "32", "", "", "82.1", "72.0", "", "50.6", "", "2", "", "", "104", "1", "2", "160", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.4", "84.1", "", "", "", "", "83.8"]} -{"pcdb_id": 8262, "brand_name": "Vokera", "model_name": "Linea", "model_qualifier": "Plus AG", "winter_efficiency_pct": 83.1, "summer_efficiency_pct": 73.0, "comparative_hot_water_efficiency_pct": 51.3, "output_kw_max": 32.0, "final_year_of_manufacture": null, "raw": ["008262", "000011", "0", "2006/Jan/17 12:31", "Vokera", "Vokera", "Linea", "Plus AG", "49BL3161", "1999", "current", "2", "2", "1", "2", "0", "", "", "1", "2", "2", "32", "32", "", "", "83.1", "73.0", "", "51.3", "", "2", "0", "", "104", "1", "2", "0", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "84.9", "86.2", "", "", "", "", "86.0"]} -{"pcdb_id": 8263, "brand_name": "Vokera", "model_name": "Option 24", "model_qualifier": "", "winter_efficiency_pct": 79.3, "summer_efficiency_pct": 69.2, "comparative_hot_water_efficiency_pct": 48.6, "output_kw_max": 23.7, "final_year_of_manufacture": 2010, "raw": ["008263", "000011", "0", "2010/Oct/21 11:23", "Vokera", "Vokera", "Option 24", "", "47-094-32", "2000", "2010", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "23.7", "23.7", "", "", "79.3", "69.2", "", "48.6", "", "2", "", "", "104", "1", "2", "125", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.0", "78.9", "", "", "", "", "79.5"]} -{"pcdb_id": 8265, "brand_name": "Vokera", "model_name": "Mynute 10e", "model_qualifier": "", "winter_efficiency_pct": 77.9, "summer_efficiency_pct": 67.8, "comparative_hot_water_efficiency_pct": 49.5, "output_kw_max": 11.5, "final_year_of_manufacture": 2002, "raw": ["008265", "000011", "0", "2012/Mar/27 10:12", "Vokera", "Vokera", "Mynute 10e", "", "41-094-15", "2000", "2002", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "6", "11.5", "", "", "77.9", "67.8", "", "49.5", "", "2", "", "", "101", "1", "1", "125", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.3", "77.8", "", "", "", "", "78.4"]} -{"pcdb_id": 8267, "brand_name": "Vokera", "model_name": "Mynute 14e", "model_qualifier": "", "winter_efficiency_pct": 80.0, "summer_efficiency_pct": 69.9, "comparative_hot_water_efficiency_pct": 51.0, "output_kw_max": 15.4, "final_year_of_manufacture": 2010, "raw": ["008267", "000011", "0", "2012/Mar/27 10:12", "Vokera", "Vokera", "Mynute 14e", "", "41-094-16", "2000", "2010", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "8.4", "15.40", "", "", "80.0", "69.9", "", "51.0", "", "2", "", "", "101", "1", "1", "125", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "83.2", "80.3", "", "", "", "", "80.8"]} -{"pcdb_id": 8269, "brand_name": "Vokera", "model_name": "Mynute 20e", "model_qualifier": "", "winter_efficiency_pct": 78.9, "summer_efficiency_pct": 68.8, "comparative_hot_water_efficiency_pct": 50.3, "output_kw_max": 19.8, "final_year_of_manufacture": 2010, "raw": ["008269", "000011", "0", "2012/Mar/27 10:12", "Vokera", "Vokera", "Mynute 20e", "", "41-094-17", "2000", "2010", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "14", "19.8", "", "", "78.9", "68.8", "", "50.3", "", "2", "", "", "101", "1", "1", "125", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.7", "79.4", "", "", "", "", "79.8"]} -{"pcdb_id": 8270, "brand_name": "Vokera", "model_name": "Mynute", "model_qualifier": "Mynute 20e LPG", "winter_efficiency_pct": 82.2, "summer_efficiency_pct": 72.1, "comparative_hot_water_efficiency_pct": 52.7, "output_kw_max": 19.8, "final_year_of_manufacture": 2010, "raw": ["008270", "000011", "0", "2012/Mar/27 10:12", "Vokera", "Vokera", "Mynute", "Mynute 20e LPG", "4109417", "2000", "2010", "2", "2", "1", "1", "0", "", "", "1", "2", "2", "14", "19.8", "", "", "82.2", "72.1", "", "52.7", "", "2", "0", "", "101", "1", "1", "125", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "84.8", "82.9", "", "", "", "", "83.3"]} -{"pcdb_id": 8271, "brand_name": "Broag Remeha", "model_name": "Quinta", "model_qualifier": "45", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 40.0, "final_year_of_manufacture": null, "raw": ["008271", "000006", "0", "2012/Mar/27 10:12", "Remeha", "Broag Remeha", "Quinta", "45", "0063BL3253", "2000", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "40", "40", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "85", "10", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.6", "97.0", "", "", "", "", "95.2"]} -{"pcdb_id": 8272, "brand_name": "Broag Remeha", "model_name": "Quinta", "model_qualifier": "65", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 61.0, "final_year_of_manufacture": null, "raw": ["008272", "000006", "0", "2012/Mar/27 10:12", "Remeha", "Broag Remeha", "Quinta", "65", "0063BL3253", "2000", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "61", "61", "", "", "88.6", "79.6", "", "58.2", "", "2", "", "", "102", "1", "2", "90", "10", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.6", "98.1", "", "", "", "", "96.3"]} -{"pcdb_id": 8276, "brand_name": "Vaillant", "model_name": "Turbomax Pro", "model_qualifier": "28E", "winter_efficiency_pct": 80.6, "summer_efficiency_pct": 70.5, "comparative_hot_water_efficiency_pct": 49.6, "output_kw_max": 28.0, "final_year_of_manufacture": 2010, "raw": ["008276", "000031", "0", "2010/Jan/28 08:46", "Vaillant", "Vaillant", "Turbomax Pro", "28E", "VUW GB 282-3", "2000", "2010", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "28.0", "28.0", "", "", "80.6", "70.5", "", "49.6", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.5", "82.0", "", "", "", "", "81.9"]} -{"pcdb_id": 8277, "brand_name": "Vaillant", "model_name": "Thermocompact", "model_qualifier": "628E", "winter_efficiency_pct": 80.8, "summer_efficiency_pct": 70.1, "comparative_hot_water_efficiency_pct": 51.2, "output_kw_max": 28.0, "final_year_of_manufacture": 2010, "raw": ["008277", "000031", "0", "2012/Mar/27 10:12", "Vaillant", "Vaillant", "Thermocompact", "628E", "VU GB 282-5", "2000", "2010", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "28.0", "28.0", "", "", "80.8", "70.1", "", "51.2", "", "2", "", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.5", "82.0", "", "", "", "", "81.9"]} -{"pcdb_id": 8278, "brand_name": "Vaillant", "model_name": "Thermocompact", "model_qualifier": "624E", "winter_efficiency_pct": 80.8, "summer_efficiency_pct": 70.1, "comparative_hot_water_efficiency_pct": 51.2, "output_kw_max": 24.0, "final_year_of_manufacture": 2010, "raw": ["008278", "000031", "0", "2012/Mar/27 10:12", "Vaillant", "Vaillant", "Thermocompact", "624E", "VU GB 424-5", "2000", "2010", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "24.0", "24.0", "", "", "80.8", "70.1", "", "51.2", "", "2", "", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.4", "82.2", "", "", "", "", "82.0"]} -{"pcdb_id": 8279, "brand_name": "Vaillant", "model_name": "Thermocompact", "model_qualifier": "620E", "winter_efficiency_pct": 80.7, "summer_efficiency_pct": 70.0, "comparative_hot_water_efficiency_pct": 51.1, "output_kw_max": 20.0, "final_year_of_manufacture": 2010, "raw": ["008279", "000031", "0", "2012/Mar/27 10:12", "Vaillant", "Vaillant", "Thermocompact", "620E", "VU GB 202-5", "2000", "2010", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "20.0", "20.0", "", "", "80.7", "70.0", "", "51.1", "", "2", "", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.6", "81.8", "", "", "", "", "81.8"]} -{"pcdb_id": 8280, "brand_name": "Vaillant", "model_name": "Thermocompact", "model_qualifier": "615E", "winter_efficiency_pct": 80.0, "summer_efficiency_pct": 69.3, "comparative_hot_water_efficiency_pct": 50.6, "output_kw_max": 15.0, "final_year_of_manufacture": 2010, "raw": ["008280", "000031", "0", "2012/Mar/27 10:12", "Vaillant", "Vaillant", "Thermocompact", "615E", "VU GB 152-5", "2000", "2010", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "15.0", "15.0", "", "", "80.0", "69.3", "", "50.6", "", "2", "", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.7", "80.3", "", "", "", "", "80.6"]} -{"pcdb_id": 8281, "brand_name": "Heating World Group", "model_name": "Grandee", "model_qualifier": "1.40", "winter_efficiency_pct": 85.3, "summer_efficiency_pct": 73.6, "comparative_hot_water_efficiency_pct": 53.7, "output_kw_max": 12.0, "final_year_of_manufacture": null, "raw": ["008281", "000050", "0", "2012/Mar/27 10:12", "Heating World Group", "Heating World Group", "Grandee", "1.40", "", "1997", "current", "4", "2", "1", "1", "0", "", "", "1", "2", "1", "12", "12", "", "", "85.3", "73.6", "", "53.7", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "84.1", "86.4", "", "", "", "", "86.0"]} -{"pcdb_id": 8282, "brand_name": "Heating World Group", "model_name": "Grandee", "model_qualifier": "1.50", "winter_efficiency_pct": 83.6, "summer_efficiency_pct": 71.9, "comparative_hot_water_efficiency_pct": 52.5, "output_kw_max": 15.0, "final_year_of_manufacture": null, "raw": ["008282", "000050", "0", "2012/Mar/27 10:12", "Heating World Group", "Heating World Group", "Grandee", "1.50", "", "1997", "current", "4", "2", "1", "1", "0", "", "", "1", "1", "1", "15", "15", "", "", "83.6", "71.9", "", "52.5", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.3", "84.9", "", "", "", "", "84.4"]} -{"pcdb_id": 8283, "brand_name": "Heating World Group", "model_name": "Grandee", "model_qualifier": "1.60", "winter_efficiency_pct": 83.6, "summer_efficiency_pct": 71.9, "comparative_hot_water_efficiency_pct": 52.5, "output_kw_max": 18.0, "final_year_of_manufacture": null, "raw": ["008283", "000050", "0", "2012/Mar/27 10:12", "Heating World Group", "Heating World Group", "Grandee", "1.60", "", "1997", "current", "4", "2", "1", "1", "0", "", "", "1", "1", "1", "18", "18", "", "", "83.6", "71.9", "", "52.5", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.3", "84.9", "", "", "", "", "84.4"]} -{"pcdb_id": 8284, "brand_name": "Heating World Group", "model_name": "Grandee", "model_qualifier": "2.70", "winter_efficiency_pct": 84.4, "summer_efficiency_pct": 72.7, "comparative_hot_water_efficiency_pct": 53.1, "output_kw_max": 20.0, "final_year_of_manufacture": null, "raw": ["008284", "000050", "0", "2012/Mar/27 10:12", "Heating World Group", "Heating World Group", "Grandee", "2.70", "", "1997", "current", "4", "2", "1", "1", "0", "", "", "1", "2", "1", "20", "20", "", "", "84.4", "72.7", "", "53.1", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.6", "86.1", "", "", "", "", "85.5"]} -{"pcdb_id": 8285, "brand_name": "Heating World Group", "model_name": "Grandee", "model_qualifier": "2.80", "winter_efficiency_pct": 84.4, "summer_efficiency_pct": 72.7, "comparative_hot_water_efficiency_pct": 53.1, "output_kw_max": 24.0, "final_year_of_manufacture": null, "raw": ["008285", "000050", "0", "2012/Mar/27 10:12", "Heating World Group", "Heating World Group", "Grandee", "2.80", "", "1997", "current", "4", "2", "1", "1", "0", "", "", "1", "2", "1", "24", "24", "", "", "84.4", "72.7", "", "53.1", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.6", "86.1", "", "", "", "", "85.5"]} -{"pcdb_id": 8286, "brand_name": "Heating World Group", "model_name": "Grandee", "model_qualifier": "3.100", "winter_efficiency_pct": 84.4, "summer_efficiency_pct": 72.7, "comparative_hot_water_efficiency_pct": 53.1, "output_kw_max": 29.0, "final_year_of_manufacture": null, "raw": ["008286", "000050", "0", "2012/Mar/27 10:12", "Heating World Group", "Heating World Group", "Grandee", "3.100", "", "1997", "current", "4", "2", "1", "1", "0", "", "", "1", "2", "1", "29", "29", "", "", "84.4", "72.7", "", "53.1", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.6", "86.1", "", "", "", "", "85.5"]} -{"pcdb_id": 8287, "brand_name": "Heating World Group", "model_name": "Grandee", "model_qualifier": "3.90", "winter_efficiency_pct": 84.4, "summer_efficiency_pct": 72.7, "comparative_hot_water_efficiency_pct": 53.1, "output_kw_max": 26.0, "final_year_of_manufacture": null, "raw": ["008287", "000050", "0", "2012/Mar/27 10:12", "Heating World Group", "Heating World Group", "Grandee", "3.90", "", "1997", "current", "4", "2", "1", "1", "0", "", "", "1", "2", "1", "26", "26", "", "", "84.4", "72.7", "", "53.1", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.6", "86.1", "", "", "", "", "85.5"]} -{"pcdb_id": 8288, "brand_name": "Heating World Group", "model_name": "Grandee", "model_qualifier": "4.40", "winter_efficiency_pct": 85.3, "summer_efficiency_pct": 73.6, "comparative_hot_water_efficiency_pct": 53.7, "output_kw_max": 12.0, "final_year_of_manufacture": null, "raw": ["008288", "000050", "0", "2012/Mar/27 10:12", "Heating World Group", "Heating World Group", "Grandee", "4.40", "", "1997", "current", "4", "1", "1", "1", "0", "", "", "1", "1", "1", "12", "12", "", "", "85.3", "73.6", "", "53.7", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "84.1", "86.4", "", "", "", "", "86.0"]} -{"pcdb_id": 8289, "brand_name": "Heating World Group", "model_name": "Grandee", "model_qualifier": "4.40 BF", "winter_efficiency_pct": 85.3, "summer_efficiency_pct": 73.6, "comparative_hot_water_efficiency_pct": 53.7, "output_kw_max": 12.0, "final_year_of_manufacture": null, "raw": ["008289", "000050", "0", "2012/Mar/27 10:12", "Heating World Group", "Heating World Group", "Grandee", "4.40 BF", "", "1997", "current", "4", "1", "1", "1", "0", "", "", "1", "2", "1", "12", "12", "", "", "85.3", "73.6", "", "53.7", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "84.1", "86.4", "", "", "", "", "86.0"]} -{"pcdb_id": 8290, "brand_name": "Heating World Group", "model_name": "Grandee", "model_qualifier": "4.50", "winter_efficiency_pct": 83.6, "summer_efficiency_pct": 71.9, "comparative_hot_water_efficiency_pct": 52.5, "output_kw_max": 15.0, "final_year_of_manufacture": null, "raw": ["008290", "000050", "0", "2012/Mar/27 10:12", "Heating World Group", "Heating World Group", "Grandee", "4.50", "", "1997", "current", "4", "1", "1", "1", "0", "", "", "1", "1", "1", "15", "15", "", "", "83.6", "71.9", "", "52.5", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.3", "84.9", "", "", "", "", "84.4"]} -{"pcdb_id": 8291, "brand_name": "Heating World Group", "model_name": "Grandee", "model_qualifier": "4.50 BF", "winter_efficiency_pct": 83.6, "summer_efficiency_pct": 71.9, "comparative_hot_water_efficiency_pct": 52.5, "output_kw_max": 15.0, "final_year_of_manufacture": null, "raw": ["008291", "000050", "0", "2012/Mar/27 10:12", "Heating World Group", "Heating World Group", "Grandee", "4.50 BF", "", "1997", "current", "4", "1", "1", "1", "0", "", "", "1", "2", "1", "15", "15", "", "", "83.6", "71.9", "", "52.5", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.3", "84.9", "", "", "", "", "84.4"]} -{"pcdb_id": 8292, "brand_name": "Heating World Group", "model_name": "Grandee", "model_qualifier": "4.60", "winter_efficiency_pct": 83.6, "summer_efficiency_pct": 71.9, "comparative_hot_water_efficiency_pct": 52.5, "output_kw_max": 18.0, "final_year_of_manufacture": null, "raw": ["008292", "000050", "0", "2012/Mar/27 10:12", "Heating World Group", "Heating World Group", "Grandee", "4.60", "", "1997", "current", "4", "1", "1", "1", "0", "", "", "1", "1", "1", "18", "18", "", "", "83.6", "71.9", "", "52.5", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.3", "84.9", "", "", "", "", "84.4"]} -{"pcdb_id": 8293, "brand_name": "Heating World Group", "model_name": "Grandee", "model_qualifier": "4.60 BF", "winter_efficiency_pct": 83.6, "summer_efficiency_pct": 71.9, "comparative_hot_water_efficiency_pct": 52.5, "output_kw_max": 18.0, "final_year_of_manufacture": null, "raw": ["008293", "000050", "0", "2012/Mar/27 10:12", "Heating World Group", "Heating World Group", "Grandee", "4.60 BF", "", "1997", "current", "4", "1", "1", "1", "0", "", "", "1", "2", "1", "18", "18", "", "", "83.6", "71.9", "", "52.5", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.3", "84.9", "", "", "", "", "84.4"]} -{"pcdb_id": 8294, "brand_name": "Heating World Group", "model_name": "Grandee", "model_qualifier": "5.40", "winter_efficiency_pct": 85.3, "summer_efficiency_pct": 73.6, "comparative_hot_water_efficiency_pct": 53.7, "output_kw_max": 12.0, "final_year_of_manufacture": null, "raw": ["008294", "000050", "0", "2012/Mar/27 10:12", "Heating World Group", "Heating World Group", "Grandee", "5.40", "", "1997", "current", "4", "1", "1", "1", "0", "", "", "1", "1", "1", "12", "12", "", "", "85.3", "73.6", "", "53.7", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "84.1", "86.4", "", "", "", "", "86.0"]} -{"pcdb_id": 8295, "brand_name": "Heating World Group", "model_name": "Grandee", "model_qualifier": "5.40 BF", "winter_efficiency_pct": 85.3, "summer_efficiency_pct": 73.6, "comparative_hot_water_efficiency_pct": 53.7, "output_kw_max": 12.0, "final_year_of_manufacture": null, "raw": ["008295", "000050", "0", "2012/Mar/27 10:12", "Heating World Group", "Heating World Group", "Grandee", "5.40 BF", "", "1997", "current", "4", "1", "1", "1", "0", "", "", "1", "2", "1", "12", "12", "", "", "85.3", "73.6", "", "53.7", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "84.1", "86.4", "", "", "", "", "86.0"]} -{"pcdb_id": 8296, "brand_name": "Heating World Group", "model_name": "Grandee", "model_qualifier": "5.50", "winter_efficiency_pct": 83.6, "summer_efficiency_pct": 71.9, "comparative_hot_water_efficiency_pct": 52.5, "output_kw_max": 15.0, "final_year_of_manufacture": null, "raw": ["008296", "000050", "0", "2012/Mar/27 10:12", "Heating World Group", "Heating World Group", "Grandee", "5.50", "", "1997", "current", "4", "1", "1", "1", "0", "", "", "1", "1", "1", "15", "15", "", "", "83.6", "71.9", "", "52.5", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.3", "84.9", "", "", "", "", "84.4"]} -{"pcdb_id": 8297, "brand_name": "Heating World Group", "model_name": "Grandee", "model_qualifier": "5.50 BF", "winter_efficiency_pct": 83.6, "summer_efficiency_pct": 71.9, "comparative_hot_water_efficiency_pct": 52.5, "output_kw_max": 15.0, "final_year_of_manufacture": null, "raw": ["008297", "000050", "0", "2012/Mar/27 10:12", "Heating World Group", "Heating World Group", "Grandee", "5.50 BF", "", "1997", "current", "4", "1", "1", "1", "0", "", "", "1", "2", "1", "15", "15", "", "", "83.6", "71.9", "", "52.5", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.3", "84.9", "", "", "", "", "84.4"]} -{"pcdb_id": 8298, "brand_name": "Heating World Group", "model_name": "Grandee", "model_qualifier": "5.60", "winter_efficiency_pct": 83.6, "summer_efficiency_pct": 71.9, "comparative_hot_water_efficiency_pct": 52.5, "output_kw_max": 18.0, "final_year_of_manufacture": null, "raw": ["008298", "000050", "0", "2012/Mar/27 10:12", "Heating World Group", "Heating World Group", "Grandee", "5.60", "", "1997", "current", "4", "1", "1", "1", "0", "", "", "1", "1", "1", "18", "18", "", "", "83.6", "71.9", "", "52.5", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.3", "84.9", "", "", "", "", "84.4"]} -{"pcdb_id": 8299, "brand_name": "Heating World Group", "model_name": "Grandee", "model_qualifier": "5.60 BF", "winter_efficiency_pct": 83.6, "summer_efficiency_pct": 71.9, "comparative_hot_water_efficiency_pct": 52.5, "output_kw_max": 18.0, "final_year_of_manufacture": null, "raw": ["008299", "000050", "0", "2012/Mar/27 10:12", "Heating World Group", "Heating World Group", "Grandee", "5.60 BF", "", "1997", "current", "4", "1", "1", "1", "0", "", "", "1", "2", "1", "18", "18", "", "", "83.6", "71.9", "", "52.5", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.3", "84.9", "", "", "", "", "84.4"]} -{"pcdb_id": 8300, "brand_name": "Heating World Group", "model_name": "Grandee", "model_qualifier": "6.60", "winter_efficiency_pct": 85.6, "summer_efficiency_pct": 73.9, "comparative_hot_water_efficiency_pct": 54.0, "output_kw_max": 18.0, "final_year_of_manufacture": null, "raw": ["008300", "000050", "0", "2012/Mar/27 10:12", "Heating World Group", "Heating World Group", "Grandee", "6.60", "", "1997", "current", "4", "1", "1", "1", "0", "", "", "1", "1", "1", "18", "18", "", "", "85.6", "73.9", "", "54.0", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.7", "85.0", "", "", "", "", "85.3"]} -{"pcdb_id": 8301, "brand_name": "Heating World Group", "model_name": "Grandee", "model_qualifier": "6.60 BF", "winter_efficiency_pct": 85.6, "summer_efficiency_pct": 73.9, "comparative_hot_water_efficiency_pct": 54.0, "output_kw_max": 18.0, "final_year_of_manufacture": null, "raw": ["008301", "000050", "0", "2012/Mar/27 10:12", "Heating World Group", "Heating World Group", "Grandee", "6.60 BF", "", "1997", "current", "4", "1", "1", "1", "0", "", "", "1", "2", "1", "18", "18", "", "", "85.6", "73.9", "", "54.0", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.7", "85.0", "", "", "", "", "85.3"]} -{"pcdb_id": 8302, "brand_name": "Heating World Group", "model_name": "Grandee", "model_qualifier": "6.70", "winter_efficiency_pct": 85.6, "summer_efficiency_pct": 73.9, "comparative_hot_water_efficiency_pct": 54.0, "output_kw_max": 20.0, "final_year_of_manufacture": null, "raw": ["008302", "000050", "0", "2012/Mar/27 10:12", "Heating World Group", "Heating World Group", "Grandee", "6.70", "", "1997", "current", "4", "1", "1", "1", "0", "", "", "1", "1", "1", "20", "20", "", "", "85.6", "73.9", "", "54.0", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.7", "85.0", "", "", "", "", "85.3"]} -{"pcdb_id": 8303, "brand_name": "Heating World Group", "model_name": "Grandee", "model_qualifier": "6.70 BF", "winter_efficiency_pct": 85.6, "summer_efficiency_pct": 73.9, "comparative_hot_water_efficiency_pct": 54.0, "output_kw_max": 20.0, "final_year_of_manufacture": null, "raw": ["008303", "000050", "0", "2012/Mar/27 10:12", "Heating World Group", "Heating World Group", "Grandee", "6.70 BF", "", "1997", "current", "4", "1", "1", "1", "0", "", "", "1", "2", "1", "20", "20", "", "", "85.6", "73.9", "", "54.0", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.7", "85.0", "", "", "", "", "85.3"]} -{"pcdb_id": 8304, "brand_name": "Heating World Group", "model_name": "Grandee", "model_qualifier": "6.80", "winter_efficiency_pct": 85.6, "summer_efficiency_pct": 73.9, "comparative_hot_water_efficiency_pct": 54.0, "output_kw_max": 23.0, "final_year_of_manufacture": null, "raw": ["008304", "000050", "0", "2012/Mar/27 10:12", "Heating World Group", "Heating World Group", "Grandee", "6.80", "", "1997", "current", "4", "1", "1", "1", "0", "", "", "1", "1", "1", "23", "23", "", "", "85.6", "73.9", "", "54.0", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.7", "85.0", "", "", "", "", "85.3"]} -{"pcdb_id": 8305, "brand_name": "Heating World Group", "model_name": "Grandee", "model_qualifier": "6.80 BF", "winter_efficiency_pct": 85.6, "summer_efficiency_pct": 73.9, "comparative_hot_water_efficiency_pct": 54.0, "output_kw_max": 23.0, "final_year_of_manufacture": null, "raw": ["008305", "000050", "0", "2012/Mar/27 10:12", "Heating World Group", "Heating World Group", "Grandee", "6.80 BF", "", "1997", "current", "4", "1", "1", "1", "0", "", "", "1", "2", "1", "23", "23", "", "", "85.6", "73.9", "", "54.0", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.7", "85.0", "", "", "", "", "85.3"]} -{"pcdb_id": 8306, "brand_name": "Heating World Group", "model_name": "Grandee", "model_qualifier": "7.90", "winter_efficiency_pct": 85.6, "summer_efficiency_pct": 73.9, "comparative_hot_water_efficiency_pct": 54.0, "output_kw_max": 26.0, "final_year_of_manufacture": null, "raw": ["008306", "000050", "0", "2012/Mar/27 10:12", "Heating World Group", "Heating World Group", "Grandee", "7.90", "", "1997", "current", "4", "1", "1", "1", "0", "", "", "1", "1", "1", "26", "26", "", "", "85.6", "73.9", "", "54.0", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.7", "85.0", "", "", "", "", "85.3"]} -{"pcdb_id": 8307, "brand_name": "Heating World Group", "model_name": "Grandee", "model_qualifier": "7.90 BF", "winter_efficiency_pct": 85.6, "summer_efficiency_pct": 73.9, "comparative_hot_water_efficiency_pct": 54.0, "output_kw_max": 26.0, "final_year_of_manufacture": null, "raw": ["008307", "000050", "0", "2012/Mar/27 10:12", "Heating World Group", "Heating World Group", "Grandee", "7.90 BF", "", "1997", "current", "4", "1", "1", "1", "0", "", "", "1", "2", "1", "26", "26", "", "", "85.6", "73.9", "", "54.0", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.7", "85.0", "", "", "", "", "85.3"]} -{"pcdb_id": 8308, "brand_name": "Heating World Group", "model_name": "Grandee", "model_qualifier": "7.100", "winter_efficiency_pct": 85.6, "summer_efficiency_pct": 73.9, "comparative_hot_water_efficiency_pct": 54.0, "output_kw_max": 29.0, "final_year_of_manufacture": null, "raw": ["008308", "000050", "0", "2012/Mar/27 10:12", "Heating World Group", "Heating World Group", "Grandee", "7.100", "", "1997", "current", "4", "1", "1", "1", "0", "", "", "1", "1", "1", "29", "29", "", "", "85.6", "73.9", "", "54.0", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.7", "85.0", "", "", "", "", "85.3"]} -{"pcdb_id": 8309, "brand_name": "Heating World Group", "model_name": "Grandee", "model_qualifier": "7.100 BF", "winter_efficiency_pct": 85.6, "summer_efficiency_pct": 73.9, "comparative_hot_water_efficiency_pct": 54.0, "output_kw_max": 29.0, "final_year_of_manufacture": null, "raw": ["008309", "000050", "0", "2012/Mar/27 10:12", "Heating World Group", "Heating World Group", "Grandee", "7.100 BF", "", "1997", "current", "4", "1", "1", "1", "0", "", "", "1", "2", "1", "29", "29", "", "", "85.6", "73.9", "", "54.0", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.7", "85.0", "", "", "", "", "85.3"]} -{"pcdb_id": 8310, "brand_name": "Heating World Group", "model_name": "Grandee", "model_qualifier": "7.110", "winter_efficiency_pct": 85.6, "summer_efficiency_pct": 73.9, "comparative_hot_water_efficiency_pct": 54.0, "output_kw_max": 32.0, "final_year_of_manufacture": null, "raw": ["008310", "000050", "0", "2012/Mar/27 10:12", "Heating World Group", "Heating World Group", "Grandee", "7.110", "", "1997", "current", "4", "1", "1", "1", "0", "", "", "1", "1", "1", "32", "32", "", "", "85.6", "73.9", "", "54.0", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.7", "85.0", "", "", "", "", "85.3"]} -{"pcdb_id": 8312, "brand_name": "Heating World Group", "model_name": "Grandee", "model_qualifier": "7.110 BF", "winter_efficiency_pct": 85.6, "summer_efficiency_pct": 73.9, "comparative_hot_water_efficiency_pct": 54.0, "output_kw_max": 32.0, "final_year_of_manufacture": null, "raw": ["008312", "000050", "0", "2012/Mar/27 10:12", "Heating World Group", "Heating World Group", "Grandee", "7.110 BF", "", "1997", "current", "4", "1", "1", "1", "0", "", "", "1", "2", "1", "32", "32", "", "", "85.6", "73.9", "", "54.0", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.7", "85.0", "", "", "", "", "85.3"]} -{"pcdb_id": 8313, "brand_name": "Heating World Group", "model_name": "Grandee", "model_qualifier": "8.120", "winter_efficiency_pct": 85.6, "summer_efficiency_pct": 73.9, "comparative_hot_water_efficiency_pct": 54.0, "output_kw_max": 35.0, "final_year_of_manufacture": null, "raw": ["008313", "000050", "0", "2012/Mar/27 10:12", "Heating World Group", "Heating World Group", "Grandee", "8.120", "", "1997", "current", "4", "1", "1", "1", "0", "", "", "1", "1", "1", "35", "35", "", "", "85.6", "73.9", "", "54.0", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.7", "85.0", "", "", "", "", "85.3"]} -{"pcdb_id": 8314, "brand_name": "Heating World Group", "model_name": "Grandee", "model_qualifier": "8.120 BF", "winter_efficiency_pct": 85.6, "summer_efficiency_pct": 73.9, "comparative_hot_water_efficiency_pct": 54.0, "output_kw_max": 35.0, "final_year_of_manufacture": null, "raw": ["008314", "000050", "0", "2012/Mar/27 10:12", "Heating World Group", "Heating World Group", "Grandee", "8.120 BF", "", "1997", "current", "4", "1", "1", "1", "0", "", "", "1", "2", "1", "35", "35", "", "", "85.6", "73.9", "", "54.0", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.7", "85.0", "", "", "", "", "85.3"]} -{"pcdb_id": 8315, "brand_name": "Heating World Group", "model_name": "Grandee", "model_qualifier": "8.135", "winter_efficiency_pct": 85.6, "summer_efficiency_pct": 73.9, "comparative_hot_water_efficiency_pct": 54.0, "output_kw_max": 40.0, "final_year_of_manufacture": null, "raw": ["008315", "000050", "0", "2012/Mar/27 10:12", "Heating World Group", "Heating World Group", "Grandee", "8.135", "", "1997", "current", "4", "1", "1", "1", "0", "", "", "1", "1", "1", "40", "40", "", "", "85.6", "73.9", "", "54.0", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.7", "85.0", "", "", "", "", "85.3"]} -{"pcdb_id": 8316, "brand_name": "Heating World Group", "model_name": "Grandee", "model_qualifier": "8.135 BF", "winter_efficiency_pct": 85.6, "summer_efficiency_pct": 73.9, "comparative_hot_water_efficiency_pct": 54.0, "output_kw_max": 40.0, "final_year_of_manufacture": null, "raw": ["008316", "000050", "0", "2012/Mar/27 10:12", "Heating World Group", "Heating World Group", "Grandee", "8.135 BF", "", "1997", "current", "4", "1", "1", "1", "0", "", "", "1", "2", "1", "40", "40", "", "", "85.6", "73.9", "", "54.0", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.7", "85.0", "", "", "", "", "85.3"]} -{"pcdb_id": 8317, "brand_name": "Heating World Group", "model_name": "Grandee", "model_qualifier": "8.150", "winter_efficiency_pct": 85.6, "summer_efficiency_pct": 73.9, "comparative_hot_water_efficiency_pct": 54.0, "output_kw_max": 44.0, "final_year_of_manufacture": null, "raw": ["008317", "000050", "0", "2012/Mar/27 10:12", "Heating World Group", "Heating World Group", "Grandee", "8.150", "", "1997", "current", "4", "1", "1", "1", "0", "", "", "1", "1", "1", "44", "44", "", "", "85.6", "73.9", "", "54.0", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.7", "85.0", "", "", "", "", "85.3"]} -{"pcdb_id": 8318, "brand_name": "Heating World Group", "model_name": "Grandee", "model_qualifier": "8.150 BF", "winter_efficiency_pct": 85.6, "summer_efficiency_pct": 73.9, "comparative_hot_water_efficiency_pct": 54.0, "output_kw_max": 44.0, "final_year_of_manufacture": null, "raw": ["008318", "000050", "0", "2012/Mar/27 10:12", "Heating World Group", "Heating World Group", "Grandee", "8.150 BF", "", "1997", "current", "4", "1", "1", "1", "0", "", "", "1", "2", "1", "44", "44", "", "", "85.6", "73.9", "", "54.0", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.7", "85.0", "", "", "", "", "85.3"]} -{"pcdb_id": 8319, "brand_name": "Heating World Group", "model_name": "Sorrento", "model_qualifier": "12/15", "winter_efficiency_pct": 85.3, "summer_efficiency_pct": 73.6, "comparative_hot_water_efficiency_pct": 53.7, "output_kw_max": 12.0, "final_year_of_manufacture": null, "raw": ["008319", "000050", "0", "2012/Mar/27 10:12", "Heating World Group", "Heating World Group", "Sorrento", "12/15", "", "1997", "current", "4", "1", "1", "1", "0", "", "", "1", "1", "1", "12", "12", "", "", "85.3", "73.6", "", "53.7", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "84.1", "86.4", "", "", "", "", "86.0"]} -{"pcdb_id": 8320, "brand_name": "Heating World Group", "model_name": "Sorrento", "model_qualifier": "15/18", "winter_efficiency_pct": 83.6, "summer_efficiency_pct": 71.9, "comparative_hot_water_efficiency_pct": 52.5, "output_kw_max": 15.0, "final_year_of_manufacture": null, "raw": ["008320", "000050", "0", "2012/Mar/27 10:12", "Heating World Group", "Heating World Group", "Sorrento", "15/18", "", "1997", "current", "4", "1", "1", "1", "0", "", "", "1", "1", "1", "15", "15", "", "", "83.6", "71.9", "", "52.5", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.3", "84.9", "", "", "", "", "84.4"]} -{"pcdb_id": 8321, "brand_name": "Heating World Group", "model_name": "Sorrento", "model_qualifier": "18/21", "winter_efficiency_pct": 83.6, "summer_efficiency_pct": 71.9, "comparative_hot_water_efficiency_pct": 52.5, "output_kw_max": 18.0, "final_year_of_manufacture": null, "raw": ["008321", "000050", "0", "2012/Mar/27 10:12", "Heating World Group", "Heating World Group", "Sorrento", "18/21", "", "1997", "current", "4", "1", "1", "1", "0", "", "", "1", "1", "1", "18", "18", "", "", "83.6", "71.9", "", "52.5", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.3", "84.9", "", "", "", "", "84.4"]} -{"pcdb_id": 8322, "brand_name": "Heating World Group", "model_name": "Grandee Combi Floor", "model_qualifier": "15-20", "winter_efficiency_pct": 83.6, "summer_efficiency_pct": 74.1, "comparative_hot_water_efficiency_pct": 52.1, "output_kw_max": 20.0, "final_year_of_manufacture": null, "raw": ["008322", "000050", "0", "2000/Dec/18 13:33", "Heating World Group", "Heating World Group", "Grandee Combi Floor", "15-20", "", "1997", "current", "4", "1", "1", "2", "0", "", "", "1", "1", "1", "15", "20", "", "", "83.6", "74.1", "", "52.1", "", "2", "", "", "202", "1", "1", "", "", "0", "1", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.2", "84.5", "", "", "", "", "85.0"]} -{"pcdb_id": 8323, "brand_name": "Heating World Group", "model_name": "Grandee Combi Floor", "model_qualifier": "15-20 BF", "winter_efficiency_pct": 83.6, "summer_efficiency_pct": 74.1, "comparative_hot_water_efficiency_pct": 52.1, "output_kw_max": 20.0, "final_year_of_manufacture": null, "raw": ["008323", "000050", "0", "2001/Jan/12 10:52", "Heating World Group", "Heating World Group", "Grandee Combi Floor", "15-20 BF", "", "1997", "current", "4", "1", "1", "2", "0", "", "", "1", "2", "1", "15", "20", "", "", "83.6", "74.1", "", "52.1", "", "2", "", "", "202", "1", "1", "", "", "0", "1", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.2", "84.5", "", "", "", "", "85.0"]} -{"pcdb_id": 8324, "brand_name": "Solarcombi", "model_name": "EC-Compact", "model_qualifier": "EC25 H", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 25.0, "final_year_of_manufacture": null, "raw": ["008324", "000209", "0", "2012/Mar/27 10:12", "Coopra BV", "Solarcombi", "EC-Compact", "EC25 H", "", "1998", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "25", "25", "", "", "88.8", "79.8", "", "58.3", "", "2", "", "", "102", "1", "2", "85", "20", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.0", "98.5", "", "", "", "", "96.7"]} -{"pcdb_id": 8326, "brand_name": "Solarcombi", "model_name": "EC-Compact", "model_qualifier": "EC25 HS", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 25.0, "final_year_of_manufacture": null, "raw": ["008326", "000209", "0", "2012/Mar/27 10:12", "Coopra BV", "Solarcombi", "EC-Compact", "EC25 HS", "", "1998", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "25", "25", "", "", "88.8", "79.8", "", "58.3", "", "2", "", "", "102", "1", "2", "85", "20", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.0", "98.5", "", "", "", "", "96.7"]} -{"pcdb_id": 8328, "brand_name": "Solarcombi", "model_name": "EC-Compact", "model_qualifier": "EC25 S", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 56.4, "output_kw_max": 25.0, "final_year_of_manufacture": null, "raw": ["008328", "000209", "0", "2006/Jan/17 12:31", "Coopra BV", "Solarcombi", "EC-Compact", "EC25 S", "", "1998", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "25", "25", "", "", "88.8", "80.2", "", "56.4", "", "2", "", "", "104", "1", "2", "85", "20", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.0", "98.5", "", "", "", "", "96.7"]} -{"pcdb_id": 8331, "brand_name": "Keston", "model_name": "Celsius", "model_qualifier": "25P", "winter_efficiency_pct": 90.0, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 59.2, "output_kw_max": 25.0, "final_year_of_manufacture": null, "raw": ["008331", "000022", "0", "2012/Mar/27 10:12", "Keston Boilers", "Keston", "Celsius", "25P", "Celsius 25P", "2001", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "25", "25", "", "", "90.0", "81.0", "", "59.2", "", "2", "0", "", "102", "1", "2", "160", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "91.0", "98.5", "", "", "", "", "97.1"]} -{"pcdb_id": 8332, "brand_name": "Potterton International Heating", "model_name": "FRS 52", "model_qualifier": "", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": null, "final_year_of_manufacture": 1972, "raw": ["008332", "000005", "0", "2010/Sep/13 17:03", "Potterton International Heating", "Potterton International Heating", "FRS 52", "", "41 595 60", "", "1972", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "", "", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 8336, "brand_name": "MHS Boilers", "model_name": "Strata 1", "model_qualifier": "HE 60", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 60.4, "final_year_of_manufacture": null, "raw": ["008336", "000024", "0", "2012/Mar/27 10:12", "MHS Boilers", "MHS Boilers", "Strata 1", "HE 60", "0063 AT 3341", "1998", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "60.4", "60.4", "", "", "88.8", "79.8", "", "58.3", "", "2", "", "", "102", "1", "2", "115", "20", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "98.7", "", "", "", "", "96.8"]} -{"pcdb_id": 8338, "brand_name": "MHS Boilers", "model_name": "Strata 1", "model_qualifier": "HE-45", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 45.6, "final_year_of_manufacture": null, "raw": ["008338", "000024", "0", "2012/Mar/27 10:12", "MHS Boilers", "MHS Boilers", "Strata 1", "HE-45", "0063 AT 3341", "1998", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "45.6", "45.6", "", "", "88.7", "79.7", "", "58.3", "", "2", "", "", "102", "1", "2", "115", "20", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "98.6", "", "", "", "", "96.6"]} -{"pcdb_id": 8340, "brand_name": "MHS Boilers", "model_name": "Strata 1", "model_qualifier": "HEI-38/45 Combi", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 46.0, "final_year_of_manufacture": null, "raw": ["008340", "000024", "0", "2012/Mar/27 10:12", "MHS Boilers", "MHS Boilers", "Strata 1", "HEI-38/45 Combi", "0063AT3340", "1998", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "46.0", "46.0", "", "", "88.3", "79.3", "", "57.9", "", "2", "", "", "102", "1", "2", "70", "10", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "97.5", "", "", "", "", "95.7"]} -{"pcdb_id": 8342, "brand_name": "MHS Boilers", "model_name": "Strata 1", "model_qualifier": "HE-38", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 38.0, "final_year_of_manufacture": null, "raw": ["008342", "000024", "0", "2012/Mar/27 10:12", "MHS Boilers", "MHS Boilers", "Strata 1", "HE-38", "0063AT3340", "1998", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "38", "38.0", "", "", "88.3", "79.3", "", "57.9", "", "2", "", "", "102", "1", "2", "70", "10", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "97.5", "", "", "", "", "95.7"]} -{"pcdb_id": 8344, "brand_name": "Ariston", "model_name": "Microsystem 28 RFFI", "model_qualifier": "", "winter_efficiency_pct": 81.3, "summer_efficiency_pct": 70.6, "comparative_hot_water_efficiency_pct": 51.6, "output_kw_max": 27.8, "final_year_of_manufacture": 2007, "raw": ["008344", "000080", "0", "2012/Mar/27 10:12", "Merloni TermoSanitari SpA", "Ariston", "Microsystem 28 RFFI", "", "GC No. 41-116-07", "2000", "2007", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "27.8", "27.8", "", "", "81.3", "70.6", "", "51.6", "", "2", "", "", "102", "1", "2", "155", "7", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "84.2", "81.7", "", "", "", "", "82.2"]} -{"pcdb_id": 8346, "brand_name": "Vokera", "model_name": "Linea 24", "model_qualifier": "e", "winter_efficiency_pct": 79.1, "summer_efficiency_pct": 69.0, "comparative_hot_water_efficiency_pct": 48.5, "output_kw_max": 23.7, "final_year_of_manufacture": 2010, "raw": ["008346", "000011", "0", "2010/Oct/21 11:22", "Vokera", "Vokera", "Linea 24", "e", "47-094-27", "2001", "2010", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "23.7", "23.7", "", "", "79.1", "69.0", "", "48.5", "", "2", "", "", "104", "1", "2", "125", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "83.0", "77.7", "", "", "", "", "78.7"]} -{"pcdb_id": 8348, "brand_name": "Vokera", "model_name": "Linea 28", "model_qualifier": "e", "winter_efficiency_pct": 78.9, "summer_efficiency_pct": 68.8, "comparative_hot_water_efficiency_pct": 48.4, "output_kw_max": 28.0, "final_year_of_manufacture": 2010, "raw": ["008348", "000011", "0", "2010/Oct/21 11:22", "Vokera", "Vokera", "Linea 28", "e", "47-094-28", "2001", "2010", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "28", "28", "", "", "78.9", "68.8", "", "48.4", "", "2", "", "", "104", "1", "2", "125", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "83.0", "77.3", "", "", "", "", "78.4"]} -{"pcdb_id": 8349, "brand_name": "Baxi Heating", "model_name": "FF40 from Potterton", "model_qualifier": "", "winter_efficiency_pct": 72.7, "summer_efficiency_pct": 62.6, "comparative_hot_water_efficiency_pct": 45.7, "output_kw_max": 11.72, "final_year_of_manufacture": 2002, "raw": ["008349", "000005", "0", "2012/Mar/27 10:12", "Baxi Heating", "Baxi Heating", "FF40 from Potterton", "", "LTE", "2001", "2002", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "8.79", "11.72", "", "", "72.7", "62.6", "", "45.7", "", "2", "", "", "101", "1", "1", "80", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "74.9", "73.7", "", "", "", "", "73.9"]} -{"pcdb_id": 8350, "brand_name": "Baxi Heating", "model_name": "FF50 from Potterton", "model_qualifier": "", "winter_efficiency_pct": 76.3, "summer_efficiency_pct": 66.2, "comparative_hot_water_efficiency_pct": 48.4, "output_kw_max": 14.65, "final_year_of_manufacture": 2002, "raw": ["008350", "000005", "0", "2012/Mar/27 10:12", "Baxi Heating", "Baxi Heating", "FF50 from Potterton", "", "LTF", "2001", "2002", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "11.72", "14.65", "", "", "76.3", "66.2", "", "48.4", "", "2", "", "", "101", "1", "1", "80", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "78.6", "77.2", "", "", "", "", "77.5"]} -{"pcdb_id": 8351, "brand_name": "Baxi Heating", "model_name": "FF60 from Potterton", "model_qualifier": "", "winter_efficiency_pct": 76.0, "summer_efficiency_pct": 65.9, "comparative_hot_water_efficiency_pct": 48.2, "output_kw_max": 17.58, "final_year_of_manufacture": 2002, "raw": ["008351", "000005", "0", "2012/Mar/27 10:12", "Baxi Heating", "Baxi Heating", "FF60 from Potterton", "", "LTG", "2001", "2002", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "14.65", "17.58", "", "", "76.0", "65.9", "", "48.2", "", "2", "", "", "101", "1", "1", "80", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "78.3", "76.9", "", "", "", "", "77.2"]} -{"pcdb_id": 8352, "brand_name": "Baxi Heating", "model_name": "FF80 from Potterton", "model_qualifier": "", "winter_efficiency_pct": 75.3, "summer_efficiency_pct": 65.2, "comparative_hot_water_efficiency_pct": 47.6, "output_kw_max": 23.45, "final_year_of_manufacture": 2002, "raw": ["008352", "000005", "0", "2012/Mar/27 10:12", "Baxi Heating", "Baxi Heating", "FF80 from Potterton", "", "LTH", "2001", "2002", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "17.58", "23.45", "", "", "75.3", "65.2", "", "47.6", "", "2", "", "", "101", "1", "1", "80", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "77.4", "76.4", "", "", "", "", "76.6"]} -{"pcdb_id": 8353, "brand_name": "Baxi", "model_name": "System", "model_qualifier": "60/100", "winter_efficiency_pct": 79.2, "summer_efficiency_pct": 68.5, "comparative_hot_water_efficiency_pct": 50.1, "output_kw_max": 32.6, "final_year_of_manufacture": 2005, "raw": ["008353", "000005", "0", "2012/Mar/27 10:12", "Baxi SpA", "Baxi", "System", "60/100", "GC no. 47-075-19", "2001", "2005", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "32.6", "32.6", "", "", "79.2", "68.5", "", "50.1", "", "2", "", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.2", "79.3", "", "", "", "", "79.6"]} -{"pcdb_id": 8354, "brand_name": "Baxi", "model_name": "System", "model_qualifier": "35/60", "winter_efficiency_pct": 79.8, "summer_efficiency_pct": 69.1, "comparative_hot_water_efficiency_pct": 50.5, "output_kw_max": 19.4, "final_year_of_manufacture": 2006, "raw": ["008354", "000005", "0", "2012/Mar/27 10:12", "Baxi SpA", "Baxi", "System", "35/60", "GC no. 47-075-18", "2001", "2006", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "19.4", "19.4", "", "", "79.8", "69.1", "", "50.5", "", "2", "", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.1", "79.6", "", "", "", "", "80.0"]} -{"pcdb_id": 8355, "brand_name": "Baxi", "model_name": "Maxflow Combi", "model_qualifier": "FS", "winter_efficiency_pct": 79.7, "summer_efficiency_pct": 70.6, "comparative_hot_water_efficiency_pct": 31.0, "output_kw_max": 31.1, "final_year_of_manufacture": 2003, "raw": ["008355", "000005", "0", "2024/Jan/31 10:17", "Baxi SpA", "Baxi", "Maxflow Combi", "FS", "GC no. 47-075-10", "2001", "2003", "1", "1", "1", "2", "0", "", "", "1", "2", "2", "31.1", "31.1", "", "", "79.7", "70.6", "", "31.0", "", "2", "", "", "106", "1", "2", "", "", "2", "2", "0", "54", "0", "14", "2", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.5", "79.0", "", "", "", "", "79.5"]} -{"pcdb_id": 8356, "brand_name": "Baxi", "model_name": "Maxflow Combi", "model_qualifier": "WM", "winter_efficiency_pct": 79.8, "summer_efficiency_pct": 70.7, "comparative_hot_water_efficiency_pct": 31.1, "output_kw_max": 31.1, "final_year_of_manufacture": 2006, "raw": ["008356", "000005", "0", "2024/Jan/31 10:17", "Baxi SpA", "Baxi", "Maxflow Combi", "WM", "GC no. 47-075-03", "2001", "2006", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "31.1", "31.1", "", "", "79.8", "70.7", "", "31.1", "", "2", "", "", "106", "1", "2", "", "", "2", "2", "0", "54", "0", "14", "2", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.6", "79.2", "", "", "", "", "79.7"]} -{"pcdb_id": 8357, "brand_name": "Baxi", "model_name": "Combi", "model_qualifier": "Instant 105 e", "winter_efficiency_pct": 79.4, "summer_efficiency_pct": 69.3, "comparative_hot_water_efficiency_pct": 48.7, "output_kw_max": 34.3, "final_year_of_manufacture": 2011, "raw": ["008357", "000005", "0", "2013/May/07 10:02", "Baxi SpA", "Baxi", "Combi", "Instant 105 e", "GC no. 47-075-09", "2001", "2011", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "34.3", "34.3", "", "", "79.4", "69.3", "", "48.7", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.6", "79.6", "", "", "", "", "80.0"]} -{"pcdb_id": 8358, "brand_name": "Baxi", "model_name": "Combi", "model_qualifier": "105 e", "winter_efficiency_pct": 79.4, "summer_efficiency_pct": 69.3, "comparative_hot_water_efficiency_pct": 48.7, "output_kw_max": 34.3, "final_year_of_manufacture": 2011, "raw": ["008358", "000005", "0", "2013/May/07 10:03", "Baxi SpA", "Baxi", "Combi", "105 e", "GC no. 47-075-08", "2001", "2011", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "34.3", "34.3", "", "", "79.4", "69.3", "", "48.7", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.6", "79.6", "", "", "", "", "80.0"]} -{"pcdb_id": 8359, "brand_name": "Baxi", "model_name": "Combi", "model_qualifier": "80 Maxflue", "winter_efficiency_pct": 79.4, "summer_efficiency_pct": 69.3, "comparative_hot_water_efficiency_pct": 48.8, "output_kw_max": 26.3, "final_year_of_manufacture": 2003, "raw": ["008359", "000005", "0", "2006/Jan/17 12:55", "Baxi SpA", "Baxi", "Combi", "80 Maxflue", "GC no. 47-075-07", "2001", "2003", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "26.3", "26.3", "", "", "79.4", "69.3", "", "48.8", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.2", "79.1", "", "", "", "", "79.7"]} -{"pcdb_id": 8360, "brand_name": "Baxi", "model_name": "Combi", "model_qualifier": "80 Eco", "winter_efficiency_pct": 79.5, "summer_efficiency_pct": 69.4, "comparative_hot_water_efficiency_pct": 48.8, "output_kw_max": 26.3, "final_year_of_manufacture": 2006, "raw": ["008360", "000005", "0", "2006/Nov/21 10:07", "Baxi SpA", "Baxi", "Combi", "80 Eco", "GC no. 47-075-05", "2001", "2006", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "26.3", "26.3", "", "", "79.5", "69.4", "", "48.8", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.2", "79.2", "", "", "", "", "79.8"]} -{"pcdb_id": 8361, "brand_name": "Baxi", "model_name": "Combi", "model_qualifier": "80 e", "winter_efficiency_pct": 79.5, "summer_efficiency_pct": 69.4, "comparative_hot_water_efficiency_pct": 48.8, "output_kw_max": 26.3, "final_year_of_manufacture": 2011, "raw": ["008361", "000005", "0", "2013/May/07 10:03", "Baxi SpA", "Baxi", "Combi", "80 e", "GC no. 47-075-06", "2001", "2011", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "26.3", "26.3", "", "", "79.5", "69.4", "", "48.8", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.2", "79.2", "", "", "", "", "79.8"]} -{"pcdb_id": 8362, "brand_name": "Worcester", "model_name": "Bosch/British Gas CC1", "model_qualifier": "ZWB 7-29A", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 55.9, "output_kw_max": 29.2, "final_year_of_manufacture": 2002, "raw": ["008362", "000035", "0", "2006/Jan/17 12:55", "Worcester Heat Systems", "Worcester", "Bosch/British Gas CC1", "ZWB 7-29A", "", "2001", "2002", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "29.2", "29.2", "", "", "88.1", "79.5", "", "55.9", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.9", "96.8", "", "", "", "", "95.3"]} -{"pcdb_id": 8363, "brand_name": "Worcester", "model_name": "Bosch/British Gas CS1", "model_qualifier": "ZB 7-28A", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 27.4, "final_year_of_manufacture": 2003, "raw": ["008363", "000035", "0", "2012/Mar/27 10:12", "Worcester Heat Systems", "Worcester", "Bosch/British Gas CS1", "ZB 7-28A", "", "2001", "2003", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "27.4", "27.4", "", "", "88.1", "79.1", "", "57.8", "", "2", "", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.9", "96.8", "", "", "", "", "95.3"]} -{"pcdb_id": 8364, "brand_name": "Worcester", "model_name": "Bosch/British Gas ICC2", "model_qualifier": "ZWBR 8-30A", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 56.5, "output_kw_max": 30.2, "final_year_of_manufacture": 2003, "raw": ["008364", "000035", "0", "2006/Jan/17 12:55", "Worcester Heat Systems", "Worcester", "Bosch/British Gas ICC2", "ZWBR 8-30A", "", "2001", "2003", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "30.2", "30.2", "", "", "88.9", "80.3", "", "56.5", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.5", "98.9", "", "", "", "", "96.9"]} -{"pcdb_id": 8365, "brand_name": "Worcester", "model_name": "Bosch/British Gas ICC2", "model_qualifier": "ZWBR 11-37A", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 56.5, "output_kw_max": 37.1, "final_year_of_manufacture": 2003, "raw": ["008365", "000035", "0", "2006/Jan/17 12:55", "Worcester Heat Systems", "Worcester", "Bosch/British Gas ICC2", "ZWBR 11-37A", "", "2001", "2003", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "37.1", "37.1", "", "", "88.9", "80.3", "", "56.5", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.5", "98.9", "", "", "", "", "96.9"]} -{"pcdb_id": 8366, "brand_name": "Worcester", "model_name": "Bosch/British Gas ICS1", "model_qualifier": "ZSBR 7-28A", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 27.4, "final_year_of_manufacture": 2003, "raw": ["008366", "000035", "0", "2012/Mar/27 10:12", "Worcester Heat Systems", "Worcester", "Bosch/British Gas ICS1", "ZSBR 7-28A", "", "2001", "2003", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "27.4", "27.4", "", "", "88.1", "79.1", "", "57.8", "", "2", "", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.9", "96.8", "", "", "", "", "95.3"]} -{"pcdb_id": 8367, "brand_name": "Worcester", "model_name": "Bosch/British Gas ICS1", "model_qualifier": "ZBR 8-35A", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 34.7, "final_year_of_manufacture": 2003, "raw": ["008367", "000035", "0", "2012/Mar/27 10:12", "Worcester Heat Systems", "Worcester", "Bosch/British Gas ICS1", "ZBR 8-35A", "", "2001", "2003", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "34.7", "34.7", "", "", "88.9", "79.9", "", "58.4", "", "2", "", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.5", "98.9", "", "", "", "", "96.9"]} -{"pcdb_id": 8368, "brand_name": "Worcester", "model_name": "Greenstar HE", "model_qualifier": "ZWB 7-27A", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 55.9, "output_kw_max": 27.2, "final_year_of_manufacture": 2003, "raw": ["008368", "000035", "0", "2006/Jan/17 12:55", "Worcester Heat Systems", "Worcester", "Greenstar HE", "ZWB 7-27A", "", "2001", "2003", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "27.2", "27.2", "", "", "88.1", "79.5", "", "55.9", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.9", "96.8", "", "", "", "", "95.3"]} -{"pcdb_id": 8369, "brand_name": "Worcester", "model_name": "Greenstar HE", "model_qualifier": "ZB 7-27A", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 27.2, "final_year_of_manufacture": 2003, "raw": ["008369", "000035", "0", "2012/Mar/27 10:12", "Worcester Heat Systems", "Worcester", "Greenstar HE", "ZB 7-27A", "", "2001", "2003", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "27.2", "27.2", "", "", "88.1", "79.1", "", "57.8", "", "2", "", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.9", "96.8", "", "", "", "", "95.3"]} -{"pcdb_id": 8370, "brand_name": "Worcester", "model_name": "Greenstar HE Plus", "model_qualifier": "ZWBR 7-28A", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 55.9, "output_kw_max": 28.2, "final_year_of_manufacture": 2003, "raw": ["008370", "000035", "0", "2006/Jan/17 12:55", "Worcester Heat Systems", "Worcester", "Greenstar HE Plus", "ZWBR 7-28A", "", "2001", "2003", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28.2", "28.2", "", "", "88.1", "79.5", "", "55.9", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.9", "96.8", "", "", "", "", "95.3"]} -{"pcdb_id": 8371, "brand_name": "Worcester", "model_name": "Greenstar HE Plus", "model_qualifier": "ZWBR 11-35A", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 56.5, "output_kw_max": 35.1, "final_year_of_manufacture": 2003, "raw": ["008371", "000035", "0", "2006/Jan/17 12:55", "Worcester Heat Systems", "Worcester", "Greenstar HE Plus", "ZWBR 11-35A", "", "2001", "2003", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "35.1", "35.1", "", "", "88.9", "80.3", "", "56.5", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.5", "98.9", "", "", "", "", "96.9"]} -{"pcdb_id": 8372, "brand_name": "Grant", "model_name": "Outdoor", "model_qualifier": "Combi Mk II", "winter_efficiency_pct": 84.9, "summer_efficiency_pct": 75.4, "comparative_hot_water_efficiency_pct": 53.0, "output_kw_max": 26.37, "final_year_of_manufacture": null, "raw": ["008372", "000048", "0", "2001/Jun/19 15:56", "Grant Engineering", "Grant", "Outdoor", "Combi Mk II", "", "1997", "current", "4", "1", "2", "2", "0", "", "", "1", "1", "2", "26.37", "26.37", "", "", "84.9", "75.4", "", "53.0", "", "2", "", "", "202", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.4", "88.0", "", "", "", "", "87.7"]} -{"pcdb_id": 8373, "brand_name": "Alpha", "model_name": "240p", "model_qualifier": "", "winter_efficiency_pct": 71.0, "summer_efficiency_pct": 61.0, "comparative_hot_water_efficiency_pct": 42.8, "output_kw_max": 23.3, "final_year_of_manufacture": 1999, "raw": ["008373", "000001", "0", "2010/Sep/13 17:03", "Alpha Therm", "Alpha", "240p", "", "", "1996", "1999", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "23.3", "23.3", "", "", "71.0", "61.0", "", "42.8", "", "3", "", "", "0", "2", "2", "170", "5", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 8374, "brand_name": "Alpha", "model_name": "240xe", "model_qualifier": "", "winter_efficiency_pct": 71.0, "summer_efficiency_pct": 61.0, "comparative_hot_water_efficiency_pct": 42.8, "output_kw_max": 23.3, "final_year_of_manufacture": 1998, "raw": ["008374", "000001", "0", "2010/Sep/13 17:03", "Alpha Therm", "Alpha", "240xe", "", "", "1996", "1998", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "23.3", "23.3", "", "", "71.0", "61.0", "", "42.8", "", "3", "", "", "0", "1", "2", "170", "5", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 8375, "brand_name": "Alpha", "model_name": "240xp", "model_qualifier": "", "winter_efficiency_pct": 71.0, "summer_efficiency_pct": 61.0, "comparative_hot_water_efficiency_pct": 42.8, "output_kw_max": 23.3, "final_year_of_manufacture": 1998, "raw": ["008375", "000001", "0", "2010/Sep/13 17:03", "Alpha Therm", "Alpha", "240xp", "", "", "1996", "1998", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "23.3", "23.3", "", "", "71.0", "61.0", "", "42.8", "", "3", "", "", "0", "2", "2", "170", "5", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 8378, "brand_name": "Glow-worm", "model_name": "Xtramax", "model_qualifier": "A", "winter_efficiency_pct": 79.7, "summer_efficiency_pct": 70.6, "comparative_hot_water_efficiency_pct": 38.0, "output_kw_max": 27.6, "final_year_of_manufacture": null, "raw": ["008378", "000207", "0", "2024/Jan/31 10:17", "Saunier Duval", "Glow-worm", "Xtramax", "A", "GC 47-047-15", "2001", "current", "1", "3", "1", "2", "0", "", "", "1", "2", "2", "27.6", "27.6", "", "", "79.7", "70.6", "", "38.0", "", "2", "", "", "106", "1", "2", "235", "15", "2", "2", "0", "42", "0", "15", "2", "60", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "83.2", "77.9", "", "", "", "", "78.9"]} -{"pcdb_id": 8379, "brand_name": "Saunier Duval", "model_name": "Isomax F28E", "model_qualifier": "A", "winter_efficiency_pct": 79.7, "summer_efficiency_pct": 70.6, "comparative_hot_water_efficiency_pct": 38.0, "output_kw_max": 27.6, "final_year_of_manufacture": null, "raw": ["008379", "000206", "0", "2024/Jan/31 10:17", "Saunier Duval", "Saunier Duval", "Isomax F28E", "A", "GC 47-920-28", "2001", "current", "1", "3", "1", "2", "0", "", "", "1", "2", "2", "27.6", "27.6", "", "", "79.7", "70.6", "", "38.0", "", "2", "", "", "106", "1", "2", "235", "15", "2", "2", "0", "42", "0", "15", "2", "60", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "83.2", "77.9", "", "", "", "", "78.9"]} -{"pcdb_id": 8380, "brand_name": "Alpha", "model_name": "CB28X", "model_qualifier": "", "winter_efficiency_pct": 81.0, "summer_efficiency_pct": 70.9, "comparative_hot_water_efficiency_pct": 49.8, "output_kw_max": 28.0, "final_year_of_manufacture": 2005, "raw": ["008380", "000001", "0", "2011/Sep/06 13:08", "Alpha Therm", "Alpha", "CB28X", "", "", "2001", "2005", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "28.0", "28.0", "", "", "81.0", "70.9", "", "49.8", "", "2", "", "", "104", "1", "2", "170", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "83.3", "81.5", "", "", "", "", "81.8"]} -{"pcdb_id": 8382, "brand_name": "Aquaflame", "model_name": "HE 15", "model_qualifier": "", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 15.0, "final_year_of_manufacture": null, "raw": ["008382", "000039", "0", "2012/Mar/27 10:12", "Aquaflame", "Aquaflame", "HE 15", "", "", "2001", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "15", "15", "", "", "87.9", "80.1", "", "58.5", "", "2", "", "", "201", "1", "1", "100", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.6", "94.1", "", "", "", "", "93.6"]} -{"pcdb_id": 8383, "brand_name": "Aquaflame", "model_name": "HE 19", "model_qualifier": "", "winter_efficiency_pct": 87.8, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 19.0, "final_year_of_manufacture": null, "raw": ["008383", "000039", "0", "2012/Mar/27 10:12", "Aquaflame", "Aquaflame", "HE 19", "", "", "2001", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "19", "19", "", "", "87.8", "80.0", "", "58.4", "", "2", "", "", "201", "1", "1", "100", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "92.0", "93.7", "", "", "", "", "93.4"]} -{"pcdb_id": 8386, "brand_name": "Aquaflame", "model_name": "HE 22", "model_qualifier": "", "winter_efficiency_pct": 87.2, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 21.3, "final_year_of_manufacture": null, "raw": ["008386", "000039", "0", "2012/Mar/27 10:12", "Aquaflame", "Aquaflame", "HE 22", "", "", "2001", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "21.3", "21.3", "", "", "87.2", "79.4", "", "58.0", "", "2", "", "", "201", "1", "1", "100", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.1", "92.6", "", "", "", "", "92.3"]} -{"pcdb_id": 8387, "brand_name": "Viessmann", "model_name": "Vitodens 200", "model_qualifier": "WB2-44kW", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 44.0, "final_year_of_manufacture": 2005, "raw": ["008387", "000033", "0", "2012/Mar/27 10:12", "Viessmann", "Viessmann", "Vitodens 200", "WB2-44kW", "", "", "2005", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "44.0", "44.0", "", "", "88.5", "79.5", "", "58.1", "", "2", "", "", "102", "1", "2", "72", "11", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "98.0", "", "", "", "", "96.1"]} -{"pcdb_id": 8388, "brand_name": "Viessmann", "model_name": "Vitodens 200", "model_qualifier": "WB2-66kW", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 60.0, "final_year_of_manufacture": 2005, "raw": ["008388", "000033", "0", "2012/Mar/27 10:12", "Viessmann", "Viessmann", "Vitodens 200", "WB2-66kW", "", "", "2005", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "60.0", "60.0", "", "", "88.5", "79.5", "", "58.1", "", "2", "", "", "102", "1", "2", "104", "11", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "98.2", "", "", "", "", "96.2"]} -{"pcdb_id": 8389, "brand_name": "Viessmann", "model_name": "Vitodens 200", "model_qualifier": "WB2-32kW", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 32.0, "final_year_of_manufacture": 2005, "raw": ["008389", "000033", "0", "2012/Mar/27 10:12", "Viessmann", "Viessmann", "Vitodens 200", "WB2-32kW", "", "", "2005", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "32.0", "32.0", "", "", "88.7", "79.7", "", "58.2", "", "2", "", "", "102", "1", "2", "148", "11", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "98.5", "", "", "", "", "96.5"]} -{"pcdb_id": 8390, "brand_name": "Viessmann", "model_name": "Vitodens 200 Combi", "model_qualifier": "WB2-24kW", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 56.4, "output_kw_max": 24.0, "final_year_of_manufacture": 2005, "raw": ["008390", "000033", "0", "2006/Jan/17 12:55", "Viessmann", "Viessmann", "Vitodens 200 Combi", "WB2-24kW", "", "", "2005", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.0", "24.0", "", "", "88.7", "80.1", "", "56.4", "", "2", "", "", "104", "1", "2", "130", "11", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "98.7", "", "", "", "", "96.6"]} -{"pcdb_id": 8391, "brand_name": "Viessmann", "model_name": "Vitodens 200", "model_qualifier": "WB2-24kW", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 24.0, "final_year_of_manufacture": 2005, "raw": ["008391", "000033", "0", "2012/Mar/27 10:12", "Viessmann", "Viessmann", "Vitodens 200", "WB2-24kW", "", "", "2005", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24.0", "24.0", "", "", "88.7", "79.7", "", "58.2", "", "2", "", "", "102", "1", "2", "130", "11", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "98.7", "", "", "", "", "96.6"]} -{"pcdb_id": 8392, "brand_name": "Viessmann", "model_name": "Vitodens 200", "model_qualifier": "WB2-11kW", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 11.0, "final_year_of_manufacture": 2005, "raw": ["008392", "000033", "0", "2012/Mar/27 10:12", "Viessmann", "Viessmann", "Vitodens 200", "WB2-11kW", "", "", "2005", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "11.0", "11.0", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "101", "11", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.7", "97.8", "", "", "", "", "95.9"]} -{"pcdb_id": 8393, "brand_name": "Viessmann", "model_name": "Vitopend 100 Combi", "model_qualifier": "WH1-24kW", "winter_efficiency_pct": 76.2, "summer_efficiency_pct": 66.1, "comparative_hot_water_efficiency_pct": 46.4, "output_kw_max": 24.0, "final_year_of_manufacture": 2005, "raw": ["008393", "000033", "0", "2006/Jan/17 12:55", "Viessmann", "Viessmann", "Vitopend 100 Combi", "WH1-24kW", "", "", "2005", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "24.0", "24.0", "", "", "76.2", "66.1", "", "46.4", "", "2", "", "", "104", "1", "2", "143", "7", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "80.2", "74.5", "", "", "", "", "75.6"]} -{"pcdb_id": 8394, "brand_name": "Ravenheat", "model_name": "RSF 100ET*", "model_qualifier": "", "winter_efficiency_pct": 79.8, "summer_efficiency_pct": 69.7, "comparative_hot_water_efficiency_pct": 49.0, "output_kw_max": 29.66, "final_year_of_manufacture": null, "raw": ["008394", "000026", "0", "2015/Sep/03 13:02", "Ravenheat", "Ravenheat", "RSF 100ET*", "", "G.C No 47 581 26A", "2001", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "29.66", "29.66", "", "", "79.8", "69.7", "", "49.0", "", "2", "", "", "104", "1", "2", "160", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.5", "80.5", "", "", "", "", "80.7"]} -{"pcdb_id": 8395, "brand_name": "Ravenheat", "model_name": "RSF 100E*", "model_qualifier": "", "winter_efficiency_pct": 79.8, "summer_efficiency_pct": 69.7, "comparative_hot_water_efficiency_pct": 49.0, "output_kw_max": 29.7, "final_year_of_manufacture": null, "raw": ["008395", "000026", "0", "2006/Jan/17 12:31", "Ravenheat", "Ravenheat", "RSF 100E*", "", "G.C. No 47 581 25A", "2001", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "29.7", "29.7", "", "", "79.8", "69.7", "", "49.0", "", "2", "", "", "104", "1", "2", "160", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.5", "80.5", "", "", "", "", "80.7"]} -{"pcdb_id": 8396, "brand_name": "Ravenheat", "model_name": "RSF 84E*", "model_qualifier": "", "winter_efficiency_pct": 79.7, "summer_efficiency_pct": 69.6, "comparative_hot_water_efficiency_pct": 48.9, "output_kw_max": 24.6, "final_year_of_manufacture": null, "raw": ["008396", "000026", "0", "2006/Jan/17 12:31", "Ravenheat", "Ravenheat", "RSF 84E*", "", "G.C. No 47 581 27A", "2001", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "24.6", "24.6", "", "", "79.7", "69.6", "", "48.9", "", "2", "", "", "104", "1", "2", "160", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.4", "79.4", "", "", "", "", "79.9"]} -{"pcdb_id": 8397, "brand_name": "Ravenheat", "model_name": "RSF 84ET*", "model_qualifier": "", "winter_efficiency_pct": 79.7, "summer_efficiency_pct": 69.6, "comparative_hot_water_efficiency_pct": 48.9, "output_kw_max": 24.6, "final_year_of_manufacture": null, "raw": ["008397", "000026", "0", "2006/Jan/17 12:31", "Ravenheat", "Ravenheat", "RSF 84ET*", "", "G.C No 47 581 28A", "2001", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "24.6", "24.6", "", "", "79.7", "69.6", "", "48.9", "", "2", "", "", "104", "1", "2", "160", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.4", "79.4", "", "", "", "", "79.9"]} -{"pcdb_id": 8398, "brand_name": "Ravenheat", "model_name": "RSF 84ET*", "model_qualifier": "", "winter_efficiency_pct": 81.5, "summer_efficiency_pct": 71.4, "comparative_hot_water_efficiency_pct": 50.2, "output_kw_max": 24.6, "final_year_of_manufacture": null, "raw": ["008398", "000026", "0", "2006/Jan/17 12:31", "Ravenheat", "Ravenheat", "RSF 84ET*", "", "G.C. No 47 581 28A", "2001", "current", "2", "2", "1", "2", "0", "", "", "1", "2", "2", "24.6", "24.6", "", "", "81.5", "71.4", "", "50.2", "", "2", "0", "", "104", "1", "2", "160", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "84.2", "81.1", "", "", "", "", "81.7"]} -{"pcdb_id": 8399, "brand_name": "Ravenheat", "model_name": "RSF 84E*", "model_qualifier": "", "winter_efficiency_pct": 81.5, "summer_efficiency_pct": 71.4, "comparative_hot_water_efficiency_pct": 50.2, "output_kw_max": 24.6, "final_year_of_manufacture": null, "raw": ["008399", "000026", "0", "2006/Jan/17 12:31", "Ravenheat", "Ravenheat", "RSF 84E*", "", "G.C No 47 581 27A", "2001", "current", "2", "2", "1", "2", "0", "", "", "1", "2", "2", "24.6", "24.6", "", "", "81.5", "71.4", "", "50.2", "", "2", "0", "", "104", "1", "2", "160", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "84.2", "81.1", "", "", "", "", "81.7"]} -{"pcdb_id": 8400, "brand_name": "Ravenheat", "model_name": "RSF 100ET*", "model_qualifier": "", "winter_efficiency_pct": 81.6, "summer_efficiency_pct": 71.5, "comparative_hot_water_efficiency_pct": 50.3, "output_kw_max": 29.7, "final_year_of_manufacture": null, "raw": ["008400", "000026", "0", "2006/Jan/17 12:31", "Ravenheat", "Ravenheat", "RSF 100ET*", "", "G.C No 47 581 26A", "2001", "current", "2", "2", "1", "2", "0", "", "", "1", "2", "2", "29.7", "29.7", "", "", "81.6", "71.5", "", "50.3", "", "2", "0", "", "104", "1", "2", "160", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "83.4", "82.3", "", "", "", "", "82.5"]} -{"pcdb_id": 8401, "brand_name": "Ravenheat", "model_name": "RSF 100E*", "model_qualifier": "", "winter_efficiency_pct": 81.6, "summer_efficiency_pct": 71.5, "comparative_hot_water_efficiency_pct": 50.3, "output_kw_max": 29.7, "final_year_of_manufacture": null, "raw": ["008401", "000026", "0", "2006/Jan/17 12:31", "Ravenheat", "Ravenheat", "RSF 100E*", "", "G.C No 47 581 25A", "2001", "current", "2", "2", "1", "2", "0", "", "", "1", "2", "2", "29.7", "29.7", "", "", "81.6", "71.5", "", "50.3", "", "2", "0", "", "104", "1", "2", "160", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "83.4", "82.3", "", "", "", "", "82.5"]} -{"pcdb_id": 8402, "brand_name": "Grant", "model_name": "Euroflame", "model_qualifier": "Kitchen/Utility 90-120", "winter_efficiency_pct": 85.5, "summer_efficiency_pct": 73.8, "comparative_hot_water_efficiency_pct": 53.9, "output_kw_max": 35.2, "final_year_of_manufacture": null, "raw": ["008402", "000048", "0", "2012/Mar/27 10:12", "Grant Engineering", "Grant", "Euroflame", "Kitchen/Utility 90-120", "", "2001", "current", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "26.4", "35.2", "", "", "85.5", "73.8", "", "53.9", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.2", "85.9", "", "", "", "", "85.8"]} -{"pcdb_id": 8403, "brand_name": "Grant", "model_name": "Euroflame", "model_qualifier": "90-120 System Kitchen Utility", "winter_efficiency_pct": 85.5, "summer_efficiency_pct": 73.8, "comparative_hot_water_efficiency_pct": 53.9, "output_kw_max": 35.2, "final_year_of_manufacture": null, "raw": ["008403", "000048", "0", "2012/Mar/27 10:12", "Grant Engineering", "Grant", "Euroflame", "90-120 System Kitchen Utility", "", "2001", "current", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "26.4", "35.2", "", "", "85.5", "73.8", "", "53.9", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.2", "85.9", "", "", "", "", "85.8"]} -{"pcdb_id": 8404, "brand_name": "Grant", "model_name": "Euroflame", "model_qualifier": "90-120 Boilerhouse", "winter_efficiency_pct": 85.5, "summer_efficiency_pct": 73.8, "comparative_hot_water_efficiency_pct": 53.9, "output_kw_max": 35.2, "final_year_of_manufacture": null, "raw": ["008404", "000048", "0", "2012/Mar/27 10:12", "Grant Engineering", "Grant", "Euroflame", "90-120 Boilerhouse", "", "2001", "current", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "26.4", "35.2", "", "", "85.5", "73.8", "", "53.9", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.2", "85.9", "", "", "", "", "85.8"]} -{"pcdb_id": 8405, "brand_name": "Grant", "model_name": "Euroflame", "model_qualifier": "90-120 Outdoor", "winter_efficiency_pct": 85.5, "summer_efficiency_pct": 73.8, "comparative_hot_water_efficiency_pct": 53.9, "output_kw_max": 35.2, "final_year_of_manufacture": null, "raw": ["008405", "000048", "0", "2012/Mar/27 10:12", "Grant Engineering", "Grant", "Euroflame", "90-120 Outdoor", "", "2001", "current", "4", "1", "2", "1", "0", "", "", "1", "2", "2", "26.4", "35.2", "", "", "85.5", "73.8", "", "53.9", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.2", "85.9", "", "", "", "", "85.8"]} -{"pcdb_id": 8406, "brand_name": "Baxi", "model_name": "Solo 3 PFL", "model_qualifier": "30", "winter_efficiency_pct": 80.3, "summer_efficiency_pct": 70.2, "comparative_hot_water_efficiency_pct": 51.3, "output_kw_max": 10.99, "final_year_of_manufacture": 2008, "raw": ["008406", "000005", "0", "2012/Mar/27 10:12", "Baxi UK", "Baxi", "Solo 3 PFL", "30", "GC No. 41-075-20", "2001", "2008", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "10.99", "10.99", "", "", "80.3", "70.2", "", "51.3", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.7", "81.1", "", "", "", "", "81.4"]} -{"pcdb_id": 8407, "brand_name": "Baxi", "model_name": "Solo 3 PFL", "model_qualifier": "40", "winter_efficiency_pct": 79.3, "summer_efficiency_pct": 69.2, "comparative_hot_water_efficiency_pct": 50.6, "output_kw_max": 14.65, "final_year_of_manufacture": 2008, "raw": ["008407", "000005", "0", "2012/Mar/27 10:12", "Baxi UK", "Baxi", "Solo 3 PFL", "40", "GC No. 41-075-21", "2001", "2008", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "14.65", "14.65", "", "", "79.3", "69.2", "", "50.6", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.5", "80.3", "", "", "", "", "80.5"]} -{"pcdb_id": 8408, "brand_name": "Baxi", "model_name": "Solo 3 PFL", "model_qualifier": "50", "winter_efficiency_pct": 78.9, "summer_efficiency_pct": 68.8, "comparative_hot_water_efficiency_pct": 50.3, "output_kw_max": 18.3, "final_year_of_manufacture": 2010, "raw": ["008408", "000005", "0", "2012/Mar/27 10:12", "Baxi UK", "Baxi", "Solo 3 PFL", "50", "GC No. 41-075-22", "2001", "2010", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "18.3", "18.3", "", "", "78.9", "68.8", "", "50.3", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "80.9", "80.1", "", "", "", "", "80.3"]} -{"pcdb_id": 8409, "brand_name": "Baxi", "model_name": "Solo 3 PFL", "model_qualifier": "60", "winter_efficiency_pct": 79.4, "summer_efficiency_pct": 69.3, "comparative_hot_water_efficiency_pct": 50.7, "output_kw_max": 22.0, "final_year_of_manufacture": 2010, "raw": ["008409", "000005", "0", "2012/Mar/27 10:12", "Baxi UK", "Baxi", "Solo 3 PFL", "60", "GC No. 41-075-23", "2001", "2010", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "22", "22.0", "", "", "79.4", "69.3", "", "50.7", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.5", "80.5", "", "", "", "", "80.7"]} -{"pcdb_id": 8410, "brand_name": "Baxi", "model_name": "Solo 3 PFL", "model_qualifier": "70", "winter_efficiency_pct": 79.1, "summer_efficiency_pct": 69.0, "comparative_hot_water_efficiency_pct": 50.4, "output_kw_max": 25.64, "final_year_of_manufacture": 2008, "raw": ["008410", "000005", "0", "2012/Mar/27 10:12", "Baxi UK", "Baxi", "Solo 3 PFL", "70", "GC No. 41-075-24", "2001", "2008", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "25.64", "25.64", "", "", "79.1", "69.0", "", "50.4", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.1", "80.3", "", "", "", "", "80.4"]} -{"pcdb_id": 8411, "brand_name": "Baxi", "model_name": "Solo 3 PFL System", "model_qualifier": "30", "winter_efficiency_pct": 80.3, "summer_efficiency_pct": 70.2, "comparative_hot_water_efficiency_pct": 51.3, "output_kw_max": 10.99, "final_year_of_manufacture": 2006, "raw": ["008411", "000005", "0", "2012/Mar/27 10:12", "Baxi UK", "Baxi", "Solo 3 PFL System", "30", "GC No. 41-075-25", "2001", "2006", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "10.99", "10.99", "", "", "80.3", "70.2", "", "51.3", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.7", "81.1", "", "", "", "", "81.4"]} -{"pcdb_id": 8412, "brand_name": "Baxi", "model_name": "Solo 3 PFL System", "model_qualifier": "40", "winter_efficiency_pct": 79.3, "summer_efficiency_pct": 69.2, "comparative_hot_water_efficiency_pct": 50.6, "output_kw_max": 14.65, "final_year_of_manufacture": 2006, "raw": ["008412", "000005", "0", "2012/Mar/27 10:12", "Baxi UK", "Baxi", "Solo 3 PFL System", "40", "GC No. 41-075-26", "2001", "2006", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "14.65", "14.65", "", "", "79.3", "69.2", "", "50.6", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.5", "80.3", "", "", "", "", "80.5"]} -{"pcdb_id": 8413, "brand_name": "Baxi", "model_name": "Solo 3 PFL System", "model_qualifier": "50", "winter_efficiency_pct": 78.9, "summer_efficiency_pct": 68.8, "comparative_hot_water_efficiency_pct": 50.3, "output_kw_max": 18.3, "final_year_of_manufacture": 2006, "raw": ["008413", "000005", "0", "2012/Mar/27 10:12", "Baxi UK", "Baxi", "Solo 3 PFL System", "50", "GC No. 41-075-27", "2001", "2006", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "18.3", "18.3", "", "", "78.9", "68.8", "", "50.3", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "80.9", "80.1", "", "", "", "", "80.3"]} -{"pcdb_id": 8414, "brand_name": "Baxi", "model_name": "Solo 3 PFL System", "model_qualifier": "60", "winter_efficiency_pct": 79.4, "summer_efficiency_pct": 69.3, "comparative_hot_water_efficiency_pct": 50.7, "output_kw_max": 22.0, "final_year_of_manufacture": 2006, "raw": ["008414", "000005", "0", "2012/Mar/27 10:12", "Baxi UK", "Baxi", "Solo 3 PFL System", "60", "GC No. 41-075-28", "2001", "2006", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "22", "22.0", "", "", "79.4", "69.3", "", "50.7", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.5", "80.5", "", "", "", "", "80.7"]} -{"pcdb_id": 8415, "brand_name": "Baxi", "model_name": "Solo 3 PFL System", "model_qualifier": "70", "winter_efficiency_pct": 79.1, "summer_efficiency_pct": 69.0, "comparative_hot_water_efficiency_pct": 50.4, "output_kw_max": 25.64, "final_year_of_manufacture": 2006, "raw": ["008415", "000005", "0", "2012/Mar/27 10:12", "Baxi UK", "Baxi", "Solo 3 PFL System", "70", "GC No. 41-075-29", "2001", "2006", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "25.64", "25.64", "", "", "79.1", "69.0", "", "50.4", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.1", "80.3", "", "", "", "", "80.4"]} -{"pcdb_id": 8416, "brand_name": "Grant", "model_name": "Multipass", "model_qualifier": "System 50-70", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 20.5, "final_year_of_manufacture": null, "raw": ["008416", "000048", "0", "2012/Mar/27 10:12", "Grant Engineering", "Grant", "Multipass", "System 50-70", "", "1998", "current", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "14.6", "20.5", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "90.0", "87.6", "", "", "", "", "88.1"]} -{"pcdb_id": 8417, "brand_name": "Grant", "model_name": "Multipass", "model_qualifier": "System 70-90", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 26.37, "final_year_of_manufacture": null, "raw": ["008417", "000048", "0", "2012/Mar/27 10:12", "Grant Engineering", "Grant", "Multipass", "System 70-90", "", "1998", "current", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "20.52", "26.37", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "89.8", "87.3", "", "", "", "", "87.8"]} -{"pcdb_id": 8418, "brand_name": "Grant", "model_name": "Multipass", "model_qualifier": "System 90-110", "winter_efficiency_pct": 86.5, "summer_efficiency_pct": 74.8, "comparative_hot_water_efficiency_pct": 54.7, "output_kw_max": 32.24, "final_year_of_manufacture": null, "raw": ["008418", "000048", "0", "2012/Mar/27 10:12", "Grant Engineering", "Grant", "Multipass", "System 90-110", "", "1998", "current", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "26.37", "32.24", "", "", "86.5", "74.8", "", "54.7", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.9", "86.9", "", "", "", "", "87.1"]} -{"pcdb_id": 8419, "brand_name": "Grant", "model_name": "Multipass", "model_qualifier": "System 110-140", "winter_efficiency_pct": 86.5, "summer_efficiency_pct": 74.8, "comparative_hot_water_efficiency_pct": 54.7, "output_kw_max": 41.0, "final_year_of_manufacture": null, "raw": ["008419", "000048", "0", "2012/Mar/27 10:12", "Grant Engineering", "Grant", "Multipass", "System 110-140", "", "1998", "current", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "32.24", "41.0", "", "", "86.5", "74.8", "", "54.7", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.9", "86.9", "", "", "", "", "87.1"]} -{"pcdb_id": 8420, "brand_name": "Grant", "model_name": "Multipass", "model_qualifier": "Outdoor 110-140", "winter_efficiency_pct": 86.5, "summer_efficiency_pct": 74.8, "comparative_hot_water_efficiency_pct": 54.7, "output_kw_max": 41.03, "final_year_of_manufacture": null, "raw": ["008420", "000048", "0", "2012/Mar/27 10:12", "Grant Engineering", "Grant", "Multipass", "Outdoor 110-140", "", "1998", "current", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "32.24", "41.03", "", "", "86.5", "74.8", "", "54.7", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.9", "86.9", "", "", "", "", "87.1"]} -{"pcdb_id": 8421, "brand_name": "Vaillant", "model_name": "Ecomax", "model_qualifier": "828/2E", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 56.0, "output_kw_max": 22.4, "final_year_of_manufacture": 2010, "raw": ["008421", "000031", "0", "2010/Jan/28 08:31", "Vaillant", "Vaillant", "Ecomax", "828/2E", "VUW 286/2E-C", "2001", "2010", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "22.4", "22.4", "", "", "88.2", "79.6", "", "56.0", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.0", "96.5", "", "", "", "", "95.3"]} -{"pcdb_id": 8422, "brand_name": "Vaillant", "model_name": "Ecomax", "model_qualifier": "824/2E", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 56.0, "output_kw_max": 18.4, "final_year_of_manufacture": 2010, "raw": ["008422", "000031", "0", "2010/Jan/28 08:17", "Vaillant", "Vaillant", "Ecomax", "824/2E", "VUW 246/2E-C", "2001", "2010", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "18.4", "18.4", "", "", "88.3", "79.7", "", "56.0", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.0", "96.7", "", "", "", "", "95.4"]} -{"pcdb_id": 8423, "brand_name": "Vaillant", "model_name": "Ecomax", "model_qualifier": "622/2E", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 22.4, "final_year_of_manufacture": 2010, "raw": ["008423", "000031", "0", "2012/Mar/27 10:12", "Vaillant", "Vaillant", "Ecomax", "622/2E", "VU GB 246/2E-C", "2001", "2010", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "22.4", "22.4", "", "", "88.2", "79.2", "", "57.9", "", "2", "", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.0", "96.5", "", "", "", "", "95.3"]} -{"pcdb_id": 8424, "brand_name": "Vaillant", "model_name": "Ecomax", "model_qualifier": "618/2E", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 18.4, "final_year_of_manufacture": 2010, "raw": ["008424", "000031", "0", "2012/Mar/27 10:12", "Vaillant", "Vaillant", "Ecomax", "618/2E", "VU GB 196/2E", "2001", "2010", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18.4", "18.4", "", "", "88.3", "79.3", "", "57.9", "", "2", "", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.0", "96.7", "", "", "", "", "95.4"]} -{"pcdb_id": 8425, "brand_name": "Vaillant", "model_name": "Ecomax", "model_qualifier": "613/2E", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 13.5, "final_year_of_manufacture": 2010, "raw": ["008425", "000031", "0", "2012/Mar/27 10:12", "Vaillant", "Vaillant", "Ecomax", "613/2E", "VU GB 126/2E", "2001", "2010", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "13.5", "13.5", "", "", "88.2", "79.2", "", "57.9", "", "2", "", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.0", "96.6", "", "", "", "", "95.3"]} -{"pcdb_id": 8426, "brand_name": "Ferroli", "model_name": "Arena 30 A", "model_qualifier": "Mk2", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 32.4, "final_year_of_manufacture": 2005, "raw": ["008426", "000097", "0", "2012/Mar/27 10:12", "Ferroli SpA", "Ferroli", "Arena 30 A", "Mk2", "", "2001", "2005", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "32.4", "32.4", "", "", "88.2", "79.2", "", "57.8", "", "2", "", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.4", "97.0", "", "", "", "", "95.4"]} -{"pcdb_id": 8427, "brand_name": "Ferroli", "model_name": "Arena 30 C", "model_qualifier": "Mk2", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 55.9, "output_kw_max": 32.4, "final_year_of_manufacture": 2005, "raw": ["008427", "000097", "0", "2009/Apr/28 16:15", "Ferroli SpA", "Ferroli", "Arena 30 C", "Mk2", "", "2001", "2005", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "32.4", "32.4", "", "", "88.2", "79.6", "", "55.9", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.4", "97.0", "", "", "", "", "95.4"]} -{"pcdb_id": 8429, "brand_name": "Boulter", "model_name": "Classic", "model_qualifier": "50/70 A System", "winter_efficiency_pct": 86.1, "summer_efficiency_pct": 74.4, "comparative_hot_water_efficiency_pct": 54.3, "output_kw_max": 20.5, "final_year_of_manufacture": 2005, "raw": ["008429", "000041", "0", "2012/Mar/27 10:12", "Boulter Boilers", "Boulter", "Classic", "50/70 A System", "", "2001", "2005", "4", "1", "1", "1", "0", "", "", "1", "3", "2", "14.5", "20.5", "", "", "86.1", "74.4", "", "54.3", "", "2", "", "", "201", "1", "1", "115", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.6", "86.5", "", "", "", "", "86.3"]} -{"pcdb_id": 8430, "brand_name": "Boulter", "model_name": "Camray 5", "model_qualifier": "Combi 55", "winter_efficiency_pct": 84.7, "summer_efficiency_pct": 76.6, "comparative_hot_water_efficiency_pct": 36.0, "output_kw_max": 16.12, "final_year_of_manufacture": null, "raw": ["008430", "000041", "0", "2024/Jan/31 10:17", "Boulter Boilers", "Boulter", "Camray 5", "Combi 55", "", "2001", "current", "4", "1", "1", "2", "0", "", "", "1", "3", "2", "", "16.12", "", "", "84.7", "76.6", "", "36.0", "", "2", "", "", "203", "1", "1", "155", "0", "1", "1", "0", "40", "0", "15", "3", "82", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.0", "87.0", "", "", "", "", "87.0"]} -{"pcdb_id": 8431, "brand_name": "Boulter", "model_name": "Classic", "model_qualifier": "50/70 A", "winter_efficiency_pct": 86.1, "summer_efficiency_pct": 74.4, "comparative_hot_water_efficiency_pct": 54.3, "output_kw_max": 20.5, "final_year_of_manufacture": 2005, "raw": ["008431", "000041", "0", "2012/Mar/27 10:12", "Boulter Boilers", "Boulter", "Classic", "50/70 A", "", "2001", "2005", "4", "1", "1", "1", "0", "", "", "1", "3", "2", "14.5", "20.5", "", "", "86.1", "74.4", "", "54.3", "", "2", "", "", "201", "1", "1", "115", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.6", "86.5", "", "", "", "", "86.3"]} -{"pcdb_id": 8435, "brand_name": "Boulter", "model_name": "Camray 5 Wall Hung", "model_qualifier": "50/70 Internal", "winter_efficiency_pct": 86.4, "summer_efficiency_pct": 74.7, "comparative_hot_water_efficiency_pct": 54.6, "output_kw_max": 20.5, "final_year_of_manufacture": null, "raw": ["008435", "000041", "0", "2012/Mar/27 10:12", "Boulter Boilers", "Boulter", "Camray 5 Wall Hung", "50/70 Internal", "", "2001", "current", "4", "2", "1", "1", "0", "", "", "1", "3", "2", "14.5", "20.5", "", "", "86.4", "74.7", "", "54.6", "", "2", "", "", "201", "1", "1", "170", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.6", "87.7", "", "", "", "", "87.3"]} -{"pcdb_id": 8437, "brand_name": "Ideal", "model_name": "icos system", "model_qualifier": "m3080", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 23.4, "final_year_of_manufacture": 2004, "raw": ["008437", "000008", "0", "2012/Mar/27 10:12", "Ideal Boilers", "Ideal", "icos system", "m3080", "41-391-52", "2001", "2004", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "23.4", "23.4", "", "", "88.1", "79.1", "", "57.8", "", "2", "", "", "102", "1", "2", "148", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "97.1", "", "", "", "", "95.4"]} -{"pcdb_id": 8438, "brand_name": "Ideal", "model_name": "icos", "model_qualifier": "m3080", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 23.4, "final_year_of_manufacture": 2004, "raw": ["008438", "000008", "0", "2012/Mar/27 10:12", "Ideal boilers", "Ideal", "icos", "m3080", "41-391-49", "2001", "2004", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "23.4", "23.4", "", "", "88.1", "79.1", "", "57.8", "", "2", "", "", "102", "1", "2", "38", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "97.1", "", "", "", "", "95.4"]} -{"pcdb_id": 8439, "brand_name": "Ideal", "model_name": "isar", "model_qualifier": "m30100", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 55.9, "output_kw_max": 23.4, "final_year_of_manufacture": 2004, "raw": ["008439", "000008", "0", "2006/Jan/17 12:55", "Ideal boilers", "Ideal", "isar", "m30100", "47-348-15", "2001", "2004", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "23.4", "23.4", "", "", "88.1", "79.5", "", "55.9", "", "2", "", "", "104", "1", "2", "148", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "97.1", "", "", "", "", "95.4"]} -{"pcdb_id": 8440, "brand_name": "Potterton", "model_name": "Performa", "model_qualifier": "24", "winter_efficiency_pct": 79.5, "summer_efficiency_pct": 69.4, "comparative_hot_water_efficiency_pct": 48.8, "output_kw_max": 24.0, "final_year_of_manufacture": 2006, "raw": ["008440", "000005", "0", "2006/Nov/21 09:59", "Baxi Potterton", "Potterton", "Performa", "24", "47-393-06", "2001", "2006", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "24", "24", "", "", "79.5", "69.4", "", "48.8", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.2", "79.2", "", "", "", "", "79.8"]} -{"pcdb_id": 8441, "brand_name": "Potterton", "model_name": "Performa", "model_qualifier": "28", "winter_efficiency_pct": 79.0, "summer_efficiency_pct": 68.9, "comparative_hot_water_efficiency_pct": 48.5, "output_kw_max": 29.4, "final_year_of_manufacture": 2011, "raw": ["008441", "000005", "0", "2013/May/07 10:03", "Baxi Potterton", "Potterton", "Performa", "28", "47-393-07", "2001", "2011", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "29.4", "29.4", "", "", "79.0", "68.9", "", "48.5", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.2", "79.3", "", "", "", "", "79.6"]} -{"pcdb_id": 8442, "brand_name": "Potterton", "model_name": "Performa", "model_qualifier": "28i", "winter_efficiency_pct": 79.0, "summer_efficiency_pct": 68.9, "comparative_hot_water_efficiency_pct": 48.5, "output_kw_max": 29.4, "final_year_of_manufacture": 2006, "raw": ["008442", "000005", "0", "2006/Nov/21 10:05", "Baxi Potterton", "Potterton", "Performa", "28i", "47-393-08", "2001", "2006", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "29.4", "29.4", "", "", "79.0", "68.9", "", "48.5", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.2", "79.3", "", "", "", "", "79.6"]} -{"pcdb_id": 8443, "brand_name": "Boulter", "model_name": "Camray 5", "model_qualifier": "65/90A", "winter_efficiency_pct": 86.1, "summer_efficiency_pct": 74.4, "comparative_hot_water_efficiency_pct": 54.3, "output_kw_max": 26.4, "final_year_of_manufacture": null, "raw": ["008443", "000041", "0", "2012/Mar/27 10:12", "Boulter Boilers", "Boulter", "Camray 5", "65/90A", "", "2001", "current", "4", "1", "1", "1", "0", "", "", "1", "3", "2", "19", "26.4", "", "", "86.1", "74.4", "", "54.3", "", "2", "", "", "201", "1", "1", "145", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.0", "88.2", "", "", "", "", "87.6"]} -{"pcdb_id": 8445, "brand_name": "Boulter", "model_name": "Camray 5", "model_qualifier": "65/90A Utility", "winter_efficiency_pct": 86.1, "summer_efficiency_pct": 74.4, "comparative_hot_water_efficiency_pct": 54.3, "output_kw_max": 26.4, "final_year_of_manufacture": null, "raw": ["008445", "000041", "0", "2012/Mar/27 10:12", "Boulter Boilers", "Boulter", "Camray 5", "65/90A Utility", "", "2001", "current", "4", "1", "1", "1", "0", "", "", "1", "3", "2", "19", "26.4", "", "", "86.1", "74.4", "", "54.3", "", "2", "", "", "201", "1", "1", "145", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.0", "88.2", "", "", "", "", "87.6"]} -{"pcdb_id": 8447, "brand_name": "Boulter", "model_name": "Camray 5", "model_qualifier": "65/90A System", "winter_efficiency_pct": 86.1, "summer_efficiency_pct": 74.4, "comparative_hot_water_efficiency_pct": 54.3, "output_kw_max": 26.4, "final_year_of_manufacture": null, "raw": ["008447", "000041", "0", "2012/Mar/27 10:12", "Boulter Boilers", "Boulter", "Camray 5", "65/90A System", "", "2001", "current", "4", "1", "1", "1", "0", "", "", "1", "3", "2", "19", "26.4", "", "", "86.1", "74.4", "", "54.3", "", "2", "", "", "201", "1", "1", "145", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.0", "88.2", "", "", "", "", "87.6"]} -{"pcdb_id": 8449, "brand_name": "Boulter", "model_name": "Bonus", "model_qualifier": "65/90A", "winter_efficiency_pct": 86.1, "summer_efficiency_pct": 74.4, "comparative_hot_water_efficiency_pct": 54.3, "output_kw_max": 26.4, "final_year_of_manufacture": 2005, "raw": ["008449", "000041", "0", "2012/Mar/27 10:12", "Boulter Boilers", "Boulter", "Bonus", "65/90A", "", "2001", "2005", "4", "1", "1", "1", "0", "", "", "1", "3", "2", "19", "26.4", "", "", "86.1", "74.4", "", "54.3", "", "2", "", "", "201", "1", "1", "145", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.0", "88.2", "", "", "", "", "87.6"]} -{"pcdb_id": 8451, "brand_name": "Boulter", "model_name": "Camray 5", "model_qualifier": "Combi 90A", "winter_efficiency_pct": 84.2, "summer_efficiency_pct": 76.1, "comparative_hot_water_efficiency_pct": 35.7, "output_kw_max": 26.4, "final_year_of_manufacture": null, "raw": ["008451", "000041", "0", "2024/Jan/31 10:17", "Boulter Boilers", "Boulter", "Camray 5", "Combi 90A", "", "2001", "current", "4", "1", "1", "2", "0", "", "", "1", "3", "2", "26.4", "26.4", "", "", "84.2", "76.1", "", "35.7", "", "2", "", "", "203", "1", "1", "145", "0", "1", "1", "0", "40", "0", "15", "3", "82", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.0", "88.2", "", "", "", "", "87.6"]} -{"pcdb_id": 8453, "brand_name": "Boulter", "model_name": "Camray 5", "model_qualifier": "Combi 70A", "winter_efficiency_pct": 84.2, "summer_efficiency_pct": 76.1, "comparative_hot_water_efficiency_pct": 35.7, "output_kw_max": 20.5, "final_year_of_manufacture": null, "raw": ["008453", "000041", "0", "2024/Jan/31 10:17", "Boulter Boilers", "Boulter", "Camray 5", "Combi 70A", "", "2001", "current", "4", "1", "1", "2", "0", "", "", "1", "3", "2", "20.5", "20.5", "", "", "84.2", "76.1", "", "35.7", "", "2", "", "", "203", "1", "1", "145", "0", "1", "1", "0", "40", "0", "15", "3", "82", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.0", "88.2", "", "", "", "", "87.6"]} -{"pcdb_id": 8455, "brand_name": "Boulter", "model_name": "Classic", "model_qualifier": "70/90A", "winter_efficiency_pct": 85.8, "summer_efficiency_pct": 74.1, "comparative_hot_water_efficiency_pct": 54.1, "output_kw_max": 26.4, "final_year_of_manufacture": 2005, "raw": ["008455", "000041", "0", "2012/Mar/27 10:12", "Boulter Boilers", "Boulter", "Classic", "70/90A", "", "2001", "2005", "4", "1", "1", "1", "0", "", "", "1", "3", "2", "20.5", "26.4", "", "", "85.8", "74.1", "", "54.1", "", "2", "", "", "201", "1", "1", "115", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "84.9", "86.8", "", "", "", "", "86.4"]} -{"pcdb_id": 8457, "brand_name": "Boulter", "model_name": "Classic", "model_qualifier": "70/90A System", "winter_efficiency_pct": 85.8, "summer_efficiency_pct": 74.1, "comparative_hot_water_efficiency_pct": 54.1, "output_kw_max": 26.4, "final_year_of_manufacture": 2005, "raw": ["008457", "000041", "0", "2012/Mar/27 10:12", "Boulter Boilers", "Boulter", "Classic", "70/90A System", "", "2001", "2005", "4", "1", "1", "1", "0", "", "", "1", "3", "2", "20.5", "26.4", "", "", "85.8", "74.1", "", "54.1", "", "2", "", "", "201", "1", "1", "115", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "84.9", "86.8", "", "", "", "", "86.4"]} -{"pcdb_id": 8460, "brand_name": "Boulter", "model_name": "Camray 5", "model_qualifier": "150/200G", "winter_efficiency_pct": 86.6, "summer_efficiency_pct": 74.9, "comparative_hot_water_efficiency_pct": 54.7, "output_kw_max": 58.6, "final_year_of_manufacture": 2005, "raw": ["008460", "000041", "0", "2012/Mar/27 10:12", "Boulter Boilers", "Boulter", "Camray 5", "150/200G", "", "2000", "2005", "4", "1", "1", "1", "0", "", "", "1", "3", "2", "43.9", "58.6", "", "", "86.6", "74.9", "", "54.7", "", "2", "", "", "201", "1", "1", "150", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.2", "87.0", "", "", "", "", "87.1"]} -{"pcdb_id": 8461, "brand_name": "Boulter", "model_name": "Classic", "model_qualifier": "95/130 System", "winter_efficiency_pct": 86.6, "summer_efficiency_pct": 74.9, "comparative_hot_water_efficiency_pct": 54.7, "output_kw_max": 38.1, "final_year_of_manufacture": 2005, "raw": ["008461", "000041", "0", "2012/Mar/27 10:12", "Boulter Boilers", "Boulter", "Classic", "95/130 System", "", "2000", "2005", "4", "1", "1", "1", "0", "", "", "1", "3", "2", "27.8", "38.1", "", "", "86.6", "74.9", "", "54.7", "", "2", "", "", "201", "1", "1", "145", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.0", "88.9", "", "", "", "", "88.4"]} -{"pcdb_id": 8463, "brand_name": "Chaffoteaux et Maury", "model_name": "Britony Combi SE80", "model_qualifier": "Atac 24FF", "winter_efficiency_pct": 79.6, "summer_efficiency_pct": 69.5, "comparative_hot_water_efficiency_pct": 48.9, "output_kw_max": 24.0, "final_year_of_manufacture": 2007, "raw": ["008463", "000010", "0", "2007/Jun/18 09:15", "Chaffoteaux et Maury", "Chaffoteaux et Maury", "Britony Combi SE80", "Atac 24FF", "GC No 47 980 16", "2001", "2007", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "24", "24", "", "", "79.6", "69.5", "", "48.9", "", "2", "", "", "104", "1", "2", "150", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.6", "78.9", "", "", "", "", "79.6"]} -{"pcdb_id": 8464, "brand_name": "Chaffoteaux et Maury", "model_name": "Britony Combi SE100", "model_qualifier": "Atac 28FF", "winter_efficiency_pct": 79.3, "summer_efficiency_pct": 69.2, "comparative_hot_water_efficiency_pct": 48.7, "output_kw_max": 28.0, "final_year_of_manufacture": 2007, "raw": ["008464", "000010", "0", "2007/Jun/18 09:16", "Chaffoteaux et Maury", "Chaffoteaux et Maury", "Britony Combi SE100", "Atac 28FF", "GC No 47 980 17", "2001", "2007", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "28", "28", "", "", "79.3", "69.2", "", "48.7", "", "2", "", "", "104", "1", "2", "150", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.5", "78.5", "", "", "", "", "79.2"]} -{"pcdb_id": 8465, "brand_name": "Biasi", "model_name": "Parva", "model_qualifier": "M90 28S", "winter_efficiency_pct": 79.2, "summer_efficiency_pct": 69.1, "comparative_hot_water_efficiency_pct": 48.6, "output_kw_max": 28.0, "final_year_of_manufacture": null, "raw": ["008465", "000208", "0", "2006/Jan/17 12:31", "Biasi SpA", "Biasi", "Parva", "M90 28S", "47-970-14", "2001", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "28", "28", "", "", "79.2", "69.1", "", "48.6", "", "2", "", "", "104", "1", "2", "170", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.2", "78.6", "", "", "", "", "79.3"]} -{"pcdb_id": 8466, "brand_name": "Biasi", "model_name": "Parva", "model_qualifier": "M90 24S", "winter_efficiency_pct": 79.1, "summer_efficiency_pct": 69.0, "comparative_hot_water_efficiency_pct": 48.5, "output_kw_max": 24.0, "final_year_of_manufacture": 2007, "raw": ["008466", "000208", "0", "2008/May/22 11:40", "Biasi SpA", "Biasi", "Parva", "M90 24S", "47-970-13", "2001", "2007", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "24", "24", "", "", "79.1", "69.0", "", "48.5", "", "2", "", "", "104", "1", "2", "150", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.3", "78.4", "", "", "", "", "79.1"]} -{"pcdb_id": 8467, "brand_name": "Glow-worm", "model_name": "Saunier Duval SD30e", "model_qualifier": "A", "winter_efficiency_pct": 80.1, "summer_efficiency_pct": 70.0, "comparative_hot_water_efficiency_pct": 49.2, "output_kw_max": 28.2, "final_year_of_manufacture": 2003, "raw": ["008467", "000206", "0", "2006/Jan/17 12:55", "Glow-worm", "Glow-worm", "Saunier Duval SD30e", "A", "GC 47 920 16", "1999", "2003", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "28.2", "28.2", "", "", "80.1", "70.0", "", "49.2", "", "2", "", "", "104", "1", "2", "150", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.4", "80.2", "", "", "", "", "80.6"]} -{"pcdb_id": 8468, "brand_name": "Glow-worm", "model_name": "Saunier Duval SB30e", "model_qualifier": "A", "winter_efficiency_pct": 80.3, "summer_efficiency_pct": 69.6, "comparative_hot_water_efficiency_pct": 50.8, "output_kw_max": 28.2, "final_year_of_manufacture": 2003, "raw": ["008468", "000206", "0", "2012/Mar/27 10:12", "Glow-worm", "Glow-worm", "Saunier Duval SB30e", "A", "GC 41 920 31", "1999", "2003", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "28.2", "28.2", "", "", "80.3", "69.6", "", "50.8", "", "2", "", "", "102", "1", "2", "150", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.4", "80.2", "", "", "", "", "80.6"]} -{"pcdb_id": 8469, "brand_name": "Glow-worm", "model_name": "Compact 60 System", "model_qualifier": "A", "winter_efficiency_pct": 80.5, "summer_efficiency_pct": 69.8, "comparative_hot_water_efficiency_pct": 50.9, "output_kw_max": 17.58, "final_year_of_manufacture": 2003, "raw": ["008469", "000207", "0", "2012/Mar/27 10:12", "Glow-worm", "Glow-worm", "Compact 60 System", "A", "GC 41-047-27", "1999", "2003", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "17.58", "17.58", "", "", "80.5", "69.8", "", "50.9", "", "2", "", "", "102", "1", "2", "150", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.5", "80.4", "", "", "", "", "80.8"]} -{"pcdb_id": 8470, "brand_name": "Glow-worm", "model_name": "Compact 80e", "model_qualifier": "A", "winter_efficiency_pct": 80.4, "summer_efficiency_pct": 70.3, "comparative_hot_water_efficiency_pct": 49.4, "output_kw_max": 23.45, "final_year_of_manufacture": 2003, "raw": ["008470", "000207", "0", "2006/Jan/17 12:55", "Glow-worm", "Glow-worm", "Compact 80e", "A", "GC 47 047 07A", "1999", "2003", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "23.45", "23.45", "", "", "80.4", "70.3", "", "49.4", "", "2", "", "", "104", "1", "2", "150", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.6", "80.5", "", "", "", "", "80.9"]} -{"pcdb_id": 8471, "brand_name": "Glow-worm", "model_name": "Compact 100 System", "model_qualifier": "A", "winter_efficiency_pct": 80.3, "summer_efficiency_pct": 69.6, "comparative_hot_water_efficiency_pct": 50.8, "output_kw_max": 28.2, "final_year_of_manufacture": 2003, "raw": ["008471", "000207", "0", "2012/Mar/27 10:12", "Glow-worm", "Glow-worm", "Compact 100 System", "A", "GC 41 047 26", "1999", "2003", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "28.2", "28.2", "", "", "80.3", "69.6", "", "50.8", "", "2", "", "", "102", "1", "2", "150", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.4", "80.2", "", "", "", "", "80.6"]} -{"pcdb_id": 8472, "brand_name": "Glow-worm", "model_name": "Compact 100e", "model_qualifier": "A", "winter_efficiency_pct": 80.1, "summer_efficiency_pct": 70.0, "comparative_hot_water_efficiency_pct": 49.2, "output_kw_max": 28.2, "final_year_of_manufacture": 2003, "raw": ["008472", "000207", "0", "2006/Jan/17 12:55", "Glow-worm", "Glow-worm", "Compact 100e", "A", "GC 47 047 08A", "1999", "2003", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "28.2", "28.2", "", "", "80.1", "70.0", "", "49.2", "", "2", "", "", "104", "1", "2", "150", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.4", "80.2", "", "", "", "", "80.6"]} -{"pcdb_id": 8473, "brand_name": "Clyde", "model_name": "GO4E", "model_qualifier": "", "winter_efficiency_pct": 79.6, "summer_efficiency_pct": 69.5, "comparative_hot_water_efficiency_pct": 50.8, "output_kw_max": 33.5, "final_year_of_manufacture": null, "raw": ["008473", "000012", "0", "2012/Mar/27 10:12", "Clyde Combustions", "Clyde", "GO4E", "", "", "", "current", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "33.5", "33.5", "", "", "79.6", "69.5", "", "50.8", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.3", "81.1", "", "", "", "", "81.1"]} -{"pcdb_id": 8474, "brand_name": "Clyde", "model_name": "GO5E", "model_qualifier": "", "winter_efficiency_pct": 79.7, "summer_efficiency_pct": 69.6, "comparative_hot_water_efficiency_pct": 50.8, "output_kw_max": 43.6, "final_year_of_manufacture": null, "raw": ["008474", "000012", "0", "2012/Mar/27 10:12", "Clyde Combustions", "Clyde", "GO5E", "", "", "1996", "current", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "43.6", "43.6", "", "", "79.7", "69.6", "", "50.8", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.4", "81.2", "", "", "", "", "81.2"]} -{"pcdb_id": 8475, "brand_name": "Clyde", "model_name": "GO6E", "model_qualifier": "", "winter_efficiency_pct": 79.6, "summer_efficiency_pct": 69.5, "comparative_hot_water_efficiency_pct": 50.8, "output_kw_max": 55.0, "final_year_of_manufacture": null, "raw": ["008475", "000012", "0", "2012/Mar/27 10:12", "Clyde Combustions", "Clyde", "GO6E", "", "", "", "current", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "55", "55", "", "", "79.6", "69.5", "", "50.8", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.3", "81.2", "", "", "", "", "81.2"]} -{"pcdb_id": 8476, "brand_name": "Clyde", "model_name": "GO7E", "model_qualifier": "", "winter_efficiency_pct": 79.6, "summer_efficiency_pct": 69.5, "comparative_hot_water_efficiency_pct": 50.8, "output_kw_max": 63.5, "final_year_of_manufacture": null, "raw": ["008476", "000012", "0", "2012/Mar/27 10:12", "Clyde Combustions", "Clyde", "GO7E", "", "", "", "current", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "63.5", "63.5", "", "", "79.6", "69.5", "", "50.8", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.2", "81.2", "", "", "", "", "81.2"]} -{"pcdb_id": 8478, "brand_name": "Clyde", "model_name": "CW60", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 58.9, "final_year_of_manufacture": null, "raw": ["008478", "000012", "0", "2012/Mar/27 10:12", "Clyde Combustions", "Clyde", "CW60", "", "", "", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "58.9", "58.9", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "84", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.4", "97.6", "", "", "", "", "95.8"]} -{"pcdb_id": 8479, "brand_name": "Clyde", "model_name": "CW45", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 43.7, "final_year_of_manufacture": null, "raw": ["008479", "000012", "0", "2012/Mar/27 10:12", "Clyde Combustions", "Clyde", "CW45", "", "", "", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "43.7", "43.7", "", "", "88.1", "79.1", "", "57.8", "", "2", "", "", "102", "1", "2", "51", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.4", "97.2", "", "", "", "", "95.4"]} -{"pcdb_id": 8480, "brand_name": "Boulter", "model_name": "Camray 5", "model_qualifier": "95/130A System", "winter_efficiency_pct": 86.4, "summer_efficiency_pct": 74.7, "comparative_hot_water_efficiency_pct": 54.6, "output_kw_max": 38.1, "final_year_of_manufacture": 2005, "raw": ["008480", "000041", "0", "2012/Mar/27 10:12", "Boulter Boilers", "Boulter", "Camray 5", "95/130A System", "", "2001", "2005", "4", "1", "1", "1", "0", "", "", "1", "3", "2", "27.8", "38.1", "", "", "86.4", "74.7", "", "54.6", "", "2", "", "", "201", "1", "1", "145", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.0", "86.8", "", "", "", "", "86.6"]} -{"pcdb_id": 8482, "brand_name": "Boulter", "model_name": "Camray 5", "model_qualifier": "95/130A Utility", "winter_efficiency_pct": 86.4, "summer_efficiency_pct": 74.7, "comparative_hot_water_efficiency_pct": 54.6, "output_kw_max": 38.1, "final_year_of_manufacture": null, "raw": ["008482", "000041", "0", "2012/Mar/27 10:12", "Boulter Boilers", "Boulter", "Camray 5", "95/130A Utility", "", "2001", "current", "4", "1", "1", "1", "0", "", "", "1", "3", "2", "27.8", "38.1", "", "", "86.4", "74.7", "", "54.6", "", "2", "", "", "201", "1", "1", "145", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.0", "86.8", "", "", "", "", "86.6"]} -{"pcdb_id": 8484, "brand_name": "Boulter", "model_name": "Camray 5", "model_qualifier": "95/130A", "winter_efficiency_pct": 86.4, "summer_efficiency_pct": 74.7, "comparative_hot_water_efficiency_pct": 54.6, "output_kw_max": 38.1, "final_year_of_manufacture": null, "raw": ["008484", "000041", "0", "2012/Mar/27 10:12", "Boulter Boilers", "Boulter", "Camray 5", "95/130A", "", "2001", "current", "4", "1", "1", "1", "0", "", "", "1", "3", "2", "27.8", "38.1", "", "", "86.4", "74.7", "", "54.6", "", "2", "", "", "201", "1", "1", "145", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.0", "86.8", "", "", "", "", "86.6"]} -{"pcdb_id": 8487, "brand_name": "Merlin", "model_name": "45/65 BL", "model_qualifier": "", "winter_efficiency_pct": 84.8, "summer_efficiency_pct": 73.1, "comparative_hot_water_efficiency_pct": 53.4, "output_kw_max": 19.0, "final_year_of_manufacture": null, "raw": ["008487", "000210", "0", "2012/Mar/27 10:12", "BH Associates", "Merlin", "45/65 BL", "", "", "1994", "current", "4", "1", "1", "1", "0", "", "", "1", "2", "1", "13.2", "19", "", "", "84.8", "73.1", "", "53.4", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.5", "84.1", "", "", "", "", "84.4"]} -{"pcdb_id": 8488, "brand_name": "Merlin", "model_name": "45/65 CF", "model_qualifier": "", "winter_efficiency_pct": 84.8, "summer_efficiency_pct": 73.1, "comparative_hot_water_efficiency_pct": 53.4, "output_kw_max": 19.0, "final_year_of_manufacture": null, "raw": ["008488", "000210", "0", "2012/Mar/27 10:12", "BH Associates", "Merlin", "45/65 CF", "", "", "1994", "current", "4", "1", "1", "1", "0", "", "", "1", "1", "1", "13.2", "19", "", "", "84.8", "73.1", "", "53.4", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.5", "84.1", "", "", "", "", "84.4"]} -{"pcdb_id": 8489, "brand_name": "Merlin", "model_name": "100/150 BF", "model_qualifier": "", "winter_efficiency_pct": 82.4, "summer_efficiency_pct": 70.7, "comparative_hot_water_efficiency_pct": 51.6, "output_kw_max": 44.0, "final_year_of_manufacture": null, "raw": ["008489", "000210", "0", "2012/Mar/27 10:12", "BH Associates", "Merlin", "100/150 BF", "", "", "1994", "current", "4", "1", "1", "1", "0", "", "", "1", "2", "1", "29.3", "44", "", "", "82.4", "70.7", "", "51.6", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.5", "82.3", "", "", "", "", "82.3"]} -{"pcdb_id": 8490, "brand_name": "Merlin", "model_name": "100/150 CF", "model_qualifier": "", "winter_efficiency_pct": 82.4, "summer_efficiency_pct": 70.7, "comparative_hot_water_efficiency_pct": 51.6, "output_kw_max": 44.0, "final_year_of_manufacture": null, "raw": ["008490", "000210", "0", "2012/Mar/27 10:12", "BH Associates", "Merlin", "100/150 CF", "", "", "1994", "current", "4", "1", "1", "1", "0", "", "", "1", "1", "1", "29.3", "44", "", "", "82.4", "70.7", "", "51.6", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.5", "82.3", "", "", "", "", "82.3"]} -{"pcdb_id": 8491, "brand_name": "Merlin", "model_name": "65/95 BL", "model_qualifier": "", "winter_efficiency_pct": 82.9, "summer_efficiency_pct": 71.2, "comparative_hot_water_efficiency_pct": 52.0, "output_kw_max": 27.8, "final_year_of_manufacture": null, "raw": ["008491", "000210", "0", "2012/Mar/27 10:12", "BH Associates", "Merlin", "65/95 BL", "", "", "1994", "current", "4", "1", "1", "1", "0", "", "", "1", "2", "1", "19", "27.8", "", "", "82.9", "71.2", "", "52.0", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "83.3", "82.5", "", "", "", "", "82.7"]} -{"pcdb_id": 8492, "brand_name": "Merlin", "model_name": "65/95 CF", "model_qualifier": "", "winter_efficiency_pct": 82.9, "summer_efficiency_pct": 71.2, "comparative_hot_water_efficiency_pct": 52.0, "output_kw_max": 27.8, "final_year_of_manufacture": null, "raw": ["008492", "000210", "0", "2012/Mar/27 10:12", "BH Associates", "Merlin", "65/95 CF", "", "", "1994", "current", "4", "1", "1", "1", "0", "", "", "1", "1", "1", "19", "27.8", "", "", "82.9", "71.2", "", "52.0", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "83.3", "82.5", "", "", "", "", "82.7"]} -{"pcdb_id": 8493, "brand_name": "Merlin", "model_name": "Internal Wall Hung", "model_qualifier": "40/65 BL", "winter_efficiency_pct": 81.9, "summer_efficiency_pct": 70.2, "comparative_hot_water_efficiency_pct": 51.3, "output_kw_max": 19.0, "final_year_of_manufacture": 2001, "raw": ["008493", "000210", "0", "2012/Mar/27 10:12", "BH Associates", "Merlin", "Internal Wall Hung", "40/65 BL", "", "1995", "2001", "4", "2", "1", "1", "0", "", "", "1", "2", "1", "11.7", "19", "", "", "81.9", "70.2", "", "51.3", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.5", "81.3", "", "", "", "", "81.6"]} -{"pcdb_id": 8494, "brand_name": "Merlin", "model_name": "Internal Wall Hung", "model_qualifier": "40/65 CF", "winter_efficiency_pct": 81.9, "summer_efficiency_pct": 70.2, "comparative_hot_water_efficiency_pct": 51.3, "output_kw_max": 19.0, "final_year_of_manufacture": null, "raw": ["008494", "000210", "0", "2012/Mar/27 10:12", "BH Associates", "Merlin", "Internal Wall Hung", "40/65 CF", "", "1995", "current", "4", "2", "1", "1", "0", "", "", "1", "1", "1", "11.7", "19", "", "", "81.9", "70.2", "", "51.3", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.5", "81.3", "", "", "", "", "81.6"]} -{"pcdb_id": 8495, "brand_name": "Merlin", "model_name": "Internal Wall Hung", "model_qualifier": "40/65 EXT", "winter_efficiency_pct": 81.9, "summer_efficiency_pct": 70.2, "comparative_hot_water_efficiency_pct": 51.3, "output_kw_max": 19.0, "final_year_of_manufacture": null, "raw": ["008495", "000210", "0", "2012/Mar/27 10:12", "BH Associates", "Merlin", "Internal Wall Hung", "40/65 EXT", "", "1997", "current", "4", "2", "2", "1", "0", "", "", "1", "1", "1", "11.7", "19", "", "", "81.9", "70.2", "", "51.3", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.5", "81.3", "", "", "", "", "81.6"]} -{"pcdb_id": 8496, "brand_name": "Worcester", "model_name": "24 CDi", "model_qualifier": "RSF-L", "winter_efficiency_pct": 81.4, "summer_efficiency_pct": 71.3, "comparative_hot_water_efficiency_pct": 50.2, "output_kw_max": 24.0, "final_year_of_manufacture": 2005, "raw": ["008496", "000035", "0", "2020/Sep/02 14:14", "Worcester Heat Systems", "Worcester", "24 CDi", "RSF-L", "47 311 31", "2001", "2005", "2", "2", "1", "2", "0", "", "", "1", "2", "2", "24", "24", "", "", "81.4", "71.3", "", "50.2", "", "2", "0", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "84.8", "80.5", "", "", "", "", "81.3"]} -{"pcdb_id": 8497, "brand_name": "Worcester", "model_name": "24 CDi", "model_qualifier": "RSF-L", "winter_efficiency_pct": 79.0, "summer_efficiency_pct": 68.9, "comparative_hot_water_efficiency_pct": 48.5, "output_kw_max": 24.0, "final_year_of_manufacture": 2005, "raw": ["008497", "000035", "0", "2020/Sep/02 14:14", "Worcester Heat Systems", "Worcester", "24 CDi", "RSF-L", "47 311 30", "2001", "2005", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "24", "24", "", "", "79.0", "68.9", "", "48.5", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.4", "78.1", "", "", "", "", "78.9"]} -{"pcdb_id": 8499, "brand_name": "Boulter", "model_name": "Camray 5 Wall Hung", "model_qualifier": "50/70 External", "winter_efficiency_pct": 86.4, "summer_efficiency_pct": 74.7, "comparative_hot_water_efficiency_pct": 54.6, "output_kw_max": 20.5, "final_year_of_manufacture": null, "raw": ["008499", "000041", "0", "2012/Mar/27 10:12", "Boulter Boilers", "Boulter", "Camray 5 Wall Hung", "50/70 External", "", "2001", "current", "4", "2", "2", "1", "0", "", "", "1", "2", "2", "14.5", "20.5", "", "", "86.4", "74.7", "", "54.6", "", "2", "", "", "201", "1", "1", "170", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.6", "87.7", "", "", "", "", "87.3"]} -{"pcdb_id": 8500, "brand_name": "Quantum", "model_name": "DB", "model_qualifier": "System Boiler", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 78.9, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 23.0, "final_year_of_manufacture": null, "raw": ["008500", "000205", "0", "2012/Mar/27 10:12", "Quantum Heating", "Quantum", "DB", "System Boiler", "", "2001", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "23", "23", "", "", "87.9", "78.9", "", "57.7", "", "2", "", "", "102", "1", "2", "85", "85", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.7", "96.8", "", "", "", "", "95.0"]} -{"pcdb_id": 8501, "brand_name": "Quantum", "model_name": "DB", "model_qualifier": "", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 78.9, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 23.0, "final_year_of_manufacture": null, "raw": ["008501", "000205", "0", "2012/Mar/27 10:12", "Quantum Heating", "Quantum", "DB", "", "", "2001", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "23", "23", "", "", "87.9", "78.9", "", "57.7", "", "2", "", "", "102", "1", "2", "85", "85", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.7", "96.8", "", "", "", "", "95.0"]} -{"pcdb_id": 8502, "brand_name": "Quantum", "model_name": "DB", "model_qualifier": "System Boiler", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 23.5, "final_year_of_manufacture": null, "raw": ["008502", "000205", "0", "2012/Mar/27 10:12", "Quantum Heating", "Quantum", "DB", "System Boiler", "", "2001", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "23.5", "23.5", "", "", "88.9", "79.9", "", "58.3", "", "2", "0", "", "102", "1", "2", "85", "85", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.5", "96.2", "", "", "", "", "95.0"]} -{"pcdb_id": 8503, "brand_name": "Quantum", "model_name": "DB", "model_qualifier": "", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 23.5, "final_year_of_manufacture": null, "raw": ["008503", "000205", "0", "2012/Mar/27 10:12", "Quantum Heating", "Quantum", "DB", "", "", "2001", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "23.5", "23.5", "", "", "88.9", "79.9", "", "58.3", "", "2", "0", "", "102", "1", "2", "85", "85", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.5", "96.2", "", "", "", "", "95.0"]} -{"pcdb_id": 8504, "brand_name": "Halstead", "model_name": "Best 70 db", "model_qualifier": "", "winter_efficiency_pct": 79.4, "summer_efficiency_pct": 69.3, "comparative_hot_water_efficiency_pct": 50.6, "output_kw_max": 20.5, "final_year_of_manufacture": 2006, "raw": ["008504", "000019", "0", "2012/Mar/27 10:12", "Halstead Boilers", "Halstead", "Best 70 db", "", "DBX70", "2001", "2006", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "0", "20.5", "", "", "79.4", "69.3", "", "50.6", "", "2", "", "", "101", "1", "1", "45", "5", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "80.6", "81.4", "", "", "", "", "81.2"]} -{"pcdb_id": 8505, "brand_name": "Halstead", "model_name": "Best 60 db", "model_qualifier": "", "winter_efficiency_pct": 80.1, "summer_efficiency_pct": 70.0, "comparative_hot_water_efficiency_pct": 51.1, "output_kw_max": 19.4, "final_year_of_manufacture": 2006, "raw": ["008505", "000019", "0", "2012/Mar/27 10:12", "Halstead Boilers", "Halstead", "Best 60 db", "", "DBX60", "2001", "2006", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "0", "19.4", "", "", "80.1", "70.0", "", "51.1", "", "2", "", "", "101", "1", "1", "45", "5", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.5", "81.8", "", "", "", "", "81.8"]} -{"pcdb_id": 8506, "brand_name": "Halstead", "model_name": "Best 50 db", "model_qualifier": "", "winter_efficiency_pct": 79.0, "summer_efficiency_pct": 68.9, "comparative_hot_water_efficiency_pct": 50.3, "output_kw_max": 14.6, "final_year_of_manufacture": 2006, "raw": ["008506", "000019", "0", "2012/Mar/27 10:12", "Halstead Boilers", "Halstead", "Best 50 db", "", "DBX50", "2001", "2006", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "0", "14.6", "", "", "79.0", "68.9", "", "50.3", "", "2", "", "", "101", "1", "1", "45", "5", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "80.5", "80.6", "", "", "", "", "80.6"]} -{"pcdb_id": 8507, "brand_name": "Halstead", "model_name": "Best 40 db", "model_qualifier": "", "winter_efficiency_pct": 79.5, "summer_efficiency_pct": 69.4, "comparative_hot_water_efficiency_pct": 50.7, "output_kw_max": 11.7, "final_year_of_manufacture": 2006, "raw": ["008507", "000019", "0", "2012/Mar/27 10:12", "Halstead Boilers", "Halstead", "Best 40 db", "", "DBX40", "2001", "2006", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "0", "11.7", "", "", "79.5", "69.4", "", "50.7", "", "2", "", "", "101", "1", "1", "45", "5", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.3", "81.0", "", "", "", "", "81.1"]} -{"pcdb_id": 8508, "brand_name": "Halstead", "model_name": "Best 30 db", "model_qualifier": "", "winter_efficiency_pct": 79.0, "summer_efficiency_pct": 68.9, "comparative_hot_water_efficiency_pct": 50.3, "output_kw_max": 8.8, "final_year_of_manufacture": 2006, "raw": ["008508", "000019", "0", "2012/Mar/27 10:12", "Halstead Boilers", "Halstead", "Best 30 db", "", "DBX30", "2001", "2006", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "0", "8.8", "", "", "79.0", "68.9", "", "50.3", "", "2", "", "", "101", "1", "1", "45", "5", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "80.7", "80.5", "", "", "", "", "80.5"]} -{"pcdb_id": 8509, "brand_name": "Halstead", "model_name": "Wickes", "model_qualifier": "LW 40 ci", "winter_efficiency_pct": 79.5, "summer_efficiency_pct": 69.4, "comparative_hot_water_efficiency_pct": 50.7, "output_kw_max": 11.7, "final_year_of_manufacture": 2006, "raw": ["008509", "000019", "0", "2012/Mar/27 10:12", "Halstead Boilers", "Halstead", "Wickes", "LW 40 ci", "DBXW40", "2001", "2006", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "0", "11.7", "", "", "79.5", "69.4", "", "50.7", "", "2", "", "", "101", "1", "1", "45", "5", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.3", "81.0", "", "", "", "", "81.1"]} -{"pcdb_id": 8510, "brand_name": "Halstead", "model_name": "Wickes", "model_qualifier": "LW 50 ci", "winter_efficiency_pct": 79.0, "summer_efficiency_pct": 68.9, "comparative_hot_water_efficiency_pct": 50.3, "output_kw_max": 14.6, "final_year_of_manufacture": 2006, "raw": ["008510", "000019", "0", "2012/Mar/27 10:12", "Halstead Boilers", "Halstead", "Wickes", "LW 50 ci", "DBXW50", "2001", "2006", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "0", "14.6", "", "", "79.0", "68.9", "", "50.3", "", "2", "", "", "101", "1", "1", "45", "5", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "80.5", "80.6", "", "", "", "", "80.6"]} -{"pcdb_id": 8511, "brand_name": "Halstead", "model_name": "Wickes", "model_qualifier": "LW 60 ci", "winter_efficiency_pct": 80.1, "summer_efficiency_pct": 70.0, "comparative_hot_water_efficiency_pct": 51.1, "output_kw_max": 17.6, "final_year_of_manufacture": 2006, "raw": ["008511", "000019", "0", "2012/Mar/27 10:12", "Halstead Boilers", "Halstead", "Wickes", "LW 60 ci", "DBX60", "2001", "2006", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "0", "17.6", "", "", "80.1", "70.0", "", "51.1", "", "2", "", "", "101", "1", "1", "45", "5", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.5", "81.8", "", "", "", "", "81.8"]} -{"pcdb_id": 8512, "brand_name": "Halstead", "model_name": "Finest", "model_qualifier": "fx", "winter_efficiency_pct": 80.2, "summer_efficiency_pct": 70.1, "comparative_hot_water_efficiency_pct": 49.3, "output_kw_max": 26.4, "final_year_of_manufacture": 2006, "raw": ["008512", "000019", "0", "2008/Feb/19 10:12", "Halstead Boilers", "Halstead", "Finest", "fx", "", "2001", "2006", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "26.4", "26.4", "", "", "80.2", "70.1", "", "49.3", "", "2", "", "", "104", "1", "2", "150", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.5", "81.3", "", "", "", "", "81.3"]} -{"pcdb_id": 8513, "brand_name": "Halstead", "model_name": "Finest Gold", "model_qualifier": "fgx", "winter_efficiency_pct": 80.2, "summer_efficiency_pct": 70.1, "comparative_hot_water_efficiency_pct": 49.3, "output_kw_max": 30.0, "final_year_of_manufacture": 2006, "raw": ["008513", "000019", "0", "2008/Feb/19 10:14", "Halstead Boilers", "Halstead", "Finest Gold", "fgx", "", "2001", "2006", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "30", "30", "", "", "80.2", "70.1", "", "49.3", "", "2", "", "", "104", "1", "2", "160", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.5", "81.3", "", "", "", "", "81.3"]} -{"pcdb_id": 8514, "brand_name": "Halstead", "model_name": "Ace", "model_qualifier": "acl", "winter_efficiency_pct": 79.0, "summer_efficiency_pct": 68.9, "comparative_hot_water_efficiency_pct": 48.5, "output_kw_max": 24.0, "final_year_of_manufacture": null, "raw": ["008514", "000019", "0", "2008/Feb/19 11:43", "Halstead Boilers", "Halstead", "Ace", "acl", "", "2001", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "24", "24", "", "", "79.0", "68.9", "", "48.5", "", "2", "", "", "104", "1", "2", "160", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.3", "78.2", "", "", "", "", "79.0"]} -{"pcdb_id": 8515, "brand_name": "Halstead", "model_name": "Wickes", "model_qualifier": "Combi 82", "winter_efficiency_pct": 79.0, "summer_efficiency_pct": 68.9, "comparative_hot_water_efficiency_pct": 48.5, "output_kw_max": 24.0, "final_year_of_manufacture": null, "raw": ["008515", "000019", "0", "2006/Jan/17 12:31", "Halstead Boilers", "Halstead", "Wickes", "Combi 82", "ACLW", "2001", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "24", "24", "", "", "79.0", "68.9", "", "48.5", "", "2", "", "", "104", "1", "2", "160", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.3", "78.2", "", "", "", "", "79.0"]} -{"pcdb_id": 8516, "brand_name": "Halstead", "model_name": "Wickes", "model_qualifier": "Combi 102", "winter_efficiency_pct": 79.5, "summer_efficiency_pct": 69.4, "comparative_hot_water_efficiency_pct": 48.8, "output_kw_max": 30.0, "final_year_of_manufacture": null, "raw": ["008516", "000019", "0", "2006/Jan/17 12:31", "Halstead Boilers", "Halstead", "Wickes", "Combi 102", "ACHW", "2001", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "30", "30", "", "", "79.5", "69.4", "", "48.8", "", "2", "", "", "104", "1", "2", "160", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "83.2", "78.5", "", "", "", "", "79.4"]} -{"pcdb_id": 8517, "brand_name": "Halstead", "model_name": "Ace High", "model_qualifier": "", "winter_efficiency_pct": 79.5, "summer_efficiency_pct": 69.4, "comparative_hot_water_efficiency_pct": 48.8, "output_kw_max": 30.0, "final_year_of_manufacture": null, "raw": ["008517", "000019", "0", "2006/Jan/17 12:31", "Halstead Boilers", "Halstead", "Ace High", "", "ACH", "2001", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "30", "30", "", "", "79.5", "69.4", "", "48.8", "", "2", "", "", "104", "1", "2", "160", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "83.2", "78.5", "", "", "", "", "79.4"]} -{"pcdb_id": 8522, "brand_name": "Geminox", "model_name": "THR 5-25C", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 25.6, "final_year_of_manufacture": 2006, "raw": ["008522", "000212", "0", "2012/Mar/27 10:12", "Geminox SA", "Geminox", "THR 5-25C", "", "5-25C", "1997", "2006", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "25.6", "25.6", "", "", "88.3", "79.3", "", "58.0", "", "2", "", "", "102", "1", "2", "90", "15", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "97.8", "", "", "", "", "95.9"]} -{"pcdb_id": 8523, "brand_name": "Geminox", "model_name": "THR 5-25SEP", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 56.1, "output_kw_max": 25.6, "final_year_of_manufacture": 2006, "raw": ["008523", "000212", "0", "2006/Aug/30 12:40", "Geminox SA", "Geminox", "THR 5-25SEP", "", "5-25SEP", "1998", "2006", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "25.6", "25.6", "", "", "88.3", "79.7", "", "56.1", "", "2", "", "", "104", "1", "2", "90", "15", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "97.8", "", "", "", "", "95.9"]} -{"pcdb_id": 8524, "brand_name": "Geminox", "model_name": "THR 5-25S", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 81.1, "comparative_hot_water_efficiency_pct": 52.4, "output_kw_max": 25.6, "final_year_of_manufacture": 2006, "raw": ["008524", "000212", "0", "2024/Jan/31 10:17", "Geminox SA", "Geminox", "THR 5-25S", "", "5-25S", "1996", "2006", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "25.6", "25.6", "", "", "88.3", "81.1", "", "52.4", "", "2", "", "", "106", "1", "2", "90", "15", "2", "2", "0", "18.5", "0", "30", "2", "65", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "97.8", "", "", "", "", "95.9"]} -{"pcdb_id": 8525, "brand_name": "Geminox", "model_name": "THR 5-25 M75", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 81.2, "comparative_hot_water_efficiency_pct": 49.2, "output_kw_max": 25.6, "final_year_of_manufacture": 2006, "raw": ["008525", "000212", "0", "2024/Jan/31 10:17", "Geminox SA", "Geminox", "THR 5-25 M75", "", "THR M75", "1997", "2006", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "25.6", "25.6", "", "", "88.3", "81.2", "", "49.2", "", "2", "", "", "106", "1", "2", "90", "15", "2", "2", "0", "74", "0", "30", "2", "65", "52", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "97.8", "", "", "", "", "95.9"]} -{"pcdb_id": 8527, "brand_name": "Geminox", "model_name": "THR 10-50", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 50.5, "final_year_of_manufacture": 2006, "raw": ["008527", "000212", "0", "2012/Mar/27 10:12", "Geminox SA", "Geminox", "THR 10-50", "", "THR 50", "1997", "2006", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "50.5", "50.5", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "90", "30", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.7", "97.0", "", "", "", "", "95.3"]} -{"pcdb_id": 8529, "brand_name": "Worcester", "model_name": "9/14 CBi", "model_qualifier": "RSF", "winter_efficiency_pct": 79.4, "summer_efficiency_pct": 69.3, "comparative_hot_water_efficiency_pct": 50.6, "output_kw_max": 14.0, "final_year_of_manufacture": 2005, "raw": ["008529", "000035", "0", "2020/Sep/02 14:14", "Worcester Heat Systems", "Worcester", "9/14 CBi", "RSF", "41-311-50", "2001", "2005", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "9", "14", "", "", "79.4", "69.3", "", "50.6", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.5", "79.5", "", "", "", "", "80.1"]} -{"pcdb_id": 8530, "brand_name": "Worcester", "model_name": "9/14 CBi", "model_qualifier": "RSF", "winter_efficiency_pct": 81.4, "summer_efficiency_pct": 71.3, "comparative_hot_water_efficiency_pct": 52.1, "output_kw_max": 14.0, "final_year_of_manufacture": 2005, "raw": ["008530", "000035", "0", "2020/Sep/02 14:15", "Worcester Heat Systems", "Worcester", "9/14 CBi", "RSF", "41-311-51", "2001", "2005", "2", "2", "1", "1", "0", "", "", "1", "2", "2", "10", "14", "", "", "81.4", "71.3", "", "52.1", "", "2", "0", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "84.5", "81.6", "", "", "", "", "82.1"]} -{"pcdb_id": 8531, "brand_name": "Worcester", "model_name": "14/19 CBi", "model_qualifier": "RSF", "winter_efficiency_pct": 80.3, "summer_efficiency_pct": 70.2, "comparative_hot_water_efficiency_pct": 51.2, "output_kw_max": 19.05, "final_year_of_manufacture": 2005, "raw": ["008531", "000035", "0", "2020/Sep/02 14:15", "Worcester Heat Systems", "Worcester", "14/19 CBi", "RSF", "41-311-52", "2001", "2005", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "14", "19.05", "", "", "80.3", "70.2", "", "51.2", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "83.5", "80.8", "", "", "", "", "81.3"]} -{"pcdb_id": 8532, "brand_name": "Worcester", "model_name": "14/19 CBi", "model_qualifier": "RSF", "winter_efficiency_pct": 82.2, "summer_efficiency_pct": 72.1, "comparative_hot_water_efficiency_pct": 52.6, "output_kw_max": 19.05, "final_year_of_manufacture": 2005, "raw": ["008532", "000035", "0", "2020/Sep/02 14:15", "Worcester Heat Systems", "Worcester", "14/19 CBi", "RSF", "41-311-53", "2001", "2005", "2", "2", "1", "1", "0", "", "", "1", "2", "2", "14", "19.05", "", "", "82.2", "72.1", "", "52.6", "", "2", "0", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.7", "82.8", "", "", "", "", "83.4"]} -{"pcdb_id": 8533, "brand_name": "Worcester", "model_name": "19/24 CBi", "model_qualifier": "RSF", "winter_efficiency_pct": 79.3, "summer_efficiency_pct": 69.2, "comparative_hot_water_efficiency_pct": 50.6, "output_kw_max": 23.45, "final_year_of_manufacture": 2005, "raw": ["008533", "000035", "0", "2020/Sep/02 14:15", "Worcester Heat Systems", "Worcester", "19/24 CBi", "RSF", "41-311-54", "2001", "2005", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "19.05", "23.45", "", "", "79.3", "69.2", "", "50.6", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.1", "79.7", "", "", "", "", "80.2"]} -{"pcdb_id": 8534, "brand_name": "Worcester", "model_name": "19/24 CBi", "model_qualifier": "RSF", "winter_efficiency_pct": 81.3, "summer_efficiency_pct": 71.2, "comparative_hot_water_efficiency_pct": 52.0, "output_kw_max": 23.45, "final_year_of_manufacture": 2005, "raw": ["008534", "000035", "0", "2020/Sep/02 14:15", "Worcester Heat Systems", "Worcester", "19/24 CBi", "RSF", "41-311-55", "2001", "2005", "2", "2", "1", "1", "0", "", "", "1", "2", "2", "19.05", "23.45", "", "", "81.3", "71.2", "", "52.0", "", "2", "0", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "84.4", "81.4", "", "", "", "", "82.0"]} -{"pcdb_id": 8535, "brand_name": "Vaillant", "model_name": "Ecomax", "model_qualifier": "835/2E", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 56.2, "output_kw_max": 27.0, "final_year_of_manufacture": 2010, "raw": ["008535", "000031", "0", "2010/Jan/28 08:35", "Vaillant", "Vaillant", "Ecomax", "835/2E", "VUW 356-C", "2001", "2010", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "27", "27", "", "", "88.5", "79.9", "", "56.2", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.0", "97.2", "", "", "", "", "95.8"]} -{"pcdb_id": 8537, "brand_name": "Radiant", "model_name": "RBA/CS 100 E", "model_qualifier": "", "winter_efficiency_pct": 79.4, "summer_efficiency_pct": 70.3, "comparative_hot_water_efficiency_pct": 26.3, "output_kw_max": 29.8, "final_year_of_manufacture": null, "raw": ["008537", "000088", "0", "2024/Jan/31 10:17", "Radiant Bruciatori SpA", "Radiant", "RBA/CS 100 E", "", "CE 0063AQ6415", "1997", "current", "1", "1", "1", "2", "0", "", "", "1", "2", "2", "29.8", "29.8", "", "", "79.4", "70.3", "", "26.3", "", "2", "", "", "106", "1", "2", "170", "", "1", "2", "0", "107.1", "0", "15", "2", "60", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "80.5", "78.8", "", "", "", "", "79.2"]} -{"pcdb_id": 8538, "brand_name": "Radiant", "model_name": "RBA/CS 24 E", "model_qualifier": "", "winter_efficiency_pct": 79.1, "summer_efficiency_pct": 70.0, "comparative_hot_water_efficiency_pct": 31.8, "output_kw_max": 29.8, "final_year_of_manufacture": null, "raw": ["008538", "000088", "0", "2024/Jan/31 10:17", "Radiant Bruciatori SpA", "Radiant", "RBA/CS 24 E", "", "CE 0063AQ6415", "1997", "current", "1", "1", "1", "2", "0", "", "", "1", "2", "2", "29.8", "29.8", "", "", "79.1", "70.0", "", "31.8", "", "2", "", "", "106", "1", "2", "170", "", "2", "2", "0", "50.7", "0", "15", "2", "60", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "80.5", "78.8", "", "", "", "", "79.2"]} -{"pcdb_id": 8539, "brand_name": "Radiant", "model_name": "RBC 20 E", "model_qualifier": "", "winter_efficiency_pct": 77.6, "summer_efficiency_pct": 67.5, "comparative_hot_water_efficiency_pct": 47.5, "output_kw_max": 26.6, "final_year_of_manufacture": null, "raw": ["008539", "000088", "0", "2006/Jan/17 12:31", "Radiant Bruciatori SpA", "Radiant", "RBC 20 E", "", "CE 0694BL3037", "2000", "current", "1", "2", "1", "2", "0", "", "", "1", "1", "1", "26.6", "26.6", "", "", "77.6", "67.5", "", "47.5", "", "2", "", "", "104", "1", "2", "170", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "80.3", "77.4", "", "", "", "", "77.9"]} -{"pcdb_id": 8540, "brand_name": "Radiant", "model_name": "RBS 20 E", "model_qualifier": "", "winter_efficiency_pct": 78.4, "summer_efficiency_pct": 68.3, "comparative_hot_water_efficiency_pct": 48.0, "output_kw_max": 26.6, "final_year_of_manufacture": 2002, "raw": ["008540", "000088", "0", "2006/Jan/17 12:55", "Radiant Bruciatori SpA", "Radiant", "RBS 20 E", "", "CE 0694BL3037", "2000", "2002", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "26.6", "26.6", "", "", "78.4", "68.3", "", "48.0", "", "2", "", "", "104", "1", "2", "170", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.4", "77.8", "", "", "", "", "78.4"]} -{"pcdb_id": 8541, "brand_name": "Radiant", "model_name": "RMAS 21 E/3S", "model_qualifier": "", "winter_efficiency_pct": 82.2, "summer_efficiency_pct": 73.1, "comparative_hot_water_efficiency_pct": 36.2, "output_kw_max": 26.6, "final_year_of_manufacture": null, "raw": ["008541", "000088", "0", "2024/Jan/31 10:17", "Radiant Bruciatori SpA", "Radiant", "RMAS 21 E/3S", "", "0694BL3003", "2000", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "26.6", "26.6", "", "", "82.2", "73.1", "", "36.2", "", "2", "", "", "106", "1", "2", "170", "", "2", "2", "0", "28.3", "0", "15", "2", "60", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "83.8", "83.0", "", "", "", "", "83.1"]} -{"pcdb_id": 8542, "brand_name": "Radiant", "model_name": "RMAS 21 E NOx", "model_qualifier": "", "winter_efficiency_pct": 81.1, "summer_efficiency_pct": 72.0, "comparative_hot_water_efficiency_pct": 35.6, "output_kw_max": 26.6, "final_year_of_manufacture": null, "raw": ["008542", "000088", "0", "2024/Jan/31 10:17", "Radiant Bruciatori SpA", "Radiant", "RMAS 21 E NOx", "", "CE 0694BL3003", "1998", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "26.6", "26.6", "", "", "81.1", "72.0", "", "35.6", "", "2", "", "", "106", "1", "2", "170", "", "2", "2", "0", "28.3", "0", "15", "2", "60", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.7", "80.9", "", "", "", "", "81.3"]} -{"pcdb_id": 8543, "brand_name": "Radiant", "model_name": "RMAS 24 E", "model_qualifier": "", "winter_efficiency_pct": 78.9, "summer_efficiency_pct": 69.8, "comparative_hot_water_efficiency_pct": 34.6, "output_kw_max": 29.8, "final_year_of_manufacture": null, "raw": ["008543", "000088", "0", "2024/Jan/31 10:17", "Radiant Bruciatori SpA", "Radiant", "RMAS 24 E", "", "CE 0063AQ6415", "1997", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "29.8", "29.8", "", "", "78.9", "69.8", "", "34.6", "", "2", "", "", "106", "1", "2", "170", "", "2", "2", "0", "28.3", "0", "15", "2", "60", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "80.5", "78.8", "", "", "", "", "79.2"]} -{"pcdb_id": 8544, "brand_name": "Radiant", "model_name": "RS 20 E", "model_qualifier": "", "winter_efficiency_pct": 79.5, "summer_efficiency_pct": 68.8, "comparative_hot_water_efficiency_pct": 50.2, "output_kw_max": 26.6, "final_year_of_manufacture": null, "raw": ["008544", "000088", "0", "2012/Mar/27 10:12", "Radiant Bruciatori SpA", "Radiant", "RS 20 E", "", "CE 0063AQ4089", "1997", "current", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "26.6", "26.6", "", "", "79.5", "68.8", "", "50.2", "", "2", "", "", "102", "1", "2", "170", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.4", "78.5", "", "", "", "", "79.2"]} -{"pcdb_id": 8545, "brand_name": "Radiant", "model_name": "RS 21 E/3S", "model_qualifier": "", "winter_efficiency_pct": 81.9, "summer_efficiency_pct": 71.2, "comparative_hot_water_efficiency_pct": 52.0, "output_kw_max": 26.6, "final_year_of_manufacture": null, "raw": ["008545", "000088", "0", "2012/Mar/27 10:12", "Radiant Bruciatori SpA", "Radiant", "RS 21 E/3S", "", "CE 0694BL3003", "2000", "current", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "26.6", "26.6", "", "", "81.9", "71.2", "", "52.0", "", "2", "", "", "102", "1", "2", "170", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "83.8", "83.0", "", "", "", "", "83.1"]} -{"pcdb_id": 8546, "brand_name": "Radiant", "model_name": "RS 21 E NOx", "model_qualifier": "", "winter_efficiency_pct": 80.8, "summer_efficiency_pct": 70.1, "comparative_hot_water_efficiency_pct": 51.2, "output_kw_max": 26.6, "final_year_of_manufacture": null, "raw": ["008546", "000088", "0", "2012/Mar/27 10:12", "Radiant Bruciatori SpA", "Radiant", "RS 21 E NOx", "", "CE 0694BL3003", "1998", "current", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "26.6", "26.6", "", "", "80.8", "70.1", "", "51.2", "", "2", "", "", "102", "1", "2", "170", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.7", "80.9", "", "", "", "", "81.3"]} -{"pcdb_id": 8547, "brand_name": "Radiant", "model_name": "RS 24 E", "model_qualifier": "", "winter_efficiency_pct": 78.7, "summer_efficiency_pct": 68.0, "comparative_hot_water_efficiency_pct": 49.7, "output_kw_max": 29.8, "final_year_of_manufacture": 2002, "raw": ["008547", "000088", "0", "2012/Mar/27 10:12", "Radiant Bruciatori SpA", "Radiant", "RS 24 E", "", "CE 0063AQ6415", "1997", "2002", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "29.8", "29.8", "", "", "78.7", "68.0", "", "49.7", "", "2", "", "", "102", "1", "2", "170", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "80.5", "78.8", "", "", "", "", "79.2"]} -{"pcdb_id": 8548, "brand_name": "Radiant", "model_name": "RSF 20 E", "model_qualifier": "", "winter_efficiency_pct": 79.3, "summer_efficiency_pct": 69.2, "comparative_hot_water_efficiency_pct": 48.6, "output_kw_max": 26.6, "final_year_of_manufacture": null, "raw": ["008548", "000088", "0", "2006/Jan/17 12:31", "Radiant Bruciatori SpA", "Radiant", "RSF 20 E", "", "CE 0063AQ4089", "1997", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "26.6", "26.6", "", "", "79.3", "69.2", "", "48.6", "", "2", "", "", "104", "1", "2", "170", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.4", "78.5", "", "", "", "", "79.2"]} -{"pcdb_id": 8549, "brand_name": "Radiant", "model_name": "RSF 21 E/3S", "model_qualifier": "", "winter_efficiency_pct": 81.7, "summer_efficiency_pct": 71.6, "comparative_hot_water_efficiency_pct": 50.4, "output_kw_max": 26.6, "final_year_of_manufacture": null, "raw": ["008549", "000088", "0", "2006/Jan/17 12:31", "Radiant Bruciatori SpA", "Radiant", "RSF 21 E/3S", "", "CE 0694BL3003", "2000", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "26.6", "26.6", "", "", "81.7", "71.6", "", "50.4", "", "2", "", "", "104", "1", "2", "170", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "83.8", "83.0", "", "", "", "", "83.1"]} -{"pcdb_id": 8550, "brand_name": "Radiant", "model_name": "RSF 21 E NOx", "model_qualifier": "", "winter_efficiency_pct": 80.6, "summer_efficiency_pct": 70.5, "comparative_hot_water_efficiency_pct": 49.6, "output_kw_max": 26.6, "final_year_of_manufacture": null, "raw": ["008550", "000088", "0", "2006/Jan/17 12:31", "Radiant Bruciatori SpA", "Radiant", "RSF 21 E NOx", "", "CE 0694BL3003", "1998", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "26.6", "26.6", "", "", "80.6", "70.5", "", "49.6", "", "2", "", "", "104", "1", "2", "170", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.7", "80.9", "", "", "", "", "81.3"]} -{"pcdb_id": 8551, "brand_name": "Radiant", "model_name": "RSF 24 E", "model_qualifier": "", "winter_efficiency_pct": 78.5, "summer_efficiency_pct": 68.4, "comparative_hot_water_efficiency_pct": 48.1, "output_kw_max": 29.8, "final_year_of_manufacture": 2002, "raw": ["008551", "000088", "0", "2006/Jan/17 12:55", "Radiant Bruciatori SpA", "Radiant", "RSF 24 E", "", "CE 0063AQ6415", "1997", "2002", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "29.8", "29.8", "", "", "78.5", "68.4", "", "48.1", "", "2", "", "", "104", "1", "2", "170", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "80.5", "78.8", "", "", "", "", "79.2"]} -{"pcdb_id": 8552, "brand_name": "Gledhill", "model_name": "Gulfstream 2000", "model_qualifier": "GS2000/120/E-OV", "winter_efficiency_pct": 84.5, "summer_efficiency_pct": 85.3, "comparative_hot_water_efficiency_pct": 71.9, "output_kw_max": 19.8, "final_year_of_manufacture": 2005, "raw": ["008552", "000072", "0", "2006/Mar/29 14:30", "Gledhill", "Gledhill", "Gulfstream 2000", "GS2000/120/E-OV", "12 OV", "2001", "2005", "1", "1", "1", "3", "0", "", "", "2", "2", "2", "19.8", "19.8", "", "", "84.5", "85.3", "", "71.9", "", "2", "", "", "107", "1", "2", "", "", "3", "2", "0", "80", "0", "60", "2", "80", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "84.5", "90.7", "", "", "", "", "89.5"]} -{"pcdb_id": 8553, "brand_name": "Gledhill", "model_name": "Gulfstream 2000", "model_qualifier": "GS2000/120/E", "winter_efficiency_pct": 84.5, "summer_efficiency_pct": 85.3, "comparative_hot_water_efficiency_pct": 71.9, "output_kw_max": 19.8, "final_year_of_manufacture": 2005, "raw": ["008553", "000072", "0", "2007/Apr/24 10:44", "Gledhill", "Gledhill", "Gulfstream 2000", "GS2000/120/E", "12 SP", "2001", "2005", "1", "1", "1", "3", "0", "", "", "2", "2", "2", "19.8", "19.8", "", "", "84.5", "85.3", "", "71.9", "", "2", "", "", "107", "1", "2", "", "", "3", "2", "0", "80", "0", "60", "2", "80", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "84.5", "90.7", "", "", "", "", "89.5"]} -{"pcdb_id": 8554, "brand_name": "Gledhill", "model_name": "Gulfstream 2000", "model_qualifier": "GS2000/130/E-OV", "winter_efficiency_pct": 85.0, "summer_efficiency_pct": 85.8, "comparative_hot_water_efficiency_pct": 72.3, "output_kw_max": 29.3, "final_year_of_manufacture": 2005, "raw": ["008554", "000072", "0", "2006/Mar/29 14:29", "Gledhill", "Gledhill", "Gulfstream 2000", "GS2000/130/E-OV", "18 OV", "2001", "2005", "1", "1", "1", "3", "0", "", "", "2", "2", "2", "29.3", "29.3", "", "", "85.0", "85.8", "", "72.3", "", "2", "", "", "107", "1", "2", "", "", "3", "2", "0", "80", "0", "60", "2", "80", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "85.3", "91.0", "", "", "", "", "89.9"]} -{"pcdb_id": 8555, "brand_name": "Gledhill", "model_name": "Gulfstream 2000", "model_qualifier": "GS2000/130/E", "winter_efficiency_pct": 85.0, "summer_efficiency_pct": 85.8, "comparative_hot_water_efficiency_pct": 72.3, "output_kw_max": 29.3, "final_year_of_manufacture": 2005, "raw": ["008555", "000072", "0", "2006/Mar/29 14:30", "Gledhill", "Gledhill", "Gulfstream 2000", "GS2000/130/E", "18 SP", "2001", "2005", "1", "1", "1", "3", "0", "", "", "2", "2", "2", "29.3", "29.3", "", "", "85.0", "85.8", "", "72.3", "", "2", "", "", "107", "1", "2", "", "", "3", "2", "0", "80", "0", "60", "2", "80", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "85.3", "91.0", "", "", "", "", "89.9"]} -{"pcdb_id": 8556, "brand_name": "Baxi Potterton", "model_name": "Baxi Bermuda Inset 2", "model_qualifier": "50/4E", "winter_efficiency_pct": 78.4, "summer_efficiency_pct": 68.3, "comparative_hot_water_efficiency_pct": 49.9, "output_kw_max": 14.65, "final_year_of_manufacture": 2003, "raw": ["008556", "000005", "0", "2012/Mar/27 10:12", "Baxi Potterton", "Baxi Potterton", "Baxi Bermuda Inset 2", "50/4E", "44-075-03", "2000", "2003", "1", "4", "1", "1", "0", "", "", "1", "1", "1", "11.72", "14.65", "", "", "78.4", "68.3", "", "49.9", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.6", "78.4", "", "", "", "", "79.0"]} -{"pcdb_id": 8557, "brand_name": "Potterton", "model_name": "Profile", "model_qualifier": "80eL", "winter_efficiency_pct": 79.3, "summer_efficiency_pct": 69.2, "comparative_hot_water_efficiency_pct": 50.5, "output_kw_max": 23.45, "final_year_of_manufacture": 2006, "raw": ["008557", "000005", "0", "2012/Mar/27 10:12", "Baxi Potterton", "Potterton", "Profile", "80eL", "41-590-53", "2001", "2006", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "23.45", "23.45", "", "", "79.3", "69.2", "", "50.5", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.5", "80.3", "", "", "", "", "80.5"]} -{"pcdb_id": 8558, "brand_name": "Potterton", "model_name": "Profile", "model_qualifier": "60eL", "winter_efficiency_pct": 79.1, "summer_efficiency_pct": 69.0, "comparative_hot_water_efficiency_pct": 50.4, "output_kw_max": 17.58, "final_year_of_manufacture": 2005, "raw": ["008558", "000005", "0", "2012/Mar/27 10:12", "Baxi Potterton", "Potterton", "Profile", "60eL", "41-590-52", "2001", "2005", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "17.58", "17.58", "", "", "79.1", "69.0", "", "50.4", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.0", "80.5", "", "", "", "", "80.6"]} -{"pcdb_id": 8559, "brand_name": "Potterton", "model_name": "Profile", "model_qualifier": "50eL", "winter_efficiency_pct": 79.2, "summer_efficiency_pct": 69.1, "comparative_hot_water_efficiency_pct": 50.5, "output_kw_max": 14.65, "final_year_of_manufacture": 2006, "raw": ["008559", "000005", "0", "2012/Mar/27 10:12", "Baxi Potterton", "Potterton", "Profile", "50eL", "41-590-51", "2001", "2006", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "14.65", "14.65", "", "", "79.2", "69.1", "", "50.5", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.1", "80.5", "", "", "", "", "80.6"]} -{"pcdb_id": 8560, "brand_name": "Potterton", "model_name": "Profile", "model_qualifier": "40eL", "winter_efficiency_pct": 78.9, "summer_efficiency_pct": 68.8, "comparative_hot_water_efficiency_pct": 50.3, "output_kw_max": 11.72, "final_year_of_manufacture": 2006, "raw": ["008560", "000005", "0", "2012/Mar/27 10:12", "Baxi Potterton", "Potterton", "Profile", "40eL", "41-590-50", "2001", "2006", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "11.72", "11.72", "", "", "78.9", "68.8", "", "50.3", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.2", "79.9", "", "", "", "", "80.2"]} -{"pcdb_id": 8561, "brand_name": "Potterton", "model_name": "Kingfisher MF", "model_qualifier": "RSL100", "winter_efficiency_pct": 78.9, "summer_efficiency_pct": 68.8, "comparative_hot_water_efficiency_pct": 50.3, "output_kw_max": 29.31, "final_year_of_manufacture": 2006, "raw": ["008561", "000005", "0", "2012/Mar/27 10:12", "Baxi Potterton", "Potterton", "Kingfisher MF", "RSL100", "41-590-41", "2001", "2006", "1", "1", "1", "1", "0", "", "", "1", "2", "2", "29.31", "29.31", "", "", "78.9", "68.8", "", "50.3", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.0", "80.0", "", "", "", "", "80.2"]} -{"pcdb_id": 8562, "brand_name": "Potterton", "model_name": "Kingfisher MF", "model_qualifier": "RSL90", "winter_efficiency_pct": 79.0, "summer_efficiency_pct": 68.9, "comparative_hot_water_efficiency_pct": 50.3, "output_kw_max": 26.38, "final_year_of_manufacture": 2005, "raw": ["008562", "000005", "0", "2012/Mar/27 10:12", "Baxi Potterton", "Potterton", "Kingfisher MF", "RSL90", "41-590-40", "2001", "2005", "1", "1", "1", "1", "0", "", "", "1", "2", "2", "26.38", "26.38", "", "", "79.0", "68.9", "", "50.3", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.1", "80.1", "", "", "", "", "80.3"]} -{"pcdb_id": 8563, "brand_name": "Potterton", "model_name": "Kingfisher MF", "model_qualifier": "RSL80", "winter_efficiency_pct": 79.1, "summer_efficiency_pct": 69.0, "comparative_hot_water_efficiency_pct": 50.4, "output_kw_max": 23.45, "final_year_of_manufacture": 2007, "raw": ["008563", "000005", "0", "2012/Mar/27 10:12", "Baxi Potterton", "Potterton", "Kingfisher MF", "RSL80", "41-590-39", "2001", "2007", "1", "1", "1", "1", "0", "", "", "1", "2", "2", "23.45", "23.45", "", "", "79.1", "69.0", "", "50.4", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.2", "80.2", "", "", "", "", "80.4"]} -{"pcdb_id": 8564, "brand_name": "Potterton", "model_name": "Kingfisher MF", "model_qualifier": "RSL70", "winter_efficiency_pct": 79.0, "summer_efficiency_pct": 68.9, "comparative_hot_water_efficiency_pct": 50.4, "output_kw_max": 20.52, "final_year_of_manufacture": 2006, "raw": ["008564", "000005", "0", "2012/Mar/27 10:12", "Baxi Potterton", "Potterton", "Kingfisher MF", "RSL70", "41-590-38", "2001", "2006", "1", "1", "1", "1", "0", "", "", "1", "2", "2", "20.52", "20.52", "", "", "79.0", "68.9", "", "50.4", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.1", "80.2", "", "", "", "", "80.4"]} -{"pcdb_id": 8565, "brand_name": "Potterton", "model_name": "Kingfisher MF", "model_qualifier": "RSL60", "winter_efficiency_pct": 79.4, "summer_efficiency_pct": 69.3, "comparative_hot_water_efficiency_pct": 50.6, "output_kw_max": 17.58, "final_year_of_manufacture": 2006, "raw": ["008565", "000005", "0", "2012/Mar/27 10:12", "Baxi Potterton", "Potterton", "Kingfisher MF", "RSL60", "41-590-37", "2001", "2006", "1", "1", "1", "1", "0", "", "", "1", "2", "2", "17.58", "17.58", "", "", "79.4", "69.3", "", "50.6", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.5", "80.5", "", "", "", "", "80.7"]} -{"pcdb_id": 8566, "brand_name": "Potterton", "model_name": "Kingfisher MF", "model_qualifier": "RSL50", "winter_efficiency_pct": 79.4, "summer_efficiency_pct": 69.3, "comparative_hot_water_efficiency_pct": 50.6, "output_kw_max": 14.65, "final_year_of_manufacture": 2007, "raw": ["008566", "000005", "0", "2012/Mar/27 10:12", "Baxi Potterton", "Potterton", "Kingfisher MF", "RSL50", "", "2001", "2007", "1", "1", "1", "1", "0", "", "", "1", "2", "2", "14.65", "14.65", "", "", "79.4", "69.3", "", "50.6", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.5", "80.4", "", "", "", "", "80.6"]} -{"pcdb_id": 8567, "brand_name": "Potterton", "model_name": "Kingfisher MF", "model_qualifier": "CFL100", "winter_efficiency_pct": 78.9, "summer_efficiency_pct": 68.8, "comparative_hot_water_efficiency_pct": 50.2, "output_kw_max": 29.31, "final_year_of_manufacture": 2005, "raw": ["008567", "000005", "0", "2012/Mar/27 10:12", "Baxi Potterton", "Potterton", "Kingfisher MF", "CFL100", "41-590-34", "2001", "2005", "1", "1", "1", "1", "0", "", "", "1", "1", "2", "29.31", "29.31", "", "", "78.9", "68.8", "", "50.2", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.2", "79.7", "", "", "", "", "80.0"]} -{"pcdb_id": 8568, "brand_name": "Potterton", "model_name": "Kingfisher MF", "model_qualifier": "CFL90", "winter_efficiency_pct": 78.9, "summer_efficiency_pct": 68.8, "comparative_hot_water_efficiency_pct": 50.2, "output_kw_max": 26.38, "final_year_of_manufacture": 2005, "raw": ["008568", "000005", "0", "2012/Mar/27 10:12", "Baxi Potterton", "Potterton", "Kingfisher MF", "CFL90", "41-590-32", "2001", "2005", "1", "1", "1", "1", "0", "", "", "1", "1", "2", "26.38", "26.38", "", "", "78.9", "68.8", "", "50.2", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.1", "79.8", "", "", "", "", "80.1"]} -{"pcdb_id": 8569, "brand_name": "Potterton", "model_name": "Kingfisher MF", "model_qualifier": "CFL80", "winter_efficiency_pct": 79.2, "summer_efficiency_pct": 69.1, "comparative_hot_water_efficiency_pct": 50.5, "output_kw_max": 23.45, "final_year_of_manufacture": 2007, "raw": ["008569", "000005", "0", "2012/Mar/27 10:12", "Baxi Potterton", "Potterton", "Kingfisher MF", "CFL80", "41-590-31", "2001", "2007", "1", "1", "1", "1", "0", "", "", "1", "1", "2", "23.45", "23.45", "", "", "79.2", "69.1", "", "50.5", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.3", "80.3", "", "", "", "", "80.5"]} -{"pcdb_id": 8570, "brand_name": "Potterton", "model_name": "Kingfisher MF", "model_qualifier": "CFL70", "winter_efficiency_pct": 78.9, "summer_efficiency_pct": 68.8, "comparative_hot_water_efficiency_pct": 50.3, "output_kw_max": 20.52, "final_year_of_manufacture": 2006, "raw": ["008570", "000005", "0", "2012/Mar/27 10:12", "Baxi Potterton", "Potterton", "Kingfisher MF", "CFL70", "41-590-30", "2001", "2006", "1", "1", "1", "1", "0", "", "", "1", "1", "2", "20.52", "20.52", "", "", "78.9", "68.8", "", "50.3", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.1", "79.9", "", "", "", "", "80.1"]} -{"pcdb_id": 8571, "brand_name": "Potterton", "model_name": "Kingfisher MF", "model_qualifier": "CFL60", "winter_efficiency_pct": 78.9, "summer_efficiency_pct": 68.8, "comparative_hot_water_efficiency_pct": 50.3, "output_kw_max": 17.58, "final_year_of_manufacture": 2006, "raw": ["008571", "000005", "0", "2012/Mar/27 10:12", "Baxi Potterton", "Potterton", "Kingfisher MF", "CFL60", "41-590-29", "2001", "2006", "1", "1", "1", "1", "0", "", "", "1", "1", "2", "17.58", "17.58", "", "", "78.9", "68.8", "", "50.3", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.0", "80.0", "", "", "", "", "80.2"]} -{"pcdb_id": 8572, "brand_name": "Potterton", "model_name": "Kingfisher MF", "model_qualifier": "CFL50", "winter_efficiency_pct": 79.4, "summer_efficiency_pct": 69.3, "comparative_hot_water_efficiency_pct": 50.6, "output_kw_max": 14.65, "final_year_of_manufacture": 2007, "raw": ["008572", "000005", "0", "2012/Mar/27 10:12", "Baxi Potterton", "Potterton", "Kingfisher MF", "CFL50", "41-590-28", "2001", "2007", "1", "1", "1", "1", "0", "", "", "1", "1", "2", "14.65", "14.65", "", "", "79.4", "69.3", "", "50.6", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.6", "80.3", "", "", "", "", "80.5"]} -{"pcdb_id": 8573, "brand_name": "Potterton", "model_name": "Suprima", "model_qualifier": "30L", "winter_efficiency_pct": 78.9, "summer_efficiency_pct": 68.8, "comparative_hot_water_efficiency_pct": 50.3, "output_kw_max": 8.8, "final_year_of_manufacture": 2005, "raw": ["008573", "000005", "0", "2012/Mar/27 10:12", "Baxi Potterton", "Potterton", "Suprima", "30L", "41-590-42", "2001", "2005", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "8.8", "8.8", "", "", "78.9", "68.8", "", "50.3", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.3", "79.7", "", "", "", "", "80.0"]} -{"pcdb_id": 8574, "brand_name": "Potterton", "model_name": "Suprima", "model_qualifier": "40L", "winter_efficiency_pct": 79.4, "summer_efficiency_pct": 69.3, "comparative_hot_water_efficiency_pct": 50.6, "output_kw_max": 11.7, "final_year_of_manufacture": 2006, "raw": ["008574", "000005", "0", "2012/Mar/27 10:12", "Baxi Potterton", "Potterton", "Suprima", "40L", "41-590-43", "2001", "2006", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "11.7", "11.7", "", "", "79.4", "69.3", "", "50.6", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.6", "80.4", "", "", "", "", "80.6"]} -{"pcdb_id": 8575, "brand_name": "Potterton", "model_name": "Suprima", "model_qualifier": "50L", "winter_efficiency_pct": 79.0, "summer_efficiency_pct": 68.9, "comparative_hot_water_efficiency_pct": 50.3, "output_kw_max": 14.7, "final_year_of_manufacture": 2010, "raw": ["008575", "000005", "0", "2012/Mar/27 10:12", "Baxi Potterton", "Potterton", "Suprima", "50L", "41-590-44", "2001", "2010", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "14.7", "14.7", "", "", "79.0", "68.9", "", "50.3", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.1", "80.1", "", "", "", "", "80.3"]} -{"pcdb_id": 8576, "brand_name": "Potterton", "model_name": "Suprima", "model_qualifier": "60L", "winter_efficiency_pct": 79.0, "summer_efficiency_pct": 68.9, "comparative_hot_water_efficiency_pct": 50.3, "output_kw_max": 17.6, "final_year_of_manufacture": 2010, "raw": ["008576", "000005", "0", "2012/Mar/27 10:12", "Baxi Potterton", "Potterton", "Suprima", "60L", "41-590-45", "2001", "2010", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "17.6", "17.6", "", "", "79.0", "68.9", "", "50.3", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.1", "80.1", "", "", "", "", "80.3"]} -{"pcdb_id": 8577, "brand_name": "Potterton", "model_name": "Suprima", "model_qualifier": "70L", "winter_efficiency_pct": 79.5, "summer_efficiency_pct": 69.4, "comparative_hot_water_efficiency_pct": 50.7, "output_kw_max": 20.5, "final_year_of_manufacture": 2006, "raw": ["008577", "000005", "0", "2012/Mar/27 10:12", "Baxi Potterton", "Potterton", "Suprima", "70L", "41-590-46", "2001", "2006", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "20.5", "20.5", "", "", "79.5", "69.4", "", "50.7", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.9", "80.4", "", "", "", "", "80.7"]} -{"pcdb_id": 8578, "brand_name": "Potterton", "model_name": "Suprima", "model_qualifier": "80L", "winter_efficiency_pct": 79.7, "summer_efficiency_pct": 69.6, "comparative_hot_water_efficiency_pct": 50.9, "output_kw_max": 23.4, "final_year_of_manufacture": 2010, "raw": ["008578", "000005", "0", "2012/Mar/27 10:12", "Baxi Potterton", "Potterton", "Suprima", "80L", "41-590-47", "2001", "2010", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "23.4", "23.4", "", "", "79.7", "69.6", "", "50.9", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.9", "80.7", "", "", "", "", "81.0"]} -{"pcdb_id": 8579, "brand_name": "Potterton", "model_name": "Suprima", "model_qualifier": "100L", "winter_efficiency_pct": 78.9, "summer_efficiency_pct": 68.8, "comparative_hot_water_efficiency_pct": 50.3, "output_kw_max": 28.72, "final_year_of_manufacture": 2006, "raw": ["008579", "000005", "0", "2012/Mar/27 10:12", "Baxi Potterton", "Potterton", "Suprima", "100L", "41-590-48", "2001", "2006", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "28.72", "28.72", "", "", "78.9", "68.8", "", "50.3", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.1", "79.9", "", "", "", "", "80.1"]} -{"pcdb_id": 8580, "brand_name": "Potterton", "model_name": "Suprima", "model_qualifier": "120L", "winter_efficiency_pct": 79.6, "summer_efficiency_pct": 69.5, "comparative_hot_water_efficiency_pct": 50.8, "output_kw_max": 35.17, "final_year_of_manufacture": 2006, "raw": ["008580", "000005", "0", "2012/Mar/27 10:12", "Baxi Potterton", "Potterton", "Suprima", "120L", "41-590-49", "2001", "2006", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "35.17", "35.17", "", "", "79.6", "69.5", "", "50.8", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.5", "80.9", "", "", "", "", "81.0"]} -{"pcdb_id": 8581, "brand_name": "Aquaflame", "model_name": "Eco-Avance 30", "model_qualifier": "", "winter_efficiency_pct": 87.0, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 30.4, "final_year_of_manufacture": null, "raw": ["008581", "000039", "0", "2012/Mar/27 10:12", "Aquaflame", "Aquaflame", "Eco-Avance 30", "", "", "2001", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "30.4", "30.4", "", "", "87.0", "79.2", "", "57.8", "", "2", "", "", "201", "1", "1", "100", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.4", "92.3", "", "", "", "", "91.9"]} -{"pcdb_id": 8584, "brand_name": "Aquaflame", "model_name": "Eco-Avance 25", "model_qualifier": "", "winter_efficiency_pct": 87.3, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 24.9, "final_year_of_manufacture": null, "raw": ["008584", "000039", "0", "2012/Mar/27 10:12", "Aquaflame", "Aquaflame", "Eco-Avance 25", "", "", "2001", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "24.9", "24.9", "", "", "87.3", "79.5", "", "58.1", "", "2", "", "", "201", "1", "1", "100", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.4", "93.1", "", "", "", "", "92.6"]} -{"pcdb_id": 8585, "brand_name": "Aquaflame", "model_name": "Eco-Avance 28", "model_qualifier": "", "winter_efficiency_pct": 87.4, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 27.6, "final_year_of_manufacture": null, "raw": ["008585", "000039", "0", "2012/Mar/27 10:12", "Aquaflame", "Aquaflame", "Eco-Avance 28", "", "", "2001", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "27.6", "27.6", "", "", "87.4", "79.6", "", "58.2", "", "2", "", "", "201", "1", "1", "100", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.5", "93.4", "", "", "", "", "92.9"]} -{"pcdb_id": 8587, "brand_name": "Worcester", "model_name": "24i - L", "model_qualifier": "RSF", "winter_efficiency_pct": 79.2, "summer_efficiency_pct": 69.1, "comparative_hot_water_efficiency_pct": 48.6, "output_kw_max": 23.4, "final_year_of_manufacture": 2003, "raw": ["008587", "000035", "0", "2020/Sep/02 14:15", "Worcester Heat Systems", "Worcester", "24i - L", "RSF", "47 311 37", "1998", "2003", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "23.4", "23.4", "", "", "79.2", "69.1", "", "48.6", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.4", "78.3", "", "", "", "", "79.1"]} -{"pcdb_id": 8588, "brand_name": "Worcester", "model_name": "25 Si - L", "model_qualifier": "RSF", "winter_efficiency_pct": 78.9, "summer_efficiency_pct": 68.8, "comparative_hot_water_efficiency_pct": 48.4, "output_kw_max": 25.0, "final_year_of_manufacture": 2001, "raw": ["008588", "000035", "0", "2001/Nov/22 08:37", "Worcester Heat Systems", "Worcester", "25 Si - L", "RSF", "47 311 49", "1999", "2001", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "25", "25", "", "", "78.9", "68.8", "", "48.4", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "83.2", "77.4", "", "", "", "", "78.5"]} -{"pcdb_id": 8589, "brand_name": "Worcester", "model_name": "25 Si - L", "model_qualifier": "RSF", "winter_efficiency_pct": 82.0, "summer_efficiency_pct": 71.9, "comparative_hot_water_efficiency_pct": 50.5, "output_kw_max": 25.0, "final_year_of_manufacture": 2001, "raw": ["008589", "000035", "0", "2002/Feb/26 12:02", "Worcester Heat Systems", "Worcester", "25 Si - L", "RSF", "47 311 50", "1999", "2001", "2", "2", "1", "2", "0", "", "", "1", "2", "2", "25", "25", "", "", "82.0", "71.9", "", "50.5", "", "2", "0", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "86.0", "81.6", "", "", "", "", "82.4"]} -{"pcdb_id": 8591, "brand_name": "Atmos", "model_name": "Atmos Compact System Boiler", "model_qualifier": "N30B", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 24.5, "final_year_of_manufacture": 2006, "raw": ["008591", "000141", "0", "2012/Mar/27 10:12", "Coopra BV", "Atmos", "Atmos Compact System Boiler", "N30B", "", "1997", "2006", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24.5", "24.5", "", "", "88.7", "79.7", "", "58.2", "", "2", "", "", "102", "1", "2", "65", "10", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.0", "98.0", "", "", "", "", "96.3"]} -{"pcdb_id": 8592, "brand_name": "Atmos", "model_name": "Atmos Compact Combi", "model_qualifier": "N30K", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 56.3, "output_kw_max": 24.5, "final_year_of_manufacture": 2006, "raw": ["008592", "000141", "0", "2011/Aug/18 10:41", "Coopra BV", "Atmos", "Atmos Compact Combi", "N30K", "", "1997", "2006", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.5", "24.5", "", "", "88.7", "80.1", "", "56.3", "", "2", "", "", "104", "1", "2", "65", "10", "0", "", "", "3.5", "0", "20", "1", "60", "", "0", "", "", "", "", "", "", "", "", "", "1", "0", "", "0005", "", "", "", "", "", "", "", "", "89.0", "98.0", "", "", "", "", "96.3"]} -{"pcdb_id": 8593, "brand_name": "Atmos", "model_name": "Atmos Compact Boiler", "model_qualifier": "N30C", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 24.5, "final_year_of_manufacture": 2006, "raw": ["008593", "000141", "0", "2012/Mar/27 10:12", "Coopra BV", "Atmos", "Atmos Compact Boiler", "N30C", "", "1997", "2006", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24.5", "24.5", "", "", "88.7", "79.7", "", "58.2", "", "2", "", "", "102", "1", "2", "65", "10", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.0", "98.0", "", "", "", "", "96.3"]} -{"pcdb_id": 8594, "brand_name": "Worcester", "model_name": "28 CDi", "model_qualifier": "RSF", "winter_efficiency_pct": 80.8, "summer_efficiency_pct": 70.7, "comparative_hot_water_efficiency_pct": 49.7, "output_kw_max": 24.0, "final_year_of_manufacture": 2002, "raw": ["008594", "000035", "0", "2006/Jan/17 12:55", "Worcester Heat Systems", "Worcester", "28 CDi", "RSF", "47 311 35", "1997", "2002", "2", "2", "1", "2", "0", "", "", "1", "2", "2", "24.0", "24.0", "", "", "80.8", "70.7", "", "49.7", "", "2", "0", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "84.3", "79.7", "", "", "", "", "80.5"]} -{"pcdb_id": 8595, "brand_name": "Boulter", "model_name": "Pathfinder GA", "model_qualifier": "36 kW", "winter_efficiency_pct": 80.2, "summer_efficiency_pct": 70.1, "comparative_hot_water_efficiency_pct": 51.2, "output_kw_max": 36.0, "final_year_of_manufacture": null, "raw": ["008595", "000041", "0", "2012/Mar/27 10:12", "Boulter Boilers", "Boulter", "Pathfinder GA", "36 kW", "", "2001", "obsolete", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "36", "36", "", "", "80.2", "70.1", "", "51.2", "", "2", "", "", "101", "1", "1", "10", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.8", "81.8", "", "", "", "", "81.8"]} -{"pcdb_id": 8596, "brand_name": "Boulter", "model_name": "Pathfinder GA", "model_qualifier": "48 kW", "winter_efficiency_pct": 80.5, "summer_efficiency_pct": 70.4, "comparative_hot_water_efficiency_pct": 51.4, "output_kw_max": 48.0, "final_year_of_manufacture": null, "raw": ["008596", "000041", "0", "2012/Mar/27 10:12", "Boulter Boilers", "Boulter", "Pathfinder GA", "48 kW", "", "2001", "obsolete", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "48", "48", "", "", "80.5", "70.4", "", "51.4", "", "2", "", "", "101", "1", "1", "10", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.7", "81.5", "", "", "", "", "81.7"]} -{"pcdb_id": 8597, "brand_name": "Sime", "model_name": "Format 100 C", "model_qualifier": "", "winter_efficiency_pct": 80.1, "summer_efficiency_pct": 70.0, "comparative_hot_water_efficiency_pct": 49.2, "output_kw_max": 28.8, "final_year_of_manufacture": 2018, "raw": ["008597", "000213", "0", "2018/Feb/26 16:57", "Fonderie Sime S.p.A.", "Sime", "Format 100 C", "", "", "2001", "2018", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "28.8", "28.8", "", "", "80.1", "70.0", "", "49.2", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.0", "80.5", "", "", "", "", "80.8"]} -{"pcdb_id": 8598, "brand_name": "Sime", "model_name": "Format 80 C", "model_qualifier": "", "winter_efficiency_pct": 79.9, "summer_efficiency_pct": 69.8, "comparative_hot_water_efficiency_pct": 49.1, "output_kw_max": 23.4, "final_year_of_manufacture": 2018, "raw": ["008598", "000213", "0", "2018/Feb/26 17:05", "Fonderie Sime S.p.A.", "Sime", "Format 80 C", "", "", "2001", "2018", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "23.4", "23.4", "", "", "79.9", "69.8", "", "49.1", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.7", "80.5", "", "", "", "", "80.8"]} -{"pcdb_id": 8599, "brand_name": "Sime", "model_name": "Planet Super 4 W.M", "model_qualifier": "", "winter_efficiency_pct": 81.9, "summer_efficiency_pct": 72.8, "comparative_hot_water_efficiency_pct": 39.1, "output_kw_max": 29.5, "final_year_of_manufacture": 2018, "raw": ["008599", "000213", "0", "2024/Jan/31 10:17", "Fonderie Sime S.p.A.", "Sime", "Planet Super 4 W.M", "", "", "2001", "2018", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "29.50", "29.50", "", "", "81.9", "72.8", "", "39.1", "", "2", "", "", "106", "1", "2", "", "", "2", "1", "0", "65", "0", "18", "2", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "84.2", "82.8", "", "", "", "", "83.1"]} -{"pcdb_id": 8600, "brand_name": "Sime", "model_name": "Superior 90 MK.II", "model_qualifier": "", "winter_efficiency_pct": 77.7, "summer_efficiency_pct": 67.6, "comparative_hot_water_efficiency_pct": 49.4, "output_kw_max": 25.5, "final_year_of_manufacture": 2018, "raw": ["008600", "000213", "0", "2018/Mar/05 15:14", "Fonderie Sime S.p.A.", "Sime", "Superior 90 MK.II", "", "", "2000", "2018", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "22", "25.5", "", "", "77.7", "67.6", "", "49.4", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "80.1", "78.5", "", "", "", "", "78.8"]} -{"pcdb_id": 8601, "brand_name": "Sime", "model_name": "Superior 75 MK.II", "model_qualifier": "", "winter_efficiency_pct": 77.4, "summer_efficiency_pct": 67.3, "comparative_hot_water_efficiency_pct": 49.2, "output_kw_max": 22.0, "final_year_of_manufacture": 2018, "raw": ["008601", "000213", "0", "2018/Mar/05 15:13", "Fonderie Sime S.p.A.", "Sime", "Superior 75 MK.II", "", "", "2000", "2018", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "17.6", "22.0", "", "", "77.4", "67.3", "", "49.2", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.6", "78.4", "", "", "", "", "78.6"]} -{"pcdb_id": 8602, "brand_name": "Sime", "model_name": "Superior 60 MK.II", "model_qualifier": "", "winter_efficiency_pct": 76.6, "summer_efficiency_pct": 66.5, "comparative_hot_water_efficiency_pct": 48.6, "output_kw_max": 17.7, "final_year_of_manufacture": 2018, "raw": ["008602", "000213", "0", "2018/Mar/05 15:12", "Fonderie Sime S.p.A.", "Sime", "Superior 60 MK.II", "", "", "2000", "2018", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "14.4", "17.7", "", "", "76.6", "66.5", "", "48.6", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.0", "77.4", "", "", "", "", "77.7"]} -{"pcdb_id": 8603, "brand_name": "Sime", "model_name": "Superior 50 MK.II", "model_qualifier": "", "winter_efficiency_pct": 77.2, "summer_efficiency_pct": 67.1, "comparative_hot_water_efficiency_pct": 49.0, "output_kw_max": 14.6, "final_year_of_manufacture": 2018, "raw": ["008603", "000213", "0", "2018/Mar/05 15:11", "Fonderie Sime S.p.A.", "Sime", "Superior 50 MK.II", "", "", "2000", "2018", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "11.5", "14.6", "", "", "77.2", "67.1", "", "49.0", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.1", "78.5", "", "", "", "", "78.6"]} -{"pcdb_id": 8604, "brand_name": "Sime", "model_name": "Superior 40 MK.II", "model_qualifier": "", "winter_efficiency_pct": 77.0, "summer_efficiency_pct": 66.9, "comparative_hot_water_efficiency_pct": 48.8, "output_kw_max": 11.9, "final_year_of_manufacture": 2018, "raw": ["008604", "000213", "0", "2018/Mar/05 15:10", "Fonderie Sime S.p.A.", "Sime", "Superior 40 MK.II", "", "", "2001", "2018", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "8.7", "11.9", "", "", "77.0", "66.9", "", "48.8", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.2", "77.9", "", "", "", "", "78.2"]} -{"pcdb_id": 8605, "brand_name": "Sime", "model_name": "Planet Dewy 90", "model_qualifier": "", "winter_efficiency_pct": 87.4, "summer_efficiency_pct": 78.8, "comparative_hot_water_efficiency_pct": 55.4, "output_kw_max": 29.3, "final_year_of_manufacture": 2018, "raw": ["008605", "000213", "0", "2018/Mar/05 14:30", "Fonderie Sime S.p.A.", "Sime", "Planet Dewy 90", "", "", "2000", "2018", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "29.3", "29.3", "", "", "87.4", "78.8", "", "55.4", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.0", "95.7", "", "", "", "", "94.0"]} -{"pcdb_id": 8606, "brand_name": "Sime", "model_name": "Planet Dewy 110", "model_qualifier": "", "winter_efficiency_pct": 87.7, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 55.6, "output_kw_max": 29.3, "final_year_of_manufacture": 2018, "raw": ["008606", "000213", "0", "2018/Mar/05 14:27", "Fonderie Sime S.p.A.", "Sime", "Planet Dewy 110", "", "", "2000", "2018", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "29.3", "29.3", "", "", "87.7", "79.1", "", "55.6", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "96.0", "", "", "", "", "94.5"]} -{"pcdb_id": 8607, "brand_name": "Sime", "model_name": "Friendly Format 100E", "model_qualifier": "", "winter_efficiency_pct": 79.5, "summer_efficiency_pct": 69.4, "comparative_hot_water_efficiency_pct": 48.8, "output_kw_max": 29.0, "final_year_of_manufacture": 2018, "raw": ["008607", "000213", "0", "2018/Mar/05 14:08", "Fonderie Sime S.p.A.", "Sime", "Friendly Format 100E", "", "", "1999", "2018", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "29", "29", "", "", "79.5", "69.4", "", "48.8", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.9", "78.6", "", "", "", "", "79.4"]} -{"pcdb_id": 8608, "brand_name": "Sime", "model_name": "Super 90 MK.II", "model_qualifier": "", "winter_efficiency_pct": 80.2, "summer_efficiency_pct": 70.1, "comparative_hot_water_efficiency_pct": 49.3, "output_kw_max": 23.68, "final_year_of_manufacture": 2018, "raw": ["008608", "000213", "0", "2018/Mar/05 15:08", "Fonderie Sime S.p.A.", "Sime", "Super 90 MK.II", "", "", "2000", "2018", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "23.68", "23.68", "", "", "80.2", "70.1", "", "49.3", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.7", "80.1", "", "", "", "", "80.6"]} -{"pcdb_id": 8609, "brand_name": "Sime", "model_name": "Super 105 MK II", "model_qualifier": "", "winter_efficiency_pct": 79.5, "summer_efficiency_pct": 69.4, "comparative_hot_water_efficiency_pct": 48.8, "output_kw_max": 30.5, "final_year_of_manufacture": 2018, "raw": ["008609", "000213", "0", "2018/Mar/05 15:05", "Fonderie Sime S.p.A.", "Sime", "Super 105 MK II", "", "", "2000", "2018", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "30.5", "30.5", "", "", "79.5", "69.4", "", "48.8", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.9", "78.6", "", "", "", "", "79.4"]} -{"pcdb_id": 8613, "brand_name": "Boulter", "model_name": "Pathfinder GA", "model_qualifier": "70kW", "winter_efficiency_pct": 80.4, "summer_efficiency_pct": 70.3, "comparative_hot_water_efficiency_pct": 51.3, "output_kw_max": 70.0, "final_year_of_manufacture": null, "raw": ["008613", "000041", "0", "2012/Mar/27 10:12", "Boulter Boilers", "Boulter", "Pathfinder GA", "70kW", "", "2001", "obsolete", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "70", "70", "", "", "80.4", "70.3", "", "51.3", "", "2", "", "", "101", "1", "1", "10", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.6", "81.4", "", "", "", "", "81.6"]} -{"pcdb_id": 8614, "brand_name": "Boulter", "model_name": "Pathfinder GA", "model_qualifier": "60kW", "winter_efficiency_pct": 80.5, "summer_efficiency_pct": 70.4, "comparative_hot_water_efficiency_pct": 51.4, "output_kw_max": 60.0, "final_year_of_manufacture": null, "raw": ["008614", "000041", "0", "2012/Mar/27 10:12", "Boulter Boilers", "Boulter", "Pathfinder GA", "60kW", "", "2001", "obsolete", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "60", "60", "", "", "80.5", "70.4", "", "51.4", "", "2", "", "", "101", "1", "1", "10", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.6", "81.6", "", "", "", "", "81.8"]} -{"pcdb_id": 8620, "brand_name": "Worcester", "model_name": "Greenstar HE 12/22", "model_qualifier": "RS", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 78.9, "comparative_hot_water_efficiency_pct": 57.6, "output_kw_max": 21.1, "final_year_of_manufacture": 2008, "raw": ["008620", "000035", "0", "2020/Sep/02 14:16", "Worcester Heat Systems", "Worcester", "Greenstar HE 12/22", "RS", "49AS036R", "2001", "2008", "4", "1", "1", "1", "0", "", "", "2", "2", "2", "14.1", "21.1", "", "", "86.7", "78.9", "", "57.6", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "89.3", "92.2", "", "", "", "", "91.6"]} -{"pcdb_id": 8621, "brand_name": "Boulter", "model_name": "Camray 5", "model_qualifier": "150/200K", "winter_efficiency_pct": 85.3, "summer_efficiency_pct": 73.6, "comparative_hot_water_efficiency_pct": 53.7, "output_kw_max": 58.6, "final_year_of_manufacture": null, "raw": ["008621", "000041", "0", "2012/Mar/27 10:12", "Boulter Boilers", "Boulter", "Camray 5", "150/200K", "", "2001", "current", "4", "1", "1", "1", "0", "", "", "1", "3", "2", "44", "58.6", "", "", "85.3", "73.6", "", "53.7", "", "2", "", "", "201", "1", "1", "150", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.3", "85.3", "", "", "", "", "85.3"]} -{"pcdb_id": 8623, "brand_name": "Ikon", "model_name": "23 t", "model_qualifier": "", "winter_efficiency_pct": 79.6, "summer_efficiency_pct": 69.5, "comparative_hot_water_efficiency_pct": 48.9, "output_kw_max": 23.3, "final_year_of_manufacture": null, "raw": ["008623", "000020", "0", "2006/Jan/17 12:31", "Hermann Srl", "Ikon", "23 t", "", "GC 47-047-11", "2001", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "23.3", "23.3", "", "", "79.6", "69.5", "", "48.9", "", "2", "", "", "104", "1", "2", "150", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "83.0", "78.7", "", "", "", "", "79.6"]} -{"pcdb_id": 8624, "brand_name": "Ikon", "model_name": "28 t", "model_qualifier": "", "winter_efficiency_pct": 80.8, "summer_efficiency_pct": 70.7, "comparative_hot_water_efficiency_pct": 49.7, "output_kw_max": 28.1, "final_year_of_manufacture": null, "raw": ["008624", "000020", "0", "2006/Jan/17 12:31", "Hermann Srl", "Ikon", "28 t", "", "GC 47-047-12", "2001", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "28.1", "28.1", "", "", "80.8", "70.7", "", "49.7", "", "2", "", "", "104", "1", "2", "157", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "83.2", "81.1", "", "", "", "", "81.5"]} -{"pcdb_id": 8625, "brand_name": "Worcester", "model_name": "35 CDi II", "model_qualifier": "RSF", "winter_efficiency_pct": 79.4, "summer_efficiency_pct": 69.3, "comparative_hot_water_efficiency_pct": 48.7, "output_kw_max": 27.5, "final_year_of_manufacture": 2005, "raw": ["008625", "000035", "0", "2020/Sep/02 14:16", "Worcester Heat Systems", "Worcester", "35 CDi II", "RSF", "47 311 58", "2001", "2005", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "27.5", "27.5", "", "", "79.4", "69.3", "", "48.7", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.3", "78.9", "", "", "", "", "79.6"]} -{"pcdb_id": 8626, "brand_name": "Worcester", "model_name": "35 CDi II", "model_qualifier": "RSF", "winter_efficiency_pct": 81.3, "summer_efficiency_pct": 71.2, "comparative_hot_water_efficiency_pct": 50.1, "output_kw_max": 27.5, "final_year_of_manufacture": 2005, "raw": ["008626", "000035", "0", "2020/Sep/02 14:16", "Worcester Heat Systems", "Worcester", "35 CDi II", "RSF", "47 311 59", "2001", "2005", "2", "2", "1", "2", "0", "", "", "1", "2", "2", "27.5", "27.5", "", "", "81.3", "71.2", "", "50.1", "", "2", "0", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "84.2", "80.8", "", "", "", "", "81.4"]} -{"pcdb_id": 8627, "brand_name": "Firebird", "model_name": "Popular", "model_qualifier": "50-70", "winter_efficiency_pct": 85.0, "summer_efficiency_pct": 73.3, "comparative_hot_water_efficiency_pct": 53.6, "output_kw_max": 20.52, "final_year_of_manufacture": 2013, "raw": ["008627", "000047", "0", "2018/Jan/03 13:34", "Firebird Boilers", "Firebird", "Popular", "50-70", "", "", "2013", "4", "1", "1", "1", "0", "", "", "1", "2", "1", "14.65", "20.52", "", "", "85.0", "73.3", "", "53.6", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.5", "84.6", "", "", "", "", "84.8"]} -{"pcdb_id": 8628, "brand_name": "Firebird", "model_name": "Popular", "model_qualifier": "50-90", "winter_efficiency_pct": 86.1, "summer_efficiency_pct": 74.4, "comparative_hot_water_efficiency_pct": 54.4, "output_kw_max": 26.38, "final_year_of_manufacture": 2013, "raw": ["008628", "000047", "0", "2018/Jan/03 13:29", "Firebird Boilers", "Firebird", "Popular", "50-90", "", "", "2013", "4", "1", "1", "1", "0", "", "", "1", "2", "1", "14.65", "26.38", "", "", "86.1", "74.4", "", "54.4", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.8", "86.4", "", "", "", "", "86.3"]} -{"pcdb_id": 8629, "brand_name": "Firebird", "model_name": "Combi", "model_qualifier": "115", "winter_efficiency_pct": 84.0, "summer_efficiency_pct": 75.9, "comparative_hot_water_efficiency_pct": 43.2, "output_kw_max": 33.7, "final_year_of_manufacture": 2010, "raw": ["008629", "000047", "0", "2024/Jan/31 10:17", "Firebird Boilers", "Firebird", "Combi", "115", "", "1997", "2010", "4", "1", "1", "2", "0", "", "", "1", "2", "1", "33.7", "33.7", "", "", "84.0", "75.9", "", "43.2", "", "2", "", "", "203", "1", "1", "138", "0", "1", "2", "0", "25", "0", "25", "3", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.1", "85.5", "", "", "", "", "85.7"]} -{"pcdb_id": 8630, "brand_name": "Firebird", "model_name": "Combi", "model_qualifier": "90", "winter_efficiency_pct": 84.2, "summer_efficiency_pct": 76.1, "comparative_hot_water_efficiency_pct": 43.4, "output_kw_max": 26.38, "final_year_of_manufacture": 2013, "raw": ["008630", "000047", "0", "2024/Jan/31 10:17", "Firebird Boilers", "Firebird", "Combi", "90", "", "1997", "2013", "4", "1", "1", "2", "0", "", "", "1", "2", "1", "26.38", "26.38", "", "", "84.2", "76.1", "", "43.4", "", "2", "", "", "203", "1", "1", "138", "0", "1", "2", "0", "25", "0", "25", "3", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.6", "85.9", "", "", "", "", "86.0"]} -{"pcdb_id": 8631, "brand_name": "Firebird", "model_name": "Oylympic S", "model_qualifier": "50-70", "winter_efficiency_pct": 85.0, "summer_efficiency_pct": 73.3, "comparative_hot_water_efficiency_pct": 53.6, "output_kw_max": 20.52, "final_year_of_manufacture": 2010, "raw": ["008631", "000047", "0", "2012/Mar/27 10:12", "Firebird Boilers", "Firebird", "Oylympic S", "50-70", "", "", "2010", "4", "1", "1", "1", "0", "", "", "1", "2", "1", "14.65", "20.52", "", "", "85.0", "73.3", "", "53.6", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.5", "84.6", "", "", "", "", "84.8"]} -{"pcdb_id": 8632, "brand_name": "Firebird", "model_name": "Oylympic DeLuxe", "model_qualifier": "50-70", "winter_efficiency_pct": 85.0, "summer_efficiency_pct": 73.3, "comparative_hot_water_efficiency_pct": 53.6, "output_kw_max": 20.52, "final_year_of_manufacture": 2010, "raw": ["008632", "000047", "0", "2012/Mar/27 10:12", "Firebird Boilers", "Firebird", "Oylympic DeLuxe", "50-70", "", "", "2010", "4", "1", "1", "1", "0", "", "", "1", "2", "1", "14.65", "20.52", "", "", "85.0", "73.3", "", "53.6", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.5", "84.6", "", "", "", "", "84.8"]} -{"pcdb_id": 8633, "brand_name": "Firebird", "model_name": "Oylympic Boilerhouse", "model_qualifier": "50 - 70", "winter_efficiency_pct": 85.0, "summer_efficiency_pct": 73.3, "comparative_hot_water_efficiency_pct": 53.6, "output_kw_max": 20.52, "final_year_of_manufacture": 2010, "raw": ["008633", "000047", "0", "2012/Mar/27 10:12", "Firebird Boilers", "Firebird", "Oylympic Boilerhouse", "50 - 70", "", "", "2010", "4", "1", "1", "1", "0", "", "", "1", "2", "1", "14.65", "20.52", "", "", "85.0", "73.3", "", "53.6", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.5", "84.6", "", "", "", "", "84.8"]} -{"pcdb_id": 8634, "brand_name": "Firebird", "model_name": "Roomsealed Popular (Hideaway)", "model_qualifier": "50 - 90", "winter_efficiency_pct": 86.1, "summer_efficiency_pct": 74.4, "comparative_hot_water_efficiency_pct": 54.4, "output_kw_max": 26.38, "final_year_of_manufacture": 2010, "raw": ["008634", "000047", "0", "2012/Mar/27 10:12", "Firebird Boilers", "Firebird", "Roomsealed Popular (Hideaway)", "50 - 90", "", "", "2010", "4", "1", "1", "1", "0", "", "", "1", "2", "1", "14.65", "26.38", "", "", "86.1", "74.4", "", "54.4", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.8", "86.4", "", "", "", "", "86.3"]} -{"pcdb_id": 8635, "brand_name": "Firebird", "model_name": "Oylympic S", "model_qualifier": "70-90", "winter_efficiency_pct": 86.1, "summer_efficiency_pct": 74.4, "comparative_hot_water_efficiency_pct": 54.4, "output_kw_max": 26.38, "final_year_of_manufacture": 2010, "raw": ["008635", "000047", "0", "2012/Mar/27 10:12", "Firebird Boilers", "Firebird", "Oylympic S", "70-90", "", "", "2010", "4", "1", "1", "1", "0", "", "", "1", "2", "1", "20.52", "26.38", "", "", "86.1", "74.4", "", "54.4", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.8", "86.4", "", "", "", "", "86.3"]} -{"pcdb_id": 8636, "brand_name": "Firebird", "model_name": "Oylympic Deluxe", "model_qualifier": "70-90", "winter_efficiency_pct": 86.1, "summer_efficiency_pct": 74.4, "comparative_hot_water_efficiency_pct": 54.4, "output_kw_max": 26.38, "final_year_of_manufacture": 2010, "raw": ["008636", "000047", "0", "2012/Mar/27 10:12", "Firebird Boilers", "Firebird", "Oylympic Deluxe", "70-90", "", "", "2010", "4", "1", "1", "1", "0", "", "", "1", "2", "1", "20.52", "26.38", "", "", "86.1", "74.4", "", "54.4", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.8", "86.4", "", "", "", "", "86.3"]} -{"pcdb_id": 8637, "brand_name": "Firebird", "model_name": "Oylympic Boilerhouse", "model_qualifier": "70 - 90", "winter_efficiency_pct": 86.1, "summer_efficiency_pct": 74.4, "comparative_hot_water_efficiency_pct": 54.4, "output_kw_max": 26.38, "final_year_of_manufacture": 2010, "raw": ["008637", "000047", "0", "2012/Mar/27 10:12", "Firebird Boilers", "Firebird", "Oylympic Boilerhouse", "70 - 90", "", "", "2010", "4", "1", "1", "1", "0", "", "", "1", "2", "1", "20.52", "26.38", "", "", "86.1", "74.4", "", "54.4", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.8", "86.4", "", "", "", "", "86.3"]} -{"pcdb_id": 8638, "brand_name": "Ideal", "model_name": "Classic", "model_qualifier": "FF 3100", "winter_efficiency_pct": 78.9, "summer_efficiency_pct": 68.8, "comparative_hot_water_efficiency_pct": 50.3, "output_kw_max": 29.3, "final_year_of_manufacture": 2004, "raw": ["008638", "000008", "0", "2012/Mar/27 10:12", "Ideal Boilers", "Ideal", "Classic", "FF 3100", "GC No. 41 391 01", "2001", "2004", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "29.3", "29.3", "", "", "78.9", "68.8", "", "50.3", "", "2", "", "", "101", "1", "1", "100", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "80.5", "80.5", "", "", "", "", "80.5"]} -{"pcdb_id": 8639, "brand_name": "Ideal", "model_name": "Classic", "model_qualifier": "FF 380", "winter_efficiency_pct": 79.0, "summer_efficiency_pct": 68.9, "comparative_hot_water_efficiency_pct": 50.3, "output_kw_max": 23.4, "final_year_of_manufacture": 2004, "raw": ["008639", "000008", "0", "2012/Mar/27 10:12", "Ideal Boilers", "Ideal", "Classic", "FF 380", "GC No. 41 391 99", "2001", "2004", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "23.4", "23.4", "", "", "79.0", "68.9", "", "50.3", "", "2", "", "", "101", "1", "1", "100", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "80.6", "80.5", "", "", "", "", "80.6"]} -{"pcdb_id": 8640, "brand_name": "Ideal", "model_name": "Classic", "model_qualifier": "FF 370", "winter_efficiency_pct": 79.4, "summer_efficiency_pct": 69.3, "comparative_hot_water_efficiency_pct": 50.6, "output_kw_max": 20.5, "final_year_of_manufacture": 2004, "raw": ["008640", "000008", "0", "2012/Mar/27 10:12", "Ideal Boilers", "Ideal", "Classic", "FF 370", "GC No. 41 391 98", "2001", "2004", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "20.5", "20.5", "", "", "79.4", "69.3", "", "50.6", "", "2", "", "", "101", "1", "1", "100", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.2", "80.8", "", "", "", "", "80.9"]} -{"pcdb_id": 8641, "brand_name": "Ideal", "model_name": "Classic", "model_qualifier": "FF 360", "winter_efficiency_pct": 79.2, "summer_efficiency_pct": 69.1, "comparative_hot_water_efficiency_pct": 50.5, "output_kw_max": 17.6, "final_year_of_manufacture": 2004, "raw": ["008641", "000008", "0", "2012/Mar/27 10:12", "Ideal Boilers", "Ideal", "Classic", "FF 360", "GC No. 41 391 97", "2001", "2004", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "17.6", "17.6", "", "", "79.2", "69.1", "", "50.5", "", "2", "", "", "101", "1", "1", "100", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "80.8", "80.7", "", "", "", "", "80.7"]} -{"pcdb_id": 8642, "brand_name": "Ideal", "model_name": "Classic", "model_qualifier": "FF 350", "winter_efficiency_pct": 80.7, "summer_efficiency_pct": 70.6, "comparative_hot_water_efficiency_pct": 51.5, "output_kw_max": 14.7, "final_year_of_manufacture": 2004, "raw": ["008642", "000008", "0", "2012/Mar/27 10:12", "Ideal Boilers", "Ideal", "Classic", "FF 350", "GC No. 41 391 96", "2001", "2004", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "14.7", "14.7", "", "", "80.7", "70.6", "", "51.5", "", "2", "", "", "101", "1", "1", "100", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.3", "82.3", "", "", "", "", "82.3"]} -{"pcdb_id": 8643, "brand_name": "Ideal", "model_name": "Classic", "model_qualifier": "FF 340", "winter_efficiency_pct": 79.5, "summer_efficiency_pct": 69.4, "comparative_hot_water_efficiency_pct": 50.7, "output_kw_max": 11.7, "final_year_of_manufacture": 2004, "raw": ["008643", "000008", "0", "2012/Mar/27 10:12", "Ideal Boilers", "Ideal", "Classic", "FF 340", "GC No. 41 391 95", "2001", "2004", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "11.7", "11.7", "", "", "79.5", "69.4", "", "50.7", "", "2", "", "", "101", "1", "1", "100", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.0", "81.3", "", "", "", "", "81.2"]} -{"pcdb_id": 8644, "brand_name": "Ideal", "model_name": "Classic", "model_qualifier": "FF 330", "winter_efficiency_pct": 80.4, "summer_efficiency_pct": 70.3, "comparative_hot_water_efficiency_pct": 51.4, "output_kw_max": 8.8, "final_year_of_manufacture": 2004, "raw": ["008644", "000008", "0", "2012/Mar/27 10:12", "Ideal Boilers", "Ideal", "Classic", "FF 330", "GC No. 41 391 54", "2001", "2004", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "8.8", "8.8", "", "", "80.4", "70.3", "", "51.4", "", "2", "", "", "101", "1", "1", "100", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.9", "82.2", "", "", "", "", "82.1"]} -{"pcdb_id": 8645, "brand_name": "Ideal", "model_name": "Classic", "model_qualifier": "FF 360 LF", "winter_efficiency_pct": 80.0, "summer_efficiency_pct": 69.9, "comparative_hot_water_efficiency_pct": 51.1, "output_kw_max": 17.6, "final_year_of_manufacture": 2003, "raw": ["008645", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "Classic", "FF 360 LF", "GC No. 41 392 92", "2001", "2003", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "17.6", "17.6", "", "", "80.0", "69.9", "", "51.1", "", "2", "", "", "101", "1", "1", "100", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.9", "81.4", "", "", "", "", "81.5"]} -{"pcdb_id": 8646, "brand_name": "Ideal", "model_name": "Classic", "model_qualifier": "FF 350 LF", "winter_efficiency_pct": 79.3, "summer_efficiency_pct": 69.2, "comparative_hot_water_efficiency_pct": 50.6, "output_kw_max": 14.7, "final_year_of_manufacture": 2003, "raw": ["008646", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "Classic", "FF 350 LF", "GC No. 41 392 91", "2001", "2003", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "14.7", "14.7", "", "", "79.3", "69.2", "", "50.6", "", "2", "", "", "101", "1", "1", "100", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.1", "80.7", "", "", "", "", "80.8"]} -{"pcdb_id": 8647, "brand_name": "Ideal", "model_name": "Classic", "model_qualifier": "FF 340 LF", "winter_efficiency_pct": 80.0, "summer_efficiency_pct": 69.9, "comparative_hot_water_efficiency_pct": 51.0, "output_kw_max": 11.7, "final_year_of_manufacture": 2003, "raw": ["008647", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "Classic", "FF 340 LF", "GC No. 41 392 90", "2001", "2003", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "11.7", "11.7", "", "", "80.0", "69.9", "", "51.0", "", "2", "", "", "101", "1", "1", "100", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.7", "81.5", "", "", "", "", "81.5"]} -{"pcdb_id": 8648, "brand_name": "Ideal", "model_name": "Classic", "model_qualifier": "FF 380 P", "winter_efficiency_pct": 80.8, "summer_efficiency_pct": 70.7, "comparative_hot_water_efficiency_pct": 51.6, "output_kw_max": 23.5, "final_year_of_manufacture": 2004, "raw": ["008648", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "Classic", "FF 380 P", "GC No. 41 392 08", "2001", "2004", "2", "2", "1", "1", "0", "", "", "1", "2", "2", "23.5", "23.5", "", "", "80.8", "70.7", "", "51.6", "", "2", "0", "", "101", "1", "1", "100", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.4", "82.3", "", "", "", "", "82.4"]} -{"pcdb_id": 8649, "brand_name": "Ideal", "model_name": "Classic", "model_qualifier": "FF 360 P", "winter_efficiency_pct": 81.1, "summer_efficiency_pct": 71.0, "comparative_hot_water_efficiency_pct": 51.9, "output_kw_max": 17.6, "final_year_of_manufacture": 2004, "raw": ["008649", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "Classic", "FF 360 P", "GC No. 41 392 07", "2001", "2004", "2", "2", "1", "1", "0", "", "", "1", "2", "2", "17.6", "17.6", "", "", "81.1", "71.0", "", "51.9", "", "2", "0", "", "101", "1", "1", "100", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.9", "82.5", "", "", "", "", "82.6"]} -{"pcdb_id": 8650, "brand_name": "Ideal", "model_name": "Classic", "model_qualifier": "FF 350 P", "winter_efficiency_pct": 82.7, "summer_efficiency_pct": 72.6, "comparative_hot_water_efficiency_pct": 53.0, "output_kw_max": 14.7, "final_year_of_manufacture": 2004, "raw": ["008650", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "Classic", "FF 350 P", "GC No. 41 392 06", "2001", "2004", "2", "2", "1", "1", "0", "", "", "1", "2", "2", "14.7", "14.7", "", "", "82.7", "72.6", "", "53.0", "", "2", "0", "", "101", "1", "1", "100", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "84.7", "84.1", "", "", "", "", "84.2"]} -{"pcdb_id": 8651, "brand_name": "Ideal", "model_name": "Classic Slimline", "model_qualifier": "FF 360", "winter_efficiency_pct": 80.8, "summer_efficiency_pct": 70.7, "comparative_hot_water_efficiency_pct": 51.6, "output_kw_max": 17.6, "final_year_of_manufacture": 2004, "raw": ["008651", "000008", "0", "2012/Mar/27 10:12", "Ideal Boilers", "Ideal", "Classic Slimline", "FF 360", "GC No. 41 392 05", "2001", "2004", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "17.6", "17.6", "", "", "80.8", "70.7", "", "51.6", "", "2", "", "", "101", "1", "1", "100", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.4", "82.4", "", "", "", "", "82.4"]} -{"pcdb_id": 8652, "brand_name": "Ideal", "model_name": "Classic Slimline", "model_qualifier": "FF 350", "winter_efficiency_pct": 81.4, "summer_efficiency_pct": 71.3, "comparative_hot_water_efficiency_pct": 52.1, "output_kw_max": 14.7, "final_year_of_manufacture": 2004, "raw": ["008652", "000008", "0", "2012/Mar/27 10:12", "Ideal Boilers", "Ideal", "Classic Slimline", "FF 350", "GC No. 41 392 04", "2001", "2004", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "14.7", "14.7", "", "", "81.4", "71.3", "", "52.1", "", "2", "", "", "101", "1", "1", "100", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "83.0", "83.1", "", "", "", "", "83.1"]} -{"pcdb_id": 8653, "brand_name": "Ideal", "model_name": "Classic Slimline", "model_qualifier": "FF 340", "winter_efficiency_pct": 80.1, "summer_efficiency_pct": 70.0, "comparative_hot_water_efficiency_pct": 51.1, "output_kw_max": 11.7, "final_year_of_manufacture": 2004, "raw": ["008653", "000008", "0", "2012/Mar/27 10:12", "Ideal Boilers", "Ideal", "Classic Slimline", "FF 340", "GC No. 41 392 03", "2001", "2004", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "11.7", "11.7", "", "", "80.1", "70.0", "", "51.1", "", "2", "", "", "101", "1", "1", "100", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.8", "81.5", "", "", "", "", "81.6"]} -{"pcdb_id": 8654, "brand_name": "Ideal", "model_name": "Classic Slimline", "model_qualifier": "FF 330", "winter_efficiency_pct": 81.6, "summer_efficiency_pct": 71.5, "comparative_hot_water_efficiency_pct": 52.2, "output_kw_max": 8.8, "final_year_of_manufacture": 2004, "raw": ["008654", "000008", "0", "2012/Mar/27 10:12", "Ideal Boilers", "Ideal", "Classic Slimline", "FF 330", "GC No. 41 392 02", "2001", "2004", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "8.8", "8.8", "", "", "81.6", "71.5", "", "52.2", "", "2", "", "", "101", "1", "1", "100", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "83.1", "83.4", "", "", "", "", "83.4"]} -{"pcdb_id": 8655, "brand_name": "Ideal", "model_name": "Mexico Super", "model_qualifier": "4125 FF", "winter_efficiency_pct": 79.4, "summer_efficiency_pct": 69.3, "comparative_hot_water_efficiency_pct": 50.7, "output_kw_max": 36.6, "final_year_of_manufacture": 2006, "raw": ["008655", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "Mexico Super", "4125 FF", "GC No. 41 392 32", "2001", "2006", "1", "1", "1", "1", "0", "", "", "1", "2", "2", "36.6", "36.6", "", "", "79.4", "69.3", "", "50.7", "", "2", "", "", "101", "1", "1", "100", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "80.9", "81.2", "", "", "", "", "81.1"]} -{"pcdb_id": 8656, "brand_name": "Ideal", "model_name": "Mexico Super", "model_qualifier": "4100 FF", "winter_efficiency_pct": 79.8, "summer_efficiency_pct": 69.7, "comparative_hot_water_efficiency_pct": 50.9, "output_kw_max": 29.3, "final_year_of_manufacture": 2006, "raw": ["008656", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "Mexico Super", "4100 FF", "GC No. 41 392 31", "2001", "2006", "1", "1", "1", "1", "0", "", "", "1", "2", "2", "29.3", "29.3", "", "", "79.8", "69.7", "", "50.9", "", "2", "", "", "101", "1", "1", "100", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.5", "81.3", "", "", "", "", "81.3"]} -{"pcdb_id": 8657, "brand_name": "Ideal", "model_name": "Mexico Super", "model_qualifier": "480 FF", "winter_efficiency_pct": 80.8, "summer_efficiency_pct": 70.7, "comparative_hot_water_efficiency_pct": 51.7, "output_kw_max": 23.4, "final_year_of_manufacture": 2006, "raw": ["008657", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "Mexico Super", "480 FF", "GC No. 41 392 30", "2001", "2006", "1", "1", "1", "1", "0", "", "", "1", "2", "2", "23.4", "23.4", "", "", "80.8", "70.7", "", "51.7", "", "2", "", "", "101", "1", "1", "100", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.4", "82.5", "", "", "", "", "82.5"]} -{"pcdb_id": 8658, "brand_name": "Ideal", "model_name": "Mexico Super", "model_qualifier": "470 FF", "winter_efficiency_pct": 81.4, "summer_efficiency_pct": 71.3, "comparative_hot_water_efficiency_pct": 52.1, "output_kw_max": 20.5, "final_year_of_manufacture": 2006, "raw": ["008658", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "Mexico Super", "470 FF", "GC No. 41 392 29", "2001", "2006", "1", "1", "1", "1", "0", "", "", "1", "2", "2", "20.5", "20.5", "", "", "81.4", "71.3", "", "52.1", "", "2", "", "", "101", "1", "1", "100", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "83.2", "83.2", "", "", "", "", "83.2"]} -{"pcdb_id": 8659, "brand_name": "Ideal", "model_name": "Mexico Super", "model_qualifier": "460 FF", "winter_efficiency_pct": 80.1, "summer_efficiency_pct": 70.0, "comparative_hot_water_efficiency_pct": 51.1, "output_kw_max": 17.6, "final_year_of_manufacture": 2006, "raw": ["008659", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "Mexico Super", "460 FF", "GC No. 41 392 28", "2001", "2006", "1", "1", "1", "1", "0", "", "", "1", "2", "2", "17.6", "17.6", "", "", "80.1", "70.0", "", "51.1", "", "2", "", "", "101", "1", "1", "100", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.7", "81.6", "", "", "", "", "81.6"]} -{"pcdb_id": 8660, "brand_name": "Ideal", "model_name": "Mexico Super", "model_qualifier": "450 FF", "winter_efficiency_pct": 79.9, "summer_efficiency_pct": 69.8, "comparative_hot_water_efficiency_pct": 51.0, "output_kw_max": 14.7, "final_year_of_manufacture": 2006, "raw": ["008660", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "Mexico Super", "450 FF", "GC No. 41 392 27", "2001", "2006", "1", "1", "1", "1", "0", "", "", "1", "2", "2", "14.7", "14.7", "", "", "79.9", "69.8", "", "51.0", "", "2", "", "", "101", "1", "1", "100", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.7", "81.4", "", "", "", "", "81.4"]} -{"pcdb_id": 8661, "brand_name": "Ideal", "model_name": "Mexico Super", "model_qualifier": "440 FF", "winter_efficiency_pct": 79.2, "summer_efficiency_pct": 69.1, "comparative_hot_water_efficiency_pct": 50.5, "output_kw_max": 11.7, "final_year_of_manufacture": 2006, "raw": ["008661", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "Mexico Super", "440 FF", "GC No. 41 392 26", "2001", "2006", "1", "1", "1", "1", "0", "", "", "1", "2", "2", "11.7", "11.7", "", "", "79.2", "69.1", "", "50.5", "", "2", "", "", "101", "1", "1", "100", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.4", "80.3", "", "", "", "", "80.5"]} -{"pcdb_id": 8662, "brand_name": "British / Scottish Gas", "model_name": "RD1 3100", "model_qualifier": "", "winter_efficiency_pct": 78.9, "summer_efficiency_pct": 68.8, "comparative_hot_water_efficiency_pct": 50.3, "output_kw_max": 29.3, "final_year_of_manufacture": 2004, "raw": ["008662", "000008", "0", "2012/Mar/27 10:12", "Ideal Boilers", "British / Scottish Gas", "RD1 3100", "", "GC No. 41 392 25", "2001", "2004", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "29.3", "29.3", "", "", "78.9", "68.8", "", "50.3", "", "2", "", "", "101", "1", "1", "150", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "80.5", "80.5", "", "", "", "", "80.5"]} -{"pcdb_id": 8663, "brand_name": "British / Scottish Gas", "model_name": "RD1 380", "model_qualifier": "", "winter_efficiency_pct": 79.0, "summer_efficiency_pct": 68.9, "comparative_hot_water_efficiency_pct": 50.3, "output_kw_max": 23.4, "final_year_of_manufacture": 2004, "raw": ["008663", "000008", "0", "2012/Mar/27 10:12", "Ideal Boilers", "British / Scottish Gas", "RD1 380", "", "GC No. 41 392 24", "2001", "2004", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "23.4", "23.4", "", "", "79.0", "68.9", "", "50.3", "", "2", "", "", "101", "1", "1", "150", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "80.6", "80.5", "", "", "", "", "80.6"]} -{"pcdb_id": 8664, "brand_name": "British / Scottish Gas", "model_name": "RD1 370", "model_qualifier": "", "winter_efficiency_pct": 79.4, "summer_efficiency_pct": 69.3, "comparative_hot_water_efficiency_pct": 50.6, "output_kw_max": 20.5, "final_year_of_manufacture": 2004, "raw": ["008664", "000008", "0", "2012/Mar/27 10:12", "Ideal Boilers", "British / Scottish Gas", "RD1 370", "", "GC No. 41 392 21", "2001", "2004", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "20.5", "20.5", "", "", "79.4", "69.3", "", "50.6", "", "2", "", "", "101", "1", "1", "150", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.2", "80.8", "", "", "", "", "80.9"]} -{"pcdb_id": 8665, "brand_name": "British / Scottish Gas", "model_name": "RD1 360", "model_qualifier": "", "winter_efficiency_pct": 79.2, "summer_efficiency_pct": 69.1, "comparative_hot_water_efficiency_pct": 50.5, "output_kw_max": 17.6, "final_year_of_manufacture": 2004, "raw": ["008665", "000008", "0", "2012/Mar/27 10:12", "Ideal Boilers", "British / Scottish Gas", "RD1 360", "", "GC No. 41 392 20", "2001", "2004", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "17.6", "17.6", "", "", "79.2", "69.1", "", "50.5", "", "2", "", "", "101", "1", "1", "150", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "80.8", "80.7", "", "", "", "", "80.7"]} -{"pcdb_id": 8666, "brand_name": "British / Scottish Gas", "model_name": "RD1 350", "model_qualifier": "", "winter_efficiency_pct": 80.7, "summer_efficiency_pct": 70.6, "comparative_hot_water_efficiency_pct": 51.5, "output_kw_max": 14.7, "final_year_of_manufacture": 2004, "raw": ["008666", "000008", "0", "2012/Mar/27 10:12", "Ideal Boilers", "British / Scottish Gas", "RD1 350", "", "GC No. 41 392 17", "2001", "2004", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "14.7", "14.7", "", "", "80.7", "70.6", "", "51.5", "", "2", "", "", "101", "1", "1", "150", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.3", "82.3", "", "", "", "", "82.3"]} -{"pcdb_id": 8667, "brand_name": "British / Scottish Gas", "model_name": "RD1 340", "model_qualifier": "", "winter_efficiency_pct": 79.5, "summer_efficiency_pct": 69.4, "comparative_hot_water_efficiency_pct": 50.7, "output_kw_max": 11.7, "final_year_of_manufacture": 2004, "raw": ["008667", "000008", "0", "2012/Mar/27 10:12", "Ideal Boilers", "British / Scottish Gas", "RD1 340", "", "GC No. 41 392 16", "2001", "2004", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "11.7", "11.7", "", "", "79.5", "69.4", "", "50.7", "", "2", "", "", "101", "1", "1", "150", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.0", "81.3", "", "", "", "", "81.2"]} -{"pcdb_id": 8668, "brand_name": "British / Scottish Gas", "model_name": "RD1 330", "model_qualifier": "", "winter_efficiency_pct": 80.4, "summer_efficiency_pct": 70.3, "comparative_hot_water_efficiency_pct": 51.4, "output_kw_max": 8.8, "final_year_of_manufacture": 2004, "raw": ["008668", "000008", "0", "2012/Mar/27 10:12", "Ideal Boilers", "British / Scottish Gas", "RD1 330", "", "GC No. 41 392 13", "2001", "2004", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "8.8", "8.8", "", "", "80.4", "70.3", "", "51.4", "", "2", "", "", "101", "1", "1", "150", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.9", "82.2", "", "", "", "", "82.1"]} -{"pcdb_id": 8669, "brand_name": "British / Scottish Gas", "model_name": "RD2 4125", "model_qualifier": "", "winter_efficiency_pct": 79.4, "summer_efficiency_pct": 69.3, "comparative_hot_water_efficiency_pct": 50.7, "output_kw_max": 36.6, "final_year_of_manufacture": null, "raw": ["008669", "000008", "0", "2012/Mar/27 10:12", "Ideal Boilers", "British / Scottish Gas", "RD2 4125", "", "GC No. 41 392 73", "2001", "current", "1", "1", "1", "1", "0", "", "", "1", "2", "2", "36.6", "36.6", "", "", "79.4", "69.3", "", "50.7", "", "2", "", "", "101", "1", "1", "150", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "80.9", "81.2", "", "", "", "", "81.1"]} -{"pcdb_id": 8670, "brand_name": "British / Scottish Gas", "model_name": "RD2 4100", "model_qualifier": "", "winter_efficiency_pct": 79.8, "summer_efficiency_pct": 69.7, "comparative_hot_water_efficiency_pct": 50.9, "output_kw_max": 29.3, "final_year_of_manufacture": null, "raw": ["008670", "000008", "0", "2012/Mar/27 10:12", "Ideal Boilers", "British / Scottish Gas", "RD2 4100", "", "GC No. 41 392 72", "2001", "current", "1", "1", "1", "1", "0", "", "", "1", "2", "2", "29.3", "29.3", "", "", "79.8", "69.7", "", "50.9", "", "2", "", "", "101", "1", "1", "150", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.5", "81.3", "", "", "", "", "81.3"]} -{"pcdb_id": 8671, "brand_name": "British / Scottish Gas", "model_name": "RD2 480", "model_qualifier": "", "winter_efficiency_pct": 80.8, "summer_efficiency_pct": 70.7, "comparative_hot_water_efficiency_pct": 51.7, "output_kw_max": 23.4, "final_year_of_manufacture": null, "raw": ["008671", "000008", "0", "2012/Mar/27 10:12", "Ideal Boilers", "British / Scottish Gas", "RD2 480", "", "GC No. 41 392 37", "2001", "current", "1", "1", "1", "1", "0", "", "", "1", "2", "2", "23.4", "23.4", "", "", "80.8", "70.7", "", "51.7", "", "2", "", "", "101", "1", "1", "150", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.4", "82.5", "", "", "", "", "82.5"]} -{"pcdb_id": 8672, "brand_name": "British / Scottish Gas", "model_name": "RD2 470", "model_qualifier": "", "winter_efficiency_pct": 81.4, "summer_efficiency_pct": 71.3, "comparative_hot_water_efficiency_pct": 52.1, "output_kw_max": 20.5, "final_year_of_manufacture": null, "raw": ["008672", "000008", "0", "2012/Mar/27 10:12", "Ideal Boilers", "British / Scottish Gas", "RD2 470", "", "GC No. 41 392 36", "2001", "current", "1", "1", "1", "1", "0", "", "", "1", "2", "2", "20.5", "20.5", "", "", "81.4", "71.3", "", "52.1", "", "2", "", "", "101", "1", "1", "150", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "83.2", "83.2", "", "", "", "", "83.2"]} -{"pcdb_id": 8673, "brand_name": "British / Scottish Gas", "model_name": "RD2 460", "model_qualifier": "", "winter_efficiency_pct": 80.1, "summer_efficiency_pct": 70.0, "comparative_hot_water_efficiency_pct": 51.1, "output_kw_max": 17.6, "final_year_of_manufacture": null, "raw": ["008673", "000008", "0", "2012/Mar/27 10:12", "Ideal Boilers", "British / Scottish Gas", "RD2 460", "", "GC No. 41 392 35", "2001", "current", "1", "1", "1", "1", "0", "", "", "1", "2", "2", "17.6", "17.6", "", "", "80.1", "70.0", "", "51.1", "", "2", "", "", "101", "1", "1", "150", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.7", "81.6", "", "", "", "", "81.6"]} -{"pcdb_id": 8674, "brand_name": "British / Scottish Gas", "model_name": "RD2 450", "model_qualifier": "", "winter_efficiency_pct": 79.9, "summer_efficiency_pct": 69.8, "comparative_hot_water_efficiency_pct": 51.0, "output_kw_max": 14.7, "final_year_of_manufacture": null, "raw": ["008674", "000008", "0", "2012/Mar/27 10:12", "Ideal Boilers", "British / Scottish Gas", "RD2 450", "", "GC No. 41 392 34", "2001", "current", "1", "1", "1", "1", "0", "", "", "1", "2", "2", "14.7", "14.7", "", "", "79.9", "69.8", "", "51.0", "", "2", "", "", "101", "1", "1", "150", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.7", "81.4", "", "", "", "", "81.4"]} -{"pcdb_id": 8675, "brand_name": "British / Scottish Gas", "model_name": "RD2 440", "model_qualifier": "", "winter_efficiency_pct": 79.2, "summer_efficiency_pct": 69.1, "comparative_hot_water_efficiency_pct": 50.5, "output_kw_max": 11.7, "final_year_of_manufacture": null, "raw": ["008675", "000008", "0", "2012/Mar/27 10:12", "Ideal Boilers", "British / Scottish Gas", "RD2 440", "", "GC No. 41 392 33", "2001", "current", "1", "1", "1", "1", "0", "", "", "1", "2", "2", "11.7", "11.7", "", "", "79.2", "69.1", "", "50.5", "", "2", "", "", "101", "1", "1", "150", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.4", "80.3", "", "", "", "", "80.5"]} -{"pcdb_id": 8676, "brand_name": "Ideal", "model_name": "Classic", "model_qualifier": "RS 360", "winter_efficiency_pct": 79.9, "summer_efficiency_pct": 69.8, "comparative_hot_water_efficiency_pct": 51.0, "output_kw_max": 17.6, "final_year_of_manufacture": 2004, "raw": ["008676", "000008", "0", "2012/Mar/27 10:12", "Ideal Boilers", "Ideal", "Classic", "RS 360", "GC No. 41 392 12", "2001", "2004", "1", "2", "1", "1", "0", "", "", "1", "2", "1", "17.6", "17.6", "", "", "79.9", "69.8", "", "51.0", "", "2", "", "", "101", "1", "1", "10", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.9", "81.1", "", "", "", "", "81.2"]} -{"pcdb_id": 8677, "brand_name": "Ideal", "model_name": "Classic", "model_qualifier": "RS 350", "winter_efficiency_pct": 81.2, "summer_efficiency_pct": 71.1, "comparative_hot_water_efficiency_pct": 51.9, "output_kw_max": 14.7, "final_year_of_manufacture": 2004, "raw": ["008677", "000008", "0", "2012/Mar/27 10:12", "Ideal Boilers", "Ideal", "Classic", "RS 350", "GC No. 41 392 11", "2001", "2004", "1", "2", "1", "1", "0", "", "", "1", "2", "1", "14.7", "14.7", "", "", "81.2", "71.1", "", "51.9", "", "2", "", "", "101", "1", "1", "10", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.9", "82.6", "", "", "", "", "82.7"]} -{"pcdb_id": 8678, "brand_name": "Ideal", "model_name": "Classic", "model_qualifier": "RS 340", "winter_efficiency_pct": 79.8, "summer_efficiency_pct": 69.7, "comparative_hot_water_efficiency_pct": 50.9, "output_kw_max": 11.7, "final_year_of_manufacture": 2004, "raw": ["008678", "000008", "0", "2012/Mar/27 10:12", "Ideal Boilers", "Ideal", "Classic", "RS 340", "GC No. 41 392 10", "2001", "2004", "1", "2", "1", "1", "0", "", "", "1", "2", "1", "11.7", "11.7", "", "", "79.8", "69.7", "", "50.9", "", "2", "", "", "101", "1", "1", "10", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.2", "81.5", "", "", "", "", "81.5"]} -{"pcdb_id": 8679, "brand_name": "Ideal", "model_name": "Classic", "model_qualifier": "RS 330", "winter_efficiency_pct": 79.2, "summer_efficiency_pct": 69.1, "comparative_hot_water_efficiency_pct": 50.5, "output_kw_max": 8.8, "final_year_of_manufacture": 2004, "raw": ["008679", "000008", "0", "2012/Mar/27 10:12", "Ideal Boilers", "Ideal", "Classic", "RS 330", "GC No. 41 392 09", "2001", "2004", "1", "2", "1", "1", "0", "", "", "1", "2", "1", "8.8", "8.8", "", "", "79.2", "69.1", "", "50.5", "", "2", "", "", "101", "1", "1", "10", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.2", "80.5", "", "", "", "", "80.6"]} -{"pcdb_id": 8680, "brand_name": "Ideal", "model_name": "Mexico Super", "model_qualifier": "CF 4140", "winter_efficiency_pct": 79.5, "summer_efficiency_pct": 69.4, "comparative_hot_water_efficiency_pct": 50.7, "output_kw_max": 41.0, "final_year_of_manufacture": 2006, "raw": ["008680", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "Mexico Super", "CF 4140", "GC No. 41 392 87", "2001", "2006", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "41", "41.0", "", "", "79.5", "69.4", "", "50.7", "", "2", "", "", "101", "1", "1", "10", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.0", "80.3", "", "", "", "", "80.6"]} -{"pcdb_id": 8681, "brand_name": "Ideal", "model_name": "Mexico Super", "model_qualifier": "CF 4120", "winter_efficiency_pct": 79.9, "summer_efficiency_pct": 69.8, "comparative_hot_water_efficiency_pct": 50.9, "output_kw_max": 35.2, "final_year_of_manufacture": 2006, "raw": ["008681", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "Mexico Super", "CF 4120", "GC No. 41 392 86", "2001", "2006", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "35.2", "35.2", "", "", "79.9", "69.8", "", "50.9", "", "2", "", "", "101", "1", "1", "10", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.6", "81.3", "", "", "", "", "81.3"]} -{"pcdb_id": 8682, "brand_name": "Ideal", "model_name": "Mexico Super", "model_qualifier": "CF 495", "winter_efficiency_pct": 79.7, "summer_efficiency_pct": 69.6, "comparative_hot_water_efficiency_pct": 50.8, "output_kw_max": 27.8, "final_year_of_manufacture": 2006, "raw": ["008682", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "Mexico Super", "CF 495", "GC No. 41 392 85", "2001", "2006", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "27.8", "27.8", "", "", "79.7", "69.6", "", "50.8", "", "2", "", "", "101", "1", "1", "10", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.5", "81.1", "", "", "", "", "81.2"]} -{"pcdb_id": 8683, "brand_name": "Ideal", "model_name": "Mexico Super", "model_qualifier": "CF 475", "winter_efficiency_pct": 79.8, "summer_efficiency_pct": 69.7, "comparative_hot_water_efficiency_pct": 50.9, "output_kw_max": 22.0, "final_year_of_manufacture": 2006, "raw": ["008683", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "Mexico Super", "CF 475", "GC No. 41 392 84", "2001", "2006", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "22", "22.0", "", "", "79.8", "69.7", "", "50.9", "", "2", "", "", "101", "1", "1", "10", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.1", "81.6", "", "", "", "", "81.5"]} -{"pcdb_id": 8684, "brand_name": "Ideal", "model_name": "Mexico Super", "model_qualifier": "CF 465", "winter_efficiency_pct": 80.7, "summer_efficiency_pct": 70.6, "comparative_hot_water_efficiency_pct": 51.5, "output_kw_max": 19.1, "final_year_of_manufacture": 2006, "raw": ["008684", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "Mexico Super", "CF 465", "GC No. 41 392 83", "2001", "2006", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "19.1", "19.1", "", "", "80.7", "70.6", "", "51.5", "", "2", "", "", "101", "1", "1", "10", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.4", "82.2", "", "", "", "", "82.2"]} -{"pcdb_id": 8685, "brand_name": "Ideal", "model_name": "Mexico Super", "model_qualifier": "CF 455", "winter_efficiency_pct": 79.4, "summer_efficiency_pct": 69.3, "comparative_hot_water_efficiency_pct": 50.6, "output_kw_max": 16.1, "final_year_of_manufacture": 2006, "raw": ["008685", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "Mexico Super", "CF 455", "GC No. 41 392 82", "2001", "2006", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "16.1", "16.1", "", "", "79.4", "69.3", "", "50.6", "", "2", "", "", "101", "1", "1", "10", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.3", "80.7", "", "", "", "", "80.8"]} -{"pcdb_id": 8686, "brand_name": "Ideal", "model_name": "Mexico Super", "model_qualifier": "CF 445", "winter_efficiency_pct": 79.4, "summer_efficiency_pct": 69.3, "comparative_hot_water_efficiency_pct": 50.6, "output_kw_max": 13.2, "final_year_of_manufacture": 2006, "raw": ["008686", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "Mexico Super", "CF 445", "GC No. 41 392 81", "2001", "2006", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "13.2", "13.2", "", "", "79.4", "69.3", "", "50.6", "", "2", "", "", "101", "1", "1", "10", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.3", "80.6", "", "", "", "", "80.8"]} -{"pcdb_id": 8687, "brand_name": "Ideal", "model_name": "Mexico Slimline", "model_qualifier": "CF 440", "winter_efficiency_pct": 79.4, "summer_efficiency_pct": 69.3, "comparative_hot_water_efficiency_pct": 50.7, "output_kw_max": 11.7, "final_year_of_manufacture": 2006, "raw": ["008687", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "Mexico Slimline", "CF 440", "GC No.41 392 89", "2001", "2006", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "11.7", "11.7", "", "", "79.4", "69.3", "", "50.7", "", "2", "", "", "101", "1", "1", "10", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.1", "80.0", "", "", "", "", "80.4"]} -{"pcdb_id": 8688, "brand_name": "Ideal", "model_name": "Mexico Super", "model_qualifier": "RS 4125", "winter_efficiency_pct": 80.3, "summer_efficiency_pct": 70.2, "comparative_hot_water_efficiency_pct": 51.2, "output_kw_max": 36.6, "final_year_of_manufacture": 2006, "raw": ["008688", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "Mexico Super", "RS 4125", "GC No. 41 392 78", "2001", "2006", "1", "1", "1", "1", "0", "", "", "1", "2", "1", "36.6", "36.6", "", "", "80.3", "70.2", "", "51.2", "", "2", "", "", "101", "1", "1", "10", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.2", "81.5", "", "", "", "", "81.7"]} -{"pcdb_id": 8689, "brand_name": "Ideal", "model_name": "Mexico Super", "model_qualifier": "RS 4100", "winter_efficiency_pct": 79.9, "summer_efficiency_pct": 69.8, "comparative_hot_water_efficiency_pct": 51.0, "output_kw_max": 29.3, "final_year_of_manufacture": 2006, "raw": ["008689", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "Mexico Super", "RS 4100", "GC No. 41 392 79", "2001", "2006", "1", "1", "1", "1", "0", "", "", "1", "2", "1", "29.3", "29.3", "", "", "79.9", "69.8", "", "51.0", "", "2", "", "", "101", "1", "1", "10", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.8", "81.2", "", "", "", "", "81.3"]} -{"pcdb_id": 8690, "brand_name": "Ideal", "model_name": "Mexico Super", "model_qualifier": "RS 485", "winter_efficiency_pct": 80.0, "summer_efficiency_pct": 69.9, "comparative_hot_water_efficiency_pct": 51.0, "output_kw_max": 24.9, "final_year_of_manufacture": 2006, "raw": ["008690", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "Mexico Super", "RS 485", "GC No. 41 392 78", "2001", "2006", "1", "1", "1", "1", "0", "", "", "1", "2", "1", "24.9", "24.9", "", "", "80.0", "69.9", "", "51.0", "", "2", "", "", "101", "1", "1", "10", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.8", "81.4", "", "", "", "", "81.4"]} -{"pcdb_id": 8691, "brand_name": "Ideal", "model_name": "Mexico Super", "model_qualifier": "RS 470", "winter_efficiency_pct": 79.9, "summer_efficiency_pct": 69.8, "comparative_hot_water_efficiency_pct": 51.0, "output_kw_max": 20.5, "final_year_of_manufacture": 2006, "raw": ["008691", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "Mexico Super", "RS 470", "GC No. 41 392 77", "2001", "2006", "1", "1", "1", "1", "0", "", "", "1", "2", "1", "20.5", "20.5", "", "", "79.9", "69.8", "", "51.0", "", "2", "", "", "101", "1", "1", "10", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.9", "81.1", "", "", "", "", "81.2"]} -{"pcdb_id": 8692, "brand_name": "Ideal", "model_name": "Mexico Super", "model_qualifier": "RS 460", "winter_efficiency_pct": 79.9, "summer_efficiency_pct": 69.8, "comparative_hot_water_efficiency_pct": 50.9, "output_kw_max": 17.6, "final_year_of_manufacture": 2006, "raw": ["008692", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "Mexico Super", "RS 460", "GC No. 41 392 76", "2001", "2006", "1", "1", "1", "1", "0", "", "", "1", "2", "1", "17.6", "17.6", "", "", "79.9", "69.8", "", "50.9", "", "2", "", "", "101", "1", "1", "10", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.1", "81.8", "", "", "", "", "81.7"]} -{"pcdb_id": 8693, "brand_name": "Ideal", "model_name": "Mexico Super", "model_qualifier": "RS 450", "winter_efficiency_pct": 80.0, "summer_efficiency_pct": 69.9, "comparative_hot_water_efficiency_pct": 51.1, "output_kw_max": 14.7, "final_year_of_manufacture": 2006, "raw": ["008693", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "Mexico Super", "RS 450", "GC No. 41 392 75", "2001", "2006", "1", "1", "1", "1", "0", "", "", "1", "2", "1", "14.7", "14.7", "", "", "80.0", "69.9", "", "51.1", "", "2", "", "", "101", "1", "1", "10", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.1", "81.2", "", "", "", "", "81.4"]} -{"pcdb_id": 8694, "brand_name": "Ideal", "model_name": "Mexico Super", "model_qualifier": "RS 440", "winter_efficiency_pct": 79.5, "summer_efficiency_pct": 69.4, "comparative_hot_water_efficiency_pct": 50.7, "output_kw_max": 11.7, "final_year_of_manufacture": 2006, "raw": ["008694", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "Mexico Super", "RS 440", "GC No. 41 392 74", "2001", "2006", "1", "1", "1", "1", "0", "", "", "1", "2", "1", "11.7", "11.7", "", "", "79.5", "69.4", "", "50.7", "", "2", "", "", "101", "1", "1", "10", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.4", "80.8", "", "", "", "", "80.9"]} -{"pcdb_id": 8695, "brand_name": "Ideal", "model_name": "Mexico Slimline", "model_qualifier": "RS 445", "winter_efficiency_pct": 79.3, "summer_efficiency_pct": 69.2, "comparative_hot_water_efficiency_pct": 50.5, "output_kw_max": 13.2, "final_year_of_manufacture": null, "raw": ["008695", "000008", "0", "2012/Mar/27 10:12", "Ideal Boilers", "Ideal", "Mexico Slimline", "RS 445", "GC No.41 392 88", "2001", "current", "1", "1", "1", "1", "0", "", "", "1", "2", "1", "13.2", "13.2", "", "", "79.3", "69.2", "", "50.5", "", "2", "", "", "101", "1", "1", "10", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "80.9", "80.8", "", "", "", "", "80.8"]} -{"pcdb_id": 8696, "brand_name": "Vokera", "model_name": "Mynute", "model_qualifier": "28e", "winter_efficiency_pct": 79.1, "summer_efficiency_pct": 68.4, "comparative_hot_water_efficiency_pct": 50.0, "output_kw_max": 28.0, "final_year_of_manufacture": 2010, "raw": ["008696", "000011", "0", "2012/Mar/27 10:12", "Vokera", "Vokera", "Mynute", "28e", "", "2001", "2010", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "28", "28", "", "", "79.1", "68.4", "", "50.0", "", "2", "", "", "102", "1", "2", "125", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "83.0", "77.3", "", "", "", "", "78.4"]} -{"pcdb_id": 8697, "brand_name": "Vokera", "model_name": "Eclipse ESC", "model_qualifier": "226", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 56.1, "output_kw_max": 26.1, "final_year_of_manufacture": 2010, "raw": ["008697", "000011", "0", "2010/Oct/21 11:01", "Vokera", "Vokera", "Eclipse ESC", "226", "", "2001", "2010", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "26.1", "26.1", "", "", "88.4", "79.8", "", "56.1", "", "2", "", "", "104", "1", "2", "130", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.5", "97.7", "", "", "", "", "95.9"]} -{"pcdb_id": 8698, "brand_name": "Vokera", "model_name": "Eclipse ESS", "model_qualifier": "226", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 26.1, "final_year_of_manufacture": 2010, "raw": ["008698", "000011", "0", "2012/Mar/27 10:12", "Vokera", "Vokera", "Eclipse ESS", "226", "", "2001", "2010", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "26.1", "26.1", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "130", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.5", "97.7", "", "", "", "", "95.9"]} -{"pcdb_id": 8699, "brand_name": "Potterton", "model_name": "Powermax HE", "model_qualifier": "85 CPIH", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 81.2, "comparative_hot_water_efficiency_pct": 53.0, "output_kw_max": 24.0, "final_year_of_manufacture": 2010, "raw": ["008699", "000005", "0", "2024/Jan/31 10:17", "Baxi UK", "Potterton", "Powermax HE", "85 CPIH", "5106346", "2001", "2010", "1", "1", "1", "2", "0", "", "", "2", "2", "2", "24.0", "24.0", "", "", "88.3", "81.2", "", "53.0", "", "2", "", "", "106", "1", "2", "96", "1", "2", "2", "0", "85", "0", "45", "2", "60", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.7", "97.8", "", "", "", "", "95.8"]} -{"pcdb_id": 8700, "brand_name": "Potterton", "model_name": "Powermax HE", "model_qualifier": "115 CPIH", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 81.2, "comparative_hot_water_efficiency_pct": 50.7, "output_kw_max": 24.0, "final_year_of_manufacture": 2010, "raw": ["008700", "000005", "0", "2024/Jan/31 10:17", "Baxi UK", "Potterton", "Powermax HE", "115 CPIH", "5106350", "2001", "2010", "1", "1", "1", "2", "0", "", "", "2", "2", "2", "24.0", "24.0", "", "", "88.3", "81.2", "", "50.7", "", "2", "", "", "106", "1", "2", "96", "1", "2", "2", "0", "115", "0", "45", "2", "60", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.7", "97.8", "", "", "", "", "95.8"]} -{"pcdb_id": 8701, "brand_name": "Potterton", "model_name": "Powermax HE", "model_qualifier": "150 CPIH", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 81.3, "comparative_hot_water_efficiency_pct": 47.3, "output_kw_max": 24.0, "final_year_of_manufacture": 2010, "raw": ["008701", "000005", "0", "2024/Jan/31 10:17", "Baxi UK", "Potterton", "Powermax HE", "150 CPIH", "5106354", "2001", "2010", "1", "1", "1", "2", "0", "", "", "2", "2", "2", "24.0", "24.0", "", "", "88.3", "81.3", "", "47.3", "", "2", "", "", "106", "1", "2", "96", "1", "2", "2", "0", "150", "0", "45", "2", "60", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.7", "97.8", "", "", "", "", "95.8"]} -{"pcdb_id": 8702, "brand_name": "Potterton", "model_name": "Powermax HE", "model_qualifier": "85 CP", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 81.2, "comparative_hot_water_efficiency_pct": 53.0, "output_kw_max": 24.0, "final_year_of_manufacture": 2010, "raw": ["008702", "000005", "0", "2024/Jan/31 10:17", "Baxi UK", "Potterton", "Powermax HE", "85 CP", "5106344", "2001", "2010", "1", "1", "1", "2", "0", "", "", "2", "2", "2", "24.0", "24.0", "", "", "88.3", "81.2", "", "53.0", "", "2", "", "", "106", "1", "2", "96", "1", "2", "2", "0", "85", "0", "45", "2", "60", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.7", "97.8", "", "", "", "", "95.8"]} -{"pcdb_id": 8703, "brand_name": "Potterton", "model_name": "Powermax HE", "model_qualifier": "115 CP", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 81.2, "comparative_hot_water_efficiency_pct": 50.7, "output_kw_max": 24.0, "final_year_of_manufacture": 2010, "raw": ["008703", "000005", "0", "2024/Jan/31 10:17", "Baxi UK", "Potterton", "Powermax HE", "115 CP", "5106348", "2001", "2010", "1", "1", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "88.3", "81.2", "", "50.7", "", "2", "", "", "106", "1", "2", "96", "1", "2", "2", "0", "115", "0", "45", "2", "60", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.7", "97.8", "", "", "", "", "95.8"]} -{"pcdb_id": 8704, "brand_name": "Potterton", "model_name": "Powermax HE", "model_qualifier": "150 CP", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 81.3, "comparative_hot_water_efficiency_pct": 47.3, "output_kw_max": 24.0, "final_year_of_manufacture": 2010, "raw": ["008704", "000005", "0", "2024/Jan/31 10:17", "Baxi UK", "Potterton", "Powermax HE", "150 CP", "5106352", "2001", "2010", "1", "1", "1", "2", "0", "", "", "2", "2", "2", "24.0", "24.0", "", "", "88.3", "81.3", "", "47.3", "", "2", "", "", "106", "1", "2", "96", "1", "2", "2", "0", "150", "0", "45", "2", "60", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.7", "97.8", "", "", "", "", "95.8"]} -{"pcdb_id": 8705, "brand_name": "Worcester", "model_name": "25Si - LL", "model_qualifier": "RSF", "winter_efficiency_pct": 82.0, "summer_efficiency_pct": 71.9, "comparative_hot_water_efficiency_pct": 50.5, "output_kw_max": 25.0, "final_year_of_manufacture": 2002, "raw": ["008705", "000035", "0", "2002/Sep/27 13:17", "Worcester Heat Systems", "Worcester", "25Si - LL", "RSF", "47 311 50", "1999", "2002", "2", "2", "1", "2", "0", "", "", "1", "2", "2", "25", "25", "", "", "82.0", "71.9", "", "50.5", "", "2", "0", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "86.0", "81.6", "", "", "", "", "82.4"]} -{"pcdb_id": 8706, "brand_name": "Worcester", "model_name": "25Si - LL", "model_qualifier": "RSF", "winter_efficiency_pct": 78.9, "summer_efficiency_pct": 68.8, "comparative_hot_water_efficiency_pct": 48.4, "output_kw_max": 25.0, "final_year_of_manufacture": 2002, "raw": ["008706", "000035", "0", "2002/Sep/27 13:17", "Worcester Heat Systems", "Worcester", "25Si - LL", "RSF", "47 311 49", "1999", "2002", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "25", "25", "", "", "78.9", "68.8", "", "48.4", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "83.3", "77.2", "", "", "", "", "78.4"]} -{"pcdb_id": 8707, "brand_name": "Vokera", "model_name": "Eclipse ESS", "model_qualifier": "216", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 16.0, "final_year_of_manufacture": 2010, "raw": ["008707", "000011", "0", "2012/Mar/27 10:12", "Vokera", "Vokera", "Eclipse ESS", "216", "", "2001", "2010", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "16.0", "16.0", "", "", "88.2", "79.2", "", "57.8", "", "2", "", "", "102", "1", "2", "130", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "97.3", "", "", "", "", "95.5"]} -{"pcdb_id": 8709, "brand_name": "Worcester", "model_name": "24 CDi - L", "model_qualifier": "OF", "winter_efficiency_pct": 80.5, "summer_efficiency_pct": 70.4, "comparative_hot_water_efficiency_pct": 49.5, "output_kw_max": 24.0, "final_year_of_manufacture": 2005, "raw": ["008709", "000035", "0", "2020/Sep/02 14:16", "Worcester Heat Systems", "Worcester", "24 CDi - L", "OF", "47 311 33", "1997", "2005", "2", "2", "1", "2", "0", "", "", "1", "1", "1", "24", "24", "", "", "80.5", "70.4", "", "49.5", "", "2", "0", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "83.2", "80.3", "", "", "", "", "80.9"]} -{"pcdb_id": 8710, "brand_name": "Worcester", "model_name": "24 CDi - L", "model_qualifier": "OF", "winter_efficiency_pct": 79.0, "summer_efficiency_pct": 68.9, "comparative_hot_water_efficiency_pct": 48.4, "output_kw_max": 24.0, "final_year_of_manufacture": 2005, "raw": ["008710", "000035", "0", "2020/Sep/02 14:16", "Worcester Heat Systems", "Worcester", "24 CDi - L", "OF", "47 311 32", "1997", "2005", "1", "2", "1", "2", "0", "", "", "1", "1", "1", "24", "24", "", "", "79.0", "68.9", "", "48.4", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.3", "79.1", "", "", "", "", "79.5"]} -{"pcdb_id": 8711, "brand_name": "Ferroli", "model_name": "Sigma 20-40", "model_qualifier": "", "winter_efficiency_pct": 79.1, "summer_efficiency_pct": 69.0, "comparative_hot_water_efficiency_pct": 50.4, "output_kw_max": 11.7, "final_year_of_manufacture": 2005, "raw": ["008711", "000097", "0", "2012/Mar/27 10:12", "Ferroli SpA", "Ferroli", "Sigma 20-40", "", "", "2001", "2005", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "5.5", "11.7", "", "", "79.1", "69.0", "", "50.4", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.9", "79.6", "", "", "", "", "80.0"]} -{"pcdb_id": 8712, "brand_name": "Ferroli", "model_name": "Sigma", "model_qualifier": "40-60", "winter_efficiency_pct": 79.0, "summer_efficiency_pct": 68.9, "comparative_hot_water_efficiency_pct": 50.4, "output_kw_max": 17.6, "final_year_of_manufacture": 2005, "raw": ["008712", "000097", "0", "2012/Mar/27 10:12", "Ferroli SpA", "Ferroli", "Sigma", "40-60", "", "2001", "2005", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "11.4", "17.6", "", "", "79.0", "68.9", "", "50.4", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.2", "80.1", "", "", "", "", "80.3"]} -{"pcdb_id": 8713, "brand_name": "Ferroli", "model_name": "Sigma 60-100", "model_qualifier": "", "winter_efficiency_pct": 79.2, "summer_efficiency_pct": 69.1, "comparative_hot_water_efficiency_pct": 50.5, "output_kw_max": 29.3, "final_year_of_manufacture": 2005, "raw": ["008713", "000097", "0", "2012/Mar/27 10:12", "Ferroli SpA", "Ferroli", "Sigma 60-100", "", "", "2001", "2005", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "17.9", "29.3", "", "", "79.2", "69.1", "", "50.5", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.1", "79.6", "", "", "", "", "80.0"]} -{"pcdb_id": 8714, "brand_name": "Ferroli", "model_name": "Tempra 12", "model_qualifier": "", "winter_efficiency_pct": 79.1, "summer_efficiency_pct": 68.4, "comparative_hot_water_efficiency_pct": 49.9, "output_kw_max": 12.0, "final_year_of_manufacture": 2006, "raw": ["008714", "000097", "0", "2012/Mar/27 10:12", "Ferroli SpA", "Ferroli", "Tempra 12", "", "", "2001", "2006", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "12", "12", "", "", "79.1", "68.4", "", "49.9", "", "2", "", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.5", "78.7", "", "", "", "", "79.2"]} -{"pcdb_id": 8715, "brand_name": "Ferroli", "model_name": "Tempra 18", "model_qualifier": "", "winter_efficiency_pct": 79.1, "summer_efficiency_pct": 68.4, "comparative_hot_water_efficiency_pct": 50.0, "output_kw_max": 18.0, "final_year_of_manufacture": 2006, "raw": ["008715", "000097", "0", "2012/Mar/27 10:12", "Ferroli SpA", "Ferroli", "Tempra 18", "", "", "2001", "2006", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "18", "18", "", "", "79.1", "68.4", "", "50.0", "", "2", "", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.5", "78.7", "", "", "", "", "79.3"]} -{"pcdb_id": 8716, "brand_name": "Ferroli", "model_name": "Tempra 24", "model_qualifier": "", "winter_efficiency_pct": 79.0, "summer_efficiency_pct": 68.3, "comparative_hot_water_efficiency_pct": 49.9, "output_kw_max": 23.3, "final_year_of_manufacture": 2006, "raw": ["008716", "000097", "0", "2012/Mar/27 10:12", "Ferroli SpA", "Ferroli", "Tempra 24", "", "", "2001", "2006", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "23.3", "23.3", "", "", "79.0", "68.3", "", "49.9", "", "2", "", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.4", "78.7", "", "", "", "", "79.2"]} -{"pcdb_id": 8717, "brand_name": "Ferroli", "model_name": "Tempra 30", "model_qualifier": "", "winter_efficiency_pct": 79.1, "summer_efficiency_pct": 68.4, "comparative_hot_water_efficiency_pct": 50.0, "output_kw_max": 30.0, "final_year_of_manufacture": 2006, "raw": ["008717", "000097", "0", "2012/Mar/27 10:12", "Ferroli SpA", "Ferroli", "Tempra 30", "", "", "2001", "2006", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "30", "30", "", "", "79.1", "68.4", "", "50.0", "", "2", "", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.5", "78.7", "", "", "", "", "79.2"]} -{"pcdb_id": 8722, "brand_name": "Sime", "model_name": "Estelle 3", "model_qualifier": "", "winter_efficiency_pct": 84.5, "summer_efficiency_pct": 72.8, "comparative_hot_water_efficiency_pct": 53.2, "output_kw_max": 23.5, "final_year_of_manufacture": 2018, "raw": ["008722", "000213", "0", "2018/Feb/26 15:51", "Fonderie Sime S.p.A.", "Sime", "Estelle 3", "", "", "2000", "2018", "4", "1", "1", "1", "0", "", "", "1", "1", "1", "18.9", "23.5", "", "", "84.5", "72.8", "", "53.2", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "84.0", "85.0", "", "", "", "", "84.8"]} -{"pcdb_id": 8723, "brand_name": "Sime", "model_name": "Estelle 4", "model_qualifier": "", "winter_efficiency_pct": 84.7, "summer_efficiency_pct": 73.0, "comparative_hot_water_efficiency_pct": 53.3, "output_kw_max": 31.3, "final_year_of_manufacture": 2018, "raw": ["008723", "000213", "0", "2018/Feb/26 16:49", "Fonderie Sime S.p.A.", "Sime", "Estelle 4", "", "", "2000", "2018", "4", "1", "1", "1", "0", "", "", "1", "1", "1", "24.5", "31.3", "", "", "84.7", "73.0", "", "53.3", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "84.3", "85.1", "", "", "", "", "84.9"]} -{"pcdb_id": 8724, "brand_name": "Sime", "model_name": "Estelle 5", "model_qualifier": "", "winter_efficiency_pct": 84.9, "summer_efficiency_pct": 73.2, "comparative_hot_water_efficiency_pct": 53.5, "output_kw_max": 40.0, "final_year_of_manufacture": 2018, "raw": ["008724", "000213", "0", "2018/Feb/26 16:50", "Fonderie Sime S.p.A.", "Sime", "Estelle 5", "", "", "2000", "2018", "4", "1", "1", "1", "0", "", "", "1", "1", "1", "32.5", "40.0", "", "", "84.9", "73.2", "", "53.5", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "84.6", "85.2", "", "", "", "", "85.1"]} -{"pcdb_id": 8725, "brand_name": "Sime", "model_name": "Estelle 6", "model_qualifier": "", "winter_efficiency_pct": 85.0, "summer_efficiency_pct": 73.3, "comparative_hot_water_efficiency_pct": 53.6, "output_kw_max": 48.1, "final_year_of_manufacture": 2018, "raw": ["008725", "000213", "0", "2018/Feb/26 16:50", "Fonderie Sime S.p.A.", "Sime", "Estelle 6", "", "", "2000", "2018", "4", "1", "1", "1", "0", "", "", "1", "1", "1", "41.7", "48.1", "", "", "85.0", "73.3", "", "53.6", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "84.8", "85.3", "", "", "", "", "85.2"]} -{"pcdb_id": 8726, "brand_name": "Sime", "model_name": "Estelle 7", "model_qualifier": "", "winter_efficiency_pct": 85.2, "summer_efficiency_pct": 73.5, "comparative_hot_water_efficiency_pct": 53.7, "output_kw_max": 57.5, "final_year_of_manufacture": 2018, "raw": ["008726", "000213", "0", "2018/Feb/26 16:51", "Fonderie Sime S.p.A.", "Sime", "Estelle 7", "", "", "2000", "2018", "4", "1", "1", "1", "0", "", "", "1", "1", "1", "49.9", "57.5", "", "", "85.2", "73.5", "", "53.7", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.1", "85.4", "", "", "", "", "85.3"]} -{"pcdb_id": 8730, "brand_name": "Sime", "model_name": "Rondo 3", "model_qualifier": "", "winter_efficiency_pct": 84.5, "summer_efficiency_pct": 72.8, "comparative_hot_water_efficiency_pct": 53.2, "output_kw_max": 23.5, "final_year_of_manufacture": 2018, "raw": ["008730", "000213", "0", "2018/Feb/26 16:30", "Fonderie Sime S.p.A.", "Sime", "Rondo 3", "", "", "2000", "2018", "4", "1", "1", "1", "0", "", "", "1", "1", "1", "18.9", "23.5", "", "", "84.5", "72.8", "", "53.2", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "84.0", "85.0", "", "", "", "", "84.8"]} -{"pcdb_id": 8731, "brand_name": "Sime", "model_name": "Rondo 4", "model_qualifier": "", "winter_efficiency_pct": 84.7, "summer_efficiency_pct": 73.0, "comparative_hot_water_efficiency_pct": 53.3, "output_kw_max": 31.3, "final_year_of_manufacture": 2018, "raw": ["008731", "000213", "0", "2018/Feb/26 16:29", "Fonderie Sime S.p.A.", "Sime", "Rondo 4", "", "", "2000", "2018", "4", "1", "1", "1", "0", "", "", "1", "1", "1", "24.5", "31.3", "", "", "84.7", "73.0", "", "53.3", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "84.3", "85.1", "", "", "", "", "84.9"]} -{"pcdb_id": 8732, "brand_name": "Sime", "model_name": "Rondo 5", "model_qualifier": "", "winter_efficiency_pct": 84.9, "summer_efficiency_pct": 73.2, "comparative_hot_water_efficiency_pct": 53.5, "output_kw_max": 40.0, "final_year_of_manufacture": 2018, "raw": ["008732", "000213", "0", "2018/Feb/26 16:29", "Fonderie Sime S.p.A.", "Sime", "Rondo 5", "", "", "2000", "2018", "4", "1", "1", "1", "0", "", "", "1", "1", "1", "32.5", "40.0", "", "", "84.9", "73.2", "", "53.5", "", "2", "", "", "201", "1", "0", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "84.6", "85.2", "", "", "", "", "85.1"]} -{"pcdb_id": 8733, "brand_name": "Sime", "model_name": "Rondo 6", "model_qualifier": "", "winter_efficiency_pct": 85.0, "summer_efficiency_pct": 73.3, "comparative_hot_water_efficiency_pct": 53.6, "output_kw_max": 48.1, "final_year_of_manufacture": 2018, "raw": ["008733", "000213", "0", "2018/Feb/26 16:29", "Fonderie Sime S.p.A.", "Sime", "Rondo 6", "", "", "2000", "2018", "4", "1", "1", "1", "0", "", "", "1", "1", "1", "41.7", "48.1", "", "", "85.0", "73.3", "", "53.6", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "84.8", "85.3", "", "", "", "", "85.2"]} -{"pcdb_id": 8734, "brand_name": "Sime", "model_name": "Rondo 7", "model_qualifier": "", "winter_efficiency_pct": 85.2, "summer_efficiency_pct": 73.5, "comparative_hot_water_efficiency_pct": 53.7, "output_kw_max": 57.5, "final_year_of_manufacture": 2018, "raw": ["008734", "000213", "0", "2018/Feb/26 16:28", "Fonderie Sime S.p.A.", "Sime", "Rondo 7", "", "", "2000", "2018", "4", "1", "1", "1", "0", "", "", "1", "1", "1", "49.9", "57.5", "", "", "85.2", "73.5", "", "53.7", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.1", "85.4", "", "", "", "", "85.3"]} -{"pcdb_id": 8737, "brand_name": "Sime", "model_name": "RX 55 CE iono", "model_qualifier": "", "winter_efficiency_pct": 81.2, "summer_efficiency_pct": 71.1, "comparative_hot_water_efficiency_pct": 51.9, "output_kw_max": 60.7, "final_year_of_manufacture": 2018, "raw": ["008737", "000213", "0", "2018/Mar/05 15:03", "Fonderie Sime S.p.A.", "Sime", "RX 55 CE iono", "", "", "1998", "2018", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "60.7", "60.7", "", "", "81.2", "71.1", "", "51.9", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "83.0", "82.7", "", "", "", "", "82.8"]} -{"pcdb_id": 8738, "brand_name": "Sime", "model_name": "RX 48 CE iono", "model_qualifier": "", "winter_efficiency_pct": 81.2, "summer_efficiency_pct": 71.1, "comparative_hot_water_efficiency_pct": 51.9, "output_kw_max": 48.8, "final_year_of_manufacture": 2018, "raw": ["008738", "000213", "0", "2018/Mar/05 15:02", "Fonderie Sime S.p.A.", "Sime", "RX 48 CE iono", "", "", "1998", "2018", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "48.8", "48.8", "", "", "81.2", "71.1", "", "51.9", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "83.0", "82.7", "", "", "", "", "82.8"]} -{"pcdb_id": 8739, "brand_name": "Sime", "model_name": "RX 37 CE iono", "model_qualifier": "", "winter_efficiency_pct": 81.6, "summer_efficiency_pct": 71.5, "comparative_hot_water_efficiency_pct": 52.2, "output_kw_max": 39.1, "final_year_of_manufacture": 2018, "raw": ["008739", "000213", "0", "2018/Mar/05 15:01", "Fonderie Sime S.p.A.", "Sime", "RX 37 CE iono", "", "", "1998", "2018", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "39.1", "39.1", "", "", "81.6", "71.5", "", "52.2", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "80.7", "85.7", "", "", "", "", "84.7"]} -{"pcdb_id": 8755, "brand_name": "Sime", "model_name": "1 R 6 Freestanding", "model_qualifier": "", "winter_efficiency_pct": 83.4, "summer_efficiency_pct": 71.7, "comparative_hot_water_efficiency_pct": 52.4, "output_kw_max": 64.8, "final_year_of_manufacture": 2018, "raw": ["008755", "000213", "0", "2018/Feb/26 15:42", "Fonderie Sime S.p.A.", "Sime", "1 R 6 Freestanding", "", "", "1998", "2018", "4", "1", "1", "1", "0", "", "", "1", "1", "1", "64.8", "64.8", "", "", "83.4", "71.7", "", "52.4", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.8", "84.0", "", "", "", "", "83.7"]} -{"pcdb_id": 8756, "brand_name": "Sime", "model_name": "1 R 5 Freestanding", "model_qualifier": "", "winter_efficiency_pct": 83.1, "summer_efficiency_pct": 71.4, "comparative_hot_water_efficiency_pct": 52.1, "output_kw_max": 52.0, "final_year_of_manufacture": 2018, "raw": ["008756", "000213", "0", "2018/Feb/26 15:40", "Fonderie Sime S.p.A.", "Sime", "1 R 5 Freestanding", "", "", "1998", "2018", "4", "1", "1", "1", "0", "", "", "1", "1", "1", "52", "52", "", "", "83.1", "71.4", "", "52.1", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.5", "83.7", "", "", "", "", "83.4"]} -{"pcdb_id": 8757, "brand_name": "Sime", "model_name": "1 R 4 Freestanding", "model_qualifier": "", "winter_efficiency_pct": 82.7, "summer_efficiency_pct": 71.0, "comparative_hot_water_efficiency_pct": 51.9, "output_kw_max": 39.2, "final_year_of_manufacture": 2018, "raw": ["008757", "000213", "0", "2018/Feb/26 15:38", "Fonderie Sime S.p.A.", "Sime", "1 R 4 Freestanding", "", "", "1998", "2018", "4", "1", "1", "1", "0", "", "", "1", "1", "1", "39.2", "39.2", "", "", "82.7", "71.0", "", "51.9", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.2", "83.3", "", "", "", "", "83.1"]} -{"pcdb_id": 8758, "brand_name": "Worcester", "model_name": "Danesmoor Wall Mounted", "model_qualifier": "12/19 - R00 - GB - L", "winter_efficiency_pct": 85.5, "summer_efficiency_pct": 73.8, "comparative_hot_water_efficiency_pct": 53.9, "output_kw_max": 19.0, "final_year_of_manufacture": 2008, "raw": ["008758", "000035", "0", "2020/Sep/02 14:16", "Worcester Heat Systems", "Worcester", "Danesmoor Wall Mounted", "12/19 - R00 - GB - L", "C16424/1", "2001", "2008", "4", "2", "2", "1", "0", "", "", "1", "2", "2", "12", "19", "", "", "85.5", "73.8", "", "53.9", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.5", "85.6", "", "", "", "", "85.6"]} -{"pcdb_id": 8759, "brand_name": "Worcester", "model_name": "Danesmoor Utility", "model_qualifier": "32/50 - 000 - GB - Utility - L", "winter_efficiency_pct": 85.4, "summer_efficiency_pct": 73.7, "comparative_hot_water_efficiency_pct": 53.8, "output_kw_max": 50.0, "final_year_of_manufacture": 2008, "raw": ["008759", "000035", "0", "2020/Sep/02 14:16", "Worcester Heat Systems", "Worcester", "Danesmoor Utility", "32/50 - 000 - GB - Utility - L", "C16396/1", "2001", "2008", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "32", "50", "", "", "85.4", "73.7", "", "53.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.6", "85.2", "", "", "", "", "85.3"]} -{"pcdb_id": 8760, "brand_name": "Worcester", "model_name": "Danesmoor", "model_qualifier": "32/50 - 000 -GB - L", "winter_efficiency_pct": 85.4, "summer_efficiency_pct": 73.7, "comparative_hot_water_efficiency_pct": 53.8, "output_kw_max": 50.0, "final_year_of_manufacture": 2008, "raw": ["008760", "000035", "0", "2020/Sep/02 14:17", "Worcester Heat Systems", "Worcester", "Danesmoor", "32/50 - 000 -GB - L", "C16396/1", "2001", "2008", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "32", "50", "", "", "85.4", "73.7", "", "53.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.6", "85.2", "", "", "", "", "85.3"]} -{"pcdb_id": 8761, "brand_name": "Worcester", "model_name": "Danesmoor Utility", "model_qualifier": "50/70 - 000 - GB - Utility - L", "winter_efficiency_pct": 85.2, "summer_efficiency_pct": 73.5, "comparative_hot_water_efficiency_pct": 53.7, "output_kw_max": 70.0, "final_year_of_manufacture": 2008, "raw": ["008761", "000035", "0", "2020/Sep/02 14:17", "Worcester Heat Systems", "Worcester", "Danesmoor Utility", "50/70 - 000 - GB - Utility - L", "C16414/1", "2001", "2008", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "50", "70", "", "", "85.2", "73.5", "", "53.7", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.4", "85.0", "", "", "", "", "85.1"]} -{"pcdb_id": 8762, "brand_name": "Worcester", "model_name": "Danesmoor", "model_qualifier": "50/70 - 000 - GB - L", "winter_efficiency_pct": 85.2, "summer_efficiency_pct": 73.5, "comparative_hot_water_efficiency_pct": 53.7, "output_kw_max": 70.0, "final_year_of_manufacture": 2008, "raw": ["008762", "000035", "0", "2020/Sep/02 14:17", "Worcester Heat Systems", "Worcester", "Danesmoor", "50/70 - 000 - GB - L", "C16414/1", "2001", "2008", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "50", "70", "", "", "85.2", "73.5", "", "53.7", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.4", "85.0", "", "", "", "", "85.1"]} -{"pcdb_id": 8763, "brand_name": "Glow-worm", "model_name": "23c", "model_qualifier": "", "winter_efficiency_pct": 80.8, "summer_efficiency_pct": 70.7, "comparative_hot_water_efficiency_pct": 49.7, "output_kw_max": 23.6, "final_year_of_manufacture": 2003, "raw": ["008763", "000207", "0", "2006/Jan/17 12:55", "Hepworth Heating", "Glow-worm", "23c", "", "GC 47-047-18", "2000", "2003", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "23.6", "23.6", "", "", "80.8", "70.7", "", "49.7", "", "2", "", "", "104", "1", "2", "160", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.8", "81.3", "", "", "", "", "81.6"]} -{"pcdb_id": 8764, "brand_name": "Protherm", "model_name": "100EC", "model_qualifier": "", "winter_efficiency_pct": 80.2, "summer_efficiency_pct": 70.1, "comparative_hot_water_efficiency_pct": 49.3, "output_kw_max": 27.4, "final_year_of_manufacture": null, "raw": ["008764", "000020", "0", "2006/Jan/17 12:31", "Hepworth Heating", "Protherm", "100EC", "", "GC 47-920-33", "2000", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "27.4", "27.4", "", "", "80.2", "70.1", "", "49.3", "", "2", "", "", "104", "1", "2", "160", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.3", "80.5", "", "", "", "", "80.9"]} -{"pcdb_id": 8765, "brand_name": "Jaguar", "model_name": "28", "model_qualifier": "", "winter_efficiency_pct": 80.2, "summer_efficiency_pct": 70.1, "comparative_hot_water_efficiency_pct": 49.3, "output_kw_max": 27.4, "final_year_of_manufacture": null, "raw": ["008765", "000020", "0", "2006/Jan/17 12:31", "Hepworth Heating", "Jaguar", "28", "", "GC 47-047-17", "2000", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "27.4", "27.4", "", "", "80.2", "70.1", "", "49.3", "", "2", "", "", "104", "1", "2", "145", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.3", "80.5", "", "", "", "", "80.9"]} -{"pcdb_id": 8766, "brand_name": "Protherm", "model_name": "80 E", "model_qualifier": "", "winter_efficiency_pct": 79.6, "summer_efficiency_pct": 69.5, "comparative_hot_water_efficiency_pct": 48.9, "output_kw_max": 23.0, "final_year_of_manufacture": null, "raw": ["008766", "000020", "0", "2006/Jan/17 12:31", "Hepworth Heating", "Protherm", "80 E", "", "GC 47-920-17", "2000", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "23.0", "23.0", "", "", "79.6", "69.5", "", "48.9", "", "2", "", "", "104", "1", "2", "135", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.5", "80.1", "", "", "", "", "80.4"]} -{"pcdb_id": 8767, "brand_name": "Protherm", "model_name": "80 EC", "model_qualifier": "", "winter_efficiency_pct": 79.6, "summer_efficiency_pct": 69.5, "comparative_hot_water_efficiency_pct": 48.9, "output_kw_max": 23.0, "final_year_of_manufacture": null, "raw": ["008767", "000020", "0", "2006/Jan/17 12:31", "Hepworth Heating", "Protherm", "80 EC", "", "GC 47-920-34", "2000", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "23.0", "23.0", "", "", "79.6", "69.5", "", "48.9", "", "2", "", "", "104", "1", "2", "135", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.5", "80.1", "", "", "", "", "80.4"]} -{"pcdb_id": 8768, "brand_name": "Jaguar", "model_name": "23", "model_qualifier": "", "winter_efficiency_pct": 79.6, "summer_efficiency_pct": 69.5, "comparative_hot_water_efficiency_pct": 48.9, "output_kw_max": 23.0, "final_year_of_manufacture": null, "raw": ["008768", "000020", "0", "2006/Jan/17 12:31", "Hepworth Heating", "Jaguar", "23", "", "GC 47-047-16", "2000", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "23.0", "23.0", "", "", "79.6", "69.5", "", "48.9", "", "2", "", "", "104", "1", "2", "135", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.5", "80.1", "", "", "", "", "80.4"]} -{"pcdb_id": 8769, "brand_name": "Potterton", "model_name": "Statesman", "model_qualifier": "45/50L", "winter_efficiency_pct": 86.2, "summer_efficiency_pct": 74.5, "comparative_hot_water_efficiency_pct": 54.4, "output_kw_max": 15.0, "final_year_of_manufacture": 2007, "raw": ["008769", "000005", "0", "2012/Mar/27 10:12", "Baxi Potterton", "Potterton", "Statesman", "45/50L", "LVR", "2001", "2007", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "13", "15", "", "", "86.2", "74.5", "", "54.4", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.3", "86.1", "", "", "", "", "86.3"]} -{"pcdb_id": 8770, "brand_name": "Potterton", "model_name": "Statesman", "model_qualifier": "50/70L", "winter_efficiency_pct": 86.5, "summer_efficiency_pct": 74.8, "comparative_hot_water_efficiency_pct": 54.6, "output_kw_max": 20.0, "final_year_of_manufacture": 2007, "raw": ["008770", "000005", "0", "2012/Mar/27 10:12", "Baxi Potterton", "Potterton", "Statesman", "50/70L", "LVS", "2001", "2007", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "15", "20", "", "", "86.5", "74.8", "", "54.6", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.1", "86.9", "", "", "", "", "86.7"]} -{"pcdb_id": 8771, "brand_name": "Potterton", "model_name": "Statesman", "model_qualifier": "70/90L", "winter_efficiency_pct": 86.0, "summer_efficiency_pct": 74.3, "comparative_hot_water_efficiency_pct": 54.3, "output_kw_max": 26.0, "final_year_of_manufacture": 2007, "raw": ["008771", "000005", "0", "2012/Mar/27 10:12", "Baxi Potterton", "Potterton", "Statesman", "70/90L", "LVT", "2001", "2007", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "20", "26", "", "", "86.0", "74.3", "", "54.3", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.3", "86.8", "", "", "", "", "86.5"]} -{"pcdb_id": 8772, "brand_name": "Potterton", "model_name": "Statesman", "model_qualifier": "90/110L", "winter_efficiency_pct": 85.8, "summer_efficiency_pct": 74.1, "comparative_hot_water_efficiency_pct": 54.1, "output_kw_max": 32.0, "final_year_of_manufacture": 2007, "raw": ["008772", "000005", "0", "2012/Mar/27 10:12", "Baxi Potterton", "Potterton", "Statesman", "90/110L", "LV V", "2001", "2007", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "26", "32", "", "", "85.8", "74.1", "", "54.1", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.1", "86.5", "", "", "", "", "86.2"]} -{"pcdb_id": 8773, "brand_name": "Potterton", "model_name": "Statesman Flowsure Plus", "model_qualifier": "70/90L", "winter_efficiency_pct": 83.9, "summer_efficiency_pct": 75.8, "comparative_hot_water_efficiency_pct": 34.0, "output_kw_max": 26.0, "final_year_of_manufacture": 2007, "raw": ["008773", "000005", "0", "2024/Jan/31 10:17", "Baxi Potterton", "Potterton", "Statesman Flowsure Plus", "70/90L", "LWE", "2001", "2007", "4", "1", "1", "2", "0", "", "", "1", "1", "2", "20", "26", "", "", "83.9", "75.8", "", "34.0", "", "2", "", "", "203", "1", "1", "", "", "1", "2", "0", "40", "0", "13", "6", "75", ".45", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "84.4", "86.6", "", "", "", "", "86.2"]} -{"pcdb_id": 8774, "brand_name": "Potterton", "model_name": "Statesman Flowsure", "model_qualifier": "70/90L", "winter_efficiency_pct": 83.9, "summer_efficiency_pct": 74.4, "comparative_hot_water_efficiency_pct": 52.3, "output_kw_max": 26.0, "final_year_of_manufacture": 2007, "raw": ["008774", "000005", "0", "2010/Nov/19 09:22", "Baxi Potterton", "Potterton", "Statesman Flowsure", "70/90L", "LWD", "2001", "2007", "4", "1", "1", "2", "0", "", "", "1", "1", "2", "20", "26", "", "", "83.9", "74.4", "", "52.3", "", "2", "", "", "202", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "84.9", "86.5", "", "", "", "", "86.2"]} -{"pcdb_id": 8775, "brand_name": "Potterton", "model_name": "Statesman System", "model_qualifier": "70/90L", "winter_efficiency_pct": 86.0, "summer_efficiency_pct": 74.3, "comparative_hot_water_efficiency_pct": 54.3, "output_kw_max": 26.0, "final_year_of_manufacture": 2007, "raw": ["008775", "000005", "0", "2012/Mar/27 10:12", "Baxi Potterton", "Potterton", "Statesman System", "70/90L", "LWC", "2001", "2007", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "20", "26", "", "", "86.0", "74.3", "", "54.3", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.0", "87.0", "", "", "", "", "86.6"]} -{"pcdb_id": 8776, "brand_name": "Potterton", "model_name": "Statesman Utility", "model_qualifier": "110/130L", "winter_efficiency_pct": 85.4, "summer_efficiency_pct": 73.7, "comparative_hot_water_efficiency_pct": 53.8, "output_kw_max": 38.0, "final_year_of_manufacture": 2007, "raw": ["008776", "000005", "0", "2012/Mar/27 10:12", "Baxi Potterton", "Potterton", "Statesman Utility", "110/130L", "LWA", "2001", "2007", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "32", "38", "", "", "85.4", "73.7", "", "53.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.0", "85.7", "", "", "", "", "85.6"]} -{"pcdb_id": 8777, "brand_name": "Potterton", "model_name": "Statesman Utility", "model_qualifier": "130/150L", "winter_efficiency_pct": 86.4, "summer_efficiency_pct": 74.7, "comparative_hot_water_efficiency_pct": 54.6, "output_kw_max": 44.0, "final_year_of_manufacture": 2007, "raw": ["008777", "000005", "0", "2012/Mar/27 10:12", "Baxi Potterton", "Potterton", "Statesman Utility", "130/150L", "LWB", "2001", "2007", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "38", "44", "", "", "86.4", "74.7", "", "54.6", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.1", "86.8", "", "", "", "", "86.6"]} -{"pcdb_id": 8779, "brand_name": "Potterton", "model_name": "Statesman Utility", "model_qualifier": "50/70L", "winter_efficiency_pct": 86.5, "summer_efficiency_pct": 74.8, "comparative_hot_water_efficiency_pct": 54.6, "output_kw_max": 20.0, "final_year_of_manufacture": 2007, "raw": ["008779", "000005", "0", "2012/Mar/27 10:12", "Baxi Potterton", "Potterton", "Statesman Utility", "50/70L", "LV W", "2001", "2007", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "15", "20", "", "", "86.5", "74.8", "", "54.6", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.1", "86.9", "", "", "", "", "86.7"]} -{"pcdb_id": 8780, "brand_name": "Potterton", "model_name": "Statesman Utility", "model_qualifier": "70/90L", "winter_efficiency_pct": 86.0, "summer_efficiency_pct": 74.3, "comparative_hot_water_efficiency_pct": 54.3, "output_kw_max": 26.0, "final_year_of_manufacture": 2007, "raw": ["008780", "000005", "0", "2012/Mar/27 10:12", "Baxi Potterton", "Potterton", "Statesman Utility", "70/90L", "LVX", "2001", "2007", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "20", "26", "", "", "86.0", "74.3", "", "54.3", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.3", "86.8", "", "", "", "", "86.5"]} -{"pcdb_id": 8781, "brand_name": "Potterton", "model_name": "Statesman Utility", "model_qualifier": "90/110L", "winter_efficiency_pct": 85.8, "summer_efficiency_pct": 74.1, "comparative_hot_water_efficiency_pct": 54.1, "output_kw_max": 32.0, "final_year_of_manufacture": 2007, "raw": ["008781", "000005", "0", "2012/Mar/27 10:12", "Baxi Potterton", "Potterton", "Statesman Utility", "90/110L", "LVY", "2001", "2007", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "26", "32", "", "", "85.8", "74.1", "", "54.1", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.1", "86.5", "", "", "", "", "86.2"]} -{"pcdb_id": 8782, "brand_name": "Protherm", "model_name": "Protherm 60-80 CI", "model_qualifier": "", "winter_efficiency_pct": 79.2, "summer_efficiency_pct": 69.1, "comparative_hot_water_efficiency_pct": 50.5, "output_kw_max": 23.45, "final_year_of_manufacture": null, "raw": ["008782", "000020", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Protherm", "Protherm 60-80 CI", "", "41 047 66", "2001", "current", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "17.58", "23.45", "", "", "79.2", "69.1", "", "50.5", "", "2", "", "", "101", "1", "1", "71", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "80.6", "81.0", "", "", "", "", "80.9"]} -{"pcdb_id": 8783, "brand_name": "Protherm", "model_name": "Protherm 40-50 CI", "model_qualifier": "", "winter_efficiency_pct": 79.8, "summer_efficiency_pct": 69.7, "comparative_hot_water_efficiency_pct": 50.9, "output_kw_max": 14.65, "final_year_of_manufacture": null, "raw": ["008783", "000020", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Protherm", "Protherm 40-50 CI", "", "41 047 53", "2001", "current", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "11.72", "14.65", "", "", "79.8", "69.7", "", "50.9", "", "2", "", "", "101", "1", "1", "56", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.1", "80.6", "", "", "", "", "80.9"]} -{"pcdb_id": 8784, "brand_name": "Ikon", "model_name": "40-50 CI", "model_qualifier": "", "winter_efficiency_pct": 79.8, "summer_efficiency_pct": 69.7, "comparative_hot_water_efficiency_pct": 50.9, "output_kw_max": 14.65, "final_year_of_manufacture": null, "raw": ["008784", "000020", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Ikon", "40-50 CI", "", "41 047 67", "2001", "current", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "11.72", "14.65", "", "", "79.8", "69.7", "", "50.9", "", "2", "", "", "101", "1", "1", "56", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.1", "80.6", "", "", "", "", "80.9"]} -{"pcdb_id": 8785, "brand_name": "Ikon", "model_name": "60-80 CI", "model_qualifier": "", "winter_efficiency_pct": 79.2, "summer_efficiency_pct": 69.1, "comparative_hot_water_efficiency_pct": 50.5, "output_kw_max": 23.45, "final_year_of_manufacture": null, "raw": ["008785", "000020", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Ikon", "60-80 CI", "", "41 047 68", "2001", "current", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "17.58", "23.45", "", "", "79.2", "69.1", "", "50.5", "", "2", "", "", "101", "1", "1", "71", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "80.6", "81.0", "", "", "", "", "80.9"]} -{"pcdb_id": 8786, "brand_name": "Glow-worm", "model_name": "Micron 30 FF", "model_qualifier": "", "winter_efficiency_pct": 79.2, "summer_efficiency_pct": 69.1, "comparative_hot_water_efficiency_pct": 50.5, "output_kw_max": 8.79, "final_year_of_manufacture": null, "raw": ["008786", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Micron 30 FF", "", "41 047 46", "2001", "current", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "8.79", "8.79", "", "", "79.2", "69.1", "", "50.5", "", "2", "", "", "101", "1", "1", "66", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.5", "80.0", "", "", "", "", "80.3"]} -{"pcdb_id": 8787, "brand_name": "Glow-worm", "model_name": "Micron 40 FF", "model_qualifier": "", "winter_efficiency_pct": 79.6, "summer_efficiency_pct": 69.5, "comparative_hot_water_efficiency_pct": 50.8, "output_kw_max": 11.72, "final_year_of_manufacture": null, "raw": ["008787", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Micron 40 FF", "", "41 047 47", "2001", "current", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "8.8", "11.72", "", "", "79.6", "69.5", "", "50.8", "", "2", "", "", "101", "1", "1", "66", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.8", "80.6", "", "", "", "", "80.9"]} -{"pcdb_id": 8788, "brand_name": "Glow-worm", "model_name": "Micron 50FF", "model_qualifier": "", "winter_efficiency_pct": 79.8, "summer_efficiency_pct": 69.7, "comparative_hot_water_efficiency_pct": 50.9, "output_kw_max": 14.65, "final_year_of_manufacture": null, "raw": ["008788", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Micron 50FF", "", "41 047 48", "2001", "current", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "11.72", "14.65", "", "", "79.8", "69.7", "", "50.9", "", "2", "", "", "101", "1", "1", "71", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.4", "81.5", "", "", "", "", "81.4"]} -{"pcdb_id": 8789, "brand_name": "Glow-worm", "model_name": "Micron 60 FF", "model_qualifier": "", "winter_efficiency_pct": 79.7, "summer_efficiency_pct": 69.6, "comparative_hot_water_efficiency_pct": 50.8, "output_kw_max": 17.58, "final_year_of_manufacture": null, "raw": ["008789", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Micron 60 FF", "", "41 047 49", "2001", "current", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "14.65", "17.58", "", "", "79.7", "69.6", "", "50.8", "", "2", "", "", "101", "1", "1", "71", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.5", "81.0", "", "", "", "", "81.1"]} -{"pcdb_id": 8790, "brand_name": "Glow-worm", "model_name": "Micron 70 FF", "model_qualifier": "", "winter_efficiency_pct": 79.2, "summer_efficiency_pct": 69.1, "comparative_hot_water_efficiency_pct": 50.5, "output_kw_max": 20.51, "final_year_of_manufacture": null, "raw": ["008790", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Micron 70 FF", "", "41 047 50", "2001", "current", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "17.58", "20.51", "", "", "79.2", "69.1", "", "50.5", "", "2", "", "", "101", "1", "1", "81", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "80.3", "81.4", "", "", "", "", "81.2"]} -{"pcdb_id": 8791, "brand_name": "Glow-worm", "model_name": "Micron 80 FF", "model_qualifier": "", "winter_efficiency_pct": 79.2, "summer_efficiency_pct": 69.1, "comparative_hot_water_efficiency_pct": 50.5, "output_kw_max": 23.45, "final_year_of_manufacture": null, "raw": ["008791", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Micron 80 FF", "", "41 047 51", "2001", "current", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "20.51", "23.45", "", "", "79.2", "69.1", "", "50.5", "", "2", "", "", "101", "1", "1", "81", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.4", "80.3", "", "", "", "", "80.5"]} -{"pcdb_id": 8792, "brand_name": "Glow-worm", "model_name": "Micron 100FF", "model_qualifier": "", "winter_efficiency_pct": 80.4, "summer_efficiency_pct": 70.3, "comparative_hot_water_efficiency_pct": 51.4, "output_kw_max": 29.31, "final_year_of_manufacture": null, "raw": ["008792", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Micron 100FF", "", "41 047 52", "2001", "current", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "23.45", "29.31", "", "", "80.4", "70.3", "", "51.4", "", "2", "", "", "101", "1", "1", "71", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.1", "82.0", "", "", "", "", "82.0"]} -{"pcdb_id": 8793, "brand_name": "Glow-worm", "model_name": "Ultimate 40 FF", "model_qualifier": "", "winter_efficiency_pct": 79.6, "summer_efficiency_pct": 69.5, "comparative_hot_water_efficiency_pct": 50.8, "output_kw_max": 11.72, "final_year_of_manufacture": null, "raw": ["008793", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Ultimate 40 FF", "", "41 047 54", "2001", "current", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "10.26", "11.72", "", "", "79.6", "69.5", "", "50.8", "", "2", "", "", "101", "1", "1", "56", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "80.8", "81.6", "", "", "", "", "81.5"]} -{"pcdb_id": 8794, "brand_name": "Glow-worm", "model_name": "Ultimate 50 FF", "model_qualifier": "", "winter_efficiency_pct": 79.7, "summer_efficiency_pct": 69.6, "comparative_hot_water_efficiency_pct": 50.8, "output_kw_max": 14.65, "final_year_of_manufacture": null, "raw": ["008794", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Ultimate 50 FF", "", "41 047 55", "2001", "current", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "11.72", "14.65", "", "", "79.7", "69.6", "", "50.8", "", "2", "", "", "101", "1", "1", "56", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.0", "81.5", "", "", "", "", "81.4"]} -{"pcdb_id": 8795, "brand_name": "Glow-worm", "model_name": "Ultimate 60 FF", "model_qualifier": "", "winter_efficiency_pct": 80.3, "summer_efficiency_pct": 70.2, "comparative_hot_water_efficiency_pct": 51.2, "output_kw_max": 17.59, "final_year_of_manufacture": null, "raw": ["008795", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Ultimate 60 FF", "", "41 047 56", "2001", "current", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "14.65", "17.59", "", "", "80.3", "70.2", "", "51.2", "", "2", "", "", "101", "1", "1", "71", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.7", "82.0", "", "", "", "", "81.9"]} -{"pcdb_id": 8796, "brand_name": "Glow-worm", "model_name": "Ultimate 70 FF", "model_qualifier": "", "winter_efficiency_pct": 80.2, "summer_efficiency_pct": 70.1, "comparative_hot_water_efficiency_pct": 51.2, "output_kw_max": 20.52, "final_year_of_manufacture": null, "raw": ["008796", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Ultimate 70 FF", "", "41 319 59", "2001", "current", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "17.58", "20.52", "", "", "80.2", "70.1", "", "51.2", "", "2", "", "", "101", "1", "1", "71", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.7", "81.8", "", "", "", "", "81.8"]} -{"pcdb_id": 8797, "brand_name": "Glow-worm", "model_name": "Ultimate 80 FF", "model_qualifier": "", "winter_efficiency_pct": 80.3, "summer_efficiency_pct": 70.2, "comparative_hot_water_efficiency_pct": 51.2, "output_kw_max": 23.45, "final_year_of_manufacture": null, "raw": ["008797", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Ultimate 80 FF", "", "41 047 59", "2001", "current", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "20.52", "23.45", "", "", "80.3", "70.2", "", "51.2", "", "2", "", "", "101", "1", "1", "71", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.7", "82.0", "", "", "", "", "81.9"]} -{"pcdb_id": 8798, "brand_name": "Glow-worm", "model_name": "Ultimate 100 FF", "model_qualifier": "", "winter_efficiency_pct": 80.4, "summer_efficiency_pct": 70.3, "comparative_hot_water_efficiency_pct": 51.4, "output_kw_max": 29.31, "final_year_of_manufacture": null, "raw": ["008798", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Ultimate 100 FF", "", "41 047 60", "2001", "current", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "23.45", "29.31", "", "", "80.4", "70.3", "", "51.4", "", "2", "", "", "101", "1", "1", "71", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.1", "82.0", "", "", "", "", "82.0"]} -{"pcdb_id": 8799, "brand_name": "Glow-worm", "model_name": "45/4 BBU", "model_qualifier": "", "winter_efficiency_pct": 79.3, "summer_efficiency_pct": 69.2, "comparative_hot_water_efficiency_pct": 50.5, "output_kw_max": 13.19, "final_year_of_manufacture": 2003, "raw": ["008799", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "45/4 BBU", "", "44 047 06", "2001", "2003", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "8.79", "13.19", "", "", "79.3", "69.2", "", "50.5", "", "2", "", "", "101", "1", "1", "8", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "80.8", "80.9", "", "", "", "", "80.9"]} -{"pcdb_id": 8800, "brand_name": "Glow-worm", "model_name": "54/4 BBU", "model_qualifier": "", "winter_efficiency_pct": 79.8, "summer_efficiency_pct": 69.7, "comparative_hot_water_efficiency_pct": 50.9, "output_kw_max": 15.83, "final_year_of_manufacture": 2003, "raw": ["008800", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "54/4 BBU", "", "44 047 05", "2001", "2003", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "13.19", "15.83", "", "", "79.8", "69.7", "", "50.9", "", "2", "", "", "101", "1", "1", "8", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "80.9", "81.9", "", "", "", "", "81.7"]} -{"pcdb_id": 8801, "brand_name": "Saunier Duval", "model_name": "Xeon 40ff", "model_qualifier": "", "winter_efficiency_pct": 79.6, "summer_efficiency_pct": 69.5, "comparative_hot_water_efficiency_pct": 50.8, "output_kw_max": 11.72, "final_year_of_manufacture": null, "raw": ["008801", "000206", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Saunier Duval", "Xeon 40ff", "", "41 920 40", "2001", "current", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "10.26", "11.72", "", "", "79.6", "69.5", "", "50.8", "", "2", "", "", "101", "1", "1", "56", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "80.8", "81.6", "", "", "", "", "81.5"]} -{"pcdb_id": 8802, "brand_name": "Saunier Duval", "model_name": "Xeon 50ff", "model_qualifier": "", "winter_efficiency_pct": 79.7, "summer_efficiency_pct": 69.6, "comparative_hot_water_efficiency_pct": 50.8, "output_kw_max": 14.65, "final_year_of_manufacture": 2003, "raw": ["008802", "000206", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Saunier Duval", "Xeon 50ff", "", "41 920 41", "2001", "2003", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "11.72", "14.65", "", "", "79.7", "69.6", "", "50.8", "", "2", "", "", "101", "1", "1", "56", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.0", "81.5", "", "", "", "", "81.4"]} -{"pcdb_id": 8803, "brand_name": "Saunier Duval", "model_name": "Xeon 60ff", "model_qualifier": "", "winter_efficiency_pct": 80.3, "summer_efficiency_pct": 70.2, "comparative_hot_water_efficiency_pct": 51.2, "output_kw_max": 17.59, "final_year_of_manufacture": 2003, "raw": ["008803", "000206", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Saunier Duval", "Xeon 60ff", "", "41 920 42", "2001", "2003", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "14.65", "17.59", "", "", "80.3", "70.2", "", "51.2", "", "2", "", "", "101", "1", "1", "71", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.7", "82.0", "", "", "", "", "81.9"]} -{"pcdb_id": 8804, "brand_name": "Saunier Duval", "model_name": "Xeon 80 ff", "model_qualifier": "", "winter_efficiency_pct": 80.3, "summer_efficiency_pct": 70.2, "comparative_hot_water_efficiency_pct": 51.2, "output_kw_max": 23.45, "final_year_of_manufacture": null, "raw": ["008804", "000206", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Saunier Duval", "Xeon 80 ff", "", "41 920 43", "2001", "current", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "20.52", "23.45", "", "", "80.3", "70.2", "", "51.2", "", "2", "", "", "101", "1", "1", "71", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.7", "82.0", "", "", "", "", "81.9"]} -{"pcdb_id": 8805, "brand_name": "Grant", "model_name": "Vortex", "model_qualifier": "15", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 58.8, "output_kw_max": 15.0, "final_year_of_manufacture": null, "raw": ["008805", "000048", "0", "2012/Mar/27 10:12", "Grant Engineering", "Grant", "Vortex", "15", "", "2002", "current", "4", "1", "1", "1", "0", "", "", "2", "2", "2", "15", "15", "", "", "88.3", "80.5", "", "58.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "93.5", "94.5", "", "", "", "", "94.3"]} -{"pcdb_id": 8806, "brand_name": "Grant", "model_name": "Vortex", "model_qualifier": "20", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 80.9, "comparative_hot_water_efficiency_pct": 59.1, "output_kw_max": 20.0, "final_year_of_manufacture": null, "raw": ["008806", "000048", "0", "2012/Mar/27 10:12", "Grant Engineering", "Grant", "Vortex", "20", "", "2002", "current", "4", "1", "1", "1", "0", "", "", "2", "2", "2", "20", "20", "", "", "88.7", "80.9", "", "59.1", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "93.9", "95.3", "", "", "", "", "95.0"]} -{"pcdb_id": 8807, "brand_name": "Grant", "model_name": "Vortex", "model_qualifier": "26", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 81.3, "comparative_hot_water_efficiency_pct": 59.4, "output_kw_max": 26.0, "final_year_of_manufacture": null, "raw": ["008807", "000048", "0", "2012/Mar/27 10:12", "Grant Engineering", "Grant", "Vortex", "26", "", "2002", "current", "4", "1", "1", "1", "0", "", "", "2", "2", "2", "26", "26", "", "", "89.1", "81.3", "", "59.4", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "93.6", "96.4", "", "", "", "", "95.9"]} -{"pcdb_id": 8808, "brand_name": "Grant", "model_name": "Vortex", "model_qualifier": "15 S", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 58.8, "output_kw_max": 15.0, "final_year_of_manufacture": null, "raw": ["008808", "000048", "0", "2012/Mar/27 10:12", "Grant Engineering", "Grant", "Vortex", "15 S", "", "2002", "current", "4", "1", "1", "1", "0", "", "", "2", "2", "2", "15", "15", "", "", "88.3", "80.5", "", "58.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "93.5", "94.5", "", "", "", "", "94.3"]} -{"pcdb_id": 8809, "brand_name": "Grant", "model_name": "Vortex", "model_qualifier": "20 S", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 80.9, "comparative_hot_water_efficiency_pct": 59.1, "output_kw_max": 20.0, "final_year_of_manufacture": null, "raw": ["008809", "000048", "0", "2012/Mar/27 10:12", "Grant Engineering", "Grant", "Vortex", "20 S", "", "2002", "current", "4", "1", "1", "1", "0", "", "", "2", "2", "2", "20", "20", "", "", "88.7", "80.9", "", "59.1", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "93.9", "95.3", "", "", "", "", "95.0"]} -{"pcdb_id": 8810, "brand_name": "Grant", "model_name": "Vortex", "model_qualifier": "26 S", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 81.3, "comparative_hot_water_efficiency_pct": 59.4, "output_kw_max": 26.0, "final_year_of_manufacture": null, "raw": ["008810", "000048", "0", "2012/Mar/27 10:12", "Grant Engineering", "Grant", "Vortex", "26 S", "", "2002", "current", "4", "1", "1", "1", "0", "", "", "2", "2", "2", "26", "26", "", "", "89.1", "81.3", "", "59.4", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "93.6", "96.4", "", "", "", "", "95.9"]} -{"pcdb_id": 8811, "brand_name": "Lamborghini", "model_name": "Futuria", "model_qualifier": "24 MCW Top U/GB", "winter_efficiency_pct": 87.6, "summer_efficiency_pct": 78.6, "comparative_hot_water_efficiency_pct": 57.4, "output_kw_max": 25.0, "final_year_of_manufacture": null, "raw": ["008811", "000214", "0", "2012/Mar/27 10:12", "Lamborghini Calor SpA", "Lamborghini", "Futuria", "24 MCW Top U/GB", "900170-1", "1998", "current", "1", "1", "1", "1", "0", "", "", "2", "2", "2", "25.0", "25.0", "", "", "87.6", "78.6", "", "57.4", "", "2", "", "", "102", "1", "2", "274", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.4", "95.7", "", "", "", "", "94.3"]} -{"pcdb_id": 8812, "brand_name": "Lamborghini", "model_name": "Xilo", "model_qualifier": "20 MCS W Top U/GB", "winter_efficiency_pct": 77.5, "summer_efficiency_pct": 67.4, "comparative_hot_water_efficiency_pct": 47.4, "output_kw_max": 22.75, "final_year_of_manufacture": null, "raw": ["008812", "000214", "0", "2006/Jan/17 12:31", "Lamborghini Calor SpA", "Lamborghini", "Xilo", "20 MCS W Top U/GB", "902820-1", "2000", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "22.75", "22.75", "", "", "77.5", "67.4", "", "47.4", "", "2", "", "", "104", "1", "2", "150", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.0", "75.3", "", "", "", "", "76.6"]} -{"pcdb_id": 8813, "brand_name": "Lamborghini", "model_name": "Xilo D", "model_qualifier": "24 MCS W Top U/GB", "winter_efficiency_pct": 79.8, "summer_efficiency_pct": 69.7, "comparative_hot_water_efficiency_pct": 49.0, "output_kw_max": 27.48, "final_year_of_manufacture": null, "raw": ["008813", "000214", "0", "2006/Jan/17 12:31", "Lamborghini Calor SpA", "Lamborghini", "Xilo D", "24 MCS W Top U/GB", "903790", "2001", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "27.48", "27.48", "", "", "79.8", "69.7", "", "49.0", "", "2", "", "", "104", "1", "2", "175", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.0", "80.1", "", "", "", "", "80.5"]} -{"pcdb_id": 8814, "brand_name": "Lamborghini", "model_name": "Vela X", "model_qualifier": "24 MBS W Top/GB", "winter_efficiency_pct": 79.6, "summer_efficiency_pct": 70.5, "comparative_hot_water_efficiency_pct": 38.1, "output_kw_max": 27.8, "final_year_of_manufacture": null, "raw": ["008814", "000214", "0", "2024/Jan/31 10:17", "Lamborghini Calor SpA", "Lamborghini", "Vela X", "24 MBS W Top/GB", "903200", "2001", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "27.8", "27.8", "", "", "79.6", "70.5", "", "38.1", "", "2", "", "", "106", "1", "2", "153", "0", "1", "1", "0", "67.5", "0", "30", "1", "60", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.3", "78.7", "", "", "", "", "79.4"]} -{"pcdb_id": 8815, "brand_name": "Lamborghini", "model_name": "ALBA", "model_qualifier": "24 ASB", "winter_efficiency_pct": 79.6, "summer_efficiency_pct": 70.5, "comparative_hot_water_efficiency_pct": 38.1, "output_kw_max": 27.8, "final_year_of_manufacture": null, "raw": ["008815", "000214", "0", "2024/Jan/31 10:17", "Finterm SpA", "Lamborghini", "ALBA", "24 ASB", "9879025847", "2002", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "27.8", "27.8", "", "", "79.6", "70.5", "", "38.1", "", "2", "", "", "106", "1", "2", "153", "", "1", "1", "0", "67.5", "0", "30", "1", "60", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.3", "78.7", "", "", "", "", "79.4"]} -{"pcdb_id": 8816, "brand_name": "Lamborghini", "model_name": "ALBA", "model_qualifier": "20 ASB", "winter_efficiency_pct": 80.5, "summer_efficiency_pct": 71.4, "comparative_hot_water_efficiency_pct": 38.6, "output_kw_max": 23.9, "final_year_of_manufacture": null, "raw": ["008816", "000214", "0", "2024/Jan/31 10:17", "Finterm SpA", "Lamborghini", "ALBA", "20 ASB", "9879020847", "2002", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "23.9", "23.9", "", "", "80.5", "71.4", "", "38.6", "", "2", "", "", "106", "1", "2", "150", "", "1", "1", "0", "67.5", "0", "30", "1", "60", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.9", "79.9", "", "", "", "", "80.5"]} -{"pcdb_id": 8817, "brand_name": "Lamborghini", "model_name": "ALBA", "model_qualifier": "24 AS", "winter_efficiency_pct": 79.8, "summer_efficiency_pct": 69.7, "comparative_hot_water_efficiency_pct": 49.0, "output_kw_max": 27.48, "final_year_of_manufacture": null, "raw": ["008817", "000214", "0", "2006/Jan/17 12:31", "Finterm SpA", "Lamborghini", "ALBA", "24 AS", "9879025447", "2001", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "27.48", "27.48", "", "", "79.8", "69.7", "", "49.0", "", "2", "", "", "104", "1", "2", "175", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.0", "80.1", "", "", "", "", "80.5"]} -{"pcdb_id": 8818, "brand_name": "Lamborghini", "model_name": "ALBA", "model_qualifier": "20 AS", "winter_efficiency_pct": 80.0, "summer_efficiency_pct": 69.9, "comparative_hot_water_efficiency_pct": 49.2, "output_kw_max": 23.7, "final_year_of_manufacture": null, "raw": ["008818", "000214", "0", "2006/Jan/17 12:31", "Finterm SpA", "Lamborghini", "ALBA", "20 AS", "9879020447", "2002", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "23.7", "23.7", "", "", "80.0", "69.9", "", "49.2", "", "2", "", "", "104", "1", "2", "175", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.3", "80.2", "", "", "", "", "80.6"]} -{"pcdb_id": 8819, "brand_name": "Lamborghini", "model_name": "ALBA", "model_qualifier": "20 BS", "winter_efficiency_pct": 77.5, "summer_efficiency_pct": 67.4, "comparative_hot_water_efficiency_pct": 47.4, "output_kw_max": 22.75, "final_year_of_manufacture": null, "raw": ["008819", "000214", "0", "2006/Jan/17 12:31", "Finterm SpA", "Lamborghini", "ALBA", "20 BS", "9878020447", "2002", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "22.75", "22.75", "", "", "77.5", "67.4", "", "47.4", "", "2", "", "", "104", "1", "2", "175", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.0", "75.3", "", "", "", "", "76.6"]} -{"pcdb_id": 8820, "brand_name": "Lamborghini", "model_name": "ALBA", "model_qualifier": "24 RS", "winter_efficiency_pct": 80.0, "summer_efficiency_pct": 69.3, "comparative_hot_water_efficiency_pct": 50.7, "output_kw_max": 27.48, "final_year_of_manufacture": null, "raw": ["008820", "000214", "0", "2012/Mar/27 10:12", "Finterm SpA", "Lamborghini", "ALBA", "24 RS", "9879025247", "2002", "current", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "27.48", "27.48", "", "", "80.0", "69.3", "", "50.7", "", "2", "", "", "102", "1", "2", "175", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.0", "80.1", "", "", "", "", "80.5"]} -{"pcdb_id": 8827, "brand_name": "Glow-worm", "model_name": "24ci", "model_qualifier": "", "winter_efficiency_pct": 79.2, "summer_efficiency_pct": 69.1, "comparative_hot_water_efficiency_pct": 48.6, "output_kw_max": 23.6, "final_year_of_manufacture": null, "raw": ["008827", "000207", "0", "2006/Jan/17 12:31", "Hepworth Heating", "Glow-worm", "24ci", "", "GC 47-047-19", "2001", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "23.6", "23.6", "", "", "79.2", "69.1", "", "48.6", "", "2", "", "", "104", "1", "2", "122", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.4", "79.5", "", "", "", "", "79.8"]} -{"pcdb_id": 8828, "brand_name": "Saunier Duval", "model_name": "Thema Classic F24E", "model_qualifier": "", "winter_efficiency_pct": 79.2, "summer_efficiency_pct": 69.1, "comparative_hot_water_efficiency_pct": 48.6, "output_kw_max": 23.6, "final_year_of_manufacture": null, "raw": ["008828", "000206", "0", "2006/Jan/17 12:31", "Hepworth Heating", "Saunier Duval", "Thema Classic F24E", "", "GC 47-920-35", "2001", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "23.6", "23.6", "", "", "79.2", "69.1", "", "48.6", "", "2", "", "", "104", "1", "2", "122", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.4", "79.5", "", "", "", "", "79.8"]} -{"pcdb_id": 8829, "brand_name": "Glow-worm", "model_name": "Xtrafast 120", "model_qualifier": "", "winter_efficiency_pct": 79.5, "summer_efficiency_pct": 69.4, "comparative_hot_water_efficiency_pct": 48.8, "output_kw_max": 34.6, "final_year_of_manufacture": null, "raw": ["008829", "000207", "0", "2006/Jan/17 12:31", "Saunier Duval", "Glow-worm", "Xtrafast 120", "", "GC 47-920-18", "2000", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "34.6", "34.6", "", "", "79.5", "69.4", "", "48.8", "", "2", "", "", "104", "1", "2", "220", "50", "0", "", "", "0", "0", "0", "", "0", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "83.2", "78.5", "", "", "", "", "79.4"]} -{"pcdb_id": 8830, "brand_name": "Glow-worm", "model_name": "Xtrafast 96", "model_qualifier": "", "winter_efficiency_pct": 80.3, "summer_efficiency_pct": 70.2, "comparative_hot_water_efficiency_pct": 49.4, "output_kw_max": 27.6, "final_year_of_manufacture": null, "raw": ["008830", "000207", "0", "2006/Jan/17 12:31", "Saunier Duval", "Glow-worm", "Xtrafast 96", "", "GC 47-920-15", "2000", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "27.6", "27.6", "", "", "80.3", "70.2", "", "49.4", "", "2", "", "", "104", "1", "2", "220", "50", "0", "", "", "0", "0", "0", "", "0", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.4", "80.6", "", "", "", "", "81.0"]} -{"pcdb_id": 8831, "brand_name": "Saunier Duval", "model_name": "Isofast F35E", "model_qualifier": "", "winter_efficiency_pct": 79.5, "summer_efficiency_pct": 69.4, "comparative_hot_water_efficiency_pct": 48.8, "output_kw_max": 34.6, "final_year_of_manufacture": null, "raw": ["008831", "000206", "0", "2012/Mar/26 14:28", "Saunier Duval", "Saunier Duval", "Isofast F35E", "", "GC 47-920-18", "2000", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "34.6", "34.6", "", "", "79.5", "69.4", "", "48.8", "", "2", "", "", "104", "1", "2", "220", "50", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "2", "0", "50", "0004", "", "", "", "", "", "", "", "", "83.2", "78.5", "", "", "", "", "79.4"]} -{"pcdb_id": 8832, "brand_name": "Saunier Duval", "model_name": "Isofast F28E", "model_qualifier": "", "winter_efficiency_pct": 80.3, "summer_efficiency_pct": 70.2, "comparative_hot_water_efficiency_pct": 49.4, "output_kw_max": 27.6, "final_year_of_manufacture": null, "raw": ["008832", "000206", "0", "2012/Apr/03 11:16", "Saunier Duval", "Saunier Duval", "Isofast F28E", "", "GC 47-920-15", "2000", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "27.6", "27.6", "", "", "80.3", "70.2", "", "49.4", "", "2", "", "", "104", "1", "2", "220", "50", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "2", "0", "50", "0004", "", "", "", "", "", "", "", "", "82.4", "80.6", "", "", "", "", "81.0"]} -{"pcdb_id": 8833, "brand_name": "Worcester", "model_name": "Highflow 400 Electronic RSF", "model_qualifier": "RSF", "winter_efficiency_pct": 81.1, "summer_efficiency_pct": 72.0, "comparative_hot_water_efficiency_pct": 37.1, "output_kw_max": 24.0, "final_year_of_manufacture": 2005, "raw": ["008833", "000035", "0", "2024/Jan/31 10:17", "Worcester Heat Systems", "Worcester", "Highflow 400 Electronic RSF", "RSF", "47 311 64", "2002", "2005", "2", "1", "1", "2", "0", "", "", "1", "2", "2", "24", "24", "", "", "81.1", "72.0", "", "37.1", "", "2", "0", "", "106", "1", "2", "", "", "1", "1", "0", "65", "0", "25", "3", "75", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "84.1", "79.9", "", "", "", "", "80.7"]} -{"pcdb_id": 8834, "brand_name": "Worcester", "model_name": "Highflow 400 Electronic RSF", "model_qualifier": "RSF", "winter_efficiency_pct": 79.6, "summer_efficiency_pct": 70.5, "comparative_hot_water_efficiency_pct": 36.3, "output_kw_max": 24.0, "final_year_of_manufacture": 2005, "raw": ["008834", "000035", "0", "2024/Jan/31 10:17", "Worcester Heat Systems", "Worcester", "Highflow 400 Electronic RSF", "RSF", "47 311 61", "2002", "2005", "1", "1", "1", "2", "0", "", "", "1", "2", "2", "24", "24", "", "", "79.6", "70.5", "", "36.3", "", "2", "", "", "106", "1", "2", "", "", "1", "1", "0", "65", "0", "25", "3", "75", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.2", "78.9", "", "", "", "", "79.5"]} -{"pcdb_id": 8835, "brand_name": "Worcester", "model_name": "Highflow 400 Electronic BF", "model_qualifier": "BF", "winter_efficiency_pct": 80.8, "summer_efficiency_pct": 71.7, "comparative_hot_water_efficiency_pct": 36.9, "output_kw_max": 24.0, "final_year_of_manufacture": 2005, "raw": ["008835", "000035", "0", "2024/Jan/31 10:17", "Worcester Heat Systems", "Worcester", "Highflow 400 Electronic BF", "BF", "47 311 62", "2002", "2005", "1", "1", "1", "2", "0", "", "", "1", "2", "1", "24", "24", "", "", "80.8", "71.7", "", "36.9", "", "2", "", "", "106", "1", "2", "", "", "1", "1", "0", "65", "0", "25", "3", "75", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.8", "80.5", "", "", "", "", "81.0"]} -{"pcdb_id": 8836, "brand_name": "Worcester", "model_name": "Highflow 400 Electronic OF", "model_qualifier": "OF", "winter_efficiency_pct": 79.3, "summer_efficiency_pct": 70.2, "comparative_hot_water_efficiency_pct": 36.1, "output_kw_max": 24.0, "final_year_of_manufacture": 2005, "raw": ["008836", "000035", "0", "2024/Jan/31 10:17", "Worcester Heat Systems", "Worcester", "Highflow 400 Electronic OF", "OF", "47 311 63", "2002", "2005", "1", "1", "1", "2", "0", "", "", "1", "1", "1", "24", "24", "", "", "79.3", "70.2", "", "36.1", "", "2", "", "", "106", "1", "2", "", "", "1", "1", "0", "65", "0", "25", "3", "75", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.4", "79.0", "", "", "", "", "79.5"]} -{"pcdb_id": 8843, "brand_name": "HRM Boilers", "model_name": "Wallstar 20/25", "model_qualifier": "13", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 25.0, "final_year_of_manufacture": null, "raw": ["008843", "000098", "0", "2012/Mar/27 10:12", "HRM Boilers", "HRM Boilers", "Wallstar 20/25", "13", "10021218", "2002", "current", "4", "2", "1", "1", "0", "", "", "1", "2", "2", "20", "25", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "140", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.3", "87.5", "", "", "", "", "87.3"]} -{"pcdb_id": 8844, "brand_name": "Ariston", "model_name": "Genus 27 BFFI Plus", "model_qualifier": "Mk2", "winter_efficiency_pct": 80.8, "summer_efficiency_pct": 71.7, "comparative_hot_water_efficiency_pct": 38.0, "output_kw_max": 27.4, "final_year_of_manufacture": 2007, "raw": ["008844", "000080", "0", "2024/Jan/31 10:17", "Merloni TermoSanitari SpA", "Ariston", "Genus 27 BFFI Plus", "Mk2", "GC No. 47-116-11", "2002", "2007", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "27.4", "27.4", "", "", "80.8", "71.7", "", "38.0", "", "2", "", "", "106", "1", "2", "200", "7", "2", "2", "0", "52", "0", "15", "2", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "83.0", "80.0", "", "", "", "", "80.6"]} -{"pcdb_id": 8845, "brand_name": "Ariston", "model_name": "Ecogenus 24 RFFI System", "model_qualifier": "Mk2", "winter_efficiency_pct": 87.6, "summer_efficiency_pct": 78.6, "comparative_hot_water_efficiency_pct": 57.4, "output_kw_max": 24.5, "final_year_of_manufacture": 2003, "raw": ["008845", "000080", "0", "2012/Mar/27 10:12", "Merloni TermoSanitari SpA", "Ariston", "Ecogenus 24 RFFI System", "Mk2", "GC No. 41-116-03", "2002", "2003", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24.5", "24.5", "", "", "87.6", "78.6", "", "57.4", "", "2", "", "", "102", "1", "2", "130", "7", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.7", "95.9", "", "", "", "", "94.3"]} -{"pcdb_id": 8846, "brand_name": "Ariston", "model_name": "Ecogenus 24 MFFI", "model_qualifier": "Mk2", "winter_efficiency_pct": 87.6, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 55.5, "output_kw_max": 24.5, "final_year_of_manufacture": 2003, "raw": ["008846", "000080", "0", "2006/Jan/17 12:55", "Merloni TermoSanitari SpA", "Ariston", "Ecogenus 24 MFFI", "Mk2", "GC No. 47-116-17", "2002", "2003", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.5", "24.5", "", "", "87.6", "79.0", "", "55.5", "", "2", "", "", "104", "1", "2", "130", "5", "0", "1", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.7", "95.9", "", "", "", "", "94.3"]} -{"pcdb_id": 8847, "brand_name": "Halstead", "model_name": "Finest", "model_qualifier": "fpx", "winter_efficiency_pct": 82.0, "summer_efficiency_pct": 71.9, "comparative_hot_water_efficiency_pct": 50.5, "output_kw_max": 26.4, "final_year_of_manufacture": 2006, "raw": ["008847", "000019", "0", "2008/Feb/19 10:12", "Halstead Boilers", "Halstead", "Finest", "fpx", "", "2002", "2006", "2", "2", "1", "2", "0", "", "", "1", "2", "2", "26.4", "26.4", "", "", "82.0", "71.9", "", "50.5", "", "2", "1", "", "104", "1", "2", "150", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "83.3", "83.1", "", "", "", "", "83.1"]} -{"pcdb_id": 8848, "brand_name": "Halstead", "model_name": "Best 40 P", "model_qualifier": "", "winter_efficiency_pct": 81.3, "summer_efficiency_pct": 71.2, "comparative_hot_water_efficiency_pct": 52.0, "output_kw_max": 13.4, "final_year_of_manufacture": 2006, "raw": ["008848", "000019", "0", "2012/Mar/27 10:12", "Halstead Boilers", "Halstead", "Best 40 P", "", "DBPX40", "2002", "2006", "2", "2", "1", "1", "0", "", "", "1", "2", "2", "0", "13.4", "", "", "81.3", "71.2", "", "52.0", "", "2", "1", "", "101", "1", "1", "45", "5", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "83.1", "82.8", "", "", "", "", "82.9"]} -{"pcdb_id": 8849, "brand_name": "Halstead", "model_name": "Best 60 P", "model_qualifier": "", "winter_efficiency_pct": 81.9, "summer_efficiency_pct": 71.8, "comparative_hot_water_efficiency_pct": 52.4, "output_kw_max": 19.8, "final_year_of_manufacture": 2006, "raw": ["008849", "000019", "0", "2012/Mar/27 10:12", "Halstead Boilers", "Halstead", "Best 60 P", "", "DBPX60", "2002", "2006", "2", "2", "1", "1", "0", "", "", "1", "2", "2", "0", "19.8", "", "", "81.9", "71.8", "", "52.4", "", "2", "1", "", "101", "1", "1", "45", "5", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "83.4", "83.6", "", "", "", "", "83.6"]} -{"pcdb_id": 8850, "brand_name": "Worcester", "model_name": "Danesmoor", "model_qualifier": "20/25-000-GB-L", "winter_efficiency_pct": 85.3, "summer_efficiency_pct": 73.6, "comparative_hot_water_efficiency_pct": 53.7, "output_kw_max": 25.0, "final_year_of_manufacture": 2008, "raw": ["008850", "000035", "0", "2020/Sep/04 07:57", "Worcester Heat Systems", "Worcester", "Danesmoor", "20/25-000-GB-L", "C16395/1", "2001", "2008", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "20", "25", "", "", "85.3", "73.6", "", "53.7", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.3", "85.3", "", "", "", "", "85.3"]} -{"pcdb_id": 8851, "brand_name": "Worcester", "model_name": "Danesmoor", "model_qualifier": "20/25 - R00-GB-L", "winter_efficiency_pct": 85.3, "summer_efficiency_pct": 73.6, "comparative_hot_water_efficiency_pct": 53.7, "output_kw_max": 25.0, "final_year_of_manufacture": 2008, "raw": ["008851", "000035", "0", "2020/Sep/04 07:57", "Worcester Heat Systems", "Worcester", "Danesmoor", "20/25 - R00-GB-L", "C16395/1", "2001", "2008", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "20", "25", "", "", "85.3", "73.6", "", "53.7", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.3", "85.3", "", "", "", "", "85.3"]} -{"pcdb_id": 8852, "brand_name": "Worcester", "model_name": "Danesmoor Utility", "model_qualifier": "20/25-000-GB-L Utility", "winter_efficiency_pct": 85.3, "summer_efficiency_pct": 73.6, "comparative_hot_water_efficiency_pct": 53.7, "output_kw_max": 25.0, "final_year_of_manufacture": 2008, "raw": ["008852", "000035", "0", "2020/Sep/04 07:57", "Worcester Heat Systems", "Worcester", "Danesmoor Utility", "20/25-000-GB-L Utility", "C16395/1", "2001", "2008", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "20", "25", "", "", "85.3", "73.6", "", "53.7", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.3", "85.3", "", "", "", "", "85.3"]} -{"pcdb_id": 8853, "brand_name": "Worcester", "model_name": "Danesmoor Utility", "model_qualifier": "20/25-R00-GB-L Utility", "winter_efficiency_pct": 85.3, "summer_efficiency_pct": 73.6, "comparative_hot_water_efficiency_pct": 53.7, "output_kw_max": 25.0, "final_year_of_manufacture": 2008, "raw": ["008853", "000035", "0", "2020/Sep/04 07:58", "Worcester Heat Systems", "Worcester", "Danesmoor Utility", "20/25-R00-GB-L Utility", "C16395/1", "2001", "2008", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "20", "25", "", "", "85.3", "73.6", "", "53.7", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.3", "85.3", "", "", "", "", "85.3"]} -{"pcdb_id": 8854, "brand_name": "Worcester", "model_name": "Danesmoor System", "model_qualifier": "20/25-0S0-GB-L System", "winter_efficiency_pct": 85.3, "summer_efficiency_pct": 73.6, "comparative_hot_water_efficiency_pct": 53.7, "output_kw_max": 25.0, "final_year_of_manufacture": 2008, "raw": ["008854", "000035", "0", "2020/Sep/04 07:58", "Worcester Heat Systems", "Worcester", "Danesmoor System", "20/25-0S0-GB-L System", "C16395/1", "2001", "2008", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "20", "25", "", "", "85.3", "73.6", "", "53.7", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.3", "85.3", "", "", "", "", "85.3"]} -{"pcdb_id": 8855, "brand_name": "Worcester", "model_name": "Danesmoor System", "model_qualifier": "20/25-RS0-GB-L System", "winter_efficiency_pct": 85.3, "summer_efficiency_pct": 73.6, "comparative_hot_water_efficiency_pct": 53.7, "output_kw_max": 25.0, "final_year_of_manufacture": 2008, "raw": ["008855", "000035", "0", "2020/Sep/04 07:58", "Worcester Heat Systems", "Worcester", "Danesmoor System", "20/25-RS0-GB-L System", "C16395/1", "2001", "2008", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "20", "25", "", "", "85.3", "73.6", "", "53.7", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.3", "85.3", "", "", "", "", "85.3"]} -{"pcdb_id": 8856, "brand_name": "Worcester", "model_name": "Bosch", "model_qualifier": "70/90-000-NI-L", "winter_efficiency_pct": 85.3, "summer_efficiency_pct": 73.6, "comparative_hot_water_efficiency_pct": 53.7, "output_kw_max": 25.0, "final_year_of_manufacture": 2008, "raw": ["008856", "000035", "0", "2020/Sep/04 07:58", "Worcester Heat Systems", "Worcester", "Bosch", "70/90-000-NI-L", "C16395/1", "2001", "2008", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "20", "25", "", "", "85.3", "73.6", "", "53.7", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.3", "85.3", "", "", "", "", "85.3"]} -{"pcdb_id": 8857, "brand_name": "Worcester", "model_name": "Danesmoor", "model_qualifier": "12/14-000-GB-L", "winter_efficiency_pct": 85.5, "summer_efficiency_pct": 73.8, "comparative_hot_water_efficiency_pct": 53.9, "output_kw_max": 14.0, "final_year_of_manufacture": 2008, "raw": ["008857", "000035", "0", "2020/Sep/04 07:58", "Worcester Heat Systems", "Worcester", "Danesmoor", "12/14-000-GB-L", "C16394/1", "2001", "2008", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "12", "14", "", "", "85.5", "73.8", "", "53.9", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.4", "85.5", "", "", "", "", "85.5"]} -{"pcdb_id": 8858, "brand_name": "Worcester", "model_name": "Danesmoor", "model_qualifier": "12/14-R00-GB-L", "winter_efficiency_pct": 85.5, "summer_efficiency_pct": 73.8, "comparative_hot_water_efficiency_pct": 53.9, "output_kw_max": 14.0, "final_year_of_manufacture": 2008, "raw": ["008858", "000035", "0", "2020/Sep/04 07:58", "Worcester Heat Systems", "Worcester", "Danesmoor", "12/14-R00-GB-L", "C16394/1", "2001", "2008", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "12", "14", "", "", "85.5", "73.8", "", "53.9", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.4", "85.5", "", "", "", "", "85.5"]} -{"pcdb_id": 8859, "brand_name": "Worcester", "model_name": "Danesmoor Utility", "model_qualifier": "12/14-000-GB-L Utility", "winter_efficiency_pct": 85.5, "summer_efficiency_pct": 73.8, "comparative_hot_water_efficiency_pct": 53.9, "output_kw_max": 14.0, "final_year_of_manufacture": 2008, "raw": ["008859", "000035", "0", "2020/Sep/04 07:59", "Worcester Heat Systems", "Worcester", "Danesmoor Utility", "12/14-000-GB-L Utility", "C16394/1", "2001", "2008", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "12", "14", "", "", "85.5", "73.8", "", "53.9", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.4", "85.5", "", "", "", "", "85.5"]} -{"pcdb_id": 8860, "brand_name": "Worcester", "model_name": "Danesmoor Utility", "model_qualifier": "12/14-R00-GB-L Utility", "winter_efficiency_pct": 85.5, "summer_efficiency_pct": 73.8, "comparative_hot_water_efficiency_pct": 53.9, "output_kw_max": 14.0, "final_year_of_manufacture": 2008, "raw": ["008860", "000035", "0", "2020/Sep/04 07:59", "Worcester Heat Systems", "Worcester", "Danesmoor Utility", "12/14-R00-GB-L Utility", "C16394/1", "2001", "2008", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "12", "14", "", "", "85.5", "73.8", "", "53.9", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.4", "85.5", "", "", "", "", "85.5"]} -{"pcdb_id": 8861, "brand_name": "Worcester", "model_name": "Danesmoor System", "model_qualifier": "12/14-0S0-GB-L System", "winter_efficiency_pct": 85.5, "summer_efficiency_pct": 73.8, "comparative_hot_water_efficiency_pct": 53.9, "output_kw_max": 14.0, "final_year_of_manufacture": 2008, "raw": ["008861", "000035", "0", "2020/Sep/04 07:59", "Worcester Heat Systems", "Worcester", "Danesmoor System", "12/14-0S0-GB-L System", "C16394/1", "2001", "2008", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "12", "14", "", "", "85.5", "73.8", "", "53.9", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.4", "85.5", "", "", "", "", "85.5"]} -{"pcdb_id": 8862, "brand_name": "Worcester", "model_name": "Danesmoor System", "model_qualifier": "12/14-RS0-GB-L System", "winter_efficiency_pct": 85.5, "summer_efficiency_pct": 73.8, "comparative_hot_water_efficiency_pct": 53.9, "output_kw_max": 14.0, "final_year_of_manufacture": 2008, "raw": ["008862", "000035", "0", "2020/Sep/04 07:59", "Worcester Heat Systems", "Worcester", "Danesmoor System", "12/14-RS0-GB-L System", "C16394/1", "2001", "2008", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "12", "14", "", "", "85.5", "73.8", "", "53.9", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.4", "85.5", "", "", "", "", "85.5"]} -{"pcdb_id": 8863, "brand_name": "Radiant", "model_name": "RBS 20 E", "model_qualifier": "Midy", "winter_efficiency_pct": 80.5, "summer_efficiency_pct": 70.4, "comparative_hot_water_efficiency_pct": 49.5, "output_kw_max": 26.6, "final_year_of_manufacture": null, "raw": ["008863", "000088", "0", "2008/Feb/19 10:31", "Radiant Bruciatori SpA", "Radiant", "RBS 20 E", "Midy", "", "2002", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "26.60", "26.60", "", "", "80.5", "70.4", "", "49.5", "", "2", "", "", "104", "1", "2", "170", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "83.6", "80.5", "", "", "", "", "81.1"]} -{"pcdb_id": 8864, "brand_name": "Radiant", "model_name": "RS 24 E", "model_qualifier": "Midy", "winter_efficiency_pct": 80.4, "summer_efficiency_pct": 69.7, "comparative_hot_water_efficiency_pct": 50.9, "output_kw_max": 29.8, "final_year_of_manufacture": null, "raw": ["008864", "000088", "0", "2012/Mar/27 10:12", "Radiant Bruciatori SpA", "Radiant", "RS 24 E", "Midy", "", "2002", "current", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "29.80", "29.80", "", "", "80.4", "69.7", "", "50.9", "", "2", "", "", "102", "1", "2", "170", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.5", "80.3", "", "", "", "", "80.7"]} -{"pcdb_id": 8865, "brand_name": "Radiant", "model_name": "RSF 24 E", "model_qualifier": "Slim", "winter_efficiency_pct": 80.2, "summer_efficiency_pct": 70.1, "comparative_hot_water_efficiency_pct": 49.3, "output_kw_max": 29.8, "final_year_of_manufacture": null, "raw": ["008865", "000088", "0", "2008/Feb/19 10:33", "Radiant Bruciatori SpA", "Radiant", "RSF 24 E", "Slim", "", "2002", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "29.80", "29.80", "", "", "80.2", "70.1", "", "49.3", "", "2", "", "", "104", "1", "2", "170", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.5", "80.3", "", "", "", "", "80.7"]} -{"pcdb_id": 8866, "brand_name": "Baxi Potterton", "model_name": "Potterton Promax", "model_qualifier": "24 HE", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 22.0, "final_year_of_manufacture": 2005, "raw": ["008866", "000005", "0", "2012/Mar/27 10:12", "Baxi Potterton", "Baxi Potterton", "Potterton Promax", "24 HE", "GC No. 41-590-62", "2002", "2005", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "22.0", "22.0", "", "", "88.8", "79.8", "", "58.3", "", "2", "", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.5", "98.1", "", "", "", "", "96.5"]} -{"pcdb_id": 8867, "brand_name": "Baxi Potterton", "model_name": "Potterton Promax", "model_qualifier": "15 HE", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 15.24, "final_year_of_manufacture": 2005, "raw": ["008867", "000005", "0", "2012/Mar/27 10:12", "Baxi Potterton", "Baxi Potterton", "Potterton Promax", "15 HE", "GC No. 41-590-58", "2002", "2005", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "15.24", "15.24", "", "", "88.7", "79.7", "", "58.2", "", "2", "", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.3", "97.7", "", "", "", "", "96.3"]} -{"pcdb_id": 8868, "brand_name": "Baxi", "model_name": "100 HE", "model_qualifier": "", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 30.18, "final_year_of_manufacture": 2004, "raw": ["008868", "000005", "0", "2012/Mar/27 10:12", "Baxi Potterton", "Baxi", "100 HE", "", "GC No. 47-590-62", "2002", "2004", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "30.18", "30.18", "", "", "88.9", "79.9", "", "58.4", "", "2", "", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.4", "98.5", "", "", "", "", "96.8"]} -{"pcdb_id": 8869, "brand_name": "Baxi", "model_name": "Solo 3 PFL System", "model_qualifier": "80", "winter_efficiency_pct": 79.6, "summer_efficiency_pct": 69.5, "comparative_hot_water_efficiency_pct": 50.8, "output_kw_max": 23.44, "final_year_of_manufacture": 2006, "raw": ["008869", "000005", "0", "2012/Mar/27 10:12", "Baxi Potterton", "Baxi", "Solo 3 PFL System", "80", "GC No. 41-075-31", "2001", "2006", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "23.44", "23.44", "", "", "79.6", "69.5", "", "50.8", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.4", "81.1", "", "", "", "", "81.1"]} -{"pcdb_id": 8870, "brand_name": "Baxi", "model_name": "Solo 3 PFL", "model_qualifier": "80", "winter_efficiency_pct": 80.0, "summer_efficiency_pct": 69.9, "comparative_hot_water_efficiency_pct": 51.0, "output_kw_max": 23.44, "final_year_of_manufacture": 2010, "raw": ["008870", "000005", "0", "2012/Mar/27 10:12", "Baxi Potterton", "Baxi", "Solo 3 PFL", "80", "GC No. 41-075-30", "2001", "2010", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "23.44", "23.44", "", "", "80.0", "69.9", "", "51.0", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.4", "81.8", "", "", "", "", "81.7"]} -{"pcdb_id": 8871, "brand_name": "Baxi Potterton", "model_name": "Baxi Combi", "model_qualifier": "130 HE", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 55.9, "output_kw_max": 30.0, "final_year_of_manufacture": 2004, "raw": ["008871", "000005", "0", "2009/Oct/26 16:56", "Baxi Potterton", "Baxi Potterton", "Baxi Combi", "130 HE", "GC No. 47-590-04", "2002", "2004", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "30.00", "30.00", "", "", "88.1", "79.5", "", "55.9", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.2", "96.6", "", "", "", "", "95.2"]} -{"pcdb_id": 8872, "brand_name": "Glow-worm", "model_name": "18hxi", "model_qualifier": "", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 78.9, "comparative_hot_water_efficiency_pct": 57.6, "output_kw_max": 18.57, "final_year_of_manufacture": null, "raw": ["008872", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "18hxi", "", "GC 41-047-63", "2002", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18.57", "18.57", "", "", "87.9", "78.9", "", "57.6", "", "2", "", "", "102", "1", "2", "60", "15", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.6", "96.3", "", "", "", "", "94.8"]} -{"pcdb_id": 8873, "brand_name": "Glow-worm", "model_name": "30hxi", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 28.17, "final_year_of_manufacture": null, "raw": ["008873", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "30hxi", "", "GC 41-047-64", "2002", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "28.17", "28.17", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "60", "15", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.7", "96.4", "", "", "", "", "95.0"]} -{"pcdb_id": 8874, "brand_name": "Glow-worm", "model_name": "30sxi", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 28.17, "final_year_of_manufacture": null, "raw": ["008874", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "30sxi", "", "GC 47-047-62", "2002", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "28.17", "28.17", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "180", "15", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.7", "96.4", "", "", "", "", "95.0"]} -{"pcdb_id": 8875, "brand_name": "Glow-worm", "model_name": "30cxi", "model_qualifier": "", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 55.8, "output_kw_max": 22.94, "final_year_of_manufacture": null, "raw": ["008875", "000207", "0", "2006/Jan/17 12:31", "Hepworth Heating", "Glow-worm", "30cxi", "", "GC 47-047-24", "2002", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "22.94", "22.94", "", "", "87.9", "79.3", "", "55.8", "", "2", "", "", "104", "1", "2", "180", "15", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "96.4", "", "", "", "", "94.9"]} -{"pcdb_id": 8876, "brand_name": "Glow-worm", "model_name": "24cxi", "model_qualifier": "", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 55.8, "output_kw_max": 18.0, "final_year_of_manufacture": null, "raw": ["008876", "000207", "0", "2006/Jan/17 12:31", "Hepworth Heating", "Glow-worm", "24cxi", "", "GC 47-047-23", "2002", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "18", "18", "", "", "87.9", "79.3", "", "55.8", "", "2", "", "", "104", "1", "2", "180", "15", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.6", "96.3", "", "", "", "", "94.8"]} -{"pcdb_id": 8877, "brand_name": "Glow-worm", "model_name": "BBU 54/4", "model_qualifier": "Miami 4", "winter_efficiency_pct": 79.7, "summer_efficiency_pct": 69.6, "comparative_hot_water_efficiency_pct": 50.8, "output_kw_max": 15.83, "final_year_of_manufacture": null, "raw": ["008877", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "BBU 54/4", "Miami 4", "44 047 05", "2001", "current", "1", "4", "1", "1", "0", "", "", "1", "1", "1", "13.19", "15.83", "", "", "79.7", "69.6", "", "50.8", "", "2", "", "", "101", "1", "1", "8", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "80.9", "81.6", "", "", "", "", "81.5"]} -{"pcdb_id": 8878, "brand_name": "Glow-worm", "model_name": "BBU 54/4", "model_qualifier": "Firelite 4", "winter_efficiency_pct": 79.7, "summer_efficiency_pct": 69.6, "comparative_hot_water_efficiency_pct": 50.8, "output_kw_max": 15.83, "final_year_of_manufacture": null, "raw": ["008878", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "BBU 54/4", "Firelite 4", "44 047 05", "2001", "current", "1", "4", "1", "1", "0", "", "", "1", "1", "1", "13.19", "15.83", "", "", "79.7", "69.6", "", "50.8", "", "2", "", "", "101", "1", "1", "8", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "80.9", "81.6", "", "", "", "", "81.5"]} -{"pcdb_id": 8879, "brand_name": "Glow-worm", "model_name": "BBU 54/4", "model_qualifier": "Contour 4", "winter_efficiency_pct": 79.7, "summer_efficiency_pct": 69.6, "comparative_hot_water_efficiency_pct": 50.8, "output_kw_max": 15.83, "final_year_of_manufacture": null, "raw": ["008879", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "BBU 54/4", "Contour 4", "44 047 05", "2001", "current", "1", "4", "1", "1", "0", "", "", "1", "1", "1", "13.19", "15.83", "", "", "79.7", "69.6", "", "50.8", "", "2", "", "", "101", "1", "1", "8", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "80.9", "81.6", "", "", "", "", "81.5"]} -{"pcdb_id": 8880, "brand_name": "Glow-worm", "model_name": "BBU 54/4", "model_qualifier": "Black Beauty 4", "winter_efficiency_pct": 79.7, "summer_efficiency_pct": 69.6, "comparative_hot_water_efficiency_pct": 50.8, "output_kw_max": 15.83, "final_year_of_manufacture": null, "raw": ["008880", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "BBU 54/4", "Black Beauty 4", "44 047 05", "2001", "current", "1", "4", "1", "1", "0", "", "", "1", "1", "1", "13.19", "15.83", "", "", "79.7", "69.6", "", "50.8", "", "2", "", "", "101", "1", "1", "8", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "80.9", "81.6", "", "", "", "", "81.5"]} -{"pcdb_id": 8881, "brand_name": "Glow-worm", "model_name": "BBU 54/4", "model_qualifier": "Heartbeat 4", "winter_efficiency_pct": 79.7, "summer_efficiency_pct": 69.6, "comparative_hot_water_efficiency_pct": 50.8, "output_kw_max": 15.83, "final_year_of_manufacture": null, "raw": ["008881", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "BBU 54/4", "Heartbeat 4", "44 047 05", "2001", "current", "1", "4", "1", "1", "0", "", "", "1", "1", "1", "13.19", "15.83", "", "", "79.7", "69.6", "", "50.8", "", "2", "", "", "101", "1", "1", "8", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "80.9", "81.6", "", "", "", "", "81.5"]} -{"pcdb_id": 8882, "brand_name": "Glow-worm", "model_name": "BBU 54/4", "model_qualifier": "Chatsworth 4", "winter_efficiency_pct": 80.3, "summer_efficiency_pct": 70.2, "comparative_hot_water_efficiency_pct": 51.3, "output_kw_max": 14.21, "final_year_of_manufacture": null, "raw": ["008882", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "BBU 54/4", "Chatsworth 4", "44 047 05", "2001", "current", "1", "4", "1", "1", "0", "", "", "1", "1", "1", "11.72", "14.21", "", "", "80.3", "70.2", "", "51.3", "", "2", "", "", "101", "1", "1", "8", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.9", "82.0", "", "", "", "", "82.0"]} -{"pcdb_id": 8883, "brand_name": "Glow-worm", "model_name": "BBU 54/4", "model_qualifier": "Dovedale 4", "winter_efficiency_pct": 80.3, "summer_efficiency_pct": 70.2, "comparative_hot_water_efficiency_pct": 51.3, "output_kw_max": 14.21, "final_year_of_manufacture": null, "raw": ["008883", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "BBU 54/4", "Dovedale 4", "44 047 05", "2001", "current", "1", "4", "1", "1", "0", "", "", "1", "1", "1", "11.72", "14.21", "", "", "80.3", "70.2", "", "51.3", "", "2", "", "", "101", "1", "1", "8", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.9", "82.0", "", "", "", "", "82.0"]} -{"pcdb_id": 8884, "brand_name": "Glow-worm", "model_name": "BBU 45/4", "model_qualifier": "Miami 4", "winter_efficiency_pct": 79.3, "summer_efficiency_pct": 69.2, "comparative_hot_water_efficiency_pct": 50.5, "output_kw_max": 13.19, "final_year_of_manufacture": null, "raw": ["008884", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "BBU 45/4", "Miami 4", "44 047 06", "2001", "current", "1", "4", "1", "1", "0", "", "", "1", "1", "1", "8.79", "13.19", "", "", "79.3", "69.2", "", "50.5", "", "2", "", "", "101", "1", "1", "8", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "80.8", "80.9", "", "", "", "", "80.9"]} -{"pcdb_id": 8885, "brand_name": "Glow-worm", "model_name": "BBU 45/4", "model_qualifier": "Firelite 4", "winter_efficiency_pct": 79.3, "summer_efficiency_pct": 69.2, "comparative_hot_water_efficiency_pct": 50.5, "output_kw_max": 13.19, "final_year_of_manufacture": null, "raw": ["008885", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "BBU 45/4", "Firelite 4", "44 047 06", "2001", "current", "1", "4", "1", "1", "0", "", "", "1", "1", "1", "8.79", "13.19", "", "", "79.3", "69.2", "", "50.5", "", "2", "", "", "101", "1", "1", "8", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "80.8", "80.9", "", "", "", "", "80.9"]} -{"pcdb_id": 8886, "brand_name": "Glow-worm", "model_name": "BBU 45/4", "model_qualifier": "Contour 4", "winter_efficiency_pct": 79.3, "summer_efficiency_pct": 69.2, "comparative_hot_water_efficiency_pct": 50.5, "output_kw_max": 13.19, "final_year_of_manufacture": null, "raw": ["008886", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "BBU 45/4", "Contour 4", "44 047 06", "2001", "current", "1", "4", "1", "1", "0", "", "", "1", "1", "1", "8.79", "13.19", "", "", "79.3", "69.2", "", "50.5", "", "2", "", "", "101", "1", "1", "8", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "80.8", "80.9", "", "", "", "", "80.9"]} -{"pcdb_id": 8887, "brand_name": "Glow-worm", "model_name": "BBU 45/4", "model_qualifier": "Black Beauty 4", "winter_efficiency_pct": 79.3, "summer_efficiency_pct": 69.2, "comparative_hot_water_efficiency_pct": 50.5, "output_kw_max": 13.19, "final_year_of_manufacture": null, "raw": ["008887", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "BBU 45/4", "Black Beauty 4", "44 047 06", "2001", "current", "1", "4", "1", "1", "0", "", "", "1", "1", "1", "8.79", "13.19", "", "", "79.3", "69.2", "", "50.5", "", "2", "", "", "101", "1", "1", "8", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "80.8", "80.9", "", "", "", "", "80.9"]} -{"pcdb_id": 8888, "brand_name": "Glow-worm", "model_name": "BBU 45/4", "model_qualifier": "Heartbeat 4", "winter_efficiency_pct": 79.3, "summer_efficiency_pct": 69.2, "comparative_hot_water_efficiency_pct": 50.5, "output_kw_max": 13.19, "final_year_of_manufacture": null, "raw": ["008888", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "BBU 45/4", "Heartbeat 4", "44 047 06", "2001", "current", "1", "4", "1", "1", "0", "", "", "1", "1", "1", "8.79", "13.19", "", "", "79.3", "69.2", "", "50.5", "", "2", "", "", "101", "1", "1", "8", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "80.8", "80.9", "", "", "", "", "80.9"]} -{"pcdb_id": 8889, "brand_name": "Glow-worm", "model_name": "BBU 45/4", "model_qualifier": "Chatsworth 4", "winter_efficiency_pct": 80.4, "summer_efficiency_pct": 70.3, "comparative_hot_water_efficiency_pct": 51.4, "output_kw_max": 11.72, "final_year_of_manufacture": null, "raw": ["008889", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "BBU 45/4", "Chatsworth 4", "44 047 06", "2001", "current", "1", "4", "1", "1", "0", "", "", "1", "1", "1", "8.79", "11.72", "", "", "80.4", "70.3", "", "51.4", "", "2", "", "", "101", "1", "1", "8", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.5", "81.5", "", "", "", "", "81.7"]} -{"pcdb_id": 8890, "brand_name": "Glow-worm", "model_name": "BBU 45/4", "model_qualifier": "Dovedale 4", "winter_efficiency_pct": 80.4, "summer_efficiency_pct": 70.3, "comparative_hot_water_efficiency_pct": 51.4, "output_kw_max": 11.72, "final_year_of_manufacture": null, "raw": ["008890", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "BBU 45/4", "Dovedale 4", "44 047 06", "2001", "current", "1", "4", "1", "1", "0", "", "", "1", "1", "1", "8.79", "11.72", "", "", "80.4", "70.3", "", "51.4", "", "2", "", "", "101", "1", "1", "8", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.5", "81.5", "", "", "", "", "81.7"]} -{"pcdb_id": 8891, "brand_name": "Worcester", "model_name": "Heatslave", "model_qualifier": "12/14-OSO-GB-L Oil Combi", "winter_efficiency_pct": 83.6, "summer_efficiency_pct": 75.5, "comparative_hot_water_efficiency_pct": 40.9, "output_kw_max": 14.0, "final_year_of_manufacture": 2008, "raw": ["008891", "000035", "0", "2024/Jan/31 10:17", "Worcester Heat Systems", "Worcester", "Heatslave", "12/14-OSO-GB-L Oil Combi", "C16394/1", "2001", "2008", "4", "1", "1", "2", "0", "", "", "1", "1", "2", "12", "14", "", "", "83.6", "75.5", "", "40.9", "", "2", "", "", "203", "1", "1", "", "", "1", "1", "0", "46", "0", "25", "3", "80", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.4", "85.5", "", "", "", "", "85.5"]} -{"pcdb_id": 8892, "brand_name": "Worcester", "model_name": "Heatslave", "model_qualifier": "12/14-RSO-GB-L Oil Combi", "winter_efficiency_pct": 83.6, "summer_efficiency_pct": 75.5, "comparative_hot_water_efficiency_pct": 40.9, "output_kw_max": 14.0, "final_year_of_manufacture": 2008, "raw": ["008892", "000035", "0", "2024/Jan/31 10:17", "Worcester Heat Systems", "Worcester", "Heatslave", "12/14-RSO-GB-L Oil Combi", "C16394/1", "2001", "2008", "4", "1", "1", "2", "0", "", "", "1", "2", "2", "12", "14", "", "", "83.6", "75.5", "", "40.9", "", "2", "", "", "203", "1", "1", "", "", "1", "1", "0", "46", "0", "25", "3", "80", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.4", "85.5", "", "", "", "", "85.5"]} -{"pcdb_id": 8893, "brand_name": "Worcester", "model_name": "Heatslave", "model_qualifier": "20/25-OSO-GB-L Oil Combi", "winter_efficiency_pct": 83.4, "summer_efficiency_pct": 75.3, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 25.0, "final_year_of_manufacture": 2008, "raw": ["008893", "000035", "0", "2024/Jan/31 10:17", "Worcester Heat Systems", "Worcester", "Heatslave", "20/25-OSO-GB-L Oil Combi", "C16395/1", "2001", "2008", "4", "1", "1", "2", "0", "", "", "1", "1", "2", "20", "25", "", "", "83.4", "75.3", "", "40.8", "", "2", "", "", "203", "1", "1", "", "", "1", "1", "0", "46", "0", "25", "3", "80", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.3", "85.3", "", "", "", "", "85.3"]} -{"pcdb_id": 8894, "brand_name": "Worcester", "model_name": "Heatslave", "model_qualifier": "20/25-RSO-GB-L Oil Combi", "winter_efficiency_pct": 83.4, "summer_efficiency_pct": 75.3, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 25.0, "final_year_of_manufacture": 2008, "raw": ["008894", "000035", "0", "2024/Jan/31 10:17", "Worcester Heat Systems", "Worcester", "Heatslave", "20/25-RSO-GB-L Oil Combi", "C16395/1", "2001", "2008", "4", "1", "1", "2", "0", "", "", "1", "2", "2", "20", "25", "", "", "83.4", "75.3", "", "40.8", "", "2", "", "", "203", "1", "1", "", "", "1", "1", "0", "46", "0", "25", "3", "80", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.3", "85.3", "", "", "", "", "85.3"]} -{"pcdb_id": 8895, "brand_name": "Worcester", "model_name": "Heatslave", "model_qualifier": "26/32-OSO-GB Oil Combi", "winter_efficiency_pct": 84.3, "summer_efficiency_pct": 76.2, "comparative_hot_water_efficiency_pct": 41.3, "output_kw_max": 32.0, "final_year_of_manufacture": 2008, "raw": ["008895", "000035", "0", "2024/Jan/31 10:17", "Worcester Heat Systems", "Worcester", "Heatslave", "26/32-OSO-GB Oil Combi", "C14769/5", "2001", "2008", "4", "1", "1", "2", "0", "", "", "1", "1", "2", "26", "32", "", "", "84.3", "76.2", "", "41.3", "", "2", "", "", "203", "1", "1", "", "", "1", "1", "0", "46", "0", "25", "3", "80", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.3", "88.1", "", "", "", "", "87.5"]} -{"pcdb_id": 8896, "brand_name": "Worcester", "model_name": "Heatslave", "model_qualifier": "26/32-RSO-GB Oil Combi", "winter_efficiency_pct": 84.3, "summer_efficiency_pct": 76.2, "comparative_hot_water_efficiency_pct": 41.3, "output_kw_max": 32.0, "final_year_of_manufacture": 2008, "raw": ["008896", "000035", "0", "2024/Jan/31 10:17", "Worcester Heat Systems", "Worcester", "Heatslave", "26/32-RSO-GB Oil Combi", "C14769/5", "2001", "2008", "4", "1", "1", "2", "0", "", "", "1", "2", "2", "26", "32", "", "", "84.3", "76.2", "", "41.3", "", "2", "", "", "203", "1", "1", "", "", "1", "1", "0", "46", "0", "25", "3", "80", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.3", "88.1", "", "", "", "", "87.5"]} -{"pcdb_id": 8897, "brand_name": "Ideal", "model_name": "Concord CXA", "model_qualifier": "40/H", "winter_efficiency_pct": 81.6, "summer_efficiency_pct": 71.5, "comparative_hot_water_efficiency_pct": 52.2, "output_kw_max": 43.5, "final_year_of_manufacture": null, "raw": ["008897", "000008", "0", "2012/Mar/27 10:12", "Ideal Boilers", "Ideal", "Concord CXA", "40/H", "PI No. 87AP80", "2001", "current", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "43.5", "43.5", "", "", "81.6", "71.5", "", "52.2", "", "2", "", "", "101", "1", "1", "5", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "83.7", "83.5", "", "", "", "", "83.6"]} -{"pcdb_id": 8898, "brand_name": "Ideal", "model_name": "Concord CXA", "model_qualifier": "50/H", "winter_efficiency_pct": 81.6, "summer_efficiency_pct": 71.5, "comparative_hot_water_efficiency_pct": 52.2, "output_kw_max": 54.3, "final_year_of_manufacture": null, "raw": ["008898", "000008", "0", "2012/Mar/27 10:12", "Ideal Boilers", "Ideal", "Concord CXA", "50/H", "PI No. 87AP80", "2001", "current", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "54.3", "54.3", "", "", "81.6", "71.5", "", "52.2", "", "2", "", "", "101", "1", "1", "5", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.7", "83.6", "", "", "", "", "83.4"]} -{"pcdb_id": 8899, "brand_name": "Ideal", "model_name": "Concord CXA", "model_qualifier": "60/H", "winter_efficiency_pct": 81.4, "summer_efficiency_pct": 71.3, "comparative_hot_water_efficiency_pct": 52.1, "output_kw_max": 65.2, "final_year_of_manufacture": null, "raw": ["008899", "000008", "0", "2012/Mar/27 10:12", "Ideal Boilers", "Ideal", "Concord CXA", "60/H", "PI No. 87AP80", "2001", "current", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "65.2", "65.2", "", "", "81.4", "71.3", "", "52.1", "", "2", "", "", "101", "1", "1", "5", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.6", "83.4", "", "", "", "", "83.3"]} -{"pcdb_id": 8906, "brand_name": "Ideal", "model_name": "Concord CXS", "model_qualifier": "40/H", "winter_efficiency_pct": 81.4, "summer_efficiency_pct": 70.7, "comparative_hot_water_efficiency_pct": 51.6, "output_kw_max": 43.5, "final_year_of_manufacture": null, "raw": ["008906", "000008", "0", "2012/Mar/27 10:12", "Ideal Boilers", "Ideal", "Concord CXS", "40/H", "PI No. 87AQ103", "2001", "current", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "43.5", "43.5", "", "", "81.4", "70.7", "", "51.6", "", "2", "", "", "102", "1", "2", "10", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "83.7", "81.9", "", "", "", "", "82.2"]} -{"pcdb_id": 8907, "brand_name": "Ideal", "model_name": "Concord CXS", "model_qualifier": "50/H", "winter_efficiency_pct": 81.1, "summer_efficiency_pct": 70.4, "comparative_hot_water_efficiency_pct": 51.4, "output_kw_max": 54.3, "final_year_of_manufacture": null, "raw": ["008907", "000008", "0", "2012/Mar/27 10:12", "Ideal Boilers", "Ideal", "Concord CXS", "50/H", "PI No. 87AQ103", "2001", "current", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "54.3", "54.3", "", "", "81.1", "70.4", "", "51.4", "", "2", "", "", "102", "1", "2", "10", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.7", "81.5", "", "", "", "", "81.8"]} -{"pcdb_id": 8908, "brand_name": "Ideal", "model_name": "Concord CXS", "model_qualifier": "60/H", "winter_efficiency_pct": 81.7, "summer_efficiency_pct": 71.0, "comparative_hot_water_efficiency_pct": 51.8, "output_kw_max": 65.2, "final_year_of_manufacture": null, "raw": ["008908", "000008", "0", "2012/Mar/27 10:12", "Ideal Boilers", "Ideal", "Concord CXS", "60/H", "PI No. 87AQ103", "2001", "current", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "65.2", "65.2", "", "", "81.7", "71.0", "", "51.8", "", "2", "", "", "102", "1", "2", "10", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.6", "82.7", "", "", "", "", "82.7"]} -{"pcdb_id": 8915, "brand_name": "Ideal", "model_name": "Concord CXSD", "model_qualifier": "40/H", "winter_efficiency_pct": 81.4, "summer_efficiency_pct": 70.7, "comparative_hot_water_efficiency_pct": 51.6, "output_kw_max": 43.5, "final_year_of_manufacture": null, "raw": ["008915", "000008", "0", "2012/Mar/27 10:12", "Ideal Boilers", "Ideal", "Concord CXSD", "40/H", "PI No. 87AQ103", "2001", "current", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "43.5", "43.5", "", "", "81.4", "70.7", "", "51.6", "", "2", "", "", "102", "1", "2", "10", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "83.7", "81.9", "", "", "", "", "82.2"]} -{"pcdb_id": 8916, "brand_name": "Ideal", "model_name": "Concord CXSD", "model_qualifier": "50/H", "winter_efficiency_pct": 81.1, "summer_efficiency_pct": 70.4, "comparative_hot_water_efficiency_pct": 51.4, "output_kw_max": 54.3, "final_year_of_manufacture": null, "raw": ["008916", "000008", "0", "2012/Mar/27 10:12", "Ideal Boilers", "Ideal", "Concord CXSD", "50/H", "PI No. 87AQ103", "2001", "current", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "54.3", "54.3", "", "", "81.1", "70.4", "", "51.4", "", "2", "", "", "102", "1", "2", "10", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.7", "81.5", "", "", "", "", "81.8"]} -{"pcdb_id": 8917, "brand_name": "Ideal", "model_name": "Concord CXSD", "model_qualifier": "60/H", "winter_efficiency_pct": 81.7, "summer_efficiency_pct": 71.0, "comparative_hot_water_efficiency_pct": 51.8, "output_kw_max": 65.2, "final_year_of_manufacture": null, "raw": ["008917", "000008", "0", "2012/Mar/27 10:12", "Ideal Boilers", "Ideal", "Concord CXSD", "60/H", "PI No. 87AQ103", "2001", "current", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "65.2", "65.2", "", "", "81.7", "71.0", "", "51.8", "", "2", "", "", "102", "1", "2", "10", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.6", "82.7", "", "", "", "", "82.7"]} -{"pcdb_id": 8924, "brand_name": "HRM Boilers", "model_name": "Wallstar 15/20", "model_qualifier": "12", "winter_efficiency_pct": 86.4, "summer_efficiency_pct": 74.7, "comparative_hot_water_efficiency_pct": 54.6, "output_kw_max": 20.0, "final_year_of_manufacture": null, "raw": ["008924", "000098", "0", "2012/Mar/27 10:12", "HRM Boilers", "HRM Boilers", "Wallstar 15/20", "12", "10021108", "2002", "current", "4", "2", "1", "1", "0", "", "", "1", "2", "2", "15", "20", "", "", "86.4", "74.7", "", "54.6", "", "2", "", "", "201", "1", "1", "140", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.6", "86.6", "", "", "", "", "86.6"]} -{"pcdb_id": 8925, "brand_name": "Warmflow", "model_name": "Bluebird", "model_qualifier": "50/70 BB", "winter_efficiency_pct": 85.2, "summer_efficiency_pct": 73.5, "comparative_hot_water_efficiency_pct": 53.7, "output_kw_max": 20.52, "final_year_of_manufacture": null, "raw": ["008925", "000063", "0", "2012/Mar/27 10:12", "Warmflow Engineering", "Warmflow", "Bluebird", "50/70 BB", "", "2000", "current", "4", "1", "2", "1", "0", "", "", "1", "2", "2", "14.65", "20.52", "", "", "85.2", "73.5", "", "53.7", "", "2", "", "", "201", "1", "1", "90", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "84.9", "85.5", "", "", "", "", "85.3"]} -{"pcdb_id": 8926, "brand_name": "Warmflow", "model_name": "Whitebird", "model_qualifier": "50/70 WB", "winter_efficiency_pct": 85.2, "summer_efficiency_pct": 73.5, "comparative_hot_water_efficiency_pct": 53.7, "output_kw_max": 20.52, "final_year_of_manufacture": null, "raw": ["008926", "000063", "0", "2012/Mar/27 10:12", "Warmflow Engineering", "Warmflow", "Whitebird", "50/70 WB", "", "2000", "current", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "14.65", "20.52", "", "", "85.2", "73.5", "", "53.7", "", "2", "", "", "201", "1", "1", "90", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "84.9", "85.5", "", "", "", "", "85.3"]} -{"pcdb_id": 8927, "brand_name": "Warmflow", "model_name": "Goldbird", "model_qualifier": "50/70 GB", "winter_efficiency_pct": 85.2, "summer_efficiency_pct": 73.5, "comparative_hot_water_efficiency_pct": 53.7, "output_kw_max": 20.51, "final_year_of_manufacture": 2006, "raw": ["008927", "000063", "0", "2012/Mar/27 10:12", "Warmflow Engineering", "Warmflow", "Goldbird", "50/70 GB", "", "2000", "2006", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "14.65", "20.51", "", "", "85.2", "73.5", "", "53.7", "", "2", "", "", "201", "1", "1", "90", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "84.9", "85.5", "", "", "", "", "85.3"]} -{"pcdb_id": 8928, "brand_name": "Warmflow", "model_name": "Kabin Pak", "model_qualifier": "50/70 KP", "winter_efficiency_pct": 85.2, "summer_efficiency_pct": 73.5, "comparative_hot_water_efficiency_pct": 53.7, "output_kw_max": 20.52, "final_year_of_manufacture": 2007, "raw": ["008928", "000063", "0", "2012/Mar/27 10:12", "Warmflow Engineering", "Warmflow", "Kabin Pak", "50/70 KP", "", "2000", "2007", "4", "1", "2", "1", "0", "", "", "1", "2", "2", "14.65", "20.52", "", "", "85.2", "73.5", "", "53.7", "", "2", "", "", "201", "1", "1", "90", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "84.9", "85.5", "", "", "", "", "85.3"]} -{"pcdb_id": 8929, "brand_name": "Warmflow", "model_name": "System Whitebird", "model_qualifier": "50/70 SWB", "winter_efficiency_pct": 85.2, "summer_efficiency_pct": 73.5, "comparative_hot_water_efficiency_pct": 53.7, "output_kw_max": 20.52, "final_year_of_manufacture": 2006, "raw": ["008929", "000063", "0", "2012/Mar/27 10:12", "Warmflow Engineering", "Warmflow", "System Whitebird", "50/70 SWB", "", "2001", "2006", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "14.65", "20.52", "", "", "85.2", "73.5", "", "53.7", "", "2", "", "", "201", "1", "1", "90", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "84.9", "85.5", "", "", "", "", "85.3"]} -{"pcdb_id": 8930, "brand_name": "Warmflow", "model_name": "Bluebird", "model_qualifier": "70/90 BB", "winter_efficiency_pct": 85.8, "summer_efficiency_pct": 74.1, "comparative_hot_water_efficiency_pct": 54.1, "output_kw_max": 26.38, "final_year_of_manufacture": null, "raw": ["008930", "000063", "0", "2012/Mar/27 10:12", "Warmflow Engineering", "Warmflow", "Bluebird", "70/90 BB", "", "2000", "current", "4", "1", "2", "1", "0", "", "", "1", "2", "2", "20.52", "26.38", "", "", "85.8", "74.1", "", "54.1", "", "2", "", "", "201", "1", "1", "90", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "84.8", "86.8", "", "", "", "", "86.4"]} -{"pcdb_id": 8931, "brand_name": "Warmflow", "model_name": "Whitebird", "model_qualifier": "70/90 WB", "winter_efficiency_pct": 85.8, "summer_efficiency_pct": 74.1, "comparative_hot_water_efficiency_pct": 54.1, "output_kw_max": 26.38, "final_year_of_manufacture": 2006, "raw": ["008931", "000063", "0", "2012/Mar/27 10:12", "Warmflow Engineering", "Warmflow", "Whitebird", "70/90 WB", "", "2000", "2006", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "20.52", "26.38", "", "", "85.8", "74.1", "", "54.1", "", "2", "", "", "201", "1", "1", "90", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "84.8", "86.8", "", "", "", "", "86.4"]} -{"pcdb_id": 8932, "brand_name": "Warmflow", "model_name": "Goldbird", "model_qualifier": "70/90 GB", "winter_efficiency_pct": 85.8, "summer_efficiency_pct": 74.1, "comparative_hot_water_efficiency_pct": 54.1, "output_kw_max": 26.37, "final_year_of_manufacture": 2006, "raw": ["008932", "000063", "0", "2012/Mar/27 10:12", "Warmflow Engineering", "Warmflow", "Goldbird", "70/90 GB", "", "2000", "2006", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "20.51", "26.37", "", "", "85.8", "74.1", "", "54.1", "", "2", "", "", "201", "1", "1", "90", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "84.8", "86.8", "", "", "", "", "86.4"]} -{"pcdb_id": 8933, "brand_name": "Warmflow", "model_name": "Kabin Pak", "model_qualifier": "70/90 KP", "winter_efficiency_pct": 85.8, "summer_efficiency_pct": 74.1, "comparative_hot_water_efficiency_pct": 54.1, "output_kw_max": 26.38, "final_year_of_manufacture": 2007, "raw": ["008933", "000063", "0", "2012/Mar/27 10:12", "Warmflow Engineering", "Warmflow", "Kabin Pak", "70/90 KP", "", "2000", "2007", "4", "1", "2", "1", "0", "", "", "1", "2", "2", "20.52", "26.38", "", "", "85.8", "74.1", "", "54.1", "", "2", "", "", "201", "1", "1", "90", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "84.8", "86.8", "", "", "", "", "86.4"]} -{"pcdb_id": 8934, "brand_name": "Warmflow", "model_name": "System Whitebird", "model_qualifier": "70/90 SWB", "winter_efficiency_pct": 85.8, "summer_efficiency_pct": 74.1, "comparative_hot_water_efficiency_pct": 54.1, "output_kw_max": 26.38, "final_year_of_manufacture": 2006, "raw": ["008934", "000063", "0", "2012/Mar/27 10:12", "Warmflow Engineering", "Warmflow", "System Whitebird", "70/90 SWB", "", "2001", "2006", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "20.52", "26.38", "", "", "85.8", "74.1", "", "54.1", "", "2", "", "", "201", "1", "1", "90", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "84.8", "86.8", "", "", "", "", "86.4"]} -{"pcdb_id": 8935, "brand_name": "Warmflow", "model_name": "Combi", "model_qualifier": "70/90 Combi", "winter_efficiency_pct": 83.9, "summer_efficiency_pct": 75.8, "comparative_hot_water_efficiency_pct": 40.9, "output_kw_max": 26.38, "final_year_of_manufacture": 2007, "raw": ["008935", "000063", "0", "2024/Jan/31 10:17", "Warmflow Engineering", "Warmflow", "Combi", "70/90 Combi", "", "2001", "2007", "4", "1", "1", "2", "0", "", "", "1", "2", "2", "20.52", "26.38", "", "", "83.9", "75.8", "", "40.9", "", "2", "", "", "203", "1", "1", "90", "0", "1", "1", "0", "50", "0", "25", "3", "80", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "84.8", "86.8", "", "", "", "", "86.4"]} -{"pcdb_id": 8936, "brand_name": "Warmflow", "model_name": "Bluebird", "model_qualifier": "90/120 BB", "winter_efficiency_pct": 86.2, "summer_efficiency_pct": 74.5, "comparative_hot_water_efficiency_pct": 54.4, "output_kw_max": 35.17, "final_year_of_manufacture": null, "raw": ["008936", "000063", "0", "2012/Mar/27 10:12", "Warmflow Engineering", "Warmflow", "Bluebird", "90/120 BB", "", "2000", "current", "4", "1", "2", "1", "0", "", "", "1", "2", "2", "26.38", "35.17", "", "", "86.2", "74.5", "", "54.4", "", "2", "", "", "201", "1", "1", "90", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.0", "86.4", "", "", "", "", "86.3"]} -{"pcdb_id": 8937, "brand_name": "Warmflow", "model_name": "Whitebird", "model_qualifier": "90/120 WB", "winter_efficiency_pct": 86.2, "summer_efficiency_pct": 74.5, "comparative_hot_water_efficiency_pct": 54.4, "output_kw_max": 35.17, "final_year_of_manufacture": null, "raw": ["008937", "000063", "0", "2012/Mar/27 10:12", "Warmflow Engineering", "Warmflow", "Whitebird", "90/120 WB", "", "2000", "current", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "26.38", "35.17", "", "", "86.2", "74.5", "", "54.4", "", "2", "", "", "201", "1", "1", "90", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.0", "86.4", "", "", "", "", "86.3"]} -{"pcdb_id": 8938, "brand_name": "Warmflow", "model_name": "Goldbird", "model_qualifier": "90/120 GB", "winter_efficiency_pct": 86.2, "summer_efficiency_pct": 74.5, "comparative_hot_water_efficiency_pct": 54.4, "output_kw_max": 35.16, "final_year_of_manufacture": null, "raw": ["008938", "000063", "0", "2012/Mar/27 10:12", "Warmflow Engineering", "Warmflow", "Goldbird", "90/120 GB", "", "2000", "current", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "26.37", "35.16", "", "", "86.2", "74.5", "", "54.4", "", "2", "", "", "201", "1", "1", "90", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.0", "86.4", "", "", "", "", "86.3"]} -{"pcdb_id": 8939, "brand_name": "Warmflow", "model_name": "Kabin Pak", "model_qualifier": "90/120 KP", "winter_efficiency_pct": 86.2, "summer_efficiency_pct": 74.5, "comparative_hot_water_efficiency_pct": 54.4, "output_kw_max": 35.17, "final_year_of_manufacture": null, "raw": ["008939", "000063", "0", "2012/Mar/27 10:12", "Warmflow Engineering", "Warmflow", "Kabin Pak", "90/120 KP", "", "2000", "current", "4", "1", "2", "1", "0", "", "", "1", "2", "2", "26.38", "35.17", "", "", "86.2", "74.5", "", "54.4", "", "2", "", "", "201", "1", "1", "90", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.0", "86.4", "", "", "", "", "86.3"]} -{"pcdb_id": 8940, "brand_name": "Warmflow", "model_name": "Bluebird", "model_qualifier": "120/150 BB", "winter_efficiency_pct": 86.5, "summer_efficiency_pct": 74.8, "comparative_hot_water_efficiency_pct": 54.7, "output_kw_max": 44.0, "final_year_of_manufacture": null, "raw": ["008940", "000063", "0", "2012/Mar/27 10:12", "Warmflow Engineering", "Warmflow", "Bluebird", "120/150 BB", "", "1996", "current", "4", "1", "2", "1", "0", "", "", "1", "2", "2", "35.17", "44.0", "", "", "86.5", "74.8", "", "54.7", "", "2", "", "", "201", "1", "1", "90", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.9", "88.0", "", "", "", "", "87.6"]} -{"pcdb_id": 8941, "brand_name": "Warmflow", "model_name": "Goldbird", "model_qualifier": "120/150 GB", "winter_efficiency_pct": 86.5, "summer_efficiency_pct": 74.8, "comparative_hot_water_efficiency_pct": 54.7, "output_kw_max": 44.0, "final_year_of_manufacture": null, "raw": ["008941", "000063", "0", "2012/Mar/27 10:12", "Warmflow Engineering", "Warmflow", "Goldbird", "120/150 GB", "", "1996", "current", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "35.17", "44.0", "", "", "86.5", "74.8", "", "54.7", "", "2", "", "", "201", "1", "1", "90", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.9", "88.0", "", "", "", "", "87.6"]} -{"pcdb_id": 8942, "brand_name": "Warmflow", "model_name": "Whitebird", "model_qualifier": "120/150 WB", "winter_efficiency_pct": 86.5, "summer_efficiency_pct": 74.8, "comparative_hot_water_efficiency_pct": 54.7, "output_kw_max": 44.0, "final_year_of_manufacture": null, "raw": ["008942", "000063", "0", "2012/Mar/27 10:12", "Warmflow Engineering", "Warmflow", "Whitebird", "120/150 WB", "", "1996", "current", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "35.17", "44.0", "", "", "86.5", "74.8", "", "54.7", "", "2", "", "", "201", "1", "1", "90", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.9", "88.0", "", "", "", "", "87.6"]} -{"pcdb_id": 8943, "brand_name": "Firebird", "model_name": "Popular", "model_qualifier": "120-150", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 43.96, "final_year_of_manufacture": 2013, "raw": ["008943", "000047", "0", "2018/Jan/03 11:58", "Firebird Boilers", "Firebird", "Popular", "120-150", "", "", "2013", "4", "1", "1", "1", "0", "", "", "1", "2", "1", "35.17", "43.96", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.3", "87.2", "", "", "", "", "87.1"]} -{"pcdb_id": 8944, "brand_name": "Firebird", "model_name": "Heatpac", "model_qualifier": "120-150", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 43.96, "final_year_of_manufacture": 2013, "raw": ["008944", "000047", "0", "2018/Jan/03 11:59", "Firebird Boilers", "Firebird", "Heatpac", "120-150", "", "", "2013", "4", "1", "2", "1", "0", "", "", "1", "1", "1", "35.17", "43.96", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.3", "87.2", "", "", "", "", "87.1"]} -{"pcdb_id": 8945, "brand_name": "Firebird", "model_name": "Boilerhouse S", "model_qualifier": "120-150", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 43.96, "final_year_of_manufacture": 2013, "raw": ["008945", "000047", "0", "2018/Jan/03 12:01", "Firebird Boilers", "Firebird", "Boilerhouse S", "120-150", "", "", "2013", "4", "1", "1", "1", "0", "", "", "1", "2", "1", "35.17", "43.96", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.3", "87.2", "", "", "", "", "87.1"]} -{"pcdb_id": 8946, "brand_name": "Firebird", "model_name": "Roomsealed Popular (Hideaway)", "model_qualifier": "120-150", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 43.96, "final_year_of_manufacture": 2010, "raw": ["008946", "000047", "0", "2012/Mar/27 10:12", "Firebird Boilers", "Firebird", "Roomsealed Popular (Hideaway)", "120-150", "", "", "2010", "4", "1", "1", "1", "0", "", "", "1", "2", "1", "35.17", "43.96", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.3", "87.2", "", "", "", "", "87.1"]} -{"pcdb_id": 8947, "brand_name": "Firebird", "model_name": "S (White Cased)", "model_qualifier": "120-150", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 43.96, "final_year_of_manufacture": 2013, "raw": ["008947", "000047", "0", "2018/Jan/03 12:03", "Firebird Boilers", "Firebird", "S (White Cased)", "120-150", "", "", "2013", "4", "1", "1", "1", "0", "", "", "1", "2", "1", "35.17", "43.96", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.3", "87.2", "", "", "", "", "87.1"]} -{"pcdb_id": 8948, "brand_name": "Hepworth Heating", "model_name": "Halstead Buckingham 4 40BFF", "model_qualifier": "", "winter_efficiency_pct": 79.2, "summer_efficiency_pct": 69.1, "comparative_hot_water_efficiency_pct": 50.5, "output_kw_max": 11.72, "final_year_of_manufacture": 2006, "raw": ["008948", "000019", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Hepworth Heating", "Halstead Buckingham 4 40BFF", "", "41-333-88", "2002", "2006", "1", "1", "1", "1", "0", "", "", "1", "2", "2", "11.72", "11.72", "", "", "79.2", "69.1", "", "50.5", "", "2", "", "", "101", "1", "1", "37", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.7", "79.8", "", "", "", "", "80.2"]} -{"pcdb_id": 8949, "brand_name": "Hepworth Heating", "model_name": "Halstead Buckingham 4 40CFF", "model_qualifier": "", "winter_efficiency_pct": 79.2, "summer_efficiency_pct": 69.1, "comparative_hot_water_efficiency_pct": 50.5, "output_kw_max": 11.72, "final_year_of_manufacture": 2006, "raw": ["008949", "000019", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Hepworth Heating", "Halstead Buckingham 4 40CFF", "", "41-333-94", "2002", "2006", "1", "1", "1", "1", "0", "", "", "1", "2", "2", "11.72", "11.72", "", "", "79.2", "69.1", "", "50.5", "", "2", "", "", "101", "1", "1", "37", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.7", "79.8", "", "", "", "", "80.2"]} -{"pcdb_id": 8950, "brand_name": "Hepworth Heating", "model_name": "Halstead Buckingham 4 50BFF", "model_qualifier": "", "winter_efficiency_pct": 79.1, "summer_efficiency_pct": 69.0, "comparative_hot_water_efficiency_pct": 50.4, "output_kw_max": 14.65, "final_year_of_manufacture": 2006, "raw": ["008950", "000019", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Hepworth Heating", "Halstead Buckingham 4 50BFF", "", "41-333-89", "2002", "2006", "1", "1", "1", "1", "0", "", "", "1", "2", "2", "14.65", "14.65", "", "", "79.1", "69.0", "", "50.4", "", "2", "", "", "101", "1", "1", "37", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.6", "79.7", "", "", "", "", "80.1"]} -{"pcdb_id": 8951, "brand_name": "Hepworth Heating", "model_name": "Halstead Buckingham 4 50CFF", "model_qualifier": "", "winter_efficiency_pct": 79.1, "summer_efficiency_pct": 69.0, "comparative_hot_water_efficiency_pct": 50.4, "output_kw_max": 14.65, "final_year_of_manufacture": 2006, "raw": ["008951", "000019", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Hepworth Heating", "Halstead Buckingham 4 50CFF", "", "41-333-95", "2002", "2006", "1", "1", "1", "1", "0", "", "", "1", "1", "2", "14.65", "14.65", "", "", "79.1", "69.0", "", "50.4", "", "2", "", "", "101", "1", "1", "37", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.6", "79.7", "", "", "", "", "80.1"]} -{"pcdb_id": 8952, "brand_name": "Hepworth Heating", "model_name": "Halstead Buckingham 4 60CFF", "model_qualifier": "", "winter_efficiency_pct": 79.4, "summer_efficiency_pct": 69.3, "comparative_hot_water_efficiency_pct": 50.6, "output_kw_max": 17.0, "final_year_of_manufacture": 2006, "raw": ["008952", "000019", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Hepworth Heating", "Halstead Buckingham 4 60CFF", "", "41-333-96", "2002", "2006", "1", "1", "1", "1", "0", "", "", "1", "1", "2", "17", "17", "", "", "79.4", "69.3", "", "50.6", "", "2", "", "", "101", "1", "1", "37", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.5", "80.4", "", "", "", "", "80.6"]} -{"pcdb_id": 8953, "brand_name": "Hepworth Heating", "model_name": "Halstead Buckingham 4 60BFF", "model_qualifier": "", "winter_efficiency_pct": 79.4, "summer_efficiency_pct": 69.3, "comparative_hot_water_efficiency_pct": 50.6, "output_kw_max": 17.0, "final_year_of_manufacture": 2006, "raw": ["008953", "000019", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Hepworth Heating", "Halstead Buckingham 4 60BFF", "", "41-333-90", "2002", "2006", "1", "1", "1", "1", "0", "", "", "1", "2", "2", "17", "17", "", "", "79.4", "69.3", "", "50.6", "", "2", "", "", "101", "1", "1", "37", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.5", "80.4", "", "", "", "", "80.6"]} -{"pcdb_id": 8954, "brand_name": "Hepworth Heating", "model_name": "Halstead Buckingham 4 80CFF", "model_qualifier": "", "winter_efficiency_pct": 79.3, "summer_efficiency_pct": 69.2, "comparative_hot_water_efficiency_pct": 50.6, "output_kw_max": 23.45, "final_year_of_manufacture": 2006, "raw": ["008954", "000019", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Hepworth Heating", "Halstead Buckingham 4 80CFF", "", "41-333-97", "2002", "2006", "1", "1", "1", "1", "0", "", "", "1", "1", "2", "23.45", "23.45", "", "", "79.3", "69.2", "", "50.6", "", "2", "", "", "101", "1", "1", "49", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.5", "80.4", "", "", "", "", "80.6"]} -{"pcdb_id": 8955, "brand_name": "Hepworth Heating", "model_name": "Halstead Buckingham 4 80BFF", "model_qualifier": "", "winter_efficiency_pct": 79.3, "summer_efficiency_pct": 69.2, "comparative_hot_water_efficiency_pct": 50.6, "output_kw_max": 23.45, "final_year_of_manufacture": 2006, "raw": ["008955", "000019", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Hepworth Heating", "Halstead Buckingham 4 80BFF", "", "41-333-91", "2002", "2006", "1", "1", "1", "1", "0", "", "", "1", "2", "2", "23.45", "23.45", "", "", "79.3", "69.2", "", "50.6", "", "2", "", "", "101", "1", "1", "49", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.5", "80.4", "", "", "", "", "80.6"]} -{"pcdb_id": 8956, "brand_name": "Hepworth Heating", "model_name": "Halstead Buckingham 4 100CFF", "model_qualifier": "", "winter_efficiency_pct": 81.2, "summer_efficiency_pct": 71.1, "comparative_hot_water_efficiency_pct": 51.9, "output_kw_max": 29.31, "final_year_of_manufacture": 2006, "raw": ["008956", "000019", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Hepworth Heating", "Halstead Buckingham 4 100CFF", "", "41-333-98", "2002", "2006", "1", "1", "1", "1", "0", "", "", "1", "1", "2", "29.31", "29.31", "", "", "81.2", "71.1", "", "51.9", "", "2", "", "", "101", "1", "1", "49", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "83.6", "82.7", "", "", "", "", "82.9"]} -{"pcdb_id": 8957, "brand_name": "Hepworth Heating", "model_name": "Halstead Buckingham 4 100BFF", "model_qualifier": "", "winter_efficiency_pct": 81.2, "summer_efficiency_pct": 71.1, "comparative_hot_water_efficiency_pct": 51.9, "output_kw_max": 29.31, "final_year_of_manufacture": 2006, "raw": ["008957", "000019", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Hepworth Heating", "Halstead Buckingham 4 100BFF", "", "41-333-92", "2002", "2006", "1", "1", "1", "1", "0", "", "", "1", "2", "2", "29.31", "29.31", "", "", "81.2", "71.1", "", "51.9", "", "2", "", "", "101", "1", "1", "49", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "83.6", "82.7", "", "", "", "", "82.9"]} -{"pcdb_id": 8958, "brand_name": "Hepworth Heating", "model_name": "Halstead Buckingham 4 115CFF", "model_qualifier": "", "winter_efficiency_pct": 79.6, "summer_efficiency_pct": 69.5, "comparative_hot_water_efficiency_pct": 50.8, "output_kw_max": 33.7, "final_year_of_manufacture": 2006, "raw": ["008958", "000019", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Hepworth Heating", "Halstead Buckingham 4 115CFF", "", "41-333-99", "2002", "2006", "1", "1", "1", "1", "0", "", "", "1", "1", "2", "33.7", "33.7", "", "", "79.6", "69.5", "", "50.8", "", "2", "", "", "101", "1", "1", "49", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.5", "80.9", "", "", "", "", "81.0"]} -{"pcdb_id": 8959, "brand_name": "Hepworth Heating", "model_name": "Halstead Buckingham 4 115BFF", "model_qualifier": "", "winter_efficiency_pct": 79.6, "summer_efficiency_pct": 69.5, "comparative_hot_water_efficiency_pct": 50.8, "output_kw_max": 33.7, "final_year_of_manufacture": 2006, "raw": ["008959", "000019", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Hepworth Heating", "Halstead Buckingham 4 115BFF", "", "41-333-93", "2002", "2006", "1", "1", "1", "1", "0", "", "", "1", "2", "2", "33.7", "33.7", "", "", "79.6", "69.5", "", "50.8", "", "2", "", "", "101", "1", "1", "49", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.5", "80.9", "", "", "", "", "81.0"]} -{"pcdb_id": 8960, "brand_name": "Glow-worm", "model_name": "Hideaway 40BFF", "model_qualifier": "", "winter_efficiency_pct": 79.2, "summer_efficiency_pct": 69.1, "comparative_hot_water_efficiency_pct": 50.5, "output_kw_max": 11.72, "final_year_of_manufacture": null, "raw": ["008960", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Hideaway 40BFF", "", "41 047 32", "2002", "current", "1", "1", "1", "1", "0", "", "", "1", "2", "2", "11.72", "11.72", "", "", "79.2", "69.1", "", "50.5", "", "2", "", "", "101", "1", "1", "37", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.7", "79.8", "", "", "", "", "80.2"]} -{"pcdb_id": 8961, "brand_name": "Glow-worm", "model_name": "Hideaway 40CFF", "model_qualifier": "", "winter_efficiency_pct": 79.2, "summer_efficiency_pct": 69.1, "comparative_hot_water_efficiency_pct": 50.5, "output_kw_max": 11.72, "final_year_of_manufacture": null, "raw": ["008961", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Hideaway 40CFF", "", "41 047 32", "2002", "current", "1", "1", "1", "1", "0", "", "", "1", "2", "2", "11.72", "11.72", "", "", "79.2", "69.1", "", "50.5", "", "2", "", "", "101", "1", "1", "37", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.7", "79.8", "", "", "", "", "80.2"]} -{"pcdb_id": 8962, "brand_name": "Glow-worm", "model_name": "Hideaway 50BFF", "model_qualifier": "", "winter_efficiency_pct": 79.1, "summer_efficiency_pct": 69.0, "comparative_hot_water_efficiency_pct": 50.4, "output_kw_max": 14.65, "final_year_of_manufacture": null, "raw": ["008962", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Hideaway 50BFF", "", "41 047 33", "2002", "current", "1", "1", "1", "1", "0", "", "", "1", "2", "2", "14.65", "14.65", "", "", "79.1", "69.0", "", "50.4", "", "2", "", "", "101", "1", "1", "37", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.6", "79.7", "", "", "", "", "80.1"]} -{"pcdb_id": 8963, "brand_name": "Glow-worm", "model_name": "Hideaway 50CFF", "model_qualifier": "", "winter_efficiency_pct": 79.1, "summer_efficiency_pct": 69.0, "comparative_hot_water_efficiency_pct": 50.4, "output_kw_max": 14.65, "final_year_of_manufacture": null, "raw": ["008963", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Hideaway 50CFF", "", "41 047 39", "2002", "current", "1", "1", "1", "1", "0", "", "", "1", "1", "2", "14.65", "14.65", "", "", "79.1", "69.0", "", "50.4", "", "2", "", "", "101", "1", "1", "37", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.6", "79.7", "", "", "", "", "80.1"]} -{"pcdb_id": 8964, "brand_name": "Glow-worm", "model_name": "Hideaway 60CFF", "model_qualifier": "", "winter_efficiency_pct": 79.4, "summer_efficiency_pct": 69.3, "comparative_hot_water_efficiency_pct": 50.6, "output_kw_max": 17.0, "final_year_of_manufacture": null, "raw": ["008964", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Hideaway 60CFF", "", "41 047 40", "2002", "current", "1", "1", "1", "1", "0", "", "", "1", "1", "2", "17", "17", "", "", "79.4", "69.3", "", "50.6", "", "2", "", "", "101", "1", "1", "37", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.5", "80.4", "", "", "", "", "80.6"]} -{"pcdb_id": 8965, "brand_name": "Glow-worm", "model_name": "Hideaway 60BFF", "model_qualifier": "", "winter_efficiency_pct": 79.4, "summer_efficiency_pct": 69.3, "comparative_hot_water_efficiency_pct": 50.6, "output_kw_max": 17.0, "final_year_of_manufacture": 2006, "raw": ["008965", "000207", "0", "2018/Oct/15 12:00", "Hepworth Heating", "Glow-worm", "Hideaway 60BFF", "", "41 047 34", "2002", "2006", "1", "1", "1", "1", "0", "", "", "1", "2", "2", "17", "17", "", "", "79.4", "69.3", "", "50.6", "", "2", "", "", "101", "1", "1", "37", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.5", "80.4", "", "", "", "", "80.6"]} -{"pcdb_id": 8966, "brand_name": "Glow-worm", "model_name": "Hideaway 80CFF", "model_qualifier": "", "winter_efficiency_pct": 79.3, "summer_efficiency_pct": 69.2, "comparative_hot_water_efficiency_pct": 50.6, "output_kw_max": 23.45, "final_year_of_manufacture": null, "raw": ["008966", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Hideaway 80CFF", "", "41 047 41", "2002", "current", "1", "1", "1", "1", "0", "", "", "1", "1", "2", "23.45", "23.45", "", "", "79.3", "69.2", "", "50.6", "", "2", "", "", "101", "1", "1", "49", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.5", "80.4", "", "", "", "", "80.6"]} -{"pcdb_id": 8967, "brand_name": "Glow-worm", "model_name": "Hideaway 80BFF", "model_qualifier": "", "winter_efficiency_pct": 79.3, "summer_efficiency_pct": 69.2, "comparative_hot_water_efficiency_pct": 50.6, "output_kw_max": 23.45, "final_year_of_manufacture": null, "raw": ["008967", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Hideaway 80BFF", "", "41 047 35", "2002", "current", "1", "1", "1", "1", "0", "", "", "1", "2", "2", "23.45", "23.45", "", "", "79.3", "69.2", "", "50.6", "", "2", "", "", "101", "1", "1", "49", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.5", "80.4", "", "", "", "", "80.6"]} -{"pcdb_id": 8968, "brand_name": "Glow-worm", "model_name": "Hideaway 100CFF", "model_qualifier": "", "winter_efficiency_pct": 81.2, "summer_efficiency_pct": 71.1, "comparative_hot_water_efficiency_pct": 51.9, "output_kw_max": 29.31, "final_year_of_manufacture": null, "raw": ["008968", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Hideaway 100CFF", "", "41 047 42", "2002", "current", "1", "1", "1", "1", "0", "", "", "1", "1", "2", "29.31", "29.31", "", "", "81.2", "71.1", "", "51.9", "", "2", "", "", "101", "1", "1", "49", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "83.6", "82.7", "", "", "", "", "82.9"]} -{"pcdb_id": 8969, "brand_name": "Glow-worm", "model_name": "Hideaway 100BFF", "model_qualifier": "", "winter_efficiency_pct": 81.2, "summer_efficiency_pct": 71.1, "comparative_hot_water_efficiency_pct": 51.9, "output_kw_max": 29.31, "final_year_of_manufacture": null, "raw": ["008969", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Hideaway 100BFF", "", "41 047 36", "2002", "current", "1", "1", "1", "1", "0", "", "", "1", "2", "2", "29.31", "29.31", "", "", "81.2", "71.1", "", "51.9", "", "2", "", "", "101", "1", "1", "49", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "83.6", "82.7", "", "", "", "", "82.9"]} -{"pcdb_id": 8970, "brand_name": "Glow-worm", "model_name": "Hideaway 115CFF", "model_qualifier": "", "winter_efficiency_pct": 79.6, "summer_efficiency_pct": 69.5, "comparative_hot_water_efficiency_pct": 50.8, "output_kw_max": 33.7, "final_year_of_manufacture": null, "raw": ["008970", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Hideaway 115CFF", "", "41 047 43", "2002", "current", "1", "1", "1", "1", "0", "", "", "1", "1", "2", "33.7", "33.7", "", "", "79.6", "69.5", "", "50.8", "", "2", "", "", "101", "1", "1", "49", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.5", "80.9", "", "", "", "", "81.0"]} -{"pcdb_id": 8971, "brand_name": "Glow-worm", "model_name": "Hideaway 115BFF", "model_qualifier": "", "winter_efficiency_pct": 79.6, "summer_efficiency_pct": 69.5, "comparative_hot_water_efficiency_pct": 50.8, "output_kw_max": 33.7, "final_year_of_manufacture": null, "raw": ["008971", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Hideaway 115BFF", "", "41 047 37", "2002", "current", "1", "1", "1", "1", "0", "", "", "1", "2", "2", "33.7", "33.7", "", "", "79.6", "69.5", "", "50.8", "", "2", "", "", "101", "1", "1", "49", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.5", "80.9", "", "", "", "", "81.0"]} -{"pcdb_id": 8972, "brand_name": "Boulter", "model_name": "Classic", "model_qualifier": "135/165A", "winter_efficiency_pct": 85.7, "summer_efficiency_pct": 74.0, "comparative_hot_water_efficiency_pct": 54.1, "output_kw_max": 48.4, "final_year_of_manufacture": 2005, "raw": ["008972", "000041", "0", "2012/Mar/27 10:12", "Boulter Boilers", "Boulter", "Classic", "135/165A", "", "2002", "2005", "4", "1", "1", "1", "0", "", "", "1", "3", "2", "39.5", "48.4", "", "", "85.7", "74.0", "", "54.1", "", "2", "", "", "201", "1", "1", "150", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.4", "86.1", "", "", "", "", "86.0"]} -{"pcdb_id": 8973, "brand_name": "Boulter", "model_name": "Bonus", "model_qualifier": "Combi 90A", "winter_efficiency_pct": 83.4, "summer_efficiency_pct": 75.3, "comparative_hot_water_efficiency_pct": 35.4, "output_kw_max": 26.4, "final_year_of_manufacture": null, "raw": ["008973", "000041", "0", "2024/Jan/31 10:17", "Boulter Boilers", "Boulter", "Bonus", "Combi 90A", "", "2002", "obsolete", "4", "1", "2", "2", "0", "", "", "1", "3", "2", "26.4", "26.4", "", "", "83.4", "75.3", "", "35.4", "", "2", "", "", "203", "1", "1", "145", "0", "1", "1", "0", "40", "0", "15", "3", "82", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "84.8", "85.7", "", "", "", "", "85.6"]} -{"pcdb_id": 8976, "brand_name": "Worcester", "model_name": "26 CDi Xtra", "model_qualifier": "RSF", "winter_efficiency_pct": 85.9, "summer_efficiency_pct": 77.3, "comparative_hot_water_efficiency_pct": 54.3, "output_kw_max": 26.0, "final_year_of_manufacture": 2005, "raw": ["008976", "000035", "0", "2020/Sep/04 08:01", "Worcester Heat Systems", "Worcester", "26 CDi Xtra", "RSF", "47 311 42", "1998", "2005", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "26", "26", "", "", "85.9", "77.3", "", "54.3", "", "2", "1", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "92.0", "", "", "", "", "91.2"]} -{"pcdb_id": 8977, "brand_name": "Worcester", "model_name": "15 SBi", "model_qualifier": "RSF", "winter_efficiency_pct": 81.8, "summer_efficiency_pct": 71.7, "comparative_hot_water_efficiency_pct": 52.4, "output_kw_max": 15.0, "final_year_of_manufacture": 2005, "raw": ["008977", "000035", "0", "2020/Sep/04 08:01", "Worcester Heat Systems", "Worcester", "15 SBi", "RSF", "41 311 45", "1999", "2005", "2", "2", "1", "1", "0", "", "", "1", "2", "2", "6", "15", "", "", "81.8", "71.7", "", "52.4", "", "2", "1", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "83.0", "85.4", "", "", "", "", "84.9"]} -{"pcdb_id": 8978, "brand_name": "Worcester", "model_name": "24 SBi", "model_qualifier": "RSF", "winter_efficiency_pct": 81.0, "summer_efficiency_pct": 70.9, "comparative_hot_water_efficiency_pct": 51.8, "output_kw_max": 24.0, "final_year_of_manufacture": 2005, "raw": ["008978", "000035", "0", "2020/Sep/04 08:02", "Worcester Heat Systems", "Worcester", "24 SBi", "RSF", "41 311 46", "1999", "2005", "2", "2", "1", "1", "0", "", "", "1", "2", "2", "15", "24", "", "", "81.0", "70.9", "", "51.8", "", "2", "1", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "84.4", "80.8", "", "", "", "", "81.5"]} -{"pcdb_id": 8979, "brand_name": "Trianco", "model_name": "Eurotrader", "model_qualifier": "50/90", "winter_efficiency_pct": 86.5, "summer_efficiency_pct": 74.8, "comparative_hot_water_efficiency_pct": 54.7, "output_kw_max": 26.3, "final_year_of_manufacture": null, "raw": ["008979", "000062", "0", "2012/Mar/27 10:12", "Trianco Redfyre", "Trianco", "Eurotrader", "50/90", "13961/2", "1997", "current", "4", "1", "2", "1", "0", "", "", "1", "1", "1", "14.65", "26.3", "", "", "86.5", "74.8", "", "54.7", "", "2", "", "", "201", "1", "1", "148", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.9", "88.8", "", "", "", "", "88.3"]} -{"pcdb_id": 8980, "brand_name": "Trianco", "model_name": "Eurostar", "model_qualifier": "Combi 90", "winter_efficiency_pct": 84.6, "summer_efficiency_pct": 76.5, "comparative_hot_water_efficiency_pct": 45.6, "output_kw_max": 27.5, "final_year_of_manufacture": 2007, "raw": ["008980", "000062", "0", "2024/Jan/31 10:17", "Trianco Redfyre", "Trianco", "Eurostar", "Combi 90", "12579/1", "1997", "2007", "4", "1", "2", "2", "0", "", "", "1", "1", "1", "20.5", "27.5", "", "", "84.6", "76.5", "", "45.6", "", "2", "", "", "203", "1", "1", "1.2", "5.5", "2", "1", "0", "63", "0", "25", "1", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.9", "88.8", "", "", "", "", "88.3"]} -{"pcdb_id": 8981, "brand_name": "Trianco", "model_name": "Eurostar", "model_qualifier": "External 65 wm", "winter_efficiency_pct": 86.6, "summer_efficiency_pct": 74.9, "comparative_hot_water_efficiency_pct": 54.7, "output_kw_max": 19.0, "final_year_of_manufacture": 2007, "raw": ["008981", "000062", "0", "2012/Mar/27 10:12", "Trianco Redfyre", "Trianco", "Eurostar", "External 65 wm", "13961/10", "1998", "2007", "4", "2", "2", "1", "0", "", "", "1", "1", "1", "14.6", "19", "", "", "86.6", "74.9", "", "54.7", "", "2", "", "", "201", "1", "1", "148", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.1", "87.8", "", "", "", "", "87.5"]} -{"pcdb_id": 8982, "brand_name": "Trianco", "model_name": "Eurostar", "model_qualifier": "Utility 190/240", "winter_efficiency_pct": 86.3, "summer_efficiency_pct": 74.6, "comparative_hot_water_efficiency_pct": 54.5, "output_kw_max": 70.0, "final_year_of_manufacture": 2007, "raw": ["008982", "000062", "0", "2012/Mar/27 10:12", "Trianco Redfyre", "Trianco", "Eurostar", "Utility 190/240", "13961/6", "1998", "2007", "4", "1", "2", "1", "0", "", "", "1", "1", "1", "55.7", "70", "", "", "86.3", "74.6", "", "54.5", "", "2", "", "", "201", "1", "1", "148", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.1", "86.6", "", "", "", "", "86.5"]} -{"pcdb_id": 8983, "brand_name": "Trianco", "model_name": "Eurostar", "model_qualifier": "Utility 160/180", "winter_efficiency_pct": 86.3, "summer_efficiency_pct": 74.6, "comparative_hot_water_efficiency_pct": 54.5, "output_kw_max": 52.7, "final_year_of_manufacture": 2007, "raw": ["008983", "000062", "0", "2012/Mar/27 10:12", "Trianco Redfyre", "Trianco", "Eurostar", "Utility 160/180", "13161/5", "1998", "2007", "4", "1", "2", "1", "0", "", "", "1", "1", "1", "46.9", "52.7", "", "", "86.3", "74.6", "", "54.5", "", "2", "", "", "201", "1", "1", "148", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.8", "86.8", "", "", "", "", "86.6"]} -{"pcdb_id": 8985, "brand_name": "Trianco", "model_name": "Iona", "model_qualifier": "100/125", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 36.6, "final_year_of_manufacture": null, "raw": ["008985", "000062", "0", "2012/Mar/27 10:12", "Trianco Redfyre", "Trianco", "Iona", "100/125", "13961/3", "1997", "current", "4", "1", "2", "1", "0", "", "", "1", "1", "1", "29.3", "36.6", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "148", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.4", "90.5", "", "", "", "", "89.7"]} -{"pcdb_id": 8986, "brand_name": "Trianco", "model_name": "Eurostar", "model_qualifier": "Utility 100/125", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 36.6, "final_year_of_manufacture": 2007, "raw": ["008986", "000062", "0", "2012/Mar/27 10:12", "Trianco Redfyre", "Trianco", "Eurostar", "Utility 100/125", "13961/3", "1997", "2007", "4", "1", "2", "1", "0", "", "", "1", "1", "1", "29.3", "36.6", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "148", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.4", "90.5", "", "", "", "", "89.7"]} -{"pcdb_id": 8988, "brand_name": "Trianco", "model_name": "Eurotrader", "model_qualifier": "100/125", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 36.6, "final_year_of_manufacture": null, "raw": ["008988", "000062", "0", "2012/Mar/27 10:12", "Trianco Redfyre", "Trianco", "Eurotrader", "100/125", "13961/3", "1997", "current", "4", "1", "2", "1", "0", "", "", "1", "1", "1", "29.3", "36.6", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "148", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.4", "90.5", "", "", "", "", "89.7"]} -{"pcdb_id": 8989, "brand_name": "Trianco", "model_name": "Eurostar", "model_qualifier": "External 50/90", "winter_efficiency_pct": 86.5, "summer_efficiency_pct": 74.8, "comparative_hot_water_efficiency_pct": 54.7, "output_kw_max": 26.3, "final_year_of_manufacture": 2007, "raw": ["008989", "000062", "0", "2012/Mar/27 10:12", "Trianco Redfyre", "Trianco", "Eurostar", "External 50/90", "13961/2", "1997", "2007", "4", "1", "2", "1", "0", "", "", "1", "1", "1", "14.65", "26.3", "", "", "86.5", "74.8", "", "54.7", "", "2", "", "", "201", "1", "1", "148", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.9", "88.8", "", "", "", "", "88.3"]} -{"pcdb_id": 8990, "brand_name": "Trianco", "model_name": "Eurostar", "model_qualifier": "2000 70/90", "winter_efficiency_pct": 86.5, "summer_efficiency_pct": 74.8, "comparative_hot_water_efficiency_pct": 54.7, "output_kw_max": 26.3, "final_year_of_manufacture": 2007, "raw": ["008990", "000062", "0", "2012/Mar/27 10:12", "Trianco Redfyre", "Trianco", "Eurostar", "2000 70/90", "13961/2", "1997", "2007", "4", "1", "2", "1", "0", "", "", "1", "1", "1", "20.5", "26.3", "", "", "86.5", "74.8", "", "54.7", "", "2", "", "", "201", "1", "1", "148", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.9", "88.8", "", "", "", "", "88.3"]} -{"pcdb_id": 8991, "brand_name": "Trianco", "model_name": "Iona", "model_qualifier": "50/90", "winter_efficiency_pct": 86.5, "summer_efficiency_pct": 74.8, "comparative_hot_water_efficiency_pct": 54.7, "output_kw_max": 26.3, "final_year_of_manufacture": null, "raw": ["008991", "000062", "0", "2012/Mar/27 10:12", "Trianco Redfyre", "Trianco", "Iona", "50/90", "13961/2", "1997", "current", "4", "1", "2", "1", "0", "", "", "1", "1", "1", "14.65", "26.3", "", "", "86.5", "74.8", "", "54.7", "", "2", "", "", "201", "1", "1", "148", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.9", "88.8", "", "", "", "", "88.3"]} -{"pcdb_id": 8992, "brand_name": "Trianco", "model_name": "Eurostar", "model_qualifier": "Utility System 50/90", "winter_efficiency_pct": 86.5, "summer_efficiency_pct": 74.8, "comparative_hot_water_efficiency_pct": 54.7, "output_kw_max": 26.3, "final_year_of_manufacture": 2007, "raw": ["008992", "000062", "0", "2012/Mar/27 10:12", "Trianco Redfyre", "Trianco", "Eurostar", "Utility System 50/90", "13961/2", "1997", "2007", "4", "1", "2", "1", "0", "", "", "1", "1", "1", "20.5", "26.3", "", "", "86.5", "74.8", "", "54.7", "", "2", "", "", "201", "1", "1", "148", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.9", "88.8", "", "", "", "", "88.3"]} -{"pcdb_id": 8993, "brand_name": "Trianco", "model_name": "Eurostar", "model_qualifier": "Utility 70/90", "winter_efficiency_pct": 86.5, "summer_efficiency_pct": 74.8, "comparative_hot_water_efficiency_pct": 54.7, "output_kw_max": 26.3, "final_year_of_manufacture": 2007, "raw": ["008993", "000062", "0", "2012/Mar/27 10:12", "Trianco Redfyre", "Trianco", "Eurostar", "Utility 70/90", "13961/2", "1997", "2007", "4", "1", "2", "1", "0", "", "", "1", "1", "1", "20.5", "26.3", "", "", "86.5", "74.8", "", "54.7", "", "2", "", "", "201", "1", "1", "148", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.9", "88.8", "", "", "", "", "88.3"]} -{"pcdb_id": 8994, "brand_name": "Trianco", "model_name": "Eurostar", "model_qualifier": "Combi 65", "winter_efficiency_pct": 84.1, "summer_efficiency_pct": 76.0, "comparative_hot_water_efficiency_pct": 45.3, "output_kw_max": 19.0, "final_year_of_manufacture": 2007, "raw": ["008994", "000062", "0", "2024/Jan/31 10:17", "Trianco Redfyre", "Trianco", "Eurostar", "Combi 65", "C16496/1", "2002", "2007", "4", "1", "1", "2", "0", "", "", "1", "2", "2", "14.7", "19.0", "", "", "84.1", "76.0", "", "45.3", "", "2", "", "", "203", "1", "1", "1.2", "5.5", "2", "1", "0", "63", "0", "25", "2", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.9", "86.1", "", "", "", "", "86.1"]} -{"pcdb_id": 8995, "brand_name": "Trianco", "model_name": "Eurostar", "model_qualifier": "Combi 50", "winter_efficiency_pct": 84.1, "summer_efficiency_pct": 76.0, "comparative_hot_water_efficiency_pct": 45.3, "output_kw_max": 19.0, "final_year_of_manufacture": 2002, "raw": ["008995", "000062", "0", "2024/Jan/31 10:17", "Trianco Redfyre", "Trianco", "Eurostar", "Combi 50", "C16496/1", "2002", "2002", "4", "1", "1", "2", "0", "", "", "1", "2", "2", "14.7", "19", "", "", "84.1", "76.0", "", "45.3", "", "2", "", "", "203", "1", "1", "1.2", "5.5", "2", "1", "0", "63", "0", "25", "2", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.9", "86.1", "", "", "", "", "86.1"]} -{"pcdb_id": 8996, "brand_name": "Trianco", "model_name": "Eurostar", "model_qualifier": "2000 50/65", "winter_efficiency_pct": 86.0, "summer_efficiency_pct": 74.3, "comparative_hot_water_efficiency_pct": 54.3, "output_kw_max": 19.0, "final_year_of_manufacture": 2007, "raw": ["008996", "000062", "0", "2012/Mar/27 10:12", "Trianco Redfyre", "Trianco", "Eurostar", "2000 50/65", "C16496/1", "2002", "2007", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "14.7", "19.0", "", "", "86.0", "74.3", "", "54.3", "", "2", "", "", "201", "1", "1", "70", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.9", "86.1", "", "", "", "", "86.1"]} -{"pcdb_id": 8997, "brand_name": "Trianco", "model_name": "Eurostar", "model_qualifier": "Utility 50/65 C16496/1", "winter_efficiency_pct": 86.0, "summer_efficiency_pct": 74.3, "comparative_hot_water_efficiency_pct": 54.3, "output_kw_max": 19.0, "final_year_of_manufacture": 2007, "raw": ["008997", "000062", "0", "2012/Mar/27 10:12", "Trianco Redfyre", "Trianco", "Eurostar", "Utility 50/65 C16496/1", "", "2002", "2007", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "14.7", "19.0", "", "", "86.0", "74.3", "", "54.3", "", "2", "", "", "201", "1", "1", "70", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.9", "86.1", "", "", "", "", "86.1"]} -{"pcdb_id": 8998, "brand_name": "Trianco", "model_name": "Eurostar", "model_qualifier": "External 95/115", "winter_efficiency_pct": 85.6, "summer_efficiency_pct": 73.9, "comparative_hot_water_efficiency_pct": 54.0, "output_kw_max": 33.7, "final_year_of_manufacture": 2007, "raw": ["008998", "000062", "0", "2012/Mar/27 10:12", "Trianco Redfyre", "Trianco", "Eurostar", "External 95/115", "C16880/1", "2000", "2007", "4", "1", "2", "1", "0", "", "", "1", "1", "2", "27.8", "33.7", "", "", "85.6", "73.9", "", "54.0", "", "2", "", "", "201", "1", "1", "90", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "84.8", "86.4", "", "", "", "", "86.1"]} -{"pcdb_id": 8999, "brand_name": "Trianco", "model_name": "Eurostar", "model_qualifier": "Utility 130/150", "winter_efficiency_pct": 85.6, "summer_efficiency_pct": 73.9, "comparative_hot_water_efficiency_pct": 54.0, "output_kw_max": 44.0, "final_year_of_manufacture": 2007, "raw": ["008999", "000062", "0", "2012/Mar/27 10:12", "Trianco Redfyre", "Trianco", "Eurostar", "Utility 130/150", "C16881/1", "2001", "2007", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "38.1", "44.0", "", "", "85.6", "73.9", "", "54.0", "", "2", "", "", "201", "1", "1", "90", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "84.7", "86.6", "", "", "", "", "86.2"]} -{"pcdb_id": 9000, "brand_name": "Trianco", "model_name": "Eurostar", "model_qualifier": "Internal 50/70 wm", "winter_efficiency_pct": 85.6, "summer_efficiency_pct": 73.9, "comparative_hot_water_efficiency_pct": 54.0, "output_kw_max": 20.5, "final_year_of_manufacture": 2007, "raw": ["009000", "000062", "0", "2012/Mar/27 10:12", "Trianco Redfyre", "Trianco", "Eurostar", "Internal 50/70 wm", "C16495/1", "2001", "2007", "4", "2", "1", "1", "0", "", "", "1", "1", "2", "14.65", "20.5", "", "", "85.6", "73.9", "", "54.0", "", "2", "", "", "201", "1", "1", "70", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.4", "85.9", "", "", "", "", "85.8"]} -{"pcdb_id": 9001, "brand_name": "Trianco", "model_name": "Iona", "model_qualifier": "50/70 wm", "winter_efficiency_pct": 85.6, "summer_efficiency_pct": 73.9, "comparative_hot_water_efficiency_pct": 54.0, "output_kw_max": 20.5, "final_year_of_manufacture": null, "raw": ["009001", "000062", "0", "2012/Mar/27 10:12", "Trianco Redfyre", "Trianco", "Iona", "50/70 wm", "C16495/1", "2001", "current", "4", "2", "1", "1", "0", "", "", "1", "1", "2", "14.65", "20.5", "", "", "85.6", "73.9", "", "54.0", "", "2", "", "", "201", "1", "1", "70", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.4", "85.9", "", "", "", "", "85.8"]} -{"pcdb_id": 9002, "brand_name": "Firebird", "model_name": "Popular", "model_qualifier": "150-200", "winter_efficiency_pct": 86.4, "summer_efficiency_pct": 74.7, "comparative_hot_water_efficiency_pct": 54.6, "output_kw_max": 58.61, "final_year_of_manufacture": 2013, "raw": ["009002", "000047", "0", "2018/Jan/03 12:36", "Firebird Boilers", "Firebird", "Popular", "150-200", "", "", "2013", "4", "1", "1", "1", "0", "", "", "1", "2", "1", "43.96", "58.61", "", "", "86.4", "74.7", "", "54.6", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.1", "86.7", "", "", "", "", "86.6"]} -{"pcdb_id": 9004, "brand_name": "Firebird", "model_name": "Boilerhouse S", "model_qualifier": "150-200", "winter_efficiency_pct": 86.4, "summer_efficiency_pct": 74.7, "comparative_hot_water_efficiency_pct": 54.6, "output_kw_max": 58.61, "final_year_of_manufacture": 2013, "raw": ["009004", "000047", "0", "2018/Jan/03 12:34", "Firebird Boilers", "Firebird", "Boilerhouse S", "150-200", "", "", "2013", "4", "1", "1", "1", "0", "", "", "1", "2", "1", "43.96", "58.61", "", "", "86.4", "74.7", "", "54.6", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.1", "86.7", "", "", "", "", "86.6"]} -{"pcdb_id": 9005, "brand_name": "Firebird", "model_name": "S (White Cased)", "model_qualifier": "150-200", "winter_efficiency_pct": 86.4, "summer_efficiency_pct": 74.7, "comparative_hot_water_efficiency_pct": 54.6, "output_kw_max": 58.61, "final_year_of_manufacture": 2013, "raw": ["009005", "000047", "0", "2018/Jan/03 12:33", "Firebird Boilers", "Firebird", "S (White Cased)", "150-200", "", "", "2013", "4", "1", "1", "1", "0", "", "", "1", "2", "1", "43.96", "58.61", "", "", "86.4", "74.7", "", "54.6", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.1", "86.7", "", "", "", "", "86.6"]} -{"pcdb_id": 9006, "brand_name": "Firebird", "model_name": "Heatpac", "model_qualifier": "150-200", "winter_efficiency_pct": 86.4, "summer_efficiency_pct": 74.7, "comparative_hot_water_efficiency_pct": 54.6, "output_kw_max": 58.61, "final_year_of_manufacture": 2013, "raw": ["009006", "000047", "0", "2018/Jan/03 12:31", "Firebird Boilers", "Firebird", "Heatpac", "150-200", "", "", "2013", "4", "1", "2", "1", "0", "", "", "1", "1", "1", "43.96", "58.61", "", "", "86.4", "74.7", "", "54.6", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.1", "86.7", "", "", "", "", "86.6"]} -{"pcdb_id": 9007, "brand_name": "Firebird", "model_name": "Popular", "model_qualifier": "200-250", "winter_efficiency_pct": 86.2, "summer_efficiency_pct": 74.5, "comparative_hot_water_efficiency_pct": 54.4, "output_kw_max": null, "final_year_of_manufacture": 2013, "raw": ["009007", "000047", "0", "2018/Jan/03 13:12", "Firebird Boilers", "Firebird", "Popular", "200-250", "", "", "2013", "4", "1", "1", "1", "0", "", "", "1", "2", "1", "58.61", ">70kW", "", "", "86.2", "74.5", "", "54.4", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.5", "86.9", "", "", "", "", "86.6"]} -{"pcdb_id": 9008, "brand_name": "Firebird", "model_name": "Heatpac", "model_qualifier": "200-250", "winter_efficiency_pct": 86.2, "summer_efficiency_pct": 74.5, "comparative_hot_water_efficiency_pct": 54.4, "output_kw_max": null, "final_year_of_manufacture": 2013, "raw": ["009008", "000047", "0", "2018/Jan/03 13:13", "Firebird Boilers", "Firebird", "Heatpac", "200-250", "", "", "2013", "4", "1", "2", "1", "0", "", "", "1", "1", "1", "58.61", ">70kW", "", "", "86.2", "74.5", "", "54.4", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.5", "86.9", "", "", "", "", "86.6"]} -{"pcdb_id": 9009, "brand_name": "Firebird", "model_name": "Boilerhouse S", "model_qualifier": "200-250", "winter_efficiency_pct": 86.2, "summer_efficiency_pct": 74.5, "comparative_hot_water_efficiency_pct": 54.4, "output_kw_max": null, "final_year_of_manufacture": 2013, "raw": ["009009", "000047", "0", "2018/Jan/03 13:14", "Firebird Boilers", "Firebird", "Boilerhouse S", "200-250", "", "", "2013", "4", "1", "1", "1", "0", "", "", "1", "2", "1", "58.61", ">70kW", "", "", "86.2", "74.5", "", "54.4", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.5", "86.9", "", "", "", "", "86.6"]} -{"pcdb_id": 9010, "brand_name": "Firebird", "model_name": "S (White Cased)", "model_qualifier": "200-250", "winter_efficiency_pct": 86.2, "summer_efficiency_pct": 74.5, "comparative_hot_water_efficiency_pct": 54.4, "output_kw_max": null, "final_year_of_manufacture": 2013, "raw": ["009010", "000047", "0", "2018/Jan/03 13:14", "Firebird Boilers", "Firebird", "S (White Cased)", "200-250", "", "", "2013", "4", "1", "1", "1", "0", "", "", "1", "2", "1", "58.61", ">70kW", "", "", "86.2", "74.5", "", "54.4", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.5", "86.9", "", "", "", "", "86.6"]} -{"pcdb_id": 9015, "brand_name": "Vaillant", "model_name": "Ecomax", "model_qualifier": "613/2E", "winter_efficiency_pct": 89.3, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 13.5, "final_year_of_manufacture": 2010, "raw": ["009015", "000031", "0", "2012/Mar/27 10:12", "Vaillant", "Vaillant", "Ecomax", "613/2E", "VU GBV126/2 E-C", "2001", "2010", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "13.5", "13.5", "", "", "89.3", "80.3", "", "58.6", "", "2", "1", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "92.0", "98.7", "", "", "", "", "97.5"]} -{"pcdb_id": 9016, "brand_name": "Vaillant", "model_name": "Ecomax", "model_qualifier": "618/2E", "winter_efficiency_pct": 89.3, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 18.4, "final_year_of_manufacture": 2010, "raw": ["009016", "000031", "0", "2012/Mar/27 10:12", "Vaillant", "Vaillant", "Ecomax", "618/2E", "VU GB 196/2E-C", "2001", "2010", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "18.4", "18.4", "", "", "89.3", "80.3", "", "58.6", "", "2", "1", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "92.0", "98.8", "", "", "", "", "97.5"]} -{"pcdb_id": 9017, "brand_name": "Vaillant", "model_name": "Ecomax", "model_qualifier": "622/2E", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 22.4, "final_year_of_manufacture": 2010, "raw": ["009017", "000031", "0", "2012/Mar/27 10:12", "Vaillant", "Vaillant", "Ecomax", "622/2E", "VU GB 246/2E-C", "2001", "2010", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "22.4", "22.4", "", "", "89.2", "80.2", "", "58.6", "", "2", "1", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "92.0", "98.6", "", "", "", "", "97.4"]} -{"pcdb_id": 9018, "brand_name": "Vaillant", "model_name": "Ecomax", "model_qualifier": "824/2E", "winter_efficiency_pct": 89.3, "summer_efficiency_pct": 80.7, "comparative_hot_water_efficiency_pct": 56.7, "output_kw_max": 18.4, "final_year_of_manufacture": 2010, "raw": ["009018", "000031", "0", "2010/Jan/28 08:17", "Vaillant", "Vaillant", "Ecomax", "824/2E", "VUW 246/2E-C", "2001", "2010", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "18.4", "18.4", "", "", "89.3", "80.7", "", "56.7", "", "2", "1", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "92.0", "98.8", "", "", "", "", "97.5"]} -{"pcdb_id": 9019, "brand_name": "Vaillant", "model_name": "Ecomax", "model_qualifier": "828/2E", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 80.6, "comparative_hot_water_efficiency_pct": 56.7, "output_kw_max": 22.4, "final_year_of_manufacture": 2010, "raw": ["009019", "000031", "0", "2010/Jan/28 08:31", "Vaillant", "Vaillant", "Ecomax", "828/2E", "VUW 286/2E-C", "2001", "2010", "2", "2", "2", "2", "0", "", "", "2", "2", "2", "22.4", "22.4", "", "", "89.2", "80.6", "", "56.7", "", "2", "1", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "92.0", "98.6", "", "", "", "", "97.4"]} -{"pcdb_id": 9020, "brand_name": "Vaillant", "model_name": "Ecomax", "model_qualifier": "835/2 E", "winter_efficiency_pct": 89.5, "summer_efficiency_pct": 80.9, "comparative_hot_water_efficiency_pct": 56.9, "output_kw_max": 27.0, "final_year_of_manufacture": 2010, "raw": ["009020", "000031", "0", "2010/Jan/28 08:49", "Vaillant", "Vaillant", "Ecomax", "835/2 E", "VUW 356 - C", "2001", "2010", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "27.0", "27.0", "", "", "89.5", "80.9", "", "56.9", "", "2", "1", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "92.0", "99.3", "", "", "", "", "97.9"]} -{"pcdb_id": 9021, "brand_name": "Vaillant", "model_name": "Thermocompact", "model_qualifier": "615E", "winter_efficiency_pct": 81.8, "summer_efficiency_pct": 71.1, "comparative_hot_water_efficiency_pct": 51.9, "output_kw_max": 15.0, "final_year_of_manufacture": 2010, "raw": ["009021", "000031", "0", "2012/Mar/27 10:12", "Vaillant", "Vaillant", "Thermocompact", "615E", "VU GB 152-5E", "2000", "2010", "2", "2", "1", "1", "0", "", "", "1", "2", "2", "15", "15", "", "", "81.8", "71.1", "", "51.9", "", "2", "1", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "83.5", "82.1", "", "", "", "", "82.3"]} -{"pcdb_id": 9022, "brand_name": "Vaillant", "model_name": "Thermocompact", "model_qualifier": "620E", "winter_efficiency_pct": 82.5, "summer_efficiency_pct": 71.8, "comparative_hot_water_efficiency_pct": 52.5, "output_kw_max": 20.0, "final_year_of_manufacture": 2010, "raw": ["009022", "000031", "0", "2012/Mar/27 10:12", "Vaillant", "Vaillant", "Thermocompact", "620E", "VU GB 202-5E", "2000", "2010", "2", "2", "1", "1", "0", "", "", "1", "2", "2", "20.0", "20.0", "", "", "82.5", "71.8", "", "52.5", "", "2", "1", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "83.4", "83.6", "", "", "", "", "83.6"]} -{"pcdb_id": 9023, "brand_name": "Vaillant", "model_name": "Thermocompact", "model_qualifier": "624 E", "winter_efficiency_pct": 82.5, "summer_efficiency_pct": 71.8, "comparative_hot_water_efficiency_pct": 52.4, "output_kw_max": 24.0, "final_year_of_manufacture": 2010, "raw": ["009023", "000031", "0", "2012/Mar/27 10:12", "Vaillant", "Vaillant", "Thermocompact", "624 E", "VU GB 242-5E", "2000", "2010", "2", "2", "1", "1", "0", "", "", "1", "2", "2", "24", "24", "", "", "82.5", "71.8", "", "52.4", "", "2", "1", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "83.2", "84.0", "", "", "", "", "83.8"]} -{"pcdb_id": 9024, "brand_name": "Vaillant", "model_name": "Thermocompact", "model_qualifier": "628E", "winter_efficiency_pct": 82.6, "summer_efficiency_pct": 71.9, "comparative_hot_water_efficiency_pct": 52.5, "output_kw_max": 28.0, "final_year_of_manufacture": 2010, "raw": ["009024", "000031", "0", "2012/Mar/27 10:12", "Vaillant", "Vaillant", "Thermocompact", "628E", "VU GB 282-5E", "2000", "2010", "2", "2", "1", "1", "0", "", "", "1", "2", "2", "28", "28", "", "", "82.6", "71.9", "", "52.5", "", "2", "1", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "83.4", "83.8", "", "", "", "", "83.7"]} -{"pcdb_id": 9025, "brand_name": "Vaillant", "model_name": "Turbomax Plus", "model_qualifier": "824E", "winter_efficiency_pct": 82.3, "summer_efficiency_pct": 72.2, "comparative_hot_water_efficiency_pct": 50.8, "output_kw_max": 24.0, "final_year_of_manufacture": 2010, "raw": ["009025", "000031", "0", "2010/Jan/28 08:50", "Vaillant", "Vaillant", "Turbomax Plus", "824E", "VUW GB 242-5E", "2000", "2010", "2", "2", "1", "2", "0", "", "", "1", "2", "2", "24", "24", "", "", "82.3", "72.2", "", "50.8", "", "2", "1", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "83.2", "84.0", "", "", "", "", "83.8"]} -{"pcdb_id": 9026, "brand_name": "Vaillant", "model_name": "Turbomax Plus", "model_qualifier": "828E", "winter_efficiency_pct": 82.4, "summer_efficiency_pct": 72.3, "comparative_hot_water_efficiency_pct": 50.8, "output_kw_max": 28.0, "final_year_of_manufacture": 2010, "raw": ["009026", "000031", "0", "2010/Jan/28 08:49", "Vaillant", "Vaillant", "Turbomax Plus", "828E", "VUW GB 282-5E", "2000", "2010", "2", "2", "1", "2", "0", "", "", "1", "2", "2", "28", "28", "", "", "82.4", "72.3", "", "50.8", "", "2", "1", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "83.4", "83.8", "", "", "", "", "83.7"]} -{"pcdb_id": 9027, "brand_name": "Vaillant", "model_name": "Turbomax Plus", "model_qualifier": "28E", "winter_efficiency_pct": 82.4, "summer_efficiency_pct": 72.3, "comparative_hot_water_efficiency_pct": 50.8, "output_kw_max": 28.0, "final_year_of_manufacture": 2010, "raw": ["009027", "000031", "0", "2010/Jan/28 08:50", "Vaillant", "Vaillant", "Turbomax Plus", "28E", "VUW GB 282-3E", "2000", "2010", "2", "2", "1", "2", "0", "", "", "1", "2", "2", "28", "28", "", "", "82.4", "72.3", "", "50.8", "", "2", "1", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "83.4", "83.8", "", "", "", "", "83.7"]} -{"pcdb_id": 9028, "brand_name": "Firebird", "model_name": "Popular", "model_qualifier": "90-120", "winter_efficiency_pct": 86.4, "summer_efficiency_pct": 74.7, "comparative_hot_water_efficiency_pct": 54.6, "output_kw_max": 35.17, "final_year_of_manufacture": 2013, "raw": ["009028", "000047", "0", "2018/Jan/03 12:42", "Firebird Boilers", "Firebird", "Popular", "90-120", "", "", "2013", "4", "1", "1", "1", "0", "", "", "1", "2", "1", "26.38", "35.17", "", "", "86.4", "74.7", "", "54.6", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.4", "86.7", "", "", "", "", "86.6"]} -{"pcdb_id": 9029, "brand_name": "Firebird", "model_name": "Heatpac", "model_qualifier": "90-120", "winter_efficiency_pct": 86.4, "summer_efficiency_pct": 74.7, "comparative_hot_water_efficiency_pct": 54.6, "output_kw_max": 35.17, "final_year_of_manufacture": 2013, "raw": ["009029", "000047", "0", "2018/Jan/03 12:42", "Firebird Boilers", "Firebird", "Heatpac", "90-120", "", "", "2013", "4", "1", "2", "1", "0", "", "", "1", "1", "1", "26.38", "35.17", "", "", "86.4", "74.7", "", "54.6", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.4", "86.7", "", "", "", "", "86.6"]} -{"pcdb_id": 9030, "brand_name": "Firebird", "model_name": "S (White cased)", "model_qualifier": "90-120", "winter_efficiency_pct": 86.4, "summer_efficiency_pct": 74.7, "comparative_hot_water_efficiency_pct": 54.6, "output_kw_max": 35.17, "final_year_of_manufacture": 2013, "raw": ["009030", "000047", "0", "2018/Jan/03 12:43", "Firebird Boilers", "Firebird", "S (White cased)", "90-120", "", "", "2013", "4", "1", "1", "1", "0", "", "", "1", "2", "1", "26.38", "35.17", "", "", "86.4", "74.7", "", "54.6", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.4", "86.7", "", "", "", "", "86.6"]} -{"pcdb_id": 9031, "brand_name": "Firebird", "model_name": "Roomsealed Popular (Hideaway)", "model_qualifier": "90-120", "winter_efficiency_pct": 86.4, "summer_efficiency_pct": 74.7, "comparative_hot_water_efficiency_pct": 54.6, "output_kw_max": 35.17, "final_year_of_manufacture": 2010, "raw": ["009031", "000047", "0", "2012/Mar/27 10:12", "Firebird Boilers", "Firebird", "Roomsealed Popular (Hideaway)", "90-120", "", "", "2010", "4", "1", "1", "1", "0", "", "", "1", "2", "1", "26.38", "35.17", "", "", "86.4", "74.7", "", "54.6", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.4", "86.7", "", "", "", "", "86.6"]} -{"pcdb_id": 9032, "brand_name": "Firebird", "model_name": "Boilerhouse S", "model_qualifier": "90-120", "winter_efficiency_pct": 86.4, "summer_efficiency_pct": 74.7, "comparative_hot_water_efficiency_pct": 54.6, "output_kw_max": 35.17, "final_year_of_manufacture": 2013, "raw": ["009032", "000047", "0", "2018/Jan/03 12:40", "Firebird Boilers", "Firebird", "Boilerhouse S", "90-120", "", "", "2013", "4", "1", "1", "1", "0", "", "", "1", "2", "1", "26.38", "35.17", "", "", "86.4", "74.7", "", "54.6", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.4", "86.7", "", "", "", "", "86.6"]} -{"pcdb_id": 9033, "brand_name": "Firebird", "model_name": "Heatpac S", "model_qualifier": "90-120", "winter_efficiency_pct": 86.4, "summer_efficiency_pct": 74.7, "comparative_hot_water_efficiency_pct": 54.6, "output_kw_max": 35.17, "final_year_of_manufacture": 2013, "raw": ["009033", "000047", "0", "2018/Jan/03 12:39", "Firebird Boilers", "Firebird", "Heatpac S", "90-120", "", "", "2013", "4", "1", "2", "1", "0", "", "", "1", "1", "1", "26.38", "35.17", "", "", "86.4", "74.7", "", "54.6", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.4", "86.7", "", "", "", "", "86.6"]} -{"pcdb_id": 9034, "brand_name": "Worcester", "model_name": "28 CDi - L", "model_qualifier": "RSF", "winter_efficiency_pct": 81.6, "summer_efficiency_pct": 71.5, "comparative_hot_water_efficiency_pct": 50.2, "output_kw_max": 24.0, "final_year_of_manufacture": 2005, "raw": ["009034", "000035", "0", "2020/Sep/04 08:02", "Worcester Heat Systems", "Worcester", "28 CDi - L", "RSF", "47 311 35", "1997", "2005", "2", "2", "1", "2", "0", "", "", "1", "2", "2", "24", "24", "", "", "81.6", "71.5", "", "50.2", "", "2", "1", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "84.0", "81.5", "", "", "", "", "82.0"]} -{"pcdb_id": 9036, "brand_name": "DD Heating", "model_name": "Heatline", "model_qualifier": "Star 24", "winter_efficiency_pct": 79.5, "summer_efficiency_pct": 69.4, "comparative_hot_water_efficiency_pct": 48.8, "output_kw_max": 23.17, "final_year_of_manufacture": 2004, "raw": ["009036", "000215", "0", "2011/Aug/31 10:31", "Turk Demir Dokum Fab AS", "DD Heating", "Heatline", "Star 24", "GC No. 47-157-01", "2001", "2004", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "23.17", "23.17", "", "", "79.5", "69.4", "", "48.8", "", "2", "", "", "104", "1", "2", "170", "17", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.5", "79.8", "", "", "", "", "80.2"]} -{"pcdb_id": 9037, "brand_name": "HRM Boilers", "model_name": "Wallstar 25/19", "model_qualifier": "20", "winter_efficiency_pct": 84.2, "summer_efficiency_pct": 76.1, "comparative_hot_water_efficiency_pct": 42.3, "output_kw_max": 25.4, "final_year_of_manufacture": null, "raw": ["009037", "000098", "0", "2024/Jan/31 10:17", "HRM Boilers", "HRM Boilers", "Wallstar 25/19", "20", "20020308", "2002", "current", "4", "2", "1", "2", "0", "", "", "1", "2", "2", "19", "25.4", "", "", "84.2", "76.1", "", "42.3", "", "2", "", "", "203", "1", "1", "140", "0", "1", "2", "0", "32.5", "0", "25", "1", "82", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.5", "86.4", "", "", "", "", "86.2"]} -{"pcdb_id": 9038, "brand_name": "Sime", "model_name": "Planet Super 4 F.S.", "model_qualifier": "", "winter_efficiency_pct": 81.3, "summer_efficiency_pct": 72.2, "comparative_hot_water_efficiency_pct": 37.6, "output_kw_max": 29.0, "final_year_of_manufacture": 2018, "raw": ["009038", "000213", "0", "2024/Jan/31 10:17", "Fonderie Sime S.p.A.", "Sime", "Planet Super 4 F.S.", "", "", "2002", "2018", "1", "1", "1", "2", "0", "", "", "1", "2", "2", "29.0", "29.0", "", "", "81.3", "72.2", "", "37.6", "", "2", "", "", "106", "1", "2", "180", "", "2", "1", "0", "62.8", "0", "16", "2", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.7", "81.6", "", "", "", "", "81.8"]} -{"pcdb_id": 9039, "brand_name": "Chaffoteaux et Maury", "model_name": "Centora Green 18-24", "model_qualifier": "Eurocondens 18-24", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 56.4, "output_kw_max": 24.0, "final_year_of_manufacture": 2002, "raw": ["009039", "000010", "0", "2006/Jan/17 12:55", "Chaffoteaux et Maury", "Chaffoteaux et Maury", "Centora Green 18-24", "Eurocondens 18-24", "", "2002", "2002", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.0", "24.0", "", "", "88.8", "80.2", "", "56.4", "", "2", "", "", "104", "1", "2", "150", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.8", "98.6", "", "", "", "", "96.7"]} -{"pcdb_id": 9041, "brand_name": "Chaffoteaux et Maury", "model_name": "Britony System 100", "model_qualifier": "", "winter_efficiency_pct": 79.5, "summer_efficiency_pct": 68.8, "comparative_hot_water_efficiency_pct": 50.3, "output_kw_max": 28.0, "final_year_of_manufacture": 2003, "raw": ["009041", "000010", "0", "2012/Mar/27 10:12", "Chaffoteaux et Maury", "Chaffoteaux et Maury", "Britony System 100", "", "", "1998", "2003", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "28", "28", "", "", "79.5", "68.8", "", "50.3", "", "2", "", "", "102", "1", "2", "150", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.5", "78.5", "", "", "", "", "79.2"]} -{"pcdb_id": 9042, "brand_name": "Chaffoteaux et Maury", "model_name": "Britony System 60", "model_qualifier": "", "winter_efficiency_pct": 79.9, "summer_efficiency_pct": 69.2, "comparative_hot_water_efficiency_pct": 50.6, "output_kw_max": 18.0, "final_year_of_manufacture": 2002, "raw": ["009042", "000010", "0", "2012/Mar/27 10:12", "Chaffoteaux et Maury", "Chaffoteaux et Maury", "Britony System 60", "", "", "2001", "2002", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "18", "18", "", "", "79.9", "69.2", "", "50.6", "", "2", "", "", "102", "1", "2", "150", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.6", "79.2", "", "", "", "", "79.8"]} -{"pcdb_id": 9043, "brand_name": "Chaffoteaux et Maury", "model_name": "Calydra 80 V2", "model_qualifier": "", "winter_efficiency_pct": 79.6, "summer_efficiency_pct": 69.5, "comparative_hot_water_efficiency_pct": 48.9, "output_kw_max": 24.0, "final_year_of_manufacture": 2003, "raw": ["009043", "000010", "0", "2006/Jan/17 12:55", "Chaffoteaux et Maury", "Chaffoteaux et Maury", "Calydra 80 V2", "", "GC No 47.980.20", "2002", "2003", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "24.0", "24.0", "", "", "79.6", "69.5", "", "48.9", "", "2", "", "", "104", "1", "2", "150", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.6", "78.9", "", "", "", "", "79.6"]} -{"pcdb_id": 9044, "brand_name": "GAH Heating Products", "model_name": "Thermecon 40/60", "model_qualifier": "Select C/F", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 18.2, "final_year_of_manufacture": null, "raw": ["009044", "000051", "0", "2012/Mar/27 10:12", "GAH Heating Products", "GAH Heating Products", "Thermecon 40/60", "Select C/F", "BFS40/60", "2002", "current", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "11.7", "18.2", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "88.2", "88.3", "", "", "", "", "88.2"]} -{"pcdb_id": 9045, "brand_name": "GAH Heating Products", "model_name": "Thermecon 40/60", "model_qualifier": "Option B/F", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 18.2, "final_year_of_manufacture": null, "raw": ["009045", "000051", "0", "2012/Mar/27 10:12", "GAH Heating Products", "GAH Heating Products", "Thermecon 40/60", "Option B/F", "BFO40/60", "2002", "current", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "11.7", "18.2", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "88.2", "88.3", "", "", "", "", "88.2"]} -{"pcdb_id": 9046, "brand_name": "GAH Heating Products", "model_name": "Thermecon 40/60", "model_qualifier": "Option C/F", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 18.2, "final_year_of_manufacture": null, "raw": ["009046", "000051", "0", "2012/Mar/27 10:12", "GAH Heating Products", "GAH Heating Products", "Thermecon 40/60", "Option C/F", "BFO40/60", "2002", "current", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "11.7", "18.2", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "88.2", "88.3", "", "", "", "", "88.2"]} -{"pcdb_id": 9047, "brand_name": "GAH Heating Products", "model_name": "Thermecon 40/60", "model_qualifier": "Select B/F", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 18.2, "final_year_of_manufacture": null, "raw": ["009047", "000051", "0", "2012/Mar/27 10:12", "GAH Heating Products", "GAH Heating Products", "Thermecon 40/60", "Select B/F", "BFS40/60", "2002", "current", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "11.7", "18.2", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "88.2", "88.3", "", "", "", "", "88.2"]} -{"pcdb_id": 9048, "brand_name": "GAH Heating Products", "model_name": "Thermecon 60/80", "model_qualifier": "System B/F", "winter_efficiency_pct": 85.5, "summer_efficiency_pct": 73.8, "comparative_hot_water_efficiency_pct": 53.9, "output_kw_max": 23.4, "final_year_of_manufacture": null, "raw": ["009048", "000051", "0", "2012/Mar/27 10:12", "GAH Heating Products", "GAH Heating Products", "Thermecon 60/80", "System B/F", "BFSYS60/80", "2002", "current", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "18.2", "23.4", "", "", "85.5", "73.8", "", "53.9", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.0", "84.9", "", "", "", "", "85.1"]} -{"pcdb_id": 9049, "brand_name": "GAH Heating Products", "model_name": "Thermecon 60/80", "model_qualifier": "System C/F", "winter_efficiency_pct": 85.5, "summer_efficiency_pct": 73.8, "comparative_hot_water_efficiency_pct": 53.9, "output_kw_max": 23.4, "final_year_of_manufacture": null, "raw": ["009049", "000051", "0", "2012/Mar/27 10:12", "GAH Heating Products", "GAH Heating Products", "Thermecon 60/80", "System C/F", "CFSYS60/80", "2002", "current", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "18.2", "23.4", "", "", "85.5", "73.8", "", "53.9", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.0", "84.9", "", "", "", "", "85.1"]} -{"pcdb_id": 9050, "brand_name": "GAH Heating Products", "model_name": "Thermecon 60/80", "model_qualifier": "Select B/F", "winter_efficiency_pct": 85.5, "summer_efficiency_pct": 73.8, "comparative_hot_water_efficiency_pct": 53.9, "output_kw_max": 23.4, "final_year_of_manufacture": null, "raw": ["009050", "000051", "0", "2012/Mar/27 10:12", "GAH Heating Products", "GAH Heating Products", "Thermecon 60/80", "Select B/F", "BFS60/80", "2002", "current", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "18.2", "23.4", "", "", "85.5", "73.8", "", "53.9", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.0", "84.9", "", "", "", "", "85.1"]} -{"pcdb_id": 9051, "brand_name": "GAH Heating Products", "model_name": "Thermecon 60/80", "model_qualifier": "Select C/F", "winter_efficiency_pct": 85.5, "summer_efficiency_pct": 73.8, "comparative_hot_water_efficiency_pct": 53.9, "output_kw_max": 23.4, "final_year_of_manufacture": null, "raw": ["009051", "000051", "0", "2012/Mar/27 10:12", "GAH Heating Products", "GAH Heating Products", "Thermecon 60/80", "Select C/F", "CFS60/80", "2002", "current", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "18.2", "23.4", "", "", "85.5", "73.8", "", "53.9", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.0", "84.9", "", "", "", "", "85.1"]} -{"pcdb_id": 9052, "brand_name": "GAH Heating Products", "model_name": "Thermecon 60/80", "model_qualifier": "Option B/F", "winter_efficiency_pct": 85.5, "summer_efficiency_pct": 73.8, "comparative_hot_water_efficiency_pct": 53.9, "output_kw_max": 23.4, "final_year_of_manufacture": null, "raw": ["009052", "000051", "0", "2012/Mar/27 10:12", "GAH Heating Products", "GAH Heating Products", "Thermecon 60/80", "Option B/F", "BFO60/80", "2002", "current", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "18.2", "23.4", "", "", "85.5", "73.8", "", "53.9", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.0", "84.9", "", "", "", "", "85.1"]} -{"pcdb_id": 9053, "brand_name": "GAH Heating Products", "model_name": "Thermecon 60/80", "model_qualifier": "Option C/F", "winter_efficiency_pct": 85.5, "summer_efficiency_pct": 73.8, "comparative_hot_water_efficiency_pct": 53.9, "output_kw_max": 23.4, "final_year_of_manufacture": null, "raw": ["009053", "000051", "0", "2012/Mar/27 10:12", "GAH Heating Products", "GAH Heating Products", "Thermecon 60/80", "Option C/F", "CFO60/80", "2002", "current", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "18.2", "23.4", "", "", "85.5", "73.8", "", "53.9", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.0", "84.9", "", "", "", "", "85.1"]} -{"pcdb_id": 9054, "brand_name": "GAH Heating Products", "model_name": "Thermecon 80/95", "model_qualifier": "System B/F", "winter_efficiency_pct": 85.3, "summer_efficiency_pct": 73.6, "comparative_hot_water_efficiency_pct": 53.7, "output_kw_max": 27.8, "final_year_of_manufacture": null, "raw": ["009054", "000051", "0", "2012/Mar/27 10:12", "GAH Heating Products", "GAH Heating Products", "Thermecon 80/95", "System B/F", "BFSYS80/95", "2002", "current", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "23.4", "27.8", "", "", "85.3", "73.6", "", "53.7", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.6", "84.9", "", "", "", "", "85.0"]} -{"pcdb_id": 9055, "brand_name": "GAH Heating Products", "model_name": "Thermecon 80/95", "model_qualifier": "System C/F", "winter_efficiency_pct": 85.3, "summer_efficiency_pct": 73.6, "comparative_hot_water_efficiency_pct": 53.7, "output_kw_max": 27.8, "final_year_of_manufacture": null, "raw": ["009055", "000051", "0", "2012/Mar/27 10:12", "GAH Heating Products", "GAH Heating Products", "Thermecon 80/95", "System C/F", "CFSYS80/95", "2002", "current", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "23.4", "27.8", "", "", "85.3", "73.6", "", "53.7", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.6", "84.9", "", "", "", "", "85.0"]} -{"pcdb_id": 9056, "brand_name": "GAH Heating Products", "model_name": "Thermecon 80/95", "model_qualifier": "Select B/F", "winter_efficiency_pct": 85.3, "summer_efficiency_pct": 73.6, "comparative_hot_water_efficiency_pct": 53.7, "output_kw_max": 27.8, "final_year_of_manufacture": null, "raw": ["009056", "000051", "0", "2012/Mar/27 10:12", "GAH Heating Products", "GAH Heating Products", "Thermecon 80/95", "Select B/F", "BFS80/95", "2002", "current", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "23.4", "27.8", "", "", "85.3", "73.6", "", "53.7", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.6", "84.9", "", "", "", "", "85.0"]} -{"pcdb_id": 9057, "brand_name": "GAH Heating Products", "model_name": "Thermecon 80/95", "model_qualifier": "Select C/F", "winter_efficiency_pct": 85.3, "summer_efficiency_pct": 73.6, "comparative_hot_water_efficiency_pct": 53.7, "output_kw_max": 27.8, "final_year_of_manufacture": null, "raw": ["009057", "000051", "0", "2012/Mar/27 10:12", "GAH Heating Products", "GAH Heating Products", "Thermecon 80/95", "Select C/F", "CFS80/95", "2002", "current", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "23.4", "27.8", "", "", "85.3", "73.6", "", "53.7", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.6", "84.9", "", "", "", "", "85.0"]} -{"pcdb_id": 9058, "brand_name": "GAH Heating Products", "model_name": "Thermecon 80/95", "model_qualifier": "Option B/F", "winter_efficiency_pct": 85.3, "summer_efficiency_pct": 73.6, "comparative_hot_water_efficiency_pct": 53.7, "output_kw_max": 27.8, "final_year_of_manufacture": null, "raw": ["009058", "000051", "0", "2012/Mar/27 10:12", "GAH Heating Products", "GAH Heating Products", "Thermecon 80/95", "Option B/F", "BFO80/95", "2002", "current", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "23.4", "27.8", "", "", "85.3", "73.6", "", "53.7", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.6", "84.9", "", "", "", "", "85.0"]} -{"pcdb_id": 9059, "brand_name": "GAH Heating Products", "model_name": "Thermecon 80/95", "model_qualifier": "Option C/F", "winter_efficiency_pct": 85.3, "summer_efficiency_pct": 73.6, "comparative_hot_water_efficiency_pct": 53.7, "output_kw_max": 27.8, "final_year_of_manufacture": null, "raw": ["009059", "000051", "0", "2012/Mar/27 10:12", "GAH Heating Products", "GAH Heating Products", "Thermecon 80/95", "Option C/F", "CFO80/95", "2002", "current", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "23.4", "27.8", "", "", "85.3", "73.6", "", "53.7", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.6", "84.9", "", "", "", "", "85.0"]} -{"pcdb_id": 9060, "brand_name": "GAH Heating Products", "model_name": "Thermecon 90/120", "model_qualifier": "System B/F", "winter_efficiency_pct": 85.0, "summer_efficiency_pct": 73.3, "comparative_hot_water_efficiency_pct": 53.6, "output_kw_max": 35.2, "final_year_of_manufacture": null, "raw": ["009060", "000051", "0", "2012/Mar/27 10:12", "GAH Heating Products", "GAH Heating Products", "Thermecon 90/120", "System B/F", "BFSYS90/120", "2002", "current", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "26.4", "35.2", "", "", "85.0", "73.3", "", "53.6", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.3", "84.8", "", "", "", "", "84.9"]} -{"pcdb_id": 9061, "brand_name": "GAH Heating Products", "model_name": "Thermecon 90/120", "model_qualifier": "Select B/F", "winter_efficiency_pct": 85.0, "summer_efficiency_pct": 73.3, "comparative_hot_water_efficiency_pct": 53.6, "output_kw_max": 35.2, "final_year_of_manufacture": null, "raw": ["009061", "000051", "0", "2012/Mar/27 10:12", "GAH Heating Products", "GAH Heating Products", "Thermecon 90/120", "Select B/F", "BFS90/120", "2002", "current", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "26.4", "35.2", "", "", "85.0", "73.3", "", "53.6", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.3", "84.8", "", "", "", "", "84.9"]} -{"pcdb_id": 9062, "brand_name": "GAH Heating Products", "model_name": "Thermecon 90/120", "model_qualifier": "System C/F", "winter_efficiency_pct": 85.0, "summer_efficiency_pct": 73.3, "comparative_hot_water_efficiency_pct": 53.6, "output_kw_max": 35.2, "final_year_of_manufacture": null, "raw": ["009062", "000051", "0", "2012/Mar/27 10:12", "GAH Heating Products", "GAH Heating Products", "Thermecon 90/120", "System C/F", "CFSYS90/120", "2002", "current", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "26.4", "35.2", "", "", "85.0", "73.3", "", "53.6", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.3", "84.8", "", "", "", "", "84.9"]} -{"pcdb_id": 9063, "brand_name": "GAH Heating Products", "model_name": "Thermecon 90/120", "model_qualifier": "Select C/F", "winter_efficiency_pct": 85.0, "summer_efficiency_pct": 73.3, "comparative_hot_water_efficiency_pct": 53.6, "output_kw_max": 35.2, "final_year_of_manufacture": null, "raw": ["009063", "000051", "0", "2012/Mar/27 10:12", "GAH Heating Products", "GAH Heating Products", "Thermecon 90/120", "Select C/F", "CFS90/120", "2002", "current", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "26.4", "35.2", "", "", "85.0", "73.3", "", "53.6", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.3", "84.8", "", "", "", "", "84.9"]} -{"pcdb_id": 9064, "brand_name": "GAH Heating Products", "model_name": "Thermecon 90/120", "model_qualifier": "Option B/F", "winter_efficiency_pct": 85.0, "summer_efficiency_pct": 73.3, "comparative_hot_water_efficiency_pct": 53.6, "output_kw_max": 35.2, "final_year_of_manufacture": null, "raw": ["009064", "000051", "0", "2012/Mar/27 10:12", "GAH Heating Products", "GAH Heating Products", "Thermecon 90/120", "Option B/F", "BFO90/120", "2002", "current", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "26.4", "35.2", "", "", "85.0", "73.3", "", "53.6", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.3", "84.8", "", "", "", "", "84.9"]} -{"pcdb_id": 9065, "brand_name": "GAH Heating Products", "model_name": "Thermecon 90/120", "model_qualifier": "Option C/F", "winter_efficiency_pct": 85.0, "summer_efficiency_pct": 73.3, "comparative_hot_water_efficiency_pct": 53.6, "output_kw_max": 35.2, "final_year_of_manufacture": null, "raw": ["009065", "000051", "0", "2012/Mar/27 10:12", "GAH Heating Products", "GAH Heating Products", "Thermecon 90/120", "Option C/F", "CFO90/120", "2002", "current", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "26.4", "35.2", "", "", "85.0", "73.3", "", "53.6", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.3", "84.8", "", "", "", "", "84.9"]} -{"pcdb_id": 9066, "brand_name": "GAH Heating Products", "model_name": "Thermecon 100/150", "model_qualifier": "System B/F", "winter_efficiency_pct": 85.2, "summer_efficiency_pct": 73.5, "comparative_hot_water_efficiency_pct": 53.7, "output_kw_max": 43.9, "final_year_of_manufacture": null, "raw": ["009066", "000051", "0", "2012/Mar/27 10:12", "GAH Heating Products", "GAH Heating Products", "Thermecon 100/150", "System B/F", "BFSYS100/150", "2002", "current", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "29.3", "43.9", "", "", "85.2", "73.5", "", "53.7", "", "2", "", "", "201", "1", "1", "161", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.5", "84.9", "", "", "", "", "85.0"]} -{"pcdb_id": 9067, "brand_name": "GAH Heating Products", "model_name": "Thermecon 100/150", "model_qualifier": "System C/F", "winter_efficiency_pct": 85.2, "summer_efficiency_pct": 73.5, "comparative_hot_water_efficiency_pct": 53.7, "output_kw_max": 43.9, "final_year_of_manufacture": null, "raw": ["009067", "000051", "0", "2012/Mar/27 10:12", "GAH Heating Products", "GAH Heating Products", "Thermecon 100/150", "System C/F", "CFSYS100/150", "2002", "current", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "29.3", "43.9", "", "", "85.2", "73.5", "", "53.7", "", "2", "", "", "201", "1", "1", "161", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.5", "84.9", "", "", "", "", "85.0"]} -{"pcdb_id": 9068, "brand_name": "GAH Heating Products", "model_name": "Thermecon 100/150", "model_qualifier": "Option C/F", "winter_efficiency_pct": 85.2, "summer_efficiency_pct": 73.5, "comparative_hot_water_efficiency_pct": 53.7, "output_kw_max": 43.9, "final_year_of_manufacture": null, "raw": ["009068", "000051", "0", "2012/Mar/27 10:12", "GAH Heating Products", "GAH Heating Products", "Thermecon 100/150", "Option C/F", "CFO100/150", "2002", "current", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "29.3", "43.9", "", "", "85.2", "73.5", "", "53.7", "", "2", "", "", "201", "1", "1", "161", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.5", "84.9", "", "", "", "", "85.0"]} -{"pcdb_id": 9069, "brand_name": "GAH Heating Products", "model_name": "Thermecon 100/150", "model_qualifier": "Select B/F", "winter_efficiency_pct": 85.2, "summer_efficiency_pct": 73.5, "comparative_hot_water_efficiency_pct": 53.7, "output_kw_max": 43.9, "final_year_of_manufacture": null, "raw": ["009069", "000051", "0", "2012/Mar/27 10:12", "GAH Heating Products", "GAH Heating Products", "Thermecon 100/150", "Select B/F", "BFS100/150", "2002", "current", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "29.3", "43.9", "", "", "85.2", "73.5", "", "53.7", "", "2", "", "", "201", "1", "1", "161", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.5", "84.9", "", "", "", "", "85.0"]} -{"pcdb_id": 9070, "brand_name": "GAH Heating Products", "model_name": "Thermecon 100/150", "model_qualifier": "Select C/F", "winter_efficiency_pct": 85.2, "summer_efficiency_pct": 73.5, "comparative_hot_water_efficiency_pct": 53.7, "output_kw_max": 43.9, "final_year_of_manufacture": null, "raw": ["009070", "000051", "0", "2012/Mar/27 10:12", "GAH Heating Products", "GAH Heating Products", "Thermecon 100/150", "Select C/F", "CFS100/150", "2002", "current", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "29.3", "43.9", "", "", "85.2", "73.5", "", "53.7", "", "2", "", "", "201", "1", "1", "161", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.5", "84.9", "", "", "", "", "85.0"]} -{"pcdb_id": 9071, "brand_name": "GAH Heating Products", "model_name": "Thermecon 100/150", "model_qualifier": "Option B/F", "winter_efficiency_pct": 85.2, "summer_efficiency_pct": 73.5, "comparative_hot_water_efficiency_pct": 53.7, "output_kw_max": 43.9, "final_year_of_manufacture": null, "raw": ["009071", "000051", "0", "2012/Mar/27 10:12", "GAH Heating Products", "GAH Heating Products", "Thermecon 100/150", "Option B/F", "BFO100/150", "2002", "current", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "29.3", "43.9", "", "", "85.2", "73.5", "", "53.7", "", "2", "", "", "201", "1", "1", "161", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.5", "84.9", "", "", "", "", "85.0"]} -{"pcdb_id": 9072, "brand_name": "GAH Heating Products", "model_name": "Thermecon 140/190", "model_qualifier": "Select B/F", "winter_efficiency_pct": 85.0, "summer_efficiency_pct": 73.3, "comparative_hot_water_efficiency_pct": 53.6, "output_kw_max": 55.7, "final_year_of_manufacture": null, "raw": ["009072", "000051", "0", "2012/Mar/27 10:12", "GAH Heating Products", "GAH Heating Products", "Thermecon 140/190", "Select B/F", "BFS140/190", "2002", "current", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "41", "55.7", "", "", "85.0", "73.3", "", "53.6", "", "2", "", "", "201", "1", "1", "151", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.3", "84.8", "", "", "", "", "84.9"]} -{"pcdb_id": 9073, "brand_name": "GAH Heating Products", "model_name": "Thermecon 140/190", "model_qualifier": "Select C/F", "winter_efficiency_pct": 85.0, "summer_efficiency_pct": 73.3, "comparative_hot_water_efficiency_pct": 53.6, "output_kw_max": 55.7, "final_year_of_manufacture": null, "raw": ["009073", "000051", "0", "2012/Mar/27 10:12", "GAH Heating Products", "GAH Heating Products", "Thermecon 140/190", "Select C/F", "CFS140/190", "2002", "current", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "41", "55.7", "", "", "85.0", "73.3", "", "53.6", "", "2", "", "", "201", "1", "1", "151", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.3", "84.8", "", "", "", "", "84.9"]} -{"pcdb_id": 9074, "brand_name": "GAH Heating Products", "model_name": "Thermecon 140/190", "model_qualifier": "Option B/F", "winter_efficiency_pct": 85.0, "summer_efficiency_pct": 73.3, "comparative_hot_water_efficiency_pct": 53.6, "output_kw_max": 55.7, "final_year_of_manufacture": null, "raw": ["009074", "000051", "0", "2012/Mar/27 10:12", "GAH Heating Products", "GAH Heating Products", "Thermecon 140/190", "Option B/F", "BFO140/190", "2002", "current", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "41", "55.7", "", "", "85.0", "73.3", "", "53.6", "", "2", "", "", "201", "1", "1", "151", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.3", "84.8", "", "", "", "", "84.9"]} -{"pcdb_id": 9075, "brand_name": "GAH Heating Products", "model_name": "Thermecon 140/190", "model_qualifier": "Option C/F", "winter_efficiency_pct": 85.0, "summer_efficiency_pct": 73.3, "comparative_hot_water_efficiency_pct": 53.6, "output_kw_max": 55.7, "final_year_of_manufacture": null, "raw": ["009075", "000051", "0", "2012/Mar/27 10:12", "GAH Heating Products", "GAH Heating Products", "Thermecon 140/190", "Option C/F", "CFO140/190", "2002", "current", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "41", "55.7", "", "", "85.0", "73.3", "", "53.6", "", "2", "", "", "201", "1", "1", "151", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.3", "84.8", "", "", "", "", "84.9"]} -{"pcdb_id": 9076, "brand_name": "GAH Heating Products", "model_name": "Thermecon 190/240", "model_qualifier": "Select B/F", "winter_efficiency_pct": 85.5, "summer_efficiency_pct": 73.8, "comparative_hot_water_efficiency_pct": 53.9, "output_kw_max": null, "final_year_of_manufacture": null, "raw": ["009076", "000051", "0", "2012/Mar/27 10:12", "GAH Heating Products", "GAH Heating Products", "Thermecon 190/240", "Select B/F", "BFS190/240", "2002", "current", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "55.7", ">70kW", "", "", "85.5", "73.8", "", "53.9", "", "2", "", "", "201", "1", "1", "151", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.8", "84.9", "", "", "", "", "85.2"]} -{"pcdb_id": 9077, "brand_name": "GAH Heating Products", "model_name": "Thermecon 190/240", "model_qualifier": "Select C/F", "winter_efficiency_pct": 85.5, "summer_efficiency_pct": 73.8, "comparative_hot_water_efficiency_pct": 53.9, "output_kw_max": null, "final_year_of_manufacture": null, "raw": ["009077", "000051", "0", "2012/Mar/27 10:12", "GAH Heating Products", "GAH Heating Products", "Thermecon 190/240", "Select C/F", "CFS190/240", "2002", "current", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "55.7", ">70kW", "", "", "85.5", "73.8", "", "53.9", "", "2", "", "", "201", "1", "1", "151", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.8", "84.9", "", "", "", "", "85.2"]} -{"pcdb_id": 9078, "brand_name": "GAH Heating Products", "model_name": "Thermecon 190/240", "model_qualifier": "Option B/F", "winter_efficiency_pct": 85.5, "summer_efficiency_pct": 73.8, "comparative_hot_water_efficiency_pct": 53.9, "output_kw_max": null, "final_year_of_manufacture": null, "raw": ["009078", "000051", "0", "2012/Mar/27 10:12", "GAH Heating Products", "GAH Heating Products", "Thermecon 190/240", "Option B/F", "BFO190/240", "2002", "current", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "55.7", ">70kW", "", "", "85.5", "73.8", "", "53.9", "", "2", "", "", "201", "1", "1", "151", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.8", "84.9", "", "", "", "", "85.2"]} -{"pcdb_id": 9079, "brand_name": "GAH Heating Products", "model_name": "Thermecon 190/240", "model_qualifier": "Option C/F", "winter_efficiency_pct": 85.5, "summer_efficiency_pct": 73.8, "comparative_hot_water_efficiency_pct": 53.9, "output_kw_max": null, "final_year_of_manufacture": null, "raw": ["009079", "000051", "0", "2012/Mar/27 10:12", "GAH Heating Products", "GAH Heating Products", "Thermecon 190/240", "Option C/F", "CFO190/240", "2002", "current", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "55.7", ">70kW", "", "", "85.5", "73.8", "", "53.9", "", "2", "", "", "201", "1", "1", "151", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.8", "84.9", "", "", "", "", "85.2"]} -{"pcdb_id": 9084, "brand_name": "GAH Heating Products", "model_name": "Thermecon 40/50 W/M", "model_qualifier": "External", "winter_efficiency_pct": 86.1, "summer_efficiency_pct": 74.4, "comparative_hot_water_efficiency_pct": 54.4, "output_kw_max": 14.7, "final_year_of_manufacture": null, "raw": ["009084", "000051", "0", "2012/Mar/27 10:12", "GAH Heating Products", "GAH Heating Products", "Thermecon 40/50 W/M", "External", "WE40/50", "2002", "current", "4", "1", "2", "1", "0", "", "", "1", "2", "2", "11.7", "14.7", "", "", "86.1", "74.4", "", "54.4", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.8", "86.0", "", "", "", "", "86.2"]} -{"pcdb_id": 9085, "brand_name": "GAH Heating Products", "model_name": "Thermecon 40/50 W/M", "model_qualifier": "Internal B/F", "winter_efficiency_pct": 86.1, "summer_efficiency_pct": 74.4, "comparative_hot_water_efficiency_pct": 54.4, "output_kw_max": 14.7, "final_year_of_manufacture": null, "raw": ["009085", "000051", "0", "2012/Mar/27 10:12", "GAH Heating Products", "GAH Heating Products", "Thermecon 40/50 W/M", "Internal B/F", "BWI40/50", "2002", "current", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "11.7", "14.7", "", "", "86.1", "74.4", "", "54.4", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.8", "86.0", "", "", "", "", "86.2"]} -{"pcdb_id": 9086, "brand_name": "GAH Heating Products", "model_name": "Thermecon 40/50 W/M", "model_qualifier": "Internal C/F", "winter_efficiency_pct": 86.1, "summer_efficiency_pct": 74.4, "comparative_hot_water_efficiency_pct": 54.4, "output_kw_max": 14.7, "final_year_of_manufacture": null, "raw": ["009086", "000051", "0", "2012/Mar/27 10:12", "GAH Heating Products", "GAH Heating Products", "Thermecon 40/50 W/M", "Internal C/F", "CWI40/50", "2002", "current", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "11.7", "14.7", "", "", "86.1", "74.4", "", "54.4", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.8", "86.0", "", "", "", "", "86.2"]} -{"pcdb_id": 9087, "brand_name": "GAH Heating Products", "model_name": "Thermecon 50/80 W/M", "model_qualifier": "External", "winter_efficiency_pct": 85.8, "summer_efficiency_pct": 74.1, "comparative_hot_water_efficiency_pct": 54.1, "output_kw_max": 23.4, "final_year_of_manufacture": null, "raw": ["009087", "000051", "0", "2012/Mar/27 10:12", "GAH Heating Products", "GAH Heating Products", "Thermecon 50/80 W/M", "External", "WE50/80", "2002", "current", "4", "1", "2", "1", "0", "", "", "1", "2", "2", "14.7", "23.4", "", "", "85.8", "74.1", "", "54.1", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "88.4", "85.4", "", "", "", "", "85.9"]} -{"pcdb_id": 9088, "brand_name": "GAH Heating Products", "model_name": "Thermecon 50/80 W/M", "model_qualifier": "Internal C/F", "winter_efficiency_pct": 85.8, "summer_efficiency_pct": 74.1, "comparative_hot_water_efficiency_pct": 54.1, "output_kw_max": 23.4, "final_year_of_manufacture": null, "raw": ["009088", "000051", "0", "2012/Mar/27 10:12", "GAH Heating Products", "GAH Heating Products", "Thermecon 50/80 W/M", "Internal C/F", "CWI50/80", "2002", "current", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "14.7", "23.4", "", "", "85.8", "74.1", "", "54.1", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "88.4", "85.4", "", "", "", "", "85.9"]} -{"pcdb_id": 9089, "brand_name": "GAH Heating Products", "model_name": "Thermecon 50/80 W/M", "model_qualifier": "Internal B/F", "winter_efficiency_pct": 85.8, "summer_efficiency_pct": 74.1, "comparative_hot_water_efficiency_pct": 54.1, "output_kw_max": 23.4, "final_year_of_manufacture": null, "raw": ["009089", "000051", "0", "2012/Mar/27 10:12", "GAH Heating Products", "GAH Heating Products", "Thermecon 50/80 W/M", "Internal B/F", "BWI50/80", "2002", "current", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "14.7", "23.4", "", "", "85.8", "74.1", "", "54.1", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "88.4", "85.4", "", "", "", "", "85.9"]} -{"pcdb_id": 9091, "brand_name": "MHS Boilers", "model_name": "Strata Streamline", "model_qualifier": "31", "winter_efficiency_pct": 87.6, "summer_efficiency_pct": 78.6, "comparative_hot_water_efficiency_pct": 57.4, "output_kw_max": 29.0, "final_year_of_manufacture": null, "raw": ["009091", "000024", "0", "2012/Mar/27 10:12", "MHS Boilers", "MHS Boilers", "Strata Streamline", "31", "", "2000", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "29", "29", "", "", "87.6", "78.6", "", "57.4", "", "2", "", "", "102", "1", "2", "60", "6", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "86.7", "96.3", "", "", "", "", "94.5"]} -{"pcdb_id": 9095, "brand_name": "Boulter", "model_name": "Eco-System", "model_qualifier": "12/19", "winter_efficiency_pct": 86.6, "summer_efficiency_pct": 74.9, "comparative_hot_water_efficiency_pct": 54.7, "output_kw_max": 19.0, "final_year_of_manufacture": 2005, "raw": ["009095", "000041", "0", "2012/Mar/27 10:12", "Boulter Boilers", "Boulter", "Eco-System", "12/19", "", "2002", "2005", "4", "1", "1", "1", "0", "", "", "1", "3", "2", "12", "19", "", "", "86.6", "74.9", "", "54.7", "", "2", "", "", "201", "1", "1", "150", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.0", "87.0", "", "", "", "", "87.0"]} -{"pcdb_id": 9097, "brand_name": "Boulter", "model_name": "Eco-System", "model_qualifier": "19/26", "winter_efficiency_pct": 85.3, "summer_efficiency_pct": 73.6, "comparative_hot_water_efficiency_pct": 53.7, "output_kw_max": 26.0, "final_year_of_manufacture": 2005, "raw": ["009097", "000041", "0", "2012/Mar/27 10:12", "Boulter Boilers", "Boulter", "Eco-System", "19/26", "", "2002", "2005", "4", "1", "1", "1", "0", "", "", "1", "3", "2", "19", "26", "", "", "85.3", "73.6", "", "53.7", "", "2", "", "", "201", "1", "1", "150", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "84.8", "85.7", "", "", "", "", "85.6"]} -{"pcdb_id": 9098, "brand_name": "Sime", "model_name": "Friendly Format 80", "model_qualifier": "", "winter_efficiency_pct": 82.0, "summer_efficiency_pct": 71.9, "comparative_hot_water_efficiency_pct": 50.6, "output_kw_max": 23.7, "final_year_of_manufacture": 2018, "raw": ["009098", "000213", "0", "2018/Mar/05 14:09", "Fonderie Sime S.p.A.", "Sime", "Friendly Format 80", "", "LPG", "1998", "2018", "2", "2", "1", "2", "0", "", "", "1", "2", "2", "23.7", "23.7", "", "", "82.0", "71.9", "", "50.6", "", "2", "1", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "84.5", "81.9", "", "", "", "", "82.4"]} -{"pcdb_id": 9099, "brand_name": "Sime", "model_name": "Planet Dewy 110", "model_qualifier": "", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 56.3, "output_kw_max": 29.3, "final_year_of_manufacture": 2018, "raw": ["009099", "000213", "0", "2018/Mar/05 14:27", "Fonderie Sime S.p.A.", "Sime", "Planet Dewy 110", "", "LPG", "2000", "2018", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "29.3", "29.3", "", "", "88.7", "80.1", "", "56.3", "", "2", "1", "", "104", "1", "2", "175", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.0", "98.2", "", "", "", "", "96.6"]} -{"pcdb_id": 9100, "brand_name": "Sime", "model_name": "Planet Dewy 90", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 56.1, "output_kw_max": 24.0, "final_year_of_manufacture": 2018, "raw": ["009100", "000213", "0", "2018/Mar/05 14:30", "Fonderie Sime S.p.A.", "Sime", "Planet Dewy 90", "", "LPG", "2000", "2018", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24.0", "24.0", "", "", "88.4", "79.8", "", "56.1", "", "2", "1", "", "104", "1", "2", "175", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.0", "97.8", "", "", "", "", "96.1"]} -{"pcdb_id": 9101, "brand_name": "Sime", "model_name": "Format 100 C", "model_qualifier": "", "winter_efficiency_pct": 81.9, "summer_efficiency_pct": 71.8, "comparative_hot_water_efficiency_pct": 50.5, "output_kw_max": 28.8, "final_year_of_manufacture": 2018, "raw": ["009101", "000213", "0", "2018/Feb/26 16:58", "Fonderie Sime S.p.A.", "Sime", "Format 100 C", "", "LPG", "2001", "2018", "2", "2", "1", "2", "0", "", "", "1", "2", "2", "28.8", "28.8", "", "", "81.9", "71.8", "", "50.5", "", "2", "1", "", "104", "1", "2", "160", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "83.8", "82.3", "", "", "", "", "82.6"]} -{"pcdb_id": 9102, "brand_name": "Sime", "model_name": "Format 80 C", "model_qualifier": "", "winter_efficiency_pct": 81.7, "summer_efficiency_pct": 71.6, "comparative_hot_water_efficiency_pct": 50.4, "output_kw_max": 23.4, "final_year_of_manufacture": 2018, "raw": ["009102", "000213", "0", "2018/Feb/26 17:05", "Fonderie Sime S.p.A.", "Sime", "Format 80 C", "", "LPG", "2001", "2018", "2", "2", "1", "2", "0", "", "", "1", "2", "2", "23.4", "23.4", "", "", "81.7", "71.6", "", "50.4", "", "2", "1", "", "104", "1", "2", "150", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "83.5", "82.3", "", "", "", "", "82.6"]} -{"pcdb_id": 9103, "brand_name": "Sime", "model_name": "Super 90 MK II", "model_qualifier": "", "winter_efficiency_pct": 82.0, "summer_efficiency_pct": 71.9, "comparative_hot_water_efficiency_pct": 50.6, "output_kw_max": 23.68, "final_year_of_manufacture": 2018, "raw": ["009103", "000213", "0", "2018/Mar/05 15:07", "Fonderie Sime S.p.A.", "Sime", "Super 90 MK II", "", "LPG", "2000", "2018", "2", "2", "1", "2", "0", "", "", "1", "2", "2", "23.68", "23.68", "", "", "82.0", "71.9", "", "50.6", "", "2", "1", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "84.5", "81.9", "", "", "", "", "82.4"]} -{"pcdb_id": 9104, "brand_name": "Sime", "model_name": "Friendly Format 100 E", "model_qualifier": "", "winter_efficiency_pct": 81.3, "summer_efficiency_pct": 71.2, "comparative_hot_water_efficiency_pct": 50.1, "output_kw_max": 29.0, "final_year_of_manufacture": 2018, "raw": ["009104", "000213", "0", "2018/Mar/05 14:08", "Fonderie Sime S.p.A.", "Sime", "Friendly Format 100 E", "", "LPG", "1999", "2018", "2", "2", "1", "2", "0", "", "", "1", "2", "2", "29", "29", "", "", "81.3", "71.2", "", "50.1", "", "2", "1", "", "104", "1", "2", "160", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "84.7", "80.3", "", "", "", "", "81.2"]} -{"pcdb_id": 9105, "brand_name": "Sime", "model_name": "Friendly Format 80 E", "model_qualifier": "", "winter_efficiency_pct": 82.0, "summer_efficiency_pct": 71.9, "comparative_hot_water_efficiency_pct": 50.6, "output_kw_max": 23.7, "final_year_of_manufacture": 2018, "raw": ["009105", "000213", "0", "2018/Mar/05 14:09", "Fonderie Sime S.p.A.", "Sime", "Friendly Format 80 E", "", "LPG", "1998", "2018", "2", "2", "1", "2", "0", "", "", "1", "2", "2", "23.7", "23.7", "", "", "82.0", "71.9", "", "50.6", "", "2", "1", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "84.5", "81.9", "", "", "", "", "82.4"]} -{"pcdb_id": 9106, "brand_name": "Sime", "model_name": "Planet Super 4 W.M..", "model_qualifier": "", "winter_efficiency_pct": 83.4, "summer_efficiency_pct": 74.3, "comparative_hot_water_efficiency_pct": 39.9, "output_kw_max": 29.5, "final_year_of_manufacture": 2018, "raw": ["009106", "000213", "0", "2024/Jan/31 10:17", "Fonderie Sime S.p.A.", "Sime", "Planet Super 4 W.M..", "", "LPG", "2000", "2018", "2", "2", "1", "2", "0", "", "", "1", "2", "2", "29.5", "29.5", "", "", "83.4", "74.3", "", "39.9", "", "2", "1", "", "106", "1", "2", "180", "0", "2", "1", "0", "65", "0", "18", "2", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "86.1", "84.6", "", "", "", "", "84.9"]} -{"pcdb_id": 9108, "brand_name": "Sime", "model_name": "Planet Super 4 F.S.", "model_qualifier": "", "winter_efficiency_pct": 83.1, "summer_efficiency_pct": 74.0, "comparative_hot_water_efficiency_pct": 38.7, "output_kw_max": 29.4, "final_year_of_manufacture": 2018, "raw": ["009108", "000213", "0", "2024/Jan/31 10:17", "Fonderie Sime S.p.A.", "Sime", "Planet Super 4 F.S.", "", "LPG", "2002", "2018", "2", "1", "1", "2", "0", "", "", "1", "2", "2", "29.4", "29.4", "", "", "83.1", "74.0", "", "38.7", "", "2", "1", "", "106", "1", "2", "180", "0", "2", "1", "0", "62", "0", "16", "2", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "84.5", "83.4", "", "", "", "", "83.7"]} -{"pcdb_id": 9109, "brand_name": "Sime", "model_name": "Super 105 MK II", "model_qualifier": "", "winter_efficiency_pct": 81.3, "summer_efficiency_pct": 71.2, "comparative_hot_water_efficiency_pct": 50.1, "output_kw_max": 30.5, "final_year_of_manufacture": 2018, "raw": ["009109", "000213", "0", "2018/Mar/05 15:07", "Fonderie Sime S.p.A.", "Sime", "Super 105 MK II", "", "LPG", "2000", "2018", "2", "2", "1", "2", "0", "", "", "1", "2", "2", "30.5", "30.5", "", "", "81.3", "71.2", "", "50.1", "", "2", "1", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "84.7", "80.3", "", "", "", "", "81.2"]} -{"pcdb_id": 9110, "brand_name": "Sime", "model_name": "RX 37 CE IONO", "model_qualifier": "", "winter_efficiency_pct": 81.6, "summer_efficiency_pct": 71.5, "comparative_hot_water_efficiency_pct": 52.2, "output_kw_max": 39.1, "final_year_of_manufacture": 2018, "raw": ["009110", "000213", "0", "2018/Mar/05 15:02", "Fonderie Sime S.p.A.", "Sime", "RX 37 CE IONO", "", "LPG", "1998", "2018", "2", "1", "1", "1", "0", "", "", "1", "1", "1", "39.1", "39.1", "", "", "81.6", "71.5", "", "52.2", "", "2", "1", "", "101", "1", "1", "16", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.5", "87.6", "", "", "", "", "86.6"]} -{"pcdb_id": 9111, "brand_name": "Sime", "model_name": "RX 48 CE IONO", "model_qualifier": "", "winter_efficiency_pct": 82.7, "summer_efficiency_pct": 72.6, "comparative_hot_water_efficiency_pct": 53.0, "output_kw_max": 48.8, "final_year_of_manufacture": 2018, "raw": ["009111", "000213", "0", "2018/Mar/05 15:03", "Fonderie Sime S.p.A.", "Sime", "RX 48 CE IONO", "", "LPG", "1998", "2018", "2", "1", "1", "1", "0", "", "", "1", "1", "1", "48.8", "48.8", "", "", "82.7", "72.6", "", "53.0", "", "2", "1", "", "101", "1", "1", "16", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "84.8", "84.5", "", "", "", "", "84.6"]} -{"pcdb_id": 9112, "brand_name": "Sime", "model_name": "RX 55 CE IONO", "model_qualifier": "", "winter_efficiency_pct": 82.7, "summer_efficiency_pct": 72.6, "comparative_hot_water_efficiency_pct": 53.0, "output_kw_max": 60.7, "final_year_of_manufacture": 2018, "raw": ["009112", "000213", "0", "2018/Mar/05 15:05", "Fonderie Sime S.p.A.", "Sime", "RX 55 CE IONO", "", "LPG", "1998", "2018", "2", "1", "1", "1", "0", "", "", "1", "1", "1", "60.7", "60.7", "", "", "82.7", "72.6", "", "53.0", "", "2", "1", "", "101", "1", "1", "16", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "84.8", "84.5", "", "", "", "", "84.6"]} -{"pcdb_id": 9113, "brand_name": "Firebird", "model_name": "Boilerhouse S", "model_qualifier": "50-70", "winter_efficiency_pct": 85.0, "summer_efficiency_pct": 73.3, "comparative_hot_water_efficiency_pct": 53.6, "output_kw_max": 20.52, "final_year_of_manufacture": 2013, "raw": ["009113", "000047", "0", "2018/Jan/03 13:35", "Firebird Boilers", "Firebird", "Boilerhouse S", "50-70", "", "", "2013", "4", "1", "1", "1", "0", "", "", "1", "2", "1", "14.65", "20.52", "", "", "85.0", "73.3", "", "53.6", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.5", "84.6", "", "", "", "", "84.8"]} -{"pcdb_id": 9114, "brand_name": "Firebird", "model_name": "S (White Cased)", "model_qualifier": "50-70", "winter_efficiency_pct": 85.0, "summer_efficiency_pct": 73.3, "comparative_hot_water_efficiency_pct": 53.6, "output_kw_max": 20.52, "final_year_of_manufacture": 2013, "raw": ["009114", "000047", "0", "2018/Jan/03 13:37", "Firebird Boilers", "Firebird", "S (White Cased)", "50-70", "", "", "2013", "4", "1", "1", "1", "0", "", "", "1", "2", "1", "14.65", "20.52", "", "", "85.0", "73.3", "", "53.6", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.5", "84.6", "", "", "", "", "84.8"]} -{"pcdb_id": 9115, "brand_name": "Firebird", "model_name": "Oylympic S", "model_qualifier": "50-82", "winter_efficiency_pct": 86.1, "summer_efficiency_pct": 74.4, "comparative_hot_water_efficiency_pct": 54.4, "output_kw_max": 24.03, "final_year_of_manufacture": 2010, "raw": ["009115", "000047", "0", "2012/Mar/27 10:12", "Firebird Boilers", "Firebird", "Oylympic S", "50-82", "", "", "2010", "4", "1", "1", "1", "0", "", "", "1", "2", "1", "14.65", "24.03", "", "", "86.1", "74.4", "", "54.4", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.8", "86.4", "", "", "", "", "86.3"]} -{"pcdb_id": 9116, "brand_name": "Firebird", "model_name": "Oylympic Boilerhouse", "model_qualifier": "50-82", "winter_efficiency_pct": 86.1, "summer_efficiency_pct": 74.4, "comparative_hot_water_efficiency_pct": 54.4, "output_kw_max": 24.03, "final_year_of_manufacture": 2010, "raw": ["009116", "000047", "0", "2012/Mar/27 10:12", "Firebird Boilers", "Firebird", "Oylympic Boilerhouse", "50-82", "", "", "2010", "4", "1", "1", "1", "0", "", "", "1", "2", "1", "14.65", "24.03", "", "", "86.1", "74.4", "", "54.4", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.8", "86.4", "", "", "", "", "86.3"]} -{"pcdb_id": 9117, "brand_name": "Firebird", "model_name": "Oylympic De Luxe", "model_qualifier": "50-82", "winter_efficiency_pct": 86.1, "summer_efficiency_pct": 74.4, "comparative_hot_water_efficiency_pct": 54.4, "output_kw_max": 24.03, "final_year_of_manufacture": 2010, "raw": ["009117", "000047", "0", "2012/Mar/27 10:12", "Firebird Boilers", "Firebird", "Oylympic De Luxe", "50-82", "", "", "2010", "4", "1", "1", "1", "0", "", "", "1", "2", "1", "14.65", "24.03", "", "", "86.1", "74.4", "", "54.4", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.8", "86.4", "", "", "", "", "86.3"]} -{"pcdb_id": 9118, "brand_name": "Firebird", "model_name": "CombiPac", "model_qualifier": "90", "winter_efficiency_pct": 84.2, "summer_efficiency_pct": 76.1, "comparative_hot_water_efficiency_pct": 43.4, "output_kw_max": 26.38, "final_year_of_manufacture": 2013, "raw": ["009118", "000047", "0", "2024/Jan/31 10:17", "Firebird Boilers", "Firebird", "CombiPac", "90", "", "1997", "2013", "4", "1", "2", "2", "0", "", "", "1", "1", "1", "26.38", "26.38", "", "", "84.2", "76.1", "", "43.4", "", "2", "", "", "203", "1", "1", "138", "0", "1", "2", "0", "25", "0", "25", "3", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.6", "85.9", "", "", "", "", "86.0"]} -{"pcdb_id": 9119, "brand_name": "Firebird", "model_name": "Boilerhouse S", "model_qualifier": "70-90", "winter_efficiency_pct": 86.1, "summer_efficiency_pct": 74.4, "comparative_hot_water_efficiency_pct": 54.4, "output_kw_max": 26.38, "final_year_of_manufacture": 2013, "raw": ["009119", "000047", "0", "2018/Jan/03 13:29", "Firebird Boilers", "Firebird", "Boilerhouse S", "70-90", "", "", "2013", "4", "1", "1", "1", "0", "", "", "1", "2", "1", "20.52", "26.38", "", "", "86.1", "74.4", "", "54.4", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.8", "86.4", "", "", "", "", "86.3"]} -{"pcdb_id": 9120, "brand_name": "Firebird", "model_name": "S (White Cased)", "model_qualifier": "70-90", "winter_efficiency_pct": 86.1, "summer_efficiency_pct": 74.4, "comparative_hot_water_efficiency_pct": 54.4, "output_kw_max": 26.38, "final_year_of_manufacture": 2013, "raw": ["009120", "000047", "0", "2018/Jan/03 13:30", "Firebird Boilers", "Firebird", "S (White Cased)", "70-90", "", "", "2013", "4", "1", "1", "1", "0", "", "", "1", "2", "1", "20.52", "26.38", "", "", "86.1", "74.4", "", "54.4", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.8", "86.4", "", "", "", "", "86.3"]} -{"pcdb_id": 9121, "brand_name": "Firebird", "model_name": "Sealed System", "model_qualifier": "70-90", "winter_efficiency_pct": 86.1, "summer_efficiency_pct": 74.4, "comparative_hot_water_efficiency_pct": 54.4, "output_kw_max": 26.38, "final_year_of_manufacture": 2013, "raw": ["009121", "000047", "0", "2018/Jan/03 13:31", "Firebird Boilers", "Firebird", "Sealed System", "70-90", "", "", "2013", "4", "1", "1", "1", "0", "", "", "1", "2", "1", "20.52", "26.38", "", "", "86.1", "74.4", "", "54.4", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.8", "86.4", "", "", "", "", "86.3"]} -{"pcdb_id": 9122, "brand_name": "Firebird", "model_name": "Heatpac", "model_qualifier": "70-90", "winter_efficiency_pct": 86.1, "summer_efficiency_pct": 74.4, "comparative_hot_water_efficiency_pct": 54.4, "output_kw_max": 26.38, "final_year_of_manufacture": 2013, "raw": ["009122", "000047", "0", "2018/Jan/03 13:31", "Firebird Boilers", "Firebird", "Heatpac", "70-90", "", "", "2013", "4", "1", "2", "1", "0", "", "", "1", "1", "1", "20.52", "26.38", "", "", "86.1", "74.4", "", "54.4", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.8", "86.4", "", "", "", "", "86.3"]} -{"pcdb_id": 9123, "brand_name": "Firebird", "model_name": "Heatpac Sealed System", "model_qualifier": "70-90", "winter_efficiency_pct": 86.1, "summer_efficiency_pct": 74.4, "comparative_hot_water_efficiency_pct": 54.4, "output_kw_max": 26.38, "final_year_of_manufacture": 2013, "raw": ["009123", "000047", "0", "2018/Jan/03 13:32", "Firebird Boilers", "Firebird", "Heatpac Sealed System", "70-90", "", "", "2013", "4", "1", "2", "1", "0", "", "", "1", "1", "1", "20.52", "26.38", "", "", "86.1", "74.4", "", "54.4", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.8", "86.4", "", "", "", "", "86.3"]} -{"pcdb_id": 9124, "brand_name": "Firebird", "model_name": "Combipac", "model_qualifier": "115", "winter_efficiency_pct": 84.0, "summer_efficiency_pct": 75.9, "comparative_hot_water_efficiency_pct": 43.2, "output_kw_max": 33.7, "final_year_of_manufacture": 2010, "raw": ["009124", "000047", "0", "2024/Jan/31 10:17", "Firebird Boilers", "Firebird", "Combipac", "115", "", "1997", "2010", "4", "1", "2", "2", "0", "", "", "1", "1", "1", "33.7", "33.7", "", "", "84.0", "75.9", "", "43.2", "", "2", "", "", "203", "1", "1", "138", "0", "1", "2", "0", "25", "0", "25", "3", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.1", "85.5", "", "", "", "", "85.7"]} -{"pcdb_id": 9125, "brand_name": "Firebird", "model_name": "Oylympic Boilerhouse", "model_qualifier": "90-115", "winter_efficiency_pct": 86.4, "summer_efficiency_pct": 74.7, "comparative_hot_water_efficiency_pct": 54.6, "output_kw_max": 33.7, "final_year_of_manufacture": 2010, "raw": ["009125", "000047", "0", "2012/Mar/27 10:12", "Firebird Boilers", "Firebird", "Oylympic Boilerhouse", "90-115", "", "1997", "2010", "4", "1", "1", "1", "0", "", "", "1", "2", "1", "26.38", "33.70", "", "", "86.4", "74.7", "", "54.6", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.4", "86.7", "", "", "", "", "86.6"]} -{"pcdb_id": 9126, "brand_name": "Firebird", "model_name": "Oylympic S", "model_qualifier": "90-115", "winter_efficiency_pct": 86.4, "summer_efficiency_pct": 74.7, "comparative_hot_water_efficiency_pct": 54.6, "output_kw_max": 33.7, "final_year_of_manufacture": 2010, "raw": ["009126", "000047", "0", "2012/Mar/27 10:12", "Firebird Boilers", "Firebird", "Oylympic S", "90-115", "", "1997", "2010", "4", "1", "1", "1", "0", "", "", "1", "2", "1", "26.38", "33.70", "", "", "86.4", "74.7", "", "54.6", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.4", "86.7", "", "", "", "", "86.6"]} -{"pcdb_id": 9127, "brand_name": "Firebird", "model_name": "Heatpac S", "model_qualifier": "70-90", "winter_efficiency_pct": 86.1, "summer_efficiency_pct": 74.4, "comparative_hot_water_efficiency_pct": 54.4, "output_kw_max": 26.38, "final_year_of_manufacture": 2013, "raw": ["009127", "000047", "0", "2018/Jan/03 13:34", "Firebird Boilers", "Firebird", "Heatpac S", "70-90", "", "", "2013", "4", "1", "2", "1", "0", "", "", "1", "1", "1", "20.52", "26.38", "", "", "86.1", "74.4", "", "54.4", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.8", "86.4", "", "", "", "", "86.3"]} -{"pcdb_id": 9128, "brand_name": "Broag Remeha", "model_name": "Selecta", "model_qualifier": "Selecta Combi", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 56.3, "output_kw_max": 16.0, "final_year_of_manufacture": null, "raw": ["009128", "000006", "0", "2006/Jan/17 12:31", "Remeha", "Broag Remeha", "Selecta", "Selecta Combi", "0063BL3537", "2000", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "16", "16", "", "", "88.7", "80.1", "", "56.3", "", "2", "", "", "104", "1", "2", "130", "8", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "98.5", "", "", "", "", "96.5"]} -{"pcdb_id": 9129, "brand_name": "Broag Remeha", "model_name": "Selecta", "model_qualifier": "Selecta System", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 16.0, "final_year_of_manufacture": null, "raw": ["009129", "000006", "0", "2012/Mar/27 10:12", "Remeha", "Broag Remeha", "Selecta", "Selecta System", "0063BL3537", "2000", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "16", "16", "", "", "88.7", "79.7", "", "58.2", "", "2", "", "", "102", "1", "2", "130", "8", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "98.5", "", "", "", "", "96.5"]} -{"pcdb_id": 9130, "brand_name": "Vokera", "model_name": "Mynute 12e", "model_qualifier": "", "winter_efficiency_pct": 80.1, "summer_efficiency_pct": 70.0, "comparative_hot_water_efficiency_pct": 51.1, "output_kw_max": 12.0, "final_year_of_manufacture": 2010, "raw": ["009130", "000011", "0", "2012/Mar/27 10:12", "Vokera", "Vokera", "Mynute 12e", "", "141", "2002", "2010", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "7.4", "12.0", "", "", "80.1", "70.0", "", "51.1", "", "2", "", "", "101", "1", "1", "125", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "83.3", "80.5", "", "", "", "", "81.0"]} -{"pcdb_id": 9131, "brand_name": "Vokera", "model_name": "Mynute 16e", "model_qualifier": "", "winter_efficiency_pct": 80.5, "summer_efficiency_pct": 70.4, "comparative_hot_water_efficiency_pct": 51.4, "output_kw_max": 16.0, "final_year_of_manufacture": 2010, "raw": ["009131", "000011", "0", "2012/Mar/27 10:12", "Vokera", "Vokera", "Mynute 16e", "", "143", "2002", "2010", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "12", "16.0", "", "", "80.5", "70.4", "", "51.4", "", "2", "", "", "101", "1", "1", "125", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "83.4", "81.4", "", "", "", "", "81.8"]} -{"pcdb_id": 9133, "brand_name": "NST", "model_name": "Sogno Eli 8-22", "model_qualifier": "M", "winter_efficiency_pct": 83.2, "summer_efficiency_pct": 73.1, "comparative_hot_water_efficiency_pct": 51.4, "output_kw_max": 22.42, "final_year_of_manufacture": 2003, "raw": ["009133", "000216", "0", "2006/Jan/17 12:55", "NST Nvovi Sistemi Termotecnici", "NST", "Sogno Eli 8-22", "M", "", "1997", "2003", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "22.42", "22.42", "", "", "83.2", "73.1", "", "51.4", "", "2", "", "", "104", "1", "2", "68", "40", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "86.3", "86.0", "", "", "", "", "86.0"]} -{"pcdb_id": 9145, "brand_name": "Turkington Engineering", "model_name": "Turco Trojan", "model_qualifier": "50/90", "winter_efficiency_pct": 86.4, "summer_efficiency_pct": 74.7, "comparative_hot_water_efficiency_pct": 54.6, "output_kw_max": 26.37, "final_year_of_manufacture": null, "raw": ["009145", "000218", "0", "2012/Mar/27 10:12", "Turkington Engineering", "Turkington Engineering", "Turco Trojan", "50/90", "", "1996", "current", "4", "1", "2", "1", "0", "", "", "1", "1", "1", "14.65", "26.37", "", "", "86.4", "74.7", "", "54.6", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.7", "87.7", "", "", "", "", "87.3"]} -{"pcdb_id": 9146, "brand_name": "Turkington Engineering", "model_name": "Turco Trojan Boiler House", "model_qualifier": "50/90", "winter_efficiency_pct": 86.4, "summer_efficiency_pct": 74.7, "comparative_hot_water_efficiency_pct": 54.6, "output_kw_max": 26.37, "final_year_of_manufacture": null, "raw": ["009146", "000218", "0", "2012/Mar/27 10:12", "Turkington Engineering", "Turkington Engineering", "Turco Trojan Boiler House", "50/90", "", "1996", "current", "4", "1", "2", "1", "0", "", "", "1", "1", "1", "14.65", "26.37", "", "", "86.4", "74.7", "", "54.6", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.7", "87.7", "", "", "", "", "87.3"]} -{"pcdb_id": 9147, "brand_name": "Turkington Engineering", "model_name": "Turco Trojan White Cased", "model_qualifier": "50/90", "winter_efficiency_pct": 86.4, "summer_efficiency_pct": 74.7, "comparative_hot_water_efficiency_pct": 54.6, "output_kw_max": 26.37, "final_year_of_manufacture": null, "raw": ["009147", "000218", "0", "2012/Mar/27 10:12", "Turkington Engineering", "Turkington Engineering", "Turco Trojan White Cased", "50/90", "", "1996", "current", "4", "1", "2", "1", "0", "", "", "1", "1", "1", "14.65", "26.37", "", "", "86.4", "74.7", "", "54.6", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.7", "87.7", "", "", "", "", "87.3"]} -{"pcdb_id": 9148, "brand_name": "Turkington Engineering", "model_name": "Turco Trojan Outdoor", "model_qualifier": "50/90", "winter_efficiency_pct": 86.4, "summer_efficiency_pct": 74.7, "comparative_hot_water_efficiency_pct": 54.6, "output_kw_max": 26.37, "final_year_of_manufacture": null, "raw": ["009148", "000218", "0", "2012/Mar/27 10:12", "Turkington Engineering", "Turkington Engineering", "Turco Trojan Outdoor", "50/90", "", "1996", "current", "4", "1", "2", "1", "0", "", "", "1", "1", "1", "14.65", "26.37", "", "", "86.4", "74.7", "", "54.6", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.7", "87.7", "", "", "", "", "87.3"]} -{"pcdb_id": 9149, "brand_name": "Turkington Engineering", "model_name": "Eurocal White Cased Utility", "model_qualifier": "70/90", "winter_efficiency_pct": 86.4, "summer_efficiency_pct": 74.7, "comparative_hot_water_efficiency_pct": 54.6, "output_kw_max": 20.5, "final_year_of_manufacture": null, "raw": ["009149", "000218", "0", "2012/Mar/27 10:12", "Turkington Engineering", "Turkington Engineering", "Eurocal White Cased Utility", "70/90", "", "1996", "current", "4", "1", "2", "1", "0", "", "", "1", "1", "1", "14.65", "20.50", "", "", "86.4", "74.7", "", "54.6", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.7", "87.7", "", "", "", "", "87.3"]} -{"pcdb_id": 9150, "brand_name": "Turkington Engineering", "model_name": "Turco Trojan Boiler House", "model_qualifier": "50/70", "winter_efficiency_pct": 86.4, "summer_efficiency_pct": 74.7, "comparative_hot_water_efficiency_pct": 54.6, "output_kw_max": 20.5, "final_year_of_manufacture": null, "raw": ["009150", "000218", "0", "2012/Mar/27 10:12", "Turkington Engineering", "Turkington Engineering", "Turco Trojan Boiler House", "50/70", "", "1996", "current", "4", "1", "2", "1", "0", "", "", "1", "1", "1", "14.65", "20.50", "", "", "86.4", "74.7", "", "54.6", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.7", "87.7", "", "", "", "", "87.3"]} -{"pcdb_id": 9151, "brand_name": "Turkington Engineering", "model_name": "Eurocal White Cased Utility", "model_qualifier": "50/70", "winter_efficiency_pct": 86.4, "summer_efficiency_pct": 74.7, "comparative_hot_water_efficiency_pct": 54.6, "output_kw_max": 20.5, "final_year_of_manufacture": null, "raw": ["009151", "000218", "0", "2012/Mar/27 10:12", "Turkington Engineering", "Turkington Engineering", "Eurocal White Cased Utility", "50/70", "", "1996", "current", "4", "1", "2", "1", "0", "", "", "1", "1", "1", "14.65", "20.50", "", "", "86.4", "74.7", "", "54.6", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.7", "87.7", "", "", "", "", "87.3"]} -{"pcdb_id": 9152, "brand_name": "HRM Boilers", "model_name": "Wallstar 12/15", "model_qualifier": "11", "winter_efficiency_pct": 85.3, "summer_efficiency_pct": 73.6, "comparative_hot_water_efficiency_pct": 53.8, "output_kw_max": 15.0, "final_year_of_manufacture": null, "raw": ["009152", "000098", "0", "2012/Mar/27 10:12", "HRM Boilers", "HRM Boilers", "Wallstar 12/15", "11", "20020422", "2002", "current", "4", "2", "1", "1", "0", "", "", "1", "2", "2", "12", "15", "", "", "85.3", "73.6", "", "53.8", "", "2", "", "", "201", "1", "1", "140", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.3", "85.4", "", "", "", "", "85.3"]} -{"pcdb_id": 9153, "brand_name": "Boulter", "model_name": "Camray 5", "model_qualifier": "200/240", "winter_efficiency_pct": 85.5, "summer_efficiency_pct": 73.8, "comparative_hot_water_efficiency_pct": 53.9, "output_kw_max": null, "final_year_of_manufacture": null, "raw": ["009153", "000041", "0", "2012/Mar/27 10:12", "Boulter Boilers", "Boulter", "Camray 5", "200/240", "", "2002", "current", "4", "1", "1", "1", "0", "", "", "1", "3", "2", "58.6", ">70kW", "", "", "85.5", "73.8", "", "53.9", "", "2", "", "", "201", "1", "1", "150", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.0", "86.1", "", "", "", "", "85.9"]} -{"pcdb_id": 9155, "brand_name": "Ideal", "model_name": "Mini S28", "model_qualifier": "28kW System Boiler", "winter_efficiency_pct": 79.4, "summer_efficiency_pct": 68.7, "comparative_hot_water_efficiency_pct": 50.2, "output_kw_max": 28.0, "final_year_of_manufacture": 2009, "raw": ["009155", "000008", "0", "2018/Oct/15 12:00", "Savio Caldaie SpA", "Ideal", "Mini S28", "28kW System Boiler", "0694BM3420", "2002", "2009", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "28", "28", "", "", "79.4", "68.7", "", "50.2", "", "2", "", "", "102", "1", "2", "170", "7", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.2", "78.6", "", "", "", "", "79.3"]} -{"pcdb_id": 9156, "brand_name": "Ideal", "model_name": "Mini S24", "model_qualifier": "24kW System Boiler", "winter_efficiency_pct": 79.3, "summer_efficiency_pct": 68.6, "comparative_hot_water_efficiency_pct": 50.1, "output_kw_max": 24.3, "final_year_of_manufacture": 2009, "raw": ["009156", "000008", "0", "2018/Oct/15 12:00", "Savio Caldaie SpA", "Ideal", "Mini S24", "24kW System Boiler", "0694BM3420", "2002", "2009", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "24.3", "24.3", "", "", "79.3", "68.6", "", "50.1", "", "2", "", "", "102", "1", "2", "150", "7", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.3", "78.4", "", "", "", "", "79.1"]} -{"pcdb_id": 9157, "brand_name": "Ideal", "model_name": "Mini C28", "model_qualifier": "28kW Combi Boiler", "winter_efficiency_pct": 79.2, "summer_efficiency_pct": 69.1, "comparative_hot_water_efficiency_pct": 48.6, "output_kw_max": 28.0, "final_year_of_manufacture": 2004, "raw": ["009157", "000008", "0", "2018/Oct/15 12:00", "Savio Caldaie SpA", "Ideal", "Mini C28", "28kW Combi Boiler", "0694BM3420", "2002", "2004", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "28", "28", "", "", "79.2", "69.1", "", "48.6", "", "2", "", "", "104", "1", "2", "170", "7", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.2", "78.6", "", "", "", "", "79.3"]} -{"pcdb_id": 9158, "brand_name": "Ideal", "model_name": "Mini C24", "model_qualifier": "24kW Combi Boiler", "winter_efficiency_pct": 79.1, "summer_efficiency_pct": 69.0, "comparative_hot_water_efficiency_pct": 48.5, "output_kw_max": 24.3, "final_year_of_manufacture": 2004, "raw": ["009158", "000008", "0", "2018/Oct/15 12:00", "Savio Caldaie SpA", "Ideal", "Mini C24", "24kW Combi Boiler", "0694BM3420", "2002", "2004", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "24.3", "24.3", "", "", "79.1", "69.0", "", "48.5", "", "2", "", "", "104", "1", "2", "150", "7", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "0", "0004", "", "", "", "", "", "", "", "", "82.3", "78.4", "", "", "", "", "79.1"]} -{"pcdb_id": 9159, "brand_name": "Europa", "model_name": "24", "model_qualifier": "24kW Combi Boiler", "winter_efficiency_pct": 79.8, "summer_efficiency_pct": 69.7, "comparative_hot_water_efficiency_pct": 49.0, "output_kw_max": 24.3, "final_year_of_manufacture": null, "raw": ["009159", "000008", "0", "2002/May/13 11:14", "Unical AG SpA", "Europa", "24", "24kW Combi Boiler", "49AU2867", "2002", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "24.3", "24.3", "", "", "79.8", "69.7", "", "49.0", "", "2", "", "", "104", "1", "2", "137", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.5", "80.5", "", "", "", "", "80.6"]} -{"pcdb_id": 9160, "brand_name": "Europa", "model_name": "28", "model_qualifier": "28 kW Combi Boiler", "winter_efficiency_pct": 80.7, "summer_efficiency_pct": 70.6, "comparative_hot_water_efficiency_pct": 49.7, "output_kw_max": 28.0, "final_year_of_manufacture": null, "raw": ["009160", "000008", "0", "2002/May/13 11:14", "Unical AG SpA", "Europa", "28", "28 kW Combi Boiler", "49AU2949", "2002", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "28", "28", "", "", "80.7", "70.6", "", "49.7", "", "2", "", "", "104", "1", "2", "137", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.5", "81.4", "", "", "", "", "81.6"]} -{"pcdb_id": 9161, "brand_name": "Boxer", "model_name": "C24", "model_qualifier": "24kW Combi Boiler", "winter_efficiency_pct": 79.8, "summer_efficiency_pct": 69.7, "comparative_hot_water_efficiency_pct": 49.0, "output_kw_max": 24.3, "final_year_of_manufacture": null, "raw": ["009161", "000008", "0", "2002/May/13 11:15", "Unical AG SpA", "Boxer", "C24", "24kW Combi Boiler", "49AU2867", "2002", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "24.3", "24.3", "", "", "79.8", "69.7", "", "49.0", "", "2", "", "", "104", "1", "2", "137", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.5", "80.5", "", "", "", "", "80.6"]} -{"pcdb_id": 9162, "brand_name": "Boxer", "model_name": "C28", "model_qualifier": "28kW Combi Boiler", "winter_efficiency_pct": 79.8, "summer_efficiency_pct": 69.7, "comparative_hot_water_efficiency_pct": 49.0, "output_kw_max": 24.3, "final_year_of_manufacture": null, "raw": ["009162", "000008", "0", "2002/May/13 11:15", "Unical AG SpA", "Boxer", "C28", "28kW Combi Boiler", "49AU2867", "2002", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "24.3", "24.3", "", "", "79.8", "69.7", "", "49.0", "", "2", "", "", "104", "1", "2", "137", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.6", "80.5", "", "", "", "", "80.7"]} -{"pcdb_id": 9163, "brand_name": "Geminox", "model_name": "THR 2-13C", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 14.7, "final_year_of_manufacture": 2006, "raw": ["009163", "000212", "0", "2012/Mar/27 10:12", "Geminox SA", "Geminox", "THR 2-13C", "", "2-13C", "1997", "2006", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "14.7", "14.7", "", "", "88.3", "79.3", "", "58.0", "", "2", "", "", "102", "1", "2", "90", "15", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "97.8", "", "", "", "", "95.9"]} -{"pcdb_id": 9170, "brand_name": "Broag Remeha", "model_name": "Selecta", "model_qualifier": "Selecta System", "winter_efficiency_pct": 89.7, "summer_efficiency_pct": 80.7, "comparative_hot_water_efficiency_pct": 58.9, "output_kw_max": 16.0, "final_year_of_manufacture": null, "raw": ["009170", "000006", "0", "2012/Mar/27 10:12", "Remeha", "Broag Remeha", "Selecta", "Selecta System", "0063BL3537", "2000", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "16", "16", "", "", "89.7", "80.7", "", "58.9", "", "2", "1", "", "102", "1", "2", "130", "8", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.9", "100.7", "", "", "", "", "98.6"]} -{"pcdb_id": 9171, "brand_name": "Broag Remeha", "model_name": "Selecta", "model_qualifier": "Selecta Combi", "winter_efficiency_pct": 89.7, "summer_efficiency_pct": 81.1, "comparative_hot_water_efficiency_pct": 57.0, "output_kw_max": 16.0, "final_year_of_manufacture": null, "raw": ["009171", "000006", "0", "2006/Jan/17 12:31", "Remeha", "Broag Remeha", "Selecta", "Selecta Combi", "0063BL3537", "2000", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "16", "16", "", "", "89.7", "81.1", "", "57.0", "", "2", "1", "", "104", "1", "2", "130", "8", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.9", "100.7", "", "", "", "", "98.6"]} -{"pcdb_id": 9177, "brand_name": "Ravenheat", "model_name": "Little Star LS 80", "model_qualifier": "", "winter_efficiency_pct": 80.5, "summer_efficiency_pct": 70.4, "comparative_hot_water_efficiency_pct": 49.5, "output_kw_max": 24.1, "final_year_of_manufacture": null, "raw": ["009177", "000026", "0", "2006/Jan/17 12:31", "Ravenheat", "Ravenheat", "Little Star LS 80", "", "", "2002", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "24.1", "24.1", "", "", "80.5", "70.4", "", "49.5", "", "2", "", "", "104", "1", "2", "150", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "", "", "0004", "", "", "", "", "", "", "", "", "83.3", "80.5", "", "", "", "", "81.1"]} -{"pcdb_id": 9178, "brand_name": "Ravenheat", "model_name": "Little Star LS 80 (T)", "model_qualifier": "", "winter_efficiency_pct": 80.5, "summer_efficiency_pct": 70.4, "comparative_hot_water_efficiency_pct": 49.5, "output_kw_max": 24.1, "final_year_of_manufacture": null, "raw": ["009178", "000026", "0", "2006/Jan/17 12:31", "Ravenheat", "Ravenheat", "Little Star LS 80 (T)", "", "", "2002", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "24.1", "24.1", "", "", "80.5", "70.4", "", "49.5", "", "2", "", "", "104", "1", "2", "150", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "", "", "0004", "", "", "", "", "", "", "", "", "83.3", "80.5", "", "", "", "", "81.1"]} -{"pcdb_id": 9179, "brand_name": "Sime", "model_name": "Superior 40 Ci", "model_qualifier": "", "winter_efficiency_pct": 79.9, "summer_efficiency_pct": 69.8, "comparative_hot_water_efficiency_pct": 51.0, "output_kw_max": 11.8, "final_year_of_manufacture": 2018, "raw": ["009179", "000213", "0", "2018/Mar/05 15:08", "Fonderie Sime S.p.A.", "Sime", "Superior 40 Ci", "", "", "2002", "2018", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "8.8", "11.8", "", "", "79.9", "69.8", "", "51.0", "", "2", "", "", "101", "1", "1", "55", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.9", "81.1", "", "", "", "", "81.2"]} -{"pcdb_id": 9180, "brand_name": "Sime", "model_name": "Superior 50 Ci", "model_qualifier": "", "winter_efficiency_pct": 80.9, "summer_efficiency_pct": 70.8, "comparative_hot_water_efficiency_pct": 51.7, "output_kw_max": 14.6, "final_year_of_manufacture": 2018, "raw": ["009180", "000213", "0", "2018/Mar/05 15:10", "Fonderie Sime S.p.A.", "Sime", "Superior 50 Ci", "", "", "2002", "2018", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "11.9", "14.6", "", "", "80.9", "70.8", "", "51.7", "", "2", "", "", "101", "1", "1", "55", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.7", "82.4", "", "", "", "", "82.4"]} -{"pcdb_id": 9181, "brand_name": "Sime", "model_name": "Superior 60 Ci", "model_qualifier": "", "winter_efficiency_pct": 80.3, "summer_efficiency_pct": 70.2, "comparative_hot_water_efficiency_pct": 51.3, "output_kw_max": 17.5, "final_year_of_manufacture": 2018, "raw": ["009181", "000213", "0", "2018/Mar/05 15:11", "Fonderie Sime S.p.A.", "Sime", "Superior 60 Ci", "", "", "2002", "2018", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "14.7", "17.5", "", "", "80.3", "70.2", "", "51.3", "", "2", "", "", "101", "1", "1", "60", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.8", "82.0", "", "", "", "", "82.0"]} -{"pcdb_id": 9182, "brand_name": "Sime", "model_name": "Superior 80 Ci", "model_qualifier": "", "winter_efficiency_pct": 79.5, "summer_efficiency_pct": 69.4, "comparative_hot_water_efficiency_pct": 50.7, "output_kw_max": 23.4, "final_year_of_manufacture": 2018, "raw": ["009182", "000213", "0", "2018/Mar/05 15:13", "Fonderie Sime S.p.A.", "Sime", "Superior 80 Ci", "", "", "2002", "2018", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "17.6", "23.4", "", "", "79.5", "69.4", "", "50.7", "", "2", "", "", "101", "1", "1", "65", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.2", "81.0", "", "", "", "", "81.0"]} -{"pcdb_id": 9183, "brand_name": "Sime", "model_name": "Superior 40 Ci EI", "model_qualifier": "", "winter_efficiency_pct": 79.9, "summer_efficiency_pct": 69.8, "comparative_hot_water_efficiency_pct": 51.0, "output_kw_max": 11.8, "final_year_of_manufacture": 2018, "raw": ["009183", "000213", "0", "2018/Mar/05 15:09", "Fonderie Sime S.p.A.", "Sime", "Superior 40 Ci EI", "", "", "2002", "2018", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "8.8", "11.8", "", "", "79.9", "69.8", "", "51.0", "", "2", "", "", "101", "1", "1", "55", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.9", "81.1", "", "", "", "", "81.2"]} -{"pcdb_id": 9184, "brand_name": "Sime", "model_name": "Superior 50 Ci EI", "model_qualifier": "", "winter_efficiency_pct": 80.9, "summer_efficiency_pct": 70.8, "comparative_hot_water_efficiency_pct": 51.7, "output_kw_max": 14.6, "final_year_of_manufacture": 2018, "raw": ["009184", "000213", "0", "2018/Mar/05 15:10", "Fonderie Sime S.p.A.", "Sime", "Superior 50 Ci EI", "", "", "2002", "2018", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "11.9", "14.6", "", "", "80.9", "70.8", "", "51.7", "", "2", "", "", "101", "1", "1", "55", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.7", "82.4", "", "", "", "", "82.4"]} -{"pcdb_id": 9186, "brand_name": "Sime", "model_name": "Superior 60 Ci EI", "model_qualifier": "", "winter_efficiency_pct": 80.3, "summer_efficiency_pct": 70.2, "comparative_hot_water_efficiency_pct": 51.3, "output_kw_max": 17.5, "final_year_of_manufacture": 2018, "raw": ["009186", "000213", "0", "2018/Mar/05 15:12", "Fonderie Sime S.p.A.", "Sime", "Superior 60 Ci EI", "", "", "2002", "2018", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "14.7", "17.5", "", "", "80.3", "70.2", "", "51.3", "", "2", "", "", "101", "1", "1", "60", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.8", "82.0", "", "", "", "", "82.0"]} -{"pcdb_id": 9187, "brand_name": "Sime", "model_name": "Superior 80 Ci EI", "model_qualifier": "", "winter_efficiency_pct": 79.5, "summer_efficiency_pct": 69.4, "comparative_hot_water_efficiency_pct": 50.7, "output_kw_max": 23.4, "final_year_of_manufacture": 2018, "raw": ["009187", "000213", "0", "2018/Mar/05 15:14", "Fonderie Sime S.p.A.", "Sime", "Superior 80 Ci EI", "", "", "2002", "2018", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "17.6", "23.4", "", "", "79.5", "69.4", "", "50.7", "", "2", "", "", "101", "1", "1", "65", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.2", "81.0", "", "", "", "", "81.0"]} -{"pcdb_id": 9188, "brand_name": "Vokera", "model_name": "Lineamax", "model_qualifier": "", "winter_efficiency_pct": 78.9, "summer_efficiency_pct": 69.8, "comparative_hot_water_efficiency_pct": 37.0, "output_kw_max": 28.0, "final_year_of_manufacture": 2010, "raw": ["009188", "000011", "0", "2024/Jan/31 10:17", "Vokera", "Vokera", "Lineamax", "", "47-094-30", "1999", "2010", "1", "1", "1", "2", "0", "", "", "1", "2", "2", "28", "28", "", "", "78.9", "69.8", "", "37.0", "", "2", "", "", "106", "1", "2", "150", "0", "1", "1", "0", "58", "0", "25", "3", "70", "1.0", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.7", "77.8", "", "", "", "", "78.6"]} -{"pcdb_id": 9189, "brand_name": "Warmflow", "model_name": "Goldbird", "model_qualifier": "150/200GB", "winter_efficiency_pct": 85.8, "summer_efficiency_pct": 74.1, "comparative_hot_water_efficiency_pct": 54.1, "output_kw_max": 58.62, "final_year_of_manufacture": null, "raw": ["009189", "000063", "0", "2012/Mar/27 10:12", "Warmflow Engineering", "Warmflow", "Goldbird", "150/200GB", "", "2002", "current", "4", "1", "2", "1", "0", "", "", "1", "2", "2", "44", "58.62", "", "", "85.8", "74.1", "", "54.1", "", "2", "", "", "201", "1", "1", "300", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "84.8", "86.8", "", "", "", "", "86.4"]} -{"pcdb_id": 9190, "brand_name": "Warmflow", "model_name": "Whitebird", "model_qualifier": "150/200WB", "winter_efficiency_pct": 85.8, "summer_efficiency_pct": 74.1, "comparative_hot_water_efficiency_pct": 54.1, "output_kw_max": 58.62, "final_year_of_manufacture": null, "raw": ["009190", "000063", "0", "2012/Mar/27 10:12", "Warmflow Engineering", "Warmflow", "Whitebird", "150/200WB", "", "2002", "current", "4", "1", "2", "1", "0", "", "", "1", "2", "2", "44", "58.62", "", "", "85.8", "74.1", "", "54.1", "", "2", "", "", "201", "1", "1", "300", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "84.8", "86.8", "", "", "", "", "86.4"]} -{"pcdb_id": 9191, "brand_name": "Warmflow", "model_name": "Bluebird", "model_qualifier": "150/200BB", "winter_efficiency_pct": 85.8, "summer_efficiency_pct": 74.1, "comparative_hot_water_efficiency_pct": 54.1, "output_kw_max": 58.62, "final_year_of_manufacture": null, "raw": ["009191", "000063", "0", "2012/Mar/27 10:12", "Warmflow Engineering", "Warmflow", "Bluebird", "150/200BB", "", "2002", "current", "4", "1", "2", "1", "0", "", "", "1", "2", "2", "44", "58.62", "", "", "85.8", "74.1", "", "54.1", "", "2", "", "", "201", "1", "1", "300", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "84.8", "86.8", "", "", "", "", "86.4"]} -{"pcdb_id": 9192, "brand_name": "Worcester", "model_name": "28 SI II", "model_qualifier": "RSF", "winter_efficiency_pct": 79.3, "summer_efficiency_pct": 69.2, "comparative_hot_water_efficiency_pct": 48.6, "output_kw_max": 8.1, "final_year_of_manufacture": 2005, "raw": ["009192", "000035", "0", "2020/Sep/04 08:04", "Worcester Heat Systems", "Worcester", "28 SI II", "RSF", "47-311-67", "2002", "2005", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "8.1", "8.1", "", "", "79.3", "69.2", "", "48.6", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.3", "78.7", "", "", "", "", "79.3"]} -{"pcdb_id": 9193, "brand_name": "Worcester", "model_name": "28 SI II", "model_qualifier": "RSF", "winter_efficiency_pct": 80.9, "summer_efficiency_pct": 70.8, "comparative_hot_water_efficiency_pct": 49.8, "output_kw_max": 8.1, "final_year_of_manufacture": 2005, "raw": ["009193", "000035", "0", "2020/Sep/04 08:04", "Worcester Heat Systems", "Worcester", "28 SI II", "RSF", "47-311-68", "2002", "2005", "2", "2", "1", "2", "0", "", "", "1", "2", "2", "8.1", "8.1", "", "", "80.9", "70.8", "", "49.8", "", "2", "0", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "84.5", "79.6", "", "", "", "", "80.5"]} -{"pcdb_id": 9194, "brand_name": "Worcester", "model_name": "24 SI II", "model_qualifier": "RSF", "winter_efficiency_pct": 81.4, "summer_efficiency_pct": 71.3, "comparative_hot_water_efficiency_pct": 50.1, "output_kw_max": 24.0, "final_year_of_manufacture": 2005, "raw": ["009194", "000035", "0", "2020/Sep/04 08:04", "Worcester Heat Systems", "Worcester", "24 SI II", "RSF", "47-311-66", "2002", "2005", "2", "2", "1", "2", "0", "", "", "1", "2", "2", "24", "24", "", "", "81.4", "71.3", "", "50.1", "", "2", "0", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "84.1", "81.0", "", "", "", "", "81.6"]} -{"pcdb_id": 9195, "brand_name": "Worcester", "model_name": "24 SI II", "model_qualifier": "RSF", "winter_efficiency_pct": 79.0, "summer_efficiency_pct": 68.9, "comparative_hot_water_efficiency_pct": 48.4, "output_kw_max": 24.0, "final_year_of_manufacture": 2005, "raw": ["009195", "000035", "0", "2020/Sep/04 08:04", "Worcester Heat Systems", "Worcester", "24 SI II", "RSF", "47-311-65", "2002", "2005", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "24", "24", "", "", "79.0", "68.9", "", "48.4", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.8", "78.6", "", "", "", "", "79.2"]} -{"pcdb_id": 9196, "brand_name": "Fagor Electrodomesticos S.Coop", "model_name": "FEB-20E Ecoplus", "model_qualifier": "FEB-20EUK N", "winter_efficiency_pct": 80.4, "summer_efficiency_pct": 70.3, "comparative_hot_water_efficiency_pct": 49.4, "output_kw_max": 23.26, "final_year_of_manufacture": null, "raw": ["009196", "000219", "0", "2013/Jun/25 14:28", "Fagor Electrodomesticos S.Coop", "Fagor Electrodomesticos S.Coop", "FEB-20E Ecoplus", "FEB-20EUK N", "", "1999", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "23.26", "23.26", "", "", "80.4", "70.3", "", "49.4", "", "2", "", "", "104", "1", "2", "30", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "83.2", "80.3", "", "", "", "", "80.8"]} -{"pcdb_id": 9197, "brand_name": "Fagor Electrodomesticos S.Coop", "model_name": "FEB-20E Ecoplus", "model_qualifier": "FEB-20EUK GLP", "winter_efficiency_pct": 81.9, "summer_efficiency_pct": 71.8, "comparative_hot_water_efficiency_pct": 50.5, "output_kw_max": 23.26, "final_year_of_manufacture": null, "raw": ["009197", "000219", "0", "2013/Jun/25 14:28", "Fagor Electrodomesticos S.Coop", "Fagor Electrodomesticos S.Coop", "FEB-20E Ecoplus", "FEB-20EUK GLP", "", "1999", "current", "2", "2", "1", "2", "0", "", "", "1", "2", "2", "23.26", "23.26", "", "", "81.9", "71.8", "", "50.5", "", "2", "0", "", "104", "1", "2", "30", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "84.2", "82.0", "", "", "", "", "82.4"]} -{"pcdb_id": 9198, "brand_name": "DD Heating", "model_name": "Mikrofill", "model_qualifier": "Ethos 24 C", "winter_efficiency_pct": 79.5, "summer_efficiency_pct": 69.4, "comparative_hot_water_efficiency_pct": 48.8, "output_kw_max": 23.17, "final_year_of_manufacture": 2004, "raw": ["009198", "000215", "0", "2011/Aug/31 10:45", "Turk Demir Dokum Fab AS", "DD Heating", "Mikrofill", "Ethos 24 C", "", "2001", "2004", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "23.17", "23.17", "", "", "79.5", "69.4", "", "48.8", "", "2", "", "", "104", "1", "2", "170", "17", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.5", "79.8", "", "", "", "", "80.2"]} -{"pcdb_id": 9199, "brand_name": "Worcester", "model_name": "Greenstar 29HE Conventional", "model_qualifier": "ZB 7-29", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 29.0, "final_year_of_manufacture": 2005, "raw": ["009199", "000035", "0", "2020/Sep/04 08:04", "Worcester Heat Systems", "Worcester", "Greenstar 29HE Conventional", "ZB 7-29", "4131156", "2002", "2005", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "29", "29", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.9", "96.5", "", "", "", "", "95.1"]} -{"pcdb_id": 9200, "brand_name": "Potterton", "model_name": "Osprey 2", "model_qualifier": "CFL 180", "winter_efficiency_pct": 79.6, "summer_efficiency_pct": 69.5, "comparative_hot_water_efficiency_pct": 50.8, "output_kw_max": 52.8, "final_year_of_manufacture": 2005, "raw": ["009200", "000005", "0", "2012/Mar/27 10:12", "Baxi Potterton", "Potterton", "Osprey 2", "CFL 180", "GC No. 41-590-56", "2002", "2005", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "52.8", "52.8", "", "", "79.6", "69.5", "", "50.8", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.5", "80.8", "", "", "", "", "81.0"]} -{"pcdb_id": 9201, "brand_name": "Potterton", "model_name": "Osprey 2", "model_qualifier": "CFL 220", "winter_efficiency_pct": 78.9, "summer_efficiency_pct": 68.8, "comparative_hot_water_efficiency_pct": 50.2, "output_kw_max": 64.5, "final_year_of_manufacture": 2006, "raw": ["009201", "000005", "0", "2012/Mar/27 10:12", "Baxi Potterton", "Potterton", "Osprey 2", "CFL 220", "GC No. 41-590-57", "2002", "2006", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "64.5", "64.5", "", "", "78.9", "68.8", "", "50.2", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "80.6", "80.3", "", "", "", "", "80.3"]} -{"pcdb_id": 9202, "brand_name": "Potterton", "model_name": "Osprey 2", "model_qualifier": "CFL 150", "winter_efficiency_pct": 79.0, "summer_efficiency_pct": 68.9, "comparative_hot_water_efficiency_pct": 50.3, "output_kw_max": 43.0, "final_year_of_manufacture": 2005, "raw": ["009202", "000005", "0", "2012/Mar/27 10:12", "Baxi Potterton", "Potterton", "Osprey 2", "CFL 150", "GC No. 41-590-55", "2002", "2005", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "43", "43", "", "", "79.0", "68.9", "", "50.3", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.0", "80.2", "", "", "", "", "80.3"]} -{"pcdb_id": 9203, "brand_name": "Potterton", "model_name": "Osprey 2", "model_qualifier": "CFL 125", "winter_efficiency_pct": 79.5, "summer_efficiency_pct": 69.4, "comparative_hot_water_efficiency_pct": 50.7, "output_kw_max": 35.0, "final_year_of_manufacture": 2005, "raw": ["009203", "000005", "0", "2012/Mar/27 10:12", "Baxi Potterton", "Potterton", "Osprey 2", "CFL 125", "GC No. 41-590-54", "2002", "2005", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "35", "35", "", "", "79.5", "69.4", "", "50.7", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.3", "81.0", "", "", "", "", "81.1"]} -{"pcdb_id": 9204, "brand_name": "Potterton", "model_name": "Kingfisher Mf", "model_qualifier": "CFL 40", "winter_efficiency_pct": 79.3, "summer_efficiency_pct": 69.2, "comparative_hot_water_efficiency_pct": 50.6, "output_kw_max": 11.72, "final_year_of_manufacture": 2006, "raw": ["009204", "000005", "0", "2012/Mar/27 10:12", "Baxi Potterton", "Potterton", "Kingfisher Mf", "CFL 40", "GC No. 41-590-24", "2002", "2006", "1", "1", "1", "1", "0", "", "", "1", "1", "2", "11.72", "11.72", "", "", "79.3", "69.2", "", "50.6", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.3", "80.5", "", "", "", "", "80.7"]} -{"pcdb_id": 9205, "brand_name": "Potterton", "model_name": "Kingfisher Mf", "model_qualifier": "RSL 40", "winter_efficiency_pct": 79.4, "summer_efficiency_pct": 69.3, "comparative_hot_water_efficiency_pct": 50.7, "output_kw_max": 11.72, "final_year_of_manufacture": 2006, "raw": ["009205", "000005", "0", "2012/Mar/27 10:12", "Baxi Potterton", "Potterton", "Kingfisher Mf", "RSL 40", "GC No. 41-590-35", "2002", "2006", "1", "1", "1", "1", "0", "", "", "1", "2", "2", "11.72", "11.72", "", "", "79.4", "69.3", "", "50.7", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.2", "80.9", "", "", "", "", "81.0"]} -{"pcdb_id": 9206, "brand_name": "Baxi Potterton", "model_name": "Potterton Promax", "model_qualifier": "System HE", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 30.18, "final_year_of_manufacture": 2005, "raw": ["009206", "000005", "0", "2012/Mar/27 10:12", "Baxi Potterton", "Baxi Potterton", "Potterton Promax", "System HE", "GC No. 41-590-69", "2002", "2005", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "30.18", "30.18", "", "", "88.9", "79.9", "", "58.4", "", "2", "", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.4", "98.5", "", "", "", "", "96.8"]} -{"pcdb_id": 9207, "brand_name": "Fer Industrie", "model_name": "Falcon", "model_qualifier": "", "winter_efficiency_pct": 80.5, "summer_efficiency_pct": 70.4, "comparative_hot_water_efficiency_pct": 49.5, "output_kw_max": 23.8, "final_year_of_manufacture": null, "raw": ["009207", "000220", "0", "2006/Jan/17 12:31", "Fer Industrie", "Fer Industrie", "Falcon", "", "", "1999", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "23.8", "23.8", "", "", "80.5", "70.4", "", "49.5", "", "2", "", "", "104", "1", "2", "150", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "", "", "0004", "", "", "", "", "", "", "", "", "83.1", "80.5", "", "", "", "", "81.0"]} -{"pcdb_id": 9208, "brand_name": "Fer Industrie", "model_name": "Falcon II", "model_qualifier": "", "winter_efficiency_pct": 78.9, "summer_efficiency_pct": 68.8, "comparative_hot_water_efficiency_pct": 48.4, "output_kw_max": 30.0, "final_year_of_manufacture": null, "raw": ["009208", "000220", "0", "2006/Jan/17 12:31", "Fer Industrie", "Fer Industrie", "Falcon II", "", "", "1999", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "30", "30", "", "", "78.9", "68.8", "", "48.4", "", "2", "", "", "104", "1", "2", "150", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.5", "78.7", "", "", "", "", "79.2"]} -{"pcdb_id": 9209, "brand_name": "Ferroli", "model_name": "F30", "model_qualifier": "", "winter_efficiency_pct": 78.9, "summer_efficiency_pct": 68.8, "comparative_hot_water_efficiency_pct": 48.4, "output_kw_max": 30.0, "final_year_of_manufacture": 2006, "raw": ["009209", "000097", "0", "2009/Apr/28 16:14", "Ferroli SpA", "Ferroli", "F30", "", "", "2001", "2006", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "30", "30", "", "", "78.9", "68.8", "", "48.4", "", "2", "", "", "104", "1", "2", "150", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.5", "78.7", "", "", "", "", "79.2"]} -{"pcdb_id": 9210, "brand_name": "Ferroli", "model_name": "F24", "model_qualifier": "", "winter_efficiency_pct": 80.5, "summer_efficiency_pct": 70.4, "comparative_hot_water_efficiency_pct": 49.5, "output_kw_max": 23.8, "final_year_of_manufacture": 2006, "raw": ["009210", "000097", "0", "2009/Apr/28 16:14", "Ferroli SpA", "Ferroli", "F24", "", "", "2001", "2006", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "23.8", "23.8", "", "", "80.5", "70.4", "", "49.5", "", "2", "", "", "104", "1", "2", "150", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "83.1", "80.5", "", "", "", "", "81.0"]} -{"pcdb_id": 9211, "brand_name": "Alpha", "model_name": "CD24S", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 23.6, "final_year_of_manufacture": 2007, "raw": ["009211", "000001", "0", "2012/Mar/27 10:12", "Alpha Therm", "Alpha", "CD24S", "", "", "2002", "2007", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "23.6", "23.6", "", "", "88.1", "79.1", "", "57.7", "", "2", "", "", "102", "1", "2", "125", "2", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.3", "96.4", "", "", "", "", "95.1"]} -{"pcdb_id": 9212, "brand_name": "Alpha", "model_name": "CD24C", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 55.9, "output_kw_max": 23.6, "final_year_of_manufacture": 2007, "raw": ["009212", "000001", "0", "2011/Sep/06 13:10", "Alpha Therm", "Alpha", "CD24C", "", "", "2002", "2007", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "23.6", "23.6", "", "", "88.1", "79.5", "", "55.9", "", "2", "", "", "104", "1", "2", "130", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.3", "96.4", "", "", "", "", "95.1"]} -{"pcdb_id": 9213, "brand_name": "Alpha", "model_name": "CB50", "model_qualifier": "", "winter_efficiency_pct": 81.1, "summer_efficiency_pct": 72.0, "comparative_hot_water_efficiency_pct": 51.1, "output_kw_max": 28.0, "final_year_of_manufacture": 2005, "raw": ["009213", "000001", "0", "2024/Jan/31 10:17", "Alpha Therm", "Alpha", "CB50", "", "", "2002", "2005", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "28.0", "28.0", "", "", "81.1", "72.0", "", "51.1", "", "2", "", "", "106", "1", "2", "165", "2", "2", "2", "0", "57", "0", "50", "5", "60", "0.97", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "83.1", "80.9", "", "", "", "", "81.3"]} -{"pcdb_id": 9214, "brand_name": "Biasi", "model_name": "Garda", "model_qualifier": "M90F. 24S", "winter_efficiency_pct": 79.1, "summer_efficiency_pct": 69.0, "comparative_hot_water_efficiency_pct": 48.5, "output_kw_max": 24.3, "final_year_of_manufacture": 2007, "raw": ["009214", "000208", "0", "2008/May/22 11:39", "Biasi SpA", "Biasi", "Garda", "M90F. 24S", "47-970-19", "2002", "2007", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "24.3", "24.3", "", "", "79.1", "69.0", "", "48.5", "", "2", "", "", "104", "1", "2", "150", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.3", "78.4", "", "", "", "", "79.1"]} -{"pcdb_id": 9215, "brand_name": "Biasi", "model_name": "Garda", "model_qualifier": "M90F. 28S", "winter_efficiency_pct": 79.2, "summer_efficiency_pct": 69.1, "comparative_hot_water_efficiency_pct": 48.6, "output_kw_max": 28.4, "final_year_of_manufacture": 2007, "raw": ["009215", "000208", "0", "2008/May/22 11:38", "Biasi SpA", "Biasi", "Garda", "M90F. 28S", "47-970-20", "2002", "2007", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "28.4", "28.4", "", "", "79.2", "69.1", "", "48.6", "", "2", "", "", "104", "1", "2", "170", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.2", "78.6", "", "", "", "", "79.3"]} -{"pcdb_id": 9216, "brand_name": "Biasi", "model_name": "Garda", "model_qualifier": "M90F. 24SR", "winter_efficiency_pct": 79.3, "summer_efficiency_pct": 68.6, "comparative_hot_water_efficiency_pct": 50.1, "output_kw_max": 24.3, "final_year_of_manufacture": 2007, "raw": ["009216", "000208", "0", "2012/Mar/27 10:12", "Biasi SpA", "Biasi", "Garda", "M90F. 24SR", "41-970-10", "2002", "2007", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "24.3", "24.3", "", "", "79.3", "68.6", "", "50.1", "", "2", "", "", "102", "1", "2", "150", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.3", "78.4", "", "", "", "", "79.1"]} -{"pcdb_id": 9217, "brand_name": "Biasi", "model_name": "Garda", "model_qualifier": "M90F. 28SR", "winter_efficiency_pct": 79.4, "summer_efficiency_pct": 68.7, "comparative_hot_water_efficiency_pct": 50.2, "output_kw_max": 28.4, "final_year_of_manufacture": 2007, "raw": ["009217", "000208", "0", "2012/Mar/27 10:12", "Biasi SpA", "Biasi", "Garda", "M90F. 28SR", "41-970-11", "2002", "2007", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "28.4", "28.4", "", "", "79.4", "68.7", "", "50.2", "", "2", "", "", "102", "1", "2", "170", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.2", "78.6", "", "", "", "", "79.3"]} -{"pcdb_id": 9218, "brand_name": "Biasi", "model_name": "Riva Plus", "model_qualifier": "M90D.28SR", "winter_efficiency_pct": 79.4, "summer_efficiency_pct": 68.7, "comparative_hot_water_efficiency_pct": 50.2, "output_kw_max": 28.4, "final_year_of_manufacture": null, "raw": ["009218", "000208", "0", "2012/Mar/27 10:12", "Biasi SpA", "Biasi", "Riva Plus", "M90D.28SR", "41-970-09", "2002", "current", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "28.4", "28.4", "", "", "79.4", "68.7", "", "50.2", "", "2", "", "", "102", "1", "2", "170", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.2", "78.6", "", "", "", "", "79.3"]} -{"pcdb_id": 9219, "brand_name": "Biasi", "model_name": "Riva Plus", "model_qualifier": "M90D.28S", "winter_efficiency_pct": 79.2, "summer_efficiency_pct": 69.1, "comparative_hot_water_efficiency_pct": 48.6, "output_kw_max": 28.4, "final_year_of_manufacture": null, "raw": ["009219", "000208", "0", "2006/Jan/17 12:31", "Biasi SpA", "Biasi", "Riva Plus", "M90D.28S", "47-970-16", "2002", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "28.4", "28.4", "", "", "79.2", "69.1", "", "48.6", "", "2", "", "", "104", "1", "2", "170", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.2", "78.6", "", "", "", "", "79.3"]} -{"pcdb_id": 9220, "brand_name": "Biasi", "model_name": "Riva Plus", "model_qualifier": "M90D.24S", "winter_efficiency_pct": 79.1, "summer_efficiency_pct": 69.0, "comparative_hot_water_efficiency_pct": 48.5, "output_kw_max": 24.3, "final_year_of_manufacture": null, "raw": ["009220", "000208", "0", "2006/Jan/17 12:31", "Biasi SpA", "Biasi", "Riva Plus", "M90D.24S", "47-970-15", "2002", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "24.3", "24.3", "", "", "79.1", "69.0", "", "48.5", "", "2", "", "", "104", "1", "2", "150", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.3", "78.4", "", "", "", "", "79.1"]} -{"pcdb_id": 9221, "brand_name": "Biasi", "model_name": "Riva Plus", "model_qualifier": "M90D.24SR", "winter_efficiency_pct": 79.3, "summer_efficiency_pct": 68.6, "comparative_hot_water_efficiency_pct": 50.1, "output_kw_max": 24.3, "final_year_of_manufacture": null, "raw": ["009221", "000208", "0", "2012/Mar/27 10:12", "Biasi SpA", "Biasi", "Riva Plus", "M90D.24SR", "41-970-08", "2002", "current", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "24.3", "24.3", "", "", "79.3", "68.6", "", "50.1", "", "2", "", "", "102", "1", "2", "150", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.3", "78.4", "", "", "", "", "79.1"]} -{"pcdb_id": 9222, "brand_name": "Biasi", "model_name": "Riva Compact", "model_qualifier": "M90E.24S", "winter_efficiency_pct": 79.1, "summer_efficiency_pct": 69.0, "comparative_hot_water_efficiency_pct": 48.5, "output_kw_max": 24.3, "final_year_of_manufacture": null, "raw": ["009222", "000208", "0", "2006/Jan/17 12:31", "Biasi SpA", "Biasi", "Riva Compact", "M90E.24S", "47-970-17", "2002", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "24.3", "24.3", "", "", "79.1", "69.0", "", "48.5", "", "2", "", "", "104", "1", "2", "150", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.3", "78.4", "", "", "", "", "79.1"]} -{"pcdb_id": 9223, "brand_name": "Biasi", "model_name": "Riva Compact", "model_qualifier": "M90E.28S", "winter_efficiency_pct": 79.2, "summer_efficiency_pct": 69.1, "comparative_hot_water_efficiency_pct": 48.6, "output_kw_max": 28.4, "final_year_of_manufacture": null, "raw": ["009223", "000208", "0", "2006/Jan/17 12:31", "Biasi SpA", "Biasi", "Riva Compact", "M90E.28S", "47-970-18", "2002", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "28.4", "28.4", "", "", "79.2", "69.1", "", "48.6", "", "2", "", "", "104", "1", "2", "150", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.2", "78.6", "", "", "", "", "79.3"]} -{"pcdb_id": 9224, "brand_name": "Potterton", "model_name": "FF75", "model_qualifier": "", "winter_efficiency_pct": 79.3, "summer_efficiency_pct": 69.2, "comparative_hot_water_efficiency_pct": 50.5, "output_kw_max": 23.45, "final_year_of_manufacture": 2005, "raw": ["009224", "000005", "0", "2012/Mar/27 10:12", "Baxi Potterton", "Potterton", "FF75", "", "GC 41 590 72", "2002", "2005", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "23.45", "23.45", "", "", "79.3", "69.2", "", "50.5", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.5", "80.3", "", "", "", "", "80.5"]} -{"pcdb_id": 9225, "brand_name": "Potterton", "model_name": "FF55", "model_qualifier": "", "winter_efficiency_pct": 79.1, "summer_efficiency_pct": 69.0, "comparative_hot_water_efficiency_pct": 50.4, "output_kw_max": 17.58, "final_year_of_manufacture": 2005, "raw": ["009225", "000005", "0", "2012/Mar/27 10:12", "Baxi Potterton", "Potterton", "FF55", "", "GC 41 590 71", "2002", "2005", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "17.58", "17.58", "", "", "79.1", "69.0", "", "50.4", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.0", "80.5", "", "", "", "", "80.6"]} -{"pcdb_id": 9226, "brand_name": "Worcester", "model_name": "Bosch/British Gas RD529", "model_qualifier": "ZWB 7-29 A", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 55.9, "output_kw_max": 29.2, "final_year_of_manufacture": 2003, "raw": ["009226", "000035", "0", "2003/Jun/17 12:53", "Worcester Heat Systems", "Worcester", "Bosch/British Gas RD529", "ZWB 7-29 A", "47 108 09", "2002", "2003", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "29.2", "29.2", "", "", "88.1", "79.5", "", "55.9", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.9", "96.8", "", "", "", "", "95.3"]} -{"pcdb_id": 9227, "brand_name": "Worcester", "model_name": "26 CDi Xtra", "model_qualifier": "RSF - L", "winter_efficiency_pct": 85.8, "summer_efficiency_pct": 77.2, "comparative_hot_water_efficiency_pct": 54.3, "output_kw_max": 26.0, "final_year_of_manufacture": 2005, "raw": ["009227", "000035", "0", "2020/Sep/04 08:04", "Worcester Heat Systems", "Worcester", "26 CDi Xtra", "RSF - L", "47 311 41", "1998", "2005", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "26", "26", "", "", "85.8", "77.2", "", "54.3", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "86.6", "91.7", "", "", "", "", "90.7"]} -{"pcdb_id": 9228, "brand_name": "Keston", "model_name": "K", "model_qualifier": "40", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 44.9, "final_year_of_manufacture": null, "raw": ["009228", "000022", "0", "2012/Mar/27 10:12", "Keston Boilers", "Keston", "K", "40", "C40", "2002", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "44.9", "44.9", "", "", "88.6", "79.6", "", "58.1", "", "2", "", "", "102", "1", "2", "260", "8", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.5", "98.0", "", "", "", "", "96.2"]} -{"pcdb_id": 9229, "brand_name": "Keston", "model_name": "K", "model_qualifier": "55", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 55.2, "final_year_of_manufacture": null, "raw": ["009229", "000022", "0", "2012/Mar/27 10:12", "Keston Boilers", "Keston", "K", "55", "C55", "2002", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "55.2", "55.2", "", "", "89.0", "80.0", "", "58.5", "", "2", "", "", "102", "1", "2", "260", "8", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "99.5", "", "", "", "", "97.3"]} -{"pcdb_id": 9231, "brand_name": "Merlin", "model_name": "2000", "model_qualifier": "80/100 BL", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 29.3, "final_year_of_manufacture": null, "raw": ["009231", "000210", "0", "2012/Mar/27 10:12", "BH Associates", "Merlin", "2000", "80/100 BL", "", "1999", "current", "4", "1", "1", "1", "0", "", "", "1", "2", "1", "23.4", "29.3", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.5", "87.4", "", "", "", "", "87.4"]} -{"pcdb_id": 9232, "brand_name": "Merlin", "model_name": "2000", "model_qualifier": "80/100 CF", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 29.3, "final_year_of_manufacture": null, "raw": ["009232", "000210", "0", "2012/Mar/27 10:12", "BH Associates", "Merlin", "2000", "80/100 CF", "", "1999", "current", "4", "1", "1", "1", "0", "", "", "1", "1", "1", "23.4", "29.3", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.5", "87.4", "", "", "", "", "87.4"]} -{"pcdb_id": 9233, "brand_name": "Merlin", "model_name": "2000", "model_qualifier": "60/80 CF", "winter_efficiency_pct": 86.6, "summer_efficiency_pct": 74.9, "comparative_hot_water_efficiency_pct": 54.7, "output_kw_max": 23.4, "final_year_of_manufacture": null, "raw": ["009233", "000210", "0", "2012/Mar/27 10:12", "BH Associates", "Merlin", "2000", "60/80 CF", "", "1999", "current", "4", "1", "1", "1", "0", "", "", "1", "1", "1", "17.6", "23.4", "", "", "86.6", "74.9", "", "54.7", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.3", "87.0", "", "", "", "", "87.1"]} -{"pcdb_id": 9234, "brand_name": "Merlin", "model_name": "2000", "model_qualifier": "60/80 BL", "winter_efficiency_pct": 86.6, "summer_efficiency_pct": 74.9, "comparative_hot_water_efficiency_pct": 54.7, "output_kw_max": 23.4, "final_year_of_manufacture": null, "raw": ["009234", "000210", "0", "2012/Mar/27 10:12", "BH Associates", "Merlin", "2000", "60/80 BL", "", "1999", "current", "4", "1", "1", "1", "0", "", "", "1", "2", "1", "17.6", "23.4", "", "", "86.6", "74.9", "", "54.7", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.3", "87.0", "", "", "", "", "87.1"]} -{"pcdb_id": 9235, "brand_name": "Merlin", "model_name": "2000", "model_qualifier": "40/60 CF", "winter_efficiency_pct": 86.4, "summer_efficiency_pct": 74.7, "comparative_hot_water_efficiency_pct": 54.6, "output_kw_max": 17.6, "final_year_of_manufacture": null, "raw": ["009235", "000210", "0", "2012/Mar/27 10:12", "BH Associates", "Merlin", "2000", "40/60 CF", "", "1999", "current", "4", "1", "1", "1", "0", "", "", "1", "1", "1", "11.7", "17.6", "", "", "86.4", "74.7", "", "54.6", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.0", "86.7", "", "", "", "", "86.7"]} -{"pcdb_id": 9236, "brand_name": "Merlin", "model_name": "2000", "model_qualifier": "40/60 BL", "winter_efficiency_pct": 86.4, "summer_efficiency_pct": 74.7, "comparative_hot_water_efficiency_pct": 54.6, "output_kw_max": 17.6, "final_year_of_manufacture": null, "raw": ["009236", "000210", "0", "2012/Mar/27 10:12", "BH Associates", "Merlin", "2000", "40/60 BL", "", "1999", "current", "4", "1", "1", "1", "0", "", "", "1", "2", "1", "11.7", "17.6", "", "", "86.4", "74.7", "", "54.6", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.0", "86.7", "", "", "", "", "86.7"]} -{"pcdb_id": 9237, "brand_name": "Heating World Group", "model_name": "Grandee 2S 18/22 BF EXT", "model_qualifier": "", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 22.0, "final_year_of_manufacture": null, "raw": ["009237", "000050", "0", "2012/Mar/27 10:12", "Heating World Group", "Heating World Group", "Grandee 2S 18/22 BF EXT", "", "", "1993", "current", "4", "2", "2", "1", "0", "", "", "1", "2", "2", "18", "22", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.0", "87.7", "", "", "", "", "87.6"]} -{"pcdb_id": 9238, "brand_name": "Heating World Group", "model_name": "Grandee 2S 18/22 BF", "model_qualifier": "", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 22.0, "final_year_of_manufacture": null, "raw": ["009238", "000050", "0", "2012/Mar/27 10:12", "Heating World Group", "Heating World Group", "Grandee 2S 18/22 BF", "", "", "1993", "current", "4", "2", "2", "1", "0", "", "", "1", "2", "2", "18", "22", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.0", "87.7", "", "", "", "", "87.6"]} -{"pcdb_id": 9239, "brand_name": "Heating World Group", "model_name": "Grandee 2S 18/22 CF", "model_qualifier": "", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 22.0, "final_year_of_manufacture": null, "raw": ["009239", "000050", "0", "2012/Mar/27 10:12", "Heating World Group", "Heating World Group", "Grandee 2S 18/22 CF", "", "", "1993", "current", "4", "2", "2", "1", "0", "", "", "1", "1", "2", "18", "22", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.0", "87.7", "", "", "", "", "87.6"]} -{"pcdb_id": 9240, "brand_name": "Heating World Group", "model_name": "Grandee 3S 22/27 BF", "model_qualifier": "", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 27.0, "final_year_of_manufacture": null, "raw": ["009240", "000050", "0", "2012/Mar/27 10:12", "Heating World Group", "Heating World Group", "Grandee 3S 22/27 BF", "", "", "1993", "current", "4", "2", "2", "1", "0", "", "", "1", "2", "2", "22", "27", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.4", "87.2", "", "", "", "", "87.1"]} -{"pcdb_id": 9241, "brand_name": "Heating World Group", "model_name": "Grandee 3S 22/27 CF", "model_qualifier": "", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 27.0, "final_year_of_manufacture": null, "raw": ["009241", "000050", "0", "2012/Mar/27 10:12", "Heating World Group", "Heating World Group", "Grandee 3S 22/27 CF", "", "", "1993", "current", "4", "2", "2", "1", "0", "", "", "1", "1", "2", "22", "27", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.4", "87.2", "", "", "", "", "87.1"]} -{"pcdb_id": 9242, "brand_name": "Heating World Group", "model_name": "Grandee 3S 22/27 BF EXT", "model_qualifier": "", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 27.0, "final_year_of_manufacture": null, "raw": ["009242", "000050", "0", "2012/Mar/27 10:12", "Heating World Group", "Heating World Group", "Grandee 3S 22/27 BF EXT", "", "", "1993", "current", "4", "2", "2", "1", "0", "", "", "1", "2", "2", "22", "27", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.4", "87.2", "", "", "", "", "87.1"]} -{"pcdb_id": 9243, "brand_name": "Heating World Group", "model_name": "Grandee 5S 12/18 CF", "model_qualifier": "", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 18.0, "final_year_of_manufacture": null, "raw": ["009243", "000050", "0", "2012/Mar/27 10:12", "Heating World Group", "Heating World Group", "Grandee 5S 12/18 CF", "", "", "1993", "current", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "12", "18", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.4", "88.2", "", "", "", "", "88.0"]} -{"pcdb_id": 9244, "brand_name": "Heating World Group", "model_name": "Grandee 5S 12/18 BF", "model_qualifier": "", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 18.0, "final_year_of_manufacture": null, "raw": ["009244", "000050", "0", "2012/Mar/27 10:12", "Heating World Group", "Heating World Group", "Grandee 5S 12/18 BF", "", "", "1993", "current", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "12", "18", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.4", "88.2", "", "", "", "", "88.0"]} -{"pcdb_id": 9245, "brand_name": "Heating World Group", "model_name": "Grandee 1S 12/18 CF", "model_qualifier": "", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 18.0, "final_year_of_manufacture": null, "raw": ["009245", "000050", "0", "2012/Mar/27 10:12", "Heating World Group", "Heating World Group", "Grandee 1S 12/18 CF", "", "", "1993", "current", "4", "2", "2", "1", "0", "", "", "1", "1", "2", "12", "18", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.4", "88.2", "", "", "", "", "88.0"]} -{"pcdb_id": 9246, "brand_name": "Heating World Group", "model_name": "Grandee 1S 12/18 BF EXT", "model_qualifier": "", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 18.0, "final_year_of_manufacture": null, "raw": ["009246", "000050", "0", "2012/Mar/27 10:12", "Heating World Group", "Heating World Group", "Grandee 1S 12/18 BF EXT", "", "", "1993", "current", "4", "2", "2", "1", "0", "", "", "1", "2", "2", "12", "18", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.4", "88.2", "", "", "", "", "88.0"]} -{"pcdb_id": 9247, "brand_name": "Heating World Group", "model_name": "Sorrento SHI 12/18 BF", "model_qualifier": "", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 18.0, "final_year_of_manufacture": null, "raw": ["009247", "000050", "0", "2012/Mar/27 10:12", "Heating World Group", "Heating World Group", "Sorrento SHI 12/18 BF", "", "", "1993", "current", "4", "4", "1", "1", "0", "", "", "1", "2", "2", "12", "18", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.4", "88.2", "", "", "", "", "88.0"]} -{"pcdb_id": 9248, "brand_name": "Heating World Group", "model_name": "Sorrento SHI 12/18 CF", "model_qualifier": "", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 18.0, "final_year_of_manufacture": null, "raw": ["009248", "000050", "0", "2012/Mar/27 10:12", "Heating World Group", "Heating World Group", "Sorrento SHI 12/18 CF", "", "", "1993", "current", "4", "4", "1", "1", "0", "", "", "1", "1", "2", "12", "18", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.4", "88.2", "", "", "", "", "88.0"]} -{"pcdb_id": 9249, "brand_name": "Heating World Group", "model_name": "Sorrento SFS 12/18 CF", "model_qualifier": "", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 18.0, "final_year_of_manufacture": null, "raw": ["009249", "000050", "0", "2012/Mar/27 10:12", "Heating World Group", "Heating World Group", "Sorrento SFS 12/18 CF", "", "", "1993", "current", "4", "4", "1", "1", "0", "", "", "1", "1", "2", "12", "18", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.4", "88.2", "", "", "", "", "88.0"]} -{"pcdb_id": 9250, "brand_name": "Heating World Group", "model_name": "Sorrento SFS 12/18 BF", "model_qualifier": "", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 18.0, "final_year_of_manufacture": null, "raw": ["009250", "000050", "0", "2012/Mar/27 10:12", "Heating World Group", "Heating World Group", "Sorrento SFS 12/18 BF", "", "", "1993", "current", "4", "4", "1", "1", "0", "", "", "1", "2", "2", "12", "18", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.4", "88.2", "", "", "", "", "88.0"]} -{"pcdb_id": 9251, "brand_name": "Heating World Group", "model_name": "Flamevector SHI 12/18 BF", "model_qualifier": "", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 18.0, "final_year_of_manufacture": null, "raw": ["009251", "000050", "0", "2012/Mar/27 10:12", "Heating World Group", "Heating World Group", "Flamevector SHI 12/18 BF", "", "", "1993", "current", "4", "4", "1", "1", "0", "", "", "1", "2", "2", "12", "18", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.4", "88.2", "", "", "", "", "88.0"]} -{"pcdb_id": 9252, "brand_name": "Heating World Group", "model_name": "Flamevector SHI 12/18 CF", "model_qualifier": "", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 18.0, "final_year_of_manufacture": null, "raw": ["009252", "000050", "0", "2012/Mar/27 10:12", "Heating World Group", "Heating World Group", "Flamevector SHI 12/18 CF", "", "", "1993", "current", "4", "4", "1", "1", "0", "", "", "1", "1", "2", "12", "18", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.4", "88.2", "", "", "", "", "88.0"]} -{"pcdb_id": 9253, "brand_name": "Heating World Group", "model_name": "Flamevector SHFS 12/18 BF", "model_qualifier": "", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 18.0, "final_year_of_manufacture": null, "raw": ["009253", "000050", "0", "2012/Mar/27 10:12", "Heating World Group", "Heating World Group", "Flamevector SHFS 12/18 BF", "", "", "1993", "current", "4", "4", "1", "1", "0", "", "", "1", "2", "2", "12", "18", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.4", "88.2", "", "", "", "", "88.0"]} -{"pcdb_id": 9254, "brand_name": "Heating World Group", "model_name": "Flamevector SHFS 12/18 CF", "model_qualifier": "", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 18.0, "final_year_of_manufacture": null, "raw": ["009254", "000050", "0", "2012/Mar/27 10:12", "Heating World Group", "Heating World Group", "Flamevector SHFS 12/18 CF", "", "", "1993", "current", "4", "4", "1", "1", "0", "", "", "1", "1", "2", "12", "18", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.4", "88.2", "", "", "", "", "88.0"]} -{"pcdb_id": 9255, "brand_name": "Heating World Group", "model_name": "Grandee Combi SW 15/20 BF", "model_qualifier": "", "winter_efficiency_pct": 83.8, "summer_efficiency_pct": 74.3, "comparative_hot_water_efficiency_pct": 52.2, "output_kw_max": 20.0, "final_year_of_manufacture": null, "raw": ["009255", "000050", "0", "2002/Jul/30 10:47", "Heating World Group", "Heating World Group", "Grandee Combi SW 15/20 BF", "", "", "1998", "current", "4", "2", "2", "2", "0", "", "", "1", "2", "2", "15", "20", "", "", "83.8", "74.3", "", "52.2", "", "2", "", "", "202", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.7", "85.0", "", "", "", "", "85.3"]} -{"pcdb_id": 9256, "brand_name": "Heating World Group", "model_name": "Grandee Combi SW 15/20 CF", "model_qualifier": "", "winter_efficiency_pct": 83.8, "summer_efficiency_pct": 74.3, "comparative_hot_water_efficiency_pct": 52.2, "output_kw_max": 20.0, "final_year_of_manufacture": null, "raw": ["009256", "000050", "0", "2002/Jul/30 10:47", "Heating World Group", "Heating World Group", "Grandee Combi SW 15/20 CF", "", "", "1998", "current", "4", "2", "2", "2", "0", "", "", "1", "1", "2", "15", "20", "", "", "83.8", "74.3", "", "52.2", "", "2", "", "", "202", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.7", "85.0", "", "", "", "", "85.3"]} -{"pcdb_id": 9257, "brand_name": "Heating World Group", "model_name": "Grandee Combi SW 20/24 BF", "model_qualifier": "", "winter_efficiency_pct": 84.4, "summer_efficiency_pct": 74.9, "comparative_hot_water_efficiency_pct": 52.6, "output_kw_max": 24.0, "final_year_of_manufacture": null, "raw": ["009257", "000050", "0", "2002/Jul/30 10:47", "Heating World Group", "Heating World Group", "Grandee Combi SW 20/24 BF", "", "", "1998", "current", "4", "2", "2", "2", "0", "", "", "1", "2", "2", "20", "24", "", "", "84.4", "74.9", "", "52.6", "", "2", "", "", "202", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.6", "86.1", "", "", "", "", "86.2"]} -{"pcdb_id": 9258, "brand_name": "Heating World Group", "model_name": "Grandee Combi SW 20/24 CF", "model_qualifier": "", "winter_efficiency_pct": 84.4, "summer_efficiency_pct": 74.9, "comparative_hot_water_efficiency_pct": 52.6, "output_kw_max": 20.0, "final_year_of_manufacture": null, "raw": ["009258", "000050", "0", "2002/Jul/30 10:48", "Heating World Group", "Heating World Group", "Grandee Combi SW 20/24 CF", "", "", "1998", "current", "4", "2", "2", "2", "0", "", "", "1", "1", "2", "15", "20", "", "", "84.4", "74.9", "", "52.6", "", "2", "", "", "202", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.6", "86.1", "", "", "", "", "86.2"]} -{"pcdb_id": 9259, "brand_name": "Heating World Group", "model_name": "Grandee Combi SW 24/27 BF", "model_qualifier": "", "winter_efficiency_pct": 84.9, "summer_efficiency_pct": 75.4, "comparative_hot_water_efficiency_pct": 53.0, "output_kw_max": 27.0, "final_year_of_manufacture": null, "raw": ["009259", "000050", "0", "2002/Jul/30 10:49", "Heating World Group", "Heating World Group", "Grandee Combi SW 24/27 BF", "", "", "1998", "current", "4", "2", "2", "2", "0", "", "", "1", "2", "2", "24", "27", "", "", "84.9", "75.4", "", "53.0", "", "2", "", "", "202", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.4", "87.2", "", "", "", "", "87.1"]} -{"pcdb_id": 9260, "brand_name": "Heating World Group", "model_name": "Grandee Combi SW 24/27 CF", "model_qualifier": "", "winter_efficiency_pct": 84.9, "summer_efficiency_pct": 75.4, "comparative_hot_water_efficiency_pct": 53.0, "output_kw_max": 27.0, "final_year_of_manufacture": null, "raw": ["009260", "000050", "0", "2002/Jul/30 10:49", "Heating World Group", "Heating World Group", "Grandee Combi SW 24/27 CF", "", "", "1998", "current", "4", "2", "2", "2", "0", "", "", "1", "1", "2", "24", "27", "", "", "84.9", "75.4", "", "53.0", "", "2", "", "", "202", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.4", "87.2", "", "", "", "", "87.1"]} -{"pcdb_id": 9261, "brand_name": "Heating World Group", "model_name": "Grandee Combi SFS 25/29 BF", "model_qualifier": "", "winter_efficiency_pct": 84.5, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 52.8, "output_kw_max": 29.0, "final_year_of_manufacture": null, "raw": ["009261", "000050", "0", "2002/Jul/30 10:50", "Heating World Group", "Heating World Group", "Grandee Combi SFS 25/29 BF", "", "", "1998", "current", "4", "1", "1", "2", "0", "", "", "1", "2", "2", "25", "29", "", "", "84.5", "75.0", "", "52.8", "", "2", "", "", "202", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.1", "86.6", "", "", "", "", "86.5"]} -{"pcdb_id": 9262, "brand_name": "Heating World Group", "model_name": "Grandee Combi SFS 25/29 CF", "model_qualifier": "", "winter_efficiency_pct": 84.5, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 52.8, "output_kw_max": 29.0, "final_year_of_manufacture": null, "raw": ["009262", "000050", "0", "2002/Jul/30 10:24", "Heating World Group", "Heating World Group", "Grandee Combi SFS 25/29 CF", "", "", "1998", "current", "4", "1", "1", "2", "0", "", "", "1", "1", "2", "25", "29", "", "", "84.5", "75.0", "", "52.8", "", "2", "", "", "202", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.1", "86.6", "", "", "", "", "86.5"]} -{"pcdb_id": 9263, "brand_name": "Heating World Group", "model_name": "Grandee Combi SFS 20/25 BF", "model_qualifier": "", "winter_efficiency_pct": 84.2, "summer_efficiency_pct": 74.7, "comparative_hot_water_efficiency_pct": 52.5, "output_kw_max": 25.0, "final_year_of_manufacture": null, "raw": ["009263", "000050", "0", "2002/Jul/30 10:25", "Heating World Group", "Heating World Group", "Grandee Combi SFS 20/25 BF", "", "", "1998", "current", "4", "1", "1", "2", "0", "", "", "1", "2", "2", "20", "25", "", "", "84.2", "74.7", "", "52.5", "", "2", "", "", "202", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.4", "85.8", "", "", "", "", "85.9"]} -{"pcdb_id": 9264, "brand_name": "Heating World Group", "model_name": "Grandee Combi SFS 20/25 CF", "model_qualifier": "", "winter_efficiency_pct": 84.2, "summer_efficiency_pct": 74.7, "comparative_hot_water_efficiency_pct": 52.5, "output_kw_max": 25.0, "final_year_of_manufacture": null, "raw": ["009264", "000050", "0", "2002/Jul/30 10:25", "Heating World Group", "Heating World Group", "Grandee Combi SFS 20/25 CF", "", "", "1998", "current", "4", "1", "1", "2", "0", "", "", "1", "1", "2", "20", "25", "", "", "84.2", "74.7", "", "52.5", "", "2", "", "", "202", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.4", "85.8", "", "", "", "", "85.9"]} -{"pcdb_id": 9265, "brand_name": "Heating World Group", "model_name": "Grandee Combi SFS 15/20 CF", "model_qualifier": "", "winter_efficiency_pct": 83.6, "summer_efficiency_pct": 74.1, "comparative_hot_water_efficiency_pct": 52.1, "output_kw_max": 20.0, "final_year_of_manufacture": null, "raw": ["009265", "000050", "0", "2002/Jul/30 10:26", "Heating World Group", "Heating World Group", "Grandee Combi SFS 15/20 CF", "", "", "1998", "current", "4", "1", "1", "2", "0", "", "", "1", "1", "2", "15", "20", "", "", "83.6", "74.1", "", "52.1", "", "2", "", "", "202", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.2", "84.5", "", "", "", "", "85.0"]} -{"pcdb_id": 9266, "brand_name": "Heating World Group", "model_name": "Grandee Combi SFS 15/20 BF", "model_qualifier": "", "winter_efficiency_pct": 83.6, "summer_efficiency_pct": 74.1, "comparative_hot_water_efficiency_pct": 52.1, "output_kw_max": 20.0, "final_year_of_manufacture": null, "raw": ["009266", "000050", "0", "2002/Jul/30 10:26", "Heating World Group", "Heating World Group", "Grandee Combi SFS 15/20 BF", "", "", "1998", "current", "4", "1", "1", "2", "0", "", "", "1", "2", "2", "15", "20", "", "", "83.6", "74.1", "", "52.1", "", "2", "", "", "202", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.2", "84.5", "", "", "", "", "85.0"]} -{"pcdb_id": 9267, "brand_name": "Heating World Group", "model_name": "Grandee 1S 12/18 BF", "model_qualifier": "", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 18.0, "final_year_of_manufacture": null, "raw": ["009267", "000050", "0", "2012/Mar/27 10:12", "Heating World Group", "Heating World Group", "Grandee 1S 12/18 BF", "", "", "1993", "current", "4", "2", "2", "1", "0", "", "", "1", "2", "2", "12", "18", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.4", "88.2", "", "", "", "", "88.0"]} -{"pcdb_id": 9268, "brand_name": "Heating World Group", "model_name": "Grandee Combi Compact", "model_qualifier": "SFS 15/20 BF", "winter_efficiency_pct": 83.6, "summer_efficiency_pct": 74.1, "comparative_hot_water_efficiency_pct": 52.1, "output_kw_max": 20.0, "final_year_of_manufacture": null, "raw": ["009268", "000050", "0", "2002/Jul/30 10:26", "Heating World Group", "Heating World Group", "Grandee Combi Compact", "SFS 15/20 BF", "", "1997", "current", "4", "1", "1", "2", "0", "", "", "1", "2", "1", "15", "20", "", "", "83.6", "74.1", "", "52.1", "", "2", "", "", "202", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "0", "", "0002", "", "", "", "", "", "", "", "", "87.2", "84.5", "", "", "", "", "85.0"]} -{"pcdb_id": 9269, "brand_name": "Heating World Group", "model_name": "Grandee Combi Compact", "model_qualifier": "SFS 15-20 CF", "winter_efficiency_pct": 83.6, "summer_efficiency_pct": 74.1, "comparative_hot_water_efficiency_pct": 52.1, "output_kw_max": 20.0, "final_year_of_manufacture": null, "raw": ["009269", "000050", "0", "2002/Jul/30 10:27", "Heating World Group", "Heating World Group", "Grandee Combi Compact", "SFS 15-20 CF", "", "1997", "current", "4", "1", "1", "2", "0", "", "", "1", "1", "1", "15", "20", "", "", "83.6", "74.1", "", "52.1", "", "2", "", "", "202", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "0", "", "0002", "", "", "", "", "", "", "", "", "87.2", "84.5", "", "", "", "", "85.0"]} -{"pcdb_id": 9270, "brand_name": "Heating World Group", "model_name": "Grandee", "model_qualifier": "9S 40/50 CF", "winter_efficiency_pct": 85.6, "summer_efficiency_pct": 73.9, "comparative_hot_water_efficiency_pct": 54.0, "output_kw_max": 44.0, "final_year_of_manufacture": null, "raw": ["009270", "000050", "0", "2012/Mar/27 10:12", "Heating World Group", "Heating World Group", "Grandee", "9S 40/50 CF", "", "1997", "current", "4", "1", "1", "1", "0", "", "", "1", "1", "1", "44", "44", "", "", "85.6", "73.9", "", "54.0", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.7", "85.0", "", "", "", "", "85.3"]} -{"pcdb_id": 9271, "brand_name": "Heating World Group", "model_name": "Grandee", "model_qualifier": "9S 40/50 BF", "winter_efficiency_pct": 85.6, "summer_efficiency_pct": 73.9, "comparative_hot_water_efficiency_pct": 54.0, "output_kw_max": 44.0, "final_year_of_manufacture": null, "raw": ["009271", "000050", "0", "2012/Mar/27 10:12", "Heating World Group", "Heating World Group", "Grandee", "9S 40/50 BF", "", "1997", "current", "4", "1", "1", "1", "0", "", "", "1", "2", "1", "44", "44", "", "", "85.6", "73.9", "", "54.0", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.7", "85.0", "", "", "", "", "85.3"]} -{"pcdb_id": 9272, "brand_name": "Heating World Group", "model_name": "Grandee", "model_qualifier": "8S 35/40 BF", "winter_efficiency_pct": 85.6, "summer_efficiency_pct": 73.9, "comparative_hot_water_efficiency_pct": 54.0, "output_kw_max": 40.0, "final_year_of_manufacture": null, "raw": ["009272", "000050", "0", "2012/Mar/27 10:12", "Heating World Group", "Heating World Group", "Grandee", "8S 35/40 BF", "", "1997", "current", "4", "1", "1", "1", "0", "", "", "1", "2", "1", "40", "40", "", "", "85.6", "73.9", "", "54.0", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.7", "85.0", "", "", "", "", "85.3"]} -{"pcdb_id": 9273, "brand_name": "Heating World Group", "model_name": "Grandee", "model_qualifier": "8S 35/40 CF", "winter_efficiency_pct": 85.6, "summer_efficiency_pct": 73.9, "comparative_hot_water_efficiency_pct": 54.0, "output_kw_max": 40.0, "final_year_of_manufacture": null, "raw": ["009273", "000050", "0", "2012/Mar/27 10:12", "Heating World Group", "Heating World Group", "Grandee", "8S 35/40 CF", "", "1997", "current", "4", "1", "1", "1", "0", "", "", "1", "1", "1", "40", "40", "", "", "85.6", "73.9", "", "54.0", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.7", "85.0", "", "", "", "", "85.3"]} -{"pcdb_id": 9274, "brand_name": "Heating World Group", "model_name": "Grandee", "model_qualifier": "6S 15/23 BF", "winter_efficiency_pct": 85.6, "summer_efficiency_pct": 73.9, "comparative_hot_water_efficiency_pct": 54.0, "output_kw_max": 23.0, "final_year_of_manufacture": null, "raw": ["009274", "000050", "0", "2012/Mar/27 10:12", "Heating World Group", "Heating World Group", "Grandee", "6S 15/23 BF", "", "1997", "current", "4", "1", "1", "1", "0", "", "", "1", "2", "1", "23", "23", "", "", "85.6", "73.9", "", "54.0", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.7", "85.0", "", "", "", "", "85.3"]} -{"pcdb_id": 9275, "brand_name": "Heating World Group", "model_name": "Grandee", "model_qualifier": "6S 15/23 CF", "winter_efficiency_pct": 85.6, "summer_efficiency_pct": 73.9, "comparative_hot_water_efficiency_pct": 54.0, "output_kw_max": 23.0, "final_year_of_manufacture": null, "raw": ["009275", "000050", "0", "2012/Mar/27 10:12", "Heating World Group", "Heating World Group", "Grandee", "6S 15/23 CF", "", "1997", "current", "4", "1", "1", "1", "0", "", "", "1", "1", "1", "23", "23", "", "", "85.6", "73.9", "", "54.0", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.7", "85.0", "", "", "", "", "85.3"]} -{"pcdb_id": 9276, "brand_name": "Heating World Group", "model_name": "Grandee", "model_qualifier": "7S 26/32 BF", "winter_efficiency_pct": 85.6, "summer_efficiency_pct": 73.9, "comparative_hot_water_efficiency_pct": 54.0, "output_kw_max": 29.0, "final_year_of_manufacture": null, "raw": ["009276", "000050", "0", "2012/Mar/27 10:12", "Heating World Group", "Heating World Group", "Grandee", "7S 26/32 BF", "", "1997", "current", "4", "1", "1", "1", "0", "", "", "1", "2", "1", "29", "29", "", "", "85.6", "73.9", "", "54.0", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.7", "85.0", "", "", "", "", "85.3"]} -{"pcdb_id": 9277, "brand_name": "Heating World Group", "model_name": "Grandee", "model_qualifier": "7S 26/32 CF", "winter_efficiency_pct": 85.6, "summer_efficiency_pct": 73.9, "comparative_hot_water_efficiency_pct": 54.0, "output_kw_max": 29.0, "final_year_of_manufacture": null, "raw": ["009277", "000050", "0", "2012/Mar/27 10:12", "Heating World Group", "Heating World Group", "Grandee", "7S 26/32 CF", "", "1997", "current", "4", "1", "1", "1", "0", "", "", "1", "1", "1", "29", "29", "", "", "85.6", "73.9", "", "54.0", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.7", "85.0", "", "", "", "", "85.3"]} -{"pcdb_id": 9278, "brand_name": "Heating World Group", "model_name": "Flamevector", "model_qualifier": "SHFS 18/21 BF", "winter_efficiency_pct": 83.6, "summer_efficiency_pct": 71.9, "comparative_hot_water_efficiency_pct": 52.5, "output_kw_max": 18.0, "final_year_of_manufacture": null, "raw": ["009278", "000050", "0", "2012/Mar/27 10:12", "Heating World Group", "Heating World Group", "Flamevector", "SHFS 18/21 BF", "", "1997", "current", "4", "1", "1", "1", "0", "", "", "1", "1", "1", "18", "18", "", "", "83.6", "71.9", "", "52.5", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.3", "84.9", "", "", "", "", "84.4"]} -{"pcdb_id": 9279, "brand_name": "Heating World Group", "model_name": "Flamevector", "model_qualifier": "SHFS 18/21 CF", "winter_efficiency_pct": 83.6, "summer_efficiency_pct": 71.9, "comparative_hot_water_efficiency_pct": 52.5, "output_kw_max": 18.0, "final_year_of_manufacture": null, "raw": ["009279", "000050", "0", "2012/Mar/27 10:12", "Heating World Group", "Heating World Group", "Flamevector", "SHFS 18/21 CF", "", "1997", "current", "4", "1", "1", "1", "0", "", "", "1", "1", "1", "18", "18", "", "", "83.6", "71.9", "", "52.5", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.3", "84.9", "", "", "", "", "84.4"]} -{"pcdb_id": 9280, "brand_name": "Heating World Group", "model_name": "Flamevector", "model_qualifier": "SHI 18/21 BF", "winter_efficiency_pct": 83.6, "summer_efficiency_pct": 71.9, "comparative_hot_water_efficiency_pct": 52.5, "output_kw_max": 18.0, "final_year_of_manufacture": null, "raw": ["009280", "000050", "0", "2012/Mar/27 10:12", "Heating World Group", "Heating World Group", "Flamevector", "SHI 18/21 BF", "", "1997", "current", "4", "1", "1", "1", "0", "", "", "1", "1", "1", "18", "18", "", "", "83.6", "71.9", "", "52.5", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.3", "84.9", "", "", "", "", "84.4"]} -{"pcdb_id": 9281, "brand_name": "Heating World Group", "model_name": "Flamevector", "model_qualifier": "SHI 18/21 CF", "winter_efficiency_pct": 83.6, "summer_efficiency_pct": 71.9, "comparative_hot_water_efficiency_pct": 52.5, "output_kw_max": 18.0, "final_year_of_manufacture": null, "raw": ["009281", "000050", "0", "2012/Mar/27 10:12", "Heating World Group", "Heating World Group", "Flamevector", "SHI 18/21 CF", "", "1997", "current", "4", "1", "1", "1", "0", "", "", "1", "1", "1", "18", "18", "", "", "83.6", "71.9", "", "52.5", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.3", "84.9", "", "", "", "", "84.4"]} -{"pcdb_id": 9282, "brand_name": "Heating World Group", "model_name": "Sorrento", "model_qualifier": "SFS 18/21 CF", "winter_efficiency_pct": 83.6, "summer_efficiency_pct": 71.9, "comparative_hot_water_efficiency_pct": 52.5, "output_kw_max": 18.0, "final_year_of_manufacture": null, "raw": ["009282", "000050", "0", "2012/Mar/27 10:12", "Heating World Group", "Heating World Group", "Sorrento", "SFS 18/21 CF", "", "1997", "current", "4", "1", "1", "1", "0", "", "", "1", "1", "1", "18", "18", "", "", "83.6", "71.9", "", "52.5", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.3", "84.9", "", "", "", "", "84.4"]} -{"pcdb_id": 9283, "brand_name": "Heating World Group", "model_name": "Sorrento", "model_qualifier": "SFS 18/21 BF", "winter_efficiency_pct": 83.6, "summer_efficiency_pct": 71.9, "comparative_hot_water_efficiency_pct": 52.5, "output_kw_max": 18.0, "final_year_of_manufacture": null, "raw": ["009283", "000050", "0", "2012/Mar/27 10:12", "Heating World Group", "Heating World Group", "Sorrento", "SFS 18/21 BF", "", "1997", "current", "4", "1", "1", "1", "0", "", "", "1", "1", "1", "18", "18", "", "", "83.6", "71.9", "", "52.5", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.3", "84.9", "", "", "", "", "84.4"]} -{"pcdb_id": 9284, "brand_name": "Heating World Group", "model_name": "Sorrento", "model_qualifier": "SHI 18/21 BF", "winter_efficiency_pct": 83.6, "summer_efficiency_pct": 71.9, "comparative_hot_water_efficiency_pct": 52.5, "output_kw_max": 18.0, "final_year_of_manufacture": null, "raw": ["009284", "000050", "0", "2012/Mar/27 10:12", "Heating World Group", "Heating World Group", "Sorrento", "SHI 18/21 BF", "", "1997", "current", "4", "1", "1", "1", "0", "", "", "1", "1", "1", "18", "18", "", "", "83.6", "71.9", "", "52.5", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.3", "84.9", "", "", "", "", "84.4"]} -{"pcdb_id": 9285, "brand_name": "Heating World Group", "model_name": "Sorrento", "model_qualifier": "SHI 18/21 CF", "winter_efficiency_pct": 83.6, "summer_efficiency_pct": 71.9, "comparative_hot_water_efficiency_pct": 52.5, "output_kw_max": 18.0, "final_year_of_manufacture": null, "raw": ["009285", "000050", "0", "2012/Mar/27 10:12", "Heating World Group", "Heating World Group", "Sorrento", "SHI 18/21 CF", "", "1997", "current", "4", "1", "1", "1", "0", "", "", "1", "1", "1", "18", "18", "", "", "83.6", "71.9", "", "52.5", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.3", "84.9", "", "", "", "", "84.4"]} -{"pcdb_id": 9287, "brand_name": "Sile SpA", "model_name": "Turbinox 30", "model_qualifier": "", "winter_efficiency_pct": 80.1, "summer_efficiency_pct": 71.0, "comparative_hot_water_efficiency_pct": 31.2, "output_kw_max": 32.0, "final_year_of_manufacture": null, "raw": ["009287", "000221", "0", "2024/Jan/31 10:17", "Sile SpA", "Sile SpA", "Turbinox 30", "", "", "1985", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "32.00", "32.00", "", "", "80.1", "71.0", "", "31.2", "", "2", "", "", "106", "1", "2", "179", "0", "2", "", "0", "65", "0", "10", "", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "0", "", "0004", "", "", "", "", "", "", "", "", "82.8", "79.3", "", "", "", "", "80.0"]} -{"pcdb_id": 9288, "brand_name": "Sile SpA", "model_name": "SuperRapida 22", "model_qualifier": "", "winter_efficiency_pct": 80.6, "summer_efficiency_pct": 70.5, "comparative_hot_water_efficiency_pct": 49.6, "output_kw_max": 24.0, "final_year_of_manufacture": null, "raw": ["009288", "000221", "0", "2006/Jan/17 12:31", "Sile SpA", "Sile SpA", "SuperRapida 22", "", "", "", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "24", "24", "", "", "80.6", "70.5", "", "49.6", "", "2", "", "", "104", "1", "2", "0", "132", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "", "", "0004", "", "", "", "", "", "", "", "", "82.9", "80.6", "", "", "", "", "81.1"]} -{"pcdb_id": 9289, "brand_name": "Sile SpA", "model_name": "SuperRapida 26", "model_qualifier": "", "winter_efficiency_pct": 80.7, "summer_efficiency_pct": 70.6, "comparative_hot_water_efficiency_pct": 49.7, "output_kw_max": 28.0, "final_year_of_manufacture": null, "raw": ["009289", "000221", "0", "2006/Jan/17 12:31", "Sile SpA", "Sile SpA", "SuperRapida 26", "", "", "", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "28", "28", "", "", "80.7", "70.6", "", "49.7", "", "2", "", "", "104", "1", "2", "0", "132", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "", "", "0004", "", "", "", "", "", "", "", "", "83.3", "81.0", "", "", "", "", "81.4"]} -{"pcdb_id": 9290, "brand_name": "Sile SpA", "model_name": "SuperRapida 31", "model_qualifier": "", "winter_efficiency_pct": 80.5, "summer_efficiency_pct": 70.4, "comparative_hot_water_efficiency_pct": 49.5, "output_kw_max": 34.0, "final_year_of_manufacture": null, "raw": ["009290", "000221", "0", "2006/Jan/17 12:31", "Sile SpA", "Sile SpA", "SuperRapida 31", "", "", "", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "34", "34", "", "", "80.5", "70.4", "", "49.5", "", "2", "", "", "104", "1", "2", "174", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "", "", "0004", "", "", "", "", "", "", "", "", "83.9", "80.5", "", "", "", "", "81.2"]} -{"pcdb_id": 9291, "brand_name": "Sile SpA", "model_name": "Turbinox 30", "model_qualifier": "", "winter_efficiency_pct": 81.9, "summer_efficiency_pct": 72.8, "comparative_hot_water_efficiency_pct": 32.0, "output_kw_max": 32.0, "final_year_of_manufacture": null, "raw": ["009291", "000221", "0", "2024/Jan/31 10:17", "Sile SpA", "Sile SpA", "Turbinox 30", "", "", "1985", "current", "2", "2", "1", "2", "0", "", "", "1", "2", "2", "32.0", "32.0", "", "", "81.9", "72.8", "", "32.0", "", "2", "1", "", "106", "1", "2", "179", "0", "2", "", "0", "65", "0", "10", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "84.6", "81.0", "", "", "", "", "81.7"]} -{"pcdb_id": 9293, "brand_name": "Sile SpA", "model_name": "SuperRapida 26", "model_qualifier": "", "winter_efficiency_pct": 82.6, "summer_efficiency_pct": 72.5, "comparative_hot_water_efficiency_pct": 51.0, "output_kw_max": 28.0, "final_year_of_manufacture": null, "raw": ["009293", "000221", "0", "2006/Jan/17 12:31", "Sile SpA", "Sile SpA", "SuperRapida 26", "", "", "", "current", "2", "2", "1", "2", "0", "", "", "1", "2", "2", "28", "28", "", "", "82.6", "72.5", "", "51.0", "", "2", "1", "", "104", "1", "2", "132", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "", "", "0004", "", "", "", "", "", "", "", "", "85.1", "82.8", "", "", "", "", "83.2"]} -{"pcdb_id": 9294, "brand_name": "Sile SpA", "model_name": "SuperRapida 31", "model_qualifier": "", "winter_efficiency_pct": 82.3, "summer_efficiency_pct": 72.2, "comparative_hot_water_efficiency_pct": 50.8, "output_kw_max": 34.0, "final_year_of_manufacture": null, "raw": ["009294", "000221", "0", "2006/Jan/17 12:31", "Sile SpA", "Sile SpA", "SuperRapida 31", "", "", "", "current", "2", "2", "1", "2", "0", "", "", "1", "2", "2", "34", "34", "", "", "82.3", "72.2", "", "50.8", "", "2", "1", "", "104", "1", "2", "174", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "", "", "0004", "", "", "", "", "", "", "", "", "85.7", "82.3", "", "", "", "", "83.0"]} -{"pcdb_id": 9295, "brand_name": "Ideal", "model_name": "Imax", "model_qualifier": "W60", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 60.0, "final_year_of_manufacture": null, "raw": ["009295", "000008", "0", "2012/Mar/27 10:12", "Ideal Boilers", "Ideal", "Imax", "W60", "PI No 0063BN3218", "2002", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "60", "60", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "84", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.4", "97.7", "", "", "", "", "95.9"]} -{"pcdb_id": 9297, "brand_name": "Ideal", "model_name": "Imax", "model_qualifier": "W45P", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 45.0, "final_year_of_manufacture": null, "raw": ["009297", "000008", "0", "2012/Mar/27 10:12", "Ideal Boilers", "Ideal", "Imax", "W45P", "PI No 0063BN3218", "2002", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "45", "45", "", "", "89.1", "80.1", "", "58.5", "", "2", "1", "", "102", "1", "2", "51", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.3", "99.4", "", "", "", "", "97.5"]} -{"pcdb_id": 9298, "brand_name": "Ideal", "model_name": "Imax", "model_qualifier": "W60P", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 80.4, "comparative_hot_water_efficiency_pct": 58.7, "output_kw_max": 60.0, "final_year_of_manufacture": null, "raw": ["009298", "000008", "0", "2012/Mar/27 10:12", "Ideal Boilers", "Ideal", "Imax", "W60P", "PI No 0063BN3218", "2002", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "60", "60", "", "", "89.4", "80.4", "", "58.7", "", "2", "1", "", "102", "1", "2", "84", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.4", "99.8", "", "", "", "", "98.0"]} -{"pcdb_id": 9300, "brand_name": "Ideal", "model_name": "Imax", "model_qualifier": "W45", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 45.0, "final_year_of_manufacture": null, "raw": ["009300", "000008", "0", "2012/Mar/27 10:12", "Ideal Boilers", "Ideal", "Imax", "W45", "PI No 0063BN3218", "2002", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "45", "45", "", "", "88.2", "79.2", "", "57.9", "", "2", "", "", "102", "1", "2", "51", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.5", "97.2", "", "", "", "", "95.6"]} -{"pcdb_id": 9301, "brand_name": "Turkington Engineering", "model_name": "Eurocal Boiler House", "model_qualifier": "115/140/2", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 41.03, "final_year_of_manufacture": null, "raw": ["009301", "000218", "0", "2012/Mar/27 10:12", "Turkington Engineering", "Turkington Engineering", "Eurocal Boiler House", "115/140/2", "", "1996", "current", "4", "1", "2", "1", "0", "", "", "1", "0", "1", "33.7", "41.03", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.6", "87.7", "", "", "", "", "87.7"]} -{"pcdb_id": 9303, "brand_name": "Turkington Engineering", "model_name": "Eurocal White Cased Kitchen", "model_qualifier": "115/140", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 41.03, "final_year_of_manufacture": null, "raw": ["009303", "000218", "0", "2012/Mar/27 10:12", "Turkington Engineering", "Turkington Engineering", "Eurocal White Cased Kitchen", "115/140", "", "1996", "current", "4", "1", "2", "1", "0", "", "", "1", "0", "1", "33.7", "41.03", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.6", "87.7", "", "", "", "", "87.7"]} -{"pcdb_id": 9305, "brand_name": "Turkington Engineering", "model_name": "Turco 2000 White Cased", "model_qualifier": "115/140", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 41.03, "final_year_of_manufacture": null, "raw": ["009305", "000218", "0", "2012/Mar/27 10:12", "Turkington Engineering", "Turkington Engineering", "Turco 2000 White Cased", "115/140", "", "1996", "current", "4", "1", "2", "1", "0", "", "", "1", "0", "1", "33.7", "41.03", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.6", "87.7", "", "", "", "", "87.7"]} -{"pcdb_id": 9307, "brand_name": "Turkington Engineering", "model_name": "Turco 2000 Boiler House", "model_qualifier": "115/140", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 41.03, "final_year_of_manufacture": null, "raw": ["009307", "000218", "0", "2012/Mar/27 10:12", "Turkington Engineering", "Turkington Engineering", "Turco 2000 Boiler House", "115/140", "", "1996", "current", "4", "1", "2", "1", "0", "", "", "1", "0", "1", "33.7", "41.03", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.6", "87.7", "", "", "", "", "87.7"]} -{"pcdb_id": 9309, "brand_name": "Turkington Engineering", "model_name": "Eurocal Boiler House", "model_qualifier": "140/170/2", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 52.75, "final_year_of_manufacture": null, "raw": ["009309", "000218", "0", "2012/Mar/27 10:12", "Turkington Engineering", "Turkington Engineering", "Eurocal Boiler House", "140/170/2", "", "1996", "current", "4", "1", "2", "1", "0", "", "", "1", "0", "1", "41.03", "52.75", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.9", "87.7", "", "", "", "", "87.5"]} -{"pcdb_id": 9311, "brand_name": "Turkington Engineering", "model_name": "Eurocal White Cased Kitchen", "model_qualifier": "140/170", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 52.75, "final_year_of_manufacture": null, "raw": ["009311", "000218", "0", "2012/Mar/27 10:12", "Turkington Engineering", "Turkington Engineering", "Eurocal White Cased Kitchen", "140/170", "", "1996", "current", "4", "1", "2", "1", "0", "", "", "1", "0", "1", "41.03", "52.75", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.9", "87.7", "", "", "", "", "87.5"]} -{"pcdb_id": 9313, "brand_name": "Turkington Engineering", "model_name": "Turco 2000 White Cased", "model_qualifier": "140/170", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 52.75, "final_year_of_manufacture": null, "raw": ["009313", "000218", "0", "2012/Mar/27 10:12", "Turkington Engineering", "Turkington Engineering", "Turco 2000 White Cased", "140/170", "", "1996", "current", "4", "1", "2", "1", "0", "", "", "1", "0", "1", "41.03", "52.75", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.9", "87.7", "", "", "", "", "87.5"]} -{"pcdb_id": 9316, "brand_name": "Turkington Engineering", "model_name": "Turco 2000 Boiler House", "model_qualifier": "140/170", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 52.75, "final_year_of_manufacture": null, "raw": ["009316", "000218", "0", "2012/Mar/27 10:12", "Turkington Engineering", "Turkington Engineering", "Turco 2000 Boiler House", "140/170", "", "1996", "current", "4", "1", "2", "1", "0", "", "", "1", "0", "1", "41.03", "52.75", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.9", "87.7", "", "", "", "", "87.5"]} -{"pcdb_id": 9318, "brand_name": "Turkington Engineering", "model_name": "Turco 2000 Outdoor System", "model_qualifier": "90/115", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 33.7, "final_year_of_manufacture": null, "raw": ["009318", "000218", "0", "2012/Mar/27 10:12", "Turkington Engineering", "Turkington Engineering", "Turco 2000 Outdoor System", "90/115", "", "1996", "current", "4", "1", "2", "1", "0", "", "", "1", "0", "1", "26.37", "33.7", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.2", "87.7", "", "", "", "", "87.6"]} -{"pcdb_id": 9320, "brand_name": "Turkington Engineering", "model_name": "Turco 2000 White System", "model_qualifier": "90/115", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 33.7, "final_year_of_manufacture": null, "raw": ["009320", "000218", "0", "2012/Mar/27 10:12", "Turkington Engineering", "Turkington Engineering", "Turco 2000 White System", "90/115", "", "1996", "current", "4", "1", "2", "1", "0", "", "", "1", "0", "1", "26.37", "33.7", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.2", "87.7", "", "", "", "", "87.6"]} -{"pcdb_id": 9322, "brand_name": "Turkington Engineering", "model_name": "Turco 2000 Outdoor", "model_qualifier": "90/115", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 33.7, "final_year_of_manufacture": null, "raw": ["009322", "000218", "0", "2012/Mar/27 10:12", "Turkington Engineering", "Turkington Engineering", "Turco 2000 Outdoor", "90/115", "", "1996", "current", "4", "1", "2", "1", "0", "", "", "1", "0", "1", "26.37", "33.7", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.2", "87.7", "", "", "", "", "87.6"]} -{"pcdb_id": 9324, "brand_name": "Turkington Engineering", "model_name": "Turco 2000 Boiler House", "model_qualifier": "90/115", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 33.7, "final_year_of_manufacture": null, "raw": ["009324", "000218", "0", "2012/Mar/27 10:12", "Turkington Engineering", "Turkington Engineering", "Turco 2000 Boiler House", "90/115", "", "1996", "current", "4", "1", "2", "1", "0", "", "", "1", "0", "1", "26.37", "33.7", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.2", "87.7", "", "", "", "", "87.6"]} -{"pcdb_id": 9326, "brand_name": "Turkington Engineering", "model_name": "Turco 2000 White Cased", "model_qualifier": "90/115", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 33.7, "final_year_of_manufacture": null, "raw": ["009326", "000218", "0", "2012/Mar/27 10:12", "Turkington Engineering", "Turkington Engineering", "Turco 2000 White Cased", "90/115", "", "1996", "current", "4", "1", "2", "1", "0", "", "", "1", "0", "1", "26.37", "33.7", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.2", "87.7", "", "", "", "", "87.6"]} -{"pcdb_id": 9328, "brand_name": "Turkington Engineering", "model_name": "Eurocal Outdoor System", "model_qualifier": "90/115", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 33.7, "final_year_of_manufacture": null, "raw": ["009328", "000218", "0", "2012/Mar/27 10:12", "Turkington Engineering", "Turkington Engineering", "Eurocal Outdoor System", "90/115", "", "1996", "current", "4", "1", "2", "1", "0", "", "", "1", "0", "1", "26.37", "33.7", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.2", "87.7", "", "", "", "", "87.6"]} -{"pcdb_id": 9330, "brand_name": "Turkington Engineering", "model_name": "Eurocal White Cased System", "model_qualifier": "90/115", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 33.7, "final_year_of_manufacture": null, "raw": ["009330", "000218", "0", "2012/Mar/27 10:12", "Turkington Engineering", "Turkington Engineering", "Eurocal White Cased System", "90/115", "", "1996", "current", "4", "1", "2", "1", "0", "", "", "1", "0", "1", "26.37", "33.7", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.2", "87.7", "", "", "", "", "87.6"]} -{"pcdb_id": 9332, "brand_name": "Turkington Engineering", "model_name": "Eurocal Outdoor", "model_qualifier": "90/115", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 33.7, "final_year_of_manufacture": null, "raw": ["009332", "000218", "0", "2012/Mar/27 10:12", "Turkington Engineering", "Turkington Engineering", "Eurocal Outdoor", "90/115", "", "1996", "current", "4", "1", "2", "1", "0", "", "", "1", "0", "1", "26.37", "33.7", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.2", "87.7", "", "", "", "", "87.6"]} -{"pcdb_id": 9334, "brand_name": "Turkington Engineering", "model_name": "Eurocal White Cased Kitchen", "model_qualifier": "90/115", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 33.7, "final_year_of_manufacture": null, "raw": ["009334", "000218", "0", "2012/Mar/27 10:12", "Turkington Engineering", "Turkington Engineering", "Eurocal White Cased Kitchen", "90/115", "", "1996", "current", "4", "1", "2", "1", "0", "", "", "1", "0", "1", "26.37", "33.7", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.2", "87.7", "", "", "", "", "87.6"]} -{"pcdb_id": 9336, "brand_name": "Turkington Engineering", "model_name": "Eurocal Boiler House", "model_qualifier": "90/115/2", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 33.7, "final_year_of_manufacture": null, "raw": ["009336", "000218", "0", "2012/Mar/27 10:12", "Turkington Engineering", "Turkington Engineering", "Eurocal Boiler House", "90/115/2", "", "1996", "current", "4", "1", "2", "1", "0", "", "", "1", "0", "1", "26.37", "33.7", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.2", "87.7", "", "", "", "", "87.6"]} -{"pcdb_id": 9338, "brand_name": "Turkington Engineering", "model_name": "Turco 2000 Outdoor Combi", "model_qualifier": "90/115", "winter_efficiency_pct": 84.9, "summer_efficiency_pct": 75.4, "comparative_hot_water_efficiency_pct": 53.0, "output_kw_max": 33.7, "final_year_of_manufacture": null, "raw": ["009338", "000218", "0", "2003/Jan/13 11:46", "Turkington Engineering", "Turkington Engineering", "Turco 2000 Outdoor Combi", "90/115", "", "1996", "current", "4", "1", "2", "2", "0", "", "", "1", "0", "1", "26.37", "33.7", "", "", "84.9", "75.4", "", "53.0", "", "2", "", "", "202", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.2", "87.7", "", "", "", "", "87.6"]} -{"pcdb_id": 9340, "brand_name": "Turkington Engineering", "model_name": "Turco 2000 White Combi", "model_qualifier": "90/115", "winter_efficiency_pct": 84.9, "summer_efficiency_pct": 75.4, "comparative_hot_water_efficiency_pct": 53.0, "output_kw_max": 33.7, "final_year_of_manufacture": null, "raw": ["009340", "000218", "0", "2003/Jan/13 11:47", "Turkington Engineering", "Turkington Engineering", "Turco 2000 White Combi", "90/115", "", "1996", "current", "4", "1", "2", "2", "0", "", "", "1", "0", "1", "26.37", "33.7", "", "", "84.9", "75.4", "", "53.0", "", "2", "", "", "202", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.2", "87.7", "", "", "", "", "87.6"]} -{"pcdb_id": 9342, "brand_name": "Turkington Engineering", "model_name": "Eurocal White Cased Combi", "model_qualifier": "90/115", "winter_efficiency_pct": 84.9, "summer_efficiency_pct": 75.4, "comparative_hot_water_efficiency_pct": 53.0, "output_kw_max": 33.7, "final_year_of_manufacture": null, "raw": ["009342", "000218", "0", "2003/Jan/13 11:47", "Turkington Engineering", "Turkington Engineering", "Eurocal White Cased Combi", "90/115", "", "1996", "current", "4", "1", "2", "2", "0", "", "", "1", "0", "1", "26.37", "33.7", "", "", "84.9", "75.4", "", "53.0", "", "2", "", "", "202", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.2", "87.7", "", "", "", "", "87.6"]} -{"pcdb_id": 9344, "brand_name": "Turkington Engineering", "model_name": "Eurocal Outdoor Combi", "model_qualifier": "90/115", "winter_efficiency_pct": 84.9, "summer_efficiency_pct": 75.4, "comparative_hot_water_efficiency_pct": 53.0, "output_kw_max": 33.7, "final_year_of_manufacture": null, "raw": ["009344", "000218", "0", "2003/Jan/13 11:48", "Turkington Engineering", "Turkington Engineering", "Eurocal Outdoor Combi", "90/115", "", "1996", "current", "4", "1", "2", "2", "0", "", "", "1", "0", "1", "26.37", "33.7", "", "", "84.9", "75.4", "", "53.0", "", "2", "", "", "202", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.2", "87.7", "", "", "", "", "87.6"]} -{"pcdb_id": 9347, "brand_name": "Turkington Engineering", "model_name": "Eurocal Boiler House", "model_qualifier": "70/90", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 26.37, "final_year_of_manufacture": null, "raw": ["009347", "000218", "0", "2012/Mar/27 10:12", "Turkington Engineering", "Turkington Engineering", "Eurocal Boiler House", "70/90", "", "1996", "current", "4", "1", "2", "1", "0", "", "", "1", "0", "1", "20.5", "26.37", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.2", "87.7", "", "", "", "", "87.6"]} -{"pcdb_id": 9349, "brand_name": "Turkington Engineering", "model_name": "Eurocal White Cased Kitchen", "model_qualifier": "70/90", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 26.37, "final_year_of_manufacture": null, "raw": ["009349", "000218", "0", "2012/Mar/27 10:12", "Turkington Engineering", "Turkington Engineering", "Eurocal White Cased Kitchen", "70/90", "", "1996", "current", "4", "1", "2", "1", "0", "", "", "1", "0", "1", "20.5", "26.37", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.2", "87.7", "", "", "", "", "87.6"]} -{"pcdb_id": 9351, "brand_name": "Turkington Engineering", "model_name": "Eurocal Outdoor", "model_qualifier": "70/90", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 26.37, "final_year_of_manufacture": null, "raw": ["009351", "000218", "0", "2012/Mar/27 10:12", "Turkington Engineering", "Turkington Engineering", "Eurocal Outdoor", "70/90", "", "1996", "current", "4", "1", "2", "1", "0", "", "", "1", "0", "1", "20.5", "26.37", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.2", "87.7", "", "", "", "", "87.6"]} -{"pcdb_id": 9353, "brand_name": "Turkington Engineering", "model_name": "Eurocal White Cased System", "model_qualifier": "70/90", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 26.37, "final_year_of_manufacture": null, "raw": ["009353", "000218", "0", "2012/Mar/27 10:12", "Turkington Engineering", "Turkington Engineering", "Eurocal White Cased System", "70/90", "", "1996", "current", "4", "1", "2", "1", "0", "", "", "1", "0", "1", "20.5", "26.37", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.2", "87.7", "", "", "", "", "87.6"]} -{"pcdb_id": 9355, "brand_name": "Turkington Engineering", "model_name": "Eurocal Outdoor System", "model_qualifier": "70/90", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 26.37, "final_year_of_manufacture": null, "raw": ["009355", "000218", "0", "2012/Mar/27 10:12", "Turkington Engineering", "Turkington Engineering", "Eurocal Outdoor System", "70/90", "", "1996", "current", "4", "1", "2", "1", "0", "", "", "1", "0", "1", "20.5", "26.37", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.2", "87.7", "", "", "", "", "87.6"]} -{"pcdb_id": 9357, "brand_name": "Turkington Engineering", "model_name": "Turco 2000 White Cased", "model_qualifier": "70/90", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 26.37, "final_year_of_manufacture": null, "raw": ["009357", "000218", "0", "2012/Mar/27 10:12", "Turkington Engineering", "Turkington Engineering", "Turco 2000 White Cased", "70/90", "", "1996", "current", "4", "1", "2", "1", "0", "", "", "1", "0", "1", "20.5", "26.37", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.2", "87.7", "", "", "", "", "87.6"]} -{"pcdb_id": 9359, "brand_name": "Turkington Engineering", "model_name": "Turco 2000 Boiler House", "model_qualifier": "70/90", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 26.37, "final_year_of_manufacture": null, "raw": ["009359", "000218", "0", "2012/Mar/27 10:12", "Turkington Engineering", "Turkington Engineering", "Turco 2000 Boiler House", "70/90", "", "1996", "current", "4", "1", "2", "1", "0", "", "", "1", "0", "1", "20.5", "26.37", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.2", "87.7", "", "", "", "", "87.6"]} -{"pcdb_id": 9361, "brand_name": "Turkington Engineering", "model_name": "Turco 2000 Outdoor", "model_qualifier": "70/90", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 26.37, "final_year_of_manufacture": null, "raw": ["009361", "000218", "0", "2012/Mar/27 10:12", "Turkington Engineering", "Turkington Engineering", "Turco 2000 Outdoor", "70/90", "", "1996", "current", "4", "1", "2", "1", "0", "", "", "1", "0", "1", "20.5", "26.37", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.2", "87.7", "", "", "", "", "87.6"]} -{"pcdb_id": 9363, "brand_name": "Turkington Engineering", "model_name": "Turco 2000 White Cased System", "model_qualifier": "70/90", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 26.37, "final_year_of_manufacture": null, "raw": ["009363", "000218", "0", "2012/Mar/27 10:12", "Turkington Engineering", "Turkington Engineering", "Turco 2000 White Cased System", "70/90", "", "1996", "current", "4", "1", "2", "1", "0", "", "", "1", "0", "1", "20.5", "26.37", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.2", "87.7", "", "", "", "", "87.6"]} -{"pcdb_id": 9365, "brand_name": "Turkington Engineering", "model_name": "Turco 2000 Outdoor System", "model_qualifier": "70/90", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 26.37, "final_year_of_manufacture": null, "raw": ["009365", "000218", "0", "2012/Mar/27 10:12", "Turkington Engineering", "Turkington Engineering", "Turco 2000 Outdoor System", "70/90", "", "1996", "current", "4", "1", "2", "1", "0", "", "", "1", "0", "1", "20.5", "26.37", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.2", "87.7", "", "", "", "", "87.6"]} -{"pcdb_id": 9369, "brand_name": "Turkington Engineering", "model_name": "Eurocal Outdoor Combi", "model_qualifier": "70/90", "winter_efficiency_pct": 84.9, "summer_efficiency_pct": 75.4, "comparative_hot_water_efficiency_pct": 53.0, "output_kw_max": 26.37, "final_year_of_manufacture": null, "raw": ["009369", "000218", "0", "2003/Jan/13 12:03", "Turkington Engineering", "Turkington Engineering", "Eurocal Outdoor Combi", "70/90", "", "1996", "current", "4", "1", "2", "2", "0", "", "", "1", "0", "1", "20.5", "26.37", "", "", "84.9", "75.4", "", "53.0", "", "2", "", "", "202", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.2", "87.7", "", "", "", "", "87.6"]} -{"pcdb_id": 9371, "brand_name": "Turkington Engineering", "model_name": "Eurocal white Cased Combi", "model_qualifier": "70/90", "winter_efficiency_pct": 84.9, "summer_efficiency_pct": 75.4, "comparative_hot_water_efficiency_pct": 53.0, "output_kw_max": 26.37, "final_year_of_manufacture": null, "raw": ["009371", "000218", "0", "2003/Jan/13 12:04", "Turkington Engineering", "Turkington Engineering", "Eurocal white Cased Combi", "70/90", "", "1996", "current", "4", "1", "2", "2", "0", "", "", "1", "0", "1", "20.5", "26.37", "", "", "84.9", "75.4", "", "53.0", "", "2", "", "", "202", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.2", "87.7", "", "", "", "", "87.6"]} -{"pcdb_id": 9373, "brand_name": "Turkington Engineering", "model_name": "Turco 2000 White Cased Combi", "model_qualifier": "70/90", "winter_efficiency_pct": 84.9, "summer_efficiency_pct": 75.4, "comparative_hot_water_efficiency_pct": 53.0, "output_kw_max": 26.37, "final_year_of_manufacture": null, "raw": ["009373", "000218", "0", "2003/Jan/13 12:04", "Turkington Engineering", "Turkington Engineering", "Turco 2000 White Cased Combi", "70/90", "", "1996", "current", "4", "1", "2", "2", "0", "", "", "1", "0", "1", "20.5", "26.37", "", "", "84.9", "75.4", "", "53.0", "", "2", "", "", "202", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.2", "87.7", "", "", "", "", "87.6"]} -{"pcdb_id": 9375, "brand_name": "Turkington Engineering", "model_name": "Turco 2000 Outdoor Combi", "model_qualifier": "70/90", "winter_efficiency_pct": 84.9, "summer_efficiency_pct": 75.4, "comparative_hot_water_efficiency_pct": 53.0, "output_kw_max": 26.37, "final_year_of_manufacture": null, "raw": ["009375", "000218", "0", "2003/Jan/13 12:05", "Turkington Engineering", "Turkington Engineering", "Turco 2000 Outdoor Combi", "70/90", "", "1996", "current", "4", "1", "2", "2", "0", "", "", "1", "0", "1", "20.5", "26.37", "", "", "84.9", "75.4", "", "53.0", "", "2", "", "", "202", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.2", "87.7", "", "", "", "", "87.6"]} -{"pcdb_id": 9377, "brand_name": "Turkington Engineering", "model_name": "Eurocal Boiler House", "model_qualifier": "50/70/2", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 20.5, "final_year_of_manufacture": null, "raw": ["009377", "000218", "0", "2012/Mar/27 10:12", "Turkington Engineering", "Turkington Engineering", "Eurocal Boiler House", "50/70/2", "", "1996", "current", "4", "1", "2", "1", "0", "", "", "1", "0", "1", "14.65", "20.5", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.2", "87.7", "", "", "", "", "87.6"]} -{"pcdb_id": 9379, "brand_name": "Turkington Engineering", "model_name": "Eurocal White Cased Kitchen", "model_qualifier": "50/70", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 20.5, "final_year_of_manufacture": null, "raw": ["009379", "000218", "0", "2012/Mar/27 10:12", "Turkington Engineering", "Turkington Engineering", "Eurocal White Cased Kitchen", "50/70", "", "1996", "current", "4", "1", "2", "1", "0", "", "", "1", "0", "1", "14.65", "20.5", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.2", "87.7", "", "", "", "", "87.6"]} -{"pcdb_id": 9381, "brand_name": "Turkington Engineering", "model_name": "Eurocal Outdoor", "model_qualifier": "50/70", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 20.5, "final_year_of_manufacture": null, "raw": ["009381", "000218", "0", "2012/Mar/27 10:12", "Turkington Engineering", "Turkington Engineering", "Eurocal Outdoor", "50/70", "", "1996", "current", "4", "1", "2", "1", "0", "", "", "1", "0", "1", "14.65", "20.5", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.2", "87.7", "", "", "", "", "87.6"]} -{"pcdb_id": 9383, "brand_name": "Turkington Engineering", "model_name": "Eurocal White Cased System", "model_qualifier": "50/70", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 20.5, "final_year_of_manufacture": null, "raw": ["009383", "000218", "0", "2012/Mar/27 10:12", "Turkington Engineering", "Turkington Engineering", "Eurocal White Cased System", "50/70", "", "1996", "current", "4", "1", "2", "1", "0", "", "", "1", "0", "1", "14.65", "20.50", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.2", "87.7", "", "", "", "", "87.6"]} -{"pcdb_id": 9385, "brand_name": "Turkington Engineering", "model_name": "Eurocal Outdoor System", "model_qualifier": "50/70", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 20.5, "final_year_of_manufacture": null, "raw": ["009385", "000218", "0", "2012/Mar/27 10:12", "Turkington Engineering", "Turkington Engineering", "Eurocal Outdoor System", "50/70", "", "1996", "current", "4", "1", "2", "1", "0", "", "", "1", "0", "1", "14.65", "20.50", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.2", "87.7", "", "", "", "", "87.6"]} -{"pcdb_id": 9387, "brand_name": "Turkington Engineering", "model_name": "Turco 2000 White Cased", "model_qualifier": "50/70", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 20.5, "final_year_of_manufacture": null, "raw": ["009387", "000218", "0", "2012/Mar/27 10:12", "Turkington Engineering", "Turkington Engineering", "Turco 2000 White Cased", "50/70", "", "1996", "current", "4", "1", "2", "1", "0", "", "", "1", "0", "1", "14.65", "20.50", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.2", "87.7", "", "", "", "", "87.6"]} -{"pcdb_id": 9389, "brand_name": "Turkington Engineering", "model_name": "Turco 2000 Boiler House", "model_qualifier": "50/70", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 20.5, "final_year_of_manufacture": null, "raw": ["009389", "000218", "0", "2012/Mar/27 10:12", "Turkington Engineering", "Turkington Engineering", "Turco 2000 Boiler House", "50/70", "", "1996", "current", "4", "1", "2", "1", "0", "", "", "1", "0", "1", "14.65", "20.50", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.2", "87.7", "", "", "", "", "87.6"]} -{"pcdb_id": 9391, "brand_name": "Turkington Engineering", "model_name": "Turco 2000 Outdoor", "model_qualifier": "50/70", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 20.5, "final_year_of_manufacture": null, "raw": ["009391", "000218", "0", "2012/Mar/27 10:12", "Turkington Engineering", "Turkington Engineering", "Turco 2000 Outdoor", "50/70", "", "1996", "current", "4", "1", "2", "1", "0", "", "", "1", "0", "1", "14.65", "20.50", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.2", "87.7", "", "", "", "", "87.6"]} -{"pcdb_id": 9393, "brand_name": "Turkington Engineering", "model_name": "Turco 2000 White System", "model_qualifier": "50/70", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 20.5, "final_year_of_manufacture": null, "raw": ["009393", "000218", "0", "2012/Mar/27 10:12", "Turkington Engineering", "Turkington Engineering", "Turco 2000 White System", "50/70", "", "1996", "current", "4", "1", "2", "1", "0", "", "", "1", "0", "1", "14.65", "20.50", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.2", "87.7", "", "", "", "", "87.6"]} -{"pcdb_id": 9395, "brand_name": "Turkington Engineering", "model_name": "Turco 2000 Outdoor System", "model_qualifier": "50/70", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 20.5, "final_year_of_manufacture": null, "raw": ["009395", "000218", "0", "2012/Mar/27 10:12", "Turkington Engineering", "Turkington Engineering", "Turco 2000 Outdoor System", "50/70", "", "1996", "current", "4", "1", "2", "1", "0", "", "", "1", "0", "1", "14.65", "20.50", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.2", "87.7", "", "", "", "", "87.6"]} -{"pcdb_id": 9397, "brand_name": "Turkington Engineering", "model_name": "Eurocal White Cased Combi", "model_qualifier": "50/70", "winter_efficiency_pct": 84.9, "summer_efficiency_pct": 75.4, "comparative_hot_water_efficiency_pct": 53.0, "output_kw_max": 20.5, "final_year_of_manufacture": null, "raw": ["009397", "000218", "0", "2003/Jan/13 12:13", "Turkington Engineering", "Turkington Engineering", "Eurocal White Cased Combi", "50/70", "", "1996", "current", "4", "1", "2", "2", "0", "", "", "1", "0", "1", "14.65", "20.50", "", "", "84.9", "75.4", "", "53.0", "", "2", "", "", "202", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.2", "87.7", "", "", "", "", "87.6"]} -{"pcdb_id": 9399, "brand_name": "Turkington Engineering", "model_name": "Eurocal Outdoor Combi", "model_qualifier": "50/70", "winter_efficiency_pct": 84.9, "summer_efficiency_pct": 75.4, "comparative_hot_water_efficiency_pct": 53.0, "output_kw_max": 20.5, "final_year_of_manufacture": null, "raw": ["009399", "000218", "0", "2003/Jan/13 12:13", "Turkington Engineering", "Turkington Engineering", "Eurocal Outdoor Combi", "50/70", "", "1996", "current", "4", "1", "2", "2", "0", "", "", "1", "0", "1", "14.65", "20.50", "", "", "84.9", "75.4", "", "53.0", "", "2", "", "", "202", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.2", "87.7", "", "", "", "", "87.6"]} -{"pcdb_id": 9403, "brand_name": "Turkington Engineering", "model_name": "Turco 2000 White Combi", "model_qualifier": "50/70", "winter_efficiency_pct": 84.9, "summer_efficiency_pct": 75.4, "comparative_hot_water_efficiency_pct": 53.0, "output_kw_max": 20.5, "final_year_of_manufacture": null, "raw": ["009403", "000218", "0", "2003/Jan/13 12:14", "Turkington Engineering", "Turkington Engineering", "Turco 2000 White Combi", "50/70", "", "1996", "current", "4", "1", "2", "2", "0", "", "", "1", "0", "1", "14.65", "20.50", "", "", "84.9", "75.4", "", "53.0", "", "2", "", "", "202", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.2", "87.7", "", "", "", "", "87.6"]} -{"pcdb_id": 9405, "brand_name": "Turkington Engineering", "model_name": "Turco 2000 Outdoor Combi", "model_qualifier": "50/70", "winter_efficiency_pct": 84.9, "summer_efficiency_pct": 75.4, "comparative_hot_water_efficiency_pct": 53.0, "output_kw_max": 20.5, "final_year_of_manufacture": null, "raw": ["009405", "000218", "0", "2003/Jan/13 12:14", "Turkington Engineering", "Turkington Engineering", "Turco 2000 Outdoor Combi", "50/70", "", "1996", "current", "4", "1", "2", "2", "0", "", "", "1", "0", "1", "14.65", "20.50", "", "", "84.9", "75.4", "", "53.0", "", "2", "", "", "202", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.2", "87.7", "", "", "", "", "87.6"]} -{"pcdb_id": 9407, "brand_name": "Ravenheat", "model_name": "CSI System A T", "model_qualifier": "", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 80.4, "comparative_hot_water_efficiency_pct": 58.7, "output_kw_max": 22.3, "final_year_of_manufacture": null, "raw": ["009407", "000026", "0", "2012/Mar/27 10:12", "Ravenheat", "Ravenheat", "CSI System A T", "", "", "2002", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "22.3", "22.3", "", "", "89.4", "80.4", "", "58.7", "", "2", "", "", "102", "1", "2", "160", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.9", "100.0", "", "", "", "", "97.9"]} -{"pcdb_id": 9408, "brand_name": "Ravenheat", "model_name": "CSI System A", "model_qualifier": "", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 80.4, "comparative_hot_water_efficiency_pct": 58.7, "output_kw_max": 22.3, "final_year_of_manufacture": null, "raw": ["009408", "000026", "0", "2012/Mar/27 10:12", "Ravenheat", "Ravenheat", "CSI System A", "", "", "2002", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "22.3", "22.3", "", "", "89.4", "80.4", "", "58.7", "", "2", "", "", "102", "1", "2", "160", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.9", "100.0", "", "", "", "", "97.9"]} -{"pcdb_id": 9409, "brand_name": "Ravenheat", "model_name": "CSI Primary A", "model_qualifier": "", "winter_efficiency_pct": 87.2, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 22.3, "final_year_of_manufacture": null, "raw": ["009409", "000026", "0", "2012/Mar/27 10:12", "Ravenheat", "Ravenheat", "CSI Primary A", "", "", "2002", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "10.6", "22.3", "", "", "87.2", "79.6", "", "58.2", "", "2", "", "", "101", "1", "1", "60", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "88.9", "98.0", "", "", "", "", "96.3"]} -{"pcdb_id": 9410, "brand_name": "Ravenheat", "model_name": "CSI 85 A", "model_qualifier": "", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 56.8, "output_kw_max": 22.3, "final_year_of_manufacture": null, "raw": ["009410", "000026", "0", "2006/Jan/17 12:31", "Ravenheat", "Ravenheat", "CSI 85 A", "", "", "2002", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "22.3", "22.3", "", "", "89.4", "80.8", "", "56.8", "", "2", "", "", "104", "1", "2", "160", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "", "", "0005", "", "", "", "", "", "", "", "", "88.9", "100.0", "", "", "", "", "97.9"]} -{"pcdb_id": 9411, "brand_name": "Ravenheat", "model_name": "CSI 85 A T", "model_qualifier": "", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 56.8, "output_kw_max": 22.3, "final_year_of_manufacture": null, "raw": ["009411", "000026", "0", "2006/Jan/17 12:31", "Ravenheat", "Ravenheat", "CSI 85 A T", "", "", "2002", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "22.3", "22.3", "", "", "89.4", "80.8", "", "56.8", "", "2", "", "", "104", "1", "2", "160", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "", "", "0005", "", "", "", "", "", "", "", "", "88.9", "100.0", "", "", "", "", "97.9"]} -{"pcdb_id": 9412, "brand_name": "Ravenheat", "model_name": "CSI System A", "model_qualifier": "", "winter_efficiency_pct": 90.6, "summer_efficiency_pct": 81.6, "comparative_hot_water_efficiency_pct": 59.6, "output_kw_max": 22.3, "final_year_of_manufacture": null, "raw": ["009412", "000026", "0", "2012/Mar/27 10:12", "Ravenheat", "Ravenheat", "CSI System A", "", "", "2002", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "22.3", "22.3", "", "", "90.6", "81.6", "", "59.6", "", "2", "0", "", "102", "1", "2", "160", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.9", "100.1", "", "", "", "", "98.4"]} -{"pcdb_id": 9413, "brand_name": "Ravenheat", "model_name": "CSI System A T", "model_qualifier": "", "winter_efficiency_pct": 90.6, "summer_efficiency_pct": 81.6, "comparative_hot_water_efficiency_pct": 59.6, "output_kw_max": 22.3, "final_year_of_manufacture": null, "raw": ["009413", "000026", "0", "2012/Mar/27 10:12", "Ravenheat", "Ravenheat", "CSI System A T", "", "", "2002", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "22.3", "22.3", "", "", "90.6", "81.6", "", "59.6", "", "2", "0", "", "102", "1", "2", "160", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.9", "100.1", "", "", "", "", "98.4"]} -{"pcdb_id": 9414, "brand_name": "Ravenheat", "model_name": "CSI Primary A", "model_qualifier": "", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 81.6, "comparative_hot_water_efficiency_pct": 59.6, "output_kw_max": 22.3, "final_year_of_manufacture": null, "raw": ["009414", "000026", "0", "2012/Mar/27 10:12", "Ravenheat", "Ravenheat", "CSI Primary A", "", "", "2002", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "10.6", "22.3", "", "", "89.2", "81.6", "", "59.6", "", "2", "0", "", "101", "1", "1", "60", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.9", "100.1", "", "", "", "", "98.4"]} -{"pcdb_id": 9415, "brand_name": "Ravenheat", "model_name": "CSI 85 A T", "model_qualifier": "", "winter_efficiency_pct": 90.6, "summer_efficiency_pct": 82.0, "comparative_hot_water_efficiency_pct": 57.6, "output_kw_max": 22.3, "final_year_of_manufacture": null, "raw": ["009415", "000026", "0", "2006/Jan/17 12:31", "Ravenheat", "Ravenheat", "CSI 85 A T", "", "", "2002", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "22.3", "22.3", "", "", "90.6", "82.0", "", "57.6", "", "2", "0", "", "104", "1", "2", "160", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "", "", "0005", "", "", "", "", "", "", "", "", "90.9", "100.1", "", "", "", "", "98.4"]} -{"pcdb_id": 9416, "brand_name": "Ravenheat", "model_name": "CSI 85 A", "model_qualifier": "", "winter_efficiency_pct": 90.6, "summer_efficiency_pct": 82.0, "comparative_hot_water_efficiency_pct": 57.6, "output_kw_max": 22.3, "final_year_of_manufacture": null, "raw": ["009416", "000026", "0", "2006/Jan/17 12:31", "Ravenheat", "Ravenheat", "CSI 85 A", "", "", "2002", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "22.3", "22.3", "", "", "90.6", "82.0", "", "57.6", "", "2", "0", "", "104", "1", "2", "160", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "", "", "0005", "", "", "", "", "", "", "", "", "90.9", "100.1", "", "", "", "", "98.4"]} -{"pcdb_id": 9417, "brand_name": "MHS Boilers", "model_name": "Stata Streamline", "model_qualifier": "68", "winter_efficiency_pct": 87.7, "summer_efficiency_pct": 78.7, "comparative_hot_water_efficiency_pct": 57.5, "output_kw_max": 67.8, "final_year_of_manufacture": 2004, "raw": ["009417", "000024", "0", "2012/Mar/27 10:12", "MHS Boilers", "MHS Boilers", "Stata Streamline", "68", "", "2002", "2004", "1", "2", "1", "1", "0", "", "", "2", "3", "1", "67.8", "67.8", "", "", "87.7", "78.7", "", "57.5", "", "2", "", "", "102", "1", "2", "60", "6", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.3", "96.2", "", "", "", "", "94.5"]} -{"pcdb_id": 9419, "brand_name": "Aquaflame", "model_name": "Evolution II 110", "model_qualifier": "", "winter_efficiency_pct": 85.7, "summer_efficiency_pct": 74.0, "comparative_hot_water_efficiency_pct": 54.0, "output_kw_max": 33.1, "final_year_of_manufacture": null, "raw": ["009419", "000039", "0", "2012/Mar/27 10:12", "Aquaflame", "Aquaflame", "Evolution II 110", "", "", "2002", "current", "4", "1", "1", "1", "0", "", "", "1", "3", "1", "33.1", "33.1", "", "", "85.7", "74.0", "", "54.0", "", "2", "", "", "201", "1", "1", "100", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.7", "85.6", "", "", "", "", "85.7"]} -{"pcdb_id": 9422, "brand_name": "Aquaflame", "model_name": "Evolution II 95", "model_qualifier": "", "winter_efficiency_pct": 85.1, "summer_efficiency_pct": 73.4, "comparative_hot_water_efficiency_pct": 53.6, "output_kw_max": 27.1, "final_year_of_manufacture": null, "raw": ["009422", "000039", "0", "2012/Mar/27 10:12", "Aquaflame", "Aquaflame", "Evolution II 95", "", "", "2002", "current", "4", "1", "1", "1", "0", "", "", "1", "3", "1", "27.1", "27.1", "", "", "85.1", "73.4", "", "53.6", "", "2", "", "", "201", "1", "1", "100", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.1", "85.1", "", "", "", "", "85.1"]} -{"pcdb_id": 9424, "brand_name": "Aquaflame", "model_name": "Evolution II 80", "model_qualifier": "", "winter_efficiency_pct": 85.0, "summer_efficiency_pct": 73.3, "comparative_hot_water_efficiency_pct": 53.6, "output_kw_max": 22.1, "final_year_of_manufacture": null, "raw": ["009424", "000039", "0", "2012/Mar/27 10:12", "Aquaflame", "Aquaflame", "Evolution II 80", "", "", "2002", "current", "4", "1", "1", "1", "0", "", "", "1", "3", "1", "22.1", "22.1", "", "", "85.0", "73.3", "", "53.6", "", "2", "", "", "201", "1", "1", "100", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "84.7", "85.4", "", "", "", "", "85.2"]} -{"pcdb_id": 9425, "brand_name": "Aquaflame", "model_name": "Evolution II 65", "model_qualifier": "", "winter_efficiency_pct": 85.0, "summer_efficiency_pct": 73.3, "comparative_hot_water_efficiency_pct": 53.6, "output_kw_max": 18.2, "final_year_of_manufacture": null, "raw": ["009425", "000039", "0", "2012/Mar/27 10:12", "Aquaflame", "Aquaflame", "Evolution II 65", "", "", "2002", "current", "4", "1", "1", "1", "0", "", "", "1", "3", "1", "18.2", "18.2", "", "", "85.0", "73.3", "", "53.6", "", "2", "", "", "201", "1", "1", "100", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "84.8", "85.3", "", "", "", "", "85.2"]} -{"pcdb_id": 9428, "brand_name": "Aquaflame", "model_name": "Evolution II 50", "model_qualifier": "", "winter_efficiency_pct": 85.0, "summer_efficiency_pct": 73.3, "comparative_hot_water_efficiency_pct": 53.6, "output_kw_max": 14.4, "final_year_of_manufacture": null, "raw": ["009428", "000039", "0", "2012/Mar/27 10:12", "Aquaflame", "Aquaflame", "Evolution II 50", "", "", "2002", "current", "4", "1", "1", "1", "0", "", "", "1", "3", "1", "14.4", "14.4", "", "", "85.0", "73.3", "", "53.6", "", "2", "", "", "201", "1", "1", "100", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "84.8", "85.3", "", "", "", "", "85.2"]} -{"pcdb_id": 9430, "brand_name": "Aquaflame", "model_name": "Eco-Avance II 15", "model_qualifier": "", "winter_efficiency_pct": 87.1, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 15.0, "final_year_of_manufacture": null, "raw": ["009430", "000039", "0", "2012/Mar/27 10:12", "Aquaflame", "Aquaflame", "Eco-Avance II 15", "", "", "2002", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "15", "15.0", "", "", "87.1", "79.3", "", "58.0", "", "2", "", "", "201", "1", "1", "100", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.4", "92.8", "", "", "", "", "92.3"]} -{"pcdb_id": 9432, "brand_name": "Aquaflame", "model_name": "Eco-Avance II 19", "model_qualifier": "", "winter_efficiency_pct": 87.1, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 19.3, "final_year_of_manufacture": null, "raw": ["009432", "000039", "0", "2012/Mar/27 10:12", "Aquaflame", "Aquaflame", "Eco-Avance II 19", "", "", "2002", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "19.3", "19.3", "", "", "87.1", "79.3", "", "58.0", "", "2", "", "", "201", "1", "1", "100", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.4", "92.8", "", "", "", "", "92.3"]} -{"pcdb_id": 9433, "brand_name": "Aquaflame", "model_name": "Eco-Avance II 24", "model_qualifier": "", "winter_efficiency_pct": 87.3, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 24.1, "final_year_of_manufacture": null, "raw": ["009433", "000039", "0", "2012/Mar/27 10:12", "Aquaflame", "Aquaflame", "Eco-Avance II 24", "", "", "2002", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "24.1", "24.1", "", "", "87.3", "79.5", "", "58.0", "", "2", "", "", "201", "1", "1", "100", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.2", "93.1", "", "", "", "", "92.6"]} -{"pcdb_id": 9436, "brand_name": "Aquaflame", "model_name": "Eco-Avance II 27", "model_qualifier": "", "winter_efficiency_pct": 87.3, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 27.0, "final_year_of_manufacture": null, "raw": ["009436", "000039", "0", "2012/Mar/27 10:12", "Aquaflame", "Aquaflame", "Eco-Avance II 27", "", "", "2002", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "27", "27.0", "", "", "87.3", "79.5", "", "58.0", "", "2", "", "", "201", "1", "1", "100", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.5", "93.0", "", "", "", "", "92.6"]} -{"pcdb_id": 9438, "brand_name": "Aquaflame", "model_name": "Eco-Avance II 30", "model_qualifier": "", "winter_efficiency_pct": 87.3, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 31.3, "final_year_of_manufacture": null, "raw": ["009438", "000039", "0", "2012/Mar/27 10:12", "Aquaflame", "Aquaflame", "Eco-Avance II 30", "", "", "2002", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "31.3", "31.3", "", "", "87.3", "79.5", "", "58.0", "", "2", "", "", "201", "1", "1", "100", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.5", "93.0", "", "", "", "", "92.6"]} -{"pcdb_id": 9439, "brand_name": "Aquaflame", "model_name": "Eco-Avance II 38", "model_qualifier": "", "winter_efficiency_pct": 87.1, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 37.8, "final_year_of_manufacture": null, "raw": ["009439", "000039", "0", "2012/Mar/27 10:12", "Aquaflame", "Aquaflame", "Eco-Avance II 38", "", "", "2002", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "37.8", "37.8", "", "", "87.1", "79.3", "", "57.9", "", "2", "", "", "201", "1", "1", "130", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.0", "92.9", "", "", "", "", "92.3"]} -{"pcdb_id": 9441, "brand_name": "Vokera", "model_name": "Hydra", "model_qualifier": "Hydra 26", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 56.1, "output_kw_max": 26.8, "final_year_of_manufacture": 2010, "raw": ["009441", "000011", "0", "2010/Oct/21 11:04", "Vokera", "Vokera", "Hydra", "Hydra 26", "4709436", "2002", "2010", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "26.8", "26.8", "", "", "88.4", "79.8", "", "56.1", "", "2", "", "", "104", "1", "2", "130", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.5", "97.7", "", "", "", "", "95.9"]} -{"pcdb_id": 9442, "brand_name": "Vokera", "model_name": "Pinnacle", "model_qualifier": "Pinnacle 16", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 16.8, "final_year_of_manufacture": 2010, "raw": ["009442", "000011", "0", "2012/Mar/27 10:12", "Vokera", "Vokera", "Pinnacle", "Pinnacle 16", "4109423", "2002", "2010", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "16.8", "16.8", "", "", "88.2", "79.2", "", "57.8", "", "2", "", "", "102", "1", "2", "130", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "97.3", "", "", "", "", "95.5"]} -{"pcdb_id": 9443, "brand_name": "Vokera", "model_name": "Pinnacle", "model_qualifier": "Pinnacle 26", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 26.8, "final_year_of_manufacture": 2010, "raw": ["009443", "000011", "0", "2012/Mar/27 10:12", "Vokera", "Vokera", "Pinnacle", "Pinnacle 26", "4109424", "2002", "2010", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "26.8", "26.8", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.5", "97.7", "", "", "", "", "95.9"]} -{"pcdb_id": 9446, "brand_name": "Firebird", "model_name": "Rhino", "model_qualifier": "200-250 Boilerhouse", "winter_efficiency_pct": 86.2, "summer_efficiency_pct": 74.5, "comparative_hot_water_efficiency_pct": 54.4, "output_kw_max": null, "final_year_of_manufacture": 2013, "raw": ["009446", "000223", "0", "2018/Jan/08 09:55", "Firebird Boilers", "Firebird", "Rhino", "200-250 Boilerhouse", "", "", "2013", "4", "1", "1", "1", "0", "", "", "1", "2", "1", "58.61", ">70kW", "", "", "86.2", "74.5", "", "54.4", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.5", "86.9", "", "", "", "", "86.6"]} -{"pcdb_id": 9447, "brand_name": "Firebird", "model_name": "Rhino", "model_qualifier": "200-250 Kitchen", "winter_efficiency_pct": 86.2, "summer_efficiency_pct": 74.5, "comparative_hot_water_efficiency_pct": 54.4, "output_kw_max": null, "final_year_of_manufacture": 2013, "raw": ["009447", "000223", "0", "2018/Jan/08 09:54", "Firebird Boilers", "Firebird", "Rhino", "200-250 Kitchen", "", "", "2013", "4", "1", "1", "1", "0", "", "", "1", "2", "1", "58.61", ">70kW", "", "", "86.2", "74.5", "", "54.4", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.5", "86.9", "", "", "", "", "86.6"]} -{"pcdb_id": 9448, "brand_name": "Firebird", "model_name": "Rhino", "model_qualifier": "150-200 Boilerhouse", "winter_efficiency_pct": 86.4, "summer_efficiency_pct": 74.7, "comparative_hot_water_efficiency_pct": 54.6, "output_kw_max": 58.61, "final_year_of_manufacture": 2013, "raw": ["009448", "000223", "0", "2018/Jan/08 10:09", "Firebird Boilers", "Firebird", "Rhino", "150-200 Boilerhouse", "", "", "2013", "4", "1", "1", "1", "0", "", "", "1", "2", "1", "43.96", "58.61", "", "", "86.4", "74.7", "", "54.6", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.1", "86.7", "", "", "", "", "86.6"]} -{"pcdb_id": 9449, "brand_name": "Firebird", "model_name": "Rhino", "model_qualifier": "150-200 Kitchen", "winter_efficiency_pct": 86.4, "summer_efficiency_pct": 74.7, "comparative_hot_water_efficiency_pct": 54.6, "output_kw_max": 58.61, "final_year_of_manufacture": 2013, "raw": ["009449", "000223", "0", "2018/Jan/08 10:08", "Firebird Boilers", "Firebird", "Rhino", "150-200 Kitchen", "", "", "2013", "4", "1", "1", "1", "0", "", "", "1", "2", "1", "43.96", "58.61", "", "", "86.4", "74.7", "", "54.6", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.1", "86.7", "", "", "", "", "86.6"]} -{"pcdb_id": 9450, "brand_name": "Firebird", "model_name": "Rhino", "model_qualifier": "120-150 Boilerhouse", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 43.96, "final_year_of_manufacture": 2013, "raw": ["009450", "000223", "0", "2018/Jan/08 10:13", "Firebird Boilers", "Firebird", "Rhino", "120-150 Boilerhouse", "", "", "2013", "4", "1", "1", "1", "0", "", "", "1", "2", "1", "36.63", "43.96", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.3", "87.2", "", "", "", "", "87.1"]} -{"pcdb_id": 9451, "brand_name": "Firebird", "model_name": "Rhino", "model_qualifier": "120-150 Kitchen", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 43.96, "final_year_of_manufacture": 2013, "raw": ["009451", "000223", "0", "2018/Jan/08 10:13", "Firebird Boilers", "Firebird", "Rhino", "120-150 Kitchen", "", "", "2013", "4", "1", "1", "1", "0", "", "", "1", "2", "1", "36.63", "43.96", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.3", "87.2", "", "", "", "", "87.1"]} -{"pcdb_id": 9452, "brand_name": "Firebird", "model_name": "Rhino", "model_qualifier": "90-120 Boilerhouse", "winter_efficiency_pct": 86.4, "summer_efficiency_pct": 74.7, "comparative_hot_water_efficiency_pct": 54.6, "output_kw_max": 35.17, "final_year_of_manufacture": 2013, "raw": ["009452", "000223", "0", "2018/Jan/08 10:07", "Firebird Boilers", "Firebird", "Rhino", "90-120 Boilerhouse", "", "", "2013", "4", "1", "1", "1", "0", "", "", "1", "2", "1", "26.38", "35.17", "", "", "86.4", "74.7", "", "54.6", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.4", "86.7", "", "", "", "", "86.6"]} -{"pcdb_id": 9453, "brand_name": "Firebird", "model_name": "Rhino", "model_qualifier": "90-120 Kitchen", "winter_efficiency_pct": 86.4, "summer_efficiency_pct": 74.7, "comparative_hot_water_efficiency_pct": 54.6, "output_kw_max": 35.17, "final_year_of_manufacture": 2013, "raw": ["009453", "000223", "0", "2018/Jan/08 10:06", "Firebird Boilers", "Firebird", "Rhino", "90-120 Kitchen", "", "", "2013", "4", "1", "1", "1", "0", "", "", "1", "2", "1", "26.38", "35.17", "", "", "86.4", "74.7", "", "54.6", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.4", "86.7", "", "", "", "", "86.6"]} -{"pcdb_id": 9454, "brand_name": "Firebird", "model_name": "Rhino", "model_qualifier": "50-90 Boilerhouse", "winter_efficiency_pct": 86.1, "summer_efficiency_pct": 74.4, "comparative_hot_water_efficiency_pct": 54.4, "output_kw_max": 26.38, "final_year_of_manufacture": 2013, "raw": ["009454", "000223", "0", "2018/Jan/08 09:53", "Firebird Boilers", "Firebird", "Rhino", "50-90 Boilerhouse", "", "", "2013", "4", "1", "2", "1", "0", "", "", "1", "1", "1", "14.65", "26.38", "", "", "86.1", "74.4", "", "54.4", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.8", "86.4", "", "", "", "", "86.3"]} -{"pcdb_id": 9455, "brand_name": "Firebird", "model_name": "Rhino", "model_qualifier": "50-90 Kitchen", "winter_efficiency_pct": 86.1, "summer_efficiency_pct": 74.4, "comparative_hot_water_efficiency_pct": 54.4, "output_kw_max": 26.38, "final_year_of_manufacture": 2013, "raw": ["009455", "000223", "0", "2018/Jan/08 09:52", "Firebird Boilers", "Firebird", "Rhino", "50-90 Kitchen", "", "", "2013", "4", "1", "2", "1", "0", "", "", "1", "1", "1", "14.65", "26.38", "", "", "86.1", "74.4", "", "54.4", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.8", "86.4", "", "", "", "", "86.3"]} -{"pcdb_id": 9456, "brand_name": "Firebird", "model_name": "Rhino Heatpac", "model_qualifier": "90-120", "winter_efficiency_pct": 86.4, "summer_efficiency_pct": 74.7, "comparative_hot_water_efficiency_pct": 54.6, "output_kw_max": 35.17, "final_year_of_manufacture": 2013, "raw": ["009456", "000223", "0", "2018/Jan/08 09:50", "Firebird Boilers", "Firebird", "Rhino Heatpac", "90-120", "", "", "2013", "4", "1", "1", "1", "0", "", "", "1", "2", "1", "26.38", "35.17", "", "", "86.4", "74.7", "", "54.6", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.4", "86.7", "", "", "", "", "86.6"]} -{"pcdb_id": 9457, "brand_name": "Firebird", "model_name": "Rhino Heatpac", "model_qualifier": "50-90", "winter_efficiency_pct": 86.1, "summer_efficiency_pct": 74.4, "comparative_hot_water_efficiency_pct": 54.4, "output_kw_max": 26.38, "final_year_of_manufacture": 2013, "raw": ["009457", "000223", "0", "2018/Jan/08 09:46", "Firebird Boilers", "Firebird", "Rhino Heatpac", "50-90", "", "", "2013", "4", "1", "2", "1", "0", "", "", "1", "1", "1", "14.65", "26.38", "", "", "86.1", "74.4", "", "54.4", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.8", "86.4", "", "", "", "", "86.3"]} -{"pcdb_id": 9458, "brand_name": "Firebird", "model_name": "Rhino Slimline Heatpac", "model_qualifier": "50/90", "winter_efficiency_pct": 86.1, "summer_efficiency_pct": 74.4, "comparative_hot_water_efficiency_pct": 54.4, "output_kw_max": 26.38, "final_year_of_manufacture": 2013, "raw": ["009458", "000223", "0", "2018/Jan/08 09:48", "Firebird Boilers", "Firebird", "Rhino Slimline Heatpac", "50/90", "", "", "2013", "4", "1", "2", "1", "0", "", "", "1", "1", "1", "14.65", "26.38", "", "", "86.1", "74.4", "", "54.4", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.8", "86.4", "", "", "", "", "86.3"]} -{"pcdb_id": 9460, "brand_name": "Vaillant", "model_name": "Turbomax Plus", "model_qualifier": "837 E", "winter_efficiency_pct": 80.7, "summer_efficiency_pct": 70.6, "comparative_hot_water_efficiency_pct": 49.6, "output_kw_max": 28.0, "final_year_of_manufacture": 2010, "raw": ["009460", "000031", "0", "2010/Jan/28 08:41", "Vaillant", "Vaillant", "Turbomax Plus", "837 E", "VUW GB 362/2 - 5", "2002", "2010", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "28.0", "28.0", "", "", "80.7", "70.6", "", "49.6", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.0", "81.8", "", "", "", "", "81.8"]} -{"pcdb_id": 9461, "brand_name": "Vaillant", "model_name": "Ecomax", "model_qualifier": "pro 28 E", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 28.2, "final_year_of_manufacture": 2010, "raw": ["009461", "000031", "0", "2012/Mar/27 10:12", "Vaillant", "Vaillant", "Ecomax", "pro 28 E", "VU GB 286 - 0", "2002", "2010", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "28.2", "28.2", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.7", "96.4", "", "", "", "", "95.0"]} -{"pcdb_id": 9462, "brand_name": "Vaillant", "model_name": "Ecomax", "model_qualifier": "pro 18 E", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 78.9, "comparative_hot_water_efficiency_pct": 57.6, "output_kw_max": 18.3, "final_year_of_manufacture": 2010, "raw": ["009462", "000031", "0", "2012/Mar/27 10:12", "Vaillant", "Vaillant", "Ecomax", "pro 18 E", "VU GB 186 - 0", "2002", "2010", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18.3", "18.3", "", "", "87.9", "78.9", "", "57.6", "", "2", "", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.6", "96.3", "", "", "", "", "94.8"]} -{"pcdb_id": 9463, "brand_name": "Saunier Duval", "model_name": "Thema Classic F30E SB", "model_qualifier": "", "winter_efficiency_pct": 80.7, "summer_efficiency_pct": 70.0, "comparative_hot_water_efficiency_pct": 51.1, "output_kw_max": 29.6, "final_year_of_manufacture": null, "raw": ["009463", "000206", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Saunier Duval", "Thema Classic F30E SB", "", "GC 41-920-45", "2002", "current", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "29.6", "29.6", "", "", "80.7", "70.0", "", "51.1", "", "2", "", "", "102", "1", "2", "122", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.2", "81.3", "", "", "", "", "81.4"]} -{"pcdb_id": 9464, "brand_name": "Saunier Duval", "model_name": "Saunier Duval F30E", "model_qualifier": "", "winter_efficiency_pct": 80.5, "summer_efficiency_pct": 70.4, "comparative_hot_water_efficiency_pct": 49.5, "output_kw_max": 29.6, "final_year_of_manufacture": null, "raw": ["009464", "000206", "0", "2006/Jan/17 12:31", "Hepworth Heating", "Saunier Duval", "Saunier Duval F30E", "", "GC 41-920-45", "2002", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "29.6", "29.6", "", "", "80.5", "70.4", "", "49.5", "", "2", "", "", "104", "1", "2", "122", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "0", "0004", "", "", "", "", "", "", "", "", "82.2", "81.3", "", "", "", "", "81.4"]} -{"pcdb_id": 9465, "brand_name": "Glow-worm", "model_name": "30 si", "model_qualifier": "", "winter_efficiency_pct": 80.7, "summer_efficiency_pct": 70.0, "comparative_hot_water_efficiency_pct": 51.1, "output_kw_max": 29.6, "final_year_of_manufacture": null, "raw": ["009465", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "30 si", "", "GC 41-920-45", "2002", "current", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "29.6", "29.6", "", "", "80.7", "70.0", "", "51.1", "", "2", "", "", "102", "1", "2", "122", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.2", "81.3", "", "", "", "", "81.4"]} -{"pcdb_id": 9466, "brand_name": "Glow-worm", "model_name": "30 ci", "model_qualifier": "", "winter_efficiency_pct": 80.5, "summer_efficiency_pct": 70.4, "comparative_hot_water_efficiency_pct": 49.5, "output_kw_max": 29.6, "final_year_of_manufacture": null, "raw": ["009466", "000207", "0", "2012/Feb/20 11:07", "Hepworth Heating", "Glow-worm", "30 ci", "", "GC 41-920-45", "2002", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "29.6", "29.6", "", "", "80.5", "70.4", "", "49.5", "", "2", "", "", "104", "1", "2", "122", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "0", "0004", "", "", "", "", "", "", "", "", "82.2", "81.3", "", "", "", "", "81.4"]} -{"pcdb_id": 9467, "brand_name": "Halstead", "model_name": "Eden sb", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 27.0, "final_year_of_manufacture": null, "raw": ["009467", "000019", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Halstead", "Eden sb", "", "76/BN/726", "2002", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "27.0", "27.0", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.7", "96.4", "", "", "", "", "95.0"]} -{"pcdb_id": 9468, "brand_name": "Halstead", "model_name": "Eden cb", "model_qualifier": "", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 55.8, "output_kw_max": 27.0, "final_year_of_manufacture": null, "raw": ["009468", "000019", "0", "2006/Jun/20 11:47", "Hepworth Heating", "Halstead", "Eden cb", "", "76/BN/729", "2002", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "27.0", "27.0", "", "", "87.9", "79.3", "", "55.8", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.6", "96.3", "", "", "", "", "94.8"]} -{"pcdb_id": 9469, "brand_name": "Halstead", "model_name": "Eden vb", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 27.0, "final_year_of_manufacture": null, "raw": ["009469", "000019", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Halstead", "Eden vb", "", "76/BN/726", "2002", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "27.0", "27.0", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.7", "96.4", "", "", "", "", "95.0"]} -{"pcdb_id": 9473, "brand_name": "Ideal", "model_name": "Buccaneer", "model_qualifier": "GTE6/OIL", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 39.0, "final_year_of_manufacture": null, "raw": ["009473", "000008", "0", "2012/Mar/27 10:12", "DeDietrich", "Ideal", "Buccaneer", "GTE6/OIL", "", "2002", "current", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "32", "39", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.5", "87.8", "", "", "", "", "87.5"]} -{"pcdb_id": 9474, "brand_name": "Ideal", "model_name": "Buccaneer", "model_qualifier": "GTE5/OIL", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 33.0, "final_year_of_manufacture": null, "raw": ["009474", "000008", "0", "2012/Mar/27 10:12", "DeDietrich", "Ideal", "Buccaneer", "GTE5/OIL", "", "2002", "current", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "27", "33", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.4", "88.5", "", "", "", "", "88.1"]} -{"pcdb_id": 9475, "brand_name": "Ideal", "model_name": "Buccaneer", "model_qualifier": "GTE4/OIL", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 27.0, "final_year_of_manufacture": null, "raw": ["009475", "000008", "0", "2012/Mar/27 10:12", "DeDietrich", "Ideal", "Buccaneer", "GTE4/OIL", "", "2002", "current", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "21", "27", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.6", "89.5", "", "", "", "", "88.9"]} -{"pcdb_id": 9476, "brand_name": "Vokera", "model_name": "Mynute", "model_qualifier": "28e", "winter_efficiency_pct": 81.7, "summer_efficiency_pct": 71.0, "comparative_hot_water_efficiency_pct": 51.8, "output_kw_max": 28.0, "final_year_of_manufacture": 2010, "raw": ["009476", "000011", "0", "2012/Mar/27 10:12", "Vokera", "Vokera", "Mynute", "28e", "4109418", "2002", "2010", "2", "2", "1", "1", "0", "", "", "1", "2", "2", "28", "28", "", "", "81.7", "71.0", "", "51.8", "", "2", "0", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "84.5", "80.9", "", "", "", "", "81.5"]} -{"pcdb_id": 9492, "brand_name": "Ariston", "model_name": "Ecocombi 27 MFFI", "model_qualifier": "microCONDENS Series", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 56.6, "output_kw_max": 27.0, "final_year_of_manufacture": 2007, "raw": ["009492", "000080", "0", "2008/Sep/29 16:04", "Merloni TermoSanitari SpA", "Ariston", "Ecocombi 27 MFFI", "microCONDENS Series", "GC No. 47-116-17", "2002", "2007", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "27", "27", "", "", "89.1", "80.5", "", "56.6", "", "2", "1", "", "104", "1", "2", "130", "7", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.6", "98.8", "", "", "", "", "97.3"]} -{"pcdb_id": 9493, "brand_name": "Ariston", "model_name": "Ecosystem 27 RFFI", "model_qualifier": "microCONDENS Series", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 27.0, "final_year_of_manufacture": 2007, "raw": ["009493", "000080", "0", "2012/Mar/27 10:12", "Merloni TermoSanitari SpA", "Ariston", "Ecosystem 27 RFFI", "microCONDENS Series", "GC No. 41-116-08", "2002", "2007", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "27", "27", "", "", "88.1", "79.1", "", "57.8", "", "2", "", "", "102", "1", "2", "130", "7", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.7", "96.7", "", "", "", "", "95.2"]} -{"pcdb_id": 9494, "brand_name": "Ariston", "model_name": "Ecocombi 27 MFFI", "model_qualifier": "microCONDENS Series", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 55.9, "output_kw_max": 27.0, "final_year_of_manufacture": 2007, "raw": ["009494", "000080", "0", "2007/Jun/18 09:22", "Merloni TermoSanitari SpA", "Ariston", "Ecocombi 27 MFFI", "microCONDENS Series", "GC No. 47-116-17", "2002", "2007", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "27", "27", "", "", "88.1", "79.5", "", "55.9", "", "2", "", "", "104", "1", "2", "130", "7", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.7", "96.7", "", "", "", "", "95.2"]} -{"pcdb_id": 9495, "brand_name": "Halstead", "model_name": "Hero 30", "model_qualifier": "", "winter_efficiency_pct": 80.1, "summer_efficiency_pct": 70.0, "comparative_hot_water_efficiency_pct": 51.1, "output_kw_max": 8.79, "final_year_of_manufacture": 2006, "raw": ["009495", "000019", "0", "2012/Mar/27 10:12", "Halstead Boilers", "Halstead", "Hero 30", "", "HR 30", "2002", "2006", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "8.79", "8.79", "", "", "80.1", "70.0", "", "51.1", "", "2", "", "", "101", "1", "1", "70", "5", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.5", "81.8", "", "", "", "", "81.8"]} -{"pcdb_id": 9496, "brand_name": "Halstead", "model_name": "Hero 40", "model_qualifier": "", "winter_efficiency_pct": 79.5, "summer_efficiency_pct": 69.4, "comparative_hot_water_efficiency_pct": 50.7, "output_kw_max": 11.72, "final_year_of_manufacture": 2006, "raw": ["009496", "000019", "0", "2012/Mar/27 10:12", "Halstead Boilers", "Halstead", "Hero 40", "", "HR 40", "2002", "2006", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "11.72", "11.72", "", "", "79.5", "69.4", "", "50.7", "", "2", "", "", "101", "1", "1", "70", "5", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.4", "80.9", "", "", "", "", "81.0"]} -{"pcdb_id": 9497, "brand_name": "Halstead", "model_name": "Hero 40", "model_qualifier": "", "winter_efficiency_pct": 81.3, "summer_efficiency_pct": 71.2, "comparative_hot_water_efficiency_pct": 52.0, "output_kw_max": 11.72, "final_year_of_manufacture": 2006, "raw": ["009497", "000019", "0", "2012/Mar/27 10:12", "Halstead Boilers", "Halstead", "Hero 40", "", "HRP 40", "2002", "2006", "2", "2", "1", "1", "0", "", "", "1", "2", "2", "11.72", "11.72", "", "", "81.3", "71.2", "", "52.0", "", "2", "1", "", "101", "1", "1", "70", "5", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "83.2", "82.7", "", "", "", "", "82.8"]} -{"pcdb_id": 9498, "brand_name": "Halstead", "model_name": "Hero 50", "model_qualifier": "", "winter_efficiency_pct": 79.4, "summer_efficiency_pct": 69.3, "comparative_hot_water_efficiency_pct": 50.6, "output_kw_max": 14.65, "final_year_of_manufacture": 2006, "raw": ["009498", "000019", "0", "2012/Mar/27 10:12", "Halstead Boilers", "Halstead", "Hero 50", "", "HR 50", "2002", "2006", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "14.65", "14.65", "", "", "79.4", "69.3", "", "50.6", "", "2", "", "", "101", "1", "1", "70", "5", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "80.9", "81.0", "", "", "", "", "81.0"]} -{"pcdb_id": 9499, "brand_name": "Halstead", "model_name": "Hero 60", "model_qualifier": "", "winter_efficiency_pct": 80.0, "summer_efficiency_pct": 69.9, "comparative_hot_water_efficiency_pct": 51.1, "output_kw_max": 17.58, "final_year_of_manufacture": 2006, "raw": ["009499", "000019", "0", "2012/Mar/27 10:12", "Halstead Boilers", "Halstead", "Hero 60", "", "HR 60", "2002", "2006", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "17.58", "17.58", "", "", "80.0", "69.9", "", "51.1", "", "2", "", "", "101", "1", "1", "70", "5", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.3", "82.0", "", "", "", "", "81.9"]} -{"pcdb_id": 9500, "brand_name": "Halstead", "model_name": "Hero 60", "model_qualifier": "", "winter_efficiency_pct": 81.8, "summer_efficiency_pct": 71.7, "comparative_hot_water_efficiency_pct": 52.4, "output_kw_max": 17.58, "final_year_of_manufacture": 2006, "raw": ["009500", "000019", "0", "2012/Mar/27 10:12", "Halstead Boilers", "Halstead", "Hero 60", "", "HRP 60", "2002", "2006", "2", "2", "1", "1", "0", "", "", "1", "2", "2", "17.58", "17.58", "", "", "81.8", "71.7", "", "52.4", "", "2", "1", "", "101", "1", "1", "70", "5", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "83.1", "83.8", "", "", "", "", "83.7"]} -{"pcdb_id": 9501, "brand_name": "Halstead", "model_name": "Hero 75", "model_qualifier": "", "winter_efficiency_pct": 79.3, "summer_efficiency_pct": 69.2, "comparative_hot_water_efficiency_pct": 50.6, "output_kw_max": 22.0, "final_year_of_manufacture": 2006, "raw": ["009501", "000019", "0", "2012/Mar/27 10:12", "Halstead Boilers", "Halstead", "Hero 75", "", "HR 75", "2002", "2006", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "22", "22.0", "", "", "79.3", "69.2", "", "50.6", "", "2", "", "", "101", "1", "1", "85", "5", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "80.9", "80.9", "", "", "", "", "80.9"]} -{"pcdb_id": 9502, "brand_name": "Halstead", "model_name": "Hero 90", "model_qualifier": "", "winter_efficiency_pct": 79.5, "summer_efficiency_pct": 69.4, "comparative_hot_water_efficiency_pct": 50.7, "output_kw_max": 26.37, "final_year_of_manufacture": 2006, "raw": ["009502", "000019", "0", "2012/Mar/27 10:12", "Halstead Boilers", "Halstead", "Hero 90", "", "HR 90", "2002", "2006", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "26.37", "26.37", "", "", "79.5", "69.4", "", "50.7", "", "2", "", "", "101", "1", "1", "85", "5", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.1", "81.1", "", "", "", "", "81.1"]} -{"pcdb_id": 9503, "brand_name": "Saunier Duval", "model_name": "Thema Classic F30E Plus", "model_qualifier": "", "winter_efficiency_pct": 80.5, "summer_efficiency_pct": 70.4, "comparative_hot_water_efficiency_pct": 55.0, "output_kw_max": 29.6, "final_year_of_manufacture": null, "raw": ["009503", "000206", "0", "2006/Jan/17 12:31", "Hepworth Heating", "Saunier Duval", "Thema Classic F30E Plus", "", "GC 47-920-38", "2002", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "29.6", "29.6", "", "", "80.5", "70.4", "", "55.0", "", "2", "", "", "104", "1", "2", "122", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "3", "1", "30", "0004", "", "", "", "", "", "", "", "", "82.2", "81.3", "", "", "", "", "81.4"]} -{"pcdb_id": 9504, "brand_name": "Saunier Duval", "model_name": "Thema Classic F24E Plus", "model_qualifier": "", "winter_efficiency_pct": 79.2, "summer_efficiency_pct": 69.1, "comparative_hot_water_efficiency_pct": 54.0, "output_kw_max": 23.6, "final_year_of_manufacture": null, "raw": ["009504", "000206", "0", "2006/Jan/17 12:31", "Hepworth Heating", "Saunier Duval", "Thema Classic F24E Plus", "", "GC 47-920-37", "2001", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "23.6", "23.6", "", "", "79.2", "69.1", "", "54.0", "", "2", "", "", "104", "1", "2", "122", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "3", "1", "30", "0004", "", "", "", "", "", "", "", "", "81.4", "79.5", "", "", "", "", "79.8"]} -{"pcdb_id": 9505, "brand_name": "Glow-worm", "model_name": "30ci Plus", "model_qualifier": "", "winter_efficiency_pct": 80.5, "summer_efficiency_pct": 70.4, "comparative_hot_water_efficiency_pct": 55.0, "output_kw_max": 29.6, "final_year_of_manufacture": null, "raw": ["009505", "000207", "0", "2006/Jan/17 12:31", "Hepworth Heating", "Glow-worm", "30ci Plus", "", "GC 47-047-22", "2002", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "29.6", "29.6", "", "", "80.5", "70.4", "", "55.0", "", "2", "", "", "104", "1", "2", "122", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "3", "1", "30", "0004", "", "", "", "", "", "", "", "", "82.2", "81.3", "", "", "", "", "81.4"]} -{"pcdb_id": 9506, "brand_name": "Glow-worm", "model_name": "24ci Plus", "model_qualifier": "", "winter_efficiency_pct": 79.2, "summer_efficiency_pct": 69.1, "comparative_hot_water_efficiency_pct": 54.0, "output_kw_max": 23.6, "final_year_of_manufacture": 2003, "raw": ["009506", "000207", "0", "2006/Jan/17 12:55", "Hepworth Heating", "Glow-worm", "24ci Plus", "", "GC 47-047-21", "2001", "2003", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "23.6", "23.6", "", "", "79.2", "69.1", "", "54.0", "", "2", "", "", "104", "1", "2", "122", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "3", "1", "30", "0004", "", "", "", "", "", "", "", "", "81.4", "79.5", "", "", "", "", "79.8"]} -{"pcdb_id": 9507, "brand_name": "Potterton", "model_name": "Performa System", "model_qualifier": "12e", "winter_efficiency_pct": 79.9, "summer_efficiency_pct": 69.2, "comparative_hot_water_efficiency_pct": 50.6, "output_kw_max": 12.4, "final_year_of_manufacture": 2006, "raw": ["009507", "000005", "0", "2012/Mar/27 10:12", "Baxi Potterton", "Potterton", "Performa System", "12e", "GC No. 41-590-88", "2002", "2006", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "12.4", "12.4", "", "", "79.9", "69.2", "", "50.6", "", "2", "", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.1", "79.7", "", "", "", "", "80.2"]} -{"pcdb_id": 9508, "brand_name": "Potterton", "model_name": "Performa System", "model_qualifier": "18e", "winter_efficiency_pct": 79.8, "summer_efficiency_pct": 69.1, "comparative_hot_water_efficiency_pct": 50.5, "output_kw_max": 17.5, "final_year_of_manufacture": 2006, "raw": ["009508", "000005", "0", "2012/Mar/27 10:12", "Baxi Potterton", "Potterton", "Performa System", "18e", "GC No. 41-590-89", "2002", "2006", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "17.5", "17.5", "", "", "79.8", "69.1", "", "50.5", "", "2", "", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.1", "79.6", "", "", "", "", "80.0"]} -{"pcdb_id": 9509, "brand_name": "Potterton", "model_name": "Performa System", "model_qualifier": "24e", "winter_efficiency_pct": 79.7, "summer_efficiency_pct": 69.0, "comparative_hot_water_efficiency_pct": 50.4, "output_kw_max": 24.0, "final_year_of_manufacture": 2006, "raw": ["009509", "000005", "0", "2012/Mar/27 10:12", "Baxi Potterton", "Potterton", "Performa System", "24e", "GC No. 41-590-90", "2002", "2006", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "24", "24", "", "", "79.7", "69.0", "", "50.4", "", "2", "", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.2", "79.2", "", "", "", "", "79.8"]} -{"pcdb_id": 9510, "brand_name": "Potterton", "model_name": "Performa System", "model_qualifier": "28e", "winter_efficiency_pct": 79.2, "summer_efficiency_pct": 68.5, "comparative_hot_water_efficiency_pct": 50.1, "output_kw_max": 29.4, "final_year_of_manufacture": 2005, "raw": ["009510", "000005", "0", "2012/Mar/27 10:12", "Baxi Potterton", "Potterton", "Performa System", "28e", "GC No. 41-590-91", "2002", "2005", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "29.4", "29.4", "", "", "79.2", "68.5", "", "50.1", "", "2", "", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.2", "79.3", "", "", "", "", "79.6"]} -{"pcdb_id": 9511, "brand_name": "Potterton", "model_name": "Performa System", "model_qualifier": "12e", "winter_efficiency_pct": 81.9, "summer_efficiency_pct": 71.2, "comparative_hot_water_efficiency_pct": 52.0, "output_kw_max": 12.4, "final_year_of_manufacture": 2006, "raw": ["009511", "000005", "0", "2012/Mar/27 10:12", "Baxi Potterton", "Potterton", "Performa System", "12e", "GC No. 41-590-88", "2002", "2006", "2", "2", "1", "1", "0", "", "", "1", "2", "2", "12.4", "12.4", "", "", "81.9", "71.2", "", "52.0", "", "2", "0", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "84.2", "81.7", "", "", "", "", "82.2"]} -{"pcdb_id": 9512, "brand_name": "Potterton", "model_name": "Performa System", "model_qualifier": "18e", "winter_efficiency_pct": 81.8, "summer_efficiency_pct": 71.1, "comparative_hot_water_efficiency_pct": 52.0, "output_kw_max": 17.5, "final_year_of_manufacture": 2006, "raw": ["009512", "000005", "0", "2012/Mar/27 10:12", "Baxi Potterton", "Potterton", "Performa System", "18e", "GC No. 41-590-89", "2002", "2006", "2", "2", "1", "1", "0", "", "", "1", "2", "2", "17.5", "17.5", "", "", "81.8", "71.1", "", "52.0", "", "2", "0", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "84.2", "81.5", "", "", "", "", "82.0"]} -{"pcdb_id": 9513, "brand_name": "Potterton", "model_name": "Performa System", "model_qualifier": "24e", "winter_efficiency_pct": 81.8, "summer_efficiency_pct": 71.1, "comparative_hot_water_efficiency_pct": 51.9, "output_kw_max": 24.0, "final_year_of_manufacture": 2006, "raw": ["009513", "000005", "0", "2012/Mar/27 10:12", "Baxi Potterton", "Potterton", "Performa System", "24e", "GC No. 41-590-90", "2002", "2006", "2", "2", "1", "1", "0", "", "", "1", "2", "2", "24", "24", "", "", "81.8", "71.1", "", "51.9", "", "2", "0", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "84.3", "81.3", "", "", "", "", "81.9"]} -{"pcdb_id": 9514, "brand_name": "Potterton", "model_name": "Performa System", "model_qualifier": "28e", "winter_efficiency_pct": 81.4, "summer_efficiency_pct": 70.7, "comparative_hot_water_efficiency_pct": 51.7, "output_kw_max": 29.4, "final_year_of_manufacture": 2005, "raw": ["009514", "000005", "0", "2012/Mar/27 10:12", "Baxi Potterton", "Potterton", "Performa System", "28e", "GC No. 41-590-91", "2002", "2005", "2", "2", "1", "1", "0", "", "", "1", "2", "2", "29.4", "29.4", "", "", "81.4", "70.7", "", "51.7", "", "2", "0", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "83.4", "81.4", "", "", "", "", "81.8"]} -{"pcdb_id": 9515, "brand_name": "Clyde", "model_name": "GB112-43", "model_qualifier": "", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 78.9, "comparative_hot_water_efficiency_pct": 57.6, "output_kw_max": 42.9, "final_year_of_manufacture": null, "raw": ["009515", "000012", "0", "2012/Mar/27 10:12", "Clyde Combustions", "Clyde", "GB112-43", "", "", "2002", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "42.9", "42.9", "", "", "87.9", "78.9", "", "57.6", "", "2", "", "", "102", "1", "2", "180", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.1", "96.4", "", "", "", "", "94.8"]} -{"pcdb_id": 9516, "brand_name": "Clyde", "model_name": "GB112-60", "model_qualifier": "", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 78.9, "comparative_hot_water_efficiency_pct": 57.6, "output_kw_max": 55.1, "final_year_of_manufacture": null, "raw": ["009516", "000012", "0", "2012/Mar/27 10:12", "Clyde Combustions", "Clyde", "GB112-60", "", "", "2002", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "55.1", "55.1", "", "", "87.9", "78.9", "", "57.6", "", "2", "", "", "102", "1", "2", "200", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "96.5", "", "", "", "", "94.9"]} -{"pcdb_id": 9517, "brand_name": "Geminox", "model_name": "FCX", "model_qualifier": "", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 78.9, "comparative_hot_water_efficiency_pct": 57.6, "output_kw_max": 23.9, "final_year_of_manufacture": null, "raw": ["009517", "000212", "0", "2012/Mar/27 10:12", "Geminox SA", "Geminox", "FCX", "", "", "1998", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "19.2", "23.9", "", "", "86.7", "78.9", "", "57.6", "", "2", "", "", "201", "1", "1", "210", "15", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "89.3", "92.2", "", "", "", "", "91.6"]} -{"pcdb_id": 9519, "brand_name": "Sime", "model_name": "Format System 24", "model_qualifier": "", "winter_efficiency_pct": 80.1, "summer_efficiency_pct": 69.4, "comparative_hot_water_efficiency_pct": 50.7, "output_kw_max": 23.4, "final_year_of_manufacture": 2018, "raw": ["009519", "000213", "0", "2018/Feb/28 16:57", "Fonderie Sime S.p.A.", "Sime", "Format System 24", "", "", "2002", "2018", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "23.4", "23.4", "", "", "80.1", "69.4", "", "50.7", "", "2", "", "", "102", "1", "2", "150", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.7", "80.5", "", "", "", "", "80.8"]} -{"pcdb_id": 9520, "brand_name": "Sime", "model_name": "Format System 30", "model_qualifier": "", "winter_efficiency_pct": 80.3, "summer_efficiency_pct": 69.6, "comparative_hot_water_efficiency_pct": 50.8, "output_kw_max": 28.8, "final_year_of_manufacture": 2018, "raw": ["009520", "000213", "0", "2018/Feb/28 17:02", "Fonderie Sime S.p.A.", "Sime", "Format System 30", "", "", "2002", "2018", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "28.8", "28.8", "", "", "80.3", "69.6", "", "50.8", "", "2", "", "", "102", "1", "2", "160", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.0", "80.5", "", "", "", "", "80.8"]} -{"pcdb_id": 9521, "brand_name": "Sime", "model_name": "Format System 24 EI", "model_qualifier": "", "winter_efficiency_pct": 80.1, "summer_efficiency_pct": 69.4, "comparative_hot_water_efficiency_pct": 50.7, "output_kw_max": 23.4, "final_year_of_manufacture": 2018, "raw": ["009521", "000213", "0", "2018/Feb/28 16:58", "Fonderie Sime S.p.A.", "Sime", "Format System 24 EI", "", "", "2002", "2018", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "23.4", "23.4", "", "", "80.1", "69.4", "", "50.7", "", "2", "", "", "102", "1", "2", "150", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.7", "80.5", "", "", "", "", "80.8"]} -{"pcdb_id": 9522, "brand_name": "Sime", "model_name": "Format System 30 EI", "model_qualifier": "", "winter_efficiency_pct": 80.3, "summer_efficiency_pct": 69.6, "comparative_hot_water_efficiency_pct": 50.8, "output_kw_max": 28.8, "final_year_of_manufacture": 2018, "raw": ["009522", "000213", "0", "2018/Mar/05 14:00", "Fonderie Sime S.p.A.", "Sime", "Format System 30 EI", "", "", "2002", "2018", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "28.8", "28.8", "", "", "80.3", "69.6", "", "50.8", "", "2", "", "", "102", "1", "2", "160", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.0", "80.5", "", "", "", "", "80.8"]} -{"pcdb_id": 9523, "brand_name": "Sime", "model_name": "Format System 24", "model_qualifier": "", "winter_efficiency_pct": 81.9, "summer_efficiency_pct": 71.2, "comparative_hot_water_efficiency_pct": 52.0, "output_kw_max": 23.4, "final_year_of_manufacture": 2018, "raw": ["009523", "000213", "0", "2018/Feb/28 16:57", "Fonderie Sime S.p.A.", "Sime", "Format System 24", "", "LPG", "2002", "2018", "2", "2", "1", "1", "0", "", "", "1", "2", "2", "23.4", "23.4", "", "", "81.9", "71.2", "", "52.0", "", "2", "1", "", "102", "1", "2", "150", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "83.5", "82.3", "", "", "", "", "82.6"]} -{"pcdb_id": 9524, "brand_name": "Sime", "model_name": "Format System 30", "model_qualifier": "", "winter_efficiency_pct": 82.1, "summer_efficiency_pct": 71.4, "comparative_hot_water_efficiency_pct": 52.1, "output_kw_max": 28.8, "final_year_of_manufacture": 2018, "raw": ["009524", "000213", "0", "2018/Mar/05 14:00", "Fonderie Sime S.p.A.", "Sime", "Format System 30", "", "LPG", "2002", "2018", "2", "2", "1", "1", "0", "", "", "1", "2", "2", "28.8", "28.8", "", "", "82.1", "71.4", "", "52.1", "", "2", "1", "", "102", "1", "2", "160", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "83.8", "82.3", "", "", "", "", "82.6"]} -{"pcdb_id": 9525, "brand_name": "Sime", "model_name": "Format System 24 EI", "model_qualifier": "", "winter_efficiency_pct": 81.9, "summer_efficiency_pct": 71.2, "comparative_hot_water_efficiency_pct": 52.0, "output_kw_max": 23.4, "final_year_of_manufacture": 2018, "raw": ["009525", "000213", "0", "2018/Feb/28 16:58", "Fonderie Sime S.p.A.", "Sime", "Format System 24 EI", "", "LPG", "2002", "2018", "2", "2", "1", "1", "0", "", "", "1", "2", "2", "23.4", "23.4", "", "", "81.9", "71.2", "", "52.0", "", "2", "1", "", "102", "1", "2", "150", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "83.5", "82.3", "", "", "", "", "82.6"]} -{"pcdb_id": 9526, "brand_name": "Sime", "model_name": "Format System 30 EI", "model_qualifier": "", "winter_efficiency_pct": 82.1, "summer_efficiency_pct": 71.4, "comparative_hot_water_efficiency_pct": 52.1, "output_kw_max": 28.8, "final_year_of_manufacture": 2018, "raw": ["009526", "000213", "0", "2018/Mar/05 14:01", "Fonderie Sime S.p.A.", "Sime", "Format System 30 EI", "", "LPG", "2002", "2018", "2", "2", "1", "1", "0", "", "", "1", "2", "2", "28.8", "28.8", "", "", "82.1", "71.4", "", "52.1", "", "2", "1", "", "102", "1", "2", "160", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "83.8", "82.3", "", "", "", "", "82.6"]} -{"pcdb_id": 9527, "brand_name": "Broag Remeha", "model_name": "Quinta", "model_qualifier": "Quinta 30", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 28.0, "final_year_of_manufacture": null, "raw": ["009527", "000006", "0", "2012/Mar/27 10:12", "Remeha", "Broag Remeha", "Quinta", "Quinta 30", "0063BM3043", "2000", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "28", "28", "", "", "88.5", "79.5", "", "58.1", "", "2", "", "", "102", "1", "2", "46", "10", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "98.0", "", "", "", "", "96.2"]} -{"pcdb_id": 9529, "brand_name": "Broag Remeha", "model_name": "Quinta", "model_qualifier": "Quinta 30", "winter_efficiency_pct": 89.5, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 58.8, "output_kw_max": 28.0, "final_year_of_manufacture": null, "raw": ["009529", "000006", "0", "2012/Mar/27 10:12", "Remeha", "Broag Remeha", "Quinta", "Quinta 30", "0063BM3043", "2000", "current", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "28", "28", "", "", "89.5", "80.5", "", "58.8", "", "2", "1", "", "102", "1", "2", "46", "10", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.3", "100.2", "", "", "", "", "98.3"]} -{"pcdb_id": 9531, "brand_name": "Chaffoteaux et Maury", "model_name": "Centora Green System 30", "model_qualifier": "", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 78.9, "comparative_hot_water_efficiency_pct": 57.6, "output_kw_max": 30.0, "final_year_of_manufacture": 2007, "raw": ["009531", "000010", "0", "2012/Mar/27 10:12", "Chaffoteaux et Maury", "Chaffoteaux et Maury", "Centora Green System 30", "", "CG No. 41-980-31", "2002", "2007", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "30", "30", "", "", "87.9", "78.9", "", "57.6", "", "2", "", "", "102", "1", "2", "150", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "96.4", "", "", "", "", "94.8"]} -{"pcdb_id": 9532, "brand_name": "Chaffoteaux et Maury", "model_name": "Centora Green 30", "model_qualifier": "", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 55.7, "output_kw_max": 30.0, "final_year_of_manufacture": 2007, "raw": ["009532", "000010", "0", "2007/Jun/18 09:14", "Chaffoteaux et Maury", "Chaffoteaux et Maury", "Centora Green 30", "", "GC No. 47-980-24", "2002", "2007", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "30", "30", "", "", "87.9", "79.3", "", "55.7", "", "2", "", "", "104", "1", "2", "150", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "96.4", "", "", "", "", "94.8"]} -{"pcdb_id": 9533, "brand_name": "Chaffoteaux et Maury", "model_name": "Calydra Green 30", "model_qualifier": "", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 55.7, "output_kw_max": 30.0, "final_year_of_manufacture": 2007, "raw": ["009533", "000010", "0", "2007/Jun/18 09:14", "Chaffoteaux et Maury", "Chaffoteaux et Maury", "Calydra Green 30", "", "GC No. 47-980-26", "2002", "2007", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "30", "30", "", "", "87.9", "79.3", "", "55.7", "", "2", "", "", "104", "1", "2", "150", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "96.4", "", "", "", "", "94.8"]} -{"pcdb_id": 9534, "brand_name": "Sile SpA", "model_name": "Turbinox 21 N", "model_qualifier": "", "winter_efficiency_pct": 81.6, "summer_efficiency_pct": 70.9, "comparative_hot_water_efficiency_pct": 51.8, "output_kw_max": 23.5, "final_year_of_manufacture": null, "raw": ["009534", "000221", "0", "2012/Mar/27 10:12", "Sile SpA", "Sile SpA", "Turbinox 21 N", "", "", "2002", "current", "2", "2", "1", "1", "0", "", "", "1", "2", "2", "23.50", "23.50", "", "", "81.6", "70.9", "", "51.8", "", "2", "0", "", "102", "1", "2", "140", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "84.0", "81.2", "", "", "", "", "81.8"]} -{"pcdb_id": 9535, "brand_name": "Sile SpA", "model_name": "Turbinox 25 N", "model_qualifier": "", "winter_efficiency_pct": 82.3, "summer_efficiency_pct": 71.6, "comparative_hot_water_efficiency_pct": 52.3, "output_kw_max": 26.5, "final_year_of_manufacture": null, "raw": ["009535", "000221", "0", "2012/Mar/27 10:12", "Sile SpA", "Sile SpA", "Turbinox 25 N", "", "", "2002", "current", "2", "2", "1", "1", "0", "", "", "1", "2", "2", "26.50", "26.50", "", "", "82.3", "71.6", "", "52.3", "", "2", "0", "", "102", "1", "2", "140", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "84.7", "81.9", "", "", "", "", "82.4"]} -{"pcdb_id": 9536, "brand_name": "Sile SpA", "model_name": "Turbinox 25 BI", "model_qualifier": "", "winter_efficiency_pct": 82.4, "summer_efficiency_pct": 73.3, "comparative_hot_water_efficiency_pct": 33.0, "output_kw_max": 26.5, "final_year_of_manufacture": null, "raw": ["009536", "000221", "0", "2024/Jan/31 10:17", "Sile SpA", "Sile SpA", "Turbinox 25 BI", "", "", "2002", "current", "2", "2", "1", "2", "0", "", "", "1", "2", "2", "26.50", "26.50", "", "", "82.4", "73.3", "", "33.0", "", "2", "0", "", "106", "1", "2", "140", "0", "2", "", "0", "60", "0", "10", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "84.7", "81.9", "", "", "", "", "82.4"]} -{"pcdb_id": 9537, "brand_name": "Sile SpA", "model_name": "Turbinox 21 BI", "model_qualifier": "", "winter_efficiency_pct": 81.7, "summer_efficiency_pct": 72.6, "comparative_hot_water_efficiency_pct": 33.9, "output_kw_max": 23.5, "final_year_of_manufacture": null, "raw": ["009537", "000221", "0", "2024/Jan/31 10:17", "Sile SpA", "Sile SpA", "Turbinox 21 BI", "", "", "2002", "current", "2", "2", "1", "2", "0", "", "", "1", "2", "2", "23.5", "23.5", "", "", "81.7", "72.6", "", "33.9", "", "2", "0", "", "106", "1", "2", "140", "0", "2", "", "0", "50", "0", "10", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "84.0", "81.2", "", "", "", "", "81.8"]} -{"pcdb_id": 9538, "brand_name": "Sile SpA", "model_name": "Turbinox 21 N", "model_qualifier": "", "winter_efficiency_pct": 80.4, "summer_efficiency_pct": 69.7, "comparative_hot_water_efficiency_pct": 50.9, "output_kw_max": 23.5, "final_year_of_manufacture": null, "raw": ["009538", "000221", "0", "2012/Mar/27 10:12", "Sile SpA", "Sile SpA", "Turbinox 21 N", "", "", "2002", "current", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "23.50", "23.50", "", "", "80.4", "69.7", "", "50.9", "", "2", "", "", "102", "1", "2", "140", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "83.0", "79.9", "", "", "", "", "80.5"]} -{"pcdb_id": 9539, "brand_name": "Sile SpA", "model_name": "Turbinox 25 N", "model_qualifier": "", "winter_efficiency_pct": 80.9, "summer_efficiency_pct": 70.2, "comparative_hot_water_efficiency_pct": 51.2, "output_kw_max": 26.5, "final_year_of_manufacture": null, "raw": ["009539", "000221", "0", "2012/Mar/27 10:12", "Sile SpA", "Sile SpA", "Turbinox 25 N", "", "", "2002", "current", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "26.50", "26.50", "", "", "80.9", "70.2", "", "51.2", "", "2", "", "", "102", "1", "2", "140", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "83.5", "80.8", "", "", "", "", "81.3"]} -{"pcdb_id": 9540, "brand_name": "Sile SpA", "model_name": "Turbinox 25 BI", "model_qualifier": "", "winter_efficiency_pct": 81.0, "summer_efficiency_pct": 71.9, "comparative_hot_water_efficiency_pct": 32.3, "output_kw_max": 26.5, "final_year_of_manufacture": null, "raw": ["009540", "000221", "0", "2024/Jan/31 10:17", "Sile SpA", "Sile SpA", "Turbinox 25 BI", "", "", "2002", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "26.50", "26.50", "", "", "81.0", "71.9", "", "32.3", "", "2", "", "", "106", "1", "2", "140", "0", "2", "", "0", "60", "0", "10", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "83.5", "80.8", "", "", "", "", "81.3"]} -{"pcdb_id": 9541, "brand_name": "Sile SpA", "model_name": "Turbinox 21 BI", "model_qualifier": "", "winter_efficiency_pct": 80.5, "summer_efficiency_pct": 71.4, "comparative_hot_water_efficiency_pct": 33.3, "output_kw_max": 23.5, "final_year_of_manufacture": null, "raw": ["009541", "000221", "0", "2024/Jan/31 10:17", "Sile SpA", "Sile SpA", "Turbinox 21 BI", "", "", "2002", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "23.50", "23.50", "", "", "80.5", "71.4", "", "33.3", "", "2", "", "", "106", "1", "2", "140", "0", "2", "", "0", "50", "0", "10", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "83.0", "79.9", "", "", "", "", "80.5"]} -{"pcdb_id": 9542, "brand_name": "Vokera", "model_name": "Mynute", "model_qualifier": "Mynute 16e LPG", "winter_efficiency_pct": 82.1, "summer_efficiency_pct": 72.0, "comparative_hot_water_efficiency_pct": 52.6, "output_kw_max": 16.0, "final_year_of_manufacture": 2010, "raw": ["009542", "000011", "0", "2012/Mar/27 10:12", "Vokera", "Vokera", "Mynute", "Mynute 16e LPG", "4109422", "2002", "2010", "2", "2", "1", "1", "0", "", "", "1", "2", "2", "12", "16.0", "", "", "82.1", "72.0", "", "52.6", "", "2", "0", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "84.5", "82.8", "", "", "", "", "83.1"]} -{"pcdb_id": 9543, "brand_name": "Vokera", "model_name": "Mynute", "model_qualifier": "Mynute 12e LPG", "winter_efficiency_pct": 82.3, "summer_efficiency_pct": 72.2, "comparative_hot_water_efficiency_pct": 52.8, "output_kw_max": 12.0, "final_year_of_manufacture": 2010, "raw": ["009543", "000011", "0", "2012/Mar/27 10:12", "Vokera", "Vokera", "Mynute", "Mynute 12e LPG", "4109421", "2002", "2010", "2", "2", "1", "1", "0", "", "", "1", "2", "2", "7.4", "12.0", "", "", "82.3", "72.2", "", "52.8", "", "2", "0", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.5", "83.2", "", "", "", "", "83.6"]} -{"pcdb_id": 9544, "brand_name": "Vokera", "model_name": "Pinnacle", "model_qualifier": "Pinnacle 26 LPG", "winter_efficiency_pct": 90.4, "summer_efficiency_pct": 81.4, "comparative_hot_water_efficiency_pct": 59.5, "output_kw_max": 26.8, "final_year_of_manufacture": 2010, "raw": ["009544", "000011", "0", "2012/Mar/27 10:12", "Vokera", "Vokera", "Pinnacle", "Pinnacle 26 LPG", "4109424", "2002", "2010", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "26.8", "26.8", "", "", "90.4", "81.4", "", "59.5", "", "2", "0", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.9", "100.0", "", "", "", "", "98.1"]} -{"pcdb_id": 9545, "brand_name": "Vokera", "model_name": "Hydra", "model_qualifier": "Hydra 26 LPG", "winter_efficiency_pct": 90.4, "summer_efficiency_pct": 81.8, "comparative_hot_water_efficiency_pct": 57.5, "output_kw_max": 26.8, "final_year_of_manufacture": 2010, "raw": ["009545", "000011", "0", "2010/Oct/21 11:05", "Vokera", "Vokera", "Hydra", "Hydra 26 LPG", "4709436", "2002", "2010", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "26.8", "26.8", "", "", "90.4", "81.8", "", "57.5", "", "2", "0", "", "104", "1", "2", "130", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.9", "100.0", "", "", "", "", "98.1"]} -{"pcdb_id": 9546, "brand_name": "Vokera", "model_name": "Pinnacle", "model_qualifier": "Pinnacle 16 LPG", "winter_efficiency_pct": 90.1, "summer_efficiency_pct": 81.1, "comparative_hot_water_efficiency_pct": 59.3, "output_kw_max": 16.8, "final_year_of_manufacture": 2010, "raw": ["009546", "000011", "0", "2012/Mar/27 10:12", "Vokera", "Vokera", "Pinnacle", "Pinnacle 16 LPG", "4109423", "2002", "2010", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "16.8", "16.8", "", "", "90.1", "81.1", "", "59.3", "", "2", "0", "", "102", "1", "2", "130", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.3", "99.5", "", "", "", "", "97.5"]} -{"pcdb_id": 9547, "brand_name": "A J Wells and Sons", "model_name": "Charnwood OLX45 Hearth Boiler", "model_qualifier": "", "winter_efficiency_pct": 83.7, "summer_efficiency_pct": 72.0, "comparative_hot_water_efficiency_pct": 52.6, "output_kw_max": 13.4, "final_year_of_manufacture": null, "raw": ["009547", "000224", "0", "2019/Jul/16 16:10", "A J Wells and Sons", "A J Wells and Sons", "Charnwood OLX45 Hearth Boiler", "", "", "2000", "current", "4", "4", "1", "1", "0", "", "", "1", "1", "2", "11", "13.4", "", "", "83.7", "72.0", "", "52.6", "", "2", "", "", "201", "1", "1", "200", "60", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "84.1", "83.3", "", "", "", "", "83.5"]} -{"pcdb_id": 9548, "brand_name": "Vokera", "model_name": "Compact", "model_qualifier": "24", "winter_efficiency_pct": 81.4, "summer_efficiency_pct": 71.3, "comparative_hot_water_efficiency_pct": 50.1, "output_kw_max": 24.0, "final_year_of_manufacture": null, "raw": ["009548", "000011", "0", "2006/Jan/17 12:31", "Vokera", "Vokera", "Compact", "24", "", "2002", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "24.0", "24.0", "", "", "81.4", "71.3", "", "50.1", "", "2", "", "", "104", "1", "2", "125", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "83.3", "82.3", "", "", "", "", "82.4"]} -{"pcdb_id": 9549, "brand_name": "Vokera", "model_name": "Compact", "model_qualifier": "28", "winter_efficiency_pct": 81.3, "summer_efficiency_pct": 71.2, "comparative_hot_water_efficiency_pct": 50.1, "output_kw_max": 28.0, "final_year_of_manufacture": null, "raw": ["009549", "000011", "0", "2006/Jan/17 12:31", "Vokera", "Vokera", "Compact", "28", "", "2002", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "28.0", "28.0", "", "", "81.3", "71.2", "", "50.1", "", "2", "", "", "104", "1", "2", "125", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "83.3", "82.2", "", "", "", "", "82.4"]} -{"pcdb_id": 9550, "brand_name": "Vokera", "model_name": "Compact", "model_qualifier": "24 LPG", "winter_efficiency_pct": 83.1, "summer_efficiency_pct": 73.0, "comparative_hot_water_efficiency_pct": 51.3, "output_kw_max": 24.0, "final_year_of_manufacture": null, "raw": ["009550", "000011", "0", "2006/Jan/17 12:31", "Vokera", "Vokera", "Compact", "24 LPG", "", "2002", "current", "2", "2", "1", "2", "0", "", "", "1", "2", "2", "24.0", "24.0", "", "", "83.1", "73.0", "", "51.3", "", "2", "0", "", "104", "1", "2", "125", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "84.9", "83.8", "", "", "", "", "84.0"]} -{"pcdb_id": 9551, "brand_name": "Vokera", "model_name": "Compact", "model_qualifier": "28 LPG", "winter_efficiency_pct": 82.7, "summer_efficiency_pct": 72.6, "comparative_hot_water_efficiency_pct": 51.1, "output_kw_max": 28.0, "final_year_of_manufacture": null, "raw": ["009551", "000011", "0", "2006/Jan/17 12:31", "Vokera", "Vokera", "Compact", "28 LPG", "", "2002", "current", "2", "2", "1", "2", "0", "", "", "1", "2", "2", "28.0", "28.0", "", "", "82.7", "72.6", "", "51.1", "", "2", "0", "", "104", "1", "2", "125", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "84.5", "83.4", "", "", "", "", "83.6"]} -{"pcdb_id": 9552, "brand_name": "Sime", "model_name": "Format 110 C", "model_qualifier": "", "winter_efficiency_pct": 79.3, "summer_efficiency_pct": 69.2, "comparative_hot_water_efficiency_pct": 48.7, "output_kw_max": 31.6, "final_year_of_manufacture": 2018, "raw": ["009552", "000213", "0", "2018/Feb/26 17:00", "Fonderie Sime S.p.A.", "Sime", "Format 110 C", "", "", "2003", "2018", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "31.6", "31.6", "", "", "79.3", "69.2", "", "48.7", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.8", "79.3", "", "", "", "", "79.8"]} -{"pcdb_id": 9553, "brand_name": "Sime", "model_name": "Format 110 C LPG", "model_qualifier": "", "winter_efficiency_pct": 81.1, "summer_efficiency_pct": 71.0, "comparative_hot_water_efficiency_pct": 50.0, "output_kw_max": 31.6, "final_year_of_manufacture": 2018, "raw": ["009553", "000213", "0", "2018/Feb/26 17:01", "Fonderie Sime S.p.A.", "Sime", "Format 110 C LPG", "", "", "2003", "2018", "2", "2", "1", "2", "0", "", "", "1", "2", "2", "31.6", "31.6", "", "", "81.1", "71.0", "", "50.0", "", "2", "1", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "83.6", "81.0", "", "", "", "", "81.5"]} -{"pcdb_id": 9554, "brand_name": "Ravenheat", "model_name": "Little Star LS 100", "model_qualifier": "", "winter_efficiency_pct": 80.5, "summer_efficiency_pct": 70.4, "comparative_hot_water_efficiency_pct": 49.5, "output_kw_max": 29.0, "final_year_of_manufacture": null, "raw": ["009554", "000026", "0", "2006/Jan/17 12:31", "Ravenheat", "Ravenheat", "Little Star LS 100", "", "", "2003", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "29.0", "29.0", "", "", "80.5", "70.4", "", "49.5", "", "2", "", "", "104", "1", "2", "150", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "83.3", "80.5", "", "", "", "", "81.1"]} -{"pcdb_id": 9555, "brand_name": "Ravenheat", "model_name": "Little Star LS 100 T", "model_qualifier": "", "winter_efficiency_pct": 80.5, "summer_efficiency_pct": 70.4, "comparative_hot_water_efficiency_pct": 49.5, "output_kw_max": 29.0, "final_year_of_manufacture": null, "raw": ["009555", "000026", "0", "2006/Jan/17 12:31", "Ravenheat", "Ravenheat", "Little Star LS 100 T", "", "", "2003", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "29.0", "29.0", "", "", "80.5", "70.4", "", "49.5", "", "2", "", "", "104", "1", "2", "150", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "83.3", "80.5", "", "", "", "", "81.1"]} -{"pcdb_id": 9556, "brand_name": "Ravenheat", "model_name": "Little Star LS 100", "model_qualifier": "", "winter_efficiency_pct": 82.3, "summer_efficiency_pct": 72.2, "comparative_hot_water_efficiency_pct": 50.8, "output_kw_max": 29.0, "final_year_of_manufacture": null, "raw": ["009556", "000026", "0", "2006/Jan/17 12:31", "Ravenheat", "Ravenheat", "Little Star LS 100", "", "", "2003", "current", "2", "2", "1", "2", "0", "", "", "1", "2", "2", "29.0", "29.0", "", "", "82.3", "72.2", "", "50.8", "", "2", "0", "", "104", "1", "2", "150", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "85.1", "82.3", "", "", "", "", "82.9"]} -{"pcdb_id": 9557, "brand_name": "Ravenheat", "model_name": "Little Star LS 100 T", "model_qualifier": "", "winter_efficiency_pct": 82.3, "summer_efficiency_pct": 72.2, "comparative_hot_water_efficiency_pct": 50.8, "output_kw_max": 29.0, "final_year_of_manufacture": null, "raw": ["009557", "000026", "0", "2006/Jan/17 12:31", "Ravenheat", "Ravenheat", "Little Star LS 100 T", "", "", "2003", "current", "2", "2", "1", "2", "0", "", "", "1", "2", "2", "29.0", "29.0", "", "", "82.3", "72.2", "", "50.8", "", "2", "0", "", "104", "1", "2", "150", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "85.1", "82.3", "", "", "", "", "82.9"]} -{"pcdb_id": 9558, "brand_name": "Boulter", "model_name": "Pathfinder", "model_qualifier": "C2/6A (Gas Oil)", "winter_efficiency_pct": 85.3, "summer_efficiency_pct": 73.6, "comparative_hot_water_efficiency_pct": 53.8, "output_kw_max": 37.2, "final_year_of_manufacture": 2005, "raw": ["009558", "000041", "0", "2012/Mar/27 10:12", "Boulter Buderus", "Boulter", "Pathfinder", "C2/6A (Gas Oil)", "", "2003", "2005", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "37.2", "37.2", "", "", "85.3", "73.6", "", "53.8", "", "2", "", "", "201", "1", "1", "150", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "84.9", "85.7", "", "", "", "", "85.6"]} -{"pcdb_id": 9559, "brand_name": "Boulter", "model_name": "Pathfinder", "model_qualifier": "C2/7A (Gas Oil)", "winter_efficiency_pct": 85.4, "summer_efficiency_pct": 73.7, "comparative_hot_water_efficiency_pct": 53.8, "output_kw_max": 44.9, "final_year_of_manufacture": 2005, "raw": ["009559", "000041", "0", "2012/Mar/27 10:12", "Boulter Buderus", "Boulter", "Pathfinder", "C2/7A (Gas Oil)", "", "2003", "2005", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "44.9", "44.9", "", "", "85.4", "73.7", "", "53.8", "", "2", "", "", "201", "1", "1", "150", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.0", "85.8", "", "", "", "", "85.7"]} -{"pcdb_id": 9560, "brand_name": "Boulter", "model_name": "Pathfinder", "model_qualifier": "C2/8A (Gas Oil)", "winter_efficiency_pct": 85.5, "summer_efficiency_pct": 73.8, "comparative_hot_water_efficiency_pct": 53.9, "output_kw_max": 52.7, "final_year_of_manufacture": 2005, "raw": ["009560", "000041", "0", "2012/Mar/27 10:12", "Boulter Buderus", "Boulter", "Pathfinder", "C2/8A (Gas Oil)", "", "2003", "2005", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "52.7", "52.7", "", "", "85.5", "73.8", "", "53.9", "", "2", "", "", "201", "1", "1", "150", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.1", "85.8", "", "", "", "", "85.7"]} -{"pcdb_id": 9561, "brand_name": "Boulter", "model_name": "Pathfinder", "model_qualifier": "C2/9A (Gas Oil)", "winter_efficiency_pct": 85.7, "summer_efficiency_pct": 74.0, "comparative_hot_water_efficiency_pct": 54.1, "output_kw_max": 57.1, "final_year_of_manufacture": 2005, "raw": ["009561", "000041", "0", "2012/Mar/27 10:12", "Boulter Buderus", "Boulter", "Pathfinder", "C2/9A (Gas Oil)", "", "2003", "2005", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "57.1", "57.1", "", "", "85.7", "74.0", "", "54.1", "", "2", "", "", "201", "1", "1", "150", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.3", "86.2", "", "", "", "", "86.0"]} -{"pcdb_id": 9562, "brand_name": "Boulter", "model_name": "Pathfinder", "model_qualifier": "C2/10A (Gas Oil)", "winter_efficiency_pct": 86.0, "summer_efficiency_pct": 74.3, "comparative_hot_water_efficiency_pct": 54.3, "output_kw_max": 62.2, "final_year_of_manufacture": 2005, "raw": ["009562", "000041", "0", "2012/Mar/27 10:12", "Boulter Buderus", "Boulter", "Pathfinder", "C2/10A (Gas Oil)", "", "2003", "2005", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "62.2", "62.2", "", "", "86.0", "74.3", "", "54.3", "", "2", "", "", "201", "1", "1", "150", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.5", "86.5", "", "", "", "", "86.3"]} -{"pcdb_id": 9563, "brand_name": "Boulter", "model_name": "Pathfinder", "model_qualifier": "C2/6A (Kerosene)", "winter_efficiency_pct": 85.7, "summer_efficiency_pct": 74.0, "comparative_hot_water_efficiency_pct": 54.0, "output_kw_max": 37.4, "final_year_of_manufacture": 2005, "raw": ["009563", "000041", "0", "2012/Mar/27 10:12", "Boulter Buderus", "Boulter", "Pathfinder", "C2/6A (Kerosene)", "", "2003", "2005", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "37.4", "37.4", "", "", "85.7", "74.0", "", "54.0", "", "2", "", "", "201", "1", "1", "150", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.5", "85.9", "", "", "", "", "85.8"]} -{"pcdb_id": 9564, "brand_name": "Boulter", "model_name": "Pathfinder", "model_qualifier": "C2/7A (Kerosene)", "winter_efficiency_pct": 85.6, "summer_efficiency_pct": 73.9, "comparative_hot_water_efficiency_pct": 54.0, "output_kw_max": 44.9, "final_year_of_manufacture": 2005, "raw": ["009564", "000041", "0", "2012/Mar/27 10:12", "Boulter Buderus", "Boulter", "Pathfinder", "C2/7A (Kerosene)", "", "2003", "2005", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "44.9", "44.9", "", "", "85.6", "73.9", "", "54.0", "", "2", "", "", "201", "1", "1", "150", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.3", "85.9", "", "", "", "", "85.8"]} -{"pcdb_id": 9565, "brand_name": "Boulter", "model_name": "Pathfinder", "model_qualifier": "C2/8A (Kerosene)", "winter_efficiency_pct": 85.6, "summer_efficiency_pct": 73.9, "comparative_hot_water_efficiency_pct": 54.0, "output_kw_max": 52.7, "final_year_of_manufacture": 2005, "raw": ["009565", "000041", "0", "2012/Mar/27 10:12", "Boulter Buderus", "Boulter", "Pathfinder", "C2/8A (Kerosene)", "", "2003", "2005", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "52.7", "52.7", "", "", "85.6", "73.9", "", "54.0", "", "2", "", "", "201", "1", "1", "150", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.3", "85.9", "", "", "", "", "85.8"]} -{"pcdb_id": 9566, "brand_name": "Boulter", "model_name": "Pathfinder", "model_qualifier": "C2/9A (Kerosene)", "winter_efficiency_pct": 85.7, "summer_efficiency_pct": 74.0, "comparative_hot_water_efficiency_pct": 54.0, "output_kw_max": 57.1, "final_year_of_manufacture": 2005, "raw": ["009566", "000041", "0", "2012/Mar/27 10:12", "Boulter Buderus", "Boulter", "Pathfinder", "C2/9A (Kerosene)", "", "2003", "2005", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "57.1", "57.1", "", "", "85.7", "74.0", "", "54.0", "", "2", "", "", "201", "1", "1", "150", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.3", "86.1", "", "", "", "", "86.0"]} -{"pcdb_id": 9567, "brand_name": "Boulter", "model_name": "Pathfinder", "model_qualifier": "C2/10A (Kerosene)", "winter_efficiency_pct": 85.8, "summer_efficiency_pct": 74.1, "comparative_hot_water_efficiency_pct": 54.1, "output_kw_max": 62.2, "final_year_of_manufacture": 2005, "raw": ["009567", "000041", "0", "2012/Mar/27 10:12", "Boulter Buderus", "Boulter", "Pathfinder", "C2/10A (Kerosene)", "", "2003", "2005", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "62.2", "62.2", "", "", "85.8", "74.1", "", "54.1", "", "2", "", "", "201", "1", "1", "150", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.3", "86.3", "", "", "", "", "86.1"]} -{"pcdb_id": 9568, "brand_name": "GAH Heating Products", "model_name": "Combistream", "model_qualifier": "BFC 40/60", "winter_efficiency_pct": 84.8, "summer_efficiency_pct": 76.7, "comparative_hot_water_efficiency_pct": 46.2, "output_kw_max": 18.2, "final_year_of_manufacture": null, "raw": ["009568", "000051", "0", "2024/Jan/31 10:17", "GAH Heating Products", "GAH Heating Products", "Combistream", "BFC 40/60", "", "2003", "current", "4", "1", "1", "2", "0", "", "", "1", "2", "2", "11.7", "18.2", "", "", "84.8", "76.7", "", "46.2", "", "2", "", "", "203", "1", "1", "1200", "0", "2", "", "0", "60", "0", "25", "1", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "88.2", "88.3", "", "", "", "", "88.2"]} -{"pcdb_id": 9569, "brand_name": "Worcester", "model_name": "24i Junior", "model_qualifier": "", "winter_efficiency_pct": 78.9, "summer_efficiency_pct": 68.8, "comparative_hot_water_efficiency_pct": 48.4, "output_kw_max": 23.5, "final_year_of_manufacture": 2005, "raw": ["009569", "000035", "0", "2020/Sep/04 08:05", "Worcester Heat Systems", "Worcester", "24i Junior", "", "GC no 47 311 69", "2003", "2005", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "23.5", "23.5", "", "", "78.9", "68.8", "", "48.4", "", "2", "", "", "104", "1", "2", "152", "8", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.6", "78.6", "", "", "", "", "79.1"]} -{"pcdb_id": 9570, "brand_name": "Worcester", "model_name": "24i Junior", "model_qualifier": "", "winter_efficiency_pct": 80.9, "summer_efficiency_pct": 70.8, "comparative_hot_water_efficiency_pct": 49.8, "output_kw_max": 23.5, "final_year_of_manufacture": 2005, "raw": ["009570", "000035", "0", "2020/Sep/04 08:05", "Worcester Heat Systems", "Worcester", "24i Junior", "", "GC No 47 311 71", "2003", "2005", "2", "2", "1", "2", "0", "", "", "1", "2", "2", "23.5", "23.5", "", "", "80.9", "70.8", "", "49.8", "", "2", "0", "", "104", "1", "2", "150", "8", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "85.4", "79.5", "", "", "", "", "80.6"]} -{"pcdb_id": 9571, "brand_name": "Worcester", "model_name": "28i Junior", "model_qualifier": "", "winter_efficiency_pct": 79.8, "summer_efficiency_pct": 69.7, "comparative_hot_water_efficiency_pct": 49.0, "output_kw_max": 27.5, "final_year_of_manufacture": 2005, "raw": ["009571", "000035", "0", "2020/Sep/04 08:05", "Worcester Heat Systems", "Worcester", "28i Junior", "", "GC No 47 311 70", "2003", "2005", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "27.5", "27.5", "", "", "79.8", "69.7", "", "49.0", "", "2", "", "", "104", "1", "2", "152", "8", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.3", "79.7", "", "", "", "", "80.2"]} -{"pcdb_id": 9572, "brand_name": "Worcester", "model_name": "28i Junior", "model_qualifier": "", "winter_efficiency_pct": 82.6, "summer_efficiency_pct": 72.5, "comparative_hot_water_efficiency_pct": 51.0, "output_kw_max": 27.5, "final_year_of_manufacture": 2005, "raw": ["009572", "000035", "0", "2020/Sep/04 08:05", "Worcester Heat Systems", "Worcester", "28i Junior", "", "GC No 47 311 72", "2003", "2005", "2", "2", "1", "2", "0", "", "", "1", "2", "2", "27.5", "27.5", "", "", "82.6", "72.5", "", "51.0", "", "2", "0", "", "104", "1", "2", "152", "8", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "85.2", "82.9", "", "", "", "", "83.3"]} -{"pcdb_id": 9573, "brand_name": "Sime", "model_name": "Planet Dewy 90 A", "model_qualifier": "", "winter_efficiency_pct": 89.3, "summer_efficiency_pct": 80.7, "comparative_hot_water_efficiency_pct": 56.7, "output_kw_max": 24.5, "final_year_of_manufacture": 2018, "raw": ["009573", "000213", "0", "2018/Mar/05 14:31", "Fonderie Sime S.p.A.", "Sime", "Planet Dewy 90 A", "", "", "2003", "2018", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.5", "24.5", "", "", "89.3", "80.7", "", "56.7", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.1", "100.0", "", "", "", "", "97.8"]} -{"pcdb_id": 9574, "brand_name": "Sime", "model_name": "Planet Dewy 90 A (LPG)", "model_qualifier": "", "winter_efficiency_pct": 90.3, "summer_efficiency_pct": 81.7, "comparative_hot_water_efficiency_pct": 57.5, "output_kw_max": 24.5, "final_year_of_manufacture": 2018, "raw": ["009574", "000213", "0", "2018/Mar/05 14:31", "Fonderie Sime S.p.A.", "Sime", "Planet Dewy 90 A (LPG)", "", "", "2003", "2018", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24.5", "24.5", "", "", "90.3", "81.7", "", "57.5", "", "2", "1", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.1", "102.2", "", "", "", "", "99.9"]} -{"pcdb_id": 9575, "brand_name": "Sime", "model_name": "Planet Dewy 110 A", "model_qualifier": "", "winter_efficiency_pct": 89.3, "summer_efficiency_pct": 80.7, "comparative_hot_water_efficiency_pct": 56.8, "output_kw_max": 29.4, "final_year_of_manufacture": 2018, "raw": ["009575", "000213", "0", "2018/Mar/05 14:28", "Fonderie Sime S.p.A.", "Sime", "Planet Dewy 110 A", "", "", "2003", "2018", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "29.4", "29.4", "", "", "89.3", "80.7", "", "56.8", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "100.0", "", "", "", "", "97.8"]} -{"pcdb_id": 9576, "brand_name": "Sime", "model_name": "Planet Dewy 110 A (LPG)", "model_qualifier": "", "winter_efficiency_pct": 90.3, "summer_efficiency_pct": 81.7, "comparative_hot_water_efficiency_pct": 57.5, "output_kw_max": 29.4, "final_year_of_manufacture": 2018, "raw": ["009576", "000213", "0", "2018/Mar/05 14:28", "Fonderie Sime S.p.A.", "Sime", "Planet Dewy 110 A (LPG)", "", "", "2003", "2018", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "29.4", "29.4", "", "", "90.3", "81.7", "", "57.5", "", "2", "1", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.3", "102.2", "", "", "", "", "100.0"]} -{"pcdb_id": 9577, "brand_name": "Sime", "model_name": "Planet Dewy 110 T A", "model_qualifier": "", "winter_efficiency_pct": 89.3, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 58.7, "output_kw_max": 29.4, "final_year_of_manufacture": 2018, "raw": ["009577", "000213", "0", "2018/Mar/05 14:29", "Fonderie Sime S.p.A.", "Sime", "Planet Dewy 110 T A", "", "", "2003", "2018", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "29.4", "29.4", "", "", "89.3", "80.3", "", "58.7", "", "2", "", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "100.0", "", "", "", "", "97.8"]} -{"pcdb_id": 9578, "brand_name": "Sime", "model_name": "Planet Dewy 110 T A (LPG)", "model_qualifier": "", "winter_efficiency_pct": 90.3, "summer_efficiency_pct": 81.3, "comparative_hot_water_efficiency_pct": 59.4, "output_kw_max": 29.4, "final_year_of_manufacture": 2018, "raw": ["009578", "000213", "0", "2018/Mar/05 14:29", "Fonderie Sime S.p.A.", "Sime", "Planet Dewy 110 T A (LPG)", "", "", "2003", "2018", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "29.4", "29.4", "", "", "90.3", "81.3", "", "59.4", "", "2", "1", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.3", "102.2", "", "", "", "", "100.0"]} -{"pcdb_id": 9579, "brand_name": "Chaffoteaux et Maury", "model_name": "Centora Green System 24", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 24.0, "final_year_of_manufacture": 2007, "raw": ["009579", "000010", "0", "2012/Mar/27 10:12", "Chaffoteaux et Maury", "Chaffoteaux et Maury", "Centora Green System 24", "", "GC No. 41-980-12", "2002", "2007", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24", "24", "", "", "88.3", "79.3", "", "57.9", "", "2", "", "", "102", "1", "2", "150", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.1", "97.5", "", "", "", "", "95.7"]} -{"pcdb_id": 9580, "brand_name": "Chaffoteaux et Maury", "model_name": "Centora Green 24", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 56.0, "output_kw_max": 24.0, "final_year_of_manufacture": 2007, "raw": ["009580", "000010", "0", "2007/Jun/18 09:13", "Chaffoteaux et Maury", "Chaffoteaux et Maury", "Centora Green 24", "", "GC No. 47-980-21", "2002", "2007", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "88.3", "79.7", "", "56.0", "", "2", "", "", "104", "1", "2", "150", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.1", "97.5", "", "", "", "", "95.7"]} -{"pcdb_id": 9581, "brand_name": "Chaffoteaux et Maury", "model_name": "Calydra Green 24", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 56.0, "output_kw_max": 24.0, "final_year_of_manufacture": 2007, "raw": ["009581", "000010", "0", "2007/Jun/18 09:13", "Chaffoteaux et Maury", "Chaffoteaux et Maury", "Calydra Green 24", "", "GC No. 47-980-25", "2002", "2007", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "88.3", "79.7", "", "56.0", "", "2", "", "", "104", "1", "2", "150", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.1", "97.5", "", "", "", "", "95.7"]} -{"pcdb_id": 9582, "brand_name": "Glow-worm", "model_name": "38cxi", "model_qualifier": "", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 55.8, "output_kw_max": 30.0, "final_year_of_manufacture": null, "raw": ["009582", "000207", "0", "2006/Jan/17 12:31", "Hepworth Heating", "Glow-worm", "38cxi", "", "GC 47-047-27", "2002", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "30.0", "30.0", "", "", "87.9", "79.3", "", "55.8", "", "2", "", "", "104", "1", "2", "180", "15", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.7", "96.3", "", "", "", "", "94.9"]} -{"pcdb_id": 9583, "brand_name": "Boulter", "model_name": "Buderus", "model_qualifier": "600/11S", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 11.0, "final_year_of_manufacture": 2007, "raw": ["009583", "000041", "0", "2012/Mar/27 10:12", "Boulter Buderus", "Boulter", "Buderus", "600/11S", "7105030", "2000", "2007", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "11.0", "11.0", "", "", "88.6", "79.6", "", "58.2", "", "2", "", "", "102", "1", "2", "115", "6.5", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.1", "98.3", "", "", "", "", "96.4"]} -{"pcdb_id": 9584, "brand_name": "Boulter", "model_name": "Buderus", "model_qualifier": "600/19S", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 19.0, "final_year_of_manufacture": 2007, "raw": ["009584", "000041", "0", "2012/Mar/27 10:12", "Boulter Buderus", "Boulter", "Buderus", "600/19S", "7105040", "2000", "2007", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "19.0", "19.0", "", "", "88.6", "79.6", "", "58.1", "", "2", "", "", "102", "1", "2", "115", "6.5", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.1", "98.2", "", "", "", "", "96.3"]} -{"pcdb_id": 9585, "brand_name": "Boulter", "model_name": "Buderus", "model_qualifier": "600/24S", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 24.0, "final_year_of_manufacture": 2007, "raw": ["009585", "000041", "0", "2012/Mar/27 10:12", "Boulter Buderus", "Boulter", "Buderus", "600/24S", "7105050", "2000", "2007", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24.0", "24.0", "", "", "88.5", "79.5", "", "58.1", "", "2", "", "", "102", "1", "2", "115", "6.5", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "98.0", "", "", "", "", "96.1"]} -{"pcdb_id": 9586, "brand_name": "Boulter", "model_name": "Buderus", "model_qualifier": "600/24C", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 56.2, "output_kw_max": 24.0, "final_year_of_manufacture": 2007, "raw": ["009586", "000041", "0", "2008/Aug/18 09:29", "Boulter Buderus", "Boulter", "Buderus", "600/24C", "7105060", "2000", "2007", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.0", "24.0", "", "", "88.5", "79.9", "", "56.2", "", "2", "", "", "104", "1", "2", "115", "8", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "98.0", "", "", "", "", "96.1"]} -{"pcdb_id": 9587, "brand_name": "Boulter", "model_name": "Buderus", "model_qualifier": "800/24", "winter_efficiency_pct": 87.8, "summer_efficiency_pct": 78.8, "comparative_hot_water_efficiency_pct": 57.6, "output_kw_max": 23.4, "final_year_of_manufacture": null, "raw": ["009587", "000041", "0", "2012/Mar/27 10:12", "Boulter Buderus", "Boulter", "Buderus", "800/24", "87470124", "1999", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "23.40", "23.40", "", "", "87.8", "78.8", "", "57.6", "", "2", "", "", "102", "1", "2", "120", "8", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.7", "96.4", "", "", "", "", "94.7"]} -{"pcdb_id": 9588, "brand_name": "Boulter", "model_name": "Buderus", "model_qualifier": "800-24T25/V", "winter_efficiency_pct": 87.8, "summer_efficiency_pct": 80.6, "comparative_hot_water_efficiency_pct": 50.6, "output_kw_max": 23.4, "final_year_of_manufacture": 2004, "raw": ["009588", "000041", "0", "2024/Jan/31 10:17", "Boulter Buderus", "Boulter", "Buderus", "800-24T25/V", "87470128", "1999", "2004", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "23.40", "23.40", "", "", "87.8", "80.6", "", "50.6", "", "2", "", "", "106", "1", "2", "120", "8", "2", "2", "0", "26", "0", "27", "2", "60", "25", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.7", "96.4", "", "", "", "", "94.7"]} -{"pcdb_id": 9589, "brand_name": "Boulter", "model_name": "Buderus", "model_qualifier": "800-24T25/H", "winter_efficiency_pct": 87.8, "summer_efficiency_pct": 80.6, "comparative_hot_water_efficiency_pct": 50.6, "output_kw_max": 23.4, "final_year_of_manufacture": 2004, "raw": ["009589", "000041", "0", "2024/Jan/31 10:17", "Boulter Buderus", "Boulter", "Buderus", "800-24T25/H", "87470132", "1999", "2004", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "23.4", "23.4", "", "", "87.8", "80.6", "", "50.6", "", "2", "", "", "106", "1", "2", "120", "8", "2", "2", "0", "26", "0", "27", "2", "60", "25", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.7", "96.4", "", "", "", "", "94.7"]} -{"pcdb_id": 9590, "brand_name": "Boulter", "model_name": "Buderus", "model_qualifier": "800/29", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 78.9, "comparative_hot_water_efficiency_pct": 57.6, "output_kw_max": 29.9, "final_year_of_manufacture": null, "raw": ["009590", "000041", "0", "2012/Mar/27 10:12", "Boulter Buderus", "Boulter", "Buderus", "800/29", "87470126", "1999", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "29.9", "29.9", "", "", "87.9", "78.9", "", "57.6", "", "2", "", "", "102", "1", "2", "130", "8", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "96.5", "", "", "", "", "94.9"]} -{"pcdb_id": 9591, "brand_name": "Boulter", "model_name": "Buderus", "model_qualifier": "800-29T25/V", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 80.6, "comparative_hot_water_efficiency_pct": 50.7, "output_kw_max": 29.9, "final_year_of_manufacture": 2004, "raw": ["009591", "000041", "0", "2024/Jan/31 10:17", "Boulter Buderus", "Boulter", "Buderus", "800-29T25/V", "87470130", "1999", "2004", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "29.90", "29.90", "", "", "87.9", "80.6", "", "50.7", "", "2", "", "", "106", "1", "2", "130", "8", "2", "2", "0", "26", "0", "27", "2", "60", "25", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "96.5", "", "", "", "", "94.9"]} -{"pcdb_id": 9592, "brand_name": "Boulter", "model_name": "Buderus", "model_qualifier": "800-29T25/H", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 80.6, "comparative_hot_water_efficiency_pct": 51.5, "output_kw_max": 29.9, "final_year_of_manufacture": 2004, "raw": ["009592", "000041", "0", "2024/Jan/31 10:17", "Boulter Buderus", "Boulter", "Buderus", "800-29T25/H", "87470134", "1999", "2004", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "29.90", "29.90", "", "", "87.9", "80.6", "", "51.5", "", "2", "", "", "106", "1", "2", "130", "8", "2", "2", "0", "26", "0", "30", "2", "60", "25", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "96.5", "", "", "", "", "94.9"]} -{"pcdb_id": 9593, "brand_name": "Boulter", "model_name": "Buderus", "model_qualifier": "800/43", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 78.9, "comparative_hot_water_efficiency_pct": 57.6, "output_kw_max": 42.9, "final_year_of_manufacture": null, "raw": ["009593", "000041", "0", "2012/Mar/27 10:12", "Boulter Buderus", "Boulter", "Buderus", "800/43", "87470110", "1999", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "42.9", "42.9", "", "", "87.9", "78.9", "", "57.6", "", "2", "", "", "102", "1", "2", "180", "8", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.1", "96.4", "", "", "", "", "94.8"]} -{"pcdb_id": 9594, "brand_name": "Boulter", "model_name": "Buderus", "model_qualifier": "800/60", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 78.9, "comparative_hot_water_efficiency_pct": 57.6, "output_kw_max": 60.0, "final_year_of_manufacture": 2008, "raw": ["009594", "000041", "0", "2012/Mar/27 10:12", "Boulter Buderus", "Boulter", "Buderus", "800/60", "87470112", "1999", "2008", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "60", "60", "", "", "87.9", "78.9", "", "57.6", "", "2", "", "", "102", "1", "2", "200", "8", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "96.5", "", "", "", "", "94.9"]} -{"pcdb_id": 9595, "brand_name": "Itho Images bv", "model_name": "Ethos", "model_qualifier": "28", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 56.4, "output_kw_max": 28.0, "final_year_of_manufacture": null, "raw": ["009595", "000226", "0", "2013/Jun/25 14:36", "Itho Images bv", "Itho Images bv", "Ethos", "28", "", "2003", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28", "28", "", "", "88.8", "80.2", "", "56.4", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "98.7", "", "", "", "", "96.8"]} -{"pcdb_id": 9596, "brand_name": "Itho Images bv", "model_name": "Ethos", "model_qualifier": "36", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 56.4, "output_kw_max": 36.0, "final_year_of_manufacture": null, "raw": ["009596", "000226", "0", "2013/Jun/25 14:36", "Itho Images bv", "Itho Images bv", "Ethos", "36", "", "2003", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "36", "36", "", "", "88.8", "80.2", "", "56.4", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "98.7", "", "", "", "", "96.8"]} -{"pcdb_id": 9597, "brand_name": "Itho Images bv", "model_name": "Ethos", "model_qualifier": "46", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 56.4, "output_kw_max": 46.0, "final_year_of_manufacture": null, "raw": ["009597", "000226", "0", "2013/Jun/25 14:36", "Itho Images bv", "Itho Images bv", "Ethos", "46", "", "2003", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "46", "46", "", "", "88.8", "80.2", "", "56.4", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "98.7", "", "", "", "", "96.8"]} -{"pcdb_id": 9598, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "ZWBR 7-30 HE Plus", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 55.9, "output_kw_max": 29.5, "final_year_of_manufacture": 2003, "raw": ["009598", "000035", "0", "2003/Jun/17 12:54", "Worcester Heat Systems", "Worcester", "Greenstar", "ZWBR 7-30 HE Plus", "47 311 75", "2003", "2003", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "29.5", "29.5", "", "", "88.1", "79.5", "", "55.9", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.9", "96.8", "", "", "", "", "95.3"]} -{"pcdb_id": 9599, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "ZB 7-28 HE", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 27.7, "final_year_of_manufacture": 2003, "raw": ["009599", "000035", "0", "2012/Mar/27 10:12", "Worcester Heat Systems", "Worcester", "Greenstar", "ZB 7-28 HE", "41 311 58", "2003", "2003", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "27.7", "27.7", "", "", "88.1", "79.1", "", "57.8", "", "2", "", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.9", "96.8", "", "", "", "", "95.3"]} -{"pcdb_id": 9600, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "ZWBR 11-35 HE Plus", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 56.5, "output_kw_max": 35.5, "final_year_of_manufacture": 2003, "raw": ["009600", "000035", "0", "2003/Jun/17 12:56", "Worcester Heat Systems", "Worcester", "Greenstar", "ZWBR 11-35 HE Plus", "47 311 57", "2002", "2003", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "35.5", "35.5", "", "", "88.9", "80.3", "", "56.5", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.5", "98.9", "", "", "", "", "96.9"]} -{"pcdb_id": 9601, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "ZWB 7-25 HE Combi", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 55.9, "output_kw_max": 27.5, "final_year_of_manufacture": 2003, "raw": ["009601", "000035", "0", "2003/Jun/17 12:52", "Worcester Heat Systems", "Worcester", "Greenstar", "ZWB 7-25 HE Combi", "47 311 73", "2003", "2003", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "27.5", "27.5", "", "", "88.1", "79.5", "", "55.9", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.9", "96.8", "", "", "", "", "95.3"]} -{"pcdb_id": 9602, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "ZWB 7-30 HE Combi", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 55.9, "output_kw_max": 29.5, "final_year_of_manufacture": 2003, "raw": ["009602", "000035", "0", "2003/Jun/17 12:52", "Worcester Heat Systems", "Worcester", "Greenstar", "ZWB 7-30 HE Combi", "47 311 74", "2003", "2003", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "29.5", "29.5", "", "", "88.1", "79.5", "", "55.9", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.9", "96.8", "", "", "", "", "95.3"]} -{"pcdb_id": 9603, "brand_name": "Firebird", "model_name": "Combi", "model_qualifier": "50-70", "winter_efficiency_pct": 83.3, "summer_efficiency_pct": 75.2, "comparative_hot_water_efficiency_pct": 41.2, "output_kw_max": 20.52, "final_year_of_manufacture": 2013, "raw": ["009603", "000047", "0", "2024/Jan/31 10:17", "Firebird Boilers", "Firebird", "Combi", "50-70", "", "2003", "2013", "4", "1", "1", "2", "0", "", "", "1", "2", "1", "14.65", "20.52", "", "", "83.3", "75.2", "", "41.2", "", "2", "", "", "203", "1", "1", "138", "0", "1", "1", "0", "40", "0", "25", "3", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.1", "85.4", "", "", "", "", "85.3"]} -{"pcdb_id": 9604, "brand_name": "Firebird", "model_name": "Combipac", "model_qualifier": "50-70", "winter_efficiency_pct": 83.3, "summer_efficiency_pct": 75.2, "comparative_hot_water_efficiency_pct": 41.2, "output_kw_max": 20.52, "final_year_of_manufacture": 2013, "raw": ["009604", "000047", "0", "2024/Jan/31 10:17", "Firebird Boilers", "Firebird", "Combipac", "50-70", "", "2003", "2013", "4", "1", "2", "2", "0", "", "", "1", "1", "1", "14.65", "20.52", "", "", "83.3", "75.2", "", "41.2", "", "2", "", "", "203", "1", "1", "138", "0", "1", "1", "0", "40", "0", "25", "3", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.1", "85.4", "", "", "", "", "85.3"]} -{"pcdb_id": 9605, "brand_name": "Firebird", "model_name": "Combi", "model_qualifier": "70-90", "winter_efficiency_pct": 83.3, "summer_efficiency_pct": 75.2, "comparative_hot_water_efficiency_pct": 41.2, "output_kw_max": 26.38, "final_year_of_manufacture": 2010, "raw": ["009605", "000047", "0", "2024/Jan/31 10:17", "Firebird Boilers", "Firebird", "Combi", "70-90", "", "2003", "2010", "4", "1", "1", "2", "0", "", "", "1", "2", "1", "20.52", "26.38", "", "", "83.3", "75.2", "", "41.2", "", "2", "", "", "203", "1", "1", "138", "0", "1", "1", "0", "40", "0", "25", "3", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "84.7", "85.7", "", "", "", "", "85.5"]} -{"pcdb_id": 9606, "brand_name": "Firebird", "model_name": "Combipac", "model_qualifier": "70-90", "winter_efficiency_pct": 83.3, "summer_efficiency_pct": 75.2, "comparative_hot_water_efficiency_pct": 41.2, "output_kw_max": 26.38, "final_year_of_manufacture": 2013, "raw": ["009606", "000047", "0", "2024/Jan/31 10:17", "Firebird Boilers", "Firebird", "Combipac", "70-90", "", "2003", "2013", "4", "1", "2", "2", "0", "", "", "1", "1", "1", "20.52", "26.38", "", "", "83.3", "75.2", "", "41.2", "", "2", "", "", "203", "1", "1", "138", "0", "1", "1", "0", "40", "0", "25", "3", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "84.7", "85.7", "", "", "", "", "85.5"]} -{"pcdb_id": 9607, "brand_name": "Firebird", "model_name": "Combi", "model_qualifier": "90-120", "winter_efficiency_pct": 84.5, "summer_efficiency_pct": 76.4, "comparative_hot_water_efficiency_pct": 41.6, "output_kw_max": 35.17, "final_year_of_manufacture": 2013, "raw": ["009607", "000047", "0", "2024/Jan/31 10:17", "Firebird Boilers", "Firebird", "Combi", "90-120", "", "2003", "2013", "4", "1", "1", "2", "0", "", "", "1", "2", "1", "26.38", "35.17", "", "", "84.5", "76.4", "", "41.6", "", "2", "", "", "203", "1", "1", "138", "0", "1", "1", "0", "44", "0", "25", "3", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.4", "86.7", "", "", "", "", "86.6"]} -{"pcdb_id": 9608, "brand_name": "Firebird", "model_name": "Combipac", "model_qualifier": "90-120", "winter_efficiency_pct": 84.5, "summer_efficiency_pct": 76.4, "comparative_hot_water_efficiency_pct": 41.6, "output_kw_max": 35.17, "final_year_of_manufacture": 2013, "raw": ["009608", "000047", "0", "2024/Jan/31 10:17", "Firebird Boilers", "Firebird", "Combipac", "90-120", "", "2003", "2013", "4", "1", "2", "2", "0", "", "", "1", "1", "1", "26.38", "35.17", "", "", "84.5", "76.4", "", "41.6", "", "2", "", "", "203", "1", "1", "138", "0", "1", "1", "0", "44", "0", "25", "3", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.4", "86.7", "", "", "", "", "86.6"]} -{"pcdb_id": 9609, "brand_name": "Radiant", "model_name": "RK 25", "model_qualifier": "", "winter_efficiency_pct": 87.7, "summer_efficiency_pct": 78.7, "comparative_hot_water_efficiency_pct": 57.5, "output_kw_max": 26.67, "final_year_of_manufacture": null, "raw": ["009609", "000088", "0", "2012/Mar/27 10:12", "Radiant Bruciatori SpA", "Radiant", "RK 25", "", "", "2002", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "26.67", "26.67", "", "", "87.7", "78.7", "", "57.5", "", "2", "", "", "102", "1", "2", "170", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.7", "95.8", "", "", "", "", "94.4"]} -{"pcdb_id": 9610, "brand_name": "Radiant", "model_name": "RKR 25", "model_qualifier": "", "winter_efficiency_pct": 87.7, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 55.6, "output_kw_max": 26.67, "final_year_of_manufacture": null, "raw": ["009610", "000088", "0", "2006/Jan/17 12:31", "Radiant Bruciatori SpA", "Radiant", "RKR 25", "", "", "2002", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "26.67", "26.67", "", "", "87.7", "79.1", "", "55.6", "", "2", "", "", "104", "1", "2", "180", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.7", "95.8", "", "", "", "", "94.4"]} -{"pcdb_id": 9611, "brand_name": "Radiant", "model_name": "RKA 100", "model_qualifier": "", "winter_efficiency_pct": 87.7, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 36.6, "output_kw_max": 26.67, "final_year_of_manufacture": 2007, "raw": ["009611", "000088", "0", "2024/Jan/31 10:17", "Radiant Bruciatori SpA", "Radiant", "RKA 100", "", "", "2002", "2007", "1", "1", "1", "2", "0", "", "", "2", "2", "2", "26.67", "26.67", "", "", "87.7", "81.0", "", "36.6", "", "2", "", "", "106", "1", "2", "180", "", "2", "2", "0", "104", "0", "15", "2", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.7", "95.8", "", "", "", "", "94.4"]} -{"pcdb_id": 9612, "brand_name": "Radiant", "model_name": "RKA 25", "model_qualifier": "", "winter_efficiency_pct": 87.7, "summer_efficiency_pct": 80.6, "comparative_hot_water_efficiency_pct": 44.8, "output_kw_max": 26.67, "final_year_of_manufacture": null, "raw": ["009612", "000088", "0", "2024/Jan/31 10:17", "Radiant Bruciatori SpA", "Radiant", "RKA 25", "", "", "2002", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "26.67", "26.67", "", "", "87.7", "80.6", "", "44.8", "", "2", "", "", "106", "1", "2", "180", "", "2", "2", "0", "28.3", "0", "15", "2", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.7", "95.8", "", "", "", "", "94.4"]} -{"pcdb_id": 9613, "brand_name": "Radiant", "model_name": "RMAS 30 E", "model_qualifier": "", "winter_efficiency_pct": 81.5, "summer_efficiency_pct": 72.4, "comparative_hot_water_efficiency_pct": 40.3, "output_kw_max": 31.9, "final_year_of_manufacture": null, "raw": ["009613", "000088", "0", "2024/Jan/31 10:17", "Radiant Bruciatori SpA", "Radiant", "RMAS 30 E", "", "", "2002", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "31.90", "31.90", "", "", "81.5", "72.4", "", "40.3", "", "2", "", "", "106", "1", "2", "170", "", "2", "2", "0", "28.3", "0", "15", "2", "60", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "83.3", "81.5", "", "", "", "", "81.9"]} -{"pcdb_id": 9614, "brand_name": "Radiant", "model_name": "RS 30 E", "model_qualifier": "", "winter_efficiency_pct": 81.2, "summer_efficiency_pct": 70.5, "comparative_hot_water_efficiency_pct": 51.5, "output_kw_max": 31.9, "final_year_of_manufacture": null, "raw": ["009614", "000088", "0", "2012/Mar/27 10:12", "Radiant Bruciatori SpA", "Radiant", "RS 30 E", "", "", "2002", "current", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "31.90", "31.90", "", "", "81.2", "70.5", "", "51.5", "", "2", "", "", "102", "1", "2", "170", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "83.3", "81.5", "", "", "", "", "81.9"]} -{"pcdb_id": 9615, "brand_name": "Radiant", "model_name": "RSF 30 E", "model_qualifier": "", "winter_efficiency_pct": 81.0, "summer_efficiency_pct": 70.9, "comparative_hot_water_efficiency_pct": 49.9, "output_kw_max": 31.9, "final_year_of_manufacture": null, "raw": ["009615", "000088", "0", "2006/Jan/17 12:31", "Radiant Bruciatori SpA", "Radiant", "RSF 30 E", "", "", "2002", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "31.90", "31.90", "", "", "81.0", "70.9", "", "49.9", "", "2", "", "", "104", "1", "2", "170", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "83.3", "81.5", "", "", "", "", "81.9"]} -{"pcdb_id": 9616, "brand_name": "ATAG", "model_name": "Blauwe Engel", "model_qualifier": "SHR 15", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 14.4, "final_year_of_manufacture": 2007, "raw": ["009616", "000227", "0", "2012/Mar/27 10:12", "ATAG Verwarming Nederland BV", "ATAG", "Blauwe Engel", "SHR 15", "", "1996", "2007", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "14.4", "14.4", "", "", "88.6", "79.6", "", "58.2", "", "2", "", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.5", "98.2", "", "", "", "", "96.4"]} -{"pcdb_id": 9617, "brand_name": "ATAG", "model_name": "Blauwe Engel", "model_qualifier": "SHR 24", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 23.0, "final_year_of_manufacture": 2007, "raw": ["009617", "000227", "0", "2012/Mar/27 10:12", "ATAG Verwarming Nederland BV", "ATAG", "Blauwe Engel", "SHR 24", "", "1996", "2007", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "23.0", "23.0", "", "", "88.6", "79.6", "", "58.2", "", "2", "", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.5", "98.2", "", "", "", "", "96.4"]} -{"pcdb_id": 9618, "brand_name": "ATAG", "model_name": "Premier", "model_qualifier": "E-SHR 35", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 33.6, "final_year_of_manufacture": 2007, "raw": ["009618", "000227", "0", "2012/Mar/27 10:12", "ATAG Verwarming Nederland BV", "ATAG", "Premier", "E-SHR 35", "", "1999", "2007", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "33.6", "33.6", "", "", "88.3", "79.3", "", "57.9", "", "2", "", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.4", "97.3", "", "", "", "", "95.6"]} -{"pcdb_id": 9619, "brand_name": "ATAG", "model_name": "Blauwe Engel", "model_qualifier": "SHR 35", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 33.6, "final_year_of_manufacture": 2007, "raw": ["009619", "000227", "0", "2012/Mar/27 10:12", "ATAG Verwarming Nederland BV", "ATAG", "Blauwe Engel", "SHR 35", "", "1996", "2007", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "33.6", "33.6", "", "", "88.3", "79.3", "", "57.9", "", "2", "", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.4", "97.3", "", "", "", "", "95.6"]} -{"pcdb_id": 9620, "brand_name": "ATAG", "model_name": "Blauwe Engel", "model_qualifier": "SHR 51", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 48.7, "final_year_of_manufacture": 2003, "raw": ["009620", "000227", "0", "2012/Mar/27 10:12", "ATAG Verwarming Nederland BV", "ATAG", "Blauwe Engel", "SHR 51", "", "1996", "2003", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "48.7", "48.7", "", "", "88.5", "79.5", "", "58.0", "", "2", "", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.6", "98.1", "", "", "", "", "96.1"]} -{"pcdb_id": 9621, "brand_name": "ATAG", "model_name": "Blauwe Engel", "model_qualifier": "SHR 60", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 57.2, "final_year_of_manufacture": 2007, "raw": ["009621", "000227", "0", "2012/Mar/27 10:12", "ATAG Verwarming Nederland BV", "ATAG", "Blauwe Engel", "SHR 60", "", "1996", "2007", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "57.2", "57.2", "", "", "88.3", "79.3", "", "57.9", "", "2", "", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.1", "97.5", "", "", "", "", "95.7"]} -{"pcdb_id": 9622, "brand_name": "ATAG", "model_name": "Premier", "model_qualifier": "E-SHR 24T", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 23.0, "final_year_of_manufacture": 2007, "raw": ["009622", "000227", "0", "2012/Mar/27 10:12", "ATAG Verwarming Nederland BV", "ATAG", "Premier", "E-SHR 24T", "", "1999", "2007", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "23.0", "23.0", "", "", "88.6", "79.6", "", "58.2", "", "2", "", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.5", "98.2", "", "", "", "", "96.4"]} -{"pcdb_id": 9623, "brand_name": "ATAG", "model_name": "Premier", "model_qualifier": "E-SHR 35T", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 56.0, "output_kw_max": 33.6, "final_year_of_manufacture": 2007, "raw": ["009623", "000227", "0", "2018/Apr/25 14:41", "ATAG Verwarming Nederland BV", "ATAG", "Premier", "E-SHR 35T", "", "1999", "2007", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "33.6", "33.6", "", "", "88.3", "79.7", "", "56.0", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.4", "97.3", "", "", "", "", "95.6"]} -{"pcdb_id": 9624, "brand_name": "ATAG", "model_name": "Blauwe Engel", "model_qualifier": "SHR 35T", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 56.0, "output_kw_max": 33.6, "final_year_of_manufacture": 2007, "raw": ["009624", "000227", "0", "2007/Feb/22 09:57", "ATAG Verwarming Nederland BV", "ATAG", "Blauwe Engel", "SHR 35T", "", "1996", "2007", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "33.6", "33.6", "", "", "88.3", "79.7", "", "56.0", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.4", "97.3", "", "", "", "", "95.6"]} -{"pcdb_id": 9625, "brand_name": "ATAG", "model_name": "Blauwe Engel", "model_qualifier": "SHR 51T", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 56.2, "output_kw_max": 48.7, "final_year_of_manufacture": 2007, "raw": ["009625", "000227", "0", "2018/Apr/25 14:45", "ATAG Verwarming Nederland BV", "ATAG", "Blauwe Engel", "SHR 51T", "", "1996", "2007", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "48.7", "48.7", "", "", "88.5", "79.9", "", "56.2", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.6", "98.1", "", "", "", "", "96.1"]} -{"pcdb_id": 9626, "brand_name": "ATAG", "model_name": "Premier", "model_qualifier": "E-SHR 24", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 23.0, "final_year_of_manufacture": 2007, "raw": ["009626", "000227", "0", "2012/Mar/27 10:12", "ATAG Verwarming Nederland BV", "ATAG", "Premier", "E-SHR 24", "", "1999", "2007", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "23.0", "23.0", "", "", "88.3", "79.3", "", "57.9", "", "2", "", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.4", "97.3", "", "", "", "", "95.6"]} -{"pcdb_id": 9627, "brand_name": "ATAG", "model_name": "Blauwe Engel", "model_qualifier": "SHR 24T", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 56.3, "output_kw_max": 23.0, "final_year_of_manufacture": 2007, "raw": ["009627", "000227", "0", "2007/Feb/22 09:56", "ATAG Verwarming Nederland BV", "ATAG", "Blauwe Engel", "SHR 24T", "", "1996", "2007", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "23.0", "23.0", "", "", "88.6", "80.0", "", "56.3", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.5", "98.2", "", "", "", "", "96.4"]} -{"pcdb_id": 9628, "brand_name": "Saunier Duval", "model_name": "Envirotek F28E", "model_qualifier": "", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 56.4, "output_kw_max": 29.0, "final_year_of_manufacture": 2003, "raw": ["009628", "000206", "0", "2006/Jan/17 12:55", "Hepworth Heating", "Saunier Duval", "Envirotek F28E", "", "GC 47-920-39", "2003", "2003", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "29.0", "29.0", "", "", "88.9", "80.3", "", "56.4", "", "2", "", "", "104", "1", "2", "180", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "0", "", "0005", "", "", "", "", "", "", "", "", "88.4", "98.8", "", "", "", "", "96.9"]} -{"pcdb_id": 9629, "brand_name": "Ferroli", "model_name": "Econcept", "model_qualifier": "50A", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 45.2, "final_year_of_manufacture": 2017, "raw": ["009629", "000097", "0", "2017/Aug/07 16:56", "Ferroli SpA", "Ferroli", "Econcept", "50A", "", "2002", "2017", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "45.2", "45.2", "", "", "88.6", "79.6", "", "58.2", "", "2", "", "", "102", "1", "2", "190", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.5", "98.2", "", "", "", "", "96.4"]} -{"pcdb_id": 9630, "brand_name": "Saunier Duval", "model_name": "Envirotek F28E SB", "model_qualifier": "", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 29.0, "final_year_of_manufacture": 2003, "raw": ["009630", "000206", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Saunier Duval", "Envirotek F28E SB", "", "GC 41-920-37", "2003", "2003", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "29.0", "29.0", "", "", "88.9", "79.9", "", "58.3", "", "2", "", "", "102", "1", "2", "180", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.4", "98.8", "", "", "", "", "96.9"]} -{"pcdb_id": 9631, "brand_name": "Vaillant", "model_name": "Thermocompact", "model_qualifier": "637 E", "winter_efficiency_pct": 80.9, "summer_efficiency_pct": 70.2, "comparative_hot_water_efficiency_pct": 51.3, "output_kw_max": 36.9, "final_year_of_manufacture": 2010, "raw": ["009631", "000031", "0", "2012/Mar/27 10:12", "Vaillant", "Vaillant", "Thermocompact", "637 E", "VU GB 362/2-5", "2003", "2010", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "36.9", "36.9", "", "", "80.9", "70.2", "", "51.3", "", "2", "", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.0", "81.8", "", "", "", "", "81.8"]} -{"pcdb_id": 9632, "brand_name": "British Gas", "model_name": "RD628", "model_qualifier": "RSF", "winter_efficiency_pct": 79.3, "summer_efficiency_pct": 69.2, "comparative_hot_water_efficiency_pct": 48.6, "output_kw_max": 28.0, "final_year_of_manufacture": null, "raw": ["009632", "000035", "0", "2006/Jan/17 12:31", "Worcester Heat Systems", "British Gas", "RD628", "RSF", "47 108 14", "2003", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "28", "28", "", "", "79.3", "69.2", "", "48.6", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.3", "78.7", "", "", "", "", "79.3"]} -{"pcdb_id": 9634, "brand_name": "Coopra BV", "model_name": "Biasi Riva Condensing", "model_qualifier": "M101.31 S (P)", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 56.3, "output_kw_max": 24.5, "final_year_of_manufacture": 2002, "raw": ["009634", "000208", "0", "2008/May/22 11:19", "Coopra BV", "Coopra BV", "Biasi Riva Condensing", "M101.31 S (P)", "", "1997", "2002", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.5", "24.5", "", "", "88.7", "80.1", "", "56.3", "", "2", "", "", "104", "1", "2", "65", "10", "0", "", "", "0", "0", "0", "", "0", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.0", "98.0", "", "", "", "", "96.3"]} -{"pcdb_id": 9635, "brand_name": "Coopra BV", "model_name": "Biasi Riva Condensing", "model_qualifier": "M101.31 SR (P)", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 24.5, "final_year_of_manufacture": 2002, "raw": ["009635", "000208", "0", "2012/Mar/27 10:12", "Coopra BV", "Coopra BV", "Biasi Riva Condensing", "M101.31 SR (P)", "", "1997", "2002", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24.5", "24.5", "", "", "88.7", "79.7", "", "58.2", "", "2", "", "", "102", "1", "2", "65", "10", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.0", "98.0", "", "", "", "", "96.3"]} -{"pcdb_id": 9636, "brand_name": "Coopra BV", "model_name": "Biasi Riva Condensing", "model_qualifier": "M101.31 SRB (P)", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 24.5, "final_year_of_manufacture": 2002, "raw": ["009636", "000208", "0", "2012/Mar/27 10:12", "Coopra BV", "Coopra BV", "Biasi Riva Condensing", "M101.31 SRB (P)", "", "1997", "2002", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24.5", "24.5", "", "", "88.7", "79.7", "", "58.2", "", "2", "", "", "102", "1", "2", "65", "10", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.0", "98.0", "", "", "", "", "96.3"]} -{"pcdb_id": 9637, "brand_name": "Biasi", "model_name": "Garda", "model_qualifier": "M90F. 28SR", "winter_efficiency_pct": 81.2, "summer_efficiency_pct": 70.5, "comparative_hot_water_efficiency_pct": 51.5, "output_kw_max": 28.4, "final_year_of_manufacture": 2007, "raw": ["009637", "000208", "0", "2012/Mar/27 10:12", "Biasi SpA", "Biasi", "Garda", "M90F. 28SR", "41-970-11", "2002", "2007", "2", "2", "1", "1", "0", "", "", "1", "2", "2", "28.4", "28.4", "", "", "81.2", "70.5", "", "51.5", "", "2", "1", "", "102", "1", "2", "170", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "84.0", "80.3", "", "", "", "", "81.0"]} -{"pcdb_id": 9638, "brand_name": "Biasi", "model_name": "Garda", "model_qualifier": "M90F. 28S", "winter_efficiency_pct": 81.0, "summer_efficiency_pct": 70.9, "comparative_hot_water_efficiency_pct": 49.8, "output_kw_max": 28.4, "final_year_of_manufacture": 2007, "raw": ["009638", "000208", "0", "2008/May/22 11:38", "Biasi SpA", "Biasi", "Garda", "M90F. 28S", "47-970-20", "2002", "2007", "2", "2", "1", "2", "0", "", "", "1", "2", "2", "28.4", "28.4", "", "", "81.0", "70.9", "", "49.8", "", "2", "1", "", "104", "1", "2", "170", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "84.0", "80.3", "", "", "", "", "81.0"]} -{"pcdb_id": 9639, "brand_name": "Biasi", "model_name": "Garda", "model_qualifier": "M90F. 24SR", "winter_efficiency_pct": 81.1, "summer_efficiency_pct": 70.4, "comparative_hot_water_efficiency_pct": 51.4, "output_kw_max": 24.3, "final_year_of_manufacture": 2007, "raw": ["009639", "000208", "0", "2012/Mar/27 10:12", "Biasi SpA", "Biasi", "Garda", "M90F. 24SR", "41-970-10", "2002", "2007", "2", "2", "1", "1", "0", "", "", "1", "2", "2", "24.3", "24.3", "", "", "81.1", "70.4", "", "51.4", "", "2", "1", "", "102", "1", "2", "150", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "84.1", "80.1", "", "", "", "", "80.9"]} -{"pcdb_id": 9640, "brand_name": "Biasi", "model_name": "Garda", "model_qualifier": "M90F. 24S", "winter_efficiency_pct": 80.9, "summer_efficiency_pct": 70.8, "comparative_hot_water_efficiency_pct": 49.8, "output_kw_max": 24.3, "final_year_of_manufacture": 2007, "raw": ["009640", "000208", "0", "2008/May/22 11:39", "Biasi SpA", "Biasi", "Garda", "M90F. 24S", "47-970-19", "2002", "2007", "2", "2", "1", "2", "0", "", "", "1", "2", "2", "24.3", "24.3", "", "", "80.9", "70.8", "", "49.8", "", "2", "1", "", "104", "1", "2", "150", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "84.1", "80.1", "", "", "", "", "80.9"]} -{"pcdb_id": 9641, "brand_name": "Biasi", "model_name": "Riva Compact", "model_qualifier": "M90E. 28S", "winter_efficiency_pct": 81.0, "summer_efficiency_pct": 70.9, "comparative_hot_water_efficiency_pct": 49.8, "output_kw_max": 28.4, "final_year_of_manufacture": null, "raw": ["009641", "000208", "0", "2006/Jan/17 12:31", "Biasi SpA", "Biasi", "Riva Compact", "M90E. 28S", "47-970-18", "2002", "current", "2", "2", "1", "2", "0", "", "", "1", "2", "2", "28.4", "28.4", "", "", "81.0", "70.9", "", "49.8", "", "2", "1", "", "104", "1", "2", "170", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "84.0", "80.3", "", "", "", "", "81.0"]} -{"pcdb_id": 9642, "brand_name": "Biasi", "model_name": "Riva Compact", "model_qualifier": "M90E. 24S", "winter_efficiency_pct": 80.9, "summer_efficiency_pct": 70.8, "comparative_hot_water_efficiency_pct": 49.8, "output_kw_max": 24.3, "final_year_of_manufacture": null, "raw": ["009642", "000208", "0", "2006/Jan/17 12:31", "Biasi SpA", "Biasi", "Riva Compact", "M90E. 24S", "47-970-17", "2002", "current", "2", "2", "1", "2", "0", "", "", "1", "2", "2", "24.3", "24.3", "", "", "80.9", "70.8", "", "49.8", "", "2", "1", "", "104", "1", "2", "150", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "84.1", "80.1", "", "", "", "", "80.9"]} -{"pcdb_id": 9643, "brand_name": "Biasi", "model_name": "Riva Plus", "model_qualifier": "M90D. 28SR", "winter_efficiency_pct": 81.2, "summer_efficiency_pct": 70.5, "comparative_hot_water_efficiency_pct": 51.5, "output_kw_max": 28.4, "final_year_of_manufacture": null, "raw": ["009643", "000208", "0", "2012/Mar/27 10:12", "Biasi SpA", "Biasi", "Riva Plus", "M90D. 28SR", "41-970-09", "2002", "current", "2", "2", "1", "1", "0", "", "", "1", "2", "2", "28.4", "28.4", "", "", "81.2", "70.5", "", "51.5", "", "2", "1", "", "102", "1", "2", "170", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "84.0", "80.3", "", "", "", "", "81.0"]} -{"pcdb_id": 9644, "brand_name": "Biasi", "model_name": "Riva Plus", "model_qualifier": "M90D. 28S", "winter_efficiency_pct": 81.0, "summer_efficiency_pct": 70.9, "comparative_hot_water_efficiency_pct": 49.8, "output_kw_max": 28.4, "final_year_of_manufacture": null, "raw": ["009644", "000208", "0", "2006/Jan/17 12:31", "Biasi SpA", "Biasi", "Riva Plus", "M90D. 28S", "47-970-16", "2002", "current", "2", "2", "1", "2", "0", "", "", "1", "2", "2", "28.4", "28.4", "", "", "81.0", "70.9", "", "49.8", "", "2", "1", "", "104", "1", "2", "170", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "84.0", "80.3", "", "", "", "", "81.0"]} -{"pcdb_id": 9645, "brand_name": "Biasi", "model_name": "Riva Plus", "model_qualifier": "M90D. 24S", "winter_efficiency_pct": 80.9, "summer_efficiency_pct": 70.8, "comparative_hot_water_efficiency_pct": 49.8, "output_kw_max": 24.3, "final_year_of_manufacture": null, "raw": ["009645", "000208", "0", "2006/Jan/17 12:31", "Biasi SpA", "Biasi", "Riva Plus", "M90D. 24S", "47-970-15", "2002", "current", "2", "2", "1", "2", "0", "", "", "1", "2", "2", "24.3", "24.3", "", "", "80.9", "70.8", "", "49.8", "", "2", "1", "", "104", "1", "2", "150", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "84.1", "80.1", "", "", "", "", "80.9"]} -{"pcdb_id": 9646, "brand_name": "Biasi", "model_name": "Riva Plus", "model_qualifier": "M90D. 24SR", "winter_efficiency_pct": 81.1, "summer_efficiency_pct": 70.4, "comparative_hot_water_efficiency_pct": 51.4, "output_kw_max": 24.3, "final_year_of_manufacture": null, "raw": ["009646", "000208", "0", "2012/Mar/27 10:12", "Biasi SpA", "Biasi", "Riva Plus", "M90D. 24SR", "41-970-08", "2002", "current", "2", "2", "1", "1", "0", "", "", "1", "2", "2", "24.3", "24.3", "", "", "81.1", "70.4", "", "51.4", "", "2", "1", "", "102", "1", "2", "150", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "84.1", "80.1", "", "", "", "", "80.9"]} -{"pcdb_id": 9647, "brand_name": "Vaillant", "model_name": "Aquaplus", "model_qualifier": "", "winter_efficiency_pct": 80.7, "summer_efficiency_pct": 70.6, "comparative_hot_water_efficiency_pct": 49.6, "output_kw_max": 36.9, "final_year_of_manufacture": 2010, "raw": ["009647", "000031", "0", "2010/Jan/28 08:40", "Vaillant", "Vaillant", "Aquaplus", "", "VUI GB 362-7", "2003", "2010", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "36.9", "36.9", "", "", "80.7", "70.6", "", "49.6", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.0", "81.8", "", "", "", "", "81.8"]} -{"pcdb_id": 9648, "brand_name": "Strebel", "model_name": "SC 30 K", "model_qualifier": "", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 56.3, "output_kw_max": 25.9, "final_year_of_manufacture": null, "raw": ["009648", "000228", "0", "2010/Sep/28 09:35", "Strebel", "Strebel", "SC 30 K", "", "", "1996", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "25.9", "25.9", "", "", "88.7", "80.1", "", "56.3", "", "2", "", "", "104", "1", "2", "136", "", "0", "", "", "3", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "0", "", "0005", "", "", "", "", "", "", "", "", "89.0", "98.0", "", "", "", "", "96.3"]} -{"pcdb_id": 9649, "brand_name": "Strebel", "model_name": "SC 30 C", "model_qualifier": "", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 25.9, "final_year_of_manufacture": null, "raw": ["009649", "000228", "0", "2012/Mar/27 10:12", "Strebel", "Strebel", "SC 30 C", "", "", "1996", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "25.9", "25.9", "", "", "88.7", "79.7", "", "58.2", "", "2", "", "", "102", "1", "2", "136", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.0", "98.0", "", "", "", "", "96.3"]} -{"pcdb_id": 9650, "brand_name": "Strebel", "model_name": "SC 30 B", "model_qualifier": "", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 25.9, "final_year_of_manufacture": null, "raw": ["009650", "000228", "0", "2012/Mar/27 10:12", "Strebel", "Strebel", "SC 30 B", "", "", "1996", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "25.9", "25.9", "", "", "88.7", "79.7", "", "58.2", "", "2", "", "", "102", "1", "2", "136", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.0", "98.0", "", "", "", "", "96.3"]} -{"pcdb_id": 9651, "brand_name": "ATAG", "model_name": "Premier", "model_qualifier": "E-SHR15", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 14.4, "final_year_of_manufacture": 2007, "raw": ["009651", "000227", "0", "2012/Mar/27 10:12", "ATAG Verwarming Nederland BV", "ATAG", "Premier", "E-SHR15", "", "1999", "2007", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "14.4", "14.4", "", "", "88.6", "79.6", "", "58.2", "", "2", "", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.5", "98.2", "", "", "", "", "96.4"]} -{"pcdb_id": 9652, "brand_name": "DD Heating", "model_name": "Heatline", "model_qualifier": "S24 Compact", "winter_efficiency_pct": 80.8, "summer_efficiency_pct": 70.7, "comparative_hot_water_efficiency_pct": 49.7, "output_kw_max": 24.0, "final_year_of_manufacture": 2007, "raw": ["009652", "000215", "0", "2011/Aug/31 10:44", "Turk Demir Dokum Fab AS", "DD Heating", "Heatline", "S24 Compact", "", "2003", "2007", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "24", "24", "", "", "80.8", "70.7", "", "49.7", "", "2", "", "", "104", "1", "2", "164", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "84.1", "81.2", "", "", "", "", "81.7"]} -{"pcdb_id": 9653, "brand_name": "DD Heating", "model_name": "Heatline", "model_qualifier": "S30 Compact", "winter_efficiency_pct": 79.9, "summer_efficiency_pct": 69.8, "comparative_hot_water_efficiency_pct": 49.1, "output_kw_max": 30.0, "final_year_of_manufacture": 2007, "raw": ["009653", "000215", "0", "2011/Aug/31 10:45", "Turk Demir Dokum Fab AS", "DD Heating", "Heatline", "S30 Compact", "", "2003", "2007", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "30", "30", "", "", "79.9", "69.8", "", "49.1", "", "2", "", "", "104", "1", "2", "164", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "84.3", "79.3", "", "", "", "", "80.2"]} -{"pcdb_id": 9654, "brand_name": "DD Heating", "model_name": "Heatline", "model_qualifier": "S20 Compact", "winter_efficiency_pct": 80.2, "summer_efficiency_pct": 70.1, "comparative_hot_water_efficiency_pct": 49.3, "output_kw_max": 20.0, "final_year_of_manufacture": 2007, "raw": ["009654", "000215", "0", "2011/Aug/31 10:44", "Turk Demir Dokum Fab AS", "DD Heating", "Heatline", "S20 Compact", "", "2003", "2007", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "20", "20", "", "", "80.2", "70.1", "", "49.3", "", "2", "", "", "104", "1", "2", "164", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "83.9", "79.8", "", "", "", "", "80.6"]} -{"pcdb_id": 9655, "brand_name": "Sile SpA", "model_name": "Condensa 23 R", "model_qualifier": "", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 56.0, "output_kw_max": 22.0, "final_year_of_manufacture": null, "raw": ["009655", "000221", "0", "2008/Sep/29 16:01", "Sile SpA", "Sile SpA", "Condensa 23 R", "", "", "2002", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "22", "22", "", "", "88.2", "79.6", "", "56.0", "", "2", "", "", "104", "1", "2", "175", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "97.4", "", "", "", "", "95.6"]} -{"pcdb_id": 9656, "brand_name": "Sile SpA", "model_name": "Condensa 23 BI", "model_qualifier": "", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 80.9, "comparative_hot_water_efficiency_pct": 43.1, "output_kw_max": 22.0, "final_year_of_manufacture": null, "raw": ["009656", "000221", "0", "2024/Jan/31 10:17", "Sile SpA", "Sile SpA", "Condensa 23 BI", "", "", "2002", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "22", "22", "", "", "88.2", "80.9", "", "43.1", "", "2", "", "", "106", "1", "2", "175", "", "2", "1", "0", "48", "0", "15", "4", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "97.4", "", "", "", "", "95.6"]} -{"pcdb_id": 9657, "brand_name": "Sile SpA", "model_name": "Condensa 23 N", "model_qualifier": "", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 22.0, "final_year_of_manufacture": null, "raw": ["009657", "000221", "0", "2012/Mar/27 10:12", "Sile SpA", "Sile SpA", "Condensa 23 N", "", "", "2002", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "22", "22", "", "", "88.2", "79.2", "", "57.9", "", "2", "", "", "102", "1", "2", "175", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "97.4", "", "", "", "", "95.6"]} -{"pcdb_id": 9658, "brand_name": "Sile SpA", "model_name": "Condensa 32 N", "model_qualifier": "", "winter_efficiency_pct": 87.7, "summer_efficiency_pct": 78.7, "comparative_hot_water_efficiency_pct": 57.5, "output_kw_max": 30.0, "final_year_of_manufacture": null, "raw": ["009658", "000221", "0", "2012/Mar/27 10:12", "Sile SpA", "Sile SpA", "Condensa 32 N", "", "", "2002", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "30.0", "30.0", "", "", "87.7", "78.7", "", "57.5", "", "2", "", "", "102", "1", "2", "175", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "96.0", "", "", "", "", "94.5"]} -{"pcdb_id": 9659, "brand_name": "Sile SpA", "model_name": "Condensa 32 BI", "model_qualifier": "", "winter_efficiency_pct": 87.7, "summer_efficiency_pct": 80.4, "comparative_hot_water_efficiency_pct": 42.8, "output_kw_max": 30.0, "final_year_of_manufacture": null, "raw": ["009659", "000221", "0", "2024/Jan/31 10:17", "Sile SpA", "Sile SpA", "Condensa 32 BI", "", "", "2002", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "30", "30", "", "", "87.7", "80.4", "", "42.8", "", "2", "", "", "106", "1", "2", "175", "0", "2", "1", "0", "48", "0", "15", "4", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "96.0", "", "", "", "", "94.5"]} -{"pcdb_id": 9660, "brand_name": "Sile SpA", "model_name": "Condensa 32 Maxi", "model_qualifier": "", "winter_efficiency_pct": 87.7, "summer_efficiency_pct": 80.4, "comparative_hot_water_efficiency_pct": 35.0, "output_kw_max": 30.0, "final_year_of_manufacture": null, "raw": ["009660", "000221", "0", "2024/Jan/31 10:17", "Sile SpA", "Sile SpA", "Condensa 32 Maxi", "", "", "2002", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "30", "30", "", "", "87.7", "80.4", "", "35.0", "", "2", "", "", "106", "1", "2", "175", "0", "2", "1", "0", "120", "0", "15", "4", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "96.0", "", "", "", "", "94.5"]} -{"pcdb_id": 9661, "brand_name": "Trianco", "model_name": "Eurostar Premier 50/90", "model_qualifier": "50/90 Condensing Boiler", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 27.9, "final_year_of_manufacture": null, "raw": ["009661", "000062", "0", "2012/Mar/27 10:12", "Trianco Redfyre", "Trianco", "Eurostar Premier 50/90", "50/90 Condensing Boiler", "", "2003", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "15.7", "27.9", "", "", "88.0", "80.2", "", "58.6", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.0", "95.1", "", "", "", "", "94.1"]} -{"pcdb_id": 9663, "brand_name": "ATAG", "model_name": "Blauwe Engel", "model_qualifier": "SHR 51 L", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 48.7, "final_year_of_manufacture": 2007, "raw": ["009663", "000227", "0", "2012/Mar/27 10:12", "ATAG Verwarming Nederland bv", "ATAG", "Blauwe Engel", "SHR 51 L", "", "1996", "2007", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "48.7", "48.7", "", "", "88.3", "79.3", "", "58.0", "", "2", "", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "97.8", "", "", "", "", "95.9"]} -{"pcdb_id": 9664, "brand_name": "ATAG", "model_name": "Blauwe Engel", "model_qualifier": "SHR 51 TL", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 48.7, "final_year_of_manufacture": 2007, "raw": ["009664", "000227", "0", "2012/Mar/27 10:12", "ATAG Verwarming Nederland bv", "ATAG", "Blauwe Engel", "SHR 51 TL", "", "1996", "2007", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "48.7", "48.7", "", "", "88.3", "79.3", "", "58.0", "", "2", "", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "97.8", "", "", "", "", "95.9"]} -{"pcdb_id": 9665, "brand_name": "Chaffoteaux et Maury", "model_name": "Britony System II 100", "model_qualifier": "", "winter_efficiency_pct": 79.5, "summer_efficiency_pct": 68.8, "comparative_hot_water_efficiency_pct": 50.3, "output_kw_max": 28.0, "final_year_of_manufacture": 2007, "raw": ["009665", "000010", "0", "2012/Mar/27 10:12", "Chaffoteaux et Maury", "Chaffoteaux et Maury", "Britony System II 100", "", "GC No. 41-980-17", "2002", "2007", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "28", "28", "", "", "79.5", "68.8", "", "50.3", "", "2", "", "", "102", "1", "2", "150", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.5", "78.5", "", "", "", "", "79.2"]} -{"pcdb_id": 9666, "brand_name": "Chaffoteaux et Maury", "model_name": "Britony System II Plus 100", "model_qualifier": "", "winter_efficiency_pct": 79.5, "summer_efficiency_pct": 68.8, "comparative_hot_water_efficiency_pct": 50.3, "output_kw_max": 28.0, "final_year_of_manufacture": 2007, "raw": ["009666", "000010", "0", "2012/Mar/27 10:12", "Chaffoteaux et Maury", "Chaffoteaux et Maury", "Britony System II Plus 100", "", "GC No. 41-980-25", "2002", "2007", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "28", "28", "", "", "79.5", "68.8", "", "50.3", "", "2", "", "", "102", "1", "2", "150", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.5", "78.5", "", "", "", "", "79.2"]} -{"pcdb_id": 9667, "brand_name": "Chaffoteaux et Maury", "model_name": "Calydra Comfort 100", "model_qualifier": "", "winter_efficiency_pct": 79.3, "summer_efficiency_pct": 69.2, "comparative_hot_water_efficiency_pct": 48.7, "output_kw_max": 28.0, "final_year_of_manufacture": 2007, "raw": ["009667", "000010", "0", "2007/Jun/18 09:12", "Chaffoteaux et Maury", "Chaffoteaux et Maury", "Calydra Comfort 100", "", "GC No. 47-980-23", "2002", "2007", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "28", "28", "", "", "79.3", "69.2", "", "48.7", "", "2", "", "", "104", "1", "2", "150", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.5", "78.5", "", "", "", "", "79.2"]} -{"pcdb_id": 9668, "brand_name": "Chaffoteaux et Maury", "model_name": "Britony System II 80", "model_qualifier": "", "winter_efficiency_pct": 79.8, "summer_efficiency_pct": 69.1, "comparative_hot_water_efficiency_pct": 50.5, "output_kw_max": 24.0, "final_year_of_manufacture": 2007, "raw": ["009668", "000010", "0", "2012/Mar/27 10:12", "Chaffoteaux et Maury", "Chaffoteaux et Maury", "Britony System II 80", "", "GC No. 41-980-15", "2002", "2007", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "24", "24", "", "", "79.8", "69.1", "", "50.5", "", "2", "", "", "102", "1", "2", "150", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.6", "78.9", "", "", "", "", "79.6"]} -{"pcdb_id": 9669, "brand_name": "Chaffoteaux et Maury", "model_name": "Britony System II Plus 80", "model_qualifier": "", "winter_efficiency_pct": 79.8, "summer_efficiency_pct": 69.1, "comparative_hot_water_efficiency_pct": 50.5, "output_kw_max": 24.0, "final_year_of_manufacture": 2007, "raw": ["009669", "000010", "0", "2012/Mar/27 10:12", "Chaffoteaux et Maury", "Chaffoteaux et Maury", "Britony System II Plus 80", "", "GC No. 41-980-16", "2002", "2007", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "24", "24", "", "", "79.8", "69.1", "", "50.5", "", "2", "", "", "102", "1", "2", "150", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.6", "78.9", "", "", "", "", "79.6"]} -{"pcdb_id": 9670, "brand_name": "Beeston", "model_name": "Solution 2000", "model_qualifier": "S-HR15", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 14.5, "final_year_of_manufacture": null, "raw": ["009670", "000230", "0", "2012/Mar/27 10:12", "ATAG Verwarming Nederland BV", "Beeston", "Solution 2000", "S-HR15", "", "1997", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "14.5", "14.5", "", "", "88.6", "79.6", "", "58.2", "", "2", "", "", "102", "1", "2", "122", "5", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.5", "98.2", "", "", "", "", "96.4"]} -{"pcdb_id": 9671, "brand_name": "Beeston", "model_name": "Solution 2000", "model_qualifier": "S-HR24", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 23.0, "final_year_of_manufacture": null, "raw": ["009671", "000230", "0", "2012/Mar/27 10:12", "ATAG Verwarming Nederland BV", "Beeston", "Solution 2000", "S-HR24", "", "1997", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "23.0", "23.0", "", "", "88.6", "79.6", "", "58.2", "", "2", "", "", "102", "1", "2", "122", "5", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.5", "98.2", "", "", "", "", "96.4"]} -{"pcdb_id": 9672, "brand_name": "Beeston", "model_name": "Solution 2000", "model_qualifier": "S-HR24T", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 23.0, "final_year_of_manufacture": null, "raw": ["009672", "000230", "0", "2012/Mar/27 10:12", "ATAG Verwarming Nederland BV", "Beeston", "Solution 2000", "S-HR24T", "", "1997", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "23.0", "23.0", "", "", "88.6", "79.6", "", "58.2", "", "2", "", "", "102", "1", "2", "122", "5", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.5", "98.2", "", "", "", "", "96.4"]} -{"pcdb_id": 9673, "brand_name": "Beeston", "model_name": "Solution 2000", "model_qualifier": "S-HR35", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 33.8, "final_year_of_manufacture": null, "raw": ["009673", "000230", "0", "2012/Mar/27 10:12", "ATAG Verwarming Nederland BV", "Beeston", "Solution 2000", "S-HR35", "", "1997", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "33.8", "33.8", "", "", "88.3", "79.3", "", "57.9", "", "2", "", "", "102", "1", "2", "145", "5", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.4", "97.3", "", "", "", "", "95.6"]} -{"pcdb_id": 9674, "brand_name": "Beeston", "model_name": "Solution 2000", "model_qualifier": "S-HR35T", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 56.0, "output_kw_max": 33.8, "final_year_of_manufacture": null, "raw": ["009674", "000230", "0", "2006/Jan/17 12:31", "ATAG Verwarming Nederland BV", "Beeston", "Solution 2000", "S-HR35T", "", "1997", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "33.8", "33.8", "", "", "88.3", "79.7", "", "56.0", "", "2", "", "", "104", "1", "2", "145", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.4", "97.3", "", "", "", "", "95.6"]} -{"pcdb_id": 9675, "brand_name": "Beeston", "model_name": "Solution 2000", "model_qualifier": "S-HR51", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 48.8, "final_year_of_manufacture": null, "raw": ["009675", "000230", "0", "2012/Mar/27 10:12", "ATAG Verwarming Nederland BV", "Beeston", "Solution 2000", "S-HR51", "", "1997", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "48.8", "48.8", "", "", "88.5", "79.5", "", "58.0", "", "2", "", "", "102", "1", "2", "190", "5", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.6", "98.1", "", "", "", "", "96.1"]} -{"pcdb_id": 9676, "brand_name": "Beeston", "model_name": "Solution 2000", "model_qualifier": "S-HR51T", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 56.2, "output_kw_max": 48.8, "final_year_of_manufacture": null, "raw": ["009676", "000230", "0", "2006/Jan/17 12:31", "ATAG Verwarming Nederland BV", "Beeston", "Solution 2000", "S-HR51T", "", "1997", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "48.8", "48.8", "", "", "88.5", "79.9", "", "56.2", "", "2", "", "", "104", "1", "2", "190", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.6", "98.1", "", "", "", "", "96.1"]} -{"pcdb_id": 9677, "brand_name": "Beeston", "model_name": "Solution 2000", "model_qualifier": "S-HR60", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 57.4, "final_year_of_manufacture": null, "raw": ["009677", "000230", "0", "2012/Mar/27 10:12", "ATAG Verwarming Nederland BV", "Beeston", "Solution 2000", "S-HR60", "", "1997", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "57.4", "57.4", "", "", "88.3", "79.3", "", "57.9", "", "2", "", "", "102", "1", "2", "190", "5", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.1", "97.5", "", "", "", "", "95.7"]} -{"pcdb_id": 9678, "brand_name": "Trianco", "model_name": "Eurostar Premier", "model_qualifier": "50/90 Condensing System Boiler", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 27.9, "final_year_of_manufacture": null, "raw": ["009678", "000062", "0", "2012/Mar/27 10:12", "Trianco Redfyre", "Trianco", "Eurostar Premier", "50/90 Condensing System Boiler", "", "2003", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "15.7", "27.9", "", "", "88.0", "80.2", "", "58.6", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.0", "95.1", "", "", "", "", "94.1"]} -{"pcdb_id": 9679, "brand_name": "Fontecal", "model_name": "Corolla 30", "model_qualifier": "A", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 81.7, "comparative_hot_water_efficiency_pct": 41.5, "output_kw_max": 26.54, "final_year_of_manufacture": null, "raw": ["009679", "000231", "0", "2024/Jan/31 10:17", "Fontecal SpA", "Fontecal", "Corolla 30", "A", "", "2001", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "26.54", "26.54", "", "", "88.7", "81.7", "", "41.5", "", "2", "", "", "106", "1", "2", "65", "0.1", "2", "2", "0", "50", "0", "13", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.6", "98.4", "", "", "", "", "96.5"]} -{"pcdb_id": 9680, "brand_name": "Fontecal", "model_name": "Corolla 30", "model_qualifier": "P", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 56.3, "output_kw_max": 26.54, "final_year_of_manufacture": null, "raw": ["009680", "000231", "0", "2006/Jan/17 12:31", "Fontecal SpA", "Fontecal", "Corolla 30", "P", "", "2001", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "26.54", "26.54", "", "", "88.7", "80.1", "", "56.3", "", "2", "", "", "104", "1", "2", "65", "0.1", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.6", "98.4", "", "", "", "", "96.5"]} -{"pcdb_id": 9681, "brand_name": "Fontecal", "model_name": "Corolla 30", "model_qualifier": "S", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 26.54, "final_year_of_manufacture": null, "raw": ["009681", "000231", "0", "2012/Mar/27 10:12", "Fontecal SpA", "Fontecal", "Corolla 30", "S", "", "2001", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "26.54", "26.54", "", "", "88.7", "79.7", "", "58.2", "", "2", "", "", "102", "1", "2", "65", "0.1", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.6", "98.4", "", "", "", "", "96.5"]} -{"pcdb_id": 9695, "brand_name": "Fontecal", "model_name": "Polycal 26", "model_qualifier": "A 50", "winter_efficiency_pct": 82.9, "summer_efficiency_pct": 74.8, "comparative_hot_water_efficiency_pct": 38.0, "output_kw_max": 29.9, "final_year_of_manufacture": null, "raw": ["009695", "000231", "0", "2024/Jan/31 10:17", "Fontecal SpA", "Fontecal", "Polycal 26", "A 50", "", "2002", "current", "4", "1", "1", "2", "0", "", "", "1", "2", "2", "29.9", "29.9", "", "", "82.9", "74.8", "", "38.0", "", "2", "", "", "203", "1", "1", "110", "0.1", "2", "2", "0", "50", "0", "13", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.2", "83.8", "", "", "", "", "84.0"]} -{"pcdb_id": 9696, "brand_name": "Fontecal", "model_name": "Polycal 26", "model_qualifier": "A 100", "winter_efficiency_pct": 83.2, "summer_efficiency_pct": 75.1, "comparative_hot_water_efficiency_pct": 32.5, "output_kw_max": 29.9, "final_year_of_manufacture": null, "raw": ["009696", "000231", "0", "2024/Jan/31 10:17", "Fontecal SpA", "Fontecal", "Polycal 26", "A 100", "", "2002", "current", "4", "1", "1", "2", "0", "", "", "1", "2", "2", "29.9", "29.9", "", "", "83.2", "75.1", "", "32.5", "", "2", "", "", "203", "1", "1", "110", "0.1", "2", "2", "0", "100", "0", "13", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.2", "83.8", "", "", "", "", "84.0"]} -{"pcdb_id": 9698, "brand_name": "Fontecal", "model_name": "Polycal 26", "model_qualifier": "S", "winter_efficiency_pct": 84.5, "summer_efficiency_pct": 72.8, "comparative_hot_water_efficiency_pct": 53.2, "output_kw_max": 29.9, "final_year_of_manufacture": null, "raw": ["009698", "000231", "0", "2012/Mar/27 10:12", "Fontecal SpA", "Fontecal", "Polycal 26", "S", "", "2002", "current", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "29.9", "29.9", "", "", "84.5", "72.8", "", "53.2", "", "2", "", "", "201", "1", "1", "110", "0.1", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.2", "83.8", "", "", "", "", "84.0"]} -{"pcdb_id": 9699, "brand_name": "Fontecal", "model_name": "Polycal 21", "model_qualifier": "A 50", "winter_efficiency_pct": 82.9, "summer_efficiency_pct": 74.8, "comparative_hot_water_efficiency_pct": 38.0, "output_kw_max": 24.5, "final_year_of_manufacture": null, "raw": ["009699", "000231", "0", "2024/Jan/31 10:17", "Fontecal SpA", "Fontecal", "Polycal 21", "A 50", "", "2002", "current", "4", "1", "1", "2", "0", "", "", "1", "2", "2", "24.5", "24.5", "", "", "82.9", "74.8", "", "38.0", "", "2", "", "", "203", "1", "1", "110", "0.1", "2", "2", "0", "50", "0", "13", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.2", "83.8", "", "", "", "", "84.0"]} -{"pcdb_id": 9700, "brand_name": "Fontecal", "model_name": "Polycal 21", "model_qualifier": "A 100", "winter_efficiency_pct": 83.2, "summer_efficiency_pct": 75.1, "comparative_hot_water_efficiency_pct": 32.5, "output_kw_max": 24.5, "final_year_of_manufacture": null, "raw": ["009700", "000231", "0", "2024/Jan/31 10:17", "Fontecal SpA", "Fontecal", "Polycal 21", "A 100", "", "2002", "current", "4", "1", "1", "2", "0", "", "", "1", "2", "2", "24.5", "24.5", "", "", "83.2", "75.1", "", "32.5", "", "2", "", "", "203", "1", "1", "110", "0.1", "2", "2", "0", "100", "0", "13", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.2", "83.8", "", "", "", "", "84.0"]} -{"pcdb_id": 9702, "brand_name": "Fontecal", "model_name": "Polycal 21", "model_qualifier": "S", "winter_efficiency_pct": 84.5, "summer_efficiency_pct": 72.8, "comparative_hot_water_efficiency_pct": 53.2, "output_kw_max": 24.5, "final_year_of_manufacture": null, "raw": ["009702", "000231", "0", "2012/Mar/27 10:12", "Fontecal SpA", "Fontecal", "Polycal 21", "S", "", "2002", "current", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "24.5", "24.5", "", "", "84.5", "72.8", "", "53.2", "", "2", "", "", "201", "1", "1", "110", "0.1", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.2", "83.8", "", "", "", "", "84.0"]} -{"pcdb_id": 9704, "brand_name": "Fontecal", "model_name": "Digit", "model_qualifier": "XER", "winter_efficiency_pct": 83.1, "summer_efficiency_pct": 73.0, "comparative_hot_water_efficiency_pct": 51.3, "output_kw_max": 23.2, "final_year_of_manufacture": null, "raw": ["009704", "000231", "0", "2006/Jan/17 12:31", "Fontecal SpA", "Fontecal", "Digit", "XER", "", "2000", "current", "2", "2", "1", "2", "0", "", "", "1", "2", "2", "23.2", "23.2", "", "", "83.1", "73.0", "", "51.3", "", "2", "0", "", "104", "1", "2", "47", "0.1", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "85.3", "86.6", "", "", "", "", "86.3"]} -{"pcdb_id": 9708, "brand_name": "British Gas", "model_name": "RD", "model_qualifier": "428 System", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 27.7, "final_year_of_manufacture": null, "raw": ["009708", "000035", "0", "2012/Mar/27 10:12", "Worcester Heat Systems", "British Gas", "RD", "428 System", "41 108 07", "2003", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "27.7", "27.7", "", "", "88.1", "79.1", "", "57.8", "", "2", "", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.9", "96.8", "", "", "", "", "95.3"]} -{"pcdb_id": 9709, "brand_name": "British Gas", "model_name": "RD", "model_qualifier": "430i System", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 29.5, "final_year_of_manufacture": null, "raw": ["009709", "000035", "0", "2012/Mar/27 10:12", "Worcester Heat Systems", "British Gas", "RD", "430i System", "41 108 06", "2003", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "29.5", "29.5", "", "", "88.1", "79.1", "", "57.8", "", "2", "", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.9", "96.8", "", "", "", "", "95.3"]} -{"pcdb_id": 9710, "brand_name": "British Gas", "model_name": "RD", "model_qualifier": "537i Combi", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 56.5, "output_kw_max": 37.5, "final_year_of_manufacture": null, "raw": ["009710", "000035", "0", "2003/Aug/29 10:20", "Worcester Heat Systems", "British Gas", "RD", "537i Combi", "47 108 11", "2003", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "37.5", "37.5", "", "", "88.9", "80.3", "", "56.5", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.5", "98.9", "", "", "", "", "96.9"]} -{"pcdb_id": 9711, "brand_name": "British Gas", "model_name": "RD", "model_qualifier": "532 Combi", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 56.5, "output_kw_max": 32.5, "final_year_of_manufacture": null, "raw": ["009711", "000035", "0", "2003/Aug/29 10:20", "Worcester Heat Systems", "British Gas", "RD", "532 Combi", "47 108 13", "2003", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "32.5", "32.5", "", "", "88.9", "80.3", "", "56.5", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.5", "98.9", "", "", "", "", "96.9"]} -{"pcdb_id": 9712, "brand_name": "British Gas", "model_name": "RD", "model_qualifier": "532i Combi", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 56.5, "output_kw_max": 32.5, "final_year_of_manufacture": null, "raw": ["009712", "000035", "0", "2003/Aug/29 10:20", "Worcester Heat Systems", "British Gas", "RD", "532i Combi", "47 311 10", "2003", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "32.5", "32.5", "", "", "88.9", "80.3", "", "56.5", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.5", "98.9", "", "", "", "", "96.9"]} -{"pcdb_id": 9713, "brand_name": "British Gas", "model_name": "RD", "model_qualifier": "542i Combi", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 56.1, "output_kw_max": 40.0, "final_year_of_manufacture": null, "raw": ["009713", "000035", "0", "2006/Jan/17 12:31", "Worcester Heat Systems", "British Gas", "RD", "542i Combi", "47 311 12", "2003", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "40.0", "40.0", "", "", "88.3", "79.7", "", "56.1", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "97.7", "", "", "", "", "95.8"]} -{"pcdb_id": 9714, "brand_name": "Worcester", "model_name": "Greenstar R", "model_qualifier": "30HE Plus Combi", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 55.9, "output_kw_max": 29.5, "final_year_of_manufacture": 2006, "raw": ["009714", "000035", "0", "2020/Sep/04 08:05", "Worcester Heat Systems", "Worcester", "Greenstar R", "30HE Plus Combi", "47 311 79", "2003", "2006", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "29.5", "29.5", "", "", "88.1", "79.5", "", "55.9", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.9", "96.8", "", "", "", "", "95.3"]} -{"pcdb_id": 9715, "brand_name": "Worcester", "model_name": "Greenstar R", "model_qualifier": "35 HE Plus Combi", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 56.5, "output_kw_max": 35.5, "final_year_of_manufacture": 2006, "raw": ["009715", "000035", "0", "2020/Sep/04 08:05", "Worcester Heat Systems", "Worcester", "Greenstar R", "35 HE Plus Combi", "47 311 80", "2003", "2006", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "35.5", "35.5", "", "", "88.9", "80.3", "", "56.5", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.5", "98.9", "", "", "", "", "96.9"]} -{"pcdb_id": 9716, "brand_name": "Worcester", "model_name": "Greenstar R", "model_qualifier": "25 HE Combi", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 55.9, "output_kw_max": 27.5, "final_year_of_manufacture": 2006, "raw": ["009716", "000035", "0", "2020/Sep/04 08:05", "Worcester Heat Systems", "Worcester", "Greenstar R", "25 HE Combi", "47 311 77", "2003", "2006", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "27.5", "27.5", "", "", "88.1", "79.5", "", "55.9", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.9", "96.8", "", "", "", "", "95.3"]} -{"pcdb_id": 9717, "brand_name": "Worcester", "model_name": "Greenstar R", "model_qualifier": "29 HE Conventional", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 27.7, "final_year_of_manufacture": 2006, "raw": ["009717", "000035", "0", "2020/Sep/04 08:06", "Worcester Heat Systems", "Worcester", "Greenstar R", "29 HE Conventional", "41 311 60", "2003", "2006", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "27.7", "27.7", "", "", "88.1", "79.1", "", "57.8", "", "2", "", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.9", "96.8", "", "", "", "", "95.3"]} -{"pcdb_id": 9718, "brand_name": "Worcester", "model_name": "Greenstar R", "model_qualifier": "28 HE System", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 27.7, "final_year_of_manufacture": 2006, "raw": ["009718", "000035", "0", "2020/Sep/04 08:06", "Worcester Heat Systems", "Worcester", "Greenstar R", "28 HE System", "41 311 62", "2003", "2006", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "27.7", "27.7", "", "", "88.1", "79.1", "", "57.8", "", "2", "", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.9", "96.8", "", "", "", "", "95.3"]} -{"pcdb_id": 9719, "brand_name": "Worcester", "model_name": "Greenstar R", "model_qualifier": "30 HE Combi", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 55.9, "output_kw_max": 29.5, "final_year_of_manufacture": 2006, "raw": ["009719", "000035", "0", "2020/Sep/04 08:06", "Worcester Heat Systems", "Worcester", "Greenstar R", "30 HE Combi", "47 311 78", "2003", "2006", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "29.5", "29.5", "", "", "88.1", "79.5", "", "55.9", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.9", "96.8", "", "", "", "", "95.3"]} -{"pcdb_id": 9720, "brand_name": "Worcester", "model_name": "Greenstar R", "model_qualifier": "40 HE Plus Combi", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 56.1, "output_kw_max": 40.0, "final_year_of_manufacture": 2006, "raw": ["009720", "000035", "0", "2020/Sep/04 08:06", "Worcester Heat Systems", "Worcester", "Greenstar R", "40 HE Plus Combi", "47 311 81", "2003", "2006", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "40.0", "40.0", "", "", "88.3", "79.7", "", "56.1", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "97.7", "", "", "", "", "95.8"]} -{"pcdb_id": 9721, "brand_name": "Worcester", "model_name": "Greenstar R", "model_qualifier": "40 HE Conventional", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 40.0, "final_year_of_manufacture": 2006, "raw": ["009721", "000035", "0", "2020/Sep/04 08:06", "Worcester Heat Systems", "Worcester", "Greenstar R", "40 HE Conventional", "41 311 61", "2003", "2006", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "40.0", "40.0", "", "", "88.3", "79.3", "", "57.9", "", "2", "", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "97.7", "", "", "", "", "95.8"]} -{"pcdb_id": 9722, "brand_name": "Ferroli", "model_name": "Maxima", "model_qualifier": "35C", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 56.4, "output_kw_max": 34.6, "final_year_of_manufacture": 2008, "raw": ["009722", "000097", "0", "2009/Nov/25 16:29", "Ferroli SpA", "Ferroli", "Maxima", "35C", "", "2003", "2008", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "34.6", "34.6", "", "", "88.9", "80.3", "", "56.4", "", "2", "", "", "104", "1", "2", "150", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "", "0", "0005", "", "", "", "", "", "", "", "", "89.6", "98.3", "", "", "", "", "96.7"]} -{"pcdb_id": 9723, "brand_name": "Vokera", "model_name": "Linea", "model_qualifier": "726", "winter_efficiency_pct": 82.0, "summer_efficiency_pct": 71.9, "comparative_hot_water_efficiency_pct": 50.5, "output_kw_max": 26.0, "final_year_of_manufacture": 2010, "raw": ["009723", "000011", "0", "2010/Oct/21 11:14", "Vokera", "Vokera", "Linea", "726", "4709440", "2003", "2010", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "26.0", "26.0", "", "", "82.0", "71.9", "", "50.5", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "83.1", "83.4", "", "", "", "", "83.4"]} -{"pcdb_id": 9724, "brand_name": "Vokera", "model_name": "Linea", "model_qualifier": "726 LPG", "winter_efficiency_pct": 83.1, "summer_efficiency_pct": 73.0, "comparative_hot_water_efficiency_pct": 51.3, "output_kw_max": 26.0, "final_year_of_manufacture": 2010, "raw": ["009724", "000011", "0", "2010/Oct/21 11:14", "Vokera", "Vokera", "Linea", "726 LPG", "4709441", "2003", "2010", "2", "2", "1", "2", "0", "", "", "1", "2", "2", "26.0", "26.0", "", "", "83.1", "73.0", "", "51.3", "", "2", "0", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "86.1", "87.3", "", "", "", "", "87.1"]} -{"pcdb_id": 9725, "brand_name": "Vokera", "model_name": "Linea", "model_qualifier": "730", "winter_efficiency_pct": 82.7, "summer_efficiency_pct": 72.6, "comparative_hot_water_efficiency_pct": 51.0, "output_kw_max": 30.1, "final_year_of_manufacture": 2010, "raw": ["009725", "000011", "0", "2010/Oct/21 11:14", "Vokera", "Vokera", "Linea", "730", "4709442", "2003", "2010", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "30.1", "30.1", "", "", "82.7", "72.6", "", "51.0", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "83.3", "84.9", "", "", "", "", "84.6"]} -{"pcdb_id": 9726, "brand_name": "Vokera", "model_name": "Linea", "model_qualifier": "730 LPG", "winter_efficiency_pct": 83.1, "summer_efficiency_pct": 73.0, "comparative_hot_water_efficiency_pct": 51.3, "output_kw_max": 30.1, "final_year_of_manufacture": 2010, "raw": ["009726", "000011", "0", "2010/Oct/21 11:14", "Vokera", "Vokera", "Linea", "730 LPG", "4709443", "2003", "2010", "2", "2", "1", "2", "0", "", "", "1", "2", "2", "30.1", "30.1", "", "", "83.1", "73.0", "", "51.3", "", "2", "0", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "85.8", "87.0", "", "", "", "", "86.8"]} -{"pcdb_id": 9727, "brand_name": "Vokera", "model_name": "Linea", "model_qualifier": "735", "winter_efficiency_pct": 82.8, "summer_efficiency_pct": 72.7, "comparative_hot_water_efficiency_pct": 51.1, "output_kw_max": 35.2, "final_year_of_manufacture": 2010, "raw": ["009727", "000011", "0", "2010/Oct/21 11:14", "Vokera", "Vokera", "Linea", "735", "4709444", "2003", "2010", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "35.2", "35.2", "", "", "82.8", "72.7", "", "51.1", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "84.0", "85.1", "", "", "", "", "84.9"]} -{"pcdb_id": 9728, "brand_name": "Vokera", "model_name": "Linea", "model_qualifier": "735 LPG", "winter_efficiency_pct": 83.1, "summer_efficiency_pct": 73.0, "comparative_hot_water_efficiency_pct": 51.3, "output_kw_max": 35.2, "final_year_of_manufacture": 2010, "raw": ["009728", "000011", "0", "2010/Oct/21 11:15", "Vokera", "Vokera", "Linea", "735 LPG", "4709445", "2003", "2010", "2", "2", "1", "2", "0", "", "", "1", "2", "2", "35.2", "35.2", "", "", "83.1", "73.0", "", "51.3", "", "2", "0", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "86.2", "88.0", "", "", "", "", "87.6"]} -{"pcdb_id": 9729, "brand_name": "Vokera", "model_name": "Mynute", "model_qualifier": "35e", "winter_efficiency_pct": 83.0, "summer_efficiency_pct": 72.3, "comparative_hot_water_efficiency_pct": 52.8, "output_kw_max": 35.2, "final_year_of_manufacture": 2010, "raw": ["009729", "000011", "0", "2012/Mar/27 10:12", "Vokera", "Vokera", "Mynute", "35e", "4109429", "2003", "2010", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "35.2", "35.2", "", "", "83.0", "72.3", "", "52.8", "", "2", "", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "84.0", "85.1", "", "", "", "", "84.9"]} -{"pcdb_id": 9730, "brand_name": "Vokera", "model_name": "Mynute", "model_qualifier": "35e LPG", "winter_efficiency_pct": 83.3, "summer_efficiency_pct": 72.6, "comparative_hot_water_efficiency_pct": 53.0, "output_kw_max": 35.2, "final_year_of_manufacture": 2010, "raw": ["009730", "000011", "0", "2012/Mar/27 10:12", "Vokera", "Vokera", "Mynute", "35e LPG", "4109430", "2003", "2010", "2", "2", "1", "1", "0", "", "", "1", "2", "2", "35.2", "35.2", "", "", "83.3", "72.6", "", "53.0", "", "2", "0", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "86.2", "88.0", "", "", "", "", "87.6"]} -{"pcdb_id": 9731, "brand_name": "Biasi", "model_name": "Garda", "model_qualifier": "M90F. 32S", "winter_efficiency_pct": 79.2, "summer_efficiency_pct": 69.1, "comparative_hot_water_efficiency_pct": 48.6, "output_kw_max": 35.2, "final_year_of_manufacture": 2007, "raw": ["009731", "000208", "0", "2008/May/22 11:33", "Biasi", "Biasi", "Garda", "M90F. 32S", "47-970-22", "2003", "2007", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "35.2", "35.2", "", "", "79.2", "69.1", "", "48.6", "", "2", "", "", "104", "1", "2", "180", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.0", "78.7", "", "", "", "", "79.4"]} -{"pcdb_id": 9732, "brand_name": "Biasi", "model_name": "Riva Compact", "model_qualifier": "M90E. 32S", "winter_efficiency_pct": 79.2, "summer_efficiency_pct": 69.1, "comparative_hot_water_efficiency_pct": 48.6, "output_kw_max": 35.2, "final_year_of_manufacture": null, "raw": ["009732", "000208", "0", "2006/Jan/17 12:31", "Biasi", "Biasi", "Riva Compact", "M90E. 32S", "47-970-21", "2003", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "35.2", "35.2", "", "", "79.2", "69.1", "", "48.6", "", "2", "", "", "104", "1", "2", "180", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.0", "78.7", "", "", "", "", "79.4"]} -{"pcdb_id": 9733, "brand_name": "Grant", "model_name": "Vortex", "model_qualifier": "Utility 15-26", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 81.3, "comparative_hot_water_efficiency_pct": 59.4, "output_kw_max": 26.0, "final_year_of_manufacture": null, "raw": ["009733", "000048", "0", "2012/Mar/27 10:12", "Grant Engineering", "Grant", "Vortex", "Utility 15-26", "", "2003", "current", "4", "1", "1", "1", "0", "", "", "2", "2", "2", "15", "26", "", "", "89.1", "81.3", "", "59.4", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "93.6", "96.4", "", "", "", "", "95.9"]} -{"pcdb_id": 9734, "brand_name": "Grant", "model_name": "Vortex", "model_qualifier": "Utility System 15-26S", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 81.3, "comparative_hot_water_efficiency_pct": 59.4, "output_kw_max": 26.0, "final_year_of_manufacture": null, "raw": ["009734", "000048", "0", "2012/Mar/27 10:12", "Grant Engineering", "Grant", "Vortex", "Utility System 15-26S", "", "2003", "current", "4", "1", "1", "1", "0", "", "", "2", "2", "2", "15", "26", "", "", "89.1", "81.3", "", "59.4", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "93.6", "96.4", "", "", "", "", "95.9"]} -{"pcdb_id": 9735, "brand_name": "Grant", "model_name": "Vortex", "model_qualifier": "36", "winter_efficiency_pct": 90.5, "summer_efficiency_pct": 82.7, "comparative_hot_water_efficiency_pct": 60.4, "output_kw_max": 36.0, "final_year_of_manufacture": null, "raw": ["009735", "000048", "0", "2012/Mar/27 10:12", "Grant Engineering", "Grant", "Vortex", "36", "", "2003", "current", "4", "1", "1", "1", "0", "", "", "2", "2", "2", "36", "36", "", "", "90.5", "82.7", "", "60.4", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "95.1", "99.3", "", "", "", "", "98.5"]} -{"pcdb_id": 9736, "brand_name": "Grant", "model_name": "Vortex", "model_qualifier": "36S", "winter_efficiency_pct": 90.5, "summer_efficiency_pct": 82.7, "comparative_hot_water_efficiency_pct": 60.4, "output_kw_max": 36.0, "final_year_of_manufacture": null, "raw": ["009736", "000048", "0", "2012/Mar/27 10:12", "Grant Engineering", "Grant", "Vortex", "36S", "", "2003", "current", "4", "1", "1", "1", "0", "", "", "2", "2", "2", "36", "36", "", "", "90.5", "82.7", "", "60.4", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "95.1", "99.3", "", "", "", "", "98.5"]} -{"pcdb_id": 9737, "brand_name": "Ravenheat", "model_name": "Silver Star 24", "model_qualifier": "", "winter_efficiency_pct": 80.5, "summer_efficiency_pct": 70.4, "comparative_hot_water_efficiency_pct": 49.5, "output_kw_max": 24.1, "final_year_of_manufacture": null, "raw": ["009737", "000026", "0", "2006/Jan/17 12:31", "Ravenheat", "Ravenheat", "Silver Star 24", "", "", "2003", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "24.1", "24.1", "", "", "80.5", "70.4", "", "49.5", "", "2", "", "", "104", "1", "2", "150", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "83.3", "80.5", "", "", "", "", "81.1"]} -{"pcdb_id": 9738, "brand_name": "Ravenheat", "model_name": "Silver Star 24 LPG", "model_qualifier": "", "winter_efficiency_pct": 82.3, "summer_efficiency_pct": 72.2, "comparative_hot_water_efficiency_pct": 50.8, "output_kw_max": 24.1, "final_year_of_manufacture": null, "raw": ["009738", "000026", "0", "2006/Jan/17 12:31", "Ravenheat", "Ravenheat", "Silver Star 24 LPG", "", "", "2003", "current", "2", "2", "1", "2", "0", "", "", "1", "2", "2", "24.1", "24.1", "", "", "82.3", "72.2", "", "50.8", "", "2", "0", "", "104", "1", "2", "150", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "", "", "0004", "", "", "", "", "", "", "", "", "85.1", "82.3", "", "", "", "", "82.9"]} -{"pcdb_id": 9739, "brand_name": "Ravenheat", "model_name": "Silver Star 24T", "model_qualifier": "", "winter_efficiency_pct": 80.5, "summer_efficiency_pct": 70.4, "comparative_hot_water_efficiency_pct": 49.5, "output_kw_max": 24.1, "final_year_of_manufacture": null, "raw": ["009739", "000026", "0", "2006/Jan/17 12:31", "Ravenheat", "Ravenheat", "Silver Star 24T", "", "", "2003", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "24.1", "24.1", "", "", "80.5", "70.4", "", "49.5", "", "2", "", "", "104", "1", "2", "150", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "", "", "0004", "", "", "", "", "", "", "", "", "83.3", "80.5", "", "", "", "", "81.1"]} -{"pcdb_id": 9740, "brand_name": "Ravenheat", "model_name": "Silver Star 24T LPG", "model_qualifier": "", "winter_efficiency_pct": 82.3, "summer_efficiency_pct": 72.2, "comparative_hot_water_efficiency_pct": 50.8, "output_kw_max": 24.1, "final_year_of_manufacture": null, "raw": ["009740", "000026", "0", "2006/Jan/17 12:31", "Ravenheat", "Ravenheat", "Silver Star 24T LPG", "", "", "2003", "current", "2", "2", "1", "2", "0", "", "", "1", "2", "2", "24.1", "24.1", "", "", "82.3", "72.2", "", "50.8", "", "2", "0", "", "104", "1", "2", "150", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "85.1", "82.3", "", "", "", "", "82.9"]} -{"pcdb_id": 9741, "brand_name": "Ravenheat", "model_name": "Silver Star 29", "model_qualifier": "", "winter_efficiency_pct": 80.5, "summer_efficiency_pct": 70.4, "comparative_hot_water_efficiency_pct": 49.5, "output_kw_max": 29.0, "final_year_of_manufacture": null, "raw": ["009741", "000026", "0", "2006/Jan/17 12:31", "Ravenheat", "Ravenheat", "Silver Star 29", "", "", "2003", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "29.0", "29.0", "", "", "80.5", "70.4", "", "49.5", "", "2", "", "", "104", "1", "2", "150", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "", "", "0004", "", "", "", "", "", "", "", "", "83.3", "80.5", "", "", "", "", "81.1"]} -{"pcdb_id": 9742, "brand_name": "Ravenheat", "model_name": "Silver Star 29 LPG", "model_qualifier": "", "winter_efficiency_pct": 82.3, "summer_efficiency_pct": 72.2, "comparative_hot_water_efficiency_pct": 50.8, "output_kw_max": 29.0, "final_year_of_manufacture": null, "raw": ["009742", "000026", "0", "2006/Jan/17 12:31", "Ravenheat", "Ravenheat", "Silver Star 29 LPG", "", "", "2003", "current", "2", "2", "1", "2", "0", "", "", "1", "2", "2", "29", "29", "", "", "82.3", "72.2", "", "50.8", "", "2", "0", "", "104", "1", "2", "150", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "", "", "0004", "", "", "", "", "", "", "", "", "85.1", "82.3", "", "", "", "", "82.9"]} -{"pcdb_id": 9743, "brand_name": "Ravenheat", "model_name": "Silver Star 29T", "model_qualifier": "", "winter_efficiency_pct": 80.5, "summer_efficiency_pct": 70.4, "comparative_hot_water_efficiency_pct": 49.5, "output_kw_max": 29.0, "final_year_of_manufacture": null, "raw": ["009743", "000026", "0", "2006/Jan/17 12:31", "Ravenheat", "Ravenheat", "Silver Star 29T", "", "", "2003", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "29.0", "29.0", "", "", "80.5", "70.4", "", "49.5", "", "2", "", "", "104", "1", "2", "150", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "", "", "0004", "", "", "", "", "", "", "", "", "83.3", "80.5", "", "", "", "", "81.1"]} -{"pcdb_id": 9744, "brand_name": "Ravenheat", "model_name": "Silver Star 29T LPG", "model_qualifier": "", "winter_efficiency_pct": 82.3, "summer_efficiency_pct": 72.2, "comparative_hot_water_efficiency_pct": 50.8, "output_kw_max": 29.0, "final_year_of_manufacture": null, "raw": ["009744", "000026", "0", "2006/Jan/17 12:31", "Ravenheat", "Ravenheat", "Silver Star 29T LPG", "", "", "2003", "current", "2", "2", "1", "2", "0", "", "", "1", "2", "2", "29.0", "29.0", "", "", "82.3", "72.2", "", "50.8", "", "2", "0", "", "104", "1", "2", "150", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "", "", "0004", "", "", "", "", "", "", "", "", "85.1", "82.3", "", "", "", "", "82.9"]} -{"pcdb_id": 9745, "brand_name": "Ravenheat", "model_name": "White Star 29", "model_qualifier": "", "winter_efficiency_pct": 80.5, "summer_efficiency_pct": 70.4, "comparative_hot_water_efficiency_pct": 49.5, "output_kw_max": 29.0, "final_year_of_manufacture": null, "raw": ["009745", "000026", "0", "2006/Jan/17 12:31", "Ravenheat", "Ravenheat", "White Star 29", "", "", "2003", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "29.0", "29.0", "", "", "80.5", "70.4", "", "49.5", "", "2", "", "", "104", "1", "2", "150", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "", "", "0004", "", "", "", "", "", "", "", "", "83.3", "80.5", "", "", "", "", "81.1"]} -{"pcdb_id": 9746, "brand_name": "Ravenheat", "model_name": "White Star 29 LPG", "model_qualifier": "", "winter_efficiency_pct": 82.3, "summer_efficiency_pct": 72.2, "comparative_hot_water_efficiency_pct": 50.8, "output_kw_max": 29.0, "final_year_of_manufacture": null, "raw": ["009746", "000026", "0", "2006/Jan/17 12:31", "Ravenheat", "Ravenheat", "White Star 29 LPG", "", "", "2003", "current", "2", "2", "1", "2", "0", "", "", "1", "2", "2", "29.0", "29.0", "", "", "82.3", "72.2", "", "50.8", "", "2", "0", "", "104", "1", "2", "150", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "", "", "0004", "", "", "", "", "", "", "", "", "85.1", "82.3", "", "", "", "", "82.9"]} -{"pcdb_id": 9747, "brand_name": "Ravenheat", "model_name": "White Star 29T", "model_qualifier": "", "winter_efficiency_pct": 80.5, "summer_efficiency_pct": 70.4, "comparative_hot_water_efficiency_pct": 49.5, "output_kw_max": 29.0, "final_year_of_manufacture": null, "raw": ["009747", "000026", "0", "2006/Jan/17 12:31", "Ravenheat", "Ravenheat", "White Star 29T", "", "", "2003", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "29", "29", "", "", "80.5", "70.4", "", "49.5", "", "2", "", "", "104", "1", "2", "150", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "", "", "0004", "", "", "", "", "", "", "", "", "83.3", "80.5", "", "", "", "", "81.1"]} -{"pcdb_id": 9748, "brand_name": "Ravenheat", "model_name": "White Star 29T LPG", "model_qualifier": "", "winter_efficiency_pct": 82.3, "summer_efficiency_pct": 72.2, "comparative_hot_water_efficiency_pct": 50.8, "output_kw_max": 29.0, "final_year_of_manufacture": null, "raw": ["009748", "000026", "0", "2006/Jan/17 12:31", "Ravenheat", "Ravenheat", "White Star 29T LPG", "", "", "2003", "current", "2", "2", "1", "2", "0", "", "", "1", "2", "2", "29", "29", "", "", "82.3", "72.2", "", "50.8", "", "2", "0", "", "104", "1", "2", "150", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "", "", "0004", "", "", "", "", "", "", "", "", "85.1", "82.3", "", "", "", "", "82.9"]} -{"pcdb_id": 9749, "brand_name": "Ravenheat", "model_name": "White Star 24", "model_qualifier": "", "winter_efficiency_pct": 80.5, "summer_efficiency_pct": 70.4, "comparative_hot_water_efficiency_pct": 49.5, "output_kw_max": 24.1, "final_year_of_manufacture": null, "raw": ["009749", "000026", "0", "2006/Jan/17 12:31", "Ravenheat", "Ravenheat", "White Star 24", "", "", "2003", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "24.1", "24.1", "", "", "80.5", "70.4", "", "49.5", "", "2", "", "", "104", "1", "2", "150", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "", "", "0004", "", "", "", "", "", "", "", "", "83.3", "80.5", "", "", "", "", "81.1"]} -{"pcdb_id": 9750, "brand_name": "Ravenheat", "model_name": "White Star 24 LPG", "model_qualifier": "", "winter_efficiency_pct": 82.3, "summer_efficiency_pct": 72.2, "comparative_hot_water_efficiency_pct": 50.8, "output_kw_max": 24.1, "final_year_of_manufacture": null, "raw": ["009750", "000026", "0", "2006/Jan/17 12:31", "Ravenheat", "Ravenheat", "White Star 24 LPG", "", "", "2003", "current", "2", "2", "1", "2", "0", "", "", "1", "2", "2", "24.1", "24.1", "", "", "82.3", "72.2", "", "50.8", "", "2", "0", "", "104", "1", "2", "150", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "", "", "0004", "", "", "", "", "", "", "", "", "85.1", "82.3", "", "", "", "", "82.9"]} -{"pcdb_id": 9751, "brand_name": "Ravenheat", "model_name": "White Star 24T", "model_qualifier": "", "winter_efficiency_pct": 80.5, "summer_efficiency_pct": 70.4, "comparative_hot_water_efficiency_pct": 49.5, "output_kw_max": 24.1, "final_year_of_manufacture": null, "raw": ["009751", "000026", "0", "2006/Jan/17 12:31", "Ravenheat", "Ravenheat", "White Star 24T", "", "", "2003", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "24.1", "24.1", "", "", "80.5", "70.4", "", "49.5", "", "2", "", "", "104", "1", "2", "150", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "", "", "0004", "", "", "", "", "", "", "", "", "83.3", "80.5", "", "", "", "", "81.1"]} -{"pcdb_id": 9752, "brand_name": "Ravenheat", "model_name": "White Star 24T LPG", "model_qualifier": "", "winter_efficiency_pct": 82.3, "summer_efficiency_pct": 72.2, "comparative_hot_water_efficiency_pct": 50.8, "output_kw_max": 24.1, "final_year_of_manufacture": null, "raw": ["009752", "000026", "0", "2006/Jan/17 12:31", "Ravenheat", "Ravenheat", "White Star 24T LPG", "", "", "2003", "current", "2", "2", "1", "2", "0", "", "", "1", "2", "2", "24.1", "24.1", "", "", "82.3", "72.2", "", "50.8", "", "2", "0", "", "104", "1", "2", "150", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "", "", "0004", "", "", "", "", "", "", "", "", "85.1", "82.3", "", "", "", "", "82.9"]} -{"pcdb_id": 9753, "brand_name": "Ravenheat", "model_name": "HE 85A T LPG", "model_qualifier": "", "winter_efficiency_pct": 90.6, "summer_efficiency_pct": 82.0, "comparative_hot_water_efficiency_pct": 57.6, "output_kw_max": 25.6, "final_year_of_manufacture": null, "raw": ["009753", "000026", "0", "2006/Jan/17 12:31", "Ravenheat", "Ravenheat", "HE 85A T LPG", "", "", "2003", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "25.6", "25.6", "", "", "90.6", "82.0", "", "57.6", "", "2", "0", "", "104", "1", "2", "60", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "0", "", "0005", "", "", "", "", "", "", "", "", "90.9", "100.1", "", "", "", "", "98.4"]} -{"pcdb_id": 9754, "brand_name": "Ravenheat", "model_name": "HE 85A T", "model_qualifier": "", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 56.8, "output_kw_max": 25.6, "final_year_of_manufacture": null, "raw": ["009754", "000026", "0", "2006/Jan/17 12:31", "Ravenheat", "Ravenheat", "HE 85A T", "", "", "2003", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "25.6", "25.6", "", "", "89.4", "80.8", "", "56.8", "", "2", "", "", "104", "1", "2", "60", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "0", "", "0005", "", "", "", "", "", "", "", "", "88.9", "100.0", "", "", "", "", "97.9"]} -{"pcdb_id": 9755, "brand_name": "Ravenheat", "model_name": "HE 85 A LPG", "model_qualifier": "", "winter_efficiency_pct": 90.6, "summer_efficiency_pct": 82.0, "comparative_hot_water_efficiency_pct": 57.6, "output_kw_max": 25.6, "final_year_of_manufacture": null, "raw": ["009755", "000026", "0", "2006/Jan/17 12:31", "Ravenheat", "Ravenheat", "HE 85 A LPG", "", "", "2003", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "25.6", "25.6", "", "", "90.6", "82.0", "", "57.6", "", "2", "0", "", "104", "1", "2", "60", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "0", "", "0005", "", "", "", "", "", "", "", "", "90.9", "100.1", "", "", "", "", "98.4"]} -{"pcdb_id": 9756, "brand_name": "Ravenheat", "model_name": "HE 85 A", "model_qualifier": "", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 56.8, "output_kw_max": 25.6, "final_year_of_manufacture": null, "raw": ["009756", "000026", "0", "2006/Jan/17 12:31", "Ravenheat", "Ravenheat", "HE 85 A", "", "", "2003", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "25.6", "25.6", "", "", "89.4", "80.8", "", "56.8", "", "2", "", "", "104", "1", "2", "60", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "0", "", "0005", "", "", "", "", "", "", "", "", "88.9", "100.0", "", "", "", "", "97.9"]} -{"pcdb_id": 9757, "brand_name": "Ravenheat", "model_name": "HE Primary A LPG", "model_qualifier": "", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 81.6, "comparative_hot_water_efficiency_pct": 59.6, "output_kw_max": 25.6, "final_year_of_manufacture": null, "raw": ["009757", "000026", "0", "2012/Mar/27 10:12", "Ravenheat", "Ravenheat", "HE Primary A LPG", "", "", "2003", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "11.7", "25.6", "", "", "89.2", "81.6", "", "59.6", "", "2", "0", "", "101", "1", "1", "60", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.9", "100.1", "", "", "", "", "98.4"]} -{"pcdb_id": 9758, "brand_name": "Ravenheat", "model_name": "HE Primary A", "model_qualifier": "", "winter_efficiency_pct": 87.2, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 25.6, "final_year_of_manufacture": null, "raw": ["009758", "000026", "0", "2012/Mar/27 10:12", "Ravenheat", "Ravenheat", "HE Primary A", "", "", "2003", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "11.7", "25.6", "", "", "87.2", "79.6", "", "58.2", "", "2", "", "", "101", "1", "1", "60", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "88.9", "98.0", "", "", "", "", "96.3"]} -{"pcdb_id": 9759, "brand_name": "Ravenheat", "model_name": "HE System A LPG", "model_qualifier": "", "winter_efficiency_pct": 90.6, "summer_efficiency_pct": 81.6, "comparative_hot_water_efficiency_pct": 59.6, "output_kw_max": 25.6, "final_year_of_manufacture": null, "raw": ["009759", "000026", "0", "2012/Mar/27 10:12", "Ravenheat", "Ravenheat", "HE System A LPG", "", "", "2003", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "25.6", "25.6", "", "", "90.6", "81.6", "", "59.6", "", "2", "0", "", "102", "1", "2", "60", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.9", "100.1", "", "", "", "", "98.4"]} -{"pcdb_id": 9760, "brand_name": "Ravenheat", "model_name": "HE System A", "model_qualifier": "", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 80.4, "comparative_hot_water_efficiency_pct": 58.7, "output_kw_max": 25.6, "final_year_of_manufacture": null, "raw": ["009760", "000026", "0", "2012/Mar/27 10:12", "Ravenheat", "Ravenheat", "HE System A", "", "", "2003", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "25.6", "25.6", "", "", "89.4", "80.4", "", "58.7", "", "2", "", "", "102", "1", "2", "60", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.9", "100.0", "", "", "", "", "97.9"]} -{"pcdb_id": 9761, "brand_name": "Ravenheat", "model_name": "HE System A T LPG", "model_qualifier": "", "winter_efficiency_pct": 90.6, "summer_efficiency_pct": 81.6, "comparative_hot_water_efficiency_pct": 59.6, "output_kw_max": 25.6, "final_year_of_manufacture": null, "raw": ["009761", "000026", "0", "2012/Mar/27 10:12", "Ravenheat", "Ravenheat", "HE System A T LPG", "", "", "2003", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "25.6", "25.6", "", "", "90.6", "81.6", "", "59.6", "", "2", "0", "", "102", "1", "2", "60", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.9", "100.1", "", "", "", "", "98.4"]} -{"pcdb_id": 9762, "brand_name": "Ravenheat", "model_name": "HE System A T", "model_qualifier": "", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 80.4, "comparative_hot_water_efficiency_pct": 58.7, "output_kw_max": 25.6, "final_year_of_manufacture": null, "raw": ["009762", "000026", "0", "2012/Mar/27 10:12", "Ravenheat", "Ravenheat", "HE System A T", "", "", "2003", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "25.6", "25.6", "", "", "89.4", "80.4", "", "58.7", "", "2", "", "", "102", "1", "2", "60", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.9", "100.0", "", "", "", "", "97.9"]} -{"pcdb_id": 9763, "brand_name": "NST", "model_name": "Sogno ELR", "model_qualifier": "8-30", "winter_efficiency_pct": 83.3, "summer_efficiency_pct": 72.6, "comparative_hot_water_efficiency_pct": 53.0, "output_kw_max": 30.06, "final_year_of_manufacture": null, "raw": ["009763", "000216", "0", "2012/Mar/27 10:12", "NST Nvovi Sistemi Termotecnici", "NST", "Sogno ELR", "8-30", "", "2001", "current", "2", "2", "1", "1", "0", "", "", "1", "3", "2", "30.06", "30.06", "", "", "83.3", "72.6", "", "53.0", "", "2", "1", "", "102", "1", "2", "185", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "87.2", "88.0", "", "", "", "", "87.8"]} -{"pcdb_id": 9764, "brand_name": "NST", "model_name": "Sogno ELR", "model_qualifier": "8-30", "winter_efficiency_pct": 83.5, "summer_efficiency_pct": 72.8, "comparative_hot_water_efficiency_pct": 53.2, "output_kw_max": 30.06, "final_year_of_manufacture": null, "raw": ["009764", "000216", "0", "2012/Mar/27 10:12", "NST Nvovi Sistemi Termotecnici", "NST", "Sogno ELR", "8-30", "", "2001", "current", "1", "2", "1", "1", "0", "", "", "1", "3", "2", "30.06", "30.06", "", "", "83.5", "72.8", "", "53.2", "", "2", "", "", "102", "1", "2", "185", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "85.3", "86.0", "", "", "", "", "85.9"]} -{"pcdb_id": 9765, "brand_name": "NST", "model_name": "Sogno ELR", "model_qualifier": "8-26", "winter_efficiency_pct": 83.3, "summer_efficiency_pct": 72.6, "comparative_hot_water_efficiency_pct": 53.0, "output_kw_max": 26.73, "final_year_of_manufacture": null, "raw": ["009765", "000216", "0", "2012/Mar/27 10:12", "NST Nvovi Sistemi Termotecnici", "NST", "Sogno ELR", "8-26", "", "2001", "current", "2", "2", "1", "1", "0", "", "", "1", "3", "2", "26.73", "26.73", "", "", "83.3", "72.6", "", "53.0", "", "2", "1", "", "102", "1", "2", "185", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "88.2", "87.9", "", "", "", "", "87.9"]} -{"pcdb_id": 9766, "brand_name": "NST", "model_name": "Sogno ELR", "model_qualifier": "8-26", "winter_efficiency_pct": 83.4, "summer_efficiency_pct": 72.7, "comparative_hot_water_efficiency_pct": 53.1, "output_kw_max": 26.73, "final_year_of_manufacture": null, "raw": ["009766", "000216", "0", "2012/Mar/27 10:12", "NST Nvovi Sistemi Termotecnici", "NST", "Sogno ELR", "8-26", "", "2001", "current", "1", "2", "1", "1", "0", "", "", "1", "3", "2", "26.73", "26.73", "", "", "83.4", "72.7", "", "53.1", "", "2", "", "", "102", "1", "2", "185", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "86.3", "86.0", "", "", "", "", "86.0"]} -{"pcdb_id": 9767, "brand_name": "NST", "model_name": "Sogno ELR", "model_qualifier": "8-22", "winter_efficiency_pct": 83.3, "summer_efficiency_pct": 72.6, "comparative_hot_water_efficiency_pct": 53.0, "output_kw_max": 22.42, "final_year_of_manufacture": null, "raw": ["009767", "000216", "0", "2012/Mar/27 10:12", "NST Nvovi Sistemi Termotecnici", "NST", "Sogno ELR", "8-22", "", "2001", "current", "2", "2", "1", "1", "0", "", "", "1", "3", "2", "22.42", "22.42", "", "", "83.3", "72.6", "", "53.0", "", "2", "1", "", "102", "1", "2", "185", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "88.2", "87.9", "", "", "", "", "87.9"]} -{"pcdb_id": 9768, "brand_name": "NST", "model_name": "Sogno ELR", "model_qualifier": "8-22", "winter_efficiency_pct": 83.4, "summer_efficiency_pct": 72.7, "comparative_hot_water_efficiency_pct": 53.1, "output_kw_max": 22.42, "final_year_of_manufacture": null, "raw": ["009768", "000216", "0", "2012/Mar/27 10:12", "NST Nvovi Sistemi Termotecnici", "NST", "Sogno ELR", "8-22", "", "2001", "current", "1", "2", "1", "1", "0", "", "", "1", "3", "2", "22.42", "22.42", "", "", "83.4", "72.7", "", "53.1", "", "2", "", "", "102", "1", "2", "185", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "86.3", "86.0", "", "", "", "", "86.0"]} -{"pcdb_id": 9769, "brand_name": "NST", "model_name": "Sono ELI", "model_qualifier": "8-30", "winter_efficiency_pct": 83.1, "summer_efficiency_pct": 73.0, "comparative_hot_water_efficiency_pct": 51.3, "output_kw_max": 30.06, "final_year_of_manufacture": null, "raw": ["009769", "000216", "0", "2006/Jan/17 12:31", "NST Nvovi Sistemi Termotecnici", "NST", "Sono ELI", "8-30", "", "2001", "current", "2", "2", "1", "2", "0", "", "", "1", "3", "2", "30.06", "30.06", "", "", "83.1", "73.0", "", "51.3", "", "2", "1", "", "104", "1", "2", "185", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "87.2", "88.0", "", "", "", "", "87.8"]} -{"pcdb_id": 9770, "brand_name": "NST", "model_name": "Sogno ELI", "model_qualifier": "8-30", "winter_efficiency_pct": 83.3, "summer_efficiency_pct": 73.2, "comparative_hot_water_efficiency_pct": 51.5, "output_kw_max": 30.06, "final_year_of_manufacture": null, "raw": ["009770", "000216", "0", "2006/Jan/17 12:31", "NST Nvovi Sistemi Termotecnici", "NST", "Sogno ELI", "8-30", "", "2001", "current", "1", "2", "1", "2", "0", "", "", "1", "3", "2", "30.06", "30.06", "", "", "83.3", "73.2", "", "51.5", "", "2", "", "", "104", "1", "2", "185", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "85.3", "86.0", "", "", "", "", "85.9"]} -{"pcdb_id": 9771, "brand_name": "NST", "model_name": "Sogno ELI", "model_qualifier": "8-26", "winter_efficiency_pct": 83.1, "summer_efficiency_pct": 73.0, "comparative_hot_water_efficiency_pct": 51.3, "output_kw_max": 26.73, "final_year_of_manufacture": null, "raw": ["009771", "000216", "0", "2006/Jan/17 12:31", "NST Nvovi Sistemi Termotecnici", "NST", "Sogno ELI", "8-26", "", "2001", "current", "2", "2", "1", "2", "0", "", "", "1", "3", "2", "26.73", "26.73", "", "", "83.1", "73.0", "", "51.3", "", "2", "1", "", "104", "1", "2", "185", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "88.2", "87.9", "", "", "", "", "87.9"]} -{"pcdb_id": 9772, "brand_name": "NST", "model_name": "Sogno ELI", "model_qualifier": "8-26", "winter_efficiency_pct": 83.2, "summer_efficiency_pct": 73.1, "comparative_hot_water_efficiency_pct": 51.4, "output_kw_max": 26.73, "final_year_of_manufacture": null, "raw": ["009772", "000216", "0", "2006/Jan/17 12:31", "NST Nvovi Sistemi Termotecnici", "NST", "Sogno ELI", "8-26", "", "2001", "current", "1", "2", "1", "2", "0", "", "", "1", "3", "2", "26.73", "26.73", "", "", "83.2", "73.1", "", "51.4", "", "2", "", "", "104", "1", "2", "185", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "86.3", "86.0", "", "", "", "", "86.0"]} -{"pcdb_id": 9773, "brand_name": "NST", "model_name": "Sogno ELI", "model_qualifier": "8-22", "winter_efficiency_pct": 83.1, "summer_efficiency_pct": 73.0, "comparative_hot_water_efficiency_pct": 51.3, "output_kw_max": 22.42, "final_year_of_manufacture": null, "raw": ["009773", "000216", "0", "2006/Jan/17 12:31", "NST Nvovi Sistemi Termotecnici", "NST", "Sogno ELI", "8-22", "", "2001", "current", "2", "2", "1", "2", "0", "", "", "1", "3", "2", "22.42", "22.42", "", "", "83.1", "73.0", "", "51.3", "", "2", "1", "", "104", "1", "2", "185", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "88.2", "87.9", "", "", "", "", "87.9"]} -{"pcdb_id": 9774, "brand_name": "NST", "model_name": "Sogno ELI", "model_qualifier": "8-22", "winter_efficiency_pct": 83.2, "summer_efficiency_pct": 73.1, "comparative_hot_water_efficiency_pct": 51.4, "output_kw_max": 22.42, "final_year_of_manufacture": null, "raw": ["009774", "000216", "0", "2006/Jan/17 12:31", "NST Nvovi Sistemi Termotecnici", "NST", "Sogno ELI", "8-22", "", "2001", "current", "1", "2", "1", "2", "0", "", "", "1", "3", "2", "22.42", "22.42", "", "", "83.2", "73.1", "", "51.4", "", "2", "", "", "104", "1", "2", "185", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "86.3", "86.0", "", "", "", "", "86.0"]} -{"pcdb_id": 9775, "brand_name": "Baxi", "model_name": "Combi", "model_qualifier": "Instant 80 e", "winter_efficiency_pct": 79.5, "summer_efficiency_pct": 69.4, "comparative_hot_water_efficiency_pct": 48.8, "output_kw_max": 24.0, "final_year_of_manufacture": 2005, "raw": ["009775", "000005", "0", "2006/Nov/21 10:07", "Baxi SpA", "Baxi", "Combi", "Instant 80 e", "GC no. 47-075-13", "2003", "2005", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "24.0", "24.0", "", "", "79.5", "69.4", "", "48.8", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.2", "79.2", "", "", "", "", "79.8"]} -{"pcdb_id": 9776, "brand_name": "Baxi Potterton", "model_name": "Baxi Bermuda", "model_qualifier": "Inset 3 50/5", "winter_efficiency_pct": 78.0, "summer_efficiency_pct": 67.3, "comparative_hot_water_efficiency_pct": 49.1, "output_kw_max": 14.65, "final_year_of_manufacture": 2005, "raw": ["009776", "000005", "0", "2012/Mar/27 10:12", "Baxi Potterton", "Baxi Potterton", "Baxi Bermuda", "Inset 3 50/5", "GC No. 44-075-07", "2003", "2005", "1", "4", "1", "1", "0", "", "", "1", "1", "1", "14.65", "14.65", "", "", "78.0", "67.3", "", "49.1", "", "2", "", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.6", "76.3", "", "", "", "", "77.3"]} -{"pcdb_id": 9777, "brand_name": "Baxi", "model_name": "Bermuda", "model_qualifier": "51/5", "winter_efficiency_pct": 79.0, "summer_efficiency_pct": 68.3, "comparative_hot_water_efficiency_pct": 49.9, "output_kw_max": 15.0, "final_year_of_manufacture": 2010, "raw": ["009777", "000005", "0", "2012/Mar/27 10:12", "Baxi Potterton", "Baxi", "Bermuda", "51/5", "GC No. 44-075-06", "2003", "2010", "1", "4", "1", "1", "0", "", "", "1", "1", "1", "15", "15", "", "", "79.0", "68.3", "", "49.9", "", "2", "", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "80.7", "79.3", "", "", "", "", "79.6"]} -{"pcdb_id": 9782, "brand_name": "Hermann Srl", "model_name": "Eura 32 SE", "model_qualifier": "", "winter_efficiency_pct": 80.2, "summer_efficiency_pct": 70.1, "comparative_hot_water_efficiency_pct": 49.3, "output_kw_max": 31.7, "final_year_of_manufacture": null, "raw": ["009782", "000234", "0", "2013/Jun/25 14:32", "Hermann Srl", "Hermann Srl", "Eura 32 SE", "", "", "2000", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "31.7", "31.7", "", "", "80.2", "70.1", "", "49.3", "", "2", "", "", "104", "1", "2", "185", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.7", "80.1", "", "", "", "", "80.6"]} -{"pcdb_id": 9783, "brand_name": "Hermann Srl", "model_name": "Euromini 24 SE", "model_qualifier": "", "winter_efficiency_pct": 80.8, "summer_efficiency_pct": 70.7, "comparative_hot_water_efficiency_pct": 49.7, "output_kw_max": 23.7, "final_year_of_manufacture": null, "raw": ["009783", "000234", "0", "2013/Jun/25 14:33", "Hermann Srl", "Hermann Srl", "Euromini 24 SE", "", "", "2003", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "23.7", "23.7", "", "", "80.8", "70.7", "", "49.7", "", "2", "", "", "104", "1", "2", "150", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "84.2", "81.2", "", "", "", "", "81.7"]} -{"pcdb_id": 9784, "brand_name": "Hermann Srl", "model_name": "Supermicra 24 SE", "model_qualifier": "", "winter_efficiency_pct": 79.6, "summer_efficiency_pct": 69.5, "comparative_hot_water_efficiency_pct": 48.9, "output_kw_max": 23.6, "final_year_of_manufacture": null, "raw": ["009784", "000234", "0", "2013/Jun/25 14:33", "Hermann Srl", "Hermann Srl", "Supermicra 24 SE", "", "", "2002", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "23.6", "23.6", "", "", "79.6", "69.5", "", "48.9", "", "2", "", "", "104", "1", "2", "150", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "83.0", "78.7", "", "", "", "", "79.6"]} -{"pcdb_id": 9785, "brand_name": "Hermann Srl", "model_name": "Supermicra 30 SE", "model_qualifier": "", "winter_efficiency_pct": 80.9, "summer_efficiency_pct": 70.8, "comparative_hot_water_efficiency_pct": 49.8, "output_kw_max": 29.5, "final_year_of_manufacture": null, "raw": ["009785", "000234", "0", "2013/Jun/25 14:33", "Hermann Srl", "Hermann Srl", "Supermicra 30 SE", "", "", "2002", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "29.5", "29.5", "", "", "80.9", "70.8", "", "49.8", "", "2", "", "", "104", "1", "2", "180", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "84.2", "81.4", "", "", "", "", "81.9"]} -{"pcdb_id": 9788, "brand_name": "Sile SpA", "model_name": "Condensa 32 R", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 56.2, "output_kw_max": 30.0, "final_year_of_manufacture": null, "raw": ["009788", "000221", "0", "2008/Sep/29 16:02", "Sile SpA", "Sile SpA", "Condensa 32 R", "", "", "2003", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "30.00", "30.00", "", "", "88.4", "79.8", "", "56.2", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.2", "97.8", "", "", "", "", "96.0"]} -{"pcdb_id": 9789, "brand_name": "Sile SpA", "model_name": "Condensa 50 R", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 56.2, "output_kw_max": 48.0, "final_year_of_manufacture": null, "raw": ["009789", "000221", "0", "2008/Sep/29 16:03", "Sile SpA", "Sile SpA", "Condensa 50 R", "", "", "2003", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "48.00", "48.00", "", "", "88.4", "79.8", "", "56.2", "", "2", "", "", "104", "1", "2", "140", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.2", "97.8", "", "", "", "", "96.0"]} -{"pcdb_id": 9790, "brand_name": "Sile SpA", "model_name": "Condensa 50 N", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 48.0, "final_year_of_manufacture": null, "raw": ["009790", "000221", "0", "2012/Mar/27 10:12", "Sile SpA", "Sile SpA", "Condensa 50 N", "", "", "2003", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "48.00", "48.00", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "140", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.2", "97.8", "", "", "", "", "96.0"]} -{"pcdb_id": 9791, "brand_name": "Sile SpA", "model_name": "Condensa 50 N3V", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 48.0, "final_year_of_manufacture": null, "raw": ["009791", "000221", "0", "2012/Mar/27 10:12", "Sile SpA", "Sile SpA", "Condensa 50 N3V", "", "", "2003", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "48.00", "48.00", "", "", "88.5", "79.5", "", "58.1", "", "2", "", "", "102", "1", "2", "140", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.7", "97.8", "", "", "", "", "96.1"]} -{"pcdb_id": 9792, "brand_name": "Sile SpA", "model_name": "Condensa 50 Maxi", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 81.2, "comparative_hot_water_efficiency_pct": 35.4, "output_kw_max": 48.0, "final_year_of_manufacture": null, "raw": ["009792", "000221", "0", "2024/Jan/31 10:17", "Sile SpA", "Sile SpA", "Condensa 50 Maxi", "", "", "2003", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "48.0", "48.0", "", "", "88.5", "81.2", "", "35.4", "", "2", "", "", "106", "1", "2", "140", "0", "2", "1", "0", "120", "0", "15", "4", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.7", "97.8", "", "", "", "", "96.1"]} -{"pcdb_id": 9793, "brand_name": "Geminox", "model_name": "THI 10-50 C", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 52.6, "final_year_of_manufacture": null, "raw": ["009793", "000212", "0", "2012/Mar/27 10:12", "Geminox", "Geminox", "THI 10-50 C", "", "", "2004", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "52.6", "52.6", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "53", "9.2", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.7", "97.0", "", "", "", "", "95.3"]} -{"pcdb_id": 9794, "brand_name": "Geminox", "model_name": "THI 5-25 M75", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 48.5, "output_kw_max": 23.9, "final_year_of_manufacture": null, "raw": ["009794", "000212", "0", "2024/Jan/31 10:17", "Geminox", "Geminox", "THI 5-25 M75", "", "", "2003", "current", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "23.9", "23.9", "", "", "88.3", "81.0", "", "48.5", "", "2", "", "", "106", "1", "2", "23", "9.2", "1", "1", "0", "83", "0", "50", "2", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "97.8", "", "", "", "", "95.9"]} -{"pcdb_id": 9795, "brand_name": "Geminox", "model_name": "THI 2-13 M75 V", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 54.3, "output_kw_max": 13.5, "final_year_of_manufacture": null, "raw": ["009795", "000212", "0", "2024/Jan/31 10:17", "Geminox", "Geminox", "THI 2-13 M75 V", "", "", "2004", "current", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "13.5", "13.5", "", "", "88.3", "81.0", "", "54.3", "", "2", "", "", "106", "1", "2", "23", "9.2", "1", "1", "0", "83", "0", "50", "2", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "97.8", "", "", "", "", "95.9"]} -{"pcdb_id": 9796, "brand_name": "Geminox", "model_name": "THI 5-25S", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 49.3, "output_kw_max": 23.9, "final_year_of_manufacture": null, "raw": ["009796", "000212", "0", "2024/Jan/31 10:17", "Geminox", "Geminox", "THI 5-25S", "", "", "2004", "current", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "23.9", "23.9", "", "", "88.3", "81.0", "", "49.3", "", "2", "", "", "106", "1", "2", "23", "9.2", "1", "1", "0", "24.5", "0", "35", "2", "60", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "97.8", "", "", "", "", "95.9"]} -{"pcdb_id": 9797, "brand_name": "Geminox", "model_name": "THI 5-25 SEP", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 62.2, "output_kw_max": 23.9, "final_year_of_manufacture": null, "raw": ["009797", "000212", "0", "2006/Mar/29 12:43", "Geminox", "Geminox", "THI 5-25 SEP", "", "", "2003", "current", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "23.9", "23.9", "", "", "88.3", "79.7", "", "62.2", "", "2", "", "", "104", "1", "2", "23", "9.2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "", "0005", "", "", "", "", "", "", "", "", "87.8", "97.8", "", "", "", "", "95.9"]} -{"pcdb_id": 9798, "brand_name": "Geminox", "model_name": "THI 5-25 C", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 23.9, "final_year_of_manufacture": null, "raw": ["009798", "000212", "0", "2012/Mar/27 10:12", "Geminox", "Geminox", "THI 5-25 C", "", "", "2004", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "23.9", "23.9", "", "", "88.3", "79.3", "", "58.0", "", "2", "", "", "102", "1", "2", "23", "9.2", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "97.8", "", "", "", "", "95.9"]} -{"pcdb_id": 9799, "brand_name": "Geminox", "model_name": "THI 2-13 C", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 13.5, "final_year_of_manufacture": null, "raw": ["009799", "000212", "0", "2012/Mar/27 10:12", "Geminox", "Geminox", "THI 2-13 C", "", "", "2003", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "13.5", "13.5", "", "", "88.3", "79.3", "", "58.0", "", "2", "", "", "102", "1", "2", "23", "9.2", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "97.8", "", "", "", "", "95.9"]} -{"pcdb_id": 9800, "brand_name": "Geminox", "model_name": "THI 0.9-9 C", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 9.1, "final_year_of_manufacture": null, "raw": ["009800", "000212", "0", "2012/Mar/27 10:12", "Geminox", "Geminox", "THI 0.9-9 C", "", "", "2003", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "9.1", "9.1", "", "", "88.3", "79.3", "", "58.0", "", "2", "", "", "102", "1", "2", "23", "9.2", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "97.8", "", "", "", "", "95.9"]} -{"pcdb_id": 9801, "brand_name": "Ideal", "model_name": "Mini C32", "model_qualifier": "32kW Combi Boiler", "winter_efficiency_pct": 79.2, "summer_efficiency_pct": 69.1, "comparative_hot_water_efficiency_pct": 48.6, "output_kw_max": 32.0, "final_year_of_manufacture": 2004, "raw": ["009801", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "Mini C32", "32kW Combi Boiler", "0694BM3420", "2003", "2004", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "32.0", "32.0", "", "", "79.2", "69.1", "", "48.6", "", "2", "", "", "104", "1", "2", "180", "7", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.0", "78.7", "", "", "", "", "79.4"]} -{"pcdb_id": 9802, "brand_name": "Alpha", "model_name": "C27", "model_qualifier": "", "winter_efficiency_pct": 79.8, "summer_efficiency_pct": 69.7, "comparative_hot_water_efficiency_pct": 49.0, "output_kw_max": 27.0, "final_year_of_manufacture": 2005, "raw": ["009802", "000001", "0", "2006/Jan/17 12:31", "Alpha Therm", "Alpha", "C27", "", "", "2003", "2005", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "27", "27", "", "", "79.8", "69.7", "", "49.0", "", "2", "", "", "104", "1", "2", "170", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.8", "80.3", "", "", "", "", "80.6"]} -{"pcdb_id": 9803, "brand_name": "Alpha", "model_name": "C23", "model_qualifier": "", "winter_efficiency_pct": 79.8, "summer_efficiency_pct": 69.7, "comparative_hot_water_efficiency_pct": 49.0, "output_kw_max": 23.3, "final_year_of_manufacture": 2005, "raw": ["009803", "000001", "0", "2011/Sep/06 13:07", "Alpha Therm", "Alpha", "C23", "", "", "2003", "2005", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "23.3", "23.3", "", "", "79.8", "69.7", "", "49.0", "", "2", "", "", "104", "1", "2", "170", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.6", "80.5", "", "", "", "", "80.7"]} -{"pcdb_id": 9804, "brand_name": "IRSAP", "model_name": "Ecogreen CWAI 24", "model_qualifier": "M", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 55.8, "output_kw_max": 24.12, "final_year_of_manufacture": null, "raw": ["009804", "000235", "0", "2006/Jan/17 12:31", "IRSAP", "IRSAP", "Ecogreen CWAI 24", "M", "", "2002", "current", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "24.12", "24.12", "", "", "87.9", "79.3", "", "55.8", "", "2", "", "", "104", "1", "2", "37.0", "8.3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.5", "96.4", "", "", "", "", "94.9"]} -{"pcdb_id": 9805, "brand_name": "IRSAP", "model_name": "CWAI 24", "model_qualifier": "M", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 55.8, "output_kw_max": 24.12, "final_year_of_manufacture": null, "raw": ["009805", "000235", "0", "2006/Jan/17 12:31", "IRSAP", "IRSAP", "CWAI 24", "M", "", "2002", "current", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "24.12", "24.12", "", "", "87.9", "79.3", "", "55.8", "", "2", "", "", "104", "1", "2", "37.0", "8.3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.5", "96.4", "", "", "", "", "94.9"]} -{"pcdb_id": 9806, "brand_name": "IRSAP", "model_name": "Ecogreen CWAI 32", "model_qualifier": "M", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 56.0, "output_kw_max": 32.02, "final_year_of_manufacture": null, "raw": ["009806", "000235", "0", "2006/Jan/17 12:31", "IRSAP", "IRSAP", "Ecogreen CWAI 32", "M", "", "2002", "current", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "32.02", "32.02", "", "", "88.2", "79.6", "", "56.0", "", "2", "", "", "104", "1", "2", "47", "8.3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.4", "97.2", "", "", "", "", "95.5"]} -{"pcdb_id": 9807, "brand_name": "IRSAP", "model_name": "CWAI 32", "model_qualifier": "M", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 56.0, "output_kw_max": 32.02, "final_year_of_manufacture": null, "raw": ["009807", "000235", "0", "2006/Jan/17 12:31", "IRSAP", "IRSAP", "CWAI 32", "M", "", "2002", "current", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "32.02", "32.02", "", "", "88.2", "79.6", "", "56.0", "", "2", "", "", "104", "1", "2", "47", "8.3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.4", "97.2", "", "", "", "", "95.5"]} -{"pcdb_id": 9808, "brand_name": "IRSAP", "model_name": "Ecogreen CWAS 24", "model_qualifier": "M", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 80.6, "comparative_hot_water_efficiency_pct": 46.5, "output_kw_max": 24.12, "final_year_of_manufacture": null, "raw": ["009808", "000235", "0", "2024/Jan/31 10:17", "IRSAP", "IRSAP", "Ecogreen CWAS 24", "M", "", "2002", "current", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "24.12", "24.12", "", "", "87.9", "80.6", "", "46.5", "", "2", "", "", "106", "1", "2", "37.0", "8.3", "2", "1", "0", "55", "0", "20", "2", "55", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.5", "96.4", "", "", "", "", "94.9"]} -{"pcdb_id": 9809, "brand_name": "IRSAP", "model_name": "CWAS 24", "model_qualifier": "M", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 80.6, "comparative_hot_water_efficiency_pct": 46.5, "output_kw_max": 24.12, "final_year_of_manufacture": null, "raw": ["009809", "000235", "0", "2024/Jan/31 10:17", "IRSAP", "IRSAP", "CWAS 24", "M", "", "2002", "current", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "24.12", "24.12", "", "", "87.9", "80.6", "", "46.5", "", "2", "", "", "106", "1", "2", "37.0", "8.3", "2", "1", "0", "55", "0", "20", "2", "55", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.5", "96.4", "", "", "", "", "94.9"]} -{"pcdb_id": 9810, "brand_name": "IRSAP", "model_name": "Ecogreen CWAS 32", "model_qualifier": "M", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 80.9, "comparative_hot_water_efficiency_pct": 46.6, "output_kw_max": 32.02, "final_year_of_manufacture": null, "raw": ["009810", "000235", "0", "2024/Jan/31 10:17", "IRSAP", "IRSAP", "Ecogreen CWAS 32", "M", "", "2002", "current", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "32.02", "32.02", "", "", "88.2", "80.9", "", "46.6", "", "2", "", "", "106", "1", "2", "47", "8.3", "2", "1", "0", "55", "0", "20", "2", "55", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.4", "97.2", "", "", "", "", "95.5"]} -{"pcdb_id": 9811, "brand_name": "IRSAP", "model_name": "CWAS 32", "model_qualifier": "M", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 80.9, "comparative_hot_water_efficiency_pct": 46.6, "output_kw_max": 32.02, "final_year_of_manufacture": null, "raw": ["009811", "000235", "0", "2024/Jan/31 10:17", "IRSAP", "IRSAP", "CWAS 32", "M", "", "2002", "current", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "32.02", "32.02", "", "", "88.2", "80.9", "", "46.6", "", "2", "", "", "106", "1", "2", "47", "8.3", "2", "1", "0", "55", "0", "20", "2", "55", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.4", "97.2", "", "", "", "", "95.5"]} -{"pcdb_id": 9812, "brand_name": "Vokera", "model_name": "Syntesi", "model_qualifier": "35 LPG", "winter_efficiency_pct": 89.3, "summer_efficiency_pct": 80.7, "comparative_hot_water_efficiency_pct": 56.7, "output_kw_max": 33.9, "final_year_of_manufacture": 2010, "raw": ["009812", "000011", "0", "2010/Oct/21 11:07", "Vokera", "Vokera", "Syntesi", "35 LPG", "4709451", "2003", "2010", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "33.9", "33.9", "", "", "89.3", "80.7", "", "56.7", "", "2", "0", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.7", "97.2", "", "", "", "", "95.7"]} -{"pcdb_id": 9813, "brand_name": "Vokera", "model_name": "Syntesi", "model_qualifier": "35", "winter_efficiency_pct": 86.4, "summer_efficiency_pct": 77.8, "comparative_hot_water_efficiency_pct": 54.7, "output_kw_max": 33.9, "final_year_of_manufacture": 2010, "raw": ["009813", "000011", "0", "2010/Oct/21 11:08", "Vokera", "Vokera", "Syntesi", "35", "470945", "2003", "2010", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "33.9", "33.9", "", "", "86.4", "77.8", "", "54.7", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.3", "93.1", "", "", "", "", "92.0"]} -{"pcdb_id": 9814, "brand_name": "Vokera", "model_name": "Syntesi", "model_qualifier": "29 LPG", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 56.2, "output_kw_max": 28.0, "final_year_of_manufacture": 2010, "raw": ["009814", "000011", "0", "2010/Oct/21 11:08", "Vokera", "Vokera", "Syntesi", "29 LPG", "4709449", "2003", "2010", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "28.0", "28.0", "", "", "88.6", "80.0", "", "56.2", "", "2", "0", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.5", "95.4", "", "", "", "", "94.3"]} -{"pcdb_id": 9815, "brand_name": "Vokera", "model_name": "Syntesi", "model_qualifier": "29", "winter_efficiency_pct": 86.0, "summer_efficiency_pct": 77.4, "comparative_hot_water_efficiency_pct": 54.4, "output_kw_max": 28.0, "final_year_of_manufacture": 2010, "raw": ["009815", "000011", "0", "2010/Oct/21 11:08", "Vokera", "Vokera", "Syntesi", "29", "4709448", "2003", "2010", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28.0", "28.0", "", "", "86.0", "77.4", "", "54.4", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.0", "92.1", "", "", "", "", "91.1"]} -{"pcdb_id": 9816, "brand_name": "Vokera", "model_name": "Syntesi", "model_qualifier": "25 LPG", "winter_efficiency_pct": 89.5, "summer_efficiency_pct": 80.9, "comparative_hot_water_efficiency_pct": 56.9, "output_kw_max": 24.1, "final_year_of_manufacture": 2010, "raw": ["009816", "000011", "0", "2010/Oct/21 11:08", "Vokera", "Vokera", "Syntesi", "25 LPG", "4709447", "2003", "2010", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24.1", "24.1", "", "", "89.5", "80.9", "", "56.9", "", "2", "0", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.2", "97.6", "", "", "", "", "96.2"]} -{"pcdb_id": 9817, "brand_name": "Vokera", "model_name": "Syntesi", "model_qualifier": "25", "winter_efficiency_pct": 86.0, "summer_efficiency_pct": 77.4, "comparative_hot_water_efficiency_pct": 54.4, "output_kw_max": 24.1, "final_year_of_manufacture": 2010, "raw": ["009817", "000011", "0", "2010/Oct/21 11:08", "Vokera", "Vokera", "Syntesi", "25", "4709446", "2003", "2010", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.1", "24.1", "", "", "86.0", "77.4", "", "54.4", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "86.8", "92.2", "", "", "", "", "91.1"]} -{"pcdb_id": 9818, "brand_name": "Vokera", "model_name": "Synergy", "model_qualifier": "29 LPG", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 28.0, "final_year_of_manufacture": 2010, "raw": ["009818", "000011", "0", "2012/Mar/27 10:12", "Vokera", "Vokera", "Synergy", "29 LPG", "4109428", "2003", "2010", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "28.0", "28.0", "", "", "88.6", "79.6", "", "58.1", "", "2", "0", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.5", "95.4", "", "", "", "", "94.3"]} -{"pcdb_id": 9819, "brand_name": "Vokera", "model_name": "Synergy", "model_qualifier": "29", "winter_efficiency_pct": 86.0, "summer_efficiency_pct": 77.0, "comparative_hot_water_efficiency_pct": 56.2, "output_kw_max": 28.0, "final_year_of_manufacture": 2010, "raw": ["009819", "000011", "0", "2012/Mar/27 10:12", "Vokera", "Vokera", "Synergy", "29", "4109427", "2003", "2010", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "28.0", "28.0", "", "", "86.0", "77.0", "", "56.2", "", "2", "", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.0", "92.1", "", "", "", "", "91.1"]} -{"pcdb_id": 9825, "brand_name": "Atlantic 2000", "model_name": "R22/22", "model_qualifier": "Oil", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 80.4, "comparative_hot_water_efficiency_pct": 58.7, "output_kw_max": 22.0, "final_year_of_manufacture": null, "raw": ["009825", "000003", "0", "2023/Apr/27 08:50", "RYLL HEIZUNGS GMBH", "Atlantic 2000", "R22/22", "Oil", "", "2000", "obsolete", "4", "1", "1", "1", "0", "", "", "2", "1", "2", "15", "22.0", "", "", "88.2", "80.4", "", "58.7", "", "2", "", "", "201", "1", "1", "273", "15", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "95.0", "93.5", "", "", "", "", "93.8"]} -{"pcdb_id": 9826, "brand_name": "Atlantic 2000", "model_name": "R22/40", "model_qualifier": "Oil", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 58.8, "output_kw_max": 40.0, "final_year_of_manufacture": null, "raw": ["009826", "000003", "0", "2023/Apr/27 08:50", "RYLL HEIZUNGS GMBH", "Atlantic 2000", "R22/40", "Oil", "2297E 06030255", "2000", "obsolete", "4", "1", "1", "1", "0", "", "", "2", "1", "2", "28", "40", "", "", "88.3", "80.5", "", "58.8", "", "2", "", "", "201", "1", "1", "375", "15", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "95.3", "93.7", "", "", "", "", "94.0"]} -{"pcdb_id": 9830, "brand_name": "Keston", "model_name": "C", "model_qualifier": "40P", "winter_efficiency_pct": 89.6, "summer_efficiency_pct": 80.6, "comparative_hot_water_efficiency_pct": 58.9, "output_kw_max": 39.1, "final_year_of_manufacture": null, "raw": ["009830", "000022", "0", "2012/Mar/27 10:12", "Keston Boilers", "Keston", "C", "40P", "41-930-08", "2002", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "39.1", "39.1", "", "", "89.6", "80.6", "", "58.9", "", "2", "1", "", "102", "1", "2", "260", "8", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.4", "100.2", "", "", "", "", "98.3"]} -{"pcdb_id": 9831, "brand_name": "Keston", "model_name": "C", "model_qualifier": "55P", "winter_efficiency_pct": 90.1, "summer_efficiency_pct": 81.1, "comparative_hot_water_efficiency_pct": 59.2, "output_kw_max": 48.2, "final_year_of_manufacture": null, "raw": ["009831", "000022", "0", "2012/Mar/27 10:12", "Keston Boilers", "Keston", "C", "55P", "41-930-10", "2002", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "48.2", "48.2", "", "", "90.1", "81.1", "", "59.2", "", "2", "1", "", "102", "1", "2", "260", "8", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.9", "101.7", "", "", "", "", "99.4"]} -{"pcdb_id": 9832, "brand_name": "Halstead", "model_name": "Finest Platinum", "model_qualifier": "", "winter_efficiency_pct": 79.6, "summer_efficiency_pct": 69.5, "comparative_hot_water_efficiency_pct": 54.2, "output_kw_max": 24.9, "final_year_of_manufacture": null, "raw": ["009832", "000019", "0", "2006/Jan/17 12:31", "Halstead Boilers", "Halstead", "Finest Platinum", "", "", "2003", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "24.9", "24.9", "", "", "79.6", "69.5", "", "54.2", "", "2", "", "", "104", "1", "2", "190", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "", "0004", "", "", "", "", "", "", "", "", "81.5", "80.1", "", "", "", "", "80.4"]} -{"pcdb_id": 9833, "brand_name": "Mistral", "model_name": "CKUT2 - 7090", "model_qualifier": "Kitchen Utility", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 26.3, "final_year_of_manufacture": null, "raw": ["009833", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "CKUT2 - 7090", "Kitchen Utility", "", "2003", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "20.5", "26.3", "", "", "87.9", "80.1", "", "58.5", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.4", "94.6", "", "", "", "", "93.8"]} -{"pcdb_id": 9834, "brand_name": "Mistral", "model_name": "CKUT1 - 5070", "model_qualifier": "Kitchen Utility", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 20.5, "final_year_of_manufacture": null, "raw": ["009834", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "CKUT1 - 5070", "Kitchen Utility", "", "2003", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "14.6", "20.5", "", "", "87.9", "80.1", "", "58.5", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.4", "94.6", "", "", "", "", "93.8"]} -{"pcdb_id": 9835, "brand_name": "Mistral", "model_name": "CC2 - 7090", "model_qualifier": "Condensing Combi", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 81.8, "comparative_hot_water_efficiency_pct": 49.2, "output_kw_max": 26.3, "final_year_of_manufacture": null, "raw": ["009835", "000056", "0", "2024/Jan/31 10:17", "Mistral Boilers", "Mistral", "CC2 - 7090", "Condensing Combi", "", "2003", "current", "4", "1", "1", "2", "0", "", "", "2", "3", "1", "20.5", "26.3", "", "", "87.9", "81.8", "", "49.2", "", "2", "", "", "203", "1", "1", "", "", "2", "", "0", "60", "0", "25", "3", "75", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.4", "94.6", "", "", "", "", "93.8"]} -{"pcdb_id": 9836, "brand_name": "Mistral", "model_name": "CC1 - 5070", "model_qualifier": "Condensing Combi", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 81.8, "comparative_hot_water_efficiency_pct": 49.2, "output_kw_max": 20.5, "final_year_of_manufacture": null, "raw": ["009836", "000056", "0", "2024/Jan/31 10:17", "Mistral Boilers", "Mistral", "CC1 - 5070", "Condensing Combi", "", "2003", "current", "4", "1", "1", "2", "0", "", "", "2", "3", "1", "14.6", "20.5", "", "", "87.9", "81.8", "", "49.2", "", "2", "", "", "203", "1", "1", "", "", "2", "", "0", "60", "0", "25", "3", "75", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.4", "94.6", "", "", "", "", "93.8"]} -{"pcdb_id": 9837, "brand_name": "Mistral", "model_name": "CK2 - 7090", "model_qualifier": "Kitchen", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 26.3, "final_year_of_manufacture": null, "raw": ["009837", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "CK2 - 7090", "Kitchen", "", "2003", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "20.5", "26.3", "", "", "87.9", "80.1", "", "58.5", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.4", "94.6", "", "", "", "", "93.8"]} -{"pcdb_id": 9838, "brand_name": "Mistral", "model_name": "CK1 - 5070", "model_qualifier": "Kitchen", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 20.5, "final_year_of_manufacture": null, "raw": ["009838", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "CK1 - 5070", "Kitchen", "", "2003", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "14.6", "20.5", "", "", "87.9", "80.1", "", "58.5", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.4", "94.6", "", "", "", "", "93.8"]} -{"pcdb_id": 9839, "brand_name": "Mistral", "model_name": "CS2 - 7090", "model_qualifier": "Sealed System", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 26.3, "final_year_of_manufacture": null, "raw": ["009839", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "CS2 - 7090", "Sealed System", "", "2003", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "20.5", "26.3", "", "", "87.9", "80.1", "", "58.5", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.4", "94.6", "", "", "", "", "93.8"]} -{"pcdb_id": 9840, "brand_name": "Mistral", "model_name": "CS1 - 5070", "model_qualifier": "Sealed System", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 20.5, "final_year_of_manufacture": null, "raw": ["009840", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "CS1 - 5070", "Sealed System", "", "2003", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "14.6", "20.5", "", "", "87.9", "80.1", "", "58.5", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.4", "94.6", "", "", "", "", "93.8"]} -{"pcdb_id": 9841, "brand_name": "Mistral", "model_name": "CBH - 7090", "model_qualifier": "Boiler House", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 26.3, "final_year_of_manufacture": null, "raw": ["009841", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "CBH - 7090", "Boiler House", "", "2003", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "20.5", "26.3", "", "", "87.9", "80.1", "", "58.5", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.4", "94.6", "", "", "", "", "93.8"]} -{"pcdb_id": 9842, "brand_name": "Mistral", "model_name": "CBH - 5070", "model_qualifier": "Boiler House", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 20.5, "final_year_of_manufacture": null, "raw": ["009842", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "CBH - 5070", "Boiler House", "", "2003", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "14.6", "20.5", "", "", "87.9", "80.1", "", "58.5", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.4", "94.6", "", "", "", "", "93.8"]} -{"pcdb_id": 9843, "brand_name": "Mistral", "model_name": "COD - 7090", "model_qualifier": "Outdoor Model", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 26.3, "final_year_of_manufacture": null, "raw": ["009843", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "COD - 7090", "Outdoor Model", "", "2003", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "20.5", "26.3", "", "", "87.9", "80.1", "", "58.5", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.4", "94.6", "", "", "", "", "93.8"]} -{"pcdb_id": 9844, "brand_name": "Mistral", "model_name": "COD - 5070", "model_qualifier": "Outdoor Model", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 20.5, "final_year_of_manufacture": null, "raw": ["009844", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "COD - 5070", "Outdoor Model", "", "2003", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "14.6", "20.5", "", "", "87.9", "80.1", "", "58.5", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.4", "94.6", "", "", "", "", "93.8"]} -{"pcdb_id": 9845, "brand_name": "Mistral", "model_name": "COD - SS - 7090", "model_qualifier": "Outdoor Sealed System", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 26.3, "final_year_of_manufacture": null, "raw": ["009845", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "COD - SS - 7090", "Outdoor Sealed System", "", "2003", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "20.5", "26.3", "", "", "87.9", "80.1", "", "58.5", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.4", "94.6", "", "", "", "", "93.8"]} -{"pcdb_id": 9846, "brand_name": "Mistral", "model_name": "COD - SS - 5070", "model_qualifier": "Outdoor Sealed System", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 20.5, "final_year_of_manufacture": null, "raw": ["009846", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "COD - SS - 5070", "Outdoor Sealed System", "", "2003", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "14.6", "20.5", "", "", "87.9", "80.1", "", "58.5", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.4", "94.6", "", "", "", "", "93.8"]} -{"pcdb_id": 9847, "brand_name": "Mistral", "model_name": "COD - C - 7090", "model_qualifier": "Outdoor Combi", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 81.8, "comparative_hot_water_efficiency_pct": 49.2, "output_kw_max": 26.3, "final_year_of_manufacture": null, "raw": ["009847", "000056", "0", "2024/Jan/31 10:17", "Mistral Boilers", "Mistral", "COD - C - 7090", "Outdoor Combi", "", "2003", "current", "4", "1", "1", "2", "0", "", "", "2", "3", "1", "20.5", "26.3", "", "", "87.9", "81.8", "", "49.2", "", "2", "", "", "203", "1", "1", "", "", "2", "", "0", "60", "0", "25", "3", "75", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.4", "94.6", "", "", "", "", "93.8"]} -{"pcdb_id": 9848, "brand_name": "Mistral", "model_name": "COD - C - 5070", "model_qualifier": "Outdoor Combi", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 81.8, "comparative_hot_water_efficiency_pct": 49.2, "output_kw_max": 20.5, "final_year_of_manufacture": null, "raw": ["009848", "000056", "0", "2024/Jan/31 10:17", "Mistral Boilers", "Mistral", "COD - C - 5070", "Outdoor Combi", "", "2003", "current", "4", "1", "1", "2", "0", "", "", "2", "3", "1", "14.6", "20.5", "", "", "87.9", "81.8", "", "49.2", "", "2", "", "", "203", "1", "1", "", "", "2", "", "0", "60", "0", "25", "3", "75", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.4", "94.6", "", "", "", "", "93.8"]} -{"pcdb_id": 9849, "brand_name": "Worcester", "model_name": "Danesmoor FS", "model_qualifier": "12-18", "winter_efficiency_pct": 85.8, "summer_efficiency_pct": 74.1, "comparative_hot_water_efficiency_pct": 54.1, "output_kw_max": 18.0, "final_year_of_manufacture": 2008, "raw": ["009849", "000035", "0", "2020/Sep/04 08:06", "Worcester Heat Systems", "Worcester", "Danesmoor FS", "12-18", "", "2003", "2008", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "12", "18", "", "", "85.8", "74.1", "", "54.1", "", "2", "", "", "201", "1", "1", "140", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.7", "85.4", "", "", "", "", "85.6"]} -{"pcdb_id": 9850, "brand_name": "Worcester", "model_name": "Danesmoor FS", "model_qualifier": "18-25", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 25.0, "final_year_of_manufacture": 2008, "raw": ["009850", "000035", "0", "2020/Sep/04 08:06", "Worcester Heat Systems", "Worcester", "Danesmoor FS", "18-25", "", "2003", "2008", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "18", "25", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "140", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.8", "87.7", "", "", "", "", "87.7"]} -{"pcdb_id": 9851, "brand_name": "Halstead", "model_name": "Finest Platinum", "model_qualifier": "", "winter_efficiency_pct": 81.4, "summer_efficiency_pct": 71.3, "comparative_hot_water_efficiency_pct": 50.1, "output_kw_max": 24.9, "final_year_of_manufacture": null, "raw": ["009851", "000019", "0", "2006/Jan/17 12:31", "Halstead Boilers", "Halstead", "Finest Platinum", "", "", "2003", "current", "2", "2", "1", "2", "0", "", "", "1", "2", "2", "24.9", "24.9", "", "", "81.4", "71.3", "", "50.1", "", "2", "1", "", "104", "1", "2", "190", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "83.3", "81.9", "", "", "", "", "82.1"]} -{"pcdb_id": 9852, "brand_name": "Glow-worm", "model_name": "38hxi", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 38.0, "final_year_of_manufacture": null, "raw": ["009852", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "38hxi", "", "GC 47-047-71", "2003", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "38.00", "38.00", "", "", "88.5", "79.5", "", "58.1", "", "2", "", "", "102", "1", "2", "60", "15", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0085", "", "", "", "", "", "", "", "", "89.3", "97.5", "", "", "", "", "95.9"]} -{"pcdb_id": 9853, "brand_name": "Ariston", "model_name": "Microcombi 27 MFFI", "model_qualifier": "Micro Combi Series", "winter_efficiency_pct": 80.3, "summer_efficiency_pct": 70.2, "comparative_hot_water_efficiency_pct": 49.3, "output_kw_max": 27.0, "final_year_of_manufacture": 2007, "raw": ["009853", "000080", "0", "2007/Jun/18 09:32", "Merloni TermoSanitari SpA", "Ariston", "Microcombi 27 MFFI", "Micro Combi Series", "GC No. 47-116-24", "2003", "2007", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "27", "27", "", "", "80.3", "70.2", "", "49.3", "", "2", "", "", "104", "1", "2", "130", "7", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.9", "80.0", "", "", "", "", "80.6"]} -{"pcdb_id": 9854, "brand_name": "Ariston", "model_name": "Microcombi 27 MFFI", "model_qualifier": "MK2", "winter_efficiency_pct": 82.1, "summer_efficiency_pct": 72.0, "comparative_hot_water_efficiency_pct": 50.6, "output_kw_max": 27.0, "final_year_of_manufacture": 2007, "raw": ["009854", "000080", "0", "2007/Sep/12 15:12", "Merloni TermoSanitari SpA", "Ariston", "Microcombi 27 MFFI", "MK2", "GC No. 47-116-24", "2003", "2007", "2", "2", "1", "2", "0", "", "", "1", "2", "2", "27", "27", "", "", "82.1", "72.0", "", "50.6", "", "2", "1", "", "104", "1", "2", "130", "7", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "84.7", "81.8", "", "", "", "", "82.3"]} -{"pcdb_id": 9859, "brand_name": "Malvern", "model_name": "Dbi Combi", "model_qualifier": "NG", "winter_efficiency_pct": 85.6, "summer_efficiency_pct": 77.0, "comparative_hot_water_efficiency_pct": 54.2, "output_kw_max": 23.5, "final_year_of_manufacture": null, "raw": ["009859", "000023", "0", "2006/Jan/17 12:31", "Malvern Boilers", "Malvern", "Dbi Combi", "NG", "", "2003", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "23.5", "23.5", "", "", "85.6", "77.0", "", "54.2", "", "2", "", "", "104", "1", "2", "120", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.2", "91.1", "", "", "", "", "90.4"]} -{"pcdb_id": 9860, "brand_name": "Servowarm", "model_name": "Elite 21 Condensing Combination", "model_qualifier": "", "winter_efficiency_pct": 85.6, "summer_efficiency_pct": 77.0, "comparative_hot_water_efficiency_pct": 54.2, "output_kw_max": 23.5, "final_year_of_manufacture": null, "raw": ["009860", "000091", "0", "2006/Jan/17 12:31", "Malvern Boilers", "Servowarm", "Elite 21 Condensing Combination", "", "", "2003", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "23.5", "23.5", "", "", "85.6", "77.0", "", "54.2", "", "2", "", "", "104", "1", "2", "120", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.2", "91.1", "", "", "", "", "90.4"]} -{"pcdb_id": 9861, "brand_name": "Warmworld", "model_name": "FFC Combi", "model_qualifier": "", "winter_efficiency_pct": 85.6, "summer_efficiency_pct": 77.0, "comparative_hot_water_efficiency_pct": 54.2, "output_kw_max": 23.5, "final_year_of_manufacture": null, "raw": ["009861", "000034", "0", "2006/Jan/31 12:06", "Warmworld", "Warmworld", "FFC Combi", "", "", "2003", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "23.5", "23.5", "", "", "85.6", "77.0", "", "54.2", "", "2", "", "", "104", "1", "2", "120", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.2", "91.1", "", "", "", "", "90.4"]} -{"pcdb_id": 9862, "brand_name": "Malvern", "model_name": "Dbi Combi", "model_qualifier": "", "winter_efficiency_pct": 86.6, "summer_efficiency_pct": 78.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 23.5, "final_year_of_manufacture": null, "raw": ["009862", "000023", "0", "2006/Jan/17 12:31", "Malvern Boilers", "Malvern", "Dbi Combi", "", "", "2003", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "23.5", "23.5", "", "", "86.6", "78.0", "", "54.8", "", "2", "1", "", "104", "1", "2", "120", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.2", "93.1", "", "", "", "", "92.4"]} -{"pcdb_id": 9863, "brand_name": "Servowarm", "model_name": "Elite 21 Condensing Combination", "model_qualifier": "", "winter_efficiency_pct": 86.6, "summer_efficiency_pct": 78.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 23.5, "final_year_of_manufacture": null, "raw": ["009863", "000091", "0", "2006/Jan/17 12:31", "Malvern Boilers", "Servowarm", "Elite 21 Condensing Combination", "", "", "2003", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "23.5", "23.5", "", "", "86.6", "78.0", "", "54.8", "", "2", "1", "", "104", "1", "2", "120", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.2", "93.1", "", "", "", "", "92.4"]} -{"pcdb_id": 9864, "brand_name": "Warmworld", "model_name": "FFC Combi", "model_qualifier": "", "winter_efficiency_pct": 86.6, "summer_efficiency_pct": 78.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 23.5, "final_year_of_manufacture": null, "raw": ["009864", "000034", "0", "2006/Jan/31 12:05", "Warmworld", "Warmworld", "FFC Combi", "", "", "2003", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "23.5", "23.5", "", "", "86.6", "78.0", "", "54.8", "", "2", "1", "", "104", "1", "2", "120", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.2", "93.1", "", "", "", "", "92.4"]} -{"pcdb_id": 9866, "brand_name": "ICI Caldaie", "model_name": "Solar", "model_qualifier": "System 28F", "winter_efficiency_pct": 81.2, "summer_efficiency_pct": 70.5, "comparative_hot_water_efficiency_pct": 51.5, "output_kw_max": 29.3, "final_year_of_manufacture": null, "raw": ["009866", "000077", "0", "2012/Mar/27 10:12", "ICI Caldaie", "ICI Caldaie", "Solar", "System 28F", "", "2003", "current", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "29.3", "29.3", "", "", "81.2", "70.5", "", "51.5", "", "2", "", "", "102", "1", "2", "10", "120", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "83.8", "81.5", "", "", "", "", "82.0"]} -{"pcdb_id": 9868, "brand_name": "ICI Caldaie", "model_name": "Solar", "model_qualifier": "Micro 28F", "winter_efficiency_pct": 81.0, "summer_efficiency_pct": 70.9, "comparative_hot_water_efficiency_pct": 49.9, "output_kw_max": 29.3, "final_year_of_manufacture": null, "raw": ["009868", "000077", "0", "2003/Oct/30 16:45", "ICI Caldaie", "ICI Caldaie", "Solar", "Micro 28F", "", "2003", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "29.3", "29.3", "", "", "81.0", "70.9", "", "49.9", "", "2", "", "", "104", "1", "2", "10", "120", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "83.8", "81.5", "", "", "", "", "82.0"]} -{"pcdb_id": 9869, "brand_name": "ICI Caldaie", "model_name": "Solar", "model_qualifier": "System 24F", "winter_efficiency_pct": 81.4, "summer_efficiency_pct": 70.7, "comparative_hot_water_efficiency_pct": 51.6, "output_kw_max": 25.3, "final_year_of_manufacture": null, "raw": ["009869", "000077", "0", "2012/Mar/27 10:12", "ICI Caldaie", "ICI Caldaie", "Solar", "System 24F", "", "2003", "current", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "25.3", "25.3", "", "", "81.4", "70.7", "", "51.6", "", "2", "", "", "102", "1", "2", "10", "120", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "84.3", "81.8", "", "", "", "", "82.3"]} -{"pcdb_id": 9870, "brand_name": "ICI Caldaie", "model_name": "Solar", "model_qualifier": "Micro 24F", "winter_efficiency_pct": 81.2, "summer_efficiency_pct": 71.1, "comparative_hot_water_efficiency_pct": 50.0, "output_kw_max": 25.3, "final_year_of_manufacture": null, "raw": ["009870", "000077", "0", "2003/Oct/30 16:46", "ICI Caldaie", "ICI Caldaie", "Solar", "Micro 24F", "", "2003", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "25.3", "25.3", "", "", "81.2", "71.1", "", "50.0", "", "2", "", "", "104", "1", "2", "10", "120", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "", "", "0004", "", "", "", "", "", "", "", "", "84.3", "81.8", "", "", "", "", "82.3"]} -{"pcdb_id": 9871, "brand_name": "Warmflow", "model_name": "Wall Mounted", "model_qualifier": "50/70 External", "winter_efficiency_pct": 85.9, "summer_efficiency_pct": 74.2, "comparative_hot_water_efficiency_pct": 54.2, "output_kw_max": 20.52, "final_year_of_manufacture": null, "raw": ["009871", "000063", "0", "2012/Mar/27 10:12", "Warmflow Engineering", "Warmflow", "Wall Mounted", "50/70 External", "", "2003", "current", "4", "2", "2", "1", "0", "", "", "1", "1", "2", "14.65", "20.52", "", "", "85.9", "74.2", "", "54.2", "", "2", "", "", "201", "1", "1", "115", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "84.8", "87.0", "", "", "", "", "86.6"]} -{"pcdb_id": 9872, "brand_name": "Warmflow", "model_name": "Wall Mounted", "model_qualifier": "50/70 Internal", "winter_efficiency_pct": 85.9, "summer_efficiency_pct": 74.2, "comparative_hot_water_efficiency_pct": 54.2, "output_kw_max": 20.52, "final_year_of_manufacture": null, "raw": ["009872", "000063", "0", "2012/Mar/27 10:12", "Warmflow Engineering", "Warmflow", "Wall Mounted", "50/70 Internal", "", "2003", "current", "4", "2", "1", "1", "0", "", "", "1", "3", "2", "14.65", "20.52", "", "", "85.9", "74.2", "", "54.2", "", "2", "", "", "201", "1", "1", "115", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "84.8", "87.0", "", "", "", "", "86.6"]} -{"pcdb_id": 9873, "brand_name": "Warmflow", "model_name": "Combi", "model_qualifier": "70/90 Kabin Pak", "winter_efficiency_pct": 83.9, "summer_efficiency_pct": 75.8, "comparative_hot_water_efficiency_pct": 38.3, "output_kw_max": 26.38, "final_year_of_manufacture": 2007, "raw": ["009873", "000063", "0", "2024/Jan/31 10:17", "Warmflow Engineering", "Warmflow", "Combi", "70/90 Kabin Pak", "", "2002", "2007", "4", "1", "2", "2", "0", "", "", "1", "1", "2", "20.52", "26.38", "", "", "83.9", "75.8", "", "38.3", "", "2", "", "", "203", "1", "1", "115", "0", "1", "1", "0", "70", "0", "25", "6", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "84.8", "86.8", "", "", "", "", "86.4"]} -{"pcdb_id": 9875, "brand_name": "Trianco", "model_name": "Tristar Optima", "model_qualifier": "Combi 28 CB", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 61.9, "output_kw_max": 28.0, "final_year_of_manufacture": 2007, "raw": ["009875", "000062", "0", "2009/Mar/24 12:11", "Trianco Redfyre", "Trianco", "Tristar Optima", "Combi 28 CB", "", "2003", "2007", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28", "28", "", "", "87.9", "79.3", "", "61.9", "", "2", "", "", "104", "1", "2", "110", "12.4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "", "0005", "", "", "", "", "", "", "", "", "87.9", "96.5", "", "", "", "", "94.9"]} -{"pcdb_id": 9877, "brand_name": "Trianco", "model_name": "Tristar Optima", "model_qualifier": "Combi 28CB LPG", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 62.7, "output_kw_max": 28.0, "final_year_of_manufacture": 2007, "raw": ["009877", "000062", "0", "2009/Mar/24 12:11", "Trianco Redfyre", "Trianco", "Tristar Optima", "Combi 28CB LPG", "", "2003", "2007", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "28", "28", "", "", "88.9", "80.3", "", "62.7", "", "2", "1", "", "104", "1", "2", "110", "12.4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "", "0005", "", "", "", "", "", "", "", "", "89.9", "98.6", "", "", "", "", "97.0"]} -{"pcdb_id": 9878, "brand_name": "Trianco", "model_name": "Tristar Optima", "model_qualifier": "System 28 SB", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 78.9, "comparative_hot_water_efficiency_pct": 57.6, "output_kw_max": 28.0, "final_year_of_manufacture": 2007, "raw": ["009878", "000062", "0", "2012/Mar/27 10:12", "Trianco Redfyre", "Trianco", "Tristar Optima", "System 28 SB", "", "2003", "2007", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "28", "28", "", "", "87.9", "78.9", "", "57.6", "", "2", "", "", "102", "1", "2", "110", "12.4", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "96.5", "", "", "", "", "94.9"]} -{"pcdb_id": 9879, "brand_name": "Trianco", "model_name": "Tristar Optima", "model_qualifier": "System 28 SB LPG", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 28.0, "final_year_of_manufacture": 2007, "raw": ["009879", "000062", "0", "2012/Mar/27 10:12", "Trianco Redfyre", "Trianco", "Tristar Optima", "System 28 SB LPG", "", "2003", "2007", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "28", "28", "", "", "88.9", "79.9", "", "58.3", "", "2", "1", "", "102", "1", "2", "110", "12.4", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.9", "98.6", "", "", "", "", "97.0"]} -{"pcdb_id": 9880, "brand_name": "Chaffoteaux et Maury", "model_name": "MX2 24 FF", "model_qualifier": "Minima", "winter_efficiency_pct": 79.0, "summer_efficiency_pct": 68.9, "comparative_hot_water_efficiency_pct": 48.5, "output_kw_max": 24.0, "final_year_of_manufacture": 2007, "raw": ["009880", "000010", "0", "2008/Feb/04 08:38", "Chaffoteaux et Maury", "Chaffoteaux et Maury", "MX2 24 FF", "Minima", "GC No. 41-980-28", "2003", "2007", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "24.0", "24.0", "", "", "79.0", "68.9", "", "48.5", "", "2", "", "", "104", "1", "2", "150", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.1", "78.4", "", "", "", "", "79.1"]} -{"pcdb_id": 9881, "brand_name": "Chaffoteaux et Maury", "model_name": "MX2 24 FF LPG", "model_qualifier": "Minima", "winter_efficiency_pct": 80.8, "summer_efficiency_pct": 70.7, "comparative_hot_water_efficiency_pct": 49.7, "output_kw_max": 24.0, "final_year_of_manufacture": 2007, "raw": ["009881", "000010", "0", "2008/Feb/04 08:38", "Chaffoteaux et Maury", "Chaffoteaux et Maury", "MX2 24 FF LPG", "Minima", "", "2003", "2007", "2", "2", "1", "2", "0", "", "", "1", "2", "2", "24.0", "24.0", "", "", "80.8", "70.7", "", "49.7", "", "2", "1", "", "104", "1", "2", "150", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "83.9", "80.1", "", "", "", "", "80.8"]} -{"pcdb_id": 9882, "brand_name": "Chaffoteaux et Maury", "model_name": "MX2 30 FF", "model_qualifier": "Minima", "winter_efficiency_pct": 80.3, "summer_efficiency_pct": 70.2, "comparative_hot_water_efficiency_pct": 49.4, "output_kw_max": 30.0, "final_year_of_manufacture": 2007, "raw": ["009882", "000010", "0", "2008/Feb/04 08:38", "Chaffoteaux et Maury", "Chaffoteaux et Maury", "MX2 30 FF", "Minima", "GC No. 41-980-29", "2003", "2007", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "30.0", "30.0", "", "", "80.3", "70.2", "", "49.4", "", "2", "", "", "104", "1", "2", "150", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "83.6", "80.1", "", "", "", "", "80.8"]} -{"pcdb_id": 9883, "brand_name": "Chaffoteaux et Maury", "model_name": "MX2 30 FF LPG", "model_qualifier": "Minima", "winter_efficiency_pct": 82.1, "summer_efficiency_pct": 72.0, "comparative_hot_water_efficiency_pct": 50.6, "output_kw_max": 30.0, "final_year_of_manufacture": 2007, "raw": ["009883", "000010", "0", "2008/Feb/04 08:38", "Chaffoteaux et Maury", "Chaffoteaux et Maury", "MX2 30 FF LPG", "Minima", "", "2003", "2007", "2", "2", "1", "2", "0", "", "", "1", "2", "2", "30.0", "30.0", "", "", "82.1", "72.0", "", "50.6", "", "2", "1", "", "104", "1", "2", "150", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "85.5", "81.9", "", "", "", "", "82.6"]} -{"pcdb_id": 9886, "brand_name": "Econoflame", "model_name": "Econoflame R30/65", "model_qualifier": "", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 65.0, "final_year_of_manufacture": null, "raw": ["009886", "000236", "0", "2012/Mar/27 10:12", "Stokvis Energy Systems", "Econoflame", "Econoflame R30/65", "", "", "2003", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "65", "65", "", "", "88.2", "79.2", "", "57.8", "", "2", "", "", "102", "1", "2", "98", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "97.3", "", "", "", "", "95.5"]} -{"pcdb_id": 9887, "brand_name": "Econoflame", "model_name": "Econoflame R30/45", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 43.0, "final_year_of_manufacture": null, "raw": ["009887", "000236", "0", "2012/Mar/27 10:12", "Stokvis Energy Systems", "Econoflame", "Econoflame R30/45", "", "", "2003", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "43.0", "43.0", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "97", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.2", "97.8", "", "", "", "", "95.9"]} -{"pcdb_id": 9889, "brand_name": "Econoflame", "model_name": "Econoflame R30/65", "model_qualifier": "LPG", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 65.0, "final_year_of_manufacture": null, "raw": ["009889", "000236", "0", "2012/Mar/27 10:12", "Stokvis Energy Systems", "Econoflame", "Econoflame R30/65", "LPG", "", "2003", "current", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "65", "65", "", "", "89.2", "80.2", "", "58.6", "", "2", "1", "", "102", "1", "2", "98", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.8", "99.5", "", "", "", "", "97.6"]} -{"pcdb_id": 9890, "brand_name": "Econoflame", "model_name": "Econoflame R30/45", "model_qualifier": "LPG", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 80.4, "comparative_hot_water_efficiency_pct": 58.7, "output_kw_max": 43.0, "final_year_of_manufacture": null, "raw": ["009890", "000236", "0", "2012/Mar/27 10:12", "Stokvis Energy Systems", "Econoflame", "Econoflame R30/45", "LPG", "", "2003", "current", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "43", "43", "", "", "89.4", "80.4", "", "58.7", "", "2", "1", "", "102", "1", "2", "97", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.2", "99.9", "", "", "", "", "98.1"]} -{"pcdb_id": 9891, "brand_name": "ELCO Klockner Heiztechnik", "model_name": "Ultron 22", "model_qualifier": "", "winter_efficiency_pct": 85.2, "summer_efficiency_pct": 77.6, "comparative_hot_water_efficiency_pct": 56.7, "output_kw_max": 21.0, "final_year_of_manufacture": null, "raw": ["009891", "000237", "0", "2012/Mar/27 10:12", "ELCO Klöckner Heiztechnik", "ELCO Klockner Heiztechnik", "Ultron 22", "", "", "1994", "current", "1", "1", "1", "1", "0", "", "", "2", "3", "2", "4", "21", "", "", "85.2", "77.6", "", "56.7", "", "2", "", "", "101", "1", "1", "45", "56", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "89.2", "92.8", "", "", "", "", "92.1"]} -{"pcdb_id": 9892, "brand_name": "Radiant", "model_name": "RBA CS 30/100", "model_qualifier": "", "winter_efficiency_pct": 81.9, "summer_efficiency_pct": 72.8, "comparative_hot_water_efficiency_pct": 32.9, "output_kw_max": 31.9, "final_year_of_manufacture": null, "raw": ["009892", "000088", "0", "2024/Jan/31 10:17", "Radiant Bruciatori SpA", "Radiant", "RBA CS 30/100", "", "", "2003", "current", "1", "1", "1", "2", "0", "", "", "1", "2", "2", "31.90", "31.90", "", "", "81.9", "72.8", "", "32.9", "", "2", "", "", "106", "1", "2", "170", "", "2", "2", "0", "104", "0", "15", "2", "60", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "83.3", "81.5", "", "", "", "", "81.9"]} -{"pcdb_id": 9893, "brand_name": "Radiant", "model_name": "RBA CS 30", "model_qualifier": "", "winter_efficiency_pct": 81.6, "summer_efficiency_pct": 72.5, "comparative_hot_water_efficiency_pct": 38.6, "output_kw_max": 31.9, "final_year_of_manufacture": null, "raw": ["009893", "000088", "0", "2024/Jan/31 10:17", "Radiant Bruciatori SpA", "Radiant", "RBA CS 30", "", "", "2003", "current", "1", "1", "1", "2", "0", "", "", "1", "2", "2", "31.90", "31.90", "", "", "81.6", "72.5", "", "38.6", "", "2", "", "", "106", "1", "2", "170", "", "2", "2", "0", "48.6", "0", "15", "2", "60", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "83.3", "81.5", "", "", "", "", "81.9"]} -{"pcdb_id": 9894, "brand_name": "Radiant", "model_name": "RMAS 20", "model_qualifier": "", "winter_efficiency_pct": 80.0, "summer_efficiency_pct": 69.9, "comparative_hot_water_efficiency_pct": 49.2, "output_kw_max": 23.76, "final_year_of_manufacture": null, "raw": ["009894", "000088", "0", "2006/Jan/17 12:31", "Radiant Bruciatori SpA", "Radiant", "RMAS 20", "", "", "2003", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "23.76", "23.76", "", "", "80.0", "69.9", "", "49.2", "", "2", "", "", "104", "1", "2", "170", "", "0", "", "", "8.8", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "83.4", "79.6", "", "", "", "", "80.3"]} -{"pcdb_id": 9895, "brand_name": "Ideal", "model_name": "icos", "model_qualifier": "HE15", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 14.6, "final_year_of_manufacture": 2011, "raw": ["009895", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "icos", "HE15", "47-397-83", "2003", "2011", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "14.6", "14.6", "", "", "89.0", "80.0", "", "58.4", "", "2", "", "", "102", "1", "2", "38", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.5", "99.0", "", "", "", "", "97.0"]} -{"pcdb_id": 9896, "brand_name": "Ideal", "model_name": "icos", "model_qualifier": "HE18", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 18.2, "final_year_of_manufacture": 2011, "raw": ["009896", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "icos", "HE18", "47-397-84", "2003", "2011", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18.2", "18.2", "", "", "88.7", "79.7", "", "58.2", "", "2", "", "", "102", "1", "2", "38", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.2", "98.5", "", "", "", "", "96.5"]} -{"pcdb_id": 9897, "brand_name": "Ideal", "model_name": "icos", "model_qualifier": "HE24", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 23.4, "final_year_of_manufacture": 2011, "raw": ["009897", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "icos", "HE24", "47-397-85", "2003", "2011", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "23.4", "23.4", "", "", "88.1", "79.1", "", "57.8", "", "2", "", "", "102", "1", "2", "38", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "97.1", "", "", "", "", "95.4"]} -{"pcdb_id": 9898, "brand_name": "Ideal", "model_name": "icos System", "model_qualifier": "HE 24", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 23.4, "final_year_of_manufacture": 2011, "raw": ["009898", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "icos System", "HE 24", "41-397-82", "2003", "2011", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "23.4", "23.4", "", "", "88.1", "79.1", "", "57.8", "", "2", "", "", "102", "1", "2", "38", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "97.1", "", "", "", "", "95.4"]} -{"pcdb_id": 9899, "brand_name": "Ideal", "model_name": "isar", "model_qualifier": "HE24", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 55.9, "output_kw_max": 23.4, "final_year_of_manufacture": 2011, "raw": ["009899", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "isar", "HE24", "47-348-31", "2003", "2011", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "23.4", "23.4", "", "", "88.1", "79.5", "", "55.9", "", "2", "", "", "104", "1", "2", "148", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "97.1", "", "", "", "", "95.4"]} -{"pcdb_id": 9900, "brand_name": "Ideal", "model_name": "isar", "model_qualifier": "HE30", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 55.9, "output_kw_max": 23.4, "final_year_of_manufacture": 2011, "raw": ["009900", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "isar", "HE30", "41-348-30", "2003", "2011", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "23.4", "23.4", "", "", "88.1", "79.5", "", "55.9", "", "2", "", "", "104", "1", "2", "148", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "97.1", "", "", "", "", "95.4"]} -{"pcdb_id": 9901, "brand_name": "Ideal", "model_name": "isar", "model_qualifier": "HE35", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 55.9, "output_kw_max": 23.4, "final_year_of_manufacture": 2011, "raw": ["009901", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "isar", "HE35", "47-348-29", "2003", "2011", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "23.4", "23.4", "", "", "88.1", "79.5", "", "55.9", "", "2", "", "", "104", "1", "2", "148", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "97.1", "", "", "", "", "95.4"]} -{"pcdb_id": 9902, "brand_name": "Ideal", "model_name": "istor", "model_qualifier": "HE260", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 81.1, "comparative_hot_water_efficiency_pct": 46.0, "output_kw_max": 23.4, "final_year_of_manufacture": 2011, "raw": ["009902", "000008", "0", "2024/Jan/31 10:17", "Ideal Boilers", "Ideal", "istor", "HE260", "41-394-13", "2003", "2011", "1", "1", "1", "2", "0", "", "", "2", "2", "2", "23.4", "23.4", "", "", "88.1", "81.1", "", "46.0", "", "2", "", "", "106", "1", "2", "148", "7", "2", "2", "0", "80", "0", "25", "2", "70", "1880", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "97.1", "", "", "", "", "95.4"]} -{"pcdb_id": 9903, "brand_name": "Ideal", "model_name": "istor", "model_qualifier": "HE325", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 81.2, "comparative_hot_water_efficiency_pct": 42.4, "output_kw_max": 23.4, "final_year_of_manufacture": 2011, "raw": ["009903", "000008", "0", "2024/Jan/31 10:17", "Ideal Boilers", "Ideal", "istor", "HE325", "41-394-14", "2003", "2011", "1", "1", "1", "2", "0", "", "", "2", "2", "2", "23.4", "23.4", "", "", "88.1", "81.2", "", "42.4", "", "2", "", "", "106", "1", "2", "148", "7", "2", "2", "0", "120", "0", "25", "2", "70", "2520", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "97.1", "", "", "", "", "95.4"]} -{"pcdb_id": 9904, "brand_name": "Ideal", "model_name": "Classic", "model_qualifier": "SE9 FF", "winter_efficiency_pct": 80.4, "summer_efficiency_pct": 70.3, "comparative_hot_water_efficiency_pct": 51.4, "output_kw_max": 8.8, "final_year_of_manufacture": 2011, "raw": ["009904", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "Classic", "SE9 FF", "GC No. 41 395 30", "2003", "2011", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "8.8", "8.8", "", "", "80.4", "70.3", "", "51.4", "", "2", "", "", "101", "1", "1", "100", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.9", "82.2", "", "", "", "", "82.1"]} -{"pcdb_id": 9905, "brand_name": "Ideal", "model_name": "Classic", "model_qualifier": "SE12 FF", "winter_efficiency_pct": 79.5, "summer_efficiency_pct": 69.4, "comparative_hot_water_efficiency_pct": 50.7, "output_kw_max": 11.7, "final_year_of_manufacture": 2011, "raw": ["009905", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "Classic", "SE12 FF", "GC No. 41 395 31", "2003", "2011", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "11.7", "11.7", "", "", "79.5", "69.4", "", "50.7", "", "2", "", "", "101", "1", "1", "100", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.0", "81.3", "", "", "", "", "81.2"]} -{"pcdb_id": 9906, "brand_name": "Ideal", "model_name": "Classic", "model_qualifier": "SE15 FF", "winter_efficiency_pct": 80.7, "summer_efficiency_pct": 70.6, "comparative_hot_water_efficiency_pct": 51.5, "output_kw_max": 14.7, "final_year_of_manufacture": 2011, "raw": ["009906", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "Classic", "SE15 FF", "GC No. 41 395 32", "2003", "2011", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "14.7", "14.7", "", "", "80.7", "70.6", "", "51.5", "", "2", "", "", "101", "1", "1", "100", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.3", "82.3", "", "", "", "", "82.3"]} -{"pcdb_id": 9907, "brand_name": "Ideal", "model_name": "Classic", "model_qualifier": "SE18 FF", "winter_efficiency_pct": 79.2, "summer_efficiency_pct": 69.1, "comparative_hot_water_efficiency_pct": 50.5, "output_kw_max": 17.6, "final_year_of_manufacture": 2011, "raw": ["009907", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "Classic", "SE18 FF", "GC No. 41 395 33", "2003", "2011", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "17.6", "17.6", "", "", "79.2", "69.1", "", "50.5", "", "2", "", "", "101", "1", "1", "100", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "80.8", "80.7", "", "", "", "", "80.7"]} -{"pcdb_id": 9908, "brand_name": "Ideal", "model_name": "Classic", "model_qualifier": "SE21 FF", "winter_efficiency_pct": 79.4, "summer_efficiency_pct": 69.3, "comparative_hot_water_efficiency_pct": 50.6, "output_kw_max": 20.5, "final_year_of_manufacture": 2011, "raw": ["009908", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "Classic", "SE21 FF", "GC No. 41 395 34", "2003", "2011", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "20.5", "20.5", "", "", "79.4", "69.3", "", "50.6", "", "2", "", "", "101", "1", "1", "100", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.2", "80.8", "", "", "", "", "80.9"]} -{"pcdb_id": 9909, "brand_name": "Ideal", "model_name": "Classic", "model_qualifier": "SE24 FF", "winter_efficiency_pct": 79.0, "summer_efficiency_pct": 68.9, "comparative_hot_water_efficiency_pct": 50.3, "output_kw_max": 23.4, "final_year_of_manufacture": 2011, "raw": ["009909", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "Classic", "SE24 FF", "GC No. 41 395 35", "2003", "2011", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "23.4", "23.4", "", "", "79.0", "68.9", "", "50.3", "", "2", "", "", "101", "1", "1", "100", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "80.6", "80.5", "", "", "", "", "80.6"]} -{"pcdb_id": 9910, "brand_name": "Ideal", "model_name": "Classic", "model_qualifier": "SE30 FF", "winter_efficiency_pct": 78.9, "summer_efficiency_pct": 68.8, "comparative_hot_water_efficiency_pct": 50.3, "output_kw_max": 29.3, "final_year_of_manufacture": 2011, "raw": ["009910", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "Classic", "SE30 FF", "GC No. 41 395 36", "2003", "2011", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "29.3", "29.3", "", "", "78.9", "68.8", "", "50.3", "", "2", "", "", "101", "1", "1", "100", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "80.5", "80.5", "", "", "", "", "80.5"]} -{"pcdb_id": 9914, "brand_name": "Ideal", "model_name": "Classic Slimline", "model_qualifier": "SE9 FF", "winter_efficiency_pct": 81.6, "summer_efficiency_pct": 71.5, "comparative_hot_water_efficiency_pct": 52.2, "output_kw_max": 8.8, "final_year_of_manufacture": 2011, "raw": ["009914", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "Classic Slimline", "SE9 FF", "GC No. 41 395 40", "2003", "2011", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "8.8", "8.8", "", "", "81.6", "71.5", "", "52.2", "", "2", "", "", "101", "1", "1", "100", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "83.1", "83.4", "", "", "", "", "83.4"]} -{"pcdb_id": 9915, "brand_name": "Ideal", "model_name": "Classic Slimline", "model_qualifier": "SE12 FF", "winter_efficiency_pct": 80.1, "summer_efficiency_pct": 70.0, "comparative_hot_water_efficiency_pct": 51.1, "output_kw_max": 11.7, "final_year_of_manufacture": 2011, "raw": ["009915", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "Classic Slimline", "SE12 FF", "GC No. 41 395 41", "2003", "2011", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "11.7", "11.7", "", "", "80.1", "70.0", "", "51.1", "", "2", "", "", "101", "1", "1", "100", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.8", "81.5", "", "", "", "", "81.6"]} -{"pcdb_id": 9916, "brand_name": "Ideal", "model_name": "Classic Slimline", "model_qualifier": "SE15 FF", "winter_efficiency_pct": 81.4, "summer_efficiency_pct": 71.3, "comparative_hot_water_efficiency_pct": 52.1, "output_kw_max": 14.7, "final_year_of_manufacture": 2011, "raw": ["009916", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "Classic Slimline", "SE15 FF", "GC No. 41 395 42", "2003", "2011", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "14.7", "14.7", "", "", "81.4", "71.3", "", "52.1", "", "2", "", "", "101", "1", "1", "100", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "83.0", "83.1", "", "", "", "", "83.1"]} -{"pcdb_id": 9917, "brand_name": "Ideal", "model_name": "Classic Slimline", "model_qualifier": "SE18 FF", "winter_efficiency_pct": 80.8, "summer_efficiency_pct": 70.7, "comparative_hot_water_efficiency_pct": 51.6, "output_kw_max": 17.6, "final_year_of_manufacture": 2011, "raw": ["009917", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "Classic Slimline", "SE18 FF", "GC No. 41 395 43", "2003", "2011", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "17.6", "17.6", "", "", "80.8", "70.7", "", "51.6", "", "2", "", "", "101", "1", "1", "100", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.4", "82.4", "", "", "", "", "82.4"]} -{"pcdb_id": 9918, "brand_name": "Ideal", "model_name": "Classic", "model_qualifier": "SE9 RS", "winter_efficiency_pct": 79.2, "summer_efficiency_pct": 69.1, "comparative_hot_water_efficiency_pct": 50.5, "output_kw_max": 8.8, "final_year_of_manufacture": 2005, "raw": ["009918", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "Classic", "SE9 RS", "GC No. 41 395 44", "2003", "2005", "1", "2", "1", "1", "0", "", "", "1", "2", "1", "8.8", "8.8", "", "", "79.2", "69.1", "", "50.5", "", "2", "", "", "101", "1", "1", "10", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.2", "80.5", "", "", "", "", "80.6"]} -{"pcdb_id": 9919, "brand_name": "Ideal", "model_name": "Classic", "model_qualifier": "SE12 RS", "winter_efficiency_pct": 79.8, "summer_efficiency_pct": 69.7, "comparative_hot_water_efficiency_pct": 50.9, "output_kw_max": 11.7, "final_year_of_manufacture": 2005, "raw": ["009919", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "Classic", "SE12 RS", "GC No. 41 395 45", "2003", "2005", "1", "2", "1", "1", "0", "", "", "1", "2", "1", "11.7", "11.7", "", "", "79.8", "69.7", "", "50.9", "", "2", "", "", "101", "1", "1", "10", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.2", "81.5", "", "", "", "", "81.5"]} -{"pcdb_id": 9920, "brand_name": "Ideal", "model_name": "Classic", "model_qualifier": "SE15 RS", "winter_efficiency_pct": 81.2, "summer_efficiency_pct": 71.1, "comparative_hot_water_efficiency_pct": 51.9, "output_kw_max": 14.7, "final_year_of_manufacture": 2005, "raw": ["009920", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "Classic", "SE15 RS", "GC No. 41 395 46", "2003", "2005", "1", "2", "1", "1", "0", "", "", "1", "2", "1", "14.7", "14.7", "", "", "81.2", "71.1", "", "51.9", "", "2", "", "", "101", "1", "1", "10", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.9", "82.6", "", "", "", "", "82.7"]} -{"pcdb_id": 9921, "brand_name": "Ideal", "model_name": "Classic", "model_qualifier": "SE18 RS", "winter_efficiency_pct": 79.9, "summer_efficiency_pct": 69.8, "comparative_hot_water_efficiency_pct": 51.0, "output_kw_max": 17.6, "final_year_of_manufacture": 2005, "raw": ["009921", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "Classic", "SE18 RS", "GC No. 41 395 99", "2003", "2005", "1", "2", "1", "1", "0", "", "", "1", "2", "1", "17.6", "17.6", "", "", "79.9", "69.8", "", "51.0", "", "2", "", "", "101", "1", "1", "10", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.9", "81.1", "", "", "", "", "81.2"]} -{"pcdb_id": 9922, "brand_name": "British / Scottish Gas", "model_name": "RD109", "model_qualifier": "", "winter_efficiency_pct": 80.4, "summer_efficiency_pct": 70.3, "comparative_hot_water_efficiency_pct": 51.4, "output_kw_max": 8.8, "final_year_of_manufacture": null, "raw": ["009922", "000008", "0", "2012/Mar/27 10:12", "Ideal Boilers", "British / Scottish Gas", "RD109", "", "GC No. 41 397 56", "2003", "current", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "8.8", "8.8", "", "", "80.4", "70.3", "", "51.4", "", "2", "", "", "101", "1", "1", "150", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.9", "82.2", "", "", "", "", "82.1"]} -{"pcdb_id": 9923, "brand_name": "British / Scottish Gas", "model_name": "RD112", "model_qualifier": "", "winter_efficiency_pct": 79.5, "summer_efficiency_pct": 69.4, "comparative_hot_water_efficiency_pct": 50.7, "output_kw_max": 11.7, "final_year_of_manufacture": null, "raw": ["009923", "000008", "0", "2012/Mar/27 10:12", "Ideal Boilers", "British / Scottish Gas", "RD112", "", "GC No. 41 397 57", "2003", "current", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "11.7", "11.7", "", "", "79.5", "69.4", "", "50.7", "", "2", "", "", "101", "1", "1", "150", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.0", "81.3", "", "", "", "", "81.2"]} -{"pcdb_id": 9924, "brand_name": "British / Scottish Gas", "model_name": "RD115", "model_qualifier": "", "winter_efficiency_pct": 80.7, "summer_efficiency_pct": 70.6, "comparative_hot_water_efficiency_pct": 51.5, "output_kw_max": 14.7, "final_year_of_manufacture": null, "raw": ["009924", "000008", "0", "2012/Mar/27 10:12", "Ideal Boilers", "British / Scottish Gas", "RD115", "", "GC No. 41 397 58", "2003", "current", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "14.7", "14.7", "", "", "80.7", "70.6", "", "51.5", "", "2", "", "", "101", "1", "1", "150", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.3", "82.3", "", "", "", "", "82.3"]} -{"pcdb_id": 9925, "brand_name": "British / Scottish Gas", "model_name": "RD118", "model_qualifier": "", "winter_efficiency_pct": 79.2, "summer_efficiency_pct": 69.1, "comparative_hot_water_efficiency_pct": 50.5, "output_kw_max": 17.6, "final_year_of_manufacture": null, "raw": ["009925", "000008", "0", "2012/Mar/27 10:12", "Ideal Boilers", "British / Scottish Gas", "RD118", "", "GC No. 41 397 59", "2003", "current", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "17.6", "17.6", "", "", "79.2", "69.1", "", "50.5", "", "2", "", "", "101", "1", "1", "150", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "80.8", "80.7", "", "", "", "", "80.7"]} -{"pcdb_id": 9926, "brand_name": "British / Scottish Gas", "model_name": "RD121", "model_qualifier": "", "winter_efficiency_pct": 79.4, "summer_efficiency_pct": 69.3, "comparative_hot_water_efficiency_pct": 50.6, "output_kw_max": 20.5, "final_year_of_manufacture": null, "raw": ["009926", "000008", "0", "2012/Mar/27 10:12", "Ideal Boilers", "British / Scottish Gas", "RD121", "", "GC No. 41 397 60", "2003", "current", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "20.5", "20.5", "", "", "79.4", "69.3", "", "50.6", "", "2", "", "", "101", "1", "1", "150", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.2", "80.8", "", "", "", "", "80.9"]} -{"pcdb_id": 9927, "brand_name": "British / Scottish Gas", "model_name": "RD124", "model_qualifier": "", "winter_efficiency_pct": 79.0, "summer_efficiency_pct": 68.9, "comparative_hot_water_efficiency_pct": 50.3, "output_kw_max": 23.4, "final_year_of_manufacture": null, "raw": ["009927", "000008", "0", "2012/Mar/27 10:12", "Ideal Boilers", "British / Scottish Gas", "RD124", "", "GC No. 41 397 61", "2003", "current", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "23.4", "23.4", "", "", "79.0", "68.9", "", "50.3", "", "2", "", "", "101", "1", "1", "150", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "80.6", "80.5", "", "", "", "", "80.6"]} -{"pcdb_id": 9928, "brand_name": "British / Scottish Gas", "model_name": "RD130", "model_qualifier": "", "winter_efficiency_pct": 78.9, "summer_efficiency_pct": 68.8, "comparative_hot_water_efficiency_pct": 50.3, "output_kw_max": 29.3, "final_year_of_manufacture": null, "raw": ["009928", "000008", "0", "2012/Mar/27 10:12", "Ideal Boilers", "British / Scottish Gas", "RD130", "", "GC No. 41 397 62", "2003", "current", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "29.3", "29.3", "", "", "78.9", "68.8", "", "50.3", "", "2", "", "", "101", "1", "1", "150", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "80.5", "80.5", "", "", "", "", "80.5"]} -{"pcdb_id": 9929, "brand_name": "Ideal", "model_name": "Classic", "model_qualifier": "SE9 FF Silver", "winter_efficiency_pct": 80.4, "summer_efficiency_pct": 70.3, "comparative_hot_water_efficiency_pct": 51.4, "output_kw_max": 8.8, "final_year_of_manufacture": 2005, "raw": ["009929", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "Classic", "SE9 FF Silver", "GC No. 41 397 63", "2003", "2005", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "8.8", "8.8", "", "", "80.4", "70.3", "", "51.4", "", "2", "", "", "101", "1", "1", "100", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.9", "82.2", "", "", "", "", "82.1"]} -{"pcdb_id": 9930, "brand_name": "Ideal", "model_name": "Classic", "model_qualifier": "SE12 FF Silver", "winter_efficiency_pct": 79.5, "summer_efficiency_pct": 69.4, "comparative_hot_water_efficiency_pct": 50.7, "output_kw_max": 11.7, "final_year_of_manufacture": 2005, "raw": ["009930", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "Classic", "SE12 FF Silver", "GC No. 41 397 64", "2003", "2005", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "11.7", "11.7", "", "", "79.5", "69.4", "", "50.7", "", "2", "", "", "101", "1", "1", "100", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.0", "81.3", "", "", "", "", "81.2"]} -{"pcdb_id": 9931, "brand_name": "Ideal", "model_name": "Classic", "model_qualifier": "SE15 FF Silver", "winter_efficiency_pct": 80.7, "summer_efficiency_pct": 70.6, "comparative_hot_water_efficiency_pct": 51.5, "output_kw_max": 14.7, "final_year_of_manufacture": 2005, "raw": ["009931", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "Classic", "SE15 FF Silver", "GC No. 41 397 65", "2003", "2005", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "14.7", "14.7", "", "", "80.7", "70.6", "", "51.5", "", "2", "", "", "101", "1", "1", "100", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.3", "82.3", "", "", "", "", "82.3"]} -{"pcdb_id": 9932, "brand_name": "Ideal", "model_name": "Classic", "model_qualifier": "SE18 FF Silver", "winter_efficiency_pct": 79.2, "summer_efficiency_pct": 69.1, "comparative_hot_water_efficiency_pct": 50.5, "output_kw_max": 17.6, "final_year_of_manufacture": 2005, "raw": ["009932", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "Classic", "SE18 FF Silver", "GC No. 41 397 68", "2003", "2005", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "17.6", "17.6", "", "", "79.2", "69.1", "", "50.5", "", "2", "", "", "101", "1", "1", "100", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "80.8", "80.7", "", "", "", "", "80.7"]} -{"pcdb_id": 9933, "brand_name": "Ideal", "model_name": "Classic", "model_qualifier": "SE21 FF Silver", "winter_efficiency_pct": 79.4, "summer_efficiency_pct": 69.3, "comparative_hot_water_efficiency_pct": 50.6, "output_kw_max": 20.5, "final_year_of_manufacture": 2005, "raw": ["009933", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "Classic", "SE21 FF Silver", "GC No. 41 397 69", "2003", "2005", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "20.5", "20.5", "", "", "79.4", "69.3", "", "50.6", "", "2", "", "", "101", "1", "1", "100", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.2", "80.8", "", "", "", "", "80.9"]} -{"pcdb_id": 9934, "brand_name": "Ideal", "model_name": "Classic", "model_qualifier": "SE24 FF Silver", "winter_efficiency_pct": 79.0, "summer_efficiency_pct": 68.9, "comparative_hot_water_efficiency_pct": 50.3, "output_kw_max": 23.4, "final_year_of_manufacture": 2005, "raw": ["009934", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "Classic", "SE24 FF Silver", "GC No. 41 397 70", "2003", "2005", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "23.4", "23.4", "", "", "79.0", "68.9", "", "50.3", "", "2", "", "", "101", "1", "1", "100", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "80.6", "80.5", "", "", "", "", "80.6"]} -{"pcdb_id": 9935, "brand_name": "Ideal", "model_name": "Classic", "model_qualifier": "SE30 FF Silver", "winter_efficiency_pct": 78.9, "summer_efficiency_pct": 68.8, "comparative_hot_water_efficiency_pct": 50.3, "output_kw_max": 29.3, "final_year_of_manufacture": 2005, "raw": ["009935", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "Classic", "SE30 FF Silver", "GC No. 41 397 71", "2003", "2005", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "29.3", "29.3", "", "", "78.9", "68.8", "", "50.3", "", "2", "", "", "101", "1", "1", "100", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "80.5", "80.5", "", "", "", "", "80.5"]} -{"pcdb_id": 9939, "brand_name": "British / Scottish Gas", "model_name": "RD109 Silver", "model_qualifier": "", "winter_efficiency_pct": 80.4, "summer_efficiency_pct": 70.3, "comparative_hot_water_efficiency_pct": 51.4, "output_kw_max": 8.8, "final_year_of_manufacture": null, "raw": ["009939", "000008", "0", "2012/Mar/27 10:12", "Ideal Boilers", "British / Scottish Gas", "RD109 Silver", "", "GC No. 41 397 75", "2003", "current", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "8.8", "8.8", "", "", "80.4", "70.3", "", "51.4", "", "2", "", "", "101", "1", "1", "150", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.9", "82.2", "", "", "", "", "82.1"]} -{"pcdb_id": 9940, "brand_name": "British / Scottish Gas", "model_name": "RD112 Silver", "model_qualifier": "", "winter_efficiency_pct": 79.5, "summer_efficiency_pct": 69.4, "comparative_hot_water_efficiency_pct": 50.7, "output_kw_max": 11.7, "final_year_of_manufacture": null, "raw": ["009940", "000008", "0", "2012/Mar/27 10:12", "Ideal Boilers", "British / Scottish Gas", "RD112 Silver", "", "GC No. 41 397 76", "2003", "current", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "11.7", "11.7", "", "", "79.5", "69.4", "", "50.7", "", "2", "", "", "101", "1", "1", "150", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.0", "81.3", "", "", "", "", "81.2"]} -{"pcdb_id": 9941, "brand_name": "British / Scottish Gas", "model_name": "RD115 Silver", "model_qualifier": "", "winter_efficiency_pct": 80.7, "summer_efficiency_pct": 70.6, "comparative_hot_water_efficiency_pct": 51.5, "output_kw_max": 14.7, "final_year_of_manufacture": null, "raw": ["009941", "000008", "0", "2012/Mar/27 10:12", "Ideal Boilers", "British / Scottish Gas", "RD115 Silver", "", "GC No. 41 397 77", "2003", "current", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "14.7", "14.7", "", "", "80.7", "70.6", "", "51.5", "", "2", "", "", "101", "1", "1", "150", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.3", "82.3", "", "", "", "", "82.3"]} -{"pcdb_id": 9942, "brand_name": "British / Scottish Gas", "model_name": "RD118 Silver", "model_qualifier": "", "winter_efficiency_pct": 79.2, "summer_efficiency_pct": 69.1, "comparative_hot_water_efficiency_pct": 50.5, "output_kw_max": 17.6, "final_year_of_manufacture": null, "raw": ["009942", "000008", "0", "2012/Mar/27 10:12", "Ideal Boilers", "British / Scottish Gas", "RD118 Silver", "", "GC No. 41 397 78", "2003", "current", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "17.6", "17.6", "", "", "79.2", "69.1", "", "50.5", "", "2", "", "", "101", "1", "1", "150", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "80.8", "80.7", "", "", "", "", "80.7"]} -{"pcdb_id": 9943, "brand_name": "British / Scottish Gas", "model_name": "RD121 Silver", "model_qualifier": "", "winter_efficiency_pct": 79.4, "summer_efficiency_pct": 69.3, "comparative_hot_water_efficiency_pct": 50.6, "output_kw_max": 20.5, "final_year_of_manufacture": null, "raw": ["009943", "000008", "0", "2012/Mar/27 10:12", "Ideal Boilers", "British / Scottish Gas", "RD121 Silver", "", "GC No. 41 397 79", "2003", "current", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "20.5", "20.5", "", "", "79.4", "69.3", "", "50.6", "", "2", "", "", "101", "1", "1", "150", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.2", "80.8", "", "", "", "", "80.9"]} -{"pcdb_id": 9944, "brand_name": "British / Scottish Gas", "model_name": "RD124 Silver", "model_qualifier": "", "winter_efficiency_pct": 79.0, "summer_efficiency_pct": 68.9, "comparative_hot_water_efficiency_pct": 50.3, "output_kw_max": 23.4, "final_year_of_manufacture": null, "raw": ["009944", "000008", "0", "2012/Mar/27 10:12", "Ideal Boilers", "British / Scottish Gas", "RD124 Silver", "", "GC No. 41 397 80", "2003", "current", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "23.4", "23.4", "", "", "79.0", "68.9", "", "50.3", "", "2", "", "", "101", "1", "1", "150", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "80.6", "80.5", "", "", "", "", "80.6"]} -{"pcdb_id": 9945, "brand_name": "British / Scottish Gas", "model_name": "RD130 Silver", "model_qualifier": "", "winter_efficiency_pct": 78.9, "summer_efficiency_pct": 68.8, "comparative_hot_water_efficiency_pct": 50.3, "output_kw_max": 29.3, "final_year_of_manufacture": null, "raw": ["009945", "000008", "0", "2012/Mar/27 10:12", "Ideal Boilers", "British / Scottish Gas", "RD130 Silver", "", "GC No. 41 397 81", "2003", "current", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "29.3", "29.3", "", "", "78.9", "68.8", "", "50.3", "", "2", "", "", "101", "1", "1", "150", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "80.5", "80.5", "", "", "", "", "80.5"]} -{"pcdb_id": 9946, "brand_name": "Optia", "model_name": "FF30", "model_qualifier": "", "winter_efficiency_pct": 80.4, "summer_efficiency_pct": 70.3, "comparative_hot_water_efficiency_pct": 51.4, "output_kw_max": 8.8, "final_year_of_manufacture": null, "raw": ["009946", "000008", "0", "2012/Mar/27 10:12", "Ideal Boilers", "Optia", "FF30", "", "GC No. 41 391 54", "2003", "current", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "8.8", "8.8", "", "", "80.4", "70.3", "", "51.4", "", "2", "", "", "101", "1", "1", "100", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.9", "82.2", "", "", "", "", "82.1"]} -{"pcdb_id": 9947, "brand_name": "Optia", "model_name": "FF40", "model_qualifier": "", "winter_efficiency_pct": 79.5, "summer_efficiency_pct": 69.4, "comparative_hot_water_efficiency_pct": 50.7, "output_kw_max": 11.7, "final_year_of_manufacture": null, "raw": ["009947", "000008", "0", "2012/Mar/27 10:12", "Ideal Boilers", "Optia", "FF40", "", "GC No. 41 391 95", "2003", "current", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "11.7", "11.7", "", "", "79.5", "69.4", "", "50.7", "", "2", "", "", "101", "1", "1", "100", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.0", "81.3", "", "", "", "", "81.2"]} -{"pcdb_id": 9948, "brand_name": "Optia", "model_name": "FF50", "model_qualifier": "", "winter_efficiency_pct": 80.7, "summer_efficiency_pct": 70.6, "comparative_hot_water_efficiency_pct": 51.5, "output_kw_max": 14.7, "final_year_of_manufacture": null, "raw": ["009948", "000008", "0", "2012/Mar/27 10:12", "Ideal Boilers", "Optia", "FF50", "", "GC No. 41 391 96", "2003", "current", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "14.7", "14.7", "", "", "80.7", "70.6", "", "51.5", "", "2", "", "", "101", "1", "1", "100", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.3", "82.3", "", "", "", "", "82.3"]} -{"pcdb_id": 9949, "brand_name": "Optia", "model_name": "FF60", "model_qualifier": "", "winter_efficiency_pct": 79.2, "summer_efficiency_pct": 69.1, "comparative_hot_water_efficiency_pct": 50.5, "output_kw_max": 17.6, "final_year_of_manufacture": null, "raw": ["009949", "000008", "0", "2012/Mar/27 10:12", "Ideal Boilers", "Optia", "FF60", "", "GC No. 41 391 97", "2003", "current", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "17.6", "17.6", "", "", "79.2", "69.1", "", "50.5", "", "2", "", "", "101", "1", "1", "100", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "80.8", "80.7", "", "", "", "", "80.7"]} -{"pcdb_id": 9950, "brand_name": "Optia", "model_name": "FF70", "model_qualifier": "", "winter_efficiency_pct": 79.4, "summer_efficiency_pct": 69.3, "comparative_hot_water_efficiency_pct": 50.6, "output_kw_max": 20.5, "final_year_of_manufacture": null, "raw": ["009950", "000008", "0", "2012/Mar/27 10:12", "Ideal Boilers", "Optia", "FF70", "", "GC No. 41 391 98", "2003", "current", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "20.5", "20.5", "", "", "79.4", "69.3", "", "50.6", "", "2", "", "", "101", "1", "1", "100", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.2", "80.8", "", "", "", "", "80.9"]} -{"pcdb_id": 9951, "brand_name": "Optia", "model_name": "FF80", "model_qualifier": "", "winter_efficiency_pct": 79.0, "summer_efficiency_pct": 68.9, "comparative_hot_water_efficiency_pct": 50.3, "output_kw_max": 23.4, "final_year_of_manufacture": null, "raw": ["009951", "000008", "0", "2012/Mar/27 10:12", "Ideal Boilers", "Optia", "FF80", "", "GC No. 41 391 99", "2003", "current", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "23.4", "23.4", "", "", "79.0", "68.9", "", "50.3", "", "2", "", "", "101", "1", "1", "100", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "80.6", "80.5", "", "", "", "", "80.6"]} -{"pcdb_id": 9952, "brand_name": "Optia", "model_name": "FF100", "model_qualifier": "", "winter_efficiency_pct": 78.9, "summer_efficiency_pct": 68.8, "comparative_hot_water_efficiency_pct": 50.3, "output_kw_max": 29.3, "final_year_of_manufacture": null, "raw": ["009952", "000008", "0", "2012/Mar/27 10:12", "Ideal Boilers", "Optia", "FF100", "", "GC No. 41 391 01", "2003", "current", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "29.3", "29.3", "", "", "78.9", "68.8", "", "50.3", "", "2", "", "", "101", "1", "1", "100", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "80.5", "80.5", "", "", "", "", "80.5"]} -{"pcdb_id": 9953, "brand_name": "Saunier Duval", "model_name": "EnviroPlus F28E", "model_qualifier": "", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 56.4, "output_kw_max": 29.0, "final_year_of_manufacture": null, "raw": ["009953", "000206", "0", "2009/Mar/31 14:32", "Hepworth Heating", "Saunier Duval", "EnviroPlus F28E", "", "GC 47-920-39", "2003", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "29.0", "29.0", "", "", "88.9", "80.3", "", "56.4", "", "2", "", "", "104", "1", "2", "180", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.4", "98.8", "", "", "", "", "96.9"]} -{"pcdb_id": 9954, "brand_name": "Saunier Duval", "model_name": "EnviroPlus F28E SB", "model_qualifier": "", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 29.0, "final_year_of_manufacture": null, "raw": ["009954", "000206", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Saunier Duval", "EnviroPlus F28E SB", "", "GC 41-920-37", "2003", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "29.0", "29.0", "", "", "88.9", "79.9", "", "58.3", "", "2", "", "", "102", "1", "2", "180", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.4", "98.8", "", "", "", "", "96.9"]} -{"pcdb_id": 9955, "brand_name": "Alpha", "model_name": "CD32C", "model_qualifier": "", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 56.0, "output_kw_max": 32.0, "final_year_of_manufacture": 2007, "raw": ["009955", "000001", "0", "2011/Sep/06 13:10", "Alpha Therm", "Alpha", "CD32C", "", "", "2003", "2007", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "32", "32", "", "", "88.2", "79.6", "", "56.0", "", "2", "", "", "104", "1", "2", "140", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.1", "96.8", "", "", "", "", "95.3"]} -{"pcdb_id": 9957, "brand_name": "MHS Boilers", "model_name": "Strata Streamline", "model_qualifier": "75", "winter_efficiency_pct": 87.7, "summer_efficiency_pct": 78.7, "comparative_hot_water_efficiency_pct": 57.5, "output_kw_max": 67.8, "final_year_of_manufacture": null, "raw": ["009957", "000024", "0", "2012/Mar/27 10:12", "MHS Boilers", "MHS Boilers", "Strata Streamline", "75", "", "2003", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "67.8", "67.8", "", "", "87.7", "78.7", "", "57.5", "", "2", "", "", "102", "1", "2", "60", "6", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.3", "96.2", "", "", "", "", "94.5"]} -{"pcdb_id": 9958, "brand_name": "MHS Boilers", "model_name": "Strata Streamline", "model_qualifier": "47", "winter_efficiency_pct": 87.6, "summer_efficiency_pct": 78.6, "comparative_hot_water_efficiency_pct": 57.4, "output_kw_max": 43.9, "final_year_of_manufacture": null, "raw": ["009958", "000024", "0", "2012/Mar/27 10:12", "MHS Boilers", "MHS Boilers", "Strata Streamline", "47", "", "2004", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "43.9", "43.9", "", "", "87.6", "78.6", "", "57.4", "", "2", "", "", "102", "1", "2", "60", "6", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.0", "96.2", "", "", "", "", "94.5"]} -{"pcdb_id": 9960, "brand_name": "Boulter", "model_name": "Camray 5", "model_qualifier": "U 40/65 S", "winter_efficiency_pct": 86.6, "summer_efficiency_pct": 74.9, "comparative_hot_water_efficiency_pct": 54.7, "output_kw_max": 19.0, "final_year_of_manufacture": null, "raw": ["009960", "000041", "0", "2012/Mar/27 10:12", "Boulter Buderus", "Boulter", "Camray 5", "U 40/65 S", "", "2003", "current", "4", "1", "1", "1", "0", "", "", "1", "3", "2", "11.7", "19", "", "", "86.6", "74.9", "", "54.7", "", "2", "", "", "201", "1", "1", "150", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.0", "87.0", "", "", "", "", "87.0"]} -{"pcdb_id": 9961, "brand_name": "Boulter", "model_name": "Camray 5", "model_qualifier": "U 65/90 SB", "winter_efficiency_pct": 85.3, "summer_efficiency_pct": 73.6, "comparative_hot_water_efficiency_pct": 53.7, "output_kw_max": 26.4, "final_year_of_manufacture": null, "raw": ["009961", "000041", "0", "2012/Mar/27 10:12", "Boulter Buderus", "Boulter", "Camray 5", "U 65/90 SB", "", "2003", "current", "4", "1", "1", "1", "0", "", "", "1", "3", "2", "19", "26.4", "", "", "85.3", "73.6", "", "53.7", "", "2", "", "", "201", "1", "1", "150", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "84.8", "85.7", "", "", "", "", "85.6"]} -{"pcdb_id": 9962, "brand_name": "Boulter", "model_name": "Camray 5", "model_qualifier": "U 95 / 130 SA", "winter_efficiency_pct": 86.4, "summer_efficiency_pct": 74.7, "comparative_hot_water_efficiency_pct": 54.6, "output_kw_max": 38.1, "final_year_of_manufacture": null, "raw": ["009962", "000041", "0", "2012/Mar/27 10:12", "Boulter Buderus", "Boulter", "Camray 5", "U 95 / 130 SA", "", "2003", "current", "4", "1", "1", "1", "0", "", "", "1", "3", "2", "27.8", "38.1", "", "", "86.4", "74.7", "", "54.6", "", "2", "", "", "201", "1", "1", "150", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.0", "86.8", "", "", "", "", "86.6"]} -{"pcdb_id": 9963, "brand_name": "Boulter", "model_name": "Camray 5", "model_qualifier": "40/65 EX", "winter_efficiency_pct": 86.6, "summer_efficiency_pct": 74.9, "comparative_hot_water_efficiency_pct": 54.7, "output_kw_max": 19.0, "final_year_of_manufacture": null, "raw": ["009963", "000041", "0", "2012/Mar/27 10:12", "Boulter Buderus", "Boulter", "Camray 5", "40/65 EX", "", "2003", "current", "4", "1", "2", "1", "0", "", "", "1", "1", "2", "11.7", "19", "", "", "86.6", "74.9", "", "54.7", "", "2", "", "", "201", "1", "1", "150", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.0", "87.0", "", "", "", "", "87.0"]} -{"pcdb_id": 9964, "brand_name": "Boulter", "model_name": "Camray 5", "model_qualifier": "Combi 90BE", "winter_efficiency_pct": 84.0, "summer_efficiency_pct": 74.5, "comparative_hot_water_efficiency_pct": 52.4, "output_kw_max": 26.4, "final_year_of_manufacture": null, "raw": ["009964", "000041", "0", "2004/Jan/28 10:27", "Boulter Buderus", "Boulter", "Camray 5", "Combi 90BE", "", "2003", "current", "4", "1", "2", "2", "0", "", "", "1", "1", "2", "26.4", "26.4", "", "", "84.0", "74.5", "", "52.4", "", "2", "", "", "202", "1", "1", "150", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.2", "86.4", "", "", "", "", "86.2"]} -{"pcdb_id": 9965, "brand_name": "Boulter", "model_name": "Camray 5", "model_qualifier": "65/90 EX", "winter_efficiency_pct": 85.8, "summer_efficiency_pct": 74.1, "comparative_hot_water_efficiency_pct": 54.1, "output_kw_max": 26.4, "final_year_of_manufacture": null, "raw": ["009965", "000041", "0", "2012/Mar/27 10:12", "Boulter Buderus", "Boulter", "Camray 5", "65/90 EX", "", "2003", "current", "4", "1", "2", "1", "0", "", "", "1", "1", "2", "19", "26.4", "", "", "85.8", "74.1", "", "54.1", "", "2", "", "", "201", "1", "1", "150", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.2", "86.4", "", "", "", "", "86.2"]} -{"pcdb_id": 9966, "brand_name": "Saunier Duval", "model_name": "Thema Classic F35E", "model_qualifier": "", "winter_efficiency_pct": 79.5, "summer_efficiency_pct": 69.4, "comparative_hot_water_efficiency_pct": 48.8, "output_kw_max": 34.8, "final_year_of_manufacture": null, "raw": ["009966", "000206", "0", "2006/Jan/17 12:31", "Hepworth Heating", "Saunier Duval", "Thema Classic F35E", "", "GC 47-920-40", "2003", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "34.8", "34.8", "", "", "79.5", "69.4", "", "48.8", "", "2", "", "", "104", "1", "2", "130", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.9", "79.5", "", "", "", "", "79.9"]} -{"pcdb_id": 9967, "brand_name": "Glow-worm", "model_name": "35ci", "model_qualifier": "", "winter_efficiency_pct": 79.5, "summer_efficiency_pct": 69.4, "comparative_hot_water_efficiency_pct": 48.8, "output_kw_max": 34.8, "final_year_of_manufacture": null, "raw": ["009967", "000207", "0", "2006/Jan/17 12:31", "Hepworth Heating", "Glow-worm", "35ci", "", "GC 47-047-20", "2003", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "34.8", "34.8", "", "", "79.5", "69.4", "", "48.8", "", "2", "", "", "104", "1", "2", "130", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.9", "79.5", "", "", "", "", "79.9"]} -{"pcdb_id": 9968, "brand_name": "Glow-worm", "model_name": "12hxi", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 12.0, "final_year_of_manufacture": null, "raw": ["009968", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "12hxi", "", "GC 41-047-73", "2004", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "12.0", "12.0", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "60", "15", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.7", "96.5", "", "", "", "", "95.0"]} -{"pcdb_id": 9969, "brand_name": "Glow-worm", "model_name": "15hxi", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 15.0, "final_year_of_manufacture": null, "raw": ["009969", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "15hxi", "", "GC 41-047-74", "2004", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "15.0", "15.0", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "60", "15", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0085", "", "", "", "", "", "", "", "", "88.6", "96.5", "", "", "", "", "95.0"]} -{"pcdb_id": 9970, "brand_name": "Glow-worm", "model_name": "18sxi", "model_qualifier": "", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 78.9, "comparative_hot_water_efficiency_pct": 57.6, "output_kw_max": 18.0, "final_year_of_manufacture": null, "raw": ["009970", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "18sxi", "", "GC 41-047-72", "2004", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18.0", "18.0", "", "", "87.9", "78.9", "", "57.6", "", "2", "", "", "102", "1", "2", "180", "15", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.6", "96.3", "", "", "", "", "94.8"]} -{"pcdb_id": 9971, "brand_name": "Glow-worm", "model_name": "24hxi", "model_qualifier": "", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 24.0, "final_year_of_manufacture": null, "raw": ["009971", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "24hxi", "", "GC 41-047-69", "2004", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24.0", "24.0", "", "", "88.2", "79.2", "", "57.9", "", "2", "", "", "102", "1", "2", "60", "15", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.7", "97.0", "", "", "", "", "95.4"]} -{"pcdb_id": 9973, "brand_name": "Fagor Electrodomesticos S.Coop", "model_name": "FE-24E Supercompact", "model_qualifier": "Fe-24EUK", "winter_efficiency_pct": 80.9, "summer_efficiency_pct": 70.8, "comparative_hot_water_efficiency_pct": 49.8, "output_kw_max": 23.7, "final_year_of_manufacture": null, "raw": ["009973", "000219", "0", "2013/Jun/25 14:29", "Fagor Electrodomesticos S.Coop", "Fagor Electrodomesticos S.Coop", "FE-24E Supercompact", "Fe-24EUK", "912111011", "2003", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "23.7", "23.7", "", "", "80.9", "70.8", "", "49.8", "", "2", "", "", "104", "1", "2", "30", "4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "0", "", "0004", "", "", "", "", "", "", "", "", "82.1", "82.2", "", "", "", "", "82.2"]} -{"pcdb_id": 9974, "brand_name": "Fagor Electrodomesticos S.Coop", "model_name": "FE-24E Supercompact", "model_qualifier": "FE-24EUK N", "winter_efficiency_pct": 80.9, "summer_efficiency_pct": 70.8, "comparative_hot_water_efficiency_pct": 49.8, "output_kw_max": 23.7, "final_year_of_manufacture": null, "raw": ["009974", "000219", "0", "2013/Jun/25 14:29", "Fagor Electrodomesticos S.Coop", "Fagor Electrodomesticos S.Coop", "FE-24E Supercompact", "FE-24EUK N", "912110879", "2003", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "23.7", "23.7", "", "", "80.9", "70.8", "", "49.8", "", "2", "", "", "104", "1", "2", "30", "4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "0", "", "0004", "", "", "", "", "", "", "", "", "82.1", "82.2", "", "", "", "", "82.2"]} -{"pcdb_id": 9976, "brand_name": "Fagor Electrodomesticos S.Coop", "model_name": "FE-24E Supercompact", "model_qualifier": "FE-24EUK", "winter_efficiency_pct": 83.0, "summer_efficiency_pct": 72.9, "comparative_hot_water_efficiency_pct": 51.3, "output_kw_max": 23.7, "final_year_of_manufacture": null, "raw": ["009976", "000219", "0", "2013/Jun/25 14:29", "Fagor Electrodomesticos S.Coop", "Fagor Electrodomesticos S.Coop", "FE-24E Supercompact", "FE-24EUK", "912111039", "2003", "current", "2", "2", "1", "2", "0", "", "", "1", "2", "2", "23.7", "23.7", "", "", "83.0", "72.9", "", "51.3", "", "2", "0", "", "104", "1", "2", "30", "4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "0", "", "0004", "", "", "", "", "", "", "", "", "84.6", "87.0", "", "", "", "", "86.6"]} -{"pcdb_id": 9977, "brand_name": "Fagor Electrodomesticos S.Coop", "model_name": "FEE-35MA Supercompact", "model_qualifier": "FEE-35MAUK N", "winter_efficiency_pct": 80.9, "summer_efficiency_pct": 70.8, "comparative_hot_water_efficiency_pct": 55.3, "output_kw_max": 34.5, "final_year_of_manufacture": null, "raw": ["009977", "000219", "0", "2013/Jun/25 14:30", "Fagor Electrodomesticos S.Coop", "Fagor Electrodomesticos S.Coop", "FEE-35MA Supercompact", "FEE-35MAUK N", "912110913", "2003", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "34.5", "34.5", "", "", "80.9", "70.8", "", "55.3", "", "2", "", "", "104", "1", "2", "65", "10", "0", "", "", "2.5", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "", "0004", "", "", "", "", "", "", "", "", "83.1", "81.4", "", "", "", "", "81.7"]} -{"pcdb_id": 9978, "brand_name": "Fagor Electrodomesticos S.Coop", "model_name": "FEE-35MA Supercompact", "model_qualifier": "FEE-35MAUK", "winter_efficiency_pct": 82.7, "summer_efficiency_pct": 72.6, "comparative_hot_water_efficiency_pct": 56.7, "output_kw_max": 34.5, "final_year_of_manufacture": null, "raw": ["009978", "000219", "0", "2013/Jun/25 14:30", "Fagor Electrodomesticos S.Coop", "Fagor Electrodomesticos S.Coop", "FEE-35MA Supercompact", "FEE-35MAUK", "912111057", "2003", "current", "2", "2", "1", "2", "0", "", "", "1", "2", "2", "34.5", "34.5", "", "", "82.7", "72.6", "", "56.7", "", "2", "0", "", "104", "1", "2", "65", "10", "0", "", "", "2.5", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "", "0004", "", "", "", "", "", "", "", "", "84.1", "86.4", "", "", "", "", "86.0"]} -{"pcdb_id": 9979, "brand_name": "Fagor Electrodomesticos S.Coop", "model_name": "FE-27E Supercompact", "model_qualifier": "FE-27EUK N", "winter_efficiency_pct": 79.3, "summer_efficiency_pct": 69.2, "comparative_hot_water_efficiency_pct": 48.7, "output_kw_max": 27.0, "final_year_of_manufacture": null, "raw": ["009979", "000219", "0", "2013/Jun/25 14:30", "Fagor Electrodomesticos S.Coop", "Fagor Electrodomesticos S.Coop", "FE-27E Supercompact", "FE-27EUK N", "912110897", "2003", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "27", "27", "", "", "79.3", "69.2", "", "48.7", "", "2", "", "", "104", "1", "2", "30", "4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "0", "", "0004", "", "", "", "", "", "", "", "", "81.5", "79.6", "", "", "", "", "79.9"]} -{"pcdb_id": 9980, "brand_name": "Fagor Electrodomesticos S.Coop", "model_name": "FE-27E Supercompact", "model_qualifier": "FE-27EUK", "winter_efficiency_pct": 80.7, "summer_efficiency_pct": 70.6, "comparative_hot_water_efficiency_pct": 49.6, "output_kw_max": 27.0, "final_year_of_manufacture": null, "raw": ["009980", "000219", "0", "2013/Jun/25 14:31", "Fagor Electrodomesticos S.Coop", "Fagor Electrodomesticos S.Coop", "FE-27E Supercompact", "FE-27EUK", "912111048", "2003", "current", "2", "2", "1", "2", "0", "", "", "1", "2", "2", "27", "27", "", "", "80.7", "70.6", "", "49.6", "", "2", "0", "", "104", "1", "2", "1", "30", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.9", "80.9", "", "", "", "", "81.2"]} -{"pcdb_id": 9981, "brand_name": "Ferroli", "model_name": "Maxima", "model_qualifier": "35S", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 34.6, "final_year_of_manufacture": 2008, "raw": ["009981", "000097", "0", "2012/Mar/27 10:12", "Ferroli SpA", "Ferroli", "Maxima", "35S", "", "2004", "2008", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "34.6", "34.6", "", "", "88.9", "79.9", "", "58.3", "", "2", "", "", "102", "1", "2", "150", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.6", "98.3", "", "", "", "", "96.7"]} -{"pcdb_id": 9983, "brand_name": "Potterton", "model_name": "Paramount 60", "model_qualifier": "Natural Gas", "winter_efficiency_pct": 87.8, "summer_efficiency_pct": 78.8, "comparative_hot_water_efficiency_pct": 57.5, "output_kw_max": 59.5, "final_year_of_manufacture": 2010, "raw": ["009983", "000238", "0", "2012/Mar/27 10:12", "August Brötje GmbH", "Potterton", "Paramount 60", "Natural Gas", "", "2002", "2010", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "59.5", "59.5", "", "", "87.8", "78.8", "", "57.5", "", "2", "", "", "102", "1", "2", "75", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.3", "96.5", "", "", "", "", "94.8"]} -{"pcdb_id": 9984, "brand_name": "Potterton", "model_name": "Paramount 40", "model_qualifier": "Natural Gas", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 78.9, "comparative_hot_water_efficiency_pct": 57.6, "output_kw_max": 39.0, "final_year_of_manufacture": 2010, "raw": ["009984", "000238", "0", "2012/Mar/27 10:12", "August Brötje GmbH", "Potterton", "Paramount 40", "Natural Gas", "", "2002", "2010", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "39", "39", "", "", "87.9", "78.9", "", "57.6", "", "2", "", "", "102", "1", "2", "60", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.2", "96.8", "", "", "", "", "95.0"]} -{"pcdb_id": 9985, "brand_name": "Sabre", "model_name": "28", "model_qualifier": "LPG", "winter_efficiency_pct": 82.7, "summer_efficiency_pct": 72.6, "comparative_hot_water_efficiency_pct": 51.1, "output_kw_max": 28.0, "final_year_of_manufacture": null, "raw": ["009985", "000011", "0", "2006/Jan/17 12:31", "Vokera", "Sabre", "28", "LPG", "829", "2004", "current", "2", "2", "1", "2", "0", "", "", "1", "2", "2", "28.0", "28.0", "", "", "82.7", "72.6", "", "51.1", "", "2", "0", "", "104", "1", "2", "125", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "84.5", "83.4", "", "", "", "", "83.6"]} -{"pcdb_id": 9986, "brand_name": "Sabre", "model_name": "24", "model_qualifier": "LPG", "winter_efficiency_pct": 83.1, "summer_efficiency_pct": 73.0, "comparative_hot_water_efficiency_pct": 51.3, "output_kw_max": 24.0, "final_year_of_manufacture": null, "raw": ["009986", "000011", "0", "2006/Jan/17 12:31", "Vokera", "Sabre", "24", "LPG", "827", "2004", "current", "2", "2", "1", "2", "0", "", "", "1", "2", "2", "24.0", "24.0", "", "", "83.1", "73.0", "", "51.3", "", "2", "0", "", "104", "1", "2", "125", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "84.9", "83.8", "", "", "", "", "84.0"]} -{"pcdb_id": 9987, "brand_name": "Sabre", "model_name": "24", "model_qualifier": "", "winter_efficiency_pct": 81.4, "summer_efficiency_pct": 71.3, "comparative_hot_water_efficiency_pct": 50.1, "output_kw_max": 24.0, "final_year_of_manufacture": null, "raw": ["009987", "000011", "0", "2006/Jan/17 12:31", "Vokera", "Sabre", "24", "", "826", "2004", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "24.0", "24.0", "", "", "81.4", "71.3", "", "50.1", "", "2", "", "", "104", "1", "2", "125", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "83.3", "82.3", "", "", "", "", "82.4"]} -{"pcdb_id": 9988, "brand_name": "Sabre", "model_name": "28", "model_qualifier": "", "winter_efficiency_pct": 81.3, "summer_efficiency_pct": 71.2, "comparative_hot_water_efficiency_pct": 50.1, "output_kw_max": 28.0, "final_year_of_manufacture": null, "raw": ["009988", "000011", "0", "2006/Jan/17 12:31", "Vokera", "Sabre", "28", "", "828", "2004", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "28.0", "28.0", "", "", "81.3", "71.2", "", "50.1", "", "2", "", "", "104", "1", "2", "125", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "83.3", "82.2", "", "", "", "", "82.4"]} -{"pcdb_id": 9989, "brand_name": "Glow-worm", "model_name": "30cxi", "model_qualifier": "", "winter_efficiency_pct": 90.1, "summer_efficiency_pct": 81.5, "comparative_hot_water_efficiency_pct": 57.3, "output_kw_max": 22.94, "final_year_of_manufacture": null, "raw": ["009989", "000207", "0", "2015/Jul/14 11:39", "Hepworth Heating", "Glow-worm", "30cxi", "", "GC 47-047-24", "2002", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "22.94", "22.94", "", "", "90.1", "81.5", "", "57.3", "", "2", "0", "", "104", "1", "2", "180", "15", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.1", "99.0", "", "", "", "", "97.3"]} -{"pcdb_id": 9990, "brand_name": "Glow-worm", "model_name": "30hxi", "model_qualifier": "", "winter_efficiency_pct": 90.0, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 59.2, "output_kw_max": 28.17, "final_year_of_manufacture": null, "raw": ["009990", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "30hxi", "", "GC 41-047-64", "2002", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "28.17", "28.17", "", "", "90.0", "81.0", "", "59.2", "", "2", "0", "", "102", "1", "2", "60", "15", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.8", "99.0", "", "", "", "", "97.3"]} -{"pcdb_id": 9991, "brand_name": "Firebird", "model_name": "Heatpac 70", "model_qualifier": "", "winter_efficiency_pct": 85.0, "summer_efficiency_pct": 73.3, "comparative_hot_water_efficiency_pct": 53.6, "output_kw_max": 20.52, "final_year_of_manufacture": 2013, "raw": ["009991", "000047", "0", "2018/Jan/03 14:39", "Firebird Boilers", "Firebird", "Heatpac 70", "", "", "2004", "2013", "4", "1", "2", "1", "0", "", "", "1", "1", "1", "14.65", "20.52", "", "", "85.0", "73.3", "", "53.6", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.5", "84.6", "", "", "", "", "84.8"]} -{"pcdb_id": 9992, "brand_name": "Firebird", "model_name": "S (White Cased) 70 System", "model_qualifier": "", "winter_efficiency_pct": 85.0, "summer_efficiency_pct": 73.3, "comparative_hot_water_efficiency_pct": 53.6, "output_kw_max": 20.52, "final_year_of_manufacture": 2013, "raw": ["009992", "000047", "0", "2018/Jan/03 14:41", "Firebird Boilers", "Firebird", "S (White Cased) 70 System", "", "", "2004", "2013", "4", "1", "1", "1", "0", "", "", "1", "2", "1", "14.65", "20.52", "", "", "85.0", "73.3", "", "53.6", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.5", "84.6", "", "", "", "", "84.8"]} -{"pcdb_id": 9993, "brand_name": "Firebird", "model_name": "Heatpac 70 System", "model_qualifier": "", "winter_efficiency_pct": 85.0, "summer_efficiency_pct": 73.3, "comparative_hot_water_efficiency_pct": 53.6, "output_kw_max": 20.52, "final_year_of_manufacture": 2013, "raw": ["009993", "000047", "0", "2018/Jan/03 14:43", "Firebird Boilers", "Firebird", "Heatpac 70 System", "", "", "2004", "2013", "4", "1", "2", "1", "0", "", "", "1", "1", "1", "14.65", "20.52", "", "", "85.0", "73.3", "", "53.6", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.5", "84.6", "", "", "", "", "84.8"]} -{"pcdb_id": 9994, "brand_name": "Firebird", "model_name": "Heatpac 90-120 System", "model_qualifier": "", "winter_efficiency_pct": 86.4, "summer_efficiency_pct": 74.7, "comparative_hot_water_efficiency_pct": 54.6, "output_kw_max": 35.17, "final_year_of_manufacture": 2013, "raw": ["009994", "000047", "0", "2018/Jan/03 14:44", "Firebird Boilers", "Firebird", "Heatpac 90-120 System", "", "", "2004", "2013", "4", "1", "2", "1", "0", "", "", "1", "1", "1", "26.38", "35.17", "", "", "86.4", "74.7", "", "54.6", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.4", "86.7", "", "", "", "", "86.6"]} -{"pcdb_id": 9995, "brand_name": "Firebird", "model_name": "S (White Cased) 90-120 System", "model_qualifier": "", "winter_efficiency_pct": 86.4, "summer_efficiency_pct": 74.7, "comparative_hot_water_efficiency_pct": 54.6, "output_kw_max": 35.17, "final_year_of_manufacture": 2013, "raw": ["009995", "000047", "0", "2018/Jan/03 14:48", "Firebird Boilers", "Firebird", "S (White Cased) 90-120 System", "", "", "2004", "2013", "4", "1", "1", "1", "0", "", "", "1", "2", "1", "26.38", "35.17", "", "", "86.4", "74.7", "", "54.6", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.4", "86.7", "", "", "", "", "86.6"]} -{"pcdb_id": 9996, "brand_name": "Ferroli", "model_name": "SYS 10-23", "model_qualifier": "", "winter_efficiency_pct": 79.8, "summer_efficiency_pct": 69.7, "comparative_hot_water_efficiency_pct": 50.9, "output_kw_max": 23.3, "final_year_of_manufacture": 2006, "raw": ["009996", "000097", "0", "2012/Mar/27 10:12", "Ferroli SpA", "Ferroli", "SYS 10-23", "", "", "2003", "2006", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "9.7", "23.3", "", "", "79.8", "69.7", "", "50.9", "", "2", "", "", "101", "1", "1", "125", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.0", "80.7", "", "", "", "", "81.0"]} -{"pcdb_id": 9997, "brand_name": "Worcester", "model_name": "Greenstar R", "model_qualifier": "29 HE Conventional", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 27.7, "final_year_of_manufacture": 2006, "raw": ["009997", "000035", "0", "2020/Sep/04 08:07", "Worcester Heat Systems", "Worcester", "Greenstar R", "29 HE Conventional", "ZB 11-28 HE", "2003", "2006", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "27.7", "27.7", "", "", "89.1", "80.1", "", "58.5", "", "2", "1", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.9", "98.9", "", "", "", "", "97.4"]} -{"pcdb_id": 9998, "brand_name": "Worcester", "model_name": "Greenstar R", "model_qualifier": "40 HE Conventional", "winter_efficiency_pct": 89.3, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 58.7, "output_kw_max": 40.0, "final_year_of_manufacture": 2006, "raw": ["009998", "000035", "0", "2020/Sep/04 08:07", "Worcester Heat Systems", "Worcester", "Greenstar R", "40 HE Conventional", "ZB 14-40 HE", "2003", "2006", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "40.0", "40.0", "", "", "89.3", "80.3", "", "58.7", "", "2", "1", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.8", "99.8", "", "", "", "", "97.9"]} -{"pcdb_id": 9999, "brand_name": "Worcester", "model_name": "Greenstar R", "model_qualifier": "25 HE Combi", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.4, "comparative_hot_water_efficiency_pct": 56.6, "output_kw_max": 27.5, "final_year_of_manufacture": 2006, "raw": ["009999", "000035", "0", "2020/Sep/04 08:07", "Worcester Heat Systems", "Worcester", "Greenstar R", "25 HE Combi", "ZWB 11-25 HE", "2003", "2006", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "27.5", "27.5", "", "", "89.0", "80.4", "", "56.6", "", "2", "1", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.9", "98.6", "", "", "", "", "97.2"]} -{"pcdb_id": 10000, "brand_name": "Worcester", "model_name": "Greenstar R", "model_qualifier": "28 HE System", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 27.7, "final_year_of_manufacture": 2006, "raw": ["010000", "000035", "0", "2020/Sep/04 08:07", "Worcester Heat Systems", "Worcester", "Greenstar R", "28 HE System", "ZB 11-28 HE", "2003", "2006", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "27.7", "27.7", "", "", "89.1", "80.1", "", "58.5", "", "2", "1", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.9", "98.9", "", "", "", "", "97.4"]} -{"pcdb_id": 10001, "brand_name": "Worcester", "model_name": "Greenstar R", "model_qualifier": "30 HE Combi", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 56.6, "output_kw_max": 29.5, "final_year_of_manufacture": 2006, "raw": ["010001", "000035", "0", "2020/Sep/04 08:07", "Worcester Heat Systems", "Worcester", "Greenstar R", "30 HE Combi", "ZWB 11-30 HE", "2003", "2006", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "29.5", "29.5", "", "", "89.1", "80.5", "", "56.6", "", "2", "1", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.9", "98.9", "", "", "", "", "97.4"]} -{"pcdb_id": 10002, "brand_name": "Worcester", "model_name": "Greenstar R", "model_qualifier": "30 HE Plus Combi", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 56.6, "output_kw_max": 29.5, "final_year_of_manufacture": 2006, "raw": ["010002", "000035", "0", "2020/Sep/04 08:07", "Worcester Heat Systems", "Worcester", "Greenstar R", "30 HE Plus Combi", "ZWBR 11-30 HE", "2003", "2006", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "29.5", "29.5", "", "", "89.1", "80.5", "", "56.6", "", "2", "1", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.9", "98.9", "", "", "", "", "97.4"]} -{"pcdb_id": 10003, "brand_name": "Worcester", "model_name": "Greenstar R", "model_qualifier": "35 HE plus Combi", "winter_efficiency_pct": 89.9, "summer_efficiency_pct": 81.3, "comparative_hot_water_efficiency_pct": 57.2, "output_kw_max": 35.5, "final_year_of_manufacture": 2006, "raw": ["010003", "000035", "0", "2020/Sep/04 08:07", "Worcester Heat Systems", "Worcester", "Greenstar R", "35 HE plus Combi", "ZWBR 14-35 HE", "2003", "2006", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "35.5", "35.5", "", "", "89.9", "81.3", "", "57.2", "", "2", "1", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.4", "101.1", "", "", "", "", "99.1"]} -{"pcdb_id": 10004, "brand_name": "Worcester", "model_name": "Greenstar R", "model_qualifier": "40 HE Plus Combi", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.4, "comparative_hot_water_efficiency_pct": 56.5, "output_kw_max": 40.0, "final_year_of_manufacture": 2006, "raw": ["010004", "000035", "0", "2020/Sep/04 08:07", "Worcester Heat Systems", "Worcester", "Greenstar R", "40 HE Plus Combi", "ZB 14-40 HE", "2003", "2006", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "40.0", "40.0", "", "", "89.0", "80.4", "", "56.5", "", "2", "1", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.8", "98.9", "", "", "", "", "97.2"]} -{"pcdb_id": 10005, "brand_name": "British Gas", "model_name": "RD 428", "model_qualifier": "", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 27.7, "final_year_of_manufacture": null, "raw": ["010005", "000035", "0", "2012/Mar/27 10:12", "Worcester Heat Systems", "British Gas", "RD 428", "", "ZB 11-18 RD", "2003", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "27.7", "27.7", "", "", "89.1", "80.1", "", "58.5", "", "2", "1", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.9", "98.9", "", "", "", "", "97.4"]} -{"pcdb_id": 10006, "brand_name": "Nefit Buderus Ltd", "model_name": "Boulter Buderus", "model_qualifier": "600-28C", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 56.5, "output_kw_max": 23.0, "final_year_of_manufacture": null, "raw": ["010006", "000041", "0", "2013/Jun/25 14:36", "Nefit Buderus", "Nefit Buderus Ltd", "Boulter Buderus", "600-28C", "47-110-02", "2003", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "23", "23", "", "", "88.9", "80.3", "", "56.5", "", "2", "", "", "104", "1", "2", "120", "6.5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.2", "99.1", "", "", "", "", "97.0"]} -{"pcdb_id": 10007, "brand_name": "Ariston", "model_name": "Microgenus II 24 MFFI", "model_qualifier": "", "winter_efficiency_pct": 82.9, "summer_efficiency_pct": 72.8, "comparative_hot_water_efficiency_pct": 51.2, "output_kw_max": 24.8, "final_year_of_manufacture": 2007, "raw": ["010007", "000080", "0", "2007/Nov/07 09:11", "Merloni TermoSanitari SpA", "Ariston", "Microgenus II 24 MFFI", "", "", "2004", "2007", "2", "2", "1", "2", "0", "", "", "1", "2", "2", "24.8", "24.8", "", "", "82.9", "72.8", "", "51.2", "", "2", "1", "", "104", "1", "2", "120", "7", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "86.3", "83.5", "", "", "", "", "84.1"]} -{"pcdb_id": 10008, "brand_name": "Ariston", "model_name": "Microgenus II 28 MFFI", "model_qualifier": "", "winter_efficiency_pct": 82.3, "summer_efficiency_pct": 72.2, "comparative_hot_water_efficiency_pct": 50.8, "output_kw_max": 28.0, "final_year_of_manufacture": 2007, "raw": ["010008", "000080", "0", "2007/Nov/07 09:13", "Merloni TermoSanitari SpA", "Ariston", "Microgenus II 28 MFFI", "", "", "2004", "2007", "2", "2", "1", "2", "0", "", "", "1", "2", "2", "28", "28", "", "", "82.3", "72.2", "", "50.8", "", "2", "1", "", "104", "1", "2", "140", "7", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "85.8", "82.3", "", "", "", "", "83.0"]} -{"pcdb_id": 10009, "brand_name": "Ariston", "model_name": "Microgenus II 31 MFFI", "model_qualifier": "", "winter_efficiency_pct": 82.6, "summer_efficiency_pct": 72.5, "comparative_hot_water_efficiency_pct": 51.0, "output_kw_max": 31.1, "final_year_of_manufacture": 2007, "raw": ["010009", "000080", "0", "2007/Nov/07 09:12", "Merloni TermoSanitari SpA", "Ariston", "Microgenus II 31 MFFI", "", "", "2004", "2007", "2", "2", "1", "2", "0", "", "", "1", "2", "2", "31.1", "31.1", "", "", "82.6", "72.5", "", "51.0", "", "2", "1", "", "104", "1", "2", "140", "7", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "85.5", "82.9", "", "", "", "", "83.4"]} -{"pcdb_id": 10010, "brand_name": "Ariston", "model_name": "Microgenus II 24 MFFI", "model_qualifier": "", "winter_efficiency_pct": 81.1, "summer_efficiency_pct": 71.0, "comparative_hot_water_efficiency_pct": 49.9, "output_kw_max": 24.8, "final_year_of_manufacture": 2007, "raw": ["010010", "000080", "0", "2007/Nov/07 09:11", "Merloni TermoSanitari SpA", "Ariston", "Microgenus II 24 MFFI", "", "GC No 47-116-25", "2004", "2007", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "24.8", "24.8", "", "", "81.1", "71.0", "", "49.9", "", "2", "", "", "104", "1", "2", "120", "7", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "84.4", "81.7", "", "", "", "", "82.2"]} -{"pcdb_id": 10011, "brand_name": "Ariston", "model_name": "Microgenus II 28 MFFI", "model_qualifier": "", "winter_efficiency_pct": 80.5, "summer_efficiency_pct": 70.4, "comparative_hot_water_efficiency_pct": 49.5, "output_kw_max": 28.0, "final_year_of_manufacture": 2007, "raw": ["010011", "000080", "0", "2007/Nov/07 09:13", "Merloni TermoSanitari SpA", "Ariston", "Microgenus II 28 MFFI", "", "GC No 47-116-26", "2004", "2007", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "28", "28", "", "", "80.5", "70.4", "", "49.5", "", "2", "", "", "104", "1", "2", "140", "7", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "84.0", "80.5", "", "", "", "", "81.2"]} -{"pcdb_id": 10012, "brand_name": "Ariston", "model_name": "Microgenus II 31 MFFI", "model_qualifier": "", "winter_efficiency_pct": 80.8, "summer_efficiency_pct": 70.7, "comparative_hot_water_efficiency_pct": 49.7, "output_kw_max": 31.1, "final_year_of_manufacture": 2007, "raw": ["010012", "000080", "0", "2007/Nov/07 09:12", "Merloni TermoSanitari SpA", "Ariston", "Microgenus II 31 MFFI", "", "GC No 47-116-27", "2004", "2007", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "31.1", "31.1", "", "", "80.8", "70.7", "", "49.7", "", "2", "", "", "104", "1", "2", "140", "7", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "83.6", "81.1", "", "", "", "", "81.6"]} -{"pcdb_id": 10013, "brand_name": "HRM Boilers", "model_name": "Weybourne", "model_qualifier": "70/95", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 27.8, "final_year_of_manufacture": null, "raw": ["010013", "000098", "0", "2012/Mar/27 10:12", "HRM Boilers", "HRM Boilers", "Weybourne", "70/95", "", "2003", "current", "4", "1", "1", "1", "0", "", "", "1", "3", "2", "20", "27.8", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "140", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.7", "87.3", "", "", "", "", "87.4"]} -{"pcdb_id": 10014, "brand_name": "HRM Boilers", "model_name": "Weybourne", "model_qualifier": "50/70", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 20.0, "final_year_of_manufacture": null, "raw": ["010014", "000098", "0", "2012/Mar/27 10:12", "HRM Boilers", "HRM Boilers", "Weybourne", "50/70", "", "2003", "current", "4", "1", "1", "1", "0", "", "", "1", "3", "2", "15", "20", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "140", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.8", "87.7", "", "", "", "", "87.7"]} -{"pcdb_id": 10015, "brand_name": "HRM Boilers", "model_name": "Wallstar System", "model_qualifier": "15/20 System 12", "winter_efficiency_pct": 86.4, "summer_efficiency_pct": 74.7, "comparative_hot_water_efficiency_pct": 54.6, "output_kw_max": 20.0, "final_year_of_manufacture": null, "raw": ["010015", "000098", "0", "2012/Mar/27 10:12", "HRM Boilers", "HRM Boilers", "Wallstar System", "15/20 System 12", "", "2003", "current", "4", "2", "1", "1", "0", "", "", "1", "2", "2", "15", "20", "", "", "86.4", "74.7", "", "54.6", "", "2", "", "", "201", "1", "1", "215", "75", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.6", "86.6", "", "", "", "", "86.6"]} -{"pcdb_id": 10016, "brand_name": "Evo", "model_name": "HE 16", "model_qualifier": "HE16", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 14.6, "final_year_of_manufacture": null, "raw": ["010016", "000008", "0", "2012/Mar/27 10:12", "Ideal Boilers", "Evo", "HE 16", "HE16", "", "2003", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "14.6", "14.6", "", "", "89.0", "80.0", "", "58.4", "", "2", "", "", "102", "1", "2", "38", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.5", "99.0", "", "", "", "", "97.0"]} -{"pcdb_id": 10017, "brand_name": "Evo", "model_name": "HE 19", "model_qualifier": "HE19", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 18.2, "final_year_of_manufacture": null, "raw": ["010017", "000008", "0", "2012/Mar/27 10:12", "Ideal Boilers", "Evo", "HE 19", "HE19", "", "2003", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18.2", "18.2", "", "", "88.7", "79.7", "", "58.2", "", "2", "", "", "102", "1", "2", "148", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.2", "98.5", "", "", "", "", "96.5"]} -{"pcdb_id": 10018, "brand_name": "Evo", "model_name": "HE 22", "model_qualifier": "HE22", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 23.4, "final_year_of_manufacture": null, "raw": ["010018", "000008", "0", "2012/Mar/27 10:12", "Ideal Boilers", "Evo", "HE 22", "HE22", "", "2003", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "23.4", "23.4", "", "", "88.1", "79.1", "", "57.8", "", "2", "", "", "102", "1", "2", "38", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "97.1", "", "", "", "", "95.4"]} -{"pcdb_id": 10019, "brand_name": "Evo", "model_name": "HE C22/24", "model_qualifier": "HE C 22/24", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 55.9, "output_kw_max": 23.4, "final_year_of_manufacture": null, "raw": ["010019", "000008", "0", "2006/Jan/17 12:31", "Ideal Boilers", "Evo", "HE C22/24", "HE C 22/24", "", "2003", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "23.4", "23.4", "", "", "88.1", "79.5", "", "55.9", "", "2", "", "", "104", "1", "2", "148", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "97.1", "", "", "", "", "95.4"]} -{"pcdb_id": 10020, "brand_name": "Evo", "model_name": "HE C22/35", "model_qualifier": "HE C22/35", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 55.9, "output_kw_max": 23.4, "final_year_of_manufacture": null, "raw": ["010020", "000008", "0", "2006/Jan/17 12:31", "Ideal Boilers", "Evo", "HE C22/35", "HE C22/35", "", "2003", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "23.4", "23.4", "", "", "88.1", "79.5", "", "55.9", "", "2", "", "", "104", "1", "2", "148", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "97.1", "", "", "", "", "95.4"]} -{"pcdb_id": 10021, "brand_name": "DD Heating", "model_name": "Heatline", "model_qualifier": "S20S Compact", "winter_efficiency_pct": 80.4, "summer_efficiency_pct": 69.7, "comparative_hot_water_efficiency_pct": 50.9, "output_kw_max": 21.1, "final_year_of_manufacture": 2007, "raw": ["010021", "000215", "0", "2012/Mar/27 10:12", "Turk Demir Dokum Fab AS", "DD Heating", "Heatline", "S20S Compact", "", "2003", "2007", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "21.1", "21.1", "", "", "80.4", "69.7", "", "50.9", "", "2", "", "", "102", "1", "2", "159", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "83.9", "79.8", "", "", "", "", "80.6"]} -{"pcdb_id": 10022, "brand_name": "DD Heating", "model_name": "Heatline", "model_qualifier": "S24S Compact", "winter_efficiency_pct": 81.0, "summer_efficiency_pct": 70.3, "comparative_hot_water_efficiency_pct": 51.4, "output_kw_max": 25.1, "final_year_of_manufacture": 2007, "raw": ["010022", "000215", "0", "2012/Mar/27 10:12", "Turk Demir Dokum Fab AS", "DD Heating", "Heatline", "S24S Compact", "", "2003", "2007", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "25.1", "25.1", "", "", "81.0", "70.3", "", "51.4", "", "2", "", "", "102", "1", "2", "159", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "84.1", "81.2", "", "", "", "", "81.7"]} -{"pcdb_id": 10023, "brand_name": "DD Heating", "model_name": "Heatline", "model_qualifier": "S30S Compact", "winter_efficiency_pct": 80.1, "summer_efficiency_pct": 69.4, "comparative_hot_water_efficiency_pct": 50.7, "output_kw_max": 30.1, "final_year_of_manufacture": 2007, "raw": ["010023", "000215", "0", "2012/Mar/27 10:12", "Turk Demir Dokum Fab AS", "DD Heating", "Heatline", "S30S Compact", "", "2003", "2007", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "30.1", "30.1", "", "", "80.1", "69.4", "", "50.7", "", "2", "", "", "102", "1", "2", "159", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "84.3", "79.3", "", "", "", "", "80.2"]} -{"pcdb_id": 10024, "brand_name": "Ariston", "model_name": "Genus Plus 30 BFFI", "model_qualifier": "", "winter_efficiency_pct": 81.8, "summer_efficiency_pct": 72.7, "comparative_hot_water_efficiency_pct": 42.0, "output_kw_max": 30.0, "final_year_of_manufacture": 2007, "raw": ["010024", "000080", "0", "2024/Jan/31 10:17", "Chaffoteaux & Maury", "Ariston", "Genus Plus 30 BFFI", "", "GC No. 47-116-28", "2004", "2007", "2", "2", "1", "2", "0", "", "", "1", "2", "2", "30", "30", "", "", "81.8", "72.7", "", "42.0", "", "2", "1", "", "106", "1", "2", "150", "7", "2", "1", "0", "50", "0", "20", "5", "70", "0.68", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "84.6", "80.8", "", "", "", "", "81.5"]} -{"pcdb_id": 10025, "brand_name": "Ariston", "model_name": "Genus Plus 30 BFFI", "model_qualifier": "", "winter_efficiency_pct": 80.0, "summer_efficiency_pct": 70.9, "comparative_hot_water_efficiency_pct": 40.9, "output_kw_max": 30.0, "final_year_of_manufacture": 2007, "raw": ["010025", "000080", "0", "2024/Jan/31 10:17", "Chaffoteaux et Maury", "Ariston", "Genus Plus 30 BFFI", "", "GC No. 47-116-28", "2004", "2007", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "30", "30", "", "", "80.0", "70.9", "", "40.9", "", "2", "", "", "106", "1", "2", "150", "7", "2", "1", "0", "50", "0", "20", "5", "70", "0.68", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.8", "79.0", "", "", "", "", "79.7"]} -{"pcdb_id": 10026, "brand_name": "Vokera", "model_name": "Synergy", "model_qualifier": "25e", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 78.9, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 24.7, "final_year_of_manufacture": 2010, "raw": ["010026", "000011", "0", "2012/Mar/27 10:12", "Vokera", "Vokera", "Synergy", "25e", "4109435", "2004", "2010", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24.7", "24.7", "", "", "87.9", "78.9", "", "57.7", "", "2", "", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.0", "96.2", "", "", "", "", "94.9"]} -{"pcdb_id": 10027, "brand_name": "Vokera", "model_name": "Syntesi", "model_qualifier": "25e", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 55.8, "output_kw_max": 24.7, "final_year_of_manufacture": 2010, "raw": ["010027", "000011", "0", "2010/Oct/21 11:08", "Vokera", "Vokera", "Syntesi", "25e", "4709446", "2003", "2010", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.7", "24.7", "", "", "87.9", "79.3", "", "55.8", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.0", "96.2", "", "", "", "", "94.9"]} -{"pcdb_id": 10028, "brand_name": "Baxi", "model_name": "100/2 HE Plus", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 30.2, "final_year_of_manufacture": 2006, "raw": ["010028", "000005", "0", "2012/Mar/27 10:12", "Baxi Potterton", "Baxi", "100/2 HE Plus", "", "GC No. 41-075-34", "2004", "2006", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "30.2", "30.2", "", "", "88.1", "79.1", "", "57.8", "", "2", "", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.4", "96.4", "", "", "", "", "95.1"]} -{"pcdb_id": 10029, "brand_name": "Baxi", "model_name": "System", "model_qualifier": "100 HE Plus", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 30.2, "final_year_of_manufacture": 2006, "raw": ["010029", "000005", "0", "2012/Mar/27 10:12", "Baxi Potterton", "Baxi", "System", "100 HE Plus", "GC No. 41-075-43", "2004", "2006", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "30.2", "30.2", "", "", "88.1", "79.1", "", "57.8", "", "2", "", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.4", "96.4", "", "", "", "", "95.1"]} -{"pcdb_id": 10030, "brand_name": "Baxi", "model_name": "Combi", "model_qualifier": "80 HE Plus", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 56.4, "output_kw_max": 24.1, "final_year_of_manufacture": 2006, "raw": ["010030", "000005", "0", "2009/Oct/26 16:58", "Baxi Potterton", "Baxi", "Combi", "80 HE Plus", "GC No. 41-075-16", "2004", "2006", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.1", "24.1", "", "", "88.8", "80.2", "", "56.4", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.5", "98.3", "", "", "", "", "96.6"]} -{"pcdb_id": 10031, "brand_name": "Baxi", "model_name": "Combi", "model_qualifier": "100 HE Plus", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 56.4, "output_kw_max": 30.2, "final_year_of_manufacture": 2006, "raw": ["010031", "000005", "0", "2009/Oct/26 16:57", "Baxi Potterton", "Baxi", "Combi", "100 HE Plus", "GC No. 41-075-15", "2004", "2006", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "30.2", "30.2", "", "", "88.8", "80.2", "", "56.4", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.4", "98.3", "", "", "", "", "96.6"]} -{"pcdb_id": 10032, "brand_name": "Baxi", "model_name": "Combi", "model_qualifier": "133 HE Plus", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 55.9, "output_kw_max": 30.1, "final_year_of_manufacture": 2007, "raw": ["010032", "000005", "0", "2010/Nov/19 09:01", "Baxi Potterton", "Baxi", "Combi", "133 HE Plus", "GC No. 41-075-14", "2004", "2007", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "30.1", "30.1", "", "", "88.1", "79.5", "", "55.9", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.2", "96.6", "", "", "", "", "95.2"]} -{"pcdb_id": 10033, "brand_name": "British Gas", "model_name": "330", "model_qualifier": "", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 31.0, "final_year_of_manufacture": null, "raw": ["010033", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "British Gas", "330", "", "GC 41-047-75", "2004", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "31.0", "31.0", "", "", "89.0", "80.0", "", "58.4", "", "2", "", "", "102", "1", "2", "60", "15", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.2", "98.8", "", "", "", "", "97.0"]} -{"pcdb_id": 10034, "brand_name": "Ferroli", "model_name": "Optimax", "model_qualifier": "25 S", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 24.7, "final_year_of_manufacture": 2008, "raw": ["010034", "000097", "0", "2012/Mar/27 10:12", "Ferroli SpA", "Ferroli", "Optimax", "25 S", "", "2003", "2008", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24.7", "24.7", "", "", "88.7", "79.7", "", "58.2", "", "2", "", "", "102", "1", "2", "130", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.4", "98.5", "", "", "", "", "96.6"]} -{"pcdb_id": 10035, "brand_name": "Ferroli", "model_name": "Optimax", "model_qualifier": "25 OV", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 24.7, "final_year_of_manufacture": 2017, "raw": ["010035", "000097", "0", "2017/Aug/07 16:58", "Ferroli SpA", "Ferroli", "Optimax", "25 OV", "", "2003", "2017", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24.7", "24.7", "", "", "88.7", "79.7", "", "58.2", "", "2", "", "", "102", "1", "2", "60", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.4", "98.5", "", "", "", "", "96.6"]} -{"pcdb_id": 10036, "brand_name": "Ferroli", "model_name": "Optimax", "model_qualifier": "25 C", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 56.3, "output_kw_max": 24.7, "final_year_of_manufacture": 2008, "raw": ["010036", "000097", "0", "2009/Apr/28 16:03", "Ferroli SpA", "Ferroli", "Optimax", "25 C", "", "2004", "2008", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.7", "24.7", "", "", "88.7", "80.1", "", "56.3", "", "2", "", "", "104", "1", "2", "140", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.4", "98.5", "", "", "", "", "96.6"]} -{"pcdb_id": 10038, "brand_name": "Nefit Buderus Ltd", "model_name": "Boulter Buderus", "model_qualifier": "600/28CP", "winter_efficiency_pct": 90.0, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 59.2, "output_kw_max": 23.0, "final_year_of_manufacture": null, "raw": ["010038", "000041", "0", "2013/Jun/25 14:37", "Nefit Buderus", "Nefit Buderus Ltd", "Boulter Buderus", "600/28CP", "87470174", "2002", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "23.0", "23.0", "", "", "90.0", "81.0", "", "59.2", "", "2", "0", "", "102", "1", "2", "120", "6.5", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.4", "99.2", "", "", "", "", "97.3"]} -{"pcdb_id": 10040, "brand_name": "Johnson & Starley", "model_name": "Reno", "model_qualifier": "HE25HP", "winter_efficiency_pct": 89.7, "summer_efficiency_pct": 80.7, "comparative_hot_water_efficiency_pct": 59.0, "output_kw_max": 27.85, "final_year_of_manufacture": null, "raw": ["010040", "000239", "0", "2012/Mar/27 10:12", "Johnson & Starley", "Johnson & Starley", "Reno", "HE25HP", "", "2004", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "27.85", "27.85", "", "", "89.7", "80.7", "", "59.0", "", "2", "0", "", "102", "1", "2", "35", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.1", "98.6", "", "", "", "", "96.8"]} -{"pcdb_id": 10041, "brand_name": "Johnson & Starley", "model_name": "Reno", "model_qualifier": "HE25H", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 25.0, "final_year_of_manufacture": null, "raw": ["010041", "000239", "0", "2012/Mar/27 10:12", "Johnson & Starley", "Johnson & Starley", "Reno", "HE25H", "87B074", "2004", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "25.0", "25.0", "", "", "88.5", "79.5", "", "58.1", "", "2", "", "", "102", "1", "2", "35", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.4", "98.0", "", "", "", "", "96.2"]} -{"pcdb_id": 10042, "brand_name": "Johnson & Starley", "model_name": "Reno", "model_qualifier": "HE25SP", "winter_efficiency_pct": 89.7, "summer_efficiency_pct": 80.7, "comparative_hot_water_efficiency_pct": 59.0, "output_kw_max": 25.0, "final_year_of_manufacture": null, "raw": ["010042", "000239", "0", "2012/Mar/27 10:12", "Johnson & Starley", "Johnson & Starley", "Reno", "HE25SP", "", "2004", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "25.0", "25.0", "", "", "89.7", "80.7", "", "59.0", "", "2", "0", "", "102", "1", "2", "145", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.1", "98.6", "", "", "", "", "96.8"]} -{"pcdb_id": 10043, "brand_name": "Johnson & Starley", "model_name": "Reno", "model_qualifier": "HE25S", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 25.0, "final_year_of_manufacture": null, "raw": ["010043", "000239", "0", "2012/Mar/27 10:12", "Johnson & Starley", "Johnson & Starley", "Reno", "HE25S", "", "2004", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "25.0", "25.0", "", "", "88.5", "79.5", "", "58.1", "", "2", "", "", "102", "1", "2", "145", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.4", "98.0", "", "", "", "", "96.2"]} -{"pcdb_id": 10044, "brand_name": "Johnson & Starley", "model_name": "Reno", "model_qualifier": "HE30CP", "winter_efficiency_pct": 89.7, "summer_efficiency_pct": 81.1, "comparative_hot_water_efficiency_pct": 57.1, "output_kw_max": 25.0, "final_year_of_manufacture": null, "raw": ["010044", "000239", "0", "2010/Sep/29 12:39", "Johnson & Starley", "Johnson & Starley", "Reno", "HE30CP", "", "2004", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "25.0", "25.0", "", "", "89.7", "81.1", "", "57.1", "", "2", "0", "", "104", "1", "2", "145", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.1", "98.6", "", "", "", "", "96.8"]} -{"pcdb_id": 10045, "brand_name": "Johnson & Starley", "model_name": "Reno", "model_qualifier": "HE30C", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 56.2, "output_kw_max": 25.0, "final_year_of_manufacture": null, "raw": ["010045", "000239", "0", "2009/Oct/28 09:38", "Johnson & Starley", "Johnson & Starley", "Reno", "HE30C", "", "2004", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "25.0", "25.0", "", "", "88.5", "79.9", "", "56.2", "", "2", "", "", "104", "1", "2", "145", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.4", "98.0", "", "", "", "", "96.2"]} -{"pcdb_id": 10046, "brand_name": "Biasi", "model_name": "Riva Compact HE", "model_qualifier": "M96.24SM/C", "winter_efficiency_pct": 86.2, "summer_efficiency_pct": 77.6, "comparative_hot_water_efficiency_pct": 54.5, "output_kw_max": 24.1, "final_year_of_manufacture": 2008, "raw": ["010046", "000208", "0", "2008/May/22 11:25", "Biasi (UK)", "Biasi", "Riva Compact HE", "M96.24SM/C", "", "2004", "2008", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24.10", "24.10", "", "", "86.2", "77.6", "", "54.5", "", "2", "1", "", "104", "1", "2", "140", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.8", "92.2", "", "", "", "", "91.5"]} -{"pcdb_id": 10047, "brand_name": "Biasi", "model_name": "Riva Compact HE", "model_qualifier": "M96.24SM/C", "winter_efficiency_pct": 85.2, "summer_efficiency_pct": 76.6, "comparative_hot_water_efficiency_pct": 53.9, "output_kw_max": 24.1, "final_year_of_manufacture": 2008, "raw": ["010047", "000208", "0", "2008/May/22 11:25", "Biasi (UK)", "Biasi", "Riva Compact HE", "M96.24SM/C", "47-970-23", "2004", "2008", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.10", "24.10", "", "", "85.2", "76.6", "", "53.9", "", "2", "", "", "104", "1", "2", "140", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "86.9", "90.2", "", "", "", "", "89.6"]} -{"pcdb_id": 10048, "brand_name": "Biasi", "model_name": "Riva Compact HE", "model_qualifier": "M96.28SM/C", "winter_efficiency_pct": 86.1, "summer_efficiency_pct": 77.5, "comparative_hot_water_efficiency_pct": 54.5, "output_kw_max": 27.9, "final_year_of_manufacture": 2008, "raw": ["010048", "000208", "0", "2008/May/22 11:31", "Biasi (UK)", "Biasi", "Riva Compact HE", "M96.28SM/C", "", "2004", "2008", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "27.9", "27.9", "", "", "86.1", "77.5", "", "54.5", "", "2", "1", "", "104", "1", "2", "160", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.7", "92.0", "", "", "", "", "91.4"]} -{"pcdb_id": 10049, "brand_name": "Biasi", "model_name": "Riva Compact HE", "model_qualifier": "M96.28SM/C", "winter_efficiency_pct": 85.1, "summer_efficiency_pct": 76.5, "comparative_hot_water_efficiency_pct": 53.8, "output_kw_max": 27.9, "final_year_of_manufacture": 2008, "raw": ["010049", "000208", "0", "2008/May/22 11:31", "Biasi (UK)", "Biasi", "Riva Compact HE", "M96.28SM/C", "47-970-24", "2004", "2008", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "27.9", "27.9", "", "", "85.1", "76.5", "", "53.8", "", "2", "", "", "104", "1", "2", "160", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "86.8", "90.0", "", "", "", "", "89.4"]} -{"pcdb_id": 10050, "brand_name": "Biasi", "model_name": "Riva Compact HE", "model_qualifier": "M96.28SR/C", "winter_efficiency_pct": 86.1, "summer_efficiency_pct": 77.1, "comparative_hot_water_efficiency_pct": 56.3, "output_kw_max": 27.9, "final_year_of_manufacture": 2008, "raw": ["010050", "000208", "0", "2012/Mar/27 10:12", "Biasi (UK)", "Biasi", "Riva Compact HE", "M96.28SR/C", "", "2004", "2008", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "27.9", "27.9", "", "", "86.1", "77.1", "", "56.3", "", "2", "1", "", "102", "1", "2", "160", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.7", "92.0", "", "", "", "", "91.4"]} -{"pcdb_id": 10051, "brand_name": "Biasi", "model_name": "Riva Compact HE", "model_qualifier": "M96.28SR/C", "winter_efficiency_pct": 85.1, "summer_efficiency_pct": 76.1, "comparative_hot_water_efficiency_pct": 55.6, "output_kw_max": 27.9, "final_year_of_manufacture": null, "raw": ["010051", "000208", "0", "2012/Mar/27 10:12", "Biasi (UK)", "Biasi", "Riva Compact HE", "M96.28SR/C", "41-970-12", "2004", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "27.9", "27.9", "", "", "85.1", "76.1", "", "55.6", "", "2", "", "", "102", "1", "2", "160", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "86.8", "90.0", "", "", "", "", "89.4"]} -{"pcdb_id": 10052, "brand_name": "Biasi", "model_name": "Garda HE", "model_qualifier": "M96.28SM/B", "winter_efficiency_pct": 86.1, "summer_efficiency_pct": 77.5, "comparative_hot_water_efficiency_pct": 54.5, "output_kw_max": 27.1, "final_year_of_manufacture": 2008, "raw": ["010052", "000208", "0", "2008/May/22 11:25", "Biasi (UK)", "Biasi", "Garda HE", "M96.28SM/B", "", "2004", "2008", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "27.10", "27.10", "", "", "86.1", "77.5", "", "54.5", "", "2", "1", "", "104", "1", "2", "160", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.7", "92.0", "", "", "", "", "91.4"]} -{"pcdb_id": 10053, "brand_name": "Biasi", "model_name": "Garda HE", "model_qualifier": "M96.28SM/B", "winter_efficiency_pct": 85.1, "summer_efficiency_pct": 76.5, "comparative_hot_water_efficiency_pct": 53.8, "output_kw_max": 27.1, "final_year_of_manufacture": 2008, "raw": ["010053", "000208", "0", "2008/May/22 11:26", "Biasi (UK)", "Biasi", "Garda HE", "M96.28SM/B", "47-970-26", "2004", "2008", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "27.10", "27.10", "", "", "85.1", "76.5", "", "53.8", "", "2", "", "", "104", "1", "2", "160", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "86.8", "90.0", "", "", "", "", "89.4"]} -{"pcdb_id": 10054, "brand_name": "Biasi", "model_name": "Garda HE", "model_qualifier": "M96.24SM/B", "winter_efficiency_pct": 86.2, "summer_efficiency_pct": 77.6, "comparative_hot_water_efficiency_pct": 54.5, "output_kw_max": 24.1, "final_year_of_manufacture": 2008, "raw": ["010054", "000208", "0", "2008/May/22 11:23", "Biasi (UK)", "Biasi", "Garda HE", "M96.24SM/B", "", "2004", "2008", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24.10", "24.10", "", "", "86.2", "77.6", "", "54.5", "", "2", "1", "", "104", "1", "2", "140", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.8", "92.2", "", "", "", "", "91.5"]} -{"pcdb_id": 10055, "brand_name": "Biasi", "model_name": "Garda HE", "model_qualifier": "M96.24SM/B", "winter_efficiency_pct": 85.2, "summer_efficiency_pct": 76.6, "comparative_hot_water_efficiency_pct": 53.9, "output_kw_max": 24.1, "final_year_of_manufacture": 2008, "raw": ["010055", "000208", "0", "2008/May/22 11:23", "Biasi (UK)", "Biasi", "Garda HE", "M96.24SM/B", "47-970-25", "2004", "2008", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.10", "24.10", "", "", "85.2", "76.6", "", "53.9", "", "2", "", "", "104", "1", "2", "140", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "86.9", "90.2", "", "", "", "", "89.6"]} -{"pcdb_id": 10056, "brand_name": "Biasi", "model_name": "Garda HE Silver", "model_qualifier": "M96.24SM/D", "winter_efficiency_pct": 86.2, "summer_efficiency_pct": 77.6, "comparative_hot_water_efficiency_pct": 54.5, "output_kw_max": 24.1, "final_year_of_manufacture": 2008, "raw": ["010056", "000208", "0", "2008/May/22 11:22", "Biasi (UK)", "Biasi", "Garda HE Silver", "M96.24SM/D", "", "2004", "2008", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24.10", "24.10", "", "", "86.2", "77.6", "", "54.5", "", "2", "1", "", "104", "1", "2", "140", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.8", "92.2", "", "", "", "", "91.5"]} -{"pcdb_id": 10057, "brand_name": "Biasi", "model_name": "Garda HE Silver", "model_qualifier": "M96.24SM/D", "winter_efficiency_pct": 85.2, "summer_efficiency_pct": 76.6, "comparative_hot_water_efficiency_pct": 53.9, "output_kw_max": 24.1, "final_year_of_manufacture": 2008, "raw": ["010057", "000208", "0", "2008/May/22 11:22", "Biasi (UK)", "Biasi", "Garda HE Silver", "M96.24SM/D", "47-970-27", "2004", "2008", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.10", "24.10", "", "", "85.2", "76.6", "", "53.9", "", "2", "", "", "104", "1", "2", "140", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "86.9", "90.2", "", "", "", "", "89.6"]} -{"pcdb_id": 10058, "brand_name": "Biasi", "model_name": "Garda HE Silver", "model_qualifier": "M96.28SM/D", "winter_efficiency_pct": 86.1, "summer_efficiency_pct": 77.5, "comparative_hot_water_efficiency_pct": 54.5, "output_kw_max": 27.9, "final_year_of_manufacture": 2008, "raw": ["010058", "000208", "0", "2008/May/22 11:28", "Biasi (UK)", "Biasi", "Garda HE Silver", "M96.28SM/D", "", "2004", "2008", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "27.90", "27.90", "", "", "86.1", "77.5", "", "54.5", "", "2", "1", "", "104", "1", "2", "160", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.7", "92.0", "", "", "", "", "91.4"]} -{"pcdb_id": 10059, "brand_name": "Biasi", "model_name": "Garda HE Silver", "model_qualifier": "M96.28SM/D", "winter_efficiency_pct": 85.1, "summer_efficiency_pct": 76.5, "comparative_hot_water_efficiency_pct": 53.8, "output_kw_max": 27.9, "final_year_of_manufacture": 2008, "raw": ["010059", "000208", "0", "2008/May/22 11:29", "Biasi (UK)", "Biasi", "Garda HE Silver", "M96.28SM/D", "47-970-28", "2004", "2008", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "27.90", "27.90", "", "", "85.1", "76.5", "", "53.8", "", "2", "", "", "104", "1", "2", "160", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "86.8", "90.0", "", "", "", "", "89.4"]} -{"pcdb_id": 10060, "brand_name": "Boulter", "model_name": "Buderus", "model_qualifier": "600/11R", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 11.0, "final_year_of_manufacture": null, "raw": ["010060", "000041", "0", "2012/Mar/27 10:12", "Boulter Buderus", "Boulter", "Buderus", "600/11R", "", "2000", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "11.0", "11.0", "", "", "88.6", "79.6", "", "58.2", "", "2", "", "", "102", "1", "2", "115", "6.5", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.1", "98.3", "", "", "", "", "96.4"]} -{"pcdb_id": 10061, "brand_name": "Boulter", "model_name": "Buderus", "model_qualifier": "600/19R", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 19.0, "final_year_of_manufacture": null, "raw": ["010061", "000041", "0", "2012/Mar/27 10:12", "Boulter Buderus", "Boulter", "Buderus", "600/19R", "", "2000", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "19.0", "19.0", "", "", "88.6", "79.6", "", "58.1", "", "2", "", "", "102", "1", "2", "115", "6.5", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.1", "98.2", "", "", "", "", "96.3"]} -{"pcdb_id": 10062, "brand_name": "Boulter", "model_name": "Buderus", "model_qualifier": "600/24R", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 24.0, "final_year_of_manufacture": null, "raw": ["010062", "000041", "0", "2012/Mar/27 10:12", "Boulter Buderus", "Boulter", "Buderus", "600/24R", "", "2000", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24.0", "24.0", "", "", "88.5", "79.5", "", "58.1", "", "2", "", "", "102", "1", "2", "115", "6.5", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "98.0", "", "", "", "", "96.1"]} -{"pcdb_id": 10063, "brand_name": "Fagor Electrodomesticos S.Coop", "model_name": "Morco FEB-24E Supercompact", "model_qualifier": "FEB-24EUK", "winter_efficiency_pct": 83.0, "summer_efficiency_pct": 72.9, "comparative_hot_water_efficiency_pct": 51.3, "output_kw_max": 23.7, "final_year_of_manufacture": null, "raw": ["010063", "000219", "0", "2013/Jun/25 14:31", "Fagor Electrodomesticos S.Coop", "Fagor Electrodomesticos S.Coop", "Morco FEB-24E Supercompact", "FEB-24EUK", "912110968", "2004", "current", "2", "2", "1", "2", "0", "", "", "1", "2", "2", "23.7", "23.7", "", "", "83.0", "72.9", "", "51.3", "", "2", "0", "", "104", "1", "2", "30", "4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "84.6", "87.0", "", "", "", "", "86.6"]} -{"pcdb_id": 10064, "brand_name": "Fagor Electrodomesticos S.Coop", "model_name": "Morco FEB-24E Supercompact", "model_qualifier": "FEB-24EUK Nat", "winter_efficiency_pct": 80.9, "summer_efficiency_pct": 70.8, "comparative_hot_water_efficiency_pct": 49.8, "output_kw_max": 23.7, "final_year_of_manufacture": null, "raw": ["010064", "000219", "0", "2013/Jun/25 14:31", "Fagor Electrodomesticos S.Coop", "Fagor Electrodomesticos S.Coop", "Morco FEB-24E Supercompact", "FEB-24EUK Nat", "912110959", "2004", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "23.7", "23.7", "", "", "80.9", "70.8", "", "49.8", "", "2", "", "", "104", "1", "2", "30", "4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.1", "82.2", "", "", "", "", "82.2"]} -{"pcdb_id": 10065, "brand_name": "Fagor Electrodomesticos S.Coop", "model_name": "FEB-24E Supercompact", "model_qualifier": "FEB-24EUK N", "winter_efficiency_pct": 80.9, "summer_efficiency_pct": 70.8, "comparative_hot_water_efficiency_pct": 49.8, "output_kw_max": 23.7, "final_year_of_manufacture": null, "raw": ["010065", "000219", "0", "2013/Jun/25 14:31", "Fagor Electrodomesticos S.Coop", "Fagor Electrodomesticos S.Coop", "FEB-24E Supercompact", "FEB-24EUK N", "912110940", "2004", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "23.7", "23.7", "", "", "80.9", "70.8", "", "49.8", "", "2", "", "", "104", "1", "2", "30", "4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.1", "82.2", "", "", "", "", "82.2"]} -{"pcdb_id": 10066, "brand_name": "Fagor Electrodomesticos S.Coop", "model_name": "FEB-24E Supercompact", "model_qualifier": "FEB-24EUK", "winter_efficiency_pct": 83.0, "summer_efficiency_pct": 72.9, "comparative_hot_water_efficiency_pct": 51.3, "output_kw_max": 23.7, "final_year_of_manufacture": null, "raw": ["010066", "000219", "0", "2013/Jun/25 14:31", "Fagor Electrodomesticos S.Coop", "Fagor Electrodomesticos S.Coop", "FEB-24E Supercompact", "FEB-24EUK", "912111002", "2004", "current", "2", "2", "1", "2", "0", "", "", "1", "2", "2", "23.7", "23.7", "", "", "83.0", "72.9", "", "51.3", "", "2", "0", "", "104", "1", "2", "30", "4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "84.6", "87.0", "", "", "", "", "86.6"]} -{"pcdb_id": 10067, "brand_name": "Fagor Electrodomesticos S.Coop", "model_name": "FEB-27E Supercompact", "model_qualifier": "FEB-27EUK N", "winter_efficiency_pct": 79.3, "summer_efficiency_pct": 69.2, "comparative_hot_water_efficiency_pct": 48.7, "output_kw_max": 27.0, "final_year_of_manufacture": null, "raw": ["010067", "000219", "0", "2013/Jun/25 14:32", "Fagor Electrodomesticos S.Coop", "Fagor Electrodomesticos S.Coop", "FEB-27E Supercompact", "FEB-27EUK N", "912110986", "2004", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "27", "27", "", "", "79.3", "69.2", "", "48.7", "", "2", "", "", "104", "1", "2", "30", "4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.5", "79.6", "", "", "", "", "79.9"]} -{"pcdb_id": 10068, "brand_name": "Ideal", "model_name": "isar", "model_qualifier": "HE30", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 55.9, "output_kw_max": 25.1, "final_year_of_manufacture": 2011, "raw": ["010068", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "isar", "HE30", "47-348-30", "2003", "2011", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "25.1", "25.1", "", "", "88.1", "79.5", "", "55.9", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "97.1", "", "", "", "", "95.4"]} -{"pcdb_id": 10069, "brand_name": "Evo", "model_name": "HE C22/30", "model_qualifier": "HE C22/30", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 55.9, "output_kw_max": 23.3, "final_year_of_manufacture": null, "raw": ["010069", "000008", "0", "2006/Jan/17 12:31", "Ideal Boilers", "Evo", "HE C22/30", "HE C22/30", "GC4734833", "2003", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "23.3", "23.3", "", "", "88.1", "79.5", "", "55.9", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "97.1", "", "", "", "", "95.4"]} -{"pcdb_id": 10070, "brand_name": "Evo", "model_name": "HE 12", "model_qualifier": "HE 12", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 12.7, "final_year_of_manufacture": null, "raw": ["010070", "000008", "0", "2012/Mar/27 10:12", "Ideal Boilers", "Evo", "HE 12", "HE 12", "GC4139796", "2004", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "12.7", "12.7", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "40", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.2", "96.8", "", "", "", "", "95.1"]} -{"pcdb_id": 10071, "brand_name": "Ideal", "model_name": "Icos", "model_qualifier": "HE 12", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 12.7, "final_year_of_manufacture": 2011, "raw": ["010071", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "Icos", "HE 12", "GC4139795", "2004", "2011", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "12.7", "12.7", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "40", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.2", "96.8", "", "", "", "", "95.1"]} -{"pcdb_id": 10072, "brand_name": "Ariston", "model_name": "Intesa TP 23 MFFI", "model_qualifier": "", "winter_efficiency_pct": 81.1, "summer_efficiency_pct": 71.0, "comparative_hot_water_efficiency_pct": 49.9, "output_kw_max": 24.8, "final_year_of_manufacture": 2007, "raw": ["010072", "000080", "0", "2007/Jun/18 09:23", "Merloni TermoSanitari SpA", "Ariston", "Intesa TP 23 MFFI", "", "GC No 47-116-32", "2004", "2007", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "24.8", "24.8", "", "", "81.1", "71.0", "", "49.9", "", "2", "", "", "104", "1", "2", "110", "7", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "84.4", "81.7", "", "", "", "", "82.2"]} -{"pcdb_id": 10073, "brand_name": "Ariston", "model_name": "Intesa TP 30 MFFI", "model_qualifier": "", "winter_efficiency_pct": 80.8, "summer_efficiency_pct": 70.7, "comparative_hot_water_efficiency_pct": 49.7, "output_kw_max": 36.6, "final_year_of_manufacture": 2007, "raw": ["010073", "000080", "0", "2007/Jun/18 09:23", "Merloni TermoSanitari SpA", "Ariston", "Intesa TP 30 MFFI", "", "GC No 47-116-33", "2004", "2007", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "36.6", "36.6", "", "", "80.8", "70.7", "", "49.7", "", "2", "", "", "104", "1", "2", "148", "7", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "83.6", "81.1", "", "", "", "", "81.6"]} -{"pcdb_id": 10074, "brand_name": "Ariston", "model_name": "Excalibur 23 MFFI", "model_qualifier": "Excalibur 80 MFFI", "winter_efficiency_pct": 81.0, "summer_efficiency_pct": 70.9, "comparative_hot_water_efficiency_pct": 49.9, "output_kw_max": 23.7, "final_year_of_manufacture": 2007, "raw": ["010074", "000080", "0", "2007/Jun/18 09:24", "Merloni TermoSanitari SpA", "Ariston", "Excalibur 23 MFFI", "Excalibur 80 MFFI", "GC No 47-116-30", "2004", "2007", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "23.7", "23.7", "", "", "81.0", "70.9", "", "49.9", "", "2", "", "", "104", "1", "2", "135", "7", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "83.3", "81.5", "", "", "", "", "81.9"]} -{"pcdb_id": 10075, "brand_name": "Ariston", "model_name": "Excalibur 27 MFFI", "model_qualifier": "Excalibur 100 MFFI", "winter_efficiency_pct": 80.3, "summer_efficiency_pct": 70.2, "comparative_hot_water_efficiency_pct": 49.3, "output_kw_max": 26.9, "final_year_of_manufacture": 2007, "raw": ["010075", "000080", "0", "2007/Jun/18 09:26", "Merloni TermoSanitari SpA", "Ariston", "Excalibur 27 MFFI", "Excalibur 100 MFFI", "GC No 47-116-31", "2004", "2007", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "26.9", "26.9", "", "", "80.3", "70.2", "", "49.3", "", "2", "", "", "104", "1", "2", "155", "7", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "", "", "0004", "", "", "", "", "", "", "", "", "82.9", "80.0", "", "", "", "", "80.6"]} -{"pcdb_id": 10076, "brand_name": "Hepworth Heating", "model_name": "EnviroPlus F24e", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 56.2, "output_kw_max": 25.1, "final_year_of_manufacture": null, "raw": ["010076", "000206", "0", "2009/Mar/31 14:32", "Hepworth Heating", "Hepworth Heating", "EnviroPlus F24e", "", "GC 47-920-45", "2004", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "25.1", "25.1", "", "", "88.5", "79.9", "", "56.2", "", "2", "", "", "104", "1", "2", "180", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "98.0", "", "", "", "", "96.2"]} -{"pcdb_id": 10077, "brand_name": "Gledhill", "model_name": "GulfStream A-Class", "model_qualifier": "12/SS", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 81.9, "comparative_hot_water_efficiency_pct": 48.9, "output_kw_max": 11.6, "final_year_of_manufacture": null, "raw": ["010077", "000072", "0", "2024/Jan/31 10:17", "Gledhill Water Storage", "Gledhill", "GulfStream A-Class", "12/SS", "", "2004", "current", "1", "1", "1", "2", "0", "", "", "2", "2", "2", "11.6", "11.6", "", "", "89.2", "81.9", "", "48.9", "", "2", "", "", "106", "1", "2", "", "", "1", "1", "0", "95", "0", "55", "2", "75", "60", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.2", "100.3", "", "", "", "", "97.8"]} -{"pcdb_id": 10078, "brand_name": "Gledhill", "model_name": "GulfStream A-Class", "model_qualifier": "12/OV", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 81.9, "comparative_hot_water_efficiency_pct": 48.9, "output_kw_max": 11.6, "final_year_of_manufacture": null, "raw": ["010078", "000072", "0", "2024/Jan/31 10:17", "Gledhill Water Storage", "Gledhill", "GulfStream A-Class", "12/OV", "", "2004", "current", "1", "1", "1", "2", "0", "", "", "2", "2", "2", "11.6", "11.6", "", "", "89.2", "81.9", "", "48.9", "", "2", "", "", "106", "1", "2", "", "", "1", "1", "0", "95", "0", "55", "2", "75", "60", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.2", "100.3", "", "", "", "", "97.8"]} -{"pcdb_id": 10079, "brand_name": "Gledhill", "model_name": "GulfStream A-Class", "model_qualifier": "20/SS", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 81.7, "comparative_hot_water_efficiency_pct": 48.8, "output_kw_max": 19.3, "final_year_of_manufacture": null, "raw": ["010079", "000072", "0", "2024/Jan/31 10:17", "Gledhill Water Storage", "Gledhill", "GulfStream A-Class", "20/SS", "", "2004", "current", "1", "1", "1", "2", "0", "", "", "2", "2", "2", "19.3", "19.3", "", "", "89.0", "81.7", "", "48.8", "", "2", "", "", "106", "1", "2", "", "", "1", "1", "0", "95", "0", "55", "2", "75", "60", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "86.9", "99.7", "", "", "", "", "97.2"]} -{"pcdb_id": 10080, "brand_name": "Gledhill", "model_name": "GulfStream A-Class", "model_qualifier": "20/OV", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 81.7, "comparative_hot_water_efficiency_pct": 48.8, "output_kw_max": 19.3, "final_year_of_manufacture": null, "raw": ["010080", "000072", "0", "2024/Jan/31 10:17", "Gledhill Water Storage", "Gledhill", "GulfStream A-Class", "20/OV", "", "2004", "current", "1", "1", "1", "2", "0", "", "", "2", "2", "2", "19.3", "19.3", "", "", "89.0", "81.7", "", "48.8", "", "2", "", "", "106", "1", "2", "", "", "1", "1", "0", "95", "0", "55", "2", "75", "60", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "86.9", "99.7", "", "", "", "", "97.2"]} -{"pcdb_id": 10081, "brand_name": "Gledhill", "model_name": "GulfStream A-Class", "model_qualifier": "30/SS", "winter_efficiency_pct": 87.6, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 48.0, "output_kw_max": 28.8, "final_year_of_manufacture": null, "raw": ["010081", "000072", "0", "2024/Jan/31 10:17", "Gledhill Water Storage", "Gledhill", "GulfStream A-Class", "30/SS", "", "2004", "current", "1", "1", "1", "2", "0", "", "", "2", "2", "2", "28.8", "28.8", "", "", "87.6", "80.3", "", "48.0", "", "2", "", "", "106", "1", "2", "", "", "1", "1", "0", "95", "0", "55", "2", "75", "60", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "86.6", "96.4", "", "", "", "", "94.5"]} -{"pcdb_id": 10082, "brand_name": "Gledhill", "model_name": "GulfStream A-Class", "model_qualifier": "30/OV", "winter_efficiency_pct": 87.6, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 48.0, "output_kw_max": 28.8, "final_year_of_manufacture": null, "raw": ["010082", "000072", "0", "2024/Jan/31 10:17", "Gledhill Water Storage", "Gledhill", "GulfStream A-Class", "30/OV", "", "2004", "current", "1", "1", "1", "2", "0", "", "", "2", "2", "2", "28.8", "28.8", "", "", "87.6", "80.3", "", "48.0", "", "2", "", "", "106", "1", "2", "", "", "1", "1", "0", "95", "0", "55", "2", "75", "60", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "86.6", "96.4", "", "", "", "", "94.5"]} -{"pcdb_id": 10083, "brand_name": "Boulter", "model_name": "Buderus", "model_qualifier": "600-24RP", "winter_efficiency_pct": 89.5, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 58.8, "output_kw_max": 24.0, "final_year_of_manufacture": null, "raw": ["010083", "000041", "0", "2012/Mar/27 10:12", "Boulter Buderus", "Boulter", "Buderus", "600-24RP", "", "2000", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "24.0", "24.0", "", "", "89.5", "80.5", "", "58.8", "", "2", "1", "", "102", "1", "2", "115", "6.5", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.9", "100.2", "", "", "", "", "98.2"]} -{"pcdb_id": 10084, "brand_name": "Boulter", "model_name": "Buderus", "model_qualifier": "600-24SP", "winter_efficiency_pct": 89.5, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 58.8, "output_kw_max": 22.0, "final_year_of_manufacture": 2007, "raw": ["010084", "000041", "0", "2012/Mar/27 10:12", "Boulter Buderus", "Boulter", "Buderus", "600-24SP", "7105050", "2000", "2007", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "22", "22", "", "", "89.5", "80.5", "", "58.8", "", "2", "1", "", "102", "1", "2", "115", "6.5", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.9", "100.2", "", "", "", "", "98.2"]} -{"pcdb_id": 10085, "brand_name": "Boulter", "model_name": "Buderus", "model_qualifier": "600-24CP", "winter_efficiency_pct": 89.5, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 58.8, "output_kw_max": 22.0, "final_year_of_manufacture": 2007, "raw": ["010085", "000041", "0", "2012/Mar/27 10:12", "Boulter Buderus", "Boulter", "Buderus", "600-24CP", "7105060", "2000", "2007", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "22.0", "22.0", "", "", "89.5", "80.5", "", "58.8", "", "2", "1", "", "102", "1", "2", "115", "6.5", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.9", "100.2", "", "", "", "", "98.2"]} -{"pcdb_id": 10086, "brand_name": "Boulter", "model_name": "Buderus", "model_qualifier": "600-19RP", "winter_efficiency_pct": 89.6, "summer_efficiency_pct": 80.6, "comparative_hot_water_efficiency_pct": 58.9, "output_kw_max": 19.0, "final_year_of_manufacture": null, "raw": ["010086", "000041", "0", "2012/Mar/27 10:12", "Boulter Buderus", "Boulter", "Buderus", "600-19RP", "", "2000", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "19", "19", "", "", "89.6", "80.6", "", "58.9", "", "2", "1", "", "102", "1", "2", "115", "6.5", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.1", "100.4", "", "", "", "", "98.4"]} -{"pcdb_id": 10087, "brand_name": "Boulter", "model_name": "Buderus", "model_qualifier": "600-19SP", "winter_efficiency_pct": 89.6, "summer_efficiency_pct": 80.6, "comparative_hot_water_efficiency_pct": 58.9, "output_kw_max": 17.4, "final_year_of_manufacture": 2007, "raw": ["010087", "000041", "0", "2012/Mar/27 10:12", "Boulter Buderus", "Boulter", "Buderus", "600-19SP", "7105040", "2000", "2007", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "17.4", "17.4", "", "", "89.6", "80.6", "", "58.9", "", "2", "1", "", "102", "1", "2", "115", "6.5", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.1", "100.4", "", "", "", "", "98.4"]} -{"pcdb_id": 10088, "brand_name": "Boulter", "model_name": "Buderus", "model_qualifier": "600-11RP", "winter_efficiency_pct": 89.6, "summer_efficiency_pct": 80.6, "comparative_hot_water_efficiency_pct": 58.9, "output_kw_max": 10.5, "final_year_of_manufacture": null, "raw": ["010088", "000041", "0", "2012/Mar/27 10:12", "Boulter Buderus", "Boulter", "Buderus", "600-11RP", "", "2000", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "10.5", "10.5", "", "", "89.6", "80.6", "", "58.9", "", "2", "1", "", "102", "1", "2", "115", "6.5", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.1", "100.5", "", "", "", "", "98.5"]} -{"pcdb_id": 10089, "brand_name": "Boulter", "model_name": "Buderus", "model_qualifier": "600-11SP", "winter_efficiency_pct": 90.1, "summer_efficiency_pct": 81.1, "comparative_hot_water_efficiency_pct": 59.3, "output_kw_max": 10.5, "final_year_of_manufacture": 2007, "raw": ["010089", "000041", "0", "2012/Mar/27 10:12", "Boulter Buderus", "Boulter", "Buderus", "600-11SP", "7105030", "2000", "2007", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "10.5", "10.5", "", "", "90.1", "81.1", "", "59.3", "", "2", "1", "", "102", "1", "2", "115", "6.5", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.3", "101.7", "", "", "", "", "99.5"]} -{"pcdb_id": 10090, "brand_name": "Boulter", "model_name": "Buderus", "model_qualifier": "800-43P", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 42.9, "final_year_of_manufacture": null, "raw": ["010090", "000041", "0", "2012/Mar/27 10:12", "Boulter Buderus", "Boulter", "Buderus", "800-43P", "", "1999", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "42.9", "42.9", "", "", "88.9", "79.9", "", "58.3", "", "2", "1", "", "102", "1", "2", "180", "8", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.1", "98.5", "", "", "", "", "96.9"]} -{"pcdb_id": 10091, "brand_name": "Boulter", "model_name": "Buderus", "model_qualifier": "800-29P", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 29.9, "final_year_of_manufacture": null, "raw": ["010091", "000041", "0", "2012/Mar/27 10:12", "Boulter Buderus", "Boulter", "Buderus", "800-29P", "", "1999", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "29.9", "29.9", "", "", "88.9", "79.9", "", "58.3", "", "2", "1", "", "102", "1", "2", "130", "8", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.8", "98.6", "", "", "", "", "97.0"]} -{"pcdb_id": 10092, "brand_name": "Boulter", "model_name": "Buderus", "model_qualifier": "800-24P", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 23.4, "final_year_of_manufacture": null, "raw": ["010092", "000041", "0", "2012/Mar/27 10:12", "Boulter Buderus", "Boulter", "Buderus", "800-24P", "", "1999", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "23.4", "23.4", "", "", "88.8", "79.8", "", "58.3", "", "2", "1", "", "102", "1", "2", "120", "8", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.6", "98.5", "", "", "", "", "96.8"]} -{"pcdb_id": 10093, "brand_name": "Alpha", "model_name": "CD50", "model_qualifier": "", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 49.6, "output_kw_max": 32.0, "final_year_of_manufacture": null, "raw": ["010093", "000001", "0", "2024/Jan/31 10:17", "Alpha Therm", "Alpha", "CD50", "", "", "2004", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "32", "32", "", "", "88.2", "81.0", "", "49.6", "", "2", "", "", "106", "1", "2", "140", "2", "2", "2", "0", "52", "0", "25", "5", "60", "0.97", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.1", "96.8", "", "", "", "", "95.3"]} -{"pcdb_id": 10095, "brand_name": "Boulter", "model_name": "Buderus", "model_qualifier": "500-28C", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.4, "comparative_hot_water_efficiency_pct": 56.5, "output_kw_max": 23.0, "final_year_of_manufacture": null, "raw": ["010095", "000041", "0", "2006/Jan/17 12:31", "Boulter Buderus", "Boulter", "Buderus", "500-28C", "87470220", "2004", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "23.0", "23.0", "", "", "89.0", "80.4", "", "56.5", "", "2", "", "", "104", "1", "2", "110", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "99.4", "", "", "", "", "97.2"]} -{"pcdb_id": 10096, "brand_name": "Boulter", "model_name": "Buderus", "model_qualifier": "500-28CP", "winter_efficiency_pct": 90.0, "summer_efficiency_pct": 81.4, "comparative_hot_water_efficiency_pct": 57.3, "output_kw_max": 23.0, "final_year_of_manufacture": null, "raw": ["010096", "000041", "0", "2006/Jan/17 12:31", "Boulter Buderus", "Boulter", "Buderus", "500-28CP", "", "2004", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "23.0", "23.0", "", "", "90.0", "81.4", "", "57.3", "", "2", "1", "", "104", "1", "2", "10", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.8", "101.6", "", "", "", "", "99.3"]} -{"pcdb_id": 10097, "brand_name": "Boulter", "model_name": "Buderus", "model_qualifier": "500 - 24S", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 23.0, "final_year_of_manufacture": null, "raw": ["010097", "000041", "0", "2012/Mar/27 10:12", "Boulter Buderus", "Boulter", "Buderus", "500 - 24S", "87470222", "2004", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "23", "23", "", "", "89.0", "80.0", "", "58.4", "", "2", "", "", "102", "1", "2", "110", "3", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "99.4", "", "", "", "", "97.2"]} -{"pcdb_id": 10098, "brand_name": "Boulter", "model_name": "Buderus", "model_qualifier": "500-24SP", "winter_efficiency_pct": 90.0, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 59.2, "output_kw_max": 23.0, "final_year_of_manufacture": null, "raw": ["010098", "000041", "0", "2012/Mar/27 10:12", "Boulter Buderus", "Boulter", "Buderus", "500-24SP", "", "2004", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "23", "23", "", "", "90.0", "81.0", "", "59.2", "", "2", "1", "", "102", "1", "2", "110", "3", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.8", "101.6", "", "", "", "", "99.3"]} -{"pcdb_id": 10099, "brand_name": "Sime", "model_name": "Format 30 HE LPG", "model_qualifier": "", "winter_efficiency_pct": 90.1, "summer_efficiency_pct": 81.5, "comparative_hot_water_efficiency_pct": 57.3, "output_kw_max": 27.3, "final_year_of_manufacture": 2018, "raw": ["010099", "000213", "0", "2018/Feb/26 17:04", "Fonderie Sime S.p.A.", "Sime", "Format 30 HE LPG", "", "", "2004", "2018", "2", "2", "1", "2", "0", "", "", "2", "3", "2", "27.3", "27.3", "", "", "90.1", "81.5", "", "57.3", "", "2", "1", "", "104", "1", "2", "50", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.2", "101.7", "", "", "", "", "99.5"]} -{"pcdb_id": 10100, "brand_name": "Sime", "model_name": "Format 30 HE", "model_qualifier": "", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 56.6, "output_kw_max": 27.3, "final_year_of_manufacture": 2018, "raw": ["010100", "000213", "0", "2018/Feb/26 17:04", "Fonderie Sime S.p.A.", "Sime", "Format 30 HE", "", "", "2004", "2018", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "27.3", "27.3", "", "", "89.1", "80.5", "", "56.6", "", "2", "", "", "104", "1", "2", "50", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.2", "99.5", "", "", "", "", "97.3"]} -{"pcdb_id": 10101, "brand_name": "Sime", "model_name": "Format System 25 HE LPG", "model_qualifier": "", "winter_efficiency_pct": 89.6, "summer_efficiency_pct": 80.6, "comparative_hot_water_efficiency_pct": 58.9, "output_kw_max": 22.7, "final_year_of_manufacture": 2018, "raw": ["010101", "000213", "0", "2018/Feb/28 17:01", "Fonderie Sime S.p.A.", "Sime", "Format System 25 HE LPG", "", "", "2004", "2018", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "22.7", "22.7", "", "", "89.6", "80.6", "", "58.9", "", "2", "1", "", "102", "1", "2", "50", "10", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.8", "100.6", "", "", "", "", "98.5"]} -{"pcdb_id": 10102, "brand_name": "Sime", "model_name": "Format System 25 HE", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 22.7, "final_year_of_manufacture": 2018, "raw": ["010102", "000213", "0", "2018/Feb/28 17:00", "Fonderie Sime S.p.A.", "Sime", "Format System 25 HE", "", "", "2004", "2018", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "22.7", "22.7", "", "", "88.6", "79.6", "", "58.1", "", "2", "", "", "102", "1", "2", "50", "10", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "98.4", "", "", "", "", "96.4"]} -{"pcdb_id": 10103, "brand_name": "Sime", "model_name": "Format 25 HE LPG", "model_qualifier": "", "winter_efficiency_pct": 89.6, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 57.0, "output_kw_max": 22.7, "final_year_of_manufacture": 2018, "raw": ["010103", "000213", "0", "2018/Feb/26 17:03", "Fonderie Sime S.p.A.", "Sime", "Format 25 HE LPG", "", "", "2004", "2018", "2", "2", "1", "2", "0", "", "", "2", "3", "2", "22.7", "22.7", "", "", "89.6", "81.0", "", "57.0", "", "2", "1", "", "104", "1", "2", "50", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.8", "100.6", "", "", "", "", "98.5"]} -{"pcdb_id": 10104, "brand_name": "Sime", "model_name": "Format 25 HE", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 56.3, "output_kw_max": 22.7, "final_year_of_manufacture": 2018, "raw": ["010104", "000213", "0", "2018/Feb/26 17:03", "Fonderie Sime S.p.A.", "Sime", "Format 25 HE", "", "", "2004", "2018", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "22.7", "22.7", "", "", "88.6", "80.0", "", "56.3", "", "2", "", "", "104", "1", "2", "50", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "98.4", "", "", "", "", "96.4"]} -{"pcdb_id": 10105, "brand_name": "Sime", "model_name": "Format System 30 HE LPG", "model_qualifier": "", "winter_efficiency_pct": 90.1, "summer_efficiency_pct": 81.1, "comparative_hot_water_efficiency_pct": 59.2, "output_kw_max": 27.3, "final_year_of_manufacture": 2018, "raw": ["010105", "000213", "0", "2018/Mar/05 14:05", "Fonderie Sime S.p.A.", "Sime", "Format System 30 HE LPG", "", "", "2004", "2018", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "27.3", "27.3", "", "", "90.1", "81.1", "", "59.2", "", "2", "1", "", "102", "1", "2", "50", "10", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.2", "101.7", "", "", "", "", "99.5"]} -{"pcdb_id": 10106, "brand_name": "Sime", "model_name": "Format System 30 HE", "model_qualifier": "", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 27.3, "final_year_of_manufacture": 2018, "raw": ["010106", "000213", "0", "2018/Mar/05 14:04", "Fonderie Sime S.p.A.", "Sime", "Format System 30 HE", "", "", "2004", "2018", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "27.3", "27.3", "", "", "89.1", "80.1", "", "58.5", "", "2", "", "", "102", "1", "2", "50", "10", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.2", "99.5", "", "", "", "", "97.3"]} -{"pcdb_id": 10107, "brand_name": "Baxi", "model_name": "Combi", "model_qualifier": "Instant 105 HE", "winter_efficiency_pct": 87.8, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 55.7, "output_kw_max": 29.6, "final_year_of_manufacture": 2008, "raw": ["010107", "000005", "0", "2010/Nov/19 09:02", "Baxi Potterton", "Baxi", "Combi", "Instant 105 HE", "", "2004", "2008", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "29.6", "29.6", "", "", "87.8", "79.2", "", "55.7", "", "2", "0", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "0", "", "0005", "", "", "", "", "", "", "", "", "89.5", "93.4", "", "", "", "", "92.7"]} -{"pcdb_id": 10108, "brand_name": "Baxi", "model_name": "Combi", "model_qualifier": "Instant 105 HE", "winter_efficiency_pct": 85.8, "summer_efficiency_pct": 77.2, "comparative_hot_water_efficiency_pct": 54.3, "output_kw_max": 29.6, "final_year_of_manufacture": 2008, "raw": ["010108", "000005", "0", "2010/Nov/19 09:02", "Baxi Potterton", "Baxi", "Combi", "Instant 105 HE", "GC No. 47-075-19", "2004", "2008", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "29.6", "29.6", "", "", "85.8", "77.2", "", "54.3", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "0", "", "0005", "", "", "", "", "", "", "", "", "87.6", "91.3", "", "", "", "", "90.6"]} -{"pcdb_id": 10109, "brand_name": "Baxi", "model_name": "Combi", "model_qualifier": "Instant 80 HE", "winter_efficiency_pct": 87.8, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 55.7, "output_kw_max": 24.0, "final_year_of_manufacture": 2008, "raw": ["010109", "000005", "0", "2010/Nov/19 09:02", "Baxi Potterton", "Baxi", "Combi", "Instant 80 HE", "", "2004", "2008", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24.0", "24.0", "", "", "87.8", "79.2", "", "55.7", "", "2", "0", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "0", "", "0005", "", "", "", "", "", "", "", "", "89.2", "93.7", "", "", "", "", "92.8"]} -{"pcdb_id": 10110, "brand_name": "Baxi", "model_name": "Combi", "model_qualifier": "Instant 80 HE", "winter_efficiency_pct": 85.8, "summer_efficiency_pct": 77.2, "comparative_hot_water_efficiency_pct": 54.3, "output_kw_max": 24.0, "final_year_of_manufacture": 2008, "raw": ["010110", "000005", "0", "2010/Nov/19 09:01", "Baxi Potterton", "Baxi", "Combi", "Instant 80 HE", "GC No. 47-075-17", "2004", "2008", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.0", "24.0", "", "", "85.8", "77.2", "", "54.3", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "0", "", "0005", "", "", "", "", "", "", "", "", "87.2", "91.5", "", "", "", "", "90.7"]} -{"pcdb_id": 10111, "brand_name": "Baxi", "model_name": "Combi", "model_qualifier": "105 HE", "winter_efficiency_pct": 87.8, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 55.7, "output_kw_max": 29.6, "final_year_of_manufacture": 2011, "raw": ["010111", "000005", "0", "2013/May/07 10:25", "Baxi Potterton", "Baxi", "Combi", "105 HE", "", "2004", "2011", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "29.6", "29.6", "", "", "87.8", "79.2", "", "55.7", "", "2", "0", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "", "", "0005", "", "", "", "", "", "", "", "", "89.5", "93.4", "", "", "", "", "92.7"]} -{"pcdb_id": 10112, "brand_name": "Baxi", "model_name": "Combi", "model_qualifier": "105 HE", "winter_efficiency_pct": 85.8, "summer_efficiency_pct": 77.2, "comparative_hot_water_efficiency_pct": 54.3, "output_kw_max": 29.6, "final_year_of_manufacture": 2011, "raw": ["010112", "000005", "0", "2013/May/07 10:25", "Baxi Potterton", "Baxi", "Combi", "105 HE", "GC No. 47-075-18", "2004", "2011", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "29.6", "29.6", "", "", "85.8", "77.2", "", "54.3", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "", "", "0005", "", "", "", "", "", "", "", "", "87.6", "91.3", "", "", "", "", "90.6"]} -{"pcdb_id": 10113, "brand_name": "Potterton", "model_name": "Performa System", "model_qualifier": "28 HE", "winter_efficiency_pct": 87.7, "summer_efficiency_pct": 78.7, "comparative_hot_water_efficiency_pct": 57.5, "output_kw_max": 28.0, "final_year_of_manufacture": 2011, "raw": ["010113", "000005", "0", "2013/May/07 10:25", "Baxi Potterton", "Potterton", "Performa System", "28 HE", "", "2004", "2011", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "28.0", "28.0", "", "", "87.7", "78.7", "", "57.5", "", "2", "0", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.4", "93.4", "", "", "", "", "92.6"]} -{"pcdb_id": 10114, "brand_name": "Potterton", "model_name": "Performa System", "model_qualifier": "28 HE", "winter_efficiency_pct": 85.7, "summer_efficiency_pct": 76.7, "comparative_hot_water_efficiency_pct": 56.0, "output_kw_max": 28.0, "final_year_of_manufacture": 2011, "raw": ["010114", "000005", "0", "2013/May/07 10:25", "Baxi Potterton", "Potterton", "Performa System", "28 HE", "GC No. 41-591-27", "2004", "2011", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "28.0", "28.0", "", "", "85.7", "76.7", "", "56.0", "", "2", "", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.4", "91.3", "", "", "", "", "90.5"]} -{"pcdb_id": 10115, "brand_name": "Potterton", "model_name": "Performa System", "model_qualifier": "24 HE", "winter_efficiency_pct": 87.8, "summer_efficiency_pct": 78.8, "comparative_hot_water_efficiency_pct": 57.6, "output_kw_max": 24.0, "final_year_of_manufacture": 2011, "raw": ["010115", "000005", "0", "2013/May/07 10:25", "Baxi Potterton", "Potterton", "Performa System", "24 HE", "", "2004", "2011", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "24.0", "24.0", "", "", "87.8", "78.8", "", "57.6", "", "2", "0", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.2", "93.7", "", "", "", "", "92.8"]} -{"pcdb_id": 10116, "brand_name": "Potterton", "model_name": "Performa System", "model_qualifier": "24 HE", "winter_efficiency_pct": 85.8, "summer_efficiency_pct": 76.8, "comparative_hot_water_efficiency_pct": 56.1, "output_kw_max": 24.0, "final_year_of_manufacture": 2011, "raw": ["010116", "000005", "0", "2013/May/07 10:26", "Baxi Potterton", "Potterton", "Performa System", "24 HE", "GC No. 41-591-26", "2004", "2011", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24.0", "24.0", "", "", "85.8", "76.8", "", "56.1", "", "2", "", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.2", "91.5", "", "", "", "", "90.7"]} -{"pcdb_id": 10117, "brand_name": "Potterton", "model_name": "Performa System", "model_qualifier": "18 HE", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 18.0, "final_year_of_manufacture": 2011, "raw": ["010117", "000005", "0", "2013/May/07 10:26", "Baxi Potterton", "Potterton", "Performa System", "18 HE", "", "2004", "2011", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "18.0", "18.0", "", "", "88.0", "79.0", "", "57.7", "", "2", "0", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.6", "94.4", "", "", "", "", "93.3"]} -{"pcdb_id": 10118, "brand_name": "Potterton", "model_name": "Performa System", "model_qualifier": "18 HE", "winter_efficiency_pct": 86.0, "summer_efficiency_pct": 77.0, "comparative_hot_water_efficiency_pct": 56.2, "output_kw_max": 18.0, "final_year_of_manufacture": 2011, "raw": ["010118", "000005", "0", "2013/May/07 10:26", "Baxi Potterton", "Potterton", "Performa System", "18 HE", "GC No. 41-591-25", "2004", "2011", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18.0", "18.0", "", "", "86.0", "77.0", "", "56.2", "", "2", "", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "86.6", "92.3", "", "", "", "", "91.2"]} -{"pcdb_id": 10119, "brand_name": "Potterton", "model_name": "Performa System", "model_qualifier": "12 HE", "winter_efficiency_pct": 87.6, "summer_efficiency_pct": 78.6, "comparative_hot_water_efficiency_pct": 57.4, "output_kw_max": 12.0, "final_year_of_manufacture": 2011, "raw": ["010119", "000005", "0", "2013/May/07 10:27", "Baxi Potterton", "Potterton", "Performa System", "12 HE", "", "2004", "2011", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "12", "12", "", "", "87.6", "78.6", "", "57.4", "", "2", "0", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.1", "93.6", "", "", "", "", "92.5"]} -{"pcdb_id": 10120, "brand_name": "Potterton", "model_name": "Performa System", "model_qualifier": "12 HE", "winter_efficiency_pct": 85.6, "summer_efficiency_pct": 76.6, "comparative_hot_water_efficiency_pct": 55.9, "output_kw_max": 12.0, "final_year_of_manufacture": 2011, "raw": ["010120", "000005", "0", "2013/May/07 10:27", "Baxi Potterton", "Potterton", "Performa System", "12 HE", "GC No. 41-591-24", "2004", "2011", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "12.0", "12.0", "", "", "85.6", "76.6", "", "55.9", "", "2", "", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "86.1", "91.5", "", "", "", "", "90.4"]} -{"pcdb_id": 10121, "brand_name": "Potterton", "model_name": "Performa", "model_qualifier": "30 HE", "winter_efficiency_pct": 87.8, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 55.7, "output_kw_max": 29.6, "final_year_of_manufacture": 2012, "raw": ["010121", "000005", "0", "2013/May/07 10:27", "Baxi Potterton", "Potterton", "Performa", "30 HE", "", "2004", "2012", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "29.6", "29.6", "", "", "87.8", "79.2", "", "55.7", "", "2", "0", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "", "", "0005", "", "", "", "", "", "", "", "", "89.5", "93.4", "", "", "", "", "92.7"]} -{"pcdb_id": 10122, "brand_name": "Potterton", "model_name": "Performa", "model_qualifier": "30 HE", "winter_efficiency_pct": 85.8, "summer_efficiency_pct": 77.2, "comparative_hot_water_efficiency_pct": 54.3, "output_kw_max": 29.6, "final_year_of_manufacture": 2012, "raw": ["010122", "000005", "0", "2013/May/07 10:27", "Baxi Potterton", "Potterton", "Performa", "30 HE", "GC No. 47-393-13", "2004", "2012", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "29.6", "29.6", "", "", "85.8", "77.2", "", "54.3", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "", "", "0005", "", "", "", "", "", "", "", "", "87.6", "91.3", "", "", "", "", "90.6"]} -{"pcdb_id": 10123, "brand_name": "Potterton", "model_name": "Performa", "model_qualifier": "24i HE", "winter_efficiency_pct": 87.8, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 55.7, "output_kw_max": 24.0, "final_year_of_manufacture": 2008, "raw": ["010123", "000005", "0", "2010/Nov/19 09:19", "Baxi Potterton", "Potterton", "Performa", "24i HE", "", "2004", "2008", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "87.8", "79.2", "", "55.7", "", "2", "0", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "", "", "0005", "", "", "", "", "", "", "", "", "89.2", "93.7", "", "", "", "", "92.8"]} -{"pcdb_id": 10124, "brand_name": "Potterton", "model_name": "Performa", "model_qualifier": "24i HE", "winter_efficiency_pct": 85.8, "summer_efficiency_pct": 77.2, "comparative_hot_water_efficiency_pct": 54.3, "output_kw_max": 24.0, "final_year_of_manufacture": 2008, "raw": ["010124", "000005", "0", "2010/Nov/19 09:18", "Baxi Potterton", "Potterton", "Performa", "24i HE", "GC No. 47-393-12", "2004", "2008", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "85.8", "77.2", "", "54.3", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "", "", "0005", "", "", "", "", "", "", "", "", "87.2", "91.5", "", "", "", "", "90.7"]} -{"pcdb_id": 10125, "brand_name": "Potterton", "model_name": "Performa", "model_qualifier": "24 Eco HE", "winter_efficiency_pct": 87.8, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 55.7, "output_kw_max": 24.0, "final_year_of_manufacture": 2012, "raw": ["010125", "000005", "0", "2013/May/07 10:27", "Baxi Potterton", "Potterton", "Performa", "24 Eco HE", "", "2004", "2012", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "87.8", "79.2", "", "55.7", "", "2", "0", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "", "", "0005", "", "", "", "", "", "", "", "", "89.2", "93.7", "", "", "", "", "92.8"]} -{"pcdb_id": 10126, "brand_name": "Potterton", "model_name": "Performa", "model_qualifier": "24 Eco HE", "winter_efficiency_pct": 85.8, "summer_efficiency_pct": 77.2, "comparative_hot_water_efficiency_pct": 54.3, "output_kw_max": 24.0, "final_year_of_manufacture": 2012, "raw": ["010126", "000005", "0", "2013/May/07 10:27", "Baxi Potterton", "Potterton", "Performa", "24 Eco HE", "GC No. 47-393-11", "2004", "2012", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "85.8", "77.2", "", "54.3", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "", "", "0005", "", "", "", "", "", "", "", "", "87.2", "91.5", "", "", "", "", "90.7"]} -{"pcdb_id": 10127, "brand_name": "Mistral", "model_name": "CKUT4 - 1215", "model_qualifier": "Kitchen Utility", "winter_efficiency_pct": 87.2, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 44.0, "final_year_of_manufacture": null, "raw": ["010127", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "CKUT4 - 1215", "Kitchen Utility", "", "2004", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "35.2", "44", "", "", "87.2", "79.4", "", "58.0", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "89.5", "93.2", "", "", "", "", "92.5"]} -{"pcdb_id": 10128, "brand_name": "Mistral", "model_name": "CKUT 3 - 9012", "model_qualifier": "Kitchen Utility", "winter_efficiency_pct": 87.2, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 35.2, "final_year_of_manufacture": null, "raw": ["010128", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "CKUT 3 - 9012", "Kitchen Utility", "", "2004", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "26.4", "35.2", "", "", "87.2", "79.4", "", "58.0", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "89.5", "93.2", "", "", "", "", "92.5"]} -{"pcdb_id": 10129, "brand_name": "Mistral", "model_name": "CK4 - 1215", "model_qualifier": "Kitchen", "winter_efficiency_pct": 87.2, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 44.0, "final_year_of_manufacture": null, "raw": ["010129", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "CK4 - 1215", "Kitchen", "", "2004", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "35.2", "44", "", "", "87.2", "79.4", "", "58.0", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "89.5", "93.2", "", "", "", "", "92.5"]} -{"pcdb_id": 10130, "brand_name": "Mistral", "model_name": "CK 3 - 9012", "model_qualifier": "Kitchen", "winter_efficiency_pct": 87.2, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 35.2, "final_year_of_manufacture": null, "raw": ["010130", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "CK 3 - 9012", "Kitchen", "", "2004", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "26.4", "35.2", "", "", "87.2", "79.4", "", "58.0", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "89.5", "93.2", "", "", "", "", "92.5"]} -{"pcdb_id": 10131, "brand_name": "Mistral", "model_name": "CS3 - 9012", "model_qualifier": "Sealed System", "winter_efficiency_pct": 87.2, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 35.2, "final_year_of_manufacture": null, "raw": ["010131", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "CS3 - 9012", "Sealed System", "", "2004", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "26.4", "35.2", "", "", "87.2", "79.4", "", "58.0", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "89.5", "93.2", "", "", "", "", "92.5"]} -{"pcdb_id": 10132, "brand_name": "Mistral", "model_name": "CS4 - 1215", "model_qualifier": "Sealed System", "winter_efficiency_pct": 87.2, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 44.0, "final_year_of_manufacture": null, "raw": ["010132", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "CS4 - 1215", "Sealed System", "", "2004", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "35.2", "44", "", "", "87.2", "79.4", "", "58.0", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "89.5", "93.2", "", "", "", "", "92.5"]} -{"pcdb_id": 10133, "brand_name": "Mistral", "model_name": "CBH3 - 9012", "model_qualifier": "Boiler House", "winter_efficiency_pct": 87.2, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 35.2, "final_year_of_manufacture": null, "raw": ["010133", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "CBH3 - 9012", "Boiler House", "", "2004", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "26.4", "35.2", "", "", "87.2", "79.4", "", "58.0", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "89.5", "93.2", "", "", "", "", "92.5"]} -{"pcdb_id": 10134, "brand_name": "Mistral", "model_name": "CBH4 - 1215", "model_qualifier": "Boiler House", "winter_efficiency_pct": 87.2, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 44.0, "final_year_of_manufacture": null, "raw": ["010134", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "CBH4 - 1215", "Boiler House", "", "2004", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "35.2", "44", "", "", "87.2", "79.4", "", "58.0", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "89.5", "93.2", "", "", "", "", "92.5"]} -{"pcdb_id": 10135, "brand_name": "Mistral", "model_name": "COD3 - 9012", "model_qualifier": "Outdoor", "winter_efficiency_pct": 87.2, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 35.2, "final_year_of_manufacture": null, "raw": ["010135", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "COD3 - 9012", "Outdoor", "", "2004", "current", "4", "1", "2", "1", "0", "", "", "2", "3", "1", "26.4", "35.2", "", "", "87.2", "79.4", "", "58.0", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "89.5", "93.2", "", "", "", "", "92.5"]} -{"pcdb_id": 10136, "brand_name": "Mistral", "model_name": "COD4 - 1215", "model_qualifier": "Outdoor", "winter_efficiency_pct": 87.2, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 44.0, "final_year_of_manufacture": null, "raw": ["010136", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "COD4 - 1215", "Outdoor", "", "2004", "current", "4", "1", "2", "1", "0", "", "", "2", "3", "1", "35.2", "44", "", "", "87.2", "79.4", "", "58.0", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "89.5", "93.2", "", "", "", "", "92.5"]} -{"pcdb_id": 10137, "brand_name": "Mistral", "model_name": "COD3 - SS - 9012", "model_qualifier": "Outdoor Sealed System", "winter_efficiency_pct": 87.2, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 35.2, "final_year_of_manufacture": null, "raw": ["010137", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "COD3 - SS - 9012", "Outdoor Sealed System", "", "2004", "current", "4", "1", "2", "1", "0", "", "", "2", "3", "1", "26.4", "35.2", "", "", "87.2", "79.4", "", "58.0", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "89.5", "93.2", "", "", "", "", "92.5"]} -{"pcdb_id": 10138, "brand_name": "Mistral", "model_name": "COD4 - SS - 1215", "model_qualifier": "Outdoor Sealed System", "winter_efficiency_pct": 87.2, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 44.0, "final_year_of_manufacture": null, "raw": ["010138", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "COD4 - SS - 1215", "Outdoor Sealed System", "", "2004", "current", "4", "1", "2", "1", "0", "", "", "2", "3", "1", "35.2", "44", "", "", "87.2", "79.4", "", "58.0", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "89.5", "93.2", "", "", "", "", "92.5"]} -{"pcdb_id": 10139, "brand_name": "Mistral", "model_name": "CC3 - 9012", "model_qualifier": "Combi", "winter_efficiency_pct": 87.2, "summer_efficiency_pct": 81.1, "comparative_hot_water_efficiency_pct": 48.5, "output_kw_max": 35.2, "final_year_of_manufacture": null, "raw": ["010139", "000056", "0", "2024/Jan/31 10:17", "Mistral Boilers", "Mistral", "CC3 - 9012", "Combi", "", "2004", "current", "4", "1", "1", "2", "0", "", "", "2", "3", "1", "26.4", "35.2", "", "", "87.2", "81.1", "", "48.5", "", "2", "", "", "203", "1", "1", "", "", "2", "", "0", "62", "0", "25", "3", "75", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "89.5", "93.3", "", "", "", "", "92.6"]} -{"pcdb_id": 10140, "brand_name": "Mistral", "model_name": "CC4 - 1215", "model_qualifier": "Combi", "winter_efficiency_pct": 87.2, "summer_efficiency_pct": 81.1, "comparative_hot_water_efficiency_pct": 48.5, "output_kw_max": 44.0, "final_year_of_manufacture": null, "raw": ["010140", "000056", "0", "2024/Jan/31 10:17", "Mistral Boilers", "Mistral", "CC4 - 1215", "Combi", "", "2004", "current", "4", "1", "1", "2", "0", "", "", "2", "3", "1", "35.2", "44", "", "", "87.2", "81.1", "", "48.5", "", "2", "", "", "203", "1", "1", "", "", "2", "", "0", "62", "0", "25", "3", "75", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "89.5", "93.3", "", "", "", "", "92.6"]} -{"pcdb_id": 10141, "brand_name": "Mistral", "model_name": "COD3 - C - 9012", "model_qualifier": "Outdoor Combi", "winter_efficiency_pct": 87.2, "summer_efficiency_pct": 81.1, "comparative_hot_water_efficiency_pct": 48.5, "output_kw_max": 35.2, "final_year_of_manufacture": null, "raw": ["010141", "000056", "0", "2024/Jan/31 10:17", "Mistral Boilers", "Mistral", "COD3 - C - 9012", "Outdoor Combi", "", "2004", "current", "4", "1", "2", "2", "0", "", "", "2", "3", "1", "26.4", "35.2", "", "", "87.2", "81.1", "", "48.5", "", "2", "", "", "203", "1", "1", "", "", "2", "", "0", "62", "0", "25", "3", "75", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "89.5", "93.3", "", "", "", "", "92.6"]} -{"pcdb_id": 10142, "brand_name": "Mistral", "model_name": "COD4 - C - 1215", "model_qualifier": "Outdoor Combi", "winter_efficiency_pct": 87.2, "summer_efficiency_pct": 81.1, "comparative_hot_water_efficiency_pct": 48.5, "output_kw_max": 44.0, "final_year_of_manufacture": null, "raw": ["010142", "000056", "0", "2024/Jan/31 10:17", "Mistral Boilers", "Mistral", "COD4 - C - 1215", "Outdoor Combi", "", "2004", "current", "4", "1", "2", "2", "0", "", "", "2", "3", "1", "35.2", "44", "", "", "87.2", "81.1", "", "48.5", "", "2", "", "", "203", "1", "1", "", "", "2", "", "0", "62", "0", "25", "3", "75", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "89.5", "93.3", "", "", "", "", "92.6"]} -{"pcdb_id": 10143, "brand_name": "Mistral", "model_name": "OD-C2-7090", "model_qualifier": "Outdoor Combi", "winter_efficiency_pct": 81.5, "summer_efficiency_pct": 73.4, "comparative_hot_water_efficiency_pct": 45.0, "output_kw_max": 26.4, "final_year_of_manufacture": 2006, "raw": ["010143", "000056", "0", "2024/Jan/31 10:17", "Mistral Boilers", "Mistral", "OD-C2-7090", "Outdoor Combi", "", "2004", "2006", "4", "1", "2", "2", "0", "", "", "1", "3", "1", "20.5", "26.4", "", "", "81.5", "73.4", "", "45.0", "", "2", "", "", "203", "1", "1", "", "", "2", "", "0", "37", "0", "25", "3", "75", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.9", "85.0", "", "", "", "", "84.4"]} -{"pcdb_id": 10144, "brand_name": "Mistral", "model_name": "OD-C1-5070", "model_qualifier": "Outdoor Combi", "winter_efficiency_pct": 81.5, "summer_efficiency_pct": 73.4, "comparative_hot_water_efficiency_pct": 45.0, "output_kw_max": 20.5, "final_year_of_manufacture": 2006, "raw": ["010144", "000056", "0", "2024/Jan/31 10:17", "Mistral Boilers", "Mistral", "OD-C1-5070", "Outdoor Combi", "", "2004", "2006", "4", "1", "2", "2", "0", "", "", "1", "3", "1", "14.6", "20.5", "", "", "81.5", "73.4", "", "45.0", "", "2", "", "", "203", "1", "1", "", "", "2", "", "0", "37", "0", "25", "3", "75", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.9", "85.0", "", "", "", "", "84.4"]} -{"pcdb_id": 10145, "brand_name": "Mistral", "model_name": "C2-7090", "model_qualifier": "Combi", "winter_efficiency_pct": 81.5, "summer_efficiency_pct": 73.4, "comparative_hot_water_efficiency_pct": 45.0, "output_kw_max": 26.4, "final_year_of_manufacture": 2006, "raw": ["010145", "000056", "0", "2024/Jan/31 10:17", "Mistral Boilers", "Mistral", "C2-7090", "Combi", "", "2004", "2006", "4", "1", "1", "2", "0", "", "", "1", "3", "1", "20.5", "26.4", "", "", "81.5", "73.4", "", "45.0", "", "2", "", "", "203", "1", "1", "", "", "2", "", "0", "37", "0", "25", "3", "75", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.9", "85.0", "", "", "", "", "84.4"]} -{"pcdb_id": 10147, "brand_name": "Mistral", "model_name": "C1-5070", "model_qualifier": "Combi", "winter_efficiency_pct": 81.5, "summer_efficiency_pct": 73.4, "comparative_hot_water_efficiency_pct": 45.0, "output_kw_max": 20.5, "final_year_of_manufacture": 2006, "raw": ["010147", "000056", "0", "2024/Jan/31 10:17", "Mistral Boilers", "Mistral", "C1-5070", "Combi", "", "2004", "2006", "4", "1", "1", "2", "0", "", "", "1", "3", "1", "14.6", "20.5", "", "", "81.5", "73.4", "", "45.0", "", "2", "", "", "203", "1", "1", "", "", "2", "", "0", "37", "0", "25", "3", "75", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.9", "85.0", "", "", "", "", "84.4"]} -{"pcdb_id": 10148, "brand_name": "Mistral", "model_name": "OD1-SS-5070", "model_qualifier": "Outdoor Sealed System", "winter_efficiency_pct": 83.4, "summer_efficiency_pct": 71.7, "comparative_hot_water_efficiency_pct": 52.4, "output_kw_max": 20.5, "final_year_of_manufacture": 2006, "raw": ["010148", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "OD1-SS-5070", "Outdoor Sealed System", "", "2004", "2006", "4", "1", "2", "1", "0", "", "", "1", "3", "1", "14.6", "20.5", "", "", "83.4", "71.7", "", "52.4", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.9", "85.0", "", "", "", "", "84.4"]} -{"pcdb_id": 10149, "brand_name": "Mistral", "model_name": "OD2-SS-7090", "model_qualifier": "Outdoor Sealed System", "winter_efficiency_pct": 83.4, "summer_efficiency_pct": 71.7, "comparative_hot_water_efficiency_pct": 52.4, "output_kw_max": 26.4, "final_year_of_manufacture": 2006, "raw": ["010149", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "OD2-SS-7090", "Outdoor Sealed System", "", "2004", "2006", "4", "1", "2", "1", "0", "", "", "1", "3", "1", "20.5", "26.4", "", "", "83.4", "71.7", "", "52.4", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.9", "85.0", "", "", "", "", "84.4"]} -{"pcdb_id": 10150, "brand_name": "Mistral", "model_name": "S1-5070", "model_qualifier": "Sealed System", "winter_efficiency_pct": 83.4, "summer_efficiency_pct": 71.7, "comparative_hot_water_efficiency_pct": 52.4, "output_kw_max": 20.5, "final_year_of_manufacture": 2006, "raw": ["010150", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "S1-5070", "Sealed System", "", "2004", "2006", "4", "1", "1", "1", "0", "", "", "1", "3", "1", "14.6", "20.5", "", "", "83.4", "71.7", "", "52.4", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.9", "85.0", "", "", "", "", "84.4"]} -{"pcdb_id": 10151, "brand_name": "Mistral", "model_name": "S2-7090", "model_qualifier": "Sealed System", "winter_efficiency_pct": 83.4, "summer_efficiency_pct": 71.7, "comparative_hot_water_efficiency_pct": 52.4, "output_kw_max": 26.4, "final_year_of_manufacture": 2006, "raw": ["010151", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "S2-7090", "Sealed System", "", "2004", "2006", "4", "1", "1", "1", "0", "", "", "1", "3", "1", "20.5", "26.4", "", "", "83.4", "71.7", "", "52.4", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.9", "85.0", "", "", "", "", "84.4"]} -{"pcdb_id": 10152, "brand_name": "Mistral", "model_name": "OD1-5070", "model_qualifier": "Outdoor", "winter_efficiency_pct": 83.4, "summer_efficiency_pct": 71.7, "comparative_hot_water_efficiency_pct": 52.4, "output_kw_max": 20.5, "final_year_of_manufacture": 2006, "raw": ["010152", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "OD1-5070", "Outdoor", "", "2004", "2006", "4", "1", "2", "1", "0", "", "", "1", "3", "1", "14.6", "20.5", "", "", "83.4", "71.7", "", "52.4", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.9", "85.0", "", "", "", "", "84.4"]} -{"pcdb_id": 10153, "brand_name": "Mistral", "model_name": "OD2-7090", "model_qualifier": "Outdoor", "winter_efficiency_pct": 83.4, "summer_efficiency_pct": 71.7, "comparative_hot_water_efficiency_pct": 52.4, "output_kw_max": 26.4, "final_year_of_manufacture": 2006, "raw": ["010153", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "OD2-7090", "Outdoor", "", "2004", "2006", "4", "1", "2", "1", "0", "", "", "1", "3", "1", "20.5", "26.4", "", "", "83.4", "71.7", "", "52.4", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.9", "85.0", "", "", "", "", "84.4"]} -{"pcdb_id": 10154, "brand_name": "Mistral", "model_name": "K1-5070", "model_qualifier": "Kitchen", "winter_efficiency_pct": 83.4, "summer_efficiency_pct": 71.7, "comparative_hot_water_efficiency_pct": 52.4, "output_kw_max": 20.5, "final_year_of_manufacture": 2006, "raw": ["010154", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "K1-5070", "Kitchen", "", "2004", "2006", "4", "1", "1", "1", "0", "", "", "1", "3", "1", "14.6", "20.5", "", "", "83.4", "71.7", "", "52.4", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.9", "85.0", "", "", "", "", "84.4"]} -{"pcdb_id": 10155, "brand_name": "Mistral", "model_name": "K2-7090", "model_qualifier": "Kitchen", "winter_efficiency_pct": 83.4, "summer_efficiency_pct": 71.7, "comparative_hot_water_efficiency_pct": 52.4, "output_kw_max": 26.4, "final_year_of_manufacture": 2006, "raw": ["010155", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "K2-7090", "Kitchen", "", "2004", "2006", "4", "1", "1", "1", "0", "", "", "1", "3", "1", "20.5", "26.4", "", "", "83.4", "71.7", "", "52.4", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.9", "85.0", "", "", "", "", "84.4"]} -{"pcdb_id": 10156, "brand_name": "Mistral", "model_name": "BH2-7090", "model_qualifier": "Boiler House", "winter_efficiency_pct": 83.4, "summer_efficiency_pct": 71.7, "comparative_hot_water_efficiency_pct": 52.4, "output_kw_max": 26.4, "final_year_of_manufacture": 2006, "raw": ["010156", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "BH2-7090", "Boiler House", "", "2004", "2006", "4", "1", "1", "1", "0", "", "", "1", "3", "1", "20.5", "26.4", "", "", "83.4", "71.7", "", "52.4", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.9", "85.0", "", "", "", "", "84.4"]} -{"pcdb_id": 10157, "brand_name": "Mistral", "model_name": "BH1-5070", "model_qualifier": "Boiler House", "winter_efficiency_pct": 83.4, "summer_efficiency_pct": 71.7, "comparative_hot_water_efficiency_pct": 52.4, "output_kw_max": 20.5, "final_year_of_manufacture": 2006, "raw": ["010157", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "BH1-5070", "Boiler House", "", "2004", "2006", "4", "1", "1", "1", "0", "", "", "1", "3", "1", "14.6", "20.5", "", "", "83.4", "71.7", "", "52.4", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.9", "85.0", "", "", "", "", "84.4"]} -{"pcdb_id": 10158, "brand_name": "Mistral", "model_name": "KUT1 5070", "model_qualifier": "Kitchen Utility", "winter_efficiency_pct": 83.4, "summer_efficiency_pct": 71.7, "comparative_hot_water_efficiency_pct": 52.4, "output_kw_max": 20.5, "final_year_of_manufacture": 2006, "raw": ["010158", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "KUT1 5070", "Kitchen Utility", "", "2004", "2006", "4", "1", "1", "1", "0", "", "", "1", "3", "1", "14.6", "20.5", "", "", "83.4", "71.7", "", "52.4", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.9", "85.0", "", "", "", "", "84.4"]} -{"pcdb_id": 10159, "brand_name": "Mistral", "model_name": "KUT2-7090", "model_qualifier": "Kitchen Utility", "winter_efficiency_pct": 83.4, "summer_efficiency_pct": 71.7, "comparative_hot_water_efficiency_pct": 52.4, "output_kw_max": 26.4, "final_year_of_manufacture": 2006, "raw": ["010159", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "KUT2-7090", "Kitchen Utility", "", "2004", "2006", "4", "1", "1", "1", "0", "", "", "1", "3", "1", "20.5", "26.4", "", "", "83.4", "71.7", "", "52.4", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.9", "85.0", "", "", "", "", "84.4"]} -{"pcdb_id": 10160, "brand_name": "Vokera", "model_name": "Syntesi", "model_qualifier": "29e", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 56.0, "output_kw_max": 28.77, "final_year_of_manufacture": 2010, "raw": ["010160", "000011", "0", "2010/Oct/21 11:09", "Vokera", "Vokera", "Syntesi", "29e", "4709448", "2004", "2010", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28.77", "28.77", "", "", "88.3", "79.7", "", "56.0", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.4", "96.9", "", "", "", "", "95.4"]} -{"pcdb_id": 10161, "brand_name": "Vokera", "model_name": "Synergy", "model_qualifier": "29e", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 28.77, "final_year_of_manufacture": 2010, "raw": ["010161", "000011", "0", "2012/Mar/27 10:12", "Vokera", "Vokera", "Synergy", "29e", "4109427", "2004", "2010", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "28.77", "28.77", "", "", "88.3", "79.3", "", "57.9", "", "2", "", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.4", "96.9", "", "", "", "", "95.4"]} -{"pcdb_id": 10162, "brand_name": "Potterton", "model_name": "Suprima", "model_qualifier": "30 HE", "winter_efficiency_pct": 84.0, "summer_efficiency_pct": 76.4, "comparative_hot_water_efficiency_pct": 55.8, "output_kw_max": 8.82, "final_year_of_manufacture": 2011, "raw": ["010162", "000005", "0", "2013/May/07 10:28", "Baxi Potterton", "Potterton", "Suprima", "30 HE", "GC No. 41-075-35", "2004", "2011", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "8.82", "8.82", "", "", "84.0", "76.4", "", "55.8", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "86.3", "90.9", "", "", "", "", "90.0"]} -{"pcdb_id": 10163, "brand_name": "Potterton", "model_name": "Suprima", "model_qualifier": "40 HE", "winter_efficiency_pct": 84.2, "summer_efficiency_pct": 76.6, "comparative_hot_water_efficiency_pct": 55.9, "output_kw_max": 11.78, "final_year_of_manufacture": 2011, "raw": ["010163", "000005", "0", "2013/May/07 10:28", "Baxi Potterton", "Potterton", "Suprima", "40 HE", "GC No. 41-075-36", "2004", "2011", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "11.78", "11.78", "", "", "84.2", "76.6", "", "55.9", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "86.5", "91.3", "", "", "", "", "90.4"]} -{"pcdb_id": 10164, "brand_name": "Potterton", "model_name": "Suprima", "model_qualifier": "50 HE", "winter_efficiency_pct": 84.0, "summer_efficiency_pct": 76.4, "comparative_hot_water_efficiency_pct": 55.8, "output_kw_max": 14.76, "final_year_of_manufacture": 2011, "raw": ["010164", "000005", "0", "2013/May/07 10:28", "Baxi Potterton", "Potterton", "Suprima", "50 HE", "GC No. 41-075-37", "2004", "2011", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "14.76", "14.76", "", "", "84.0", "76.4", "", "55.8", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "86.7", "90.7", "", "", "", "", "90.0"]} -{"pcdb_id": 10165, "brand_name": "Potterton", "model_name": "Suprima", "model_qualifier": "60 HE", "winter_efficiency_pct": 84.0, "summer_efficiency_pct": 76.4, "comparative_hot_water_efficiency_pct": 55.8, "output_kw_max": 17.72, "final_year_of_manufacture": 2011, "raw": ["010165", "000005", "0", "2013/May/07 10:28", "Baxi Potterton", "Potterton", "Suprima", "60 HE", "GC No. 41-075-38", "2004", "2011", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "17.72", "17.72", "", "", "84.0", "76.4", "", "55.8", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "86.8", "90.6", "", "", "", "", "89.9"]} -{"pcdb_id": 10166, "brand_name": "Potterton", "model_name": "Suprima", "model_qualifier": "70 HE", "winter_efficiency_pct": 84.0, "summer_efficiency_pct": 76.4, "comparative_hot_water_efficiency_pct": 55.8, "output_kw_max": 20.68, "final_year_of_manufacture": 2011, "raw": ["010166", "000005", "0", "2013/May/07 10:28", "Baxi Potterton", "Potterton", "Suprima", "70 HE", "GC No. 41-075-39", "2004", "2011", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "20.68", "20.68", "", "", "84.0", "76.4", "", "55.8", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "86.8", "90.7", "", "", "", "", "90.0"]} -{"pcdb_id": 10167, "brand_name": "Potterton", "model_name": "Suprima", "model_qualifier": "80 HE", "winter_efficiency_pct": 84.0, "summer_efficiency_pct": 76.4, "comparative_hot_water_efficiency_pct": 55.8, "output_kw_max": 23.63, "final_year_of_manufacture": 2011, "raw": ["010167", "000005", "0", "2013/May/07 10:28", "Baxi Potterton", "Potterton", "Suprima", "80 HE", "GC No. 41-075-40", "2004", "2011", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "23.63", "23.63", "", "", "84.0", "76.4", "", "55.8", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "86.8", "90.6", "", "", "", "", "89.9"]} -{"pcdb_id": 10168, "brand_name": "Grant", "model_name": "Vortex", "model_qualifier": "Outdoor Module 36-46", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 46.0, "final_year_of_manufacture": null, "raw": ["010168", "000048", "0", "2012/Mar/27 10:12", "Grant Engineering (UK)", "Grant", "Vortex", "Outdoor Module 36-46", "", "2004", "current", "4", "1", "2", "1", "0", "", "", "2", "1", "2", "36", "46", "", "", "87.9", "80.1", "", "58.5", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.8", "94.4", "", "", "", "", "93.8"]} -{"pcdb_id": 10169, "brand_name": "Grant", "model_name": "Vortex", "model_qualifier": "Outdoor Module 26-36", "winter_efficiency_pct": 90.5, "summer_efficiency_pct": 82.7, "comparative_hot_water_efficiency_pct": 60.4, "output_kw_max": 36.0, "final_year_of_manufacture": null, "raw": ["010169", "000048", "0", "2012/Mar/27 10:12", "Grant Engineering (UK)", "Grant", "Vortex", "Outdoor Module 26-36", "", "2004", "current", "4", "1", "2", "1", "0", "", "", "2", "1", "2", "26", "36", "", "", "90.5", "82.7", "", "60.4", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "95.1", "99.3", "", "", "", "", "98.5"]} -{"pcdb_id": 10170, "brand_name": "Grant", "model_name": "Vortex", "model_qualifier": "Outdoor Module 15-26", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 81.3, "comparative_hot_water_efficiency_pct": 59.4, "output_kw_max": 26.0, "final_year_of_manufacture": null, "raw": ["010170", "000048", "0", "2012/Mar/27 10:12", "Grant Engineering (UK)", "Grant", "Vortex", "Outdoor Module 15-26", "", "2004", "current", "4", "1", "2", "1", "0", "", "", "2", "1", "2", "15", "26", "", "", "89.1", "81.3", "", "59.4", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "93.6", "96.4", "", "", "", "", "95.9"]} -{"pcdb_id": 10171, "brand_name": "Grant", "model_name": "Vortex", "model_qualifier": "Utility 36-46", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 46.0, "final_year_of_manufacture": null, "raw": ["010171", "000048", "0", "2012/Mar/27 10:12", "Grant Engineering (UK)", "Grant", "Vortex", "Utility 36-46", "", "2004", "current", "4", "1", "1", "1", "0", "", "", "2", "2", "2", "36", "46", "", "", "87.9", "80.1", "", "58.5", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.8", "94.4", "", "", "", "", "93.8"]} -{"pcdb_id": 10172, "brand_name": "Grant", "model_name": "Vortex", "model_qualifier": "Utility System 36-46S", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 46.0, "final_year_of_manufacture": null, "raw": ["010172", "000048", "0", "2012/Mar/27 10:12", "Grant Engineering (UK)", "Grant", "Vortex", "Utility System 36-46S", "", "2004", "current", "4", "1", "1", "1", "0", "", "", "2", "2", "2", "36", "46", "", "", "87.9", "80.1", "", "58.5", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.8", "94.4", "", "", "", "", "93.8"]} -{"pcdb_id": 10173, "brand_name": "Trianco", "model_name": "Contractor 100/125", "model_qualifier": "", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 36.6, "final_year_of_manufacture": null, "raw": ["010173", "000062", "0", "2012/Mar/27 10:12", "Trianco", "Trianco", "Contractor 100/125", "", "2301", "2004", "current", "4", "1", "1", "1", "0", "", "", "1", "3", "1", "29.3", "36.6", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "148", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.4", "90.5", "", "", "", "", "89.7"]} -{"pcdb_id": 10174, "brand_name": "Trianco", "model_name": "Contractor 50/90", "model_qualifier": "", "winter_efficiency_pct": 86.6, "summer_efficiency_pct": 74.9, "comparative_hot_water_efficiency_pct": 54.7, "output_kw_max": 26.4, "final_year_of_manufacture": null, "raw": ["010174", "000062", "0", "2012/Mar/27 10:12", "Trianco", "Trianco", "Contractor 50/90", "", "2300", "2004", "current", "4", "1", "1", "1", "0", "", "", "1", "3", "1", "14.7", "26.4", "", "", "86.6", "74.9", "", "54.7", "", "2", "", "", "201", "1", "1", "148", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.2", "87.0", "", "", "", "", "86.8"]} -{"pcdb_id": 10175, "brand_name": "HRM Boilers", "model_name": "Wallstar System", "model_qualifier": "12/15 System 11", "winter_efficiency_pct": 86.4, "summer_efficiency_pct": 74.7, "comparative_hot_water_efficiency_pct": 54.6, "output_kw_max": 15.0, "final_year_of_manufacture": null, "raw": ["010175", "000098", "0", "2012/Mar/27 10:12", "HRM Boilers", "HRM Boilers", "Wallstar System", "12/15 System 11", "", "2004", "current", "4", "2", "1", "1", "0", "", "", "1", "2", "2", "12", "15", "", "", "86.4", "74.7", "", "54.6", "", "2", "", "", "201", "1", "1", "240", "100", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.6", "86.6", "", "", "", "", "86.6"]} -{"pcdb_id": 10178, "brand_name": "Glow-worm", "model_name": "30sxi", "model_qualifier": "", "winter_efficiency_pct": 90.0, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 59.2, "output_kw_max": 28.17, "final_year_of_manufacture": null, "raw": ["010178", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "30sxi", "", "GC 41-047-62", "2002", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "28.17", "28.17", "", "", "90.0", "81.0", "", "59.2", "", "2", "0", "", "102", "1", "2", "180", "15", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.8", "99.0", "", "", "", "", "97.3"]} -{"pcdb_id": 10179, "brand_name": "Ariston", "model_name": "ACO 27 MFFI", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 55.9, "output_kw_max": 22.5, "final_year_of_manufacture": 2007, "raw": ["010179", "000080", "0", "2008/Jun/26 09:07", "Merloni TermoSanitari SpA", "Ariston", "ACO 27 MFFI", "", "GC No 47-116-34", "2004", "2007", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "22.5", "22.5", "", "", "88.1", "79.5", "", "55.9", "", "2", "", "", "104", "1", "2", "118", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.6", "96.9", "", "", "", "", "95.3"]} -{"pcdb_id": 10180, "brand_name": "DD Heating", "model_name": "Heatline", "model_qualifier": "Solaris 24PC", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 55.8, "output_kw_max": 24.42, "final_year_of_manufacture": 2009, "raw": ["010180", "000215", "0", "2011/Aug/31 10:34", "Turk Demir Dokum Fab AS", "DD Heating", "Heatline", "Solaris 24PC", "", "2004", "2009", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.42", "24.42", "", "", "88.0", "79.4", "", "55.8", "", "2", "", "", "104", "1", "2", "140", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "96.8", "", "", "", "", "95.1"]} -{"pcdb_id": 10181, "brand_name": "DD Heating", "model_name": "Heatline", "model_qualifier": "C24", "winter_efficiency_pct": 84.9, "summer_efficiency_pct": 76.3, "comparative_hot_water_efficiency_pct": 53.6, "output_kw_max": 24.82, "final_year_of_manufacture": 2007, "raw": ["010181", "000215", "0", "2011/Aug/31 10:43", "Turk Demir Dokum Fab AS", "DD Heating", "Heatline", "C24", "", "2004", "2007", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.82", "24.82", "", "", "84.9", "76.3", "", "53.6", "", "2", "", "", "104", "1", "2", "196", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.0", "89.3", "", "", "", "", "88.9"]} -{"pcdb_id": 10183, "brand_name": "Mistral", "model_name": "OD4-C-1215", "model_qualifier": "Outdoor Mega Combi", "winter_efficiency_pct": 83.0, "summer_efficiency_pct": 74.9, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 44.0, "final_year_of_manufacture": 2006, "raw": ["010183", "000056", "0", "2024/Jan/31 10:17", "Mistral Boilers", "Mistral", "OD4-C-1215", "Outdoor Mega Combi", "", "2004", "2006", "4", "1", "2", "2", "0", "", "", "1", "3", "1", "35.2", "44", "", "", "83.0", "74.9", "", "40.8", "", "2", "", "", "203", "1", "1", "", "", "2", "", "0", "70", "0", "20", "3", "80", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "84.8", "85.0", "", "", "", "", "85.0"]} -{"pcdb_id": 10184, "brand_name": "Mistral", "model_name": "OD3-C-9012", "model_qualifier": "Outdoor Mega Combi", "winter_efficiency_pct": 83.0, "summer_efficiency_pct": 74.9, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 35.2, "final_year_of_manufacture": 2006, "raw": ["010184", "000056", "0", "2024/Jan/31 10:17", "Mistral Boilers", "Mistral", "OD3-C-9012", "Outdoor Mega Combi", "", "2004", "2006", "4", "1", "2", "2", "0", "", "", "1", "3", "1", "26.4", "35.2", "", "", "83.0", "74.9", "", "40.8", "", "2", "", "", "203", "1", "1", "", "", "2", "", "0", "70", "0", "20", "3", "80", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "84.8", "85.0", "", "", "", "", "85.0"]} -{"pcdb_id": 10185, "brand_name": "Mistral", "model_name": "C4-1215", "model_qualifier": "Mega Combi", "winter_efficiency_pct": 83.0, "summer_efficiency_pct": 74.9, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 44.0, "final_year_of_manufacture": 2006, "raw": ["010185", "000056", "0", "2024/Jan/31 10:17", "Mistral Boilers", "Mistral", "C4-1215", "Mega Combi", "", "2004", "2006", "4", "1", "1", "2", "0", "", "", "1", "3", "1", "35.2", "44", "", "", "83.0", "74.9", "", "40.8", "", "2", "", "", "203", "1", "1", "", "", "2", "", "0", "70", "0", "20", "3", "90", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "84.8", "85.0", "", "", "", "", "85.0"]} -{"pcdb_id": 10187, "brand_name": "Mistral", "model_name": "C3-9012", "model_qualifier": "Mega Combi", "winter_efficiency_pct": 83.0, "summer_efficiency_pct": 74.9, "comparative_hot_water_efficiency_pct": 38.6, "output_kw_max": 35.2, "final_year_of_manufacture": 2006, "raw": ["010187", "000056", "0", "2024/Jan/31 10:17", "Mistral Boilers", "Mistral", "C3-9012", "Mega Combi", "", "2004", "2006", "4", "1", "1", "2", "0", "", "", "1", "3", "1", "26.4", "35.2", "", "", "83.0", "74.9", "", "38.6", "", "2", "", "", "203", "1", "1", "", "", "2", "", "0", "90", "0", "20", "3", "80", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "84.8", "85.0", "", "", "", "", "85.0"]} -{"pcdb_id": 10188, "brand_name": "Mistral", "model_name": "OD4-SS-1215", "model_qualifier": "Outdoor Sealed System", "winter_efficiency_pct": 84.9, "summer_efficiency_pct": 73.2, "comparative_hot_water_efficiency_pct": 53.5, "output_kw_max": 44.0, "final_year_of_manufacture": 2006, "raw": ["010188", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "OD4-SS-1215", "Outdoor Sealed System", "", "2004", "2006", "4", "1", "2", "1", "0", "", "", "1", "3", "1", "35.2", "44", "", "", "84.9", "73.2", "", "53.5", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "84.8", "85.0", "", "", "", "", "85.0"]} -{"pcdb_id": 10189, "brand_name": "Mistral", "model_name": "OD3-SS-9012", "model_qualifier": "Outdoor Sealed System", "winter_efficiency_pct": 84.9, "summer_efficiency_pct": 73.2, "comparative_hot_water_efficiency_pct": 53.5, "output_kw_max": 35.2, "final_year_of_manufacture": 2006, "raw": ["010189", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "OD3-SS-9012", "Outdoor Sealed System", "", "2004", "2006", "4", "1", "2", "1", "0", "", "", "1", "3", "1", "26.4", "35.2", "", "", "84.9", "73.2", "", "53.5", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "84.8", "85.0", "", "", "", "", "85.0"]} -{"pcdb_id": 10190, "brand_name": "Mistral", "model_name": "OD4 - 1215", "model_qualifier": "Outdoor Model", "winter_efficiency_pct": 84.9, "summer_efficiency_pct": 73.2, "comparative_hot_water_efficiency_pct": 53.5, "output_kw_max": 44.0, "final_year_of_manufacture": 2006, "raw": ["010190", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "OD4 - 1215", "Outdoor Model", "", "2004", "2006", "4", "1", "2", "1", "0", "", "", "1", "3", "1", "35.2", "44", "", "", "84.9", "73.2", "", "53.5", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "84.8", "85.0", "", "", "", "", "85.0"]} -{"pcdb_id": 10191, "brand_name": "Mistral", "model_name": "OD3-9012", "model_qualifier": "Outdoor Model", "winter_efficiency_pct": 84.9, "summer_efficiency_pct": 73.2, "comparative_hot_water_efficiency_pct": 53.5, "output_kw_max": 35.2, "final_year_of_manufacture": 2006, "raw": ["010191", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "OD3-9012", "Outdoor Model", "", "2004", "2006", "4", "1", "2", "1", "0", "", "", "1", "3", "1", "26.4", "35.2", "", "", "84.9", "73.2", "", "53.5", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "84.8", "85.0", "", "", "", "", "85.0"]} -{"pcdb_id": 10192, "brand_name": "Mistral", "model_name": "BH4-1215", "model_qualifier": "Boiler House", "winter_efficiency_pct": 84.9, "summer_efficiency_pct": 73.2, "comparative_hot_water_efficiency_pct": 53.5, "output_kw_max": 44.0, "final_year_of_manufacture": 2006, "raw": ["010192", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "BH4-1215", "Boiler House", "", "2004", "2006", "4", "1", "1", "1", "0", "", "", "1", "3", "1", "35.2", "44", "", "", "84.9", "73.2", "", "53.5", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "84.8", "85.0", "", "", "", "", "85.0"]} -{"pcdb_id": 10193, "brand_name": "Mistral", "model_name": "BH3-9012", "model_qualifier": "Boiler House", "winter_efficiency_pct": 84.9, "summer_efficiency_pct": 73.2, "comparative_hot_water_efficiency_pct": 53.5, "output_kw_max": 35.2, "final_year_of_manufacture": 2006, "raw": ["010193", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "BH3-9012", "Boiler House", "", "2004", "2006", "4", "1", "1", "1", "0", "", "", "1", "3", "1", "26.4", "35.2", "", "", "84.9", "73.2", "", "53.5", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "84.8", "85.0", "", "", "", "", "85.0"]} -{"pcdb_id": 10194, "brand_name": "Mistral", "model_name": "S4-1215", "model_qualifier": "Sealed System", "winter_efficiency_pct": 84.9, "summer_efficiency_pct": 73.2, "comparative_hot_water_efficiency_pct": 53.5, "output_kw_max": 44.0, "final_year_of_manufacture": 2006, "raw": ["010194", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "S4-1215", "Sealed System", "", "2004", "2006", "4", "1", "1", "1", "0", "", "", "1", "3", "1", "35.2", "44", "", "", "84.9", "73.2", "", "53.5", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "84.8", "85.0", "", "", "", "", "85.0"]} -{"pcdb_id": 10195, "brand_name": "Mistral", "model_name": "S3-9012", "model_qualifier": "Sealed System", "winter_efficiency_pct": 84.9, "summer_efficiency_pct": 73.2, "comparative_hot_water_efficiency_pct": 53.5, "output_kw_max": 35.2, "final_year_of_manufacture": 2006, "raw": ["010195", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "S3-9012", "Sealed System", "", "2004", "2006", "4", "1", "1", "1", "0", "", "", "1", "3", "1", "26.4", "35.2", "", "", "84.9", "73.2", "", "53.5", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "84.8", "85.0", "", "", "", "", "85.0"]} -{"pcdb_id": 10196, "brand_name": "Mistral", "model_name": "K4-1215", "model_qualifier": "Kitchen", "winter_efficiency_pct": 84.9, "summer_efficiency_pct": 73.2, "comparative_hot_water_efficiency_pct": 53.5, "output_kw_max": 44.0, "final_year_of_manufacture": 2006, "raw": ["010196", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "K4-1215", "Kitchen", "", "2004", "2006", "4", "1", "1", "1", "0", "", "", "1", "3", "1", "35.2", "44", "", "", "84.9", "73.2", "", "53.5", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "84.8", "85.0", "", "", "", "", "85.0"]} -{"pcdb_id": 10197, "brand_name": "Mistral", "model_name": "K3-9012", "model_qualifier": "Kitchen", "winter_efficiency_pct": 84.9, "summer_efficiency_pct": 73.2, "comparative_hot_water_efficiency_pct": 53.5, "output_kw_max": 35.2, "final_year_of_manufacture": 2006, "raw": ["010197", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "K3-9012", "Kitchen", "", "2004", "2006", "4", "1", "1", "1", "0", "", "", "1", "3", "1", "26.4", "35.2", "", "", "84.9", "73.2", "", "53.5", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "84.8", "85.0", "", "", "", "", "85.0"]} -{"pcdb_id": 10198, "brand_name": "Mistral", "model_name": "KUT3-9012", "model_qualifier": "Kitchen Utility", "winter_efficiency_pct": 84.9, "summer_efficiency_pct": 73.2, "comparative_hot_water_efficiency_pct": 53.5, "output_kw_max": 35.2, "final_year_of_manufacture": 2006, "raw": ["010198", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "KUT3-9012", "Kitchen Utility", "", "2004", "2006", "4", "1", "1", "1", "0", "", "", "1", "3", "1", "26.4", "35.2", "", "", "84.9", "73.2", "", "53.5", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "84.8", "85.0", "", "", "", "", "85.0"]} -{"pcdb_id": 10199, "brand_name": "Mistral", "model_name": "KUT4-1215", "model_qualifier": "Kitchen Utility", "winter_efficiency_pct": 84.9, "summer_efficiency_pct": 73.2, "comparative_hot_water_efficiency_pct": 53.5, "output_kw_max": 44.0, "final_year_of_manufacture": 2006, "raw": ["010199", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "KUT4-1215", "Kitchen Utility", "", "2004", "2006", "4", "1", "1", "1", "0", "", "", "1", "3", "1", "35.2", "44", "", "", "84.9", "73.2", "", "53.5", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "84.8", "85.0", "", "", "", "", "85.0"]} -{"pcdb_id": 10200, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "12 Ri", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 12.0, "final_year_of_manufacture": 2015, "raw": ["010200", "000035", "0", "2020/Sep/04 08:08", "Worcester Heat Systems", "Worcester", "Greenstar", "12 Ri", "41-311-63", "2004", "2015", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "12.00", "12.00", "", "", "88.1", "79.1", "", "57.7", "", "2", "", "", "102", "1", "2", "50", "5", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "97.0", "", "", "", "", "95.3"]} -{"pcdb_id": 10201, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "24 Ri", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 24.0, "final_year_of_manufacture": 2015, "raw": ["010201", "000035", "0", "2020/Sep/04 08:08", "Worcester Heat Systems", "Worcester", "Greenstar", "24 Ri", "41-311-65", "2004", "2015", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24", "24", "", "", "88.5", "79.5", "", "58.0", "", "2", "", "", "102", "1", "2", "50", "5", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "97.9", "", "", "", "", "96.1"]} -{"pcdb_id": 10202, "brand_name": "Worcester", "model_name": "Greenstar Highflow", "model_qualifier": "440", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 43.8, "output_kw_max": 29.2, "final_year_of_manufacture": 2008, "raw": ["010202", "000035", "0", "2024/Jan/31 10:17", "Worcester Heat Systems", "Worcester", "Greenstar Highflow", "440", "47 311 82", "2004", "2008", "1", "1", "1", "2", "0", "", "", "2", "2", "2", "29.2", "29.2", "", "", "88.1", "80.8", "", "43.8", "", "2", "", "", "106", "1", "2", "107", "10", "1", "1", "0", "47", "0", "25", "3", "75", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0305", "", "", "", "", "", "", "", "", "88.9", "96.8", "", "", "", "", "95.3"]} -{"pcdb_id": 10203, "brand_name": "Worcester", "model_name": "Greenstar Highflow", "model_qualifier": "440", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 81.8, "comparative_hot_water_efficiency_pct": 44.3, "output_kw_max": 29.2, "final_year_of_manufacture": 2008, "raw": ["010203", "000035", "0", "2024/Jan/31 10:17", "Worcester Heat Systems", "Worcester", "Greenstar Highflow", "440", "47 311 83", "2004", "2008", "2", "1", "1", "2", "0", "", "", "2", "2", "2", "29.2", "29.2", "", "", "89.1", "81.8", "", "44.3", "", "2", "1", "", "106", "1", "2", "107", "10", "1", "1", "0", "47", "0", "25", "3", "75", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0305", "", "", "", "", "", "", "", "", "90.9", "98.9", "", "", "", "", "97.4"]} -{"pcdb_id": 10204, "brand_name": "Vaillant", "model_name": "Ecomax", "model_qualifier": "635E", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 34.9, "final_year_of_manufacture": 2010, "raw": ["010204", "000031", "0", "2012/Mar/27 10:12", "Vaillant", "Vaillant", "Ecomax", "635E", "VU GB 356-C", "2004", "2010", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "34.9", "34.9", "", "", "88.5", "79.5", "", "58.0", "", "2", "", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.0", "97.1", "", "", "", "", "95.8"]} -{"pcdb_id": 10205, "brand_name": "Radiant", "model_name": "Radiant", "model_qualifier": "RBS 24", "winter_efficiency_pct": 79.9, "summer_efficiency_pct": 69.8, "comparative_hot_water_efficiency_pct": 49.1, "output_kw_max": 23.45, "final_year_of_manufacture": null, "raw": ["010205", "000088", "0", "2006/Jan/17 12:31", "Radiant Bruciatori SpA", "Radiant", "Radiant", "RBS 24", "", "2004", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "23.45", "23.45", "", "", "79.9", "69.8", "", "49.1", "", "2", "", "", "104", "1", "2", "170", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.5", "79.7", "", "", "", "", "80.3"]} -{"pcdb_id": 10206, "brand_name": "Halstead", "model_name": "Wickes Combi HE 24", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 56.4, "output_kw_max": 19.3, "final_year_of_manufacture": null, "raw": ["010206", "000019", "0", "2006/Jan/17 12:31", "Halstead Boilers", "Halstead", "Wickes Combi HE 24", "", "4726008", "2004", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "19.3", "19.3", "", "", "88.8", "80.2", "", "56.4", "", "2", "", "", "104", "1", "2", "190", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.1", "98.7", "", "", "", "", "96.7"]} -{"pcdb_id": 10207, "brand_name": "Halstead", "model_name": "Eden CBX 32", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 62.3, "output_kw_max": 25.7, "final_year_of_manufacture": null, "raw": ["010207", "000019", "0", "2006/Jan/17 12:31", "Halstead Boilers", "Halstead", "Eden CBX 32", "", "4726004", "2004", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "25.7", "25.7", "", "", "88.4", "79.8", "", "62.3", "", "2", "", "", "104", "1", "2", "190", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "", "0005", "", "", "", "", "", "", "", "", "89.4", "97.1", "", "", "", "", "95.7"]} -{"pcdb_id": 10208, "brand_name": "Halstead", "model_name": "Eden CBX 24", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 62.6, "output_kw_max": 19.3, "final_year_of_manufacture": null, "raw": ["010208", "000019", "0", "2006/Jan/17 12:31", "Halstead Boilers", "Halstead", "Eden CBX 24", "", "4726005", "2004", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "19.3", "19.3", "", "", "88.8", "80.2", "", "62.6", "", "2", "", "", "104", "1", "2", "190", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "", "0005", "", "", "", "", "", "", "", "", "88.1", "98.7", "", "", "", "", "96.7"]} -{"pcdb_id": 10209, "brand_name": "Halstead", "model_name": "Eden SBX 30", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 32.1, "final_year_of_manufacture": null, "raw": ["010209", "000019", "0", "2012/Mar/27 10:12", "Halstead Boilers", "Halstead", "Eden SBX 30", "", "4126013", "2004", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "32.1", "32.1", "", "", "88.8", "79.8", "", "58.3", "", "2", "", "", "102", "1", "2", "190", "5", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "98.7", "", "", "", "", "96.7"]} -{"pcdb_id": 10210, "brand_name": "Halstead", "model_name": "Eden VBX 18", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 19.3, "final_year_of_manufacture": null, "raw": ["010210", "000019", "0", "2012/Mar/27 10:12", "Halstead Boilers", "Halstead", "Eden VBX 18", "", "4126015", "2004", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "19.3", "19.3", "", "", "88.8", "79.8", "", "58.3", "", "2", "", "", "102", "1", "2", "110", "5", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.1", "98.7", "", "", "", "", "96.7"]} -{"pcdb_id": 10211, "brand_name": "Halstead", "model_name": "Eden VBX 30", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 32.1, "final_year_of_manufacture": null, "raw": ["010211", "000019", "0", "2012/Mar/27 10:12", "Halstead Boilers", "Halstead", "Eden VBX 30", "", "4126014", "2004", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "32.1", "32.1", "", "", "88.8", "79.8", "", "58.3", "", "2", "", "", "102", "1", "2", "110", "5", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "98.7", "", "", "", "", "96.7"]} -{"pcdb_id": 10212, "brand_name": "Halstead", "model_name": "Eden CBX 32", "model_qualifier": "", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 63.0, "output_kw_max": 25.7, "final_year_of_manufacture": null, "raw": ["010212", "000019", "0", "2006/Jan/17 12:31", "Halstead Boilers", "Halstead", "Eden CBX 32", "", "4726006", "2004", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "25.7", "25.7", "", "", "89.4", "80.8", "", "63.0", "", "2", "1", "", "104", "1", "2", "190", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "", "0005", "", "", "", "", "", "", "", "", "91.4", "99.3", "", "", "", "", "97.8"]} -{"pcdb_id": 10213, "brand_name": "Halstead", "model_name": "Eden CBX 24", "model_qualifier": "", "winter_efficiency_pct": 89.8, "summer_efficiency_pct": 81.2, "comparative_hot_water_efficiency_pct": 63.4, "output_kw_max": 19.3, "final_year_of_manufacture": null, "raw": ["010213", "000019", "0", "2006/Jan/17 12:31", "Halstead Boilers", "Halstead", "Eden CBX 24", "", "4726007", "2004", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "19.3", "19.3", "", "", "89.8", "81.2", "", "63.4", "", "2", "1", "", "104", "1", "2", "190", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "", "0005", "", "", "", "", "", "", "", "", "90.1", "100.8", "", "", "", "", "98.8"]} -{"pcdb_id": 10214, "brand_name": "Halstead", "model_name": "Eden SBX 30", "model_qualifier": "", "winter_efficiency_pct": 89.8, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 59.0, "output_kw_max": 32.1, "final_year_of_manufacture": null, "raw": ["010214", "000019", "0", "2012/Mar/27 10:12", "Halstead Boilers", "Halstead", "Eden SBX 30", "", "4126016", "2004", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "32.1", "32.1", "", "", "89.8", "80.8", "", "59.0", "", "2", "1", "", "102", "1", "2", "190", "5", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.3", "100.8", "", "", "", "", "98.8"]} -{"pcdb_id": 10215, "brand_name": "Halstead", "model_name": "Eden VBX 18", "model_qualifier": "", "winter_efficiency_pct": 89.8, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 59.0, "output_kw_max": 19.3, "final_year_of_manufacture": null, "raw": ["010215", "000019", "0", "2012/Mar/27 10:12", "Halstead Boilers", "Halstead", "Eden VBX 18", "", "4126018", "2004", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "19.3", "19.3", "", "", "89.8", "80.8", "", "59.0", "", "2", "1", "", "102", "1", "2", "110", "5", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.1", "100.8", "", "", "", "", "98.8"]} -{"pcdb_id": 10216, "brand_name": "Halstead", "model_name": "Eden VBX 30", "model_qualifier": "", "winter_efficiency_pct": 89.8, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 59.0, "output_kw_max": 32.1, "final_year_of_manufacture": null, "raw": ["010216", "000019", "0", "2012/Mar/27 10:12", "Halstead Boilers", "Halstead", "Eden VBX 30", "", "4126017", "2004", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "32.1", "32.1", "", "", "89.8", "80.8", "", "59.0", "", "2", "1", "", "102", "1", "2", "110", "5", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.3", "100.8", "", "", "", "", "98.8"]} -{"pcdb_id": 10217, "brand_name": "Viessmann", "model_name": "Vitodens 200", "model_qualifier": "WB2A", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 24.7, "final_year_of_manufacture": 2007, "raw": ["010217", "000033", "0", "2012/Dec/06 13:18", "Viessmann", "Viessmann", "Vitodens 200", "WB2A", "", "2004", "2007", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24.7", "24.7", "", "", "88.5", "79.5", "", "58.1", "", "2", "", "", "102", "1", "2", "120", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "98.1", "", "", "", "", "96.2"]} -{"pcdb_id": 10218, "brand_name": "Viessmann", "model_name": "Vitodens 200 Combi", "model_qualifier": "WB2A", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 56.2, "output_kw_max": 24.7, "final_year_of_manufacture": 2007, "raw": ["010218", "000033", "0", "2009/Jan/27 08:30", "Viessmann", "Viessmann", "Vitodens 200 Combi", "WB2A", "", "2004", "2007", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.7", "24.7", "", "", "88.5", "79.9", "", "56.2", "", "2", "", "", "104", "1", "2", "120", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "98.1", "", "", "", "", "96.2"]} -{"pcdb_id": 10219, "brand_name": "Sile SpA", "model_name": "Condensa 32 NN", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 30.0, "final_year_of_manufacture": null, "raw": ["010219", "000221", "0", "2012/Mar/27 10:12", "Sile SpA", "Sile SpA", "Condensa 32 NN", "", "", "2004", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "30.0", "30.0", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "175", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.2", "97.8", "", "", "", "", "96.0"]} -{"pcdb_id": 10221, "brand_name": "Radiant", "model_name": "Radiant", "model_qualifier": "RK 50", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 54.47, "final_year_of_manufacture": null, "raw": ["010221", "000088", "0", "2012/Mar/27 10:12", "Radiant Bruciatori SpA", "Radiant", "Radiant", "RK 50", "", "2004", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "54.47", "54.47", "", "", "88.2", "79.2", "", "57.8", "", "2", "", "", "102", "1", "2", "195", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.1", "97.2", "", "", "", "", "95.5"]} -{"pcdb_id": 10222, "brand_name": "Saunier Duval", "model_name": "Isofast Condens F35e", "model_qualifier": "", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 56.0, "output_kw_max": 28.0, "final_year_of_manufacture": null, "raw": ["010222", "000206", "0", "2009/Mar/31 14:33", "Hepworth Heating", "Saunier Duval", "Isofast Condens F35e", "", "GC 47-920-46", "2004", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28.00", "28.00", "", "", "88.2", "79.6", "", "56.0", "", "2", "", "", "104", "1", "2", "206", "30", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "2", "0", "30", "0005", "", "", "", "", "", "", "", "", "88.1", "97.3", "", "", "", "", "95.6"]} -{"pcdb_id": 10224, "brand_name": "Baxi", "model_name": "Bermuda", "model_qualifier": "50/6 Inset", "winter_efficiency_pct": 79.1, "summer_efficiency_pct": 68.4, "comparative_hot_water_efficiency_pct": 50.0, "output_kw_max": 14.65, "final_year_of_manufacture": 2010, "raw": ["010224", "000005", "0", "2012/Mar/27 10:12", "Baxi Potterton", "Baxi", "Bermuda", "50/6 Inset", "GC No. 44-075-08", "2004", "2010", "1", "4", "1", "1", "0", "", "", "1", "1", "1", "14.65", "14.65", "", "", "79.1", "68.4", "", "50.0", "", "2", "", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.6", "78.6", "", "", "", "", "79.1"]} -{"pcdb_id": 10225, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "12 Ri", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 12.0, "final_year_of_manufacture": 2015, "raw": ["010225", "000035", "0", "2020/Sep/08 09:19", "Worcester Heat Systems", "Worcester", "Greenstar", "12 Ri", "41-311-64", "2004", "2015", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "12.0", "12.0", "", "", "89.1", "80.1", "", "58.5", "", "2", "1", "", "102", "1", "2", "50", "5", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.7", "99.2", "", "", "", "", "97.4"]} -{"pcdb_id": 10226, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "24 Ri", "winter_efficiency_pct": 89.5, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 58.8, "output_kw_max": 24.0, "final_year_of_manufacture": 2015, "raw": ["010226", "000035", "0", "2020/Sep/04 09:25", "Worcester Heat Systems", "Worcester", "Greenstar", "24 Ri", "41-311-66", "2004", "2015", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "24.0", "24.0", "", "", "89.5", "80.5", "", "58.8", "", "2", "1", "", "102", "1", "2", "50", "5", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.0", "100.1", "", "", "", "", "98.2"]} -{"pcdb_id": 10227, "brand_name": "Ariston", "model_name": "ACO 27 RFFI", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 22.5, "final_year_of_manufacture": 2007, "raw": ["010227", "000080", "0", "2012/Mar/27 10:12", "Merloni TermoSanitari SpA", "Ariston", "ACO 27 RFFI", "", "GC No 41-116-09", "2004", "2007", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "22.5", "22.5", "", "", "88.1", "79.1", "", "57.8", "", "2", "", "", "102", "1", "2", "118", "5", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.6", "96.9", "", "", "", "", "95.3"]} -{"pcdb_id": 10228, "brand_name": "Ariston", "model_name": "ACO 32 RFFI", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 28.0, "final_year_of_manufacture": 2007, "raw": ["010228", "000080", "0", "2012/Mar/27 10:12", "Merloni TermoSanitari SpA", "Ariston", "ACO 32 RFFI", "", "GC No 41-116-10", "2004", "2007", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "28", "28", "", "", "88.3", "79.3", "", "57.9", "", "2", "", "", "102", "1", "2", "118", "5", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.7", "97.2", "", "", "", "", "95.6"]} -{"pcdb_id": 10229, "brand_name": "Ariston", "model_name": "ACO 32 MFFI", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 56.0, "output_kw_max": 28.0, "final_year_of_manufacture": 2007, "raw": ["010229", "000080", "0", "2008/Jun/26 09:07", "Merloni TermoSanitari SpA", "Ariston", "ACO 32 MFFI", "", "GC No 47-116-35", "2004", "2007", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28", "28", "", "", "88.3", "79.7", "", "56.0", "", "2", "", "", "104", "1", "2", "118", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.7", "97.2", "", "", "", "", "95.6"]} -{"pcdb_id": 10230, "brand_name": "Baxi", "model_name": "50 HE Plus", "model_qualifier": "", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 15.24, "final_year_of_manufacture": 2006, "raw": ["010230", "000005", "0", "2012/Mar/27 10:12", "Baxi Potterton", "Baxi", "50 HE Plus", "", "GC No. 41-077-41", "2004", "2006", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "15.24", "15.24", "", "", "88.7", "79.7", "", "58.2", "", "2", "", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.3", "97.7", "", "", "", "", "96.3"]} -{"pcdb_id": 10231, "brand_name": "Baxi", "model_name": "80 HE Plus", "model_qualifier": "", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 22.0, "final_year_of_manufacture": 2006, "raw": ["010231", "000005", "0", "2012/Mar/27 10:12", "Baxi Potterton", "Baxi", "80 HE Plus", "", "GC No. 41-077-42", "2004", "2006", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "22.0", "22.0", "", "", "88.9", "79.9", "", "58.4", "", "2", "", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.5", "98.5", "", "", "", "", "96.8"]} -{"pcdb_id": 10232, "brand_name": "Ideal", "model_name": "mini", "model_qualifier": "HE C28", "winter_efficiency_pct": 85.9, "summer_efficiency_pct": 77.3, "comparative_hot_water_efficiency_pct": 54.4, "output_kw_max": 28.3, "final_year_of_manufacture": 2011, "raw": ["010232", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "mini", "HE C28", "47-348-39", "2004", "2011", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28.3", "28.3", "", "", "85.9", "77.3", "", "54.4", "", "2", "", "", "104", "1", "2", "150", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "91.5", "", "", "", "", "90.8"]} -{"pcdb_id": 10233, "brand_name": "Ideal", "model_name": "mini", "model_qualifier": "HE C24", "winter_efficiency_pct": 85.8, "summer_efficiency_pct": 77.2, "comparative_hot_water_efficiency_pct": 54.3, "output_kw_max": 24.6, "final_year_of_manufacture": 2011, "raw": ["010233", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "mini", "HE C24", "47-348-38", "2004", "2011", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.6", "24.6", "", "", "85.8", "77.2", "", "54.3", "", "2", "", "", "104", "1", "2", "140", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.7", "90.9", "", "", "", "", "90.5"]} -{"pcdb_id": 10234, "brand_name": "Ideal", "model_name": "excel", "model_qualifier": "HE C24", "winter_efficiency_pct": 85.3, "summer_efficiency_pct": 76.7, "comparative_hot_water_efficiency_pct": 54.0, "output_kw_max": 23.4, "final_year_of_manufacture": 2009, "raw": ["010234", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "excel", "HE C24", "47-348-35", "2004", "2009", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "23.4", "23.4", "", "", "85.3", "76.7", "", "54.0", "", "2", "", "", "104", "1", "2", "168", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "86.3", "90.7", "", "", "", "", "89.9"]} -{"pcdb_id": 10235, "brand_name": "Ideal", "model_name": "excel", "model_qualifier": "HE C28", "winter_efficiency_pct": 85.3, "summer_efficiency_pct": 76.7, "comparative_hot_water_efficiency_pct": 53.9, "output_kw_max": 28.0, "final_year_of_manufacture": 2009, "raw": ["010235", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "excel", "HE C28", "47-348-36", "2004", "2009", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28.0", "28.0", "", "", "85.3", "76.7", "", "53.9", "", "2", "", "", "104", "1", "2", "180", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "85.5", "91.5", "", "", "", "", "90.3"]} -{"pcdb_id": 10236, "brand_name": "Ideal", "model_name": "excel", "model_qualifier": "HE C32", "winter_efficiency_pct": 85.3, "summer_efficiency_pct": 76.7, "comparative_hot_water_efficiency_pct": 53.9, "output_kw_max": 32.0, "final_year_of_manufacture": 2009, "raw": ["010236", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "excel", "HE C32", "47-348-37", "2004", "2009", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "32.0", "32.0", "", "", "85.3", "76.7", "", "53.9", "", "2", "", "", "104", "1", "2", "184", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "86.0", "90.8", "", "", "", "", "89.9"]} -{"pcdb_id": 10237, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "30 Si", "winter_efficiency_pct": 89.5, "summer_efficiency_pct": 80.9, "comparative_hot_water_efficiency_pct": 63.1, "output_kw_max": 24.0, "final_year_of_manufacture": 2013, "raw": ["010237", "000035", "0", "2020/Sep/04 09:25", "Worcester Heat Systems", "Worcester", "Greenstar", "30 Si", "47-311-89", "2005", "2013", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "89.5", "80.9", "", "63.1", "", "2", "1", "", "104", "1", "2", "140", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "", "0305", "", "", "", "", "", "", "", "", "90.0", "100.1", "", "", "", "", "98.2"]} -{"pcdb_id": 10238, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "25 Si", "winter_efficiency_pct": 89.5, "summer_efficiency_pct": 80.9, "comparative_hot_water_efficiency_pct": 63.1, "output_kw_max": 24.0, "final_year_of_manufacture": 2013, "raw": ["010238", "000035", "0", "2020/Sep/04 09:26", "Worcester Heat Systems", "Worcester", "Greenstar", "25 Si", "47-311-88", "2005", "2013", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "89.5", "80.9", "", "63.1", "", "2", "1", "", "104", "1", "2", "140", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "", "0305", "", "", "", "", "", "", "", "", "90.0", "100.1", "", "", "", "", "98.2"]} -{"pcdb_id": 10239, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "24i junior", "winter_efficiency_pct": 89.5, "summer_efficiency_pct": 90.3, "comparative_hot_water_efficiency_pct": 69.9, "output_kw_max": 24.0, "final_year_of_manufacture": 2015, "raw": ["010239", "000035", "0", "2020/Sep/04 10:30", "Worcester Heat Systems", "Worcester", "Greenstar", "24i junior", "", "2005", "2015", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "89.5", "90.3", "", "69.9", "", "2", "1", "", "104", "1", "2", "140", "3.5", "0", "", "", "0", "0", "", "", "", "", "2", "7.7", "0.133", "0.0008", "1.55951", "13.48", "0.166", "0.0004", "1.54914", "0.0", "1", "1", "", "0305", "", "", "", "", "", "", "", "", "90.0", "100.1", "", "", "", "", "98.2"]} -{"pcdb_id": 10240, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "28i junior", "winter_efficiency_pct": 89.5, "summer_efficiency_pct": 90.3, "comparative_hot_water_efficiency_pct": 70.2, "output_kw_max": 24.0, "final_year_of_manufacture": 2015, "raw": ["010240", "000035", "0", "2020/Sep/04 10:30", "Worcester Heat Systems", "Worcester", "Greenstar", "28i junior", "", "2005", "2015", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "89.5", "90.3", "", "70.2", "", "2", "1", "", "104", "1", "2", "140", "3.5", "0", "", "", "0", "0", "", "", "", "", "2", "7.67", "0.132", "0.0008", "1.53064", "13.58", "0.167", "0.0004", "1.52031", "0.0", "1", "1", "", "0305", "", "", "", "", "", "", "", "", "90.0", "100.1", "", "", "", "", "98.2"]} -{"pcdb_id": 10241, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "30 Si", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 86.7, "comparative_hot_water_efficiency_pct": 64.6, "output_kw_max": 24.0, "final_year_of_manufacture": 2013, "raw": ["010241", "000035", "0", "2020/Sep/04 10:30", "Worcester Heat Systems", "Worcester", "Greenstar", "30 Si", "47-311-85", "2005", "2013", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "88.5", "86.7", "", "64.6", "", "2", "", "", "104", "1", "2", "140", "5", "0", "", "", "0", "0", "", "", "", "", "1", "8.15", "0.27", "0.0106", "1.93522", "", "", "", "", "", "1", "1", "", "0305", "", "", "", "", "", "", "", "", "88.0", "97.9", "", "", "", "", "96.1"]} -{"pcdb_id": 10242, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "25 Si", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 86.7, "comparative_hot_water_efficiency_pct": 65.8, "output_kw_max": 24.0, "final_year_of_manufacture": 2013, "raw": ["010242", "000035", "0", "2020/Sep/04 10:30", "Worcester Heat Systems", "Worcester", "Greenstar", "25 Si", "47-311-84", "2005", "2013", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "88.5", "86.7", "", "65.8", "", "2", "", "", "104", "1", "2", "140", "5", "0", "", "", "0", "0", "", "", "", "", "1", "8.0", "0.26", "0.0104", "1.79206", "", "", "", "", "", "1", "1", "", "0305", "", "", "", "", "", "", "", "", "88.0", "97.9", "", "", "", "", "96.1"]} -{"pcdb_id": 10243, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "24i junior", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 88.2, "comparative_hot_water_efficiency_pct": 67.7, "output_kw_max": 24.0, "final_year_of_manufacture": 2015, "raw": ["010243", "000035", "0", "2020/Sep/04 10:31", "Worcester Heat Systems", "Worcester", "Greenstar", "24i junior", "", "2005", "2015", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "88.5", "88.2", "", "67.7", "", "2", "", "", "104", "1", "2", "140", "3.5", "0", "", "", "0", "0", "", "", "", "", "2", "7.78", "0.128", "0.0024", "1.62713", "13.35", "0.163", "0.0009", "1.60488", "0.00002", "1", "1", "", "0305", "", "", "", "", "", "", "", "", "88.0", "97.9", "", "", "", "", "96.1"]} -{"pcdb_id": 10244, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "28i junior", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 88.2, "comparative_hot_water_efficiency_pct": 67.5, "output_kw_max": 24.0, "final_year_of_manufacture": 2015, "raw": ["010244", "000035", "0", "2020/Sep/04 10:31", "Worcester Heat Systems", "Worcester", "Greenstar", "28i junior", "", "2005", "2015", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "88.5", "88.2", "", "67.5", "", "2", "", "", "104", "1", "2", "140", "3.5", "0", "", "", "0", "0", "", "", "", "", "2", "7.8", "0.134", "0.0018", "1.64959", "13.59", "0.162", "0.0009", "1.62728", "0.00001", "1", "1", "", "0305", "", "", "", "", "", "", "", "", "88.0", "97.9", "", "", "", "", "96.1"]} -{"pcdb_id": 10245, "brand_name": "Vaillant", "model_name": "Ecomax", "model_qualifier": "635 E", "winter_efficiency_pct": 89.5, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 58.8, "output_kw_max": 34.9, "final_year_of_manufacture": 2010, "raw": ["010245", "000031", "0", "2012/Mar/27 10:12", "Vaillant", "Vaillant", "Ecomax", "635 E", "VU GB 356-C", "2004", "2010", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "34.9", "34.9", "", "", "89.5", "80.5", "", "58.8", "", "2", "1", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "92.0", "99.3", "", "", "", "", "97.9"]} -{"pcdb_id": 10246, "brand_name": "DD Heating", "model_name": "Heatline", "model_qualifier": "Solaris 30 PC", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 55.9, "output_kw_max": 29.8, "final_year_of_manufacture": 2009, "raw": ["010246", "000215", "0", "2011/Aug/31 10:34", "Turk Demir Dokum Fab AS", "DD Heating", "Heatline", "Solaris 30 PC", "", "2004", "2009", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "29.8", "29.8", "", "", "88.0", "79.4", "", "55.9", "", "2", "", "", "104", "1", "2", "140", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.1", "96.9", "", "", "", "", "95.2"]} -{"pcdb_id": 10247, "brand_name": "DD Heating", "model_name": "Heatline", "model_qualifier": "Solaris 30PCS", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 29.8, "final_year_of_manufacture": 2009, "raw": ["010247", "000215", "0", "2012/Mar/27 10:12", "Turk Demir Dokum Fab AS", "DD Heating", "Heatline", "Solaris 30PCS", "", "2004", "2009", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "29.8", "29.8", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "140", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.1", "96.9", "", "", "", "", "95.2"]} -{"pcdb_id": 10248, "brand_name": "DD Heating", "model_name": "Heatline", "model_qualifier": "C28", "winter_efficiency_pct": 85.5, "summer_efficiency_pct": 76.9, "comparative_hot_water_efficiency_pct": 54.1, "output_kw_max": 27.47, "final_year_of_manufacture": 2007, "raw": ["010248", "000215", "0", "2011/Aug/31 10:41", "Turk Demir Dokum Fab AS", "DD Heating", "Heatline", "C28", "", "2004", "2007", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "27.47", "27.47", "", "", "85.5", "76.9", "", "54.1", "", "2", "", "", "104", "1", "2", "196", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "86.9", "91.0", "", "", "", "", "90.2"]} -{"pcdb_id": 10249, "brand_name": "DD Heating", "model_name": "Heatline", "model_qualifier": "C28S", "winter_efficiency_pct": 85.5, "summer_efficiency_pct": 76.9, "comparative_hot_water_efficiency_pct": 54.1, "output_kw_max": 27.47, "final_year_of_manufacture": 2007, "raw": ["010249", "000215", "0", "2011/Aug/31 10:40", "Turk Demir Dokum Fab AS", "DD Heating", "Heatline", "C28S", "", "2004", "2007", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "27.47", "27.47", "", "", "85.5", "76.9", "", "54.1", "", "2", "", "", "104", "1", "2", "196", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "86.9", "91.0", "", "", "", "", "90.2"]} -{"pcdb_id": 10251, "brand_name": "Geminox", "model_name": "THI 5-25 C DC", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 23.9, "final_year_of_manufacture": null, "raw": ["010251", "000212", "0", "2012/Mar/27 10:12", "Geminox", "Geminox", "THI 5-25 C DC", "", "", "2004", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "23.9", "23.9", "", "", "88.3", "79.3", "", "58.0", "", "2", "", "", "102", "1", "2", "65", "9.2", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "97.8", "", "", "", "", "95.9"]} -{"pcdb_id": 10252, "brand_name": "Geminox", "model_name": "Astrane 30S FIOUL", "model_qualifier": "", "winter_efficiency_pct": 85.2, "summer_efficiency_pct": 73.5, "comparative_hot_water_efficiency_pct": 53.7, "output_kw_max": 28.2, "final_year_of_manufacture": null, "raw": ["010252", "000212", "0", "2012/Mar/27 10:12", "Geminox", "Geminox", "Astrane 30S FIOUL", "", "", "2003", "current", "4", "1", "1", "1", "0", "", "", "1", "3", "2", "28.2", "28.2", "", "", "85.2", "73.5", "", "53.7", "", "2", "", "", "201", "1", "1", "269", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.5", "84.9", "", "", "", "", "85.0"]} -{"pcdb_id": 10253, "brand_name": "Atmos", "model_name": "InterCombi", "model_qualifier": "HE32", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 62.2, "output_kw_max": 15.7, "final_year_of_manufacture": null, "raw": ["010253", "000141", "0", "2007/Apr/30 11:46", "Intergas Verwarming", "Atmos", "InterCombi", "HE32", "", "2004", "current", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "15.7", "15.7", "", "", "88.3", "79.7", "", "62.2", "", "2", "", "", "104", "1", "2", "40", "2.4", "0", "", "", "1", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "", "0005", "", "", "", "", "", "", "", "", "88.1", "97.5", "", "", "", "", "95.7"]} -{"pcdb_id": 10255, "brand_name": "Viessmann", "model_name": "Vitodens 333", "model_qualifier": "WS3A", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 56.4, "output_kw_max": 23.7, "final_year_of_manufacture": 2007, "raw": ["010255", "000033", "0", "2006/Jan/17 12:31", "Viessmann", "Viessmann", "Vitodens 333", "WS3A", "", "2004", "2007", "1", "1", "1", "2", "0", "", "", "2", "2", "2", "23.7", "23.7", "", "", "88.7", "80.1", "", "56.4", "", "2", "", "", "104", "1", "2", "130", "11", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "98.7", "", "", "", "", "96.6"]} -{"pcdb_id": 10256, "brand_name": "Viessmann", "model_name": "Vitodens 300 Combi", "model_qualifier": "WB3A - 24kW", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 56.4, "output_kw_max": 23.7, "final_year_of_manufacture": 2007, "raw": ["010256", "000033", "0", "2006/Jan/17 12:31", "Viessmann", "Viessmann", "Vitodens 300 Combi", "WB3A - 24kW", "", "2004", "2007", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "23.7", "23.7", "", "", "88.7", "80.1", "", "56.4", "", "2", "", "", "104", "1", "2", "130", "11", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "98.7", "", "", "", "", "96.6"]} -{"pcdb_id": 10257, "brand_name": "Viessmann", "model_name": "Vitodens 300", "model_qualifier": "WB3A - 24kW", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 23.7, "final_year_of_manufacture": 2007, "raw": ["010257", "000033", "0", "2012/Mar/27 10:12", "Viessmann", "Viessmann", "Vitodens 300", "WB3A - 24kW", "", "2004", "2007", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "23.7", "23.7", "", "", "88.7", "79.7", "", "58.2", "", "2", "", "", "102", "1", "2", "130", "11", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "98.7", "", "", "", "", "96.6"]} -{"pcdb_id": 10258, "brand_name": "Viessmann", "model_name": "Vitodens 300", "model_qualifier": "WB3A - 32kW", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 32.0, "final_year_of_manufacture": 2007, "raw": ["010258", "000033", "0", "2012/Mar/27 10:12", "Viessmann", "Viessmann", "Vitodens 300", "WB3A - 32kW", "", "2004", "2007", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "32", "32", "", "", "88.7", "79.7", "", "58.2", "", "2", "", "", "102", "1", "2", "148", "11", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "98.5", "", "", "", "", "96.5"]} -{"pcdb_id": 10259, "brand_name": "Viessmann", "model_name": "Vitodens 300", "model_qualifier": "WB3A - 44kW", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 44.6, "final_year_of_manufacture": 2007, "raw": ["010259", "000033", "0", "2012/Mar/27 10:12", "Viessmann", "Viessmann", "Vitodens 300", "WB3A - 44kW", "", "2004", "2007", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "44.6", "44.6", "", "", "88.5", "79.5", "", "58.1", "", "2", "", "", "102", "1", "2", "72", "11", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "98.0", "", "", "", "", "96.1"]} -{"pcdb_id": 10260, "brand_name": "Viessmann", "model_name": "Vitodens 300", "model_qualifier": "WB3A - 66kW", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 60.1, "final_year_of_manufacture": 2007, "raw": ["010260", "000033", "0", "2012/Mar/27 10:12", "Viessmann", "Viessmann", "Vitodens 300", "WB3A - 66kW", "", "2004", "2007", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "60.1", "60.1", "", "", "88.5", "79.5", "", "58.1", "", "2", "", "", "102", "1", "2", "104", "11", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "98.2", "", "", "", "", "96.2"]} -{"pcdb_id": 10261, "brand_name": "Potterton", "model_name": "Promax", "model_qualifier": "15/2 HE Plus", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 15.24, "final_year_of_manufacture": 2010, "raw": ["010261", "000005", "0", "2012/Mar/27 10:12", "Baxi Potterton", "Potterton", "Promax", "15/2 HE Plus", "GC No. 41-605-52", "2005", "2010", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "15.24", "15.24", "", "", "88.7", "79.7", "", "58.2", "", "2", "", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.3", "97.7", "", "", "", "", "96.3"]} -{"pcdb_id": 10262, "brand_name": "Potterton", "model_name": "Promax", "model_qualifier": "24/2 HE Plus", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 22.0, "final_year_of_manufacture": 2010, "raw": ["010262", "000005", "0", "2012/Mar/27 10:12", "Baxi Potterton", "Potterton", "Promax", "24/2 HE Plus", "GC No. 41-601-17", "2005", "2010", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "22.0", "22.0", "", "", "88.9", "79.9", "", "58.4", "", "2", "", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.5", "98.5", "", "", "", "", "96.8"]} -{"pcdb_id": 10263, "brand_name": "Worcester", "model_name": "Greenstar CDi", "model_qualifier": "25 Cdi", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 56.8, "output_kw_max": 25.0, "final_year_of_manufacture": 2007, "raw": ["010263", "000035", "0", "2020/Sep/04 10:31", "Worcester Heat Systems", "Worcester", "Greenstar CDi", "25 Cdi", "47-311-92", "2005", "2007", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "25", "25", "", "", "89.4", "80.8", "", "56.8", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0305", "", "", "", "", "", "", "", "", "88.5", "100.3", "", "", "", "", "98.0"]} -{"pcdb_id": 10264, "brand_name": "Worcester", "model_name": "Greenstar CDi", "model_qualifier": "25 Cdi", "winter_efficiency_pct": 90.5, "summer_efficiency_pct": 81.9, "comparative_hot_water_efficiency_pct": 57.6, "output_kw_max": 25.0, "final_year_of_manufacture": 2007, "raw": ["010264", "000035", "0", "2020/Sep/04 10:32", "Worcester Heat Systems", "Worcester", "Greenstar CDi", "25 Cdi", "", "2005", "2007", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "25", "25", "", "", "90.5", "81.9", "", "57.6", "", "2", "1", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0305", "", "", "", "", "", "", "", "", "90.4", "102.5", "", "", "", "", "100.2"]} -{"pcdb_id": 10265, "brand_name": "Worcester", "model_name": "Greenstar CDi", "model_qualifier": "30 CDi", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 56.4, "output_kw_max": 30.0, "final_year_of_manufacture": 2007, "raw": ["010265", "000035", "0", "2020/Sep/08 09:20", "Worcester Heat Systems", "Worcester", "Greenstar CDi", "30 CDi", "47-311-93", "2005", "2007", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "30", "30", "", "", "88.8", "80.2", "", "56.4", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0305", "", "", "", "", "", "", "", "", "88.1", "98.8", "", "", "", "", "96.8"]} -{"pcdb_id": 10266, "brand_name": "Worcester", "model_name": "Greenstar CDi", "model_qualifier": "30 Cdi", "winter_efficiency_pct": 89.8, "summer_efficiency_pct": 81.2, "comparative_hot_water_efficiency_pct": 57.1, "output_kw_max": 30.0, "final_year_of_manufacture": 2007, "raw": ["010266", "000035", "0", "2020/Sep/08 09:22", "Worcester Heat Systems", "Worcester", "Greenstar CDi", "30 Cdi", "", "2005", "2007", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "30", "30", "", "", "89.8", "81.2", "", "57.1", "", "2", "1", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0305", "", "", "", "", "", "", "", "", "90.1", "101.0", "", "", "", "", "99.0"]} -{"pcdb_id": 10267, "brand_name": "Worcester", "model_name": "Greenstar CDi", "model_qualifier": "35 CDi", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 56.4, "output_kw_max": 30.0, "final_year_of_manufacture": 2007, "raw": ["010267", "000035", "0", "2020/Sep/08 09:22", "Worcester Heat Systems", "Worcester", "Greenstar CDi", "35 CDi", "47-311-94", "2005", "2007", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "30", "30", "", "", "88.8", "80.2", "", "56.4", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0305", "", "", "", "", "", "", "", "", "88.1", "98.8", "", "", "", "", "96.8"]} -{"pcdb_id": 10268, "brand_name": "Worcester", "model_name": "Greenstar CDi", "model_qualifier": "35 Cdi", "winter_efficiency_pct": 89.8, "summer_efficiency_pct": 81.2, "comparative_hot_water_efficiency_pct": 57.1, "output_kw_max": 30.0, "final_year_of_manufacture": 2007, "raw": ["010268", "000035", "0", "2020/Sep/08 09:22", "Worcester Heat Systems", "Worcester", "Greenstar CDi", "35 Cdi", "", "2005", "2007", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "30", "30", "", "", "89.8", "81.2", "", "57.1", "", "2", "1", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0305", "", "", "", "", "", "", "", "", "90.1", "101.0", "", "", "", "", "99.0"]} -{"pcdb_id": 10269, "brand_name": "Ariston", "model_name": "Microgenus 24 HE MFFI", "model_qualifier": "", "winter_efficiency_pct": 86.0, "summer_efficiency_pct": 77.4, "comparative_hot_water_efficiency_pct": 54.4, "output_kw_max": 23.3, "final_year_of_manufacture": 2008, "raw": ["010269", "000080", "0", "2009/Jul/28 09:49", "Merloni TermoSanitari SpA", "Ariston", "Microgenus 24 HE MFFI", "", "GC No. 47-116-37", "2004", "2008", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "23.3", "23.3", "", "", "86.0", "77.4", "", "54.4", "", "2", "", "", "104", "1", "2", "148", "7", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.5", "91.9", "", "", "", "", "91.1"]} -{"pcdb_id": 10270, "brand_name": "Ariston", "model_name": "Microgenus 28 HE MFFI", "model_qualifier": "", "winter_efficiency_pct": 85.7, "summer_efficiency_pct": 77.1, "comparative_hot_water_efficiency_pct": 54.2, "output_kw_max": 27.0, "final_year_of_manufacture": 2008, "raw": ["010270", "000080", "0", "2009/Jul/28 09:46", "Merloni TermoSanitari SpA", "Ariston", "Microgenus 28 HE MFFI", "", "GC No. 47-116-39", "2004", "2008", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "27.0", "27.0", "", "", "85.7", "77.1", "", "54.2", "", "2", "", "", "104", "1", "2", "148", "7", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "86.8", "91.5", "", "", "", "", "90.6"]} -{"pcdb_id": 10271, "brand_name": "Ariston", "model_name": "Microgenus 32 HE MFFI", "model_qualifier": "", "winter_efficiency_pct": 85.9, "summer_efficiency_pct": 77.3, "comparative_hot_water_efficiency_pct": 54.3, "output_kw_max": 30.5, "final_year_of_manufacture": 2008, "raw": ["010271", "000080", "0", "2009/Jul/28 09:48", "Merloni TermoSanitari SpA", "Ariston", "Microgenus 32 HE MFFI", "", "GC No. 47-116-38", "2004", "2008", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "30.5", "30.5", "", "", "85.9", "77.3", "", "54.3", "", "2", "", "", "104", "1", "2", "148", "7", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.1", "91.7", "", "", "", "", "90.8"]} -{"pcdb_id": 10272, "brand_name": "Radiant", "model_name": "B-condense", "model_qualifier": "RHR 28", "winter_efficiency_pct": 85.2, "summer_efficiency_pct": 76.6, "comparative_hot_water_efficiency_pct": 53.9, "output_kw_max": 27.47, "final_year_of_manufacture": 2007, "raw": ["010272", "000088", "0", "2007/Sep/03 13:03", "Radiant Bruciatori SpA", "Radiant", "B-condense", "RHR 28", "", "2005", "2007", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "27.47", "27.47", "", "", "85.2", "76.6", "", "53.9", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "85.8", "90.8", "", "", "", "", "89.9"]} -{"pcdb_id": 10273, "brand_name": "Radiant", "model_name": "B-condense", "model_qualifier": "RH 28", "winter_efficiency_pct": 85.2, "summer_efficiency_pct": 76.2, "comparative_hot_water_efficiency_pct": 55.7, "output_kw_max": 27.47, "final_year_of_manufacture": 2007, "raw": ["010273", "000088", "0", "2012/Mar/27 10:12", "Radiant Bruciatori SpA", "Radiant", "B-condense", "RH 28", "", "2005", "2007", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "27.47", "27.47", "", "", "85.2", "76.2", "", "55.7", "", "2", "", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "85.8", "90.8", "", "", "", "", "89.9"]} -{"pcdb_id": 10274, "brand_name": "Ferroli", "model_name": "Optimax", "model_qualifier": "25 C LPG", "winter_efficiency_pct": 89.7, "summer_efficiency_pct": 81.1, "comparative_hot_water_efficiency_pct": 57.1, "output_kw_max": 24.7, "final_year_of_manufacture": 2008, "raw": ["010274", "000097", "0", "2009/Apr/28 16:11", "Ferroli SpA", "Ferroli", "Optimax", "25 C LPG", "", "2004", "2008", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24.7", "24.7", "", "", "89.7", "81.1", "", "57.1", "", "2", "1", "", "104", "1", "2", "140", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "", "", "0005", "", "", "", "", "", "", "", "", "90.4", "100.7", "", "", "", "", "98.7"]} -{"pcdb_id": 10275, "brand_name": "Ferroli", "model_name": "Optimax", "model_qualifier": "25 S LPG", "winter_efficiency_pct": 89.7, "summer_efficiency_pct": 80.7, "comparative_hot_water_efficiency_pct": 59.0, "output_kw_max": 25.0, "final_year_of_manufacture": 2008, "raw": ["010275", "000097", "0", "2012/Mar/27 10:12", "Ferroli SpA", "Ferroli", "Optimax", "25 S LPG", "", "2004", "2008", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "25.0", "25.0", "", "", "89.7", "80.7", "", "59.0", "", "2", "1", "", "102", "1", "2", "130", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.4", "100.7", "", "", "", "", "98.7"]} -{"pcdb_id": 10276, "brand_name": "Ferroli", "model_name": "Optimax", "model_qualifier": "25 OV LPG", "winter_efficiency_pct": 89.7, "summer_efficiency_pct": 80.7, "comparative_hot_water_efficiency_pct": 59.0, "output_kw_max": 24.7, "final_year_of_manufacture": 2008, "raw": ["010276", "000097", "0", "2012/Mar/27 10:12", "Ferroli SpA", "Ferroli", "Optimax", "25 OV LPG", "", "2004", "2008", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "24.7", "24.7", "", "", "89.7", "80.7", "", "59.0", "", "2", "1", "", "102", "1", "2", "60", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.4", "100.7", "", "", "", "", "98.7"]} -{"pcdb_id": 10277, "brand_name": "Ferroli", "model_name": "Maxima", "model_qualifier": "35 C LPG", "winter_efficiency_pct": 89.9, "summer_efficiency_pct": 81.3, "comparative_hot_water_efficiency_pct": 57.2, "output_kw_max": 34.1, "final_year_of_manufacture": 2008, "raw": ["010277", "000097", "0", "2009/Apr/28 16:00", "Ferroli SpA", "Ferroli", "Maxima", "35 C LPG", "", "2004", "2008", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "34.1", "34.1", "", "", "89.9", "81.3", "", "57.2", "", "2", "1", "", "104", "1", "2", "150", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "", "", "0005", "", "", "", "", "", "", "", "", "91.6", "100.5", "", "", "", "", "98.8"]} -{"pcdb_id": 10278, "brand_name": "Ferroli", "model_name": "Maxima", "model_qualifier": "35 S LPG", "winter_efficiency_pct": 89.9, "summer_efficiency_pct": 80.9, "comparative_hot_water_efficiency_pct": 59.1, "output_kw_max": 34.6, "final_year_of_manufacture": 2008, "raw": ["010278", "000097", "0", "2012/Mar/27 10:12", "Ferroli SpA", "Ferroli", "Maxima", "35 S LPG", "", "2004", "2008", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "34.6", "34.6", "", "", "89.9", "80.9", "", "59.1", "", "2", "1", "", "102", "1", "2", "150", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "91.6", "100.5", "", "", "", "", "98.8"]} -{"pcdb_id": 10279, "brand_name": "Ferroli", "model_name": "Econcept", "model_qualifier": "50 A LPG", "winter_efficiency_pct": 89.6, "summer_efficiency_pct": 80.6, "comparative_hot_water_efficiency_pct": 58.9, "output_kw_max": 45.2, "final_year_of_manufacture": 2017, "raw": ["010279", "000097", "0", "2017/Aug/21 13:42", "Ferroli SpA", "Ferroli", "Econcept", "50 A LPG", "", "2002", "2017", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "45.2", "45.2", "", "", "89.6", "80.6", "", "58.9", "", "2", "1", "", "102", "1", "2", "190", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.4", "100.4", "", "", "", "", "98.5"]} -{"pcdb_id": 10281, "brand_name": "MHS Boilers", "model_name": "Ultramax WM", "model_qualifier": "65", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 59.2, "final_year_of_manufacture": null, "raw": ["010281", "000024", "0", "2012/Mar/27 10:12", "Rendamax", "MHS Boilers", "Ultramax WM", "65", "", "2004", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "59.2", "59.2", "", "", "88.2", "79.2", "", "57.8", "", "2", "", "", "102", "1", "2", "98", "10", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "97.3", "", "", "", "", "95.5"]} -{"pcdb_id": 10286, "brand_name": "MHS Boilers", "model_name": "Ultramax WM", "model_qualifier": "65", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 59.2, "final_year_of_manufacture": null, "raw": ["010286", "000024", "0", "2012/Mar/27 10:12", "Rendamax", "MHS Boilers", "Ultramax WM", "65", "", "2004", "current", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "59.2", "59.2", "", "", "89.2", "80.2", "", "58.6", "", "2", "1", "", "102", "1", "2", "98", "10", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.8", "99.5", "", "", "", "", "97.6"]} -{"pcdb_id": 10291, "brand_name": "Keston", "model_name": "C", "model_qualifier": "36 Combi", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 80.6, "comparative_hot_water_efficiency_pct": 56.7, "output_kw_max": 28.0, "final_year_of_manufacture": null, "raw": ["010291", "000022", "0", "2006/Jan/17 12:31", "Keston Boilers", "Keston", "C", "36 Combi", "47-930-01", "2005", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28.0", "28.0", "", "", "89.2", "80.6", "", "56.7", "", "2", "", "", "104", "1", "2", "180", "6", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "", "", "0005", "", "", "", "", "", "", "", "", "89.2", "99.3", "", "", "", "", "97.4"]} -{"pcdb_id": 10292, "brand_name": "Keston", "model_name": "C", "model_qualifier": "36P Combi", "winter_efficiency_pct": 90.2, "summer_efficiency_pct": 81.6, "comparative_hot_water_efficiency_pct": 57.4, "output_kw_max": 27.7, "final_year_of_manufacture": null, "raw": ["010292", "000022", "0", "2006/Jan/17 12:31", "Keston Boilers", "Keston", "C", "36P Combi", "47-930-02", "2005", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "27.7", "27.7", "", "", "90.2", "81.6", "", "57.4", "", "2", "1", "", "104", "1", "2", "180", "6", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "", "", "0005", "", "", "", "", "", "", "", "", "91.2", "101.5", "", "", "", "", "99.5"]} -{"pcdb_id": 10293, "brand_name": "Boulter", "model_name": "Buderus", "model_qualifier": "500-24/C", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.4, "comparative_hot_water_efficiency_pct": 56.5, "output_kw_max": 23.0, "final_year_of_manufacture": null, "raw": ["010293", "000041", "0", "2006/Jan/17 12:31", "Boulter Buderus", "Boulter", "Buderus", "500-24/C", "87470242", "2005", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "23.0", "23.0", "", "", "89.0", "80.4", "", "56.5", "", "2", "", "", "104", "1", "2", "40", "6.5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "99.4", "", "", "", "", "97.2"]} -{"pcdb_id": 10294, "brand_name": "Boulter", "model_name": "Buderus", "model_qualifier": "500-24/CP", "winter_efficiency_pct": 90.0, "summer_efficiency_pct": 81.4, "comparative_hot_water_efficiency_pct": 57.3, "output_kw_max": 23.0, "final_year_of_manufacture": null, "raw": ["010294", "000041", "0", "2006/Jan/17 12:31", "Boulter Buderus", "Boulter", "Buderus", "500-24/CP", "87470222", "2005", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "23.0", "23.0", "", "", "90.0", "81.4", "", "57.3", "", "2", "1", "", "104", "1", "2", "40", "6.5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.8", "101.6", "", "", "", "", "99.3"]} -{"pcdb_id": 10295, "brand_name": "Firebird", "model_name": "Kitchen C20", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 58.8, "output_kw_max": 20.0, "final_year_of_manufacture": 2010, "raw": ["010295", "000047", "0", "2012/Mar/27 10:12", "Firebird Boilers", "Firebird", "Kitchen C20", "", "", "2005", "2010", "4", "1", "1", "1", "0", "", "", "2", "2", "1", "15", "20", "", "", "88.3", "80.5", "", "58.8", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.7", "95.2", "", "", "", "", "94.5"]} -{"pcdb_id": 10296, "brand_name": "Firebird", "model_name": "Kitchen C26", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 58.8, "output_kw_max": 26.0, "final_year_of_manufacture": 2010, "raw": ["010296", "000047", "0", "2012/Mar/27 10:12", "Firebird Boilers", "Firebird", "Kitchen C26", "", "", "2005", "2010", "4", "1", "1", "1", "0", "", "", "2", "2", "1", "20", "26", "", "", "88.3", "80.5", "", "58.8", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.5", "95.3", "", "", "", "", "94.6"]} -{"pcdb_id": 10297, "brand_name": "Firebird", "model_name": "Kitchen C35", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 58.7, "output_kw_max": 35.0, "final_year_of_manufacture": 2010, "raw": ["010297", "000047", "0", "2012/Mar/27 10:12", "Firebird Boilers", "Firebird", "Kitchen C35", "", "", "2005", "2010", "4", "1", "1", "1", "0", "", "", "2", "2", "1", "26", "35", "", "", "88.1", "80.3", "", "58.7", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.4", "94.9", "", "", "", "", "94.2"]} -{"pcdb_id": 10298, "brand_name": "Firebird", "model_name": "Combi C20", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 82.2, "comparative_hot_water_efficiency_pct": 45.0, "output_kw_max": 20.0, "final_year_of_manufacture": 2010, "raw": ["010298", "000047", "0", "2024/Jan/31 10:17", "Firebird Boilers", "Firebird", "Combi C20", "", "", "2005", "2010", "4", "1", "1", "2", "0", "", "", "2", "2", "1", "15", "20", "", "", "88.3", "82.2", "", "45.0", "", "2", "", "", "203", "1", "1", "138", "0", "1", "1", "0", "40", "0", "25", "3", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.7", "95.2", "", "", "", "", "94.5"]} -{"pcdb_id": 10299, "brand_name": "Firebird", "model_name": "Combi C26", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 82.2, "comparative_hot_water_efficiency_pct": 45.0, "output_kw_max": 26.0, "final_year_of_manufacture": 2010, "raw": ["010299", "000047", "0", "2024/Jan/31 10:17", "Firebird Boilers", "Firebird", "Combi C26", "", "", "2005", "2010", "4", "1", "1", "2", "0", "", "", "2", "2", "1", "20", "26", "", "", "88.3", "82.2", "", "45.0", "", "2", "", "", "203", "1", "1", "138", "0", "1", "1", "0", "40", "0", "25", "3", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.5", "95.3", "", "", "", "", "94.6"]} -{"pcdb_id": 10300, "brand_name": "Firebird", "model_name": "Combi C35", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 82.0, "comparative_hot_water_efficiency_pct": 44.9, "output_kw_max": 35.0, "final_year_of_manufacture": 2010, "raw": ["010300", "000047", "0", "2024/Jan/31 10:17", "Firebird Boilers", "Firebird", "Combi C35", "", "", "2005", "2010", "4", "1", "1", "2", "0", "", "", "2", "2", "1", "26", "35", "", "", "88.1", "82.0", "", "44.9", "", "2", "", "", "203", "1", "1", "138", "0", "1", "1", "0", "40", "0", "25", "3", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.4", "94.9", "", "", "", "", "94.2"]} -{"pcdb_id": 10301, "brand_name": "Hermann Srl", "model_name": "Eura Condensing", "model_qualifier": "", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 61.9, "output_kw_max": 27.6, "final_year_of_manufacture": null, "raw": ["010301", "000234", "0", "2013/Jun/25 14:34", "Hermann Srl", "Hermann Srl", "Eura Condensing", "", "CHM573U24", "2003", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "27.6", "27.6", "", "", "87.9", "79.3", "", "61.9", "", "2", "", "", "104", "1", "2", "195", "120", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "", "0005", "", "", "", "", "", "", "", "", "89.0", "96.2", "", "", "", "", "94.9"]} -{"pcdb_id": 10302, "brand_name": "Chaffoteaux et Maury", "model_name": "Minima HE 35", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 56.2, "output_kw_max": 32.0, "final_year_of_manufacture": 2007, "raw": ["010302", "000010", "0", "2008/Jun/26 09:09", "Chaffoteaux et Maury", "Chaffoteaux et Maury", "Minima HE 35", "", "GC No. 47-980-35", "2004", "2007", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "32", "32", "", "", "88.5", "79.9", "", "56.2", "", "2", "", "", "104", "1", "2", "150", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "98.1", "", "", "", "", "96.2"]} -{"pcdb_id": 10303, "brand_name": "Chaffoteaux et Maury", "model_name": "Minima HE 30", "model_qualifier": "", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 55.9, "output_kw_max": 29.0, "final_year_of_manufacture": 2007, "raw": ["010303", "000010", "0", "2008/Jun/26 09:09", "Chaffoteaux et Maury", "Chaffoteaux et Maury", "Minima HE 30", "", "GC No. 47-980-34", "2004", "2007", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "29", "29", "", "", "88.2", "79.6", "", "55.9", "", "2", "", "", "104", "1", "2", "150", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.1", "97.1", "", "", "", "", "95.4"]} -{"pcdb_id": 10304, "brand_name": "Chaffoteaux et Maury", "model_name": "Minima HE System 30", "model_qualifier": "", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 29.0, "final_year_of_manufacture": 2007, "raw": ["010304", "000010", "0", "2012/Mar/27 10:12", "Chaffoteaux et Maury", "Chaffoteaux et Maury", "Minima HE System 30", "", "", "2004", "2007", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "29", "29", "", "", "88.2", "79.2", "", "57.8", "", "2", "", "", "102", "1", "2", "150", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.1", "97.1", "", "", "", "", "95.4"]} -{"pcdb_id": 10305, "brand_name": "Chaffoteaux et Maury", "model_name": "Minima HE System 24", "model_qualifier": "", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 24.0, "final_year_of_manufacture": 2007, "raw": ["010305", "000010", "0", "2012/Mar/27 10:12", "Chaffoteaux et Maury", "Chaffoteaux et Maury", "Minima HE System 24", "", "", "2004", "2007", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24", "24", "", "", "88.2", "79.2", "", "57.9", "", "2", "", "", "102", "1", "2", "150", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "97.5", "", "", "", "", "95.7"]} -{"pcdb_id": 10306, "brand_name": "Chaffoteaux et Maury", "model_name": "Minima HE 24", "model_qualifier": "", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 56.0, "output_kw_max": 24.0, "final_year_of_manufacture": 2007, "raw": ["010306", "000010", "0", "2008/Jun/26 09:08", "Chaffoteaux et Maury", "Chaffoteaux et Maury", "Minima HE 24", "", "GC No. 47-980-33", "2004", "2007", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "88.2", "79.6", "", "56.0", "", "2", "", "", "104", "1", "2", "150", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "97.5", "", "", "", "", "95.7"]} -{"pcdb_id": 10307, "brand_name": "Saunier Duval", "model_name": "Xeon 18 HE", "model_qualifier": "", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 78.9, "comparative_hot_water_efficiency_pct": 57.6, "output_kw_max": 18.57, "final_year_of_manufacture": null, "raw": ["010307", "000206", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Saunier Duval", "Xeon 18 HE", "", "GC 41-920-38", "2005", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18.57", "18.57", "", "", "87.9", "78.9", "", "57.6", "", "2", "", "", "102", "1", "2", "60", "15", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.6", "96.3", "", "", "", "", "94.8"]} -{"pcdb_id": 10308, "brand_name": "Saunier Duval", "model_name": "Xeon 30 HE", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 28.17, "final_year_of_manufacture": null, "raw": ["010308", "000206", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Saunier Duval", "Xeon 30 HE", "", "GC 41-920-46", "2005", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "28.17", "28.17", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "60", "15", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.7", "96.4", "", "", "", "", "95.0"]} -{"pcdb_id": 10309, "brand_name": "Saunier Duval", "model_name": "Xeon 30HE LPG", "model_qualifier": "", "winter_efficiency_pct": 90.0, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 59.2, "output_kw_max": 28.17, "final_year_of_manufacture": null, "raw": ["010309", "000206", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Saunier Duval", "Xeon 30HE LPG", "", "", "2005", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "28.17", "28.17", "", "", "90.0", "81.0", "", "59.2", "", "2", "0", "", "102", "1", "2", "60", "15", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.8", "99.0", "", "", "", "", "97.3"]} -{"pcdb_id": 10310, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "12i System", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 12.0, "final_year_of_manufacture": 2015, "raw": ["010310", "000035", "0", "2020/Sep/08 09:22", "Worcester Bosch Group", "Worcester", "Greenstar", "12i System", "41-311-67", "2005", "2015", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "12", "12", "", "", "88.1", "79.1", "", "57.7", "", "2", "", "", "102", "1", "2", "140", "5", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0305", "", "", "", "", "", "", "", "", "87.8", "97.0", "", "", "", "", "95.3"]} -{"pcdb_id": 10311, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "12i System", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 12.0, "final_year_of_manufacture": 2015, "raw": ["010311", "000035", "0", "2020/Sep/08 09:22", "Worcester Bosch Group", "Worcester", "Greenstar", "12i System", "41-311-69", "2005", "2015", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "12", "12", "", "", "89.1", "80.1", "", "58.5", "", "2", "1", "", "102", "1", "2", "140", "5", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0305", "", "", "", "", "", "", "", "", "89.7", "99.2", "", "", "", "", "97.4"]} -{"pcdb_id": 10312, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "24i System", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 24.0, "final_year_of_manufacture": 2015, "raw": ["010312", "000035", "0", "2020/Sep/08 09:23", "Worcester Bosch Group", "Worcester", "Greenstar", "24i System", "41-311-68", "2005", "2015", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24", "24", "", "", "88.5", "79.5", "", "58.0", "", "2", "", "", "102", "1", "2", "140", "5", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0305", "", "", "", "", "", "", "", "", "88.0", "97.9", "", "", "", "", "96.1"]} -{"pcdb_id": 10313, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "24i System", "winter_efficiency_pct": 89.5, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 58.8, "output_kw_max": 24.0, "final_year_of_manufacture": 2015, "raw": ["010313", "000035", "0", "2020/Sep/08 09:23", "Worcester Bosch Group", "Worcester", "Greenstar", "24i System", "41-311-70", "2005", "2015", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "24", "24", "", "", "89.5", "80.5", "", "58.8", "", "2", "1", "", "102", "1", "2", "140", "5", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0305", "", "", "", "", "", "", "", "", "90.0", "100.1", "", "", "", "", "98.2"]} -{"pcdb_id": 10314, "brand_name": "Potterton", "model_name": "Promax System", "model_qualifier": "24 HE Plus", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 24.0, "final_year_of_manufacture": 2008, "raw": ["010314", "000005", "0", "2012/Mar/27 10:12", "Baxi Potterton", "Potterton", "Promax System", "24 HE Plus", "GC No. 41-601-21", "2005", "2008", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24", "24", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "96.9", "", "", "", "", "95.1"]} -{"pcdb_id": 10315, "brand_name": "Potterton", "model_name": "Promax Combi", "model_qualifier": "28 HE Plus", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 55.8, "output_kw_max": 24.0, "final_year_of_manufacture": 2008, "raw": ["010315", "000005", "0", "2010/Nov/19 09:19", "Baxi Potterton", "Potterton", "Promax Combi", "28 HE Plus", "GC No. 47-590-04", "2005", "2008", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "88.0", "79.4", "", "55.8", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "96.9", "", "", "", "", "95.2"]} -{"pcdb_id": 10316, "brand_name": "Potterton", "model_name": "Promax Combi", "model_qualifier": "33 HE Plus", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 55.8, "output_kw_max": 28.0, "final_year_of_manufacture": 2008, "raw": ["010316", "000005", "0", "2010/Nov/19 09:19", "Baxi Potterton", "Potterton", "Promax Combi", "33 HE Plus", "GC No. 47-590-03", "2005", "2008", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28", "28", "", "", "87.9", "79.3", "", "55.8", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "96.7", "", "", "", "", "95.0"]} -{"pcdb_id": 10317, "brand_name": "Vaillant", "model_name": "Ecotec Plus", "model_qualifier": "618 LPG", "winter_efficiency_pct": 89.3, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 19.1, "final_year_of_manufacture": 2012, "raw": ["010317", "000031", "0", "2019/Mar/04 09:14", "Vaillant", "Vaillant", "Ecotec Plus", "618 LPG", "", "2005", "2012", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "19.1", "19.1", "", "", "89.3", "80.3", "", "58.6", "", "2", "1", "", "102", "1", "2", "130", "65", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "92.0", "98.8", "", "", "", "", "97.5"]} -{"pcdb_id": 10318, "brand_name": "Vaillant", "model_name": "Ecotec Plus", "model_qualifier": "630 LPG", "winter_efficiency_pct": 89.3, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 31.8, "final_year_of_manufacture": 2012, "raw": ["010318", "000031", "0", "2019/Mar/04 09:16", "Vaillant", "Vaillant", "Ecotec Plus", "630 LPG", "", "2005", "2012", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "31.8", "31.8", "", "", "89.3", "80.3", "", "58.6", "", "2", "1", "", "102", "1", "2", "130", "65", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "92.0", "98.8", "", "", "", "", "97.5"]} -{"pcdb_id": 10319, "brand_name": "Vaillant", "model_name": "Ecotec Plus", "model_qualifier": "831 LPG", "winter_efficiency_pct": 89.3, "summer_efficiency_pct": 80.7, "comparative_hot_water_efficiency_pct": 56.8, "output_kw_max": 25.5, "final_year_of_manufacture": 2012, "raw": ["010319", "000031", "0", "2019/Mar/04 09:18", "Vaillant", "Vaillant", "Ecotec Plus", "831 LPG", "", "2005", "2012", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "25.5", "25.5", "", "", "89.3", "80.7", "", "56.8", "", "2", "1", "", "104", "1", "2", "130", "65", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "92.0", "98.9", "", "", "", "", "97.6"]} -{"pcdb_id": 10320, "brand_name": "Vaillant", "model_name": "Ecotec Plus", "model_qualifier": "612", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 12.7, "final_year_of_manufacture": 2012, "raw": ["010320", "000031", "0", "2019/Mar/04 09:12", "Vaillant", "Vaillant", "Ecotec Plus", "612", "41-044-44", "2004", "2012", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "12.7", "12.7", "", "", "88.3", "79.3", "", "57.9", "", "2", "", "", "102", "1", "2", "130", "65", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.0", "96.7", "", "", "", "", "95.4"]} -{"pcdb_id": 10321, "brand_name": "Vaillant", "model_name": "Ecotec Plus", "model_qualifier": "615", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 15.9, "final_year_of_manufacture": 2012, "raw": ["010321", "000031", "0", "2019/Mar/04 09:12", "Vaillant", "Vaillant", "Ecotec Plus", "615", "41-044-45", "2004", "2012", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "15.9", "15.9", "", "", "88.3", "79.3", "", "57.9", "", "2", "", "", "102", "1", "2", "130", "65", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.0", "96.7", "", "", "", "", "95.4"]} -{"pcdb_id": 10322, "brand_name": "Vaillant", "model_name": "Ecotec Plus", "model_qualifier": "618", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 19.1, "final_year_of_manufacture": 2012, "raw": ["010322", "000031", "0", "2019/Mar/04 09:13", "Vaillant", "Vaillant", "Ecotec Plus", "618", "41-044-46", "2004", "2012", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "19.1", "19.1", "", "", "88.3", "79.3", "", "57.9", "", "2", "", "", "102", "1", "2", "130", "65", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.0", "96.7", "", "", "", "", "95.4"]} -{"pcdb_id": 10323, "brand_name": "Vaillant", "model_name": "Ecotec Plus", "model_qualifier": "624", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 25.5, "final_year_of_manufacture": 2012, "raw": ["010323", "000031", "0", "2019/Mar/04 09:15", "Vaillant", "Vaillant", "Ecotec Plus", "624", "41-044-47", "2004", "2012", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "25.5", "25.5", "", "", "88.2", "79.2", "", "57.9", "", "2", "", "", "102", "1", "2", "130", "65", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.0", "96.6", "", "", "", "", "95.3"]} -{"pcdb_id": 10324, "brand_name": "Vaillant", "model_name": "Ecotec Plus", "model_qualifier": "630", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 31.8, "final_year_of_manufacture": 2012, "raw": ["010324", "000031", "0", "2019/Mar/04 09:16", "Vaillant", "Vaillant", "Ecotec Plus", "630", "41-044-48", "2004", "2012", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "31.8", "31.8", "", "", "88.3", "79.3", "", "57.9", "", "2", "", "", "102", "1", "2", "130", "65", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.0", "96.7", "", "", "", "", "95.4"]} -{"pcdb_id": 10326, "brand_name": "Vaillant", "model_name": "Ecotec Plus", "model_qualifier": "824", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 62.2, "output_kw_max": 20.2, "final_year_of_manufacture": 2012, "raw": ["010326", "000031", "0", "2019/Mar/04 09:17", "Vaillant", "Vaillant", "Ecotec Plus", "824", "47-044-31", "2004", "2012", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "20.2", "20.2", "", "", "88.3", "79.7", "", "62.2", "", "2", "", "", "104", "1", "2", "130", "65", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "", "0005", "", "", "", "", "", "", "", "", "90.1", "96.7", "", "", "", "", "95.4"]} -{"pcdb_id": 10327, "brand_name": "Vaillant", "model_name": "Ecotec Plus", "model_qualifier": "831", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 62.2, "output_kw_max": 25.5, "final_year_of_manufacture": 2012, "raw": ["010327", "000031", "0", "2019/Mar/04 09:18", "Vaillant", "Vaillant", "Ecotec Plus", "831", "47-044-32", "2004", "2012", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "25.5", "25.5", "", "", "88.3", "79.7", "", "62.2", "", "2", "", "", "104", "1", "2", "130", "65", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "", "0005", "", "", "", "", "", "", "", "", "90.0", "96.8", "", "", "", "", "95.5"]} -{"pcdb_id": 10328, "brand_name": "Vaillant", "model_name": "Ecotec Pro", "model_qualifier": "28", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 62.2, "output_kw_max": 25.5, "final_year_of_manufacture": 2012, "raw": ["010328", "000031", "0", "2019/Mar/04 10:24", "Vaillant", "Vaillant", "Ecotec Pro", "28", "47-044-30", "2004", "2012", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "25.5", "25.5", "", "", "88.2", "79.6", "", "62.2", "", "2", "", "", "104", "1", "2", "130", "65", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "", "0005", "", "", "", "", "", "", "", "", "90.0", "96.6", "", "", "", "", "95.3"]} -{"pcdb_id": 10330, "brand_name": "Kidd VHE", "model_name": "1", "model_qualifier": "Natural Gas", "winter_efficiency_pct": 84.0, "summer_efficiency_pct": 76.4, "comparative_hot_water_efficiency_pct": 55.8, "output_kw_max": 27.2, "final_year_of_manufacture": null, "raw": ["010330", "000204", "0", "2012/Mar/27 10:12", "Archie Kidd (Thermal)", "Kidd VHE", "1", "Natural Gas", "", "", "current", "1", "1", "1", "1", "0", "", "", "2", "3", "2", "17.6", "27.2", "", "", "84.0", "76.4", "", "55.8", "", "2", "", "", "101", "1", "1", "75", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "86.2", "91.0", "", "", "", "", "90.1"]} -{"pcdb_id": 10331, "brand_name": "Kidd VHE", "model_name": "260", "model_qualifier": "Natural Gas", "winter_efficiency_pct": 84.3, "summer_efficiency_pct": 76.7, "comparative_hot_water_efficiency_pct": 56.0, "output_kw_max": null, "final_year_of_manufacture": null, "raw": ["010331", "000204", "0", "2012/Mar/27 10:12", "Archie Kidd (Thermal)", "Kidd VHE", "260", "Natural Gas", "", "", "current", "1", "1", "1", "1", "0", "", "", "2", "3", "2", "58.6", ">70kW", "", "", "84.3", "76.7", "", "56.0", "", "2", "", "", "101", "1", "1", "75", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "87.3", "91.2", "", "", "", "", "90.4"]} -{"pcdb_id": 10333, "brand_name": "Kidd VHE", "model_name": "2", "model_qualifier": "Kerosene", "winter_efficiency_pct": 86.8, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 47.0, "final_year_of_manufacture": null, "raw": ["010333", "000204", "0", "2012/Mar/27 10:12", "Archie Kidd (Thermal)", "Kidd VHE", "2", "Kerosene", "", "", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "29.3", "47", "", "", "86.8", "79.0", "", "57.7", "", "2", "", "", "201", "1", "1", "90", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "89.8", "92.2", "", "", "", "", "91.7"]} -{"pcdb_id": 10334, "brand_name": "Kidd VHE", "model_name": "260", "model_qualifier": "Kerosene", "winter_efficiency_pct": 86.4, "summer_efficiency_pct": 78.6, "comparative_hot_water_efficiency_pct": 57.4, "output_kw_max": null, "final_year_of_manufacture": null, "raw": ["010334", "000204", "0", "2012/Mar/27 10:12", "Archie Kidd (Thermal)", "Kidd VHE", "260", "Kerosene", "", "", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "58.6", ">70kW", "", "", "86.4", "78.6", "", "57.4", "", "2", "", "", "201", "1", "1", "125", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "88.7", "92.2", "", "", "", "", "91.5"]} -{"pcdb_id": 10336, "brand_name": "Viessmann", "model_name": "Vitodens 100", "model_qualifier": "WB1A - 24kW", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 24.0, "final_year_of_manufacture": 2007, "raw": ["010336", "000033", "0", "2012/Mar/27 10:12", "Viessmann", "Viessmann", "Vitodens 100", "WB1A - 24kW", "", "", "2007", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24", "24", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "165", "11", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "97.9", "", "", "", "", "96.0"]} -{"pcdb_id": 10337, "brand_name": "Viessmann", "model_name": "Vitodens 100 Combi", "model_qualifier": "WB1A 24kw", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 56.1, "output_kw_max": 24.0, "final_year_of_manufacture": 2007, "raw": ["010337", "000033", "0", "2006/Jan/17 12:31", "Viessmann", "Viessmann", "Vitodens 100 Combi", "WB1A 24kw", "", "", "2007", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "88.4", "79.8", "", "56.1", "", "2", "", "", "104", "1", "2", "165", "11", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "97.9", "", "", "", "", "96.0"]} -{"pcdb_id": 10338, "brand_name": "Viessmann", "model_name": "Vitodens 100 Combi", "model_qualifier": "WB1A - 30kW", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 56.3, "output_kw_max": 30.0, "final_year_of_manufacture": 2007, "raw": ["010338", "000033", "0", "2006/Jan/17 12:31", "Viessmann", "Viessmann", "Vitodens 100 Combi", "WB1A - 30kW", "", "", "2007", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "30", "30", "", "", "88.6", "80.0", "", "56.3", "", "2", "", "", "104", "1", "2", "165", "11", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "98.3", "", "", "", "", "96.3"]} -{"pcdb_id": 10339, "brand_name": "Grant", "model_name": "Vortex Condensing", "model_qualifier": "Combi 36", "winter_efficiency_pct": 90.5, "summer_efficiency_pct": 84.4, "comparative_hot_water_efficiency_pct": 46.2, "output_kw_max": 36.0, "final_year_of_manufacture": null, "raw": ["010339", "000048", "0", "2024/Jan/31 10:17", "Grant Engineering", "Grant", "Vortex Condensing", "Combi 36", "", "2005", "current", "4", "1", "1", "2", "0", "", "", "2", "3", "2", "36", "36", "", "", "90.5", "84.4", "", "46.2", "", "2", "", "", "203", "1", "1", "", "", "1", "", "", "40", "0", "25", "3", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "0", "", "0003", "", "", "", "", "", "", "", "", "95.1", "99.3", "", "", "", "", "98.5"]} -{"pcdb_id": 10340, "brand_name": "Grant", "model_name": "Vortex Condensing", "model_qualifier": "Combi 26", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 83.0, "comparative_hot_water_efficiency_pct": 45.4, "output_kw_max": 26.0, "final_year_of_manufacture": null, "raw": ["010340", "000048", "0", "2024/Jan/31 10:17", "Grant Engineering", "Grant", "Vortex Condensing", "Combi 26", "", "2005", "current", "4", "1", "1", "2", "0", "", "", "2", "3", "2", "26", "26", "", "", "89.1", "83.0", "", "45.4", "", "2", "", "", "203", "1", "1", "", "", "1", "", "", "40", "0", "25", "3", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "93.6", "96.4", "", "", "", "", "95.9"]} -{"pcdb_id": 10341, "brand_name": "Grant", "model_name": "Outdoor", "model_qualifier": "Combi Max", "winter_efficiency_pct": 83.2, "summer_efficiency_pct": 73.7, "comparative_hot_water_efficiency_pct": 51.8, "output_kw_max": 33.3, "final_year_of_manufacture": null, "raw": ["010341", "000048", "0", "2005/May/31 11:57", "Grant Engineering", "Grant", "Outdoor", "Combi Max", "", "2005", "current", "4", "1", "2", "2", "0", "", "", "1", "3", "2", "33.3", "33.3", "", "", "83.2", "73.7", "", "51.8", "", "2", "", "", "202", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "84.8", "85.2", "", "", "", "", "85.1"]} -{"pcdb_id": 10342, "brand_name": "Grant", "model_name": "Combi Max", "model_qualifier": "", "winter_efficiency_pct": 83.2, "summer_efficiency_pct": 73.7, "comparative_hot_water_efficiency_pct": 51.8, "output_kw_max": 33.3, "final_year_of_manufacture": null, "raw": ["010342", "000048", "0", "2005/May/31 11:57", "Grant Engineering", "Grant", "Combi Max", "", "", "2005", "current", "4", "1", "1", "2", "0", "", "", "1", "3", "2", "33.3", "33.3", "", "", "83.2", "73.7", "", "51.8", "", "2", "", "", "202", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "84.8", "85.2", "", "", "", "", "85.1"]} -{"pcdb_id": 10343, "brand_name": "Grant", "model_name": "Outdoor", "model_qualifier": "Combi 90 V3", "winter_efficiency_pct": 83.7, "summer_efficiency_pct": 74.2, "comparative_hot_water_efficiency_pct": 52.1, "output_kw_max": 26.4, "final_year_of_manufacture": null, "raw": ["010343", "000048", "0", "2005/Jun/09 17:48", "Grant Engineering", "Grant", "Outdoor", "Combi 90 V3", "", "2005", "current", "4", "1", "2", "2", "0", "", "", "1", "3", "2", "26.4", "26.4", "", "", "83.7", "74.2", "", "52.1", "", "2", "", "", "202", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.6", "84.7", "", "", "", "", "85.1"]} -{"pcdb_id": 10344, "brand_name": "Grant", "model_name": "Combi 90 V3", "model_qualifier": "", "winter_efficiency_pct": 83.7, "summer_efficiency_pct": 74.2, "comparative_hot_water_efficiency_pct": 52.1, "output_kw_max": 26.4, "final_year_of_manufacture": null, "raw": ["010344", "000048", "0", "2005/Jun/09 17:48", "Grant Engineering", "Grant", "Combi 90 V3", "", "", "2005", "current", "4", "1", "1", "2", "0", "", "", "1", "3", "2", "26.4", "26.4", "", "", "83.7", "74.2", "", "52.1", "", "2", "", "", "202", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.6", "84.7", "", "", "", "", "85.1"]} -{"pcdb_id": 10345, "brand_name": "Grant", "model_name": "Combi", "model_qualifier": "70 V3", "winter_efficiency_pct": 84.0, "summer_efficiency_pct": 74.5, "comparative_hot_water_efficiency_pct": 52.4, "output_kw_max": 20.5, "final_year_of_manufacture": null, "raw": ["010345", "000048", "0", "2005/May/31 11:58", "Grant Engineering", "Grant", "Combi", "70 V3", "", "2005", "current", "4", "1", "1", "2", "0", "", "", "1", "3", "2", "20.5", "20.5", "", "", "84.0", "74.5", "", "52.4", "", "2", "", "", "202", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.3", "86.3", "", "", "", "", "86.1"]} -{"pcdb_id": 10346, "brand_name": "Potterton", "model_name": "Promax", "model_qualifier": "30 HE Plus", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 30.18, "final_year_of_manufacture": 2010, "raw": ["010346", "000005", "0", "2012/Mar/27 10:12", "Baxi Potterton", "Potterton", "Promax", "30 HE Plus", "GC No. 41-601-22", "2005", "2010", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "30.18", "30.18", "", "", "88.1", "79.1", "", "57.8", "", "2", "", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.4", "96.4", "", "", "", "", "95.1"]} -{"pcdb_id": 10347, "brand_name": "Worcester", "model_name": "Greenstar Utility", "model_qualifier": "50/70-000-GB", "winter_efficiency_pct": 87.7, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 70.0, "final_year_of_manufacture": 2015, "raw": ["010347", "000035", "0", "2020/Sep/08 09:23", "Worcester Heat Systems", "Worcester", "Greenstar Utility", "50/70-000-GB", "", "2005", "2015", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "50", "70", "", "", "87.7", "79.9", "", "58.4", "", "2", "", "", "201", "1", "1", "220", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.0", "94.0", "", "", "", "", "93.4"]} -{"pcdb_id": 10348, "brand_name": "Worcester", "model_name": "Greenstar Utility", "model_qualifier": "32/50-000-GB", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 50.0, "final_year_of_manufacture": 2015, "raw": ["010348", "000035", "0", "2020/Sep/08 09:23", "Worcester Heat Systems", "Worcester", "Greenstar Utility", "32/50-000-GB", "", "2005", "2015", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "32", "50", "", "", "87.9", "80.1", "", "58.5", "", "2", "", "", "201", "1", "1", "190", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.6", "94.3", "", "", "", "", "93.8"]} -{"pcdb_id": 10349, "brand_name": "Ideal", "model_name": "mini", "model_qualifier": "HE C24 LPG", "winter_efficiency_pct": 86.2, "summer_efficiency_pct": 77.6, "comparative_hot_water_efficiency_pct": 54.5, "output_kw_max": 23.7, "final_year_of_manufacture": 2011, "raw": ["010349", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "mini", "HE C24 LPG", "47-348-38", "2004", "2011", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "23.7", "23.7", "", "", "86.2", "77.6", "", "54.5", "", "2", "0", "", "104", "1", "2", "140", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.3", "90.8", "", "", "", "", "90.1"]} -{"pcdb_id": 10350, "brand_name": "Ideal", "model_name": "mini", "model_qualifier": "HE C28 LPG", "winter_efficiency_pct": 86.3, "summer_efficiency_pct": 77.7, "comparative_hot_water_efficiency_pct": 54.6, "output_kw_max": 27.4, "final_year_of_manufacture": 2011, "raw": ["010350", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "mini", "HE C28 LPG", "47-348-39", "2004", "2011", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "27.4", "27.4", "", "", "86.3", "77.7", "", "54.6", "", "2", "0", "", "104", "1", "2", "150", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.1", "91.4", "", "", "", "", "90.6"]} -{"pcdb_id": 10352, "brand_name": "Worcester", "model_name": "Greenstar Cdi", "model_qualifier": "40 Cdi", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 56.4, "output_kw_max": 30.0, "final_year_of_manufacture": 2007, "raw": ["010352", "000035", "0", "2020/Sep/08 09:23", "Worcester Bosch Group", "Worcester", "Greenstar Cdi", "40 Cdi", "47-311-95", "2005", "2007", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "30.0", "30.0", "", "", "88.8", "80.2", "", "56.4", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0305", "", "", "", "", "", "", "", "", "88.1", "98.8", "", "", "", "", "96.8"]} -{"pcdb_id": 10353, "brand_name": "Worcester", "model_name": "Greenstar Cdi", "model_qualifier": "40 Cdi", "winter_efficiency_pct": 89.8, "summer_efficiency_pct": 81.2, "comparative_hot_water_efficiency_pct": 57.1, "output_kw_max": 30.0, "final_year_of_manufacture": 2007, "raw": ["010353", "000035", "0", "2020/Sep/08 09:24", "Worcester Bosch Group", "Worcester", "Greenstar Cdi", "40 Cdi", "47-406-01", "2005", "2007", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "30", "30", "", "", "89.8", "81.2", "", "57.1", "", "2", "1", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0305", "", "", "", "", "", "", "", "", "90.1", "101.0", "", "", "", "", "99.0"]} -{"pcdb_id": 10354, "brand_name": "Worcester", "model_name": "Greenstar Cdi", "model_qualifier": "40 Cdi Conventional", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 40.8, "final_year_of_manufacture": 2014, "raw": ["010354", "000035", "0", "2020/Sep/08 09:24", "Worcester Bosch Group", "Worcester", "Greenstar Cdi", "40 Cdi Conventional", "41-311-72", "2005", "2014", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "40.8", "40.8", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "97.9", "", "", "", "", "96.0"]} -{"pcdb_id": 10355, "brand_name": "Worcester", "model_name": "Greenstar Cdi", "model_qualifier": "40 Cdi Conventional", "winter_efficiency_pct": 89.5, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 58.8, "output_kw_max": 40.8, "final_year_of_manufacture": 2014, "raw": ["010355", "000035", "0", "2020/Sep/08 09:24", "Worcester Bosch Group", "Worcester", "Greenstar Cdi", "40 Cdi Conventional", "41-311-74", "2005", "2014", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "40.8", "40.8", "", "", "89.5", "80.5", "", "58.8", "", "2", "1", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.9", "100.1", "", "", "", "", "98.2"]} -{"pcdb_id": 10356, "brand_name": "Worcester", "model_name": "Greenstar Cdi", "model_qualifier": "30 Cdi Conventional", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 30.0, "final_year_of_manufacture": 2014, "raw": ["010356", "000035", "0", "2020/Sep/08 09:24", "Worcester Bosch Group", "Worcester", "Greenstar Cdi", "30 Cdi Conventional", "41-311-71", "2005", "2014", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "30.0", "30.0", "", "", "88.8", "79.8", "", "58.3", "", "2", "", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.1", "98.8", "", "", "", "", "96.8"]} -{"pcdb_id": 10357, "brand_name": "Worcester", "model_name": "Greenstar Cdi", "model_qualifier": "30 Cdi Conventional", "winter_efficiency_pct": 89.8, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 59.1, "output_kw_max": 30.0, "final_year_of_manufacture": 2014, "raw": ["010357", "000035", "0", "2020/Sep/08 09:24", "Worcester Bosch Group", "Worcester", "Greenstar Cdi", "30 Cdi Conventional", "41-311-73", "2005", "2014", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "30", "30", "", "", "89.8", "80.8", "", "59.1", "", "2", "1", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.1", "101.0", "", "", "", "", "99.0"]} -{"pcdb_id": 10359, "brand_name": "Ravenheat", "model_name": "CSI systemT Low Nox", "model_qualifier": "Timeclock Natural Gas", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 25.74, "final_year_of_manufacture": null, "raw": ["010359", "000026", "0", "2012/Mar/27 10:12", "Ravenheat Manufacturing", "Ravenheat", "CSI systemT Low Nox", "Timeclock Natural Gas", "", "2005", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "25.74", "25.74", "", "", "88.8", "79.8", "", "58.3", "", "2", "", "", "102", "1", "2", "40", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.2", "98.4", "", "", "", "", "96.6"]} -{"pcdb_id": 10360, "brand_name": "Ravenheat", "model_name": "CSI system Low Nox", "model_qualifier": "Natural Gas", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 25.87, "final_year_of_manufacture": null, "raw": ["010360", "000026", "0", "2012/Mar/27 10:12", "Ravenheat Manufacturing", "Ravenheat", "CSI system Low Nox", "Natural Gas", "", "2005", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "25.87", "25.87", "", "", "88.8", "79.8", "", "58.3", "", "2", "", "", "102", "1", "2", "40", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.2", "98.4", "", "", "", "", "96.6"]} -{"pcdb_id": 10361, "brand_name": "Ravenheat", "model_name": "CSI primary Low Nox", "model_qualifier": "Natural Gas", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 25.87, "final_year_of_manufacture": null, "raw": ["010361", "000026", "0", "2012/Mar/27 10:12", "Ravenheat Manufacturing", "Ravenheat", "CSI primary Low Nox", "Natural Gas", "", "2005", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "25.87", "25.87", "", "", "88.8", "79.8", "", "58.3", "", "2", "", "", "102", "1", "2", "40", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.2", "98.4", "", "", "", "", "96.6"]} -{"pcdb_id": 10362, "brand_name": "Ravenheat", "model_name": "CSI 120T Low Nox", "model_qualifier": "Timeclock Natural Gas", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 56.4, "output_kw_max": 25.87, "final_year_of_manufacture": null, "raw": ["010362", "000026", "0", "2010/Sep/29 12:16", "Ravenheat Manufacturing", "Ravenheat", "CSI 120T Low Nox", "Timeclock Natural Gas", "", "2005", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "25.87", "25.87", "", "", "88.8", "80.2", "", "56.4", "", "2", "", "", "104", "1", "2", "160", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.2", "98.4", "", "", "", "", "96.6"]} -{"pcdb_id": 10363, "brand_name": "Ravenheat", "model_name": "CSI 120 Low Nox", "model_qualifier": "Natural Gas", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 56.4, "output_kw_max": 25.87, "final_year_of_manufacture": null, "raw": ["010363", "000026", "0", "2010/Sep/29 12:16", "Ravenheat Manufacturing", "Ravenheat", "CSI 120 Low Nox", "Natural Gas", "", "2005", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "25.87", "25.87", "", "", "88.8", "80.2", "", "56.4", "", "2", "", "", "104", "1", "2", "160", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.2", "98.4", "", "", "", "", "96.6"]} -{"pcdb_id": 10370, "brand_name": "Wolf", "model_name": "CGB-K-20", "model_qualifier": "", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 80.6, "comparative_hot_water_efficiency_pct": 56.7, "output_kw_max": 20.5, "final_year_of_manufacture": null, "raw": ["010370", "000240", "0", "2006/Mar/29 12:49", "Wolf", "Wolf", "CGB-K-20", "", "8611310", "2003", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "20.5", "20.5", "", "", "89.2", "80.6", "", "56.7", "", "2", "1", "", "104", "1", "2", "22", "7", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.1", "99.4", "", "", "", "", "97.6"]} -{"pcdb_id": 10371, "brand_name": "Wolf", "model_name": "CGB-20", "model_qualifier": "", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 20.5, "final_year_of_manufacture": null, "raw": ["010371", "000240", "0", "2012/Mar/27 10:12", "Wolf", "Wolf", "CGB-20", "", "8611308", "2003", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "20.5", "20.5", "", "", "89.2", "80.2", "", "58.6", "", "2", "1", "", "102", "1", "2", "22", "7", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.1", "99.4", "", "", "", "", "97.6"]} -{"pcdb_id": 10372, "brand_name": "Wolf", "model_name": "CGB-K-24", "model_qualifier": "", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 56.6, "output_kw_max": 24.8, "final_year_of_manufacture": null, "raw": ["010372", "000240", "0", "2006/Mar/29 12:50", "Wolf", "Wolf", "CGB-K-24", "", "8611314", "2004", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24.8", "24.8", "", "", "89.1", "80.5", "", "56.6", "", "2", "1", "", "104", "1", "2", "18", "7", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.9", "99.3", "", "", "", "", "97.5"]} -{"pcdb_id": 10373, "brand_name": "Wolf", "model_name": "CGB-24", "model_qualifier": "", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 56.6, "output_kw_max": 24.8, "final_year_of_manufacture": null, "raw": ["010373", "000240", "0", "2006/Mar/29 12:51", "Wolf", "Wolf", "CGB-24", "", "8611312", "2004", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24.8", "24.8", "", "", "89.1", "80.5", "", "56.6", "", "2", "1", "", "104", "1", "2", "18", "7", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.9", "99.3", "", "", "", "", "97.5"]} -{"pcdb_id": 10374, "brand_name": "Wolf", "model_name": "CGB-K-20", "model_qualifier": "", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 56.0, "output_kw_max": 20.5, "final_year_of_manufacture": null, "raw": ["010374", "000240", "0", "2006/Mar/29 12:46", "Wolf", "Wolf", "CGB-K-20", "", "8611309", "2003", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "20.5", "20.5", "", "", "88.2", "79.6", "", "56.0", "", "2", "", "", "104", "1", "2", "22", "7", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.1", "97.2", "", "", "", "", "95.5"]} -{"pcdb_id": 10375, "brand_name": "Wolf", "model_name": "CGB-20", "model_qualifier": "", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 20.5, "final_year_of_manufacture": null, "raw": ["010375", "000240", "0", "2012/Mar/27 10:12", "Wolf", "Wolf", "CGB-20", "", "8611307", "2003", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "20.5", "20.5", "", "", "88.2", "79.2", "", "57.8", "", "2", "", "", "102", "1", "2", "22", "7", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.1", "97.2", "", "", "", "", "95.5"]} -{"pcdb_id": 10376, "brand_name": "Wolf", "model_name": "CGB-K-24", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 55.9, "output_kw_max": 24.8, "final_year_of_manufacture": null, "raw": ["010376", "000240", "0", "2006/Mar/29 12:47", "Wolf", "Wolf", "CGB-K-24", "", "8611313", "2004", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.8", "24.8", "", "", "88.1", "79.5", "", "55.9", "", "2", "", "", "104", "1", "2", "18", "7", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "97.1", "", "", "", "", "95.4"]} -{"pcdb_id": 10377, "brand_name": "Wolf", "model_name": "CGB-24", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 24.8, "final_year_of_manufacture": null, "raw": ["010377", "000240", "0", "2012/Mar/27 10:12", "Wolf", "Wolf", "CGB-24", "", "8611311", "2004", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24.8", "24.8", "", "", "88.1", "79.1", "", "57.8", "", "2", "", "", "102", "1", "2", "18", "7", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "97.1", "", "", "", "", "95.4"]} -{"pcdb_id": 10378, "brand_name": "Wolf", "model_name": "CGB-11", "model_qualifier": "", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 10.9, "final_year_of_manufacture": null, "raw": ["010378", "000240", "0", "2012/Mar/27 10:12", "Wolf", "Wolf", "CGB-11", "", "8611306", "2004", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "10.9", "10.9", "", "", "88.2", "79.2", "", "57.9", "", "2", "", "", "102", "1", "2", "15", "7", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "97.4", "", "", "", "", "95.6"]} -{"pcdb_id": 10379, "brand_name": "Wolf", "model_name": "TGG-18", "model_qualifier": "Topline Boiler", "winter_efficiency_pct": 83.3, "summer_efficiency_pct": 72.6, "comparative_hot_water_efficiency_pct": 53.0, "output_kw_max": 18.0, "final_year_of_manufacture": null, "raw": ["010379", "000240", "0", "2012/Mar/27 10:12", "Wolf", "Wolf", "TGG-18", "Topline Boiler", "8602756", "2001", "current", "2", "2", "1", "1", "0", "", "", "1", "2", "2", "18.0", "18.0", "", "", "83.3", "72.6", "", "53.0", "", "2", "1", "", "102", "1", "2", "44", "8", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "84.8", "84.9", "", "", "", "", "84.9"]} -{"pcdb_id": 10381, "brand_name": "Wolf", "model_name": "TGG-K-18", "model_qualifier": "Topline Combi Boiler", "winter_efficiency_pct": 83.1, "summer_efficiency_pct": 73.0, "comparative_hot_water_efficiency_pct": 51.3, "output_kw_max": 18.0, "final_year_of_manufacture": null, "raw": ["010381", "000240", "0", "2006/Jan/17 12:31", "Wolf", "Wolf", "TGG-K-18", "Topline Combi Boiler", "8602754", "2001", "current", "2", "2", "1", "2", "0", "", "", "1", "2", "2", "18.0", "18.0", "", "", "83.1", "73.0", "", "51.3", "", "2", "1", "", "104", "1", "2", "44", "8", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "84.7", "84.9", "", "", "", "", "84.9"]} -{"pcdb_id": 10382, "brand_name": "Wolf", "model_name": "TGG-K-24", "model_qualifier": "Topline Combi Boiler", "winter_efficiency_pct": 83.1, "summer_efficiency_pct": 73.0, "comparative_hot_water_efficiency_pct": 51.3, "output_kw_max": 24.0, "final_year_of_manufacture": null, "raw": ["010382", "000240", "0", "2006/Jan/17 12:31", "Wolf", "Wolf", "TGG-K-24", "Topline Combi Boiler", "8602760", "2001", "current", "2", "2", "1", "2", "0", "", "", "1", "2", "2", "24.0", "24.0", "", "", "83.1", "73.0", "", "51.3", "", "2", "1", "", "104", "1", "2", "44", "8", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "84.7", "84.8", "", "", "", "", "84.8"]} -{"pcdb_id": 10383, "brand_name": "Wolf", "model_name": "TGG-24", "model_qualifier": "Topline Boiler", "winter_efficiency_pct": 83.3, "summer_efficiency_pct": 72.6, "comparative_hot_water_efficiency_pct": 53.0, "output_kw_max": 24.0, "final_year_of_manufacture": null, "raw": ["010383", "000240", "0", "2012/Mar/27 10:12", "Wolf", "Wolf", "TGG-24", "Topline Boiler", "8602760", "2001", "current", "2", "2", "1", "1", "0", "", "", "1", "2", "2", "24.0", "24.0", "", "", "83.3", "72.6", "", "53.0", "", "2", "1", "", "102", "1", "2", "44", "8", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "84.7", "84.8", "", "", "", "", "84.8"]} -{"pcdb_id": 10384, "brand_name": "Wolf", "model_name": "TGG-K-18", "model_qualifier": "Topline Combi Boiler", "winter_efficiency_pct": 81.8, "summer_efficiency_pct": 71.7, "comparative_hot_water_efficiency_pct": 50.4, "output_kw_max": 18.0, "final_year_of_manufacture": null, "raw": ["010384", "000240", "0", "2006/Jan/17 12:31", "Wolf", "Wolf", "TGG-K-18", "Topline Combi Boiler", "8602753", "2001", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "18.0", "18.0", "", "", "81.8", "71.7", "", "50.4", "", "2", "", "", "104", "1", "2", "44", "8", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.9", "83.1", "", "", "", "", "83.0"]} -{"pcdb_id": 10385, "brand_name": "Wolf", "model_name": "TGG-18", "model_qualifier": "Topline Boiler", "winter_efficiency_pct": 82.0, "summer_efficiency_pct": 71.3, "comparative_hot_water_efficiency_pct": 52.1, "output_kw_max": 18.0, "final_year_of_manufacture": null, "raw": ["010385", "000240", "0", "2012/Mar/27 10:12", "Wolf", "Wolf", "TGG-18", "Topline Boiler", "8602755", "2001", "current", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "18.0", "18.0", "", "", "82.0", "71.3", "", "52.1", "", "2", "", "", "102", "1", "2", "44", "8", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.9", "83.1", "", "", "", "", "83.0"]} -{"pcdb_id": 10386, "brand_name": "Wolf", "model_name": "TGG-K-24", "model_qualifier": "Topline Combi Boiler", "winter_efficiency_pct": 81.7, "summer_efficiency_pct": 71.6, "comparative_hot_water_efficiency_pct": 50.4, "output_kw_max": 24.0, "final_year_of_manufacture": null, "raw": ["010386", "000240", "0", "2006/Jan/17 12:31", "Wolf", "Wolf", "TGG-K-24", "Topline Combi Boiler", "8602757", "2001", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "24.0", "24.0", "", "", "81.7", "71.6", "", "50.4", "", "2", "", "", "104", "1", "2", "44", "8", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.9", "83.0", "", "", "", "", "83.0"]} -{"pcdb_id": 10387, "brand_name": "Wolf", "model_name": "TGG-24", "model_qualifier": "Topline Boiler", "winter_efficiency_pct": 81.9, "summer_efficiency_pct": 71.2, "comparative_hot_water_efficiency_pct": 52.0, "output_kw_max": 24.0, "final_year_of_manufacture": null, "raw": ["010387", "000240", "0", "2012/Mar/27 10:12", "Wolf", "Wolf", "TGG-24", "Topline Boiler", "8602759", "2001", "current", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "24.0", "24.0", "", "", "81.9", "71.2", "", "52.0", "", "2", "", "", "102", "1", "2", "44", "8", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.9", "83.0", "", "", "", "", "83.0"]} -{"pcdb_id": 10388, "brand_name": "Ideal", "model_name": "Mexico", "model_qualifier": "HE 36", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 37.0, "final_year_of_manufacture": null, "raw": ["010388", "000008", "0", "2012/Mar/27 10:12", "Ideal Boilers", "Ideal", "Mexico", "HE 36", "41-415-20", "2005", "current", "1", "1", "1", "1", "0", "", "", "2", "2", "2", "37.0", "37.0", "", "", "88.3", "79.3", "", "57.9", "", "2", "", "", "102", "1", "2", "42", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.0", "97.2", "", "", "", "", "95.7"]} -{"pcdb_id": 10389, "brand_name": "Ideal", "model_name": "Mexico", "model_qualifier": "HE 30", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 30.1, "final_year_of_manufacture": null, "raw": ["010389", "000008", "0", "2012/Mar/27 10:12", "Ideal Boilers", "Ideal", "Mexico", "HE 30", "41-429-99", "2005", "current", "1", "1", "1", "1", "0", "", "", "2", "2", "2", "30.1", "30.1", "", "", "88.2", "79.2", "", "57.9", "", "2", "", "", "102", "1", "2", "42", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.5", "97.1", "", "", "", "", "95.5"]} -{"pcdb_id": 10390, "brand_name": "Ideal", "model_name": "Mexico", "model_qualifier": "HE 24", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 23.4, "final_year_of_manufacture": null, "raw": ["010390", "000008", "0", "2012/Mar/27 10:12", "Ideal Boilers", "Ideal", "Mexico", "HE 24", "41-429-98", "2005", "current", "1", "1", "1", "1", "0", "", "", "2", "2", "2", "23.4", "23.4", "", "", "88.1", "79.1", "", "57.8", "", "2", "", "", "102", "1", "2", "38", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "97.1", "", "", "", "", "95.4"]} -{"pcdb_id": 10391, "brand_name": "Ideal", "model_name": "Mexico", "model_qualifier": "HE18", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 18.2, "final_year_of_manufacture": null, "raw": ["010391", "000008", "0", "2012/Mar/27 10:12", "Ideal Boilers", "Ideal", "Mexico", "HE18", "41-429-65", "2005", "current", "1", "1", "1", "1", "0", "", "", "2", "2", "2", "18.2", "18.2", "", "", "88.7", "79.7", "", "58.2", "", "2", "", "", "102", "1", "2", "38", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.2", "98.5", "", "", "", "", "96.5"]} -{"pcdb_id": 10392, "brand_name": "Ideal", "model_name": "Mexico", "model_qualifier": "HE15", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 14.6, "final_year_of_manufacture": null, "raw": ["010392", "000008", "0", "2012/Jun/28 10:57", "Ideal Boilers", "Ideal", "Mexico", "HE15", "41-429-39", "2005", "current", "1", "1", "1", "1", "0", "", "", "2", "2", "2", "14.6", "14.6", "", "", "89.0", "80.0", "", "58.4", "", "2", "", "", "102", "1", "2", "38", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.5", "99.0", "", "", "", "", "97.0"]} -{"pcdb_id": 10393, "brand_name": "Vokera", "model_name": "Linea HE", "model_qualifier": "25HE", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 55.8, "output_kw_max": 24.4, "final_year_of_manufacture": 2010, "raw": ["010393", "000011", "0", "2010/Oct/21 11:11", "Vokera", "Vokera", "Linea HE", "25HE", "4709460", "2005", "2010", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.4", "24.4", "", "", "87.9", "79.3", "", "55.8", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "96.5", "", "", "", "", "94.9"]} -{"pcdb_id": 10394, "brand_name": "Vokera", "model_name": "Linea HE", "model_qualifier": "25HE LPG", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 56.6, "output_kw_max": 24.0, "final_year_of_manufacture": 2010, "raw": ["010394", "000011", "0", "2010/Oct/21 11:11", "Vokera", "Vokera", "Linea HE", "25HE LPG", "4709461", "2005", "2010", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "89.1", "80.5", "", "56.6", "", "2", "0", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.5", "97.2", "", "", "", "", "95.5"]} -{"pcdb_id": 10395, "brand_name": "Vokera", "model_name": "Linea HE", "model_qualifier": "30HE", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 55.9, "output_kw_max": 29.4, "final_year_of_manufacture": 2010, "raw": ["010395", "000011", "0", "2010/Oct/21 11:12", "Vokera", "Vokera", "Linea HE", "30HE", "4709462", "2005", "2010", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "29.4", "29.4", "", "", "88.1", "79.5", "", "55.9", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.4", "96.9", "", "", "", "", "95.3"]} -{"pcdb_id": 10396, "brand_name": "Vokera", "model_name": "Linea HE", "model_qualifier": "30HE LPG", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 56.9, "output_kw_max": 29.0, "final_year_of_manufacture": 2010, "raw": ["010396", "000011", "0", "2010/Oct/21 11:12", "Vokera", "Vokera", "Linea HE", "30HE LPG", "4709463", "2005", "2010", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "29", "29", "", "", "89.4", "80.8", "", "56.9", "", "2", "0", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.0", "97.9", "", "", "", "", "96.2"]} -{"pcdb_id": 10397, "brand_name": "Vokera", "model_name": "Linea HE", "model_qualifier": "35HE", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 56.1, "output_kw_max": 33.7, "final_year_of_manufacture": 2010, "raw": ["010397", "000011", "0", "2010/Oct/21 11:12", "Vokera", "Vokera", "Linea HE", "35HE", "4709464", "2005", "2010", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "33.7", "33.7", "", "", "88.4", "79.8", "", "56.1", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "97.8", "", "", "", "", "95.9"]} -{"pcdb_id": 10398, "brand_name": "Vokera", "model_name": "Linea HE", "model_qualifier": "35HE LPG", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 56.5, "output_kw_max": 33.3, "final_year_of_manufacture": 2010, "raw": ["010398", "000011", "0", "2010/Oct/21 11:13", "Vokera", "Vokera", "Linea HE", "35HE LPG", "4709465", "2005", "2010", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "33.3", "33.3", "", "", "88.9", "80.3", "", "56.5", "", "2", "0", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.5", "96.8", "", "", "", "", "95.2"]} -{"pcdb_id": 10399, "brand_name": "Heating World Group", "model_name": "Grandee Combi Condensing External", "model_qualifier": "W 15/22", "winter_efficiency_pct": 87.4, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 56.2, "output_kw_max": 21.0, "final_year_of_manufacture": null, "raw": ["010399", "000050", "0", "2006/Jul/28 13:39", "Heating World Group", "Heating World Group", "Grandee Combi Condensing External", "W 15/22", "", "2005", "current", "4", "2", "2", "2", "0", "", "", "2", "3", "1", "15", "21", "", "", "87.4", "80.0", "", "56.2", "", "2", "", "", "202", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.4", "93.3", "", "", "", "", "92.8"]} -{"pcdb_id": 10400, "brand_name": "Heating World Group", "model_name": "Grandee System Condensing External", "model_qualifier": "W 15/22", "winter_efficiency_pct": 87.4, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 21.0, "final_year_of_manufacture": null, "raw": ["010400", "000050", "0", "2012/Mar/27 10:12", "Heating World Group", "Heating World Group", "Grandee System Condensing External", "W 15/22", "", "2005", "current", "4", "2", "2", "1", "0", "", "", "2", "3", "1", "15", "21", "", "", "87.4", "79.6", "", "58.1", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.4", "93.3", "", "", "", "", "92.8"]} -{"pcdb_id": 10401, "brand_name": "Heating World Group", "model_name": "Grandee Standard Condensing External", "model_qualifier": "W 15/22", "winter_efficiency_pct": 87.4, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 21.0, "final_year_of_manufacture": null, "raw": ["010401", "000050", "0", "2012/Mar/27 10:12", "Heating World Group", "Heating World Group", "Grandee Standard Condensing External", "W 15/22", "", "2005", "current", "4", "2", "2", "1", "0", "", "", "2", "3", "1", "15", "21", "", "", "87.4", "79.6", "", "58.1", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.4", "93.3", "", "", "", "", "92.8"]} -{"pcdb_id": 10402, "brand_name": "Heating World Group", "model_name": "Grandee Combi Condensing", "model_qualifier": "W 15/22", "winter_efficiency_pct": 87.4, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 56.2, "output_kw_max": 21.0, "final_year_of_manufacture": null, "raw": ["010402", "000050", "0", "2006/Jul/28 13:40", "Heating World Group", "Heating World Group", "Grandee Combi Condensing", "W 15/22", "", "2005", "current", "4", "2", "1", "2", "0", "", "", "2", "3", "1", "15", "21", "", "", "87.4", "80.0", "", "56.2", "", "2", "", "", "202", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.4", "93.3", "", "", "", "", "92.8"]} -{"pcdb_id": 10403, "brand_name": "Heating World Group", "model_name": "Grandee System Condensing", "model_qualifier": "W 15/22", "winter_efficiency_pct": 87.4, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 21.0, "final_year_of_manufacture": null, "raw": ["010403", "000050", "0", "2012/Mar/27 10:12", "Heating World Group", "Heating World Group", "Grandee System Condensing", "W 15/22", "", "2005", "current", "4", "2", "1", "1", "0", "", "", "2", "3", "1", "15", "21", "", "", "87.4", "79.6", "", "58.1", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.4", "93.3", "", "", "", "", "92.8"]} -{"pcdb_id": 10404, "brand_name": "Heating World Group", "model_name": "Grandee Standard Condensing", "model_qualifier": "W 15/22", "winter_efficiency_pct": 87.4, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 21.0, "final_year_of_manufacture": null, "raw": ["010404", "000050", "0", "2012/Mar/27 10:12", "Heating World Group", "Heating World Group", "Grandee Standard Condensing", "W 15/22", "", "2005", "current", "4", "2", "1", "1", "0", "", "", "2", "3", "1", "15", "21", "", "", "87.4", "79.6", "", "58.1", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.4", "93.3", "", "", "", "", "92.8"]} -{"pcdb_id": 10405, "brand_name": "Heating World Group", "model_name": "Grandee Combi Condensing External", "model_qualifier": "W 23/28", "winter_efficiency_pct": 87.0, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 56.0, "output_kw_max": 26.0, "final_year_of_manufacture": null, "raw": ["010405", "000050", "0", "2006/Jul/28 13:41", "Heating World Group", "Heating World Group", "Grandee Combi Condensing External", "W 23/28", "", "2005", "current", "4", "2", "2", "2", "0", "", "", "2", "3", "1", "23", "26", "", "", "87.0", "79.6", "", "56.0", "", "2", "", "", "202", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.1", "92.6", "", "", "", "", "92.1"]} -{"pcdb_id": 10406, "brand_name": "Heating World Group", "model_name": "Grandee System Condensing External", "model_qualifier": "W 23/28", "winter_efficiency_pct": 87.0, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 26.0, "final_year_of_manufacture": null, "raw": ["010406", "000050", "0", "2012/Mar/27 10:12", "Heating World Group", "Heating World Group", "Grandee System Condensing External", "W 23/28", "", "2005", "current", "4", "2", "2", "1", "0", "", "", "2", "3", "1", "23", "26", "", "", "87.0", "79.2", "", "57.9", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.1", "92.6", "", "", "", "", "92.1"]} -{"pcdb_id": 10407, "brand_name": "Heating World Group", "model_name": "Grandee Standard Condensing External", "model_qualifier": "W 23/28", "winter_efficiency_pct": 87.0, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 26.0, "final_year_of_manufacture": null, "raw": ["010407", "000050", "0", "2012/Mar/27 10:12", "Heating World Group", "Heating World Group", "Grandee Standard Condensing External", "W 23/28", "", "2005", "current", "4", "2", "2", "1", "0", "", "", "2", "3", "1", "23", "26", "", "", "87.0", "79.2", "", "57.9", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.1", "92.6", "", "", "", "", "92.1"]} -{"pcdb_id": 10408, "brand_name": "Heating World Group", "model_name": "Grandee Combi Condensing", "model_qualifier": "W 23/28", "winter_efficiency_pct": 87.0, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 56.0, "output_kw_max": 26.0, "final_year_of_manufacture": null, "raw": ["010408", "000050", "0", "2006/Jul/28 13:42", "Heating World Group", "Heating World Group", "Grandee Combi Condensing", "W 23/28", "", "2005", "current", "4", "2", "1", "2", "0", "", "", "2", "3", "1", "23", "26", "", "", "87.0", "79.6", "", "56.0", "", "2", "", "", "202", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.1", "92.6", "", "", "", "", "92.1"]} -{"pcdb_id": 10409, "brand_name": "Heating World Group", "model_name": "Grandee System Condensing", "model_qualifier": "W 23/28", "winter_efficiency_pct": 87.0, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 26.0, "final_year_of_manufacture": null, "raw": ["010409", "000050", "0", "2012/Mar/27 10:12", "Heating World Group", "Heating World Group", "Grandee System Condensing", "W 23/28", "", "2005", "current", "4", "2", "1", "1", "0", "", "", "2", "3", "1", "23", "26", "", "", "87.0", "79.2", "", "57.9", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.1", "92.6", "", "", "", "", "92.1"]} -{"pcdb_id": 10410, "brand_name": "Heating World Group", "model_name": "Grandee Standard Condensing", "model_qualifier": "W 23/28", "winter_efficiency_pct": 87.0, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 26.0, "final_year_of_manufacture": null, "raw": ["010410", "000050", "0", "2012/Mar/27 10:12", "Heating World Group", "Heating World Group", "Grandee Standard Condensing", "W 23/28", "", "2005", "current", "4", "2", "1", "1", "0", "", "", "2", "3", "1", "23", "26", "", "", "87.0", "79.2", "", "57.9", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.1", "92.6", "", "", "", "", "92.1"]} -{"pcdb_id": 10411, "brand_name": "Heating World Group", "model_name": "Grandee Combi Condensing External", "model_qualifier": "FS 15/23", "winter_efficiency_pct": 87.4, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 56.2, "output_kw_max": 21.0, "final_year_of_manufacture": null, "raw": ["010411", "000050", "0", "2006/Jul/28 13:42", "Heating World Group", "Heating World Group", "Grandee Combi Condensing External", "FS 15/23", "", "2005", "current", "4", "2", "2", "2", "0", "", "", "2", "3", "1", "15", "21", "", "", "87.4", "80.0", "", "56.2", "", "2", "", "", "202", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.4", "93.3", "", "", "", "", "92.8"]} -{"pcdb_id": 10412, "brand_name": "Heating World Group", "model_name": "Grandee System Condensing External", "model_qualifier": "FS 15/23", "winter_efficiency_pct": 87.4, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 21.0, "final_year_of_manufacture": null, "raw": ["010412", "000050", "0", "2012/Mar/27 10:12", "Heating World Group", "Heating World Group", "Grandee System Condensing External", "FS 15/23", "", "2005", "current", "4", "2", "1", "1", "0", "", "", "2", "3", "1", "15", "21", "", "", "87.4", "79.6", "", "58.1", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.4", "93.3", "", "", "", "", "92.8"]} -{"pcdb_id": 10413, "brand_name": "Heating World Group", "model_name": "Grandee Standard Condensing External", "model_qualifier": "FS 15/23", "winter_efficiency_pct": 87.4, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 21.0, "final_year_of_manufacture": null, "raw": ["010413", "000050", "0", "2012/Mar/27 10:12", "Heating World Group", "Heating World Group", "Grandee Standard Condensing External", "FS 15/23", "", "2005", "current", "4", "2", "2", "1", "0", "", "", "2", "3", "1", "15", "21", "", "", "87.4", "79.6", "", "58.1", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.4", "93.3", "", "", "", "", "92.8"]} -{"pcdb_id": 10414, "brand_name": "Heating World Group", "model_name": "Grandee Combi Condensing", "model_qualifier": "FS 15/23", "winter_efficiency_pct": 87.4, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 56.2, "output_kw_max": 21.0, "final_year_of_manufacture": null, "raw": ["010414", "000050", "0", "2006/Jul/28 13:43", "Heating World Group", "Heating World Group", "Grandee Combi Condensing", "FS 15/23", "", "2005", "current", "4", "2", "1", "2", "0", "", "", "2", "3", "1", "15", "21", "", "", "87.4", "80.0", "", "56.2", "", "2", "", "", "202", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.4", "93.3", "", "", "", "", "92.8"]} -{"pcdb_id": 10415, "brand_name": "Heating World Group", "model_name": "Grandee System Condensing", "model_qualifier": "FS 15/23", "winter_efficiency_pct": 87.4, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 22.0, "final_year_of_manufacture": null, "raw": ["010415", "000050", "0", "2012/Mar/27 10:12", "Heating World Group", "Heating World Group", "Grandee System Condensing", "FS 15/23", "", "2005", "current", "4", "2", "1", "1", "0", "", "", "2", "3", "1", "15", "22", "", "", "87.4", "79.6", "", "58.1", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.4", "93.3", "", "", "", "", "92.8"]} -{"pcdb_id": 10416, "brand_name": "Heating World Group", "model_name": "Grandee Standard Condensing", "model_qualifier": "FS 15/23", "winter_efficiency_pct": 87.4, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 21.0, "final_year_of_manufacture": null, "raw": ["010416", "000050", "0", "2012/Mar/27 10:12", "Heating World Group", "Heating World Group", "Grandee Standard Condensing", "FS 15/23", "", "2005", "current", "4", "2", "1", "1", "0", "", "", "2", "3", "1", "15", "21", "", "", "87.4", "79.6", "", "58.1", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.4", "93.3", "", "", "", "", "92.8"]} -{"pcdb_id": 10417, "brand_name": "Heating World Group", "model_name": "Grandee Combi Condensing External", "model_qualifier": "FS 23/30", "winter_efficiency_pct": 87.0, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 56.0, "output_kw_max": 26.0, "final_year_of_manufacture": null, "raw": ["010417", "000050", "0", "2006/Jul/28 13:44", "Heating World Group", "Heating World Group", "Grandee Combi Condensing External", "FS 23/30", "", "2005", "current", "4", "2", "2", "2", "0", "", "", "2", "3", "1", "23", "26", "", "", "87.0", "79.6", "", "56.0", "", "2", "", "", "202", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.1", "92.6", "", "", "", "", "92.1"]} -{"pcdb_id": 10418, "brand_name": "Heating World Group", "model_name": "Grandee System Condensing External", "model_qualifier": "FS 23/30", "winter_efficiency_pct": 87.0, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 26.0, "final_year_of_manufacture": null, "raw": ["010418", "000050", "0", "2012/Mar/27 10:12", "Heating World Group", "Heating World Group", "Grandee System Condensing External", "FS 23/30", "", "2005", "current", "4", "2", "2", "1", "0", "", "", "2", "3", "1", "23", "26", "", "", "87.0", "79.2", "", "57.9", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.1", "92.6", "", "", "", "", "92.1"]} -{"pcdb_id": 10419, "brand_name": "Heating World Group", "model_name": "Grandee Standard Condensing External", "model_qualifier": "FS 23/30", "winter_efficiency_pct": 87.0, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 26.0, "final_year_of_manufacture": null, "raw": ["010419", "000050", "0", "2012/Mar/27 10:12", "Heating World Group", "Heating World Group", "Grandee Standard Condensing External", "FS 23/30", "", "2005", "current", "4", "2", "2", "1", "0", "", "", "2", "3", "1", "23", "26", "", "", "87.0", "79.2", "", "57.9", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.1", "92.6", "", "", "", "", "92.1"]} -{"pcdb_id": 10420, "brand_name": "Heating World Group", "model_name": "Grandee Combi Condensing", "model_qualifier": "FS 23/30", "winter_efficiency_pct": 87.0, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 56.0, "output_kw_max": 26.0, "final_year_of_manufacture": null, "raw": ["010420", "000050", "0", "2006/Jul/28 13:44", "Heating World Group", "Heating World Group", "Grandee Combi Condensing", "FS 23/30", "", "2005", "current", "4", "2", "1", "2", "0", "", "", "2", "3", "1", "23", "26", "", "", "87.0", "79.6", "", "56.0", "", "2", "", "", "202", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.1", "92.6", "", "", "", "", "92.1"]} -{"pcdb_id": 10421, "brand_name": "Heating World Group", "model_name": "Grandee System Condensing", "model_qualifier": "FS 23/30", "winter_efficiency_pct": 87.0, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 26.0, "final_year_of_manufacture": null, "raw": ["010421", "000050", "0", "2012/Mar/27 10:12", "Heating World Group", "Heating World Group", "Grandee System Condensing", "FS 23/30", "", "2005", "current", "4", "2", "1", "1", "0", "", "", "2", "3", "1", "23", "26", "", "", "87.0", "79.2", "", "57.9", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.1", "92.6", "", "", "", "", "92.1"]} -{"pcdb_id": 10422, "brand_name": "Heating World Group", "model_name": "Grandee Standard Condensing", "model_qualifier": "FS 23/30", "winter_efficiency_pct": 87.0, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 26.0, "final_year_of_manufacture": null, "raw": ["010422", "000050", "0", "2012/Mar/27 10:12", "Heating World Group", "Heating World Group", "Grandee Standard Condensing", "FS 23/30", "", "2005", "current", "4", "2", "1", "1", "0", "", "", "2", "3", "1", "23", "26", "", "", "87.0", "79.2", "", "57.9", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.1", "92.6", "", "", "", "", "92.1"]} -{"pcdb_id": 10423, "brand_name": "Optia", "model_name": "HE 18", "model_qualifier": "", "winter_efficiency_pct": 85.0, "summer_efficiency_pct": 77.4, "comparative_hot_water_efficiency_pct": 56.6, "output_kw_max": 18.0, "final_year_of_manufacture": null, "raw": ["010423", "000008", "0", "2012/Mar/27 10:12", "Ideal Boilers", "Optia", "HE 18", "", "GC No. 41 421 96", "2005", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18", "18.0", "", "", "85.0", "77.4", "", "56.6", "", "2", "", "", "101", "1", "1", "100", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "86.6", "93.4", "", "", "", "", "92.1"]} -{"pcdb_id": 10424, "brand_name": "Optia", "model_name": "HE 15", "model_qualifier": "", "winter_efficiency_pct": 84.3, "summer_efficiency_pct": 76.7, "comparative_hot_water_efficiency_pct": 56.0, "output_kw_max": 15.0, "final_year_of_manufacture": null, "raw": ["010424", "000008", "0", "2012/Mar/27 10:12", "Ideal Boilers", "Optia", "HE 15", "", "GC No. 41 421 72", "2005", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "15", "15.0", "", "", "84.3", "76.7", "", "56.0", "", "2", "", "", "101", "1", "1", "100", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "85.6", "92.3", "", "", "", "", "91.0"]} -{"pcdb_id": 10425, "brand_name": "Optia", "model_name": "HE 12", "model_qualifier": "", "winter_efficiency_pct": 85.0, "summer_efficiency_pct": 77.4, "comparative_hot_water_efficiency_pct": 56.6, "output_kw_max": 12.0, "final_year_of_manufacture": null, "raw": ["010425", "000008", "0", "2012/Mar/27 10:12", "Ideal Boilers", "Optia", "HE 12", "", "GC No. 41 421 71", "2005", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "12", "12.0", "", "", "85.0", "77.4", "", "56.6", "", "2", "", "", "101", "1", "1", "100", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "85.8", "94.0", "", "", "", "", "92.4"]} -{"pcdb_id": 10426, "brand_name": "Optia", "model_name": "HE 9", "model_qualifier": "", "winter_efficiency_pct": 84.8, "summer_efficiency_pct": 77.2, "comparative_hot_water_efficiency_pct": 56.4, "output_kw_max": 9.0, "final_year_of_manufacture": null, "raw": ["010426", "000008", "0", "2012/Mar/27 10:12", "Ideal Boilers", "Optia", "HE 9", "", "GC No. 41 421 70", "2005", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "9.0", "9.0", "", "", "84.8", "77.2", "", "56.4", "", "2", "", "", "101", "1", "1", "100", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "85.7", "93.4", "", "", "", "", "92.0"]} -{"pcdb_id": 10427, "brand_name": "Ideal", "model_name": "Classic", "model_qualifier": "HE 9", "winter_efficiency_pct": 84.8, "summer_efficiency_pct": 77.2, "comparative_hot_water_efficiency_pct": 56.4, "output_kw_max": 9.0, "final_year_of_manufacture": 2011, "raw": ["010427", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "Classic", "HE 9", "41-415-58", "2005", "2011", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "9", "9.0", "", "", "84.8", "77.2", "", "56.4", "", "2", "", "", "101", "1", "1", "100", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "85.7", "93.4", "", "", "", "", "92.0"]} -{"pcdb_id": 10428, "brand_name": "Ideal", "model_name": "Classic", "model_qualifier": "HE 12", "winter_efficiency_pct": 85.0, "summer_efficiency_pct": 77.4, "comparative_hot_water_efficiency_pct": 56.6, "output_kw_max": 12.0, "final_year_of_manufacture": 2011, "raw": ["010428", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "Classic", "HE 12", "41-415-59", "2005", "2011", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "12", "12.0", "", "", "85.0", "77.4", "", "56.6", "", "2", "", "", "101", "1", "1", "100", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "85.8", "94.0", "", "", "", "", "92.4"]} -{"pcdb_id": 10429, "brand_name": "Ideal", "model_name": "Classic", "model_qualifier": "HE 15", "winter_efficiency_pct": 84.3, "summer_efficiency_pct": 76.7, "comparative_hot_water_efficiency_pct": 56.0, "output_kw_max": 15.0, "final_year_of_manufacture": 2011, "raw": ["010429", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "Classic", "HE 15", "41-421-45", "2005", "2011", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "15", "15.0", "", "", "84.3", "76.7", "", "56.0", "", "2", "", "", "101", "1", "1", "100", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "85.6", "92.3", "", "", "", "", "91.0"]} -{"pcdb_id": 10430, "brand_name": "Ideal", "model_name": "Classic", "model_qualifier": "HE 18", "winter_efficiency_pct": 85.0, "summer_efficiency_pct": 77.4, "comparative_hot_water_efficiency_pct": 56.6, "output_kw_max": 18.0, "final_year_of_manufacture": 2011, "raw": ["010430", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "Classic", "HE 18", "41-421-46", "2005", "2011", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18", "18.0", "", "", "85.0", "77.4", "", "56.6", "", "2", "", "", "101", "1", "1", "100", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "86.6", "93.4", "", "", "", "", "92.1"]} -{"pcdb_id": 10432, "brand_name": "Ferroli", "model_name": "Domicompact", "model_qualifier": "F 30 B", "winter_efficiency_pct": 86.2, "summer_efficiency_pct": 77.6, "comparative_hot_water_efficiency_pct": 54.6, "output_kw_max": 30.0, "final_year_of_manufacture": 2017, "raw": ["010432", "000097", "0", "2017/Aug/07 17:00", "Ferroli SpA", "Ferroli", "Domicompact", "F 30 B", "", "2005", "2017", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "30", "30", "", "", "86.2", "77.6", "", "54.6", "", "2", "", "", "104", "1", "2", "170", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "86.9", "92.7", "", "", "", "", "91.6"]} -{"pcdb_id": 10433, "brand_name": "Ferroli", "model_name": "Domicompact", "model_qualifier": "F 24 B", "winter_efficiency_pct": 86.2, "summer_efficiency_pct": 77.6, "comparative_hot_water_efficiency_pct": 54.6, "output_kw_max": 24.1, "final_year_of_manufacture": 2017, "raw": ["010433", "000097", "0", "2017/Aug/07 17:01", "Ferroli SpA", "Ferroli", "Domicompact", "F 24 B", "", "2005", "2017", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.1", "24.1", "", "", "86.2", "77.6", "", "54.6", "", "2", "", "", "104", "1", "2", "135", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "86.9", "92.7", "", "", "", "", "91.6"]} -{"pcdb_id": 10434, "brand_name": "Ferroli", "model_name": "F 30 B", "model_qualifier": "", "winter_efficiency_pct": 86.2, "summer_efficiency_pct": 77.6, "comparative_hot_water_efficiency_pct": 54.6, "output_kw_max": 30.0, "final_year_of_manufacture": 2008, "raw": ["010434", "000097", "0", "2009/Apr/28 16:09", "Ferroli SpA", "Ferroli", "F 30 B", "", "", "2005", "2008", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "30.0", "30.0", "", "", "86.2", "77.6", "", "54.6", "", "2", "", "", "104", "1", "2", "135", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "", "", "0005", "", "", "", "", "", "", "", "", "86.9", "92.7", "", "", "", "", "91.6"]} -{"pcdb_id": 10435, "brand_name": "Ferroli", "model_name": "F 24 B", "model_qualifier": "", "winter_efficiency_pct": 86.2, "summer_efficiency_pct": 77.6, "comparative_hot_water_efficiency_pct": 54.6, "output_kw_max": 24.1, "final_year_of_manufacture": 2008, "raw": ["010435", "000097", "0", "2009/Apr/28 16:07", "Ferroli SpA", "Ferroli", "F 24 B", "", "", "2005", "2008", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.1", "24.1", "", "", "86.2", "77.6", "", "54.6", "", "2", "", "", "104", "1", "2", "135", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "", "", "0005", "", "", "", "", "", "", "", "", "86.9", "92.7", "", "", "", "", "91.6"]} -{"pcdb_id": 10436, "brand_name": "Ferroli", "model_name": "Domicompact", "model_qualifier": "F 30 B LPG", "winter_efficiency_pct": 87.2, "summer_efficiency_pct": 78.6, "comparative_hot_water_efficiency_pct": 55.3, "output_kw_max": 30.0, "final_year_of_manufacture": 2017, "raw": ["010436", "000097", "0", "2017/Aug/21 13:43", "Ferroli SpA", "Ferroli", "Domicompact", "F 30 B LPG", "", "2005", "2017", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "30", "30", "", "", "87.2", "78.6", "", "55.3", "", "2", "1", "", "104", "1", "2", "170", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.9", "94.8", "", "", "", "", "93.7"]} -{"pcdb_id": 10437, "brand_name": "Ferroli", "model_name": "Domicompact", "model_qualifier": "F 24 B LPG", "winter_efficiency_pct": 87.2, "summer_efficiency_pct": 78.6, "comparative_hot_water_efficiency_pct": 55.3, "output_kw_max": 24.1, "final_year_of_manufacture": 2017, "raw": ["010437", "000097", "0", "2017/Aug/21 13:46", "Ferroli SpA", "Ferroli", "Domicompact", "F 24 B LPG", "", "2005", "2017", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24.1", "24.1", "", "", "87.2", "78.6", "", "55.3", "", "2", "1", "", "104", "1", "2", "135", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.9", "94.8", "", "", "", "", "93.7"]} -{"pcdb_id": 10438, "brand_name": "Ferroli", "model_name": "F 30 B LPG", "model_qualifier": "", "winter_efficiency_pct": 87.2, "summer_efficiency_pct": 78.6, "comparative_hot_water_efficiency_pct": 55.3, "output_kw_max": 30.0, "final_year_of_manufacture": 2008, "raw": ["010438", "000097", "0", "2009/Apr/28 16:09", "Ferroli SpA", "Ferroli", "F 30 B LPG", "", "", "2005", "2008", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "30.0", "30.0", "", "", "87.2", "78.6", "", "55.3", "", "2", "1", "", "104", "1", "2", "135", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "", "", "0005", "", "", "", "", "", "", "", "", "88.9", "94.8", "", "", "", "", "93.7"]} -{"pcdb_id": 10439, "brand_name": "Ferroli", "model_name": "F 24 B LPG", "model_qualifier": "", "winter_efficiency_pct": 87.2, "summer_efficiency_pct": 78.6, "comparative_hot_water_efficiency_pct": 55.3, "output_kw_max": 24.1, "final_year_of_manufacture": 2008, "raw": ["010439", "000097", "0", "2009/Apr/28 16:11", "Ferroli SpA", "Ferroli", "F 24 B LPG", "", "", "2005", "2008", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24.1", "24.1", "", "", "87.2", "78.6", "", "55.3", "", "2", "1", "", "104", "1", "2", "135", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "", "", "0005", "", "", "", "", "", "", "", "", "88.9", "94.8", "", "", "", "", "93.7"]} -{"pcdb_id": 10440, "brand_name": "Radiant", "model_name": "B-Condense", "model_qualifier": "RHA 28/100", "winter_efficiency_pct": 85.2, "summer_efficiency_pct": 78.5, "comparative_hot_water_efficiency_pct": 35.4, "output_kw_max": 27.47, "final_year_of_manufacture": 2007, "raw": ["010440", "000088", "0", "2024/Jan/31 10:17", "Radiant Bruciatori SpA", "Radiant", "B-Condense", "RHA 28/100", "", "2005", "2007", "1", "1", "1", "2", "0", "", "", "2", "2", "2", "27.47", "27.47", "", "", "85.2", "78.5", "", "35.4", "", "2", "", "", "106", "1", "2", "165", "", "2", "2", "0", "105", "0", "15", "2", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "85.8", "90.8", "", "", "", "", "89.9"]} -{"pcdb_id": 10441, "brand_name": "Radiant", "model_name": "B-Condense", "model_qualifier": "RHA 28", "winter_efficiency_pct": 85.2, "summer_efficiency_pct": 78.0, "comparative_hot_water_efficiency_pct": 45.3, "output_kw_max": 27.47, "final_year_of_manufacture": 2007, "raw": ["010441", "000088", "0", "2024/Jan/31 10:17", "Radiant Bruciatori SpA", "Radiant", "B-Condense", "RHA 28", "", "2005", "2007", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "27.47", "27.47", "", "", "85.2", "78.0", "", "45.3", "", "2", "", "", "106", "1", "2", "165", "", "2", "2", "0", "18.3", "0", "15", "2", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "85.8", "90.8", "", "", "", "", "89.9"]} -{"pcdb_id": 10442, "brand_name": "Ideal", "model_name": "icos System", "model_qualifier": "HE 15", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 14.6, "final_year_of_manufacture": 2001, "raw": ["010442", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "icos System", "HE 15", "41 421 99", "2005", "2001", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "14.6", "14.6", "", "", "89.0", "80.0", "", "58.4", "", "2", "", "", "102", "1", "2", "38", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.5", "99.0", "", "", "", "", "97.0"]} -{"pcdb_id": 10443, "brand_name": "Main", "model_name": "Combi", "model_qualifier": "24", "winter_efficiency_pct": 79.5, "summer_efficiency_pct": 69.4, "comparative_hot_water_efficiency_pct": 48.8, "output_kw_max": 24.0, "final_year_of_manufacture": null, "raw": ["010443", "000005", "0", "2006/Jan/17 12:31", "Baxi Potterton", "Main", "Combi", "24", "GC No. 47-474-01", "2005", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "24", "24", "", "", "79.5", "69.4", "", "48.8", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.2", "79.2", "", "", "", "", "79.8"]} -{"pcdb_id": 10444, "brand_name": "Main", "model_name": "Combi", "model_qualifier": "24 HE", "winter_efficiency_pct": 85.8, "summer_efficiency_pct": 77.2, "comparative_hot_water_efficiency_pct": 54.3, "output_kw_max": 24.0, "final_year_of_manufacture": 2012, "raw": ["010444", "000005", "0", "2013/May/07 10:29", "Baxi Potterton", "Main", "Combi", "24 HE", "GC No. 47-474-02", "2005", "2012", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "85.8", "77.2", "", "54.3", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.2", "91.5", "", "", "", "", "90.7"]} -{"pcdb_id": 10445, "brand_name": "Potterton", "model_name": "Gold", "model_qualifier": "24 HE", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 55.8, "output_kw_max": 24.0, "final_year_of_manufacture": 2008, "raw": ["010445", "000005", "0", "2010/Nov/19 09:18", "Baxi Potterton", "Potterton", "Gold", "24 HE", "GC No. 47-590-05", "2005", "2008", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "88.0", "79.4", "", "55.8", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "96.9", "", "", "", "", "95.2"]} -{"pcdb_id": 10446, "brand_name": "Baxi", "model_name": "Platinum", "model_qualifier": "24 HE", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 55.8, "output_kw_max": 24.0, "final_year_of_manufacture": 2007, "raw": ["010446", "000005", "0", "2010/Nov/19 09:02", "Baxi Potterton", "Baxi", "Platinum", "24 HE", "GC No. 47-075-20", "2005", "2007", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "88.0", "79.4", "", "55.8", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "96.9", "", "", "", "", "95.2"]} -{"pcdb_id": 10447, "brand_name": "Glow-worm", "model_name": "Xtramax HE", "model_qualifier": "", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 81.9, "comparative_hot_water_efficiency_pct": 44.0, "output_kw_max": 28.0, "final_year_of_manufacture": null, "raw": ["010447", "000207", "0", "2024/Jan/31 10:17", "Vaillant Group", "Glow-worm", "Xtramax HE", "", "", "2005", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "28", "28", "", "", "89.2", "81.9", "", "44.0", "", "2", "1", "", "106", "1", "2", "241", "8", "2", "1", "0", "42", "0", "15", "2", "50", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.1", "99.4", "", "", "", "", "97.6"]} -{"pcdb_id": 10448, "brand_name": "Glow-worm", "model_name": "Xtramax HE", "model_qualifier": "", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 80.9, "comparative_hot_water_efficiency_pct": 43.5, "output_kw_max": 28.0, "final_year_of_manufacture": 2013, "raw": ["010448", "000207", "0", "2024/Jan/31 10:17", "Vaillant Group", "Glow-worm", "Xtramax HE", "", "GC 47-047-29", "2005", "2013", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28", "28", "", "", "88.2", "80.9", "", "43.5", "", "2", "", "", "106", "1", "2", "241", "8", "2", "1", "0", "42", "0", "15", "2", "50", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.1", "97.2", "", "", "", "", "95.5"]} -{"pcdb_id": 10449, "brand_name": "Saunier Duval", "model_name": "SD Isotwin Condens F35 E", "model_qualifier": "", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 81.9, "comparative_hot_water_efficiency_pct": 44.0, "output_kw_max": 28.0, "final_year_of_manufacture": null, "raw": ["010449", "000206", "0", "2024/Jan/31 10:17", "Vaillant Group", "Saunier Duval", "SD Isotwin Condens F35 E", "", "", "2005", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "28", "28", "", "", "89.2", "81.9", "", "44.0", "", "2", "1", "", "106", "1", "2", "241", "8", "2", "1", "0", "42", "0", "15", "2", "50", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.1", "99.4", "", "", "", "", "97.6"]} -{"pcdb_id": 10450, "brand_name": "Saunier Duval", "model_name": "SD Isotwin Condens F35 E", "model_qualifier": "", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 80.9, "comparative_hot_water_efficiency_pct": 43.5, "output_kw_max": 28.0, "final_year_of_manufacture": null, "raw": ["010450", "000206", "0", "2024/Jan/31 10:17", "Vaillant Group", "Saunier Duval", "SD Isotwin Condens F35 E", "", "GC 47-920-47", "2005", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28", "28", "", "", "88.2", "80.9", "", "43.5", "", "2", "", "", "106", "1", "2", "241", "8", "2", "1", "0", "42", "0", "15", "2", "50", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.1", "97.2", "", "", "", "", "95.5"]} -{"pcdb_id": 10451, "brand_name": "British Gas", "model_name": "537/I", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 56.4, "output_kw_max": 30.0, "final_year_of_manufacture": null, "raw": ["010451", "000035", "0", "2006/Jan/17 12:31", "Worcester Bosch Group", "British Gas", "537/I", "", "47-406-04", "2005", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "30.0", "30.0", "", "", "88.8", "80.2", "", "56.4", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.1", "98.8", "", "", "", "", "96.8"]} -{"pcdb_id": 10452, "brand_name": "British Gas", "model_name": "537/I", "model_qualifier": "", "winter_efficiency_pct": 89.8, "summer_efficiency_pct": 81.2, "comparative_hot_water_efficiency_pct": 57.1, "output_kw_max": 30.0, "final_year_of_manufacture": null, "raw": ["010452", "000035", "0", "2006/Jan/17 12:31", "Worcester Bosch Group", "British Gas", "537/I", "", "47-406-05", "2005", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "30.0", "30.0", "", "", "89.8", "81.2", "", "57.1", "", "2", "1", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.1", "101.0", "", "", "", "", "99.0"]} -{"pcdb_id": 10453, "brand_name": "British Gas", "model_name": "542/I", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 56.4, "output_kw_max": 30.0, "final_year_of_manufacture": null, "raw": ["010453", "000035", "0", "2006/Jan/17 12:31", "Worcester Bosch Group", "British Gas", "542/I", "", "47-406-06", "2005", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "30.0", "30.0", "", "", "88.8", "80.2", "", "56.4", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.1", "98.8", "", "", "", "", "96.8"]} -{"pcdb_id": 10454, "brand_name": "British Gas", "model_name": "542/I", "model_qualifier": "", "winter_efficiency_pct": 89.8, "summer_efficiency_pct": 81.2, "comparative_hot_water_efficiency_pct": 57.1, "output_kw_max": 30.0, "final_year_of_manufacture": null, "raw": ["010454", "000035", "0", "2006/Jan/17 12:31", "Worcester Bosch Group", "British Gas", "542/I", "", "47-406-07", "2005", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "30.0", "30.0", "", "", "89.8", "81.2", "", "57.1", "", "2", "1", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.1", "101.0", "", "", "", "", "99.0"]} -{"pcdb_id": 10455, "brand_name": "British Gas", "model_name": "430/I", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 30.0, "final_year_of_manufacture": null, "raw": ["010455", "000035", "0", "2012/Mar/27 10:12", "Worcester Bosch Group", "British Gas", "430/I", "", "41-311-80", "2005", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "30.0", "30.0", "", "", "88.8", "79.8", "", "58.3", "", "2", "", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.1", "98.8", "", "", "", "", "96.8"]} -{"pcdb_id": 10456, "brand_name": "British Gas", "model_name": "430/I", "model_qualifier": "", "winter_efficiency_pct": 89.8, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 59.1, "output_kw_max": 30.0, "final_year_of_manufacture": null, "raw": ["010456", "000035", "0", "2012/Mar/27 10:12", "Worcester Bosch Group", "British Gas", "430/I", "", "41-311-81", "2005", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "30.0", "30.0", "", "", "89.8", "80.8", "", "59.1", "", "2", "1", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.1", "101.0", "", "", "", "", "99.0"]} -{"pcdb_id": 10457, "brand_name": "British Gas", "model_name": "532/I", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 56.4, "output_kw_max": 30.0, "final_year_of_manufacture": null, "raw": ["010457", "000035", "0", "2006/Jan/17 12:31", "Worcester Bosch Group", "British Gas", "532/I", "", "47-406-02", "2005", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "30.0", "30.0", "", "", "88.8", "80.2", "", "56.4", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.1", "98.8", "", "", "", "", "96.8"]} -{"pcdb_id": 10458, "brand_name": "British Gas", "model_name": "532/I", "model_qualifier": "", "winter_efficiency_pct": 89.8, "summer_efficiency_pct": 81.2, "comparative_hot_water_efficiency_pct": 57.1, "output_kw_max": 30.0, "final_year_of_manufacture": null, "raw": ["010458", "000035", "0", "2006/Jan/17 12:31", "Worcester Bosch Group", "British Gas", "532/I", "", "47-406-03", "2005", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "30.0", "30.0", "", "", "89.8", "81.2", "", "57.1", "", "2", "1", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.1", "101.0", "", "", "", "", "99.0"]} -{"pcdb_id": 10459, "brand_name": "Worcester", "model_name": "Greenstar Cdi", "model_qualifier": "30 Cdi System", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 30.0, "final_year_of_manufacture": 2014, "raw": ["010459", "000035", "0", "2020/Sep/08 09:25", "Worcester Bosch Group", "Worcester", "Greenstar Cdi", "30 Cdi System", "41-311-93", "2005", "2014", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "30.0", "30.0", "", "", "88.8", "79.8", "", "58.3", "", "2", "", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.1", "98.8", "", "", "", "", "96.8"]} -{"pcdb_id": 10460, "brand_name": "Worcester", "model_name": "Greenstar Cdi", "model_qualifier": "30 Cdi System", "winter_efficiency_pct": 89.8, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 59.1, "output_kw_max": 30.0, "final_year_of_manufacture": 2014, "raw": ["010460", "000035", "0", "2020/Sep/08 09:25", "Worcester Bosch Group", "Worcester", "Greenstar Cdi", "30 Cdi System", "41-311-97", "2005", "2014", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "30.0", "30.0", "", "", "89.8", "80.8", "", "59.1", "", "2", "1", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.1", "101.0", "", "", "", "", "99.0"]} -{"pcdb_id": 10461, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "18Ri", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 18.0, "final_year_of_manufacture": 2015, "raw": ["010461", "000035", "0", "2020/Sep/08 09:25", "Worcester Bosch Group", "Worcester", "Greenstar", "18Ri", "41-311-78", "2005", "2015", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "18.00", "18.00", "", "", "89.1", "80.1", "", "58.5", "", "2", "1", "", "102", "1", "2", "50", "5", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.7", "99.2", "", "", "", "", "97.4"]} -{"pcdb_id": 10462, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "18Ri", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 18.0, "final_year_of_manufacture": 2015, "raw": ["010462", "000035", "0", "2020/Sep/08 09:25", "Worcester Bosch Group", "Worcester", "Greenstar", "18Ri", "41-311-77", "2005", "2015", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18.00", "18.00", "", "", "88.1", "79.1", "", "57.7", "", "2", "", "", "102", "1", "2", "50", "5", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "97.0", "", "", "", "", "95.3"]} -{"pcdb_id": 10463, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "15Ri", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 15.0, "final_year_of_manufacture": 2015, "raw": ["010463", "000035", "0", "2020/Sep/08 09:25", "Worcester Bosch Group", "Worcester", "Greenstar", "15Ri", "41-311-76", "2005", "2015", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "15.00", "15.00", "", "", "89.1", "80.1", "", "58.5", "", "2", "1", "", "102", "1", "2", "50", "5", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.7", "99.2", "", "", "", "", "97.4"]} -{"pcdb_id": 10464, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "15Ri", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 15.0, "final_year_of_manufacture": 2015, "raw": ["010464", "000035", "0", "2020/Sep/08 09:25", "Worcester Bosch Group", "Worcester", "Greenstar", "15Ri", "41-311-75", "2005", "2015", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "15.00", "15.00", "", "", "88.1", "79.1", "", "57.7", "", "2", "", "", "102", "1", "2", "50", "5", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "97.0", "", "", "", "", "95.3"]} -{"pcdb_id": 10465, "brand_name": "ACV", "model_name": "HeatMaster 35TC", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 81.4, "comparative_hot_water_efficiency_pct": 39.3, "output_kw_max": 34.1, "final_year_of_manufacture": null, "raw": ["010465", "000243", "0", "2024/Jan/31 10:17", "ACV International", "ACV", "HeatMaster 35TC", "", "05620001", "2005", "current", "1", "1", "1", "2", "0", "", "", "2", "2", "2", "34.1", "34.1", "", "", "88.4", "81.4", "", "39.3", "", "2", "", "", "106", "1", "2", "300", "", "1", "2", "0", "189", "0", "50", "2", "80", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.2", "97.8", "", "", "", "", "95.9"]} -{"pcdb_id": 10466, "brand_name": "ACV", "model_name": "Prestige 32 Excellence", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 81.3, "comparative_hot_water_efficiency_pct": 40.4, "output_kw_max": 31.0, "final_year_of_manufacture": null, "raw": ["010466", "000243", "0", "2024/Jan/31 10:17", "ACV International", "ACV", "Prestige 32 Excellence", "", "05617601", "2003", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "31.0", "31.0", "", "", "88.6", "81.3", "", "40.4", "", "2", "", "", "106", "1", "2", "300", "", "2", "1", "0", "70", "0", "15", "2", "80", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.2", "98.2", "", "", "", "", "96.3"]} -{"pcdb_id": 10467, "brand_name": "ACV", "model_name": "Prestige 24 Excellence", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 81.3, "comparative_hot_water_efficiency_pct": 40.4, "output_kw_max": 23.4, "final_year_of_manufacture": null, "raw": ["010467", "000243", "0", "2024/Jan/31 10:17", "ACV International", "ACV", "Prestige 24 Excellence", "", "05617501", "2003", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "23.4", "23.4", "", "", "88.6", "81.3", "", "40.4", "", "2", "", "", "106", "1", "2", "300", "", "2", "1", "0", "70", "0", "15", "2", "80", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.2", "98.2", "", "", "", "", "96.3"]} -{"pcdb_id": 10468, "brand_name": "ACV", "model_name": "Prestige 75 Solo", "model_qualifier": "", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 69.9, "final_year_of_manufacture": null, "raw": ["010468", "000243", "0", "2012/Mar/27 10:12", "ACV International", "ACV", "Prestige 75 Solo", "", "05619601", "2005", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "69.9", "69.9", "", "", "88.2", "79.2", "", "57.8", "", "2", "", "", "102", "1", "2", "200", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.2", "97.1", "", "", "", "", "95.4"]} -{"pcdb_id": 10469, "brand_name": "ACV", "model_name": "Prestige 50 Solo", "model_qualifier": "", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 48.4, "final_year_of_manufacture": null, "raw": ["010469", "000243", "0", "2012/Mar/27 10:12", "ACV International", "ACV", "Prestige 50 Solo", "", "05610501", "2005", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "48.4", "48.4", "", "", "88.2", "79.2", "", "57.8", "", "2", "", "", "102", "1", "2", "200", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.2", "97.1", "", "", "", "", "95.4"]} -{"pcdb_id": 10470, "brand_name": "ACV", "model_name": "Prestige 32 Solo", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 31.0, "final_year_of_manufacture": null, "raw": ["010470", "000243", "0", "2012/Mar/27 10:12", "ACV International", "ACV", "Prestige 32 Solo", "", "05605601", "2003", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "31.0", "31.0", "", "", "88.6", "79.6", "", "58.1", "", "2", "", "", "102", "1", "2", "200", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.2", "98.2", "", "", "", "", "96.3"]} -{"pcdb_id": 10471, "brand_name": "ACV", "model_name": "Prestige 24 Solo", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 23.4, "final_year_of_manufacture": null, "raw": ["010471", "000243", "0", "2012/Mar/27 10:12", "ACV International", "ACV", "Prestige 24 Solo", "", "05605501", "2003", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "23.4", "23.4", "", "", "88.6", "79.6", "", "58.1", "", "2", "", "", "102", "1", "2", "200", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.2", "98.2", "", "", "", "", "96.3"]} -{"pcdb_id": 10472, "brand_name": "British Gas", "model_name": "537", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 56.4, "output_kw_max": 30.0, "final_year_of_manufacture": null, "raw": ["010472", "000035", "0", "2006/Jan/17 12:31", "Worcester Bosch Group", "British Gas", "537", "", "", "2005", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "30.0", "30.0", "", "", "88.8", "80.2", "", "56.4", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.1", "98.8", "", "", "", "", "96.8"]} -{"pcdb_id": 10473, "brand_name": "British Gas", "model_name": "537 LPG", "model_qualifier": "", "winter_efficiency_pct": 89.8, "summer_efficiency_pct": 81.2, "comparative_hot_water_efficiency_pct": 57.1, "output_kw_max": 30.0, "final_year_of_manufacture": null, "raw": ["010473", "000035", "0", "2006/Jan/17 12:31", "Worcester Bosch Group", "British Gas", "537 LPG", "", "", "2005", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "30.0", "30.0", "", "", "89.8", "81.2", "", "57.1", "", "2", "1", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.1", "101.0", "", "", "", "", "99.0"]} -{"pcdb_id": 10474, "brand_name": "British Gas", "model_name": "542", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 56.4, "output_kw_max": 30.0, "final_year_of_manufacture": null, "raw": ["010474", "000035", "0", "2005/Oct/30 20:07", "Worcester Bosch Group", "British Gas", "542", "", "", "2005", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "30", "30", "", "", "88.8", "80.2", "", "56.4", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.1", "98.8", "", "", "", "", "96.8"]} -{"pcdb_id": 10475, "brand_name": "British Gas", "model_name": "542 LPG", "model_qualifier": "", "winter_efficiency_pct": 89.8, "summer_efficiency_pct": 81.2, "comparative_hot_water_efficiency_pct": 57.1, "output_kw_max": 30.0, "final_year_of_manufacture": null, "raw": ["010475", "000035", "0", "2005/Oct/30 20:12", "Worcester Bosch Group", "British Gas", "542 LPG", "", "", "2005", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "30", "30", "", "", "89.8", "81.2", "", "57.1", "", "2", "1", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.1", "101.0", "", "", "", "", "99.0"]} -{"pcdb_id": 10476, "brand_name": "British Gas", "model_name": "532", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 56.4, "output_kw_max": 30.0, "final_year_of_manufacture": null, "raw": ["010476", "000035", "0", "2005/Oct/30 20:07", "Worcester Bosch Group", "British Gas", "532", "", "", "2005", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "30", "30", "", "", "88.8", "80.2", "", "56.4", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.1", "98.8", "", "", "", "", "96.8"]} -{"pcdb_id": 10477, "brand_name": "British Gas", "model_name": "532 LPG", "model_qualifier": "", "winter_efficiency_pct": 89.8, "summer_efficiency_pct": 81.2, "comparative_hot_water_efficiency_pct": 57.1, "output_kw_max": 30.0, "final_year_of_manufacture": null, "raw": ["010477", "000035", "0", "2005/Oct/30 20:11", "Worcester Bosch Group", "British Gas", "532 LPG", "", "", "2005", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "30", "30", "", "", "89.8", "81.2", "", "57.1", "", "2", "1", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.1", "101.0", "", "", "", "", "99.0"]} -{"pcdb_id": 10478, "brand_name": "British Gas", "model_name": "430", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 30.0, "final_year_of_manufacture": null, "raw": ["010478", "000035", "0", "2012/Mar/27 10:12", "Worcester Bosch Group", "British Gas", "430", "", "", "2005", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "30", "30", "", "", "88.8", "79.8", "", "58.3", "", "2", "", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.1", "98.8", "", "", "", "", "96.8"]} -{"pcdb_id": 10479, "brand_name": "British Gas", "model_name": "430 LPG", "model_qualifier": "", "winter_efficiency_pct": 89.8, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 59.1, "output_kw_max": 30.0, "final_year_of_manufacture": null, "raw": ["010479", "000035", "0", "2012/Mar/27 10:12", "Worcester Bosch Group", "British Gas", "430 LPG", "", "", "2005", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "30", "30", "", "", "89.8", "80.8", "", "59.1", "", "2", "1", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.1", "101.0", "", "", "", "", "99.0"]} -{"pcdb_id": 10480, "brand_name": "Wolf", "model_name": "CGB-50", "model_qualifier": "", "winter_efficiency_pct": 89.5, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 58.8, "output_kw_max": 49.9, "final_year_of_manufacture": null, "raw": ["010480", "000240", "0", "2012/Mar/27 10:12", "Wolf", "Wolf", "CGB-50", "", "8611570", "2005", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "49.9", "49.9", "", "", "89.5", "80.5", "", "58.8", "", "2", "1", "", "102", "1", "2", "84", "6", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.2", "100.1", "", "", "", "", "98.2"]} -{"pcdb_id": 10481, "brand_name": "Wolf", "model_name": "CGB-50", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 49.9, "final_year_of_manufacture": null, "raw": ["010481", "000240", "0", "2012/Mar/27 10:12", "Wolf", "Wolf", "CGB-50", "", "8611568", "2005", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "49.9", "49.9", "", "", "88.5", "79.5", "", "58.1", "", "2", "", "", "102", "1", "2", "84", "6", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.2", "97.9", "", "", "", "", "96.1"]} -{"pcdb_id": 10482, "brand_name": "Wolf", "model_name": "CGB-35", "model_qualifier": "", "winter_efficiency_pct": 89.6, "summer_efficiency_pct": 80.6, "comparative_hot_water_efficiency_pct": 58.9, "output_kw_max": 34.9, "final_year_of_manufacture": null, "raw": ["010482", "000240", "0", "2012/Mar/27 10:12", "Wolf", "Wolf", "CGB-35", "", "8611569", "2005", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "34.9", "34.9", "", "", "89.6", "80.6", "", "58.9", "", "2", "1", "", "102", "1", "2", "54", "6", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.3", "100.3", "", "", "", "", "98.4"]} -{"pcdb_id": 10483, "brand_name": "Wolf", "model_name": "CGB-35", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 34.9, "final_year_of_manufacture": null, "raw": ["010483", "000240", "0", "2012/Mar/27 10:12", "Wolf", "Wolf", "CGB-35", "", "8611567", "2005", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "34.9", "34.9", "", "", "88.6", "79.6", "", "58.1", "", "2", "", "", "102", "1", "2", "54", "6", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "98.1", "", "", "", "", "96.3"]} -{"pcdb_id": 10484, "brand_name": "Trianco", "model_name": "Eurotrader Premier 100/125", "model_qualifier": "", "winter_efficiency_pct": 87.4, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 36.6, "final_year_of_manufacture": null, "raw": ["010484", "000062", "0", "2012/Mar/27 10:12", "Trianco", "Trianco", "Eurotrader Premier 100/125", "", "", "2005", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "36.6", "36.6", "", "", "87.4", "79.6", "", "58.1", "", "2", "", "", "201", "1", "1", "148", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "89.5", "93.7", "", "", "", "", "92.9"]} -{"pcdb_id": 10485, "brand_name": "Trianco", "model_name": "Eurotrader Premier 50/90", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 26.4, "final_year_of_manufacture": null, "raw": ["010485", "000062", "0", "2012/Mar/27 10:12", "Trianco", "Trianco", "Eurotrader Premier 50/90", "", "", "2005", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "26.4", "26.4", "", "", "88.0", "80.2", "", "58.6", "", "2", "", "", "201", "1", "1", "148", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.0", "95.1", "", "", "", "", "94.1"]} -{"pcdb_id": 10486, "brand_name": "Trianco", "model_name": "Eurostar Premier External 50/90", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 26.4, "final_year_of_manufacture": null, "raw": ["010486", "000062", "0", "2012/Mar/27 10:12", "Trianco", "Trianco", "Eurostar Premier External 50/90", "", "", "2005", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "26.4", "26.4", "", "", "88.0", "80.2", "", "58.6", "", "2", "", "", "201", "1", "1", "148", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.0", "95.1", "", "", "", "", "94.1"]} -{"pcdb_id": 10487, "brand_name": "Trianco", "model_name": "Eurostar Premier External 100/125", "model_qualifier": "", "winter_efficiency_pct": 87.4, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 36.6, "final_year_of_manufacture": null, "raw": ["010487", "000062", "0", "2012/Mar/27 10:12", "Trianco", "Trianco", "Eurostar Premier External 100/125", "", "", "2005", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "36.6", "36.6", "", "", "87.4", "79.6", "", "58.1", "", "2", "", "", "201", "1", "1", "148", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "89.5", "93.7", "", "", "", "", "92.9"]} -{"pcdb_id": 10488, "brand_name": "Trianco", "model_name": "Eurostar Premier Kitchen 100/125", "model_qualifier": "", "winter_efficiency_pct": 87.4, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 36.6, "final_year_of_manufacture": null, "raw": ["010488", "000062", "0", "2012/Mar/27 10:12", "Trianco", "Trianco", "Eurostar Premier Kitchen 100/125", "", "", "2005", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "36.6", "36.6", "", "", "87.4", "79.6", "", "58.1", "", "2", "", "", "201", "1", "1", "148", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "89.5", "93.7", "", "", "", "", "92.9"]} -{"pcdb_id": 10489, "brand_name": "Trianco", "model_name": "Contractor 50/70 WM", "model_qualifier": "", "winter_efficiency_pct": 85.6, "summer_efficiency_pct": 73.9, "comparative_hot_water_efficiency_pct": 54.0, "output_kw_max": 17.6, "final_year_of_manufacture": null, "raw": ["010489", "000062", "0", "2012/Mar/27 10:12", "Trianco", "Trianco", "Contractor 50/70 WM", "", "", "2005", "current", "4", "2", "1", "1", "0", "", "", "1", "2", "2", "17.6", "17.6", "", "", "85.6", "73.9", "", "54.0", "", "2", "", "", "201", "1", "1", "70", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.4", "85.9", "", "", "", "", "85.8"]} -{"pcdb_id": 10490, "brand_name": "ACV", "model_name": "Prestige 24 Excellence P", "model_qualifier": "", "winter_efficiency_pct": 89.6, "summer_efficiency_pct": 82.3, "comparative_hot_water_efficiency_pct": 40.9, "output_kw_max": 23.4, "final_year_of_manufacture": null, "raw": ["010490", "000243", "0", "2024/Jan/31 10:17", "ACV International", "ACV", "Prestige 24 Excellence P", "", "03617501", "2003", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "23.4", "23.4", "", "", "89.6", "82.3", "", "40.9", "", "2", "1", "", "106", "1", "2", "300", "", "2", "1", "0", "70", "0", "15", "2", "80", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.2", "100.4", "", "", "", "", "98.4"]} -{"pcdb_id": 10491, "brand_name": "ACV", "model_name": "Prestige 24 Solo P", "model_qualifier": "", "winter_efficiency_pct": 89.6, "summer_efficiency_pct": 80.6, "comparative_hot_water_efficiency_pct": 58.9, "output_kw_max": 23.4, "final_year_of_manufacture": null, "raw": ["010491", "000243", "0", "2012/Mar/27 10:12", "ACV International", "ACV", "Prestige 24 Solo P", "", "03605501", "2003", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "23.4", "23.4", "", "", "89.6", "80.6", "", "58.9", "", "2", "1", "", "102", "1", "2", "200", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.2", "100.4", "", "", "", "", "98.4"]} -{"pcdb_id": 10492, "brand_name": "ACV", "model_name": "Prestige 32 Excellence P", "model_qualifier": "", "winter_efficiency_pct": 89.6, "summer_efficiency_pct": 82.3, "comparative_hot_water_efficiency_pct": 40.9, "output_kw_max": 29.6, "final_year_of_manufacture": null, "raw": ["010492", "000243", "0", "2024/Jan/31 10:17", "ACV International", "ACV", "Prestige 32 Excellence P", "", "03617601", "2003", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "29.6", "29.6", "", "", "89.6", "82.3", "", "40.9", "", "2", "1", "", "106", "1", "2", "300", "", "2", "1", "0", "70", "0", "15", "2", "80", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.2", "100.4", "", "", "", "", "98.4"]} -{"pcdb_id": 10493, "brand_name": "ACV", "model_name": "Prestige 32 Solo P", "model_qualifier": "", "winter_efficiency_pct": 89.6, "summer_efficiency_pct": 80.6, "comparative_hot_water_efficiency_pct": 58.9, "output_kw_max": 29.6, "final_year_of_manufacture": null, "raw": ["010493", "000243", "0", "2012/Mar/27 10:12", "ACV International", "ACV", "Prestige 32 Solo P", "", "03605601", "2003", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "29.6", "29.6", "", "", "89.6", "80.6", "", "58.9", "", "2", "1", "", "102", "1", "2", "200", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.2", "100.4", "", "", "", "", "98.4"]} -{"pcdb_id": 10494, "brand_name": "ACV", "model_name": "Prestige 50 Solo P", "model_qualifier": "", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 48.4, "final_year_of_manufacture": null, "raw": ["010494", "000243", "0", "2012/Mar/27 10:12", "ACV International", "ACV", "Prestige 50 Solo P", "", "03610501", "2005", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "48.4", "48.4", "", "", "89.2", "80.2", "", "58.6", "", "2", "1", "", "102", "1", "2", "200", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.2", "99.3", "", "", "", "", "97.6"]} -{"pcdb_id": 10495, "brand_name": "ACV", "model_name": "Prestige 75 Solo P", "model_qualifier": "", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 69.9, "final_year_of_manufacture": null, "raw": ["010495", "000243", "0", "2012/Mar/27 10:12", "ACV International", "ACV", "Prestige 75 Solo P", "", "03605601", "2005", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "69.9", "69.9", "", "", "89.2", "80.2", "", "58.6", "", "2", "1", "", "102", "1", "2", "200", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.2", "99.3", "", "", "", "", "97.6"]} -{"pcdb_id": 10496, "brand_name": "ACV", "model_name": "HeatMaster 35TC P", "model_qualifier": "", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 82.4, "comparative_hot_water_efficiency_pct": 39.8, "output_kw_max": 29.9, "final_year_of_manufacture": null, "raw": ["010496", "000243", "0", "2024/Jan/31 10:17", "ACV International", "ACV", "HeatMaster 35TC P", "", "03620001", "2005", "current", "2", "1", "1", "2", "0", "", "", "2", "2", "2", "29.9", "29.9", "", "", "89.4", "82.4", "", "39.8", "", "2", "1", "", "106", "1", "2", "300", "", "1", "2", "0", "189", "0", "50", "2", "80", "97", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.2", "99.9", "", "", "", "", "98.1"]} -{"pcdb_id": 10498, "brand_name": "Worcester", "model_name": "Greenstar Danesmoor", "model_qualifier": "18/25-OOO-GB", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 25.0, "final_year_of_manufacture": 2013, "raw": ["010498", "000035", "0", "2020/Sep/08 09:26", "Worcester Bosch Group", "Worcester", "Greenstar Danesmoor", "18/25-OOO-GB", "", "2005", "2013", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "18", "25", "", "", "88.0", "80.2", "", "58.6", "", "2", "", "", "201", "1", "1", "155", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.0", "94.7", "", "", "", "", "94.0"]} -{"pcdb_id": 10499, "brand_name": "Worcester", "model_name": "Greenstar Heatslave", "model_qualifier": "18/25-OSO-GB", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 81.9, "comparative_hot_water_efficiency_pct": 41.6, "output_kw_max": 25.0, "final_year_of_manufacture": 2013, "raw": ["010499", "000035", "0", "2024/Jan/31 10:17", "Worcester Bosch Group", "Worcester", "Greenstar Heatslave", "18/25-OSO-GB", "", "2005", "2013", "4", "1", "1", "2", "0", "", "", "2", "3", "2", "18", "25", "", "", "88.0", "81.9", "", "41.6", "", "2", "", "", "203", "1", "1", "240", "0", "1", "1", "0", "69", "0", "25", "3", "82", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.0", "94.7", "", "", "", "", "94.0"]} -{"pcdb_id": 10500, "brand_name": "Worcester", "model_name": "Greenstar Utility", "model_qualifier": "18/25-OOO-GB", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 25.0, "final_year_of_manufacture": 2013, "raw": ["010500", "000035", "0", "2020/Sep/08 09:26", "Worcester Bosch Group", "Worcester", "Greenstar Utility", "18/25-OOO-GB", "", "2005", "2013", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "18", "25", "", "", "88.0", "80.2", "", "58.6", "", "2", "", "", "201", "1", "1", "155", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.0", "94.7", "", "", "", "", "94.0"]} -{"pcdb_id": 10501, "brand_name": "Alpha", "model_name": "HE CB33", "model_qualifier": "", "winter_efficiency_pct": 85.3, "summer_efficiency_pct": 76.7, "comparative_hot_water_efficiency_pct": 53.9, "output_kw_max": 32.0, "final_year_of_manufacture": 2008, "raw": ["010501", "000001", "0", "2011/Sep/06 13:13", "Alpha Therm", "Alpha", "HE CB33", "", "", "2005", "2008", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "32", "32", "", "", "85.3", "76.7", "", "53.9", "", "2", "", "", "104", "1", "2", "170", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.5", "90.1", "", "", "", "", "89.6"]} -{"pcdb_id": 10502, "brand_name": "Alpha", "model_name": "HE CB25", "model_qualifier": "", "winter_efficiency_pct": 85.3, "summer_efficiency_pct": 76.7, "comparative_hot_water_efficiency_pct": 53.9, "output_kw_max": 24.0, "final_year_of_manufacture": 2008, "raw": ["010502", "000001", "0", "2011/Sep/06 13:13", "Alpha Therm", "Alpha", "HE CB25", "", "", "2005", "2008", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "85.3", "76.7", "", "53.9", "", "2", "", "", "104", "1", "2", "150", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.5", "90.1", "", "", "", "", "89.6"]} -{"pcdb_id": 10503, "brand_name": "Alpha", "model_name": "HE SY25", "model_qualifier": "", "winter_efficiency_pct": 85.3, "summer_efficiency_pct": 76.3, "comparative_hot_water_efficiency_pct": 55.7, "output_kw_max": 24.0, "final_year_of_manufacture": 2007, "raw": ["010503", "000001", "0", "2012/Mar/27 10:12", "Alpha Therm", "Alpha", "HE SY25", "", "", "2005", "2007", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24", "24", "", "", "85.3", "76.3", "", "55.7", "", "2", "", "", "102", "1", "2", "150", "2", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.5", "90.1", "", "", "", "", "89.6"]} -{"pcdb_id": 10504, "brand_name": "Alpha", "model_name": "CD18R", "model_qualifier": "", "winter_efficiency_pct": 87.7, "summer_efficiency_pct": 78.7, "comparative_hot_water_efficiency_pct": 57.5, "output_kw_max": 18.0, "final_year_of_manufacture": null, "raw": ["010504", "000001", "0", "2012/Mar/27 10:12", "Alpha Therm", "Alpha", "CD18R", "", "", "2005", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18", "18", "", "", "87.7", "78.7", "", "57.5", "", "2", "", "", "102", "1", "2", "55", "2", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "96.0", "", "", "", "", "94.5"]} -{"pcdb_id": 10506, "brand_name": "ICI Caldaie", "model_name": "Solar C25", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 56.2, "output_kw_max": 24.4, "final_year_of_manufacture": null, "raw": ["010506", "000077", "0", "2005/Aug/31 10:32", "ICI Caldaie SPA", "ICI Caldaie", "Solar C25", "", "", "2005", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.4", "24.4", "", "", "88.5", "79.9", "", "56.2", "", "2", "", "", "104", "1", "2", "150", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "97.9", "", "", "", "", "96.1"]} -{"pcdb_id": 10507, "brand_name": "ICI Caldaie", "model_name": "Solar C31", "model_qualifier": "", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 56.0, "output_kw_max": 30.2, "final_year_of_manufacture": null, "raw": ["010507", "000077", "0", "2005/Aug/31 10:32", "ICI Caldaie SPA", "ICI Caldaie", "Solar C31", "", "", "2005", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "30.2", "30.2", "", "", "88.2", "79.6", "", "56.0", "", "2", "", "", "104", "1", "2", "150", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "97.5", "", "", "", "", "95.7"]} -{"pcdb_id": 10508, "brand_name": "ICI Caldaie", "model_name": "Solar System C31", "model_qualifier": "", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 30.2, "final_year_of_manufacture": null, "raw": ["010508", "000077", "0", "2022/May/10 10:35", "ICI Caldaie SPA", "ICI Caldaie", "Solar System C31", "", "", "2005", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "30.2", "30.2", "", "", "88.2", "79.2", "", "57.9", "", "2", "", "", "102", "1", "2", "150", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "97.5", "", "", "", "", "95.7"]} -{"pcdb_id": 10509, "brand_name": "ICI Caldaie", "model_name": "Solar System C25", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 24.4, "final_year_of_manufacture": null, "raw": ["010509", "000077", "0", "2022/May/10 10:35", "ICI Caldaie SPA", "ICI Caldaie", "Solar System C25", "", "", "2005", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24.4", "24.4", "", "", "88.5", "79.5", "", "58.0", "", "2", "", "", "102", "1", "2", "150", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "97.9", "", "", "", "", "96.1"]} -{"pcdb_id": 10510, "brand_name": "Gledhill", "model_name": "GB30", "model_qualifier": "AGB5030", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 32.0, "final_year_of_manufacture": null, "raw": ["010510", "000072", "0", "2012/Mar/27 10:12", "Gledhill Water Storage", "Gledhill", "GB30", "AGB5030", "", "2005", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "32", "32", "", "", "88.6", "79.6", "", "58.1", "", "2", "", "", "102", "1", "2", "60", "6.5", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.2", "98.1", "", "", "", "", "96.2"]} -{"pcdb_id": 10511, "brand_name": "Gledhill", "model_name": "GB25", "model_qualifier": "AGB5025", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 27.2, "final_year_of_manufacture": null, "raw": ["010511", "000072", "0", "2012/Mar/27 10:12", "Gledhill Water Storage", "Gledhill", "GB25", "AGB5025", "", "2005", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "27.2", "27.2", "", "", "88.6", "79.6", "", "58.2", "", "2", "", "", "102", "1", "2", "60", "6.5", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.4", "98.2", "", "", "", "", "96.3"]} -{"pcdb_id": 10512, "brand_name": "Gledhill", "model_name": "GB20", "model_qualifier": "AGB5020", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 22.0, "final_year_of_manufacture": null, "raw": ["010512", "000072", "0", "2012/Mar/27 10:12", "Gledhill Water Storage", "Gledhill", "GB20", "AGB5020", "", "2005", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "22", "22", "", "", "88.2", "79.2", "", "57.9", "", "2", "", "", "102", "1", "2", "60", "6.5", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.5", "97.2", "", "", "", "", "95.6"]} -{"pcdb_id": 10513, "brand_name": "Gledhill", "model_name": "GB15", "model_qualifier": "AGB5015", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 16.4, "final_year_of_manufacture": null, "raw": ["010513", "000072", "0", "2012/Mar/27 10:12", "Gledhill Water Storage", "Gledhill", "GB15", "AGB5015", "", "2005", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "16.4", "16.4", "", "", "88.1", "79.1", "", "57.8", "", "2", "", "", "102", "1", "2", "60", "6.5", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.7", "96.9", "", "", "", "", "95.3"]} -{"pcdb_id": 10514, "brand_name": "Gledhill", "model_name": "GB10", "model_qualifier": "AGB5010", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 10.87, "final_year_of_manufacture": null, "raw": ["010514", "000072", "0", "2012/Mar/27 10:12", "Gledhill Water Storage", "Gledhill", "GB10", "AGB5010", "", "2005", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "10.87", "10.87", "", "", "88.5", "79.5", "", "58.1", "", "2", "", "", "102", "1", "2", "60", "6.5", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "98.0", "", "", "", "", "96.1"]} -{"pcdb_id": 10515, "brand_name": "Warmflow", "model_name": "Combi", "model_qualifier": "C90HE", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 81.9, "comparative_hot_water_efficiency_pct": 41.4, "output_kw_max": 26.0, "final_year_of_manufacture": null, "raw": ["010515", "000063", "0", "2024/Jan/31 10:17", "Warmflow Engineering", "Warmflow", "Combi", "C90HE", "", "2005", "current", "4", "1", "1", "2", "0", "", "", "2", "3", "2", "21", "26", "", "", "88.0", "81.9", "", "41.4", "", "2", "", "", "203", "1", "1", "250", "0", "1", "1", "0", "70", "0", "25", "6", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.8", "94.8", "", "", "", "", "94.1"]} -{"pcdb_id": 10516, "brand_name": "Warmflow", "model_name": "System", "model_qualifier": "S90HE", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 26.0, "final_year_of_manufacture": null, "raw": ["010516", "000063", "0", "2012/Mar/27 10:12", "Warmflow Engineering", "Warmflow", "System", "S90HE", "", "2005", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "21", "26", "", "", "88.0", "80.2", "", "58.6", "", "2", "", "", "201", "1", "1", "160", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.8", "94.8", "", "", "", "", "94.1"]} -{"pcdb_id": 10517, "brand_name": "Warmflow", "model_name": "System", "model_qualifier": "S70HE", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 21.0, "final_year_of_manufacture": null, "raw": ["010517", "000063", "0", "2012/Mar/27 10:12", "Warmflow Engineering", "Warmflow", "System", "S70HE", "", "2005", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "15", "21", "", "", "87.9", "80.1", "", "58.5", "", "2", "", "", "201", "1", "1", "160", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "89.5", "95.0", "", "", "", "", "94.0"]} -{"pcdb_id": 10518, "brand_name": "Warmflow", "model_name": "Utility", "model_qualifier": "U120HE", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 33.0, "final_year_of_manufacture": null, "raw": ["010518", "000063", "0", "2013/Mar/28 08:27", "Warmflow Engineering", "Warmflow", "Utility", "U120HE", "", "2005", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "26", "33", "", "", "87.9", "80.1", "", "58.5", "", "2", "", "", "201", "1", "1", "160", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.1", "94.7", "", "", "", "", "93.9"]} -{"pcdb_id": 10519, "brand_name": "Warmflow", "model_name": "Utility", "model_qualifier": "U90HE", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 26.0, "final_year_of_manufacture": null, "raw": ["010519", "000063", "0", "2013/Mar/28 08:27", "Warmflow Engineering", "Warmflow", "Utility", "U90HE", "", "2005", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "21", "26", "", "", "88.0", "80.2", "", "58.6", "", "2", "", "", "201", "1", "1", "160", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.8", "94.8", "", "", "", "", "94.1"]} -{"pcdb_id": 10520, "brand_name": "Warmflow", "model_name": "Utility", "model_qualifier": "U70HE", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 21.0, "final_year_of_manufacture": null, "raw": ["010520", "000063", "0", "2013/Mar/28 08:27", "Warmflow Engineering", "Warmflow", "Utility", "U70HE", "", "2005", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "15", "21", "", "", "87.9", "80.1", "", "58.5", "", "2", "", "", "201", "1", "1", "160", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "89.5", "95.0", "", "", "", "", "94.0"]} -{"pcdb_id": 10521, "brand_name": "Saunier Duval", "model_name": "SD Thema Condens F 18 E SB", "model_qualifier": "", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 17.9, "final_year_of_manufacture": null, "raw": ["010521", "000206", "0", "2012/Mar/27 10:12", "Vaillant Group", "Saunier Duval", "SD Thema Condens F 18 E SB", "", "", "2005", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "17.90", "17.90", "", "", "89.1", "80.1", "", "58.5", "", "2", "1", "", "102", "1", "2", "144", "8", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.0", "99.2", "", "", "", "", "97.4"]} -{"pcdb_id": 10522, "brand_name": "Saunier Duval", "model_name": "SD Thema Condens F 18 E SB", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 17.9, "final_year_of_manufacture": null, "raw": ["010522", "000206", "0", "2012/Mar/27 10:12", "Vaillant Group", "Saunier Duval", "SD Thema Condens F 18 E SB", "", "GC 41-920-47", "2005", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "17.90", "17.90", "", "", "88.1", "79.1", "", "57.8", "", "2", "", "", "102", "1", "2", "144", "8", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "97.0", "", "", "", "", "95.3"]} -{"pcdb_id": 10523, "brand_name": "Saunier Duval", "model_name": "SD Thema Condens F 24 E", "model_qualifier": "", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 56.6, "output_kw_max": 17.9, "final_year_of_manufacture": null, "raw": ["010523", "000206", "0", "2009/Mar/31 14:29", "Vaillant Group", "Saunier Duval", "SD Thema Condens F 24 E", "", "", "2005", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "17.90", "17.90", "", "", "89.1", "80.5", "", "56.6", "", "2", "1", "", "104", "1", "2", "142", "8", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.0", "99.2", "", "", "", "", "97.4"]} -{"pcdb_id": 10525, "brand_name": "Saunier Duval", "model_name": "SD Thema Condens F 24 E", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 55.9, "output_kw_max": 17.9, "final_year_of_manufacture": null, "raw": ["010525", "000206", "0", "2009/Mar/31 14:33", "Vaillant Group", "Saunier Duval", "SD Thema Condens F 24 E", "", "GC 47-920-48", "2005", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "17.90", "17.90", "", "", "88.1", "79.5", "", "55.9", "", "2", "", "", "104", "1", "2", "142", "8", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "97.0", "", "", "", "", "95.3"]} -{"pcdb_id": 10526, "brand_name": "Saunier Duval", "model_name": "SD Thema Condens F 30 E", "model_qualifier": "", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 80.6, "comparative_hot_water_efficiency_pct": 56.7, "output_kw_max": 23.6, "final_year_of_manufacture": null, "raw": ["010526", "000206", "0", "2009/Mar/31 14:29", "Vaillant Group", "Saunier Duval", "SD Thema Condens F 30 E", "", "", "2005", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "23.60", "23.60", "", "", "89.2", "80.6", "", "56.7", "", "2", "1", "", "104", "1", "2", "144", "8", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.2", "99.3", "", "", "", "", "97.6"]} -{"pcdb_id": 10527, "brand_name": "Saunier Duval", "model_name": "SD Thema Condens F 30 E", "model_qualifier": "", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 56.0, "output_kw_max": 23.6, "final_year_of_manufacture": null, "raw": ["010527", "000206", "0", "2009/Mar/31 14:33", "Vaillant Group", "Saunier Duval", "SD Thema Condens F 30 E", "", "GC 47-920-49", "2005", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "23.60", "23.60", "", "", "88.2", "79.6", "", "56.0", "", "2", "", "", "104", "1", "2", "144", "8", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.2", "97.1", "", "", "", "", "95.4"]} -{"pcdb_id": 10528, "brand_name": "Saunier Duval", "model_name": "SD Themaplus Condens F 30 E", "model_qualifier": "", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 80.6, "comparative_hot_water_efficiency_pct": 56.7, "output_kw_max": 23.6, "final_year_of_manufacture": null, "raw": ["010528", "000206", "0", "2009/Mar/31 14:29", "Vaillant Group", "Saunier Duval", "SD Themaplus Condens F 30 E", "", "", "2005", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "23.60", "23.60", "", "", "89.2", "80.6", "", "56.7", "", "2", "1", "", "104", "1", "2", "174", "8", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.2", "99.3", "", "", "", "", "97.6"]} -{"pcdb_id": 10529, "brand_name": "Saunier Duval", "model_name": "SD Themaplus Condens F 30 E", "model_qualifier": "", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 56.0, "output_kw_max": 23.6, "final_year_of_manufacture": null, "raw": ["010529", "000206", "0", "2009/Mar/31 14:34", "Vaillant Group", "Saunier Duval", "SD Themaplus Condens F 30 E", "", "GC 47-920-50", "2005", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "23.60", "23.60", "", "", "88.2", "79.6", "", "56.0", "", "2", "", "", "104", "1", "2", "174", "8", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.2", "97.1", "", "", "", "", "95.4"]} -{"pcdb_id": 10531, "brand_name": "Alpha", "model_name": "CD18R", "model_qualifier": "", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 18.0, "final_year_of_manufacture": null, "raw": ["010531", "000001", "0", "2012/Mar/27 10:12", "Alpha Therm", "Alpha", "CD18R", "", "", "2005", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "18.0", "18.0", "", "", "88.7", "79.7", "", "58.2", "", "2", "1", "", "102", "1", "2", "55", "2", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.3", "98.1", "", "", "", "", "96.6"]} -{"pcdb_id": 10532, "brand_name": "Sime", "model_name": "Dewy 30/80 HE FS", "model_qualifier": "", "winter_efficiency_pct": 90.3, "summer_efficiency_pct": 83.0, "comparative_hot_water_efficiency_pct": 47.1, "output_kw_max": 29.3, "final_year_of_manufacture": 2018, "raw": ["010532", "000213", "0", "2024/Jan/31 10:17", "Fonderie Sime S.p.A.", "Sime", "Dewy 30/80 HE FS", "", "", "2005", "2018", "2", "1", "1", "2", "0", "", "", "2", "3", "2", "29.3", "29.3", "", "", "90.3", "83.0", "", "47.1", "", "2", "1", "", "106", "1", "2", "175", "10", "2", "", "0", "80", "0", "25", "2", "60", "578", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.3", "102.2", "", "", "", "", "100.0"]} -{"pcdb_id": 10533, "brand_name": "Sime", "model_name": "Dewy 30/80 HE FS", "model_qualifier": "", "winter_efficiency_pct": 89.3, "summer_efficiency_pct": 82.0, "comparative_hot_water_efficiency_pct": 46.5, "output_kw_max": 29.3, "final_year_of_manufacture": 2018, "raw": ["010533", "000213", "0", "2024/Jan/31 10:17", "Fonderie Sime S.p.A.", "Sime", "Dewy 30/80 HE FS", "", "", "2005", "2018", "1", "1", "1", "2", "0", "", "", "2", "3", "2", "29.3", "29.3", "", "", "89.3", "82.0", "", "46.5", "", "2", "", "", "106", "1", "2", "175", "10", "2", "1", "0", "80", "0", "25", "", "60", "578", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "100.0", "", "", "", "", "97.8"]} -{"pcdb_id": 10534, "brand_name": "Sime", "model_name": "Dewy 30/130 HE FS", "model_qualifier": "", "winter_efficiency_pct": 90.3, "summer_efficiency_pct": 83.0, "comparative_hot_water_efficiency_pct": 44.8, "output_kw_max": 29.3, "final_year_of_manufacture": 2018, "raw": ["010534", "000213", "0", "2024/Jan/31 10:17", "Fonderie Sime S.p.A.", "Sime", "Dewy 30/130 HE FS", "", "", "2005", "2018", "2", "1", "1", "2", "0", "", "", "2", "3", "2", "29.3", "29.3", "", "", "90.3", "83.0", "", "44.8", "", "2", "1", "", "106", "1", "2", "175", "10", "2", "", "0", "130", "0", "30", "2", "60", "291", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.3", "102.2", "", "", "", "", "100.0"]} -{"pcdb_id": 10535, "brand_name": "Sime", "model_name": "Dewy 30/130 HE FS", "model_qualifier": "", "winter_efficiency_pct": 89.3, "summer_efficiency_pct": 82.0, "comparative_hot_water_efficiency_pct": 44.3, "output_kw_max": 29.3, "final_year_of_manufacture": 2018, "raw": ["010535", "000213", "0", "2024/Jan/31 10:17", "Fonderie Sime S.p.A.", "Sime", "Dewy 30/130 HE FS", "", "", "2005", "2018", "1", "1", "1", "2", "0", "", "", "2", "3", "2", "29.3", "29.3", "", "", "89.3", "82.0", "", "44.3", "", "2", "", "", "106", "1", "2", "175", "10", "2", "1", "0", "130", "0", "30", "2", "60", "291", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "100.0", "", "", "", "", "97.8"]} -{"pcdb_id": 10536, "brand_name": "Sime", "model_name": "Dewy HE 30/50 WM LPG", "model_qualifier": "", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 81.4, "comparative_hot_water_efficiency_pct": 52.0, "output_kw_max": 29.2, "final_year_of_manufacture": 2018, "raw": ["010536", "000213", "0", "2024/Jan/31 10:17", "Fonderie Sime S.p.A.", "Sime", "Dewy HE 30/50 WM LPG", "", "", "2005", "2018", "2", "2", "1", "2", "0", "", "", "2", "3", "2", "29.2", "29.2", "", "", "88.7", "81.4", "", "52.0", "", "2", "1", "", "106", "1", "2", "175", "10", "2", "", "0", "50", "0", "30", "2", "60", "246", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.5", "98.3", "", "", "", "", "96.6"]} -{"pcdb_id": 10537, "brand_name": "Sime", "model_name": "Dewy HE 30/50 WM", "model_qualifier": "", "winter_efficiency_pct": 87.7, "summer_efficiency_pct": 80.4, "comparative_hot_water_efficiency_pct": 51.4, "output_kw_max": 29.2, "final_year_of_manufacture": 2018, "raw": ["010537", "000213", "0", "2024/Jan/31 10:17", "Fonderie Sime S.p.A.", "Sime", "Dewy HE 30/50 WM", "", "", "2005", "2018", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "29.2", "29.2", "", "", "87.7", "80.4", "", "51.4", "", "2", "", "", "106", "1", "2", "175", "10", "2", "1", "0", "50", "0", "30", "2", "60", "246", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.6", "96.1", "", "", "", "", "94.5"]} -{"pcdb_id": 10538, "brand_name": "Sime", "model_name": "Ecomfort 30 HE LPG", "model_qualifier": "", "winter_efficiency_pct": 87.2, "summer_efficiency_pct": 78.6, "comparative_hot_water_efficiency_pct": 55.3, "output_kw_max": 29.1, "final_year_of_manufacture": 2018, "raw": ["010538", "000213", "0", "2018/Feb/26 16:49", "Fonderie Sime S.p.A.", "Sime", "Ecomfort 30 HE LPG", "", "", "2005", "2018", "2", "2", "1", "2", "0", "", "", "2", "3", "2", "29.1", "29.1", "", "", "87.2", "78.6", "", "55.3", "", "2", "1", "", "104", "1", "2", "180", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.2", "94.7", "", "", "", "", "93.6"]} -{"pcdb_id": 10539, "brand_name": "Sime", "model_name": "Ecomfort 30 HE", "model_qualifier": "", "winter_efficiency_pct": 86.2, "summer_efficiency_pct": 77.6, "comparative_hot_water_efficiency_pct": 54.6, "output_kw_max": 29.1, "final_year_of_manufacture": 2018, "raw": ["010539", "000213", "0", "2018/Feb/26 16:48", "Fonderie Sime S.p.A.", "Sime", "Ecomfort 30 HE", "", "", "2005", "2018", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "29.1", "29.1", "", "", "86.2", "77.6", "", "54.6", "", "2", "", "", "104", "1", "2", "180", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.3", "92.6", "", "", "", "", "91.6"]} -{"pcdb_id": 10540, "brand_name": "Ariston", "model_name": "Combi A 30 MFFI", "model_qualifier": "Combi A", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 56.6, "output_kw_max": 30.0, "final_year_of_manufacture": 2007, "raw": ["010540", "000080", "0", "2008/Jun/26 09:06", "Merloni TermoSanitari SpA", "Ariston", "Combi A 30 MFFI", "Combi A", "GC No. 47-116-45", "2005", "2007", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "30", "30", "", "", "89.1", "80.5", "", "56.6", "", "2", "", "", "104", "1", "2", "148", "7", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "99.4", "", "", "", "", "97.3"]} -{"pcdb_id": 10541, "brand_name": "Ariston", "model_name": "Combi A 24 MFFI", "model_qualifier": "Combi A", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 56.1, "output_kw_max": 25.0, "final_year_of_manufacture": 2007, "raw": ["010541", "000080", "0", "2008/Jun/26 09:06", "Merloni TermoSanitari SpA", "Ariston", "Combi A 24 MFFI", "Combi A", "GC No. 47-116-44", "2005", "2007", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "25", "25", "", "", "88.4", "79.8", "", "56.1", "", "2", "", "", "104", "1", "2", "148", "7", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "97.6", "", "", "", "", "95.8"]} -{"pcdb_id": 10542, "brand_name": "Ideal", "model_name": "Classic", "model_qualifier": "HE 15 P", "winter_efficiency_pct": 86.6, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 14.4, "final_year_of_manufacture": null, "raw": ["010542", "000008", "0", "2012/Mar/27 10:12", "Ideal Boilers", "Ideal", "Classic", "HE 15 P", "41-421-97", "2005", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "14.4", "14.4", "", "", "86.6", "79.0", "", "57.7", "", "2", "0", "", "101", "1", "1", "100", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "88.4", "94.6", "", "", "", "", "93.4"]} -{"pcdb_id": 10543, "brand_name": "Ideal", "model_name": "Classic", "model_qualifier": "HE 18 P", "winter_efficiency_pct": 85.7, "summer_efficiency_pct": 78.1, "comparative_hot_water_efficiency_pct": 57.1, "output_kw_max": 18.3, "final_year_of_manufacture": null, "raw": ["010543", "000008", "0", "2012/Mar/27 10:12", "Ideal Boilers", "Ideal", "Classic", "HE 18 P", "41-421-98", "2005", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "18.3", "18.3", "", "", "85.7", "78.1", "", "57.1", "", "2", "0", "", "101", "1", "1", "100", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "87.9", "92.6", "", "", "", "", "91.7"]} -{"pcdb_id": 10546, "brand_name": "Broag Remeha", "model_name": "Avanta Plus", "model_qualifier": "24s", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 22.0, "final_year_of_manufacture": null, "raw": ["010546", "000005", "0", "2012/Apr/11 14:49", "Remeha", "Broag Remeha", "Avanta Plus", "24s", "4128805", "2005", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "22", "22", "", "", "88.5", "79.5", "", "58.1", "", "2", "", "", "102", "1", "2", "115", "3", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.6", "97.9", "", "", "", "", "96.2"]} -{"pcdb_id": 10547, "brand_name": "Broag Remeha", "model_name": "Avanta Plus", "model_qualifier": "28c", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 56.2, "output_kw_max": 22.0, "final_year_of_manufacture": null, "raw": ["010547", "000005", "0", "2012/Apr/11 14:49", "Remeha", "Broag Remeha", "Avanta Plus", "28c", "4767302", "2005", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "22", "22", "", "", "88.5", "79.9", "", "56.2", "", "2", "", "", "104", "1", "2", "115", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.6", "97.9", "", "", "", "", "96.2"]} -{"pcdb_id": 10548, "brand_name": "Broag Remeha", "model_name": "Avanta Plus", "model_qualifier": "39c", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 56.6, "output_kw_max": 34.8, "final_year_of_manufacture": null, "raw": ["010548", "000005", "0", "2012/Apr/11 14:49", "Remeha", "Broag Remeha", "Avanta Plus", "39c", "4767304", "2005", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "34.8", "34.8", "", "", "89.1", "80.5", "", "56.6", "", "2", "", "", "104", "1", "2", "180", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "99.6", "", "", "", "", "97.4"]} -{"pcdb_id": 10549, "brand_name": "Sabre", "model_name": "25HE", "model_qualifier": "", "winter_efficiency_pct": 85.4, "summer_efficiency_pct": 76.8, "comparative_hot_water_efficiency_pct": 54.0, "output_kw_max": 24.3, "final_year_of_manufacture": null, "raw": ["010549", "000011", "0", "2006/Jan/17 12:31", "Vokera", "Sabre", "25HE", "", "4709470", "2005", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.3", "24.3", "", "", "85.4", "76.8", "", "54.0", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.4", "90.6", "", "", "", "", "90.0"]} -{"pcdb_id": 10550, "brand_name": "Sabre", "model_name": "29HE", "model_qualifier": "", "winter_efficiency_pct": 85.6, "summer_efficiency_pct": 77.0, "comparative_hot_water_efficiency_pct": 54.1, "output_kw_max": 28.1, "final_year_of_manufacture": null, "raw": ["010550", "000011", "0", "2006/Jan/17 12:31", "Vokera", "Sabre", "29HE", "", "4709471", "2005", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28.1", "28.1", "", "", "85.6", "77.0", "", "54.1", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.4", "90.9", "", "", "", "", "90.2"]} -{"pcdb_id": 10551, "brand_name": "Sabre", "model_name": "29HE", "model_qualifier": "System", "winter_efficiency_pct": 85.6, "summer_efficiency_pct": 76.6, "comparative_hot_water_efficiency_pct": 55.9, "output_kw_max": 28.1, "final_year_of_manufacture": null, "raw": ["010551", "000011", "0", "2012/Mar/27 10:12", "Vokera", "Sabre", "29HE", "System", "4709443", "2005", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "28.1", "28.1", "", "", "85.6", "76.6", "", "55.9", "", "2", "", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.4", "90.9", "", "", "", "", "90.2"]} -{"pcdb_id": 10552, "brand_name": "Vokera", "model_name": "Compact", "model_qualifier": "25HE", "winter_efficiency_pct": 85.4, "summer_efficiency_pct": 76.8, "comparative_hot_water_efficiency_pct": 54.0, "output_kw_max": 24.3, "final_year_of_manufacture": null, "raw": ["010552", "000011", "0", "2006/Jan/17 12:31", "Vokera", "Vokera", "Compact", "25HE", "4709474", "2005", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.3", "24.3", "", "", "85.4", "76.8", "", "54.0", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.4", "90.6", "", "", "", "", "90.0"]} -{"pcdb_id": 10554, "brand_name": "Vokera", "model_name": "Compact", "model_qualifier": "29HE", "winter_efficiency_pct": 85.6, "summer_efficiency_pct": 77.0, "comparative_hot_water_efficiency_pct": 54.1, "output_kw_max": 28.1, "final_year_of_manufacture": null, "raw": ["010554", "000011", "0", "2006/Jan/17 12:31", "Vokera", "Vokera", "Compact", "29HE", "4709476", "2005", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28.1", "28.1", "", "", "85.6", "77.0", "", "54.1", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.4", "90.9", "", "", "", "", "90.2"]} -{"pcdb_id": 10556, "brand_name": "Potterton", "model_name": "Gold", "model_qualifier": "33 HE", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 55.8, "output_kw_max": 28.0, "final_year_of_manufacture": 2008, "raw": ["010556", "000005", "0", "2010/Nov/19 09:18", "Baxi Potterton", "Potterton", "Gold", "33 HE", "GC No. 47-590-19", "2005", "2008", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28", "28", "", "", "87.9", "79.3", "", "55.8", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "96.7", "", "", "", "", "95.0"]} -{"pcdb_id": 10557, "brand_name": "Potterton", "model_name": "Gold", "model_qualifier": "28 HE", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 55.8, "output_kw_max": 24.0, "final_year_of_manufacture": 2008, "raw": ["010557", "000005", "0", "2010/Nov/19 09:18", "Baxi Potterton", "Potterton", "Gold", "28 HE", "GC No. 47-590-06", "2005", "2008", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "88.0", "79.4", "", "55.8", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "96.9", "", "", "", "", "95.2"]} -{"pcdb_id": 10558, "brand_name": "Baxi", "model_name": "Platinum", "model_qualifier": "33 HE", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 55.8, "output_kw_max": 28.0, "final_year_of_manufacture": 2007, "raw": ["010558", "000005", "0", "2010/Nov/19 09:04", "Baxi Potterton", "Baxi", "Platinum", "33 HE", "GC No. 47-075-22", "2005", "2007", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28", "28", "", "", "87.9", "79.3", "", "55.8", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "96.7", "", "", "", "", "95.0"]} -{"pcdb_id": 10559, "brand_name": "Baxi", "model_name": "Platinum", "model_qualifier": "28 HE", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 55.8, "output_kw_max": 24.0, "final_year_of_manufacture": 2007, "raw": ["010559", "000005", "0", "2010/Nov/19 09:03", "Baxi Potterton", "Baxi", "Platinum", "28 HE", "GC No. 47-075-21", "2005", "2007", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "88.0", "79.4", "", "55.8", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "96.9", "", "", "", "", "95.2"]} -{"pcdb_id": 10560, "brand_name": "SARIgas", "model_name": "Zoom", "model_qualifier": "ZF 420A", "winter_efficiency_pct": 79.2, "summer_efficiency_pct": 69.1, "comparative_hot_water_efficiency_pct": 48.6, "output_kw_max": 23.5, "final_year_of_manufacture": null, "raw": ["010560", "000244", "0", "2005/Sep/30 13:47", "SARIgas", "SARIgas", "Zoom", "ZF 420A", "", "2000", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "23.5", "23.5", "", "", "79.2", "69.1", "", "48.6", "", "2", "", "", "104", "1", "2", "140", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.5", "79.3", "", "", "", "", "79.7"]} -{"pcdb_id": 10561, "brand_name": "SARIgas", "model_name": "Max", "model_qualifier": "MF 25 A", "winter_efficiency_pct": 80.7, "summer_efficiency_pct": 71.6, "comparative_hot_water_efficiency_pct": 35.0, "output_kw_max": 29.1, "final_year_of_manufacture": null, "raw": ["010561", "000244", "0", "2024/Jan/31 10:17", "SARIgas", "SARIgas", "Max", "MF 25 A", "", "1998", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "29.1", "29.1", "", "", "80.7", "71.6", "", "35.0", "", "2", "", "", "106", "1", "2", "160", "10", "1", "1", "0", "59", "0", "20", "5", "60", "2", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.4", "80.8", "", "", "", "", "81.1"]} -{"pcdb_id": 10562, "brand_name": "Saunier Duval", "model_name": "Xeon Condens 30", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 28.17, "final_year_of_manufacture": null, "raw": ["010562", "000206", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Saunier Duval", "Xeon Condens 30", "", "GC 41-920-46", "2005", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "28.17", "28.17", "", "", "88.1", "79.1", "", "57.8", "", "2", "", "", "102", "1", "2", "60", "15", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.7", "96.9", "", "", "", "", "95.3"]} -{"pcdb_id": 10563, "brand_name": "Saunier Duval", "model_name": "Xeon Condens 30 LPG", "model_qualifier": "", "winter_efficiency_pct": 90.0, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 59.2, "output_kw_max": 28.17, "final_year_of_manufacture": null, "raw": ["010563", "000206", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Saunier Duval", "Xeon Condens 30 LPG", "", "", "2005", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "28.17", "28.17", "", "", "90.0", "81.0", "", "59.2", "", "2", "0", "", "102", "1", "2", "60", "15", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.8", "99.0", "", "", "", "", "97.3"]} -{"pcdb_id": 10564, "brand_name": "Saunier Duval", "model_name": "Xeon Condens 18", "model_qualifier": "", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 78.9, "comparative_hot_water_efficiency_pct": 57.6, "output_kw_max": 18.57, "final_year_of_manufacture": null, "raw": ["010564", "000206", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Saunier Duval", "Xeon Condens 18", "", "GC 41-920-38", "2005", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18.57", "18.57", "", "", "87.9", "78.9", "", "57.6", "", "2", "", "", "102", "1", "2", "60", "15", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.6", "96.3", "", "", "", "", "94.8"]} -{"pcdb_id": 10565, "brand_name": "Main", "model_name": "Combi", "model_qualifier": "30 HE", "winter_efficiency_pct": 85.8, "summer_efficiency_pct": 77.2, "comparative_hot_water_efficiency_pct": 54.3, "output_kw_max": 29.6, "final_year_of_manufacture": 2012, "raw": ["010565", "000005", "0", "2013/May/07 10:29", "Baxi Potterton", "Main", "Combi", "30 HE", "GC No. 47-474-03", "2005", "2012", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "29.6", "29.6", "", "", "85.8", "77.2", "", "54.3", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.6", "91.3", "", "", "", "", "90.6"]} -{"pcdb_id": 10566, "brand_name": "Johnson & Starley", "model_name": "Reno", "model_qualifier": "HE16H", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 16.0, "final_year_of_manufacture": null, "raw": ["010566", "000239", "0", "2012/Mar/27 10:12", "Johnson & Starley", "Johnson & Starley", "Reno", "HE16H", "4141607", "2005", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "16.0", "16.0", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "9.5", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.0", "97.3", "", "", "", "", "95.7"]} -{"pcdb_id": 10567, "brand_name": "Johnson & Starley", "model_name": "Reno", "model_qualifier": "HE16S", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 16.0, "final_year_of_manufacture": null, "raw": ["010567", "000239", "0", "2012/Mar/27 10:12", "Johnson & Starley", "Johnson & Starley", "Reno", "HE16S", "4141605", "2005", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "16.0", "16.0", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "145", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.0", "97.3", "", "", "", "", "95.7"]} -{"pcdb_id": 10568, "brand_name": "Johnson & Starley", "model_name": "Reno", "model_qualifier": "HE31H", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 30.0, "final_year_of_manufacture": null, "raw": ["010568", "000239", "0", "2012/Mar/27 10:12", "Johnson & Starley", "Johnson & Starley", "Reno", "HE31H", "4141606", "2005", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "30.0", "30.0", "", "", "88.1", "79.1", "", "57.8", "", "2", "", "", "102", "1", "2", "95", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "97.0", "", "", "", "", "95.3"]} -{"pcdb_id": 10569, "brand_name": "Johnson & Starley", "model_name": "Reno", "model_qualifier": "HE31S", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 30.0, "final_year_of_manufacture": null, "raw": ["010569", "000239", "0", "2012/Mar/27 10:12", "Johnson & Starley", "Johnson & Starley", "Reno", "HE31S", "4141604", "2005", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "30.0", "30.0", "", "", "88.1", "79.1", "", "57.8", "", "2", "", "", "102", "1", "2", "145", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "97.0", "", "", "", "", "95.3"]} -{"pcdb_id": 10570, "brand_name": "Johnson & Starley", "model_name": "Reno", "model_qualifier": "HE37C", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 55.9, "output_kw_max": 30.0, "final_year_of_manufacture": null, "raw": ["010570", "000239", "0", "2009/Oct/28 09:39", "Johnson & Starley", "Johnson & Starley", "Reno", "HE37C", "4141602", "2005", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "30.0", "30.0", "", "", "88.1", "79.5", "", "55.9", "", "2", "", "", "104", "1", "2", "145", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "97.0", "", "", "", "", "95.3"]} -{"pcdb_id": 10571, "brand_name": "Johnson & Starley", "model_name": "Reno", "model_qualifier": "HE16SP", "winter_efficiency_pct": 90.4, "summer_efficiency_pct": 81.4, "comparative_hot_water_efficiency_pct": 59.5, "output_kw_max": 16.0, "final_year_of_manufacture": null, "raw": ["010571", "000239", "0", "2012/Mar/27 10:12", "Johnson & Starley", "Johnson & Starley", "Reno", "HE16SP", "", "2005", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "16.0", "16.0", "", "", "90.4", "81.4", "", "59.5", "", "2", "0", "", "102", "1", "2", "145", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "91.0", "99.5", "", "", "", "", "97.9"]} -{"pcdb_id": 10572, "brand_name": "Johnson & Starley", "model_name": "Reno", "model_qualifier": "HE16HP", "winter_efficiency_pct": 90.4, "summer_efficiency_pct": 81.4, "comparative_hot_water_efficiency_pct": 59.5, "output_kw_max": 16.0, "final_year_of_manufacture": null, "raw": ["010572", "000239", "0", "2012/Mar/27 10:12", "Johnson & Starley", "Johnson & Starley", "Reno", "HE16HP", "", "2005", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "16.0", "16.0", "", "", "90.4", "81.4", "", "59.5", "", "2", "0", "", "102", "1", "2", "95", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "91.0", "99.5", "", "", "", "", "97.9"]} -{"pcdb_id": 10573, "brand_name": "Johnson & Starley", "model_name": "Reno", "model_qualifier": "HE31SP", "winter_efficiency_pct": 90.3, "summer_efficiency_pct": 81.3, "comparative_hot_water_efficiency_pct": 59.4, "output_kw_max": 30.0, "final_year_of_manufacture": null, "raw": ["010573", "000239", "0", "2012/Mar/27 10:12", "Johnson & Starley", "Johnson & Starley", "Reno", "HE31SP", "", "2005", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "30.0", "30.0", "", "", "90.3", "81.3", "", "59.4", "", "2", "0", "", "102", "1", "2", "145", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.5", "99.9", "", "", "", "", "98.0"]} -{"pcdb_id": 10574, "brand_name": "Johnson & Starley", "model_name": "Reno", "model_qualifier": "HE31HP", "winter_efficiency_pct": 90.3, "summer_efficiency_pct": 81.3, "comparative_hot_water_efficiency_pct": 59.4, "output_kw_max": 30.0, "final_year_of_manufacture": null, "raw": ["010574", "000239", "0", "2012/Mar/27 10:12", "Johnson & Starley", "Johnson & Starley", "Reno", "HE31HP", "", "2005", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "30.0", "30.0", "", "", "90.3", "81.3", "", "59.4", "", "2", "0", "", "102", "1", "2", "95", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.5", "99.9", "", "", "", "", "98.0"]} -{"pcdb_id": 10575, "brand_name": "Johnson & Starley", "model_name": "Reno", "model_qualifier": "HE37CP", "winter_efficiency_pct": 90.3, "summer_efficiency_pct": 81.7, "comparative_hot_water_efficiency_pct": 57.5, "output_kw_max": 30.0, "final_year_of_manufacture": null, "raw": ["010575", "000239", "0", "2006/Jan/17 12:31", "Johnson & Starley", "Johnson & Starley", "Reno", "HE37CP", "", "2005", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "30.0", "30.0", "", "", "90.3", "81.7", "", "57.5", "", "2", "0", "", "104", "1", "2", "145", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.5", "99.9", "", "", "", "", "98.0"]} -{"pcdb_id": 10577, "brand_name": "Biasi", "model_name": "Riva Advance HE", "model_qualifier": "M110.24SM/C", "winter_efficiency_pct": 87.8, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 55.7, "output_kw_max": 25.0, "final_year_of_manufacture": null, "raw": ["010577", "000208", "0", "2006/Jan/17 12:31", "Biasi", "Biasi", "Riva Advance HE", "M110.24SM/C", "47-970-29", "2004", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "25", "25", "", "", "87.8", "79.2", "", "55.7", "", "2", "", "", "104", "1", "2", "108", "6", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "96.4", "", "", "", "", "94.8"]} -{"pcdb_id": 10578, "brand_name": "Biasi", "model_name": "Garda Plus HE Silver", "model_qualifier": "M110.24SM/D", "winter_efficiency_pct": 87.8, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 55.7, "output_kw_max": 25.0, "final_year_of_manufacture": 2008, "raw": ["010578", "000208", "0", "2008/May/22 11:20", "Biasi", "Biasi", "Garda Plus HE Silver", "M110.24SM/D", "47-970-33", "2004", "2008", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "25", "25", "", "", "87.8", "79.2", "", "55.7", "", "2", "", "", "104", "1", "2", "108", "6", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "96.4", "", "", "", "", "94.8"]} -{"pcdb_id": 10579, "brand_name": "Biasi", "model_name": "Garda Plus HE", "model_qualifier": "M110.24SM/E", "winter_efficiency_pct": 87.8, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 55.7, "output_kw_max": 25.0, "final_year_of_manufacture": null, "raw": ["010579", "000208", "0", "2006/Jan/17 12:31", "Biasi", "Biasi", "Garda Plus HE", "M110.24SM/E", "47-970-31", "2004", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "25", "25", "", "", "87.8", "79.2", "", "55.7", "", "2", "", "", "104", "1", "2", "108", "6", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "96.4", "", "", "", "", "94.8"]} -{"pcdb_id": 10580, "brand_name": "Biasi", "model_name": "Riva Advance HE", "model_qualifier": "M110.32SM/C", "winter_efficiency_pct": 87.8, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 55.7, "output_kw_max": 33.5, "final_year_of_manufacture": null, "raw": ["010580", "000208", "0", "2006/Jan/17 12:31", "Biasi", "Biasi", "Riva Advance HE", "M110.32SM/C", "47-970-30", "2004", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "33.5", "33.5", "", "", "87.8", "79.2", "", "55.7", "", "2", "", "", "104", "1", "2", "125", "6", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "96.2", "", "", "", "", "94.7"]} -{"pcdb_id": 10581, "brand_name": "Biasi", "model_name": "Garda Plus HE Silver", "model_qualifier": "M110.32SM/D", "winter_efficiency_pct": 87.8, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 55.7, "output_kw_max": 33.5, "final_year_of_manufacture": 2008, "raw": ["010581", "000208", "0", "2008/May/22 11:20", "Biasi", "Biasi", "Garda Plus HE Silver", "M110.32SM/D", "47-970-34", "2004", "2008", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "33.5", "33.5", "", "", "87.8", "79.2", "", "55.7", "", "2", "", "", "104", "1", "2", "125", "6", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "96.2", "", "", "", "", "94.7"]} -{"pcdb_id": 10582, "brand_name": "Biasi", "model_name": "Garda Plus HE", "model_qualifier": "M110.32SM/E", "winter_efficiency_pct": 87.8, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 55.7, "output_kw_max": 33.5, "final_year_of_manufacture": null, "raw": ["010582", "000208", "0", "2006/Jan/17 12:31", "Biasi", "Biasi", "Garda Plus HE", "M110.32SM/E", "47-970-32", "2004", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "33.5", "33.5", "", "", "87.8", "79.2", "", "55.7", "", "2", "", "", "104", "1", "2", "125", "6", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "96.2", "", "", "", "", "94.7"]} -{"pcdb_id": 10583, "brand_name": "Baxi", "model_name": "Platinum System", "model_qualifier": "24 HE", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 24.0, "final_year_of_manufacture": 2007, "raw": ["010583", "000005", "0", "2012/Mar/27 10:12", "Baxi Potterton", "Baxi", "Platinum System", "24 HE", "GC No. 41-077-92", "2005", "2007", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24", "24", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "96.9", "", "", "", "", "95.1"]} -{"pcdb_id": 10584, "brand_name": "Main", "model_name": "9 HE", "model_qualifier": "", "winter_efficiency_pct": 84.0, "summer_efficiency_pct": 76.4, "comparative_hot_water_efficiency_pct": 55.8, "output_kw_max": 8.82, "final_year_of_manufacture": 2011, "raw": ["010584", "000005", "0", "2013/May/07 10:29", "Baxi Potterton", "Main", "9 HE", "", "GC No. 41-474-01", "2005", "2011", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "8.82", "8.82", "", "", "84.0", "76.4", "", "55.8", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "86.3", "90.9", "", "", "", "", "90.0"]} -{"pcdb_id": 10585, "brand_name": "Main", "model_name": "12 HE", "model_qualifier": "", "winter_efficiency_pct": 84.2, "summer_efficiency_pct": 76.6, "comparative_hot_water_efficiency_pct": 55.9, "output_kw_max": 11.78, "final_year_of_manufacture": 2011, "raw": ["010585", "000005", "0", "2013/May/07 10:30", "Baxi Potterton", "Main", "12 HE", "", "GC No. 41-474-02", "2005", "2011", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "11.78", "11.78", "", "", "84.2", "76.6", "", "55.9", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "86.5", "91.3", "", "", "", "", "90.4"]} -{"pcdb_id": 10586, "brand_name": "Main", "model_name": "15 HE", "model_qualifier": "", "winter_efficiency_pct": 84.0, "summer_efficiency_pct": 76.4, "comparative_hot_water_efficiency_pct": 55.8, "output_kw_max": 14.76, "final_year_of_manufacture": 2011, "raw": ["010586", "000005", "0", "2013/May/07 10:30", "Baxi Potterton", "Main", "15 HE", "", "GC No. 41-474-03", "2005", "2011", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "14.76", "14.76", "", "", "84.0", "76.4", "", "55.8", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "86.7", "90.7", "", "", "", "", "90.0"]} -{"pcdb_id": 10587, "brand_name": "Main", "model_name": "18 HE", "model_qualifier": "", "winter_efficiency_pct": 84.0, "summer_efficiency_pct": 76.4, "comparative_hot_water_efficiency_pct": 55.8, "output_kw_max": 17.72, "final_year_of_manufacture": 2011, "raw": ["010587", "000005", "0", "2013/May/07 10:30", "Baxi Potterton", "Main", "18 HE", "", "GC No. 41-474-04", "2005", "2011", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "17.72", "17.72", "", "", "84.0", "76.4", "", "55.8", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "86.8", "90.6", "", "", "", "", "89.9"]} -{"pcdb_id": 10588, "brand_name": "Main", "model_name": "24 HE", "model_qualifier": "", "winter_efficiency_pct": 84.0, "summer_efficiency_pct": 76.4, "comparative_hot_water_efficiency_pct": 55.8, "output_kw_max": 23.63, "final_year_of_manufacture": 2011, "raw": ["010588", "000005", "0", "2013/May/07 10:30", "Baxi Potterton", "Main", "24 HE", "", "GC No. 41-474-05", "2005", "2011", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "23.63", "23.63", "", "", "84.0", "76.4", "", "55.8", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "86.8", "90.6", "", "", "", "", "89.9"]} -{"pcdb_id": 10589, "brand_name": "Saunier Duval", "model_name": "Semia Condens F30E", "model_qualifier": "", "winter_efficiency_pct": 85.5, "summer_efficiency_pct": 76.9, "comparative_hot_water_efficiency_pct": 54.1, "output_kw_max": 28.6, "final_year_of_manufacture": null, "raw": ["010589", "000206", "0", "2006/Jan/17 12:31", "Saunier Duval", "Saunier Duval", "Semia Condens F30E", "", "", "2005", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28.6", "28.6", "", "", "85.5", "76.9", "", "54.1", "", "2", "", "", "104", "1", "2", "150", "70", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.5", "90.6", "", "", "", "", "90.0"]} -{"pcdb_id": 10590, "brand_name": "Saunier Duval", "model_name": "Semia Condens F24E", "model_qualifier": "", "winter_efficiency_pct": 85.5, "summer_efficiency_pct": 76.9, "comparative_hot_water_efficiency_pct": 54.1, "output_kw_max": 24.5, "final_year_of_manufacture": null, "raw": ["010590", "000206", "0", "2006/Jan/17 12:31", "Saunier Duval", "Saunier Duval", "Semia Condens F24E", "", "", "2005", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.5", "24.5", "", "", "85.5", "76.9", "", "54.1", "", "2", "", "", "104", "1", "2", "145", "75", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "86.3", "91.1", "", "", "", "", "90.2"]} -{"pcdb_id": 10591, "brand_name": "Gerkros", "model_name": "Termogas", "model_qualifier": "KT", "winter_efficiency_pct": 87.5, "summer_efficiency_pct": 78.5, "comparative_hot_water_efficiency_pct": 57.3, "output_kw_max": 21.6, "final_year_of_manufacture": null, "raw": ["010591", "000245", "0", "2012/Mar/27 10:12", "Gerkros Boilers (Tipperary) Limited", "Gerkros", "Termogas", "KT", "", "2005", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "1", "21.6", "21.6", "", "", "87.5", "78.5", "", "57.3", "", "2", "", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "86.7", "96.0", "", "", "", "", "94.3"]} -{"pcdb_id": 10592, "brand_name": "Gerkros", "model_name": "Termogas", "model_qualifier": "KST", "winter_efficiency_pct": 84.7, "summer_efficiency_pct": 76.1, "comparative_hot_water_efficiency_pct": 53.5, "output_kw_max": 21.6, "final_year_of_manufacture": null, "raw": ["010592", "000245", "0", "2005/Nov/30 11:26", "Gerkros Boilers (Tipperary) Limited", "Gerkros", "Termogas", "KST", "", "2005", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "1", "21.6", "21.6", "", "", "84.7", "76.1", "", "53.5", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "84.9", "90.8", "", "", "", "", "89.7"]} -{"pcdb_id": 10593, "brand_name": "Baxi", "model_name": "Platinum", "model_qualifier": "15 HE", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 15.24, "final_year_of_manufacture": 2007, "raw": ["010593", "000005", "0", "2012/Mar/27 10:12", "Baxi Potterton", "Baxi", "Platinum", "15 HE", "GC No. 41-077-90", "2005", "2007", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "15.24", "15.24", "", "", "88.7", "79.7", "", "58.2", "", "2", "", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.3", "97.7", "", "", "", "", "96.3"]} -{"pcdb_id": 10594, "brand_name": "Warmflow", "model_name": "Utility", "model_qualifier": "U90", "winter_efficiency_pct": 86.6, "summer_efficiency_pct": 74.9, "comparative_hot_water_efficiency_pct": 54.7, "output_kw_max": 26.0, "final_year_of_manufacture": null, "raw": ["010594", "000063", "0", "2012/Mar/27 10:12", "Warmflow Engineering", "Warmflow", "Utility", "U90", "", "2005", "current", "4", "1", "1", "1", "0", "", "", "1", "3", "2", "15", "26", "", "", "86.6", "74.9", "", "54.7", "", "2", "", "", "201", "1", "1", "125", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.0", "88.5", "", "", "", "", "88.0"]} -{"pcdb_id": 10595, "brand_name": "Kidd VHE", "model_name": "2", "model_qualifier": "Natural Gas", "winter_efficiency_pct": 84.1, "summer_efficiency_pct": 76.5, "comparative_hot_water_efficiency_pct": 55.9, "output_kw_max": 45.0, "final_year_of_manufacture": null, "raw": ["010595", "000204", "0", "2012/Mar/27 10:12", "Archie Kidd (Thermal)", "Kidd VHE", "2", "Natural Gas", "", "2005", "current", "1", "1", "1", "1", "0", "", "", "2", "3", "2", "29.3", "45.0", "", "", "84.1", "76.5", "", "55.9", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "86.5", "91.2", "", "", "", "", "90.3"]} -{"pcdb_id": 10596, "brand_name": "Trianco", "model_name": "Tristar Optima", "model_qualifier": "Junior K System 24 SB", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 25.0, "final_year_of_manufacture": 2007, "raw": ["010596", "000062", "0", "2012/Mar/27 10:12", "Trianco", "Trianco", "Tristar Optima", "Junior K System 24 SB", "GC 47 897 06", "2005", "2007", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "25", "25", "", "", "88.1", "79.1", "", "57.8", "", "2", "1", "", "102", "1", "2", "135", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.7", "96.7", "", "", "", "", "95.2"]} -{"pcdb_id": 10597, "brand_name": "Trianco", "model_name": "Tristar Optima", "model_qualifier": "Junior K Combi 24 CB", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 55.9, "output_kw_max": 25.0, "final_year_of_manufacture": 2007, "raw": ["010597", "000062", "0", "2009/Mar/24 12:05", "Trianco", "Trianco", "Tristar Optima", "Junior K Combi 24 CB", "GC 41 898 39", "2005", "2007", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "25", "25", "", "", "88.1", "79.5", "", "55.9", "", "2", "", "", "104", "1", "2", "135", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "0", "0", "0005", "", "", "", "", "", "", "", "", "88.7", "96.7", "", "", "", "", "95.2"]} -{"pcdb_id": 10598, "brand_name": "Grant", "model_name": "Vortex", "model_qualifier": "Outdoor Condensing Combi 36", "winter_efficiency_pct": 90.5, "summer_efficiency_pct": 84.4, "comparative_hot_water_efficiency_pct": 46.2, "output_kw_max": 36.0, "final_year_of_manufacture": null, "raw": ["010598", "000048", "0", "2024/Jan/31 10:17", "Grant Engineering (UK)", "Grant", "Vortex", "Outdoor Condensing Combi 36", "", "2005", "current", "4", "1", "2", "2", "0", "", "", "2", "3", "2", "36", "36", "", "", "90.5", "84.4", "", "46.2", "", "2", "", "", "203", "1", "1", "", "", "1", "", "", "40", "0", "25", "3", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "95.1", "99.3", "", "", "", "", "98.5"]} -{"pcdb_id": 10599, "brand_name": "Grant", "model_name": "Vortex", "model_qualifier": "Outdoor Condensing Combi 26", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 83.0, "comparative_hot_water_efficiency_pct": 45.4, "output_kw_max": 26.0, "final_year_of_manufacture": null, "raw": ["010599", "000048", "0", "2024/Jan/31 10:17", "Grant Engineering (UK)", "Grant", "Vortex", "Outdoor Condensing Combi 26", "", "2005", "current", "4", "1", "2", "2", "0", "", "", "2", "3", "2", "26", "26", "", "", "89.1", "83.0", "", "45.4", "", "2", "", "", "203", "1", "1", "", "", "1", "", "", "40", "0", "25", "3", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "93.6", "96.4", "", "", "", "", "95.9"]} -{"pcdb_id": 10600, "brand_name": "Firebird", "model_name": "Combipac C20", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 82.2, "comparative_hot_water_efficiency_pct": 45.0, "output_kw_max": 20.0, "final_year_of_manufacture": 2010, "raw": ["010600", "000047", "0", "2024/Jan/31 10:17", "Firebird Boilers", "Firebird", "Combipac C20", "", "", "2005", "2010", "4", "1", "2", "2", "0", "", "", "2", "2", "1", "15", "20", "", "", "88.3", "82.2", "", "45.0", "", "2", "", "", "203", "1", "1", "138", "0", "1", "1", "0", "40", "0", "25", "1", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.7", "95.2", "", "", "", "", "94.5"]} -{"pcdb_id": 10601, "brand_name": "Firebird", "model_name": "Combipac C26", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 82.2, "comparative_hot_water_efficiency_pct": 45.0, "output_kw_max": 26.0, "final_year_of_manufacture": 2010, "raw": ["010601", "000047", "0", "2024/Jan/31 10:17", "Firebird Boilers", "Firebird", "Combipac C26", "", "", "2005", "2010", "4", "1", "2", "2", "0", "", "", "2", "2", "1", "20", "26", "", "", "88.3", "82.2", "", "45.0", "", "2", "", "", "203", "1", "1", "138", "0", "1", "1", "0", "40", "0", "25", "1", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.5", "95.3", "", "", "", "", "94.6"]} -{"pcdb_id": 10602, "brand_name": "Firebird", "model_name": "Combipac C35", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 82.0, "comparative_hot_water_efficiency_pct": 44.9, "output_kw_max": 35.0, "final_year_of_manufacture": 2010, "raw": ["010602", "000047", "0", "2024/Jan/31 10:17", "Firebird Boilers", "Firebird", "Combipac C35", "", "", "2005", "2010", "4", "1", "2", "2", "0", "", "", "2", "2", "1", "26", "35", "", "", "88.1", "82.0", "", "44.9", "", "2", "", "", "203", "1", "1", "138", "0", "1", "1", "0", "40", "0", "25", "1", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.4", "94.9", "", "", "", "", "94.2"]} -{"pcdb_id": 10603, "brand_name": "Firebird", "model_name": "Heatpac C20", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 58.8, "output_kw_max": 20.0, "final_year_of_manufacture": 2010, "raw": ["010603", "000047", "0", "2012/Mar/27 10:12", "Firebird Boilers", "Firebird", "Heatpac C20", "", "", "2005", "2010", "4", "1", "2", "1", "0", "", "", "2", "2", "1", "15", "20", "", "", "88.3", "80.5", "", "58.8", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.7", "95.2", "", "", "", "", "94.5"]} -{"pcdb_id": 10604, "brand_name": "Firebird", "model_name": "Heatpac C26", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 58.8, "output_kw_max": 26.0, "final_year_of_manufacture": 2010, "raw": ["010604", "000047", "0", "2012/Mar/27 10:12", "Firebird Boilers", "Firebird", "Heatpac C26", "", "", "2005", "2010", "4", "1", "2", "1", "0", "", "", "2", "2", "1", "20", "26", "", "", "88.3", "80.5", "", "58.8", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.5", "95.3", "", "", "", "", "94.6"]} -{"pcdb_id": 10605, "brand_name": "Firebird", "model_name": "Heatpac C35", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 58.7, "output_kw_max": 35.0, "final_year_of_manufacture": 2010, "raw": ["010605", "000047", "0", "2012/Mar/27 10:12", "Firebird Boilers", "Firebird", "Heatpac C35", "", "", "2005", "2010", "4", "1", "2", "1", "0", "", "", "2", "2", "1", "26", "35", "", "", "88.1", "80.3", "", "58.7", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.4", "94.9", "", "", "", "", "94.2"]} -{"pcdb_id": 10606, "brand_name": "Firebird", "model_name": "System C20", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 58.8, "output_kw_max": 20.0, "final_year_of_manufacture": 2010, "raw": ["010606", "000047", "0", "2012/Mar/27 10:12", "Firebird Boilers", "Firebird", "System C20", "", "", "2005", "2010", "4", "1", "1", "1", "0", "", "", "2", "2", "1", "15", "20", "", "", "88.3", "80.5", "", "58.8", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.7", "95.2", "", "", "", "", "94.5"]} -{"pcdb_id": 10607, "brand_name": "Firebird", "model_name": "System C26", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 58.8, "output_kw_max": 26.0, "final_year_of_manufacture": 2010, "raw": ["010607", "000047", "0", "2012/Mar/27 10:12", "Firebird Boilers", "Firebird", "System C26", "", "", "2005", "2010", "4", "1", "1", "1", "0", "", "", "2", "2", "1", "20", "26", "", "", "88.3", "80.5", "", "58.8", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.5", "95.3", "", "", "", "", "94.6"]} -{"pcdb_id": 10608, "brand_name": "Firebird", "model_name": "System C35", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 58.7, "output_kw_max": 35.0, "final_year_of_manufacture": 2010, "raw": ["010608", "000047", "0", "2012/Mar/27 10:12", "Firebird Boilers", "Firebird", "System C35", "", "", "2005", "2010", "4", "1", "1", "1", "0", "", "", "2", "2", "1", "26", "35", "", "", "88.1", "80.3", "", "58.7", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.4", "94.9", "", "", "", "", "94.2"]} -{"pcdb_id": 10609, "brand_name": "Firebird", "model_name": "Systempac C35", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 58.7, "output_kw_max": 35.0, "final_year_of_manufacture": 2010, "raw": ["010609", "000047", "0", "2012/Mar/27 10:12", "Firebird Boilers", "Firebird", "Systempac C35", "", "", "2005", "2010", "4", "1", "2", "1", "0", "", "", "2", "2", "1", "26", "35", "", "", "88.1", "80.3", "", "58.7", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.4", "94.9", "", "", "", "", "94.2"]} -{"pcdb_id": 10610, "brand_name": "Firebird", "model_name": "Systempac C26", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 58.8, "output_kw_max": 26.0, "final_year_of_manufacture": 2010, "raw": ["010610", "000047", "0", "2012/Mar/27 10:12", "Firebird Boilers", "Firebird", "Systempac C26", "", "", "2005", "2010", "4", "1", "2", "1", "0", "", "", "2", "2", "1", "20", "26", "", "", "88.3", "80.5", "", "58.8", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.5", "95.3", "", "", "", "", "94.6"]} -{"pcdb_id": 10611, "brand_name": "Firebird", "model_name": "Systempac C20", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 58.8, "output_kw_max": 20.0, "final_year_of_manufacture": 2010, "raw": ["010611", "000047", "0", "2012/Mar/27 10:12", "Firebird Boilers", "Firebird", "Systempac C20", "", "", "2005", "2010", "4", "1", "2", "1", "0", "", "", "2", "2", "1", "15", "20", "", "", "88.3", "80.5", "", "58.8", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.7", "95.2", "", "", "", "", "94.5"]} -{"pcdb_id": 10612, "brand_name": "Halstead", "model_name": "Ace", "model_qualifier": "HE 24", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 55.9, "output_kw_max": 18.0, "final_year_of_manufacture": null, "raw": ["010612", "000019", "0", "2006/Jan/30 20:19", "Halstead Boilers", "Halstead", "Ace", "HE 24", "4733319", "2005", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "18", "18", "", "", "88.2", "79.6", "", "55.9", "", "2", "", "", "104", "1", "2", "140", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "97.2", "", "", "", "", "95.5"]} -{"pcdb_id": 10613, "brand_name": "Halstead", "model_name": "Ace", "model_qualifier": "HE 30", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 56.0, "output_kw_max": 23.1, "final_year_of_manufacture": null, "raw": ["010613", "000019", "0", "2006/Jan/30 20:19", "Halstead Boilers", "Halstead", "Ace", "HE 30", "4733320", "2005", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "23.1", "23.1", "", "", "88.2", "79.6", "", "56.0", "", "2", "", "", "104", "1", "2", "160", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "97.3", "", "", "", "", "95.5"]} -{"pcdb_id": 10614, "brand_name": "Ariston", "model_name": "ACO 35 HP MFFI", "model_qualifier": "ACO 35 HP MFFI", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 56.1, "output_kw_max": 29.4, "final_year_of_manufacture": 2007, "raw": ["010614", "000080", "0", "2008/Jun/26 09:06", "Merloni TermoSanitari SpA", "Ariston", "ACO 35 HP MFFI", "ACO 35 HP MFFI", "GC No. 47-116-35", "2005", "2007", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "29.4", "29.4", "", "", "88.3", "79.7", "", "56.1", "", "2", "", "", "104", "1", "2", "148", "7", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.2", "97.5", "", "", "", "", "95.7"]} -{"pcdb_id": 10615, "brand_name": "Potterton", "model_name": "Promax FSB", "model_qualifier": "30 HE", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 30.18, "final_year_of_manufacture": 2015, "raw": ["010615", "000005", "0", "2015/Aug/06 12:50", "Baxi Potterton", "Potterton", "Promax FSB", "30 HE", "GC No. 41-595-39", "2006", "2015", "1", "1", "1", "1", "0", "", "", "2", "2", "2", "30.18", "30.18", "", "", "88.1", "79.1", "", "57.8", "", "2", "", "", "102", "1", "2", "80", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.4", "96.4", "", "", "", "", "95.1"]} -{"pcdb_id": 10616, "brand_name": "Alpha", "model_name": "CD18S", "model_qualifier": "", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 78.9, "comparative_hot_water_efficiency_pct": 57.6, "output_kw_max": 18.0, "final_year_of_manufacture": 2007, "raw": ["010616", "000001", "0", "2012/Mar/27 10:12", "Alpha Therm", "Alpha", "CD18S", "", "", "2005", "2007", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18", "18", "", "", "87.9", "78.9", "", "57.6", "", "2", "", "", "102", "1", "2", "125", "2", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.7", "96.2", "", "", "", "", "94.8"]} -{"pcdb_id": 10617, "brand_name": "Alpha", "model_name": "CD18S", "model_qualifier": "", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 18.0, "final_year_of_manufacture": 2007, "raw": ["010617", "000001", "0", "2012/Mar/27 10:12", "Alpha Therm", "Alpha", "CD18S", "", "", "2005", "2007", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "18", "18", "", "", "88.9", "79.9", "", "58.4", "", "2", "1", "", "102", "1", "2", "125", "2", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.7", "98.4", "", "", "", "", "96.9"]} -{"pcdb_id": 10618, "brand_name": "Grant", "model_name": "Vortex", "model_qualifier": "Utility 46-58", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 81.1, "comparative_hot_water_efficiency_pct": 59.2, "output_kw_max": 60.0, "final_year_of_manufacture": null, "raw": ["010618", "000048", "0", "2015/Sep/03 13:09", "Grant Engineering", "Grant", "Vortex", "Utility 46-58", "", "2006", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "46", "60", "", "", "88.9", "81.1", "", "59.2", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.5", "96.7", "", "", "", "", "95.7"]} -{"pcdb_id": 10619, "brand_name": "Grant", "model_name": "Vortex", "model_qualifier": "Utility 58-70", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 59.0, "output_kw_max": 70.0, "final_year_of_manufacture": null, "raw": ["010619", "000048", "0", "2015/Sep/03 13:11", "Grant Engineering", "Grant", "Vortex", "Utility 58-70", "", "2006", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "60", "70", "", "", "88.6", "80.8", "", "59.0", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.9", "96.2", "", "", "", "", "95.2"]} -{"pcdb_id": 10620, "brand_name": "Viessmann", "model_name": "Vitodens 100 Compact", "model_qualifier": "WB1A 8-24kW", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 24.0, "final_year_of_manufacture": 2007, "raw": ["010620", "000033", "0", "2012/Mar/27 10:12", "Viessmann", "Viessmann", "Vitodens 100 Compact", "WB1A 8-24kW", "41-819-10", "", "2007", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24", "24", "", "", "88.5", "79.5", "", "58.1", "", "2", "", "", "102", "1", "2", "51", "6", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.6", "97.8", "", "", "", "", "96.0"]} -{"pcdb_id": 10621, "brand_name": "Viessmann", "model_name": "Vitodens 100 Compact", "model_qualifier": "WB1A 8-18kW", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 18.0, "final_year_of_manufacture": 2007, "raw": ["010621", "000033", "0", "2012/Mar/27 10:12", "Viessmann", "Viessmann", "Vitodens 100 Compact", "WB1A 8-18kW", "41-819-12", "", "2007", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18", "18", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "35", "6", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.5", "97.6", "", "", "", "", "95.8"]} -{"pcdb_id": 10622, "brand_name": "Sime", "model_name": "Format 80 C TS", "model_qualifier": "", "winter_efficiency_pct": 81.3, "summer_efficiency_pct": 71.2, "comparative_hot_water_efficiency_pct": 50.1, "output_kw_max": 23.7, "final_year_of_manufacture": 2018, "raw": ["010622", "000213", "0", "2018/Feb/26 17:06", "Fonderie Sime S.p.A.", "Sime", "Format 80 C TS", "", "", "2006", "2018", "1", "2", "1", "2", "0", "", "", "1", "3", "2", "23.7", "23.7", "", "", "81.3", "71.2", "", "50.1", "", "2", "", "", "104", "1", "2", "120", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "83.9", "82.2", "", "", "", "", "82.5"]} -{"pcdb_id": 10623, "brand_name": "Sime", "model_name": "Format 80 C TS LPG", "model_qualifier": "", "winter_efficiency_pct": 83.1, "summer_efficiency_pct": 73.0, "comparative_hot_water_efficiency_pct": 51.3, "output_kw_max": 23.7, "final_year_of_manufacture": 2018, "raw": ["010623", "000213", "0", "2018/Feb/26 17:07", "Fonderie Sime S.p.A.", "Sime", "Format 80 C TS LPG", "", "", "2006", "2018", "2", "2", "1", "2", "0", "", "", "1", "3", "2", "23.7", "23.7", "", "", "83.1", "73.0", "", "51.3", "", "2", "1", "", "104", "1", "2", "120", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "85.7", "84.0", "", "", "", "", "84.3"]} -{"pcdb_id": 10624, "brand_name": "Sime", "model_name": "Format 100 C TS", "model_qualifier": "", "winter_efficiency_pct": 82.1, "summer_efficiency_pct": 72.0, "comparative_hot_water_efficiency_pct": 50.6, "output_kw_max": 28.0, "final_year_of_manufacture": 2018, "raw": ["010624", "000213", "0", "2018/Feb/26 16:59", "Fonderie Sime S.p.A.", "Sime", "Format 100 C TS", "", "", "2006", "2018", "1", "2", "1", "2", "0", "", "", "1", "3", "2", "28", "28.0", "", "", "82.1", "72.0", "", "50.6", "", "2", "", "", "104", "1", "2", "120", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "84.3", "83.6", "", "", "", "", "83.7"]} -{"pcdb_id": 10625, "brand_name": "Sime", "model_name": "Format 100 C TS LPG", "model_qualifier": "", "winter_efficiency_pct": 83.1, "summer_efficiency_pct": 73.0, "comparative_hot_water_efficiency_pct": 51.3, "output_kw_max": 28.0, "final_year_of_manufacture": 2018, "raw": ["010625", "000213", "0", "2018/Feb/26 17:00", "Fonderie Sime S.p.A.", "Sime", "Format 100 C TS LPG", "", "", "2006", "2018", "2", "2", "1", "2", "0", "", "", "1", "3", "2", "28", "28.0", "", "", "83.1", "73.0", "", "51.3", "", "2", "1", "", "104", "1", "2", "120", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "86.2", "85.5", "", "", "", "", "85.6"]} -{"pcdb_id": 10626, "brand_name": "Sime", "model_name": "Format 110 C TS", "model_qualifier": "", "winter_efficiency_pct": 81.9, "summer_efficiency_pct": 71.8, "comparative_hot_water_efficiency_pct": 50.5, "output_kw_max": 32.4, "final_year_of_manufacture": 2018, "raw": ["010626", "000213", "0", "2018/Feb/26 17:02", "Fonderie Sime S.p.A.", "Sime", "Format 110 C TS", "", "", "2006", "2018", "1", "2", "1", "2", "0", "", "", "1", "3", "2", "32.4", "32.4", "", "", "81.9", "71.8", "", "50.5", "", "2", "", "", "104", "1", "2", "165", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "84.0", "83.3", "", "", "", "", "83.5"]} -{"pcdb_id": 10627, "brand_name": "Sime", "model_name": "Format 110 C TS LPG", "model_qualifier": "", "winter_efficiency_pct": 83.1, "summer_efficiency_pct": 73.0, "comparative_hot_water_efficiency_pct": 51.3, "output_kw_max": 32.4, "final_year_of_manufacture": 2018, "raw": ["010627", "000213", "0", "2018/Feb/26 17:02", "Fonderie Sime S.p.A.", "Sime", "Format 110 C TS LPG", "", "", "2006", "2018", "2", "2", "1", "2", "0", "", "", "1", "3", "2", "32.4", "32.4", "", "", "83.1", "73.0", "", "51.3", "", "2", "1", "", "104", "1", "2", "165", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "85.8", "85.2", "", "", "", "", "85.3"]} -{"pcdb_id": 10628, "brand_name": "Sime", "model_name": "Format System 24TS", "model_qualifier": "", "winter_efficiency_pct": 81.5, "summer_efficiency_pct": 70.8, "comparative_hot_water_efficiency_pct": 51.7, "output_kw_max": 23.7, "final_year_of_manufacture": 2018, "raw": ["010628", "000213", "0", "2018/Feb/28 16:59", "Fonderie Sime S.p.A.", "Sime", "Format System 24TS", "", "", "2006", "2018", "1", "2", "1", "1", "0", "", "", "1", "3", "2", "23.7", "23.7", "", "", "81.5", "70.8", "", "51.7", "", "2", "", "", "102", "1", "2", "120", "10", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "83.9", "82.2", "", "", "", "", "82.5"]} -{"pcdb_id": 10629, "brand_name": "Sime", "model_name": "Format System 24TS LPG", "model_qualifier": "", "winter_efficiency_pct": 83.3, "summer_efficiency_pct": 72.6, "comparative_hot_water_efficiency_pct": 53.0, "output_kw_max": 23.7, "final_year_of_manufacture": 2018, "raw": ["010629", "000213", "0", "2018/Feb/28 17:00", "Fonderie Sime S.p.A.", "Sime", "Format System 24TS LPG", "", "", "2006", "2018", "2", "2", "1", "1", "0", "", "", "1", "3", "2", "23.7", "23.7", "", "", "83.3", "72.6", "", "53.0", "", "2", "1", "", "102", "1", "2", "120", "10", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "85.7", "84.0", "", "", "", "", "84.3"]} -{"pcdb_id": 10631, "brand_name": "Sime", "model_name": "Format System 30TS", "model_qualifier": "", "winter_efficiency_pct": 82.3, "summer_efficiency_pct": 71.6, "comparative_hot_water_efficiency_pct": 52.3, "output_kw_max": 28.0, "final_year_of_manufacture": 2018, "raw": ["010631", "000213", "0", "2018/Mar/05 14:05", "Fonderie Sime S.p.A.", "Sime", "Format System 30TS", "", "", "2006", "2018", "1", "2", "1", "1", "0", "", "", "1", "3", "2", "28.0", "28.0", "", "", "82.3", "71.6", "", "52.3", "", "2", "", "", "102", "1", "2", "120", "10", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "84.3", "83.6", "", "", "", "", "83.7"]} -{"pcdb_id": 10632, "brand_name": "Sime", "model_name": "Format System 30TS LPG", "model_qualifier": "", "winter_efficiency_pct": 83.3, "summer_efficiency_pct": 72.6, "comparative_hot_water_efficiency_pct": 53.0, "output_kw_max": 28.0, "final_year_of_manufacture": 2018, "raw": ["010632", "000213", "0", "2018/Mar/05 14:06", "Fonderie Sime S.p.A.", "Sime", "Format System 30TS LPG", "", "", "2006", "2018", "2", "2", "1", "1", "0", "", "", "1", "3", "2", "28.0", "28.0", "", "", "83.3", "72.6", "", "53.0", "", "2", "1", "", "102", "1", "2", "120", "10", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "86.2", "85.5", "", "", "", "", "85.6"]} -{"pcdb_id": 10633, "brand_name": "Sime", "model_name": "Format System 35TS", "model_qualifier": "", "winter_efficiency_pct": 82.1, "summer_efficiency_pct": 71.4, "comparative_hot_water_efficiency_pct": 52.2, "output_kw_max": 32.4, "final_year_of_manufacture": 2018, "raw": ["010633", "000213", "0", "2018/Mar/05 14:06", "Fonderie Sime S.p.A.", "Sime", "Format System 35TS", "", "", "2006", "2018", "1", "2", "1", "1", "0", "", "", "1", "3", "2", "32.4", "32.4", "", "", "82.1", "71.4", "", "52.2", "", "2", "", "", "102", "1", "2", "165", "10", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "84.0", "83.3", "", "", "", "", "83.5"]} -{"pcdb_id": 10634, "brand_name": "Sime", "model_name": "Format System 35TS LPG", "model_qualifier": "", "winter_efficiency_pct": 83.3, "summer_efficiency_pct": 72.6, "comparative_hot_water_efficiency_pct": 53.0, "output_kw_max": 32.4, "final_year_of_manufacture": 2018, "raw": ["010634", "000213", "0", "2018/Mar/05 14:07", "Fonderie Sime S.p.A.", "Sime", "Format System 35TS LPG", "", "", "2006", "2018", "2", "2", "1", "1", "0", "", "", "1", "3", "2", "32.4", "32.4", "", "", "83.3", "72.6", "", "53.0", "", "2", "1", "", "102", "1", "2", "165", "10", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "85.8", "85.2", "", "", "", "", "85.3"]} -{"pcdb_id": 10635, "brand_name": "Sime", "model_name": "FE-25HE UK/1 N", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 56.3, "output_kw_max": 22.7, "final_year_of_manufacture": 2018, "raw": ["010635", "000213", "0", "2018/Feb/26 16:51", "Fonderie Sime S.p.A.", "Sime", "FE-25HE UK/1 N", "", "", "2005", "2018", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "22.7", "22.7", "", "", "88.6", "80.0", "", "56.3", "", "2", "", "", "104", "1", "2", "50", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "98.4", "", "", "", "", "96.4"]} -{"pcdb_id": 10636, "brand_name": "Sime", "model_name": "FE-25HE UK/1 N", "model_qualifier": "", "winter_efficiency_pct": 89.6, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 57.0, "output_kw_max": 22.7, "final_year_of_manufacture": 2017, "raw": ["010636", "000213", "0", "2018/Feb/26 16:52", "Fonderie Sime S.p.A.", "Sime", "FE-25HE UK/1 N", "", "", "2005", "2017", "2", "2", "1", "2", "0", "", "", "2", "3", "2", "22.7", "22.7", "", "", "89.6", "81.0", "", "57.0", "", "2", "1", "", "104", "1", "2", "50", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "", "", "0005", "", "", "", "", "", "", "", "", "89.8", "100.6", "", "", "", "", "98.5"]} -{"pcdb_id": 10637, "brand_name": "Sime", "model_name": "FE-30HE UK/1 N", "model_qualifier": "", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 56.6, "output_kw_max": 27.3, "final_year_of_manufacture": 2018, "raw": ["010637", "000213", "0", "2018/Feb/26 16:53", "Fonderie Sime S.p.A.", "Sime", "FE-30HE UK/1 N", "", "", "2005", "2018", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "27.3", "27.3", "", "", "89.1", "80.5", "", "56.6", "", "2", "", "", "104", "1", "2", "50", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "", "", "0005", "", "", "", "", "", "", "", "", "88.2", "99.5", "", "", "", "", "97.3"]} -{"pcdb_id": 10638, "brand_name": "Sime", "model_name": "FE-30HE UK/1 N", "model_qualifier": "", "winter_efficiency_pct": 90.1, "summer_efficiency_pct": 81.5, "comparative_hot_water_efficiency_pct": 57.3, "output_kw_max": 27.3, "final_year_of_manufacture": 2018, "raw": ["010638", "000213", "0", "2018/Feb/26 16:54", "Fonderie Sime S.p.A.", "Sime", "FE-30HE UK/1 N", "", "", "2005", "2018", "2", "2", "1", "2", "0", "", "", "2", "3", "2", "27.3", "27.3", "", "", "90.1", "81.5", "", "57.3", "", "2", "1", "", "104", "1", "2", "50", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "", "", "0005", "", "", "", "", "", "", "", "", "90.2", "101.7", "", "", "", "", "99.5"]} -{"pcdb_id": 10639, "brand_name": "Alpha", "model_name": "CD24C", "model_qualifier": "", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 56.6, "output_kw_max": 23.6, "final_year_of_manufacture": 2007, "raw": ["010639", "000001", "0", "2011/Sep/06 13:09", "Alpha Therm", "Alpha", "CD24C", "", "", "2003", "2007", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "23.6", "23.6", "", "", "89.1", "80.5", "", "56.6", "", "2", "1", "", "104", "1", "2", "125", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "91.3", "98.5", "", "", "", "", "97.2"]} -{"pcdb_id": 10640, "brand_name": "Alpha", "model_name": "CD24S", "model_qualifier": "", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 23.6, "final_year_of_manufacture": 2007, "raw": ["010640", "000001", "0", "2012/Mar/27 10:12", "Alpha Therm", "Alpha", "CD24S", "", "", "2003", "2007", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "23.6", "23.6", "", "", "89.1", "80.1", "", "58.5", "", "2", "1", "", "102", "1", "2", "125", "2", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "91.3", "98.5", "", "", "", "", "97.2"]} -{"pcdb_id": 10641, "brand_name": "Alpha", "model_name": "CD32C", "model_qualifier": "", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 80.6, "comparative_hot_water_efficiency_pct": 56.7, "output_kw_max": 32.0, "final_year_of_manufacture": null, "raw": ["010641", "000001", "0", "2011/Sep/06 13:11", "Alpha Therm", "Alpha", "CD32C", "", "", "2003", "", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "32", "32", "", "", "89.2", "80.6", "", "56.7", "", "2", "1", "", "104", "1", "2", "140", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "91.1", "99.1", "", "", "", "", "97.6"]} -{"pcdb_id": 10642, "brand_name": "Alpha", "model_name": "CD50", "model_qualifier": "", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 82.0, "comparative_hot_water_efficiency_pct": 50.2, "output_kw_max": 32.0, "final_year_of_manufacture": null, "raw": ["010642", "000001", "0", "2024/Jan/31 10:17", "Alpha Therm", "Alpha", "CD50", "", "", "2004", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "32", "32", "", "", "89.2", "82.0", "", "50.2", "", "2", "1", "", "106", "1", "2", "140", "2", "2", "2", "0", "52", "0", "25", "5", "60", "0.97", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "91.1", "98.9", "", "", "", "", "97.4"]} -{"pcdb_id": 10643, "brand_name": "Broag Remeha", "model_name": "Avanta Plus", "model_qualifier": "35c", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 56.5, "output_kw_max": 29.5, "final_year_of_manufacture": null, "raw": ["010643", "000005", "0", "2012/Apr/11 14:49", "Remeha", "Broag Remeha", "Avanta Plus", "35c", "4767303", "2005", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "29.5", "29.5", "", "", "88.9", "80.3", "", "56.5", "", "2", "", "", "104", "1", "2", "115", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.5", "98.8", "", "", "", "", "96.9"]} -{"pcdb_id": 10644, "brand_name": "Gerkros", "model_name": "Gem fdc 80/105", "model_qualifier": "", "winter_efficiency_pct": 83.1, "summer_efficiency_pct": 71.4, "comparative_hot_water_efficiency_pct": 52.2, "output_kw_max": 30.77, "final_year_of_manufacture": null, "raw": ["010644", "000245", "0", "2012/Mar/27 10:12", "Gerkros Boilers (Tipperary) Limited", "Gerkros", "Gem fdc 80/105", "", "", "1988", "current", "4", "1", "1", "1", "0", "", "", "1", "3", "2", "23.45", "30.77", "", "", "83.1", "71.4", "", "52.2", "", "2", "", "", "201", "1", "1", "250", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "83.0", "83.2", "", "", "", "", "83.2"]} -{"pcdb_id": 10646, "brand_name": "Gerkros", "model_name": "Cozy Mann 80/105 fdc", "model_qualifier": "", "winter_efficiency_pct": 83.1, "summer_efficiency_pct": 71.4, "comparative_hot_water_efficiency_pct": 52.2, "output_kw_max": 30.77, "final_year_of_manufacture": null, "raw": ["010646", "000245", "0", "2012/Mar/27 10:12", "Gerkros Boilers (Tipperary) Limited", "Gerkros", "Cozy Mann 80/105 fdc", "", "", "1988", "current", "4", "1", "1", "1", "0", "", "", "1", "3", "2", "23.45", "30.77", "", "", "83.1", "71.4", "", "52.2", "", "2", "", "", "201", "1", "1", "250", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "83.0", "83.2", "", "", "", "", "83.2"]} -{"pcdb_id": 10647, "brand_name": "Gerkros", "model_name": "Gem fdc 50/70", "model_qualifier": "", "winter_efficiency_pct": 85.1, "summer_efficiency_pct": 73.4, "comparative_hot_water_efficiency_pct": 53.6, "output_kw_max": 20.51, "final_year_of_manufacture": null, "raw": ["010647", "000245", "0", "2012/Mar/27 10:12", "Gerkros Boilers (Tipperary) Limited", "Gerkros", "Gem fdc 50/70", "", "", "1988", "current", "4", "1", "1", "1", "0", "", "", "1", "3", "2", "14.65", "20.51", "", "", "85.1", "73.4", "", "53.6", "", "2", "", "", "201", "1", "1", "250", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "83.1", "92.9", "", "", "", "", "91.0"]} -{"pcdb_id": 10648, "brand_name": "Gerkros", "model_name": "Cozy Mann 50/70 fdc", "model_qualifier": "", "winter_efficiency_pct": 85.1, "summer_efficiency_pct": 73.4, "comparative_hot_water_efficiency_pct": 53.6, "output_kw_max": 20.51, "final_year_of_manufacture": null, "raw": ["010648", "000245", "0", "2012/Mar/27 10:12", "Gerkros Boilers (Tipperary) Limited", "Gerkros", "Cozy Mann 50/70 fdc", "", "", "1988", "current", "4", "1", "1", "1", "0", "", "", "1", "3", "2", "14.65", "20.51", "", "", "85.1", "73.4", "", "53.6", "", "2", "", "", "201", "1", "1", "250", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "83.1", "92.9", "", "", "", "", "91.0"]} -{"pcdb_id": 10649, "brand_name": "Gerkros", "model_name": "Gem Top Cleaner 60/95", "model_qualifier": "", "winter_efficiency_pct": 83.6, "summer_efficiency_pct": 71.9, "comparative_hot_water_efficiency_pct": 52.5, "output_kw_max": 27.84, "final_year_of_manufacture": null, "raw": ["010649", "000245", "0", "2012/Mar/27 10:12", "Gerkros Boilers (Tipperary) Limited", "Gerkros", "Gem Top Cleaner 60/95", "", "", "1988", "current", "4", "1", "1", "1", "0", "", "", "1", "3", "2", "17.58", "27.84", "", "", "83.6", "71.9", "", "52.5", "", "2", "", "", "201", "1", "1", "250", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "84.3", "82.9", "", "", "", "", "83.2"]} -{"pcdb_id": 10650, "brand_name": "Gerkros", "model_name": "Gem Top Cleaner 90/120", "model_qualifier": "", "winter_efficiency_pct": 83.2, "summer_efficiency_pct": 71.5, "comparative_hot_water_efficiency_pct": 52.2, "output_kw_max": 35.17, "final_year_of_manufacture": null, "raw": ["010650", "000245", "0", "2012/Mar/27 10:12", "Gerkros Boilers (Tipperary) Limited", "Gerkros", "Gem Top Cleaner 90/120", "", "", "1988", "current", "4", "1", "1", "1", "0", "", "", "1", "3", "2", "26.38", "35.17", "", "", "83.2", "71.5", "", "52.2", "", "2", "", "", "201", "1", "1", "250", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "83.4", "82.9", "", "", "", "", "83.0"]} -{"pcdb_id": 10651, "brand_name": "Gerkros", "model_name": "Gem Superior id 90/120", "model_qualifier": "", "winter_efficiency_pct": 83.2, "summer_efficiency_pct": 71.5, "comparative_hot_water_efficiency_pct": 52.2, "output_kw_max": 35.17, "final_year_of_manufacture": null, "raw": ["010651", "000245", "0", "2012/Mar/27 10:12", "Gerkros Boilers (Tipperary) Limited", "Gerkros", "Gem Superior id 90/120", "", "", "1988", "current", "4", "1", "1", "1", "0", "", "", "1", "3", "2", "26.38", "35.17", "", "", "83.2", "71.5", "", "52.2", "", "2", "", "", "201", "1", "1", "250", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "83.4", "82.9", "", "", "", "", "83.0"]} -{"pcdb_id": 10652, "brand_name": "Gerkros", "model_name": "Cozy Mann 90/120 tdc", "model_qualifier": "", "winter_efficiency_pct": 83.2, "summer_efficiency_pct": 71.5, "comparative_hot_water_efficiency_pct": 52.2, "output_kw_max": 35.17, "final_year_of_manufacture": null, "raw": ["010652", "000245", "0", "2012/Mar/27 10:12", "Gerkros Boilers (Tipperary) Limited", "Gerkros", "Cozy Mann 90/120 tdc", "", "", "1988", "current", "4", "1", "1", "1", "0", "", "", "1", "3", "2", "26.38", "35.17", "", "", "83.2", "71.5", "", "52.2", "", "2", "", "", "201", "1", "1", "250", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "83.4", "82.9", "", "", "", "", "83.0"]} -{"pcdb_id": 10653, "brand_name": "Gerkros", "model_name": "Cozy Mann 60/95 tdc", "model_qualifier": "", "winter_efficiency_pct": 83.6, "summer_efficiency_pct": 71.9, "comparative_hot_water_efficiency_pct": 52.5, "output_kw_max": 27.84, "final_year_of_manufacture": null, "raw": ["010653", "000245", "0", "2012/Mar/27 10:12", "Gerkros Boilers (Tipperary) Limited", "Gerkros", "Cozy Mann 60/95 tdc", "", "", "1988", "current", "4", "1", "1", "1", "0", "", "", "1", "3", "2", "17.58", "27.84", "", "", "83.6", "71.9", "", "52.5", "", "2", "", "", "201", "1", "1", "250", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "84.3", "82.9", "", "", "", "", "83.2"]} -{"pcdb_id": 15001, "brand_name": "Mikrofill", "model_name": "Ethos", "model_qualifier": "36C", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 56.0, "output_kw_max": 27.6, "final_year_of_manufacture": null, "raw": ["015001", "000226", "0", "2006/Apr/26 11:15", "Mikrofill Systems", "Mikrofill", "Ethos", "36C", "", "2005", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "27.6", "27.6", "", "", "88.3", "79.7", "", "56.0", "", "2", "", "", "104", "1", "2", "180", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.1", "97.4", "", "", "", "", "95.6"]} -{"pcdb_id": 15002, "brand_name": "Mikrofill", "model_name": "Ethos", "model_qualifier": "54C", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 56.1, "output_kw_max": 37.5, "final_year_of_manufacture": null, "raw": ["015002", "000226", "0", "2006/Apr/26 11:15", "Mikrofill Systems", "Mikrofill", "Ethos", "54C", "", "2005", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "37.5", "37.5", "", "", "88.4", "79.8", "", "56.1", "", "2", "", "", "104", "1", "2", "200", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "97.8", "", "", "", "", "96.0"]} -{"pcdb_id": 15007, "brand_name": "Ideal", "model_name": "Icos", "model_qualifier": "HE30", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 30.1, "final_year_of_manufacture": 2011, "raw": ["015007", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "Icos", "HE30", "41-399-10", "2006", "2011", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "30.1", "30.1", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "42", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.0", "97.5", "", "", "", "", "95.9"]} -{"pcdb_id": 15008, "brand_name": "Ideal", "model_name": "Icos", "model_qualifier": "HE36", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 37.0, "final_year_of_manufacture": 2011, "raw": ["015008", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "Icos", "HE36", "41-399-16", "2006", "2011", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "37", "37", "", "", "88.9", "79.9", "", "58.3", "", "2", "", "", "102", "1", "2", "42", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.9", "98.6", "", "", "", "", "96.7"]} -{"pcdb_id": 15009, "brand_name": "Elco", "model_name": "Trigon 22", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 20.1, "final_year_of_manufacture": null, "raw": ["015009", "000237", "0", "2012/Mar/27 10:12", "ELCO Klöckner Heiztechnik", "Elco", "Trigon 22", "", "", "2003", "current", "1", "1", "1", "1", "0", "", "", "2", "2", "2", "20.1", "20.1", "", "", "88.1", "79.1", "", "57.8", "", "2", "", "", "102", "1", "2", "137", "102", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.6", "97.3", "", "", "", "", "95.5"]} -{"pcdb_id": 15010, "brand_name": "Grant", "model_name": "Vortex", "model_qualifier": "15-26S Kitchen Boiler", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 81.3, "comparative_hot_water_efficiency_pct": 59.4, "output_kw_max": 26.0, "final_year_of_manufacture": null, "raw": ["015010", "000048", "0", "2012/Mar/27 10:12", "Grant Engineering (UK)", "Grant", "Vortex", "15-26S Kitchen Boiler", "", "2002", "current", "4", "1", "1", "1", "0", "", "", "2", "2", "2", "15", "26", "", "", "89.1", "81.3", "", "59.4", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "93.6", "96.4", "", "", "", "", "95.9"]} -{"pcdb_id": 15011, "brand_name": "Grant", "model_name": "Vortex", "model_qualifier": "26-36 Utility Boiler", "winter_efficiency_pct": 90.5, "summer_efficiency_pct": 82.7, "comparative_hot_water_efficiency_pct": 60.4, "output_kw_max": 36.0, "final_year_of_manufacture": null, "raw": ["015011", "000048", "0", "2012/Mar/27 10:12", "Grant Engineering (UK)", "Grant", "Vortex", "26-36 Utility Boiler", "", "2003", "current", "4", "1", "1", "1", "0", "", "", "2", "2", "2", "26", "36", "", "", "90.5", "82.7", "", "60.4", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "95.1", "99.3", "", "", "", "", "98.5"]} -{"pcdb_id": 15012, "brand_name": "Grant", "model_name": "Vortex", "model_qualifier": "26-36-S Utility System Boiler", "winter_efficiency_pct": 90.5, "summer_efficiency_pct": 82.7, "comparative_hot_water_efficiency_pct": 60.4, "output_kw_max": 36.0, "final_year_of_manufacture": null, "raw": ["015012", "000048", "0", "2012/Mar/27 10:12", "Grant Engineering (UK)", "Grant", "Vortex", "26-36-S Utility System Boiler", "", "2003", "current", "4", "1", "1", "1", "0", "", "", "2", "2", "2", "26", "36", "", "", "90.5", "82.7", "", "60.4", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "95.1", "99.3", "", "", "", "", "98.5"]} -{"pcdb_id": 15013, "brand_name": "Grant", "model_name": "Vortex", "model_qualifier": "15-26 Kitchen Boiler", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 81.3, "comparative_hot_water_efficiency_pct": 59.4, "output_kw_max": 26.0, "final_year_of_manufacture": null, "raw": ["015013", "000048", "0", "2012/Mar/27 10:12", "Grant Engineering (UK)", "Grant", "Vortex", "15-26 Kitchen Boiler", "", "2002", "current", "4", "1", "1", "1", "0", "", "", "2", "2", "2", "15", "26", "", "", "89.1", "81.3", "", "59.4", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "93.6", "96.4", "", "", "", "", "95.9"]} -{"pcdb_id": 15014, "brand_name": "Elco", "model_name": "Straton 22", "model_qualifier": "", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 21.5, "final_year_of_manufacture": null, "raw": ["015014", "000237", "0", "2012/Mar/27 10:12", "ELCO Klöckner Heiztechnik", "Elco", "Straton 22", "", "", "1997", "current", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "12.1", "21.5", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "190", "2.5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "93.7", "98.4", "", "", "", "", "97.5"]} -{"pcdb_id": 15015, "brand_name": "Elco", "model_name": "Systron 2-22", "model_qualifier": "", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 22.0, "final_year_of_manufacture": null, "raw": ["015015", "000237", "0", "2012/Mar/27 10:12", "ELCO Klöckner Heiztechnik", "Elco", "Systron 2-22", "", "", "1997", "current", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "15", "22", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "189", "2.5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "88.3", "89.2", "", "", "", "", "89.0"]} -{"pcdb_id": 15016, "brand_name": "Glow-worm", "model_name": "Flexicom 12hx", "model_qualifier": "", "winter_efficiency_pct": 87.8, "summer_efficiency_pct": 78.8, "comparative_hot_water_efficiency_pct": 57.6, "output_kw_max": 12.0, "final_year_of_manufacture": null, "raw": ["015016", "000207", "0", "2012/Mar/27 10:12", "Vaillant Group", "Glow-worm", "Flexicom 12hx", "", "GC 41-315-28", "2006", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "12.0", "12.0", "", "", "87.8", "78.8", "", "57.6", "", "2", "", "", "102", "1", "2", "60", "6", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0085", "", "", "", "", "", "", "", "", "89.6", "95.7", "", "", "", "", "94.5"]} -{"pcdb_id": 15017, "brand_name": "Glow-worm", "model_name": "Flexicom 15hx", "model_qualifier": "", "winter_efficiency_pct": 87.8, "summer_efficiency_pct": 78.8, "comparative_hot_water_efficiency_pct": 57.6, "output_kw_max": 15.0, "final_year_of_manufacture": null, "raw": ["015017", "000207", "0", "2012/Mar/27 10:12", "Vaillant Group", "Glow-worm", "Flexicom 15hx", "", "GC 41-315-29", "2006", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "15.0", "15.0", "", "", "87.8", "78.8", "", "57.6", "", "2", "", "", "102", "1", "2", "60", "6", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.4", "95.7", "", "", "", "", "94.5"]} -{"pcdb_id": 15018, "brand_name": "Glow-worm", "model_name": "Flexicom 18hx", "model_qualifier": "", "winter_efficiency_pct": 87.7, "summer_efficiency_pct": 78.7, "comparative_hot_water_efficiency_pct": 57.5, "output_kw_max": 18.0, "final_year_of_manufacture": null, "raw": ["015018", "000207", "0", "2012/Mar/27 10:12", "Vaillant Group", "Glow-worm", "Flexicom 18hx", "", "GC 41-315-42", "2006", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18.0", "18.0", "", "", "87.7", "78.7", "", "57.5", "", "2", "", "", "102", "1", "2", "60", "6", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0085", "", "", "", "", "", "", "", "", "89.0", "95.7", "", "", "", "", "94.4"]} -{"pcdb_id": 15019, "brand_name": "Glow-worm", "model_name": "Flexicom 24hx", "model_qualifier": "", "winter_efficiency_pct": 87.7, "summer_efficiency_pct": 78.7, "comparative_hot_water_efficiency_pct": 57.5, "output_kw_max": 24.0, "final_year_of_manufacture": null, "raw": ["015019", "000207", "0", "2012/Mar/27 10:12", "Vaillant Group", "Glow-worm", "Flexicom 24hx", "", "GC 41-315-61", "2006", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24.0", "24.0", "", "", "87.7", "78.7", "", "57.5", "", "2", "", "", "102", "1", "2", "60", "6", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0085", "", "", "", "", "", "", "", "", "88.8", "95.7", "", "", "", "", "94.4"]} -{"pcdb_id": 15020, "brand_name": "Glow-worm", "model_name": "Flexicom 30hx", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 30.0, "final_year_of_manufacture": null, "raw": ["015020", "000207", "0", "2012/Mar/27 10:12", "Vaillant Group", "Glow-worm", "Flexicom 30hx", "", "GC 41-315-67", "2006", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "30.0", "30.0", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "60", "6", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0085", "", "", "", "", "", "", "", "", "87.7", "97.0", "", "", "", "", "95.3"]} -{"pcdb_id": 15021, "brand_name": "Glow-worm", "model_name": "Flexicom 18sx", "model_qualifier": "", "winter_efficiency_pct": 87.7, "summer_efficiency_pct": 78.7, "comparative_hot_water_efficiency_pct": 57.5, "output_kw_max": 18.0, "final_year_of_manufacture": null, "raw": ["015021", "000207", "0", "2012/Mar/27 10:12", "Vaillant Group", "Glow-worm", "Flexicom 18sx", "", "GC 41-315-72", "2006", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18.0", "18.0", "", "", "87.7", "78.7", "", "57.5", "", "2", "", "", "102", "1", "2", "180", "6", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.9", "95.7", "", "", "", "", "94.4"]} -{"pcdb_id": 15022, "brand_name": "Glow-worm", "model_name": "Flexicom 30sx", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 30.0, "final_year_of_manufacture": null, "raw": ["015022", "000207", "0", "2012/Mar/27 10:12", "Vaillant Group", "Glow-worm", "Flexicom 30sx", "", "GC 41-047-76", "2006", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "30.0", "30.0", "", "", "88.1", "79.1", "", "57.8", "", "2", "", "", "102", "1", "2", "180", "6", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "97.0", "", "", "", "", "95.3"]} -{"pcdb_id": 15023, "brand_name": "Glow-worm", "model_name": "Flexicom 24cx", "model_qualifier": "", "winter_efficiency_pct": 87.8, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 55.7, "output_kw_max": 18.0, "final_year_of_manufacture": null, "raw": ["015023", "000207", "0", "2010/Oct/22 10:39", "Vaillant Group", "Glow-worm", "Flexicom 24cx", "", "GC 47-047-33", "2006", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "18.0", "18.0", "", "", "87.8", "79.2", "", "55.7", "", "2", "", "", "104", "1", "2", "180", "6", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0085", "", "", "", "", "", "", "", "", "88.7", "96.0", "", "", "", "", "94.7"]} -{"pcdb_id": 15024, "brand_name": "Glow-worm", "model_name": "Flexicom 30cx", "model_qualifier": "", "winter_efficiency_pct": 87.7, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 55.7, "output_kw_max": 24.0, "final_year_of_manufacture": null, "raw": ["015024", "000207", "0", "2010/Oct/22 10:40", "Vaillant Group", "Glow-worm", "Flexicom 30cx", "", "GC 47-047-34", "2006", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.0", "24.0", "", "", "87.7", "79.1", "", "55.7", "", "2", "", "", "104", "1", "2", "180", "6", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0085", "", "", "", "", "", "", "", "", "88.2", "96.0", "", "", "", "", "94.6"]} -{"pcdb_id": 15025, "brand_name": "Gerkros", "model_name": "Termogas KT/A", "model_qualifier": "", "winter_efficiency_pct": 87.7, "summer_efficiency_pct": 78.7, "comparative_hot_water_efficiency_pct": 57.5, "output_kw_max": 21.9, "final_year_of_manufacture": null, "raw": ["015025", "000245", "0", "2012/Mar/27 10:12", "Gerkros Boilers (Tipperary) Limited", "Gerkros", "Termogas KT/A", "", "", "2005", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "1", "21.9", "21.9", "", "", "87.7", "78.7", "", "57.5", "", "2", "", "", "102", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "96.1", "", "", "", "", "94.6"]} -{"pcdb_id": 15027, "brand_name": "Baxi", "model_name": "Megaflo System", "model_qualifier": "24 HE", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 24.0, "final_year_of_manufacture": 2008, "raw": ["015027", "000005", "0", "2012/Mar/27 10:12", "Baxi Heating", "Baxi", "Megaflo System", "24 HE", "GC No. 47-075-47", "2006", "2008", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24.0", "24.0", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "150", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "96.9", "", "", "", "", "95.2"]} -{"pcdb_id": 15028, "brand_name": "Baxi", "model_name": "Megaflo System", "model_qualifier": "28 HE", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 78.9, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 28.0, "final_year_of_manufacture": 2008, "raw": ["015028", "000005", "0", "2012/Mar/27 10:12", "Baxi Heating", "Baxi", "Megaflo System", "28 HE", "GC No. 47-075-48", "2006", "2008", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "28.0", "28.0", "", "", "87.9", "78.9", "", "57.7", "", "2", "", "", "102", "1", "2", "150", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "96.7", "", "", "", "", "95.0"]} -{"pcdb_id": 15029, "brand_name": "Baxi", "model_name": "Duo-tec Combi", "model_qualifier": "24 HE", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 55.8, "output_kw_max": 24.0, "final_year_of_manufacture": 2008, "raw": ["015029", "000005", "0", "2010/Nov/19 09:05", "Baxi Heating", "Baxi", "Duo-tec Combi", "24 HE", "GC No. 47-075-23", "2006", "2008", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.0", "24.0", "", "", "88.0", "79.4", "", "55.8", "", "2", "", "", "104", "1", "2", "155", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "96.9", "", "", "", "", "95.2"]} -{"pcdb_id": 15030, "brand_name": "Baxi", "model_name": "Duo-tec Combi", "model_qualifier": "28 HE", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 55.8, "output_kw_max": 24.0, "final_year_of_manufacture": 2008, "raw": ["015030", "000005", "0", "2010/Nov/19 09:05", "Baxi Heating", "Baxi", "Duo-tec Combi", "28 HE", "GC No. 47-075-25", "2006", "2008", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.0", "24.0", "", "", "88.0", "79.4", "", "55.8", "", "2", "", "", "104", "1", "2", "155", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "96.9", "", "", "", "", "95.2"]} -{"pcdb_id": 15031, "brand_name": "Baxi", "model_name": "Duo-tec Combi", "model_qualifier": "33 HE", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 55.8, "output_kw_max": 28.0, "final_year_of_manufacture": 2008, "raw": ["015031", "000005", "0", "2010/Nov/19 09:05", "Baxi Heating", "Baxi", "Duo-tec Combi", "33 HE", "GC No. 47-075-24", "2006", "2008", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28.0", "28.0", "", "", "87.9", "79.3", "", "55.8", "", "2", "", "", "104", "1", "2", "160", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "96.7", "", "", "", "", "95.0"]} -{"pcdb_id": 15032, "brand_name": "Baxi", "model_name": "Solo", "model_qualifier": "15 HE", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 15.24, "final_year_of_manufacture": 2010, "raw": ["015032", "000005", "0", "2020/Dec/07 11:55", "Baxi Heating", "Baxi", "Solo", "15 HE", "GC No. 41-075-46", "2006", "2010", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "15.24", "15.24", "", "", "88.7", "79.7", "", "58.2", "", "2", "", "", "102", "1", "2", "80", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.3", "97.7", "", "", "", "", "96.3"]} -{"pcdb_id": 15033, "brand_name": "Baxi", "model_name": "Solo", "model_qualifier": "24 HE", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 22.0, "final_year_of_manufacture": 2010, "raw": ["015033", "000005", "0", "2020/Dec/07 11:56", "Baxi Heating", "Baxi", "Solo", "24 HE", "GC No. 41-075-45", "2006", "2010", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "22.0", "22.0", "", "", "88.1", "79.1", "", "57.8", "", "2", "", "", "102", "1", "2", "80", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.5", "96.5", "", "", "", "", "95.2"]} -{"pcdb_id": 15034, "brand_name": "Baxi", "model_name": "Solo", "model_qualifier": "30 HE", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 30.18, "final_year_of_manufacture": 2010, "raw": ["015034", "000005", "0", "2020/Dec/07 12:08", "Baxi Heating", "Baxi", "Solo", "30 HE", "GC No. 41-075-44", "2006", "2010", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "30.18", "30.18", "", "", "88.1", "79.1", "", "57.8", "", "2", "", "", "102", "1", "2", "80", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.4", "96.4", "", "", "", "", "95.1"]} -{"pcdb_id": 15035, "brand_name": "ATAG", "model_name": "Q25C", "model_qualifier": "", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 56.3, "output_kw_max": 21.9, "final_year_of_manufacture": null, "raw": ["015035", "000227", "0", "2013/Oct/23 12:56", "ATAG Verwarming Nederland BV", "ATAG", "Q25C", "", "", "2006", "current", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "21.9", "21.9", "", "", "88.7", "80.1", "", "56.3", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.1", "98.6", "", "", "", "", "96.6"]} -{"pcdb_id": 15036, "brand_name": "ATAG", "model_name": "Q38C", "model_qualifier": "", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 56.4, "output_kw_max": 33.3, "final_year_of_manufacture": null, "raw": ["015036", "000227", "0", "2013/Oct/23 12:57", "ATAG Verwarming Nederland BV", "ATAG", "Q38C", "", "", "2006", "current", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "33.3", "33.3", "", "", "88.7", "80.1", "", "56.4", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "98.7", "", "", "", "", "96.7"]} -{"pcdb_id": 15037, "brand_name": "ATAG", "model_name": "Q51C", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 56.4, "output_kw_max": 44.7, "final_year_of_manufacture": null, "raw": ["015037", "000227", "0", "2013/Oct/23 12:57", "ATAG Verwarming Nederland BV", "ATAG", "Q51C", "", "", "2006", "current", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "44.7", "44.7", "", "", "88.8", "80.2", "", "56.4", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "98.8", "", "", "", "", "96.8"]} -{"pcdb_id": 15038, "brand_name": "ATAG", "model_name": "Q25S", "model_qualifier": "", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 21.9, "final_year_of_manufacture": null, "raw": ["015038", "000227", "0", "2013/Oct/23 12:57", "ATAG Verwarming Nederland BV", "ATAG", "Q25S", "", "", "2006", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "21.9", "21.9", "", "", "88.9", "79.9", "", "58.3", "", "2", "", "", "102", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.2", "98.9", "", "", "", "", "96.9"]} -{"pcdb_id": 15039, "brand_name": "ATAG", "model_name": "Q38S", "model_qualifier": "", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 33.3, "final_year_of_manufacture": null, "raw": ["015039", "000227", "0", "2013/Oct/23 12:57", "ATAG Verwarming Nederland BV", "ATAG", "Q38S", "", "", "2006", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "33.3", "33.3", "", "", "88.7", "79.7", "", "58.3", "", "2", "", "", "102", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "98.7", "", "", "", "", "96.7"]} -{"pcdb_id": 15040, "brand_name": "ATAG", "model_name": "Q51S", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 44.7, "final_year_of_manufacture": null, "raw": ["015040", "000227", "0", "2013/Oct/23 12:57", "ATAG Verwarming Nederland BV", "ATAG", "Q51S", "", "", "2006", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "44.7", "44.7", "", "", "88.8", "79.8", "", "58.3", "", "2", "", "", "102", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "98.8", "", "", "", "", "96.8"]} -{"pcdb_id": 15041, "brand_name": "ATAG", "model_name": "Q60S", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 52.5, "final_year_of_manufacture": null, "raw": ["015041", "000227", "0", "2013/Oct/23 12:57", "ATAG Verwarming Nederland BV", "ATAG", "Q60S", "", "", "2006", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "52.5", "52.5", "", "", "88.8", "79.8", "", "58.3", "", "2", "", "", "102", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "98.8", "", "", "", "", "96.8"]} -{"pcdb_id": 15042, "brand_name": "Halstead", "model_name": "Club HE 18", "model_qualifier": "", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 18.0, "final_year_of_manufacture": null, "raw": ["015042", "000019", "0", "2012/Mar/27 10:12", "Halstead Boilers", "Halstead", "Club HE 18", "", "GC No 41-260-20", "2006", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "18", "18", "", "", "88.2", "79.2", "", "57.8", "", "2", "", "", "102", "1", "2", "106", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "97.2", "", "", "", "", "95.5"]} -{"pcdb_id": 15043, "brand_name": "Alpha", "model_name": "CD13R", "model_qualifier": "", "winter_efficiency_pct": 87.8, "summer_efficiency_pct": 78.8, "comparative_hot_water_efficiency_pct": 57.6, "output_kw_max": 12.0, "final_year_of_manufacture": null, "raw": ["015043", "000001", "0", "2012/Mar/27 10:12", "Alpha Therm", "Alpha", "CD13R", "", "", "2005", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "12.0", "12.0", "", "", "87.8", "78.8", "", "57.6", "", "2", "", "", "102", "1", "2", "55", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "96.4", "", "", "", "", "94.8"]} -{"pcdb_id": 15046, "brand_name": "Alpha", "model_name": "CD30S", "model_qualifier": "", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 78.9, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 27.6, "final_year_of_manufacture": 2007, "raw": ["015046", "000001", "0", "2012/Mar/27 10:12", "Alpha Therm", "Alpha", "CD30S", "", "", "2005", "2007", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "27.6", "27.6", "", "", "87.9", "78.9", "", "57.7", "", "2", "", "", "102", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.5", "96.4", "", "", "", "", "94.9"]} -{"pcdb_id": 15048, "brand_name": "Alpha", "model_name": "CD13R", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 12.0, "final_year_of_manufacture": null, "raw": ["015048", "000001", "0", "2012/Mar/27 10:12", "Alpha Therm", "Alpha", "CD13R", "", "", "2005", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "12.0", "12.0", "", "", "88.8", "79.8", "", "58.3", "", "2", "1", "", "102", "1", "2", "55", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.7", "98.5", "", "", "", "", "96.9"]} -{"pcdb_id": 15049, "brand_name": "Alpha", "model_name": "CD24R", "model_qualifier": "", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 78.9, "comparative_hot_water_efficiency_pct": 57.6, "output_kw_max": 23.5, "final_year_of_manufacture": null, "raw": ["015049", "000001", "0", "2012/Mar/27 10:12", "Alpha Therm", "Alpha", "CD24R", "", "", "2005", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "23.5", "23.5", "", "", "87.9", "78.9", "", "57.6", "", "2", "", "", "102", "1", "2", "55", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.2", "96.4", "", "", "", "", "94.8"]} -{"pcdb_id": 15050, "brand_name": "Alpha", "model_name": "CD24R", "model_qualifier": "", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 23.5, "final_year_of_manufacture": null, "raw": ["015050", "000001", "0", "2012/Mar/27 10:12", "Alpha Therm", "Alpha", "CD24R", "", "", "2005", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "23.5", "23.5", "", "", "88.9", "79.9", "", "58.3", "", "2", "1", "", "102", "1", "2", "55", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.2", "98.5", "", "", "", "", "97.0"]} -{"pcdb_id": 15051, "brand_name": "Rotex", "model_name": "A1 BO 35i", "model_qualifier": "", "winter_efficiency_pct": 87.5, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 35.0, "final_year_of_manufacture": null, "raw": ["015051", "000246", "0", "2013/Sep/19 14:23", "Rotex Heating Systems", "Rotex", "A1 BO 35i", "", "", "1998", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "25", "35", "", "", "87.5", "79.7", "", "58.2", "", "2", "", "", "201", "1", "1", "250", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.3", "93.7", "", "", "", "", "93.1"]} -{"pcdb_id": 15052, "brand_name": "Rotex", "model_name": "GCU 25", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 37.7, "output_kw_max": 25.0, "final_year_of_manufacture": null, "raw": ["015052", "000246", "0", "2024/Jan/31 10:17", "Rotex Heating Systems", "Rotex", "GCU 25", "", "", "2005", "current", "1", "1", "1", "2", "0", "", "", "2", "3", "2", "25", "25", "", "", "88.1", "80.8", "", "37.7", "", "2", "", "", "106", "1", "2", "45", "7.7", "2", "1", "0", "500", "0", "80", "2", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "97.0", "", "", "", "", "95.4"]} -{"pcdb_id": 15053, "brand_name": "Rotex", "model_name": "GCU 25 F", "model_qualifier": "", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 81.9, "comparative_hot_water_efficiency_pct": 38.2, "output_kw_max": 25.0, "final_year_of_manufacture": null, "raw": ["015053", "000246", "0", "2024/Jan/31 10:17", "Rotex Heating Systems", "Rotex", "GCU 25 F", "", "", "2005", "current", "2", "1", "1", "2", "0", "", "", "2", "3", "2", "25", "25", "", "", "89.2", "81.9", "", "38.2", "", "2", "0", "", "106", "1", "2", "45", "7.7", "2", "1", "0", "500", "0", "80", "2", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.7", "97.4", "", "", "", "", "95.8"]} -{"pcdb_id": 15054, "brand_name": "Rotex", "model_name": "GCU 35", "model_qualifier": "", "winter_efficiency_pct": 87.7, "summer_efficiency_pct": 80.4, "comparative_hot_water_efficiency_pct": 37.6, "output_kw_max": 35.0, "final_year_of_manufacture": null, "raw": ["015054", "000246", "0", "2024/Jan/31 10:17", "Rotex Heating Systems", "Rotex", "GCU 35", "", "", "2005", "current", "1", "1", "1", "2", "0", "", "", "2", "3", "2", "35", "35", "", "", "87.7", "80.4", "", "37.6", "", "2", "", "", "106", "1", "2", "45", "7.7", "2", "1", "0", "500", "0", "80", "2", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "0", "", "0005", "", "", "", "", "", "", "", "", "86.9", "96.6", "", "", "", "", "94.7"]} -{"pcdb_id": 15055, "brand_name": "Rotex", "model_name": "GCU 35 F", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 81.2, "comparative_hot_water_efficiency_pct": 37.9, "output_kw_max": 35.0, "final_year_of_manufacture": null, "raw": ["015055", "000246", "0", "2024/Jan/31 10:17", "Rotex Heating Systems", "Rotex", "GCU 35 F", "", "", "2005", "current", "2", "1", "1", "2", "0", "", "", "2", "3", "2", "35", "35", "", "", "88.5", "81.2", "", "37.9", "", "2", "0", "", "106", "1", "2", "45", "7.7", "2", "1", "0", "500", "0", "80", "2", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "0", "", "0005", "", "", "", "", "", "", "", "", "87.2", "97.0", "", "", "", "", "95.1"]} -{"pcdb_id": 15056, "brand_name": "Rotex", "model_name": "GSU 25", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 37.7, "output_kw_max": 25.0, "final_year_of_manufacture": null, "raw": ["015056", "000246", "0", "2024/Jan/31 10:17", "Rotex Heating Systems", "Rotex", "GSU 25", "", "", "2005", "current", "1", "1", "1", "2", "0", "", "", "2", "3", "2", "25", "25", "", "", "88.1", "80.8", "", "37.7", "", "2", "", "", "106", "1", "2", "45", "7.7", "2", "1", "0", "500", "0", "80", "2", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "97.0", "", "", "", "", "95.4"]} -{"pcdb_id": 15057, "brand_name": "Rotex", "model_name": "GSU 25 F", "model_qualifier": "", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 81.9, "comparative_hot_water_efficiency_pct": 38.2, "output_kw_max": 25.0, "final_year_of_manufacture": null, "raw": ["015057", "000246", "0", "2024/Jan/31 10:17", "Rotex Heating Systems", "Rotex", "GSU 25 F", "", "", "2005", "current", "2", "1", "1", "2", "0", "", "", "2", "3", "2", "25", "25", "", "", "89.2", "81.9", "", "38.2", "", "2", "0", "", "106", "1", "2", "45", "7.7", "2", "1", "0", "500", "0", "80", "2", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "0", "", "0005", "", "", "", "", "", "", "", "", "88.7", "97.4", "", "", "", "", "95.8"]} -{"pcdb_id": 15058, "brand_name": "Rotex", "model_name": "GSU 35", "model_qualifier": "", "winter_efficiency_pct": 87.7, "summer_efficiency_pct": 80.4, "comparative_hot_water_efficiency_pct": 37.6, "output_kw_max": 35.0, "final_year_of_manufacture": null, "raw": ["015058", "000246", "0", "2024/Jan/31 10:17", "Rotex Heating Systems", "Rotex", "GSU 35", "", "", "2005", "current", "1", "1", "1", "2", "0", "", "", "2", "3", "2", "35", "35", "", "", "87.7", "80.4", "", "37.6", "", "2", "", "", "106", "1", "2", "45", "7.7", "2", "1", "0", "500", "0", "80", "2", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "0", "", "0005", "", "", "", "", "", "", "", "", "86.9", "96.6", "", "", "", "", "94.7"]} -{"pcdb_id": 15059, "brand_name": "Rotex", "model_name": "GSU 35 F", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 81.2, "comparative_hot_water_efficiency_pct": 37.9, "output_kw_max": 35.0, "final_year_of_manufacture": null, "raw": ["015059", "000246", "0", "2024/Jan/31 10:17", "Rotex Heating Systems", "Rotex", "GSU 35 F", "", "", "2005", "current", "2", "1", "1", "2", "0", "", "", "2", "3", "2", "35", "35", "", "", "88.5", "81.2", "", "37.9", "", "2", "0", "", "106", "1", "2", "45", "7.7", "2", "1", "0", "500", "0", "80", "2", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.2", "97.0", "", "", "", "", "95.1"]} -{"pcdb_id": 15060, "brand_name": "SARIgas", "model_name": "EcoTop", "model_qualifier": "ETF 28A", "winter_efficiency_pct": 85.6, "summer_efficiency_pct": 77.0, "comparative_hot_water_efficiency_pct": 54.1, "output_kw_max": 26.9, "final_year_of_manufacture": null, "raw": ["015060", "000244", "0", "2006/Jul/31 12:50", "SARIgas", "SARIgas", "EcoTop", "ETF 28A", "", "2006", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "26.9", "26.9", "", "", "85.6", "77.0", "", "54.1", "", "2", "", "", "104", "1", "2", "130", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "86.7", "91.2", "", "", "", "", "90.3"]} -{"pcdb_id": 15061, "brand_name": "SARIgas", "model_name": "EcoTop", "model_qualifier": "ETF 28A MA", "winter_efficiency_pct": 85.6, "summer_efficiency_pct": 77.0, "comparative_hot_water_efficiency_pct": 54.1, "output_kw_max": 26.9, "final_year_of_manufacture": null, "raw": ["015061", "000244", "0", "2006/Jul/31 12:50", "SARIgas", "SARIgas", "EcoTop", "ETF 28A MA", "", "2006", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "26.9", "26.9", "", "", "85.6", "77.0", "", "54.1", "", "2", "", "", "104", "1", "2", "130", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "86.7", "91.2", "", "", "", "", "90.3"]} -{"pcdb_id": 15062, "brand_name": "Potterton", "model_name": "Promax HE Store", "model_qualifier": "90 Litre", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 52.3, "output_kw_max": 24.0, "final_year_of_manufacture": 2015, "raw": ["015062", "000005", "0", "2024/Jan/31 10:17", "Baxi Heating", "Potterton", "Promax HE Store", "90 Litre", "GC No. 41-601-24", "2006", "2015", "1", "1", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "87.9", "80.8", "", "52.3", "", "2", "", "", "106", "1", "2", "166", "", "2", "2", "0", "90", "0", "45", "2", "60", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.2", "96.9", "", "", "", "", "95.0"]} -{"pcdb_id": 15063, "brand_name": "Potterton", "model_name": "Promax HE Store", "model_qualifier": "115 Litre", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 50.4, "output_kw_max": 24.0, "final_year_of_manufacture": 2015, "raw": ["015063", "000005", "0", "2024/Jan/31 10:17", "Baxi Heating", "Potterton", "Promax HE Store", "115 Litre", "GC No. 41-591-76", "2006", "2015", "1", "1", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "87.9", "80.8", "", "50.4", "", "2", "", "", "106", "1", "2", "166", "", "2", "2", "0", "115", "0", "45", "2", "60", "", "0", "", "", "", "", "", "", "", "", "", "0", "0", "", "0005", "", "", "", "", "", "", "", "", "87.2", "96.9", "", "", "", "", "95.0"]} -{"pcdb_id": 15064, "brand_name": "Potterton", "model_name": "Promax HE Store", "model_qualifier": "150 Litre", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 80.9, "comparative_hot_water_efficiency_pct": 47.0, "output_kw_max": 24.0, "final_year_of_manufacture": 2015, "raw": ["015064", "000005", "0", "2024/Jan/31 10:17", "Baxi Heating", "Potterton", "Promax HE Store", "150 Litre", "GC No 41-591-77", "2006", "2015", "1", "1", "1", "2", "0", "", "", "2", "2", "2", "24.0", "24.0", "", "", "87.9", "80.9", "", "47.0", "", "2", "", "", "106", "1", "2", "166", "", "2", "2", "0", "150", "0", "45", "2", "60", "", "0", "", "", "", "", "", "", "", "", "", "0", "0", "", "0005", "", "", "", "", "", "", "", "", "87.2", "96.9", "", "", "", "", "95.0"]} -{"pcdb_id": 15067, "brand_name": "Vokera", "model_name": "Compact", "model_qualifier": "35 HE", "winter_efficiency_pct": 85.2, "summer_efficiency_pct": 76.6, "comparative_hot_water_efficiency_pct": 53.9, "output_kw_max": 33.8, "final_year_of_manufacture": 2013, "raw": ["015067", "000011", "0", "2014/May/09 12:49", "Vokera", "Vokera", "Compact", "35 HE", "", "2005", "2013", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "33.8", "33.8", "", "", "85.2", "76.6", "", "53.9", "", "2", "", "", "104", "1", "2", "153", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.6", "89.9", "", "", "", "", "89.5"]} -{"pcdb_id": 15068, "brand_name": "Vokera", "model_name": "Unica", "model_qualifier": "28 HE", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 86.8, "comparative_hot_water_efficiency_pct": 69.6, "output_kw_max": 19.6, "final_year_of_manufacture": null, "raw": ["015068", "000011", "0", "2012/Nov/06 13:20", "Vokera", "Vokera", "Unica", "28 HE", "4709483", "2006", "current", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "19.6", "19.6", "", "", "88.2", "86.8", "", "69.6", "", "2", "", "", "104", "1", "2", "150", "", "0", "", "", "0", "0", "", "", "", "", "1", "7.57", "159.0", "0.0015", "1.44242", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.5", "97.0", "", "", "", "", "95.4"]} -{"pcdb_id": 15069, "brand_name": "Vokera", "model_name": "Unica", "model_qualifier": "32 HE", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 55.9, "output_kw_max": 24.45, "final_year_of_manufacture": null, "raw": ["015069", "000011", "0", "2011/Mar/24 12:37", "Vokera", "Vokera", "Unica", "32 HE", "4709485", "2006", "current", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "24.45", "24.45", "", "", "88.2", "79.6", "", "55.9", "", "2", "", "", "104", "1", "2", "150", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.1", "97.1", "", "", "", "", "95.4"]} -{"pcdb_id": 15070, "brand_name": "Vokera", "model_name": "Unica", "model_qualifier": "HE", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 55.9, "output_kw_max": 29.31, "final_year_of_manufacture": null, "raw": ["015070", "000011", "0", "2007/May/24 10:25", "Vokera", "Vokera", "Unica", "HE", "", "2006", "current", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "29.31", "29.31", "", "", "88.1", "79.5", "", "55.9", "", "2", "", "", "104", "1", "2", "150", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "97.1", "", "", "", "", "95.4"]} -{"pcdb_id": 15072, "brand_name": "Vokera", "model_name": "Mynute", "model_qualifier": "12 HE", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 11.84, "final_year_of_manufacture": null, "raw": ["015072", "000011", "0", "2012/Mar/27 10:12", "Vokera", "Vokera", "Mynute", "12 HE", "4109454", "2006", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "11.84", "11.84", "", "", "88.1", "79.1", "", "57.8", "", "2", "", "", "102", "1", "2", "150", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.9", "96.6", "", "", "", "", "95.1"]} -{"pcdb_id": 15073, "brand_name": "Vokera", "model_name": "Mynute", "model_qualifier": "15 HE", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 14.81, "final_year_of_manufacture": null, "raw": ["015073", "000011", "0", "2012/Mar/30 09:39", "Vokera", "Vokera", "Mynute", "15 HE", "4109456", "2006", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "14.81", "14.81", "", "", "88.1", "79.1", "", "57.8", "", "2", "", "", "102", "1", "2", "150", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.9", "96.6", "", "", "", "", "95.1"]} -{"pcdb_id": 15074, "brand_name": "Vokera", "model_name": "Mynute", "model_qualifier": "20 HE", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 19.68, "final_year_of_manufacture": null, "raw": ["015074", "000011", "0", "2012/Mar/27 10:12", "Vokera", "Vokera", "Mynute", "20 HE", "4109458", "2006", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "19.68", "19.68", "", "", "88.1", "79.1", "", "57.8", "", "2", "", "", "102", "1", "2", "150", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.7", "96.9", "", "", "", "", "95.3"]} -{"pcdb_id": 15075, "brand_name": "Vokera", "model_name": "Mynute", "model_qualifier": "25 HE", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 24.53, "final_year_of_manufacture": null, "raw": ["015075", "000011", "0", "2012/Mar/27 10:12", "Vokera", "Vokera", "Mynute", "25 HE", "4109460", "2006", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "24.53", "24.53", "", "", "88.1", "79.1", "", "57.8", "", "2", "", "", "102", "1", "2", "150", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.4", "96.9", "", "", "", "", "95.3"]} -{"pcdb_id": 15076, "brand_name": "Vokera", "model_name": "Mynute", "model_qualifier": "30 HE", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 29.31, "final_year_of_manufacture": null, "raw": ["015076", "000011", "0", "2012/Mar/27 10:12", "Vokera", "Vokera", "Mynute", "30 HE", "4109462", "2006", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "29.31", "29.31", "", "", "88.1", "79.1", "", "57.8", "", "2", "", "", "102", "1", "2", "150", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "97.1", "", "", "", "", "95.4"]} -{"pcdb_id": 15077, "brand_name": "Vokera", "model_name": "Mynute", "model_qualifier": "HE", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 33.67, "final_year_of_manufacture": null, "raw": ["015077", "000011", "0", "2012/Mar/27 10:12", "Vokera", "Vokera", "Mynute", "HE", "", "2006", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "33.67", "33.67", "", "", "88.1", "79.1", "", "57.8", "", "2", "", "", "102", "1", "2", "165", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.7", "97.1", "", "", "", "", "95.3"]} -{"pcdb_id": 15078, "brand_name": "Remeha", "model_name": "Avanta", "model_qualifier": "18V", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 17.6, "final_year_of_manufacture": null, "raw": ["015078", "000005", "0", "2012/Apr/11 14:49", "Broag Remeha", "Remeha", "Avanta", "18V", "", "2006", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "17.6", "17.6", "", "", "88.5", "79.5", "", "58.1", "", "2", "", "", "102", "1", "2", "50", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.6", "97.9", "", "", "", "", "96.2"]} -{"pcdb_id": 15080, "brand_name": "Trianco", "model_name": "Contractor Combi 110 External", "model_qualifier": "", "winter_efficiency_pct": 84.7, "summer_efficiency_pct": 76.6, "comparative_hot_water_efficiency_pct": 47.2, "output_kw_max": 31.6, "final_year_of_manufacture": null, "raw": ["015080", "000062", "0", "2024/Jan/31 10:17", "Trianco Heating Products", "Trianco", "Contractor Combi 110 External", "", "", "2006", "current", "4", "1", "2", "2", "0", "", "", "1", "3", "2", "31.6", "31.6", "", "", "84.7", "76.6", "", "47.2", "", "2", "", "", "203", "1", "1", "148", "0", "2", "1", "0", "31", "0", "25", "1", "80", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.6", "87.0", "", "", "", "", "87.2"]} -{"pcdb_id": 15081, "brand_name": "Trianco", "model_name": "Iona Combi 110 External", "model_qualifier": "", "winter_efficiency_pct": 84.7, "summer_efficiency_pct": 76.6, "comparative_hot_water_efficiency_pct": 47.2, "output_kw_max": 31.6, "final_year_of_manufacture": null, "raw": ["015081", "000062", "0", "2024/Jan/31 10:17", "Trianco Heating Products", "Trianco", "Iona Combi 110 External", "", "", "2006", "current", "4", "1", "2", "2", "0", "", "", "1", "3", "2", "31.6", "31.6", "", "", "84.7", "76.6", "", "47.2", "", "2", "", "", "203", "1", "1", "148", "0", "2", "1", "0", "31", "0", "25", "1", "80", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.6", "87.0", "", "", "", "", "87.2"]} -{"pcdb_id": 15082, "brand_name": "Trianco", "model_name": "Iona Combi 110", "model_qualifier": "", "winter_efficiency_pct": 84.7, "summer_efficiency_pct": 76.6, "comparative_hot_water_efficiency_pct": 47.2, "output_kw_max": 31.6, "final_year_of_manufacture": null, "raw": ["015082", "000062", "0", "2024/Jan/31 10:17", "Trianco Heating Products", "Trianco", "Iona Combi 110", "", "", "2006", "current", "4", "1", "1", "2", "0", "", "", "1", "3", "2", "31.6", "31.6", "", "", "84.7", "76.6", "", "47.2", "", "2", "", "", "203", "1", "1", "148", "0", "2", "1", "0", "31", "0", "25", "1", "80", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.6", "87.0", "", "", "", "", "87.2"]} -{"pcdb_id": 15083, "brand_name": "Trianco", "model_name": "Contractor Combi 110", "model_qualifier": "", "winter_efficiency_pct": 84.7, "summer_efficiency_pct": 76.6, "comparative_hot_water_efficiency_pct": 47.2, "output_kw_max": 31.6, "final_year_of_manufacture": null, "raw": ["015083", "000062", "0", "2024/Jan/31 10:17", "Trianco Heating Products", "Trianco", "Contractor Combi 110", "", "2307", "2006", "current", "4", "1", "1", "2", "0", "", "", "1", "3", "2", "31.6", "31.6", "", "", "84.7", "76.6", "", "47.2", "", "2", "", "", "203", "1", "1", "148", "0", "2", "1", "0", "31", "0", "25", "1", "80", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.6", "87.0", "", "", "", "", "87.2"]} -{"pcdb_id": 15084, "brand_name": "Gledhill", "model_name": "GB35C", "model_qualifier": "AGB5035", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 56.3, "output_kw_max": 28.9, "final_year_of_manufacture": null, "raw": ["015084", "000072", "0", "2006/Sep/28 13:36", "Gledhill Water Storage", "Gledhill", "GB35C", "AGB5035", "GC No 47-317-01", "2006", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28.9", "28.9", "", "", "88.7", "80.1", "", "56.3", "", "2", "", "", "104", "1", "2", "155", "15", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.5", "97.8", "", "", "", "", "96.3"]} -{"pcdb_id": 15085, "brand_name": "Ideal", "model_name": "Mini", "model_qualifier": "HE C32", "winter_efficiency_pct": 85.5, "summer_efficiency_pct": 76.9, "comparative_hot_water_efficiency_pct": 54.1, "output_kw_max": 32.2, "final_year_of_manufacture": 2011, "raw": ["015085", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "Mini", "HE C32", "47-348-41", "2006", "2011", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "32.2", "32.2", "", "", "85.5", "76.9", "", "54.1", "", "2", "", "", "104", "1", "2", "150", "7", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.1", "90.7", "", "", "", "", "90.0"]} -{"pcdb_id": 15087, "brand_name": "Baxi", "model_name": "Solo", "model_qualifier": "18 HE", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 17.81, "final_year_of_manufacture": 2010, "raw": ["015087", "000005", "0", "2020/Dec/07 12:12", "Baxi Heating UK", "Baxi", "Solo", "18 HE", "GC No. 41-075-51", "2006", "2010", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "17.81", "17.81", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "96.8", "", "", "", "", "95.2"]} -{"pcdb_id": 15088, "brand_name": "Baxi", "model_name": "Solo", "model_qualifier": "12 HE", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 11.82, "final_year_of_manufacture": 2010, "raw": ["015088", "000005", "0", "2020/Dec/07 12:13", "Baxi Heating UK", "Baxi", "Solo", "12 HE", "Gc No. 41-075-50", "2006", "2010", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "11.82", "11.82", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "80", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.6", "96.5", "", "", "", "", "95.0"]} -{"pcdb_id": 15090, "brand_name": "Worcester", "model_name": "Greenstar Heatslave", "model_qualifier": "25/32", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 81.9, "comparative_hot_water_efficiency_pct": 41.6, "output_kw_max": 32.0, "final_year_of_manufacture": 2013, "raw": ["015090", "000035", "0", "2024/Jan/31 10:17", "Worcester Bosch Group", "Worcester", "Greenstar Heatslave", "25/32", "", "2006", "2013", "4", "1", "1", "2", "0", "", "", "2", "3", "2", "25", "32", "", "", "88.0", "81.9", "", "41.6", "", "2", "", "", "203", "1", "1", "123", "0", "1", "1", "0", "69", "0", "25", "3", "82", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.8", "94.4", "", "", "", "", "93.9"]} -{"pcdb_id": 15091, "brand_name": "Worcester", "model_name": "Greenstar Heatslave", "model_qualifier": "12/18", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 82.1, "comparative_hot_water_efficiency_pct": 41.6, "output_kw_max": 18.0, "final_year_of_manufacture": 2013, "raw": ["015091", "000035", "0", "2024/Jan/31 10:17", "Worcester Bosch Group", "Worcester", "Greenstar Heatslave", "12/18", "", "2006", "2013", "4", "1", "1", "2", "0", "", "", "2", "3", "2", "12", "18", "", "", "88.2", "82.1", "", "41.6", "", "2", "", "", "203", "1", "1", "135", "0", "1", "1", "0", "69", "0", "25", "3", "82", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.6", "95.3", "", "", "", "", "94.4"]} -{"pcdb_id": 15093, "brand_name": "Grant", "model_name": "Vortex Utility 15-21", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 80.6, "comparative_hot_water_efficiency_pct": 58.9, "output_kw_max": 21.0, "final_year_of_manufacture": null, "raw": ["015093", "000048", "0", "2012/Mar/27 10:12", "Grant Engineering (UK)", "Grant", "Vortex Utility 15-21", "", "", "2006", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "15", "21", "", "", "88.4", "80.6", "", "58.9", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "88.9", "97.1", "", "", "", "", "95.5"]} -{"pcdb_id": 15094, "brand_name": "Grant", "model_name": "Vortex Outdoor Module 15-21", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 80.6, "comparative_hot_water_efficiency_pct": 58.9, "output_kw_max": 21.0, "final_year_of_manufacture": null, "raw": ["015094", "000048", "0", "2012/Mar/27 10:12", "Grant Engineering (UK)", "Grant", "Vortex Outdoor Module 15-21", "", "", "2006", "current", "4", "1", "2", "1", "0", "", "", "2", "3", "2", "15", "21", "", "", "88.4", "80.6", "", "58.9", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "88.9", "97.1", "", "", "", "", "95.5"]} -{"pcdb_id": 15095, "brand_name": "Grant", "model_name": "Vortex Outdoor", "model_qualifier": "Combi 21", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 82.3, "comparative_hot_water_efficiency_pct": 45.0, "output_kw_max": 21.0, "final_year_of_manufacture": null, "raw": ["015095", "000048", "0", "2024/Jan/31 10:17", "Grant Engineering (UK)", "Grant", "Vortex Outdoor", "Combi 21", "", "2006", "current", "4", "1", "2", "2", "0", "", "", "2", "3", "2", "21", "21", "", "", "88.4", "82.3", "", "45.0", "", "2", "", "", "203", "1", "1", "", "", "1", "", "", "40", "0", "25", "3", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "88.9", "97.1", "", "", "", "", "95.5"]} -{"pcdb_id": 15096, "brand_name": "Grant", "model_name": "Vortex Condensing", "model_qualifier": "Combi 21", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 82.3, "comparative_hot_water_efficiency_pct": 45.0, "output_kw_max": 21.0, "final_year_of_manufacture": null, "raw": ["015096", "000048", "0", "2024/Jan/31 10:17", "Grant Engineering (UK)", "Grant", "Vortex Condensing", "Combi 21", "", "2006", "current", "4", "1", "1", "2", "0", "", "", "2", "3", "2", "21", "21", "", "", "88.4", "82.3", "", "45.0", "", "2", "", "", "203", "1", "1", "", "", "1", "", "", "40", "0", "25", "3", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "88.9", "97.1", "", "", "", "", "95.5"]} -{"pcdb_id": 15097, "brand_name": "Ideal", "model_name": "mini", "model_qualifier": "HE C32", "winter_efficiency_pct": 87.4, "summer_efficiency_pct": 78.8, "comparative_hot_water_efficiency_pct": 55.4, "output_kw_max": 32.2, "final_year_of_manufacture": 2011, "raw": ["015097", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "mini", "HE C32", "47-348-41", "2006", "2011", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "32.2", "32.2", "", "", "87.4", "78.8", "", "55.4", "", "2", "0", "", "104", "1", "2", "150", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.1", "92.7", "", "", "", "", "92.0"]} -{"pcdb_id": 15098, "brand_name": "Potterton", "model_name": "Promax", "model_qualifier": "12 HE Plus", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 11.82, "final_year_of_manufacture": 2006, "raw": ["015098", "000005", "0", "2012/Mar/27 10:12", "Baxi Heating UK", "Potterton", "Promax", "12 HE Plus", "GC No 41-591-79", "2006", "2006", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "11.82", "11.82", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "80", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.6", "96.5", "", "", "", "", "95.0"]} -{"pcdb_id": 15099, "brand_name": "Potterton", "model_name": "Promax", "model_qualifier": "18 HE Plus", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 17.81, "final_year_of_manufacture": 2006, "raw": ["015099", "000005", "0", "2012/Mar/27 10:12", "Baxi Heating UK", "Potterton", "Promax", "18 HE Plus", "GC No. 41-591-80", "2006", "2006", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "17.81", "17.81", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "96.8", "", "", "", "", "95.2"]} -{"pcdb_id": 15100, "brand_name": "Vaillant", "model_name": "Ecotec plus 415", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 15.0, "final_year_of_manufacture": 2015, "raw": ["015100", "000031", "0", "2012/Mar/27 10:12", "Vaillant", "Vaillant", "Ecotec plus 415", "", "GC No. 41.044.53", "2006", "2015", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "15", "15", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "60", "8", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0045", "", "", "", "", "", "", "", "", "88.6", "96.5", "", "", "", "", "95.0"]} -{"pcdb_id": 15101, "brand_name": "Vaillant", "model_name": "Ecotec plus 418", "model_qualifier": "", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 18.6, "final_year_of_manufacture": 2015, "raw": ["015101", "000031", "0", "2012/Mar/27 10:12", "Vaillant", "Vaillant", "Ecotec plus 418", "", "GC No. 41.044.54", "2006", "2015", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18.6", "18.6", "", "", "88.2", "79.2", "", "57.8", "", "2", "", "", "102", "1", "2", "60", "8", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0045", "", "", "", "", "", "", "", "", "88.6", "96.9", "", "", "", "", "95.4"]} -{"pcdb_id": 15102, "brand_name": "Vaillant", "model_name": "Ecotec plus 418", "model_qualifier": "", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 18.6, "final_year_of_manufacture": 2019, "raw": ["015102", "000031", "0", "2019/Mar/04 10:05", "Vaillant", "Vaillant", "Ecotec plus 418", "", "", "2006", "2019", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "18.6", "18.6", "", "", "89.2", "80.2", "", "58.6", "", "2", "1", "", "102", "1", "2", "60", "8", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.5", "99.1", "", "", "", "", "97.5"]} -{"pcdb_id": 15103, "brand_name": "Vaillant", "model_name": "Ecotec plus 415", "model_qualifier": "", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 15.0, "final_year_of_manufacture": 2019, "raw": ["015103", "000031", "0", "2019/Mar/04 10:05", "Vaillant", "Vaillant", "Ecotec plus 415", "", "", "2006", "2019", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "15", "15", "", "", "89.0", "80.0", "", "58.4", "", "2", "1", "", "102", "1", "2", "60", "8", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.5", "98.6", "", "", "", "", "97.1"]} -{"pcdb_id": 15104, "brand_name": "Vaillant", "model_name": "Ecotec plus 438", "model_qualifier": "", "winter_efficiency_pct": 89.5, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 58.8, "output_kw_max": 38.0, "final_year_of_manufacture": 2019, "raw": ["015104", "000031", "0", "2019/Mar/04 10:08", "Vaillant", "Vaillant", "Ecotec plus 438", "", "", "2006", "2019", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "38", "38", "", "", "89.5", "80.5", "", "58.8", "", "2", "1", "", "102", "1", "2", "60", "8", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "91.3", "99.7", "", "", "", "", "98.1"]} -{"pcdb_id": 15105, "brand_name": "Vaillant", "model_name": "Ecotec plus 428", "model_qualifier": "", "winter_efficiency_pct": 90.0, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 59.2, "output_kw_max": 28.2, "final_year_of_manufacture": 2019, "raw": ["015105", "000031", "0", "2019/Mar/04 10:07", "Vaillant", "Vaillant", "Ecotec plus 428", "", "", "2006", "2019", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "28.2", "28.2", "", "", "90.0", "81.0", "", "59.2", "", "2", "0", "", "102", "1", "2", "60", "8", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.8", "99.0", "", "", "", "", "97.3"]} -{"pcdb_id": 15106, "brand_name": "Vaillant", "model_name": "Ecotec plus 428", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 28.2, "final_year_of_manufacture": 2015, "raw": ["015106", "000031", "0", "2012/Mar/27 10:12", "Vaillant", "Vaillant", "Ecotec plus 428", "", "GC No. 41.044.55", "2006", "2015", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "28.2", "28.2", "", "", "88.1", "79.1", "", "57.8", "", "2", "", "", "102", "1", "2", "60", "8", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0045", "", "", "", "", "", "", "", "", "88.7", "96.9", "", "", "", "", "95.3"]} -{"pcdb_id": 15107, "brand_name": "Vaillant", "model_name": "Ecotec plus 438", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 38.0, "final_year_of_manufacture": 2015, "raw": ["015107", "000031", "0", "2015/Sep/21 14:23", "Vaillant", "Vaillant", "Ecotec plus 438", "", "GC No. 41.044.57", "2006", "2015", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "38", "38", "", "", "88.5", "79.5", "", "58.1", "", "2", "", "", "102", "1", "2", "60", "8", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0045", "", "", "", "", "", "", "", "", "89.3", "97.5", "", "", "", "", "95.9"]} -{"pcdb_id": 15109, "brand_name": "Mistral", "model_name": "KUT 2 70/90", "model_qualifier": "", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 26.4, "final_year_of_manufacture": null, "raw": ["015109", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "KUT 2 70/90", "", "", "2006", "current", "4", "1", "1", "1", "0", "", "", "1", "3", "2", "20.5", "26.4", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.3", "87.3", "", "", "", "", "87.1"]} -{"pcdb_id": 15110, "brand_name": "Mistral", "model_name": "KUT 50/90 Contract", "model_qualifier": "", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 26.4, "final_year_of_manufacture": null, "raw": ["015110", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "KUT 50/90 Contract", "", "", "2006", "current", "4", "1", "1", "1", "0", "", "", "1", "3", "2", "14.6", "26.4", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.3", "87.3", "", "", "", "", "87.1"]} -{"pcdb_id": 15111, "brand_name": "Mistral", "model_name": "KUT 1 50/70", "model_qualifier": "", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 20.5, "final_year_of_manufacture": null, "raw": ["015111", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "KUT 1 50/70", "", "", "2006", "current", "4", "1", "1", "1", "0", "", "", "1", "3", "2", "14.6", "20.5", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.3", "87.3", "", "", "", "", "87.1"]} -{"pcdb_id": 15112, "brand_name": "Mistral", "model_name": "SS 50/90 Contract", "model_qualifier": "", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 26.4, "final_year_of_manufacture": null, "raw": ["015112", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "SS 50/90 Contract", "", "", "2006", "current", "4", "1", "1", "1", "0", "", "", "1", "3", "2", "14.6", "26.4", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.3", "87.3", "", "", "", "", "87.1"]} -{"pcdb_id": 15113, "brand_name": "Mistral", "model_name": "S2 70/90", "model_qualifier": "", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 26.4, "final_year_of_manufacture": null, "raw": ["015113", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "S2 70/90", "", "", "2006", "current", "4", "1", "1", "1", "0", "", "", "1", "3", "2", "20.5", "26.4", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.3", "87.3", "", "", "", "", "87.1"]} -{"pcdb_id": 15114, "brand_name": "Mistral", "model_name": "S1 50/70", "model_qualifier": "", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 20.5, "final_year_of_manufacture": null, "raw": ["015114", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "S1 50/70", "", "", "2006", "current", "4", "1", "1", "1", "0", "", "", "1", "3", "2", "14.6", "20.5", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.3", "87.3", "", "", "", "", "87.1"]} -{"pcdb_id": 15115, "brand_name": "Mistral", "model_name": "C 50/90 Standard Contract", "model_qualifier": "", "winter_efficiency_pct": 84.8, "summer_efficiency_pct": 76.7, "comparative_hot_water_efficiency_pct": 46.9, "output_kw_max": 26.4, "final_year_of_manufacture": null, "raw": ["015115", "000056", "0", "2024/Jan/31 10:17", "Mistral Boilers", "Mistral", "C 50/90 Standard Contract", "", "", "2006", "current", "4", "1", "1", "2", "0", "", "", "1", "3", "2", "14.6", "26.4", "", "", "84.8", "76.7", "", "46.9", "", "2", "", "", "203", "1", "1", "", "", "2", "", "0", "40", "0", "25", "1", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.3", "87.1", "", "", "", "", "87.0"]} -{"pcdb_id": 15116, "brand_name": "Mistral", "model_name": "C1 50/70 Standard", "model_qualifier": "", "winter_efficiency_pct": 84.8, "summer_efficiency_pct": 76.7, "comparative_hot_water_efficiency_pct": 46.9, "output_kw_max": 20.5, "final_year_of_manufacture": null, "raw": ["015116", "000056", "0", "2024/Jan/31 10:17", "Mistral Boilers", "Mistral", "C1 50/70 Standard", "", "", "2006", "current", "4", "1", "1", "2", "0", "", "", "1", "3", "2", "14.6", "20.5", "", "", "84.8", "76.7", "", "46.9", "", "2", "", "", "203", "1", "1", "", "", "2", "", "0", "40", "0", "25", "1", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.3", "87.3", "", "", "", "", "87.1"]} -{"pcdb_id": 15117, "brand_name": "Mistral", "model_name": "C2 70/90 Standard", "model_qualifier": "", "winter_efficiency_pct": 84.8, "summer_efficiency_pct": 76.7, "comparative_hot_water_efficiency_pct": 46.9, "output_kw_max": 26.4, "final_year_of_manufacture": null, "raw": ["015117", "000056", "0", "2024/Jan/31 10:17", "Mistral Boilers", "Mistral", "C2 70/90 Standard", "", "", "2006", "current", "4", "1", "1", "2", "0", "", "", "1", "3", "2", "20.5", "26.4", "", "", "84.8", "76.7", "", "46.9", "", "2", "", "", "203", "1", "1", "", "", "2", "", "0", "40", "0", "25", "1", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.3", "87.3", "", "", "", "", "87.1"]} -{"pcdb_id": 15118, "brand_name": "Mistral", "model_name": "BH 50/90 Contract", "model_qualifier": "", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 26.4, "final_year_of_manufacture": null, "raw": ["015118", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "BH 50/90 Contract", "", "", "2006", "current", "4", "1", "1", "1", "0", "", "", "1", "3", "2", "14.6", "26.4", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.3", "87.3", "", "", "", "", "87.1"]} -{"pcdb_id": 15119, "brand_name": "Mistral", "model_name": "BH 2 70/90", "model_qualifier": "", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 26.4, "final_year_of_manufacture": null, "raw": ["015119", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "BH 2 70/90", "", "", "2006", "current", "4", "1", "1", "1", "0", "", "", "1", "3", "2", "20.5", "26.4", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.3", "87.3", "", "", "", "", "87.1"]} -{"pcdb_id": 15120, "brand_name": "Mistral", "model_name": "BH 1 50/70", "model_qualifier": "", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 20.5, "final_year_of_manufacture": null, "raw": ["015120", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "BH 1 50/70", "", "", "2006", "current", "4", "1", "1", "1", "0", "", "", "1", "3", "2", "14.6", "20.5", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.3", "87.3", "", "", "", "", "87.1"]} -{"pcdb_id": 15121, "brand_name": "Mistral", "model_name": "C2 70/90 Plus", "model_qualifier": "", "winter_efficiency_pct": 84.8, "summer_efficiency_pct": 76.7, "comparative_hot_water_efficiency_pct": 46.9, "output_kw_max": 26.4, "final_year_of_manufacture": null, "raw": ["015121", "000056", "0", "2024/Jan/31 10:17", "Mistral Boilers", "Mistral", "C2 70/90 Plus", "", "", "2006", "current", "4", "1", "1", "2", "0", "", "", "1", "3", "2", "20.5", "26.4", "", "", "84.8", "76.7", "", "46.9", "", "2", "", "", "203", "1", "1", "230", "0", "2", "", "0", "40", "0", "25", "1", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.3", "87.3", "", "", "", "", "87.1"]} -{"pcdb_id": 15122, "brand_name": "Mistral", "model_name": "C1 50/70 Plus", "model_qualifier": "", "winter_efficiency_pct": 84.8, "summer_efficiency_pct": 76.7, "comparative_hot_water_efficiency_pct": 46.9, "output_kw_max": 20.5, "final_year_of_manufacture": null, "raw": ["015122", "000056", "0", "2024/Jan/31 10:17", "Mistral Boilers", "Mistral", "C1 50/70 Plus", "", "", "2006", "current", "4", "1", "1", "2", "0", "", "", "1", "3", "2", "14.6", "20.5", "", "", "84.8", "76.7", "", "46.9", "", "2", "", "", "203", "1", "1", "230", "0", "2", "", "0", "40", "0", "25", "1", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.3", "87.3", "", "", "", "", "87.1"]} -{"pcdb_id": 15123, "brand_name": "Mistral", "model_name": "C 50/90 Plus", "model_qualifier": "", "winter_efficiency_pct": 84.8, "summer_efficiency_pct": 76.7, "comparative_hot_water_efficiency_pct": 46.9, "output_kw_max": 26.4, "final_year_of_manufacture": null, "raw": ["015123", "000056", "0", "2024/Jan/31 10:17", "Mistral Boilers", "Mistral", "C 50/90 Plus", "", "", "2006", "current", "4", "1", "1", "2", "0", "", "", "1", "3", "2", "14.6", "26.4", "", "", "84.8", "76.7", "", "46.9", "", "2", "", "", "203", "1", "1", "230", "0", "2", "", "0", "40", "0", "25", "1", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.3", "87.3", "", "", "", "", "87.1"]} -{"pcdb_id": 15124, "brand_name": "Mistral", "model_name": "OD 1 50/70", "model_qualifier": "", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 20.5, "final_year_of_manufacture": null, "raw": ["015124", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "OD 1 50/70", "", "", "2006", "current", "4", "1", "2", "1", "0", "", "", "1", "3", "2", "14.6", "20.5", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.3", "87.3", "", "", "", "", "87.1"]} -{"pcdb_id": 15125, "brand_name": "Mistral", "model_name": "OD 50/90", "model_qualifier": "", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 26.4, "final_year_of_manufacture": null, "raw": ["015125", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "OD 50/90", "", "", "2006", "current", "4", "1", "2", "1", "0", "", "", "1", "3", "2", "14.6", "26.4", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.3", "87.3", "", "", "", "", "87.1"]} -{"pcdb_id": 15126, "brand_name": "Mistral", "model_name": "OD 2 70/90", "model_qualifier": "", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 26.4, "final_year_of_manufacture": null, "raw": ["015126", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "OD 2 70/90", "", "", "2006", "current", "4", "1", "2", "1", "0", "", "", "1", "3", "2", "20.5", "26.4", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "230", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.3", "87.3", "", "", "", "", "87.1"]} -{"pcdb_id": 15127, "brand_name": "Mistral", "model_name": "OD1 SS 50/70", "model_qualifier": "", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 20.5, "final_year_of_manufacture": null, "raw": ["015127", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "OD1 SS 50/70", "", "", "2006", "current", "4", "1", "2", "1", "0", "", "", "1", "3", "2", "14.6", "20.5", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.3", "87.3", "", "", "", "", "87.1"]} -{"pcdb_id": 15128, "brand_name": "Mistral", "model_name": "OD2 SS 70/90", "model_qualifier": "", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 26.4, "final_year_of_manufacture": null, "raw": ["015128", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "OD2 SS 70/90", "", "", "2006", "current", "4", "1", "2", "1", "0", "", "", "1", "3", "2", "20.5", "26.4", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.3", "87.3", "", "", "", "", "87.1"]} -{"pcdb_id": 15129, "brand_name": "Mistral", "model_name": "OD SS 50/90 Contract", "model_qualifier": "", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 26.4, "final_year_of_manufacture": null, "raw": ["015129", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "OD SS 50/90 Contract", "", "", "2006", "current", "4", "1", "2", "1", "0", "", "", "1", "3", "2", "14.6", "26.4", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.3", "87.3", "", "", "", "", "87.1"]} -{"pcdb_id": 15130, "brand_name": "Mistral", "model_name": "ODC1 50/70 Standard", "model_qualifier": "", "winter_efficiency_pct": 84.8, "summer_efficiency_pct": 76.7, "comparative_hot_water_efficiency_pct": 46.9, "output_kw_max": 20.5, "final_year_of_manufacture": null, "raw": ["015130", "000056", "0", "2024/Jan/31 10:17", "Mistral Boilers", "Mistral", "ODC1 50/70 Standard", "", "", "2006", "current", "4", "1", "2", "2", "0", "", "", "1", "3", "2", "14.6", "20.5", "", "", "84.8", "76.7", "", "46.9", "", "2", "", "", "203", "1", "1", "230", "0", "2", "", "0", "40", "0", "25", "1", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.3", "87.3", "", "", "", "", "87.1"]} -{"pcdb_id": 15131, "brand_name": "Mistral", "model_name": "ODC 50/90 Standard Contract", "model_qualifier": "", "winter_efficiency_pct": 84.8, "summer_efficiency_pct": 76.7, "comparative_hot_water_efficiency_pct": 46.9, "output_kw_max": 26.4, "final_year_of_manufacture": null, "raw": ["015131", "000056", "0", "2024/Jan/31 10:17", "Mistral Boilers", "Mistral", "ODC 50/90 Standard Contract", "", "", "2006", "current", "4", "1", "2", "2", "0", "", "", "1", "3", "2", "14.6", "26.4", "", "", "84.8", "76.7", "", "46.9", "", "2", "", "", "203", "1", "1", "230", "0", "2", "", "0", "40", "0", "25", "1", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.3", "87.3", "", "", "", "", "87.1"]} -{"pcdb_id": 15132, "brand_name": "Mistral", "model_name": "ODC2 70/90 Standard", "model_qualifier": "", "winter_efficiency_pct": 84.8, "summer_efficiency_pct": 76.7, "comparative_hot_water_efficiency_pct": 46.9, "output_kw_max": 26.4, "final_year_of_manufacture": null, "raw": ["015132", "000056", "0", "2024/Jan/31 10:17", "Mistral Boilers", "Mistral", "ODC2 70/90 Standard", "", "", "2006", "current", "4", "1", "2", "2", "0", "", "", "1", "3", "2", "20.5", "26.4", "", "", "84.8", "76.7", "", "46.9", "", "2", "", "", "203", "1", "1", "", "", "2", "", "0", "40", "0", "25", "1", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.3", "87.3", "", "", "", "", "87.1"]} -{"pcdb_id": 15133, "brand_name": "Mistral", "model_name": "ODC 50/90 Plus Contract", "model_qualifier": "", "winter_efficiency_pct": 84.8, "summer_efficiency_pct": 76.7, "comparative_hot_water_efficiency_pct": 46.9, "output_kw_max": 26.4, "final_year_of_manufacture": null, "raw": ["015133", "000056", "0", "2024/Jan/31 10:17", "Mistral Boilers", "Mistral", "ODC 50/90 Plus Contract", "", "", "2006", "current", "4", "1", "2", "2", "0", "", "", "1", "3", "2", "14.6", "26.4", "", "", "84.8", "76.7", "", "46.9", "", "2", "", "", "203", "1", "1", "230", "0", "2", "", "0", "40", "0", "25", "1", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.3", "87.3", "", "", "", "", "87.1"]} -{"pcdb_id": 15134, "brand_name": "Mistral", "model_name": "ODC2 70/90 Plus", "model_qualifier": "", "winter_efficiency_pct": 84.8, "summer_efficiency_pct": 76.7, "comparative_hot_water_efficiency_pct": 46.9, "output_kw_max": 26.4, "final_year_of_manufacture": null, "raw": ["015134", "000056", "0", "2024/Jan/31 10:17", "Mistral Boilers", "Mistral", "ODC2 70/90 Plus", "", "", "2006", "current", "4", "1", "2", "2", "0", "", "", "1", "3", "2", "20.5", "26.4", "", "", "84.8", "76.7", "", "46.9", "", "2", "", "", "203", "1", "1", "230", "0", "2", "", "0", "40", "0", "25", "1", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.3", "87.3", "", "", "", "", "87.1"]} -{"pcdb_id": 15135, "brand_name": "Mistral", "model_name": "OD C1 50/70 Plus", "model_qualifier": "", "winter_efficiency_pct": 84.8, "summer_efficiency_pct": 76.7, "comparative_hot_water_efficiency_pct": 46.9, "output_kw_max": 20.5, "final_year_of_manufacture": null, "raw": ["015135", "000056", "0", "2024/Jan/31 10:17", "Mistral Boilers", "Mistral", "OD C1 50/70 Plus", "", "", "2006", "current", "4", "1", "2", "2", "0", "", "", "1", "3", "2", "14.6", "20.5", "", "", "84.8", "76.7", "", "46.9", "", "2", "", "", "203", "1", "1", "230", "0", "2", "", "0", "40", "0", "25", "1", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.3", "87.3", "", "", "", "", "87.1"]} -{"pcdb_id": 15136, "brand_name": "Mistral", "model_name": "ODC 90/150 Plus", "model_qualifier": "", "winter_efficiency_pct": 84.7, "summer_efficiency_pct": 76.6, "comparative_hot_water_efficiency_pct": 46.9, "output_kw_max": 44.0, "final_year_of_manufacture": null, "raw": ["015136", "000056", "0", "2024/Jan/31 10:17", "Mistral Boilers", "Mistral", "ODC 90/150 Plus", "", "", "2006", "current", "4", "1", "2", "2", "0", "", "", "1", "3", "2", "26.4", "44", "", "", "84.7", "76.6", "", "46.9", "", "2", "", "", "203", "1", "1", "230", "0", "2", "", "0", "40", "0", "25", "1", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.1", "88.4", "", "", "", "", "87.9"]} -{"pcdb_id": 15137, "brand_name": "Mistral", "model_name": "ODC 3 90/120 Plus", "model_qualifier": "", "winter_efficiency_pct": 84.7, "summer_efficiency_pct": 76.6, "comparative_hot_water_efficiency_pct": 46.1, "output_kw_max": 35.2, "final_year_of_manufacture": null, "raw": ["015137", "000056", "0", "2024/Jan/31 10:17", "Mistral Boilers", "Mistral", "ODC 3 90/120 Plus", "", "", "2006", "current", "4", "1", "2", "2", "0", "", "", "1", "3", "2", "26.4", "35.2", "", "", "84.7", "76.6", "", "46.1", "", "2", "", "", "203", "1", "1", "230", "0", "2", "", "0", "60", "0", "25", "1", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.1", "88.4", "", "", "", "", "87.9"]} -{"pcdb_id": 15138, "brand_name": "Mistral", "model_name": "ODC4 120/150 Plus", "model_qualifier": "", "winter_efficiency_pct": 84.7, "summer_efficiency_pct": 76.6, "comparative_hot_water_efficiency_pct": 46.1, "output_kw_max": 44.0, "final_year_of_manufacture": null, "raw": ["015138", "000056", "0", "2024/Jan/31 10:17", "Mistral Boilers", "Mistral", "ODC4 120/150 Plus", "", "", "2006", "current", "4", "1", "2", "2", "0", "", "", "1", "3", "2", "35.2", "44", "", "", "84.7", "76.6", "", "46.1", "", "2", "", "", "203", "1", "1", "230", "0", "2", "", "0", "60", "0", "25", "1", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.1", "88.4", "", "", "", "", "87.9"]} -{"pcdb_id": 15139, "brand_name": "Mistral", "model_name": "ODC 90/150 Standard", "model_qualifier": "", "winter_efficiency_pct": 84.7, "summer_efficiency_pct": 76.6, "comparative_hot_water_efficiency_pct": 46.1, "output_kw_max": 44.0, "final_year_of_manufacture": null, "raw": ["015139", "000056", "0", "2024/Jan/31 10:17", "Mistral Boilers", "Mistral", "ODC 90/150 Standard", "", "", "2006", "current", "4", "1", "2", "2", "0", "", "", "1", "3", "2", "26.4", "44", "", "", "84.7", "76.6", "", "46.1", "", "2", "", "", "203", "1", "1", "230", "0", "2", "", "0", "60", "0", "25", "1", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.1", "88.4", "", "", "", "", "87.9"]} -{"pcdb_id": 15140, "brand_name": "Mistral", "model_name": "ODC4 120/150 Standard", "model_qualifier": "", "winter_efficiency_pct": 84.7, "summer_efficiency_pct": 76.6, "comparative_hot_water_efficiency_pct": 46.1, "output_kw_max": 44.0, "final_year_of_manufacture": null, "raw": ["015140", "000056", "0", "2024/Jan/31 10:17", "Mistral Boilers", "Mistral", "ODC4 120/150 Standard", "", "", "2006", "current", "4", "1", "2", "2", "0", "", "", "1", "3", "2", "35.2", "44", "", "", "84.7", "76.6", "", "46.1", "", "2", "", "", "203", "1", "1", "230", "0", "2", "", "0", "60", "0", "25", "1", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.1", "88.4", "", "", "", "", "87.9"]} -{"pcdb_id": 15141, "brand_name": "Mistral", "model_name": "ODC3 90/120 Standard", "model_qualifier": "", "winter_efficiency_pct": 84.7, "summer_efficiency_pct": 76.6, "comparative_hot_water_efficiency_pct": 46.1, "output_kw_max": 35.2, "final_year_of_manufacture": null, "raw": ["015141", "000056", "0", "2024/Jan/31 10:17", "Mistral Boilers", "Mistral", "ODC3 90/120 Standard", "", "", "2006", "current", "4", "1", "2", "2", "0", "", "", "1", "3", "2", "26.4", "35.2", "", "", "84.7", "76.6", "", "46.1", "", "2", "", "", "203", "1", "1", "230", "0", "2", "", "0", "60", "0", "25", "1", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "0", "", "0002", "", "", "", "", "", "", "", "", "86.1", "88.4", "", "", "", "", "87.9"]} -{"pcdb_id": 15142, "brand_name": "Mistral", "model_name": "OD3 90/120", "model_qualifier": "", "winter_efficiency_pct": 86.6, "summer_efficiency_pct": 74.9, "comparative_hot_water_efficiency_pct": 54.7, "output_kw_max": 35.2, "final_year_of_manufacture": null, "raw": ["015142", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "OD3 90/120", "", "", "2006", "current", "4", "1", "2", "1", "0", "", "", "1", "3", "2", "26.4", "35.2", "", "", "86.6", "74.9", "", "54.7", "", "2", "", "", "201", "1", "1", "230", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.1", "88.4", "", "", "", "", "87.9"]} -{"pcdb_id": 15143, "brand_name": "Mistral", "model_name": "OD4 120/150", "model_qualifier": "", "winter_efficiency_pct": 86.6, "summer_efficiency_pct": 74.9, "comparative_hot_water_efficiency_pct": 54.7, "output_kw_max": 44.0, "final_year_of_manufacture": null, "raw": ["015143", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "OD4 120/150", "", "", "2006", "current", "4", "1", "2", "1", "0", "", "", "1", "3", "2", "35.2", "44", "", "", "86.6", "74.9", "", "54.7", "", "2", "", "", "201", "1", "1", "230", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.1", "88.4", "", "", "", "", "87.9"]} -{"pcdb_id": 15144, "brand_name": "Mistral", "model_name": "OD 90/150 Contract", "model_qualifier": "", "winter_efficiency_pct": 86.6, "summer_efficiency_pct": 74.9, "comparative_hot_water_efficiency_pct": 54.7, "output_kw_max": 44.0, "final_year_of_manufacture": null, "raw": ["015144", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "OD 90/150 Contract", "", "", "2006", "current", "4", "1", "2", "1", "0", "", "", "1", "3", "2", "26.4", "44", "", "", "86.6", "74.9", "", "54.7", "", "2", "", "", "201", "1", "1", "230", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.1", "88.4", "", "", "", "", "87.9"]} -{"pcdb_id": 15145, "brand_name": "Mistral", "model_name": "OD4 SS 120/150", "model_qualifier": "", "winter_efficiency_pct": 86.6, "summer_efficiency_pct": 74.9, "comparative_hot_water_efficiency_pct": 54.7, "output_kw_max": 44.0, "final_year_of_manufacture": null, "raw": ["015145", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "OD4 SS 120/150", "", "", "2006", "current", "4", "1", "2", "1", "0", "", "", "1", "3", "2", "35.2", "44", "", "", "86.6", "74.9", "", "54.7", "", "2", "", "", "201", "1", "1", "230", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.1", "88.4", "", "", "", "", "87.9"]} -{"pcdb_id": 15146, "brand_name": "Mistral", "model_name": "OD3 SS 90/120", "model_qualifier": "", "winter_efficiency_pct": 86.6, "summer_efficiency_pct": 74.9, "comparative_hot_water_efficiency_pct": 54.7, "output_kw_max": 35.2, "final_year_of_manufacture": null, "raw": ["015146", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "OD3 SS 90/120", "", "", "2006", "current", "4", "1", "2", "1", "0", "", "", "1", "3", "2", "26.4", "35.2", "", "", "86.6", "74.9", "", "54.7", "", "2", "", "", "201", "1", "1", "230", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.1", "88.4", "", "", "", "", "87.9"]} -{"pcdb_id": 15147, "brand_name": "Mistral", "model_name": "OD SS 90/150 Contract", "model_qualifier": "", "winter_efficiency_pct": 86.6, "summer_efficiency_pct": 74.9, "comparative_hot_water_efficiency_pct": 54.7, "output_kw_max": 44.0, "final_year_of_manufacture": null, "raw": ["015147", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "OD SS 90/150 Contract", "", "", "2006", "current", "4", "1", "2", "1", "0", "", "", "1", "3", "2", "26.4", "44", "", "", "86.6", "74.9", "", "54.7", "", "2", "", "", "201", "1", "1", "230", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.1", "88.4", "", "", "", "", "87.9"]} -{"pcdb_id": 15148, "brand_name": "Mistral", "model_name": "SS 90/150 Contract", "model_qualifier": "", "winter_efficiency_pct": 86.6, "summer_efficiency_pct": 74.9, "comparative_hot_water_efficiency_pct": 54.7, "output_kw_max": 44.0, "final_year_of_manufacture": null, "raw": ["015148", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "SS 90/150 Contract", "", "", "2006", "current", "4", "1", "1", "1", "0", "", "", "1", "3", "2", "26.4", "44", "", "", "86.6", "74.9", "", "54.7", "", "2", "", "", "201", "1", "1", "230", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.1", "88.4", "", "", "", "", "87.9"]} -{"pcdb_id": 15149, "brand_name": "Mistral", "model_name": "S3 90/120", "model_qualifier": "", "winter_efficiency_pct": 86.6, "summer_efficiency_pct": 74.9, "comparative_hot_water_efficiency_pct": 54.7, "output_kw_max": 35.2, "final_year_of_manufacture": null, "raw": ["015149", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "S3 90/120", "", "", "2006", "current", "4", "1", "1", "1", "0", "", "", "1", "3", "2", "26.4", "35.2", "", "", "86.6", "74.9", "", "54.7", "", "2", "", "", "201", "1", "1", "230", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.1", "88.4", "", "", "", "", "87.9"]} -{"pcdb_id": 15150, "brand_name": "Mistral", "model_name": "S4 120/150", "model_qualifier": "", "winter_efficiency_pct": 86.6, "summer_efficiency_pct": 74.9, "comparative_hot_water_efficiency_pct": 54.7, "output_kw_max": 44.0, "final_year_of_manufacture": null, "raw": ["015150", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "S4 120/150", "", "", "2006", "current", "4", "1", "1", "1", "0", "", "", "1", "3", "2", "35.2", "44", "", "", "86.6", "74.9", "", "54.7", "", "2", "", "", "201", "1", "1", "230", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.1", "88.4", "", "", "", "", "87.9"]} -{"pcdb_id": 15151, "brand_name": "Mistral", "model_name": "KUT 90/150 Contract", "model_qualifier": "", "winter_efficiency_pct": 86.6, "summer_efficiency_pct": 74.9, "comparative_hot_water_efficiency_pct": 54.7, "output_kw_max": 44.0, "final_year_of_manufacture": null, "raw": ["015151", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "KUT 90/150 Contract", "", "", "2006", "current", "4", "1", "1", "1", "0", "", "", "1", "3", "2", "35.2", "44", "", "", "86.6", "74.9", "", "54.7", "", "2", "", "", "201", "1", "1", "230", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.1", "88.4", "", "", "", "", "87.9"]} -{"pcdb_id": 15152, "brand_name": "Mistral", "model_name": "KUT3 90/120", "model_qualifier": "", "winter_efficiency_pct": 86.6, "summer_efficiency_pct": 74.9, "comparative_hot_water_efficiency_pct": 54.7, "output_kw_max": 35.2, "final_year_of_manufacture": null, "raw": ["015152", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "KUT3 90/120", "", "", "2006", "current", "4", "1", "1", "1", "0", "", "", "1", "3", "2", "26.4", "35.2", "", "", "86.6", "74.9", "", "54.7", "", "2", "", "", "201", "1", "1", "230", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.1", "88.4", "", "", "", "", "87.9"]} -{"pcdb_id": 15153, "brand_name": "Mistral", "model_name": "KUT4 120/150", "model_qualifier": "", "winter_efficiency_pct": 86.6, "summer_efficiency_pct": 74.9, "comparative_hot_water_efficiency_pct": 54.7, "output_kw_max": 44.0, "final_year_of_manufacture": null, "raw": ["015153", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "KUT4 120/150", "", "", "2006", "current", "4", "1", "1", "1", "0", "", "", "1", "3", "2", "35.2", "44", "", "", "86.6", "74.9", "", "54.7", "", "2", "", "", "201", "1", "1", "230", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.1", "88.4", "", "", "", "", "87.9"]} -{"pcdb_id": 15154, "brand_name": "Mistral", "model_name": "C3 90/120 Standard", "model_qualifier": "", "winter_efficiency_pct": 86.6, "summer_efficiency_pct": 74.9, "comparative_hot_water_efficiency_pct": 54.7, "output_kw_max": 35.2, "final_year_of_manufacture": null, "raw": ["015154", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "C3 90/120 Standard", "", "", "2006", "current", "4", "1", "1", "1", "0", "", "", "1", "3", "2", "26.4", "35.2", "", "", "86.6", "74.9", "", "54.7", "", "2", "", "", "201", "1", "1", "230", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.1", "88.4", "", "", "", "", "87.9"]} -{"pcdb_id": 15155, "brand_name": "Mistral", "model_name": "C 90/150 Contract", "model_qualifier": "", "winter_efficiency_pct": 84.7, "summer_efficiency_pct": 76.6, "comparative_hot_water_efficiency_pct": 46.1, "output_kw_max": 44.0, "final_year_of_manufacture": null, "raw": ["015155", "000056", "0", "2024/Jan/31 10:17", "Mistral Boilers", "Mistral", "C 90/150 Contract", "", "", "2006", "current", "4", "1", "1", "2", "0", "", "", "1", "3", "2", "26.4", "44", "", "", "84.7", "76.6", "", "46.1", "", "2", "", "", "203", "1", "1", "230", "0", "2", "", "0", "60", "0", "25", "1", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.1", "88.4", "", "", "", "", "87.9"]} -{"pcdb_id": 15156, "brand_name": "Mistral", "model_name": "C4 120/150 Standard", "model_qualifier": "", "winter_efficiency_pct": 84.7, "summer_efficiency_pct": 76.6, "comparative_hot_water_efficiency_pct": 46.1, "output_kw_max": 44.0, "final_year_of_manufacture": null, "raw": ["015156", "000056", "0", "2024/Jan/31 10:17", "Mistral Boilers", "Mistral", "C4 120/150 Standard", "", "", "2006", "current", "4", "1", "1", "2", "0", "", "", "1", "3", "2", "35.2", "44", "", "", "84.7", "76.6", "", "46.1", "", "2", "", "", "203", "1", "1", "230", "0", "2", "", "0", "60", "0", "25", "1", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.1", "88.4", "", "", "", "", "87.9"]} -{"pcdb_id": 15157, "brand_name": "Mistral", "model_name": "C4 120/150 Plus", "model_qualifier": "", "winter_efficiency_pct": 84.7, "summer_efficiency_pct": 76.6, "comparative_hot_water_efficiency_pct": 46.1, "output_kw_max": 44.0, "final_year_of_manufacture": null, "raw": ["015157", "000056", "0", "2024/Jan/31 10:17", "Mistral Boilers", "Mistral", "C4 120/150 Plus", "", "", "2006", "current", "4", "1", "1", "2", "0", "", "", "1", "3", "2", "35.2", "44", "", "", "84.7", "76.6", "", "46.1", "", "2", "", "", "203", "1", "1", "230", "0", "2", "", "0", "60", "0", "25", "1", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.1", "88.4", "", "", "", "", "87.9"]} -{"pcdb_id": 15158, "brand_name": "Mistral", "model_name": "C 90/150 Plus Contract", "model_qualifier": "", "winter_efficiency_pct": 84.7, "summer_efficiency_pct": 76.6, "comparative_hot_water_efficiency_pct": 46.1, "output_kw_max": 44.0, "final_year_of_manufacture": null, "raw": ["015158", "000056", "0", "2024/Jan/31 10:17", "Mistral Boilers", "Mistral", "C 90/150 Plus Contract", "", "", "2006", "current", "4", "1", "1", "2", "0", "", "", "1", "3", "2", "26.4", "44", "", "", "84.7", "76.6", "", "46.1", "", "2", "", "", "203", "1", "1", "230", "0", "2", "", "0", "60", "0", "25", "1", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.1", "88.4", "", "", "", "", "87.9"]} -{"pcdb_id": 15159, "brand_name": "Mistral", "model_name": "C3 90/120 Plus", "model_qualifier": "", "winter_efficiency_pct": 84.7, "summer_efficiency_pct": 76.6, "comparative_hot_water_efficiency_pct": 46.1, "output_kw_max": 35.2, "final_year_of_manufacture": null, "raw": ["015159", "000056", "0", "2024/Jan/31 10:17", "Mistral Boilers", "Mistral", "C3 90/120 Plus", "", "", "2006", "current", "4", "1", "1", "2", "0", "", "", "1", "3", "2", "26.4", "35.2", "", "", "84.7", "76.6", "", "46.1", "", "2", "", "", "203", "1", "1", "230", "0", "2", "", "0", "60", "0", "25", "1", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.1", "88.4", "", "", "", "", "87.9"]} -{"pcdb_id": 15160, "brand_name": "Mistral", "model_name": "BH3 90/120", "model_qualifier": "", "winter_efficiency_pct": 86.6, "summer_efficiency_pct": 74.9, "comparative_hot_water_efficiency_pct": 54.7, "output_kw_max": 35.2, "final_year_of_manufacture": null, "raw": ["015160", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "BH3 90/120", "", "", "2006", "current", "4", "1", "1", "1", "0", "", "", "1", "3", "2", "26.4", "35.2", "", "", "86.6", "74.9", "", "54.7", "", "2", "", "", "201", "1", "1", "230", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.1", "88.4", "", "", "", "", "87.9"]} -{"pcdb_id": 15161, "brand_name": "Mistral", "model_name": "BH4 120/150", "model_qualifier": "", "winter_efficiency_pct": 86.6, "summer_efficiency_pct": 74.9, "comparative_hot_water_efficiency_pct": 54.7, "output_kw_max": 44.0, "final_year_of_manufacture": null, "raw": ["015161", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "BH4 120/150", "", "", "2006", "current", "4", "1", "1", "1", "0", "", "", "1", "3", "2", "35.2", "44", "", "", "86.6", "74.9", "", "54.7", "", "2", "", "", "201", "1", "1", "230", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.1", "88.4", "", "", "", "", "87.9"]} -{"pcdb_id": 15162, "brand_name": "Mistral", "model_name": "BH 90/150 Contract", "model_qualifier": "", "winter_efficiency_pct": 86.6, "summer_efficiency_pct": 74.9, "comparative_hot_water_efficiency_pct": 54.7, "output_kw_max": 44.0, "final_year_of_manufacture": null, "raw": ["015162", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "BH 90/150 Contract", "", "", "2006", "current", "4", "1", "1", "1", "0", "", "", "1", "3", "2", "26.4", "44", "", "", "86.6", "74.9", "", "54.7", "", "2", "", "", "201", "1", "1", "230", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.1", "88.4", "", "", "", "", "87.9"]} -{"pcdb_id": 15163, "brand_name": "Glow-worm", "model_name": "Betacom 24", "model_qualifier": "", "winter_efficiency_pct": 85.3, "summer_efficiency_pct": 76.7, "comparative_hot_water_efficiency_pct": 53.9, "output_kw_max": 24.9, "final_year_of_manufacture": 2013, "raw": ["015163", "000207", "0", "2013/Aug/23 09:29", "Vaillant Group UK", "Glow-worm", "Betacom 24", "", "47-019-04", "2006", "2013", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.9", "24.9", "", "", "85.3", "76.7", "", "53.9", "", "2", "", "", "104", "1", "2", "145", "15", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "89.9", "", "", "", "", "89.5"]} -{"pcdb_id": 15164, "brand_name": "Glow-worm", "model_name": "Betacom 30", "model_qualifier": "", "winter_efficiency_pct": 85.6, "summer_efficiency_pct": 77.0, "comparative_hot_water_efficiency_pct": 54.2, "output_kw_max": 28.6, "final_year_of_manufacture": 2013, "raw": ["015164", "000207", "0", "2013/Aug/23 09:30", "Vaillant Group UK", "Glow-worm", "Betacom 30", "", "47-019-05", "2006", "2013", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28.6", "28.6", "", "", "85.6", "77.0", "", "54.2", "", "2", "", "", "104", "1", "2", "150", "20", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.5", "91.0", "", "", "", "", "90.3"]} -{"pcdb_id": 15165, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "42 CDi", "winter_efficiency_pct": 89.8, "summer_efficiency_pct": 81.2, "comparative_hot_water_efficiency_pct": 63.4, "output_kw_max": 30.0, "final_year_of_manufacture": 2012, "raw": ["015165", "000035", "0", "2020/Sep/08 09:27", "Worcester Bosch Group", "Worcester", "Greenstar", "42 CDi", "47-406-11", "2006", "2012", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "30", "30", "", "", "89.8", "81.2", "", "63.4", "", "2", "1", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "", "0305", "", "", "", "", "", "", "", "", "90.1", "101.0", "", "", "", "", "99.0"]} -{"pcdb_id": 15166, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "42 CDi", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 62.6, "output_kw_max": 30.0, "final_year_of_manufacture": 2012, "raw": ["015166", "000035", "0", "2020/Sep/08 09:27", "Worcester Bosch Group", "Worcester", "Greenstar", "42 CDi", "47-406-10", "2006", "2012", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "30", "30", "", "", "88.8", "80.2", "", "62.6", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "", "0305", "", "", "", "", "", "", "", "", "88.1", "98.8", "", "", "", "", "96.8"]} -{"pcdb_id": 15168, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "37 CDi", "winter_efficiency_pct": 89.8, "summer_efficiency_pct": 81.2, "comparative_hot_water_efficiency_pct": 57.1, "output_kw_max": 30.0, "final_year_of_manufacture": 2012, "raw": ["015168", "000035", "0", "2020/Sep/08 09:27", "Worcester Bosch Group", "Worcester", "Greenstar", "37 CDi", "47-406-09", "2006", "2012", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "30", "30", "", "", "89.8", "81.2", "", "57.1", "", "2", "1", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0305", "", "", "", "", "", "", "", "", "90.1", "101.0", "", "", "", "", "99.0"]} -{"pcdb_id": 15169, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "37 CDi", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 56.4, "output_kw_max": 30.0, "final_year_of_manufacture": 2012, "raw": ["015169", "000035", "0", "2020/Sep/08 09:28", "Worcester Bosch Group", "Worcester", "Greenstar", "37 CDi", "47-406-08", "2006", "2012", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "30", "30", "", "", "88.8", "80.2", "", "56.4", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0305", "", "", "", "", "", "", "", "", "88.1", "98.8", "", "", "", "", "96.8"]} -{"pcdb_id": 15170, "brand_name": "Sime", "model_name": "Ecomfort", "model_qualifier": "25 HE", "winter_efficiency_pct": 86.3, "summer_efficiency_pct": 77.7, "comparative_hot_water_efficiency_pct": 54.7, "output_kw_max": 24.7, "final_year_of_manufacture": 2018, "raw": ["015170", "000213", "0", "2018/Feb/26 16:40", "Fonderie Sime S.p.A.", "Sime", "Ecomfort", "25 HE", "", "2006", "2018", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "24.7", "24.7", "", "", "86.3", "77.7", "", "54.7", "", "2", "", "", "104", "1", "2", "180", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.4", "92.8", "", "", "", "", "91.8"]} -{"pcdb_id": 15171, "brand_name": "Sime", "model_name": "Ecomfort", "model_qualifier": "25 HE", "winter_efficiency_pct": 87.3, "summer_efficiency_pct": 78.7, "comparative_hot_water_efficiency_pct": 55.3, "output_kw_max": 24.7, "final_year_of_manufacture": 2018, "raw": ["015171", "000213", "0", "2018/Feb/26 16:40", "Fonderie Sime S.p.A.", "Sime", "Ecomfort", "25 HE", "", "2006", "2018", "2", "2", "1", "2", "0", "", "", "2", "3", "2", "24.7", "24.7", "", "", "87.3", "78.7", "", "55.3", "", "2", "1", "", "104", "1", "2", "180", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.3", "94.9", "", "", "", "", "93.8"]} -{"pcdb_id": 15172, "brand_name": "Ravenheat", "model_name": "CSI Primary AAA", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 22.3, "final_year_of_manufacture": null, "raw": ["015172", "000026", "0", "2012/Mar/27 10:12", "Ravenheat Manufacturing", "Ravenheat", "CSI Primary AAA", "", "", "2006", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "22.3", "22.3", "", "", "88.6", "79.6", "", "58.1", "", "2", "1", "", "102", "1", "2", "160", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.9", "97.5", "", "", "", "", "96.3"]} -{"pcdb_id": 15173, "brand_name": "Ravenheat", "model_name": "CSI Primary AAA", "model_qualifier": "", "winter_efficiency_pct": 87.6, "summer_efficiency_pct": 78.6, "comparative_hot_water_efficiency_pct": 57.4, "output_kw_max": 22.3, "final_year_of_manufacture": null, "raw": ["015173", "000026", "0", "2012/Mar/27 10:12", "Ravenheat Manufacturing", "Ravenheat", "CSI Primary AAA", "", "", "2006", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "22.3", "22.3", "", "", "87.6", "78.6", "", "57.4", "", "2", "", "", "102", "1", "2", "160", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.9", "95.4", "", "", "", "", "94.2"]} -{"pcdb_id": 15174, "brand_name": "Ravenheat", "model_name": "HE Primary AAA", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 22.3, "final_year_of_manufacture": null, "raw": ["015174", "000026", "0", "2012/Mar/27 10:12", "Ravenheat Manufacturing", "Ravenheat", "HE Primary AAA", "", "", "2006", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "22.3", "22.3", "", "", "88.6", "79.6", "", "58.1", "", "2", "1", "", "102", "1", "2", "160", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.9", "97.5", "", "", "", "", "96.3"]} -{"pcdb_id": 15175, "brand_name": "Ravenheat", "model_name": "HE Primary AAA", "model_qualifier": "", "winter_efficiency_pct": 87.6, "summer_efficiency_pct": 78.6, "comparative_hot_water_efficiency_pct": 57.4, "output_kw_max": 22.3, "final_year_of_manufacture": null, "raw": ["015175", "000026", "0", "2012/Mar/27 10:12", "Ravenheat Manufacturing", "Ravenheat", "HE Primary AAA", "", "", "2006", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "22.3", "22.3", "", "", "87.6", "78.6", "", "57.4", "", "2", "", "", "102", "1", "2", "160", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.9", "95.4", "", "", "", "", "94.2"]} -{"pcdb_id": 15176, "brand_name": "Ravenheat", "model_name": "HE System AAA T", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 22.3, "final_year_of_manufacture": null, "raw": ["015176", "000026", "0", "2012/Mar/27 10:12", "Ravenheat Manufacturing", "Ravenheat", "HE System AAA T", "", "", "2006", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "22.3", "22.3", "", "", "88.6", "79.6", "", "58.1", "", "2", "1", "", "102", "1", "2", "160", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.9", "97.5", "", "", "", "", "96.3"]} -{"pcdb_id": 15177, "brand_name": "Ravenheat", "model_name": "HE System AAA T", "model_qualifier": "", "winter_efficiency_pct": 87.6, "summer_efficiency_pct": 78.6, "comparative_hot_water_efficiency_pct": 57.4, "output_kw_max": 22.3, "final_year_of_manufacture": null, "raw": ["015177", "000026", "0", "2012/Mar/27 10:12", "Ravenheat Manufacturing", "Ravenheat", "HE System AAA T", "", "", "2006", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "22.3", "22.3", "", "", "87.6", "78.6", "", "57.4", "", "2", "", "", "102", "1", "2", "160", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.9", "95.4", "", "", "", "", "94.2"]} -{"pcdb_id": 15178, "brand_name": "Ravenheat", "model_name": "HE System AAA", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 22.3, "final_year_of_manufacture": null, "raw": ["015178", "000026", "0", "2012/Mar/27 10:12", "Ravenheat Manufacturing", "Ravenheat", "HE System AAA", "", "", "2006", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "22.3", "22.3", "", "", "88.6", "79.6", "", "58.1", "", "2", "1", "", "102", "1", "2", "160", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.9", "97.5", "", "", "", "", "96.3"]} -{"pcdb_id": 15179, "brand_name": "Ravenheat", "model_name": "HE System AAA", "model_qualifier": "", "winter_efficiency_pct": 87.6, "summer_efficiency_pct": 78.6, "comparative_hot_water_efficiency_pct": 57.4, "output_kw_max": 22.3, "final_year_of_manufacture": null, "raw": ["015179", "000026", "0", "2012/Mar/27 10:12", "Ravenheat Manufacturing", "Ravenheat", "HE System AAA", "", "", "2006", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "22.3", "22.3", "", "", "87.6", "78.6", "", "57.4", "", "2", "", "", "102", "1", "2", "160", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.9", "95.4", "", "", "", "", "94.2"]} -{"pcdb_id": 15180, "brand_name": "Ravenheat", "model_name": "CSI System AAA T", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 22.3, "final_year_of_manufacture": null, "raw": ["015180", "000026", "0", "2012/Mar/27 10:12", "Ravenheat Manufacturing", "Ravenheat", "CSI System AAA T", "", "", "2006", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "22.3", "22.3", "", "", "88.6", "79.6", "", "58.1", "", "2", "1", "", "102", "1", "2", "160", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.9", "97.5", "", "", "", "", "96.3"]} -{"pcdb_id": 15181, "brand_name": "Ravenheat", "model_name": "CSI System AAA T", "model_qualifier": "", "winter_efficiency_pct": 87.6, "summer_efficiency_pct": 78.6, "comparative_hot_water_efficiency_pct": 57.4, "output_kw_max": 22.3, "final_year_of_manufacture": null, "raw": ["015181", "000026", "0", "2012/Mar/27 10:12", "Ravenheat Manufacturing", "Ravenheat", "CSI System AAA T", "", "", "2006", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "22.3", "22.3", "", "", "87.6", "78.6", "", "57.4", "", "2", "", "", "102", "1", "2", "160", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.9", "95.4", "", "", "", "", "94.2"]} -{"pcdb_id": 15182, "brand_name": "Ravenheat", "model_name": "CSI System AAA", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 22.3, "final_year_of_manufacture": null, "raw": ["015182", "000026", "0", "2012/Mar/27 10:12", "Ravenheat Manufacturing", "Ravenheat", "CSI System AAA", "", "", "2006", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "22.3", "22.3", "", "", "88.6", "79.6", "", "58.1", "", "2", "1", "", "102", "1", "2", "160", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.9", "97.5", "", "", "", "", "96.3"]} -{"pcdb_id": 15183, "brand_name": "Ravenheat", "model_name": "CSI System AAA", "model_qualifier": "", "winter_efficiency_pct": 87.6, "summer_efficiency_pct": 78.6, "comparative_hot_water_efficiency_pct": 57.4, "output_kw_max": 22.3, "final_year_of_manufacture": null, "raw": ["015183", "000026", "0", "2012/Mar/27 10:12", "Ravenheat Manufacturing", "Ravenheat", "CSI System AAA", "", "", "2006", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "22.3", "22.3", "", "", "87.6", "78.6", "", "57.4", "", "2", "", "", "102", "1", "2", "160", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.9", "95.4", "", "", "", "", "94.2"]} -{"pcdb_id": 15184, "brand_name": "Ravenheat", "model_name": "HE 85 AAA", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 56.3, "output_kw_max": 22.3, "final_year_of_manufacture": null, "raw": ["015184", "000026", "0", "2010/Sep/29 12:23", "Ravenheat Manufacturing", "Ravenheat", "HE 85 AAA", "", "", "2006", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "22.3", "22.3", "", "", "88.6", "80.0", "", "56.3", "", "2", "1", "", "104", "1", "2", "160", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.9", "97.5", "", "", "", "", "96.3"]} -{"pcdb_id": 15185, "brand_name": "Ravenheat", "model_name": "HE 85 AAA", "model_qualifier": "", "winter_efficiency_pct": 87.6, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 55.6, "output_kw_max": 22.3, "final_year_of_manufacture": null, "raw": ["015185", "000026", "0", "2010/Sep/29 12:18", "Ravenheat Manufacturing", "Ravenheat", "HE 85 AAA", "", "", "2006", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "22.3", "22.3", "", "", "87.6", "79.0", "", "55.6", "", "2", "", "", "104", "1", "2", "160", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.9", "95.4", "", "", "", "", "94.2"]} -{"pcdb_id": 15186, "brand_name": "Ravenheat", "model_name": "HE 85 AAAT", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 56.3, "output_kw_max": 22.3, "final_year_of_manufacture": null, "raw": ["015186", "000026", "0", "2010/Sep/29 12:23", "Ravenheat Manufacturing", "Ravenheat", "HE 85 AAAT", "", "", "2006", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "22.3", "22.3", "", "", "88.6", "80.0", "", "56.3", "", "2", "1", "", "104", "1", "2", "160", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.9", "97.5", "", "", "", "", "96.3"]} -{"pcdb_id": 15187, "brand_name": "Ravenheat", "model_name": "HE 85 AAAT", "model_qualifier": "", "winter_efficiency_pct": 87.6, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 55.6, "output_kw_max": 22.3, "final_year_of_manufacture": null, "raw": ["015187", "000026", "0", "2010/Sep/29 12:18", "Ravenheat Manufacturing", "Ravenheat", "HE 85 AAAT", "", "", "2006", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "22.3", "22.3", "", "", "87.6", "79.0", "", "55.6", "", "2", "", "", "104", "1", "2", "160", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.9", "95.4", "", "", "", "", "94.2"]} -{"pcdb_id": 15188, "brand_name": "Ravenheat", "model_name": "CSI 85 AAAT", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 56.3, "output_kw_max": 22.3, "final_year_of_manufacture": null, "raw": ["015188", "000026", "0", "2010/Sep/29 12:24", "Ravenheat Manufacturing", "Ravenheat", "CSI 85 AAAT", "", "", "2006", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "22.3", "22.3", "", "", "88.6", "80.0", "", "56.3", "", "2", "1", "", "104", "1", "2", "160", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.9", "97.5", "", "", "", "", "96.3"]} -{"pcdb_id": 15189, "brand_name": "Ravenheat", "model_name": "CSI 85 AAAT", "model_qualifier": "", "winter_efficiency_pct": 87.6, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 55.6, "output_kw_max": 22.3, "final_year_of_manufacture": null, "raw": ["015189", "000026", "0", "2010/Sep/29 12:18", "Ravenheat Manufacturing", "Ravenheat", "CSI 85 AAAT", "", "", "2006", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "22.3", "22.3", "", "", "87.6", "79.0", "", "55.6", "", "2", "", "", "104", "1", "2", "160", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.9", "95.4", "", "", "", "", "94.2"]} -{"pcdb_id": 15190, "brand_name": "Ravenheat", "model_name": "CSI 85 AAA", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 56.3, "output_kw_max": 22.3, "final_year_of_manufacture": null, "raw": ["015190", "000026", "0", "2010/Sep/29 12:24", "Ravenheat Manufacturing", "Ravenheat", "CSI 85 AAA", "", "", "2006", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "22.3", "22.3", "", "", "88.6", "80.0", "", "56.3", "", "2", "1", "", "104", "1", "2", "160", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.9", "97.5", "", "", "", "", "96.3"]} -{"pcdb_id": 15191, "brand_name": "Ravenheat", "model_name": "CSI 85 AAA", "model_qualifier": "", "winter_efficiency_pct": 87.6, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 55.6, "output_kw_max": 22.3, "final_year_of_manufacture": null, "raw": ["015191", "000026", "0", "2010/Sep/29 12:20", "Ravenheat Manufacturing", "Ravenheat", "CSI 85 AAA", "", "", "2006", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "22.3", "22.3", "", "", "87.6", "79.0", "", "55.6", "", "2", "", "", "104", "1", "2", "160", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.9", "95.4", "", "", "", "", "94.2"]} -{"pcdb_id": 15193, "brand_name": "Ferroli", "model_name": "Optimax", "model_qualifier": "HE 38 C", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 56.3, "output_kw_max": 30.2, "final_year_of_manufacture": 2008, "raw": ["015193", "000097", "0", "2010/Sep/29 12:21", "Ferroli SpA", "Ferroli", "Optimax", "HE 38 C", "", "2006", "2008", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "30.2", "30.2", "", "", "88.7", "80.1", "", "56.3", "", "2", "", "", "104", "1", "2", "145", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.7", "98.3", "", "", "", "", "96.5"]} -{"pcdb_id": 15194, "brand_name": "Ferroli", "model_name": "Optimax", "model_qualifier": "HE 25 S", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 24.6, "final_year_of_manufacture": 2008, "raw": ["015194", "000097", "0", "2012/Mar/27 10:12", "Ferroli SpA", "Ferroli", "Optimax", "HE 25 S", "", "2006", "2008", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24.6", "24.6", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "120", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.6", "97.6", "", "", "", "", "95.9"]} -{"pcdb_id": 15195, "brand_name": "Ferroli", "model_name": "Optimax", "model_qualifier": "HE 31 C", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 56.1, "output_kw_max": 24.6, "final_year_of_manufacture": 2008, "raw": ["015195", "000097", "0", "2009/Apr/28 16:02", "Ferroli SpA", "Ferroli", "Optimax", "HE 31 C", "", "2006", "2008", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.6", "24.6", "", "", "88.4", "79.8", "", "56.1", "", "2", "", "", "104", "1", "2", "135", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.6", "97.6", "", "", "", "", "95.9"]} -{"pcdb_id": 15198, "brand_name": "Glow-worm", "model_name": "Ultrapower 100 SXI", "model_qualifier": "", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 80.9, "comparative_hot_water_efficiency_pct": 54.5, "output_kw_max": 24.3, "final_year_of_manufacture": null, "raw": ["015198", "000207", "0", "2024/Jan/31 10:17", "Vaillant Group UK", "Glow-worm", "Ultrapower 100 SXI", "", "41-019-09", "2007", "current", "1", "1", "1", "2", "0", "", "", "2", "2", "2", "24.3", "24.3", "", "", "88.2", "80.9", "", "54.5", "", "2", "", "", "106", "1", "2", "180", "15", "2", "1", "0", "80", "0", "50", "5", "62", "0.57", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.0", "96.4", "", "", "", "", "95.2"]} -{"pcdb_id": 15199, "brand_name": "Glow-worm", "model_name": "Ultrapower 170 SXI", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 51.3, "output_kw_max": 24.3, "final_year_of_manufacture": null, "raw": ["015199", "000207", "0", "2024/Jan/31 10:17", "Vaillant Group UK", "Glow-worm", "Ultrapower 170 SXI", "", "41-019-10", "2007", "current", "1", "1", "1", "2", "0", "", "", "2", "2", "2", "24.3", "24.3", "", "", "88.3", "81.0", "", "51.3", "", "2", "", "", "106", "1", "2", "180", "15", "2", "1", "0", "120", "0", "50", "5", "62", "0.57", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.0", "96.8", "", "", "", "", "95.5"]} -{"pcdb_id": 15200, "brand_name": "Biasi", "model_name": "Riva Compact HE", "model_qualifier": "M96.24SM/C2", "winter_efficiency_pct": 85.8, "summer_efficiency_pct": 77.2, "comparative_hot_water_efficiency_pct": 54.3, "output_kw_max": 24.6, "final_year_of_manufacture": null, "raw": ["015200", "000208", "0", "2007/Jun/22 10:59", "Biasi SpA", "Biasi", "Riva Compact HE", "M96.24SM/C2", "47-583-05", "2006", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.6", "24.6", "", "", "85.8", "77.2", "", "54.3", "", "2", "", "", "104", "1", "2", "140", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.7", "90.9", "", "", "", "", "90.5"]} -{"pcdb_id": 15201, "brand_name": "Biasi", "model_name": "Riva Compact HE", "model_qualifier": "M96.24SM/C2", "winter_efficiency_pct": 86.2, "summer_efficiency_pct": 77.6, "comparative_hot_water_efficiency_pct": 54.5, "output_kw_max": 23.7, "final_year_of_manufacture": null, "raw": ["015201", "000208", "0", "2007/Jun/22 11:01", "Biasi SpA", "Biasi", "Riva Compact HE", "M96.24SM/C2", "", "2006", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "23.7", "23.7", "", "", "86.2", "77.6", "", "54.5", "", "2", "0", "", "104", "1", "2", "140", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.3", "90.8", "", "", "", "", "90.1"]} -{"pcdb_id": 15202, "brand_name": "Biasi", "model_name": "Garda HE", "model_qualifier": "M96.28SM/D2", "winter_efficiency_pct": 85.9, "summer_efficiency_pct": 77.3, "comparative_hot_water_efficiency_pct": 54.4, "output_kw_max": 28.3, "final_year_of_manufacture": null, "raw": ["015202", "000208", "0", "2007/Jun/22 10:38", "Biasi SpA", "Biasi", "Garda HE", "M96.28SM/D2", "", "2006", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28.3", "28.3", "", "", "85.9", "77.3", "", "54.4", "", "2", "", "", "104", "1", "2", "150", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "91.5", "", "", "", "", "90.8"]} -{"pcdb_id": 15203, "brand_name": "Biasi", "model_name": "Garda HE", "model_qualifier": "M96.28SM/D2", "winter_efficiency_pct": 86.3, "summer_efficiency_pct": 77.7, "comparative_hot_water_efficiency_pct": 54.6, "output_kw_max": 27.4, "final_year_of_manufacture": 2007, "raw": ["015203", "000208", "0", "2008/May/22 11:56", "Biasi SpA", "Biasi", "Garda HE", "M96.28SM/D2", "", "2006", "2007", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "27.4", "27.4", "", "", "86.3", "77.7", "", "54.6", "", "2", "0", "", "104", "1", "2", "150", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.1", "91.4", "", "", "", "", "90.6"]} -{"pcdb_id": 15204, "brand_name": "Biasi", "model_name": "Riva Compact HE", "model_qualifier": "M96.28SM/C2", "winter_efficiency_pct": 85.9, "summer_efficiency_pct": 77.3, "comparative_hot_water_efficiency_pct": 54.4, "output_kw_max": 28.3, "final_year_of_manufacture": null, "raw": ["015204", "000208", "0", "2007/Jun/22 10:51", "Biasi SpA", "Biasi", "Riva Compact HE", "M96.28SM/C2", "47-583-06", "2006", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28.3", "28.3", "", "", "85.9", "77.3", "", "54.4", "", "2", "", "", "104", "1", "2", "150", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "91.5", "", "", "", "", "90.8"]} -{"pcdb_id": 15205, "brand_name": "Biasi", "model_name": "Riva Compact HE", "model_qualifier": "M96.28SM/C2", "winter_efficiency_pct": 86.3, "summer_efficiency_pct": 77.7, "comparative_hot_water_efficiency_pct": 54.6, "output_kw_max": 27.4, "final_year_of_manufacture": null, "raw": ["015205", "000208", "0", "2007/Jun/22 10:52", "Biasi SpA", "Biasi", "Riva Compact HE", "M96.28SM/C2", "", "2006", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "27.4", "27.4", "", "", "86.3", "77.7", "", "54.6", "", "2", "0", "", "104", "1", "2", "150", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.1", "91.4", "", "", "", "", "90.6"]} -{"pcdb_id": 15206, "brand_name": "Biasi", "model_name": "Garda HE", "model_qualifier": "M96.28SM/B2", "winter_efficiency_pct": 85.9, "summer_efficiency_pct": 77.3, "comparative_hot_water_efficiency_pct": 54.4, "output_kw_max": 28.3, "final_year_of_manufacture": null, "raw": ["015206", "000208", "0", "2007/Jun/22 10:37", "Biasi SpA", "Biasi", "Garda HE", "M96.28SM/B2", "", "2006", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28.3", "28.3", "", "", "85.9", "77.3", "", "54.4", "", "2", "", "", "104", "1", "2", "150", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "91.5", "", "", "", "", "90.8"]} -{"pcdb_id": 15207, "brand_name": "Biasi", "model_name": "Garda HE", "model_qualifier": "M96.28SM/B2", "winter_efficiency_pct": 86.3, "summer_efficiency_pct": 77.7, "comparative_hot_water_efficiency_pct": 54.6, "output_kw_max": 27.4, "final_year_of_manufacture": null, "raw": ["015207", "000208", "0", "2007/Jun/22 10:38", "Biasi SpA", "Biasi", "Garda HE", "M96.28SM/B2", "", "2006", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "27.4", "27.4", "", "", "86.3", "77.7", "", "54.6", "", "2", "0", "", "104", "1", "2", "150", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.1", "91.4", "", "", "", "", "90.6"]} -{"pcdb_id": 15208, "brand_name": "Biasi", "model_name": "Garda HE", "model_qualifier": "M96.24SM/B2", "winter_efficiency_pct": 85.8, "summer_efficiency_pct": 77.2, "comparative_hot_water_efficiency_pct": 54.3, "output_kw_max": 24.6, "final_year_of_manufacture": null, "raw": ["015208", "000208", "0", "2007/Jun/22 10:36", "Biasi SpA", "Biasi", "Garda HE", "M96.24SM/B2", "", "2006", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.6", "24.6", "", "", "85.8", "77.2", "", "54.3", "", "2", "", "", "104", "1", "2", "140", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.7", "90.9", "", "", "", "", "90.5"]} -{"pcdb_id": 15209, "brand_name": "Biasi", "model_name": "Garda HE", "model_qualifier": "M96.24SM/B2", "winter_efficiency_pct": 86.2, "summer_efficiency_pct": 77.6, "comparative_hot_water_efficiency_pct": 54.5, "output_kw_max": 23.7, "final_year_of_manufacture": null, "raw": ["015209", "000208", "0", "2007/Jun/22 10:37", "Biasi SpA", "Biasi", "Garda HE", "M96.24SM/B2", "", "2006", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "23.7", "23.7", "", "", "86.2", "77.6", "", "54.5", "", "2", "0", "", "104", "1", "2", "140", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.3", "90.8", "", "", "", "", "90.1"]} -{"pcdb_id": 15210, "brand_name": "Biasi", "model_name": "Riva Compact HE", "model_qualifier": "M96.28SR/C2", "winter_efficiency_pct": 85.9, "summer_efficiency_pct": 76.9, "comparative_hot_water_efficiency_pct": 56.2, "output_kw_max": 28.3, "final_year_of_manufacture": null, "raw": ["015210", "000208", "0", "2012/Mar/27 10:12", "Biasi SpA", "Biasi", "Riva Compact HE", "M96.28SR/C2", "41-583-02", "2006", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "28.3", "28.3", "", "", "85.9", "76.9", "", "56.2", "", "2", "", "", "102", "1", "2", "150", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "91.5", "", "", "", "", "90.8"]} -{"pcdb_id": 15211, "brand_name": "Biasi", "model_name": "Riva Compact HE", "model_qualifier": "M96.28SR/C2", "winter_efficiency_pct": 86.3, "summer_efficiency_pct": 77.3, "comparative_hot_water_efficiency_pct": 56.5, "output_kw_max": 27.4, "final_year_of_manufacture": null, "raw": ["015211", "000208", "0", "2012/Mar/27 10:12", "Biasi SpA", "Biasi", "Riva Compact HE", "M96.28SR/C2", "", "2006", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "27.4", "27.4", "", "", "86.3", "77.3", "", "56.5", "", "2", "0", "", "102", "1", "2", "150", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.1", "91.4", "", "", "", "", "90.6"]} -{"pcdb_id": 15212, "brand_name": "Biasi", "model_name": "Riva Compact HE", "model_qualifier": "M96.32SM/C2", "winter_efficiency_pct": 85.5, "summer_efficiency_pct": 76.9, "comparative_hot_water_efficiency_pct": 54.1, "output_kw_max": 32.2, "final_year_of_manufacture": null, "raw": ["015212", "000208", "0", "2007/Jun/22 10:52", "Biasi SpA", "Biasi", "Riva Compact HE", "M96.32SM/C2", "47-583-07", "2006", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "32.2", "32.2", "", "", "85.5", "76.9", "", "54.1", "", "2", "", "", "104", "1", "2", "150", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.1", "90.7", "", "", "", "", "90.0"]} -{"pcdb_id": 15213, "brand_name": "Biasi", "model_name": "Riva Compact HE", "model_qualifier": "M96.32SM/C2", "winter_efficiency_pct": 87.4, "summer_efficiency_pct": 78.8, "comparative_hot_water_efficiency_pct": 55.4, "output_kw_max": 32.2, "final_year_of_manufacture": null, "raw": ["015213", "000208", "0", "2007/Jun/22 10:53", "Biasi SpA", "Biasi", "Riva Compact HE", "M96.32SM/C2", "", "2006", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "32.2", "32.2", "", "", "87.4", "78.8", "", "55.4", "", "2", "0", "", "104", "1", "2", "150", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.1", "92.7", "", "", "", "", "92.0"]} -{"pcdb_id": 15214, "brand_name": "Biasi", "model_name": "Garda HE Silver", "model_qualifier": "M96.24SM/D2", "winter_efficiency_pct": 85.8, "summer_efficiency_pct": 77.2, "comparative_hot_water_efficiency_pct": 54.3, "output_kw_max": 24.6, "final_year_of_manufacture": 2008, "raw": ["015214", "000208", "0", "2008/May/22 11:21", "Biasi SpA", "Biasi", "Garda HE Silver", "M96.24SM/D2", "47-583-03B", "2006", "2008", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.6", "24.6", "", "", "85.8", "77.2", "", "54.3", "", "2", "", "", "104", "1", "2", "140", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.7", "90.9", "", "", "", "", "90.5"]} -{"pcdb_id": 15215, "brand_name": "Biasi", "model_name": "Garda HE Silver", "model_qualifier": "M96.24SM/D2", "winter_efficiency_pct": 86.2, "summer_efficiency_pct": 77.6, "comparative_hot_water_efficiency_pct": 54.5, "output_kw_max": 23.7, "final_year_of_manufacture": 2008, "raw": ["015215", "000208", "0", "2008/May/22 11:22", "Biasi SpA", "Biasi", "Garda HE Silver", "M96.24SM/D2", "", "2006", "2008", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "23.7", "23.7", "", "", "86.2", "77.6", "", "54.5", "", "2", "0", "", "104", "1", "2", "140", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.3", "90.8", "", "", "", "", "90.1"]} -{"pcdb_id": 15223, "brand_name": "Worcester", "model_name": "Greenstar Camray", "model_qualifier": "12/18", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 58.7, "output_kw_max": 18.0, "final_year_of_manufacture": 2015, "raw": ["015223", "000035", "0", "2020/Sep/08 09:29", "Worcester Bosch Group", "Worcester", "Greenstar Camray", "12/18", "", "2007", "2015", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "12", "18", "", "", "88.1", "80.3", "", "58.7", "", "2", "", "", "201", "1", "1", "150", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.4", "94.8", "", "", "", "", "94.2"]} -{"pcdb_id": 15224, "brand_name": "Worcester", "model_name": "Greenstar Camray", "model_qualifier": "18/25", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 80.6, "comparative_hot_water_efficiency_pct": 58.9, "output_kw_max": 25.0, "final_year_of_manufacture": 2015, "raw": ["015224", "000035", "0", "2020/Sep/08 09:29", "Worcester Bosch Group", "Worcester", "Greenstar Camray", "18/25", "", "2007", "2015", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "18", "25", "", "", "88.4", "80.6", "", "58.9", "", "2", "", "", "201", "1", "1", "160", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.5", "95.9", "", "", "", "", "94.8"]} -{"pcdb_id": 15225, "brand_name": "Worcester", "model_name": "Greenstar Camray", "model_qualifier": "25/32", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 81.1, "comparative_hot_water_efficiency_pct": 59.3, "output_kw_max": 30.0, "final_year_of_manufacture": 2015, "raw": ["015225", "000035", "0", "2020/Sep/08 09:29", "Worcester Bosch Group", "Worcester", "Greenstar Camray", "25/32", "", "2007", "2015", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "25", "30", "", "", "88.9", "81.1", "", "59.3", "", "2", "", "", "201", "1", "1", "160", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.5", "96.9", "", "", "", "", "95.9"]} -{"pcdb_id": 15226, "brand_name": "Worcester", "model_name": "Greenstar Camray Utility System", "model_qualifier": "12/18", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 58.7, "output_kw_max": 18.0, "final_year_of_manufacture": 2015, "raw": ["015226", "000035", "0", "2020/Sep/08 09:29", "Worcester Bosch Group", "Worcester", "Greenstar Camray Utility System", "12/18", "", "2007", "2015", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "12", "18", "", "", "88.1", "80.3", "", "58.7", "", "2", "", "", "201", "1", "2", "255", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "91.4", "94.8", "", "", "", "", "94.2"]} -{"pcdb_id": 15227, "brand_name": "Worcester", "model_name": "Greenstar Camray Utility System", "model_qualifier": "18/25", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 80.6, "comparative_hot_water_efficiency_pct": 58.9, "output_kw_max": 25.0, "final_year_of_manufacture": 2015, "raw": ["015227", "000035", "0", "2020/Sep/08 09:30", "Worcester Bosch Group", "Worcester", "Greenstar Camray Utility System", "18/25", "", "2007", "2015", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "18", "25", "", "", "88.4", "80.6", "", "58.9", "", "2", "", "", "201", "1", "1", "265", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.5", "95.9", "", "", "", "", "94.8"]} -{"pcdb_id": 15228, "brand_name": "Worcester", "model_name": "Greenstar Camray Utility System", "model_qualifier": "25/32", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 81.1, "comparative_hot_water_efficiency_pct": 59.3, "output_kw_max": 30.0, "final_year_of_manufacture": 2015, "raw": ["015228", "000035", "0", "2020/Sep/08 09:30", "Worcester Bosch Group", "Worcester", "Greenstar Camray Utility System", "25/32", "", "2007", "2015", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "25", "30", "", "", "88.9", "81.1", "", "59.3", "", "2", "", "", "201", "1", "1", "265", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.5", "96.9", "", "", "", "", "95.9"]} -{"pcdb_id": 15229, "brand_name": "Worcester", "model_name": "Greenstar Camray Utility", "model_qualifier": "12/18", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 58.7, "output_kw_max": 18.0, "final_year_of_manufacture": 2015, "raw": ["015229", "000035", "0", "2020/Sep/08 09:30", "Worcester Bosch Group", "Worcester", "Greenstar Camray Utility", "12/18", "", "2007", "2015", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "12", "18", "", "", "88.1", "80.3", "", "58.7", "", "2", "", "", "201", "1", "1", "150", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.4", "94.8", "", "", "", "", "94.2"]} -{"pcdb_id": 15230, "brand_name": "Worcester", "model_name": "Greenstar Camray Utility", "model_qualifier": "18/25", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 80.6, "comparative_hot_water_efficiency_pct": 58.9, "output_kw_max": 25.0, "final_year_of_manufacture": 2015, "raw": ["015230", "000035", "0", "2020/Sep/08 09:30", "Worcester Bosch Group", "Worcester", "Greenstar Camray Utility", "18/25", "", "2007", "2015", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "18", "25", "", "", "88.4", "80.6", "", "58.9", "", "2", "", "", "201", "1", "1", "160", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.5", "95.9", "", "", "", "", "94.8"]} -{"pcdb_id": 15231, "brand_name": "Worcester", "model_name": "Greenstar Camray Utility", "model_qualifier": "25/32", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 81.1, "comparative_hot_water_efficiency_pct": 59.3, "output_kw_max": 30.0, "final_year_of_manufacture": 2015, "raw": ["015231", "000035", "0", "2020/Sep/08 09:30", "Worcester Bosch Group", "Worcester", "Greenstar Camray Utility", "25/32", "", "2007", "2015", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "25", "30", "", "", "88.9", "81.1", "", "59.3", "", "2", "", "", "201", "1", "1", "160", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.5", "96.9", "", "", "", "", "95.9"]} -{"pcdb_id": 15232, "brand_name": "Worcester", "model_name": "Greenstar Camray External", "model_qualifier": "12/18", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 58.7, "output_kw_max": 18.0, "final_year_of_manufacture": 2015, "raw": ["015232", "000035", "0", "2020/Sep/08 09:34", "Worcester Bosch Group", "Worcester", "Greenstar Camray External", "12/18", "", "2007", "2015", "4", "1", "2", "1", "0", "", "", "2", "2", "2", "12", "18", "", "", "88.1", "80.3", "", "58.7", "", "2", "", "", "201", "1", "1", "150", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.4", "94.8", "", "", "", "", "94.2"]} -{"pcdb_id": 15233, "brand_name": "Worcester", "model_name": "Greenstar Camray External", "model_qualifier": "18/25", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 80.6, "comparative_hot_water_efficiency_pct": 58.9, "output_kw_max": 25.0, "final_year_of_manufacture": 2015, "raw": ["015233", "000035", "0", "2020/Sep/08 09:34", "Worcester Bosch Group", "Worcester", "Greenstar Camray External", "18/25", "", "2007", "2015", "4", "1", "2", "1", "0", "", "", "2", "2", "2", "18", "25", "", "", "88.4", "80.6", "", "58.9", "", "2", "", "", "201", "1", "2", "160", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.5", "95.9", "", "", "", "", "94.8"]} -{"pcdb_id": 15234, "brand_name": "Worcester", "model_name": "Greenstar Camray External", "model_qualifier": "25/32", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 81.1, "comparative_hot_water_efficiency_pct": 59.3, "output_kw_max": 30.0, "final_year_of_manufacture": 2015, "raw": ["015234", "000035", "0", "2020/Sep/08 09:50", "Worcester Bosch Group", "Worcester", "Greenstar Camray External", "25/32", "", "2007", "2015", "4", "1", "2", "1", "0", "", "", "2", "2", "2", "25", "30", "", "", "88.9", "81.1", "", "59.3", "", "2", "", "", "201", "1", "1", "160", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.5", "96.9", "", "", "", "", "95.9"]} -{"pcdb_id": 15235, "brand_name": "Worcester", "model_name": "Greenstar Heatslave External", "model_qualifier": "12/18", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 82.1, "comparative_hot_water_efficiency_pct": 41.6, "output_kw_max": 18.0, "final_year_of_manufacture": 2013, "raw": ["015235", "000035", "0", "2024/Jan/31 10:17", "Worcester Bosch Group", "Worcester", "Greenstar Heatslave External", "12/18", "", "2007", "2013", "4", "1", "2", "2", "0", "", "", "2", "2", "2", "12", "18", "", "", "88.2", "82.1", "", "41.6", "", "2", "", "", "203", "1", "1", "240", "0", "1", "1", "0", "69", "0", "25", "3", "82", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.6", "95.3", "", "", "", "", "94.4"]} -{"pcdb_id": 15236, "brand_name": "Worcester", "model_name": "Greenstar Heatslave External", "model_qualifier": "18/25", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 81.9, "comparative_hot_water_efficiency_pct": 41.6, "output_kw_max": 25.0, "final_year_of_manufacture": 2013, "raw": ["015236", "000035", "0", "2024/Jan/31 10:17", "Worcester Bosch Group", "Worcester", "Greenstar Heatslave External", "18/25", "", "2007", "2013", "4", "1", "2", "2", "0", "", "", "2", "2", "2", "18", "25", "", "", "88.0", "81.9", "", "41.6", "", "2", "", "", "203", "1", "1", "240", "0", "1", "1", "0", "69", "0", "25", "3", "82", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.0", "94.7", "", "", "", "", "94.0"]} -{"pcdb_id": 15237, "brand_name": "Worcester", "model_name": "Greenstar Heatslave External", "model_qualifier": "25/32", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 81.9, "comparative_hot_water_efficiency_pct": 41.6, "output_kw_max": 32.0, "final_year_of_manufacture": 2013, "raw": ["015237", "000035", "0", "2024/Jan/31 10:17", "Worcester Bosch Group", "Worcester", "Greenstar Heatslave External", "25/32", "", "2007", "2013", "4", "1", "2", "2", "0", "", "", "2", "2", "2", "25", "32", "", "", "88.0", "81.9", "", "41.6", "", "2", "", "", "203", "1", "1", "263", "0", "1", "1", "0", "69", "0", "25", "3", "82", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.8", "94.4", "", "", "", "", "93.9"]} -{"pcdb_id": 15238, "brand_name": "Potterton", "model_name": "Promax SL", "model_qualifier": "30", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 30.18, "final_year_of_manufacture": null, "raw": ["015238", "000005", "0", "2012/Mar/27 10:12", "Baxi Heating", "Potterton", "Promax SL", "30", "GC No. 41-591-89", "2007", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "30.18", "30.18", "", "", "88.1", "79.1", "", "57.8", "", "2", "", "", "102", "1", "2", "80", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.4", "96.4", "", "", "", "", "95.1"]} -{"pcdb_id": 15239, "brand_name": "Potterton", "model_name": "Promax SL", "model_qualifier": "24", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 22.0, "final_year_of_manufacture": null, "raw": ["015239", "000005", "0", "2012/Mar/27 10:12", "Baxi Heating", "Potterton", "Promax SL", "24", "GC No. 41-591-88", "2007", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "22.00", "22.00", "", "", "88.1", "79.1", "", "57.8", "", "2", "", "", "102", "1", "2", "80", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.5", "96.5", "", "", "", "", "95.2"]} -{"pcdb_id": 15240, "brand_name": "Potterton", "model_name": "Promax SL", "model_qualifier": "18", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 17.81, "final_year_of_manufacture": null, "raw": ["015240", "000005", "0", "2012/Mar/27 10:12", "Baxi Heating", "Potterton", "Promax SL", "18", "GC No. 41-591-80", "2007", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "17.81", "17.81", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "80", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "96.8", "", "", "", "", "95.2"]} -{"pcdb_id": 15241, "brand_name": "Potterton", "model_name": "Promax SL", "model_qualifier": "15", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 15.24, "final_year_of_manufacture": null, "raw": ["015241", "000005", "0", "2012/Mar/27 10:12", "Baxi Heating", "Potterton", "Promax SL", "15", "GC No. 41-591-87", "2007", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "15.24", "15.24", "", "", "88.3", "79.3", "", "57.9", "", "2", "", "", "102", "1", "2", "80", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.3", "96.5", "", "", "", "", "95.3"]} -{"pcdb_id": 15242, "brand_name": "Potterton", "model_name": "Promax SL", "model_qualifier": "12", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 11.82, "final_year_of_manufacture": null, "raw": ["015242", "000005", "0", "2012/Mar/27 10:12", "Baxi Heating", "Potterton", "Promax SL", "12", "GC No. 41-591-79", "2007", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "11.82", "11.82", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "80", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.6", "96.5", "", "", "", "", "95.0"]} -{"pcdb_id": 15243, "brand_name": "Main", "model_name": "System", "model_qualifier": "18 HE", "winter_efficiency_pct": 86.0, "summer_efficiency_pct": 77.0, "comparative_hot_water_efficiency_pct": 56.2, "output_kw_max": 18.0, "final_year_of_manufacture": 2011, "raw": ["015243", "000005", "0", "2013/May/07 10:32", "Baxi Heating", "Main", "System", "18 HE", "GC No. 41-467-04", "2006", "2011", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18.0", "18.0", "", "", "86.0", "77.0", "", "56.2", "", "2", "", "", "102", "1", "2", "140", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "86.6", "92.3", "", "", "", "", "91.2"]} -{"pcdb_id": 15244, "brand_name": "Main", "model_name": "System", "model_qualifier": "24 HE", "winter_efficiency_pct": 85.8, "summer_efficiency_pct": 76.8, "comparative_hot_water_efficiency_pct": 56.1, "output_kw_max": 24.0, "final_year_of_manufacture": 2011, "raw": ["015244", "000005", "0", "2013/May/07 10:33", "Baxi Heating", "Main", "System", "24 HE", "GC No. 41-467-02", "2006", "2011", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24.0", "24.0", "", "", "85.8", "76.8", "", "56.1", "", "2", "", "", "102", "1", "2", "170", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.2", "91.5", "", "", "", "", "90.7"]} -{"pcdb_id": 15245, "brand_name": "Main", "model_name": "System", "model_qualifier": "28 HE", "winter_efficiency_pct": 85.7, "summer_efficiency_pct": 76.7, "comparative_hot_water_efficiency_pct": 56.0, "output_kw_max": 28.0, "final_year_of_manufacture": 2011, "raw": ["015245", "000005", "0", "2013/May/07 10:33", "Baxi Heating", "Main", "System", "28 HE", "GC No. 41-467-03", "2006", "2011", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "28.0", "28.0", "", "", "85.7", "76.7", "", "56.0", "", "2", "", "", "102", "1", "2", "180", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.4", "91.3", "", "", "", "", "90.5"]} -{"pcdb_id": 15247, "brand_name": "Pro", "model_name": "Pro-Combi", "model_qualifier": "85HE", "winter_efficiency_pct": 85.4, "summer_efficiency_pct": 76.8, "comparative_hot_water_efficiency_pct": 54.0, "output_kw_max": 24.35, "final_year_of_manufacture": null, "raw": ["015247", "000247", "0", "2007/Jan/30 09:11", "F & P Wholesale", "Pro", "Pro-Combi", "85HE", "4709482", "2006", "current", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "24.35", "24.35", "", "", "85.4", "76.8", "", "54.0", "", "2", "", "", "104", "1", "2", "153", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.4", "90.6", "", "", "", "", "90.0"]} -{"pcdb_id": 15250, "brand_name": "Pro", "model_name": "Pro-Combi", "model_qualifier": "100HE", "winter_efficiency_pct": 85.6, "summer_efficiency_pct": 77.0, "comparative_hot_water_efficiency_pct": 54.1, "output_kw_max": 28.3, "final_year_of_manufacture": null, "raw": ["015250", "000247", "0", "2007/Jan/30 09:11", "F & P Wholesale", "Pro", "Pro-Combi", "100HE", "4709481", "2006", "current", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "28.30", "28.30", "", "", "85.6", "77.0", "", "54.1", "", "2", "", "", "104", "1", "2", "153", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.4", "90.9", "", "", "", "", "90.2"]} -{"pcdb_id": 15253, "brand_name": "Ferroli", "model_name": "Optimax", "model_qualifier": "HE 31 S", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 30.2, "final_year_of_manufacture": 2008, "raw": ["015253", "000097", "0", "2012/Mar/27 10:12", "Ferroli SpA", "Ferroli", "Optimax", "HE 31 S", "", "2007", "2008", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "30.2", "30.2", "", "", "88.7", "79.7", "", "58.2", "", "2", "", "", "102", "1", "2", "130", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.7", "98.3", "", "", "", "", "96.5"]} -{"pcdb_id": 15260, "brand_name": "Keston", "model_name": "Qudos", "model_qualifier": "28h", "winter_efficiency_pct": 89.6, "summer_efficiency_pct": 80.6, "comparative_hot_water_efficiency_pct": 58.9, "output_kw_max": 28.4, "final_year_of_manufacture": null, "raw": ["015260", "000022", "0", "2012/Mar/27 10:12", "Keston Boilers", "Keston", "Qudos", "28h", "", "2007", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "28.4", "28.4", "", "", "89.6", "80.6", "", "58.9", "", "2", "", "", "102", "1", "2", "8.5", "84", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.7", "100.1", "", "", "", "", "98.1"]} -{"pcdb_id": 15261, "brand_name": "Keston", "model_name": "Qudos", "model_qualifier": "28hp", "winter_efficiency_pct": 89.8, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 59.0, "output_kw_max": 28.4, "final_year_of_manufacture": null, "raw": ["015261", "000022", "0", "2012/Mar/27 10:12", "Keston Boilers", "Keston", "Qudos", "28hp", "", "2007", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "28.4", "28.4", "", "", "89.8", "80.8", "", "59.0", "", "2", "1", "", "102", "1", "2", "8.5", "84", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "91.7", "100.1", "", "", "", "", "98.5"]} -{"pcdb_id": 15262, "brand_name": "Keston", "model_name": "Qudos", "model_qualifier": "28s", "winter_efficiency_pct": 89.6, "summer_efficiency_pct": 80.6, "comparative_hot_water_efficiency_pct": 58.9, "output_kw_max": 28.4, "final_year_of_manufacture": null, "raw": ["015262", "000022", "0", "2012/Mar/27 10:12", "Keston Boilers", "Keston", "Qudos", "28s", "", "2007", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "28.4", "28.4", "", "", "89.6", "80.6", "", "58.9", "", "2", "", "", "102", "1", "2", "150", "8.5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.7", "100.1", "", "", "", "", "98.1"]} -{"pcdb_id": 15263, "brand_name": "Keston", "model_name": "Qudos", "model_qualifier": "28sp", "winter_efficiency_pct": 89.8, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 59.0, "output_kw_max": 28.4, "final_year_of_manufacture": null, "raw": ["015263", "000022", "0", "2012/Mar/27 10:12", "Keston Boilers", "Keston", "Qudos", "28sp", "", "2007", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "28.4", "28.4", "", "", "89.8", "80.8", "", "59.0", "", "2", "1", "", "102", "1", "2", "150", "8.5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "91.7", "100.1", "", "", "", "", "98.5"]} -{"pcdb_id": 15264, "brand_name": "Sime", "model_name": "Format", "model_qualifier": "100 B", "winter_efficiency_pct": 83.1, "summer_efficiency_pct": 73.0, "comparative_hot_water_efficiency_pct": 51.3, "output_kw_max": 30.8, "final_year_of_manufacture": 2018, "raw": ["015264", "000213", "0", "2018/Feb/26 16:55", "Fonderie Sime S.p.A.", "Sime", "Format", "100 B", "", "2007", "2018", "2", "2", "1", "2", "0", "", "", "1", "3", "2", "30.8", "30.8", "", "", "83.1", "73.0", "", "51.3", "", "2", "1", "", "104", "1", "2", "165", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "87.1", "86.5", "", "", "", "", "86.6"]} -{"pcdb_id": 15265, "brand_name": "Sime", "model_name": "Format", "model_qualifier": "100 B", "winter_efficiency_pct": 82.5, "summer_efficiency_pct": 72.4, "comparative_hot_water_efficiency_pct": 50.9, "output_kw_max": 30.8, "final_year_of_manufacture": 2018, "raw": ["015265", "000213", "0", "2018/Feb/26 16:54", "Fonderie Sime S.p.A.", "Sime", "Format", "100 B", "", "2007", "2018", "1", "2", "1", "2", "0", "", "", "1", "3", "2", "30.8", "30.8", "", "", "82.5", "72.4", "", "50.9", "", "2", "", "", "104", "1", "2", "165", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "85.2", "84.6", "", "", "", "", "84.7"]} -{"pcdb_id": 15266, "brand_name": "Sime", "model_name": "Format", "model_qualifier": "80 B", "winter_efficiency_pct": 83.1, "summer_efficiency_pct": 73.0, "comparative_hot_water_efficiency_pct": 51.3, "output_kw_max": 23.8, "final_year_of_manufacture": 2018, "raw": ["015266", "000213", "0", "2018/Feb/26 16:56", "Fonderie Sime S.p.A.", "Sime", "Format", "80 B", "", "2007", "2018", "2", "2", "1", "2", "0", "", "", "1", "3", "2", "23.8", "23.8", "", "", "83.1", "73.0", "", "51.3", "", "2", "1", "", "104", "1", "2", "120", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "87.2", "86.9", "", "", "", "", "87.0"]} -{"pcdb_id": 15267, "brand_name": "Sime", "model_name": "Format", "model_qualifier": "80 B", "winter_efficiency_pct": 82.8, "summer_efficiency_pct": 72.7, "comparative_hot_water_efficiency_pct": 51.1, "output_kw_max": 23.8, "final_year_of_manufacture": 2018, "raw": ["015267", "000213", "0", "2018/Feb/26 16:56", "Fonderie Sime S.p.A.", "Sime", "Format", "80 B", "", "2007", "2018", "1", "2", "1", "2", "0", "", "", "1", "3", "2", "23.8", "23.8", "", "", "82.8", "72.7", "", "51.1", "", "2", "", "", "104", "1", "2", "120", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "85.3", "85.1", "", "", "", "", "85.1"]} -{"pcdb_id": 15268, "brand_name": "Alpha", "model_name": "CD 35 C", "model_qualifier": "", "winter_efficiency_pct": 89.7, "summer_efficiency_pct": 81.1, "comparative_hot_water_efficiency_pct": 57.0, "output_kw_max": 28.0, "final_year_of_manufacture": null, "raw": ["015268", "000001", "0", "2007/May/24 10:22", "Alpha Therm", "Alpha", "CD 35 C", "", "", "2007", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "28", "28", "", "", "89.7", "81.1", "", "57.0", "", "2", "1", "", "104", "1", "2", "125", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.7", "100.3", "", "", "", "", "98.5"]} -{"pcdb_id": 15269, "brand_name": "Alpha", "model_name": "CD 35 C", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 56.3, "output_kw_max": 28.0, "final_year_of_manufacture": null, "raw": ["015269", "000001", "0", "2010/Sep/29 11:39", "Alpha Therm", "Alpha", "CD 35 C", "", "", "2007", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28", "28", "", "", "88.6", "80.0", "", "56.3", "", "2", "", "", "104", "1", "2", "125", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.7", "98.1", "", "", "", "", "96.3"]} -{"pcdb_id": 15270, "brand_name": "Alpha", "model_name": "CD 28 C", "model_qualifier": "", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 56.6, "output_kw_max": 24.0, "final_year_of_manufacture": null, "raw": ["015270", "000001", "0", "2007/May/24 10:22", "Alpha Therm", "Alpha", "CD 28 C", "", "", "2007", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "89.1", "80.5", "", "56.6", "", "2", "1", "", "104", "1", "2", "125", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.3", "99.1", "", "", "", "", "97.4"]} -{"pcdb_id": 15271, "brand_name": "Alpha", "model_name": "CD 28 C", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 55.9, "output_kw_max": 24.0, "final_year_of_manufacture": null, "raw": ["015271", "000001", "0", "2010/Sep/29 11:39", "Alpha Therm", "Alpha", "CD 28 C", "", "", "2007", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "88.1", "79.5", "", "55.9", "", "2", "", "", "104", "1", "2", "125", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "96.9", "", "", "", "", "95.3"]} -{"pcdb_id": 15272, "brand_name": "Alpha", "model_name": "CD 25 C", "model_qualifier": "", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 56.8, "output_kw_max": 18.0, "final_year_of_manufacture": null, "raw": ["015272", "000001", "0", "2007/May/24 10:22", "Alpha Therm", "Alpha", "CD 25 C", "", "", "2007", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "18", "18", "", "", "89.4", "80.8", "", "56.8", "", "2", "1", "", "104", "1", "2", "125", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.2", "99.9", "", "", "", "", "98.1"]} -{"pcdb_id": 15273, "brand_name": "Alpha", "model_name": "CD 25 C", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 56.1, "output_kw_max": 18.0, "final_year_of_manufacture": null, "raw": ["015273", "000001", "0", "2010/Sep/29 11:40", "Alpha Therm", "Alpha", "CD 25 C", "", "", "2007", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "18", "18", "", "", "88.4", "79.8", "", "56.1", "", "2", "", "", "104", "1", "2", "125", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.2", "97.8", "", "", "", "", "95.9"]} -{"pcdb_id": 15274, "brand_name": "Heatline", "model_name": "Vizo 24", "model_qualifier": "", "winter_efficiency_pct": 84.9, "summer_efficiency_pct": 76.3, "comparative_hot_water_efficiency_pct": 53.6, "output_kw_max": 24.82, "final_year_of_manufacture": 2009, "raw": ["015274", "000215", "0", "2011/Aug/31 10:43", "Turk Demir Dokum Fab AS", "Heatline", "Vizo 24", "", "", "2006", "2009", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.82", "24.82", "", "", "84.9", "76.3", "", "53.6", "", "2", "", "", "104", "1", "2", "196", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.0", "89.3", "", "", "", "", "88.9"]} -{"pcdb_id": 15275, "brand_name": "Heatline", "model_name": "Vizo 28", "model_qualifier": "", "winter_efficiency_pct": 85.5, "summer_efficiency_pct": 76.9, "comparative_hot_water_efficiency_pct": 54.1, "output_kw_max": 27.47, "final_year_of_manufacture": 2011, "raw": ["015275", "000215", "0", "2011/Aug/31 10:40", "Turk Demir Dokum Fab AS", "Heatline", "Vizo 28", "", "", "2006", "2011", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "27.47", "27.47", "", "", "85.5", "76.9", "", "54.1", "", "2", "", "", "104", "1", "2", "196", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "86.9", "91.0", "", "", "", "", "90.2"]} -{"pcdb_id": 15276, "brand_name": "Heatline", "model_name": "Solaris", "model_qualifier": "24 pcs", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 24.42, "final_year_of_manufacture": 2009, "raw": ["015276", "000215", "0", "2012/Mar/27 10:12", "Turk Demir Dokum Fab AS", "Heatline", "Solaris", "24 pcs", "", "2004", "2009", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24.42", "24.42", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "140", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "96.8", "", "", "", "", "95.1"]} -{"pcdb_id": 15277, "brand_name": "ATAG", "model_name": "E32C", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 56.4, "output_kw_max": 28.2, "final_year_of_manufacture": 2014, "raw": ["015277", "000227", "0", "2018/Apr/25 14:46", "ATAG Verwarming Nederland BV", "ATAG", "E32C", "", "", "2007", "2014", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "28.2", "28.2", "", "", "88.8", "80.2", "", "56.4", "", "2", "", "", "104", "1", "2", "145", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "98.8", "", "", "", "", "96.8"]} -{"pcdb_id": 15278, "brand_name": "ATAG", "model_name": "E22S", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 19.3, "final_year_of_manufacture": 2014, "raw": ["015278", "000227", "0", "2013/Oct/23 12:57", "ATAG Verwarming Nederland BV", "ATAG", "E22S", "", "", "2007", "2014", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "19.3", "19.3", "", "", "88.8", "79.8", "", "58.3", "", "2", "", "", "102", "1", "2", "122", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "98.9", "", "", "", "", "96.8"]} -{"pcdb_id": 15279, "brand_name": "ATAG", "model_name": "E22C", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 56.4, "output_kw_max": 19.3, "final_year_of_manufacture": 2014, "raw": ["015279", "000227", "0", "2013/Oct/23 12:57", "ATAG Verwarming Nederland BV", "ATAG", "E22C", "", "", "2007", "2014", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "19.3", "19.3", "", "", "88.8", "80.2", "", "56.4", "", "2", "", "", "104", "1", "2", "122", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "98.9", "", "", "", "", "96.8"]} -{"pcdb_id": 15280, "brand_name": "ATAG", "model_name": "E32S", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 28.2, "final_year_of_manufacture": 2014, "raw": ["015280", "000227", "0", "2013/Oct/23 12:58", "ATAG Verwarming Nederland BV", "ATAG", "E32S", "", "", "2007", "2014", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "28.2", "28.2", "", "", "88.8", "79.8", "", "58.3", "", "2", "", "", "102", "1", "2", "145", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "98.8", "", "", "", "", "96.8"]} -{"pcdb_id": 15281, "brand_name": "Worcester", "model_name": "Greenstar CDi", "model_qualifier": "27 CDi", "winter_efficiency_pct": 89.8, "summer_efficiency_pct": 81.2, "comparative_hot_water_efficiency_pct": 57.1, "output_kw_max": 26.2, "final_year_of_manufacture": 2012, "raw": ["015281", "000035", "0", "2020/Sep/08 09:51", "Worcester Bosch Group", "Worcester", "Greenstar CDi", "27 CDi", "47-406-13", "2007", "2012", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "26.2", "26.2", "", "", "89.8", "81.2", "", "57.1", "", "2", "1", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0305", "", "", "", "", "", "", "", "", "90.1", "101.0", "", "", "", "", "99.0"]} -{"pcdb_id": 15282, "brand_name": "Worcester", "model_name": "Greenstar CDi", "model_qualifier": "27 CDi", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 56.4, "output_kw_max": 26.2, "final_year_of_manufacture": 2012, "raw": ["015282", "000035", "0", "2020/Sep/08 09:51", "Worcester Bosch Group", "Worcester", "Greenstar CDi", "27 CDi", "47-406-12", "2007", "2012", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "26.2", "26.2", "", "", "88.8", "80.2", "", "56.4", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0305", "", "", "", "", "", "", "", "", "88.1", "98.8", "", "", "", "", "96.8"]} -{"pcdb_id": 15283, "brand_name": "Worcester", "model_name": "Greenstar CDi", "model_qualifier": "31 CDi", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 56.4, "output_kw_max": 30.0, "final_year_of_manufacture": 2012, "raw": ["015283", "000035", "0", "2020/Sep/08 09:52", "Worcester Bosch Group", "Worcester", "Greenstar CDi", "31 CDi", "47-406-14", "2007", "2012", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "30", "30", "", "", "88.8", "80.2", "", "56.4", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0305", "", "", "", "", "", "", "", "", "88.1", "98.8", "", "", "", "", "96.8"]} -{"pcdb_id": 15284, "brand_name": "Worcester", "model_name": "Greenstar CDi", "model_qualifier": "31 CDi", "winter_efficiency_pct": 89.8, "summer_efficiency_pct": 81.2, "comparative_hot_water_efficiency_pct": 57.1, "output_kw_max": 30.0, "final_year_of_manufacture": 2012, "raw": ["015284", "000035", "0", "2020/Sep/08 09:52", "Worcester Bosch Group", "Worcester", "Greenstar CDi", "31 CDi", "47-406-15", "2007", "2012", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "30", "30", "", "", "89.8", "81.2", "", "57.1", "", "2", "1", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0305", "", "", "", "", "", "", "", "", "90.1", "101.0", "", "", "", "", "99.0"]} -{"pcdb_id": 15285, "brand_name": "Baxi", "model_name": "Platinum Combi", "model_qualifier": "40 HE", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 55.8, "output_kw_max": 32.0, "final_year_of_manufacture": 2008, "raw": ["015285", "000005", "0", "2010/Nov/19 09:04", "Baxi Heating", "Baxi", "Platinum Combi", "40 HE", "GC No. 47-075-30", "2007", "2008", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "32", "32", "", "", "87.9", "79.3", "", "55.8", "", "2", "", "", "104", "1", "2", "155", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "96.7", "", "", "", "", "95.0"]} -{"pcdb_id": 15286, "brand_name": "Baxi", "model_name": "Platinum Combi", "model_qualifier": "33 HE", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 55.8, "output_kw_max": 28.0, "final_year_of_manufacture": 2008, "raw": ["015286", "000005", "0", "2010/Nov/19 09:04", "Baxi Heating", "Baxi", "Platinum Combi", "33 HE", "GC No. 47-075-29", "2007", "2008", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28", "28", "", "", "87.9", "79.3", "", "55.8", "", "2", "", "", "104", "1", "2", "160", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "96.7", "", "", "", "", "95.0"]} -{"pcdb_id": 15287, "brand_name": "Baxi", "model_name": "Platinum Combi", "model_qualifier": "28 HE", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 55.8, "output_kw_max": 24.0, "final_year_of_manufacture": 2008, "raw": ["015287", "000005", "0", "2010/Nov/19 09:04", "Baxi Heating", "Baxi", "Platinum Combi", "28 HE", "GC No. 47-075-28", "2007", "2008", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "88.0", "79.4", "", "55.8", "", "2", "", "", "104", "1", "2", "155", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "96.9", "", "", "", "", "95.2"]} -{"pcdb_id": 15288, "brand_name": "Baxi", "model_name": "Platinum Combi", "model_qualifier": "24 HE", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 55.8, "output_kw_max": 24.0, "final_year_of_manufacture": 2008, "raw": ["015288", "000005", "0", "2013/May/07 10:33", "Baxi Heating", "Baxi", "Platinum Combi", "24 HE", "GC No. 47-075-27", "2007", "2008", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "88.0", "79.4", "", "55.8", "", "2", "", "", "104", "1", "2", "155", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "96.9", "", "", "", "", "95.2"]} -{"pcdb_id": 15289, "brand_name": "Potterton", "model_name": "Promax Combi", "model_qualifier": "24 HE Plus", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 55.8, "output_kw_max": 20.0, "final_year_of_manufacture": 2008, "raw": ["015289", "000005", "0", "2010/Nov/19 09:19", "Baxi Heating", "Potterton", "Promax Combi", "24 HE Plus", "GC No. 47-393-17", "2007", "2008", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "20", "20", "", "", "88.0", "79.4", "", "55.8", "", "2", "", "", "104", "1", "2", "155", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "96.9", "", "", "", "", "95.2"]} -{"pcdb_id": 15290, "brand_name": "Baxi", "model_name": "Duo-tec Combi", "model_qualifier": "40 HE", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 55.8, "output_kw_max": 32.0, "final_year_of_manufacture": 2008, "raw": ["015290", "000005", "0", "2010/Nov/19 09:05", "Baxi Heating", "Baxi", "Duo-tec Combi", "40 HE", "GC No. 47-075-26", "2007", "2008", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "32", "32", "", "", "87.9", "79.3", "", "55.8", "", "2", "", "", "104", "1", "2", "155", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "96.7", "", "", "", "", "95.0"]} -{"pcdb_id": 15291, "brand_name": "Baxi", "model_name": "Megaflo System", "model_qualifier": "15 HE", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 15.0, "final_year_of_manufacture": 2008, "raw": ["015291", "000005", "0", "2012/Mar/27 10:12", "Baxi Heating", "Baxi", "Megaflo System", "15 HE", "GC No. 41-075-52", "2007", "2008", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "15", "15", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "130", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "96.8", "", "", "", "", "95.1"]} -{"pcdb_id": 15292, "brand_name": "Baxi", "model_name": "Megaflo System", "model_qualifier": "18 HE", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 18.0, "final_year_of_manufacture": 2008, "raw": ["015292", "000005", "0", "2012/Mar/27 10:12", "Baxi Heating", "Baxi", "Megaflo System", "18 HE", "GC No. 41-075-53", "2007", "2008", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18", "18", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "140", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "96.9", "", "", "", "", "95.2"]} -{"pcdb_id": 15293, "brand_name": "Baxi", "model_name": "Megaflo System", "model_qualifier": "32 HE", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 78.9, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 32.0, "final_year_of_manufacture": 2008, "raw": ["015293", "000005", "0", "2012/Mar/27 10:12", "Baxi Heating", "Baxi", "Megaflo System", "32 HE", "GC No. 41-075-54", "2007", "2008", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "32", "32", "", "", "87.9", "78.9", "", "57.7", "", "2", "", "", "102", "1", "2", "160", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "96.7", "", "", "", "", "95.0"]} -{"pcdb_id": 15294, "brand_name": "E.C.A.", "model_name": "Confeo Premix", "model_qualifier": "CP 24 HCH", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 24.0, "final_year_of_manufacture": null, "raw": ["015294", "000248", "0", "2012/Mar/27 10:12", "Emas Makina Sanayi AS", "E.C.A.", "Confeo Premix", "CP 24 HCH", "", "2006", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "24", "24", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "115", "4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "96.9", "", "", "", "", "95.2"]} -{"pcdb_id": 15299, "brand_name": "E.C.A.", "model_name": "Confeo Premix", "model_qualifier": "CP 24 HM", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 86.6, "comparative_hot_water_efficiency_pct": 71.8, "output_kw_max": 22.2, "final_year_of_manufacture": null, "raw": ["015299", "000248", "0", "2012/Jun/28 15:41", "Emas Makina Sanayi AS", "E.C.A.", "Confeo Premix", "CP 24 HM", "", "2006", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "22.2", "22.2", "", "", "88.0", "86.6", "", "71.8", "", "2", "", "", "104", "1", "2", "127", "5", "0", "", "", "0", "0", "", "", "", "", "1", "7.3381", "0.2007", "0.0144", "1.127", "", "", "", "", "", "1", "1", "0", "0005", "", "", "", "", "", "", "", "", "87.8", "96.9", "", "", "", "", "95.2"]} -{"pcdb_id": 15300, "brand_name": "E.C.A.", "model_name": "Confeo Premix", "model_qualifier": "CP 24 HCH", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 24.0, "final_year_of_manufacture": null, "raw": ["015300", "000248", "0", "2012/Mar/27 10:12", "Emas Makina Sanayi AS", "E.C.A.", "Confeo Premix", "CP 24 HCH", "", "2006", "current", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "24", "24", "", "", "89.0", "80.0", "", "58.5", "", "2", "1", "", "102", "1", "2", "115", "4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.8", "99.1", "", "", "", "", "97.3"]} -{"pcdb_id": 15301, "brand_name": "E.C.A.", "model_name": "Confeo Premix", "model_qualifier": "CP 24 HM", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.4, "comparative_hot_water_efficiency_pct": 62.8, "output_kw_max": 22.2, "final_year_of_manufacture": null, "raw": ["015301", "000248", "0", "2013/Apr/08 09:34", "Emas Makina Sanayi AS", "E.C.A.", "Confeo Premix", "CP 24 HM", "", "2006", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "22.2", "22.2", "", "", "89.0", "80.4", "", "62.8", "", "2", "1", "", "104", "1", "2", "127", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "0", "0005", "", "", "", "", "", "", "", "", "89.8", "99.1", "", "", "", "", "97.3"]} -{"pcdb_id": 15302, "brand_name": "E.C.A.", "model_name": "Confeo Premix", "model_qualifier": "CP 24 HST", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 24.0, "final_year_of_manufacture": null, "raw": ["015302", "000248", "0", "2012/Mar/27 10:12", "Emas Makina Sanayi AS", "E.C.A.", "Confeo Premix", "CP 24 HST", "", "2006", "current", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "24", "24", "", "", "89.0", "80.0", "", "58.5", "", "2", "1", "", "102", "1", "2", "115", "4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.8", "99.1", "", "", "", "", "97.3"]} -{"pcdb_id": 15303, "brand_name": "E.C.A.", "model_name": "Confeo Premix", "model_qualifier": "CP 24 HST", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 24.0, "final_year_of_manufacture": null, "raw": ["015303", "000248", "0", "2012/Mar/27 10:12", "Emas Makina Sanayi AS", "E.C.A.", "Confeo Premix", "CP 24 HST", "", "2006", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "24", "24", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "115", "4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "96.9", "", "", "", "", "95.2"]} -{"pcdb_id": 15304, "brand_name": "E.C.A.", "model_name": "Confeo Premix", "model_qualifier": "CP 30 HCH", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 30.0, "final_year_of_manufacture": null, "raw": ["015304", "000248", "0", "2012/Mar/27 10:12", "Emas Makina Sanayi AS", "E.C.A.", "Confeo Premix", "CP 30 HCH", "", "2006", "current", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "30", "30", "", "", "89.2", "80.2", "", "58.6", "", "2", "1", "", "102", "1", "2", "115", "4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.9", "99.6", "", "", "", "", "97.7"]} -{"pcdb_id": 15305, "brand_name": "E.C.A.", "model_name": "Confeo Premix", "model_qualifier": "CP 30 HCH", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 30.0, "final_year_of_manufacture": null, "raw": ["015305", "000248", "0", "2012/Mar/27 10:12", "Emas Makina Sanayi AS", "E.C.A.", "Confeo Premix", "CP 30 HCH", "", "2006", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "30", "30", "", "", "88.2", "79.2", "", "57.9", "", "2", "", "", "102", "1", "2", "115", "4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "97.4", "", "", "", "", "95.6"]} -{"pcdb_id": 15306, "brand_name": "E.C.A.", "model_name": "Confeo Premix", "model_qualifier": "CP 30 HM", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 80.6, "comparative_hot_water_efficiency_pct": 62.9, "output_kw_max": 27.3, "final_year_of_manufacture": null, "raw": ["015306", "000248", "0", "2013/Apr/08 09:34", "Emas Makina Sanayi AS", "E.C.A.", "Confeo Premix", "CP 30 HM", "", "2006", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "27.3", "27.3", "", "", "89.2", "80.6", "", "62.9", "", "2", "1", "", "104", "1", "2", "134", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "0", "0005", "", "", "", "", "", "", "", "", "89.9", "99.6", "", "", "", "", "97.7"]} -{"pcdb_id": 15307, "brand_name": "E.C.A.", "model_name": "Confeo Premix", "model_qualifier": "CP 30 HM", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 86.7, "comparative_hot_water_efficiency_pct": 70.5, "output_kw_max": 27.3, "final_year_of_manufacture": null, "raw": ["015307", "000248", "0", "2012/Jun/28 15:44", "Emas Makina Sanayi AS", "E.C.A.", "Confeo Premix", "CP 30 HM", "", "2006", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "27.3", "27.3", "", "", "88.2", "86.7", "", "70.5", "", "2", "", "", "104", "1", "2", "134", "5", "0", "", "", "0", "0", "", "", "", "", "1", "7.4688", "0.225", "0.008", "1.29223", "", "", "", "", "", "1", "1", "0", "0005", "", "", "", "", "", "", "", "", "87.9", "97.4", "", "", "", "", "95.6"]} -{"pcdb_id": 15308, "brand_name": "E.C.A.", "model_name": "Confeo Premix", "model_qualifier": "CP 30 HST", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 30.0, "final_year_of_manufacture": null, "raw": ["015308", "000248", "0", "2012/Mar/27 10:12", "Emas Makina Sanayi AS", "E.C.A.", "Confeo Premix", "CP 30 HST", "", "2006", "current", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "30", "30", "", "", "89.2", "80.2", "", "58.6", "", "2", "1", "", "102", "1", "2", "115", "4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.9", "99.6", "", "", "", "", "97.7"]} -{"pcdb_id": 15309, "brand_name": "E.C.A.", "model_name": "Confeo Premix", "model_qualifier": "CP 30 HST", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 30.0, "final_year_of_manufacture": null, "raw": ["015309", "000248", "0", "2012/Mar/27 10:12", "Emas Makina Sanayi AS", "E.C.A.", "Confeo Premix", "CP 30 HST", "", "2006", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "30", "30", "", "", "88.2", "79.2", "", "57.9", "", "2", "", "", "102", "1", "2", "115", "4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "97.4", "", "", "", "", "95.6"]} -{"pcdb_id": 15310, "brand_name": "Mistral", "model_name": "CC 15/26 Plus Contract", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 81.9, "comparative_hot_water_efficiency_pct": 50.3, "output_kw_max": 26.4, "final_year_of_manufacture": null, "raw": ["015310", "000056", "0", "2024/Jan/31 10:17", "Mistral Boilers", "Mistral", "CC 15/26 Plus Contract", "", "", "2007", "current", "4", "1", "1", "2", "0", "", "", "2", "3", "2", "15", "26.4", "", "", "88.0", "81.9", "", "50.3", "", "2", "", "", "203", "1", "1", "230", "0", "2", "1", "0", "35", "0", "25", "3", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.8", "94.8", "", "", "", "", "94.1"]} -{"pcdb_id": 15312, "brand_name": "Mistral", "model_name": "CC1 15/20 Std", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 81.9, "comparative_hot_water_efficiency_pct": 50.3, "output_kw_max": 20.5, "final_year_of_manufacture": null, "raw": ["015312", "000056", "0", "2024/Jan/31 10:17", "Mistral Boilers", "Mistral", "CC1 15/20 Std", "", "", "2007", "current", "4", "1", "1", "2", "0", "", "", "2", "3", "2", "15", "20.5", "", "", "88.0", "81.9", "", "50.3", "", "2", "", "", "203", "1", "1", "230", "0", "2", "", "0", "35", "0", "25", "3", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.8", "94.8", "", "", "", "", "94.1"]} -{"pcdb_id": 15313, "brand_name": "Mistral", "model_name": "CC2 20/26 Std", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 81.9, "comparative_hot_water_efficiency_pct": 50.3, "output_kw_max": 26.4, "final_year_of_manufacture": null, "raw": ["015313", "000056", "0", "2024/Jan/31 10:17", "Mistral Boilers", "Mistral", "CC2 20/26 Std", "", "", "2007", "current", "4", "1", "1", "2", "0", "", "", "2", "3", "2", "20.5", "26.4", "", "", "88.0", "81.9", "", "50.3", "", "2", "", "", "203", "1", "1", "230", "0", "2", "", "0", "35", "0", "25", "3", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.8", "94.8", "", "", "", "", "94.1"]} -{"pcdb_id": 15314, "brand_name": "Mistral", "model_name": "CC 15/26 Std Contract", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 81.9, "comparative_hot_water_efficiency_pct": 50.3, "output_kw_max": 26.4, "final_year_of_manufacture": null, "raw": ["015314", "000056", "0", "2024/Jan/31 10:17", "Mistral Boilers", "Mistral", "CC 15/26 Std Contract", "", "", "2007", "current", "4", "1", "1", "2", "0", "", "", "2", "3", "2", "15", "26.4", "", "", "88.0", "81.9", "", "50.3", "", "2", "", "", "203", "1", "1", "230", "0", "2", "", "0", "35", "0", "25", "3", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.8", "94.8", "", "", "", "", "94.1"]} -{"pcdb_id": 15315, "brand_name": "Mistral", "model_name": "CBH1 15/20", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 20.5, "final_year_of_manufacture": null, "raw": ["015315", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "CBH1 15/20", "", "", "2007", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "15", "20.5", "", "", "88.0", "80.2", "", "58.6", "", "2", "", "", "201", "1", "1", "230", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.8", "94.8", "", "", "", "", "94.1"]} -{"pcdb_id": 15317, "brand_name": "Mistral", "model_name": "CBH2 20/26", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 26.4, "final_year_of_manufacture": null, "raw": ["015317", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "CBH2 20/26", "", "", "2007", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "20.5", "26.4", "", "", "88.0", "80.2", "", "58.6", "", "2", "", "", "201", "1", "1", "230", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.8", "94.8", "", "", "", "", "94.1"]} -{"pcdb_id": 15318, "brand_name": "Mistral", "model_name": "CBH 15/26 Contract", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 26.4, "final_year_of_manufacture": null, "raw": ["015318", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "CBH 15/26 Contract", "", "", "2007", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "15", "26.4", "", "", "88.0", "80.2", "", "58.6", "", "2", "", "", "201", "1", "1", "230", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.8", "94.8", "", "", "", "", "94.1"]} -{"pcdb_id": 15319, "brand_name": "Mistral", "model_name": "CC1 15/20 Plus", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 81.9, "comparative_hot_water_efficiency_pct": 50.3, "output_kw_max": 20.5, "final_year_of_manufacture": null, "raw": ["015319", "000056", "0", "2024/Jan/31 10:17", "Mistral Boilers", "Mistral", "CC1 15/20 Plus", "", "", "2007", "current", "4", "1", "1", "2", "0", "", "", "2", "3", "2", "15", "20.5", "", "", "88.0", "81.9", "", "50.3", "", "2", "", "", "203", "1", "1", "230", "0", "2", "", "0", "35", "0", "25", "3", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.8", "94.8", "", "", "", "", "94.1"]} -{"pcdb_id": 15320, "brand_name": "Mistral", "model_name": "CC2 20/26 Plus", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 81.9, "comparative_hot_water_efficiency_pct": 50.3, "output_kw_max": 26.4, "final_year_of_manufacture": null, "raw": ["015320", "000056", "0", "2024/Jan/31 10:17", "Mistral Boilers", "Mistral", "CC2 20/26 Plus", "", "", "2007", "current", "4", "1", "1", "2", "0", "", "", "2", "3", "2", "20.5", "26.4", "", "", "88.0", "81.9", "", "50.3", "", "2", "", "", "203", "1", "1", "230", "0", "2", "", "0", "35", "0", "25", "3", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.8", "94.8", "", "", "", "", "94.1"]} -{"pcdb_id": 15321, "brand_name": "Mistral", "model_name": "CKUT 15/26 Contract", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 26.4, "final_year_of_manufacture": null, "raw": ["015321", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "CKUT 15/26 Contract", "", "", "2007", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "15", "26.4", "", "", "88.0", "80.2", "", "58.6", "", "2", "", "", "201", "1", "1", "230", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.8", "94.8", "", "", "", "", "94.1"]} -{"pcdb_id": 15322, "brand_name": "Mistral", "model_name": "CKUT2 20/26", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 26.4, "final_year_of_manufacture": null, "raw": ["015322", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "CKUT2 20/26", "", "", "2007", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "20.5", "26.4", "", "", "88.0", "80.2", "", "58.6", "", "2", "", "", "201", "1", "1", "230", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.8", "94.8", "", "", "", "", "94.1"]} -{"pcdb_id": 15323, "brand_name": "Mistral", "model_name": "CKUT1 15/20", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 20.5, "final_year_of_manufacture": null, "raw": ["015323", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "CKUT1 15/20", "", "", "2007", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "15", "20.5", "", "", "88.0", "80.2", "", "58.6", "", "2", "", "", "201", "1", "1", "230", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.8", "94.8", "", "", "", "", "94.1"]} -{"pcdb_id": 15324, "brand_name": "Mistral", "model_name": "COD 15/26 Contract", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 26.4, "final_year_of_manufacture": null, "raw": ["015324", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "COD 15/26 Contract", "", "", "2007", "current", "4", "1", "2", "1", "0", "", "", "2", "3", "2", "15", "26.4", "", "", "88.0", "80.2", "", "58.6", "", "2", "", "", "201", "1", "1", "230", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.8", "94.8", "", "", "", "", "94.1"]} -{"pcdb_id": 15325, "brand_name": "Mistral", "model_name": "COD2 20/26", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 26.4, "final_year_of_manufacture": null, "raw": ["015325", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "COD2 20/26", "", "", "2007", "current", "4", "1", "2", "1", "0", "", "", "2", "3", "2", "20.5", "26.4", "", "", "88.0", "80.2", "", "58.6", "", "2", "", "", "201", "1", "1", "230", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.8", "94.8", "", "", "", "", "94.1"]} -{"pcdb_id": 15326, "brand_name": "Mistral", "model_name": "COD1 15/20", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 20.5, "final_year_of_manufacture": null, "raw": ["015326", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "COD1 15/20", "", "", "2007", "current", "4", "1", "2", "1", "0", "", "", "2", "3", "2", "15", "20.5", "", "", "88.0", "80.2", "", "58.6", "", "2", "", "", "201", "1", "1", "230", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.8", "94.8", "", "", "", "", "94.1"]} -{"pcdb_id": 15327, "brand_name": "Mistral", "model_name": "COD1 SS 15/20", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 20.5, "final_year_of_manufacture": null, "raw": ["015327", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "COD1 SS 15/20", "", "", "2007", "current", "4", "1", "2", "1", "0", "", "", "2", "3", "2", "15", "20.5", "", "", "88.0", "80.2", "", "58.6", "", "2", "", "", "201", "1", "1", "230", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.8", "94.8", "", "", "", "", "94.1"]} -{"pcdb_id": 15328, "brand_name": "Mistral", "model_name": "COD2 SS 20/26", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 26.4, "final_year_of_manufacture": null, "raw": ["015328", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "COD2 SS 20/26", "", "", "2007", "current", "4", "1", "2", "1", "0", "", "", "2", "3", "2", "20.5", "26.4", "", "", "88.0", "80.2", "", "58.6", "", "2", "", "", "201", "1", "1", "230", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.8", "94.8", "", "", "", "", "94.1"]} -{"pcdb_id": 15329, "brand_name": "Mistral", "model_name": "COD SS 15/26 Contract", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 26.4, "final_year_of_manufacture": null, "raw": ["015329", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "COD SS 15/26 Contract", "", "", "2007", "current", "4", "1", "2", "1", "0", "", "", "2", "3", "2", "15.0", "26.4", "", "", "88.0", "80.2", "", "58.6", "", "2", "", "", "201", "1", "1", "230", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.8", "94.8", "", "", "", "", "94.1"]} -{"pcdb_id": 15330, "brand_name": "Mistral", "model_name": "CODC 15/26 Std Contract", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 81.9, "comparative_hot_water_efficiency_pct": 50.3, "output_kw_max": 26.4, "final_year_of_manufacture": null, "raw": ["015330", "000056", "0", "2024/Jan/31 10:17", "Mistral Boilers", "Mistral", "CODC 15/26 Std Contract", "", "", "2007", "current", "4", "1", "2", "2", "0", "", "", "2", "3", "2", "15.0", "26.4", "", "", "88.0", "81.9", "", "50.3", "", "2", "", "", "203", "1", "1", "230", "0", "2", "", "0", "35", "0", "25", "3", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.8", "94.8", "", "", "", "", "94.1"]} -{"pcdb_id": 15332, "brand_name": "Mistral", "model_name": "CODC2 20/26 Std", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 81.9, "comparative_hot_water_efficiency_pct": 50.3, "output_kw_max": 26.4, "final_year_of_manufacture": null, "raw": ["015332", "000056", "0", "2024/Jan/31 10:17", "Mistral Boilers", "Mistral", "CODC2 20/26 Std", "", "", "2007", "current", "4", "1", "2", "2", "0", "", "", "2", "3", "2", "20.0", "26.4", "", "", "88.0", "81.9", "", "50.3", "", "2", "", "", "203", "1", "1", "230", "0", "2", "", "0", "35", "0", "25", "3", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.8", "94.8", "", "", "", "", "94.1"]} -{"pcdb_id": 15333, "brand_name": "Mistral", "model_name": "CODC 15/26 Plus Contract", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 81.9, "comparative_hot_water_efficiency_pct": 50.3, "output_kw_max": 26.4, "final_year_of_manufacture": null, "raw": ["015333", "000056", "0", "2024/Jan/31 10:17", "Mistral Boilers", "Mistral", "CODC 15/26 Plus Contract", "", "", "2007", "current", "4", "1", "2", "2", "0", "", "", "2", "3", "2", "15.0", "26.4", "", "", "88.0", "81.9", "", "50.3", "", "2", "", "", "203", "1", "1", "230", "0", "2", "", "0", "35", "0", "25", "3", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.8", "94.8", "", "", "", "", "94.1"]} -{"pcdb_id": 15334, "brand_name": "Mistral", "model_name": "CODC2 20/26 Plus", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 81.9, "comparative_hot_water_efficiency_pct": 50.3, "output_kw_max": 26.4, "final_year_of_manufacture": null, "raw": ["015334", "000056", "0", "2024/Jan/31 10:17", "Mistral Boilers", "Mistral", "CODC2 20/26 Plus", "", "", "2007", "current", "4", "1", "2", "2", "0", "", "", "2", "3", "2", "20.0", "26.4", "", "", "88.0", "81.9", "", "50.3", "", "2", "", "", "203", "1", "1", "230", "0", "2", "", "0", "35", "0", "25", "3", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.8", "94.8", "", "", "", "", "94.1"]} -{"pcdb_id": 15335, "brand_name": "Mistral", "model_name": "CODC1 15/20 Plus", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 81.9, "comparative_hot_water_efficiency_pct": 50.3, "output_kw_max": 20.5, "final_year_of_manufacture": null, "raw": ["015335", "000056", "0", "2024/Jan/31 10:17", "Mistral Boilers", "Mistral", "CODC1 15/20 Plus", "", "", "2007", "current", "4", "1", "2", "2", "0", "", "", "2", "3", "2", "15.0", "20.5", "", "", "88.0", "81.9", "", "50.3", "", "2", "", "", "203", "1", "1", "230", "0", "2", "", "0", "35", "0", "25", "3", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.8", "94.8", "", "", "", "", "94.1"]} -{"pcdb_id": 15336, "brand_name": "Mistral", "model_name": "CS 15/26 Contract", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 26.4, "final_year_of_manufacture": null, "raw": ["015336", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "CS 15/26 Contract", "", "", "2007", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "15.0", "26.4", "", "", "88.0", "80.2", "", "58.6", "", "2", "", "", "201", "1", "1", "230", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.8", "94.8", "", "", "", "", "94.1"]} -{"pcdb_id": 15337, "brand_name": "Mistral", "model_name": "CS1 15/20", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 20.5, "final_year_of_manufacture": null, "raw": ["015337", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "CS1 15/20", "", "", "2007", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "15.0", "20.5", "", "", "88.0", "80.2", "", "58.6", "", "2", "", "", "201", "1", "1", "230", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.8", "94.8", "", "", "", "", "94.1"]} -{"pcdb_id": 15338, "brand_name": "Mistral", "model_name": "CS2 20/26", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 26.4, "final_year_of_manufacture": null, "raw": ["015338", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "CS2 20/26", "", "", "2007", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "20.5", "26.4", "", "", "88.0", "80.2", "", "58.6", "", "2", "", "", "201", "1", "1", "230", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.8", "94.8", "", "", "", "", "94.1"]} -{"pcdb_id": 15339, "brand_name": "Mistral", "model_name": "CBH 26/40 Contract", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 58.7, "output_kw_max": 40.0, "final_year_of_manufacture": null, "raw": ["015339", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "CBH 26/40 Contract", "", "", "2007", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "26.4", "40", "", "", "88.1", "80.3", "", "58.7", "", "2", "", "", "201", "1", "1", "230", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.7", "95.2", "", "", "", "", "94.3"]} -{"pcdb_id": 15340, "brand_name": "Mistral", "model_name": "CBH4 35/40", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 58.7, "output_kw_max": 40.0, "final_year_of_manufacture": null, "raw": ["015340", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "CBH4 35/40", "", "", "2007", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "35", "40", "", "", "88.1", "80.3", "", "58.7", "", "2", "", "", "201", "1", "1", "230", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.7", "95.2", "", "", "", "", "94.3"]} -{"pcdb_id": 15341, "brand_name": "Mistral", "model_name": "CBH3 26/35", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 58.7, "output_kw_max": 35.0, "final_year_of_manufacture": null, "raw": ["015341", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "CBH3 26/35", "", "", "2007", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "26", "35", "", "", "88.1", "80.3", "", "58.7", "", "2", "", "", "201", "1", "1", "230", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.7", "95.2", "", "", "", "", "94.3"]} -{"pcdb_id": 15342, "brand_name": "Mistral", "model_name": "CODC3 26/35 Std", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 82.0, "comparative_hot_water_efficiency_pct": 50.4, "output_kw_max": 35.0, "final_year_of_manufacture": null, "raw": ["015342", "000056", "0", "2024/Jan/31 10:17", "Mistral Boilers", "Mistral", "CODC3 26/35 Std", "", "", "2007", "current", "4", "1", "2", "2", "0", "", "", "2", "3", "2", "26", "35", "", "", "88.1", "82.0", "", "50.4", "", "2", "", "", "203", "1", "1", "230", "0", "2", "", "0", "35", "0", "25", "3", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.7", "95.2", "", "", "", "", "94.3"]} -{"pcdb_id": 15343, "brand_name": "Mistral", "model_name": "CODC4 35/40 Std", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 82.0, "comparative_hot_water_efficiency_pct": 50.4, "output_kw_max": 40.0, "final_year_of_manufacture": null, "raw": ["015343", "000056", "0", "2024/Jan/31 10:17", "Mistral Boilers", "Mistral", "CODC4 35/40 Std", "", "", "2007", "current", "4", "1", "2", "2", "0", "", "", "2", "3", "2", "35", "40", "", "", "88.1", "82.0", "", "50.4", "", "2", "", "", "203", "1", "1", "230", "0", "2", "", "0", "35", "0", "25", "3", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.7", "95.2", "", "", "", "", "94.3"]} -{"pcdb_id": 15344, "brand_name": "Mistral", "model_name": "CODC 26/40 Std Contract", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 82.0, "comparative_hot_water_efficiency_pct": 50.4, "output_kw_max": 40.0, "final_year_of_manufacture": null, "raw": ["015344", "000056", "0", "2024/Jan/31 10:17", "Mistral Boilers", "Mistral", "CODC 26/40 Std Contract", "", "", "2007", "current", "4", "1", "2", "2", "0", "", "", "2", "3", "2", "26.4", "40", "", "", "88.1", "82.0", "", "50.4", "", "2", "", "", "203", "1", "1", "230", "0", "2", "", "0", "35", "0", "25", "3", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.7", "95.2", "", "", "", "", "94.3"]} -{"pcdb_id": 15345, "brand_name": "Mistral", "model_name": "CC 26/40 Std Contract", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 82.0, "comparative_hot_water_efficiency_pct": 50.4, "output_kw_max": 40.0, "final_year_of_manufacture": null, "raw": ["015345", "000056", "0", "2024/Jan/31 10:17", "Mistral Boilers", "Mistral", "CC 26/40 Std Contract", "", "", "2007", "current", "4", "1", "1", "2", "0", "", "", "2", "3", "2", "26", "40", "", "", "88.1", "82.0", "", "50.4", "", "2", "", "", "203", "1", "1", "230", "0", "2", "", "0", "35", "0", "25", "3", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.7", "95.2", "", "", "", "", "94.3"]} -{"pcdb_id": 15346, "brand_name": "Mistral", "model_name": "CC4 35/40 Std", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 82.0, "comparative_hot_water_efficiency_pct": 50.4, "output_kw_max": 40.0, "final_year_of_manufacture": null, "raw": ["015346", "000056", "0", "2024/Jan/31 10:17", "Mistral Boilers", "Mistral", "CC4 35/40 Std", "", "", "2007", "current", "4", "1", "1", "2", "0", "", "", "2", "3", "2", "35", "40", "", "", "88.1", "82.0", "", "50.4", "", "2", "", "", "203", "1", "1", "230", "0", "2", "", "0", "35", "0", "25", "3", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.7", "95.2", "", "", "", "", "94.3"]} -{"pcdb_id": 15347, "brand_name": "Mistral", "model_name": "CC3 26/35 Std", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 82.0, "comparative_hot_water_efficiency_pct": 50.4, "output_kw_max": 35.0, "final_year_of_manufacture": null, "raw": ["015347", "000056", "0", "2024/Jan/31 10:17", "Mistral Boilers", "Mistral", "CC3 26/35 Std", "", "", "2007", "current", "4", "1", "1", "2", "0", "", "", "2", "3", "2", "26", "35", "", "", "88.1", "82.0", "", "50.4", "", "2", "", "", "203", "1", "1", "230", "0", "2", "", "0", "35", "0", "25", "3", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.7", "95.2", "", "", "", "", "94.3"]} -{"pcdb_id": 15348, "brand_name": "Mistral", "model_name": "CKUT 26/40 Contract", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 58.7, "output_kw_max": 40.0, "final_year_of_manufacture": null, "raw": ["015348", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "CKUT 26/40 Contract", "", "", "2007", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "26", "40", "", "", "88.1", "80.3", "", "58.7", "", "2", "", "", "201", "1", "1", "230", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.7", "95.2", "", "", "", "", "94.3"]} -{"pcdb_id": 15349, "brand_name": "Mistral", "model_name": "CKUT3 26/35", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 58.7, "output_kw_max": 35.0, "final_year_of_manufacture": null, "raw": ["015349", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "CKUT3 26/35", "", "", "2007", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "26", "35", "", "", "88.1", "80.3", "", "58.7", "", "2", "", "", "201", "1", "1", "230", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.7", "95.2", "", "", "", "", "94.3"]} -{"pcdb_id": 15350, "brand_name": "Mistral", "model_name": "CKUT4 35/40", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 58.7, "output_kw_max": 40.0, "final_year_of_manufacture": null, "raw": ["015350", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "CKUT4 35/40", "", "", "2007", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "35", "40", "", "", "88.1", "80.3", "", "58.7", "", "2", "", "", "201", "1", "1", "230", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.7", "95.2", "", "", "", "", "94.3"]} -{"pcdb_id": 15351, "brand_name": "Mistral", "model_name": "COD3 26/35", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 58.7, "output_kw_max": 35.0, "final_year_of_manufacture": null, "raw": ["015351", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "COD3 26/35", "", "", "2007", "current", "4", "1", "2", "1", "0", "", "", "2", "3", "2", "26", "35", "", "", "88.1", "80.3", "", "58.7", "", "2", "", "", "201", "1", "1", "230", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.7", "95.2", "", "", "", "", "94.3"]} -{"pcdb_id": 15352, "brand_name": "Mistral", "model_name": "COD 26/40 Contract", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 58.7, "output_kw_max": 40.0, "final_year_of_manufacture": null, "raw": ["015352", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "COD 26/40 Contract", "", "", "2007", "current", "4", "1", "2", "1", "0", "", "", "2", "3", "2", "26", "40", "", "", "88.1", "80.3", "", "58.7", "", "2", "", "", "201", "1", "1", "230", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.7", "95.2", "", "", "", "", "94.3"]} -{"pcdb_id": 15353, "brand_name": "Mistral", "model_name": "COD4 35/40", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 58.7, "output_kw_max": 40.0, "final_year_of_manufacture": null, "raw": ["015353", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "COD4 35/40", "", "", "2007", "current", "4", "1", "2", "1", "0", "", "", "2", "3", "2", "35", "40", "", "", "88.1", "80.3", "", "58.7", "", "2", "", "", "201", "1", "1", "230", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.7", "95.2", "", "", "", "", "94.3"]} -{"pcdb_id": 15354, "brand_name": "Mistral", "model_name": "CODC3 26/35 plus", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 82.0, "comparative_hot_water_efficiency_pct": 50.4, "output_kw_max": 40.0, "final_year_of_manufacture": null, "raw": ["015354", "000056", "0", "2024/Jan/31 10:17", "Mistral Boilers", "Mistral", "CODC3 26/35 plus", "", "", "2007", "current", "4", "1", "2", "2", "0", "", "", "2", "3", "2", "35", "40", "", "", "88.1", "82.0", "", "50.4", "", "2", "", "", "203", "1", "1", "230", "0", "2", "", "0", "35", "0", "25", "3", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.7", "95.2", "", "", "", "", "94.3"]} -{"pcdb_id": 15355, "brand_name": "Mistral", "model_name": "CODC 26/40 plus contract", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 82.0, "comparative_hot_water_efficiency_pct": 50.4, "output_kw_max": 40.0, "final_year_of_manufacture": null, "raw": ["015355", "000056", "0", "2024/Jan/31 10:17", "Mistral Boilers", "Mistral", "CODC 26/40 plus contract", "", "", "2007", "current", "4", "1", "2", "2", "0", "", "", "2", "3", "2", "26", "40", "", "", "88.1", "82.0", "", "50.4", "", "2", "", "", "203", "1", "1", "230", "0", "2", "", "0", "35", "0", "25", "3", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.7", "95.2", "", "", "", "", "94.3"]} -{"pcdb_id": 15356, "brand_name": "Mistral", "model_name": "CODC4 35/40 plus", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 82.0, "comparative_hot_water_efficiency_pct": 50.4, "output_kw_max": 40.0, "final_year_of_manufacture": null, "raw": ["015356", "000056", "0", "2024/Jan/31 10:17", "Mistral Boilers", "Mistral", "CODC4 35/40 plus", "", "", "2007", "current", "4", "1", "2", "2", "0", "", "", "2", "3", "2", "35", "40", "", "", "88.1", "82.0", "", "50.4", "", "2", "", "", "203", "1", "1", "230", "0", "2", "", "0", "35", "0", "25", "3", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.7", "95.2", "", "", "", "", "94.3"]} -{"pcdb_id": 15357, "brand_name": "Mistral", "model_name": "CC 26/40 plus contract", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 82.0, "comparative_hot_water_efficiency_pct": 50.2, "output_kw_max": 40.0, "final_year_of_manufacture": null, "raw": ["015357", "000056", "0", "2024/Jan/31 10:17", "Mistral Boilers", "Mistral", "CC 26/40 plus contract", "", "", "2007", "current", "4", "1", "2", "2", "0", "", "", "2", "3", "2", "35", "40", "", "", "88.1", "82.0", "", "50.2", "", "2", "", "", "203", "1", "1", "230", "0", "2", "1", "0", "40", "0", "25", "3", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.7", "95.2", "", "", "", "", "94.3"]} -{"pcdb_id": 15358, "brand_name": "Mistral", "model_name": "CC4 35/40 plus", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 82.0, "comparative_hot_water_efficiency_pct": 50.4, "output_kw_max": 40.0, "final_year_of_manufacture": null, "raw": ["015358", "000056", "0", "2024/Jan/31 10:17", "Mistral Boilers", "Mistral", "CC4 35/40 plus", "", "", "2007", "current", "4", "1", "1", "2", "0", "", "", "2", "3", "2", "35", "40", "", "", "88.1", "82.0", "", "50.4", "", "2", "", "", "203", "1", "1", "230", "0", "2", "", "0", "35", "0", "25", "3", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.7", "95.2", "", "", "", "", "94.3"]} -{"pcdb_id": 15359, "brand_name": "Mistral", "model_name": "CC3 26/35 plus", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 82.0, "comparative_hot_water_efficiency_pct": 50.4, "output_kw_max": 35.0, "final_year_of_manufacture": null, "raw": ["015359", "000056", "0", "2024/Jan/31 10:17", "Mistral Boilers", "Mistral", "CC3 26/35 plus", "", "", "2007", "current", "4", "1", "1", "2", "0", "", "", "2", "3", "2", "26", "35", "", "", "88.1", "82.0", "", "50.4", "", "2", "", "", "203", "1", "1", "230", "0", "2", "", "0", "35", "0", "25", "3", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.7", "95.2", "", "", "", "", "94.3"]} -{"pcdb_id": 15360, "brand_name": "Mistral", "model_name": "CS 26/40 Contract", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 58.7, "output_kw_max": 40.0, "final_year_of_manufacture": null, "raw": ["015360", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "CS 26/40 Contract", "", "", "2007", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "26", "40", "", "", "88.1", "80.3", "", "58.7", "", "2", "", "", "201", "1", "1", "230", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.7", "95.2", "", "", "", "", "94.3"]} -{"pcdb_id": 15361, "brand_name": "Mistral", "model_name": "CS3 26/35", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 58.7, "output_kw_max": 35.0, "final_year_of_manufacture": null, "raw": ["015361", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "CS3 26/35", "", "", "2007", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "26", "35", "", "", "88.1", "80.3", "", "58.7", "", "2", "", "", "201", "1", "1", "230", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.7", "95.2", "", "", "", "", "94.3"]} -{"pcdb_id": 15362, "brand_name": "Mistral", "model_name": "CS4 35/40", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 58.7, "output_kw_max": 40.0, "final_year_of_manufacture": null, "raw": ["015362", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "CS4 35/40", "", "", "2007", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "35", "40", "", "", "88.1", "80.3", "", "58.7", "", "2", "", "", "201", "1", "1", "230", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.7", "95.2", "", "", "", "", "94.3"]} -{"pcdb_id": 15363, "brand_name": "Mistral", "model_name": "CODSS 26/40 Contract", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 58.7, "output_kw_max": 40.0, "final_year_of_manufacture": null, "raw": ["015363", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "CODSS 26/40 Contract", "", "", "2007", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "26", "40", "", "", "88.1", "80.3", "", "58.7", "", "2", "", "", "201", "1", "1", "230", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.7", "95.2", "", "", "", "", "94.3"]} -{"pcdb_id": 15364, "brand_name": "Mistral", "model_name": "CODSS 4 35/40", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 58.7, "output_kw_max": 40.0, "final_year_of_manufacture": null, "raw": ["015364", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "CODSS 4 35/40", "", "", "2007", "current", "4", "1", "2", "1", "0", "", "", "2", "3", "2", "35", "40", "", "", "88.1", "80.3", "", "58.7", "", "2", "", "", "201", "1", "1", "230", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.7", "95.2", "", "", "", "", "94.3"]} -{"pcdb_id": 15365, "brand_name": "Mistral", "model_name": "CODSS 3 26/35", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 58.7, "output_kw_max": 35.0, "final_year_of_manufacture": null, "raw": ["015365", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "CODSS 3 26/35", "", "", "2007", "current", "4", "1", "2", "1", "0", "", "", "2", "3", "2", "26", "35", "", "", "88.1", "80.3", "", "58.7", "", "2", "", "", "201", "1", "1", "230", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.7", "95.2", "", "", "", "", "94.3"]} -{"pcdb_id": 15366, "brand_name": "Atlantic Boilers", "model_name": "KDB", "model_qualifier": "251 KCA", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 56.0, "output_kw_max": 28.4, "final_year_of_manufacture": null, "raw": ["015366", "000003", "0", "2023/Apr/27 08:50", "Atlantic 2000", "Atlantic Boilers", "KDB", "251 KCA", "", "2003", "obsolete", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "28.4", "28.4", "", "", "88.2", "79.6", "", "56.0", "", "2", "", "", "104", "1", "2", "145", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.5", "97.6", "", "", "", "", "95.7"]} -{"pcdb_id": 15367, "brand_name": "Atlantic Boilers", "model_name": "KDB", "model_qualifier": "201 KCA", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 55.9, "output_kw_max": 23.3, "final_year_of_manufacture": null, "raw": ["015367", "000003", "0", "2023/Apr/27 08:50", "Atlantic 2000", "Atlantic Boilers", "KDB", "201 KCA", "", "2003", "obsolete", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "23.3", "23.3", "", "", "88.1", "79.5", "", "55.9", "", "2", "", "", "104", "1", "2", "145", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.7", "97.3", "", "", "", "", "95.5"]} -{"pcdb_id": 15368, "brand_name": "Atlantic Boilers", "model_name": "KDB", "model_qualifier": "301 KCA", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 56.1, "output_kw_max": 33.8, "final_year_of_manufacture": null, "raw": ["015368", "000003", "0", "2023/Apr/27 08:50", "Atlantic 2000", "Atlantic Boilers", "KDB", "301 KCA", "", "2003", "obsolete", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "33.8", "33.8", "", "", "88.4", "79.8", "", "56.1", "", "2", "", "", "104", "1", "2", "145", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.3", "98.0", "", "", "", "", "96.0"]} -{"pcdb_id": 15369, "brand_name": "Atlantic Boilers", "model_name": "KDB", "model_qualifier": "181 KCA", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 56.0, "output_kw_max": 20.9, "final_year_of_manufacture": null, "raw": ["015369", "000003", "0", "2023/Apr/27 08:50", "Atlantic 2000", "Atlantic Boilers", "KDB", "181 KCA", "", "2003", "obsolete", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "20.9", "20.9", "", "", "88.3", "79.7", "", "56.0", "", "2", "", "", "104", "1", "2", "145", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "97.5", "", "", "", "", "95.7"]} -{"pcdb_id": 15370, "brand_name": "Ariston", "model_name": "Clas HE 24", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 56.0, "output_kw_max": 21.0, "final_year_of_manufacture": 2013, "raw": ["015370", "000080", "0", "2013/Nov/04 15:29", "Merloni TermoSanitari SpA", "Ariston", "Clas HE 24", "", "47-116-51", "2007", "2013", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "21", "21", "", "", "88.3", "79.7", "", "56.0", "", "2", "", "", "104", "1", "2", "120", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "97.3", "", "", "", "", "95.6"]} -{"pcdb_id": 15371, "brand_name": "Ariston", "model_name": "Clas HE 30", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 56.1, "output_kw_max": 27.0, "final_year_of_manufacture": 2013, "raw": ["015371", "000080", "0", "2013/Nov/04 15:29", "Merloni TermoSanitari SpA", "Ariston", "Clas HE 30", "", "47-116-52", "2007", "2013", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "27", "27", "", "", "88.3", "79.7", "", "56.1", "", "2", "", "", "104", "1", "2", "120", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "97.5", "", "", "", "", "95.7"]} -{"pcdb_id": 15372, "brand_name": "Ariston", "model_name": "Genus HE 24", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 56.0, "output_kw_max": 21.0, "final_year_of_manufacture": 2013, "raw": ["015372", "000080", "0", "2013/Nov/04 15:30", "Merloni TermoSanitari SpA", "Ariston", "Genus HE 24", "", "47-116-54", "2007", "2013", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "21", "21", "", "", "88.3", "79.7", "", "56.0", "", "2", "", "", "104", "1", "2", "120", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "97.3", "", "", "", "", "95.6"]} -{"pcdb_id": 15373, "brand_name": "Ariston", "model_name": "Genus HE 30", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 56.1, "output_kw_max": 27.0, "final_year_of_manufacture": 2013, "raw": ["015373", "000080", "0", "2013/Nov/04 15:29", "Merloni TermoSanitari SpA", "Ariston", "Genus HE 30", "", "47-116-55", "2007", "2013", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "27", "27", "", "", "88.3", "79.7", "", "56.1", "", "2", "", "", "104", "1", "2", "120", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "97.5", "", "", "", "", "95.7"]} -{"pcdb_id": 15374, "brand_name": "Potterton", "model_name": "Promax System", "model_qualifier": "12 HE Plus", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 78.9, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 12.0, "final_year_of_manufacture": 2008, "raw": ["015374", "000005", "0", "2012/Mar/27 10:12", "Baxi Heating", "Potterton", "Promax System", "12 HE Plus", "GC No. 41-591-90", "2007", "2008", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "12", "12", "", "", "87.9", "78.9", "", "57.7", "", "2", "", "", "102", "1", "2", "145", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "96.7", "", "", "", "", "95.0"]} -{"pcdb_id": 15375, "brand_name": "Potterton", "model_name": "Promax System", "model_qualifier": "15 HE Plus", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 15.0, "final_year_of_manufacture": 2008, "raw": ["015375", "000005", "0", "2012/Mar/27 10:12", "Baxi Heating", "Potterton", "Promax System", "15 HE Plus", "GC No. 41-591-91", "2007", "2008", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "15", "15", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "130", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "96.8", "", "", "", "", "95.1"]} -{"pcdb_id": 15376, "brand_name": "Potterton", "model_name": "Promax System", "model_qualifier": "18 HE Plus", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 18.0, "final_year_of_manufacture": 2008, "raw": ["015376", "000005", "0", "2012/Mar/27 10:12", "Baxi Heating", "Potterton", "Promax System", "18 HE Plus", "GC No. 41-591-92", "2007", "2008", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18", "18", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "140", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "96.9", "", "", "", "", "95.2"]} -{"pcdb_id": 15377, "brand_name": "Potterton", "model_name": "Promax System", "model_qualifier": "32 HE Plus", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 78.9, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 32.0, "final_year_of_manufacture": 2008, "raw": ["015377", "000005", "0", "2012/Mar/27 10:12", "Baxi Heating", "Potterton", "Promax System", "32 HE Plus", "GC No. 41-591-93", "2007", "2008", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "32", "32", "", "", "87.9", "78.9", "", "57.7", "", "2", "", "", "102", "1", "2", "160", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "96.7", "", "", "", "", "95.0"]} -{"pcdb_id": 15379, "brand_name": "Biasi", "model_name": "Riva 30 OV", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 30.0, "final_year_of_manufacture": null, "raw": ["015379", "000208", "0", "2012/Mar/27 10:12", "Halstead Boilers", "Biasi", "Riva 30 OV", "", "47-260-10", "2006", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "30", "30", "", "", "88.6", "79.6", "", "58.1", "", "2", "", "", "102", "1", "2", "50", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "98.3", "", "", "", "", "96.3"]} -{"pcdb_id": 15380, "brand_name": "Biasi", "model_name": "Riva 18 OV", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 18.0, "final_year_of_manufacture": null, "raw": ["015380", "000208", "0", "2012/Mar/27 10:12", "Halstead Boilers", "Biasi", "Riva 18 OV", "", "47-260-09", "2006", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18", "18", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "80", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.7", "97.9", "", "", "", "", "96.0"]} -{"pcdb_id": 15381, "brand_name": "Glow-worm", "model_name": "Ultrapower 100 SXI", "model_qualifier": "", "winter_efficiency_pct": 89.3, "summer_efficiency_pct": 82.0, "comparative_hot_water_efficiency_pct": 55.3, "output_kw_max": 24.3, "final_year_of_manufacture": null, "raw": ["015381", "000207", "0", "2024/Jan/31 10:17", "Vaillant Group UK", "Glow-worm", "Ultrapower 100 SXI", "", "", "2007", "current", "2", "1", "1", "2", "0", "", "", "2", "2", "2", "24.3", "24.3", "", "", "89.3", "82.0", "", "55.3", "", "2", "1", "", "106", "1", "2", "210", "15", "2", "1", "0", "80", "0", "50", "5", "62", "0.57", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "92.0", "98.9", "", "", "", "", "97.6"]} -{"pcdb_id": 15382, "brand_name": "Glow-worm", "model_name": "Ultrapower 170 SXI", "model_qualifier": "", "winter_efficiency_pct": 89.3, "summer_efficiency_pct": 82.0, "comparative_hot_water_efficiency_pct": 51.9, "output_kw_max": 24.3, "final_year_of_manufacture": null, "raw": ["015382", "000207", "0", "2024/Jan/31 10:17", "Vaillant Group UK", "Glow-worm", "Ultrapower 170 SXI", "", "", "2007", "current", "2", "1", "1", "2", "0", "", "", "2", "2", "2", "24.3", "24.3", "", "", "89.3", "82.0", "", "51.9", "", "2", "1", "", "106", "1", "2", "210", "15", "2", "1", "0", "120", "0", "50", "5", "62", "0.57", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "92.0", "98.9", "", "", "", "", "97.6"]} -{"pcdb_id": 15385, "brand_name": "Ariston", "model_name": "Genus HE 38", "model_qualifier": "", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 55.8, "output_kw_max": 30.0, "final_year_of_manufacture": 2013, "raw": ["015385", "000080", "0", "2014/Apr/15 14:59", "Merloni TermoSanitari SpA", "Ariston", "Genus HE 38", "", "47-116-56", "2007", "2013", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "30", "30", "", "", "87.9", "79.3", "", "55.8", "", "2", "", "", "104", "1", "2", "120", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "96.6", "", "", "", "", "94.9"]} -{"pcdb_id": 15386, "brand_name": "Ariston", "model_name": "Genus HE System 30", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 27.0, "final_year_of_manufacture": 2013, "raw": ["015386", "000080", "0", "2013/Nov/04 15:27", "Merloni TermoSanitari SpA", "Ariston", "Genus HE System 30", "", "41-116-25", "2007", "2013", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "27", "27", "", "", "88.3", "79.3", "", "57.9", "", "2", "", "", "102", "1", "2", "120", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "97.5", "", "", "", "", "95.7"]} -{"pcdb_id": 15387, "brand_name": "Ariston", "model_name": "Genus HE 24 System", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 21.0, "final_year_of_manufacture": 2013, "raw": ["015387", "000080", "0", "2013/Nov/04 15:26", "Merloni TermoSanitari SpA", "Ariston", "Genus HE 24 System", "", "41-116-24", "2007", "2013", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "21", "21", "", "", "88.3", "79.3", "", "57.9", "", "2", "", "", "102", "1", "2", "120", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "97.3", "", "", "", "", "95.6"]} -{"pcdb_id": 15388, "brand_name": "Ariston", "model_name": "Clas HE System 30", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 27.0, "final_year_of_manufacture": 2013, "raw": ["015388", "000080", "0", "2013/Nov/04 15:26", "Merloni TermoSanitari SpA", "Ariston", "Clas HE System 30", "", "41-116-23", "2007", "2013", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "27", "27", "", "", "88.3", "79.3", "", "57.9", "", "2", "", "", "102", "1", "2", "120", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "97.5", "", "", "", "", "95.7"]} -{"pcdb_id": 15389, "brand_name": "Ariston", "model_name": "Clas HE 24 System", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 21.0, "final_year_of_manufacture": 2013, "raw": ["015389", "000080", "0", "2013/Nov/04 15:27", "Merloni TermoSanitari SpA", "Ariston", "Clas HE 24 System", "", "41-116-22", "2007", "2013", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "21", "21", "", "", "88.3", "79.3", "", "57.9", "", "2", "", "", "102", "1", "2", "120", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "97.3", "", "", "", "", "95.6"]} -{"pcdb_id": 15391, "brand_name": "Ravenheat", "model_name": "CSI Primary 150 Low Nox", "model_qualifier": "", "winter_efficiency_pct": 89.3, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 58.7, "output_kw_max": 31.7, "final_year_of_manufacture": null, "raw": ["015391", "000026", "0", "2012/Mar/27 10:12", "Ravenheat", "Ravenheat", "CSI Primary 150 Low Nox", "", "", "2007", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "31.7", "31.7", "", "", "89.3", "80.3", "", "58.7", "", "2", "1", "", "102", "1", "2", "40", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "91.3", "99.2", "", "", "", "", "97.7"]} -{"pcdb_id": 15392, "brand_name": "Ravenheat", "model_name": "CSI Primary 150 Low Nox", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 31.7, "final_year_of_manufacture": null, "raw": ["015392", "000026", "0", "2012/Mar/27 10:12", "Ravenheat", "Ravenheat", "CSI Primary 150 Low Nox", "", "", "2007", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "31.7", "31.7", "", "", "88.3", "79.3", "", "57.9", "", "2", "", "", "102", "1", "2", "40", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.3", "97.0", "", "", "", "", "95.6"]} -{"pcdb_id": 15406, "brand_name": "Ravenheat", "model_name": "CSI 150 System T Low Nox", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 31.7, "final_year_of_manufacture": null, "raw": ["015406", "000026", "0", "2012/Mar/27 10:12", "Ravenheat", "Ravenheat", "CSI 150 System T Low Nox", "", "", "2007", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "31.7", "31.7", "", "", "88.3", "79.3", "", "57.9", "", "2", "", "", "102", "1", "2", "160", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.3", "97.0", "", "", "", "", "95.6"]} -{"pcdb_id": 15407, "brand_name": "Ravenheat", "model_name": "CSI 150 System T Low Nox", "model_qualifier": "", "winter_efficiency_pct": 89.3, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 58.7, "output_kw_max": 31.7, "final_year_of_manufacture": null, "raw": ["015407", "000026", "0", "2012/Mar/27 10:12", "Ravenheat", "Ravenheat", "CSI 150 System T Low Nox", "", "", "2007", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "31.7", "31.7", "", "", "89.3", "80.3", "", "58.7", "", "2", "1", "", "102", "1", "2", "160", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "91.3", "99.2", "", "", "", "", "97.7"]} -{"pcdb_id": 15421, "brand_name": "Ravenheat", "model_name": "CSI 150 T Low Nox", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 56.1, "output_kw_max": 31.7, "final_year_of_manufacture": null, "raw": ["015421", "000026", "0", "2010/Oct/12 11:55", "Ravenheat", "Ravenheat", "CSI 150 T Low Nox", "", "", "2007", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "31.7", "31.7", "", "", "88.3", "79.7", "", "56.1", "", "2", "", "", "104", "1", "2", "160", "0", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.3", "97.0", "", "", "", "", "95.6"]} -{"pcdb_id": 15422, "brand_name": "Ravenheat", "model_name": "CSI 150 T Low Nox", "model_qualifier": "", "winter_efficiency_pct": 89.3, "summer_efficiency_pct": 80.7, "comparative_hot_water_efficiency_pct": 56.8, "output_kw_max": 31.7, "final_year_of_manufacture": null, "raw": ["015422", "000026", "0", "2010/Sep/29 12:24", "Ravenheat", "Ravenheat", "CSI 150 T Low Nox", "", "", "2007", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "31.7", "31.7", "", "", "89.3", "80.7", "", "56.8", "", "2", "1", "", "104", "1", "2", "160", "0", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "91.3", "99.2", "", "", "", "", "97.7"]} -{"pcdb_id": 15425, "brand_name": "Vaillant", "model_name": "ecoTEC plus 837", "model_qualifier": "", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 56.0, "output_kw_max": 28.0, "final_year_of_manufacture": 2012, "raw": ["015425", "000031", "0", "2019/Mar/04 10:17", "Vaillant", "Vaillant", "ecoTEC plus 837", "", "47- 044-33", "2007", "2012", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28.0", "28.0", "", "", "88.2", "79.6", "", "56.0", "", "2", "", "", "104", "1", "2", "155", "6", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.0", "96.4", "", "", "", "", "95.2"]} -{"pcdb_id": 15426, "brand_name": "Vaillant", "model_name": "ecoTEC plus 637", "model_qualifier": "", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 37.0, "final_year_of_manufacture": 2019, "raw": ["015426", "000031", "0", "2019/Mar/04 10:11", "Vaillant", "Vaillant", "ecoTEC plus 637", "", "41-044-49", "2007", "2019", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "37.0", "37.0", "", "", "88.2", "79.2", "", "57.9", "", "2", "", "", "102", "1", "2", "155", "6", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.0", "96.5", "", "", "", "", "95.3"]} -{"pcdb_id": 15428, "brand_name": "Vaillant", "model_name": "ecoTEC plus 937", "model_qualifier": "", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 81.9, "comparative_hot_water_efficiency_pct": 53.3, "output_kw_max": 28.0, "final_year_of_manufacture": 2019, "raw": ["015428", "000031", "0", "2024/Jan/31 10:17", "Vaillant", "Vaillant", "ecoTEC plus 937", "", "", "2007", "2019", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "28.0", "28.0", "", "", "89.2", "81.9", "", "53.3", "", "2", "1", "", "106", "1", "2", "175", "6.5", "2", "1", "0", "15", "0", "30", "5", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "92.0", "98.5", "", "", "", "", "97.3"]} -{"pcdb_id": 15429, "brand_name": "Vaillant", "model_name": "ecoTEC plus 937", "model_qualifier": "", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 80.9, "comparative_hot_water_efficiency_pct": 52.6, "output_kw_max": 28.0, "final_year_of_manufacture": 2012, "raw": ["015429", "000031", "0", "2024/Jan/31 10:17", "Vaillant", "Vaillant", "ecoTEC plus 937", "", "47- 044-39", "2007", "2012", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28.0", "28.0", "", "", "88.2", "80.9", "", "52.6", "", "2", "", "", "106", "1", "2", "175", "6.5", "2", "1", "0", "15", "0", "30", "5", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.0", "96.4", "", "", "", "", "95.2"]} -{"pcdb_id": 15430, "brand_name": "Vaillant", "model_name": "ecoTEC plus 837", "model_qualifier": "", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 80.6, "comparative_hot_water_efficiency_pct": 56.7, "output_kw_max": 28.0, "final_year_of_manufacture": 2019, "raw": ["015430", "000031", "0", "2019/Mar/04 10:16", "Vaillant", "Vaillant", "ecoTEC plus 837", "", "", "2007", "2019", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "28.0", "28.0", "", "", "89.2", "80.6", "", "56.7", "", "2", "1", "", "104", "1", "2", "155", "6", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "92.0", "98.5", "", "", "", "", "97.3"]} -{"pcdb_id": 15431, "brand_name": "Vaillant", "model_name": "ecoTEC plus 637", "model_qualifier": "", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 37.0, "final_year_of_manufacture": 2019, "raw": ["015431", "000031", "0", "2019/Mar/04 10:10", "Vaillant", "Vaillant", "ecoTEC plus 637", "", "", "2007", "2019", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "37.0", "37.0", "", "", "89.2", "80.2", "", "58.6", "", "2", "1", "", "102", "1", "2", "155", "6", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "92.0", "98.5", "", "", "", "", "97.3"]} -{"pcdb_id": 15433, "brand_name": "Glow-worm", "model_name": "Ultracom 38hxi", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 38.0, "final_year_of_manufacture": null, "raw": ["015433", "000207", "0", "2012/Mar/27 10:12", "Vaillant Group UK", "Glow-worm", "Ultracom 38hxi", "", "41-019-06", "2007", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "38.00", "38.00", "", "", "88.5", "79.5", "", "58.1", "", "2", "", "", "102", "1", "2", "60", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.3", "97.5", "", "", "", "", "95.9"]} -{"pcdb_id": 15436, "brand_name": "Glow-worm", "model_name": "Ultracom 38hxi", "model_qualifier": "", "winter_efficiency_pct": 89.5, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 58.8, "output_kw_max": 38.0, "final_year_of_manufacture": null, "raw": ["015436", "000207", "0", "2012/Mar/27 10:12", "Vaillant Group UK", "Glow-worm", "Ultracom 38hxi", "", "", "2007", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "38.00", "38.00", "", "", "89.5", "80.5", "", "58.8", "", "2", "1", "", "102", "1", "2", "60", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "91.3", "99.7", "", "", "", "", "98.1"]} -{"pcdb_id": 15437, "brand_name": "Glow-worm", "model_name": "Ultracom 38cxi", "model_qualifier": "", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 55.8, "output_kw_max": 30.0, "final_year_of_manufacture": 2013, "raw": ["015437", "000207", "0", "2013/Aug/23 09:31", "Vaillant Group UK", "Glow-worm", "Ultracom 38cxi", "", "47-019-03", "2007", "2013", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "30.0", "30.0", "", "", "87.9", "79.3", "", "55.8", "", "2", "", "", "104", "1", "2", "180", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.7", "96.3", "", "", "", "", "94.9"]} -{"pcdb_id": 15438, "brand_name": "Glow-worm", "model_name": "Ultracom 38cxi", "model_qualifier": "", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 56.5, "output_kw_max": 30.0, "final_year_of_manufacture": null, "raw": ["015438", "000207", "0", "2010/Mar/06 17:44", "Vaillant Group UK", "Glow-worm", "Ultracom 38cxi", "", "", "2007", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "30.0", "30.0", "", "", "88.9", "80.3", "", "56.5", "", "2", "1", "", "104", "1", "2", "180", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.7", "98.5", "", "", "", "", "97.0"]} -{"pcdb_id": 15440, "brand_name": "Glow-worm", "model_name": "Ultracom 30sxi", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 28.17, "final_year_of_manufacture": 2013, "raw": ["015440", "000207", "0", "2013/Aug/23 09:31", "Vaillant Group UK", "Glow-worm", "Ultracom 30sxi", "", "41-019-08", "2007", "2013", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "28.17", "28.17", "", "", "88.1", "79.1", "", "57.8", "", "2", "", "", "102", "1", "2", "180", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.7", "96.9", "", "", "", "", "95.3"]} -{"pcdb_id": 15442, "brand_name": "Glow-worm", "model_name": "Ultracom 30sxi", "model_qualifier": "", "winter_efficiency_pct": 90.0, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 59.2, "output_kw_max": 28.17, "final_year_of_manufacture": null, "raw": ["015442", "000207", "0", "2012/Mar/27 10:12", "Vaillant Group UK", "Glow-worm", "Ultracom 30sxi", "", "", "2007", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "28.17", "28.17", "", "", "90.0", "81.0", "", "59.2", "", "2", "0", "", "102", "1", "2", "180", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.8", "99.0", "", "", "", "", "97.3"]} -{"pcdb_id": 15443, "brand_name": "Glow-worm", "model_name": "Ultracom 30hxi", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 28.17, "final_year_of_manufacture": null, "raw": ["015443", "000207", "0", "2012/Mar/27 10:12", "Vaillant Group UK", "Glow-worm", "Ultracom 30hxi", "", "41-019-05", "2007", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "28.17", "28.17", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "60", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0085", "", "", "", "", "", "", "", "", "88.7", "96.4", "", "", "", "", "95.0"]} -{"pcdb_id": 15444, "brand_name": "Glow-worm", "model_name": "Ultracom 30hxi", "model_qualifier": "", "winter_efficiency_pct": 89.8, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 59.0, "output_kw_max": 28.17, "final_year_of_manufacture": null, "raw": ["015444", "000207", "0", "2012/Mar/27 10:12", "Vaillant Group UK", "Glow-worm", "Ultracom 30hxi", "", "", "2007", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "28.17", "28.17", "", "", "89.8", "80.8", "", "59.0", "", "2", "0", "", "102", "1", "2", "60", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.8", "98.5", "", "", "", "", "96.9"]} -{"pcdb_id": 15445, "brand_name": "Glow-worm", "model_name": "Ultracom 30cxi", "model_qualifier": "", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 55.8, "output_kw_max": 22.94, "final_year_of_manufacture": 2013, "raw": ["015445", "000207", "0", "2013/Aug/23 09:31", "Vaillant Group UK", "Glow-worm", "Ultracom 30cxi", "", "47-019-02", "2007", "2013", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "22.94", "22.94", "", "", "87.9", "79.3", "", "55.8", "", "2", "", "", "104", "1", "2", "180", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "96.4", "", "", "", "", "94.9"]} -{"pcdb_id": 15447, "brand_name": "Glow-worm", "model_name": "Ultracom 30cxi", "model_qualifier": "", "winter_efficiency_pct": 90.1, "summer_efficiency_pct": 81.5, "comparative_hot_water_efficiency_pct": 57.3, "output_kw_max": 22.94, "final_year_of_manufacture": null, "raw": ["015447", "000207", "0", "2010/Mar/06 17:45", "Vaillant Group UK", "Glow-worm", "Ultracom 30cxi", "", "", "2007", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "22.94", "22.94", "", "", "90.1", "81.5", "", "57.3", "", "2", "0", "", "104", "1", "2", "180", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.1", "99.0", "", "", "", "", "97.3"]} -{"pcdb_id": 15448, "brand_name": "Glow-worm", "model_name": "Ultracom 30cx", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 55.9, "output_kw_max": 22.94, "final_year_of_manufacture": 2013, "raw": ["015448", "000207", "0", "2013/Aug/23 09:31", "Vaillant Group UK", "Glow-worm", "Ultracom 30cx", "", "47-019-07", "2007", "2013", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "22.94", "22.94", "", "", "88.1", "79.5", "", "55.9", "", "2", "", "", "104", "1", "2", "180", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "96.9", "", "", "", "", "95.2"]} -{"pcdb_id": 15450, "brand_name": "Glow-worm", "model_name": "Ultracom 30cx", "model_qualifier": "", "winter_efficiency_pct": 90.1, "summer_efficiency_pct": 81.5, "comparative_hot_water_efficiency_pct": 57.3, "output_kw_max": 22.94, "final_year_of_manufacture": null, "raw": ["015450", "000207", "0", "2010/Mar/06 17:45", "Vaillant Group UK", "Glow-worm", "Ultracom 30cx", "", "", "2007", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "22.94", "22.94", "", "", "90.1", "81.5", "", "57.3", "", "2", "0", "", "104", "1", "2", "180", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.1", "99.0", "", "", "", "", "97.3"]} -{"pcdb_id": 15451, "brand_name": "Glow-worm", "model_name": "Ultracom 24hxi", "model_qualifier": "", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 24.0, "final_year_of_manufacture": null, "raw": ["015451", "000207", "0", "2012/Mar/27 10:12", "Vaillant Group UK", "Glow-worm", "Ultracom 24hxi", "", "41-019-04", "", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24.00", "24.00", "", "", "88.2", "79.2", "", "57.9", "", "2", "", "", "102", "1", "2", "60", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0085", "", "", "", "", "", "", "", "", "88.7", "97.0", "", "", "", "", "95.4"]} -{"pcdb_id": 15452, "brand_name": "Glow-worm", "model_name": "Ultracom 24hxi", "model_qualifier": "", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 24.0, "final_year_of_manufacture": null, "raw": ["015452", "000207", "0", "2012/Mar/27 10:12", "Vaillant Group UK", "Glow-worm", "Ultracom 24hxi", "", "", "2007", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "24.00", "24.00", "", "", "89.2", "80.2", "", "58.6", "", "2", "1", "", "102", "1", "2", "60", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.6", "99.2", "", "", "", "", "97.6"]} -{"pcdb_id": 15453, "brand_name": "Glow-worm", "model_name": "Ultracom 24cxi", "model_qualifier": "", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 55.8, "output_kw_max": 18.0, "final_year_of_manufacture": 2013, "raw": ["015453", "000207", "0", "2013/Aug/23 09:31", "Vaillant Group UK", "Glow-worm", "Ultracom 24cxi", "", "47-019-01", "2007", "2013", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "18.0", "18.0", "", "", "87.9", "79.3", "", "55.8", "", "2", "", "", "104", "1", "2", "180", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.6", "96.3", "", "", "", "", "94.8"]} -{"pcdb_id": 15454, "brand_name": "Glow-worm", "model_name": "Ultracom 24cxi", "model_qualifier": "", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 56.5, "output_kw_max": 18.0, "final_year_of_manufacture": null, "raw": ["015454", "000207", "0", "2010/Mar/06 17:46", "Vaillant Group UK", "Glow-worm", "Ultracom 24cxi", "", "", "2007", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "18.0", "18.0", "", "", "88.9", "80.3", "", "56.5", "", "2", "1", "", "104", "1", "2", "180", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.5", "98.5", "", "", "", "", "96.9"]} -{"pcdb_id": 15455, "brand_name": "Glow-worm", "model_name": "Ultracom 24cx", "model_qualifier": "", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 55.8, "output_kw_max": 18.0, "final_year_of_manufacture": 2013, "raw": ["015455", "000207", "0", "2013/Aug/23 09:30", "Vaillant Group UK", "Glow-worm", "Ultracom 24cx", "", "47-019-06", "2007", "2013", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "18.0", "18.0", "", "", "87.9", "79.3", "", "55.8", "", "2", "", "", "104", "1", "2", "180", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.6", "96.3", "", "", "", "", "94.8"]} -{"pcdb_id": 15456, "brand_name": "Glow-worm", "model_name": "Ultracom 24cx", "model_qualifier": "", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 56.5, "output_kw_max": 18.0, "final_year_of_manufacture": null, "raw": ["015456", "000207", "0", "2010/Mar/06 17:46", "Vaillant Group UK", "Glow-worm", "Ultracom 24cx", "", "", "2007", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "18.0", "18.0", "", "", "88.9", "80.3", "", "56.5", "", "2", "1", "", "104", "1", "2", "180", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.5", "98.5", "", "", "", "", "96.9"]} -{"pcdb_id": 15458, "brand_name": "Glow-worm", "model_name": "Ultracom 18sxi", "model_qualifier": "", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 78.9, "comparative_hot_water_efficiency_pct": 57.6, "output_kw_max": 18.57, "final_year_of_manufacture": 2013, "raw": ["015458", "000207", "0", "2013/Aug/23 09:30", "Vaillant Group UK", "Glow-worm", "Ultracom 18sxi", "", "41-019-07", "2007", "2013", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18.57", "18.57", "", "", "87.9", "78.9", "", "57.6", "", "2", "", "", "102", "1", "2", "180", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0085", "", "", "", "", "", "", "", "", "88.6", "96.3", "", "", "", "", "94.8"]} -{"pcdb_id": 15459, "brand_name": "Glow-worm", "model_name": "Ultracom 18sxi", "model_qualifier": "", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 18.57, "final_year_of_manufacture": null, "raw": ["015459", "000207", "0", "2012/Mar/27 10:12", "Vaillant Group UK", "Glow-worm", "Ultracom 18sxi", "", "", "2007", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "18.57", "18.57", "", "", "88.9", "79.9", "", "58.4", "", "2", "1", "", "102", "1", "2", "180", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.5", "98.5", "", "", "", "", "96.9"]} -{"pcdb_id": 15460, "brand_name": "Glow-worm", "model_name": "Ultracom 18hxi", "model_qualifier": "", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 78.9, "comparative_hot_water_efficiency_pct": 57.6, "output_kw_max": 18.57, "final_year_of_manufacture": null, "raw": ["015460", "000207", "0", "2012/Mar/27 10:12", "Vaillant Group UK", "Glow-worm", "Ultracom 18hxi", "", "41-019-03", "2007", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18.57", "18.57", "", "", "87.9", "78.9", "", "57.6", "", "2", "", "", "102", "1", "2", "60", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.6", "96.3", "", "", "", "", "94.8"]} -{"pcdb_id": 15461, "brand_name": "Glow-worm", "model_name": "Ultracom 18hxi", "model_qualifier": "", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 18.57, "final_year_of_manufacture": null, "raw": ["015461", "000207", "0", "2012/Mar/27 10:12", "Vaillant Group UK", "Glow-worm", "Ultracom 18hxi", "", "", "2007", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "18.57", "18.57", "", "", "88.9", "79.9", "", "58.4", "", "2", "1", "", "102", "1", "2", "60", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.5", "98.5", "", "", "", "", "96.9"]} -{"pcdb_id": 15462, "brand_name": "Glow-worm", "model_name": "Ultracom 15hxi", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 15.0, "final_year_of_manufacture": null, "raw": ["015462", "000207", "0", "2012/Mar/27 10:12", "Vaillant Group UK", "Glow-worm", "Ultracom 15hxi", "", "41-019-02", "2007", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "15.00", "15.00", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "60", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0085", "", "", "", "", "", "", "", "", "88.6", "96.5", "", "", "", "", "95.0"]} -{"pcdb_id": 15463, "brand_name": "Glow-worm", "model_name": "Ultracom 15hxi", "model_qualifier": "", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 15.0, "final_year_of_manufacture": null, "raw": ["015463", "000207", "0", "2012/Mar/27 10:12", "Vaillant Group UK", "Glow-worm", "Ultracom 15hxi", "", "", "2007", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "15.00", "15.00", "", "", "89.0", "80.0", "", "58.4", "", "2", "1", "", "102", "1", "2", "60", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.5", "98.6", "", "", "", "", "97.1"]} -{"pcdb_id": 15464, "brand_name": "Glow-worm", "model_name": "Ultracom 12hxi", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 12.0, "final_year_of_manufacture": null, "raw": ["015464", "000207", "0", "2012/Mar/27 10:12", "Vaillant Group UK", "Glow-worm", "Ultracom 12hxi", "", "41-019-01", "2007", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "12.00", "12.00", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "60", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0085", "", "", "", "", "", "", "", "", "88.7", "96.5", "", "", "", "", "95.0"]} -{"pcdb_id": 15465, "brand_name": "Glow-worm", "model_name": "Ultracom 12hxi", "model_qualifier": "", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 12.0, "final_year_of_manufacture": null, "raw": ["015465", "000207", "0", "2012/Mar/27 10:12", "Vaillant Group UK", "Glow-worm", "Ultracom 12hxi", "", "", "2007", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "12.00", "12.00", "", "", "89.0", "80.0", "", "58.4", "", "2", "1", "", "102", "1", "2", "60", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.6", "98.6", "", "", "", "", "97.1"]} -{"pcdb_id": 15466, "brand_name": "Thermeco", "model_name": "BWIC 12/16", "model_qualifier": "", "winter_efficiency_pct": 86.1, "summer_efficiency_pct": 78.3, "comparative_hot_water_efficiency_pct": 57.2, "output_kw_max": 16.0, "final_year_of_manufacture": null, "raw": ["015466", "000051", "0", "2012/Mar/27 10:12", "GAH Heating Products", "Thermeco", "BWIC 12/16", "", "", "2007", "current", "4", "2", "1", "1", "0", "", "", "2", "3", "2", "12", "16", "", "", "86.1", "78.3", "", "57.2", "", "2", "", "", "201", "1", "1", "75", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "88.9", "91.2", "", "", "", "", "90.7"]} -{"pcdb_id": 15467, "brand_name": "Thermeco", "model_name": "BFIC 12/24", "model_qualifier": "", "winter_efficiency_pct": 87.6, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 23.0, "final_year_of_manufacture": null, "raw": ["015467", "000051", "0", "2012/Mar/27 10:12", "GAH Heating Products", "Thermeco", "BFIC 12/24", "", "", "2007", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "12", "23", "", "", "87.6", "79.8", "", "58.3", "", "2", "", "", "201", "1", "1", "75", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.3", "94.1", "", "", "", "", "93.4"]} -{"pcdb_id": 15468, "brand_name": "Thermeco", "model_name": "BFISC 12/24", "model_qualifier": "", "winter_efficiency_pct": 87.6, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 23.0, "final_year_of_manufacture": null, "raw": ["015468", "000051", "0", "2012/Mar/27 10:12", "GAH Heating Products", "Thermeco", "BFISC 12/24", "", "", "2007", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "12", "23", "", "", "87.6", "79.8", "", "58.3", "", "2", "", "", "201", "1", "1", "75", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.3", "94.1", "", "", "", "", "93.4"]} -{"pcdb_id": 15469, "brand_name": "Thermeco", "model_name": "BFEC 12/24", "model_qualifier": "", "winter_efficiency_pct": 87.6, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 23.0, "final_year_of_manufacture": null, "raw": ["015469", "000051", "0", "2012/Mar/27 10:12", "GAH Heating Products", "Thermeco", "BFEC 12/24", "", "", "2007", "current", "4", "1", "2", "1", "0", "", "", "2", "1", "2", "12", "23", "", "", "87.6", "79.8", "", "58.3", "", "2", "", "", "201", "1", "1", "75", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.3", "94.1", "", "", "", "", "93.4"]} -{"pcdb_id": 15470, "brand_name": "Thermeco", "model_name": "BFESC 12/24", "model_qualifier": "", "winter_efficiency_pct": 87.6, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 23.0, "final_year_of_manufacture": null, "raw": ["015470", "000051", "0", "2012/Mar/27 10:12", "GAH Heating Products", "Thermeco", "BFESC 12/24", "", "", "2007", "current", "4", "1", "2", "1", "0", "", "", "2", "1", "2", "12", "23", "", "", "87.6", "79.8", "", "58.3", "", "2", "", "", "201", "1", "1", "75", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.3", "94.1", "", "", "", "", "93.4"]} -{"pcdb_id": 15471, "brand_name": "Thermeco", "model_name": "BWEC 12/16", "model_qualifier": "", "winter_efficiency_pct": 86.1, "summer_efficiency_pct": 78.3, "comparative_hot_water_efficiency_pct": 57.2, "output_kw_max": 16.0, "final_year_of_manufacture": null, "raw": ["015471", "000051", "0", "2012/Mar/27 10:12", "GAH Heating Products", "Thermeco", "BWEC 12/16", "", "", "2007", "current", "4", "2", "2", "1", "0", "", "", "2", "1", "2", "12", "16", "", "", "86.1", "78.3", "", "57.2", "", "2", "", "", "201", "1", "1", "75", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "88.9", "91.2", "", "", "", "", "90.7"]} -{"pcdb_id": 15472, "brand_name": "Thermeco", "model_name": "BWESC 12/16", "model_qualifier": "", "winter_efficiency_pct": 86.1, "summer_efficiency_pct": 78.3, "comparative_hot_water_efficiency_pct": 57.2, "output_kw_max": 16.0, "final_year_of_manufacture": null, "raw": ["015472", "000051", "0", "2012/Mar/27 10:12", "GAH Heating Products", "Thermeco", "BWESC 12/16", "", "", "2007", "current", "4", "2", "2", "1", "0", "", "", "2", "1", "2", "12", "16", "", "", "86.1", "78.3", "", "57.2", "", "2", "", "", "201", "1", "1", "75", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "88.9", "91.2", "", "", "", "", "90.7"]} -{"pcdb_id": 15473, "brand_name": "Thermeco", "model_name": "BWISC 12/16", "model_qualifier": "", "winter_efficiency_pct": 86.1, "summer_efficiency_pct": 78.3, "comparative_hot_water_efficiency_pct": 57.2, "output_kw_max": 16.0, "final_year_of_manufacture": null, "raw": ["015473", "000051", "0", "2012/Mar/27 10:12", "GAH Heating Products", "Thermeco", "BWISC 12/16", "", "", "2007", "current", "4", "2", "1", "1", "0", "", "", "2", "3", "2", "12", "16", "", "", "86.1", "78.3", "", "57.2", "", "2", "", "", "201", "1", "1", "75", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "88.9", "91.2", "", "", "", "", "90.7"]} -{"pcdb_id": 15474, "brand_name": "Turco", "model_name": "Ambassador", "model_qualifier": "15/21 Kitchen", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 81.4, "comparative_hot_water_efficiency_pct": 59.5, "output_kw_max": 22.3, "final_year_of_manufacture": null, "raw": ["015474", "000218", "0", "2012/Mar/27 10:12", "Turkington Engineering", "Turco", "Ambassador", "15/21 Kitchen", "", "2007", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "15", "22.3", "", "", "89.2", "81.4", "", "59.5", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.3", "97.7", "", "", "", "", "96.5"]} -{"pcdb_id": 15475, "brand_name": "Turco", "model_name": "Countryman", "model_qualifier": "15/21 Outdoor Combi", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 81.8, "comparative_hot_water_efficiency_pct": 57.5, "output_kw_max": 22.3, "final_year_of_manufacture": null, "raw": ["015475", "000218", "0", "2007/Jul/20 08:44", "Turkington Engineering", "Turco", "Countryman", "15/21 Outdoor Combi", "", "2007", "current", "4", "1", "2", "2", "0", "", "", "2", "3", "1", "15", "22.3", "", "", "89.2", "81.8", "", "57.5", "", "2", "", "", "202", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.3", "97.7", "", "", "", "", "96.5"]} -{"pcdb_id": 15476, "brand_name": "Turco", "model_name": "Senator", "model_qualifier": "15/21 Combi", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 81.8, "comparative_hot_water_efficiency_pct": 57.5, "output_kw_max": 22.3, "final_year_of_manufacture": null, "raw": ["015476", "000218", "0", "2007/Jul/20 08:44", "Turkington Engineering", "Turco", "Senator", "15/21 Combi", "", "2007", "current", "4", "1", "2", "2", "0", "", "", "2", "3", "1", "15", "22.3", "", "", "89.2", "81.8", "", "57.5", "", "2", "", "", "202", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.3", "97.7", "", "", "", "", "96.5"]} -{"pcdb_id": 15477, "brand_name": "Turco", "model_name": "Countryman", "model_qualifier": "15/21 Slimline Outdoor", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 81.4, "comparative_hot_water_efficiency_pct": 59.5, "output_kw_max": 22.3, "final_year_of_manufacture": null, "raw": ["015477", "000218", "0", "2012/Mar/27 10:12", "Turkington Engineering", "Turco", "Countryman", "15/21 Slimline Outdoor", "", "2007", "current", "4", "1", "2", "1", "0", "", "", "2", "3", "1", "15", "22.3", "", "", "89.2", "81.4", "", "59.5", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.3", "97.7", "", "", "", "", "96.5"]} -{"pcdb_id": 15478, "brand_name": "Turco", "model_name": "Consul", "model_qualifier": "15/21 Boilerhouse", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 81.4, "comparative_hot_water_efficiency_pct": 59.5, "output_kw_max": 22.3, "final_year_of_manufacture": null, "raw": ["015478", "000218", "0", "2012/Mar/27 10:12", "Turkington Engineering", "Turco", "Consul", "15/21 Boilerhouse", "", "2007", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "15", "22.3", "", "", "89.2", "81.4", "", "59.5", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.3", "97.7", "", "", "", "", "96.5"]} -{"pcdb_id": 15479, "brand_name": "Eurocal", "model_name": "Countryman", "model_qualifier": "15/21 Outdoor Combi", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 81.8, "comparative_hot_water_efficiency_pct": 57.5, "output_kw_max": 22.3, "final_year_of_manufacture": null, "raw": ["015479", "000218", "0", "2007/Jul/20 08:49", "Turkington Engineering", "Eurocal", "Countryman", "15/21 Outdoor Combi", "", "2007", "current", "4", "1", "2", "2", "0", "", "", "2", "3", "1", "15", "22.3", "", "", "89.2", "81.8", "", "57.5", "", "2", "", "", "202", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.3", "97.7", "", "", "", "", "96.5"]} -{"pcdb_id": 15480, "brand_name": "Eurocal", "model_name": "Senator", "model_qualifier": "15/21 Combi", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 81.8, "comparative_hot_water_efficiency_pct": 57.5, "output_kw_max": 22.3, "final_year_of_manufacture": null, "raw": ["015480", "000218", "0", "2007/Jul/20 08:50", "Turkington Engineering", "Eurocal", "Senator", "15/21 Combi", "", "2007", "current", "4", "1", "1", "2", "0", "", "", "2", "3", "1", "15", "22.3", "", "", "89.2", "81.8", "", "57.5", "", "2", "", "", "202", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.3", "97.7", "", "", "", "", "96.5"]} -{"pcdb_id": 15481, "brand_name": "Eurocal", "model_name": "Countryman", "model_qualifier": "15/21 Slimline Outdoor", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 81.4, "comparative_hot_water_efficiency_pct": 59.5, "output_kw_max": 22.3, "final_year_of_manufacture": null, "raw": ["015481", "000218", "0", "2012/Mar/27 10:12", "Turkington Engineering", "Eurocal", "Countryman", "15/21 Slimline Outdoor", "", "2007", "current", "4", "1", "2", "1", "0", "", "", "2", "3", "1", "15", "22.3", "", "", "89.2", "81.4", "", "59.5", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.3", "97.7", "", "", "", "", "96.5"]} -{"pcdb_id": 15482, "brand_name": "Eurocal", "model_name": "Ambassador", "model_qualifier": "15/21 Kitchen", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 81.4, "comparative_hot_water_efficiency_pct": 59.5, "output_kw_max": 22.3, "final_year_of_manufacture": null, "raw": ["015482", "000218", "0", "2012/Mar/27 10:12", "Turkington Engineering", "Eurocal", "Ambassador", "15/21 Kitchen", "", "2007", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "15", "22.3", "", "", "89.2", "81.4", "", "59.5", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.3", "97.7", "", "", "", "", "96.5"]} -{"pcdb_id": 15483, "brand_name": "Turco", "model_name": "Ambassador", "model_qualifier": "21/27 Kitchen", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 59.2, "output_kw_max": 27.9, "final_year_of_manufacture": null, "raw": ["015483", "000218", "0", "2012/Mar/27 10:12", "Turkington Engineering", "Turco", "Ambassador", "21/27 Kitchen", "", "2007", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "21", "27.9", "", "", "88.8", "81.0", "", "59.2", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "89.5", "97.4", "", "", "", "", "95.9"]} -{"pcdb_id": 15484, "brand_name": "Turco", "model_name": "Countryman", "model_qualifier": "21/27 Outdoor Combi", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 81.4, "comparative_hot_water_efficiency_pct": 57.3, "output_kw_max": 27.9, "final_year_of_manufacture": null, "raw": ["015484", "000218", "0", "2007/Jul/20 08:52", "Turkington Engineering", "Turco", "Countryman", "21/27 Outdoor Combi", "", "2007", "current", "4", "1", "2", "2", "0", "", "", "2", "3", "1", "21", "27.9", "", "", "88.8", "81.4", "", "57.3", "", "2", "", "", "202", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "89.5", "97.4", "", "", "", "", "95.9"]} -{"pcdb_id": 15485, "brand_name": "Turco", "model_name": "Senator", "model_qualifier": "21/27 Combi", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 81.4, "comparative_hot_water_efficiency_pct": 57.3, "output_kw_max": 27.9, "final_year_of_manufacture": null, "raw": ["015485", "000218", "0", "2007/Jul/20 08:52", "Turkington Engineering", "Turco", "Senator", "21/27 Combi", "", "2007", "current", "4", "1", "1", "2", "0", "", "", "2", "3", "1", "21", "27.9", "", "", "88.8", "81.4", "", "57.3", "", "2", "", "", "202", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "89.5", "97.4", "", "", "", "", "95.9"]} -{"pcdb_id": 15486, "brand_name": "Turco", "model_name": "Countryman", "model_qualifier": "21/27 Slimline Outdoor", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 59.2, "output_kw_max": 27.9, "final_year_of_manufacture": null, "raw": ["015486", "000218", "0", "2012/Mar/27 10:12", "Turkington Engineering", "Turco", "Countryman", "21/27 Slimline Outdoor", "", "2007", "current", "4", "1", "2", "1", "0", "", "", "2", "3", "1", "21", "27.9", "", "", "88.8", "81.0", "", "59.2", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "89.5", "97.4", "", "", "", "", "95.9"]} -{"pcdb_id": 15487, "brand_name": "Eurocal", "model_name": "Countryman", "model_qualifier": "21/27 Outdoor Combi", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 81.4, "comparative_hot_water_efficiency_pct": 57.3, "output_kw_max": 27.9, "final_year_of_manufacture": null, "raw": ["015487", "000218", "0", "2007/Jul/20 08:53", "Turkington Engineering", "Eurocal", "Countryman", "21/27 Outdoor Combi", "", "2007", "current", "4", "1", "2", "2", "0", "", "", "2", "3", "1", "21", "27.9", "", "", "88.8", "81.4", "", "57.3", "", "2", "", "", "202", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "89.5", "97.4", "", "", "", "", "95.9"]} -{"pcdb_id": 15488, "brand_name": "Eurocal", "model_name": "Senator", "model_qualifier": "21/27 Combi", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 81.4, "comparative_hot_water_efficiency_pct": 57.3, "output_kw_max": 27.9, "final_year_of_manufacture": null, "raw": ["015488", "000218", "0", "2007/Jul/20 08:53", "Turkington Engineering", "Eurocal", "Senator", "21/27 Combi", "", "2007", "current", "4", "1", "1", "2", "0", "", "", "2", "3", "1", "21", "27.9", "", "", "88.8", "81.4", "", "57.3", "", "2", "", "", "202", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "89.5", "97.4", "", "", "", "", "95.9"]} -{"pcdb_id": 15489, "brand_name": "Eurocal", "model_name": "Countryman", "model_qualifier": "21/27 Slimline Outdoor", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 59.2, "output_kw_max": 27.9, "final_year_of_manufacture": null, "raw": ["015489", "000218", "0", "2012/Mar/27 10:12", "Turkington Engineering", "Eurocal", "Countryman", "21/27 Slimline Outdoor", "", "2007", "current", "4", "1", "2", "1", "0", "", "", "2", "3", "1", "21", "27.9", "", "", "88.8", "81.0", "", "59.2", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "89.5", "97.4", "", "", "", "", "95.9"]} -{"pcdb_id": 15490, "brand_name": "Eurocal", "model_name": "Ambassador", "model_qualifier": "21/27 Kitchen", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 59.2, "output_kw_max": 27.9, "final_year_of_manufacture": null, "raw": ["015490", "000218", "0", "2012/Mar/27 10:12", "Turkington Engineering", "Eurocal", "Ambassador", "21/27 Kitchen", "", "2007", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "21", "27.9", "", "", "88.8", "81.0", "", "59.2", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "89.5", "97.4", "", "", "", "", "95.9"]} -{"pcdb_id": 15491, "brand_name": "Turco", "model_name": "Ambassador", "model_qualifier": "27/38 Kitchen", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 59.2, "output_kw_max": 37.8, "final_year_of_manufacture": null, "raw": ["015491", "000218", "0", "2012/Mar/27 10:12", "Turkington Engineering", "Turco", "Ambassador", "27/38 Kitchen", "", "2007", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "27", "37.8", "", "", "88.8", "81.0", "", "59.2", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.2", "97.1", "", "", "", "", "95.8"]} -{"pcdb_id": 15492, "brand_name": "Turco", "model_name": "Countryman", "model_qualifier": "27/38 Outdoor Combi", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 81.4, "comparative_hot_water_efficiency_pct": 57.2, "output_kw_max": 37.8, "final_year_of_manufacture": null, "raw": ["015492", "000218", "0", "2007/Jul/20 09:04", "Turkington Engineering", "Turco", "Countryman", "27/38 Outdoor Combi", "", "2007", "current", "4", "1", "2", "2", "0", "", "", "2", "3", "1", "27", "37.8", "", "", "88.8", "81.4", "", "57.2", "", "2", "", "", "202", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.2", "97.1", "", "", "", "", "95.8"]} -{"pcdb_id": 15493, "brand_name": "Turco", "model_name": "Senator", "model_qualifier": "27/38 Combi", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 81.4, "comparative_hot_water_efficiency_pct": 57.2, "output_kw_max": 37.8, "final_year_of_manufacture": null, "raw": ["015493", "000218", "0", "2007/Jul/20 09:06", "Turkington Engineering", "Turco", "Senator", "27/38 Combi", "", "2007", "current", "4", "1", "1", "2", "0", "", "", "2", "3", "1", "27", "37.8", "", "", "88.8", "81.4", "", "57.2", "", "2", "", "", "202", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.2", "97.1", "", "", "", "", "95.8"]} -{"pcdb_id": 15494, "brand_name": "Turco", "model_name": "Countryman", "model_qualifier": "27/38 Slimline Outdoor", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 59.2, "output_kw_max": 37.8, "final_year_of_manufacture": null, "raw": ["015494", "000218", "0", "2012/Mar/27 10:12", "Turkington Engineering", "Turco", "Countryman", "27/38 Slimline Outdoor", "", "2007", "current", "4", "1", "2", "1", "0", "", "", "2", "3", "1", "27", "37.8", "", "", "88.8", "81.0", "", "59.2", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.2", "97.1", "", "", "", "", "95.8"]} -{"pcdb_id": 15495, "brand_name": "Eurocal", "model_name": "Countryman", "model_qualifier": "27/38 Outdoor Combi", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 81.4, "comparative_hot_water_efficiency_pct": 57.2, "output_kw_max": 37.8, "final_year_of_manufacture": null, "raw": ["015495", "000218", "0", "2007/Jul/20 09:06", "Turkington Engineering", "Eurocal", "Countryman", "27/38 Outdoor Combi", "", "2007", "current", "4", "1", "2", "2", "0", "", "", "2", "3", "1", "27", "37.8", "", "", "88.8", "81.4", "", "57.2", "", "2", "", "", "202", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.2", "97.1", "", "", "", "", "95.8"]} -{"pcdb_id": 15496, "brand_name": "Eurocal", "model_name": "Senator", "model_qualifier": "27/38 Combi", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 81.4, "comparative_hot_water_efficiency_pct": 57.2, "output_kw_max": 37.8, "final_year_of_manufacture": null, "raw": ["015496", "000218", "0", "2007/Jul/20 09:06", "Turkington Engineering", "Eurocal", "Senator", "27/38 Combi", "", "2007", "current", "4", "1", "1", "2", "0", "", "", "2", "3", "1", "27", "37.8", "", "", "88.8", "81.4", "", "57.2", "", "2", "", "", "202", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.2", "97.1", "", "", "", "", "95.8"]} -{"pcdb_id": 15498, "brand_name": "Eurocal", "model_name": "Ambassador", "model_qualifier": "27/38 Kitchen", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 59.2, "output_kw_max": 37.8, "final_year_of_manufacture": null, "raw": ["015498", "000218", "0", "2012/Mar/27 10:12", "Turkington Engineering", "Eurocal", "Ambassador", "27/38 Kitchen", "", "2007", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "27", "37.8", "", "", "88.8", "81.0", "", "59.2", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.2", "97.1", "", "", "", "", "95.8"]} -{"pcdb_id": 15499, "brand_name": "Eurocal", "model_name": "Countryman", "model_qualifier": "27/38 Slimline Outdoor", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 81.4, "comparative_hot_water_efficiency_pct": 57.2, "output_kw_max": 37.8, "final_year_of_manufacture": null, "raw": ["015499", "000218", "0", "2007/Jul/20 09:08", "Turkington Engineering", "Eurocal", "Countryman", "27/38 Slimline Outdoor", "", "2007", "current", "4", "1", "2", "2", "0", "", "", "2", "3", "1", "27", "37.8", "", "", "88.8", "81.4", "", "57.2", "", "2", "", "", "202", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.2", "97.1", "", "", "", "", "95.8"]} -{"pcdb_id": 15501, "brand_name": "Vaillant", "model_name": "ecoTEC pro 24", "model_qualifier": "", "winter_efficiency_pct": 89.3, "summer_efficiency_pct": 80.7, "comparative_hot_water_efficiency_pct": 56.7, "output_kw_max": 19.0, "final_year_of_manufacture": 2019, "raw": ["015501", "000031", "0", "2019/Mar/04 10:25", "Vaillant", "Vaillant", "ecoTEC pro 24", "", "", "2007", "2019", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "19.0", "19.0", "", "", "89.3", "80.7", "", "56.7", "", "2", "1", "", "104", "1", "2", "110", "6", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "92.0", "98.8", "", "", "", "", "97.5"]} -{"pcdb_id": 15502, "brand_name": "Vaillant", "model_name": "ecoTEC pro 24", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 56.0, "output_kw_max": 19.0, "final_year_of_manufacture": 2012, "raw": ["015502", "000031", "0", "2019/Mar/04 10:26", "Vaillant", "Vaillant", "ecoTEC pro 24", "", "47- 044-36", "2007", "2012", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "19.0", "19.0", "", "", "88.3", "79.7", "", "56.0", "", "2", "", "", "104", "1", "2", "110", "6", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.0", "96.7", "", "", "", "", "95.4"]} -{"pcdb_id": 15503, "brand_name": "Maxol", "model_name": "Supacombi", "model_qualifier": "HE 24", "winter_efficiency_pct": 85.8, "summer_efficiency_pct": 77.2, "comparative_hot_water_efficiency_pct": 60.3, "output_kw_max": 24.6, "final_year_of_manufacture": null, "raw": ["015503", "000019", "0", "2007/Dec/20 13:38", "Halstead Boilers", "Maxol", "Supacombi", "HE 24", "47-260-11", "2007", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.6", "24.6", "", "", "85.8", "77.2", "", "60.3", "", "2", "", "", "104", "1", "2", "118", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "", "0005", "", "", "", "", "", "", "", "", "88.7", "90.9", "", "", "", "", "90.5"]} -{"pcdb_id": 15505, "brand_name": "Maxol", "model_name": "Supacombi", "model_qualifier": "HE 28", "winter_efficiency_pct": 85.9, "summer_efficiency_pct": 77.3, "comparative_hot_water_efficiency_pct": 60.3, "output_kw_max": 28.3, "final_year_of_manufacture": null, "raw": ["015505", "000019", "0", "2007/Dec/20 13:38", "Halstead Boilers", "Maxol", "Supacombi", "HE 28", "47-260-12", "2007", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28.3", "28.3", "", "", "85.9", "77.3", "", "60.3", "", "2", "", "", "104", "1", "2", "130", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "", "0005", "", "", "", "", "", "", "", "", "87.9", "91.5", "", "", "", "", "90.8"]} -{"pcdb_id": 15506, "brand_name": "Express", "model_name": "BC", "model_qualifier": "24 Combi", "winter_efficiency_pct": 85.8, "summer_efficiency_pct": 77.2, "comparative_hot_water_efficiency_pct": 60.3, "output_kw_max": 24.6, "final_year_of_manufacture": null, "raw": ["015506", "000019", "0", "2007/Dec/20 13:38", "Halstead Boilers", "Express", "BC", "24 Combi", "", "2007", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.6", "24.6", "", "", "85.8", "77.2", "", "60.3", "", "2", "", "", "104", "1", "2", "118", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "", "0005", "", "", "", "", "", "", "", "", "88.7", "90.9", "", "", "", "", "90.5"]} -{"pcdb_id": 15507, "brand_name": "Express", "model_name": "BC", "model_qualifier": "28 Combi", "winter_efficiency_pct": 85.9, "summer_efficiency_pct": 77.3, "comparative_hot_water_efficiency_pct": 60.3, "output_kw_max": 28.3, "final_year_of_manufacture": null, "raw": ["015507", "000019", "0", "2007/Dec/20 13:38", "Halstead Boilers", "Express", "BC", "28 Combi", "", "2007", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28.3", "28.3", "", "", "85.9", "77.3", "", "60.3", "", "2", "", "", "104", "1", "2", "130", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "", "0005", "", "", "", "", "", "", "", "", "87.9", "91.5", "", "", "", "", "90.8"]} -{"pcdb_id": 15508, "brand_name": "Gerkros", "model_name": "50 70 Oil Condensing Boiler", "model_qualifier": "Utility Model", "winter_efficiency_pct": 87.0, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 20.69, "final_year_of_manufacture": null, "raw": ["015508", "000245", "0", "2012/Mar/27 10:12", "Gerkros Boilers (Tipperary) Limited", "Gerkros", "50 70 Oil Condensing Boiler", "Utility Model", "", "2007", "obsolete", "4", "1", "2", "1", "0", "", "", "2", "3", "1", "14.65", "20.69", "", "", "87.0", "79.2", "", "57.9", "", "2", "", "", "201", "1", "1", "250", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "89.4", "93.0", "", "", "", "", "92.3"]} -{"pcdb_id": 15509, "brand_name": "Gerkros", "model_name": "70 90 Oil Condensing Boiler", "model_qualifier": "Utility Model", "winter_efficiency_pct": 87.3, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 27.06, "final_year_of_manufacture": null, "raw": ["015509", "000245", "0", "2012/Mar/27 10:12", "Gerkros Boilers (Tipperary) Limited", "Gerkros", "70 90 Oil Condensing Boiler", "Utility Model", "", "2007", "current", "4", "1", "2", "1", "0", "", "", "2", "3", "1", "20.69", "27.06", "", "", "87.3", "79.5", "", "58.1", "", "2", "", "", "201", "1", "1", "250", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "89.7", "93.5", "", "", "", "", "92.8"]} -{"pcdb_id": 15510, "brand_name": "Gerkros", "model_name": "90 120 Oil Condensing Boiler", "model_qualifier": "Utility Model", "winter_efficiency_pct": 87.1, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 35.67, "final_year_of_manufacture": null, "raw": ["015510", "000245", "0", "2012/Mar/27 10:12", "Gerkros Boilers (Tipperary) Limited", "Gerkros", "90 120 Oil Condensing Boiler", "Utility Model", "", "2007", "current", "4", "1", "2", "1", "0", "", "", "2", "3", "1", "27.06", "35.67", "", "", "87.1", "79.3", "", "57.9", "", "2", "", "", "201", "1", "1", "250", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.0", "92.8", "", "", "", "", "92.2"]} -{"pcdb_id": 15511, "brand_name": "Atlantic Boilers", "model_name": "KDB-200NHC", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 80.9, "comparative_hot_water_efficiency_pct": 56.9, "output_kw_max": 25.0, "final_year_of_manufacture": null, "raw": ["015511", "000003", "0", "2023/Apr/27 08:50", "Atlantic 2000", "Atlantic Boilers", "KDB-200NHC", "", "", "2007", "obsolete", "4", "1", "1", "2", "0", "", "", "2", "3", "2", "23.8", "25.0", "", "", "88.3", "80.9", "", "56.9", "", "2", "", "", "202", "1", "1", "143", "5", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "93.6", "94.4", "", "", "", "", "94.3"]} -{"pcdb_id": 15512, "brand_name": "Atlantic Boilers", "model_name": "KDB-350NHC", "model_qualifier": "", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 56.8, "output_kw_max": 40.7, "final_year_of_manufacture": null, "raw": ["015512", "000003", "0", "2023/Apr/27 08:50", "Atlantic 2000", "Atlantic Boilers", "KDB-350NHC", "", "", "2007", "obsolete", "4", "1", "1", "2", "0", "", "", "2", "3", "2", "37.8", "40.7", "", "", "88.2", "80.8", "", "56.8", "", "2", "", "", "202", "1", "1", "199", "5", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "93.6", "94.1", "", "", "", "", "94.0"]} -{"pcdb_id": 15514, "brand_name": "Vaillant", "model_name": "ecoTEC exclusive 838", "model_qualifier": "", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 56.0, "output_kw_max": 30.0, "final_year_of_manufacture": 2016, "raw": ["015514", "000031", "0", "2015/Sep/21 14:23", "Vaillant", "Vaillant", "ecoTEC exclusive 838", "", "47- 044-38", "2007", "2016", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "30.0", "30.0", "", "", "88.2", "79.6", "", "56.0", "", "2", "", "", "104", "1", "2", "110", "6", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0045", "", "", "", "", "", "", "", "", "90.0", "96.6", "", "", "", "", "95.3"]} -{"pcdb_id": 15515, "brand_name": "Vaillant", "model_name": "ecoTEC exclusive 838", "model_qualifier": "", "winter_efficiency_pct": 89.3, "summer_efficiency_pct": 80.7, "comparative_hot_water_efficiency_pct": 56.7, "output_kw_max": 30.0, "final_year_of_manufacture": null, "raw": ["015515", "000031", "0", "2009/Oct/28 09:40", "Vaillant", "Vaillant", "ecoTEC exclusive 838", "", "", "2007", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "30.0", "30.0", "", "", "89.3", "80.7", "", "56.7", "", "2", "1", "", "104", "1", "2", "110", "6", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "92.0", "98.7", "", "", "", "", "97.5"]} -{"pcdb_id": 15516, "brand_name": "Vaillant", "model_name": "ecoTEC exclusive 832", "model_qualifier": "", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 56.0, "output_kw_max": 27.0, "final_year_of_manufacture": 2016, "raw": ["015516", "000031", "0", "2015/Sep/21 14:23", "Vaillant", "Vaillant", "ecoTEC exclusive 832", "", "47-044-37", "2007", "2016", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "27.0", "27.0", "", "", "88.2", "79.6", "", "56.0", "", "2", "", "", "104", "1", "2", "95", "6", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0045", "", "", "", "", "", "", "", "", "90.0", "96.5", "", "", "", "", "95.3"]} -{"pcdb_id": 15517, "brand_name": "Vaillant", "model_name": "ecoTEC exclusive 832", "model_qualifier": "", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 80.6, "comparative_hot_water_efficiency_pct": 56.7, "output_kw_max": 27.0, "final_year_of_manufacture": null, "raw": ["015517", "000031", "0", "2009/Oct/28 09:39", "Vaillant", "Vaillant", "ecoTEC exclusive 832", "", "", "2007", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "27.0", "27.0", "", "", "89.2", "80.6", "", "56.7", "", "2", "1", "", "104", "1", "2", "95", "6", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "92.0", "98.6", "", "", "", "", "97.4"]} -{"pcdb_id": 15518, "brand_name": "Alpha", "model_name": "CD25X", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 55.8, "output_kw_max": 18.4, "final_year_of_manufacture": null, "raw": ["015518", "000001", "0", "2010/Sep/29 11:40", "Alpha Therm", "Alpha", "CD25X", "", "", "2007", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "18.4", "18.4", "", "", "88.0", "79.4", "", "55.8", "", "2", "", "", "104", "1", "2", "125", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "96.9", "", "", "", "", "95.2"]} -{"pcdb_id": 15519, "brand_name": "Alpha", "model_name": "CD25X", "model_qualifier": "", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.4, "comparative_hot_water_efficiency_pct": 56.6, "output_kw_max": 18.4, "final_year_of_manufacture": null, "raw": ["015519", "000001", "0", "2007/Oct/29 08:12", "Alpha Therm", "Alpha", "CD25X", "", "", "2007", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "18.4", "18.4", "", "", "89.0", "80.4", "", "56.6", "", "2", "1", "", "104", "1", "2", "125", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.9", "99.0", "", "", "", "", "97.3"]} -{"pcdb_id": 15520, "brand_name": "Alpha", "model_name": "CD28X", "model_qualifier": "", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 55.8, "output_kw_max": 24.0, "final_year_of_manufacture": null, "raw": ["015520", "000001", "0", "2010/Sep/29 11:40", "Alpha Therm", "Alpha", "CD28X", "", "", "2007", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "87.9", "79.3", "", "55.8", "", "2", "", "", "104", "1", "2", "125", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "96.7", "", "", "", "", "95.0"]} -{"pcdb_id": 15521, "brand_name": "Alpha", "model_name": "CD28X", "model_qualifier": "", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 56.5, "output_kw_max": 24.0, "final_year_of_manufacture": null, "raw": ["015521", "000001", "0", "2007/Oct/29 08:13", "Alpha Therm", "Alpha", "CD28X", "", "", "2007", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "88.9", "80.3", "", "56.5", "", "2", "1", "", "104", "1", "2", "125", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.9", "98.8", "", "", "", "", "97.1"]} -{"pcdb_id": 15522, "brand_name": "Warmflow", "model_name": "Boilerhouse", "model_qualifier": "B1", "winter_efficiency_pct": 86.6, "summer_efficiency_pct": 74.9, "comparative_hot_water_efficiency_pct": 54.7, "output_kw_max": 26.0, "final_year_of_manufacture": null, "raw": ["015522", "000063", "0", "2012/Mar/27 10:12", "Warmflow Engineering", "Warmflow", "Boilerhouse", "B1", "", "2007", "current", "4", "1", "1", "1", "0", "", "", "1", "3", "2", "15", "26", "", "", "86.6", "74.9", "", "54.7", "", "2", "", "", "201", "1", "1", "160", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.0", "88.5", "", "", "", "", "88.0"]} -{"pcdb_id": 15523, "brand_name": "Warmflow", "model_name": "Utility", "model_qualifier": "UP90", "winter_efficiency_pct": 86.6, "summer_efficiency_pct": 74.9, "comparative_hot_water_efficiency_pct": 54.7, "output_kw_max": 26.0, "final_year_of_manufacture": null, "raw": ["015523", "000063", "0", "2012/Mar/27 10:12", "Warmflow Engineering", "Warmflow", "Utility", "UP90", "", "2007", "current", "4", "1", "1", "1", "0", "", "", "1", "3", "2", "21", "26", "", "", "86.6", "74.9", "", "54.7", "", "2", "", "", "201", "1", "1", "230", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.0", "88.5", "", "", "", "", "88.0"]} -{"pcdb_id": 15524, "brand_name": "Warmflow", "model_name": "Kabin Pak", "model_qualifier": "K90", "winter_efficiency_pct": 86.6, "summer_efficiency_pct": 74.9, "comparative_hot_water_efficiency_pct": 54.7, "output_kw_max": 26.0, "final_year_of_manufacture": null, "raw": ["015524", "000063", "0", "2012/Mar/27 10:12", "Warmflow Engineering", "Warmflow", "Kabin Pak", "K90", "", "2007", "current", "4", "1", "2", "1", "0", "", "", "1", "1", "2", "21", "26", "", "", "86.6", "74.9", "", "54.7", "", "2", "", "", "201", "1", "1", "160", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.0", "88.5", "", "", "", "", "88.0"]} -{"pcdb_id": 15525, "brand_name": "Warmflow", "model_name": "Utility", "model_qualifier": "UC90", "winter_efficiency_pct": 84.7, "summer_efficiency_pct": 76.6, "comparative_hot_water_efficiency_pct": 38.7, "output_kw_max": 26.0, "final_year_of_manufacture": null, "raw": ["015525", "000063", "0", "2024/Jan/31 10:17", "Warmflow Engineering", "Warmflow", "Utility", "UC90", "", "2007", "current", "4", "1", "1", "2", "0", "", "", "1", "3", "2", "21", "26", "", "", "84.7", "76.6", "", "38.7", "", "2", "", "", "203", "1", "1", "255", "0", "1", "1", "0", "70", "0", "25", "6", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.0", "88.5", "", "", "", "", "88.0"]} -{"pcdb_id": 15527, "brand_name": "Warmflow", "model_name": "Kabin Pak", "model_qualifier": "KP90", "winter_efficiency_pct": 86.6, "summer_efficiency_pct": 74.9, "comparative_hot_water_efficiency_pct": 54.7, "output_kw_max": 26.0, "final_year_of_manufacture": null, "raw": ["015527", "000063", "0", "2012/Mar/27 10:12", "Warmflow Engineering", "Warmflow", "Kabin Pak", "KP90", "", "2007", "current", "4", "1", "2", "1", "0", "", "", "1", "1", "2", "21", "26", "", "", "86.6", "74.9", "", "54.7", "", "2", "", "", "201", "1", "1", "230", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.0", "88.5", "", "", "", "", "88.0"]} -{"pcdb_id": 15528, "brand_name": "Warmflow", "model_name": "Kabin Pak", "model_qualifier": "KC90", "winter_efficiency_pct": 84.7, "summer_efficiency_pct": 76.6, "comparative_hot_water_efficiency_pct": 38.7, "output_kw_max": 26.0, "final_year_of_manufacture": null, "raw": ["015528", "000063", "0", "2024/Jan/31 10:17", "Warmflow Engineering", "Warmflow", "Kabin Pak", "KC90", "", "2007", "current", "4", "1", "2", "2", "0", "", "", "1", "1", "2", "21", "26", "", "", "84.7", "76.6", "", "38.7", "", "2", "", "", "203", "1", "1", "255", "0", "1", "1", "0", "70", "0", "25", "6", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.0", "88.5", "", "", "", "", "88.0"]} -{"pcdb_id": 15529, "brand_name": "Warmflow", "model_name": "Utility", "model_qualifier": "UP70HE", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 21.0, "final_year_of_manufacture": null, "raw": ["015529", "000063", "0", "2018/Jan/22 14:00", "Warmflow Engineering", "Warmflow", "Utility", "UP70HE", "", "2007", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "15", "21", "", "", "87.9", "80.1", "", "58.5", "", "2", "", "", "201", "1", "1", "230", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "89.5", "95.0", "", "", "", "", "94.0"]} -{"pcdb_id": 15530, "brand_name": "Warmflow", "model_name": "Utility", "model_qualifier": "UP90HE", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 26.0, "final_year_of_manufacture": null, "raw": ["015530", "000063", "0", "2013/Mar/28 08:27", "Warmflow Engineering", "Warmflow", "Utility", "UP90HE", "", "2007", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "21", "26", "", "", "88.0", "80.2", "", "58.6", "", "2", "", "", "201", "1", "1", "230", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.8", "94.8", "", "", "", "", "94.1"]} -{"pcdb_id": 15531, "brand_name": "Warmflow", "model_name": "Kabin Pak", "model_qualifier": "KP70HE", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 21.0, "final_year_of_manufacture": null, "raw": ["015531", "000063", "0", "2013/Mar/28 08:27", "Warmflow Engineering", "Warmflow", "Kabin Pak", "KP70HE", "", "2007", "current", "4", "1", "2", "1", "0", "", "", "2", "1", "2", "15", "21", "", "", "87.9", "80.1", "", "58.5", "", "2", "", "", "201", "1", "1", "230", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "89.5", "95.0", "", "", "", "", "94.0"]} -{"pcdb_id": 15532, "brand_name": "Warmflow", "model_name": "Kabin Pak", "model_qualifier": "KP90HE", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 26.0, "final_year_of_manufacture": null, "raw": ["015532", "000063", "0", "2013/Mar/28 08:27", "Warmflow Engineering", "Warmflow", "Kabin Pak", "KP90HE", "", "2007", "current", "4", "1", "2", "1", "0", "", "", "2", "1", "2", "21", "26", "", "", "88.0", "80.2", "", "58.6", "", "2", "", "", "201", "1", "1", "230", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.8", "94.8", "", "", "", "", "94.1"]} -{"pcdb_id": 15533, "brand_name": "Warmflow", "model_name": "Utility", "model_qualifier": "UC90HE", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 81.9, "comparative_hot_water_efficiency_pct": 41.4, "output_kw_max": 26.0, "final_year_of_manufacture": null, "raw": ["015533", "000063", "0", "2024/Jan/31 10:17", "Warmflow Engineering", "Warmflow", "Utility", "UC90HE", "", "2007", "current", "4", "1", "1", "2", "0", "", "", "2", "3", "2", "21", "26", "", "", "88.0", "81.9", "", "41.4", "", "2", "", "", "203", "1", "1", "255", "0", "1", "1", "0", "70", "0", "25", "6", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.8", "94.8", "", "", "", "", "94.1"]} -{"pcdb_id": 15534, "brand_name": "Warmflow", "model_name": "Kabin Pak", "model_qualifier": "KC90HE", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 81.9, "comparative_hot_water_efficiency_pct": 41.4, "output_kw_max": 26.0, "final_year_of_manufacture": null, "raw": ["015534", "000063", "0", "2024/Jan/31 10:17", "Warmflow Engineering", "Warmflow", "Kabin Pak", "KC90HE", "", "2007", "current", "4", "1", "2", "2", "0", "", "", "2", "1", "2", "21", "26", "", "", "88.0", "81.9", "", "41.4", "", "2", "", "", "203", "1", "1", "255", "0", "1", "1", "0", "70", "0", "25", "6", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.8", "94.8", "", "", "", "", "94.1"]} -{"pcdb_id": 15535, "brand_name": "Warmflow", "model_name": "Kabin Pak", "model_qualifier": "K70HE", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 21.0, "final_year_of_manufacture": null, "raw": ["015535", "000063", "0", "2013/Mar/28 08:28", "Warmflow Engineering", "Warmflow", "Kabin Pak", "K70HE", "", "2007", "current", "4", "1", "2", "1", "0", "", "", "2", "1", "2", "15", "21", "", "", "87.9", "80.1", "", "58.5", "", "2", "", "", "201", "1", "1", "160", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "89.5", "95.0", "", "", "", "", "94.0"]} -{"pcdb_id": 15536, "brand_name": "Warmflow", "model_name": "Kabin Pak", "model_qualifier": "K90HE", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 26.0, "final_year_of_manufacture": null, "raw": ["015536", "000063", "0", "2013/Mar/28 08:28", "Warmflow Engineering", "Warmflow", "Kabin Pak", "K90HE", "", "2007", "current", "4", "1", "2", "1", "0", "", "", "2", "1", "2", "21", "26", "", "", "88.0", "80.2", "", "58.6", "", "2", "", "", "201", "1", "1", "160", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.8", "94.8", "", "", "", "", "94.1"]} -{"pcdb_id": 15537, "brand_name": "Warmflow", "model_name": "Kabin Pak", "model_qualifier": "K120HE", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 33.0, "final_year_of_manufacture": null, "raw": ["015537", "000063", "0", "2013/Mar/28 08:28", "Warmflow Engineering", "Warmflow", "Kabin Pak", "K120HE", "", "2007", "current", "4", "1", "2", "1", "0", "", "", "2", "1", "2", "26", "33", "", "", "87.9", "80.1", "", "58.5", "", "2", "", "", "201", "1", "1", "160", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.1", "94.7", "", "", "", "", "93.9"]} -{"pcdb_id": 15538, "brand_name": "Radiant", "model_name": "RH 25", "model_qualifier": "", "winter_efficiency_pct": 85.2, "summer_efficiency_pct": 76.2, "comparative_hot_water_efficiency_pct": 55.7, "output_kw_max": 25.51, "final_year_of_manufacture": null, "raw": ["015538", "000088", "0", "2012/Mar/27 10:12", "Radiant Bruciatori SpA", "Radiant", "RH 25", "", "", "2007", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "25.51", "25.51", "", "", "85.2", "76.2", "", "55.7", "", "2", "", "", "102", "1", "2", "210", "5.4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "85.8", "90.8", "", "", "", "", "89.9"]} -{"pcdb_id": 15539, "brand_name": "Radiant", "model_name": "RH 25/B", "model_qualifier": "", "winter_efficiency_pct": 85.2, "summer_efficiency_pct": 76.2, "comparative_hot_water_efficiency_pct": 55.7, "output_kw_max": 25.51, "final_year_of_manufacture": null, "raw": ["015539", "000088", "0", "2012/Mar/27 10:12", "Radiant Bruciatori SpA", "Radiant", "RH 25/B", "", "", "2007", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "25.51", "25.51", "", "", "85.2", "76.2", "", "55.7", "", "2", "", "", "102", "1", "2", "210", "5.4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "85.8", "90.8", "", "", "", "", "89.9"]} -{"pcdb_id": 15540, "brand_name": "Radiant", "model_name": "RHA 25", "model_qualifier": "", "winter_efficiency_pct": 85.2, "summer_efficiency_pct": 78.0, "comparative_hot_water_efficiency_pct": 43.6, "output_kw_max": 25.51, "final_year_of_manufacture": null, "raw": ["015540", "000088", "0", "2024/Jan/31 10:17", "Radiant Bruciatori SpA", "Radiant", "RHA 25", "", "", "2007", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "25.51", "25.51", "", "", "85.2", "78.0", "", "43.6", "", "2", "", "", "106", "1", "2", "210", "5.4", "2", "2", "0", "20", "0", "13", "2", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "85.8", "90.8", "", "", "", "", "89.9"]} -{"pcdb_id": 15541, "brand_name": "Radiant", "model_name": "RHA 25/100", "model_qualifier": "", "winter_efficiency_pct": 85.2, "summer_efficiency_pct": 78.5, "comparative_hot_water_efficiency_pct": 35.4, "output_kw_max": 25.51, "final_year_of_manufacture": null, "raw": ["015541", "000088", "0", "2024/Jan/31 10:17", "Radiant Bruciatori SpA", "Radiant", "RHA 25/100", "", "", "2007", "current", "1", "1", "1", "2", "0", "", "", "2", "2", "2", "25.51", "25.51", "", "", "85.2", "78.5", "", "35.4", "", "2", "", "", "106", "1", "2", "210", "5.4", "2", "2", "0", "105", "0", "15", "2", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "85.8", "90.8", "", "", "", "", "89.9"]} -{"pcdb_id": 15542, "brand_name": "Radiant", "model_name": "RKR 34", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 56.0, "output_kw_max": 33.42, "final_year_of_manufacture": null, "raw": ["015542", "000088", "0", "2007/Aug/28 15:20", "Radiant Bruciatori SpA", "Radiant", "RKR 34", "", "", "2007", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "33.42", "33.42", "", "", "88.3", "79.7", "", "56.0", "", "2", "", "", "104", "1", "2", "180", "5.4", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.6", "97.2", "", "", "", "", "95.6"]} -{"pcdb_id": 15543, "brand_name": "Radiant", "model_name": "RKA 34/100", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 81.5, "comparative_hot_water_efficiency_pct": 36.8, "output_kw_max": 33.42, "final_year_of_manufacture": null, "raw": ["015543", "000088", "0", "2024/Jan/31 10:17", "Radiant Bruciatori SpA", "Radiant", "RKA 34/100", "", "", "2007", "current", "1", "1", "1", "2", "0", "", "", "2", "2", "2", "33.42", "33.42", "", "", "88.3", "81.5", "", "36.8", "", "2", "", "", "106", "1", "2", "180", "5.4", "2", "2", "0", "105", "0", "15", "2", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.6", "97.2", "", "", "", "", "95.6"]} -{"pcdb_id": 15544, "brand_name": "Radiant", "model_name": "RKA 34", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 81.1, "comparative_hot_water_efficiency_pct": 46.6, "output_kw_max": 33.42, "final_year_of_manufacture": null, "raw": ["015544", "000088", "0", "2024/Jan/31 10:17", "Radiant Bruciatori SpA", "Radiant", "RKA 34", "", "", "2007", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "33.42", "33.42", "", "", "88.3", "81.1", "", "46.6", "", "2", "", "", "106", "1", "2", "180", "5.4", "2", "2", "0", "20", "0", "15", "2", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.6", "97.2", "", "", "", "", "95.6"]} -{"pcdb_id": 15545, "brand_name": "Radiant", "model_name": "RK 34/B", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 33.42, "final_year_of_manufacture": null, "raw": ["015545", "000088", "0", "2012/Mar/27 10:12", "Radiant Bruciatori SpA", "Radiant", "RK 34/B", "", "", "2007", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "33.42", "33.42", "", "", "88.3", "79.3", "", "57.9", "", "2", "", "", "102", "1", "2", "180", "5.4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.6", "97.2", "", "", "", "", "95.6"]} -{"pcdb_id": 15546, "brand_name": "Radiant", "model_name": "RK 34", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 33.42, "final_year_of_manufacture": null, "raw": ["015546", "000088", "0", "2012/Mar/27 10:12", "Radiant Bruciatori SpA", "Radiant", "RK 34", "", "", "2007", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "33.42", "33.42", "", "", "88.3", "79.3", "", "57.9", "", "2", "", "", "102", "1", "2", "180", "5.4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.6", "97.2", "", "", "", "", "95.6"]} -{"pcdb_id": 15547, "brand_name": "Radiant", "model_name": "RKA 29/100", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 81.4, "comparative_hot_water_efficiency_pct": 36.7, "output_kw_max": 29.43, "final_year_of_manufacture": null, "raw": ["015547", "000088", "0", "2024/Jan/31 10:17", "Radiant Bruciatori SpA", "Radiant", "RKA 29/100", "", "", "2007", "current", "1", "1", "1", "2", "0", "", "", "2", "2", "2", "29.43", "29.43", "", "", "88.1", "81.4", "", "36.7", "", "2", "", "", "106", "1", "2", "180", "5.4", "2", "2", "0", "105", "0", "15", "2", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.4", "96.9", "", "", "", "", "95.3"]} -{"pcdb_id": 15548, "brand_name": "Radiant", "model_name": "RKA 29", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 80.9, "comparative_hot_water_efficiency_pct": 46.6, "output_kw_max": 29.43, "final_year_of_manufacture": null, "raw": ["015548", "000088", "0", "2024/Jan/31 10:17", "Radiant Bruciatori SpA", "Radiant", "RKA 29", "", "", "2007", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "29.43", "29.43", "", "", "88.1", "80.9", "", "46.6", "", "2", "", "", "106", "1", "2", "180", "5.4", "2", "2", "0", "20", "0", "15", "2", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.4", "96.9", "", "", "", "", "95.3"]} -{"pcdb_id": 15549, "brand_name": "Radiant", "model_name": "RK 29/B", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 29.43, "final_year_of_manufacture": null, "raw": ["015549", "000088", "0", "2012/Mar/27 10:12", "Radiant Bruciatori SpA", "Radiant", "RK 29/B", "", "", "2007", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "29.43", "29.43", "", "", "88.1", "79.1", "", "57.8", "", "2", "", "", "102", "1", "2", "180", "5.4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.4", "96.9", "", "", "", "", "95.3"]} -{"pcdb_id": 15550, "brand_name": "Radiant", "model_name": "RK 29", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 29.43, "final_year_of_manufacture": null, "raw": ["015550", "000088", "0", "2012/Mar/27 10:12", "Radiant Bruciatori SpA", "Radiant", "RK 29", "", "", "2007", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "29.43", "29.43", "", "", "88.1", "79.1", "", "57.8", "", "2", "", "", "102", "1", "2", "180", "5.4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.4", "96.9", "", "", "", "", "95.3"]} -{"pcdb_id": 15551, "brand_name": "Radiant", "model_name": "RHR 34", "model_qualifier": "", "winter_efficiency_pct": 84.9, "summer_efficiency_pct": 76.3, "comparative_hot_water_efficiency_pct": 53.7, "output_kw_max": 32.5, "final_year_of_manufacture": null, "raw": ["015551", "000088", "0", "2007/Aug/28 15:24", "Radiant Bruciatori SpA", "Radiant", "RHR 34", "", "", "2007", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "32.50", "32.50", "", "", "84.9", "76.3", "", "53.7", "", "2", "", "", "104", "1", "2", "175", "5.4", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.4", "89.2", "", "", "", "", "88.9"]} -{"pcdb_id": 15552, "brand_name": "Radiant", "model_name": "RHA 34/100", "model_qualifier": "", "winter_efficiency_pct": 84.9, "summer_efficiency_pct": 78.2, "comparative_hot_water_efficiency_pct": 35.3, "output_kw_max": 32.5, "final_year_of_manufacture": null, "raw": ["015552", "000088", "0", "2024/Jan/31 10:17", "Radiant Bruciatori SpA", "Radiant", "RHA 34/100", "", "", "2007", "current", "1", "1", "1", "2", "0", "", "", "2", "2", "2", "32.50", "32.50", "", "", "84.9", "78.2", "", "35.3", "", "2", "", "", "106", "1", "2", "175", "5.4", "2", "2", "0", "105", "0", "15", "2", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.4", "89.2", "", "", "", "", "88.9"]} -{"pcdb_id": 15553, "brand_name": "Radiant", "model_name": "RHA 34", "model_qualifier": "", "winter_efficiency_pct": 84.9, "summer_efficiency_pct": 77.7, "comparative_hot_water_efficiency_pct": 44.7, "output_kw_max": 32.5, "final_year_of_manufacture": null, "raw": ["015553", "000088", "0", "2024/Jan/31 10:17", "Radiant Bruciatori SpA", "Radiant", "RHA 34", "", "", "2007", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "32.50", "32.50", "", "", "84.9", "77.7", "", "44.7", "", "2", "", "", "106", "1", "2", "175", "5.4", "2", "2", "0", "20", "0", "15", "2", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.4", "89.2", "", "", "", "", "88.9"]} -{"pcdb_id": 15554, "brand_name": "Radiant", "model_name": "RH 34/B", "model_qualifier": "", "winter_efficiency_pct": 84.9, "summer_efficiency_pct": 75.9, "comparative_hot_water_efficiency_pct": 55.5, "output_kw_max": 32.5, "final_year_of_manufacture": null, "raw": ["015554", "000088", "0", "2012/Mar/27 10:12", "Radiant Bruciatori SpA", "Radiant", "RH 34/B", "", "", "2007", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "32.50", "32.50", "", "", "84.9", "75.9", "", "55.5", "", "2", "", "", "102", "1", "2", "175", "5.4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.4", "89.2", "", "", "", "", "88.9"]} -{"pcdb_id": 15555, "brand_name": "Radiant", "model_name": "RH 34", "model_qualifier": "", "winter_efficiency_pct": 84.9, "summer_efficiency_pct": 75.9, "comparative_hot_water_efficiency_pct": 55.5, "output_kw_max": 32.5, "final_year_of_manufacture": null, "raw": ["015555", "000088", "0", "2012/Mar/27 10:12", "Radiant Bruciatori SpA", "Radiant", "RH 34", "", "", "2007", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "32.50", "32.50", "", "", "84.9", "75.9", "", "55.5", "", "2", "", "", "102", "1", "2", "175", "5.4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.4", "89.2", "", "", "", "", "88.9"]} -{"pcdb_id": 15556, "brand_name": "Radiant", "model_name": "RHA 29/100", "model_qualifier": "", "winter_efficiency_pct": 84.9, "summer_efficiency_pct": 78.2, "comparative_hot_water_efficiency_pct": 35.3, "output_kw_max": 29.01, "final_year_of_manufacture": null, "raw": ["015556", "000088", "0", "2024/Jan/31 10:17", "Radiant Bruciatori SpA", "Radiant", "RHA 29/100", "", "", "2007", "current", "1", "1", "1", "2", "0", "", "", "2", "2", "2", "29.01", "29.01", "", "", "84.9", "78.2", "", "35.3", "", "2", "", "", "106", "1", "2", "175", "5.4", "2", "2", "0", "105", "0", "15", "2", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.1", "89.3", "", "", "", "", "88.9"]} -{"pcdb_id": 15557, "brand_name": "Radiant", "model_name": "RHA 29", "model_qualifier": "", "winter_efficiency_pct": 84.9, "summer_efficiency_pct": 77.7, "comparative_hot_water_efficiency_pct": 44.7, "output_kw_max": 29.01, "final_year_of_manufacture": null, "raw": ["015557", "000088", "0", "2024/Jan/31 10:17", "Radiant Bruciatori SpA", "Radiant", "RHA 29", "", "", "2007", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "29.01", "29.01", "", "", "84.9", "77.7", "", "44.7", "", "2", "", "", "106", "1", "2", "175", "5.4", "2", "2", "0", "20", "0", "15", "2", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.1", "89.3", "", "", "", "", "88.9"]} -{"pcdb_id": 15558, "brand_name": "Radiant", "model_name": "RH 29/B", "model_qualifier": "", "winter_efficiency_pct": 84.9, "summer_efficiency_pct": 75.9, "comparative_hot_water_efficiency_pct": 55.4, "output_kw_max": 29.01, "final_year_of_manufacture": null, "raw": ["015558", "000088", "0", "2012/Mar/27 10:12", "Radiant Bruciatori SpA", "Radiant", "RH 29/B", "", "", "2007", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "29.01", "29.01", "", "", "84.9", "75.9", "", "55.4", "", "2", "", "", "102", "1", "2", "175", "5.4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.1", "89.3", "", "", "", "", "88.9"]} -{"pcdb_id": 15559, "brand_name": "Radiant", "model_name": "RH 29", "model_qualifier": "", "winter_efficiency_pct": 84.9, "summer_efficiency_pct": 75.9, "comparative_hot_water_efficiency_pct": 55.4, "output_kw_max": 29.01, "final_year_of_manufacture": null, "raw": ["015559", "000088", "0", "2012/Mar/27 10:12", "Radiant Bruciatori SpA", "Radiant", "RH 29", "", "", "2007", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "29.01", "29.01", "", "", "84.9", "75.9", "", "55.4", "", "2", "", "", "102", "1", "2", "175", "5.4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.1", "89.3", "", "", "", "", "88.9"]} -{"pcdb_id": 15560, "brand_name": "Radiant", "model_name": "RKR 29", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 55.9, "output_kw_max": 29.43, "final_year_of_manufacture": null, "raw": ["015560", "000088", "0", "2007/Sep/14 10:41", "Radiant Bruciatori SpA", "Radiant", "RKR 29", "", "", "2007", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "29.43", "29.43", "", "", "88.1", "79.5", "", "55.9", "", "2", "", "", "104", "1", "2", "180", "5.4", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.4", "96.9", "", "", "", "", "95.3"]} -{"pcdb_id": 15562, "brand_name": "Radiant", "model_name": "RHR 29", "model_qualifier": "", "winter_efficiency_pct": 84.9, "summer_efficiency_pct": 76.3, "comparative_hot_water_efficiency_pct": 53.7, "output_kw_max": 29.01, "final_year_of_manufacture": null, "raw": ["015562", "000088", "0", "2007/Sep/14 10:42", "Radiant Bruciatori SpA", "Radiant", "RHR 29", "", "", "2007", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "29.01", "29.01", "", "", "84.9", "76.3", "", "53.7", "", "2", "", "", "104", "1", "2", "175", "5.4", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.1", "89.3", "", "", "", "", "88.9"]} -{"pcdb_id": 15563, "brand_name": "Radiant", "model_name": "RHR 25", "model_qualifier": "", "winter_efficiency_pct": 85.2, "summer_efficiency_pct": 76.6, "comparative_hot_water_efficiency_pct": 53.9, "output_kw_max": 25.51, "final_year_of_manufacture": null, "raw": ["015563", "000088", "0", "2007/Aug/28 15:28", "Radiant Bruciatori SpA", "Radiant", "RHR 25", "", "", "2007", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "25.51", "25.51", "", "", "85.2", "76.6", "", "53.9", "", "2", "", "", "104", "1", "2", "210", "5.4", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "85.8", "90.8", "", "", "", "", "89.9"]} -{"pcdb_id": 15564, "brand_name": "Radiant", "model_name": "RKA 25/100", "model_qualifier": "", "winter_efficiency_pct": 87.7, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 36.5, "output_kw_max": 24.6, "final_year_of_manufacture": null, "raw": ["015564", "000088", "0", "2024/Jan/31 10:17", "Radiant Bruciatori SpA", "Radiant", "RKA 25/100", "", "", "2007", "current", "1", "1", "1", "2", "0", "", "", "2", "2", "2", "24.60", "24.60", "", "", "87.7", "81.0", "", "36.5", "", "2", "", "", "106", "1", "2", "170", "5.4", "2", "2", "0", "105", "0", "15", "2", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.7", "95.8", "", "", "", "", "94.4"]} -{"pcdb_id": 15565, "brand_name": "Gerkros", "model_name": "50 70 Oil Condensing Boiler", "model_qualifier": "Cosyman", "winter_efficiency_pct": 87.0, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 20.69, "final_year_of_manufacture": null, "raw": ["015565", "000245", "0", "2012/Mar/27 10:12", "Gerkros Boilers (Tipperary) Limited", "Gerkros", "50 70 Oil Condensing Boiler", "Cosyman", "", "2007", "current", "4", "1", "2", "1", "0", "", "", "2", "3", "1", "14.65", "20.69", "", "", "87.0", "79.2", "", "57.9", "", "2", "", "", "201", "1", "1", "250", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "89.4", "93.0", "", "", "", "", "92.3"]} -{"pcdb_id": 15567, "brand_name": "Gerkros", "model_name": "50 70 Oil Condensing Boiler", "model_qualifier": "Boiler House Model", "winter_efficiency_pct": 87.0, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 20.69, "final_year_of_manufacture": null, "raw": ["015567", "000245", "0", "2012/Mar/27 10:12", "Gerkros Boilers (Tipperary) Limited", "Gerkros", "50 70 Oil Condensing Boiler", "Boiler House Model", "", "2007", "current", "4", "1", "2", "1", "0", "", "", "2", "3", "1", "14.65", "20.69", "", "", "87.0", "79.2", "", "57.9", "", "2", "", "", "201", "1", "1", "250", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "89.4", "93.0", "", "", "", "", "92.3"]} -{"pcdb_id": 15569, "brand_name": "Gerkros", "model_name": "70 90 Oil Condensing Boiler", "model_qualifier": "Cosyman", "winter_efficiency_pct": 87.3, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 27.06, "final_year_of_manufacture": null, "raw": ["015569", "000245", "0", "2012/Mar/27 10:12", "Gerkros Boilers (Tipperary) Limited", "Gerkros", "70 90 Oil Condensing Boiler", "Cosyman", "", "2007", "current", "4", "1", "2", "1", "0", "", "", "2", "3", "1", "20.69", "27.06", "", "", "87.3", "79.5", "", "58.1", "", "2", "", "", "201", "1", "1", "250", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "89.7", "93.5", "", "", "", "", "92.8"]} -{"pcdb_id": 15570, "brand_name": "Gerkros", "model_name": "70 90 Oil Condensing Boiler", "model_qualifier": "Boiler House Model", "winter_efficiency_pct": 87.3, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 27.06, "final_year_of_manufacture": null, "raw": ["015570", "000245", "0", "2012/Mar/27 10:12", "Gerkros Boilers (Tipperary) Limited", "Gerkros", "70 90 Oil Condensing Boiler", "Boiler House Model", "", "2007", "current", "4", "1", "2", "1", "0", "", "", "2", "3", "1", "20.69", "27.06", "", "", "87.3", "79.5", "", "58.1", "", "2", "", "", "201", "1", "1", "250", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "89.7", "93.5", "", "", "", "", "92.8"]} -{"pcdb_id": 15572, "brand_name": "Gerkros", "model_name": "90 120 Oil Condensing Boiler", "model_qualifier": "Cosyman", "winter_efficiency_pct": 87.1, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 35.67, "final_year_of_manufacture": null, "raw": ["015572", "000245", "0", "2012/Mar/27 10:12", "Gerkros Boilers (Tipperary) Limited", "Gerkros", "90 120 Oil Condensing Boiler", "Cosyman", "", "2007", "current", "4", "1", "2", "1", "0", "", "", "2", "3", "1", "27.06", "35.67", "", "", "87.1", "79.3", "", "57.9", "", "2", "", "", "201", "1", "1", "250", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.0", "92.8", "", "", "", "", "92.2"]} -{"pcdb_id": 15573, "brand_name": "Gerkros", "model_name": "90 120 Oil Condensing Boiler", "model_qualifier": "Boiler House Model", "winter_efficiency_pct": 87.1, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 35.67, "final_year_of_manufacture": null, "raw": ["015573", "000245", "0", "2012/Mar/27 10:12", "Gerkros Boilers (Tipperary) Limited", "Gerkros", "90 120 Oil Condensing Boiler", "Boiler House Model", "", "2007", "current", "4", "1", "2", "1", "0", "", "", "2", "3", "1", "27.06", "35.67", "", "", "87.1", "79.3", "", "57.9", "", "2", "", "", "201", "1", "1", "250", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.0", "92.8", "", "", "", "", "92.2"]} -{"pcdb_id": 15574, "brand_name": "Sabre", "model_name": "25HE Plus", "model_qualifier": "", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 55.8, "output_kw_max": 24.7, "final_year_of_manufacture": null, "raw": ["015574", "000011", "0", "2007/Aug/21 15:33", "Vokera", "Sabre", "25HE Plus", "", "47-094-92", "2007", "current", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "24.7", "24.7", "", "", "87.9", "79.3", "", "55.8", "", "2", "", "", "104", "1", "2", "174", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.0", "96.2", "", "", "", "", "94.9"]} -{"pcdb_id": 15575, "brand_name": "Sabre", "model_name": "29HE Plus", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 56.0, "output_kw_max": 28.77, "final_year_of_manufacture": null, "raw": ["015575", "000011", "0", "2007/Aug/21 15:33", "Vokera", "Sabre", "29HE Plus", "", "47-094-093", "2007", "current", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "28.77", "28.77", "", "", "88.3", "79.7", "", "56.0", "", "2", "", "", "104", "1", "2", "170", "0", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.4", "96.9", "", "", "", "", "95.4"]} -{"pcdb_id": 15576, "brand_name": "Pro", "model_name": "Pro-Combi", "model_qualifier": "120HE", "winter_efficiency_pct": 85.0, "summer_efficiency_pct": 76.4, "comparative_hot_water_efficiency_pct": 53.7, "output_kw_max": 33.93, "final_year_of_manufacture": null, "raw": ["015576", "000247", "0", "2007/Aug/21 15:30", "Vokera", "Pro", "Pro-Combi", "120HE", "47-094-94", "2007", "current", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "14.04", "33.93", "", "", "85.0", "76.4", "", "53.7", "", "2", "", "", "104", "1", "2", "153", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "89.1", "", "", "", "", "88.9"]} -{"pcdb_id": 15577, "brand_name": "Vokera", "model_name": "Mynute", "model_qualifier": "20VHE", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 19.68, "final_year_of_manufacture": null, "raw": ["015577", "000011", "0", "2012/Mar/27 10:12", "Vokera", "Vokera", "Mynute", "20VHE", "41-094-70", "2007", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "19.68", "19.68", "", "", "88.1", "79.1", "", "57.8", "", "2", "", "", "102", "1", "2", "150", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.7", "96.9", "", "", "", "", "95.3"]} -{"pcdb_id": 15578, "brand_name": "Vokera", "model_name": "Linea", "model_qualifier": "36HE", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 56.1, "output_kw_max": 33.7, "final_year_of_manufacture": null, "raw": ["015578", "000011", "0", "2007/Oct/29 08:14", "Vokera", "Vokera", "Linea", "36HE", "47-094-91", "2007", "current", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "33.70", "33.70", "", "", "88.4", "79.8", "", "56.1", "", "2", "", "", "104", "1", "2", "175", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "97.8", "", "", "", "", "95.9"]} -{"pcdb_id": 15579, "brand_name": "Vokera", "model_name": "Linea", "model_qualifier": "32HE", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 56.2, "output_kw_max": 29.4, "final_year_of_manufacture": null, "raw": ["015579", "000011", "0", "2007/Oct/29 08:14", "Vokera", "Vokera", "Linea", "32HE", "47-094-90", "2007", "current", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "29.40", "29.40", "", "", "88.6", "80.0", "", "56.2", "", "2", "", "", "104", "1", "2", "130", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.4", "98.1", "", "", "", "", "96.3"]} -{"pcdb_id": 15580, "brand_name": "Vokera", "model_name": "Linea", "model_qualifier": "28HE", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 55.8, "output_kw_max": 24.4, "final_year_of_manufacture": null, "raw": ["015580", "000011", "0", "2007/Oct/29 08:14", "Vokera", "Vokera", "Linea", "28HE", "47-094-89", "2007", "current", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "24.40", "24.40", "", "", "87.9", "79.3", "", "55.8", "", "2", "", "", "104", "1", "2", "130", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "96.5", "", "", "", "", "94.9"]} -{"pcdb_id": 15581, "brand_name": "Trianco", "model_name": "Contractor HE External", "model_qualifier": "50/90", "winter_efficiency_pct": 85.0, "summer_efficiency_pct": 77.2, "comparative_hot_water_efficiency_pct": 56.4, "output_kw_max": 26.4, "final_year_of_manufacture": null, "raw": ["015581", "000062", "0", "2012/Mar/27 10:12", "Trianco", "Trianco", "Contractor HE External", "50/90", "2375", "2006", "current", "4", "1", "2", "1", "0", "", "", "2", "3", "2", "14.6", "26.4", "", "", "85.0", "77.2", "", "56.4", "", "2", "", "", "201", "1", "1", "148", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "87.1", "90.6", "", "", "", "", "89.9"]} -{"pcdb_id": 15582, "brand_name": "Trianco", "model_name": "Contractor HE System", "model_qualifier": "50/90", "winter_efficiency_pct": 85.2, "summer_efficiency_pct": 77.4, "comparative_hot_water_efficiency_pct": 56.6, "output_kw_max": 26.4, "final_year_of_manufacture": null, "raw": ["015582", "000062", "0", "2012/Mar/27 10:12", "Trianco", "Trianco", "Contractor HE System", "50/90", "2371", "2007", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "14.6", "26.4", "", "", "85.2", "77.4", "", "56.6", "", "2", "", "", "201", "1", "1", "148", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "87.7", "90.6", "", "", "", "", "90.1"]} -{"pcdb_id": 15583, "brand_name": "Trianco", "model_name": "Contractor Trader HE", "model_qualifier": "50/90", "winter_efficiency_pct": 85.2, "summer_efficiency_pct": 77.4, "comparative_hot_water_efficiency_pct": 56.6, "output_kw_max": 26.4, "final_year_of_manufacture": null, "raw": ["015583", "000062", "0", "2012/Mar/27 10:12", "Trianco", "Trianco", "Contractor Trader HE", "50/90", "2377", "2007", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "14.6", "26.4", "", "", "85.2", "77.4", "", "56.6", "", "2", "", "", "201", "1", "1", "148", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "87.7", "90.6", "", "", "", "", "90.1"]} -{"pcdb_id": 15584, "brand_name": "Trianco", "model_name": "Contractor HE", "model_qualifier": "50/90", "winter_efficiency_pct": 85.2, "summer_efficiency_pct": 77.4, "comparative_hot_water_efficiency_pct": 56.6, "output_kw_max": 26.4, "final_year_of_manufacture": null, "raw": ["015584", "000062", "0", "2012/Mar/27 10:12", "Trianco", "Trianco", "Contractor HE", "50/90", "2370", "2007", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "14.6", "26.4", "", "", "85.2", "77.4", "", "56.6", "", "2", "", "", "201", "1", "1", "148", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "87.7", "90.6", "", "", "", "", "90.1"]} -{"pcdb_id": 15585, "brand_name": "Trianco", "model_name": "Iona", "model_qualifier": "HE 50/90", "winter_efficiency_pct": 85.2, "summer_efficiency_pct": 77.4, "comparative_hot_water_efficiency_pct": 56.6, "output_kw_max": 26.4, "final_year_of_manufacture": null, "raw": ["015585", "000062", "0", "2012/Mar/27 10:12", "Trianco", "Trianco", "Iona", "HE 50/90", "", "2007", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "14.6", "26.4", "", "", "85.2", "77.4", "", "56.6", "", "2", "", "", "201", "1", "1", "148", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "87.7", "90.6", "", "", "", "", "90.1"]} -{"pcdb_id": 15586, "brand_name": "Sime", "model_name": "Ecomfort", "model_qualifier": "System 25 HE", "winter_efficiency_pct": 86.3, "summer_efficiency_pct": 77.3, "comparative_hot_water_efficiency_pct": 56.5, "output_kw_max": 24.7, "final_year_of_manufacture": 2018, "raw": ["015586", "000213", "0", "2018/Feb/26 16:46", "Fonderie Sime S.p.A.", "Sime", "Ecomfort", "System 25 HE", "", "2007", "2018", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "24.7", "24.7", "", "", "86.3", "77.3", "", "56.5", "", "2", "", "", "102", "1", "2", "150", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.4", "92.8", "", "", "", "", "91.8"]} -{"pcdb_id": 15587, "brand_name": "Sime", "model_name": "Ecomfort", "model_qualifier": "System 25 HE", "winter_efficiency_pct": 87.3, "summer_efficiency_pct": 78.3, "comparative_hot_water_efficiency_pct": 57.2, "output_kw_max": 24.7, "final_year_of_manufacture": 2018, "raw": ["015587", "000213", "0", "2018/Feb/26 16:46", "Fonderie Sime S.p.A.", "Sime", "Ecomfort", "System 25 HE", "", "2007", "2018", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "24.7", "24.7", "", "", "87.3", "78.3", "", "57.2", "", "2", "1", "", "102", "1", "2", "150", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.3", "94.9", "", "", "", "", "93.8"]} -{"pcdb_id": 15588, "brand_name": "Sime", "model_name": "Ecomfort", "model_qualifier": "35 HE", "winter_efficiency_pct": 85.8, "summer_efficiency_pct": 77.2, "comparative_hot_water_efficiency_pct": 54.3, "output_kw_max": 33.5, "final_year_of_manufacture": 2018, "raw": ["015588", "000213", "0", "2018/Feb/26 16:41", "Fonderie Sime S.p.A.", "Sime", "Ecomfort", "35 HE", "", "2007", "2018", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "33.5", "33.5", "", "", "85.8", "77.2", "", "54.3", "", "2", "", "", "104", "1", "2", "160", "10", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.4", "91.5", "", "", "", "", "90.7"]} -{"pcdb_id": 15589, "brand_name": "Sime", "model_name": "Ecomfort", "model_qualifier": "35 HE", "winter_efficiency_pct": 86.8, "summer_efficiency_pct": 78.2, "comparative_hot_water_efficiency_pct": 55.0, "output_kw_max": 33.5, "final_year_of_manufacture": 2018, "raw": ["015589", "000213", "0", "2018/Feb/26 16:42", "Fonderie Sime S.p.A.", "Sime", "Ecomfort", "35 HE", "", "2007", "2018", "2", "2", "1", "2", "0", "", "", "2", "3", "2", "33.5", "33.5", "", "", "86.8", "78.2", "", "55.0", "", "2", "1", "", "104", "1", "2", "160", "10", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.3", "93.5", "", "", "", "", "92.7"]} -{"pcdb_id": 15590, "brand_name": "Mistral Boilers", "model_name": "CKUT7 58/68", "model_qualifier": "", "winter_efficiency_pct": 87.6, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 68.0, "final_year_of_manufacture": null, "raw": ["015590", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral Boilers", "CKUT7 58/68", "", "", "2007", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "58", "68", "", "", "87.6", "79.8", "", "58.3", "", "2", "", "", "201", "1", "1", "230", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.9", "93.8", "", "", "", "", "93.2"]} -{"pcdb_id": 15592, "brand_name": "Mistral Boilers", "model_name": "CKUT6 50/58", "model_qualifier": "", "winter_efficiency_pct": 87.6, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 58.0, "final_year_of_manufacture": null, "raw": ["015592", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral Boilers", "CKUT6 50/58", "", "", "2007", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "50", "58", "", "", "87.6", "79.8", "", "58.3", "", "2", "", "", "201", "1", "1", "230", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.9", "93.8", "", "", "", "", "93.2"]} -{"pcdb_id": 15593, "brand_name": "Mistral Boilers", "model_name": "CKUT5 41/50", "model_qualifier": "", "winter_efficiency_pct": 87.6, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 50.0, "final_year_of_manufacture": null, "raw": ["015593", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral Boilers", "CKUT5 41/50", "", "", "2007", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "41", "50", "", "", "87.6", "79.8", "", "58.3", "", "2", "", "", "201", "1", "1", "230", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.9", "93.8", "", "", "", "", "93.2"]} -{"pcdb_id": 15594, "brand_name": "Mistral Boilers", "model_name": "CMC7 58/68", "model_qualifier": "", "winter_efficiency_pct": 87.6, "summer_efficiency_pct": 81.5, "comparative_hot_water_efficiency_pct": 45.1, "output_kw_max": 68.0, "final_year_of_manufacture": null, "raw": ["015594", "000056", "0", "2024/Jan/31 10:17", "Mistral Boilers", "Mistral Boilers", "CMC7 58/68", "", "", "2007", "current", "4", "1", "1", "2", "0", "", "", "2", "3", "2", "58", "68", "", "", "87.6", "81.5", "", "45.1", "", "2", "", "", "203", "1", "1", "230", "0", "2", "", "0", "120", "0", "30", "3", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.9", "93.8", "", "", "", "", "93.2"]} -{"pcdb_id": 15595, "brand_name": "Mistral Boilers", "model_name": "CMC6 50/58", "model_qualifier": "", "winter_efficiency_pct": 87.6, "summer_efficiency_pct": 81.5, "comparative_hot_water_efficiency_pct": 45.1, "output_kw_max": 58.0, "final_year_of_manufacture": null, "raw": ["015595", "000056", "0", "2024/Jan/31 10:17", "Mistral Boilers", "Mistral Boilers", "CMC6 50/58", "", "", "2007", "current", "4", "1", "1", "2", "0", "", "", "2", "3", "2", "50", "58", "", "", "87.6", "81.5", "", "45.1", "", "2", "", "", "203", "1", "1", "230", "0", "2", "", "0", "120", "0", "30", "3", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.9", "93.8", "", "", "", "", "93.2"]} -{"pcdb_id": 15596, "brand_name": "Mistral Boilers", "model_name": "CMC5 41/50", "model_qualifier": "", "winter_efficiency_pct": 87.6, "summer_efficiency_pct": 81.5, "comparative_hot_water_efficiency_pct": 45.1, "output_kw_max": 50.0, "final_year_of_manufacture": null, "raw": ["015596", "000056", "0", "2024/Jan/31 10:17", "Mistral Boilers", "Mistral Boilers", "CMC5 41/50", "", "", "2007", "current", "4", "1", "1", "2", "0", "", "", "2", "3", "2", "41", "50", "", "", "87.6", "81.5", "", "45.1", "", "2", "", "", "203", "1", "1", "230", "0", "2", "", "0", "120", "0", "30", "3", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.9", "93.8", "", "", "", "", "93.2"]} -{"pcdb_id": 15597, "brand_name": "Mistral Boilers", "model_name": "CBH6 50/58", "model_qualifier": "", "winter_efficiency_pct": 87.6, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 58.0, "final_year_of_manufacture": null, "raw": ["015597", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral Boilers", "CBH6 50/58", "", "", "2007", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "50", "58", "", "", "87.6", "79.8", "", "58.3", "", "2", "", "", "201", "1", "1", "230", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.9", "93.8", "", "", "", "", "93.2"]} -{"pcdb_id": 15598, "brand_name": "Mistral Boilers", "model_name": "CBH7 58/68", "model_qualifier": "", "winter_efficiency_pct": 87.6, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 68.0, "final_year_of_manufacture": null, "raw": ["015598", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral Boilers", "CBH7 58/68", "", "", "2007", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "58", "68", "", "", "87.6", "79.8", "", "58.3", "", "2", "", "", "201", "1", "1", "230", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.9", "93.8", "", "", "", "", "93.2"]} -{"pcdb_id": 15599, "brand_name": "Mistral Boilers", "model_name": "CBH5 41/50", "model_qualifier": "", "winter_efficiency_pct": 87.6, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 50.0, "final_year_of_manufacture": null, "raw": ["015599", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral Boilers", "CBH5 41/50", "", "", "2007", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "41", "50", "", "", "87.6", "79.8", "", "58.3", "", "2", "", "", "201", "1", "1", "230", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.9", "93.8", "", "", "", "", "93.2"]} -{"pcdb_id": 15600, "brand_name": "Mistral Boilers", "model_name": "CODMC7 58/68", "model_qualifier": "", "winter_efficiency_pct": 87.6, "summer_efficiency_pct": 81.5, "comparative_hot_water_efficiency_pct": 45.1, "output_kw_max": 68.0, "final_year_of_manufacture": null, "raw": ["015600", "000056", "0", "2024/Jan/31 10:17", "Mistral Boilers", "Mistral Boilers", "CODMC7 58/68", "", "", "2007", "current", "4", "1", "2", "2", "0", "", "", "2", "3", "2", "58", "68", "", "", "87.6", "81.5", "", "45.1", "", "2", "", "", "203", "1", "1", "230", "0", "2", "", "0", "120", "0", "30", "3", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.9", "93.8", "", "", "", "", "93.2"]} -{"pcdb_id": 15601, "brand_name": "Mistral Boilers", "model_name": "CODMC6 50/58", "model_qualifier": "", "winter_efficiency_pct": 87.6, "summer_efficiency_pct": 81.5, "comparative_hot_water_efficiency_pct": 45.1, "output_kw_max": 58.0, "final_year_of_manufacture": null, "raw": ["015601", "000056", "0", "2024/Jan/31 10:17", "Mistral Boilers", "Mistral Boilers", "CODMC6 50/58", "", "", "2007", "current", "4", "1", "2", "2", "0", "", "", "2", "3", "2", "50", "58", "", "", "87.6", "81.5", "", "45.1", "", "2", "", "", "203", "1", "1", "230", "0", "2", "", "0", "120", "0", "30", "3", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.9", "93.8", "", "", "", "", "93.2"]} -{"pcdb_id": 15602, "brand_name": "Mistral Boilers", "model_name": "CODMC5 41/50", "model_qualifier": "", "winter_efficiency_pct": 87.6, "summer_efficiency_pct": 81.5, "comparative_hot_water_efficiency_pct": 45.1, "output_kw_max": 50.0, "final_year_of_manufacture": null, "raw": ["015602", "000056", "0", "2024/Jan/31 10:17", "Mistral Boilers", "Mistral Boilers", "CODMC5 41/50", "", "", "2007", "current", "4", "1", "2", "2", "0", "", "", "2", "3", "2", "41", "50", "", "", "87.6", "81.5", "", "45.1", "", "2", "", "", "203", "1", "1", "230", "0", "2", "", "0", "120", "0", "30", "3", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.9", "93.8", "", "", "", "", "93.2"]} -{"pcdb_id": 15603, "brand_name": "Mistral Boilers", "model_name": "COD7 SS 58/68", "model_qualifier": "", "winter_efficiency_pct": 87.6, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 68.0, "final_year_of_manufacture": null, "raw": ["015603", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral Boilers", "COD7 SS 58/68", "", "", "2007", "current", "4", "1", "2", "1", "0", "", "", "2", "3", "2", "58", "68", "", "", "87.6", "79.8", "", "58.3", "", "2", "", "", "201", "1", "1", "230", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.9", "93.8", "", "", "", "", "93.2"]} -{"pcdb_id": 15604, "brand_name": "Mistral Boilers", "model_name": "COD6 SS 50/58", "model_qualifier": "", "winter_efficiency_pct": 87.6, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 58.0, "final_year_of_manufacture": null, "raw": ["015604", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral Boilers", "COD6 SS 50/58", "", "", "2007", "current", "4", "1", "2", "1", "0", "", "", "2", "3", "2", "50", "58", "", "", "87.6", "79.8", "", "58.3", "", "2", "", "", "201", "1", "1", "230", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.9", "93.8", "", "", "", "", "93.2"]} -{"pcdb_id": 15605, "brand_name": "Mistral Boilers", "model_name": "COD5 SS 41/50", "model_qualifier": "", "winter_efficiency_pct": 87.6, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 50.0, "final_year_of_manufacture": null, "raw": ["015605", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral Boilers", "COD5 SS 41/50", "", "", "2007", "current", "4", "1", "2", "1", "0", "", "", "2", "3", "2", "41", "50", "", "", "87.6", "79.8", "", "58.3", "", "2", "", "", "201", "1", "1", "230", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.9", "93.8", "", "", "", "", "93.2"]} -{"pcdb_id": 15606, "brand_name": "Mistral Boilers", "model_name": "CS6 50/58", "model_qualifier": "", "winter_efficiency_pct": 87.6, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 58.0, "final_year_of_manufacture": null, "raw": ["015606", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral Boilers", "CS6 50/58", "", "", "2007", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "50", "58", "", "", "87.6", "79.8", "", "58.3", "", "2", "", "", "201", "1", "1", "230", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.9", "93.8", "", "", "", "", "93.2"]} -{"pcdb_id": 15607, "brand_name": "Mistral Boilers", "model_name": "CS5 41/50", "model_qualifier": "", "winter_efficiency_pct": 87.6, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 50.0, "final_year_of_manufacture": null, "raw": ["015607", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral Boilers", "CS5 41/50", "", "", "2007", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "41", "50", "", "", "87.6", "79.8", "", "58.3", "", "2", "", "", "201", "1", "1", "230", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.9", "93.8", "", "", "", "", "93.2"]} -{"pcdb_id": 15608, "brand_name": "Mistral Boilers", "model_name": "CS7 58/68", "model_qualifier": "", "winter_efficiency_pct": 87.6, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 68.0, "final_year_of_manufacture": null, "raw": ["015608", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral Boilers", "CS7 58/68", "", "", "2007", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "58", "68", "", "", "87.6", "79.8", "", "58.3", "", "2", "", "", "201", "1", "1", "230", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.9", "93.8", "", "", "", "", "93.2"]} -{"pcdb_id": 15609, "brand_name": "Mistral Boilers", "model_name": "COD5 41/50", "model_qualifier": "", "winter_efficiency_pct": 87.6, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 50.0, "final_year_of_manufacture": null, "raw": ["015609", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral Boilers", "COD5 41/50", "", "", "2007", "current", "4", "1", "2", "1", "0", "", "", "2", "3", "2", "41", "50", "", "", "87.6", "79.8", "", "58.3", "", "2", "", "", "201", "1", "1", "230", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.9", "93.8", "", "", "", "", "93.2"]} -{"pcdb_id": 15610, "brand_name": "Mistral Boilers", "model_name": "COD6 50/58", "model_qualifier": "", "winter_efficiency_pct": 87.6, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 58.0, "final_year_of_manufacture": null, "raw": ["015610", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral Boilers", "COD6 50/58", "", "", "2007", "current", "4", "1", "2", "1", "0", "", "", "2", "3", "2", "50", "58", "", "", "87.6", "79.8", "", "58.3", "", "2", "", "", "201", "1", "1", "230", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.9", "93.8", "", "", "", "", "93.2"]} -{"pcdb_id": 15611, "brand_name": "Mistral Boilers", "model_name": "COD7 58/68", "model_qualifier": "", "winter_efficiency_pct": 87.6, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 68.0, "final_year_of_manufacture": null, "raw": ["015611", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral Boilers", "COD7 58/68", "", "", "2007", "current", "4", "1", "2", "1", "0", "", "", "2", "3", "2", "58", "68", "", "", "87.6", "79.8", "", "58.3", "", "2", "", "", "201", "1", "1", "230", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.9", "93.8", "", "", "", "", "93.2"]} -{"pcdb_id": 15612, "brand_name": "Alpha", "model_name": "CD20S", "model_qualifier": "", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 18.0, "final_year_of_manufacture": null, "raw": ["015612", "000001", "0", "2012/Mar/27 10:12", "Alpha Therm", "Alpha", "CD20S", "", "", "2007", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "18", "18", "", "", "89.1", "80.1", "", "58.5", "", "2", "1", "", "102", "1", "2", "135", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.8", "99.3", "", "", "", "", "97.5"]} -{"pcdb_id": 15613, "brand_name": "Alpha", "model_name": "CD20S", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 18.0, "final_year_of_manufacture": null, "raw": ["015613", "000001", "0", "2012/Mar/27 10:12", "Alpha Therm", "Alpha", "CD20S", "", "", "2007", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18", "18", "", "", "88.1", "79.1", "", "57.8", "", "2", "", "", "102", "1", "2", "135", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "97.1", "", "", "", "", "95.4"]} -{"pcdb_id": 15614, "brand_name": "Alpha", "model_name": "CD28S", "model_qualifier": "", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 28.0, "final_year_of_manufacture": null, "raw": ["015614", "000001", "0", "2012/Mar/27 10:12", "Alpha Therm", "Alpha", "CD28S", "", "", "2007", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "28", "28", "", "", "89.1", "80.1", "", "58.5", "", "2", "1", "", "102", "1", "2", "125", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.8", "99.4", "", "", "", "", "97.6"]} -{"pcdb_id": 15615, "brand_name": "Alpha", "model_name": "CD28S", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 28.0, "final_year_of_manufacture": null, "raw": ["015615", "000001", "0", "2012/Mar/27 10:12", "Alpha Therm", "Alpha", "CD28S", "", "", "2007", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "28", "28", "", "", "88.1", "79.1", "", "57.8", "", "2", "", "", "102", "1", "2", "125", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "97.2", "", "", "", "", "95.4"]} -{"pcdb_id": 15616, "brand_name": "Alpha", "model_name": "CD12S", "model_qualifier": "", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 12.0, "final_year_of_manufacture": null, "raw": ["015616", "000001", "0", "2012/Mar/27 10:12", "Alpha Therm", "Alpha", "CD12S", "", "", "2007", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "12", "12", "", "", "88.9", "79.9", "", "58.3", "", "2", "1", "", "102", "1", "2", "120", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.8", "98.6", "", "", "", "", "97.0"]} -{"pcdb_id": 15617, "brand_name": "Alpha", "model_name": "CD12S", "model_qualifier": "", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 78.9, "comparative_hot_water_efficiency_pct": 57.6, "output_kw_max": 12.0, "final_year_of_manufacture": null, "raw": ["015617", "000001", "0", "2012/Mar/27 10:12", "Alpha Therm", "Alpha", "CD12S", "", "", "2007", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "12", "12", "", "", "87.9", "78.9", "", "57.6", "", "2", "", "", "102", "1", "2", "120", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "96.5", "", "", "", "", "94.9"]} -{"pcdb_id": 15620, "brand_name": "Trianco", "model_name": "Contractor Utility", "model_qualifier": "100/125", "winter_efficiency_pct": 85.7, "summer_efficiency_pct": 74.0, "comparative_hot_water_efficiency_pct": 54.0, "output_kw_max": 36.4, "final_year_of_manufacture": null, "raw": ["015620", "000062", "0", "2012/Mar/27 10:12", "Trianco Heating Products", "Trianco", "Contractor Utility", "100/125", "2301", "2007", "current", "4", "1", "1", "1", "0", "", "", "1", "3", "2", "29.3", "36.4", "", "", "85.7", "74.0", "", "54.0", "", "2", "", "", "201", "1", "1", "148", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.4", "86.0", "", "", "", "", "85.9"]} -{"pcdb_id": 15621, "brand_name": "Trianco", "model_name": "Contractor 100/125 External", "model_qualifier": "", "winter_efficiency_pct": 85.7, "summer_efficiency_pct": 74.0, "comparative_hot_water_efficiency_pct": 54.0, "output_kw_max": 36.4, "final_year_of_manufacture": 2008, "raw": ["015621", "000062", "0", "2012/Mar/27 10:12", "Trianco Heating Products", "Trianco", "Contractor 100/125 External", "", "2311", "2007", "2008", "4", "1", "1", "1", "0", "", "", "1", "3", "2", "29.3", "36.4", "", "", "85.7", "74.0", "", "54.0", "", "2", "", "", "201", "1", "1", "148", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.4", "86.0", "", "", "", "", "85.9"]} -{"pcdb_id": 15622, "brand_name": "Trianco", "model_name": "Iona External 100/125 HE", "model_qualifier": "", "winter_efficiency_pct": 84.6, "summer_efficiency_pct": 76.8, "comparative_hot_water_efficiency_pct": 56.1, "output_kw_max": 36.4, "final_year_of_manufacture": null, "raw": ["015622", "000062", "0", "2012/Mar/27 10:12", "Trianco Heating Products", "Trianco", "Iona External 100/125 HE", "", "2396", "2007", "current", "4", "1", "2", "1", "0", "", "", "2", "3", "2", "30", "36.4", "", "", "84.6", "76.8", "", "56.1", "", "2", "", "", "201", "1", "1", "148", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "87.8", "89.1", "", "", "", "", "88.9"]} -{"pcdb_id": 15623, "brand_name": "Trianco", "model_name": "Iona 100/125 HE", "model_qualifier": "", "winter_efficiency_pct": 84.6, "summer_efficiency_pct": 76.8, "comparative_hot_water_efficiency_pct": 56.1, "output_kw_max": 36.4, "final_year_of_manufacture": null, "raw": ["015623", "000062", "0", "2012/Mar/27 10:12", "Trianco Heating Products", "Trianco", "Iona 100/125 HE", "", "2392", "2007", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "30", "36.4", "", "", "84.6", "76.8", "", "56.1", "", "2", "", "", "201", "1", "1", "148", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "87.8", "89.1", "", "", "", "", "88.9"]} -{"pcdb_id": 15624, "brand_name": "Trianco", "model_name": "Contractor 100/125 External HE", "model_qualifier": "", "winter_efficiency_pct": 84.6, "summer_efficiency_pct": 76.8, "comparative_hot_water_efficiency_pct": 56.1, "output_kw_max": 36.4, "final_year_of_manufacture": null, "raw": ["015624", "000062", "0", "2012/Mar/27 10:12", "Trianco Heating Products", "Trianco", "Contractor 100/125 External HE", "", "2376", "2007", "current", "4", "1", "2", "1", "0", "", "", "2", "3", "2", "30", "36.4", "", "", "84.6", "76.8", "", "56.1", "", "2", "", "", "201", "1", "1", "148", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "87.8", "89.1", "", "", "", "", "88.9"]} -{"pcdb_id": 15625, "brand_name": "Trianco", "model_name": "Contractor Utility HE", "model_qualifier": "100/125", "winter_efficiency_pct": 84.8, "summer_efficiency_pct": 77.0, "comparative_hot_water_efficiency_pct": 56.3, "output_kw_max": 38.0, "final_year_of_manufacture": null, "raw": ["015625", "000062", "0", "2012/Mar/27 10:12", "Trianco Heating Products", "Trianco", "Contractor Utility HE", "100/125", "2372", "2007", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "30", "38", "", "", "84.8", "77.0", "", "56.3", "", "2", "", "", "201", "1", "1", "148", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "87.8", "89.7", "", "", "", "", "89.3"]} -{"pcdb_id": 15626, "brand_name": "Trianco", "model_name": "Contractor Utility", "model_qualifier": "130/180", "winter_efficiency_pct": 86.5, "summer_efficiency_pct": 74.8, "comparative_hot_water_efficiency_pct": 54.7, "output_kw_max": 53.0, "final_year_of_manufacture": 2007, "raw": ["015626", "000062", "0", "2012/Mar/27 10:12", "Trianco Heating Products", "Trianco", "Contractor Utility", "130/180", "2296E", "2007", "2007", "4", "1", "1", "1", "0", "", "", "1", "3", "2", "38", "53", "", "", "86.5", "74.8", "", "54.7", "", "2", "", "", "201", "1", "1", "148", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.0", "86.9", "", "", "", "", "86.9"]} -{"pcdb_id": 15627, "brand_name": "Trianco", "model_name": "Iona HE", "model_qualifier": "130/180", "winter_efficiency_pct": 85.5, "summer_efficiency_pct": 77.7, "comparative_hot_water_efficiency_pct": 56.8, "output_kw_max": 52.8, "final_year_of_manufacture": null, "raw": ["015627", "000062", "0", "2012/Mar/27 10:12", "Trianco Heating Products", "Trianco", "Iona HE", "130/180", "2393", "2007", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "41.4", "52.8", "", "", "85.5", "77.7", "", "56.8", "", "2", "", "", "201", "1", "1", "148", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "88.8", "90.0", "", "", "", "", "89.8"]} -{"pcdb_id": 15628, "brand_name": "Trianco", "model_name": "Contractor Utility HE", "model_qualifier": "130/180", "winter_efficiency_pct": 85.5, "summer_efficiency_pct": 77.7, "comparative_hot_water_efficiency_pct": 56.8, "output_kw_max": 53.0, "final_year_of_manufacture": null, "raw": ["015628", "000062", "0", "2012/Mar/27 10:12", "Trianco Heating Products", "Trianco", "Contractor Utility HE", "130/180", "2373", "2007", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "41.4", "53.0", "", "", "85.5", "77.7", "", "56.8", "", "2", "", "", "201", "1", "1", "148", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "88.8", "90.0", "", "", "", "", "89.8"]} -{"pcdb_id": 15629, "brand_name": "Trianco", "model_name": "Contractor Utility", "model_qualifier": "190/220", "winter_efficiency_pct": 86.3, "summer_efficiency_pct": 74.6, "comparative_hot_water_efficiency_pct": 54.5, "output_kw_max": 64.0, "final_year_of_manufacture": 2007, "raw": ["015629", "000062", "0", "2012/Mar/27 10:12", "Trianco Heating Products", "Trianco", "Contractor Utility", "190/220", "2298E", "2007", "2007", "4", "1", "1", "1", "0", "", "", "1", "3", "2", "55.7", "64", "", "", "86.3", "74.6", "", "54.5", "", "2", "", "", "201", "1", "1", "148", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.5", "87.2", "", "", "", "", "86.9"]} -{"pcdb_id": 15630, "brand_name": "Trianco", "model_name": "Iona HE", "model_qualifier": "190/220", "winter_efficiency_pct": 84.5, "summer_efficiency_pct": 76.7, "comparative_hot_water_efficiency_pct": 56.0, "output_kw_max": 64.6, "final_year_of_manufacture": null, "raw": ["015630", "000062", "0", "2012/Mar/27 10:12", "Trianco Heating Products", "Trianco", "Iona HE", "190/220", "2394", "2007", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "56.5", "64.6", "", "", "84.5", "76.7", "", "56.0", "", "2", "", "", "201", "1", "1", "148", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "88.0", "88.8", "", "", "", "", "88.7"]} -{"pcdb_id": 15631, "brand_name": "Trianco", "model_name": "Contractor Utility HE", "model_qualifier": "190/220", "winter_efficiency_pct": 84.5, "summer_efficiency_pct": 76.7, "comparative_hot_water_efficiency_pct": 56.0, "output_kw_max": 65.0, "final_year_of_manufacture": null, "raw": ["015631", "000062", "0", "2012/Mar/27 10:12", "Trianco Heating Products", "Trianco", "Contractor Utility HE", "190/220", "2374", "2007", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "56.5", "65", "", "", "84.5", "76.7", "", "56.0", "", "2", "", "", "201", "1", "1", "148", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "88.0", "88.8", "", "", "", "", "88.7"]} -{"pcdb_id": 15632, "brand_name": "Trianco", "model_name": "Contractor Combi", "model_qualifier": "110 HE", "winter_efficiency_pct": 86.4, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 55.5, "output_kw_max": 33.4, "final_year_of_manufacture": null, "raw": ["015632", "000062", "0", "2007/Sep/20 10:37", "Trianco Heating Products", "Trianco", "Contractor Combi", "110 HE", "2388", "2007", "current", "4", "1", "1", "2", "0", "", "", "2", "3", "2", "33.4", "33.4", "", "", "86.4", "79.0", "", "55.5", "", "2", "", "", "202", "1", "1", "148", "0", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "89.5", "91.2", "", "", "", "", "90.8"]} -{"pcdb_id": 15633, "brand_name": "Trianco", "model_name": "Contractor 110 HE EXT Combi", "model_qualifier": "", "winter_efficiency_pct": 86.4, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 55.5, "output_kw_max": 33.4, "final_year_of_manufacture": null, "raw": ["015633", "000062", "0", "2007/Sep/20 10:38", "Trianco Heating Products", "Trianco", "Contractor 110 HE EXT Combi", "", "", "2007", "current", "4", "1", "2", "2", "0", "", "", "2", "3", "2", "33.4", "33.4", "", "", "86.4", "79.0", "", "55.5", "", "2", "", "", "202", "1", "1", "148", "0", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "89.5", "91.2", "", "", "", "", "90.8"]} -{"pcdb_id": 15634, "brand_name": "Trianco", "model_name": "Iona", "model_qualifier": "110 HE Combi", "winter_efficiency_pct": 86.4, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 55.5, "output_kw_max": 33.4, "final_year_of_manufacture": null, "raw": ["015634", "000062", "0", "2007/Sep/20 10:40", "Trianco Heating Products", "Trianco", "Iona", "110 HE Combi", "2408", "2007", "current", "4", "1", "1", "2", "0", "", "", "2", "3", "2", "33.4", "33.4", "", "", "86.4", "79.0", "", "55.5", "", "2", "", "", "202", "1", "1", "148", "0", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "89.5", "91.2", "", "", "", "", "90.8"]} -{"pcdb_id": 15635, "brand_name": "Trianco", "model_name": "Iona 110 HE External Combi", "model_qualifier": "", "winter_efficiency_pct": 86.4, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 55.5, "output_kw_max": 33.4, "final_year_of_manufacture": null, "raw": ["015635", "000062", "0", "2007/Sep/20 10:41", "Trianco Heating Products", "Trianco", "Iona 110 HE External Combi", "", "", "2007", "current", "4", "1", "1", "2", "0", "", "", "2", "3", "2", "33.4", "33.4", "", "", "86.4", "79.0", "", "55.5", "", "2", "", "", "202", "1", "1", "148", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "89.5", "91.2", "", "", "", "", "90.8"]} -{"pcdb_id": 15636, "brand_name": "Trianco", "model_name": "Contractor", "model_qualifier": "50/70 WM HE", "winter_efficiency_pct": 86.0, "summer_efficiency_pct": 78.2, "comparative_hot_water_efficiency_pct": 57.2, "output_kw_max": 21.3, "final_year_of_manufacture": null, "raw": ["015636", "000062", "0", "2012/Mar/27 10:12", "Trianco Heating Products", "Trianco", "Contractor", "50/70 WM HE", "2385", "2007", "current", "4", "2", "1", "1", "0", "", "", "2", "2", "2", "14.88", "21.3", "", "", "86.0", "78.2", "", "57.2", "", "2", "", "", "201", "1", "1", "148", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "89.0", "91.0", "", "", "", "", "90.6"]} -{"pcdb_id": 15637, "brand_name": "Trianco", "model_name": "Contractor", "model_qualifier": "50/70 WM HE EXT", "winter_efficiency_pct": 86.0, "summer_efficiency_pct": 78.2, "comparative_hot_water_efficiency_pct": 57.2, "output_kw_max": 21.3, "final_year_of_manufacture": null, "raw": ["015637", "000062", "0", "2012/Mar/27 10:12", "Trianco Heating Products", "Trianco", "Contractor", "50/70 WM HE EXT", "2386", "2007", "current", "4", "2", "1", "1", "0", "", "", "2", "2", "2", "14.88", "21.3", "", "", "86.0", "78.2", "", "57.2", "", "2", "", "", "201", "1", "1", "148", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "89.0", "91.0", "", "", "", "", "90.6"]} -{"pcdb_id": 15638, "brand_name": "Trianco", "model_name": "Iona", "model_qualifier": "50/70 WM HE", "winter_efficiency_pct": 86.0, "summer_efficiency_pct": 78.2, "comparative_hot_water_efficiency_pct": 57.2, "output_kw_max": 21.3, "final_year_of_manufacture": null, "raw": ["015638", "000062", "0", "2012/Mar/27 10:12", "Trianco Heating Products", "Trianco", "Iona", "50/70 WM HE", "", "2007", "current", "4", "2", "1", "1", "0", "", "", "2", "2", "2", "14.88", "21.3", "", "", "86.0", "78.2", "", "57.2", "", "2", "", "", "201", "1", "1", "148", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "89.0", "91.0", "", "", "", "", "90.6"]} -{"pcdb_id": 15639, "brand_name": "Trianco", "model_name": "Iona", "model_qualifier": "50/70 WM HE External", "winter_efficiency_pct": 86.0, "summer_efficiency_pct": 78.2, "comparative_hot_water_efficiency_pct": 57.2, "output_kw_max": 21.3, "final_year_of_manufacture": null, "raw": ["015639", "000062", "0", "2012/Mar/27 10:12", "Trianco Heating Products", "Trianco", "Iona", "50/70 WM HE External", "2406", "2007", "current", "4", "2", "1", "1", "0", "", "", "2", "2", "2", "14.88", "21.3", "", "", "86.0", "78.2", "", "57.2", "", "2", "", "", "201", "1", "1", "148", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "89.0", "91.0", "", "", "", "", "90.6"]} -{"pcdb_id": 15641, "brand_name": "Biasi", "model_name": "Parva HE System", "model_qualifier": "M96.32SR/P", "winter_efficiency_pct": 87.4, "summer_efficiency_pct": 78.4, "comparative_hot_water_efficiency_pct": 57.3, "output_kw_max": 32.2, "final_year_of_manufacture": null, "raw": ["015641", "000208", "0", "2012/Mar/27 10:12", "Biasi (UK)", "Biasi", "Parva HE System", "M96.32SR/P", "", "2007", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "32.2", "32.2", "", "", "87.4", "78.4", "", "57.3", "", "2", "0", "", "102", "1", "2", "150", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.1", "92.7", "", "", "", "", "92.0"]} -{"pcdb_id": 15642, "brand_name": "Biasi", "model_name": "Parva HE System", "model_qualifier": "M96.32SR/P", "winter_efficiency_pct": 85.5, "summer_efficiency_pct": 76.5, "comparative_hot_water_efficiency_pct": 55.9, "output_kw_max": 32.2, "final_year_of_manufacture": null, "raw": ["015642", "000208", "0", "2012/Mar/27 10:12", "Biasi (UK)", "Biasi", "Parva HE System", "M96.32SR/P", "41-583-06", "2007", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "32.2", "32.2", "", "", "85.5", "76.5", "", "55.9", "", "2", "", "", "102", "1", "2", "150", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.1", "90.7", "", "", "", "", "90.0"]} -{"pcdb_id": 15644, "brand_name": "Biasi", "model_name": "Parva HE System", "model_qualifier": "M96.28SR/P", "winter_efficiency_pct": 86.3, "summer_efficiency_pct": 77.3, "comparative_hot_water_efficiency_pct": 56.5, "output_kw_max": 27.4, "final_year_of_manufacture": null, "raw": ["015644", "000208", "0", "2012/Mar/27 10:12", "Biasi (UK)", "Biasi", "Parva HE System", "M96.28SR/P", "", "2007", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "27.4", "27.4", "", "", "86.3", "77.3", "", "56.5", "", "2", "0", "", "102", "1", "2", "150", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.1", "91.4", "", "", "", "", "90.6"]} -{"pcdb_id": 15645, "brand_name": "Biasi", "model_name": "Parva HE Systen", "model_qualifier": "M96.28SR/P", "winter_efficiency_pct": 85.9, "summer_efficiency_pct": 76.9, "comparative_hot_water_efficiency_pct": 56.2, "output_kw_max": 28.3, "final_year_of_manufacture": null, "raw": ["015645", "000208", "0", "2012/Mar/27 10:12", "Biasi (UK)", "Biasi", "Parva HE Systen", "M96.28SR/P", "41-583-05", "2007", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "28.3", "28.3", "", "", "85.9", "76.9", "", "56.2", "", "2", "", "", "102", "1", "2", "150", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "91.5", "", "", "", "", "90.8"]} -{"pcdb_id": 15646, "brand_name": "Biasi", "model_name": "Parva HE Combi", "model_qualifier": "M96.32SM/P", "winter_efficiency_pct": 87.4, "summer_efficiency_pct": 78.8, "comparative_hot_water_efficiency_pct": 55.4, "output_kw_max": 32.2, "final_year_of_manufacture": null, "raw": ["015646", "000208", "0", "2007/Oct/09 08:37", "Biasi (UK)", "Biasi", "Parva HE Combi", "M96.32SM/P", "", "2007", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "32.2", "32.2", "", "", "87.4", "78.8", "", "55.4", "", "2", "0", "", "104", "1", "2", "150", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.1", "92.7", "", "", "", "", "92.0"]} -{"pcdb_id": 15647, "brand_name": "Biasi", "model_name": "Parva HE Combi", "model_qualifier": "M96.32SM/P", "winter_efficiency_pct": 85.5, "summer_efficiency_pct": 76.9, "comparative_hot_water_efficiency_pct": 54.1, "output_kw_max": 32.2, "final_year_of_manufacture": null, "raw": ["015647", "000208", "0", "2007/Sep/28 13:04", "Biasi (UK)", "Biasi", "Parva HE Combi", "M96.32SM/P", "47-583-10", "2007", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "32.2", "32.2", "", "", "85.5", "76.9", "", "54.1", "", "2", "", "", "104", "1", "2", "150", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.1", "90.7", "", "", "", "", "90.0"]} -{"pcdb_id": 15648, "brand_name": "Biasi", "model_name": "Parva HE Combi", "model_qualifier": "M96.28SM/P", "winter_efficiency_pct": 86.3, "summer_efficiency_pct": 77.7, "comparative_hot_water_efficiency_pct": 54.6, "output_kw_max": 27.4, "final_year_of_manufacture": null, "raw": ["015648", "000208", "0", "2007/Oct/09 08:38", "Biasi (UK)", "Biasi", "Parva HE Combi", "M96.28SM/P", "", "2007", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "27.4", "27.4", "", "", "86.3", "77.7", "", "54.6", "", "2", "0", "", "104", "1", "2", "150", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.1", "91.4", "", "", "", "", "90.6"]} -{"pcdb_id": 15649, "brand_name": "Biasi", "model_name": "Parva HE Combi", "model_qualifier": "M96.28SM/P", "winter_efficiency_pct": 85.9, "summer_efficiency_pct": 77.3, "comparative_hot_water_efficiency_pct": 54.4, "output_kw_max": 28.3, "final_year_of_manufacture": null, "raw": ["015649", "000208", "0", "2007/Sep/28 13:05", "Biasi (UK)", "Biasi", "Parva HE Combi", "M96.28SM/P", "47-583-09", "2007", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28.3", "28.3", "", "", "85.9", "77.3", "", "54.4", "", "2", "", "", "104", "1", "2", "150", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "91.5", "", "", "", "", "90.8"]} -{"pcdb_id": 15650, "brand_name": "Biasi", "model_name": "Parva HE Combi", "model_qualifier": "M96.24SM/P", "winter_efficiency_pct": 86.2, "summer_efficiency_pct": 77.6, "comparative_hot_water_efficiency_pct": 54.5, "output_kw_max": 23.7, "final_year_of_manufacture": null, "raw": ["015650", "000208", "0", "2007/Oct/09 08:38", "Biasi (UK)", "Biasi", "Parva HE Combi", "M96.24SM/P", "47-583-08", "2007", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "23.7", "23.7", "", "", "86.2", "77.6", "", "54.5", "", "2", "0", "", "104", "1", "2", "140", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.3", "90.8", "", "", "", "", "90.1"]} -{"pcdb_id": 15651, "brand_name": "Biasi", "model_name": "Parva HE Combi", "model_qualifier": "M96.24SM/P", "winter_efficiency_pct": 85.8, "summer_efficiency_pct": 77.2, "comparative_hot_water_efficiency_pct": 54.3, "output_kw_max": 24.6, "final_year_of_manufacture": null, "raw": ["015651", "000208", "0", "2007/Sep/28 13:05", "Biasi (UK)", "Biasi", "Parva HE Combi", "M96.24SM/P", "47-583-08", "2007", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.6", "24.6", "", "", "85.8", "77.2", "", "54.3", "", "2", "", "", "104", "1", "2", "140", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.7", "90.9", "", "", "", "", "90.5"]} -{"pcdb_id": 15652, "brand_name": "Ariston", "model_name": "Clas 24 FF", "model_qualifier": "", "winter_efficiency_pct": 82.4, "summer_efficiency_pct": 72.3, "comparative_hot_water_efficiency_pct": 50.9, "output_kw_max": 24.2, "final_year_of_manufacture": 2008, "raw": ["015652", "000080", "0", "2009/Jul/28 09:41", "Merloni TermoSanitari SpA", "Ariston", "Clas 24 FF", "", "47-116-59", "2007", "2008", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "24.2", "24.2", "", "", "82.4", "72.3", "", "50.9", "", "2", "", "", "104", "1", "2", "126", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "84.5", "84.3", "", "", "", "", "84.4"]} -{"pcdb_id": 15653, "brand_name": "Ariston", "model_name": "Clas 28 FF System", "model_qualifier": "", "winter_efficiency_pct": 82.4, "summer_efficiency_pct": 71.7, "comparative_hot_water_efficiency_pct": 52.4, "output_kw_max": 28.1, "final_year_of_manufacture": 2008, "raw": ["015653", "000080", "0", "2012/Mar/27 10:12", "Merloni TermoSanitari SpA", "Ariston", "Clas 28 FF System", "", "41-116-28", "2007", "2008", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "28.1", "28.1", "", "", "82.4", "71.7", "", "52.4", "", "2", "", "", "102", "1", "2", "126", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "84.3", "84.0", "", "", "", "", "84.0"]} -{"pcdb_id": 15654, "brand_name": "Ariston", "model_name": "Clas 21 FF System", "model_qualifier": "", "winter_efficiency_pct": 82.6, "summer_efficiency_pct": 71.9, "comparative_hot_water_efficiency_pct": 52.5, "output_kw_max": 24.2, "final_year_of_manufacture": 2008, "raw": ["015654", "000080", "0", "2012/Mar/27 10:12", "Merloni TermoSanitari SpA", "Ariston", "Clas 21 FF System", "", "41-116-27", "2007", "2008", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "24.2", "24.2", "", "", "82.6", "71.9", "", "52.5", "", "2", "", "", "102", "1", "2", "126", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "84.5", "84.3", "", "", "", "", "84.4"]} -{"pcdb_id": 15655, "brand_name": "Ariston", "model_name": "Clas HE 18 System", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 17.6, "final_year_of_manufacture": 2013, "raw": ["015655", "000080", "0", "2013/Nov/04 15:25", "Merloni TermoSanitari SpA", "Ariston", "Clas HE 18 System", "", "41-116-26", "2007", "2013", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "17.6", "17.6", "", "", "88.6", "79.6", "", "58.1", "", "2", "", "", "102", "1", "2", "105", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "98.2", "", "", "", "", "96.3"]} -{"pcdb_id": 15660, "brand_name": "Warmflow", "model_name": "G-Series", "model_qualifier": "GS25B", "winter_efficiency_pct": 85.2, "summer_efficiency_pct": 76.2, "comparative_hot_water_efficiency_pct": 55.7, "output_kw_max": 25.51, "final_year_of_manufacture": null, "raw": ["015660", "000063", "0", "2012/Mar/27 10:12", "Radiant Bruciatori SpA", "Warmflow", "G-Series", "GS25B", "", "2007", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "25.51", "25.51", "", "", "85.2", "76.2", "", "55.7", "", "2", "", "", "102", "1", "2", "210", "5.4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "85.8", "90.8", "", "", "", "", "89.9"]} -{"pcdb_id": 15661, "brand_name": "Warmflow", "model_name": "G-Series", "model_qualifier": "GS25A", "winter_efficiency_pct": 87.7, "summer_efficiency_pct": 78.7, "comparative_hot_water_efficiency_pct": 57.5, "output_kw_max": 26.67, "final_year_of_manufacture": null, "raw": ["015661", "000063", "0", "2012/Mar/27 10:12", "Radiant Bruciatori SpA", "Warmflow", "G-Series", "GS25A", "", "2007", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "26.67", "26.67", "", "", "87.7", "78.7", "", "57.5", "", "2", "", "", "102", "1", "2", "170", "5.4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.7", "95.8", "", "", "", "", "94.4"]} -{"pcdb_id": 15662, "brand_name": "Warmflow", "model_name": "G-Series", "model_qualifier": "GC29B", "winter_efficiency_pct": 84.9, "summer_efficiency_pct": 76.3, "comparative_hot_water_efficiency_pct": 53.7, "output_kw_max": 29.01, "final_year_of_manufacture": null, "raw": ["015662", "000063", "0", "2007/Nov/26 10:03", "Radiant Bruciatori SpA", "Warmflow", "G-Series", "GC29B", "", "2007", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "29.01", "29.01", "", "", "84.9", "76.3", "", "53.7", "", "2", "", "", "104", "1", "2", "175", "5.4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.1", "89.3", "", "", "", "", "88.9"]} -{"pcdb_id": 15663, "brand_name": "Warmflow", "model_name": "G-Series", "model_qualifier": "GC29A", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 55.9, "output_kw_max": 29.43, "final_year_of_manufacture": null, "raw": ["015663", "000063", "0", "2007/Nov/26 10:03", "Radiant Bruciatori SpA", "Warmflow", "G-Series", "GC29A", "", "2007", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "29.43", "29.43", "", "", "88.1", "79.5", "", "55.9", "", "2", "", "", "104", "1", "2", "180", "5.4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.4", "96.9", "", "", "", "", "95.3"]} -{"pcdb_id": 15665, "brand_name": "Worcester", "model_name": "Greenstar Camray System", "model_qualifier": "12/18", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 58.7, "output_kw_max": 18.0, "final_year_of_manufacture": 2015, "raw": ["015665", "000035", "0", "2020/Sep/08 09:52", "Worcester Bosch Group", "Worcester", "Greenstar Camray System", "12/18", "Greenstar Camray 12/18-RSO-GB Oil System", "2007", "2015", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "12", "18", "", "", "88.1", "80.3", "", "58.7", "", "2", "", "", "201", "1", "1", "255", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.4", "94.8", "", "", "", "", "94.2"]} -{"pcdb_id": 15666, "brand_name": "Worcester", "model_name": "Greenstar Camray System", "model_qualifier": "18/25", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 80.6, "comparative_hot_water_efficiency_pct": 58.9, "output_kw_max": 25.0, "final_year_of_manufacture": 2015, "raw": ["015666", "000035", "0", "2020/Sep/08 09:52", "Worcester Bosch Group", "Worcester", "Greenstar Camray System", "18/25", "Greenstar Camray 18/25-RSO-GB Oil System", "2007", "2015", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "18", "25", "", "", "88.4", "80.6", "", "58.9", "", "2", "", "", "201", "1", "1", "265", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.5", "95.9", "", "", "", "", "94.8"]} -{"pcdb_id": 15667, "brand_name": "Worcester", "model_name": "Greenstar Camray System", "model_qualifier": "25/32", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 81.1, "comparative_hot_water_efficiency_pct": 59.3, "output_kw_max": 30.0, "final_year_of_manufacture": 2015, "raw": ["015667", "000035", "0", "2020/Sep/08 10:00", "Worcester Bosch Group", "Worcester", "Greenstar Camray System", "25/32", "Greenstar Camray 25/32-RSO-GB Oil System", "2007", "2015", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "25", "30", "", "", "88.9", "81.1", "", "59.3", "", "2", "", "", "201", "1", "1", "265", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.5", "96.9", "", "", "", "", "95.9"]} -{"pcdb_id": 15668, "brand_name": "Sime", "model_name": "Murelle HE", "model_qualifier": "35 BFT", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 34.1, "final_year_of_manufacture": 2018, "raw": ["015668", "000213", "0", "2018/Mar/05 16:56", "Fonderie Sime S.p.A.", "Sime", "Murelle HE", "35 BFT", "", "2008", "2018", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "34.1", "34.1", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "145", "8", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.5", "96.2", "", "", "", "", "94.9"]} -{"pcdb_id": 15669, "brand_name": "Sime", "model_name": "Murelle HE", "model_qualifier": "35 BFT", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 34.1, "final_year_of_manufacture": 2018, "raw": ["015669", "000213", "0", "2018/Mar/05 16:56", "Fonderie Sime S.p.A.", "Sime", "Murelle HE", "35 BFT", "", "2008", "2018", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "34.1", "34.1", "", "", "89.0", "80.0", "", "58.4", "", "2", "1", "", "102", "1", "2", "145", "8", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "91.5", "98.4", "", "", "", "", "97.1"]} -{"pcdb_id": 15670, "brand_name": "Sime", "model_name": "Murelle HE", "model_qualifier": "35 BF", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 55.8, "output_kw_max": 34.1, "final_year_of_manufacture": 2018, "raw": ["015670", "000213", "0", "2018/Mar/05 16:55", "Fonderie Sime S.p.A.", "Sime", "Murelle HE", "35 BF", "", "2008", "2018", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "34.1", "34.1", "", "", "88.0", "79.4", "", "55.8", "", "2", "", "", "104", "1", "2", "140", "8", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.5", "96.2", "", "", "", "", "94.9"]} -{"pcdb_id": 15671, "brand_name": "Sime", "model_name": "Murelle HE", "model_qualifier": "35 BF", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.4, "comparative_hot_water_efficiency_pct": 56.6, "output_kw_max": 34.1, "final_year_of_manufacture": 2018, "raw": ["015671", "000213", "0", "2018/Mar/05 16:55", "Fonderie Sime S.p.A.", "Sime", "Murelle HE", "35 BF", "", "2008", "2018", "2", "2", "1", "2", "0", "", "", "2", "3", "2", "34.1", "34.1", "", "", "89.0", "80.4", "", "56.6", "", "2", "1", "", "104", "1", "2", "140", "8", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "91.5", "98.4", "", "", "", "", "97.1"]} -{"pcdb_id": 15672, "brand_name": "Sime", "model_name": "Murelle HE", "model_qualifier": "30 BFT", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 28.9, "final_year_of_manufacture": 2018, "raw": ["015672", "000213", "0", "2018/Mar/05 16:51", "Fonderie Sime S.p.A.", "Sime", "Murelle HE", "30 BFT", "", "2008", "2018", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "28.9", "28.9", "", "", "88.2", "79.2", "", "57.9", "", "2", "", "", "102", "1", "2", "135", "8", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.7", "97.0", "", "", "", "", "95.4"]} -{"pcdb_id": 15673, "brand_name": "Sime", "model_name": "Murelle HE", "model_qualifier": "30 BFT", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 28.9, "final_year_of_manufacture": 2018, "raw": ["015673", "000213", "0", "2018/Mar/05 16:52", "Fonderie Sime S.p.A.", "Sime", "Murelle HE", "30 BFT", "", "2008", "2018", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "28.9", "28.9", "", "", "89.2", "80.2", "", "58.6", "", "2", "1", "", "102", "1", "2", "135", "8", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.6", "99.2", "", "", "", "", "97.6"]} -{"pcdb_id": 15674, "brand_name": "Sime", "model_name": "Murelle HE", "model_qualifier": "30 BF", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 56.0, "output_kw_max": 28.9, "final_year_of_manufacture": 2018, "raw": ["015674", "000213", "0", "2018/Mar/05 16:50", "Fonderie Sime S.p.A.", "Sime", "Murelle HE", "30 BF", "", "2008", "2018", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "28.9", "28.9", "", "", "88.2", "79.6", "", "56.0", "", "2", "", "", "104", "1", "2", "130", "8", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.7", "97.0", "", "", "", "", "95.4"]} -{"pcdb_id": 15675, "brand_name": "Sime", "model_name": "Murelle HE", "model_qualifier": "30 BF", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 80.6, "comparative_hot_water_efficiency_pct": 56.7, "output_kw_max": 28.9, "final_year_of_manufacture": 2018, "raw": ["015675", "000213", "0", "2018/Mar/05 16:51", "Fonderie Sime S.p.A.", "Sime", "Murelle HE", "30 BF", "", "2008", "2018", "2", "2", "1", "2", "0", "", "", "2", "3", "2", "28.9", "28.9", "", "", "89.2", "80.6", "", "56.7", "", "2", "1", "", "104", "1", "2", "130", "8", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.6", "99.2", "", "", "", "", "97.6"]} -{"pcdb_id": 15676, "brand_name": "Sime", "model_name": "Murelle HE", "model_qualifier": "25 BFT", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 23.9, "final_year_of_manufacture": 2018, "raw": ["015676", "000213", "0", "2018/Mar/05 16:43", "Fonderie Sime S.p.A.", "Sime", "Murelle HE", "25 BFT", "", "2008", "2018", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "23.9", "23.9", "", "", "88.2", "79.2", "", "57.9", "", "2", "", "", "102", "1", "2", "130", "8", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.5", "97.1", "", "", "", "", "95.5"]} -{"pcdb_id": 15677, "brand_name": "Sime", "model_name": "Murelle HE", "model_qualifier": "25 BFT", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 23.9, "final_year_of_manufacture": 2018, "raw": ["015677", "000213", "0", "2018/Mar/05 16:44", "Fonderie Sime S.p.A.", "Sime", "Murelle HE", "25 BFT", "", "2008", "2018", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "23.9", "23.9", "", "", "89.2", "80.2", "", "58.6", "", "2", "1", "", "102", "1", "2", "130", "8", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.4", "99.3", "", "", "", "", "97.6"]} -{"pcdb_id": 15678, "brand_name": "Sime", "model_name": "Murelle HE", "model_qualifier": "25 BF", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 56.0, "output_kw_max": 23.9, "final_year_of_manufacture": 2018, "raw": ["015678", "000213", "0", "2018/Mar/05 16:42", "Fonderie Sime S.p.A.", "Sime", "Murelle HE", "25 BF", "", "2008", "2018", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "23.9", "23.9", "", "", "88.2", "79.6", "", "56.0", "", "2", "", "", "104", "1", "2", "125", "8", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.5", "97.1", "", "", "", "", "95.5"]} -{"pcdb_id": 15679, "brand_name": "Sime", "model_name": "Murelle HE", "model_qualifier": "25 BF", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 80.6, "comparative_hot_water_efficiency_pct": 56.7, "output_kw_max": 23.9, "final_year_of_manufacture": 2018, "raw": ["015679", "000213", "0", "2018/Mar/05 16:42", "Fonderie Sime S.p.A.", "Sime", "Murelle HE", "25 BF", "", "2008", "2018", "2", "2", "1", "2", "0", "", "", "2", "3", "2", "23.9", "23.9", "", "", "89.2", "80.6", "", "56.7", "", "2", "1", "", "104", "1", "2", "125", "8", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.4", "99.3", "", "", "", "", "97.6"]} -{"pcdb_id": 15680, "brand_name": "Sime", "model_name": "Murelle HE", "model_qualifier": "20 BFT", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 19.0, "final_year_of_manufacture": 2018, "raw": ["015680", "000213", "0", "2018/Mar/05 16:40", "Fonderie Sime S.p.A.", "Sime", "Murelle HE", "20 BFT", "", "2008", "2018", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "19", "19", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "125", "8", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.2", "96.8", "", "", "", "", "95.1"]} -{"pcdb_id": 15681, "brand_name": "Sime", "model_name": "Murelle HE", "model_qualifier": "20 BFT", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 19.0, "final_year_of_manufacture": 2018, "raw": ["015681", "000213", "0", "2018/Mar/05 16:41", "Fonderie Sime S.p.A.", "Sime", "Murelle HE", "20 BFT", "", "2008", "2018", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "19", "19", "", "", "89.0", "80.0", "", "58.5", "", "2", "1", "", "102", "1", "2", "125", "8", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.2", "98.9", "", "", "", "", "97.3"]} -{"pcdb_id": 15682, "brand_name": "Sime", "model_name": "Murelle HE", "model_qualifier": "12 BFT", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 11.7, "final_year_of_manufacture": 2018, "raw": ["015682", "000213", "0", "2018/Mar/05 16:37", "Fonderie Sime S.p.A.", "Sime", "Murelle HE", "12 BFT", "", "2008", "2018", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "11.7", "11.7", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "115", "8", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.2", "96.6", "", "", "", "", "95.0"]} -{"pcdb_id": 15683, "brand_name": "Sime", "model_name": "Murelle HE", "model_qualifier": "12 BFT", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 11.7, "final_year_of_manufacture": 2018, "raw": ["015683", "000213", "0", "2018/Mar/05 16:38", "Fonderie Sime S.p.A.", "Sime", "Murelle HE", "12 BFT", "", "2008", "2018", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "11.7", "11.7", "", "", "89.0", "80.0", "", "58.4", "", "2", "1", "", "102", "1", "2", "115", "8", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.2", "98.7", "", "", "", "", "97.1"]} -{"pcdb_id": 15684, "brand_name": "Ideal", "model_name": "Esprit", "model_qualifier": "HE 24", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 56.0, "output_kw_max": 23.4, "final_year_of_manufacture": 2010, "raw": ["015684", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "Esprit", "HE 24", "47-348-46", "2007", "2010", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "8.8", "23.4", "", "", "88.3", "79.7", "", "56.0", "", "2", "", "", "104", "1", "2", "140", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.1", "97.4", "", "", "", "", "95.6"]} -{"pcdb_id": 15685, "brand_name": "Ideal", "model_name": "Esprit", "model_qualifier": "HE 30", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 56.0, "output_kw_max": 29.3, "final_year_of_manufacture": 2010, "raw": ["015685", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "Esprit", "HE 30", "47-348-47", "2007", "2010", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "8.8", "29.3", "", "", "88.3", "79.7", "", "56.0", "", "2", "", "", "104", "1", "2", "175", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.1", "97.4", "", "", "", "", "95.6"]} -{"pcdb_id": 15686, "brand_name": "Ideal", "model_name": "Esprit", "model_qualifier": "HE 35", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 56.0, "output_kw_max": 35.2, "final_year_of_manufacture": 2010, "raw": ["015686", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "Esprit", "HE 35", "47-348-48", "2007", "2010", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "8.8", "35.2", "", "", "88.3", "79.7", "", "56.0", "", "2", "", "", "104", "1", "2", "170", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.1", "97.4", "", "", "", "", "95.6"]} -{"pcdb_id": 15687, "brand_name": "Ideal", "model_name": "Elise", "model_qualifier": "H15", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 14.6, "final_year_of_manufacture": 2010, "raw": ["015687", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "Elise", "H15", "41-399-97", "2007", "2010", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "14.6", "14.6", "", "", "89.0", "80.0", "", "58.4", "", "2", "", "", "102", "1", "2", "38", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.5", "99.0", "", "", "", "", "97.0"]} -{"pcdb_id": 15688, "brand_name": "Ideal", "model_name": "Elise", "model_qualifier": "H24", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 23.4, "final_year_of_manufacture": 2010, "raw": ["015688", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "Elise", "H24", "41-399-98", "2007", "2010", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "23.4", "23.4", "", "", "88.1", "79.1", "", "57.8", "", "2", "", "", "102", "1", "2", "38", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "97.1", "", "", "", "", "95.4"]} -{"pcdb_id": 15689, "brand_name": "Baxi", "model_name": "Megaflo System", "model_qualifier": "15 HE A", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 15.0, "final_year_of_manufacture": 2015, "raw": ["015689", "000005", "0", "2015/Aug/06 10:39", "Baxi Heating", "Baxi", "Megaflo System", "15 HE A", "GC No. 41-075-55", "2008", "2015", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "15", "15", "", "", "88.3", "79.3", "", "57.9", "", "2", "", "", "102", "1", "2", "130", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.9", "96.8", "", "", "", "", "95.5"]} -{"pcdb_id": 15690, "brand_name": "Baxi", "model_name": "Megaflo System", "model_qualifier": "18 HE A", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 18.0, "final_year_of_manufacture": 2015, "raw": ["015690", "000005", "0", "2015/Aug/06 11:47", "Baxi Heating", "Baxi", "Megaflo System", "18 HE A", "GC No. 41-075-56", "2008", "2015", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18", "18", "", "", "88.3", "79.3", "", "58.0", "", "2", "", "", "102", "1", "2", "140", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.9", "96.9", "", "", "", "", "95.5"]} -{"pcdb_id": 15691, "brand_name": "Baxi", "model_name": "Megaflo System", "model_qualifier": "24 HE A", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 24.0, "final_year_of_manufacture": 2015, "raw": ["015691", "000005", "0", "2015/Aug/06 11:48", "Baxi Heating", "Baxi", "Megaflo System", "24 HE A", "GC No 41-075-57", "2008", "2015", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24", "24", "", "", "88.3", "79.3", "", "58.0", "", "2", "", "", "102", "1", "2", "150", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.9", "96.9", "", "", "", "", "95.5"]} -{"pcdb_id": 15692, "brand_name": "Baxi", "model_name": "Megaflo System", "model_qualifier": "28 HE A", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 28.0, "final_year_of_manufacture": 2015, "raw": ["015692", "000005", "0", "2015/Aug/06 11:48", "Baxi Heating", "Baxi", "Megaflo System", "28 HE A", "GC No 41-075-58", "2008", "2015", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "28", "28", "", "", "88.3", "79.3", "", "57.9", "", "2", "", "", "102", "1", "2", "160", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.9", "96.7", "", "", "", "", "95.4"]} -{"pcdb_id": 15693, "brand_name": "Baxi", "model_name": "Megaflo System", "model_qualifier": "32 HE A", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 32.0, "final_year_of_manufacture": 2015, "raw": ["015693", "000005", "0", "2015/Aug/06 11:49", "Baxi Heating", "Baxi", "Megaflo System", "32 HE A", "GC No. 41-075-59", "2008", "2015", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "32", "32", "", "", "88.3", "79.3", "", "57.9", "", "2", "", "", "102", "1", "2", "160", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.9", "96.7", "", "", "", "", "95.4"]} -{"pcdb_id": 15694, "brand_name": "Baxi", "model_name": "Platinum Combi", "model_qualifier": "24 HE A", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 56.1, "output_kw_max": 24.0, "final_year_of_manufacture": 2015, "raw": ["015694", "000005", "0", "2015/Aug/06 11:49", "Baxi Heating", "Baxi", "Platinum Combi", "24 HE A", "GC No 47-075-31", "2008", "2015", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "88.4", "79.8", "", "56.1", "", "2", "", "", "104", "1", "2", "155", "5", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "90.0", "96.9", "", "", "", "", "95.6"]} -{"pcdb_id": 15695, "brand_name": "Baxi", "model_name": "Platinum Combi", "model_qualifier": "28 HE A", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 56.1, "output_kw_max": 24.0, "final_year_of_manufacture": 2015, "raw": ["015695", "000005", "0", "2015/Aug/06 11:51", "Baxi Heating", "Baxi", "Platinum Combi", "28 HE A", "GC No 47-075-32", "2008", "2015", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "88.4", "79.8", "", "56.1", "", "2", "", "", "104", "1", "2", "155", "5", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "90.0", "96.9", "", "", "", "", "95.6"]} -{"pcdb_id": 15696, "brand_name": "Baxi", "model_name": "Platinum Combi", "model_qualifier": "33 HE A", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 56.0, "output_kw_max": 28.0, "final_year_of_manufacture": 2015, "raw": ["015696", "000005", "0", "2015/Aug/06 11:51", "Baxi Heating", "Baxi", "Platinum Combi", "33 HE A", "GC No 47-075-33", "2008", "2015", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28", "28", "", "", "88.3", "79.7", "", "56.0", "", "2", "", "", "104", "1", "2", "160", "5", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "90.0", "96.7", "", "", "", "", "95.4"]} -{"pcdb_id": 15697, "brand_name": "Baxi", "model_name": "Platinum Combi", "model_qualifier": "40 HE A", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 56.0, "output_kw_max": 32.0, "final_year_of_manufacture": 2015, "raw": ["015697", "000005", "0", "2015/Aug/06 11:52", "Baxi Heating", "Baxi", "Platinum Combi", "40 HE A", "GC No 47-075-34", "2008", "2015", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "32", "32", "", "", "88.3", "79.7", "", "56.0", "", "2", "", "", "104", "1", "2", "160", "5", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "90.0", "96.7", "", "", "", "", "95.4"]} -{"pcdb_id": 15700, "brand_name": "Main", "model_name": "Combi", "model_qualifier": "30 Eco", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 55.9, "output_kw_max": 28.63, "final_year_of_manufacture": 2012, "raw": ["015700", "000005", "0", "2015/Aug/06 13:10", "Baxi Heating", "Main", "Combi", "30 Eco", "GC No. 47-467-03", "2008", "2012", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28.63", "28.63", "", "", "88.1", "79.5", "", "55.9", "", "2", "", "", "104", "1", "2", "150", "6", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "97.0", "", "", "", "", "95.3"]} -{"pcdb_id": 15701, "brand_name": "Main", "model_name": "Combi", "model_qualifier": "25 Eco", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 56.1, "output_kw_max": 25.94, "final_year_of_manufacture": 2012, "raw": ["015701", "000005", "0", "2013/May/07 10:33", "Baxi Heating", "Main", "Combi", "25 Eco", "GC No. 47-467-01", "2008", "2012", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "25.94", "25.94", "", "", "88.4", "79.8", "", "56.1", "", "2", "", "", "104", "1", "2", "150", "8", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.7", "97.0", "", "", "", "", "95.7"]} -{"pcdb_id": 15702, "brand_name": "Main", "model_name": "System", "model_qualifier": "28 Eco", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 28.63, "final_year_of_manufacture": 2012, "raw": ["015702", "000005", "0", "2013/May/07 10:34", "Baxi Heating", "Main", "System", "28 Eco", "GC No. 41-467-12", "2008", "2012", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "28.63", "28.63", "", "", "88.1", "79.1", "", "57.8", "", "2", "", "", "102", "1", "2", "150", "8", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "97.0", "", "", "", "", "95.3"]} -{"pcdb_id": 15703, "brand_name": "Main", "model_name": "System", "model_qualifier": "24 Eco", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 25.94, "final_year_of_manufacture": 2012, "raw": ["015703", "000005", "0", "2013/May/07 10:34", "Baxi Heating", "Main", "System", "24 Eco", "GC No. 41-467-11", "2008", "2012", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "25.94", "25.94", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "150", "8", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.7", "97.0", "", "", "", "", "95.7"]} -{"pcdb_id": 15704, "brand_name": "Baxi", "model_name": "Duo-tec Combi", "model_qualifier": "40 HE A", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 56.0, "output_kw_max": 32.0, "final_year_of_manufacture": 2015, "raw": ["015704", "000005", "0", "2015/Aug/06 11:53", "Baxi Heating", "Baxi", "Duo-tec Combi", "40 HE A", "GC No 47-075-38", "2008", "2015", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "32", "32", "", "", "88.3", "79.7", "", "56.0", "", "2", "", "", "104", "1", "2", "160", "5", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "90.0", "96.7", "", "", "", "", "95.4"]} -{"pcdb_id": 15705, "brand_name": "Baxi", "model_name": "Duo-tec Combi", "model_qualifier": "33 HE A", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 56.0, "output_kw_max": 28.0, "final_year_of_manufacture": 2015, "raw": ["015705", "000005", "0", "2015/Aug/06 11:53", "Baxi Heating", "Baxi", "Duo-tec Combi", "33 HE A", "GC No. 47-075-37", "2008", "2015", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28", "28", "", "", "88.3", "79.7", "", "56.0", "", "2", "", "", "104", "1", "2", "160", "5", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "90.0", "96.7", "", "", "", "", "95.4"]} -{"pcdb_id": 15706, "brand_name": "Baxi", "model_name": "Duo-tec Combi", "model_qualifier": "28 HE A", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 56.1, "output_kw_max": 24.0, "final_year_of_manufacture": 2015, "raw": ["015706", "000005", "0", "2015/Aug/06 11:54", "Baxi Heating", "Baxi", "Duo-tec Combi", "28 HE A", "GC No. 47-075-36", "2007", "2015", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "88.4", "79.8", "", "56.1", "", "2", "", "", "104", "1", "2", "155", "5", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "90.0", "96.9", "", "", "", "", "95.6"]} -{"pcdb_id": 15707, "brand_name": "Baxi", "model_name": "Duo-tec Combi", "model_qualifier": "24 HE A", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 56.1, "output_kw_max": 20.0, "final_year_of_manufacture": 2015, "raw": ["015707", "000005", "0", "2015/Aug/06 11:55", "Baxi Heating", "Baxi", "Duo-tec Combi", "24 HE A", "GC No. 47-075-35", "2008", "2015", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "20.0", "20.0", "", "", "88.4", "79.8", "", "56.1", "", "2", "", "", "104", "1", "2", "155", "5", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "90.0", "96.9", "", "", "", "", "95.6"]} -{"pcdb_id": 15708, "brand_name": "Potterton", "model_name": "Promax Combi", "model_qualifier": "33 HE Plus A", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 56.0, "output_kw_max": 28.0, "final_year_of_manufacture": 2015, "raw": ["015708", "000005", "0", "2015/Aug/06 12:52", "Baxi Heating", "Potterton", "Promax Combi", "33 HE Plus A", "GC No. 47-393-23", "2008", "2015", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28", "28", "", "", "88.3", "79.7", "", "56.0", "", "2", "", "", "104", "1", "2", "160", "5", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "90.0", "96.7", "", "", "", "", "95.4"]} -{"pcdb_id": 15709, "brand_name": "Potterton", "model_name": "Promax Combi", "model_qualifier": "28 HE Plus A", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 56.1, "output_kw_max": 24.0, "final_year_of_manufacture": 2015, "raw": ["015709", "000005", "0", "2015/Aug/06 12:52", "Baxi Heating", "Potterton", "Promax Combi", "28 HE Plus A", "GC No 47-393-22", "2008", "2015", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "88.4", "79.8", "", "56.1", "", "2", "", "", "104", "1", "2", "155", "5", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "90.0", "96.9", "", "", "", "", "95.6"]} -{"pcdb_id": 15710, "brand_name": "Potterton", "model_name": "Promax Combi", "model_qualifier": "24 HE Plus A", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 56.1, "output_kw_max": 20.0, "final_year_of_manufacture": 2015, "raw": ["015710", "000005", "0", "2015/Aug/06 12:53", "Baxi Heating", "Potterton", "Promax Combi", "24 HE Plus A", "GC No. 47-393-21", "2008", "2015", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "20", "20", "", "", "88.4", "79.8", "", "56.1", "", "2", "", "", "104", "1", "2", "155", "5", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "90.0", "96.9", "", "", "", "", "95.6"]} -{"pcdb_id": 15711, "brand_name": "ATAG", "model_name": "Q25SC", "model_qualifier": "", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 21.9, "final_year_of_manufacture": null, "raw": ["015711", "000227", "0", "2013/Oct/23 12:58", "ATAG Verwarming Nederland BV", "ATAG", "Q25SC", "", "GC No. 41-310-08", "2007", "current", "1", "1", "1", "1", "0", "", "", "2", "3", "2", "21.9", "21.9", "", "", "88.9", "79.9", "", "58.3", "", "2", "", "", "102", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.2", "98.9", "", "", "", "", "96.9"]} -{"pcdb_id": 15712, "brand_name": "ATAG", "model_name": "Q38SC", "model_qualifier": "", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 33.3, "final_year_of_manufacture": null, "raw": ["015712", "000227", "0", "2013/Oct/23 12:58", "ATAG Verwarming Nederland BV", "ATAG", "Q38SC", "", "GC No. 41-310-09", "2007", "current", "1", "1", "1", "1", "0", "", "", "2", "3", "2", "33.3", "33.3", "", "", "88.7", "79.7", "", "58.3", "", "2", "", "", "102", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "98.7", "", "", "", "", "96.7"]} -{"pcdb_id": 15714, "brand_name": "Gerkros", "model_name": "14.6 - 20.5 kW Oil Condensing Combi Boiler", "model_qualifier": "", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 56.6, "output_kw_max": 20.69, "final_year_of_manufacture": null, "raw": ["015714", "000245", "0", "2008/Feb/06 12:54", "Gerkros Boilers (Tipperary) Limited", "Gerkros", "14.6 - 20.5 kW Oil Condensing Combi Boiler", "", "", "2007", "current", "4", "1", "2", "2", "0", "", "", "2", "3", "1", "14.65", "20.69", "", "", "87.9", "80.5", "", "56.6", "", "2", "", "", "202", "1", "1", "250", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.3", "94.4", "", "", "", "", "93.8"]} -{"pcdb_id": 15716, "brand_name": "Gerkros", "model_name": "20.5 - 26.4 kW Oil Condensing Combi Boiler", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 80.6, "comparative_hot_water_efficiency_pct": 56.7, "output_kw_max": 27.06, "final_year_of_manufacture": null, "raw": ["015716", "000245", "0", "2008/Feb/06 12:53", "Gerkros Boilers (Tipperary) Limited", "Gerkros", "20.5 - 26.4 kW Oil Condensing Combi Boiler", "", "", "2007", "current", "4", "1", "2", "2", "0", "", "", "2", "3", "1", "20.69", "27.06", "", "", "88.0", "80.6", "", "56.7", "", "2", "", "", "202", "1", "1", "250", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.9", "94.7", "", "", "", "", "94.0"]} -{"pcdb_id": 15717, "brand_name": "Warmflow", "model_name": "Kabin Pak", "model_qualifier": "KP150HE", "winter_efficiency_pct": 87.5, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 44.0, "final_year_of_manufacture": null, "raw": ["015717", "000063", "0", "2013/Mar/28 08:29", "Warmflow Engineering", "Warmflow", "Kabin Pak", "KP150HE", "", "2008", "current", "4", "1", "2", "1", "0", "", "", "2", "1", "2", "33", "44", "", "", "87.5", "79.7", "", "58.2", "", "2", "", "", "201", "1", "1", "230", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "89.6", "94.1", "", "", "", "", "93.2"]} -{"pcdb_id": 15718, "brand_name": "Warmflow", "model_name": "Kabin Pak", "model_qualifier": "K150HE", "winter_efficiency_pct": 87.5, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 44.0, "final_year_of_manufacture": null, "raw": ["015718", "000063", "0", "2013/Mar/28 08:29", "Warmflow Engineering", "Warmflow", "Kabin Pak", "K150HE", "", "2008", "current", "4", "1", "2", "1", "0", "", "", "2", "1", "2", "33", "44", "", "", "87.5", "79.7", "", "58.2", "", "2", "", "", "201", "1", "1", "160", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "89.6", "94.1", "", "", "", "", "93.2"]} -{"pcdb_id": 15719, "brand_name": "Warmflow", "model_name": "Utility", "model_qualifier": "UP150HE", "winter_efficiency_pct": 87.5, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 44.0, "final_year_of_manufacture": null, "raw": ["015719", "000063", "0", "2013/Mar/28 08:29", "Warmflow Engineering", "Warmflow", "Utility", "UP150HE", "", "2008", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "33", "44", "", "", "87.5", "79.7", "", "58.2", "", "2", "", "", "201", "1", "1", "230", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "89.6", "94.1", "", "", "", "", "93.2"]} -{"pcdb_id": 15721, "brand_name": "Fondital", "model_name": "Tahiti Condensing KRB 32 Line Tech", "model_qualifier": "", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 78.9, "comparative_hot_water_efficiency_pct": 57.6, "output_kw_max": 30.6, "final_year_of_manufacture": null, "raw": ["015721", "000250", "0", "2012/Mar/27 10:12", "Fondital SpA", "Fondital", "Tahiti Condensing KRB 32 Line Tech", "", "", "2007", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "30.6", "30.6", "", "", "87.9", "78.9", "", "57.6", "", "2", "", "", "102", "1", "2", "155", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "96.6", "", "", "", "", "94.9"]} -{"pcdb_id": 15722, "brand_name": "Fondital", "model_name": "Tahiti Condensing KRB 32 Line Tech", "model_qualifier": "", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 30.6, "final_year_of_manufacture": null, "raw": ["015722", "000250", "0", "2012/Mar/27 10:12", "Fondital SpA", "Fondital", "Tahiti Condensing KRB 32 Line Tech", "", "", "2007", "current", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "30.6", "30.6", "", "", "88.9", "79.9", "", "58.4", "", "2", "1", "", "102", "1", "2", "155", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.9", "98.7", "", "", "", "", "97.1"]} -{"pcdb_id": 15723, "brand_name": "Fondital", "model_name": "Tahiti Condensing KRB 28 Line Tech", "model_qualifier": "", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 78.9, "comparative_hot_water_efficiency_pct": 57.6, "output_kw_max": 25.55, "final_year_of_manufacture": null, "raw": ["015723", "000250", "0", "2012/Mar/27 10:12", "Fondital SpA", "Fondital", "Tahiti Condensing KRB 28 Line Tech", "", "", "2007", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "25.55", "25.55", "", "", "87.9", "78.9", "", "57.6", "", "2", "", "", "102", "1", "2", "155", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "96.5", "", "", "", "", "94.9"]} -{"pcdb_id": 15724, "brand_name": "Fondital", "model_name": "Tahiti Condensing KRB 28 Line Tech", "model_qualifier": "", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 25.55, "final_year_of_manufacture": null, "raw": ["015724", "000250", "0", "2012/Mar/27 10:12", "Fondital SpA", "Fondital", "Tahiti Condensing KRB 28 Line Tech", "", "", "2007", "current", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "25.55", "25.55", "", "", "88.9", "79.9", "", "58.3", "", "2", "1", "", "102", "1", "2", "155", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.8", "98.6", "", "", "", "", "97.0"]} -{"pcdb_id": 15725, "brand_name": "Fondital", "model_name": "Tahiti Condensing KRB 24 Line Tech", "model_qualifier": "", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 78.9, "comparative_hot_water_efficiency_pct": 57.6, "output_kw_max": 23.1, "final_year_of_manufacture": null, "raw": ["015725", "000250", "0", "2012/Mar/27 10:12", "Fondital SpA", "Fondital", "Tahiti Condensing KRB 24 Line Tech", "", "", "2007", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "23.1", "23.1", "", "", "87.9", "78.9", "", "57.6", "", "2", "", "", "102", "1", "2", "155", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "96.5", "", "", "", "", "94.9"]} -{"pcdb_id": 15726, "brand_name": "Fondital", "model_name": "Tahiti Condensing KRB 24 Line Tech", "model_qualifier": "", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 23.1, "final_year_of_manufacture": null, "raw": ["015726", "000250", "0", "2012/Mar/27 10:12", "Fondital SpA", "Fondital", "Tahiti Condensing KRB 24 Line Tech", "", "", "2007", "current", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "23.1", "23.1", "", "", "88.9", "79.9", "", "58.3", "", "2", "1", "", "102", "1", "2", "155", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.8", "98.6", "", "", "", "", "97.0"]} -{"pcdb_id": 15727, "brand_name": "Fondital", "model_name": "Tahiti Condensing KR 32 Line Tech", "model_qualifier": "", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 78.9, "comparative_hot_water_efficiency_pct": 57.6, "output_kw_max": 30.6, "final_year_of_manufacture": null, "raw": ["015727", "000250", "0", "2012/Mar/27 10:12", "Fondital SpA", "Fondital", "Tahiti Condensing KR 32 Line Tech", "", "", "2006", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "30.6", "30.6", "", "", "87.9", "78.9", "", "57.6", "", "2", "", "", "102", "1", "2", "155", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "96.6", "", "", "", "", "94.9"]} -{"pcdb_id": 15728, "brand_name": "Fondital", "model_name": "Tahiti Condensing KR 32 Line Tech", "model_qualifier": "", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 30.6, "final_year_of_manufacture": null, "raw": ["015728", "000250", "0", "2012/Mar/27 10:12", "Fondital SpA", "Fondital", "Tahiti Condensing KR 32 Line Tech", "", "", "2006", "current", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "30.6", "30.6", "", "", "88.9", "79.9", "", "58.4", "", "2", "1", "", "102", "1", "2", "155", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.9", "98.7", "", "", "", "", "97.1"]} -{"pcdb_id": 15729, "brand_name": "Fondital", "model_name": "Tahiti Condensing KR 28 Line Tech", "model_qualifier": "", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 78.9, "comparative_hot_water_efficiency_pct": 57.6, "output_kw_max": 25.55, "final_year_of_manufacture": null, "raw": ["015729", "000250", "0", "2012/Mar/27 10:12", "Fondital SpA", "Fondital", "Tahiti Condensing KR 28 Line Tech", "", "", "2007", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "25.55", "25.55", "", "", "87.9", "78.9", "", "57.6", "", "2", "", "", "102", "1", "2", "155", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "96.5", "", "", "", "", "94.9"]} -{"pcdb_id": 15730, "brand_name": "Fondital", "model_name": "Tahiti Condensing KR 28 Line Tech", "model_qualifier": "", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 25.55, "final_year_of_manufacture": null, "raw": ["015730", "000250", "0", "2012/Mar/27 10:12", "Fondital SpA", "Fondital", "Tahiti Condensing KR 28 Line Tech", "", "", "2007", "current", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "25.55", "25.55", "", "", "88.9", "79.9", "", "58.3", "", "2", "1", "", "102", "1", "2", "155", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.8", "98.6", "", "", "", "", "97.0"]} -{"pcdb_id": 15731, "brand_name": "Fondital", "model_name": "Tahiti Condensing KR 24 Line Tech", "model_qualifier": "", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 78.9, "comparative_hot_water_efficiency_pct": 57.6, "output_kw_max": 23.1, "final_year_of_manufacture": null, "raw": ["015731", "000250", "0", "2012/Mar/27 10:12", "Fondital SpA", "Fondital", "Tahiti Condensing KR 24 Line Tech", "", "", "2006", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "23.1", "23.1", "", "", "87.9", "78.9", "", "57.6", "", "2", "", "", "102", "1", "2", "155", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "96.5", "", "", "", "", "94.9"]} -{"pcdb_id": 15732, "brand_name": "Fondital", "model_name": "Tahiti Condensing KR 24 Line Tech", "model_qualifier": "", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 23.1, "final_year_of_manufacture": null, "raw": ["015732", "000250", "0", "2012/Mar/27 10:12", "Fondital SpA", "Fondital", "Tahiti Condensing KR 24 Line Tech", "", "", "2006", "current", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "23.1", "23.1", "", "", "88.9", "79.9", "", "58.3", "", "2", "1", "", "102", "1", "2", "155", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.8", "98.6", "", "", "", "", "97.0"]} -{"pcdb_id": 15733, "brand_name": "Fondital", "model_name": "Tahiti Condensing KC 32 Line Tech", "model_qualifier": "", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 55.8, "output_kw_max": 30.6, "final_year_of_manufacture": null, "raw": ["015733", "000250", "0", "2008/Feb/29 10:31", "Fondital SpA", "Fondital", "Tahiti Condensing KC 32 Line Tech", "", "", "2006", "current", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "30.6", "30.6", "", "", "87.9", "79.3", "", "55.8", "", "2", "", "", "104", "1", "2", "155", "10", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "96.6", "", "", "", "", "94.9"]} -{"pcdb_id": 15734, "brand_name": "Fondital", "model_name": "Tahiti Condensing KC 32 Line Tech", "model_qualifier": "", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 56.5, "output_kw_max": 30.6, "final_year_of_manufacture": null, "raw": ["015734", "000250", "0", "2008/Feb/29 10:31", "Fondital SpA", "Fondital", "Tahiti Condensing KC 32 Line Tech", "", "", "2006", "current", "2", "2", "1", "2", "0", "", "", "2", "3", "2", "30.6", "30.6", "", "", "88.9", "80.3", "", "56.5", "", "2", "1", "", "104", "1", "2", "155", "10", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.9", "98.7", "", "", "", "", "97.1"]} -{"pcdb_id": 15735, "brand_name": "Fondital", "model_name": "Tahiti Condensing KC 28 Line Tech", "model_qualifier": "", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 55.7, "output_kw_max": 25.55, "final_year_of_manufacture": null, "raw": ["015735", "000250", "0", "2008/Feb/29 10:31", "Fondital SpA", "Fondital", "Tahiti Condensing KC 28 Line Tech", "", "", "2007", "current", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "25.55", "25.55", "", "", "87.9", "79.3", "", "55.7", "", "2", "", "", "104", "1", "2", "155", "10", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "96.5", "", "", "", "", "94.9"]} -{"pcdb_id": 15736, "brand_name": "Fondital", "model_name": "Tahiti Condensing KC 28 Line Tech", "model_qualifier": "", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 56.4, "output_kw_max": 25.55, "final_year_of_manufacture": null, "raw": ["015736", "000250", "0", "2008/Feb/29 10:31", "Fondital SpA", "Fondital", "Tahiti Condensing KC 28 Line Tech", "", "", "2007", "current", "2", "2", "1", "2", "0", "", "", "2", "3", "2", "25.55", "25.55", "", "", "88.9", "80.3", "", "56.4", "", "2", "1", "", "104", "1", "2", "155", "10", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.8", "98.6", "", "", "", "", "97.0"]} -{"pcdb_id": 15737, "brand_name": "Fondital", "model_name": "Tahiti Condensing KC 24 Line Tech", "model_qualifier": "", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 55.7, "output_kw_max": 23.1, "final_year_of_manufacture": null, "raw": ["015737", "000250", "0", "2008/Feb/29 10:31", "Fondital SpA", "Fondital", "Tahiti Condensing KC 24 Line Tech", "", "", "2006", "current", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "23.1", "23.1", "", "", "87.9", "79.3", "", "55.7", "", "2", "", "", "104", "1", "2", "155", "10", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "96.5", "", "", "", "", "94.9"]} -{"pcdb_id": 15738, "brand_name": "Fondital", "model_name": "Tahiti Condensing KC 24 Line Tech", "model_qualifier": "", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 56.4, "output_kw_max": 23.1, "final_year_of_manufacture": null, "raw": ["015738", "000250", "0", "2008/Feb/29 10:31", "Fondital SpA", "Fondital", "Tahiti Condensing KC 24 Line Tech", "", "", "2006", "current", "2", "2", "1", "2", "0", "", "", "2", "3", "2", "23.1", "23.1", "", "", "88.9", "80.3", "", "56.4", "", "2", "1", "", "104", "1", "2", "155", "10", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.8", "98.6", "", "", "", "", "97.0"]} -{"pcdb_id": 15740, "brand_name": "Biasi", "model_name": "Riva Advance HE", "model_qualifier": "M110B.24SM/C", "winter_efficiency_pct": 89.5, "summer_efficiency_pct": 80.9, "comparative_hot_water_efficiency_pct": 56.9, "output_kw_max": 25.1, "final_year_of_manufacture": null, "raw": ["015740", "000208", "0", "2008/Jun/26 09:42", "Biasi SpA", "Biasi", "Riva Advance HE", "M110B.24SM/C", "47-583-11", "2007", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "5.8", "25.1", "", "", "89.5", "80.9", "", "56.9", "", "2", "1", "", "104", "1", "2", "108", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.1", "100.1", "", "", "", "", "98.2"]} -{"pcdb_id": 15741, "brand_name": "Biasi", "model_name": "Riva Advance HE", "model_qualifier": "M110B.24SM/C", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 56.2, "output_kw_max": 25.1, "final_year_of_manufacture": null, "raw": ["015741", "000208", "0", "2013/Feb/27 12:39", "Biasi SpA", "Biasi", "Riva Advance HE", "M110B.24SM/C", "47-583-11", "2007", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "25.1", "25.1", "", "", "88.5", "79.9", "", "56.2", "", "2", "", "", "104", "1", "2", "108", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.1", "97.9", "", "", "", "", "96.1"]} -{"pcdb_id": 15742, "brand_name": "Biasi", "model_name": "Riva Advance HE", "model_qualifier": "M110B.32SM/C", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 56.5, "output_kw_max": 33.1, "final_year_of_manufacture": null, "raw": ["015742", "000208", "0", "2008/Jun/26 09:42", "Biasi SpA", "Biasi", "Riva Advance HE", "M110B.32SM/C", "47-583-12", "2007", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "33.1", "33.1", "", "", "88.9", "80.3", "", "56.5", "", "2", "1", "", "104", "1", "2", "125", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.7", "98.9", "", "", "", "", "97.2"]} -{"pcdb_id": 15743, "brand_name": "Biasi", "model_name": "Riva Advance HE", "model_qualifier": "M110B.32SM/C", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 55.8, "output_kw_max": 33.1, "final_year_of_manufacture": null, "raw": ["015743", "000208", "0", "2013/Feb/27 12:41", "Biasi SpA", "Biasi", "Riva Advance HE", "M110B.32SM/C", "47-583-12", "2007", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "33.1", "33.1", "", "", "88.0", "79.4", "", "55.8", "", "2", "", "", "104", "1", "2", "125", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "96.8", "", "", "", "", "95.1"]} -{"pcdb_id": 15744, "brand_name": "Biasi", "model_name": "Garda Plus HE", "model_qualifier": "M110B.24SM/E", "winter_efficiency_pct": 89.5, "summer_efficiency_pct": 80.9, "comparative_hot_water_efficiency_pct": 56.9, "output_kw_max": 25.1, "final_year_of_manufacture": null, "raw": ["015744", "000208", "0", "2008/Jun/26 09:42", "Biasi SpA", "Biasi", "Garda Plus HE", "M110B.24SM/E", "47-583-13", "2007", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "5.8", "25.1", "", "", "89.5", "80.9", "", "56.9", "", "2", "1", "", "104", "1", "2", "108", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.1", "100.1", "", "", "", "", "98.2"]} -{"pcdb_id": 15745, "brand_name": "Biasi", "model_name": "Garda Plus HE", "model_qualifier": "M110B.24SM/E", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 56.2, "output_kw_max": 25.1, "final_year_of_manufacture": null, "raw": ["015745", "000208", "0", "2008/Jun/26 09:41", "Biasi SpA", "Biasi", "Garda Plus HE", "M110B.24SM/E", "47-583-13", "2007", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "5.8", "25.1", "", "", "88.5", "79.9", "", "56.2", "", "2", "", "", "104", "1", "2", "108", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.1", "97.9", "", "", "", "", "96.1"]} -{"pcdb_id": 15746, "brand_name": "Biasi", "model_name": "Garda Plus HE", "model_qualifier": "M110B.32SM/E", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 56.5, "output_kw_max": 33.1, "final_year_of_manufacture": null, "raw": ["015746", "000208", "0", "2008/Jun/26 09:42", "Biasi SpA", "Biasi", "Garda Plus HE", "M110B.32SM/E", "47-583-14", "2007", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "8.2", "33.1", "", "", "88.9", "80.3", "", "56.5", "", "2", "1", "", "104", "1", "2", "125", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.7", "98.9", "", "", "", "", "97.2"]} -{"pcdb_id": 15747, "brand_name": "Biasi", "model_name": "Garda Plus HE", "model_qualifier": "M110B.32SM/E", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 55.8, "output_kw_max": 33.1, "final_year_of_manufacture": null, "raw": ["015747", "000208", "0", "2008/Jun/26 09:41", "Biasi SpA", "Biasi", "Garda Plus HE", "M110B.32SM/E", "47-583-14", "2007", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "8.2", "33.1", "", "", "88.0", "79.4", "", "55.8", "", "2", "", "", "104", "1", "2", "125", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "96.8", "", "", "", "", "95.1"]} -{"pcdb_id": 15748, "brand_name": "British Gas", "model_name": "330+", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 30.0, "final_year_of_manufacture": null, "raw": ["015748", "000207", "0", "2012/Mar/27 10:12", "Vaillant Group UK", "British Gas", "330+", "", "41-019-11", "2008", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "30.00", "30.00", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "60", "6", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.8", "96.4", "", "", "", "", "95.0"]} -{"pcdb_id": 15749, "brand_name": "Scottish Gas", "model_name": "330+", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 30.0, "final_year_of_manufacture": null, "raw": ["015749", "000207", "0", "2012/Mar/27 10:12", "Vaillant Group UK", "Scottish Gas", "330+", "", "", "2008", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "30.00", "30.00", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "60", "6", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.8", "96.4", "", "", "", "", "95.0"]} -{"pcdb_id": 15751, "brand_name": "Potterton", "model_name": "Gold", "model_qualifier": "24 HE A", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 56.1, "output_kw_max": 20.5, "final_year_of_manufacture": 2015, "raw": ["015751", "000005", "0", "2015/Aug/06 12:53", "Baxi Heating UK", "Potterton", "Gold", "24 HE A", "GC No. 47-393-18", "2008", "2015", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "20.5", "20.5", "", "", "88.4", "79.8", "", "56.1", "", "2", "", "", "104", "1", "2", "155", "5", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "90.0", "96.9", "", "", "", "", "95.6"]} -{"pcdb_id": 15752, "brand_name": "Potterton", "model_name": "Gold", "model_qualifier": "28 HE A", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 56.1, "output_kw_max": 24.7, "final_year_of_manufacture": 2015, "raw": ["015752", "000005", "0", "2015/Aug/06 12:54", "Baxi Heating UK", "Potterton", "Gold", "28 HE A", "GC No. 47-393-19", "2008", "2015", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.7", "24.7", "", "", "88.4", "79.8", "", "56.1", "", "2", "", "", "104", "1", "2", "155", "5", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "90.0", "96.9", "", "", "", "", "95.6"]} -{"pcdb_id": 15753, "brand_name": "Potterton", "model_name": "Gold", "model_qualifier": "33 HE A", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 56.0, "output_kw_max": 28.9, "final_year_of_manufacture": 2015, "raw": ["015753", "000005", "0", "2015/Aug/06 12:54", "Baxi Heating UK", "Potterton", "Gold", "33 HE A", "GC No 47-393-20", "2008", "2015", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28.9", "28.9", "", "", "88.3", "79.7", "", "56.0", "", "2", "", "", "104", "1", "2", "160", "5", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "90.0", "96.7", "", "", "", "", "95.4"]} -{"pcdb_id": 15754, "brand_name": "Potterton", "model_name": "Promax System", "model_qualifier": "12 HE Plus A", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 12.4, "final_year_of_manufacture": 2015, "raw": ["015754", "000005", "0", "2015/Aug/06 12:55", "Baxi Heating UK", "Potterton", "Promax System", "12 HE Plus A", "GC No. 41-591-99", "2008", "2015", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "12.4", "12.4", "", "", "88.3", "79.3", "", "57.9", "", "2", "", "", "102", "1", "2", "145", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.9", "96.7", "", "", "", "", "95.4"]} -{"pcdb_id": 15755, "brand_name": "Potterton", "model_name": "Promax System", "model_qualifier": "15 HE Plus A", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 15.4, "final_year_of_manufacture": 2015, "raw": ["015755", "000005", "0", "2015/Aug/06 12:56", "Baxi Heating UK", "Potterton", "Promax System", "15 HE Plus A", "GC No. 41-592-01", "2008", "2015", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "15.4", "15.4", "", "", "88.3", "79.3", "", "57.9", "", "2", "", "", "102", "1", "2", "130", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.9", "96.8", "", "", "", "", "95.5"]} -{"pcdb_id": 15756, "brand_name": "Potterton", "model_name": "Promax System", "model_qualifier": "18 HE Plus A", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 18.5, "final_year_of_manufacture": 2015, "raw": ["015756", "000005", "0", "2015/Aug/06 12:56", "Baxi Heating UK", "Potterton", "Promax System", "18 HE Plus A", "GC NO. 41-592-02", "2008", "2015", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18.5", "18.5", "", "", "88.3", "79.3", "", "58.0", "", "2", "", "", "102", "1", "2", "140", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.9", "96.9", "", "", "", "", "95.5"]} -{"pcdb_id": 15757, "brand_name": "Potterton", "model_name": "Promax System", "model_qualifier": "24 HE Plus A", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 24.7, "final_year_of_manufacture": 2015, "raw": ["015757", "000005", "0", "2015/Aug/06 12:57", "Baxi Heating UK", "Potterton", "Promax System", "24 HE Plus A", "GC No. 41-592-03", "2008", "2015", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24.7", "24.7", "", "", "88.3", "79.3", "", "58.0", "", "2", "", "", "102", "1", "2", "150", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.9", "96.9", "", "", "", "", "95.5"]} -{"pcdb_id": 15758, "brand_name": "Potterton", "model_name": "Promax System", "model_qualifier": "32 HE Plus A", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 32.8, "final_year_of_manufacture": 2015, "raw": ["015758", "000005", "0", "2015/Aug/06 12:57", "Baxi Heating UK", "Potterton", "Promax System", "32 HE Plus A", "GC No. 41-592-04", "2008", "2015", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "32.8", "32.8", "", "", "88.3", "79.3", "", "57.9", "", "2", "", "", "102", "1", "2", "160", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.9", "96.7", "", "", "", "", "95.4"]} -{"pcdb_id": 15759, "brand_name": "Potterton", "model_name": "Performa", "model_qualifier": "9 SL HE", "winter_efficiency_pct": 84.0, "summer_efficiency_pct": 76.4, "comparative_hot_water_efficiency_pct": 55.8, "output_kw_max": 8.82, "final_year_of_manufacture": 2011, "raw": ["015759", "000005", "0", "2013/May/07 10:34", "Baxi Heating UK", "Potterton", "Performa", "9 SL HE", "GC No. 41-592-05", "2008", "2011", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "8.82", "8.82", "", "", "84.0", "76.4", "", "55.8", "", "2", "", "", "101", "1", "1", "80", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "86.3", "90.9", "", "", "", "", "90.0"]} -{"pcdb_id": 15760, "brand_name": "Potterton", "model_name": "Performa", "model_qualifier": "12 SL HE", "winter_efficiency_pct": 84.2, "summer_efficiency_pct": 76.6, "comparative_hot_water_efficiency_pct": 55.9, "output_kw_max": 11.78, "final_year_of_manufacture": 2011, "raw": ["015760", "000005", "0", "2013/May/07 10:35", "Baxi Heating UK", "Potterton", "Performa", "12 SL HE", "GC No. 41-592-06", "2008", "2011", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "11.78", "11.78", "", "", "84.2", "76.6", "", "55.9", "", "2", "", "", "101", "1", "1", "80", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "86.5", "91.3", "", "", "", "", "90.4"]} -{"pcdb_id": 15761, "brand_name": "Potterton", "model_name": "Performa", "model_qualifier": "15 SL HE", "winter_efficiency_pct": 84.0, "summer_efficiency_pct": 76.4, "comparative_hot_water_efficiency_pct": 55.8, "output_kw_max": 14.76, "final_year_of_manufacture": 2011, "raw": ["015761", "000005", "0", "2013/May/07 10:35", "Baxi Heating UK", "Potterton", "Performa", "15 SL HE", "GC No. 41-592-07", "2008", "2011", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "14.76", "14.76", "", "", "84.0", "76.4", "", "55.8", "", "2", "", "", "101", "1", "1", "80", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "86.7", "90.7", "", "", "", "", "90.0"]} -{"pcdb_id": 15762, "brand_name": "Potterton", "model_name": "Performa", "model_qualifier": "18 SL HE", "winter_efficiency_pct": 84.0, "summer_efficiency_pct": 76.4, "comparative_hot_water_efficiency_pct": 55.8, "output_kw_max": 17.72, "final_year_of_manufacture": 2011, "raw": ["015762", "000005", "0", "2013/May/07 10:35", "Baxi Heating UK", "Potterton", "Performa", "18 SL HE", "GC No. 41-592-08", "2008", "2011", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "17.72", "17.72", "", "", "84.0", "76.4", "", "55.8", "", "2", "", "", "101", "1", "1", "80", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "86.8", "90.6", "", "", "", "", "89.9"]} -{"pcdb_id": 15763, "brand_name": "Potterton", "model_name": "Performa", "model_qualifier": "21 SL HE", "winter_efficiency_pct": 84.0, "summer_efficiency_pct": 76.4, "comparative_hot_water_efficiency_pct": 55.8, "output_kw_max": 20.68, "final_year_of_manufacture": 2011, "raw": ["015763", "000005", "0", "2013/May/07 10:35", "Baxi Heating UK", "Potterton", "Performa", "21 SL HE", "GC No. 41-592-09", "2008", "2011", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "20.68", "20.68", "", "", "84.0", "76.4", "", "55.8", "", "2", "", "", "101", "1", "1", "80", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "86.8", "90.7", "", "", "", "", "90.0"]} -{"pcdb_id": 15764, "brand_name": "Potterton", "model_name": "Performa", "model_qualifier": "24 SL HE", "winter_efficiency_pct": 84.0, "summer_efficiency_pct": 76.4, "comparative_hot_water_efficiency_pct": 55.8, "output_kw_max": 23.63, "final_year_of_manufacture": 2011, "raw": ["015764", "000005", "0", "2013/May/07 10:35", "Baxi Heating UK", "Potterton", "Performa", "24 SL HE", "GC No. 41-592-10", "2008", "2011", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "23.63", "23.63", "", "", "84.0", "76.4", "", "55.8", "", "2", "", "", "101", "1", "1", "80", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "86.8", "90.6", "", "", "", "", "89.9"]} -{"pcdb_id": 15766, "brand_name": "Glow-worm", "model_name": "Flexicom 35cx", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 56.2, "output_kw_max": 30.0, "final_year_of_manufacture": null, "raw": ["015766", "000207", "0", "2010/Oct/22 10:40", "Vaillant Group", "Glow-worm", "Flexicom 35cx", "", "GC 47-047-35", "2008", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "30.0", "30.0", "", "", "88.5", "79.9", "", "56.2", "", "2", "", "", "104", "1", "2", "180", "6", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0085", "", "", "", "", "", "", "", "", "88.1", "98.0", "", "", "", "", "96.1"]} -{"pcdb_id": 15767, "brand_name": "Glow-worm", "model_name": "Flexicom 35hx", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 35.0, "final_year_of_manufacture": null, "raw": ["015767", "000207", "0", "2012/Mar/27 10:12", "Vaillant Group", "Glow-worm", "Flexicom 35hx", "", "GC 41-315-68", "2008", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "35.0", "35.0", "", "", "88.5", "79.5", "", "58.1", "", "2", "", "", "102", "1", "2", "60", "6", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0085", "", "", "", "", "", "", "", "", "88.1", "98.0", "", "", "", "", "96.1"]} -{"pcdb_id": 15768, "brand_name": "Sime", "model_name": "Murelle HE", "model_qualifier": "12 System", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 11.7, "final_year_of_manufacture": 2018, "raw": ["015768", "000213", "0", "2018/Mar/05 16:39", "Fonderie Sime S.p.A.", "Sime", "Murelle HE", "12 System", "", "2008", "2018", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "11.7", "11.7", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "110", "8", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.2", "96.6", "", "", "", "", "95.0"]} -{"pcdb_id": 15769, "brand_name": "Sime", "model_name": "Murelle HE", "model_qualifier": "12 System", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 11.7, "final_year_of_manufacture": 2018, "raw": ["015769", "000213", "0", "2018/Mar/05 16:39", "Fonderie Sime S.p.A.", "Sime", "Murelle HE", "12 System", "", "2008", "2018", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "11.7", "11.7", "", "", "89.0", "80.0", "", "58.4", "", "2", "1", "", "102", "1", "2", "110", "8", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.2", "98.7", "", "", "", "", "97.1"]} -{"pcdb_id": 15770, "brand_name": "Sime", "model_name": "Murelle HE", "model_qualifier": "20 System", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 19.0, "final_year_of_manufacture": 2018, "raw": ["015770", "000213", "0", "2018/Mar/05 16:41", "Fonderie Sime S.p.A.", "Sime", "Murelle HE", "20 System", "", "2008", "2018", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "19.0", "19.0", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "120", "8", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.2", "96.8", "", "", "", "", "95.1"]} -{"pcdb_id": 15771, "brand_name": "Sime", "model_name": "Murelle HE", "model_qualifier": "20 System", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 19.0, "final_year_of_manufacture": 2018, "raw": ["015771", "000213", "0", "2018/Mar/05 16:41", "Fonderie Sime S.p.A.", "Sime", "Murelle HE", "20 System", "", "2008", "2018", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "19.0", "19.0", "", "", "89.0", "80.0", "", "58.5", "", "2", "1", "", "102", "1", "2", "120", "8", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.2", "98.9", "", "", "", "", "97.3"]} -{"pcdb_id": 15772, "brand_name": "Sime", "model_name": "Murelle HE", "model_qualifier": "25 System", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 23.9, "final_year_of_manufacture": 2018, "raw": ["015772", "000213", "0", "2018/Mar/05 16:44", "Fonderie Sime S.p.A.", "Sime", "Murelle HE", "25 System", "", "2008", "2018", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "23.9", "23.9", "", "", "88.2", "79.2", "", "57.9", "", "2", "", "", "102", "1", "2", "125", "8", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.5", "97.1", "", "", "", "", "95.5"]} -{"pcdb_id": 15773, "brand_name": "Sime", "model_name": "Murelle HE", "model_qualifier": "25 System", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 23.9, "final_year_of_manufacture": 2018, "raw": ["015773", "000213", "0", "2018/Mar/05 16:45", "Fonderie Sime S.p.A.", "Sime", "Murelle HE", "25 System", "", "2008", "2018", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "23.9", "23.9", "", "", "89.2", "80.2", "", "58.6", "", "2", "1", "", "102", "1", "2", "125", "8", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.4", "99.3", "", "", "", "", "97.6"]} -{"pcdb_id": 15774, "brand_name": "Sime", "model_name": "Murelle HE", "model_qualifier": "30 System", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 28.9, "final_year_of_manufacture": 2018, "raw": ["015774", "000213", "0", "2018/Mar/05 16:52", "Fonderie Sime S.p.A.", "Sime", "Murelle HE", "30 System", "", "2008", "2018", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "28.9", "28.9", "", "", "88.2", "79.2", "", "57.9", "", "2", "", "", "102", "1", "2", "130", "8", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.7", "97.0", "", "", "", "", "95.4"]} -{"pcdb_id": 15775, "brand_name": "Sime", "model_name": "Murelle HE", "model_qualifier": "30 System", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 28.9, "final_year_of_manufacture": 2018, "raw": ["015775", "000213", "0", "2018/Mar/05 16:53", "Fonderie Sime S.p.A.", "Sime", "Murelle HE", "30 System", "", "2008", "2018", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "28.9", "28.9", "", "", "89.2", "80.2", "", "58.6", "", "2", "1", "", "102", "1", "2", "130", "8", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.6", "99.2", "", "", "", "", "97.6"]} -{"pcdb_id": 15776, "brand_name": "Sime", "model_name": "Murelle HE", "model_qualifier": "35 System", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 34.1, "final_year_of_manufacture": 2018, "raw": ["015776", "000213", "0", "2018/Mar/05 16:45", "Fonderie Sime S.p.A.", "Sime", "Murelle HE", "35 System", "", "2008", "2018", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "34.1", "34.1", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "140", "8", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.5", "96.2", "", "", "", "", "94.9"]} -{"pcdb_id": 15777, "brand_name": "Sime", "model_name": "Murelle HE", "model_qualifier": "35 System", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 34.1, "final_year_of_manufacture": 2018, "raw": ["015777", "000213", "0", "2018/Mar/05 16:47", "Fonderie Sime S.p.A.", "Sime", "Murelle HE", "35 System", "", "2008", "2018", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "34.1", "34.1", "", "", "89.0", "80.0", "", "58.4", "", "2", "1", "", "102", "1", "2", "140", "8", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "91.5", "98.4", "", "", "", "", "97.1"]} -{"pcdb_id": 15778, "brand_name": "Sime", "model_name": "Murelle HE", "model_qualifier": "25/55 BF", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 80.7, "comparative_hot_water_efficiency_pct": 46.6, "output_kw_max": 23.9, "final_year_of_manufacture": 2018, "raw": ["015778", "000213", "0", "2024/Jan/31 10:17", "Fonderie Sime S.p.A.", "Sime", "Murelle HE", "25/55 BF", "", "2008", "2018", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "23.9", "23.9", "", "", "88.0", "80.7", "", "46.6", "", "2", "", "", "106", "1", "2", "115", "8", "2", "1", "0", "48", "0", "20", "5", "60", "275", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "96.6", "", "", "", "", "95.0"]} -{"pcdb_id": 15779, "brand_name": "Sime", "model_name": "Murelle HE", "model_qualifier": "25/55 BF", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 81.7, "comparative_hot_water_efficiency_pct": 47.2, "output_kw_max": 23.9, "final_year_of_manufacture": 2018, "raw": ["015779", "000213", "0", "2024/Jan/31 10:17", "Fonderie Sime S.p.A.", "Sime", "Murelle HE", "25/55 BF", "", "2008", "2018", "2", "2", "1", "2", "0", "", "", "2", "3", "2", "23.9", "23.9", "", "", "89.0", "81.7", "", "47.2", "", "2", "1", "", "106", "1", "2", "115", "8", "2", "1", "0", "48", "0", "20", "5", "60", "275", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.3", "98.7", "", "", "", "", "97.1"]} -{"pcdb_id": 15780, "brand_name": "Sime", "model_name": "Murelle HE", "model_qualifier": "30/55 BF", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 46.7, "output_kw_max": 28.9, "final_year_of_manufacture": 2018, "raw": ["015780", "000213", "0", "2024/Jan/31 10:17", "Fonderie Sime S.p.A.", "Sime", "Murelle HE", "30/55 BF", "", "2008", "2018", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "28.9", "28.9", "", "", "88.1", "80.8", "", "46.7", "", "2", "", "", "106", "1", "2", "115", "8", "2", "1", "0", "48", "0", "20", "5", "60", "275", "0", "", "", "", "", "", "", "", "", "", "0", "0", "", "0005", "", "", "", "", "", "", "", "", "88.7", "96.8", "", "", "", "", "95.2"]} -{"pcdb_id": 15781, "brand_name": "Sime", "model_name": "Murelle HE", "model_qualifier": "30/55 BF", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 81.8, "comparative_hot_water_efficiency_pct": 47.2, "output_kw_max": 28.9, "final_year_of_manufacture": 2018, "raw": ["015781", "000213", "0", "2024/Jan/31 10:17", "Fonderie Sime S.p.A.", "Sime", "Murelle HE", "30/55 BF", "", "2008", "2018", "2", "2", "1", "2", "0", "", "", "2", "3", "2", "28.9", "28.9", "", "", "89.1", "81.8", "", "47.2", "", "2", "1", "", "106", "1", "2", "115", "8", "1", "1", "0", "48", "0", "20", "5", "60", "275", "0", "", "", "", "", "", "", "", "", "", "0", "0", "", "0005", "", "", "", "", "", "", "", "", "90.6", "98.9", "", "", "", "", "97.3"]} -{"pcdb_id": 15782, "brand_name": "Heatline", "model_name": "Vizo Plus", "model_qualifier": "24", "winter_efficiency_pct": 87.8, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 55.7, "output_kw_max": 19.5, "final_year_of_manufacture": 2009, "raw": ["015782", "000215", "0", "2011/Aug/31 10:38", "Turk Demir Dokum Fab AS", "Heatline", "Vizo Plus", "24", "GC No. 47-157-14", "2007", "2009", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "19.5", "19.5", "", "", "87.8", "79.2", "", "55.7", "", "2", "", "", "104", "1", "2", "175", "10", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "96.4", "", "", "", "", "94.8"]} -{"pcdb_id": 15783, "brand_name": "Firebird", "model_name": "Enviromax Combi C20", "model_qualifier": "", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 82.6, "comparative_hot_water_efficiency_pct": 50.6, "output_kw_max": 20.0, "final_year_of_manufacture": 2010, "raw": ["015783", "000047", "0", "2024/Jan/31 10:17", "Firebird Boilers", "Firebird", "Enviromax Combi C20", "", "", "2007", "2010", "4", "1", "1", "2", "0", "", "", "2", "3", "1", "15", "20", "", "", "88.7", "82.6", "", "50.6", "", "2", "", "", "203", "1", "1", "38", "0", "2", "1", "0", "40", "0", "25", "1", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.7", "96.1", "", "", "", "", "95.3"]} -{"pcdb_id": 15784, "brand_name": "Firebird", "model_name": "Enviromax Combipac C20", "model_qualifier": "", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 82.6, "comparative_hot_water_efficiency_pct": 50.6, "output_kw_max": 20.0, "final_year_of_manufacture": 2010, "raw": ["015784", "000047", "0", "2024/Jan/31 10:17", "Firebird Boilers", "Firebird", "Enviromax Combipac C20", "", "", "2007", "2010", "4", "1", "2", "2", "0", "", "", "2", "1", "1", "15", "20", "", "", "88.7", "82.6", "", "50.6", "", "2", "", "", "203", "1", "1", "38", "0", "2", "1", "0", "40", "0", "25", "1", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.7", "96.1", "", "", "", "", "95.3"]} -{"pcdb_id": 15785, "brand_name": "Firebird", "model_name": "Enviromax System C20", "model_qualifier": "", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 80.9, "comparative_hot_water_efficiency_pct": 59.1, "output_kw_max": 20.0, "final_year_of_manufacture": 2010, "raw": ["015785", "000047", "0", "2012/Mar/27 10:12", "Firebird Boilers", "Firebird", "Enviromax System C20", "", "", "2007", "2010", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "15", "20", "", "", "88.7", "80.9", "", "59.1", "", "2", "", "", "201", "1", "1", "38", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.7", "96.1", "", "", "", "", "95.3"]} -{"pcdb_id": 15786, "brand_name": "Firebird", "model_name": "Enviromax Systempac C20", "model_qualifier": "", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 80.9, "comparative_hot_water_efficiency_pct": 59.1, "output_kw_max": 20.0, "final_year_of_manufacture": 2010, "raw": ["015786", "000047", "0", "2012/Mar/27 10:12", "Firebird Boilers", "Firebird", "Enviromax Systempac C20", "", "", "2007", "2010", "4", "1", "2", "1", "0", "", "", "2", "1", "1", "15", "20", "", "", "88.7", "80.9", "", "59.1", "", "2", "", "", "201", "1", "1", "38", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.7", "96.1", "", "", "", "", "95.3"]} -{"pcdb_id": 15787, "brand_name": "Firebird", "model_name": "Enviromax Popular C20", "model_qualifier": "", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 80.9, "comparative_hot_water_efficiency_pct": 59.1, "output_kw_max": 20.0, "final_year_of_manufacture": 2010, "raw": ["015787", "000047", "0", "2012/Mar/27 10:12", "Firebird Boilers", "Firebird", "Enviromax Popular C20", "", "", "2007", "2010", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "15", "20", "", "", "88.7", "80.9", "", "59.1", "", "2", "", "", "201", "1", "1", "38", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.7", "96.1", "", "", "", "", "95.3"]} -{"pcdb_id": 15788, "brand_name": "Firebird", "model_name": "Enviromax Heatpac C20", "model_qualifier": "", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 80.9, "comparative_hot_water_efficiency_pct": 59.1, "output_kw_max": 20.0, "final_year_of_manufacture": 2010, "raw": ["015788", "000047", "0", "2012/Mar/27 10:12", "Firebird Boilers", "Firebird", "Enviromax Heatpac C20", "", "", "2007", "2010", "4", "1", "2", "1", "0", "", "", "2", "1", "1", "15", "20", "", "", "88.7", "80.9", "", "59.1", "", "2", "", "", "201", "1", "1", "38", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.7", "96.1", "", "", "", "", "95.3"]} -{"pcdb_id": 15789, "brand_name": "Firebird", "model_name": "Enviromax Kitchen C20", "model_qualifier": "", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 80.9, "comparative_hot_water_efficiency_pct": 59.1, "output_kw_max": 20.0, "final_year_of_manufacture": 2010, "raw": ["015789", "000047", "0", "2012/Mar/27 10:12", "Firebird Boilers", "Firebird", "Enviromax Kitchen C20", "", "", "2007", "2010", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "15", "20", "", "", "88.7", "80.9", "", "59.1", "", "2", "", "", "201", "1", "2", "38", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "91.7", "96.1", "", "", "", "", "95.3"]} -{"pcdb_id": 15790, "brand_name": "Firebird", "model_name": "Enviromax Utility C20", "model_qualifier": "", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 80.9, "comparative_hot_water_efficiency_pct": 59.1, "output_kw_max": 20.0, "final_year_of_manufacture": 2010, "raw": ["015790", "000047", "0", "2012/Mar/27 10:12", "Firebird Boilers", "Firebird", "Enviromax Utility C20", "", "", "2007", "2010", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "15", "20", "", "", "88.7", "80.9", "", "59.1", "", "2", "", "", "201", "1", "1", "38", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.7", "96.1", "", "", "", "", "95.3"]} -{"pcdb_id": 15791, "brand_name": "Firebird", "model_name": "Enviromax Combi C26", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 82.7, "comparative_hot_water_efficiency_pct": 50.7, "output_kw_max": 26.0, "final_year_of_manufacture": 2010, "raw": ["015791", "000047", "0", "2024/Jan/31 10:17", "Firebird Boilers", "Firebird", "Enviromax Combi C26", "", "", "2007", "2010", "4", "1", "1", "2", "0", "", "", "2", "3", "1", "15", "26", "", "", "88.8", "82.7", "", "50.7", "", "2", "", "", "203", "1", "1", "38", "0", "2", "1", "0", "40", "0", "25", "1", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.6", "96.6", "", "", "", "", "95.7"]} -{"pcdb_id": 15792, "brand_name": "Firebird", "model_name": "Enviromax Combipac C26", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 82.7, "comparative_hot_water_efficiency_pct": 50.7, "output_kw_max": 26.0, "final_year_of_manufacture": 2010, "raw": ["015792", "000047", "0", "2024/Jan/31 10:17", "Firebird Boilers", "Firebird", "Enviromax Combipac C26", "", "", "2007", "2010", "4", "1", "2", "2", "0", "", "", "2", "1", "1", "15", "26", "", "", "88.8", "82.7", "", "50.7", "", "2", "", "", "203", "1", "1", "38", "0", "2", "1", "0", "40", "0", "25", "1", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "0", "", "0003", "", "", "", "", "", "", "", "", "91.6", "96.6", "", "", "", "", "95.7"]} -{"pcdb_id": 15793, "brand_name": "Firebird", "model_name": "Enviromax System C26", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 59.2, "output_kw_max": 26.0, "final_year_of_manufacture": 2010, "raw": ["015793", "000047", "0", "2012/Mar/27 10:12", "Firebird Boilers", "Firebird", "Enviromax System C26", "", "", "2007", "2010", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "15", "26", "", "", "88.8", "81.0", "", "59.2", "", "2", "", "", "201", "1", "1", "38", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.6", "96.6", "", "", "", "", "95.7"]} -{"pcdb_id": 15794, "brand_name": "Firebird", "model_name": "Enviromax Systempac C26", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 59.2, "output_kw_max": 26.0, "final_year_of_manufacture": 2010, "raw": ["015794", "000047", "0", "2012/Mar/27 10:12", "Firebird Boilers", "Firebird", "Enviromax Systempac C26", "", "", "2007", "2010", "4", "1", "2", "1", "0", "", "", "2", "1", "1", "15", "26", "", "", "88.8", "81.0", "", "59.2", "", "2", "", "", "201", "1", "1", "38", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.6", "96.6", "", "", "", "", "95.7"]} -{"pcdb_id": 15795, "brand_name": "Firebird", "model_name": "Enviromax Popular C26", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 59.2, "output_kw_max": 26.0, "final_year_of_manufacture": 2010, "raw": ["015795", "000047", "0", "2012/Mar/27 10:12", "Firebird Boilers", "Firebird", "Enviromax Popular C26", "", "", "2007", "2010", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "15", "26", "", "", "88.8", "81.0", "", "59.2", "", "2", "", "", "201", "1", "1", "38", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.6", "96.6", "", "", "", "", "95.7"]} -{"pcdb_id": 15796, "brand_name": "Firebird", "model_name": "Enviromax Heatpac C26", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 59.2, "output_kw_max": 26.0, "final_year_of_manufacture": 2010, "raw": ["015796", "000047", "0", "2012/Mar/27 10:12", "Firebird Boilers", "Firebird", "Enviromax Heatpac C26", "", "", "2007", "2010", "4", "1", "2", "1", "0", "", "", "2", "1", "1", "15", "26", "", "", "88.8", "81.0", "", "59.2", "", "2", "", "", "201", "1", "1", "38", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.6", "96.6", "", "", "", "", "95.7"]} -{"pcdb_id": 15797, "brand_name": "Firebird", "model_name": "Enviromax Kitchen C26", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 59.2, "output_kw_max": 26.0, "final_year_of_manufacture": 2010, "raw": ["015797", "000047", "0", "2012/Mar/27 10:12", "Firebird Boilers", "Firebird", "Enviromax Kitchen C26", "", "", "2007", "2010", "4", "1", "1", "1", "0", "", "", "2", "2", "1", "15", "26", "", "", "88.8", "81.0", "", "59.2", "", "2", "", "", "201", "1", "1", "38", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.6", "96.6", "", "", "", "", "95.7"]} -{"pcdb_id": 15798, "brand_name": "Firebird", "model_name": "Enviromax Utility C26", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 59.2, "output_kw_max": 26.0, "final_year_of_manufacture": 2010, "raw": ["015798", "000047", "0", "2012/Mar/27 10:12", "Firebird Boilers", "Firebird", "Enviromax Utility C26", "", "", "2007", "2010", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "15", "26", "", "", "88.8", "81.0", "", "59.2", "", "2", "", "", "201", "1", "1", "8", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.6", "96.6", "", "", "", "", "95.7"]} -{"pcdb_id": 15799, "brand_name": "Firebird", "model_name": "Enviromax Combi C35", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 81.9, "comparative_hot_water_efficiency_pct": 50.1, "output_kw_max": 35.0, "final_year_of_manufacture": 2010, "raw": ["015799", "000047", "0", "2024/Jan/31 10:17", "Firebird Boilers", "Firebird", "Enviromax Combi C35", "", "", "2007", "2010", "4", "1", "1", "2", "0", "", "", "2", "3", "1", "26", "35", "", "", "88.0", "81.9", "", "50.1", "", "2", "", "", "203", "1", "1", "38", "0", "2", "1", "0", "40", "0", "25", "1", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "0", "", "0003", "", "", "", "", "", "", "", "", "91.7", "94.4", "", "", "", "", "93.9"]} -{"pcdb_id": 15800, "brand_name": "Firebird", "model_name": "Enviromax Combipac C35", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 81.9, "comparative_hot_water_efficiency_pct": 50.1, "output_kw_max": 35.0, "final_year_of_manufacture": 2010, "raw": ["015800", "000047", "0", "2024/Jan/31 10:17", "Firebird Boilers", "Firebird", "Enviromax Combipac C35", "", "", "2007", "2010", "4", "1", "2", "2", "0", "", "", "2", "1", "1", "26", "35", "", "", "88.0", "81.9", "", "50.1", "", "2", "", "", "203", "1", "1", "38", "0", "2", "1", "0", "40", "0", "25", "1", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "0", "", "0003", "", "", "", "", "", "", "", "", "91.7", "94.4", "", "", "", "", "93.9"]} -{"pcdb_id": 15801, "brand_name": "Firebird", "model_name": "Enviromax System C35", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 35.0, "final_year_of_manufacture": 2010, "raw": ["015801", "000047", "0", "2012/Mar/27 10:12", "Firebird Boilers", "Firebird", "Enviromax System C35", "", "", "2007", "2010", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "26", "35", "", "", "88.0", "80.2", "", "58.6", "", "2", "", "", "201", "1", "1", "38", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.7", "94.4", "", "", "", "", "93.9"]} -{"pcdb_id": 15802, "brand_name": "Firebird", "model_name": "Enviromax Systempac C35", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 35.0, "final_year_of_manufacture": 2010, "raw": ["015802", "000047", "0", "2012/Mar/27 10:12", "Firebird Boilers", "Firebird", "Enviromax Systempac C35", "", "", "2007", "2010", "4", "1", "2", "1", "0", "", "", "2", "1", "1", "26", "35", "", "", "88.0", "80.2", "", "58.6", "", "2", "", "", "201", "1", "1", "38", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.7", "94.4", "", "", "", "", "93.9"]} -{"pcdb_id": 15803, "brand_name": "Firebird", "model_name": "Enviromax Popular C35", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 35.0, "final_year_of_manufacture": 2010, "raw": ["015803", "000047", "0", "2012/Mar/27 10:12", "Firebird Boilers", "Firebird", "Enviromax Popular C35", "", "", "2007", "2010", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "26", "35", "", "", "88.0", "80.2", "", "58.6", "", "2", "", "", "201", "1", "1", "38", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.7", "94.4", "", "", "", "", "93.9"]} -{"pcdb_id": 15804, "brand_name": "Firebird", "model_name": "Enviromax Heatpac C35", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 35.0, "final_year_of_manufacture": 2008, "raw": ["015804", "000047", "0", "2012/Apr/17 15:10", "Firebird Boilers", "Firebird", "Enviromax Heatpac C35", "", "", "2007", "2008", "4", "1", "2", "1", "0", "", "", "2", "1", "1", "26", "35", "", "", "88.0", "80.2", "", "58.6", "", "2", "", "", "201", "1", "1", "38", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.7", "94.4", "", "", "", "", "93.9"]} -{"pcdb_id": 15805, "brand_name": "Firebird", "model_name": "Enviromax Kitchen C35", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 35.0, "final_year_of_manufacture": 2010, "raw": ["015805", "000047", "0", "2012/Mar/27 10:12", "Firebird Boilers", "Firebird", "Enviromax Kitchen C35", "", "", "2007", "2010", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "26", "35", "", "", "88.0", "80.2", "", "58.6", "", "2", "", "", "201", "1", "1", "38", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.7", "94.4", "", "", "", "", "93.9"]} -{"pcdb_id": 15806, "brand_name": "Firebird", "model_name": "Enviromax Utility C35", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 35.0, "final_year_of_manufacture": 2010, "raw": ["015806", "000047", "0", "2012/Mar/27 10:12", "Firebird Boilers", "Firebird", "Enviromax Utility C35", "", "", "2007", "2010", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "26", "35", "", "", "88.0", "80.2", "", "58.6", "", "2", "", "", "201", "1", "1", "38", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.7", "94.4", "", "", "", "", "93.9"]} -{"pcdb_id": 15807, "brand_name": "Firebird", "model_name": "Enviromax System C44", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 80.7, "comparative_hot_water_efficiency_pct": 58.9, "output_kw_max": 44.0, "final_year_of_manufacture": null, "raw": ["015807", "000047", "0", "2012/Mar/27 10:12", "Firebird Boilers", "Firebird", "Enviromax System C44", "", "", "2007", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "35", "44", "", "", "88.5", "80.7", "", "58.9", "", "2", "", "", "201", "1", "1", "38", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.4", "95.8", "", "", "", "", "94.9"]} -{"pcdb_id": 15808, "brand_name": "Firebird", "model_name": "Enviromax Systempac C44", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 80.7, "comparative_hot_water_efficiency_pct": 58.9, "output_kw_max": 44.0, "final_year_of_manufacture": null, "raw": ["015808", "000047", "0", "2012/Mar/27 10:12", "Firebird Boilers", "Firebird", "Enviromax Systempac C44", "", "", "2007", "current", "4", "1", "2", "1", "0", "", "", "2", "1", "1", "35", "44", "", "", "88.5", "80.7", "", "58.9", "", "2", "", "", "201", "1", "1", "38", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.4", "95.8", "", "", "", "", "94.9"]} -{"pcdb_id": 15809, "brand_name": "Firebird", "model_name": "Enviromax Popular C44", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 80.7, "comparative_hot_water_efficiency_pct": 58.9, "output_kw_max": 44.0, "final_year_of_manufacture": null, "raw": ["015809", "000047", "0", "2012/Mar/27 10:12", "Firebird Boilers", "Firebird", "Enviromax Popular C44", "", "", "2007", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "35", "44", "", "", "88.5", "80.7", "", "58.9", "", "2", "", "", "201", "1", "1", "38", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.4", "95.8", "", "", "", "", "94.9"]} -{"pcdb_id": 15810, "brand_name": "Firebird", "model_name": "Enviromax Heatpac C44", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 80.7, "comparative_hot_water_efficiency_pct": 58.9, "output_kw_max": 44.0, "final_year_of_manufacture": null, "raw": ["015810", "000047", "0", "2012/Mar/27 10:12", "Firebird Boilers", "Firebird", "Enviromax Heatpac C44", "", "", "2007", "current", "4", "1", "2", "1", "0", "", "", "2", "1", "1", "35", "44", "", "", "88.5", "80.7", "", "58.9", "", "2", "", "", "201", "1", "1", "338", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.4", "95.8", "", "", "", "", "94.9"]} -{"pcdb_id": 15811, "brand_name": "Firebird", "model_name": "Enviromax Kitchen C44", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 80.7, "comparative_hot_water_efficiency_pct": 58.9, "output_kw_max": 44.0, "final_year_of_manufacture": null, "raw": ["015811", "000047", "0", "2012/Mar/27 10:12", "Firebird Boilers", "Firebird", "Enviromax Kitchen C44", "", "", "2007", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "35", "44", "", "", "88.5", "80.7", "", "58.9", "", "2", "", "", "201", "1", "1", "38", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.4", "95.8", "", "", "", "", "94.9"]} -{"pcdb_id": 15812, "brand_name": "Firebird", "model_name": "Enviromax Popular C58", "model_qualifier": "", "winter_efficiency_pct": 87.8, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 58.0, "final_year_of_manufacture": null, "raw": ["015812", "000047", "0", "2012/Mar/27 10:12", "Firebird Boilers", "Firebird", "Enviromax Popular C58", "", "", "2007", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "44", "58", "", "", "87.8", "80.0", "", "58.5", "", "2", "", "", "201", "1", "1", "38", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.2", "94.3", "", "", "", "", "93.7"]} -{"pcdb_id": 15813, "brand_name": "Firebird", "model_name": "Enviromax Heatpac C58", "model_qualifier": "", "winter_efficiency_pct": 87.8, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 58.0, "final_year_of_manufacture": null, "raw": ["015813", "000047", "0", "2012/Mar/27 10:12", "Firebird Boilers", "Firebird", "Enviromax Heatpac C58", "", "", "2007", "current", "4", "1", "2", "1", "0", "", "", "2", "1", "1", "44", "58", "", "", "87.8", "80.0", "", "58.5", "", "2", "", "", "201", "1", "1", "38", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.2", "94.3", "", "", "", "", "93.7"]} -{"pcdb_id": 15814, "brand_name": "Firebird", "model_name": "Enviromax Kitchen C58", "model_qualifier": "", "winter_efficiency_pct": 87.8, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 58.0, "final_year_of_manufacture": null, "raw": ["015814", "000047", "0", "2012/Mar/27 10:12", "Firebird Boilers", "Firebird", "Enviromax Kitchen C58", "", "", "2007", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "44", "58", "", "", "87.8", "80.0", "", "58.5", "", "2", "", "", "201", "1", "1", "38", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.2", "94.3", "", "", "", "", "93.7"]} -{"pcdb_id": 15815, "brand_name": "Firebird", "model_name": "Enviromax Popular C73", "model_qualifier": "", "winter_efficiency_pct": 87.5, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": null, "final_year_of_manufacture": null, "raw": ["015815", "000047", "0", "2012/Mar/27 10:12", "Firebird Boilers", "Firebird", "Enviromax Popular C73", "", "", "2007", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "58", ">70kW", "", "", "87.5", "79.7", "", "58.2", "", "2", "", "", "201", "1", "1", "38", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.0", "94.0", "", "", "", "", "93.2"]} -{"pcdb_id": 15816, "brand_name": "Firebird", "model_name": "Enviromax Heatpac C73", "model_qualifier": "", "winter_efficiency_pct": 87.5, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": null, "final_year_of_manufacture": null, "raw": ["015816", "000047", "0", "2012/Mar/27 10:12", "Firebird Boilers", "Firebird", "Enviromax Heatpac C73", "", "", "2007", "current", "4", "1", "2", "1", "0", "", "", "2", "1", "1", "58", ">70kW", "", "", "87.5", "79.7", "", "58.2", "", "2", "", "", "201", "1", "1", "38", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.0", "94.0", "", "", "", "", "93.2"]} -{"pcdb_id": 15817, "brand_name": "Firebird", "model_name": "Enviromax Kitchen C73", "model_qualifier": "", "winter_efficiency_pct": 87.5, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": null, "final_year_of_manufacture": null, "raw": ["015817", "000047", "0", "2012/Mar/27 10:12", "Firebird Boilers", "Firebird", "Enviromax Kitchen C73", "", "", "2007", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "58", ">70kW", "", "", "87.5", "79.7", "", "58.2", "", "2", "", "", "201", "1", "1", "38", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.0", "94.0", "", "", "", "", "93.2"]} -{"pcdb_id": 15818, "brand_name": "Sime", "model_name": "Ecomfort", "model_qualifier": "System Plus 25 HE", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 25.0, "final_year_of_manufacture": 2018, "raw": ["015818", "000213", "0", "2018/Feb/26 16:48", "Fonderie Sime S.p.A.", "Sime", "Ecomfort", "System Plus 25 HE", "", "2008", "2018", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "25.0", "25.0", "", "", "88.9", "79.9", "", "58.4", "", "2", "1", "", "102", "1", "2", "150", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "91.0", "98.4", "", "", "", "", "97.0"]} -{"pcdb_id": 15819, "brand_name": "Sime", "model_name": "Ecomfort", "model_qualifier": "System Plus 25 HE", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 78.9, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 25.0, "final_year_of_manufacture": 2018, "raw": ["015819", "000213", "0", "2018/Feb/26 16:47", "Fonderie Sime S.p.A.", "Sime", "Ecomfort", "System Plus 25 HE", "", "2008", "2018", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "25.0", "25.0", "", "", "87.9", "78.9", "", "57.7", "", "2", "", "", "102", "1", "2", "150", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.0", "96.2", "", "", "", "", "94.9"]} -{"pcdb_id": 15820, "brand_name": "Sime", "model_name": "Ecomfort", "model_qualifier": "Plus 25 HE", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 56.5, "output_kw_max": 25.0, "final_year_of_manufacture": 2018, "raw": ["015820", "000213", "0", "2018/Feb/26 16:44", "Fonderie Sime S.p.A.", "Sime", "Ecomfort", "Plus 25 HE", "", "2008", "2018", "2", "2", "1", "2", "0", "", "", "2", "3", "2", "25", "25", "", "", "88.9", "80.3", "", "56.5", "", "2", "1", "", "104", "1", "2", "150", "10", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "91.0", "98.4", "", "", "", "", "97.0"]} -{"pcdb_id": 15821, "brand_name": "Sime", "model_name": "Ecomfort", "model_qualifier": "Plus 25 HE", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 55.8, "output_kw_max": 25.0, "final_year_of_manufacture": 2018, "raw": ["015821", "000213", "0", "2018/Feb/26 16:43", "Fonderie Sime S.p.A.", "Sime", "Ecomfort", "Plus 25 HE", "", "2008", "2018", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "25.0", "25.0", "", "", "87.9", "79.3", "", "55.8", "", "2", "", "", "104", "1", "2", "150", "10", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.0", "96.2", "", "", "", "", "94.9"]} -{"pcdb_id": 15822, "brand_name": "Sime", "model_name": "Ecomfort", "model_qualifier": "Plus 30 HE", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.4, "comparative_hot_water_efficiency_pct": 56.5, "output_kw_max": 29.0, "final_year_of_manufacture": 2018, "raw": ["015822", "000213", "0", "2018/Feb/26 16:45", "Fonderie Sime S.p.A.", "Sime", "Ecomfort", "Plus 30 HE", "", "2008", "2018", "2", "2", "1", "2", "0", "", "", "2", "3", "2", "29.0", "29.0", "", "", "89.0", "80.4", "", "56.5", "", "2", "1", "", "104", "1", "2", "160", "10", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.8", "98.5", "", "", "", "", "97.1"]} -{"pcdb_id": 15823, "brand_name": "Sime", "model_name": "Ecomfort", "model_qualifier": "Plus 30 HE", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 55.8, "output_kw_max": 29.0, "final_year_of_manufacture": 2018, "raw": ["015823", "000213", "0", "2018/Feb/26 16:44", "Fonderie Sime S.p.A.", "Sime", "Ecomfort", "Plus 30 HE", "", "2008", "2018", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "29.0", "29.0", "", "", "88.0", "79.4", "", "55.8", "", "2", "", "", "104", "1", "2", "160", "10", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.8", "96.4", "", "", "", "", "95.0"]} -{"pcdb_id": 15824, "brand_name": "Buderus", "model_name": "Logamax Plus", "model_qualifier": "GB162-65kW", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 65.0, "final_year_of_manufacture": null, "raw": ["015824", "000035", "0", "2012/Mar/27 10:12", "Bosch Thermotechnology", "Buderus", "Logamax Plus", "GB162-65kW", "", "2008", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "65", "65", "", "", "88.2", "79.2", "", "57.8", "", "2", "", "", "102", "1", "2", "99", "21", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "97.1", "", "", "", "", "95.5"]} -{"pcdb_id": 15826, "brand_name": "Radiant", "model_name": "RKR 18", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 56.1, "output_kw_max": 17.7, "final_year_of_manufacture": null, "raw": ["015826", "000088", "0", "2008/Apr/18 11:36", "Radiant Bruciatori SpA", "Radiant", "RKR 18", "", "", "2008", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "17.7", "17.7", "", "", "88.3", "79.7", "", "56.1", "", "2", "", "", "104", "1", "2", "133", "5.4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.6", "97.4", "", "", "", "", "95.7"]} -{"pcdb_id": 15827, "brand_name": "Radiant", "model_name": "RKA 25/8", "model_qualifier": "", "winter_efficiency_pct": 87.7, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 55.6, "output_kw_max": 24.6, "final_year_of_manufacture": null, "raw": ["015827", "000088", "0", "2008/Apr/18 11:36", "Radiant Bruciatori SpA", "Radiant", "RKA 25/8", "", "", "2008", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.60", "24.60", "", "", "87.7", "79.1", "", "55.6", "", "2", "", "", "104", "1", "2", "170", "5.4", "0", "", "", "13", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.7", "95.8", "", "", "", "", "94.4"]} -{"pcdb_id": 15828, "brand_name": "Radiant", "model_name": "RKA 18/100", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 81.6, "comparative_hot_water_efficiency_pct": 36.8, "output_kw_max": 17.7, "final_year_of_manufacture": null, "raw": ["015828", "000088", "0", "2024/Jan/31 10:17", "Radiant Bruciatori SpA", "Radiant", "RKA 18/100", "", "", "2008", "current", "1", "1", "1", "2", "0", "", "", "2", "2", "2", "17.7", "17.7", "", "", "88.3", "81.6", "", "36.8", "", "2", "", "", "106", "1", "2", "150", "5.4", "2", "2", "0", "105", "0", "15", "2", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.6", "97.4", "", "", "", "", "95.7"]} -{"pcdb_id": 15829, "brand_name": "Radiant", "model_name": "RKA 18/8", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 56.1, "output_kw_max": 17.7, "final_year_of_manufacture": null, "raw": ["015829", "000088", "0", "2008/Apr/18 11:36", "Radiant Bruciatori SpA", "Radiant", "RKA 18/8", "", "", "2008", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "17.7", "17.7", "", "", "88.3", "79.7", "", "56.1", "", "2", "", "", "104", "1", "2", "133", "5.4", "0", "", "", "13", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.6", "97.4", "", "", "", "", "95.7"]} -{"pcdb_id": 15830, "brand_name": "Radiant", "model_name": "RKA 18", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 81.1, "comparative_hot_water_efficiency_pct": 46.7, "output_kw_max": 17.7, "final_year_of_manufacture": null, "raw": ["015830", "000088", "0", "2024/Jan/31 10:17", "Radiant Bruciatori SpA", "Radiant", "RKA 18", "", "", "2008", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "17.7", "17.7", "", "", "88.3", "81.1", "", "46.7", "", "2", "", "", "106", "1", "2", "133", "5.4", "2", "2", "0", "20", "0", "15", "2", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.6", "97.4", "", "", "", "", "95.7"]} -{"pcdb_id": 15831, "brand_name": "Radiant", "model_name": "RK 18/B", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 17.7, "final_year_of_manufacture": null, "raw": ["015831", "000088", "0", "2012/Mar/27 10:12", "Radiant Bruciatori SpA", "Radiant", "RK 18/B", "", "", "2008", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "17.7", "17.7", "", "", "88.3", "79.3", "", "57.9", "", "2", "", "", "102", "1", "2", "130", "5.4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.6", "97.4", "", "", "", "", "95.7"]} -{"pcdb_id": 15832, "brand_name": "Radiant", "model_name": "RK 18", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 17.7, "final_year_of_manufacture": null, "raw": ["015832", "000088", "0", "2012/Mar/27 10:12", "Radiant Bruciatori SpA", "Radiant", "RK 18", "", "", "2008", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "17.7", "17.7", "", "", "88.3", "79.3", "", "57.9", "", "2", "", "", "102", "1", "2", "130", "5.4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.6", "97.4", "", "", "", "", "95.7"]} -{"pcdb_id": 15833, "brand_name": "Glow-worm", "model_name": "Betacom 30c", "model_qualifier": "", "winter_efficiency_pct": 85.1, "summer_efficiency_pct": 76.5, "comparative_hot_water_efficiency_pct": 53.8, "output_kw_max": 27.6, "final_year_of_manufacture": 2013, "raw": ["015833", "000207", "0", "2013/Aug/23 09:30", "Vaillant Group UK", "Glow-worm", "Betacom 30c", "", "47-019-09", "2008", "2013", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "27.6", "27.6", "", "", "85.1", "76.5", "", "53.8", "", "2", "", "", "104", "1", "2", "164", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.2", "89.7", "", "", "", "", "89.3"]} -{"pcdb_id": 15834, "brand_name": "Glow-worm", "model_name": "Betacom 24c", "model_qualifier": "", "winter_efficiency_pct": 85.0, "summer_efficiency_pct": 76.4, "comparative_hot_water_efficiency_pct": 53.7, "output_kw_max": 24.7, "final_year_of_manufacture": 2013, "raw": ["015834", "000207", "0", "2013/Aug/23 09:29", "Vaillant Group UK", "Glow-worm", "Betacom 24c", "", "47-019-08", "2008", "2013", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.7", "24.7", "", "", "85.0", "76.4", "", "53.7", "", "2", "", "", "104", "1", "2", "164", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "86.5", "89.7", "", "", "", "", "89.1"]} -{"pcdb_id": 15835, "brand_name": "Johnson & Starley", "model_name": "RenoXtra", "model_qualifier": "30 CP", "winter_efficiency_pct": 89.8, "summer_efficiency_pct": 81.2, "comparative_hot_water_efficiency_pct": 57.1, "output_kw_max": 25.0, "final_year_of_manufacture": null, "raw": ["015835", "000239", "0", "2008/Sep/29 16:19", "Johnson & Starley", "Johnson & Starley", "RenoXtra", "30 CP", "", "2008", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "25", "25", "", "", "89.8", "81.2", "", "57.1", "", "2", "1", "", "104", "1", "2", "145", "0", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.6", "101.0", "", "", "", "", "98.9"]} -{"pcdb_id": 15836, "brand_name": "Johnson & Starley", "model_name": "RenoXtra", "model_qualifier": "37 CP", "winter_efficiency_pct": 90.1, "summer_efficiency_pct": 81.5, "comparative_hot_water_efficiency_pct": 57.3, "output_kw_max": 30.0, "final_year_of_manufacture": null, "raw": ["015836", "000239", "0", "2008/Sep/29 16:19", "Johnson & Starley", "Johnson & Starley", "RenoXtra", "37 CP", "", "2008", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "30", "30", "", "", "90.1", "81.5", "", "57.3", "", "2", "1", "", "104", "1", "2", "145", "0", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.8", "101.7", "", "", "", "", "99.4"]} -{"pcdb_id": 15837, "brand_name": "Johnson & Starley", "model_name": "RenoXtra", "model_qualifier": "37C", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.4, "comparative_hot_water_efficiency_pct": 56.6, "output_kw_max": 30.0, "final_year_of_manufacture": null, "raw": ["015837", "000239", "0", "2010/Sep/29 12:36", "Johnson & Starley", "Johnson & Starley", "RenoXtra", "37C", "", "2008", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "30", "30", "", "", "89.0", "80.4", "", "56.6", "", "2", "", "", "104", "1", "2", "145", "0", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "99.5", "", "", "", "", "97.3"]} -{"pcdb_id": 15838, "brand_name": "Johnson & Starley", "model_name": "RenoXtra", "model_qualifier": "30C", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 56.4, "output_kw_max": 25.0, "final_year_of_manufacture": null, "raw": ["015838", "000239", "0", "2010/Sep/29 12:36", "Johnson & Starley", "Johnson & Starley", "RenoXtra", "30C", "", "2008", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "25", "25", "", "", "88.8", "80.2", "", "56.4", "", "2", "", "", "104", "1", "2", "145", "0", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.7", "98.8", "", "", "", "", "96.7"]} -{"pcdb_id": 15840, "brand_name": "Grant", "model_name": "Euroflame Condensing", "model_qualifier": "Module 90-120", "winter_efficiency_pct": 87.5, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 34.7, "final_year_of_manufacture": null, "raw": ["015840", "000048", "0", "2012/Mar/27 10:12", "Grant Engineering", "Grant", "Euroflame Condensing", "Module 90-120", "", "2008", "current", "4", "1", "2", "1", "0", "", "", "2", "3", "2", "25.6", "34.7", "", "", "87.5", "79.7", "", "58.2", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.3", "93.8", "", "", "", "", "93.1"]} -{"pcdb_id": 15841, "brand_name": "Heatline", "model_name": "Capriz", "model_qualifier": "25", "winter_efficiency_pct": 85.0, "summer_efficiency_pct": 76.4, "comparative_hot_water_efficiency_pct": 53.7, "output_kw_max": 24.7, "final_year_of_manufacture": 2009, "raw": ["015841", "000215", "0", "2011/Aug/31 10:42", "Turk Demir Dokum Fab AS", "Heatline", "Capriz", "25", "GC No 47-157-12", "2008", "2009", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.7", "24.7", "", "", "85.0", "76.4", "", "53.7", "", "2", "", "", "104", "1", "2", "175", "10", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "86.5", "89.7", "", "", "", "", "89.1"]} -{"pcdb_id": 15842, "brand_name": "Heatline", "model_name": "Capriz", "model_qualifier": "28", "winter_efficiency_pct": 85.1, "summer_efficiency_pct": 76.5, "comparative_hot_water_efficiency_pct": 53.8, "output_kw_max": 27.6, "final_year_of_manufacture": 2009, "raw": ["015842", "000215", "0", "2011/Aug/31 10:42", "Turk Demir Dokum Fab AS", "Heatline", "Capriz", "28", "GC No 47-157-13", "2008", "2009", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "27.6", "27.6", "", "", "85.1", "76.5", "", "53.8", "", "2", "", "", "104", "1", "2", "175", "10", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.2", "89.7", "", "", "", "", "89.3"]} -{"pcdb_id": 15843, "brand_name": "Heatline", "model_name": "Capriz", "model_qualifier": "25S", "winter_efficiency_pct": 85.0, "summer_efficiency_pct": 76.0, "comparative_hot_water_efficiency_pct": 55.5, "output_kw_max": 24.7, "final_year_of_manufacture": 2009, "raw": ["015843", "000215", "0", "2012/Mar/27 10:12", "Turk Demir Dokum Fab AS", "Heatline", "Capriz", "25S", "GC No 41-157-10", "2008", "2009", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24.7", "24.7", "", "", "85.0", "76.0", "", "55.5", "", "2", "", "", "102", "1", "2", "175", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "86.5", "89.7", "", "", "", "", "89.1"]} -{"pcdb_id": 15844, "brand_name": "Heatline", "model_name": "Capriz", "model_qualifier": "28S", "winter_efficiency_pct": 85.1, "summer_efficiency_pct": 76.1, "comparative_hot_water_efficiency_pct": 55.6, "output_kw_max": 27.6, "final_year_of_manufacture": 2009, "raw": ["015844", "000215", "0", "2012/Mar/27 10:12", "Turk Demir Dokum Fab AS", "Heatline", "Capriz", "28S", "GC No 41-157-11", "2008", "2009", "1", "2", "1", "1", "0", "", "", "2", "1", "2", "27.6", "27.6", "", "", "85.1", "76.1", "", "55.6", "", "2", "", "", "102", "1", "2", "175", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.2", "89.7", "", "", "", "", "89.3"]} -{"pcdb_id": 15845, "brand_name": "Hyrdoline", "model_name": "B24", "model_qualifier": "", "winter_efficiency_pct": 85.0, "summer_efficiency_pct": 76.4, "comparative_hot_water_efficiency_pct": 53.7, "output_kw_max": 24.7, "final_year_of_manufacture": 2008, "raw": ["015845", "000215", "0", "2011/Aug/31 10:42", "Turk Demir Dokum Fab AS", "Hyrdoline", "B24", "", "GC No 47-157-18", "2008", "2008", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.7", "24.7", "", "", "85.0", "76.4", "", "53.7", "", "2", "", "", "104", "1", "2", "175", "10", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "86.5", "89.7", "", "", "", "", "89.1"]} -{"pcdb_id": 15846, "brand_name": "Heatline", "model_name": "Sargon", "model_qualifier": "24", "winter_efficiency_pct": 87.8, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 55.7, "output_kw_max": 19.5, "final_year_of_manufacture": 2009, "raw": ["015846", "000215", "0", "2011/Aug/31 10:38", "Turk Demir Dokum Fab AS", "Heatline", "Sargon", "24", "GC No 47-157-15", "2008", "2009", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "19.5", "19.5", "", "", "87.8", "79.2", "", "55.7", "", "2", "", "", "104", "1", "2", "175", "10", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "96.4", "", "", "", "", "94.8"]} -{"pcdb_id": 15849, "brand_name": "Heatline", "model_name": "Sargon", "model_qualifier": "30", "winter_efficiency_pct": 87.8, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 55.7, "output_kw_max": 24.4, "final_year_of_manufacture": 2009, "raw": ["015849", "000215", "0", "2011/Aug/31 10:38", "Turk Demir Dokum Fab AS", "Heatline", "Sargon", "30", "GC No 47-157-16", "2008", "2009", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.4", "24.4", "", "", "87.8", "79.2", "", "55.7", "", "2", "", "", "104", "1", "2", "175", "10", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "96.4", "", "", "", "", "94.8"]} -{"pcdb_id": 15850, "brand_name": "Heatline", "model_name": "Sargon", "model_qualifier": "35", "winter_efficiency_pct": 87.8, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 55.7, "output_kw_max": 29.8, "final_year_of_manufacture": 2009, "raw": ["015850", "000215", "0", "2011/Aug/31 10:40", "Turk Demir Dokum Fab AS", "Heatline", "Sargon", "35", "GC no 47-157-17", "2008", "2009", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "29.8", "29.8", "", "", "87.8", "79.2", "", "55.7", "", "2", "", "", "104", "1", "2", "175", "10", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "96.3", "", "", "", "", "94.7"]} -{"pcdb_id": 15851, "brand_name": "Heatline", "model_name": "Sargon", "model_qualifier": "20S", "winter_efficiency_pct": 87.8, "summer_efficiency_pct": 78.8, "comparative_hot_water_efficiency_pct": 57.6, "output_kw_max": 19.5, "final_year_of_manufacture": 2009, "raw": ["015851", "000215", "0", "2012/Mar/27 10:12", "Turk Demir Dokum Fab AS", "Heatline", "Sargon", "20S", "GC No 41-157-12", "2008", "2009", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "19.5", "19.5", "", "", "87.8", "78.8", "", "57.6", "", "2", "", "", "102", "1", "2", "175", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "96.4", "", "", "", "", "94.8"]} -{"pcdb_id": 15852, "brand_name": "Heatline", "model_name": "Sargon", "model_qualifier": "24S", "winter_efficiency_pct": 87.8, "summer_efficiency_pct": 78.8, "comparative_hot_water_efficiency_pct": 57.6, "output_kw_max": 24.4, "final_year_of_manufacture": 2009, "raw": ["015852", "000215", "0", "2012/Mar/27 10:12", "Turk Demir Dokum Fab AS", "Heatline", "Sargon", "24S", "GC No 41-157-13", "2008", "2009", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24.4", "24.4", "", "", "87.8", "78.8", "", "57.6", "", "2", "", "", "102", "1", "2", "175", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "96.4", "", "", "", "", "94.8"]} -{"pcdb_id": 15853, "brand_name": "Heatline", "model_name": "Sargon", "model_qualifier": "30S", "winter_efficiency_pct": 87.8, "summer_efficiency_pct": 78.8, "comparative_hot_water_efficiency_pct": 57.6, "output_kw_max": 29.8, "final_year_of_manufacture": 2009, "raw": ["015853", "000215", "0", "2012/Mar/27 10:12", "Turk Demir Dokum Fab AS", "Heatline", "Sargon", "30S", "GC No 41-157-13", "2008", "2009", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "29.8", "29.8", "", "", "87.8", "78.8", "", "57.6", "", "2", "", "", "102", "1", "2", "175", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "96.3", "", "", "", "", "94.7"]} -{"pcdb_id": 15854, "brand_name": "Grant", "model_name": "Euroflame Condensing", "model_qualifier": "Indoor 50-70", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 20.7, "final_year_of_manufacture": null, "raw": ["015854", "000048", "0", "2012/Mar/27 10:12", "Grant Engineering", "Grant", "Euroflame Condensing", "Indoor 50-70", "", "2008", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "15", "20.7", "", "", "88.0", "80.2", "", "58.6", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.5", "94.4", "", "", "", "", "93.9"]} -{"pcdb_id": 15855, "brand_name": "Grant", "model_name": "Euroflame Condensing", "model_qualifier": "Indoor 70-90", "winter_efficiency_pct": 87.8, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 25.6, "final_year_of_manufacture": null, "raw": ["015855", "000048", "0", "2012/Mar/27 10:12", "Grant Engineering", "Grant", "Euroflame Condensing", "Indoor 70-90", "", "2008", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "20.7", "25.6", "", "", "87.8", "80.0", "", "58.4", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.4", "94.4", "", "", "", "", "93.6"]} -{"pcdb_id": 15856, "brand_name": "Grant", "model_name": "Euroflame Condensing", "model_qualifier": "Indoor 90-120", "winter_efficiency_pct": 87.5, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 34.7, "final_year_of_manufacture": null, "raw": ["015856", "000048", "0", "2012/Mar/27 10:12", "Grant Engineering", "Grant", "Euroflame Condensing", "Indoor 90-120", "", "2008", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "25.6", "34.7", "", "", "87.5", "79.7", "", "58.2", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.3", "93.8", "", "", "", "", "93.1"]} -{"pcdb_id": 15857, "brand_name": "Grant", "model_name": "Euroflame Condensing", "model_qualifier": "Boilerhouse 50-70", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 20.7, "final_year_of_manufacture": null, "raw": ["015857", "000048", "0", "2012/Mar/27 10:12", "Grant Engineering", "Grant", "Euroflame Condensing", "Boilerhouse 50-70", "", "2008", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "15", "20.7", "", "", "88.0", "80.2", "", "58.6", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.5", "94.4", "", "", "", "", "93.9"]} -{"pcdb_id": 15858, "brand_name": "Grant", "model_name": "Euroflame Condensing", "model_qualifier": "Boilerhouse 70-90", "winter_efficiency_pct": 87.8, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 25.6, "final_year_of_manufacture": null, "raw": ["015858", "000048", "0", "2012/Mar/27 10:12", "Grant Engineering", "Grant", "Euroflame Condensing", "Boilerhouse 70-90", "", "2008", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "20.7", "25.6", "", "", "87.8", "80.0", "", "58.4", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.4", "94.4", "", "", "", "", "93.6"]} -{"pcdb_id": 15859, "brand_name": "Grant", "model_name": "Euroflame Condensing", "model_qualifier": "Boilerhouse 90-120", "winter_efficiency_pct": 87.5, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 34.7, "final_year_of_manufacture": null, "raw": ["015859", "000048", "0", "2012/Mar/27 10:12", "Grant Engineering", "Grant", "Euroflame Condensing", "Boilerhouse 90-120", "", "2008", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "25.6", "34.7", "", "", "87.5", "79.7", "", "58.2", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.3", "93.8", "", "", "", "", "93.1"]} -{"pcdb_id": 15860, "brand_name": "Grant", "model_name": "Euroflame Condensing", "model_qualifier": "Module 50-70", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 20.7, "final_year_of_manufacture": null, "raw": ["015860", "000048", "0", "2012/Mar/27 10:12", "Grant Engineering", "Grant", "Euroflame Condensing", "Module 50-70", "", "2008", "current", "4", "1", "2", "1", "0", "", "", "2", "3", "2", "15", "20.7", "", "", "88.0", "80.2", "", "58.6", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.5", "94.4", "", "", "", "", "93.9"]} -{"pcdb_id": 15861, "brand_name": "Grant", "model_name": "Euroflame Condensing", "model_qualifier": "Module 70-90", "winter_efficiency_pct": 87.8, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 25.6, "final_year_of_manufacture": null, "raw": ["015861", "000048", "0", "2012/Mar/27 10:12", "Grant Engineering", "Grant", "Euroflame Condensing", "Module 70-90", "", "2008", "current", "4", "1", "2", "1", "0", "", "", "2", "3", "2", "20.7", "25.6", "", "", "87.8", "80.0", "", "58.4", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.4", "94.4", "", "", "", "", "93.6"]} -{"pcdb_id": 15862, "brand_name": "Viessmann", "model_name": "Vitodens 100-w wb1a", "model_qualifier": "13kW", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 11.8, "final_year_of_manufacture": 2007, "raw": ["015862", "000033", "0", "2012/Mar/27 10:12", "Viessmann", "Viessmann", "Vitodens 100-w wb1a", "13kW", "", "2007", "2007", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "11.8", "11.8", "", "", "88.7", "79.7", "", "58.2", "", "2", "", "", "102", "1", "2", "55", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.3", "98.1", "", "", "", "", "96.4"]} -{"pcdb_id": 15863, "brand_name": "Viessmann", "model_name": "Vitodens 200-W WB2B", "model_qualifier": "19kW System boiler", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 17.5, "final_year_of_manufacture": 2012, "raw": ["015863", "000033", "0", "2012/Mar/27 10:12", "Viessmann", "Viessmann", "Vitodens 200-W WB2B", "19kW System boiler", "", "2007", "2012", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "17.5", "17.5", "", "", "88.3", "79.3", "", "58.0", "", "2", "", "", "102", "1", "2", "85", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "97.7", "", "", "", "", "95.8"]} -{"pcdb_id": 15864, "brand_name": "Viessmann", "model_name": "Vitodens 200-W WB2B", "model_qualifier": "19kW System boiler", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 80.4, "comparative_hot_water_efficiency_pct": 58.7, "output_kw_max": 17.5, "final_year_of_manufacture": 2012, "raw": ["015864", "000033", "0", "2012/Mar/27 10:12", "Viessmann", "Viessmann", "Vitodens 200-W WB2B", "19kW System boiler", "", "2007", "2012", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "17.5", "17.5", "", "", "89.4", "80.4", "", "58.7", "", "2", "1", "", "102", "1", "2", "85", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.0", "99.8", "", "", "", "", "98.0"]} -{"pcdb_id": 15865, "brand_name": "Viessmann", "model_name": "Vitodens 200-W WB2B", "model_qualifier": "26 kW System boiler", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 24.1, "final_year_of_manufacture": 2012, "raw": ["015865", "000033", "0", "2012/Aug/28 09:47", "Viessmann", "Viessmann", "Vitodens 200-W WB2B", "26 kW System boiler", "", "2007", "2012", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24.1", "24.1", "", "", "88.6", "79.6", "", "58.1", "", "2", "", "", "102", "1", "2", "95", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.9", "97.9", "", "", "", "", "96.2"]} -{"pcdb_id": 15866, "brand_name": "Viessmann", "model_name": "Vitodens 200-W WB2B", "model_qualifier": "26kW System boiler", "winter_efficiency_pct": 89.6, "summer_efficiency_pct": 80.6, "comparative_hot_water_efficiency_pct": 58.9, "output_kw_max": 24.1, "final_year_of_manufacture": 2012, "raw": ["015866", "000033", "0", "2012/Mar/27 10:12", "Viessmann", "Viessmann", "Vitodens 200-W WB2B", "26kW System boiler", "", "2007", "2012", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "24.1", "24.1", "", "", "89.6", "80.6", "", "58.9", "", "2", "1", "", "102", "1", "2", "95", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.9", "100.1", "", "", "", "", "98.4"]} -{"pcdb_id": 15867, "brand_name": "Viessmann", "model_name": "Vitodens 200-W WB2B", "model_qualifier": "30kW Combi boiler", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 56.2, "output_kw_max": 27.8, "final_year_of_manufacture": 2012, "raw": ["015867", "000033", "0", "2012/Jun/28 11:05", "Viessmann", "Viessmann", "Vitodens 200-W WB2B", "30kW Combi boiler", "", "2007", "2012", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "27.8", "27.8", "", "", "88.6", "80.0", "", "56.2", "", "2", "", "", "104", "1", "2", "115", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.2", "97.8", "", "", "", "", "96.1"]} -{"pcdb_id": 15868, "brand_name": "Viessmann", "model_name": "Vitodens 200-W WB2B", "model_qualifier": "30kW Combi boiler", "winter_efficiency_pct": 89.6, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 57.0, "output_kw_max": 27.8, "final_year_of_manufacture": 2012, "raw": ["015868", "000033", "0", "2008/Sep/29 16:10", "Viessmann", "Viessmann", "Vitodens 200-W WB2B", "30kW Combi boiler", "", "2007", "2012", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "27.8", "27.8", "", "", "89.6", "81.0", "", "57.0", "", "2", "1", "", "104", "1", "2", "115", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "91.2", "99.9", "", "", "", "", "98.3"]} -{"pcdb_id": 15869, "brand_name": "Viessmann", "model_name": "Vitodens 200-W WB2B", "model_qualifier": "35kW Combi boiler", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 56.2, "output_kw_max": 32.2, "final_year_of_manufacture": 2012, "raw": ["015869", "000033", "0", "2012/Jun/28 11:05", "Viessmann", "Viessmann", "Vitodens 200-W WB2B", "35kW Combi boiler", "", "2007", "2012", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "32.2", "32.2", "", "", "88.5", "79.9", "", "56.2", "", "2", "", "", "104", "1", "2", "115", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.7", "97.8", "", "", "", "", "96.0"]} -{"pcdb_id": 15870, "brand_name": "Viessmann", "model_name": "Vitodens 200-W WB2B", "model_qualifier": "35kW Combi boiler", "winter_efficiency_pct": 90.4, "summer_efficiency_pct": 81.8, "comparative_hot_water_efficiency_pct": 57.5, "output_kw_max": 32.2, "final_year_of_manufacture": 2012, "raw": ["015870", "000033", "0", "2010/Mar/11 12:40", "Viessmann", "Viessmann", "Vitodens 200-W WB2B", "35kW Combi boiler", "", "2007", "2012", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "32.2", "32.2", "", "", "90.4", "81.8", "", "57.5", "", "2", "0", "", "104", "1", "2", "115", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.7", "99.6", "", "", "", "", "97.9"]} -{"pcdb_id": 15871, "brand_name": "Viessmann", "model_name": "Vitodens 343F", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 81.1, "comparative_hot_water_efficiency_pct": 41.7, "output_kw_max": 11.8, "final_year_of_manufacture": 2012, "raw": ["015871", "000033", "0", "2024/Jan/31 10:17", "Viessmann", "Viessmann", "Vitodens 343F", "", "", "2008", "2012", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "11.8", "11.8", "", "", "88.4", "81.1", "", "41.7", "", "2", "", "", "106", "1", "2", "126", "", "2", "1", "0", "250", "0", "50", "5", "60", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "97.8", "", "", "", "", "95.9"]} -{"pcdb_id": 15872, "brand_name": "Viessmann", "model_name": "Vitodens 343F", "model_qualifier": "", "winter_efficiency_pct": 90.4, "summer_efficiency_pct": 83.1, "comparative_hot_water_efficiency_pct": 42.7, "output_kw_max": 11.8, "final_year_of_manufacture": 2012, "raw": ["015872", "000033", "0", "2024/Jan/31 10:17", "Viessmann", "Viessmann", "Vitodens 343F", "", "", "2008", "2012", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "11.8", "11.8", "", "", "90.4", "83.1", "", "42.7", "", "2", "0", "", "106", "1", "2", "126", "", "2", "1", "0", "250", "0", "50", "5", "60", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.7", "100.0", "", "", "", "", "98.1"]} -{"pcdb_id": 15873, "brand_name": "Potterton", "model_name": "Promax Combi", "model_qualifier": "24 HE Plus LPG", "winter_efficiency_pct": 90.4, "summer_efficiency_pct": 81.8, "comparative_hot_water_efficiency_pct": 57.5, "output_kw_max": 20.0, "final_year_of_manufacture": 2012, "raw": ["015873", "000005", "0", "2013/May/07 10:36", "Baxi Heating UK", "Potterton", "Promax Combi", "24 HE Plus LPG", "GC No. 47-393-24", "2008", "2012", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "20.0", "20.0", "", "", "90.4", "81.8", "", "57.5", "", "2", "0", "", "104", "1", "2", "155", "5", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "92.0", "99.0", "", "", "", "", "97.7"]} -{"pcdb_id": 15874, "brand_name": "Potterton", "model_name": "Promax System", "model_qualifier": "24 HE Plus LPG", "winter_efficiency_pct": 90.4, "summer_efficiency_pct": 81.4, "comparative_hot_water_efficiency_pct": 59.4, "output_kw_max": 24.0, "final_year_of_manufacture": 2012, "raw": ["015874", "000005", "0", "2013/May/07 10:36", "Baxi Heating UK", "Potterton", "Promax System", "24 HE Plus LPG", "GC No. 41-592-11", "2008", "2012", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "24.0", "24.0", "", "", "90.4", "81.4", "", "59.4", "", "2", "0", "", "102", "1", "2", "150", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "91.9", "99.0", "", "", "", "", "97.7"]} -{"pcdb_id": 15875, "brand_name": "Baxi", "model_name": "Duo-tec Combi", "model_qualifier": "28 HE LPG", "winter_efficiency_pct": 90.4, "summer_efficiency_pct": 81.8, "comparative_hot_water_efficiency_pct": 57.5, "output_kw_max": 24.0, "final_year_of_manufacture": 2012, "raw": ["015875", "000005", "0", "2013/May/07 10:36", "Baxi Heating UK", "Baxi", "Duo-tec Combi", "28 HE LPG", "GC No. 47-075-39", "2008", "2012", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24.0", "24.0", "", "", "90.4", "81.8", "", "57.5", "", "2", "0", "", "104", "1", "2", "155", "5", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "92.0", "99.0", "", "", "", "", "97.7"]} -{"pcdb_id": 15877, "brand_name": "Rinnai UK", "model_name": "E32S", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 28.2, "final_year_of_manufacture": null, "raw": ["015877", "000253", "0", "2012/Mar/27 10:12", "ATAG Verwarming Nederland BV", "Rinnai UK", "E32S", "", "", "2008", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "28.2", "28.2", "", "", "88.8", "79.8", "", "58.3", "", "2", "", "", "102", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "98.8", "", "", "", "", "96.8"]} -{"pcdb_id": 15879, "brand_name": "Vokera", "model_name": "Mynute", "model_qualifier": "15VHE", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 14.6, "final_year_of_manufacture": null, "raw": ["015879", "000011", "0", "2012/Mar/27 10:12", "Vokera", "Vokera", "Mynute", "15VHE", "41-094-68", "2007", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "14.60", "14.60", "", "", "88.6", "79.6", "", "58.2", "", "2", "", "", "102", "1", "2", "150", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.7", "98.5", "", "", "", "", "96.4"]} -{"pcdb_id": 15881, "brand_name": "Vokera", "model_name": "Mynute", "model_qualifier": "15VHE", "winter_efficiency_pct": 90.1, "summer_efficiency_pct": 81.1, "comparative_hot_water_efficiency_pct": 59.3, "output_kw_max": 14.6, "final_year_of_manufacture": null, "raw": ["015881", "000011", "0", "2012/Mar/27 10:12", "Vokera", "Vokera", "Mynute", "15VHE", "41-094-69", "2007", "current", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "14.60", "14.60", "", "", "90.1", "81.1", "", "59.3", "", "2", "0", "", "102", "1", "2", "150", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.3", "99.5", "", "", "", "", "97.5"]} -{"pcdb_id": 15883, "brand_name": "Ariston", "model_name": "E-Combi 24", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 56.0, "output_kw_max": 21.6, "final_year_of_manufacture": 2013, "raw": ["015883", "000080", "0", "2014/Apr/15 14:58", "Merloni TermoSanitari SpA", "Ariston", "E-Combi 24", "", "47-116-62", "2008", "2013", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "21.6", "21.6", "", "", "88.3", "79.7", "", "56.0", "", "2", "", "", "104", "1", "2", "120", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "97.3", "", "", "", "", "95.6"]} -{"pcdb_id": 15884, "brand_name": "Ariston", "model_name": "E-Combi 30", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 56.1, "output_kw_max": 27.4, "final_year_of_manufacture": 2013, "raw": ["015884", "000080", "0", "2013/Nov/04 15:30", "Merloni TermoSanitari SpA", "Ariston", "E-Combi 30", "", "47-116-63", "2008", "2013", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "27.4", "27.4", "", "", "88.3", "79.7", "", "56.1", "", "2", "", "", "104", "1", "2", "120", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "97.5", "", "", "", "", "95.7"]} -{"pcdb_id": 15885, "brand_name": "Ariston", "model_name": "E-Combi 38", "model_qualifier": "", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 55.8, "output_kw_max": 30.3, "final_year_of_manufacture": 2013, "raw": ["015885", "000080", "0", "2014/Apr/15 14:59", "Merloni TermoSanitari SpA", "Ariston", "E-Combi 38", "", "47-116-64", "2008", "2013", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "30.3", "30.3", "", "", "87.9", "79.3", "", "55.8", "", "2", "", "", "104", "1", "2", "120", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "96.6", "", "", "", "", "94.9"]} -{"pcdb_id": 15886, "brand_name": "Viessmann", "model_name": "Vitodens 200-W WB2B", "model_qualifier": "30 kW System Boiler", "winter_efficiency_pct": 89.6, "summer_efficiency_pct": 80.6, "comparative_hot_water_efficiency_pct": 58.9, "output_kw_max": 27.8, "final_year_of_manufacture": 2012, "raw": ["015886", "000033", "0", "2012/Mar/27 10:12", "Viessmann", "Viessmann", "Vitodens 200-W WB2B", "30 kW System Boiler", "", "2007", "2012", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "27.8", "27.8", "", "", "89.6", "80.6", "", "58.9", "", "2", "1", "", "102", "1", "2", "115", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "91.2", "99.9", "", "", "", "", "98.3"]} -{"pcdb_id": 15887, "brand_name": "Viessmann", "model_name": "Vitodens 200-W WB2B", "model_qualifier": "35kW System Boiler", "winter_efficiency_pct": 89.5, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 58.8, "output_kw_max": 32.2, "final_year_of_manufacture": 2012, "raw": ["015887", "000033", "0", "2012/Mar/27 10:12", "Viessmann", "Viessmann", "Vitodens 200-W WB2B", "35kW System Boiler", "", "2007", "2012", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "32.2", "32.2", "", "", "89.5", "80.5", "", "58.8", "", "2", "1", "", "102", "1", "2", "115", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.6", "99.9", "", "", "", "", "98.2"]} -{"pcdb_id": 15888, "brand_name": "Viessmann", "model_name": "Vitodens 200-W WB2B", "model_qualifier": "26 kW Combi Boiler", "winter_efficiency_pct": 89.6, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 57.0, "output_kw_max": 24.1, "final_year_of_manufacture": 2012, "raw": ["015888", "000033", "0", "2010/Jun/22 10:32", "Viessmann", "Viessmann", "Vitodens 200-W WB2B", "26 kW Combi Boiler", "", "2007", "2012", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24.1", "24.1", "", "", "89.6", "81.0", "", "57.0", "", "2", "1", "", "104", "1", "2", "95", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.9", "100.1", "", "", "", "", "98.4"]} -{"pcdb_id": 15889, "brand_name": "Viessmann", "model_name": "Vitodens 200-W WB2B", "model_qualifier": "30kW System Boiler", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 27.8, "final_year_of_manufacture": 2012, "raw": ["015889", "000033", "0", "2012/Mar/27 10:12", "Viessmann", "Viessmann", "Vitodens 200-W WB2B", "30kW System Boiler", "", "2007", "2012", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "27.8", "27.8", "", "", "88.6", "79.6", "", "58.1", "", "2", "", "", "102", "1", "2", "115", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.2", "97.8", "", "", "", "", "96.1"]} -{"pcdb_id": 15890, "brand_name": "Viessmann", "model_name": "Vitodens 200-W WB2B", "model_qualifier": "35kW System Boiler", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 32.2, "final_year_of_manufacture": 2012, "raw": ["015890", "000033", "0", "2012/Mar/27 10:12", "Viessmann", "Viessmann", "Vitodens 200-W WB2B", "35kW System Boiler", "", "2007", "2012", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "32.2", "32.2", "", "", "88.5", "79.5", "", "58.1", "", "2", "", "", "102", "1", "2", "115", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.7", "97.8", "", "", "", "", "96.0"]} -{"pcdb_id": 15891, "brand_name": "Viessmann", "model_name": "Vitodens 200-W WB2B", "model_qualifier": "26kW Combi Boiler", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 56.3, "output_kw_max": 24.1, "final_year_of_manufacture": 2012, "raw": ["015891", "000033", "0", "2012/Aug/28 09:54", "Viessmann", "Viessmann", "Vitodens 200-W WB2B", "26kW Combi Boiler", "", "2007", "2012", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.1", "24.1", "", "", "88.6", "80.0", "", "56.3", "", "2", "", "", "104", "1", "2", "95", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.9", "97.9", "", "", "", "", "96.2"]} -{"pcdb_id": 15892, "brand_name": "Worcester", "model_name": "Greenstar Danesmoor Wall-Mounted", "model_qualifier": "12/18", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 18.0, "final_year_of_manufacture": 2015, "raw": ["015892", "000035", "0", "2020/Sep/08 10:00", "Bosch Thermotechnology", "Worcester", "Greenstar Danesmoor Wall-Mounted", "12/18", "", "2008", "2015", "4", "2", "1", "1", "0", "", "", "2", "3", "2", "12", "18", "", "", "87.9", "80.1", "", "58.5", "", "2", "", "", "201", "1", "1", "160", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.6", "94.7", "", "", "", "", "93.9"]} -{"pcdb_id": 15893, "brand_name": "Worcester", "model_name": "Greenstar Danesmoor Wall Mounted", "model_qualifier": "18/25", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 25.0, "final_year_of_manufacture": 2015, "raw": ["015893", "000035", "0", "2020/Sep/08 10:00", "Bosch Thermotechnology", "Worcester", "Greenstar Danesmoor Wall Mounted", "18/25", "", "2008", "2015", "4", "2", "1", "1", "0", "", "", "2", "3", "2", "18", "25", "", "", "87.9", "80.1", "", "58.5", "", "2", "", "", "201", "1", "1", "160", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.3", "94.4", "", "", "", "", "93.8"]} -{"pcdb_id": 15894, "brand_name": "Fondital", "model_name": "Tahiti Dual HC 24 Line", "model_qualifier": "", "winter_efficiency_pct": 85.4, "summer_efficiency_pct": 76.8, "comparative_hot_water_efficiency_pct": 54.0, "output_kw_max": 24.4, "final_year_of_manufacture": null, "raw": ["015894", "000250", "0", "2008/Aug/27 11:47", "Fondital", "Fondital", "Tahiti Dual HC 24 Line", "", "", "2008", "current", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "24.4", "24.4", "", "", "85.4", "76.8", "", "54.0", "", "2", "", "", "104", "1", "2", "142", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "86.3", "90.9", "", "", "", "", "90.0"]} -{"pcdb_id": 15895, "brand_name": "Fondital", "model_name": "Tahiti Dual HR 24 Line", "model_qualifier": "", "winter_efficiency_pct": 85.4, "summer_efficiency_pct": 76.4, "comparative_hot_water_efficiency_pct": 55.8, "output_kw_max": 24.4, "final_year_of_manufacture": null, "raw": ["015895", "000250", "0", "2012/Mar/27 10:12", "Fondital", "Fondital", "Tahiti Dual HR 24 Line", "", "", "2008", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "24.4", "24.4", "", "", "85.4", "76.4", "", "55.8", "", "2", "", "", "102", "1", "2", "142", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "86.3", "90.9", "", "", "", "", "90.0"]} -{"pcdb_id": 15897, "brand_name": "Fondital", "model_name": "Tahiti Dual HRB 24 Line", "model_qualifier": "", "winter_efficiency_pct": 85.4, "summer_efficiency_pct": 76.4, "comparative_hot_water_efficiency_pct": 55.8, "output_kw_max": 24.4, "final_year_of_manufacture": null, "raw": ["015897", "000250", "0", "2012/Mar/27 10:12", "Fondital", "Fondital", "Tahiti Dual HRB 24 Line", "", "", "2008", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "24.4", "24.4", "", "", "85.4", "76.4", "", "55.8", "", "2", "", "", "102", "1", "2", "142", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "86.3", "90.9", "", "", "", "", "90.0"]} -{"pcdb_id": 15898, "brand_name": "Alpha", "model_name": "CD 50 S", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 50.0, "final_year_of_manufacture": null, "raw": ["015898", "000001", "0", "2012/Mar/27 10:12", "Alpha Therm", "Alpha", "CD 50 S", "", "", "2008", "current", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "50", "50", "", "", "88.8", "79.8", "", "58.3", "", "2", "1", "", "102", "1", "2", "180", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.7", "98.1", "", "", "", "", "96.7"]} -{"pcdb_id": 15899, "brand_name": "Alpha", "model_name": "CD 50 S", "model_qualifier": "", "winter_efficiency_pct": 87.8, "summer_efficiency_pct": 78.8, "comparative_hot_water_efficiency_pct": 57.6, "output_kw_max": 50.0, "final_year_of_manufacture": null, "raw": ["015899", "000001", "0", "2012/Mar/27 10:12", "Alpha Therm", "Alpha", "CD 50 S", "", "", "2008", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "50", "50", "", "", "87.8", "78.8", "", "57.6", "", "2", "", "", "102", "1", "2", "180", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.7", "96.0", "", "", "", "", "94.6"]} -{"pcdb_id": 15900, "brand_name": "Alpha", "model_name": "CD 70 S", "model_qualifier": "", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 67.9, "final_year_of_manufacture": null, "raw": ["015900", "000001", "0", "2012/Mar/27 10:12", "Alpha Therm", "Alpha", "CD 70 S", "", "", "2008", "current", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "67.9", "67.9", "", "", "89.0", "80.0", "", "58.4", "", "2", "1", "", "102", "1", "2", "270", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.6", "99.1", "", "", "", "", "97.3"]} -{"pcdb_id": 15901, "brand_name": "Alpha", "model_name": "CD 70 S", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 67.9, "final_year_of_manufacture": null, "raw": ["015901", "000001", "0", "2012/Mar/27 10:12", "Alpha Therm", "Alpha", "CD 70 S", "", "", "2008", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "67.9", "67.9", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "270", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.7", "96.9", "", "", "", "", "95.2"]} -{"pcdb_id": 15902, "brand_name": "Fondital", "model_name": "Tahiti Dual HRB 24 Line", "model_qualifier": "", "winter_efficiency_pct": 86.4, "summer_efficiency_pct": 77.4, "comparative_hot_water_efficiency_pct": 56.5, "output_kw_max": 24.4, "final_year_of_manufacture": null, "raw": ["015902", "000250", "0", "2012/Mar/27 10:12", "Fondital", "Fondital", "Tahiti Dual HRB 24 Line", "", "", "2008", "current", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "24.4", "24.4", "", "", "86.4", "77.4", "", "56.5", "", "2", "1", "", "102", "1", "2", "142", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.2", "92.9", "", "", "", "", "92.0"]} -{"pcdb_id": 15903, "brand_name": "Fondital", "model_name": "Tahiti Dual HR 24 Line", "model_qualifier": "", "winter_efficiency_pct": 86.4, "summer_efficiency_pct": 77.4, "comparative_hot_water_efficiency_pct": 56.5, "output_kw_max": 24.4, "final_year_of_manufacture": null, "raw": ["015903", "000250", "0", "2012/Mar/27 10:12", "Fondital", "Fondital", "Tahiti Dual HR 24 Line", "", "", "2008", "current", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "24.4", "24.4", "", "", "86.4", "77.4", "", "56.5", "", "2", "1", "", "102", "1", "2", "142", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.2", "92.9", "", "", "", "", "92.0"]} -{"pcdb_id": 15904, "brand_name": "Fondital", "model_name": "Tahiti Dual HC 24 Line", "model_qualifier": "", "winter_efficiency_pct": 86.4, "summer_efficiency_pct": 77.8, "comparative_hot_water_efficiency_pct": 54.7, "output_kw_max": 24.4, "final_year_of_manufacture": null, "raw": ["015904", "000250", "0", "2008/Aug/27 11:48", "Fondital", "Fondital", "Tahiti Dual HC 24 Line", "", "", "2008", "current", "2", "2", "1", "2", "0", "", "", "2", "3", "2", "24.4", "24.4", "", "", "86.4", "77.8", "", "54.7", "", "2", "1", "", "104", "1", "2", "142", "10", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.2", "92.9", "", "", "", "", "92.0"]} -{"pcdb_id": 15910, "brand_name": "HRM", "model_name": "Wallstar", "model_qualifier": "15/19 Condensing Eco", "winter_efficiency_pct": 83.2, "summer_efficiency_pct": 75.4, "comparative_hot_water_efficiency_pct": 55.1, "output_kw_max": 18.7, "final_year_of_manufacture": null, "raw": ["015910", "000098", "0", "2012/Mar/27 10:12", "HRM Boilers", "HRM", "Wallstar", "15/19 Condensing Eco", "", "2007", "current", "4", "2", "1", "1", "0", "", "", "2", "2", "2", "15", "18.7", "", "", "83.2", "75.4", "", "55.1", "", "2", "", "", "201", "1", "1", "125", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "86.0", "88.2", "", "", "", "", "87.8"]} -{"pcdb_id": 15911, "brand_name": "HRM", "model_name": "Wallstar", "model_qualifier": "15/19 Condensing EOGB", "winter_efficiency_pct": 82.4, "summer_efficiency_pct": 74.6, "comparative_hot_water_efficiency_pct": 54.5, "output_kw_max": 18.8, "final_year_of_manufacture": null, "raw": ["015911", "000098", "0", "2012/Mar/27 10:12", "HRM Boilers", "HRM", "Wallstar", "15/19 Condensing EOGB", "", "2007", "current", "4", "2", "1", "1", "0", "", "", "2", "2", "2", "15", "18.8", "", "", "82.4", "74.6", "", "54.5", "", "2", "", "", "201", "1", "1", "125", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "85.8", "86.9", "", "", "", "", "86.7"]} -{"pcdb_id": 15913, "brand_name": "HRM", "model_name": "Wallstar System", "model_qualifier": "15/19 Condensing Eco", "winter_efficiency_pct": 83.2, "summer_efficiency_pct": 75.4, "comparative_hot_water_efficiency_pct": 55.1, "output_kw_max": 19.0, "final_year_of_manufacture": null, "raw": ["015913", "000098", "0", "2012/Mar/27 10:12", "HRM Boilers", "HRM", "Wallstar System", "15/19 Condensing Eco", "", "2007", "current", "4", "2", "1", "1", "0", "", "", "2", "2", "2", "15", "19", "", "", "83.2", "75.4", "", "55.1", "", "2", "", "", "201", "1", "1", "125", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "86.0", "88.2", "", "", "", "", "87.8"]} -{"pcdb_id": 15914, "brand_name": "HRM", "model_name": "Wallstar System", "model_qualifier": "15/19 Condensing EOGB", "winter_efficiency_pct": 82.4, "summer_efficiency_pct": 74.6, "comparative_hot_water_efficiency_pct": 54.5, "output_kw_max": 19.0, "final_year_of_manufacture": null, "raw": ["015914", "000098", "0", "2012/Mar/27 10:12", "HRM Boilers", "HRM", "Wallstar System", "15/19 Condensing EOGB", "", "2007", "current", "4", "2", "1", "1", "0", "", "", "2", "2", "2", "15", "19", "", "", "82.4", "74.6", "", "54.5", "", "2", "", "", "201", "1", "1", "125", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "85.8", "86.9", "", "", "", "", "86.7"]} -{"pcdb_id": 15915, "brand_name": "HRM", "model_name": "X-Ternal", "model_qualifier": "15/19 Condensing Eco", "winter_efficiency_pct": 83.2, "summer_efficiency_pct": 75.4, "comparative_hot_water_efficiency_pct": 55.1, "output_kw_max": 18.7, "final_year_of_manufacture": null, "raw": ["015915", "000098", "0", "2012/Mar/27 10:12", "HRM Boilers", "HRM", "X-Ternal", "15/19 Condensing Eco", "", "2007", "current", "4", "2", "2", "1", "0", "", "", "2", "2", "2", "15", "18.7", "", "", "83.2", "75.4", "", "55.1", "", "2", "", "", "201", "1", "1", "125", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "86.0", "88.2", "", "", "", "", "87.8"]} -{"pcdb_id": 15916, "brand_name": "HRM", "model_name": "X-Ternal", "model_qualifier": "15/19 Condensing EOGB", "winter_efficiency_pct": 82.4, "summer_efficiency_pct": 74.6, "comparative_hot_water_efficiency_pct": 54.5, "output_kw_max": 18.7, "final_year_of_manufacture": null, "raw": ["015916", "000098", "0", "2012/Mar/27 10:12", "HRM Boilers", "HRM", "X-Ternal", "15/19 Condensing EOGB", "", "2007", "current", "4", "2", "2", "1", "0", "", "", "2", "2", "2", "15", "18.7", "", "", "82.4", "74.6", "", "54.5", "", "2", "", "", "201", "1", "1", "125", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "85.8", "86.9", "", "", "", "", "86.7"]} -{"pcdb_id": 15917, "brand_name": "HRM", "model_name": "Wallstar", "model_qualifier": "20/24 Condensing Eco", "winter_efficiency_pct": 82.4, "summer_efficiency_pct": 74.6, "comparative_hot_water_efficiency_pct": 54.5, "output_kw_max": 24.0, "final_year_of_manufacture": null, "raw": ["015917", "000098", "0", "2012/Mar/27 10:12", "HRM Boilers", "HRM", "Wallstar", "20/24 Condensing Eco", "", "2007", "current", "4", "2", "1", "1", "0", "", "", "2", "2", "2", "20", "24", "", "", "82.4", "74.6", "", "54.5", "", "2", "", "", "201", "1", "1", "125", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "86.1", "86.5", "", "", "", "", "86.4"]} -{"pcdb_id": 15919, "brand_name": "HRM", "model_name": "Wallstar", "model_qualifier": "20/24 Condensing EOGB", "winter_efficiency_pct": 82.4, "summer_efficiency_pct": 74.6, "comparative_hot_water_efficiency_pct": 54.5, "output_kw_max": 24.0, "final_year_of_manufacture": null, "raw": ["015919", "000098", "0", "2012/Mar/27 10:12", "HRM Boilers", "HRM", "Wallstar", "20/24 Condensing EOGB", "", "2007", "current", "4", "2", "1", "1", "0", "", "", "2", "2", "2", "20", "24", "", "", "82.4", "74.6", "", "54.5", "", "2", "", "", "201", "1", "1", "125", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "85.4", "87.2", "", "", "", "", "86.9"]} -{"pcdb_id": 15921, "brand_name": "Grant", "model_name": "Vortex Eco Wall Hung 12-16", "model_qualifier": "", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 81.3, "comparative_hot_water_efficiency_pct": 59.4, "output_kw_max": 16.0, "final_year_of_manufacture": null, "raw": ["015921", "000048", "0", "2012/Mar/27 10:12", "Grant Engineering (UK)", "Grant", "Vortex Eco Wall Hung 12-16", "", "", "2008", "current", "4", "2", "1", "1", "0", "", "", "2", "3", "2", "12", "16", "", "", "89.1", "81.3", "", "59.4", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "93.1", "96.7", "", "", "", "", "96.0"]} -{"pcdb_id": 15922, "brand_name": "Grant", "model_name": "Vortex Eco Wall Hung 16-21", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 59.2, "output_kw_max": 21.0, "final_year_of_manufacture": null, "raw": ["015922", "000048", "0", "2012/Mar/27 10:12", "Grant Engineering (UK)", "Grant", "Vortex Eco Wall Hung 16-21", "", "", "2008", "current", "4", "2", "1", "1", "0", "", "", "2", "3", "2", "16", "21", "", "", "88.8", "81.0", "", "59.2", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.8", "96.9", "", "", "", "", "95.7"]} -{"pcdb_id": 15923, "brand_name": "Grant", "model_name": "Vortex Eco Wall Hung System 12-16", "model_qualifier": "", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 81.3, "comparative_hot_water_efficiency_pct": 59.4, "output_kw_max": 21.0, "final_year_of_manufacture": null, "raw": ["015923", "000048", "0", "2012/Mar/27 10:12", "Grant Engineering (UK)", "Grant", "Vortex Eco Wall Hung System 12-16", "", "", "2008", "current", "4", "2", "1", "1", "0", "", "", "2", "3", "2", "16", "21", "", "", "89.1", "81.3", "", "59.4", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "93.1", "96.7", "", "", "", "", "96.0"]} -{"pcdb_id": 15924, "brand_name": "Grant", "model_name": "Vortex Eco Wall Hung System 16-21", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 59.2, "output_kw_max": 21.0, "final_year_of_manufacture": null, "raw": ["015924", "000048", "0", "2012/Mar/27 10:12", "Grant Engineering (UK)", "Grant", "Vortex Eco Wall Hung System 16-21", "", "", "2008", "current", "4", "2", "1", "1", "0", "", "", "2", "3", "2", "16", "21", "", "", "88.8", "81.0", "", "59.2", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.8", "96.9", "", "", "", "", "95.7"]} -{"pcdb_id": 15925, "brand_name": "Grant", "model_name": "Vortex Eco Wall Hung External 12-16", "model_qualifier": "", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 81.3, "comparative_hot_water_efficiency_pct": 59.4, "output_kw_max": 16.0, "final_year_of_manufacture": null, "raw": ["015925", "000048", "0", "2012/Mar/27 10:12", "Grant Engineering (UK)", "Grant", "Vortex Eco Wall Hung External 12-16", "", "", "2008", "current", "4", "2", "2", "1", "0", "", "", "2", "3", "2", "12", "16", "", "", "89.1", "81.3", "", "59.4", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "93.1", "96.7", "", "", "", "", "96.0"]} -{"pcdb_id": 15926, "brand_name": "Grant", "model_name": "Vortex Eco Wall Hung External 16-21", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 59.2, "output_kw_max": 21.0, "final_year_of_manufacture": null, "raw": ["015926", "000048", "0", "2012/Mar/27 10:12", "Grant Engineering (UK)", "Grant", "Vortex Eco Wall Hung External 16-21", "", "", "2008", "current", "4", "2", "2", "1", "0", "", "", "2", "3", "2", "16", "21", "", "", "88.8", "81.0", "", "59.2", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.8", "96.9", "", "", "", "", "95.7"]} -{"pcdb_id": 15927, "brand_name": "Grant", "model_name": "Vortex Eco Wall Hung External System 12-16", "model_qualifier": "", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 81.3, "comparative_hot_water_efficiency_pct": 59.4, "output_kw_max": 16.0, "final_year_of_manufacture": null, "raw": ["015927", "000048", "0", "2012/Mar/27 10:12", "Grant Engineering (UK)", "Grant", "Vortex Eco Wall Hung External System 12-16", "", "", "2008", "current", "4", "2", "2", "1", "0", "", "", "2", "3", "2", "12", "16", "", "", "89.1", "81.3", "", "59.4", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "93.1", "96.7", "", "", "", "", "96.0"]} -{"pcdb_id": 15928, "brand_name": "Grant", "model_name": "Vortex Eco Wall Hung External System 16-21", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 59.2, "output_kw_max": 21.0, "final_year_of_manufacture": null, "raw": ["015928", "000048", "0", "2012/Mar/27 10:12", "Grant Engineering (UK)", "Grant", "Vortex Eco Wall Hung External System 16-21", "", "", "2008", "current", "4", "2", "2", "1", "0", "", "", "2", "3", "2", "16", "21", "", "", "88.8", "81.0", "", "59.2", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.8", "96.9", "", "", "", "", "95.7"]} -{"pcdb_id": 15929, "brand_name": "Grant", "model_name": "Vortex Eco", "model_qualifier": "Utility 15-21", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 20.7, "final_year_of_manufacture": null, "raw": ["015929", "000048", "0", "2012/Mar/27 10:12", "Grant Engineering (UK)", "Grant", "Vortex Eco", "Utility 15-21", "", "2008", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "15", "20.7", "", "", "88.0", "80.2", "", "58.6", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.5", "94.4", "", "", "", "", "93.9"]} -{"pcdb_id": 15930, "brand_name": "Grant", "model_name": "Vortex Eco", "model_qualifier": "Utility 21-26", "winter_efficiency_pct": 87.8, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 25.6, "final_year_of_manufacture": null, "raw": ["015930", "000048", "0", "2012/Mar/27 10:12", "Grant Engineering (UK)", "Grant", "Vortex Eco", "Utility 21-26", "", "2008", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "20.7", "25.6", "", "", "87.8", "80.0", "", "58.4", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.4", "94.4", "", "", "", "", "93.6"]} -{"pcdb_id": 15931, "brand_name": "Grant", "model_name": "Vortex Eco", "model_qualifier": "Utility 26-35", "winter_efficiency_pct": 87.5, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 34.7, "final_year_of_manufacture": null, "raw": ["015931", "000048", "0", "2012/Mar/27 10:12", "Grant Engineering (UK)", "Grant", "Vortex Eco", "Utility 26-35", "", "2008", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "25.6", "34.7", "", "", "87.5", "79.7", "", "58.2", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.3", "93.8", "", "", "", "", "93.1"]} -{"pcdb_id": 15932, "brand_name": "Grant", "model_name": "Vortex Eco", "model_qualifier": "External 15-21", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 20.7, "final_year_of_manufacture": null, "raw": ["015932", "000048", "0", "2012/Mar/27 10:12", "Grant Engineering (UK)", "Grant", "Vortex Eco", "External 15-21", "", "2008", "current", "4", "1", "2", "1", "0", "", "", "2", "3", "2", "15", "20.7", "", "", "88.0", "80.2", "", "58.6", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.5", "94.4", "", "", "", "", "93.9"]} -{"pcdb_id": 15933, "brand_name": "Grant", "model_name": "Vortex Eco", "model_qualifier": "External 21-26", "winter_efficiency_pct": 87.8, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 25.6, "final_year_of_manufacture": null, "raw": ["015933", "000048", "0", "2012/Mar/27 10:12", "Grant Engineering (UK)", "Grant", "Vortex Eco", "External 21-26", "", "2008", "current", "4", "1", "2", "1", "0", "", "", "2", "3", "2", "20.7", "25.6", "", "", "87.8", "80.0", "", "58.4", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.4", "94.4", "", "", "", "", "93.6"]} -{"pcdb_id": 15934, "brand_name": "Grant", "model_name": "Vortex Eco", "model_qualifier": "External 26-35", "winter_efficiency_pct": 87.5, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 34.7, "final_year_of_manufacture": null, "raw": ["015934", "000048", "0", "2012/Mar/27 10:12", "Grant Engineering (UK)", "Grant", "Vortex Eco", "External 26-35", "", "2008", "current", "4", "1", "2", "1", "0", "", "", "2", "3", "2", "25.6", "34.7", "", "", "87.5", "79.7", "", "58.2", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.3", "93.8", "", "", "", "", "93.1"]} -{"pcdb_id": 15935, "brand_name": "Worcester", "model_name": "Greenstar Highflow", "model_qualifier": "440 CDi", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 86.9, "comparative_hot_water_efficiency_pct": 49.0, "output_kw_max": 29.2, "final_year_of_manufacture": 2015, "raw": ["015935", "000035", "0", "2020/Sep/08 10:00", "Bosch Thermotechnology", "Worcester", "Greenstar Highflow", "440 CDi", "47 406 24", "2008", "2015", "1", "1", "1", "2", "0", "", "", "2", "2", "2", "29.2", "29.2", "", "", "88.2", "86.9", "", "49.0", "", "2", "", "", "106", "1", "2", "164", "10", "1", "1", "0", "47", "0", "25", "3", "65", "", "1", "10.7537", "0.4102", "0.0084", "4.47444", "", "", "", "", "", "", "", "", "0305", "", "", "", "", "", "", "", "", "88.6", "97.1", "", "", "", "", "95.5"]} -{"pcdb_id": 15936, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "FS 42 CDi Regular", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 40.8, "final_year_of_manufacture": 2015, "raw": ["015936", "000035", "0", "2020/Sep/08 10:00", "Bosch Thermotechnology", "Worcester", "Greenstar", "FS 42 CDi Regular", "41 406 04", "2008", "2015", "1", "1", "1", "1", "0", "", "", "2", "2", "2", "40.8", "40.8", "", "", "88.1", "79.1", "", "57.8", "", "2", "", "", "102", "1", "2", "80", "9", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.1", "97.0", "", "", "", "", "95.3"]} -{"pcdb_id": 15938, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "FS 42 CDi Regular", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 40.8, "final_year_of_manufacture": 2015, "raw": ["015938", "000035", "0", "2020/Sep/08 10:01", "Bosch Thermotechnology", "Worcester", "Greenstar", "FS 42 CDi Regular", "41 406 06", "2008", "2015", "2", "1", "1", "1", "0", "", "", "2", "2", "2", "40.8", "40.8", "", "", "89.1", "80.1", "", "58.5", "", "2", "1", "", "102", "1", "2", "80", "9", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.1", "99.2", "", "", "", "", "97.5"]} -{"pcdb_id": 15939, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "FS 30 CDi Regular", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 30.0, "final_year_of_manufacture": 2015, "raw": ["015939", "000035", "0", "2020/Sep/08 10:01", "Bosch Thermotechnology", "Worcester", "Greenstar", "FS 30 CDi Regular", "41 406 03", "2008", "2015", "1", "1", "1", "1", "0", "", "", "2", "2", "2", "30", "30", "", "", "88.2", "79.2", "", "57.9", "", "2", "", "", "102", "1", "2", "60", "9", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.6", "97.1", "", "", "", "", "95.5"]} -{"pcdb_id": 15940, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "FS 30 CDi Regular", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 30.0, "final_year_of_manufacture": 2015, "raw": ["015940", "000035", "0", "2020/Sep/08 10:01", "Bosch Thermotechnology", "Worcester", "Greenstar", "FS 30 CDi Regular", "41 406 05", "2008", "2015", "2", "1", "1", "1", "0", "", "", "2", "2", "2", "30", "30", "", "", "89.2", "80.2", "", "58.6", "", "2", "1", "", "102", "1", "2", "60", "9", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.5", "99.3", "", "", "", "", "97.6"]} -{"pcdb_id": 15941, "brand_name": "Worcester", "model_name": "Greenstar Highflow", "model_qualifier": "550 CDi", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 86.9, "comparative_hot_water_efficiency_pct": 49.1, "output_kw_max": 30.6, "final_year_of_manufacture": 2015, "raw": ["015941", "000035", "0", "2020/Sep/08 10:01", "Bosch Thermotechnology", "Worcester", "Greenstar Highflow", "550 CDi", "47 406 25", "2008", "2015", "1", "1", "1", "2", "0", "", "", "2", "2", "2", "30.6", "30.6", "", "", "88.2", "86.9", "", "49.1", "", "2", "", "", "106", "1", "2", "206", "10", "1", "1", "0", "47", "0", "25", "3", "65", "", "1", "10.7237", "0.3495", "0.007", "4.4537", "", "", "", "", "", "0", "0", "", "0305", "", "", "", "", "", "", "", "", "88.6", "97.1", "", "", "", "", "95.5"]} -{"pcdb_id": 15942, "brand_name": "Worcester", "model_name": "Greenstar Highflow", "model_qualifier": "550 CDi", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 81.9, "comparative_hot_water_efficiency_pct": 44.3, "output_kw_max": 30.6, "final_year_of_manufacture": 2015, "raw": ["015942", "000035", "0", "2024/Jan/31 10:17", "Bosch Thermotechnology", "Worcester", "Greenstar Highflow", "550 CDi", "47 406 27", "2008", "2015", "2", "1", "1", "2", "0", "", "", "2", "2", "2", "30.6", "30.6", "", "", "89.2", "81.9", "", "44.3", "", "2", "1", "", "106", "1", "2", "206", "10", "1", "1", "0", "47", "0", "25", "3", "65", "", "0", "", "", "", "", "", "", "", "", "", "0", "0", "", "8305", "", "", "", "", "", "", "", "", "90.5", "99.3", "", "", "", "", "97.6"]} -{"pcdb_id": 15943, "brand_name": "Worcester", "model_name": "Greenstar Highflow", "model_qualifier": "440 CDi", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 81.9, "comparative_hot_water_efficiency_pct": 44.3, "output_kw_max": 29.2, "final_year_of_manufacture": 2015, "raw": ["015943", "000035", "0", "2024/Jan/31 10:17", "Bosch Thermotechnology", "Worcester", "Greenstar Highflow", "440 CDi", "47 406 26", "2008", "2015", "2", "1", "1", "2", "0", "", "", "2", "2", "2", "29.2", "29.2", "", "", "89.2", "81.9", "", "44.3", "", "2", "1", "", "106", "1", "2", "164", "10", "1", "1", "0", "47", "0", "25", "3", "65", "", "0", "", "", "", "", "", "", "", "", "", "0", "0", "", "8305", "", "", "", "", "", "", "", "", "90.5", "99.3", "", "", "", "", "97.6"]} -{"pcdb_id": 15944, "brand_name": "HRM", "model_name": "Wallstar", "model_qualifier": "Combi", "winter_efficiency_pct": 85.9, "summer_efficiency_pct": 78.5, "comparative_hot_water_efficiency_pct": 55.2, "output_kw_max": 24.0, "final_year_of_manufacture": null, "raw": ["015944", "000098", "0", "2008/Sep/30 08:09", "HRM Boilers", "HRM", "Wallstar", "Combi", "", "2008", "current", "4", "2", "1", "2", "0", "", "", "2", "2", "2", "18", "24", "", "", "85.9", "78.5", "", "55.2", "", "2", "", "", "202", "1", "1", "125", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "89.4", "90.1", "", "", "", "", "90.0"]} -{"pcdb_id": 15945, "brand_name": "Firebird", "model_name": "Enviromax Popular C20kW", "model_qualifier": "", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 81.2, "comparative_hot_water_efficiency_pct": 59.3, "output_kw_max": 20.0, "final_year_of_manufacture": null, "raw": ["015945", "000047", "0", "2012/Mar/27 10:12", "Firebird Boilers", "Firebird", "Enviromax Popular C20kW", "", "", "2008", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "15", "20", "", "", "89.0", "81.2", "", "59.3", "", "2", "", "", "201", "1", "1", "38", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "93.3", "96.2", "", "", "", "", "95.7"]} -{"pcdb_id": 15947, "brand_name": "Ariston", "model_name": "Clas HE R 24", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 24.1, "final_year_of_manufacture": null, "raw": ["015947", "000080", "0", "2015/Apr/09 12:40", "Merloni TermoSanitari", "Ariston", "Clas HE R 24", "", "41-116-32", "2008", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24.1", "24.1", "", "", "88.3", "79.3", "", "57.9", "", "2", "", "", "102", "1", "2", "144", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "97.3", "", "", "", "", "95.6"]} -{"pcdb_id": 15948, "brand_name": "Ariston", "model_name": "Clas HE R 18", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 17.6, "final_year_of_manufacture": 2013, "raw": ["015948", "000080", "0", "2013/Nov/04 15:24", "Merloni TermoSanitari", "Ariston", "Clas HE R 18", "", "41-116-31", "2008", "2013", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "17.6", "17.6", "", "", "88.6", "79.6", "", "58.1", "", "2", "", "", "102", "1", "2", "142", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "98.2", "", "", "", "", "96.3"]} -{"pcdb_id": 15949, "brand_name": "Ariston", "model_name": "Clas HE R 12", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 11.7, "final_year_of_manufacture": 2013, "raw": ["015949", "000080", "0", "2013/Nov/04 15:25", "Merloni TermoSanitari", "Ariston", "Clas HE R 12", "", "41-116-30", "2008", "2013", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "11.7", "11.7", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "135", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "97.9", "", "", "", "", "96.0"]} -{"pcdb_id": 15950, "brand_name": "Biasi", "model_name": "Riva Advance HE", "model_qualifier": "M110B.24SR/C", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 25.1, "final_year_of_manufacture": null, "raw": ["015950", "000208", "0", "2013/Feb/27 12:41", "Biasi", "Biasi", "Riva Advance HE", "M110B.24SR/C", "41-583-07", "2008", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "25.1", "25.1", "", "", "88.5", "79.5", "", "58.0", "", "2", "", "", "102", "1", "2", "108", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.1", "97.9", "", "", "", "", "96.1"]} -{"pcdb_id": 15951, "brand_name": "Biasi", "model_name": "Riva Advance HE", "model_qualifier": "M110B.24SR/C", "winter_efficiency_pct": 89.5, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 58.8, "output_kw_max": 25.1, "final_year_of_manufacture": null, "raw": ["015951", "000208", "0", "2012/Mar/27 10:12", "Biasi", "Biasi", "Riva Advance HE", "M110B.24SR/C", "", "2008", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "25.1", "25.1", "", "", "89.5", "80.5", "", "58.8", "", "2", "1", "", "102", "1", "2", "108", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.1", "100.1", "", "", "", "", "98.2"]} -{"pcdb_id": 15952, "brand_name": "Intergas", "model_name": "Combi Compact HRE 36/30", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 87.0, "comparative_hot_water_efficiency_pct": 74.4, "output_kw_max": 26.6, "final_year_of_manufacture": null, "raw": ["015952", "000256", "0", "2014/Dec/01 15:12", "Intergas Verwarming", "Intergas", "Combi Compact HRE 36/30", "", "47-291-03", "2008", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "26.6", "26.6", "", "", "88.5", "87.0", "", "74.4", "", "2", "", "", "104", "1", "2", "130", "1.9", "0", "", "", "0", "0", "", "", "", "", "1", "7.079", "0.05", "0.0009", "0.98426", "", "", "", "", "", "1", "0", "", "0005", "", "", "", "", "", "", "", "", "88.9", "97.6", "", "", "", "", "95.9"]} -{"pcdb_id": 15953, "brand_name": "Firebird", "model_name": "Enviromax Systempac C35kW", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 59.0, "output_kw_max": 35.0, "final_year_of_manufacture": null, "raw": ["015953", "000047", "0", "2012/Mar/27 10:12", "Firebird Boilers", "Firebird", "Enviromax Systempac C35kW", "", "", "2008", "current", "4", "1", "2", "1", "0", "", "", "2", "1", "1", "26", "35", "", "", "88.6", "80.8", "", "59.0", "", "2", "", "", "201", "1", "1", "38", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "93.5", "95.3", "", "", "", "", "95.0"]} -{"pcdb_id": 15954, "brand_name": "Firebird", "model_name": "Enviromax Systempac C26kW", "model_qualifier": "", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 81.2, "comparative_hot_water_efficiency_pct": 59.3, "output_kw_max": 26.0, "final_year_of_manufacture": null, "raw": ["015954", "000047", "0", "2012/Mar/27 10:12", "Firebird Boilers", "Firebird", "Enviromax Systempac C26kW", "", "", "2008", "current", "4", "1", "2", "1", "0", "", "", "2", "1", "1", "15", "26", "", "", "89.0", "81.2", "", "59.3", "", "2", "", "", "201", "1", "1", "38", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "93.2", "96.4", "", "", "", "", "95.8"]} -{"pcdb_id": 15955, "brand_name": "Firebird", "model_name": "Enviromax Systempac C20kW", "model_qualifier": "", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 81.2, "comparative_hot_water_efficiency_pct": 59.3, "output_kw_max": 20.0, "final_year_of_manufacture": null, "raw": ["015955", "000047", "0", "2012/Mar/27 10:12", "Firebird Boilers", "Firebird", "Enviromax Systempac C20kW", "", "", "2008", "current", "4", "1", "2", "1", "0", "", "", "2", "1", "1", "15", "20", "", "", "89.0", "81.2", "", "59.3", "", "2", "", "", "201", "1", "1", "38", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "93.3", "96.2", "", "", "", "", "95.7"]} -{"pcdb_id": 15956, "brand_name": "Firebird", "model_name": "Enviromax Combipac C20kW", "model_qualifier": "", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 82.9, "comparative_hot_water_efficiency_pct": 50.7, "output_kw_max": 20.0, "final_year_of_manufacture": null, "raw": ["015956", "000047", "0", "2024/Jan/31 10:17", "Firebird Boilers", "Firebird", "Enviromax Combipac C20kW", "", "", "2008", "current", "4", "1", "2", "2", "0", "", "", "2", "1", "1", "15", "20", "", "", "89.0", "82.9", "", "50.7", "", "2", "", "", "203", "1", "1", "38", "0", "2", "", "0", "40", "0", "25", "1", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "93.3", "96.2", "", "", "", "", "95.7"]} -{"pcdb_id": 15957, "brand_name": "Firebird", "model_name": "Enviromax Combipac C26kW", "model_qualifier": "", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 82.9, "comparative_hot_water_efficiency_pct": 50.8, "output_kw_max": 26.0, "final_year_of_manufacture": null, "raw": ["015957", "000047", "0", "2024/Jan/31 10:17", "Firebird Boilers", "Firebird", "Enviromax Combipac C26kW", "", "", "2008", "current", "4", "1", "2", "2", "0", "", "", "2", "1", "1", "15", "26", "", "", "89.0", "82.9", "", "50.8", "", "2", "", "", "203", "1", "1", "38", "0", "2", "", "0", "40", "0", "25", "1", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "93.2", "96.4", "", "", "", "", "95.8"]} -{"pcdb_id": 15958, "brand_name": "Firebird", "model_name": "Enviromax Combipac C35kW", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 82.5, "comparative_hot_water_efficiency_pct": 50.5, "output_kw_max": 35.0, "final_year_of_manufacture": null, "raw": ["015958", "000047", "0", "2024/Jan/31 10:17", "Firebird Boilers", "Firebird", "Enviromax Combipac C35kW", "", "", "2008", "current", "4", "1", "2", "2", "0", "", "", "2", "1", "1", "26", "35", "", "", "88.6", "82.5", "", "50.5", "", "2", "", "", "203", "1", "1", "38", "0", "2", "", "0", "40", "0", "25", "1", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "93.5", "95.3", "", "", "", "", "95.0"]} -{"pcdb_id": 15959, "brand_name": "Firebird", "model_name": "Enviromax Combi C20kW", "model_qualifier": "", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 82.9, "comparative_hot_water_efficiency_pct": 50.7, "output_kw_max": 20.0, "final_year_of_manufacture": null, "raw": ["015959", "000047", "0", "2024/Jan/31 10:17", "Firebird Boilers", "Firebird", "Enviromax Combi C20kW", "", "", "2008", "current", "4", "1", "1", "2", "0", "", "", "2", "3", "1", "15", "20", "", "", "89.0", "82.9", "", "50.7", "", "2", "", "", "203", "1", "1", "38", "0", "2", "", "0", "40", "0", "25", "1", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "93.3", "96.2", "", "", "", "", "95.7"]} -{"pcdb_id": 15960, "brand_name": "Firebird", "model_name": "Enviromax Combi C26kW", "model_qualifier": "", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 82.9, "comparative_hot_water_efficiency_pct": 50.8, "output_kw_max": 26.0, "final_year_of_manufacture": null, "raw": ["015960", "000047", "0", "2024/Jan/31 10:17", "Firebird Boilers", "Firebird", "Enviromax Combi C26kW", "", "", "2008", "current", "4", "1", "1", "2", "0", "", "", "2", "3", "1", "15", "26", "", "", "89.0", "82.9", "", "50.8", "", "2", "", "", "203", "1", "1", "38", "0", "2", "", "0", "40", "0", "25", "1", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "93.2", "96.4", "", "", "", "", "95.8"]} -{"pcdb_id": 15961, "brand_name": "Firebird", "model_name": "Enviromax Combi C35kW", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 82.5, "comparative_hot_water_efficiency_pct": 50.5, "output_kw_max": 35.0, "final_year_of_manufacture": null, "raw": ["015961", "000047", "0", "2024/Jan/31 10:17", "Firebird Boilers", "Firebird", "Enviromax Combi C35kW", "", "", "2008", "current", "4", "1", "1", "2", "0", "", "", "2", "3", "1", "26", "35", "", "", "88.6", "82.5", "", "50.5", "", "2", "", "", "203", "1", "1", "38", "0", "2", "", "0", "40", "0", "25", "1", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "93.5", "95.3", "", "", "", "", "95.0"]} -{"pcdb_id": 15962, "brand_name": "Firebird", "model_name": "Enviromax System C20kW", "model_qualifier": "", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 81.2, "comparative_hot_water_efficiency_pct": 59.3, "output_kw_max": 20.0, "final_year_of_manufacture": null, "raw": ["015962", "000047", "0", "2012/Mar/27 10:12", "Firebird Boilers", "Firebird", "Enviromax System C20kW", "", "", "2008", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "15", "20", "", "", "89.0", "81.2", "", "59.3", "", "2", "", "", "201", "1", "1", "38", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "93.3", "96.2", "", "", "", "", "95.7"]} -{"pcdb_id": 15963, "brand_name": "Firebird", "model_name": "Enviromax System C26kW", "model_qualifier": "", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 81.2, "comparative_hot_water_efficiency_pct": 59.3, "output_kw_max": 26.0, "final_year_of_manufacture": null, "raw": ["015963", "000047", "0", "2012/Mar/27 10:12", "Firebird Boilers", "Firebird", "Enviromax System C26kW", "", "", "2008", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "15", "26", "", "", "89.0", "81.2", "", "59.3", "", "2", "", "", "201", "1", "1", "38", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "93.2", "96.4", "", "", "", "", "95.8"]} -{"pcdb_id": 15964, "brand_name": "Firebird", "model_name": "Enviromax System C35kW", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 59.0, "output_kw_max": 35.0, "final_year_of_manufacture": null, "raw": ["015964", "000047", "0", "2012/Mar/27 10:12", "Firebird Boilers", "Firebird", "Enviromax System C35kW", "", "", "2008", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "26", "35", "", "", "88.6", "80.8", "", "59.0", "", "2", "", "", "201", "1", "1", "38", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "93.5", "95.3", "", "", "", "", "95.0"]} -{"pcdb_id": 15965, "brand_name": "Firebird", "model_name": "Enviromax Popular C26kW", "model_qualifier": "", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 81.2, "comparative_hot_water_efficiency_pct": 59.3, "output_kw_max": 26.0, "final_year_of_manufacture": null, "raw": ["015965", "000047", "0", "2012/Mar/27 10:12", "Firebird Boilers", "Firebird", "Enviromax Popular C26kW", "", "", "2008", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "15", "26", "", "", "89.0", "81.2", "", "59.3", "", "2", "", "", "201", "1", "1", "38", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "93.2", "96.4", "", "", "", "", "95.8"]} -{"pcdb_id": 15966, "brand_name": "Firebird", "model_name": "Enviromax Popular C35kW", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 59.0, "output_kw_max": 35.0, "final_year_of_manufacture": null, "raw": ["015966", "000047", "0", "2012/Mar/27 10:12", "Firebird Boilers", "Firebird", "Enviromax Popular C35kW", "", "", "2008", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "26", "35", "", "", "88.6", "80.8", "", "59.0", "", "2", "", "", "201", "1", "1", "38", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "93.5", "95.3", "", "", "", "", "95.0"]} -{"pcdb_id": 15967, "brand_name": "Firebird", "model_name": "Enviromax Heatpac C20kW", "model_qualifier": "", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 81.2, "comparative_hot_water_efficiency_pct": 59.3, "output_kw_max": 20.0, "final_year_of_manufacture": null, "raw": ["015967", "000047", "0", "2012/Mar/27 10:12", "Firebird Boilers", "Firebird", "Enviromax Heatpac C20kW", "", "", "2008", "current", "4", "1", "2", "1", "0", "", "", "2", "1", "1", "15", "20", "", "", "89.0", "81.2", "", "59.3", "", "2", "", "", "201", "1", "1", "38", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "93.3", "96.2", "", "", "", "", "95.7"]} -{"pcdb_id": 15968, "brand_name": "Firebird", "model_name": "Enviromax Heatpac C26kW", "model_qualifier": "", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 81.2, "comparative_hot_water_efficiency_pct": 59.3, "output_kw_max": 26.0, "final_year_of_manufacture": null, "raw": ["015968", "000047", "0", "2012/Mar/27 10:12", "Firebird Boilers", "Firebird", "Enviromax Heatpac C26kW", "", "", "2008", "current", "4", "1", "2", "1", "0", "", "", "2", "1", "1", "15", "26", "", "", "89.0", "81.2", "", "59.3", "", "2", "", "", "201", "1", "1", "38", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "93.2", "96.4", "", "", "", "", "95.8"]} -{"pcdb_id": 15969, "brand_name": "Firebird", "model_name": "Enviromax Heatpac C35kW", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 59.0, "output_kw_max": 35.0, "final_year_of_manufacture": null, "raw": ["015969", "000047", "0", "2012/Mar/27 10:12", "Firebird Boilers", "Firebird", "Enviromax Heatpac C35kW", "", "", "2008", "current", "4", "1", "2", "1", "0", "", "", "2", "1", "1", "26", "35", "", "", "88.6", "80.8", "", "59.0", "", "2", "", "", "201", "1", "1", "38", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "93.5", "95.3", "", "", "", "", "95.0"]} -{"pcdb_id": 15970, "brand_name": "Firebird", "model_name": "Enviromax Utility C35kW", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 59.0, "output_kw_max": 35.0, "final_year_of_manufacture": null, "raw": ["015970", "000047", "0", "2012/Jun/28 11:04", "Firebird Boilers", "Firebird", "Enviromax Utility C35kW", "", "", "2008", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "26", "35", "", "", "88.6", "80.8", "", "59.0", "", "2", "", "", "201", "1", "1", "38", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "93.5", "95.3", "", "", "", "", "95.0"]} -{"pcdb_id": 15971, "brand_name": "Firebird", "model_name": "Enviromax Utility C26kW", "model_qualifier": "", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 81.2, "comparative_hot_water_efficiency_pct": 59.3, "output_kw_max": 26.0, "final_year_of_manufacture": null, "raw": ["015971", "000047", "0", "2012/Jun/28 11:04", "Firebird Boilers", "Firebird", "Enviromax Utility C26kW", "", "", "2008", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "15", "26", "", "", "89.0", "81.2", "", "59.3", "", "2", "", "", "201", "1", "1", "38", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "93.2", "96.4", "", "", "", "", "95.8"]} -{"pcdb_id": 15972, "brand_name": "Firebird", "model_name": "Enviromax Utility C20kW", "model_qualifier": "", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 81.2, "comparative_hot_water_efficiency_pct": 59.3, "output_kw_max": 20.0, "final_year_of_manufacture": null, "raw": ["015972", "000047", "0", "2012/Jun/28 11:04", "Firebird Boilers", "Firebird", "Enviromax Utility C20kW", "", "", "2008", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "15", "20", "", "", "89.0", "81.2", "", "59.3", "", "2", "", "", "201", "1", "1", "38", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "93.3", "96.2", "", "", "", "", "95.7"]} -{"pcdb_id": 15973, "brand_name": "Firebird", "model_name": "Enviromax Kitchen C20kW", "model_qualifier": "", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 81.2, "comparative_hot_water_efficiency_pct": 59.3, "output_kw_max": 20.0, "final_year_of_manufacture": null, "raw": ["015973", "000047", "0", "2012/Mar/27 10:12", "Firebird Boilers", "Firebird", "Enviromax Kitchen C20kW", "", "", "2008", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "15", "20", "", "", "89.0", "81.2", "", "59.3", "", "2", "", "", "201", "1", "1", "38", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "93.3", "96.2", "", "", "", "", "95.7"]} -{"pcdb_id": 15974, "brand_name": "Firebird", "model_name": "Enviromax Kitchen C26kW", "model_qualifier": "", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 81.2, "comparative_hot_water_efficiency_pct": 59.3, "output_kw_max": 26.0, "final_year_of_manufacture": null, "raw": ["015974", "000047", "0", "2012/Mar/27 10:12", "Firebird Boilers", "Firebird", "Enviromax Kitchen C26kW", "", "", "2008", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "15", "26", "", "", "89.0", "81.2", "", "59.3", "", "2", "", "", "201", "1", "1", "38", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "93.2", "96.4", "", "", "", "", "95.8"]} -{"pcdb_id": 15975, "brand_name": "Firebird", "model_name": "Enviromax Kitchen C35kW", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 59.0, "output_kw_max": 35.0, "final_year_of_manufacture": null, "raw": ["015975", "000047", "0", "2012/Mar/27 10:12", "Firebird Boilers", "Firebird", "Enviromax Kitchen C35kW", "", "", "2008", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "26", "35", "", "", "88.6", "80.8", "", "59.0", "", "2", "", "", "201", "1", "1", "38", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "93.5", "95.3", "", "", "", "", "95.0"]} -{"pcdb_id": 15977, "brand_name": "Viessmann", "model_name": "Vitodens 100 W WB1B", "model_qualifier": "26kW Combi Boiler", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 62.3, "output_kw_max": 23.7, "final_year_of_manufacture": 2012, "raw": ["015977", "000033", "0", "2010/Sep/29 12:25", "Viessmann", "Viessmann", "Vitodens 100 W WB1B", "26kW Combi Boiler", "GC No 47-819-18", "2008", "2012", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "23.7", "23.7", "", "", "88.4", "79.8", "", "62.3", "", "2", "", "", "104", "1", "2", "111", "7", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "", "0005", "", "", "", "", "", "", "", "", "87.8", "97.8", "", "", "", "", "95.9"]} -{"pcdb_id": 15978, "brand_name": "Viessmann", "model_name": "Vitodens 100 W WB1B", "model_qualifier": "26kw Combi Boiler", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 63.1, "output_kw_max": 23.7, "final_year_of_manufacture": 2012, "raw": ["015978", "000033", "0", "2008/Nov/24 09:32", "Viessmann", "Viessmann", "Vitodens 100 W WB1B", "26kw Combi Boiler", "", "2008", "2012", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "23.7", "23.7", "", "", "89.4", "80.8", "", "63.1", "", "2", "1", "", "104", "1", "2", "111", "7", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "", "0005", "", "", "", "", "", "", "", "", "89.8", "100.0", "", "", "", "", "98.1"]} -{"pcdb_id": 15979, "brand_name": "Viessmann", "model_name": "Vitodens 100 W WB1B", "model_qualifier": "30kW Combi Boiler", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 62.5, "output_kw_max": 23.7, "final_year_of_manufacture": 2012, "raw": ["015979", "000033", "0", "2010/Sep/29 12:25", "Viessmann", "Viessmann", "Vitodens 100 W WB1B", "30kW Combi Boiler", "GC No. 47-819-19", "2008", "2012", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "23.7", "23.7", "", "", "88.7", "80.1", "", "62.5", "", "2", "", "", "104", "1", "2", "125", "7", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "", "0005", "", "", "", "", "", "", "", "", "88.5", "98.3", "", "", "", "", "96.4"]} -{"pcdb_id": 15980, "brand_name": "Viessmann", "model_name": "Vitodens 100 W WB1B", "model_qualifier": "30 kW Combi Boiler", "winter_efficiency_pct": 89.7, "summer_efficiency_pct": 81.1, "comparative_hot_water_efficiency_pct": 63.3, "output_kw_max": 23.7, "final_year_of_manufacture": 2012, "raw": ["015980", "000033", "0", "2008/Nov/24 09:34", "Viessmann", "Viessmann", "Vitodens 100 W WB1B", "30 kW Combi Boiler", "", "2008", "2012", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "23.7", "23.7", "", "", "89.7", "81.1", "", "63.3", "", "2", "1", "", "104", "1", "2", "125", "7", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "", "0005", "", "", "", "", "", "", "", "", "90.4", "100.5", "", "", "", "", "98.6"]} -{"pcdb_id": 15981, "brand_name": "Viessmann", "model_name": "Vitodens 100 W WB1B", "model_qualifier": "35kW Combi Boiler", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 62.5, "output_kw_max": 23.7, "final_year_of_manufacture": 2012, "raw": ["015981", "000033", "0", "2010/Sep/29 12:25", "Viessmann", "Viessmann", "Vitodens 100 W WB1B", "35kW Combi Boiler", "GC No 47-819-20", "2008", "2012", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "23.7", "23.7", "", "", "88.7", "80.1", "", "62.5", "", "2", "", "", "104", "1", "2", "125", "7", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "", "0005", "", "", "", "", "", "", "", "", "88.5", "98.3", "", "", "", "", "96.4"]} -{"pcdb_id": 15982, "brand_name": "Viessmann", "model_name": "Vitodens 100 W WB1B", "model_qualifier": "35kW Combi Boiler", "winter_efficiency_pct": 89.7, "summer_efficiency_pct": 81.1, "comparative_hot_water_efficiency_pct": 63.3, "output_kw_max": 23.7, "final_year_of_manufacture": 2012, "raw": ["015982", "000033", "0", "2008/Nov/24 09:36", "Viessmann", "Viessmann", "Vitodens 100 W WB1B", "35kW Combi Boiler", "", "2008", "2012", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "23.7", "23.7", "", "", "89.7", "81.1", "", "63.3", "", "2", "1", "", "104", "1", "2", "125", "7", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "", "0005", "", "", "", "", "", "", "", "", "90.4", "100.5", "", "", "", "", "98.6"]} -{"pcdb_id": 15983, "brand_name": "Viessmann", "model_name": "Vitodens 100 W WB1B", "model_qualifier": "26kW System Boiler", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 78.9, "comparative_hot_water_efficiency_pct": 57.6, "output_kw_max": 23.7, "final_year_of_manufacture": 2012, "raw": ["015983", "000033", "0", "2012/Aug/28 09:57", "Viessmann", "Viessmann", "Vitodens 100 W WB1B", "26kW System Boiler", "GC No 41-819-12", "2008", "2012", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "23.7", "23.7", "", "", "87.9", "78.9", "", "57.6", "", "2", "", "", "102", "1", "2", "107", "7", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.1", "96.4", "", "", "", "", "94.8"]} -{"pcdb_id": 15984, "brand_name": "Viessmann", "model_name": "Vitodens 100 W WB1B", "model_qualifier": "26kW System Boiler", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 23.7, "final_year_of_manufacture": 2012, "raw": ["015984", "000033", "0", "2012/Mar/27 10:12", "Viessmann", "Viessmann", "Vitodens 100 W WB1B", "26kW System Boiler", "", "2008", "2012", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "23.7", "23.7", "", "", "88.9", "79.9", "", "58.3", "", "2", "1", "", "102", "1", "2", "107", "7", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.1", "98.5", "", "", "", "", "96.9"]} -{"pcdb_id": 15985, "brand_name": "Viessmann", "model_name": "Vitodens 100 W WB1B", "model_qualifier": "30kW System Boiler", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 27.3, "final_year_of_manufacture": 2012, "raw": ["015985", "000033", "0", "2012/Aug/28 09:57", "Viessmann", "Viessmann", "Vitodens 100 W WB1B", "30kW System Boiler", "GC No. 41-819-13", "2008", "2012", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "27.3", "27.3", "", "", "88.7", "79.7", "", "58.2", "", "2", "", "", "102", "1", "2", "111", "7", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "98.4", "", "", "", "", "96.5"]} -{"pcdb_id": 15986, "brand_name": "Viessmann", "model_name": "Vitodens 100 W WB1B", "model_qualifier": "30kW System Boiler", "winter_efficiency_pct": 89.7, "summer_efficiency_pct": 80.7, "comparative_hot_water_efficiency_pct": 58.9, "output_kw_max": 27.3, "final_year_of_manufacture": 2012, "raw": ["015986", "000033", "0", "2012/Mar/27 10:12", "Viessmann", "Viessmann", "Vitodens 100 W WB1B", "30kW System Boiler", "", "2008", "2012", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "27.3", "27.3", "", "", "89.7", "80.7", "", "58.9", "", "2", "1", "", "102", "1", "2", "111", "7", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.3", "100.6", "", "", "", "", "98.6"]} -{"pcdb_id": 15987, "brand_name": "Viessmann", "model_name": "Vitodens 100 W WB1B", "model_qualifier": "35kW System Boiler", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 31.9, "final_year_of_manufacture": 2012, "raw": ["015987", "000033", "0", "2012/Aug/28 09:57", "Viessmann", "Viessmann", "Vitodens 100 W WB1B", "35kW System Boiler", "GC No. 41-819-14", "2008", "2012", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "31.9", "31.9", "", "", "88.8", "79.8", "", "58.3", "", "2", "", "", "102", "1", "2", "154", "7", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.6", "98.6", "", "", "", "", "96.7"]} -{"pcdb_id": 15988, "brand_name": "Viessmann", "model_name": "Vitodens 100 W WB1B", "model_qualifier": "35kW System Boiler", "winter_efficiency_pct": 89.8, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 59.0, "output_kw_max": 31.9, "final_year_of_manufacture": 2012, "raw": ["015988", "000033", "0", "2012/Mar/27 10:12", "Viessmann", "Viessmann", "Vitodens 100 W WB1B", "35kW System Boiler", "", "2008", "2012", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "31.9", "31.9", "", "", "89.8", "80.8", "", "59.0", "", "2", "1", "", "102", "1", "2", "154", "7", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.5", "100.8", "", "", "", "", "98.8"]} -{"pcdb_id": 15989, "brand_name": "Viessmann", "model_name": "Vitodens 333", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 81.1, "comparative_hot_water_efficiency_pct": 54.0, "output_kw_max": 24.1, "final_year_of_manufacture": 2012, "raw": ["015989", "000033", "0", "2024/Jan/31 10:17", "Viessmann", "Viessmann", "Vitodens 333", "", "GC No 47-819-07", "2007", "2012", "1", "1", "1", "2", "0", "", "", "2", "2", "2", "24.1", "24.1", "", "", "88.4", "81.1", "", "54.0", "", "2", "", "", "106", "1", "2", "65", "7", "1", "", "0", "86", "0", "50", "5", "60", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "97.8", "", "", "", "", "95.9"]} -{"pcdb_id": 15990, "brand_name": "Viessmann", "model_name": "Vitodens 333", "model_qualifier": "", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 82.1, "comparative_hot_water_efficiency_pct": 54.7, "output_kw_max": 24.1, "final_year_of_manufacture": 2012, "raw": ["015990", "000033", "0", "2024/Jan/31 10:17", "Viessmann", "Viessmann", "Vitodens 333", "", "", "2007", "2012", "2", "1", "1", "2", "0", "", "", "2", "2", "2", "24.1", "24.1", "", "", "89.4", "82.1", "", "54.7", "", "2", "1", "", "106", "1", "2", "65", "7", "1", "", "0", "86", "0", "50", "5", "60", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.8", "100.0", "", "", "", "", "98.1"]} -{"pcdb_id": 15991, "brand_name": "Vaillant", "model_name": "ecoTEC VU GB 466/4-5", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 44.1, "final_year_of_manufacture": 2018, "raw": ["015991", "000031", "0", "2019/Jul/31 15:29", "Vaillant", "Vaillant", "ecoTEC VU GB 466/4-5", "", "GC No. 41-044-058", "2007", "2018", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "44.1", "44.1", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "180", "4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0045", "", "", "", "", "", "", "", "", "88.7", "97.6", "", "", "", "", "95.9"]} -{"pcdb_id": 15993, "brand_name": "Vaillant", "model_name": "ecoTEC VU GB 656/4-5-H", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 63.7, "final_year_of_manufacture": 2018, "raw": ["015993", "000031", "0", "2019/Jul/31 15:32", "Vaillant", "Vaillant", "ecoTEC VU GB 656/4-5-H", "", "GC no 41-044-059", "2007", "2018", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "63.7", "63.7", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "260", "4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0045", "", "", "", "", "", "", "", "", "87.8", "96.9", "", "", "", "", "95.2"]} -{"pcdb_id": 15994, "brand_name": "Halstead", "model_name": "iheat", "model_qualifier": "20", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 19.68, "final_year_of_manufacture": null, "raw": ["015994", "000019", "0", "2012/Mar/27 10:12", "Halstead Boilers", "Halstead", "iheat", "20", "4126025", "2008", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "19.68", "19.68", "", "", "88.1", "79.1", "", "57.8", "", "2", "", "", "102", "1", "2", "150", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.7", "96.9", "", "", "", "", "95.3"]} -{"pcdb_id": 15995, "brand_name": "Halstead", "model_name": "iheat", "model_qualifier": "25c", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 56.0, "output_kw_max": 19.64, "final_year_of_manufacture": null, "raw": ["015995", "000019", "0", "2010/Jan/28 11:55", "Halstead Boilers", "Halstead", "iheat", "25c", "4726016", "2008", "current", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "19.64", "19.64", "", "", "88.2", "79.6", "", "56.0", "", "2", "", "", "104", "1", "2", "150", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.5", "97.0", "", "", "", "", "95.4"]} -{"pcdb_id": 15996, "brand_name": "Halstead", "model_name": "iheat", "model_qualifier": "25s", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 24.53, "final_year_of_manufacture": null, "raw": ["015996", "000019", "0", "2012/Mar/27 10:12", "Halstead Boilers", "Halstead", "iheat", "25s", "4126024", "2008", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "24.53", "24.53", "", "", "88.1", "79.1", "", "57.8", "", "2", "", "", "102", "1", "2", "150", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.4", "96.9", "", "", "", "", "95.3"]} -{"pcdb_id": 15997, "brand_name": "Halstead", "model_name": "iheat", "model_qualifier": "30c", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 55.9, "output_kw_max": 24.45, "final_year_of_manufacture": null, "raw": ["015997", "000019", "0", "2010/Jan/28 11:55", "Halstead Boilers", "Halstead", "iheat", "30c", "4726017", "2008", "current", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "24.45", "24.45", "", "", "88.2", "79.6", "", "55.9", "", "2", "", "", "104", "1", "2", "150", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.1", "97.1", "", "", "", "", "95.4"]} -{"pcdb_id": 15998, "brand_name": "Halstead", "model_name": "iheat", "model_qualifier": "35c", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 55.9, "output_kw_max": 29.31, "final_year_of_manufacture": null, "raw": ["015998", "000019", "0", "2010/Jan/28 11:56", "Halstead Boilers", "Halstead", "iheat", "35c", "4726018", "2008", "current", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "29.31", "29.31", "", "", "88.1", "79.5", "", "55.9", "", "2", "", "", "104", "1", "2", "150", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "97.1", "", "", "", "", "95.4"]} -{"pcdb_id": 15999, "brand_name": "Halstead", "model_name": "Iheat", "model_qualifier": "29c", "winter_efficiency_pct": 85.2, "summer_efficiency_pct": 76.6, "comparative_hot_water_efficiency_pct": 53.9, "output_kw_max": 28.3, "final_year_of_manufacture": null, "raw": ["015999", "000019", "0", "2009/Jan/20 16:27", "Halstead Boilers", "Halstead", "Iheat", "29c", "4726020", "2008", "current", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "28.30", "28.30", "", "", "85.2", "76.6", "", "53.9", "", "2", "", "", "104", "1", "2", "150", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "89.6", "", "", "", "", "89.3"]} -{"pcdb_id": 16005, "brand_name": "Dimplex", "model_name": "OV 18", "model_qualifier": "", "winter_efficiency_pct": 90.2, "summer_efficiency_pct": 81.2, "comparative_hot_water_efficiency_pct": 59.3, "output_kw_max": 18.1, "final_year_of_manufacture": null, "raw": ["016005", "000019", "0", "2012/Mar/27 10:12", "Dimplex", "Dimplex", "OV 18", "", "", "2008", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "18.1", "18.1", "", "", "90.2", "81.2", "", "59.3", "", "2", "1", "", "102", "1", "2", "15.5", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "91.7", "101.3", "", "", "", "", "99.5"]} -{"pcdb_id": 16006, "brand_name": "Dimplex", "model_name": "OV 18", "model_qualifier": "", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 18.1, "final_year_of_manufacture": null, "raw": ["016006", "000019", "0", "2012/Mar/27 10:12", "Dimplex", "Dimplex", "OV 18", "", "GC No. 41-149-04", "2008", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18.1", "18.1", "", "", "89.2", "80.2", "", "58.6", "", "2", "", "", "102", "1", "2", "15.5", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.7", "99.1", "", "", "", "", "97.3"]} -{"pcdb_id": 16007, "brand_name": "Dimplex", "model_name": "OV 32", "model_qualifier": "", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 80.4, "comparative_hot_water_efficiency_pct": 58.7, "output_kw_max": 30.7, "final_year_of_manufacture": null, "raw": ["016007", "000019", "0", "2012/Mar/27 10:12", "Dimplex", "Dimplex", "OV 32", "", "", "2008", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "30.7", "30.7", "", "", "89.4", "80.4", "", "58.7", "", "2", "1", "", "102", "1", "2", "41.4", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.0", "99.8", "", "", "", "", "98.0"]} -{"pcdb_id": 16008, "brand_name": "Dimplex", "model_name": "OV 32", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 30.7, "final_year_of_manufacture": null, "raw": ["016008", "000019", "0", "2012/Mar/27 10:12", "Dimplex", "Dimplex", "OV 32", "", "GC No. 41-149-03", "2008", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "30.7", "30.7", "", "", "88.3", "79.3", "", "58.0", "", "2", "", "", "102", "1", "2", "41.4", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "97.7", "", "", "", "", "95.8"]} -{"pcdb_id": 16009, "brand_name": "Dimplex", "model_name": "Combi 38", "model_qualifier": "", "winter_efficiency_pct": 90.0, "summer_efficiency_pct": 81.4, "comparative_hot_water_efficiency_pct": 57.2, "output_kw_max": 30.0, "final_year_of_manufacture": null, "raw": ["016009", "000019", "0", "2011/Jun/14 10:11", "Dimplex", "Dimplex", "Combi 38", "", "", "2008", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "30", "30", "", "", "90.0", "81.4", "", "57.2", "", "2", "1", "", "104", "1", "2", "127", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.4", "101.3", "", "", "", "", "99.2"]} -{"pcdb_id": 16010, "brand_name": "Dimplex", "model_name": "Combi 38", "model_qualifier": "", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.4, "comparative_hot_water_efficiency_pct": 56.5, "output_kw_max": 30.0, "final_year_of_manufacture": null, "raw": ["016010", "000019", "0", "2011/Jun/30 09:50", "Dimplex", "Dimplex", "Combi 38", "", "GC No. 47-149-01", "2008", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "30", "30", "", "", "89.0", "80.4", "", "56.5", "", "2", "", "", "104", "1", "2", "127", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.4", "99.1", "", "", "", "", "97.1"]} -{"pcdb_id": 16011, "brand_name": "Dimplex", "model_name": "Combi 30", "model_qualifier": "", "winter_efficiency_pct": 89.5, "summer_efficiency_pct": 80.9, "comparative_hot_water_efficiency_pct": 56.9, "output_kw_max": 23.3, "final_year_of_manufacture": null, "raw": ["016011", "000019", "0", "2011/Jun/14 10:11", "Dimplex", "Dimplex", "Combi 30", "", "", "2008", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "23.3", "23.3", "", "", "89.5", "80.9", "", "56.9", "", "2", "1", "", "104", "1", "2", "121", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.9", "100.1", "", "", "", "", "98.2"]} -{"pcdb_id": 16012, "brand_name": "Dimplex", "model_name": "Combi 30", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 56.1, "output_kw_max": 23.3, "final_year_of_manufacture": null, "raw": ["016012", "000019", "0", "2011/Jun/14 10:11", "Dimplex", "Dimplex", "Combi 30", "", "GC No. 47-149-02", "2008", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "23.3", "23.3", "", "", "88.4", "79.8", "", "56.1", "", "2", "", "", "104", "1", "2", "121", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "97.9", "", "", "", "", "96.0"]} -{"pcdb_id": 16013, "brand_name": "Dimplex", "model_name": "Combi 24", "model_qualifier": "", "winter_efficiency_pct": 90.2, "summer_efficiency_pct": 81.6, "comparative_hot_water_efficiency_pct": 57.4, "output_kw_max": 18.0, "final_year_of_manufacture": null, "raw": ["016013", "000019", "0", "2011/Jun/14 10:11", "Dimplex", "Dimplex", "Combi 24", "", "", "2008", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "18", "18", "", "", "90.2", "81.6", "", "57.4", "", "2", "1", "", "104", "1", "2", "96", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.3", "101.9", "", "", "", "", "99.7"]} -{"pcdb_id": 16014, "brand_name": "Dimplex", "model_name": "Combi 24", "model_qualifier": "", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 80.6, "comparative_hot_water_efficiency_pct": 56.7, "output_kw_max": 18.0, "final_year_of_manufacture": null, "raw": ["016014", "000019", "0", "2011/Jun/30 09:50", "Dimplex", "Dimplex", "Combi 24", "", "GC No. 47-149-03", "2008", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "18", "18", "", "", "89.2", "80.6", "", "56.7", "", "2", "", "", "104", "1", "2", "96", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "99.7", "", "", "", "", "97.5"]} -{"pcdb_id": 16015, "brand_name": "Dimplex", "model_name": "System 30", "model_qualifier": "", "winter_efficiency_pct": 90.1, "summer_efficiency_pct": 81.1, "comparative_hot_water_efficiency_pct": 59.3, "output_kw_max": 29.8, "final_year_of_manufacture": null, "raw": ["016015", "000019", "0", "2012/Mar/27 10:12", "Dimplex", "Dimplex", "System 30", "", "", "2008", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "29.8", "29.8", "", "", "90.1", "81.1", "", "59.3", "", "2", "1", "", "102", "1", "2", "123", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.3", "101.7", "", "", "", "", "99.5"]} -{"pcdb_id": 16016, "brand_name": "Dimplex", "model_name": "System 30", "model_qualifier": "", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 29.8, "final_year_of_manufacture": null, "raw": ["016016", "000019", "0", "2012/Mar/27 10:12", "Dimplex", "Dimplex", "System 30", "", "GC No. 41-149-01", "2008", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "29.8", "29.8", "", "", "89.1", "80.1", "", "58.5", "", "2", "", "", "102", "1", "2", "123", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "99.5", "", "", "", "", "97.3"]} -{"pcdb_id": 16017, "brand_name": "Dimplex", "model_name": "System 18", "model_qualifier": "", "winter_efficiency_pct": 90.2, "summer_efficiency_pct": 81.2, "comparative_hot_water_efficiency_pct": 59.3, "output_kw_max": 18.1, "final_year_of_manufacture": null, "raw": ["016017", "000019", "0", "2012/Mar/27 10:12", "Dimplex", "Dimplex", "System 18", "", "", "2008", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "18.1", "18.1", "", "", "90.2", "81.2", "", "59.3", "", "2", "1", "", "102", "1", "2", "98.7", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "91.7", "101.3", "", "", "", "", "99.5"]} -{"pcdb_id": 16018, "brand_name": "Dimplex", "model_name": "System 18", "model_qualifier": "", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 18.1, "final_year_of_manufacture": null, "raw": ["016018", "000019", "0", "2012/Mar/27 10:12", "Dimplex", "Dimplex", "System 18", "", "GC No. 41-149-02", "2008", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18.1", "18.1", "", "", "89.2", "80.2", "", "58.6", "", "2", "", "", "102", "1", "2", "98.7", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.7", "99.1", "", "", "", "", "97.3"]} -{"pcdb_id": 16019, "brand_name": "Halstead", "model_name": "Iheat", "model_qualifier": "24c", "winter_efficiency_pct": 85.4, "summer_efficiency_pct": 76.8, "comparative_hot_water_efficiency_pct": 54.0, "output_kw_max": 24.35, "final_year_of_manufacture": null, "raw": ["016019", "000019", "0", "2009/Jan/20 16:27", "Halstead Boilers", "Halstead", "Iheat", "24c", "4726019", "2008", "current", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "24.35", "24.35", "", "", "85.4", "76.8", "", "54.0", "", "2", "", "", "104", "1", "2", "150", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "90.2", "", "", "", "", "89.7"]} -{"pcdb_id": 16020, "brand_name": "Grandee", "model_name": "GSCF 10-15", "model_qualifier": "", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 78.9, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 12.0, "final_year_of_manufacture": null, "raw": ["016020", "000259", "0", "2012/Mar/27 10:12", "Grandee Boilers", "Grandee", "GSCF 10-15", "", "", "2008", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "10", "12", "", "", "86.7", "78.9", "", "57.7", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "89.3", "92.4", "", "", "", "", "91.8"]} -{"pcdb_id": 16021, "brand_name": "Grandee", "model_name": "GCF 10-15", "model_qualifier": "", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 78.9, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 12.0, "final_year_of_manufacture": null, "raw": ["016021", "000259", "0", "2012/Mar/27 10:12", "Grandee Boilers", "Grandee", "GCF 10-15", "", "", "2008", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "10", "12", "", "", "86.7", "78.9", "", "57.7", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "89.3", "92.4", "", "", "", "", "91.8"]} -{"pcdb_id": 16022, "brand_name": "Grandee", "model_name": "GCCF 15/23", "model_qualifier": "", "winter_efficiency_pct": 87.4, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 56.2, "output_kw_max": 20.0, "final_year_of_manufacture": null, "raw": ["016022", "000259", "0", "2009/Mar/31 13:53", "Grandee Boilers", "Grandee", "GCCF 15/23", "", "", "2008", "current", "4", "1", "1", "2", "0", "", "", "2", "3", "1", "15", "20", "", "", "87.4", "80.0", "", "56.2", "", "2", "", "", "202", "1", "1", "", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.4", "93.3", "", "", "", "", "92.8"]} -{"pcdb_id": 16024, "brand_name": "Grandee", "model_name": "GSCW 10-15", "model_qualifier": "", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 78.9, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 12.0, "final_year_of_manufacture": null, "raw": ["016024", "000259", "0", "2012/Mar/27 10:12", "Grandee Boilers", "Grandee", "GSCW 10-15", "", "", "2008", "current", "4", "2", "1", "1", "0", "", "", "2", "3", "1", "10", "12", "", "", "86.7", "78.9", "", "57.7", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "89.3", "92.4", "", "", "", "", "91.8"]} -{"pcdb_id": 16025, "brand_name": "Grandee", "model_name": "GSCW 10-15 Ext", "model_qualifier": "", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 78.9, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 15.0, "final_year_of_manufacture": null, "raw": ["016025", "000259", "0", "2012/Mar/27 10:12", "Grandee Boilers", "Grandee", "GSCW 10-15 Ext", "", "", "2008", "current", "4", "2", "2", "1", "0", "", "", "2", "3", "1", "10", "15", "", "", "86.7", "78.9", "", "57.7", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "89.3", "92.4", "", "", "", "", "91.8"]} -{"pcdb_id": 16026, "brand_name": "Grandee", "model_name": "GCW 10-15 Ext", "model_qualifier": "", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 78.9, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 15.0, "final_year_of_manufacture": null, "raw": ["016026", "000259", "0", "2012/Mar/27 10:12", "Grandee Boilers", "Grandee", "GCW 10-15 Ext", "", "", "2008", "current", "4", "2", "2", "1", "0", "", "", "2", "3", "1", "10", "15", "", "", "86.7", "78.9", "", "57.7", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "89.3", "92.4", "", "", "", "", "91.8"]} -{"pcdb_id": 16027, "brand_name": "Grandee", "model_name": "GCW 10-15", "model_qualifier": "", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 78.9, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 12.0, "final_year_of_manufacture": null, "raw": ["016027", "000259", "0", "2012/Mar/27 10:12", "Grandee Boilers", "Grandee", "GCW 10-15", "", "", "2008", "current", "4", "2", "1", "1", "0", "", "", "2", "3", "1", "10", "12", "", "", "86.7", "78.9", "", "57.7", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "89.3", "92.4", "", "", "", "", "91.8"]} -{"pcdb_id": 16030, "brand_name": "Grandee", "model_name": "GSCF 15/23", "model_qualifier": "", "winter_efficiency_pct": 87.4, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 20.0, "final_year_of_manufacture": null, "raw": ["016030", "000259", "0", "2012/Mar/27 10:12", "Grandee Boilers", "Grandee", "GSCF 15/23", "", "", "2008", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "15", "20", "", "", "87.4", "79.6", "", "58.1", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.4", "93.3", "", "", "", "", "92.8"]} -{"pcdb_id": 16032, "brand_name": "Grandee", "model_name": "GCF 15/23", "model_qualifier": "", "winter_efficiency_pct": 87.4, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 20.0, "final_year_of_manufacture": null, "raw": ["016032", "000259", "0", "2012/Mar/27 10:12", "Grandee Boilers", "Grandee", "GCF 15/23", "", "", "2008", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "15", "20", "", "", "87.4", "79.6", "", "58.1", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.4", "93.3", "", "", "", "", "92.8"]} -{"pcdb_id": 16034, "brand_name": "Grandee", "model_name": "GCCF 23/30", "model_qualifier": "", "winter_efficiency_pct": 87.0, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 56.0, "output_kw_max": 26.0, "final_year_of_manufacture": null, "raw": ["016034", "000259", "0", "2009/Mar/31 14:00", "Grandee Boilers", "Grandee", "GCCF 23/30", "", "", "2008", "current", "4", "1", "1", "2", "0", "", "", "2", "3", "1", "23", "26", "", "", "87.0", "79.6", "", "56.0", "", "2", "", "", "202", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.1", "92.6", "", "", "", "", "92.1"]} -{"pcdb_id": 16036, "brand_name": "Grandee", "model_name": "GSCF 23/30", "model_qualifier": "", "winter_efficiency_pct": 87.0, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 26.0, "final_year_of_manufacture": null, "raw": ["016036", "000259", "0", "2012/Mar/27 10:12", "Grandee Boilers", "Grandee", "GSCF 23/30", "", "", "2008", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "23", "26", "", "", "87.0", "79.2", "", "57.9", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.1", "92.6", "", "", "", "", "92.1"]} -{"pcdb_id": 16038, "brand_name": "Grandee", "model_name": "GCCW 23/28 Ext", "model_qualifier": "", "winter_efficiency_pct": 87.0, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 56.0, "output_kw_max": 26.0, "final_year_of_manufacture": null, "raw": ["016038", "000259", "0", "2009/Aug/24 17:03", "Grandee Boilers", "Grandee", "GCCW 23/28 Ext", "", "", "2008", "current", "4", "2", "2", "2", "0", "", "", "2", "3", "1", "23", "26", "", "", "87.0", "79.6", "", "56.0", "", "2", "", "", "202", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.1", "92.6", "", "", "", "", "92.1"]} -{"pcdb_id": 16039, "brand_name": "Grandee", "model_name": "GCF 23/30", "model_qualifier": "", "winter_efficiency_pct": 87.0, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 26.0, "final_year_of_manufacture": null, "raw": ["016039", "000259", "0", "2012/Mar/27 10:12", "Grandee Boilers", "Grandee", "GCF 23/30", "", "", "2008", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "23", "26", "", "", "87.0", "79.2", "", "57.9", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.1", "92.6", "", "", "", "", "92.1"]} -{"pcdb_id": 16040, "brand_name": "Grandee", "model_name": "GCCW 23/28", "model_qualifier": "", "winter_efficiency_pct": 87.0, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 56.0, "output_kw_max": 26.0, "final_year_of_manufacture": null, "raw": ["016040", "000259", "0", "2009/Mar/31 13:59", "Grandee Boilers", "Grandee", "GCCW 23/28", "", "", "2008", "current", "4", "2", "1", "2", "0", "", "", "2", "3", "1", "23", "26", "", "", "87.0", "79.6", "", "56.0", "", "2", "", "", "202", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.1", "92.6", "", "", "", "", "92.1"]} -{"pcdb_id": 16041, "brand_name": "Grandee", "model_name": "GSCW 23/28 Ext", "model_qualifier": "", "winter_efficiency_pct": 87.0, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 26.0, "final_year_of_manufacture": null, "raw": ["016041", "000259", "0", "2012/Mar/27 10:12", "Grandee Boilers", "Grandee", "GSCW 23/28 Ext", "", "", "2008", "current", "4", "2", "2", "1", "0", "", "", "2", "3", "1", "23", "26", "", "", "87.0", "79.2", "", "57.9", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.1", "92.6", "", "", "", "", "92.1"]} -{"pcdb_id": 16042, "brand_name": "Grandee", "model_name": "GCW 23/28 Ext", "model_qualifier": "", "winter_efficiency_pct": 87.0, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 26.0, "final_year_of_manufacture": null, "raw": ["016042", "000259", "0", "2012/Mar/27 10:12", "Grandee Boilers", "Grandee", "GCW 23/28 Ext", "", "", "2008", "current", "4", "2", "2", "1", "0", "", "", "2", "3", "1", "23", "26", "", "", "87.0", "79.2", "", "57.9", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.1", "92.6", "", "", "", "", "92.1"]} -{"pcdb_id": 16043, "brand_name": "Grandee", "model_name": "GSCW 23/28", "model_qualifier": "", "winter_efficiency_pct": 87.0, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 26.0, "final_year_of_manufacture": null, "raw": ["016043", "000259", "0", "2012/Mar/27 10:12", "Grandee Boilers", "Grandee", "GSCW 23/28", "", "", "2008", "current", "4", "2", "1", "1", "0", "", "", "2", "3", "1", "23", "26", "", "", "87.0", "79.2", "", "57.9", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.1", "92.6", "", "", "", "", "92.1"]} -{"pcdb_id": 16044, "brand_name": "Grandee", "model_name": "GCW 23/28", "model_qualifier": "", "winter_efficiency_pct": 87.0, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 26.0, "final_year_of_manufacture": null, "raw": ["016044", "000259", "0", "2012/Mar/27 10:12", "Grandee Boilers", "Grandee", "GCW 23/28", "", "", "2008", "current", "4", "2", "1", "1", "0", "", "", "2", "3", "1", "23", "26", "", "", "87.0", "79.2", "", "57.9", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.1", "92.6", "", "", "", "", "92.1"]} -{"pcdb_id": 16045, "brand_name": "Grandee", "model_name": "GCW 15/22", "model_qualifier": "", "winter_efficiency_pct": 87.4, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 20.0, "final_year_of_manufacture": null, "raw": ["016045", "000259", "0", "2012/Mar/27 10:12", "Grandee Boilers", "Grandee", "GCW 15/22", "", "", "2008", "current", "4", "2", "1", "1", "0", "", "", "2", "3", "1", "15", "20", "", "", "87.4", "79.6", "", "58.1", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.4", "93.3", "", "", "", "", "92.8"]} -{"pcdb_id": 16046, "brand_name": "Grandee", "model_name": "GCW 15/22 Ext", "model_qualifier": "", "winter_efficiency_pct": 87.4, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 20.0, "final_year_of_manufacture": null, "raw": ["016046", "000259", "0", "2012/Mar/27 10:12", "Grandee Boilers", "Grandee", "GCW 15/22 Ext", "", "", "2008", "current", "4", "2", "2", "1", "0", "", "", "2", "3", "1", "15", "20", "", "", "87.4", "79.6", "", "58.1", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.4", "93.3", "", "", "", "", "92.8"]} -{"pcdb_id": 16047, "brand_name": "Grandee", "model_name": "GSCW 15/22 Ext", "model_qualifier": "", "winter_efficiency_pct": 87.4, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 20.0, "final_year_of_manufacture": null, "raw": ["016047", "000259", "0", "2012/Mar/27 10:12", "Grandee Boilers", "Grandee", "GSCW 15/22 Ext", "", "", "2008", "current", "4", "2", "2", "1", "0", "", "", "2", "3", "1", "15", "20", "", "", "87.4", "79.6", "", "58.1", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.4", "93.3", "", "", "", "", "92.8"]} -{"pcdb_id": 16048, "brand_name": "Grandee", "model_name": "GSCW 15/22", "model_qualifier": "", "winter_efficiency_pct": 87.4, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 20.0, "final_year_of_manufacture": null, "raw": ["016048", "000259", "0", "2012/Mar/27 10:12", "Grandee Boilers", "Grandee", "GSCW 15/22", "", "", "2008", "current", "4", "2", "1", "1", "0", "", "", "2", "3", "1", "15", "20", "", "", "87.4", "79.6", "", "58.1", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.4", "93.3", "", "", "", "", "92.8"]} -{"pcdb_id": 16049, "brand_name": "Grandee", "model_name": "GCCW 15/22", "model_qualifier": "", "winter_efficiency_pct": 87.4, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 56.2, "output_kw_max": 20.0, "final_year_of_manufacture": null, "raw": ["016049", "000259", "0", "2009/Mar/31 13:41", "Grandee Boilers", "Grandee", "GCCW 15/22", "", "", "2008", "current", "4", "2", "1", "2", "0", "", "", "2", "3", "1", "15", "20", "", "", "87.4", "80.0", "", "56.2", "", "2", "", "", "202", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.4", "93.3", "", "", "", "", "92.8"]} -{"pcdb_id": 16050, "brand_name": "Grandee", "model_name": "GCCW 15/22 Ext", "model_qualifier": "", "winter_efficiency_pct": 87.4, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 56.2, "output_kw_max": 20.0, "final_year_of_manufacture": null, "raw": ["016050", "000259", "0", "2009/Aug/24 17:02", "Grandee Boilers", "Grandee", "GCCW 15/22 Ext", "", "", "2008", "current", "4", "2", "2", "2", "0", "", "", "2", "3", "1", "15", "20", "", "", "87.4", "80.0", "", "56.2", "", "2", "", "", "202", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.4", "93.3", "", "", "", "", "92.8"]} -{"pcdb_id": 16052, "brand_name": "Halstead", "model_name": "Ace HE35", "model_qualifier": "", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 56.3, "output_kw_max": 24.0, "final_year_of_manufacture": null, "raw": ["016052", "000019", "0", "2009/May/21 12:53", "Halstead Boilers", "Halstead", "Ace HE35", "", "GC No. 47-260-13", "2007", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "88.7", "80.1", "", "56.3", "", "2", "", "", "104", "1", "2", "145", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.9", "98.2", "", "", "", "", "96.4"]} -{"pcdb_id": 16053, "brand_name": "Halstead", "model_name": "Eden CBX 38", "model_qualifier": "", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.4, "comparative_hot_water_efficiency_pct": 56.5, "output_kw_max": 30.0, "final_year_of_manufacture": null, "raw": ["016053", "000019", "0", "2009/May/21 12:54", "Halstead Boilers", "Halstead", "Eden CBX 38", "", "", "2008", "current", "2", "2", "1", "2", "0", "", "", "2", "3", "2", "30", "30", "", "", "89.0", "80.4", "", "56.5", "", "2", "1", "", "104", "1", "2", "148", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.3", "98.7", "", "", "", "", "97.1"]} -{"pcdb_id": 16054, "brand_name": "Halstead", "model_name": "Eden CBX 38", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 55.8, "output_kw_max": 30.0, "final_year_of_manufacture": null, "raw": ["016054", "000019", "0", "2009/May/21 12:54", "Halstead Boilers", "Halstead", "Eden CBX 38", "", "GC 47-260-14", "2008", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "30", "30", "", "", "88.0", "79.4", "", "55.8", "", "2", "", "", "104", "1", "2", "148", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "96.6", "", "", "", "", "95.0"]} -{"pcdb_id": 16064, "brand_name": "Halstead", "model_name": "Pulsejet 20", "model_qualifier": "", "winter_efficiency_pct": 87.1, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 20.0, "final_year_of_manufacture": null, "raw": ["016064", "000019", "0", "2012/Mar/27 10:12", "Halstead Boilers", "Halstead", "Pulsejet 20", "", "955490", "2009", "current", "1", "1", "1", "1", "0", "", "", "2", "3", "2", "20", "20", "", "", "87.1", "79.5", "", "58.1", "", "2", "", "", "101", "1", "1", "25", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "88.9", "97.7", "", "", "", "", "96.0"]} -{"pcdb_id": 16065, "brand_name": "Halstead", "model_name": "Pulsejet 20", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 58.8, "output_kw_max": 20.0, "final_year_of_manufacture": null, "raw": ["016065", "000019", "0", "2012/Mar/27 10:12", "Halstead Boilers", "Halstead", "Pulsejet 20", "", "", "2009", "current", "2", "1", "1", "1", "0", "", "", "2", "3", "2", "20", "20", "", "", "88.1", "80.5", "", "58.8", "", "2", "1", "", "101", "1", "1", "25", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.7", "99.8", "", "", "", "", "98.1"]} -{"pcdb_id": 16066, "brand_name": "Halstead", "model_name": "Pulsejet 32", "model_qualifier": "", "winter_efficiency_pct": 87.0, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 33.2, "final_year_of_manufacture": null, "raw": ["016066", "000019", "0", "2012/Mar/27 10:12", "Halstead Boilers", "Halstead", "Pulsejet 32", "", "955491", "2009", "current", "1", "1", "1", "1", "0", "", "", "2", "3", "2", "33.2", "33.2", "", "", "87.0", "79.4", "", "58.0", "", "2", "", "", "101", "1", "1", "25", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "88.7", "97.4", "", "", "", "", "95.8"]} -{"pcdb_id": 16067, "brand_name": "Halstead", "model_name": "Pulsejet 32", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 80.4, "comparative_hot_water_efficiency_pct": 58.7, "output_kw_max": 33.2, "final_year_of_manufacture": null, "raw": ["016067", "000019", "0", "2012/Mar/27 10:12", "Halstead Boilers", "Halstead", "Pulsejet 32", "", "", "2009", "current", "2", "1", "1", "1", "0", "", "", "2", "3", "2", "33.2", "33.2", "", "", "88.0", "80.4", "", "58.7", "", "2", "1", "", "101", "1", "1", "25", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.7", "99.6", "", "", "", "", "97.9"]} -{"pcdb_id": 16068, "brand_name": "Halstead", "model_name": "Pulsejet 40", "model_qualifier": "", "winter_efficiency_pct": 87.0, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 40.0, "final_year_of_manufacture": null, "raw": ["016068", "000019", "0", "2012/Mar/27 10:12", "Halstead Boilers", "Halstead", "Pulsejet 40", "", "955492", "2009", "current", "1", "1", "1", "1", "0", "", "", "2", "3", "2", "40", "40", "", "", "87.0", "79.4", "", "58.0", "", "2", "", "", "101", "1", "1", "25", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "88.7", "97.5", "", "", "", "", "95.8"]} -{"pcdb_id": 16069, "brand_name": "Halstead", "model_name": "Pulsejet 40", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 80.4, "comparative_hot_water_efficiency_pct": 58.7, "output_kw_max": 40.0, "final_year_of_manufacture": null, "raw": ["016069", "000019", "0", "2012/Mar/27 10:12", "Halstead Boilers", "Halstead", "Pulsejet 40", "", "", "2009", "current", "2", "1", "1", "1", "0", "", "", "2", "3", "2", "40", "40", "", "", "88.0", "80.4", "", "58.7", "", "2", "1", "", "101", "1", "1", "25", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.7", "99.7", "", "", "", "", "98.0"]} -{"pcdb_id": 16070, "brand_name": "Fondital", "model_name": "Tahiti Dual HC 32 Line", "model_qualifier": "", "winter_efficiency_pct": 86.1, "summer_efficiency_pct": 77.5, "comparative_hot_water_efficiency_pct": 54.5, "output_kw_max": 30.3, "final_year_of_manufacture": null, "raw": ["016070", "000250", "0", "2009/Apr/24 09:31", "Fondital", "Fondital", "Tahiti Dual HC 32 Line", "", "", "2009", "current", "2", "2", "1", "2", "0", "", "", "2", "3", "2", "30.3", "30.3", "", "", "86.1", "77.5", "", "54.5", "", "2", "1", "", "104", "1", "2", "177", "10", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.5", "92.1", "", "", "", "", "91.4"]} -{"pcdb_id": 16071, "brand_name": "Fondital", "model_name": "Tahiti Dual HR 32 Line", "model_qualifier": "", "winter_efficiency_pct": 86.1, "summer_efficiency_pct": 77.1, "comparative_hot_water_efficiency_pct": 56.3, "output_kw_max": 30.3, "final_year_of_manufacture": null, "raw": ["016071", "000250", "0", "2012/Mar/27 10:12", "Fondital", "Fondital", "Tahiti Dual HR 32 Line", "", "", "2009", "current", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "30.3", "30.3", "", "", "86.1", "77.1", "", "56.3", "", "2", "1", "", "102", "1", "2", "177", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.5", "92.1", "", "", "", "", "91.4"]} -{"pcdb_id": 16072, "brand_name": "Fondital", "model_name": "Tahiti Dual HRB 32 Line", "model_qualifier": "", "winter_efficiency_pct": 86.1, "summer_efficiency_pct": 77.1, "comparative_hot_water_efficiency_pct": 56.3, "output_kw_max": 30.3, "final_year_of_manufacture": null, "raw": ["016072", "000250", "0", "2012/Mar/27 10:12", "Fondital", "Fondital", "Tahiti Dual HRB 32 Line", "", "", "2009", "current", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "30.3", "30.3", "", "", "86.1", "77.1", "", "56.3", "", "2", "1", "", "102", "1", "2", "177", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.5", "92.1", "", "", "", "", "91.4"]} -{"pcdb_id": 16073, "brand_name": "Fondital", "model_name": "Tahiti Dual HC 32 Line", "model_qualifier": "", "winter_efficiency_pct": 85.1, "summer_efficiency_pct": 76.5, "comparative_hot_water_efficiency_pct": 53.8, "output_kw_max": 30.3, "final_year_of_manufacture": null, "raw": ["016073", "000250", "0", "2009/Apr/24 09:32", "Fondital", "Fondital", "Tahiti Dual HC 32 Line", "", "", "2009", "current", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "30.3", "30.3", "", "", "85.1", "76.5", "", "53.8", "", "2", "", "", "104", "1", "2", "177", "10", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "86.6", "90.1", "", "", "", "", "89.4"]} -{"pcdb_id": 16074, "brand_name": "Fondital", "model_name": "Tahiti Dual HR 32 Line", "model_qualifier": "", "winter_efficiency_pct": 85.1, "summer_efficiency_pct": 76.1, "comparative_hot_water_efficiency_pct": 55.6, "output_kw_max": 30.3, "final_year_of_manufacture": null, "raw": ["016074", "000250", "0", "2012/Mar/27 10:12", "Fondital", "Fondital", "Tahiti Dual HR 32 Line", "", "", "2009", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "30.3", "30.3", "", "", "85.1", "76.1", "", "55.6", "", "2", "", "", "102", "1", "2", "177", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "86.6", "90.1", "", "", "", "", "89.4"]} -{"pcdb_id": 16075, "brand_name": "Fondital", "model_name": "Tahiti Dual HRB 32 Line", "model_qualifier": "", "winter_efficiency_pct": 85.1, "summer_efficiency_pct": 76.1, "comparative_hot_water_efficiency_pct": 55.6, "output_kw_max": 30.3, "final_year_of_manufacture": null, "raw": ["016075", "000250", "0", "2012/Mar/27 10:12", "Fondital", "Fondital", "Tahiti Dual HRB 32 Line", "", "", "2009", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "30.3", "30.3", "", "", "85.1", "76.1", "", "55.6", "", "2", "", "", "102", "1", "2", "177", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "86.6", "90.1", "", "", "", "", "89.4"]} -{"pcdb_id": 16080, "brand_name": "Ferroli", "model_name": "Optimax HE Plus", "model_qualifier": "18 S", "winter_efficiency_pct": 89.7, "summer_efficiency_pct": 80.7, "comparative_hot_water_efficiency_pct": 58.9, "output_kw_max": 17.7, "final_year_of_manufacture": 2017, "raw": ["016080", "000097", "0", "2017/Aug/21 13:41", "Ferroli", "Ferroli", "Optimax HE Plus", "18 S", "", "2009", "2017", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "17.7", "17.7", "", "", "89.7", "80.7", "", "58.9", "", "2", "1", "", "102", "1", "2", "115", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.5", "100.5", "", "", "", "", "98.6"]} -{"pcdb_id": 16081, "brand_name": "Ferroli", "model_name": "Optimax HE Plus", "model_qualifier": "18 OV", "winter_efficiency_pct": 89.7, "summer_efficiency_pct": 80.7, "comparative_hot_water_efficiency_pct": 58.9, "output_kw_max": 17.7, "final_year_of_manufacture": 2017, "raw": ["016081", "000097", "0", "2017/Aug/21 13:44", "Ferroli", "Ferroli", "Optimax HE Plus", "18 OV", "", "2009", "2017", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "17.7", "17.7", "", "", "89.7", "80.7", "", "58.9", "", "2", "1", "", "102", "1", "2", "50", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.5", "100.5", "", "", "", "", "98.6"]} -{"pcdb_id": 16082, "brand_name": "Ferroli", "model_name": "Optimax HE Plus", "model_qualifier": "25 OV", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 80.4, "comparative_hot_water_efficiency_pct": 58.7, "output_kw_max": 24.6, "final_year_of_manufacture": 2017, "raw": ["016082", "000097", "0", "2017/Aug/21 13:44", "Ferroli", "Ferroli", "Optimax HE Plus", "25 OV", "", "2009", "2017", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "24.6", "24.6", "", "", "89.4", "80.4", "", "58.7", "", "2", "1", "", "102", "1", "2", "50", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.5", "99.7", "", "", "", "", "98.0"]} -{"pcdb_id": 16083, "brand_name": "Ferroli", "model_name": "Optimax HE Plus", "model_qualifier": "25 S", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 80.4, "comparative_hot_water_efficiency_pct": 58.7, "output_kw_max": 24.6, "final_year_of_manufacture": 2017, "raw": ["016083", "000097", "0", "2017/Aug/21 13:45", "Ferroli", "Ferroli", "Optimax HE Plus", "25 S", "", "2009", "2017", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "24.6", "24.6", "", "", "89.4", "80.4", "", "58.7", "", "2", "1", "", "102", "1", "2", "115", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.5", "99.7", "", "", "", "", "98.0"]} -{"pcdb_id": 16084, "brand_name": "Ferroli", "model_name": "Optimax HE Plus", "model_qualifier": "31 C", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 56.8, "output_kw_max": 24.6, "final_year_of_manufacture": 2017, "raw": ["016084", "000097", "0", "2017/Aug/21 13:45", "Ferroli", "Ferroli", "Optimax HE Plus", "31 C", "", "2009", "2017", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24.6", "24.6", "", "", "89.4", "80.8", "", "56.8", "", "2", "1", "", "104", "1", "2", "130", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "0", "", "0005", "", "", "", "", "", "", "", "", "90.5", "99.7", "", "", "", "", "98.0"]} -{"pcdb_id": 16085, "brand_name": "Ferroli", "model_name": "Optimax HE Plus", "model_qualifier": "35 S", "winter_efficiency_pct": 89.7, "summer_efficiency_pct": 80.7, "comparative_hot_water_efficiency_pct": 59.0, "output_kw_max": 30.2, "final_year_of_manufacture": 2017, "raw": ["016085", "000097", "0", "2017/Aug/21 13:46", "Ferroli", "Ferroli", "Optimax HE Plus", "35 S", "", "2009", "2017", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "30.2", "30.2", "", "", "89.7", "80.7", "", "59.0", "", "2", "1", "", "102", "1", "2", "125", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.7", "100.5", "", "", "", "", "98.6"]} -{"pcdb_id": 16086, "brand_name": "Ferroli", "model_name": "Optimax HE Plus", "model_qualifier": "38 C", "winter_efficiency_pct": 89.7, "summer_efficiency_pct": 81.1, "comparative_hot_water_efficiency_pct": 57.1, "output_kw_max": 30.2, "final_year_of_manufacture": 2017, "raw": ["016086", "000097", "0", "2017/Aug/21 13:39", "Ferroli", "Ferroli", "Optimax HE Plus", "38 C", "", "2009", "2017", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "30.2", "30.2", "", "", "89.7", "81.1", "", "57.1", "", "2", "1", "", "104", "1", "2", "140", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "0", "", "0005", "", "", "", "", "", "", "", "", "90.7", "100.5", "", "", "", "", "98.6"]} -{"pcdb_id": 16087, "brand_name": "Ferroli", "model_name": "Optimax HE Plus", "model_qualifier": "18 S", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 17.7, "final_year_of_manufacture": 2017, "raw": ["016087", "000097", "0", "2017/Aug/07 16:54", "Ferroli", "Ferroli", "Optimax HE Plus", "18 S", "41-267-31", "2009", "2017", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "17.7", "17.7", "", "", "88.7", "79.7", "", "58.2", "", "2", "", "", "102", "1", "2", "115", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.6", "98.3", "", "", "", "", "96.5"]} -{"pcdb_id": 16089, "brand_name": "Ferroli", "model_name": "Optimax HE Plus", "model_qualifier": "18 OV", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 17.7, "final_year_of_manufacture": 2017, "raw": ["016089", "000097", "0", "2017/Aug/07 17:01", "Ferroli", "Ferroli", "Optimax HE Plus", "18 OV", "41-267-29", "2009", "2017", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "17.7", "17.7", "", "", "88.7", "79.7", "", "58.2", "", "2", "", "", "102", "1", "2", "50", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.6", "98.3", "", "", "", "", "96.5"]} -{"pcdb_id": 16090, "brand_name": "Ferroli", "model_name": "Optimax HE Plus", "model_qualifier": "25 OV", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 24.6, "final_year_of_manufacture": 2017, "raw": ["016090", "000097", "0", "2017/Aug/07 16:53", "Ferroli", "Ferroli", "Optimax HE Plus", "25 OV", "41-267-30", "2009", "2017", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24.6", "24.6", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "50", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.6", "97.6", "", "", "", "", "95.9"]} -{"pcdb_id": 16092, "brand_name": "Ferroli", "model_name": "Optimax HE Plus", "model_qualifier": "25 S", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 24.6, "final_year_of_manufacture": 2017, "raw": ["016092", "000097", "0", "2017/Aug/07 16:59", "Ferroli", "Ferroli", "Optimax HE Plus", "25 S", "41-267-32", "2009", "2017", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24.6", "24.6", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "115", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.6", "97.6", "", "", "", "", "95.9"]} -{"pcdb_id": 16093, "brand_name": "Ferroli", "model_name": "Optimax HE Plus", "model_qualifier": "31 C", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 56.1, "output_kw_max": 24.6, "final_year_of_manufacture": 2017, "raw": ["016093", "000097", "0", "2017/Aug/07 17:06", "Ferroli", "Ferroli", "Optimax HE Plus", "31 C", "47-267-44", "2009", "2017", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.6", "24.6", "", "", "88.4", "79.8", "", "56.1", "", "2", "", "", "104", "1", "2", "130", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "0", "", "0005", "", "", "", "", "", "", "", "", "88.6", "97.6", "", "", "", "", "95.9"]} -{"pcdb_id": 16094, "brand_name": "Ferroli", "model_name": "Optimax HE Plus", "model_qualifier": "35 S", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 30.2, "final_year_of_manufacture": 2017, "raw": ["016094", "000097", "0", "2017/Aug/21 13:34", "Ferroli", "Ferroli", "Optimax HE Plus", "35 S", "41-267-33", "2009", "2017", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "30.2", "30.2", "", "", "88.7", "79.7", "", "58.2", "", "2", "", "", "102", "1", "2", "125", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.7", "98.3", "", "", "", "", "96.5"]} -{"pcdb_id": 16095, "brand_name": "Ferroli", "model_name": "Optimax HE Plus", "model_qualifier": "38 C", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 56.3, "output_kw_max": 30.2, "final_year_of_manufacture": 2017, "raw": ["016095", "000097", "0", "2017/Aug/21 13:34", "Ferroli", "Ferroli", "Optimax HE Plus", "38 C", "47-267-45", "2009", "2017", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "30.2", "30.2", "", "", "88.7", "80.1", "", "56.3", "", "2", "", "", "104", "1", "2", "140", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "0", "", "0005", "", "", "", "", "", "", "", "", "88.7", "98.3", "", "", "", "", "96.5"]} -{"pcdb_id": 16096, "brand_name": "Vokera", "model_name": "Mynute", "model_qualifier": "24M", "winter_efficiency_pct": 81.1, "summer_efficiency_pct": 70.4, "comparative_hot_water_efficiency_pct": 51.4, "output_kw_max": 24.0, "final_year_of_manufacture": null, "raw": ["016096", "000011", "0", "2012/Mar/27 10:12", "Vokera", "Vokera", "Mynute", "24M", "4109441", "2005", "current", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "24", "24", "", "", "81.1", "70.4", "", "51.4", "", "2", "", "", "102", "1", "2", "150", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.6", "81.6", "", "", "", "", "81.8"]} -{"pcdb_id": 16097, "brand_name": "Firebird", "model_name": "Silverpac", "model_qualifier": "CR20", "winter_efficiency_pct": 87.7, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 20.0, "final_year_of_manufacture": 2010, "raw": ["016097", "000047", "0", "2012/Mar/27 10:12", "Firebird Boilers", "Firebird", "Silverpac", "CR20", "", "2008", "2010", "4", "1", "2", "1", "0", "", "", "2", "1", "1", "15", "20", "", "", "87.7", "79.9", "", "58.3", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.6", "93.6", "", "", "", "", "93.2"]} -{"pcdb_id": 16098, "brand_name": "Firebird", "model_name": "Silverpac", "model_qualifier": "CR26", "winter_efficiency_pct": 87.4, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 26.0, "final_year_of_manufacture": 2010, "raw": ["016098", "000047", "0", "2012/Mar/27 10:12", "Firebird Boilers", "Firebird", "Silverpac", "CR26", "", "2008", "2010", "4", "1", "2", "1", "0", "", "", "2", "1", "1", "15", "26", "", "", "87.4", "79.6", "", "58.1", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.8", "92.8", "", "", "", "", "92.6"]} -{"pcdb_id": 16099, "brand_name": "Firebird", "model_name": "Silverpac", "model_qualifier": "CR35", "winter_efficiency_pct": 86.2, "summer_efficiency_pct": 78.4, "comparative_hot_water_efficiency_pct": 57.3, "output_kw_max": 35.0, "final_year_of_manufacture": 2010, "raw": ["016099", "000047", "0", "2012/Mar/27 10:12", "Firebird Boilers", "Firebird", "Silverpac", "CR35", "", "2008", "2010", "4", "1", "2", "1", "0", "", "", "2", "1", "1", "26", "35", "", "", "86.2", "78.4", "", "57.3", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "89.3", "91.1", "", "", "", "", "90.7"]} -{"pcdb_id": 16100, "brand_name": "Firebird", "model_name": "Silver Utility", "model_qualifier": "CR20", "winter_efficiency_pct": 87.7, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 20.0, "final_year_of_manufacture": 2010, "raw": ["016100", "000047", "0", "2012/Mar/27 10:12", "Firebird Boilers", "Firebird", "Silver Utility", "CR20", "", "2008", "2010", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "15", "20", "", "", "87.7", "79.9", "", "58.3", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.6", "93.6", "", "", "", "", "93.2"]} -{"pcdb_id": 16101, "brand_name": "Firebird", "model_name": "Silver Utility", "model_qualifier": "CR26", "winter_efficiency_pct": 87.4, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 26.0, "final_year_of_manufacture": 2010, "raw": ["016101", "000047", "0", "2012/Mar/27 10:12", "Firebird Boilers", "Firebird", "Silver Utility", "CR26", "", "2008", "2010", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "15", "26", "", "", "87.4", "79.6", "", "58.1", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.8", "92.8", "", "", "", "", "92.6"]} -{"pcdb_id": 16102, "brand_name": "Firebird", "model_name": "Silver Utility", "model_qualifier": "CR35", "winter_efficiency_pct": 86.2, "summer_efficiency_pct": 78.4, "comparative_hot_water_efficiency_pct": 57.3, "output_kw_max": 35.0, "final_year_of_manufacture": 2010, "raw": ["016102", "000047", "0", "2012/Mar/27 10:12", "Firebird Boilers", "Firebird", "Silver Utility", "CR35", "", "2008", "2010", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "26", "35", "", "", "86.2", "78.4", "", "57.3", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "89.3", "91.1", "", "", "", "", "90.7"]} -{"pcdb_id": 16103, "brand_name": "Firebird", "model_name": "Silver Boilerhouse", "model_qualifier": "CR20", "winter_efficiency_pct": 87.7, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 20.0, "final_year_of_manufacture": 2010, "raw": ["016103", "000047", "0", "2012/Mar/27 10:12", "Firebird Boilers", "Firebird", "Silver Boilerhouse", "CR20", "", "2008", "2010", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "15", "20", "", "", "87.7", "79.9", "", "58.3", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.6", "93.6", "", "", "", "", "93.2"]} -{"pcdb_id": 16104, "brand_name": "Firebird", "model_name": "Silver Boilerhouse", "model_qualifier": "CR26", "winter_efficiency_pct": 87.4, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 26.0, "final_year_of_manufacture": 2010, "raw": ["016104", "000047", "0", "2012/Mar/27 10:12", "Firebird Boilers", "Firebird", "Silver Boilerhouse", "CR26", "", "2008", "2010", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "15", "26", "", "", "87.4", "79.6", "", "58.1", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.8", "92.8", "", "", "", "", "92.6"]} -{"pcdb_id": 16105, "brand_name": "Firebird", "model_name": "Silver Boilerhouse", "model_qualifier": "CR35", "winter_efficiency_pct": 86.2, "summer_efficiency_pct": 78.4, "comparative_hot_water_efficiency_pct": 57.3, "output_kw_max": 35.0, "final_year_of_manufacture": 2010, "raw": ["016105", "000047", "0", "2012/Mar/27 10:12", "Firebird Boilers", "Firebird", "Silver Boilerhouse", "CR35", "", "2008", "2010", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "26", "35", "", "", "86.2", "78.4", "", "57.3", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "89.3", "91.1", "", "", "", "", "90.7"]} -{"pcdb_id": 16106, "brand_name": "GEM", "model_name": "CKUT1 15/20", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 20.0, "final_year_of_manufacture": null, "raw": ["016106", "000260", "0", "2012/Mar/27 10:12", "GEM", "GEM", "CKUT1 15/20", "", "", "2007", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "15", "20", "", "", "88.0", "80.2", "", "58.6", "", "2", "", "", "201", "1", "1", "230", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.8", "94.8", "", "", "", "", "94.1"]} -{"pcdb_id": 16107, "brand_name": "GEM", "model_name": "CKUT2 20/26", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 26.0, "final_year_of_manufacture": null, "raw": ["016107", "000260", "0", "2012/Mar/27 10:12", "GEM Heating Products", "GEM", "CKUT2 20/26", "", "", "2007", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "20", "26", "", "", "88.0", "80.2", "", "58.6", "", "2", "", "", "201", "1", "1", "230", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.8", "94.8", "", "", "", "", "94.1"]} -{"pcdb_id": 16108, "brand_name": "GEM", "model_name": "CKUT3 26/35", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 58.7, "output_kw_max": 35.0, "final_year_of_manufacture": null, "raw": ["016108", "000260", "0", "2012/Mar/27 10:12", "GEM Heating Products", "GEM", "CKUT3 26/35", "", "", "2007", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "26", "35", "", "", "88.1", "80.3", "", "58.7", "", "2", "", "", "201", "1", "1", "230", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.7", "95.2", "", "", "", "", "94.3"]} -{"pcdb_id": 16109, "brand_name": "GEM", "model_name": "CKUT4 35/41", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 58.7, "output_kw_max": 40.0, "final_year_of_manufacture": null, "raw": ["016109", "000260", "0", "2012/Mar/27 10:12", "GEM Heating Products", "GEM", "CKUT4 35/41", "", "", "2007", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "35", "40", "", "", "88.1", "80.3", "", "58.7", "", "2", "", "", "201", "1", "1", "230", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.7", "95.2", "", "", "", "", "94.3"]} -{"pcdb_id": 16110, "brand_name": "GEM", "model_name": "CC1 15/20", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 81.9, "comparative_hot_water_efficiency_pct": 50.3, "output_kw_max": 20.5, "final_year_of_manufacture": null, "raw": ["016110", "000260", "0", "2024/Jan/31 10:17", "GEM Heating Products", "GEM", "CC1 15/20", "", "", "2007", "current", "4", "1", "1", "2", "0", "", "", "2", "3", "2", "15", "20.5", "", "", "88.0", "81.9", "", "50.3", "", "2", "", "", "203", "1", "1", "230", "", "2", "1", "0", "35", "0", "25", "3", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.8", "94.8", "", "", "", "", "94.1"]} -{"pcdb_id": 16111, "brand_name": "GEM", "model_name": "CC2 20/26", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 81.9, "comparative_hot_water_efficiency_pct": 50.3, "output_kw_max": 26.0, "final_year_of_manufacture": null, "raw": ["016111", "000260", "0", "2024/Jan/31 10:17", "GEM Heating Products", "GEM", "CC2 20/26", "", "", "2007", "current", "4", "1", "1", "2", "0", "", "", "2", "3", "2", "20", "26", "", "", "88.0", "81.9", "", "50.3", "", "2", "", "", "203", "1", "1", "230", "", "2", "1", "0", "35", "0", "25", "3", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.8", "94.8", "", "", "", "", "94.1"]} -{"pcdb_id": 16112, "brand_name": "GEM", "model_name": "CC3 26/35", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 82.0, "comparative_hot_water_efficiency_pct": 50.4, "output_kw_max": 35.0, "final_year_of_manufacture": null, "raw": ["016112", "000260", "0", "2024/Jan/31 10:17", "GEM Heating Products", "GEM", "CC3 26/35", "", "", "2007", "current", "4", "1", "1", "2", "0", "", "", "2", "3", "2", "26", "35", "", "", "88.1", "82.0", "", "50.4", "", "2", "", "", "203", "1", "1", "", "", "2", "1", "0", "35", "0", "25", "3", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.7", "95.2", "", "", "", "", "94.3"]} -{"pcdb_id": 16113, "brand_name": "GEM", "model_name": "CC4 35/41", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 82.0, "comparative_hot_water_efficiency_pct": 50.4, "output_kw_max": 40.0, "final_year_of_manufacture": null, "raw": ["016113", "000260", "0", "2024/Jan/31 10:17", "GEM Heating Products", "GEM", "CC4 35/41", "", "", "2007", "current", "4", "1", "2", "2", "0", "", "", "2", "3", "2", "35", "40", "", "", "88.1", "82.0", "", "50.4", "", "2", "", "", "203", "1", "1", "230", "", "2", "1", "0", "35", "0", "25", "3", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.7", "95.2", "", "", "", "", "94.3"]} -{"pcdb_id": 16114, "brand_name": "GEM", "model_name": "CS1 15/20", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 20.5, "final_year_of_manufacture": null, "raw": ["016114", "000260", "0", "2012/Mar/27 10:12", "GEM Heating Products", "GEM", "CS1 15/20", "", "", "2007", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "15", "20.5", "", "", "88.0", "80.2", "", "58.6", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.8", "94.8", "", "", "", "", "94.1"]} -{"pcdb_id": 16115, "brand_name": "GEM", "model_name": "CS2 20/26", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 26.4, "final_year_of_manufacture": null, "raw": ["016115", "000260", "0", "2012/Mar/27 10:12", "GEM Heating Products", "GEM", "CS2 20/26", "", "", "2007", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "20.5", "26.4", "", "", "88.0", "80.2", "", "58.6", "", "2", "", "", "201", "1", "1", "230", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.8", "94.8", "", "", "", "", "94.1"]} -{"pcdb_id": 16116, "brand_name": "GEM", "model_name": "CS3 26/35", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 58.7, "output_kw_max": 35.0, "final_year_of_manufacture": null, "raw": ["016116", "000260", "0", "2012/Mar/27 10:12", "GEM Heating Products", "GEM", "CS3 26/35", "", "", "2007", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "26", "35", "", "", "88.1", "80.3", "", "58.7", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.7", "95.2", "", "", "", "", "94.3"]} -{"pcdb_id": 16117, "brand_name": "GEM", "model_name": "CS4 35/41", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 58.7, "output_kw_max": 40.0, "final_year_of_manufacture": null, "raw": ["016117", "000260", "0", "2012/Mar/27 10:12", "GEM Heating Products", "GEM", "CS4 35/41", "", "", "2007", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "35", "40", "", "", "88.1", "80.3", "", "58.7", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.7", "95.2", "", "", "", "", "94.3"]} -{"pcdb_id": 16118, "brand_name": "GEM", "model_name": "COD1 15/20", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 20.0, "final_year_of_manufacture": null, "raw": ["016118", "000260", "0", "2012/Mar/27 10:12", "GEM Heating Products", "GEM", "COD1 15/20", "", "", "2007", "current", "4", "1", "2", "1", "0", "", "", "2", "3", "2", "15", "20", "", "", "88.0", "80.2", "", "58.6", "", "2", "", "", "201", "1", "1", "230", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.8", "94.8", "", "", "", "", "94.1"]} -{"pcdb_id": 16119, "brand_name": "GEM", "model_name": "COD C1 15/20", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 81.9, "comparative_hot_water_efficiency_pct": 50.3, "output_kw_max": 20.0, "final_year_of_manufacture": null, "raw": ["016119", "000260", "0", "2024/Jan/31 10:17", "GEM Heating Products", "GEM", "COD C1 15/20", "", "", "2007", "current", "4", "1", "2", "2", "0", "", "", "2", "3", "2", "15", "20", "", "", "88.0", "81.9", "", "50.3", "", "2", "", "", "203", "1", "1", "230", "", "2", "1", "0", "35", "0", "25", "3", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "0", "", "0003", "", "", "", "", "", "", "", "", "90.8", "94.8", "", "", "", "", "94.1"]} -{"pcdb_id": 16120, "brand_name": "GEM", "model_name": "COD1 SS 15/20", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 20.0, "final_year_of_manufacture": null, "raw": ["016120", "000260", "0", "2012/Mar/27 10:12", "GEM Heating Products", "GEM", "COD1 SS 15/20", "", "", "2007", "current", "4", "1", "2", "1", "0", "", "", "2", "3", "2", "15", "20", "", "", "88.0", "80.2", "", "58.6", "", "2", "", "", "201", "1", "1", "230", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.8", "94.8", "", "", "", "", "94.1"]} -{"pcdb_id": 16121, "brand_name": "GEM", "model_name": "COD2 20/26", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 26.0, "final_year_of_manufacture": null, "raw": ["016121", "000260", "0", "2012/Mar/27 10:12", "GEM Heating Products", "GEM", "COD2 20/26", "", "", "2007", "current", "4", "1", "2", "1", "0", "", "", "2", "3", "2", "20", "26", "", "", "88.0", "80.2", "", "58.6", "", "2", "", "", "201", "1", "1", "230", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.8", "94.8", "", "", "", "", "94.1"]} -{"pcdb_id": 16122, "brand_name": "GEM", "model_name": "COD C2 20/26", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 81.9, "comparative_hot_water_efficiency_pct": 50.3, "output_kw_max": 26.0, "final_year_of_manufacture": null, "raw": ["016122", "000260", "0", "2024/Jan/31 10:17", "GEM Heating Products", "GEM", "COD C2 20/26", "", "", "2007", "current", "4", "1", "2", "2", "0", "", "", "2", "3", "2", "20", "26", "", "", "88.0", "81.9", "", "50.3", "", "2", "", "", "203", "1", "1", "230", "", "2", "1", "0", "35", "0", "25", "3", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.8", "94.8", "", "", "", "", "94.1"]} -{"pcdb_id": 16123, "brand_name": "GEM", "model_name": "COD2 SS 20/26", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 26.4, "final_year_of_manufacture": null, "raw": ["016123", "000260", "0", "2012/Mar/27 10:12", "GEM Heating Products", "GEM", "COD2 SS 20/26", "", "", "2007", "current", "4", "1", "2", "1", "0", "", "", "2", "3", "2", "20.5", "26.4", "", "", "88.0", "80.2", "", "58.6", "", "2", "", "", "201", "1", "1", "230", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.8", "94.8", "", "", "", "", "94.1"]} -{"pcdb_id": 16124, "brand_name": "GEM", "model_name": "COD3 26/35", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 58.7, "output_kw_max": 35.0, "final_year_of_manufacture": null, "raw": ["016124", "000260", "0", "2012/Mar/27 10:12", "GEM Heating Products", "GEM", "COD3 26/35", "", "", "2007", "current", "4", "1", "2", "1", "0", "", "", "2", "3", "2", "26", "35", "", "", "88.1", "80.3", "", "58.7", "", "2", "", "", "201", "1", "1", "230", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.7", "95.2", "", "", "", "", "94.3"]} -{"pcdb_id": 16125, "brand_name": "GEM", "model_name": "COD C3 26/35", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 82.0, "comparative_hot_water_efficiency_pct": 50.4, "output_kw_max": 35.0, "final_year_of_manufacture": null, "raw": ["016125", "000260", "0", "2024/Jan/31 10:17", "GEM Heating Products", "GEM", "COD C3 26/35", "", "", "2007", "current", "4", "1", "2", "2", "0", "", "", "2", "3", "2", "26", "35", "", "", "88.1", "82.0", "", "50.4", "", "2", "", "", "203", "1", "1", "230", "", "2", "1", "0", "35", "0", "25", "3", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.7", "95.2", "", "", "", "", "94.3"]} -{"pcdb_id": 16126, "brand_name": "GEM", "model_name": "COD3 SS 26/35", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 58.7, "output_kw_max": 35.0, "final_year_of_manufacture": null, "raw": ["016126", "000260", "0", "2012/Mar/27 10:12", "GEM Heating Products", "GEM", "COD3 SS 26/35", "", "", "2007", "current", "4", "1", "2", "1", "0", "", "", "2", "3", "2", "26", "35", "", "", "88.1", "80.3", "", "58.7", "", "2", "", "", "201", "1", "1", "230", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.7", "95.2", "", "", "", "", "94.3"]} -{"pcdb_id": 16127, "brand_name": "GEM", "model_name": "COD4 35/41", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 58.7, "output_kw_max": 40.0, "final_year_of_manufacture": null, "raw": ["016127", "000260", "0", "2012/Mar/27 10:12", "GEM Heating Products", "GEM", "COD4 35/41", "", "", "2007", "current", "4", "1", "2", "1", "0", "", "", "2", "3", "2", "35", "40", "", "", "88.1", "80.3", "", "58.7", "", "2", "", "", "201", "1", "1", "230", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.7", "95.2", "", "", "", "", "94.3"]} -{"pcdb_id": 16128, "brand_name": "GEM", "model_name": "COD C4 35/41", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 82.0, "comparative_hot_water_efficiency_pct": 50.4, "output_kw_max": 40.0, "final_year_of_manufacture": null, "raw": ["016128", "000260", "0", "2024/Jan/31 10:17", "GEM Heating Products", "GEM", "COD C4 35/41", "", "", "2007", "current", "4", "1", "2", "2", "0", "", "", "2", "3", "2", "35", "40", "", "", "88.1", "82.0", "", "50.4", "", "2", "", "", "203", "1", "1", "230", "", "2", "1", "0", "35", "0", "25", "3", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.7", "95.2", "", "", "", "", "94.3"]} -{"pcdb_id": 16129, "brand_name": "GEM", "model_name": "COD4 SS 35/41", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 58.7, "output_kw_max": 40.0, "final_year_of_manufacture": null, "raw": ["016129", "000260", "0", "2012/Mar/27 10:12", "GEM Heating Products", "GEM", "COD4 SS 35/41", "", "", "2007", "current", "4", "1", "2", "1", "0", "", "", "2", "3", "1", "35", "40", "", "", "88.1", "80.3", "", "58.7", "", "2", "", "", "201", "1", "1", "230", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.7", "95.2", "", "", "", "", "94.3"]} -{"pcdb_id": 16130, "brand_name": "Warmflow", "model_name": "Boilerhouse", "model_qualifier": "B70HE", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 21.0, "final_year_of_manufacture": null, "raw": ["016130", "000063", "0", "2013/Mar/28 08:29", "Warmflow Engineering", "Warmflow", "Boilerhouse", "B70HE", "", "2009", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "15", "21", "", "", "87.9", "80.1", "", "58.5", "", "2", "", "", "201", "1", "1", "160", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "89.9", "95.0", "", "", "", "", "94.0"]} -{"pcdb_id": 16132, "brand_name": "Warmflow", "model_name": "Boilerhouse", "model_qualifier": "B90HE", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 26.0, "final_year_of_manufacture": null, "raw": ["016132", "000063", "0", "2013/Mar/28 08:29", "Warmflow Engineering", "Warmflow", "Boilerhouse", "B90HE", "", "2009", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "21", "26", "", "", "87.9", "80.1", "", "58.5", "", "2", "", "", "201", "1", "1", "160", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.3", "94.8", "", "", "", "", "94.0"]} -{"pcdb_id": 16133, "brand_name": "Warmflow", "model_name": "Boilerhouse", "model_qualifier": "B120HE", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 33.0, "final_year_of_manufacture": null, "raw": ["016133", "000063", "0", "2013/Mar/28 08:30", "Warmflow Engineering", "Warmflow", "Boilerhouse", "B120HE", "", "2009", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "26", "33", "", "", "88.0", "80.2", "", "58.6", "", "2", "", "", "201", "1", "1", "160", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.7", "94.7", "", "", "", "", "94.0"]} -{"pcdb_id": 16134, "brand_name": "Ariston", "model_name": "Clas HE 38", "model_qualifier": "", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 55.8, "output_kw_max": 30.3, "final_year_of_manufacture": 2013, "raw": ["016134", "000080", "0", "2014/Apr/15 15:00", "Merloni TermoSanitari", "Ariston", "Clas HE 38", "", "47-116-53", "2007", "2013", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "30.3", "30.3", "", "", "87.9", "79.3", "", "55.8", "", "2", "", "", "104", "1", "2", "120", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "96.6", "", "", "", "", "94.9"]} -{"pcdb_id": 16135, "brand_name": "Intergas", "model_name": "Combi Compact HRE 28/24", "model_qualifier": "", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 86.7, "comparative_hot_water_efficiency_pct": 72.3, "output_kw_max": 23.1, "final_year_of_manufacture": null, "raw": ["016135", "000256", "0", "2014/Dec/01 15:18", "Intergas Heating Ltd", "Intergas", "Combi Compact HRE 28/24", "", "", "2009", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "23.1", "23.1", "", "", "88.2", "86.7", "", "72.3", "", "2", "", "", "104", "1", "2", "130", "1.9", "0", "", "", "", "0", "", "", "", "", "1", "7.281", "0.138", "0.0094", "1.1037", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "97.2", "", "", "", "", "95.5"]} -{"pcdb_id": 16136, "brand_name": "Ideal", "model_name": "Logic combi", "model_qualifier": "24", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 69.3, "output_kw_max": 24.2, "final_year_of_manufacture": 2016, "raw": ["016136", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "Logic combi", "24", "47-348-56", "2009", "2016", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "88.4", "87.3", "", "69.3", "", "2", "", "", "104", "1", "2", "146", "1", "0", "", "", "0", "0", "", "", "", "", "1", "7.5959", "0.1755", "0.008", "1.46665", "", "", "", "", "", "1", "1", "0", "0035", "", "", "", "", "", "", "", "", "89.8", "96.9", "", "", "", "", "95.6"]} -{"pcdb_id": 16137, "brand_name": "Ideal", "model_name": "Logic combi", "model_qualifier": "30", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 69.8, "output_kw_max": 24.2, "final_year_of_manufacture": 2016, "raw": ["016137", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "Logic combi", "30", "47-348-57", "2009", "2016", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "88.4", "87.3", "", "69.8", "", "2", "", "", "104", "1", "2", "152", "1", "0", "", "", "0", "0", "", "", "", "", "1", "7.548", "0.1749", "0.0099", "1.41408", "", "", "", "", "", "1", "1", "0", "0035", "", "", "", "", "", "", "", "", "90.0", "96.9", "", "", "", "", "95.6"]} -{"pcdb_id": 16138, "brand_name": "Ideal", "model_name": "Logic combi", "model_qualifier": "35", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 71.0, "output_kw_max": 24.2, "final_year_of_manufacture": 2016, "raw": ["016138", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "Logic combi", "35", "47-348-58", "2009", "2016", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "88.3", "87.3", "", "71.0", "", "2", "", "", "104", "1", "2", "177", "1", "0", "", "", "0", "0", "", "", "", "", "1", "7.4216", "0.171", "0.0087", "1.2937", "", "", "", "", "", "1", "1", "0", "0035", "", "", "", "", "", "", "", "", "89.8", "96.9", "", "", "", "", "95.5"]} -{"pcdb_id": 16139, "brand_name": "Worcester", "model_name": "Greenstar Camray External System", "model_qualifier": "12/18", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 58.7, "output_kw_max": 18.0, "final_year_of_manufacture": 2015, "raw": ["016139", "000035", "0", "2020/Sep/08 10:23", "Bosch Thermotechnology", "Worcester", "Greenstar Camray External System", "12/18", "Greenstar Camray 12/18-ROO-GB Ext Sys", "2009", "2015", "4", "1", "2", "1", "0", "", "", "2", "2", "2", "12", "18", "", "", "88.1", "80.3", "", "58.7", "", "2", "", "", "201", "1", "1", "265", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.4", "94.8", "", "", "", "", "94.2"]} -{"pcdb_id": 16140, "brand_name": "Worcester", "model_name": "Greenstar Camray External System", "model_qualifier": "18/25", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 80.6, "comparative_hot_water_efficiency_pct": 58.9, "output_kw_max": 25.0, "final_year_of_manufacture": 2015, "raw": ["016140", "000035", "0", "2020/Sep/08 10:24", "Bosch Thermotechnology", "Worcester", "Greenstar Camray External System", "18/25", "Greenstar Camray 18/25-ROO0GB Ext Sys", "2009", "2015", "4", "1", "2", "1", "0", "", "", "2", "2", "2", "18", "25", "", "", "88.4", "80.6", "", "58.9", "", "2", "", "", "201", "1", "1", "265", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.5", "95.9", "", "", "", "", "94.8"]} -{"pcdb_id": 16141, "brand_name": "Worcester", "model_name": "Greenstar Camray External System", "model_qualifier": "25/32", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 81.1, "comparative_hot_water_efficiency_pct": 59.3, "output_kw_max": 30.0, "final_year_of_manufacture": 2015, "raw": ["016141", "000035", "0", "2020/Sep/08 10:24", "Bosch Thermotechnology", "Worcester", "Greenstar Camray External System", "25/32", "", "2009", "2015", "4", "1", "2", "1", "0", "", "", "2", "2", "2", "25", "30", "", "", "88.9", "81.1", "", "59.3", "", "2", "", "", "201", "1", "1", "265", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.5", "96.9", "", "", "", "", "95.9"]} -{"pcdb_id": 16142, "brand_name": "Wolf", "model_name": "COB-29", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 59.0, "output_kw_max": 29.6, "final_year_of_manufacture": null, "raw": ["016142", "000240", "0", "2012/Mar/27 10:12", "Wolf", "Wolf", "COB-29", "", "", "2007", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "19.6", "29.6", "", "", "88.6", "80.8", "", "59.0", "", "2", "", "", "201", "1", "2", "73.5", "4.5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.5", "96.5", "", "", "", "", "95.4"]} -{"pcdb_id": 16143, "brand_name": "Wolf", "model_name": "COB-20", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 59.0, "output_kw_max": 20.0, "final_year_of_manufacture": null, "raw": ["016143", "000240", "0", "2012/Mar/27 10:12", "Wolf", "Wolf", "COB-20", "", "", "2007", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "13.9", "20.0", "", "", "88.6", "80.8", "", "59.0", "", "2", "", "", "201", "1", "2", "63.5", "5.9", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "91.0", "96.2", "", "", "", "", "95.2"]} -{"pcdb_id": 16144, "brand_name": "Potterton", "model_name": "Heatmax Combi", "model_qualifier": "24 HE", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 56.1, "output_kw_max": 20.0, "final_year_of_manufacture": 2015, "raw": ["016144", "000005", "0", "2015/Aug/06 12:58", "Baxi Heating", "Potterton", "Heatmax Combi", "24 HE", "GC No. 47-393-27", "2009", "2015", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "20.0", "20.0", "", "", "88.4", "79.8", "", "56.1", "", "2", "", "", "104", "1", "2", "155", "5", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "90.0", "96.9", "", "", "", "", "95.6"]} -{"pcdb_id": 16145, "brand_name": "Potterton", "model_name": "Heatmax Combi", "model_qualifier": "28 HE", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 56.1, "output_kw_max": 24.0, "final_year_of_manufacture": 2015, "raw": ["016145", "000005", "0", "2015/Aug/06 12:58", "Baxi", "Potterton", "Heatmax Combi", "28 HE", "GC No 47-393-28", "2009", "2015", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.0", "24.0", "", "", "88.4", "79.8", "", "56.1", "", "2", "", "", "104", "1", "2", "155", "5", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "90.0", "96.9", "", "", "", "", "95.6"]} -{"pcdb_id": 16146, "brand_name": "Potterton", "model_name": "Heatmax Combi", "model_qualifier": "33 HE", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 56.0, "output_kw_max": 28.0, "final_year_of_manufacture": 2015, "raw": ["016146", "000005", "0", "2015/Aug/06 12:59", "Baxi", "Potterton", "Heatmax Combi", "33 HE", "GC No. 47-393-29", "2009", "2015", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28.0", "28.0", "", "", "88.3", "79.7", "", "56.0", "", "2", "", "", "104", "1", "2", "160", "5", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "90.0", "96.7", "", "", "", "", "95.4"]} -{"pcdb_id": 16147, "brand_name": "Intergas", "model_name": "Combi Compact HRE 24/18", "model_qualifier": "", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 86.6, "comparative_hot_water_efficiency_pct": 72.1, "output_kw_max": 18.2, "final_year_of_manufacture": null, "raw": ["016147", "000256", "0", "2014/Dec/01 15:19", "Intergas Heating Ltd", "Intergas", "Combi Compact HRE 24/18", "", "", "2009", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "18.2", "18.2", "", "", "88.2", "86.6", "", "72.1", "", "2", "", "", "104", "1", "2", "130", "1.9", "0", "", "", "", "0", "", "", "", "", "1", "7.302", "0.141", "0.011", "1.10948", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "97.4", "", "", "", "", "95.6"]} -{"pcdb_id": 16148, "brand_name": "Pro", "model_name": "A28", "model_qualifier": "", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 56.0, "output_kw_max": 19.6, "final_year_of_manufacture": null, "raw": ["016148", "000011", "0", "2009/Jul/29 07:37", "Vokera", "Pro", "A28", "", "47-094-96", "2008", "current", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "19.6", "19.6", "", "", "88.2", "79.6", "", "56.0", "", "2", "", "", "104", "1", "2", "150", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.5", "97.0", "", "", "", "", "95.4"]} -{"pcdb_id": 16149, "brand_name": "Pro", "model_name": "A32", "model_qualifier": "", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 55.9, "output_kw_max": 24.4, "final_year_of_manufacture": null, "raw": ["016149", "000011", "0", "2009/Jul/29 07:37", "Vokera", "Pro", "A32", "", "47-094-97", "2008", "current", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "24.4", "24.4", "", "", "88.2", "79.6", "", "55.9", "", "2", "", "", "104", "1", "2", "150", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.1", "97.1", "", "", "", "", "95.4"]} -{"pcdb_id": 16150, "brand_name": "Pro", "model_name": "A36", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 55.9, "output_kw_max": 29.3, "final_year_of_manufacture": null, "raw": ["016150", "000011", "0", "2009/Jul/29 07:37", "Vokera", "Pro", "A36", "", "47-094-98", "2008", "current", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "29.3", "29.3", "", "", "88.1", "79.5", "", "55.9", "", "2", "", "", "104", "1", "2", "150", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "97.1", "", "", "", "", "95.4"]} -{"pcdb_id": 16151, "brand_name": "Vokera", "model_name": "Mynute", "model_qualifier": "29EHE", "winter_efficiency_pct": 85.2, "summer_efficiency_pct": 76.2, "comparative_hot_water_efficiency_pct": 55.6, "output_kw_max": 28.3, "final_year_of_manufacture": null, "raw": ["016151", "000011", "0", "2012/Mar/27 10:12", "Vokera", "Vokera", "Mynute", "29EHE", "", "2008", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "28.30", "28.30", "", "", "85.2", "76.2", "", "55.6", "", "2", "", "", "102", "1", "2", "150", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "89.6", "", "", "", "", "89.3"]} -{"pcdb_id": 16152, "brand_name": "Vokera", "model_name": "Mynute", "model_qualifier": "25EHE", "winter_efficiency_pct": 85.4, "summer_efficiency_pct": 76.4, "comparative_hot_water_efficiency_pct": 55.8, "output_kw_max": 24.35, "final_year_of_manufacture": null, "raw": ["016152", "000011", "0", "2012/Mar/27 10:12", "Vokera", "Vokera", "Mynute", "25EHE", "", "2008", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "24.35", "24.35", "", "", "85.4", "76.4", "", "55.8", "", "2", "", "", "102", "1", "2", "150", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "90.2", "", "", "", "", "89.7"]} -{"pcdb_id": 16154, "brand_name": "ARCA", "model_name": "Pixel 31 FCR", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 30.2, "final_year_of_manufacture": null, "raw": ["016154", "000261", "0", "2012/Mar/27 10:12", "ARCA", "ARCA", "Pixel 31 FCR", "", "", "2005", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "30.2", "30.2", "", "", "88.5", "79.5", "", "58.1", "", "2", "", "", "102", "1", "2", "150", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "98.0", "", "", "", "", "96.1"]} -{"pcdb_id": 16155, "brand_name": "Intergas", "model_name": "Compact HRE 18 SB", "model_qualifier": "", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 18.2, "final_year_of_manufacture": null, "raw": ["016155", "000256", "0", "2012/Mar/27 10:12", "Intergas Heating Ltd", "Intergas", "Compact HRE 18 SB", "", "", "2009", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18.2", "18.2", "", "", "88.2", "79.2", "", "57.9", "", "2", "", "", "102", "1", "2", "130", "1.9", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "97.4", "", "", "", "", "95.6"]} -{"pcdb_id": 16156, "brand_name": "Intergas", "model_name": "Compact HRE 24 SB", "model_qualifier": "", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 23.1, "final_year_of_manufacture": null, "raw": ["016156", "000256", "0", "2012/Mar/27 10:12", "Intergas Heating Ltd", "Intergas", "Compact HRE 24 SB", "", "", "2009", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "23.1", "23.1", "", "", "88.2", "79.2", "", "57.8", "", "2", "", "", "102", "1", "2", "130", "1.9", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "97.2", "", "", "", "", "95.5"]} -{"pcdb_id": 16157, "brand_name": "Intergas", "model_name": "Compact HRE 30 SB", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 26.6, "final_year_of_manufacture": null, "raw": ["016157", "000256", "0", "2012/Mar/27 10:12", "Intergas Heating Ltd", "Intergas", "Compact HRE 30 SB", "", "", "2009", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "26.6", "26.6", "", "", "88.5", "79.5", "", "58.0", "", "2", "", "", "102", "1", "2", "130", "1.9", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.9", "97.6", "", "", "", "", "95.9"]} -{"pcdb_id": 16159, "brand_name": "ARCA", "model_name": "Pixel 31 FC", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 56.2, "output_kw_max": 30.2, "final_year_of_manufacture": null, "raw": ["016159", "000261", "0", "2009/Jul/30 14:29", "ARCA", "ARCA", "Pixel 31 FC", "", "", "2005", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "30.2", "30.2", "", "", "88.5", "79.9", "", "56.2", "", "2", "", "", "104", "1", "2", "150", "5", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "97.9", "", "", "", "", "96.1"]} -{"pcdb_id": 16161, "brand_name": "ARCA", "model_name": "Pixel 25 FCR", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 24.4, "final_year_of_manufacture": null, "raw": ["016161", "000261", "0", "2012/Mar/27 10:12", "ARCA", "ARCA", "Pixel 25 FCR", "", "", "2005", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24.4", "24.4", "", "", "88.5", "79.5", "", "58.0", "", "2", "", "", "102", "1", "2", "150", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "97.9", "", "", "", "", "96.1"]} -{"pcdb_id": 16164, "brand_name": "ARCA", "model_name": "Pixel 25 FC", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 56.2, "output_kw_max": 24.4, "final_year_of_manufacture": null, "raw": ["016164", "000261", "0", "2009/Jul/30 14:30", "ARCA", "ARCA", "Pixel 25 FC", "", "", "2005", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.4", "24.4", "", "", "88.5", "79.9", "", "56.2", "", "2", "", "", "104", "1", "2", "150", "5", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "97.9", "", "", "", "", "96.1"]} -{"pcdb_id": 16165, "brand_name": "ATAG", "model_name": "A200S", "model_qualifier": "", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 17.6, "final_year_of_manufacture": null, "raw": ["016165", "000227", "0", "2012/Mar/27 10:12", "ATAG Verwarming Nederland BV", "ATAG", "A200S", "", "", "2009", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "17.6", "17.6", "", "", "88.7", "79.7", "", "58.2", "", "2", "", "", "102", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.2", "98.4", "", "", "", "", "96.5"]} -{"pcdb_id": 16166, "brand_name": "ATAG", "model_name": "A200S OV", "model_qualifier": "", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 17.6, "final_year_of_manufacture": null, "raw": ["016166", "000227", "0", "2012/Mar/27 10:12", "ATAG Verwarming Nederland BV", "ATAG", "A200S OV", "", "", "2009", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "17.6", "17.6", "", "", "88.7", "79.7", "", "58.2", "", "2", "", "", "102", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.2", "98.4", "", "", "", "", "96.5"]} -{"pcdb_id": 16167, "brand_name": "ATAG", "model_name": "A203C", "model_qualifier": "", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 56.3, "output_kw_max": 17.6, "final_year_of_manufacture": null, "raw": ["016167", "000227", "0", "2009/Oct/22 11:42", "ATAG Verwarming Nederland BV", "ATAG", "A203C", "", "", "2009", "current", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "17.6", "17.6", "", "", "88.7", "80.1", "", "56.3", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.2", "98.4", "", "", "", "", "96.5"]} -{"pcdb_id": 16169, "brand_name": "ATAG", "model_name": "A320S", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 28.2, "final_year_of_manufacture": null, "raw": ["016169", "000227", "0", "2012/Mar/27 10:12", "ATAG Verwarming Nederland BV", "ATAG", "A320S", "", "", "2009", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "28.2", "28.2", "", "", "88.8", "79.8", "", "58.3", "", "2", "", "", "102", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.2", "98.8", "", "", "", "", "96.8"]} -{"pcdb_id": 16170, "brand_name": "ATAG", "model_name": "A325C", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 56.4, "output_kw_max": 28.2, "final_year_of_manufacture": null, "raw": ["016170", "000227", "0", "2009/Oct/22 11:42", "ATAG Verwarming Nederland BV", "ATAG", "A325C", "", "", "2009", "current", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "28.2", "28.2", "", "", "88.8", "80.2", "", "56.4", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.2", "98.8", "", "", "", "", "96.8"]} -{"pcdb_id": 16171, "brand_name": "ATAG", "model_name": "A325EC", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 56.3, "output_kw_max": 28.2, "final_year_of_manufacture": null, "raw": ["016171", "000227", "0", "2009/Oct/22 11:43", "ATAG Verwarming Nederland BV", "ATAG", "A325EC", "", "", "2009", "current", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "28.2", "28.2", "", "", "88.6", "80.0", "", "56.3", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "98.3", "", "", "", "", "96.4"]} -{"pcdb_id": 16172, "brand_name": "Glow-worm", "model_name": "Betacom 24c", "model_qualifier": "", "winter_efficiency_pct": 85.9, "summer_efficiency_pct": 77.3, "comparative_hot_water_efficiency_pct": 54.4, "output_kw_max": 24.7, "final_year_of_manufacture": null, "raw": ["016172", "000207", "0", "2010/Mar/06 17:48", "Vaillant Group UK", "Glow-worm", "Betacom 24c", "", "", "2008", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24.7", "24.7", "", "", "85.9", "77.3", "", "54.4", "", "2", "1", "", "104", "1", "2", "164", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.4", "91.7", "", "", "", "", "91.1"]} -{"pcdb_id": 16173, "brand_name": "Glow-worm", "model_name": "Betacom 30c", "model_qualifier": "", "winter_efficiency_pct": 86.0, "summer_efficiency_pct": 77.4, "comparative_hot_water_efficiency_pct": 54.5, "output_kw_max": 27.6, "final_year_of_manufacture": null, "raw": ["016173", "000207", "0", "2010/Mar/06 17:48", "Vaillant Group UK", "Glow-worm", "Betacom 30c", "", "", "2008", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "27.6", "27.6", "", "", "86.0", "77.4", "", "54.5", "", "2", "1", "", "104", "1", "2", "164", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.2", "91.7", "", "", "", "", "91.2"]} -{"pcdb_id": 16174, "brand_name": "Heatline", "model_name": "Sargon 18S", "model_qualifier": "", "winter_efficiency_pct": 87.8, "summer_efficiency_pct": 78.8, "comparative_hot_water_efficiency_pct": 57.6, "output_kw_max": 19.5, "final_year_of_manufacture": 2009, "raw": ["016174", "000215", "0", "2012/Mar/27 10:12", "DD Heating", "Heatline", "Sargon 18S", "", "41-157-12", "2008", "2009", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "19.5", "19.5", "", "", "87.8", "78.8", "", "57.6", "", "2", "", "", "102", "1", "2", "175", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "96.4", "", "", "", "", "94.8"]} -{"pcdb_id": 16176, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "15 i System", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 15.0, "final_year_of_manufacture": 2015, "raw": ["016176", "000035", "0", "2020/Sep/08 10:24", "Bosch Thermotechnology", "Worcester", "Greenstar", "15 i System", "", "2009", "2015", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "15", "15", "", "", "89.1", "80.1", "", "58.5", "", "2", "1", "", "102", "1", "2", "140", "9.6", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0305", "", "", "", "", "", "", "", "", "89.7", "99.2", "", "", "", "", "97.4"]} -{"pcdb_id": 16177, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "15 i System", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 15.0, "final_year_of_manufacture": 2015, "raw": ["016177", "000035", "0", "2020/Sep/08 10:25", "Bosch Thermotechnology", "Worcester", "Greenstar", "15 i System", "41-311-84", "2009", "2015", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "15.0", "15.0", "", "", "88.1", "79.1", "", "57.7", "", "2", "", "", "102", "1", "2", "140", "9.6", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0305", "", "", "", "", "", "", "", "", "87.8", "97.0", "", "", "", "", "95.3"]} -{"pcdb_id": 16178, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "18 i System", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 18.0, "final_year_of_manufacture": 2015, "raw": ["016178", "000035", "0", "2020/Sep/08 10:25", "Bosch Thermotechnology", "Worcester", "Greenstar", "18 i System", "", "2009", "2015", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "18.0", "18.0", "", "", "89.1", "80.1", "", "58.5", "", "2", "1", "", "102", "1", "2", "140", "9.6", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0305", "", "", "", "", "", "", "", "", "89.7", "99.2", "", "", "", "", "97.4"]} -{"pcdb_id": 16179, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "18 i System", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 18.0, "final_year_of_manufacture": 2015, "raw": ["016179", "000035", "0", "2020/Sep/08 10:25", "Bosch Thermotechnology", "Worcester", "Greenstar", "18 i System", "41-311-86", "2009", "2015", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18.0", "18.0", "", "", "88.1", "79.1", "", "57.7", "", "2", "", "", "102", "1", "2", "140", "9.6", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0305", "", "", "", "", "", "", "", "", "87.8", "97.0", "", "", "", "", "95.3"]} -{"pcdb_id": 16180, "brand_name": "Viessmann", "model_name": "Vitodens 100 W WB1B", "model_qualifier": "13kW Regular Boiler open vent", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 80.4, "comparative_hot_water_efficiency_pct": 58.7, "output_kw_max": 11.9, "final_year_of_manufacture": null, "raw": ["016180", "000033", "0", "2017/Feb/20 10:57", "Viessmann", "Viessmann", "Vitodens 100 W WB1B", "13kW Regular Boiler open vent", "", "2009", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "11.9", "11.9", "", "", "89.4", "80.4", "", "58.7", "", "2", "1", "", "102", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "", "", "", "", "90.0", "99.8", "", "", "", "", "98.0"]} -{"pcdb_id": 16181, "brand_name": "Viessmann", "model_name": "Vitodens 100 W WB1B", "model_qualifier": "13kW Regular Boiler open vent", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 11.9, "final_year_of_manufacture": null, "raw": ["016181", "000033", "0", "2017/Feb/20 10:57", "Viessmann", "Viessmann", "Vitodens 100 W WB1B", "13kW Regular Boiler open vent", "41-819-21", "2009", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "11.9", "11.9", "", "", "88.3", "79.3", "", "58.0", "", "2", "", "", "102", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "", "", "", "", "88.0", "97.7", "", "", "", "", "95.8"]} -{"pcdb_id": 16182, "brand_name": "Viessmann", "model_name": "Vitodens 100 W WB1B", "model_qualifier": "16kW Regular Boiler open vent", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 80.4, "comparative_hot_water_efficiency_pct": 58.7, "output_kw_max": 14.6, "final_year_of_manufacture": null, "raw": ["016182", "000033", "0", "2017/Feb/20 10:57", "Viessmann", "Viessmann", "Vitodens 100 W WB1B", "16kW Regular Boiler open vent", "", "2009", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "14.6", "14.6", "", "", "89.4", "80.4", "", "58.7", "", "2", "1", "", "102", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "", "", "", "", "90.1", "99.8", "", "", "", "", "98.0"]} -{"pcdb_id": 16183, "brand_name": "Viessmann", "model_name": "Vitodens 100 W WB1B", "model_qualifier": "16kW Regular Boiler open vent", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 14.6, "final_year_of_manufacture": null, "raw": ["016183", "000033", "0", "2017/Feb/20 10:57", "Viessmann", "Viessmann", "Vitodens 100 W WB1B", "16kW Regular Boiler open vent", "41-819-22", "2009", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "14.6", "14.6", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "", "", "", "", "88.1", "97.7", "", "", "", "", "95.9"]} -{"pcdb_id": 16184, "brand_name": "Viessmann", "model_name": "Vitodens 100 W WB1B", "model_qualifier": "19kW Regular Boiler open vent", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 80.4, "comparative_hot_water_efficiency_pct": 58.7, "output_kw_max": 17.3, "final_year_of_manufacture": null, "raw": ["016184", "000033", "0", "2017/Feb/20 10:57", "Viessmann", "Viessmann", "Vitodens 100 W WB1B", "19kW Regular Boiler open vent", "", "2009", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "17.3", "17.3", "", "", "89.4", "80.4", "", "58.7", "", "2", "1", "", "102", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "", "", "", "", "90.0", "99.8", "", "", "", "", "98.0"]} -{"pcdb_id": 16185, "brand_name": "Viessmann", "model_name": "Vitodens 100 W WB1B", "model_qualifier": "19kW Regular Boiler open vent", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 17.3, "final_year_of_manufacture": null, "raw": ["016185", "000033", "0", "2017/Feb/20 10:57", "Viessmann", "Viessmann", "Vitodens 100 W WB1B", "19kW Regular Boiler open vent", "41-819-23", "2009", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "1", "17.3", "17.3", "", "", "88.3", "79.3", "", "58.0", "", "2", "", "", "102", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "", "", "", "", "88.0", "97.7", "", "", "", "", "95.8"]} -{"pcdb_id": 16186, "brand_name": "Viessmann", "model_name": "Vitodens 100 W WB1B", "model_qualifier": "26kW Regular Boiler open vent", "winter_efficiency_pct": 89.6, "summer_efficiency_pct": 80.6, "comparative_hot_water_efficiency_pct": 58.9, "output_kw_max": 23.7, "final_year_of_manufacture": null, "raw": ["016186", "000033", "0", "2017/Feb/20 10:57", "Viessmann", "Viessmann", "Vitodens 100 W WB1B", "26kW Regular Boiler open vent", "", "2009", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "23.7", "23.7", "", "", "89.6", "80.6", "", "58.9", "", "2", "1", "", "102", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "", "", "", "", "90.3", "100.4", "", "", "", "", "98.5"]} -{"pcdb_id": 16187, "brand_name": "Viessmann", "model_name": "Vitodens 100 W WB1B", "model_qualifier": "26kW Regular Boiler open vent", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 23.7, "final_year_of_manufacture": null, "raw": ["016187", "000033", "0", "2012/Aug/28 09:58", "Viessmann", "Viessmann", "Vitodens 100 W WB1B", "26kW Regular Boiler open vent", "41-819-24", "2009", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "23.7", "23.7", "", "", "88.6", "79.6", "", "58.1", "", "2", "", "", "102", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "98.2", "", "", "", "", "96.3"]} -{"pcdb_id": 16189, "brand_name": "Ferroli", "model_name": "DOMIcondens", "model_qualifier": "F28", "winter_efficiency_pct": 86.4, "summer_efficiency_pct": 77.8, "comparative_hot_water_efficiency_pct": 54.7, "output_kw_max": 26.2, "final_year_of_manufacture": 2017, "raw": ["016189", "000097", "0", "2017/Aug/21 13:37", "Ferroli", "Ferroli", "DOMIcondens", "F28", "47-267-46", "2009", "2017", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "26.2", "26.2", "", "", "86.4", "77.8", "", "54.7", "", "2", "", "", "104", "1", "2", "135", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "0", "", "0005", "", "", "", "", "", "", "", "", "86.9", "93.3", "", "", "", "", "92.1"]} -{"pcdb_id": 16190, "brand_name": "Ferroli", "model_name": "DOMIcondens", "model_qualifier": "F28", "winter_efficiency_pct": 87.4, "summer_efficiency_pct": 78.8, "comparative_hot_water_efficiency_pct": 55.4, "output_kw_max": 26.2, "final_year_of_manufacture": 2017, "raw": ["016190", "000097", "0", "2017/Aug/21 13:38", "Ferroli", "Ferroli", "DOMIcondens", "F28", "", "2009", "2017", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "26.2", "26.2", "", "", "87.4", "78.8", "", "55.4", "", "2", "1", "", "104", "1", "2", "135", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "0", "", "0005", "", "", "", "", "", "", "", "", "88.9", "95.3", "", "", "", "", "94.1"]} -{"pcdb_id": 16191, "brand_name": "HRM", "model_name": "X-Ternal System", "model_qualifier": "12/14 Condensing a", "winter_efficiency_pct": 86.9, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 15.7, "final_year_of_manufacture": null, "raw": ["016191", "000098", "0", "2012/Mar/27 10:12", "HRM Boilers", "HRM", "X-Ternal System", "12/14 Condensing a", "", "2009", "current", "4", "2", "2", "1", "0", "", "", "2", "2", "2", "12", "15.7", "", "", "86.9", "79.1", "", "57.8", "", "2", "", "", "201", "1", "1", "110", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.0", "92.3", "", "", "", "", "91.8"]} -{"pcdb_id": 16193, "brand_name": "HRM", "model_name": "Wallstar", "model_qualifier": "12/14 Condensing a", "winter_efficiency_pct": 86.9, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 15.7, "final_year_of_manufacture": null, "raw": ["016193", "000098", "0", "2012/Mar/27 10:12", "HRM Boilers", "HRM", "Wallstar", "12/14 Condensing a", "", "2009", "current", "4", "2", "1", "1", "0", "", "", "2", "2", "2", "12", "15.7", "", "", "86.9", "79.1", "", "57.8", "", "2", "", "", "201", "1", "1", "110", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.0", "92.3", "", "", "", "", "91.8"]} -{"pcdb_id": 16194, "brand_name": "HRM", "model_name": "Wallstar", "model_qualifier": "15/19 Condensing a", "winter_efficiency_pct": 86.8, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 19.0, "final_year_of_manufacture": null, "raw": ["016194", "000098", "0", "2012/Mar/27 10:12", "HRM Boilers", "HRM", "Wallstar", "15/19 Condensing a", "", "2009", "current", "4", "2", "1", "1", "0", "", "", "2", "2", "2", "15", "19", "", "", "86.8", "79.0", "", "57.7", "", "2", "", "", "201", "1", "1", "110", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.5", "91.5", "", "", "", "", "91.5"]} -{"pcdb_id": 16195, "brand_name": "HRM", "model_name": "Wallstar System", "model_qualifier": "15/19 Condensing a", "winter_efficiency_pct": 86.8, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 19.0, "final_year_of_manufacture": null, "raw": ["016195", "000098", "0", "2012/Mar/27 10:12", "HRM Boilers", "HRM", "Wallstar System", "15/19 Condensing a", "", "2009", "current", "4", "2", "1", "1", "0", "", "", "2", "2", "2", "15", "19", "", "", "86.8", "79.0", "", "57.7", "", "2", "", "", "201", "1", "1", "110", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.5", "91.5", "", "", "", "", "91.5"]} -{"pcdb_id": 16196, "brand_name": "HRM", "model_name": "X-Ternal", "model_qualifier": "15/19 Condensing a", "winter_efficiency_pct": 86.8, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 19.0, "final_year_of_manufacture": null, "raw": ["016196", "000098", "0", "2012/Mar/27 10:12", "HRM Boilers", "HRM", "X-Ternal", "15/19 Condensing a", "", "2009", "current", "4", "2", "2", "1", "0", "", "", "2", "2", "2", "15", "19", "", "", "86.8", "79.0", "", "57.7", "", "2", "", "", "201", "1", "1", "110", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.5", "91.5", "", "", "", "", "91.5"]} -{"pcdb_id": 16197, "brand_name": "Biasi", "model_name": "ActivA", "model_qualifier": "25S", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 24.5, "final_year_of_manufacture": null, "raw": ["016197", "000208", "0", "2012/Jun/28 11:08", "Biasi (UK)", "Biasi", "ActivA", "25S", "41-583-12", "2009", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24.5", "24.5", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "140", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.1", "96.9", "", "", "", "", "95.2"]} -{"pcdb_id": 16198, "brand_name": "Biasi", "model_name": "ActivA", "model_qualifier": "18S", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 17.6, "final_year_of_manufacture": null, "raw": ["016198", "000208", "0", "2012/Jun/28 11:08", "Biasi (UK)", "Biasi", "ActivA", "18S", "41-583-11", "2009", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "17.6", "17.6", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "140", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.1", "96.8", "", "", "", "", "95.1"]} -{"pcdb_id": 16200, "brand_name": "Biasi", "model_name": "ActivA", "model_qualifier": "35C", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 56.0, "output_kw_max": 29.2, "final_year_of_manufacture": null, "raw": ["016200", "000208", "0", "2011/Sep/30 11:49", "Biasi (UK)", "Biasi", "ActivA", "35C", "47-583-23", "2009", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "29.2", "29.2", "", "", "88.2", "79.6", "", "56.0", "", "2", "", "", "104", "1", "2", "140", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.1", "97.3", "", "", "", "", "95.6"]} -{"pcdb_id": 16201, "brand_name": "Biasi", "model_name": "ActivA", "model_qualifier": "30C", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 55.9, "output_kw_max": 24.5, "final_year_of_manufacture": null, "raw": ["016201", "000208", "0", "2011/Sep/30 11:49", "Biasi (UK)", "Biasi", "ActivA", "30C", "47-583-22", "2009", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.5", "24.5", "", "", "88.0", "79.4", "", "55.9", "", "2", "", "", "104", "1", "2", "140", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.1", "96.9", "", "", "", "", "95.2"]} -{"pcdb_id": 16202, "brand_name": "Biasi", "model_name": "ActivA", "model_qualifier": "25C", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 56.0, "output_kw_max": 19.5, "final_year_of_manufacture": null, "raw": ["016202", "000208", "0", "2011/Sep/30 11:49", "Biasi (UK)", "Biasi", "ActivA", "25C", "47-583-21", "2009", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "19.5", "19.5", "", "", "88.2", "79.6", "", "56.0", "", "2", "", "", "104", "1", "2", "140", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.1", "97.3", "", "", "", "", "95.6"]} -{"pcdb_id": 16203, "brand_name": "Biasi", "model_name": "ActivA", "model_qualifier": "30S", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 29.2, "final_year_of_manufacture": null, "raw": ["016203", "000208", "0", "2012/Jun/28 11:08", "Biasi (UK)", "Biasi", "ActivA", "30S", "41-583-13", "2009", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "29.2", "29.2", "", "", "88.2", "79.2", "", "57.9", "", "2", "", "", "102", "1", "2", "140", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.1", "97.3", "", "", "", "", "95.6"]} -{"pcdb_id": 16204, "brand_name": "Biasi", "model_name": "ActivA", "model_qualifier": "25S", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 24.5, "final_year_of_manufacture": null, "raw": ["016204", "000208", "0", "2012/Mar/27 10:12", "Biasi (UK)", "Biasi", "ActivA", "25S", "", "2009", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "24.5", "24.5", "", "", "89.0", "80.0", "", "58.5", "", "2", "1", "", "102", "1", "2", "140", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.1", "99.0", "", "", "", "", "97.3"]} -{"pcdb_id": 16205, "brand_name": "Biasi", "model_name": "ActivA", "model_qualifier": "18S", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 17.6, "final_year_of_manufacture": null, "raw": ["016205", "000208", "0", "2012/Mar/27 10:12", "Biasi (UK)", "Biasi", "ActivA", "18S", "", "2009", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "17.6", "17.6", "", "", "89.0", "80.0", "", "58.4", "", "2", "1", "", "102", "1", "2", "140", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.1", "98.9", "", "", "", "", "97.2"]} -{"pcdb_id": 16206, "brand_name": "Biasi", "model_name": "ActivA", "model_qualifier": "35C", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 80.6, "comparative_hot_water_efficiency_pct": 56.7, "output_kw_max": 29.2, "final_year_of_manufacture": null, "raw": ["016206", "000208", "0", "2009/Sep/24 12:10", "Biasi (UK)", "Biasi", "ActivA", "35C", "", "2009", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "29.2", "29.2", "", "", "89.2", "80.6", "", "56.7", "", "2", "1", "", "104", "1", "2", "140", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.1", "99.5", "", "", "", "", "97.7"]} -{"pcdb_id": 16207, "brand_name": "Biasi", "model_name": "ActivA", "model_qualifier": "30C", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.4, "comparative_hot_water_efficiency_pct": 56.6, "output_kw_max": 24.5, "final_year_of_manufacture": null, "raw": ["016207", "000208", "0", "2009/Sep/24 12:09", "Biasi (UK)", "Biasi", "ActivA", "30C", "", "2009", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24.5", "24.5", "", "", "89.0", "80.4", "", "56.6", "", "2", "1", "", "104", "1", "2", "140", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.1", "99.0", "", "", "", "", "97.3"]} -{"pcdb_id": 16208, "brand_name": "Biasi", "model_name": "ActivA", "model_qualifier": "25C", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 80.6, "comparative_hot_water_efficiency_pct": 56.7, "output_kw_max": 19.5, "final_year_of_manufacture": null, "raw": ["016208", "000208", "0", "2009/Sep/24 12:09", "Biasi (UK)", "Biasi", "ActivA", "25C", "", "2009", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "19.5", "19.5", "", "", "89.2", "80.6", "", "56.7", "", "2", "1", "", "104", "1", "2", "140", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.1", "99.5", "", "", "", "", "97.7"]} -{"pcdb_id": 16209, "brand_name": "Biasi", "model_name": "ActivA", "model_qualifier": "30S", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 29.2, "final_year_of_manufacture": null, "raw": ["016209", "000208", "0", "2012/Mar/27 10:12", "Biasi (UK)", "Biasi", "ActivA", "30S", "", "2009", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "29.2", "29.2", "", "", "89.2", "80.2", "", "58.6", "", "2", "1", "", "102", "1", "2", "140", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.1", "99.5", "", "", "", "", "97.7"]} -{"pcdb_id": 16210, "brand_name": "Ideal", "model_name": "Logic+ combi", "model_qualifier": "30", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 69.8, "output_kw_max": 24.2, "final_year_of_manufacture": 2016, "raw": ["016210", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "Logic+ combi", "30", "47-348-66", "2009", "2016", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "88.4", "87.3", "", "69.8", "", "2", "", "", "104", "1", "2", "152", "1", "0", "", "", "0", "0", "", "", "", "", "1", "7.548", "0.1749", "0.0099", "1.41408", "", "", "", "", "", "1", "1", "0", "0035", "", "", "", "", "", "", "", "", "90.0", "96.9", "", "", "", "", "95.6"]} -{"pcdb_id": 16211, "brand_name": "Ideal", "model_name": "Logic+ combi", "model_qualifier": "35", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 71.0, "output_kw_max": 24.2, "final_year_of_manufacture": 2016, "raw": ["016211", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "Logic+ combi", "35", "47-348-67", "2009", "2016", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "88.3", "87.3", "", "71.0", "", "2", "", "", "104", "1", "2", "177", "1", "0", "", "", "0", "0", "", "", "", "", "1", "7.4216", "0.171", "0.0087", "1.2937", "", "", "", "", "", "1", "1", "0", "0035", "", "", "", "", "", "", "", "", "89.8", "96.9", "", "", "", "", "95.5"]} -{"pcdb_id": 16212, "brand_name": "Ideal", "model_name": "Logic+ combi", "model_qualifier": "24", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 69.3, "output_kw_max": 24.2, "final_year_of_manufacture": 2016, "raw": ["016212", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "Logic+ combi", "24", "47-348-65", "2009", "2016", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "88.4", "87.3", "", "69.3", "", "2", "", "", "104", "1", "2", "146", "1", "0", "", "", "0", "0", "", "", "", "", "1", "7.5959", "0.1755", "0.008", "1.46665", "", "", "", "", "", "1", "1", "0", "0035", "", "", "", "", "", "", "", "", "89.8", "96.9", "", "", "", "", "95.6"]} -{"pcdb_id": 16213, "brand_name": "Johnson & Starley", "model_name": "RenoXtra", "model_qualifier": "30CA", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 56.4, "output_kw_max": 24.8, "final_year_of_manufacture": null, "raw": ["016213", "000239", "0", "2012/Feb/24 10:18", "Johnson & Starley", "Johnson & Starley", "RenoXtra", "30CA", "", "2008", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.8", "24.8", "", "", "88.8", "80.2", "", "56.4", "", "2", "", "", "104", "1", "2", "170", "4.59", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "98.8", "", "", "", "", "96.8"]} -{"pcdb_id": 16214, "brand_name": "Baxi", "model_name": "Duo-tec Combi", "model_qualifier": "24 HE LPG", "winter_efficiency_pct": 90.4, "summer_efficiency_pct": 81.8, "comparative_hot_water_efficiency_pct": 57.5, "output_kw_max": 20.0, "final_year_of_manufacture": 2012, "raw": ["016214", "000005", "0", "2013/May/07 10:36", "Baxi Heating UK", "Baxi", "Duo-tec Combi", "24 HE LPG", "GC No. 47-075-48", "2009", "2012", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "20.0", "20.0", "", "", "90.4", "81.8", "", "57.5", "", "2", "0", "", "104", "1", "2", "155", "4.76", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "92.0", "99.0", "", "", "", "", "97.7"]} -{"pcdb_id": 16215, "brand_name": "Baxi", "model_name": "Duo-tec Combi", "model_qualifier": "33 HE LPG", "winter_efficiency_pct": 90.3, "summer_efficiency_pct": 81.7, "comparative_hot_water_efficiency_pct": 57.5, "output_kw_max": 28.0, "final_year_of_manufacture": 2012, "raw": ["016215", "000005", "0", "2013/May/07 10:36", "Baxi Heating UK", "Baxi", "Duo-tec Combi", "33 HE LPG", "GC No. 47-075-49", "2009", "2012", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "28.0", "28.0", "", "", "90.3", "81.7", "", "57.5", "", "2", "0", "", "104", "1", "2", "160", "4.74", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "92.0", "98.8", "", "", "", "", "97.5"]} -{"pcdb_id": 16216, "brand_name": "Baxi", "model_name": "Megaflo System", "model_qualifier": "18 HE LPG", "winter_efficiency_pct": 90.4, "summer_efficiency_pct": 81.4, "comparative_hot_water_efficiency_pct": 59.4, "output_kw_max": 18.0, "final_year_of_manufacture": 2012, "raw": ["016216", "000005", "0", "2013/May/07 10:36", "Baxi Heating UK", "Baxi", "Megaflo System", "18 HE LPG", "GC No. 47-075-61", "2009", "2012", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "18.0", "18.0", "", "", "90.4", "81.4", "", "59.4", "", "2", "0", "", "102", "1", "2", "140", "4.76", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "91.9", "99.0", "", "", "", "", "97.7"]} -{"pcdb_id": 16217, "brand_name": "Baxi", "model_name": "Megaflo System", "model_qualifier": "28 HE LPG", "winter_efficiency_pct": 90.3, "summer_efficiency_pct": 81.3, "comparative_hot_water_efficiency_pct": 59.4, "output_kw_max": 28.0, "final_year_of_manufacture": 2012, "raw": ["016217", "000005", "0", "2013/May/07 10:37", "Baxi Heating UK", "Baxi", "Megaflo System", "28 HE LPG", "GC No 47-075-62", "2009", "2012", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "28", "28", "", "", "90.3", "81.3", "", "59.4", "", "2", "0", "", "102", "1", "2", "160", "4.73", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "91.9", "98.8", "", "", "", "", "97.5"]} -{"pcdb_id": 16218, "brand_name": "Baxi", "model_name": "Megaflo System", "model_qualifier": "32 HE LPG", "winter_efficiency_pct": 90.3, "summer_efficiency_pct": 81.3, "comparative_hot_water_efficiency_pct": 59.4, "output_kw_max": 32.0, "final_year_of_manufacture": 2012, "raw": ["016218", "000005", "0", "2013/May/07 10:37", "Baxi Heating UK", "Baxi", "Megaflo System", "32 HE LPG", "GC No. 47-075-63", "2009", "2012", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "32.0", "32.0", "", "", "90.3", "81.3", "", "59.4", "", "2", "0", "", "102", "1", "2", "160", "4.74", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "91.9", "98.8", "", "", "", "", "97.5"]} -{"pcdb_id": 16219, "brand_name": "Baxi", "model_name": "Bermuda BBU", "model_qualifier": "15 HE", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 15.0, "final_year_of_manufacture": 2015, "raw": ["016219", "000005", "0", "2015/Aug/06 11:55", "Baxi Heating UK", "Baxi", "Bermuda BBU", "15 HE", "GC No. 44-075-09", "2009", "2015", "1", "4", "1", "1", "0", "", "", "2", "2", "2", "15.0", "15.0", "", "", "88.1", "79.1", "", "57.8", "", "2", "", "", "102", "1", "2", "112", "9.7", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "97.0", "", "", "", "", "95.3"]} -{"pcdb_id": 16220, "brand_name": "Firebird", "model_name": "Silver System CR20", "model_qualifier": "", "winter_efficiency_pct": 87.7, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 20.0, "final_year_of_manufacture": 2010, "raw": ["016220", "000047", "0", "2012/Mar/27 10:12", "Firebird Boilers", "Firebird", "Silver System CR20", "", "", "2009", "2010", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "15", "20", "", "", "87.7", "79.9", "", "58.3", "", "2", "", "", "201", "1", "1", "38", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.6", "93.6", "", "", "", "", "93.2"]} -{"pcdb_id": 16221, "brand_name": "Firebird", "model_name": "Silver System CR26", "model_qualifier": "", "winter_efficiency_pct": 87.4, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 26.0, "final_year_of_manufacture": 2010, "raw": ["016221", "000047", "0", "2012/Mar/27 10:12", "Firebird Boilers", "Firebird", "Silver System CR26", "", "", "2009", "2010", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "20", "26", "", "", "87.4", "79.6", "", "58.1", "", "2", "", "", "201", "1", "1", "38", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.8", "92.8", "", "", "", "", "92.6"]} -{"pcdb_id": 16222, "brand_name": "Firebird", "model_name": "Silver System CR35", "model_qualifier": "", "winter_efficiency_pct": 86.2, "summer_efficiency_pct": 78.4, "comparative_hot_water_efficiency_pct": 57.3, "output_kw_max": 35.0, "final_year_of_manufacture": 2010, "raw": ["016222", "000047", "0", "2012/Mar/27 10:12", "Firebird Boilers", "Firebird", "Silver System CR35", "", "", "2009", "2010", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "26", "35", "", "", "86.2", "78.4", "", "57.3", "", "2", "", "", "201", "1", "1", "38", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "89.3", "91.1", "", "", "", "", "90.7"]} -{"pcdb_id": 16223, "brand_name": "Thermeco", "model_name": "12-20 Slimline", "model_qualifier": "12-20 BFILC", "winter_efficiency_pct": 87.8, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 20.0, "final_year_of_manufacture": null, "raw": ["016223", "000051", "0", "2012/Mar/27 10:12", "GAH Heating Products", "Thermeco", "12-20 Slimline", "12-20 BFILC", "", "2009", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "12", "20", "", "", "87.8", "80.0", "", "58.5", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.4", "94.2", "", "", "", "", "93.6"]} -{"pcdb_id": 16224, "brand_name": "Fondital", "model_name": "Tahiti Condensing KR 55 Line Tech", "model_qualifier": "", "winter_efficiency_pct": 89.5, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 58.8, "output_kw_max": 53.5, "final_year_of_manufacture": null, "raw": ["016224", "000250", "0", "2012/Mar/27 10:12", "Fondital", "Fondital", "Tahiti Condensing KR 55 Line Tech", "", "", "2008", "current", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "53.5", "53.5", "", "", "89.5", "80.5", "", "58.8", "", "2", "1", "", "102", "1", "2", "245", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.6", "100.3", "", "", "", "", "98.3"]} -{"pcdb_id": 16225, "brand_name": "Fondital", "model_name": "Tahiti Condensing KR 55 Line Tech", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 53.5, "final_year_of_manufacture": null, "raw": ["016225", "000250", "0", "2012/Mar/27 10:12", "Fondital", "Fondital", "Tahiti Condensing KR 55 Line Tech", "", "", "2008", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "53.5", "53.5", "", "", "88.5", "79.5", "", "58.0", "", "2", "", "", "102", "1", "2", "245", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.7", "98.1", "", "", "", "", "96.1"]} -{"pcdb_id": 16226, "brand_name": "Sime", "model_name": "Murelle EV HE", "model_qualifier": "30/55", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 81.8, "comparative_hot_water_efficiency_pct": 47.2, "output_kw_max": 28.9, "final_year_of_manufacture": 2018, "raw": ["016226", "000213", "0", "2024/Jan/31 10:17", "Fonderie Sime S.p.A.", "Sime", "Murelle EV HE", "30/55", "", "2009", "2018", "2", "2", "1", "2", "0", "", "", "2", "3", "2", "28.9", "28.9", "", "", "89.1", "81.8", "", "47.2", "", "2", "1", "", "106", "1", "2", "115", "8", "2", "1", "0", "48", "0", "20", "5", "60", "275", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.6", "98.9", "", "", "", "", "97.3"]} -{"pcdb_id": 16227, "brand_name": "Sime", "model_name": "Murelle EV HE", "model_qualifier": "30/55", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 46.7, "output_kw_max": 28.9, "final_year_of_manufacture": 2018, "raw": ["016227", "000213", "0", "2024/Jan/31 10:17", "Fonderie Sime S.p.A.", "Sime", "Murelle EV HE", "30/55", "", "2009", "2018", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "28.9", "28.9", "", "", "88.1", "80.8", "", "46.7", "", "2", "", "", "106", "1", "2", "115", "8", "2", "1", "0", "48", "0", "20", "5", "60", "275", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.7", "96.8", "", "", "", "", "95.2"]} -{"pcdb_id": 16228, "brand_name": "Sime", "model_name": "Murelle EV HE", "model_qualifier": "25/55", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 80.7, "comparative_hot_water_efficiency_pct": 46.6, "output_kw_max": 23.9, "final_year_of_manufacture": 2018, "raw": ["016228", "000213", "0", "2024/Jan/31 10:17", "Fonderie Sime S.p.A.", "Sime", "Murelle EV HE", "25/55", "", "2009", "2018", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "23.9", "23.9", "", "", "88.0", "80.7", "", "46.6", "", "2", "", "", "106", "1", "2", "115", "8", "2", "1", "0", "48", "0", "20", "5", "60", "275", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "96.6", "", "", "", "", "95.0"]} -{"pcdb_id": 16229, "brand_name": "Sime", "model_name": "Murelle EV HE", "model_qualifier": "25/55", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 81.7, "comparative_hot_water_efficiency_pct": 47.2, "output_kw_max": 23.9, "final_year_of_manufacture": 2018, "raw": ["016229", "000213", "0", "2024/Jan/31 10:17", "Fonderie Sime S.p.A.", "Sime", "Murelle EV HE", "25/55", "", "2009", "2018", "2", "2", "1", "2", "0", "", "", "2", "3", "2", "23.9", "23.9", "", "", "89.0", "81.7", "", "47.2", "", "2", "1", "", "106", "1", "2", "115", "8", "2", "1", "0", "48", "0", "20", "5", "60", "275", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.3", "98.7", "", "", "", "", "97.1"]} -{"pcdb_id": 16230, "brand_name": "Sime", "model_name": "Murelle EV HE", "model_qualifier": "35", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 55.8, "output_kw_max": 34.1, "final_year_of_manufacture": 2018, "raw": ["016230", "000213", "0", "2018/Mar/05 16:35", "Fonderie Sime S.p.A.", "Sime", "Murelle EV HE", "35", "", "2009", "2018", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "34.1", "34.1", "", "", "88.0", "79.4", "", "55.8", "", "2", "", "", "104", "1", "2", "140", "8", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.5", "96.2", "", "", "", "", "94.9"]} -{"pcdb_id": 16231, "brand_name": "Sime", "model_name": "Murelle EV HE", "model_qualifier": "35", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.4, "comparative_hot_water_efficiency_pct": 56.6, "output_kw_max": 34.1, "final_year_of_manufacture": 2018, "raw": ["016231", "000213", "0", "2018/Mar/05 16:35", "Fonderie Sime S.p.A.", "Sime", "Murelle EV HE", "35", "", "2009", "2018", "2", "2", "1", "2", "0", "", "", "2", "3", "2", "34.1", "34.1", "", "", "89.0", "80.4", "", "56.6", "", "2", "1", "", "104", "1", "2", "140", "8", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "91.5", "98.4", "", "", "", "", "97.1"]} -{"pcdb_id": 16232, "brand_name": "Sime", "model_name": "Murelle EV HE", "model_qualifier": "30", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 56.0, "output_kw_max": 28.9, "final_year_of_manufacture": 2018, "raw": ["016232", "000213", "0", "2018/Mar/05 14:23", "Fonderie Sime S.p.A.", "Sime", "Murelle EV HE", "30", "", "2009", "2018", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "28.9", "28.9", "", "", "88.2", "79.6", "", "56.0", "", "2", "", "", "104", "1", "2", "130", "8", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.7", "97.0", "", "", "", "", "95.4"]} -{"pcdb_id": 16233, "brand_name": "Sime", "model_name": "Murelle EV HE", "model_qualifier": "30", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 80.6, "comparative_hot_water_efficiency_pct": 56.7, "output_kw_max": 28.9, "final_year_of_manufacture": 2018, "raw": ["016233", "000213", "0", "2018/Mar/05 14:24", "Fonderie Sime S.p.A.", "Sime", "Murelle EV HE", "30", "", "2009", "2018", "2", "2", "1", "2", "0", "", "", "2", "3", "2", "28.9", "28.9", "", "", "89.2", "80.6", "", "56.7", "", "2", "1", "", "104", "1", "2", "130", "8", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.6", "99.2", "", "", "", "", "97.6"]} -{"pcdb_id": 16234, "brand_name": "Sime", "model_name": "Murelle EV HE", "model_qualifier": "25", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 56.0, "output_kw_max": 23.9, "final_year_of_manufacture": 2018, "raw": ["016234", "000213", "0", "2018/Mar/05 14:19", "Fonderie Sime S.p.A.", "Sime", "Murelle EV HE", "25", "", "2009", "2018", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "23.9", "23.9", "", "", "88.2", "79.6", "", "56.0", "", "2", "", "", "104", "1", "2", "125", "8", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.5", "97.1", "", "", "", "", "95.5"]} -{"pcdb_id": 16235, "brand_name": "Sime", "model_name": "Murelle EV HE", "model_qualifier": "25", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 80.6, "comparative_hot_water_efficiency_pct": 56.7, "output_kw_max": 23.9, "final_year_of_manufacture": 2018, "raw": ["016235", "000213", "0", "2018/Mar/05 14:20", "Fonderie Sime S.p.A.", "Sime", "Murelle EV HE", "25", "", "2009", "2018", "2", "2", "1", "2", "0", "", "", "2", "3", "2", "23.9", "23.9", "", "", "89.2", "80.6", "", "56.7", "", "2", "1", "", "104", "1", "2", "125", "8", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.4", "99.3", "", "", "", "", "97.6"]} -{"pcdb_id": 16236, "brand_name": "Sime", "model_name": "Murelle EV HE", "model_qualifier": "35 System", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 34.1, "final_year_of_manufacture": 2018, "raw": ["016236", "000213", "0", "2018/Mar/05 16:35", "Fonderie Sime S.p.A.", "Sime", "Murelle EV HE", "35 System", "", "2009", "2018", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "34.1", "34.1", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "140", "8", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.5", "96.2", "", "", "", "", "94.9"]} -{"pcdb_id": 16237, "brand_name": "Sime", "model_name": "Murelle EV HE", "model_qualifier": "35 System", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 34.1, "final_year_of_manufacture": 2018, "raw": ["016237", "000213", "0", "2018/Mar/05 16:36", "Fonderie Sime S.p.A.", "Sime", "Murelle EV HE", "35 System", "", "2009", "2018", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "34.1", "34.1", "", "", "89.0", "80.0", "", "58.4", "", "2", "1", "", "102", "1", "2", "140", "8", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "91.5", "98.4", "", "", "", "", "97.1"]} -{"pcdb_id": 16238, "brand_name": "Sime", "model_name": "Murelle EV HE", "model_qualifier": "30 System", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 28.9, "final_year_of_manufacture": 2018, "raw": ["016238", "000213", "0", "2018/Mar/05 14:25", "Fonderie Sime S.p.A.", "Sime", "Murelle EV HE", "30 System", "", "2009", "2018", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "28.9", "28.9", "", "", "88.2", "79.2", "", "57.9", "", "2", "", "", "102", "1", "2", "130", "8", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.7", "97.0", "", "", "", "", "95.4"]} -{"pcdb_id": 16239, "brand_name": "Sime", "model_name": "Murelle EV HE", "model_qualifier": "30 System", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 28.9, "final_year_of_manufacture": 2018, "raw": ["016239", "000213", "0", "2018/Mar/05 16:32", "Fonderie Sime S.p.A.", "Sime", "Murelle EV HE", "30 System", "", "2009", "2018", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "28.9", "28.9", "", "", "89.2", "80.2", "", "58.6", "", "2", "1", "", "102", "1", "2", "130", "8", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.6", "99.2", "", "", "", "", "97.6"]} -{"pcdb_id": 16240, "brand_name": "Sime", "model_name": "Murelle EV HE", "model_qualifier": "25 System", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 23.9, "final_year_of_manufacture": 2018, "raw": ["016240", "000213", "0", "2018/Mar/05 14:20", "Fonderie Sime S.p.A.", "Sime", "Murelle EV HE", "25 System", "", "2009", "2018", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "23.9", "23.9", "", "", "88.2", "79.2", "", "57.9", "", "2", "", "", "102", "1", "2", "125", "8", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.5", "97.1", "", "", "", "", "95.5"]} -{"pcdb_id": 16241, "brand_name": "Sime", "model_name": "Murelle EV HE", "model_qualifier": "25 System", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 23.9, "final_year_of_manufacture": 2018, "raw": ["016241", "000213", "0", "2018/Mar/05 14:21", "Fonderie Sime S.p.A.", "Sime", "Murelle EV HE", "25 System", "", "2009", "2018", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "23.9", "23.9", "", "", "89.2", "80.2", "", "58.6", "", "2", "1", "", "102", "1", "2", "125", "8", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.4", "99.3", "", "", "", "", "97.6"]} -{"pcdb_id": 16242, "brand_name": "Sime", "model_name": "Murelle EV HE", "model_qualifier": "20 System", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 19.0, "final_year_of_manufacture": 2018, "raw": ["016242", "000213", "0", "2018/Mar/05 14:18", "Fonderie Sime S.p.A.", "Sime", "Murelle EV HE", "20 System", "", "2009", "2018", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "19", "19", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "120", "8", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.2", "96.8", "", "", "", "", "95.1"]} -{"pcdb_id": 16243, "brand_name": "Sime", "model_name": "Murelle EV HE", "model_qualifier": "20 System", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 19.0, "final_year_of_manufacture": 2018, "raw": ["016243", "000213", "0", "2018/Mar/05 14:18", "Fonderie Sime S.p.A.", "Sime", "Murelle EV HE", "20 System", "", "2009", "2018", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "19", "19", "", "", "89.0", "80.0", "", "58.5", "", "2", "1", "", "102", "1", "2", "120", "8", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.2", "98.9", "", "", "", "", "97.3"]} -{"pcdb_id": 16244, "brand_name": "Sime", "model_name": "Murelle EV HE", "model_qualifier": "12 System", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 11.7, "final_year_of_manufacture": 2018, "raw": ["016244", "000213", "0", "2018/Mar/05 14:15", "Fonderie Sime S.p.A.", "Sime", "Murelle EV HE", "12 System", "", "2009", "2018", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "11.7", "11.7", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "110", "8", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.2", "96.6", "", "", "", "", "95.0"]} -{"pcdb_id": 16245, "brand_name": "Sime", "model_name": "Murelle EV HE", "model_qualifier": "12 System", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 11.7, "final_year_of_manufacture": 2018, "raw": ["016245", "000213", "0", "2018/Mar/05 14:16", "Fonderie Sime S.p.A.", "Sime", "Murelle EV HE", "12 System", "", "2009", "2018", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "11.7", "11.7", "", "", "89.0", "80.0", "", "58.4", "", "2", "1", "", "102", "1", "2", "110", "8", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.2", "98.7", "", "", "", "", "97.1"]} -{"pcdb_id": 16246, "brand_name": "Sime", "model_name": "Murelle EV HE", "model_qualifier": "12 T", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 11.7, "final_year_of_manufacture": 2018, "raw": ["016246", "000213", "0", "2018/Mar/05 14:16", "Fonderie Sime S.p.A.", "Sime", "Murelle EV HE", "12 T", "", "2009", "2018", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "11.7", "11.7", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "115", "8", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.2", "96.6", "", "", "", "", "95.0"]} -{"pcdb_id": 16247, "brand_name": "Sime", "model_name": "Murelle EV HE", "model_qualifier": "12 T", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 11.7, "final_year_of_manufacture": 2018, "raw": ["016247", "000213", "0", "2018/Mar/05 14:17", "Fonderie Sime S.p.A.", "Sime", "Murelle EV HE", "12 T", "", "2009", "2018", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "11.7", "11.7", "", "", "89.0", "80.0", "", "58.4", "", "2", "1", "", "102", "1", "2", "115", "8", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.2", "98.7", "", "", "", "", "97.1"]} -{"pcdb_id": 16248, "brand_name": "Sime", "model_name": "Murelle EV HE", "model_qualifier": "20 T", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 19.0, "final_year_of_manufacture": 2018, "raw": ["016248", "000213", "0", "2018/Mar/05 14:17", "Fonderie Sime S.p.A.", "Sime", "Murelle EV HE", "20 T", "", "2009", "2018", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "19.0", "19.0", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "125", "8", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.2", "96.8", "", "", "", "", "95.1"]} -{"pcdb_id": 16249, "brand_name": "Sime", "model_name": "Murelle EV HE", "model_qualifier": "20 T", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 19.0, "final_year_of_manufacture": 2018, "raw": ["016249", "000213", "0", "2018/Mar/05 14:19", "Fonderie Sime S.p.A.", "Sime", "Murelle EV HE", "20 T", "", "2009", "2018", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "19", "19", "", "", "89.0", "80.0", "", "58.5", "", "2", "1", "", "102", "1", "2", "125", "8", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.2", "98.9", "", "", "", "", "97.3"]} -{"pcdb_id": 16250, "brand_name": "Sime", "model_name": "Murelle EV HE", "model_qualifier": "25 T", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 23.9, "final_year_of_manufacture": 2018, "raw": ["016250", "000213", "0", "2018/Mar/05 14:21", "Fonderie Sime S.p.A.", "Sime", "Murelle EV HE", "25 T", "", "2009", "2018", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "23.9", "23.9", "", "", "88.2", "79.2", "", "57.9", "", "2", "", "", "102", "1", "2", "130", "8", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.5", "97.1", "", "", "", "", "95.5"]} -{"pcdb_id": 16251, "brand_name": "Sime", "model_name": "Murelle EV HE", "model_qualifier": "25 T", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 23.9, "final_year_of_manufacture": 2018, "raw": ["016251", "000213", "0", "2018/Mar/05 14:22", "Fonderie Sime S.p.A.", "Sime", "Murelle EV HE", "25 T", "", "2009", "2018", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "23.9", "23.9", "", "", "89.2", "80.2", "", "58.6", "", "2", "1", "", "102", "1", "2", "130", "8", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.4", "99.3", "", "", "", "", "97.6"]} -{"pcdb_id": 16252, "brand_name": "Sime", "model_name": "Murelle EV HE", "model_qualifier": "30 T", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 28.9, "final_year_of_manufacture": 2018, "raw": ["016252", "000213", "0", "2018/Mar/05 16:33", "Fonderie Sime S.p.A.", "Sime", "Murelle EV HE", "30 T", "", "2009", "2018", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "28.9", "28.9", "", "", "88.2", "79.2", "", "57.9", "", "2", "", "", "102", "1", "2", "135", "8", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.7", "97.0", "", "", "", "", "95.4"]} -{"pcdb_id": 16253, "brand_name": "Sime", "model_name": "Murelle EV HE", "model_qualifier": "30 T", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 28.9, "final_year_of_manufacture": 2018, "raw": ["016253", "000213", "0", "2018/Mar/05 16:33", "Fonderie Sime S.p.A.", "Sime", "Murelle EV HE", "30 T", "", "2009", "2018", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "28.9", "28.9", "", "", "89.2", "80.2", "", "58.6", "", "2", "1", "", "102", "1", "2", "135", "8", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.6", "99.2", "", "", "", "", "97.6"]} -{"pcdb_id": 16254, "brand_name": "Sime", "model_name": "Murelle EV HE", "model_qualifier": "35 T", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 34.1, "final_year_of_manufacture": 2018, "raw": ["016254", "000213", "0", "2018/Mar/05 16:36", "Fonderie Sime S.p.A.", "Sime", "Murelle EV HE", "35 T", "", "2009", "2018", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "34.1", "34.1", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "145", "8", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.5", "96.2", "", "", "", "", "94.9"]} -{"pcdb_id": 16255, "brand_name": "Sime", "model_name": "Murelle EV HE", "model_qualifier": "35 T", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 34.1, "final_year_of_manufacture": 2018, "raw": ["016255", "000213", "0", "2018/Mar/05 16:37", "Fonderie Sime S.p.A.", "Sime", "Murelle EV HE", "35 T", "", "2009", "2018", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "34.1", "34.1", "", "", "89.0", "80.0", "", "58.4", "", "2", "1", "", "102", "1", "2", "145", "8", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "91.5", "98.4", "", "", "", "", "97.1"]} -{"pcdb_id": 16256, "brand_name": "Sime", "model_name": "Format DGT HE", "model_qualifier": "25/15", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 55.8, "output_kw_max": 19.5, "final_year_of_manufacture": 2018, "raw": ["016256", "000213", "0", "2018/Feb/28 16:52", "Fonderie Sime S.p.A.", "Sime", "Format DGT HE", "25/15", "", "2009", "2018", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "19.5", "19.5", "", "", "88.0", "79.4", "", "55.8", "", "2", "", "", "104", "1", "2", "125", "8", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "96.9", "", "", "", "", "95.1"]} -{"pcdb_id": 16257, "brand_name": "Sime", "model_name": "Format DGT HE", "model_qualifier": "25/15", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.4, "comparative_hot_water_efficiency_pct": 56.5, "output_kw_max": 19.5, "final_year_of_manufacture": 2018, "raw": ["016257", "000213", "0", "2018/Feb/28 16:53", "Fonderie Sime S.p.A.", "Sime", "Format DGT HE", "25/15", "", "2009", "2018", "2", "2", "1", "2", "0", "", "", "2", "3", "2", "19.5", "19.5", "", "", "89.0", "80.4", "", "56.5", "", "2", "1", "", "104", "1", "2", "125", "8", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.8", "99.0", "", "", "", "", "97.3"]} -{"pcdb_id": 16258, "brand_name": "Sime", "model_name": "Format DGT HE", "model_qualifier": "35", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 56.2, "output_kw_max": 29.4, "final_year_of_manufacture": 2018, "raw": ["016258", "000213", "0", "2018/Feb/28 16:55", "Fonderie Sime S.p.A.", "Sime", "Format DGT HE", "35", "", "2009", "2018", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "29.4", "29.4", "", "", "88.5", "79.9", "", "56.2", "", "2", "", "", "104", "1", "2", "130", "8", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.5", "97.8", "", "", "", "", "96.0"]} -{"pcdb_id": 16259, "brand_name": "Sime", "model_name": "Format DGT HE", "model_qualifier": "35", "winter_efficiency_pct": 89.5, "summer_efficiency_pct": 80.9, "comparative_hot_water_efficiency_pct": 56.9, "output_kw_max": 29.4, "final_year_of_manufacture": 2018, "raw": ["016259", "000213", "0", "2018/Feb/28 16:56", "Fonderie Sime S.p.A.", "Sime", "Format DGT HE", "35", "", "2009", "2018", "2", "2", "1", "2", "0", "", "", "2", "3", "2", "29.4", "29.4", "", "", "89.5", "80.9", "", "56.9", "", "2", "1", "", "104", "1", "2", "130", "8", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.4", "99.9", "", "", "", "", "98.1"]} -{"pcdb_id": 16260, "brand_name": "Sime", "model_name": "Format DGT HE", "model_qualifier": "30", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 56.0, "output_kw_max": 24.6, "final_year_of_manufacture": 2018, "raw": ["016260", "000213", "0", "2018/Feb/28 16:53", "Fonderie Sime S.p.A.", "Sime", "Format DGT HE", "30", "", "2009", "2018", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "24.6", "24.6", "", "", "88.2", "79.6", "", "56.0", "", "2", "", "", "104", "1", "2", "125", "8", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.5", "97.2", "", "", "", "", "95.6"]} -{"pcdb_id": 16261, "brand_name": "Sime", "model_name": "Format DGT HE", "model_qualifier": "30", "winter_efficiency_pct": 89.3, "summer_efficiency_pct": 80.7, "comparative_hot_water_efficiency_pct": 56.7, "output_kw_max": 24.6, "final_year_of_manufacture": 2018, "raw": ["016261", "000213", "0", "2018/Feb/28 16:54", "Fonderie Sime S.p.A.", "Sime", "Format DGT HE", "30", "", "2009", "2018", "2", "2", "1", "2", "0", "", "", "2", "3", "2", "24.6", "24.6", "", "", "89.3", "80.7", "", "56.7", "", "2", "1", "", "104", "1", "2", "125", "8", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.4", "99.4", "", "", "", "", "97.7"]} -{"pcdb_id": 16262, "brand_name": "Sime", "model_name": "Format DGT HE", "model_qualifier": "25", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 55.8, "output_kw_max": 19.5, "final_year_of_manufacture": 2018, "raw": ["016262", "000213", "0", "2018/Feb/28 16:50", "Fonderie Sime S.p.A.", "Sime", "Format DGT HE", "25", "", "2009", "2018", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "19.5", "19.5", "", "", "88.0", "79.4", "", "55.8", "", "2", "", "", "104", "1", "2", "125", "8", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "96.9", "", "", "", "", "95.1"]} -{"pcdb_id": 16263, "brand_name": "Sime", "model_name": "Format DGT HE", "model_qualifier": "25", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.4, "comparative_hot_water_efficiency_pct": 56.5, "output_kw_max": 19.5, "final_year_of_manufacture": 2018, "raw": ["016263", "000213", "0", "2018/Feb/28 16:51", "Fonderie Sime S.p.A.", "Sime", "Format DGT HE", "25", "", "2009", "2018", "2", "2", "1", "2", "0", "", "", "2", "3", "2", "19.5", "19.5", "", "", "89.0", "80.4", "", "56.5", "", "2", "1", "", "104", "1", "2", "125", "8", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.8", "99.0", "", "", "", "", "97.3"]} -{"pcdb_id": 16272, "brand_name": "Fer", "model_name": "tech", "model_qualifier": "18ov", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 17.7, "final_year_of_manufacture": 2017, "raw": ["016272", "000097", "0", "2017/Aug/21 13:35", "Ferroli", "Fer", "tech", "18ov", "41-267-38", "2009", "2017", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "17.7", "17.7", "", "", "88.7", "79.7", "", "58.2", "", "2", "", "", "102", "1", "2", "50", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.6", "98.3", "", "", "", "", "96.5"]} -{"pcdb_id": 16273, "brand_name": "Fer", "model_name": "tech", "model_qualifier": "18ov", "winter_efficiency_pct": 89.7, "summer_efficiency_pct": 80.7, "comparative_hot_water_efficiency_pct": 58.9, "output_kw_max": 17.7, "final_year_of_manufacture": 2017, "raw": ["016273", "000097", "0", "2017/Aug/21 13:44", "Ferroli", "Fer", "tech", "18ov", "", "2009", "2017", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "17.7", "17.7", "", "", "89.7", "80.7", "", "58.9", "", "2", "1", "", "102", "1", "2", "50", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.5", "100.5", "", "", "", "", "98.6"]} -{"pcdb_id": 16274, "brand_name": "Fer", "model_name": "tech", "model_qualifier": "25ov", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 24.6, "final_year_of_manufacture": 2017, "raw": ["016274", "000097", "0", "2017/Aug/21 13:36", "Ferroli", "Fer", "tech", "25ov", "41-267-39", "2009", "2017", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24.6", "24.6", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "50", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.6", "97.6", "", "", "", "", "95.9"]} -{"pcdb_id": 16275, "brand_name": "Fer", "model_name": "tech", "model_qualifier": "25ov", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 80.4, "comparative_hot_water_efficiency_pct": 58.7, "output_kw_max": 24.6, "final_year_of_manufacture": 2017, "raw": ["016275", "000097", "0", "2017/Aug/21 13:43", "Ferroli", "Fer", "tech", "25ov", "", "2009", "2017", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "24.6", "24.6", "", "", "89.4", "80.4", "", "58.7", "", "2", "1", "", "102", "1", "2", "50", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.5", "99.7", "", "", "", "", "98.0"]} -{"pcdb_id": 16276, "brand_name": "Fer", "model_name": "tech", "model_qualifier": "31C", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 56.1, "output_kw_max": 24.6, "final_year_of_manufacture": 2017, "raw": ["016276", "000097", "0", "2017/Aug/21 13:36", "Ferroli", "Fer", "tech", "31C", "47-267-51", "2009", "2017", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.6", "24.6", "", "", "88.4", "79.8", "", "56.1", "", "2", "", "", "104", "1", "2", "130", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "", "", "0005", "", "", "", "", "", "", "", "", "88.6", "97.6", "", "", "", "", "95.9"]} -{"pcdb_id": 16277, "brand_name": "Fer", "model_name": "tech", "model_qualifier": "31C", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 56.8, "output_kw_max": 24.6, "final_year_of_manufacture": 2017, "raw": ["016277", "000097", "0", "2017/Aug/21 13:38", "Ferroli", "Fer", "tech", "31C", "", "2009", "2017", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24.6", "24.6", "", "", "89.4", "80.8", "", "56.8", "", "2", "1", "", "104", "1", "2", "130", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "", "", "0005", "", "", "", "", "", "", "", "", "90.5", "99.7", "", "", "", "", "98.0"]} -{"pcdb_id": 16278, "brand_name": "Fer", "model_name": "tech", "model_qualifier": "38C", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 56.3, "output_kw_max": 30.2, "final_year_of_manufacture": 2017, "raw": ["016278", "000097", "0", "2017/Aug/21 13:36", "Ferroli", "Fer", "tech", "38C", "47-267-52", "2009", "2017", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "30.2", "30.2", "", "", "88.7", "80.1", "", "56.3", "", "2", "", "", "104", "1", "2", "140", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "", "", "0005", "", "", "", "", "", "", "", "", "88.7", "98.3", "", "", "", "", "96.5"]} -{"pcdb_id": 16279, "brand_name": "Fer", "model_name": "tech", "model_qualifier": "38C", "winter_efficiency_pct": 89.7, "summer_efficiency_pct": 81.1, "comparative_hot_water_efficiency_pct": 57.1, "output_kw_max": 30.2, "final_year_of_manufacture": 2017, "raw": ["016279", "000097", "0", "2017/Aug/21 13:38", "Ferroli", "Fer", "tech", "38C", "", "2009", "2017", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "30.2", "30.2", "", "", "89.7", "81.1", "", "57.1", "", "2", "1", "", "104", "1", "2", "140", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "", "", "0005", "", "", "", "", "", "", "", "", "90.7", "100.5", "", "", "", "", "98.6"]} -{"pcdb_id": 16281, "brand_name": "Remeha", "model_name": "Avanta", "model_qualifier": "12 V", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 12.0, "final_year_of_manufacture": null, "raw": ["016281", "000005", "0", "2012/Apr/11 14:49", "Remeha", "Remeha", "Avanta", "12 V", "41-288-09", "2009", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "12", "12", "", "", "88.1", "79.1", "", "57.8", "", "2", "", "", "102", "1", "2", "50", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.1", "97.0", "", "", "", "", "95.3"]} -{"pcdb_id": 16282, "brand_name": "Remeha", "model_name": "Avanta", "model_qualifier": "28 ECO", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 62.4, "output_kw_max": 21.6, "final_year_of_manufacture": null, "raw": ["016282", "000006", "0", "2009/Dec/08 15:34", "Remeha", "Remeha", "Avanta", "28 ECO", "47-288-02", "2009", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "21.6", "21.6", "", "", "88.5", "79.9", "", "62.4", "", "2", "", "", "104", "1", "2", "115", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "3", "1", "", "0005", "", "", "", "", "", "", "", "", "88.6", "97.9", "", "", "", "", "96.2"]} -{"pcdb_id": 16283, "brand_name": "Remeha", "model_name": "Avanta", "model_qualifier": "30 V", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 29.4, "final_year_of_manufacture": null, "raw": ["016283", "000005", "0", "2012/Apr/11 14:49", "Remeha", "Remeha", "Avanta", "30 V", "41-288-14", "2009", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "29.4", "29.4", "", "", "88.2", "79.2", "", "57.9", "", "2", "", "", "102", "1", "2", "115", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.5", "97.1", "", "", "", "", "95.5"]} -{"pcdb_id": 16284, "brand_name": "Remeha", "model_name": "Avanta Plus", "model_qualifier": "18S", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 18.0, "final_year_of_manufacture": null, "raw": ["016284", "000005", "0", "2012/Apr/11 14:49", "Remeha", "Remeha", "Avanta Plus", "18S", "41-288-11", "2008", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18", "18", "", "", "88.1", "79.1", "", "57.8", "", "2", "", "", "102", "1", "2", "115", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.1", "97.0", "", "", "", "", "95.3"]} -{"pcdb_id": 16285, "brand_name": "Remeha", "model_name": "Avanta", "model_qualifier": "15v", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 15.0, "final_year_of_manufacture": null, "raw": ["016285", "000005", "0", "2012/Apr/11 14:49", "Remeha", "Remeha", "Avanta", "15v", "41-288-13", "2009", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "15", "15", "", "", "88.2", "79.2", "", "57.8", "", "2", "", "", "102", "1", "2", "50", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.4", "97.0", "", "", "", "", "95.4"]} -{"pcdb_id": 16286, "brand_name": "Remeha", "model_name": "Avanta Plus", "model_qualifier": "24 C", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 55.9, "output_kw_max": 20.0, "final_year_of_manufacture": null, "raw": ["016286", "000005", "0", "2012/Apr/11 14:49", "Remeha", "Remeha", "Avanta Plus", "24 C", "47-288-01", "2008", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "20.0", "20.0", "", "", "88.1", "79.5", "", "55.9", "", "2", "", "", "104", "1", "2", "115", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "0", "", "0005", "", "", "", "", "", "", "", "", "88.1", "97.0", "", "", "", "", "95.3"]} -{"pcdb_id": 16287, "brand_name": "Remeha", "model_name": "Avanta Plus", "model_qualifier": "30 S", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 29.4, "final_year_of_manufacture": null, "raw": ["016287", "000005", "0", "2012/Apr/11 14:49", "Remeha", "Remeha", "Avanta Plus", "30 S", "41-288-12", "2008", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "29.4", "29.4", "", "", "88.2", "79.2", "", "57.9", "", "2", "", "", "102", "1", "2", "150", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.5", "97.1", "", "", "", "", "95.5"]} -{"pcdb_id": 16289, "brand_name": "Remeha", "model_name": "Avanta", "model_qualifier": "24 V", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 24.7, "final_year_of_manufacture": null, "raw": ["016289", "000005", "0", "2012/Apr/11 14:49", "Remeha", "Remeha", "Avanta", "24 V", "41-288-10", "2008", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24.7", "24.7", "", "", "88.2", "79.2", "", "57.8", "", "2", "", "", "102", "1", "2", "50", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.2", "97.1", "", "", "", "", "95.4"]} -{"pcdb_id": 16291, "brand_name": "Ferroli", "model_name": "DOMIcondens", "model_qualifier": "F24", "winter_efficiency_pct": 86.4, "summer_efficiency_pct": 77.8, "comparative_hot_water_efficiency_pct": 54.7, "output_kw_max": 24.1, "final_year_of_manufacture": 2017, "raw": ["016291", "000097", "0", "2017/Aug/21 13:37", "Ferroli", "Ferroli", "DOMIcondens", "F24", "", "2009", "2017", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.1", "24.1", "", "", "86.4", "77.8", "", "54.7", "", "2", "", "", "104", "1", "2", "135", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "86.9", "93.3", "", "", "", "", "92.1"]} -{"pcdb_id": 16292, "brand_name": "Ferroli", "model_name": "DOMIcondens", "model_qualifier": "F24", "winter_efficiency_pct": 87.4, "summer_efficiency_pct": 78.8, "comparative_hot_water_efficiency_pct": 55.4, "output_kw_max": 24.1, "final_year_of_manufacture": 2017, "raw": ["016292", "000097", "0", "2017/Aug/21 13:38", "Ferroli", "Ferroli", "DOMIcondens", "F24", "", "2009", "2017", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24.1", "24.1", "", "", "87.4", "78.8", "", "55.4", "", "2", "1", "", "104", "1", "2", "135", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.9", "95.3", "", "", "", "", "94.1"]} -{"pcdb_id": 16294, "brand_name": "Keston", "model_name": "Q37", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 33.6, "final_year_of_manufacture": null, "raw": ["016294", "000022", "0", "2012/Mar/27 10:12", "Keston Boilers", "Keston", "Q37", "", "", "2010", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "33.6", "33.6", "", "", "88.6", "79.6", "", "58.1", "", "2", "", "", "102", "1", "2", "198", "4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.4", "98.1", "", "", "", "", "96.3"]} -{"pcdb_id": 16295, "brand_name": "Keston", "model_name": "Q37P", "model_qualifier": "", "winter_efficiency_pct": 89.6, "summer_efficiency_pct": 80.6, "comparative_hot_water_efficiency_pct": 58.9, "output_kw_max": 33.6, "final_year_of_manufacture": null, "raw": ["016295", "000022", "0", "2012/Mar/27 10:12", "Keston Boilers", "Keston", "Q37P", "", "", "2010", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "33.6", "33.6", "", "", "89.6", "80.6", "", "58.9", "", "2", "1", "", "102", "1", "2", "198", "4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.4", "100.3", "", "", "", "", "98.4"]} -{"pcdb_id": 16296, "brand_name": "ARCA", "model_name": "PIXELfast 25 FC", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 56.2, "output_kw_max": 24.4, "final_year_of_manufacture": null, "raw": ["016296", "000261", "0", "2010/Jan/28 12:31", "ARCA", "ARCA", "PIXELfast 25 FC", "", "", "2008", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.4", "24.4", "", "", "88.5", "79.9", "", "56.2", "", "2", "", "", "104", "1", "2", "150", "5", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "97.9", "", "", "", "", "96.1"]} -{"pcdb_id": 16297, "brand_name": "ARCA", "model_name": "PIXELfast 25FCR", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 24.4, "final_year_of_manufacture": null, "raw": ["016297", "000261", "0", "2012/Mar/27 10:12", "ARCA", "ARCA", "PIXELfast 25FCR", "", "", "2008", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24.4", "24.4", "", "", "88.5", "79.5", "", "58.0", "", "2", "", "", "102", "1", "2", "150", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "97.9", "", "", "", "", "96.1"]} -{"pcdb_id": 16298, "brand_name": "ARCA", "model_name": "PIXELfast 31 FC", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 56.2, "output_kw_max": 30.2, "final_year_of_manufacture": null, "raw": ["016298", "000261", "0", "2010/Jan/28 12:31", "ARCA", "ARCA", "PIXELfast 31 FC", "", "", "2008", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "30.2", "30.2", "", "", "88.5", "79.9", "", "56.2", "", "2", "", "", "104", "1", "2", "150", "5", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "97.9", "", "", "", "", "96.1"]} -{"pcdb_id": 16299, "brand_name": "ARCA", "model_name": "PIXELfast 31 FCR", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 30.2, "final_year_of_manufacture": null, "raw": ["016299", "000261", "0", "2012/Mar/27 10:12", "ARCA", "ARCA", "PIXELfast 31 FCR", "", "", "2008", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "30.2", "30.2", "", "", "88.5", "79.5", "", "58.0", "", "2", "", "", "102", "1", "2", "150", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "97.9", "", "", "", "", "96.1"]} -{"pcdb_id": 16300, "brand_name": "ARCA", "model_name": "PIXELfast 26 FCX", "model_qualifier": "", "winter_efficiency_pct": 87.4, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 56.4, "output_kw_max": 25.4, "final_year_of_manufacture": null, "raw": ["016300", "000261", "0", "2012/Jul/03 16:27", "ARCA", "ARCA", "PIXELfast 26 FCX", "", "", "2007", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "25.4", "25.4", "", "", "87.4", "80.2", "", "56.4", "", "2", "", "", "103", "1", "1", "150", "5", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "88.7", "98.6", "", "", "", "", "96.7"]} -{"pcdb_id": 16301, "brand_name": "ARCA", "model_name": "PIXELfast 26 FCXR", "model_qualifier": "", "winter_efficiency_pct": 87.4, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 25.4, "final_year_of_manufacture": null, "raw": ["016301", "000261", "0", "2012/Jul/03 16:27", "ARCA", "ARCA", "PIXELfast 26 FCXR", "", "", "2007", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "25.4", "25.4", "", "", "87.4", "79.8", "", "58.3", "", "2", "", "", "101", "1", "1", "150", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "88.7", "98.6", "", "", "", "", "96.7"]} -{"pcdb_id": 16302, "brand_name": "ARCA", "model_name": "PIXELfast B 26 FCX", "model_qualifier": "", "winter_efficiency_pct": 87.4, "summer_efficiency_pct": 81.5, "comparative_hot_water_efficiency_pct": 78.7, "output_kw_max": 25.4, "final_year_of_manufacture": null, "raw": ["016302", "000261", "0", "2024/Jan/31 10:17", "ARCA", "ARCA", "PIXELfast B 26 FCX", "", "", "2007", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "25.4", "25.4", "", "", "87.4", "81.5", "", "78.7", "", "2", "", "", "105", "1", "1", "150", "5", "0", "1", "", "50", "0", "11", "2", "60", "62", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "88.7", "98.6", "", "", "", "", "96.7"]} -{"pcdb_id": 16303, "brand_name": "ARCA", "model_name": "PIXELfast 120/25 FC", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 56.2, "output_kw_max": 24.4, "final_year_of_manufacture": null, "raw": ["016303", "000261", "0", "2010/Jan/28 12:30", "ARCA", "ARCA", "PIXELfast 120/25 FC", "", "", "2009", "current", "1", "1", "1", "2", "0", "", "", "2", "2", "2", "24.4", "24.4", "", "", "88.5", "79.9", "", "56.2", "", "2", "", "", "104", "1", "2", "150", "5", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "97.9", "", "", "", "", "96.1"]} -{"pcdb_id": 16304, "brand_name": "ARCA", "model_name": "PIXELfast 120/26 FCX", "model_qualifier": "", "winter_efficiency_pct": 87.4, "summer_efficiency_pct": 81.5, "comparative_hot_water_efficiency_pct": 81.5, "output_kw_max": 25.4, "final_year_of_manufacture": null, "raw": ["016304", "000261", "0", "2024/Jan/31 10:17", "ARCA", "ARCA", "PIXELfast 120/26 FCX", "", "", "2009", "current", "1", "1", "1", "2", "0", "", "", "2", "2", "2", "25.4", "25.4", "", "", "87.4", "81.5", "", "81.5", "", "2", "", "", "105", "1", "1", "150", "5", "0", "1", "", "100", "0", "18", "2", "60", "86", "0", "", "", "", "", "", "", "", "", "", "0", "0", "", "0003", "", "", "", "", "", "", "", "", "88.7", "98.6", "", "", "", "", "96.7"]} -{"pcdb_id": 16305, "brand_name": "ARCA", "model_name": "PIXELfast 120/31 FC", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 56.2, "output_kw_max": 30.2, "final_year_of_manufacture": null, "raw": ["016305", "000261", "0", "2010/Jan/28 12:30", "ARCA", "ARCA", "PIXELfast 120/31 FC", "", "", "2009", "current", "1", "1", "1", "2", "0", "", "", "2", "2", "2", "30.2", "30.2", "", "", "88.5", "79.9", "", "56.2", "", "2", "", "", "104", "1", "2", "150", "5", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "97.9", "", "", "", "", "96.1"]} -{"pcdb_id": 16306, "brand_name": "ARCA", "model_name": "PIXELfast 26 FCX Sun", "model_qualifier": "", "winter_efficiency_pct": 87.4, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 56.4, "output_kw_max": 25.4, "final_year_of_manufacture": null, "raw": ["016306", "000261", "0", "2012/Jul/03 16:28", "ARCA", "ARCA", "PIXELfast 26 FCX Sun", "", "", "2008", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "25.4", "25.4", "", "", "87.4", "80.2", "", "56.4", "", "2", "", "", "103", "1", "1", "150", "5", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "88.7", "98.6", "", "", "", "", "96.7"]} -{"pcdb_id": 16307, "brand_name": "ARCA", "model_name": "PIXELfast 31 FC Sun", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 56.2, "output_kw_max": 30.2, "final_year_of_manufacture": null, "raw": ["016307", "000261", "0", "2010/Jan/28 12:30", "ARCA", "ARCA", "PIXELfast 31 FC Sun", "", "", "2005", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "30.2", "30.2", "", "", "88.5", "79.9", "", "56.2", "", "2", "", "", "104", "1", "2", "150", "5", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "97.9", "", "", "", "", "96.1"]} -{"pcdb_id": 16308, "brand_name": "ARCA", "model_name": "PIXELfast 25 FC Sun", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 56.2, "output_kw_max": 24.4, "final_year_of_manufacture": null, "raw": ["016308", "000261", "0", "2010/Jan/28 12:29", "ARCA", "ARCA", "PIXELfast 25 FC Sun", "", "", "2008", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.4", "24.4", "", "", "88.5", "79.9", "", "56.2", "", "2", "", "", "104", "1", "2", "150", "5", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "97.9", "", "", "", "", "96.1"]} -{"pcdb_id": 16311, "brand_name": "Termet", "model_name": "Ecocondens Plus", "model_qualifier": "25", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 22.9, "final_year_of_manufacture": null, "raw": ["016311", "000262", "0", "2012/Mar/27 10:12", "Termet", "Termet", "Ecocondens Plus", "25", "", "2009", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "22.9", "22.9", "", "", "88.1", "79.1", "", "57.8", "", "2", "", "", "102", "1", "2", "200", "8", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "97.2", "", "", "", "", "95.4"]} -{"pcdb_id": 16312, "brand_name": "Termet", "model_name": "Ecocondens Plus", "model_qualifier": "25 combi", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 55.9, "output_kw_max": 22.9, "final_year_of_manufacture": null, "raw": ["016312", "000262", "0", "2010/Feb/08 15:42", "Termet", "Termet", "Ecocondens Plus", "25 combi", "", "2009", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "22.9", "22.9", "", "", "88.1", "79.5", "", "55.9", "", "2", "", "", "104", "1", "2", "200", "8", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "97.2", "", "", "", "", "95.4"]} -{"pcdb_id": 16313, "brand_name": "Termet", "model_name": "Ecocondens Plus", "model_qualifier": "30", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 28.8, "final_year_of_manufacture": null, "raw": ["016313", "000262", "0", "2012/Mar/27 10:12", "Termet", "Termet", "Ecocondens Plus", "30", "", "2009", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "28.8", "28.8", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "200", "8", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "96.9", "", "", "", "", "95.1"]} -{"pcdb_id": 16314, "brand_name": "Termet", "model_name": "Ecocondens Plus", "model_qualifier": "30 combi", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 55.8, "output_kw_max": 28.8, "final_year_of_manufacture": null, "raw": ["016314", "000262", "0", "2013/Feb/21 14:42", "Termet", "Termet", "Ecocondens Plus", "30 combi", "", "2009", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28.8", "28.8", "", "", "88.0", "79.4", "", "55.8", "", "2", "", "", "104", "1", "2", "200", "8", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "96.9", "", "", "", "", "95.1"]} -{"pcdb_id": 16315, "brand_name": "Termet", "model_name": "Ecocondens Plus", "model_qualifier": "50", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 45.3, "final_year_of_manufacture": null, "raw": ["016315", "000262", "0", "2012/Mar/27 10:12", "Termet", "Termet", "Ecocondens Plus", "50", "", "2009", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "45.3", "45.3", "", "", "88.1", "79.1", "", "57.7", "", "2", "", "", "102", "1", "2", "200", "8", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "97.0", "", "", "", "", "95.3"]} -{"pcdb_id": 16316, "brand_name": "Termet", "model_name": "Windsor Plus", "model_qualifier": "25", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 22.9, "final_year_of_manufacture": null, "raw": ["016316", "000262", "0", "2012/Mar/27 10:12", "Termet", "Termet", "Windsor Plus", "25", "", "2009", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "22.9", "22.9", "", "", "88.1", "79.1", "", "57.8", "", "2", "", "", "102", "1", "2", "200", "8", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "97.2", "", "", "", "", "95.4"]} -{"pcdb_id": 16317, "brand_name": "Termet", "model_name": "Windsor Plus", "model_qualifier": "25 combi", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 55.9, "output_kw_max": 22.9, "final_year_of_manufacture": null, "raw": ["016317", "000262", "0", "2010/Feb/08 15:42", "Termet", "Termet", "Windsor Plus", "25 combi", "", "2009", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "22.9", "22.9", "", "", "88.1", "79.5", "", "55.9", "", "2", "", "", "104", "1", "2", "200", "8", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "97.2", "", "", "", "", "95.4"]} -{"pcdb_id": 16318, "brand_name": "Termet", "model_name": "Windsor Plus", "model_qualifier": "30", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 28.8, "final_year_of_manufacture": null, "raw": ["016318", "000262", "0", "2012/Mar/27 10:12", "Termet", "Termet", "Windsor Plus", "30", "", "2009", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "28.8", "28.8", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "200", "8", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "96.9", "", "", "", "", "95.1"]} -{"pcdb_id": 16319, "brand_name": "Termet", "model_name": "Windsor Plus", "model_qualifier": "30 combi", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 55.8, "output_kw_max": 28.8, "final_year_of_manufacture": null, "raw": ["016319", "000262", "0", "2010/Feb/08 15:42", "Termet", "Termet", "Windsor Plus", "30 combi", "", "2009", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28.8", "28.8", "", "", "88.0", "79.4", "", "55.8", "", "2", "", "", "104", "1", "2", "200", "8", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "96.9", "", "", "", "", "95.1"]} -{"pcdb_id": 16320, "brand_name": "Termet", "model_name": "Windsor Plus", "model_qualifier": "50", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 45.3, "final_year_of_manufacture": null, "raw": ["016320", "000262", "0", "2012/Mar/27 10:12", "Termet", "Termet", "Windsor Plus", "50", "", "2009", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "45.3", "45.3", "", "", "88.1", "79.1", "", "57.7", "", "2", "", "", "102", "1", "2", "200", "8", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "97.0", "", "", "", "", "95.3"]} -{"pcdb_id": 16321, "brand_name": "Glow-worm", "model_name": "Ultracom 2 12sxi", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 12.0, "final_year_of_manufacture": null, "raw": ["016321", "000207", "0", "2012/Mar/27 10:12", "Vaillant Group UK", "Glow-worm", "Ultracom 2 12sxi", "", "G.C.No.41-019-12", "2010", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "12.0", "12.0", "", "", "88.8", "79.8", "", "58.3", "", "2", "", "", "102", "1", "2", "151", "6", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0085", "", "", "", "", "", "", "", "", "88.5", "98.7", "", "", "", "", "96.7"]} -{"pcdb_id": 16323, "brand_name": "Glow-worm", "model_name": "Ultracom 2 18sxi", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 18.2, "final_year_of_manufacture": null, "raw": ["016323", "000207", "0", "2012/Mar/27 10:12", "Vaillant Group UK", "Glow-worm", "Ultracom 2 18sxi", "", "G.C.No.41-019-13", "2010", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18.2", "18.2", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "151", "6", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0085", "", "", "", "", "", "", "", "", "88.5", "97.7", "", "", "", "", "95.9"]} -{"pcdb_id": 16324, "brand_name": "Glow-worm", "model_name": "Ultracom 2 18sxi", "model_qualifier": "", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 80.4, "comparative_hot_water_efficiency_pct": 58.8, "output_kw_max": 18.2, "final_year_of_manufacture": null, "raw": ["016324", "000207", "0", "2012/Mar/27 10:12", "Vaillant Group UK", "Glow-worm", "Ultracom 2 18sxi", "", "", "2010", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "18.2", "18.2", "", "", "89.4", "80.4", "", "58.8", "", "2", "1", "", "102", "1", "2", "151", "6", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.4", "99.8", "", "", "", "", "98.1"]} -{"pcdb_id": 16325, "brand_name": "Glow-worm", "model_name": "Ultracom 2 24cxi", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 86.8, "comparative_hot_water_efficiency_pct": 73.9, "output_kw_max": 18.2, "final_year_of_manufacture": null, "raw": ["016325", "000207", "0", "2012/Jul/20 11:52", "Vaillant Group UK", "Glow-worm", "Ultracom 2 24cxi", "", "G.C.No.41-019-10", "2010", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "18.2", "18.2", "", "", "88.4", "86.8", "", "73.9", "", "2", "", "", "104", "1", "2", "151", "6", "0", "", "", "0", "0", "", "", "", "", "1", "7.127", "0.111", "0.0002", "1.02333", "", "", "", "", "", "", "", "", "0085", "", "", "", "", "", "", "", "", "88.5", "97.7", "", "", "", "", "95.9"]} -{"pcdb_id": 16326, "brand_name": "Glow-worm", "model_name": "Ultracom 2 24cxi", "model_qualifier": "", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 56.8, "output_kw_max": 18.2, "final_year_of_manufacture": null, "raw": ["016326", "000207", "0", "2010/May/27 08:28", "Vaillant Group UK", "Glow-worm", "Ultracom 2 24cxi", "", "", "2010", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "18.2", "18.2", "", "", "89.4", "80.8", "", "56.8", "", "2", "1", "", "104", "1", "2", "151", "6", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.4", "99.8", "", "", "", "", "98.1"]} -{"pcdb_id": 16327, "brand_name": "Glow-worm", "model_name": "Ultracom 2 30cxi", "model_qualifier": "", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 86.8, "comparative_hot_water_efficiency_pct": 73.6, "output_kw_max": 24.6, "final_year_of_manufacture": null, "raw": ["016327", "000207", "0", "2012/Jul/20 11:55", "Vaillant Group UK", "Glow-worm", "Ultracom 2 30cxi", "", "G.C.No.47-019-11", "2010", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.6", "24.6", "", "", "88.7", "86.8", "", "73.6", "", "2", "", "", "104", "1", "2", "151", "6", "0", "", "", "0", "0", "", "", "", "", "1", "7.152", "0.11", "0.0007", "1.04421", "", "", "", "", "", "", "", "", "0085", "", "", "", "", "", "", "", "", "88.5", "98.4", "", "", "", "", "96.5"]} -{"pcdb_id": 16328, "brand_name": "Glow-worm", "model_name": "Ultracom 2 30cxi", "model_qualifier": "", "winter_efficiency_pct": 89.7, "summer_efficiency_pct": 81.1, "comparative_hot_water_efficiency_pct": 57.0, "output_kw_max": 24.6, "final_year_of_manufacture": null, "raw": ["016328", "000207", "0", "2010/May/26 07:53", "Vaillant Group UK", "Glow-worm", "Ultracom 2 30cxi", "", "G.C.No.47-019-11", "2010", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24.6", "24.6", "", "", "89.7", "81.1", "", "57.0", "", "2", "1", "", "104", "1", "2", "151", "6", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.4", "100.6", "", "", "", "", "98.6"]} -{"pcdb_id": 16331, "brand_name": "Lamborghini Caloreclima", "model_name": "Extrema", "model_qualifier": "30 C", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 56.2, "output_kw_max": 24.6, "final_year_of_manufacture": 2017, "raw": ["016331", "000097", "0", "2017/Aug/21 13:37", "Ferroli", "Lamborghini Caloreclima", "Extrema", "30 C", "", "2009", "2017", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.6", "24.6", "", "", "88.5", "79.9", "", "56.2", "", "2", "", "", "104", "1", "2", "130", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "98.2", "", "", "", "", "96.3"]} -{"pcdb_id": 16332, "brand_name": "Lamborghini Caloreclima", "model_name": "Extrema", "model_qualifier": "30 C", "winter_efficiency_pct": 89.6, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 56.9, "output_kw_max": 24.6, "final_year_of_manufacture": 2017, "raw": ["016332", "000097", "0", "2017/Aug/21 13:39", "Ferroli", "Lamborghini Caloreclima", "Extrema", "30 C", "", "2009", "2017", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24.6", "24.6", "", "", "89.6", "81.0", "", "56.9", "", "2", "1", "", "104", "1", "2", "130", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "", "", "0005", "", "", "", "", "", "", "", "", "89.9", "100.4", "", "", "", "", "98.4"]} -{"pcdb_id": 16333, "brand_name": "Lamborghini Caloreclima", "model_name": "Extrema", "model_qualifier": "38 C", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 56.2, "output_kw_max": 31.4, "final_year_of_manufacture": 2017, "raw": ["016333", "000097", "0", "2017/Aug/21 13:37", "Ferroli", "Lamborghini Caloreclima", "Extrema", "38 C", "", "2009", "2017", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "31.4", "31.4", "", "", "88.5", "79.9", "", "56.2", "", "2", "", "", "104", "1", "2", "150", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "98.2", "", "", "", "", "96.3"]} -{"pcdb_id": 16335, "brand_name": "Lamborghini Caloreclima", "model_name": "Extrema", "model_qualifier": "38 C", "winter_efficiency_pct": 89.6, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 56.9, "output_kw_max": 31.4, "final_year_of_manufacture": 2017, "raw": ["016335", "000097", "0", "2017/Aug/21 13:41", "Ferroli", "Lamborghini Caloreclima", "Extrema", "38 C", "", "2009", "2017", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "31.4", "31.4", "", "", "89.6", "81.0", "", "56.9", "", "2", "1", "", "104", "1", "2", "150", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "", "", "0005", "", "", "", "", "", "", "", "", "89.9", "100.4", "", "", "", "", "98.4"]} -{"pcdb_id": 16348, "brand_name": "ATAG", "model_name": "A325C", "model_qualifier": "X", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 56.6, "output_kw_max": 28.8, "final_year_of_manufacture": null, "raw": ["016348", "000227", "0", "2013/Oct/23 12:58", "ATAG Verwarming Nederland BV", "ATAG", "A325C", "X", "", "2010", "current", "1", "3", "1", "2", "0", "", "", "2", "3", "2", "28.8", "28.8", "", "", "89.1", "80.5", "", "56.6", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.8", "98.8", "", "", "", "", "97.1"]} -{"pcdb_id": 16349, "brand_name": "ATAG", "model_name": "A320S", "model_qualifier": "X", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 28.8, "final_year_of_manufacture": null, "raw": ["016349", "000227", "0", "2013/Oct/23 12:58", "ATAG Verwarming Nederland BV", "ATAG", "A320S", "X", "", "2010", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "28.8", "28.8", "", "", "89.1", "80.1", "", "58.5", "", "2", "", "", "102", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.8", "98.8", "", "", "", "", "97.1"]} -{"pcdb_id": 16353, "brand_name": "ATAG", "model_name": "A325EC", "model_qualifier": "X", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 85.2, "output_kw_max": 28.8, "final_year_of_manufacture": null, "raw": ["016353", "000227", "3", "2021/Nov/29 20:19", "ATAG Verwarming Nederland BV", "ATAG", "A325EC", "X", "", "2010", "current", "1", "2", "1", "2", "1", "313", "060023", "2", "3", "2", "28.8", "28.8", "", "", "89.1", "87.3", "", "85.2", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "", "0", "", "", "", "", "1", "6.18", "0.178", "0.0008", "0.13684", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.8", "98.8", "", "", "", "", "97.1"]} -{"pcdb_id": 16356, "brand_name": "Unical", "model_name": "Alkon R 18 HE", "model_qualifier": "", "winter_efficiency_pct": 87.7, "summer_efficiency_pct": 78.7, "comparative_hot_water_efficiency_pct": 57.5, "output_kw_max": 17.7, "final_year_of_manufacture": null, "raw": ["016356", "000263", "0", "2012/Mar/27 10:12", "Unical AG", "Unical", "Alkon R 18 HE", "", "", "2010", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "17.7", "17.7", "", "", "87.7", "78.7", "", "57.5", "", "2", "", "", "102", "1", "2", "132", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.6", "95.9", "", "", "", "", "94.5"]} -{"pcdb_id": 16357, "brand_name": "Unical", "model_name": "Alkon C 18 HE", "model_qualifier": "", "winter_efficiency_pct": 87.7, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 55.6, "output_kw_max": 17.7, "final_year_of_manufacture": null, "raw": ["016357", "000263", "0", "2010/May/27 11:09", "Unical AG", "Unical", "Alkon C 18 HE", "", "", "2010", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "17.7", "17.7", "", "", "87.7", "79.1", "", "55.6", "", "2", "", "", "104", "1", "2", "132", "5", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.6", "95.9", "", "", "", "", "94.5"]} -{"pcdb_id": 16358, "brand_name": "Unical", "model_name": "Alkon C 24 HE", "model_qualifier": "", "winter_efficiency_pct": 87.8, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 55.7, "output_kw_max": 23.3, "final_year_of_manufacture": null, "raw": ["016358", "000263", "0", "2010/May/27 11:09", "Unical AG", "Unical", "Alkon C 24 HE", "", "", "2010", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "23.3", "23.3", "", "", "87.8", "79.2", "", "55.7", "", "2", "", "", "104", "1", "2", "132", "5", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "96.3", "", "", "", "", "94.7"]} -{"pcdb_id": 16359, "brand_name": "Unical", "model_name": "Alkon R 24 HE", "model_qualifier": "", "winter_efficiency_pct": 87.8, "summer_efficiency_pct": 78.8, "comparative_hot_water_efficiency_pct": 57.6, "output_kw_max": 23.3, "final_year_of_manufacture": null, "raw": ["016359", "000263", "0", "2012/Mar/27 10:12", "Unical AG", "Unical", "Alkon R 24 HE", "", "", "2010", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "23.3", "23.3", "", "", "87.8", "78.8", "", "57.6", "", "2", "", "", "102", "1", "2", "132", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "96.3", "", "", "", "", "94.7"]} -{"pcdb_id": 16360, "brand_name": "Unical", "model_name": "Alkon 28 SR HE", "model_qualifier": "", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 78.9, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 27.3, "final_year_of_manufacture": null, "raw": ["016360", "000263", "0", "2012/Mar/27 10:12", "Unical AG", "Unical", "Alkon 28 SR HE", "", "", "2010", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "27.3", "27.3", "", "", "87.9", "78.9", "", "57.7", "", "2", "", "", "102", "1", "2", "130", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "96.7", "", "", "", "", "95.0"]} -{"pcdb_id": 16361, "brand_name": "Unical", "model_name": "Alkon 28 SC HE", "model_qualifier": "", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 55.8, "output_kw_max": 27.3, "final_year_of_manufacture": null, "raw": ["016361", "000263", "0", "2010/May/27 11:11", "Unical AG", "Unical", "Alkon 28 SC HE", "", "", "2010", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "27.3", "27.3", "", "", "87.9", "79.3", "", "55.8", "", "2", "", "", "104", "1", "2", "130", "5", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "96.7", "", "", "", "", "95.0"]} -{"pcdb_id": 16362, "brand_name": "Unical", "model_name": "Alkon Slim 28 HE", "model_qualifier": "", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 56.0, "output_kw_max": 27.5, "final_year_of_manufacture": null, "raw": ["016362", "000263", "0", "2010/May/27 11:08", "Unical AG", "Unical", "Alkon Slim 28 HE", "", "", "2010", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "27.5", "27.5", "", "", "88.2", "79.6", "", "56.0", "", "2", "", "", "104", "1", "2", "163", "5", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.4", "97.1", "", "", "", "", "95.5"]} -{"pcdb_id": 16363, "brand_name": "Unical", "model_name": "Alkon Slim 35 HE", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 55.9, "output_kw_max": 33.3, "final_year_of_manufacture": null, "raw": ["016363", "000263", "0", "2010/May/27 11:08", "Unical AG", "Unical", "Alkon Slim 35 HE", "", "", "2010", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "33.3", "33.3", "", "", "88.1", "79.5", "", "55.9", "", "2", "", "", "104", "1", "2", "163", "5", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "96.9", "", "", "", "", "95.2"]} -{"pcdb_id": 16364, "brand_name": "Glow-worm", "model_name": "Ultracom 2 30sxi", "model_qualifier": "", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 30.0, "final_year_of_manufacture": null, "raw": ["016364", "000207", "0", "2013/Jan/30 14:46", "Vaillant Group UK", "Glow-worm", "Ultracom 2 30sxi", "", "G.C.No.41-019-14", "2010", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "30.0", "30.0", "", "", "88.7", "79.7", "", "58.2", "", "2", "", "", "102", "1", "2", "151", "6", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0085", "", "", "", "", "", "", "", "", "88.6", "98.4", "", "", "", "", "96.5"]} -{"pcdb_id": 16365, "brand_name": "Glow-worm", "model_name": "Ultracom 2 30sxi", "model_qualifier": "", "winter_efficiency_pct": 89.7, "summer_efficiency_pct": 80.7, "comparative_hot_water_efficiency_pct": 59.0, "output_kw_max": 30.0, "final_year_of_manufacture": null, "raw": ["016365", "000207", "0", "2013/Jan/30 14:46", "Vaillant Group UK", "Glow-worm", "Ultracom 2 30sxi", "", "G.C.No.41-019-14", "2010", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "30.0", "30.0", "", "", "89.7", "80.7", "", "59.0", "", "2", "1", "", "102", "1", "2", "151", "6", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.5", "100.6", "", "", "", "", "98.7"]} -{"pcdb_id": 16366, "brand_name": "Glow-worm", "model_name": "Ultracom 2 35cxi", "model_qualifier": "", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 86.9, "comparative_hot_water_efficiency_pct": 72.2, "output_kw_max": 30.0, "final_year_of_manufacture": null, "raw": ["016366", "000207", "0", "2013/Jan/30 14:47", "Vaillant Group UK", "Glow-worm", "Ultracom 2 35cxi", "", "G.C.No.47-019-12", "2010", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "30.0", "30.0", "", "", "88.7", "86.9", "", "72.2", "", "2", "", "", "104", "1", "2", "151", "6", "0", "", "", "0", "0", "", "", "", "", "1", "7.291", "0.109", "0.0006", "1.18145", "", "", "", "", "", "", "", "", "0085", "", "", "", "", "", "", "", "", "88.6", "98.4", "", "", "", "", "96.5"]} -{"pcdb_id": 16367, "brand_name": "Glow-worm", "model_name": "Ultracom 2 35cxi", "model_qualifier": "", "winter_efficiency_pct": 89.7, "summer_efficiency_pct": 81.1, "comparative_hot_water_efficiency_pct": 57.1, "output_kw_max": 30.0, "final_year_of_manufacture": null, "raw": ["016367", "000207", "0", "2013/Jan/30 14:47", "Vaillant Group UK", "Glow-worm", "Ultracom 2 35cxi", "", "G.C.No.47-019-12", "2010", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "30.0", "30.0", "", "", "89.7", "81.1", "", "57.1", "", "2", "1", "", "104", "1", "2", "151", "6", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.5", "100.6", "", "", "", "", "98.7"]} -{"pcdb_id": 16368, "brand_name": "Intergas", "model_name": "Compact HRE 30 OV", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 26.6, "final_year_of_manufacture": null, "raw": ["016368", "000256", "0", "2012/Mar/27 10:12", "Intergas Heating Ltd", "Intergas", "Compact HRE 30 OV", "", "", "2009", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "26.6", "26.6", "", "", "88.5", "79.5", "", "58.0", "", "2", "", "", "102", "1", "2", "130", "1.9", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.9", "97.6", "", "", "", "", "95.9"]} -{"pcdb_id": 16369, "brand_name": "Intergas", "model_name": "Compact HRE 24 OV", "model_qualifier": "", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 23.1, "final_year_of_manufacture": null, "raw": ["016369", "000256", "0", "2012/Mar/27 10:12", "Intergas Heating Ltd", "Intergas", "Compact HRE 24 OV", "", "", "2009", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "23.1", "23.1", "", "", "88.2", "79.2", "", "57.8", "", "2", "", "", "102", "1", "2", "130", "1.9", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "97.2", "", "", "", "", "95.5"]} -{"pcdb_id": 16371, "brand_name": "Intergas", "model_name": "Compact HRE 18 OV", "model_qualifier": "", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 18.2, "final_year_of_manufacture": null, "raw": ["016371", "000256", "0", "2014/Nov/24 13:35", "Intergas Heating Ltd", "Intergas", "Compact HRE 18 OV", "", "", "2009", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18.2", "18.2", "", "", "88.2", "79.2", "", "57.9", "", "2", "", "", "102", "1", "2", "130", "1.9", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "97.4", "", "", "", "", "95.6"]} -{"pcdb_id": 16372, "brand_name": "Unical", "model_name": "Alkon 35 SC HE", "model_qualifier": "", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 55.7, "output_kw_max": 33.8, "final_year_of_manufacture": null, "raw": ["016372", "000263", "0", "2010/May/27 11:08", "Unical", "Unical", "Alkon 35 SC HE", "", "", "2010", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "33.8", "33.8", "", "", "87.9", "79.3", "", "55.7", "", "2", "", "", "104", "1", "2", "130", "5", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.1", "96.4", "", "", "", "", "94.8"]} -{"pcdb_id": 16373, "brand_name": "Unical", "model_name": "Alkon 35 SR HE", "model_qualifier": "", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 78.9, "comparative_hot_water_efficiency_pct": 57.6, "output_kw_max": 33.8, "final_year_of_manufacture": null, "raw": ["016373", "000263", "0", "2012/Mar/27 10:12", "Unical", "Unical", "Alkon 35 SR HE", "", "", "2010", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "33.8", "33.8", "", "", "87.9", "78.9", "", "57.6", "", "2", "", "", "102", "1", "2", "130", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.1", "96.4", "", "", "", "", "94.8"]} -{"pcdb_id": 16374, "brand_name": "Ideal", "model_name": "Independent", "model_qualifier": "C24", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 69.3, "output_kw_max": 24.2, "final_year_of_manufacture": 2016, "raw": ["016374", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "Independent", "C24", "47-348-68", "2010", "2016", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "88.4", "87.3", "", "69.3", "", "2", "", "", "104", "1", "2", "146", "1", "0", "", "", "0", "0", "", "", "", "", "1", "7.5959", "0.1755", "0.008", "1.46665", "", "", "", "", "", "1", "1", "0", "0035", "", "", "", "", "", "", "", "", "89.8", "96.9", "", "", "", "", "95.6"]} -{"pcdb_id": 16375, "brand_name": "Ideal", "model_name": "Independent", "model_qualifier": "C30", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 69.8, "output_kw_max": 24.2, "final_year_of_manufacture": 2016, "raw": ["016375", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "Independent", "C30", "47-348-69", "2010", "2016", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "88.4", "87.3", "", "69.8", "", "2", "", "", "104", "1", "2", "152", "1", "0", "", "", "0", "0", "", "", "", "", "1", "7.548", "0.1749", "0.0099", "1.41408", "", "", "", "", "", "1", "1", "0", "0035", "", "", "", "", "", "", "", "", "90.0", "96.9", "", "", "", "", "95.6"]} -{"pcdb_id": 16376, "brand_name": "Ideal", "model_name": "Independent", "model_qualifier": "C35", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 71.0, "output_kw_max": 24.2, "final_year_of_manufacture": 2016, "raw": ["016376", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "Independent", "C35", "47-348-70", "2010", "2016", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "88.3", "87.3", "", "71.0", "", "2", "", "", "104", "1", "2", "177", "1", "0", "", "", "0", "0", "", "", "", "", "1", "7.4216", "0.171", "0.0087", "1.2937", "", "", "", "", "", "1", "1", "0", "0035", "", "", "", "", "", "", "", "", "89.8", "96.9", "", "", "", "", "95.5"]} -{"pcdb_id": 16378, "brand_name": "Sime", "model_name": "Format DGT HE", "model_qualifier": "20 System", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 19.5, "final_year_of_manufacture": 2018, "raw": ["016378", "000213", "0", "2018/Feb/26 17:09", "Fonderie Sime S.p.A.", "Sime", "Format DGT HE", "20 System", "", "2009", "2018", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "19.5", "19.5", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "125", "8", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "96.9", "", "", "", "", "95.1"]} -{"pcdb_id": 16379, "brand_name": "Sime", "model_name": "Format DGT HE", "model_qualifier": "20 System", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 19.5, "final_year_of_manufacture": 2018, "raw": ["016379", "000213", "0", "2018/Feb/28 16:49", "Fonderie Sime S.p.A.", "Sime", "Format DGT HE", "20 System", "", "2009", "2018", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "19.5", "19.5", "", "", "89.0", "80.0", "", "58.4", "", "2", "1", "", "102", "1", "2", "125", "8", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.8", "99.0", "", "", "", "", "97.3"]} -{"pcdb_id": 16380, "brand_name": "Navien", "model_name": "NCN-21K", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 56.4, "output_kw_max": 19.3, "final_year_of_manufacture": null, "raw": ["016380", "000265", "0", "2011/May/27 12:32", "KD Navien", "Navien", "NCN-21K", "", "", "2010", "current", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "19.3", "19.3", "", "", "88.8", "80.2", "", "56.4", "", "2", "", "", "104", "1", "2", "130", "6.81", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.5", "98.6", "", "", "", "", "96.7"]} -{"pcdb_id": 16381, "brand_name": "Navien", "model_name": "NCN-21K", "model_qualifier": "", "winter_efficiency_pct": 89.8, "summer_efficiency_pct": 81.2, "comparative_hot_water_efficiency_pct": 57.1, "output_kw_max": 19.3, "final_year_of_manufacture": null, "raw": ["016381", "000265", "0", "2011/May/27 12:32", "KD Navien", "Navien", "NCN-21K", "", "", "2010", "current", "2", "2", "1", "2", "0", "", "", "2", "3", "2", "19.3", "19.3", "", "", "89.8", "81.2", "", "57.1", "", "2", "1", "", "104", "1", "2", "130", "6.81", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.4", "100.8", "", "", "", "", "98.8"]} -{"pcdb_id": 16382, "brand_name": "Navien", "model_name": "NCN-25K", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 56.1, "output_kw_max": 23.1, "final_year_of_manufacture": null, "raw": ["016382", "000265", "0", "2010/Jul/30 10:37", "KD Navien", "Navien", "NCN-25K", "", "", "2010", "current", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "23.1", "23.1", "", "", "88.4", "79.8", "", "56.1", "", "2", "", "", "104", "1", "2", "130", "6.81", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.4", "97.7", "", "", "", "", "95.9"]} -{"pcdb_id": 16383, "brand_name": "Navien", "model_name": "NCN-25K", "model_qualifier": "", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 56.8, "output_kw_max": 23.1, "final_year_of_manufacture": null, "raw": ["016383", "000265", "0", "2010/Jul/30 10:37", "KD Navien", "Navien", "NCN-25K", "", "", "2010", "current", "2", "2", "1", "2", "0", "", "", "2", "3", "2", "23.1", "23.1", "", "", "89.4", "80.8", "", "56.8", "", "2", "1", "", "104", "1", "2", "130", "6.81", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.4", "99.8", "", "", "", "", "98.0"]} -{"pcdb_id": 16384, "brand_name": "Navien", "model_name": "NCN-32K", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 56.2, "output_kw_max": 29.5, "final_year_of_manufacture": null, "raw": ["016384", "000265", "0", "2010/Jul/30 10:37", "KD Navien", "Navien", "NCN-32K", "", "", "2010", "current", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "29.5", "29.5", "", "", "88.5", "79.9", "", "56.2", "", "2", "", "", "104", "1", "2", "130", "6.81", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.7", "97.7", "", "", "", "", "96.0"]} -{"pcdb_id": 16385, "brand_name": "Navien", "model_name": "NCN-32K", "model_qualifier": "", "winter_efficiency_pct": 89.5, "summer_efficiency_pct": 80.9, "comparative_hot_water_efficiency_pct": 56.9, "output_kw_max": 29.5, "final_year_of_manufacture": null, "raw": ["016385", "000265", "0", "2010/Aug/23 16:09", "KD Navien", "Navien", "NCN-32K", "", "", "2010", "current", "2", "2", "1", "2", "0", "", "", "2", "3", "2", "29.5", "29.5", "", "", "89.5", "80.9", "", "56.9", "", "2", "1", "", "104", "1", "2", "130", "6.81", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.6", "99.8", "", "", "", "", "98.1"]} -{"pcdb_id": 16386, "brand_name": "Navien", "model_name": "NCN-37K", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 56.1, "output_kw_max": 34.2, "final_year_of_manufacture": null, "raw": ["016386", "000265", "0", "2010/Jul/30 10:38", "KD Navien", "Navien", "NCN-37K", "", "", "2010", "current", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "34.2", "34.2", "", "", "88.3", "79.7", "", "56.1", "", "2", "", "", "104", "1", "2", "130", "6.81", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "97.5", "", "", "", "", "95.7"]} -{"pcdb_id": 16387, "brand_name": "Navien", "model_name": "NCN-37K", "model_qualifier": "", "winter_efficiency_pct": 89.3, "summer_efficiency_pct": 80.7, "comparative_hot_water_efficiency_pct": 56.8, "output_kw_max": 34.2, "final_year_of_manufacture": null, "raw": ["016387", "000265", "0", "2016/Jan/06 17:02", "KD Navien", "Navien", "NCN-37K", "", "", "2010", "current", "2", "2", "1", "2", "0", "", "", "2", "3", "2", "34.2", "34.2", "", "", "89.3", "80.7", "", "56.8", "", "2", "1", "", "104", "1", "2", "130", "6.81", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.3", "99.7", "", "", "", "", "97.9"]} -{"pcdb_id": 16388, "brand_name": "Ideal", "model_name": "Esprit 2", "model_qualifier": "24", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 62.1, "output_kw_max": 23.4, "final_year_of_manufacture": 2011, "raw": ["016388", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "Esprit 2", "24", "47-348-71", "2010", "2011", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "23.4", "23.4", "", "", "88.1", "79.5", "", "62.1", "", "2", "", "", "104", "1", "2", "148", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "0", "0005", "", "", "", "", "", "", "", "", "87.9", "97.1", "", "", "", "", "95.4"]} -{"pcdb_id": 16389, "brand_name": "Ideal", "model_name": "Esprit 2", "model_qualifier": "30", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 62.1, "output_kw_max": 23.4, "final_year_of_manufacture": 2011, "raw": ["016389", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "Esprit 2", "30", "47-348-72", "2010", "2011", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "23.4", "23.4", "", "", "88.1", "79.5", "", "62.1", "", "2", "", "", "104", "1", "2", "148", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "0", "0005", "", "", "", "", "", "", "", "", "87.9", "97.1", "", "", "", "", "95.4"]} -{"pcdb_id": 16390, "brand_name": "Ideal", "model_name": "Esprit 2", "model_qualifier": "35", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 62.1, "output_kw_max": 23.4, "final_year_of_manufacture": 2011, "raw": ["016390", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "Esprit 2", "35", "47-348-73", "2010", "2011", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "23.4", "23.4", "", "", "88.1", "79.5", "", "62.1", "", "2", "", "", "104", "1", "2", "152", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "0", "0005", "", "", "", "", "", "", "", "", "87.9", "97.1", "", "", "", "", "95.4"]} -{"pcdb_id": 16393, "brand_name": "Ideal", "model_name": "Logic System", "model_qualifier": "30", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 30.3, "final_year_of_manufacture": 2016, "raw": ["016393", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "Logic System", "30", "41-750-27", "2010", "2016", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "30.3", "30.3", "", "", "88.9", "79.9", "", "58.3", "", "2", "", "", "102", "1", "2", "152", "1", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "89.8", "98.2", "", "", "", "", "96.6"]} -{"pcdb_id": 16394, "brand_name": "Ideal", "model_name": "Logic System", "model_qualifier": "24", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 24.2, "final_year_of_manufacture": 2016, "raw": ["016394", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "Logic System", "24", "41-750-26", "2010", "2016", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "88.8", "79.8", "", "58.3", "", "2", "", "", "102", "1", "2", "146", "1", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "89.6", "98.0", "", "", "", "", "96.4"]} -{"pcdb_id": 16395, "brand_name": "Ideal", "model_name": "Logic System", "model_qualifier": "18", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 18.0, "final_year_of_manufacture": 2016, "raw": ["016395", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "Logic System", "18", "41-750-25", "2010", "2016", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18", "18", "", "", "88.5", "79.5", "", "58.1", "", "2", "", "", "102", "1", "2", "131", "1", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "89.6", "97.4", "", "", "", "", "95.9"]} -{"pcdb_id": 16396, "brand_name": "Ideal", "model_name": "Logic System", "model_qualifier": "15", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 15.0, "final_year_of_manufacture": 2016, "raw": ["016396", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "Logic System", "15", "41-750-24", "2010", "2016", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "15", "15", "", "", "88.6", "79.6", "", "58.2", "", "2", "", "", "102", "1", "2", "126", "1", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "89.7", "97.7", "", "", "", "", "96.2"]} -{"pcdb_id": 16397, "brand_name": "Ideal", "model_name": "Logic Heat", "model_qualifier": "30", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 30.3, "final_year_of_manufacture": 2016, "raw": ["016397", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "Logic Heat", "30", "41-409-96", "2010", "2016", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "30.3", "30.3", "", "", "88.9", "79.9", "", "58.3", "", "2", "", "", "102", "1", "2", "48", "1", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "89.8", "98.2", "", "", "", "", "96.6"]} -{"pcdb_id": 16398, "brand_name": "Ideal", "model_name": "Logic Heat", "model_qualifier": "24", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 24.2, "final_year_of_manufacture": 2016, "raw": ["016398", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "Logic Heat", "24", "41-409-95", "2010", "2016", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "88.8", "79.8", "", "58.3", "", "2", "", "", "102", "1", "2", "46", "1", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "89.6", "98.0", "", "", "", "", "96.4"]} -{"pcdb_id": 16399, "brand_name": "Ideal", "model_name": "Logic Heat", "model_qualifier": "18", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 18.0, "final_year_of_manufacture": 2016, "raw": ["016399", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "Logic Heat", "18", "41-409-94", "2010", "2016", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18", "18", "", "", "88.5", "79.5", "", "58.1", "", "2", "", "", "102", "1", "2", "31", "1", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "89.6", "97.4", "", "", "", "", "95.9"]} -{"pcdb_id": 16400, "brand_name": "Ideal", "model_name": "Logic Heat", "model_qualifier": "15", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 15.0, "final_year_of_manufacture": 2016, "raw": ["016400", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "Logic Heat", "15", "41-409-93", "2010", "2016", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "15", "15", "", "", "88.6", "79.6", "", "58.2", "", "2", "", "", "102", "1", "2", "26", "1", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "89.7", "97.7", "", "", "", "", "96.2"]} -{"pcdb_id": 16401, "brand_name": "Ideal", "model_name": "Logic Heat", "model_qualifier": "12", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 12.0, "final_year_of_manufacture": 2016, "raw": ["016401", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "Logic Heat", "12", "41-399-99", "2010", "2016", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "12", "12", "", "", "88.7", "79.7", "", "58.2", "", "2", "", "", "102", "1", "2", "23", "1", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "89.9", "97.7", "", "", "", "", "96.2"]} -{"pcdb_id": 16402, "brand_name": "Ideal", "model_name": "Logic + System", "model_qualifier": "15", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 15.0, "final_year_of_manufacture": 2016, "raw": ["016402", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "Logic + System", "15", "41-750-29", "2010", "2016", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "15", "15", "", "", "88.6", "79.6", "", "58.2", "", "2", "", "", "102", "1", "2", "126", "1", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "89.7", "97.7", "", "", "", "", "96.2"]} -{"pcdb_id": 16403, "brand_name": "Ideal", "model_name": "Logic + System", "model_qualifier": "18", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 18.0, "final_year_of_manufacture": 2016, "raw": ["016403", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "Logic + System", "18", "41-750-30", "2010", "2016", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18", "18", "", "", "88.5", "79.5", "", "58.1", "", "2", "", "", "102", "1", "2", "131", "1", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "89.6", "97.4", "", "", "", "", "95.9"]} -{"pcdb_id": 16404, "brand_name": "Ideal", "model_name": "Logic + System", "model_qualifier": "24", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 24.2, "final_year_of_manufacture": 2016, "raw": ["016404", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "Logic + System", "24", "41-750-31", "2010", "2016", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "88.8", "79.8", "", "58.3", "", "2", "", "", "102", "1", "2", "146", "1", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "89.6", "98.0", "", "", "", "", "96.4"]} -{"pcdb_id": 16405, "brand_name": "Ideal", "model_name": "Logic + System", "model_qualifier": "30", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 30.3, "final_year_of_manufacture": 2016, "raw": ["016405", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "Logic + System", "30", "41-750-32", "2010", "2016", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "30.3", "30.3", "", "", "88.9", "79.9", "", "58.3", "", "2", "", "", "102", "1", "2", "152", "1", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "89.8", "98.2", "", "", "", "", "96.6"]} -{"pcdb_id": 16406, "brand_name": "Ideal", "model_name": "Logic + Heat", "model_qualifier": "30", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 30.3, "final_year_of_manufacture": 2016, "raw": ["016406", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "Logic + Heat", "30", "41-750-22", "2010", "2016", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "30.3", "30.3", "", "", "88.9", "79.9", "", "58.3", "", "2", "", "", "102", "1", "2", "48", "1", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "89.8", "98.2", "", "", "", "", "96.6"]} -{"pcdb_id": 16407, "brand_name": "Ideal", "model_name": "Logic + Heat", "model_qualifier": "24", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 24.2, "final_year_of_manufacture": 2016, "raw": ["016407", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "Logic + Heat", "24", "41-750-21", "2010", "2016", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "88.8", "79.8", "", "58.3", "", "2", "", "", "102", "1", "2", "46", "1", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "89.6", "98.0", "", "", "", "", "96.4"]} -{"pcdb_id": 16408, "brand_name": "Ideal", "model_name": "Logic + Heat", "model_qualifier": "18", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 18.0, "final_year_of_manufacture": 2016, "raw": ["016408", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "Logic + Heat", "18", "41-409-99", "2010", "2016", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18", "18", "", "", "88.5", "79.5", "", "58.1", "", "2", "", "", "102", "1", "2", "31", "1", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "89.6", "97.4", "", "", "", "", "95.9"]} -{"pcdb_id": 16409, "brand_name": "Ideal", "model_name": "Logic + Heat", "model_qualifier": "15", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 15.0, "final_year_of_manufacture": 2016, "raw": ["016409", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "Logic + Heat", "15", "41-409-98", "2010", "2016", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "15", "15", "", "", "88.6", "79.6", "", "58.2", "", "2", "", "", "102", "1", "2", "26", "1", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "89.7", "97.7", "", "", "", "", "96.2"]} -{"pcdb_id": 16410, "brand_name": "Ideal", "model_name": "Logic + Heat", "model_qualifier": "12", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 12.0, "final_year_of_manufacture": 2016, "raw": ["016410", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "Logic + Heat", "12", "41-409-97", "2010", "2016", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "12", "12", "", "", "88.7", "79.7", "", "58.2", "", "2", "", "", "102", "1", "2", "23", "1", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "89.9", "97.7", "", "", "", "", "96.2"]} -{"pcdb_id": 16411, "brand_name": "Keston", "model_name": "Keston", "model_qualifier": "30C", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 69.8, "output_kw_max": 24.2, "final_year_of_manufacture": null, "raw": ["016411", "000022", "0", "2011/Oct/28 08:08", "Keston Boilers", "Keston", "Keston", "30C", "47-930-03", "2010", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "88.4", "87.3", "", "69.8", "", "2", "", "", "104", "1", "2", "152", "1", "0", "", "", "0", "0", "", "", "", "", "1", "7.548", "0.1749", "0.0099", "1.41408", "", "", "", "", "", "1", "1", "0", "0005", "", "", "", "", "", "", "", "", "90.0", "96.9", "", "", "", "", "95.6"]} -{"pcdb_id": 16412, "brand_name": "Viessmann", "model_name": "Vitodens 200W WB2C", "model_qualifier": "35kW System", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 32.2, "final_year_of_manufacture": 2013, "raw": ["016412", "000033", "0", "2012/Mar/27 10:12", "Viessmann", "Viessmann", "Vitodens 200W WB2C", "35kW System", "41-819-17", "2009", "2013", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "32.2", "32.2", "", "", "88.5", "79.5", "", "58.1", "", "2", "", "", "102", "1", "2", "137", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.7", "97.8", "", "", "", "", "96.0"]} -{"pcdb_id": 16413, "brand_name": "Viessmann", "model_name": "Vitodens 200W WB2C", "model_qualifier": "35kW System", "winter_efficiency_pct": 89.5, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 58.8, "output_kw_max": 32.2, "final_year_of_manufacture": 2013, "raw": ["016413", "000033", "0", "2012/Mar/27 10:12", "Viessmann", "Viessmann", "Vitodens 200W WB2C", "35kW System", "", "2009", "2013", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "32.2", "32.2", "", "", "89.5", "80.5", "", "58.8", "", "2", "1", "", "102", "1", "2", "137", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.6", "99.9", "", "", "", "", "98.2"]} -{"pcdb_id": 16414, "brand_name": "Viessmann", "model_name": "Vitodens 200W WB2C", "model_qualifier": "35kW Combi", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 56.2, "output_kw_max": 32.2, "final_year_of_manufacture": 2013, "raw": ["016414", "000033", "0", "2012/Aug/28 09:59", "Viessmann", "Viessmann", "Vitodens 200W WB2C", "35kW Combi", "47-819-11", "2009", "2013", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "32.2", "32.2", "", "", "88.5", "79.9", "", "56.2", "", "2", "", "", "104", "1", "2", "137", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.7", "97.8", "", "", "", "", "96.0"]} -{"pcdb_id": 16415, "brand_name": "Viessmann", "model_name": "Vitodens 200W WB2C", "model_qualifier": "35kW Combi", "winter_efficiency_pct": 89.5, "summer_efficiency_pct": 80.9, "comparative_hot_water_efficiency_pct": 56.9, "output_kw_max": 32.2, "final_year_of_manufacture": 2013, "raw": ["016415", "000033", "0", "2010/Aug/17 09:24", "Viessmann", "Viessmann", "Vitodens 200W WB2C", "35kW Combi", "", "2009", "2013", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "32.2", "32.2", "", "", "89.5", "80.9", "", "56.9", "", "2", "1", "", "104", "1", "2", "137", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.6", "99.9", "", "", "", "", "98.2"]} -{"pcdb_id": 16416, "brand_name": "Viessmann", "model_name": "Vitodens 200W WB2C", "model_qualifier": "30kW System", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 27.8, "final_year_of_manufacture": 2013, "raw": ["016416", "000033", "0", "2012/Mar/27 10:12", "Viessmann", "Viessmann", "Vitodens 200W WB2C", "30kW System", "41-819-16", "2009", "2013", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "27.8", "27.8", "", "", "88.6", "79.6", "", "58.1", "", "2", "", "", "102", "1", "2", "100", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.2", "97.8", "", "", "", "", "96.1"]} -{"pcdb_id": 16417, "brand_name": "Viessmann", "model_name": "Vitodens 200W WB2C", "model_qualifier": "30kW System", "winter_efficiency_pct": 89.6, "summer_efficiency_pct": 80.6, "comparative_hot_water_efficiency_pct": 58.9, "output_kw_max": 27.8, "final_year_of_manufacture": 2013, "raw": ["016417", "000033", "0", "2012/Mar/27 10:12", "Viessmann", "Viessmann", "Vitodens 200W WB2C", "30kW System", "", "2009", "2013", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "27.8", "27.8", "", "", "89.6", "80.6", "", "58.9", "", "2", "1", "", "102", "1", "2", "100", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "91.2", "99.9", "", "", "", "", "98.3"]} -{"pcdb_id": 16418, "brand_name": "Viessmann", "model_name": "Vitodens 200W WB2C", "model_qualifier": "30kW Combi", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 56.2, "output_kw_max": 27.8, "final_year_of_manufacture": 2013, "raw": ["016418", "000033", "0", "2011/Jun/30 09:44", "Viessmann", "Viessmann", "Vitodens 200W WB2C", "30kW Combi", "47-819-10", "2009", "2013", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "27.8", "27.8", "", "", "88.6", "80.0", "", "56.2", "", "2", "", "", "104", "1", "2", "100", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.2", "97.8", "", "", "", "", "96.1"]} -{"pcdb_id": 16419, "brand_name": "Viessmann", "model_name": "Vitodens 200W WB2C", "model_qualifier": "30kW Combi", "winter_efficiency_pct": 89.6, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 57.0, "output_kw_max": 27.8, "final_year_of_manufacture": 2013, "raw": ["016419", "000033", "0", "2010/Aug/17 09:33", "Viessmann", "Viessmann", "Vitodens 200W WB2C", "30kW Combi", "", "2009", "2013", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "27.8", "27.8", "", "", "89.6", "81.0", "", "57.0", "", "2", "1", "", "104", "1", "2", "100", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "91.2", "99.9", "", "", "", "", "98.3"]} -{"pcdb_id": 16420, "brand_name": "Viessmann", "model_name": "Vitodens 200W WB2C", "model_qualifier": "26kW System", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 24.1, "final_year_of_manufacture": 2013, "raw": ["016420", "000033", "0", "2012/Mar/27 10:12", "Viessmann", "Viessmann", "Vitodens 200W WB2C", "26kW System", "41-819-15", "2009", "2013", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24.1", "24.1", "", "", "88.6", "79.6", "", "58.1", "", "2", "", "", "102", "1", "2", "95", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.9", "97.9", "", "", "", "", "96.2"]} -{"pcdb_id": 16421, "brand_name": "Viessmann", "model_name": "Vitodens 200W WB2C", "model_qualifier": "26kW System", "winter_efficiency_pct": 89.6, "summer_efficiency_pct": 80.6, "comparative_hot_water_efficiency_pct": 58.9, "output_kw_max": 24.1, "final_year_of_manufacture": 2013, "raw": ["016421", "000033", "0", "2012/Mar/27 10:12", "Viessmann", "Viessmann", "Vitodens 200W WB2C", "26kW System", "", "2009", "2013", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "24.1", "24.1", "", "", "89.6", "80.6", "", "58.9", "", "2", "1", "", "102", "1", "2", "95", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.9", "100.1", "", "", "", "", "98.4"]} -{"pcdb_id": 16422, "brand_name": "Viessmann", "model_name": "Vitodens 200W WB2C", "model_qualifier": "26kW Combi", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 56.3, "output_kw_max": 24.1, "final_year_of_manufacture": 2013, "raw": ["016422", "000033", "0", "2011/Jun/30 09:49", "Viessmann", "Viessmann", "Vitodens 200W WB2C", "26kW Combi", "47-819-09", "2009", "2013", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.1", "24.1", "", "", "88.6", "80.0", "", "56.3", "", "2", "", "", "104", "1", "2", "95", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.9", "97.9", "", "", "", "", "96.2"]} -{"pcdb_id": 16423, "brand_name": "Viessmann", "model_name": "Vitodens 200W WB2C", "model_qualifier": "26kW Combi", "winter_efficiency_pct": 89.6, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 57.0, "output_kw_max": 24.1, "final_year_of_manufacture": 2013, "raw": ["016423", "000033", "0", "2010/Aug/16 08:12", "Viessmann", "Viessmann", "Vitodens 200W WB2C", "26kW Combi", "", "2009", "2013", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24.1", "24.1", "", "", "89.6", "81.0", "", "57.0", "", "2", "1", "", "104", "1", "2", "95", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.9", "100.1", "", "", "", "", "98.4"]} -{"pcdb_id": 16424, "brand_name": "Viessmann", "model_name": "Vitodens 200W WB2C", "model_qualifier": "19kW System", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 17.5, "final_year_of_manufacture": 2013, "raw": ["016424", "000033", "0", "2012/Mar/27 10:12", "Viessmann", "Viessmann", "Vitodens 200W WB2C", "19kW System", "41-819-14", "2009", "2013", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "17.5", "17.5", "", "", "88.3", "79.3", "", "58.0", "", "2", "", "", "102", "1", "2", "85", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "97.7", "", "", "", "", "95.8"]} -{"pcdb_id": 16425, "brand_name": "Viessmann", "model_name": "Vitodens 200W WB2C", "model_qualifier": "19kW System", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 80.4, "comparative_hot_water_efficiency_pct": 58.7, "output_kw_max": 17.5, "final_year_of_manufacture": 2013, "raw": ["016425", "000033", "0", "2012/Mar/27 10:12", "Viessmann", "Viessmann", "Vitodens 200W WB2C", "19kW System", "", "2009", "2013", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "17.5", "17.5", "", "", "89.4", "80.4", "", "58.7", "", "2", "1", "", "102", "1", "2", "85", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.0", "99.8", "", "", "", "", "98.0"]} -{"pcdb_id": 16426, "brand_name": "Viessmann", "model_name": "Vitodens 222F FS2B", "model_qualifier": "19kW Combi with Store", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 52.8, "output_kw_max": 17.5, "final_year_of_manufacture": 2012, "raw": ["016426", "000033", "0", "2024/Jan/31 10:17", "Viessmann", "Viessmann", "Vitodens 222F FS2B", "19kW Combi with Store", "47-819-15", "2009", "2012", "1", "1", "1", "2", "0", "", "", "2", "2", "2", "17.5", "17.5", "", "", "88.3", "81.0", "", "52.8", "", "2", "", "", "106", "1", "2", "90", "", "2", "", "0", "100", "0", "50", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "97.7", "", "", "", "", "95.8"]} -{"pcdb_id": 16427, "brand_name": "Viessmann", "model_name": "Vitodens 222F FS2B", "model_qualifier": "19kW Combi with Store", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 82.1, "comparative_hot_water_efficiency_pct": 53.5, "output_kw_max": 17.5, "final_year_of_manufacture": 2012, "raw": ["016427", "000033", "0", "2024/Jan/31 10:17", "Viessmann", "Viessmann", "Vitodens 222F FS2B", "19kW Combi with Store", "", "2009", "2012", "2", "1", "1", "2", "0", "", "", "2", "2", "2", "17.5", "17.5", "", "", "89.4", "82.1", "", "53.5", "", "2", "1", "", "106", "1", "2", "90", "", "2", "", "0", "100", "0", "50", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.0", "99.8", "", "", "", "", "98.0"]} -{"pcdb_id": 16428, "brand_name": "Viessmann", "model_name": "Vitodens 222F FS2B", "model_qualifier": "26kW Combi with Store", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 81.3, "comparative_hot_water_efficiency_pct": 53.0, "output_kw_max": 24.1, "final_year_of_manufacture": 2012, "raw": ["016428", "000033", "0", "2024/Jan/31 10:17", "Viessmann", "Viessmann", "Vitodens 222F FS2B", "26kW Combi with Store", "47-819-16", "2009", "2012", "1", "1", "1", "2", "0", "", "", "2", "2", "2", "24.1", "24.1", "", "", "88.6", "81.3", "", "53.0", "", "2", "", "", "106", "1", "2", "105", "", "2", "", "0", "100", "0", "50", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.9", "97.9", "", "", "", "", "96.2"]} -{"pcdb_id": 16429, "brand_name": "Viessmann", "model_name": "Vitodens 222F FS2B", "model_qualifier": "26kW Combi with Store", "winter_efficiency_pct": 89.6, "summer_efficiency_pct": 82.3, "comparative_hot_water_efficiency_pct": 53.7, "output_kw_max": 24.1, "final_year_of_manufacture": 2012, "raw": ["016429", "000033", "0", "2024/Jan/31 10:17", "Viessmann", "Viessmann", "Vitodens 222F FS2B", "26kW Combi with Store", "", "2009", "2012", "2", "1", "1", "2", "0", "", "", "2", "2", "2", "24.1", "24.1", "", "", "89.6", "82.3", "", "53.7", "", "2", "1", "", "106", "1", "2", "105", "", "2", "", "0", "100", "0", "50", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.9", "100.1", "", "", "", "", "98.4"]} -{"pcdb_id": 16430, "brand_name": "Viessmann", "model_name": "Vitodens 222F FS2B", "model_qualifier": "35kW Combi with Store", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 81.2, "comparative_hot_water_efficiency_pct": 50.4, "output_kw_max": 32.2, "final_year_of_manufacture": 2012, "raw": ["016430", "000033", "0", "2024/Jan/31 10:17", "Viessmann", "Viessmann", "Vitodens 222F FS2B", "35kW Combi with Store", "47-819-17", "2009", "2012", "1", "1", "1", "2", "0", "", "", "2", "2", "2", "32.2", "32.2", "", "", "88.5", "81.2", "", "50.4", "", "2", "", "", "106", "1", "2", "138", "", "2", "", "0", "130", "0", "50", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.7", "97.8", "", "", "", "", "96.0"]} -{"pcdb_id": 16431, "brand_name": "Viessmann", "model_name": "Vitodens 222F FS2B", "model_qualifier": "35kW Combi with Store", "winter_efficiency_pct": 89.5, "summer_efficiency_pct": 82.2, "comparative_hot_water_efficiency_pct": 51.0, "output_kw_max": 32.2, "final_year_of_manufacture": 2012, "raw": ["016431", "000033", "0", "2024/Jan/31 10:17", "Viessmann", "Viessmann", "Vitodens 222F FS2B", "35kW Combi with Store", "", "2009", "2012", "2", "1", "1", "2", "0", "", "", "2", "2", "2", "32.2", "32.2", "", "", "89.5", "82.2", "", "51.0", "", "2", "1", "", "106", "1", "2", "138", "", "2", "", "0", "130", "0", "50", "", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "0", "", "0005", "", "", "", "", "", "", "", "", "90.6", "99.9", "", "", "", "", "98.2"]} -{"pcdb_id": 16432, "brand_name": "Viessmann", "model_name": "Vitodens 242F FB2B", "model_qualifier": "19kW Combi with Store", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 46.8, "output_kw_max": 17.5, "final_year_of_manufacture": 2012, "raw": ["016432", "000033", "0", "2024/Jan/31 10:17", "Viessmann", "Viessmann", "Vitodens 242F FB2B", "19kW Combi with Store", "47-819-18", "2009", "2012", "1", "1", "1", "2", "0", "", "", "2", "2", "2", "17.5", "17.5", "", "", "88.3", "81.0", "", "46.8", "", "2", "", "", "106", "1", "2", "90", "", "2", "", "0", "170", "0", "50", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "97.7", "", "", "", "", "95.8"]} -{"pcdb_id": 16433, "brand_name": "Viessmann", "model_name": "Vitodens 242F FB2B", "model_qualifier": "19kW Combi with Store", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 82.1, "comparative_hot_water_efficiency_pct": 47.4, "output_kw_max": 17.5, "final_year_of_manufacture": 2012, "raw": ["016433", "000033", "0", "2024/Jan/31 10:17", "Viessmann", "Viessmann", "Vitodens 242F FB2B", "19kW Combi with Store", "", "2009", "2012", "2", "1", "1", "2", "0", "", "", "2", "2", "2", "17.5", "17.5", "", "", "89.4", "82.1", "", "47.4", "", "2", "1", "", "106", "1", "2", "90", "", "2", "", "0", "170", "0", "50", "", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "0", "", "0005", "", "", "", "", "", "", "", "", "90.0", "99.8", "", "", "", "", "98.0"]} -{"pcdb_id": 16434, "brand_name": "Viessmann", "model_name": "Vitodens 242F FB2B", "model_qualifier": "26kW Combi with Store", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 81.3, "comparative_hot_water_efficiency_pct": 47.0, "output_kw_max": 24.1, "final_year_of_manufacture": 2012, "raw": ["016434", "000033", "0", "2024/Jan/31 10:17", "Viessmann", "Viessmann", "Vitodens 242F FB2B", "26kW Combi with Store", "47-819-19", "2009", "2012", "1", "1", "1", "2", "0", "", "", "2", "2", "2", "24.1", "24.1", "", "", "88.6", "81.3", "", "47.0", "", "2", "", "", "106", "1", "2", "105", "", "2", "", "0", "170", "0", "50", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.9", "97.9", "", "", "", "", "96.2"]} -{"pcdb_id": 16435, "brand_name": "Viessmann", "model_name": "Vitodens 242F FB2B", "model_qualifier": "26kW Combi with Store", "winter_efficiency_pct": 89.6, "summer_efficiency_pct": 82.3, "comparative_hot_water_efficiency_pct": 47.5, "output_kw_max": 24.1, "final_year_of_manufacture": 2012, "raw": ["016435", "000033", "0", "2024/Jan/31 10:17", "Viessmann", "Viessmann", "Vitodens 242F FB2B", "26kW Combi with Store", "", "2009", "2012", "2", "1", "1", "2", "0", "", "", "2", "2", "2", "24.1", "24.1", "", "", "89.6", "82.3", "", "47.5", "", "2", "1", "", "106", "1", "2", "", "", "2", "", "0", "170", "0", "50", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.9", "100.1", "", "", "", "", "98.4"]} -{"pcdb_id": 16437, "brand_name": "EHC", "model_name": "Eco Save 32K", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 56.2, "output_kw_max": 29.5, "final_year_of_manufacture": null, "raw": ["016437", "000266", "0", "2010/Jul/30 10:23", "KD Navien", "EHC", "Eco Save 32K", "", "", "2010", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "29.5", "29.5", "", "", "88.5", "79.9", "", "56.2", "", "2", "", "", "104", "1", "2", "135", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.7", "97.7", "", "", "", "", "96.0"]} -{"pcdb_id": 16438, "brand_name": "EHC", "model_name": "Eco Save 32k", "model_qualifier": "", "winter_efficiency_pct": 89.5, "summer_efficiency_pct": 80.9, "comparative_hot_water_efficiency_pct": 56.9, "output_kw_max": 29.5, "final_year_of_manufacture": null, "raw": ["016438", "000266", "0", "2010/Aug/24 08:19", "KD Navien", "EHC", "Eco Save 32k", "", "", "2010", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "29.5", "29.5", "", "", "89.5", "80.9", "", "56.9", "", "2", "1", "", "104", "1", "2", "135", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.6", "99.8", "", "", "", "", "98.1"]} -{"pcdb_id": 16439, "brand_name": "EHC", "model_name": "Eco Save 25K", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 56.1, "output_kw_max": 23.1, "final_year_of_manufacture": null, "raw": ["016439", "000266", "0", "2010/Jul/30 10:22", "KD Navien", "EHC", "Eco Save 25K", "", "", "2010", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "23.1", "23.1", "", "", "88.4", "79.8", "", "56.1", "", "2", "", "", "104", "1", "2", "130", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.4", "97.7", "", "", "", "", "95.9"]} -{"pcdb_id": 16440, "brand_name": "EHC", "model_name": "Eco Save 25K", "model_qualifier": "", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 56.8, "output_kw_max": 23.1, "final_year_of_manufacture": null, "raw": ["016440", "000266", "0", "2010/Jul/30 10:23", "KD Navien", "EHC", "Eco Save 25K", "", "", "2010", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "23.1", "23.1", "", "", "89.4", "80.8", "", "56.8", "", "2", "1", "", "104", "1", "2", "130", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.4", "99.8", "", "", "", "", "98.0"]} -{"pcdb_id": 16441, "brand_name": "EHC", "model_name": "Eco Save 21K", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 56.4, "output_kw_max": 19.3, "final_year_of_manufacture": null, "raw": ["016441", "000266", "0", "2011/May/25 09:28", "KD Navien", "EHC", "Eco Save 21K", "", "", "2010", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "19.3", "19.3", "", "", "88.8", "80.2", "", "56.4", "", "2", "", "", "104", "1", "2", "130", "6.81", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.5", "98.6", "", "", "", "", "96.7"]} -{"pcdb_id": 16442, "brand_name": "EHC", "model_name": "Eco Save 21K", "model_qualifier": "", "winter_efficiency_pct": 89.8, "summer_efficiency_pct": 81.2, "comparative_hot_water_efficiency_pct": 57.1, "output_kw_max": 19.3, "final_year_of_manufacture": null, "raw": ["016442", "000266", "0", "2011/May/25 09:28", "KD Navien", "EHC", "Eco Save 21K", "", "", "2010", "current", "2", "2", "1", "2", "0", "", "", "2", "3", "2", "19.3", "19.3", "", "", "89.8", "81.2", "", "57.1", "", "2", "1", "", "104", "1", "2", "130", "6.81", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.4", "100.8", "", "", "", "", "98.8"]} -{"pcdb_id": 16443, "brand_name": "EHC", "model_name": "Eco Save 37k", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 56.1, "output_kw_max": 34.2, "final_year_of_manufacture": null, "raw": ["016443", "000266", "0", "2010/Jul/30 10:24", "KD Navien", "EHC", "Eco Save 37k", "", "", "2010", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "34.2", "34.2", "", "", "88.3", "79.7", "", "56.1", "", "2", "", "", "104", "1", "2", "135", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "97.5", "", "", "", "", "95.7"]} -{"pcdb_id": 16444, "brand_name": "EHC", "model_name": "Eco Save 37k", "model_qualifier": "", "winter_efficiency_pct": 89.3, "summer_efficiency_pct": 80.7, "comparative_hot_water_efficiency_pct": 56.8, "output_kw_max": 34.2, "final_year_of_manufacture": null, "raw": ["016444", "000266", "0", "2010/Jul/30 10:24", "KD Navien", "EHC", "Eco Save 37k", "", "", "2010", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "34.2", "34.2", "", "", "89.3", "80.7", "", "56.8", "", "2", "1", "", "104", "1", "2", "135", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.3", "99.7", "", "", "", "", "97.9"]} -{"pcdb_id": 16445, "brand_name": "ARCA", "model_name": "PIXELfast B 31 FC", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 81.5, "comparative_hot_water_efficiency_pct": 39.3, "output_kw_max": 30.2, "final_year_of_manufacture": null, "raw": ["016445", "000261", "0", "2024/Jan/31 10:17", "ARCA", "ARCA", "PIXELfast B 31 FC", "", "", "2005", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "30.2", "30.2", "", "", "88.5", "81.5", "", "39.3", "", "2", "", "", "106", "1", "2", "150", "5", "2", "2", "0", "50", "0", "11", "2", "60", "62", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "97.9", "", "", "", "", "96.1"]} -{"pcdb_id": 16446, "brand_name": "ARCA", "model_name": "PIXELfast B 25 FC", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 81.5, "comparative_hot_water_efficiency_pct": 39.3, "output_kw_max": 24.4, "final_year_of_manufacture": null, "raw": ["016446", "000261", "0", "2024/Jan/31 10:17", "ARCA", "ARCA", "PIXELfast B 25 FC", "", "", "2005", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.4", "24.4", "", "", "88.5", "81.5", "", "39.3", "", "2", "", "", "106", "1", "2", "150", "50", "2", "2", "0", "50", "0", "11", "2", "60", "62", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "97.9", "", "", "", "", "96.1"]} -{"pcdb_id": 16447, "brand_name": "Main", "model_name": "12 HE A", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 11.82, "final_year_of_manufacture": 2015, "raw": ["016447", "000005", "0", "2015/Aug/06 13:11", "Baxi Heating UK", "Main", "12 HE A", "", "GC No. 41-467-16", "2010", "2015", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "11.82", "11.82", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "80", "1.07", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.6", "96.5", "", "", "", "", "95.0"]} -{"pcdb_id": 16448, "brand_name": "Main", "model_name": "15 HE A", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 15.24, "final_year_of_manufacture": 2015, "raw": ["016448", "000005", "0", "2015/Aug/06 13:12", "Baxi Heating UK", "Main", "15 HE A", "", "GC No. 41-467-17", "2010", "2015", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "15.24", "15.24", "", "", "88.3", "79.3", "", "57.9", "", "2", "", "", "102", "1", "2", "80", "2.49", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.3", "96.5", "", "", "", "", "95.3"]} -{"pcdb_id": 16449, "brand_name": "Main", "model_name": "18 HE A", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 17.81, "final_year_of_manufacture": 2015, "raw": ["016449", "000005", "0", "2015/Aug/06 13:12", "Baxi Heating UK", "Main", "18 HE A", "", "GC No. 41-467-18", "2010", "2015", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "17.81", "17.81", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "80", "2.49", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "96.8", "", "", "", "", "95.2"]} -{"pcdb_id": 16450, "brand_name": "Main", "model_name": "24 HE A", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 22.0, "final_year_of_manufacture": 2015, "raw": ["016450", "000005", "0", "2015/Aug/06 13:13", "Baxi Heating UK", "Main", "24 HE A", "", "GC No. 41-467-19", "2010", "2015", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "22.00", "22.00", "", "", "88.1", "79.1", "", "57.8", "", "2", "", "", "102", "1", "2", "80", "2.49", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.5", "96.5", "", "", "", "", "95.2"]} -{"pcdb_id": 16451, "brand_name": "Main", "model_name": "30 HE A", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 30.18, "final_year_of_manufacture": 2015, "raw": ["016451", "000005", "0", "2015/Aug/06 13:13", "Baxi Heating UK", "Main", "30 HE A", "", "GC No. 41-467-20", "2010", "2015", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "30.18", "30.18", "", "", "88.1", "79.1", "", "57.8", "", "2", "", "", "102", "1", "2", "80", "2.49", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.4", "96.4", "", "", "", "", "95.1"]} -{"pcdb_id": 16452, "brand_name": "Baxi", "model_name": "Solo", "model_qualifier": "12 HE A", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 11.82, "final_year_of_manufacture": 2015, "raw": ["016452", "000005", "0", "2015/Aug/06 11:56", "Baxi Heating UK", "Baxi", "Solo", "12 HE A", "GC No. 41-075-65", "2010", "2015", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "11.82", "11.82", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "80", "1.07", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.6", "96.5", "", "", "", "", "95.0"]} -{"pcdb_id": 16453, "brand_name": "Baxi", "model_name": "Solo", "model_qualifier": "15 HE A", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 15.24, "final_year_of_manufacture": 2015, "raw": ["016453", "000005", "0", "2015/Aug/06 11:56", "Baxi Heating UK", "Baxi", "Solo", "15 HE A", "GC No. 41-075-66", "2010", "2015", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "15.24", "15.24", "", "", "88.7", "79.7", "", "58.2", "", "2", "", "", "102", "1", "2", "80", "2.49", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.3", "97.7", "", "", "", "", "96.3"]} -{"pcdb_id": 16454, "brand_name": "Baxi", "model_name": "Solo", "model_qualifier": "18 HE A", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 17.81, "final_year_of_manufacture": 2015, "raw": ["016454", "000005", "0", "2015/Aug/06 11:57", "Baxi Heating UK", "Baxi", "Solo", "18 HE A", "GC No. 41-075-67", "2010", "2015", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "17.81", "17.81", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "80", "2.49", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "96.8", "", "", "", "", "95.2"]} -{"pcdb_id": 16455, "brand_name": "Baxi", "model_name": "Solo", "model_qualifier": "24 HE A", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 22.0, "final_year_of_manufacture": 2015, "raw": ["016455", "000005", "0", "2015/Aug/06 11:58", "Baxi Heating UK", "Baxi", "Solo", "24 HE A", "GC No. 41-075-68", "2010", "2015", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "22.0", "22.0", "", "", "88.1", "79.1", "", "57.8", "", "2", "", "", "102", "1", "2", "80", "2.49", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.5", "96.5", "", "", "", "", "95.2"]} -{"pcdb_id": 16456, "brand_name": "Baxi", "model_name": "Solo", "model_qualifier": "30 HE A", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 30.18, "final_year_of_manufacture": 2015, "raw": ["016456", "000005", "0", "2015/Aug/06 11:59", "Baxi Heating UK", "Baxi", "Solo", "30 HE A", "GC No. 41-075-69", "2010", "2015", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "30.18", "30.18", "", "", "88.1", "79.1", "", "57.8", "", "2", "", "", "102", "1", "2", "80", "2.49", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.4", "96.4", "", "", "", "", "95.1"]} -{"pcdb_id": 16457, "brand_name": "Nova Florida", "model_name": "Pictor Condensing KC 24 Line Tech", "model_qualifier": "", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 55.7, "output_kw_max": 23.1, "final_year_of_manufacture": null, "raw": ["016457", "000250", "0", "2010/Sep/14 11:43", "Fondital", "Nova Florida", "Pictor Condensing KC 24 Line Tech", "", "", "2006", "current", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "23.1", "23.1", "", "", "87.9", "79.3", "", "55.7", "", "2", "", "", "104", "1", "2", "155", "10", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "96.5", "", "", "", "", "94.9"]} -{"pcdb_id": 16458, "brand_name": "Nova Florida", "model_name": "Pictor Condensing KC 24 Line Tech", "model_qualifier": "", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 56.5, "output_kw_max": 23.1, "final_year_of_manufacture": null, "raw": ["016458", "000250", "0", "2010/Sep/14 11:43", "Fondital", "Nova Florida", "Pictor Condensing KC 24 Line Tech", "", "", "2006", "current", "2", "2", "1", "2", "0", "", "", "2", "3", "2", "23.1", "23.1", "", "", "88.9", "80.3", "", "56.5", "", "2", "1", "", "104", "1", "2", "155", "10", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.8", "98.7", "", "", "", "", "97.0"]} -{"pcdb_id": 16459, "brand_name": "Nova Florida", "model_name": "Pictor Condensing KC 28 Line Tech", "model_qualifier": "", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 55.7, "output_kw_max": 25.55, "final_year_of_manufacture": null, "raw": ["016459", "000250", "0", "2010/Sep/14 11:39", "Fondital", "Nova Florida", "Pictor Condensing KC 28 Line Tech", "", "", "2007", "current", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "25.55", "25.55", "", "", "87.9", "79.3", "", "55.7", "", "2", "", "", "104", "1", "2", "155", "10", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "96.5", "", "", "", "", "94.9"]} -{"pcdb_id": 16460, "brand_name": "Nova Florida", "model_name": "Pictor Condensing KC 28 Line Tech", "model_qualifier": "", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 56.4, "output_kw_max": 25.55, "final_year_of_manufacture": null, "raw": ["016460", "000250", "0", "2010/Sep/14 11:39", "Fondital", "Nova Florida", "Pictor Condensing KC 28 Line Tech", "", "", "2007", "current", "2", "2", "1", "2", "0", "", "", "2", "3", "2", "25.55", "25.55", "", "", "88.9", "80.3", "", "56.4", "", "2", "1", "", "104", "1", "2", "155", "10", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.8", "98.6", "", "", "", "", "97.0"]} -{"pcdb_id": 16461, "brand_name": "Nova Florida", "model_name": "Pictor Condensing KC 32 Line Tech", "model_qualifier": "", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 55.8, "output_kw_max": 30.6, "final_year_of_manufacture": null, "raw": ["016461", "000250", "0", "2010/Sep/14 11:40", "Fondital", "Nova Florida", "Pictor Condensing KC 32 Line Tech", "", "", "2006", "current", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "30.6", "30.6", "", "", "87.9", "79.3", "", "55.8", "", "2", "", "", "104", "1", "2", "155", "10", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "96.6", "", "", "", "", "94.9"]} -{"pcdb_id": 16462, "brand_name": "Nova Florida", "model_name": "Pictor Condensing KC 32 Line Tech", "model_qualifier": "", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 56.5, "output_kw_max": 30.6, "final_year_of_manufacture": null, "raw": ["016462", "000250", "0", "2010/Sep/14 11:40", "Fondital", "Nova Florida", "Pictor Condensing KC 32 Line Tech", "", "", "2006", "current", "2", "2", "1", "2", "0", "", "", "2", "3", "1", "30.6", "30.6", "", "", "88.9", "80.3", "", "56.5", "", "2", "1", "", "104", "1", "2", "155", "10", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.9", "98.7", "", "", "", "", "97.1"]} -{"pcdb_id": 16463, "brand_name": "Nova Florida", "model_name": "Pictor Condensing KR 24 Line Tech", "model_qualifier": "", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 78.9, "comparative_hot_water_efficiency_pct": 57.6, "output_kw_max": 23.1, "final_year_of_manufacture": null, "raw": ["016463", "000250", "0", "2012/Mar/27 10:12", "Fondital", "Nova Florida", "Pictor Condensing KR 24 Line Tech", "", "", "2006", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "23.1", "23.1", "", "", "87.9", "78.9", "", "57.6", "", "2", "", "", "102", "1", "2", "155", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "96.5", "", "", "", "", "94.9"]} -{"pcdb_id": 16464, "brand_name": "Nova Florida", "model_name": "Pictor Condensing KR 24 Line Tech", "model_qualifier": "", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 23.1, "final_year_of_manufacture": null, "raw": ["016464", "000250", "0", "2012/Mar/27 10:12", "Fondital", "Nova Florida", "Pictor Condensing KR 24 Line Tech", "", "", "2006", "current", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "23.1", "23.1", "", "", "88.9", "79.9", "", "58.3", "", "2", "1", "", "102", "1", "2", "155", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.8", "98.6", "", "", "", "", "97.0"]} -{"pcdb_id": 16465, "brand_name": "Nova Florida", "model_name": "Pictor Condensing KR 28 Line Tech", "model_qualifier": "", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 78.9, "comparative_hot_water_efficiency_pct": 57.6, "output_kw_max": 25.55, "final_year_of_manufacture": null, "raw": ["016465", "000250", "0", "2012/Mar/27 10:12", "Fondital", "Nova Florida", "Pictor Condensing KR 28 Line Tech", "", "", "2007", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "25.55", "25.55", "", "", "87.9", "78.9", "", "57.6", "", "2", "", "", "102", "1", "2", "155", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "96.5", "", "", "", "", "94.9"]} -{"pcdb_id": 16466, "brand_name": "Nova Florida", "model_name": "Pictor Condensing KR 28 Line Tech", "model_qualifier": "", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 25.55, "final_year_of_manufacture": null, "raw": ["016466", "000250", "0", "2012/Mar/27 10:12", "Fondital", "Nova Florida", "Pictor Condensing KR 28 Line Tech", "", "", "2008", "current", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "25.55", "25.55", "", "", "88.9", "79.9", "", "58.3", "", "2", "1", "", "102", "1", "2", "155", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.8", "98.6", "", "", "", "", "97.0"]} -{"pcdb_id": 16467, "brand_name": "Nova Florida", "model_name": "Pictor Condensing KR 32 Line Tech", "model_qualifier": "", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 78.9, "comparative_hot_water_efficiency_pct": 57.6, "output_kw_max": 30.6, "final_year_of_manufacture": null, "raw": ["016467", "000250", "0", "2012/Mar/27 10:12", "Fondital", "Nova Florida", "Pictor Condensing KR 32 Line Tech", "", "", "2006", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "30.6", "30.6", "", "", "87.9", "78.9", "", "57.6", "", "2", "", "", "102", "1", "2", "155", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "96.6", "", "", "", "", "94.9"]} -{"pcdb_id": 16468, "brand_name": "Nova Florida", "model_name": "Pictor Condensing KR 32 Line Tech", "model_qualifier": "", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 30.6, "final_year_of_manufacture": null, "raw": ["016468", "000250", "0", "2012/Mar/27 10:12", "Fondital", "Nova Florida", "Pictor Condensing KR 32 Line Tech", "", "", "2006", "current", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "30.6", "30.6", "", "", "88.9", "79.9", "", "58.4", "", "2", "1", "", "102", "1", "2", "155", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.9", "98.7", "", "", "", "", "97.1"]} -{"pcdb_id": 16469, "brand_name": "Nova Florida", "model_name": "Pictor Condensing KRB 24 Line Tech", "model_qualifier": "", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 78.9, "comparative_hot_water_efficiency_pct": 57.6, "output_kw_max": 23.1, "final_year_of_manufacture": null, "raw": ["016469", "000250", "0", "2012/Mar/27 10:12", "Fondital", "Nova Florida", "Pictor Condensing KRB 24 Line Tech", "", "", "2007", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "23.1", "23.1", "", "", "87.9", "78.9", "", "57.6", "", "2", "", "", "102", "1", "2", "155", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "96.5", "", "", "", "", "94.9"]} -{"pcdb_id": 16470, "brand_name": "Nova Florida", "model_name": "Pictor Condensing KRB 28 Line Tech", "model_qualifier": "", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 78.9, "comparative_hot_water_efficiency_pct": 57.6, "output_kw_max": 25.55, "final_year_of_manufacture": null, "raw": ["016470", "000250", "0", "2012/Mar/27 10:12", "Fondital", "Nova Florida", "Pictor Condensing KRB 28 Line Tech", "", "", "2007", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "25.55", "25.55", "", "", "87.9", "78.9", "", "57.6", "", "2", "", "", "102", "1", "2", "155", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "96.5", "", "", "", "", "94.9"]} -{"pcdb_id": 16471, "brand_name": "Nova Florida", "model_name": "Pictor Condensing KRB 28 Line Tech", "model_qualifier": "", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 25.55, "final_year_of_manufacture": null, "raw": ["016471", "000250", "0", "2012/Mar/27 10:12", "Fondital", "Nova Florida", "Pictor Condensing KRB 28 Line Tech", "", "", "2007", "current", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "25.55", "25.55", "", "", "88.9", "79.9", "", "58.3", "", "2", "1", "", "102", "1", "2", "155", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.8", "98.6", "", "", "", "", "97.0"]} -{"pcdb_id": 16472, "brand_name": "Nova Florida", "model_name": "Pictor Condensing KRB 32 Line Tech", "model_qualifier": "", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 78.9, "comparative_hot_water_efficiency_pct": 57.6, "output_kw_max": 30.6, "final_year_of_manufacture": null, "raw": ["016472", "000250", "0", "2012/Mar/27 10:12", "Fondital", "Nova Florida", "Pictor Condensing KRB 32 Line Tech", "", "", "2007", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "30.6", "30.6", "", "", "87.9", "78.9", "", "57.6", "", "2", "", "", "102", "1", "2", "155", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "96.6", "", "", "", "", "94.9"]} -{"pcdb_id": 16473, "brand_name": "Nova Florida", "model_name": "Pictor Condensing KRB 32 Line Tech", "model_qualifier": "", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 30.6, "final_year_of_manufacture": null, "raw": ["016473", "000250", "0", "2012/Mar/27 10:12", "Fondital", "Nova Florida", "Pictor Condensing KRB 32 Line Tech", "", "", "2007", "current", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "30.6", "30.6", "", "", "88.9", "79.9", "", "58.4", "", "2", "1", "", "102", "1", "2", "155", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.9", "98.7", "", "", "", "", "97.1"]} -{"pcdb_id": 16475, "brand_name": "Biasi", "model_name": "Activ A", "model_qualifier": "12OV", "winter_efficiency_pct": 87.7, "summer_efficiency_pct": 78.7, "comparative_hot_water_efficiency_pct": 57.5, "output_kw_max": 11.8, "final_year_of_manufacture": null, "raw": ["016475", "000208", "0", "2012/Jun/28 11:09", "Biasi", "Biasi", "Activ A", "12OV", "41-583-14", "2010", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "11.8", "11.8", "", "", "87.7", "78.7", "", "57.5", "", "2", "", "", "102", "1", "2", "121", "5.4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "95.9", "", "", "", "", "94.4"]} -{"pcdb_id": 16477, "brand_name": "Biasi", "model_name": "Activ A", "model_qualifier": "12OV", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 11.8, "final_year_of_manufacture": null, "raw": ["016477", "000208", "0", "2012/Mar/27 10:12", "Biasi", "Biasi", "Activ A", "12OV", "", "2010", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "11.8", "11.8", "", "", "88.7", "79.7", "", "58.2", "", "2", "1", "", "102", "1", "2", "121", "5.4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.3", "98.0", "", "", "", "", "96.5"]} -{"pcdb_id": 16478, "brand_name": "Biasi", "model_name": "Activ A", "model_qualifier": "15OV", "winter_efficiency_pct": 87.7, "summer_efficiency_pct": 78.7, "comparative_hot_water_efficiency_pct": 57.5, "output_kw_max": 14.7, "final_year_of_manufacture": null, "raw": ["016478", "000208", "0", "2012/Jun/28 11:09", "Biasi", "Biasi", "Activ A", "15OV", "41-583-15", "2010", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "14.7", "14.7", "", "", "87.7", "78.7", "", "57.5", "", "2", "", "", "102", "1", "2", "125", "5.4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.1", "96.0", "", "", "", "", "94.5"]} -{"pcdb_id": 16480, "brand_name": "Biasi", "model_name": "Activ A", "model_qualifier": "15OV", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 14.7, "final_year_of_manufacture": null, "raw": ["016480", "000208", "0", "2012/Mar/27 10:12", "Biasi", "Biasi", "Activ A", "15OV", "", "2010", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "14.7", "14.7", "", "", "88.7", "79.7", "", "58.2", "", "2", "1", "", "102", "1", "2", "125", "5.4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.1", "98.1", "", "", "", "", "96.6"]} -{"pcdb_id": 16481, "brand_name": "Biasi", "model_name": "Activ A", "model_qualifier": "20OV", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 19.5, "final_year_of_manufacture": null, "raw": ["016481", "000208", "0", "2012/Jun/28 11:09", "Biasi", "Biasi", "Activ A", "20OV", "41-583-16", "2010", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "19.5", "19.5", "", "", "88.2", "79.2", "", "57.9", "", "2", "", "", "102", "1", "2", "139", "5.4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.1", "97.3", "", "", "", "", "95.6"]} -{"pcdb_id": 16482, "brand_name": "Biasi", "model_name": "Activ A", "model_qualifier": "20OV", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 19.5, "final_year_of_manufacture": null, "raw": ["016482", "000208", "0", "2012/Mar/27 10:12", "Biasi", "Biasi", "Activ A", "20OV", "", "2010", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "19.5", "19.5", "", "", "89.2", "80.2", "", "58.6", "", "2", "1", "", "102", "1", "2", "139", "5.4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.1", "99.5", "", "", "", "", "97.7"]} -{"pcdb_id": 16483, "brand_name": "Biasi", "model_name": "Activ A", "model_qualifier": "25OV", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 24.5, "final_year_of_manufacture": null, "raw": ["016483", "000208", "0", "2012/Jun/28 11:09", "Biasi", "Biasi", "Activ A", "25OV", "41-583-17", "2010", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24.5", "24.5", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "150", "5.4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.1", "96.9", "", "", "", "", "95.2"]} -{"pcdb_id": 16484, "brand_name": "Biasi", "model_name": "Activ A", "model_qualifier": "25OV", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 24.5, "final_year_of_manufacture": null, "raw": ["016484", "000208", "0", "2012/Mar/27 10:12", "Biasi", "Biasi", "Activ A", "25OV", "", "2010", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "24.5", "24.5", "", "", "89.0", "80.0", "", "58.5", "", "2", "1", "", "102", "1", "2", "150", "5.4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.1", "99.0", "", "", "", "", "97.3"]} -{"pcdb_id": 16486, "brand_name": "Potterton", "model_name": "Gold", "model_qualifier": "H 24", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 22.0, "final_year_of_manufacture": 2015, "raw": ["016486", "000005", "0", "2015/Aug/06 12:59", "Baxi Heating UK", "Potterton", "Gold", "H 24", "GC No 41-592-14", "2010", "2015", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "22.0", "22.0", "", "", "88.1", "79.1", "", "57.8", "", "2", "", "", "102", "1", "2", "80", "2.49", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.5", "96.5", "", "", "", "", "95.2"]} -{"pcdb_id": 16487, "brand_name": "Potterton", "model_name": "Gold", "model_qualifier": "H 18", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 17.81, "final_year_of_manufacture": 2015, "raw": ["016487", "000005", "0", "2015/Aug/06 13:00", "Baxi Heating UK", "Potterton", "Gold", "H 18", "GC No 41-592-13", "2010", "2015", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "17.81", "17.81", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "80", "2.49", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "96.8", "", "", "", "", "95.2"]} -{"pcdb_id": 16488, "brand_name": "Potterton", "model_name": "Gold", "model_qualifier": "H 15", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 15.24, "final_year_of_manufacture": 2015, "raw": ["016488", "000005", "0", "2015/Aug/06 13:00", "Baxi Heating UK", "Potterton", "Gold", "H 15", "GC No 41-592-12", "2010", "2015", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "15.24", "15.24", "", "", "88.3", "79.3", "", "57.9", "", "2", "", "", "102", "1", "2", "80", "2.49", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.3", "96.5", "", "", "", "", "95.3"]} -{"pcdb_id": 16489, "brand_name": "Nova Florida", "model_name": "Pictor Condensing KRB 24 Line Tech", "model_qualifier": "", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 23.1, "final_year_of_manufacture": null, "raw": ["016489", "000250", "0", "2012/Mar/27 10:12", "Fondital", "Nova Florida", "Pictor Condensing KRB 24 Line Tech", "", "", "2001", "current", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "23.1", "23.1", "", "", "88.9", "79.9", "", "58.3", "", "2", "1", "", "102", "1", "2", "155", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.8", "98.6", "", "", "", "", "97.0"]} -{"pcdb_id": 16490, "brand_name": "Baxi Heating", "model_name": "Bermuda", "model_qualifier": "45/3M", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 13.19, "final_year_of_manufacture": 1997, "raw": ["016490", "000005", "0", "2010/Sep/13 17:32", "Baxi Heating", "Baxi Heating", "Bermuda", "45/3M", "4407761", "1995", "1997", "1", "4", "1", "1", "0", "", "", "1", "1", "1", "10.26", "13.19", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "1", "", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 16491, "brand_name": "Baxi Heating", "model_name": "Bermuda", "model_qualifier": "57/3M", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 16.85, "final_year_of_manufacture": 1997, "raw": ["016491", "000005", "0", "2010/Sep/13 17:32", "Baxi Heating", "Baxi Heating", "Bermuda", "57/3M", "4407763", "1995", "1997", "1", "4", "1", "1", "0", "", "", "1", "1", "1", "13.19", "16.85", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "1", "", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 16492, "brand_name": "Baxi Heating", "model_name": "Bermuda", "model_qualifier": "45/3E", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 13.19, "final_year_of_manufacture": 1997, "raw": ["016492", "000005", "0", "2010/Sep/13 17:32", "Baxi Heating", "Baxi Heating", "Bermuda", "45/3E", "4407760", "1995", "1997", "1", "4", "1", "1", "0", "", "", "1", "1", "1", "10.26", "13.19", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "1", "1", "", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 16493, "brand_name": "Baxi Heating", "model_name": "Bermuda", "model_qualifier": "57/3E", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 16.85, "final_year_of_manufacture": 1997, "raw": ["016493", "000005", "0", "2010/Sep/13 17:32", "Baxi Heating", "Baxi Heating", "Bermuda", "57/3E", "4407762", "1995", "1997", "1", "4", "1", "1", "0", "", "", "1", "1", "1", "13.19", "16.85", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "1", "1", "", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 16494, "brand_name": "Baxi Heating", "model_name": "Bermuda", "model_qualifier": "25/1", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 7.3, "final_year_of_manufacture": 1995, "raw": ["016494", "000005", "0", "2010/Sep/13 17:32", "Baxi Heating", "Baxi Heating", "Bermuda", "25/1", "4407751", "1985", "1995", "1", "4", "1", "1", "0", "", "", "1", "1", "1", "4.40", "7.30", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "1", "1", "", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 16495, "brand_name": "Baxi Heating", "model_name": "Bermuda", "model_qualifier": "401", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 11.7, "final_year_of_manufacture": 1995, "raw": ["016495", "000005", "0", "2010/Sep/13 17:32", "Baxi Heating", "Baxi Heating", "Bermuda", "401", "4407749", "1977", "1995", "1", "4", "1", "1", "0", "", "", "1", "1", "1", "4.40", "11.70", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "1", "1", "", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 16496, "brand_name": "Baxi Heating", "model_name": "Bermuda", "model_qualifier": "551", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 16.0, "final_year_of_manufacture": 1980, "raw": ["016496", "000005", "0", "2010/Sep/13 17:32", "Baxi Heating", "Baxi Heating", "Bermuda", "551", "4407748", "1976", "1980", "1", "4", "1", "1", "0", "", "", "1", "1", "1", "10.00", "16.00", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "1", "1", "", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 16497, "brand_name": "Baxi Heating", "model_name": "Bermuda", "model_qualifier": "552", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 16.0, "final_year_of_manufacture": 1995, "raw": ["016497", "000005", "0", "2010/Sep/13 17:32", "Baxi Heating", "Baxi Heating", "Bermuda", "552", "4407750", "1980", "1995", "1", "4", "1", "1", "0", "", "", "1", "1", "1", "10.00", "16.00", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "1", "1", "", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 16498, "brand_name": "Baxi Heating", "model_name": "Solo", "model_qualifier": "20/4 RS", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 5.86, "final_year_of_manufacture": 1993, "raw": ["016498", "000005", "0", "2010/Sep/13 17:32", "Baxi Heating", "Baxi Heating", "Solo", "20/4 RS", "4107746", "1989", "1993", "1", "2", "1", "1", "0", "", "", "1", "2", "1", "3.22", "5.86", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "1", "", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 16499, "brand_name": "Baxi Heating", "model_name": "Solo", "model_qualifier": "30/4 RS", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 8.79, "final_year_of_manufacture": 1993, "raw": ["016499", "000005", "0", "2010/Sep/13 17:32", "Baxi Heating", "Baxi Heating", "Solo", "30/4 RS", "4107747", "1989", "1993", "1", "2", "1", "1", "0", "", "", "1", "2", "1", "6.15", "8.79", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "1", "", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 16500, "brand_name": "Baxi Heating", "model_name": "Solo", "model_qualifier": "40/4 RS", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 11.72, "final_year_of_manufacture": 1993, "raw": ["016500", "000005", "0", "2010/Sep/13 17:32", "Baxi Heating", "Baxi Heating", "Solo", "40/4 RS", "4107748", "1989", "1993", "1", "2", "1", "1", "0", "", "", "1", "2", "1", "9.09", "11.72", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "1", "", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 16501, "brand_name": "Baxi Heating", "model_name": "Solo", "model_qualifier": "50/4 RS", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 14.7, "final_year_of_manufacture": 1993, "raw": ["016501", "000005", "0", "2010/Sep/13 17:32", "Baxi Heating", "Baxi Heating", "Solo", "50/4 RS", "4107749", "1989", "1993", "1", "2", "1", "1", "0", "", "", "1", "2", "1", "12", "14.7", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "1", "", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 16502, "brand_name": "Baxi Heating", "model_name": "Solo", "model_qualifier": "60/4 RS", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 17.58, "final_year_of_manufacture": 1993, "raw": ["016502", "000005", "0", "2010/Sep/13 17:32", "Baxi Heating", "Baxi Heating", "Solo", "60/4 RS", "4107750", "1989", "1993", "1", "2", "1", "1", "0", "", "", "1", "2", "1", "14.95", "17.58", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "1", "", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 16503, "brand_name": "Baxi Heating", "model_name": "Solo", "model_qualifier": "20/4 RS SS", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 5.86, "final_year_of_manufacture": 1994, "raw": ["016503", "000005", "0", "2010/Sep/13 17:32", "Baxi Heating", "Baxi Heating", "Solo", "20/4 RS SS", "4107756", "1991", "1994", "1", "2", "1", "1", "0", "", "", "1", "2", "1", "3.22", "5.86", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "1", "", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 16504, "brand_name": "Baxi Heating", "model_name": "Solo", "model_qualifier": "30/4 RS SS", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 8.79, "final_year_of_manufacture": 1994, "raw": ["016504", "000005", "0", "2010/Sep/13 17:32", "Baxi Heating", "Baxi Heating", "Solo", "30/4 RS SS", "4107757", "1991", "1994", "1", "2", "1", "1", "0", "", "", "1", "2", "1", "6.15", "8.79", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "1", "", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 16505, "brand_name": "Baxi Heating", "model_name": "Solo", "model_qualifier": "40/4 RS SS", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 11.72, "final_year_of_manufacture": 1994, "raw": ["016505", "000005", "0", "2010/Sep/13 17:32", "Baxi Heating", "Baxi Heating", "Solo", "40/4 RS SS", "4107758", "1991", "1994", "1", "2", "1", "1", "0", "", "", "1", "2", "1", "9.09", "11.72", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "1", "", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 16506, "brand_name": "Baxi Heating", "model_name": "Solo", "model_qualifier": "50/4 RS SS", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 14.7, "final_year_of_manufacture": 1994, "raw": ["016506", "000005", "0", "2010/Sep/13 17:32", "Baxi Heating", "Baxi Heating", "Solo", "50/4 RS SS", "4107759", "1991", "1994", "1", "2", "1", "1", "0", "", "", "1", "2", "1", "12", "14.7", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "1", "", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 16507, "brand_name": "Baxi Heating", "model_name": "Solo", "model_qualifier": "60/4 RS SS", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 17.58, "final_year_of_manufacture": 1994, "raw": ["016507", "000005", "0", "2010/Sep/13 17:32", "Baxi Heating", "Baxi Heating", "Solo", "60/4 RS SS", "4107760", "1991", "1994", "1", "2", "1", "1", "0", "", "", "1", "2", "1", "14.95", "17.58", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "1", "", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 16508, "brand_name": "Baxi Heating", "model_name": "Solo", "model_qualifier": "WM 30/4 PF", "winter_efficiency_pct": 69.0, "summer_efficiency_pct": 59.0, "comparative_hot_water_efficiency_pct": 43.0, "output_kw_max": 8.79, "final_year_of_manufacture": 1993, "raw": ["016508", "000005", "0", "2010/Sep/13 17:32", "Baxi Heating", "Baxi Heating", "Solo", "WM 30/4 PF", "4107752", "1990", "1993", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "6.15", "8.79", "", "", "69.0", "59.0", "", "43.0", "", "3", "", "", "0", "1", "1", "", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 16509, "brand_name": "Baxi Heating", "model_name": "Solo", "model_qualifier": "WM 40/4 PF", "winter_efficiency_pct": 69.0, "summer_efficiency_pct": 59.0, "comparative_hot_water_efficiency_pct": 43.0, "output_kw_max": 11.72, "final_year_of_manufacture": 1993, "raw": ["016509", "000005", "0", "2010/Sep/13 17:32", "Baxi Heating", "Baxi Heating", "Solo", "WM 40/4 PF", "4107753", "1990", "1993", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "9.08", "11.72", "", "", "69.0", "59.0", "", "43.0", "", "3", "", "", "0", "1", "1", "", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 16510, "brand_name": "Baxi Heating", "model_name": "Solo", "model_qualifier": "WM 50/4 PF", "winter_efficiency_pct": 69.0, "summer_efficiency_pct": 59.0, "comparative_hot_water_efficiency_pct": 43.0, "output_kw_max": 14.65, "final_year_of_manufacture": 1993, "raw": ["016510", "000005", "0", "2010/Sep/13 17:32", "Baxi Heating", "Baxi Heating", "Solo", "WM 50/4 PF", "4107754", "1990", "1993", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "12.02", "14.65", "", "", "69.0", "59.0", "", "43.0", "", "3", "", "", "0", "1", "1", "", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 16511, "brand_name": "Baxi Heating", "model_name": "Solo", "model_qualifier": "WM 70/4 PF", "winter_efficiency_pct": 69.0, "summer_efficiency_pct": 59.0, "comparative_hot_water_efficiency_pct": 43.0, "output_kw_max": 20.5, "final_year_of_manufacture": 1993, "raw": ["016511", "000005", "0", "2010/Sep/13 17:32", "Baxi Heating", "Baxi Heating", "Solo", "WM 70/4 PF", "4107755", "1990", "1993", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "15", "20.5", "", "", "69.0", "59.0", "", "43.0", "", "3", "", "", "0", "1", "1", "", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 16512, "brand_name": "Baxi Heating", "model_name": "Solo 2", "model_qualifier": "30 PF", "winter_efficiency_pct": 69.0, "summer_efficiency_pct": 59.0, "comparative_hot_water_efficiency_pct": 43.0, "output_kw_max": 8.79, "final_year_of_manufacture": 1999, "raw": ["016512", "000005", "0", "2010/Sep/13 17:32", "Baxi Heating", "Baxi Heating", "Solo 2", "30 PF", "4107771", "1993", "1999", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "5.86", "8.79", "", "", "69.0", "59.0", "", "43.0", "", "3", "", "", "0", "1", "1", "", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 16513, "brand_name": "Baxi Heating", "model_name": "Solo 2", "model_qualifier": "40 PF", "winter_efficiency_pct": 69.0, "summer_efficiency_pct": 59.0, "comparative_hot_water_efficiency_pct": 43.0, "output_kw_max": 11.72, "final_year_of_manufacture": 1999, "raw": ["016513", "000005", "0", "2010/Sep/13 17:32", "Baxi Heating", "Baxi Heating", "Solo 2", "40 PF", "4107772", "1993", "1999", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "9.09", "11.72", "", "", "69.0", "59.0", "", "43.0", "", "3", "", "", "0", "1", "1", "", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 16514, "brand_name": "Baxi Heating", "model_name": "Solo 2", "model_qualifier": "50 PF", "winter_efficiency_pct": 69.0, "summer_efficiency_pct": 59.0, "comparative_hot_water_efficiency_pct": 43.0, "output_kw_max": 14.65, "final_year_of_manufacture": 1999, "raw": ["016514", "000005", "0", "2010/Sep/13 17:32", "Baxi Heating", "Baxi Heating", "Solo 2", "50 PF", "4107773", "1993", "1999", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "12.02", "14.65", "", "", "69.0", "59.0", "", "43.0", "", "3", "", "", "0", "1", "1", "", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 16515, "brand_name": "Baxi Heating", "model_name": "Solo 2", "model_qualifier": "60 PF", "winter_efficiency_pct": 69.0, "summer_efficiency_pct": 59.0, "comparative_hot_water_efficiency_pct": 43.0, "output_kw_max": 17.58, "final_year_of_manufacture": 1999, "raw": ["016515", "000005", "0", "2010/Sep/13 17:32", "Baxi Heating", "Baxi Heating", "Solo 2", "60 PF", "4107774", "1993", "1999", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "14.95", "17.58", "", "", "69.0", "59.0", "", "43.0", "", "3", "", "", "0", "1", "1", "", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 16516, "brand_name": "Baxi Heating", "model_name": "Solo 2", "model_qualifier": "70 PF", "winter_efficiency_pct": 69.0, "summer_efficiency_pct": 59.0, "comparative_hot_water_efficiency_pct": 43.0, "output_kw_max": 20.5, "final_year_of_manufacture": 1999, "raw": ["016516", "000005", "0", "2010/Sep/13 17:32", "Baxi Heating", "Baxi Heating", "Solo 2", "70 PF", "4107501", "1993", "1999", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "17.88", "20.5", "", "", "69.0", "59.0", "", "43.0", "", "3", "", "", "0", "1", "1", "", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 16517, "brand_name": "Baxi Heating", "model_name": "Solo 2", "model_qualifier": "80 PF", "winter_efficiency_pct": 69.0, "summer_efficiency_pct": 59.0, "comparative_hot_water_efficiency_pct": 43.0, "output_kw_max": 23.45, "final_year_of_manufacture": 1999, "raw": ["016517", "000005", "0", "2010/Sep/13 17:32", "Baxi Heating", "Baxi Heating", "Solo 2", "80 PF", "4107775", "1993", "1999", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "20.8", "23.45", "", "", "69.0", "59.0", "", "43.0", "", "3", "", "", "0", "1", "1", "", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 16518, "brand_name": "Baxi Heating", "model_name": "Solo 2", "model_qualifier": "30 RS", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 8.79, "final_year_of_manufacture": 2001, "raw": ["016518", "000005", "0", "2010/Sep/13 17:32", "Baxi Heating", "Baxi Heating", "Solo 2", "30 RS", "4107776", "1994", "2001", "1", "2", "1", "1", "0", "", "", "1", "2", "1", "6.15", "8.79", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "1", "", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 16519, "brand_name": "Baxi Heating", "model_name": "Solo 2", "model_qualifier": "40 RS", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 11.72, "final_year_of_manufacture": 2001, "raw": ["016519", "000005", "0", "2010/Sep/13 17:32", "Baxi Heating", "Baxi Heating", "Solo 2", "40 RS", "4107777", "1994", "2001", "1", "2", "1", "1", "0", "", "", "1", "2", "1", "9.09", "11.72", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "1", "", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 16520, "brand_name": "Baxi Heating", "model_name": "Solo 2", "model_qualifier": "50 RS", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 14.65, "final_year_of_manufacture": 2001, "raw": ["016520", "000005", "0", "2010/Sep/13 17:32", "Baxi Heating", "Baxi Heating", "Solo 2", "50 RS", "4107778", "1994", "2001", "1", "2", "1", "1", "0", "", "", "1", "2", "1", "12.02", "14.65", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "1", "", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 16521, "brand_name": "Baxi Heating", "model_name": "Solo 2", "model_qualifier": "60 RS", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 17.58, "final_year_of_manufacture": 2001, "raw": ["016521", "000005", "0", "2010/Sep/13 17:32", "Baxi Heating", "Baxi Heating", "Solo 2", "60 RS", "4107779", "1994", "2001", "1", "2", "1", "1", "0", "", "", "1", "2", "1", "14.95", "17.58", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "1", "", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 16522, "brand_name": "Baxi Heating", "model_name": "Boston", "model_qualifier": "40 RS", "winter_efficiency_pct": 56.0, "summer_efficiency_pct": 46.0, "comparative_hot_water_efficiency_pct": 33.5, "output_kw_max": 11.7, "final_year_of_manufacture": 1995, "raw": ["016522", "000005", "0", "2010/Sep/13 17:32", "Baxi Heating", "Baxi Heating", "Boston", "40 RS", "4107766", "1993", "1995", "1", "1", "1", "1", "0", "", "", "1", "2", "1", "9.1", "11.7", "", "", "56.0", "46.0", "", "33.5", "", "3", "", "", "0", "2", "1", "", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 16523, "brand_name": "Baxi Heating", "model_name": "Boston", "model_qualifier": "50 RS", "winter_efficiency_pct": 56.0, "summer_efficiency_pct": 46.0, "comparative_hot_water_efficiency_pct": 33.5, "output_kw_max": 14.65, "final_year_of_manufacture": 1995, "raw": ["016523", "000005", "0", "2010/Sep/13 17:32", "Baxi Heating", "Baxi Heating", "Boston", "50 RS", "4107767", "1993", "1995", "1", "1", "1", "1", "0", "", "", "1", "2", "1", "12.02", "14.65", "", "", "56.0", "46.0", "", "33.5", "", "3", "", "", "0", "2", "1", "", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 16524, "brand_name": "Baxi Heating", "model_name": "Boston", "model_qualifier": "60 RS", "winter_efficiency_pct": 56.0, "summer_efficiency_pct": 46.0, "comparative_hot_water_efficiency_pct": 33.5, "output_kw_max": 17.6, "final_year_of_manufacture": 1995, "raw": ["016524", "000005", "0", "2010/Sep/13 17:32", "Baxi Heating", "Baxi Heating", "Boston", "60 RS", "4107768", "1993", "1995", "1", "1", "1", "1", "0", "", "", "1", "2", "1", "14.95", "17.6", "", "", "56.0", "46.0", "", "33.5", "", "3", "", "", "0", "2", "1", "", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 16525, "brand_name": "Baxi Heating", "model_name": "Boston", "model_qualifier": "70 RS", "winter_efficiency_pct": 56.0, "summer_efficiency_pct": 46.0, "comparative_hot_water_efficiency_pct": 33.5, "output_kw_max": 20.5, "final_year_of_manufacture": 1995, "raw": ["016525", "000005", "0", "2010/Sep/13 17:32", "Baxi Heating", "Baxi Heating", "Boston", "70 RS", "4107769", "1993", "1995", "1", "1", "1", "1", "0", "", "", "1", "2", "1", "17.8", "20.5", "", "", "56.0", "46.0", "", "33.5", "", "3", "", "", "0", "2", "1", "", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 16526, "brand_name": "Baxi Heating", "model_name": "Boston", "model_qualifier": "80 RS", "winter_efficiency_pct": 56.0, "summer_efficiency_pct": 46.0, "comparative_hot_water_efficiency_pct": 33.5, "output_kw_max": 23.4, "final_year_of_manufacture": 1995, "raw": ["016526", "000005", "0", "2010/Sep/13 17:32", "Baxi Heating", "Baxi Heating", "Boston", "80 RS", "4107770", "1993", "1995", "1", "1", "1", "1", "0", "", "", "1", "2", "1", "20.8", "23.4", "", "", "56.0", "46.0", "", "33.5", "", "3", "", "", "0", "2", "1", "", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 16527, "brand_name": "Baxi Heating", "model_name": "Boston", "model_qualifier": "40 OF", "winter_efficiency_pct": 56.0, "summer_efficiency_pct": 46.0, "comparative_hot_water_efficiency_pct": 33.5, "output_kw_max": 11.7, "final_year_of_manufacture": 1995, "raw": ["016527", "000005", "0", "2010/Sep/13 17:32", "Baxi Heating", "Baxi Heating", "Boston", "40 OF", "4107761", "1993", "1995", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "9.1", "11.7", "", "", "56.0", "46.0", "", "33.5", "", "3", "", "", "0", "2", "1", "", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 16528, "brand_name": "Baxi Heating", "model_name": "Boston", "model_qualifier": "50 OF", "winter_efficiency_pct": 56.0, "summer_efficiency_pct": 46.0, "comparative_hot_water_efficiency_pct": 33.5, "output_kw_max": 14.65, "final_year_of_manufacture": 1995, "raw": ["016528", "000005", "0", "2010/Sep/13 17:32", "Baxi Heating", "Baxi Heating", "Boston", "50 OF", "4107762", "1993", "1995", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "12.02", "14.65", "", "", "56.0", "46.0", "", "33.5", "", "3", "", "", "0", "2", "1", "", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 16529, "brand_name": "Baxi Heating", "model_name": "Boston", "model_qualifier": "60 OF", "winter_efficiency_pct": 56.0, "summer_efficiency_pct": 46.0, "comparative_hot_water_efficiency_pct": 33.5, "output_kw_max": 17.6, "final_year_of_manufacture": 1995, "raw": ["016529", "000005", "0", "2010/Sep/13 17:32", "Baxi Heating", "Baxi Heating", "Boston", "60 OF", "4107763", "1993", "1995", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "14.95", "17.6", "", "", "56.0", "46.0", "", "33.5", "", "3", "", "", "0", "2", "1", "", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 16530, "brand_name": "Baxi Heating", "model_name": "Boston", "model_qualifier": "70 OF", "winter_efficiency_pct": 56.0, "summer_efficiency_pct": 46.0, "comparative_hot_water_efficiency_pct": 33.5, "output_kw_max": 20.5, "final_year_of_manufacture": 1995, "raw": ["016530", "000005", "0", "2010/Sep/13 17:32", "Baxi Heating", "Baxi Heating", "Boston", "70 OF", "4107764", "1993", "1995", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "17.8", "20.5", "", "", "56.0", "46.0", "", "33.5", "", "3", "", "", "0", "2", "1", "", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 16531, "brand_name": "Baxi Heating", "model_name": "Boston", "model_qualifier": "80 OF", "winter_efficiency_pct": 56.0, "summer_efficiency_pct": 46.0, "comparative_hot_water_efficiency_pct": 33.5, "output_kw_max": 23.4, "final_year_of_manufacture": 1995, "raw": ["016531", "000005", "0", "2010/Sep/13 17:32", "Baxi Heating", "Baxi Heating", "Boston", "80 OF", "4107765", "1993", "1995", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "20.8", "23.4", "", "", "56.0", "46.0", "", "33.5", "", "3", "", "", "0", "2", "1", "", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 16532, "brand_name": "Baxi Heating", "model_name": "Boston 2", "model_qualifier": "40 RS", "winter_efficiency_pct": 56.0, "summer_efficiency_pct": 46.0, "comparative_hot_water_efficiency_pct": 33.5, "output_kw_max": 11.72, "final_year_of_manufacture": 2001, "raw": ["016532", "000005", "0", "2010/Sep/13 17:32", "Baxi Heating", "Baxi Heating", "Boston 2", "40 RS", "4107785", "1995", "2001", "1", "1", "1", "1", "0", "", "", "1", "2", "1", "9.08", "11.72", "", "", "56.0", "46.0", "", "33.5", "", "3", "", "", "0", "2", "1", "", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 16533, "brand_name": "Baxi Heating", "model_name": "Boston 2", "model_qualifier": "50 RS", "winter_efficiency_pct": 56.0, "summer_efficiency_pct": 46.0, "comparative_hot_water_efficiency_pct": 33.5, "output_kw_max": 14.65, "final_year_of_manufacture": 2001, "raw": ["016533", "000005", "0", "2010/Sep/13 17:32", "Baxi Heating", "Baxi Heating", "Boston 2", "50 RS", "4107786", "1995", "2001", "1", "1", "1", "1", "0", "", "", "1", "2", "1", "12.02", "14.65", "", "", "56.0", "46.0", "", "33.5", "", "3", "", "", "0", "2", "1", "", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 16534, "brand_name": "Baxi Heating", "model_name": "Boston 2", "model_qualifier": "60 RS", "winter_efficiency_pct": 56.0, "summer_efficiency_pct": 46.0, "comparative_hot_water_efficiency_pct": 33.5, "output_kw_max": 17.58, "final_year_of_manufacture": 2001, "raw": ["016534", "000005", "0", "2010/Sep/13 17:32", "Baxi Heating", "Baxi Heating", "Boston 2", "60 RS", "4107787", "1995", "2001", "1", "1", "1", "1", "0", "", "", "1", "2", "1", "14.95", "17.58", "", "", "56.0", "46.0", "", "33.5", "", "3", "", "", "0", "2", "1", "", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 16535, "brand_name": "Baxi Heating", "model_name": "Boston 2", "model_qualifier": "70 RS", "winter_efficiency_pct": 56.0, "summer_efficiency_pct": 46.0, "comparative_hot_water_efficiency_pct": 33.5, "output_kw_max": 20.51, "final_year_of_manufacture": 2001, "raw": ["016535", "000005", "0", "2010/Sep/13 17:32", "Baxi Heating", "Baxi Heating", "Boston 2", "70 RS", "4107788", "1995", "2001", "1", "1", "1", "1", "0", "", "", "1", "2", "1", "17.88", "20.51", "", "", "56.0", "46.0", "", "33.5", "", "3", "", "", "0", "2", "1", "", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 16536, "brand_name": "Baxi Heating", "model_name": "Boston 2", "model_qualifier": "80 RS", "winter_efficiency_pct": 56.0, "summer_efficiency_pct": 46.0, "comparative_hot_water_efficiency_pct": 33.5, "output_kw_max": 23.45, "final_year_of_manufacture": 2001, "raw": ["016536", "000005", "0", "2010/Sep/13 17:32", "Baxi Heating", "Baxi Heating", "Boston 2", "80 RS", "4107789", "1995", "2001", "1", "1", "1", "1", "0", "", "", "1", "2", "1", "20.81", "23.45", "", "", "56.0", "46.0", "", "33.5", "", "3", "", "", "0", "2", "1", "", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 16537, "brand_name": "Baxi Heating", "model_name": "Boston 2", "model_qualifier": "40 OF", "winter_efficiency_pct": 56.0, "summer_efficiency_pct": 46.0, "comparative_hot_water_efficiency_pct": 33.5, "output_kw_max": 11.72, "final_year_of_manufacture": 2001, "raw": ["016537", "000005", "0", "2010/Sep/13 17:32", "Baxi Heating", "Baxi Heating", "Boston 2", "40 OF", "4107780", "1995", "2001", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "9.08", "11.72", "", "", "56.0", "46.0", "", "33.5", "", "3", "", "", "0", "2", "1", "", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 16538, "brand_name": "Baxi Heating", "model_name": "Boston 2", "model_qualifier": "50 OF", "winter_efficiency_pct": 56.0, "summer_efficiency_pct": 46.0, "comparative_hot_water_efficiency_pct": 33.5, "output_kw_max": 14.65, "final_year_of_manufacture": 2001, "raw": ["016538", "000005", "0", "2010/Sep/13 17:32", "Baxi Heating", "Baxi Heating", "Boston 2", "50 OF", "4107781", "1995", "2001", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "12.02", "14.65", "", "", "56.0", "46.0", "", "33.5", "", "3", "", "", "0", "2", "1", "", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 16539, "brand_name": "Baxi Heating", "model_name": "Boston 2", "model_qualifier": "60 OF", "winter_efficiency_pct": 56.0, "summer_efficiency_pct": 46.0, "comparative_hot_water_efficiency_pct": 33.5, "output_kw_max": 17.58, "final_year_of_manufacture": 2001, "raw": ["016539", "000005", "0", "2010/Sep/13 17:32", "Baxi Heating", "Baxi Heating", "Boston 2", "60 OF", "4107782", "1995", "2001", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "14.95", "17.58", "", "", "56.0", "46.0", "", "33.5", "", "3", "", "", "0", "2", "1", "", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 16540, "brand_name": "Baxi Heating", "model_name": "Boston 2", "model_qualifier": "70 OF", "winter_efficiency_pct": 56.0, "summer_efficiency_pct": 46.0, "comparative_hot_water_efficiency_pct": 33.5, "output_kw_max": 20.51, "final_year_of_manufacture": 2001, "raw": ["016540", "000005", "0", "2010/Sep/13 17:32", "Baxi Heating", "Baxi Heating", "Boston 2", "70 OF", "4107783", "1995", "2001", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "17.88", "20.51", "", "", "56.0", "46.0", "", "33.5", "", "3", "", "", "0", "2", "1", "", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 16541, "brand_name": "Baxi Heating", "model_name": "Boston 2", "model_qualifier": "80 OF", "winter_efficiency_pct": 56.0, "summer_efficiency_pct": 46.0, "comparative_hot_water_efficiency_pct": 33.5, "output_kw_max": 23.45, "final_year_of_manufacture": 2001, "raw": ["016541", "000005", "0", "2010/Sep/13 17:32", "Baxi Heating", "Baxi Heating", "Boston 2", "80 OF", "4107784", "1995", "2001", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "20.81", "23.45", "", "", "56.0", "46.0", "", "33.5", "", "3", "", "", "0", "2", "1", "", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 16542, "brand_name": "Baxi Heating", "model_name": "Genesis", "model_qualifier": "80", "winter_efficiency_pct": 71.0, "summer_efficiency_pct": 62.0, "comparative_hot_water_efficiency_pct": 43.2, "output_kw_max": 23.25, "final_year_of_manufacture": 2000, "raw": ["016542", "000005", "0", "2010/Sep/13 17:32", "Baxi Heating", "Baxi Heating", "Genesis", "80", "4707701", "1995", "2000", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "23.25", "23.25", "", "", "71.0", "62.0", "", "43.2", "", "3", "", "", "0", "2", "1", "", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 16543, "brand_name": "Baxi Heating", "model_name": "Genesis", "model_qualifier": "96", "winter_efficiency_pct": 71.0, "summer_efficiency_pct": 62.0, "comparative_hot_water_efficiency_pct": 43.2, "output_kw_max": 28.0, "final_year_of_manufacture": 1998, "raw": ["016543", "000005", "0", "2010/Sep/13 17:32", "Baxi Heating", "Baxi Heating", "Genesis", "96", "4707702", "1996", "1998", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "28", "28", "", "", "71.0", "62.0", "", "43.2", "", "3", "", "", "0", "2", "1", "", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 16544, "brand_name": "Baxi", "model_name": "Combi", "model_qualifier": "105 HE A", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 55.9, "output_kw_max": 28.63, "final_year_of_manufacture": 2012, "raw": ["016544", "000005", "0", "2013/May/07 10:37", "Baxi Heating UK", "Baxi", "Combi", "105 HE A", "GC No. 47-075-50", "2010", "2012", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28.63", "28.63", "", "", "88.1", "79.5", "", "55.9", "", "2", "", "", "104", "1", "2", "150", "4.09", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "97.0", "", "", "", "", "95.3"]} -{"pcdb_id": 16545, "brand_name": "Potterton", "model_name": "Gold Combi", "model_qualifier": "28 HE LPG", "winter_efficiency_pct": 90.4, "summer_efficiency_pct": 81.8, "comparative_hot_water_efficiency_pct": 57.5, "output_kw_max": 24.0, "final_year_of_manufacture": null, "raw": ["016545", "000005", "0", "2010/Oct/27 07:56", "Baxi Heating UK", "Potterton", "Gold Combi", "28 HE LPG", "GC No. 47-393-30", "2010", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24.0", "24.0", "", "", "90.4", "81.8", "", "57.5", "", "2", "0", "", "104", "1", "2", "155", "4.75", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "92.0", "99.0", "", "", "", "", "97.7"]} -{"pcdb_id": 16546, "brand_name": "Potterton", "model_name": "Gold System", "model_qualifier": "28 HE A", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 28.0, "final_year_of_manufacture": 2015, "raw": ["016546", "000005", "0", "2015/Aug/06 13:01", "Baxi Heating UK", "Potterton", "Gold System", "28 HE A", "GC No. 41-592-17", "2010", "2015", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "28.0", "28.0", "", "", "88.3", "79.3", "", "57.9", "", "2", "", "", "102", "1", "2", "160", "8.32", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.9", "96.7", "", "", "", "", "95.4"]} -{"pcdb_id": 16547, "brand_name": "Potterton", "model_name": "Gold System", "model_qualifier": "24 HE A", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 24.0, "final_year_of_manufacture": 2015, "raw": ["016547", "000005", "0", "2015/Aug/06 13:02", "Baxi Heating UK", "Potterton", "Gold System", "24 HE A", "GC No. 41-592-16", "2010", "2015", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24.0", "24.0", "", "", "88.3", "79.3", "", "58.0", "", "2", "", "", "102", "1", "2", "150", "7.58", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.9", "96.9", "", "", "", "", "95.5"]} -{"pcdb_id": 16548, "brand_name": "Potterton", "model_name": "Gold System", "model_qualifier": "18 HE A", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 18.0, "final_year_of_manufacture": 2015, "raw": ["016548", "000005", "0", "2015/Aug/06 13:03", "Baxi Heating UK", "Potterton", "Gold System", "18 HE A", "GC No. 41-592-15", "2010", "2015", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18.00", "18.00", "", "", "88.3", "79.3", "", "58.0", "", "2", "", "", "102", "1", "2", "140", "7.57", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.9", "96.9", "", "", "", "", "95.5"]} -{"pcdb_id": 16549, "brand_name": "Grant", "model_name": "Vortex 26-36 Boilerhouse", "model_qualifier": "", "winter_efficiency_pct": 90.5, "summer_efficiency_pct": 82.7, "comparative_hot_water_efficiency_pct": 60.4, "output_kw_max": 36.0, "final_year_of_manufacture": null, "raw": ["016549", "000048", "0", "2012/Mar/27 10:12", "Grant Engineering UK Ltd", "Grant", "Vortex 26-36 Boilerhouse", "", "", "2010", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "26", "36", "", "", "90.5", "82.7", "", "60.4", "", "2", "", "", "201", "1", "1", "26", "36", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "95.1", "99.3", "", "", "", "", "98.5"]} -{"pcdb_id": 16550, "brand_name": "Grant", "model_name": "Vortex 26-36 Boilerhouse System", "model_qualifier": "", "winter_efficiency_pct": 90.5, "summer_efficiency_pct": 82.7, "comparative_hot_water_efficiency_pct": 60.4, "output_kw_max": 36.0, "final_year_of_manufacture": null, "raw": ["016550", "000048", "0", "2012/Mar/27 10:12", "Grant Engineering UK Ltd", "Grant", "Vortex 26-36 Boilerhouse System", "", "", "2010", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "26", "36", "", "", "90.5", "82.7", "", "60.4", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "95.1", "99.8", "", "", "", "", "98.9"]} -{"pcdb_id": 16551, "brand_name": "Grant", "model_name": "Vortex 26-36 Outdoor Module System", "model_qualifier": "", "winter_efficiency_pct": 90.5, "summer_efficiency_pct": 82.7, "comparative_hot_water_efficiency_pct": 60.4, "output_kw_max": 36.0, "final_year_of_manufacture": null, "raw": ["016551", "000048", "0", "2012/Mar/27 10:12", "Grant Engineering UK Ltd", "Grant", "Vortex 26-36 Outdoor Module System", "", "", "2010", "current", "4", "1", "2", "1", "0", "", "", "2", "3", "2", "26", "36", "", "", "90.5", "82.7", "", "60.4", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "95.1", "99.3", "", "", "", "", "98.5"]} -{"pcdb_id": 16552, "brand_name": "Grant", "model_name": "Vortex 20G Utility", "model_qualifier": "", "winter_efficiency_pct": 90.1, "summer_efficiency_pct": 82.3, "comparative_hot_water_efficiency_pct": 60.1, "output_kw_max": 20.0, "final_year_of_manufacture": null, "raw": ["016552", "000048", "0", "2012/Mar/27 10:12", "Grant Engineering UK Ltd", "Grant", "Vortex 20G Utility", "", "", "2010", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "20", "20", "", "", "90.1", "82.3", "", "60.1", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "93.1", "99.0", "", "", "", "", "97.9"]} -{"pcdb_id": 16553, "brand_name": "Grant", "model_name": "Vortex 20G Utility System", "model_qualifier": "", "winter_efficiency_pct": 90.1, "summer_efficiency_pct": 82.3, "comparative_hot_water_efficiency_pct": 60.1, "output_kw_max": 20.0, "final_year_of_manufacture": null, "raw": ["016553", "000048", "0", "2012/Mar/27 10:12", "Grant Engineering (UK)", "Grant", "Vortex 20G Utility System", "", "", "2010", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "20", "20", "", "", "90.1", "82.3", "", "60.1", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "93.1", "99.0", "", "", "", "", "97.9"]} -{"pcdb_id": 16554, "brand_name": "Grant", "model_name": "Vortex 20G Outdoor Module", "model_qualifier": "", "winter_efficiency_pct": 90.1, "summer_efficiency_pct": 82.3, "comparative_hot_water_efficiency_pct": 60.1, "output_kw_max": 20.0, "final_year_of_manufacture": null, "raw": ["016554", "000048", "0", "2012/Mar/27 10:12", "Grant Engineering (UK)", "Grant", "Vortex 20G Outdoor Module", "", "", "2010", "current", "4", "1", "2", "1", "0", "", "", "2", "3", "2", "20", "20", "", "", "90.1", "82.3", "", "60.1", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "93.1", "99.0", "", "", "", "", "97.9"]} -{"pcdb_id": 16555, "brand_name": "Grant", "model_name": "Vortex 20G Outdoor Module System", "model_qualifier": "", "winter_efficiency_pct": 90.1, "summer_efficiency_pct": 82.3, "comparative_hot_water_efficiency_pct": 60.1, "output_kw_max": 20.0, "final_year_of_manufacture": null, "raw": ["016555", "000048", "0", "2012/Mar/27 10:12", "Grant Engineering (UK)", "Grant", "Vortex 20G Outdoor Module System", "", "", "2010", "current", "4", "1", "2", "1", "0", "", "", "2", "3", "2", "20", "20", "", "", "90.1", "82.3", "", "60.1", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "93.1", "99.0", "", "", "", "", "97.9"]} -{"pcdb_id": 16556, "brand_name": "Grant", "model_name": "Vortex 20G Boilerhouse", "model_qualifier": "", "winter_efficiency_pct": 90.1, "summer_efficiency_pct": 82.3, "comparative_hot_water_efficiency_pct": 60.1, "output_kw_max": 20.0, "final_year_of_manufacture": null, "raw": ["016556", "000048", "0", "2012/Mar/27 10:12", "Grant Engineering (UK)", "Grant", "Vortex 20G Boilerhouse", "", "", "2010", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "20", "20", "", "", "90.1", "82.3", "", "60.1", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "93.1", "99.0", "", "", "", "", "97.9"]} -{"pcdb_id": 16557, "brand_name": "Grant", "model_name": "Vortex 20G Boilerhouse System", "model_qualifier": "", "winter_efficiency_pct": 90.1, "summer_efficiency_pct": 82.3, "comparative_hot_water_efficiency_pct": 60.1, "output_kw_max": 20.0, "final_year_of_manufacture": null, "raw": ["016557", "000048", "0", "2012/Mar/27 10:12", "Grant Engineering (UK)", "Grant", "Vortex 20G Boilerhouse System", "", "", "2010", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "20", "20", "", "", "90.1", "82.3", "", "60.1", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "93.1", "99.0", "", "", "", "", "97.9"]} -{"pcdb_id": 16558, "brand_name": "Grant", "model_name": "Vortex 30G Utility System", "model_qualifier": "", "winter_efficiency_pct": 89.7, "summer_efficiency_pct": 81.9, "comparative_hot_water_efficiency_pct": 59.8, "output_kw_max": 30.0, "final_year_of_manufacture": null, "raw": ["016558", "000048", "0", "2012/Mar/27 10:12", "Grant Engineering (UK)", "Grant", "Vortex 30G Utility System", "", "", "2010", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "30", "30", "", "", "89.7", "81.9", "", "59.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "93.0", "98.3", "", "", "", "", "97.3"]} -{"pcdb_id": 16559, "brand_name": "Grant", "model_name": "Vortex 30G Outdoor Module", "model_qualifier": "", "winter_efficiency_pct": 89.7, "summer_efficiency_pct": 81.9, "comparative_hot_water_efficiency_pct": 59.8, "output_kw_max": 30.0, "final_year_of_manufacture": null, "raw": ["016559", "000048", "0", "2012/Mar/27 10:12", "Grant Engineering (UK)", "Grant", "Vortex 30G Outdoor Module", "", "", "2010", "current", "4", "1", "2", "1", "0", "", "", "2", "3", "2", "30", "30", "", "", "89.7", "81.9", "", "59.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "93.0", "98.3", "", "", "", "", "97.3"]} -{"pcdb_id": 16560, "brand_name": "Grant", "model_name": "Vortex 30G Outdoor Module System", "model_qualifier": "", "winter_efficiency_pct": 89.7, "summer_efficiency_pct": 81.9, "comparative_hot_water_efficiency_pct": 59.8, "output_kw_max": 30.0, "final_year_of_manufacture": null, "raw": ["016560", "000048", "0", "2012/Mar/27 10:12", "Grant Engineering (UK)", "Grant", "Vortex 30G Outdoor Module System", "", "", "2010", "current", "4", "1", "2", "1", "0", "", "", "2", "3", "2", "30", "30", "", "", "89.7", "81.9", "", "59.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "93.0", "98.3", "", "", "", "", "97.3"]} -{"pcdb_id": 16561, "brand_name": "Grant", "model_name": "Vortex 30G Boilerhouse", "model_qualifier": "", "winter_efficiency_pct": 89.7, "summer_efficiency_pct": 81.9, "comparative_hot_water_efficiency_pct": 59.8, "output_kw_max": 30.0, "final_year_of_manufacture": null, "raw": ["016561", "000048", "0", "2012/Mar/27 10:12", "Grant Engineering (UK)", "Grant", "Vortex 30G Boilerhouse", "", "", "2010", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "30", "30", "", "", "89.7", "81.9", "", "59.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "93.0", "98.3", "", "", "", "", "97.3"]} -{"pcdb_id": 16562, "brand_name": "Grant", "model_name": "Vortex 30G Boilerhouse System", "model_qualifier": "", "winter_efficiency_pct": 89.7, "summer_efficiency_pct": 81.9, "comparative_hot_water_efficiency_pct": 59.8, "output_kw_max": 30.0, "final_year_of_manufacture": null, "raw": ["016562", "000048", "0", "2012/Mar/27 10:12", "Grant Engineering (UK)", "Grant", "Vortex 30G Boilerhouse System", "", "", "2010", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "30", "30", "", "", "89.7", "81.9", "", "59.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "93.0", "98.3", "", "", "", "", "97.3"]} -{"pcdb_id": 16563, "brand_name": "Grant", "model_name": "Vortex 30G Utility", "model_qualifier": "", "winter_efficiency_pct": 89.7, "summer_efficiency_pct": 81.9, "comparative_hot_water_efficiency_pct": 59.8, "output_kw_max": 30.0, "final_year_of_manufacture": null, "raw": ["016563", "000048", "0", "2012/Mar/27 10:12", "Grant Engineering (UK)", "Grant", "Vortex 30G Utility", "", "", "2010", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "30", "30", "", "", "89.7", "81.9", "", "59.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "93.0", "98.3", "", "", "", "", "97.3"]} -{"pcdb_id": 16564, "brand_name": "Sime", "model_name": "Format DGT HE", "model_qualifier": "12 System", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 11.3, "final_year_of_manufacture": 2018, "raw": ["016564", "000213", "0", "2018/Feb/26 17:07", "Fonderie Sime S.p.A.", "Sime", "Format DGT HE", "12 System", "", "2009", "2018", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "11.3", "11.3", "", "", "88.5", "79.5", "", "58.0", "", "2", "", "", "102", "1", "2", "125", "8", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.5", "97.8", "", "", "", "", "96.0"]} -{"pcdb_id": 16565, "brand_name": "Sime", "model_name": "Format DGT HE", "model_qualifier": "12 System", "winter_efficiency_pct": 89.5, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 58.8, "output_kw_max": 11.3, "final_year_of_manufacture": 2018, "raw": ["016565", "000213", "0", "2018/Feb/26 17:08", "Fonderie Sime S.p.A.", "Sime", "Format DGT HE", "12 System", "", "2009", "2018", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "11.3", "11.3", "", "", "89.5", "80.5", "", "58.8", "", "2", "1", "", "102", "1", "2", "125", "8", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.4", "99.9", "", "", "", "", "98.1"]} -{"pcdb_id": 16566, "brand_name": "Remeha", "model_name": "Quinta Pro 65", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 61.0, "final_year_of_manufacture": null, "raw": ["016566", "000006", "0", "2012/Mar/27 10:12", "Broag Remeha", "Remeha", "Quinta Pro 65", "", "", "2010", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "61", "61", "", "", "88.6", "79.6", "", "58.2", "", "2", "", "", "102", "1", "2", "88", "6", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.6", "98.1", "", "", "", "", "96.3"]} -{"pcdb_id": 16567, "brand_name": "Remeha", "model_name": "Quinta Pro 45", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 40.0, "final_year_of_manufacture": null, "raw": ["016567", "000006", "0", "2012/Mar/27 10:12", "Broag Remeha", "Remeha", "Quinta Pro 45", "", "", "2010", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "40", "40", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "68", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.6", "97.0", "", "", "", "", "95.2"]} -{"pcdb_id": 16570, "brand_name": "Glow-worm", "model_name": "Betacom 24a", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 56.1, "output_kw_max": 18.0, "final_year_of_manufacture": 2013, "raw": ["016570", "000207", "0", "2013/Aug/23 09:29", "Glow-worm", "Glow-worm", "Betacom 24a", "", "GC No 47-019-13", "2010", "2013", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "18", "18", "", "", "88.4", "79.8", "", "56.1", "", "2", "", "", "104", "1", "2", "68", "6", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "97.8", "", "", "", "", "95.9"]} -{"pcdb_id": 16572, "brand_name": "Glow-worm", "model_name": "Betacom 24a", "model_qualifier": "", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 56.8, "output_kw_max": 18.0, "final_year_of_manufacture": null, "raw": ["016572", "000207", "0", "2013/Jan/30 14:28", "Vaillant Industrial UK", "Glow-worm", "Betacom 24a", "", "", "2010", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "18", "18", "", "", "89.4", "80.8", "", "56.8", "", "2", "1", "", "104", "1", "2", "68", "6", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.8", "99.9", "", "", "", "", "98.0"]} -{"pcdb_id": 16573, "brand_name": "Glow-worm", "model_name": "Betacom 28a", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 56.2, "output_kw_max": 24.5, "final_year_of_manufacture": 2013, "raw": ["016573", "000207", "0", "2013/Aug/23 09:29", "Vaillant", "Glow-worm", "Betacom 28a", "", "GC No 47-019-14", "2010", "2013", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.5", "24.5", "", "", "88.6", "80.0", "", "56.2", "", "2", "", "", "104", "1", "2", "68", "6", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "98.3", "", "", "", "", "96.3"]} -{"pcdb_id": 16574, "brand_name": "Glow-worm", "model_name": "Betacom 28a", "model_qualifier": "", "winter_efficiency_pct": 89.6, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 57.0, "output_kw_max": 24.5, "final_year_of_manufacture": null, "raw": ["016574", "000207", "0", "2013/Jan/30 14:29", "Vaillant Industrial UK", "Glow-worm", "Betacom 28a", "", "", "2010", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24.5", "24.5", "", "", "89.6", "81.0", "", "57.0", "", "2", "1", "", "104", "1", "2", "68", "6", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.9", "100.5", "", "", "", "", "98.5"]} -{"pcdb_id": 16575, "brand_name": "Mistral", "model_name": "Lo-Nox BF CKUT 1 15/20", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 59.2, "output_kw_max": 20.0, "final_year_of_manufacture": null, "raw": ["016575", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "Lo-Nox BF CKUT 1 15/20", "", "", "2010", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "15", "20", "", "", "88.8", "81.0", "", "59.2", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.9", "96.3", "", "", "", "", "95.5"]} -{"pcdb_id": 16576, "brand_name": "Mistral", "model_name": "Lo-Nox BF CKUT 2 20/27", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 59.2, "output_kw_max": 27.0, "final_year_of_manufacture": null, "raw": ["016576", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "Lo-Nox BF CKUT 2 20/27", "", "", "2010", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "20", "27", "", "", "88.8", "81.0", "", "59.2", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.9", "96.3", "", "", "", "", "95.5"]} -{"pcdb_id": 16577, "brand_name": "Mistral", "model_name": "Lo-Nox BF CKUT 3 27/35", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 59.2, "output_kw_max": 35.0, "final_year_of_manufacture": null, "raw": ["016577", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "Lo-Nox BF CKUT 3 27/35", "", "", "2010", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "27", "35", "", "", "88.8", "81.0", "", "59.2", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.9", "96.3", "", "", "", "", "95.5"]} -{"pcdb_id": 16578, "brand_name": "Mistral", "model_name": "Lo-Nox BF CKUT 4 35/42", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 59.2, "output_kw_max": 42.0, "final_year_of_manufacture": null, "raw": ["016578", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "Lo-Nox BF CKUT 4 35/42", "", "", "2010", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "35", "42", "", "", "88.8", "81.0", "", "59.2", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.9", "96.3", "", "", "", "", "95.5"]} -{"pcdb_id": 16579, "brand_name": "Mistral", "model_name": "Lo-Nox BF CS1 15/20", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 59.2, "output_kw_max": 20.0, "final_year_of_manufacture": null, "raw": ["016579", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "Lo-Nox BF CS1 15/20", "", "", "2010", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "15", "20", "", "", "88.8", "81.0", "", "59.2", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.9", "96.3", "", "", "", "", "95.5"]} -{"pcdb_id": 16580, "brand_name": "Mistral", "model_name": "Lo-Nox BF CS2 20/27", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 59.2, "output_kw_max": 27.0, "final_year_of_manufacture": null, "raw": ["016580", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "Lo-Nox BF CS2 20/27", "", "", "2010", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "20", "27", "", "", "88.8", "81.0", "", "59.2", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.9", "96.3", "", "", "", "", "95.5"]} -{"pcdb_id": 16581, "brand_name": "Mistral", "model_name": "Lo-Nox BF CS3 27/35", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 59.2, "output_kw_max": 35.0, "final_year_of_manufacture": null, "raw": ["016581", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "Lo-Nox BF CS3 27/35", "", "", "2010", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "27", "35", "", "", "88.8", "81.0", "", "59.2", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.9", "96.3", "", "", "", "", "95.5"]} -{"pcdb_id": 16582, "brand_name": "Mistral", "model_name": "Lo-Nox BF CS4 35/42", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 59.2, "output_kw_max": 42.0, "final_year_of_manufacture": null, "raw": ["016582", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "Lo-Nox BF CS4 35/42", "", "", "2010", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "35", "42", "", "", "88.8", "81.0", "", "59.2", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.9", "96.3", "", "", "", "", "95.5"]} -{"pcdb_id": 16584, "brand_name": "Mistral", "model_name": "Lo-Nox BF CBH 1 15/20", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 59.2, "output_kw_max": 20.0, "final_year_of_manufacture": null, "raw": ["016584", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "Lo-Nox BF CBH 1 15/20", "", "", "2010", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "15", "20", "", "", "88.8", "81.0", "", "59.2", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.9", "96.3", "", "", "", "", "95.5"]} -{"pcdb_id": 16585, "brand_name": "Mistral", "model_name": "Lo-Nox BF CBH 2 20/27", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 59.2, "output_kw_max": 27.0, "final_year_of_manufacture": null, "raw": ["016585", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "Lo-Nox BF CBH 2 20/27", "", "", "2010", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "20", "27", "", "", "88.8", "81.0", "", "59.2", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.9", "96.3", "", "", "", "", "95.5"]} -{"pcdb_id": 16586, "brand_name": "Mistral", "model_name": "Lo-Nox BF CBH 3 27/35", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 59.2, "output_kw_max": 35.0, "final_year_of_manufacture": null, "raw": ["016586", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "Lo-Nox BF CBH 3 27/35", "", "", "2010", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "27", "35", "", "", "88.8", "81.0", "", "59.2", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.9", "96.3", "", "", "", "", "95.5"]} -{"pcdb_id": 16587, "brand_name": "Mistral", "model_name": "Lo-Nox BF CBH 4 35/42", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 59.2, "output_kw_max": 42.0, "final_year_of_manufacture": null, "raw": ["016587", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "Lo-Nox BF CBH 4 35/42", "", "", "2010", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "35", "42", "", "", "88.8", "81.0", "", "59.2", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.9", "96.3", "", "", "", "", "95.5"]} -{"pcdb_id": 16588, "brand_name": "Mistral", "model_name": "Lo-Nox BF CC1 15/20", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 81.4, "comparative_hot_water_efficiency_pct": 57.2, "output_kw_max": 20.0, "final_year_of_manufacture": null, "raw": ["016588", "000056", "0", "2010/Nov/30 10:26", "Mistral Boilers", "Mistral", "Lo-Nox BF CC1 15/20", "", "", "2010", "current", "4", "1", "1", "2", "0", "", "", "2", "3", "1", "15", "20", "", "", "88.8", "81.4", "", "57.2", "", "2", "", "", "202", "1", "1", "", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.9", "96.3", "", "", "", "", "95.5"]} -{"pcdb_id": 16589, "brand_name": "Mistral", "model_name": "Lo-Nox BF CC2 20/27", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 81.4, "comparative_hot_water_efficiency_pct": 57.2, "output_kw_max": 27.0, "final_year_of_manufacture": null, "raw": ["016589", "000056", "0", "2010/Nov/30 10:26", "Mistral Boilers", "Mistral", "Lo-Nox BF CC2 20/27", "", "", "2010", "current", "4", "1", "1", "2", "0", "", "", "2", "3", "1", "20", "27", "", "", "88.8", "81.4", "", "57.2", "", "2", "", "", "202", "1", "1", "", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.9", "96.3", "", "", "", "", "95.5"]} -{"pcdb_id": 16590, "brand_name": "Mistral", "model_name": "Lo-Nox BF CC3 27/35", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 81.4, "comparative_hot_water_efficiency_pct": 57.2, "output_kw_max": 35.0, "final_year_of_manufacture": null, "raw": ["016590", "000056", "0", "2010/Nov/30 10:26", "Mistral Boilers", "Mistral", "Lo-Nox BF CC3 27/35", "", "", "2010", "current", "4", "1", "1", "2", "0", "", "", "2", "3", "1", "27", "35", "", "", "88.8", "81.4", "", "57.2", "", "2", "", "", "202", "1", "1", "", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.9", "96.3", "", "", "", "", "95.5"]} -{"pcdb_id": 16591, "brand_name": "Mistral", "model_name": "Lo-Nox BF CC4 35/42", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 81.4, "comparative_hot_water_efficiency_pct": 57.2, "output_kw_max": 42.0, "final_year_of_manufacture": null, "raw": ["016591", "000056", "0", "2010/Nov/30 10:26", "Mistral Boilers", "Mistral", "Lo-Nox BF CC4 35/42", "", "", "2010", "current", "4", "1", "1", "2", "0", "", "", "2", "3", "1", "35", "42", "", "", "88.8", "81.4", "", "57.2", "", "2", "", "", "202", "1", "1", "", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.9", "96.3", "", "", "", "", "95.5"]} -{"pcdb_id": 16592, "brand_name": "Mistral", "model_name": "Lo-Nox BF CC1 Plus 15/20", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 81.4, "comparative_hot_water_efficiency_pct": 57.2, "output_kw_max": 20.0, "final_year_of_manufacture": null, "raw": ["016592", "000056", "0", "2010/Nov/30 10:26", "Mistral Boilers", "Mistral", "Lo-Nox BF CC1 Plus 15/20", "", "", "2010", "current", "4", "1", "1", "2", "0", "", "", "2", "3", "1", "15", "20", "", "", "88.8", "81.4", "", "57.2", "", "2", "", "", "202", "1", "1", "", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.9", "96.3", "", "", "", "", "95.5"]} -{"pcdb_id": 16593, "brand_name": "Mistral", "model_name": "Lo-Nox BF CC2 Plus 20/27", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 81.4, "comparative_hot_water_efficiency_pct": 57.2, "output_kw_max": 27.0, "final_year_of_manufacture": null, "raw": ["016593", "000056", "0", "2010/Nov/30 10:26", "Mistral Boilers", "Mistral", "Lo-Nox BF CC2 Plus 20/27", "", "", "2010", "current", "4", "1", "1", "2", "0", "", "", "2", "3", "1", "20", "27", "", "", "88.8", "81.4", "", "57.2", "", "2", "", "", "202", "1", "1", "", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.9", "96.3", "", "", "", "", "95.5"]} -{"pcdb_id": 16594, "brand_name": "Mistral", "model_name": "Lo-Nox BF CC3 Plus 27/35", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 81.4, "comparative_hot_water_efficiency_pct": 57.2, "output_kw_max": 35.0, "final_year_of_manufacture": null, "raw": ["016594", "000056", "0", "2010/Nov/30 10:26", "Mistral Boilers", "Mistral", "Lo-Nox BF CC3 Plus 27/35", "", "", "2010", "current", "4", "1", "1", "2", "0", "", "", "2", "3", "1", "27", "35", "", "", "88.8", "81.4", "", "57.2", "", "2", "", "", "202", "1", "1", "", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.9", "96.3", "", "", "", "", "95.5"]} -{"pcdb_id": 16595, "brand_name": "Mistral", "model_name": "Lo-Nox BF CC4 Plus 35/42", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 81.4, "comparative_hot_water_efficiency_pct": 57.2, "output_kw_max": 42.0, "final_year_of_manufacture": null, "raw": ["016595", "000056", "0", "2010/Nov/30 10:26", "Mistral Boilers", "Mistral", "Lo-Nox BF CC4 Plus 35/42", "", "", "2010", "current", "4", "1", "1", "2", "0", "", "", "2", "3", "1", "35", "42", "", "", "88.8", "81.4", "", "57.2", "", "2", "", "", "202", "1", "1", "", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.9", "96.3", "", "", "", "", "95.5"]} -{"pcdb_id": 16596, "brand_name": "Mistral", "model_name": "Lo-Nox BF COD1 15/20", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 59.2, "output_kw_max": 20.0, "final_year_of_manufacture": null, "raw": ["016596", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "Lo-Nox BF COD1 15/20", "", "", "2010", "current", "4", "1", "2", "1", "0", "", "", "2", "3", "1", "15", "20", "", "", "88.8", "81.0", "", "59.2", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.9", "96.3", "", "", "", "", "95.5"]} -{"pcdb_id": 16597, "brand_name": "Mistral", "model_name": "Lo-Nox BF COD2 20/27", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 59.2, "output_kw_max": 27.0, "final_year_of_manufacture": null, "raw": ["016597", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "Lo-Nox BF COD2 20/27", "", "", "2010", "current", "4", "1", "2", "1", "0", "", "", "2", "3", "1", "20", "27", "", "", "88.8", "81.0", "", "59.2", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.9", "96.3", "", "", "", "", "95.5"]} -{"pcdb_id": 16598, "brand_name": "Mistral", "model_name": "Lo-Nox BF COD3 27/35", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 59.2, "output_kw_max": 35.0, "final_year_of_manufacture": null, "raw": ["016598", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "Lo-Nox BF COD3 27/35", "", "", "2010", "current", "4", "1", "2", "1", "0", "", "", "2", "3", "1", "27", "35", "", "", "88.8", "81.0", "", "59.2", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.9", "96.3", "", "", "", "", "95.5"]} -{"pcdb_id": 16599, "brand_name": "Mistral", "model_name": "Lo-Nox BF COD4 35/42", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 59.2, "output_kw_max": 42.0, "final_year_of_manufacture": null, "raw": ["016599", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "Lo-Nox BF COD4 35/42", "", "", "2010", "current", "4", "1", "2", "1", "0", "", "", "2", "3", "1", "35", "42", "", "", "88.8", "81.0", "", "59.2", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.9", "96.3", "", "", "", "", "95.5"]} -{"pcdb_id": 16600, "brand_name": "Mistral", "model_name": "Lo-Nox BF CODSS1 15/20", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 59.2, "output_kw_max": 20.0, "final_year_of_manufacture": null, "raw": ["016600", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "Lo-Nox BF CODSS1 15/20", "", "", "2010", "current", "4", "1", "2", "1", "0", "", "", "2", "3", "1", "15", "20", "", "", "88.8", "81.0", "", "59.2", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.9", "96.3", "", "", "", "", "95.5"]} -{"pcdb_id": 16601, "brand_name": "Mistral", "model_name": "Lo-Nox BF CODSS2 20/27", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 59.2, "output_kw_max": 27.0, "final_year_of_manufacture": null, "raw": ["016601", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "Lo-Nox BF CODSS2 20/27", "", "", "2010", "current", "4", "1", "2", "1", "0", "", "", "2", "3", "1", "20", "27", "", "", "88.8", "81.0", "", "59.2", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.9", "96.3", "", "", "", "", "95.5"]} -{"pcdb_id": 16602, "brand_name": "Mistral", "model_name": "Lo-Nox BF CODSS3 27/35", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 59.2, "output_kw_max": 35.0, "final_year_of_manufacture": null, "raw": ["016602", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "Lo-Nox BF CODSS3 27/35", "", "", "2010", "current", "4", "1", "2", "1", "0", "", "", "2", "3", "1", "27", "35", "", "", "88.8", "81.0", "", "59.2", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.9", "96.3", "", "", "", "", "95.5"]} -{"pcdb_id": 16603, "brand_name": "Mistral", "model_name": "Lo-Nox BF CODSS4 35/42", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 59.2, "output_kw_max": 42.0, "final_year_of_manufacture": null, "raw": ["016603", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "Lo-Nox BF CODSS4 35/42", "", "", "2010", "current", "4", "1", "2", "1", "0", "", "", "2", "3", "1", "35", "42", "", "", "88.8", "81.0", "", "59.2", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.9", "96.3", "", "", "", "", "95.5"]} -{"pcdb_id": 16604, "brand_name": "Mistral", "model_name": "Lo-Nox BF CODC1 15/20", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 81.4, "comparative_hot_water_efficiency_pct": 57.2, "output_kw_max": 20.0, "final_year_of_manufacture": null, "raw": ["016604", "000056", "0", "2010/Nov/30 10:27", "Mistral Boilers", "Mistral", "Lo-Nox BF CODC1 15/20", "", "", "2010", "current", "4", "1", "2", "2", "0", "", "", "2", "3", "1", "15", "20", "", "", "88.8", "81.4", "", "57.2", "", "2", "", "", "202", "1", "1", "", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.9", "96.3", "", "", "", "", "95.5"]} -{"pcdb_id": 16605, "brand_name": "Mistral", "model_name": "Lo-Nox BF CODC2 20/27", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 81.4, "comparative_hot_water_efficiency_pct": 57.2, "output_kw_max": 27.0, "final_year_of_manufacture": null, "raw": ["016605", "000056", "0", "2010/Nov/30 10:27", "Mistral Boilers", "Mistral", "Lo-Nox BF CODC2 20/27", "", "", "2010", "current", "4", "1", "2", "2", "0", "", "", "2", "3", "1", "20", "27", "", "", "88.8", "81.4", "", "57.2", "", "2", "", "", "202", "1", "1", "", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.9", "96.3", "", "", "", "", "95.5"]} -{"pcdb_id": 16606, "brand_name": "Mistral", "model_name": "Lo-Nox BF CODC3 Plus 27/35", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 81.4, "comparative_hot_water_efficiency_pct": 57.2, "output_kw_max": 35.0, "final_year_of_manufacture": null, "raw": ["016606", "000056", "0", "2010/Nov/30 10:27", "Mistral Boilers", "Mistral", "Lo-Nox BF CODC3 Plus 27/35", "", "", "2010", "current", "4", "1", "2", "2", "0", "", "", "2", "3", "1", "27", "35", "", "", "88.8", "81.4", "", "57.2", "", "2", "", "", "202", "1", "1", "", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.9", "96.3", "", "", "", "", "95.5"]} -{"pcdb_id": 16607, "brand_name": "Mistral", "model_name": "Lo-Nox BF CODC4 35/42", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 81.4, "comparative_hot_water_efficiency_pct": 57.2, "output_kw_max": 42.0, "final_year_of_manufacture": null, "raw": ["016607", "000056", "0", "2010/Nov/30 10:27", "Mistral Boilers", "Mistral", "Lo-Nox BF CODC4 35/42", "", "", "2010", "current", "4", "1", "2", "2", "0", "", "", "2", "3", "1", "35", "42", "", "", "88.8", "81.4", "", "57.2", "", "2", "", "", "202", "1", "1", "", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.9", "96.3", "", "", "", "", "95.5"]} -{"pcdb_id": 16608, "brand_name": "Mistral", "model_name": "Lo-Nox BF CODC1 Plus 15/20", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 81.4, "comparative_hot_water_efficiency_pct": 57.2, "output_kw_max": 20.0, "final_year_of_manufacture": null, "raw": ["016608", "000056", "0", "2010/Nov/30 10:27", "Mistral Boilers", "Mistral", "Lo-Nox BF CODC1 Plus 15/20", "", "", "2010", "current", "4", "1", "2", "2", "0", "", "", "2", "3", "1", "15", "20", "", "", "88.8", "81.4", "", "57.2", "", "2", "", "", "202", "1", "1", "", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.9", "96.3", "", "", "", "", "95.5"]} -{"pcdb_id": 16609, "brand_name": "Mistral", "model_name": "Lo-Nox BF CODC2 Plus 20/27", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 81.4, "comparative_hot_water_efficiency_pct": 57.2, "output_kw_max": 27.0, "final_year_of_manufacture": null, "raw": ["016609", "000056", "0", "2010/Nov/30 10:27", "Mistral Boilers", "Mistral", "Lo-Nox BF CODC2 Plus 20/27", "", "", "2010", "current", "4", "1", "2", "2", "0", "", "", "2", "3", "1", "20", "27", "", "", "88.8", "81.4", "", "57.2", "", "2", "", "", "202", "1", "1", "", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.9", "96.3", "", "", "", "", "95.5"]} -{"pcdb_id": 16610, "brand_name": "Mistral", "model_name": "Lo-Nox BF CODC3 27/35", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 81.4, "comparative_hot_water_efficiency_pct": 57.2, "output_kw_max": 35.0, "final_year_of_manufacture": null, "raw": ["016610", "000056", "0", "2010/Nov/30 10:27", "Mistral Boilers", "Mistral", "Lo-Nox BF CODC3 27/35", "", "", "2010", "current", "4", "1", "2", "2", "0", "", "", "2", "3", "1", "27", "35", "", "", "88.8", "81.4", "", "57.2", "", "2", "", "", "202", "1", "1", "", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.9", "96.3", "", "", "", "", "95.5"]} -{"pcdb_id": 16611, "brand_name": "Mistral", "model_name": "Lo-Nox BF CODC4 Plus 35/42", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 81.4, "comparative_hot_water_efficiency_pct": 57.2, "output_kw_max": 42.0, "final_year_of_manufacture": null, "raw": ["016611", "000056", "0", "2010/Nov/30 10:27", "Mistral Boilers", "Mistral", "Lo-Nox BF CODC4 Plus 35/42", "", "", "2010", "current", "4", "1", "2", "2", "0", "", "", "2", "3", "1", "35", "42", "", "", "88.8", "81.4", "", "57.2", "", "2", "", "", "202", "1", "1", "", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.9", "96.3", "", "", "", "", "95.5"]} -{"pcdb_id": 16612, "brand_name": "Ravenheat", "model_name": "Combiplus 32", "model_qualifier": "Natural Gas", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 87.1, "comparative_hot_water_efficiency_pct": 81.2, "output_kw_max": 25.74, "final_year_of_manufacture": null, "raw": ["016612", "000026", "0", "2011/Mar/25 16:31", "Ravenheat", "Ravenheat", "Combiplus 32", "Natural Gas", "", "2009", "current", "1", "2", "1", "2", "1", "", "", "2", "2", "2", "25.74", "25.74", "", "", "88.8", "87.1", "", "81.2", "", "2", "", "", "104", "1", "2", "160", "0", "0", "", "", "", "0", "", "", "", "", "1", "6.4894", "0.2674", "0.0057", "0.39333", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.2", "98.4", "", "", "", "", "96.6"]} -{"pcdb_id": 16613, "brand_name": "Ravenheat", "model_name": "Combiplus 32", "model_qualifier": "LPG", "winter_efficiency_pct": 89.8, "summer_efficiency_pct": 81.2, "comparative_hot_water_efficiency_pct": 57.1, "output_kw_max": 25.74, "final_year_of_manufacture": null, "raw": ["016613", "000026", "0", "2013/Apr/08 09:36", "Ravenheat", "Ravenheat", "Combiplus 32", "LPG", "", "2009", "current", "2", "2", "1", "2", "1", "", "", "2", "2", "2", "25.74", "25.74", "", "", "89.8", "81.2", "", "57.1", "", "2", "1", "", "104", "1", "2", "160", "0", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "91.2", "100.6", "", "", "", "", "98.8"]} -{"pcdb_id": 16614, "brand_name": "Ravenheat", "model_name": "Combiplus 32 (T)", "model_qualifier": "Natural Gas", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 87.1, "comparative_hot_water_efficiency_pct": 81.2, "output_kw_max": 25.74, "final_year_of_manufacture": null, "raw": ["016614", "000026", "0", "2011/Mar/25 16:32", "Ravenheat", "Ravenheat", "Combiplus 32 (T)", "Natural Gas", "", "2009", "current", "1", "2", "1", "2", "1", "", "", "2", "2", "2", "25.74", "25.74", "", "", "88.8", "87.1", "", "81.2", "", "2", "", "", "104", "1", "2", "160", "0", "0", "", "", "", "0", "", "", "", "", "1", "6.4894", "0.2674", "0.0057", "0.39333", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.2", "98.4", "", "", "", "", "96.6"]} -{"pcdb_id": 16615, "brand_name": "Ravenheat", "model_name": "Combiplus 32 (T)", "model_qualifier": "LPG", "winter_efficiency_pct": 89.8, "summer_efficiency_pct": 81.2, "comparative_hot_water_efficiency_pct": 57.1, "output_kw_max": 25.74, "final_year_of_manufacture": null, "raw": ["016615", "000026", "0", "2013/Apr/08 09:39", "Ravenheat", "Ravenheat", "Combiplus 32 (T)", "LPG", "", "2009", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "25.74", "25.74", "", "", "89.8", "81.2", "", "57.1", "", "2", "1", "", "104", "1", "2", "160", "0", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "91.2", "100.6", "", "", "", "", "98.8"]} -{"pcdb_id": 16616, "brand_name": "Ravenheat", "model_name": "Combistore 32", "model_qualifier": "Natural Gas", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 87.1, "comparative_hot_water_efficiency_pct": 82.5, "output_kw_max": 25.74, "final_year_of_manufacture": null, "raw": ["016616", "000026", "0", "2011/Mar/25 16:32", "Ravenheat", "Ravenheat", "Combistore 32", "Natural Gas", "", "2009", "current", "1", "2", "1", "2", "1", "", "", "2", "2", "2", "25.74", "25.74", "", "", "88.8", "87.1", "", "82.5", "", "2", "", "", "104", "1", "2", "160", "0", "0", "", "", "", "0", "", "", "", "", "1", "6.3819", "0.2665", "0.0064", "0.28564", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.2", "98.4", "", "", "", "", "96.6"]} -{"pcdb_id": 16617, "brand_name": "Ravenheat", "model_name": "Combistore 32", "model_qualifier": "LPG", "winter_efficiency_pct": 89.8, "summer_efficiency_pct": 81.2, "comparative_hot_water_efficiency_pct": 57.1, "output_kw_max": 25.74, "final_year_of_manufacture": null, "raw": ["016617", "000026", "0", "2013/Apr/08 09:39", "Ravenheat", "Ravenheat", "Combistore 32", "LPG", "", "2009", "current", "2", "2", "1", "2", "1", "", "", "2", "2", "2", "25.74", "25.74", "", "", "89.8", "81.2", "", "57.1", "", "2", "1", "", "104", "1", "2", "160", "0", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "91.2", "100.6", "", "", "", "", "98.8"]} -{"pcdb_id": 16618, "brand_name": "Ravenheat", "model_name": "Combistore 32 (T)", "model_qualifier": "Natural Gas", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 87.1, "comparative_hot_water_efficiency_pct": 82.5, "output_kw_max": 25.74, "final_year_of_manufacture": null, "raw": ["016618", "000026", "0", "2011/Mar/25 16:33", "Ravenheat", "Ravenheat", "Combistore 32 (T)", "Natural Gas", "", "2009", "current", "1", "2", "1", "2", "1", "", "", "2", "2", "2", "25.74", "25.74", "", "", "88.8", "87.1", "", "82.5", "", "2", "", "", "104", "1", "2", "160", "0", "0", "", "", "", "0", "", "", "", "", "1", "6.3819", "0.2665", "0.0064", "0.28564", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.2", "98.4", "", "", "", "", "96.6"]} -{"pcdb_id": 16619, "brand_name": "Ravenheat", "model_name": "Combistore 32 (T)", "model_qualifier": "LPG", "winter_efficiency_pct": 89.8, "summer_efficiency_pct": 81.2, "comparative_hot_water_efficiency_pct": 57.1, "output_kw_max": 25.74, "final_year_of_manufacture": null, "raw": ["016619", "000026", "0", "2013/Apr/08 09:42", "Ravenheat", "Ravenheat", "Combistore 32 (T)", "LPG", "", "2009", "current", "2", "2", "1", "2", "1", "", "", "2", "2", "2", "25.74", "25.74", "", "", "89.8", "81.2", "", "57.1", "", "2", "1", "", "104", "1", "2", "160", "0", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "91.2", "100.6", "", "", "", "", "98.8"]} -{"pcdb_id": 16620, "brand_name": "Firebird", "model_name": "Silver System", "model_qualifier": "C20kW", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 80.7, "comparative_hot_water_efficiency_pct": 58.9, "output_kw_max": 20.0, "final_year_of_manufacture": 2017, "raw": ["016620", "000047", "0", "2018/Jan/03 11:52", "Firebird Boilers", "Firebird", "Silver System", "C20kW", "", "2010", "2017", "4", "1", "1", "1", "0", "", "", "2", "2", "1", "15", "20", "", "", "88.5", "80.7", "", "58.9", "", "2", "", "", "201", "1", "1", "38", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "92.2", "95.4", "", "", "", "", "94.8"]} -{"pcdb_id": 16621, "brand_name": "Firebird", "model_name": "Silver System", "model_qualifier": "C26kW", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 80.6, "comparative_hot_water_efficiency_pct": 58.9, "output_kw_max": 26.0, "final_year_of_manufacture": 2017, "raw": ["016621", "000047", "0", "2018/Jan/03 11:55", "Firebird Boilers", "Firebird", "Silver System", "C26kW", "", "2010", "2017", "4", "1", "1", "1", "0", "", "", "2", "2", "1", "20", "26", "", "", "88.4", "80.6", "", "58.9", "", "2", "", "", "201", "1", "1", "38", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.8", "95.5", "", "", "", "", "94.8"]} -{"pcdb_id": 16622, "brand_name": "Firebird", "model_name": "Silver System", "model_qualifier": "C35kW", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 35.0, "final_year_of_manufacture": 2017, "raw": ["016622", "000047", "0", "2018/Jan/03 11:56", "Firebird Boilers", "Firebird", "Silver System", "C35kW", "", "2010", "2017", "4", "1", "1", "1", "0", "", "", "2", "2", "1", "26", "35", "", "", "87.9", "80.1", "", "58.5", "", "2", "", "", "201", "1", "1", "38", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.5", "94.4", "", "", "", "", "93.8"]} -{"pcdb_id": 16623, "brand_name": "Firebird", "model_name": "Silver Utility", "model_qualifier": "C20kW", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 80.7, "comparative_hot_water_efficiency_pct": 58.9, "output_kw_max": 20.0, "final_year_of_manufacture": null, "raw": ["016623", "000047", "0", "2012/Mar/27 10:12", "Firebird Boilers", "Firebird", "Silver Utility", "C20kW", "", "2010", "current", "4", "1", "1", "1", "0", "", "", "2", "2", "1", "15", "20", "", "", "88.5", "80.7", "", "58.9", "", "2", "", "", "201", "1", "1", "38", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "92.2", "95.4", "", "", "", "", "94.8"]} -{"pcdb_id": 16624, "brand_name": "Firebird", "model_name": "Silver Utility", "model_qualifier": "C26kW", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 80.6, "comparative_hot_water_efficiency_pct": 58.9, "output_kw_max": 26.0, "final_year_of_manufacture": null, "raw": ["016624", "000047", "0", "2012/Mar/27 10:12", "Firebird Boilers", "Firebird", "Silver Utility", "C26kW", "", "2010", "current", "4", "1", "1", "1", "0", "", "", "2", "2", "1", "20", "26", "", "", "88.4", "80.6", "", "58.9", "", "2", "", "", "201", "1", "1", "38", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.8", "95.5", "", "", "", "", "94.8"]} -{"pcdb_id": 16625, "brand_name": "Firebird", "model_name": "Silver Utility", "model_qualifier": "C35kW", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 35.0, "final_year_of_manufacture": null, "raw": ["016625", "000047", "0", "2012/Mar/27 10:12", "Firebird Boilers", "Firebird", "Silver Utility", "C35kW", "", "2010", "current", "4", "1", "1", "1", "0", "", "", "2", "2", "1", "26", "35", "", "", "87.9", "80.1", "", "58.5", "", "2", "", "", "201", "1", "1", "38", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.5", "94.4", "", "", "", "", "93.8"]} -{"pcdb_id": 16626, "brand_name": "Firebird", "model_name": "Silver Boiilerhouse", "model_qualifier": "C20kW", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 80.7, "comparative_hot_water_efficiency_pct": 58.9, "output_kw_max": 20.0, "final_year_of_manufacture": null, "raw": ["016626", "000047", "0", "2012/Mar/27 10:12", "Firebird Boilers", "Firebird", "Silver Boiilerhouse", "C20kW", "", "2010", "current", "4", "1", "2", "1", "0", "", "", "2", "2", "1", "15", "20", "", "", "88.5", "80.7", "", "58.9", "", "2", "", "", "201", "1", "1", "38", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "92.2", "95.4", "", "", "", "", "94.8"]} -{"pcdb_id": 16627, "brand_name": "Firebird", "model_name": "Silver Boilerhouse", "model_qualifier": "C26kW", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 80.6, "comparative_hot_water_efficiency_pct": 58.9, "output_kw_max": 26.0, "final_year_of_manufacture": null, "raw": ["016627", "000047", "0", "2015/Nov/13 11:01", "Firebird Boilers", "Firebird", "Silver Boilerhouse", "C26kW", "", "2010", "current", "4", "1", "2", "1", "0", "", "", "2", "2", "1", "20", "26", "", "", "88.4", "80.6", "", "58.9", "", "2", "", "", "201", "1", "1", "38", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.8", "95.5", "", "", "", "", "94.8"]} -{"pcdb_id": 16628, "brand_name": "Firebird", "model_name": "Silver Boiilerhouse", "model_qualifier": "C35KW", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 35.0, "final_year_of_manufacture": null, "raw": ["016628", "000047", "0", "2012/Mar/27 10:12", "Firebird Boilers", "Firebird", "Silver Boiilerhouse", "C35KW", "", "2010", "current", "4", "1", "2", "1", "0", "", "", "2", "2", "1", "26", "35", "", "", "87.9", "80.1", "", "58.5", "", "2", "", "", "201", "1", "1", "38", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.5", "94.4", "", "", "", "", "93.8"]} -{"pcdb_id": 16629, "brand_name": "Firebird", "model_name": "Silverpac", "model_qualifier": "C20kW", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 80.7, "comparative_hot_water_efficiency_pct": 58.9, "output_kw_max": 20.0, "final_year_of_manufacture": null, "raw": ["016629", "000047", "0", "2012/Mar/27 10:12", "Firebird Boilers", "Firebird", "Silverpac", "C20kW", "", "2010", "current", "4", "1", "2", "1", "0", "", "", "2", "2", "1", "15", "20", "", "", "88.5", "80.7", "", "58.9", "", "2", "", "", "201", "1", "1", "38", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "92.2", "95.4", "", "", "", "", "94.8"]} -{"pcdb_id": 16630, "brand_name": "Firebird", "model_name": "Silverpac", "model_qualifier": "C26kW", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 80.6, "comparative_hot_water_efficiency_pct": 58.9, "output_kw_max": 26.0, "final_year_of_manufacture": null, "raw": ["016630", "000047", "0", "2012/Mar/27 10:12", "Firebird Boilers", "Firebird", "Silverpac", "C26kW", "", "2010", "current", "4", "1", "2", "1", "0", "", "", "2", "2", "1", "20", "26", "", "", "88.4", "80.6", "", "58.9", "", "2", "", "", "201", "1", "1", "38", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.8", "95.5", "", "", "", "", "94.8"]} -{"pcdb_id": 16631, "brand_name": "Firebird", "model_name": "Silverpac", "model_qualifier": "C35kW", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 35.0, "final_year_of_manufacture": null, "raw": ["016631", "000047", "0", "2012/Mar/27 10:12", "Firebird Boilers", "Firebird", "Silverpac", "C35kW", "", "2010", "current", "4", "1", "2", "1", "0", "", "", "2", "2", "1", "26", "35", "", "", "87.9", "80.1", "", "58.5", "", "2", "", "", "201", "1", "1", "38", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.5", "94.4", "", "", "", "", "93.8"]} -{"pcdb_id": 16632, "brand_name": "i-mini", "model_name": "24", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 62.3, "output_kw_max": 24.2, "final_year_of_manufacture": 2016, "raw": ["016632", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "i-mini", "24", "", "47-348-77", "2011", "2016", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "88.4", "79.8", "", "62.3", "", "2", "", "", "104", "1", "2", "146", "1", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "", "0035", "", "", "", "", "", "", "", "", "89.8", "96.9", "", "", "", "", "95.6"]} -{"pcdb_id": 16633, "brand_name": "i-mini", "model_name": "30", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 62.3, "output_kw_max": 24.2, "final_year_of_manufacture": 2016, "raw": ["016633", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "i-mini", "30", "", "47-348-78", "2011", "2016", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "88.4", "79.8", "", "62.3", "", "2", "", "", "104", "1", "2", "152", "1", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "", "0035", "", "", "", "", "", "", "", "", "90.0", "96.9", "", "", "", "", "95.6"]} -{"pcdb_id": 16634, "brand_name": "Ideal", "model_name": "Logic Code Combi", "model_qualifier": "26", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 75.1, "output_kw_max": 24.2, "final_year_of_manufacture": 2013, "raw": ["016634", "000008", "3", "2021/Nov/29 20:19", "Ideal Boilers", "Ideal", "Logic Code Combi", "26", "47-348-74", "2011", "2013", "1", "2", "1", "2", "1", "313", "060024", "2", "2", "2", "24.2", "24.2", "", "", "88.4", "87.3", "", "75.1", "", "2", "", "", "104", "1", "2", "146", "1", "0", "", "", "0", "0", "", "", "", "", "1", "7.0133", "0.1547", "0.0048", "0.92126", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.8", "96.9", "", "", "", "", "95.6"]} -{"pcdb_id": 16635, "brand_name": "Ideal", "model_name": "Logic Code Combi", "model_qualifier": "33", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 75.8, "output_kw_max": 24.2, "final_year_of_manufacture": 2013, "raw": ["016635", "000008", "3", "2021/Nov/29 20:19", "Ideal Boilers", "Ideal", "Logic Code Combi", "33", "47-348-75", "2011", "2013", "1", "2", "1", "2", "1", "313", "060025", "2", "2", "2", "24.2", "24.2", "", "", "88.4", "87.3", "", "75.8", "", "2", "", "", "104", "1", "2", "152", "1", "0", "", "", "0", "0", "", "", "", "", "1", "6.9512", "0.1528", "0.0045", "0.86711", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.0", "96.9", "", "", "", "", "95.6"]} -{"pcdb_id": 16636, "brand_name": "Ideal", "model_name": "Logic Code Combi", "model_qualifier": "38", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 75.8, "output_kw_max": 24.2, "final_year_of_manufacture": 2013, "raw": ["016636", "000008", "3", "2021/Nov/29 20:19", "Ideal Boilers", "Ideal", "Logic Code Combi", "38", "47-348-76", "2011", "2013", "1", "2", "1", "2", "1", "313", "060026", "2", "2", "2", "24.2", "24.2", "", "", "88.3", "87.3", "", "75.8", "", "2", "", "", "104", "1", "2", "177", "1", "0", "", "", "0", "0", "", "", "", "", "1", "6.9449", "0.1539", "0.0082", "0.83483", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.8", "96.9", "", "", "", "", "95.5"]} -{"pcdb_id": 16637, "brand_name": "Vokera", "model_name": "Compact", "model_qualifier": "25", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 86.6, "comparative_hot_water_efficiency_pct": 72.0, "output_kw_max": 19.5, "final_year_of_manufacture": null, "raw": ["016637", "000011", "0", "2012/Sep/19 14:28", "Vokera", "Vokera", "Compact", "25", "4736401", "2010", "current", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "19.5", "19.5", "", "", "88.4", "86.6", "", "72.0", "", "2", "", "", "104", "1", "2", "123", "4.5", "0", "", "", "0", "0", "", "", "", "", "1", "7.315", "0.105", "0.003", "1.17113", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "97.8", "", "", "", "", "95.9"]} -{"pcdb_id": 16638, "brand_name": "Glow-worm", "model_name": "Ultracom 2 35 Store", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 86.8, "comparative_hot_water_efficiency_pct": 59.2, "output_kw_max": 30.0, "final_year_of_manufacture": null, "raw": ["016638", "000207", "0", "2014/May/02 14:44", "Glow-worm", "Glow-worm", "Ultracom 2 35 Store", "", "GC No 47-019-15", "2011", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "30", "30", "", "", "88.4", "86.8", "", "59.2", "", "2", "", "", "106", "1", "2", "68", "7.1", "2", "", "0", "40", "0", "7", "2", "60", "", "1", "8.89", "0.263", "0.0009", "2.70975", "", "", "", "", "", "", "", "", "0085", "", "", "", "", "", "", "", "", "88.2", "97.8", "", "", "", "", "96.0"]} -{"pcdb_id": 16639, "brand_name": "Glow-worm", "model_name": "Ultracom 2 35 Store", "model_qualifier": "", "winter_efficiency_pct": 89.5, "summer_efficiency_pct": 82.2, "comparative_hot_water_efficiency_pct": 35.5, "output_kw_max": 30.0, "final_year_of_manufacture": null, "raw": ["016639", "000207", "0", "2024/Jan/31 10:17", "Glow-worm", "Glow-worm", "Ultracom 2 35 Store", "", "", "2011", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "30", "30", "", "", "89.5", "82.2", "", "35.5", "", "2", "1", "", "106", "1", "2", "68", "7.1", "2", "", "0", "40", "0", "7", "2", "60", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.2", "100.0", "", "", "", "", "98.1"]} -{"pcdb_id": 16640, "brand_name": "Remeha", "model_name": "Quinta Pro 30", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 32.0, "final_year_of_manufacture": null, "raw": ["016640", "000006", "0", "2012/Mar/27 10:12", "Broag Remeha", "Remeha", "Quinta Pro 30", "", "", "2010", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "32", "32", "", "", "88.1", "79.1", "", "57.8", "", "2", "", "", "102", "1", "2", "39", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "97.0", "", "", "", "", "95.3"]} -{"pcdb_id": 16642, "brand_name": "Heatline", "model_name": "CaprizPlus", "model_qualifier": "28", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 56.0, "output_kw_max": 23.4, "final_year_of_manufacture": null, "raw": ["016642", "000215", "0", "2011/Feb/22 12:50", "Heatline", "Heatline", "CaprizPlus", "28", "GCN 47-157-20", "2001", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "23.4", "23.4", "", "", "88.2", "79.6", "", "56.0", "", "2", "", "", "104", "1", "2", "130", "3", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "97.3", "", "", "", "", "95.5"]} -{"pcdb_id": 16643, "brand_name": "Heatline", "model_name": "CaprizPlus", "model_qualifier": "24", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 56.0, "output_kw_max": 17.6, "final_year_of_manufacture": null, "raw": ["016643", "000215", "0", "2011/Feb/22 12:50", "Heatline", "Heatline", "CaprizPlus", "24", "GCN 47-157-19", "2011", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "17.6", "17.6", "", "", "88.3", "79.7", "", "56.0", "", "2", "", "", "104", "1", "2", "130", "3", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "97.6", "", "", "", "", "95.7"]} -{"pcdb_id": 16644, "brand_name": "Heatline", "model_name": "Monza", "model_qualifier": "28", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 56.0, "output_kw_max": 23.4, "final_year_of_manufacture": null, "raw": ["016644", "000215", "0", "2011/Feb/22 12:50", "Heatline", "Heatline", "Monza", "28", "GCN 47-157-22", "2011", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "23.4", "23.4", "", "", "88.2", "79.6", "", "56.0", "", "2", "", "", "104", "1", "2", "130", "3", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "97.3", "", "", "", "", "95.5"]} -{"pcdb_id": 16645, "brand_name": "Heatline", "model_name": "Monza", "model_qualifier": "24", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 56.0, "output_kw_max": 17.6, "final_year_of_manufacture": null, "raw": ["016645", "000215", "0", "2011/Feb/22 12:51", "Heatline", "Heatline", "Monza", "24", "GCN 47-157-21", "2011", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "17.6", "17.6", "", "", "88.3", "79.7", "", "56.0", "", "2", "", "", "104", "1", "2", "130", "3", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "97.6", "", "", "", "", "95.7"]} -{"pcdb_id": 16646, "brand_name": "Vokera", "model_name": "Linea", "model_qualifier": "One", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 56.3, "output_kw_max": 29.34, "final_year_of_manufacture": null, "raw": ["016646", "000011", "0", "2014/Oct/15 11:21", "Vokera", "Vokera", "Linea", "One", "4736403", "2010", "current", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "29.34", "29.34", "", "", "88.6", "80.0", "", "56.3", "", "2", "", "", "104", "1", "2", "153", "4.5", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "", "", "", "", "88.1", "98.3", "", "", "", "", "96.4"]} -{"pcdb_id": 16647, "brand_name": "Vokera", "model_name": "Compact", "model_qualifier": "29", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 86.7, "comparative_hot_water_efficiency_pct": 71.9, "output_kw_max": 24.4, "final_year_of_manufacture": null, "raw": ["016647", "000011", "0", "2012/Sep/27 08:46", "Vokera", "Vokera", "Compact", "29", "4736402", "2010", "current", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "24.4", "24.4", "", "", "88.3", "86.7", "", "71.9", "", "2", "", "", "104", "1", "2", "128", "4.5", "0", "", "", "", "0", "", "", "", "", "1", "7.325", "0.103", "0.003", "1.18314", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "97.6", "", "", "", "", "95.7"]} -{"pcdb_id": 16648, "brand_name": "Ferroli", "model_name": "DOMIcondens HE", "model_qualifier": "26C", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 86.6, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 24.4, "final_year_of_manufacture": 2017, "raw": ["016648", "000097", "0", "2017/Aug/07 17:02", "Ferroli", "Ferroli", "DOMIcondens HE", "26C", "", "2011", "2017", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.4", "24.4", "", "", "87.9", "86.6", "", "57.8", "", "2", "", "", "104", "1", "2", "135", "2.0", "0", "", "", "", "0", "", "", "", "", "1", "9.1075", "0.0699", "0.0049", "2.8838", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "96.5", "", "", "", "", "94.9"]} -{"pcdb_id": 16649, "brand_name": "Ferroli", "model_name": "DOMIcondens HE", "model_qualifier": "26C", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 56.4, "output_kw_max": 24.4, "final_year_of_manufacture": 2017, "raw": ["016649", "000097", "0", "2017/Aug/21 13:40", "Ferroli", "Ferroli", "DOMIcondens HE", "26C", "", "2011", "2017", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24.4", "24.4", "", "", "88.9", "80.3", "", "56.4", "", "2", "1", "", "104", "1", "2", "135", "2.0", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.8", "98.6", "", "", "", "", "97.0"]} -{"pcdb_id": 16650, "brand_name": "Vokera", "model_name": "Unica", "model_qualifier": "36HE", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 55.9, "output_kw_max": 29.31, "final_year_of_manufacture": null, "raw": ["016650", "000011", "0", "2011/Mar/24 12:36", "Vokera", "Vokera", "Unica", "36HE", "4709487", "2006", "current", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "29.31", "29.31", "", "", "88.1", "79.5", "", "55.9", "", "2", "", "", "104", "1", "2", "150", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "97.1", "", "", "", "", "95.4"]} -{"pcdb_id": 16651, "brand_name": "GEM", "model_name": "E-Compact 50/70", "model_qualifier": "Cosyman", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 81.4, "comparative_hot_water_efficiency_pct": 59.5, "output_kw_max": 22.3, "final_year_of_manufacture": null, "raw": ["016651", "000260", "0", "2012/Mar/27 10:12", "GEM Heating Products", "GEM", "E-Compact 50/70", "Cosyman", "", "2007", "current", "4", "1", "2", "1", "0", "", "", "2", "3", "2", "15", "22.3", "", "", "89.2", "81.4", "", "59.5", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.3", "97.7", "", "", "", "", "96.5"]} -{"pcdb_id": 16652, "brand_name": "GEM", "model_name": "E-Compact 50/70", "model_qualifier": "Boiler House", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 81.4, "comparative_hot_water_efficiency_pct": 59.5, "output_kw_max": 22.3, "final_year_of_manufacture": null, "raw": ["016652", "000260", "0", "2012/Mar/27 10:12", "GEM Heating Products", "GEM", "E-Compact 50/70", "Boiler House", "", "2007", "current", "4", "1", "2", "1", "0", "", "", "2", "3", "2", "15", "22.3", "", "", "89.2", "81.4", "", "59.5", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.3", "97.7", "", "", "", "", "96.5"]} -{"pcdb_id": 16653, "brand_name": "GEM", "model_name": "E-Compact 70/90", "model_qualifier": "Boiler House", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 59.2, "output_kw_max": 27.9, "final_year_of_manufacture": null, "raw": ["016653", "000260", "0", "2012/Mar/27 10:12", "GEM Heating Products", "GEM", "E-Compact 70/90", "Boiler House", "", "2007", "current", "4", "1", "2", "1", "0", "", "", "2", "3", "2", "20", "27.9", "", "", "88.8", "81.0", "", "59.2", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "89.5", "97.4", "", "", "", "", "95.9"]} -{"pcdb_id": 16654, "brand_name": "GEM", "model_name": "E-Compact 70/90", "model_qualifier": "Cosyman", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 59.2, "output_kw_max": 27.9, "final_year_of_manufacture": null, "raw": ["016654", "000260", "0", "2012/Mar/27 10:12", "GEM Heating Products", "GEM", "E-Compact 70/90", "Cosyman", "", "2007", "current", "4", "1", "2", "1", "0", "", "", "2", "3", "2", "20", "27.9", "", "", "88.8", "81.0", "", "59.2", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "89.5", "97.4", "", "", "", "", "95.9"]} -{"pcdb_id": 16655, "brand_name": "Alpha", "model_name": "InTec 28S", "model_qualifier": "", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 28.0, "final_year_of_manufacture": null, "raw": ["016655", "000001", "0", "2013/May/24 12:32", "Alpha Therm", "Alpha", "InTec 28S", "", "", "2011", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "28", "28", "", "", "88.2", "79.2", "", "57.8", "", "2", "", "", "102", "1", "2", "125", "6", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.8", "96.9", "", "", "", "", "95.3"]} -{"pcdb_id": 16656, "brand_name": "Alpha", "model_name": "InTec 28S", "model_qualifier": "", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 28.0, "final_year_of_manufacture": null, "raw": ["016656", "000001", "0", "2013/Mar/28 08:26", "Alpha Therm", "Alpha", "InTec 28S", "", "", "2011", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "28", "28", "", "", "89.2", "80.2", "", "58.6", "", "2", "1", "", "102", "1", "2", "125", "6", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.8", "99.0", "", "", "", "", "97.5"]} -{"pcdb_id": 16657, "brand_name": "Alpha", "model_name": "InTec 18S", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 18.3, "final_year_of_manufacture": null, "raw": ["016657", "000001", "0", "2013/Mar/28 08:26", "Alpha Therm", "Alpha", "InTec 18S", "", "", "2011", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18.3", "18.3", "", "", "88.6", "79.6", "", "58.1", "", "2", "", "", "102", "1", "2", "115", "6", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.5", "98.1", "", "", "", "", "96.3"]} -{"pcdb_id": 16658, "brand_name": "Alpha", "model_name": "InTec 18S", "model_qualifier": "", "winter_efficiency_pct": 89.6, "summer_efficiency_pct": 80.6, "comparative_hot_water_efficiency_pct": 58.9, "output_kw_max": 18.3, "final_year_of_manufacture": null, "raw": ["016658", "000001", "0", "2013/Mar/28 08:26", "Alpha Therm", "Alpha", "InTec 18S", "", "", "2011", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "18.3", "18.3", "", "", "89.6", "80.6", "", "58.9", "", "2", "1", "", "102", "1", "2", "115", "6", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.4", "100.3", "", "", "", "", "98.4"]} -{"pcdb_id": 16659, "brand_name": "Alpha", "model_name": "InTec 12S", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 12.0, "final_year_of_manufacture": null, "raw": ["016659", "000001", "0", "2013/Mar/28 08:26", "Alpha Therm", "Alpha", "InTec 12S", "", "", "2011", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "12", "12", "", "", "88.1", "79.1", "", "57.7", "", "2", "", "", "102", "1", "2", "115", "6", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "97.0", "", "", "", "", "95.3"]} -{"pcdb_id": 16660, "brand_name": "Alpha", "model_name": "InTec 12S", "model_qualifier": "", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 12.0, "final_year_of_manufacture": null, "raw": ["016660", "000001", "0", "2013/Mar/28 08:26", "Alpha Therm", "Alpha", "InTec 12S", "", "", "2011", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "12", "12", "", "", "89.1", "80.1", "", "58.5", "", "2", "1", "", "102", "1", "2", "115", "6", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.7", "99.2", "", "", "", "", "97.4"]} -{"pcdb_id": 16661, "brand_name": "Alpha", "model_name": "InTec 34C", "model_qualifier": "", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 87.0, "comparative_hot_water_efficiency_pct": 76.8, "output_kw_max": 28.0, "final_year_of_manufacture": null, "raw": ["016661", "000001", "0", "2016/Sep/20 00:00", "Alpha Therm", "Alpha", "InTec 34C", "", "", "2011", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28", "28", "", "", "88.2", "87.0", "", "76.8", "", "2", "", "", "104", "1", "2", "125", "6", "0", "", "", "", "0", "", "", "", "", "1", "6.856", "0.14", "0.0029", "0.75503", "", "", "", "", "", "", "", "", "1005", "", "", "", "", "", "", "", "", "88.8", "96.9", "", "", "", "", "95.3"]} -{"pcdb_id": 16662, "brand_name": "Alpha", "model_name": "InTec 34C", "model_qualifier": "", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 80.6, "comparative_hot_water_efficiency_pct": 56.7, "output_kw_max": 28.0, "final_year_of_manufacture": null, "raw": ["016662", "000001", "0", "2016/Sep/20 00:00", "Alpha Therm", "Alpha", "InTec 34C", "", "", "2011", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "28", "28", "", "", "89.2", "80.6", "", "56.7", "", "2", "1", "", "104", "1", "2", "125", "6", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "1005", "", "", "", "", "", "", "", "", "90.8", "99.0", "", "", "", "", "97.5"]} -{"pcdb_id": 16663, "brand_name": "Alpha", "model_name": "InTec 30C", "model_qualifier": "", "winter_efficiency_pct": 87.6, "summer_efficiency_pct": 86.9, "comparative_hot_water_efficiency_pct": 74.8, "output_kw_max": 24.0, "final_year_of_manufacture": null, "raw": ["016663", "000001", "0", "2016/Sep/20 00:00", "Alpha Therm", "Alpha", "InTec 30C", "", "", "2011", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.0", "24.0", "", "", "87.6", "86.9", "", "74.8", "", "2", "", "", "104", "1", "2", "120", "6", "0", "", "", "", "0", "", "", "", "", "1", "7.039", "0.15", "0.0049", "0.91795", "", "", "", "", "", "", "", "", "1005", "", "", "", "", "", "", "", "", "88.7", "95.5", "", "", "", "", "94.2"]} -{"pcdb_id": 16664, "brand_name": "Alpha", "model_name": "InTec 30C", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 56.3, "output_kw_max": 24.0, "final_year_of_manufacture": null, "raw": ["016664", "000001", "0", "2016/Sep/20 00:00", "Alpha Therm", "Alpha", "InTec 30C", "", "", "2011", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24.0", "24.0", "", "", "88.6", "80.0", "", "56.3", "", "2", "1", "", "104", "1", "2", "120", "6", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "1005", "", "", "", "", "", "", "", "", "90.7", "97.6", "", "", "", "", "96.3"]} -{"pcdb_id": 16665, "brand_name": "Alpha", "model_name": "InTec 26C", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 86.8, "comparative_hot_water_efficiency_pct": 76.6, "output_kw_max": 18.3, "final_year_of_manufacture": null, "raw": ["016665", "000001", "0", "2011/Oct/28 08:07", "Alpha Therm", "Alpha", "InTec 26C", "", "", "2011", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "18.3", "18.3", "", "", "88.6", "86.8", "", "76.6", "", "2", "", "", "104", "1", "2", "115", "6", "0", "", "", "", "0", "", "", "", "", "1", "6.876", "0.14", "0.0025", "0.76768", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.5", "98.1", "", "", "", "", "96.3"]} -{"pcdb_id": 16666, "brand_name": "Alpha", "model_name": "InTec 26C", "model_qualifier": "", "winter_efficiency_pct": 89.6, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 57.0, "output_kw_max": 18.3, "final_year_of_manufacture": null, "raw": ["016666", "000001", "0", "2013/Apr/08 09:44", "Alpha Therm", "Alpha", "InTec 26C", "", "", "2011", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "18.3", "18.3", "", "", "89.6", "81.0", "", "57.0", "", "2", "1", "", "104", "1", "2", "115", "6", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.4", "100.3", "", "", "", "", "98.4"]} -{"pcdb_id": 16667, "brand_name": "Alpha", "model_name": "InTec 24X", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 86.8, "comparative_hot_water_efficiency_pct": 75.4, "output_kw_max": 18.3, "final_year_of_manufacture": null, "raw": ["016667", "000001", "0", "2011/Jul/28 11:07", "Alpha Therm", "Alpha", "InTec 24X", "", "", "2011", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "18.3", "18.3", "", "", "88.6", "86.8", "", "75.4", "", "2", "", "", "104", "1", "2", "115", "6", "0", "", "", "", "0", "", "", "", "", "1", "6.983", "0.13", "0.004", "0.86204", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.5", "98.1", "", "", "", "", "96.3"]} -{"pcdb_id": 16668, "brand_name": "Alpha", "model_name": "InTec 24X", "model_qualifier": "", "winter_efficiency_pct": 89.6, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 57.0, "output_kw_max": 18.3, "final_year_of_manufacture": null, "raw": ["016668", "000001", "0", "2013/Apr/08 09:44", "Alpha Therm", "Alpha", "InTec 24X", "", "", "2011", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "18.3", "18.3", "", "", "89.6", "81.0", "", "57.0", "", "2", "1", "", "104", "1", "2", "115", "6", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.4", "100.3", "", "", "", "", "98.4"]} -{"pcdb_id": 16669, "brand_name": "Alpha", "model_name": "InTec 28X", "model_qualifier": "", "winter_efficiency_pct": 87.6, "summer_efficiency_pct": 86.9, "comparative_hot_water_efficiency_pct": 77.2, "output_kw_max": 24.0, "final_year_of_manufacture": null, "raw": ["016669", "000001", "0", "2011/Jul/28 11:08", "Alpha Therm", "Alpha", "InTec 28X", "", "", "2011", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "87.6", "86.9", "", "77.2", "", "2", "", "", "104", "1", "2", "120", "6", "0", "", "", "", "0", "", "", "", "", "1", "6.821", "0.15", "0.0025", "0.72165", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.7", "95.5", "", "", "", "", "94.2"]} -{"pcdb_id": 16670, "brand_name": "Alpha", "model_name": "InTec 28X", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 56.3, "output_kw_max": 24.0, "final_year_of_manufacture": null, "raw": ["016670", "000001", "0", "2013/Apr/08 09:44", "Alpha Therm", "Alpha", "InTec 28X", "", "", "2011", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "88.6", "80.0", "", "56.3", "", "2", "1", "", "104", "1", "2", "120", "6", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.7", "97.6", "", "", "", "", "96.3"]} -{"pcdb_id": 16673, "brand_name": "Ariston", "model_name": "E-System 24", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 21.6, "final_year_of_manufacture": 2013, "raw": ["016673", "000080", "0", "2013/Nov/04 15:27", "Ariston Thermo UK", "Ariston", "E-System 24", "", "", "2010", "2013", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "21.6", "21.6", "", "", "88.3", "79.3", "", "57.9", "", "2", "", "", "102", "1", "2", "120", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "97.3", "", "", "", "", "95.6"]} -{"pcdb_id": 16674, "brand_name": "Ariston", "model_name": "E-System 30", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 27.4, "final_year_of_manufacture": 2013, "raw": ["016674", "000080", "0", "2013/Nov/04 15:27", "Ariston Thermo UK", "Ariston", "E-System 30", "", "", "2010", "2013", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "27.4", "27.4", "", "", "88.3", "79.3", "", "57.9", "", "2", "", "", "102", "1", "2", "120", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "97.5", "", "", "", "", "95.7"]} -{"pcdb_id": 16675, "brand_name": "Baxi", "model_name": "Megaflo 2 System", "model_qualifier": "28 Compact GA", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 28.0, "final_year_of_manufacture": 2015, "raw": ["016675", "000005", "0", "2015/Aug/06 12:01", "Baxi Heating UK", "Baxi", "Megaflo 2 System", "28 Compact GA", "GC No 41-075-74", "2011", "2015", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "28", "28", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "135", "3.5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "90.0", "96.9", "", "", "", "", "95.6"]} -{"pcdb_id": 16676, "brand_name": "Baxi", "model_name": "Megaflo 2 System", "model_qualifier": "32 Compact GA", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 32.0, "final_year_of_manufacture": 2015, "raw": ["016676", "000005", "0", "2015/Aug/06 11:59", "Baxi Heating UK", "Baxi", "Megaflo 2 System", "32 Compact GA", "GC No 41-075-75", "2011", "2015", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "32", "32", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "132", "3.5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "90.0", "96.9", "", "", "", "", "95.6"]} -{"pcdb_id": 16677, "brand_name": "Baxi", "model_name": "Megaflo 2 System", "model_qualifier": "24 Compact GA", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 24.0, "final_year_of_manufacture": 2015, "raw": ["016677", "000005", "0", "2015/Aug/06 12:01", "Baxi Heating UK", "Baxi", "Megaflo 2 System", "24 Compact GA", "41-075-73", "2011", "2015", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24", "24", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "104", "3.5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "90.0", "96.9", "", "", "", "", "95.6"]} -{"pcdb_id": 16679, "brand_name": "Baxi", "model_name": "Megaflo 2 System", "model_qualifier": "18 Compact GA", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 18.0, "final_year_of_manufacture": 2015, "raw": ["016679", "000005", "0", "2015/Aug/06 12:02", "Baxi Heating UK", "Baxi", "Megaflo 2 System", "18 Compact GA", "GC No 41-075-72", "2011", "2015", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18", "18", "", "", "88.2", "79.2", "", "57.8", "", "2", "", "", "102", "1", "2", "125", "3.5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "90.0", "96.4", "", "", "", "", "95.2"]} -{"pcdb_id": 16680, "brand_name": "Baxi", "model_name": "Megaflo 2 System", "model_qualifier": "15 Compact GA", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 15.0, "final_year_of_manufacture": 2015, "raw": ["016680", "000005", "0", "2015/Aug/06 12:03", "Baxi Heating UK", "Baxi", "Megaflo 2 System", "15 Compact GA", "GC No 41-075-71", "2011", "2015", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "15", "15", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "108", "3.5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "90.0", "97.0", "", "", "", "", "95.7"]} -{"pcdb_id": 16681, "brand_name": "Baxi", "model_name": "Megaflo 2 System", "model_qualifier": "12 Compact GA", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 12.0, "final_year_of_manufacture": 2015, "raw": ["016681", "000005", "0", "2015/Aug/06 12:04", "Baxi Heating UK", "Baxi", "Megaflo 2 System", "12 Compact GA", "GC No 41-075-70", "2011", "2015", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "12", "12", "", "", "88.5", "79.5", "", "58.0", "", "2", "", "", "102", "1", "2", "110", "3.5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "90.0", "97.1", "", "", "", "", "95.8"]} -{"pcdb_id": 16682, "brand_name": "Baxi", "model_name": "Neta-tec Combi", "model_qualifier": "33 GA", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 77.2, "output_kw_max": 28.0, "final_year_of_manufacture": 2015, "raw": ["016682", "000005", "0", "2015/Aug/06 12:04", "Baxi Heating UK", "Baxi", "Neta-tec Combi", "33 GA", "GC No 47-075-53", "2011", "2015", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28", "28", "", "", "88.4", "87.3", "", "77.2", "", "2", "", "", "104", "1", "2", "133", "3.5", "0", "", "", "", "0", "", "", "", "", "1", "6.821", "0.106", "0.0045", "0.74098", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "90.0", "97.0", "", "", "", "", "95.7"]} -{"pcdb_id": 16683, "brand_name": "Baxi", "model_name": "Neta-tec Combi", "model_qualifier": "28 GA", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 77.3, "output_kw_max": 24.0, "final_year_of_manufacture": 2015, "raw": ["016683", "000005", "0", "2015/Aug/06 12:05", "Baxi Heating UK", "Baxi", "Neta-tec Combi", "28 GA", "GC No 47-075-52", "2011", "2015", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "88.4", "87.3", "", "77.3", "", "2", "", "", "104", "1", "2", "116", "3.5", "0", "", "", "", "0", "", "", "", "", "1", "6.813", "0.118", "0.0044", "0.73349", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "90.0", "96.9", "", "", "", "", "95.6"]} -{"pcdb_id": 16684, "brand_name": "Baxi", "model_name": "Neta-tec Combi", "model_qualifier": "24 GA", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 77.6, "output_kw_max": 20.0, "final_year_of_manufacture": 2015, "raw": ["016684", "000005", "0", "2015/Aug/06 12:05", "Baxi Heating UK", "Baxi", "Neta-tec Combi", "24 GA", "GC No 47-075-51", "2011", "2015", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "20", "20", "", "", "88.4", "87.3", "", "77.6", "", "2", "", "", "104", "1", "2", "104", "3.5", "0", "", "", "", "0", "", "", "", "", "1", "6.786", "0.118", "0.0043", "0.70793", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "90.0", "96.9", "", "", "", "", "95.6"]} -{"pcdb_id": 16685, "brand_name": "Baxi", "model_name": "Duo-tec 2 Combi", "model_qualifier": "40 GA", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 77.8, "output_kw_max": 32.0, "final_year_of_manufacture": 2015, "raw": ["016685", "000005", "0", "2015/Aug/06 12:06", "Baxi Heating UK", "Baxi", "Duo-tec 2 Combi", "40 GA", "GC No 47-075-57", "2011", "2015", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "32", "32", "", "", "88.4", "87.3", "", "77.8", "", "2", "", "", "104", "1", "2", "142", "3.5", "0", "", "", "", "0", "", "", "", "", "1", "6.765", "0.111", "0.0036", "0.69163", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "90.0", "96.9", "", "", "", "", "95.6"]} -{"pcdb_id": 16686, "brand_name": "Baxi", "model_name": "Duo-tec 2 Combi", "model_qualifier": "24 GA", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 77.6, "output_kw_max": 20.0, "final_year_of_manufacture": 2015, "raw": ["016686", "000005", "0", "2015/Aug/06 12:06", "Baxi Heating UK", "Baxi", "Duo-tec 2 Combi", "24 GA", "GC No 41-075-54", "2011", "2015", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "20", "20", "", "", "88.4", "87.3", "", "77.6", "", "2", "", "", "104", "1", "2", "104", "3.5", "0", "", "", "", "0", "", "", "", "", "1", "6.786", "0.118", "0.0043", "0.70793", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "90.0", "96.9", "", "", "", "", "95.6"]} -{"pcdb_id": 16687, "brand_name": "Baxi", "model_name": "Duo-tec 2 Combi", "model_qualifier": "28 GA", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 77.3, "output_kw_max": 24.0, "final_year_of_manufacture": 2015, "raw": ["016687", "000005", "0", "2015/Aug/06 12:07", "Baxi Heating UK", "Baxi", "Duo-tec 2 Combi", "28 GA", "GC No 41-075-55", "2011", "2015", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "88.4", "87.3", "", "77.3", "", "2", "", "", "104", "1", "2", "116", "3.5", "0", "", "", "", "0", "", "", "", "", "1", "6.813", "0.118", "0.0044", "0.73349", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "90.0", "96.9", "", "", "", "", "95.6"]} -{"pcdb_id": 16688, "brand_name": "Baxi", "model_name": "Duo-tec 2 Combi", "model_qualifier": "33 GA", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 77.2, "output_kw_max": 28.0, "final_year_of_manufacture": 2015, "raw": ["016688", "000005", "0", "2015/Aug/06 12:07", "Baxi Heating UK", "Baxi", "Duo-tec 2 Combi", "33 GA", "GC No. 47-075-56", "2011", "2015", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28", "28", "", "", "88.4", "87.3", "", "77.2", "", "2", "", "", "104", "1", "2", "132", "3.5", "0", "", "", "", "0", "", "", "", "", "1", "6.821", "0.106", "0.0045", "0.74098", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "90.0", "97.0", "", "", "", "", "95.7"]} -{"pcdb_id": 16689, "brand_name": "Unical", "model_name": "Alkon C 28 HE", "model_qualifier": "", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 56.3, "output_kw_max": 27.3, "final_year_of_manufacture": null, "raw": ["016689", "000263", "0", "2011/Sep/28 09:21", "Unical AG", "Unical", "Alkon C 28 HE", "", "41010159GB", "2011", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "27.3", "27.3", "", "", "88.7", "80.1", "", "56.3", "", "2", "", "", "104", "1", "2", "133", "4", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "98.5", "", "", "", "", "96.5"]} -{"pcdb_id": 16690, "brand_name": "Unical", "model_name": "Alkon R 28 HE", "model_qualifier": "", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 27.3, "final_year_of_manufacture": null, "raw": ["016690", "000263", "0", "2012/Mar/27 10:12", "Unical AG", "Unical", "Alkon R 28 HE", "", "41010181GB", "2011", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "27.3", "27.3", "", "", "88.7", "79.7", "", "58.2", "", "2", "", "", "102", "1", "2", "130", "4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "98.5", "", "", "", "", "96.5"]} -{"pcdb_id": 16691, "brand_name": "Unical", "model_name": "Alkon R 35 HE", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 33.8, "final_year_of_manufacture": null, "raw": ["016691", "000263", "0", "2012/Mar/27 10:12", "Unical AG", "Unical", "Alkon R 35 HE", "", "41010182GB", "2011", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "33.8", "33.8", "", "", "88.8", "79.8", "", "58.3", "", "2", "", "", "102", "1", "2", "130", "4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.2", "98.7", "", "", "", "", "96.7"]} -{"pcdb_id": 16692, "brand_name": "Unical", "model_name": "Alkon C 35 HE", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 56.4, "output_kw_max": 33.8, "final_year_of_manufacture": null, "raw": ["016692", "000263", "0", "2011/Sep/28 09:26", "Unical AG", "Unical", "Alkon C 35 HE", "", "41010160GB", "2011", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "33.8", "33.8", "", "", "88.8", "80.2", "", "56.4", "", "2", "", "", "104", "1", "2", "133", "4", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.2", "98.7", "", "", "", "", "96.7"]} -{"pcdb_id": 16693, "brand_name": "Vokera", "model_name": "Mynute", "model_qualifier": "25A", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 24.4, "final_year_of_manufacture": null, "raw": ["016693", "000011", "0", "2012/Mar/27 10:12", "Vokera", "Vokera", "Mynute", "25A", "41 094 72", "2010", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "24.4", "24.4", "", "", "88.3", "79.3", "", "57.9", "", "2", "", "", "102", "1", "2", "128", "4.5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "97.6", "", "", "", "", "95.7"]} -{"pcdb_id": 16694, "brand_name": "Biasi", "model_name": "Riva Plus HE", "model_qualifier": "M296.24SM/C", "winter_efficiency_pct": 87.4, "summer_efficiency_pct": 86.6, "comparative_hot_water_efficiency_pct": 67.4, "output_kw_max": 24.4, "final_year_of_manufacture": null, "raw": ["016694", "000208", "0", "2011/Jun/20 11:20", "Biasi UK", "Biasi", "Riva Plus HE", "M296.24SM/C", "47-583-24", "2011", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.4", "24.4", "", "", "87.4", "86.6", "", "67.4", "", "2", "", "", "104", "1", "2", "140", "3", "0", "", "", "", "0", "", "", "", "", "1", "7.816", "0.131", "0.005", "1.63862", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "95.4", "", "", "", "", "94.0"]} -{"pcdb_id": 16695, "brand_name": "Biasi", "model_name": "Riva Plus HE", "model_qualifier": "M296.24SM/C", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 56.1, "output_kw_max": 24.4, "final_year_of_manufacture": null, "raw": ["016695", "000208", "0", "2013/Apr/08 09:45", "Biasi UK", "Biasi", "Riva Plus HE", "M296.24SM/C", "", "2011", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24.4", "24.4", "", "", "88.4", "79.8", "", "56.1", "", "2", "1", "", "104", "1", "2", "140", "3", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.7", "97.5", "", "", "", "", "96.0"]} -{"pcdb_id": 16696, "brand_name": "Biasi", "model_name": "Riva Plus HE", "model_qualifier": "M296.28SM/C", "winter_efficiency_pct": 87.4, "summer_efficiency_pct": 86.7, "comparative_hot_water_efficiency_pct": 68.0, "output_kw_max": 28.3, "final_year_of_manufacture": null, "raw": ["016696", "000208", "0", "2011/Jun/20 11:22", "Biasi UK", "Biasi", "Riva Plus HE", "M296.28SM/C", "47-583-25", "2011", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28.3", "28.3", "", "", "87.4", "86.7", "", "68.0", "", "2", "", "", "104", "1", "2", "150", "3", "0", "", "", "", "0", "", "", "", "", "1", "7.75", "0.137", "0.013", "1.53602", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "95.2", "", "", "", "", "93.9"]} -{"pcdb_id": 16697, "brand_name": "Biasi", "model_name": "Riva Plus HE", "model_qualifier": "M296.28SM/C", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 56.1, "output_kw_max": 28.3, "final_year_of_manufacture": null, "raw": ["016697", "000208", "0", "2013/Apr/08 09:45", "Biasi UK", "Biasi", "Riva Plus HE", "M296.28SM/C", "", "2011", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "28.3", "28.3", "", "", "88.4", "79.8", "", "56.1", "", "2", "1", "", "104", "1", "2", "150", "3", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.0", "97.3", "", "", "", "", "95.9"]} -{"pcdb_id": 16698, "brand_name": "Biasi", "model_name": "Riva Plus HE", "model_qualifier": "M296.24SR/C", "winter_efficiency_pct": 87.4, "summer_efficiency_pct": 78.4, "comparative_hot_water_efficiency_pct": 57.3, "output_kw_max": 24.4, "final_year_of_manufacture": null, "raw": ["016698", "000208", "0", "2012/Mar/27 10:12", "Biasi UK", "Biasi", "Riva Plus HE", "M296.24SR/C", "41-583-18", "2011", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24.4", "24.4", "", "", "87.4", "78.4", "", "57.3", "", "2", "", "", "102", "1", "2", "140", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "95.4", "", "", "", "", "94.0"]} -{"pcdb_id": 16699, "brand_name": "Biasi", "model_name": "Riva Plus HE", "model_qualifier": "M296.24SR/C", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 24.4, "final_year_of_manufacture": null, "raw": ["016699", "000208", "0", "2012/Mar/27 10:12", "Biasi UK", "Biasi", "Riva Plus HE", "M296.24SR/C", "", "2011", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "24.4", "24.4", "", "", "88.4", "79.4", "", "58.0", "", "2", "1", "", "102", "1", "2", "140", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.7", "97.5", "", "", "", "", "96.0"]} -{"pcdb_id": 16700, "brand_name": "Biasi", "model_name": "Riva Plus HE", "model_qualifier": "M296.28SR/C", "winter_efficiency_pct": 87.4, "summer_efficiency_pct": 78.4, "comparative_hot_water_efficiency_pct": 57.3, "output_kw_max": 28.3, "final_year_of_manufacture": null, "raw": ["016700", "000208", "0", "2012/Mar/27 10:12", "Biasi UK", "Biasi", "Riva Plus HE", "M296.28SR/C", "41-583-19", "2011", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "28.3", "28.3", "", "", "87.4", "78.4", "", "57.3", "", "2", "", "", "102", "1", "2", "150", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "95.2", "", "", "", "", "93.9"]} -{"pcdb_id": 16701, "brand_name": "Biasi", "model_name": "Riva Plus HE", "model_qualifier": "M296.28SR/C", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 28.3, "final_year_of_manufacture": null, "raw": ["016701", "000208", "0", "2012/Mar/27 10:12", "Biasi UK", "Biasi", "Riva Plus HE", "M296.28SR/C", "", "2011", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "28.3", "28.3", "", "", "88.4", "79.4", "", "58.0", "", "2", "1", "", "102", "1", "2", "150", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.0", "97.3", "", "", "", "", "95.9"]} -{"pcdb_id": 16702, "brand_name": "Baxi", "model_name": "Neta-tec Combi", "model_qualifier": "24 GA", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 56.8, "output_kw_max": 20.0, "final_year_of_manufacture": null, "raw": ["016702", "000005", "0", "2013/Apr/08 09:50", "Baxi Heating UK", "Baxi", "Neta-tec Combi", "24 GA", "", "2011", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "20", "20", "", "", "89.4", "80.8", "", "56.8", "", "2", "1", "", "104", "1", "2", "104", "3.5", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "92.0", "99.1", "", "", "", "", "97.8"]} -{"pcdb_id": 16703, "brand_name": "Baxi", "model_name": "Neta-tec Combi", "model_qualifier": "28 GA", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 56.8, "output_kw_max": 24.0, "final_year_of_manufacture": null, "raw": ["016703", "000005", "0", "2013/Apr/08 09:50", "Baxi Heating UK", "Baxi", "Neta-tec Combi", "28 GA", "", "2011", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "89.4", "80.8", "", "56.8", "", "2", "1", "", "104", "1", "2", "116", "3.5", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "92.0", "99.1", "", "", "", "", "97.8"]} -{"pcdb_id": 16704, "brand_name": "Baxi", "model_name": "Neta-tec Combi", "model_qualifier": "33 GA", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 56.8, "output_kw_max": 28.0, "final_year_of_manufacture": null, "raw": ["016704", "000005", "0", "2013/Apr/08 09:50", "Baxi Heating UK", "Baxi", "Neta-tec Combi", "33 GA", "", "2011", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "28", "28", "", "", "89.4", "80.8", "", "56.8", "", "2", "1", "", "104", "1", "2", "133", "3.5", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "92.0", "99.2", "", "", "", "", "97.8"]} -{"pcdb_id": 16705, "brand_name": "Baxi", "model_name": "Duo-tec 2 Combi", "model_qualifier": "24 GA", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 56.8, "output_kw_max": 20.0, "final_year_of_manufacture": null, "raw": ["016705", "000005", "0", "2013/Apr/08 09:51", "Baxi Heating UK", "Baxi", "Duo-tec 2 Combi", "24 GA", "", "2011", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "20", "20", "", "", "89.4", "80.8", "", "56.8", "", "2", "1", "", "104", "1", "2", "104", "3.5", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "92.0", "99.1", "", "", "", "", "97.8"]} -{"pcdb_id": 16706, "brand_name": "Baxi", "model_name": "Duo-tec 2 Combi", "model_qualifier": "28 GA", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 56.8, "output_kw_max": 24.0, "final_year_of_manufacture": null, "raw": ["016706", "000005", "0", "2013/Apr/08 09:51", "Baxi Heating UK", "Baxi", "Duo-tec 2 Combi", "28 GA", "", "2011", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "89.4", "80.8", "", "56.8", "", "2", "1", "", "104", "1", "2", "116", "3.5", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "92.0", "99.1", "", "", "", "", "97.8"]} -{"pcdb_id": 16707, "brand_name": "Baxi", "model_name": "Duo-tec 2 Combi", "model_qualifier": "33 GA", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 56.8, "output_kw_max": 28.0, "final_year_of_manufacture": null, "raw": ["016707", "000005", "0", "2013/Apr/08 09:51", "Baxi Heating UK", "Baxi", "Duo-tec 2 Combi", "33 GA", "", "2011", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "28", "28", "", "", "89.4", "80.8", "", "56.8", "", "2", "1", "", "104", "1", "2", "132", "3.5", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "92.0", "99.2", "", "", "", "", "97.8"]} -{"pcdb_id": 16708, "brand_name": "Baxi", "model_name": "Duo-tec 2 Combi", "model_qualifier": "40 GA", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 56.8, "output_kw_max": 32.0, "final_year_of_manufacture": null, "raw": ["016708", "000005", "0", "2013/Apr/08 09:52", "Baxi Heating UK", "Baxi", "Duo-tec 2 Combi", "40 GA", "", "2011", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "32", "32", "", "", "89.4", "80.8", "", "56.8", "", "2", "1", "", "104", "1", "2", "142", "3.5", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "92.0", "99.1", "", "", "", "", "97.8"]} -{"pcdb_id": 16709, "brand_name": "Baxi", "model_name": "Megaflo 2 System", "model_qualifier": "12 Compact GA", "winter_efficiency_pct": 89.5, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 58.8, "output_kw_max": 12.0, "final_year_of_manufacture": null, "raw": ["016709", "000005", "0", "2012/Mar/27 10:12", "Baxi Heating UK", "Baxi", "Megaflo 2 System", "12 Compact GA", "", "2011", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "12", "12", "", "", "89.5", "80.5", "", "58.8", "", "2", "1", "", "102", "1", "2", "110", "3.5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "92.0", "99.3", "", "", "", "", "97.9"]} -{"pcdb_id": 16710, "brand_name": "Baxi", "model_name": "Megaflo 2 System", "model_qualifier": "15 Compact GA", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 80.4, "comparative_hot_water_efficiency_pct": 58.8, "output_kw_max": 15.0, "final_year_of_manufacture": null, "raw": ["016710", "000005", "0", "2012/Mar/27 10:12", "Baxi Heating UK", "Baxi", "Megaflo 2 System", "15 Compact GA", "", "2011", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "15", "15", "", "", "89.4", "80.4", "", "58.8", "", "2", "1", "", "102", "1", "2", "108", "3.5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "92.0", "99.2", "", "", "", "", "97.8"]} -{"pcdb_id": 16711, "brand_name": "Baxi", "model_name": "Megaflo 2 System", "model_qualifier": "18 Compact GA", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 80.4, "comparative_hot_water_efficiency_pct": 58.8, "output_kw_max": 18.0, "final_year_of_manufacture": null, "raw": ["016711", "000005", "0", "2012/Mar/27 10:12", "Baxi Heating UK", "Baxi", "Megaflo 2 System", "18 Compact GA", "", "2011", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "18", "18", "", "", "89.4", "80.4", "", "58.8", "", "2", "1", "", "102", "1", "2", "125", "3.5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "92.0", "99.2", "", "", "", "", "97.8"]} -{"pcdb_id": 16712, "brand_name": "Baxi", "model_name": "Megaflo 2 System", "model_qualifier": "24 Compact GA", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 80.4, "comparative_hot_water_efficiency_pct": 58.7, "output_kw_max": 24.0, "final_year_of_manufacture": null, "raw": ["016712", "000005", "0", "2012/Mar/27 10:12", "Baxi Heating UK", "Baxi", "Megaflo 2 System", "24 Compact GA", "", "2011", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "24", "24", "", "", "89.4", "80.4", "", "58.7", "", "2", "1", "", "102", "1", "2", "104", "3.5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "92.0", "99.1", "", "", "", "", "97.8"]} -{"pcdb_id": 16713, "brand_name": "Baxi", "model_name": "Megaflo 2 System", "model_qualifier": "28 Compact GA", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 80.4, "comparative_hot_water_efficiency_pct": 58.7, "output_kw_max": 28.0, "final_year_of_manufacture": null, "raw": ["016713", "000005", "0", "2012/Mar/27 10:12", "Baxi Heating UK", "Baxi", "Megaflo 2 System", "28 Compact GA", "", "2011", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "28", "28", "", "", "89.4", "80.4", "", "58.7", "", "2", "1", "", "102", "1", "2", "135", "3.5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "92.0", "99.1", "", "", "", "", "97.8"]} -{"pcdb_id": 16714, "brand_name": "Baxi", "model_name": "Megaflo 2 System", "model_qualifier": "32 Compact GA", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 80.4, "comparative_hot_water_efficiency_pct": 58.7, "output_kw_max": 32.0, "final_year_of_manufacture": null, "raw": ["016714", "000005", "0", "2012/Mar/27 10:12", "Baxi Heating UK", "Baxi", "Megaflo 2 System", "32 Compact GA", "", "2011", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "32", "32", "", "", "89.4", "80.4", "", "58.7", "", "2", "1", "", "102", "1", "2", "132", "3.5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "92.0", "99.1", "", "", "", "", "97.8"]} -{"pcdb_id": 16715, "brand_name": "Sime", "model_name": "Estelle HE", "model_qualifier": "5", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 80.7, "comparative_hot_water_efficiency_pct": 59.0, "output_kw_max": 38.8, "final_year_of_manufacture": null, "raw": ["016715", "000213", "0", "2015/Oct/08 11:02", "Fonderie Sime S.p.A.", "Sime", "Estelle HE", "5", "", "2010", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "38.8", "38.8", "", "", "88.5", "80.7", "", "59.0", "", "2", "", "", "201", "1", "1", "260", "0.1", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.9", "96.0", "", "", "", "", "95.1"]} -{"pcdb_id": 16716, "brand_name": "Sime", "model_name": "Estelle HE", "model_qualifier": "4", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 80.7, "comparative_hot_water_efficiency_pct": 59.0, "output_kw_max": 28.8, "final_year_of_manufacture": null, "raw": ["016716", "000213", "0", "2015/Oct/08 11:02", "Fonderie Sime S.p.A.", "Sime", "Estelle HE", "4", "", "2010", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "28.8", "28.8", "", "", "88.5", "80.7", "", "59.0", "", "2", "", "", "201", "1", "1", "260", "0.1", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.0", "96.5", "", "", "", "", "95.3"]} -{"pcdb_id": 16717, "brand_name": "Sime", "model_name": "Estelle HE", "model_qualifier": "B4 INOX", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 81.1, "comparative_hot_water_efficiency_pct": 57.1, "output_kw_max": 28.8, "final_year_of_manufacture": null, "raw": ["016717", "000213", "0", "2015/Oct/08 11:39", "Fonderie Sime S.p.A.", "Sime", "Estelle HE", "B4 INOX", "", "2010", "current", "4", "1", "1", "2", "0", "", "", "2", "3", "2", "28.8", "28.8", "", "", "88.5", "81.1", "", "57.1", "", "2", "", "", "202", "1", "1", "260", "0.1", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.0", "96.5", "", "", "", "", "95.3"]} -{"pcdb_id": 16720, "brand_name": "Saturn", "model_name": "NHC", "model_qualifier": "25B", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 80.9, "comparative_hot_water_efficiency_pct": 56.9, "output_kw_max": 24.0, "final_year_of_manufacture": null, "raw": ["016720", "000268", "0", "2011/Nov/09 10:04", "KD Navien", "Saturn", "NHC", "25B", "", "2006", "current", "4", "1", "1", "2", "0", "", "", "2", "1", "2", "24", "24", "", "", "88.3", "80.9", "", "56.9", "", "2", "", "", "202", "1", "1", "143", "115", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "93.6", "94.4", "", "", "", "", "94.3"]} -{"pcdb_id": 16721, "brand_name": "Saturn", "model_name": "NHC", "model_qualifier": "41B", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 56.8, "output_kw_max": 38.0, "final_year_of_manufacture": null, "raw": ["016721", "000268", "0", "2011/Nov/09 10:04", "KD Navien", "Saturn", "NHC", "41B", "", "2006", "current", "4", "1", "1", "2", "0", "", "", "2", "1", "2", "38", "38", "", "", "88.2", "80.8", "", "56.8", "", "2", "", "", "202", "1", "1", "199", "140", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "93.6", "94.1", "", "", "", "", "94.0"]} -{"pcdb_id": 16722, "brand_name": "Saturn", "model_name": "NHC", "model_qualifier": "30B", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 56.9, "output_kw_max": 30.0, "final_year_of_manufacture": null, "raw": ["016722", "000268", "0", "2014/Nov/25 09:39", "KD Navien", "Saturn", "NHC", "30B", "", "2006", "current", "4", "1", "1", "2", "0", "", "", "2", "1", "2", "30", "30", "", "", "88.2", "80.8", "", "56.9", "", "2", "", "", "202", "1", "1", "150", "121", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "93.6", "94.3", "", "", "", "", "94.1"]} -{"pcdb_id": 16723, "brand_name": "Fondital", "model_name": "Antea KRB 24", "model_qualifier": "", "winter_efficiency_pct": 87.5, "summer_efficiency_pct": 78.5, "comparative_hot_water_efficiency_pct": 57.4, "output_kw_max": 22.9, "final_year_of_manufacture": null, "raw": ["016723", "000250", "0", "2012/Mar/27 10:12", "Fondital", "Fondital", "Antea KRB 24", "", "", "2011", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "22.9", "22.9", "", "", "87.5", "78.5", "", "57.4", "", "2", "", "", "102", "1", "2", "131", "80", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.1", "96.0", "", "", "", "", "94.3"]} -{"pcdb_id": 16724, "brand_name": "Fondital", "model_name": "Antea KRB 24", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 22.9, "final_year_of_manufacture": null, "raw": ["016724", "000250", "0", "2012/Mar/27 10:12", "Fondital", "Fondital", "Antea KRB 24", "", "", "2011", "current", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "22.9", "22.9", "", "", "88.5", "79.5", "", "58.1", "", "2", "1", "", "102", "1", "2", "131", "80", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.1", "98.1", "", "", "", "", "96.4"]} -{"pcdb_id": 16725, "brand_name": "Fondital", "model_name": "Antea KC 24", "model_qualifier": "", "winter_efficiency_pct": 87.5, "summer_efficiency_pct": 86.4, "comparative_hot_water_efficiency_pct": 74.3, "output_kw_max": 22.9, "final_year_of_manufacture": null, "raw": ["016725", "000250", "0", "2011/Aug/25 09:32", "Fondital", "Fondital", "Antea KC 24", "", "", "2011", "current", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "22.9", "22.9", "", "", "87.5", "86.4", "", "74.3", "", "2", "", "", "104", "1", "2", "131", "80", "0", "", "", "", "0", "", "", "", "", "1", "7.09", "0.1", "0.01", "0.89532", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.1", "96.0", "", "", "", "", "94.3"]} -{"pcdb_id": 16726, "brand_name": "Fondital", "model_name": "Antea KC 24", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 56.2, "output_kw_max": 22.9, "final_year_of_manufacture": null, "raw": ["016726", "000250", "0", "2013/Apr/08 09:55", "Fondital", "Fondital", "Antea KC 24", "", "", "2011", "current", "2", "2", "1", "2", "0", "", "", "2", "3", "2", "22.9", "22.9", "", "", "88.5", "79.9", "", "56.2", "", "2", "1", "", "104", "1", "2", "131", "80", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.1", "98.1", "", "", "", "", "96.4"]} -{"pcdb_id": 16727, "brand_name": "Fondital", "model_name": "Antea KR 24", "model_qualifier": "", "winter_efficiency_pct": 87.5, "summer_efficiency_pct": 78.5, "comparative_hot_water_efficiency_pct": 57.4, "output_kw_max": 22.9, "final_year_of_manufacture": null, "raw": ["016727", "000250", "0", "2012/Mar/27 10:12", "Fondital", "Fondital", "Antea KR 24", "", "", "2011", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "22.9", "22.9", "", "", "87.5", "78.5", "", "57.4", "", "2", "", "", "102", "1", "2", "131", "80", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.1", "96.0", "", "", "", "", "94.3"]} -{"pcdb_id": 16728, "brand_name": "Fondital", "model_name": "Antea KR 24", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 22.9, "final_year_of_manufacture": null, "raw": ["016728", "000250", "0", "2012/Mar/27 10:12", "Fondital", "Fondital", "Antea KR 24", "", "", "2011", "current", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "22.9", "22.9", "", "", "88.5", "79.5", "", "58.1", "", "2", "1", "", "102", "1", "2", "131", "80", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.1", "98.1", "", "", "", "", "96.4"]} -{"pcdb_id": 16729, "brand_name": "Baxi", "model_name": "Platinum 2 Combi", "model_qualifier": "28 GA", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 77.3, "output_kw_max": 24.0, "final_year_of_manufacture": 2012, "raw": ["016729", "000005", "0", "2013/May/07 10:37", "Baxi Heating UK", "Baxi", "Platinum 2 Combi", "28 GA", "GL No 41-075-61", "2011", "2012", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "88.4", "87.3", "", "77.3", "", "2", "", "", "104", "1", "2", "135", "3.5", "0", "", "", "", "0", "", "", "", "", "1", "6.813", "0.118", "0.0044", "0.73349", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.0", "96.9", "", "", "", "", "95.6"]} -{"pcdb_id": 16730, "brand_name": "Baxi", "model_name": "Platinum 2 Combi", "model_qualifier": "33 GA", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 77.2, "output_kw_max": 28.0, "final_year_of_manufacture": 2012, "raw": ["016730", "000005", "0", "2013/May/07 10:37", "Baxi Heating UK", "Baxi", "Platinum 2 Combi", "33 GA", "GC No 47-075-62", "2011", "2012", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28", "28", "", "", "88.4", "87.3", "", "77.2", "", "2", "", "", "104", "1", "2", "145", "3.5", "0", "", "", "", "0", "", "", "", "", "1", "6.821", "0.106", "0.0045", "0.74098", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.0", "97.0", "", "", "", "", "95.7"]} -{"pcdb_id": 16731, "brand_name": "Baxi", "model_name": "Platinum 2 Combi", "model_qualifier": "40 GA", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 77.8, "output_kw_max": 32.0, "final_year_of_manufacture": 2012, "raw": ["016731", "000005", "0", "2013/May/07 10:38", "Baxi Heating UK", "Baxi", "Platinum 2 Combi", "40 GA", "GC No 47-075-63", "2011", "2012", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "32", "32", "", "", "88.4", "87.3", "", "77.8", "", "2", "", "", "104", "1", "2", "140", "3.5", "0", "", "", "", "0", "", "", "", "", "1", "6.765", "0.111", "0.0036", "0.69163", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.0", "96.9", "", "", "", "", "95.6"]} -{"pcdb_id": 16732, "brand_name": "Pro", "model_name": "Procombi Exclusive", "model_qualifier": "24", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 62.2, "output_kw_max": 24.2, "final_year_of_manufacture": null, "raw": ["016732", "000247", "0", "2011/Nov/07 13:46", "Ideal Boilers", "Pro", "Procombi Exclusive", "24", "47-348-79", "2011", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "88.3", "79.7", "", "62.2", "", "2", "", "", "104", "1", "2", "146", "1", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "", "0035", "", "", "", "", "", "", "", "", "89.8", "96.9", "", "", "", "", "95.5"]} -{"pcdb_id": 16733, "brand_name": "Pro", "model_name": "Procombi Exclusive", "model_qualifier": "30", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 62.3, "output_kw_max": 24.2, "final_year_of_manufacture": null, "raw": ["016733", "000247", "0", "2011/Nov/07 13:46", "Ideal Boilers", "Pro", "Procombi Exclusive", "30", "47-348-80", "2011", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "88.4", "79.8", "", "62.3", "", "2", "", "", "104", "1", "2", "152", "1", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "", "0035", "", "", "", "", "", "", "", "", "90.0", "96.9", "", "", "", "", "95.6"]} -{"pcdb_id": 16734, "brand_name": "Pro", "model_name": "Procombi Exclusive", "model_qualifier": "35", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 62.3, "output_kw_max": 24.2, "final_year_of_manufacture": null, "raw": ["016734", "000247", "0", "2011/Nov/07 13:47", "Ideal Boilers", "Pro", "Procombi Exclusive", "35", "47-348-81", "2011", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "88.4", "79.8", "", "62.3", "", "2", "", "", "104", "1", "2", "177", "1", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "", "0035", "", "", "", "", "", "", "", "", "89.8", "96.9", "", "", "", "", "95.6"]} -{"pcdb_id": 16736, "brand_name": "i", "model_name": "35", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 62.3, "output_kw_max": 24.2, "final_year_of_manufacture": null, "raw": ["016736", "000008", "0", "2013/Sep/12 14:49", "Ideal Boilers", "i", "35", "", "47-348-84", "2011", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "88.4", "79.8", "", "62.3", "", "2", "", "", "104", "1", "2", "177", "1", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "", "0035", "", "", "", "", "", "", "", "", "89.8", "96.9", "", "", "", "", "95.6"]} -{"pcdb_id": 16737, "brand_name": "i", "model_name": "30", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 62.3, "output_kw_max": 24.2, "final_year_of_manufacture": null, "raw": ["016737", "000008", "0", "2013/Sep/12 14:49", "Ideal Boilers", "i", "30", "", "47-348-83", "2011", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "88.4", "79.8", "", "62.3", "", "2", "", "", "104", "1", "2", "152", "1", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "", "0035", "", "", "", "", "", "", "", "", "90.0", "96.9", "", "", "", "", "95.6"]} -{"pcdb_id": 16738, "brand_name": "i", "model_name": "24", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 62.2, "output_kw_max": 24.2, "final_year_of_manufacture": null, "raw": ["016738", "000008", "0", "2013/Sep/12 14:49", "Ideal Boilers", "i", "24", "", "47-348-82", "2011", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "88.3", "79.7", "", "62.2", "", "2", "", "", "104", "1", "2", "146", "1", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "", "0035", "", "", "", "", "", "", "", "", "89.8", "96.9", "", "", "", "", "95.5"]} -{"pcdb_id": 16739, "brand_name": "Ideal", "model_name": "Independent +", "model_qualifier": "C24", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 69.3, "output_kw_max": 24.2, "final_year_of_manufacture": 2016, "raw": ["016739", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "Independent +", "C24", "47-348-85", "2011", "2016", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "88.4", "87.3", "", "69.3", "", "2", "", "", "104", "1", "2", "146", "1", "0", "", "", "", "0", "", "", "", "", "1", "7.5959", "0.1755", "0.008", "1.46665", "", "", "", "", "", "1", "1", "", "0035", "", "", "", "", "", "", "", "", "89.8", "96.9", "", "", "", "", "95.6"]} -{"pcdb_id": 16740, "brand_name": "Ideal", "model_name": "Independent +", "model_qualifier": "C30", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 69.8, "output_kw_max": 24.2, "final_year_of_manufacture": 2016, "raw": ["016740", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "Independent +", "C30", "47-348-86", "2011", "2016", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "88.4", "87.3", "", "69.8", "", "2", "", "", "104", "1", "2", "152", "1", "0", "", "", "", "0", "", "", "", "", "1", "7.548", "0.1749", "0.0099", "1.41408", "", "", "", "", "", "1", "1", "", "0035", "", "", "", "", "", "", "", "", "90.0", "96.9", "", "", "", "", "95.6"]} -{"pcdb_id": 16741, "brand_name": "Ideal", "model_name": "Independent +", "model_qualifier": "C35", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 71.0, "output_kw_max": 24.2, "final_year_of_manufacture": 2016, "raw": ["016741", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "Independent +", "C35", "47-348-87", "2011", "2016", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "88.3", "87.3", "", "71.0", "", "2", "", "", "104", "1", "2", "177", "1", "0", "", "", "", "0", "", "", "", "", "1", "7.4216", "0.171", "0.0087", "1.2937", "", "", "", "", "", "1", "1", "", "0035", "", "", "", "", "", "", "", "", "89.8", "96.9", "", "", "", "", "95.5"]} -{"pcdb_id": 16742, "brand_name": "Ideal", "model_name": "Independent System", "model_qualifier": "15", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 15.0, "final_year_of_manufacture": 2016, "raw": ["016742", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "Independent System", "15", "41-750-48", "2011", "2016", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "15", "15", "", "", "88.6", "79.6", "", "58.2", "", "2", "", "", "102", "1", "2", "126", "1", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "89.7", "97.7", "", "", "", "", "96.2"]} -{"pcdb_id": 16743, "brand_name": "Ideal", "model_name": "Independent System", "model_qualifier": "18", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 18.0, "final_year_of_manufacture": 2016, "raw": ["016743", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "Independent System", "18", "47-750-49", "2011", "2016", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18", "18", "", "", "88.5", "79.5", "", "58.1", "", "2", "", "", "102", "1", "2", "131", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "89.6", "97.4", "", "", "", "", "95.9"]} -{"pcdb_id": 16744, "brand_name": "Ideal", "model_name": "Independent System", "model_qualifier": "24", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 24.2, "final_year_of_manufacture": 2016, "raw": ["016744", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "Independent System", "24", "41-750-50", "2011", "2016", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "88.8", "79.8", "", "58.3", "", "2", "", "", "102", "1", "2", "146", "1", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "89.6", "98.0", "", "", "", "", "96.4"]} -{"pcdb_id": 16745, "brand_name": "Ideal", "model_name": "Independent System", "model_qualifier": "30", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 30.3, "final_year_of_manufacture": 2016, "raw": ["016745", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "Independent System", "30", "41/750/51", "2011", "2016", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "30.3", "30.3", "", "", "88.9", "79.9", "", "58.3", "", "2", "", "", "102", "1", "2", "152", "1", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "89.8", "98.2", "", "", "", "", "96.6"]} -{"pcdb_id": 16746, "brand_name": "Vokera", "model_name": "Mynute", "model_qualifier": "35 HE", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 33.67, "final_year_of_manufacture": null, "raw": ["016746", "000011", "0", "2012/Mar/27 10:12", "Vokera", "Vokera", "Mynute", "35 HE", "4109464", "2006", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "33.67", "33.67", "", "", "88.1", "79.1", "", "57.8", "", "2", "", "", "102", "1", "2", "165", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.7", "97.1", "", "", "", "", "95.3"]} -{"pcdb_id": 16747, "brand_name": "Sime", "model_name": "Murelle Equipe", "model_qualifier": "50BOX", "winter_efficiency_pct": 89.3, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 58.7, "output_kw_max": 46.7, "final_year_of_manufacture": 2018, "raw": ["016747", "000213", "0", "2018/Jul/11 10:02", "Fonderie Sime S.p.A.", "Sime", "Murelle Equipe", "50BOX", "", "2011", "2018", "2", "2", "2", "1", "0", "", "", "2", "2", "2", "46.7", "46.7", "", "", "89.3", "80.3", "", "58.7", "", "2", "1", "", "102", "1", "2", "180", "4.4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.7", "99.9", "", "", "", "", "98.0"]} -{"pcdb_id": 16748, "brand_name": "Sime", "model_name": "Murelle Equipe", "model_qualifier": "50BOX", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 46.7, "final_year_of_manufacture": null, "raw": ["016748", "000213", "0", "2015/Oct/08 12:07", "Fonderie Sime S.p.A.", "Sime", "Murelle Equipe", "50BOX", "", "2011", "current", "1", "2", "2", "1", "0", "", "", "2", "2", "2", "46.7", "46.7", "", "", "88.3", "79.3", "", "58.0", "", "2", "", "", "102", "1", "2", "180", "4.4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "97.8", "", "", "", "", "95.9"]} -{"pcdb_id": 16749, "brand_name": "Sime", "model_name": "Murelle HE", "model_qualifier": "50R", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 80.4, "comparative_hot_water_efficiency_pct": 58.7, "output_kw_max": 46.8, "final_year_of_manufacture": 2018, "raw": ["016749", "000213", "0", "2018/Mar/07 10:12", "Fonderie Sime S.p.A.", "Sime", "Murelle HE", "50R", "", "2011", "2018", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "46.8", "46.8", "", "", "89.4", "80.4", "", "58.7", "", "2", "1", "", "102", "1", "2", "180", "4.4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.1", "99.9", "", "", "", "", "98.1"]} -{"pcdb_id": 16750, "brand_name": "Sime", "model_name": "Murelle HE", "model_qualifier": "50R", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 46.8, "final_year_of_manufacture": 2018, "raw": ["016750", "000213", "0", "2018/Mar/07 10:11", "Fonderie Sime S.p.A.", "Sime", "Murelle HE", "50R", "", "2011", "2018", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "46.8", "46.8", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "180", "4.4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.1", "97.8", "", "", "", "", "95.9"]} -{"pcdb_id": 16751, "brand_name": "Sime", "model_name": "Murelle HE", "model_qualifier": "35R", "winter_efficiency_pct": 89.5, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 58.8, "output_kw_max": 33.8, "final_year_of_manufacture": 2018, "raw": ["016751", "000213", "0", "2018/Mar/05 17:00", "Fonderie Sime S.p.A.", "Sime", "Murelle HE", "35R", "", "2011", "2018", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "33.8", "33.8", "", "", "89.5", "80.5", "", "58.8", "", "2", "1", "", "102", "1", "2", "105", "4.6", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.7", "100.3", "", "", "", "", "98.3"]} -{"pcdb_id": 16752, "brand_name": "Sime", "model_name": "Murelle HE", "model_qualifier": "35R", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 33.8, "final_year_of_manufacture": 2018, "raw": ["016752", "000213", "0", "2018/Mar/05 16:59", "Fonderie Sime S.p.A.", "Sime", "Murelle HE", "35R", "", "2011", "2018", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "33.8", "33.8", "", "", "88.5", "79.5", "", "58.1", "", "2", "", "", "102", "1", "2", "105", "4.6", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "98.1", "", "", "", "", "96.2"]} -{"pcdb_id": 16753, "brand_name": "Sime", "model_name": "Murelle HM", "model_qualifier": "35T", "winter_efficiency_pct": 89.7, "summer_efficiency_pct": 80.7, "comparative_hot_water_efficiency_pct": 59.0, "output_kw_max": 34.1, "final_year_of_manufacture": 2018, "raw": ["016753", "000213", "0", "2018/Mar/07 10:20", "Fonderie Sime S.p.A.", "Sime", "Murelle HM", "35T", "", "2011", "2018", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "34.1", "34.1", "", "", "89.7", "80.7", "", "59.0", "", "2", "1", "", "102", "1", "2", "105", "4.6", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "91.1", "100.3", "", "", "", "", "98.5"]} -{"pcdb_id": 16754, "brand_name": "Sime", "model_name": "Murelle HM", "model_qualifier": "35T", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 34.1, "final_year_of_manufacture": 2018, "raw": ["016754", "000213", "0", "2018/Mar/07 10:19", "Fonderie Sime S.p.A.", "Sime", "Murelle HM", "35T", "", "2011", "2018", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "34.1", "34.1", "", "", "88.7", "79.7", "", "58.2", "", "2", "", "", "102", "1", "2", "105", "4.6", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.1", "98.1", "", "", "", "", "96.4"]} -{"pcdb_id": 16755, "brand_name": "Sime", "model_name": "Murelle HM", "model_qualifier": "25T", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 80.4, "comparative_hot_water_efficiency_pct": 58.7, "output_kw_max": 23.9, "final_year_of_manufacture": 2018, "raw": ["016755", "000213", "0", "2018/Mar/07 10:16", "Fonderie Sime S.p.A.", "Sime", "Murelle HM", "25T", "", "2011", "2018", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "23.9", "23.9", "", "", "89.4", "80.4", "", "58.7", "", "2", "1", "", "102", "1", "2", "90", "3.4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "91.1", "99.6", "", "", "", "", "98.0"]} -{"pcdb_id": 16756, "brand_name": "Sime", "model_name": "Murelle HM", "model_qualifier": "25T", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 23.9, "final_year_of_manufacture": 2018, "raw": ["016756", "000213", "0", "2018/Mar/07 10:15", "Fonderie Sime S.p.A.", "Sime", "Murelle HM", "25T", "", "2011", "2018", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "23.9", "23.9", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "90", "3.4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.1", "97.4", "", "", "", "", "95.8"]} -{"pcdb_id": 16757, "brand_name": "Sime", "model_name": "Murelle HM", "model_qualifier": "25", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 56.8, "output_kw_max": 23.9, "final_year_of_manufacture": 2018, "raw": ["016757", "000213", "0", "2018/Mar/07 10:14", "Fonderie Sime S.p.A.", "Sime", "Murelle HM", "25", "", "2011", "2018", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "23.9", "23.9", "", "", "89.4", "80.8", "", "56.8", "", "2", "1", "", "104", "1", "2", "90", "3.4", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "91.1", "99.6", "", "", "", "", "98.0"]} -{"pcdb_id": 16758, "brand_name": "Sime", "model_name": "Murelle HM", "model_qualifier": "25", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 56.1, "output_kw_max": 23.9, "final_year_of_manufacture": 2018, "raw": ["016758", "000213", "0", "2018/Mar/07 10:14", "Fonderie Sime S.p.A.", "Sime", "Murelle HM", "25", "", "2011", "2018", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "23.9", "23.9", "", "", "88.4", "79.8", "", "56.1", "", "2", "", "", "104", "1", "2", "90", "3.4", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.1", "97.4", "", "", "", "", "95.8"]} -{"pcdb_id": 16759, "brand_name": "Sime", "model_name": "Murelle HM", "model_qualifier": "35", "winter_efficiency_pct": 89.7, "summer_efficiency_pct": 81.1, "comparative_hot_water_efficiency_pct": 57.0, "output_kw_max": 34.1, "final_year_of_manufacture": 2018, "raw": ["016759", "000213", "0", "2018/Mar/07 10:19", "Fonderie Sime S.p.A.", "Sime", "Murelle HM", "35", "", "2011", "2018", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "34.1", "34.1", "", "", "89.7", "81.1", "", "57.0", "", "2", "1", "", "104", "1", "2", "105", "4.6", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "91.1", "100.3", "", "", "", "", "98.5"]} -{"pcdb_id": 16760, "brand_name": "Sime", "model_name": "Murelle HM", "model_qualifier": "35", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 56.3, "output_kw_max": 34.1, "final_year_of_manufacture": 2018, "raw": ["016760", "000213", "0", "2018/Mar/07 10:18", "Fonderie Sime S.p.A.", "Sime", "Murelle HM", "35", "", "2011", "2018", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "34.1", "34.1", "", "", "88.7", "80.1", "", "56.3", "", "2", "", "", "104", "1", "2", "105", "4.6", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.1", "98.1", "", "", "", "", "96.4"]} -{"pcdb_id": 16761, "brand_name": "Sime", "model_name": "Murelle HM", "model_qualifier": "30", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 56.5, "output_kw_max": 28.8, "final_year_of_manufacture": 2018, "raw": ["016761", "000213", "0", "2018/Mar/07 10:17", "Fonderie Sime S.p.A.", "Sime", "Murelle HM", "30", "", "2011", "2018", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "28.8", "28.8", "", "", "88.9", "80.3", "", "56.5", "", "2", "1", "", "104", "1", "2", "90", "3.4", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.9", "98.7", "", "", "", "", "97.1"]} -{"pcdb_id": 16762, "brand_name": "Sime", "model_name": "Murelle HM", "model_qualifier": "30", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 55.8, "output_kw_max": 28.8, "final_year_of_manufacture": 2018, "raw": ["016762", "000213", "0", "2018/Mar/07 10:16", "Fonderie Sime S.p.A.", "Sime", "Murelle HM", "30", "", "2011", "2018", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28.8", "28.8", "", "", "87.9", "79.3", "", "55.8", "", "2", "", "", "104", "1", "2", "90", "3.4", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "96.6", "", "", "", "", "94.9"]} -{"pcdb_id": 16763, "brand_name": "Alpha", "model_name": "InTec 30GS", "model_qualifier": "", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 80.6, "comparative_hot_water_efficiency_pct": 56.7, "output_kw_max": 18.3, "final_year_of_manufacture": null, "raw": ["016763", "000001", "3", "2021/Nov/29 20:19", "Alpha Therm", "Alpha", "InTec 30GS", "", "", "2011", "current", "2", "2", "1", "2", "1", "313", "060040", "2", "2", "2", "18.3", "18.3", "", "", "89.2", "80.6", "", "56.7", "", "2", "1", "", "104", "1", "2", "120", "6", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "1005", "", "", "", "", "", "", "", "", "90.7", "99.1", "", "", "", "", "97.5"]} -{"pcdb_id": 16764, "brand_name": "Alpha", "model_name": "InTec 30GS", "model_qualifier": "", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 86.9, "comparative_hot_water_efficiency_pct": 81.0, "output_kw_max": 18.3, "final_year_of_manufacture": null, "raw": ["016764", "000001", "3", "2021/Nov/29 20:19", "Alpha Therm", "Alpha", "InTec 30GS", "", "", "2011", "current", "1", "2", "1", "2", "1", "313", "060039", "2", "2", "2", "18.3", "18.3", "", "", "88.2", "86.9", "", "81.0", "", "2", "", "", "104", "1", "2", "120", "6", "0", "", "", "", "0", "", "", "", "", "1", "6.5", "0.147", "0.0085", "0.37658", "", "", "", "", "", "", "", "", "1005", "", "", "", "", "", "", "", "", "88.7", "96.9", "", "", "", "", "95.4"]} -{"pcdb_id": 16765, "brand_name": "Alpha", "model_name": "InTec 40GS", "model_qualifier": "", "winter_efficiency_pct": 89.3, "summer_efficiency_pct": 80.7, "comparative_hot_water_efficiency_pct": 56.8, "output_kw_max": 28.0, "final_year_of_manufacture": null, "raw": ["016765", "000001", "3", "2021/Nov/29 20:19", "Alpha Therm", "Alpha", "InTec 40GS", "", "", "2011", "current", "2", "2", "1", "2", "1", "313", "060040", "2", "2", "2", "28", "28", "", "", "89.3", "80.7", "", "56.8", "", "2", "1", "", "104", "1", "2", "125", "6", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "1005", "", "", "", "", "", "", "", "", "91.4", "99.2", "", "", "", "", "97.7"]} -{"pcdb_id": 16766, "brand_name": "Alpha", "model_name": "InTec 40GS", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 87.1, "comparative_hot_water_efficiency_pct": 79.4, "output_kw_max": 28.0, "final_year_of_manufacture": null, "raw": ["016766", "000001", "3", "2021/Nov/29 20:19", "Alpha Therm", "Alpha", "InTec 40GS", "", "", "2011", "current", "1", "2", "1", "2", "1", "313", "060039", "2", "2", "2", "28", "28", "", "", "88.3", "87.1", "", "79.4", "", "2", "", "", "104", "1", "2", "125", "6", "0", "", "", "", "0", "", "", "", "", "1", "6.631", "0.121", "0.007", "0.52692", "", "", "", "", "", "", "", "", "1005", "", "", "", "", "", "", "", "", "89.4", "97.0", "", "", "", "", "95.6"]} -{"pcdb_id": 16767, "brand_name": "Ideal", "model_name": "Evomax", "model_qualifier": "60P", "winter_efficiency_pct": 89.8, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 59.0, "output_kw_max": 60.0, "final_year_of_manufacture": null, "raw": ["016767", "000008", "0", "2012/Mar/27 10:12", "Ideal Boilers", "Ideal", "Evomax", "60P", "GC No 41-750-42", "2011", "current", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "60", "60", "", "", "89.8", "80.8", "", "59.0", "", "2", "1", "", "102", "1", "2", "74", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "91.7", "100.1", "", "", "", "", "98.5"]} -{"pcdb_id": 16768, "brand_name": "Ideal", "model_name": "Evomax", "model_qualifier": "40P", "winter_efficiency_pct": 89.6, "summer_efficiency_pct": 80.6, "comparative_hot_water_efficiency_pct": 58.9, "output_kw_max": 40.0, "final_year_of_manufacture": null, "raw": ["016768", "000008", "0", "2012/Mar/27 10:12", "Ideal Boilers", "Ideal", "Evomax", "40P", "GC No 41-750-41", "2011", "current", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "40", "40", "", "", "89.6", "80.6", "", "58.9", "", "1", "1", "", "102", "1", "2", "148", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "91.5", "99.9", "", "", "", "", "98.3"]} -{"pcdb_id": 16769, "brand_name": "Ideal", "model_name": "Evomax", "model_qualifier": "30P", "winter_efficiency_pct": 89.9, "summer_efficiency_pct": 80.9, "comparative_hot_water_efficiency_pct": 59.1, "output_kw_max": 30.0, "final_year_of_manufacture": null, "raw": ["016769", "000008", "0", "2012/Mar/27 10:12", "Ideal Boilers", "Ideal", "Evomax", "30P", "GB No 41-750-40", "2011", "current", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "30", "30", "", "", "89.9", "80.9", "", "59.1", "", "2", "1", "", "102", "1", "2", "67", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "91.6", "100.6", "", "", "", "", "98.9"]} -{"pcdb_id": 16770, "brand_name": "Ideal", "model_name": "Evomax", "model_qualifier": "60", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 60.0, "final_year_of_manufacture": null, "raw": ["016770", "000008", "0", "2012/Mar/27 10:12", "Ideal Boilers", "Ideal", "Evomax", "60", "GC No 41-750-35A", "2001", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "60", "60", "", "", "88.7", "79.7", "", "58.2", "", "2", "", "", "102", "1", "2", "74", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.7", "97.9", "", "", "", "", "96.4"]} -{"pcdb_id": 16771, "brand_name": "Ideal", "model_name": "Evomax", "model_qualifier": "40", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 40.0, "final_year_of_manufacture": null, "raw": ["016771", "000008", "0", "2012/Mar/27 10:12", "Ideal Boilers", "Ideal", "Evomax", "40", "GC No 41-750-34A", "2011", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "40", "40", "", "", "88.6", "79.6", "", "58.2", "", "2", "", "", "102", "1", "2", "148", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.6", "97.8", "", "", "", "", "96.2"]} -{"pcdb_id": 16772, "brand_name": "Ideal", "model_name": "Evomax", "model_qualifier": "30", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 30.0, "final_year_of_manufacture": null, "raw": ["016772", "000008", "0", "2012/Mar/27 10:12", "Ideal Boilers", "Ideal", "Evomax", "30", "GC No 41-750-33A", "2011", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "30", "30", "", "", "88.9", "79.9", "", "58.4", "", "2", "", "", "102", "1", "2", "67", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.6", "98.4", "", "", "", "", "96.7"]} -{"pcdb_id": 16773, "brand_name": "Potterton", "model_name": "Gold FSB", "model_qualifier": "30 HE", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 30.0, "final_year_of_manufacture": 2015, "raw": ["016773", "000005", "0", "2015/Aug/06 13:03", "Baxi Heating UK", "Potterton", "Gold FSB", "30 HE", "GC No 41-592-32", "2011", "2015", "1", "1", "1", "1", "0", "", "", "2", "2", "2", "30", "30", "", "", "88.1", "79.1", "", "57.8", "", "2", "", "", "102", "1", "2", "1", "80", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.4", "96.4", "", "", "", "", "95.1"]} -{"pcdb_id": 16774, "brand_name": "Ideal", "model_name": "LOGIC COMBI", "model_qualifier": "E24", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 69.3, "output_kw_max": 24.2, "final_year_of_manufacture": 2012, "raw": ["016774", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "LOGIC COMBI", "E24", "47-348-88", "2011", "2012", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "88.4", "87.3", "", "69.3", "", "1", "", "", "104", "1", "2", "146", "1", "0", "", "", "", "0", "", "", "", "", "1", "7.5959", "0.1755", "0.008", "1.46665", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.8", "96.9", "", "", "", "", "95.6"]} -{"pcdb_id": 16775, "brand_name": "Ideal", "model_name": "LOGIC COMBI", "model_qualifier": "E35", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 71.0, "output_kw_max": 24.2, "final_year_of_manufacture": 2012, "raw": ["016775", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "LOGIC COMBI", "E35", "47-348-90", "2011", "2012", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "88.3", "87.3", "", "71.0", "", "2", "", "", "104", "1", "2", "177", "1", "0", "", "", "", "0", "", "", "", "", "1", "7.4216", "0.171", "0.0087", "1.2937", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.8", "96.9", "", "", "", "", "95.5"]} -{"pcdb_id": 16776, "brand_name": "Ideal", "model_name": "LOGIC COMBI", "model_qualifier": "E30", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 69.8, "output_kw_max": 24.2, "final_year_of_manufacture": 2012, "raw": ["016776", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "LOGIC COMBI", "E30", "47-348-89", "2011", "2012", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "88.4", "87.3", "", "69.8", "", "2", "", "", "104", "1", "2", "152", "1", "0", "", "", "", "0", "", "", "", "", "1", "7.548", "0.1749", "0.0099", "1.41408", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.0", "96.9", "", "", "", "", "95.6"]} -{"pcdb_id": 16777, "brand_name": "Potterton", "model_name": "British Gas Potterton Precision", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 30.0, "final_year_of_manufacture": 2015, "raw": ["016777", "000005", "0", "2015/Aug/06 13:04", "Baxi Heating UK", "Potterton", "British Gas Potterton Precision", "", "GC 41-592-33", "2001", "2015", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "30", "30", "", "", "88.1", "79.1", "", "57.8", "", "2", "", "", "102", "1", "2", "80", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.4", "96.5", "", "", "", "", "95.1"]} -{"pcdb_id": 16778, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "36LXi", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 87.0, "comparative_hot_water_efficiency_pct": 78.1, "output_kw_max": 24.0, "final_year_of_manufacture": 2012, "raw": ["016778", "000035", "0", "2012/Dec/11 10:30", "Worcester Bosch Group", "Worcester", "Greenstar", "36LXi", "47-406-30", "2011", "2012", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "89.2", "87.0", "", "78.1", "", "2", "", "", "104", "1", "2", "141", "1", "0", "", "", "", "0", "", "", "", "", "1", "6.74", "0.087", "0.0009", "0.65506", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.8", "99.6", "", "", "", "", "97.5"]} -{"pcdb_id": 16779, "brand_name": "Rotex", "model_name": "GSU 320-e", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 81.4, "comparative_hot_water_efficiency_pct": 43.9, "output_kw_max": 20.0, "final_year_of_manufacture": null, "raw": ["016779", "000246", "0", "2024/Jan/31 10:17", "Rotex Heating Systems", "Rotex", "GSU 320-e", "", "", "2007", "current", "1", "1", "1", "2", "0", "", "", "2", "3", "2", "20", "20", "", "", "88.3", "81.4", "", "43.9", "", "2", "", "", "106", "1", "2", "53", "8", "2", "2", "1", "289", "0", "70", "2", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.2", "97.9", "", "", "", "", "95.9"]} -{"pcdb_id": 16780, "brand_name": "Rotex", "model_name": "GSU 320F-e", "model_qualifier": "", "winter_efficiency_pct": 89.3, "summer_efficiency_pct": 82.4, "comparative_hot_water_efficiency_pct": 44.5, "output_kw_max": 20.0, "final_year_of_manufacture": null, "raw": ["016780", "000246", "0", "2024/Jan/31 10:17", "Rotex Heating Systems", "Rotex", "GSU 320F-e", "", "", "2007", "current", "2", "1", "1", "2", "0", "", "", "2", "3", "2", "20", "20", "", "", "89.3", "82.4", "", "44.5", "", "2", "1", "", "106", "1", "2", "53", "8", "2", "2", "1", "289", "0", "70", "2", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "0", "", "0005", "", "", "", "", "", "", "", "", "89.2", "100.1", "", "", "", "", "98.0"]} -{"pcdb_id": 16781, "brand_name": "Rotex", "model_name": "GSU 520 S-e", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 81.6, "comparative_hot_water_efficiency_pct": 36.6, "output_kw_max": 20.0, "final_year_of_manufacture": null, "raw": ["016781", "000246", "0", "2024/Jan/31 10:17", "Rotex Heating Systems", "Rotex", "GSU 520 S-e", "", "", "2007", "current", "1", "1", "1", "2", "0", "", "", "2", "3", "2", "20", "20", "", "", "88.3", "81.6", "", "36.6", "", "2", "", "", "106", "1", "2", "53", "8", "2", "2", "", "500", "0", "70", "2", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "0", "", "0005", "", "", "", "", "", "", "", "", "87.2", "97.9", "", "", "", "", "95.9"]} -{"pcdb_id": 16782, "brand_name": "Rotex", "model_name": "GSU 520SF-e", "model_qualifier": "", "winter_efficiency_pct": 89.3, "summer_efficiency_pct": 82.6, "comparative_hot_water_efficiency_pct": 37.1, "output_kw_max": 20.0, "final_year_of_manufacture": null, "raw": ["016782", "000246", "0", "2024/Jan/31 10:17", "Rotex Heating Systems", "Rotex", "GSU 520SF-e", "", "", "2007", "current", "2", "1", "1", "2", "0", "", "", "2", "3", "2", "20", "20", "", "", "89.3", "82.6", "", "37.1", "", "2", "1", "", "106", "1", "2", "53", "8", "2", "2", "1", "500", "0", "70", "2", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "0", "", "0005", "", "", "", "", "", "", "", "", "89.2", "100.1", "", "", "", "", "98.0"]} -{"pcdb_id": 16783, "brand_name": "Rotex", "model_name": "GSU 530S-e", "model_qualifier": "", "winter_efficiency_pct": 87.5, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 36.3, "output_kw_max": 30.0, "final_year_of_manufacture": null, "raw": ["016783", "000246", "0", "2024/Jan/31 10:17", "Rotex Heating Systems", "Rotex", "GSU 530S-e", "", "", "2007", "current", "1", "1", "1", "2", "0", "", "", "2", "3", "2", "30", "30", "", "", "87.5", "80.8", "", "36.3", "", "2", "", "", "106", "1", "2", "64", "8", "2", "2", "1", "500", "0", "70", "2", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "0", "", "0005", "", "", "", "", "", "", "", "", "86.5", "96.2", "", "", "", "", "94.4"]} -{"pcdb_id": 16784, "brand_name": "Rotex", "model_name": "GSU 530SF-e", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 81.8, "comparative_hot_water_efficiency_pct": 36.7, "output_kw_max": 30.0, "final_year_of_manufacture": null, "raw": ["016784", "000246", "0", "2024/Jan/31 10:17", "Rotex Heating Systems", "Rotex", "GSU 530SF-e", "", "", "2007", "current", "2", "1", "1", "2", "0", "", "", "2", "3", "2", "30", "30", "", "", "88.5", "81.8", "", "36.7", "", "2", "1", "", "106", "1", "2", "64", "8", "2", "2", "1", "500", "0", "70", "2", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "0", "", "0005", "", "", "", "", "", "", "", "", "88.4", "98.4", "", "", "", "", "96.5"]} -{"pcdb_id": 16785, "brand_name": "Rotex", "model_name": "GSU 535-e", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 81.4, "comparative_hot_water_efficiency_pct": 36.5, "output_kw_max": 35.0, "final_year_of_manufacture": null, "raw": ["016785", "000246", "0", "2024/Jan/31 10:17", "Rotex Heating Systems", "Rotex", "GSU 535-e", "", "", "2007", "current", "1", "1", "1", "2", "0", "", "", "2", "3", "2", "35", "35", "", "", "88.1", "81.4", "", "36.5", "", "2", "", "", "106", "1", "2", "85", "8", "2", "2", "1", "500", "0", "70", "2", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "0", "", "0005", "", "", "", "", "", "", "", "", "86.7", "97.6", "", "", "", "", "95.5"]} -{"pcdb_id": 16786, "brand_name": "Rotex", "model_name": "GSU 535F-e", "model_qualifier": "", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 82.4, "comparative_hot_water_efficiency_pct": 37.0, "output_kw_max": 35.0, "final_year_of_manufacture": null, "raw": ["016786", "000246", "0", "2024/Jan/31 10:17", "Rotex Heating Systems", "Rotex", "GSU 535F-e", "", "", "2007", "current", "2", "1", "1", "2", "0", "", "", "2", "3", "2", "35", "35", "", "", "89.1", "82.4", "", "37.0", "", "2", "1", "", "106", "1", "2", "85", "8", "2", "2", "1", "500", "0", "70", "2", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "0", "", "0005", "", "", "", "", "", "", "", "", "88.6", "99.7", "", "", "", "", "97.6"]} -{"pcdb_id": 16787, "brand_name": "Potterton", "model_name": "Scottish Gas Potterton Precision", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 30.0, "final_year_of_manufacture": 2015, "raw": ["016787", "000005", "0", "2015/Aug/06 13:06", "Baxi Heating UK", "Potterton", "Scottish Gas Potterton Precision", "", "GC 41-592-33", "2001", "2015", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "30", "30", "", "", "88.1", "79.1", "", "57.8", "", "2", "", "", "102", "1", "2", "80", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.4", "96.5", "", "", "", "", "95.1"]} -{"pcdb_id": 16788, "brand_name": "Biasi", "model_name": "Activ A Plus", "model_qualifier": "16S", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 15.6, "final_year_of_manufacture": null, "raw": ["016788", "000208", "0", "2012/May/15 08:29", "Biasi UK", "Biasi", "Activ A Plus", "16S", "", "2011", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "15.6", "15.6", "", "", "89.0", "80.0", "", "58.4", "", "2", "1", "", "102", "1", "2", "94", "8.6", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.0", "98.9", "", "", "", "", "97.2"]} -{"pcdb_id": 16789, "brand_name": "Biasi", "model_name": "Activ A Plus", "model_qualifier": "16S", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 15.6, "final_year_of_manufacture": null, "raw": ["016789", "000208", "0", "2012/May/15 08:29", "Biasi UK", "Biasi", "Activ A Plus", "16S", "41-583-20", "2011", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "15.6", "15.6", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "94", "8.6", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "96.8", "", "", "", "", "95.1"]} -{"pcdb_id": 16790, "brand_name": "Biasi", "model_name": "Activ A Plus", "model_qualifier": "25S", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 19.5, "final_year_of_manufacture": null, "raw": ["016790", "000208", "0", "2012/May/15 08:29", "Biasi UK", "Biasi", "Activ A Plus", "25S", "41-583-21", "2011", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "19.5", "19.5", "", "", "89.1", "80.1", "", "58.5", "", "2", "1", "", "102", "1", "2", "102", "8.6", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.7", "99.2", "", "", "", "", "97.4"]} -{"pcdb_id": 16791, "brand_name": "Biasi", "model_name": "Activ A Plus", "model_qualifier": "25S", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 19.5, "final_year_of_manufacture": null, "raw": ["016791", "000208", "0", "2012/May/15 08:29", "Biasi UK", "Biasi", "Activ A Plus", "25S", "41-583-21", "2011", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "19.5", "19.5", "", "", "88.1", "79.1", "", "57.7", "", "2", "", "", "102", "1", "2", "102", "8.6", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "97.0", "", "", "", "", "95.3"]} -{"pcdb_id": 16792, "brand_name": "Biasi", "model_name": "Activ A Plus", "model_qualifier": "30C", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.4, "comparative_hot_water_efficiency_pct": 56.5, "output_kw_max": 24.4, "final_year_of_manufacture": null, "raw": ["016792", "000208", "0", "2013/Apr/08 09:56", "Biasi UK", "Biasi", "Activ A Plus", "30C", "47/583-26", "2011", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24.4", "24.4", "", "", "89.0", "80.4", "", "56.5", "", "2", "1", "", "104", "1", "2", "130", "8.6", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.3", "98.8", "", "", "", "", "97.2"]} -{"pcdb_id": 16793, "brand_name": "Biasi", "model_name": "Activ A Plus", "model_qualifier": "30C", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 86.8, "comparative_hot_water_efficiency_pct": 74.1, "output_kw_max": 24.4, "final_year_of_manufacture": null, "raw": ["016793", "000208", "0", "2012/May/15 08:30", "Biasi UK", "Biasi", "Activ A Plus", "30C", "47-583-26", "2011", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.4", "24.4", "", "", "88.0", "86.8", "", "74.1", "", "2", "", "", "104", "1", "2", "130", "8.6", "0", "", "", "", "0", "", "", "", "", "1", "7.104", "0.163", "0.002", "0.98571", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "96.7", "", "", "", "", "95.1"]} -{"pcdb_id": 16794, "brand_name": "Biasi", "model_name": "Activ A Plus", "model_qualifier": "35C", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.4, "comparative_hot_water_efficiency_pct": 56.6, "output_kw_max": 29.5, "final_year_of_manufacture": null, "raw": ["016794", "000208", "0", "2013/Apr/08 10:02", "Biasi (UK)", "Biasi", "Activ A Plus", "35C", "47-583-27", "2011", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "29.5", "29.5", "", "", "89.0", "80.4", "", "56.6", "", "2", "1", "", "104", "1", "2", "135", "8.6", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.4", "98.8", "", "", "", "", "97.2"]} -{"pcdb_id": 16795, "brand_name": "Biasi", "model_name": "Activ A Plus", "model_qualifier": "35C", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 86.8, "comparative_hot_water_efficiency_pct": 74.0, "output_kw_max": 29.5, "final_year_of_manufacture": null, "raw": ["016795", "000208", "0", "2011/Oct/11 14:34", "Biasi (UK)", "Biasi", "Activ A Plus", "35C", "47-583-27", "2011", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "29.5", "29.5", "", "", "88.0", "86.8", "", "74.0", "", "2", "", "", "104", "1", "2", "135", "8.6", "0", "", "", "", "0", "", "", "", "", "1", "7.12", "0.152", "0.002", "1.00577", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.5", "96.7", "", "", "", "", "95.1"]} -{"pcdb_id": 16796, "brand_name": "Potterton", "model_name": "Apollo", "model_qualifier": "30", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 55.9, "output_kw_max": 28.6, "final_year_of_manufacture": 2015, "raw": ["016796", "000005", "0", "2015/Aug/06 13:07", "Baxi Heating UK", "Potterton", "Apollo", "30", "GC No. 47-393-37", "2011", "2015", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28.6", "28.6", "", "", "88.1", "79.5", "", "55.9", "", "2", "", "", "104", "1", "2", "150", "3.5", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "88.0", "97.0", "", "", "", "", "95.3"]} -{"pcdb_id": 16797, "brand_name": "Potterton", "model_name": "Apollo", "model_qualifier": "25", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 56.1, "output_kw_max": 25.9, "final_year_of_manufacture": 2015, "raw": ["016797", "000005", "0", "2015/Aug/06 13:07", "Baxi Heating UK", "Potterton", "Apollo", "25", "GC No 47-393-38", "2011", "2015", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "25.9", "25.9", "", "", "88.4", "79.8", "", "56.1", "", "2", "", "", "104", "1", "2", "150", "3.5", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "89.7", "97.0", "", "", "", "", "95.7"]} -{"pcdb_id": 16798, "brand_name": "Firebird", "model_name": "Enviromax Heatpac", "model_qualifier": "C12/18 kW", "winter_efficiency_pct": 89.5, "summer_efficiency_pct": 81.7, "comparative_hot_water_efficiency_pct": 59.7, "output_kw_max": 18.0, "final_year_of_manufacture": null, "raw": ["016798", "000047", "0", "2012/Mar/27 10:12", "Firebird Boilers", "Firebird", "Enviromax Heatpac", "C12/18 kW", "", "2011", "current", "4", "1", "2", "1", "0", "", "", "2", "1", "1", "12", "18", "", "", "89.5", "81.7", "", "59.7", "", "2", "", "", "201", "1", "1", "38", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "92.7", "97.8", "", "", "", "", "96.8"]} -{"pcdb_id": 16799, "brand_name": "Firebird", "model_name": "Enviromax Popular", "model_qualifier": "C12/18KW", "winter_efficiency_pct": 89.5, "summer_efficiency_pct": 81.7, "comparative_hot_water_efficiency_pct": 59.7, "output_kw_max": 18.0, "final_year_of_manufacture": null, "raw": ["016799", "000047", "0", "2012/Mar/27 10:12", "Firebird Boilers", "Firebird", "Enviromax Popular", "C12/18KW", "", "2011", "current", "4", "1", "1", "1", "0", "", "", "2", "2", "1", "12", "18", "", "", "89.5", "81.7", "", "59.7", "", "2", "", "", "201", "1", "1", "38", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "92.7", "97.8", "", "", "", "", "96.8"]} -{"pcdb_id": 16801, "brand_name": "ATAG", "model_name": "XL70", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 60.1, "final_year_of_manufacture": null, "raw": ["016801", "000227", "0", "2013/Oct/23 12:58", "ATAG Verwarming Nederland BV", "ATAG", "XL70", "", "", "2011", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "60.1", "60.1", "", "", "88.8", "79.8", "", "58.3", "", "2", "", "", "102", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.7", "98.9", "", "", "", "", "96.8"]} -{"pcdb_id": 16804, "brand_name": "Vokera", "model_name": "Verve", "model_qualifier": "", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 45.78, "final_year_of_manufacture": null, "raw": ["016804", "000011", "0", "2012/Mar/27 10:12", "Vokera", "Vokera", "Verve", "", "4109475", "2001", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "45.78", "45.78", "", "", "88.2", "79.2", "", "57.8", "", "2", "", "", "102", "1", "2", "164", "4.5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "87.8", "97.3", "", "", "", "", "95.5"]} -{"pcdb_id": 16805, "brand_name": "Biasi", "model_name": "ActivA Plus", "model_qualifier": "25C", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 86.6, "comparative_hot_water_efficiency_pct": 74.1, "output_kw_max": 19.5, "final_year_of_manufacture": null, "raw": ["016805", "000208", "0", "2012/Feb/08 08:22", "Biasi", "Biasi", "ActivA Plus", "25C", "47-583-28", "2012", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "19.5", "19.5", "", "", "88.1", "86.6", "", "74.1", "", "2", "", "", "104", "1", "2", "102", "8.6", "0", "", "", "", "0", "", "", "", "", "1", "7.11", "0.15", "0.0", "0.98922", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "97.0", "", "", "", "", "95.3"]} -{"pcdb_id": 16806, "brand_name": "Biasi", "model_name": "ActivA Plus", "model_qualifier": "25C", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 56.6, "output_kw_max": 19.5, "final_year_of_manufacture": null, "raw": ["016806", "000208", "0", "2013/Apr/08 10:02", "Biasi UK", "Biasi", "ActivA Plus", "25C", "", "2012", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "19.5", "19.5", "", "", "89.1", "80.5", "", "56.6", "", "2", "1", "", "104", "1", "2", "102", "8.6", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.7", "99.2", "", "", "", "", "97.4"]} -{"pcdb_id": 16807, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "30 LXi System", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 30.0, "final_year_of_manufacture": 2012, "raw": ["016807", "000035", "0", "2020/Sep/08 10:25", "Worcester Bosch Group", "Worcester", "Greenstar", "30 LXi System", "41-406-11", "2012", "2012", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "30", "30", "", "", "88.3", "79.3", "", "57.9", "", "2", "", "", "102", "1", "2", "116", "1", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.2", "97.4", "", "", "", "", "95.7"]} -{"pcdb_id": 16808, "brand_name": "Pro", "model_name": "Procombi CT", "model_qualifier": "25", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 56.1, "output_kw_max": 19.5, "final_year_of_manufacture": null, "raw": ["016808", "000011", "0", "2012/Feb/02 15:21", "Vokera", "Pro", "Procombi CT", "25", "47 364 04", "2010", "current", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "19.5", "19.5", "", "", "88.4", "79.8", "", "56.1", "", "2", "", "", "104", "1", "2", "125", "4.5", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "97.8", "", "", "", "", "95.9"]} -{"pcdb_id": 16809, "brand_name": "Pro", "model_name": "Procombi CT", "model_qualifier": "29", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 56.0, "output_kw_max": 24.4, "final_year_of_manufacture": null, "raw": ["016809", "000011", "0", "2012/Feb/02 15:21", "Vokera", "Pro", "Procombi CT", "29", "47 364 05", "2010", "current", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "24.4", "24.4", "", "", "88.3", "79.7", "", "56.0", "", "2", "", "", "104", "1", "2", "128", "4.5", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "97.6", "", "", "", "", "95.7"]} -{"pcdb_id": 16810, "brand_name": "Glow-worm", "model_name": "Betacom2 28", "model_qualifier": "", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 86.5, "comparative_hot_water_efficiency_pct": 73.5, "output_kw_max": 23.3, "final_year_of_manufacture": null, "raw": ["016810", "000207", "0", "2013/Jan/30 14:32", "Vaillant Industrial UK", "Glow-worm", "Betacom2 28", "", "GC No 47-019-17", "2012", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "23.3", "23.3", "", "", "87.9", "86.5", "", "73.5", "", "2", "", "", "104", "1", "2", "68", "6", "0", "", "", "", "0", "", "", "", "", "1", "7.169", "0.101", "0.0011", "1.03013", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.4", "96.7", "", "", "", "", "94.9"]} -{"pcdb_id": 16811, "brand_name": "Glow-worm", "model_name": "Betacom2 28", "model_qualifier": "", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 56.4, "output_kw_max": 23.3, "final_year_of_manufacture": null, "raw": ["016811", "000207", "0", "2013/Jan/30 14:31", "Vaillant Industrial UK", "Glow-worm", "Betacom2 28", "", "", "2012", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "23.3", "23.3", "", "", "88.9", "80.3", "", "56.4", "", "2", "1", "", "104", "1", "2", "68", "6", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.3", "98.8", "", "", "", "", "97.0"]} -{"pcdb_id": 16812, "brand_name": "Glow-worm", "model_name": "Easicom 28", "model_qualifier": "", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 86.5, "comparative_hot_water_efficiency_pct": 73.5, "output_kw_max": 23.3, "final_year_of_manufacture": null, "raw": ["016812", "000207", "0", "2013/Jan/30 14:46", "Vaillant Industrial UK", "Glow-worm", "Easicom 28", "", "GC No 47-019-19", "2012", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "23.3", "23.3", "", "", "87.9", "86.5", "", "73.5", "", "2", "", "", "104", "1", "2", "68", "6", "0", "", "", "", "0", "", "", "", "", "1", "7.169", "0.101", "0.0011", "1.03013", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.4", "96.7", "", "", "", "", "94.9"]} -{"pcdb_id": 16813, "brand_name": "Glow-worm", "model_name": "Easicom 28", "model_qualifier": "", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 56.4, "output_kw_max": 23.3, "final_year_of_manufacture": null, "raw": ["016813", "000207", "0", "2013/Jan/30 14:46", "Vaillant Industrial UK", "Glow-worm", "Easicom 28", "", "", "2012", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "23.3", "23.3", "", "", "88.9", "80.3", "", "56.4", "", "2", "1", "", "104", "1", "2", "68", "6", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.3", "98.8", "", "", "", "", "97.0"]} -{"pcdb_id": 16814, "brand_name": "Glow-worm", "model_name": "Betacom2 24", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 86.6, "comparative_hot_water_efficiency_pct": 73.5, "output_kw_max": 18.0, "final_year_of_manufacture": null, "raw": ["016814", "000207", "0", "2013/Jan/30 14:30", "Vaillant Industrial UK", "Glow-worm", "Betacom2 24", "", "GC No 47-019-16", "2012", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "18", "18", "", "", "88.4", "86.6", "", "73.5", "", "2", "", "", "104", "1", "2", "68", "6", "0", "", "", "", "0", "", "", "", "", "1", "7.168", "0.101", "0.0019", "1.03651", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "97.8", "", "", "", "", "95.9"]} -{"pcdb_id": 16815, "brand_name": "Glow-worm", "model_name": "Betacom2 24", "model_qualifier": "", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 56.8, "output_kw_max": 18.0, "final_year_of_manufacture": null, "raw": ["016815", "000207", "0", "2013/Jan/30 14:30", "Vaillant Industrial UK", "Glow-worm", "Betacom2 24", "", "", "2012", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "18", "18", "", "", "89.4", "80.8", "", "56.8", "", "2", "1", "", "104", "1", "2", "68", "6", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.8", "99.9", "", "", "", "", "98.0"]} -{"pcdb_id": 16816, "brand_name": "Glow-worm", "model_name": "Easicom 24", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 86.6, "comparative_hot_water_efficiency_pct": 73.5, "output_kw_max": 18.0, "final_year_of_manufacture": null, "raw": ["016816", "000207", "0", "2013/Jan/30 14:45", "Vaillant Industrial UK", "Glow-worm", "Easicom 24", "", "GC No 47-019-18", "2012", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "18", "18", "", "", "88.4", "86.6", "", "73.5", "", "2", "", "", "104", "1", "2", "68", "6", "0", "", "", "", "0", "", "", "", "", "1", "7.168", "0.101", "0.0019", "1.03651", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "97.8", "", "", "", "", "95.9"]} -{"pcdb_id": 16817, "brand_name": "Glow-worm", "model_name": "Easicom 24", "model_qualifier": "", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 56.8, "output_kw_max": 18.0, "final_year_of_manufacture": null, "raw": ["016817", "000207", "0", "2013/Jan/30 14:45", "Vaillant Industrial UK", "Glow-worm", "Easicom 24", "", "", "2012", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "18", "18", "", "", "89.4", "80.8", "", "56.8", "", "2", "1", "", "104", "1", "2", "68", "6", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.8", "99.9", "", "", "", "", "98.0"]} -{"pcdb_id": 16818, "brand_name": "Sime", "model_name": "Murelle HE", "model_qualifier": "35 R M", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 33.8, "final_year_of_manufacture": 2018, "raw": ["016818", "000213", "0", "2018/Mar/05 16:58", "Fonderie Sime S.p.A.", "Sime", "Murelle HE", "35 R M", "", "2011", "2018", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "33.8", "33.8", "", "", "88.5", "79.5", "", "58.1", "", "2", "", "", "102", "1", "2", "105", "4.6", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "98.1", "", "", "", "", "96.2"]} -{"pcdb_id": 16819, "brand_name": "Sime", "model_name": "Murelle HE", "model_qualifier": "35R M", "winter_efficiency_pct": 89.5, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 58.8, "output_kw_max": 33.8, "final_year_of_manufacture": 2018, "raw": ["016819", "000213", "0", "2018/Mar/07 09:47", "Fonderie Sime S.p.A.", "Sime", "Murelle HE", "35R M", "", "2011", "2018", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "33.8", "33.8", "", "", "89.5", "80.5", "", "58.8", "", "2", "1", "", "102", "1", "2", "105", "4.6", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.7", "100.3", "", "", "", "", "98.3"]} -{"pcdb_id": 16820, "brand_name": "Sime", "model_name": "Murelle HE 50R M", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 46.8, "final_year_of_manufacture": 2018, "raw": ["016820", "000213", "0", "2018/Jul/11 10:04", "Fonderie Sime S.p.A.", "Sime", "Murelle HE 50R M", "", "", "2011", "2018", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "46.8", "46.8", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "130", "4.4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.1", "97.8", "", "", "", "", "95.9"]} -{"pcdb_id": 16821, "brand_name": "Sime", "model_name": "Murelle HE", "model_qualifier": "50R M", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 80.4, "comparative_hot_water_efficiency_pct": 58.7, "output_kw_max": 46.8, "final_year_of_manufacture": 2018, "raw": ["016821", "000213", "0", "2018/Mar/07 10:13", "Fonderie Sime S.p.A.", "Sime", "Murelle HE", "50R M", "", "2011", "2018", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "46.8", "46.8", "", "", "89.4", "80.4", "", "58.7", "", "2", "1", "", "102", "1", "2", "130", "4.4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.1", "99.9", "", "", "", "", "98.1"]} -{"pcdb_id": 16822, "brand_name": "Ideal", "model_name": "LOGIC COMBI", "model_qualifier": "EC35", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 74.2, "output_kw_max": 24.2, "final_year_of_manufacture": 2013, "raw": ["016822", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "LOGIC COMBI", "EC35", "47-348-96", "2012", "2013", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "88.3", "87.3", "", "74.2", "", "2", "", "", "104", "1", "2", "177", "1", "0", "", "", "", "0", "", "", "", "", "1", "7.0952", "0.1707", "0.0089", "0.97663", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.8", "96.9", "", "", "", "", "95.5"]} -{"pcdb_id": 16823, "brand_name": "Ideal", "model_name": "LOGIC COMBI", "model_qualifier": "EC30", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 73.2, "output_kw_max": 24.2, "final_year_of_manufacture": 2013, "raw": ["016823", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "LOGIC COMBI", "EC30", "47-348-95", "2012", "2013", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "88.4", "87.3", "", "73.2", "", "2", "", "", "104", "1", "2", "152", "1", "0", "", "", "", "0", "", "", "", "", "1", "7.1946", "0.1567", "0.0183", "1.0224", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.0", "96.9", "", "", "", "", "95.6"]} -{"pcdb_id": 16824, "brand_name": "Ideal", "model_name": "LOGIC COMBI", "model_qualifier": "EC24", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 72.6, "output_kw_max": 24.2, "final_year_of_manufacture": 2013, "raw": ["016824", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "LOGIC COMBI", "EC24", "47-348-94", "2012", "2013", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "88.4", "87.3", "", "72.6", "", "2", "", "", "104", "1", "2", "146", "1", "0", "", "", "", "0", "", "", "", "", "1", "7.2565", "0.1564", "0.0157", "1.09285", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.8", "96.9", "", "", "", "", "95.6"]} -{"pcdb_id": 16825, "brand_name": "The White Boiler Company", "model_name": "WH100 (T)", "model_qualifier": "", "winter_efficiency_pct": 89.3, "summer_efficiency_pct": 80.7, "comparative_hot_water_efficiency_pct": 56.8, "output_kw_max": 24.1, "final_year_of_manufacture": null, "raw": ["016825", "000270", "0", "2013/Apr/08 10:02", "The White Boiler Company", "The White Boiler Company", "WH100 (T)", "", "", "2011", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24.1", "24.1", "", "", "89.3", "80.7", "", "56.8", "", "2", "1", "", "104", "1", "2", "160", "3", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.4", "99.6", "", "", "", "", "97.8"]} -{"pcdb_id": 16826, "brand_name": "The White Boiler Company", "model_name": "WH100 (T)", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 86.8, "comparative_hot_water_efficiency_pct": 67.3, "output_kw_max": 24.1, "final_year_of_manufacture": null, "raw": ["016826", "000270", "0", "2012/Oct/26 10:48", "The White Boiler Company", "The White Boiler Company", "WH100 (T)", "", "", "2011", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.1", "24.1", "", "", "88.3", "86.8", "", "67.3", "", "2", "", "", "104", "1", "2", "160", "3", "0", "", "", "", "0", "", "", "", "", "1", "7.8249", "0.127", "0.0052", "1.66676", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.5", "97.4", "", "", "", "", "95.7"]} -{"pcdb_id": 16827, "brand_name": "The White Boiler Company", "model_name": "WH130 (T)", "model_qualifier": "", "winter_efficiency_pct": 89.3, "summer_efficiency_pct": 80.7, "comparative_hot_water_efficiency_pct": 56.8, "output_kw_max": 29.0, "final_year_of_manufacture": null, "raw": ["016827", "000270", "0", "2013/Apr/08 10:03", "The White Boiler Company", "The White Boiler Company", "WH130 (T)", "", "", "2011", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "29", "29", "", "", "89.3", "80.7", "", "56.8", "", "2", "1", "", "104", "1", "2", "160", "3", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.3", "99.7", "", "", "", "", "97.9"]} -{"pcdb_id": 16828, "brand_name": "The White Boiler Company", "model_name": "WH130 (T)", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 86.8, "comparative_hot_water_efficiency_pct": 67.0, "output_kw_max": 29.0, "final_year_of_manufacture": null, "raw": ["016828", "000270", "0", "2012/Oct/26 10:48", "The White Boiler Company", "The White Boiler Company", "WH130 (T)", "", "", "2011", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "29", "29", "", "", "88.3", "86.8", "", "67.0", "", "2", "", "", "104", "1", "2", "160", "3", "0", "", "", "", "0", "", "", "", "", "1", "7.8551", "0.1118", "0.0049", "1.6922", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "97.5", "", "", "", "", "95.7"]} -{"pcdb_id": 16829, "brand_name": "The White Boiler Company", "model_name": "WH Regular 6-24 (T)", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 24.1, "final_year_of_manufacture": null, "raw": ["016829", "000270", "0", "2012/Apr/27 14:47", "The White Boiler Company", "The White Boiler Company", "WH Regular 6-24 (T)", "", "", "2011", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24.1", "24.1", "", "", "88.3", "79.3", "", "57.9", "", "2", "", "", "102", "1", "2", "160", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.5", "97.4", "", "", "", "", "95.7"]} -{"pcdb_id": 16830, "brand_name": "The White Boiler Company", "model_name": "WH Regular 9-32 (T)", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 29.0, "final_year_of_manufacture": null, "raw": ["016830", "000270", "0", "2012/Apr/27 14:46", "The White Boiler Company", "The White Boiler Company", "WH Regular 9-32 (T)", "", "", "2011", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "29", "29", "", "", "88.3", "79.3", "", "57.9", "", "2", "", "", "102", "1", "2", "160", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "97.5", "", "", "", "", "95.7"]} -{"pcdb_id": 16831, "brand_name": "The White Boiler Company", "model_name": "WH System 6-24 (T)", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 24.1, "final_year_of_manufacture": null, "raw": ["016831", "000270", "0", "2012/Apr/27 14:46", "The White Boiler Company", "The White Boiler Company", "WH System 6-24 (T)", "", "", "2011", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24.1", "24.1", "", "", "88.3", "79.3", "", "57.9", "", "2", "", "", "102", "1", "2", "160", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.5", "97.4", "", "", "", "", "95.7"]} -{"pcdb_id": 16832, "brand_name": "The White Boiler Company", "model_name": "WH System 9-32 (T)", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 29.0, "final_year_of_manufacture": null, "raw": ["016832", "000270", "0", "2012/Apr/27 14:46", "The White Boiler Company", "The White Boiler Company", "WH System 9-32 (T)", "", "", "2011", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "29.0", "29.0", "", "", "88.3", "79.3", "", "57.9", "", "2", "", "", "102", "1", "2", "160", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "97.5", "", "", "", "", "95.7"]} -{"pcdb_id": 16833, "brand_name": "Vaillant", "model_name": "ecoTEC plus 637", "model_qualifier": "VU GB 376/5-5", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 37.0, "final_year_of_manufacture": 2015, "raw": ["016833", "000031", "0", "2012/May/01 13:29", "Vaillant", "Vaillant", "ecoTEC plus 637", "VU GB 376/5-5", "GC 41-044-65", "2012", "2015", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "37", "37", "", "", "88.5", "79.5", "", "58.1", "", "2", "", "", "102", "1", "2", "130", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0045", "", "", "", "", "", "", "", "", "88.8", "97.8", "", "", "", "", "96.1"]} -{"pcdb_id": 16834, "brand_name": "Vaillant", "model_name": "ecoTEC plus 630", "model_qualifier": "VU GB 306/5-5", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 30.0, "final_year_of_manufacture": 2015, "raw": ["016834", "000031", "0", "2012/May/30 09:07", "Vaillant", "Vaillant", "ecoTEC plus 630", "VU GB 306/5-5", "GC 41-044-64", "2012", "2015", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "30", "30", "", "", "88.7", "79.7", "", "58.2", "", "2", "", "", "102", "1", "2", "110", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0045", "", "", "", "", "", "", "", "", "88.7", "98.2", "", "", "", "", "96.4"]} -{"pcdb_id": 16835, "brand_name": "Vaillant", "model_name": "ecoTEC plus 624", "model_qualifier": "VU GB 246/5-5", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 24.0, "final_year_of_manufacture": 2015, "raw": ["016835", "000031", "0", "2012/May/30 09:07", "Vaillant", "Vaillant", "ecoTEC plus 624", "VU GB 246/5-5", "GC 41-044-63", "2012", "2015", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24", "24", "", "", "88.7", "79.7", "", "58.2", "", "2", "", "", "102", "1", "2", "100", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0045", "", "", "", "", "", "", "", "", "89.0", "98.2", "", "", "", "", "96.5"]} -{"pcdb_id": 16836, "brand_name": "Vaillant", "model_name": "ecoTEC plus 618", "model_qualifier": "VU GB 186/5-5", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 18.0, "final_year_of_manufacture": 2015, "raw": ["016836", "000031", "0", "2012/Apr/27 14:33", "Vaillant", "Vaillant", "ecoTEC plus 618", "VU GB 186/5-5", "GC 41-044-62", "2012", "2015", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18", "18", "", "", "88.6", "79.6", "", "58.2", "", "2", "", "", "102", "1", "2", "100", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0045", "", "", "", "", "", "", "", "", "89.5", "97.8", "", "", "", "", "96.2"]} -{"pcdb_id": 16837, "brand_name": "Vaillant", "model_name": "ecoTEC plus 615", "model_qualifier": "VU GB 156/5-5", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 15.0, "final_year_of_manufacture": 2015, "raw": ["016837", "000031", "0", "2012/Apr/27 14:32", "Vaillant", "Vaillant", "ecoTEC plus 615", "VU GB 156/5-5", "GC 41-044-61", "2012", "2015", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "15", "15", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "95", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0045", "", "", "", "", "", "", "", "", "89.4", "97.3", "", "", "", "", "95.8"]} -{"pcdb_id": 16838, "brand_name": "Vaillant", "model_name": "ecoTEC plus 612", "model_qualifier": "VU GB 126/5-5", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 12.0, "final_year_of_manufacture": 2015, "raw": ["016838", "000031", "0", "2012/Apr/27 14:32", "Vaillant", "Vaillant", "ecoTEC plus 612", "VU GB 126/5-5", "GC 41-044-60", "2012", "2015", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "12", "12", "", "", "88.3", "79.3", "", "57.9", "", "2", "", "", "102", "1", "2", "90", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0045", "", "", "", "", "", "", "", "", "88.7", "97.3", "", "", "", "", "95.7"]} -{"pcdb_id": 16839, "brand_name": "Vaillant", "model_name": "ecoTEC pro 28", "model_qualifier": "VUW GB 286/5-3", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 87.0, "comparative_hot_water_efficiency_pct": 75.1, "output_kw_max": 24.4, "final_year_of_manufacture": 2015, "raw": ["016839", "000031", "0", "2019/Mar/04 10:28", "Vaillant", "Vaillant", "ecoTEC pro 28", "VUW GB 286/5-3", "GC 47-044-45", "2005", "2015", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.4", "24.4", "", "", "88.7", "87.0", "", "75.1", "", "2", "", "", "104", "1", "2", "105", "2", "0", "", "", "", "0", "", "", "", "", "1", "7.012", "0.133", "0.0025", "0.91251", "", "", "", "", "", "1", "1", "", "0045", "", "", "", "", "", "", "", "", "89.0", "98.0", "", "", "", "", "96.3"]} -{"pcdb_id": 16840, "brand_name": "Vaillant", "model_name": "ecoTEC pro 24", "model_qualifier": "VUW GB 246/5-3", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 87.0, "comparative_hot_water_efficiency_pct": 76.3, "output_kw_max": 18.9, "final_year_of_manufacture": 2015, "raw": ["016840", "000031", "0", "2019/Mar/04 10:26", "Vaillant", "Vaillant", "ecoTEC pro 24", "VUW GB 246/5-3", "GC 47-044-44", "2005", "2015", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "18.9", "18.9", "", "", "88.5", "87.0", "", "76.3", "", "2", "", "", "104", "1", "2", "105", "2", "0", "", "", "", "0", "", "", "", "", "1", "6.904", "0.129", "0.003", "0.80529", "", "", "", "", "", "1", "1", "", "0045", "", "", "", "", "", "", "", "", "89.0", "97.8", "", "", "", "", "96.1"]} -{"pcdb_id": 16841, "brand_name": "Vaillant", "model_name": "ecoTEC plus 824", "model_qualifier": "VUW GB 246/5-5", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 87.0, "comparative_hot_water_efficiency_pct": 76.1, "output_kw_max": 19.3, "final_year_of_manufacture": 2015, "raw": ["016841", "000031", "0", "2019/Mar/04 10:13", "Vaillant", "Vaillant", "ecoTEC plus 824", "VUW GB 246/5-5", "GC 47-044-40", "2005", "2015", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "19.3", "19.3", "", "", "88.5", "87.0", "", "76.1", "", "2", "", "", "104", "1", "2", "105", "2", "0", "", "", "", "0", "", "", "", "", "1", "6.923", "0.12", "0.003", "0.81911", "", "", "", "", "", "1", "1", "", "0045", "", "", "", "", "", "", "", "", "88.8", "97.8", "", "", "", "", "96.1"]} -{"pcdb_id": 16842, "brand_name": "Vaillant", "model_name": "ecoTEC plus 831", "model_qualifier": "VUW GB 316/5-5", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 87.0, "comparative_hot_water_efficiency_pct": 74.4, "output_kw_max": 24.4, "final_year_of_manufacture": 2015, "raw": ["016842", "000031", "0", "2019/Mar/04 10:15", "Vaillant", "Vaillant", "ecoTEC plus 831", "VUW GB 316/5-5", "GC 47-044-41", "2005", "2015", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.4", "24.4", "", "", "88.7", "87.0", "", "74.4", "", "2", "", "", "104", "1", "2", "105", "2", "0", "", "", "", "0", "", "", "", "", "1", "7.074", "0.119", "0.003", "0.96947", "", "", "", "", "", "", "", "", "0045", "", "", "", "", "", "", "", "", "89.0", "98.2", "", "", "", "", "96.5"]} -{"pcdb_id": 16843, "brand_name": "Vaillant", "model_name": "ecoTEC plus 837", "model_qualifier": "VUW GB 376/5-5", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 87.0, "comparative_hot_water_efficiency_pct": 73.9, "output_kw_max": 28.6, "final_year_of_manufacture": 2015, "raw": ["016843", "000031", "0", "2019/Mar/04 10:19", "Vaillant", "Vaillant", "ecoTEC plus 837", "VUW GB 376/5-5", "GC 47-044-42", "2005", "2015", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28.6", "28.6", "", "", "88.7", "87.0", "", "73.9", "", "2", "", "", "104", "1", "2", "130", "2", "0", "", "", "", "0", "", "", "", "", "1", "7.122", "0.126", "0.003", "1.01583", "", "", "", "", "", "1", "1", "", "0045", "", "", "", "", "", "", "", "", "89.0", "98.2", "", "", "", "", "96.5"]} -{"pcdb_id": 16844, "brand_name": "Vaillant", "model_name": "ecoTEC pro 28", "model_qualifier": "VUW GB 286/5-3", "winter_efficiency_pct": 89.7, "summer_efficiency_pct": 81.1, "comparative_hot_water_efficiency_pct": 63.3, "output_kw_max": 24.4, "final_year_of_manufacture": 2015, "raw": ["016844", "000031", "0", "2013/Apr/08 10:03", "Vaillant", "Vaillant", "ecoTEC pro 28", "VUW GB 286/5-3", "GC 47-044-47", "2005", "2015", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24.4", "24.4", "", "", "89.7", "81.1", "", "63.3", "", "2", "1", "0", "104", "1", "2", "105", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "", "0045", "", "", "", "", "", "", "", "", "91.0", "100.2", "", "", "", "", "98.5"]} -{"pcdb_id": 16845, "brand_name": "Vaillant", "model_name": "ecoTEC plus 630", "model_qualifier": "VU GB 306/5-5", "winter_efficiency_pct": 89.7, "summer_efficiency_pct": 80.7, "comparative_hot_water_efficiency_pct": 58.9, "output_kw_max": 30.4, "final_year_of_manufacture": 2015, "raw": ["016845", "000031", "0", "2012/May/30 09:06", "Vaillant", "Vaillant", "ecoTEC plus 630", "VU GB 306/5-5", "GC 47-044-67", "2005", "2015", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "30.4", "30.4", "", "", "89.7", "80.7", "", "58.9", "", "2", "1", "", "102", "1", "2", "110", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0045", "", "", "", "", "", "", "", "", "90.7", "100.4", "", "", "", "", "98.6"]} -{"pcdb_id": 16846, "brand_name": "Vaillant", "model_name": "ecoTEC plus 831", "model_qualifier": "VUW GB 316/5-5", "winter_efficiency_pct": 89.7, "summer_efficiency_pct": 81.1, "comparative_hot_water_efficiency_pct": 63.3, "output_kw_max": 24.4, "final_year_of_manufacture": 2015, "raw": ["016846", "000031", "0", "2013/Apr/08 10:04", "Vaillant", "Vaillant", "ecoTEC plus 831", "VUW GB 316/5-5", "GC 47-044-41", "2005", "2015", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24.4", "24.4", "", "", "89.7", "81.1", "", "63.3", "", "2", "1", "", "104", "1", "2", "105", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "", "0045", "", "", "", "", "", "", "", "", "91.0", "100.4", "", "", "", "", "98.6"]} -{"pcdb_id": 16847, "brand_name": "Vaillant", "model_name": "ecoTEC plus 618", "model_qualifier": "VU GB 186/5-5", "winter_efficiency_pct": 89.6, "summer_efficiency_pct": 80.6, "comparative_hot_water_efficiency_pct": 58.9, "output_kw_max": 18.5, "final_year_of_manufacture": 2015, "raw": ["016847", "000031", "0", "2012/May/28 10:46", "Vaillant", "Vaillant", "ecoTEC plus 618", "VU GB 186/5-5", "GC 41-044-66", "2005", "2015", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "18.5", "18.5", "", "", "89.6", "80.6", "", "58.9", "", "2", "1", "", "102", "1", "2", "100", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0045", "", "", "", "", "", "", "", "", "91.5", "99.9", "", "", "", "", "98.3"]} -{"pcdb_id": 16848, "brand_name": "Ideal", "model_name": "Esprit Eco", "model_qualifier": "24", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 62.2, "output_kw_max": 24.2, "final_year_of_manufacture": null, "raw": ["016848", "000008", "0", "2012/Aug/28 09:53", "Ideal Boilers", "Ideal", "Esprit Eco", "24", "47-348-91", "2012", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "88.3", "79.7", "", "62.2", "", "2", "", "", "104", "1", "2", "146", "1", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "", "0035", "", "", "", "", "", "", "", "", "89.8", "96.9", "", "", "", "", "95.5"]} -{"pcdb_id": 16849, "brand_name": "Ideal", "model_name": "Esprit Eco", "model_qualifier": "30", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 62.3, "output_kw_max": 24.2, "final_year_of_manufacture": null, "raw": ["016849", "000008", "0", "2012/Aug/28 09:53", "Ideal Boilers", "Ideal", "Esprit Eco", "30", "47-348-92", "2012", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "88.4", "79.8", "", "62.3", "", "2", "", "", "104", "1", "2", "152", "1", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "", "0035", "", "", "", "", "", "", "", "", "90.0", "96.9", "", "", "", "", "95.6"]} -{"pcdb_id": 16850, "brand_name": "Vaillant", "model_name": "ecoTEC plus 937", "model_qualifier": "VUI GB 376/5-5", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 87.0, "comparative_hot_water_efficiency_pct": 65.8, "output_kw_max": 28.6, "final_year_of_manufacture": 2015, "raw": ["016850", "000031", "0", "2019/Mar/04 10:22", "Vaillant", "Vaillant", "ecoTEC plus 937", "VUI GB 376/5-5", "GC 47-044-43", "2005", "2015", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28.6", "28.6", "", "", "88.7", "87.0", "", "65.8", "", "2", "", "", "104", "1", "2", "130", "2", "0", "", "", "", "0", "", "", "", "", "1", "7.998", "0.214", "0.0", "1.8794", "", "", "", "", "", "1", "1", "", "0045", "", "", "", "", "", "", "", "", "89.0", "98.2", "", "", "", "", "96.5"]} -{"pcdb_id": 16851, "brand_name": "The White Boiler Company", "model_name": "CSE30 (T)", "model_qualifier": "", "winter_efficiency_pct": 89.3, "summer_efficiency_pct": 80.7, "comparative_hot_water_efficiency_pct": 56.8, "output_kw_max": 24.1, "final_year_of_manufacture": null, "raw": ["016851", "000270", "0", "2013/Apr/08 10:04", "The White Boiler Company", "The White Boiler Company", "CSE30 (T)", "", "", "2001", "current", "2", "2", "1", "2", "1", "", "", "2", "2", "2", "24.1", "24.1", "", "", "89.3", "80.7", "", "56.8", "", "2", "1", "", "104", "1", "2", "160", "3", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.4", "99.6", "", "", "", "", "97.8"]} -{"pcdb_id": 16852, "brand_name": "The White Boiler Company", "model_name": "CSE30 (T)", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 86.8, "comparative_hot_water_efficiency_pct": 75.3, "output_kw_max": 24.1, "final_year_of_manufacture": null, "raw": ["016852", "000270", "0", "2012/May/28 10:32", "The White Boiler Company", "The White Boiler Company", "CSE30 (T)", "", "", "2011", "current", "1", "2", "1", "2", "1", "", "", "2", "2", "2", "24.1", "24.1", "", "", "88.3", "86.8", "", "75.3", "", "2", "", "", "104", "1", "2", "160", "3", "0", "", "", "", "0", "", "", "", "", "1", "6.9896", "0.1252", "0.0049", "0.86314", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.5", "97.4", "", "", "", "", "95.7"]} -{"pcdb_id": 16853, "brand_name": "Remeha", "model_name": "Avanta Exclusive", "model_qualifier": "39c", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 56.6, "output_kw_max": 34.8, "final_year_of_manufacture": null, "raw": ["016853", "000005", "0", "2012/Sep/27 15:40", "Remeha", "Remeha", "Avanta Exclusive", "39c", "", "2012", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "34.8", "34.8", "", "", "89.1", "80.5", "", "56.6", "", "2", "", "", "104", "1", "2", "180", "3", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "99.6", "", "", "", "", "97.4"]} -{"pcdb_id": 16854, "brand_name": "Remeha", "model_name": "Avanta Exclusive", "model_qualifier": "35c", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 56.5, "output_kw_max": 29.5, "final_year_of_manufacture": null, "raw": ["016854", "000005", "0", "2012/Sep/27 15:40", "Remeha", "Remeha", "Avanta Exclusive", "35c", "", "2012", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "29.5", "29.5", "", "", "88.9", "80.3", "", "56.5", "", "2", "", "", "104", "1", "2", "115", "3", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.5", "98.8", "", "", "", "", "96.9"]} -{"pcdb_id": 16855, "brand_name": "Remeha", "model_name": "Avanta Exclusive", "model_qualifier": "28c", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 56.2, "output_kw_max": 22.0, "final_year_of_manufacture": null, "raw": ["016855", "000005", "0", "2012/Sep/27 15:40", "Remeha", "Remeha", "Avanta Exclusive", "28c", "", "2012", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "22", "22", "", "", "88.5", "79.9", "", "56.2", "", "2", "", "", "104", "1", "2", "115", "3", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.6", "97.9", "", "", "", "", "96.2"]} -{"pcdb_id": 16856, "brand_name": "HRM", "model_name": "Wallstar", "model_qualifier": "20/24 Condensing A", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 81.2, "comparative_hot_water_efficiency_pct": 59.3, "output_kw_max": 24.0, "final_year_of_manufacture": null, "raw": ["016856", "000098", "0", "2012/May/30 09:10", "HRM Boilers", "HRM", "Wallstar", "20/24 Condensing A", "", "2010", "current", "4", "2", "1", "1", "0", "", "", "2", "2", "2", "20", "24", "", "", "89.0", "81.2", "", "59.3", "", "2", "", "", "201", "1", "1", "110", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "92.6", "96.7", "", "", "", "", "95.9"]} -{"pcdb_id": 16857, "brand_name": "Biasi", "model_name": "Advance Plus", "model_qualifier": "16S", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 15.6, "final_year_of_manufacture": null, "raw": ["016857", "000208", "0", "2012/Jun/28 11:09", "Biasi UK", "Biasi", "Advance Plus", "16S", "41-583-22", "2012", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "15.6", "15.6", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "94", "8.6", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "96.8", "", "", "", "", "95.1"]} -{"pcdb_id": 16858, "brand_name": "Biasi", "model_name": "Advance Plus", "model_qualifier": "16S", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 15.6, "final_year_of_manufacture": null, "raw": ["016858", "000208", "0", "2012/May/22 11:59", "Biasi UK", "Biasi", "Advance Plus", "16S", "", "2012", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "15.6", "15.6", "", "", "89.0", "80.0", "", "58.4", "", "2", "1", "", "102", "1", "2", "94", "8.6", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.0", "98.9", "", "", "", "", "97.2"]} -{"pcdb_id": 16859, "brand_name": "Biasi", "model_name": "Advance Plus", "model_qualifier": "25C", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 86.6, "comparative_hot_water_efficiency_pct": 74.1, "output_kw_max": 19.5, "final_year_of_manufacture": null, "raw": ["016859", "000208", "0", "2012/Jun/28 11:09", "Biasi UK", "Biasi", "Advance Plus", "25C", "47-583-29", "2012", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "19.5", "19.5", "", "", "88.1", "86.6", "", "74.1", "", "2", "", "", "104", "1", "2", "102", "8.6", "0", "", "", "", "0", "", "", "", "", "1", "7.11", "0.149", "0.0", "0.98922", "", "", "", "", "", "1", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "97.0", "", "", "", "", "95.3"]} -{"pcdb_id": 16860, "brand_name": "Biasi", "model_name": "Advance Plus", "model_qualifier": "25C", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 56.6, "output_kw_max": 19.5, "final_year_of_manufacture": null, "raw": ["016860", "000208", "0", "2013/Apr/08 10:04", "Biasi UK", "Biasi", "Advance Plus", "25C", "", "2012", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "19.5", "19.5", "", "", "89.1", "80.5", "", "56.6", "", "2", "1", "", "104", "1", "2", "102", "8.6", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "0", "", "0005", "", "", "", "", "", "", "", "", "89.7", "99.2", "", "", "", "", "97.4"]} -{"pcdb_id": 16861, "brand_name": "Biasi", "model_name": "Advance Plus", "model_qualifier": "25S", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 24.4, "final_year_of_manufacture": null, "raw": ["016861", "000208", "0", "2012/Jun/28 11:09", "Biasi UK", "Biasi", "Advance Plus", "25S", "41-583-23", "2012", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24.4", "24.4", "", "", "88.1", "79.1", "", "57.7", "", "2", "", "", "102", "1", "2", "102", "8.6", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "97.0", "", "", "", "", "95.3"]} -{"pcdb_id": 16862, "brand_name": "Biasi", "model_name": "Advance Plus", "model_qualifier": "25S", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 24.4, "final_year_of_manufacture": null, "raw": ["016862", "000208", "0", "2012/May/22 12:01", "Biasi UK", "Biasi", "Advance Plus", "25S", "", "2012", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "24.4", "24.4", "", "", "89.1", "80.1", "", "58.5", "", "2", "1", "", "102", "1", "2", "102", "8.6", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.7", "99.2", "", "", "", "", "97.4"]} -{"pcdb_id": 16863, "brand_name": "Biasi", "model_name": "Advance Plus", "model_qualifier": "30C", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 86.8, "comparative_hot_water_efficiency_pct": 74.1, "output_kw_max": 24.4, "final_year_of_manufacture": null, "raw": ["016863", "000208", "0", "2012/Jun/28 11:10", "Biasi UK", "Biasi", "Advance Plus", "30C", "47-583-30", "2012", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.4", "24.4", "", "", "88.0", "86.8", "", "74.1", "", "2", "", "", "104", "1", "2", "130", "8.6", "0", "", "", "", "0", "", "", "", "", "1", "7.104", "0.163", "0.002", "0.98571", "", "", "", "", "", "1", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "96.7", "", "", "", "", "95.1"]} -{"pcdb_id": 16864, "brand_name": "Biasi", "model_name": "Advance Plus", "model_qualifier": "30C", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.4, "comparative_hot_water_efficiency_pct": 56.5, "output_kw_max": 24.4, "final_year_of_manufacture": null, "raw": ["016864", "000208", "0", "2013/Apr/08 10:05", "Biasi UK", "Biasi", "Advance Plus", "30C", "", "2012", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24.4", "24.4", "", "", "89.0", "80.4", "", "56.5", "", "2", "1", "", "104", "1", "2", "130", "8.6", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "0", "", "0005", "", "", "", "", "", "", "", "", "90.3", "98.8", "", "", "", "", "97.2"]} -{"pcdb_id": 16865, "brand_name": "Biasi", "model_name": "Advance Plus", "model_qualifier": "30S", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 27.5, "final_year_of_manufacture": null, "raw": ["016865", "000208", "0", "2012/Jun/28 11:10", "Biasi UK", "Biasi", "Advance Plus", "30S", "41-583-24", "2012", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "27.5", "27.5", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "102", "8.6", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.5", "96.7", "", "", "", "", "95.1"]} -{"pcdb_id": 16866, "brand_name": "Biasi", "model_name": "Advance Plus", "model_qualifier": "30S", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 27.5, "final_year_of_manufacture": null, "raw": ["016866", "000208", "0", "2012/May/22 12:02", "Biasi UK", "Biasi", "Advance Plus", "30S", "", "2012", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "27.5", "27.5", "", "", "89.0", "80.0", "", "58.5", "", "2", "1", "", "102", "1", "2", "102", "8.6", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.4", "98.8", "", "", "", "", "97.2"]} -{"pcdb_id": 16867, "brand_name": "Biasi", "model_name": "Advance Plus", "model_qualifier": "35C", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 86.8, "comparative_hot_water_efficiency_pct": 74.0, "output_kw_max": 29.5, "final_year_of_manufacture": null, "raw": ["016867", "000208", "0", "2012/Jun/28 11:10", "Biasi UK", "Biasi", "Advance Plus", "35C", "47-583-31", "2012", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "29.5", "29.5", "", "", "88.0", "86.8", "", "74.0", "", "2", "", "", "104", "1", "2", "135", "8.6", "0", "", "", "", "0", "", "", "", "", "1", "7.12", "0.152", "0.002", "1.00577", "", "", "", "", "", "1", "", "", "0005", "", "", "", "", "", "", "", "", "88.5", "96.7", "", "", "", "", "95.1"]} -{"pcdb_id": 16868, "brand_name": "Biasi", "model_name": "Advance Plus", "model_qualifier": "35C", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.4, "comparative_hot_water_efficiency_pct": 56.6, "output_kw_max": 29.5, "final_year_of_manufacture": null, "raw": ["016868", "000208", "0", "2013/Apr/08 10:05", "Biasi UK", "Biasi", "Advance Plus", "35C", "", "2012", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "29.5", "29.5", "", "", "89.0", "80.4", "", "56.6", "", "2", "1", "", "104", "1", "2", "135", "8.6", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "0", "", "0005", "", "", "", "", "", "", "", "", "90.4", "98.8", "", "", "", "", "97.2"]} -{"pcdb_id": 16869, "brand_name": "Biasi", "model_name": "Inovia", "model_qualifier": "25C", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 86.6, "comparative_hot_water_efficiency_pct": 74.1, "output_kw_max": 19.5, "final_year_of_manufacture": null, "raw": ["016869", "000208", "0", "2012/Jun/28 11:10", "Biasi UK", "Biasi", "Inovia", "25C", "47-583-32", "2012", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "19.5", "19.5", "", "", "88.1", "86.6", "", "74.1", "", "2", "", "", "104", "1", "2", "102", "8.6", "0", "", "", "", "0", "", "", "", "", "1", "7.11", "0.149", "0.0", "0.98922", "", "", "", "", "", "1", "1", "", "0005", "", "", "", "", "", "", "", "", "87.8", "97.0", "", "", "", "", "95.3"]} -{"pcdb_id": 16870, "brand_name": "Biasi", "model_name": "Inovia", "model_qualifier": "25C", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 62.8, "output_kw_max": 19.5, "final_year_of_manufacture": null, "raw": ["016870", "000208", "0", "2013/Apr/08 10:07", "Biasi UK", "Biasi", "Inovia", "25C", "", "2012", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "19.50", "19.50", "", "", "89.1", "80.5", "", "62.8", "", "2", "1", "", "104", "1", "2", "102", "8.6", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "", "0005", "", "", "", "", "", "", "", "", "89.7", "99.2", "", "", "", "", "97.4"]} -{"pcdb_id": 16871, "brand_name": "Biasi", "model_name": "Inovia", "model_qualifier": "25S", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 24.4, "final_year_of_manufacture": null, "raw": ["016871", "000208", "0", "2012/Jun/28 11:10", "Biasi UK", "Biasi", "Inovia", "25S", "41-583-26", "2012", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24.4", "24.4", "", "", "88.1", "79.1", "", "57.7", "", "2", "", "", "102", "1", "2", "102", "8.6", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "97.0", "", "", "", "", "95.3"]} -{"pcdb_id": 16872, "brand_name": "Biasi", "model_name": "Inovia", "model_qualifier": "25S", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 24.4, "final_year_of_manufacture": null, "raw": ["016872", "000208", "0", "2012/May/22 12:04", "Biasi UK", "Biasi", "Inovia", "25S", "", "2012", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "24.4", "24.4", "", "", "89.1", "80.1", "", "58.5", "", "2", "1", "", "102", "1", "2", "102", "8.6", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.7", "99.2", "", "", "", "", "97.4"]} -{"pcdb_id": 16873, "brand_name": "Biasi", "model_name": "Inovia", "model_qualifier": "30C", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 86.8, "comparative_hot_water_efficiency_pct": 74.1, "output_kw_max": 24.4, "final_year_of_manufacture": null, "raw": ["016873", "000208", "0", "2012/Jun/28 11:10", "Biasi UK", "Biasi", "Inovia", "30C", "47-583-33", "2012", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.4", "24.4", "", "", "88.0", "86.8", "", "74.1", "", "2", "", "", "104", "1", "2", "130", "8.6", "0", "", "", "", "0", "", "", "", "", "1", "7.104", "0.163", "0.002", "0.98571", "", "", "", "", "", "1", "1", "", "0005", "", "", "", "", "", "", "", "", "88.3", "96.7", "", "", "", "", "95.1"]} -{"pcdb_id": 16874, "brand_name": "Biasi", "model_name": "Inovia", "model_qualifier": "30C", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.4, "comparative_hot_water_efficiency_pct": 62.8, "output_kw_max": 24.4, "final_year_of_manufacture": null, "raw": ["016874", "000208", "0", "2013/Apr/08 10:20", "Biasi UK", "Biasi", "Inovia", "30C", "", "2012", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24.4", "24.4", "", "", "89.0", "80.4", "", "62.8", "", "2", "1", "", "104", "1", "2", "130", "8.6", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "", "0005", "", "", "", "", "", "", "", "", "90.3", "98.8", "", "", "", "", "97.2"]} -{"pcdb_id": 16875, "brand_name": "Biasi", "model_name": "Inovia", "model_qualifier": "35C", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 86.8, "comparative_hot_water_efficiency_pct": 74.0, "output_kw_max": 29.5, "final_year_of_manufacture": null, "raw": ["016875", "000208", "0", "2012/Jun/28 11:10", "Biasi UK", "Biasi", "Inovia", "35C", "47-583-34", "2012", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "29.5", "29.5", "", "", "88.0", "86.8", "", "74.0", "", "2", "", "", "104", "1", "2", "135", "8.6", "0", "", "", "", "0", "", "", "", "", "1", "7.12", "0.152", "0.002", "1.00577", "", "", "", "", "", "1", "1", "", "0005", "", "", "", "", "", "", "", "", "88.5", "96.7", "", "", "", "", "95.1"]} -{"pcdb_id": 16876, "brand_name": "Biasi", "model_name": "Inovia", "model_qualifier": "35C", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.4, "comparative_hot_water_efficiency_pct": 62.8, "output_kw_max": 29.5, "final_year_of_manufacture": null, "raw": ["016876", "000208", "0", "2013/Apr/08 10:21", "Biasi UK", "Biasi", "Inovia", "35C", "", "2012", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "29.5", "29.5", "", "", "89.0", "80.4", "", "62.8", "", "2", "1", "", "104", "1", "2", "135", "8.6", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "", "0005", "", "", "", "", "", "", "", "", "90.4", "98.8", "", "", "", "", "97.2"]} -{"pcdb_id": 16877, "brand_name": "Potterton", "model_name": "Titanium", "model_qualifier": "24", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 56.1, "output_kw_max": 20.0, "final_year_of_manufacture": 2015, "raw": ["016877", "000005", "0", "2015/Aug/06 13:08", "Baxi Heating UK", "Potterton", "Titanium", "24", "GC 47-393-39", "2012", "2015", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "20", "20", "", "", "88.4", "79.8", "", "56.1", "", "2", "", "", "104", "1", "2", "155", "5", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "90.0", "96.9", "", "", "", "", "95.6"]} -{"pcdb_id": 16878, "brand_name": "Potterton", "model_name": "Titanium", "model_qualifier": "28", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 56.1, "output_kw_max": 24.0, "final_year_of_manufacture": 2015, "raw": ["016878", "000005", "0", "2015/Aug/06 13:08", "Baxi Heating UK", "Potterton", "Titanium", "28", "GC No 47-393-40", "2012", "2015", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "88.4", "79.8", "", "56.1", "", "2", "", "", "104", "1", "2", "155", "5", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "90.0", "96.9", "", "", "", "", "95.6"]} -{"pcdb_id": 16879, "brand_name": "Potterton", "model_name": "Titanium", "model_qualifier": "33", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 56.0, "output_kw_max": 28.0, "final_year_of_manufacture": 2015, "raw": ["016879", "000005", "0", "2015/Aug/06 13:09", "Baxi Heating UK", "Potterton", "Titanium", "33", "GC No 47-393-41", "2012", "2015", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28", "28", "", "", "88.3", "79.7", "", "56.0", "", "2", "", "", "104", "1", "2", "160", "5", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "90.0", "96.7", "", "", "", "", "95.4"]} -{"pcdb_id": 16880, "brand_name": "Potterton", "model_name": "Titanium", "model_qualifier": "40", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 56.0, "output_kw_max": 32.0, "final_year_of_manufacture": 2015, "raw": ["016880", "000005", "0", "2015/Aug/06 13:09", "Baxi Heating UK", "Potterton", "Titanium", "40", "GC No 47-393-42", "2012", "2015", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "32", "32", "", "", "88.3", "79.7", "", "56.0", "", "2", "", "", "104", "1", "2", "160", "5", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "90.0", "96.7", "", "", "", "", "95.4"]} -{"pcdb_id": 16881, "brand_name": "British Gas", "model_name": "539/i", "model_qualifier": "", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 63.1, "output_kw_max": 30.0, "final_year_of_manufacture": null, "raw": ["016881", "000035", "0", "2012/May/22 15:44", "Bosch Thermotechnology", "British Gas", "539/i", "", "47-406-43", "2012", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "30", "30", "", "", "89.4", "80.8", "", "63.1", "", "2", "1", "", "104", "1", "2", "52", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "", "0005", "", "", "", "", "", "", "", "", "90.1", "99.9", "", "", "", "", "98.1"]} -{"pcdb_id": 16882, "brand_name": "British Gas", "model_name": "539/i", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 62.3, "output_kw_max": 30.0, "final_year_of_manufacture": null, "raw": ["016882", "000035", "0", "2012/May/22 15:45", "Bosch Thermotechnology", "British Gas", "539/i", "", "47-406-42", "2012", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "30.0", "30.0", "", "", "88.4", "79.8", "", "62.3", "", "2", "", "", "104", "1", "2", "52", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "", "0005", "", "", "", "", "", "", "", "", "88.1", "97.8", "", "", "", "", "95.9"]} -{"pcdb_id": 16883, "brand_name": "British Gas", "model_name": "535/i", "model_qualifier": "", "winter_efficiency_pct": 89.5, "summer_efficiency_pct": 80.9, "comparative_hot_water_efficiency_pct": 63.2, "output_kw_max": 30.0, "final_year_of_manufacture": null, "raw": ["016883", "000035", "0", "2012/May/22 15:46", "Bosch Thermotechnology", "British Gas", "535/i", "", "47-406-41", "2012", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "30.0", "30.0", "", "", "89.5", "80.9", "", "63.2", "", "2", "1", "", "104", "1", "2", "58", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "", "0005", "", "", "", "", "", "", "", "", "90.0", "100.2", "", "", "", "", "98.3"]} -{"pcdb_id": 16884, "brand_name": "British Gas", "model_name": "535/i", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 62.4, "output_kw_max": 30.0, "final_year_of_manufacture": null, "raw": ["016884", "000035", "0", "2012/May/22 15:47", "Bosch Thermotechnology", "British Gas", "535/i", "", "47-406-40", "2012", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "30", "30", "", "", "88.5", "79.9", "", "62.4", "", "2", "", "", "104", "1", "2", "58", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "", "0005", "", "", "", "", "", "", "", "", "88.0", "98.0", "", "", "", "", "96.1"]} -{"pcdb_id": 16885, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "38CDi Combi", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 63.1, "output_kw_max": 30.0, "final_year_of_manufacture": 2014, "raw": ["016885", "000035", "0", "2020/Sep/08 10:26", "Bosch Thermotechnology", "Worcester", "Greenstar", "38CDi Combi", "", "2012", "2014", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "30", "30", "", "", "89.4", "80.8", "", "63.1", "", "2", "1", "", "104", "1", "2", "52", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "", "0305", "", "", "", "", "", "", "", "", "90.1", "99.9", "", "", "", "", "98.1"]} -{"pcdb_id": 16886, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "38CDi Combi", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 62.3, "output_kw_max": 30.0, "final_year_of_manufacture": 2014, "raw": ["016886", "000035", "0", "2020/Sep/08 10:26", "Bosch Thermotechnology", "Worcester", "Greenstar", "38CDi Combi", "", "2012", "2014", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "30.0", "30.0", "", "", "88.4", "79.8", "", "62.3", "", "2", "", "", "104", "1", "2", "52", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "", "0305", "", "", "", "", "", "", "", "", "88.1", "97.8", "", "", "", "", "95.9"]} -{"pcdb_id": 16887, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "34 CDi Combi", "winter_efficiency_pct": 89.5, "summer_efficiency_pct": 80.9, "comparative_hot_water_efficiency_pct": 63.2, "output_kw_max": 30.0, "final_year_of_manufacture": 2014, "raw": ["016887", "000035", "0", "2020/Sep/08 10:26", "Bosch Thermotechnology", "Worcester", "Greenstar", "34 CDi Combi", "", "2012", "2014", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "30.0", "30.0", "", "", "89.5", "80.9", "", "63.2", "", "2", "1", "", "104", "1", "2", "58", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "", "0305", "", "", "", "", "", "", "", "", "90.0", "100.2", "", "", "", "", "98.3"]} -{"pcdb_id": 16888, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "34CDi Combi", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 62.4, "output_kw_max": 30.0, "final_year_of_manufacture": 2014, "raw": ["016888", "000035", "0", "2020/Sep/08 10:26", "Bosch Thermotechnology", "Worcester", "Greenstar", "34CDi Combi", "", "2012", "2014", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "30", "30", "", "", "88.5", "79.9", "", "62.4", "", "2", "", "", "104", "1", "2", "58", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "", "0305", "", "", "", "", "", "", "", "", "88.0", "98.0", "", "", "", "", "96.1"]} -{"pcdb_id": 16889, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "29CDi Combi", "winter_efficiency_pct": 89.5, "summer_efficiency_pct": 80.9, "comparative_hot_water_efficiency_pct": 63.2, "output_kw_max": 30.0, "final_year_of_manufacture": 2014, "raw": ["016889", "000035", "0", "2020/Sep/08 10:26", "Bosch Thermotechnology", "Worcester", "Greenstar", "29CDi Combi", "", "2012", "2014", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "30", "30", "", "", "89.5", "80.9", "", "63.2", "", "2", "1", "", "104", "1", "2", "58", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "", "0305", "", "", "", "", "", "", "", "", "90.0", "100.2", "", "", "", "", "98.3"]} -{"pcdb_id": 16890, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "29CDi Combi", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 62.4, "output_kw_max": 30.0, "final_year_of_manufacture": 2014, "raw": ["016890", "000035", "0", "2020/Sep/08 10:35", "Bosch Thermotechnology", "Worcester", "Greenstar", "29CDi Combi", "", "2012", "2014", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "30", "30", "", "", "88.5", "79.9", "", "62.4", "", "2", "", "", "104", "1", "2", "58", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "", "0305", "", "", "", "", "", "", "", "", "88.0", "98.0", "", "", "", "", "96.1"]} -{"pcdb_id": 16891, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "24", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 86.6, "comparative_hot_water_efficiency_pct": 69.7, "output_kw_max": 20.3, "final_year_of_manufacture": 2015, "raw": ["016891", "000035", "0", "2020/Sep/08 10:36", "Worcester Bosch Group", "Worcester", "Greenstar", "24", "47-406-32", "2012", "2015", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "20.3", "20.3", "", "", "88.0", "86.6", "", "69.7", "", "2", "", "", "104", "1", "2", "125", "9", "0", "", "", "", "0", "", "", "", "", "1", "7.558", "0.113", "0.0065", "1.38186", "", "", "", "", "", "", "", "", "0305", "", "", "", "", "", "", "", "", "87.8", "96.9", "", "", "", "", "95.1"]} -{"pcdb_id": 16892, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "28", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 86.6, "comparative_hot_water_efficiency_pct": 59.1, "output_kw_max": 20.3, "final_year_of_manufacture": 2015, "raw": ["016892", "000035", "0", "2020/Sep/08 10:36", "Worcester Bosch Group", "Worcester", "Greenstar", "28", "47-406-33", "2012", "2015", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "20.3", "20.3", "", "", "88.0", "86.6", "", "59.1", "", "2", "", "", "104", "1", "2", "125", "9", "0", "", "", "", "0", "", "", "", "", "1", "8.913", "0.199", "0.0296", "2.54937", "", "", "", "", "", "", "", "", "0305", "", "", "", "", "", "", "", "", "87.8", "96.9", "", "", "", "", "95.1"]} -{"pcdb_id": 16893, "brand_name": "Worcester", "model_name": "GB162-65kW", "model_qualifier": "", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 65.0, "final_year_of_manufacture": 2016, "raw": ["016893", "000035", "0", "2020/Sep/08 10:36", "Bosch Thermotechnology", "Worcester", "GB162-65kW", "", "", "2008", "2016", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "65", "65", "", "", "88.2", "79.2", "", "57.8", "", "2", "", "", "102", "1", "2", "99", "21", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "97.1", "", "", "", "", "95.5"]} -{"pcdb_id": 16894, "brand_name": "Heatline", "model_name": "Monza", "model_qualifier": "24a", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 62.2, "output_kw_max": 17.6, "final_year_of_manufacture": null, "raw": ["016894", "000215", "0", "2012/Jun/26 14:26", "Heatline", "Heatline", "Monza", "24a", "GC 47-157-25", "2012", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "17.6", "17.6", "", "", "88.3", "79.7", "", "62.2", "", "2", "", "", "104", "1", "2", "130", "10", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "", "0005", "", "", "", "", "", "", "", "", "87.8", "97.6", "", "", "", "", "95.7"]} -{"pcdb_id": 16895, "brand_name": "Heatline", "model_name": "Monza", "model_qualifier": "28a", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 61.9, "output_kw_max": 23.2, "final_year_of_manufacture": null, "raw": ["016895", "000215", "0", "2012/Jun/26 14:26", "Heatline", "Heatline", "Monza", "28a", "GC 47-157-26", "2012", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "23.2", "23.2", "", "", "87.9", "79.3", "", "61.9", "", "2", "", "", "104", "1", "2", "130", "10", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "", "0005", "", "", "", "", "", "", "", "", "87.2", "96.9", "", "", "", "", "95.1"]} -{"pcdb_id": 16896, "brand_name": "Heatline", "model_name": "CaprizPlus", "model_qualifier": "24a", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 62.2, "output_kw_max": 17.6, "final_year_of_manufacture": null, "raw": ["016896", "000215", "0", "2012/Jun/26 14:26", "Heatline", "Heatline", "CaprizPlus", "24a", "GC 47-157-23", "2012", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "17.6", "17.6", "", "", "88.3", "79.7", "", "62.2", "", "2", "", "", "104", "1", "2", "130", "10", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "", "0005", "", "", "", "", "", "", "", "", "87.8", "97.6", "", "", "", "", "95.7"]} -{"pcdb_id": 16897, "brand_name": "Heatline", "model_name": "CaprizPlus", "model_qualifier": "28a", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 61.9, "output_kw_max": 23.2, "final_year_of_manufacture": null, "raw": ["016897", "000215", "0", "2012/Jun/26 14:26", "Heatline", "Heatline", "CaprizPlus", "28a", "GC 47-157-24", "2012", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "23.2", "23.2", "", "", "87.9", "79.3", "", "61.9", "", "2", "", "", "104", "1", "2", "130", "10", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "", "0005", "", "", "", "", "", "", "", "", "87.2", "96.9", "", "", "", "", "95.1"]} -{"pcdb_id": 16899, "brand_name": "Morco", "model_name": "Morco 24 CPM", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 86.7, "comparative_hot_water_efficiency_pct": 71.8, "output_kw_max": 22.2, "final_year_of_manufacture": null, "raw": ["016899", "000248", "0", "2012/Jul/05 08:34", "Emas Makina Sanayi", "Morco", "Morco 24 CPM", "", "", "2012", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "22.2", "22.2", "", "", "88.1", "86.7", "", "71.8", "", "2", "", "", "104", "1", "2", "127", "5", "0", "", "", "0", "0", "", "", "", "", "1", "7.3381", "0.2007", "0.0144", "1.1294", "", "", "", "", "", "1", "1", "", "0005", "", "", "", "", "", "", "", "", "87.9", "97.0", "", "", "", "", "95.3"]} -{"pcdb_id": 16900, "brand_name": "Morco", "model_name": "Morco 24 CPM", "model_qualifier": "", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 62.8, "output_kw_max": 22.2, "final_year_of_manufacture": null, "raw": ["016900", "000248", "0", "2013/Apr/08 10:24", "Emas Makina Sanayi", "Morco", "Morco 24 CPM", "", "", "2012", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "22.2", "22.2", "", "", "89.1", "80.5", "", "62.8", "", "2", "1", "", "104", "1", "2", "127", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "", "0005", "", "", "", "", "", "", "", "", "89.9", "99.2", "", "", "", "", "97.4"]} -{"pcdb_id": 16901, "brand_name": "Morco", "model_name": "Morco 30 CPM", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 86.7, "comparative_hot_water_efficiency_pct": 70.5, "output_kw_max": 27.3, "final_year_of_manufacture": null, "raw": ["016901", "000248", "0", "2012/Jul/05 08:34", "Emas Makina Sanayi", "Morco", "Morco 30 CPM", "", "", "2012", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "27.3", "27.3", "", "", "88.1", "86.7", "", "70.5", "", "2", "", "", "104", "1", "2", "134", "5", "0", "", "", "0", "0", "", "", "", "", "1", "7.4688", "0.225", "0.008", "1.29467", "", "", "", "", "", "1", "1", "", "0005", "", "", "", "", "", "", "", "", "88.0", "97.0", "", "", "", "", "95.3"]} -{"pcdb_id": 16902, "brand_name": "Morco", "model_name": "Morco 30 CPM", "model_qualifier": "", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.4, "comparative_hot_water_efficiency_pct": 62.8, "output_kw_max": 27.3, "final_year_of_manufacture": null, "raw": ["016902", "000248", "0", "2013/Apr/08 10:24", "Emas Makina Sanayi", "Morco", "Morco 30 CPM", "", "", "2012", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "27.3", "27.3", "", "", "89.0", "80.4", "", "62.8", "", "2", "1", "", "104", "1", "2", "134", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "", "0005", "", "", "", "", "", "", "", "", "90.0", "99.0", "", "", "", "", "97.3"]} -{"pcdb_id": 16903, "brand_name": "Alpha", "model_name": "Eco", "model_qualifier": "", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 86.8, "comparative_hot_water_efficiency_pct": 79.6, "output_kw_max": 23.7, "final_year_of_manufacture": 2015, "raw": ["016903", "000001", "0", "2012/Jun/27 13:03", "Alpha Therm", "Alpha", "Eco", "", "", "2012", "2015", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "23.7", "23.7", "", "", "88.2", "86.8", "", "79.6", "", "2", "", "", "104", "1", "2", "115", "6.4", "0", "", "", "", "0", "", "", "", "", "1", "6.618", "0.18", "0.005", "0.50223", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.4", "97.0", "", "", "", "", "95.4"]} -{"pcdb_id": 16904, "brand_name": "Sime", "model_name": "Brava DGT HE", "model_qualifier": "25", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 56.2, "output_kw_max": 23.9, "final_year_of_manufacture": 2018, "raw": ["016904", "000213", "0", "2018/Feb/26 16:31", "Fonderie Sime S.p.A.", "Sime", "Brava DGT HE", "25", "", "2012", "2018", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "23.9", "23.9", "", "", "88.5", "79.9", "", "56.2", "", "2", "", "", "104", "1", "2", "105", "4.9", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.6", "97.9", "", "", "", "", "96.2"]} -{"pcdb_id": 16905, "brand_name": "Sime", "model_name": "Brava DGT HE", "model_qualifier": "25", "winter_efficiency_pct": 89.6, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 56.9, "output_kw_max": 23.9, "final_year_of_manufacture": 2018, "raw": ["016905", "000213", "0", "2018/Feb/26 16:32", "Fonderie Sime S.p.A.", "Sime", "Brava DGT HE", "25", "", "2012", "2018", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "23.9", "23.9", "", "", "89.6", "81.0", "", "56.9", "", "2", "1", "", "104", "1", "2", "105", "4.9", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.5", "100.1", "", "", "", "", "98.3"]} -{"pcdb_id": 16906, "brand_name": "Sime", "model_name": "Brava DGT HE", "model_qualifier": "30", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 56.0, "output_kw_max": 28.9, "final_year_of_manufacture": 2018, "raw": ["016906", "000213", "0", "2018/Feb/26 16:33", "Fonderie Sime S.p.A.", "Sime", "Brava DGT HE", "30", "", "2012", "2018", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28.9", "28.9", "", "", "88.3", "79.7", "", "56.0", "", "2", "", "", "104", "1", "2", "115", "4.9", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "97.4", "", "", "", "", "95.7"]} -{"pcdb_id": 16907, "brand_name": "Sime", "model_name": "Brava DGT HE", "model_qualifier": "30", "winter_efficiency_pct": 89.3, "summer_efficiency_pct": 80.7, "comparative_hot_water_efficiency_pct": 56.7, "output_kw_max": 28.9, "final_year_of_manufacture": 2018, "raw": ["016907", "000213", "0", "2018/Feb/26 16:34", "Fonderie Sime S.p.A.", "Sime", "Brava DGT HE", "30", "", "2012", "2018", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "28.9", "28.9", "", "", "89.3", "80.7", "", "56.7", "", "2", "1", "", "104", "1", "2", "115", "4.9", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.3", "99.6", "", "", "", "", "97.8"]} -{"pcdb_id": 16908, "brand_name": "Ariston", "model_name": "E-Combi evo 24", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 86.6, "comparative_hot_water_efficiency_pct": 70.5, "output_kw_max": 21.5, "final_year_of_manufacture": null, "raw": ["016908", "000080", "0", "2013/Jan/30 09:37", "Ariston Thermo UK", "Ariston", "E-Combi evo 24", "", "", "2012", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "21.5", "21.5", "", "", "88.1", "86.6", "", "70.5", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "", "0", "", "", "", "", "1", "7.472", "0.129", "0.0083", "1.29141", "", "", "", "", "", "1", "0", "", "0805", "", "", "", "", "", "", "", "", "87.8", "97.0", "", "", "", "", "95.3"]} -{"pcdb_id": 16909, "brand_name": "Ariston", "model_name": "E-Combi evo 30", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 86.7, "comparative_hot_water_efficiency_pct": 70.8, "output_kw_max": 27.3, "final_year_of_manufacture": null, "raw": ["016909", "000080", "0", "2013/Jan/30 09:36", "Ariston Thermo UK", "Ariston", "E-Combi evo 30", "", "", "2012", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "27.3", "27.3", "", "", "88.1", "86.7", "", "70.8", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "", "0", "", "", "", "", "1", "7.441", "0.136", "0.0076", "1.26812", "", "", "", "", "", "1", "0", "", "0805", "", "", "", "", "", "", "", "", "87.9", "97.0", "", "", "", "", "95.3"]} -{"pcdb_id": 16910, "brand_name": "Ariston", "model_name": "E-Combi evo 38", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 86.7, "comparative_hot_water_efficiency_pct": 69.4, "output_kw_max": 30.2, "final_year_of_manufacture": null, "raw": ["016910", "000080", "0", "2013/Jan/30 09:35", "Ariston Thermo UK", "Ariston", "E-Combi evo 38", "", "", "2012", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "30.2", "30.2", "", "", "88.1", "86.7", "", "69.4", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "", "0", "", "", "", "", "1", "7.59", "0.13", "0.0056", "1.42284", "", "", "", "", "", "1", "0", "", "0805", "", "", "", "", "", "", "", "", "87.9", "97.0", "", "", "", "", "95.3"]} -{"pcdb_id": 16911, "brand_name": "Ariston", "model_name": "Clas HE evo 24", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 86.6, "comparative_hot_water_efficiency_pct": 70.5, "output_kw_max": 21.5, "final_year_of_manufacture": null, "raw": ["016911", "000080", "0", "2013/Jan/30 09:30", "Ariston Thermo UK", "Ariston", "Clas HE evo 24", "", "", "2012", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "21.5", "21.5", "", "", "88.1", "86.6", "", "70.5", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "", "0", "", "", "", "", "1", "7.472", "0.129", "0.0083", "1.29141", "", "", "", "", "", "1", "0", "", "0805", "", "", "", "", "", "", "", "", "87.8", "97.0", "", "", "", "", "95.3"]} -{"pcdb_id": 16912, "brand_name": "Ariston", "model_name": "Clas HE evo 30", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 86.7, "comparative_hot_water_efficiency_pct": 70.8, "output_kw_max": 27.3, "final_year_of_manufacture": null, "raw": ["016912", "000080", "0", "2013/Jan/30 09:30", "Ariston Thermo UK", "Ariston", "Clas HE evo 30", "", "", "2012", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "27.3", "27.3", "", "", "88.1", "86.7", "", "70.8", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "", "0", "", "", "", "", "1", "7.441", "0.136", "0.0076", "1.26812", "", "", "", "", "", "1", "0", "", "0805", "", "", "", "", "", "", "", "", "87.9", "97.0", "", "", "", "", "95.3"]} -{"pcdb_id": 16913, "brand_name": "Ariston", "model_name": "Clas HE evo 38", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 86.7, "comparative_hot_water_efficiency_pct": 69.4, "output_kw_max": 30.2, "final_year_of_manufacture": null, "raw": ["016913", "000080", "0", "2013/Jan/30 09:33", "Ariston Thermo UK", "Ariston", "Clas HE evo 38", "", "", "2012", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "30.2", "30.2", "", "", "88.1", "86.7", "", "69.4", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "", "0", "", "", "", "", "1", "7.59", "0.13", "0.0056", "1.42284", "", "", "", "", "", "1", "0", "", "0805", "", "", "", "", "", "", "", "", "87.9", "97.0", "", "", "", "", "95.3"]} -{"pcdb_id": 16914, "brand_name": "Ariston", "model_name": "E-System evo 24", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 21.6, "final_year_of_manufacture": null, "raw": ["016914", "000080", "0", "2013/Jan/28 14:57", "Ariston Thermo UK", "Ariston", "E-System evo 24", "", "", "2012", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "21.6", "21.6", "", "", "88.1", "79.1", "", "57.8", "", "2", "", "", "102", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0805", "", "", "", "", "", "", "", "", "87.8", "97.0", "", "", "", "", "95.3"]} -{"pcdb_id": 16915, "brand_name": "Ariston", "model_name": "E-System evo 30", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 27.3, "final_year_of_manufacture": null, "raw": ["016915", "000080", "0", "2013/Jan/28 14:57", "Ariston Thermo UK", "Ariston", "E-System evo 30", "", "", "2012", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "27.3", "27.3", "", "", "88.1", "79.1", "", "57.8", "", "2", "", "", "102", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0805", "", "", "", "", "", "", "", "", "87.9", "97.0", "", "", "", "", "95.3"]} -{"pcdb_id": 16916, "brand_name": "Ariston", "model_name": "Clas HE System evo 18", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 17.6, "final_year_of_manufacture": null, "raw": ["016916", "000080", "0", "2013/Jan/28 14:57", "Ariston Thermo UK", "Ariston", "Clas HE System evo 18", "", "", "2012", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "17.6", "17.6", "", "", "88.1", "79.1", "", "57.8", "", "2", "", "", "102", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0805", "", "", "", "", "", "", "", "", "87.9", "97.0", "", "", "", "", "95.3"]} -{"pcdb_id": 16917, "brand_name": "Ariston", "model_name": "Clas HE System evo 24", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 21.5, "final_year_of_manufacture": null, "raw": ["016917", "000080", "0", "2013/Jan/28 14:58", "Ariston Thermo UK", "Ariston", "Clas HE System evo 24", "", "", "2012", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "21.5", "21.5", "", "", "88.1", "79.1", "", "57.8", "", "2", "", "", "102", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0805", "", "", "", "", "", "", "", "", "87.8", "97.0", "", "", "", "", "95.3"]} -{"pcdb_id": 16918, "brand_name": "Ariston", "model_name": "Clas HE System evo 30", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 27.3, "final_year_of_manufacture": null, "raw": ["016918", "000080", "0", "2013/Jan/28 14:58", "Ariston Thermo UK", "Ariston", "Clas HE System evo 30", "", "", "2012", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "27.3", "27.3", "", "", "88.1", "79.1", "", "57.8", "", "2", "", "", "102", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0805", "", "", "", "", "", "", "", "", "87.9", "97.0", "", "", "", "", "95.3"]} -{"pcdb_id": 16919, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "29CDi Classic", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 86.7, "comparative_hot_water_efficiency_pct": 71.2, "output_kw_max": 30.0, "final_year_of_manufacture": 2015, "raw": ["016919", "000035", "0", "2020/Sep/08 10:36", "Bosch Thermotechnology", "Worcester", "Greenstar", "29CDi Classic", "", "2012", "2015", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "30", "30", "", "", "88.5", "86.7", "", "71.2", "", "2", "", "", "104", "1", "2", "58", "2", "0", "", "", "", "0", "", "", "", "", "1", "7.4", "0.122", "0.0061", "1.23987", "", "", "", "", "", "1", "1", "", "0305", "", "", "", "", "", "", "", "", "88.0", "98.0", "", "", "", "", "96.1"]} -{"pcdb_id": 16921, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "34CDi Classic", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 86.7, "comparative_hot_water_efficiency_pct": 72.3, "output_kw_max": 30.0, "final_year_of_manufacture": 2015, "raw": ["016921", "000035", "0", "2020/Sep/08 10:36", "Bosch Thermotechnology", "Worcester", "Greenstar", "34CDi Classic", "", "2012", "2015", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "30", "30", "", "", "88.5", "86.7", "", "72.3", "", "2", "", "", "104", "1", "2", "58", "2", "0", "", "", "", "0", "", "", "", "", "1", "7.28", "0.123", "0.0039", "1.13727", "", "", "", "", "", "1", "1", "", "0305", "", "", "", "", "", "", "", "", "88.0", "98.0", "", "", "", "", "96.1"]} -{"pcdb_id": 16922, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "38CDi Classic", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 86.7, "comparative_hot_water_efficiency_pct": 71.5, "output_kw_max": 30.0, "final_year_of_manufacture": 2015, "raw": ["016922", "000035", "0", "2020/Sep/08 10:36", "Bosch Thermotechnology", "Worcester", "Greenstar", "38CDi Classic", "", "2012", "2015", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "30", "30", "", "", "88.4", "86.7", "", "71.5", "", "2", "", "", "104", "1", "2", "52", "2", "0", "", "0", "", "0", "", "", "", "", "1", "7.37", "0.129", "0.0039", "1.22598", "", "", "", "", "", "1", "1", "", "0305", "", "", "", "", "", "", "", "", "88.1", "97.8", "", "", "", "", "95.9"]} -{"pcdb_id": 16923, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "42CDi Classic", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 86.7, "comparative_hot_water_efficiency_pct": 72.0, "output_kw_max": 30.0, "final_year_of_manufacture": 2015, "raw": ["016923", "000035", "0", "2020/Sep/08 10:37", "Bosch Thermotechnology", "Worcester", "Greenstar", "42CDi Classic", "", "2012", "2015", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "30.0", "30.0", "", "", "88.8", "86.7", "", "72.0", "", "2", "", "", "104", "1", "2", "51", "2", "0", "", "", "", "0", "", "", "", "", "1", "7.31", "0.128", "0.0049", "1.16268", "", "", "", "", "", "1", "1", "", "0305", "", "", "", "", "", "", "", "", "88.1", "98.8", "", "", "", "", "96.8"]} -{"pcdb_id": 16924, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "29CDi Classic", "winter_efficiency_pct": 89.5, "summer_efficiency_pct": 80.9, "comparative_hot_water_efficiency_pct": 63.2, "output_kw_max": 30.0, "final_year_of_manufacture": 2015, "raw": ["016924", "000035", "0", "2020/Sep/08 10:37", "Bosch Thermotechnology", "Worcester", "Greenstar", "29CDi Classic", "", "2012", "2015", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "30", "30", "", "", "89.5", "80.9", "", "63.2", "", "2", "1", "", "104", "1", "2", "58", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "", "0305", "", "", "", "", "", "", "", "", "90.0", "100.2", "", "", "", "", "98.3"]} -{"pcdb_id": 16925, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "34CDi Classic", "winter_efficiency_pct": 89.5, "summer_efficiency_pct": 80.9, "comparative_hot_water_efficiency_pct": 63.2, "output_kw_max": 30.0, "final_year_of_manufacture": 2015, "raw": ["016925", "000035", "0", "2020/Sep/08 10:37", "Bosch Thermotechnology", "Worcester", "Greenstar", "34CDi Classic", "", "2012", "2015", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "30.0", "30.0", "", "", "89.5", "80.9", "", "63.2", "", "2", "1", "", "104", "1", "2", "58", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "", "0305", "", "", "", "", "", "", "", "", "90.0", "100.2", "", "", "", "", "98.3"]} -{"pcdb_id": 16926, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "38CDi Classic", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 63.1, "output_kw_max": 30.0, "final_year_of_manufacture": 2015, "raw": ["016926", "000035", "0", "2020/Sep/08 10:37", "Bosch Thermotechnology", "Worcester", "Greenstar", "38CDi Classic", "", "2012", "2015", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "30.0", "30.0", "", "", "89.4", "80.8", "", "63.1", "", "2", "1", "", "104", "1", "2", "52", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "", "0305", "", "", "", "", "", "", "", "", "90.1", "99.9", "", "", "", "", "98.1"]} -{"pcdb_id": 16927, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "42CDi Classic", "winter_efficiency_pct": 89.8, "summer_efficiency_pct": 81.2, "comparative_hot_water_efficiency_pct": 63.4, "output_kw_max": 30.0, "final_year_of_manufacture": 2015, "raw": ["016927", "000035", "0", "2020/Sep/08 10:37", "Bosch Thermotechnology", "Worcester", "Greenstar", "42CDi Classic", "", "2012", "2015", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "30.0", "30.0", "", "", "89.8", "81.2", "", "63.4", "", "2", "1", "", "104", "1", "2", "51", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "", "0305", "", "", "", "", "", "", "", "", "90.1", "101.0", "", "", "", "", "99.0"]} -{"pcdb_id": 16928, "brand_name": "Main", "model_name": "System Eco Elite", "model_qualifier": "24", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 25.94, "final_year_of_manufacture": 2015, "raw": ["016928", "000005", "0", "2015/Aug/06 13:13", "Baxi Heating UK", "Main", "System Eco Elite", "24", "GC No 41-467-21", "2012", "2015", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "25.94", "25.94", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "150", "3.5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.7", "97.0", "", "", "", "", "95.7"]} -{"pcdb_id": 16929, "brand_name": "Main", "model_name": "System Eco Elite", "model_qualifier": "28", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 28.63, "final_year_of_manufacture": 2015, "raw": ["016929", "000005", "0", "2015/Aug/06 13:14", "Baxi Heating UK", "Main", "System Eco Elite", "28", "GC No 41-467-22", "2012", "2015", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "28.63", "28.63", "", "", "88.1", "79.1", "", "57.8", "", "2", "", "", "102", "1", "2", "150", "3.5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "97.0", "", "", "", "", "95.3"]} -{"pcdb_id": 16930, "brand_name": "Main", "model_name": "Combi Eco Elite", "model_qualifier": "25", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 56.1, "output_kw_max": 25.0, "final_year_of_manufacture": 2015, "raw": ["016930", "000005", "0", "2015/Aug/06 13:14", "Baxi Heating UK", "Main", "Combi Eco Elite", "25", "GC No 47-467-08", "2012", "2015", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "25", "25", "", "", "88.4", "79.8", "", "56.1", "", "2", "", "", "104", "1", "2", "150", "3.5", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "89.7", "97.0", "", "", "", "", "95.7"]} -{"pcdb_id": 16931, "brand_name": "Main", "model_name": "Combi Eco Elite", "model_qualifier": "30", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 55.9, "output_kw_max": 30.0, "final_year_of_manufacture": 2015, "raw": ["016931", "000005", "0", "2015/Aug/06 13:15", "Baxi Heating UK", "Main", "Combi Eco Elite", "30", "GC No 47-467-09", "2012", "2015", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "30", "30", "", "", "88.1", "79.5", "", "55.9", "", "2", "", "", "104", "1", "2", "150", "3.5", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "88.0", "97.0", "", "", "", "", "95.3"]} -{"pcdb_id": 16932, "brand_name": "De Dietrich Thermique", "model_name": "EMC-M", "model_qualifier": "24", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 23.4, "final_year_of_manufacture": null, "raw": ["016932", "000272", "0", "2012/Nov/12 10:42", "Remeha B.V", "De Dietrich Thermique", "EMC-M", "24", "0063CM3019", "2012", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "1", "23.4", "23.4", "", "", "88.7", "79.7", "", "58.2", "", "2", "", "", "102", "1", "2", "117", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.4", "98.5", "", "", "", "", "96.6"]} -{"pcdb_id": 16933, "brand_name": "De Dietrich Thermique", "model_name": "EMC-M", "model_qualifier": "24/28MI", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 23.4, "final_year_of_manufacture": null, "raw": ["016933", "000272", "0", "2012/Nov/12 10:42", "Remeha B.V", "De Dietrich Thermique", "EMC-M", "24/28MI", "", "2012", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "23.4", "23.4", "", "", "88.6", "79.6", "", "58.2", "", "2", "", "", "102", "1", "2", "117", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "98.4", "", "", "", "", "96.4"]} -{"pcdb_id": 16934, "brand_name": "De Dietrich Thermique", "model_name": "EMC-M", "model_qualifier": "30/35MI", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 29.2, "final_year_of_manufacture": null, "raw": ["016934", "000272", "0", "2012/Nov/12 10:42", "Remeha B.V", "De Dietrich Thermique", "EMC-M", "30/35MI", "", "2012", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "29.2", "29.2", "", "", "88.5", "79.5", "", "58.1", "", "2", "", "", "102", "1", "2", "145", "30", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.6", "98.2", "", "", "", "", "96.2"]} -{"pcdb_id": 16935, "brand_name": "De Dietrich Thermique", "model_name": "EMC-M", "model_qualifier": "34/39MI", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 33.8, "final_year_of_manufacture": null, "raw": ["016935", "000272", "0", "2012/Nov/12 10:41", "Remeha B.V", "De Dietrich Thermique", "EMC-M", "34/39MI", "", "2012", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "33.8", "33.8", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "159", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.3", "98.0", "", "", "", "", "96.0"]} -{"pcdb_id": 16936, "brand_name": "De Dietrich Thermique", "model_name": "EMC-M", "model_qualifier": "24", "winter_efficiency_pct": 89.7, "summer_efficiency_pct": 80.7, "comparative_hot_water_efficiency_pct": 59.0, "output_kw_max": 23.4, "final_year_of_manufacture": null, "raw": ["016936", "000272", "0", "2012/Nov/12 10:41", "Remeha B.V", "De Dietrich Thermique", "EMC-M", "24", "", "2012", "current", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "23.4", "23.4", "", "", "89.7", "80.7", "", "59.0", "", "2", "1", "", "102", "1", "2", "117", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.4", "100.7", "", "", "", "", "98.7"]} -{"pcdb_id": 16937, "brand_name": "De Dietrich Thermique", "model_name": "EMC-M", "model_qualifier": "24/28MI", "winter_efficiency_pct": 89.6, "summer_efficiency_pct": 80.6, "comparative_hot_water_efficiency_pct": 58.9, "output_kw_max": 23.4, "final_year_of_manufacture": null, "raw": ["016937", "000272", "0", "2012/Nov/12 10:41", "Remeha B.V", "De Dietrich Thermique", "EMC-M", "24/28MI", "", "2012", "current", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "23.4", "23.4", "", "", "89.6", "80.6", "", "58.9", "", "2", "1", "", "102", "1", "2", "117", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.9", "100.6", "", "", "", "", "98.5"]} -{"pcdb_id": 16939, "brand_name": "De Dietrich Thermique", "model_name": "EMC-M", "model_qualifier": "30/35MI", "winter_efficiency_pct": 89.5, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 58.8, "output_kw_max": 29.2, "final_year_of_manufacture": null, "raw": ["016939", "000272", "0", "2012/Nov/12 10:41", "Remeha B.V", "De Dietrich Thermique", "EMC-M", "30/35MI", "", "2012", "current", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "29.2", "29.2", "", "", "89.5", "80.5", "", "58.8", "", "2", "1", "", "102", "1", "2", "145", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.5", "100.4", "", "", "", "", "98.3"]} -{"pcdb_id": 16940, "brand_name": "De Dietrich Thermique", "model_name": "EMC-M", "model_qualifier": "34/39MI", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 80.4, "comparative_hot_water_efficiency_pct": 58.7, "output_kw_max": 33.8, "final_year_of_manufacture": null, "raw": ["016940", "000272", "0", "2013/Feb/11 10:02", "Remeha B.V", "De Dietrich Thermique", "EMC-M", "34/39MI", "", "2012", "current", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "33.8", "33.8", "", "", "89.4", "80.4", "", "58.7", "", "2", "1", "", "102", "1", "2", "159", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.2", "100.2", "", "", "", "", "98.1"]} -{"pcdb_id": 16941, "brand_name": "Ferroli", "model_name": "Modena 18S HE", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 17.0, "final_year_of_manufacture": null, "raw": ["016941", "000097", "0", "2013/Mar/28 08:32", "Ferroli", "Ferroli", "Modena 18S HE", "", "", "2012", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "17", "17", "", "", "88.5", "79.5", "", "58.1", "", "2", "", "", "102", "1", "2", "90", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "98.0", "", "", "", "", "96.2"]} -{"pcdb_id": 16942, "brand_name": "Ferroli", "model_name": "Modena 25S HE", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 24.5, "final_year_of_manufacture": null, "raw": ["016942", "000097", "0", "2013/Mar/28 08:32", "Ferroli", "Ferroli", "Modena 25S HE", "", "", "2012", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24.5", "24.5", "", "", "88.6", "79.6", "", "58.1", "", "2", "", "", "102", "1", "2", "100", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.5", "98.0", "", "", "", "", "96.2"]} -{"pcdb_id": 16943, "brand_name": "Ferroli", "model_name": "Modena 25C HE", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 56.2, "output_kw_max": 24.5, "final_year_of_manufacture": 2012, "raw": ["016943", "000097", "0", "2016/Apr/04 12:50", "Ferroli", "Ferroli", "Modena 25C HE", "", "", "2011", "2012", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.5", "24.5", "", "", "88.5", "79.9", "", "56.2", "", "2", "", "", "104", "1", "2", "100", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "98.0", "", "", "", "", "96.2"]} -{"pcdb_id": 16944, "brand_name": "Ferroli", "model_name": "Modena 27C HE", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 86.8, "comparative_hot_water_efficiency_pct": 71.8, "output_kw_max": 24.5, "final_year_of_manufacture": null, "raw": ["016944", "000097", "0", "2016/Apr/11 08:57", "Ferroli", "Ferroli", "Modena 27C HE", "", "", "2012", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.5", "24.5", "", "", "88.6", "86.8", "", "71.8", "", "2", "", "", "104", "1", "2", "80", "3", "0", "", "", "", "0", "", "", "", "", "1", "7.3361", "0.07487", "0.0043", "1.20061", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.5", "98.0", "", "", "", "", "96.2"]} -{"pcdb_id": 16945, "brand_name": "Ferroli", "model_name": "Modena 30C HE", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 56.2, "output_kw_max": 28.9, "final_year_of_manufacture": 2012, "raw": ["016945", "000097", "0", "2012/Oct/15 08:36", "Ferroli", "Ferroli", "Modena 30C HE", "", "", "2011", "2012", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28.9", "28.9", "", "", "88.6", "80.0", "", "56.2", "", "2", "", "", "104", "1", "2", "120", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.4", "98.1", "", "", "", "", "96.3"]} -{"pcdb_id": 16946, "brand_name": "Ferroli", "model_name": "Modena 32C HE", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 86.8, "comparative_hot_water_efficiency_pct": 74.6, "output_kw_max": 28.9, "final_year_of_manufacture": null, "raw": ["016946", "000097", "0", "2016/Apr/11 08:58", "Ferroli", "Ferroli", "Modena 32C HE", "", "", "2012", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28.9", "28.9", "", "", "88.6", "86.8", "", "74.6", "", "2", "", "", "104", "1", "2", "95", "3", "0", "", "", "", "0", "", "", "", "", "1", "7.0622", "0.07685", "0.0004", "0.95699", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.4", "98.1", "", "", "", "", "96.3"]} -{"pcdb_id": 16947, "brand_name": "Fondital", "model_name": "Antea KC 28", "model_qualifier": "", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 56.3, "output_kw_max": 25.4, "final_year_of_manufacture": null, "raw": ["016947", "000250", "0", "2013/Apr/08 10:25", "Fondital", "Fondital", "Antea KC 28", "", "", "2011", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "25.4", "25.4", "", "", "88.7", "80.1", "", "56.3", "", "2", "1", "", "104", "1", "2", "133", "2.3", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.8", "98.5", "", "", "", "", "96.7"]} -{"pcdb_id": 16948, "brand_name": "Fondital", "model_name": "Antea KC 28", "model_qualifier": "", "winter_efficiency_pct": 87.7, "summer_efficiency_pct": 86.3, "comparative_hot_water_efficiency_pct": 75.0, "output_kw_max": 25.4, "final_year_of_manufacture": null, "raw": ["016948", "000250", "0", "2012/Nov/29 12:57", "Fondital", "Fondital", "Antea KC 28", "", "", "2011", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "25.4", "25.4", "", "", "87.7", "86.3", "", "75.0", "", "2", "", "", "104", "1", "2", "133", "2.3", "0", "", "", "", "0", "", "", "", "", "1", "7.02", "0.072", "0.0085", "0.83037", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "86.9", "96.4", "", "", "", "", "94.6"]} -{"pcdb_id": 16949, "brand_name": "Fondital", "model_name": "Antea KR 28", "model_qualifier": "", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 25.4, "final_year_of_manufacture": null, "raw": ["016949", "000250", "0", "2012/Nov/29 12:57", "Fondital", "Fondital", "Antea KR 28", "", "", "2011", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "25.4", "25.4", "", "", "88.7", "79.7", "", "58.2", "", "2", "1", "", "102", "1", "2", "133", "2.3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.8", "98.5", "", "", "", "", "96.7"]} -{"pcdb_id": 16950, "brand_name": "Fondital", "model_name": "Antea KR 28", "model_qualifier": "", "winter_efficiency_pct": 87.7, "summer_efficiency_pct": 78.7, "comparative_hot_water_efficiency_pct": 57.5, "output_kw_max": 25.4, "final_year_of_manufacture": null, "raw": ["016950", "000250", "0", "2012/Nov/29 12:58", "Fondital", "Fondital", "Antea KR 28", "", "", "2011", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "25.4", "25.4", "", "", "87.7", "78.7", "", "57.5", "", "2", "", "", "102", "1", "2", "133", "2.3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "86.9", "96.4", "", "", "", "", "94.6"]} -{"pcdb_id": 16951, "brand_name": "Fondital", "model_name": "Itaca KC 24", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 56.2, "output_kw_max": 22.9, "final_year_of_manufacture": null, "raw": ["016951", "000250", "0", "2012/Nov/29 12:58", "Fondital", "Fondital", "Itaca KC 24", "", "", "2012", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "22.9", "22.9", "", "", "88.5", "79.9", "", "56.2", "", "2", "1", "", "104", "1", "2", "121", "2.4", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.1", "98.1", "", "", "", "", "96.4"]} -{"pcdb_id": 16952, "brand_name": "Fondital", "model_name": "Itaca KC 24", "model_qualifier": "", "winter_efficiency_pct": 87.5, "summer_efficiency_pct": 88.2, "comparative_hot_water_efficiency_pct": 74.3, "output_kw_max": 22.9, "final_year_of_manufacture": null, "raw": ["016952", "000250", "0", "2020/Apr/09 16:27", "Fondital", "Fondital", "Itaca KC 24", "", "", "2012", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "22.9", "22.9", "", "", "87.5", "88.2", "", "74.3", "", "2", "", "", "104", "1", "2", "121", "2.4", "0", "", "", "", "0", "", "", "", "", "3", "7.09", "0.083", "0.0011", "", "3.42", "0.078", "0.0034", "0.95054", "0.00004", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.1", "96.0", "", "", "", "", "94.3"]} -{"pcdb_id": 16954, "brand_name": "Fondital", "model_name": "Itaca KC 28", "model_qualifier": "", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 62.5, "output_kw_max": 25.4, "final_year_of_manufacture": null, "raw": ["016954", "000250", "0", "2012/Nov/29 12:59", "Fondital", "Fondital", "Itaca KC 28", "", "", "2012", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "25.4", "25.4", "", "", "88.7", "80.1", "", "62.5", "", "2", "1", "", "104", "1", "2", "121", "2.4", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "", "0005", "", "", "", "", "", "", "", "", "88.8", "98.5", "", "", "", "", "96.7"]} -{"pcdb_id": 16955, "brand_name": "Fondital", "model_name": "Itaca KC 28", "model_qualifier": "", "winter_efficiency_pct": 87.7, "summer_efficiency_pct": 81.7, "comparative_hot_water_efficiency_pct": 59.4, "output_kw_max": 25.4, "final_year_of_manufacture": null, "raw": ["016955", "000250", "0", "2020/Apr/09 16:27", "Fondital", "Fondital", "Itaca KC 28", "", "", "2012", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "25.4", "25.4", "", "", "87.7", "81.7", "", "59.4", "", "2", "", "", "104", "1", "2", "121", "2.4", "0", "", "", "", "0", "", "", "", "", "3", "8.86", "0.171", "0.0236", "", "4.6", "0.165", "0.0092", "1.89165", "-0.00022", "1", "1", "", "0005", "", "", "", "", "", "", "", "", "86.9", "96.4", "", "", "", "", "94.6"]} -{"pcdb_id": 16956, "brand_name": "Fondital", "model_name": "Itaca KC 32", "model_qualifier": "", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 80.6, "comparative_hot_water_efficiency_pct": 62.9, "output_kw_max": 29.4, "final_year_of_manufacture": null, "raw": ["016956", "000250", "0", "2012/Nov/29 13:02", "Fondital", "Fondital", "Itaca KC 32", "", "", "2012", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "29.4", "29.4", "", "", "89.2", "80.6", "", "62.9", "", "2", "1", "", "104", "1", "2", "121", "2.4", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "", "0005", "", "", "", "", "", "", "", "", "89.2", "99.7", "", "", "", "", "97.7"]} -{"pcdb_id": 16957, "brand_name": "Fondital", "model_name": "Itaca KC 32", "model_qualifier": "", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 81.7, "comparative_hot_water_efficiency_pct": 59.4, "output_kw_max": 29.4, "final_year_of_manufacture": null, "raw": ["016957", "000250", "0", "2020/Apr/09 16:26", "Fondital", "Fondital", "Itaca KC 32", "", "", "2012", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "29.4", "29.4", "", "", "88.2", "81.7", "", "59.4", "", "2", "", "", "104", "1", "2", "121", "2.4", "0", "", "", "", "0", "", "", "", "", "3", "8.86", "0.171", "0.0236", "", "4.6", "0.165", "0.0092", "1.89165", "-0.00022", "1", "1", "", "0005", "", "", "", "", "", "", "", "", "87.2", "97.6", "", "", "", "", "95.6"]} -{"pcdb_id": 16958, "brand_name": "Fondital", "model_name": "Itaca KR 24", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 22.9, "final_year_of_manufacture": null, "raw": ["016958", "000250", "0", "2012/Nov/29 13:03", "Fondital", "Fondital", "Itaca KR 24", "", "", "2012", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "22.9", "22.9", "", "", "88.5", "79.5", "", "58.1", "", "2", "1", "", "102", "1", "2", "121", "2.4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.1", "98.1", "", "", "", "", "96.4"]} -{"pcdb_id": 16959, "brand_name": "Fondital", "model_name": "Itaca KR 24", "model_qualifier": "", "winter_efficiency_pct": 87.5, "summer_efficiency_pct": 78.5, "comparative_hot_water_efficiency_pct": 57.4, "output_kw_max": 22.9, "final_year_of_manufacture": null, "raw": ["016959", "000250", "0", "2012/Nov/29 13:03", "Fondital", "Fondital", "Itaca KR 24", "", "", "2012", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "22.9", "22.9", "", "", "87.5", "78.5", "", "57.4", "", "2", "", "", "102", "1", "2", "121", "2.4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.1", "96.0", "", "", "", "", "94.3"]} -{"pcdb_id": 16960, "brand_name": "Fondital", "model_name": "Itaca KR 32", "model_qualifier": "", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 29.4, "final_year_of_manufacture": null, "raw": ["016960", "000250", "0", "2012/Nov/29 13:04", "Fondital", "Fondital", "Itaca KR 32", "", "", "2012", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "29.4", "29.4", "", "", "89.2", "80.2", "", "58.6", "", "2", "1", "", "102", "1", "2", "121", "2.4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.2", "99.7", "", "", "", "", "97.7"]} -{"pcdb_id": 16961, "brand_name": "Fondital", "model_name": "Itaca KR 32", "model_qualifier": "", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 29.4, "final_year_of_manufacture": null, "raw": ["016961", "000250", "0", "2012/Nov/29 13:06", "Fondital", "Fondital", "Itaca KR 32", "", "", "2012", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "29.4", "29.4", "", "", "88.2", "79.2", "", "57.8", "", "2", "", "", "102", "1", "2", "121", "2.4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.2", "97.6", "", "", "", "", "95.6"]} -{"pcdb_id": 16962, "brand_name": "iQE", "model_name": "Simplicity", "model_qualifier": "20T", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 19.0, "final_year_of_manufacture": null, "raw": ["016962", "000273", "0", "2015/Oct/01 13:32", "Fonderie Sime S.p.A.", "iQE", "Simplicity", "20T", "41-283-35", "2012", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "19.0", "19.0", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "120", "8", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.2", "96.8", "", "", "", "", "95.1"]} -{"pcdb_id": 16963, "brand_name": "iQE", "model_name": "Simplicity", "model_qualifier": "20T", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 19.0, "final_year_of_manufacture": null, "raw": ["016963", "000273", "0", "2015/Oct/01 13:32", "Fonderie Sime S.p.A.", "iQE", "Simplicity", "20T", "", "2012", "current", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "19.0", "19.0", "", "", "89.0", "80.0", "", "58.5", "", "2", "1", "", "102", "1", "2", "120", "8", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.2", "98.9", "", "", "", "", "97.3"]} -{"pcdb_id": 16964, "brand_name": "iQE", "model_name": "Simplicity", "model_qualifier": "25", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 56.0, "output_kw_max": 23.9, "final_year_of_manufacture": null, "raw": ["016964", "000273", "0", "2015/Oct/01 13:33", "Fonderie Sime S.p.A.", "iQE", "Simplicity", "25", "47-283-41", "2009", "current", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "23.9", "23.9", "", "", "88.2", "79.6", "", "56.0", "", "2", "", "", "104", "1", "2", "125", "8", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.5", "97.1", "", "", "", "", "95.5"]} -{"pcdb_id": 16965, "brand_name": "iQE", "model_name": "Simplicity", "model_qualifier": "25", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 80.6, "comparative_hot_water_efficiency_pct": 56.7, "output_kw_max": 23.9, "final_year_of_manufacture": null, "raw": ["016965", "000273", "0", "2015/Oct/01 13:34", "Fonderie Sime S.p.A.", "iQE", "Simplicity", "25", "", "2009", "current", "2", "2", "1", "2", "0", "", "", "2", "3", "2", "23.9", "23.9", "", "", "89.2", "80.6", "", "56.7", "", "2", "1", "", "104", "1", "2", "125", "8", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.4", "99.3", "", "", "", "", "97.6"]} -{"pcdb_id": 16966, "brand_name": "iQE", "model_name": "Simplicity", "model_qualifier": "25T", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 23.9, "final_year_of_manufacture": null, "raw": ["016966", "000273", "0", "2015/Oct/01 13:35", "Fonderie Sime S.p.A.", "iQE", "Simplicity", "25T", "41-283-36", "2012", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "23.9", "23.9", "", "", "88.2", "79.2", "", "57.9", "", "2", "", "", "102", "1", "2", "125", "8", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.5", "97.1", "", "", "", "", "95.5"]} -{"pcdb_id": 16967, "brand_name": "iQE", "model_name": "Simplicity", "model_qualifier": "25T", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 23.9, "final_year_of_manufacture": null, "raw": ["016967", "000273", "0", "2015/Oct/01 13:35", "Fonderie Sime S.p.A.", "iQE", "Simplicity", "25T", "", "2012", "current", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "23.9", "23.9", "", "", "89.2", "80.2", "", "58.6", "", "2", "1", "", "102", "1", "2", "125", "8", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.4", "99.3", "", "", "", "", "97.6"]} -{"pcdb_id": 16968, "brand_name": "iQE", "model_name": "Simplicity", "model_qualifier": "30T", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": null, "final_year_of_manufacture": null, "raw": ["016968", "000273", "0", "2015/Oct/01 13:36", "Fonderie Sime S.p.A.", "iQE", "Simplicity", "30T", "41-283-37", "2012", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "28.9", ">70kW", "", "", "88.2", "79.2", "", "57.9", "", "2", "", "", "102", "1", "2", "130", "8", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.7", "97.0", "", "", "", "", "95.4"]} -{"pcdb_id": 16969, "brand_name": "iQE", "model_name": "Simplicity", "model_qualifier": "30T", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 28.9, "final_year_of_manufacture": null, "raw": ["016969", "000273", "0", "2015/Oct/01 13:37", "Fonderie Sime S.p.A.", "iQE", "Simplicity", "30T", "", "2012", "current", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "28.9", "28.9", "", "", "89.2", "80.2", "", "58.6", "", "2", "1", "", "102", "1", "2", "130", "8", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.6", "99.2", "", "", "", "", "97.6"]} -{"pcdb_id": 16970, "brand_name": "iQE", "model_name": "Simplicity", "model_qualifier": "30", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 56.0, "output_kw_max": 28.9, "final_year_of_manufacture": null, "raw": ["016970", "000273", "0", "2015/Oct/01 13:39", "Fonderie Sime S.p.A.", "iQE", "Simplicity", "30", "47-283-42", "2012", "current", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "28.9", "28.9", "", "", "88.2", "79.6", "", "56.0", "", "2", "", "", "104", "1", "2", "130", "8", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.7", "97.0", "", "", "", "", "95.4"]} -{"pcdb_id": 16971, "brand_name": "iQE", "model_name": "Simplicity", "model_qualifier": "30", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 80.6, "comparative_hot_water_efficiency_pct": 56.7, "output_kw_max": 28.9, "final_year_of_manufacture": null, "raw": ["016971", "000273", "0", "2015/Oct/01 13:40", "Fonderie Sime S.p.A.", "iQE", "Simplicity", "30", "", "2012", "current", "2", "2", "1", "2", "0", "", "", "2", "3", "2", "28.9", "28.9", "", "", "89.2", "80.6", "", "56.7", "", "2", "1", "", "104", "1", "2", "130", "8", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.6", "99.2", "", "", "", "", "97.6"]} -{"pcdb_id": 16972, "brand_name": "iQE", "model_name": "Simplicity", "model_qualifier": "35", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 55.8, "output_kw_max": 34.1, "final_year_of_manufacture": null, "raw": ["016972", "000273", "0", "2015/Oct/01 13:41", "Fonderie Sime S.p.A.", "iQE", "Simplicity", "35", "47-283-43", "2012", "current", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "34.1", "34.1", "", "", "88.0", "79.4", "", "55.8", "", "2", "", "", "104", "1", "2", "140", "8", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.5", "96.2", "", "", "", "", "94.9"]} -{"pcdb_id": 16973, "brand_name": "iQE", "model_name": "Simplicity", "model_qualifier": "35", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.4, "comparative_hot_water_efficiency_pct": 56.6, "output_kw_max": 34.1, "final_year_of_manufacture": null, "raw": ["016973", "000273", "0", "2015/Oct/01 13:43", "Fonderie Sime S.p.A.", "iQE", "Simplicity", "35", "", "2012", "current", "2", "2", "1", "2", "0", "", "", "2", "3", "2", "34.1", "34.1", "", "", "89.0", "80.4", "", "56.6", "", "2", "1", "", "104", "1", "2", "140", "8", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "91.5", "98.4", "", "", "", "", "97.1"]} -{"pcdb_id": 16974, "brand_name": "Vokera", "model_name": "Vision", "model_qualifier": "20S", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 19.5, "final_year_of_manufacture": null, "raw": ["016974", "000011", "0", "2012/Nov/07 12:42", "Vokera", "Vokera", "Vision", "20S", "41 094 76", "2012", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "19.50", "19.50", "", "", "88.5", "79.5", "", "58.1", "", "2", "", "", "102", "1", "2", "96", "4.5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "87.8", "98.1", "", "", "", "", "96.2"]} -{"pcdb_id": 16975, "brand_name": "Vokera", "model_name": "Vision", "model_qualifier": "25S", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 24.45, "final_year_of_manufacture": null, "raw": ["016975", "000011", "0", "2012/Nov/07 12:43", "Vokera", "Vokera", "Vision", "25S", "41 094 77", "2012", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "24.45", "24.45", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "107", "4.5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "88.1", "97.7", "", "", "", "", "95.9"]} -{"pcdb_id": 16976, "brand_name": "Vokera", "model_name": "Vision", "model_qualifier": "25C", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 86.6, "comparative_hot_water_efficiency_pct": 72.0, "output_kw_max": 19.5, "final_year_of_manufacture": null, "raw": ["016976", "000011", "0", "2014/Oct/15 10:57", "Vokera", "Vokera", "Vision", "25C", "47 364 10", "2012", "current", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "19.5", "19.5", "", "", "88.5", "86.6", "", "72.0", "", "2", "", "", "104", "1", "2", "110", "4.5", "0", "", "", "", "0", "", "", "", "", "1", "7.315", "0.105", "0.003", "1.17113", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "", "", "", "", "87.8", "98.1", "", "", "", "", "96.2"]} -{"pcdb_id": 16977, "brand_name": "Vokera", "model_name": "Vision", "model_qualifier": "30C", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 86.7, "comparative_hot_water_efficiency_pct": 71.9, "output_kw_max": 24.45, "final_year_of_manufacture": null, "raw": ["016977", "000011", "0", "2014/Oct/15 10:58", "Vokera", "Vokera", "Vision", "30C", "47 364 11", "2012", "current", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "24.45", "24.45", "", "", "88.4", "86.7", "", "71.9", "", "2", "", "", "104", "1", "2", "119", "4.5", "0", "", "", "", "0", "", "", "", "", "1", "7.325", "0.103", "0.003", "1.18793", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "", "", "", "", "88.1", "97.7", "", "", "", "", "95.9"]} -{"pcdb_id": 16978, "brand_name": "Sime", "model_name": "Brava DGT HE", "model_qualifier": "35", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 56.2, "output_kw_max": 34.1, "final_year_of_manufacture": 2018, "raw": ["016978", "000213", "0", "2018/Feb/26 16:35", "Fonderie Sime S.p.A.", "Sime", "Brava DGT HE", "35", "47-283-40", "2012", "2018", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "34.1", "34.1", "", "", "88.5", "79.9", "", "56.2", "", "2", "", "", "104", "1", "2", "135", "4.9", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.7", "97.8", "", "", "", "", "96.0"]} -{"pcdb_id": 16979, "brand_name": "Sime", "model_name": "Brava DGT HE", "model_qualifier": "35", "winter_efficiency_pct": 89.5, "summer_efficiency_pct": 80.9, "comparative_hot_water_efficiency_pct": 56.9, "output_kw_max": 34.1, "final_year_of_manufacture": 2018, "raw": ["016979", "000213", "0", "2018/Feb/26 16:34", "Fonderie Sime S.p.A.", "Sime", "Brava DGT HE", "35", "", "2012", "2018", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "34.1", "34.1", "", "", "89.5", "80.9", "", "56.9", "", "2", "1", "", "104", "1", "2", "135", "4.9", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.7", "99.9", "", "", "", "", "98.2"]} -{"pcdb_id": 16980, "brand_name": "Johnson & Starley", "model_name": "QuanTec", "model_qualifier": "HR28C", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 86.6, "comparative_hot_water_efficiency_pct": 85.4, "output_kw_max": 21.1, "final_year_of_manufacture": null, "raw": ["016980", "000239", "0", "2015/Sep/22 16:29", "Johnson & Starley", "Johnson & Starley", "QuanTec", "HR28C", "47-416-11", "2012", "current", "1", "2", "1", "2", "1", "", "", "2", "2", "2", "21.1", "21.1", "", "", "88.7", "86.6", "", "85.4", "", "2", "", "", "104", "1", "2", "100", "2.17", "0", "", "", "", "0", "", "", "", "", "1", "6.1677", "0.1349", "0.0044", "0.06006", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "", "", "", "", "87.8", "98.7", "", "", "", "", "96.7"]} -{"pcdb_id": 16982, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "32 CDi Compact", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 87.9, "comparative_hot_water_efficiency_pct": 72.7, "output_kw_max": 24.0, "final_year_of_manufacture": 2015, "raw": ["016982", "000035", "0", "2020/Sep/08 10:37", "Bosch Thermotechnology", "Worcester", "Greenstar", "32 CDi Compact", "47-406-46", "2012", "2015", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "89.2", "87.9", "", "72.7", "", "2", "", "", "104", "1", "2", "121", "1.0", "0", "", "", "", "0", "", "", "", "", "2", "7.24", "0.088", "0.0017", "1.13266", "13.19", "0.109", "0.0006", "1.06911", "0.00001", "1", "1", "", "0305", "", "", "", "", "", "", "", "", "88.8", "99.6", "", "", "", "", "97.5"]} -{"pcdb_id": 16983, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "28 CDi Compact", "winter_efficiency_pct": 90.3, "summer_efficiency_pct": 90.3, "comparative_hot_water_efficiency_pct": 74.7, "output_kw_max": 24.0, "final_year_of_manufacture": 2015, "raw": ["016983", "000035", "0", "2020/Sep/08 10:37", "Bosch Thermotechnology", "Worcester", "Greenstar", "28 CDi Compact", "47-406-45", "2012", "2015", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "90.3", "90.3", "", "74.7", "", "2", "1", "", "104", "1", "2", "108", "1.0", "0", "", "", "", "0", "", "", "", "", "2", "7.21", "0.087", "0.0014", "1.10575", "13.13", "0.107", "0.0009", "1.07482", "0.0", "1", "1", "", "0305", "", "", "", "", "", "", "", "", "90.8", "101.8", "", "", "", "", "99.7"]} -{"pcdb_id": 16984, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "32 CDi Compact", "winter_efficiency_pct": 90.3, "summer_efficiency_pct": 90.3, "comparative_hot_water_efficiency_pct": 73.7, "output_kw_max": 24.0, "final_year_of_manufacture": 2015, "raw": ["016984", "000035", "0", "2020/Sep/08 10:37", "Bosch Thermotechnology", "Worcester", "Greenstar", "32 CDi Compact", "47-406-47", "2012", "2015", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "90.3", "90.3", "", "73.7", "", "2", "1", "", "104", "1", "2", "120", "1.0", "0", "", "", "", "0", "", "", "", "", "2", "7.3", "0.089", "0.0007", "1.19641", "13.15", "0.106", "0.0008", "1.16509", "0.0", "1", "1", "", "0305", "", "", "", "", "", "", "", "", "90.8", "101.8", "", "", "", "", "99.7"]} -{"pcdb_id": 16985, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "36 CDi Compact", "winter_efficiency_pct": 90.3, "summer_efficiency_pct": 90.3, "comparative_hot_water_efficiency_pct": 73.4, "output_kw_max": 24.0, "final_year_of_manufacture": 2015, "raw": ["016985", "000035", "0", "2020/Sep/08 10:38", "Bosch Thermotechnology", "Worcester", "Greenstar", "36 CDi Compact", "47-406-49", "2012", "2015", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "90.3", "90.3", "", "73.4", "", "2", "1", "", "104", "1", "2", "134", "1.0", "0", "", "", "", "0", "", "", "", "", "2", "7.33", "0.088", "0.0021", "1.21747", "13.17", "0.107", "0.0008", "1.18603", "0.00001", "1", "1", "", "0305", "", "", "", "", "", "", "", "", "90.8", "101.8", "", "", "", "", "99.7"]} -{"pcdb_id": 16986, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "28 CDi Compact", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 87.5, "comparative_hot_water_efficiency_pct": 73.9, "output_kw_max": 24.0, "final_year_of_manufacture": 2015, "raw": ["016986", "000035", "0", "2020/Sep/08 10:38", "Bosch Thermotechnology", "Worcester", "Greenstar", "28 CDi Compact", "47-406-44", "2012", "2015", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "89.2", "87.5", "", "73.9", "", "2", "", "", "104", "1", "2", "108", "1.0", "0", "", "", "", "0", "", "", "", "", "2", "7.13", "0.087", "0.0014", "1.02854", "13.11", "0.108", "0.0007", "0.93618", "0.00001", "1", "1", "", "0305", "", "", "", "", "", "", "", "", "88.8", "99.6", "", "", "", "", "97.5"]} -{"pcdb_id": 16987, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "36 CDi Compact", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 88.2, "comparative_hot_water_efficiency_pct": 72.4, "output_kw_max": 24.0, "final_year_of_manufacture": 2015, "raw": ["016987", "000035", "0", "2020/Apr/09 16:29", "Bosch Thermotechnology", "Worcester", "Greenstar", "36 CDi Compact", "47-406-48", "2012", "2015", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "89.2", "88.2", "", "72.4", "", "2", "", "", "104", "1", "2", "130", "1.0", "0", "", "", "", "0", "", "", "", "", "2", "7.27", "0.088", "0.0011", "1.16541", "12.54", "0.099", "0.0017", "1.12322", "-0.00001", "1", "1", "", "0305", "", "", "", "", "", "", "", "", "88.8", "99.6", "", "", "", "", "97.5"]} -{"pcdb_id": 16988, "brand_name": "Baxi", "model_name": "Neta-tec Plus", "model_qualifier": "24 GA", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 77.6, "output_kw_max": 20.0, "final_year_of_manufacture": 2015, "raw": ["016988", "000005", "0", "2015/Aug/06 12:10", "Baxi", "Baxi", "Neta-tec Plus", "24 GA", "", "2011", "2015", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "20", "20", "", "", "88.4", "87.3", "", "77.6", "", "2", "", "", "104", "1", "2", "104", "3.5", "0", "", "", "", "0", "", "", "", "", "1", "6.786", "0.118", "0.0043", "0.70793", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "90.0", "96.9", "", "", "", "", "95.6"]} -{"pcdb_id": 16989, "brand_name": "Baxi", "model_name": "Neta-tec Plus", "model_qualifier": "28 GA", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 77.3, "output_kw_max": 24.0, "final_year_of_manufacture": 2015, "raw": ["016989", "000005", "0", "2015/Aug/06 12:11", "Baxi Heating UK", "Baxi", "Neta-tec Plus", "28 GA", "", "", "2015", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "88.4", "87.3", "", "77.3", "", "2", "", "", "104", "1", "2", "116", "3.5", "0", "", "", "", "0", "", "", "", "", "1", "6.813", "0.118", "0.0044", "0.73349", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "90.0", "96.9", "", "", "", "", "95.6"]} -{"pcdb_id": 16990, "brand_name": "Baxi", "model_name": "Neta-tec Plus", "model_qualifier": "33 GA", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 77.2, "output_kw_max": 28.0, "final_year_of_manufacture": 2015, "raw": ["016990", "000005", "0", "2015/Aug/06 12:11", "Baxi Heating UK", "Baxi", "Neta-tec Plus", "33 GA", "", "2011", "2015", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28", "28", "", "", "88.4", "87.3", "", "77.2", "", "2", "", "", "104", "1", "2", "133", "3.5", "0", "", "", "", "0", "", "", "", "", "1", "6.821", "0.106", "0.0045", "0.74098", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "90.0", "97.0", "", "", "", "", "95.7"]} -{"pcdb_id": 16991, "brand_name": "Baxi", "model_name": "Neta-tec Plus", "model_qualifier": "24 GA", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 56.8, "output_kw_max": 20.0, "final_year_of_manufacture": null, "raw": ["016991", "000005", "0", "2012/Nov/29 08:50", "Baxi Heating UK", "Baxi", "Neta-tec Plus", "24 GA", "", "2011", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "20", "20", "", "", "89.4", "80.8", "", "56.8", "", "2", "1", "", "104", "1", "2", "104", "3.5", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "92.0", "99.1", "", "", "", "", "97.8"]} -{"pcdb_id": 16992, "brand_name": "Baxi", "model_name": "Neta-tec Plus", "model_qualifier": "28 GA", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 56.8, "output_kw_max": 24.0, "final_year_of_manufacture": null, "raw": ["016992", "000005", "0", "2012/Nov/29 08:50", "Baxi Heating UK", "Baxi", "Neta-tec Plus", "28 GA", "", "2011", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "89.4", "80.8", "", "56.8", "", "2", "1", "", "104", "1", "2", "116", "3.5", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "92.0", "99.1", "", "", "", "", "97.8"]} -{"pcdb_id": 16993, "brand_name": "Baxi", "model_name": "Neta-tec Plus", "model_qualifier": "33 GA", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 56.8, "output_kw_max": 28.0, "final_year_of_manufacture": null, "raw": ["016993", "000005", "0", "2012/Nov/29 08:51", "Baxi Heating UK", "Baxi", "Neta-tec Plus", "33 GA", "", "2011", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "28", "28", "", "", "89.4", "80.8", "", "56.8", "", "2", "1", "", "104", "1", "2", "133", "3.5", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "92.0", "99.2", "", "", "", "", "97.8"]} -{"pcdb_id": 16994, "brand_name": "Viessmann", "model_name": "Vitodens 100-W", "model_qualifier": "WB1C 19kW System Boiler", "winter_efficiency_pct": 89.5, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 58.8, "output_kw_max": 17.3, "final_year_of_manufacture": 2015, "raw": ["016994", "000033", "0", "2013/Sep/20 08:26", "Viessmann", "Viessmann", "Vitodens 100-W", "WB1C 19kW System Boiler", "", "2012", "2015", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "17.3", "17.3", "", "", "89.5", "80.5", "", "58.8", "", "2", "1", "", "102", "1", "2", "77.0", "4.92", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.2", "100.1", "", "", "", "", "98.2"]} -{"pcdb_id": 16995, "brand_name": "Viessmann", "model_name": "Vitodens 100-W", "model_qualifier": "WB1C 19kW System Boiler", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 17.3, "final_year_of_manufacture": 2015, "raw": ["016995", "000033", "0", "2013/Sep/20 08:25", "Viessmann", "Viessmann", "Vitodens 100-W", "WB1C 19kW System Boiler", "", "2012", "2015", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "17.3", "17.3", "", "", "88.5", "79.5", "", "58.1", "", "2", "", "", "102", "1", "2", "77.0", "4.92", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.2", "97.9", "", "", "", "", "96.1"]} -{"pcdb_id": 16996, "brand_name": "Viessmann", "model_name": "Vitodens 100-W", "model_qualifier": "WB1C 35kW System Boiler", "winter_efficiency_pct": 89.7, "summer_efficiency_pct": 80.7, "comparative_hot_water_efficiency_pct": 59.0, "output_kw_max": 31.9, "final_year_of_manufacture": 2015, "raw": ["016996", "000033", "0", "2013/Sep/20 08:14", "Viessmann", "Viessmann", "Vitodens 100-W", "WB1C 35kW System Boiler", "", "2012", "2015", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "31.9", "31.9", "", "", "89.7", "80.7", "", "59.0", "", "2", "1", "", "102", "1", "2", "143", "4.76", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.2", "100.7", "", "", "", "", "98.7"]} -{"pcdb_id": 16997, "brand_name": "Viessmann", "model_name": "Vitodens 100-W", "model_qualifier": "WB1C 35kW System Boiler", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 31.9, "final_year_of_manufacture": 2015, "raw": ["016997", "000033", "0", "2013/Sep/20 08:14", "Viessmann", "Viessmann", "Vitodens 100-W", "WB1C 35kW System Boiler", "", "2012", "2015", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "31.9", "31.9", "", "", "88.7", "79.7", "", "58.2", "", "2", "", "", "102", "1", "2", "143", "4.76", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.2", "98.5", "", "", "", "", "96.5"]} -{"pcdb_id": 16998, "brand_name": "Viessmann", "model_name": "Vitodens 100-W", "model_qualifier": "WB1C 26kW System Boiler", "winter_efficiency_pct": 89.5, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 58.8, "output_kw_max": 23.7, "final_year_of_manufacture": 2015, "raw": ["016998", "000033", "0", "2013/Sep/20 08:23", "Viessmann", "Viessmann", "Vitodens 100-W", "WB1C 26kW System Boiler", "", "2012", "2015", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "23.7", "23.7", "", "", "89.5", "80.5", "", "58.8", "", "2", "1", "", "102", "1", "2", "87.3", "4.92", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.3", "100.0", "", "", "", "", "98.2"]} -{"pcdb_id": 16999, "brand_name": "Viessmann", "model_name": "Vitodens 100-W", "model_qualifier": "WB1C 26kW System Boiler", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 23.7, "final_year_of_manufacture": 2015, "raw": ["016999", "000033", "0", "2013/Sep/20 08:23", "Viessmann", "Viessmann", "Vitodens 100-W", "WB1C 26kW System Boiler", "", "2012", "2015", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "23.7", "23.7", "", "", "88.5", "79.5", "", "58.0", "", "2", "", "", "102", "1", "2", "87.3", "4.92", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "97.8", "", "", "", "", "96.0"]} -{"pcdb_id": 17000, "brand_name": "Viessmann", "model_name": "Vitodens 100-W", "model_qualifier": "WB1C 26kW Combi Boiler", "winter_efficiency_pct": 89.5, "summer_efficiency_pct": 80.9, "comparative_hot_water_efficiency_pct": 56.9, "output_kw_max": 23.7, "final_year_of_manufacture": 2015, "raw": ["017000", "000033", "0", "2013/Sep/20 08:25", "Viessmann", "Viessmann", "Vitodens 100-W", "WB1C 26kW Combi Boiler", "", "2012", "2015", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "23.7", "23.7", "", "", "89.5", "80.9", "", "56.9", "", "2", "1", "", "104", "1", "2", "87.3", "4.92", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.3", "100.0", "", "", "", "", "98.2"]} -{"pcdb_id": 17001, "brand_name": "Viessmann", "model_name": "Vitodens 100-W", "model_qualifier": "WB1C 26kW Combi Boiler", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 88.2, "comparative_hot_water_efficiency_pct": 70.3, "output_kw_max": 23.7, "final_year_of_manufacture": 2015, "raw": ["017001", "000033", "0", "2020/Apr/09 16:23", "Viessmann", "Viessmann", "Vitodens 100-W", "WB1C 26kW Combi Boiler", "", "2012", "2015", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "23.7", "23.7", "", "", "88.5", "88.2", "", "70.3", "", "2", "", "", "104", "1", "2", "87.3", "4.92", "0", "", "", "", "0", "", "", "", "", "2", "7.489", "0.174", "0.0065", "1.33028", "13.26", "0.199", "0.0016", "1.30152", "0.00005", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "97.8", "", "", "", "", "96.0"]} -{"pcdb_id": 17002, "brand_name": "Viessmann", "model_name": "Vitodens 100-W", "model_qualifier": "WB1C 30kW System Boiler", "winter_efficiency_pct": 89.3, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 58.7, "output_kw_max": 27.3, "final_year_of_manufacture": 2015, "raw": ["017002", "000033", "0", "2013/Sep/20 08:21", "Viessmann", "Viessmann", "Vitodens 100-W", "WB1C 30kW System Boiler", "", "2012", "2015", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "27.3", "27.3", "", "", "89.3", "80.3", "", "58.7", "", "2", "1", "", "102", "1", "2", "93.6", "4.76", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.3", "99.7", "", "", "", "", "97.9"]} -{"pcdb_id": 17003, "brand_name": "Viessmann", "model_name": "Vitodens 100-W", "model_qualifier": "WB1C 30kW System Boiler", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 27.3, "final_year_of_manufacture": 2015, "raw": ["017003", "000033", "0", "2015/Nov/02 11:33", "Viessmann", "Viessmann", "Vitodens 100-W", "WB1C 30kW System Boiler", "", "2012", "2015", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "27.3", "27.3", "", "", "88.3", "79.3", "", "57.9", "", "2", "", "", "102", "1", "2", "93.6", "4.76", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "97.5", "", "", "", "", "95.7"]} -{"pcdb_id": 17004, "brand_name": "Viessmann", "model_name": "Vitodens 100-W", "model_qualifier": "WB1C 35kW Combi Boiler", "winter_efficiency_pct": 89.7, "summer_efficiency_pct": 81.1, "comparative_hot_water_efficiency_pct": 57.0, "output_kw_max": 31.9, "final_year_of_manufacture": 2015, "raw": ["017004", "000033", "0", "2013/Sep/20 08:18", "Viessmann", "Viessmann", "Vitodens 100-W", "WB1C 35kW Combi Boiler", "", "2012", "2015", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "31.9", "31.9", "", "", "89.7", "81.1", "", "57.0", "", "2", "1", "", "104", "1", "2", "143", "4.76", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.2", "100.7", "", "", "", "", "98.7"]} -{"pcdb_id": 17005, "brand_name": "Viessmann", "model_name": "Vitodens 100-W", "model_qualifier": "WB1C 35kW Combi", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 88.2, "comparative_hot_water_efficiency_pct": 72.5, "output_kw_max": 31.9, "final_year_of_manufacture": 2015, "raw": ["017005", "000033", "0", "2020/Apr/09 16:23", "Viessmann", "Viessmann", "Vitodens 100-W", "WB1C 35kW Combi", "", "2012", "2015", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "31.9", "31.9", "", "", "88.7", "88.2", "", "72.5", "", "2", "", "", "104", "1", "2", "143", "4.76", "0", "", "", "0", "0", "", "", "", "", "2", "7.265", "0.194", "0.0025", "1.13548", "13.113", "0.221", "0.0006", "1.10995", "0.00002", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.2", "98.5", "", "", "", "", "96.5"]} -{"pcdb_id": 17006, "brand_name": "Viessmann", "model_name": "Vitodens 100-W WB1B", "model_qualifier": "35kW Regular Boiler Open Vent", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 31.9, "final_year_of_manufacture": null, "raw": ["017006", "000033", "0", "2017/Feb/20 10:57", "Viessmann", "Viessmann", "Vitodens 100-W WB1B", "35kW Regular Boiler Open Vent", "", "2012", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "31.9", "31.9", "", "", "89.0", "80.0", "", "58.5", "", "2", "1", "", "102", "1", "2", "143", "4.76", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "", "", "", "", "89.8", "99.1", "", "", "", "", "97.3"]} -{"pcdb_id": 17007, "brand_name": "Viessmann", "model_name": "Vitodens 100W WB1B", "model_qualifier": "35kW Regular Boiler Open Vent", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 31.9, "final_year_of_manufacture": null, "raw": ["017007", "000033", "0", "2017/Feb/20 10:57", "Viessmann", "Viessmann", "Vitodens 100W WB1B", "35kW Regular Boiler Open Vent", "", "2012", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "31.9", "31.9", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "143", "4.76", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "", "", "", "", "87.8", "96.9", "", "", "", "", "95.2"]} -{"pcdb_id": 17008, "brand_name": "Viessmann", "model_name": "Vitodens 111-W", "model_qualifier": "B1LA 26kW", "winter_efficiency_pct": 89.5, "summer_efficiency_pct": 82.2, "comparative_hot_water_efficiency_pct": 44.5, "output_kw_max": 23.7, "final_year_of_manufacture": 2016, "raw": ["017008", "000033", "0", "2024/Jan/31 10:17", "Viessmann", "Viessmann", "Vitodens 111-W", "B1LA 26kW", "", "2012", "2016", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "23.7", "23.7", "", "", "89.5", "82.2", "", "44.5", "", "2", "1", "0", "106", "1", "2", "160", "2.11", "1", "", "", "46", "0", "25", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.3", "100.0", "", "", "", "", "98.2"]} -{"pcdb_id": 17009, "brand_name": "Viessmann", "model_name": "Vitodens 111-W", "model_qualifier": "B1LA 26kW", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 81.2, "comparative_hot_water_efficiency_pct": 44.0, "output_kw_max": 23.7, "final_year_of_manufacture": 2016, "raw": ["017009", "000033", "0", "2024/Jan/31 10:17", "Viessmann", "Viessmann", "Vitodens 111-W", "B1LA 26kW", "", "2012", "2016", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "23.7", "23.7", "", "", "88.5", "81.2", "", "44.0", "", "2", "", "", "106", "1", "2", "160", "2.11", "1", "", "", "46", "0", "25", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "97.8", "", "", "", "", "96.0"]} -{"pcdb_id": 17010, "brand_name": "Viessmann", "model_name": "Vitodens 111-W", "model_qualifier": "B1LA 35kW", "winter_efficiency_pct": 89.7, "summer_efficiency_pct": 82.4, "comparative_hot_water_efficiency_pct": 44.7, "output_kw_max": 31.9, "final_year_of_manufacture": 2016, "raw": ["017010", "000033", "0", "2024/Jan/31 10:17", "Viessmann", "Viessmann", "Vitodens 111-W", "B1LA 35kW", "", "2012", "2016", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "31.9", "31.9", "", "", "89.7", "82.4", "", "44.7", "", "2", "1", "", "106", "1", "2", "160", "2.11", "1", "", "", "46", "0", "25", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.2", "100.7", "", "", "", "", "98.7"]} -{"pcdb_id": 17011, "brand_name": "Viessmann", "model_name": "Vitodens 111-W", "model_qualifier": "B1LA 35kW", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 81.4, "comparative_hot_water_efficiency_pct": 44.1, "output_kw_max": 31.9, "final_year_of_manufacture": 2016, "raw": ["017011", "000033", "0", "2024/Jan/31 10:17", "Viessmann", "Viessmann", "Vitodens 111-W", "B1LA 35kW", "", "2012", "2016", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "31.9", "31.9", "", "", "88.7", "81.4", "", "44.1", "", "2", "", "", "106", "1", "2", "160", "2.11", "1", "", "", "46", "0", "25", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.2", "98.5", "", "", "", "", "96.5"]} -{"pcdb_id": 17012, "brand_name": "Viessmann", "model_name": "Vitodens 100-W", "model_qualifier": "WB1C 30kW Combi Boiler", "winter_efficiency_pct": 89.3, "summer_efficiency_pct": 80.7, "comparative_hot_water_efficiency_pct": 56.8, "output_kw_max": 27.3, "final_year_of_manufacture": 2015, "raw": ["017012", "000033", "0", "2013/Sep/20 08:22", "Viessmann", "Viessmann", "Vitodens 100-W", "WB1C 30kW Combi Boiler", "", "2012", "2015", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "27.3", "27.3", "", "", "89.3", "80.7", "", "56.8", "", "2", "1", "", "104", "1", "2", "93.6", "4.76", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.3", "99.7", "", "", "", "", "97.9"]} -{"pcdb_id": 17013, "brand_name": "Viessmann", "model_name": "Vitodens 100-W", "model_qualifier": "WB1C 30kW Combi Boiler", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 87.8, "comparative_hot_water_efficiency_pct": 72.0, "output_kw_max": 27.3, "final_year_of_manufacture": 2015, "raw": ["017013", "000033", "0", "2020/Apr/09 16:22", "Viessmann", "Viessmann", "Vitodens 100-W", "WB1C 30kW Combi Boiler", "", "2012", "2015", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "27.3", "27.3", "", "", "88.3", "87.8", "", "72.0", "", "2", "", "", "104", "1", "2", "93.6", "4.76", "0", "", "", "0", "0", "", "", "", "", "2", "7.314", "0.187", "0.0393", "0.96995", "13.051", "0.212", "0.001", "0.91208", "0.00038", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "97.5", "", "", "", "", "95.7"]} -{"pcdb_id": 17014, "brand_name": "Viessmann", "model_name": "Vitodens 100-W", "model_qualifier": "BPJA 25kW P29", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 56.2, "output_kw_max": 22.8, "final_year_of_manufacture": 2015, "raw": ["017014", "000033", "0", "2013/Sep/20 08:27", "Viessmann", "Viessmann", "Vitodens 100-W", "BPJA 25kW P29", "", "2012", "2015", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "22.8", "22.8", "", "", "88.5", "79.9", "", "56.2", "", "2", "", "", "104", "1", "2", "92.0", "4.76", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.5", "97.9", "", "", "", "", "96.1"]} -{"pcdb_id": 17015, "brand_name": "Viessmann", "model_name": "Vitodens 100-W", "model_qualifier": "BPJA 25 kW P29", "winter_efficiency_pct": 89.5, "summer_efficiency_pct": 80.9, "comparative_hot_water_efficiency_pct": 56.9, "output_kw_max": 22.8, "final_year_of_manufacture": 2015, "raw": ["017015", "000033", "0", "2013/Sep/20 08:27", "Viessmann", "Viessmann", "Vitodens 100-W", "BPJA 25 kW P29", "", "2012", "2015", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "22.8", "22.8", "", "", "89.5", "80.9", "", "56.9", "", "2", "1", "", "104", "1", "2", "92.0", "4.76", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.4", "100.1", "", "", "", "", "98.3"]} -{"pcdb_id": 17016, "brand_name": "Viessmann", "model_name": "Vitodens 100-W", "model_qualifier": "BPJA 21kW P25", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 56.2, "output_kw_max": 19.1, "final_year_of_manufacture": 2015, "raw": ["017016", "000033", "0", "2013/Sep/20 08:28", "Viessmann", "Viessmann", "Vitodens 100-W", "BPJA 21kW P25", "", "2012", "2015", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "19.1", "19.1", "", "", "88.5", "79.9", "", "56.2", "", "2", "", "", "104", "1", "2", "85.0", "4.76", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.2", "97.9", "", "", "", "", "96.1"]} -{"pcdb_id": 17017, "brand_name": "Viessmann", "model_name": "Vitodens 100-W", "model_qualifier": "BPJA 21kW P25", "winter_efficiency_pct": 89.5, "summer_efficiency_pct": 80.9, "comparative_hot_water_efficiency_pct": 56.9, "output_kw_max": 19.1, "final_year_of_manufacture": 2015, "raw": ["017017", "000033", "0", "2013/Sep/20 08:30", "Viessmann", "Viessmann", "Vitodens 100-W", "BPJA 21kW P25", "", "2012", "2015", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "19.1", "19.1", "", "", "89.5", "80.9", "", "56.9", "", "2", "1", "", "104", "1", "2", "85.0", "4.76", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.2", "100.1", "", "", "", "", "98.2"]} -{"pcdb_id": 17018, "brand_name": "Rhino Savannah", "model_name": "RH15/20 Heatpac", "model_qualifier": "", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 81.4, "comparative_hot_water_efficiency_pct": 59.5, "output_kw_max": 20.0, "final_year_of_manufacture": null, "raw": ["017018", "000223", "0", "2013/Aug/29 14:35", "Firebird Boilers", "Rhino Savannah", "RH15/20 Heatpac", "", "", "2012", "current", "4", "1", "2", "1", "0", "", "", "2", "1", "1", "15", "20", "", "", "89.2", "81.4", "", "59.5", "", "2", "", "", "201", "1", "1", "38", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "93.0", "97.0", "", "", "", "", "96.2"]} -{"pcdb_id": 17019, "brand_name": "Rhino Savannah", "model_name": "RB 15/20 Boilerhouse", "model_qualifier": "", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 81.4, "comparative_hot_water_efficiency_pct": 59.5, "output_kw_max": 20.0, "final_year_of_manufacture": null, "raw": ["017019", "000223", "0", "2013/Aug/29 14:35", "Firebird Boilers", "Rhino Savannah", "RB 15/20 Boilerhouse", "", "", "2012", "current", "4", "1", "1", "1", "0", "", "", "2", "2", "1", "15", "20", "", "", "89.2", "81.4", "", "59.5", "", "2", "", "", "201", "1", "1", "38", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "93.0", "97.0", "", "", "", "", "96.2"]} -{"pcdb_id": 17020, "brand_name": "Rhino Savannah", "model_name": "R15/20 Kitchen", "model_qualifier": "", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 81.4, "comparative_hot_water_efficiency_pct": 59.5, "output_kw_max": 20.0, "final_year_of_manufacture": null, "raw": ["017020", "000223", "0", "2013/Aug/29 14:35", "Firebird Boilers", "Rhino Savannah", "R15/20 Kitchen", "", "", "2012", "current", "4", "1", "1", "1", "0", "", "", "2", "2", "1", "15", "20", "", "", "89.2", "81.4", "", "59.5", "", "2", "", "", "201", "1", "1", "38", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "93.0", "97.0", "", "", "", "", "96.2"]} -{"pcdb_id": 17021, "brand_name": "Rhino Savannah", "model_name": "RC15/20 Combi Boiler", "model_qualifier": "", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 81.8, "comparative_hot_water_efficiency_pct": 57.5, "output_kw_max": 20.0, "final_year_of_manufacture": null, "raw": ["017021", "000223", "0", "2013/Aug/29 14:35", "Firebird Boilers", "Rhino Savannah", "RC15/20 Combi Boiler", "", "", "2012", "current", "4", "1", "1", "2", "0", "", "", "2", "2", "1", "15", "20", "", "", "89.2", "81.8", "", "57.5", "", "2", "", "", "202", "1", "1", "38", "0", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "93.0", "97.0", "", "", "", "", "96.2"]} -{"pcdb_id": 17022, "brand_name": "Rhino Savannah", "model_name": "RP15/20 Combipac", "model_qualifier": "", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 81.8, "comparative_hot_water_efficiency_pct": 57.5, "output_kw_max": 20.0, "final_year_of_manufacture": null, "raw": ["017022", "000223", "0", "2013/Aug/29 14:35", "Firebird Boilers", "Rhino Savannah", "RP15/20 Combipac", "", "", "2012", "current", "4", "1", "2", "2", "0", "", "", "2", "1", "1", "15", "20", "", "", "89.2", "81.8", "", "57.5", "", "2", "", "", "202", "1", "1", "38", "0", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "93.0", "97.0", "", "", "", "", "96.2"]} -{"pcdb_id": 17023, "brand_name": "Rhino Savannah", "model_name": "RH20/26 Heatpac", "model_qualifier": "", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 81.4, "comparative_hot_water_efficiency_pct": 59.5, "output_kw_max": 26.0, "final_year_of_manufacture": null, "raw": ["017023", "000223", "0", "2013/Aug/29 14:35", "Firebird Boilers", "Rhino Savannah", "RH20/26 Heatpac", "", "", "2012", "current", "4", "1", "2", "1", "0", "", "", "2", "1", "1", "20", "26", "", "", "89.2", "81.4", "", "59.5", "", "2", "", "", "201", "1", "1", "38", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "93.1", "96.9", "", "", "", "", "96.2"]} -{"pcdb_id": 17024, "brand_name": "Rhino Savannah", "model_name": "RB20/26 Boilerhouse", "model_qualifier": "", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 81.4, "comparative_hot_water_efficiency_pct": 59.5, "output_kw_max": 26.0, "final_year_of_manufacture": null, "raw": ["017024", "000223", "0", "2013/Aug/29 14:35", "Firebird Boilers", "Rhino Savannah", "RB20/26 Boilerhouse", "", "", "2012", "current", "4", "1", "1", "1", "0", "", "", "2", "2", "1", "20", "26", "", "", "89.2", "81.4", "", "59.5", "", "2", "", "", "201", "1", "1", "38", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "93.1", "96.9", "", "", "", "", "96.2"]} -{"pcdb_id": 17025, "brand_name": "Rhino Savannah", "model_name": "R20/26 Kitchen", "model_qualifier": "", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 81.4, "comparative_hot_water_efficiency_pct": 59.5, "output_kw_max": 26.0, "final_year_of_manufacture": null, "raw": ["017025", "000223", "0", "2013/Aug/29 14:35", "Firebird Boilers", "Rhino Savannah", "R20/26 Kitchen", "", "", "2012", "current", "4", "1", "1", "1", "0", "", "", "2", "2", "1", "20", "26", "", "", "89.2", "81.4", "", "59.5", "", "2", "", "", "201", "1", "1", "38", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "93.1", "96.9", "", "", "", "", "96.2"]} -{"pcdb_id": 17026, "brand_name": "Rhino Savannah", "model_name": "RC20/26 Combi Boiler", "model_qualifier": "", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 81.8, "comparative_hot_water_efficiency_pct": 57.5, "output_kw_max": 26.0, "final_year_of_manufacture": null, "raw": ["017026", "000223", "0", "2013/Aug/29 14:35", "Firebird Boilers", "Rhino Savannah", "RC20/26 Combi Boiler", "", "", "2012", "current", "4", "1", "1", "2", "0", "", "", "2", "2", "1", "20", "26", "", "", "89.2", "81.8", "", "57.5", "", "2", "", "", "202", "1", "1", "38", "0", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "93.1", "96.9", "", "", "", "", "96.2"]} -{"pcdb_id": 17027, "brand_name": "Rhino Savannah", "model_name": "RP20/26 Combipac", "model_qualifier": "", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 81.8, "comparative_hot_water_efficiency_pct": 57.5, "output_kw_max": 26.0, "final_year_of_manufacture": null, "raw": ["017027", "000223", "0", "2013/Aug/29 14:34", "Firebird Boilers", "Rhino Savannah", "RP20/26 Combipac", "", "", "2012", "current", "4", "1", "2", "2", "0", "", "", "2", "1", "1", "20", "26", "", "", "89.2", "81.8", "", "57.5", "", "2", "", "", "202", "1", "1", "38", "0", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "93.1", "96.9", "", "", "", "", "96.2"]} -{"pcdb_id": 17028, "brand_name": "Rhino Savannah", "model_name": "RH26/35 Heatpac", "model_qualifier": "", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 80.4, "comparative_hot_water_efficiency_pct": 58.7, "output_kw_max": 35.0, "final_year_of_manufacture": null, "raw": ["017028", "000223", "0", "2013/Aug/29 14:34", "Firebird Boilers", "Rhino Savannah", "RH26/35 Heatpac", "", "", "2012", "current", "4", "1", "2", "1", "0", "", "", "2", "1", "1", "26", "35", "", "", "88.2", "80.4", "", "58.7", "", "2", "", "", "201", "1", "1", "38", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "92.2", "94.6", "", "", "", "", "94.2"]} -{"pcdb_id": 17029, "brand_name": "Rhino Savannah", "model_name": "RB26/35 Boilerhouse", "model_qualifier": "", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 80.4, "comparative_hot_water_efficiency_pct": 58.7, "output_kw_max": 35.0, "final_year_of_manufacture": null, "raw": ["017029", "000223", "0", "2013/Aug/29 14:34", "Firebird Boilers", "Rhino Savannah", "RB26/35 Boilerhouse", "", "", "2012", "current", "4", "1", "1", "1", "0", "", "", "2", "2", "1", "26", "35", "", "", "88.2", "80.4", "", "58.7", "", "2", "", "", "201", "1", "1", "38", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "92.2", "94.6", "", "", "", "", "94.2"]} -{"pcdb_id": 17030, "brand_name": "Rhino Savannah", "model_name": "R26/35 Kitchen", "model_qualifier": "", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 80.4, "comparative_hot_water_efficiency_pct": 58.7, "output_kw_max": 35.0, "final_year_of_manufacture": null, "raw": ["017030", "000223", "0", "2013/Aug/29 14:34", "Firebird Boilers", "Rhino Savannah", "R26/35 Kitchen", "", "", "2012", "current", "4", "1", "1", "1", "0", "", "", "2", "2", "1", "26", "35", "", "", "88.2", "80.4", "", "58.7", "", "2", "", "", "201", "1", "1", "38", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "92.2", "94.6", "", "", "", "", "94.2"]} -{"pcdb_id": 17031, "brand_name": "Rhino Savannah", "model_name": "RC26/35 Combi Boiler", "model_qualifier": "", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 56.8, "output_kw_max": 35.0, "final_year_of_manufacture": null, "raw": ["017031", "000223", "0", "2013/Aug/29 14:34", "Firebird Boilers", "Rhino Savannah", "RC26/35 Combi Boiler", "", "", "2012", "current", "4", "1", "1", "2", "0", "", "", "2", "2", "1", "26", "35", "", "", "88.2", "80.8", "", "56.8", "", "2", "", "", "202", "1", "1", "38", "0", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "92.2", "94.6", "", "", "", "", "94.2"]} -{"pcdb_id": 17032, "brand_name": "Rhino Savannah", "model_name": "RP26/35 Combipac", "model_qualifier": "", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 56.8, "output_kw_max": 35.0, "final_year_of_manufacture": null, "raw": ["017032", "000223", "0", "2013/Aug/29 14:34", "Firebird Boilers", "Rhino Savannah", "RP26/35 Combipac", "", "", "2012", "current", "4", "1", "2", "2", "0", "", "", "2", "1", "1", "26", "35", "", "", "88.2", "80.8", "", "56.8", "", "2", "", "", "202", "1", "1", "38", "0", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "92.2", "94.6", "", "", "", "", "94.2"]} -{"pcdb_id": 17033, "brand_name": "Ideal", "model_name": "VOGUE", "model_qualifier": "s32", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 32.0, "final_year_of_manufacture": 2017, "raw": ["017033", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "VOGUE", "s32", "41-750-53", "2012", "2017", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "32", "32", "", "", "88.7", "79.7", "", "58.2", "", "2", "", "", "102", "1", "2", "117", "1", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "89.8", "97.8", "", "", "", "", "96.3"]} -{"pcdb_id": 17034, "brand_name": "Ideal", "model_name": "VOGUE", "model_qualifier": "s26", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 26.0, "final_year_of_manufacture": 2017, "raw": ["017034", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "VOGUE", "s26", "41-750-54", "2012", "2017", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "26", "26", "", "", "88.7", "79.7", "", "58.2", "", "2", "", "", "102", "1", "2", "102", "1", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "89.7", "97.8", "", "", "", "", "96.2"]} -{"pcdb_id": 17035, "brand_name": "Ideal", "model_name": "VOGUE", "model_qualifier": "s18", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 18.0, "final_year_of_manufacture": 2017, "raw": ["017035", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "VOGUE", "s18", "41-750-55", "2012", "2017", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18", "18", "", "", "88.7", "79.7", "", "58.2", "", "2", "", "", "102", "1", "2", "92", "1", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "89.8", "97.8", "", "", "", "", "96.3"]} -{"pcdb_id": 17036, "brand_name": "Ideal", "model_name": "VOGUE", "model_qualifier": "s15", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 15.0, "final_year_of_manufacture": 2017, "raw": ["017036", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "VOGUE", "s15", "41-750-56", "2012", "2017", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "15", "15", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "83", "1", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "89.6", "97.0", "", "", "", "", "95.6"]} -{"pcdb_id": 17037, "brand_name": "Ideal", "model_name": "VOGUE", "model_qualifier": "c26", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 76.4, "output_kw_max": 18.0, "final_year_of_manufacture": 2017, "raw": ["017037", "000008", "0", "2018/Oct/28 12:00", "Ideal Boilers", "Ideal", "VOGUE", "c26", "47-348-99", "2012", "2017", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "18", "18", "", "", "88.6", "87.3", "", "76.4", "", "2", "", "", "104", "1", "2", "108", "1", "0", "", "", "", "0", "", "", "", "", "1", "6.8963", "0.2267", "0.0286", "0.66626", "", "", "", "", "", "1", "1", "", "0035", "", "", "", "", "", "", "", "", "89.7", "97.7", "", "", "", "", "96.2"]} -{"pcdb_id": 17038, "brand_name": "Ideal", "model_name": "VOGUE", "model_qualifier": "c32", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 76.7, "output_kw_max": 26.0, "final_year_of_manufacture": 2017, "raw": ["017038", "000008", "0", "2018/Oct/28 12:00", "Ideal Boilers", "Ideal", "VOGUE", "c32", "47-348-98", "2012", "2017", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "26", "26", "", "", "88.7", "87.3", "", "76.7", "", "2", "", "", "104", "1", "2", "137", "1", "0", "", "", "", "0", "", "", "", "", "1", "6.8683", "0.1702", "0.0075", "0.76726", "", "", "", "", "", "1", "1", "", "0035", "", "", "", "", "", "", "", "", "89.9", "97.8", "", "", "", "", "96.3"]} -{"pcdb_id": 17039, "brand_name": "Ideal", "model_name": "VOGUE", "model_qualifier": "c40", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 76.8, "output_kw_max": 32.0, "final_year_of_manufacture": 2017, "raw": ["017039", "000008", "0", "2018/Oct/28 12:00", "Ideal Boilers", "Ideal", "VOGUE", "c40", "47-348-97", "2012", "2017", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "32", "32", "", "", "88.6", "87.3", "", "76.8", "", "2", "", "", "104", "1", "2", "133", "1", "0", "", "", "", "0", "", "", "", "", "1", "6.8578", "0.1994", "0.0292", "0.62576", "", "", "", "", "", "1", "1", "", "0035", "", "", "", "", "", "", "", "", "89.7", "97.5", "", "", "", "", "96.0"]} -{"pcdb_id": 17040, "brand_name": "Keston", "model_name": "Combi", "model_qualifier": "30", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 69.8, "output_kw_max": 24.2, "final_year_of_manufacture": null, "raw": ["017040", "000022", "0", "2013/Feb/27 12:37", "Keston Boilers", "Keston", "Combi", "30", "47-930-04", "2013", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "88.4", "87.3", "", "69.8", "", "2", "", "", "104", "1", "2", "1", "152", "0", "", "", "", "0", "", "", "", "", "1", "7.548", "0.1749", "0.0099", "1.41408", "", "", "", "", "", "1", "1", "", "0025", "", "", "", "", "", "", "", "", "90.0", "96.9", "", "", "", "", "95.6"]} -{"pcdb_id": 17041, "brand_name": "Keston", "model_name": "System", "model_qualifier": "30", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 30.3, "final_year_of_manufacture": null, "raw": ["017041", "000022", "0", "2013/Feb/27 12:38", "Keston Boilers", "Keston", "System", "30", "41-750-32", "2013", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "30.3", "30.3", "", "", "88.9", "79.9", "", "58.3", "", "2", "", "", "102", "1", "2", "1", "152", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "89.8", "98.2", "", "", "", "", "96.6"]} -{"pcdb_id": 17042, "brand_name": "Keston", "model_name": "Combi", "model_qualifier": "35", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 71.0, "output_kw_max": 24.2, "final_year_of_manufacture": null, "raw": ["017042", "000022", "0", "2013/Feb/27 12:38", "Keston Boilers", "Keston", "Combi", "35", "47-930-05", "2013", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "88.3", "87.3", "", "71.0", "", "2", "", "", "104", "1", "2", "1", "177", "0", "", "", "", "0", "", "", "", "", "1", "7.4216", "0.171", "0.0087", "1.2937", "", "", "", "", "", "1", "1", "", "0025", "", "", "", "", "", "", "", "", "89.8", "96.9", "", "", "", "", "95.5"]} -{"pcdb_id": 17043, "brand_name": "Ideal", "model_name": "LOGIC COMBI", "model_qualifier": "ES24", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 76.9, "output_kw_max": 24.2, "final_year_of_manufacture": 2016, "raw": ["017043", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "LOGIC COMBI", "ES24", "47-349-01", "2013", "2016", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "88.4", "87.3", "", "76.9", "", "2", "", "", "104", "1", "2", "146", "1", "0", "", "", "", "0", "", "", "", "", "1", "6.8467", "0.1294", "0.0257", "0.63741", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "", "", "", "", "89.8", "96.9", "", "", "", "", "95.6"]} -{"pcdb_id": 17044, "brand_name": "Ideal", "model_name": "LOGIC COMBI", "model_qualifier": "ES30", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 76.5, "output_kw_max": 24.2, "final_year_of_manufacture": 2016, "raw": ["017044", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "LOGIC COMBI", "ES30", "47-349-02", "2012", "2016", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "88.4", "87.3", "", "76.5", "", "2", "", "", "104", "1", "2", "152", "1", "0", "", "", "", "0", "", "", "", "", "1", "6.8814", "0.113", "0.0177", "0.72229", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "", "", "", "", "90.0", "96.9", "", "", "", "", "95.6"]} -{"pcdb_id": 17045, "brand_name": "Ideal", "model_name": "LOGIC COMBI", "model_qualifier": "ES35", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 76.0, "output_kw_max": 24.2, "final_year_of_manufacture": 2016, "raw": ["017045", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "LOGIC COMBI", "ES35", "47-349-03", "2013", "2016", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "88.3", "87.3", "", "76.0", "", "2", "", "", "104", "1", "2", "177", "1", "0", "", "", "", "0", "", "", "", "", "1", "6.9297", "0.1257", "0.0156", "0.77685", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "", "", "", "", "89.8", "96.9", "", "", "", "", "95.5"]} -{"pcdb_id": 17046, "brand_name": "Alpha", "model_name": "InTec 50 CS", "model_qualifier": "", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 81.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 28.0, "final_year_of_manufacture": null, "raw": ["017046", "000001", "0", "2024/Jan/31 10:17", "Alpha Therm", "Alpha", "InTec 50 CS", "", "", "2012", "current", "2", "1", "1", "2", "0", "", "", "2", "2", "2", "28", "28", "", "", "89.0", "81.7", "", "58.2", "", "2", "1", "", "106", "1", "2", "165", "4.4", "2", "", "", "54", "0", "50", "2", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.1", "98.8", "", "", "", "", "97.2"]} -{"pcdb_id": 17047, "brand_name": "Alpha", "model_name": "InTec 50 CS", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 86.7, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 28.0, "final_year_of_manufacture": null, "raw": ["017047", "000001", "0", "2019/Dec/16 13:35", "Alpha Therm", "Alpha", "InTec 50 CS", "", "", "2012", "current", "1", "1", "1", "2", "0", "", "", "2", "2", "2", "28", "28", "", "", "88.0", "86.7", "", "57.7", "", "2", "", "", "106", "1", "2", "165", "4.4", "2", "", "", "54", "0", "50", "2", "", "", "1", "9.123", "0.205", "0.0045", "2.91007", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.1", "96.7", "", "", "", "", "95.1"]} -{"pcdb_id": 17048, "brand_name": "Johnson & Starley", "model_name": "QuanTec", "model_qualifier": "16R", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 16.27, "final_year_of_manufacture": null, "raw": ["017048", "000239", "0", "2015/Sep/21 14:23", "Johnson & Starley", "Johnson & Starley", "QuanTec", "16R", "", "2013", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "16.27", "16.27", "", "", "89.0", "80.0", "", "58.4", "", "2", "", "", "102", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "", "", "", "", "88.7", "98.9", "", "", "", "", "97.0"]} -{"pcdb_id": 17049, "brand_name": "Johnson & Starley", "model_name": "QuanTec", "model_qualifier": "24R", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 23.4, "final_year_of_manufacture": null, "raw": ["017049", "000239", "0", "2015/Sep/21 14:23", "Johnson & Starley", "Johnson & Starley", "QuanTec", "24R", "", "2013", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "23.4", "23.4", "", "", "88.9", "79.9", "", "58.4", "", "2", "", "", "102", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "", "", "", "", "87.9", "99.1", "", "", "", "", "97.0"]} -{"pcdb_id": 17050, "brand_name": "Johnson & Starley", "model_name": "QuanTec", "model_qualifier": "24S", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 23.4, "final_year_of_manufacture": null, "raw": ["017050", "000239", "0", "2015/Sep/21 14:23", "Johnson & Starley", "Johnson & Starley", "QuanTec", "24S", "", "2013", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "23.4", "23.4", "", "", "88.9", "79.9", "", "58.4", "", "2", "", "", "102", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "", "", "", "", "87.9", "99.1", "", "", "", "", "97.0"]} -{"pcdb_id": 17051, "brand_name": "Johnson & Starley", "model_name": "QuanTec", "model_qualifier": "24C", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 86.9, "comparative_hot_water_efficiency_pct": 76.5, "output_kw_max": 16.27, "final_year_of_manufacture": null, "raw": ["017051", "000239", "0", "2015/Sep/21 14:23", "Johnson & Starley", "Johnson & Starley", "QuanTec", "24C", "CE595890", "2013", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "16.27", "16.27", "", "", "89.0", "86.9", "", "76.5", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "", "0", "", "", "", "", "1", "6.8876", "0.1134", "0.0145", "0.71547", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "", "", "", "", "88.7", "98.9", "", "", "", "", "97.0"]} -{"pcdb_id": 17052, "brand_name": "Johnson & Starley", "model_name": "QuanTec", "model_qualifier": "30C", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 86.7, "comparative_hot_water_efficiency_pct": 70.0, "output_kw_max": 23.4, "final_year_of_manufacture": null, "raw": ["017052", "000239", "0", "2015/Sep/21 14:23", "Johnson & Starley", "Johnson & Starley", "QuanTec", "30C", "", "2013", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "23.4", "23.4", "", "", "88.9", "86.7", "", "70.0", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "", "0", "", "", "", "", "1", "7.526", "0.1115", "0.0103", "1.33381", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "", "", "", "", "87.9", "99.1", "", "", "", "", "97.0"]} -{"pcdb_id": 17053, "brand_name": "Keston", "model_name": "Heat 55", "model_qualifier": "", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 52.1, "final_year_of_manufacture": null, "raw": ["017053", "000022", "0", "2013/May/24 12:33", "Keston Boilers", "Keston", "Heat 55", "", "41-930-41", "2013", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "52.1", "52.1", "", "", "88.9", "79.9", "", "58.4", "", "2", "", "", "102", "1", "2", "262", "8.91", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "89.7", "98.5", "", "", "", "", "96.8"]} -{"pcdb_id": 17054, "brand_name": "Keston", "model_name": "Heat 45", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 42.6, "final_year_of_manufacture": null, "raw": ["017054", "000022", "0", "2013/May/24 12:33", "Keston Boilers", "Keston", "Heat 45", "", "41-930-40", "2013", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "42.6", "42.6", "", "", "88.5", "79.5", "", "58.0", "", "2", "", "", "102", "1", "2", "202", "8.91", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "88.7", "97.7", "", "", "", "", "96.0"]} -{"pcdb_id": 17055, "brand_name": "Glow-worm", "model_name": "Ultimate 30c", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 86.5, "comparative_hot_water_efficiency_pct": 73.9, "output_kw_max": 24.2, "final_year_of_manufacture": null, "raw": ["017055", "000207", "0", "2013/Feb/28 09:24", "Vaillant Industrial UK", "Glow-worm", "Ultimate 30c", "", "GC No 47-019-20", "2013", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "88.3", "86.5", "", "73.9", "", "2", "", "", "104", "1", "2", "35", "3.5", "0", "", "", "", "0", "", "", "", "", "1", "7.125", "0.095", "0.0", "0.99665", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.5", "97.7", "", "", "", "", "95.7"]} -{"pcdb_id": 17056, "brand_name": "Glow-worm", "model_name": "Ultimate 30c", "model_qualifier": "", "winter_efficiency_pct": 89.3, "summer_efficiency_pct": 80.7, "comparative_hot_water_efficiency_pct": 56.7, "output_kw_max": 24.2, "final_year_of_manufacture": null, "raw": ["017056", "000207", "0", "2013/Feb/28 11:27", "Vaillant Industrial UK", "Glow-worm", "Ultimate 30c", "", "", "2013", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "89.3", "80.7", "", "56.7", "", "2", "1", "", "104", "1", "2", "35", "3.5", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.4", "99.8", "", "", "", "", "97.9"]} -{"pcdb_id": 17057, "brand_name": "Ferroli", "model_name": "Modena 32S HE", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 31.4, "final_year_of_manufacture": null, "raw": ["017057", "000097", "0", "2013/Jul/30 12:07", "Ferroli", "Ferroli", "Modena 32S HE", "", "", "2012", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "31.4", "31.4", "", "", "88.6", "79.6", "", "58.1", "", "2", "", "", "102", "1", "2", "100", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.4", "98.1", "", "", "", "", "96.3"]} -{"pcdb_id": 17058, "brand_name": "Glow-worm", "model_name": "Ultimate", "model_qualifier": "24h", "winter_efficiency_pct": 87.7, "summer_efficiency_pct": 78.7, "comparative_hot_water_efficiency_pct": 57.5, "output_kw_max": 24.0, "final_year_of_manufacture": null, "raw": ["017058", "000207", "0", "2013/Feb/28 09:23", "Glow-worm", "Glow-worm", "Ultimate", "24h", "GC 41-019-15", "2006", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24", "24", "", "", "87.7", "78.7", "", "57.5", "", "2", "", "", "102", "1", "2", "60", "6", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.8", "95.7", "", "", "", "", "94.4"]} -{"pcdb_id": 17059, "brand_name": "Grant", "model_name": "Vortex Pro Boilerhouse 36-46", "model_qualifier": "", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 46.0, "final_year_of_manufacture": null, "raw": ["017059", "000048", "0", "2014/Aug/15 12:54", "Grant Engineering (UK)", "Grant", "Vortex Pro Boilerhouse 36-46", "", "", "2012", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "36", "46", "", "", "87.9", "80.1", "", "58.5", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.8", "94.4", "", "", "", "", "93.8"]} -{"pcdb_id": 17060, "brand_name": "Grant", "model_name": "Vortex Pro Boilerhouse 46-58", "model_qualifier": "", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 81.1, "comparative_hot_water_efficiency_pct": 59.2, "output_kw_max": 58.0, "final_year_of_manufacture": null, "raw": ["017060", "000048", "0", "2013/Feb/27 15:44", "Grant Engineering (UK)", "Grant", "Vortex Pro Boilerhouse 46-58", "", "", "2012", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "46", "58", "", "", "88.9", "81.1", "", "59.2", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.5", "96.7", "", "", "", "", "95.7"]} -{"pcdb_id": 17061, "brand_name": "Grant", "model_name": "Vortex Pro Boilerhouse 58-70", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 59.0, "output_kw_max": 70.0, "final_year_of_manufacture": null, "raw": ["017061", "000048", "0", "2013/Feb/27 15:44", "Grant Engineering (UK)", "Grant", "Vortex Pro Boilerhouse 58-70", "", "", "2012", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "58", "70", "", "", "88.6", "80.8", "", "59.0", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.9", "96.2", "", "", "", "", "95.2"]} -{"pcdb_id": 17062, "brand_name": "Grant", "model_name": "Vortex Pro External 58-70", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 59.0, "output_kw_max": 70.0, "final_year_of_manufacture": null, "raw": ["017062", "000048", "0", "2014/Aug/15 12:57", "Grant Engineering (UK)", "Grant", "Vortex Pro External 58-70", "", "", "2012", "current", "4", "1", "2", "1", "0", "", "", "2", "3", "2", "58", "70", "", "", "88.6", "80.8", "", "59.0", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.9", "96.2", "", "", "", "", "95.2"]} -{"pcdb_id": 17063, "brand_name": "Grant", "model_name": "Vortex Pro External 46-58", "model_qualifier": "", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 81.1, "comparative_hot_water_efficiency_pct": 59.2, "output_kw_max": 58.0, "final_year_of_manufacture": null, "raw": ["017063", "000048", "0", "2013/Feb/27 15:44", "Grant Engineering (UK)", "Grant", "Vortex Pro External 46-58", "", "", "2012", "current", "4", "1", "2", "1", "0", "", "", "2", "3", "2", "46", "58", "", "", "88.9", "81.1", "", "59.2", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.5", "96.7", "", "", "", "", "95.7"]} -{"pcdb_id": 17064, "brand_name": "Sime", "model_name": "Meridian HE", "model_qualifier": "30", "winter_efficiency_pct": 89.3, "summer_efficiency_pct": 80.7, "comparative_hot_water_efficiency_pct": 56.7, "output_kw_max": 28.9, "final_year_of_manufacture": 2018, "raw": ["017064", "000213", "0", "2018/Mar/05 14:11", "Fonderie Sime S.p.A.", "Sime", "Meridian HE", "30", "", "2013", "2018", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "28.9", "28.9", "", "", "89.3", "80.7", "", "56.7", "", "2", "1", "", "104", "1", "2", "115", "4.9", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.3", "99.6", "", "", "", "", "97.8"]} -{"pcdb_id": 17066, "brand_name": "Sime", "model_name": "Meridian HE", "model_qualifier": "30", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 56.0, "output_kw_max": 28.9, "final_year_of_manufacture": 2018, "raw": ["017066", "000213", "0", "2018/Mar/05 14:12", "Fonderie Sime S.p.A.", "Sime", "Meridian HE", "30", "47-283-45", "2013", "2018", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28.9", "28.9", "", "", "88.3", "79.7", "", "56.0", "", "2", "", "", "104", "1", "2", "115", "4.9", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "97.4", "", "", "", "", "95.7"]} -{"pcdb_id": 17067, "brand_name": "Sime", "model_name": "Meridian HE", "model_qualifier": "25", "winter_efficiency_pct": 89.6, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 56.9, "output_kw_max": 23.9, "final_year_of_manufacture": 2018, "raw": ["017067", "000213", "0", "2018/Mar/05 14:10", "Fonderie Sime S.p.A.", "Sime", "Meridian HE", "25", "", "2013", "2018", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "23.9", "23.9", "", "", "89.6", "81.0", "", "56.9", "", "2", "1", "", "104", "1", "2", "105", "4.9", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.5", "100.1", "", "", "", "", "98.3"]} -{"pcdb_id": 17068, "brand_name": "Sime", "model_name": "Meridian HE", "model_qualifier": "25", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 56.2, "output_kw_max": 23.9, "final_year_of_manufacture": 2018, "raw": ["017068", "000213", "0", "2018/Mar/05 14:11", "Fonderie Sime S.p.A.", "Sime", "Meridian HE", "25", "47-283-44", "2013", "2018", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "23.9", "23.9", "", "", "88.5", "79.9", "", "56.2", "", "2", "", "", "104", "1", "2", "105", "4.9", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.6", "97.9", "", "", "", "", "96.2"]} -{"pcdb_id": 17069, "brand_name": "Baxi", "model_name": "Avanta 35c Exclusive", "model_qualifier": "", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 29.4, "final_year_of_manufacture": 2015, "raw": ["017069", "000005", "0", "2015/Aug/06 12:12", "Remeha", "Baxi", "Avanta 35c Exclusive", "", "47-288-05", "2012", "2015", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "29.4", "29.4", "", "", "88.9", "79.9", "", "58.4", "", "2", "", "", "102", "1", "2", "115", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.5", "98.8", "", "", "", "", "96.9"]} -{"pcdb_id": 17070, "brand_name": "Baxi", "model_name": "Avanta 39c Exclusive", "model_qualifier": "", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 33.3, "final_year_of_manufacture": 2015, "raw": ["017070", "000005", "0", "2015/Aug/06 12:12", "Remeha", "Baxi", "Avanta 39c Exclusive", "", "47-288-05", "2012", "2015", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "33.3", "33.3", "", "", "89.1", "80.1", "", "58.5", "", "2", "", "", "102", "1", "2", "180", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "99.6", "", "", "", "", "97.4"]} -{"pcdb_id": 17071, "brand_name": "Baxi", "model_name": "Avanta Plus 35c Combi", "model_qualifier": "", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 56.5, "output_kw_max": 29.4, "final_year_of_manufacture": 2015, "raw": ["017071", "000005", "0", "2015/Aug/06 12:13", "Remeha", "Baxi", "Avanta Plus 35c Combi", "", "47-673-03", "2005", "2015", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "29.4", "29.4", "", "", "88.9", "80.3", "", "56.5", "", "2", "", "", "104", "1", "2", "115", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.5", "98.8", "", "", "", "", "96.9"]} -{"pcdb_id": 17072, "brand_name": "Baxi", "model_name": "Avanta Plus 39c Combi", "model_qualifier": "", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 56.6, "output_kw_max": 33.3, "final_year_of_manufacture": 2015, "raw": ["017072", "000005", "0", "2015/Aug/06 12:13", "Remeha", "Baxi", "Avanta Plus 39c Combi", "", "47-673-04", "2005", "2015", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "33.3", "33.3", "", "", "89.1", "80.5", "", "56.6", "", "2", "", "", "104", "1", "2", "180", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "99.6", "", "", "", "", "97.4"]} -{"pcdb_id": 17073, "brand_name": "Baxi", "model_name": "Avanta Plus 28c Combi", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 56.2, "output_kw_max": 21.6, "final_year_of_manufacture": 2015, "raw": ["017073", "000005", "0", "2015/Aug/06 12:14", "Remeha", "Baxi", "Avanta Plus 28c Combi", "", "47-673-02", "2005", "2015", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "21.6", "21.6", "", "", "88.5", "79.9", "", "56.2", "", "2", "", "", "104", "1", "2", "115", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.6", "97.9", "", "", "", "", "96.2"]} -{"pcdb_id": 17074, "brand_name": "Baxi", "model_name": "Avanta 18 h Heat Only", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 17.6, "final_year_of_manufacture": 2015, "raw": ["017074", "000005", "0", "2015/Aug/06 12:14", "Remeha", "Baxi", "Avanta 18 h Heat Only", "", "41-288-06", "2006", "2015", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "17.6", "17.6", "", "", "88.5", "79.5", "", "58.1", "", "2", "", "", "102", "1", "2", "50", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.6", "97.9", "", "", "", "", "96.2"]} -{"pcdb_id": 17075, "brand_name": "Baxi", "model_name": "Avanta 30h Heat Only", "model_qualifier": "", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 29.4, "final_year_of_manufacture": 2015, "raw": ["017075", "000005", "0", "2015/Aug/06 12:15", "Remeha", "Baxi", "Avanta 30h Heat Only", "", "41-288-14", "2009", "2015", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "29.4", "29.4", "", "", "88.2", "79.2", "", "57.9", "", "2", "", "", "102", "1", "2", "115", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.5", "97.1", "", "", "", "", "95.5"]} -{"pcdb_id": 17076, "brand_name": "Baxi", "model_name": "Avanta Plus 30s system", "model_qualifier": "", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 29.4, "final_year_of_manufacture": 2015, "raw": ["017076", "000005", "0", "2015/Aug/06 12:15", "Remeha", "Baxi", "Avanta Plus 30s system", "", "41-288-12", "2008", "2015", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "29.4", "29.4", "", "", "88.2", "79.2", "", "57.9", "", "2", "", "", "102", "1", "2", "150", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.5", "97.1", "", "", "", "", "95.5"]} -{"pcdb_id": 17077, "brand_name": "Baxi", "model_name": "Avanta 28c Exclusive", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 21.6, "final_year_of_manufacture": 2015, "raw": ["017077", "000005", "0", "2015/Aug/06 12:16", "Remeha", "Baxi", "Avanta 28c Exclusive", "", "47-288-03", "2012", "2015", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "21.6", "21.6", "", "", "88.5", "79.5", "", "58.1", "", "2", "", "", "102", "1", "2", "115", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.6", "97.9", "", "", "", "", "96.2"]} -{"pcdb_id": 17078, "brand_name": "Baxi", "model_name": "Avanta 15h Heat Only", "model_qualifier": "", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 15.0, "final_year_of_manufacture": 2015, "raw": ["017078", "000005", "0", "2015/Aug/06 12:17", "Remeha", "Baxi", "Avanta 15h Heat Only", "", "41-288-13", "2012", "2015", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "15", "15", "", "", "88.2", "79.2", "", "57.8", "", "2", "", "", "102", "1", "2", "50", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.4", "97.0", "", "", "", "", "95.4"]} -{"pcdb_id": 17079, "brand_name": "Baxi", "model_name": "Avanta Plus 24c Combi", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 55.9, "output_kw_max": 20.0, "final_year_of_manufacture": 2015, "raw": ["017079", "000005", "0", "2015/Aug/06 12:17", "Remeha", "Baxi", "Avanta Plus 24c Combi", "", "47-288-01", "2008", "2015", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "20", "20", "", "", "88.1", "79.5", "", "55.9", "", "2", "", "", "104", "1", "2", "115", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.1", "97.0", "", "", "", "", "95.3"]} -{"pcdb_id": 17080, "brand_name": "Baxi", "model_name": "Avanta Plus 18s system", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 17.6, "final_year_of_manufacture": 2015, "raw": ["017080", "000005", "0", "2015/Aug/06 12:19", "Remeha", "Baxi", "Avanta Plus 18s system", "", "41-288-11", "2008", "2015", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "17.6", "17.6", "", "", "88.1", "79.1", "", "57.8", "", "2", "", "", "102", "1", "2", "115", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.1", "97.0", "", "", "", "", "95.3"]} -{"pcdb_id": 17081, "brand_name": "Baxi", "model_name": "Avanta Plus 24s System", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 21.6, "final_year_of_manufacture": 2015, "raw": ["017081", "000005", "0", "2015/Aug/06 12:20", "Remeha", "Baxi", "Avanta Plus 24s System", "", "41-288-05", "2005", "2015", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "21.6", "21.6", "", "", "88.5", "79.5", "", "58.1", "", "2", "", "", "102", "1", "2", "115", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.6", "97.9", "", "", "", "", "96.2"]} -{"pcdb_id": 17082, "brand_name": "Baxi", "model_name": "Avanta 24h Heat Only", "model_qualifier": "", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 24.7, "final_year_of_manufacture": 2015, "raw": ["017082", "000005", "0", "2015/Aug/06 12:21", "Remeha", "Baxi", "Avanta 24h Heat Only", "", "41-288-10", "2008", "2015", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "24.7", "24.7", "", "", "88.2", "79.2", "", "57.8", "", "2", "", "", "102", "1", "2", "50", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.2", "97.1", "", "", "", "", "95.4"]} -{"pcdb_id": 17083, "brand_name": "Glow-worm", "model_name": "Ultimate", "model_qualifier": "35c", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 86.6, "comparative_hot_water_efficiency_pct": 73.4, "output_kw_max": 30.0, "final_year_of_manufacture": null, "raw": ["017083", "000207", "0", "2013/Apr/22 17:06", "Glow-worm", "Glow-worm", "Ultimate", "35c", "47-019-21", "2013", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "8.5", "30", "", "", "88.2", "86.6", "", "73.4", "", "2", "", "", "104", "1", "2", "41", "3.5", "0", "", "", "", "0", "", "", "", "", "1", "7.17", "0.114", "0.0", "1.04455", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.7", "97.4", "", "", "", "", "95.5"]} -{"pcdb_id": 17084, "brand_name": "Glow-worm", "model_name": "Ultimate", "model_qualifier": "35c", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 80.6, "comparative_hot_water_efficiency_pct": 56.7, "output_kw_max": 30.0, "final_year_of_manufacture": null, "raw": ["017084", "000207", "0", "2013/Apr/22 17:06", "Glow-worm", "Glow-worm", "Ultimate", "35c", "", "2013", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "8.5", "30", "", "", "89.2", "80.6", "", "56.7", "", "2", "1", "", "104", "1", "2", "41", "3.5", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.6", "99.6", "", "", "", "", "97.7"]} -{"pcdb_id": 17085, "brand_name": "Baxi", "model_name": "Avanta 35c Exclusive", "model_qualifier": "", "winter_efficiency_pct": 89.9, "summer_efficiency_pct": 80.9, "comparative_hot_water_efficiency_pct": 59.1, "output_kw_max": 29.4, "final_year_of_manufacture": null, "raw": ["017085", "000005", "0", "2013/Apr/15 09:06", "Remeha", "Baxi", "Avanta 35c Exclusive", "", "", "2012", "current", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "29.4", "29.4", "", "", "89.9", "80.9", "", "59.1", "", "2", "1", "", "102", "1", "2", "115", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.4", "101.0", "", "", "", "", "99.0"]} -{"pcdb_id": 17086, "brand_name": "Baxi", "model_name": "Avanta 39c Exclusive", "model_qualifier": "", "winter_efficiency_pct": 90.2, "summer_efficiency_pct": 81.2, "comparative_hot_water_efficiency_pct": 59.3, "output_kw_max": 33.3, "final_year_of_manufacture": null, "raw": ["017086", "000005", "0", "2013/Apr/15 09:05", "Remeha", "Baxi", "Avanta 39c Exclusive", "", "", "2012", "current", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "33.3", "33.3", "", "", "90.2", "81.2", "", "59.3", "", "2", "1", "", "102", "1", "2", "180", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.3", "101.8", "", "", "", "", "99.6"]} -{"pcdb_id": 17087, "brand_name": "Baxi", "model_name": "Avanta Plus 35c Combi", "model_qualifier": "", "winter_efficiency_pct": 89.9, "summer_efficiency_pct": 81.3, "comparative_hot_water_efficiency_pct": 57.2, "output_kw_max": 29.4, "final_year_of_manufacture": null, "raw": ["017087", "000005", "0", "2013/May/13 09:31", "Remeha", "Baxi", "Avanta Plus 35c Combi", "", "", "2005", "current", "2", "2", "1", "2", "0", "", "", "2", "3", "2", "29.4", "29.4", "", "", "89.9", "81.3", "", "57.2", "", "2", "1", "", "104", "1", "2", "115", "3", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.4", "101.0", "", "", "", "", "99.0"]} -{"pcdb_id": 17088, "brand_name": "Baxi", "model_name": "Avanta Plus 39c Combi", "model_qualifier": "", "winter_efficiency_pct": 90.2, "summer_efficiency_pct": 81.6, "comparative_hot_water_efficiency_pct": 57.4, "output_kw_max": 33.3, "final_year_of_manufacture": null, "raw": ["017088", "000005", "0", "2013/Apr/15 09:05", "Remeha", "Baxi", "Avanta Plus 39c Combi", "", "", "2005", "current", "2", "2", "1", "2", "0", "", "", "2", "3", "2", "33.3", "33.3", "", "", "90.2", "81.6", "", "57.4", "", "2", "1", "", "104", "1", "2", "180", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.3", "101.8", "", "", "", "", "99.6"]} -{"pcdb_id": 17089, "brand_name": "Baxi", "model_name": "Avanta Plus 28c Combi", "model_qualifier": "", "winter_efficiency_pct": 89.6, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 56.9, "output_kw_max": 21.6, "final_year_of_manufacture": null, "raw": ["017089", "000005", "0", "2013/Apr/15 09:04", "Remeha", "Baxi", "Avanta Plus 28c Combi", "", "", "2005", "current", "2", "2", "1", "2", "0", "", "", "2", "3", "2", "21.6", "21.6", "", "", "89.6", "81.0", "", "56.9", "", "2", "1", "", "104", "1", "2", "115", "3", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.5", "100.1", "", "", "", "", "98.3"]} -{"pcdb_id": 17090, "brand_name": "Baxi", "model_name": "Avanta 18h Heat Only", "model_qualifier": "", "winter_efficiency_pct": 89.6, "summer_efficiency_pct": 80.6, "comparative_hot_water_efficiency_pct": 58.8, "output_kw_max": 17.6, "final_year_of_manufacture": null, "raw": ["017090", "000005", "0", "2013/Apr/15 09:04", "Remeha", "Baxi", "Avanta 18h Heat Only", "", "", "2006", "current", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "17.6", "17.6", "", "", "89.6", "80.6", "", "58.8", "", "2", "1", "", "102", "1", "2", "50", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.5", "100.1", "", "", "", "", "98.3"]} -{"pcdb_id": 17091, "brand_name": "Baxi", "model_name": "Avanta 30h Heat Only", "model_qualifier": "", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 29.4, "final_year_of_manufacture": null, "raw": ["017091", "000005", "0", "2013/Apr/15 09:01", "Remeha", "Baxi", "Avanta 30h Heat Only", "", "", "2006", "current", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "29.4", "29.4", "", "", "89.2", "80.2", "", "58.6", "", "2", "1", "", "102", "1", "2", "115", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.4", "99.3", "", "", "", "", "97.6"]} -{"pcdb_id": 17092, "brand_name": "Baxi", "model_name": "Avanta Plus 30s System", "model_qualifier": "", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 29.4, "final_year_of_manufacture": null, "raw": ["017092", "000005", "0", "2013/Apr/15 09:00", "Remeha", "Baxi", "Avanta Plus 30s System", "", "", "2008", "current", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "29.4", "29.4", "", "", "89.2", "80.2", "", "58.6", "", "2", "1", "", "102", "1", "2", "150", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.5", "99.3", "", "", "", "", "97.6"]} -{"pcdb_id": 17093, "brand_name": "Baxi", "model_name": "Avanta 28c Exclusive", "model_qualifier": "", "winter_efficiency_pct": 89.6, "summer_efficiency_pct": 80.6, "comparative_hot_water_efficiency_pct": 58.8, "output_kw_max": 21.6, "final_year_of_manufacture": null, "raw": ["017093", "000005", "0", "2013/Apr/15 08:59", "Remeha", "Baxi", "Avanta 28c Exclusive", "", "", "2012", "current", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "21.6", "21.6", "", "", "89.6", "80.6", "", "58.8", "", "2", "1", "", "102", "1", "2", "115", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.5", "100.1", "", "", "", "", "98.3"]} -{"pcdb_id": 17094, "brand_name": "Baxi", "model_name": "Avanta 15h Heat Only", "model_qualifier": "", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 15.0, "final_year_of_manufacture": null, "raw": ["017094", "000005", "0", "2013/Apr/15 08:57", "Remeha", "Baxi", "Avanta 15h Heat Only", "", "", "2012", "current", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "15", "15", "", "", "89.2", "80.2", "", "58.6", "", "2", "1", "", "102", "1", "2", "50", "33", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.4", "99.2", "", "", "", "", "97.5"]} -{"pcdb_id": 17095, "brand_name": "Baxi", "model_name": "Avanta Plus 24c Combi", "model_qualifier": "", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 56.6, "output_kw_max": 20.0, "final_year_of_manufacture": null, "raw": ["017095", "000005", "0", "2013/Apr/15 08:56", "Remeha", "Baxi", "Avanta Plus 24c Combi", "", "", "2008", "current", "2", "2", "1", "2", "0", "", "", "2", "3", "2", "20", "20", "", "", "89.1", "80.5", "", "56.6", "", "2", "1", "", "104", "1", "2", "115", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.1", "99.2", "", "", "", "", "97.5"]} -{"pcdb_id": 17096, "brand_name": "Baxi", "model_name": "Avanta Plus 18s System", "model_qualifier": "", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 17.6, "final_year_of_manufacture": null, "raw": ["017096", "000005", "0", "2013/May/13 09:21", "Remeha", "Baxi", "Avanta Plus 18s System", "", "", "2008", "current", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "17.6", "17.6", "", "", "89.1", "80.1", "", "58.5", "", "2", "1", "", "102", "1", "2", "115", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.1", "99.2", "", "", "", "", "97.5"]} -{"pcdb_id": 17097, "brand_name": "Baxi", "model_name": "Avanta Plus 24s System", "model_qualifier": "", "winter_efficiency_pct": 89.6, "summer_efficiency_pct": 80.6, "comparative_hot_water_efficiency_pct": 58.8, "output_kw_max": 21.6, "final_year_of_manufacture": null, "raw": ["017097", "000005", "0", "2013/Apr/15 08:55", "Remeha", "Baxi", "Avanta Plus 24s System", "", "", "2005", "current", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "21.6", "21.6", "", "", "89.6", "80.6", "", "58.8", "", "2", "1", "", "102", "1", "2", "115", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.5", "100.1", "", "", "", "", "98.3"]} -{"pcdb_id": 17098, "brand_name": "Baxi", "model_name": "Avanta 24h Heat Only", "model_qualifier": "", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 24.7, "final_year_of_manufacture": null, "raw": ["017098", "000005", "0", "2013/Apr/15 09:20", "Remeha", "Baxi", "Avanta 24h Heat Only", "", "", "2008", "current", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "24.7", "24.7", "", "", "89.2", "80.2", "", "58.6", "", "2", "1", "", "102", "1", "2", "50", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.2", "99.3", "", "", "", "", "97.6"]} -{"pcdb_id": 17099, "brand_name": "Main", "model_name": "Combi Eco Classic", "model_qualifier": "30", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 55.9, "output_kw_max": 28.63, "final_year_of_manufacture": 2015, "raw": ["017099", "000005", "0", "2015/Aug/06 13:17", "Baxi Heating UK", "Main", "Combi Eco Classic", "30", "GC 47-467-11", "2013", "2015", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28.63", "28.63", "", "", "88.1", "79.5", "", "55.9", "", "2", "", "", "104", "1", "2", "150", "3.5", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "97.0", "", "", "", "", "95.3"]} -{"pcdb_id": 17100, "brand_name": "Main", "model_name": "Combi Eco Classic", "model_qualifier": "24", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 56.1, "output_kw_max": 25.94, "final_year_of_manufacture": 2015, "raw": ["017100", "000005", "0", "2015/Aug/06 13:17", "Baxi Heating UK", "Main", "Combi Eco Classic", "24", "GC No. 47-467-10", "2013", "2015", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "25.94", "25.94", "", "", "88.4", "79.8", "", "56.1", "", "2", "", "", "104", "1", "2", "150", "3.5", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.7", "97.0", "", "", "", "", "95.7"]} -{"pcdb_id": 17103, "brand_name": "Worcester", "model_name": "Greenstar Danesmoor External", "model_qualifier": "12/18", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 58.8, "output_kw_max": 18.0, "final_year_of_manufacture": 2015, "raw": ["017103", "000035", "0", "2020/Sep/08 10:38", "Worcester Bosch Group", "Worcester", "Greenstar Danesmoor External", "12/18", "", "2013", "2015", "4", "1", "2", "1", "0", "", "", "2", "2", "1", "12", "18", "", "", "88.3", "80.5", "", "58.8", "", "2", "", "", "201", "1", "1", "145", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.1", "95.4", "", "", "", "", "94.6"]} -{"pcdb_id": 17104, "brand_name": "Worcester", "model_name": "Greenstar Danesmoor", "model_qualifier": "12/18", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 58.8, "output_kw_max": 18.0, "final_year_of_manufacture": 2015, "raw": ["017104", "000035", "0", "2020/Sep/08 10:38", "Worcester Bosch Group", "Worcester", "Greenstar Danesmoor", "12/18", "", "2013", "2015", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "12", "18", "", "", "88.3", "80.5", "", "58.8", "", "2", "", "", "201", "1", "1", "145", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.1", "95.4", "", "", "", "", "94.6"]} -{"pcdb_id": 17105, "brand_name": "Worcester", "model_name": "Greenstar Danesmoor Utility", "model_qualifier": "12/18", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 58.8, "output_kw_max": 18.0, "final_year_of_manufacture": 2015, "raw": ["017105", "000035", "0", "2020/Sep/08 10:38", "Worcester Bosch Group", "Worcester", "Greenstar Danesmoor Utility", "12/18", "", "2013", "2015", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "12", "18", "", "", "88.3", "80.5", "", "58.8", "", "2", "", "", "201", "1", "1", "145", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.1", "95.4", "", "", "", "", "94.6"]} -{"pcdb_id": 17106, "brand_name": "Worcester", "model_name": "Greenstar Danesmoor External", "model_qualifier": "18/25", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 58.7, "output_kw_max": 25.0, "final_year_of_manufacture": 2015, "raw": ["017106", "000035", "0", "2020/Sep/08 10:39", "Worcester Bosch Group", "Worcester", "Greenstar Danesmoor External", "18/25", "", "2013", "2015", "4", "1", "2", "1", "0", "", "", "2", "2", "1", "18", "25", "", "", "88.1", "80.3", "", "58.7", "", "2", "", "", "201", "1", "1", "145", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.9", "95.1", "", "", "", "", "94.3"]} -{"pcdb_id": 17107, "brand_name": "Worcester", "model_name": "Greenstar Danesmoor", "model_qualifier": "18/25", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 58.7, "output_kw_max": 25.0, "final_year_of_manufacture": 2015, "raw": ["017107", "000035", "0", "2020/Sep/08 10:39", "Worcester Bosch Group", "Worcester", "Greenstar Danesmoor", "18/25", "", "2013", "2015", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "18", "25", "", "", "88.1", "80.3", "", "58.7", "", "2", "", "", "201", "1", "1", "145", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.9", "95.1", "", "", "", "", "94.3"]} -{"pcdb_id": 17108, "brand_name": "Worcester", "model_name": "Greenstar Danesmoor Utility", "model_qualifier": "18/25", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 58.7, "output_kw_max": 25.0, "final_year_of_manufacture": 2015, "raw": ["017108", "000035", "0", "2020/Sep/08 10:39", "Worcester Bosch Group", "Worcester", "Greenstar Danesmoor Utility", "18/25", "", "2013", "2015", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "18", "25", "", "", "88.1", "80.3", "", "58.7", "", "2", "", "", "201", "1", "1", "145", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.9", "95.1", "", "", "", "", "94.3"]} -{"pcdb_id": 17109, "brand_name": "Worcester", "model_name": "Greenstar Danesmoor External", "model_qualifier": "25/32", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 32.0, "final_year_of_manufacture": 2015, "raw": ["017109", "000035", "0", "2020/Sep/08 10:39", "Worcester Bosch Group", "Worcester", "Greenstar Danesmoor External", "25/32", "", "2013", "2015", "4", "1", "2", "1", "0", "", "", "2", "2", "1", "25", "32", "", "", "87.9", "80.1", "", "58.5", "", "2", "", "", "201", "1", "1", "150", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.4", "94.3", "", "", "", "", "93.7"]} -{"pcdb_id": 17110, "brand_name": "Worcester", "model_name": "Greenstar Danesmoor", "model_qualifier": "25/32", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 32.0, "final_year_of_manufacture": 2015, "raw": ["017110", "000035", "0", "2020/Sep/08 10:39", "Worcester Bosch Group", "Worcester", "Greenstar Danesmoor", "25/32", "", "2013", "2015", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "25", "32", "", "", "87.9", "80.1", "", "58.5", "", "2", "", "", "201", "1", "1", "150", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.4", "94.3", "", "", "", "", "93.7"]} -{"pcdb_id": 17111, "brand_name": "Worcester", "model_name": "Greenstar Danesmoor Utility", "model_qualifier": "25/32", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 32.0, "final_year_of_manufacture": 2015, "raw": ["017111", "000035", "0", "2020/Sep/08 10:40", "Worcester Bosch Group", "Worcester", "Greenstar Danesmoor Utility", "25/32", "", "2013", "2015", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "25", "32", "", "", "87.9", "80.1", "", "58.5", "", "2", "", "", "201", "1", "1", "150", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.4", "94.3", "", "", "", "", "93.7"]} -{"pcdb_id": 17113, "brand_name": "Vokera", "model_name": "Unica", "model_qualifier": "I28", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 86.9, "comparative_hot_water_efficiency_pct": 73.4, "output_kw_max": 19.62, "final_year_of_manufacture": null, "raw": ["017113", "000011", "0", "2015/Jan/19 11:04", "Vokera", "Vokera", "Unica", "I28", "4709412", "2013", "current", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "19.62", "19.62", "", "", "89.0", "86.9", "", "73.4", "", "2", "", "", "104", "1", "2", "120", "4.9", "0", "", "", "", "0", "", "", "", "", "1", "7.178", "0.122", "0.0095", "1.02018", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "", "", "", "", "88.6", "99.0", "", "", "", "", "97.0"]} -{"pcdb_id": 17114, "brand_name": "Vokera", "model_name": "Unica", "model_qualifier": "I32", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 86.9, "comparative_hot_water_efficiency_pct": 72.2, "output_kw_max": 24.58, "final_year_of_manufacture": null, "raw": ["017114", "000011", "0", "2016/Sep/21 11:28", "Vokera", "Vokera", "Unica", "I32", "4736415", "2013", "current", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "24.58", "24.58", "", "", "89.0", "86.9", "", "72.2", "", "2", "", "", "104", "1", "2", "126", "4.9", "0", "", "", "", "0", "", "", "", "", "1", "7.292", "0.14", "0.0055", "1.15348", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "", "", "", "", "88.6", "99.0", "", "", "", "", "97.0"]} -{"pcdb_id": 17115, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "30 Si Compact", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 87.1, "comparative_hot_water_efficiency_pct": 75.0, "output_kw_max": 24.0, "final_year_of_manufacture": 2015, "raw": ["017115", "000035", "0", "2020/Apr/09 16:38", "Worcester Bosch Group", "Worcester", "Greenstar", "30 Si Compact", "47-406-52", "2013", "2015", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "89.2", "87.1", "", "75.0", "", "2", "", "", "104", "1", "2", "114", "1.0", "0", "", "", "", "0", "", "", "", "", "2", "7.02", "0.076", "0.001", "0.92442", "13.03", "0.098", "0.0005", "0.7998", "0.00001", "1", "1", "", "0305", "", "", "", "", "", "", "", "", "88.8", "99.6", "", "", "", "", "97.5"]} -{"pcdb_id": 17116, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "30 Si Compact", "winter_efficiency_pct": 90.3, "summer_efficiency_pct": 90.3, "comparative_hot_water_efficiency_pct": 75.2, "output_kw_max": 24.0, "final_year_of_manufacture": 2015, "raw": ["017116", "000035", "0", "2020/Apr/09 16:37", "Worcester Bosch Group", "Worcester", "Greenstar", "30 Si Compact", "47-406-53", "2013", "2015", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "90.3", "90.3", "", "75.2", "", "2", "1", "", "104", "1", "2", "114", "1.0", "0", "", "", "", "0", "", "", "", "", "2", "7.16", "0.089", "0.0014", "1.05749", "12.99", "0.105", "0.0015", "1.02677", "0.0", "1", "1", "", "0305", "", "", "", "", "", "", "", "", "90.8", "101.8", "", "", "", "", "99.7"]} -{"pcdb_id": 17117, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "25 Si Compact", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 88.2, "comparative_hot_water_efficiency_pct": 74.6, "output_kw_max": 24.0, "final_year_of_manufacture": 2015, "raw": ["017117", "000035", "0", "2020/Apr/09 16:37", "Worcester Bosch Group", "Worcester", "Greenstar", "25 Si Compact", "47-406-50", "2013", "2015", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "89.2", "88.2", "", "74.6", "", "2", "", "", "104", "1", "2", "104", "1.0", "0", "", "", "", "0", "", "", "", "", "2", "7.06", "0.091", "0.0013", "0.96127", "12.8", "0.114", "0.0007", "0.9203", "0.00001", "1", "1", "", "0305", "", "", "", "", "", "", "", "", "88.8", "99.6", "", "", "", "", "97.5"]} -{"pcdb_id": 17118, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "25 Si Compact", "winter_efficiency_pct": 90.3, "summer_efficiency_pct": 90.3, "comparative_hot_water_efficiency_pct": 75.8, "output_kw_max": 24.0, "final_year_of_manufacture": 2015, "raw": ["017118", "000035", "0", "2020/Apr/09 16:36", "Worcester Bosch Group", "Worcester", "Greenstar", "25 Si Compact", "47-406-51", "2013", "2015", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "90.3", "90.3", "", "75.8", "", "2", "1", "", "104", "1", "2", "104", "1.0", "0", "", "", "", "0", "", "", "", "", "2", "7.1", "0.09", "0.0014", "0.99958", "12.83", "0.111", "0.0007", "0.96912", "0.00001", "1", "1", "", "0305", "", "", "", "", "", "", "", "", "90.8", "101.8", "", "", "", "", "99.7"]} -{"pcdb_id": 17119, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "30 Ri Compact", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 30.0, "final_year_of_manufacture": 2015, "raw": ["017119", "000035", "0", "2020/Sep/08 10:40", "Worcester Bosch Group", "Worcester", "Greenstar", "30 Ri Compact", "47-406-19", "2013", "2015", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "30", "30", "", "", "88.3", "79.3", "", "57.9", "", "2", "", "", "102", "1", "2", "41.0", "1.0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0305", "", "", "", "", "", "", "", "", "88.2", "97.4", "", "", "", "", "95.7"]} -{"pcdb_id": 17120, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "30 Ri Compact", "winter_efficiency_pct": 89.3, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 30.0, "final_year_of_manufacture": 2015, "raw": ["017120", "000035", "0", "2020/Sep/08 10:40", "Worcester Bosch Group", "Worcester", "Greenstar", "30 Ri Compact", "47-406-20", "2013", "2015", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "30", "30", "", "", "89.3", "80.3", "", "58.6", "", "2", "1", "", "102", "1", "2", "41.0", "1.0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0305", "", "", "", "", "", "", "", "", "90.2", "99.6", "", "", "", "", "97.8"]} -{"pcdb_id": 17121, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "27 Ri Compact", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 27.0, "final_year_of_manufacture": 2015, "raw": ["017121", "000035", "0", "2020/Sep/08 10:40", "Worcester Bosch Group", "Worcester", "Greenstar", "27 Ri Compact", "47-406-17", "2013", "2015", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "27", "27", "", "", "88.3", "79.3", "", "57.9", "", "2", "", "", "102", "1", "2", "35", "1.0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0305", "", "", "", "", "", "", "", "", "88.2", "97.4", "", "", "", "", "95.7"]} -{"pcdb_id": 17122, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "27 Ri Compact", "winter_efficiency_pct": 89.3, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 27.0, "final_year_of_manufacture": 2015, "raw": ["017122", "000035", "0", "2020/Sep/08 10:40", "Worcester Bosch Group", "Worcester", "Greenstar", "27 Ri Compact", "47-406-18", "2013", "2015", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "27", "27", "", "", "89.3", "80.3", "", "58.6", "", "2", "1", "", "102", "1", "2", "35", "1.0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0305", "", "", "", "", "", "", "", "", "90.2", "99.6", "", "", "", "", "97.8"]} -{"pcdb_id": 17123, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "27 I System Compact", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 27.0, "final_year_of_manufacture": 2015, "raw": ["017123", "000035", "0", "2020/Sep/08 10:40", "Worcester Bosch Group", "Worcester", "Greenstar", "27 I System Compact", "47-406-13", "2013", "2015", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "27", "27", "", "", "88.3", "79.3", "", "57.9", "", "2", "", "", "102", "1", "2", "102", "1.0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0305", "", "", "", "", "", "", "", "", "88.2", "97.4", "", "", "", "", "95.7"]} -{"pcdb_id": 17124, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "27 I System Compact", "winter_efficiency_pct": 89.3, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 27.0, "final_year_of_manufacture": 2015, "raw": ["017124", "000035", "0", "2020/Sep/08 10:40", "Worcester Bosch Group", "Worcester", "Greenstar", "27 I System Compact", "47-406-14", "2013", "2015", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "27", "27", "", "", "89.3", "80.3", "", "58.6", "", "2", "1", "", "102", "1", "2", "102", "1.0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0305", "", "", "", "", "", "", "", "", "90.2", "99.6", "", "", "", "", "97.8"]} -{"pcdb_id": 17125, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "30 I System Compact", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 30.0, "final_year_of_manufacture": 2015, "raw": ["017125", "000035", "0", "2020/Sep/08 10:40", "Worcester Bosch Group", "Worcester", "Greenstar", "30 I System Compact", "47-406-15", "2013", "2015", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "30", "30", "", "", "88.3", "79.3", "", "57.9", "", "2", "", "", "102", "1", "2", "108", "1.0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0305", "", "", "", "", "", "", "", "", "88.2", "97.4", "", "", "", "", "95.7"]} -{"pcdb_id": 17126, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "30 I System Compact", "winter_efficiency_pct": 89.3, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 30.0, "final_year_of_manufacture": 2015, "raw": ["017126", "000035", "0", "2020/Sep/08 10:40", "Worcester Bosch Group", "Worcester", "Greenstar", "30 I System Compact", "47-406-16", "2013", "2015", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "30", "30", "", "", "89.3", "80.3", "", "58.6", "", "2", "1", "", "102", "1", "2", "108", "1.0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0305", "", "", "", "", "", "", "", "", "90.2", "99.6", "", "", "", "", "97.8"]} -{"pcdb_id": 17127, "brand_name": "Ferroli", "model_name": "Modena 18S HE", "model_qualifier": "", "winter_efficiency_pct": 89.6, "summer_efficiency_pct": 80.6, "comparative_hot_water_efficiency_pct": 58.9, "output_kw_max": 17.4, "final_year_of_manufacture": null, "raw": ["017127", "000097", "0", "2013/Jun/25 12:56", "Ferroli", "Ferroli", "Modena 18S HE", "", "", "2012", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "17.4", "17.4", "", "", "89.6", "80.6", "", "58.9", "", "2", "1", "", "102", "1", "2", "100", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.3", "100.3", "", "", "", "", "98.4"]} -{"pcdb_id": 17128, "brand_name": "A O Smith", "model_name": "UB70 G", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 60.1, "final_year_of_manufacture": null, "raw": ["017128", "000275", "0", "2013/Jun/26 07:55", "ATAG Verwarming Nederland BV", "A O Smith", "UB70 G", "", "", "2011", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "60.1", "60.1", "", "", "88.8", "79.8", "", "58.3", "", "2", "", "", "102", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.7", "98.9", "", "", "", "", "96.8"]} -{"pcdb_id": 17130, "brand_name": "Ferroli", "model_name": "Modena 27C HE", "model_qualifier": "", "winter_efficiency_pct": 89.6, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 56.9, "output_kw_max": 24.5, "final_year_of_manufacture": null, "raw": ["017130", "000097", "0", "2013/Jun/27 16:52", "Ferroli", "Ferroli", "Modena 27C HE", "", "", "2012", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24.5", "24.5", "", "", "89.6", "81.0", "", "56.9", "", "2", "1", "", "104", "1", "2", "100", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.4", "100.2", "", "", "", "", "98.3"]} -{"pcdb_id": 17131, "brand_name": "Ferroli", "model_name": "Modena 32S HE", "model_qualifier": "", "winter_efficiency_pct": 89.6, "summer_efficiency_pct": 80.6, "comparative_hot_water_efficiency_pct": 58.9, "output_kw_max": 31.4, "final_year_of_manufacture": null, "raw": ["017131", "000097", "0", "2013/Jun/27 16:53", "Ferroli", "Ferroli", "Modena 32S HE", "", "", "2012", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "31.4", "31.4", "", "", "89.6", "80.6", "", "58.9", "", "2", "1", "", "102", "1", "2", "100", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.4", "100.3", "", "", "", "", "98.4"]} -{"pcdb_id": 17132, "brand_name": "Ferroli", "model_name": "Modena 25S HE", "model_qualifier": "", "winter_efficiency_pct": 89.6, "summer_efficiency_pct": 80.6, "comparative_hot_water_efficiency_pct": 58.9, "output_kw_max": 24.55, "final_year_of_manufacture": null, "raw": ["017132", "000097", "0", "2013/Jun/27 16:53", "Ferroli", "Ferroli", "Modena 25S HE", "", "", "2012", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "24.55", "24.55", "", "", "89.6", "80.6", "", "58.9", "", "2", "1", "", "102", "1", "2", "100", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.4", "100.2", "", "", "", "", "98.3"]} -{"pcdb_id": 17133, "brand_name": "Sime", "model_name": "Meridian HE", "model_qualifier": "30 C", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 56.0, "output_kw_max": 28.9, "final_year_of_manufacture": 2018, "raw": ["017133", "000213", "0", "2018/Mar/05 14:13", "Fonderie Sime S.p.A.", "Sime", "Meridian HE", "30 C", "", "2013", "2018", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28.9", "28.9", "", "", "88.3", "79.7", "", "56.0", "", "2", "", "", "104", "1", "2", "115", "4.9", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "97.4", "", "", "", "", "95.7"]} -{"pcdb_id": 17134, "brand_name": "Sime", "model_name": "Meridian HE", "model_qualifier": "30 C", "winter_efficiency_pct": 89.3, "summer_efficiency_pct": 80.7, "comparative_hot_water_efficiency_pct": 56.7, "output_kw_max": 28.9, "final_year_of_manufacture": 2018, "raw": ["017134", "000213", "0", "2018/Mar/05 14:13", "Fonderie Sime S.p.A.", "Sime", "Meridian HE", "30 C", "", "2013", "2018", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "28.9", "28.9", "", "", "89.3", "80.7", "", "56.7", "", "2", "1", "", "104", "1", "2", "115", "4.9", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.3", "99.6", "", "", "", "", "97.8"]} -{"pcdb_id": 17135, "brand_name": "Worcester", "model_name": "Greenstar Heatslave II", "model_qualifier": "12/18", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 82.2, "comparative_hot_water_efficiency_pct": 44.8, "output_kw_max": 18.0, "final_year_of_manufacture": 2015, "raw": ["017135", "000035", "0", "2024/Jan/31 10:17", "Worcester Bosch Group", "Worcester", "Greenstar Heatslave II", "12/18", "", "2013", "2015", "4", "1", "1", "2", "0", "", "", "2", "3", "1", "12", "18", "", "", "88.3", "82.2", "", "44.8", "", "2", "", "", "203", "1", "1", "230", "1.7", "1", "1", "", "42", "0", "25", "3", "84", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0123", "", "", "", "", "", "", "", "", "91.1", "95.4", "", "", "", "", "94.6"]} -{"pcdb_id": 17136, "brand_name": "Worcester", "model_name": "Greenstar Heatslave II External", "model_qualifier": "12/18", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 82.2, "comparative_hot_water_efficiency_pct": 44.8, "output_kw_max": 18.0, "final_year_of_manufacture": 2015, "raw": ["017136", "000035", "0", "2024/Jan/31 10:17", "Worcester Bosch Group", "Worcester", "Greenstar Heatslave II External", "12/18", "", "2013", "2015", "4", "1", "2", "2", "0", "", "", "2", "2", "1", "12", "18", "", "", "88.3", "82.2", "", "44.8", "", "2", "", "", "203", "1", "1", "230", "1.7", "1", "1", "", "42", "0", "25", "3", "84", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0123", "", "", "", "", "", "", "", "", "91.1", "95.4", "", "", "", "", "94.6"]} -{"pcdb_id": 17137, "brand_name": "Worcester", "model_name": "Greenstar Heatslave II", "model_qualifier": "18/25", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 82.0, "comparative_hot_water_efficiency_pct": 44.7, "output_kw_max": 25.0, "final_year_of_manufacture": 2015, "raw": ["017137", "000035", "0", "2024/Jan/31 10:17", "Worcester Bosch Group", "Worcester", "Greenstar Heatslave II", "18/25", "", "2013", "2015", "4", "1", "1", "2", "0", "", "", "2", "3", "1", "18", "25", "", "", "88.1", "82.0", "", "44.7", "", "2", "", "", "203", "1", "1", "230", "1.7", "1", "1", "", "42", "0", "25", "3", "86", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0123", "", "", "", "", "", "", "", "", "90.9", "95.1", "", "", "", "", "94.3"]} -{"pcdb_id": 17138, "brand_name": "Worcester", "model_name": "Greenstar Heatslave II External", "model_qualifier": "18/25", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 82.0, "comparative_hot_water_efficiency_pct": 44.7, "output_kw_max": 25.0, "final_year_of_manufacture": 2015, "raw": ["017138", "000035", "0", "2024/Jan/31 10:17", "Worcester Bosch Group", "Worcester", "Greenstar Heatslave II External", "18/25", "", "2013", "2015", "4", "1", "2", "2", "0", "", "", "2", "2", "1", "18", "25", "", "", "88.1", "82.0", "", "44.7", "", "2", "", "", "203", "1", "1", "230", "1.7", "1", "1", "", "42", "0", "25", "3", "86", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0123", "", "", "", "", "", "", "", "", "90.9", "95.1", "", "", "", "", "94.3"]} -{"pcdb_id": 17139, "brand_name": "Worcester", "model_name": "Greenstar Heatslave II", "model_qualifier": "25/32", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 81.8, "comparative_hot_water_efficiency_pct": 44.6, "output_kw_max": 32.0, "final_year_of_manufacture": 2015, "raw": ["017139", "000035", "0", "2024/Jan/31 10:17", "Worcester Bosch Group", "Worcester", "Greenstar Heatslave II", "25/32", "", "2013", "2015", "4", "1", "1", "2", "0", "", "", "2", "3", "1", "25", "32", "", "", "87.9", "81.8", "", "44.6", "", "2", "", "", "203", "1", "1", "250", "1.7", "1", "1", "", "42", "0", "25", "3", "88", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0123", "", "", "", "", "", "", "", "", "91.4", "94.3", "", "", "", "", "93.7"]} -{"pcdb_id": 17140, "brand_name": "Worcester", "model_name": "Greenstar Heatslave II External", "model_qualifier": "25/32", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 81.8, "comparative_hot_water_efficiency_pct": 44.6, "output_kw_max": 32.0, "final_year_of_manufacture": 2015, "raw": ["017140", "000035", "0", "2024/Jan/31 10:17", "Worcester Bosch Group", "Worcester", "Greenstar Heatslave II External", "25/32", "", "2013", "2015", "4", "1", "2", "2", "0", "", "", "2", "2", "1", "25", "32", "", "", "87.9", "81.8", "", "44.6", "", "2", "", "", "203", "1", "1", "250", "1.7", "1", "1", "", "42", "0", "25", "3", "88", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0123", "", "", "", "", "", "", "", "", "91.4", "94.3", "", "", "", "", "93.7"]} -{"pcdb_id": 17141, "brand_name": "Baxi", "model_name": "Duo-tec 2 Combi", "model_qualifier": "40", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 77.8, "output_kw_max": 32.0, "final_year_of_manufacture": 2015, "raw": ["017141", "000005", "0", "2015/Aug/06 12:22", "Baxi Heating UK", "Baxi", "Duo-tec 2 Combi", "40", "GC No. 47-075-70", "2011", "2015", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "32", "32", "", "", "88.4", "87.3", "", "77.8", "", "2", "", "", "104", "1", "2", "142", "3.5", "0", "", "", "", "0", "", "", "", "", "1", "6.765", "0.111", "0.0036", "0.69163", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.0", "96.9", "", "", "", "", "95.6"]} -{"pcdb_id": 17142, "brand_name": "Baxi", "model_name": "Duo-tec 2 Combi", "model_qualifier": "28 Compact", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 77.3, "output_kw_max": 24.0, "final_year_of_manufacture": 2015, "raw": ["017142", "000005", "0", "2015/Aug/06 12:23", "Baxi Heating UK", "Baxi", "Duo-tec 2 Combi", "28 Compact", "GC No. 47-075-72", "2013", "2015", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "88.4", "87.3", "", "77.3", "", "2", "", "", "104", "1", "2", "116", "3.5", "0", "", "", "", "0", "", "", "", "", "1", "6.813", "0.118", "0.0044", "0.73349", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.0", "96.9", "", "", "", "", "95.6"]} -{"pcdb_id": 17143, "brand_name": "Baxi", "model_name": "Duo-tec 2 Combi", "model_qualifier": "28", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 77.3, "output_kw_max": 24.0, "final_year_of_manufacture": 2015, "raw": ["017143", "000005", "0", "2015/Aug/06 12:23", "Baxi Heating UK", "Baxi", "Duo-tec 2 Combi", "28", "GV No. 47-075-68", "2013", "2015", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "88.4", "87.3", "", "77.3", "", "2", "", "", "104", "1", "2", "116", "3.5", "0", "", "", "", "0", "", "", "", "", "1", "6.813", "0.118", "0.0044", "0.73349", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.0", "96.9", "", "", "", "", "95.6"]} -{"pcdb_id": 17144, "brand_name": "Baxi", "model_name": "Megaflow 2 System", "model_qualifier": "24 Compact", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 24.0, "final_year_of_manufacture": 2015, "raw": ["017144", "000005", "0", "2015/Aug/06 12:25", "Baxi Heating UK", "Baxi", "Megaflow 2 System", "24 Compact", "GV No. 41-075-092", "2011", "2015", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24", "24", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "104", "3.5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.0", "96.9", "", "", "", "", "95.6"]} -{"pcdb_id": 17145, "brand_name": "Baxi", "model_name": "Duo-tec 2 Combi", "model_qualifier": "24", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 77.6, "output_kw_max": 20.0, "final_year_of_manufacture": 2015, "raw": ["017145", "000005", "0", "2015/Aug/06 12:25", "Baxi Heating UK", "Baxi", "Duo-tec 2 Combi", "24", "GC No. 47-075-67", "2011", "2015", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "20", "20", "", "", "88.4", "87.3", "", "77.6", "", "2", "", "", "104", "1", "2", "104", "3.5", "0", "", "", "", "0", "", "", "", "", "1", "6.786", "0.118", "0.0043", "0.70793", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.0", "96.9", "", "", "", "", "95.6"]} -{"pcdb_id": 17146, "brand_name": "Johnson & Starley", "model_name": "QuanTec", "model_qualifier": "24RK", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 23.4, "final_year_of_manufacture": null, "raw": ["017146", "000239", "0", "2015/Sep/21 14:23", "Johnson & Starley", "Johnson & Starley", "QuanTec", "24RK", "41-416-20", "2013", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "23.4", "23.4", "", "", "88.9", "79.9", "", "58.4", "", "2", "", "", "102", "1", "2", "20", "6.87", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "", "", "", "", "87.9", "99.1", "", "", "", "", "97.0"]} -{"pcdb_id": 17147, "brand_name": "Johnson & Starley", "model_name": "QuanTec", "model_qualifier": "16RK", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 16.76, "final_year_of_manufacture": null, "raw": ["017147", "000239", "0", "2015/Sep/21 14:23", "Johnson & Starley", "Johnson & Starley", "QuanTec", "16RK", "41-416-19", "2013", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "16.76", "16.76", "", "", "89.0", "80.0", "", "58.4", "", "2", "", "", "102", "1", "2", "20", "6.87", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "", "", "", "", "88.7", "98.9", "", "", "", "", "97.0"]} -{"pcdb_id": 17149, "brand_name": "Rotex", "model_name": "A1 BO 15-e", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 80.7, "comparative_hot_water_efficiency_pct": 59.0, "output_kw_max": 15.0, "final_year_of_manufacture": null, "raw": ["017149", "000246", "0", "2013/Aug/23 11:31", "Rotex Heating Systems", "Rotex", "A1 BO 15-e", "", "", "2013", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "15", "15", "", "", "88.5", "80.7", "", "59.0", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.5", "95.9", "", "", "", "", "95.0"]} -{"pcdb_id": 17150, "brand_name": "Rotex", "model_name": "A1 BO 20-e", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 80.6, "comparative_hot_water_efficiency_pct": 58.9, "output_kw_max": 20.0, "final_year_of_manufacture": null, "raw": ["017150", "000246", "0", "2013/Aug/23 11:31", "Rotex Heating Systems", "Rotex", "A1 BO 20-e", "", "", "2013", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "20", "20", "", "", "88.4", "80.6", "", "58.9", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.5", "95.5", "", "", "", "", "94.7"]} -{"pcdb_id": 17151, "brand_name": "Rotex", "model_name": "A1 BO 27-e", "model_qualifier": "", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 27.0, "final_year_of_manufacture": null, "raw": ["017151", "000246", "0", "2013/Aug/23 11:31", "Rotex Heating Systems", "Rotex", "A1 BO 27-e", "", "", "2013", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "27", "27", "", "", "87.9", "80.1", "", "58.5", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.9", "94.5", "", "", "", "", "93.8"]} -{"pcdb_id": 17152, "brand_name": "Rotex", "model_name": "A1 BO 34-e", "model_qualifier": "", "winter_efficiency_pct": 87.6, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 34.0, "final_year_of_manufacture": null, "raw": ["017152", "000246", "0", "2013/Aug/23 11:32", "Rotex Heating Systems", "Rotex", "A1 BO 34-e", "", "", "2013", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "34", "34", "", "", "87.6", "79.8", "", "58.3", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.5", "93.8", "", "", "", "", "93.2"]} -{"pcdb_id": 17157, "brand_name": "Ferroli", "model_name": "T-One", "model_qualifier": "25C HE", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 86.8, "comparative_hot_water_efficiency_pct": 71.8, "output_kw_max": 24.1, "final_year_of_manufacture": 2017, "raw": ["017157", "000097", "0", "2017/Aug/07 17:02", "Ferroli", "Ferroli", "T-One", "25C HE", "", "2013", "2017", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.1", "24.1", "", "", "88.5", "86.8", "", "71.8", "", "2", "", "", "104", "1", "2", "100", "", "0", "", "", "", "0", "", "", "", "", "1", "7.3361", "0.07487", "0.0043", "1.19581", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "98.0", "", "", "", "", "96.2"]} -{"pcdb_id": 17158, "brand_name": "Ferroli", "model_name": "Modena 32C HE", "model_qualifier": "", "winter_efficiency_pct": 89.6, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 57.0, "output_kw_max": 29.04, "final_year_of_manufacture": null, "raw": ["017158", "000097", "0", "2013/Oct/18 11:19", "Ferroli", "Ferroli", "Modena 32C HE", "", "", "2012", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "29.04", "29.04", "", "", "89.6", "81.0", "", "57.0", "", "2", "1", "", "104", "1", "2", "100", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.4", "100.3", "", "", "", "", "98.4"]} -{"pcdb_id": 17159, "brand_name": "iQE", "model_name": "Horizon", "model_qualifier": "15/26", "winter_efficiency_pct": 87.8, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 26.4, "final_year_of_manufacture": 2015, "raw": ["017159", "000276", "0", "2016/May/16 13:21", "Grant Engineering", "iQE", "Horizon", "15/26", "", "2013", "2015", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "15.9", "26.4", "", "", "87.8", "80.0", "", "58.4", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.4", "94.4", "", "", "", "", "93.6"]} -{"pcdb_id": 17160, "brand_name": "iQE", "model_name": "Horizon", "model_qualifier": "26/35", "winter_efficiency_pct": 87.5, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 35.3, "final_year_of_manufacture": 2015, "raw": ["017160", "000276", "0", "2016/May/16 13:21", "Grant Engineering", "iQE", "Horizon", "26/35", "", "2013", "2015", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "26.3", "35.3", "", "", "87.5", "79.7", "", "58.2", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.3", "93.8", "", "", "", "", "93.1"]} -{"pcdb_id": 17161, "brand_name": "iQE", "model_name": "Horizon", "model_qualifier": "OM15/26", "winter_efficiency_pct": 87.8, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 26.3, "final_year_of_manufacture": 2015, "raw": ["017161", "000276", "0", "2016/May/16 13:22", "Grant Engineering", "iQE", "Horizon", "OM15/26", "", "2013", "2015", "4", "1", "2", "1", "0", "", "", "2", "3", "2", "15.9", "26.3", "", "", "87.8", "80.0", "", "58.4", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.4", "94.4", "", "", "", "", "93.6"]} -{"pcdb_id": 17162, "brand_name": "iQE", "model_name": "Horizon", "model_qualifier": "OM26/35", "winter_efficiency_pct": 87.5, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 35.3, "final_year_of_manufacture": 2015, "raw": ["017162", "000276", "0", "2016/May/16 13:22", "Grant Engineering", "iQE", "Horizon", "OM26/35", "", "2013", "2015", "4", "1", "2", "1", "0", "", "", "2", "3", "2", "26.3", "35.3", "", "", "87.5", "79.7", "", "58.2", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.3", "93.8", "", "", "", "", "93.1"]} -{"pcdb_id": 17163, "brand_name": "iQE", "model_name": "Horizon", "model_qualifier": "COMBI26", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 81.7, "comparative_hot_water_efficiency_pct": 57.5, "output_kw_max": 26.0, "final_year_of_manufacture": 2015, "raw": ["017163", "000276", "0", "2016/May/16 13:22", "Grant Engineering", "iQE", "Horizon", "COMBI26", "", "2013", "2015", "4", "1", "1", "2", "0", "", "", "2", "3", "2", "26", "26", "", "", "89.1", "81.7", "", "57.5", "", "2", "", "", "202", "1", "1", "", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "93.6", "96.4", "", "", "", "", "95.9"]} -{"pcdb_id": 17164, "brand_name": "iQE", "model_name": "Horizon", "model_qualifier": "OMCOMBI26", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 81.7, "comparative_hot_water_efficiency_pct": 57.5, "output_kw_max": 26.0, "final_year_of_manufacture": 2015, "raw": ["017164", "000276", "0", "2016/May/16 13:22", "Grant Engineering", "iQE", "Horizon", "OMCOMBI26", "", "2013", "2015", "4", "1", "2", "2", "0", "", "", "2", "3", "2", "26", "26", "", "", "89.1", "81.7", "", "57.5", "", "2", "", "", "202", "1", "1", "", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "93.6", "96.4", "", "", "", "", "95.9"]} -{"pcdb_id": 17166, "brand_name": "Daikin", "model_name": "EHYKOMB33AA", "model_qualifier": "", "winter_efficiency_pct": 89.5, "summer_efficiency_pct": 80.9, "comparative_hot_water_efficiency_pct": 56.9, "output_kw_max": 26.6, "final_year_of_manufacture": null, "raw": ["017166", "000278", "0", "2014/Oct/15 10:21", "Daikin Europe NV", "Daikin", "EHYKOMB33AA", "", "", "2013", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "26.6", "26.6", "", "", "89.5", "80.9", "", "56.9", "", "2", "1", "", "104", "1", "2", "55", "1.9", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.9", "99.7", "", "", "", "", "98.1"]} -{"pcdb_id": 17167, "brand_name": "Daikin", "model_name": "EHYKOMB33AA", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 56.2, "output_kw_max": 26.6, "final_year_of_manufacture": null, "raw": ["017167", "000278", "0", "2013/Sep/27 09:18", "Daikin Europe NV", "Daikin", "EHYKOMB33AA", "", "GC 47-464-01", "2013", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "26.6", "26.6", "", "", "88.5", "79.9", "", "56.2", "", "2", "", "", "104", "1", "2", "55", "1.9", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.9", "97.6", "", "", "", "", "95.9"]} -{"pcdb_id": 17168, "brand_name": "Rotex", "model_name": "GCU Compact 533 BIV", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 81.2, "comparative_hot_water_efficiency_pct": 37.9, "output_kw_max": 31.0, "final_year_of_manufacture": null, "raw": ["017168", "000246", "0", "2024/Jan/31 10:17", "Rotex Heating Systems", "Rotex", "GCU Compact 533 BIV", "", "", "2013", "current", "1", "1", "1", "2", "0", "", "", "2", "3", "2", "31", "31", "", "", "88.0", "81.2", "", "37.9", "", "2", "", "", "106", "1", "2", "114", "6.7", "2", "2", "0", "500", "0", "80", "2", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "96.8", "", "", "", "", "95.1"]} -{"pcdb_id": 17169, "brand_name": "Rotex", "model_name": "GCU Compact 533", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 81.2, "comparative_hot_water_efficiency_pct": 37.9, "output_kw_max": 31.0, "final_year_of_manufacture": null, "raw": ["017169", "000246", "0", "2024/Jan/31 10:17", "Rotex Heating Systems", "Rotex", "GCU Compact 533", "", "", "2013", "current", "1", "1", "1", "2", "0", "", "", "2", "3", "2", "31", "31", "", "", "88.0", "81.2", "", "37.9", "", "2", "", "", "106", "1", "2", "114", "6.7", "2", "2", "0", "500", "0", "80", "2", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "96.8", "", "", "", "", "95.1"]} -{"pcdb_id": 17170, "brand_name": "Rotex", "model_name": "GCU Compact 524 BIV", "model_qualifier": "", "winter_efficiency_pct": 87.3, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 37.6, "output_kw_max": 24.0, "final_year_of_manufacture": null, "raw": ["017170", "000246", "0", "2024/Jan/31 10:17", "Rotex Heating Systems", "Rotex", "GCU Compact 524 BIV", "", "", "2013", "current", "1", "1", "1", "2", "0", "", "", "2", "3", "2", "24", "24", "", "", "87.3", "80.5", "", "37.6", "", "2", "", "", "106", "1", "2", "112", "6.7", "2", "2", "0", "500", "0", "80", "2", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "85.8", "96.0", "", "", "", "", "94.1"]} -{"pcdb_id": 17171, "brand_name": "Rotex", "model_name": "GCU Compact 524", "model_qualifier": "", "winter_efficiency_pct": 87.3, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 37.6, "output_kw_max": 24.0, "final_year_of_manufacture": null, "raw": ["017171", "000246", "0", "2024/Jan/31 10:17", "Rotex Heating Systems", "Rotex", "GCU Compact 524", "", "", "2013", "current", "1", "1", "1", "2", "0", "", "", "2", "3", "2", "24", "24", "", "", "87.3", "80.5", "", "37.6", "", "2", "", "", "106", "1", "2", "112", "6.7", "2", "2", "0", "500", "0", "80", "2", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "85.8", "96.0", "", "", "", "", "94.1"]} -{"pcdb_id": 17172, "brand_name": "Rotex", "model_name": "GCU Compact 515 BIV", "model_qualifier": "", "winter_efficiency_pct": 87.7, "summer_efficiency_pct": 80.9, "comparative_hot_water_efficiency_pct": 37.8, "output_kw_max": 33.0, "final_year_of_manufacture": null, "raw": ["017172", "000246", "0", "2024/Jan/31 10:17", "Rotex Heating Systems", "Rotex", "GCU Compact 515 BIV", "", "", "2013", "current", "1", "1", "1", "2", "0", "", "", "2", "3", "2", "33", "33", "", "", "87.7", "80.9", "", "37.8", "", "2", "", "", "106", "1", "2", "96.1", "6.7", "2", "2", "0", "500", "0", "80", "2", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.1", "96.3", "", "", "", "", "94.6"]} -{"pcdb_id": 17173, "brand_name": "Rotex", "model_name": "GCU Compact 515", "model_qualifier": "", "winter_efficiency_pct": 87.7, "summer_efficiency_pct": 80.9, "comparative_hot_water_efficiency_pct": 37.8, "output_kw_max": 15.0, "final_year_of_manufacture": null, "raw": ["017173", "000246", "0", "2024/Jan/31 10:17", "Rotex Heating Systems", "Rotex", "GCU Compact 515", "", "", "2013", "current", "1", "1", "1", "2", "0", "", "", "2", "3", "2", "15", "15", "", "", "87.7", "80.9", "", "37.8", "", "2", "", "", "106", "1", "2", "96.1", "6.7", "2", "2", "0", "500", "0", "80", "2", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.1", "96.3", "", "", "", "", "94.6"]} -{"pcdb_id": 17174, "brand_name": "Rotex", "model_name": "GCU Compact 324 BIV", "model_qualifier": "", "winter_efficiency_pct": 87.3, "summer_efficiency_pct": 80.4, "comparative_hot_water_efficiency_pct": 39.4, "output_kw_max": 24.0, "final_year_of_manufacture": null, "raw": ["017174", "000246", "0", "2024/Jan/31 10:17", "Rotex Heating Systems", "Rotex", "GCU Compact 324 BIV", "", "", "2013", "current", "1", "1", "1", "2", "0", "", "", "2", "3", "2", "24", "24", "", "", "87.3", "80.4", "", "39.4", "", "2", "", "", "106", "1", "2", "112", "6.7", "2", "2", "0", "300", "0", "52", "2", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "85.8", "96.0", "", "", "", "", "94.1"]} -{"pcdb_id": 17175, "brand_name": "Rotex", "model_name": "GCU Compact 324", "model_qualifier": "", "winter_efficiency_pct": 87.3, "summer_efficiency_pct": 80.4, "comparative_hot_water_efficiency_pct": 39.4, "output_kw_max": 24.0, "final_year_of_manufacture": null, "raw": ["017175", "000246", "0", "2024/Jan/31 10:17", "Rotex Heating Systems", "Rotex", "GCU Compact 324", "", "", "2013", "current", "1", "1", "1", "2", "0", "", "", "2", "3", "2", "24", "24", "", "", "87.3", "80.4", "", "39.4", "", "2", "", "", "106", "1", "2", "112", "6.7", "2", "2", "0", "300", "0", "52", "2", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "85.8", "96.0", "", "", "", "", "94.1"]} -{"pcdb_id": 17176, "brand_name": "Rotex", "model_name": "GCU Compact 315 BIV", "model_qualifier": "", "winter_efficiency_pct": 87.7, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 39.6, "output_kw_max": 15.0, "final_year_of_manufacture": null, "raw": ["017176", "000246", "0", "2024/Jan/31 10:17", "Rotex Heating Systems", "Rotex", "GCU Compact 315 BIV", "", "", "2013", "current", "1", "1", "1", "2", "0", "", "", "2", "3", "2", "15", "15", "", "", "87.7", "80.8", "", "39.6", "", "2", "", "", "106", "1", "2", "96.1", "6.7", "2", "2", "0", "300", "0", "52", "2", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.1", "96.3", "", "", "", "", "94.6"]} -{"pcdb_id": 17177, "brand_name": "Rotex", "model_name": "GCU Compact 315", "model_qualifier": "", "winter_efficiency_pct": 87.7, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 39.6, "output_kw_max": 15.0, "final_year_of_manufacture": null, "raw": ["017177", "000246", "0", "2024/Jan/31 10:17", "Rotex Heating Systems", "Rotex", "GCU Compact 315", "", "", "2013", "current", "1", "1", "1", "2", "0", "", "", "2", "3", "2", "15", "15", "", "", "87.7", "80.8", "", "39.6", "", "2", "", "", "106", "1", "2", "96.1", "6.7", "2", "2", "0", "300", "0", "52", "2", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.1", "96.3", "", "", "", "", "94.6"]} -{"pcdb_id": 17178, "brand_name": "Ideal", "model_name": "LOGIC CODE COMBI", "model_qualifier": "ES26", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 79.0, "output_kw_max": 24.2, "final_year_of_manufacture": 2016, "raw": ["017178", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "LOGIC CODE COMBI", "ES26", "47-349-04", "2013", "2016", "1", "2", "1", "2", "1", "", "", "2", "2", "2", "24.2", "24.2", "", "", "88.4", "87.3", "", "79.0", "", "2", "", "", "104", "1", "2", "146", "1", "0", "", "", "", "0", "", "", "", "", "1", "6.667", "0.1818", "0.0013", "0.60624", "", "", "", "", "", "0", "", "", "0035", "", "", "", "", "", "", "", "", "89.8", "96.9", "", "", "", "", "95.6"]} -{"pcdb_id": 17179, "brand_name": "Ideal", "model_name": "LOGIC CODE COMBI", "model_qualifier": "ES33", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 81.4, "output_kw_max": 24.2, "final_year_of_manufacture": 2016, "raw": ["017179", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "LOGIC CODE COMBI", "ES33", "47-349-05", "2013", "2016", "1", "2", "1", "2", "1", "", "", "2", "2", "2", "24.2", "24.2", "", "", "88.4", "87.3", "", "81.4", "", "2", "", "", "104", "1", "2", "152", "1", "0", "", "", "", "0", "", "", "", "", "1", "6.468", "0.1831", "0.003", "0.40776", "", "", "", "", "", "0", "", "", "0035", "", "", "", "", "", "", "", "", "90.0", "96.9", "", "", "", "", "95.6"]} -{"pcdb_id": 17180, "brand_name": "Ideal", "model_name": "LOGIC CODE COMBI", "model_qualifier": "ES38", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 80.4, "output_kw_max": 24.2, "final_year_of_manufacture": 2016, "raw": ["017180", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "LOGIC CODE COMBI", "ES38", "47-349-06", "2013", "2016", "1", "2", "1", "2", "1", "", "", "2", "2", "2", "24.2", "24.2", "", "", "88.3", "87.3", "", "80.4", "", "2", "", "", "104", "1", "2", "177", "1", "0", "", "", "", "0", "", "", "", "", "1", "6.5486", "0.1612", "0.0011", "0.49271", "", "", "", "", "", "0", "", "", "0035", "", "", "", "", "", "", "", "", "89.8", "96.9", "", "", "", "", "95.5"]} -{"pcdb_id": 17181, "brand_name": "Ideal", "model_name": "Project Heat", "model_qualifier": "15", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 15.0, "final_year_of_manufacture": 2014, "raw": ["017181", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "Project Heat", "15", "41-750-57", "2013", "2014", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "15", "15", "", "", "88.6", "79.6", "", "58.2", "", "2", "", "", "102", "1", "2", "26", "1", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.7", "97.7", "", "", "", "", "96.2"]} -{"pcdb_id": 17182, "brand_name": "Ideal", "model_name": "Project Heat", "model_qualifier": "24", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 24.2, "final_year_of_manufacture": 2014, "raw": ["017182", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "Project Heat", "24", "41-750-58", "2013", "2014", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "88.8", "79.8", "", "58.3", "", "2", "", "", "102", "1", "2", "46", "1", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.6", "98.0", "", "", "", "", "96.4"]} -{"pcdb_id": 17183, "brand_name": "Ideal", "model_name": "Project System", "model_qualifier": "15", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 15.0, "final_year_of_manufacture": 2014, "raw": ["017183", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "Project System", "15", "41-750-59", "2013", "2014", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "15", "15", "", "", "88.6", "79.6", "", "58.2", "", "2", "", "", "102", "1", "2", "126", "1", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.7", "97.7", "", "", "", "", "96.2"]} -{"pcdb_id": 17184, "brand_name": "Ideal", "model_name": "Project System", "model_qualifier": "24", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 24.2, "final_year_of_manufacture": 2014, "raw": ["017184", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "Project System", "24", "41-750-60", "2013", "2014", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "88.8", "79.8", "", "58.3", "", "2", "", "", "102", "1", "2", "146", "1", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.6", "98.0", "", "", "", "", "96.4"]} -{"pcdb_id": 17185, "brand_name": "iQE", "model_name": "Comfort", "model_qualifier": "30", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 56.0, "output_kw_max": 28.9, "final_year_of_manufacture": null, "raw": ["017185", "000273", "0", "2015/Oct/01 13:44", "Fonderie Sime S.p.A.", "iQE", "Comfort", "30", "47-283-47", "2013", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28.9", "28.9", "", "", "88.3", "79.7", "", "56.0", "", "2", "", "", "104", "1", "2", "115", "4.9", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "97.4", "", "", "", "", "95.7"]} -{"pcdb_id": 17186, "brand_name": "iQE", "model_name": "Comfort", "model_qualifier": "30", "winter_efficiency_pct": 89.3, "summer_efficiency_pct": 80.7, "comparative_hot_water_efficiency_pct": 56.7, "output_kw_max": 28.9, "final_year_of_manufacture": null, "raw": ["017186", "000273", "0", "2015/Oct/01 13:44", "Fonderie Sime S.p.A.", "iQE", "Comfort", "30", "", "2013", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "28.9", "28.9", "", "", "89.3", "80.7", "", "56.7", "", "2", "1", "", "104", "1", "2", "115", "4.9", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.3", "99.6", "", "", "", "", "97.8"]} -{"pcdb_id": 17187, "brand_name": "Worcester", "model_name": "Greenstar Danesmoor System External", "model_qualifier": "12/18", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 58.8, "output_kw_max": 18.0, "final_year_of_manufacture": 2015, "raw": ["017187", "000035", "0", "2020/Sep/08 10:41", "Bosch Thermotechnology", "Worcester", "Greenstar Danesmoor System External", "12/18", "", "2013", "2015", "4", "1", "2", "1", "0", "", "", "2", "2", "1", "12", "18", "", "", "88.3", "80.5", "", "58.8", "", "2", "", "", "201", "1", "1", "208", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.1", "95.4", "", "", "", "", "94.6"]} -{"pcdb_id": 17188, "brand_name": "Worcester", "model_name": "Greenstar Danesmoor System External", "model_qualifier": "18/25", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 58.7, "output_kw_max": 25.0, "final_year_of_manufacture": 2015, "raw": ["017188", "000035", "0", "2020/Sep/08 10:42", "Bosch Thermotechnology", "Worcester", "Greenstar Danesmoor System External", "18/25", "", "2013", "2015", "4", "1", "2", "1", "0", "", "", "2", "2", "1", "18", "25", "", "", "88.1", "80.3", "", "58.7", "", "2", "", "", "201", "1", "1", "208", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.9", "95.1", "", "", "", "", "94.3"]} -{"pcdb_id": 17189, "brand_name": "Worcester", "model_name": "Greenstar Danesmoor System External", "model_qualifier": "25/32", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 32.0, "final_year_of_manufacture": 2015, "raw": ["017189", "000035", "0", "2020/Sep/08 10:42", "Bosch Thermotechnology", "Worcester", "Greenstar Danesmoor System External", "25/32", "", "2013", "2015", "4", "1", "2", "1", "0", "", "", "2", "2", "1", "25", "32", "", "", "87.9", "80.1", "", "58.5", "", "2", "", "", "201", "1", "1", "208", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.4", "94.3", "", "", "", "", "93.7"]} -{"pcdb_id": 17190, "brand_name": "Worcester", "model_name": "Greenstar Danesmoor System", "model_qualifier": "12/18", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 58.8, "output_kw_max": 18.0, "final_year_of_manufacture": 2015, "raw": ["017190", "000035", "0", "2020/Sep/08 10:42", "Bosch Thermotechnology", "Worcester", "Greenstar Danesmoor System", "12/18", "", "2013", "2015", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "12", "18", "", "", "88.3", "80.5", "", "58.8", "", "2", "", "", "201", "1", "1", "208", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.1", "95.4", "", "", "", "", "94.6"]} -{"pcdb_id": 17191, "brand_name": "Worcester", "model_name": "Greenstar Danesmoor System", "model_qualifier": "18/25", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 58.7, "output_kw_max": 25.0, "final_year_of_manufacture": 2015, "raw": ["017191", "000035", "0", "2020/Sep/08 10:42", "Bosch Thermotechnology", "Worcester", "Greenstar Danesmoor System", "18/25", "", "2013", "2015", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "18", "25", "", "", "88.1", "80.3", "", "58.7", "", "2", "", "", "201", "1", "1", "208", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.9", "95.1", "", "", "", "", "94.3"]} -{"pcdb_id": 17192, "brand_name": "Worcester", "model_name": "Greenstar Danesmoor System", "model_qualifier": "25/32", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 32.0, "final_year_of_manufacture": 2015, "raw": ["017192", "000035", "0", "2020/Sep/08 10:42", "Bosch Thermotechnology", "Worcester", "Greenstar Danesmoor System", "25/32", "", "2013", "2015", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "25", "32", "", "", "87.9", "80.1", "", "58.5", "", "2", "", "", "201", "1", "1", "208", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.4", "94.3", "", "", "", "", "93.7"]} -{"pcdb_id": 17193, "brand_name": "Worcester", "model_name": "Greenstar Danesmoor System Utility", "model_qualifier": "12/18", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 58.8, "output_kw_max": 18.0, "final_year_of_manufacture": 2015, "raw": ["017193", "000035", "0", "2020/Sep/08 10:42", "Bosch Thermotechnology", "Worcester", "Greenstar Danesmoor System Utility", "12/18", "", "2013", "2015", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "12", "18", "", "", "88.3", "80.5", "", "58.8", "", "2", "", "", "201", "1", "1", "208", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.1", "95.4", "", "", "", "", "94.6"]} -{"pcdb_id": 17194, "brand_name": "Worcester", "model_name": "Greenstar Danesmoor System Utility", "model_qualifier": "18/25", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 58.7, "output_kw_max": 25.0, "final_year_of_manufacture": 2015, "raw": ["017194", "000035", "0", "2020/Sep/08 10:42", "Bosch Thermotechnology", "Worcester", "Greenstar Danesmoor System Utility", "18/25", "", "2013", "2015", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "18", "25", "", "", "88.1", "80.3", "", "58.7", "", "2", "", "", "201", "1", "1", "208", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.9", "95.1", "", "", "", "", "94.3"]} -{"pcdb_id": 17195, "brand_name": "Worcester", "model_name": "Greenstar Danesmoor System Utility", "model_qualifier": "25/32", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 32.0, "final_year_of_manufacture": 2015, "raw": ["017195", "000035", "0", "2020/Sep/08 10:42", "Bosch Thermotechnology", "Worcester", "Greenstar Danesmoor System Utility", "25/32", "", "2013", "2015", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "25", "32", "", "", "87.9", "80.1", "", "58.5", "", "2", "", "", "201", "1", "1", "208", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.4", "94.3", "", "", "", "", "93.7"]} -{"pcdb_id": 17196, "brand_name": "Rotex", "model_name": "GCU Compact 315", "model_qualifier": "", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 81.8, "comparative_hot_water_efficiency_pct": 40.1, "output_kw_max": 15.0, "final_year_of_manufacture": null, "raw": ["017196", "000246", "0", "2024/Jan/31 10:17", "Rotex Heating Systems", "Rotex", "GCU Compact 315", "", "", "2013", "current", "2", "1", "1", "2", "0", "", "", "2", "3", "2", "15", "15", "", "", "88.7", "81.8", "", "40.1", "", "2", "1", "", "106", "1", "2", "96.1", "6.7", "2", "2", "1", "300", "0", "52", "2", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.1", "98.5", "", "", "", "", "96.7"]} -{"pcdb_id": 17197, "brand_name": "Rotex", "model_name": "GCU Compact 315 BIV", "model_qualifier": "", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 81.8, "comparative_hot_water_efficiency_pct": 40.1, "output_kw_max": 15.0, "final_year_of_manufacture": null, "raw": ["017197", "000246", "0", "2024/Jan/31 10:17", "Rotex Heating Systems", "Rotex", "GCU Compact 315 BIV", "", "", "2013", "current", "2", "1", "2", "2", "0", "", "", "2", "3", "2", "15", "15", "", "", "88.7", "81.8", "", "40.1", "", "2", "1", "", "106", "1", "2", "96.1", "6.7", "2", "2", "", "300", "0", "52", "2", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.1", "98.5", "", "", "", "", "96.7"]} -{"pcdb_id": 17198, "brand_name": "Rotex", "model_name": "GCU Compact 324", "model_qualifier": "", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 81.4, "comparative_hot_water_efficiency_pct": 39.9, "output_kw_max": 24.0, "final_year_of_manufacture": null, "raw": ["017198", "000246", "0", "2024/Jan/31 10:17", "Rotex Heating Systems", "Rotex", "GCU Compact 324", "", "", "2013", "current", "2", "1", "1", "2", "0", "", "", "2", "3", "2", "24", "24", "", "", "88.2", "81.4", "", "39.9", "", "2", "1", "", "106", "1", "2", "112", "6.7", "2", "2", "0", "300", "0", "52", "2", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.7", "98.2", "", "", "", "", "96.2"]} -{"pcdb_id": 17199, "brand_name": "Rotex", "model_name": "GCU Compact 324 BIV", "model_qualifier": "", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 81.4, "comparative_hot_water_efficiency_pct": 39.9, "output_kw_max": 24.0, "final_year_of_manufacture": null, "raw": ["017199", "000246", "0", "2024/Jan/31 10:17", "Rotex Heating Systems", "Rotex", "GCU Compact 324 BIV", "", "", "2013", "current", "2", "1", "1", "2", "0", "", "", "2", "3", "2", "24", "24", "", "", "88.2", "81.4", "", "39.9", "", "2", "1", "", "106", "1", "2", "112", "6.7", "2", "2", "0", "300", "0", "52", "2", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.7", "98.2", "", "", "", "", "96.2"]} -{"pcdb_id": 17200, "brand_name": "Rotex", "model_name": "GCU Compact 515", "model_qualifier": "", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 81.9, "comparative_hot_water_efficiency_pct": 38.2, "output_kw_max": 15.0, "final_year_of_manufacture": null, "raw": ["017200", "000246", "0", "2024/Jan/31 10:17", "Rotex Heating Systems", "Rotex", "GCU Compact 515", "", "", "2013", "current", "2", "1", "1", "2", "0", "", "", "2", "3", "2", "15", "15", "", "", "88.7", "81.9", "", "38.2", "", "2", "1", "", "106", "1", "2", "96.1", "6.7", "2", "2", "0", "500", "0", "80", "2", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.1", "98.5", "", "", "", "", "96.7"]} -{"pcdb_id": 17201, "brand_name": "Rotex", "model_name": "GCU Compact 515 BIV", "model_qualifier": "", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 81.9, "comparative_hot_water_efficiency_pct": 38.2, "output_kw_max": 15.0, "final_year_of_manufacture": null, "raw": ["017201", "000246", "0", "2024/Jan/31 10:17", "Rotex Heating Systems", "Rotex", "GCU Compact 515 BIV", "", "", "2013", "current", "2", "1", "1", "2", "0", "", "", "2", "3", "2", "15", "15", "", "", "88.7", "81.9", "", "38.2", "", "2", "1", "", "106", "1", "2", "96.1", "6.7", "2", "2", "0", "500", "0", "80", "2", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.1", "98.5", "", "", "", "", "96.7"]} -{"pcdb_id": 17202, "brand_name": "Rotex", "model_name": "GCU Compact 524", "model_qualifier": "", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 81.4, "comparative_hot_water_efficiency_pct": 38.0, "output_kw_max": 24.0, "final_year_of_manufacture": null, "raw": ["017202", "000246", "0", "2024/Jan/31 10:17", "Rotex Heating Systems", "Rotex", "GCU Compact 524", "", "", "2013", "current", "2", "1", "1", "2", "0", "", "", "2", "3", "2", "24", "24", "", "", "88.2", "81.4", "", "38.0", "", "2", "1", "", "106", "1", "2", "112", "6.7", "2", "2", "0", "500", "0", "80", "2", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.7", "98.2", "", "", "", "", "96.2"]} -{"pcdb_id": 17203, "brand_name": "Rotex", "model_name": "GCU Compact 524 BIV", "model_qualifier": "", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 81.4, "comparative_hot_water_efficiency_pct": 38.0, "output_kw_max": 24.0, "final_year_of_manufacture": null, "raw": ["017203", "000246", "0", "2024/Jan/31 10:17", "Rotex Heating Systems", "Rotex", "GCU Compact 524 BIV", "", "", "2013", "current", "2", "1", "1", "2", "0", "", "", "2", "3", "2", "24", "24", "", "", "88.2", "81.4", "", "38.0", "", "2", "1", "", "106", "1", "2", "112", "6.7", "2", "2", "0", "500", "0", "80", "2", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.7", "98.2", "", "", "", "", "96.2"]} -{"pcdb_id": 17204, "brand_name": "Rotex", "model_name": "GCU Compact 533", "model_qualifier": "", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 82.2, "comparative_hot_water_efficiency_pct": 38.4, "output_kw_max": 29.0, "final_year_of_manufacture": null, "raw": ["017204", "000246", "0", "2024/Jan/31 10:17", "Rotex Heating Systems", "Rotex", "GCU Compact 533", "", "", "2013", "current", "2", "1", "1", "2", "0", "", "", "2", "3", "2", "29", "29", "", "", "88.9", "82.2", "", "38.4", "", "2", "1", "", "106", "1", "2", "114", "6.7", "2", "2", "0", "500", "0", "80", "2", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.7", "98.9", "", "", "", "", "97.2"]} -{"pcdb_id": 17205, "brand_name": "Rotex", "model_name": "GCU Compact 533 BIV", "model_qualifier": "", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 82.2, "comparative_hot_water_efficiency_pct": 38.4, "output_kw_max": 29.0, "final_year_of_manufacture": null, "raw": ["017205", "000246", "0", "2024/Jan/31 10:17", "Rotex Heating Systems", "Rotex", "GCU Compact 533 BIV", "", "", "2013", "current", "2", "1", "1", "2", "0", "", "", "2", "3", "2", "29", "29", "", "", "88.9", "82.2", "", "38.4", "", "2", "1", "", "106", "1", "2", "114", "6.7", "2", "2", "0", "500", "0", "80", "2", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.7", "98.9", "", "", "", "", "97.2"]} -{"pcdb_id": 17206, "brand_name": "Ferroli", "model_name": "T-One", "model_qualifier": "30C HE", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 86.8, "comparative_hot_water_efficiency_pct": 74.6, "output_kw_max": 29.5, "final_year_of_manufacture": 2017, "raw": ["017206", "000097", "0", "2017/Aug/07 17:02", "Ferroli", "Ferroli", "T-One", "30C HE", "", "2013", "2017", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "29.5", "29.5", "", "", "88.6", "86.8", "", "74.6", "", "2", "", "", "104", "1", "2", "100", "", "0", "", "", "", "0", "", "", "", "", "1", "7.0627", "0.07685", "0.0004", "0.95759", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.4", "98.1", "", "", "", "", "96.3"]} -{"pcdb_id": 17211, "brand_name": "Morco", "model_name": "GB30", "model_qualifier": "", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 63.0, "output_kw_max": 24.2, "final_year_of_manufacture": null, "raw": ["017211", "000282", "0", "2013/Nov/29 09:25", "Morco Products Ltd", "Morco", "GB30", "", "", "2013", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "89.4", "80.8", "", "63.0", "", "2", "1", "", "104", "1", "2", "152", "1", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "", "0035", "", "", "", "", "", "", "", "", "92.0", "99.0", "", "", "", "", "97.7"]} -{"pcdb_id": 17212, "brand_name": "Morco", "model_name": "GB24-NG", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 62.2, "output_kw_max": 24.2, "final_year_of_manufacture": null, "raw": ["017212", "000282", "0", "2013/Nov/29 09:25", "Morco Products Ltd", "Morco", "GB24-NG", "", "", "2013", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "88.3", "79.7", "", "62.2", "", "2", "", "", "104", "1", "2", "146", "1", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "", "0035", "", "", "", "", "", "", "", "", "89.8", "96.9", "", "", "", "", "95.5"]} -{"pcdb_id": 17213, "brand_name": "Morco", "model_name": "GB24", "model_qualifier": "", "winter_efficiency_pct": 89.3, "summer_efficiency_pct": 80.7, "comparative_hot_water_efficiency_pct": 63.0, "output_kw_max": 24.2, "final_year_of_manufacture": null, "raw": ["017213", "000282", "0", "2013/Nov/29 09:25", "Morco Products Ltd", "Morco", "GB24", "", "", "2013", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "89.3", "80.7", "", "63.0", "", "2", "1", "", "104", "1", "2", "146", "1", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "", "0035", "", "", "", "", "", "", "", "", "91.8", "99.0", "", "", "", "", "97.6"]} -{"pcdb_id": 17214, "brand_name": "Morco", "model_name": "GB30-NG", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 62.3, "output_kw_max": 24.2, "final_year_of_manufacture": null, "raw": ["017214", "000282", "0", "2013/Nov/29 09:25", "Morco Products Ltd", "Morco", "GB30-NG", "", "", "2013", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "88.4", "79.8", "", "62.3", "", "2", "", "", "104", "1", "2", "152", "1", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "", "0035", "", "", "", "", "", "", "", "", "90.0", "96.9", "", "", "", "", "95.6"]} -{"pcdb_id": 17215, "brand_name": "Vokera", "model_name": "Excel", "model_qualifier": "29", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 86.7, "comparative_hot_water_efficiency_pct": 71.9, "output_kw_max": 24.45, "final_year_of_manufacture": null, "raw": ["017215", "000011", "0", "2015/Mar/04 16:44", "Vokera", "Vokera", "Excel", "29", "47 364 13", "2013", "current", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "24.45", "24.45", "", "", "88.4", "86.7", "", "71.9", "", "2", "", "", "104", "1", "2", "110", "4.5", "0", "", "", "", "0", "", "", "", "", "1", "7.325", "0.103", "0.003", "1.18793", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "", "", "", "", "88.1", "97.7", "", "", "", "", "95.9"]} -{"pcdb_id": 17216, "brand_name": "Vokera", "model_name": "Excel", "model_qualifier": "25", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 86.6, "comparative_hot_water_efficiency_pct": 72.0, "output_kw_max": 19.5, "final_year_of_manufacture": null, "raw": ["017216", "000011", "0", "2015/Mar/04 16:44", "Vokera", "Vokera", "Excel", "25", "47 364 12", "2013", "current", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "19.5", "19.5", "", "", "88.5", "86.6", "", "72.0", "", "2", "", "", "104", "1", "2", "110", "4.5", "0", "", "", "", "0", "", "", "", "", "1", "7.315", "0.105", "0.003", "1.17113", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "", "", "", "", "87.8", "98.1", "", "", "", "", "96.2"]} -{"pcdb_id": 17217, "brand_name": "Ferroli", "model_name": "T-One", "model_qualifier": "25C HE", "winter_efficiency_pct": 89.6, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 56.9, "output_kw_max": 24.5, "final_year_of_manufacture": 2017, "raw": ["017217", "000097", "0", "2017/Aug/21 13:41", "Ferroli", "Ferroli", "T-One", "25C HE", "", "2013", "2017", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24.5", "24.5", "", "", "89.6", "81.0", "", "56.9", "", "2", "1", "", "104", "1", "2", "100", "3.2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.4", "100.2", "", "", "", "", "98.3"]} -{"pcdb_id": 17218, "brand_name": "Sabre", "model_name": "25 HE Plus", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 56.1, "output_kw_max": 19.5, "final_year_of_manufacture": null, "raw": ["017218", "000011", "0", "2013/Dec/12 12:24", "Vokera", "Sabre", "25 HE Plus", "", "47 364 08", "2010", "current", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "19.5", "19.5", "", "", "88.4", "79.8", "", "56.1", "", "2", "", "", "104", "1", "2", "123", "4.5", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "97.8", "", "", "", "", "95.9"]} -{"pcdb_id": 17219, "brand_name": "Sabre", "model_name": "29 HE Plus", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 56.0, "output_kw_max": 24.4, "final_year_of_manufacture": null, "raw": ["017219", "000011", "0", "2013/Dec/12 12:24", "Vokera", "Sabre", "29 HE Plus", "", "47 364 09", "2010", "current", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "24.4", "24.4", "", "", "88.3", "79.7", "", "56.0", "", "2", "", "", "104", "1", "2", "140", "4.5", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "97.6", "", "", "", "", "95.7"]} -{"pcdb_id": 17220, "brand_name": "Potterton", "model_name": "Profile", "model_qualifier": "18HO", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 17.6, "final_year_of_manufacture": null, "raw": ["017220", "000005", "0", "2014/Jan/27 10:41", "Baxi Heating UK", "Potterton", "Profile", "18HO", "", "2014", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "17.6", "17.6", "", "", "88.5", "79.5", "", "58.1", "", "2", "", "", "102", "1", "2", "50", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.6", "97.9", "", "", "", "", "96.2"]} -{"pcdb_id": 17221, "brand_name": "Potterton", "model_name": "Profile", "model_qualifier": "18HO", "winter_efficiency_pct": 89.6, "summer_efficiency_pct": 80.6, "comparative_hot_water_efficiency_pct": 58.8, "output_kw_max": 17.6, "final_year_of_manufacture": null, "raw": ["017221", "000005", "0", "2014/Jan/27 10:42", "Baxi Heating UK", "Potterton", "Profile", "18HO", "", "2014", "current", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "17.6", "17.6", "", "", "89.6", "80.6", "", "58.8", "", "2", "1", "", "102", "1", "2", "50", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.5", "100.1", "", "", "", "", "98.3"]} -{"pcdb_id": 17222, "brand_name": "Potterton", "model_name": "Profile", "model_qualifier": "24HO", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 24.7, "final_year_of_manufacture": null, "raw": ["017222", "000005", "0", "2014/Jan/27 10:42", "Baxi Heating UK", "Potterton", "Profile", "24HO", "", "2014", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "24.7", "24.7", "", "", "88.9", "79.9", "", "58.4", "", "2", "", "", "102", "1", "2", "50", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.5", "98.8", "", "", "", "", "96.9"]} -{"pcdb_id": 17223, "brand_name": "Potterton", "model_name": "Profile", "model_qualifier": "24HO", "winter_efficiency_pct": 89.9, "summer_efficiency_pct": 80.9, "comparative_hot_water_efficiency_pct": 59.1, "output_kw_max": 24.7, "final_year_of_manufacture": null, "raw": ["017223", "000005", "0", "2014/Jan/27 10:42", "Baxi Heating UK", "Potterton", "Profile", "24HO", "", "2014", "current", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "24.7", "24.7", "", "", "89.9", "80.9", "", "59.1", "", "2", "1", "", "102", "1", "2", "50", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.4", "101.0", "", "", "", "", "99.0"]} -{"pcdb_id": 17224, "brand_name": "Potterton", "model_name": "Profile", "model_qualifier": "30HO", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 29.4, "final_year_of_manufacture": null, "raw": ["017224", "000005", "0", "2014/Jan/27 10:42", "Baxi Heating UK", "Potterton", "Profile", "30HO", "", "2014", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "29.4", "29.4", "", "", "88.9", "79.9", "", "58.4", "", "2", "", "", "102", "1", "2", "115", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.5", "98.8", "", "", "", "", "96.9"]} -{"pcdb_id": 17225, "brand_name": "Potterton", "model_name": "Profile", "model_qualifier": "30HO", "winter_efficiency_pct": 89.9, "summer_efficiency_pct": 80.9, "comparative_hot_water_efficiency_pct": 59.1, "output_kw_max": 29.4, "final_year_of_manufacture": null, "raw": ["017225", "000005", "0", "2014/Jan/27 10:42", "Baxi Heating UK", "Potterton", "Profile", "30HO", "", "2014", "current", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "29.4", "29.4", "", "", "89.9", "80.9", "", "59.1", "", "2", "1", "", "102", "1", "2", "115", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.4", "101.0", "", "", "", "", "99.0"]} -{"pcdb_id": 17226, "brand_name": "Potterton", "model_name": "Profile", "model_qualifier": "18S", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 17.6, "final_year_of_manufacture": null, "raw": ["017226", "000005", "0", "2014/Jan/27 10:42", "Baxi Heating UK", "Potterton", "Profile", "18S", "", "2014", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "17.6", "17.6", "", "", "88.5", "79.5", "", "58.1", "", "2", "", "", "102", "1", "2", "115", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.6", "97.9", "", "", "", "", "96.2"]} -{"pcdb_id": 17227, "brand_name": "Potterton", "model_name": "Profile", "model_qualifier": "18S", "winter_efficiency_pct": 89.6, "summer_efficiency_pct": 80.6, "comparative_hot_water_efficiency_pct": 58.8, "output_kw_max": 17.6, "final_year_of_manufacture": null, "raw": ["017227", "000005", "0", "2014/Jan/27 10:42", "Baxi Heating UK", "Potterton", "Profile", "18S", "", "2014", "current", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "17.6", "17.6", "", "", "89.6", "80.6", "", "58.8", "", "2", "1", "", "102", "1", "2", "115", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.5", "100.1", "", "", "", "", "98.3"]} -{"pcdb_id": 17228, "brand_name": "Potterton", "model_name": "Profile", "model_qualifier": "24S", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 21.6, "final_year_of_manufacture": null, "raw": ["017228", "000005", "0", "2014/Jan/27 10:42", "Baxi Heating UK", "Potterton", "Profile", "24S", "", "2014", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "21.6", "21.6", "", "", "88.5", "79.5", "", "58.1", "", "2", "", "", "102", "1", "2", "115", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.6", "97.9", "", "", "", "", "96.2"]} -{"pcdb_id": 17229, "brand_name": "Potterton", "model_name": "Profile", "model_qualifier": "24s", "winter_efficiency_pct": 89.6, "summer_efficiency_pct": 80.6, "comparative_hot_water_efficiency_pct": 58.8, "output_kw_max": 21.6, "final_year_of_manufacture": null, "raw": ["017229", "000005", "0", "2014/Feb/24 11:09", "Baxi Heating UK", "Potterton", "Profile", "24s", "", "2014", "current", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "21.6", "21.6", "", "", "89.6", "80.6", "", "58.8", "", "2", "1", "", "102", "1", "2", "115", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.5", "100.1", "", "", "", "", "98.3"]} -{"pcdb_id": 17230, "brand_name": "Potterton", "model_name": "Profile", "model_qualifier": "30S", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 29.4, "final_year_of_manufacture": null, "raw": ["017230", "000005", "0", "2014/Jan/27 10:43", "Baxi Heating UK", "Potterton", "Profile", "30S", "", "2013", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "29.4", "29.4", "", "", "88.9", "79.9", "", "58.4", "", "2", "", "", "102", "1", "2", "150", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.5", "98.8", "", "", "", "", "96.9"]} -{"pcdb_id": 17231, "brand_name": "Potterton", "model_name": "Profile", "model_qualifier": "30S", "winter_efficiency_pct": 89.9, "summer_efficiency_pct": 80.9, "comparative_hot_water_efficiency_pct": 59.1, "output_kw_max": 29.4, "final_year_of_manufacture": null, "raw": ["017231", "000005", "0", "2014/Jan/27 10:43", "Baxi Heating UK", "Potterton", "Profile", "30S", "", "2013", "current", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "29.4", "29.4", "", "", "89.9", "80.9", "", "59.1", "", "2", "1", "", "102", "1", "2", "150", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.4", "101.0", "", "", "", "", "99.0"]} -{"pcdb_id": 17232, "brand_name": "Vokera", "model_name": "Compact", "model_qualifier": "25A", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 86.6, "comparative_hot_water_efficiency_pct": 72.0, "output_kw_max": 19.5, "final_year_of_manufacture": null, "raw": ["017232", "000011", "0", "2015/Mar/04 16:46", "Vokera", "Vokera", "Compact", "25A", "47 364 17", "2013", "current", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "19.5", "19.5", "", "", "88.5", "86.6", "", "72.0", "", "2", "", "", "104", "1", "2", "123", "4.5", "0", "", "", "", "0", "", "", "", "", "1", "7.315", "0.105", "0.003", "1.17113", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "", "", "", "", "87.8", "98.1", "", "", "", "", "96.2"]} -{"pcdb_id": 17233, "brand_name": "Vokera", "model_name": "Compact", "model_qualifier": "29A", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 86.7, "comparative_hot_water_efficiency_pct": 71.9, "output_kw_max": 24.5, "final_year_of_manufacture": null, "raw": ["017233", "000011", "0", "2015/Mar/04 16:46", "Vokera", "Vokera", "Compact", "29A", "47 364 18", "2013", "current", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "24.5", "24.5", "", "", "88.4", "86.7", "", "71.9", "", "2", "", "", "104", "1", "2", "123", "4.5", "0", "", "", "", "0", "", "", "", "", "1", "7.325", "0.103", "0.003", "1.18793", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "", "", "", "", "88.1", "97.7", "", "", "", "", "95.9"]} -{"pcdb_id": 17234, "brand_name": "Ferroli", "model_name": "T-One", "model_qualifier": "30C HE", "winter_efficiency_pct": 89.6, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 57.0, "output_kw_max": 28.9, "final_year_of_manufacture": 2017, "raw": ["017234", "000097", "0", "2017/Aug/21 13:41", "Ferroli", "Ferroli", "T-One", "30C HE", "", "2013", "2017", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "28.9", "28.9", "", "", "89.6", "81.0", "", "57.0", "", "2", "1", "", "104", "1", "2", "100", "3.2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.4", "100.3", "", "", "", "", "98.4"]} -{"pcdb_id": 17236, "brand_name": "Motan", "model_name": "MKDens 25", "model_qualifier": "", "winter_efficiency_pct": 87.6, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 55.6, "output_kw_max": 24.3, "final_year_of_manufacture": null, "raw": ["017236", "000283", "0", "2014/Jan/31 11:39", "Kober", "Motan", "MKDens 25", "", "", "2012", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.3", "24.3", "", "", "87.6", "79.0", "", "55.6", "", "2", "", "", "104", "1", "2", "175", "0", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.1", "96.1", "", "", "", "", "94.4"]} -{"pcdb_id": 17238, "brand_name": "Motan", "model_name": "MKDens 36", "model_qualifier": "", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 55.7, "output_kw_max": 32.3, "final_year_of_manufacture": null, "raw": ["017238", "000283", "0", "2014/Jan/31 11:39", "Kober", "Motan", "MKDens 36", "", "", "2012", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "32.3", "32.3", "", "", "87.9", "79.3", "", "55.7", "", "2", "", "", "104", "1", "2", "175", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.2", "96.0", "", "", "", "", "94.7"]} -{"pcdb_id": 17239, "brand_name": "Mistral", "model_name": "DKUT 17/33", "model_qualifier": "", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 33.0, "final_year_of_manufacture": null, "raw": ["017239", "000056", "0", "2014/Apr/23 14:08", "Mistral Energy Products Ltd", "Mistral", "DKUT 17/33", "", "", "2013", "current", "4", "1", "1", "1", "0", "", "", "1", "3", "1", "17", "33", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.4", "89.2", "", "", "", "", "88.9"]} -{"pcdb_id": 17240, "brand_name": "Hoval", "model_name": "TopGas (30)", "model_qualifier": "", "winter_efficiency_pct": 87.5, "summer_efficiency_pct": 78.5, "comparative_hot_water_efficiency_pct": 57.3, "output_kw_max": 27.4, "final_year_of_manufacture": null, "raw": ["017240", "000284", "0", "2014/Apr/29 14:07", "Hoval", "Hoval", "TopGas (30)", "", "", "", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "27.4", "27.4", "", "", "87.5", "78.5", "", "57.3", "", "2", "", "", "102", "1", "2", "43", "13", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.3", "95.8", "", "", "", "", "94.2"]} -{"pcdb_id": 17241, "brand_name": "Hoval", "model_name": "TopGas (35)", "model_qualifier": "", "winter_efficiency_pct": 87.3, "summer_efficiency_pct": 78.3, "comparative_hot_water_efficiency_pct": 57.2, "output_kw_max": 31.8, "final_year_of_manufacture": null, "raw": ["017241", "000284", "0", "2014/Apr/29 14:07", "Hoval", "Hoval", "TopGas (35)", "", "", "", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "31.8", "31.8", "", "", "87.3", "78.3", "", "57.2", "", "2", "", "", "102", "1", "2", "62", "13", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "86.9", "95.6", "", "", "", "", "93.9"]} -{"pcdb_id": 17242, "brand_name": "Hoval", "model_name": "TopGas (45)", "model_qualifier": "", "winter_efficiency_pct": 87.3, "summer_efficiency_pct": 78.3, "comparative_hot_water_efficiency_pct": 57.2, "output_kw_max": 41.0, "final_year_of_manufacture": null, "raw": ["017242", "000284", "0", "2014/Apr/29 14:07", "Hoval", "Hoval", "TopGas (45)", "", "", "", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "41.0", "41.0", "", "", "87.3", "78.3", "", "57.2", "", "2", "", "", "102", "1", "2", "66", "13", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "86.9", "95.4", "", "", "", "", "93.8"]} -{"pcdb_id": 17243, "brand_name": "Hoval", "model_name": "TopGas (60)", "model_qualifier": "", "winter_efficiency_pct": 87.3, "summer_efficiency_pct": 78.3, "comparative_hot_water_efficiency_pct": 57.2, "output_kw_max": 55.3, "final_year_of_manufacture": null, "raw": ["017243", "000284", "0", "2014/Apr/29 14:07", "Hoval", "Hoval", "TopGas (60)", "", "", "", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "55.3", "55.3", "", "", "87.3", "78.3", "", "57.2", "", "2", "", "", "102", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "86.9", "95.4", "", "", "", "", "93.8"]} -{"pcdb_id": 17244, "brand_name": "Glow-worm", "model_name": "Glow-Worm", "model_qualifier": "18si", "winter_efficiency_pct": 77.7, "summer_efficiency_pct": 67.6, "comparative_hot_water_efficiency_pct": 49.4, "output_kw_max": 18.4, "final_year_of_manufacture": 2007, "raw": ["017244", "000207", "0", "2014/Apr/16 08:09", "Hepworth Heating", "Glow-worm", "Glow-Worm", "18si", "41-047-61", "2001", "2007", "1", "1", "1", "1", "0", "", "", "1", "2", "1", "8.9", "18.4", "", "", "77.7", "67.6", "", "49.4", "", "2", "", "", "101", "1", "1", "122", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.5", "77.2", "", "", "", "", "78.0"]} -{"pcdb_id": 17245, "brand_name": "Ideal", "model_name": "Classic", "model_qualifier": "30", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 62.3, "output_kw_max": 24.2, "final_year_of_manufacture": null, "raw": ["017245", "000008", "0", "2014/Apr/28 09:04", "Ideal Boilers", "Ideal", "Classic", "30", "47-349-08", "2014", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "88.4", "79.8", "", "62.3", "", "2", "", "", "104", "1", "2", "152", "1", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "", "0035", "", "", "", "", "", "", "", "", "90.0", "96.9", "", "", "", "", "95.6"]} -{"pcdb_id": 17246, "brand_name": "Ideal", "model_name": "Classic", "model_qualifier": "24", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 62.2, "output_kw_max": 24.2, "final_year_of_manufacture": null, "raw": ["017246", "000008", "0", "2014/Apr/28 09:05", "Ideal Boilers", "Ideal", "Classic", "24", "47-349-07", "2014", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "88.3", "79.7", "", "62.2", "", "2", "", "", "104", "1", "2", "146", "1", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "", "0035", "", "", "", "", "", "", "", "", "89.8", "96.9", "", "", "", "", "95.5"]} -{"pcdb_id": 17247, "brand_name": "Vokera", "model_name": "Mynute", "model_qualifier": "i20", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 21.44, "final_year_of_manufacture": null, "raw": ["017247", "000011", "0", "2014/Jul/17 12:28", "Vokera", "Vokera", "Mynute", "i20", "41 094 81", "2013", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "21.44", "21.44", "", "", "88.8", "79.8", "", "58.3", "", "2", "", "", "102", "1", "2", "102", "4.5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "88.4", "98.7", "", "", "", "", "96.8"]} -{"pcdb_id": 17248, "brand_name": "Vokera", "model_name": "Mynute", "model_qualifier": "i30", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 31.77, "final_year_of_manufacture": null, "raw": ["017248", "000011", "0", "2015/Mar/04 16:16", "Vokera", "Vokera", "Mynute", "i30", "41 094 82", "2014", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "31.77", "31.77", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "118", "4.5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "97.8", "", "", "", "", "95.9"]} -{"pcdb_id": 17249, "brand_name": "ROC", "model_name": "LJLGB26-B28CV", "model_qualifier": "", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.4, "comparative_hot_water_efficiency_pct": 56.6, "output_kw_max": 28.0, "final_year_of_manufacture": null, "raw": ["017249", "000285", "0", "2014/Nov/14 10:16", "Guangdong ROC Cool and Heat Equipment Co Ltd", "ROC", "LJLGB26-B28CV", "", "", "2013", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28", "28", "", "", "89.0", "80.4", "", "56.6", "", "2", "", "", "104", "1", "2", "110", "1", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.0", "99.0", "", "", "", "", "97.1"]} -{"pcdb_id": 17250, "brand_name": "ROC", "model_name": "LJLGB26-B28CP", "model_qualifier": "", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.4, "comparative_hot_water_efficiency_pct": 56.6, "output_kw_max": 28.0, "final_year_of_manufacture": null, "raw": ["017250", "000285", "0", "2014/Nov/14 10:16", "Guangdong ROC Cool and Heat Equipment Co Ltd", "ROC", "LJLGB26-B28CP", "", "", "2014", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28", "28", "", "", "89.0", "80.4", "", "56.6", "", "2", "", "", "104", "1", "2", "110", "1", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.0", "99.0", "", "", "", "", "97.1"]} -{"pcdb_id": 17251, "brand_name": "The White Boiler Company", "model_name": "WH 80 (T)", "model_qualifier": "", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 56.4, "output_kw_max": 19.4, "final_year_of_manufacture": null, "raw": ["017251", "000270", "0", "2014/Sep/10 12:09", "The White Boiler Company", "The White Boiler Company", "WH 80 (T)", "", "", "2014", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "19.4", "19.4", "", "", "88.9", "80.3", "", "56.4", "", "2", "1", "", "104", "1", "2", "110", "3", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.8", "98.6", "", "", "", "", "97.0"]} -{"pcdb_id": 17252, "brand_name": "The White Boiler Company", "model_name": "WH 80 (T)", "model_qualifier": "", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 86.6, "comparative_hot_water_efficiency_pct": 76.8, "output_kw_max": 19.5, "final_year_of_manufacture": null, "raw": ["017252", "000270", "0", "2014/Sep/10 12:10", "The White Boiler Company", "The White Boiler Company", "WH 80 (T)", "", "", "2014", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "19.5", "19.5", "", "", "87.9", "86.6", "", "76.8", "", "2", "", "", "104", "1", "2", "110", "3", "0", "", "", "", "0", "", "", "", "", "1", "6.859", "0.134", "0.0104", "0.68941", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "96.5", "", "", "", "", "94.9"]} -{"pcdb_id": 17253, "brand_name": "The White Boiler Company", "model_name": "WH 90 (T)", "model_qualifier": "", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 56.6, "output_kw_max": 23.8, "final_year_of_manufacture": null, "raw": ["017253", "000270", "0", "2014/Sep/10 12:10", "The White Boiler Company", "The White Boiler Company", "WH 90 (T)", "", "", "2014", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "23.8", "23.8", "", "", "89.1", "80.5", "", "56.6", "", "2", "1", "", "104", "1", "2", "160", "3", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.8", "99.3", "", "", "", "", "97.5"]} -{"pcdb_id": 17254, "brand_name": "The White Boiler Company", "model_name": "WH 90 (T)", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 86.6, "comparative_hot_water_efficiency_pct": 69.1, "output_kw_max": 23.8, "final_year_of_manufacture": null, "raw": ["017254", "000270", "0", "2014/Sep/10 12:10", "The White Boiler Company", "The White Boiler Company", "WH 90 (T)", "", "", "2014", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "23.8", "23.8", "", "", "88.1", "86.6", "", "69.1", "", "2", "", "", "104", "1", "2", "160", "3", "0", "", "", "", "0", "", "", "", "", "1", "7.618", "0.129", "0.0065", "1.44231", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "97.1", "", "", "", "", "95.4"]} -{"pcdb_id": 17267, "brand_name": "Firebird", "model_name": "Blue Flame Enviromax Heatpac", "model_qualifier": "26kW", "winter_efficiency_pct": 89.7, "summer_efficiency_pct": 81.9, "comparative_hot_water_efficiency_pct": 59.8, "output_kw_max": 26.0, "final_year_of_manufacture": null, "raw": ["017267", "000047", "0", "2014/Jun/30 08:57", "Firebird Boilers", "Firebird", "Blue Flame Enviromax Heatpac", "26kW", "", "2014", "current", "4", "1", "2", "1", "0", "", "", "2", "2", "1", "26", "26", "", "", "89.7", "81.9", "", "59.8", "", "2", "", "", "201", "1", "1", "38", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "94.2", "97.6", "", "", "", "", "97.0"]} -{"pcdb_id": 17268, "brand_name": "Baxi", "model_name": "Ecoblue 32 System", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 32.0, "final_year_of_manufacture": 2015, "raw": ["017268", "000005", "0", "2015/Aug/06 12:31", "Baxi Heating UK", "Baxi", "Ecoblue 32 System", "", "GC No 41-470-01", "2014", "2015", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "32", "32", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "140", "3.5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "90.0", "96.9", "", "", "", "", "95.6"]} -{"pcdb_id": 17269, "brand_name": "Baxi", "model_name": "Ecoblue 28 System", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 28.0, "final_year_of_manufacture": 2015, "raw": ["017269", "000005", "0", "2015/Aug/06 12:32", "Baxi Heating UK", "Baxi", "Ecoblue 28 System", "", "GC No 41-077-99", "2014", "2015", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "28", "28", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "137", "3.5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "90.0", "96.9", "", "", "", "", "95.6"]} -{"pcdb_id": 17270, "brand_name": "Baxi", "model_name": "Ecoblue 24 System", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 24.0, "final_year_of_manufacture": 2015, "raw": ["017270", "000005", "0", "2015/Aug/06 12:32", "Baxi Heating UK", "Baxi", "Ecoblue 24 System", "", "GC No 41-077-98", "2014", "2015", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24", "24", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "123", "3.5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "90.0", "96.9", "", "", "", "", "95.6"]} -{"pcdb_id": 17271, "brand_name": "Baxi", "model_name": "Ecoblue 18 System", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 18.0, "final_year_of_manufacture": 2015, "raw": ["017271", "000005", "0", "2015/Aug/06 12:33", "Baxi Heating UK", "Baxi", "Ecoblue 18 System", "", "GC No 41-077-97", "2014", "2015", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18", "18", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "125", "3.5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "90.0", "97.0", "", "", "", "", "95.7"]} -{"pcdb_id": 17272, "brand_name": "Baxi", "model_name": "Ecoblue 15 System", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 15.0, "final_year_of_manufacture": 2015, "raw": ["017272", "000005", "0", "2015/Aug/06 12:33", "Baxi Heating UK", "Baxi", "Ecoblue 15 System", "", "GC No 41-077-96", "2014", "2015", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "15", "15", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "108", "3.5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "90.0", "97.0", "", "", "", "", "95.7"]} -{"pcdb_id": 17273, "brand_name": "Baxi", "model_name": "Ecoblue 12 System", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 12.0, "final_year_of_manufacture": 2015, "raw": ["017273", "000005", "0", "2015/Aug/06 12:34", "Baxi Heating UK", "Baxi", "Ecoblue 12 System", "", "GC No 41-077-95", "2014", "2015", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "12", "12", "", "", "88.5", "79.5", "", "58.0", "", "2", "", "", "102", "1", "2", "108", "3.5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "90.0", "97.1", "", "", "", "", "95.8"]} -{"pcdb_id": 17274, "brand_name": "Baxi", "model_name": "Ecoblue Plus 33 Combi", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 77.2, "output_kw_max": 28.0, "final_year_of_manufacture": 2015, "raw": ["017274", "000005", "0", "2015/Aug/06 12:34", "Baxi Heating UK", "Baxi", "Ecoblue Plus 33 Combi", "", "GC No 41-075-86", "2014", "2015", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28", "28", "", "", "88.4", "87.3", "", "77.2", "", "2", "", "", "104", "1", "2", "135", "3.5", "0", "", "", "", "0", "", "", "", "", "1", "6.821", "0.106", "0.0045", "0.74098", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "90.0", "97.0", "", "", "", "", "95.7"]} -{"pcdb_id": 17275, "brand_name": "Baxi", "model_name": "Ecoblue Plus 28 Combi", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 77.3, "output_kw_max": 24.0, "final_year_of_manufacture": 2015, "raw": ["017275", "000005", "0", "2015/Aug/06 12:34", "Baxi Heating UK", "Baxi", "Ecoblue Plus 28 Combi", "", "GC No 41-077-85", "2014", "2015", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "88.4", "87.3", "", "77.3", "", "2", "", "", "104", "1", "2", "130", "3.5", "0", "", "", "", "0", "", "", "", "", "1", "6.813", "0.118", "0.0044", "0.73349", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "90.0", "96.9", "", "", "", "", "95.6"]} -{"pcdb_id": 17276, "brand_name": "Baxi", "model_name": "Ecoblue Plus 24 Combi", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 77.6, "output_kw_max": 20.0, "final_year_of_manufacture": 2015, "raw": ["017276", "000005", "0", "2015/Aug/06 12:35", "Baxi Heating UK", "Baxi", "Ecoblue Plus 24 Combi", "", "GC No 41-075-84", "2014", "2015", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "20", "20", "", "", "88.4", "87.3", "", "77.6", "", "2", "", "", "104", "1", "2", "120", "3.5", "0", "", "", "", "0", "", "", "", "", "1", "6.786", "0.118", "0.0043", "0.70793", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "90.0", "96.9", "", "", "", "", "95.6"]} -{"pcdb_id": 17277, "brand_name": "Baxi", "model_name": "Ecoblue 33 Combi", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 77.2, "output_kw_max": 28.0, "final_year_of_manufacture": 2015, "raw": ["017277", "000005", "0", "2015/Aug/06 12:36", "Baxi Heating UK", "Baxi", "Ecoblue 33 Combi", "", "GC No 41-075-83", "2014", "2015", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28", "28", "", "", "88.4", "87.3", "", "77.2", "", "2", "", "", "104", "1", "2", "135", "3.5", "0", "", "", "", "0", "", "", "", "", "1", "6.821", "0.106", "0.0045", "0.74098", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "90.0", "97.0", "", "", "", "", "95.7"]} -{"pcdb_id": 17278, "brand_name": "Baxi", "model_name": "Ecoblue 28 Combi", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 77.3, "output_kw_max": 24.0, "final_year_of_manufacture": 2015, "raw": ["017278", "000005", "0", "2015/Aug/06 12:36", "Baxi Heating UK", "Baxi", "Ecoblue 28 Combi", "", "GC No 41-075-82", "2014", "2015", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "88.4", "87.3", "", "77.3", "", "2", "", "", "104", "1", "2", "130", "3.5", "0", "", "", "", "0", "", "", "", "", "1", "6.813", "0.118", "0.0044", "0.73349", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "90.0", "96.9", "", "", "", "", "95.6"]} -{"pcdb_id": 17279, "brand_name": "Baxi", "model_name": "Ecoblue 24 Combi", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 77.6, "output_kw_max": 20.0, "final_year_of_manufacture": 2015, "raw": ["017279", "000005", "0", "2015/Aug/06 12:37", "Baxi Heating UK", "Baxi", "Ecoblue 24 Combi", "", "GC No 41-075-81", "2014", "2015", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "20", "20", "", "", "88.4", "87.3", "", "77.6", "", "2", "", "", "104", "1", "2", "120", "3.5", "0", "", "", "", "0", "", "", "", "", "1", "6.786", "0.118", "0.0043", "0.70793", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "90.0", "96.9", "", "", "", "", "95.6"]} -{"pcdb_id": 17280, "brand_name": "Baxi", "model_name": "Ecoblue Advance 33 Combi ERP", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 77.2, "output_kw_max": 28.0, "final_year_of_manufacture": 2015, "raw": ["017280", "000005", "0", "2015/Aug/06 12:37", "Baxi Heating UK", "Baxi", "Ecoblue Advance 33 Combi ERP", "", "GC No 41-075-92", "2014", "2015", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28", "28", "", "", "88.4", "87.3", "", "77.2", "", "2", "", "", "104", "1", "2", "135", "3.5", "0", "", "", "", "0", "", "", "", "", "1", "6.821", "0.106", "0.0045", "0.74098", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "90.0", "97.0", "", "", "", "", "95.7"]} -{"pcdb_id": 17281, "brand_name": "Baxi", "model_name": "Ecoblue Advance 28 Combi ERP", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 77.3, "output_kw_max": 24.0, "final_year_of_manufacture": 2015, "raw": ["017281", "000005", "0", "2015/Aug/06 12:38", "Baxi Heating UK", "Baxi", "Ecoblue Advance 28 Combi ERP", "", "GC No 41-075-91", "2014", "2015", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "88.4", "87.3", "", "77.3", "", "2", "", "", "104", "1", "2", "130", "3.5", "0", "", "", "", "0", "", "", "", "", "1", "6.813", "0.118", "0.0044", "0.73349", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "90.0", "96.9", "", "", "", "", "95.6"]} -{"pcdb_id": 17282, "brand_name": "Baxi", "model_name": "Ecoblue Advance 40 Combi", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 77.8, "output_kw_max": 32.0, "final_year_of_manufacture": 2015, "raw": ["017282", "000005", "0", "2015/Aug/06 12:38", "Baxi Heating UK", "Baxi", "Ecoblue Advance 40 Combi", "", "GC No 41-075-90", "2014", "2015", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "32", "32", "", "", "88.4", "87.3", "", "77.8", "", "2", "", "", "104", "1", "2", "175", "3.5", "0", "", "", "", "0", "", "", "", "", "1", "6.765", "0.111", "0.0036", "0.69163", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.0", "96.9", "", "", "", "", "95.6"]} -{"pcdb_id": 17283, "brand_name": "Baxi", "model_name": "Ecoblue Advance 33 Combi", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 77.2, "output_kw_max": 28.0, "final_year_of_manufacture": 2015, "raw": ["017283", "000005", "0", "2015/Aug/06 12:40", "Baxi Heating UK", "Baxi", "Ecoblue Advance 33 Combi", "", "GC No 41-075-89", "2014", "2015", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28", "28", "", "", "88.4", "87.3", "", "77.2", "", "2", "", "", "104", "1", "2", "135", "3.5", "0", "", "", "", "0", "", "", "", "", "1", "6.821", "0.106", "0.0045", "0.74098", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "90.0", "97.0", "", "", "", "", "95.7"]} -{"pcdb_id": 17284, "brand_name": "Baxi", "model_name": "Ecoblue Advance 28 Combi", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 77.3, "output_kw_max": 24.0, "final_year_of_manufacture": 2015, "raw": ["017284", "000005", "0", "2015/Aug/06 12:40", "Baxi Heating UK", "Baxi", "Ecoblue Advance 28 Combi", "", "GC No 41-075-88", "2014", "2015", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "88.4", "87.3", "", "77.3", "", "2", "", "", "104", "1", "2", "130", "3.5", "0", "", "", "", "0", "", "", "", "", "1", "6.813", "0.118", "0.0044", "0.73349", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "90.0", "96.9", "", "", "", "", "95.6"]} -{"pcdb_id": 17285, "brand_name": "Baxi", "model_name": "Ecoblue Advance 24 Combi", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 77.6, "output_kw_max": 20.0, "final_year_of_manufacture": 2015, "raw": ["017285", "000005", "0", "2015/Aug/06 12:40", "Baxi Heating UK", "Baxi", "Ecoblue Advance 24 Combi", "", "GC No 41-075-87", "2014", "2015", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "20", "20", "", "", "88.4", "87.3", "", "77.6", "", "2", "", "", "104", "1", "2", "120", "3.5", "0", "", "", "", "0", "", "", "", "", "1", "6.786", "0.118", "0.0043", "0.70793", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "90.0", "96.9", "", "", "", "", "95.6"]} -{"pcdb_id": 17286, "brand_name": "Firebird", "model_name": "Enviromax Blue Supreme Popular 26", "model_qualifier": "", "winter_efficiency_pct": 90.6, "summer_efficiency_pct": 82.8, "comparative_hot_water_efficiency_pct": 60.5, "output_kw_max": 26.0, "final_year_of_manufacture": null, "raw": ["017286", "000047", "0", "2015/Nov/13 11:00", "Firebird Heating Solutions Ltd", "Firebird", "Enviromax Blue Supreme Popular 26", "", "", "2014", "current", "4", "1", "2", "1", "0", "", "", "2", "2", "1", "26", "26", "", "", "90.6", "82.8", "", "60.5", "", "2", "", "", "201", "1", "1", "38", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "95.6", "101.4", "", "", "", "", "100.3"]} -{"pcdb_id": 17287, "brand_name": "Firebird", "model_name": "Enviromax Blue Supreme Utility 26", "model_qualifier": "", "winter_efficiency_pct": 90.6, "summer_efficiency_pct": 82.8, "comparative_hot_water_efficiency_pct": 60.5, "output_kw_max": 26.0, "final_year_of_manufacture": null, "raw": ["017287", "000047", "0", "2015/Nov/13 11:00", "Firebird Heating Solutions Ltd", "Firebird", "Enviromax Blue Supreme Utility 26", "", "", "2014", "current", "4", "1", "1", "1", "0", "", "", "2", "2", "1", "26", "26", "", "", "90.6", "82.8", "", "60.5", "", "2", "", "", "201", "1", "1", "38", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "95.6", "101.4", "", "", "", "", "100.3"]} -{"pcdb_id": 17289, "brand_name": "Firebird", "model_name": "Enviromax Blue Supreme Heatpac 26", "model_qualifier": "", "winter_efficiency_pct": 90.6, "summer_efficiency_pct": 82.8, "comparative_hot_water_efficiency_pct": 60.5, "output_kw_max": 26.0, "final_year_of_manufacture": null, "raw": ["017289", "000047", "0", "2015/Nov/13 10:59", "firebird Heating Solutions Ltd", "Firebird", "Enviromax Blue Supreme Heatpac 26", "", "", "2014", "current", "4", "1", "2", "1", "0", "", "", "2", "2", "1", "26", "26", "", "", "90.6", "82.8", "", "60.5", "", "2", "", "", "201", "1", "1", "38", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "95.6", "101.4", "", "", "", "", "100.3"]} -{"pcdb_id": 17290, "brand_name": "Firebird", "model_name": "Enviromax Blue Supreme Popular 20", "model_qualifier": "", "winter_efficiency_pct": 90.6, "summer_efficiency_pct": 82.8, "comparative_hot_water_efficiency_pct": 60.5, "output_kw_max": 20.0, "final_year_of_manufacture": null, "raw": ["017290", "000047", "0", "2015/Nov/13 10:59", "firebird Heating Solutions Ltd", "Firebird", "Enviromax Blue Supreme Popular 20", "", "", "2014", "current", "4", "1", "2", "1", "0", "", "", "2", "2", "1", "20", "20", "", "", "90.6", "82.8", "", "60.5", "", "2", "", "", "201", "1", "1", "38", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "95.7", "101.3", "", "", "", "", "100.2"]} -{"pcdb_id": 17291, "brand_name": "Firebird", "model_name": "Enviromax Blue Supreme Heatpac 20", "model_qualifier": "", "winter_efficiency_pct": 90.6, "summer_efficiency_pct": 82.8, "comparative_hot_water_efficiency_pct": 60.5, "output_kw_max": 20.0, "final_year_of_manufacture": null, "raw": ["017291", "000047", "0", "2015/Nov/13 10:59", "firebird Heating Solutions Ltd", "Firebird", "Enviromax Blue Supreme Heatpac 20", "", "", "2014", "current", "4", "1", "2", "1", "0", "", "", "2", "2", "1", "20", "20", "", "", "90.6", "82.8", "", "60.5", "", "2", "", "", "201", "1", "1", "38", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "95.7", "101.3", "", "", "", "", "100.2"]} -{"pcdb_id": 17292, "brand_name": "Firebird", "model_name": "Enviromax Blue Supreme Utility 20", "model_qualifier": "", "winter_efficiency_pct": 90.6, "summer_efficiency_pct": 82.8, "comparative_hot_water_efficiency_pct": 60.5, "output_kw_max": 20.0, "final_year_of_manufacture": null, "raw": ["017292", "000047", "0", "2015/Nov/13 10:58", "firebird Heating Solutions Ltd", "Firebird", "Enviromax Blue Supreme Utility 20", "", "", "2014", "current", "4", "1", "1", "1", "0", "", "", "2", "2", "1", "20", "20", "", "", "90.6", "82.8", "", "60.5", "", "2", "", "", "201", "1", "1", "38", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "95.7", "101.3", "", "", "", "", "100.2"]} -{"pcdb_id": 17293, "brand_name": "Firebird", "model_name": "Enviromax Amber Supreme Popular 26", "model_qualifier": "", "winter_efficiency_pct": 90.4, "summer_efficiency_pct": 82.6, "comparative_hot_water_efficiency_pct": 60.4, "output_kw_max": 25.0, "final_year_of_manufacture": null, "raw": ["017293", "000047", "0", "2015/Nov/13 10:58", "firebird Heating Solutions Ltd", "Firebird", "Enviromax Amber Supreme Popular 26", "", "", "2014", "current", "4", "1", "2", "1", "0", "", "", "2", "2", "1", "25.5", "25", "", "", "90.4", "82.6", "", "60.4", "", "2", "", "", "201", "1", "1", "38", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "94.7", "100.7", "", "", "", "", "99.6"]} -{"pcdb_id": 17294, "brand_name": "Firebird", "model_name": "Enviromax Amber Supreme Utility 26", "model_qualifier": "", "winter_efficiency_pct": 90.4, "summer_efficiency_pct": 82.6, "comparative_hot_water_efficiency_pct": 60.4, "output_kw_max": 25.5, "final_year_of_manufacture": null, "raw": ["017294", "000047", "0", "2015/Nov/13 10:58", "firebird Heating Solutions Ltd", "Firebird", "Enviromax Amber Supreme Utility 26", "", "", "2014", "current", "4", "1", "1", "1", "0", "", "", "2", "2", "1", "25.5", "25.5", "", "", "90.4", "82.6", "", "60.4", "", "2", "", "", "201", "1", "1", "38", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "94.7", "100.7", "", "", "", "", "99.6"]} -{"pcdb_id": 17295, "brand_name": "Firebird", "model_name": "Enviromax Amber Supreme Heatpac 26", "model_qualifier": "", "winter_efficiency_pct": 90.4, "summer_efficiency_pct": 82.6, "comparative_hot_water_efficiency_pct": 60.4, "output_kw_max": 25.5, "final_year_of_manufacture": null, "raw": ["017295", "000047", "0", "2015/Nov/13 10:57", "firebird Heating Solutions Ltd", "Firebird", "Enviromax Amber Supreme Heatpac 26", "", "", "2014", "current", "4", "1", "2", "1", "0", "", "", "2", "2", "1", "25.5", "25.5", "", "", "90.4", "82.6", "", "60.4", "", "2", "", "", "201", "1", "1", "38", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "94.7", "100.7", "", "", "", "", "99.6"]} -{"pcdb_id": 17296, "brand_name": "Baxi", "model_name": "Precision +", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 30.0, "final_year_of_manufacture": 2015, "raw": ["017296", "000005", "0", "2015/Aug/06 12:41", "Baxi Heating UK", "Baxi", "Precision +", "", "41-470-12", "2014", "2015", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "12", "30", "", "", "88.5", "79.5", "", "58.0", "", "2", "", "", "102", "1", "2", "44", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "98.0", "", "", "", "", "96.1"]} -{"pcdb_id": 17297, "brand_name": "Baxi", "model_name": "EcoBlue Advance Heat", "model_qualifier": "30", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 30.0, "final_year_of_manufacture": 2015, "raw": ["017297", "000005", "0", "2015/Aug/06 12:42", "Baxi Heating UK", "Baxi", "EcoBlue Advance Heat", "30", "", "2014", "2015", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "30", "30", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "44", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.5", "98.0", "", "", "", "", "96.0"]} -{"pcdb_id": 17298, "brand_name": "Baxi", "model_name": "EcoBlue Advance Heat", "model_qualifier": "25", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 25.0, "final_year_of_manufacture": 2015, "raw": ["017298", "000005", "0", "2015/Aug/06 12:42", "Baxi Heating UK", "Baxi", "EcoBlue Advance Heat", "25", "", "2014", "2015", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "25", "25", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "33", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.7", "98.0", "", "", "", "", "96.1"]} -{"pcdb_id": 17299, "brand_name": "Baxi", "model_name": "EcoBlue Advance Heat", "model_qualifier": "19", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 19.0, "final_year_of_manufacture": 2015, "raw": ["017299", "000005", "0", "2015/Aug/06 12:43", "Baxi Heating UK", "Baxi", "EcoBlue Advance Heat", "19", "", "2014", "2015", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "19", "19", "", "", "88.5", "79.5", "", "58.0", "", "2", "", "", "102", "1", "2", "23", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "98.0", "", "", "", "", "96.1"]} -{"pcdb_id": 17300, "brand_name": "Baxi", "model_name": "EcoBlue Advance Heat", "model_qualifier": "16", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 16.0, "final_year_of_manufacture": 2015, "raw": ["017300", "000005", "0", "2015/Aug/06 12:43", "Baxi Heating UK", "Baxi", "EcoBlue Advance Heat", "16", "", "2014", "2015", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "16", "16", "", "", "88.5", "79.5", "", "58.1", "", "2", "", "", "102", "1", "2", "20", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "98.0", "", "", "", "", "96.1"]} -{"pcdb_id": 17301, "brand_name": "Baxi", "model_name": "EcoBlue Advance Heat", "model_qualifier": "13", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 13.0, "final_year_of_manufacture": 2015, "raw": ["017301", "000005", "0", "2015/Aug/06 12:44", "Baxi Heating UK", "Baxi", "EcoBlue Advance Heat", "13", "41-470-07", "2014", "2015", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "13", "13", "", "", "88.5", "79.5", "", "58.1", "", "2", "", "", "102", "1", "2", "17", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "98.0", "", "", "", "", "96.1"]} -{"pcdb_id": 17302, "brand_name": "Baxi", "model_name": "EcoBlue Heat", "model_qualifier": "12", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 13.0, "final_year_of_manufacture": 2015, "raw": ["017302", "000005", "0", "2015/Aug/06 12:44", "Baxi Heating UK", "Baxi", "EcoBlue Heat", "12", "41-470-02", "2014", "2015", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "13", "13", "", "", "88.5", "79.5", "", "58.1", "", "2", "", "", "102", "1", "2", "17", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "98.0", "", "", "", "", "96.1"]} -{"pcdb_id": 17303, "brand_name": "Baxi", "model_name": "EcoBlue Heat", "model_qualifier": "18", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 19.0, "final_year_of_manufacture": 2015, "raw": ["017303", "000005", "0", "2015/Aug/06 12:44", "Baxi Heating UK", "Baxi", "EcoBlue Heat", "18", "", "2014", "2015", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "19", "19", "", "", "88.5", "79.5", "", "58.0", "", "2", "", "", "102", "1", "2", "23", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "98.0", "", "", "", "", "96.1"]} -{"pcdb_id": 17304, "brand_name": "Baxi", "model_name": "EcoBlue Heat", "model_qualifier": "21", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 21.0, "final_year_of_manufacture": 2015, "raw": ["017304", "000005", "0", "2015/Aug/06 12:45", "Baxi Heating UK", "Baxi", "EcoBlue Heat", "21", "", "2014", "2015", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "21", "21", "", "", "88.5", "79.5", "", "58.0", "", "2", "", "", "102", "1", "2", "25", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "98.0", "", "", "", "", "96.1"]} -{"pcdb_id": 17305, "brand_name": "Baxi", "model_name": "EcoBlue Heat", "model_qualifier": "24", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 25.0, "final_year_of_manufacture": 2015, "raw": ["017305", "000005", "0", "2015/Aug/06 12:45", "Baxi Heating UK", "Baxi", "EcoBlue Heat", "24", "", "2014", "2015", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "25", "25", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "33", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.7", "98.0", "", "", "", "", "96.1"]} -{"pcdb_id": 17306, "brand_name": "Baxi", "model_name": "EcoBlue Heat", "model_qualifier": "15", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 16.0, "final_year_of_manufacture": 2015, "raw": ["017306", "000005", "0", "2015/Aug/06 12:46", "Baxi Heating UK", "Baxi", "EcoBlue Heat", "15", "", "2014", "2015", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "16", "16", "", "", "88.5", "79.5", "", "58.1", "", "2", "", "", "102", "1", "2", "20", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "98.0", "", "", "", "", "96.1"]} -{"pcdb_id": 17307, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "30", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 86.6, "comparative_hot_water_efficiency_pct": 69.2, "output_kw_max": 20.2, "final_year_of_manufacture": 2015, "raw": ["017307", "000035", "0", "2020/Sep/08 10:43", "Bosch Thermotechnology", "Worcester", "Greenstar", "30", "47-406-64", "2014", "2015", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "20.2", "20.2", "", "", "88.0", "86.6", "", "69.2", "", "2", "", "", "104", "1", "2", "130", "9", "0", "", "", "", "0", "", "", "", "", "1", "7.615", "0.1348", "0.0047", "1.44724", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "96.9", "", "", "", "", "95.1"]} -{"pcdb_id": 17309, "brand_name": "Worcester", "model_name": "535 Compact NG", "model_qualifier": "", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 87.9, "comparative_hot_water_efficiency_pct": 76.5, "output_kw_max": 24.0, "final_year_of_manufacture": 2015, "raw": ["017309", "000035", "0", "2020/Apr/09 16:20", "Bosch Thermotechnology", "Worcester", "535 Compact NG", "", "47-406-59", "2014", "2015", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "89.2", "87.9", "", "76.5", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "", "0", "", "", "", "", "2", "6.88", "0.092", "0.0015", "0.78638", "12.834", "0.114", "0.0008", "0.72553", "0.00001", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.8", "99.6", "", "", "", "", "97.5"]} -{"pcdb_id": 17310, "brand_name": "Worcester", "model_name": "533 Compact NG", "model_qualifier": "", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 88.2, "comparative_hot_water_efficiency_pct": 76.3, "output_kw_max": 24.0, "final_year_of_manufacture": 2015, "raw": ["017310", "000035", "0", "2020/Sep/08 10:43", "Bosch Thermotechnology", "Worcester", "533 Compact NG", "", "47-406-58", "2014", "2015", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "89.2", "88.2", "", "76.3", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "", "0", "", "", "", "", "2", "6.899", "0.091", "0.0015", "0.80471", "12.831", "0.113", "0.0008", "0.76468", "0.00001", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.8", "99.6", "", "", "", "", "97.5"]} -{"pcdb_id": 17311, "brand_name": "Vokera", "model_name": "Unica", "model_qualifier": "i36", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 86.6, "comparative_hot_water_efficiency_pct": 71.3, "output_kw_max": 29.5, "final_year_of_manufacture": null, "raw": ["017311", "000011", "0", "2016/Sep/21 11:27", "Vokera", "Vokera", "Unica", "i36", "4736416", "2014", "current", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "29.5", "29.5", "", "", "88.6", "86.6", "", "71.3", "", "2", "", "", "104", "1", "2", "136", "4.9", "0", "", "", "", "0", "", "", "", "", "1", "7.389", "0.161", "0.002", "1.24813", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "", "", "", "", "87.8", "98.4", "", "", "", "", "96.4"]} -{"pcdb_id": 17312, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "30 CDi Classic System", "winter_efficiency_pct": 89.5, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 58.8, "output_kw_max": 30.0, "final_year_of_manufacture": 2015, "raw": ["017312", "000035", "0", "2020/Sep/08 10:43", "Bosch Thermotechnology", "Worcester", "Greenstar", "30 CDi Classic System", "41-406-38", "2014", "2015", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "30.0", "30.0", "", "", "89.5", "80.5", "", "58.8", "", "2", "1", "", "102", "1", "2", "58", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0305", "", "", "", "", "", "", "", "", "90.0", "100.2", "", "", "", "", "98.3"]} -{"pcdb_id": 17313, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "30 CDi Classic System", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 30.0, "final_year_of_manufacture": 2015, "raw": ["017313", "000035", "0", "2020/Sep/08 10:43", "Bosch Thermotechnology", "Worcester", "Greenstar", "30 CDi Classic System", "41-406-37", "2014", "2015", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "30.0", "30.0", "", "", "88.5", "79.5", "", "58.1", "", "2", "", "", "102", "1", "2", "58", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0305", "", "", "", "", "", "", "", "", "88.0", "98.0", "", "", "", "", "96.1"]} -{"pcdb_id": 17314, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "40 CDi Classic Regular", "winter_efficiency_pct": 89.5, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 58.8, "output_kw_max": 40.8, "final_year_of_manufacture": 2015, "raw": ["017314", "000035", "0", "2020/Sep/08 10:43", "Bosch Thermotechnology", "Worcester", "Greenstar", "40 CDi Classic Regular", "41-406-36", "2014", "2015", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "40.8", "40.8", "", "", "89.5", "80.5", "", "58.8", "", "2", "1", "", "102", "1", "2", "90", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.8", "100.3", "", "", "", "", "98.3"]} -{"pcdb_id": 17315, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "40 CDi Classic Regular", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 40.8, "final_year_of_manufacture": 2015, "raw": ["017315", "000035", "0", "2020/Sep/08 10:43", "Bosch Thermotechnology", "Worcester", "Greenstar", "40 CDi Classic Regular", "41-406-35", "2014", "2015", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "40.8", "40.8", "", "", "88.5", "79.5", "", "58.1", "", "2", "", "", "102", "1", "2", "90", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "98.1", "", "", "", "", "96.2"]} -{"pcdb_id": 17316, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "30 CDi Classic Regular", "winter_efficiency_pct": 89.5, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 58.8, "output_kw_max": 30.0, "final_year_of_manufacture": 2015, "raw": ["017316", "000035", "0", "2020/Sep/08 10:43", "Bosch Thermotechnology", "Worcester", "Greenstar", "30 CDi Classic Regular", "41-406-34", "2014", "2015", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "30.0", "30.0", "", "", "89.5", "80.5", "", "58.8", "", "2", "1", "", "102", "1", "2", "58", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.0", "100.2", "", "", "", "", "98.3"]} -{"pcdb_id": 17317, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "30 CDi Classic Regular", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 30.0, "final_year_of_manufacture": 2015, "raw": ["017317", "000035", "0", "2020/Sep/08 10:43", "Bosch Thermotechnology", "Worcester", "Greenstar", "30 CDi Classic Regular", "41-406-33", "2014", "2015", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "30", "30", "", "", "88.5", "79.5", "", "58.1", "", "2", "", "", "102", "1", "2", "58", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "98.0", "", "", "", "", "96.1"]} -{"pcdb_id": 17318, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "35 CDi Classic System", "winter_efficiency_pct": 89.5, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 58.8, "output_kw_max": 34.0, "final_year_of_manufacture": 2015, "raw": ["017318", "000035", "0", "2020/Sep/08 10:43", "Bosch Thermotechnology", "Worcester", "Greenstar", "35 CDi Classic System", "41-406-40", "2014", "2015", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "34", "34", "", "", "89.5", "80.5", "", "58.8", "", "2", "1", "", "102", "1", "2", "60", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0305", "", "", "", "", "", "", "", "", "89.8", "100.3", "", "", "", "", "98.3"]} -{"pcdb_id": 17320, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "35 CDi Classic System", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 34.0, "final_year_of_manufacture": 2015, "raw": ["017320", "000035", "0", "2020/Sep/08 10:44", "Bosch Thermotechnology", "Worcester", "Greenstar", "35 CDi Classic System", "41-406-39", "2014", "2015", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "34", "34", "", "", "88.5", "79.5", "", "58.1", "", "2", "", "", "102", "1", "2", "60", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0305", "", "", "", "", "", "", "", "", "87.8", "98.1", "", "", "", "", "96.2"]} -{"pcdb_id": 17321, "brand_name": "Saturn", "model_name": "NHC 25 E", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 80.9, "comparative_hot_water_efficiency_pct": 56.9, "output_kw_max": 25.129, "final_year_of_manufacture": null, "raw": ["017321", "000268", "0", "2014/Oct/17 09:16", "KD Navien", "Saturn", "NHC 25 E", "", "", "2006", "current", "4", "1", "2", "2", "0", "", "", "2", "1", "2", "25.129", "25.129", "", "", "88.3", "80.9", "", "56.9", "", "2", "", "", "202", "1", "1", "143", "115", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "93.6", "94.4", "", "", "", "", "94.3"]} -{"pcdb_id": 17322, "brand_name": "Saturn", "model_name": "NHC 30 E", "model_qualifier": "", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 56.9, "output_kw_max": 30.0, "final_year_of_manufacture": null, "raw": ["017322", "000268", "0", "2014/Nov/26 08:51", "KD Navien", "Saturn", "NHC 30 E", "", "", "2006", "current", "4", "1", "2", "2", "0", "", "", "2", "1", "2", "30", "30", "", "", "88.2", "80.8", "", "56.9", "", "2", "", "", "202", "1", "1", "150", "121", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "93.6", "94.3", "", "", "", "", "94.1"]} -{"pcdb_id": 17323, "brand_name": "Saturn", "model_name": "NHC 41 E", "model_qualifier": "", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 56.8, "output_kw_max": 36.849, "final_year_of_manufacture": null, "raw": ["017323", "000268", "0", "2014/Oct/17 09:16", "KD Navien", "Saturn", "NHC 41 E", "", "", "2006", "current", "4", "1", "2", "2", "0", "", "", "2", "1", "2", "36.849", "36.849", "", "", "88.2", "80.8", "", "56.8", "", "2", "", "", "202", "1", "1", "199", "140", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "93.6", "94.1", "", "", "", "", "94.0"]} -{"pcdb_id": 17324, "brand_name": "Baxi", "model_name": "MainEco Combi", "model_qualifier": "35", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 56.1, "output_kw_max": 29.2, "final_year_of_manufacture": 2015, "raw": ["017324", "000005", "0", "2015/Aug/06 12:46", "Baxi Heating UK", "Baxi", "MainEco Combi", "35", "", "2014", "2015", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "29.2", "29.2", "", "", "88.4", "79.8", "", "56.1", "", "2", "", "", "104", "1", "2", "145", "3", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.6", "98.0", "", "", "", "", "96.0"]} -{"pcdb_id": 17325, "brand_name": "Baxi", "model_name": "MainEco Combi", "model_qualifier": "24", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 56.3, "output_kw_max": 19.5, "final_year_of_manufacture": 2015, "raw": ["017325", "000005", "0", "2015/Aug/06 12:47", "Baxi Heating UK", "Baxi", "MainEco Combi", "24", "", "2014", "2015", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "19.5", "19.5", "", "", "88.7", "80.1", "", "56.3", "", "2", "", "", "104", "1", "2", "105", "3", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.4", "98.5", "", "", "", "", "96.6"]} -{"pcdb_id": 17326, "brand_name": "Baxi", "model_name": "MainEco Combi", "model_qualifier": "28", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 56.3, "output_kw_max": 23.4, "final_year_of_manufacture": 2015, "raw": ["017326", "000005", "0", "2015/Aug/06 12:48", "Baxi Heating UK", "Baxi", "MainEco Combi", "28", "", "2014", "2015", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "23.4", "23.4", "", "", "88.6", "80.0", "", "56.3", "", "2", "", "", "104", "1", "2", "117", "3", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "98.4", "", "", "", "", "96.4"]} -{"pcdb_id": 17327, "brand_name": "Baxi", "model_name": "MainEco Heat", "model_qualifier": "15", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 16.0, "final_year_of_manufacture": 2015, "raw": ["017327", "000005", "0", "2015/Aug/06 12:48", "Baxi Heating UK", "Baxi", "MainEco Heat", "15", "", "2014", "2015", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "16", "16", "", "", "88.5", "79.5", "", "58.1", "", "2", "", "", "102", "1", "2", "20", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "98.0", "", "", "", "", "96.1"]} -{"pcdb_id": 17328, "brand_name": "Baxi", "model_name": "MainEco Heat", "model_qualifier": "18", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 19.0, "final_year_of_manufacture": 2015, "raw": ["017328", "000005", "0", "2015/Aug/06 12:48", "Baxi Heating UK", "Baxi", "MainEco Heat", "18", "", "2014", "2015", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "19", "19", "", "", "88.5", "79.5", "", "58.0", "", "2", "", "", "102", "1", "2", "23", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "98.0", "", "", "", "", "96.1"]} -{"pcdb_id": 17329, "brand_name": "Baxi", "model_name": "MainEco Heat", "model_qualifier": "24", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 25.0, "final_year_of_manufacture": 2015, "raw": ["017329", "000005", "0", "2015/Aug/06 12:49", "Baxi Heating UK", "Baxi", "MainEco Heat", "24", "", "2014", "2015", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "25", "25", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "33", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.7", "98.0", "", "", "", "", "96.1"]} -{"pcdb_id": 17330, "brand_name": "Baxi", "model_name": "MainEco System", "model_qualifier": "24", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 23.4, "final_year_of_manufacture": 2015, "raw": ["017330", "000005", "0", "2015/Aug/06 12:49", "Baxi Heating UK", "Baxi", "MainEco System", "24", "", "2014", "2015", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "23.4", "23.4", "", "", "88.6", "79.6", "", "58.2", "", "2", "", "", "102", "1", "2", "103", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "98.4", "", "", "", "", "96.4"]} -{"pcdb_id": 17331, "brand_name": "Baxi", "model_name": "MainEco System", "model_qualifier": "18", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 17.7, "final_year_of_manufacture": 2015, "raw": ["017331", "000005", "0", "2015/Aug/06 12:50", "Baxi Heating UK", "Baxi", "MainEco System", "18", "", "2014", "2015", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "17.7", "17.7", "", "", "88.7", "79.7", "", "58.2", "", "2", "", "", "102", "1", "2", "92", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.5", "98.5", "", "", "", "", "96.6"]} -{"pcdb_id": 17332, "brand_name": "Sime", "model_name": "Murelle Pro HE", "model_qualifier": "25", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 86.9, "comparative_hot_water_efficiency_pct": 67.6, "output_kw_max": 21.4, "final_year_of_manufacture": 2018, "raw": ["017332", "000213", "0", "2018/Jul/11 10:08", "Fonderie Sime S.p.A.", "Sime", "Murelle Pro HE", "25", "", "2014", "2018", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "21.4", "21.4", "", "", "88.0", "86.9", "", "67.6", "", "2", "", "", "104", "1", "2", "105", "", "0", "", "", "", "0", "", "", "", "", "1", "7.79", "0.129", "0.0061", "1.63545", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.7", "96.4", "", "", "", "", "95.0"]} -{"pcdb_id": 17333, "brand_name": "Sime", "model_name": "Murelle Pro HE", "model_qualifier": "30", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 86.9, "comparative_hot_water_efficiency_pct": 66.4, "output_kw_max": 29.5, "final_year_of_manufacture": 2018, "raw": ["017333", "000213", "0", "2018/Jul/11 10:32", "Fonderie Sime S.p.A.", "Sime", "Murelle Pro HE", "30", "", "2014", "2018", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "29.5", "29.5", "", "", "87.9", "86.9", "", "66.4", "", "2", "", "", "104", "1", "2", "135", "", "0", "", "", "", "0", "", "", "", "", "1", "7.93", "0.13", "0.0052", "1.77051", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.6", "96.4", "", "", "", "", "94.9"]} -{"pcdb_id": 17334, "brand_name": "Sime", "model_name": "Murelle Pro HE", "model_qualifier": "20 R", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 19.7, "final_year_of_manufacture": 2018, "raw": ["017334", "000213", "0", "2018/Jul/11 10:06", "Fonderie Sime S.p.A.", "Sime", "Murelle Pro HE", "20 R", "", "2014", "2018", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "19.7", "19.7", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "105", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.7", "96.4", "", "", "", "", "95.0"]} -{"pcdb_id": 17335, "brand_name": "Sime", "model_name": "Murelle Pro HE", "model_qualifier": "25", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.4, "comparative_hot_water_efficiency_pct": 56.5, "output_kw_max": 21.4, "final_year_of_manufacture": 2018, "raw": ["017335", "000213", "0", "2018/Jul/11 10:09", "Fonderie Sime S.p.A.", "Sime", "Murelle Pro HE", "25", "", "2014", "2018", "2", "2", "1", "2", "0", "", "", "2", "3", "2", "21.4", "21.4", "", "", "89.0", "80.4", "", "56.5", "", "2", "1", "", "104", "1", "2", "105", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.7", "98.5", "", "", "", "", "97.1"]} -{"pcdb_id": 17336, "brand_name": "Sime", "model_name": "Murelle Pro HE", "model_qualifier": "30", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 56.5, "output_kw_max": 23.6, "final_year_of_manufacture": 2018, "raw": ["017336", "000213", "0", "2018/Jul/11 10:32", "Fonderie Sime S.p.A.", "Sime", "Murelle Pro HE", "30", "", "2014", "2018", "2", "2", "1", "2", "0", "", "", "2", "3", "2", "23.6", "23.6", "", "", "88.9", "80.3", "", "56.5", "", "2", "1", "", "104", "1", "2", "114", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.5", "98.5", "", "", "", "", "97.0"]} -{"pcdb_id": 17337, "brand_name": "Sime", "model_name": "Murelle Pro HE", "model_qualifier": "20 R", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 19.7, "final_year_of_manufacture": 2018, "raw": ["017337", "000213", "0", "2018/Jul/11 10:06", "Fonderie Sime S.p.A.", "Sime", "Murelle Pro HE", "20 R", "", "2014", "2018", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "19.7", "19.7", "", "", "89.0", "80.0", "", "58.4", "", "2", "1", "", "102", "1", "2", "105", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.7", "98.5", "", "", "", "", "97.1"]} -{"pcdb_id": 17338, "brand_name": "Sime", "model_name": "Murelle Pro HE", "model_qualifier": "30 R", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 78.9, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 29.5, "final_year_of_manufacture": 2018, "raw": ["017338", "000213", "0", "2018/Jul/11 10:35", "Fonderie Sime S.p.A.", "Sime", "Murelle Pro HE", "30 R", "", "2014", "2018", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "29.5", "29.5", "", "", "87.9", "78.9", "", "57.7", "", "2", "", "", "102", "1", "2", "135", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.6", "96.4", "", "", "", "", "94.9"]} -{"pcdb_id": 17339, "brand_name": "Sime", "model_name": "Murelle Pro HE", "model_qualifier": "30 R", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 29.5, "final_year_of_manufacture": 2018, "raw": ["017339", "000213", "0", "2018/Jul/11 10:36", "Fonderie Sime S.p.A.", "Sime", "Murelle Pro HE", "30 R", "", "2014", "2018", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "29.5", "29.5", "", "", "88.9", "79.9", "", "58.4", "", "2", "1", "", "102", "1", "2", "135", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.5", "98.5", "", "", "", "", "97.0"]} -{"pcdb_id": 17340, "brand_name": "Sime", "model_name": "Murelle Pro HE", "model_qualifier": "25 LPG", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.4, "comparative_hot_water_efficiency_pct": 56.5, "output_kw_max": 19.7, "final_year_of_manufacture": 2018, "raw": ["017340", "000213", "0", "2018/Jul/11 10:12", "Fonderie Sime S.p.A.", "Sime", "Murelle Pro HE", "25 LPG", "", "2014", "2018", "2", "2", "1", "2", "0", "", "", "2", "3", "2", "19.7", "19.7", "", "", "89.0", "80.4", "", "56.5", "", "2", "1", "", "104", "1", "2", "105", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.7", "98.5", "", "", "", "", "97.1"]} -{"pcdb_id": 17341, "brand_name": "Sime", "model_name": "Murelle Pro HE", "model_qualifier": "25 HO", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 78.9, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 23.6, "final_year_of_manufacture": 2018, "raw": ["017341", "000213", "0", "2018/Jul/11 10:10", "Fonderie Sime S.p.A.", "Sime", "Murelle Pro HE", "25 HO", "", "2014", "2018", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "23.6", "23.6", "", "", "87.9", "78.9", "", "57.7", "", "2", "", "", "102", "1", "2", "35", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.6", "96.4", "", "", "", "", "94.9"]} -{"pcdb_id": 17342, "brand_name": "Sime", "model_name": "Murelle Pro HE", "model_qualifier": "25 HO", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 23.6, "final_year_of_manufacture": 2018, "raw": ["017342", "000213", "0", "2018/Jul/11 10:10", "Fonderie Sime S.p.A.", "Sime", "Murelle Pro HE", "25 HO", "", "2014", "2018", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "23.6", "23.6", "", "", "88.9", "79.9", "", "58.4", "", "2", "1", "", "102", "1", "2", "35", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.5", "98.5", "", "", "", "", "97.0"]} -{"pcdb_id": 17343, "brand_name": "Sime", "model_name": "Murelle Advanced HE", "model_qualifier": "30", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 86.9, "comparative_hot_water_efficiency_pct": 68.0, "output_kw_max": 23.6, "final_year_of_manufacture": 2018, "raw": ["017343", "000213", "0", "2018/Jul/11 09:47", "Fonderie Sime S.p.A.", "Sime", "Murelle Advanced HE", "30", "", "2014", "2018", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "23.6", "23.6", "", "", "87.9", "86.9", "", "68.0", "", "2", "", "", "104", "1", "2", "114", "", "0", "", "", "", "0", "", "", "", "", "1", "7.74", "0.132", "0.0047", "1.58981", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.6", "96.4", "", "", "", "", "94.9"]} -{"pcdb_id": 17344, "brand_name": "Sime", "model_name": "Murelle Advanced HE", "model_qualifier": "30", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 56.5, "output_kw_max": 23.6, "final_year_of_manufacture": 2018, "raw": ["017344", "000213", "0", "2018/Jul/11 09:47", "Fonderie Sime S.p.A.", "Sime", "Murelle Advanced HE", "30", "", "2014", "2018", "2", "2", "1", "2", "0", "", "", "2", "3", "2", "23.6", "23.6", "", "", "88.9", "80.3", "", "56.5", "", "2", "1", "", "104", "1", "2", "114", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.5", "98.5", "", "", "", "", "97.0"]} -{"pcdb_id": 17345, "brand_name": "Sime", "model_name": "Murelle Advanced HE", "model_qualifier": "40", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 87.0, "comparative_hot_water_efficiency_pct": 60.6, "output_kw_max": 34.5, "final_year_of_manufacture": 2018, "raw": ["017345", "000213", "0", "2018/Jul/11 09:48", "Fonderie Sime S.p.A.", "Sime", "Murelle Advanced HE", "40", "", "2014", "2018", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "34.5", "34.5", "", "", "88.0", "87.0", "", "60.6", "", "2", "", "", "104", "1", "2", "135", "", "0", "", "", "", "0", "", "", "", "", "1", "8.69", "0.124", "0.0045", "2.51603", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.8", "96.4", "", "", "", "", "95.0"]} -{"pcdb_id": 17346, "brand_name": "Sime", "model_name": "Murelle Advanced HE", "model_qualifier": "40", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.4, "comparative_hot_water_efficiency_pct": 56.5, "output_kw_max": 34.5, "final_year_of_manufacture": 2018, "raw": ["017346", "000213", "0", "2018/Jul/11 09:49", "Fonderie Sime S.p.A.", "Sime", "Murelle Advanced HE", "40", "", "2014", "2018", "2", "2", "1", "2", "0", "", "", "2", "3", "2", "34.5", "34.5", "", "", "89.0", "80.4", "", "56.5", "", "2", "1", "", "104", "1", "2", "135", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.8", "98.5", "", "", "", "", "97.1"]} -{"pcdb_id": 17347, "brand_name": "Sime", "model_name": "Murelle Elite HE", "model_qualifier": "25", "winter_efficiency_pct": 87.8, "summer_efficiency_pct": 86.6, "comparative_hot_water_efficiency_pct": 68.9, "output_kw_max": 23.9, "final_year_of_manufacture": 2018, "raw": ["017347", "000213", "0", "2018/Jul/11 09:53", "Fonderie Sime S.p.A.", "Sime", "Murelle Elite HE", "25", "", "2014", "2018", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "23.9", "23.9", "", "", "87.8", "86.6", "", "68.9", "", "2", "", "", "104", "1", "2", "125", "", "0", "", "", "", "0", "", "", "", "", "1", "7.64", "0.125", "0.0031", "1.48334", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "96.4", "", "", "", "", "94.8"]} -{"pcdb_id": 17348, "brand_name": "Sime", "model_name": "Murelle Elite HE", "model_qualifier": "25", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 56.4, "output_kw_max": 23.9, "final_year_of_manufacture": 2018, "raw": ["017348", "000213", "0", "2018/Jul/11 09:53", "Fonderie Sime S.p.A.", "Sime", "Murelle Elite HE", "25", "", "2014", "2018", "2", "2", "1", "2", "0", "", "", "2", "3", "2", "23.9", "23.9", "", "", "88.8", "80.2", "", "56.4", "", "2", "1", "", "104", "1", "2", "125", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.8", "98.5", "", "", "", "", "96.9"]} -{"pcdb_id": 17349, "brand_name": "Sime", "model_name": "Murelle Elite HE", "model_qualifier": "30", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 86.8, "comparative_hot_water_efficiency_pct": 68.2, "output_kw_max": 28.9, "final_year_of_manufacture": 2018, "raw": ["017349", "000213", "0", "2018/Jul/11 09:54", "Fonderie Sime S.p.A.", "Sime", "Murelle Elite HE", "30", "", "2014", "2018", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28.9", "28.9", "", "", "87.9", "86.8", "", "68.2", "", "2", "", "", "104", "1", "2", "130", "0", "0", "", "", "", "0", "", "", "", "", "1", "7.72", "0.122", "0.0049", "1.56207", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "96.4", "", "", "", "", "94.9"]} -{"pcdb_id": 17350, "brand_name": "Sime", "model_name": "Murelle Elite HE", "model_qualifier": "30", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 56.5, "output_kw_max": 28.9, "final_year_of_manufacture": 2018, "raw": ["017350", "000213", "0", "2018/Jul/11 09:55", "Fonderie Sime S.p.A.", "Sime", "Murelle Elite HE", "30", "", "2014", "2018", "2", "2", "1", "2", "0", "", "", "2", "3", "2", "28.9", "28.9", "", "", "88.9", "80.3", "", "56.5", "", "2", "1", "", "104", "1", "2", "130", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.3", "98.5", "", "", "", "", "97.0"]} -{"pcdb_id": 17351, "brand_name": "Sime", "model_name": "Murelle Elite HE", "model_qualifier": "35", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 86.8, "comparative_hot_water_efficiency_pct": 65.4, "output_kw_max": 34.1, "final_year_of_manufacture": 2018, "raw": ["017351", "000213", "0", "2018/Jul/11 09:56", "Fonderie Sime S.p.A.", "Sime", "Murelle Elite HE", "35", "", "2014", "2018", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "34.1", "34.1", "", "", "87.9", "86.8", "", "65.4", "", "2", "", "", "104", "1", "2", "135", "", "0", "", "", "", "0", "", "", "", "", "1", "8.05", "0.131", "0.0075", "1.86473", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "96.4", "", "", "", "", "94.9"]} -{"pcdb_id": 17353, "brand_name": "Sime", "model_name": "Murelle Elite HE", "model_qualifier": "35", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 56.5, "output_kw_max": 34.1, "final_year_of_manufacture": 2018, "raw": ["017353", "000213", "0", "2018/Jul/11 09:56", "Fonderie Sime S.p.A.", "Sime", "Murelle Elite HE", "35", "", "2014", "2018", "2", "2", "1", "2", "0", "", "", "2", "3", "2", "34.1", "34.1", "", "", "88.9", "80.3", "", "56.5", "", "2", "1", "", "104", "1", "2", "140", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.3", "98.5", "", "", "", "", "97.0"]} -{"pcdb_id": 17354, "brand_name": "Sime", "model_name": "Murelle Elite HE", "model_qualifier": "35 T", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 78.9, "comparative_hot_water_efficiency_pct": 57.6, "output_kw_max": 34.1, "final_year_of_manufacture": 2018, "raw": ["017354", "000213", "0", "2018/Jul/11 09:57", "Fonderie Sime S.p.A.", "Sime", "Murelle Elite HE", "35 T", "", "2014", "2018", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "34.1", "34.1", "", "", "87.9", "78.9", "", "57.6", "", "2", "", "", "102", "1", "2", "140", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "96.4", "", "", "", "", "94.9"]} -{"pcdb_id": 17355, "brand_name": "Sime", "model_name": "Murelle Elite HE", "model_qualifier": "35 T", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 34.1, "final_year_of_manufacture": 2018, "raw": ["017355", "000213", "0", "2018/Jul/11 09:57", "Fonderie Sime S.p.A.", "Sime", "Murelle Elite HE", "35 T", "", "2014", "2018", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "34.1", "34.1", "", "", "88.9", "79.9", "", "58.4", "", "2", "1", "", "102", "1", "2", "140", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.3", "98.5", "", "", "", "", "97.0"]} -{"pcdb_id": 17356, "brand_name": "Sime", "model_name": "Murelle Pro HE", "model_qualifier": "25 R IE", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 78.9, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 23.6, "final_year_of_manufacture": 2018, "raw": ["017356", "000213", "0", "2018/Jul/11 10:30", "Fonderie Sime S.p.A.", "Sime", "Murelle Pro HE", "25 R IE", "", "2014", "2018", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "23.6", "23.6", "", "", "87.9", "78.9", "", "57.7", "", "2", "", "", "102", "1", "2", "105", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.6", "96.4", "", "", "", "", "94.9"]} -{"pcdb_id": 17357, "brand_name": "Sime", "model_name": "Murelle Pro HE", "model_qualifier": "25 R IE", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 23.6, "final_year_of_manufacture": 2018, "raw": ["017357", "000213", "0", "2018/Jul/11 10:31", "Fonderie Sime S.p.A.", "Sime", "Murelle Pro HE", "25 R IE", "", "2014", "2018", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "23.6", "23.6", "", "", "88.9", "79.9", "", "58.4", "", "2", "1", "", "102", "1", "2", "135", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.5", "98.5", "", "", "", "", "97.0"]} -{"pcdb_id": 17358, "brand_name": "Sime", "model_name": "Murelle Pro HE", "model_qualifier": "30 R IE", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 78.9, "comparative_hot_water_efficiency_pct": 57.6, "output_kw_max": 29.5, "final_year_of_manufacture": 2018, "raw": ["017358", "000213", "0", "2018/Jul/11 10:37", "Fonderie Sime S.p.A.", "Sime", "Murelle Pro HE", "30 R IE", "", "2014", "2018", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "29.5", "29.5", "", "", "87.9", "78.9", "", "57.6", "", "2", "", "", "102", "1", "2", "135", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "96.4", "", "", "", "", "94.9"]} -{"pcdb_id": 17359, "brand_name": "Sime", "model_name": "Murelle Pro HE", "model_qualifier": "30 R IE", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 29.5, "final_year_of_manufacture": 2018, "raw": ["017359", "000213", "0", "2018/Jul/11 10:39", "Fonderie Sime S.p.A.", "Sime", "Murelle Pro HE", "30 R IE", "", "2014", "2018", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "29.5", "29.5", "", "", "88.9", "79.9", "", "58.4", "", "2", "1", "", "102", "1", "2", "135", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.5", "98.5", "", "", "", "", "97.0"]} -{"pcdb_id": 17360, "brand_name": "Sime", "model_name": "Murelle Pro HE", "model_qualifier": "35 R IE", "winter_efficiency_pct": 87.8, "summer_efficiency_pct": 78.8, "comparative_hot_water_efficiency_pct": 57.6, "output_kw_max": 34.1, "final_year_of_manufacture": 2018, "raw": ["017360", "000213", "0", "2018/Jul/11 10:39", "Fonderie Sime S.p.A.", "Sime", "Murelle Pro HE", "35 R IE", "", "2014", "2018", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "34.1", "34.1", "", "", "87.8", "78.8", "", "57.6", "", "2", "", "", "102", "1", "2", "135", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "96.4", "", "", "", "", "94.8"]} -{"pcdb_id": 17361, "brand_name": "Sime", "model_name": "Murelle Pro HE", "model_qualifier": "35 R IE", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 34.1, "final_year_of_manufacture": 2018, "raw": ["017361", "000213", "0", "2018/Jul/11 11:02", "Fonderie Sime S.p.A.", "Sime", "Murelle Pro HE", "35 R IE", "", "2014", "2018", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "34.1", "34.1", "", "", "88.8", "79.8", "", "58.3", "", "2", "1", "", "102", "1", "2", "135", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.8", "98.5", "", "", "", "", "96.9"]} -{"pcdb_id": 17362, "brand_name": "Sime", "model_name": "Murelle Pro HE", "model_qualifier": "40 R IE", "winter_efficiency_pct": 87.8, "summer_efficiency_pct": 78.8, "comparative_hot_water_efficiency_pct": 57.6, "output_kw_max": 39.1, "final_year_of_manufacture": 2018, "raw": ["017362", "000213", "0", "2018/Jul/11 11:02", "Fonderie Sime S.p.A.", "Sime", "Murelle Pro HE", "40 R IE", "", "2014", "2018", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "39.1", "39.1", "", "", "87.8", "78.8", "", "57.6", "", "2", "", "", "102", "1", "2", "135", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "96.4", "", "", "", "", "94.8"]} -{"pcdb_id": 17363, "brand_name": "Sime", "model_name": "Murelle Pro HE", "model_qualifier": "40 R IE", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 39.1, "final_year_of_manufacture": 2018, "raw": ["017363", "000213", "0", "2018/Jul/11 11:03", "Fonderie Sime S.p.A.", "Sime", "Murelle Pro HE", "40 R IE", "", "2014", "2018", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "39.1", "39.1", "", "", "88.8", "79.8", "", "58.3", "", "2", "1", "", "102", "1", "2", "135", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.9", "98.5", "", "", "", "", "96.9"]} -{"pcdb_id": 17364, "brand_name": "Sime", "model_name": "Murelle Pro HE", "model_qualifier": "30 IE", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 86.9, "comparative_hot_water_efficiency_pct": 66.4, "output_kw_max": 23.6, "final_year_of_manufacture": 2018, "raw": ["017364", "000213", "0", "2018/Jul/11 10:33", "Fonderie Sime S.p.A.", "Sime", "Murelle Pro HE", "30 IE", "", "2014", "2018", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "23.6", "23.6", "", "", "87.9", "86.9", "", "66.4", "", "2", "", "", "104", "1", "2", "114", "", "0", "", "", "", "0", "", "", "", "", "1", "7.93", "0.13", "0.0052", "1.77051", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.6", "96.4", "", "", "", "", "94.9"]} -{"pcdb_id": 17365, "brand_name": "Sime", "model_name": "Murelle Pro HE", "model_qualifier": "30 IE", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 56.5, "output_kw_max": 23.6, "final_year_of_manufacture": 2018, "raw": ["017365", "000213", "0", "2018/Jul/11 10:34", "Fonderie Sime S.p.A.", "Sime", "Murelle Pro HE", "30 IE", "", "2014", "2018", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "23.6", "23.6", "", "", "88.9", "80.3", "", "56.5", "", "2", "1", "", "104", "1", "2", "114", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.5", "98.5", "", "", "", "", "97.0"]} -{"pcdb_id": 17367, "brand_name": "Daikin", "model_name": "EKOMBU28AAV1", "model_qualifier": "", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 62.1, "output_kw_max": 23.1, "final_year_of_manufacture": null, "raw": ["017367", "000278", "0", "2016/Feb/15 12:00", "Daikin Europe NV", "Daikin", "EKOMBU28AAV1", "", "GC 47-464-06", "2014", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "23.1", "23.1", "", "", "88.2", "79.6", "", "62.1", "", "2", "", "", "104", "1", "2", "105", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "", "0005", "", "", "", "", "", "", "", "", "87.9", "97.2", "", "", "", "", "95.5"]} -{"pcdb_id": 17369, "brand_name": "Daikin", "model_name": "EKOMBU33AAV1", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 62.3, "output_kw_max": 26.6, "final_year_of_manufacture": null, "raw": ["017369", "000278", "0", "2016/Feb/15 12:01", "Daikin Europe NV", "Daikin", "EKOMBU33AAV1", "", "GC 47-464-07", "2014", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "26.6", "26.6", "", "", "88.5", "79.9", "", "62.3", "", "2", "", "", "104", "1", "2", "105", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "", "0005", "", "", "", "", "", "", "", "", "88.9", "97.6", "", "", "", "", "95.9"]} -{"pcdb_id": 17371, "brand_name": "Daikin", "model_name": "EKOMBGU28AAV1", "model_qualifier": "", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 62.1, "output_kw_max": 23.1, "final_year_of_manufacture": null, "raw": ["017371", "000278", "0", "2016/Feb/15 12:02", "Daikin Europe NV", "Daikin", "EKOMBGU28AAV1", "", "GC 47-464-03", "2014", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "23.1", "23.1", "", "", "88.2", "79.6", "", "62.1", "", "2", "", "", "104", "1", "2", "80", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "", "0005", "", "", "", "", "", "", "", "", "87.9", "97.2", "", "", "", "", "95.5"]} -{"pcdb_id": 17373, "brand_name": "Daikin", "model_name": "EKOMBGU22AAV1", "model_qualifier": "", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 62.1, "output_kw_max": 18.2, "final_year_of_manufacture": null, "raw": ["017373", "000278", "0", "2016/Feb/15 12:02", "Daikin Europe NV", "Daikin", "EKOMBGU22AAV1", "", "GC 47-464-02", "2014", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "18.2", "18.2", "", "", "88.2", "79.6", "", "62.1", "", "2", "", "", "104", "1", "2", "80", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "", "0005", "", "", "", "", "", "", "", "", "87.8", "97.4", "", "", "", "", "95.6"]} -{"pcdb_id": 17375, "brand_name": "Daikin", "model_name": "EKOMBU22AAV1", "model_qualifier": "", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 62.1, "output_kw_max": 18.2, "final_year_of_manufacture": null, "raw": ["017375", "000278", "0", "2016/Feb/15 12:03", "Daikin Europe NV", "Daikin", "EKOMBU22AAV1", "", "GC 47-464-05", "2014", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "18.2", "18.2", "", "", "88.2", "79.6", "", "62.1", "", "2", "", "", "104", "1", "2", "105", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "", "0005", "", "", "", "", "", "", "", "", "87.8", "97.4", "", "", "", "", "95.6"]} -{"pcdb_id": 17377, "brand_name": "Daikin", "model_name": "EKOMBGU33AAV1", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 62.3, "output_kw_max": 26.6, "final_year_of_manufacture": null, "raw": ["017377", "000278", "0", "2016/Feb/15 12:04", "Daikin Europe NV", "Daikin", "EKOMBGU33AAV1", "", "GC 47-464-04", "2014", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "26.6", "26.6", "", "", "88.5", "79.9", "", "62.3", "", "2", "", "", "104", "1", "2", "80", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "", "0005", "", "", "", "", "", "", "", "", "88.9", "97.6", "", "", "", "", "95.9"]} -{"pcdb_id": 17378, "brand_name": "Vokera", "model_name": "Vibe", "model_qualifier": "25A", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 24.45, "final_year_of_manufacture": null, "raw": ["017378", "000011", "0", "2014/Oct/10 08:56", "Vokera", "Vokera", "Vibe", "25A", "41 094 85", "2014", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "24.45", "24.45", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "107", "4.5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "88.1", "97.7", "", "", "", "", "95.9"]} -{"pcdb_id": 17379, "brand_name": "Vokera", "model_name": "Vibe", "model_qualifier": "20A", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 19.5, "final_year_of_manufacture": null, "raw": ["017379", "000011", "0", "2014/Oct/10 08:56", "Vokera", "Vokera", "Vibe", "20A", "41 094 84", "2014", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "19.50", "19.50", "", "", "88.5", "79.5", "", "58.1", "", "2", "", "", "102", "1", "2", "96", "4.5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "87.8", "98.1", "", "", "", "", "96.2"]} -{"pcdb_id": 17380, "brand_name": "ROC", "model_name": "L1GB37-B40CP", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 56.2, "output_kw_max": 37.0, "final_year_of_manufacture": null, "raw": ["017380", "000285", "0", "2014/Nov/14 10:16", "Guangdong ROC Cool and Heat Equipment Co Ltd", "ROC", "L1GB37-B40CP", "", "", "2014", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "37", "37", "", "", "88.5", "79.9", "", "56.2", "", "2", "", "", "104", "1", "2", "110", "1", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.1", "97.9", "", "", "", "", "96.1"]} -{"pcdb_id": 17381, "brand_name": "Alpha", "model_name": "Eco2", "model_qualifier": "", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 88.5, "comparative_hot_water_efficiency_pct": 73.9, "output_kw_max": 24.0, "final_year_of_manufacture": null, "raw": ["017381", "000001", "0", "2015/Mar/16 14:39", "Alpha Therm", "Alpha", "Eco2", "", "", "2014", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "89.2", "88.5", "", "73.9", "", "2", "1", "", "104", "1", "2", "115", "4.5", "0", "", "", "", "0", "", "", "", "", "1", "7.288", "0.129", "0.009", "1.10772", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.7", "99.6", "", "", "", "", "97.7"]} -{"pcdb_id": 17382, "brand_name": "Alpha", "model_name": "Eco2", "model_qualifier": "", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 86.6, "comparative_hot_water_efficiency_pct": 72.1, "output_kw_max": 24.0, "final_year_of_manufacture": null, "raw": ["017382", "000001", "0", "2015/Apr/13 09:31", "Alpha Therm", "Alpha", "Eco2", "", "", "2014", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "88.2", "86.6", "", "72.1", "", "2", "", "", "104", "1", "2", "115", "4.5", "0", "", "", "", "0", "", "", "", "", "1", "7.308", "0.134", "0.0145", "1.09508", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "97.4", "", "", "", "", "95.6"]} -{"pcdb_id": 17383, "brand_name": "Alpha", "model_name": "InTec2 25 X", "model_qualifier": "", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 88.5, "comparative_hot_water_efficiency_pct": 74.7, "output_kw_max": 20.0, "final_year_of_manufacture": null, "raw": ["017383", "000001", "0", "2015/Mar/16 14:39", "Alpha Therm", "Alpha", "InTec2 25 X", "", "", "2014", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "20.0", "20.0", "", "", "89.2", "88.5", "", "74.7", "", "2", "1", "", "104", "1", "2", "110", "4.5", "0", "", "", "", "0", "", "", "", "", "1", "7.21", "0.132", "0.017", "0.98598", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.7", "99.5", "", "", "", "", "97.6"]} -{"pcdb_id": 17384, "brand_name": "Alpha", "model_name": "InTec2 25 X", "model_qualifier": "", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 86.6, "comparative_hot_water_efficiency_pct": 73.0, "output_kw_max": 20.0, "final_year_of_manufacture": null, "raw": ["017384", "000001", "0", "2015/Apr/13 09:31", "Alpha Therm", "Alpha", "InTec2 25 X", "", "", "2014", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "20.0", "20.0", "", "", "88.2", "86.6", "", "73.0", "", "2", "", "", "104", "1", "2", "110", "4.5", "0", "", "", "", "0", "", "", "", "", "1", "7.216", "0.133", "0.0147", "1.00537", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "97.3", "", "", "", "", "95.5"]} -{"pcdb_id": 17385, "brand_name": "Alpha", "model_name": "InTec2 28 X", "model_qualifier": "", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 88.5, "comparative_hot_water_efficiency_pct": 73.9, "output_kw_max": 24.0, "final_year_of_manufacture": null, "raw": ["017385", "000001", "0", "2015/Mar/16 14:40", "Alpha Therm", "Alpha", "InTec2 28 X", "", "", "2014", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24.0", "24.0", "", "", "89.2", "88.5", "", "73.9", "", "2", "1", "", "104", "1", "2", "115", "4.5", "0", "", "", "", "0", "", "", "", "", "1", "7.288", "0.129", "0.0091", "1.10713", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.7", "99.6", "", "", "", "", "97.7"]} -{"pcdb_id": 17386, "brand_name": "Alpha", "model_name": "InTec2 28X", "model_qualifier": "", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 86.6, "comparative_hot_water_efficiency_pct": 72.1, "output_kw_max": 24.0, "final_year_of_manufacture": null, "raw": ["017386", "000001", "0", "2015/Apr/13 09:31", "Alpha Therm", "Alpha", "InTec2 28X", "", "", "2014", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.0", "24.0", "", "", "88.2", "86.6", "", "72.1", "", "2", "", "", "104", "1", "2", "115", "4.5", "0", "", "", "", "0", "", "", "", "", "1", "7.308", "0.134", "0.0145", "1.09508", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "97.4", "", "", "", "", "95.6"]} -{"pcdb_id": 17387, "brand_name": "Worcester", "model_name": "GB 162-50 kW", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 50.0, "final_year_of_manufacture": 2016, "raw": ["017387", "000035", "0", "2020/Sep/08 10:44", "Bosch Thermotechnology", "Worcester", "GB 162-50 kW", "", "7736700642", "2015", "2016", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "50", "50", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "9", "45", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.4", "96.6", "", "", "", "", "95.0"]} -{"pcdb_id": 17388, "brand_name": "Intergas", "model_name": "Combi Compact ECO RF 36", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 87.0, "comparative_hot_water_efficiency_pct": 77.0, "output_kw_max": 26.6, "final_year_of_manufacture": null, "raw": ["017388", "000256", "0", "2018/Dec/05 13:02", "Intergas Heating Ltd", "Intergas", "Combi Compact ECO RF 36", "", "", "2013", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "26.6", "26.6", "", "", "88.5", "87.0", "", "77.0", "", "2", "", "", "104", "1", "2", "80", "2", "0", "", "", "", "0", "", "", "", "", "1", "6.838", "0.06", "0.0116", "0.68904", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.9", "97.6", "", "", "", "", "95.9"]} -{"pcdb_id": 17389, "brand_name": "Intergas", "model_name": "Combi Compact ECO RF 30", "model_qualifier": "", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 86.7, "comparative_hot_water_efficiency_pct": 76.8, "output_kw_max": 23.1, "final_year_of_manufacture": null, "raw": ["017389", "000256", "0", "2014/Nov/25 08:57", "Intergas Heating Ltd", "Intergas", "Combi Compact ECO RF 30", "", "", "2013", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "23.1", "23.1", "", "", "88.2", "86.7", "", "76.8", "", "2", "", "", "104", "1", "2", "80", "2", "0", "", "", "", "0", "", "", "", "", "1", "6.856", "0.057", "0.0", "0.74956", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "97.2", "", "", "", "", "95.5"]} -{"pcdb_id": 17390, "brand_name": "Intergas", "model_name": "Combi Compact ECO RF 24", "model_qualifier": "", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 86.6, "comparative_hot_water_efficiency_pct": 76.1, "output_kw_max": 18.2, "final_year_of_manufacture": null, "raw": ["017390", "000256", "0", "2014/Nov/25 08:57", "Intergas Heating Ltd", "Intergas", "Combi Compact ECO RF 24", "", "", "2013", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "18.2", "18.2", "", "", "88.2", "86.6", "", "76.1", "", "2", "", "", "104", "1", "2", "80", "2", "0", "", "", "", "0", "", "", "", "", "1", "6.917", "0.6", "0.0005", "0.80108", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "97.4", "", "", "", "", "95.6"]} -{"pcdb_id": 17392, "brand_name": "Viadrus", "model_name": "K4", "model_qualifier": "K4G2H24PW", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 56.1, "output_kw_max": 22.2, "final_year_of_manufacture": null, "raw": ["017392", "000292", "0", "2016/Jan/06 09:27", "Viadrus a.s", "Viadrus", "K4", "K4G2H24PW", "", "2014", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "22.2", "22.2", "", "", "88.3", "79.7", "", "56.1", "", "2", "1", "", "104", "1", "2", "65", "4", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.8", "97.3", "", "", "", "", "95.9"]} -{"pcdb_id": 17393, "brand_name": "Viadrus", "model_name": "K4", "model_qualifier": "K4G3H24PB", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 22.2, "final_year_of_manufacture": null, "raw": ["017393", "000292", "0", "2016/Jan/06 09:25", "Viadrus a.s", "Viadrus", "K4", "K4G3H24PB", "", "2014", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "22.2", "22.2", "", "", "88.3", "79.3", "", "58.0", "", "2", "1", "", "102", "1", "2", "65", "4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.8", "97.3", "", "", "", "", "95.9"]} -{"pcdb_id": 17394, "brand_name": "Viadrus", "model_name": "K4", "model_qualifier": "K4G3H24ZW", "winter_efficiency_pct": 87.4, "summer_efficiency_pct": 78.4, "comparative_hot_water_efficiency_pct": 57.2, "output_kw_max": 22.3, "final_year_of_manufacture": null, "raw": ["017394", "000292", "0", "2016/Jan/06 09:41", "Viadrus a.s", "Viadrus", "K4", "K4G3H24ZW", "", "2014", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "22.3", "22.3", "", "", "87.4", "78.4", "", "57.2", "", "2", "", "", "102", "1", "2", "65", "4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "95.2", "", "", "", "", "93.8"]} -{"pcdb_id": 17395, "brand_name": "Viadrus", "model_name": "K4", "model_qualifier": "K4G3H24ZR", "winter_efficiency_pct": 87.4, "summer_efficiency_pct": 78.4, "comparative_hot_water_efficiency_pct": 57.2, "output_kw_max": 22.3, "final_year_of_manufacture": null, "raw": ["017395", "000292", "0", "2016/Jan/06 09:40", "Viadrus a.s", "Viadrus", "K4", "K4G3H24ZR", "", "2014", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "22.3", "22.3", "", "", "87.4", "78.4", "", "57.2", "", "2", "", "", "102", "1", "2", "65", "4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "95.2", "", "", "", "", "93.8"]} -{"pcdb_id": 17396, "brand_name": "Viadrus", "model_name": "K4", "model_qualifier": "K4G3H24ZB", "winter_efficiency_pct": 87.4, "summer_efficiency_pct": 78.4, "comparative_hot_water_efficiency_pct": 57.2, "output_kw_max": 22.3, "final_year_of_manufacture": null, "raw": ["017396", "000292", "0", "2016/Jan/06 09:39", "Viadrus a.s", "Viadrus", "K4", "K4G3H24ZB", "", "2014", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "22.3", "22.3", "", "", "87.4", "78.4", "", "57.2", "", "2", "", "", "102", "1", "2", "65", "4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "95.2", "", "", "", "", "93.8"]} -{"pcdb_id": 17397, "brand_name": "Viadrus", "model_name": "K4", "model_qualifier": "K4G3H24PW", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 22.2, "final_year_of_manufacture": null, "raw": ["017397", "000292", "0", "2016/Jan/06 09:30", "Viadrus a.s", "Viadrus", "K4", "K4G3H24PW", "", "2014", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "22.2", "22.2", "", "", "88.3", "79.3", "", "58.0", "", "2", "1", "", "102", "1", "2", "65", "4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.8", "97.3", "", "", "", "", "95.9"]} -{"pcdb_id": 17398, "brand_name": "Viadrus", "model_name": "K4", "model_qualifier": "K4G3H24ZS", "winter_efficiency_pct": 87.4, "summer_efficiency_pct": 78.4, "comparative_hot_water_efficiency_pct": 57.2, "output_kw_max": 22.3, "final_year_of_manufacture": null, "raw": ["017398", "000292", "0", "2016/Jan/06 09:35", "Viadrus a.s", "Viadrus", "K4", "K4G3H24ZS", "", "2014", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "22.3", "22.3", "", "", "87.4", "78.4", "", "57.2", "", "2", "", "", "102", "1", "2", "65", "4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "95.2", "", "", "", "", "93.8"]} -{"pcdb_id": 17399, "brand_name": "Viadrus", "model_name": "K4", "model_qualifier": "K4G2H24ZB", "winter_efficiency_pct": 87.4, "summer_efficiency_pct": 78.8, "comparative_hot_water_efficiency_pct": 55.4, "output_kw_max": 22.3, "final_year_of_manufacture": null, "raw": ["017399", "000292", "0", "2016/Jan/06 09:33", "Viadrus a.s", "Viadrus", "K4", "K4G2H24ZB", "", "2014", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "22.3", "22.3", "", "", "87.4", "78.8", "", "55.4", "", "2", "", "", "104", "1", "2", "65", "4", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "95.2", "", "", "", "", "93.8"]} -{"pcdb_id": 17400, "brand_name": "Viadrus", "model_name": "K4", "model_qualifier": "K4G2H24ZR", "winter_efficiency_pct": 87.4, "summer_efficiency_pct": 78.8, "comparative_hot_water_efficiency_pct": 55.4, "output_kw_max": 22.3, "final_year_of_manufacture": null, "raw": ["017400", "000292", "0", "2016/Jan/06 09:35", "Viadrus a.s", "Viadrus", "K4", "K4G2H24ZR", "", "2014", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "22.3", "22.3", "", "", "87.4", "78.8", "", "55.4", "", "2", "", "", "104", "1", "2", "65", "4", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "95.2", "", "", "", "", "93.8"]} -{"pcdb_id": 17401, "brand_name": "Viadrus", "model_name": "K4", "model_qualifier": "K4G2H24ZW", "winter_efficiency_pct": 87.4, "summer_efficiency_pct": 78.8, "comparative_hot_water_efficiency_pct": 55.4, "output_kw_max": 22.3, "final_year_of_manufacture": null, "raw": ["017401", "000292", "0", "2016/Jan/06 09:36", "Viadrus a.s", "Viadrus", "K4", "K4G2H24ZW", "", "2014", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "22.3", "22.3", "", "", "87.4", "78.8", "", "55.4", "", "2", "", "", "104", "1", "2", "65", "4", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "95.2", "", "", "", "", "93.8"]} -{"pcdb_id": 17402, "brand_name": "Viadrus", "model_name": "K4", "model_qualifier": "K4G2H24ZS", "winter_efficiency_pct": 87.4, "summer_efficiency_pct": 78.8, "comparative_hot_water_efficiency_pct": 55.4, "output_kw_max": 22.3, "final_year_of_manufacture": null, "raw": ["017402", "000292", "0", "2016/Jan/06 09:37", "Viadrus a.s", "Viadrus", "K4", "K4G2H24ZS", "", "2014", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "22.3", "22.3", "", "", "87.4", "78.8", "", "55.4", "", "2", "", "", "104", "1", "2", "65", "4", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "95.2", "", "", "", "", "93.8"]} -{"pcdb_id": 17403, "brand_name": "Viadrus", "model_name": "K4", "model_qualifier": "K4G1H24PW", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 22.2, "final_year_of_manufacture": null, "raw": ["017403", "000292", "0", "2016/Jan/06 09:23", "Viadrus a.s", "Viadrus", "K4", "K4G1H24PW", "", "2014", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "22.2", "22.2", "", "", "88.3", "79.3", "", "58.0", "", "2", "1", "", "102", "1", "2", "65", "4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.8", "97.3", "", "", "", "", "95.9"]} -{"pcdb_id": 17404, "brand_name": "Viadrus", "model_name": "K4", "model_qualifier": "K4G1H24ZW", "winter_efficiency_pct": 87.4, "summer_efficiency_pct": 78.4, "comparative_hot_water_efficiency_pct": 57.2, "output_kw_max": 22.3, "final_year_of_manufacture": null, "raw": ["017404", "000292", "0", "2016/Jan/06 09:38", "Viadrus a.s", "Viadrus", "K4", "K4G1H24ZW", "", "2014", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "22.3", "22.3", "", "", "87.4", "78.4", "", "57.2", "", "2", "", "", "102", "1", "2", "65", "4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "95.2", "", "", "", "", "93.8"]} -{"pcdb_id": 17405, "brand_name": "Viadrus", "model_name": "K4", "model_qualifier": "K4G2H24PB", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 56.1, "output_kw_max": 22.2, "final_year_of_manufacture": null, "raw": ["017405", "000292", "0", "2016/Jan/06 09:23", "Viadrus a.s", "Viadrus", "K4", "K4G2H24PB", "", "2014", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "22.2", "22.2", "", "", "88.3", "79.7", "", "56.1", "", "2", "1", "", "104", "1", "2", "65", "4", "3", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.8", "97.3", "", "", "", "", "95.9"]} -{"pcdb_id": 17406, "brand_name": "Viadrus", "model_name": "K4", "model_qualifier": "K4G1H24PR", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 22.2, "final_year_of_manufacture": null, "raw": ["017406", "000292", "0", "2016/Jan/06 09:22", "Viadrus a.s", "Viadrus", "K4", "K4G1H24PR", "", "2014", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "22.2", "22.2", "", "", "88.3", "79.3", "", "58.0", "", "2", "1", "", "102", "1", "2", "65", "4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.8", "97.3", "", "", "", "", "95.9"]} -{"pcdb_id": 17407, "brand_name": "Viadrus", "model_name": "K4", "model_qualifier": "K4G1H24PS", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 22.2, "final_year_of_manufacture": null, "raw": ["017407", "000292", "0", "2016/Jan/06 09:22", "Viadrus a.s", "Viadrus", "K4", "K4G1H24PS", "", "2014", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "22.2", "22.2", "", "", "88.3", "79.3", "", "58.0", "", "2", "1", "", "102", "1", "2", "65", "4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.8", "97.3", "", "", "", "", "95.9"]} -{"pcdb_id": 17408, "brand_name": "Viadrus", "model_name": "K4", "model_qualifier": "K4G1H24ZS", "winter_efficiency_pct": 87.4, "summer_efficiency_pct": 78.4, "comparative_hot_water_efficiency_pct": 57.2, "output_kw_max": 22.3, "final_year_of_manufacture": null, "raw": ["017408", "000292", "0", "2016/Jan/06 09:42", "Viadrus a.s", "Viadrus", "K4", "K4G1H24ZS", "", "2014", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "22.3", "22.3", "", "", "87.4", "78.4", "", "57.2", "", "2", "", "", "102", "1", "2", "65", "4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "95.2", "", "", "", "", "93.8"]} -{"pcdb_id": 17409, "brand_name": "Viadrus", "model_name": "K4", "model_qualifier": "K4G1H24ZB", "winter_efficiency_pct": 87.4, "summer_efficiency_pct": 78.4, "comparative_hot_water_efficiency_pct": 57.2, "output_kw_max": 22.3, "final_year_of_manufacture": null, "raw": ["017409", "000292", "0", "2016/Jan/06 09:34", "Viadrus a.s", "Viadrus", "K4", "K4G1H24ZB", "", "2014", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "22.3", "22.3", "", "", "87.4", "78.4", "", "57.2", "", "2", "", "", "102", "1", "2", "65", "4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "95.2", "", "", "", "", "93.8"]} -{"pcdb_id": 17410, "brand_name": "Viadrus", "model_name": "K4", "model_qualifier": "K4G1H24PB", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 22.2, "final_year_of_manufacture": null, "raw": ["017410", "000292", "0", "2016/Jan/06 09:29", "Viadrus a.s", "Viadrus", "K4", "K4G1H24PB", "", "2014", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "22.2", "22.2", "", "", "88.3", "79.3", "", "58.0", "", "2", "1", "", "102", "1", "2", "65", "4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.8", "97.3", "", "", "", "", "95.9"]} -{"pcdb_id": 17411, "brand_name": "Viadrus", "model_name": "K4", "model_qualifier": "K4G2H24PR", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 56.1, "output_kw_max": 22.4, "final_year_of_manufacture": null, "raw": ["017411", "000292", "0", "2016/Jan/06 09:28", "Viadrus a.s", "Viadrus", "K4", "K4G2H24PR", "", "2014", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "22.4", "22.4", "", "", "88.3", "79.7", "", "56.1", "", "2", "1", "", "104", "1", "2", "65", "4", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.8", "97.3", "", "", "", "", "95.9"]} -{"pcdb_id": 17412, "brand_name": "Viadrus", "model_name": "K4", "model_qualifier": "K4G1H24ZR", "winter_efficiency_pct": 87.4, "summer_efficiency_pct": 78.4, "comparative_hot_water_efficiency_pct": 57.2, "output_kw_max": 22.3, "final_year_of_manufacture": null, "raw": ["017412", "000292", "0", "2016/Jan/06 09:31", "Viadrus a.s", "Viadrus", "K4", "K4G1H24ZR", "", "2014", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "22.3", "22.3", "", "", "87.4", "78.4", "", "57.2", "", "2", "", "", "102", "1", "2", "65", "4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "95.2", "", "", "", "", "93.8"]} -{"pcdb_id": 17413, "brand_name": "Viadrus", "model_name": "K4", "model_qualifier": "K4G2H24PS", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 56.1, "output_kw_max": 22.2, "final_year_of_manufacture": null, "raw": ["017413", "000292", "0", "2016/Jan/06 09:21", "Viadrus a.s", "Viadrus", "K4", "K4G2H24PS", "", "2014", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "22.2", "22.2", "", "", "88.3", "79.7", "", "56.1", "", "2", "1", "", "104", "1", "2", "65", "4", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.8", "97.3", "", "", "", "", "95.9"]} -{"pcdb_id": 17414, "brand_name": "Viadrus", "model_name": "K4", "model_qualifier": "K4G3H24PR", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 22.2, "final_year_of_manufacture": null, "raw": ["017414", "000292", "0", "2016/Jan/06 09:26", "Viadrus a.s", "Viadrus", "K4", "K4G3H24PR", "", "2014", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "22.2", "22.2", "", "", "88.3", "79.3", "", "58.0", "", "2", "1", "", "102", "1", "2", "65", "4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.8", "97.3", "", "", "", "", "95.9"]} -{"pcdb_id": 17415, "brand_name": "Viadrus", "model_name": "K4", "model_qualifier": "K4G3H24PS", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 22.2, "final_year_of_manufacture": null, "raw": ["017415", "000292", "0", "2016/Jan/06 09:31", "Viadrus a.s", "Viadrus", "K4", "K4G3H24PS", "", "2014", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "22.2", "22.2", "", "", "88.3", "79.3", "", "58.0", "", "2", "1", "", "102", "1", "2", "65", "4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.8", "97.3", "", "", "", "", "95.9"]} -{"pcdb_id": 17417, "brand_name": "Viessmann", "model_name": "Vitodens 050-W BPJC", "model_qualifier": "29kW Combi Boiler", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 84.7, "comparative_hot_water_efficiency_pct": 64.0, "output_kw_max": 21.8, "final_year_of_manufacture": 2016, "raw": ["017417", "000033", "0", "2020/Apr/09 16:18", "Viessmann", "Viessmann", "Vitodens 050-W BPJC", "29kW Combi Boiler", "GC 47 819 31", "2014", "2016", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "21.8", "21.8", "", "", "88.4", "84.7", "", "64.0", "", "2", "", "", "104", "1", "2", "97", "2.71", "0", "", "", "0", "0", "", "", "", "", "2", "8.235", "0.114", "0.0111", "2.00571", "14.399", "0.134", "0.004", "1.67227", "0.00007", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "98.0", "", "", "", "", "96.1"]} -{"pcdb_id": 17419, "brand_name": "Viessmann", "model_name": "Vitodens 050-W BPJC", "model_qualifier": "35kW Combi Boiler", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 84.1, "comparative_hot_water_efficiency_pct": 64.2, "output_kw_max": 30.1, "final_year_of_manufacture": 2016, "raw": ["017419", "000033", "0", "2020/Apr/09 16:18", "Viessmann", "Viessmann", "Vitodens 050-W BPJC", "35kW Combi Boiler", "GC 47 819 32", "2014", "2016", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "30.1", "30.1", "", "", "88.4", "84.1", "", "64.2", "", "2", "", "", "104", "1", "2", "141", "2.71", "0", "", "", "", "0", "", "", "", "", "2", "8.201", "0.121", "0.0054", "2.00903", "14.415", "0.141", "0.002", "1.62647", "0.00003", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "97.9", "", "", "", "", "96.0"]} -{"pcdb_id": 17422, "brand_name": "Unical", "model_name": "KON C HE", "model_qualifier": "Combi Boiler", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 56.1, "output_kw_max": 17.4, "final_year_of_manufacture": null, "raw": ["017422", "000263", "0", "2015/Feb/24 10:54", "Unical AG", "Unical", "KON C HE", "Combi Boiler", "", "2013", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "17.4", "17.4", "", "", "88.4", "79.8", "", "56.1", "", "2", "", "", "104", "1", "2", "108", "9", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.1", "97.8", "", "", "", "", "95.9"]} -{"pcdb_id": 17423, "brand_name": "Unical", "model_name": "KON R HE", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 17.4, "final_year_of_manufacture": null, "raw": ["017423", "000263", "0", "2015/Feb/24 10:54", "Unical AG", "Unical", "KON R HE", "", "", "2013", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "17.4", "17.4", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "108", "9", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.1", "97.8", "", "", "", "", "95.9"]} -{"pcdb_id": 17424, "brand_name": "Unical", "model_name": "KON C 28 HE", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 56.2, "output_kw_max": 27.2, "final_year_of_manufacture": null, "raw": ["017424", "000263", "0", "2015/Feb/24 10:55", "Unical AG", "Unical", "KON C 28 HE", "", "", "2014", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "27.2", "27.2", "", "", "88.5", "79.9", "", "56.2", "", "2", "", "", "104", "1", "2", "116", "9", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "97.9", "", "", "", "", "96.1"]} -{"pcdb_id": 17425, "brand_name": "Unical", "model_name": "KON R 28 HE", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 27.2, "final_year_of_manufacture": null, "raw": ["017425", "000263", "0", "2015/Feb/24 10:55", "Unical AG", "Unical", "KON R 28 HE", "", "", "2014", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "27.2", "27.2", "", "", "88.5", "79.5", "", "58.0", "", "2", "", "", "102", "1", "2", "116", "9", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "97.9", "", "", "", "", "96.1"]} -{"pcdb_id": 17430, "brand_name": "Ravenheat", "model_name": "CS 80(T)", "model_qualifier": "Natural Gas", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 86.6, "comparative_hot_water_efficiency_pct": 76.3, "output_kw_max": 19.5, "final_year_of_manufacture": null, "raw": ["017430", "000026", "0", "2015/May/06 11:50", "Ravenheat Manufacturing", "Ravenheat", "CS 80(T)", "Natural Gas", "", "2015", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "19.5", "19.5", "", "", "88.0", "86.6", "", "76.3", "", "2", "", "", "104", "1", "2", "110", "3", "0", "", "", "", "0", "", "", "", "", "1", "6.902", "0.134", "0.0104", "0.73076", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "96.9", "", "", "", "", "95.2"]} -{"pcdb_id": 17434, "brand_name": "Ravenheat", "model_name": "CS 90 (T)", "model_qualifier": "Natural Gas", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 86.7, "comparative_hot_water_efficiency_pct": 68.6, "output_kw_max": 23.9, "final_year_of_manufacture": null, "raw": ["017434", "000026", "0", "2015/May/06 11:50", "Ravenheat Manufacturing", "Ravenheat", "CS 90 (T)", "Natural Gas", "", "2015", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "23.9", "23.9", "", "", "88.1", "86.7", "", "68.6", "", "2", "", "", "104", "1", "2", "160", "3", "0", "", "", "", "0", "", "", "", "", "1", "7.674", "0.129", "0.0065", "1.49867", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "96.9", "", "", "", "", "95.2"]} -{"pcdb_id": 17435, "brand_name": "Firebird", "model_name": "Enviromax Kitchen", "model_qualifier": "C12/18kW", "winter_efficiency_pct": 89.5, "summer_efficiency_pct": 81.7, "comparative_hot_water_efficiency_pct": 59.7, "output_kw_max": 18.0, "final_year_of_manufacture": null, "raw": ["017435", "000047", "0", "2015/Mar/05 11:16", "Firebird Heating Solutions Ltd", "Firebird", "Enviromax Kitchen", "C12/18kW", "", "2011", "current", "4", "1", "1", "1", "0", "", "", "2", "2", "1", "12", "18", "", "", "89.5", "81.7", "", "59.7", "", "2", "", "", "201", "1", "1", "38", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "92.7", "97.8", "", "", "", "", "96.8"]} -{"pcdb_id": 17436, "brand_name": "Firebird", "model_name": "Blue Flame Enviromax Popular", "model_qualifier": "26kW", "winter_efficiency_pct": 89.7, "summer_efficiency_pct": 81.9, "comparative_hot_water_efficiency_pct": 59.8, "output_kw_max": 26.0, "final_year_of_manufacture": null, "raw": ["017436", "000047", "0", "2015/Mar/05 11:16", "Firebird Heating Solutions Ltd", "Firebird", "Blue Flame Enviromax Popular", "26kW", "", "2014", "current", "4", "1", "1", "1", "0", "", "", "2", "2", "1", "26", "26", "", "", "89.7", "81.9", "", "59.8", "", "2", "", "", "201", "1", "1", "38", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "94.2", "97.6", "", "", "", "", "97.0"]} -{"pcdb_id": 17437, "brand_name": "Sime", "model_name": "Murelle Elite HE 35 ErP", "model_qualifier": "", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 86.8, "comparative_hot_water_efficiency_pct": 69.1, "output_kw_max": 34.1, "final_year_of_manufacture": null, "raw": ["017437", "000213", "0", "2015/Jun/12 09:59", "Fonderie Sime S.p.A.", "Sime", "Murelle Elite HE 35 ErP", "", "47-283-71", "2015", "current", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "34.1", "34.1", "", "", "87.9", "86.8", "", "69.1", "", "2", "", "", "104", "1", "2", "93", "", "0", "", "", "", "0", "", "", "", "", "1", "7.62", "0.107", "0.0054", "1.46283", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "96.4", "", "", "", "", "94.9"]} -{"pcdb_id": 17438, "brand_name": "Sime", "model_name": "Murelle Elite HE 35 ErP", "model_qualifier": "", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 88.7, "comparative_hot_water_efficiency_pct": 70.8, "output_kw_max": 34.1, "final_year_of_manufacture": 2018, "raw": ["017438", "000213", "0", "2018/Jul/11 10:01", "Fonderie Sime S.p.A.", "Sime", "Murelle Elite HE 35 ErP", "", "47-283-71", "2015", "2018", "2", "2", "1", "2", "0", "", "", "2", "3", "2", "34.1", "34.1", "", "", "88.9", "88.7", "", "70.8", "", "2", "1", "", "104", "1", "2", "93", "4.3", "0", "", "", "", "0", "", "", "", "", "1", "7.6", "0.11", "0.0046", "1.44824", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.3", "98.5", "", "", "", "", "97.0"]} -{"pcdb_id": 17439, "brand_name": "Sime", "model_name": "Murelle Elite HE 35 T ErP", "model_qualifier": "", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 78.9, "comparative_hot_water_efficiency_pct": 57.6, "output_kw_max": 34.1, "final_year_of_manufacture": null, "raw": ["017439", "000213", "0", "2015/May/05 09:20", "Fonderie Sime S.p.A.", "Sime", "Murelle Elite HE 35 T ErP", "", "41-283-54", "2015", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "34.1", "34.1", "", "", "87.9", "78.9", "", "57.6", "", "2", "", "", "102", "1", "2", "93", "4.3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "96.4", "", "", "", "", "94.9"]} -{"pcdb_id": 17442, "brand_name": "Sime", "model_name": "Murelle Elite HE 35 T ErP", "model_qualifier": "", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 34.1, "final_year_of_manufacture": 2018, "raw": ["017442", "000213", "0", "2018/Jul/11 10:02", "Fonderie Sime S.p.A.", "Sime", "Murelle Elite HE 35 T ErP", "", "41-283-54", "2015", "2018", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "34.1", "34.1", "", "", "88.9", "79.9", "", "58.4", "", "2", "1", "", "102", "1", "2", "93", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.3", "98.5", "", "", "", "", "97.0"]} -{"pcdb_id": 17444, "brand_name": "Sime", "model_name": "Murelle Elite HE 30 ErP", "model_qualifier": "", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 86.8, "comparative_hot_water_efficiency_pct": 70.3, "output_kw_max": 28.9, "final_year_of_manufacture": null, "raw": ["017444", "000213", "0", "2015/Jun/12 10:05", "Fonderie Sime S.p.A.", "Sime", "Murelle Elite HE 30 ErP", "", "", "2015", "current", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "28.9", "28.9", "", "", "87.9", "86.8", "", "70.3", "", "2", "", "", "104", "1", "2", "83", "4.3", "0", "", "", "", "0", "", "", "", "", "1", "7.49", "0.11", "0.0061", "1.33382", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "96.4", "", "", "", "", "94.9"]} -{"pcdb_id": 17446, "brand_name": "Sime", "model_name": "Murelle Elite HE 30 ErP", "model_qualifier": "", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 88.7, "comparative_hot_water_efficiency_pct": 71.5, "output_kw_max": 28.9, "final_year_of_manufacture": 2018, "raw": ["017446", "000213", "0", "2018/Jul/11 09:59", "Fonderie Sime S.p.A.", "Sime", "Murelle Elite HE 30 ErP", "", "47-283-70", "2015", "2018", "2", "2", "1", "2", "0", "", "", "2", "3", "2", "28.9", "28.9", "", "", "88.9", "88.7", "", "71.5", "", "2", "1", "", "104", "1", "2", "83", "", "0", "", "", "", "0", "", "", "", "", "1", "7.53", "0.104", "0.0059", "1.37322", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.3", "98.5", "", "", "", "", "97.0"]} -{"pcdb_id": 17448, "brand_name": "Sime", "model_name": "Murelle Elite HE 25 ErP", "model_qualifier": "", "winter_efficiency_pct": 87.8, "summer_efficiency_pct": 86.6, "comparative_hot_water_efficiency_pct": 71.6, "output_kw_max": 23.9, "final_year_of_manufacture": 2018, "raw": ["017448", "000213", "0", "2018/Jul/11 09:58", "Fonderie Sime S.p.A.", "Sime", "Murelle Elite HE 25 ErP", "", "", "2015", "2018", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "23.9", "23.9", "", "", "87.8", "86.6", "", "71.6", "", "2", "", "", "104", "1", "2", "84", "4.3", "0", "", "", "", "0", "", "", "", "", "1", "7.36", "0.101", "0.0053", "1.20125", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "96.4", "", "", "", "", "94.8"]} -{"pcdb_id": 17449, "brand_name": "Sime", "model_name": "Murelle Elite HE 25 ErP", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 88.6, "comparative_hot_water_efficiency_pct": 73.2, "output_kw_max": 23.9, "final_year_of_manufacture": 2018, "raw": ["017449", "000213", "0", "2018/Jul/11 09:59", "Fonderie Sime S.p.A.", "Sime", "Murelle Elite HE 25 ErP", "", "", "2015", "2018", "2", "2", "1", "2", "0", "", "", "2", "3", "2", "23.9", "23.9", "", "", "88.8", "88.6", "", "73.2", "", "2", "1", "", "104", "1", "2", "84", "4.3", "0", "", "", "", "0", "", "", "", "", "1", "7.35", "0.106", "0.0057", "1.189", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.8", "98.5", "", "", "", "", "96.9"]} -{"pcdb_id": 17450, "brand_name": "Sime", "model_name": "Murelle PRO HE 40 R IE ErP", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 39.1, "final_year_of_manufacture": 2018, "raw": ["017450", "000213", "0", "2018/Jul/11 11:25", "Fonderie Sime S.p.A.", "Sime", "Murelle PRO HE 40 R IE ErP", "", "", "2015", "2018", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "39.1", "39.1", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "111", "3.6", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.7", "96.4", "", "", "", "", "95.0"]} -{"pcdb_id": 17451, "brand_name": "Sime", "model_name": "Murelle PRO HE 40 R IE ErP", "model_qualifier": "", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 39.1, "final_year_of_manufacture": 2018, "raw": ["017451", "000213", "0", "2018/Jul/11 11:26", "Fonderie Sime S.p.A.", "Sime", "Murelle PRO HE 40 R IE ErP", "", "", "2015", "2018", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "39.1", "39.1", "", "", "89.0", "80.0", "", "58.4", "", "2", "1", "", "102", "1", "2", "111", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.7", "98.5", "", "", "", "", "97.1"]} -{"pcdb_id": 17452, "brand_name": "Sime", "model_name": "Murelle PRO HE 35 R IE ErP", "model_qualifier": "", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 78.9, "comparative_hot_water_efficiency_pct": 57.6, "output_kw_max": 34.1, "final_year_of_manufacture": 2018, "raw": ["017452", "000213", "0", "2018/Jul/11 11:25", "Fonderie Sime S.p.A.", "Sime", "Murelle PRO HE 35 R IE ErP", "", "", "2015", "2018", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "34.1", "34.1", "", "", "87.9", "78.9", "", "57.6", "", "2", "", "", "102", "1", "2", "92", "3.6", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.4", "96.4", "", "", "", "", "94.9"]} -{"pcdb_id": 17453, "brand_name": "Sime", "model_name": "Murelle PRO HE 35 R IE ErP", "model_qualifier": "", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 34.1, "final_year_of_manufacture": 2018, "raw": ["017453", "000213", "0", "2018/Jul/11 11:25", "Fonderie Sime S.p.A.", "Sime", "Murelle PRO HE 35 R IE ErP", "", "", "2015", "2018", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "34.1", "34.1", "", "", "88.9", "79.9", "", "58.4", "", "2", "1", "", "102", "1", "2", "92", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.4", "98.5", "", "", "", "", "97.0"]} -{"pcdb_id": 17454, "brand_name": "Sime", "model_name": "Murelle PRO HE 30 R IE ErP", "model_qualifier": "", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 78.9, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 29.5, "final_year_of_manufacture": 2018, "raw": ["017454", "000213", "0", "2018/Jul/11 11:24", "Fonderie Sime S.p.A.", "Sime", "Murelle PRO HE 30 R IE ErP", "", "", "2015", "2018", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "29.5", "29.5", "", "", "87.9", "78.9", "", "57.7", "", "2", "", "", "102", "1", "2", "78", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.6", "96.4", "", "", "", "", "94.9"]} -{"pcdb_id": 17455, "brand_name": "Sime", "model_name": "Murelle PRO HE 30 R IE ErP", "model_qualifier": "", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 29.5, "final_year_of_manufacture": 2018, "raw": ["017455", "000213", "0", "2018/Jul/11 11:24", "Fonderie Sime S.p.A.", "Sime", "Murelle PRO HE 30 R IE ErP", "", "", "2015", "2018", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "29.5", "29.5", "", "", "88.9", "79.9", "", "58.4", "", "2", "1", "", "102", "1", "2", "78", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.5", "98.5", "", "", "", "", "97.0"]} -{"pcdb_id": 17456, "brand_name": "Sime", "model_name": "Murelle PRO HE 30 IE ErP", "model_qualifier": "", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 86.9, "comparative_hot_water_efficiency_pct": 73.2, "output_kw_max": 23.6, "final_year_of_manufacture": 2018, "raw": ["017456", "000213", "0", "2018/Jul/11 11:21", "Fonderie Sime S.p.A.", "Sime", "Murelle PRO HE 30 IE ErP", "", "", "2015", "2018", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "23.6", "23.6", "", "", "87.9", "86.9", "", "73.2", "", "2", "", "", "104", "1", "2", "85", "3.6", "0", "", "", "", "0", "", "", "", "", "1", "7.19", "0.115", "0.0051", "1.05776", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.6", "96.4", "", "", "", "", "94.9"]} -{"pcdb_id": 17457, "brand_name": "Sime", "model_name": "Murelle PRO HE 30 IE ErP", "model_qualifier": "", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 88.8, "comparative_hot_water_efficiency_pct": 74.5, "output_kw_max": 23.6, "final_year_of_manufacture": 2018, "raw": ["017457", "000213", "0", "2018/Jul/11 11:21", "Fonderie Sime S.p.A.", "Sime", "Murelle PRO HE 30 IE ErP", "", "", "2015", "2018", "2", "2", "1", "2", "0", "", "", "2", "3", "2", "23.6", "23.6", "", "", "88.9", "88.8", "", "74.5", "", "2", "1", "", "104", "1", "2", "85", "", "0", "", "", "", "0", "", "", "", "", "1", "7.23", "0.111", "0.004", "1.10276", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.5", "98.5", "", "", "", "", "97.0"]} -{"pcdb_id": 17458, "brand_name": "Sime", "model_name": "Murelle PRO HE 25 R IE ErP", "model_qualifier": "", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 78.9, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 23.6, "final_year_of_manufacture": 2018, "raw": ["017458", "000213", "0", "2018/Jul/11 11:16", "Fonderie Sime S.p.A.", "Sime", "Murelle PRO HE 25 R IE ErP", "", "", "2015", "2018", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "23.6", "23.6", "", "", "87.9", "78.9", "", "57.7", "", "2", "", "", "102", "1", "2", "73", "3.6", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.6", "96.4", "", "", "", "", "94.9"]} -{"pcdb_id": 17459, "brand_name": "Sime", "model_name": "Murelle PRO HE 25 R IE ErP", "model_qualifier": "", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 23.6, "final_year_of_manufacture": 2018, "raw": ["017459", "000213", "0", "2018/Jul/11 11:18", "Fonderie Sime S.p.A.", "Sime", "Murelle PRO HE 25 R IE ErP", "", "", "2015", "2018", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "23.6", "23.6", "", "", "88.9", "79.9", "", "58.4", "", "2", "1", "", "102", "1", "2", "73", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.5", "98.5", "", "", "", "", "97.0"]} -{"pcdb_id": 17460, "brand_name": "Sime", "model_name": "Murelle PRO HE 30 R ErP", "model_qualifier": "", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 78.9, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 29.5, "final_year_of_manufacture": 2018, "raw": ["017460", "000213", "0", "2018/Jul/11 11:22", "Fonderie Sime S.p.A.", "Sime", "Murelle PRO HE 30 R ErP", "", "", "2015", "2018", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "29.5", "29.5", "", "", "87.9", "78.9", "", "57.7", "", "2", "", "", "102", "1", "2", "78", "3.6", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.6", "96.4", "", "", "", "", "94.9"]} -{"pcdb_id": 17461, "brand_name": "Sime", "model_name": "Murelle PRO HE 30 R ErP", "model_qualifier": "", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 29.5, "final_year_of_manufacture": 2018, "raw": ["017461", "000213", "0", "2018/Jul/11 11:23", "Fonderie Sime S.p.A.", "Sime", "Murelle PRO HE 30 R ErP", "", "", "2015", "2018", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "29.5", "29.5", "", "", "88.9", "79.9", "", "58.4", "", "2", "1", "", "102", "1", "2", "78", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.5", "98.5", "", "", "", "", "97.0"]} -{"pcdb_id": 17462, "brand_name": "Sime", "model_name": "Murelle PRO HE 30 ErP", "model_qualifier": "", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 86.9, "comparative_hot_water_efficiency_pct": 73.2, "output_kw_max": 23.6, "final_year_of_manufacture": 2018, "raw": ["017462", "000213", "0", "2018/Jul/11 11:20", "Fonderie Sime S.p.A.", "Sime", "Murelle PRO HE 30 ErP", "", "47-283-66", "2015", "2018", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "23.6", "23.6", "", "", "87.9", "86.9", "", "73.2", "", "2", "", "", "104", "1", "2", "85", "3.6", "0", "", "", "", "0", "", "", "", "", "1", "7.19", "0.115", "0.0051", "1.05776", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.6", "96.4", "", "", "", "", "94.9"]} -{"pcdb_id": 17463, "brand_name": "Sime", "model_name": "Murelle PRO HE 30 ErP", "model_qualifier": "", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 88.8, "comparative_hot_water_efficiency_pct": 74.5, "output_kw_max": 23.6, "final_year_of_manufacture": 2018, "raw": ["017463", "000213", "0", "2018/Jul/11 11:20", "Fonderie Sime S.p.A.", "Sime", "Murelle PRO HE 30 ErP", "", "47-283-66", "2015", "2018", "2", "2", "1", "2", "0", "", "", "2", "3", "2", "23.6", "23.6", "", "", "88.9", "88.8", "", "74.5", "", "2", "1", "", "104", "1", "2", "85", "", "0", "", "", "0", "0", "", "", "", "", "1", "7.23", "0.111", "0.004", "1.10276", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.5", "98.5", "", "", "", "", "97.0"]} -{"pcdb_id": 17464, "brand_name": "Sime", "model_name": "Murelle PRO HE 25 LPG ErP", "model_qualifier": "", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 88.8, "comparative_hot_water_efficiency_pct": 70.6, "output_kw_max": 19.7, "final_year_of_manufacture": 2018, "raw": ["017464", "000213", "0", "2018/Jul/11 11:15", "Fonderie Sime S.p.A.", "Sime", "Murelle PRO HE 25 LPG ErP", "", "", "2015", "2018", "2", "2", "1", "2", "0", "", "", "2", "3", "2", "19.7", "19.7", "", "", "88.9", "88.8", "", "70.6", "", "2", "1", "", "104", "1", "2", "70", "3.6", "0", "", "", "", "0", "", "", "", "", "1", "7.62", "0.108", "0.008", "1.4554", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.5", "98.5", "", "", "", "", "97.0"]} -{"pcdb_id": 17465, "brand_name": "Sime", "model_name": "Murelle PRO HE 25 HO ErP", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 23.6, "final_year_of_manufacture": 2018, "raw": ["017465", "000213", "0", "2018/Jul/11 11:09", "Fonderie Sime S.p.A.", "Sime", "Murelle PRO HE 25 HO ErP", "", "41-283-53", "2015", "2018", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "23.6", "23.6", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "34", "3.6", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.7", "96.4", "", "", "", "", "95.0"]} -{"pcdb_id": 17466, "brand_name": "Sime", "model_name": "Murelle PRO HE 25 HO ErP", "model_qualifier": "", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 23.6, "final_year_of_manufacture": 2018, "raw": ["017466", "000213", "0", "2018/Jul/11 11:15", "Fonderie Sime S.p.A.", "Sime", "Murelle PRO HE 25 HO ErP", "", "41-283-53", "2015", "2018", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "23.6", "23.6", "", "", "89.0", "80.0", "", "58.4", "", "2", "1", "", "102", "1", "2", "34", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.7", "98.5", "", "", "", "", "97.1"]} -{"pcdb_id": 17467, "brand_name": "Sime", "model_name": "Murelle PRO HE 25 ErP", "model_qualifier": "", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 86.9, "comparative_hot_water_efficiency_pct": 68.8, "output_kw_max": 19.7, "final_year_of_manufacture": 2018, "raw": ["017467", "000213", "0", "2018/Jul/11 11:05", "Fonderie Sime S.p.A.", "Sime", "Murelle PRO HE 25 ErP", "", "", "2015", "2018", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "19.7", "19.7", "", "", "87.9", "86.9", "", "68.8", "", "2", "", "", "104", "1", "2", "70", "3.6", "0", "", "", "", "0", "", "", "", "", "1", "7.65", "0.105", "0.007", "1.48988", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.6", "96.4", "", "", "", "", "94.9"]} -{"pcdb_id": 17468, "brand_name": "Sime", "model_name": "Murelle PRO HE 25 ErP", "model_qualifier": "", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 88.8, "comparative_hot_water_efficiency_pct": 70.6, "output_kw_max": 19.7, "final_year_of_manufacture": 2018, "raw": ["017468", "000213", "0", "2018/Jul/11 11:06", "Fonderie Sime S.p.A.", "Sime", "Murelle PRO HE 25 ErP", "", "47-283-65", "2015", "2018", "2", "2", "1", "2", "0", "", "", "2", "3", "2", "19.7", "19.7", "", "", "88.9", "88.8", "", "70.6", "", "2", "1", "", "104", "1", "2", "70", "", "0", "", "", "", "0", "", "", "", "", "1", "7.62", "0.108", "0.008", "1.4554", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.5", "98.5", "", "", "", "", "97.0"]} -{"pcdb_id": 17469, "brand_name": "Sime", "model_name": "Murelle PRO HE 20 R ErP", "model_qualifier": "", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 78.9, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 19.7, "final_year_of_manufacture": 2018, "raw": ["017469", "000213", "0", "2018/Jul/11 11:03", "Fonderie Sime S.p.A.", "Sime", "Murelle PRO HE 20 R ErP", "", "41-283-51", "2015", "2018", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "19.7", "19.7", "", "", "87.9", "78.9", "", "57.7", "", "2", "", "", "102", "1", "2", "65", "3.6", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.6", "96.4", "", "", "", "", "94.9"]} -{"pcdb_id": 17470, "brand_name": "Sime", "model_name": "Murelle PRO HE 20 R ErP", "model_qualifier": "", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 19.7, "final_year_of_manufacture": 2018, "raw": ["017470", "000213", "0", "2018/Jul/11 11:04", "Fonderie Sime S.p.A.", "Sime", "Murelle PRO HE 20 R ErP", "", "41-283-51", "2015", "2018", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "19.7", "19.7", "", "", "88.9", "79.9", "", "58.4", "", "2", "1", "", "102", "1", "2", "65", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.5", "98.5", "", "", "", "", "97.0"]} -{"pcdb_id": 17471, "brand_name": "Sime", "model_name": "Murelle Advanced HE 40 ErP", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 87.0, "comparative_hot_water_efficiency_pct": 65.8, "output_kw_max": 34.5, "final_year_of_manufacture": 2018, "raw": ["017471", "000213", "0", "2018/Jul/11 09:51", "Fonderie Sime S.p.A.", "Sime", "Murelle Advanced HE 40 ErP", "", "47-283-69", "2015", "2018", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "34.5", "34.5", "", "", "88.0", "87.0", "", "65.8", "", "2", "", "", "104", "1", "2", "111", "", "0", "", "", "", "0", "", "", "", "", "1", "7.998", "0.108", "0.0056", "1.84143", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.8", "96.4", "", "", "", "", "95.0"]} -{"pcdb_id": 17472, "brand_name": "Sime", "model_name": "Murelle Advanced HE 40 ErP", "model_qualifier": "", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 88.9, "comparative_hot_water_efficiency_pct": 67.0, "output_kw_max": 34.5, "final_year_of_manufacture": 2018, "raw": ["017472", "000213", "0", "2018/Jul/11 09:52", "Fonderie Sime S.p.A.", "Sime", "Murelle Advanced HE 40 ErP", "", "47-283-69", "2015", "2018", "2", "2", "1", "2", "0", "", "", "2", "3", "2", "34.5", "34.5", "", "", "89.0", "88.9", "", "67.0", "", "2", "1", "", "104", "1", "2", "111", "3.6", "0", "", "", "", "0", "", "", "", "", "1", "8.03", "0.111", "0.0055", "1.87319", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.8", "98.5", "", "", "", "", "97.1"]} -{"pcdb_id": 17473, "brand_name": "Sime", "model_name": "Murelle Advanced HE 30 ErP", "model_qualifier": "", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 86.9, "comparative_hot_water_efficiency_pct": 69.0, "output_kw_max": 23.6, "final_year_of_manufacture": 2018, "raw": ["017473", "000213", "0", "2018/Jul/11 09:50", "Fonderie Sime S.p.A.", "Sime", "Murelle Advanced HE 30 ErP", "", "47-283-68", "2015", "2018", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "23.6", "23.6", "", "", "87.9", "86.9", "", "69.0", "", "2", "", "", "104", "1", "2", "85", "3.6", "0", "", "", "", "0", "", "", "", "", "1", "7.63", "0.118", "0.0058", "1.4779", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.6", "96.4", "", "", "", "", "94.9"]} -{"pcdb_id": 17474, "brand_name": "Sime", "model_name": "Murelle Advanced HE 30 ErP", "model_qualifier": "", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 88.8, "comparative_hot_water_efficiency_pct": 70.6, "output_kw_max": 23.6, "final_year_of_manufacture": 2018, "raw": ["017474", "000213", "0", "2018/Jul/11 09:50", "Fonderie Sime S.p.A.", "Sime", "Murelle Advanced HE 30 ErP", "", "47-283-68", "2015", "2018", "2", "2", "1", "2", "0", "", "", "2", "3", "2", "23.6", "23.6", "", "", "88.9", "88.8", "", "70.6", "", "2", "1", "", "104", "1", "2", "85", "", "0", "", "", "", "0", "", "", "", "", "1", "7.63", "0.122", "0.0059", "1.47732", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.5", "98.5", "", "", "", "", "97.0"]} -{"pcdb_id": 17475, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "9i System ErP LPG", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 9.0, "final_year_of_manufacture": null, "raw": ["017475", "000035", "0", "2017/May/15 15:31", "Bosch Thermotechnology", "Worcester", "Greenstar", "9i System ErP LPG", "41-406-22", "2015", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "9.0", "9.0", "", "", "89.1", "80.1", "", "58.5", "", "2", "0", "0", "102", "1", "2", "95", "1.7", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "8325", "", "", "", "", "", "", "", "", "89.2", "97.0", "", "", "", "", "95.5"]} -{"pcdb_id": 17476, "brand_name": "Ideal", "model_name": "INSTINCT", "model_qualifier": "24", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 62.2, "output_kw_max": 24.2, "final_year_of_manufacture": null, "raw": ["017476", "000008", "0", "2015/Apr/20 13:08", "Ideal Boilers", "Ideal", "INSTINCT", "24", "47-349-09", "2015", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "88.3", "79.7", "", "62.2", "", "2", "", "", "104", "1", "2", "146", "1", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "", "0035", "", "", "", "", "", "", "", "", "89.8", "96.9", "", "", "", "", "95.5"]} -{"pcdb_id": 17477, "brand_name": "Ideal", "model_name": "INSTINCT", "model_qualifier": "30", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 62.3, "output_kw_max": 24.2, "final_year_of_manufacture": null, "raw": ["017477", "000008", "0", "2015/Apr/20 13:06", "Ideal Boilers", "Ideal", "INSTINCT", "30", "47-349-10", "2015", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "88.4", "79.8", "", "62.3", "", "2", "", "", "104", "1", "2", "152", "1", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "", "0035", "", "", "", "", "", "", "", "", "90.0", "96.9", "", "", "", "", "95.6"]} -{"pcdb_id": 17478, "brand_name": "Ideal", "model_name": "INSTINCT", "model_qualifier": "35", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 62.3, "output_kw_max": 24.2, "final_year_of_manufacture": null, "raw": ["017478", "000008", "0", "2015/Apr/20 13:07", "Ideal Boilers", "Ideal", "INSTINCT", "35", "47-349-11", "2015", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "88.4", "79.8", "", "62.3", "", "2", "", "", "104", "1", "2", "177", "1", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "", "0035", "", "", "", "", "", "", "", "", "89.8", "96.9", "", "", "", "", "95.6"]} -{"pcdb_id": 17479, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "9i System ErP", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 9.0, "final_year_of_manufacture": null, "raw": ["017479", "000035", "0", "2015/May/06 14:33", "Bosch Thermotechnology", "Worcester", "Greenstar", "9i System ErP", "41-406-21", "2015", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "9", "9", "", "", "89.1", "80.1", "", "58.5", "", "2", "", "", "102", "1", "2", "94", "1.7", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "8325", "", "", "", "", "", "", "", "", "88.3", "99.6", "", "", "", "", "97.4"]} -{"pcdb_id": 17480, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "12i System ErP LPG", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 12.0, "final_year_of_manufacture": null, "raw": ["017480", "000035", "0", "2017/May/15 15:31", "Bosch Thermotechnology", "Worcester", "Greenstar", "12i System ErP LPG", "41-406-24", "2015", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "12.0", "12.0", "", "", "89.1", "80.1", "", "58.5", "", "2", "0", "0", "102", "1", "2", "109", "1.7", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "8325", "", "", "", "", "", "", "", "", "89.2", "97.0", "", "", "", "", "95.5"]} -{"pcdb_id": 17481, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "12i System ErP", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 12.0, "final_year_of_manufacture": null, "raw": ["017481", "000035", "0", "2015/May/06 13:18", "Bosch Thermotechnology", "Worcester", "Greenstar", "12i System ErP", "41-406-23", "2015", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "12.0", "12.0", "", "", "89.1", "80.1", "", "58.5", "", "2", "", "", "102", "1", "2", "107", "1.7", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "8325", "", "", "", "", "", "", "", "", "88.3", "99.6", "", "", "", "", "97.4"]} -{"pcdb_id": 17482, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "15i System ErP LPG", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 15.0, "final_year_of_manufacture": null, "raw": ["017482", "000035", "0", "2017/May/15 15:31", "Bosch Thermotechnology", "Worcester", "Greenstar", "15i System ErP LPG", "41-406-26", "2015", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "15.0", "15.0", "", "", "88.4", "79.4", "", "58.0", "", "2", "0", "0", "102", "1", "2", "105", "1.7", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "8325", "", "", "", "", "", "", "", "", "89.4", "95.0", "", "", "", "", "94.0"]} -{"pcdb_id": 17483, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "15i System ErP", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 15.0, "final_year_of_manufacture": null, "raw": ["017483", "000035", "0", "2015/May/06 13:19", "Bosch Thermotechnology", "Worcester", "Greenstar", "15i System ErP", "41-406-25", "2015", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "15.0", "15.0", "", "", "89.0", "80.0", "", "58.4", "", "2", "", "", "102", "1", "2", "102", "1.7", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "8325", "", "", "", "", "", "", "", "", "87.9", "99.4", "", "", "", "", "97.2"]} -{"pcdb_id": 17484, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "18i System ErP LPG", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 18.0, "final_year_of_manufacture": null, "raw": ["017484", "000035", "0", "2017/May/15 15:31", "Bosch Thermotechnology", "Worcester", "Greenstar", "18i System ErP LPG", "41-406-28", "2015", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "18.0", "18.0", "", "", "88.4", "79.4", "", "58.0", "", "2", "0", "0", "102", "1", "2", "119", "1.7", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "8325", "", "", "", "", "", "", "", "", "89.4", "95.0", "", "", "", "", "94.0"]} -{"pcdb_id": 17485, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "18i System ErP", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 18.0, "final_year_of_manufacture": null, "raw": ["017485", "000035", "0", "2015/May/06 13:20", "Bosch Thermotechnology", "Worcester", "Greenstar", "18i System ErP", "41-406-27", "2015", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18.0", "18.0", "", "", "89.0", "80.0", "", "58.4", "", "2", "", "", "102", "1", "2", "117", "1.7", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "8325", "", "", "", "", "", "", "", "", "87.9", "99.4", "", "", "", "", "97.2"]} -{"pcdb_id": 17486, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "21i System ErP LPG", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 21.0, "final_year_of_manufacture": null, "raw": ["017486", "000035", "0", "2017/May/15 15:31", "Bosch Thermotechnology", "Worcester", "Greenstar", "21i System ErP LPG", "41-406-30", "2015", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "21.0", "21.0", "", "", "88.4", "79.4", "", "58.0", "", "2", "0", "0", "102", "1", "2", "107", "1.7", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "8325", "", "", "", "", "", "", "", "", "89.7", "95.0", "", "", "", "", "94.0"]} -{"pcdb_id": 17487, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "21i System ErP", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 21.0, "final_year_of_manufacture": null, "raw": ["017487", "000035", "0", "2015/May/06 13:21", "Bosch Thermotechnology", "Worcester", "Greenstar", "21i System ErP", "41-406-29", "2015", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "21.0", "21.0", "", "", "89.0", "80.0", "", "58.4", "", "2", "", "", "102", "1", "2", "102", "1.7", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "8325", "", "", "", "", "", "", "", "", "87.8", "99.5", "", "", "", "", "97.2"]} -{"pcdb_id": 17488, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "24i System ErP LPG", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 24.0, "final_year_of_manufacture": null, "raw": ["017488", "000035", "0", "2017/May/15 15:31", "Bosch Thermotechnology", "Worcester", "Greenstar", "24i System ErP LPG", "41-406-32", "2015", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "24", "24", "", "", "88.4", "79.4", "", "58.0", "", "2", "0", "0", "102", "1", "2", "109", "1.7", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "8325", "", "", "", "", "", "", "", "", "89.7", "95.0", "", "", "", "", "94.0"]} -{"pcdb_id": 17489, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "24i System ErP", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 24.0, "final_year_of_manufacture": null, "raw": ["017489", "000035", "0", "2015/May/06 13:21", "Bosch Thermotechnology", "Worcester", "Greenstar", "24i System ErP", "41-406-31", "2015", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24", "24", "", "", "89.0", "80.0", "", "58.4", "", "2", "", "", "102", "1", "2", "106", "1.7", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "8325", "", "", "", "", "", "", "", "", "87.8", "99.5", "", "", "", "", "97.2"]} -{"pcdb_id": 17490, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "27i System Compact ErP LPG", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 27.0, "final_year_of_manufacture": null, "raw": ["017490", "000035", "0", "2018/Jan/26 14:11", "Bosch Thermotechnology", "Worcester", "Greenstar", "27i System Compact ErP LPG", "41-406-59", "2015", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "27", "27", "", "", "89.2", "80.2", "", "58.6", "", "2", "0", "0", "102", "1", "2", "102", "1", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "8325", "", "", "", "", "", "", "", "", "90.2", "96.8", "", "", "", "", "95.5"]} -{"pcdb_id": 17491, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "27i System Compact ErP", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 27.0, "final_year_of_manufacture": null, "raw": ["017491", "000035", "0", "2015/Apr/15 14:33", "Bosch Thermotechnology", "Worcester", "Greenstar", "27i System Compact ErP", "41-406-58", "2015", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "27", "27", "", "", "88.3", "79.3", "", "57.9", "", "2", "", "", "102", "1", "2", "102", "1", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "8325", "", "", "", "", "", "", "", "", "88.2", "97.4", "", "", "", "", "95.7"]} -{"pcdb_id": 17492, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "30i System Compact ErP LPG", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 30.0, "final_year_of_manufacture": null, "raw": ["017492", "000035", "0", "2018/Jan/26 14:11", "Bosch Thermotechnology", "Worcester", "Greenstar", "30i System Compact ErP LPG", "41-406-61", "2015", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "30", "30", "", "", "89.2", "80.2", "", "58.6", "", "2", "0", "0", "102", "1", "2", "109", "1", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "8325", "", "", "", "", "", "", "", "", "90.2", "96.8", "", "", "", "", "95.5"]} -{"pcdb_id": 17493, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "30i System Compact ErP", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 30.0, "final_year_of_manufacture": null, "raw": ["017493", "000035", "0", "2015/Apr/15 14:40", "Bosch Thermotechnology", "Worcester", "Greenstar", "30i System Compact ErP", "41-406-60", "2015", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "30", "30", "", "", "88.3", "79.3", "", "57.9", "", "2", "", "", "102", "1", "2", "109", "1", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "8325", "", "", "", "", "", "", "", "", "88.2", "97.4", "", "", "", "", "95.7"]} -{"pcdb_id": 17495, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "27Ri Compact ErP LPG", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 27.0, "final_year_of_manufacture": null, "raw": ["017495", "000035", "0", "2018/Jan/26 14:11", "Bosch Thermotechnology", "Worcester", "Greenstar", "27Ri Compact ErP LPG", "41-406-55", "2015", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "27", "27", "", "", "89.2", "80.2", "", "58.6", "", "2", "0", "0", "102", "1", "2", "33", "1", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0325", "", "", "", "", "", "", "", "", "90.2", "96.8", "", "", "", "", "95.5"]} -{"pcdb_id": 17496, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "27Ri Compact ErP", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 27.0, "final_year_of_manufacture": null, "raw": ["017496", "000035", "0", "2018/Jan/26 14:11", "Bosch Thermotechnology", "Worcester", "Greenstar", "27Ri Compact ErP", "41-406-54", "2015", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "27", "27", "", "", "88.3", "79.3", "", "57.9", "", "2", "", "", "102", "1", "2", "34", "1", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0325", "", "", "", "", "", "", "", "", "88.2", "97.4", "", "", "", "", "95.7"]} -{"pcdb_id": 17497, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "30Ri Compact ErP LPG", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 30.0, "final_year_of_manufacture": null, "raw": ["017497", "000035", "0", "2018/Jan/26 14:11", "Bosch Thermotechnology", "Worcester", "Greenstar", "30Ri Compact ErP LPG", "41-406-57", "2015", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "30", "30", "", "", "89.2", "80.2", "", "58.6", "", "2", "0", "0", "102", "1", "2", "39", "1", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0325", "", "", "", "", "", "", "", "", "90.2", "96.8", "", "", "", "", "95.5"]} -{"pcdb_id": 17498, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "30Ri Compact ErP", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 30.0, "final_year_of_manufacture": null, "raw": ["017498", "000035", "0", "2018/Jan/26 14:11", "Bosch Thermotechnology", "Worcester", "Greenstar", "30Ri Compact ErP", "41-406-56", "2015", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "30", "30", "", "", "88.3", "79.3", "", "57.9", "", "2", "", "", "102", "1", "2", "40", "1", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0325", "", "", "", "", "", "", "", "", "88.2", "97.4", "", "", "", "", "95.7"]} -{"pcdb_id": 17500, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "25Si Compact ErP LPG", "winter_efficiency_pct": 89.8, "summer_efficiency_pct": 88.8, "comparative_hot_water_efficiency_pct": 75.8, "output_kw_max": 24.0, "final_year_of_manufacture": null, "raw": ["017500", "000035", "0", "2020/Jul/17 10:33", "Bosch Thermotechnology", "Worcester", "Greenstar", "25Si Compact ErP LPG", "47-406-74", "2015", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "89.8", "88.8", "", "75.8", "", "2", "0", "", "104", "1", "2", "97", "1", "0", "", "", "", "0", "", "", "", "", "1", "7.1", "0.09", "0.0013", "0.99038", "", "", "", "", "", "1", "1", "", "8325", "", "", "", "", "", "", "", "", "90.4", "98.2", "", "", "", "", "96.7"]} -{"pcdb_id": 17501, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "25Si Compact ErP", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 87.0, "comparative_hot_water_efficiency_pct": 74.7, "output_kw_max": 24.0, "final_year_of_manufacture": null, "raw": ["017501", "000035", "0", "2020/Jul/17 10:39", "Bosch Thermotechnology", "Worcester", "Greenstar", "25Si Compact ErP", "47-406-73", "2015", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "89.2", "87.0", "", "74.7", "", "2", "", "", "104", "1", "2", "97", "1", "0", "", "", "", "0", "", "", "", "", "1", "7.051", "0.08", "0.0015", "0.95138", "", "", "", "", "", "1", "1", "", "8325", "", "", "", "", "", "", "", "", "88.8", "99.6", "", "", "", "", "97.5"]} -{"pcdb_id": 17502, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "30Si Compact ErP LPG", "winter_efficiency_pct": 89.8, "summer_efficiency_pct": 88.8, "comparative_hot_water_efficiency_pct": 75.2, "output_kw_max": 24.0, "final_year_of_manufacture": null, "raw": ["017502", "000035", "0", "2020/Jul/17 11:16", "Bosch Thermotechnology", "Worcester", "Greenstar", "30Si Compact ErP LPG", "47-406-76", "2015", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "89.8", "88.8", "", "75.2", "", "2", "0", "", "104", "1", "2", "97", "1", "0", "", "", "", "0", "", "", "", "", "1", "7.16", "0.089", "0.0013", "1.04824", "", "", "", "", "", "1", "1", "", "8325", "", "", "", "", "", "", "", "", "90.4", "98.2", "", "", "", "", "96.7"]} -{"pcdb_id": 17503, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "30Si Compact ErP", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 87.0, "comparative_hot_water_efficiency_pct": 74.2, "output_kw_max": 24.0, "final_year_of_manufacture": null, "raw": ["017503", "000035", "0", "2021/Nov/17 12:53", "Bosch Thermotechnology", "Worcester", "Greenstar", "30Si Compact ErP", "47-406-75", "2015", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "89.2", "87.0", "", "74.2", "", "2", "", "", "104", "1", "2", "97", "1", "0", "", "", "", "0", "", "", "", "", "1", "7.102", "0.078", "0.0019", "0.99839", "", "", "", "", "", "1", "1", "", "8325", "", "", "", "", "", "", "", "", "88.8", "99.6", "", "", "", "", "97.5"]} -{"pcdb_id": 17504, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "25i ErP LPG", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 88.6, "comparative_hot_water_efficiency_pct": 71.1, "output_kw_max": 24.0, "final_year_of_manufacture": null, "raw": ["017504", "000035", "0", "2021/Nov/17 12:53", "Bosch Thermotechnology", "Worcester", "Greenstar", "25i ErP LPG", "47-406-61", "2015", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24.0", "24.0", "", "", "88.5", "88.6", "", "71.1", "", "2", "0", "0", "104", "1", "2", "109", "1.7", "0", "", "", "", "0", "", "", "", "", "1", "7.569", "0.093", "0.0015", "1.42427", "", "", "", "", "", "", "", "", "8325", "", "", "", "", "", "", "", "", "89.8", "95.0", "", "", "", "", "94.0"]} -{"pcdb_id": 17505, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "25i ErP", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 86.6, "comparative_hot_water_efficiency_pct": 73.2, "output_kw_max": 24.0, "final_year_of_manufacture": null, "raw": ["017505", "000035", "0", "2020/Jul/17 11:37", "Bosch Thermotechnology", "Worcester", "Greenstar", "25i ErP", "47-406-60", "2015", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "89.0", "86.6", "", "73.2", "", "2", "", "", "104", "1", "2", "106", "1.7", "0", "", "", "", "0", "", "", "", "", "1", "7.19", "0.073", "0.0016", "1.05659", "", "", "", "", "", "1", "1", "", "8325", "", "", "", "", "", "", "", "", "87.8", "99.5", "", "", "", "", "97.2"]} -{"pcdb_id": 17506, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "30i ErP LPG", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 88.6, "comparative_hot_water_efficiency_pct": 69.7, "output_kw_max": 24.0, "final_year_of_manufacture": null, "raw": ["017506", "000035", "0", "2022/Jan/05 09:48", "Bosch Thermotechnology", "Worcester", "Greenstar", "30i ErP LPG", "47-406-63", "2015", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24.0", "24.0", "", "", "88.5", "88.6", "", "69.7", "", "2", "0", "0", "104", "1", "2", "109", "1.7", "0", "", "", "", "0", "", "", "", "", "1", "7.727", "0.096", "0.0015", "1.57614", "", "", "", "", "", "", "", "", "8325", "", "", "", "", "", "", "", "", "89.8", "95.0", "", "", "", "", "94.0"]} -{"pcdb_id": 17507, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "30i ErP", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 86.6, "comparative_hot_water_efficiency_pct": 72.1, "output_kw_max": 24.0, "final_year_of_manufacture": null, "raw": ["017507", "000035", "0", "2020/Jul/17 11:55", "Bosch Thermotechnology", "Worcester", "Greenstar", "30i ErP", "47-406-62", "2015", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "89.0", "86.6", "", "72.1", "", "2", "", "", "104", "1", "2", "106", "1.7", "0", "", "", "", "0", "", "", "", "", "1", "7.304", "0.076", "0.0015", "1.16717", "", "", "", "", "", "1", "1", "", "8325", "", "", "", "", "", "", "", "", "87.8", "99.5", "", "", "", "", "97.2"]} -{"pcdb_id": 17508, "brand_name": "Worcester", "model_name": "533 Compact ErP", "model_qualifier": "", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 87.0, "comparative_hot_water_efficiency_pct": 74.8, "output_kw_max": 24.0, "final_year_of_manufacture": 2018, "raw": ["017508", "000035", "0", "2020/Sep/08 10:44", "Bosch Thermotechnology", "Worcester", "533 Compact ErP", "", "47-406-83", "2015", "2018", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "89.2", "87.0", "", "74.8", "", "2", "", "", "104", "1", "2", "97", "1", "0", "", "", "", "0", "", "", "", "", "1", "7.042", "0.079", "0.0015", "0.94279", "", "", "", "", "", "1", "1", "", "0005", "", "", "", "", "", "", "", "", "88.8", "99.6", "", "", "", "", "97.5"]} -{"pcdb_id": 17509, "brand_name": "Worcester", "model_name": "535 Compact ErP", "model_qualifier": "", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 87.0, "comparative_hot_water_efficiency_pct": 74.2, "output_kw_max": 24.0, "final_year_of_manufacture": 2018, "raw": ["017509", "000035", "0", "2020/Sep/08 10:45", "Bosch Thermotechnology", "Worcester", "535 Compact ErP", "", "47-406-84", "2015", "2018", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "89.2", "87.0", "", "74.2", "", "2", "", "", "104", "1", "2", "97", "1", "0", "", "", "", "0", "", "", "", "", "1", "7.095", "0.079", "0.0015", "0.99382", "", "", "", "", "", "1", "1", "", "0005", "", "", "", "", "", "", "", "", "88.8", "99.6", "", "", "", "", "97.5"]} -{"pcdb_id": 17510, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "28CDi Compact ErP LPG", "winter_efficiency_pct": 89.8, "summer_efficiency_pct": 88.8, "comparative_hot_water_efficiency_pct": 74.8, "output_kw_max": 24.0, "final_year_of_manufacture": null, "raw": ["017510", "000035", "0", "2020/Jul/17 11:59", "Bosch Thermotechnology", "Worcester", "Greenstar", "28CDi Compact ErP LPG", "47-406-78", "2015", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "89.8", "88.8", "", "74.8", "", "2", "0", "", "104", "1", "2", "97", "1", "0", "", "", "", "0", "", "", "", "", "1", "7.2", "0.087", "0.0014", "1.08665", "", "", "", "", "", "1", "1", "", "8325", "", "", "", "", "", "", "", "", "90.4", "98.2", "", "", "", "", "96.7"]} -{"pcdb_id": 17511, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "28CDi Compact ErP", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 87.2, "comparative_hot_water_efficiency_pct": 74.9, "output_kw_max": 24.0, "final_year_of_manufacture": null, "raw": ["017511", "000035", "0", "2020/Jul/27 16:00", "Bosch Thermotechnology", "Worcester", "Greenstar", "28CDi Compact ErP", "47-406-77", "2015", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "89.2", "87.2", "", "74.9", "", "2", "", "", "104", "1", "2", "97", "1", "0", "", "", "", "0", "", "", "", "", "2", "7.032", "0.078", "0.0015", "0.93299", "13.056", "0.102", "0.0023", "0.81383", "-0.00001", "1", "1", "", "8325", "", "", "", "", "", "", "", "", "88.8", "99.6", "", "", "", "", "97.5"]} -{"pcdb_id": 17512, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "32CDi Compact ErP LPG", "winter_efficiency_pct": 89.8, "summer_efficiency_pct": 88.8, "comparative_hot_water_efficiency_pct": 73.7, "output_kw_max": 24.0, "final_year_of_manufacture": null, "raw": ["017512", "000035", "0", "2020/Jul/17 12:04", "Bosch Thermotechnology", "Worcester", "Greenstar", "32CDi Compact ErP LPG", "47-406-80", "2015", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "89.8", "88.8", "", "73.7", "", "2", "0", "", "104", "1", "2", "97", "1", "0", "", "", "", "0", "", "", "", "", "1", "7.3", "0.089", "0.0007", "1.18698", "", "", "", "", "", "1", "1", "", "8325", "", "", "", "", "", "", "", "", "90.4", "98.2", "", "", "", "", "96.7"]} -{"pcdb_id": 17513, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "32CDi Compact ErP", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 87.2, "comparative_hot_water_efficiency_pct": 75.0, "output_kw_max": 24.0, "final_year_of_manufacture": null, "raw": ["017513", "000035", "0", "2020/Jul/27 16:09", "Bosch Thermotechnology", "Worcester", "Greenstar", "32CDi Compact ErP", "47-406-79", "2015", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "89.2", "87.2", "", "75.0", "", "2", "", "", "104", "1", "2", "97", "1", "0", "", "", "", "0", "", "", "", "", "2", "7.024", "0.08", "0.0027", "0.91849", "13.021", "0.103", "0.001", "0.80367", "0.00002", "1", "1", "", "8325", "", "", "", "", "", "", "", "", "88.8", "99.6", "", "", "", "", "97.5"]} -{"pcdb_id": 17514, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "36CDi Compact ErP LPG", "winter_efficiency_pct": 89.8, "summer_efficiency_pct": 88.8, "comparative_hot_water_efficiency_pct": 73.4, "output_kw_max": 24.0, "final_year_of_manufacture": null, "raw": ["017514", "000035", "0", "2020/Jul/17 12:20", "Bosch Thermotechnology", "Worcester", "Greenstar", "36CDi Compact ErP LPG", "47-406-82", "2015", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "89.8", "88.8", "", "73.4", "", "2", "0", "", "104", "1", "2", "97", "1", "0", "", "", "", "0", "", "", "", "", "1", "7.33", "0.088", "0.002", "1.208", "", "", "", "", "", "1", "1", "", "8325", "", "", "", "", "", "", "", "", "90.4", "98.2", "", "", "", "", "96.7"]} -{"pcdb_id": 17515, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "36CDi Compact ErP", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 87.9, "comparative_hot_water_efficiency_pct": 74.7, "output_kw_max": 24.0, "final_year_of_manufacture": null, "raw": ["017515", "000035", "0", "2020/Jul/27 16:20", "Bosch Thermotechnology", "Worcester", "Greenstar", "36CDi Compact ErP", "47-406-81", "2015", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "89.2", "87.9", "", "74.7", "", "2", "", "", "104", "1", "2", "97", "1", "0", "", "", "", "0", "", "", "", "", "2", "7.049", "0.086", "0.0017", "0.94834", "13.009", "0.105", "0.001", "0.88074", "0.00001", "1", "1", "", "8325", "", "", "", "", "", "", "", "", "88.8", "99.6", "", "", "", "", "97.5"]} -{"pcdb_id": 17516, "brand_name": "Worcester", "model_name": "Greenstar Heatslave II External", "model_qualifier": "12/18 ErP", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 82.2, "comparative_hot_water_efficiency_pct": 44.8, "output_kw_max": 18.0, "final_year_of_manufacture": 2018, "raw": ["017516", "000035", "0", "2024/Jan/31 10:17", "Bosch Thermotechnology", "Worcester", "Greenstar Heatslave II External", "12/18 ErP", "", "2015", "2018", "4", "1", "2", "2", "0", "", "", "2", "2", "1", "12", "18", "", "", "88.3", "82.2", "", "44.8", "", "2", "", "", "203", "1", "1", "194", "1.7", "1", "1", "", "42", "0", "25", "1", "84", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0123", "", "", "", "", "", "", "", "", "91.1", "95.4", "", "", "", "", "94.6"]} -{"pcdb_id": 17517, "brand_name": "Worcester", "model_name": "Greenstar Heatslave II External", "model_qualifier": "18/25 ErP", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 82.0, "comparative_hot_water_efficiency_pct": 44.7, "output_kw_max": 25.0, "final_year_of_manufacture": 2018, "raw": ["017517", "000035", "0", "2024/Jan/31 10:17", "Bosch Thermotechnology", "Worcester", "Greenstar Heatslave II External", "18/25 ErP", "", "2015", "2018", "4", "1", "2", "2", "0", "", "", "2", "2", "1", "18", "25", "", "", "88.1", "82.0", "", "44.7", "", "2", "", "", "203", "1", "1", "194", "1.7", "1", "1", "", "42", "0", "25", "1", "86", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0123", "", "", "", "", "", "", "", "", "90.9", "95.1", "", "", "", "", "94.3"]} -{"pcdb_id": 17518, "brand_name": "Worcester", "model_name": "Greenstar Heatslave II External", "model_qualifier": "25/32 ErP", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 81.8, "comparative_hot_water_efficiency_pct": 44.6, "output_kw_max": 32.0, "final_year_of_manufacture": 2018, "raw": ["017518", "000035", "0", "2024/Jan/31 10:17", "Bosch Thermotechnology", "Worcester", "Greenstar Heatslave II External", "25/32 ErP", "", "2015", "2018", "4", "1", "2", "2", "0", "", "", "2", "2", "1", "25", "32", "", "", "87.9", "81.8", "", "44.6", "", "2", "", "", "203", "1", "1", "233", "1.7", "1", "1", "", "42", "0", "25", "1", "88", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0123", "", "", "", "", "", "", "", "", "91.4", "94.3", "", "", "", "", "93.7"]} -{"pcdb_id": 17519, "brand_name": "Worcester", "model_name": "Greenstar Heatslave II", "model_qualifier": "12/18 ErP", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 82.2, "comparative_hot_water_efficiency_pct": 44.8, "output_kw_max": 18.0, "final_year_of_manufacture": 2018, "raw": ["017519", "000035", "0", "2024/Jan/31 10:17", "Bosch Thermotechnology", "Worcester", "Greenstar Heatslave II", "12/18 ErP", "", "2015", "2018", "4", "1", "1", "2", "0", "", "", "2", "3", "1", "12", "18", "", "", "88.3", "82.2", "", "44.8", "", "2", "", "", "203", "1", "1", "194", "1.7", "1", "1", "", "42", "0", "25", "1", "84", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0123", "", "", "", "", "", "", "", "", "91.1", "95.4", "", "", "", "", "94.6"]} -{"pcdb_id": 17520, "brand_name": "Worcester", "model_name": "Greenstar Heatslave II", "model_qualifier": "18/25 ErP", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 82.0, "comparative_hot_water_efficiency_pct": 44.7, "output_kw_max": 25.0, "final_year_of_manufacture": 2018, "raw": ["017520", "000035", "0", "2024/Jan/31 10:17", "Bosch Thermotechnology", "Worcester", "Greenstar Heatslave II", "18/25 ErP", "", "2015", "2018", "4", "1", "1", "2", "0", "", "", "2", "3", "1", "18", "25", "", "", "88.1", "82.0", "", "44.7", "", "2", "", "", "203", "1", "1", "209", "1.7", "1", "1", "", "42", "0", "25", "1", "86", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0123", "", "", "", "", "", "", "", "", "90.9", "95.1", "", "", "", "", "94.3"]} -{"pcdb_id": 17521, "brand_name": "Worcester", "model_name": "Greenstar Heatslave II", "model_qualifier": "25/32 ErP", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 81.8, "comparative_hot_water_efficiency_pct": 44.6, "output_kw_max": 32.0, "final_year_of_manufacture": 2018, "raw": ["017521", "000035", "0", "2024/Jan/31 10:17", "Bosch Thermotechnology", "Worcester", "Greenstar Heatslave II", "25/32 ErP", "", "2015", "2018", "4", "1", "1", "2", "0", "", "", "2", "3", "1", "25", "32", "", "", "87.9", "81.8", "", "44.6", "", "2", "", "", "203", "1", "1", "233", "1.7", "1", "1", "", "42", "0", "25", "1", "88", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0123", "", "", "", "", "", "", "", "", "91.4", "94.3", "", "", "", "", "93.7"]} -{"pcdb_id": 17522, "brand_name": "Worcester", "model_name": "Greenstar Danesmoor", "model_qualifier": "12/18 ErP", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 58.8, "output_kw_max": 18.0, "final_year_of_manufacture": 2018, "raw": ["017522", "000035", "0", "2020/Sep/08 10:45", "Bosch Thermotechnology", "Worcester", "Greenstar Danesmoor", "12/18 ErP", "", "2015", "2018", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "12", "18", "", "", "88.3", "80.5", "", "58.8", "", "2", "", "", "201", "1", "1", "143", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.1", "95.4", "", "", "", "", "94.6"]} -{"pcdb_id": 17524, "brand_name": "Worcester", "model_name": "Greenstar Danesmoor", "model_qualifier": "18/25 ErP", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 58.7, "output_kw_max": 25.0, "final_year_of_manufacture": 2018, "raw": ["017524", "000035", "0", "2020/Sep/08 10:46", "Bosch Thermotechnology", "Worcester", "Greenstar Danesmoor", "18/25 ErP", "", "2015", "2018", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "18", "25", "", "", "88.1", "80.3", "", "58.7", "", "2", "", "", "201", "1", "1", "160", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.9", "95.1", "", "", "", "", "94.3"]} -{"pcdb_id": 17525, "brand_name": "Worcester", "model_name": "Greenstar Danesmoor", "model_qualifier": "25/32 ErP", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 32.0, "final_year_of_manufacture": 2018, "raw": ["017525", "000035", "0", "2020/Sep/08 10:46", "Bosch Thermotechnology", "Worcester", "Greenstar Danesmoor", "25/32 ErP", "", "2015", "2018", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "25", "32", "", "", "87.9", "80.1", "", "58.5", "", "2", "", "", "201", "1", "1", "160", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.4", "94.3", "", "", "", "", "93.7"]} -{"pcdb_id": 17526, "brand_name": "Worcester", "model_name": "Greenstar Danesmoor External", "model_qualifier": "12/18 ErP", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 58.8, "output_kw_max": 18.0, "final_year_of_manufacture": 2018, "raw": ["017526", "000035", "0", "2020/Sep/08 10:46", "Bosch Thermotechnology", "Worcester", "Greenstar Danesmoor External", "12/18 ErP", "", "2015", "2018", "4", "1", "2", "1", "0", "", "", "2", "2", "1", "12", "18", "", "", "88.3", "80.5", "", "58.8", "", "2", "", "", "201", "1", "1", "143", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.1", "95.4", "", "", "", "", "94.6"]} -{"pcdb_id": 17527, "brand_name": "Worcester", "model_name": "Greenstar Danesmoor External", "model_qualifier": "18/25 ErP", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 58.7, "output_kw_max": 25.0, "final_year_of_manufacture": 2018, "raw": ["017527", "000035", "0", "2020/Sep/08 10:46", "Bosch Thermotechnology", "Worcester", "Greenstar Danesmoor External", "18/25 ErP", "", "2015", "2018", "4", "1", "2", "1", "0", "", "", "2", "2", "1", "18", "25", "", "", "88.1", "80.3", "", "58.7", "", "2", "", "", "201", "1", "1", "160", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.9", "95.1", "", "", "", "", "94.3"]} -{"pcdb_id": 17528, "brand_name": "Worcester", "model_name": "Greenstar Danesmoor External", "model_qualifier": "25/32 ErP", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 32.0, "final_year_of_manufacture": 2018, "raw": ["017528", "000035", "0", "2020/Sep/08 10:46", "Bosch Thermotechnology", "Worcester", "Greenstar Danesmoor External", "25/32 ErP", "", "2015", "2018", "4", "1", "2", "1", "0", "", "", "2", "2", "1", "25", "32", "", "", "87.9", "80.1", "", "58.5", "", "2", "", "", "201", "1", "1", "160", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.4", "94.3", "", "", "", "", "93.7"]} -{"pcdb_id": 17529, "brand_name": "Worcester", "model_name": "Greenstar Danesmoor Utility", "model_qualifier": "12/18 ErP", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 58.8, "output_kw_max": 18.0, "final_year_of_manufacture": 2018, "raw": ["017529", "000035", "0", "2020/Sep/08 10:46", "Bosch Thermotechnology", "Worcester", "Greenstar Danesmoor Utility", "12/18 ErP", "", "2015", "2018", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "12", "18", "", "", "88.3", "80.5", "", "58.8", "", "2", "", "", "201", "1", "1", "143", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.1", "95.4", "", "", "", "", "94.6"]} -{"pcdb_id": 17530, "brand_name": "Worcester", "model_name": "Greenstar Danesmoor Utility", "model_qualifier": "18/25 ErP", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 58.7, "output_kw_max": 25.0, "final_year_of_manufacture": 2018, "raw": ["017530", "000035", "0", "2020/Sep/08 10:47", "Bosch Thermotechnology", "Worcester", "Greenstar Danesmoor Utility", "18/25 ErP", "", "2015", "2018", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "18", "25", "", "", "88.1", "80.3", "", "58.7", "", "2", "", "", "201", "1", "1", "160", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.9", "95.1", "", "", "", "", "94.3"]} -{"pcdb_id": 17531, "brand_name": "Worcester", "model_name": "Greenstar Danesmoor Utility", "model_qualifier": "25/32 ErP", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 32.0, "final_year_of_manufacture": 2018, "raw": ["017531", "000035", "0", "2020/Sep/08 10:47", "Bosch Thermotechnology", "Worcester", "Greenstar Danesmoor Utility", "25/32 ErP", "", "2015", "2018", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "25", "32", "", "", "87.9", "80.1", "", "58.5", "", "2", "", "", "201", "1", "1", "160", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.4", "94.3", "", "", "", "", "93.7"]} -{"pcdb_id": 17532, "brand_name": "Worcester", "model_name": "Greenstar Danesmoor System", "model_qualifier": "12/18 ErP", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 58.8, "output_kw_max": 18.0, "final_year_of_manufacture": 2018, "raw": ["017532", "000035", "0", "2020/Sep/08 10:47", "Bosch Thermotechnology", "Worcester", "Greenstar Danesmoor System", "12/18 ErP", "", "2015", "2018", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "12", "18", "", "", "88.3", "80.5", "", "58.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.1", "95.4", "", "", "", "", "94.6"]} -{"pcdb_id": 17533, "brand_name": "Worcester", "model_name": "Greenstar Danesmoor System", "model_qualifier": "18/25 ErP", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 58.7, "output_kw_max": 25.0, "final_year_of_manufacture": 2018, "raw": ["017533", "000035", "0", "2020/Sep/08 10:47", "Bosch Thermotechnology", "Worcester", "Greenstar Danesmoor System", "18/25 ErP", "", "2015", "2018", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "18", "25", "", "", "88.1", "80.3", "", "58.7", "", "2", "", "", "201", "1", "1", "208", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.9", "95.1", "", "", "", "", "94.3"]} -{"pcdb_id": 17534, "brand_name": "Worcester", "model_name": "Greenstar Danesmoor System", "model_qualifier": "25/32 ErP", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 32.0, "final_year_of_manufacture": 2018, "raw": ["017534", "000035", "0", "2020/Sep/08 10:47", "Bosch Thermotechnology", "Worcester", "Greenstar Danesmoor System", "25/32 ErP", "", "2015", "2018", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "25", "32", "", "", "87.9", "80.1", "", "58.5", "", "2", "", "", "201", "1", "1", "208", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.4", "94.3", "", "", "", "", "93.7"]} -{"pcdb_id": 17535, "brand_name": "Worcester", "model_name": "Greenstar Danesmoor System External", "model_qualifier": "12/18 ErP", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 58.8, "output_kw_max": 18.0, "final_year_of_manufacture": 2018, "raw": ["017535", "000035", "0", "2020/Sep/08 10:47", "Bosch Thermotechnology", "Worcester", "Greenstar Danesmoor System External", "12/18 ErP", "", "2015", "2018", "4", "1", "2", "1", "0", "", "", "2", "2", "1", "12", "18", "", "", "88.3", "80.5", "", "58.8", "", "2", "", "", "201", "1", "1", "191", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.1", "95.4", "", "", "", "", "94.6"]} -{"pcdb_id": 17536, "brand_name": "Worcester", "model_name": "Greenstar Danesmoor System External", "model_qualifier": "18/25 ErP", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 58.7, "output_kw_max": 25.0, "final_year_of_manufacture": 2018, "raw": ["017536", "000035", "0", "2020/Sep/08 10:47", "Bosch Thermotechnology", "Worcester", "Greenstar Danesmoor System External", "18/25 ErP", "", "2015", "2018", "4", "1", "2", "1", "0", "", "", "2", "2", "1", "18", "25", "", "", "88.1", "80.3", "", "58.7", "", "2", "", "", "201", "1", "1", "208", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.9", "95.1", "", "", "", "", "94.3"]} -{"pcdb_id": 17537, "brand_name": "Worcester", "model_name": "Greenstar Danesmoor System External", "model_qualifier": "25/32 ErP", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 32.0, "final_year_of_manufacture": 2018, "raw": ["017537", "000035", "0", "2020/Sep/08 10:47", "Bosch Thermotechnology", "Worcester", "Greenstar Danesmoor System External", "25/32 ErP", "", "2015", "2018", "4", "1", "2", "1", "0", "", "", "2", "2", "1", "25", "32", "", "", "87.9", "80.1", "", "58.5", "", "2", "", "", "201", "1", "1", "208", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.4", "94.3", "", "", "", "", "93.7"]} -{"pcdb_id": 17538, "brand_name": "Worcester", "model_name": "Greenstar Danesmoor System Utility", "model_qualifier": "12/18 ErP", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 58.8, "output_kw_max": 18.0, "final_year_of_manufacture": 2018, "raw": ["017538", "000035", "0", "2020/Sep/08 10:47", "Bosch Thermotechnology", "Worcester", "Greenstar Danesmoor System Utility", "12/18 ErP", "", "2015", "2018", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "12", "18", "", "", "88.3", "80.5", "", "58.8", "", "2", "", "", "201", "1", "1", "191", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.1", "95.4", "", "", "", "", "94.6"]} -{"pcdb_id": 17539, "brand_name": "Worcester", "model_name": "Greenstar Danesmoor System Utility", "model_qualifier": "18/25 ErP", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 58.7, "output_kw_max": 25.0, "final_year_of_manufacture": 2018, "raw": ["017539", "000035", "0", "2020/Sep/08 10:47", "Bosch Thermotechnology", "Worcester", "Greenstar Danesmoor System Utility", "18/25 ErP", "", "2015", "2018", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "18", "25", "", "", "88.1", "80.3", "", "58.7", "", "2", "", "", "201", "1", "1", "208", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.9", "95.1", "", "", "", "", "94.3"]} -{"pcdb_id": 17540, "brand_name": "Worcester", "model_name": "Greenstar Danesmoor System Utility", "model_qualifier": "25/32 ErP", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 32.0, "final_year_of_manufacture": 2018, "raw": ["017540", "000035", "0", "2020/Sep/08 10:48", "Bosch Thermotechnology", "Worcester", "Greenstar Danesmoor System Utility", "25/32 ErP", "", "2015", "2018", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "25", "32", "", "", "87.9", "80.1", "", "58.5", "", "2", "", "", "201", "1", "1", "208", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.4", "94.3", "", "", "", "", "93.7"]} -{"pcdb_id": 17541, "brand_name": "Worcester", "model_name": "Greenstar Danesmoor Utility", "model_qualifier": "32/50 ErP", "winter_efficiency_pct": 87.7, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 50.0, "final_year_of_manufacture": 2019, "raw": ["017541", "000035", "0", "2020/Sep/08 10:48", "Bosch Thermotechnology", "Worcester", "Greenstar Danesmoor Utility", "32/50 ErP", "", "2015", "2019", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "32", "50", "", "", "87.7", "79.9", "", "58.4", "", "2", "", "", "201", "1", "1", "188", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.0", "94.0", "", "", "", "", "93.4"]} -{"pcdb_id": 17542, "brand_name": "Worcester", "model_name": "Greenstar Danesmoor Utility", "model_qualifier": "50/70 ErP", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 70.0, "final_year_of_manufacture": 2019, "raw": ["017542", "000035", "0", "2020/Sep/08 10:48", "Bosch Thermotechnology", "Worcester", "Greenstar Danesmoor Utility", "50/70 ErP", "", "2015", "2019", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "50", "70", "", "", "87.9", "80.1", "", "58.5", "", "2", "", "", "201", "1", "1", "176", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.6", "94.3", "", "", "", "", "93.8"]} -{"pcdb_id": 17543, "brand_name": "Ravenheat", "model_name": "HE 80(T)", "model_qualifier": "Natural Gas", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 86.6, "comparative_hot_water_efficiency_pct": 76.8, "output_kw_max": 19.5, "final_year_of_manufacture": null, "raw": ["017543", "000026", "0", "2015/May/06 11:53", "Ravenheat Manufacturing", "Ravenheat", "HE 80(T)", "Natural Gas", "", "2015", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "19.5", "19.5", "", "", "88.0", "86.6", "", "76.8", "", "2", "", "", "104", "1", "2", "110", "3", "0", "", "", "", "0", "", "", "", "", "1", "6.859", "0.134", "0.0104", "0.68941", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "96.9", "", "", "", "", "95.2"]} -{"pcdb_id": 17544, "brand_name": "Ravenheat", "model_name": "HE 90(T)", "model_qualifier": "Natural gas", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 86.6, "comparative_hot_water_efficiency_pct": 69.1, "output_kw_max": 23.9, "final_year_of_manufacture": null, "raw": ["017544", "000026", "0", "2015/May/06 11:53", "Ravenheat Manufacturing", "Ravenheat", "HE 90(T)", "Natural gas", "", "2015", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "23.9", "23.9", "", "", "88.1", "86.6", "", "69.1", "", "2", "", "", "104", "1", "2", "160", "3", "0", "", "", "", "0", "", "", "", "", "1", "7.618", "0.129", "0.0065", "1.44231", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "97.1", "", "", "", "", "95.4"]} -{"pcdb_id": 17545, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "12Ri ErP LPG", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 12.0, "final_year_of_manufacture": 2018, "raw": ["017545", "000035", "0", "2020/Sep/08 10:48", "Bosch Thermotechnology", "Worcester", "Greenstar", "12Ri ErP LPG", "41-406-42", "2015", "2018", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "12", "12", "", "", "88.3", "79.3", "", "57.9", "", "2", "0", "0", "102", "1", "2", "36", "6.2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.5", "94.8", "", "", "", "", "93.8"]} -{"pcdb_id": 17546, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "12Ri ErP", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 12.0, "final_year_of_manufacture": 2018, "raw": ["017546", "000035", "0", "2020/Sep/08 10:48", "Bosch Thermotechnology", "Worcester", "Greenstar", "12Ri ErP", "41-406-41", "2015", "2018", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "12", "12", "", "", "88.1", "79.1", "", "57.7", "", "2", "", "", "102", "1", "2", "37", "6.2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "97.0", "", "", "", "", "95.3"]} -{"pcdb_id": 17547, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "15Ri ErP LPG", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 15.0, "final_year_of_manufacture": 2018, "raw": ["017547", "000035", "0", "2020/Sep/08 10:48", "Bosch Thermotechnology", "Worcester", "Greenstar", "15Ri ErP LPG", "41-406-44", "2015", "2018", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "15", "15", "", "", "88.4", "79.4", "", "58.0", "", "2", "0", "0", "102", "1", "2", "48", "6.2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.0", "95.0", "", "", "", "", "94.0"]} -{"pcdb_id": 17548, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "15Ri ErP", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 15.0, "final_year_of_manufacture": 2018, "raw": ["017548", "000035", "0", "2020/Sep/08 10:48", "Bosch Thermotechnology", "Worcester", "Greenstar", "15Ri ErP", "41-406-43", "2015", "2018", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "15", "15", "", "", "88.1", "79.1", "", "57.7", "", "2", "", "", "102", "1", "2", "50", "6.2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "97.0", "", "", "", "", "95.3"]} -{"pcdb_id": 17549, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "18Ri ErP LPG", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 18.0, "final_year_of_manufacture": 2018, "raw": ["017549", "000035", "0", "2020/Sep/08 10:48", "Bosch Thermotechnology", "Worcester", "Greenstar", "18Ri ErP LPG", "41-406-46", "2015", "2018", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "18.0", "18.0", "", "", "88.5", "79.5", "", "58.1", "", "2", "0", "0", "102", "1", "2", "52", "6.2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.7", "95.1", "", "", "", "", "94.1"]} -{"pcdb_id": 17550, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "18Ri ErP", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 18.0, "final_year_of_manufacture": 2018, "raw": ["017550", "000035", "0", "2020/Sep/08 10:49", "Bosch Thermotechnology", "Worcester", "Greenstar", "18Ri ErP", "41-406-45", "2015", "2018", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18", "18", "", "", "88.1", "79.1", "", "57.7", "", "2", "", "", "102", "1", "2", "53", "6.2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "97.0", "", "", "", "", "95.3"]} -{"pcdb_id": 17551, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "24Ri ErP LPG", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 24.0, "final_year_of_manufacture": 2018, "raw": ["017551", "000035", "0", "2020/Sep/08 10:49", "Bosch Thermotechnology", "Worcester", "Greenstar", "24Ri ErP LPG", "41-406-48", "2015", "2018", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "24", "24", "", "", "88.2", "79.2", "", "57.8", "", "2", "0", "0", "102", "1", "2", "58", "6.2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.7", "94.3", "", "", "", "", "93.4"]} -{"pcdb_id": 17553, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "24Ri ErP", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 24.0, "final_year_of_manufacture": 2018, "raw": ["017553", "000035", "0", "2020/Sep/08 10:49", "Bosch Thermotechnology", "Worcester", "Greenstar", "24Ri ErP", "41-406-47", "2015", "2018", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24", "24", "", "", "88.5", "79.5", "", "58.0", "", "2", "", "", "102", "1", "2", "54", "6.2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "97.9", "", "", "", "", "96.1"]} -{"pcdb_id": 17554, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "29CDi Classic ErP LPG", "winter_efficiency_pct": 89.5, "summer_efficiency_pct": 80.9, "comparative_hot_water_efficiency_pct": 56.9, "output_kw_max": 30.0, "final_year_of_manufacture": 2019, "raw": ["017554", "000035", "0", "2020/Jul/22 15:05", "Bosch Thermotechnology", "Worcester", "Greenstar", "29CDi Classic ErP LPG", "47-406-66", "2015", "2019", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "30.0", "30.0", "", "", "89.5", "80.9", "", "56.9", "", "2", "1", "", "104", "1", "2", "58", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "8305", "", "", "", "", "", "", "", "", "90.0", "100.2", "", "", "", "", "98.3"]} -{"pcdb_id": 17556, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "29CDi Classic ErP", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 86.7, "comparative_hot_water_efficiency_pct": 71.2, "output_kw_max": 30.0, "final_year_of_manufacture": 2019, "raw": ["017556", "000035", "0", "2020/Jul/22 15:07", "Bosch Thermotechnology", "Worcester", "Greenstar", "29CDi Classic ErP", "47-406-65", "2015", "2019", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "30.0", "30.0", "", "", "88.5", "86.7", "", "71.2", "", "2", "", "", "104", "1", "2", "58", "2", "0", "", "", "", "0", "", "", "", "", "1", "7.4", "0.122", "0.0061", "1.23987", "", "", "", "", "", "", "", "", "8305", "", "", "", "", "", "", "", "", "88.0", "98.0", "", "", "", "", "96.1"]} -{"pcdb_id": 17557, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "34CDi Classic ErP LPG", "winter_efficiency_pct": 89.5, "summer_efficiency_pct": 80.9, "comparative_hot_water_efficiency_pct": 56.9, "output_kw_max": 30.0, "final_year_of_manufacture": 2019, "raw": ["017557", "000035", "0", "2020/Jul/22 15:10", "Bosch Thermotechnology", "Worcester", "Greenstar", "34CDi Classic ErP LPG", "47-406-68", "2015", "2019", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "30.0", "30.0", "", "", "89.5", "80.9", "", "56.9", "", "2", "1", "", "104", "1", "2", "58", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "8305", "", "", "", "", "", "", "", "", "90.0", "100.2", "", "", "", "", "98.3"]} -{"pcdb_id": 17558, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "34CDi Classic ErP", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 86.7, "comparative_hot_water_efficiency_pct": 72.3, "output_kw_max": 30.0, "final_year_of_manufacture": 2019, "raw": ["017558", "000035", "0", "2020/Jul/22 15:15", "Bosch Thermotechnology", "Worcester", "Greenstar", "34CDi Classic ErP", "47-406-67", "2015", "2019", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "30.0", "30.0", "", "", "88.5", "86.7", "", "72.3", "", "2", "", "", "104", "1", "2", "58", "2", "0", "", "", "", "0", "", "", "", "", "1", "7.28", "0.123", "0.0039", "1.13727", "", "", "", "", "", "", "", "", "8305", "", "", "", "", "", "", "", "", "88.0", "98.0", "", "", "", "", "96.1"]} -{"pcdb_id": 17559, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "38CDi Classic ErP LPG", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 56.8, "output_kw_max": 30.0, "final_year_of_manufacture": 2019, "raw": ["017559", "000035", "0", "2020/Sep/08 13:44", "Bosch Thermotechnology", "Worcester", "Greenstar", "38CDi Classic ErP LPG", "47-406-70", "2015", "2019", "2", "2", "1", "2", "0", "", "", "2", "2", "1", "30.0", "30.0", "", "", "89.4", "80.8", "", "56.8", "", "2", "1", "", "104", "1", "2", "52", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "8305", "", "", "", "", "", "", "", "", "90.1", "99.9", "", "", "", "", "98.1"]} -{"pcdb_id": 17560, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "38CDi Classic ErP", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 86.7, "comparative_hot_water_efficiency_pct": 71.5, "output_kw_max": 30.0, "final_year_of_manufacture": 2019, "raw": ["017560", "000035", "0", "2020/Sep/08 13:45", "Bosch Thermotechnology", "Worcester", "Greenstar", "38CDi Classic ErP", "47-406-69", "2015", "2019", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "30.0", "30.0", "", "", "88.4", "86.7", "", "71.5", "", "2", "", "", "104", "1", "2", "52", "2", "0", "", "", "", "0", "", "", "", "", "1", "7.37", "0.129", "0.0039", "1.22598", "", "", "", "", "", "", "", "", "8305", "", "", "", "", "", "", "", "", "88.1", "97.8", "", "", "", "", "95.9"]} -{"pcdb_id": 17561, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "42CDi Classic ErP LPG", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 56.8, "output_kw_max": 30.0, "final_year_of_manufacture": 2019, "raw": ["017561", "000035", "0", "2020/Sep/08 13:45", "Bosch Thermotechnology", "Worcester", "Greenstar", "42CDi Classic ErP LPG", "47-406-72", "2015", "2019", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "30.0", "30.0", "", "", "89.4", "80.8", "", "56.8", "", "2", "1", "", "104", "1", "2", "51", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "8305", "", "", "", "", "", "", "", "", "90.1", "99.9", "", "", "", "", "98.1"]} -{"pcdb_id": 17562, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "42CDi Classic ErP", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 86.7, "comparative_hot_water_efficiency_pct": 72.0, "output_kw_max": 30.0, "final_year_of_manufacture": 2019, "raw": ["017562", "000035", "0", "2020/Sep/08 13:45", "Bosch Thermotechnology", "Worcester", "Greenstar", "42CDi Classic ErP", "47-406-71", "2015", "2019", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "30.0", "30.0", "", "", "88.4", "86.7", "", "72.0", "", "2", "", "", "104", "1", "2", "51", "2", "0", "", "", "", "0", "", "", "", "", "1", "7.31", "0.128", "0.0049", "1.16268", "", "", "", "", "", "", "", "", "8305", "", "", "", "", "", "", "", "", "88.1", "97.8", "", "", "", "", "95.9"]} -{"pcdb_id": 17563, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "30CDi Classic Regular ErP LPG", "winter_efficiency_pct": 89.5, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 58.8, "output_kw_max": 30.0, "final_year_of_manufacture": 2019, "raw": ["017563", "000035", "0", "2020/Sep/08 13:45", "Bosch Thermotechnology", "Worcester", "Greenstar", "30CDi Classic Regular ErP LPG", "41-406-34", "2015", "2019", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "30.0", "30.0", "", "", "89.5", "80.5", "", "58.8", "", "2", "1", "", "102", "1", "2", "58", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.0", "100.2", "", "", "", "", "98.3"]} -{"pcdb_id": 17564, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "30CDi Classic Regular ErP", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 30.0, "final_year_of_manufacture": 2019, "raw": ["017564", "000035", "0", "2020/Sep/08 13:46", "Bosch Thermotechnology", "Worcester", "Greenstar", "30CDi Classic Regular ErP", "41-406-33", "2015", "2019", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "30.0", "30.0", "", "", "88.5", "79.5", "", "58.1", "", "2", "", "", "102", "1", "2", "58", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "98.0", "", "", "", "", "96.1"]} -{"pcdb_id": 17565, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "40CDi Classic Regular ErP LPG", "winter_efficiency_pct": 89.5, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 58.8, "output_kw_max": 40.8, "final_year_of_manufacture": 2019, "raw": ["017565", "000035", "0", "2020/Sep/08 13:46", "Bosch Thermotechnology", "Worcester", "Greenstar", "40CDi Classic Regular ErP LPG", "41-406-36", "2015", "2019", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "40.8", "40.8", "", "", "89.5", "80.5", "", "58.8", "", "2", "1", "", "102", "1", "2", "90", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.8", "100.3", "", "", "", "", "98.3"]} -{"pcdb_id": 17566, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "40CDi Classic Regular ErP", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 40.8, "final_year_of_manufacture": 2019, "raw": ["017566", "000035", "0", "2020/Sep/08 13:46", "Bosch Thermotechnology", "Worcester", "Greenstar", "40CDi Classic Regular ErP", "41-406-35", "2015", "2019", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "40.8", "40.8", "", "", "88.5", "79.5", "", "58.1", "", "2", "", "", "102", "1", "2", "90", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "98.1", "", "", "", "", "96.2"]} -{"pcdb_id": 17567, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "30CDi Classic System ErP LPG", "winter_efficiency_pct": 89.5, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 58.8, "output_kw_max": 30.0, "final_year_of_manufacture": 2019, "raw": ["017567", "000035", "0", "2020/Sep/08 13:46", "Bosch Thermotechnology", "Worcester", "Greenstar", "30CDi Classic System ErP LPG", "41-406-38", "2015", "2019", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "30.0", "30.0", "", "", "89.5", "80.5", "", "58.8", "", "2", "1", "", "102", "1", "2", "58", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "8305", "", "", "", "", "", "", "", "", "90.0", "100.2", "", "", "", "", "98.3"]} -{"pcdb_id": 17568, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "30CDi Classic System ErP", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 30.0, "final_year_of_manufacture": 2019, "raw": ["017568", "000035", "0", "2020/Sep/08 13:46", "Bosch Thermotechnology", "Worcester", "Greenstar", "30CDi Classic System ErP", "41-406-37", "2015", "2019", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "30.0", "30.0", "", "", "88.5", "79.5", "", "58.1", "", "2", "", "", "102", "1", "2", "58", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "8305", "", "", "", "", "", "", "", "", "88.0", "98.0", "", "", "", "", "96.1"]} -{"pcdb_id": 17569, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "35CDi Classic System ErP LPG", "winter_efficiency_pct": 89.5, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 58.8, "output_kw_max": 34.0, "final_year_of_manufacture": 2019, "raw": ["017569", "000035", "0", "2020/Sep/08 13:46", "Bosch Thermotechnology", "Worcester", "Greenstar", "35CDi Classic System ErP LPG", "41-406-40", "2015", "2019", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "34.0", "34.0", "", "", "89.5", "80.5", "", "58.8", "", "2", "1", "", "102", "1", "2", "60", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "8305", "", "", "", "", "", "", "", "", "89.8", "100.3", "", "", "", "", "98.3"]} -{"pcdb_id": 17570, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "35CDi Classic System ErP", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 34.0, "final_year_of_manufacture": 2019, "raw": ["017570", "000035", "0", "2020/Sep/08 13:46", "Bosch Thermotechnology", "Worcester", "Greenstar", "35CDi Classic System ErP", "41-406-39", "2015", "2019", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "34.0", "34.0", "", "", "88.5", "79.5", "", "58.1", "", "2", "", "", "102", "1", "2", "60", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "8305", "", "", "", "", "", "", "", "", "87.8", "98.1", "", "", "", "", "96.2"]} -{"pcdb_id": 17572, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "FS 30CDi Regular ErP", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 30.0, "final_year_of_manufacture": null, "raw": ["017572", "000035", "0", "2015/Apr/27 15:10", "Bosch Thermotechnology", "Worcester", "Greenstar", "FS 30CDi Regular ErP", "41-406-03", "2008", "current", "1", "1", "1", "1", "0", "", "", "2", "2", "2", "30", "30", "", "", "88.2", "79.2", "", "57.9", "", "2", "", "", "102", "1", "2", "60", "9", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.6", "97.1", "", "", "", "", "95.5"]} -{"pcdb_id": 17574, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "FS 42CDi Regular ErP", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 40.8, "final_year_of_manufacture": null, "raw": ["017574", "000035", "0", "2015/Apr/27 15:09", "Bosch Thermotechnology", "Worcester", "Greenstar", "FS 42CDi Regular ErP", "41-406-04", "2008", "current", "1", "1", "1", "1", "0", "", "", "2", "2", "2", "40.8", "40.8", "", "", "88.1", "79.1", "", "57.8", "", "2", "", "", "102", "1", "2", "80", "9", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.1", "97.0", "", "", "", "", "95.3"]} -{"pcdb_id": 17576, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "Highflow 440CDi ErP", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 80.9, "comparative_hot_water_efficiency_pct": 43.8, "output_kw_max": 29.2, "final_year_of_manufacture": null, "raw": ["017576", "000035", "0", "2024/Jan/31 10:17", "Bosch Thermotechnology", "Worcester", "Greenstar", "Highflow 440CDi ErP", "47-406-85", "2008", "current", "1", "1", "1", "2", "0", "", "", "2", "2", "2", "29.2", "29.2", "", "", "88.2", "80.9", "", "43.8", "", "2", "", "", "106", "1", "2", "164", "10", "1", "1", "", "47", "0", "25", "3", "65", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "8305", "", "", "", "", "", "", "", "", "88.6", "97.1", "", "", "", "", "95.5"]} -{"pcdb_id": 17578, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "Highflow 550CDi ErP", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 80.9, "comparative_hot_water_efficiency_pct": 43.8, "output_kw_max": 30.6, "final_year_of_manufacture": null, "raw": ["017578", "000035", "0", "2024/Jan/31 10:17", "Bosch Thermotechnology", "Worcester", "Greenstar", "Highflow 550CDi ErP", "47-406-87", "2008", "current", "1", "1", "1", "2", "0", "", "", "2", "2", "2", "30.6", "30.6", "", "", "88.2", "80.9", "", "43.8", "", "2", "", "", "106", "1", "2", "164", "10", "1", "1", "", "47", "0", "25", "3", "65", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "8305", "", "", "", "", "", "", "", "", "88.6", "97.1", "", "", "", "", "95.5"]} -{"pcdb_id": 17580, "brand_name": "ATAG", "model_name": "iR15", "model_qualifier": "", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 13.3, "final_year_of_manufacture": null, "raw": ["017580", "000299", "0", "2015/Jun/08 16:04", "ATAG Verwarming Nederland BV", "ATAG", "iR15", "", "41-310-32", "2015", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "13.3", "13.3", "", "", "89.1", "80.1", "", "58.5", "", "2", "", "", "102", "1", "2", "23", "4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.8", "99.2", "", "", "", "", "97.2"]} -{"pcdb_id": 17581, "brand_name": "ATAG", "model_name": "iS32", "model_qualifier": "", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 18.0, "final_year_of_manufacture": null, "raw": ["017581", "000299", "0", "2015/Jun/08 16:05", "ATAG Verwarming Nederland BV", "ATAG", "iS32", "", "41-310-26", "2015", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "18", "18", "", "", "89.1", "80.1", "", "58.5", "", "2", "", "", "102", "1", "2", "74", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.6", "99.5", "", "", "", "", "97.4"]} -{"pcdb_id": 17582, "brand_name": "ATAG", "model_name": "iS15", "model_qualifier": "", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 13.3, "final_year_of_manufacture": null, "raw": ["017582", "000299", "0", "2015/Jun/08 16:10", "ATAG Verwarming Nederland BV", "ATAG", "iS15", "", "41-310-20", "2015", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "13.3", "13.3", "", "", "89.1", "80.1", "", "58.5", "", "2", "", "", "102", "1", "2", "68", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.8", "99.2", "", "", "", "", "97.2"]} -{"pcdb_id": 17583, "brand_name": "ATAG", "model_name": "iS24", "model_qualifier": "", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 21.2, "final_year_of_manufacture": null, "raw": ["017583", "000299", "0", "2015/Jun/08 16:10", "ATAG Verwarming Nederland BV", "ATAG", "iS24", "", "41-310-24", "2015", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "21.2", "21.2", "", "", "89.1", "80.1", "", "58.5", "", "2", "", "", "102", "1", "2", "96", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "99.4", "", "", "", "", "97.3"]} -{"pcdb_id": 17585, "brand_name": "ATAG", "model_name": "iR32", "model_qualifier": "", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 28.4, "final_year_of_manufacture": null, "raw": ["017585", "000299", "0", "2015/Jun/08 16:11", "ATAG Verwarming Nederland BV", "ATAG", "iR32", "", "41-310-38", "2015", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "28.4", "28.4", "", "", "89.1", "80.1", "", "58.5", "", "2", "", "", "102", "1", "2", "40", "4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.6", "99.5", "", "", "", "", "97.4"]} -{"pcdb_id": 17586, "brand_name": "ATAG", "model_name": "iR24", "model_qualifier": "", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 21.2, "final_year_of_manufacture": null, "raw": ["017586", "000299", "0", "2015/Jun/08 16:12", "ATAG Verwarming Nederland BV", "ATAG", "iR24", "", "41-310-36", "2015", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "21.2", "21.2", "", "", "89.1", "80.1", "", "58.5", "", "2", "", "", "102", "1", "2", "36", "4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "99.4", "", "", "", "", "97.3"]} -{"pcdb_id": 17587, "brand_name": "ATAG", "model_name": "iC40", "model_qualifier": "", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 88.2, "comparative_hot_water_efficiency_pct": 76.5, "output_kw_max": 28.3, "final_year_of_manufacture": null, "raw": ["017587", "000299", "0", "2020/Apr/09 16:13", "ATAG Verwarming Nederland BV", "ATAG", "iC40", "", "47-310-25", "2015", "current", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "28.3", "28.3", "", "", "89.1", "88.2", "", "76.5", "", "2", "", "", "104", "1", "2", "74", "5", "0", "", "", "", "0", "", "", "", "", "2", "6.885", "0.179", "0.0008", "0.78828", "12.646", "0.196", "0.0004", "0.75508", "0.0", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.6", "99.5", "", "", "", "", "97.4"]} -{"pcdb_id": 17588, "brand_name": "ATAG", "model_name": "iR18", "model_qualifier": "", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 15.9, "final_year_of_manufacture": null, "raw": ["017588", "000299", "0", "2015/Jun/08 16:19", "ATAG Verwarming Nederland BV", "ATAG", "iR18", "", "41-310-34", "2015", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "15.9", "15.9", "", "", "89.1", "80.1", "", "58.5", "", "2", "", "", "102", "1", "2", "28", "4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.6", "99.4", "", "", "", "", "97.3"]} -{"pcdb_id": 17589, "brand_name": "ATAG", "model_name": "iC36", "model_qualifier": "", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 86.9, "comparative_hot_water_efficiency_pct": 76.6, "output_kw_max": 28.3, "final_year_of_manufacture": null, "raw": ["017589", "000299", "0", "2020/Jan/22 13:14", "ATAG Verwarming Nederland BV", "ATAG", "iC36", "", "47-310-23", "2015", "current", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "28.3", "28.3", "", "", "89.1", "86.9", "", "76.6", "", "2", "", "", "104", "1", "2", "74", "5", "0", "", "", "", "0", "", "", "", "", "1", "6.872", "0.182", "0.0008", "0.77574", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.6", "99.5", "", "", "", "", "97.4"]} -{"pcdb_id": 17590, "brand_name": "ATAG", "model_name": "iC28", "model_qualifier": "", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 88.2, "comparative_hot_water_efficiency_pct": 77.4, "output_kw_max": 21.2, "final_year_of_manufacture": null, "raw": ["017590", "000299", "0", "2020/Apr/09 16:13", "ATAG Verwarming Nederland BV", "ATAG", "iC28", "", "47-310-21", "2015", "current", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "21.2", "21.2", "", "", "89.1", "88.2", "", "77.4", "", "2", "", "", "104", "1", "2", "74", "5", "0", "", "", "", "0", "", "", "", "", "2", "6.802", "0.169", "0.0008", "0.70169", "12.464", "0.178", "0.0004", "0.67557", "0.0", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "99.4", "", "", "", "", "97.3"]} -{"pcdb_id": 17591, "brand_name": "ATAG", "model_name": "iC24", "model_qualifier": "", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 88.2, "comparative_hot_water_efficiency_pct": 77.4, "output_kw_max": 21.2, "final_year_of_manufacture": null, "raw": ["017591", "000299", "0", "2020/Apr/09 16:12", "ATAG Verwarming Nederland BV", "ATAG", "iC24", "", "47-310-19", "2015", "current", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "21.2", "21.2", "", "", "89.1", "88.2", "", "77.4", "", "2", "", "", "104", "1", "2", "74", "5", "0", "", "", "", "0", "", "", "", "", "2", "6.806", "0.168", "0.0008", "0.70552", "12.475", "0.188", "0.0004", "0.67938", "0.0", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "99.4", "", "", "", "", "97.3"]} -{"pcdb_id": 17592, "brand_name": "ATAG", "model_name": "iS40", "model_qualifier": "", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 35.4, "final_year_of_manufacture": null, "raw": ["017592", "000299", "0", "2015/Jun/08 16:21", "ATAG Verwarming Nederland BV", "ATAG", "iS40", "", "41-310-28", "2015", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "35.4", "35.4", "", "", "89.1", "80.1", "", "58.5", "", "2", "", "", "102", "1", "2", "99", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.4", "99.4", "", "", "", "", "97.3"]} -{"pcdb_id": 17593, "brand_name": "ATAG", "model_name": "iR40", "model_qualifier": "", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 35.4, "final_year_of_manufacture": null, "raw": ["017593", "000299", "0", "2015/Jun/08 16:22", "ATAG Verwarming Nederland BV", "ATAG", "iR40", "", "41-310-40", "2015", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "35.4", "35.4", "", "", "89.1", "80.1", "", "58.5", "", "2", "", "", "102", "1", "2", "46", "4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.4", "99.4", "", "", "", "", "97.3"]} -{"pcdb_id": 17594, "brand_name": "ATAG", "model_name": "iS18", "model_qualifier": "", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 15.9, "final_year_of_manufacture": null, "raw": ["017594", "000299", "0", "2015/Jun/08 16:22", "ATAG Verwarming Nederland BV", "ATAG", "iS18", "", "41-310-22", "2015", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "15.9", "15.9", "", "", "89.1", "80.1", "", "58.5", "", "2", "", "", "102", "1", "2", "77", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.6", "99.4", "", "", "", "", "97.3"]} -{"pcdb_id": 17595, "brand_name": "Alpha", "model_name": "InTec2 35CE", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 86.7, "comparative_hot_water_efficiency_pct": 72.1, "output_kw_max": 28.0, "final_year_of_manufacture": null, "raw": ["017595", "000001", "0", "2016/Sep/20 00:00", "Alpha Therm", "Alpha", "InTec2 35CE", "", "", "2015", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28", "28", "", "", "88.3", "86.7", "", "72.1", "", "2", "", "", "104", "1", "2", "105", "6", "0", "", "", "", "0", "", "", "", "", "1", "7.303", "0.104", "0.0112", "1.11644", "", "", "", "", "", "", "", "", "1005", "", "", "", "", "", "", "", "", "88.0", "97.6", "", "", "", "", "95.8"]} -{"pcdb_id": 17596, "brand_name": "Alpha", "model_name": "InTec2 30CE", "model_qualifier": "", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 86.6, "comparative_hot_water_efficiency_pct": 75.0, "output_kw_max": 24.0, "final_year_of_manufacture": null, "raw": ["017596", "000001", "0", "2016/Sep/20 00:00", "Alpha Therm", "Alpha", "InTec2 30CE", "", "", "2015", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "88.2", "86.6", "", "75.0", "", "2", "", "", "104", "1", "2", "95", "6", "0", "", "", "", "0", "", "", "", "", "1", "7.019", "0.125", "0.0045", "0.87804", "", "", "", "", "", "", "", "", "1005", "", "", "", "", "", "", "", "", "87.8", "97.4", "", "", "", "", "95.6"]} -{"pcdb_id": 17597, "brand_name": "Alpha", "model_name": "InTec2 30SE", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 28.0, "final_year_of_manufacture": null, "raw": ["017597", "000001", "0", "2016/Sep/20 00:00", "Alpha Therm", "Alpha", "InTec2 30SE", "", "", "2015", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "28", "28", "", "", "88.3", "79.3", "", "57.9", "", "2", "", "", "102", "1", "2", "105", "6", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "1005", "", "", "", "", "", "", "", "", "88.0", "97.6", "", "", "", "", "95.8"]} -{"pcdb_id": 17598, "brand_name": "Alpha", "model_name": "InTec2 26CE", "model_qualifier": "", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 86.6, "comparative_hot_water_efficiency_pct": 73.7, "output_kw_max": 20.0, "final_year_of_manufacture": null, "raw": ["017598", "000001", "0", "2016/Sep/20 00:00", "Alpha Therm", "Alpha", "InTec2 26CE", "", "", "2015", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "20", "20", "", "", "88.2", "86.6", "", "73.7", "", "2", "", "", "104", "1", "2", "90", "6", "0", "", "", "", "0", "", "", "", "", "1", "7.144", "0.117", "0.0122", "0.95089", "", "", "", "", "", "", "", "", "1005", "", "", "", "", "", "", "", "", "87.8", "97.4", "", "", "", "", "95.6"]} -{"pcdb_id": 17599, "brand_name": "Alpha", "model_name": "InTec2 20SE", "model_qualifier": "", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 18.0, "final_year_of_manufacture": null, "raw": ["017599", "000001", "0", "2016/Sep/20 00:00", "Alpha Therm", "Alpha", "InTec2 20SE", "", "", "2015", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18", "18", "", "", "88.2", "79.2", "", "57.9", "", "2", "", "", "102", "1", "2", "85", "6", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "1005", "", "", "", "", "", "", "", "", "87.8", "97.4", "", "", "", "", "95.6"]} -{"pcdb_id": 17600, "brand_name": "Alpha", "model_name": "InTec2 20SE", "model_qualifier": "", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 18.0, "final_year_of_manufacture": null, "raw": ["017600", "000001", "0", "2016/Sep/20 00:00", "Alpha Therm", "Alpha", "InTec2 20SE", "", "", "2015", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "18", "18", "", "", "89.2", "80.2", "", "58.6", "", "2", "1", "", "102", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "1005", "", "", "", "", "", "", "", "", "89.7", "99.6", "", "", "", "", "97.7"]} -{"pcdb_id": 17601, "brand_name": "Alpha", "model_name": "InTec2 26CE", "model_qualifier": "", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 88.5, "comparative_hot_water_efficiency_pct": 74.9, "output_kw_max": 20.0, "final_year_of_manufacture": null, "raw": ["017601", "000001", "0", "2016/Sep/20 00:00", "Alpha Therm", "Alpha", "InTec2 26CE", "", "", "2015", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "20", "20", "", "", "89.2", "88.5", "", "74.9", "", "2", "1", "", "104", "1", "2", "90", "6", "0", "", "", "", "0", "", "", "", "", "1", "7.188", "0.126", "0.0079", "1.0182", "", "", "", "", "", "", "", "", "1005", "", "", "", "", "", "", "", "", "89.7", "99.6", "", "", "", "", "97.7"]} -{"pcdb_id": 17602, "brand_name": "Alpha", "model_name": "InTec2 30CE", "model_qualifier": "", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 88.6, "comparative_hot_water_efficiency_pct": 74.5, "output_kw_max": 24.0, "final_year_of_manufacture": null, "raw": ["017602", "000001", "0", "2016/Sep/20 00:00", "Alpha Therm", "Alpha", "InTec2 30CE", "", "", "2015", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "89.2", "88.6", "", "74.5", "", "2", "1", "", "104", "1", "2", "105", "6", "0", "", "", "", "0", "", "", "", "", "1", "7.229", "0.122", "0.0086", "1.05571", "", "", "", "", "", "", "", "", "1005", "", "", "", "", "", "", "", "", "89.8", "99.6", "", "", "", "", "97.7"]} -{"pcdb_id": 17603, "brand_name": "Alpha", "model_name": "InTec2 30SE", "model_qualifier": "", "winter_efficiency_pct": 89.3, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 58.7, "output_kw_max": 28.0, "final_year_of_manufacture": null, "raw": ["017603", "000001", "0", "2016/Sep/20 00:00", "Alpha Therm", "Alpha", "InTec2 30SE", "", "", "2015", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "28", "28", "", "", "89.3", "80.3", "", "58.7", "", "2", "1", "", "102", "1", "2", "105", "6", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "1005", "", "", "", "", "", "", "", "", "90.0", "99.7", "", "", "", "", "97.9"]} -{"pcdb_id": 17604, "brand_name": "Alpha", "model_name": "InTec2 35CE", "model_qualifier": "", "winter_efficiency_pct": 89.3, "summer_efficiency_pct": 88.6, "comparative_hot_water_efficiency_pct": 72.6, "output_kw_max": 28.0, "final_year_of_manufacture": null, "raw": ["017604", "000001", "0", "2016/Sep/20 00:00", "Alpha Therm", "Alpha", "InTec2 35CE", "", "", "2015", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "28", "28", "", "", "89.3", "88.6", "", "72.6", "", "2", "1", "", "104", "1", "2", "", "", "0", "", "", "", "0", "", "", "", "", "1", "7.416", "0.104", "0.0085", "1.24124", "", "", "", "", "", "", "", "", "1005", "", "", "", "", "", "", "", "", "90.0", "99.7", "", "", "", "", "97.9"]} -{"pcdb_id": 17606, "brand_name": "Alpha", "model_name": "Eco2 Plus", "model_qualifier": "", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 86.6, "comparative_hot_water_efficiency_pct": 72.8, "output_kw_max": 24.0, "final_year_of_manufacture": null, "raw": ["017606", "000001", "0", "2016/Sep/20 00:00", "Alpha Therm", "Alpha", "Eco2 Plus", "", "", "2015", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.0", "24.0", "", "", "88.2", "86.6", "", "72.8", "", "2", "", "", "104", "1", "2", "95", "4.5", "0", "", "", "", "0", "", "", "", "", "1", "7.23", "0.121", "0.0159", "1.01136", "", "", "", "", "", "", "", "", "1005", "", "", "", "", "", "", "", "", "87.8", "97.4", "", "", "", "", "95.6"]} -{"pcdb_id": 17609, "brand_name": "Alpha", "model_name": "Eco2 Plus", "model_qualifier": "", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 88.5, "comparative_hot_water_efficiency_pct": 73.2, "output_kw_max": 24.0, "final_year_of_manufacture": null, "raw": ["017609", "000001", "0", "2016/Sep/20 00:00", "Alpha Therm", "Alpha", "Eco2 Plus", "", "", "2015", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24.0", "24.0", "", "", "89.2", "88.5", "", "73.2", "", "2", "1", "", "104", "1", "2", "95", "4.5", "0", "", "", "", "0", "", "", "", "", "1", "7.353", "0.123", "0.0081", "1.17575", "", "", "", "", "", "", "", "", "1005", "", "", "", "", "", "", "", "", "89.7", "99.6", "", "", "", "", "97.7"]} -{"pcdb_id": 17610, "brand_name": "Alpha", "model_name": "InTec2 25XE", "model_qualifier": "", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 86.6, "comparative_hot_water_efficiency_pct": 73.1, "output_kw_max": 20.0, "final_year_of_manufacture": null, "raw": ["017610", "000001", "0", "2016/Sep/20 00:00", "Alpha Therm", "Alpha", "InTec2 25XE", "", "", "2015", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "20.0", "20.0", "", "", "88.2", "86.6", "", "73.1", "", "2", "", "", "104", "1", "2", "90", "4.5", "0", "", "", "", "0", "", "", "", "", "1", "7.209", "0.126", "0.0171", "0.98444", "", "", "", "", "", "", "", "", "1005", "", "", "", "", "", "", "", "", "87.8", "97.3", "", "", "", "", "95.5"]} -{"pcdb_id": 17611, "brand_name": "Alpha", "model_name": "InTec2 25XE", "model_qualifier": "", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 88.5, "comparative_hot_water_efficiency_pct": 75.2, "output_kw_max": 20.0, "final_year_of_manufacture": null, "raw": ["017611", "000001", "0", "2016/Sep/20 00:00", "Alpha Therm", "Alpha", "InTec2 25XE", "", "", "2015", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "20.0", "20.0", "", "", "89.2", "88.5", "", "75.2", "", "2", "1", "", "104", "1", "2", "90", "4.5", "0", "", "", "", "0", "", "", "", "", "1", "7.157", "0.119", "0.0088", "0.98297", "", "", "", "", "", "", "", "", "1005", "", "", "", "", "", "", "", "", "89.7", "99.5", "", "", "", "", "97.6"]} -{"pcdb_id": 17612, "brand_name": "Alpha", "model_name": "InTec2 28XE", "model_qualifier": "", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 86.6, "comparative_hot_water_efficiency_pct": 72.8, "output_kw_max": 24.0, "final_year_of_manufacture": null, "raw": ["017612", "000001", "0", "2016/Sep/20 00:00", "Alpha Therm", "Alpha", "InTec2 28XE", "", "", "2015", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.0", "24.0", "", "", "88.2", "86.6", "", "72.8", "", "2", "", "", "104", "1", "2", "95", "4.5", "0", "", "", "", "0", "", "", "", "", "1", "7.231", "0.121", "0.016", "1.0123", "", "", "", "", "", "", "", "", "1005", "", "", "", "", "", "", "", "", "87.8", "97.4", "", "", "", "", "95.6"]} -{"pcdb_id": 17613, "brand_name": "Alpha", "model_name": "InTec2 28XE", "model_qualifier": "", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 88.5, "comparative_hot_water_efficiency_pct": 73.2, "output_kw_max": 24.0, "final_year_of_manufacture": null, "raw": ["017613", "000001", "0", "2016/Sep/20 00:00", "Alpha Therm", "Alpha", "InTec2 28XE", "", "", "2015", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24.0", "24.0", "", "", "89.2", "88.5", "", "73.2", "", "2", "1", "", "104", "1", "2", "95", "4.5", "0", "", "", "", "0", "", "", "", "", "1", "7.353", "0.123", "0.0081", "1.17575", "", "", "", "", "", "", "", "", "1005", "", "", "", "", "", "", "", "", "89.7", "99.6", "", "", "", "", "97.7"]} -{"pcdb_id": 17614, "brand_name": "Potterton", "model_name": "Promax Ultra", "model_qualifier": "Combi 24 ErP", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 86.7, "comparative_hot_water_efficiency_pct": 77.6, "output_kw_max": 20.0, "final_year_of_manufacture": null, "raw": ["017614", "000005", "0", "2015/Sep/21 14:23", "Baxi Heating UK", "Potterton", "Promax Ultra", "Combi 24 ErP", "GC No. 47-393-54", "2015", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "20", "20", "", "", "88.5", "86.7", "", "77.6", "", "2", "", "", "104", "1", "2", "85", "3.5", "0", "", "", "", "0", "", "", "", "", "1", "6.786", "0.098", "0.0043", "0.65911", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "88.0", "98.0", "", "", "", "", "96.1"]} -{"pcdb_id": 17615, "brand_name": "Potterton", "model_name": "Promax Ultra", "model_qualifier": "Combi 28 ErP", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 86.7, "comparative_hot_water_efficiency_pct": 77.3, "output_kw_max": 24.0, "final_year_of_manufacture": null, "raw": ["017615", "000005", "0", "2016/Jul/13 14:38", "Baxi Heating UK", "Potterton", "Promax Ultra", "Combi 28 ErP", "GC No. 47-393-55", "2015", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "88.5", "86.7", "", "77.3", "", "2", "", "", "104", "1", "2", "90", "3.5", "0", "", "", "", "0", "", "", "", "", "1", "6.813", "0.098", "0.0044", "0.68225", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "87.9", "98.0", "", "", "", "", "96.1"]} -{"pcdb_id": 17616, "brand_name": "Potterton", "model_name": "Promax Ultra", "model_qualifier": "Combi 33 ErP", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 86.7, "comparative_hot_water_efficiency_pct": 77.3, "output_kw_max": 28.0, "final_year_of_manufacture": null, "raw": ["017616", "000005", "0", "2015/Sep/21 14:23", "Baxi Heating UK", "Potterton", "Promax Ultra", "Combi 33 ErP", "GC No. 47-393-56", "2015", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28", "28", "", "", "88.5", "86.7", "", "77.3", "", "2", "", "", "104", "1", "2", "95", "3.5", "0", "", "", "", "0", "", "", "", "", "1", "6.812", "0.086", "0.0045", "0.68548", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "88.1", "98.1", "", "", "", "", "96.2"]} -{"pcdb_id": 17617, "brand_name": "Potterton", "model_name": "Promax Ultra", "model_qualifier": "Combi 40 ErP", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 86.7, "comparative_hot_water_efficiency_pct": 77.6, "output_kw_max": 32.0, "final_year_of_manufacture": null, "raw": ["017617", "000005", "0", "2015/Sep/21 14:23", "Baxi Heating UK", "Potterton", "Promax Ultra", "Combi 40 ErP", "GC No. 47-393-57", "2015", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "32", "32", "", "", "88.5", "86.7", "", "77.6", "", "2", "", "", "104", "1", "2", "100", "3.5", "0", "", "", "", "0", "", "", "", "", "1", "6.786", "0.098", "0.0043", "0.65689", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "87.9", "98.0", "", "", "", "", "96.1"]} -{"pcdb_id": 17619, "brand_name": "Grant", "model_name": "Vortex Eco", "model_qualifier": "Utility System 15-21", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 21.5, "final_year_of_manufacture": null, "raw": ["017619", "000048", "0", "2015/Jul/16 14:45", "Grant Engineering (UK)", "Grant", "Vortex Eco", "Utility System 15-21", "", "2015", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "15.5", "21.5", "", "", "88.0", "80.2", "", "58.6", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.5", "94.4", "", "", "", "", "93.9"]} -{"pcdb_id": 17623, "brand_name": "Grant", "model_name": "Vortex Eco", "model_qualifier": "Utility System 21-26", "winter_efficiency_pct": 87.8, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 26.3, "final_year_of_manufacture": null, "raw": ["017623", "000048", "0", "2015/Jul/16 14:46", "Grant Engineering (UK)", "Grant", "Vortex Eco", "Utility System 21-26", "", "2015", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "21.5", "26.3", "", "", "87.8", "80.0", "", "58.4", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.4", "94.4", "", "", "", "", "93.6"]} -{"pcdb_id": 17624, "brand_name": "Grant", "model_name": "Vortex Eco", "model_qualifier": "Utility System 26-35", "winter_efficiency_pct": 87.5, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 35.3, "final_year_of_manufacture": null, "raw": ["017624", "000048", "0", "2015/Jul/16 14:47", "Grant Engineering (UK)", "Grant", "Vortex Eco", "Utility System 26-35", "", "2015", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "26.3", "35.3", "", "", "87.5", "79.7", "", "58.2", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.3", "93.8", "", "", "", "", "93.1"]} -{"pcdb_id": 17625, "brand_name": "Grant", "model_name": "Vortex Eco", "model_qualifier": "External System 15-21", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 21.5, "final_year_of_manufacture": null, "raw": ["017625", "000048", "0", "2015/Jul/16 14:48", "Grant Engineering (UK)", "Grant", "Vortex Eco", "External System 15-21", "", "2015", "current", "4", "1", "2", "1", "0", "", "", "2", "3", "2", "15.5", "21.5", "", "", "88.0", "80.2", "", "58.6", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.5", "94.4", "", "", "", "", "93.9"]} -{"pcdb_id": 17626, "brand_name": "Grant", "model_name": "Vortex Eco", "model_qualifier": "External System 21-26", "winter_efficiency_pct": 87.8, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 26.3, "final_year_of_manufacture": null, "raw": ["017626", "000048", "0", "2015/Jul/16 14:49", "Grant Engineering (UK)", "Grant", "Vortex Eco", "External System 21-26", "", "2015", "current", "4", "1", "2", "1", "0", "", "", "2", "3", "1", "21.5", "26.3", "", "", "87.8", "80.0", "", "58.4", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.4", "94.4", "", "", "", "", "93.6"]} -{"pcdb_id": 17627, "brand_name": "Grant", "model_name": "Vortex Eco", "model_qualifier": "External System 26-35", "winter_efficiency_pct": 87.5, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 35.3, "final_year_of_manufacture": null, "raw": ["017627", "000048", "0", "2015/Jul/16 14:49", "Grant Engineering (UK)", "Grant", "Vortex Eco", "External System 26-35", "", "2015", "current", "4", "1", "2", "1", "0", "", "", "2", "3", "2", "26.3", "35.3", "", "", "87.5", "79.7", "", "58.2", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.3", "93.8", "", "", "", "", "93.1"]} -{"pcdb_id": 17628, "brand_name": "Baxi", "model_name": "Ecoblue Advance 24 Combi ErPD", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 86.7, "comparative_hot_water_efficiency_pct": 77.6, "output_kw_max": 20.0, "final_year_of_manufacture": null, "raw": ["017628", "000005", "0", "2015/Sep/21 14:23", "Baxi Heating UK", "Baxi", "Ecoblue Advance 24 Combi ErPD", "", "GC No. 47-077-14", "2015", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "20", "20", "", "", "88.5", "86.7", "", "77.6", "", "2", "", "", "104", "1", "2", "85", "3.5", "0", "", "", "", "0", "", "", "", "", "1", "6.786", "0.098", "0.0043", "0.65911", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "88.0", "98.0", "", "", "", "", "96.1"]} -{"pcdb_id": 17629, "brand_name": "Baxi", "model_name": "Ecoblue Advance 28 Combi ErPD", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 86.7, "comparative_hot_water_efficiency_pct": 77.3, "output_kw_max": 24.0, "final_year_of_manufacture": null, "raw": ["017629", "000005", "0", "2015/Sep/21 14:23", "Baxi Heating UK", "Baxi", "Ecoblue Advance 28 Combi ErPD", "", "GC No. 47-077-15", "2015", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "88.5", "86.7", "", "77.3", "", "2", "", "", "104", "1", "2", "90", "3.5", "0", "", "", "", "0", "", "", "", "", "1", "6.813", "0.098", "0.0044", "0.68225", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "87.9", "98.0", "", "", "", "", "96.1"]} -{"pcdb_id": 17630, "brand_name": "Baxi", "model_name": "Ecoblue Advance 33 Combi ErPD", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 86.7, "comparative_hot_water_efficiency_pct": 77.2, "output_kw_max": 28.0, "final_year_of_manufacture": null, "raw": ["017630", "000005", "0", "2015/Sep/21 14:23", "Baxi Heating UK", "Baxi", "Ecoblue Advance 33 Combi ErPD", "", "GC No. 47-077-16", "2015", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28", "28", "", "", "88.5", "86.7", "", "77.2", "", "2", "", "", "104", "1", "2", "95", "3.5", "0", "", "", "", "0", "", "", "", "", "1", "6.821", "0.086", "0.0045", "0.69191", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "88.0", "98.1", "", "", "", "", "96.2"]} -{"pcdb_id": 17631, "brand_name": "Baxi", "model_name": "Ecoblue Advance 40 Combi ErPD", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 86.7, "comparative_hot_water_efficiency_pct": 77.6, "output_kw_max": 32.0, "final_year_of_manufacture": null, "raw": ["017631", "000005", "0", "2015/Sep/21 14:23", "Baxi Heating UK", "Baxi", "Ecoblue Advance 40 Combi ErPD", "", "GC No. 47-077-17", "2015", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "32", "32", "", "", "88.5", "86.7", "", "77.6", "", "2", "", "", "104", "1", "2", "100", "3.5", "0", "", "", "", "0", "", "", "", "", "1", "6.786", "0.098", "0.0043", "0.65689", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "87.9", "98.0", "", "", "", "", "96.1"]} -{"pcdb_id": 17632, "brand_name": "Baxi", "model_name": "Ecoblue 24 Combi ErP", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 86.7, "comparative_hot_water_efficiency_pct": 77.6, "output_kw_max": 20.0, "final_year_of_manufacture": null, "raw": ["017632", "000005", "0", "2015/Sep/21 14:23", "Baxi Heating UK", "Baxi", "Ecoblue 24 Combi ErP", "", "GC No. 47-077-11", "2015", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "20", "20", "", "", "88.5", "86.7", "", "77.6", "", "2", "", "", "104", "1", "2", "85", "3.5", "0", "", "", "", "0", "", "", "", "", "1", "6.786", "0.098", "0.0043", "0.65911", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "88.0", "98.0", "", "", "", "", "96.1"]} -{"pcdb_id": 17633, "brand_name": "Baxi", "model_name": "Ecoblue 28 Combi ErP", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 86.7, "comparative_hot_water_efficiency_pct": 77.3, "output_kw_max": 24.0, "final_year_of_manufacture": null, "raw": ["017633", "000005", "0", "2015/Sep/21 14:23", "Baxi Heating UK", "Baxi", "Ecoblue 28 Combi ErP", "", "GC No. 47-077-12", "2015", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "88.5", "86.7", "", "77.3", "", "2", "", "", "104", "1", "2", "90", "3.5", "0", "", "", "", "0", "", "", "", "", "1", "6.813", "0.098", "0.0044", "0.68225", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "87.9", "98.0", "", "", "", "", "96.1"]} -{"pcdb_id": 17634, "brand_name": "Baxi", "model_name": "Ecoblue33 Combi ErP", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 86.7, "comparative_hot_water_efficiency_pct": 77.2, "output_kw_max": 28.0, "final_year_of_manufacture": null, "raw": ["017634", "000005", "0", "2015/Sep/21 14:23", "Baxi Heating UK", "Baxi", "Ecoblue33 Combi ErP", "", "GC No. 47-077-13", "2014", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28", "28", "", "", "88.5", "86.7", "", "77.2", "", "2", "", "", "104", "1", "2", "95", "3.5", "0", "", "", "", "0", "", "", "", "", "1", "6.821", "0.086", "0.0045", "0.69191", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "88.0", "98.1", "", "", "", "", "96.2"]} -{"pcdb_id": 17635, "brand_name": "Baxi", "model_name": "Ecoblue + 24 Combi ErP", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 86.7, "comparative_hot_water_efficiency_pct": 77.6, "output_kw_max": 20.0, "final_year_of_manufacture": null, "raw": ["017635", "000005", "0", "2015/Sep/21 14:23", "Baxi Heating UK", "Baxi", "Ecoblue + 24 Combi ErP", "", "GC No. 47-077-08", "2015", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "20", "20", "", "", "88.5", "86.7", "", "77.6", "", "2", "", "", "104", "1", "2", "85", "3.5", "0", "", "", "", "0", "", "", "", "", "1", "6.786", "0.098", "0.0043", "0.65911", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "88.0", "98.0", "", "", "", "", "96.1"]} -{"pcdb_id": 17636, "brand_name": "Baxi", "model_name": "Ecoblue + 28 Combi ErP", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 86.7, "comparative_hot_water_efficiency_pct": 77.3, "output_kw_max": 24.0, "final_year_of_manufacture": null, "raw": ["017636", "000005", "0", "2015/Sep/21 14:23", "Baxi Heating UK", "Baxi", "Ecoblue + 28 Combi ErP", "", "GC No. 47-077-09", "2015", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "88.5", "86.7", "", "77.3", "", "2", "", "", "104", "1", "2", "90", "3.5", "0", "", "", "", "0", "", "", "", "", "1", "6.813", "0.098", "0.0044", "0.68225", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "87.9", "98.0", "", "", "", "", "96.1"]} -{"pcdb_id": 17637, "brand_name": "Baxi", "model_name": "Ecoblue + 33 Combi ErP", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 86.7, "comparative_hot_water_efficiency_pct": 77.2, "output_kw_max": 28.0, "final_year_of_manufacture": null, "raw": ["017637", "000005", "0", "2015/Sep/21 14:23", "Baxi Heating UK", "Baxi", "Ecoblue + 33 Combi ErP", "", "GC No. 47-077-10", "2015", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28", "28", "", "", "88.5", "86.7", "", "77.2", "", "2", "", "", "104", "1", "2", "95", "3.5", "0", "", "", "", "0", "", "", "", "", "1", "6.821", "0.086", "0.0045", "0.69191", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "88.0", "98.1", "", "", "", "", "96.2"]} -{"pcdb_id": 17638, "brand_name": "Baxi", "model_name": "Ecoblue 12 System ErP", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 12.0, "final_year_of_manufacture": null, "raw": ["017638", "000005", "0", "2015/Sep/21 14:23", "Baxi Heating UK", "Baxi", "Ecoblue 12 System ErP", "", "GC No. 41-470-23", "2015", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "12", "12", "", "", "88.6", "79.6", "", "58.1", "", "2", "", "", "102", "1", "2", "75", "3.5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "88.1", "98.2", "", "", "", "", "96.3"]} -{"pcdb_id": 17639, "brand_name": "Baxi", "model_name": "Ecoblue 15 System ErP", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 15.0, "final_year_of_manufacture": null, "raw": ["017639", "000005", "0", "2015/Sep/21 14:23", "Baxi Heating UK", "Baxi", "Ecoblue 15 System ErP", "", "GC No. 41-470-24", "2015", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "15", "15", "", "", "88.5", "79.5", "", "58.1", "", "2", "", "", "102", "1", "2", "80", "3.5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "88.0", "98.1", "", "", "", "", "96.2"]} -{"pcdb_id": 17640, "brand_name": "Baxi", "model_name": "Ecoblue18 System ErP", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 18.0, "final_year_of_manufacture": null, "raw": ["017640", "000005", "0", "2015/Sep/21 14:23", "Baxi Heating UK", "Baxi", "Ecoblue18 System ErP", "", "GC No. 41-470-25", "2015", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18", "18", "", "", "88.5", "79.5", "", "58.1", "", "2", "", "", "102", "1", "2", "80", "3.5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "88.0", "98.1", "", "", "", "", "96.2"]} -{"pcdb_id": 17641, "brand_name": "Baxi", "model_name": "Ecoblue 24 System ErP", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 24.0, "final_year_of_manufacture": null, "raw": ["017641", "000005", "0", "2015/Sep/21 14:23", "Baxi Heating UK", "Baxi", "Ecoblue 24 System ErP", "", "GC No. 41-470-26", "2015", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24", "24", "", "", "88.5", "79.5", "", "58.1", "", "2", "", "", "102", "1", "2", "85", "3.5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "87.9", "98.0", "", "", "", "", "96.1"]} -{"pcdb_id": 17642, "brand_name": "Baxi", "model_name": "Ecoblue 28 System ErP", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 28.0, "final_year_of_manufacture": null, "raw": ["017642", "000005", "0", "2015/Sep/21 14:23", "Baxi Heating UK", "Baxi", "Ecoblue 28 System ErP", "", "GC No. 41-470-27", "2015", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "28", "28", "", "", "88.5", "79.5", "", "58.1", "", "2", "", "", "102", "1", "2", "90", "3.5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "87.9", "98.0", "", "", "", "", "96.1"]} -{"pcdb_id": 17643, "brand_name": "Baxi", "model_name": "Ecoblue 32 System ErP", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 32.0, "final_year_of_manufacture": null, "raw": ["017643", "000005", "0", "2015/Sep/21 14:23", "Baxi Heating UK", "Baxi", "Ecoblue 32 System ErP", "", "GC No. 41-470-28", "2015", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "32", "32", "", "", "88.5", "79.5", "", "58.1", "", "2", "", "", "102", "1", "2", "90", "3.5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "87.9", "98.0", "", "", "", "", "96.1"]} -{"pcdb_id": 17644, "brand_name": "Vaillant", "model_name": "ecoTEC plus 825 H combi A", "model_qualifier": "VUW GB 256/5-5", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 87.0, "comparative_hot_water_efficiency_pct": 76.1, "output_kw_max": 19.3, "final_year_of_manufacture": 2017, "raw": ["017644", "000031", "0", "2019/Mar/04 11:01", "Vaillant Group UK", "Vaillant", "ecoTEC plus 825 H combi A", "VUW GB 256/5-5", "47-044-57", "2015", "2017", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "19.3", "19.3", "", "", "88.5", "87.0", "", "76.1", "", "2", "", "", "104", "1", "2", "31", "2", "0", "", "", "", "0", "", "", "", "", "1", "6.923", "0.12", "0.003", "0.81911", "", "", "", "", "", "1", "1", "", "0045", "", "", "", "", "", "", "", "", "88.8", "97.8", "", "", "", "", "96.1"]} -{"pcdb_id": 17645, "brand_name": "Vaillant", "model_name": "ecoTEC pro 24 H combi A", "model_qualifier": "VUW 246/5-3 A", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 87.0, "comparative_hot_water_efficiency_pct": 76.3, "output_kw_max": 18.9, "final_year_of_manufacture": 2017, "raw": ["017645", "000031", "0", "2019/Mar/04 11:05", "Vaillant Group UK", "Vaillant", "ecoTEC pro 24 H combi A", "VUW 246/5-3 A", "47-044-54", "2015", "2017", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "18.9", "18.9", "", "", "88.5", "87.0", "", "76.3", "", "2", "", "", "104", "1", "2", "32", "2", "0", "", "", "", "0", "", "", "", "", "1", "6.904", "0.129", "0.003", "0.80529", "", "", "", "", "", "1", "1", "", "0045", "", "", "", "", "", "", "", "", "89.0", "97.8", "", "", "", "", "96.1"]} -{"pcdb_id": 17646, "brand_name": "Vokera", "model_name": "Vision", "model_qualifier": "25S", "winter_efficiency_pct": 89.7, "summer_efficiency_pct": 80.7, "comparative_hot_water_efficiency_pct": 58.9, "output_kw_max": 23.74, "final_year_of_manufacture": null, "raw": ["017646", "000011", "0", "2015/Jul/15 16:41", "Vokera", "Vokera", "Vision", "25S", "41 094 86", "2014", "current", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "23.74", "23.74", "", "", "89.7", "80.7", "", "58.9", "", "2", "0", "", "102", "1", "2", "77", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.1", "98.0", "", "", "", "", "96.5"]} -{"pcdb_id": 17647, "brand_name": "Baxi", "model_name": "Megaflo 15 System ErP", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 15.0, "final_year_of_manufacture": null, "raw": ["017647", "000005", "0", "2015/Jul/16 11:26", "Baxi Heating UK", "Baxi", "Megaflo 15 System ErP", "", "GC No. 41-470-18", "2015", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "15", "15", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "95", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "87.9", "96.8", "", "", "", "", "95.1"]} -{"pcdb_id": 17648, "brand_name": "Baxi", "model_name": "Megaflo 18 System ErP", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 18.0, "final_year_of_manufacture": null, "raw": ["017648", "000005", "0", "2015/Jul/16 11:27", "Baxi Heating UK", "Baxi", "Megaflo 18 System ErP", "", "GC No. 41-470-19", "2015", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18", "18", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "105", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "87.9", "96.9", "", "", "", "", "95.2"]} -{"pcdb_id": 17649, "brand_name": "Baxi", "model_name": "Megaflo 24 System ErP", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 24.0, "final_year_of_manufacture": null, "raw": ["017649", "000005", "0", "2015/Jul/16 11:27", "Baxi Heating UK", "Baxi", "Megaflo 24 System ErP", "", "GC No. 41-470-20", "2015", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24", "24", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "115", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "87.9", "96.9", "", "", "", "", "95.2"]} -{"pcdb_id": 17650, "brand_name": "Baxi", "model_name": "Megaflo 28 System ErP", "model_qualifier": "", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 78.9, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 24.0, "final_year_of_manufacture": null, "raw": ["017650", "000005", "0", "2015/Jul/16 11:27", "Baxi Heating UK", "Baxi", "Megaflo 28 System ErP", "", "GC No. 41-470-21", "2015", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24", "24", "", "", "87.9", "78.9", "", "57.7", "", "2", "", "", "102", "1", "2", "125", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "87.9", "96.7", "", "", "", "", "95.0"]} -{"pcdb_id": 17651, "brand_name": "Baxi", "model_name": "Megaflo 32 System ErP", "model_qualifier": "", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 78.9, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 32.0, "final_year_of_manufacture": null, "raw": ["017651", "000005", "0", "2015/Jul/16 11:28", "Baxi Heating UK", "Baxi", "Megaflo 32 System ErP", "", "GC No. 41-470-22", "2015", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "32", "32", "", "", "87.9", "78.9", "", "57.7", "", "2", "", "", "102", "1", "2", "125", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "87.8", "96.7", "", "", "", "", "95.0"]} -{"pcdb_id": 17652, "brand_name": "Baxi", "model_name": "Megaflo 15 System IE ErP", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 15.0, "final_year_of_manufacture": null, "raw": ["017652", "000005", "0", "2015/Jul/16 11:28", "Baxi Heating UK", "Baxi", "Megaflo 15 System IE ErP", "", "", "2015", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "15", "15", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "95", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "96.8", "", "", "", "", "95.1"]} -{"pcdb_id": 17653, "brand_name": "Baxi", "model_name": "Megaflo 18 System IE ErP", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 18.0, "final_year_of_manufacture": null, "raw": ["017653", "000005", "0", "2015/Jul/16 11:29", "Baxi Heating UK", "Baxi", "Megaflo 18 System IE ErP", "", "", "2015", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18", "18", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "105", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "96.9", "", "", "", "", "95.2"]} -{"pcdb_id": 17654, "brand_name": "Baxi", "model_name": "Megaflo 24 System IE ErP", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 24.0, "final_year_of_manufacture": null, "raw": ["017654", "000005", "0", "2015/Jul/16 11:30", "Baxi Heating UK", "Baxi", "Megaflo 24 System IE ErP", "", "", "2015", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24", "24", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "115", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "96.9", "", "", "", "", "95.2"]} -{"pcdb_id": 17655, "brand_name": "Baxi", "model_name": "Platinum 24 Combi ErP", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 86.7, "comparative_hot_water_efficiency_pct": 73.5, "output_kw_max": 20.0, "final_year_of_manufacture": null, "raw": ["017655", "000005", "0", "2015/Sep/21 14:23", "Baxi Heating UK", "Baxi", "Platinum 24 Combi ErP", "", "GC No. 47-077-04", "2015", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "20", "20", "", "", "88.0", "86.7", "", "73.5", "", "2", "", "", "104", "1", "2", "85", "5", "0", "", "", "0", "0", "", "", "", "", "1", "7.163", "0.085", "0.0065", "1.00715", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "87.9", "96.9", "", "", "", "", "95.2"]} -{"pcdb_id": 17656, "brand_name": "Baxi", "model_name": "Platinum 28 Combi ErP", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 86.7, "comparative_hot_water_efficiency_pct": 73.4, "output_kw_max": 24.0, "final_year_of_manufacture": null, "raw": ["017656", "000005", "0", "2017/Sep/15 11:43", "Baxi Heating UK", "Baxi", "Platinum 28 Combi ErP", "", "GC No. 47-077-05", "2015", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "88.0", "86.7", "", "73.4", "", "2", "", "", "104", "1", "2", "120", "5", "0", "", "", "", "0", "", "", "", "", "1", "7.17", "0.093", "0.0072", "1.00979", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "87.9", "96.9", "", "", "", "", "95.2"]} -{"pcdb_id": 17657, "brand_name": "Baxi", "model_name": "Platinum 33 Combi ErP", "model_qualifier": "", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 86.7, "comparative_hot_water_efficiency_pct": 71.1, "output_kw_max": 28.0, "final_year_of_manufacture": null, "raw": ["017657", "000005", "0", "2015/Sep/21 14:23", "Baxi Heating UK", "Baxi", "Platinum 33 Combi ErP", "", "GC No. 47-077-06", "2015", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28", "28", "", "", "87.9", "86.7", "", "71.1", "", "2", "", "", "104", "1", "2", "125", "5", "0", "", "", "", "0", "", "", "", "", "1", "7.406", "0.092", "0.0047", "1.25141", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "87.9", "96.7", "", "", "", "", "95.0"]} -{"pcdb_id": 17658, "brand_name": "Baxi", "model_name": "Platinum 40 Combi ErP", "model_qualifier": "", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 86.6, "comparative_hot_water_efficiency_pct": 68.9, "output_kw_max": 32.0, "final_year_of_manufacture": null, "raw": ["017658", "000005", "0", "2015/Sep/21 14:23", "Baxi Heating UK", "Baxi", "Platinum 40 Combi ErP", "", "GC No. 47-077-07", "2015", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "32", "32", "", "", "87.9", "86.6", "", "68.9", "", "2", "", "", "104", "1", "2", "125", "5", "0", "", "", "", "0", "", "", "", "", "1", "7.649", "0.114", "0.0048", "1.48176", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "87.8", "96.7", "", "", "", "", "95.0"]} -{"pcdb_id": 17659, "brand_name": "Baxi", "model_name": "Duo-tec 24 Combi ErP", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 86.7, "comparative_hot_water_efficiency_pct": 73.5, "output_kw_max": 20.0, "final_year_of_manufacture": null, "raw": ["017659", "000005", "0", "2015/Sep/21 14:23", "Baxi Heating UK", "Baxi", "Duo-tec 24 Combi ErP", "", "GC No. 47-075-96", "2015", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "20", "20", "", "", "88.0", "86.7", "", "73.5", "", "2", "", "", "104", "1", "2", "85", "5", "0", "", "", "", "0", "", "", "", "", "1", "7.163", "0.085", "0.0065", "1.00715", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "87.9", "96.9", "", "", "", "", "95.2"]} -{"pcdb_id": 17660, "brand_name": "Baxi", "model_name": "Duo-tec 28 Combi ErP", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 86.7, "comparative_hot_water_efficiency_pct": 73.4, "output_kw_max": 24.0, "final_year_of_manufacture": null, "raw": ["017660", "000005", "0", "2015/Sep/21 14:23", "Baxi Heating UK", "Baxi", "Duo-tec 28 Combi ErP", "", "GC No. 47-075-97", "2015", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "88.0", "86.7", "", "73.4", "", "2", "", "", "104", "1", "2", "120", "5", "0", "", "", "", "0", "", "", "", "", "1", "7.17", "0.093", "0.0072", "1.00979", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "87.9", "96.9", "", "", "", "", "95.2"]} -{"pcdb_id": 17662, "brand_name": "Baxi", "model_name": "DUO-TEC 28 LPG COMBI ErP", "model_qualifier": "", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.4, "comparative_hot_water_efficiency_pct": 56.6, "output_kw_max": 24.0, "final_year_of_manufacture": null, "raw": ["017662", "000005", "0", "2016/Jul/20 13:47", "Baxi Heating UK", "Baxi", "DUO-TEC 28 LPG COMBI ErP", "", "47-075-98", "2015", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "89.0", "80.4", "", "56.6", "", "2", "1", "", "104", "1", "2", "42", "3", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.9", "99.0", "", "", "", "", "97.3"]} -{"pcdb_id": 17663, "brand_name": "Baxi", "model_name": "Duo-tec 33 Combi ErP", "model_qualifier": "", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 86.7, "comparative_hot_water_efficiency_pct": 71.1, "output_kw_max": 28.0, "final_year_of_manufacture": null, "raw": ["017663", "000005", "0", "2015/Sep/21 14:23", "Baxi Heating UK", "Baxi", "Duo-tec 33 Combi ErP", "", "GC No. 47-075-99", "2015", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28", "28", "", "", "87.9", "86.7", "", "71.1", "", "2", "", "", "104", "1", "2", "125", "5", "0", "", "", "", "0", "", "", "", "", "1", "7.406", "0.092", "0.0047", "1.25141", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "87.9", "96.7", "", "", "", "", "95.0"]} -{"pcdb_id": 17664, "brand_name": "Baxi", "model_name": "Duo-tec 40 Combi ErP", "model_qualifier": "", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 86.6, "comparative_hot_water_efficiency_pct": 68.9, "output_kw_max": 32.0, "final_year_of_manufacture": null, "raw": ["017664", "000005", "0", "2015/Sep/21 14:23", "Baxi Heating UK", "Baxi", "Duo-tec 40 Combi ErP", "", "GC No. 47-077-03", "2015", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "32", "32", "", "", "87.9", "86.6", "", "68.9", "", "2", "", "", "104", "1", "2", "125", "5", "0", "", "", "", "0", "", "", "", "", "1", "7.649", "0.114", "0.0048", "1.48176", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "87.8", "96.7", "", "", "", "", "95.0"]} -{"pcdb_id": 17665, "brand_name": "Baxi", "model_name": "EcoBlue 12 Heat ErP", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 13.0, "final_year_of_manufacture": null, "raw": ["017665", "000005", "0", "2015/Jul/20 10:14", "Baxi Heating UK", "Baxi", "EcoBlue 12 Heat ErP", "", "41-470-29", "2014", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "13", "13", "", "", "88.5", "79.5", "", "58.1", "", "2", "", "", "102", "1", "2", "17", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "98.0", "", "", "", "", "96.1"]} -{"pcdb_id": 17666, "brand_name": "Baxi", "model_name": "EcoBlue 15 Heat ErP", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 16.0, "final_year_of_manufacture": null, "raw": ["017666", "000005", "0", "2015/Aug/14 08:58", "Baxi Heating UK", "Baxi", "EcoBlue 15 Heat ErP", "", "41-470-30", "2014", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "16", "16", "", "", "88.5", "79.5", "", "58.1", "", "2", "", "", "102", "1", "2", "20", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "98.0", "", "", "", "", "96.1"]} -{"pcdb_id": 17667, "brand_name": "Baxi", "model_name": "EcoBlue 18 Heat ErP", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 19.0, "final_year_of_manufacture": null, "raw": ["017667", "000005", "0", "2015/Aug/14 09:18", "Baxi Heating UK", "Baxi", "EcoBlue 18 Heat ErP", "", "41-470-31", "2014", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "19", "19", "", "", "88.5", "79.5", "", "58.0", "", "2", "", "", "102", "1", "2", "23", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "98.0", "", "", "", "", "96.1"]} -{"pcdb_id": 17668, "brand_name": "Baxi", "model_name": "EcoBlue 21 Heat ErP", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 21.0, "final_year_of_manufacture": null, "raw": ["017668", "000005", "0", "2015/Aug/14 09:19", "Baxi Heating UK", "Baxi", "EcoBlue 21 Heat ErP", "", "41-470-32", "2014", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "21", "21", "", "", "88.5", "79.5", "", "58.0", "", "2", "", "", "102", "1", "2", "25", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "98.0", "", "", "", "", "96.1"]} -{"pcdb_id": 17669, "brand_name": "Baxi", "model_name": "EcoBlue 24 Heat ErP", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 25.0, "final_year_of_manufacture": null, "raw": ["017669", "000005", "0", "2015/Aug/14 09:26", "Baxi Heating UK", "Baxi", "EcoBlue 24 Heat ErP", "", "41-470-33", "2014", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "25", "25", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "33", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.7", "98.0", "", "", "", "", "96.1"]} -{"pcdb_id": 17670, "brand_name": "Baxi", "model_name": "EcoBlue Advance 13 Heat ErP", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 13.0, "final_year_of_manufacture": null, "raw": ["017670", "000005", "0", "2015/Jul/20 10:26", "Baxi Heating UK", "Baxi", "EcoBlue Advance 13 Heat ErP", "", "41-470-34", "2014", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "13", "13", "", "", "88.5", "79.5", "", "58.1", "", "2", "", "", "102", "1", "2", "17", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "98.0", "", "", "", "", "96.1"]} -{"pcdb_id": 17671, "brand_name": "Baxi", "model_name": "EcoBlue Advance 16 Heat ErP", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 16.0, "final_year_of_manufacture": null, "raw": ["017671", "000005", "0", "2015/Aug/14 09:27", "Baxi Heating UK", "Baxi", "EcoBlue Advance 16 Heat ErP", "", "41-470-35", "2014", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "16", "16", "", "", "88.5", "79.5", "", "58.1", "", "2", "", "", "102", "1", "2", "20", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "98.0", "", "", "", "", "96.1"]} -{"pcdb_id": 17672, "brand_name": "Baxi", "model_name": "EcoBlue Advance 19 Heat ErP", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 19.0, "final_year_of_manufacture": null, "raw": ["017672", "000005", "0", "2015/Aug/14 09:28", "Baxi Heating UK", "Baxi", "EcoBlue Advance 19 Heat ErP", "", "41-470-36", "2014", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "19", "19", "", "", "88.5", "79.5", "", "58.0", "", "2", "", "", "102", "1", "2", "23", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "98.0", "", "", "", "", "96.1"]} -{"pcdb_id": 17673, "brand_name": "Baxi", "model_name": "EcoBlue Advance 25 Heat ErP", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 25.0, "final_year_of_manufacture": null, "raw": ["017673", "000005", "0", "2015/Aug/14 09:28", "Baxi Heating UK", "Baxi", "EcoBlue Advance 25 Heat ErP", "", "41-470-37", "2014", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "25", "25", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "33", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.7", "98.0", "", "", "", "", "96.1"]} -{"pcdb_id": 17674, "brand_name": "Baxi", "model_name": "EcoBlue Advance 30 Heat ErP", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 30.0, "final_year_of_manufacture": null, "raw": ["017674", "000005", "0", "2015/Aug/14 09:32", "Baxi Heating UK", "Baxi", "EcoBlue Advance 30 Heat ErP", "", "41-470-38", "2014", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "30", "30", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "44", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.5", "98.0", "", "", "", "", "96.0"]} -{"pcdb_id": 17675, "brand_name": "Baxi", "model_name": "MainEco 15 Heat ErP", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 16.0, "final_year_of_manufacture": null, "raw": ["017675", "000005", "0", "2015/Jul/20 10:39", "Baxi Heating UK", "Baxi", "MainEco 15 Heat ErP", "", "41-470-**", "2014", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "1", "16.0", "16.0", "", "", "88.5", "79.5", "", "58.1", "", "2", "", "", "102", "1", "2", "20", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "98.0", "", "", "", "", "96.1"]} -{"pcdb_id": 17676, "brand_name": "Baxi", "model_name": "MainEco 18 Heat ErP", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 19.0, "final_year_of_manufacture": null, "raw": ["017676", "000005", "0", "2015/Jul/20 10:40", "Baxi Heating UK", "Baxi", "MainEco 18 Heat ErP", "", "41-470-**", "2014", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "19.0", "19.0", "", "", "88.5", "79.5", "", "58.0", "", "2", "", "", "102", "1", "2", "23", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "98.0", "", "", "", "", "96.1"]} -{"pcdb_id": 17677, "brand_name": "Baxi", "model_name": "MainEco 24 Heat ErP", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 25.0, "final_year_of_manufacture": null, "raw": ["017677", "000005", "0", "2015/Jul/20 10:42", "Baxi Heating UK", "Baxi", "MainEco 24 Heat ErP", "", "41-470-**", "2014", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "25.0", "25.0", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "33", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.7", "98.0", "", "", "", "", "96.1"]} -{"pcdb_id": 17678, "brand_name": "Baxi", "model_name": "Precision+ ErP", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 30.0, "final_year_of_manufacture": null, "raw": ["017678", "000005", "0", "2015/Jul/20 10:43", "Baxi Heating UK", "Baxi", "Precision+ ErP", "", "41-470-39", "2014", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "12", "30", "", "", "88.5", "79.5", "", "58.0", "", "2", "", "", "102", "1", "2", "44", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "98.0", "", "", "", "", "96.1"]} -{"pcdb_id": 17679, "brand_name": "Vaillant", "model_name": "ecoTEC plus 832 H combi A", "model_qualifier": "VUW GB 326/5-5", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 87.0, "comparative_hot_water_efficiency_pct": 74.4, "output_kw_max": 24.4, "final_year_of_manufacture": 2017, "raw": ["017679", "000031", "0", "2019/Mar/04 11:01", "Vaillant Group UK", "Vaillant", "ecoTEC plus 832 H combi A", "VUW GB 326/5-5", "47-044-58", "2015", "2017", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.4", "24.4", "", "", "88.7", "87.0", "", "74.4", "", "2", "", "", "104", "1", "2", "31", "2", "0", "", "", "0", "0", "", "", "", "", "1", "7.074", "0.119", "0.003", "0.96947", "0.0", "0.0", "", "", "", "1", "1", "", "0045", "", "", "", "", "", "", "", "", "89.0", "98.2", "", "", "", "", "96.5"]} -{"pcdb_id": 17680, "brand_name": "Vaillant", "model_name": "ecoTEC plus 832 LPG combi A", "model_qualifier": "VUW GB 326/5-5 R4", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 62.2, "output_kw_max": 24.4, "final_year_of_manufacture": 2017, "raw": ["017680", "000031", "0", "2019/Mar/04 11:03", "Vaillant Group UK", "Vaillant", "ecoTEC plus 832 LPG combi A", "VUW GB 326/5-5 R4", "47-044-59", "2015", "2017", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24.4", "24.4", "", "", "88.3", "79.7", "", "62.2", "", "2", "1", "", "104", "1", "2", "85", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "", "0045", "", "", "", "", "", "", "", "", "89.4", "97.3", "", "", "", "", "95.8"]} -{"pcdb_id": 17681, "brand_name": "Vaillant", "model_name": "ecoTEC plus 838 H combi A", "model_qualifier": "VUW GB 386/5-5", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 87.0, "comparative_hot_water_efficiency_pct": 73.9, "output_kw_max": 28.6, "final_year_of_manufacture": 2017, "raw": ["017681", "000031", "0", "2019/Mar/04 11:04", "Vaillant Group UK", "Vaillant", "ecoTEC plus 838 H combi A", "VUW GB 386/5-5", "47-044-60", "2015", "2017", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28.6", "28.6", "", "", "88.7", "87.0", "", "73.9", "", "2", "", "", "104", "1", "2", "38", "3", "0", "", "", "", "0", "", "", "", "", "1", "7.122", "0.126", "0.003", "1.01583", "", "", "", "", "", "1", "1", "", "0045", "", "", "", "", "", "", "", "", "89.0", "98.2", "", "", "", "", "96.5"]} -{"pcdb_id": 17682, "brand_name": "Vaillant", "model_name": "ecoTEC plus 938 H combi A", "model_qualifier": "VUI GB 386/5-5 A", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 87.0, "comparative_hot_water_efficiency_pct": 65.8, "output_kw_max": 28.6, "final_year_of_manufacture": 2017, "raw": ["017682", "000031", "0", "2019/Mar/04 11:04", "Vaillant Group UK", "Vaillant", "ecoTEC plus 938 H combi A", "VUI GB 386/5-5 A", "47-044-61", "2015", "2017", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28.6", "28.6", "", "", "88.7", "87.0", "", "65.8", "", "2", "", "", "104", "1", "2", "27", "5", "0", "", "", "", "0", "", "", "", "", "1", "7.998", "0.214", "0.0", "1.8794", "", "", "", "", "", "1", "1", "", "0045", "", "", "", "", "", "", "", "", "89.0", "98.2", "", "", "", "", "96.5"]} -{"pcdb_id": 17683, "brand_name": "Vaillant", "model_name": "ecoTEC pro 28 H combi A", "model_qualifier": "VUW GB 286/5-3 A", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 87.0, "comparative_hot_water_efficiency_pct": 71.0, "output_kw_max": 18.9, "final_year_of_manufacture": 2017, "raw": ["017683", "000031", "0", "2019/Mar/04 11:05", "Vaillant Group UK", "Vaillant", "ecoTEC pro 28 H combi A", "VUW GB 286/5-3 A", "47-044-55", "2015", "2017", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "18.9", "18.9", "", "", "88.5", "87.0", "", "71.0", "", "2", "", "", "104", "1", "2", "32", "2", "0", "", "", "", "0", "", "", "", "", "1", "7.418", "0.103", "0.0017", "1.30916", "", "", "", "", "", "1", "1", "", "0045", "", "", "", "", "", "", "", "", "89.0", "97.8", "", "", "", "", "96.1"]} -{"pcdb_id": 17684, "brand_name": "Vaillant", "model_name": "ecoTEC plus 612 H system A", "model_qualifier": "VU GB 126/5-5 A", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 12.2, "final_year_of_manufacture": 2017, "raw": ["017684", "000031", "0", "2019/Mar/04 10:56", "Vaillant Group UK", "Vaillant", "ecoTEC plus 612 H system A", "VU GB 126/5-5 A", "41-044-78", "2015", "2017", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "12.2", "12.2", "", "", "88.3", "79.3", "", "57.9", "", "2", "", "", "102", "1", "2", "18", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0045", "", "", "", "", "", "", "", "", "88.7", "97.3", "", "", "", "", "95.7"]} -{"pcdb_id": 17685, "brand_name": "Vaillant", "model_name": "ecoTEC plus 615 H system A", "model_qualifier": "VU GB 156/5-5 A", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 15.4, "final_year_of_manufacture": 2017, "raw": ["017685", "000031", "0", "2019/Mar/04 10:56", "Vaillant Group UK", "Vaillant", "ecoTEC plus 615 H system A", "VU GB 156/5-5 A", "41-044-79", "2015", "2017", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "15.4", "15.4", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "31", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0045", "", "", "", "", "", "", "", "", "89.4", "97.3", "", "", "", "", "95.8"]} -{"pcdb_id": 17686, "brand_name": "Vaillant", "model_name": "ecoTEC plus 618 H system A", "model_qualifier": "VU GB 186/5-5 A", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 18.5, "final_year_of_manufacture": 2017, "raw": ["017686", "000031", "0", "2019/Mar/04 10:56", "Vaillant Group UK", "Vaillant", "ecoTEC plus 618 H system A", "VU GB 186/5-5 A", "41-044-80", "2015", "2017", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18.5", "18.5", "", "", "88.6", "79.6", "", "58.2", "", "2", "", "", "102", "1", "2", "31", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0045", "", "", "", "", "", "", "", "", "89.5", "97.8", "", "", "", "", "96.2"]} -{"pcdb_id": 17687, "brand_name": "Vaillant", "model_name": "ecoTEC pro 28 LPG combi A", "model_qualifier": "VUW GB 286/5-3 A R4", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 62.1, "output_kw_max": 18.9, "final_year_of_manufacture": 2017, "raw": ["017687", "000031", "0", "2019/Mar/04 11:06", "Vaillant Group UK", "Vaillant", "ecoTEC pro 28 LPG combi A", "VUW GB 286/5-3 A R4", "47-044-56", "2015", "2017", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "18.9", "18.9", "", "", "88.2", "79.6", "", "62.1", "", "2", "1", "", "104", "1", "2", "80", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "", "0045", "", "", "", "", "", "", "", "", "89.5", "97.0", "", "", "", "", "95.6"]} -{"pcdb_id": 17688, "brand_name": "Vaillant", "model_name": "ecoTEC pro 30 H combi A", "model_qualifier": "VUW GB 306/5-3", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 87.0, "comparative_hot_water_efficiency_pct": 73.2, "output_kw_max": 24.7, "final_year_of_manufacture": null, "raw": ["017688", "000031", "0", "2015/Sep/21 14:23", "Vaillant Group UK", "Vaillant", "ecoTEC pro 30 H combi A", "VUW GB 306/5-3", "47-044-52", "2015", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.7", "24.7", "", "", "88.7", "87.0", "", "73.2", "", "2", "", "", "104", "1", "2", "38", "3", "0", "", "", "", "0", "", "", "", "", "1", "7.195", "0.095", "0.0008", "1.09904", "", "", "", "", "", "", "", "", "0045", "", "", "", "", "", "", "", "", "89.0", "98.0", "", "", "", "", "96.3"]} -{"pcdb_id": 17689, "brand_name": "Vaillant", "model_name": "ecoTEC plus 618 LPG system A", "model_qualifier": "VU GB 186/5-5 A R4", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 18.5, "final_year_of_manufacture": 2017, "raw": ["017689", "000031", "0", "2019/Mar/04 10:57", "Vaillant Group UK", "Vaillant", "ecoTEC plus 618 LPG system A", "VU GB 186/5-5 A R4", "41-044-81", "2015", "2017", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "18.5", "18.5", "", "", "88.4", "79.4", "", "58.0", "", "2", "1", "", "102", "1", "2", "65", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0045", "", "", "", "", "", "", "", "", "89.7", "97.5", "", "", "", "", "96.0"]} -{"pcdb_id": 17690, "brand_name": "Vaillant", "model_name": "ecoTEC plus 624 H system A", "model_qualifier": "VU GB 246/5-5 A", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 24.4, "final_year_of_manufacture": 2017, "raw": ["017690", "000031", "0", "2019/Mar/04 10:57", "Vaillant Group UK", "Vaillant", "ecoTEC plus 624 H system A", "VU GB 246/5-5 A", "41-044-82", "2015", "2017", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24.4", "24.4", "", "", "88.7", "79.7", "", "58.2", "", "2", "", "", "102", "1", "2", "31", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0045", "", "", "", "", "", "", "", "", "89.0", "98.2", "", "", "", "", "96.5"]} -{"pcdb_id": 17691, "brand_name": "Vaillant", "model_name": "ecoTEC plus 630 H system A", "model_qualifier": "VU GB 306/5-5 A", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 30.4, "final_year_of_manufacture": 2017, "raw": ["017691", "000031", "0", "2019/Mar/04 10:57", "Vaillant Group UK", "Vaillant", "ecoTEC plus 630 H system A", "VU GB 306/5-5 A", "41-044-83", "2015", "2017", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "30.4", "30.4", "", "", "88.7", "79.7", "", "58.2", "", "2", "", "", "102", "1", "2", "34", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0045", "", "", "", "", "", "", "", "", "88.7", "98.2", "", "", "", "", "96.4"]} -{"pcdb_id": 17692, "brand_name": "Vaillant", "model_name": "ecoTEC plus 630 LPG system A", "model_qualifier": "VU GB 306/5-5 A R4", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 30.4, "final_year_of_manufacture": 2017, "raw": ["017692", "000031", "0", "2019/Mar/04 11:00", "Vaillant Group UK", "Vaillant", "ecoTEC plus 630 LPG system A", "VU GB 306/5-5 A R4", "41-044-84", "2015", "2017", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "30.4", "30.4", "", "", "88.4", "79.4", "", "58.0", "", "2", "1", "", "102", "1", "2", "80", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0045", "", "", "", "", "", "", "", "", "89.4", "97.6", "", "", "", "", "96.1"]} -{"pcdb_id": 17693, "brand_name": "Vaillant", "model_name": "ecoTEC plus 637 H system A", "model_qualifier": "VU GB 376/5-5 A", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 37.6, "final_year_of_manufacture": 2017, "raw": ["017693", "000031", "0", "2019/Mar/04 11:00", "Vaillant Group UK", "Vaillant", "ecoTEC plus 637 H system A", "VU GB 376/5-5 A", "41-044-85", "2015", "2017", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "37.6", "37.6", "", "", "88.5", "79.5", "", "58.1", "", "2", "", "", "102", "1", "2", "38", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0045", "", "", "", "", "", "", "", "", "88.8", "97.8", "", "", "", "", "96.1"]} -{"pcdb_id": 17694, "brand_name": "Potterton", "model_name": "Gold 24 Combi ErP", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 86.7, "comparative_hot_water_efficiency_pct": 73.5, "output_kw_max": 20.0, "final_year_of_manufacture": null, "raw": ["017694", "000005", "0", "2015/Sep/21 14:23", "Baxi Heating UK", "Potterton", "Gold 24 Combi ErP", "", "GC No. 47-393-43", "2015", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "20", "20", "", "", "88.0", "86.7", "", "73.5", "", "2", "", "", "104", "1", "2", "85", "5", "0", "", "", "", "0", "", "", "", "", "1", "7.163", "0.085", "0.0065", "1.00715", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "87.9", "96.9", "", "", "", "", "95.2"]} -{"pcdb_id": 17695, "brand_name": "Potterton", "model_name": "Gold 28 Combi ErP", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 86.7, "comparative_hot_water_efficiency_pct": 73.4, "output_kw_max": 24.0, "final_year_of_manufacture": null, "raw": ["017695", "000005", "0", "2015/Sep/21 14:23", "Baxi Heating UK", "Potterton", "Gold 28 Combi ErP", "", "GC No. 47-393-44", "2015", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "88.0", "86.7", "", "73.4", "", "2", "", "", "104", "1", "2", "120", "5", "0", "", "", "", "0", "", "", "", "", "1", "7.17", "0.093", "0.0072", "1.00979", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "87.9", "96.9", "", "", "", "", "95.2"]} -{"pcdb_id": 17696, "brand_name": "Potterton", "model_name": "Gold 33 Combi ErP", "model_qualifier": "", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 86.7, "comparative_hot_water_efficiency_pct": 71.1, "output_kw_max": 28.0, "final_year_of_manufacture": null, "raw": ["017696", "000005", "0", "2015/Sep/21 14:23", "Baxi Heating UK", "Potterton", "Gold 33 Combi ErP", "", "GC No. 47-393-46", "2015", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28", "28", "", "", "87.9", "86.7", "", "71.1", "", "2", "", "", "104", "1", "2", "125", "5", "0", "", "", "", "0", "", "", "", "", "1", "7.406", "0.092", "0.0047", "1.25141", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "87.9", "96.7", "", "", "", "", "95.0"]} -{"pcdb_id": 17697, "brand_name": "Potterton", "model_name": "GOLD 28 LPG COMBI ErP", "model_qualifier": "", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.4, "comparative_hot_water_efficiency_pct": 56.6, "output_kw_max": 24.0, "final_year_of_manufacture": null, "raw": ["017697", "000005", "0", "2016/Jul/20 13:46", "Baxi Heating UK", "Potterton", "GOLD 28 LPG COMBI ErP", "", "47-393-45", "2015", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "89.0", "80.4", "", "56.6", "", "2", "1", "", "104", "1", "2", "42", "3", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.9", "99.0", "", "", "", "", "97.3"]} -{"pcdb_id": 17698, "brand_name": "Potterton", "model_name": "Gold 18 System ErP", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 18.0, "final_year_of_manufacture": null, "raw": ["017698", "000005", "0", "2015/Jul/17 13:42", "Baxi Heating UK", "Potterton", "Gold 18 System ErP", "", "GC No. 41-592-39", "2015", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18", "18", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "105", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "96.9", "", "", "", "", "95.2"]} -{"pcdb_id": 17699, "brand_name": "Potterton", "model_name": "Gold 24 System ErP", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 24.0, "final_year_of_manufacture": null, "raw": ["017699", "000005", "0", "2015/Jul/17 13:42", "Baxi Heating UK", "Potterton", "Gold 24 System ErP", "", "GC No.41-592-40", "2015", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24", "24", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "115", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "96.9", "", "", "", "", "95.2"]} -{"pcdb_id": 17700, "brand_name": "Potterton", "model_name": "Gold 28 System ErP", "model_qualifier": "", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 78.9, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 28.0, "final_year_of_manufacture": null, "raw": ["017700", "000005", "0", "2015/Jul/17 13:43", "Baxi Heating UK", "Potterton", "Gold 28 System ErP", "", "GC No. 41-592-41", "2015", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "28", "28", "", "", "87.9", "78.9", "", "57.7", "", "2", "", "", "102", "1", "2", "125", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "96.7", "", "", "", "", "95.0"]} -{"pcdb_id": 17701, "brand_name": "Potterton", "model_name": "Titanium 24 Combi ErP", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 86.7, "comparative_hot_water_efficiency_pct": 73.5, "output_kw_max": 20.0, "final_year_of_manufacture": null, "raw": ["017701", "000005", "0", "2015/Sep/21 14:23", "Baxi Heating UK", "Potterton", "Titanium 24 Combi ErP", "", "GC No. 47-393-50", "2015", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "20", "20", "", "", "88.0", "86.7", "", "73.5", "", "2", "", "", "104", "1", "2", "85", "5", "0", "", "", "", "0", "", "", "", "", "1", "7.163", "0.85", "0.0065", "1.00715", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "87.9", "96.9", "", "", "", "", "95.2"]} -{"pcdb_id": 17702, "brand_name": "Potterton", "model_name": "Titanium 28 Combi ErP", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 86.7, "comparative_hot_water_efficiency_pct": 73.4, "output_kw_max": 24.0, "final_year_of_manufacture": null, "raw": ["017702", "000005", "0", "2015/Sep/21 14:23", "Baxi Heating UK", "Potterton", "Titanium 28 Combi ErP", "", "GC No. 47-393-51", "2015", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "88.0", "86.7", "", "73.4", "", "2", "", "", "104", "1", "2", "120", "5", "0", "", "", "", "0", "", "", "", "", "1", "7.17", "0.093", "0.0072", "1.00979", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "87.9", "96.9", "", "", "", "", "95.2"]} -{"pcdb_id": 17703, "brand_name": "Potterton", "model_name": "Titanium 33 Combi ErP", "model_qualifier": "", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 86.7, "comparative_hot_water_efficiency_pct": 71.1, "output_kw_max": 28.0, "final_year_of_manufacture": null, "raw": ["017703", "000005", "0", "2015/Sep/21 14:23", "Baxi Heating UK", "Potterton", "Titanium 33 Combi ErP", "", "GC No. 47-393-52", "2015", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28", "28", "", "", "87.9", "86.7", "", "71.1", "", "2", "", "", "104", "1", "2", "125", "5", "0", "", "", "", "0", "", "", "", "", "1", "7.406", "0.092", "0.0047", "1.25141", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "87.9", "96.7", "", "", "", "", "95.0"]} -{"pcdb_id": 17704, "brand_name": "Potterton", "model_name": "Titanium 40 Combi ErP", "model_qualifier": "", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 86.6, "comparative_hot_water_efficiency_pct": 68.9, "output_kw_max": 32.0, "final_year_of_manufacture": null, "raw": ["017704", "000005", "0", "2015/Sep/21 14:23", "Baxi Heating UK", "Potterton", "Titanium 40 Combi ErP", "", "GC No. 47-393-53", "2015", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "32", "32", "", "", "87.9", "86.6", "", "68.9", "", "2", "", "", "104", "1", "2", "125", "5", "0", "", "", "", "0", "", "", "", "", "1", "7.649", "0.114", "0.0048", "1.48176", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "87.8", "96.7", "", "", "", "", "95.0"]} -{"pcdb_id": 17705, "brand_name": "Viessmann", "model_name": "Vitodens 200-W B2HA-19", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 17.5, "final_year_of_manufacture": null, "raw": ["017705", "000033", "0", "2016/Feb/15 13:10", "Viessmann", "Viessmann", "Vitodens 200-W B2HA-19", "", "", "2013", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "17.5", "17.5", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "65", "4.21", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "97.8", "", "", "", "", "95.9"]} -{"pcdb_id": 17706, "brand_name": "Viessmann", "model_name": "Vitodens 200-W B2HA-26", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 24.1, "final_year_of_manufacture": null, "raw": ["017706", "000033", "0", "2016/Feb/15 13:10", "Viessmann", "Viessmann", "Vitodens 200-W B2HA-26", "", "", "2013", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24.1", "24.1", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "103", "4.21", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "97.8", "", "", "", "", "96.0"]} -{"pcdb_id": 17707, "brand_name": "Viessmann", "model_name": "Vitodens 200-W B2HA-30", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 27.8, "final_year_of_manufacture": null, "raw": ["017707", "000033", "0", "2016/Feb/15 13:10", "Viessmann", "Viessmann", "Vitodens 200-W B2HA-30", "", "", "2013", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "27.8", "27.8", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "106", "4.21", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.2", "97.8", "", "", "", "", "96.0"]} -{"pcdb_id": 17708, "brand_name": "Viessmann", "model_name": "Vitodens 200-W B2HA-35", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 32.2, "final_year_of_manufacture": null, "raw": ["017708", "000033", "0", "2016/Feb/15 13:09", "Viessmann", "Viessmann", "Vitodens 200-W B2HA-35", "", "", "2013", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "32.2", "32.2", "", "", "88.5", "79.5", "", "58.1", "", "2", "", "", "102", "1", "2", "119", "4.21", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "98.0", "", "", "", "", "96.1"]} -{"pcdb_id": 17709, "brand_name": "Viessmann", "model_name": "Vitodens 200-W B2KA-26", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 56.1, "output_kw_max": 24.1, "final_year_of_manufacture": null, "raw": ["017709", "000033", "0", "2016/Feb/15 13:09", "Viessmann", "Viessmann", "Vitodens 200-W B2KA-26", "", "47-819-28", "2013", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.1", "24.1", "", "", "88.4", "79.8", "", "56.1", "", "2", "", "", "104", "1", "2", "116", "4.21", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "97.8", "", "", "", "", "96.0"]} -{"pcdb_id": 17710, "brand_name": "Viessmann", "model_name": "Vitodens 200-W B2KA-30", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 56.2, "output_kw_max": 27.8, "final_year_of_manufacture": null, "raw": ["017710", "000033", "0", "2016/Feb/15 13:09", "Viessmann", "Viessmann", "Vitodens 200-W B2KA-30", "", "47-819-29", "2013", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "27.8", "27.8", "", "", "88.4", "79.8", "", "56.2", "", "2", "", "", "104", "1", "2", "116", "4.21", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.2", "97.8", "", "", "", "", "96.0"]} -{"pcdb_id": 17711, "brand_name": "Viessmann", "model_name": "Vitodens 200-W B2KA-35", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 56.2, "output_kw_max": 32.2, "final_year_of_manufacture": null, "raw": ["017711", "000033", "0", "2016/Feb/15 13:09", "Viessmann", "Viessmann", "Vitodens 200-W B2KA-35", "", "", "2013", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "32.2", "32.2", "", "", "88.5", "79.9", "", "56.2", "", "2", "", "", "104", "1", "2", "126", "4.21", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "98.0", "", "", "", "", "96.1"]} -{"pcdb_id": 17712, "brand_name": "Viessmann", "model_name": "Vitodens 222-F B2TA-19", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 81.1, "comparative_hot_water_efficiency_pct": 52.8, "output_kw_max": 17.2, "final_year_of_manufacture": 2016, "raw": ["017712", "000033", "0", "2024/Jan/31 10:17", "Viessmann", "Viessmann", "Vitodens 222-F B2TA-19", "", "47-819-15", "2013", "2016", "1", "1", "1", "2", "0", "", "", "2", "2", "2", "17.2", "17.2", "", "", "88.4", "81.1", "", "52.8", "", "2", "", "", "106", "1", "2", "156", "4.21", "2", "", "", "100", "0", "50", "2", "60", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "97.8", "", "", "", "", "95.9"]} -{"pcdb_id": 17713, "brand_name": "Viessmann", "model_name": "Vitodens 222-F B2TA-26", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 81.1, "comparative_hot_water_efficiency_pct": 52.9, "output_kw_max": 23.7, "final_year_of_manufacture": 2016, "raw": ["017713", "000033", "0", "2024/Jan/31 10:17", "Viessmann", "Viessmann", "Vitodens 222-F B2TA-26", "", "47-819-16", "2013", "2016", "1", "1", "1", "2", "0", "", "", "2", "2", "2", "23.7", "23.7", "", "", "88.4", "81.1", "", "52.9", "", "2", "", "", "106", "1", "2", "105", "4.21", "2", "", "", "100", "0", "50", "2", "60", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "97.8", "", "", "", "", "96.0"]} -{"pcdb_id": 17714, "brand_name": "Viessmann", "model_name": "Vitodens 222-F B2TA-35", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 81.2, "comparative_hot_water_efficiency_pct": 52.9, "output_kw_max": 31.7, "final_year_of_manufacture": 2016, "raw": ["017714", "000033", "0", "2024/Jan/31 10:17", "Viessmann", "Viessmann", "Vitodens 222-F B2TA-35", "", "47-819-17", "2013", "2016", "1", "1", "1", "2", "0", "", "", "2", "2", "2", "31.7", "31.7", "", "", "88.5", "81.2", "", "52.9", "", "2", "", "", "106", "1", "2", "156", "4.21", "2", "", "", "100", "0", "50", "2", "60", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "98.0", "", "", "", "", "96.1"]} -{"pcdb_id": 17717, "brand_name": "Viessmann", "model_name": "Vitodens 100-W B1HA-19", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 17.3, "final_year_of_manufacture": 2016, "raw": ["017717", "000033", "0", "2016/Mar/09 14:09", "Viessmann", "Viessmann", "Vitodens 100-W B1HA-19", "", "41-819-36", "2014", "2016", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "17.3", "17.3", "", "", "88.5", "79.5", "", "58.1", "", "2", "", "", "102", "1", "2", "84", "4.92", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.2", "97.9", "", "", "", "", "96.1"]} -{"pcdb_id": 17718, "brand_name": "Viessmann", "model_name": "Vitodens 100-W B1HA-26", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 23.7, "final_year_of_manufacture": 2016, "raw": ["017718", "000033", "0", "2016/Mar/09 14:09", "Viessmann", "Viessmann", "Vitodens 100-W B1HA-26", "", "41-819-37", "2014", "2016", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "23.7", "23.7", "", "", "88.5", "79.5", "", "58.0", "", "2", "", "", "102", "1", "2", "92", "4.92", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "97.8", "", "", "", "", "96.0"]} -{"pcdb_id": 17719, "brand_name": "Viessmann", "model_name": "Vitodens 100-W B1HA-30", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 27.3, "final_year_of_manufacture": 2016, "raw": ["017719", "000033", "0", "2016/Mar/09 14:10", "Viessmann", "Viessmann", "Vitodens 100-W B1HA-30", "", "41-819-38", "2014", "2016", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "27.3", "27.3", "", "", "88.3", "79.3", "", "57.9", "", "2", "", "", "102", "1", "2", "98", "4.76", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "97.5", "", "", "", "", "95.7"]} -{"pcdb_id": 17720, "brand_name": "Viessmann", "model_name": "Vitodens 100-W B1HA-35", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 31.9, "final_year_of_manufacture": 2016, "raw": ["017720", "000033", "0", "2016/Mar/09 14:10", "Viessmann", "Viessmann", "Vitodens 100-W B1HA-35", "", "41-819-39", "2014", "2016", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "31.9", "31.9", "", "", "88.5", "79.5", "", "58.1", "", "2", "", "", "102", "1", "2", "108", "4.92", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.2", "98.0", "", "", "", "", "96.2"]} -{"pcdb_id": 17721, "brand_name": "Viessmann", "model_name": "Vitodens 100-W B1KA-26", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 56.2, "output_kw_max": 23.7, "final_year_of_manufacture": 2016, "raw": ["017721", "000033", "0", "2016/Mar/09 14:10", "Viessmann", "Viessmann", "Vitodens 100-W B1KA-26", "", "47-819-33", "2014", "2016", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "23.7", "23.7", "", "", "88.5", "79.9", "", "56.2", "", "2", "", "", "104", "1", "2", "97", "4.92", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "97.8", "", "", "", "", "96.0"]} -{"pcdb_id": 17722, "brand_name": "Viessmann", "model_name": "Vitodens 100-W B1KA-30", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 56.1, "output_kw_max": 27.3, "final_year_of_manufacture": 2016, "raw": ["017722", "000033", "0", "2016/Mar/09 14:10", "Viessmann", "Viessmann", "Vitodens 100-W B1KA-30", "", "47-819-34", "2014", "2016", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "27.3", "27.3", "", "", "88.3", "79.7", "", "56.1", "", "2", "", "", "104", "1", "2", "105", "4.76", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "97.5", "", "", "", "", "95.7"]} -{"pcdb_id": 17723, "brand_name": "Viessmann", "model_name": "Vitodens 100-W B1KA-35", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 56.2, "output_kw_max": 31.9, "final_year_of_manufacture": 2016, "raw": ["017723", "000033", "0", "2016/Mar/09 14:10", "Viessmann", "Viessmann", "Vitodens 100-W B1KA-35", "", "47-819-35", "2014", "2016", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "31.9", "31.9", "", "", "88.5", "79.9", "", "56.2", "", "2", "", "", "104", "1", "2", "119", "4.92", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.2", "98.0", "", "", "", "", "96.2"]} -{"pcdb_id": 17726, "brand_name": "Viessmann", "model_name": "Vitodens 050-W BPJD", "model_qualifier": "29kW Combi Boiler", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 62.3, "output_kw_max": 21.9, "final_year_of_manufacture": null, "raw": ["017726", "000033", "0", "2018/Feb/19 13:43", "Viessmann", "Viessmann", "Vitodens 050-W BPJD", "29kW Combi Boiler", "47-819-38", "2014", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "21.9", "21.9", "", "", "88.4", "79.8", "", "62.3", "", "2", "", "", "104", "1", "2", "97", "2.71", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "", "0035", "", "", "", "", "", "", "", "", "87.8", "98.0", "", "", "", "", "96.1"]} -{"pcdb_id": 17728, "brand_name": "Viessmann", "model_name": "Vitodens 050-W BPJD", "model_qualifier": "35kW Combi Boiler", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 62.3, "output_kw_max": 30.1, "final_year_of_manufacture": null, "raw": ["017728", "000033", "0", "2018/Feb/19 13:42", "Viessmann", "Viessmann", "Vitodens 050-W BPJD", "35kW Combi Boiler", "47-819-39", "2014", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "30.1", "30.1", "", "", "88.4", "79.8", "", "62.3", "", "2", "", "", "104", "1", "2", "141", "2.71", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "", "0035", "", "", "", "", "", "", "", "", "87.8", "97.9", "", "", "", "", "96.0"]} -{"pcdb_id": 17729, "brand_name": "Glow-worm", "model_name": "HOME 25c", "model_qualifier": "", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 77.0, "output_kw_max": 15.2, "final_year_of_manufacture": null, "raw": ["017729", "000207", "0", "2017/Aug/17 12:47", "Glow-worm", "Glow-worm", "HOME 25c", "", "47-019-29", "2015", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "15.2", "15.2", "", "", "88.7", "87.3", "", "77.0", "", "2", "", "", "104", "1", "2", "19", "2", "0", "", "", "", "0", "", "", "", "", "1", "6.835", "0.096", "0.0095", "0.71853", "", "", "", "", "", "1", "1", "", "0085", "", "", "", "", "", "", "", "", "89.7", "97.8", "", "", "", "", "96.2"]} -{"pcdb_id": 17730, "brand_name": "Glow-worm", "model_name": "HOME 30c", "model_qualifier": "", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 75.8, "output_kw_max": 15.2, "final_year_of_manufacture": null, "raw": ["017730", "000207", "0", "2017/Aug/17 12:40", "Glow-worm", "Glow-worm", "HOME 30c", "", "47-019-30", "2015", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "15.2", "15.2", "", "", "88.7", "87.3", "", "75.8", "", "2", "", "", "104", "1", "2", "19", "2", "0", "", "", "", "0", "", "", "", "", "1", "6.945", "0.085", "0.0115", "0.81337", "", "", "", "", "", "1", "1", "", "0085", "", "", "", "", "", "", "", "", "89.7", "97.8", "", "", "", "", "96.2"]} -{"pcdb_id": 17731, "brand_name": "Glow-worm", "model_name": "HOME 35c", "model_qualifier": "", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 76.1, "output_kw_max": 15.2, "final_year_of_manufacture": null, "raw": ["017731", "000207", "0", "2017/Jun/23 12:30", "Glow-worm", "Glow-worm", "HOME 35c", "", "47-019-31", "2015", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "15.2", "15.2", "", "", "88.7", "87.3", "", "76.1", "", "2", "", "", "104", "1", "2", "17", "2", "0", "", "", "", "0", "", "", "", "", "1", "6.921", "0.096", "0.0045", "0.83104", "", "", "", "", "", "1", "1", "", "0085", "", "", "", "", "", "", "", "", "89.7", "97.8", "", "", "", "", "96.2"]} -{"pcdb_id": 17732, "brand_name": "Glow-worm", "model_name": "SUSTAIN 25c", "model_qualifier": "", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 77.0, "output_kw_max": 18.3, "final_year_of_manufacture": null, "raw": ["017732", "000207", "0", "2017/Aug/17 12:47", "Glow-worm", "Glow-worm", "SUSTAIN 25c", "", "47-109-32", "2015", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "18.3", "18.3", "", "", "88.7", "87.3", "", "77.0", "", "2", "", "", "104", "1", "2", "25", "2", "0", "", "", "", "0", "", "", "", "", "1", "6.835", "0.096", "0.0095", "0.71853", "", "", "", "", "", "1", "1", "", "0085", "", "", "", "", "", "", "", "", "89.7", "97.8", "", "", "", "", "96.2"]} -{"pcdb_id": 17733, "brand_name": "Glow-worm", "model_name": "SUSTAIN 30c", "model_qualifier": "", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 75.8, "output_kw_max": 18.3, "final_year_of_manufacture": null, "raw": ["017733", "000207", "0", "2017/Aug/17 12:50", "Glow-worm", "Glow-worm", "SUSTAIN 30c", "", "47-019-33", "2015", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "18.3", "18.3", "", "", "88.7", "87.3", "", "75.8", "", "2", "", "", "104", "1", "2", "21", "2", "0", "", "", "", "0", "", "", "", "", "1", "6.945", "0.085", "0.0115", "0.81337", "", "", "", "", "", "1", "1", "", "0085", "", "", "", "", "", "", "", "", "89.7", "97.8", "", "", "", "", "96.2"]} -{"pcdb_id": 17734, "brand_name": "Glow-worm", "model_name": "SUSTAIN 35c", "model_qualifier": "", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 76.1, "output_kw_max": 18.3, "final_year_of_manufacture": null, "raw": ["017734", "000207", "0", "2017/Jun/23 12:32", "Glow-worm", "Glow-worm", "SUSTAIN 35c", "", "47-019-34", "2015", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "18.3", "18.3", "", "", "88.7", "87.3", "", "76.1", "", "2", "", "", "104", "1", "2", "75", "2", "0", "", "", "", "0", "", "", "", "", "1", "6.921", "0.096", "0.0045", "0.83104", "", "", "", "", "", "1", "1", "", "0085", "", "", "", "", "", "", "", "", "89.7", "97.8", "", "", "", "", "96.2"]} -{"pcdb_id": 17735, "brand_name": "Baxi", "model_name": "Solo 30 Heat IE ErP", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 30.2, "final_year_of_manufacture": null, "raw": ["017735", "000005", "0", "2015/Jul/17 13:45", "Baxi Heating UK", "Baxi", "Solo 30 Heat IE ErP", "", "", "2006", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "30.2", "30.2", "", "", "88.1", "79.1", "", "57.8", "", "2", "", "", "102", "1", "2", "80", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.4", "96.4", "", "", "", "", "95.1"]} -{"pcdb_id": 17736, "brand_name": "Baxi", "model_name": "Solo 24 Heat IE ErP", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 22.0, "final_year_of_manufacture": null, "raw": ["017736", "000005", "0", "2017/Aug/17 12:51", "Baxi Heating UK", "Baxi", "Solo 24 Heat IE ErP", "", "", "2006", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "22", "22", "", "", "88.1", "79.1", "", "57.8", "", "2", "", "", "102", "1", "2", "80", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.5", "96.5", "", "", "", "", "95.2"]} -{"pcdb_id": 17737, "brand_name": "Baxi", "model_name": "Solo 18 Heat IE ErP", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 17.81, "final_year_of_manufacture": null, "raw": ["017737", "000005", "0", "2015/Jul/17 13:44", "Baxi Heating UK", "Baxi", "Solo 18 Heat IE ErP", "", "", "2006", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "17.81", "17.81", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "80", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "96.8", "", "", "", "", "95.2"]} -{"pcdb_id": 17738, "brand_name": "Baxi", "model_name": "Solo 15 Heat IE ErP", "model_qualifier": "", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 15.24, "final_year_of_manufacture": null, "raw": ["017738", "000005", "0", "2015/Jul/17 13:44", "Baxi Heating UK", "Baxi", "Solo 15 Heat IE ErP", "", "", "2006", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "15.24", "15.24", "", "", "88.7", "79.7", "", "58.2", "", "2", "", "", "102", "1", "2", "80", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.3", "97.7", "", "", "", "", "96.3"]} -{"pcdb_id": 17739, "brand_name": "Baxi", "model_name": "Solo 12 Heat IE ErP", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 11.82, "final_year_of_manufacture": null, "raw": ["017739", "000005", "0", "2015/Jul/17 13:44", "Baxi Heating UK", "Baxi", "Solo 12 Heat IE ErP", "", "", "2006", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "11.82", "11.82", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "80", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.6", "96.5", "", "", "", "", "95.0"]} -{"pcdb_id": 17740, "brand_name": "Potterton", "model_name": "Promax 24 Combi ErP", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 73.5, "output_kw_max": 20.0, "final_year_of_manufacture": null, "raw": ["017740", "000005", "0", "2015/Sep/21 14:23", "Baxi Heating UK", "Potterton", "Promax 24 Combi ErP", "", "CG No. 47-393-47", "2008", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "20", "20", "", "", "88.4", "87.3", "", "73.5", "", "2", "", "", "104", "1", "2", "85", "5", "0", "", "", "", "0", "", "", "", "", "1", "7.163", "0.085", "0.0065", "1.06103", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "90.0", "96.9", "", "", "", "", "95.6"]} -{"pcdb_id": 17741, "brand_name": "Potterton", "model_name": "Promax 28 Combi ErP", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 73.4, "output_kw_max": 24.0, "final_year_of_manufacture": null, "raw": ["017741", "000005", "0", "2015/Sep/21 14:23", "Baxi Heating UK", "Potterton", "Promax 28 Combi ErP", "", "GC No. 47-393-48", "2008", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "88.4", "87.3", "", "73.4", "", "2", "", "", "104", "1", "2", "120", "5", "0", "", "", "", "0", "", "", "", "", "1", "7.17", "0.093", "0.0072", "1.06372", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "90.0", "96.9", "", "", "", "", "95.6"]} -{"pcdb_id": 17742, "brand_name": "Potterton", "model_name": "Promax 33 Combi ErP", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 71.1, "output_kw_max": 28.0, "final_year_of_manufacture": null, "raw": ["017742", "000005", "0", "2015/Sep/21 14:23", "Baxi Heating UK", "Potterton", "Promax 33 Combi ErP", "", "GC No. 47-393-49", "2008", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28", "28", "", "", "88.3", "87.3", "", "71.1", "", "2", "", "", "104", "1", "2", "125", "5", "0", "", "", "", "0", "", "", "", "", "1", "7.406", "0.092", "0.0047", "1.30711", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "90.0", "96.7", "", "", "", "", "95.4"]} -{"pcdb_id": 17743, "brand_name": "Potterton", "model_name": "Promax 12 System ErP", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 12.4, "final_year_of_manufacture": null, "raw": ["017743", "000005", "0", "2015/Jul/29 16:46", "Baxi Heating UK", "Potterton", "Promax 12 System ErP", "", "GC No. 41-592-42", "2008", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "12.4", "12.4", "", "", "88.3", "79.3", "", "57.9", "", "2", "", "", "102", "1", "2", "110", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "89.9", "96.7", "", "", "", "", "95.4"]} -{"pcdb_id": 17744, "brand_name": "Potterton", "model_name": "Promax 15 System ErP", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 15.0, "final_year_of_manufacture": null, "raw": ["017744", "000005", "0", "2015/Jul/29 16:46", "Baxi Heating UK", "Potterton", "Promax 15 System ErP", "", "GC No. 41-592-43", "2008", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "15", "15", "", "", "88.3", "79.3", "", "57.9", "", "2", "", "", "102", "1", "2", "95", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "89.9", "96.8", "", "", "", "", "95.5"]} -{"pcdb_id": 17745, "brand_name": "Potterton", "model_name": "Promax 18 System ErP", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 18.0, "final_year_of_manufacture": null, "raw": ["017745", "000005", "0", "2015/Jul/29 16:46", "Baxi Heating UK", "Potterton", "Promax 18 System ErP", "", "GC No. 41-592-44", "2008", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18", "18", "", "", "88.3", "79.3", "", "58.0", "", "2", "", "", "102", "1", "2", "105", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "89.9", "96.9", "", "", "", "", "95.5"]} -{"pcdb_id": 17746, "brand_name": "Potterton", "model_name": "Promax 24 System ErP", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 24.0, "final_year_of_manufacture": null, "raw": ["017746", "000005", "0", "2015/Jul/29 16:50", "Baxi Heating UK", "Potterton", "Promax 24 System ErP", "", "GC No. 41-592-45", "2008", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24", "24", "", "", "88.3", "79.3", "", "58.0", "", "2", "", "", "102", "1", "2", "115", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "89.9", "96.9", "", "", "", "", "95.5"]} -{"pcdb_id": 17747, "brand_name": "Potterton", "model_name": "Promax 32 System ErP", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 32.0, "final_year_of_manufacture": null, "raw": ["017747", "000005", "0", "2015/Jul/29 16:51", "Baxi Heating UK", "Potterton", "Promax 32 System ErP", "", "GC No. 41-592-46", "2008", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "32", "32", "", "", "88.3", "79.3", "", "57.9", "", "2", "", "", "102", "0", "2", "125", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "89.9", "96.7", "", "", "", "", "95.4"]} -{"pcdb_id": 17749, "brand_name": "Glow-worm", "model_name": "HOME 12s", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 12.1, "final_year_of_manufacture": 2016, "raw": ["017749", "000207", "0", "2017/Jun/15 09:27", "Glow-worm", "Glow-worm", "HOME 12s", "", "41-019-27", "2015", "2016", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "12.1", "12.1", "", "", "88.6", "79.6", "", "58.2", "", "2", "", "", "102", "1", "2", "105", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0085", "", "", "", "", "", "", "", "", "89.6", "97.8", "", "", "", "", "96.2"]} -{"pcdb_id": 17750, "brand_name": "Glow-worm", "model_name": "HOME 15s", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 15.2, "final_year_of_manufacture": 2016, "raw": ["017750", "000207", "0", "2017/Jun/15 09:28", "Glow-worm", "Glow-worm", "HOME 15s", "", "41-019-28", "2015", "2016", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "15.2", "15.2", "", "", "88.6", "79.6", "", "58.2", "", "2", "", "", "102", "1", "2", "105", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0085", "", "", "", "", "", "", "", "", "89.6", "97.8", "", "", "", "", "96.2"]} -{"pcdb_id": 17751, "brand_name": "Glow-worm", "model_name": "HOME 18s", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 18.3, "final_year_of_manufacture": 2016, "raw": ["017751", "000207", "0", "2017/Jun/15 09:29", "Glow-worm", "Glow-worm", "HOME 18s", "", "41-019-29", "2015", "2016", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18.3", "18.3", "", "", "88.6", "79.6", "", "58.2", "", "2", "", "", "102", "1", "2", "105", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0085", "", "", "", "", "", "", "", "", "89.6", "97.8", "", "", "", "", "96.2"]} -{"pcdb_id": 17752, "brand_name": "Glow-worm", "model_name": "HOME 25s", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 25.4, "final_year_of_manufacture": 2016, "raw": ["017752", "000207", "0", "2017/Jun/15 09:30", "Glow-worm", "Glow-worm", "HOME 25s", "", "41-019-30", "2015", "2016", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "25.4", "25.4", "", "", "88.6", "79.6", "", "58.2", "", "2", "", "", "102", "1", "2", "110", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0085", "", "", "", "", "", "", "", "", "89.6", "97.8", "", "", "", "", "96.2"]} -{"pcdb_id": 17753, "brand_name": "Glow-worm", "model_name": "SUSTAIN 15s", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 15.2, "final_year_of_manufacture": 2016, "raw": ["017753", "000207", "0", "2017/Jun/15 09:22", "Glow-worm", "Glow-worm", "SUSTAIN 15s", "", "41-019-37", "2015", "2016", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "15.2", "15.2", "", "", "88.6", "79.6", "", "58.2", "", "2", "", "", "102", "1", "2", "65", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0085", "", "", "", "", "", "", "", "", "89.6", "97.8", "", "", "", "", "96.2"]} -{"pcdb_id": 17754, "brand_name": "Glow-worm", "model_name": "SUSTAIN 18s", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 18.3, "final_year_of_manufacture": 2016, "raw": ["017754", "000207", "0", "2017/Jun/15 09:22", "Glow-worm", "Glow-worm", "SUSTAIN 18s", "", "41-019-38", "2015", "2016", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18.3", "18.3", "", "", "88.6", "79.6", "", "58.2", "", "2", "", "", "102", "1", "2", "65", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0085", "", "", "", "", "", "", "", "", "89.6", "97.8", "", "", "", "", "96.2"]} -{"pcdb_id": 17755, "brand_name": "Glow-worm", "model_name": "SUSTAIN 12s", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 12.3, "final_year_of_manufacture": 2016, "raw": ["017755", "000207", "0", "2017/Jun/15 09:20", "Glow-worm", "Glow-worm", "SUSTAIN 12s", "", "41-019-36", "2015", "2016", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "12.3", "12.3", "", "", "88.6", "79.6", "", "58.2", "", "2", "", "", "102", "1", "2", "65", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0085", "", "", "", "", "", "", "", "", "89.6", "97.8", "", "", "", "", "96.2"]} -{"pcdb_id": 17756, "brand_name": "Glow-worm", "model_name": "Easicom 2 24c", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 62.5, "output_kw_max": 20.3, "final_year_of_manufacture": null, "raw": ["017756", "000207", "0", "2015/Sep/21 14:23", "Glow-worm", "Glow-worm", "Easicom 2 24c", "", "47-019-22", "2015", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "20.3", "20.3", "", "", "88.6", "80.0", "", "62.5", "", "2", "", "", "104", "1", "2", "27", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "", "0085", "", "", "", "", "", "", "", "", "89.6", "97.8", "", "", "", "", "96.2"]} -{"pcdb_id": 17757, "brand_name": "Glow-worm", "model_name": "Easicom 2 28c", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 62.5, "output_kw_max": 25.4, "final_year_of_manufacture": null, "raw": ["017757", "000207", "0", "2015/Sep/21 14:23", "Glow-worm", "Glow-worm", "Easicom 2 28c", "", "47-019-23", "2015", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "25.4", "25.4", "", "", "88.6", "80.0", "", "62.5", "", "2", "", "", "104", "1", "2", "29", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "", "0085", "", "", "", "", "", "", "", "", "89.6", "97.8", "", "", "", "", "96.2"]} -{"pcdb_id": 17758, "brand_name": "Glow-worm", "model_name": "Essential 24c", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 62.5, "output_kw_max": 20.3, "final_year_of_manufacture": null, "raw": ["017758", "000207", "0", "2015/Sep/21 14:23", "Glow-worm", "Glow-worm", "Essential 24c", "", "47-019-27", "2015", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "20.3", "20.3", "", "", "88.6", "80.0", "", "62.5", "", "2", "", "", "104", "1", "2", "27", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "", "0085", "", "", "", "", "", "", "", "", "89.6", "97.8", "", "", "", "", "96.2"]} -{"pcdb_id": 17759, "brand_name": "Glow-worm", "model_name": "Essential 28c", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 62.5, "output_kw_max": 24.6, "final_year_of_manufacture": null, "raw": ["017759", "000207", "0", "2015/Sep/21 14:23", "Glow-worm", "Glow-worm", "Essential 28c", "", "47-019-28", "2015", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.6", "24.6", "", "", "88.6", "80.0", "", "62.5", "", "2", "", "", "104", "1", "2", "29", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "", "0085", "", "", "", "", "", "", "", "", "89.6", "97.8", "", "", "", "", "96.2"]} -{"pcdb_id": 17760, "brand_name": "Glow-worm", "model_name": "Energy 25c", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 62.5, "output_kw_max": 18.3, "final_year_of_manufacture": null, "raw": ["017760", "000207", "0", "2015/Sep/21 14:23", "Glow-worm", "Glow-worm", "Energy 25c", "", "47-019-24", "2015", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "18.3", "18.3", "", "", "88.6", "80.0", "", "62.5", "", "2", "", "", "104", "1", "2", "25", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "", "0085", "", "", "", "", "", "", "", "", "89.6", "97.8", "", "", "", "", "96.2"]} -{"pcdb_id": 17761, "brand_name": "Glow-worm", "model_name": "Energy 30c", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 62.5, "output_kw_max": 25.4, "final_year_of_manufacture": null, "raw": ["017761", "000207", "0", "2015/Sep/21 14:23", "Glow-worm", "Glow-worm", "Energy 30c", "", "47-019-25", "2015", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "25.4", "25.4", "", "", "88.6", "80.0", "", "62.5", "", "2", "", "", "104", "1", "2", "75", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "", "0085", "", "", "", "", "", "", "", "", "89.6", "97.8", "", "", "", "", "96.2"]} -{"pcdb_id": 17762, "brand_name": "Glow-worm", "model_name": "Energy 35c", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 62.5, "output_kw_max": 25.6, "final_year_of_manufacture": null, "raw": ["017762", "000207", "0", "2015/Sep/21 14:23", "Glow-worm", "Glow-worm", "Energy 35c", "", "47-019-26", "2015", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "25.6", "25.6", "", "", "88.6", "80.0", "", "62.5", "", "2", "", "", "104", "1", "2", "60", "3", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "", "0085", "", "", "", "", "", "", "", "", "89.6", "97.8", "", "", "", "", "96.2"]} -{"pcdb_id": 17763, "brand_name": "Glow-worm", "model_name": "Energy 35 Store", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 86.8, "comparative_hot_water_efficiency_pct": 59.2, "output_kw_max": 30.0, "final_year_of_manufacture": null, "raw": ["017763", "000207", "0", "2022/May/10 10:35", "Glow-worm", "Glow-worm", "Energy 35 Store", "", "47-019-37", "2015", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "30", "30", "", "", "88.4", "86.8", "", "59.2", "", "2", "", "", "106", "1", "2", "43", "5", "2", "", "", "40", "0", "7", "2", "60", "", "1", "8.89", "0.263", "0.0009", "2.70975", "", "", "", "", "", "", "", "", "0085", "", "", "", "", "", "", "", "", "88.2", "97.8", "", "", "", "", "96.0"]} -{"pcdb_id": 17765, "brand_name": "Glow-worm", "model_name": "HOME 12r", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 12.3, "final_year_of_manufacture": 2016, "raw": ["017765", "000207", "0", "2015/Sep/21 14:23", "Glow-worm", "Glow-worm", "HOME 12r", "", "41-019-31", "2015", "2016", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "12.3", "12.3", "", "", "88.6", "79.6", "", "58.2", "", "2", "", "", "102", "1", "2", "65", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0085", "", "", "", "", "", "", "", "", "89.6", "97.8", "", "", "", "", "96.2"]} -{"pcdb_id": 17766, "brand_name": "Glow-worm", "model_name": "HOME 15r", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 15.2, "final_year_of_manufacture": 2016, "raw": ["017766", "000207", "0", "2017/Jun/15 09:32", "Glow-worm", "Glow-worm", "HOME 15r", "", "41-019-32", "2015", "2016", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "15.2", "15.2", "", "", "88.6", "79.6", "", "58.2", "", "2", "", "", "102", "1", "2", "65", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0085", "", "", "", "", "", "", "", "", "89.6", "97.8", "", "", "", "", "96.2"]} -{"pcdb_id": 17767, "brand_name": "Glow-worm", "model_name": "HOME 18r", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 18.3, "final_year_of_manufacture": 2016, "raw": ["017767", "000207", "0", "2017/Jun/15 09:32", "Glow-worm", "Glow-worm", "HOME 18r", "", "41-019-33", "2015", "2016", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18.3", "18.3", "", "", "88.6", "79.6", "", "58.2", "", "2", "", "", "102", "1", "2", "66", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0085", "", "", "", "", "", "", "", "", "89.6", "97.8", "", "", "", "", "96.2"]} -{"pcdb_id": 17768, "brand_name": "Glow-worm", "model_name": "HOME 25r", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 25.4, "final_year_of_manufacture": 2016, "raw": ["017768", "000207", "0", "2017/Jun/15 09:34", "Glow-worm", "Glow-worm", "HOME 25r", "", "41-019-34", "2015", "2016", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "25.4", "25.4", "", "", "88.6", "79.6", "", "58.2", "", "2", "", "", "102", "1", "2", "75", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0085", "", "", "", "", "", "", "", "", "89.6", "97.8", "", "", "", "", "96.2"]} -{"pcdb_id": 17770, "brand_name": "Glow-worm", "model_name": "SUSTAIN 12r", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 12.3, "final_year_of_manufacture": 2016, "raw": ["017770", "000207", "0", "2017/Jun/15 09:23", "Glow-worm", "Glow-worm", "SUSTAIN 12r", "", "41-019-39", "2015", "2016", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "12.3", "12.3", "", "", "88.6", "79.6", "", "58.2", "", "2", "", "", "102", "1", "2", "65", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0085", "", "", "", "", "", "", "", "", "89.6", "97.8", "", "", "", "", "96.2"]} -{"pcdb_id": 17771, "brand_name": "Glow-worm", "model_name": "SUSTAIN 15r", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 15.2, "final_year_of_manufacture": 2016, "raw": ["017771", "000207", "0", "2017/Jun/15 09:24", "Glow-worm", "Glow-worm", "SUSTAIN 15r", "", "41-019-40", "2015", "2016", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "15.2", "15.2", "", "", "88.6", "79.6", "", "58.2", "", "2", "", "", "102", "1", "2", "65", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0085", "", "", "", "", "", "", "", "", "89.6", "97.8", "", "", "", "", "96.2"]} -{"pcdb_id": 17772, "brand_name": "Glow-worm", "model_name": "SUSTAIN 18r", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 18.3, "final_year_of_manufacture": 2016, "raw": ["017772", "000207", "0", "2017/Jun/15 09:25", "Glow-worm", "Glow-worm", "SUSTAIN 18r", "", "41-019-41", "2015", "2016", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18.3", "18.3", "", "", "88.6", "79.6", "", "58.2", "", "2", "", "", "102", "1", "2", "66", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0085", "", "", "", "", "", "", "", "", "89.6", "97.8", "", "", "", "", "96.2"]} -{"pcdb_id": 17773, "brand_name": "Glow-worm", "model_name": "HOME 30r", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 30.5, "final_year_of_manufacture": 2016, "raw": ["017773", "000207", "0", "2017/Jun/15 09:35", "Glow-worm", "Glow-worm", "HOME 30r", "", "41-019-35", "2015", "2016", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "30.5", "30.5", "", "", "88.5", "79.5", "", "58.1", "", "2", "", "", "102", "1", "2", "60", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0085", "", "", "", "", "", "", "", "", "89.0", "97.8", "", "", "", "", "96.1"]} -{"pcdb_id": 17774, "brand_name": "Glow-worm", "model_name": "ULTIMATE 2 25s", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 25.4, "final_year_of_manufacture": null, "raw": ["017774", "000207", "0", "2015/Sep/21 14:23", "Glow-worm", "Glow-worm", "ULTIMATE 2 25s", "", "47-019-42", "2015", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "25.4", "25.4", "", "", "88.6", "79.6", "", "58.2", "", "2", "", "", "102", "1", "2", "75", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0085", "", "", "", "", "", "", "", "", "89.6", "97.8", "", "", "", "", "96.2"]} -{"pcdb_id": 17775, "brand_name": "Glow-worm", "model_name": "ULTIMATE 2 30C", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 62.5, "output_kw_max": 25.4, "final_year_of_manufacture": null, "raw": ["017775", "000207", "0", "2015/Sep/21 14:23", "Glow-worm", "Glow-worm", "ULTIMATE 2 30C", "", "47-019-35", "2015", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "25.4", "25.4", "", "", "88.6", "80.0", "", "62.5", "", "2", "", "", "104", "1", "2", "110", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "", "0085", "", "", "", "", "", "", "", "", "89.6", "97.8", "", "", "", "", "96.2"]} -{"pcdb_id": 17776, "brand_name": "Glow-worm", "model_name": "ULTIMATE 2 35c", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 62.5, "output_kw_max": 30.4, "final_year_of_manufacture": null, "raw": ["017776", "000207", "0", "2015/Sep/21 14:23", "Glow-worm", "Glow-worm", "ULTIMATE 2 35c", "", "47-019-36", "2015", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "30.4", "30.4", "", "", "88.6", "80.0", "", "62.5", "", "2", "", "", "104", "1", "2", "110", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "", "0085", "", "", "", "", "", "", "", "", "89.6", "97.8", "", "", "", "", "96.2"]} -{"pcdb_id": 17777, "brand_name": "Glow-worm", "model_name": "ENERGY 18r", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 18.3, "final_year_of_manufacture": null, "raw": ["017777", "000207", "0", "2015/Sep/21 14:23", "Glow-worm", "Glow-worm", "ENERGY 18r", "", "41-019-23", "2015", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18.3", "18.3", "", "", "88.6", "79.6", "", "58.2", "", "2", "", "", "102", "1", "2", "66", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0085", "", "", "", "", "", "", "", "", "89.6", "97.8", "", "", "", "", "96.2"]} -{"pcdb_id": 17778, "brand_name": "Glow-worm", "model_name": "ENERGY 25r", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 25.4, "final_year_of_manufacture": null, "raw": ["017778", "000207", "0", "2015/Aug/21 14:21", "Glow-worm", "Glow-worm", "ENERGY 25r", "", "41-019-24", "2015", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "25.4", "25.4", "", "", "88.6", "79.6", "", "58.2", "", "2", "", "", "102", "1", "2", "75", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.6", "97.8", "", "", "", "", "96.2"]} -{"pcdb_id": 17779, "brand_name": "Glow-worm", "model_name": "ENERGY 30r", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 30.5, "final_year_of_manufacture": null, "raw": ["017779", "000207", "0", "2015/Sep/21 14:23", "Glow-worm", "Glow-worm", "ENERGY 30r", "", "41-019-25", "2015", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "30.5", "30.5", "", "", "88.5", "79.5", "", "58.1", "", "2", "", "", "102", "1", "2", "60", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0085", "", "", "", "", "", "", "", "", "89.0", "97.8", "", "", "", "", "96.1"]} -{"pcdb_id": 17781, "brand_name": "Glow-worm", "model_name": "ENERGY 12s", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 12.3, "final_year_of_manufacture": null, "raw": ["017781", "000207", "0", "2015/Sep/21 14:23", "Glow-worm", "Glow-worm", "ENERGY 12s", "", "41-019-16", "2015", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "12.3", "12.3", "", "", "88.6", "79.6", "", "58.2", "", "2", "", "", "102", "1", "2", "65", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0085", "", "", "", "", "", "", "", "", "89.6", "97.8", "", "", "", "", "96.2"]} -{"pcdb_id": 17782, "brand_name": "Glow-worm", "model_name": "ENERGY 15s", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 15.2, "final_year_of_manufacture": null, "raw": ["017782", "000207", "0", "2015/Sep/21 14:23", "Glow-worm", "Glow-worm", "ENERGY 15s", "", "41-019-17", "2015", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "15.2", "15.2", "", "", "88.6", "79.6", "", "58.2", "", "2", "", "", "102", "1", "2", "75", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0085", "", "", "", "", "", "", "", "", "89.6", "97.8", "", "", "", "", "96.2"]} -{"pcdb_id": 17783, "brand_name": "Glow-worm", "model_name": "ENERGY 18s", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 18.3, "final_year_of_manufacture": null, "raw": ["017783", "000207", "0", "2015/Sep/21 14:23", "Glow-worm", "Glow-worm", "ENERGY 18s", "", "41-019-18", "2015", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18.3", "18.3", "", "", "88.6", "79.6", "", "58.2", "", "2", "", "", "102", "1", "2", "66", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0085", "", "", "", "", "", "", "", "", "89.6", "97.8", "", "", "", "", "96.2"]} -{"pcdb_id": 17784, "brand_name": "Glow-worm", "model_name": "ENERGY 25s", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 25.4, "final_year_of_manufacture": null, "raw": ["017784", "000207", "0", "2015/Sep/21 14:23", "Glow-worm", "Glow-worm", "ENERGY 25s", "", "41-019-19", "2015", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "25.4", "25.4", "", "", "88.6", "79.6", "", "58.2", "", "2", "", "", "102", "1", "2", "75", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0085", "", "", "", "", "", "", "", "", "89.6", "97.8", "", "", "", "", "96.2"]} -{"pcdb_id": 17785, "brand_name": "Glow-worm", "model_name": "ENERGY 30s", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 30.5, "final_year_of_manufacture": null, "raw": ["017785", "000207", "0", "2015/Sep/21 14:23", "Glow-worm", "Glow-worm", "ENERGY 30s", "", "41-019-20", "2015", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "30.5", "30.5", "", "", "88.5", "79.5", "", "58.1", "", "2", "", "", "102", "1", "2", "60", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0085", "", "", "", "", "", "", "", "", "89.0", "97.8", "", "", "", "", "96.1"]} -{"pcdb_id": 17789, "brand_name": "Glow-worm", "model_name": "ENERGY 12r", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 12.3, "final_year_of_manufacture": null, "raw": ["017789", "000207", "0", "2015/Sep/21 14:23", "Glow-worm", "Glow-worm", "ENERGY 12r", "", "41-019-21", "2015", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "12.3", "12.3", "", "", "88.6", "79.6", "", "58.2", "", "2", "", "", "102", "1", "2", "65", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0085", "", "", "", "", "", "", "", "", "89.6", "97.8", "", "", "", "", "96.2"]} -{"pcdb_id": 17790, "brand_name": "Glow-worm", "model_name": "ENERGY 15r", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 15.2, "final_year_of_manufacture": null, "raw": ["017790", "000207", "0", "2015/Sep/21 14:23", "Glow-worm", "Glow-worm", "ENERGY 15r", "", "41-019-22", "2015", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "15.2", "15.2", "", "", "88.6", "79.6", "", "58.2", "", "2", "", "", "102", "1", "2", "65", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0085", "", "", "", "", "", "", "", "", "89.6", "97.8", "", "", "", "", "96.2"]} -{"pcdb_id": 17791, "brand_name": "Glow-worm", "model_name": "Ultimate 2 25r", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 25.4, "final_year_of_manufacture": null, "raw": ["017791", "000207", "0", "2015/Aug/21 14:08", "Glow-worm", "Glow-worm", "Ultimate 2 25r", "", "47-019-43", "2015", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "25.4", "25.4", "", "", "88.6", "79.6", "", "58.2", "", "2", "", "", "102", "1", "2", "75", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.6", "97.8", "", "", "", "", "96.2"]} -{"pcdb_id": 17795, "brand_name": "Heatline", "model_name": "CAPRIZ 2 24c", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 62.5, "output_kw_max": 18.3, "final_year_of_manufacture": null, "raw": ["017795", "000031", "0", "2021/Feb/18 14:30", "Vaillant", "Heatline", "CAPRIZ 2 24c", "", "47-157-27", "2015", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "18.3", "18.3", "", "", "88.6", "80.0", "", "62.5", "", "2", "", "", "104", "1", "2", "105", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "", "00010005", "", "", "", "", "", "", "", "", "89.6", "97.8", "", "", "", "", "96.2"]} -{"pcdb_id": 17796, "brand_name": "Heatline", "model_name": "CAPRIZ 2 28c", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 62.5, "output_kw_max": 24.6, "final_year_of_manufacture": null, "raw": ["017796", "000031", "0", "2021/Feb/18 14:38", "Vaillant", "Heatline", "CAPRIZ 2 28c", "", "47-157-28", "2015", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.6", "24.6", "", "", "88.6", "80.0", "", "62.5", "", "2", "", "", "104", "1", "2", "110", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "", "00010005", "", "", "", "", "", "", "", "", "89.6", "97.8", "", "", "", "", "96.2"]} -{"pcdb_id": 17797, "brand_name": "Heatline", "model_name": "MONZA 2 24c", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 62.5, "output_kw_max": 18.3, "final_year_of_manufacture": null, "raw": ["017797", "000031", "0", "2015/Aug/10 11:27", "Vaillant", "Heatline", "MONZA 2 24c", "", "47-157-29", "2015", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "18.3", "18.3", "", "", "88.6", "80.0", "", "62.5", "", "2", "", "", "104", "1", "2", "25", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "", "0005", "", "", "", "", "", "", "", "", "89.6", "97.8", "", "", "", "", "96.2"]} -{"pcdb_id": 17798, "brand_name": "Heatline", "model_name": "MONZA 2 28c", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 62.5, "output_kw_max": 24.6, "final_year_of_manufacture": null, "raw": ["017798", "000031", "0", "2015/Aug/10 11:29", "Vaillant", "Heatline", "MONZA 2 28c", "", "47-157-30", "2015", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.6", "24.6", "", "", "88.6", "80.0", "", "62.5", "", "2", "", "", "104", "1", "2", "29", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "", "0005", "", "", "", "", "", "", "", "", "89.6", "97.8", "", "", "", "", "96.2"]} -{"pcdb_id": 17799, "brand_name": "Potterton", "model_name": "Gold 15 Heat ErP", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 15.24, "final_year_of_manufacture": null, "raw": ["017799", "000005", "0", "2015/Aug/17 12:22", "Baxi Heating UK", "Potterton", "Gold 15 Heat ErP", "", "GC No. 41-592-51", "2006", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "15.24", "15.24", "", "", "88.3", "79.3", "", "57.9", "", "2", "", "", "102", "1", "2", "80", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.3", "96.5", "", "", "", "", "95.3"]} -{"pcdb_id": 17800, "brand_name": "Potterton", "model_name": "Gold 18 Heat ErP", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 17.81, "final_year_of_manufacture": null, "raw": ["017800", "000005", "0", "2015/Aug/17 12:22", "Baxi Heating UK", "Potterton", "Gold 18 Heat ErP", "", "GC No. 41-592-52", "2006", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "17.81", "17.81", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "80", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "96.8", "", "", "", "", "95.2"]} -{"pcdb_id": 17801, "brand_name": "Potterton", "model_name": "Gold 24 Heat ErP", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 22.0, "final_year_of_manufacture": null, "raw": ["017801", "000005", "0", "2015/Aug/17 12:23", "Baxi Heating UK", "Potterton", "Gold 24 Heat ErP", "", "GC No.41-592-53", "2006", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "22", "22", "", "", "88.1", "79.1", "", "57.8", "", "2", "", "", "102", "1", "2", "80", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.5", "96.5", "", "", "", "", "95.2"]} -{"pcdb_id": 17802, "brand_name": "Potterton", "model_name": "Promax SL 12 Heat ErP", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 11.82, "final_year_of_manufacture": null, "raw": ["017802", "000005", "0", "2015/Aug/17 12:24", "Baxi Heating UK", "Potterton", "Promax SL 12 Heat ErP", "", "GC No. 41-592-34", "2006", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "11.82", "11.82", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "80", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.6", "96.5", "", "", "", "", "95.0"]} -{"pcdb_id": 17803, "brand_name": "Potterton", "model_name": "Promax SL 15 Heat ErP", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 15.24, "final_year_of_manufacture": null, "raw": ["017803", "000005", "0", "2015/Aug/17 12:25", "Baxi Heating UK", "Potterton", "Promax SL 15 Heat ErP", "", "GC No. 41-592-35", "2006", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "15.24", "15.24", "", "", "88.3", "79.3", "", "57.9", "", "2", "", "", "102", "1", "2", "80", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.3", "96.5", "", "", "", "", "95.3"]} -{"pcdb_id": 17804, "brand_name": "Potterton", "model_name": "Promax SL 18 Heat ErP", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 17.81, "final_year_of_manufacture": null, "raw": ["017804", "000005", "0", "2015/Aug/17 12:25", "Baxi Heating UK", "Potterton", "Promax SL 18 Heat ErP", "", "GC No. 41-592-36", "2006", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "17.81", "17.81", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "80", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "96.8", "", "", "", "", "95.2"]} -{"pcdb_id": 17805, "brand_name": "Potterton", "model_name": "Promax SL 24 Heat ErP", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 22.0, "final_year_of_manufacture": null, "raw": ["017805", "000005", "0", "2015/Aug/17 12:25", "Baxi Heating UK", "Potterton", "Promax SL 24 Heat ErP", "", "GC No. 41-592-37", "2006", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "22", "22", "", "", "88.1", "79.1", "", "57.8", "", "2", "", "", "102", "1", "2", "80", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.5", "96.5", "", "", "", "", "95.2"]} -{"pcdb_id": 17806, "brand_name": "Potterton", "model_name": "Promax SL 30 Heat ErP", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 30.2, "final_year_of_manufacture": null, "raw": ["017806", "000005", "0", "2015/Aug/17 12:26", "Baxi Heating UK", "Potterton", "Promax SL 30 Heat ErP", "", "GC No. 41-592-38", "2006", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "30.2", "30.2", "", "", "88.1", "79.1", "", "57.8", "", "2", "", "", "102", "1", "2", "80", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.4", "96.4", "", "", "", "", "95.1"]} -{"pcdb_id": 17807, "brand_name": "Main", "model_name": "12 Heat ErP", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 11.8, "final_year_of_manufacture": null, "raw": ["017807", "000005", "0", "2015/Aug/17 11:15", "Baxi Heating UK", "Main", "12 Heat ErP", "", "GC No. 41-467-23", "2006", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "11.8", "11.8", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "80", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.6", "96.5", "", "", "", "", "95.0"]} -{"pcdb_id": 17808, "brand_name": "Main", "model_name": "15 Heat ErP", "model_qualifier": "", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 15.2, "final_year_of_manufacture": null, "raw": ["017808", "000005", "0", "2015/Aug/17 11:16", "Baxi Heating UK", "Main", "15 Heat ErP", "", "GC No. 41-467-24", "2006", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "15.2", "15.2", "", "", "88.7", "79.7", "", "58.2", "", "2", "", "", "102", "1", "2", "80", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.3", "97.7", "", "", "", "", "96.3"]} -{"pcdb_id": 17809, "brand_name": "Main", "model_name": "18 Heat ErP", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 17.8, "final_year_of_manufacture": null, "raw": ["017809", "000005", "0", "2015/Aug/17 11:02", "Baxi Heating UK", "Main", "18 Heat ErP", "", "GC No. 41-467-25", "2006", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "17.8", "17.8", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "80", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "96.8", "", "", "", "", "95.2"]} -{"pcdb_id": 17810, "brand_name": "Main", "model_name": "24 Heat ErP", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 22.0, "final_year_of_manufacture": null, "raw": ["017810", "000005", "0", "2015/Aug/17 11:03", "Baxi Heating UK", "Main", "24 Heat ErP", "", "GC No. 41-467-26", "2006", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "22", "22", "", "", "88.1", "79.1", "", "57.8", "", "2", "", "", "102", "1", "2", "80", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.5", "96.5", "", "", "", "", "95.2"]} -{"pcdb_id": 17811, "brand_name": "Main", "model_name": "30 Heat ErP", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 30.2, "final_year_of_manufacture": null, "raw": ["017811", "000005", "0", "2015/Aug/17 11:16", "Baxi Heating UK", "Main", "30 Heat ErP", "", "GC No.41-467-27", "2006", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "30.2", "30.2", "", "", "88.1", "79.1", "", "57.8", "", "2", "", "", "102", "1", "2", "80", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.4", "96.4", "", "", "", "", "95.1"]} -{"pcdb_id": 17812, "brand_name": "Vaillant", "model_name": "ecoTEC plus 835 H combi A", "model_qualifier": "VUW GB 356/5-5", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 86.9, "comparative_hot_water_efficiency_pct": 71.7, "output_kw_max": 30.4, "final_year_of_manufacture": 2017, "raw": ["017812", "000031", "0", "2019/Mar/04 11:03", "Vaillant Group UK", "Vaillant", "ecoTEC plus 835 H combi A", "VUW GB 356/5-5", "47-044-53", "2015", "2017", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "30.4", "30.4", "", "", "88.7", "86.9", "", "71.7", "", "2", "", "", "104", "1", "2", "90", "2", "0", "", "", "", "0", "", "", "", "", "1", "7.3444", "0.072", "0.0013", "1.23356", "", "", "", "", "", "1", "1", "", "0045", "", "", "", "", "", "", "", "", "88.7", "98.2", "", "", "", "", "96.4"]} -{"pcdb_id": 17813, "brand_name": "Main", "model_name": "Eco Elite 24 System ErP", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 25.9, "final_year_of_manufacture": null, "raw": ["017813", "000005", "0", "2015/Aug/17 11:16", "Baxi Heating UK", "Main", "Eco Elite 24 System ErP", "", "GC No. 41-467-28", "2012", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "25.9", "25.9", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "105", "3.5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.7", "97.0", "", "", "", "", "95.7"]} -{"pcdb_id": 17814, "brand_name": "Main", "model_name": "Eco Elite 28 System ErP", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 28.6, "final_year_of_manufacture": null, "raw": ["017814", "000005", "0", "2015/Aug/17 11:03", "Baxi Heating UK", "Main", "Eco Elite 28 System ErP", "", "GC No. 41-467-29", "2012", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "28.6", "28.6", "", "", "88.1", "79.1", "", "57.8", "", "2", "", "", "102", "1", "2", "105", "3.5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "97.0", "", "", "", "", "95.3"]} -{"pcdb_id": 17815, "brand_name": "Main", "model_name": "Eco Elite 25 Combi ErP", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 56.1, "output_kw_max": 25.9, "final_year_of_manufacture": null, "raw": ["017815", "000005", "0", "2015/Sep/21 14:23", "Baxi Heating UK", "Main", "Eco Elite 25 Combi ErP", "", "GC No. 47-467-12", "2012", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "25.9", "25.9", "", "", "88.4", "79.8", "", "56.1", "", "2", "", "", "104", "1", "2", "105", "3.5", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "89.7", "97.0", "", "", "", "", "95.7"]} -{"pcdb_id": 17816, "brand_name": "Main", "model_name": "Eco Elite 30 Combi ErP", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 55.9, "output_kw_max": 28.6, "final_year_of_manufacture": null, "raw": ["017816", "000005", "0", "2015/Sep/21 14:23", "Baxi Heating UK", "Main", "Eco Elite 30 Combi ErP", "", "GC No. 47-467-13", "2012", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28.6", "28.6", "", "", "88.1", "79.5", "", "55.9", "", "2", "", "", "104", "1", "2", "105", "3.5", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "88.0", "97.0", "", "", "", "", "95.3"]} -{"pcdb_id": 17817, "brand_name": "Potterton", "model_name": "Promax 24 Store ErP", "model_qualifier": "90i Cylinder Assembly", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 52.3, "output_kw_max": 24.0, "final_year_of_manufacture": null, "raw": ["017817", "000005", "0", "2024/Jan/31 10:17", "Baxi Heating UK", "Potterton", "Promax 24 Store ErP", "90i Cylinder Assembly", "GC No.41-592-47", "2006", "current", "1", "1", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "87.9", "80.8", "", "52.3", "", "2", "", "", "106", "1", "2", "126", "3", "2", "2", "", "90", "0", "45", "2", "60", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.2", "96.9", "", "", "", "", "95.0"]} -{"pcdb_id": 17818, "brand_name": "Potterton", "model_name": "Promax 24 Store ErP", "model_qualifier": "115i Cylinder Assembly", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 50.4, "output_kw_max": 24.0, "final_year_of_manufacture": null, "raw": ["017818", "000005", "0", "2024/Jan/31 10:17", "Baxi Heating UK", "Potterton", "Promax 24 Store ErP", "115i Cylinder Assembly", "GC No. 41-592-48", "2006", "current", "1", "1", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "87.9", "80.8", "", "50.4", "", "2", "", "", "106", "1", "2", "126", "3", "2", "2", "", "115", "0", "45", "2", "60", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.2", "96.9", "", "", "", "", "95.0"]} -{"pcdb_id": 17819, "brand_name": "Potterton", "model_name": "Promax 24 Store ErP", "model_qualifier": "150i Cylinder Assembly", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 80.9, "comparative_hot_water_efficiency_pct": 47.0, "output_kw_max": 24.0, "final_year_of_manufacture": null, "raw": ["017819", "000005", "0", "2024/Jan/31 10:17", "Baxi Heating UK", "Potterton", "Promax 24 Store ErP", "150i Cylinder Assembly", "GC No.41-592-49", "2006", "current", "1", "1", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "87.9", "80.9", "", "47.0", "", "2", "", "", "106", "1", "2", "126", "3", "2", "2", "", "150", "0", "45", "2", "60", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.2", "96.9", "", "", "", "", "95.0"]} -{"pcdb_id": 17821, "brand_name": "Vaillant", "model_name": "ecoTEC plus 415", "model_qualifier": "VU 156/6-5", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 15.2, "final_year_of_manufacture": 2017, "raw": ["017821", "000031", "0", "2019/Mar/04 10:03", "Vaillant", "Vaillant", "ecoTEC plus 415", "VU 156/6-5", "41-044-72", "2015", "2017", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "15.2", "15.2", "", "", "88.6", "79.6", "", "58.2", "", "2", "", "", "102", "1", "2", "65", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0045", "", "", "", "", "", "", "", "", "89.6", "97.8", "", "", "", "", "96.2"]} -{"pcdb_id": 17822, "brand_name": "Vaillant", "model_name": "ecoTEC plus 412", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 12.2, "final_year_of_manufacture": 2017, "raw": ["017822", "000031", "0", "2019/Mar/04 10:04", "Vaillant", "Vaillant", "ecoTEC plus 412", "", "41-044-71", "2015", "2017", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "12.2", "12.2", "", "", "88.6", "79.6", "", "58.2", "", "2", "", "", "102", "1", "2", "65", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0045", "", "", "", "", "", "", "", "", "89.6", "97.8", "", "", "", "", "96.2"]} -{"pcdb_id": 17823, "brand_name": "Vaillant", "model_name": "ecoTEC plus 418", "model_qualifier": "VU 186/6-5", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 18.3, "final_year_of_manufacture": 2017, "raw": ["017823", "000031", "0", "2019/Mar/04 10:06", "Vaillant", "Vaillant", "ecoTEC plus 418", "VU 186/6-5", "41-044-73", "2015", "2017", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18.3", "18.3", "", "", "88.6", "79.6", "", "58.2", "", "2", "", "", "102", "1", "2", "66", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0045", "", "", "", "", "", "", "", "", "89.6", "97.8", "", "", "", "", "96.2"]} -{"pcdb_id": 17824, "brand_name": "Vaillant", "model_name": "ecoTEC plus 424", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 24.6, "final_year_of_manufacture": 2019, "raw": ["017824", "000031", "0", "2019/Mar/04 10:06", "Vaillant", "Vaillant", "ecoTEC plus 424", "", "41-044-74", "2015", "2019", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24.6", "24.6", "", "", "88.6", "79.6", "", "58.2", "", "2", "", "", "102", "1", "2", "75", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0045", "", "", "", "", "", "", "", "", "89.6", "97.8", "", "", "", "", "96.2"]} -{"pcdb_id": 17825, "brand_name": "Vaillant", "model_name": "ecoTEC plus 430", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 30.2, "final_year_of_manufacture": 2017, "raw": ["017825", "000031", "0", "2019/Mar/04 10:08", "Vaillant", "Vaillant", "ecoTEC plus 430", "", "41-044-75", "2015", "2017", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "30.2", "30.2", "", "", "88.5", "79.5", "", "58.1", "", "2", "", "", "102", "1", "2", "60", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0045", "", "", "", "", "", "", "", "", "89.0", "97.8", "", "", "", "", "96.1"]} -{"pcdb_id": 17826, "brand_name": "Johnson & Starley", "model_name": "Quantec HR28CP", "model_qualifier": "", "winter_efficiency_pct": 89.7, "summer_efficiency_pct": 88.6, "comparative_hot_water_efficiency_pct": 83.8, "output_kw_max": 21.1, "final_year_of_manufacture": null, "raw": ["017826", "000239", "0", "2015/Dec/24 09:45", "Johnson & Starley", "Johnson & Starley", "Quantec HR28CP", "", "47-416-14", "2015", "current", "2", "2", "1", "2", "1", "", "", "2", "2", "2", "21.1", "21.1", "", "", "89.7", "88.6", "", "83.8", "", "2", "0", "", "104", "1", "2", "68", "2.17", "0", "", "", "", "0", "", "", "", "", "1", "6.422", "0.068", "0.0025", "0.3154", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "", "", "", "", "89.8", "98.3", "", "", "", "", "96.7"]} -{"pcdb_id": 17827, "brand_name": "Vaillant", "model_name": "Home Regular 12", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 12.2, "final_year_of_manufacture": 2018, "raw": ["017827", "000031", "0", "2019/Mar/04 10:46", "Vaillant", "Vaillant", "Home Regular 12", "", "41-044-88", "2015", "2018", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "12.2", "12.2", "", "", "88.6", "79.6", "", "58.2", "", "2", "", "", "102", "1", "2", "65", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0045", "", "", "", "", "", "", "", "", "89.6", "97.8", "", "", "", "", "96.2"]} -{"pcdb_id": 17828, "brand_name": "Vaillant", "model_name": "Home Regular 15", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 15.2, "final_year_of_manufacture": 2018, "raw": ["017828", "000031", "0", "2019/Mar/04 10:48", "Vaillant", "Vaillant", "Home Regular 15", "", "41-44-88", "2015", "2018", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "15.2", "15.2", "", "", "88.6", "79.6", "", "58.2", "", "2", "", "", "102", "1", "2", "65", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0045", "", "", "", "", "", "", "", "", "89.6", "97.8", "", "", "", "", "96.2"]} -{"pcdb_id": 17829, "brand_name": "Vaillant", "model_name": "Home Regular 18", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 18.3, "final_year_of_manufacture": 2018, "raw": ["017829", "000031", "0", "2019/Mar/04 10:48", "Vaillant", "Vaillant", "Home Regular 18", "", "41-44-90", "2015", "2018", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18.3", "18.3", "", "", "88.6", "79.6", "", "58.2", "", "2", "", "", "102", "1", "2", "66", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0045", "", "", "", "", "", "", "", "", "89.6", "97.8", "", "", "", "", "96.2"]} -{"pcdb_id": 17830, "brand_name": "Vaillant", "model_name": "Home Regular 25", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 25.4, "final_year_of_manufacture": 2018, "raw": ["017830", "000031", "0", "2019/Mar/04 10:48", "Vaillant", "Vaillant", "Home Regular 25", "", "41-44-92", "2015", "2018", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "25.4", "25.4", "", "", "88.6", "79.6", "", "58.2", "", "2", "", "", "102", "1", "2", "75", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0045", "", "", "", "", "", "", "", "", "89.6", "97.8", "", "", "", "", "96.2"]} -{"pcdb_id": 17831, "brand_name": "Vaillant", "model_name": "Home Regular 30", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 30.2, "final_year_of_manufacture": 2018, "raw": ["017831", "000031", "0", "2019/Mar/04 10:49", "Vaillant", "Vaillant", "Home Regular 30", "", "41-44-93", "2015", "2018", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "30.2", "30.2", "", "", "88.5", "79.5", "", "58.1", "", "2", "", "", "102", "1", "2", "60", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0045", "", "", "", "", "", "", "", "", "89.0", "97.8", "", "", "", "", "96.1"]} -{"pcdb_id": 17832, "brand_name": "Vaillant", "model_name": "Home System 12", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 12.1, "final_year_of_manufacture": 2018, "raw": ["017832", "000031", "0", "2019/Mar/04 10:49", "Vaillant", "Vaillant", "Home System 12", "", "41-44-94", "2015", "2018", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "12.1", "12.1", "", "", "88.6", "79.6", "", "58.2", "", "2", "", "", "102", "1", "2", "105", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0045", "", "", "", "", "", "", "", "", "89.6", "97.8", "", "", "", "", "96.2"]} -{"pcdb_id": 17833, "brand_name": "Vaillant", "model_name": "Home System 15", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 15.2, "final_year_of_manufacture": 2018, "raw": ["017833", "000031", "0", "2019/Mar/04 10:49", "Vaillant", "Vaillant", "Home System 15", "", "41-44-95", "2015", "2018", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "15.2", "15.2", "", "", "88.6", "79.6", "", "58.2", "", "2", "", "", "102", "1", "2", "105", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0045", "", "", "", "", "", "", "", "", "89.6", "97.8", "", "", "", "", "96.2"]} -{"pcdb_id": 17834, "brand_name": "Vaillant", "model_name": "Home System 18", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 18.3, "final_year_of_manufacture": 2018, "raw": ["017834", "000031", "0", "2019/Mar/04 10:50", "Vaillant", "Vaillant", "Home System 18", "", "41-44-96", "2015", "2018", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18.3", "18.3", "", "", "88.6", "79.6", "", "58.2", "", "2", "", "", "102", "1", "2", "105", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0045", "", "", "", "", "", "", "", "", "89.6", "97.8", "", "", "", "", "96.2"]} -{"pcdb_id": 17835, "brand_name": "Vaillant", "model_name": "Home System 25", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 25.4, "final_year_of_manufacture": 2018, "raw": ["017835", "000031", "0", "2019/Mar/04 10:50", "Vaillant", "Vaillant", "Home System 25", "", "41-44-97", "2015", "2018", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "25.4", "25.4", "", "", "88.6", "79.6", "", "58.2", "", "2", "", "", "102", "1", "2", "110", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0045", "", "", "", "", "", "", "", "", "89.6", "97.8", "", "", "", "", "96.2"]} -{"pcdb_id": 17836, "brand_name": "Vaillant", "model_name": "Home Combi 25", "model_qualifier": "", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 77.0, "output_kw_max": 15.2, "final_year_of_manufacture": 2018, "raw": ["017836", "000031", "0", "2019/Mar/04 10:36", "Vaillant", "Vaillant", "Home Combi 25", "", "", "2015", "2018", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "15.2", "15.2", "", "", "88.7", "87.3", "", "77.0", "", "2", "", "", "104", "1", "2", "105", "2", "0", "", "", "0", "0", "", "", "", "", "1", "6.835", "0.096", "0.0095", "0.71853", "", "", "", "", "", "1", "1", "", "0045", "", "", "", "", "", "", "", "", "89.7", "97.8", "", "", "", "", "96.2"]} -{"pcdb_id": 17837, "brand_name": "Vaillant", "model_name": "Home Combi 30", "model_qualifier": "", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 75.8, "output_kw_max": 15.2, "final_year_of_manufacture": 2018, "raw": ["017837", "000031", "0", "2019/Mar/04 10:36", "Vaillant", "Vaillant", "Home Combi 30", "", "", "2015", "2018", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "15.2", "15.2", "", "", "88.7", "87.3", "", "75.8", "", "2", "", "", "104", "1", "2", "110", "2", "0", "", "", "", "0", "", "", "", "", "1", "6.945", "0.085", "0.0115", "0.81337", "", "", "", "", "", "1", "1", "", "0045", "", "", "", "", "", "", "", "", "89.7", "97.8", "", "", "", "", "96.2"]} -{"pcdb_id": 17838, "brand_name": "Vaillant", "model_name": "Home Combi 35", "model_qualifier": "", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 76.1, "output_kw_max": 15.2, "final_year_of_manufacture": 2018, "raw": ["017838", "000031", "0", "2019/Mar/04 10:37", "Vaillant", "Vaillant", "Home Combi 35", "", "", "2015", "2018", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "15.2", "15.2", "", "", "88.7", "87.3", "", "76.1", "", "2", "", "", "104", "1", "2", "120", "3", "0", "", "", "", "0", "", "", "", "", "1", "6.921", "0.096", "0.0045", "0.83104", "", "", "", "", "", "1", "1", "", "0045", "", "", "", "", "", "", "", "", "89.7", "97.8", "", "", "", "", "96.2"]} -{"pcdb_id": 17839, "brand_name": "ATAG", "model_name": "iC Economiser 27", "model_qualifier": "", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 86.8, "comparative_hot_water_efficiency_pct": 83.2, "output_kw_max": 21.2, "final_year_of_manufacture": null, "raw": ["017839", "000299", "0", "2018/Jan/04 15:44", "ATAG Verwarming Nederland BV", "ATAG", "iC Economiser 27", "", "47-310-27", "2015", "current", "1", "2", "1", "2", "1", "", "", "2", "3", "2", "21.2", "21.2", "", "", "89.1", "86.8", "", "83.2", "", "2", "", "", "104", "1", "2", "184", "4", "0", "", "", "", "0", "", "", "", "", "1", "6.327", "0.181", "0.0012", "0.24179", "11.529", "0.204", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "99.4", "", "", "", "", "97.3"]} -{"pcdb_id": 17840, "brand_name": "ATAG", "model_name": "iC Economiser 35", "model_qualifier": "", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 86.9, "comparative_hot_water_efficiency_pct": 78.7, "output_kw_max": 28.3, "final_year_of_manufacture": 2018, "raw": ["017840", "000299", "0", "2018/Apr/25 14:56", "ATAG Verwarming Nederland BV", "ATAG", "iC Economiser 35", "", "47-310-29", "2015", "2018", "1", "2", "1", "2", "1", "", "", "2", "3", "2", "28.3", "28.3", "", "", "89.1", "86.9", "", "78.7", "", "2", "", "", "104", "1", "2", "112", "5", "0", "", "", "", "0", "", "", "", "", "1", "6.693", "0.172", "0.0", "0.6081", "11.794", "0.192", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.6", "99.5", "", "", "", "", "97.4"]} -{"pcdb_id": 17841, "brand_name": "ATAG", "model_name": "iC Economiser 39", "model_qualifier": "", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 86.9, "comparative_hot_water_efficiency_pct": 78.7, "output_kw_max": 28.3, "final_year_of_manufacture": 2018, "raw": ["017841", "000299", "0", "2018/Apr/25 14:58", "ATAG Verwarming Nederland BV", "ATAG", "iC Economiser 39", "", "47-310-31", "2015", "2018", "1", "2", "1", "2", "1", "", "", "2", "3", "2", "28.3", "28.3", "", "", "89.1", "86.9", "", "78.7", "", "2", "", "", "104", "1", "2", "112", "4", "0", "", "", "", "0", "", "", "", "", "1", "6.693", "0.172", "0.0", "0.6081", "11.794", "0.192", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.6", "99.5", "", "", "", "", "97.4"]} -{"pcdb_id": 17842, "brand_name": "Intergas", "model_name": "Rapid 25", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 56.1, "output_kw_max": 25.1, "final_year_of_manufacture": null, "raw": ["017842", "000256", "0", "2015/Dec/11 11:22", "Intergas Heating Ltd", "Intergas", "Rapid 25", "", "", "2015", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "25.1", "25.1", "", "", "88.4", "79.8", "", "56.1", "", "2", "", "", "104", "1", "2", "80", "1.9", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.1", "97.8", "", "", "", "", "96.0"]} -{"pcdb_id": 17843, "brand_name": "Intergas", "model_name": "Rapid 32", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 56.1, "output_kw_max": 31.9, "final_year_of_manufacture": null, "raw": ["017843", "000256", "0", "2015/Dec/11 11:21", "Intergas Heating Ltd", "Intergas", "Rapid 32", "", "", "2015", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "31.9", "31.9", "", "", "88.3", "79.7", "", "56.1", "", "2", "", "", "104", "1", "2", "80", "1.9", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "97.6", "", "", "", "", "95.8"]} -{"pcdb_id": 17845, "brand_name": "Biasi", "model_name": "Advance Plus 16S ErP", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 15.6, "final_year_of_manufacture": null, "raw": ["017845", "000208", "0", "2015/Dec/14 09:52", "Biasi (UK)", "Biasi", "Advance Plus 16S ErP", "", "41-583-27", "2015", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "15.6", "15.6", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "78", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "96.8", "", "", "", "", "95.1"]} -{"pcdb_id": 17846, "brand_name": "Biasi", "model_name": "Advance Plus 25S ErP", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 24.4, "final_year_of_manufacture": null, "raw": ["017846", "000208", "0", "2015/Dec/11 09:27", "Biasi (UK)", "Biasi", "Advance Plus 25S ErP", "", "41-583-28", "2015", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24.4", "24.4", "", "", "88.1", "79.1", "", "57.7", "", "2", "", "", "102", "1", "2", "95", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "97.0", "", "", "", "", "95.3"]} -{"pcdb_id": 17847, "brand_name": "Biasi", "model_name": "Advance Plus 30S ErP", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 29.5, "final_year_of_manufacture": null, "raw": ["017847", "000208", "0", "2015/Dec/11 09:27", "Biasi (UK)", "Biasi", "Advance Plus 30S ErP", "", "41-583-29", "2015", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "29.5", "29.5", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "104", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.5", "96.7", "", "", "", "", "95.1"]} -{"pcdb_id": 17848, "brand_name": "Biasi", "model_name": "Advance Plus 25C ErP", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 86.6, "comparative_hot_water_efficiency_pct": 74.1, "output_kw_max": 19.5, "final_year_of_manufacture": null, "raw": ["017848", "000208", "0", "2015/Dec/11 09:28", "Biasi (UK)", "Biasi", "Advance Plus 25C ErP", "", "47-583-35", "2015", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "19.5", "19.5", "", "", "88.1", "86.6", "", "74.1", "", "2", "", "", "104", "1", "2", "86", "5", "0", "", "", "", "0", "", "", "", "", "1", "7.11", "0.149", "0.0", "0.98922", "", "", "", "", "", "1", "0", "", "0005", "", "", "", "", "", "", "", "", "87.8", "97.0", "", "", "", "", "95.3"]} -{"pcdb_id": 17849, "brand_name": "Biasi", "model_name": "Advance Plus 30C ErP", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 86.8, "comparative_hot_water_efficiency_pct": 74.1, "output_kw_max": 24.4, "final_year_of_manufacture": null, "raw": ["017849", "000208", "0", "2015/Dec/11 09:28", "Biasi (UK)", "Biasi", "Advance Plus 30C ErP", "", "47-583-36", "2015", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.4", "24.4", "", "", "88.0", "86.8", "", "74.1", "", "2", "", "", "104", "1", "2", "95", "5", "0", "", "", "", "0", "", "", "", "", "1", "7.104", "0.163", "0.002", "0.98571", "", "", "", "", "", "1", "0", "", "0005", "", "", "", "", "", "", "", "", "88.3", "96.7", "", "", "", "", "95.1"]} -{"pcdb_id": 17851, "brand_name": "Biasi", "model_name": "Advance Plus 35C ErP", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 86.8, "comparative_hot_water_efficiency_pct": 74.0, "output_kw_max": 29.5, "final_year_of_manufacture": null, "raw": ["017851", "000208", "0", "2015/Dec/11 09:29", "Biasi (UK)", "Biasi", "Advance Plus 35C ErP", "", "47-583-37", "2015", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "29.5", "29.5", "", "", "88.0", "86.8", "", "74.0", "", "2", "", "", "104", "1", "2", "104", "5", "0", "", "", "", "0", "", "", "", "", "1", "7.12", "0.152", "0.002", "1.00577", "", "", "", "", "", "1", "0", "", "0005", "", "", "", "", "", "", "", "", "88.5", "96.7", "", "", "", "", "95.1"]} -{"pcdb_id": 17852, "brand_name": "Biasi", "model_name": "Inovia 25S ErP", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 24.4, "final_year_of_manufacture": null, "raw": ["017852", "000208", "0", "2015/Dec/11 09:29", "Biasi (UK)", "Biasi", "Inovia 25S ErP", "", "41-583-30", "2015", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24.4", "24.4", "", "", "88.1", "79.1", "", "57.7", "", "2", "", "", "102", "1", "2", "95", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "97.0", "", "", "", "", "95.3"]} -{"pcdb_id": 17853, "brand_name": "Biasi", "model_name": "Inovia 25C ErP", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 86.6, "comparative_hot_water_efficiency_pct": 74.1, "output_kw_max": 19.5, "final_year_of_manufacture": null, "raw": ["017853", "000208", "0", "2015/Dec/11 09:30", "Biasi (UK)", "Biasi", "Inovia 25C ErP", "", "47-583-38", "2015", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "19.5", "19.5", "", "", "88.1", "86.6", "", "74.1", "", "2", "", "", "104", "1", "2", "86", "5", "0", "", "", "", "0", "", "", "", "", "1", "7.11", "0.149", "0.0", "0.98922", "", "", "", "", "", "1", "1", "", "0005", "", "", "", "", "", "", "", "", "87.8", "97.0", "", "", "", "", "95.3"]} -{"pcdb_id": 17854, "brand_name": "Biasi", "model_name": "Inovia 30C ErP", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 86.8, "comparative_hot_water_efficiency_pct": 74.1, "output_kw_max": 24.4, "final_year_of_manufacture": null, "raw": ["017854", "000208", "0", "2015/Dec/11 09:30", "Biasi (UK)", "Biasi", "Inovia 30C ErP", "", "47-583-39", "2015", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.4", "24.4", "", "", "88.0", "86.8", "", "74.1", "", "2", "", "", "104", "1", "2", "95", "5", "0", "", "", "", "0", "", "", "", "", "1", "7.104", "0.163", "0.002", "0.98571", "", "", "", "", "", "1", "1", "", "0005", "", "", "", "", "", "", "", "", "88.3", "96.7", "", "", "", "", "95.1"]} -{"pcdb_id": 17855, "brand_name": "Biasi", "model_name": "Inovia 35C ErP", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 86.8, "comparative_hot_water_efficiency_pct": 74.0, "output_kw_max": 29.5, "final_year_of_manufacture": null, "raw": ["017855", "000208", "0", "2015/Dec/11 09:30", "Biasi (UK)", "Biasi", "Inovia 35C ErP", "", "47-583-40", "2015", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "29.5", "29.5", "", "", "88.0", "86.8", "", "74.0", "", "2", "", "", "104", "1", "2", "104", "5", "0", "", "", "", "0", "", "", "", "", "1", "7.12", "0.152", "0.002", "1.00577", "", "", "", "", "", "1", "1", "", "0005", "", "", "", "", "", "", "", "", "88.5", "96.7", "", "", "", "", "95.1"]} -{"pcdb_id": 17856, "brand_name": "Biasi", "model_name": "Riva Plus HE 24C ErP", "model_qualifier": "", "winter_efficiency_pct": 87.4, "summer_efficiency_pct": 86.6, "comparative_hot_water_efficiency_pct": 67.4, "output_kw_max": 24.4, "final_year_of_manufacture": null, "raw": ["017856", "000208", "0", "2015/Dec/11 09:30", "Biasi (UK)", "Biasi", "Riva Plus HE 24C ErP", "", "47-583-41", "2015", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.4", "24.4", "", "", "87.4", "86.6", "", "67.4", "", "2", "", "", "104", "1", "2", "79", "3", "0", "", "", "", "0", "", "", "", "", "1", "7.816", "0.131", "0.005", "1.63862", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "95.4", "", "", "", "", "94.0"]} -{"pcdb_id": 17857, "brand_name": "Biasi", "model_name": "Riva Plus HE 28C ErP", "model_qualifier": "", "winter_efficiency_pct": 87.4, "summer_efficiency_pct": 86.7, "comparative_hot_water_efficiency_pct": 68.0, "output_kw_max": 28.3, "final_year_of_manufacture": null, "raw": ["017857", "000208", "0", "2015/Dec/11 09:31", "Biasi (UK)", "Biasi", "Riva Plus HE 28C ErP", "", "47-583-42", "2015", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28.3", "28.3", "", "", "87.4", "86.7", "", "68.0", "", "2", "", "", "104", "1", "2", "90", "3", "0", "", "", "", "0", "", "", "", "", "1", "7.75", "0.137", "0.013", "1.53602", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "95.2", "", "", "", "", "93.9"]} -{"pcdb_id": 17858, "brand_name": "Biasi", "model_name": "Riva Plus HE 24S ErP", "model_qualifier": "", "winter_efficiency_pct": 87.4, "summer_efficiency_pct": 78.4, "comparative_hot_water_efficiency_pct": 57.3, "output_kw_max": 24.4, "final_year_of_manufacture": null, "raw": ["017858", "000208", "0", "2015/Dec/11 09:31", "Biasi (UK)", "Biasi", "Riva Plus HE 24S ErP", "", "41-583-31", "2015", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24.4", "24.4", "", "", "87.4", "78.4", "", "57.3", "", "2", "", "", "102", "1", "2", "79", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "95.4", "", "", "", "", "94.0"]} -{"pcdb_id": 17859, "brand_name": "Biasi", "model_name": "Riva Plus HE 28S ErP", "model_qualifier": "", "winter_efficiency_pct": 87.4, "summer_efficiency_pct": 78.4, "comparative_hot_water_efficiency_pct": 57.3, "output_kw_max": 28.3, "final_year_of_manufacture": null, "raw": ["017859", "000208", "0", "2015/Dec/11 09:31", "Biasi (UK)", "Biasi", "Riva Plus HE 28S ErP", "", "41-583-32", "2015", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "28.3", "28.3", "", "", "87.4", "78.4", "", "57.3", "", "2", "", "", "102", "1", "2", "90", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "95.2", "", "", "", "", "93.9"]} -{"pcdb_id": 17861, "brand_name": "Ideal", "model_name": "LOGIC COMBI", "model_qualifier": "ESP24", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 76.9, "output_kw_max": 24.2, "final_year_of_manufacture": 2016, "raw": ["017861", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "LOGIC COMBI", "ESP24", "47-349-12", "2016", "2016", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "88.4", "87.3", "", "76.9", "", "2", "", "", "104", "1", "2", "42", "0.5", "0", "", "", "", "0", "", "", "", "", "1", "6.848", "0.096", "0.0005", "0.78594", "", "", "", "", "", "0", "", "", "0035", "", "", "", "", "", "", "", "", "89.8", "96.9", "", "", "", "", "95.6"]} -{"pcdb_id": 17862, "brand_name": "Ideal", "model_name": "LOGIC COMBI", "model_qualifier": "ESP30", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 79.4, "output_kw_max": 24.2, "final_year_of_manufacture": 2016, "raw": ["017862", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "LOGIC COMBI", "ESP30", "47-349-13", "2016", "2016", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "88.4", "87.3", "", "79.4", "", "2", "", "", "104", "1", "2", "32", "5", "0", "", "", "", "0", "", "", "", "", "1", "6.632", "0.094", "0.0005", "0.58118", "", "", "", "", "", "0", "", "", "0035", "", "", "", "", "", "", "", "", "90.0", "96.9", "", "", "", "", "95.6"]} -{"pcdb_id": 17863, "brand_name": "Ideal", "model_name": "LOGIC COMBI", "model_qualifier": "ESP35", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 79.0, "output_kw_max": 24.2, "final_year_of_manufacture": 2016, "raw": ["017863", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "LOGIC COMBI", "ESP35", "47-349-14", "2016", "2016", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "88.3", "87.3", "", "79.0", "", "2", "", "", "104", "1", "2", "29", "5", "0", "", "", "", "0", "", "", "", "", "1", "6.669", "0.094", "0.0006", "0.61175", "", "", "", "", "", "0", "", "", "0035", "", "", "", "", "", "", "", "", "89.8", "96.9", "", "", "", "", "95.5"]} -{"pcdb_id": 17867, "brand_name": "Sime", "model_name": "Murelle HE", "model_qualifier": "50 R ErP", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 46.8, "final_year_of_manufacture": 2018, "raw": ["017867", "000213", "0", "2018/Mar/07 10:10", "Fonderie Sime S.p.A.", "Sime", "Murelle HE", "50 R ErP", "41-283-60", "2015", "2018", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "46.8", "46.8", "", "", "88.8", "79.8", "", "58.3", "", "2", "1", "", "102", "1", "2", "96", "4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.8", "98.5", "", "", "", "", "96.9"]} -{"pcdb_id": 17868, "brand_name": "Sime", "model_name": "Murelle HE", "model_qualifier": "50 R ErP", "winter_efficiency_pct": 87.8, "summer_efficiency_pct": 78.8, "comparative_hot_water_efficiency_pct": 57.6, "output_kw_max": 46.8, "final_year_of_manufacture": 2018, "raw": ["017868", "000213", "0", "2018/Mar/07 09:48", "Fonderie Sime S.p.A.", "Sime", "Murelle HE", "50 R ErP", "41-283-60", "2015", "2018", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "46.8", "46.8", "", "", "87.8", "78.8", "", "57.6", "", "2", "", "", "102", "1", "2", "96", "4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "96.4", "", "", "", "", "94.8"]} -{"pcdb_id": 17869, "brand_name": "Sime", "model_name": "Murelle HE", "model_qualifier": "35 R ErP", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 33.8, "final_year_of_manufacture": 2018, "raw": ["017869", "000213", "0", "2018/Mar/05 16:57", "Fonderie Sime S.p.A.", "Sime", "Murelle HE", "35 R ErP", "41-283-59", "2015", "2018", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "33.8", "33.8", "", "", "88.8", "79.8", "", "58.3", "", "2", "1", "", "102", "1", "2", "64", "4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.5", "98.5", "", "", "", "", "96.8"]} -{"pcdb_id": 17870, "brand_name": "Sime", "model_name": "Murelle HE", "model_qualifier": "35 R ErP", "winter_efficiency_pct": 87.8, "summer_efficiency_pct": 78.8, "comparative_hot_water_efficiency_pct": 57.5, "output_kw_max": 33.8, "final_year_of_manufacture": 2018, "raw": ["017870", "000213", "0", "2018/Mar/05 16:57", "Fonderie Sime S.p.A.", "Sime", "Murelle HE", "35 R ErP", "41-283-59", "2015", "2018", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "33.8", "33.8", "", "", "87.8", "78.8", "", "57.5", "", "2", "", "", "102", "1", "2", "64", "4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.6", "96.4", "", "", "", "", "94.7"]} -{"pcdb_id": 17873, "brand_name": "Grant", "model_name": "VortexBlue Internal 21kW", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 80.7, "comparative_hot_water_efficiency_pct": 58.9, "output_kw_max": 21.0, "final_year_of_manufacture": null, "raw": ["017873", "000048", "0", "2020/Jan/15 12:18", "Grant Engineering", "Grant", "VortexBlue Internal 21kW", "", "", "2017", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "15", "21", "", "", "88.5", "80.7", "", "58.9", "", "2", "", "", "201", "1", "1", "143", "1", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.4", "95.8", "", "", "", "", "94.9"]} -{"pcdb_id": 17874, "brand_name": "Grant", "model_name": "VortexBlue Internal 26kW", "model_qualifier": "", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 80.9, "comparative_hot_water_efficiency_pct": 59.1, "output_kw_max": 26.0, "final_year_of_manufacture": null, "raw": ["017874", "000048", "0", "2020/Apr/15 08:57", "Grant Engineering", "Grant", "VortexBlue Internal 26kW", "", "", "2017", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "26", "26", "", "", "88.7", "80.9", "", "59.1", "", "2", "", "", "201", "1", "1", "147", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "92.7", "95.9", "", "", "", "", "95.2"]} -{"pcdb_id": 17875, "brand_name": "Grant", "model_name": "VortexBlue Internal Sealed System 21kW", "model_qualifier": "", "winter_efficiency_pct": 87.7, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 21.0, "final_year_of_manufacture": null, "raw": ["017875", "000048", "0", "2020/Jan/15 12:19", "Grant Engineering", "Grant", "VortexBlue Internal Sealed System 21kW", "", "", "2017", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "15", "21", "", "", "87.7", "79.9", "", "58.4", "", "2", "", "", "201", "1", "1", "143", "1", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "88.5", "95.8", "", "", "", "", "94.4"]} -{"pcdb_id": 17876, "brand_name": "Grant", "model_name": "VortexBlue Internal Sealed System 26kW", "model_qualifier": "", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 80.9, "comparative_hot_water_efficiency_pct": 59.1, "output_kw_max": 26.0, "final_year_of_manufacture": null, "raw": ["017876", "000048", "0", "2020/Apr/15 08:57", "Grant Engineering", "Grant", "VortexBlue Internal Sealed System 26kW", "", "", "2017", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "26", "26", "", "", "88.7", "80.9", "", "59.1", "", "2", "", "", "201", "1", "1", "147", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "92.7", "95.9", "", "", "", "", "95.2"]} -{"pcdb_id": 17877, "brand_name": "Grant", "model_name": "VortexBlue Internal Sealed System 36kW", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 59.0, "output_kw_max": 36.0, "final_year_of_manufacture": null, "raw": ["017877", "000048", "0", "2020/Jan/15 12:19", "Grant Engineering", "Grant", "VortexBlue Internal Sealed System 36kW", "", "", "2017", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "26", "36", "", "", "88.6", "80.8", "", "59.0", "", "2", "", "", "201", "1", "1", "150", "1", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.1", "96.1", "", "", "", "", "95.2"]} -{"pcdb_id": 17878, "brand_name": "Grant", "model_name": "VortexBlue External 21kW", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 80.7, "comparative_hot_water_efficiency_pct": 58.9, "output_kw_max": 21.0, "final_year_of_manufacture": null, "raw": ["017878", "000048", "0", "2020/Jan/15 12:20", "Grant Engineering", "Grant", "VortexBlue External 21kW", "", "", "2017", "current", "4", "1", "2", "1", "0", "", "", "2", "3", "2", "15", "21", "", "", "88.5", "80.7", "", "58.9", "", "2", "", "", "201", "1", "1", "143", "1", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.4", "95.8", "", "", "", "", "94.9"]} -{"pcdb_id": 17879, "brand_name": "Grant", "model_name": "VortexBlue External 26kW", "model_qualifier": "", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 80.9, "comparative_hot_water_efficiency_pct": 59.1, "output_kw_max": 26.0, "final_year_of_manufacture": null, "raw": ["017879", "000048", "0", "2020/Apr/15 08:58", "Grant Engineering", "Grant", "VortexBlue External 26kW", "", "", "2017", "current", "4", "1", "2", "1", "0", "", "", "2", "3", "2", "26", "26", "", "", "88.7", "80.9", "", "59.1", "", "2", "", "", "201", "1", "1", "147", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "92.7", "95.9", "", "", "", "", "95.2"]} -{"pcdb_id": 17880, "brand_name": "Grant", "model_name": "VortexBlue External 36kW", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 59.0, "output_kw_max": 36.0, "final_year_of_manufacture": null, "raw": ["017880", "000048", "0", "2020/Jan/15 12:20", "Grant Engineering", "Grant", "VortexBlue External 36kW", "", "", "2017", "current", "4", "1", "2", "1", "0", "", "", "2", "3", "2", "26", "36", "", "", "88.6", "80.8", "", "59.0", "", "2", "", "", "201", "1", "1", "150", "1", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.1", "96.1", "", "", "", "", "95.2"]} -{"pcdb_id": 17887, "brand_name": "Grant", "model_name": "Vortex PRO Combi XS 26", "model_qualifier": "", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 82.8, "comparative_hot_water_efficiency_pct": 45.3, "output_kw_max": 26.0, "final_year_of_manufacture": null, "raw": ["017887", "000048", "0", "2024/Jan/31 10:17", "Grant Engineering", "Grant", "Vortex PRO Combi XS 26", "", "", "2016", "current", "4", "1", "1", "2", "0", "", "", "2", "3", "2", "26", "26", "", "", "88.9", "82.8", "", "45.3", "", "2", "", "", "203", "1", "1", "", "", "1", "", "", "40", "0", "25", "3", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "92.5", "96.4", "", "", "", "", "95.7"]} -{"pcdb_id": 17888, "brand_name": "Grant", "model_name": "VortexBlue Internal 36kW", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 59.0, "output_kw_max": 36.0, "final_year_of_manufacture": null, "raw": ["017888", "000048", "0", "2020/Jan/15 12:19", "Grant Engineering", "Grant", "VortexBlue Internal 36kW", "", "", "2017", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "26", "36", "", "", "88.6", "80.8", "", "59.0", "", "2", "", "", "201", "1", "1", "150", "1", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.1", "96.1", "", "", "", "", "95.2"]} -{"pcdb_id": 17889, "brand_name": "Daikin", "model_name": "EHYKOMB33AA", "model_qualifier": "EHYKOMB33AAS", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 26.6, "final_year_of_manufacture": null, "raw": ["017889", "000278", "0", "2016/Apr/11 16:37", "Daikin Europe NV", "Daikin", "EHYKOMB33AA", "EHYKOMB33AAS", "47-464-01", "2013", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "26.6", "26.6", "", "", "88.5", "79.5", "", "58.0", "", "2", "", "", "102", "1", "2", "55", "1.9", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.9", "97.6", "", "", "", "", "95.9"]} -{"pcdb_id": 17891, "brand_name": "Vokera", "model_name": "Excel", "model_qualifier": "25", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 56.1, "output_kw_max": 19.5, "final_year_of_manufacture": null, "raw": ["017891", "000011", "0", "2016/Oct/24 11:40", "Vokera", "Vokera", "Excel", "25", "47 364 12", "2013", "current", "2", "2", "1", "2", "0", "", "", "2", "3", "2", "19.5", "19.5", "", "", "88.3", "79.7", "", "56.1", "", "2", "1", "", "104", "1", "2", "29", "6", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.9", "97.3", "", "", "", "", "95.9"]} -{"pcdb_id": 17892, "brand_name": "Vokera", "model_name": "Excel", "model_qualifier": "29", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 56.3, "output_kw_max": 24.45, "final_year_of_manufacture": null, "raw": ["017892", "000011", "0", "2016/Oct/24 11:41", "Vokera", "Vokera", "Excel", "29", "47 364 13", "2013", "current", "2", "2", "1", "2", "0", "", "", "2", "3", "2", "24.45", "24.45", "", "", "88.6", "80.0", "", "56.3", "", "2", "1", "", "104", "1", "2", "38", "6", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.1", "98.0", "", "", "", "", "96.5"]} -{"pcdb_id": 17893, "brand_name": "Vokera", "model_name": "Vibe", "model_qualifier": "20A", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 19.5, "final_year_of_manufacture": null, "raw": ["017893", "000011", "0", "2016/Oct/24 11:41", "Vokera", "Vokera", "Vibe", "20A", "41 094 84", "2014", "current", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "19.50", "19.50", "", "", "88.3", "79.3", "", "57.9", "", "2", "1", "", "102", "1", "2", "29", "6", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.9", "97.3", "", "", "", "", "95.9"]} -{"pcdb_id": 17894, "brand_name": "Vokera", "model_name": "Vibe", "model_qualifier": "25A", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 24.45, "final_year_of_manufacture": null, "raw": ["017894", "000011", "0", "2016/Oct/24 11:41", "Vokera", "Vokera", "Vibe", "25A", "41 094 85", "2014", "current", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "24.45", "24.45", "", "", "88.6", "79.6", "", "58.2", "", "2", "1", "", "102", "1", "2", "38", "6", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.1", "98.0", "", "", "", "", "96.5"]} -{"pcdb_id": 17895, "brand_name": "Vokera", "model_name": "Compact", "model_qualifier": "25A", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 56.1, "output_kw_max": 19.5, "final_year_of_manufacture": null, "raw": ["017895", "000011", "0", "2016/Oct/24 11:41", "Vokera", "Vokera", "Compact", "25A", "47 364 17", "2013", "current", "2", "2", "1", "2", "0", "", "", "2", "3", "2", "19.50", "19.50", "", "", "88.3", "79.7", "", "56.1", "", "2", "1", "", "104", "1", "2", "29", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.9", "97.3", "", "", "", "", "95.9"]} -{"pcdb_id": 17896, "brand_name": "Vokera", "model_name": "Compact", "model_qualifier": "29A", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 56.3, "output_kw_max": 24.45, "final_year_of_manufacture": null, "raw": ["017896", "000011", "0", "2016/Oct/24 11:41", "Vokera", "Vokera", "Compact", "29A", "47 364 18", "2013", "current", "2", "2", "1", "2", "0", "", "", "2", "3", "2", "24.45", "24.45", "", "", "88.6", "80.0", "", "56.3", "", "2", "1", "", "104", "1", "2", "38", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.1", "98.0", "", "", "", "", "96.5"]} -{"pcdb_id": 17899, "brand_name": "Ferroli", "model_name": "MODENA 38C HE", "model_qualifier": "47-267-63", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 86.8, "comparative_hot_water_efficiency_pct": 68.3, "output_kw_max": 34.3, "final_year_of_manufacture": null, "raw": ["017899", "000097", "0", "2016/Apr/20 10:18", "Ferroli", "Ferroli", "MODENA 38C HE", "47-267-63", "", "2015", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "34.3", "34.3", "", "", "88.5", "86.8", "", "68.3", "", "2", "", "", "104", "1", "2", "110", "3", "0", "", "", "", "0", "", "", "", "", "1", "7.715", "0.0589", "0.005", "1.55696", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "98.0", "", "", "", "", "96.2"]} -{"pcdb_id": 17900, "brand_name": "Ferroli", "model_name": "FERcondens", "model_qualifier": "25 HE", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 86.6, "comparative_hot_water_efficiency_pct": 56.9, "output_kw_max": 24.4, "final_year_of_manufacture": 2015, "raw": ["017900", "000097", "0", "2016/Apr/25 16:47", "Ferroli", "Ferroli", "FERcondens", "25 HE", "", "2013", "2015", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.4", "24.4", "", "", "87.9", "86.6", "", "56.9", "", "2", "", "", "104", "1", "2", "58", "3", "0", "", "", "", "0", "", "", "", "", "1", "9.26", "0.07469", "0.0036", "3.03782", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "96.5", "", "", "", "", "94.9"]} -{"pcdb_id": 17902, "brand_name": "Worcester", "model_name": "GB162-50 V2", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 46.6, "final_year_of_manufacture": null, "raw": ["017902", "000035", "0", "2016/May/18 11:07", "Worcester Bosch Group", "Worcester", "GB162-50 V2", "", "", "2016", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "46.6", "46.6", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "41", "6", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.5", "97.0", "", "", "", "", "95.2"]} -{"pcdb_id": 17903, "brand_name": "Worcester", "model_name": "GB162-65 V2", "model_qualifier": "", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 78.9, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 62.9, "final_year_of_manufacture": null, "raw": ["017903", "000035", "0", "2016/May/18 11:08", "Worcester Bosch Group", "Worcester", "GB162-65 V2", "", "", "2016", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "62.9", "62.9", "", "", "87.9", "78.9", "", "57.7", "", "2", "", "", "102", "1", "2", "82", "6", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.3", "96.9", "", "", "", "", "95.1"]} -{"pcdb_id": 17904, "brand_name": "Vokera", "model_name": "Easi-Heat Plus 25C", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 56.2, "output_kw_max": 19.5, "final_year_of_manufacture": null, "raw": ["017904", "000011", "0", "2016/Jun/01 09:15", "Vokera", "Vokera", "Easi-Heat Plus 25C", "", "47-364-29", "2016", "current", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "19.5", "19.5", "", "", "88.5", "79.9", "", "56.2", "", "2", "", "", "104", "1", "2", "29", "6", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "98.1", "", "", "", "", "96.2"]} -{"pcdb_id": 17905, "brand_name": "Vokera", "model_name": "Easi-Heat Plus 29C", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 56.1, "output_kw_max": 24.45, "final_year_of_manufacture": null, "raw": ["017905", "000011", "0", "2016/Jun/01 09:16", "Vokera", "Vokera", "Easi-Heat Plus 29C", "", "47-364-30", "2016", "current", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "24.45", "24.45", "", "", "88.4", "79.8", "", "56.1", "", "2", "", "", "104", "1", "2", "38", "6", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.1", "97.7", "", "", "", "", "95.9"]} -{"pcdb_id": 17906, "brand_name": "Glow-worm", "model_name": "Betacom3 24c", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 56.3, "output_kw_max": 20.3, "final_year_of_manufacture": null, "raw": ["017906", "000207", "0", "2016/Jun/01 10:03", "Glow-worm", "Glow-worm", "Betacom3 24c", "", "47-019-41", "2016", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "20.3", "20.3", "", "", "88.6", "80.0", "", "56.3", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.6", "97.8", "", "", "", "", "96.2"]} -{"pcdb_id": 17908, "brand_name": "Glow-worm", "model_name": "Betacom3 30c", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 56.3, "output_kw_max": 15.2, "final_year_of_manufacture": null, "raw": ["017908", "000207", "0", "2016/Jun/01 10:03", "Glow-worm", "Glow-worm", "Betacom3 30c", "", "47-019-42", "2016", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "15.2", "15.2", "", "", "88.6", "80.0", "", "56.3", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.6", "97.8", "", "", "", "", "96.2"]} -{"pcdb_id": 17909, "brand_name": "Vaillant", "model_name": "ecoTEC plus 624 H system A", "model_qualifier": "VU GB 246/5-5 A R4", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 24.4, "final_year_of_manufacture": 2017, "raw": ["017909", "000031", "0", "2019/Mar/04 10:10", "Vaillant", "Vaillant", "ecoTEC plus 624 H system A", "VU GB 246/5-5 A R4", "41-044-82", "2015", "2017", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "24.4", "24.4", "", "", "89.2", "80.2", "", "58.6", "", "2", "0", "", "102", "1", "2", "29", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.7", "97.1", "", "", "", "", "95.7"]} -{"pcdb_id": 17910, "brand_name": "Vaillant", "model_name": "ecoTEC plus 637 H system A", "model_qualifier": "VU GB 376/5-5 A R4", "winter_efficiency_pct": 89.8, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 59.0, "output_kw_max": 37.9, "final_year_of_manufacture": 2017, "raw": ["017910", "000031", "0", "2019/Mar/04 10:11", "Vaillant", "Vaillant", "ecoTEC plus 637 H system A", "VU GB 376/5-5 A R4", "41-044-85", "2015", "2017", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "37.9", "37.9", "", "", "89.8", "80.8", "", "59.0", "", "2", "0", "", "102", "1", "2", "45", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.1", "98.4", "", "", "", "", "96.8"]} -{"pcdb_id": 17912, "brand_name": "Vaillant", "model_name": "ecoTEC plus 825 H combi A", "model_qualifier": "VUW GB 256/5-5 R4", "winter_efficiency_pct": 89.5, "summer_efficiency_pct": 80.9, "comparative_hot_water_efficiency_pct": 56.9, "output_kw_max": 19.0, "final_year_of_manufacture": 2015, "raw": ["017912", "000031", "0", "2019/Mar/04 10:14", "Vaillant", "Vaillant", "ecoTEC plus 825 H combi A", "VUW GB 256/5-5 R4", "41-044-57", "2015", "2015", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "19.0", "19.0", "", "", "89.5", "80.9", "", "56.9", "", "2", "0", "", "104", "1", "2", "29", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "", "", "0005", "", "", "", "", "", "", "", "", "89.8", "97.8", "", "", "", "", "96.3"]} -{"pcdb_id": 17913, "brand_name": "Vaillant", "model_name": "ecoTEC plus 835 H combi A", "model_qualifier": "VUW GB 356/5-5 R4", "winter_efficiency_pct": 89.5, "summer_efficiency_pct": 80.9, "comparative_hot_water_efficiency_pct": 56.9, "output_kw_max": 30.4, "final_year_of_manufacture": 2015, "raw": ["017913", "000031", "0", "2019/Mar/04 10:15", "Vaillant", "Vaillant", "ecoTEC plus 835 H combi A", "VUW GB 356/5-5 R4", "41-044-53", "2015", "2015", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "30.4", "30.4", "", "", "89.5", "80.9", "", "56.9", "", "2", "0", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "", "", "0005", "", "", "", "", "", "", "", "", "89.8", "97.8", "", "", "", "", "96.3"]} -{"pcdb_id": 17914, "brand_name": "Vaillant", "model_name": "ecoTEC plus 838 H combi A", "model_qualifier": "VUW GB 386/5-5 A R4", "winter_efficiency_pct": 89.6, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 56.9, "output_kw_max": 28.6, "final_year_of_manufacture": 2015, "raw": ["017914", "000031", "0", "2019/Mar/04 10:21", "Vaillant", "Vaillant", "ecoTEC plus 838 H combi A", "VUW GB 386/5-5 A R4", "41-044-60", "2015", "2015", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "28.6", "28.6", "", "", "89.6", "81.0", "", "56.9", "", "2", "0", "", "104", "1", "2", "28", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "", "", "0005", "", "", "", "", "", "", "", "", "90.3", "97.7", "", "", "", "", "96.3"]} -{"pcdb_id": 17915, "brand_name": "Vaillant", "model_name": "ecoTEC plus 938 H combi A", "model_qualifier": "VUI GB 386/5-5 A R4", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 80.6, "comparative_hot_water_efficiency_pct": 56.7, "output_kw_max": 28.3, "final_year_of_manufacture": 2015, "raw": ["017915", "000031", "0", "2019/Mar/04 10:24", "Vaillant", "Vaillant", "ecoTEC plus 938 H combi A", "VUI GB 386/5-5 A R4", "41-044-61", "2015", "2015", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "28.3", "28.3", "", "", "89.2", "80.6", "", "56.7", "", "2", "0", "", "104", "1", "2", "28", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "", "", "0005", "", "", "", "", "", "", "", "", "90.1", "96.8", "", "", "", "", "95.5"]} -{"pcdb_id": 17916, "brand_name": "Vaillant", "model_name": "ecoTEC pro 24 H combi A", "model_qualifier": "VUW GB 246/5-3 A R4", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 56.6, "output_kw_max": 18.4, "final_year_of_manufacture": 2017, "raw": ["017916", "000031", "0", "2019/Mar/04 10:28", "Vaillant", "Vaillant", "ecoTEC pro 24 H combi A", "VUW GB 246/5-3 A R4", "47-044-54", "2015", "2017", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "18.4", "18.4", "", "", "89.1", "80.5", "", "56.6", "", "2", "0", "", "104", "1", "2", "26", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "", "", "0005", "", "", "", "", "", "", "", "", "89.9", "96.5", "", "", "", "", "95.3"]} -{"pcdb_id": 17917, "brand_name": "Vaillant", "model_name": "ecoTEC pro 30 H combi A", "model_qualifier": "VUW GB 306/5-3 R4", "winter_efficiency_pct": 89.5, "summer_efficiency_pct": 80.9, "comparative_hot_water_efficiency_pct": 56.9, "output_kw_max": 24.3, "final_year_of_manufacture": 2017, "raw": ["017917", "000031", "0", "2019/Mar/04 10:33", "Vaillant", "Vaillant", "ecoTEC pro 30 H combi A", "VUW GB 306/5-3 R4", "47-044-52", "2015", "2017", "2", "2", "1", "2", "0", "", "", "2", "2", "1", "24.3", "24.3", "", "", "89.5", "80.9", "", "56.9", "", "2", "0", "", "104", "1", "2", "42", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "", "", "0005", "", "", "", "", "", "", "", "", "89.5", "97.7", "", "", "", "", "96.2"]} -{"pcdb_id": 17918, "brand_name": "Navien", "model_name": "NCB-24LDWE", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 86.6, "comparative_hot_water_efficiency_pct": 69.6, "output_kw_max": 19.5, "final_year_of_manufacture": null, "raw": ["017918", "000265", "0", "2020/Jun/02 08:31", "KD Navien", "Navien", "NCB-24LDWE", "", "47-709-01", "2014", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "19.5", "19.5", "", "", "88.4", "86.6", "", "69.6", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "", "0", "", "", "", "", "1", "7.565", "0.209", "0.0115", "1.36183", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "87.8", "97.8", "", "", "", "", "95.9"]} -{"pcdb_id": 17919, "brand_name": "Navien", "model_name": "NCB-28LDWE", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 86.6, "comparative_hot_water_efficiency_pct": 68.8, "output_kw_max": 23.4, "final_year_of_manufacture": null, "raw": ["017919", "000265", "0", "2020/Jun/02 08:43", "KD Navien", "Navien", "NCB-28LDWE", "", "47-709-02", "2014", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "23.4", "23.4", "", "", "88.5", "86.6", "", "68.8", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "", "0", "", "", "", "", "1", "7.651", "0.235", "0.006", "1.47667", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "87.8", "98.1", "", "", "", "", "96.2"]} -{"pcdb_id": 17920, "brand_name": "Navien", "model_name": "NCB-34LDWE", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 86.7, "comparative_hot_water_efficiency_pct": 69.1, "output_kw_max": 28.3, "final_year_of_manufacture": null, "raw": ["017920", "000265", "0", "2020/Jun/02 08:49", "KD Navien", "Navien", "NCB-34LDWE", "", "47-709-03", "2014", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28.3", "28.3", "", "", "88.4", "86.7", "", "69.1", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "", "0", "", "", "", "", "1", "7.623", "0.224", "0.0025", "1.4727", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "87.9", "97.8", "", "", "", "", "95.9"]} -{"pcdb_id": 17921, "brand_name": "Navien", "model_name": "NCB-40LDWE", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 86.7, "comparative_hot_water_efficiency_pct": 69.4, "output_kw_max": 33.2, "final_year_of_manufacture": null, "raw": ["017921", "000265", "0", "2020/Jun/02 08:55", "KD Navien", "Navien", "NCB-40LDWE", "", "47-709-04", "2014", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "33.2", "33.2", "", "", "88.5", "86.7", "", "69.4", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "", "0", "", "", "", "", "1", "7.593", "0.223", "0.005", "1.42923", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "87.9", "98.0", "", "", "", "", "96.1"]} -{"pcdb_id": 17922, "brand_name": "Potterton", "model_name": "PROMAX ULTRA COMBI 24 ErP", "model_qualifier": "", "winter_efficiency_pct": 89.5, "summer_efficiency_pct": 80.9, "comparative_hot_water_efficiency_pct": 56.9, "output_kw_max": 20.0, "final_year_of_manufacture": null, "raw": ["017922", "000005", "0", "2016/Jun/20 15:32", "Baxi Heating UK", "Potterton", "PROMAX ULTRA COMBI 24 ErP", "", "GC No. 47-393-54", "2015", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "20", "20", "", "", "89.5", "80.9", "", "56.9", "", "2", "1", "", "104", "1", "2", "85", "3", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.0", "100.2", "", "", "", "", "98.3"]} -{"pcdb_id": 17923, "brand_name": "Potterton", "model_name": "PROMAX ULTRA COMBI 28 ErP", "model_qualifier": "", "winter_efficiency_pct": 89.5, "summer_efficiency_pct": 80.9, "comparative_hot_water_efficiency_pct": 56.9, "output_kw_max": 24.0, "final_year_of_manufacture": null, "raw": ["017923", "000005", "0", "2016/Jun/20 15:32", "Baxi Heating UK", "Potterton", "PROMAX ULTRA COMBI 28 ErP", "", "GC No. 47-393-55", "2015", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "89.5", "80.9", "", "56.9", "", "2", "1", "", "104", "1", "2", "90", "3", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.9", "100.2", "", "", "", "", "98.2"]} -{"pcdb_id": 17925, "brand_name": "Potterton", "model_name": "PROMAX ULTRA COMBI 33 ErP", "model_qualifier": "", "winter_efficiency_pct": 89.6, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 56.9, "output_kw_max": 28.0, "final_year_of_manufacture": null, "raw": ["017925", "000005", "0", "2016/Jun/20 15:32", "Baxi Heating UK", "Potterton", "PROMAX ULTRA COMBI 33 ErP", "", "GC No. 47-393-56", "2015", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "28", "28", "", "", "89.6", "81.0", "", "56.9", "", "2", "1", "", "104", "1", "2", "95", "3", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.1", "100.3", "", "", "", "", "98.4"]} -{"pcdb_id": 17926, "brand_name": "Potterton", "model_name": "PROMAX ULTRA COMBI 40 ErP", "model_qualifier": "", "winter_efficiency_pct": 89.5, "summer_efficiency_pct": 80.9, "comparative_hot_water_efficiency_pct": 56.9, "output_kw_max": 32.0, "final_year_of_manufacture": null, "raw": ["017926", "000005", "0", "2016/Jun/20 15:33", "Baxi Heating UK", "Potterton", "PROMAX ULTRA COMBI 40 ErP", "", "GC No. 47-393-57", "2015", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "32", "32", "", "", "89.5", "80.9", "", "56.9", "", "2", "1", "", "104", "1", "2", "100", "3", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.9", "100.2", "", "", "", "", "98.2"]} -{"pcdb_id": 17927, "brand_name": "Baxi", "model_name": "124 COMBI", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 86.7, "comparative_hot_water_efficiency_pct": 77.6, "output_kw_max": 20.0, "final_year_of_manufacture": null, "raw": ["017927", "000005", "0", "2016/Jul/20 12:18", "Baxi Heating UK", "Baxi", "124 COMBI", "", "47-077-25", "2016", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "20", "20", "", "", "88.5", "86.7", "", "77.6", "", "2", "", "", "104", "1", "2", "42", "3", "0", "", "", "", "0", "", "", "", "", "1", "6.786", "0.098", "0.0043", "0.65911", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "98.0", "", "", "", "", "96.1"]} -{"pcdb_id": 17928, "brand_name": "Baxi", "model_name": "128 COMBI", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 86.7, "comparative_hot_water_efficiency_pct": 77.3, "output_kw_max": 24.0, "final_year_of_manufacture": null, "raw": ["017928", "000005", "0", "2016/Jul/20 12:18", "Baxi Heating UK", "Baxi", "128 COMBI", "", "47-077-26", "2016", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "88.5", "86.7", "", "77.3", "", "2", "", "", "104", "1", "2", "42", "3", "0", "", "", "", "0", "", "", "", "", "1", "6.813", "0.098", "0.0044", "0.68225", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "98.0", "", "", "", "", "96.1"]} -{"pcdb_id": 17929, "brand_name": "Ideal", "model_name": "LOGIC COMBI", "model_qualifier": "ESP1 35", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 81.0, "output_kw_max": 24.2, "final_year_of_manufacture": null, "raw": ["017929", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "LOGIC COMBI", "ESP1 35", "47-349-23", "2016", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "89.0", "87.3", "", "81.0", "", "2", "", "", "104", "1", "2", "42", "5", "0", "", "", "", "0", "", "", "", "", "1", "6.502", "0.074", "0.0024", "0.44376", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "", "", "", "", "90.0", "98.6", "", "", "", "", "96.9"]} -{"pcdb_id": 17930, "brand_name": "Viessmann", "model_name": "Vitodens 100-W", "model_qualifier": "B1KC-35", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 88.2, "comparative_hot_water_efficiency_pct": 73.2, "output_kw_max": 32.1, "final_year_of_manufacture": null, "raw": ["017930", "000033", "0", "2020/Apr/09 16:05", "Viessmann", "Viessmann", "Vitodens 100-W", "B1KC-35", "47-819-42", "2016", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "32.1", "32.1", "", "", "88.5", "88.2", "", "73.2", "", "2", "", "", "104", "1", "2", "25", "58", "0", "", "", "", "0", "", "", "", "", "2", "7.19", "0.142", "0.0", "1.07553", "13.03", "0.161", "0.0", "1.05261", "0.0", "", "", "", "0035", "", "", "", "", "", "", "", "", "88.1", "97.9", "", "", "", "", "96.1"]} -{"pcdb_id": 17931, "brand_name": "Viessmann", "model_name": "Vitodens 100-W", "model_qualifier": "B1KC-30", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 88.2, "comparative_hot_water_efficiency_pct": 71.2, "output_kw_max": 27.5, "final_year_of_manufacture": null, "raw": ["017931", "000033", "0", "2020/Apr/09 16:05", "Viessmann", "Viessmann", "Vitodens 100-W", "B1KC-30", "47-819-41", "2016", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "27.5", "27.5", "", "", "88.5", "88.2", "", "71.2", "", "2", "", "", "104", "1", "2", "24", "58", "0", "", "", "", "0", "", "", "", "", "2", "7.4", "0.155", "0.0", "1.28491", "13.12", "0.174", "0.0", "1.25407", "0.0", "", "", "", "0035", "", "", "", "", "", "", "", "", "88.4", "97.8", "", "", "", "", "96.1"]} -{"pcdb_id": 17932, "brand_name": "Viessmann", "model_name": "Vitodens 100-W", "model_qualifier": "B1KC-26", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 87.8, "comparative_hot_water_efficiency_pct": 66.8, "output_kw_max": 23.8, "final_year_of_manufacture": null, "raw": ["017932", "000033", "0", "2020/Apr/09 16:04", "Viessmann", "Viessmann", "Vitodens 100-W", "B1KC-26", "47-819-40", "2016", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "23.8", "23.8", "", "", "88.1", "87.8", "", "66.8", "", "2", "", "", "104", "1", "2", "22", "59", "0", "", "", "", "0", "", "", "", "", "2", "7.88", "0.153", "0.0", "1.73709", "13.84", "0.175", "0.0", "1.68304", "0.0", "", "", "", "0035", "", "", "", "", "", "", "", "", "88.0", "97.0", "", "", "", "", "95.3"]} -{"pcdb_id": 17933, "brand_name": "Viessmann", "model_name": "Vitodens 100-W", "model_qualifier": "B1HC-35", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 32.1, "final_year_of_manufacture": null, "raw": ["017933", "000033", "0", "2017/Feb/20 10:57", "Viessmann", "Viessmann", "Vitodens 100-W", "B1HC-35", "41-819-43", "2016", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "32.1", "32.1", "", "", "88.5", "79.5", "", "58.0", "", "2", "", "", "102", "1", "2", "25", "58", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "", "", "", "", "88.1", "97.9", "", "", "", "", "96.1"]} -{"pcdb_id": 17934, "brand_name": "Viessmann", "model_name": "Vitodens 100-W", "model_qualifier": "B1HC-30", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 27.5, "final_year_of_manufacture": null, "raw": ["017934", "000033", "0", "2017/Feb/20 10:57", "Viessmann", "Viessmann", "Vitodens 100-W", "B1HC-30", "41-819-42", "2016", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "27.5", "27.5", "", "", "88.5", "79.5", "", "58.1", "", "2", "", "", "102", "1", "2", "24", "58", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "", "", "", "", "88.4", "97.8", "", "", "", "", "96.1"]} -{"pcdb_id": 17935, "brand_name": "Viessmann", "model_name": "Vitodens 100-W", "model_qualifier": "B1HC-26", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 23.8, "final_year_of_manufacture": null, "raw": ["017935", "000033", "0", "2017/Feb/20 10:57", "Viessmann", "Viessmann", "Vitodens 100-W", "B1HC-26", "41-819-41", "2016", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "23.8", "23.8", "", "", "88.1", "79.1", "", "57.8", "", "2", "", "", "102", "1", "2", "22", "59", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "", "", "", "", "88.0", "97.0", "", "", "", "", "95.3"]} -{"pcdb_id": 17936, "brand_name": "Viessmann", "model_name": "Vitodens 100-W", "model_qualifier": "B1HC-19", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 17.4, "final_year_of_manufacture": null, "raw": ["017936", "000033", "0", "2017/Feb/20 10:57", "Viessmann", "Viessmann", "Vitodens 100-W", "B1HC-19", "41-819-40", "2016", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "17.4", "17.4", "", "", "88.3", "79.3", "", "57.9", "", "2", "", "", "102", "1", "2", "19", "60", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "", "", "", "", "87.8", "97.7", "", "", "", "", "95.8"]} -{"pcdb_id": 17937, "brand_name": "Viessmann", "model_name": "Vitodens 111-W", "model_qualifier": "B1LD - 35kW", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 86.2, "comparative_hot_water_efficiency_pct": 59.3, "output_kw_max": 32.0, "final_year_of_manufacture": null, "raw": ["017937", "000033", "0", "2020/Apr/09 16:03", "Viessmann", "Viessmann", "Vitodens 111-W", "B1LD - 35kW", "", "2016", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "32", "32", "", "", "88.5", "86.2", "", "59.3", "", "2", "", "", "106", "1", "2", "25", "58", "1", "", "0", "46", "0", "10", "2", "", "", "2", "8.88", "0.173", "0.0", "2.71671", "14.95", "0.205", "0.0", "2.48464", "0.0", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.6", "97.8", "", "", "", "", "96.1"]} -{"pcdb_id": 17938, "brand_name": "Viessmann", "model_name": "Vitodens 111-W", "model_qualifier": "B1LD - 26kW", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 87.1, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 23.8, "final_year_of_manufacture": null, "raw": ["017938", "000033", "0", "2020/Apr/09 16:02", "Viessmann", "Viessmann", "Vitodens 111-W", "B1LD - 26kW", "", "2016", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "23.8", "23.8", "", "", "88.4", "87.1", "", "58.3", "", "2", "", "", "106", "1", "2", "22", "59", "1", "1", "0", "46", "0", "10", "2", "", "", "2", "9.04", "0.177", "0.0", "2.85619", "15.05", "0.214", "0.0001", "2.7211", "0.0", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.1", "97.8", "", "", "", "", "95.9"]} -{"pcdb_id": 17939, "brand_name": "Baxi", "model_name": "200", "model_qualifier": "224 COMBI", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 56.1, "output_kw_max": 20.0, "final_year_of_manufacture": null, "raw": ["017939", "000005", "0", "2021/Feb/18 10:24", "Baxi Heating UK", "Baxi", "200", "224 COMBI", "47-077-21", "2016", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "20", "20", "", "", "88.4", "79.8", "", "56.1", "", "2", "", "", "104", "1", "2", "28", "3", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "88.1", "97.8", "", "", "", "", "96.0"]} -{"pcdb_id": 17940, "brand_name": "Baxi", "model_name": "200", "model_qualifier": "228 COMBI", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 56.1, "output_kw_max": 24.0, "final_year_of_manufacture": null, "raw": ["017940", "000005", "0", "2021/Feb/18 10:29", "Baxi Heating UK", "Baxi", "200", "228 COMBI", "47-077-22", "2016", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "88.4", "79.8", "", "56.1", "", "2", "", "", "104", "1", "2", "38", "3", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "88.0", "97.8", "", "", "", "", "95.9"]} -{"pcdb_id": 17941, "brand_name": "Baxi", "model_name": "400", "model_qualifier": "424 COMBI", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 56.1, "output_kw_max": 20.0, "final_year_of_manufacture": null, "raw": ["017941", "000005", "0", "2021/Feb/18 10:33", "Baxi Heating UK", "Baxi", "400", "424 COMBI", "47-077-23", "2016", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "20", "20", "", "", "88.4", "79.8", "", "56.1", "", "2", "", "", "104", "1", "2", "28", "3", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "88.1", "97.8", "", "", "", "", "96.0"]} -{"pcdb_id": 17942, "brand_name": "Baxi", "model_name": "400", "model_qualifier": "428 COMBI", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 56.1, "output_kw_max": 24.0, "final_year_of_manufacture": null, "raw": ["017942", "000005", "0", "2021/Feb/18 10:36", "Baxi Heating UK", "Baxi", "400", "428 COMBI", "47-077-24", "2016", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "88.4", "79.8", "", "56.1", "", "2", "", "", "104", "1", "2", "38", "3", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "88.0", "97.8", "", "", "", "", "95.9"]} -{"pcdb_id": 17943, "brand_name": "Vokera", "model_name": "Maxim", "model_qualifier": "25", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 86.6, "comparative_hot_water_efficiency_pct": 72.1, "output_kw_max": 19.5, "final_year_of_manufacture": null, "raw": ["017943", "000011", "0", "2016/Aug/22 13:28", "Vokera", "Vokera", "Maxim", "25", "47-364-31", "2016", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "19.5", "19.5", "", "", "88.5", "86.6", "", "72.1", "", "2", "", "", "104", "1", "2", "29", "6", "0", "", "", "", "0", "", "", "", "", "1", "7.304", "0.103", "0.004", "1.15471", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "98.1", "", "", "", "", "96.2"]} -{"pcdb_id": 17944, "brand_name": "Vokera", "model_name": "Maxim", "model_qualifier": "29", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 86.7, "comparative_hot_water_efficiency_pct": 72.9, "output_kw_max": 24.45, "final_year_of_manufacture": null, "raw": ["017944", "000011", "0", "2016/Aug/22 13:28", "Vokera", "Vokera", "Maxim", "29", "47-364-32", "2016", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.45", "24.45", "", "", "88.4", "86.7", "", "72.9", "", "2", "", "", "104", "1", "2", "38", "6", "0", "", "", "", "0", "", "", "", "", "1", "7.22", "0.117", "0.009", "1.0518", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.1", "97.7", "", "", "", "", "95.9"]} -{"pcdb_id": 17945, "brand_name": "Biasi", "model_name": "ALNOVIA 18R", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 17.4, "final_year_of_manufacture": null, "raw": ["017945", "000263", "0", "2016/Oct/03 11:09", "Unical AG", "Biasi", "ALNOVIA 18R", "", "41011161", "2016", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "17.4", "17.4", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "85", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.1", "97.8", "", "", "", "", "95.9"]} -{"pcdb_id": 17946, "brand_name": "Biasi", "model_name": "ALNOVIA 18S", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 56.1, "output_kw_max": 17.4, "final_year_of_manufacture": null, "raw": ["017946", "000263", "0", "2016/Oct/03 11:10", "Unical AG", "Biasi", "ALNOVIA 18S", "", "41011159", "2016", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "17.4", "17.4", "", "", "88.4", "79.8", "", "56.1", "", "2", "", "", "104", "1", "2", "85", "3", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.1", "97.8", "", "", "", "", "95.9"]} -{"pcdb_id": 17947, "brand_name": "Biasi", "model_name": "ALNOVIA 28R", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 27.2, "final_year_of_manufacture": null, "raw": ["017947", "000263", "0", "2016/Oct/03 11:10", "Unical AG", "Biasi", "ALNOVIA 28R", "", "41011165", "2016", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "27.2", "27.2", "", "", "88.5", "79.5", "", "58.0", "", "2", "", "", "102", "1", "2", "11", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "97.9", "", "", "", "", "96.1"]} -{"pcdb_id": 17948, "brand_name": "Biasi", "model_name": "ALNOVIA 28S", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 56.2, "output_kw_max": 27.2, "final_year_of_manufacture": null, "raw": ["017948", "000263", "0", "2016/Oct/03 11:10", "Unical AG", "Biasi", "ALNOVIA 28S", "", "41011163", "2016", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "27.2", "27.2", "", "", "88.5", "79.9", "", "56.2", "", "2", "", "", "104", "1", "2", "11", "3", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "97.9", "", "", "", "", "96.1"]} -{"pcdb_id": 17949, "brand_name": "Elco", "model_name": "THISION S PLUS 46", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 44.7, "final_year_of_manufacture": null, "raw": ["017949", "000303", "0", "2017/Apr/05 08:19", "Elco Heating Solutions Ltd", "Elco", "THISION S PLUS 46", "", "", "2016", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "44.7", "44.7", "", "", "88.8", "79.8", "", "58.3", "", "2", "", "", "102", "1", "2", "125", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "98.8", "", "", "", "", "96.8"]} -{"pcdb_id": 17950, "brand_name": "Elco", "model_name": "THISION S PLUS 54", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 52.9, "final_year_of_manufacture": null, "raw": ["017950", "000303", "0", "2016/Nov/16 10:56", "Elco Heating Solutions Ltd", "Elco", "THISION S PLUS 54", "", "", "2016", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "52.9", "52.9", "", "", "88.8", "79.8", "", "58.3", "", "2", "", "", "102", "1", "2", "143", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "98.8", "", "", "", "", "96.8"]} -{"pcdb_id": 17951, "brand_name": "Elco", "model_name": "THISION S PLUS 34", "model_qualifier": "", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 33.6, "final_year_of_manufacture": null, "raw": ["017951", "000303", "0", "2016/Nov/16 10:56", "Elco Heating Solutions Ltd", "Elco", "THISION S PLUS 34", "", "", "2016", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "33.6", "33.6", "", "", "88.7", "79.7", "", "58.3", "", "2", "", "", "102", "1", "2", "93", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "98.7", "", "", "", "", "96.7"]} -{"pcdb_id": 17952, "brand_name": "Vaillant", "model_name": "ecoTEC exclusive 627", "model_qualifier": "VU 256/5-7 (H-GB)", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 25.0, "final_year_of_manufacture": null, "raw": ["017952", "000031", "0", "2018/Apr/03 14:01", "Vaillant", "Vaillant", "ecoTEC exclusive 627", "VU 256/5-7 (H-GB)", "41-694-02", "2016", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "25", "25", "", "", "88.9", "79.9", "", "58.4", "", "2", "", "", "102", "1", "2", "32", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0045", "", "", "", "", "", "", "", "", "89.0", "98.7", "", "", "", "", "96.9"]} -{"pcdb_id": 17953, "brand_name": "Vaillant", "model_name": "ecoTEC exclusive 835", "model_qualifier": "VUW 356/5-7 (H-GB)", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 85.0, "comparative_hot_water_efficiency_pct": 84.6, "output_kw_max": 32.7, "final_year_of_manufacture": null, "raw": ["017953", "000031", "0", "2021/Feb/15 12:59", "Vaillant", "Vaillant", "ecoTEC exclusive 835", "VUW 356/5-7 (H-GB)", "47-044-66", "2016", "current", "1", "2", "1", "2", "1", "", "", "2", "2", "2", "32.7", "32.7", "", "", "89.1", "85.0", "", "84.6", "", "2", "", "", "104", "1", "2", "31", "2", "0", "", "", "", "0", "", "", "", "", "2", "6.224", "0.081", "0.006", "0.13712", "12.3532", "0.0833", "0.0005", "0.0", "0.00006", "", "", "", "0045", "", "", "", "", "", "", "", "", "89.3", "99.0", "", "", "", "", "97.2"]} -{"pcdb_id": 17954, "brand_name": "Vaillant", "model_name": "ecoTEC exclusive 843", "model_qualifier": "VUW 436/5-7 (H-GB)", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 83.8, "comparative_hot_water_efficiency_pct": 86.9, "output_kw_max": 40.2, "final_year_of_manufacture": null, "raw": ["017954", "000031", "0", "2020/Nov/17 08:45", "Vaillant", "Vaillant", "ecoTEC exclusive 843", "VUW 436/5-7 (H-GB)", "47-044-67", "2016", "current", "1", "2", "1", "2", "1", "", "", "2", "2", "2", "40.2", "40.2", "", "", "89.0", "83.8", "", "86.9", "", "2", "", "", "104", "1", "2", "31", "2", "0", "", "", "", "0", "", "", "", "", "2", "6.057", "0.081", "0.006", "0.0", "12.277", "0.1149", "0.0009", "0.0", "0.00005", "", "", "", "0045", "", "", "", "", "", "", "", "", "89.1", "98.9", "", "", "", "", "97.1"]} -{"pcdb_id": 17955, "brand_name": "Ideal", "model_name": "LOGIC COMBI", "model_qualifier": "ESP1 24", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 80.1, "output_kw_max": 24.2, "final_year_of_manufacture": null, "raw": ["017955", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "LOGIC COMBI", "ESP1 24", "47-349-21", "2016", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "89.0", "87.3", "", "80.1", "", "2", "", "", "104", "1", "2", "29", "5", "0", "", "", "", "0", "", "", "", "", "1", "6.575", "0.075", "0.0042", "0.50397", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "", "", "", "", "90.0", "98.6", "", "", "", "", "96.9"]} -{"pcdb_id": 17956, "brand_name": "Ideal", "model_name": "LOGIC COMBI", "model_qualifier": "ESP1 30", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 80.8, "output_kw_max": 24.2, "final_year_of_manufacture": null, "raw": ["017956", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "LOGIC COMBI", "ESP1 30", "47-349-22", "2016", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "89.0", "87.3", "", "80.8", "", "2", "", "", "104", "1", "2", "31", "5", "0", "", "", "", "0", "", "", "", "", "1", "6.521", "0.074", "0.003", "0.45861", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "", "", "", "", "90.0", "98.6", "", "", "", "", "96.9"]} -{"pcdb_id": 17957, "brand_name": "Warmflow", "model_name": "UTILITY COMBI 70 HE ECO", "model_qualifier": "UC70HEE", "winter_efficiency_pct": 87.5, "summer_efficiency_pct": 81.5, "comparative_hot_water_efficiency_pct": 52.4, "output_kw_max": 21.0, "final_year_of_manufacture": null, "raw": ["017957", "000063", "0", "2024/Jan/31 10:17", "Warmflow Engineering", "Warmflow", "UTILITY COMBI 70 HE ECO", "UC70HEE", "", "2016", "current", "4", "1", "1", "2", "0", "", "", "2", "3", "2", "21.0", "21.0", "", "", "87.5", "81.5", "", "52.4", "", "2", "", "", "203", "1", "1", "200", "0", "1", "2", "", "50", "0", "50", "2", "55", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.3", "93.3", "", "", "", "", "92.9"]} -{"pcdb_id": 17958, "brand_name": "Vaillant", "model_name": "ecoFIT sustain 825", "model_qualifier": "VUW 256/6-3 (H-GB)", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 77.0, "output_kw_max": 18.3, "final_year_of_manufacture": null, "raw": ["017958", "000031", "0", "2020/Nov/23 12:20", "Vaillant", "Vaillant", "ecoFIT sustain 825", "VUW 256/6-3 (H-GB)", "47-044-71", "2016", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "18.3", "18.3", "", "", "88.7", "75.0", "", "77.0", "", "2", "", "", "104", "1", "2", "25", "2", "0", "", "", "", "0", "", "", "", "", "2", "6.835", "0.096", "0.0115", "0.70684", "13.761", "0.11", "0.002", "0.0", "0.0001", "", "", "", "0045", "", "", "", "", "", "", "", "", "89.7", "97.8", "", "", "", "", "96.2"]} -{"pcdb_id": 17959, "brand_name": "Vaillant", "model_name": "ecoFIT sustain 830", "model_qualifier": "VUW 306/6-3 (H-GB)", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 76.2, "comparative_hot_water_efficiency_pct": 75.8, "output_kw_max": 18.3, "final_year_of_manufacture": null, "raw": ["017959", "000031", "0", "2021/Feb/15 13:01", "Vaillant", "Vaillant", "ecoFIT sustain 830", "VUW 306/6-3 (H-GB)", "47-044-72", "2016", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "18.3", "18.3", "", "", "88.7", "76.2", "", "75.8", "", "2", "", "", "104", "1", "2", "21", "2", "0", "", "", "0", "0", "", "", "", "", "2", "6.945", "0.085", "0.0115", "0.81337", "13.7495", "0.0981", "0.001", "0.0", "0.00011", "", "", "", "0045", "", "", "", "", "", "", "", "", "89.7", "97.8", "", "", "", "", "96.2"]} -{"pcdb_id": 17960, "brand_name": "Vaillant", "model_name": "ecoFIT sustain 835", "model_qualifier": "VUW 356/6-3 (H-GB)", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 76.4, "comparative_hot_water_efficiency_pct": 76.1, "output_kw_max": 18.3, "final_year_of_manufacture": null, "raw": ["017960", "000031", "0", "2020/Nov/17 08:33", "Vaillant", "Vaillant", "ecoFIT sustain 835", "VUW 356/6-3 (H-GB)", "47-044-73", "2016", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "18.3", "18.3", "", "", "88.7", "76.4", "", "76.1", "", "2", "", "", "104", "1", "2", "20", "2", "0", "", "", "", "0", "", "", "", "", "2", "6.921", "0.096", "0.0045", "0.83104", "13.751", "0.1246", "0.0005", "0.0", "0.00004", "", "", "", "0045", "", "", "", "", "", "", "", "", "89.7", "97.8", "", "", "", "", "96.2"]} -{"pcdb_id": 17962, "brand_name": "Vaillant", "model_name": "ecoFIT pure 412", "model_qualifier": "VU 126/6-3 OV (H-GB)", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 12.3, "final_year_of_manufacture": null, "raw": ["017962", "000031", "0", "2017/Jul/17 09:51", "Vaillant", "Vaillant", "ecoFIT pure 412", "VU 126/6-3 OV (H-GB)", "41-694-08", "2016", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "12.3", "12.3", "", "", "89.1", "80.1", "", "58.5", "", "2", "", "", "102", "1", "2", "19", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0045", "", "", "", "", "", "", "", "", "89.3", "99.0", "", "", "", "", "97.2"]} -{"pcdb_id": 17963, "brand_name": "Vaillant", "model_name": "ecoFIT pure 415", "model_qualifier": "VU 156/6-3 OV (H-GB)", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 15.3, "final_year_of_manufacture": null, "raw": ["017963", "000031", "0", "2017/Jul/17 09:52", "Vaillant", "Vaillant", "ecoFIT pure 415", "VU 156/6-3 OV (H-GB)", "41-694-09", "2016", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "15.3", "15.3", "", "", "89.1", "80.1", "", "58.5", "", "2", "", "", "102", "1", "2", "24", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0045", "", "", "", "", "", "", "", "", "89.1", "99.1", "", "", "", "", "97.2"]} -{"pcdb_id": 17964, "brand_name": "Vaillant", "model_name": "ecoFIT pure 418", "model_qualifier": "VU 186/6-3 OV (H-GB)", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 18.4, "final_year_of_manufacture": null, "raw": ["017964", "000031", "0", "2017/Jul/17 09:52", "Vaillant", "Vaillant", "ecoFIT pure 418", "VU 186/6-3 OV (H-GB)", "41-694-10", "2016", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18.4", "18.4", "", "", "89.0", "80.0", "", "58.4", "", "2", "", "", "102", "1", "2", "25", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0045", "", "", "", "", "", "", "", "", "89.0", "98.9", "", "", "", "", "97.0"]} -{"pcdb_id": 17965, "brand_name": "Vaillant", "model_name": "ecoFIT pure 425", "model_qualifier": "VU 256/6-3 OV (H-GB)", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 30.0, "final_year_of_manufacture": null, "raw": ["017965", "000031", "0", "2017/Jul/17 09:53", "Vaillant", "Vaillant", "ecoFIT pure 425", "VU 256/6-3 OV (H-GB)", "41-694-11", "2016", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "30.0", "30.0", "", "", "89.0", "80.0", "", "58.4", "", "2", "", "", "102", "1", "2", "29", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0045", "", "", "", "", "", "", "", "", "89.0", "98.8", "", "", "", "", "97.0"]} -{"pcdb_id": 17966, "brand_name": "Vaillant", "model_name": "ecoFIT pure 430", "model_qualifier": "VU 306/6-3 OV (H-GB)", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 25.5, "final_year_of_manufacture": null, "raw": ["017966", "000031", "0", "2017/Jul/17 14:42", "Vaillant", "Vaillant", "ecoFIT pure 430", "VU 306/6-3 OV (H-GB)", "41-694-12", "2016", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "25.5", "25.5", "", "", "89.1", "80.1", "", "58.5", "", "2", "", "", "102", "1", "2", "37", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0045", "", "", "", "", "", "", "", "", "89.5", "99.0", "", "", "", "", "97.2"]} -{"pcdb_id": 17968, "brand_name": "Vaillant", "model_name": "ecoFIT pure 612", "model_qualifier": "VU 126/6-3 (H-GB)", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 12.3, "final_year_of_manufacture": null, "raw": ["017968", "000031", "0", "2017/Jul/17 09:53", "Vaillant", "Vaillant", "ecoFIT pure 612", "VU 126/6-3 (H-GB)", "41-694-03", "2016", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "12.3", "12.3", "", "", "89.1", "80.1", "", "58.5", "", "2", "", "", "102", "1", "2", "19", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0045", "", "", "", "", "", "", "", "", "89.3", "99.0", "", "", "", "", "97.2"]} -{"pcdb_id": 17969, "brand_name": "Vaillant", "model_name": "ecoFIT pure 615", "model_qualifier": "VU 156/6-3 (H-GB)", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 15.3, "final_year_of_manufacture": null, "raw": ["017969", "000031", "0", "2017/Jul/17 09:54", "Vaillant", "Vaillant", "ecoFIT pure 615", "VU 156/6-3 (H-GB)", "41-694-04", "2016", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "15.3", "15.3", "", "", "89.1", "80.1", "", "58.5", "", "2", "", "", "102", "1", "2", "24", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0045", "", "", "", "", "", "", "", "", "89.1", "99.1", "", "", "", "", "97.2"]} -{"pcdb_id": 17970, "brand_name": "Vaillant", "model_name": "ecoFIT pure 618", "model_qualifier": "VU 186/6-3 (H-GB)", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 18.4, "final_year_of_manufacture": null, "raw": ["017970", "000031", "0", "2017/Jul/17 09:54", "Vaillant", "Vaillant", "ecoFIT pure 618", "VU 186/6-3 (H-GB)", "41-694-05", "2016", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18.4", "18.4", "", "", "89.0", "80.0", "", "58.4", "", "2", "", "", "102", "1", "2", "25", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0045", "", "", "", "", "", "", "", "", "89.0", "98.9", "", "", "", "", "97.0"]} -{"pcdb_id": 17971, "brand_name": "Vaillant", "model_name": "ecoFIT pure 625", "model_qualifier": "VU 256/6-3 (H-GB)", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 24.7, "final_year_of_manufacture": null, "raw": ["017971", "000031", "0", "2017/Jul/17 09:54", "Vaillant", "Vaillant", "ecoFIT pure 625", "VU 256/6-3 (H-GB)", "41-694-08", "2016", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24.7", "24.7", "", "", "89.0", "80.0", "", "58.4", "", "2", "", "", "102", "1", "2", "29", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0045", "", "", "", "", "", "", "", "", "89.2", "98.8", "", "", "", "", "97.0"]} -{"pcdb_id": 17972, "brand_name": "Vaillant", "model_name": "ecoFIT pure 630", "model_qualifier": "VU 306/6-3 (H-GB)", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 25.5, "final_year_of_manufacture": null, "raw": ["017972", "000031", "0", "2017/Jul/17 09:55", "Vaillant", "Vaillant", "ecoFIT pure 630", "VU 306/6-3 (H-GB)", "41-694-07", "2016", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "25.5", "25.5", "", "", "89.2", "80.2", "", "58.5", "", "2", "", "", "102", "1", "2", "37", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0045", "", "", "", "", "", "", "", "", "89.5", "99.1", "", "", "", "", "97.3"]} -{"pcdb_id": 17973, "brand_name": "Vaillant", "model_name": "ecoFIT pure 825", "model_qualifier": "VUW 256/6-3 (H-GB)", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.4, "comparative_hot_water_efficiency_pct": 56.5, "output_kw_max": 18.4, "final_year_of_manufacture": null, "raw": ["017973", "000031", "0", "2017/Jul/17 09:55", "Vaillant", "Vaillant", "ecoFIT pure 825", "VUW 256/6-3 (H-GB)", "47-044-68", "2016", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "18.4", "18.4", "", "", "89.0", "80.4", "", "56.5", "", "2", "", "", "104", "1", "2", "25", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0045", "", "", "", "", "", "", "", "", "89.0", "98.9", "", "", "", "", "97.0"]} -{"pcdb_id": 17974, "brand_name": "Vaillant", "model_name": "ecoFIT pure 830", "model_qualifier": "VUW 306/6-3 (H-GB)", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.4, "comparative_hot_water_efficiency_pct": 56.5, "output_kw_max": 25.5, "final_year_of_manufacture": null, "raw": ["017974", "000031", "0", "2017/Nov/01 12:27", "Vaillant", "Vaillant", "ecoFIT pure 830", "VUW 306/6-3 (H-GB)", "47-044-74", "2016", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "25.5", "25.5", "", "", "89.0", "80.4", "", "56.5", "", "2", "", "", "104", "1", "2", "29", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0045", "", "", "", "", "", "", "", "", "89.0", "98.8", "", "", "", "", "97.0"]} -{"pcdb_id": 17975, "brand_name": "Vaillant", "model_name": "ecoFIT pure 835", "model_qualifier": "VUW 356/6-3 (H-GB)", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 56.6, "output_kw_max": 25.5, "final_year_of_manufacture": null, "raw": ["017975", "000031", "0", "2017/Jul/17 09:57", "Vaillant", "Vaillant", "ecoFIT pure 835", "VUW 356/6-3 (H-GB)", "47-044-70", "2016", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "25.5", "25.5", "", "", "89.1", "80.5", "", "56.6", "", "2", "", "", "104", "1", "2", "27", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0045", "", "", "", "", "", "", "", "", "89.5", "99.0", "", "", "", "", "97.2"]} -{"pcdb_id": 17976, "brand_name": "Vaillant", "model_name": "ecoTEC plus 412", "model_qualifier": "VU 126/6-5 OVZ (H-GB)", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 12.0, "final_year_of_manufacture": null, "raw": ["017976", "000031", "0", "2018/Mar/12 08:57", "Vaillant", "Vaillant", "ecoTEC plus 412", "VU 126/6-5 OVZ (H-GB)", "41-694-13", "2016", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "12", "12", "", "", "89.1", "80.1", "", "58.5", "", "2", "", "", "102", "1", "2", "19", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0045", "", "", "", "", "", "", "", "", "89.3", "99.0", "", "", "", "", "97.2"]} -{"pcdb_id": 17977, "brand_name": "Vaillant", "model_name": "ecoTEC plus 415", "model_qualifier": "VU 156/6-5 OVZ (H-GB)", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 15.0, "final_year_of_manufacture": null, "raw": ["017977", "000031", "0", "2018/Mar/12 08:58", "Vaillant", "Vaillant", "ecoTEC plus 415", "VU 156/6-5 OVZ (H-GB)", "41-694-14", "2016", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "15", "15", "", "", "89.1", "80.1", "", "58.5", "", "2", "", "", "102", "1", "2", "24", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0045", "", "", "", "", "", "", "", "", "89.1", "99.1", "", "", "", "", "97.2"]} -{"pcdb_id": 17978, "brand_name": "Vaillant", "model_name": "ecoTEC plus 418", "model_qualifier": "VU 186/6-5 OVZ (H-GB)", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 18.0, "final_year_of_manufacture": null, "raw": ["017978", "000031", "0", "2018/Mar/12 08:58", "Vaillant", "Vaillant", "ecoTEC plus 418", "VU 186/6-5 OVZ (H-GB)", "41-694-15", "2016", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18", "18", "", "", "89.0", "80.0", "", "58.4", "", "2", "", "", "102", "1", "2", "25", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0045", "", "", "", "", "", "", "", "", "89.0", "98.9", "", "", "", "", "97.0"]} -{"pcdb_id": 17979, "brand_name": "Vaillant", "model_name": "ecoTEC plus 424", "model_qualifier": "VU 246/6-5 OVZ (H-GB)", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 25.0, "final_year_of_manufacture": null, "raw": ["017979", "000031", "0", "2018/Mar/12 08:59", "Vaillant", "Vaillant", "ecoTEC plus 424", "VU 246/6-5 OVZ (H-GB)", "41-694-16", "2016", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "25", "25", "", "", "89.0", "80.0", "", "58.4", "", "2", "", "", "102", "1", "2", "29", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0045", "", "", "", "", "", "", "", "", "89.0", "98.9", "", "", "", "", "97.0"]} -{"pcdb_id": 17980, "brand_name": "Vaillant", "model_name": "ecoTEC plus 430", "model_qualifier": "VU 306/6-5 OVZ (H-GB)", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 25.0, "final_year_of_manufacture": null, "raw": ["017980", "000031", "0", "2018/Mar/12 08:59", "Vaillant", "Vaillant", "ecoTEC plus 430", "VU 306/6-5 OVZ (H-GB)", "41-694-17", "2016", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "25", "25", "", "", "89.1", "80.1", "", "58.5", "", "2", "", "", "102", "1", "2", "37", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0045", "", "", "", "", "", "", "", "", "89.5", "99.0", "", "", "", "", "97.2"]} -{"pcdb_id": 17982, "brand_name": "Ideal", "model_name": "LOGIC COMBI", "model_qualifier": "C24", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 69.8, "output_kw_max": 24.2, "final_year_of_manufacture": null, "raw": ["017982", "000008", "0", "2021/Apr/29 14:25", "Ideal Boilers", "Ideal", "LOGIC COMBI", "C24", "47-349-18", "2016", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "89.0", "87.3", "", "69.8", "", "2", "", "", "104", "1", "2", "29", "5", "0", "", "", "", "0", "", "", "", "", "1", "7.549", "0.076", "0.0026", "1.45745", "", "", "", "", "", "1", "0", "", "0035", "", "", "", "", "", "", "", "", "90.0", "98.6", "", "", "", "", "96.9"]} -{"pcdb_id": 17983, "brand_name": "Ideal", "model_name": "LOGIC COMBI", "model_qualifier": "C30", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 70.4, "output_kw_max": 24.2, "final_year_of_manufacture": null, "raw": ["017983", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "LOGIC COMBI", "C30", "47-349-19", "2016", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "89.0", "87.3", "", "70.4", "", "2", "", "", "104", "1", "2", "31", "5", "0", "", "", "", "0", "", "", "", "", "1", "7.476", "0.075", "0.0026", "1.38721", "", "", "", "", "", "1", "0", "", "0025", "", "", "", "", "", "", "", "", "90.0", "98.6", "", "", "", "", "96.9"]} -{"pcdb_id": 17984, "brand_name": "Ideal", "model_name": "LOGIC COMBI", "model_qualifier": "C35", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 71.1, "output_kw_max": 24.2, "final_year_of_manufacture": null, "raw": ["017984", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "LOGIC COMBI", "C35", "47-349-20", "2016", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "89.0", "87.3", "", "71.1", "", "2", "", "", "104", "1", "2", "42", "5", "0", "", "", "", "0", "", "", "", "", "1", "7.41", "0.074", "0.0025", "1.32349", "", "", "", "", "", "1", "0", "", "0025", "", "", "", "", "", "", "", "", "90.0", "98.6", "", "", "", "", "96.9"]} -{"pcdb_id": 17985, "brand_name": "Ideal", "model_name": "LOGIC + COMBI", "model_qualifier": "C24", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 69.8, "output_kw_max": 24.2, "final_year_of_manufacture": null, "raw": ["017985", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "LOGIC + COMBI", "C24", "47-349-15", "2016", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "89.0", "87.3", "", "69.8", "", "2", "", "", "104", "1", "2", "29", "5", "0", "", "", "", "0", "", "", "", "", "1", "7.549", "0.076", "0.0026", "1.45745", "", "", "", "", "", "1", "0", "", "0035", "", "", "", "", "", "", "", "", "90.0", "98.6", "", "", "", "", "96.9"]} -{"pcdb_id": 17986, "brand_name": "Ideal", "model_name": "LOGIC + COMBI", "model_qualifier": "C30", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 70.4, "output_kw_max": 24.2, "final_year_of_manufacture": null, "raw": ["017986", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "LOGIC + COMBI", "C30", "47-349-16", "2016", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "89.0", "87.3", "", "70.4", "", "2", "", "", "104", "1", "2", "31", "5", "0", "", "", "", "0", "", "", "", "", "1", "7.476", "0.075", "0.0026", "1.38721", "", "", "", "", "", "1", "0", "", "0035", "", "", "", "", "", "", "", "", "90.0", "98.6", "", "", "", "", "96.9"]} -{"pcdb_id": 17987, "brand_name": "Ideal", "model_name": "LOGIC + COMBI", "model_qualifier": "C35", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 71.1, "output_kw_max": 24.2, "final_year_of_manufacture": null, "raw": ["017987", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "LOGIC + COMBI", "C35", "47-349-17", "2016", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "89.0", "87.3", "", "71.1", "", "2", "", "", "104", "1", "2", "42", "5", "0", "", "", "", "0", "", "", "", "", "1", "7.41", "0.074", "0.0025", "1.32349", "", "", "", "", "", "1", "0", "", "0035", "", "", "", "", "", "", "", "", "90.0", "98.6", "", "", "", "", "96.9"]} -{"pcdb_id": 17988, "brand_name": "Keston", "model_name": "COMBI C30", "model_qualifier": "", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 70.4, "output_kw_max": 24.2, "final_year_of_manufacture": null, "raw": ["017988", "000022", "0", "2017/Feb/20 10:57", "Keston Boilers", "Keston", "COMBI C30", "", "47-930-07", "2016", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "89.0", "87.3", "", "70.4", "", "2", "", "", "104", "1", "2", "31", "5", "0", "", "", "", "0", "", "", "", "", "1", "7.476", "0.075", "0.0026", "1.38721", "", "", "", "", "", "1", "0", "", "0035", "", "", "", "", "", "", "", "", "90.0", "98.6", "", "", "", "", "96.9"]} -{"pcdb_id": 17990, "brand_name": "Keston", "model_name": "COMBI C35", "model_qualifier": "", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 71.1, "output_kw_max": 24.2, "final_year_of_manufacture": null, "raw": ["017990", "000022", "0", "2017/Feb/20 10:57", "Keston Boilers", "Keston", "COMBI C35", "", "47-930-08", "2016", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "89.0", "87.3", "", "71.1", "", "2", "", "", "104", "1", "2", "42", "5", "0", "", "", "", "0", "", "", "", "", "1", "7.41", "0.074", "0.0025", "1.32349", "", "", "", "", "", "1", "0", "", "0035", "", "", "", "", "", "", "", "", "90.0", "98.6", "", "", "", "", "96.9"]} -{"pcdb_id": 17991, "brand_name": "Ideal", "model_name": "INDEPENDENT COMBI", "model_qualifier": "24", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 69.8, "output_kw_max": 24.2, "final_year_of_manufacture": null, "raw": ["017991", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "INDEPENDENT COMBI", "24", "47-349-24", "2016", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "89.0", "87.3", "", "69.8", "", "2", "", "", "104", "1", "2", "29", "5", "0", "", "", "", "0", "", "", "", "", "1", "7.549", "0.076", "0.0026", "1.45745", "", "", "", "", "", "1", "0", "", "0025", "", "", "", "", "", "", "", "", "90.0", "98.6", "", "", "", "", "96.9"]} -{"pcdb_id": 17992, "brand_name": "Ideal", "model_name": "INDEPENDENT COMBI", "model_qualifier": "30", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 70.4, "output_kw_max": 24.2, "final_year_of_manufacture": null, "raw": ["017992", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "INDEPENDENT COMBI", "30", "47-349-25", "2016", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "89.0", "87.3", "", "70.4", "", "2", "", "", "104", "1", "2", "31", "5", "0", "", "", "", "0", "", "", "", "", "1", "7.476", "0.075", "0.0026", "1.38721", "", "", "", "", "", "1", "0", "", "0025", "", "", "", "", "", "", "", "", "90.0", "98.6", "", "", "", "", "96.9"]} -{"pcdb_id": 17993, "brand_name": "Ideal", "model_name": "INDEPENDENT COMBI", "model_qualifier": "35", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 71.1, "output_kw_max": 24.2, "final_year_of_manufacture": null, "raw": ["017993", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "INDEPENDENT COMBI", "35", "47-349-26", "2016", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "89.0", "87.3", "", "71.1", "", "2", "", "", "104", "1", "2", "42", "5", "0", "", "", "", "0", "", "", "", "", "1", "7.41", "0.074", "0.0025", "1.32349", "", "", "", "", "", "1", "0", "", "0025", "", "", "", "", "", "", "", "", "90.0", "98.6", "", "", "", "", "96.9"]} -{"pcdb_id": 17994, "brand_name": "Ideal", "model_name": "INDEPENDENT + COMBI", "model_qualifier": "24", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 69.8, "output_kw_max": 24.2, "final_year_of_manufacture": null, "raw": ["017994", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "INDEPENDENT + COMBI", "24", "47-349-27", "2016", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "89.0", "87.3", "", "69.8", "", "2", "", "", "104", "1", "2", "29", "5", "0", "", "", "", "0", "", "", "", "", "1", "7.549", "0.076", "0.0026", "1.45745", "", "", "", "", "", "1", "0", "", "0025", "", "", "", "", "", "", "", "", "90.0", "98.6", "", "", "", "", "96.9"]} -{"pcdb_id": 17995, "brand_name": "Ideal", "model_name": "INDEPENDENT + COMBI", "model_qualifier": "30", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 70.4, "output_kw_max": 24.2, "final_year_of_manufacture": null, "raw": ["017995", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "INDEPENDENT + COMBI", "30", "47-349-28", "2016", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "89.0", "87.3", "", "70.4", "", "2", "", "", "104", "1", "2", "31", "5", "0", "", "", "", "0", "", "", "", "", "1", "7.476", "0.075", "0.0026", "1.38721", "", "", "", "", "", "1", "0", "", "0025", "", "", "", "", "", "", "", "", "90.0", "98.6", "", "", "", "", "96.9"]} -{"pcdb_id": 17996, "brand_name": "Ideal", "model_name": "INDEPENDENT + COMBI", "model_qualifier": "35", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 71.1, "output_kw_max": 24.2, "final_year_of_manufacture": null, "raw": ["017996", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "INDEPENDENT + COMBI", "35", "47-349-29", "2016", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "89.0", "87.3", "", "71.1", "", "2", "", "", "104", "1", "2", "42", "5", "0", "", "", "", "0", "", "", "", "", "1", "7.41", "0.074", "0.0025", "1.32349", "", "", "", "", "", "1", "0", "", "0025", "", "", "", "", "", "", "", "", "90.0", "98.6", "", "", "", "", "96.9"]} -{"pcdb_id": 17997, "brand_name": "i-mini", "model_name": "C24", "model_qualifier": "", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 69.8, "output_kw_max": 24.2, "final_year_of_manufacture": null, "raw": ["017997", "000008", "0", "2016/Nov/14 12:38", "Ideal Boilers", "i-mini", "C24", "", "47-349-30", "2016", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "89.0", "87.3", "", "69.8", "", "2", "", "", "104", "1", "2", "29", "5", "0", "", "", "", "0", "", "", "", "", "1", "7.549", "0.076", "0.0026", "1.45745", "", "", "", "", "", "1", "0", "", "0025", "", "", "", "", "", "", "", "", "90.0", "98.6", "", "", "", "", "96.9"]} -{"pcdb_id": 17998, "brand_name": "i-mini", "model_name": "C30", "model_qualifier": "", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 70.4, "output_kw_max": 24.2, "final_year_of_manufacture": null, "raw": ["017998", "000008", "0", "2016/Nov/14 12:38", "Ideal Boilers", "i-mini", "C30", "", "47-349-31", "2016", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "89.0", "87.3", "", "70.4", "", "2", "", "", "104", "1", "2", "31", "5", "0", "", "", "0", "0", "", "", "", "", "1", "7.476", "0.075", "0.0026", "1.38721", "", "", "", "", "", "1", "0", "", "0025", "", "", "", "", "", "", "", "", "90.0", "98.6", "", "", "", "", "96.9"]} -{"pcdb_id": 17999, "brand_name": "Glow-worm", "model_name": "EASICOM 3 25r", "model_qualifier": "", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 25.2, "final_year_of_manufacture": null, "raw": ["017999", "000207", "0", "2019/May/09 11:49", "Glow-worm", "Glow-worm", "EASICOM 3 25r", "", "41-019-50", "2016", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "25.2", "25.2", "", "", "89.0", "80.0", "", "58.4", "", "2", "", "", "102", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0085", "", "", "", "", "", "", "", "", "89.0", "98.8", "", "", "", "", "97.0"]} -{"pcdb_id": 18000, "brand_name": "Glow-worm", "model_name": "EASICOM 3 25s", "model_qualifier": "", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 25.2, "final_year_of_manufacture": null, "raw": ["018000", "000207", "0", "2019/May/09 11:53", "Glow-worm", "Glow-worm", "EASICOM 3 25s", "", "41-019-49", "2016", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "25.2", "25.2", "", "", "89.0", "80.0", "", "58.4", "", "2", "", "", "102", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0085", "", "", "", "", "", "", "", "", "89.2", "98.8", "", "", "", "", "97.0"]} -{"pcdb_id": 18001, "brand_name": "Glow-worm", "model_name": "PROCOMBI ESSENTIAL", "model_qualifier": "24c P - A (H-GB)", "winter_efficiency_pct": 90.5, "summer_efficiency_pct": 81.9, "comparative_hot_water_efficiency_pct": 57.6, "output_kw_max": 24.2, "final_year_of_manufacture": null, "raw": ["018001", "000207", "0", "2017/Jun/12 09:17", "Glow-worm", "Glow-worm", "PROCOMBI ESSENTIAL", "24c P - A (H-GB)", "47-019-46", "2016", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "90.5", "81.9", "", "57.6", "", "2", "0", "", "104", "1", "2", "", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.4", "100.2", "", "", "", "", "98.3"]} -{"pcdb_id": 18002, "brand_name": "Glow-worm", "model_name": "PROCOMBI ESSENTIAL 35c", "model_qualifier": "", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 56.6, "output_kw_max": 35.0, "final_year_of_manufacture": null, "raw": ["018002", "000207", "0", "2017/Jul/17 09:58", "Glow-worm", "Glow-worm", "PROCOMBI ESSENTIAL 35c", "", "47-019-49", "2016", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "35.0", "35.0", "", "", "89.1", "80.5", "", "56.6", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.5", "99.0", "", "", "", "", "97.2"]} -{"pcdb_id": 18004, "brand_name": "Sime", "model_name": "MURELLE ADVANCED HE 30 MkII", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 86.8, "comparative_hot_water_efficiency_pct": 69.0, "output_kw_max": 23.6, "final_year_of_manufacture": null, "raw": ["018004", "000213", "0", "2016/Nov/02 16:28", "Fonderie Sime S.p.A.", "Sime", "MURELLE ADVANCED HE 30 MkII", "", "47-283-82", "2017", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "23.6", "23.6", "", "", "88.4", "86.8", "", "69.0", "", "2", "", "", "104", "1", "2", "44", "3", "0", "", "", "", "0", "", "", "", "", "1", "7.63", "0.118", "0.0058", "1.47541", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.5", "97.7", "", "", "", "", "95.9"]} -{"pcdb_id": 18005, "brand_name": "Sime", "model_name": "MURELLE ADVANCED HE 40 MkII", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 86.9, "comparative_hot_water_efficiency_pct": 65.8, "output_kw_max": 34.5, "final_year_of_manufacture": null, "raw": ["018005", "000213", "0", "2016/Nov/02 16:28", "Fonderie Sime S.p.A.", "Sime", "MURELLE ADVANCED HE 40 MkII", "", "47-283-83", "2017", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "34.5", "34.5", "", "", "88.5", "86.9", "", "65.8", "", "2", "", "", "104", "1", "2", "66", "3", "0", "", "", "", "0", "", "", "", "", "1", "7.998", "0.108", "0.0056", "1.83882", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.7", "97.7", "", "", "", "", "96.0"]} -{"pcdb_id": 18006, "brand_name": "Sime", "model_name": "MURELLE PRO HE 30 MkII", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 86.8, "comparative_hot_water_efficiency_pct": 73.2, "output_kw_max": 23.6, "final_year_of_manufacture": 2019, "raw": ["018006", "000213", "0", "2019/Feb/28 13:17", "Fonderie Sime S.p.A.", "Sime", "MURELLE PRO HE 30 MkII", "", "47-283-81", "2017", "2019", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "23.6", "23.6", "", "", "88.4", "86.8", "", "73.2", "", "2", "", "", "104", "1", "2", "44", "3", "0", "", "", "", "0", "", "", "", "", "1", "7.19", "0.115", "0.0051", "1.05541", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.5", "97.7", "", "", "", "", "95.9"]} -{"pcdb_id": 18007, "brand_name": "Sime", "model_name": "MURELLE PRO HE 20 R MkII", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 19.7, "final_year_of_manufacture": null, "raw": ["018007", "000213", "0", "2016/Nov/02 16:27", "Fonderie Sime S.p.A.", "Sime", "MURELLE PRO HE 20 R MkII", "", "41-283-61", "2017", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "19.7", "19.7", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "24", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.5", "97.7", "", "", "", "", "95.9"]} -{"pcdb_id": 18008, "brand_name": "Sime", "model_name": "MURELLE PRO HE 30 R MkII", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 29.5, "final_year_of_manufacture": null, "raw": ["018008", "000213", "0", "2016/Nov/02 16:29", "Fonderie Sime S.p.A.", "Sime", "MURELLE PRO HE 30 R MkII", "", "41-283-62", "2017", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "29.5", "29.5", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "37", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.5", "97.7", "", "", "", "", "95.9"]} -{"pcdb_id": 18009, "brand_name": "Sime", "model_name": "MURELLE PRO HE 25 HO MkII", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 23.6, "final_year_of_manufacture": null, "raw": ["018009", "000213", "0", "2016/Nov/02 16:30", "Fonderie Sime S.p.A.", "Sime", "MURELLE PRO HE 25 HO MkII", "", "41-283-63", "2017", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "23.6", "23.6", "", "", "88.5", "79.5", "", "58.0", "", "2", "", "", "102", "1", "2", "34", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.7", "97.7", "", "", "", "", "96.0"]} -{"pcdb_id": 18011, "brand_name": "Firebird", "model_name": "Enviromax Slimline Combi", "model_qualifier": "20", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 82.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 20.0, "final_year_of_manufacture": null, "raw": ["018011", "000047", "0", "2017/Jan/25 15:41", "Firebird Heating Solutions Ltd", "Firebird", "Enviromax Slimline Combi", "20", "", "2009", "current", "4", "1", "1", "2", "0", "", "", "2", "2", "2", "20.0", "20.0", "", "", "89.4", "82.0", "", "57.7", "", "2", "", "", "202", "1", "1", "", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "93.1", "97.4", "", "", "", "", "96.6"]} -{"pcdb_id": 18012, "brand_name": "Firebird", "model_name": "Enviromax Slimline Combi", "model_qualifier": "26", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 82.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 26.0, "final_year_of_manufacture": null, "raw": ["018012", "000047", "0", "2017/Jan/25 15:42", "Firebird Heating Solutions Ltd", "Firebird", "Enviromax Slimline Combi", "26", "", "2009", "current", "4", "1", "1", "2", "0", "", "", "2", "2", "2", "26.0", "26.0", "", "", "89.4", "82.0", "", "57.7", "", "2", "", "", "202", "1", "1", "", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "93.0", "97.5", "", "", "", "", "96.7"]} -{"pcdb_id": 18013, "brand_name": "Viessmann", "model_name": "VITODENS 200-W", "model_qualifier": "B2HB-19", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 17.6, "final_year_of_manufacture": null, "raw": ["018013", "000033", "0", "2017/Jul/17 11:21", "Viessmann", "Viessmann", "VITODENS 200-W", "B2HB-19", "", "2016", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "17.6", "17.6", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "16", "4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "2005", "", "", "", "", "", "", "", "", "87.8", "97.8", "", "", "", "", "95.9"]} -{"pcdb_id": 18014, "brand_name": "Viessmann", "model_name": "VITODENS 200-W", "model_qualifier": "B2HB-26", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 24.1, "final_year_of_manufacture": null, "raw": ["018014", "000033", "0", "2017/Jul/26 09:04", "Viessmann", "Viessmann", "VITODENS 200-W", "B2HB-26", "", "2016", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24.1", "24.1", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "18", "4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "2005", "", "", "", "", "", "", "", "", "88.3", "97.8", "", "", "", "", "96.0"]} -{"pcdb_id": 18015, "brand_name": "Viessmann", "model_name": "VITODENS 200-W", "model_qualifier": "B2HB-30", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 28.0, "final_year_of_manufacture": null, "raw": ["018015", "000033", "0", "2017/Jul/17 11:22", "Viessmann", "Viessmann", "VITODENS 200-W", "B2HB-30", "", "2016", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "28.0", "28.0", "", "", "88.5", "79.5", "", "58.0", "", "2", "", "", "102", "1", "2", "20", "4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "2005", "", "", "", "", "", "", "", "", "88.3", "97.8", "", "", "", "", "96.0"]} -{"pcdb_id": 18016, "brand_name": "Viessmann", "model_name": "VITODENS 200-W", "model_qualifier": "B2HB-35", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 32.5, "final_year_of_manufacture": null, "raw": ["018016", "000033", "0", "2017/Jul/17 11:22", "Viessmann", "Viessmann", "VITODENS 200-W", "B2HB-35", "", "2016", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "32.5", "32.5", "", "", "88.5", "79.5", "", "58.1", "", "2", "", "", "102", "1", "2", "22", "4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "2005", "", "", "", "", "", "", "", "", "88.0", "98.0", "", "", "", "", "96.1"]} -{"pcdb_id": 18017, "brand_name": "Viessmann", "model_name": "VITODENS 200-W", "model_qualifier": "B2KB-26", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 56.1, "output_kw_max": 24.1, "final_year_of_manufacture": null, "raw": ["018017", "000033", "0", "2017/Jul/17 11:22", "Viessmann", "Viessmann", "VITODENS 200-W", "B2KB-26", "", "2016", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.1", "24.1", "", "", "88.4", "79.8", "", "56.1", "", "2", "", "", "104", "1", "2", "18", "4", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "2005", "", "", "", "", "", "", "", "", "88.3", "97.8", "", "", "", "", "96.0"]} -{"pcdb_id": 18019, "brand_name": "Viessmann", "model_name": "VITODENS 200-W", "model_qualifier": "B2KB-30", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 56.2, "output_kw_max": 28.0, "final_year_of_manufacture": null, "raw": ["018019", "000033", "0", "2017/Jul/17 11:22", "Viessmann", "Viessmann", "VITODENS 200-W", "B2KB-30", "", "2016", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28.0", "28.0", "", "", "88.4", "79.8", "", "56.2", "", "2", "", "", "104", "1", "2", "20", "4", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "2005", "", "", "", "", "", "", "", "", "88.2", "97.8", "", "", "", "", "96.0"]} -{"pcdb_id": 18020, "brand_name": "Viessmann", "model_name": "VITODENS 200-W", "model_qualifier": "B2KB-35", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 56.2, "output_kw_max": 32.5, "final_year_of_manufacture": null, "raw": ["018020", "000033", "0", "2017/Jul/17 11:23", "Viessmann", "Viessmann", "VITODENS 200-W", "B2KB-35", "", "2016", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "32.5", "32.5", "", "", "88.5", "79.9", "", "56.2", "", "2", "", "", "104", "1", "2", "22", "4", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "2005", "", "", "", "", "", "", "", "", "88.0", "98.0", "", "", "", "", "96.1"]} -{"pcdb_id": 18027, "brand_name": "Ideal", "model_name": "INDEPENDENT SYSTEM", "model_qualifier": "s15", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 15.0, "final_year_of_manufacture": null, "raw": ["018027", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "INDEPENDENT SYSTEM", "s15", "41-750-69", "2016", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "15.0", "15.0", "", "", "88.7", "79.7", "", "58.2", "", "2", "", "", "102", "1", "2", "48", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "90.0", "97.8", "", "", "", "", "96.4"]} -{"pcdb_id": 18028, "brand_name": "Ideal", "model_name": "INDEPENDENT SYSTEM", "model_qualifier": "s18", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 18.0, "final_year_of_manufacture": null, "raw": ["018028", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "INDEPENDENT SYSTEM", "s18", "41-750-70", "2016", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18.0", "18.0", "", "", "88.9", "79.9", "", "58.4", "", "2", "", "", "102", "1", "2", "26", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "89.7", "98.5", "", "", "", "", "96.8"]} -{"pcdb_id": 18029, "brand_name": "Ideal", "model_name": "INDEPENDENT SYSTEM", "model_qualifier": "s24", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 24.2, "final_year_of_manufacture": null, "raw": ["018029", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "INDEPENDENT SYSTEM", "s24", "41-750-71", "2016", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "89.1", "80.1", "", "58.5", "", "2", "", "", "102", "1", "2", "42", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "90.0", "98.7", "", "", "", "", "97.0"]} -{"pcdb_id": 18030, "brand_name": "Ideal", "model_name": "INDEPENDENT SYSTEM", "model_qualifier": "s30", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 30.3, "final_year_of_manufacture": null, "raw": ["018030", "000008", "0", "2017/May/15 15:31", "Ideal Boilers", "Ideal", "INDEPENDENT SYSTEM", "s30", "41-750-72", "2016", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "30.3", "30.3", "", "", "88.8", "79.8", "", "58.3", "", "2", "", "", "102", "1", "2", "48", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "89.6", "98.2", "", "", "", "", "96.6"]} -{"pcdb_id": 18031, "brand_name": "Ideal", "model_name": "LOGIC+ HEAT", "model_qualifier": "H12", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 12.0, "final_year_of_manufacture": null, "raw": ["018031", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "LOGIC+ HEAT", "H12", "41-750-82", "2016", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "12.0", "12.0", "", "", "88.7", "79.7", "", "58.2", "", "2", "", "", "102", "1", "2", "20", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "89.9", "97.7", "", "", "", "", "96.2"]} -{"pcdb_id": 18032, "brand_name": "Ideal", "model_name": "LOGIC+ HEAT", "model_qualifier": "H15", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 15.0, "final_year_of_manufacture": null, "raw": ["018032", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "LOGIC+ HEAT", "H15", "41-750-83", "2016", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "15.0", "15.0", "", "", "88.7", "79.7", "", "58.2", "", "2", "", "", "102", "1", "2", "26", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "90.0", "97.8", "", "", "", "", "96.3"]} -{"pcdb_id": 18033, "brand_name": "Ideal", "model_name": "LOGIC+ HEAT", "model_qualifier": "H18", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 18.0, "final_year_of_manufacture": null, "raw": ["018033", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "LOGIC+ HEAT", "H18", "41-750-84", "2016", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18.0", "18.0", "", "", "88.9", "79.9", "", "58.4", "", "2", "", "", "102", "1", "2", "26", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "89.7", "98.5", "", "", "", "", "96.8"]} -{"pcdb_id": 18034, "brand_name": "Ideal", "model_name": "LOGIC+ HEAT", "model_qualifier": "H24", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 24.2, "final_year_of_manufacture": null, "raw": ["018034", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "LOGIC+ HEAT", "H24", "41-750-85", "2016", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "89.1", "80.1", "", "58.5", "", "2", "", "", "102", "1", "2", "48", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "90.0", "98.7", "", "", "", "", "97.0"]} -{"pcdb_id": 18035, "brand_name": "Ideal", "model_name": "LOGIC+ HEAT", "model_qualifier": "H30", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 30.3, "final_year_of_manufacture": null, "raw": ["018035", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "LOGIC+ HEAT", "H30", "41-750-86", "2016", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "30.3", "30.3", "", "", "88.8", "79.8", "", "58.3", "", "2", "", "", "102", "1", "2", "48", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "89.6", "98.2", "", "", "", "", "96.6"]} -{"pcdb_id": 18036, "brand_name": "Ideal", "model_name": "LOGIC+ SYSTEM", "model_qualifier": "s15", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 15.0, "final_year_of_manufacture": null, "raw": ["018036", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "LOGIC+ SYSTEM", "s15", "41-750-85", "2016", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "15.0", "15.0", "", "", "88.7", "79.7", "", "58.2", "", "2", "", "", "102", "1", "2", "21", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "90.0", "97.8", "", "", "", "", "96.3"]} -{"pcdb_id": 18037, "brand_name": "Ideal", "model_name": "LOGIC+ SYSTEM", "model_qualifier": "s18", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 18.0, "final_year_of_manufacture": null, "raw": ["018037", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "LOGIC+ SYSTEM", "s18", "41-750-66", "2016", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18.0", "18.0", "", "", "88.9", "79.9", "", "58.4", "", "2", "", "", "102", "1", "2", "26", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "89.7", "98.5", "", "", "", "", "96.8"]} -{"pcdb_id": 18038, "brand_name": "Ideal", "model_name": "LOGIC+ SYSTEM", "model_qualifier": "s24", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 24.2, "final_year_of_manufacture": null, "raw": ["018038", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "LOGIC+ SYSTEM", "s24", "41-750-67", "2016", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "89.1", "80.1", "", "58.5", "", "2", "", "", "102", "1", "2", "42", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "90.0", "98.7", "", "", "", "", "97.0"]} -{"pcdb_id": 18039, "brand_name": "Ideal", "model_name": "LOGIC+ SYSTEM", "model_qualifier": "s30", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 30.3, "final_year_of_manufacture": null, "raw": ["018039", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "LOGIC+ SYSTEM", "s30", "41-750-68", "2016", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "30.3", "30.3", "", "", "88.8", "79.8", "", "58.3", "", "2", "", "", "102", "1", "2", "48", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "89.6", "98.2", "", "", "", "", "96.6"]} -{"pcdb_id": 18040, "brand_name": "Ideal", "model_name": "LOGIC HEAT", "model_qualifier": "H12", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 12.0, "final_year_of_manufacture": null, "raw": ["018040", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "LOGIC HEAT", "H12", "41-750-77", "2016", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "12.0", "12.0", "", "", "88.7", "79.7", "", "58.2", "", "2", "", "", "102", "1", "2", "20", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "89.9", "97.7", "", "", "", "", "96.2"]} -{"pcdb_id": 18041, "brand_name": "Ideal", "model_name": "LOGIC HEAT", "model_qualifier": "H15", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 15.0, "final_year_of_manufacture": null, "raw": ["018041", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "LOGIC HEAT", "H15", "41-750-78", "2016", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "15.0", "15.0", "", "", "88.7", "79.7", "", "58.2", "", "2", "", "", "102", "1", "2", "21", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "90.0", "97.8", "", "", "", "", "96.3"]} -{"pcdb_id": 18042, "brand_name": "Ideal", "model_name": "LOGIC HEAT", "model_qualifier": "H18", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 18.0, "final_year_of_manufacture": null, "raw": ["018042", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "LOGIC HEAT", "H18", "41-750-79", "2016", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18.0", "18.0", "", "", "88.9", "79.9", "", "58.4", "", "2", "", "", "102", "1", "2", "26", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "89.7", "98.5", "", "", "", "", "96.8"]} -{"pcdb_id": 18043, "brand_name": "Ideal", "model_name": "LOGIC HEAT", "model_qualifier": "H24", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 24.2, "final_year_of_manufacture": null, "raw": ["018043", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "LOGIC HEAT", "H24", "41-750-80", "2016", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "89.1", "80.1", "", "58.5", "", "2", "", "", "102", "1", "2", "42", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "90.0", "98.7", "", "", "", "", "97.0"]} -{"pcdb_id": 18044, "brand_name": "Ideal", "model_name": "LOGIC HEAT", "model_qualifier": "H30", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 30.3, "final_year_of_manufacture": null, "raw": ["018044", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "LOGIC HEAT", "H30", "41-750-81", "2016", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "30.3", "30.3", "", "", "88.8", "79.8", "", "58.3", "", "2", "", "", "102", "1", "2", "48", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "89.6", "98.2", "", "", "", "", "96.6"]} -{"pcdb_id": 18045, "brand_name": "Ideal", "model_name": "LOGIC SYSTEM", "model_qualifier": "s15", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 15.0, "final_year_of_manufacture": null, "raw": ["018045", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "LOGIC SYSTEM", "s15", "41-750-61", "2016", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "15.0", "15.0", "", "", "88.7", "79.7", "", "58.2", "", "2", "", "", "102", "1", "2", "21", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "90.0", "97.8", "", "", "", "", "96.3"]} -{"pcdb_id": 18046, "brand_name": "Ideal", "model_name": "LOGIC SYSTEM", "model_qualifier": "s15IE", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 15.0, "final_year_of_manufacture": null, "raw": ["018046", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "LOGIC SYSTEM", "s15IE", "41-750-73", "2016", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "15.0", "15.0", "", "", "88.7", "79.7", "", "58.2", "", "2", "", "", "102", "1", "2", "21", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "90.0", "97.8", "", "", "", "", "96.3"]} -{"pcdb_id": 18047, "brand_name": "Ideal", "model_name": "LOGIC SYSTEM", "model_qualifier": "s18", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 18.0, "final_year_of_manufacture": null, "raw": ["018047", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "LOGIC SYSTEM", "s18", "41-750-62", "2016", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18.0", "18.0", "", "", "88.9", "79.9", "", "58.4", "", "2", "", "", "102", "1", "2", "26", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "89.7", "98.5", "", "", "", "", "96.8"]} -{"pcdb_id": 18048, "brand_name": "Ideal", "model_name": "LOGIC SYSTEM", "model_qualifier": "s18IE", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 18.0, "final_year_of_manufacture": null, "raw": ["018048", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "LOGIC SYSTEM", "s18IE", "41-750-74", "2016", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18.0", "18.0", "", "", "88.9", "79.9", "", "58.4", "", "2", "", "", "102", "1", "2", "26", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "89.7", "98.5", "", "", "", "", "96.8"]} -{"pcdb_id": 18049, "brand_name": "Ideal", "model_name": "LOGIC SYSTEM", "model_qualifier": "s24", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 24.2, "final_year_of_manufacture": null, "raw": ["018049", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "LOGIC SYSTEM", "s24", "41-750-63", "2016", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "89.1", "80.1", "", "58.5", "", "2", "", "", "102", "1", "2", "42", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "90.0", "98.7", "", "", "", "", "97.0"]} -{"pcdb_id": 18050, "brand_name": "Ideal", "model_name": "LOGIC SYSTEM", "model_qualifier": "s24IE", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 24.2, "final_year_of_manufacture": null, "raw": ["018050", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "LOGIC SYSTEM", "s24IE", "41-750-75", "2016", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "89.1", "80.1", "", "58.5", "", "2", "", "", "102", "1", "2", "42", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "90.0", "98.7", "", "", "", "", "97.0"]} -{"pcdb_id": 18051, "brand_name": "Ideal", "model_name": "LOGIC SYSTEM", "model_qualifier": "s30", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 30.3, "final_year_of_manufacture": null, "raw": ["018051", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "LOGIC SYSTEM", "s30", "41-750-64", "2016", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "30.3", "30.3", "", "", "88.8", "79.8", "", "58.3", "", "2", "", "", "102", "1", "2", "48", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "89.6", "98.2", "", "", "", "", "96.6"]} -{"pcdb_id": 18052, "brand_name": "Ideal", "model_name": "LOGIC SYSTEM", "model_qualifier": "s30IE", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 30.3, "final_year_of_manufacture": null, "raw": ["018052", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "LOGIC SYSTEM", "s30IE", "41-750-76", "2016", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "30.3", "30.3", "", "", "88.8", "79.8", "", "58.3", "", "2", "", "", "102", "1", "2", "48", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "89.6", "98.2", "", "", "", "", "96.6"]} -{"pcdb_id": 18053, "brand_name": "Keston", "model_name": "KESTON SYSTEM S30", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 30.3, "final_year_of_manufacture": null, "raw": ["018053", "000022", "0", "2017/May/15 15:31", "Keston Boilers", "Keston", "KESTON SYSTEM S30", "", "41-930-45", "2016", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "30.3", "30.3", "", "", "88.8", "79.8", "", "58.3", "", "2", "", "", "102", "1", "2", "48", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "", "", "", "", "89.6", "98.2", "", "", "", "", "96.6"]} -{"pcdb_id": 18054, "brand_name": "Ideal", "model_name": "INDEPENDENT + COMBI 30P", "model_qualifier": "", "winter_efficiency_pct": 90.1, "summer_efficiency_pct": 81.5, "comparative_hot_water_efficiency_pct": 57.3, "output_kw_max": 24.2, "final_year_of_manufacture": null, "raw": ["018054", "000008", "0", "2017/Jan/23 13:46", "Ideal Boilers", "Ideal", "INDEPENDENT + COMBI 30P", "", "47-349-28", "2016", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "90.1", "81.5", "", "57.3", "", "2", "1", "", "104", "1", "2", "31", "5", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "", "", "", "", "92.0", "100.8", "", "", "", "", "99.2"]} -{"pcdb_id": 18055, "brand_name": "Ideal", "model_name": "INDEPENDENT COMBI", "model_qualifier": "30P", "winter_efficiency_pct": 90.1, "summer_efficiency_pct": 81.5, "comparative_hot_water_efficiency_pct": 57.3, "output_kw_max": 24.2, "final_year_of_manufacture": null, "raw": ["018055", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "INDEPENDENT COMBI", "30P", "47-349-25", "2016", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "90.1", "81.5", "", "57.3", "", "2", "1", "", "104", "1", "2", "31", "5", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "", "", "", "", "92.0", "100.8", "", "", "", "", "99.2"]} -{"pcdb_id": 18056, "brand_name": "Ideal", "model_name": "INDEPENDENT SYSTEM S30P", "model_qualifier": "", "winter_efficiency_pct": 89.8, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 59.1, "output_kw_max": 30.3, "final_year_of_manufacture": null, "raw": ["018056", "000008", "0", "2017/May/15 15:31", "Ideal Boilers", "Ideal", "INDEPENDENT SYSTEM S30P", "", "41-750-72", "2016", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "30.3", "30.3", "", "", "89.8", "80.8", "", "59.1", "", "2", "1", "", "102", "1", "2", "48", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0015", "", "", "", "", "", "", "", "", "91.6", "100.4", "", "", "", "", "98.7"]} -{"pcdb_id": 18057, "brand_name": "Ideal", "model_name": "LOGIC + COMBI C30P", "model_qualifier": "", "winter_efficiency_pct": 90.1, "summer_efficiency_pct": 81.5, "comparative_hot_water_efficiency_pct": 57.3, "output_kw_max": 24.2, "final_year_of_manufacture": null, "raw": ["018057", "000008", "0", "2017/Jan/23 13:46", "Ideal Boilers", "Ideal", "LOGIC + COMBI C30P", "", "47-349-16", "2016", "current", "2", "1", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "90.1", "81.5", "", "57.3", "", "2", "1", "", "104", "1", "2", "31", "5", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "", "", "", "", "92.0", "100.8", "", "", "", "", "99.2"]} -{"pcdb_id": 18058, "brand_name": "Ideal", "model_name": "LOGIC + HEAT H30P", "model_qualifier": "", "winter_efficiency_pct": 89.8, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 59.1, "output_kw_max": 30.3, "final_year_of_manufacture": null, "raw": ["018058", "000008", "0", "2017/May/15 15:31", "Ideal Boilers", "Ideal", "LOGIC + HEAT H30P", "", "41-750-86", "2016", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "30.3", "30.3", "", "", "89.8", "80.8", "", "59.1", "", "2", "1", "", "102", "1", "2", "48", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0015", "", "", "", "", "", "", "", "", "91.6", "100.4", "", "", "", "", "98.7"]} -{"pcdb_id": 18059, "brand_name": "Ideal", "model_name": "LOGIC + SYSTEM S30P", "model_qualifier": "", "winter_efficiency_pct": 89.8, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 59.1, "output_kw_max": 30.3, "final_year_of_manufacture": null, "raw": ["018059", "000008", "0", "2017/May/15 15:31", "Ideal Boilers", "Ideal", "LOGIC + SYSTEM S30P", "", "41-750-68", "2016", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "30.3", "30.3", "", "", "89.8", "80.8", "", "59.1", "", "2", "1", "", "102", "1", "2", "48", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0015", "", "", "", "", "", "", "", "", "91.6", "100.4", "", "", "", "", "98.7"]} -{"pcdb_id": 18060, "brand_name": "Ideal", "model_name": "LOGIC COMBI", "model_qualifier": "ESP1 35P", "winter_efficiency_pct": 90.1, "summer_efficiency_pct": 81.5, "comparative_hot_water_efficiency_pct": 57.3, "output_kw_max": 24.2, "final_year_of_manufacture": null, "raw": ["018060", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "LOGIC COMBI", "ESP1 35P", "47-349-23", "2016", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "90.1", "81.5", "", "57.3", "", "2", "1", "", "104", "1", "2", "42", "5", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "", "", "", "", "92.0", "100.8", "", "", "", "", "99.2"]} -{"pcdb_id": 18061, "brand_name": "Ideal", "model_name": "LOGIC HEAT H30P", "model_qualifier": "", "winter_efficiency_pct": 89.8, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 59.1, "output_kw_max": 30.3, "final_year_of_manufacture": null, "raw": ["018061", "000008", "0", "2017/May/15 15:31", "Ideal Boilers", "Ideal", "LOGIC HEAT H30P", "", "41-750-81", "2016", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "30.3", "30.3", "", "", "89.8", "80.8", "", "59.1", "", "2", "1", "", "102", "1", "2", "48", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0015", "", "", "", "", "", "", "", "", "91.6", "100.4", "", "", "", "", "98.7"]} -{"pcdb_id": 18062, "brand_name": "Ideal", "model_name": "LOGIC SYSTEM S24P IE", "model_qualifier": "", "winter_efficiency_pct": 90.1, "summer_efficiency_pct": 81.1, "comparative_hot_water_efficiency_pct": 59.2, "output_kw_max": 24.2, "final_year_of_manufacture": null, "raw": ["018062", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "LOGIC SYSTEM S24P IE", "", "41-750-75", "2016", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "90.1", "81.1", "", "59.2", "", "2", "1", "", "102", "1", "2", "42", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "92.0", "100.8", "", "", "", "", "99.2"]} -{"pcdb_id": 18063, "brand_name": "Ideal", "model_name": "LOGIC SYSTEM S30P IE", "model_qualifier": "", "winter_efficiency_pct": 89.8, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 59.1, "output_kw_max": 30.3, "final_year_of_manufacture": null, "raw": ["018063", "000008", "0", "2017/May/15 15:31", "Ideal Boilers", "Ideal", "LOGIC SYSTEM S30P IE", "", "41-750-76", "2016", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "30.3", "30.3", "", "", "89.8", "80.8", "", "59.1", "", "2", "1", "", "102", "1", "2", "48", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0015", "", "", "", "", "", "", "", "", "91.6", "100.4", "", "", "", "", "98.7"]} -{"pcdb_id": 18064, "brand_name": "Ideal", "model_name": "LOGIC SYSTEM S30P", "model_qualifier": "", "winter_efficiency_pct": 89.8, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 59.1, "output_kw_max": 30.3, "final_year_of_manufacture": null, "raw": ["018064", "000008", "0", "2017/May/15 15:31", "Ideal Boilers", "Ideal", "LOGIC SYSTEM S30P", "", "41-750-64", "2016", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "30.3", "30.3", "", "", "89.8", "80.8", "", "59.1", "", "2", "1", "", "102", "1", "2", "48", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0015", "", "", "", "", "", "", "", "", "91.6", "100.4", "", "", "", "", "98.7"]} -{"pcdb_id": 18065, "brand_name": "Ideal", "model_name": "LOGIC COMBI C24P", "model_qualifier": "", "winter_efficiency_pct": 90.1, "summer_efficiency_pct": 81.5, "comparative_hot_water_efficiency_pct": 57.3, "output_kw_max": 24.2, "final_year_of_manufacture": null, "raw": ["018065", "000008", "0", "2017/Jan/23 13:46", "Ideal Boilers", "Ideal", "LOGIC COMBI C24P", "", "47-349-18", "2016", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "90.1", "81.5", "", "57.3", "", "2", "1", "", "104", "1", "2", "29", "5", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "", "", "", "", "92.0", "100.8", "", "", "", "", "99.2"]} -{"pcdb_id": 18066, "brand_name": "Ideal", "model_name": "LOGIC COMBI C30P", "model_qualifier": "", "winter_efficiency_pct": 90.1, "summer_efficiency_pct": 81.5, "comparative_hot_water_efficiency_pct": 57.3, "output_kw_max": 24.2, "final_year_of_manufacture": null, "raw": ["018066", "000008", "0", "2017/Jan/23 13:46", "Ideal Boilers", "Ideal", "LOGIC COMBI C30P", "", "47-349-19", "2016", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "90.1", "81.5", "", "57.3", "", "2", "1", "", "104", "1", "2", "31", "5", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "", "", "", "", "92.0", "100.8", "", "", "", "", "99.2"]} -{"pcdb_id": 18067, "brand_name": "Ideal", "model_name": "LOGIC COMBI", "model_qualifier": "ESP1 30P", "winter_efficiency_pct": 90.1, "summer_efficiency_pct": 81.5, "comparative_hot_water_efficiency_pct": 57.3, "output_kw_max": 24.2, "final_year_of_manufacture": null, "raw": ["018067", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "LOGIC COMBI", "ESP1 30P", "47-349-22", "2016", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "90.1", "81.5", "", "57.3", "", "2", "1", "", "104", "1", "2", "31", "5", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "", "", "", "", "92.0", "100.8", "", "", "", "", "99.2"]} -{"pcdb_id": 18068, "brand_name": "Ideal", "model_name": "LOGIC HEAT H24P", "model_qualifier": "", "winter_efficiency_pct": 90.1, "summer_efficiency_pct": 81.1, "comparative_hot_water_efficiency_pct": 59.2, "output_kw_max": 24.2, "final_year_of_manufacture": null, "raw": ["018068", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "LOGIC HEAT H24P", "", "41-750-80", "2016", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "90.1", "81.1", "", "59.2", "", "2", "1", "", "102", "1", "2", "42", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "92.0", "100.8", "", "", "", "", "99.2"]} -{"pcdb_id": 18069, "brand_name": "Keston", "model_name": "KESTON COMBI C30P", "model_qualifier": "", "winter_efficiency_pct": 90.1, "summer_efficiency_pct": 81.5, "comparative_hot_water_efficiency_pct": 57.3, "output_kw_max": 24.2, "final_year_of_manufacture": null, "raw": ["018069", "000022", "0", "2017/Jan/23 13:46", "Keston Boilers", "Keston", "KESTON COMBI C30P", "", "47-930-07", "2016", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "90.1", "81.5", "", "57.3", "", "2", "1", "", "104", "1", "2", "31", "5", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "", "", "", "", "92.0", "100.8", "", "", "", "", "99.2"]} -{"pcdb_id": 18070, "brand_name": "Keston", "model_name": "KESTON SYSTEM S30P", "model_qualifier": "", "winter_efficiency_pct": 89.8, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 59.1, "output_kw_max": 30.3, "final_year_of_manufacture": null, "raw": ["018070", "000022", "0", "2017/May/15 15:31", "Keston Boilers", "Keston", "KESTON SYSTEM S30P", "", "41-930-45", "2016", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "30.3", "30.3", "", "", "89.8", "80.8", "", "59.1", "", "2", "1", "", "102", "1", "2", "48", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "", "", "", "", "91.6", "100.4", "", "", "", "", "98.7"]} -{"pcdb_id": 18071, "brand_name": "Navien", "model_name": "NCB-20LHWE", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 19.5, "final_year_of_manufacture": null, "raw": ["018071", "000265", "0", "2020/Jun/02 09:22", "KD Navien", "Navien", "NCB-20LHWE", "", "41-709-01", "2014", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "19.5", "19.5", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "36", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "87.8", "97.8", "", "", "", "", "95.9"]} -{"pcdb_id": 18072, "brand_name": "Navien", "model_name": "NCB-23LHWE", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 23.4, "final_year_of_manufacture": null, "raw": ["018072", "000265", "0", "2020/Jun/02 09:39", "KD Navien", "Navien", "NCB-23LHWE", "", "41-709-02", "2014", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "23.4", "23.4", "", "", "88.5", "79.5", "", "58.1", "", "2", "", "", "102", "1", "2", "45", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "87.9", "98.1", "", "", "", "", "96.2"]} -{"pcdb_id": 18073, "brand_name": "Navien", "model_name": "NCB-28LHWE", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 28.3, "final_year_of_manufacture": null, "raw": ["018073", "000265", "0", "2020/Jun/02 09:46", "KD Navien", "Navien", "NCB-28LHWE", "", "41-709-03", "2014", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "28.3", "28.3", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "48", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "87.9", "97.8", "", "", "", "", "95.9"]} -{"pcdb_id": 18074, "brand_name": "Navien", "model_name": "NCB-33LHWE", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 33.2, "final_year_of_manufacture": null, "raw": ["018074", "000265", "0", "2020/Jun/02 10:03", "KD Navien", "Navien", "NCB-33LHWE", "", "41-709-04", "2014", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "33.2", "33.2", "", "", "88.5", "79.5", "", "58.0", "", "2", "", "", "102", "1", "2", "45", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "87.8", "98.0", "", "", "", "", "96.1"]} -{"pcdb_id": 18089, "brand_name": "Ideal", "model_name": "VOGUE", "model_qualifier": "C26 GEN2", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 76.2, "output_kw_max": 26.0, "final_year_of_manufacture": null, "raw": ["018089", "000008", "0", "2017/May/15 15:31", "Ideal Boilers", "Ideal", "VOGUE", "C26 GEN2", "47-349-38", "2017", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "26", "26", "", "", "88.6", "87.3", "", "76.2", "", "2", "", "", "104", "1", "2", "47", "3", "0", "", "", "", "0", "", "", "", "", "1", "6.915", "0.085", "0.001", "0.84569", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "", "", "", "", "89.7", "97.7", "", "", "", "", "96.2"]} -{"pcdb_id": 18090, "brand_name": "Ideal", "model_name": "VOGUE", "model_qualifier": "C32 GEN2", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 77.6, "output_kw_max": 32.0, "final_year_of_manufacture": null, "raw": ["018090", "000008", "0", "2017/May/15 15:31", "Ideal Boilers", "Ideal", "VOGUE", "C32 GEN2", "47-349-39", "2017", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "32", "32", "", "", "88.7", "87.3", "", "77.6", "", "2", "", "", "104", "1", "2", "63", "3", "0", "", "", "", "0", "", "", "", "", "1", "6.79", "0.087", "0.001", "0.72908", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "", "", "", "", "89.9", "97.8", "", "", "", "", "96.3"]} -{"pcdb_id": 18091, "brand_name": "Ideal", "model_name": "VOGUE", "model_qualifier": "C40 GEN2", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 77.2, "output_kw_max": 40.0, "final_year_of_manufacture": null, "raw": ["018091", "000008", "0", "2017/May/15 15:31", "Ideal Boilers", "Ideal", "VOGUE", "C40 GEN2", "47-349-40", "2017", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "40", "40", "", "", "88.6", "87.3", "", "77.2", "", "2", "", "", "104", "1", "2", "44", "3", "0", "", "", "", "0", "", "", "", "", "1", "6.821", "0.086", "0.001", "0.75466", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "", "", "", "", "89.7", "97.5", "", "", "", "", "96.0"]} -{"pcdb_id": 18092, "brand_name": "Ideal", "model_name": "VOGUE", "model_qualifier": "C26P GEN2", "winter_efficiency_pct": 89.6, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 57.0, "output_kw_max": 26.0, "final_year_of_manufacture": null, "raw": ["018092", "000008", "0", "2017/May/15 15:31", "Ideal Boilers", "Ideal", "VOGUE", "C26P GEN2", "47-349-38", "2017", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "26", "26", "", "", "89.6", "81.0", "", "57.0", "", "2", "1", "", "104", "1", "2", "47", "3", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0015", "", "", "", "", "", "", "", "", "91.7", "99.8", "", "", "", "", "98.3"]} -{"pcdb_id": 18093, "brand_name": "Ideal", "model_name": "VOGUE", "model_qualifier": "C32P GEN2", "winter_efficiency_pct": 89.7, "summer_efficiency_pct": 81.1, "comparative_hot_water_efficiency_pct": 57.1, "output_kw_max": 32.0, "final_year_of_manufacture": null, "raw": ["018093", "000008", "0", "2017/May/15 15:31", "Ideal Boilers", "Ideal", "VOGUE", "C32P GEN2", "47-349-39", "2017", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "32", "32", "", "", "89.7", "81.1", "", "57.1", "", "2", "1", "", "104", "1", "2", "63", "3", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0015", "", "", "", "", "", "", "", "", "91.9", "100.0", "", "", "", "", "98.5"]} -{"pcdb_id": 18094, "brand_name": "Ideal", "model_name": "VOGUE", "model_qualifier": "S15 GEN2", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 15.0, "final_year_of_manufacture": null, "raw": ["018094", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "VOGUE", "S15 GEN2", "41-750-86", "2017", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "15", "15", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "25", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "89.6", "97.0", "", "", "", "", "95.6"]} -{"pcdb_id": 18095, "brand_name": "Ideal", "model_name": "VOGUE", "model_qualifier": "S18 GEN2", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 18.0, "final_year_of_manufacture": null, "raw": ["018095", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "VOGUE", "S18 GEN2", "41-750-89", "2017", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18", "18", "", "", "88.7", "79.7", "", "58.2", "", "2", "", "", "102", "1", "2", "40", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "89.8", "97.8", "", "", "", "", "96.3"]} -{"pcdb_id": 18096, "brand_name": "Ideal", "model_name": "VOGUE", "model_qualifier": "S26 GEN2", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 26.0, "final_year_of_manufacture": null, "raw": ["018096", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "VOGUE", "S26 GEN2", "41-750-90", "2017", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "26", "26", "", "", "88.7", "79.7", "", "58.2", "", "2", "", "", "102", "1", "2", "45", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "89.7", "97.8", "", "", "", "", "96.2"]} -{"pcdb_id": 18097, "brand_name": "Ideal", "model_name": "VOGUE", "model_qualifier": "S32 GEN2", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 32.0, "final_year_of_manufacture": null, "raw": ["018097", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "VOGUE", "S32 GEN2", "41-750-91", "2017", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "32", "32", "", "", "88.7", "79.7", "", "58.2", "", "2", "", "", "102", "1", "2", "49", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "89.8", "97.8", "", "", "", "", "96.3"]} -{"pcdb_id": 18098, "brand_name": "Ideal", "model_name": "VOGUE", "model_qualifier": "S15P GEN2", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 80.4, "comparative_hot_water_efficiency_pct": 58.7, "output_kw_max": 15.0, "final_year_of_manufacture": null, "raw": ["018098", "000008", "0", "2017/May/15 15:31", "Ideal Boilers", "Ideal", "VOGUE", "S15P GEN2", "41-750-88", "2017", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "15", "15", "", "", "89.4", "80.4", "", "58.7", "", "2", "1", "", "102", "1", "2", "25", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0015", "", "", "", "", "", "", "", "", "91.5", "99.2", "", "", "", "", "97.7"]} -{"pcdb_id": 18099, "brand_name": "Ideal", "model_name": "VOGUE", "model_qualifier": "S18P GEN2", "winter_efficiency_pct": 89.7, "summer_efficiency_pct": 80.7, "comparative_hot_water_efficiency_pct": 59.0, "output_kw_max": 18.0, "final_year_of_manufacture": null, "raw": ["018099", "000008", "0", "2017/May/15 15:31", "Ideal Boilers", "Ideal", "VOGUE", "S18P GEN2", "41-750-89", "2017", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "18", "18", "", "", "89.7", "80.7", "", "59.0", "", "2", "1", "", "102", "1", "2", "40", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0015", "", "", "", "", "", "", "", "", "91.8", "100.0", "", "", "", "", "98.5"]} -{"pcdb_id": 18100, "brand_name": "Ideal", "model_name": "VOGUE", "model_qualifier": "S26P GEN2", "winter_efficiency_pct": 89.7, "summer_efficiency_pct": 80.7, "comparative_hot_water_efficiency_pct": 58.9, "output_kw_max": 26.0, "final_year_of_manufacture": null, "raw": ["018100", "000008", "0", "2017/May/15 15:31", "Ideal Boilers", "Ideal", "VOGUE", "S26P GEN2", "41-750-90", "2017", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "26", "26", "", "", "89.7", "80.7", "", "58.9", "", "2", "1", "", "102", "1", "2", "45", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0015", "", "", "", "", "", "", "", "", "91.7", "99.9", "", "", "", "", "98.4"]} -{"pcdb_id": 18101, "brand_name": "Ideal", "model_name": "VOGUE", "model_qualifier": "S32P GEN2", "winter_efficiency_pct": 89.7, "summer_efficiency_pct": 80.7, "comparative_hot_water_efficiency_pct": 59.0, "output_kw_max": 32.0, "final_year_of_manufacture": null, "raw": ["018101", "000008", "0", "2017/May/15 15:31", "Ideal Boilers", "Ideal", "VOGUE", "S32P GEN2", "41-750-91", "2017", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "32", "32", "", "", "89.7", "80.7", "", "59.0", "", "2", "1", "", "102", "1", "2", "49", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0015", "", "", "", "", "", "", "", "", "91.8", "100.0", "", "", "", "", "98.5"]} -{"pcdb_id": 18102, "brand_name": "Ideal", "model_name": "VOGUE", "model_qualifier": "C40P GEN2", "winter_efficiency_pct": 89.6, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 56.9, "output_kw_max": 40.0, "final_year_of_manufacture": null, "raw": ["018102", "000008", "0", "2017/May/15 15:31", "Ideal Boilers", "Ideal", "VOGUE", "C40P GEN2", "47-349-40", "2017", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "40", "40", "", "", "89.6", "81.0", "", "56.9", "", "2", "1", "", "104", "1", "2", "44", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0015", "", "", "", "", "", "", "", "", "91.7", "99.7", "", "", "", "", "98.1"]} -{"pcdb_id": 18103, "brand_name": "Sime", "model_name": "MURELLE ONE HE 25", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 87.0, "comparative_hot_water_efficiency_pct": 67.1, "output_kw_max": 20.0, "final_year_of_manufacture": null, "raw": ["018103", "000213", "0", "2017/Mar/10 11:26", "Fonderie Sime S.p.A.", "Sime", "MURELLE ONE HE 25", "", "8115010", "2017", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "20", "20", "", "", "88.5", "87.0", "", "67.1", "", "2", "", "", "104", "1", "2", "26", "4", "0", "", "", "", "0", "", "", "", "", "1", "7.851", "0.031", "0.005", "1.70563", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.9", "97.6", "", "", "", "", "95.9"]} -{"pcdb_id": 18104, "brand_name": "Baxi", "model_name": "HEAT", "model_qualifier": "212", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 13.0, "final_year_of_manufacture": null, "raw": ["018104", "000005", "0", "2018/Jun/18 14:27", "Baxi Heating", "Baxi", "HEAT", "212", "41-470-45", "2017", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "13.0", "13.0", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "17", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.3", "98.0", "", "", "", "", "96.0"]} -{"pcdb_id": 18105, "brand_name": "Baxi", "model_name": "HEAT", "model_qualifier": "215", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 16.0, "final_year_of_manufacture": null, "raw": ["018105", "000005", "0", "2018/Jun/18 14:27", "Baxi Heating", "Baxi", "HEAT", "215", "41-470-46", "2017", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "16.0", "16.0", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "20", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.3", "98.0", "", "", "", "", "96.0"]} -{"pcdb_id": 18106, "brand_name": "Baxi", "model_name": "HEAT", "model_qualifier": "218", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 19.0, "final_year_of_manufacture": null, "raw": ["018106", "000005", "0", "2018/Jun/18 14:28", "Baxi Heating", "Baxi", "HEAT", "218", "41-470-47", "2017", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "19.0", "19.0", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "23", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.3", "98.0", "", "", "", "", "96.0"]} -{"pcdb_id": 18107, "brand_name": "Baxi", "model_name": "HEAT", "model_qualifier": "224", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 25.0, "final_year_of_manufacture": null, "raw": ["018107", "000005", "0", "2018/Jun/18 14:28", "Baxi Heating", "Baxi", "HEAT", "224", "41-470-48", "2017", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "25.0", "25.0", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "33", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.3", "98.0", "", "", "", "", "96.0"]} -{"pcdb_id": 18108, "brand_name": "Baxi", "model_name": "HEAT", "model_qualifier": "230", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 30.0, "final_year_of_manufacture": null, "raw": ["018108", "000005", "0", "2018/Jun/18 14:29", "Baxi Heating", "Baxi", "HEAT", "230", "41-470-49", "2017", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "30.0", "30.0", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "44", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.3", "98.0", "", "", "", "", "96.0"]} -{"pcdb_id": 18109, "brand_name": "Baxi", "model_name": "HEAT", "model_qualifier": "412", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 13.0, "final_year_of_manufacture": null, "raw": ["018109", "000005", "0", "2018/Jun/18 14:30", "Baxi Heating", "Baxi", "HEAT", "412", "41-470-50", "2017", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "13.0", "13.0", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "17", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.3", "98.0", "", "", "", "", "96.0"]} -{"pcdb_id": 18110, "brand_name": "Baxi", "model_name": "HEAT", "model_qualifier": "415", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 16.0, "final_year_of_manufacture": null, "raw": ["018110", "000005", "0", "2018/Jun/18 14:30", "Baxi Heating", "Baxi", "HEAT", "415", "41-470-51", "2017", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "16.0", "16.0", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "20", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.3", "98.0", "", "", "", "", "96.0"]} -{"pcdb_id": 18111, "brand_name": "Baxi", "model_name": "HEAT", "model_qualifier": "418", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 19.0, "final_year_of_manufacture": null, "raw": ["018111", "000005", "0", "2018/Jun/18 14:31", "Baxi Heating", "Baxi", "HEAT", "418", "41-470-52", "2017", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "19.0", "19.0", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "23", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.3", "98.0", "", "", "", "", "96.0"]} -{"pcdb_id": 18112, "brand_name": "Baxi", "model_name": "HEAT", "model_qualifier": "424", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 25.0, "final_year_of_manufacture": null, "raw": ["018112", "000005", "0", "2018/Jun/18 14:31", "Baxi Heating", "Baxi", "HEAT", "424", "41-470-53", "2017", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "25.0", "25.0", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "33", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.3", "98.0", "", "", "", "", "96.0"]} -{"pcdb_id": 18113, "brand_name": "Baxi", "model_name": "HEAT", "model_qualifier": "430", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 30.0, "final_year_of_manufacture": null, "raw": ["018113", "000005", "0", "2018/Jun/18 14:31", "Baxi Heating", "Baxi", "HEAT", "430", "41-470-54", "2017", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "30.0", "30.0", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "44", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.3", "98.0", "", "", "", "", "96.0"]} -{"pcdb_id": 18115, "brand_name": "icon Heating", "model_name": "Base Cube", "model_qualifier": "24/35 UK", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 55.8, "output_kw_max": 24.0, "final_year_of_manufacture": null, "raw": ["018115", "000304", "0", "2017/Jun/19 09:16", "Icon Heating Solutions", "icon Heating", "Base Cube", "24/35 UK", "03-00259", "2011", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.0", "24.0", "", "", "87.9", "79.3", "", "55.8", "", "2", "", "", "104", "1", "2", "30", "4", "0", "", "", "0.02", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "86.6", "97.1", "", "", "", "", "95.1"]} -{"pcdb_id": 18116, "brand_name": "icon Heating", "model_name": "Base Cube", "model_qualifier": "30/35 UK", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 86.2, "comparative_hot_water_efficiency_pct": 82.0, "output_kw_max": 30.0, "final_year_of_manufacture": null, "raw": ["018116", "000304", "0", "2017/Oct/18 12:51", "Icon Heating Solutions", "icon Heating", "Base Cube", "30/35 UK", "03-00261", "2011", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "30.0", "30.0", "", "", "88.1", "86.2", "", "82.0", "", "2", "", "", "104", "1", "2", "30", "4", "0", "", "", "0.02", "0", "", "", "", "", "1", "6.424", "0.109", "0.0009", "0.29516", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "86.5", "97.6", "", "", "", "", "95.5"]} -{"pcdb_id": 18117, "brand_name": "icon Heating", "model_name": "Base Cube", "model_qualifier": "Duo 24/35 UK", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 86.2, "comparative_hot_water_efficiency_pct": 82.0, "output_kw_max": 24.0, "final_year_of_manufacture": null, "raw": ["018117", "000304", "0", "2017/Oct/18 12:50", "Icon Heating Solutions", "icon Heating", "Base Cube", "Duo 24/35 UK", "03-00262", "2011", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.0", "24.0", "", "", "87.9", "86.2", "", "82.0", "", "2", "", "", "104", "1", "2", "30", "4", "0", "", "", "0.02", "0", "", "", "", "", "1", "6.424", "0.109", "0.0009", "0.29726", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "86.6", "97.1", "", "", "", "", "95.1"]} -{"pcdb_id": 18118, "brand_name": "Vaillant", "model_name": "ecoTEC sustain 24", "model_qualifier": "VUW 246/7-2 (H-GB)", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 75.7, "comparative_hot_water_efficiency_pct": 76.3, "output_kw_max": 18.5, "final_year_of_manufacture": null, "raw": ["018118", "000031", "0", "2020/Nov/17 08:51", "Vaillant", "Vaillant", "ecoTEC sustain 24", "VUW 246/7-2 (H-GB)", "47-044-79", "2017", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "18.5", "18.5", "", "", "88.6", "75.7", "", "76.3", "", "2", "", "", "104", "1", "2", "19", "2", "0", "", "", "", "0", "", "", "", "", "2", "6.9", "0.0826", "0.015", "0.73143", "13.729", "0.115", "0.0015", "0.0", "0.00014", "", "", "", "0045", "", "", "", "", "", "", "", "", "89.0", "97.9", "", "", "", "", "96.2"]} -{"pcdb_id": 18119, "brand_name": "Vaillant", "model_name": "ecoTEC sustain 28", "model_qualifier": "VUW 286/7-2 (H-GB)", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 87.0, "comparative_hot_water_efficiency_pct": 78.8, "output_kw_max": 18.5, "final_year_of_manufacture": null, "raw": ["018119", "000031", "0", "2020/Nov/17 08:57", "Vaillant", "Vaillant", "ecoTEC sustain 28", "VUW 286/7-2 (H-GB)", "47-044-80", "2017", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "18.5", "18.5", "", "", "88.5", "87.0", "", "78.8", "", "2", "", "", "104", "1", "2", "23", "2", "0", "", "", "", "0", "", "", "", "", "1", "6.6848", "0.0935", "0.0101", "0.55445", "13.492", "0.111", "", "", "", "", "", "", "0045", "", "", "", "", "", "", "", "", "89.1", "97.6", "", "", "", "", "96.0"]} -{"pcdb_id": 18120, "brand_name": "Vaillant", "model_name": "ecoTEC sustain 34", "model_qualifier": "VUW 346/7-2 (H-GB)", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 76.9, "output_kw_max": 18.5, "final_year_of_manufacture": null, "raw": ["018120", "000031", "0", "2021/Feb/15 12:44", "Vaillant", "Vaillant", "ecoTEC sustain 34", "VUW 346/7-2 (H-GB)", "47-044-81", "2017", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "18.5", "18.5", "", "", "88.6", "79.6", "", "76.9", "", "2", "", "", "104", "1", "2", "13", "3", "0", "", "", "", "0", "", "", "", "", "2", "6.8447", "0.1233", "0.0196", "0.65323", "13.3017", "0.1249", "0.0007", "0.0", "0.00019", "", "", "", "0045", "", "", "", "", "", "", "", "", "89.1", "97.8", "", "", "", "", "96.1"]} -{"pcdb_id": 18121, "brand_name": "Ideal", "model_name": "LOGIC CODE COMBI ESP1", "model_qualifier": "26", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 85.7, "output_kw_max": 24.3, "final_year_of_manufacture": null, "raw": ["018121", "000008", "0", "2018/Apr/03 13:51", "Ideal Boilers", "Ideal", "LOGIC CODE COMBI ESP1", "26", "47-349-35", "2016", "current", "1", "2", "1", "2", "1", "", "", "2", "2", "2", "24.3", "24.3", "", "", "89.0", "87.3", "", "85.7", "", "2", "", "", "104", "1", "2", "34", "3", "0", "", "", "", "0", "", "", "", "", "1", "6.143", "0.074", "0.002", "0.09826", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "", "", "", "", "90.0", "98.6", "", "", "", "", "96.9"]} -{"pcdb_id": 18122, "brand_name": "Ideal", "model_name": "LOGIC CODE COMBI ESP1", "model_qualifier": "33", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 85.9, "output_kw_max": 24.3, "final_year_of_manufacture": null, "raw": ["018122", "000008", "0", "2017/May/25 12:26", "Ideal Boilers", "Ideal", "LOGIC CODE COMBI ESP1", "33", "47-349-36", "2016", "current", "1", "2", "1", "2", "1", "", "", "2", "2", "2", "24.3", "24.3", "", "", "89.0", "87.3", "", "85.9", "", "2", "", "", "104", "1", "2", "41", "3", "0", "", "", "", "0", "", "", "", "", "1", "6.129", "0.073", "0.0015", "0.08761", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "", "", "", "", "90.0", "98.6", "", "", "", "", "96.9"]} -{"pcdb_id": 18123, "brand_name": "Ideal", "model_name": "LOGIC CODE COMBI ESP1", "model_qualifier": "38", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 84.8, "output_kw_max": 24.3, "final_year_of_manufacture": null, "raw": ["018123", "000008", "0", "2017/May/25 12:19", "Ideal Boilers", "Ideal", "LOGIC CODE COMBI ESP1", "38", "47-349-37", "2016", "current", "1", "2", "1", "2", "1", "", "", "2", "2", "2", "24.3", "24.3", "", "", "89.0", "87.3", "", "84.8", "", "2", "", "", "104", "1", "2", "41", "3", "0", "", "", "", "0", "", "", "", "", "1", "6.21", "0.074", "0.002", "0.16321", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "", "", "", "", "90.0", "98.6", "", "", "", "", "96.9"]} -{"pcdb_id": 18124, "brand_name": "Ideal", "model_name": "LOGIC CODE COMBI ESP1", "model_qualifier": "33P", "winter_efficiency_pct": 90.1, "summer_efficiency_pct": 81.5, "comparative_hot_water_efficiency_pct": 57.3, "output_kw_max": 24.3, "final_year_of_manufacture": null, "raw": ["018124", "000008", "0", "2017/May/25 12:32", "Ideal Boilers", "Ideal", "LOGIC CODE COMBI ESP1", "33P", "47-349-36", "2016", "current", "2", "2", "1", "2", "1", "", "", "2", "2", "2", "24.3", "24.3", "", "", "90.1", "81.5", "", "57.3", "", "2", "1", "", "104", "1", "2", "41", "3", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "", "", "", "", "92.0", "100.8", "", "", "", "", "99.1"]} -{"pcdb_id": 18125, "brand_name": "Ideal", "model_name": "LOGIC CODE COMBI ESP1", "model_qualifier": "38P", "winter_efficiency_pct": 90.1, "summer_efficiency_pct": 81.5, "comparative_hot_water_efficiency_pct": 57.3, "output_kw_max": 24.3, "final_year_of_manufacture": null, "raw": ["018125", "000008", "0", "2017/May/25 12:31", "Ideal Boilers", "Ideal", "LOGIC CODE COMBI ESP1", "38P", "47-349-37", "2016", "current", "2", "2", "1", "2", "1", "", "", "2", "2", "2", "24.3", "24.3", "", "", "90.1", "81.5", "", "57.3", "", "2", "1", "", "104", "1", "2", "41", "3", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "", "", "", "", "92.0", "100.8", "", "", "", "", "99.1"]} -{"pcdb_id": 18127, "brand_name": "Viessmann", "model_name": "Vitodens 100-W", "model_qualifier": "B1HC-19", "winter_efficiency_pct": 89.6, "summer_efficiency_pct": 80.6, "comparative_hot_water_efficiency_pct": 58.8, "output_kw_max": 17.4, "final_year_of_manufacture": null, "raw": ["018127", "000033", "0", "2017/Apr/12 16:53", "Viessmann", "Viessmann", "Vitodens 100-W", "B1HC-19", "41-819-40", "2016", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "17.4", "17.4", "", "", "89.6", "80.6", "", "58.8", "", "2", "0", "", "102", "1", "2", "19", "60", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.8", "97.4", "", "", "", "", "96.2"]} -{"pcdb_id": 18128, "brand_name": "Viessmann", "model_name": "Vitodens 100-W", "model_qualifier": "B1HC-26", "winter_efficiency_pct": 89.8, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 59.0, "output_kw_max": 23.8, "final_year_of_manufacture": null, "raw": ["018128", "000033", "0", "2017/Apr/12 16:53", "Viessmann", "Viessmann", "Vitodens 100-W", "B1HC-26", "41-819-41", "2016", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "23.8", "23.8", "", "", "89.8", "80.8", "", "59.0", "", "2", "0", "", "102", "1", "2", "19", "60", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.8", "98.0", "", "", "", "", "96.6"]} -{"pcdb_id": 18129, "brand_name": "Viessmann", "model_name": "Vitodens 100-W", "model_qualifier": "B1HC-30", "winter_efficiency_pct": 90.0, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 59.1, "output_kw_max": 27.5, "final_year_of_manufacture": null, "raw": ["018129", "000033", "0", "2017/Apr/12 16:53", "Viessmann", "Viessmann", "Vitodens 100-W", "B1HC-30", "41-819-412", "2016", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "27.5", "27.5", "", "", "90.0", "81.0", "", "59.1", "", "2", "0", "", "102", "1", "2", "24", "58", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "91.0", "98.4", "", "", "", "", "97.0"]} -{"pcdb_id": 18130, "brand_name": "Viessmann", "model_name": "Vitodens 100-W", "model_qualifier": "B1HC-35", "winter_efficiency_pct": 90.1, "summer_efficiency_pct": 81.1, "comparative_hot_water_efficiency_pct": 59.3, "output_kw_max": 32.1, "final_year_of_manufacture": null, "raw": ["018130", "000033", "0", "2017/Apr/12 16:53", "Viessmann", "Viessmann", "Vitodens 100-W", "B1HC-35", "41-819-43", "2016", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "32.1", "32.1", "", "", "90.1", "81.1", "", "59.3", "", "2", "0", "", "102", "1", "2", "25", "58", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "91.4", "98.6", "", "", "", "", "97.3"]} -{"pcdb_id": 18131, "brand_name": "Viessmann", "model_name": "Vitodens 100-W", "model_qualifier": "B1KC-26", "winter_efficiency_pct": 89.8, "summer_efficiency_pct": 81.2, "comparative_hot_water_efficiency_pct": 57.1, "output_kw_max": 23.8, "final_year_of_manufacture": null, "raw": ["018131", "000033", "0", "2017/Apr/12 16:53", "Viessmann", "Viessmann", "Vitodens 100-W", "B1KC-26", "47-819-40", "2016", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "23.8", "23.8", "", "", "89.8", "81.2", "", "57.1", "", "2", "0", "", "104", "1", "2", "22", "59", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.8", "98.0", "", "", "", "", "96.6"]} -{"pcdb_id": 18132, "brand_name": "Viessmann", "model_name": "Vitodens 100-W", "model_qualifier": "B1KC-30", "winter_efficiency_pct": 90.0, "summer_efficiency_pct": 81.4, "comparative_hot_water_efficiency_pct": 57.2, "output_kw_max": 27.5, "final_year_of_manufacture": null, "raw": ["018132", "000033", "0", "2017/Apr/12 16:53", "Viessmann", "Viessmann", "Vitodens 100-W", "B1KC-30", "47-819-41", "2016", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "27.5", "27.5", "", "", "90.0", "81.4", "", "57.2", "", "2", "0", "", "104", "1", "2", "24", "58", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "91.0", "98.4", "", "", "", "", "97.0"]} -{"pcdb_id": 18133, "brand_name": "Viessmann", "model_name": "Vitodens 100-W", "model_qualifier": "B1KC-35", "winter_efficiency_pct": 90.1, "summer_efficiency_pct": 81.5, "comparative_hot_water_efficiency_pct": 57.3, "output_kw_max": 32.1, "final_year_of_manufacture": null, "raw": ["018133", "000033", "0", "2017/Apr/12 16:54", "Viessmann", "Viessmann", "Vitodens 100-W", "B1KC-35", "47-819-42", "2016", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "32.1", "32.1", "", "", "90.1", "81.5", "", "57.3", "", "2", "0", "", "104", "1", "2", "25", "58", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "91.4", "98.6", "", "", "", "", "97.3"]} -{"pcdb_id": 18134, "brand_name": "Viessmann", "model_name": "Vitodens 050-W BPJD", "model_qualifier": "29kW", "winter_efficiency_pct": 89.3, "summer_efficiency_pct": 90.3, "comparative_hot_water_efficiency_pct": 72.5, "output_kw_max": 21.9, "final_year_of_manufacture": null, "raw": ["018134", "000033", "0", "2020/Apr/09 16:01", "Viessmann", "Viessmann", "Vitodens 050-W BPJD", "29kW", "47-819-38", "2016", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "21.9", "21.9", "", "", "89.3", "90.3", "", "72.5", "", "2", "0", "", "104", "1", "2", "17", " 3", "0", "", "", "", "0", "", "", "", "", "2", "7.425", "0.106", "0.002", "1.30217", "13.336", "0.12", "0.001", "1.2776", "0.00001", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.5", "97.0", "", "", "", "", "95.8"]} -{"pcdb_id": 18136, "brand_name": "Sime", "model_name": "MURELLE HE 70 R ErP", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 63.4, "final_year_of_manufacture": null, "raw": ["018136", "000213", "0", "2017/May/10 17:02", "Fonderie Sime S.p.A.", "Sime", "MURELLE HE 70 R ErP", "", "8104981", "2017", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "63.4", "63.4", "", "", "88.3", "79.3", "", "57.9", "", "2", "", "", "102", "1", "2", "18", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "97.6", "", "", "", "", "95.7"]} -{"pcdb_id": 18137, "brand_name": "Trianco", "model_name": "Slimline Combi", "model_qualifier": "26", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 82.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 26.0, "final_year_of_manufacture": null, "raw": ["018137", "000047", "0", "2017/May/17 11:52", "Firebird Heating Solutions Ltd", "Trianco", "Slimline Combi", "26", "", "2009", "current", "4", "1", "1", "2", "0", "", "", "2", "2", "1", "26", "26", "", "", "89.4", "82.0", "", "57.7", "", "2", "", "", "202", "1", "1", "148", "3", "0", "", "", "11.01", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "93.0", "97.5", "", "", "", "", "96.7"]} -{"pcdb_id": 18138, "brand_name": "Trianco", "model_name": "Heatpac Condensing Boiler", "model_qualifier": "12-20kW", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 81.6, "comparative_hot_water_efficiency_pct": 59.6, "output_kw_max": 20.0, "final_year_of_manufacture": null, "raw": ["018138", "000047", "0", "2017/May/04 16:34", "Firebird Heating Solutions Ltd", "Trianco", "Heatpac Condensing Boiler", "12-20kW", "", "2009", "current", "4", "1", "2", "1", "0", "", "", "2", "1", "1", "12.0", "20.0", "", "", "89.4", "81.6", "", "59.6", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "93.1", "97.4", "", "", "", "", "96.6"]} -{"pcdb_id": 18139, "brand_name": "Trianco", "model_name": "Heatpac Condensing Boiler", "model_qualifier": "20/26kW", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 81.6, "comparative_hot_water_efficiency_pct": 59.6, "output_kw_max": 26.0, "final_year_of_manufacture": null, "raw": ["018139", "000047", "0", "2017/May/17 11:51", "Firebird Heating Solutions Ltd", "Trianco", "Heatpac Condensing Boiler", "20/26kW", "", "2009", "current", "4", "1", "2", "1", "0", "", "", "2", "1", "1", "20", "26", "", "", "89.4", "81.6", "", "59.6", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "93.0", "97.5", "", "", "", "", "96.7"]} -{"pcdb_id": 18140, "brand_name": "Trianco", "model_name": "Slimline Combi", "model_qualifier": "20", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 82.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 20.0, "final_year_of_manufacture": null, "raw": ["018140", "000047", "0", "2017/May/17 11:51", "Firebird Heating Solutions Ltd", "Trianco", "Slimline Combi", "20", "", "2009", "current", "4", "1", "1", "2", "0", "", "", "2", "2", "1", "20", "20", "", "", "89.4", "82.0", "", "57.7", "", "2", "", "", "202", "1", "1", "", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "93.1", "97.4", "", "", "", "", "96.6"]} -{"pcdb_id": 18141, "brand_name": "Saturn", "model_name": "NHC 25H", "model_qualifier": "", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 81.1, "comparative_hot_water_efficiency_pct": 59.2, "output_kw_max": 24.0, "final_year_of_manufacture": null, "raw": ["018141", "000268", "0", "2017/Jun/13 10:28", "KD Navien", "Saturn", "NHC 25H", "", "", "2006", "current", "4", "1", "1", "1", "0", "", "", "2", "1", "2", "24.0", "24.0", "", "", "88.9", "81.1", "", "59.2", "", "2", "", "", "201", "1", "1", "136", "13", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.5", "96.7", "", "", "", "", "95.7"]} -{"pcdb_id": 18142, "brand_name": "Saturn", "model_name": "NHC 25EH", "model_qualifier": "", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 81.1, "comparative_hot_water_efficiency_pct": 59.2, "output_kw_max": 24.0, "final_year_of_manufacture": null, "raw": ["018142", "000268", "0", "2017/Jun/13 10:27", "KD Navien", "Saturn", "NHC 25EH", "", "", "2006", "current", "4", "1", "2", "1", "0", "", "", "2", "1", "2", "24.0", "24.0", "", "", "88.9", "81.1", "", "59.2", "", "2", "", "", "201", "1", "1", "136", "13", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.5", "96.7", "", "", "", "", "95.7"]} -{"pcdb_id": 18143, "brand_name": "Saturn", "model_name": "NCH 30H", "model_qualifier": "", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 80.4, "comparative_hot_water_efficiency_pct": 58.7, "output_kw_max": 27.9, "final_year_of_manufacture": null, "raw": ["018143", "000268", "0", "2017/Jun/13 10:27", "KD Navien", "Saturn", "NCH 30H", "", "", "2006", "current", "4", "1", "1", "1", "0", "", "", "2", "1", "2", "27.9", "27.9", "", "", "88.2", "80.4", "", "58.7", "", "2", "", "", "201", "1", "1", "145", "14", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.7", "95.4", "", "", "", "", "94.5"]} -{"pcdb_id": 18144, "brand_name": "Saturn", "model_name": "NHC 30EH", "model_qualifier": "", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 80.4, "comparative_hot_water_efficiency_pct": 58.7, "output_kw_max": 27.9, "final_year_of_manufacture": null, "raw": ["018144", "000268", "0", "2017/Jun/13 10:26", "KD Navien", "Saturn", "NHC 30EH", "", "", "2006", "current", "4", "1", "2", "1", "0", "", "", "2", "1", "2", "27.9", "27.9", "", "", "88.2", "80.4", "", "58.7", "", "2", "", "", "201", "1", "1", "145", "14", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.7", "95.4", "", "", "", "", "94.5"]} -{"pcdb_id": 18145, "brand_name": "Saturn", "model_name": "NHC 41H", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 80.7, "comparative_hot_water_efficiency_pct": 58.9, "output_kw_max": 36.8, "final_year_of_manufacture": null, "raw": ["018145", "000268", "0", "2017/Jun/13 10:25", "KD Navien", "Saturn", "NHC 41H", "", "", "2006", "current", "4", "1", "1", "1", "0", "", "", "2", "1", "2", "36.8", "36.8", "", "", "88.5", "80.7", "", "58.9", "", "2", "", "", "201", "1", "1", "163", "12", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.1", "95.9", "", "", "", "", "95.0"]} -{"pcdb_id": 18146, "brand_name": "Saturn", "model_name": "NHC 41EH", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 80.7, "comparative_hot_water_efficiency_pct": 58.9, "output_kw_max": 36.8, "final_year_of_manufacture": null, "raw": ["018146", "000268", "0", "2017/Jun/14 09:43", "KD Navien", "Saturn", "NHC 41EH", "", "", "2006", "current", "4", "1", "2", "1", "0", "", "", "2", "1", "2", "36.8", "36.8", "", "", "88.5", "80.7", "", "58.9", "", "2", "", "", "201", "1", "1", "163", "12", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.1", "95.9", "", "", "", "", "95.0"]} -{"pcdb_id": 18147, "brand_name": "Trianco", "model_name": "Kitchen Condensing Boiler", "model_qualifier": "12-18kW", "winter_efficiency_pct": 89.3, "summer_efficiency_pct": 81.5, "comparative_hot_water_efficiency_pct": 59.5, "output_kw_max": 18.0, "final_year_of_manufacture": null, "raw": ["018147", "000047", "0", "2017/May/17 11:53", "Firebird Heating Solutions Ltd", "Trianco", "Kitchen Condensing Boiler", "12-18kW", "", "2015", "current", "4", "1", "1", "1", "0", "", "", "2", "2", "1", "12", "18", "", "", "89.3", "81.5", "", "59.5", "", "2", "", "", "201", "1", "1", "163", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "92.8", "97.3", "", "", "", "", "96.4"]} -{"pcdb_id": 18148, "brand_name": "Trianco", "model_name": "Kitchen Condensing Boiler", "model_qualifier": "12-20kW", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 81.6, "comparative_hot_water_efficiency_pct": 59.6, "output_kw_max": 20.0, "final_year_of_manufacture": null, "raw": ["018148", "000047", "0", "2017/May/17 11:53", "Firebird Heating Solutions Ltd", "Trianco", "Kitchen Condensing Boiler", "12-20kW", "", "2009", "current", "4", "1", "1", "1", "0", "", "", "2", "2", "1", "12", "20", "", "", "89.4", "81.6", "", "59.6", "", "2", "", "", "201", "1", "1", "158", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "93.1", "97.4", "", "", "", "", "96.6"]} -{"pcdb_id": 18149, "brand_name": "Trianco", "model_name": "Kitchen Condensing Boiler", "model_qualifier": "20-26kW", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 81.6, "comparative_hot_water_efficiency_pct": 59.6, "output_kw_max": 26.0, "final_year_of_manufacture": null, "raw": ["018149", "000047", "0", "2017/May/17 11:53", "Firebird Heating Solutions Ltd", "Trianco", "Kitchen Condensing Boiler", "20-26kW", "", "2009", "current", "4", "1", "1", "1", "0", "", "", "2", "2", "1", "20", "26", "", "", "89.4", "81.6", "", "59.6", "", "2", "", "", "201", "1", "1", "14.8", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "93.0", "97.5", "", "", "", "", "96.7"]} -{"pcdb_id": 18150, "brand_name": "Alpha", "model_name": "Evoke", "model_qualifier": "33 LPG", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 90.3, "comparative_hot_water_efficiency_pct": 77.1, "output_kw_max": 28.0, "final_year_of_manufacture": null, "raw": ["018150", "000001", "0", "2020/Apr/09 15:58", "Alpha Therm", "Alpha", "Evoke", "33 LPG", "3.027377GPL", "2017", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "28", "28", "", "", "89.4", "90.3", "", "77.1", "", "2", "1", "", "104", "1", "2", "12", "2", "0", "", "", "", "0", "", "", "", "", "2", "6.979", "0.096", "0.0045", "0.84841", "12.541", "0.117", "0.004", "0.83445", "0.00001", "", "", "", "1005", "", "", "", "", "", "", "", "", "90.2", "99.8", "", "", "", "", "98.0"]} -{"pcdb_id": 18151, "brand_name": "Alpha", "model_name": "Evoke", "model_qualifier": "28 LPG", "winter_efficiency_pct": 89.3, "summer_efficiency_pct": 88.9, "comparative_hot_water_efficiency_pct": 77.5, "output_kw_max": 24.0, "final_year_of_manufacture": null, "raw": ["018151", "000001", "0", "2020/Apr/09 15:57", "Alpha Therm", "Alpha", "Evoke", "28 LPG", "3.027376GPL", "2017", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "89.3", "88.9", "", "77.5", "", "2", "1", "", "104", "1", "2", "10", "2", "0", "", "", "", "0", "", "", "", "", "2", "6.945", "0.08", "0.009", "0.7871", "12.961", "0.11", "0.0045", "0.67526", "0.00005", "", "", "", "1005", "", "", "", "", "", "", "", "", "90.1", "99.7", "", "", "", "", "97.9"]} -{"pcdb_id": 18152, "brand_name": "Alpha", "model_name": "E-Tec", "model_qualifier": "33 LPG", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 90.3, "comparative_hot_water_efficiency_pct": 77.1, "output_kw_max": 28.0, "final_year_of_manufacture": null, "raw": ["018152", "000001", "0", "2020/Apr/09 15:55", "Alpha Therm", "Alpha", "E-Tec", "33 LPG", "3.027375GPL", "2017", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "28", "28", "", "", "89.4", "90.3", "", "77.1", "", "2", "1", "", "104", "1", "2", "12", "2", "0", "", "", "", "0", "", "", "", "", "2", "6.979", "0.096", "0.0045", "0.84841", "12.541", "0.117", "0.004", "0.83445", "0.00001", "", "", "", "1005", "", "", "", "", "", "", "", "", "90.2", "99.8", "", "", "", "", "98.0"]} -{"pcdb_id": 18153, "brand_name": "Alpha", "model_name": "E-Tec", "model_qualifier": "28 LPG", "winter_efficiency_pct": 89.3, "summer_efficiency_pct": 90.3, "comparative_hot_water_efficiency_pct": 77.5, "output_kw_max": 24.0, "final_year_of_manufacture": null, "raw": ["018153", "000001", "0", "2020/Apr/09 15:54", "Alpha Therm", "Alpha", "E-Tec", "28 LPG", "3.027374GPL", "2017", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "89.3", "90.3", "", "77.5", "", "2", "1", "", "104", "1", "2", "10", "2", "0", "", "", "", "0", "", "", "", "", "2", "6.945", "0.119", "0.009", "0.7871", "12.691", "0.11", "0.0045", "0.77548", "0.00005", "", "", "", "1005", "", "", "", "", "", "", "", "", "90.1", "99.7", "", "", "", "", "97.9"]} -{"pcdb_id": 18154, "brand_name": "Alpha", "model_name": "E-Tec", "model_qualifier": "33", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 88.2, "comparative_hot_water_efficiency_pct": 74.7, "output_kw_max": 28.0, "final_year_of_manufacture": null, "raw": ["018154", "000001", "0", "2020/Apr/09 15:52", "Alpha Therm", "Alpha", "E-Tec", "33", "3.027375", "2017", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28", "28", "", "", "88.4", "88.2", "", "74.7", "", "2", "", "", "104", "1", "2", "12", "2", "0", "", "", "", "0", "", "", "", "", "2", "7.051", "0.095", "0.0085", "0.89436", "12.849", "0.125", "0.004", "0.86958", "0.00005", "", "", "", "1005", "", "", "", "", "", "", "", "", "88.2", "97.7", "", "", "", "", "95.9"]} -{"pcdb_id": 18155, "brand_name": "Alpha", "model_name": "E-Tec", "model_qualifier": "28", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 88.2, "comparative_hot_water_efficiency_pct": 75.2, "output_kw_max": 24.0, "final_year_of_manufacture": null, "raw": ["018155", "000001", "0", "2020/Apr/09 15:51", "Alpha Therm", "Alpha", "E-Tec", "28", "3.027374", "2017", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "88.3", "88.2", "", "75.2", "", "2", "", "", "104", "1", "2", "10", "2", "0", "", "", "", "0", "", "", "", "", "2", "7.002", "0.082", "0.0055", "0.86242", "12.57", "0.112", "0.0045", "0.84011", "0.00001", "", "", "", "1005", "", "", "", "", "", "", "", "", "88.1", "97.6", "", "", "", "", "95.8"]} -{"pcdb_id": 18156, "brand_name": "Alpha", "model_name": "Evoke", "model_qualifier": "33", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 88.2, "comparative_hot_water_efficiency_pct": 74.7, "output_kw_max": 28.0, "final_year_of_manufacture": null, "raw": ["018156", "000001", "0", "2020/Apr/09 15:49", "Alpha Therm", "Alpha", "Evoke", "33", "3.027377", "2017", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28", "28", "", "", "88.4", "88.2", "", "74.7", "", "2", "", "", "104", "1", "2", "12", "2", "0", "", "", "", "0", "", "", "", "", "2", "7.051", "0.095", "0.0085", "0.89436", "12.849", "0.125", "0.004", "0.86958", "0.00005", "", "", "", "1005", "", "", "", "", "", "", "", "", "88.2", "97.7", "", "", "", "", "95.9"]} -{"pcdb_id": 18157, "brand_name": "Alpha", "model_name": "Evoke", "model_qualifier": "28", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 88.2, "comparative_hot_water_efficiency_pct": 75.2, "output_kw_max": 24.0, "final_year_of_manufacture": null, "raw": ["018157", "000001", "0", "2020/Apr/09 15:45", "Alpha Therm", "Alpha", "Evoke", "28", "3.027376", "2017", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "88.3", "88.2", "", "75.2", "", "2", "", "", "104", "1", "2", "10", "2", "0", "", "", "", "0", "", "", "", "", "2", "7.002", "0.082", "0.0055", "0.86242", "12.57", "0.112", "0.0045", "0.84011", "0.00001", "", "", "", "1005", "", "", "", "", "", "", "", "", "88.1", "97.6", "", "", "", "", "95.8"]} -{"pcdb_id": 18158, "brand_name": "Firebird Enviromax", "model_name": "Combipac HE", "model_qualifier": "26kW", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 81.7, "comparative_hot_water_efficiency_pct": 57.5, "output_kw_max": 26.0, "final_year_of_manufacture": null, "raw": ["018158", "000047", "0", "2017/May/17 11:56", "Firebird Heating Solutions Ltd", "Firebird Enviromax", "Combipac HE", "26kW", "", "2017", "current", "4", "1", "2", "2", "0", "", "", "2", "3", "1", "26", "26", "", "", "89.1", "81.7", "", "57.5", "", "2", "", "", "202", "1", "1", "143", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "92.7", "96.9", "", "", "", "", "96.1"]} -{"pcdb_id": 18159, "brand_name": "Trianco", "model_name": "Combipac HE", "model_qualifier": "26", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 81.7, "comparative_hot_water_efficiency_pct": 57.5, "output_kw_max": 26.0, "final_year_of_manufacture": null, "raw": ["018159", "000047", "0", "2017/May/17 11:56", "Firebird Heating Solutions Ltd", "Trianco", "Combipac HE", "26", "", "2017", "current", "4", "1", "2", "2", "0", "", "", "2", "3", "1", "26", "26", "", "", "89.1", "81.7", "", "57.5", "", "2", "", "", "202", "1", "1", "143", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "92.7", "96.9", "", "", "", "", "96.1"]} -{"pcdb_id": 18160, "brand_name": "Ravenheat", "model_name": "HE 98 (T)", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 55.9, "output_kw_max": 23.8, "final_year_of_manufacture": null, "raw": ["018160", "000026", "0", "2017/Aug/09 16:15", "Ravenheat Manufacturing", "Ravenheat", "HE 98 (T)", "", "", "2016", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "23.8", "23.8", "", "", "88.1", "79.5", "", "55.9", "", "2", "", "", "104", "1", "2", "810", "5.2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "96.9", "", "", "", "", "95.2"]} -{"pcdb_id": 18161, "brand_name": "Firebird", "model_name": "Enviromax Heatpac", "model_qualifier": "C12/20kW", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 81.6, "comparative_hot_water_efficiency_pct": 59.6, "output_kw_max": 20.0, "final_year_of_manufacture": null, "raw": ["018161", "000047", "0", "2017/Aug/14 15:49", "Firebird Heating Solutions Ltd", "Firebird", "Enviromax Heatpac", "C12/20kW", "", "2009", "current", "4", "1", "2", "1", "0", "", "", "2", "1", "1", "12", "20", "", "", "89.4", "81.6", "", "59.6", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "93.1", "97.4", "", "", "", "", "96.6"]} -{"pcdb_id": 18162, "brand_name": "Firebird", "model_name": "Enviromax Kitchen System", "model_qualifier": "C12/20kW", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 81.6, "comparative_hot_water_efficiency_pct": 59.6, "output_kw_max": 20.0, "final_year_of_manufacture": null, "raw": ["018162", "000047", "0", "2017/Aug/14 15:49", "Firebird Heating Solutions Ltd", "Firebird", "Enviromax Kitchen System", "C12/20kW", "", "2009", "current", "4", "1", "1", "1", "0", "", "", "2", "2", "1", "12", "20", "", "", "89.4", "81.6", "", "59.6", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "93.1", "97.4", "", "", "", "", "96.6"]} -{"pcdb_id": 18163, "brand_name": "Firebird", "model_name": "Enviromax Popular", "model_qualifier": "C12/20kW", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 81.6, "comparative_hot_water_efficiency_pct": 59.6, "output_kw_max": 20.0, "final_year_of_manufacture": null, "raw": ["018163", "000047", "0", "2017/Aug/14 15:50", "Firebird Heating Solutions Ltd", "Firebird", "Enviromax Popular", "C12/20kW", "", "2009", "current", "4", "1", "1", "1", "0", "", "", "2", "2", "1", "12", "20", "", "", "89.4", "81.6", "", "59.6", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "93.1", "97.4", "", "", "", "", "96.6"]} -{"pcdb_id": 18164, "brand_name": "Potterton", "model_name": "Ultra 12 System", "model_qualifier": "12", "winter_efficiency_pct": 89.6, "summer_efficiency_pct": 80.6, "comparative_hot_water_efficiency_pct": 58.8, "output_kw_max": 12.0, "final_year_of_manufacture": null, "raw": ["018164", "000005", "0", "2017/Aug/07 13:34", "Baxi Heating", "Potterton", "Ultra 12 System", "12", "41-592-71", "2017", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "12", "12", "", "", "89.6", "80.6", "", "58.8", "", "2", "1", "", "102", "1", "2", "30", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.1", "100.3", "", "", "", "", "98.4"]} -{"pcdb_id": 18165, "brand_name": "Potterton", "model_name": "Ultra 12 System", "model_qualifier": "12", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 12.0, "final_year_of_manufacture": null, "raw": ["018165", "000005", "0", "2017/Aug/07 13:34", "Baxi Heating", "Potterton", "Ultra 12 System", "12", "41-592-71", "2017", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "12", "12", "", "", "88.5", "79.5", "", "58.1", "", "2", "", "", "102", "1", "2", "30", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.1", "98.1", "", "", "", "", "96.2"]} -{"pcdb_id": 18166, "brand_name": "Potterton", "model_name": "Ultra 15 System", "model_qualifier": "15", "winter_efficiency_pct": 89.5, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 58.8, "output_kw_max": 15.0, "final_year_of_manufacture": null, "raw": ["018166", "000005", "0", "2017/Aug/07 13:35", "Baxi Heating", "Potterton", "Ultra 15 System", "15", "41-592-72", "2017", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "15", "15", "", "", "89.5", "80.5", "", "58.8", "", "2", "1", "", "102", "1", "2", "30", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.0", "100.3", "", "", "", "", "98.3"]} -{"pcdb_id": 18167, "brand_name": "Potterton", "model_name": "Ultra 15 System", "model_qualifier": "15", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 15.0, "final_year_of_manufacture": null, "raw": ["018167", "000005", "0", "2017/Aug/07 13:35", "Baxi Heating", "Potterton", "Ultra 15 System", "15", "41-592-72", "2017", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "15", "15", "", "", "88.5", "79.5", "", "58.1", "", "2", "", "", "102", "1", "2", "30", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "98.1", "", "", "", "", "96.2"]} -{"pcdb_id": 18168, "brand_name": "Potterton", "model_name": "Ultra 18 System", "model_qualifier": "18", "winter_efficiency_pct": 89.5, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 58.8, "output_kw_max": 18.0, "final_year_of_manufacture": null, "raw": ["018168", "000005", "0", "2017/Aug/07 13:36", "Baxi Heating", "Potterton", "Ultra 18 System", "18", "41-592-73", "2017", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "18", "18", "", "", "89.5", "80.5", "", "58.8", "", "2", "1", "", "102", "1", "2", "30", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.0", "100.3", "", "", "", "", "98.3"]} -{"pcdb_id": 18169, "brand_name": "Potterton", "model_name": "Ultra 18 System", "model_qualifier": "18", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 18.0, "final_year_of_manufacture": null, "raw": ["018169", "000005", "0", "2017/Aug/07 13:36", "Baxi Heating", "Potterton", "Ultra 18 System", "18", "41-592-73", "2017", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18", "18", "", "", "88.5", "79.5", "", "58.1", "", "2", "", "", "102", "1", "2", "30", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "98.1", "", "", "", "", "96.2"]} -{"pcdb_id": 18170, "brand_name": "Potterton", "model_name": "Ultra 24 System", "model_qualifier": "24", "winter_efficiency_pct": 89.5, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 58.8, "output_kw_max": 24.0, "final_year_of_manufacture": null, "raw": ["018170", "000005", "0", "2017/Aug/07 13:37", "Baxi Heating", "Potterton", "Ultra 24 System", "24", "41-592-74", "2017", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "24", "24", "", "", "89.5", "80.5", "", "58.8", "", "2", "1", "", "102", "1", "2", "42", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.9", "100.2", "", "", "", "", "98.2"]} -{"pcdb_id": 18171, "brand_name": "Potterton", "model_name": "Ultra 24 System", "model_qualifier": "24", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 24.0, "final_year_of_manufacture": null, "raw": ["018171", "000005", "0", "2017/Aug/07 13:37", "Baxi Heating", "Potterton", "Ultra 24 System", "24", "41-592-74", "2017", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24", "24", "", "", "88.5", "79.5", "", "58.1", "", "2", "", "", "102", "1", "2", "42", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "98.0", "", "", "", "", "96.1"]} -{"pcdb_id": 18172, "brand_name": "Potterton", "model_name": "Ultra 28 System", "model_qualifier": "28", "winter_efficiency_pct": 89.5, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 58.8, "output_kw_max": 28.0, "final_year_of_manufacture": null, "raw": ["018172", "000005", "0", "2017/Aug/07 14:30", "Baxi Heating", "Potterton", "Ultra 28 System", "28", "41-592-75", "2017", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "28", "28", "", "", "89.5", "80.5", "", "58.8", "", "2", "1", "", "102", "1", "2", "47", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.9", "100.2", "", "", "", "", "98.2"]} -{"pcdb_id": 18173, "brand_name": "Potterton", "model_name": "Ultra 28 System", "model_qualifier": "28", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 28.0, "final_year_of_manufacture": null, "raw": ["018173", "000005", "0", "2017/Aug/07 13:39", "Baxi Heating", "Potterton", "Ultra 28 System", "28", "41-592-75", "2017", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "28", "28", "", "", "88.5", "79.5", "", "58.1", "", "2", "", "", "102", "1", "2", "47", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "98.0", "", "", "", "", "96.1"]} -{"pcdb_id": 18174, "brand_name": "Firebird", "model_name": "Envirormax Kitchen", "model_qualifier": "C12/20kW", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 81.6, "comparative_hot_water_efficiency_pct": 59.6, "output_kw_max": 20.0, "final_year_of_manufacture": null, "raw": ["018174", "000047", "0", "2017/Aug/14 15:50", "Firebird Heating Solutions Ltd", "Firebird", "Envirormax Kitchen", "C12/20kW", "", "2009", "current", "4", "1", "1", "1", "0", "", "", "2", "2", "1", "12", "20", "", "", "89.4", "81.6", "", "59.6", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "93.1", "97.4", "", "", "", "", "96.6"]} -{"pcdb_id": 18175, "brand_name": "Firebird", "model_name": "Enviromax Systempac", "model_qualifier": "C12/20kW", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 81.6, "comparative_hot_water_efficiency_pct": 59.6, "output_kw_max": 20.0, "final_year_of_manufacture": null, "raw": ["018175", "000047", "0", "2017/Aug/14 15:50", "Firebird Heating Solutions Ltd", "Firebird", "Enviromax Systempac", "C12/20kW", "", "2009", "current", "4", "1", "2", "1", "0", "", "", "2", "1", "1", "12", "20", "", "", "89.4", "81.6", "", "59.6", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "93.1", "97.4", "", "", "", "", "96.6"]} -{"pcdb_id": 18176, "brand_name": "Potterton", "model_name": "Ultra 12 Heat", "model_qualifier": "12", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 13.0, "final_year_of_manufacture": null, "raw": ["018176", "000005", "0", "2017/Aug/07 13:39", "Baxi Heating", "Potterton", "Ultra 12 Heat", "12", "41-592-56", "2017", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "13", "13", "", "", "88.5", "79.5", "", "58.1", "", "2", "", "", "102", "1", "2", "17", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "98.0", "", "", "", "", "96.1"]} -{"pcdb_id": 18177, "brand_name": "Potterton", "model_name": "Ultra 15 Heat", "model_qualifier": "15", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 16.0, "final_year_of_manufacture": null, "raw": ["018177", "000005", "0", "2017/Aug/07 13:40", "Baxi Heating", "Potterton", "Ultra 15 Heat", "15", "41-592-57", "2017", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "16", "16", "", "", "88.5", "79.5", "", "58.1", "", "2", "", "", "102", "1", "2", "20", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.1", "98.0", "", "", "", "", "96.1"]} -{"pcdb_id": 18178, "brand_name": "Potterton", "model_name": "Ultra 18 Heat", "model_qualifier": "18", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 19.0, "final_year_of_manufacture": null, "raw": ["018178", "000005", "0", "2017/Aug/07 13:40", "Baxi Heating", "Potterton", "Ultra 18 Heat", "18", "41-592-58", "2017", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "19", "19", "", "", "88.5", "79.5", "", "58.0", "", "2", "", "", "102", "1", "2", "23", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "98.0", "", "", "", "", "96.1"]} -{"pcdb_id": 18179, "brand_name": "Potterton", "model_name": "Ultra 21 Heat", "model_qualifier": "21", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 21.0, "final_year_of_manufacture": null, "raw": ["018179", "000005", "0", "2017/Aug/07 13:40", "Baxi Heating", "Potterton", "Ultra 21 Heat", "21", "41-592-59", "2017", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "21", "21", "", "", "88.5", "79.5", "", "58.0", "", "2", "", "", "102", "1", "2", "25", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "98.0", "", "", "", "", "96.1"]} -{"pcdb_id": 18180, "brand_name": "Potterton", "model_name": "Ultra 24 Heat", "model_qualifier": "24", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 25.0, "final_year_of_manufacture": null, "raw": ["018180", "000005", "0", "2017/Aug/07 13:41", "Baxi Heating", "Potterton", "Ultra 24 Heat", "24", "41-592-60", "2017", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "25", "25", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "33", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.7", "98.0", "", "", "", "", "96.1"]} -{"pcdb_id": 18181, "brand_name": "Grant", "model_name": "VORTEX", "model_qualifier": "BOILERHOUSE 15-21", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 20.7, "final_year_of_manufacture": null, "raw": ["018181", "000048", "0", "2017/Dec/04 09:59", "Grant Engineering", "Grant", "VORTEX", "BOILERHOUSE 15-21", "", "2017", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "15", "20.7", "", "", "88.0", "80.2", "", "58.6", "", "2", "", "", "201", "1", "1", "113", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.5", "94.4", "", "", "", "", "93.9"]} -{"pcdb_id": 18182, "brand_name": "Grant", "model_name": "VORTEX", "model_qualifier": "BOILERHOUSE 21-26", "winter_efficiency_pct": 87.8, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 25.6, "final_year_of_manufacture": null, "raw": ["018182", "000048", "0", "2017/Dec/04 10:00", "Grant Engineering", "Grant", "VORTEX", "BOILERHOUSE 21-26", "", "2017", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "21", "25.6", "", "", "87.8", "80.0", "", "58.4", "", "2", "", "", "201", "1", "1", "154", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.4", "94.4", "", "", "", "", "93.6"]} -{"pcdb_id": 18183, "brand_name": "Grant", "model_name": "VORTEX", "model_qualifier": "BOILERHOUSE 26-35", "winter_efficiency_pct": 87.5, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 34.7, "final_year_of_manufacture": null, "raw": ["018183", "000048", "0", "2017/Dec/04 10:01", "Grant Engineering", "Grant", "VORTEX", "BOILERHOUSE 26-35", "", "2017", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "26", "34.7", "", "", "87.5", "79.7", "", "58.2", "", "2", "", "", "201", "1", "1", "146", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.3", "93.8", "", "", "", "", "93.1"]} -{"pcdb_id": 18184, "brand_name": "Trianco", "model_name": "TRO EVOLUTION 20 BH", "model_qualifier": "", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 81.4, "comparative_hot_water_efficiency_pct": 59.4, "output_kw_max": 19.0, "final_year_of_manufacture": null, "raw": ["018184", "000062", "0", "2017/Nov/15 16:40", "TR Engineering Ltd", "Trianco", "TRO EVOLUTION 20 BH", "", "", "2017", "current", "4", "1", "1", "1", "0", "", "", "2", "2", "2", "19.0", "19.0", "", "", "89.2", "81.4", "", "59.4", "", "2", "", "", "201", "1", "1", "226", "1", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.1", "97.6", "", "", "", "", "96.4"]} -{"pcdb_id": 18185, "brand_name": "Trianco", "model_name": "TRO EVOLUTION 20 HEAT ONLY OUTDOOR", "model_qualifier": "", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 81.4, "comparative_hot_water_efficiency_pct": 59.4, "output_kw_max": 19.0, "final_year_of_manufacture": null, "raw": ["018185", "000062", "0", "2017/Nov/15 16:45", "TR Engineering Ltd", "Trianco", "TRO EVOLUTION 20 HEAT ONLY OUTDOOR", "", "", "2017", "current", "4", "1", "2", "1", "0", "", "", "2", "1", "2", "19.0", "19.0", "", "", "89.2", "81.4", "", "59.4", "", "2", "", "", "201", "1", "1", "226", "1", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.1", "97.6", "", "", "", "", "96.4"]} -{"pcdb_id": 18186, "brand_name": "Trianco", "model_name": "EVOLUTION 20 INC DHW ACCU", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 82.7, "comparative_hot_water_efficiency_pct": 50.0, "output_kw_max": 19.0, "final_year_of_manufacture": null, "raw": ["018186", "000062", "0", "2024/Jan/31 10:17", "TR Engineering Ltd", "Trianco", "EVOLUTION 20 INC DHW ACCU", "", "", "2017", "current", "4", "1", "1", "2", "0", "", "", "2", "2", "2", "19", "19", "", "", "88.8", "82.7", "", "50.0", "", "2", "", "", "203", "1", "1", "226", "1", "2", "1", "", "144", "0", "50", "2", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.5", "97.1", "", "", "", "", "95.8"]} -{"pcdb_id": 18187, "brand_name": "Trianco", "model_name": "TRO EVOLUTION 20 SYSTEM", "model_qualifier": "", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 81.4, "comparative_hot_water_efficiency_pct": 59.4, "output_kw_max": 19.0, "final_year_of_manufacture": null, "raw": ["018187", "000062", "0", "2017/Nov/15 16:41", "TR Engineering Ltd", "Trianco", "TRO EVOLUTION 20 SYSTEM", "", "", "2017", "current", "4", "1", "1", "1", "0", "", "", "2", "2", "2", "19", "19", "", "", "89.2", "81.4", "", "59.4", "", "2", "", "", "201", "1", "1", "226", "1", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.1", "97.6", "", "", "", "", "96.4"]} -{"pcdb_id": 18188, "brand_name": "Trianco", "model_name": "TRO EVOLUTION 30 BH", "model_qualifier": "", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 81.4, "comparative_hot_water_efficiency_pct": 59.5, "output_kw_max": 30.0, "final_year_of_manufacture": null, "raw": ["018188", "000062", "0", "2017/Nov/15 16:41", "TR Engineering Ltd", "Trianco", "TRO EVOLUTION 30 BH", "", "", "2017", "current", "4", "1", "1", "1", "0", "", "", "2", "2", "2", "30", "30", "", "", "89.2", "81.4", "", "59.5", "", "2", "", "", "201", "1", "1", "226", "1", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.4", "97.7", "", "", "", "", "96.5"]} -{"pcdb_id": 18189, "brand_name": "Trianco", "model_name": "TRO EVOLUTION 30 COMBI", "model_qualifier": "", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 81.8, "comparative_hot_water_efficiency_pct": 57.6, "output_kw_max": 30.0, "final_year_of_manufacture": null, "raw": ["018189", "000062", "0", "2017/Nov/15 16:42", "TR Engineering Ltd", "Trianco", "TRO EVOLUTION 30 COMBI", "", "", "2017", "current", "4", "1", "1", "2", "0", "", "", "2", "2", "2", "30", "30", "", "", "89.2", "81.8", "", "57.6", "", "2", "", "", "202", "1", "1", "226", "1", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.4", "97.7", "", "", "", "", "96.5"]} -{"pcdb_id": 18190, "brand_name": "Trianco", "model_name": "TRO EVOLUTION 30 COMBI OUTDOOR", "model_qualifier": "", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 81.8, "comparative_hot_water_efficiency_pct": 57.6, "output_kw_max": 30.0, "final_year_of_manufacture": null, "raw": ["018190", "000062", "0", "2017/Nov/15 16:42", "TR Engineering Ltd", "Trianco", "TRO EVOLUTION 30 COMBI OUTDOOR", "", "", "2017", "current", "4", "1", "2", "2", "0", "", "", "2", "1", "2", "30", "30", "", "", "89.2", "81.8", "", "57.6", "", "2", "", "", "202", "1", "1", "226", "1", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.4", "97.7", "", "", "", "", "96.5"]} -{"pcdb_id": 18191, "brand_name": "Trianco", "model_name": "TRO EVOLUTION 30 HEAT ONLY OUTDOOR", "model_qualifier": "", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 81.4, "comparative_hot_water_efficiency_pct": 59.5, "output_kw_max": 30.0, "final_year_of_manufacture": null, "raw": ["018191", "000062", "0", "2017/Nov/15 16:43", "TR Engineering Ltd", "Trianco", "TRO EVOLUTION 30 HEAT ONLY OUTDOOR", "", "", "2017", "current", "4", "1", "2", "1", "0", "", "", "2", "1", "2", "30", "30", "", "", "89.2", "81.4", "", "59.5", "", "2", "", "", "201", "1", "1", "226", "1", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.4", "97.7", "", "", "", "", "96.5"]} -{"pcdb_id": 18192, "brand_name": "Trianco", "model_name": "TRO EVOLUTION 30 INC DHW ACCU", "model_qualifier": "", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 82.8, "comparative_hot_water_efficiency_pct": 49.6, "output_kw_max": 30.0, "final_year_of_manufacture": null, "raw": ["018192", "000062", "0", "2024/Jan/31 10:17", "TR Engineering Ltd", "Trianco", "TRO EVOLUTION 30 INC DHW ACCU", "", "", "2017", "current", "4", "1", "1", "2", "0", "", "", "2", "2", "2", "30", "30", "", "", "88.9", "82.8", "", "49.6", "", "2", "", "", "203", "1", "1", "226", "1", "2", "1", "0", "149.2", "0", "50", "2", "65", "135", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.8", "97.1", "", "", "", "", "95.9"]} -{"pcdb_id": 18193, "brand_name": "Trianco", "model_name": "TRO EVOLUTION 30 SYSTEM", "model_qualifier": "", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 81.4, "comparative_hot_water_efficiency_pct": 59.5, "output_kw_max": 30.0, "final_year_of_manufacture": null, "raw": ["018193", "000062", "0", "2017/Nov/15 16:43", "TR Engineering Ltd", "Trianco", "TRO EVOLUTION 30 SYSTEM", "", "", "2017", "current", "4", "1", "1", "1", "0", "", "", "2", "2", "2", "30", "30", "", "", "89.2", "81.4", "", "59.5", "", "2", "", "", "201", "1", "1", "226", "1", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.4", "97.7", "", "", "", "", "96.5"]} -{"pcdb_id": 18194, "brand_name": "Trianco", "model_name": "TRO EVOLUTION 40 COMBI", "model_qualifier": "", "winter_efficiency_pct": 89.3, "summer_efficiency_pct": 81.9, "comparative_hot_water_efficiency_pct": 57.6, "output_kw_max": 40.0, "final_year_of_manufacture": null, "raw": ["018194", "000062", "0", "2017/Nov/15 16:43", "TR Engineering Ltd", "Trianco", "TRO EVOLUTION 40 COMBI", "", "", "2017", "current", "4", "1", "1", "2", "0", "", "", "2", "2", "2", "40", "40", "", "", "89.3", "81.9", "", "57.6", "", "2", "", "", "202", "1", "1", "226", "1", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.7", "97.8", "", "", "", "", "96.7"]} -{"pcdb_id": 18195, "brand_name": "Trianco", "model_name": "TRO EVOLUTION 40 COMBI OUTDOOR", "model_qualifier": "", "winter_efficiency_pct": 89.3, "summer_efficiency_pct": 81.9, "comparative_hot_water_efficiency_pct": 57.6, "output_kw_max": 40.0, "final_year_of_manufacture": null, "raw": ["018195", "000062", "0", "2017/Nov/15 16:43", "TR Engineering Ltd", "Trianco", "TRO EVOLUTION 40 COMBI OUTDOOR", "", "", "2017", "current", "4", "1", "2", "2", "0", "", "", "2", "1", "2", "40", "40", "", "", "89.3", "81.9", "", "57.6", "", "2", "", "", "202", "1", "1", "226", "1", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.7", "97.8", "", "", "", "", "96.7"]} -{"pcdb_id": 18196, "brand_name": "Trianco", "model_name": "TRO EVOLUTION 40 HEAT ONLY OUTDOOR", "model_qualifier": "", "winter_efficiency_pct": 89.3, "summer_efficiency_pct": 81.5, "comparative_hot_water_efficiency_pct": 59.6, "output_kw_max": 40.0, "final_year_of_manufacture": null, "raw": ["018196", "000062", "0", "2017/Nov/15 16:43", "TR Engineering Ltd", "Trianco", "TRO EVOLUTION 40 HEAT ONLY OUTDOOR", "", "", "2017", "current", "4", "1", "2", "1", "0", "", "", "2", "1", "2", "40", "40", "", "", "89.3", "81.5", "", "59.6", "", "2", "", "", "201", "1", "1", "226", "1", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.7", "97.8", "", "", "", "", "96.7"]} -{"pcdb_id": 18197, "brand_name": "Trianco", "model_name": "TRO EVOLUTION 40 INC DHW ACCU", "model_qualifier": "", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 82.9, "comparative_hot_water_efficiency_pct": 49.3, "output_kw_max": 40.0, "final_year_of_manufacture": null, "raw": ["018197", "000062", "0", "2024/Jan/31 10:17", "TR Engineering Ltd", "Trianco", "TRO EVOLUTION 40 INC DHW ACCU", "", "", "2017", "current", "4", "1", "1", "2", "0", "", "", "2", "2", "2", "40", "40", "", "", "89.0", "82.9", "", "49.3", "", "2", "", "", "203", "1", "1", "226", "1", "2", "1", "0", "153.2", "0", "50", "2", "65", "170", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.2", "97.2", "", "", "", "", "96.0"]} -{"pcdb_id": 18198, "brand_name": "Trianco", "model_name": "TRO EVOLUTION 40 SYSTEM", "model_qualifier": "", "winter_efficiency_pct": 89.3, "summer_efficiency_pct": 81.5, "comparative_hot_water_efficiency_pct": 59.6, "output_kw_max": 40.0, "final_year_of_manufacture": null, "raw": ["018198", "000062", "0", "2017/Nov/15 16:44", "TR Engineering Ltd", "Trianco", "TRO EVOLUTION 40 SYSTEM", "", "", "2017", "current", "4", "1", "1", "1", "0", "", "", "2", "2", "2", "40", "40", "", "", "89.3", "81.5", "", "59.6", "", "2", "", "", "201", "1", "1", "226", "1", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.7", "97.8", "", "", "", "", "96.7"]} -{"pcdb_id": 18199, "brand_name": "EUROTERM", "model_name": "E27 PLUS", "model_qualifier": "", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 86.7, "comparative_hot_water_efficiency_pct": 73.8, "output_kw_max": 24.5, "final_year_of_manufacture": null, "raw": ["018199", "000097", "0", "2017/Nov/08 09:59", "Ferroli", "EUROTERM", "E27 PLUS", "", "47-267-66", "2017", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.5", "24.5", "", "", "88.9", "86.7", "", "73.8", "", "2", "", "", "104", "1", "2", "39", "3", "0", "", "", "", "0", "", "", "", "", "1", "7.133", "0.084", "0.016", "0.92714", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.1", "98.9", "", "", "", "", "96.9"]} -{"pcdb_id": 18200, "brand_name": "EUROTERM", "model_name": "E32 PLUS", "model_qualifier": "", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 86.7, "comparative_hot_water_efficiency_pct": 72.4, "output_kw_max": 28.9, "final_year_of_manufacture": null, "raw": ["018200", "000097", "0", "2017/Nov/08 09:59", "Ferroli", "EUROTERM", "E32 PLUS", "", "47-267-67", "2017", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28.9", "28.9", "", "", "88.9", "86.7", "", "72.4", "", "2", "", "", "104", "1", "2", "54", "3", "0", "", "", "", "0", "", "", "", "", "1", "7.276", "0.087", "0.0085", "1.10862", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.1", "98.9", "", "", "", "", "96.9"]} -{"pcdb_id": 18201, "brand_name": "Potterton", "model_name": "Assure", "model_qualifier": "15 System", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 15.0, "final_year_of_manufacture": null, "raw": ["018201", "000005", "0", "2019/Jan/10 14:17", "Baxi Heating", "Potterton", "Assure", "15 System", "41-592-54", "2017", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "15", "15", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "57", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "88.2", "97.8", "", "", "", "", "95.9"]} -{"pcdb_id": 18202, "brand_name": "Potterton", "model_name": "Assure", "model_qualifier": "18 System", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 18.0, "final_year_of_manufacture": null, "raw": ["018202", "000005", "0", "2019/Jan/10 14:18", "Baxi Heating", "Potterton", "Assure", "18 System", "41-592-55", "2017", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18", "18", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "65", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "88.2", "97.8", "", "", "", "", "96.0"]} -{"pcdb_id": 18203, "brand_name": "Potterton", "model_name": "Assure", "model_qualifier": "25 Combi", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 86.7, "comparative_hot_water_efficiency_pct": 80.2, "output_kw_max": 20.0, "final_year_of_manufacture": null, "raw": ["018203", "000005", "0", "2020/Jan/22 13:16", "Baxi Heating", "Potterton", "Assure", "25 Combi", "47-393-58", "2017", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "20", "20", "", "", "88.4", "86.7", "", "80.2", "", "2", "", "", "104", "1", "2", "68", "3", "0", "", "", "", "0", "", "", "", "", "1", "6.563", "0.102", "0.0004", "0.46731", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "88.0", "97.8", "", "", "", "", "95.9"]} -{"pcdb_id": 18204, "brand_name": "Potterton", "model_name": "Assure", "model_qualifier": "30 Combi", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 86.7, "comparative_hot_water_efficiency_pct": 79.3, "output_kw_max": 25.0, "final_year_of_manufacture": null, "raw": ["018204", "000005", "0", "2020/Jan/22 13:16", "Baxi Heating", "Potterton", "Assure", "30 Combi", "47-393-59", "2017", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "25", "25", "", "", "88.4", "86.7", "", "79.3", "", "2", "", "", "104", "1", "2", "78", "3", "0", "", "", "", "0", "", "", "", "", "1", "6.641", "0.105", "0.0009", "0.54193", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "88.1", "97.8", "", "", "", "", "96.0"]} -{"pcdb_id": 18205, "brand_name": "Potterton", "model_name": "Assure", "model_qualifier": "13 Heat", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 13.0, "final_year_of_manufacture": null, "raw": ["018205", "000005", "0", "2017/Aug/16 11:02", "Baxi Heating", "Potterton", "Assure", "13 Heat", "41-592-66", "2017", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "13", "13", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "17", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.3", "98.0", "", "", "", "", "96.0"]} -{"pcdb_id": 18206, "brand_name": "Potterton", "model_name": "Assure", "model_qualifier": "16 Heat", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 16.0, "final_year_of_manufacture": null, "raw": ["018206", "000005", "0", "2017/Aug/16 11:03", "Baxi Heating", "Potterton", "Assure", "16 Heat", "41-592-67", "2017", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "16", "16", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "17", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.3", "98.0", "", "", "", "", "96.0"]} -{"pcdb_id": 18207, "brand_name": "Potterton", "model_name": "Assure", "model_qualifier": "19 Heat", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 19.0, "final_year_of_manufacture": null, "raw": ["018207", "000005", "0", "2017/Aug/16 11:03", "Baxi Heating", "Potterton", "Assure", "19 Heat", "41-592-68", "2017", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "19", "19", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "23", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.3", "98.0", "", "", "", "", "96.0"]} -{"pcdb_id": 18208, "brand_name": "Potterton", "model_name": "Assure", "model_qualifier": "25 Heat", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 25.0, "final_year_of_manufacture": null, "raw": ["018208", "000005", "0", "2017/Aug/16 11:03", "Baxi Heating", "Potterton", "Assure", "25 Heat", "41-592-69", "2017", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "25", "25", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "33", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.3", "98.0", "", "", "", "", "96.0"]} -{"pcdb_id": 18209, "brand_name": "Potterton", "model_name": "Assure", "model_qualifier": "30 Heat", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 30.0, "final_year_of_manufacture": null, "raw": ["018209", "000005", "0", "2017/Aug/16 11:03", "Baxi Heating", "Potterton", "Assure", "30 Heat", "41-592-70", "2017", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "30", "30", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "44", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.3", "98.0", "", "", "", "", "96.0"]} -{"pcdb_id": 18210, "brand_name": "Vaillant", "model_name": "ecoTEC plus 612", "model_qualifier": "VU 126/5-5 (H-GB) R6", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 12.4, "final_year_of_manufacture": null, "raw": ["018210", "000031", "0", "2018/Mar/21 08:22", "Vaillant", "Vaillant", "ecoTEC plus 612", "VU 126/5-5 (H-GB) R6", "41-694-20", "2017", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "12.4", "12.4", "", "", "88.6", "79.6", "", "58.1", "", "2", "", "", "102", "1", "2", "22", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0045", "", "", "", "", "", "", "", "", "88.8", "97.8", "", "", "", "", "96.1"]} -{"pcdb_id": 18211, "brand_name": "Vaillant", "model_name": "ecoTEC plus 615", "model_qualifier": "VU 156/5-5 (H-GB) R6", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 15.5, "final_year_of_manufacture": null, "raw": ["018211", "000031", "0", "2018/Mar/19 11:25", "Vaillant", "Vaillant", "ecoTEC plus 615", "VU 156/5-5 (H-GB) R6", "41-694-21", "2017", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "15.5", "15.5", "", "", "88.5", "79.5", "", "58.1", "", "2", "", "", "102", "1", "2", "28", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0045", "", "", "", "", "", "", "", "", "88.6", "97.8", "", "", "", "", "96.1"]} -{"pcdb_id": 18212, "brand_name": "Vaillant", "model_name": "ecoTEC plus 618", "model_qualifier": "VU 186/5-5 (H-GB) R6", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 18.6, "final_year_of_manufacture": null, "raw": ["018212", "000031", "0", "2019/Jan/18 11:52", "Vaillant", "Vaillant", "ecoTEC plus 618", "VU 186/5-5 (H-GB) R6", "41-694-22", "2017", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18.6", "18.6", "", "", "88.9", "79.9", "", "58.3", "", "2", "", "", "102", "1", "2", "29", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0045", "", "", "", "", "", "", "", "", "88.7", "98.7", "", "", "", "", "96.8"]} -{"pcdb_id": 18213, "brand_name": "Vaillant", "model_name": "ecoTEC plus 618", "model_qualifier": "VU 186/5-5 (P-GB) R6", "winter_efficiency_pct": 89.9, "summer_efficiency_pct": 80.9, "comparative_hot_water_efficiency_pct": 59.1, "output_kw_max": 18.6, "final_year_of_manufacture": null, "raw": ["018213", "000031", "0", "2018/Mar/19 11:25", "Vaillant", "Vaillant", "ecoTEC plus 618", "VU 186/5-5 (P-GB) R6", "41-694-23", "2017", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "18.6", "18.6", "", "", "89.9", "80.9", "", "59.1", "", "2", "0", "", "102", "1", "2", "25", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0045", "", "", "", "", "", "", "", "", "90.4", "98.5", "", "", "", "", "97.0"]} -{"pcdb_id": 18214, "brand_name": "Vaillant", "model_name": "ecoTEC plus 624", "model_qualifier": "VU 246/5-5 (H-GB) R6", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 24.7, "final_year_of_manufacture": null, "raw": ["018214", "000031", "0", "2018/Aug/20 09:30", "Vaillant", "Vaillant", "ecoTEC plus 624", "VU 246/5-5 (H-GB) R6", "41-694-24", "2017", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24.7", "24.7", "", "", "88.9", "79.9", "", "58.4", "", "2", "", "", "102", "1", "2", "25", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0045", "", "", "", "", "", "", "", "", "88.5", "98.9", "", "", "", "", "96.9"]} -{"pcdb_id": 18215, "brand_name": "Vaillant", "model_name": "ecoTEC plus 630", "model_qualifier": "VU 306/5-5 (H-GB) R6", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 30.9, "final_year_of_manufacture": null, "raw": ["018215", "000031", "0", "2018/Aug/20 09:31", "Vaillant", "Vaillant", "ecoTEC plus 630", "VU 306/5-5 (H-GB) R6", "41-694-25", "2017", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "30.9", "30.9", "", "", "88.8", "79.8", "", "58.3", "", "2", "", "", "102", "1", "2", "33", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0045", "", "", "", "", "", "", "", "", "88.5", "98.6", "", "", "", "", "96.7"]} -{"pcdb_id": 18216, "brand_name": "Vaillant", "model_name": "ecoTEC plus 630", "model_qualifier": "VU 306/5-5 (P-GB) R6", "winter_efficiency_pct": 90.0, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 59.2, "output_kw_max": 30.9, "final_year_of_manufacture": null, "raw": ["018216", "000031", "0", "2018/Mar/19 11:26", "Vaillant", "Vaillant", "ecoTEC plus 630", "VU 306/5-5 (P-GB) R6", "41-694-26", "2017", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "30.9", "30.9", "", "", "90.0", "81.0", "", "59.2", "", "2", "0", "", "102", "1", "2", "32", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0045", "", "", "", "", "", "", "", "", "90.2", "98.8", "", "", "", "", "97.2"]} -{"pcdb_id": 18217, "brand_name": "Vaillant", "model_name": "ecoTEC plus 637", "model_qualifier": "VU 386/5-5 (H-GB) R6", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 38.1, "final_year_of_manufacture": null, "raw": ["018217", "000031", "0", "2018/Aug/20 09:31", "Vaillant", "Vaillant", "ecoTEC plus 637", "VU 386/5-5 (H-GB) R6", "41-694-27", "2017", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "38.1", "38.1", "", "", "88.8", "79.8", "", "58.3", "", "2", "", "", "102", "1", "2", "45", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0045", "", "", "", "", "", "", "", "", "88.7", "98.5", "", "", "", "", "96.6"]} -{"pcdb_id": 18218, "brand_name": "Vaillant", "model_name": "ecoTEC plus 825", "model_qualifier": "VUW 196/5-5 (H-GB) R6", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 56.5, "output_kw_max": 19.6, "final_year_of_manufacture": null, "raw": ["018218", "000031", "0", "2019/Jan/18 11:51", "Vaillant", "Vaillant", "ecoTEC plus 825", "VUW 196/5-5 (H-GB) R6", "47-044-83", "2017", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "19.6", "19.6", "", "", "88.9", "80.3", "", "56.5", "", "2", "", "", "104", "1", "2", "29", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0045", "", "", "", "", "", "", "", "", "88.7", "98.7", "", "", "", "", "96.8"]} -{"pcdb_id": 18219, "brand_name": "Vaillant", "model_name": "ecoTEC plus 832", "model_qualifier": "VUW 246/5-5 (H-GB) R6", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 56.5, "output_kw_max": 24.7, "final_year_of_manufacture": null, "raw": ["018219", "000031", "0", "2019/Jan/18 11:51", "Vaillant", "Vaillant", "ecoTEC plus 832", "VUW 246/5-5 (H-GB) R6", "47-044-84", "2017", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.7", "24.7", "", "", "88.9", "80.3", "", "56.5", "", "2", "", "", "104", "1", "2", "25", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0045", "", "", "", "", "", "", "", "", "88.5", "98.9", "", "", "", "", "96.9"]} -{"pcdb_id": 18220, "brand_name": "Vaillant", "model_name": "ecoTEC plus 832", "model_qualifier": "VUW 246/5-5 (P-GB) R6", "winter_efficiency_pct": 89.9, "summer_efficiency_pct": 81.3, "comparative_hot_water_efficiency_pct": 57.2, "output_kw_max": 24.0, "final_year_of_manufacture": null, "raw": ["018220", "000031", "0", "2018/Mar/19 11:26", "Vaillant", "Vaillant", "ecoTEC plus 832", "VUW 246/5-5 (P-GB) R6", "47-044-85", "2017", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "89.9", "81.3", "", "57.2", "", "2", "0", "", "104", "1", "2", "39", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0045", "", "", "", "", "", "", "", "", "90.4", "98.5", "", "", "", "", "96.9"]} -{"pcdb_id": 18221, "brand_name": "Vaillant", "model_name": "ecoTEC plus 835", "model_qualifier": "VUW 306/5-5 (H-GB) R6", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 56.4, "output_kw_max": 30.9, "final_year_of_manufacture": null, "raw": ["018221", "000031", "0", "2019/Jan/18 11:52", "Vaillant", "Vaillant", "ecoTEC plus 835", "VUW 306/5-5 (H-GB) R6", "47-044-82", "2017", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "30.9", "30.9", "", "", "88.8", "80.2", "", "56.4", "", "2", "", "", "104", "1", "2", "33", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0045", "", "", "", "", "", "", "", "", "88.5", "98.6", "", "", "", "", "96.7"]} -{"pcdb_id": 18222, "brand_name": "Vaillant", "model_name": "ecoTEC plus 838", "model_qualifier": "VUW 286/5-5 (H-GB) R6", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 56.4, "output_kw_max": 28.9, "final_year_of_manufacture": null, "raw": ["018222", "000031", "0", "2019/Jan/18 11:52", "Vaillant", "Vaillant", "ecoTEC plus 838", "VUW 286/5-5 (H-GB) R6", "47-044-86", "2017", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28.9", "28.9", "", "", "88.8", "80.2", "", "56.4", "", "2", "", "", "104", "1", "2", "29", "3", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0045", "", "", "", "", "", "", "", "", "88.7", "98.6", "", "", "", "", "96.7"]} -{"pcdb_id": 18223, "brand_name": "Vaillant", "model_name": "ecoTEC plus 938", "model_qualifier": "VUI 286/5-5 (H-GB) R6", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 56.4, "output_kw_max": 28.9, "final_year_of_manufacture": null, "raw": ["018223", "000031", "0", "2019/Mar/11 09:21", "Vaillant", "Vaillant", "ecoTEC plus 938", "VUI 286/5-5 (H-GB) R6", "47-044-87", "2017", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28.9", "28.9", "", "", "88.8", "80.2", "", "56.4", "", "2", "", "", "104", "1", "2", "28", "3", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0045", "", "", "", "", "", "", "", "", "88.7", "98.6", "", "", "", "", "96.7"]} -{"pcdb_id": 18224, "brand_name": "Vaillant", "model_name": "ecoTEC pro 24", "model_qualifier": "VUW 246/5-3 (H-GB) R6", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 56.5, "output_kw_max": 23.5, "final_year_of_manufacture": null, "raw": ["018224", "000031", "0", "2019/Jan/18 11:52", "Vaillant", "Vaillant", "ecoTEC pro 24", "VUW 246/5-3 (H-GB) R6", "47-044-88", "2017", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "23.5", "23.5", "", "", "88.9", "80.3", "", "56.5", "", "2", "", "", "104", "1", "2", "32", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0045", "", "", "", "", "", "", "", "", "88.7", "98.7", "", "", "", "", "96.8"]} -{"pcdb_id": 18225, "brand_name": "Vaillant", "model_name": "ecoTEC pro 28", "model_qualifier": "VUW 286/5-3 (H-GB) R6", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 56.5, "output_kw_max": 24.5, "final_year_of_manufacture": null, "raw": ["018225", "000031", "0", "2019/Jan/18 11:52", "Vaillant", "Vaillant", "ecoTEC pro 28", "VUW 286/5-3 (H-GB) R6", "47-044-89", "2017", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.5", "24.5", "", "", "88.9", "80.3", "", "56.5", "", "2", "", "", "104", "1", "2", "32", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0045", "", "", "", "", "", "", "", "", "88.7", "98.7", "", "", "", "", "96.8"]} -{"pcdb_id": 18226, "brand_name": "Vaillant", "model_name": "ecoTEC pro 28", "model_qualifier": "VUW 286/5-3 (P-GB)", "winter_efficiency_pct": 90.1, "summer_efficiency_pct": 81.5, "comparative_hot_water_efficiency_pct": 57.3, "output_kw_max": 24.0, "final_year_of_manufacture": null, "raw": ["018226", "000031", "0", "2018/Mar/19 11:27", "Vaillant", "Vaillant", "ecoTEC pro 28", "VUW 286/5-3 (P-GB)", "47-044-89", "2017", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "90.1", "81.5", "", "57.3", "", "2", "0", "", "104", "1", "2", "32", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0045", "", "", "", "", "", "", "", "", "90.4", "99.1", "", "", "", "", "97.4"]} -{"pcdb_id": 18227, "brand_name": "Glow-worm", "model_name": "EASICOM 3", "model_qualifier": "24c-A (H-GB)", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.4, "comparative_hot_water_efficiency_pct": 56.6, "output_kw_max": 20.4, "final_year_of_manufacture": null, "raw": ["018227", "000207", "0", "2018/Mar/19 11:40", "Glow-worm", "Glow-worm", "EASICOM 3", "24c-A (H-GB)", "47-019-50", "2017", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "20.4", "20.4", "", "", "89.0", "80.4", "", "56.6", "", "2", "", "", "104", "1", "2", "27", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0085", "", "", "", "", "", "", "", "", "89.1", "98.9", "", "", "", "", "97.1"]} -{"pcdb_id": 18228, "brand_name": "Glow-worm", "model_name": "EASICOM 3", "model_qualifier": "28c-A (H-GB)", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.4, "comparative_hot_water_efficiency_pct": 56.5, "output_kw_max": 25.0, "final_year_of_manufacture": null, "raw": ["018228", "000207", "0", "2019/May/09 11:58", "Glow-worm", "Glow-worm", "EASICOM 3", "28c-A (H-GB)", "47-019-51", "2017", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "25", "25", "", "", "89.0", "80.4", "", "56.5", "", "2", "", "", "104", "1", "2", "29", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0085", "", "", "", "", "", "", "", "", "89.0", "98.8", "", "", "", "", "97.0"]} -{"pcdb_id": 18229, "brand_name": "Glow-worm", "model_name": "ULTIMATE 3", "model_qualifier": "30c-A (H-GB)", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.4, "comparative_hot_water_efficiency_pct": 56.5, "output_kw_max": 25.0, "final_year_of_manufacture": null, "raw": ["018229", "000207", "0", "2019/May/09 12:01", "Glow-worm", "Glow-worm", "ULTIMATE 3", "30c-A (H-GB)", "47-019-55", "2017", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "25", "25", "", "", "89.0", "80.4", "", "56.5", "", "2", "", "", "104", "1", "2", "29", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0085", "", "", "", "", "", "", "", "", "89.0", "98.8", "", "", "", "", "97.0"]} -{"pcdb_id": 18230, "brand_name": "Glow-worm", "model_name": "ULTIMATE 3", "model_qualifier": "35c-A (H-GB)", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 56.6, "output_kw_max": 25.0, "final_year_of_manufacture": null, "raw": ["018230", "000207", "0", "2019/May/09 12:02", "Glow-worm", "Glow-worm", "ULTIMATE 3", "35c-A (H-GB)", "47-019-57", "2017", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "25", "25", "", "", "89.1", "80.5", "", "56.6", "", "2", "", "", "104", "1", "2", "27", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0085", "", "", "", "", "", "", "", "", "89.5", "99.0", "", "", "", "", "97.2"]} -{"pcdb_id": 18231, "brand_name": "Glow-worm", "model_name": "ULTIMATE 3", "model_qualifier": "25s-A (H-GB)", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 25.0, "final_year_of_manufacture": null, "raw": ["018231", "000207", "0", "2019/May/09 12:04", "Glow-worm", "Glow-worm", "ULTIMATE 3", "25s-A (H-GB)", "41-019-51", "2017", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "25", "25", "", "", "89.0", "80.0", "", "58.4", "", "2", "", "", "102", "1", "2", "29", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0085", "", "", "", "", "", "", "", "", "89.0", "98.8", "", "", "", "", "97.0"]} -{"pcdb_id": 18232, "brand_name": "Glow-worm", "model_name": "ULTIMATE 3", "model_qualifier": "25r-A (H-GB)", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 25.2, "final_year_of_manufacture": null, "raw": ["018232", "000207", "0", "2022/May/10 10:35", "Glow-worm", "Glow-worm", "ULTIMATE 3", "25r-A (H-GB)", "41-019-52", "2017", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "25.2", "25.2", "", "", "89.0", "80.0", "", "58.4", "", "2", "", "", "102", "1", "2", "29", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0085", "", "", "", "", "", "", "", "", "89.0", "98.8", "", "", "", "", "97.0"]} -{"pcdb_id": 18233, "brand_name": "Glow-worm", "model_name": "BETACOM 4", "model_qualifier": "24c-A (H-GB)", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.4, "comparative_hot_water_efficiency_pct": 56.6, "output_kw_max": 20.4, "final_year_of_manufacture": null, "raw": ["018233", "000207", "0", "2018/Mar/19 11:40", "Glow-worm", "Glow-worm", "BETACOM 4", "24c-A (H-GB)", "47-019-52", "2017", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "20.4", "20.4", "", "", "89.0", "80.4", "", "56.6", "", "2", "", "", "104", "1", "2", "27", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0085", "", "", "", "", "", "", "", "", "89.1", "98.9", "", "", "", "", "97.1"]} -{"pcdb_id": 18234, "brand_name": "Glow-worm", "model_name": "BETACOM 4", "model_qualifier": "30c-A (H-GB)", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.4, "comparative_hot_water_efficiency_pct": 56.5, "output_kw_max": 25.0, "final_year_of_manufacture": null, "raw": ["018234", "000207", "0", "2019/May/09 12:07", "Glow-worm", "Glow-worm", "BETACOM 4", "30c-A (H-GB)", "47-019-53", "2017", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "25", "25", "", "", "89.0", "80.4", "", "56.5", "", "2", "", "", "104", "1", "2", "29", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0085", "", "", "", "", "", "", "", "", "89.0", "98.8", "", "", "", "", "97.0"]} -{"pcdb_id": 18236, "brand_name": "Ariston", "model_name": "CLAS SYSTEM ONE 18", "model_qualifier": "", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 17.6, "final_year_of_manufacture": null, "raw": ["018236", "000080", "0", "2018/Apr/09 11:33", "Ariston Thermo S.p.A", "Ariston", "CLAS SYSTEM ONE 18", "", "3301046", "2017", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "17.6", "17.6", "", "", "88.7", "79.7", "", "58.2", "", "2", "", "", "102", "1", "2", "24", "4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0805", "", "", "", "", "", "", "", "", "87.9", "98.6", "", "", "", "", "96.5"]} -{"pcdb_id": 18237, "brand_name": "Ariston", "model_name": "CLAS ONE 24", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 86.6, "comparative_hot_water_efficiency_pct": 75.2, "output_kw_max": 21.4, "final_year_of_manufacture": null, "raw": ["018237", "000080", "0", "2020/Jan/22 13:16", "Ariston Thermo S.p.A", "Ariston", "CLAS ONE 24", "", "3301043", "2017", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "21.4", "21.4", "", "", "88.8", "86.6", "", "75.2", "", "2", "", "", "104", "1", "2", "30", "4", "0", "", "", "", "0", "", "", "", "", "1", "7.006", "0.121", "0.003", "0.87401", "", "", "", "", "", "", "", "", "0805", "", "", "", "", "", "", "", "", "87.8", "98.9", "", "", "", "", "96.8"]} -{"pcdb_id": 18238, "brand_name": "Ariston", "model_name": "CLAS SYSTEM ONE 24", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 21.4, "final_year_of_manufacture": null, "raw": ["018238", "000080", "0", "2018/Apr/09 11:36", "Ariston Thermo S.p.A", "Ariston", "CLAS SYSTEM ONE 24", "", "3301047", "2017", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "21.4", "21.4", "", "", "88.8", "79.8", "", "58.3", "", "2", "", "", "102", "1", "2", "30", "4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0805", "", "", "", "", "", "", "", "", "87.8", "98.9", "", "", "", "", "96.8"]} -{"pcdb_id": 18239, "brand_name": "Ariston", "model_name": "CLAS NET ONE 24", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 86.6, "comparative_hot_water_efficiency_pct": 75.2, "output_kw_max": 21.4, "final_year_of_manufacture": null, "raw": ["018239", "000080", "0", "2020/Jan/22 13:16", "Ariston Thermo S.p.A", "Ariston", "CLAS NET ONE 24", "", "3301049", "2017", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "21.4", "21.4", "", "", "88.8", "86.6", "", "75.2", "", "2", "", "", "104", "1", "2", "30", "4", "0", "", "", "", "0", "", "", "", "", "1", "7.006", "0.121", "0.003", "0.87401", "", "", "", "", "", "", "", "", "0805", "", "", "", "", "", "", "", "", "87.8", "98.9", "", "", "", "", "96.8"]} -{"pcdb_id": 18240, "brand_name": "Ariston", "model_name": "E-COMBI ONE 24", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 86.6, "comparative_hot_water_efficiency_pct": 75.2, "output_kw_max": 21.4, "final_year_of_manufacture": null, "raw": ["018240", "000080", "0", "2020/Jan/22 13:17", "Ariston Thermo S.p.A", "Ariston", "E-COMBI ONE 24", "", "3301131", "2017", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "21.4", "21.4", "", "", "88.8", "86.6", "", "75.2", "", "2", "", "", "104", "1", "2", "30", "4", "0", "", "", "", "0", "", "", "", "", "1", "7.006", "0.121", "0.003", "0.87401", "", "", "", "", "", "", "", "", "0805", "", "", "", "", "", "", "", "", "87.8", "98.9", "", "", "", "", "96.8"]} -{"pcdb_id": 18241, "brand_name": "Ariston", "model_name": "E-SYSTEM ONE 24", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 21.4, "final_year_of_manufacture": null, "raw": ["018241", "000080", "0", "2018/Apr/09 11:41", "Ariston Thermo S.p.A", "Ariston", "E-SYSTEM ONE 24", "", "3301056", "2017", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "21.4", "21.4", "", "", "88.8", "79.8", "", "58.3", "", "2", "", "", "102", "1", "2", "30", "4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0805", "", "", "", "", "", "", "", "", "87.8", "98.9", "", "", "", "", "96.8"]} -{"pcdb_id": 18242, "brand_name": "Ariston", "model_name": "CLAS ONE 30", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 86.8, "comparative_hot_water_efficiency_pct": 72.7, "output_kw_max": 27.4, "final_year_of_manufacture": null, "raw": ["018242", "000080", "0", "2020/Jan/22 13:17", "Ariston Thermo S.p.A", "Ariston", "CLAS ONE 30", "", "3301044", "2017", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "27.4", "27.4", "", "", "88.8", "86.8", "", "72.7", "", "2", "", "", "104", "1", "2", "39", "4", "0", "", "", "", "0", "", "", "", "", "1", "7.239", "0.14", "0.007", "1.08414", "", "", "", "", "", "", "", "", "0805", "", "", "", "", "", "", "", "", "88.2", "98.7", "", "", "", "", "96.7"]} -{"pcdb_id": 18243, "brand_name": "Ariston", "model_name": "CLAS NET ONE 30", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 86.8, "comparative_hot_water_efficiency_pct": 72.7, "output_kw_max": 27.4, "final_year_of_manufacture": null, "raw": ["018243", "000080", "0", "2020/Jan/22 13:17", "Ariston Thermo S.p.A", "Ariston", "CLAS NET ONE 30", "", "3301050", "2017", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "27.4", "27.4", "", "", "88.8", "86.8", "", "72.7", "", "2", "", "", "104", "1", "2", "39", "4", "0", "", "", "", "0", "", "", "", "", "1", "7.239", "0.14", "0.007", "1.08414", "", "", "", "", "", "", "", "", "0805", "", "", "", "", "", "", "", "", "88.2", "98.7", "", "", "", "", "96.7"]} -{"pcdb_id": 18244, "brand_name": "Ariston", "model_name": "CLAS SYSTEM ONE 30", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 27.4, "final_year_of_manufacture": null, "raw": ["018244", "000080", "0", "2018/Apr/09 12:16", "Ariston Thermo S.p.A", "Ariston", "CLAS SYSTEM ONE 30", "", "3301048", "2017", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "27.4", "27.4", "", "", "88.8", "79.8", "", "58.3", "", "2", "", "", "102", "1", "2", "39", "4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0805", "", "", "", "", "", "", "", "", "88.2", "98.7", "", "", "", "", "96.7"]} -{"pcdb_id": 18245, "brand_name": "Ariston", "model_name": "E-COMBI ONE 30", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 86.8, "comparative_hot_water_efficiency_pct": 72.7, "output_kw_max": 27.4, "final_year_of_manufacture": null, "raw": ["018245", "000080", "0", "2020/Jan/22 13:17", "Ariston Thermo S.p.A", "Ariston", "E-COMBI ONE 30", "", "3301132", "2017", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "27.4", "27.4", "", "", "88.8", "86.8", "", "72.7", "", "2", "", "", "104", "1", "2", "39", "4", "0", "", "", "", "0", "", "", "", "", "1", "7.239", "0.14", "0.007", "1.08414", "", "", "", "", "", "", "", "", "0805", "", "", "", "", "", "", "", "", "88.2", "98.7", "", "", "", "", "96.7"]} -{"pcdb_id": 18246, "brand_name": "Ariston", "model_name": "E-SYSTEM ONE 30", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 27.4, "final_year_of_manufacture": null, "raw": ["018246", "000080", "0", "2018/Apr/09 12:18", "Ariston Thermo S.p.A", "Ariston", "E-SYSTEM ONE 30", "", "3301057", "2017", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "27.4", "27.4", "", "", "88.8", "79.8", "", "58.3", "", "2", "", "", "102", "1", "2", "39", "4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0805", "", "", "", "", "", "", "", "", "88.2", "98.7", "", "", "", "", "96.7"]} -{"pcdb_id": 18247, "brand_name": "Ariston", "model_name": "CLAS ONE 38", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 86.6, "comparative_hot_water_efficiency_pct": 68.2, "output_kw_max": 30.2, "final_year_of_manufacture": null, "raw": ["018247", "000080", "0", "2020/Jan/22 13:17", "Ariston Thermo S.p.A", "Ariston", "CLAS ONE 38", "", "3301045", "2017", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "30.2", "30.2", "", "", "88.8", "86.6", "", "68.2", "", "2", "", "", "104", "1", "2", "35", "4", "0", "", "", "", "0", "", "", "", "", "1", "7.727", "0.144", "0.006", "1.54975", "", "", "", "", "", "", "", "", "0805", "", "", "", "", "", "", "", "", "87.8", "98.8", "", "", "", "", "96.8"]} -{"pcdb_id": 18248, "brand_name": "Ariston", "model_name": "CLAS NET ONE 38", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 86.6, "comparative_hot_water_efficiency_pct": 68.2, "output_kw_max": 30.2, "final_year_of_manufacture": null, "raw": ["018248", "000080", "0", "2020/Jan/22 13:17", "Ariston Thermo S.p.A", "Ariston", "CLAS NET ONE 38", "", "3301051", "2017", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "30.2", "30.2", "", "", "88.8", "86.6", "", "68.2", "", "2", "", "", "104", "1", "2", "35", "4", "0", "", "", "", "0", "", "", "", "", "1", "7.727", "0.144", "0.006", "1.54975", "", "", "", "", "", "", "", "", "0805", "", "", "", "", "", "", "", "", "87.8", "98.8", "", "", "", "", "96.8"]} -{"pcdb_id": 18249, "brand_name": "Vokera BY RIELLO", "model_name": "evolve", "model_qualifier": "24C", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 86.7, "comparative_hot_water_efficiency_pct": 77.0, "output_kw_max": 17.6, "final_year_of_manufacture": null, "raw": ["018249", "000011", "0", "2019/Aug/15 08:24", "Vokera", "Vokera BY RIELLO", "evolve", "24C", "20119408", "2017", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "17.6", "17.6", "", "", "88.9", "86.7", "", "77.0", "", "2", "", "", "104", "1", "2", "28", "3", "0", "", "", "0", "0", "", "", "", "", "1", "6.835", "0.109", "0.004", "0.71045", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "88.1", "98.9", "", "", "", "", "96.9"]} -{"pcdb_id": 18250, "brand_name": "Baxi", "model_name": "630 Combi", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 86.7, "comparative_hot_water_efficiency_pct": 79.3, "output_kw_max": 20.0, "final_year_of_manufacture": null, "raw": ["018250", "000005", "0", "2020/Jan/22 13:17", "Baxi", "Baxi", "630 Combi", "", "GC No 47-077-29", "2017", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "20", "20", "", "", "88.4", "86.7", "", "79.3", "", "2", "", "", "104", "1", "2", "78", "3", "0", "", "", "", "0", "", "", "", "", "1", "6.641", "0.105", "0.0009", "0.53976", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "88.0", "97.8", "", "", "", "", "95.9"]} -{"pcdb_id": 18251, "brand_name": "Baxi", "model_name": "624 Combi", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 86.7, "comparative_hot_water_efficiency_pct": 80.2, "output_kw_max": 20.0, "final_year_of_manufacture": null, "raw": ["018251", "000005", "0", "2020/Jan/22 13:17", "Baxi", "Baxi", "624 Combi", "", "GC No 47-077-28", "2017", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "20", "20", "", "", "88.4", "86.7", "", "80.2", "", "2", "", "", "104", "1", "2", "68", "3", "0", "", "", "", "0", "", "", "", "", "1", "6.563", "0.102", "0.0004", "0.46731", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "88.0", "97.8", "", "", "", "", "95.9"]} -{"pcdb_id": 18252, "brand_name": "Vokera BY RIELLO", "model_name": "evolve", "model_qualifier": "18S", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 17.6, "final_year_of_manufacture": null, "raw": ["018252", "000011", "0", "2019/Aug/15 08:45", "Vokera", "Vokera BY RIELLO", "evolve", "18S", "20127447", "2017", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "17.6", "17.6", "", "", "88.9", "79.9", "", "58.3", "", "2", "", "", "102", "1", "2", "28", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "88.1", "98.9", "", "", "", "", "96.9"]} -{"pcdb_id": 18253, "brand_name": "Vokera BY RIELLO", "model_name": "evolve", "model_qualifier": "24S", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 23.54, "final_year_of_manufacture": null, "raw": ["018253", "000011", "0", "2019/Aug/15 08:59", "Vokera", "Vokera BY RIELLO", "evolve", "24S", "20127448", "2017", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "23.54", "23.54", "", "", "88.9", "79.9", "", "58.4", "", "2", "", "", "102", "1", "2", "37", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "88.4", "98.9", "", "", "", "", "96.9"]} -{"pcdb_id": 18254, "brand_name": "Vokera BY RIELLO", "model_name": "evolve", "model_qualifier": "28C", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 86.8, "comparative_hot_water_efficiency_pct": 77.0, "output_kw_max": 23.54, "final_year_of_manufacture": null, "raw": ["018254", "000011", "0", "2019/Aug/15 09:01", "Vokera", "Vokera BY RIELLO", "evolve", "28C", "20119409", "2017", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "23.54", "23.54", "", "", "88.9", "86.8", "", "77.0", "", "2", "", "", "104", "1", "2", "37", "3", "0", "", "", "", "0", "", "", "", "", "1", "6.837", "0.109", "0.0035", "0.72201", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "88.4", "98.9", "", "", "", "", "96.9"]} -{"pcdb_id": 18255, "brand_name": "Vokera BY RIELLO", "model_name": "evolve", "model_qualifier": "32C", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 86.8, "comparative_hot_water_efficiency_pct": 77.0, "output_kw_max": 29.37, "final_year_of_manufacture": null, "raw": ["018255", "000011", "0", "2019/Aug/15 09:04", "Vokera", "Vokera BY RIELLO", "evolve", "32C", "20131015", "2017", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "29.37", "29.37", "", "", "88.8", "86.8", "", "77.0", "", "2", "", "", "104", "1", "2", "40", "3", "0", "", "", "", "0", "", "", "", "", "1", "6.838", "0.116", "0.003", "0.72142", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "88.2", "98.7", "", "", "", "", "96.7"]} -{"pcdb_id": 18256, "brand_name": "Warmflow", "model_name": "UTILITY COMBI 90 HE ECO", "model_qualifier": "UC90HEE", "winter_efficiency_pct": 87.5, "summer_efficiency_pct": 81.4, "comparative_hot_water_efficiency_pct": 52.4, "output_kw_max": 27.0, "final_year_of_manufacture": null, "raw": ["018256", "000063", "0", "2024/Jan/31 10:17", "Warmflow Engineering", "Warmflow", "UTILITY COMBI 90 HE ECO", "UC90HEE", "", "2016", "current", "4", "1", "1", "2", "0", "", "", "2", "3", "2", "27", "27", "", "", "87.5", "81.4", "", "52.4", "", "2", "", "", "203", "1", "1", "200", "0", "1", "2", "", "50", "0", "50", "2", "55", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.6", "93.5", "", "", "", "", "93.0"]} -{"pcdb_id": 18257, "brand_name": "Warmflow", "model_name": "UTILITY COMBI 120 HE ECO", "model_qualifier": "UC120HEE", "winter_efficiency_pct": 86.9, "summer_efficiency_pct": 80.9, "comparative_hot_water_efficiency_pct": 52.1, "output_kw_max": 33.0, "final_year_of_manufacture": null, "raw": ["018257", "000063", "0", "2024/Jan/31 10:17", "Warmflow Engineering", "Warmflow", "UTILITY COMBI 120 HE ECO", "UC120HEE", "", "2016", "current", "4", "1", "1", "2", "0", "", "", "2", "3", "2", "33", "33", "", "", "86.9", "80.9", "", "52.1", "", "2", "", "", "203", "1", "1", "100", "0", "1", "2", "", "50", "0", "50", "2", "55", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "89.5", "92.6", "", "", "", "", "92.0"]} -{"pcdb_id": 18258, "brand_name": "Warmflow", "model_name": "KABIN PAK COMBI 70 HE ECO", "model_qualifier": "KC70HEE", "winter_efficiency_pct": 87.5, "summer_efficiency_pct": 81.5, "comparative_hot_water_efficiency_pct": 52.4, "output_kw_max": 21.0, "final_year_of_manufacture": null, "raw": ["018258", "000063", "0", "2024/Jan/31 10:17", "Warmflow Engineering", "Warmflow", "KABIN PAK COMBI 70 HE ECO", "KC70HEE", "", "2016", "current", "4", "1", "2", "2", "0", "", "", "2", "3", "2", "21", "21", "", "", "87.5", "81.5", "", "52.4", "", "2", "", "", "203", "1", "1", "200", "0", "1", "2", "", "50", "0", "50", "2", "55", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.3", "93.3", "", "", "", "", "92.9"]} -{"pcdb_id": 18259, "brand_name": "Warmflow", "model_name": "KABIN PAK COMBI 90 HE ECO", "model_qualifier": "KC90HEE", "winter_efficiency_pct": 87.5, "summer_efficiency_pct": 81.4, "comparative_hot_water_efficiency_pct": 52.4, "output_kw_max": 27.0, "final_year_of_manufacture": null, "raw": ["018259", "000063", "0", "2024/Jan/31 10:17", "Warmflow Engineering", "Warmflow", "KABIN PAK COMBI 90 HE ECO", "KC90HEE", "", "2016", "current", "4", "1", "2", "2", "0", "", "", "2", "3", "2", "27", "27", "", "", "87.5", "81.4", "", "52.4", "", "2", "", "", "203", "1", "1", "200", "0", "1", "2", "", "50", "0", "50", "2", "55", "", "0", "", "", "", "", "", "", "", "", "", "0", "0", "", "0003", "", "", "", "", "", "", "", "", "90.6", "93.5", "", "", "", "", "93.0"]} -{"pcdb_id": 18260, "brand_name": "Warmflow", "model_name": "KABIN PAK COMBI 120 HE ECO", "model_qualifier": "KC120HEE", "winter_efficiency_pct": 86.9, "summer_efficiency_pct": 80.9, "comparative_hot_water_efficiency_pct": 52.1, "output_kw_max": 33.0, "final_year_of_manufacture": null, "raw": ["018260", "000063", "0", "2024/Jan/31 10:17", "Warmflow Engineering", "Warmflow", "KABIN PAK COMBI 120 HE ECO", "KC120HEE", "", "2016", "current", "4", "1", "2", "2", "0", "", "", "2", "3", "2", "33", "33", "", "", "86.9", "80.9", "", "52.1", "", "2", "", "", "203", "1", "1", "100", "0", "1", "2", "", "50", "0", "50", "2", "55", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "89.5", "92.6", "", "", "", "", "92.0"]} -{"pcdb_id": 18261, "brand_name": "Ferroli", "model_name": "i25", "model_qualifier": "", "winter_efficiency_pct": 87.4, "summer_efficiency_pct": 86.2, "comparative_hot_water_efficiency_pct": 88.1, "output_kw_max": 24.1, "final_year_of_manufacture": null, "raw": ["018261", "000097", "0", "2017/Dec/18 14:17", "Ferroli", "Ferroli", "i25", "", "GC No 47-267-64", "2017", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.1", "24.1", "", "", "87.4", "86.2", "", "88.1", "", "2", "", "", "104", "1", "2", "55", "3", "0", "", "", "", "0", "", "", "", "", "1", "5.976", "0.11", "0.004", "0.0", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "86.6", "95.8", "", "", "", "", "94.0"]} -{"pcdb_id": 18262, "brand_name": "Ferroli", "model_name": "i29", "model_qualifier": "", "winter_efficiency_pct": 87.4, "summer_efficiency_pct": 86.3, "comparative_hot_water_efficiency_pct": 88.1, "output_kw_max": 27.0, "final_year_of_manufacture": null, "raw": ["018262", "000097", "0", "2017/Dec/18 14:17", "Ferroli", "Ferroli", "i29", "", "GC No 47-267-65", "2017", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "27", "27", "", "", "87.4", "86.3", "", "88.1", "", "2", "", "", "104", "1", "2", "75", "3", "0", "", "", "", "0", "", "", "", "", "1", "5.976", "0.11", "0.004", "0.0", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "86.8", "95.8", "", "", "", "", "94.1"]} -{"pcdb_id": 18263, "brand_name": "EUROTERM", "model_name": "E25", "model_qualifier": "", "winter_efficiency_pct": 87.4, "summer_efficiency_pct": 86.2, "comparative_hot_water_efficiency_pct": 88.1, "output_kw_max": 24.1, "final_year_of_manufacture": null, "raw": ["018263", "000097", "0", "2017/Dec/18 14:17", "Ferroli", "EUROTERM", "E25", "", "GC No 47-267-69", "2017", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.1", "24.1", "", "", "87.4", "86.2", "", "88.1", "", "2", "", "", "104", "1", "2", "55", "3", "0", "", "", "", "0", "", "", "", "", "1", "5.976", "0.11", "0.004", "0.0", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "86.6", "95.8", "", "", "", "", "94.0"]} -{"pcdb_id": 18264, "brand_name": "EUROTERM", "model_name": "E29", "model_qualifier": "", "winter_efficiency_pct": 87.4, "summer_efficiency_pct": 86.3, "comparative_hot_water_efficiency_pct": 88.1, "output_kw_max": 27.0, "final_year_of_manufacture": null, "raw": ["018264", "000097", "0", "2017/Dec/18 14:18", "Ferroli", "EUROTERM", "E29", "", "GC No 47-267-70", "2017", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "27", "27", "", "", "87.4", "86.3", "", "88.1", "", "2", "", "", "104", "1", "2", "82", "3", "0", "", "", "", "0", "", "", "", "", "1", "5.976", "0.011", "0.004", "0.0", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "86.8", "95.8", "", "", "", "", "94.1"]} -{"pcdb_id": 18265, "brand_name": "Sime", "model_name": "MURELLE PRO HE 35 MkII", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 86.8, "comparative_hot_water_efficiency_pct": 68.4, "output_kw_max": 30.0, "final_year_of_manufacture": 2019, "raw": ["018265", "000213", "0", "2019/Feb/28 13:17", "Fonderie Sime S.p.A.", "Sime", "MURELLE PRO HE 35 MkII", "", "8114248", "2017", "2019", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "30", "30", "", "", "88.4", "86.8", "", "68.4", "", "2", "", "", "104", "1", "2", "47", "3", "0", "", "", "", "0", "", "", "", "", "1", "7.702", "0.237", "0.005", "1.54919", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.5", "97.7", "", "", "", "", "95.9"]} -{"pcdb_id": 18266, "brand_name": "Vaillant", "model_name": "ecoTEC sustain 24", "model_qualifier": "VUW 246/7-2 (H-GB)", "winter_efficiency_pct": 89.9, "summer_efficiency_pct": 81.3, "comparative_hot_water_efficiency_pct": 57.1, "output_kw_max": 18.5, "final_year_of_manufacture": null, "raw": ["018266", "000031", "0", "2017/Dec/13 09:05", "Vaillant", "Vaillant", "ecoTEC sustain 24", "VUW 246/7-2 (H-GB)", "47-044-79", "2017", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "18.5", "18.5", "", "", "89.9", "81.3", "", "57.1", "", "2", "0", "", "104", "1", "2", "19", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.2", "98.8", "", "", "", "", "97.0"]} -{"pcdb_id": 18267, "brand_name": "Vaillant", "model_name": "ecoTEC sustain 28", "model_qualifier": "VUW 286/7-2 (H-GB)", "winter_efficiency_pct": 89.8, "summer_efficiency_pct": 81.2, "comparative_hot_water_efficiency_pct": 57.1, "output_kw_max": 18.5, "final_year_of_manufacture": null, "raw": ["018267", "000031", "0", "2017/Dec/13 09:05", "Vaillant", "Vaillant", "ecoTEC sustain 28", "VUW 286/7-2 (H-GB)", "47-044-80", "2017", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "18.5", "18.5", "", "", "89.8", "81.2", "", "57.1", "", "2", "0", "", "104", "1", "2", "23", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.3", "98.6", "", "", "", "", "96.9"]} -{"pcdb_id": 18268, "brand_name": "Vaillant", "model_name": "ecoTEC sustain 34", "model_qualifier": "VUW 346/7-2 (H-GB)", "winter_efficiency_pct": 89.8, "summer_efficiency_pct": 81.2, "comparative_hot_water_efficiency_pct": 57.1, "output_kw_max": 18.5, "final_year_of_manufacture": null, "raw": ["018268", "000031", "0", "2017/Dec/13 09:06", "Vaillant", "Vaillant", "ecoTEC sustain 34", "VUW 346/7-2 (H-GB)", "47-044-81", "2017", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "18.5", "18.5", "", "", "89.8", "81.2", "", "57.1", "", "2", "0", "", "104", "1", "2", "13", "3", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.6", "98.5", "", "", "", "", "96.8"]} -{"pcdb_id": 18269, "brand_name": "Alpha", "model_name": "InTec 40 GS2", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 98.9, "comparative_hot_water_efficiency_pct": 81.0, "output_kw_max": 28.0, "final_year_of_manufacture": null, "raw": ["018269", "000001", "3", "2021/Nov/29 20:19", "Alpha Therm", "Alpha", "InTec 40 GS2", "", "3.028276", "2017", "current", "1", "2", "1", "2", "1", "313", "060041", "2", "2", "2", "28.0", "28.0", "", "", "88.3", "98.9", "", "81.0", "", "2", "", "", "104", "1", "2", "37", "6", "0", "", "", "", "0", "", "", "", "", "2", "6.5", "0.208", "0.0035", "0.42069", "11.79", "0.23", "0.0015", "1.1267", "0.00002", "", "", "", "1005", "", "", "", "", "", "", "", "", "89.4", "97.0", "", "", "", "", "95.6"]} -{"pcdb_id": 18270, "brand_name": "Potterton", "model_name": "Titanium", "model_qualifier": "12 Heat", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 13.0, "final_year_of_manufacture": null, "raw": ["018270", "000005", "0", "2017/Dec/13 17:10", "Baxi Heating UK", "Potterton", "Titanium", "12 Heat", "41-592-61", "2017", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "13.0", "13.0", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "17", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.3", "98.0", "", "", "", "", "96.0"]} -{"pcdb_id": 18271, "brand_name": "Potterton", "model_name": "Titanium", "model_qualifier": "15 Heat", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 16.0, "final_year_of_manufacture": null, "raw": ["018271", "000005", "0", "2017/Dec/13 17:10", "Baxi Heating UK", "Potterton", "Titanium", "15 Heat", "41-592-62", "2017", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "16.0", "16.0", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "20", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.3", "98.0", "", "", "", "", "96.0"]} -{"pcdb_id": 18272, "brand_name": "Potterton", "model_name": "Titanium", "model_qualifier": "18 Heat", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 19.0, "final_year_of_manufacture": null, "raw": ["018272", "000005", "0", "2017/Dec/13 17:12", "Baxi Heating UK", "Potterton", "Titanium", "18 Heat", "41-592-63", "2017", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "19.0", "19.0", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "23", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.3", "98.0", "", "", "", "", "96.0"]} -{"pcdb_id": 18273, "brand_name": "Potterton", "model_name": "Titanium", "model_qualifier": "24 Heat", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 25.0, "final_year_of_manufacture": null, "raw": ["018273", "000005", "0", "2017/Dec/13 17:14", "Baxi Heating UK", "Potterton", "Titanium", "24 Heat", "41-592-64", "2017", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "25.0", "25.0", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "33", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.3", "98.0", "", "", "", "", "96.0"]} -{"pcdb_id": 18274, "brand_name": "Potterton", "model_name": "Titanium", "model_qualifier": "30 Heat", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 30.0, "final_year_of_manufacture": null, "raw": ["018274", "000005", "0", "2017/Dec/13 17:14", "Baxi Heating UK", "Potterton", "Titanium", "30 Heat", "41-592-65", "2017", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "30.0", "30.0", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "44", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.3", "98.0", "", "", "", "", "96.0"]} -{"pcdb_id": 18275, "brand_name": "Ideal", "model_name": "Exclusive", "model_qualifier": "24", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 71.7, "output_kw_max": 24.2, "final_year_of_manufacture": null, "raw": ["018275", "000008", "0", "2017/Nov/15 13:17", "Ideal Boilers", "Ideal", "Exclusive", "24", "47-349-41", "2017", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "88.3", "87.3", "", "71.7", "", "2", "", "", "104", "1", "2", "42", "5", "0", "", "", "", "0", "", "", "", "", "1", "7.348", "0.11", "0.0022", "1.2604", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "", "", "", "", "89.8", "96.9", "", "", "", "", "95.5"]} -{"pcdb_id": 18276, "brand_name": "Ideal", "model_name": "Exclusive", "model_qualifier": "30", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 71.4, "output_kw_max": 24.2, "final_year_of_manufacture": null, "raw": ["018276", "000008", "0", "2017/Nov/15 13:17", "Ideal Boilers", "Ideal", "Exclusive", "30", "47-349-42", "2017", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "88.4", "87.3", "", "71.4", "", "2", "", "", "104", "1", "2", "32", "5", "0", "", "", "", "0", "", "", "", "", "1", "7.371", "0.109", "0.0023", "1.28692", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "", "", "", "", "90.0", "96.9", "", "", "", "", "95.6"]} -{"pcdb_id": 18277, "brand_name": "Ideal", "model_name": "Exclusive", "model_qualifier": "35", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 72.1, "output_kw_max": 24.2, "final_year_of_manufacture": null, "raw": ["018277", "000008", "0", "2017/Nov/15 13:18", "Ideal Boilers", "Ideal", "Exclusive", "35", "47-349-43", "2017", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "88.3", "87.3", "", "72.1", "", "2", "", "", "104", "1", "2", "29", "5", "0", "", "", "", "0", "", "", "", "", "1", "7.307", "0.108", "0.0023", "1.2201", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "", "", "", "", "89.8", "96.9", "", "", "", "", "95.5"]} -{"pcdb_id": 18278, "brand_name": "Baxi", "model_name": "EcoBlue Advance", "model_qualifier": "21 Heat ErP", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 21.0, "final_year_of_manufacture": null, "raw": ["018278", "000005", "0", "2018/Jan/11 14:04", "Baxi Heating UK", "Baxi", "EcoBlue Advance", "21 Heat ErP", "41-470-55", "2017", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "21.0", "21.0", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "25", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.3", "98.0", "", "", "", "", "96.0"]} -{"pcdb_id": 18280, "brand_name": "Firebird", "model_name": "Enviromax Combi HE", "model_qualifier": "20kW", "winter_efficiency_pct": 89.3, "summer_efficiency_pct": 83.4, "comparative_hot_water_efficiency_pct": 45.3, "output_kw_max": 20.0, "final_year_of_manufacture": null, "raw": ["018280", "000047", "0", "2024/Jan/31 10:17", "Firebird Heating Solutions Ltd", "Firebird", "Enviromax Combi HE", "20kW", "", "2017", "current", "4", "1", "1", "2", "0", "", "", "2", "2", "1", "20", "20", "", "", "89.3", "83.4", "", "45.3", "", "2", "", "", "203", "1", "1", "", "", "1", "2", "0", "44.02", "0", "25", "1", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "92.8", "97.4", "", "", "", "", "96.5"]} -{"pcdb_id": 18281, "brand_name": "Firebird", "model_name": "Enviromax Combi HE", "model_qualifier": "26kW", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 83.2, "comparative_hot_water_efficiency_pct": 45.2, "output_kw_max": 26.0, "final_year_of_manufacture": null, "raw": ["018281", "000047", "0", "2024/Jan/31 10:17", "Firebird Heating Solutions Ltd", "Firebird", "Enviromax Combi HE", "26kW", "", "2017", "current", "4", "1", "1", "2", "0", "", "", "2", "2", "1", "26.0", "26.0", "", "", "89.1", "83.2", "", "45.2", "", "2", "", "", "203", "1", "1", "", "", "1", "2", "0", "44.02", "0", "25", "1", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "92.7", "96.9", "", "", "", "", "96.1"]} -{"pcdb_id": 18282, "brand_name": "Firebird", "model_name": "Enviromax Combi HE", "model_qualifier": "35kW", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 82.7, "comparative_hot_water_efficiency_pct": 45.0, "output_kw_max": 35.0, "final_year_of_manufacture": null, "raw": ["018282", "000047", "0", "2024/Jan/31 10:17", "Firebird Heating Solutions Ltd", "Firebird", "Enviromax Combi HE", "35kW", "", "2017", "current", "4", "1", "1", "2", "0", "", "", "2", "2", "1", "35.0", "35.0", "", "", "88.7", "82.7", "", "45.0", "", "2", "", "", "203", "1", "1", "", "", "1", "2", "0", "44.02", "0", "25", "1", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "92.5", "95.9", "", "", "", "", "95.2"]} -{"pcdb_id": 18283, "brand_name": "Biasi", "model_name": "ADVANCE 25C", "model_qualifier": "", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 55.8, "output_kw_max": 20.3, "final_year_of_manufacture": null, "raw": ["018283", "000208", "0", "2018/Jan/15 11:13", "Biasi", "Biasi", "ADVANCE 25C", "", "47-583-43", "2017", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "20.3", "20.3", "", "", "87.9", "79.3", "", "55.8", "", "2", "", "", "104", "1", "2", "36", "3", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.0", "96.9", "", "", "", "", "95.1"]} -{"pcdb_id": 18284, "brand_name": "Biasi", "model_name": "ADVANCE 30C", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 55.8, "output_kw_max": 24.4, "final_year_of_manufacture": null, "raw": ["018284", "000208", "0", "2018/Jan/15 11:14", "Biasi", "Biasi", "ADVANCE 30C", "", "47-583-44", "2017", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.4", "24.4", "", "", "88.0", "79.4", "", "55.8", "", "2", "", "", "104", "1", "2", "40", "3", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "96.8", "", "", "", "", "95.1"]} -{"pcdb_id": 18285, "brand_name": "Biasi", "model_name": "ADVANCE 35C", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 55.8, "output_kw_max": 28.2, "final_year_of_manufacture": null, "raw": ["018285", "000208", "0", "2018/Jan/15 11:14", "Biasi", "Biasi", "ADVANCE 35C", "", "47-583-45", "2017", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28.2", "28.2", "", "", "88.0", "79.4", "", "55.8", "", "2", "", "", "104", "1", "2", "53", "3", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "96.8", "", "", "", "", "95.1"]} -{"pcdb_id": 18286, "brand_name": "Biasi", "model_name": "ADVANCE 25S", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 24.4, "final_year_of_manufacture": null, "raw": ["018286", "000208", "0", "2018/Jan/15 11:15", "Biasi", "Biasi", "ADVANCE 25S", "", "41-583-33", "2017", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24.4", "24.4", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "40", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "96.8", "", "", "", "", "95.1"]} -{"pcdb_id": 18287, "brand_name": "Biasi", "model_name": "ADVANCE 30S", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 28.2, "final_year_of_manufacture": null, "raw": ["018287", "000208", "0", "2018/Jan/15 11:15", "Biasi", "Biasi", "ADVANCE 30S", "", "41-583-34", "2017", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "28.2", "28.2", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "53", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "96.8", "", "", "", "", "95.1"]} -{"pcdb_id": 18288, "brand_name": "Keston", "model_name": "COMBI C35P", "model_qualifier": "", "winter_efficiency_pct": 90.1, "summer_efficiency_pct": 81.5, "comparative_hot_water_efficiency_pct": 57.3, "output_kw_max": 24.2, "final_year_of_manufacture": null, "raw": ["018288", "000022", "0", "2018/Jan/15 10:42", "Keston Boilers", "Keston", "COMBI C35P", "", "", "2017", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "90.1", "81.5", "", "57.3", "", "2", "1", "", "104", "1", "2", "29", "5", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "92.0", "100.8", "", "", "", "", "99.1"]} -{"pcdb_id": 18289, "brand_name": "De Dietrich", "model_name": "MPX", "model_qualifier": "24 COMPACT", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 24.0, "final_year_of_manufacture": null, "raw": ["018289", "000305", "0", "2018/Jan/17 15:42", "De Dietrich Thermique", "De Dietrich", "MPX", "24 COMPACT", "", "2018", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24.0", "24.0", "", "", "88.5", "79.5", "", "58.1", "", "2", "", "", "102", "1", "2", "42", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "98.0", "", "", "", "", "96.1"]} -{"pcdb_id": 18290, "brand_name": "De Dietrich", "model_name": "MPX", "model_qualifier": "24 COMPACT", "winter_efficiency_pct": 89.5, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 58.8, "output_kw_max": 24.0, "final_year_of_manufacture": null, "raw": ["018290", "000305", "0", "2018/Jan/17 15:42", "De Dietrich Thermique", "De Dietrich", "MPX", "24 COMPACT", "", "2018", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "24.0", "24.0", "", "", "89.5", "80.5", "", "58.8", "", "2", "1", "", "102", "1", "2", "42", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.9", "100.2", "", "", "", "", "98.2"]} -{"pcdb_id": 18291, "brand_name": "De Dietrich", "model_name": "MPX", "model_qualifier": "20/24 MI COMPACT", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 56.2, "output_kw_max": 24.0, "final_year_of_manufacture": null, "raw": ["018291", "000305", "0", "2018/Jan/17 15:42", "De Dietrich Thermique", "De Dietrich", "MPX", "20/24 MI COMPACT", "", "2018", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.0", "24.0", "", "", "88.5", "79.9", "", "56.2", "", "2", "", "", "104", "1", "2", "30", "3", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "98.0", "", "", "", "", "96.1"]} -{"pcdb_id": 18292, "brand_name": "De Dietrich", "model_name": "MPX", "model_qualifier": "20/24 MI COMPACT", "winter_efficiency_pct": 89.5, "summer_efficiency_pct": 80.9, "comparative_hot_water_efficiency_pct": 56.9, "output_kw_max": 24.0, "final_year_of_manufacture": null, "raw": ["018292", "000305", "0", "2018/Jan/17 15:42", "De Dietrich Thermique", "De Dietrich", "MPX", "20/24 MI COMPACT", "", "2018", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24.0", "24.0", "", "", "89.5", "80.9", "", "56.9", "", "2", "1", "", "104", "1", "2", "30", "3", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.0", "100.2", "", "", "", "", "98.3"]} -{"pcdb_id": 18293, "brand_name": "De Dietrich", "model_name": "MPX", "model_qualifier": "24/28 MI COMPACT", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 56.2, "output_kw_max": 28.0, "final_year_of_manufacture": null, "raw": ["018293", "000305", "0", "2018/Jan/17 15:43", "De Dietrich Thermique", "De Dietrich", "MPX", "24/28 MI COMPACT", "", "2018", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28.0", "28.0", "", "", "88.5", "79.9", "", "56.2", "", "2", "", "", "104", "1", "2", "42", "3", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "98.0", "", "", "", "", "96.1"]} -{"pcdb_id": 18295, "brand_name": "De Dietrich", "model_name": "MPX", "model_qualifier": "24/28 MI COMPACT", "winter_efficiency_pct": 89.5, "summer_efficiency_pct": 80.9, "comparative_hot_water_efficiency_pct": 56.9, "output_kw_max": 28.0, "final_year_of_manufacture": null, "raw": ["018295", "000305", "0", "2018/Jan/17 17:00", "De Dietrich Thermique", "De Dietrich", "MPX", "24/28 MI COMPACT", "", "2018", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "28.0", "28.0", "", "", "89.5", "80.9", "", "56.9", "", "2", "1", "", "104", "1", "2", "42", "3", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.9", "100.2", "", "", "", "", "98.2"]} -{"pcdb_id": 18296, "brand_name": "De Dietrich", "model_name": "MPX", "model_qualifier": "28/33 MI COMPACT", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 56.2, "output_kw_max": 33.0, "final_year_of_manufacture": null, "raw": ["018296", "000305", "0", "2018/Jan/17 15:43", "De Dietrich Thermique", "De Dietrich", "MPX", "28/33 MI COMPACT", "", "2018", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "33.0", "33.0", "", "", "88.5", "79.9", "", "56.2", "", "2", "", "", "104", "1", "2", "41", "3", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.1", "98.1", "", "", "", "", "96.2"]} -{"pcdb_id": 18297, "brand_name": "De Dietrich", "model_name": "MPX", "model_qualifier": "28/33 MI COMPACT", "winter_efficiency_pct": 89.6, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 56.9, "output_kw_max": 33.0, "final_year_of_manufacture": null, "raw": ["018297", "000305", "0", "2018/Jan/17 17:04", "De Dietrich Thermique", "De Dietrich", "MPX", "28/33 MI COMPACT", "", "2018", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "33.0", "33.0", "", "", "89.6", "81.0", "", "56.9", "", "2", "1", "", "104", "1", "2", "41", "3", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.1", "100.3", "", "", "", "", "98.4"]} -{"pcdb_id": 18298, "brand_name": "De Dietrich", "model_name": "MPX", "model_qualifier": "28/33 BIC", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 56.2, "output_kw_max": 33.0, "final_year_of_manufacture": null, "raw": ["018298", "000305", "0", "2018/Jan/17 15:43", "De Dietrich Thermique", "De Dietrich", "MPX", "28/33 BIC", "", "2018", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "33.0", "33.0", "", "", "88.5", "79.9", "", "56.2", "", "2", "", "", "104", "1", "2", "41", "3", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.1", "98.1", "", "", "", "", "96.2"]} -{"pcdb_id": 18299, "brand_name": "De Dietrich", "model_name": "MPX", "model_qualifier": "28/33 BIC", "winter_efficiency_pct": 89.6, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 56.9, "output_kw_max": 33.0, "final_year_of_manufacture": null, "raw": ["018299", "000305", "0", "2018/Jan/17 15:43", "De Dietrich Thermique", "De Dietrich", "MPX", "28/33 BIC", "", "2018", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "33.0", "33.0", "", "", "89.6", "81.0", "", "56.9", "", "2", "1", "", "104", "1", "2", "41", "3", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.1", "100.3", "", "", "", "", "98.4"]} -{"pcdb_id": 18300, "brand_name": "Warmhaus", "model_name": "Enerwa", "model_qualifier": "Plus 2530 C", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 56.1, "output_kw_max": 23.7, "final_year_of_manufacture": null, "raw": ["018300", "000306", "0", "2018/Apr/09 14:42", "Warmhaus Heating Ltd", "Warmhaus", "Enerwa", "Plus 2530 C", "CE-1015CR0544 16", "2016", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "23.7", "23.7", "", "", "88.4", "79.8", "", "56.1", "", "2", "", "", "104", "1", "2", "70", "5", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "97.6", "", "", "", "", "95.8"]} -{"pcdb_id": 18301, "brand_name": "Warmhaus", "model_name": "Enerwa", "model_qualifier": "Plus 3035 C", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 55.9, "output_kw_max": 28.0, "final_year_of_manufacture": null, "raw": ["018301", "000306", "0", "2018/Apr/09 14:42", "Warmhaus Heating Ltd", "Warmhaus", "Enerwa", "Plus 3035 C", "CE-1015CR0553 17", "2016", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28.0", "28.0", "", "", "88.1", "79.5", "", "55.9", "", "2", "", "", "104", "1", "2", "70", "5", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.2", "96.9", "", "", "", "", "95.2"]} -{"pcdb_id": 18302, "brand_name": "Warmhaus", "model_name": "Enerwa", "model_qualifier": "3540 C", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 55.8, "output_kw_max": 33.02, "final_year_of_manufacture": null, "raw": ["018302", "000306", "0", "2018/Apr/09 14:42", "Warmhaus Heating Ltd", "Warmhaus", "Enerwa", "3540 C", "CE-1015CS0565 17", "2016", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "33.02", "33.02", "", "", "88.0", "79.4", "", "55.8", "", "2", "", "", "104", "1", "2", "70", "5", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "96.6", "", "", "", "", "95.0"]} -{"pcdb_id": 18319, "brand_name": "Vokera BY RIELLO", "model_name": "evolve", "model_qualifier": "36c", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 86.8, "comparative_hot_water_efficiency_pct": 77.2, "output_kw_max": 31.0, "final_year_of_manufacture": null, "raw": ["018319", "000011", "0", "2020/Jan/22 13:18", "Vokera", "Vokera BY RIELLO", "evolve", "36c", "20131016", "2017", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "31", "31", "", "", "88.8", "86.8", "", "77.2", "", "2", "", "", "104", "1", "2", "31", "3", "0", "", "", "", "0", "", "", "", "", "1", "6.826", "0.116", "0.0005", "0.72894", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "88.4", "98.7", "", "", "", "", "96.7"]} -{"pcdb_id": 18320, "brand_name": "Vokera BY RIELLO", "model_name": "evolve", "model_qualifier": "30s", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 31.39, "final_year_of_manufacture": null, "raw": ["018320", "000011", "0", "2019/Aug/15 09:23", "Vokera", "Vokera BY RIELLO", "evolve", "30s", "20131081", "2017", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "31.39", "31.39", "", "", "88.8", "79.8", "", "58.3", "", "2", "", "", "102", "1", "2", "31", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "88.4", "98.7", "", "", "", "", "96.7"]} -{"pcdb_id": 18322, "brand_name": "ATAG", "model_name": "IC Economiser Plus 35", "model_qualifier": "", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 97.8, "comparative_hot_water_efficiency_pct": 79.9, "output_kw_max": 28.3, "final_year_of_manufacture": null, "raw": ["018322", "000299", "3", "2021/Nov/29 20:19", "ATAG Verwarming Nederland BV", "ATAG", "IC Economiser Plus 35", "", "", "2018", "current", "1", "2", "1", "2", "1", "313", "060043", "2", "3", "2", "28.3", "28.3", "", "", "89.1", "97.8", "", "79.9", "", "2", "", "", "104", "1", "2", "74", "4", "0", "", "", "", "0", "", "", "", "", "2", "6.59", "0.168", "0.0013", "0.50098", "11.94", "0.183", "0.0007", "1.1609", "0.00001", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.6", "99.5", "", "", "", "", "97.4"]} -{"pcdb_id": 18323, "brand_name": "ATAG", "model_name": "IC Economiser Plus 39", "model_qualifier": "", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 97.8, "comparative_hot_water_efficiency_pct": 79.9, "output_kw_max": 28.3, "final_year_of_manufacture": null, "raw": ["018323", "000299", "3", "2021/Nov/29 20:19", "ATAG Verwarming Nederland BV", "ATAG", "IC Economiser Plus 39", "", "", "2018", "current", "1", "2", "1", "2", "1", "313", "060043", "2", "3", "2", "28.3", "28.3", "", "", "89.1", "97.8", "", "79.9", "", "2", "", "", "104", "1", "2", "74", "4", "0", "", "", "", "0", "", "", "", "", "2", "6.59", "0.168", "0.0013", "0.50098", "11.94", "0.183", "0.0007", "1.1609", "0.00001", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.6", "99.5", "", "", "", "", "97.4"]} -{"pcdb_id": 18324, "brand_name": "Vokera BY RIELLO", "model_name": "evolve", "model_qualifier": "42C", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 86.8, "comparative_hot_water_efficiency_pct": 77.0, "output_kw_max": 34.3, "final_year_of_manufacture": null, "raw": ["018324", "000011", "0", "2020/Jan/22 12:59", "Vokera", "Vokera BY RIELLO", "evolve", "42C", "20131017", "2017", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "34.3", "34.3", "", "", "88.7", "86.8", "", "77.0", "", "2", "", "", "104", "1", "2", "34", "3", "0", "", "", "", "0", "", "", "", "", "1", "6.839", "0.121", "0.002", "0.73046", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "", "", "", "", "88.3", "98.6", "", "", "", "", "96.6"]} -{"pcdb_id": 18325, "brand_name": "Trianco", "model_name": "TRO EVOLUTION 20 KITCHEN SYSTEM", "model_qualifier": "", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 81.4, "comparative_hot_water_efficiency_pct": 59.4, "output_kw_max": 20.0, "final_year_of_manufacture": null, "raw": ["018325", "000062", "0", "2020/Jan/22 12:59", "TR Engineering Ltd", "Trianco", "TRO EVOLUTION 20 KITCHEN SYSTEM", "", "", "2018", "current", "4", "1", "1", "1", "0", "", "", "2", "2", "2", "20", "20", "", "", "89.2", "81.4", "", "59.4", "", "2", "", "", "201", "1", "1", "217", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.7", "97.4", "", "", "", "", "96.3"]} -{"pcdb_id": 18326, "brand_name": "Trianco", "model_name": "TRO EVOLUTION 30 KITCHEN SYSTEM", "model_qualifier": "", "winter_efficiency_pct": 89.3, "summer_efficiency_pct": 81.5, "comparative_hot_water_efficiency_pct": 59.5, "output_kw_max": 30.0, "final_year_of_manufacture": null, "raw": ["018326", "000062", "0", "2018/Mar/26 09:30", "TR Engineering Ltd", "Trianco", "TRO EVOLUTION 30 KITCHEN SYSTEM", "", "", "2018", "current", "4", "1", "1", "1", "0", "", "", "2", "2", "2", "30", "30", "", "", "89.3", "81.5", "", "59.5", "", "2", "", "", "201", "1", "1", "217", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.5", "97.8", "", "", "", "", "96.6"]} -{"pcdb_id": 18327, "brand_name": "Vokera BY RIELLO", "model_name": "evolve", "model_qualifier": "35s", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 34.3, "final_year_of_manufacture": null, "raw": ["018327", "000011", "0", "2019/Nov/22 09:56", "Vokera", "Vokera BY RIELLO", "evolve", "35s", "20131082", "2017", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "34.3", "34.3", "", "", "88.7", "79.7", "", "58.3", "", "2", "", "", "102", "1", "2", "34", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "", "", "", "", "88.3", "98.6", "", "", "", "", "96.6"]} -{"pcdb_id": 18329, "brand_name": "Ideal", "model_name": "LOGIC COMBI", "model_qualifier": "C24IE", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 69.8, "output_kw_max": 24.2, "final_year_of_manufacture": null, "raw": ["018329", "000008", "0", "2020/Jan/22 13:00", "Ideal Boilers", "Ideal", "LOGIC COMBI", "C24IE", "47-349-44", "2018", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "89.0", "87.3", "", "69.8", "", "2", "", "", "104", "1", "2", "70", "5", "0", "", "", "", "0", "", "", "", "", "1", "7.549", "0.076", "0.0025", "1.4583", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.0", "98.6", "", "", "", "", "96.9"]} -{"pcdb_id": 18330, "brand_name": "Ideal", "model_name": "LOGIC COMBI", "model_qualifier": "C30IE", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 70.4, "output_kw_max": 24.2, "final_year_of_manufacture": null, "raw": ["018330", "000008", "0", "2020/Jan/22 13:00", "Ideal Boilers", "Ideal", "LOGIC COMBI", "C30IE", "47-349-45", "2018", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "89.0", "87.3", "", "70.4", "", "2", "", "", "104", "1", "2", "70", "5", "0", "", "", "", "0", "", "", "", "", "1", "7.476", "0.74", "0.0025", "1.38753", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.0", "98.6", "", "", "", "", "96.9"]} -{"pcdb_id": 18331, "brand_name": "Ideal", "model_name": "LOGIC COMBI", "model_qualifier": "C35IE", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 71.1, "output_kw_max": 24.2, "final_year_of_manufacture": null, "raw": ["018331", "000008", "0", "2020/Jan/22 13:00", "Ideal Boilers", "Ideal", "LOGIC COMBI", "C35IE", "47-349-46", "2018", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "89.0", "87.3", "", "71.1", "", "2", "", "", "104", "1", "2", "70", "5", "0", "", "", "", "0", "", "", "", "", "1", "7.411", "0.074", "0.0025", "1.3247", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.0", "98.6", "", "", "", "", "96.9"]} -{"pcdb_id": 18335, "brand_name": "Vaillant", "model_name": "ecoTEC plus", "model_qualifier": "VU 446/5-5 (H-GB)", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 45.2, "final_year_of_manufacture": null, "raw": ["018335", "000031", "0", "2020/Jan/22 13:00", "Vaillant", "Vaillant", "ecoTEC plus", "VU 446/5-5 (H-GB)", "41-649-28", "2018", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "45.2", "45.2", "", "", "88.6", "79.6", "", "58.1", "", "2", "", "", "102", "1", "2", "24", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0045", "", "", "", "", "", "", "", "", "87.8", "98.3", "", "", "", "", "96.3"]} -{"pcdb_id": 18336, "brand_name": "Vaillant", "model_name": "ecoTEC plus", "model_qualifier": "VU 446/5-5 (H-GB)", "winter_efficiency_pct": 89.3, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 58.7, "output_kw_max": 45.2, "final_year_of_manufacture": null, "raw": ["018336", "000031", "0", "2019/Jul/31 11:50", "Vaillant", "Vaillant", "ecoTEC plus", "VU 446/5-5 (H-GB)", "41-649-28", "2018", "current", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "45.2", "45.2", "", "", "89.3", "80.3", "", "58.7", "", "2", "0", "", "102", "1", "2", "24", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0045", "", "", "", "", "", "", "", "", "89.7", "97.3", "", "", "", "", "95.8"]} -{"pcdb_id": 18337, "brand_name": "Vaillant", "model_name": "ecoTEC plus", "model_qualifier": "VU 606/5-5 (H-GB)", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 60.0, "final_year_of_manufacture": null, "raw": ["018337", "000031", "0", "2019/Jul/31 11:51", "Vaillant", "Vaillant", "ecoTEC plus", "VU 606/5-5 (H-GB)", "41-649-29", "2018", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "60", "60", "", "", "88.8", "79.8", "", "58.3", "", "2", "", "", "102", "1", "2", "31", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0045", "", "", "", "", "", "", "", "", "88.1", "98.7", "", "", "", "", "96.7"]} -{"pcdb_id": 18338, "brand_name": "Vaillant", "model_name": "ecoTEC plus", "model_qualifier": "VU 606/5-5 (H-GB)", "winter_efficiency_pct": 89.7, "summer_efficiency_pct": 80.7, "comparative_hot_water_efficiency_pct": 59.0, "output_kw_max": 60.0, "final_year_of_manufacture": null, "raw": ["018338", "000031", "0", "2019/Jul/31 11:51", "Vaillant", "Vaillant", "ecoTEC plus", "VU 606/5-5 (H-GB)", "41-649-29", "2018", "current", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "60", "60", "", "", "89.7", "80.7", "", "59.0", "", "2", "0", "", "102", "1", "2", "31", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0045", "", "", "", "", "", "", "", "", "89.7", "98.3", "", "", "", "", "96.6"]} -{"pcdb_id": 18339, "brand_name": "Ideal", "model_name": "LOGIC COMBI C IE", "model_qualifier": "C24P IE", "winter_efficiency_pct": 90.1, "summer_efficiency_pct": 81.5, "comparative_hot_water_efficiency_pct": 57.3, "output_kw_max": 24.2, "final_year_of_manufacture": null, "raw": ["018339", "000008", "0", "2018/May/16 14:16", "Ideal Boilers", "Ideal", "LOGIC COMBI C IE", "C24P IE", "", "2018", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "90.1", "81.5", "", "57.3", "", "2", "1", "", "104", "1", "2", "42", "5", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "92.0", "100.8", "", "", "", "", "99.1"]} -{"pcdb_id": 18340, "brand_name": "Ideal", "model_name": "LOGIC COMBI C IE", "model_qualifier": "C30P IE", "winter_efficiency_pct": 90.1, "summer_efficiency_pct": 81.5, "comparative_hot_water_efficiency_pct": 57.3, "output_kw_max": 24.2, "final_year_of_manufacture": null, "raw": ["018340", "000008", "0", "2018/May/16 14:16", "Ideal Boilers", "Ideal", "LOGIC COMBI C IE", "C30P IE", "", "2018", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "90.1", "81.5", "", "57.3", "", "2", "1", "", "104", "1", "2", "31", "5", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "92.0", "100.8", "", "", "", "", "99.1"]} -{"pcdb_id": 18341, "brand_name": "Ideal", "model_name": "LOGIC HEAT", "model_qualifier": "H12IE", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 12.0, "final_year_of_manufacture": null, "raw": ["018341", "000008", "0", "2018/Apr/19 12:49", "Ideal Boilers", "Ideal", "LOGIC HEAT", "H12IE", "41-750-92", "2018", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "12", "12", "", "", "88.8", "79.8", "", "58.3", "", "2", "", "", "102", "1", "2", "20", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.0", "97.9", "", "", "", "", "96.4"]} -{"pcdb_id": 18342, "brand_name": "Ideal", "model_name": "LOGIC HEAT", "model_qualifier": "H15IE", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 15.0, "final_year_of_manufacture": null, "raw": ["018342", "000008", "0", "2018/Apr/19 12:50", "Ideal Boilers", "Ideal", "LOGIC HEAT", "H15IE", "41-750-93", "2018", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "15.0", "15.0", "", "", "88.7", "79.7", "", "58.2", "", "2", "", "", "102", "1", "2", "21", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.0", "97.8", "", "", "", "", "96.4"]} -{"pcdb_id": 18343, "brand_name": "Ideal", "model_name": "LOGIC HEAT", "model_qualifier": "H18IE", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 18.0, "final_year_of_manufacture": null, "raw": ["018343", "000008", "0", "2018/Apr/19 12:51", "Ideal Boilers", "Ideal", "LOGIC HEAT", "H18IE", "41-750-94", "2018", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18.0", "18.0", "", "", "89.0", "80.0", "", "58.4", "", "2", "", "", "102", "1", "2", "26", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.8", "98.5", "", "", "", "", "96.8"]} -{"pcdb_id": 18344, "brand_name": "Ideal", "model_name": "LOGIC HEAT", "model_qualifier": "H24IE", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 24.2, "final_year_of_manufacture": null, "raw": ["018344", "000008", "0", "2018/Apr/19 12:51", "Ideal Boilers", "Ideal", "LOGIC HEAT", "H24IE", "41-750-95", "2018", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "89.0", "80.0", "", "58.5", "", "2", "", "", "102", "1", "2", "42", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.0", "98.6", "", "", "", "", "96.9"]} -{"pcdb_id": 18345, "brand_name": "Ideal", "model_name": "LOGIC HEAT", "model_qualifier": "H30IE", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 30.3, "final_year_of_manufacture": null, "raw": ["018345", "000008", "0", "2018/Apr/19 12:52", "Ideal Boilers", "Ideal", "LOGIC HEAT", "H30IE", "41-750-96", "2018", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "30.3", "30.3", "", "", "88.8", "79.8", "", "58.3", "", "2", "", "", "102", "1", "2", "48", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.6", "98.2", "", "", "", "", "96.6"]} -{"pcdb_id": 18346, "brand_name": "Ideal", "model_name": "LOGIC HEAT HIE", "model_qualifier": "H24P IE", "winter_efficiency_pct": 90.1, "summer_efficiency_pct": 81.1, "comparative_hot_water_efficiency_pct": 59.2, "output_kw_max": 24.2, "final_year_of_manufacture": null, "raw": ["018346", "000008", "0", "2018/May/16 14:17", "Ideal Boilers", "Ideal", "LOGIC HEAT HIE", "H24P IE", "", "2018", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "90.1", "81.1", "", "59.2", "", "2", "1", "", "102", "1", "2", "42", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "92.0", "100.8", "", "", "", "", "99.1"]} -{"pcdb_id": 18347, "brand_name": "Ideal", "model_name": "LOGIC HEAT HIE", "model_qualifier": "H30P IE", "winter_efficiency_pct": 89.8, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 59.1, "output_kw_max": 30.3, "final_year_of_manufacture": null, "raw": ["018347", "000008", "0", "2018/May/16 14:17", "Ideal Boilers", "Ideal", "LOGIC HEAT HIE", "H30P IE", "", "2018", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "30.3", "30.3", "", "", "89.8", "80.8", "", "59.1", "", "2", "1", "", "102", "1", "2", "31", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "91.6", "100.4", "", "", "", "", "98.7"]} -{"pcdb_id": 18348, "brand_name": "Ideal", "model_name": "VOGUE", "model_qualifier": "C26IE GEN2", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 76.2, "output_kw_max": 18.0, "final_year_of_manufacture": null, "raw": ["018348", "000008", "0", "2020/Jan/22 13:00", "Ideal Boilers", "Ideal", "VOGUE", "C26IE GEN2", "47-349-47", "2018", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "18.0", "18.0", "", "", "88.6", "87.3", "", "76.2", "", "2", "", "", "104", "1", "2", "47", "3", "0", "", "", "", "0", "", "", "", "", "1", "6.915", "0.085", "0.0011", "0.8454", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.7", "97.7", "", "", "", "", "96.2"]} -{"pcdb_id": 18349, "brand_name": "Ideal", "model_name": "VOGUE", "model_qualifier": "C32IE GEN2", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 77.7, "output_kw_max": 26.0, "final_year_of_manufacture": null, "raw": ["018349", "000008", "0", "2020/Jan/22 13:00", "Ideal Boilers", "Ideal", "VOGUE", "C32IE GEN2", "47-349-48", "2018", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "26.0", "26.0", "", "", "88.7", "87.3", "", "77.7", "", "2", "", "", "104", "1", "2", "63", "3", "0", "", "", "", "0", "", "", "", "", "1", "6.78", "0.086", "0.001", "0.71939", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.9", "97.8", "", "", "", "", "96.3"]} -{"pcdb_id": 18350, "brand_name": "Ideal", "model_name": "VOGUE", "model_qualifier": "C40IE GEN2", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 77.2, "output_kw_max": 32.0, "final_year_of_manufacture": null, "raw": ["018350", "000008", "0", "2020/Jan/22 13:01", "Ideal Boilers", "Ideal", "VOGUE", "C40IE GEN2", "47-349-49", "2018", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "32.0", "32.0", "", "", "88.6", "87.3", "", "77.2", "", "2", "", "", "104", "1", "2", "44", "3", "0", "", "", "", "0", "", "", "", "", "1", "6.821", "0.086", "0.001", "0.75466", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.7", "97.5", "", "", "", "", "96.0"]} -{"pcdb_id": 18351, "brand_name": "Ideal", "model_name": "VOGUE", "model_qualifier": "C26P IE GEN2", "winter_efficiency_pct": 89.6, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 57.0, "output_kw_max": 18.0, "final_year_of_manufacture": null, "raw": ["018351", "000008", "0", "2018/Apr/19 12:55", "Ideal Boilers", "Ideal", "VOGUE", "C26P IE GEN2", "", "2018", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "18.0", "18.0", "", "", "89.6", "81.0", "", "57.0", "", "2", "1", "", "104", "1", "2", "47", "3", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "91.7", "99.8", "", "", "", "", "98.3"]} -{"pcdb_id": 18352, "brand_name": "Ideal", "model_name": "VOGUE", "model_qualifier": "C32P IE GEN2", "winter_efficiency_pct": 89.7, "summer_efficiency_pct": 81.1, "comparative_hot_water_efficiency_pct": 57.1, "output_kw_max": 26.0, "final_year_of_manufacture": null, "raw": ["018352", "000008", "0", "2018/Apr/19 12:56", "Ideal Boilers", "Ideal", "VOGUE", "C32P IE GEN2", "", "2018", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "26.0", "26.0", "", "", "89.7", "81.1", "", "57.1", "", "2", "1", "", "104", "1", "2", "63", "3", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "91.9", "100.0", "", "", "", "", "98.5"]} -{"pcdb_id": 18353, "brand_name": "Ideal", "model_name": "VOGUE", "model_qualifier": "C40P IE GEN2", "winter_efficiency_pct": 89.6, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 56.9, "output_kw_max": 32.0, "final_year_of_manufacture": null, "raw": ["018353", "000008", "0", "2018/Apr/19 12:56", "Ideal Boilers", "Ideal", "VOGUE", "C40P IE GEN2", "", "2018", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "32.0", "32.0", "", "", "89.6", "81.0", "", "56.9", "", "2", "1", "", "104", "1", "2", "44", "3", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "91.7", "99.7", "", "", "", "", "98.1"]} -{"pcdb_id": 18354, "brand_name": "Ideal", "model_name": "VOGUE", "model_qualifier": "S15IE GEN2", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 15.0, "final_year_of_manufacture": null, "raw": ["018354", "000008", "0", "2018/Apr/19 12:56", "Ideal Boilers", "Ideal", "VOGUE", "S15IE GEN2", "41-750-97", "2018", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "15.0", "15.0", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "25", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.6", "97.0", "", "", "", "", "95.6"]} -{"pcdb_id": 18355, "brand_name": "Ideal", "model_name": "VOGUE", "model_qualifier": "S18IE GEN2", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 18.0, "final_year_of_manufacture": null, "raw": ["018355", "000008", "0", "2018/Apr/19 12:56", "Ideal Boilers", "Ideal", "VOGUE", "S18IE GEN2", "41-750-98", "2018", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18.0", "18.0", "", "", "88.7", "79.7", "", "58.2", "", "2", "", "", "102", "1", "2", "40", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.8", "97.8", "", "", "", "", "96.3"]} -{"pcdb_id": 18356, "brand_name": "Ideal", "model_name": "VOGUE", "model_qualifier": "S26IE GEN2", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 26.0, "final_year_of_manufacture": null, "raw": ["018356", "000008", "0", "2018/Apr/19 12:57", "Ideal Boilers", "Ideal", "VOGUE", "S26IE GEN2", "41-750-99", "2018", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "26.0", "26.0", "", "", "88.7", "79.7", "", "58.2", "", "2", "", "", "102", "1", "2", "45", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.7", "97.8", "", "", "", "", "96.2"]} -{"pcdb_id": 18357, "brand_name": "Ideal", "model_name": "VOGUE", "model_qualifier": "S32IE GEN2", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 32.0, "final_year_of_manufacture": null, "raw": ["018357", "000008", "0", "2018/Apr/19 12:57", "Ideal Boilers", "Ideal", "VOGUE", "S32IE GEN2", "41-796-01", "2018", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "32.0", "32.0", "", "", "88.7", "79.7", "", "58.2", "", "2", "", "", "102", "1", "2", "49", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.8", "97.8", "", "", "", "", "96.3"]} -{"pcdb_id": 18358, "brand_name": "Ideal", "model_name": "VOGUE", "model_qualifier": "S15P IE GEN2", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 80.4, "comparative_hot_water_efficiency_pct": 58.7, "output_kw_max": 15.0, "final_year_of_manufacture": null, "raw": ["018358", "000008", "0", "2018/Apr/19 12:57", "Ideal Boilers", "Ideal", "VOGUE", "S15P IE GEN2", "", "2018", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "15.0", "15.0", "", "", "89.4", "80.4", "", "58.7", "", "2", "1", "", "102", "1", "2", "25", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "91.5", "99.2", "", "", "", "", "97.7"]} -{"pcdb_id": 18359, "brand_name": "Ideal", "model_name": "VOGUE", "model_qualifier": "S18P IE GEN2", "winter_efficiency_pct": 89.7, "summer_efficiency_pct": 80.7, "comparative_hot_water_efficiency_pct": 59.0, "output_kw_max": 18.0, "final_year_of_manufacture": null, "raw": ["018359", "000008", "0", "2018/Apr/19 12:58", "Ideal Boilers", "Ideal", "VOGUE", "S18P IE GEN2", "", "2018", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "18.0", "18.0", "", "", "89.7", "80.7", "", "59.0", "", "2", "1", "", "102", "1", "2", "40", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "91.8", "100.0", "", "", "", "", "98.5"]} -{"pcdb_id": 18360, "brand_name": "Ideal", "model_name": "VOGUE", "model_qualifier": "S26P IE GEN2", "winter_efficiency_pct": 89.7, "summer_efficiency_pct": 80.7, "comparative_hot_water_efficiency_pct": 58.9, "output_kw_max": 26.0, "final_year_of_manufacture": null, "raw": ["018360", "000008", "0", "2018/Apr/19 12:58", "Ideal Boilers", "Ideal", "VOGUE", "S26P IE GEN2", "", "2018", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "26.0", "26.0", "", "", "89.7", "80.7", "", "58.9", "", "2", "1", "", "102", "1", "2", "45", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "91.7", "99.9", "", "", "", "", "98.4"]} -{"pcdb_id": 18361, "brand_name": "Ideal", "model_name": "VOGUE", "model_qualifier": "S32P IE GEN2", "winter_efficiency_pct": 89.7, "summer_efficiency_pct": 80.7, "comparative_hot_water_efficiency_pct": 59.0, "output_kw_max": 32.0, "final_year_of_manufacture": null, "raw": ["018361", "000008", "0", "2018/Apr/19 12:58", "Ideal Boilers", "Ideal", "VOGUE", "S32P IE GEN2", "", "2018", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "32.0", "32.0", "", "", "89.7", "80.7", "", "59.0", "", "2", "1", "", "102", "1", "2", "49", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "91.8", "100.0", "", "", "", "", "98.5"]} -{"pcdb_id": 18368, "brand_name": "Vokera BY RIELLO", "model_name": "evolve", "model_qualifier": "28C", "winter_efficiency_pct": 89.9, "summer_efficiency_pct": 81.3, "comparative_hot_water_efficiency_pct": 57.2, "output_kw_max": 24.0, "final_year_of_manufacture": null, "raw": ["018368", "000011", "0", "2021/Feb/22 13:09", "Vokera", "Vokera BY RIELLO", "evolve", "28C", "40 364 57", "2017", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24.0", "24.0", "", "", "89.9", "81.3", "", "57.2", "", "2", "0", "", "104", "1", "2", "37", "3", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.4", "98.8", "", "", "", "", "97.0"]} -{"pcdb_id": 18372, "brand_name": "Ideal", "model_name": "Classic", "model_qualifier": "35", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 69.0, "output_kw_max": 24.2, "final_year_of_manufacture": null, "raw": ["018372", "000008", "0", "2020/Jan/22 13:01", "Ideal Boilers", "Ideal", "Classic", "35", "86CM68", "2018", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "88.4", "87.3", "", "69.0", "", "2", "", "", "104", "1", "2", "29", "5", "0", "", "", "0", "0", "", "", "", "", "1", "7.627", "0.074", "0.0023", "1.53009", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.8", "96.9", "", "", "", "", "95.6"]} -{"pcdb_id": 18373, "brand_name": "Daikin", "model_name": "D2CND024A4AA", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 56.1, "output_kw_max": 23.5, "final_year_of_manufacture": null, "raw": ["018373", "000278", "0", "2018/Sep/25 15:39", "Daikin Europe NV", "Daikin", "D2CND024A4AA", "", "47-464-08", "2017", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "23.5", "23.5", "", "", "88.3", "79.7", "", "56.1", "", "2", "", "", "104", "1", "2", "27", "3", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.3", "97.9", "", "", "", "", "95.9"]} -{"pcdb_id": 18374, "brand_name": "Daikin", "model_name": "D2CND024A4AA", "model_qualifier": "D2CND024A4AAS", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 23.5, "final_year_of_manufacture": null, "raw": ["018374", "000278", "0", "2018/Sep/25 15:40", "Daikin Europe NV", "Daikin", "D2CND024A4AA", "D2CND024A4AAS", "47-464-08", "2017", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "23.5", "23.5", "", "", "88.3", "79.3", "", "58.0", "", "2", "", "", "102", "1", "2", "27", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.3", "97.9", "", "", "", "", "95.9"]} -{"pcdb_id": 18375, "brand_name": "Daikin", "model_name": "D2CND028A4AA", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 56.2, "output_kw_max": 27.0, "final_year_of_manufacture": null, "raw": ["018375", "000278", "0", "2018/Sep/24 13:01", "Daikin Europe NV", "Daikin", "D2CND028A4AA", "", "47-464-10", "2017", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "27.0", "27.0", "", "", "88.5", "79.9", "", "56.2", "", "2", "", "", "104", "1", "2", "37", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "98.1", "", "", "", "", "96.2"]} -{"pcdb_id": 18376, "brand_name": "Daikin", "model_name": "D2CND028A4AA", "model_qualifier": "D2CND028A4AAS", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 27.0, "final_year_of_manufacture": null, "raw": ["018376", "000278", "0", "2018/Sep/24 15:59", "Daikin Europe NV", "Daikin", "D2CND028A4AA", "D2CND028A4AAS", "47-464-10", "2017", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "27.0", "27.0", "", "", "88.5", "79.5", "", "58.1", "", "2", "", "", "102", "1", "2", "37", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "98.1", "", "", "", "", "96.2"]} -{"pcdb_id": 18377, "brand_name": "Daikin", "model_name": "D2CND035A4AA", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 56.1, "output_kw_max": 34.0, "final_year_of_manufacture": null, "raw": ["018377", "000278", "0", "2018/Sep/24 13:01", "Daikin Europe NV", "Daikin", "D2CND035A4AA", "", "47-464-09", "2017", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "34.0", "34.0", "", "", "88.4", "79.8", "", "56.1", "", "2", "", "", "104", "1", "2", "37", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "97.9", "", "", "", "", "96.0"]} -{"pcdb_id": 18378, "brand_name": "Daikin", "model_name": "D2CND035A4AA", "model_qualifier": "D2CND035A4AAS", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 34.0, "final_year_of_manufacture": null, "raw": ["018378", "000278", "0", "2018/Sep/24 16:00", "Daikin Europe NV", "Daikin", "D2CND035A4AA", "D2CND035A4AAS", "47-464-09", "2017", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "34.0", "34.0", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "37", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "97.9", "", "", "", "", "96.0"]} -{"pcdb_id": 18379, "brand_name": "Daikin", "model_name": "D2TND012A4AA", "model_qualifier": "", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 11.0, "final_year_of_manufacture": null, "raw": ["018379", "000278", "0", "2019/Jan/14 15:06", "Daikin Europe NV", "Daikin", "D2TND012A4AA", "", "41-464-03", "2017", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "11.0", "11.0", "", "", "88.7", "79.7", "", "58.2", "", "2", "", "", "102", "1", "2", "12", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "98.7", "", "", "", "", "96.6"]} -{"pcdb_id": 18380, "brand_name": "Daikin", "model_name": "D2TND018A4AA", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 17.4, "final_year_of_manufacture": null, "raw": ["018380", "000278", "0", "2019/Jan/14 15:06", "Daikin Europe NV", "Daikin", "D2TND018A4AA", "", "41-464-02", "2017", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "17.4", "17.4", "", "", "88.5", "79.5", "", "58.1", "", "2", "", "", "102", "1", "2", "19", "4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.5", "98.3", "", "", "", "", "96.2"]} -{"pcdb_id": 18381, "brand_name": "Daikin", "model_name": "D2TND024A4AA", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 23.5, "final_year_of_manufacture": null, "raw": ["018381", "000278", "0", "2018/Sep/25 15:40", "Daikin Europe NV", "Daikin", "D2TND024A4AA", "", "41-464-01", "2017", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "23.5", "23.5", "", "", "88.3", "79.3", "", "58.0", "", "2", "", "", "102", "1", "2", "27", "4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.3", "97.9", "", "", "", "", "95.9"]} -{"pcdb_id": 18382, "brand_name": "Daikin", "model_name": "D2TND028A4AA", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 27.0, "final_year_of_manufacture": null, "raw": ["018382", "000278", "0", "2018/Sep/25 15:40", "Daikin Europe NV", "Daikin", "D2TND028A4AA", "", "41-464-05", "2017", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "27.0", "27.0", "", "", "88.5", "79.5", "", "58.1", "", "2", "", "", "102", "1", "2", "35.6", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "98.1", "", "", "", "", "96.2"]} -{"pcdb_id": 18383, "brand_name": "Daikin", "model_name": "D2TND035A4AA", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 34.0, "final_year_of_manufacture": null, "raw": ["018383", "000278", "0", "2018/Sep/25 15:39", "Daikin Europe NV", "Daikin", "D2TND035A4AA", "", "41-464-04", "2017", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "34.0", "34.0", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "54", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "97.9", "", "", "", "", "96.0"]} -{"pcdb_id": 18384, "brand_name": "Cosmogas", "model_name": "MYDENS", "model_qualifier": "24B", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 25.5, "final_year_of_manufacture": null, "raw": ["018384", "000309", "0", "2018/Apr/25 09:31", "Cosmogas srl", "Cosmogas", "MYDENS", "24B", "", "2013", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "25.5", "25.5", "", "", "88.3", "79.3", "", "57.9", "", "2", "", "", "102", "1", "2", "12", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.5", "97.8", "", "", "", "", "95.8"]} -{"pcdb_id": 18385, "brand_name": "Cosmogas", "model_name": "MYDENS", "model_qualifier": "24C", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 25.5, "final_year_of_manufacture": null, "raw": ["018385", "000309", "0", "2018/Apr/25 09:30", "Cosmogas srl", "Cosmogas", "MYDENS", "24C", "", "2013", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "25.5", "25.5", "", "", "88.3", "79.3", "", "57.9", "", "2", "", "", "102", "1", "2", "12", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.5", "97.8", "", "", "", "", "95.8"]} -{"pcdb_id": 18386, "brand_name": "Cosmogas", "model_name": "MYDENS", "model_qualifier": "24P", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 56.0, "output_kw_max": 25.5, "final_year_of_manufacture": null, "raw": ["018386", "000309", "0", "2018/Apr/25 09:30", "Cosmogas srl", "Cosmogas", "MYDENS", "24P", "", "2013", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "25.5", "25.5", "", "", "88.3", "79.7", "", "56.0", "", "2", "", "", "104", "1", "2", "12", "5", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.5", "97.8", "", "", "", "", "95.8"]} -{"pcdb_id": 18387, "brand_name": "Cosmogas", "model_name": "MYDENS", "model_qualifier": "34B", "winter_efficiency_pct": 87.7, "summer_efficiency_pct": 78.7, "comparative_hot_water_efficiency_pct": 57.5, "output_kw_max": 32.0, "final_year_of_manufacture": null, "raw": ["018387", "000309", "0", "2018/Apr/25 09:29", "Cosmogas srl", "Cosmogas", "MYDENS", "34B", "", "2013", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "32.0", "32.0", "", "", "87.7", "78.7", "", "57.5", "", "2", "", "", "102", "1", "2", "12", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.1", "96.4", "", "", "", "", "94.6"]} -{"pcdb_id": 18388, "brand_name": "Cosmogas", "model_name": "MYDENS", "model_qualifier": "34C", "winter_efficiency_pct": 87.7, "summer_efficiency_pct": 78.7, "comparative_hot_water_efficiency_pct": 57.5, "output_kw_max": 32.0, "final_year_of_manufacture": null, "raw": ["018388", "000309", "0", "2018/Apr/25 09:28", "Cosmogas srl", "Cosmogas", "MYDENS", "34C", "", "2013", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "32.0", "32.0", "", "", "87.7", "78.7", "", "57.5", "", "2", "", "", "102", "1", "2", "12", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.1", "96.4", "", "", "", "", "94.6"]} -{"pcdb_id": 18389, "brand_name": "Cosmogas", "model_name": "MYDENS", "model_qualifier": "34P", "winter_efficiency_pct": 87.7, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 55.6, "output_kw_max": 32.0, "final_year_of_manufacture": null, "raw": ["018389", "000309", "0", "2018/Apr/25 09:25", "Cosmogas srl", "Cosmogas", "MYDENS", "34P", "", "2013", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "32.0", "32.0", "", "", "87.7", "79.1", "", "55.6", "", "2", "", "", "104", "1", "2", "12", "5", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.1", "96.4", "", "", "", "", "94.6"]} -{"pcdb_id": 18390, "brand_name": "Cosmogas", "model_name": "MYDENS", "model_qualifier": "60C", "winter_efficiency_pct": 87.8, "summer_efficiency_pct": 78.8, "comparative_hot_water_efficiency_pct": 57.5, "output_kw_max": 57.8, "final_year_of_manufacture": null, "raw": ["018390", "000309", "0", "2018/Apr/25 09:44", "Cosmogas srl", "Cosmogas", "MYDENS", "60C", "", "2013", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "57.8", "57.8", "", "", "87.8", "78.8", "", "57.5", "", "2", "", "", "102", "1", "2", "24", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.5", "96.4", "", "", "", "", "94.7"]} -{"pcdb_id": 18391, "brand_name": "Ariston", "model_name": "CLAS ONE 24", "model_qualifier": "", "winter_efficiency_pct": 89.7, "summer_efficiency_pct": 81.1, "comparative_hot_water_efficiency_pct": 57.1, "output_kw_max": 21.4, "final_year_of_manufacture": null, "raw": ["018391", "000080", "0", "2018/Dec/12 10:42", "Ariston Thermo S.p.A", "Ariston", "CLAS ONE 24", "", "3301043", "2017", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "21.4", "21.4", "", "", "89.7", "81.1", "", "57.1", "", "2", "0", "", "104", "1", "2", "30", "4", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0805", "", "", "", "", "", "", "", "", "89.4", "98.5", "", "", "", "", "96.7"]} -{"pcdb_id": 18394, "brand_name": "Vokera BY RIELLO", "model_name": "Easi-Heat Plus", "model_qualifier": "24S", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 24.18, "final_year_of_manufacture": null, "raw": ["018394", "000011", "0", "2019/Mar/06 09:44", "Vokera", "Vokera BY RIELLO", "Easi-Heat Plus", "24S", "20136547", "2017", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24.18", "24.18", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "43", "6", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.0", "97.2", "", "", "", "", "95.3"]} -{"pcdb_id": 18395, "brand_name": "Vokera BY RIELLO", "model_name": "Easi-Heat Plus", "model_qualifier": "30S", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 28.1, "final_year_of_manufacture": null, "raw": ["018395", "000011", "0", "2019/Mar/06 09:44", "Vokera", "Vokera BY RIELLO", "Easi-Heat Plus", "30S", "20136551", "2017", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "28.1", "28.1", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "50", "6", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "86.9", "97.3", "", "", "", "", "95.3"]} -{"pcdb_id": 18396, "brand_name": "Vokera BY RIELLO", "model_name": "Easi-Heat Plus", "model_qualifier": "18V", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 19.68, "final_year_of_manufacture": null, "raw": ["018396", "000011", "0", "2019/Jan/17 13:49", "Vokera", "Vokera BY RIELLO", "Easi-Heat Plus", "18V", "20136845", "2017", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "19.68", "19.68", "", "", "88.2", "79.2", "", "57.8", "", "2", "", "", "102", "1", "2", "75", "4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "97.3", "", "", "", "", "95.5"]} -{"pcdb_id": 18397, "brand_name": "Vaillant", "model_name": "ecoTEC exclusive 627", "model_qualifier": "VU 256/5-7 (H-GB)", "winter_efficiency_pct": 89.6, "summer_efficiency_pct": 80.6, "comparative_hot_water_efficiency_pct": 58.9, "output_kw_max": 25.0, "final_year_of_manufacture": null, "raw": ["018397", "000031", "0", "2018/Aug/21 09:27", "Vaillant", "Vaillant", "ecoTEC exclusive 627", "VU 256/5-7 (H-GB)", "41-694-02", "2016", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "25.0", "25.0", "", "", "89.6", "80.6", "", "58.9", "", "2", "0", "", "102", "1", "2", "32", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0045", "", "", "", "", "", "", "", "", "89.5", "98.0", "", "", "", "", "96.4"]} -{"pcdb_id": 18398, "brand_name": "Vaillant", "model_name": "ecoTEC exclusive 835", "model_qualifier": "VUW 356/5-7 (H-GB)", "winter_efficiency_pct": 89.6, "summer_efficiency_pct": 88.6, "comparative_hot_water_efficiency_pct": 86.0, "output_kw_max": 25.0, "final_year_of_manufacture": null, "raw": ["018398", "000031", "0", "2020/Jan/22 13:02", "Vaillant", "Vaillant", "ecoTEC exclusive 835", "VUW 356/5-7 (H-GB)", "47-044-66", "2016", "current", "2", "2", "1", "2", "1", "", "", "2", "2", "2", "25", "25", "", "", "89.6", "88.6", "", "86.0", "", "2", "0", "", "104", "1", "2", "31", "2", "0", "", "", "", "0", "", "", "", "", "1", "6.256", "0.074", "0.0051", "0.14701", "", "", "", "", "", "3", "1", "", "0045", "", "", "", "", "", "", "", "", "90.1", "97.8", "", "", "", "", "96.3"]} -{"pcdb_id": 18399, "brand_name": "Vaillant", "model_name": "ecoTEC exclusive 843", "model_qualifier": "VUW 436/5-7 (H-GB)", "winter_efficiency_pct": 89.8, "summer_efficiency_pct": 88.7, "comparative_hot_water_efficiency_pct": 86.4, "output_kw_max": 33.0, "final_year_of_manufacture": null, "raw": ["018399", "000031", "0", "2020/Jan/22 13:02", "Vaillant", "Vaillant", "ecoTEC exclusive 843", "VUW 436/5-7 (H-GB)", "47-044-67", "2016", "current", "2", "2", "1", "2", "1", "", "", "2", "2", "2", "33", "33", "", "", "89.8", "88.7", "", "86.4", "", "2", "0", "", "104", "1", "2", "45", "2", "0", "", "", "", "0", "", "", "", "", "1", "6.231", "0.092", "0.006", "0.12351", "", "", "", "", "", "3", "1", "", "0045", "", "", "", "", "", "", "", "", "90.4", "98.3", "", "", "", "", "96.8"]} -{"pcdb_id": 18400, "brand_name": "Vaillant", "model_name": "ecoFIT sustain 415", "model_qualifier": "VU 156/6-3 OV (H-GB)", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 15.3, "final_year_of_manufacture": null, "raw": ["018400", "000031", "0", "2018/Jun/27 11:01", "Vaillant", "Vaillant", "ecoFIT sustain 415", "VU 156/6-3 OV (H-GB)", "41-694-33", "2018", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "15.3", "15.3", "", "", "89.1", "80.1", "", "58.5", "", "2", "", "", "102", "1", "2", "24", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0045", "", "", "", "", "", "", "", "", "89.1", "99.1", "", "", "", "", "97.2"]} -{"pcdb_id": 18401, "brand_name": "Vaillant", "model_name": "ecoFIT sustain 418", "model_qualifier": "VU 186/6-3 OV (H-GB)", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 18.4, "final_year_of_manufacture": null, "raw": ["018401", "000031", "0", "2018/Jun/27 11:02", "Vaillant", "Vaillant", "ecoFIT sustain 418", "VU 186/6-3 OV (H-GB)", "41-694-34", "2018", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18.4", "18.4", "", "", "89.0", "80.0", "", "58.4", "", "2", "", "", "102", "1", "2", "25", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0045", "", "", "", "", "", "", "", "", "89.0", "98.9", "", "", "", "", "97.0"]} -{"pcdb_id": 18402, "brand_name": "Vaillant", "model_name": "ecoFIT sustain 430", "model_qualifier": "VU 306/6-3 OV (H-GB)", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 25.5, "final_year_of_manufacture": null, "raw": ["018402", "000031", "0", "2018/Jun/27 11:03", "Vaillant", "Vaillant", "ecoFIT sustain 430", "VU 306/6-3 OV (H-GB)", "41-694-35", "2018", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "25.5", "25.5", "", "", "89.1", "80.1", "", "58.5", "", "2", "", "", "102", "1", "2", "37", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0045", "", "", "", "", "", "", "", "", "89.5", "99.0", "", "", "", "", "97.2"]} -{"pcdb_id": 18403, "brand_name": "Vaillant", "model_name": "ecoFIT sustain 615", "model_qualifier": "VU 156/6-3 (H-GB)", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 15.3, "final_year_of_manufacture": null, "raw": ["018403", "000031", "0", "2018/Jun/27 11:03", "Vaillant", "Vaillant", "ecoFIT sustain 615", "VU 156/6-3 (H-GB)", "41-694-30", "2018", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "15.3", "15.3", "", "", "89.1", "80.1", "", "58.5", "", "2", "", "", "102", "1", "2", "24", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0045", "", "", "", "", "", "", "", "", "89.1", "99.1", "", "", "", "", "97.2"]} -{"pcdb_id": 18404, "brand_name": "Vaillant", "model_name": "ecoFIT sustain 618", "model_qualifier": "VU186/6-3 (H-GB)", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 18.4, "final_year_of_manufacture": null, "raw": ["018404", "000031", "0", "2018/Jun/27 11:03", "Vaillant", "Vaillant", "ecoFIT sustain 618", "VU186/6-3 (H-GB)", "41-694-31", "2018", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18.4", "18.4", "", "", "89.0", "80.0", "", "58.4", "", "2", "", "", "102", "1", "2", "25", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0045", "", "", "", "", "", "", "", "", "89.0", "98.9", "", "", "", "", "97.0"]} -{"pcdb_id": 18405, "brand_name": "Vaillant", "model_name": "ecoFIT sustain 630", "model_qualifier": "VU 306/6-3 (H-GB)", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 25.5, "final_year_of_manufacture": null, "raw": ["018405", "000031", "0", "2018/Jun/27 11:03", "Vaillant", "Vaillant", "ecoFIT sustain 630", "VU 306/6-3 (H-GB)", "41-694-32", "2018", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "25.5", "25.5", "", "", "89.1", "80.1", "", "58.5", "", "2", "", "", "102", "1", "2", "37", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0045", "", "", "", "", "", "", "", "", "89.5", "99.0", "", "", "", "", "97.2"]} -{"pcdb_id": 18406, "brand_name": "Worcester", "model_name": "GREENSTAR DANESMOOR", "model_qualifier": "12/18 ErP+", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 18.0, "final_year_of_manufacture": null, "raw": ["018406", "000035", "0", "2018/Aug/13 14:15", "Bosch Thermotechnology", "Worcester", "GREENSTAR DANESMOOR", "12/18 ErP+", "", "2018", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "12", "18", "", "", "87.9", "80.1", "", "58.5", "", "2", "", "", "201", "1", "1", "158", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "92.0", "94.0", "", "", "", "", "93.6"]} -{"pcdb_id": 18407, "brand_name": "Worcester", "model_name": "GREENSTAR DANESMOOR EXTERNAL", "model_qualifier": "12/18 ErP+", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 18.0, "final_year_of_manufacture": null, "raw": ["018407", "000035", "0", "2018/Aug/13 14:16", "Bosch Thermotechnology", "Worcester", "GREENSTAR DANESMOOR EXTERNAL", "12/18 ErP+", "", "2018", "current", "4", "1", "2", "1", "0", "", "", "2", "2", "2", "12", "18", "", "", "87.9", "80.1", "", "58.5", "", "2", "", "", "201", "1", "1", "158", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "92.0", "94.0", "", "", "", "", "93.6"]} -{"pcdb_id": 18408, "brand_name": "Worcester", "model_name": "GREENSTAR DANESMOOR UTILITY", "model_qualifier": "12/18 ErP+", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 18.0, "final_year_of_manufacture": null, "raw": ["018408", "000035", "0", "2018/Aug/13 14:16", "Bosch Thermotechnology", "Worcester", "GREENSTAR DANESMOOR UTILITY", "12/18 ErP+", "", "2018", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "12", "18", "", "", "87.9", "80.1", "", "58.5", "", "2", "", "", "201", "1", "1", "158", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "92.0", "94.0", "", "", "", "", "93.6"]} -{"pcdb_id": 18409, "brand_name": "Worcester", "model_name": "GREENSTAR DANESMOOR SYSTEM UTY", "model_qualifier": "12/18 ErP+", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 18.0, "final_year_of_manufacture": null, "raw": ["018409", "000035", "0", "2018/Aug/13 14:16", "Bosch Thermotechnology", "Worcester", "GREENSTAR DANESMOOR SYSTEM UTY", "12/18 ErP+", "", "2018", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "12", "18", "", "", "87.9", "80.1", "", "58.5", "", "2", "", "", "201", "1", "1", "158", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "92.0", "94.0", "", "", "", "", "93.6"]} -{"pcdb_id": 18410, "brand_name": "Worcester", "model_name": "GREENSTAR DANESMOOR SYSTEM EXTERNAL", "model_qualifier": "12/18 ErP+", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 18.0, "final_year_of_manufacture": null, "raw": ["018410", "000035", "0", "2018/Aug/13 14:17", "Bosch Thermotechnology", "Worcester", "GREENSTAR DANESMOOR SYSTEM EXTERNAL", "12/18 ErP+", "", "2018", "current", "4", "1", "2", "1", "0", "", "", "2", "2", "2", "12", "18", "", "", "87.9", "80.1", "", "58.5", "", "2", "", "", "201", "1", "1", "158", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "92.0", "94.0", "", "", "", "", "93.6"]} -{"pcdb_id": 18411, "brand_name": "Worcester", "model_name": "GREENSTAR DANESMOOR SYSTEM", "model_qualifier": "12/18 ErP+", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 18.0, "final_year_of_manufacture": null, "raw": ["018411", "000035", "0", "2018/Aug/13 14:17", "Bosch Thermotechnology", "Worcester", "GREENSTAR DANESMOOR SYSTEM", "12/18 ErP+", "", "2018", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "12", "18", "", "", "87.9", "80.1", "", "58.5", "", "2", "", "", "201", "1", "1", "158", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "92.0", "94.0", "", "", "", "", "93.6"]} -{"pcdb_id": 18412, "brand_name": "Worcester", "model_name": "GREENSTAR HEATSLAVE II", "model_qualifier": "12/18 ErP+", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 81.8, "comparative_hot_water_efficiency_pct": 42.6, "output_kw_max": 18.0, "final_year_of_manufacture": null, "raw": ["018412", "000035", "0", "2024/Jan/31 10:17", "Bosch Thermotechnology", "Worcester", "GREENSTAR HEATSLAVE II", "12/18 ErP+", "", "2018", "current", "4", "1", "1", "2", "0", "", "", "2", "3", "2", "12", "18", "", "", "87.9", "81.8", "", "42.6", "", "2", "", "", "203", "1", "1", "156", "2", "1", "1", "", "62", "0", "25", "3", "84", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "92.0", "94.0", "", "", "", "", "93.6"]} -{"pcdb_id": 18413, "brand_name": "Worcester", "model_name": "GREENSTAR HEATSLAVE II EXT", "model_qualifier": "12/18 ErP+", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 81.8, "comparative_hot_water_efficiency_pct": 42.6, "output_kw_max": 18.0, "final_year_of_manufacture": null, "raw": ["018413", "000035", "0", "2024/Jan/31 10:17", "Bosch Thermotechnology", "Worcester", "GREENSTAR HEATSLAVE II EXT", "12/18 ErP+", "", "2018", "current", "4", "1", "2", "2", "0", "", "", "2", "2", "2", "12", "18", "", "", "87.9", "81.8", "", "42.6", "", "2", "", "", "203", "1", "1", "156", "2", "1", "1", "", "62", "0", "25", "3", "84", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "92.0", "94.0", "", "", "", "", "93.6"]} -{"pcdb_id": 18414, "brand_name": "Worcester", "model_name": "GREENSTAR HEATSLAVE II EXTERNAL", "model_qualifier": "18/25 ErP+", "winter_efficiency_pct": 87.8, "summer_efficiency_pct": 81.7, "comparative_hot_water_efficiency_pct": 42.4, "output_kw_max": 25.0, "final_year_of_manufacture": null, "raw": ["018414", "000035", "0", "2024/Jan/31 10:17", "Bosch Thermotechnology", "Worcester", "GREENSTAR HEATSLAVE II EXTERNAL", "18/25 ErP+", "", "2018", "current", "4", "1", "2", "2", "0", "", "", "2", "2", "2", "18", "25", "", "", "87.8", "81.7", "", "42.4", "", "2", "", "", "203", "1", "1", "145", "2", "1", "1", "", "63", "0", "25", "3", "86", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.9", "93.8", "", "", "", "", "93.4"]} -{"pcdb_id": 18415, "brand_name": "Worcester", "model_name": "GREENSTAR HEATSLAVE II", "model_qualifier": "18/25 ErP+", "winter_efficiency_pct": 87.8, "summer_efficiency_pct": 81.7, "comparative_hot_water_efficiency_pct": 42.4, "output_kw_max": 25.0, "final_year_of_manufacture": null, "raw": ["018415", "000035", "0", "2024/Jan/31 10:17", "Bosch Thermotechnology", "Worcester", "GREENSTAR HEATSLAVE II", "18/25 ErP+", "", "2018", "current", "4", "1", "1", "2", "0", "", "", "2", "3", "2", "18", "25", "", "", "87.8", "81.7", "", "42.4", "", "2", "", "", "203", "1", "1", "145", "2", "1", "1", "", "63", "0", "25", "3", "86", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.9", "93.8", "", "", "", "", "93.4"]} -{"pcdb_id": 18416, "brand_name": "Worcester", "model_name": "GREENSTAR DANESMOOR", "model_qualifier": "18/25 ErP+", "winter_efficiency_pct": 87.8, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 25.0, "final_year_of_manufacture": null, "raw": ["018416", "000035", "0", "2018/Aug/13 14:18", "Bosch Thermotechnology", "Worcester", "GREENSTAR DANESMOOR", "18/25 ErP+", "", "2018", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "18", "25", "", "", "87.8", "80.0", "", "58.4", "", "2", "", "", "201", "1", "1", "152", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.9", "93.8", "", "", "", "", "93.4"]} -{"pcdb_id": 18417, "brand_name": "Worcester", "model_name": "GREENSTAR DANESMOOR EXTERNAL", "model_qualifier": "18/25 ErP+", "winter_efficiency_pct": 87.8, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 25.0, "final_year_of_manufacture": null, "raw": ["018417", "000035", "0", "2018/Aug/13 14:19", "Bosch Thermotechnology", "Worcester", "GREENSTAR DANESMOOR EXTERNAL", "18/25 ErP+", "", "2018", "current", "4", "1", "2", "1", "0", "", "", "2", "2", "2", "18", "25", "", "", "87.8", "80.0", "", "58.4", "", "2", "", "", "201", "1", "1", "152", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.9", "93.8", "", "", "", "", "93.4"]} -{"pcdb_id": 18418, "brand_name": "Worcester", "model_name": "GREENSTAR DANESMOOR SYSTEM EXTERNAL", "model_qualifier": "18/25 ErP+", "winter_efficiency_pct": 87.8, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 25.0, "final_year_of_manufacture": null, "raw": ["018418", "000035", "0", "2018/Aug/13 14:19", "Bosch Thermotechnology", "Worcester", "GREENSTAR DANESMOOR SYSTEM EXTERNAL", "18/25 ErP+", "", "2018", "current", "4", "1", "2", "1", "0", "", "", "2", "2", "2", "18", "25", "", "", "87.8", "80.0", "", "58.4", "", "2", "", "", "201", "1", "1", "152", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.9", "93.8", "", "", "", "", "93.4"]} -{"pcdb_id": 18419, "brand_name": "Worcester", "model_name": "GREENSTAR DANESMOOR SYSTEM", "model_qualifier": "18/25 ErP+", "winter_efficiency_pct": 87.8, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 25.0, "final_year_of_manufacture": null, "raw": ["018419", "000035", "0", "2018/Aug/13 14:19", "Bosch Thermotechnology", "Worcester", "GREENSTAR DANESMOOR SYSTEM", "18/25 ErP+", "", "2018", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "18", "25", "", "", "87.8", "80.0", "", "58.4", "", "2", "", "", "201", "1", "1", "152", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.9", "93.8", "", "", "", "", "93.4"]} -{"pcdb_id": 18420, "brand_name": "Worcester", "model_name": "GREENSTAR DANESMOOR UTILITY", "model_qualifier": "18/25 ErP+", "winter_efficiency_pct": 87.8, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 25.0, "final_year_of_manufacture": null, "raw": ["018420", "000035", "0", "2018/Aug/13 14:19", "Bosch Thermotechnology", "Worcester", "GREENSTAR DANESMOOR UTILITY", "18/25 ErP+", "", "2018", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "18", "25", "", "", "87.8", "80.0", "", "58.4", "", "2", "", "", "201", "1", "1", "152", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.9", "93.8", "", "", "", "", "93.4"]} -{"pcdb_id": 18421, "brand_name": "Worcester", "model_name": "GREENSTAR DANESMOOR SYSTEM UTY", "model_qualifier": "18/25 ErP+", "winter_efficiency_pct": 87.8, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 25.0, "final_year_of_manufacture": null, "raw": ["018421", "000035", "0", "2018/Aug/13 14:20", "Bosch Thermotechnology", "Worcester", "GREENSTAR DANESMOOR SYSTEM UTY", "18/25 ErP+", "", "2018", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "18", "25", "", "", "87.8", "80.0", "", "58.4", "", "2", "", "", "201", "1", "1", "152", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.9", "93.8", "", "", "", "", "93.4"]} -{"pcdb_id": 18422, "brand_name": "Worcester", "model_name": "GREENSTAR HEATSLAVE II", "model_qualifier": "25/32 ErP+", "winter_efficiency_pct": 87.7, "summer_efficiency_pct": 81.6, "comparative_hot_water_efficiency_pct": 42.2, "output_kw_max": 32.0, "final_year_of_manufacture": null, "raw": ["018422", "000035", "0", "2024/Jan/31 10:17", "Bosch Thermotechnology", "Worcester", "GREENSTAR HEATSLAVE II", "25/32 ErP+", "", "2018", "current", "4", "1", "1", "2", "0", "", "", "2", "3", "2", "25", "32", "", "", "87.7", "81.6", "", "42.2", "", "2", "", "", "203", "1", "1", "144", "2", "1", "1", "", "64", "0", "25", "3", "88", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.7", "93.7", "", "", "", "", "93.3"]} -{"pcdb_id": 18423, "brand_name": "Worcester", "model_name": "GREENSTAR HEATSLAVE II EXTERNAL", "model_qualifier": "25/32 ErP+", "winter_efficiency_pct": 87.7, "summer_efficiency_pct": 81.6, "comparative_hot_water_efficiency_pct": 42.2, "output_kw_max": 32.0, "final_year_of_manufacture": null, "raw": ["018423", "000035", "0", "2024/Jan/31 10:17", "Bosch Thermotechnology", "Worcester", "GREENSTAR HEATSLAVE II EXTERNAL", "25/32 ErP+", "", "2018", "current", "4", "1", "2", "2", "0", "", "", "2", "2", "2", "25", "32", "", "", "87.7", "81.6", "", "42.2", "", "2", "", "", "203", "1", "1", "144", "2", "1", "1", "", "64", "0", "25", "3", "88", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.7", "93.7", "", "", "", "", "93.3"]} -{"pcdb_id": 18424, "brand_name": "Worcester", "model_name": "GREENSTAR DANESMOOR", "model_qualifier": "25/32 ErP+", "winter_efficiency_pct": 87.7, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 32.0, "final_year_of_manufacture": null, "raw": ["018424", "000035", "0", "2018/Aug/13 14:21", "Bosch Thermotechnology", "Worcester", "GREENSTAR DANESMOOR", "25/32 ErP+", "", "2018", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "25", "32", "", "", "87.7", "79.9", "", "58.4", "", "2", "", "", "201", "1", "1", "147", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.7", "93.7", "", "", "", "", "93.3"]} -{"pcdb_id": 18425, "brand_name": "Worcester", "model_name": "GREENSTAR DANESMOOR EXTERNAL", "model_qualifier": "25/32 ErP+", "winter_efficiency_pct": 87.7, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 32.0, "final_year_of_manufacture": null, "raw": ["018425", "000035", "0", "2018/Aug/13 14:21", "Bosch Thermotechnology", "Worcester", "GREENSTAR DANESMOOR EXTERNAL", "25/32 ErP+", "", "2018", "current", "4", "1", "2", "1", "0", "", "", "2", "2", "2", "25", "32", "", "", "87.7", "79.9", "", "58.4", "", "2", "", "", "201", "1", "1", "147", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.7", "93.7", "", "", "", "", "93.3"]} -{"pcdb_id": 18426, "brand_name": "Worcester", "model_name": "GREENSTAR DANESMOOR SYSTEM EXTERNAL", "model_qualifier": "25/32 ErP+", "winter_efficiency_pct": 87.7, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 32.0, "final_year_of_manufacture": null, "raw": ["018426", "000035", "0", "2018/Aug/13 14:21", "Bosch Thermotechnology", "Worcester", "GREENSTAR DANESMOOR SYSTEM EXTERNAL", "25/32 ErP+", "", "2018", "current", "4", "1", "2", "1", "0", "", "", "2", "2", "2", "25", "32", "", "", "87.7", "79.9", "", "58.4", "", "2", "", "", "201", "1", "1", "147", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.7", "93.7", "", "", "", "", "93.3"]} -{"pcdb_id": 18427, "brand_name": "Worcester", "model_name": "GREENSTAR DANESMOOR SYSTEM", "model_qualifier": "25/32 ErP+", "winter_efficiency_pct": 87.7, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 32.0, "final_year_of_manufacture": null, "raw": ["018427", "000035", "0", "2018/Aug/13 14:22", "Bosch Thermotechnology", "Worcester", "GREENSTAR DANESMOOR SYSTEM", "25/32 ErP+", "", "2018", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "25", "32", "", "", "87.7", "79.9", "", "58.4", "", "2", "", "", "201", "1", "1", "147", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.7", "93.7", "", "", "", "", "93.3"]} -{"pcdb_id": 18428, "brand_name": "Worcester", "model_name": "GREENSTAR DANESMOOR UTILITY", "model_qualifier": "25/32 ErP+", "winter_efficiency_pct": 87.7, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 32.0, "final_year_of_manufacture": null, "raw": ["018428", "000035", "0", "2018/Aug/13 14:22", "Bosch Thermotechnology", "Worcester", "GREENSTAR DANESMOOR UTILITY", "25/32 ErP+", "", "2018", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "25", "32", "", "", "87.7", "79.9", "", "58.4", "", "2", "", "", "201", "1", "1", "147", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.7", "93.7", "", "", "", "", "93.3"]} -{"pcdb_id": 18429, "brand_name": "Worcester", "model_name": "GREENSTAR DANESMOOR SYSTEM UTY", "model_qualifier": "25/32 ErP+", "winter_efficiency_pct": 87.7, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 32.0, "final_year_of_manufacture": null, "raw": ["018429", "000035", "0", "2018/Aug/13 14:22", "Bosch Thermotechnology", "Worcester", "GREENSTAR DANESMOOR SYSTEM UTY", "25/32 ErP+", "", "2018", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "25", "32", "", "", "87.7", "79.9", "", "58.4", "", "2", "", "", "201", "1", "1", "147", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.7", "93.7", "", "", "", "", "93.3"]} -{"pcdb_id": 18430, "brand_name": "Worcester", "model_name": "GREENSTAR", "model_qualifier": "9Ri ErP+", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 9.0, "final_year_of_manufacture": null, "raw": ["018430", "000035", "0", "2018/Aug/13 09:14", "Bosch Thermotechnology", "Worcester", "GREENSTAR", "9Ri ErP+", "41-406-74", "2018", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "9.0", "9.0", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "25", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.2", "98.1", "", "", "", "", "96.0"]} -{"pcdb_id": 18431, "brand_name": "Worcester", "model_name": "GREENSTAR", "model_qualifier": "12Ri ErP+", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 12.0, "final_year_of_manufacture": null, "raw": ["018431", "000035", "0", "2018/Aug/13 09:14", "Bosch Thermotechnology", "Worcester", "GREENSTAR", "12Ri ErP+", "41-406-75", "2018", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "12", "12", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "33", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.2", "98.1", "", "", "", "", "96.0"]} -{"pcdb_id": 18432, "brand_name": "Worcester", "model_name": "GREENSTAR", "model_qualifier": "15Ri ErP+", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 15.0, "final_year_of_manufacture": null, "raw": ["018432", "000035", "0", "2018/Aug/13 09:15", "Bosch Thermotechnology", "Worcester", "GREENSTAR", "15Ri ErP+", "41-406-76", "2018", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "15", "15", "", "", "88.1", "79.1", "", "57.8", "", "2", "", "", "102", "1", "2", "44", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "86.9", "97.6", "", "", "", "", "95.6"]} -{"pcdb_id": 18433, "brand_name": "Worcester", "model_name": "GREENSTAR", "model_qualifier": "18Ri ErP+", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 18.0, "final_year_of_manufacture": null, "raw": ["018433", "000035", "0", "2018/Aug/13 09:15", "Bosch Thermotechnology", "Worcester", "GREENSTAR", "18Ri ErP+", "41-406-77", "2018", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18", "18", "", "", "88.1", "79.1", "", "57.8", "", "2", "", "", "102", "1", "2", "49", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "86.9", "97.6", "", "", "", "", "95.6"]} -{"pcdb_id": 18434, "brand_name": "Worcester", "model_name": "GREENSTAR", "model_qualifier": "21Ri ErP+", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 21.0, "final_year_of_manufacture": null, "raw": ["018434", "000035", "0", "2018/Aug/13 09:16", "Bosch Thermotechnology", "Worcester", "GREENSTAR", "21Ri ErP+", "41-406-78", "2018", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "21", "21", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "42", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "86.8", "97.2", "", "", "", "", "95.2"]} -{"pcdb_id": 18435, "brand_name": "Worcester", "model_name": "GREENSTAR", "model_qualifier": "24Ri ErP+", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 24.0, "final_year_of_manufacture": null, "raw": ["018435", "000035", "0", "2018/Aug/13 09:16", "Bosch Thermotechnology", "Worcester", "GREENSTAR", "24Ri ErP+", "41-406-79", "2018", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24", "24", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "51", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "86.8", "97.2", "", "", "", "", "95.2"]} -{"pcdb_id": 18436, "brand_name": "Worcester", "model_name": "GREENSTAR", "model_qualifier": "9Ri ErP+ LPG", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 9.0, "final_year_of_manufacture": null, "raw": ["018436", "000035", "0", "2018/Sep/05 10:10", "Bosch Thermotechnology", "Worcester", "GREENSTAR", "9Ri ErP+ LPG", "41-406-68", "2018", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "9", "9", "", "", "88.3", "79.3", "", "57.9", "", "2", "0", "", "102", "1", "2", "26", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.5", "94.8", "", "", "", "", "93.8"]} -{"pcdb_id": 18437, "brand_name": "Worcester", "model_name": "GREENSTAR", "model_qualifier": "12Ri ErP+ LPG", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 12.0, "final_year_of_manufacture": null, "raw": ["018437", "000035", "0", "2018/Sep/05 10:10", "Bosch Thermotechnology", "Worcester", "GREENSTAR", "12Ri ErP+ LPG", "41-406-69", "2018", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "12", "12", "", "", "88.3", "79.3", "", "57.9", "", "2", "0", "", "102", "1", "2", "36", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.5", "94.8", "", "", "", "", "93.8"]} -{"pcdb_id": 18438, "brand_name": "Worcester", "model_name": "GREENSTAR", "model_qualifier": "15Ri ErP+ LPG", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 15.0, "final_year_of_manufacture": null, "raw": ["018438", "000035", "0", "2018/Sep/05 10:11", "Bosch Thermotechnology", "Worcester", "GREENSTAR", "15Ri ErP+ LPG", "41-406-70", "2018", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "15", "15", "", "", "88.4", "79.4", "", "58.0", "", "2", "0", "", "102", "1", "2", "52", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.0", "95.0", "", "", "", "", "94.0"]} -{"pcdb_id": 18439, "brand_name": "Worcester", "model_name": "GREENSTAR", "model_qualifier": "18Ri ErP+ LPG", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 18.0, "final_year_of_manufacture": null, "raw": ["018439", "000035", "0", "2018/Sep/05 10:11", "Bosch Thermotechnology", "Worcester", "GREENSTAR", "18Ri ErP+ LPG", "41-406-71", "2018", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "18", "18", "", "", "88.5", "79.5", "", "58.1", "", "2", "0", "", "102", "1", "2", "55", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.7", "95.1", "", "", "", "", "94.1"]} -{"pcdb_id": 18440, "brand_name": "Worcester", "model_name": "GREENSTAR", "model_qualifier": "21Ri ErP+ LPG", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 21.0, "final_year_of_manufacture": null, "raw": ["018440", "000035", "0", "2018/Sep/05 10:11", "Bosch Thermotechnology", "Worcester", "GREENSTAR", "21Ri ErP+ LPG", "41-406-72", "2018", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "21", "21", "", "", "88.2", "79.2", "", "57.8", "", "2", "0", "", "102", "1", "2", "44", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.7", "94.3", "", "", "", "", "93.4"]} -{"pcdb_id": 18441, "brand_name": "Worcester", "model_name": "GREENSTAR", "model_qualifier": "24Ri ErP+ LPG", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 24.0, "final_year_of_manufacture": null, "raw": ["018441", "000035", "0", "2018/Sep/05 10:11", "Bosch Thermotechnology", "Worcester", "GREENSTAR", "24Ri ErP+ LPG", "41-406-73", "2018", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "24", "24", "", "", "88.2", "79.2", "", "57.8", "", "2", "0", "", "102", "1", "2", "54", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.7", "94.3", "", "", "", "", "93.4"]} -{"pcdb_id": 18442, "brand_name": "Worcester", "model_name": "Greenstar 8000 Style", "model_qualifier": "GR8700iW 30 C NG", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 88.2, "comparative_hot_water_efficiency_pct": 73.5, "output_kw_max": 29.5, "final_year_of_manufacture": null, "raw": ["018442", "000035", "0", "2020/Jul/27 16:45", "Bosch Thermotechnology", "Worcester", "Greenstar 8000 Style", "GR8700iW 30 C NG", "47-800-03", "2018", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "29.5", "29.5", "", "", "88.8", "88.2", "", "73.5", "", "2", "", "", "104", "1", "2", "67", "1", "0", "", "", "", "0", "", "", "", "", "2", "7.168", "0.098", "0.001", "1.05319", "13.007", "0.118", "0.001", "1.02566", "0.0", "", "", "", "8325", "", "", "", "", "", "", "", "", "88.3", "98.7", "", "", "", "", "96.7"]} -{"pcdb_id": 18443, "brand_name": "Worcester", "model_name": "Greenstar 8000 Style", "model_qualifier": "GR8700iW 35 C NG", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 88.2, "comparative_hot_water_efficiency_pct": 75.1, "output_kw_max": 33.7, "final_year_of_manufacture": null, "raw": ["018443", "000035", "0", "2020/Jul/27 16:39", "Bosch Thermotechnology", "Worcester", "Greenstar 8000 Style", "GR8700iW 35 C NG", "47-800-02", "2018", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "33.7", "33.7", "", "", "88.6", "88.2", "", "75.1", "", "2", "", "", "104", "1", "2", "48", "1", "0", "", "", "", "0", "", "", "", "", "2", "7.012", "0.103", "0.0045", "0.84809", "12.813", "0.118", "0.0005", "0.85555", "0.00004", "", "", "", "8325", "", "", "", "", "", "", "", "", "86.9", "98.8", "", "", "", "", "96.6"]} -{"pcdb_id": 18444, "brand_name": "Worcester", "model_name": "Greenstar 8000 Style", "model_qualifier": "GR8700iW 40 C NG", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 88.2, "comparative_hot_water_efficiency_pct": 73.4, "output_kw_max": 33.7, "final_year_of_manufacture": null, "raw": ["018444", "000035", "0", "2020/Jul/27 16:56", "Bosch Thermotechnology", "Worcester", "Greenstar 8000 Style", "GR8700iW 40 C NG", "47-800-01", "2018", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "33.7", "33.7", "", "", "88.7", "88.2", "", "73.4", "", "2", "", "", "104", "1", "2", "48", "1", "0", "", "", "", "0", "", "", "", "", "2", "7.175", "0.107", "0.001", "1.03647", "13.05", "0.126", "0.0005", "1.03238", "0.00001", "", "", "", "8325", "", "", "", "", "", "", "", "", "87.4", "98.7", "", "", "", "", "96.6"]} -{"pcdb_id": 18445, "brand_name": "Worcester", "model_name": "Greenstar 8000 Style", "model_qualifier": "GR8700iW 45 C NG", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 88.2, "comparative_hot_water_efficiency_pct": 74.1, "output_kw_max": 33.7, "final_year_of_manufacture": null, "raw": ["018445", "000035", "0", "2020/Jul/27 17:02", "Bosch Thermotechnology", "Worcester", "Greenstar 8000 Style", "GR8700iW 45 C NG", "47-406-99", "2018", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "33.7", "33.7", "", "", "88.9", "88.2", "", "74.1", "", "2", "", "", "104", "1", "2", "48", "1", "0", "", "", "", "0", "", "", "", "", "2", "7.103", "0.104", "0.0075", "0.96653", "12.953", "0.121", "0.0035", "0.92531", "0.00004", "", "", "", "8325", "", "", "", "", "", "", "", "", "88.8", "98.8", "", "", "", "", "96.9"]} -{"pcdb_id": 18446, "brand_name": "Worcester", "model_name": "Greenstar 8000 Style", "model_qualifier": "GR8700iW 50 C NG", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 88.2, "comparative_hot_water_efficiency_pct": 74.2, "output_kw_max": 33.7, "final_year_of_manufacture": null, "raw": ["018446", "000035", "0", "2020/Jul/27 17:06", "Bosch Thermotechnology", "Worcester", "Greenstar 8000 Style", "GR8700iW 50 C NG", "47-406-98", "2018", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "33.7", "33.7", "", "", "88.9", "88.2", "", "74.2", "", "2", "", "", "104", "1", "2", "48", "1", "0", "", "", "", "0", "", "", "", "", "2", "7.098", "0.101", "0.001", "0.9997", "12.909", "0.121", "0.001", "0.95851", "0.0", "", "", "", "8325", "", "", "", "", "", "", "", "", "88.8", "98.8", "", "", "", "", "96.9"]} -{"pcdb_id": 18447, "brand_name": "Worcester", "model_name": "Greenstar 8000 Style", "model_qualifier": "GR8700iW 30 CB NG", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 88.2, "comparative_hot_water_efficiency_pct": 73.5, "output_kw_max": 29.5, "final_year_of_manufacture": null, "raw": ["018447", "000035", "0", "2020/Jul/27 17:14", "Bosch Thermotechnology", "Worcester", "Greenstar 8000 Style", "GR8700iW 30 CB NG", "47-406-97", "2018", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "29.5", "29.5", "", "", "88.8", "88.2", "", "73.5", "", "2", "", "", "104", "1", "2", "67", "1", "0", "", "", "", "0", "", "", "", "", "2", "7.168", "0.098", "0.001", "1.05319", "13.007", "0.118", "0.001", "1.02566", "0.0", "", "", "", "8325", "", "", "", "", "", "", "", "", "88.3", "98.7", "", "", "", "", "96.7"]} -{"pcdb_id": 18448, "brand_name": "Worcester", "model_name": "Greenstar 8000 Style", "model_qualifier": "GR8700iW 35 CB NG", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 88.2, "comparative_hot_water_efficiency_pct": 75.1, "output_kw_max": 33.7, "final_year_of_manufacture": null, "raw": ["018448", "000035", "0", "2020/Jul/27 17:17", "Bosch Thermotechnology", "Worcester", "Greenstar 8000 Style", "GR8700iW 35 CB NG", "47-406-96", "2018", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "33.7", "33.7", "", "", "88.6", "88.2", "", "75.1", "", "2", "", "", "104", "1", "2", "48", "1", "0", "", "", "", "0", "", "", "", "", "2", "7.012", "0.103", "0.0045", "0.84809", "12.813", "0.118", "0.0005", "0.85555", "0.00004", "", "", "", "8325", "", "", "", "", "", "", "", "", "86.9", "98.8", "", "", "", "", "96.6"]} -{"pcdb_id": 18449, "brand_name": "Worcester", "model_name": "Greenstar 8000 Style", "model_qualifier": "GR8700iW 40 CB NG", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 88.2, "comparative_hot_water_efficiency_pct": 73.4, "output_kw_max": 33.7, "final_year_of_manufacture": null, "raw": ["018449", "000035", "0", "2020/Jul/27 17:21", "Bosch Thermotechnology", "Worcester", "Greenstar 8000 Style", "GR8700iW 40 CB NG", "47-406-95", "2018", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "33.7", "33.7", "", "", "88.7", "88.2", "", "73.4", "", "2", "", "", "104", "1", "2", "48", "1", "0", "", "", "", "0", "", "", "", "", "2", "7.175", "0.107", "0.001", "1.03647", "13.05", "0.126", "0.0005", "1.03238", "0.00001", "", "", "", "8325", "", "", "", "", "", "", "", "", "87.4", "98.7", "", "", "", "", "96.6"]} -{"pcdb_id": 18450, "brand_name": "Worcester", "model_name": "Greenstar 8000 Style", "model_qualifier": "GR8700iW 45 CB NG", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 88.2, "comparative_hot_water_efficiency_pct": 74.1, "output_kw_max": 33.7, "final_year_of_manufacture": null, "raw": ["018450", "000035", "0", "2020/Jul/27 17:25", "Bosch Thermotechnology", "Worcester", "Greenstar 8000 Style", "GR8700iW 45 CB NG", "47-406-94", "2018", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "33.7", "33.7", "", "", "88.9", "88.2", "", "74.1", "", "2", "", "", "104", "1", "2", "48", "1", "0", "", "", "", "0", "", "", "", "", "2", "7.103", "0.104", "0.0075", "0.96653", "12.953", "0.121", "0.0035", "0.92531", "0.00004", "", "", "", "8325", "", "", "", "", "", "", "", "", "88.8", "98.8", "", "", "", "", "96.9"]} -{"pcdb_id": 18451, "brand_name": "Worcester", "model_name": "Greenstar 8000 Style", "model_qualifier": "GR8700iW 50 CB NG", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 88.2, "comparative_hot_water_efficiency_pct": 74.2, "output_kw_max": 33.7, "final_year_of_manufacture": null, "raw": ["018451", "000035", "0", "2020/Jul/27 17:30", "Bosch Thermotechnology", "Worcester", "Greenstar 8000 Style", "GR8700iW 50 CB NG", "47-406-93", "2018", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "33.7", "33.7", "", "", "88.9", "88.2", "", "74.2", "", "2", "", "", "104", "1", "2", "48", "1", "0", "", "", "", "0", "", "", "", "", "2", "7.098", "0.101", "0.001", "0.9997", "12.909", "0.121", "0.001", "0.95851", "0.0", "", "", "", "8325", "", "", "", "", "", "", "", "", "88.8", "98.8", "", "", "", "", "96.9"]} -{"pcdb_id": 18452, "brand_name": "Worcester", "model_name": "Greenstar 8000 Style", "model_qualifier": "GR8700iW 30 S NG", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 29.5, "final_year_of_manufacture": null, "raw": ["018452", "000035", "0", "2020/Jan/22 13:03", "Bosch Thermotechnology", "Worcester", "Greenstar 8000 Style", "GR8700iW 30 S NG", "41-406-87", "2018", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "29.5", "29.5", "", "", "88.8", "79.8", "", "58.3", "", "2", "", "", "102", "1", "2", "67", "1", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "8325", "", "", "", "", "", "", "", "", "88.3", "98.7", "", "", "", "", "96.7"]} -{"pcdb_id": 18453, "brand_name": "Worcester", "model_name": "Greenstar 8000 Style", "model_qualifier": "GR8700iW 35 S NG", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 33.7, "final_year_of_manufacture": null, "raw": ["018453", "000035", "0", "2019/Aug/21 17:21", "Bosch Thermotechnology", "Worcester", "Greenstar 8000 Style", "GR8700iW 35 S NG", "41-406-86", "2018", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "33.7", "33.7", "", "", "88.6", "79.6", "", "58.2", "", "2", "", "", "102", "1", "2", "48", "1", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "8325", "", "", "", "", "", "", "", "", "86.9", "98.8", "", "", "", "", "96.6"]} -{"pcdb_id": 18454, "brand_name": "Worcester", "model_name": "Greenstar 8000 Style", "model_qualifier": "GR8700iW 30 SB NG", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 29.5, "final_year_of_manufacture": null, "raw": ["018454", "000035", "0", "2020/Apr/08 13:26", "Bosch Thermotechnology", "Worcester", "Greenstar 8000 Style", "GR8700iW 30 SB NG", "41-406-83", "2018", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "29.5", "29.5", "", "", "88.8", "79.8", "", "58.3", "", "2", "", "", "102", "1", "2", "67", "1", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "8325", "", "", "", "", "", "", "", "", "88.3", "98.7", "", "", "", "", "96.7"]} -{"pcdb_id": 18455, "brand_name": "Worcester", "model_name": "Greenstar 8000 Style", "model_qualifier": "GR8700iW 35 SB NG", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 33.7, "final_year_of_manufacture": null, "raw": ["018455", "000035", "0", "2019/Aug/22 14:11", "Bosch Thermotechnology", "Worcester", "Greenstar 8000 Style", "GR8700iW 35 SB NG", "41-406-82", "2018", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "33.7", "33.7", "", "", "88.6", "79.6", "", "58.2", "", "2", "", "", "102", "1", "2", "48", "1", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "8325", "", "", "", "", "", "", "", "", "86.9", "98.8", "", "", "", "", "96.6"]} -{"pcdb_id": 18456, "brand_name": "Worcester", "model_name": "Greenstar 8000 Style", "model_qualifier": "GR8700iW 30 C LPG", "winter_efficiency_pct": 90.5, "summer_efficiency_pct": 88.9, "comparative_hot_water_efficiency_pct": 74.1, "output_kw_max": 29.5, "final_year_of_manufacture": null, "raw": ["018456", "000035", "0", "2020/Jul/16 16:47", "Bosch Thermotechnology", "Worcester", "Greenstar 8000 Style", "GR8700iW 30 C LPG", "47-800-13", "2018", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "29.5", "29.5", "", "", "90.5", "88.9", "", "74.1", "", "2", "0", "", "104", "1", "2", "67", "1", "0", "", "", "", "0", "", "", "", "", "1", "7.261", "0.112", "0.008", "1.12085", "", "", "", "", "", "", "", "", "8325", "", "", "", "", "", "", "", "", "91.0", "99.7", "", "", "", "", "98.1"]} -{"pcdb_id": 18457, "brand_name": "Worcester", "model_name": "Greenstar 8000 Style", "model_qualifier": "GR8700iW 35 C LPG", "winter_efficiency_pct": 90.5, "summer_efficiency_pct": 88.9, "comparative_hot_water_efficiency_pct": 74.9, "output_kw_max": 33.7, "final_year_of_manufacture": null, "raw": ["018457", "000035", "0", "2020/Jul/16 16:50", "Bosch Thermotechnology", "Worcester", "Greenstar 8000 Style", "GR8700iW 35 C LPG", "47-800-12", "2018", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "33.7", "33.7", "", "", "90.5", "88.9", "", "74.9", "", "2", "0", "", "104", "1", "2", "48", "1", "0", "", "", "", "0", "", "", "", "", "1", "7.186", "0.109", "0.011", "1.02853", "", "", "", "", "", "", "", "", "8325", "", "", "", "", "", "", "", "", "90.9", "99.7", "", "", "", "", "98.1"]} -{"pcdb_id": 18458, "brand_name": "Worcester", "model_name": "Greenstar 8000 Style", "model_qualifier": "GR8700iW 40 C LPG", "winter_efficiency_pct": 90.4, "summer_efficiency_pct": 88.9, "comparative_hot_water_efficiency_pct": 73.5, "output_kw_max": 33.7, "final_year_of_manufacture": null, "raw": ["018458", "000035", "0", "2020/Jul/16 17:02", "Bosch Thermotechnology", "Worcester", "Greenstar 8000 Style", "GR8700iW 40 C LPG", "47-800-11", "2018", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "33.7", "33.7", "", "", "90.4", "88.9", "", "73.5", "", "2", "0", "", "104", "1", "2", "48", "1", "0", "", "", "", "0", "", "", "", "", "1", "7.323", "0.112", "0.01", "1.16904", "", "", "", "", "", "", "", "", "8325", "", "", "", "", "", "", "", "", "91.0", "99.6", "", "", "", "", "97.9"]} -{"pcdb_id": 18459, "brand_name": "Worcester", "model_name": "Greenstar 8000 Style", "model_qualifier": "GR8700iW 45 C LPG", "winter_efficiency_pct": 90.7, "summer_efficiency_pct": 89.1, "comparative_hot_water_efficiency_pct": 72.5, "output_kw_max": 33.7, "final_year_of_manufacture": null, "raw": ["018459", "000035", "0", "2020/Jul/16 17:06", "Bosch Thermotechnology", "Worcester", "Greenstar 8000 Style", "GR8700iW 45 C LPG", "47-800-10", "2018", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "33.7", "33.7", "", "", "90.7", "89.1", "", "72.5", "", "2", "0", "", "104", "1", "2", "48", "1", "0", "", "", "", "0", "", "", "", "", "1", "7.425", "0.106", "0.002", "1.32645", "", "", "", "", "", "", "", "", "8325", "", "", "", "", "", "", "", "", "91.5", "100.2", "", "", "", "", "98.5"]} -{"pcdb_id": 18460, "brand_name": "Worcester", "model_name": "Greenstar 8000 Style", "model_qualifier": "GR8700iW 50 C LPG", "winter_efficiency_pct": 90.6, "summer_efficiency_pct": 89.1, "comparative_hot_water_efficiency_pct": 74.5, "output_kw_max": 33.7, "final_year_of_manufacture": null, "raw": ["018460", "000035", "0", "2020/Jul/16 17:17", "Bosch Thermotechnology", "Worcester", "Greenstar 8000 Style", "GR8700iW 50 C LPG", "47-800-09", "2018", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "33.7", "33.7", "", "", "90.6", "89.1", "", "74.5", "", "2", "0", "", "104", "1", "2", "48", "1", "0", "", "", "", "0", "", "", "", "", "1", "7.228", "0.115", "0.0025", "1.13294", "", "", "", "", "", "", "", "", "8325", "", "", "", "", "", "", "", "", "91.5", "99.9", "", "", "", "", "98.3"]} -{"pcdb_id": 18461, "brand_name": "Worcester", "model_name": "Greenstar 8000 Style", "model_qualifier": "GR8700iW 30 S LPG", "winter_efficiency_pct": 90.5, "summer_efficiency_pct": 81.5, "comparative_hot_water_efficiency_pct": 59.5, "output_kw_max": 29.5, "final_year_of_manufacture": null, "raw": ["018461", "000035", "0", "2020/Apr/15 11:15", "Bosch Thermotechnology", "Worcester", "Greenstar 8000 Style", "GR8700iW 30 S LPG", "41-406-89", "2018", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "29.5", "29.5", "", "", "90.5", "81.5", "", "59.5", "", "2", "0", "", "102", "1", "2", "67", "1", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "8325", "", "", "", "", "", "", "", "", "91.0", "99.7", "", "", "", "", "98.1"]} -{"pcdb_id": 18462, "brand_name": "Worcester", "model_name": "Greenstar 8000 Style", "model_qualifier": "GR8700iW 35 S LPG", "winter_efficiency_pct": 90.5, "summer_efficiency_pct": 81.5, "comparative_hot_water_efficiency_pct": 59.5, "output_kw_max": 33.7, "final_year_of_manufacture": null, "raw": ["018462", "000035", "0", "2020/Apr/15 11:16", "Bosch Thermotechnology", "Worcester", "Greenstar 8000 Style", "GR8700iW 35 S LPG", "41-406-88", "2018", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "33.7", "33.7", "", "", "90.5", "81.5", "", "59.5", "", "2", "0", "", "102", "1", "2", "48", "1", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "8325", "", "", "", "", "", "", "", "", "90.9", "99.7", "", "", "", "", "98.1"]} -{"pcdb_id": 18463, "brand_name": "Worcester", "model_name": "Greenstar 8000 Style", "model_qualifier": "GR8700iW 30 CB LPG", "winter_efficiency_pct": 90.5, "summer_efficiency_pct": 88.9, "comparative_hot_water_efficiency_pct": 74.1, "output_kw_max": 29.5, "final_year_of_manufacture": null, "raw": ["018463", "000035", "0", "2020/Jul/16 17:31", "Bosch Thermotechnology", "Worcester", "Greenstar 8000 Style", "GR8700iW 30 CB LPG", "47-800-08", "2018", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "29.5", "29.5", "", "", "90.5", "88.9", "", "74.1", "", "2", "0", "", "104", "1", "2", "67", "1", "0", "", "", "", "0", "", "", "", "", "1", "7.261", "0.112", "0.008", "1.12085", "", "", "", "", "", "", "", "", "8325", "", "", "", "", "", "", "", "", "91.0", "99.7", "", "", "", "", "98.1"]} -{"pcdb_id": 18464, "brand_name": "Worcester", "model_name": "Greenstar 8000 Style", "model_qualifier": "GR8700iW 35 CB LPG", "winter_efficiency_pct": 90.5, "summer_efficiency_pct": 88.9, "comparative_hot_water_efficiency_pct": 74.9, "output_kw_max": 33.7, "final_year_of_manufacture": null, "raw": ["018464", "000035", "0", "2020/Jul/16 17:35", "Bosch Thermotechnology", "Worcester", "Greenstar 8000 Style", "GR8700iW 35 CB LPG", "47-800-07", "2018", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "33.7", "33.7", "", "", "90.5", "88.9", "", "74.9", "", "2", "0", "", "104", "1", "2", "48", "1", "0", "", "", "", "0", "", "", "", "", "1", "7.186", "0.109", "0.011", "1.02853", "", "", "", "", "", "", "", "", "8325", "", "", "", "", "", "", "", "", "90.9", "99.7", "", "", "", "", "98.1"]} -{"pcdb_id": 18465, "brand_name": "Worcester", "model_name": "Greenstar 8000 Style", "model_qualifier": "GR8700iW 40 CB LPG", "winter_efficiency_pct": 90.4, "summer_efficiency_pct": 88.9, "comparative_hot_water_efficiency_pct": 73.5, "output_kw_max": 33.7, "final_year_of_manufacture": null, "raw": ["018465", "000035", "0", "2020/Jul/16 17:42", "Bosch Thermotechnology", "Worcester", "Greenstar 8000 Style", "GR8700iW 40 CB LPG", "47-800-06", "2018", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "33.7", "33.7", "", "", "90.4", "88.9", "", "73.5", "", "2", "0", "", "104", "1", "2", "48", "1", "0", "", "", "", "0", "", "", "", "", "1", "7.323", "0.112", "0.01", "1.16904", "", "", "", "", "", "", "", "", "8325", "", "", "", "", "", "", "", "", "91.0", "99.6", "", "", "", "", "97.9"]} -{"pcdb_id": 18466, "brand_name": "Worcester", "model_name": "Greenstar 8000 Style", "model_qualifier": "GR8700iW 45 CB LPG", "winter_efficiency_pct": 90.7, "summer_efficiency_pct": 89.1, "comparative_hot_water_efficiency_pct": 72.5, "output_kw_max": 33.7, "final_year_of_manufacture": null, "raw": ["018466", "000035", "0", "2020/Jul/16 17:46", "Bosch Thermotechnology", "Worcester", "Greenstar 8000 Style", "GR8700iW 45 CB LPG", "47-800-05", "2018", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "33.7", "33.7", "", "", "90.7", "89.1", "", "72.5", "", "2", "0", "", "104", "1", "2", "48", "1", "0", "", "", "", "0", "", "", "", "", "1", "7.425", "0.106", "0.002", "1.32645", "", "", "", "", "", "", "", "", "8325", "", "", "", "", "", "", "", "", "91.5", "100.2", "", "", "", "", "98.5"]} -{"pcdb_id": 18467, "brand_name": "Worcester", "model_name": "Greenstar 8000 Style", "model_qualifier": "GR8700iW 50 CB LPG", "winter_efficiency_pct": 90.6, "summer_efficiency_pct": 89.1, "comparative_hot_water_efficiency_pct": 74.5, "output_kw_max": 33.7, "final_year_of_manufacture": null, "raw": ["018467", "000035", "0", "2020/Jul/16 17:47", "Bosch Thermotechnology", "Worcester", "Greenstar 8000 Style", "GR8700iW 50 CB LPG", "47-800-04", "2018", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "33.7", "33.7", "", "", "90.6", "89.1", "", "74.5", "", "2", "0", "", "104", "1", "2", "48", "1", "0", "", "", "", "0", "", "", "", "", "1", "7.228", "0.115", "0.0025", "1.13294", "", "", "", "", "", "", "", "", "8325", "", "", "", "", "", "", "", "", "91.5", "99.9", "", "", "", "", "98.3"]} -{"pcdb_id": 18468, "brand_name": "Worcester", "model_name": "Greenstar 8000 Style", "model_qualifier": "GR8700iW 30 SB LPG", "winter_efficiency_pct": 90.5, "summer_efficiency_pct": 81.5, "comparative_hot_water_efficiency_pct": 59.5, "output_kw_max": 29.5, "final_year_of_manufacture": null, "raw": ["018468", "000035", "0", "2020/Apr/15 11:17", "Bosch Thermotechnology", "Worcester", "Greenstar 8000 Style", "GR8700iW 30 SB LPG", "41-406-85", "2018", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "29.5", "29.5", "", "", "90.5", "81.5", "", "59.5", "", "2", "0", "", "102", "1", "2", "67", "1", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "8325", "", "", "", "", "", "", "", "", "91.0", "99.7", "", "", "", "", "98.1"]} -{"pcdb_id": 18469, "brand_name": "Worcester", "model_name": "Greenstar 8000 Style", "model_qualifier": "GR8700iW 35 SB LPG", "winter_efficiency_pct": 90.5, "summer_efficiency_pct": 81.5, "comparative_hot_water_efficiency_pct": 59.5, "output_kw_max": 33.7, "final_year_of_manufacture": null, "raw": ["018469", "000035", "0", "2020/Apr/15 11:17", "Bosch Thermotechnology", "Worcester", "Greenstar 8000 Style", "GR8700iW 35 SB LPG", "41-406-84", "2018", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "33.7", "33.7", "", "", "90.5", "81.5", "", "59.5", "", "2", "0", "", "102", "1", "2", "48", "1", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "8325", "", "", "", "", "", "", "", "", "90.9", "99.7", "", "", "", "", "98.1"]} -{"pcdb_id": 18470, "brand_name": "Ravenheat", "model_name": "HE 30 S Compact", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 55.9, "output_kw_max": 24.3, "final_year_of_manufacture": null, "raw": ["018470", "000026", "0", "2018/Oct/22 11:03", "Ravenheat Manufacturing", "Ravenheat", "HE 30 S Compact", "", "", "2018", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.3", "24.3", "", "", "88.0", "79.4", "", "55.9", "", "2", "", "", "104", "1", "2", "34", "5", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.5", "97.1", "", "", "", "", "95.3"]} -{"pcdb_id": 18471, "brand_name": "Ravenheat", "model_name": "HE 98 S", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 55.9, "output_kw_max": 24.3, "final_year_of_manufacture": null, "raw": ["018471", "000026", "0", "2018/Oct/22 11:03", "Ravenheat Manufacturing", "Ravenheat", "HE 98 S", "", "", "2017", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.3", "24.3", "", "", "88.0", "79.4", "", "55.9", "", "2", "", "", "104", "1", "2", "34", "5", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.5", "97.1", "", "", "", "", "95.3"]} -{"pcdb_id": 18472, "brand_name": "Firebird", "model_name": "Envirogreen Heatpac Condensing Boiler", "model_qualifier": "12-20kW", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 81.4, "comparative_hot_water_efficiency_pct": 59.5, "output_kw_max": 20.0, "final_year_of_manufacture": null, "raw": ["018472", "000047", "0", "2018/Sep/05 10:28", "Firebird Heating Solutions Ltd", "Firebird", "Envirogreen Heatpac Condensing Boiler", "12-20kW", "", "2018", "current", "4", "1", "2", "1", "0", "", "", "2", "2", "1", "12.0", "20.0", "", "", "89.2", "81.4", "", "59.5", "", "2", "", "", "201", "1", "1", "178", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "92.8", "97.1", "", "", "", "", "96.3"]} -{"pcdb_id": 18473, "brand_name": "Firebird", "model_name": "Envirogreen Heatpac Condensing Boiler", "model_qualifier": "20-26kW", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 81.2, "comparative_hot_water_efficiency_pct": 59.3, "output_kw_max": 26.0, "final_year_of_manufacture": null, "raw": ["018473", "000047", "0", "2018/Sep/05 10:29", "Firebird Heating Solutions Ltd", "Firebird", "Envirogreen Heatpac Condensing Boiler", "20-26kW", "", "2018", "current", "4", "1", "2", "1", "0", "", "", "2", "2", "1", "20", "26", "", "", "89.0", "81.2", "", "59.3", "", "2", "", "", "201", "1", "1", "184", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "92.7", "96.6", "", "", "", "", "95.9"]} -{"pcdb_id": 18474, "brand_name": "Firebird", "model_name": "Envirogreen Heatpac Condensing Boiler", "model_qualifier": "35kW", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 80.9, "comparative_hot_water_efficiency_pct": 59.1, "output_kw_max": 35.0, "final_year_of_manufacture": null, "raw": ["018474", "000047", "0", "2018/Sep/05 10:29", "Firebird Heating Solutions Ltd", "Firebird", "Envirogreen Heatpac Condensing Boiler", "35kW", "", "2018", "current", "4", "1", "2", "1", "0", "", "", "2", "2", "1", "26.0", "35.0", "", "", "88.7", "80.9", "", "59.1", "", "2", "", "", "201", "1", "1", "165", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "92.0", "96.1", "", "", "", "", "95.4"]} -{"pcdb_id": 18475, "brand_name": "Firebird", "model_name": "Envirogreen Kitchen Condensing Boiler", "model_qualifier": "12-20kW", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 81.4, "comparative_hot_water_efficiency_pct": 59.5, "output_kw_max": 20.0, "final_year_of_manufacture": null, "raw": ["018475", "000047", "0", "2018/Sep/05 10:29", "Firebird Heating Solutions Ltd", "Firebird", "Envirogreen Kitchen Condensing Boiler", "12-20kW", "", "2018", "current", "4", "1", "1", "1", "0", "", "", "2", "2", "1", "12.0", "20.0", "", "", "89.2", "81.4", "", "59.5", "", "2", "", "", "201", "1", "1", "178", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "92.8", "97.1", "", "", "", "", "96.3"]} -{"pcdb_id": 18476, "brand_name": "Firebird", "model_name": "Envirogreen Kitchen Condensing Boiler", "model_qualifier": "20-26kW", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 81.2, "comparative_hot_water_efficiency_pct": 59.3, "output_kw_max": 26.0, "final_year_of_manufacture": null, "raw": ["018476", "000047", "0", "2018/Sep/05 10:29", "Firebird Heating Solutions Ltd", "Firebird", "Envirogreen Kitchen Condensing Boiler", "20-26kW", "", "2018", "current", "4", "1", "1", "1", "0", "", "", "2", "2", "1", "20.0", "26.0", "", "", "89.0", "81.2", "", "59.3", "", "2", "", "", "201", "1", "1", "184", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "92.7", "96.6", "", "", "", "", "95.9"]} -{"pcdb_id": 18477, "brand_name": "Firebird", "model_name": "Envirogreen Kitchen Condensing Boiler", "model_qualifier": "35kW", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 80.9, "comparative_hot_water_efficiency_pct": 59.1, "output_kw_max": 35.0, "final_year_of_manufacture": null, "raw": ["018477", "000047", "0", "2018/Sep/05 10:30", "Firebird Heating Solutions Ltd", "Firebird", "Envirogreen Kitchen Condensing Boiler", "35kW", "", "2018", "current", "4", "1", "1", "1", "0", "", "", "2", "2", "1", "26.0", "35.0", "", "", "88.7", "80.9", "", "59.1", "", "2", "", "", "201", "1", "1", "165", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "92.0", "96.1", "", "", "", "", "95.4"]} -{"pcdb_id": 18478, "brand_name": "Firebird", "model_name": "Envirogreen Popular Condensing Boiler", "model_qualifier": "12-20kW", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 81.4, "comparative_hot_water_efficiency_pct": 59.5, "output_kw_max": 20.0, "final_year_of_manufacture": null, "raw": ["018478", "000047", "0", "2018/Sep/05 10:30", "Firebird Heating Solutions Ltd", "Firebird", "Envirogreen Popular Condensing Boiler", "12-20kW", "", "2018", "current", "4", "1", "1", "1", "0", "", "", "2", "2", "1", "12.0", "20.0", "", "", "89.2", "81.4", "", "59.5", "", "2", "", "", "201", "1", "1", "178", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "92.8", "97.1", "", "", "", "", "96.3"]} -{"pcdb_id": 18479, "brand_name": "Firebird", "model_name": "Envirogreen Popular Condensing Boiler", "model_qualifier": "20-26kW", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 81.2, "comparative_hot_water_efficiency_pct": 59.3, "output_kw_max": 26.0, "final_year_of_manufacture": null, "raw": ["018479", "000047", "0", "2018/Sep/05 10:30", "Firebird Heating Solutions Ltd", "Firebird", "Envirogreen Popular Condensing Boiler", "20-26kW", "", "2018", "current", "4", "1", "1", "1", "0", "", "", "2", "2", "1", "20.0", "26.0", "", "", "89.0", "81.2", "", "59.3", "", "2", "", "", "201", "1", "1", "184", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "92.7", "96.6", "", "", "", "", "95.9"]} -{"pcdb_id": 18480, "brand_name": "Firebird", "model_name": "Envirogreen Popular Condensing Boiler", "model_qualifier": "35kW", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 80.9, "comparative_hot_water_efficiency_pct": 59.1, "output_kw_max": 35.0, "final_year_of_manufacture": null, "raw": ["018480", "000047", "0", "2018/Sep/05 10:31", "Firebird Heating Solutions Ltd", "Firebird", "Envirogreen Popular Condensing Boiler", "35kW", "", "2018", "current", "4", "1", "1", "1", "0", "", "", "2", "2", "1", "26.0", "35.0", "", "", "88.7", "80.9", "", "59.1", "", "2", "", "", "201", "1", "1", "165", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "92.0", "96.1", "", "", "", "", "95.4"]} -{"pcdb_id": 18481, "brand_name": "Firebird", "model_name": "Envirogreen Slimline Heatpac Condensing", "model_qualifier": "12-20kW", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 81.4, "comparative_hot_water_efficiency_pct": 59.5, "output_kw_max": 20.0, "final_year_of_manufacture": null, "raw": ["018481", "000047", "0", "2018/Sep/05 10:31", "Firebird Heating Solutions Ltd", "Firebird", "Envirogreen Slimline Heatpac Condensing", "12-20kW", "", "2018", "current", "4", "1", "2", "1", "0", "", "", "2", "2", "1", "12.0", "20.0", "", "", "89.2", "81.4", "", "59.5", "", "2", "", "", "201", "1", "1", "178", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "92.8", "97.1", "", "", "", "", "96.3"]} -{"pcdb_id": 18482, "brand_name": "Firebird", "model_name": "Envirogreen Slimline Heatpac Condensing", "model_qualifier": "20-26", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 81.2, "comparative_hot_water_efficiency_pct": 59.3, "output_kw_max": 26.0, "final_year_of_manufacture": null, "raw": ["018482", "000047", "0", "2018/Sep/05 10:31", "Firebird Heating Solutions Ltd", "Firebird", "Envirogreen Slimline Heatpac Condensing", "20-26", "", "2018", "current", "4", "1", "2", "1", "0", "", "", "2", "2", "1", "20.0", "26.0", "", "", "89.0", "81.2", "", "59.3", "", "2", "", "", "201", "1", "1", "184", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "92.7", "96.6", "", "", "", "", "95.9"]} -{"pcdb_id": 18483, "brand_name": "Firebird", "model_name": "Envirogreen Slimline Heatpac Condensing", "model_qualifier": "35kW", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 80.9, "comparative_hot_water_efficiency_pct": 59.1, "output_kw_max": 35.0, "final_year_of_manufacture": null, "raw": ["018483", "000047", "0", "2018/Sep/05 10:31", "Firebird Heating Solutions Ltd", "Firebird", "Envirogreen Slimline Heatpac Condensing", "35kW", "", "2018", "current", "4", "1", "2", "1", "0", "", "", "2", "2", "1", "26.0", "35.0", "", "", "88.7", "80.9", "", "59.1", "", "2", "", "", "201", "1", "1", "165", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "92.0", "96.1", "", "", "", "", "95.4"]} -{"pcdb_id": 18484, "brand_name": "Alpha", "model_name": "E-Tec PLUS", "model_qualifier": "28", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 88.2, "comparative_hot_water_efficiency_pct": 75.2, "output_kw_max": 24.0, "final_year_of_manufacture": null, "raw": ["018484", "000001", "0", "2020/Apr/09 16:35", "Alpha Therm", "Alpha", "E-Tec PLUS", "28", "3.028466", "2018", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.0", "24.0", "", "", "88.3", "88.2", "", "75.2", "", "2", "", "", "104", "1", "2", "10", "2", "0", "", "", "", "0", "", "", "", "", "2", "7.002", "0.082", "0.0055", "0.86242", "12.57", "0.112", "0.0045", "0.84011", "0.00001", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.1", "97.6", "", "", "", "", "95.8"]} -{"pcdb_id": 18486, "brand_name": "Alpha", "model_name": "E-Tec PLUS", "model_qualifier": "33", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 88.2, "comparative_hot_water_efficiency_pct": 74.7, "output_kw_max": 28.0, "final_year_of_manufacture": null, "raw": ["018486", "000001", "0", "2020/Apr/09 16:34", "Alpha Therm", "Alpha", "E-Tec PLUS", "33", "3.028467", "2017", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28.0", "28.0", "", "", "88.4", "88.2", "", "74.7", "", "2", "", "", "104", "1", "2", "12", "2", "0", "", "", "", "0", "", "", "", "", "2", "7.051", "0.095", "0.0085", "0.89436", "12.849", "0.125", "0.004", "0.86958", "0.00005", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.2", "97.7", "", "", "", "", "95.9"]} -{"pcdb_id": 18487, "brand_name": "Alpha", "model_name": "E-Tec PLUS", "model_qualifier": "33 LPG", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 90.3, "comparative_hot_water_efficiency_pct": 77.1, "output_kw_max": 28.0, "final_year_of_manufacture": null, "raw": ["018487", "000001", "0", "2020/Apr/09 16:30", "Alpha Therm", "Alpha", "E-Tec PLUS", "33 LPG", "3.028467GPL", "2018", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "28.0", "28.0", "", "", "89.4", "90.3", "", "77.1", "", "2", "1", "", "104", "1", "2", "12", "2", "0", "", "", "", "0", "", "", "", "", "2", "6.979", "0.096", "0.0045", "0.84841", "12.541", "0.117", "0.004", "0.83445", "0.00001", "", "", "", "1005", "", "", "", "", "", "", "", "", "90.2", "99.8", "", "", "", "", "98.0"]} -{"pcdb_id": 18489, "brand_name": "Alpha", "model_name": "E-Tec", "model_qualifier": "30S", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 28.0, "final_year_of_manufacture": null, "raw": ["018489", "000001", "0", "2019/Apr/26 09:20", "Alpha Therm", "Alpha", "E-Tec", "30S", "3.028470", "2018", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "28.0", "28.0", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "12", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.2", "97.7", "", "", "", "", "95.9"]} -{"pcdb_id": 18490, "brand_name": "Alpha", "model_name": "E-Tec", "model_qualifier": "30S LPG", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 80.4, "comparative_hot_water_efficiency_pct": 58.7, "output_kw_max": 28.0, "final_year_of_manufacture": null, "raw": ["018490", "000001", "0", "2019/Sep/11 10:49", "Alpha Therm", "Alpha", "E-Tec", "30S LPG", "3.028470GPL", "2018", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "28.0", "28.0", "", "", "89.4", "80.4", "", "58.7", "", "2", "1", "", "102", "1", "2", "12", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "1005", "", "", "", "", "", "", "", "", "90.2", "99.8", "", "", "", "", "98.0"]} -{"pcdb_id": 18491, "brand_name": "Alpha", "model_name": "E-Tec", "model_qualifier": "20S", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 24.0, "final_year_of_manufacture": null, "raw": ["018491", "000001", "0", "2019/Apr/26 09:21", "Alpha Therm", "Alpha", "E-Tec", "20S", "3.028469", "2018", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24.0", "24.0", "", "", "88.3", "79.3", "", "57.9", "", "2", "", "", "102", "1", "2", "10", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.1", "97.6", "", "", "", "", "95.8"]} -{"pcdb_id": 18492, "brand_name": "Baxi", "model_name": "636 COMBI", "model_qualifier": "36", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 86.7, "comparative_hot_water_efficiency_pct": 81.4, "output_kw_max": 25.0, "final_year_of_manufacture": null, "raw": ["018492", "000005", "0", "2020/Jan/22 13:05", "Baxi Heating UK", "Baxi", "636 COMBI", "36", "47-077-30", "2018", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "25.0", "25.0", "", "", "88.4", "86.7", "", "81.4", "", "2", "", "", "104", "1", "2", "112", "3", "0", "", "", "", "0", "", "", "", "", "1", "6.471", "0.102", "0.0015", "0.37471", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "88.1", "97.8", "", "", "", "", "96.0"]} -{"pcdb_id": 18493, "brand_name": "Potterton", "model_name": "ASSURE", "model_qualifier": "36 COMBI", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 86.7, "comparative_hot_water_efficiency_pct": 81.4, "output_kw_max": 25.0, "final_year_of_manufacture": null, "raw": ["018493", "000005", "0", "2020/Jan/22 13:05", "Baxi Heating UK", "Potterton", "ASSURE", "36 COMBI", "47-393-67", "2018", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "25.0", "25.0", "", "", "88.4", "86.7", "", "81.4", "", "2", "", "", "104", "1", "2", "112", "3", "0", "", "", "", "0", "", "", "", "", "1", "6.471", "0.102", "0.0015", "0.37471", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "88.1", "97.8", "", "", "", "", "96.0"]} -{"pcdb_id": 18495, "brand_name": "Ideal", "model_name": "LOGIC MAX COMBI", "model_qualifier": "C24P", "winter_efficiency_pct": 90.1, "summer_efficiency_pct": 81.5, "comparative_hot_water_efficiency_pct": 57.3, "output_kw_max": 24.0, "final_year_of_manufacture": null, "raw": ["018495", "000008", "0", "2021/Jan/07 16:05", "Ideal Boilers", "Ideal", "LOGIC MAX COMBI", "C24P", "47-349-55", "2018", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24.0", "24.0", "", "", "90.1", "81.5", "", "57.3", "", "2", "1", "", "104", "1", "2", "42", "5", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "", "", "", "", "92.0", "100.8", "", "", "", "", "99.1"]} -{"pcdb_id": 18496, "brand_name": "Ideal", "model_name": "LOGIC MAX COMBI", "model_qualifier": "C30", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 70.4, "output_kw_max": 30.0, "final_year_of_manufacture": null, "raw": ["018496", "000008", "0", "2021/Jan/08 17:35", "Ideal Boilers", "Ideal", "LOGIC MAX COMBI", "C30", "47-349-57", "2018", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "30.0", "30.0", "", "", "89.0", "87.3", "", "70.4", "", "2", "", "", "104", "1", "2", "32", "5", "0", "", "", "", "0", "", "", "", "", "1", "7.476", "0.075", "0.0025", "1.38753", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "", "", "", "", "90.0", "98.6", "", "", "", "", "96.9"]} -{"pcdb_id": 18497, "brand_name": "Ideal", "model_name": "LOGIC MAX COMBI", "model_qualifier": "C30P", "winter_efficiency_pct": 90.1, "summer_efficiency_pct": 81.5, "comparative_hot_water_efficiency_pct": 57.3, "output_kw_max": 30.0, "final_year_of_manufacture": null, "raw": ["018497", "000008", "0", "2019/Oct/21 13:02", "Ideal Boilers", "Ideal", "LOGIC MAX COMBI", "C30P", "47-349-75", "2018", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "30.0", "30.0", "", "", "90.1", "81.5", "", "57.3", "", "2", "1", "", "104", "1", "2", "32", "5", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "", "", "", "", "92.0", "100.8", "", "", "", "", "99.1"]} -{"pcdb_id": 18498, "brand_name": "Ideal", "model_name": "LOGIC MAX COMBI", "model_qualifier": "C35", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 71.1, "output_kw_max": 35.0, "final_year_of_manufacture": null, "raw": ["018498", "000008", "0", "2020/Jan/22 13:07", "Ideal Boilers", "Ideal", "LOGIC MAX COMBI", "C35", "47-349-58", "2018", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "35.0", "35.0", "", "", "89.0", "87.3", "", "71.1", "", "2", "", "", "104", "1", "2", "29", "5", "0", "", "", "", "0", "", "", "", "", "1", "7.411", "0.074", "0.0025", "1.32452", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "", "", "", "", "90.0", "98.6", "", "", "", "", "96.9"]} -{"pcdb_id": 18499, "brand_name": "Ideal", "model_name": "LOGIC MAX HEAT", "model_qualifier": "H12", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 12.0, "final_year_of_manufacture": null, "raw": ["018499", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "LOGIC MAX HEAT", "H12", "41-796-17", "2018", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "12.0", "12.0", "", "", "88.8", "79.8", "", "58.3", "", "2", "", "", "102", "1", "2", "20", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "90.0", "97.9", "", "", "", "", "96.4"]} -{"pcdb_id": 18500, "brand_name": "Ideal", "model_name": "LOGIC MAX HEAT", "model_qualifier": "H15", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 15.0, "final_year_of_manufacture": null, "raw": ["018500", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "LOGIC MAX HEAT", "H15", "41-796-18", "2018", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "15.0", "15.0", "", "", "88.7", "79.7", "", "58.2", "", "2", "", "", "102", "1", "2", "21", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "90.0", "97.8", "", "", "", "", "96.4"]} -{"pcdb_id": 18501, "brand_name": "Ideal", "model_name": "LOGIC MAX HEAT", "model_qualifier": "H18", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 18.0, "final_year_of_manufacture": null, "raw": ["018501", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "LOGIC MAX HEAT", "H18", "41-796-19", "2018", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18.0", "18.0", "", "", "89.0", "80.0", "", "58.4", "", "2", "", "", "102", "1", "2", "26", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "90.0", "98.5", "", "", "", "", "96.9"]} -{"pcdb_id": 18502, "brand_name": "Ideal", "model_name": "LOGIC MAX HEAT", "model_qualifier": "H24", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 24.0, "final_year_of_manufacture": null, "raw": ["018502", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "LOGIC MAX HEAT", "H24", "41-796-20", "2018", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24.0", "24.0", "", "", "89.0", "80.0", "", "58.5", "", "2", "", "", "102", "1", "2", "42", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "90.0", "98.6", "", "", "", "", "96.9"]} -{"pcdb_id": 18503, "brand_name": "Ideal", "model_name": "LOGIC MAX HEAT", "model_qualifier": "H24P", "winter_efficiency_pct": 90.1, "summer_efficiency_pct": 81.1, "comparative_hot_water_efficiency_pct": 59.2, "output_kw_max": 24.0, "final_year_of_manufacture": null, "raw": ["018503", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "LOGIC MAX HEAT", "H24P", "41-796-20", "2018", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "24.0", "24.0", "", "", "90.1", "81.1", "", "59.2", "", "2", "1", "", "102", "1", "2", "42", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "92.0", "100.8", "", "", "", "", "99.1"]} -{"pcdb_id": 18504, "brand_name": "Ideal", "model_name": "LOGIC MAX HEAT", "model_qualifier": "H30", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 30.0, "final_year_of_manufacture": null, "raw": ["018504", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "LOGIC MAX HEAT", "H30", "41-796-21", "2018", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "30.0", "30.0", "", "", "88.8", "79.8", "", "58.3", "", "2", "", "", "102", "1", "2", "48", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "89.6", "98.2", "", "", "", "", "96.6"]} -{"pcdb_id": 18505, "brand_name": "Ideal", "model_name": "LOGIC MAX HEAT", "model_qualifier": "H30P", "winter_efficiency_pct": 89.8, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 59.1, "output_kw_max": 30.0, "final_year_of_manufacture": null, "raw": ["018505", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "LOGIC MAX HEAT", "H30P", "41-796-21", "2018", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "30.0", "30.0", "", "", "89.8", "80.8", "", "59.1", "", "2", "1", "", "102", "1", "2", "48", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "91.6", "100.4", "", "", "", "", "98.7"]} -{"pcdb_id": 18506, "brand_name": "Ideal", "model_name": "LOGIC MAX SYSTEM", "model_qualifier": "S15", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 15.0, "final_year_of_manufacture": null, "raw": ["018506", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "LOGIC MAX SYSTEM", "S15", "41-796-13", "2018", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "15.0", "15.0", "", "", "88.7", "79.7", "", "58.2", "", "2", "", "", "102", "1", "2", "21", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "90.0", "97.8", "", "", "", "", "96.4"]} -{"pcdb_id": 18507, "brand_name": "Ideal", "model_name": "LOGIC MAX SYSTEM", "model_qualifier": "S18", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 18.0, "final_year_of_manufacture": null, "raw": ["018507", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "LOGIC MAX SYSTEM", "S18", "41-796-14", "2018", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18.0", "18.0", "", "", "89.0", "80.0", "", "58.4", "", "2", "", "", "102", "1", "2", "26", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "89.8", "98.5", "", "", "", "", "96.8"]} -{"pcdb_id": 18508, "brand_name": "Ideal", "model_name": "LOGIC MAX SYSTEM", "model_qualifier": "S24", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 24.0, "final_year_of_manufacture": null, "raw": ["018508", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "LOGIC MAX SYSTEM", "S24", "41-796-15", "2018", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24.0", "24.0", "", "", "89.0", "80.0", "", "58.5", "", "2", "", "", "102", "1", "2", "42", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "90.0", "98.6", "", "", "", "", "96.9"]} -{"pcdb_id": 18509, "brand_name": "Ideal", "model_name": "LOGIC MAX SYSTEM", "model_qualifier": "S30", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 30.0, "final_year_of_manufacture": null, "raw": ["018509", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "LOGIC MAX SYSTEM", "S30", "41-796-16", "2018", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "30.0", "30.0", "", "", "88.8", "79.8", "", "58.3", "", "2", "", "", "102", "1", "2", "48", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "89.6", "98.2", "", "", "", "", "96.6"]} -{"pcdb_id": 18510, "brand_name": "Ideal", "model_name": "LOGIC MAX SYSTEM", "model_qualifier": "S30P", "winter_efficiency_pct": 89.8, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 59.1, "output_kw_max": 30.0, "final_year_of_manufacture": null, "raw": ["018510", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "LOGIC MAX SYSTEM", "S30P", "41-796-16", "2018", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "30.0", "30.0", "", "", "89.8", "80.8", "", "59.1", "", "2", "1", "", "102", "1", "2", "48", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "91.6", "100.4", "", "", "", "", "98.7"]} -{"pcdb_id": 18511, "brand_name": "Ideal", "model_name": "LOGIC MAX COMBI", "model_qualifier": "C24", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 69.8, "output_kw_max": 24.0, "final_year_of_manufacture": null, "raw": ["018511", "000008", "0", "2021/Jan/08 17:40", "Ideal Boilers", "Ideal", "LOGIC MAX COMBI", "C24", "47-349-56", "2018", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.0", "24.0", "", "", "89.0", "87.3", "", "69.8", "", "2", "", "", "104", "1", "2", "42", "5", "0", "", "", "", "0", "", "", "", "", "1", "7.549", "0.076", "0.0025", "1.4583", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "", "", "", "", "90.0", "98.6", "", "", "", "", "96.9"]} -{"pcdb_id": 18512, "brand_name": "Ideal", "model_name": "VOGUE MAX COMBI", "model_qualifier": "26", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 76.2, "output_kw_max": 26.0, "final_year_of_manufacture": null, "raw": ["018512", "000008", "0", "2021/Jan/08 17:45", "Ideal Boilers", "Ideal", "VOGUE MAX COMBI", "26", "47-349-59", "2018", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "26.0", "26.0", "", "", "88.6", "87.3", "", "76.2", "", "2", "", "", "104", "1", "2", "47", "3", "0", "", "", "", "0", "", "", "", "", "1", "6.915", "0.085", "0.001", "0.84569", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "", "", "", "", "89.7", "97.7", "", "", "", "", "96.2"]} -{"pcdb_id": 18513, "brand_name": "Ideal", "model_name": "VOGUE MAX COMBI", "model_qualifier": "26P", "winter_efficiency_pct": 89.6, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 57.0, "output_kw_max": 26.0, "final_year_of_manufacture": null, "raw": ["018513", "000008", "0", "2019/Oct/21 13:27", "Ideal Boilers", "Ideal", "VOGUE MAX COMBI", "26P", "47-349-59", "2018", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "26.0", "26.0", "", "", "89.6", "81.0", "", "57.0", "", "2", "1", "", "104", "1", "2", "47", "3", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "", "", "", "", "91.7", "99.8", "", "", "", "", "98.3"]} -{"pcdb_id": 18514, "brand_name": "Ideal", "model_name": "VOGUE MAX COMBI", "model_qualifier": "32", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 77.6, "output_kw_max": 32.0, "final_year_of_manufacture": null, "raw": ["018514", "000008", "0", "2021/Jan/08 17:49", "Ideal Boilers", "Ideal", "VOGUE MAX COMBI", "32", "47-349-60", "2018", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "32.0", "32.0", "", "", "88.7", "87.3", "", "77.6", "", "2", "", "", "104", "1", "2", "63", "3", "0", "", "", "", "0", "", "", "", "", "1", "6.79", "0.087", "0.001", "0.72908", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "", "", "", "", "89.9", "97.8", "", "", "", "", "96.3"]} -{"pcdb_id": 18515, "brand_name": "Ideal", "model_name": "VOGUE MAX COMBI", "model_qualifier": "32P", "winter_efficiency_pct": 89.7, "summer_efficiency_pct": 81.1, "comparative_hot_water_efficiency_pct": 57.1, "output_kw_max": 32.0, "final_year_of_manufacture": null, "raw": ["018515", "000008", "0", "2019/Oct/21 13:30", "Ideal Boilers", "Ideal", "VOGUE MAX COMBI", "32P", "47-349-60", "2018", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "32.0", "32.0", "", "", "89.7", "81.1", "", "57.1", "", "2", "1", "", "104", "1", "2", "63", "3", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "", "", "", "", "91.9", "100.0", "", "", "", "", "98.5"]} -{"pcdb_id": 18516, "brand_name": "Ideal", "model_name": "VOGUE MAX COMBI", "model_qualifier": "40", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 77.2, "output_kw_max": 40.0, "final_year_of_manufacture": null, "raw": ["018516", "000008", "0", "2021/Jan/08 17:51", "Ideal Boilers", "Ideal", "VOGUE MAX COMBI", "40", "47-349-61", "2018", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "40.0", "40.0", "", "", "88.6", "87.3", "", "77.2", "", "2", "", "", "104", "1", "2", "44", "3", "0", "", "", "", "0", "", "", "", "", "1", "6.821", "0.086", "0.001", "0.75466", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "", "", "", "", "89.7", "97.5", "", "", "", "", "96.0"]} -{"pcdb_id": 18517, "brand_name": "Ideal", "model_name": "VOGUE MAX COMBI", "model_qualifier": "40P", "winter_efficiency_pct": 89.6, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 56.9, "output_kw_max": 40.0, "final_year_of_manufacture": null, "raw": ["018517", "000008", "0", "2019/Oct/21 13:33", "Ideal Boilers", "Ideal", "VOGUE MAX COMBI", "40P", "47-349-61", "2018", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "40.0", "40.0", "", "", "89.6", "81.0", "", "56.9", "", "2", "1", "", "104", "1", "2", "44", "3", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "", "", "", "", "91.7", "99.7", "", "", "", "", "98.1"]} -{"pcdb_id": 18518, "brand_name": "Ideal", "model_name": "VOGUE MAX SYSTEM", "model_qualifier": "15", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 15.0, "final_year_of_manufacture": null, "raw": ["018518", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "VOGUE MAX SYSTEM", "15", "41-796-22", "2018", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "15.0", "15.0", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "25", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "89.6", "97.0", "", "", "", "", "95.6"]} -{"pcdb_id": 18519, "brand_name": "Ideal", "model_name": "VOGUE MAX SYSTEM", "model_qualifier": "15P", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 80.4, "comparative_hot_water_efficiency_pct": 58.7, "output_kw_max": 15.0, "final_year_of_manufacture": null, "raw": ["018519", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "VOGUE MAX SYSTEM", "15P", "41-796-22", "2018", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "15.0", "15.0", "", "", "89.4", "80.4", "", "58.7", "", "2", "1", "", "102", "1", "2", "25", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "91.5", "99.2", "", "", "", "", "97.7"]} -{"pcdb_id": 18520, "brand_name": "Ideal", "model_name": "VOGUE MAX SYSTEM", "model_qualifier": "18", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 18.0, "final_year_of_manufacture": null, "raw": ["018520", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "VOGUE MAX SYSTEM", "18", "41-796-23", "2018", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18.0", "18.0", "", "", "88.7", "79.7", "", "58.2", "", "2", "", "", "102", "1", "2", "40", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "89.8", "97.8", "", "", "", "", "96.3"]} -{"pcdb_id": 18521, "brand_name": "Ideal", "model_name": "VOGUE MAX SYSTEM", "model_qualifier": "18P", "winter_efficiency_pct": 89.7, "summer_efficiency_pct": 80.7, "comparative_hot_water_efficiency_pct": 59.0, "output_kw_max": 18.0, "final_year_of_manufacture": null, "raw": ["018521", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "VOGUE MAX SYSTEM", "18P", "41-796-23", "2018", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "18.0", "18.0", "", "", "89.7", "80.7", "", "59.0", "", "2", "1", "", "102", "1", "2", "40", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "91.8", "100.0", "", "", "", "", "98.5"]} -{"pcdb_id": 18522, "brand_name": "Ideal", "model_name": "VOGUE MAX SYSTEM", "model_qualifier": "26", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 26.0, "final_year_of_manufacture": null, "raw": ["018522", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "VOGUE MAX SYSTEM", "26", "41-796-24", "2018", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "26.0", "26.0", "", "", "88.7", "79.7", "", "58.2", "", "2", "", "", "102", "1", "2", "45", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "89.7", "97.8", "", "", "", "", "96.2"]} -{"pcdb_id": 18523, "brand_name": "Ideal", "model_name": "VOGUE MAX SYSTEM", "model_qualifier": "26P", "winter_efficiency_pct": 89.7, "summer_efficiency_pct": 80.7, "comparative_hot_water_efficiency_pct": 58.9, "output_kw_max": 26.0, "final_year_of_manufacture": null, "raw": ["018523", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "VOGUE MAX SYSTEM", "26P", "41-796-24", "2018", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "26.0", "26.0", "", "", "89.7", "80.7", "", "58.9", "", "2", "1", "", "102", "1", "2", "45", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "91.7", "99.9", "", "", "", "", "98.4"]} -{"pcdb_id": 18524, "brand_name": "Ideal", "model_name": "VOGUE MAX SYSTEM", "model_qualifier": "32", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 32.0, "final_year_of_manufacture": null, "raw": ["018524", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "VOGUE MAX SYSTEM", "32", "41-796-25", "2018", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "32.0", "32.0", "", "", "88.7", "79.7", "", "58.2", "", "2", "", "", "102", "1", "2", "49", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "89.8", "97.8", "", "", "", "", "96.3"]} -{"pcdb_id": 18525, "brand_name": "Ideal", "model_name": "VOGUE MAX SYSTEM", "model_qualifier": "32P", "winter_efficiency_pct": 89.7, "summer_efficiency_pct": 80.7, "comparative_hot_water_efficiency_pct": 59.0, "output_kw_max": 32.0, "final_year_of_manufacture": null, "raw": ["018525", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "VOGUE MAX SYSTEM", "32P", "41-796-25", "2018", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "32.0", "32.0", "", "", "89.7", "80.7", "", "59.0", "", "2", "1", "", "102", "1", "2", "49", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "91.8", "100.0", "", "", "", "", "98.5"]} -{"pcdb_id": 18526, "brand_name": "HRM", "model_name": "WALLSTAR1", "model_qualifier": "LOW NOX CONDENSING 12 - 16 Kw", "winter_efficiency_pct": 86.6, "summer_efficiency_pct": 78.8, "comparative_hot_water_efficiency_pct": 57.6, "output_kw_max": 16.0, "final_year_of_manufacture": null, "raw": ["018526", "000098", "0", "2019/Sep/10 13:23", "HRM Boilers", "HRM", "WALLSTAR1", "LOW NOX CONDENSING 12 - 16 Kw", "", "2018", "current", "4", "2", "1", "1", "0", "", "", "2", "2", "2", "12.0", "16.0", "", "", "86.6", "78.8", "", "57.6", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "89.4", "91.9", "", "", "", "", "91.4"]} -{"pcdb_id": 18527, "brand_name": "Sime", "model_name": "MURELLE REVOLUTION", "model_qualifier": "30", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 86.9, "comparative_hot_water_efficiency_pct": 64.9, "output_kw_max": 19.7, "final_year_of_manufacture": null, "raw": ["018527", "000213", "0", "2020/Jan/22 13:07", "Fonderie Sime S.p.A", "Sime", "MURELLE REVOLUTION", "30", "8116102", "2018", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "19.7", "19.7", "", "", "88.0", "86.9", "", "64.9", "", "2", "", "", "104", "1", "2", "29", "4", "0", "", "", "", "0", "", "", "", "", "1", "8.111", "0.279", "0.0008", "1.97056", "13.726", "0.295", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.6", "96.6", "", "", "", "", "95.1"]} -{"pcdb_id": 18528, "brand_name": "HRM", "model_name": "WALLSTAR2", "model_qualifier": "LOW NOX CONDENSING 12 - 20Kw", "winter_efficiency_pct": 87.8, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 20.0, "final_year_of_manufacture": null, "raw": ["018528", "000098", "0", "2019/Sep/10 13:35", "HRM Boilers", "HRM", "WALLSTAR2", "LOW NOX CONDENSING 12 - 20Kw", "", "2018", "current", "4", "2", "1", "1", "0", "", "", "2", "2", "2", "12", "20", "", "", "87.8", "80.0", "", "58.4", "", "2", "", "", "201", "1", "1", "130", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.3", "94.4", "", "", "", "", "93.7"]} -{"pcdb_id": 18529, "brand_name": "HRM", "model_name": "WALLSTAR3", "model_qualifier": "LOW NOX CONDENSING 20 - 24Kw", "winter_efficiency_pct": 87.2, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 24.0, "final_year_of_manufacture": null, "raw": ["018529", "000098", "0", "2019/Sep/10 13:40", "HRM Boilers", "HRM", "WALLSTAR3", "LOW NOX CONDENSING 20 - 24Kw", "", "2018", "current", "4", "2", "1", "1", "0", "", "", "2", "2", "2", "20", "24", "", "", "87.2", "79.4", "", "58.0", "", "2", "", "", "201", "1", "1", "139", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.1", "92.8", "", "", "", "", "92.4"]} -{"pcdb_id": 18530, "brand_name": "HRM", "model_name": "WALLSTAR COMBI", "model_qualifier": "LOW NOX CONDENSING", "winter_efficiency_pct": 87.4, "summer_efficiency_pct": 89.8, "comparative_hot_water_efficiency_pct": 49.4, "output_kw_max": 24.0, "final_year_of_manufacture": null, "raw": ["018530", "000098", "0", "2020/Jan/22 13:08", "HRM Boilers", "HRM", "WALLSTAR COMBI", "LOW NOX CONDENSING", "", "2018", "current", "4", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "87.4", "89.8", "", "49.4", "", "2", "", "", "202", "1", "1", "131", "1", "0", "", "", "", "0", "", "", "", "", "1", "11.092", "0.099", "0.0008", "4.77948", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.4", "93.3", "", "", "", "", "92.8"]} -{"pcdb_id": 18531, "brand_name": "HRM", "model_name": "WALLSTAR 2 SYSTEM", "model_qualifier": "LOW NOX CONDENSING 12 - 20Kw", "winter_efficiency_pct": 87.8, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 20.0, "final_year_of_manufacture": null, "raw": ["018531", "000098", "0", "2019/Sep/10 13:37", "HRM Boilers", "HRM", "WALLSTAR 2 SYSTEM", "LOW NOX CONDENSING 12 - 20Kw", "", "2018", "current", "4", "2", "1", "1", "0", "", "", "2", "2", "2", "12", "20", "", "", "87.8", "80.0", "", "58.4", "", "2", "", "", "201", "1", "1", "130", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.3", "94.4", "", "", "", "", "93.7"]} -{"pcdb_id": 18532, "brand_name": "EOGB", "model_name": "KERRO GREEN", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 80.6, "comparative_hot_water_efficiency_pct": 58.8, "output_kw_max": 20.5, "final_year_of_manufacture": null, "raw": ["018532", "000311", "0", "2019/Mar/18 14:05", "EOGB Energy Products Ltd", "EOGB", "KERRO GREEN", "", "", "2018", "current", "4", "1", "1", "1", "0", "", "", "2", "2", "2", "20.5", "20.5", "", "", "88.4", "80.6", "", "58.8", "", "2", "", "", "201", "1", "2", "109", "7", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "4005", "", "", "", "", "", "", "", "", "92.0", "95.2", "", "", "", "", "94.6"]} -{"pcdb_id": 18533, "brand_name": "Ariston", "model_name": "CLAS ONE 30", "model_qualifier": "", "winter_efficiency_pct": 89.7, "summer_efficiency_pct": 81.1, "comparative_hot_water_efficiency_pct": 57.0, "output_kw_max": 27.4, "final_year_of_manufacture": null, "raw": ["018533", "000080", "0", "2018/Dec/12 10:42", "Ariston Thermo S.p.A", "Ariston", "CLAS ONE 30", "", "3301044", "2017", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "27.4", "27.4", "", "", "89.7", "81.1", "", "57.0", "", "2", "0", "", "104", "1", "2", "39", "4", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0805", "", "", "", "", "", "", "", "", "89.9", "98.2", "", "", "", "", "96.6"]} -{"pcdb_id": 18534, "brand_name": "Ariston", "model_name": "CLAS ONE 38", "model_qualifier": "", "winter_efficiency_pct": 89.6, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 57.0, "output_kw_max": 30.2, "final_year_of_manufacture": null, "raw": ["018534", "000080", "0", "2018/Dec/12 10:43", "Ariston Thermo S.p.A", "Ariston", "CLAS ONE 38", "", "3301045", "2017", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "30.2", "30.2", "", "", "89.6", "81.0", "", "57.0", "", "2", "0", "", "104", "1", "2", "35", "4", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0805", "", "", "", "", "", "", "", "", "89.6", "98.1", "", "", "", "", "96.5"]} -{"pcdb_id": 18535, "brand_name": "Ariston", "model_name": "CLAS SYSTEM ONE 18", "model_qualifier": "", "winter_efficiency_pct": 89.7, "summer_efficiency_pct": 80.7, "comparative_hot_water_efficiency_pct": 59.0, "output_kw_max": 17.6, "final_year_of_manufacture": null, "raw": ["018535", "000080", "0", "2018/Dec/12 10:45", "Ariston Thermo S.p.A", "Ariston", "CLAS SYSTEM ONE 18", "", "3301046", "2017", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "17.6", "17.6", "", "", "89.7", "80.7", "", "59.0", "", "2", "0", "", "102", "1", "2", "24", "4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0805", "", "", "", "", "", "", "", "", "89.5", "98.4", "", "", "", "", "96.7"]} -{"pcdb_id": 18536, "brand_name": "Ariston", "model_name": "CLAS SYSTEM ONE 24", "model_qualifier": "", "winter_efficiency_pct": 89.7, "summer_efficiency_pct": 80.7, "comparative_hot_water_efficiency_pct": 59.0, "output_kw_max": 21.4, "final_year_of_manufacture": null, "raw": ["018536", "000080", "0", "2018/Dec/12 10:45", "Ariston Thermo S.p.A", "Ariston", "CLAS SYSTEM ONE 24", "", "3301047", "2017", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "21.4", "21.4", "", "", "89.7", "80.7", "", "59.0", "", "2", "0", "", "102", "1", "2", "30", "4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0805", "", "", "", "", "", "", "", "", "89.4", "98.5", "", "", "", "", "96.7"]} -{"pcdb_id": 18537, "brand_name": "Ariston", "model_name": "CLAS SYSTEM ONE 30", "model_qualifier": "", "winter_efficiency_pct": 89.7, "summer_efficiency_pct": 80.7, "comparative_hot_water_efficiency_pct": 58.9, "output_kw_max": 27.4, "final_year_of_manufacture": null, "raw": ["018537", "000080", "0", "2018/Dec/12 10:45", "Ariston Thermo S.p.A", "Ariston", "CLAS SYSTEM ONE 30", "", "3301048", "2017", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "27.4", "27.4", "", "", "89.7", "80.7", "", "58.9", "", "2", "0", "", "102", "1", "2", "35", "4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0805", "", "", "", "", "", "", "", "", "89.9", "98.2", "", "", "", "", "96.6"]} -{"pcdb_id": 18538, "brand_name": "Ariston", "model_name": "CLAS NET ONE 24", "model_qualifier": "", "winter_efficiency_pct": 89.7, "summer_efficiency_pct": 81.1, "comparative_hot_water_efficiency_pct": 57.1, "output_kw_max": 21.4, "final_year_of_manufacture": null, "raw": ["018538", "000080", "0", "2018/Dec/12 10:46", "Ariston Thermo S.p.A", "Ariston", "CLAS NET ONE 24", "", "3301049", "2017", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "21.4", "21.4", "", "", "89.7", "81.1", "", "57.1", "", "2", "0", "", "104", "1", "2", "30", "4", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0805", "", "", "", "", "", "", "", "", "89.4", "98.5", "", "", "", "", "96.7"]} -{"pcdb_id": 18539, "brand_name": "Ariston", "model_name": "CLAS NET ONE 30", "model_qualifier": "", "winter_efficiency_pct": 89.7, "summer_efficiency_pct": 81.1, "comparative_hot_water_efficiency_pct": 57.0, "output_kw_max": 27.4, "final_year_of_manufacture": null, "raw": ["018539", "000080", "0", "2018/Dec/12 10:46", "Ariston Thermo S.p.A", "Ariston", "CLAS NET ONE 30", "", "3301050", "2017", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "27.4", "27.4", "", "", "89.7", "81.1", "", "57.0", "", "2", "0", "", "104", "1", "2", "39", "4", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0805", "", "", "", "", "", "", "", "", "89.9", "98.2", "", "", "", "", "96.6"]} -{"pcdb_id": 18540, "brand_name": "Ariston", "model_name": "CLAS NET ONE 38", "model_qualifier": "", "winter_efficiency_pct": 89.6, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 57.0, "output_kw_max": 30.2, "final_year_of_manufacture": null, "raw": ["018540", "000080", "0", "2018/Dec/12 10:46", "Ariston Thermo S.p.A", "Ariston", "CLAS NET ONE 38", "", "3301051", "2017", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "30.2", "30.2", "", "", "89.6", "81.0", "", "57.0", "", "2", "0", "", "104", "1", "2", "35", "4", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0805", "", "", "", "", "", "", "", "", "89.6", "98.1", "", "", "", "", "96.5"]} -{"pcdb_id": 18541, "brand_name": "Ariston", "model_name": "E-SYSTEM ONE 24", "model_qualifier": "", "winter_efficiency_pct": 89.7, "summer_efficiency_pct": 80.7, "comparative_hot_water_efficiency_pct": 59.0, "output_kw_max": 21.4, "final_year_of_manufacture": null, "raw": ["018541", "000080", "0", "2018/Dec/12 10:46", "Ariston Thermo S.p.A", "Ariston", "E-SYSTEM ONE 24", "", "3301056", "2017", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "21.4", "21.4", "", "", "89.7", "80.7", "", "59.0", "", "2", "0", "", "102", "1", "2", "30", "4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0805", "", "", "", "", "", "", "", "", "89.4", "98.5", "", "", "", "", "96.7"]} -{"pcdb_id": 18542, "brand_name": "Ariston", "model_name": "E-SYSTEM ONE 30", "model_qualifier": "", "winter_efficiency_pct": 89.7, "summer_efficiency_pct": 80.7, "comparative_hot_water_efficiency_pct": 58.9, "output_kw_max": 27.4, "final_year_of_manufacture": null, "raw": ["018542", "000080", "0", "2018/Dec/12 10:47", "Ariston Thermo S.p.A", "Ariston", "E-SYSTEM ONE 30", "", "3301057", "2017", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "27.4", "27.4", "", "", "89.7", "80.7", "", "58.9", "", "2", "0", "", "102", "1", "2", "39", "4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0805", "", "", "", "", "", "", "", "", "89.9", "98.2", "", "", "", "", "96.6"]} -{"pcdb_id": 18543, "brand_name": "Ariston", "model_name": "E-COMBI ONE 24", "model_qualifier": "", "winter_efficiency_pct": 89.7, "summer_efficiency_pct": 81.1, "comparative_hot_water_efficiency_pct": 57.1, "output_kw_max": 21.4, "final_year_of_manufacture": null, "raw": ["018543", "000080", "0", "2018/Dec/12 10:47", "Ariston Thermo S.p.A", "Ariston", "E-COMBI ONE 24", "", "3301131", "2017", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "21.4", "21.4", "", "", "89.7", "81.1", "", "57.1", "", "2", "0", "", "104", "1", "2", "30", "4", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0805", "", "", "", "", "", "", "", "", "89.4", "98.5", "", "", "", "", "96.7"]} -{"pcdb_id": 18544, "brand_name": "Ariston", "model_name": "E-COMBI ONE 30", "model_qualifier": "", "winter_efficiency_pct": 89.7, "summer_efficiency_pct": 81.1, "comparative_hot_water_efficiency_pct": 57.0, "output_kw_max": 27.4, "final_year_of_manufacture": null, "raw": ["018544", "000080", "0", "2018/Dec/12 10:47", "Ariston Thermo S.p.A", "Ariston", "E-COMBI ONE 30", "", "3301132", "2017", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "27.4", "27.4", "", "", "89.7", "81.1", "", "57.0", "", "2", "0", "", "104", "1", "2", "39", "4", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0805", "", "", "", "", "", "", "", "", "89.9", "98.2", "", "", "", "", "96.6"]} -{"pcdb_id": 18546, "brand_name": "Ferroli", "model_name": "BLUEHELIX TECH RRT", "model_qualifier": "24C", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 86.8, "comparative_hot_water_efficiency_pct": 75.6, "output_kw_max": 20.0, "final_year_of_manufacture": null, "raw": ["018546", "000097", "0", "2020/Jan/22 13:08", "Ferroli", "Ferroli", "BLUEHELIX TECH RRT", "24C", "47-267-71", "2018", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "20.0", "20.0", "", "", "88.9", "86.8", "", "75.6", "", "2", "", "", "104", "1", "2", "22", "3", "0", "", "", "", "0", "", "", "", "", "1", "6.97", "0.119", "0.0066", "0.82777", "", "", "", "", "", "", "", "", "0015", "", "", "", "", "", "", "", "", "88.2", "99.0", "", "", "", "", "97.0"]} -{"pcdb_id": 18548, "brand_name": "Ferroli", "model_name": "BLUEHELIX TECH RRT", "model_qualifier": "28C", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 86.8, "comparative_hot_water_efficiency_pct": 76.0, "output_kw_max": 24.0, "final_year_of_manufacture": null, "raw": ["018548", "000097", "0", "2020/Jan/22 13:08", "Ferroli", "Ferroli", "BLUEHELIX TECH RRT", "28C", "47-267-72", "2018", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.0", "24.0", "", "", "88.8", "86.8", "", "76.0", "", "2", "", "", "104", "1", "2", "28", "3", "0", "", "", "", "0", "", "", "", "", "1", "6.93", "0.12", "0.0066", "0.78925", "", "", "", "", "", "", "", "", "0015", "", "", "", "", "", "", "", "", "88.2", "98.8", "", "", "", "", "96.8"]} -{"pcdb_id": 18550, "brand_name": "Ferroli", "model_name": "BLUEHELIX TECH RRT", "model_qualifier": "34C", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 86.7, "comparative_hot_water_efficiency_pct": 74.8, "output_kw_max": 30.0, "final_year_of_manufacture": null, "raw": ["018550", "000097", "0", "2020/Jan/22 13:08", "Ferroli", "Ferroli", "BLUEHELIX TECH RRT", "34C", "47-267-73", "2018", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "30.0", "30.0", "", "", "88.8", "86.7", "", "74.8", "", "2", "", "", "104", "1", "2", "36", "3", "0", "", "", "", "0", "", "", "", "", "1", "7.037", "0.118", "0.0066", "0.88998", "", "", "", "", "", "", "", "", "0015", "", "", "", "", "", "", "", "", "88.1", "98.8", "", "", "", "", "96.8"]} -{"pcdb_id": 18551, "brand_name": "Baxi", "model_name": "624 COMBI LPG", "model_qualifier": "24", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 56.8, "output_kw_max": 20.0, "final_year_of_manufacture": null, "raw": ["018551", "000005", "0", "2018/Nov/23 14:12", "Baxi Heating UK", "Baxi", "624 COMBI LPG", "24", "47-077-33", "2018", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "20.0", "20.0", "", "", "89.4", "80.8", "", "56.8", "", "2", "1", "", "104", "1", "2", "28", "3", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "90.0", "99.9", "", "", "", "", "98.0"]} -{"pcdb_id": 18552, "brand_name": "Baxi", "model_name": "630 COMBI LPG", "model_qualifier": "30", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 56.8, "output_kw_max": 20.0, "final_year_of_manufacture": null, "raw": ["018552", "000005", "0", "2018/Nov/23 14:13", "Baxi Heating", "Baxi", "630 COMBI LPG", "30", "47-077-32", "2018", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "20.0", "20.0", "", "", "89.4", "80.8", "", "56.8", "", "2", "1", "", "104", "1", "2", "38", "3", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "90.0", "99.9", "", "", "", "", "98.0"]} -{"pcdb_id": 18553, "brand_name": "Potterton", "model_name": "ASSURE 25 COMBI LPG", "model_qualifier": "25", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 56.8, "output_kw_max": 20.0, "final_year_of_manufacture": null, "raw": ["018553", "000005", "0", "2018/Dec/10 11:14", "Baxi Heating", "Potterton", "ASSURE 25 COMBI LPG", "25", "47-393-70", "2018", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "20.0", "20.0", "", "", "89.4", "80.8", "", "56.8", "", "2", "1", "", "104", "1", "2", "28", "3", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "90.0", "99.9", "", "", "", "", "98.0"]} -{"pcdb_id": 18554, "brand_name": "Potterton", "model_name": "ASSURE 30 COMBI LPG", "model_qualifier": "30", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 56.9, "output_kw_max": 25.0, "final_year_of_manufacture": null, "raw": ["018554", "000005", "0", "2019/Sep/12 10:16", "Baxi Heating", "Potterton", "ASSURE 30 COMBI LPG", "30", "47-393-69", "2018", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "25.0", "25.0", "", "", "89.4", "80.8", "", "56.9", "", "2", "1", "", "104", "1", "2", "38", "3", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "90.1", "100.0", "", "", "", "", "98.1"]} -{"pcdb_id": 18555, "brand_name": "Trianco", "model_name": "TRO EVOLUTION 20 KITCHEN HEAT ONLY", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 59.2, "output_kw_max": 20.0, "final_year_of_manufacture": null, "raw": ["018555", "000062", "0", "2018/Nov/14 16:10", "TR Engineering Ltd", "Trianco", "TRO EVOLUTION 20 KITCHEN HEAT ONLY", "", "", "2018", "current", "4", "1", "1", "1", "0", "", "", "2", "2", "2", "20.0", "20.0", "", "", "88.8", "81.0", "", "59.2", "", "2", "", "", "201", "1", "1", "217", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.1", "96.8", "", "", "", "", "95.7"]} -{"pcdb_id": 18556, "brand_name": "Trianco", "model_name": "TRO EVOLUTION 30 KITCHEN HEAT ONLY", "model_qualifier": "", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 81.1, "comparative_hot_water_efficiency_pct": 59.3, "output_kw_max": 30.0, "final_year_of_manufacture": null, "raw": ["018556", "000062", "0", "2018/Nov/14 16:10", "TR Engineering Ltd", "Trianco", "TRO EVOLUTION 30 KITCHEN HEAT ONLY", "", "", "2018", "current", "4", "1", "1", "1", "0", "", "", "2", "2", "2", "30.0", "30.0", "", "", "88.9", "81.1", "", "59.3", "", "2", "", "", "201", "1", "1", "217", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.9", "97.2", "", "", "", "", "96.0"]} -{"pcdb_id": 18557, "brand_name": "Sime", "model_name": "MURELLE ONE HE", "model_qualifier": "30", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 75.7, "comparative_hot_water_efficiency_pct": 62.1, "output_kw_max": 23.7, "final_year_of_manufacture": null, "raw": ["018557", "000213", "0", "2020/Apr/09 16:21", "Fonderie Sime", "Sime", "MURELLE ONE HE", "30", "8115012", "2018", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "23.7", "23.7", "", "", "88.5", "75.7", "", "62.1", "", "2", "", "", "104", "1", "2", "32", "4", "0", "", "", "", "0", "", "", "", "", "2", "8.478", "0.114", "0.0", "2.3402", "15.446", "0.127", "0.0035", "1.13131", "-0.00004", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.9", "97.8", "", "", "", "", "96.1"]} -{"pcdb_id": 18559, "brand_name": "Main", "model_name": "ECO COMPACT 25 COMBI", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 56.1, "output_kw_max": 20.0, "final_year_of_manufacture": null, "raw": ["018559", "000005", "0", "2018/Dec/13 10:26", "Baxi Heating", "Main", "ECO COMPACT 25 COMBI", "", "47-467-14", "2018", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "20.0", "20.0", "", "", "88.4", "79.8", "", "56.1", "", "2", "", "", "104", "1", "2", "28", "3", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "88.0", "97.8", "", "", "", "", "95.9"]} -{"pcdb_id": 18560, "brand_name": "Main", "model_name": "ECO COMPACT 30 COMBI", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 56.1, "output_kw_max": 25.0, "final_year_of_manufacture": null, "raw": ["018560", "000005", "0", "2018/Dec/13 10:26", "Baxi Heating", "Main", "ECO COMPACT 30 COMBI", "", "47-467-15", "2018", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "25.0", "25.0", "", "", "88.4", "79.8", "", "56.1", "", "2", "", "", "104", "1", "2", "28", "3", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "88.0", "97.8", "", "", "", "", "95.9"]} -{"pcdb_id": 18561, "brand_name": "Main", "model_name": "ECO COMPACT 15 SYSTEM", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 15.0, "final_year_of_manufacture": null, "raw": ["018561", "000005", "0", "2018/Dec/13 09:27", "Baxi Heating", "Main", "ECO COMPACT 15 SYSTEM", "", "41-467-30", "2018", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "15.0", "15.0", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "25", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "88.2", "97.8", "", "", "", "", "95.9"]} -{"pcdb_id": 18562, "brand_name": "Main", "model_name": "ECO COMPACT 18 SYSTEM", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 18.0, "final_year_of_manufacture": null, "raw": ["018562", "000005", "0", "2018/Dec/13 09:27", "Baxi Heating", "Main", "ECO COMPACT 18 SYSTEM", "", "47-467-31", "2018", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18.0", "18.0", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "25", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "88.2", "97.8", "", "", "", "", "96.0"]} -{"pcdb_id": 18563, "brand_name": "Worcester", "model_name": "GREENSTAR UTILITY REGULAR ErP+", "model_qualifier": "50/70", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 70.0, "final_year_of_manufacture": null, "raw": ["018563", "000035", "0", "2018/Nov/26 16:42", "Bosch Thermotechnology", "Worcester", "GREENSTAR UTILITY REGULAR ErP+", "50/70", "", "2018", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "50.0", "70.0", "", "", "88.0", "80.2", "", "58.6", "", "2", "", "", "201", "1", "1", "182", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.4", "94.5", "", "", "", "", "93.9"]} -{"pcdb_id": 18564, "brand_name": "Ariston", "model_name": "CARES ONE 24", "model_qualifier": "", "winter_efficiency_pct": 87.7, "summer_efficiency_pct": 85.1, "comparative_hot_water_efficiency_pct": 75.2, "output_kw_max": 21.3, "final_year_of_manufacture": null, "raw": ["018564", "000080", "0", "2020/Jan/22 13:08", "Ariston Thermo S.p.A", "Ariston", "CARES ONE 24", "", "3301054", "2017", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "21.3", "21.3", "", "", "87.7", "85.1", "", "75.2", "", "2", "", "", "104", "1", "2", "33", "4", "0", "", "", "", "0", "", "", "", "", "1", "7.006", "0.121", "0.003", "0.75113", "", "", "", "", "", "", "", "", "0805", "", "", "", "", "", "", "", "", "85.1", "98.1", "", "", "", "", "95.6"]} -{"pcdb_id": 18565, "brand_name": "Ariston", "model_name": "CARES ONE 30", "model_qualifier": "", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 86.8, "comparative_hot_water_efficiency_pct": 72.7, "output_kw_max": 27.4, "final_year_of_manufacture": null, "raw": ["018565", "000080", "0", "2020/Jan/22 13:08", "Ariston Thermo S.p.A", "Ariston", "CARES ONE 30", "", "3301055", "2017", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "27.4", "27.4", "", "", "88.9", "86.8", "", "72.7", "", "2", "", "", "104", "1", "2", "40", "4", "0", "", "", "", "0", "", "", "", "", "1", "7.239", "0.14", "0.007", "1.08414", "", "", "", "", "", "", "", "", "0805", "", "", "", "", "", "", "", "", "88.2", "98.9", "", "", "", "", "96.9"]} -{"pcdb_id": 18566, "brand_name": "Vaillant", "model_name": "ecoFIT pure 830 P", "model_qualifier": "VUW 306/6-3 (P-GB)", "winter_efficiency_pct": 90.4, "summer_efficiency_pct": 81.8, "comparative_hot_water_efficiency_pct": 57.5, "output_kw_max": 30.6, "final_year_of_manufacture": null, "raw": ["018566", "000031", "0", "2019/Feb/18 16:30", "Vaillant", "Vaillant", "ecoFIT pure 830 P", "VUW 306/6-3 (P-GB)", "47-044-75", "2018", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "30.6", "30.6", "", "", "90.4", "81.8", "", "57.5", "", "2", "0", "", "104", "1", "2", "31", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0045", "", "", "", "", "", "", "", "", "90.7", "99.7", "", "", "", "", "98.0"]} -{"pcdb_id": 18567, "brand_name": "Worcester", "model_name": "Greenstar Utility Regular 32/50 ErP +", "model_qualifier": "", "winter_efficiency_pct": 87.5, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 50.0, "final_year_of_manufacture": null, "raw": ["018567", "000035", "0", "2019/Jan/02 15:38", "Bosch Thermotechnology", "Worcester", "Greenstar Utility Regular 32/50 ErP +", "", "", "2018", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "32", "50", "", "", "87.5", "79.7", "", "58.2", "", "2", "", "", "201", "1", "1", "192", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.2", "93.4", "", "", "", "", "93.0"]} -{"pcdb_id": 18568, "brand_name": "Ariston", "model_name": "ALTEAS ONE NET 30", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 86.9, "comparative_hot_water_efficiency_pct": 73.0, "output_kw_max": 27.5, "final_year_of_manufacture": null, "raw": ["018568", "000080", "0", "2020/Jan/22 13:09", "Ariston Thermo S.p.A", "Ariston", "ALTEAS ONE NET 30", "", "3301449", "2017", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "27.5", "27.5", "", "", "88.8", "86.9", "", "73.0", "", "2", "", "", "104", "1", "2", "42", "5", "0", "", "", "", "0", "", "", "", "", "1", "7.213", "0.166", "0.008", "1.06506", "", "", "", "", "", "", "", "", "0805", "", "", "", "", "", "", "", "", "88.7", "98.7", "", "", "", "", "96.8"]} -{"pcdb_id": 18569, "brand_name": "Ariston", "model_name": "ALTEAS ONE NET 35", "model_qualifier": "", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 86.7, "comparative_hot_water_efficiency_pct": 73.0, "output_kw_max": 31.0, "final_year_of_manufacture": null, "raw": ["018569", "000080", "0", "2020/Jan/22 13:09", "Ariston Thermo S.p.A", "Ariston", "ALTEAS ONE NET 35", "", "3301450", "2017", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "31.0", "31.0", "", "", "88.7", "86.7", "", "73.0", "", "2", "", "", "104", "1", "2", "42", "5", "0", "", "", "", "0", "", "", "", "", "1", "7.211", "0.157", "0.0041", "1.06942", "", "", "", "", "", "", "", "", "0805", "", "", "", "", "", "", "", "", "88.0", "98.7", "", "", "", "", "96.6"]} -{"pcdb_id": 18570, "brand_name": "Ariston", "model_name": "GENUS ONE NET 30", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 86.9, "comparative_hot_water_efficiency_pct": 73.0, "output_kw_max": 27.5, "final_year_of_manufacture": null, "raw": ["018570", "000080", "0", "2020/Jan/22 13:09", "Ariston Thermo S.p.A", "Ariston", "GENUS ONE NET 30", "", "3301452", "2017", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "27.5", "27.5", "", "", "88.8", "86.9", "", "73.0", "", "2", "", "", "104", "1", "2", "42", "5", "0", "", "", "", "0", "", "", "", "", "1", "7.213", "0.166", "0.0082", "1.06389", "", "", "", "", "", "", "", "", "0805", "", "", "", "", "", "", "", "", "88.7", "98.7", "", "", "", "", "96.8"]} -{"pcdb_id": 18571, "brand_name": "Ariston", "model_name": "GENUS ONE NET 24", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 86.7, "comparative_hot_water_efficiency_pct": 70.9, "output_kw_max": 21.5, "final_year_of_manufacture": null, "raw": ["018571", "000080", "0", "2020/Jan/22 13:09", "Ariston Thermo S.p.A", "Ariston", "GENUS ONE NET 24", "", "3301451", "2017", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "21.5", "21.5", "", "", "88.8", "86.7", "", "70.9", "", "2", "", "", "104", "1", "2", "33", "6", "0", "", "", "", "0", "", "", "", "", "1", "7.432", "0.128", "0.008", "1.25927", "", "", "", "", "", "", "", "", "0805", "", "", "", "", "", "", "", "", "88.0", "98.9", "", "", "", "", "96.9"]} -{"pcdb_id": 18572, "brand_name": "Ariston", "model_name": "GENUS ONE NET 35", "model_qualifier": "", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 86.7, "comparative_hot_water_efficiency_pct": 73.0, "output_kw_max": 31.0, "final_year_of_manufacture": null, "raw": ["018572", "000080", "0", "2020/Jan/22 13:09", "Ariston Thermo S.p.A", "Ariston", "GENUS ONE NET 35", "", "3301453", "2017", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "31.0", "31.0", "", "", "88.7", "86.7", "", "73.0", "", "2", "", "", "104", "1", "2", "42", "5", "0", "", "", "", "0", "", "", "", "", "1", "7.211", "0.157", "0.0041", "1.06942", "", "", "", "", "", "", "", "", "0805", "", "", "", "", "", "", "", "", "88.0", "98.7", "", "", "", "", "96.6"]} -{"pcdb_id": 18573, "brand_name": "Firebird", "model_name": "Envirogreen Combi HE Condensing Boiler", "model_qualifier": "20kW", "winter_efficiency_pct": 89.3, "summer_efficiency_pct": 81.9, "comparative_hot_water_efficiency_pct": 57.6, "output_kw_max": 20.0, "final_year_of_manufacture": null, "raw": ["018573", "000047", "0", "2019/Jan/18 10:25", "Firebird Heating Solutions Ltd", "Firebird", "Envirogreen Combi HE Condensing Boiler", "20kW", "", "2018", "current", "4", "1", "1", "2", "0", "", "", "2", "2", "1", "20.0", "20.0", "", "", "89.3", "81.9", "", "57.6", "", "2", "", "", "202", "1", "1", "155", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "", "", "0003", "", "", "", "", "", "", "", "", "92.8", "97.4", "", "", "", "", "96.5"]} -{"pcdb_id": 18574, "brand_name": "Firebird", "model_name": "Envirogreen Combi HE Condensing Boiler", "model_qualifier": "26kW", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 81.7, "comparative_hot_water_efficiency_pct": 57.5, "output_kw_max": 26.0, "final_year_of_manufacture": null, "raw": ["018574", "000047", "0", "2019/Jan/18 10:25", "Firebird Heating Solutions Ltd", "Firebird", "Envirogreen Combi HE Condensing Boiler", "26kW", "", "2018", "current", "4", "1", "1", "2", "0", "", "", "2", "2", "1", "26.0", "26.0", "", "", "89.1", "81.7", "", "57.5", "", "2", "", "", "202", "1", "1", "143", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "92.7", "96.9", "", "", "", "", "96.1"]} -{"pcdb_id": 18575, "brand_name": "Firebird", "model_name": "Envirogreen Combi HE Condensing Boiler", "model_qualifier": "35kW", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 81.3, "comparative_hot_water_efficiency_pct": 57.2, "output_kw_max": 35.0, "final_year_of_manufacture": null, "raw": ["018575", "000047", "0", "2019/Jan/18 10:24", "Firebird Heating Solutions Ltd", "Firebird", "Envirogreen Combi HE Condensing Boiler", "35kW", "", "2018", "current", "4", "1", "1", "2", "0", "", "", "2", "2", "1", "35.0", "35.0", "", "", "88.7", "81.3", "", "57.2", "", "2", "", "", "202", "1", "1", "138", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "92.5", "95.9", "", "", "", "", "95.2"]} -{"pcdb_id": 18576, "brand_name": "Firebird", "model_name": "Envirogreen Combipac HE", "model_qualifier": "20kW", "winter_efficiency_pct": 89.3, "summer_efficiency_pct": 81.9, "comparative_hot_water_efficiency_pct": 57.6, "output_kw_max": 20.0, "final_year_of_manufacture": null, "raw": ["018576", "000047", "0", "2019/Jan/18 10:24", "Firebird Heating Solutions Ltd", "Firebird", "Envirogreen Combipac HE", "20kW", "", "2018", "current", "4", "1", "1", "2", "0", "", "", "2", "2", "1", "20.0", "20.0", "", "", "89.3", "81.9", "", "57.6", "", "2", "", "", "202", "1", "1", "155", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "92.8", "97.4", "", "", "", "", "96.5"]} -{"pcdb_id": 18577, "brand_name": "Firebird", "model_name": "Envirogreen Combipac HE", "model_qualifier": "26kW", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 81.7, "comparative_hot_water_efficiency_pct": 57.5, "output_kw_max": 26.0, "final_year_of_manufacture": null, "raw": ["018577", "000047", "0", "2019/Jan/18 10:24", "Firebird Heating Solutions Ltd", "Firebird", "Envirogreen Combipac HE", "26kW", "", "2018", "current", "4", "1", "1", "2", "0", "", "", "2", "2", "1", "26.0", "26.0", "", "", "89.1", "81.7", "", "57.5", "", "2", "", "", "202", "1", "1", "143", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "92.7", "96.9", "", "", "", "", "96.1"]} -{"pcdb_id": 18578, "brand_name": "Firebird", "model_name": "Envirogreen Combipac HE", "model_qualifier": "35kW", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 81.3, "comparative_hot_water_efficiency_pct": 57.2, "output_kw_max": 35.0, "final_year_of_manufacture": null, "raw": ["018578", "000047", "0", "2019/Jan/18 10:24", "Firebird Heating Solutions Ltd", "Firebird", "Envirogreen Combipac HE", "35kW", "", "2018", "current", "4", "1", "1", "2", "0", "", "", "2", "2", "1", "35.0", "35.0", "", "", "88.7", "81.3", "", "57.2", "", "2", "", "", "202", "1", "1", "138", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "92.5", "95.9", "", "", "", "", "95.2"]} -{"pcdb_id": 18579, "brand_name": "Potterton", "model_name": "ASSURE", "model_qualifier": "12 SYSTEM", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 12.0, "final_year_of_manufacture": null, "raw": ["018579", "000005", "0", "2019/Aug/09 14:26", "Baxi Heating UK", "Potterton", "ASSURE", "12 SYSTEM", "41-594-12", "2018", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "12.0", "12.0", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "20", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "88.2", "97.8", "", "", "", "", "96.0"]} -{"pcdb_id": 18580, "brand_name": "Potterton", "model_name": "ASSURE", "model_qualifier": "24 SYSTEM", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 24.0, "final_year_of_manufacture": null, "raw": ["018580", "000005", "0", "2019/Aug/09 14:34", "Baxi Heating UK", "Potterton", "ASSURE", "24 SYSTEM", "41-594-13", "2018", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24.0", "24.0", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "60", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "88.0", "97.8", "", "", "", "", "95.9"]} -{"pcdb_id": 18581, "brand_name": "Potterton", "model_name": "ASSURE", "model_qualifier": "18 SYSTEM LPG", "winter_efficiency_pct": 89.5, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 58.8, "output_kw_max": 18.0, "final_year_of_manufacture": null, "raw": ["018581", "000005", "0", "2019/Aug/09 14:36", "Baxi Heating UK", "Potterton", "ASSURE", "18 SYSTEM LPG", "41-592-96", "2018", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "18.0", "18.0", "", "", "89.5", "80.5", "", "58.8", "", "2", "1", "", "102", "1", "2", "30", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "90.2", "100.0", "", "", "", "", "98.1"]} -{"pcdb_id": 18582, "brand_name": "Potterton", "model_name": "ASSURE", "model_qualifier": "24 SYSTEM LPG", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 80.4, "comparative_hot_water_efficiency_pct": 58.7, "output_kw_max": 24.0, "final_year_of_manufacture": null, "raw": ["018582", "000005", "0", "2019/Aug/09 14:39", "Baxi Heating UK", "Potterton", "ASSURE", "24 SYSTEM LPG", "41-594-16", "2018", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "24.0", "24.0", "", "", "89.4", "80.4", "", "58.7", "", "2", "1", "", "102", "1", "2", "60", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "90.0", "99.9", "", "", "", "", "98.0"]} -{"pcdb_id": 18583, "brand_name": "Baxi", "model_name": "615 SYSTEM", "model_qualifier": "15", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 15.0, "final_year_of_manufacture": null, "raw": ["018583", "000005", "0", "2019/Aug/09 14:03", "Baxi Heating UK", "Baxi", "615 SYSTEM", "15", "41-470-56", "2018", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "15.0", "15.0", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "25", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "88.2", "97.8", "", "", "", "", "95.9"]} -{"pcdb_id": 18584, "brand_name": "Baxi", "model_name": "618 SYSTEM", "model_qualifier": "18", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 18.0, "final_year_of_manufacture": null, "raw": ["018584", "000005", "0", "2019/Aug/09 14:13", "Baxi Heating UK", "Baxi", "618 SYSTEM", "18", "41-470-57", "2018", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18.0", "18.0", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "30", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "88.2", "97.8", "", "", "", "", "96.0"]} -{"pcdb_id": 18585, "brand_name": "Baxi", "model_name": "624 SYSTEM", "model_qualifier": "24", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 24.0, "final_year_of_manufacture": null, "raw": ["018585", "000005", "0", "2019/Aug/09 14:15", "Baxi Heating UK", "Baxi", "624 SYSTEM", "24", "41-470-59", "2018", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24.0", "24.0", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "60", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "88.0", "97.8", "", "", "", "", "95.9"]} -{"pcdb_id": 18586, "brand_name": "Baxi", "model_name": "624 SYSTEM", "model_qualifier": "24 LPG", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 80.4, "comparative_hot_water_efficiency_pct": 58.7, "output_kw_max": 24.0, "final_year_of_manufacture": null, "raw": ["018586", "000005", "0", "2019/Aug/09 14:20", "Baxi Heating UK", "Baxi", "624 SYSTEM", "24 LPG", "41-470-64", "2018", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "24.0", "24.0", "", "", "89.4", "80.4", "", "58.7", "", "2", "1", "", "102", "1", "2", "60", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "90.0", "99.9", "", "", "", "", "98.0"]} -{"pcdb_id": 18587, "brand_name": "Intergas", "model_name": "Xclusive 24", "model_qualifier": "", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 86.6, "comparative_hot_water_efficiency_pct": 73.3, "output_kw_max": 18.2, "final_year_of_manufacture": null, "raw": ["018587", "000256", "0", "2020/Jan/22 13:09", "Intergas Heating Ltd", "Intergas", "Xclusive 24", "", "47-291-13", "2018", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "18.2", "18.2", "", "", "88.2", "86.6", "", "73.3", "", "2", "", "", "104", "1", "2", "100", "2", "0", "", "", "", "0", "", "", "", "", "1", "7.1823", "0.0437", "0.0", "1.05872", "", "", "", "", "", "", "", "", "0015", "", "", "", "", "", "", "", "", "87.8", "97.4", "", "", "", "", "95.6"]} -{"pcdb_id": 18588, "brand_name": "Intergas", "model_name": "Xclusive 30", "model_qualifier": "", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 86.7, "comparative_hot_water_efficiency_pct": 73.8, "output_kw_max": 23.7, "final_year_of_manufacture": null, "raw": ["018588", "000256", "0", "2020/Jan/22 13:09", "Intergas Heating Ltd", "Intergas", "Xclusive 30", "", "47-291-14", "2018", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "23.7", "23.7", "", "", "88.2", "86.7", "", "73.8", "", "2", "", "", "104", "1", "2", "100", "2", "0", "", "", "", "0", "", "", "", "", "1", "7.1322", "0.039", "0.0", "1.01523", "", "", "", "", "", "", "", "", "0015", "", "", "", "", "", "", "", "", "87.9", "97.2", "", "", "", "", "95.5"]} -{"pcdb_id": 18589, "brand_name": "Intergas", "model_name": "Xclusive 36", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 87.0, "comparative_hot_water_efficiency_pct": 76.7, "output_kw_max": 27.0, "final_year_of_manufacture": null, "raw": ["018589", "000256", "0", "2020/Jan/22 13:09", "Intergas Heating Ltd", "Intergas", "Xclusive 36", "", "47-291-15", "2018", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "27.0", "27.0", "", "", "88.5", "87.0", "", "76.7", "", "2", "", "", "104", "1", "2", "100", "2", "0", "", "", "", "0", "", "", "", "", "1", "6.8687", "0.0371", "0.0", "0.78648", "", "", "", "", "", "", "", "", "0015", "", "", "", "", "", "", "", "", "88.9", "97.6", "", "", "", "", "95.9"]} -{"pcdb_id": 18590, "brand_name": "Intergas", "model_name": "Xtreme 24", "model_qualifier": "", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 86.6, "comparative_hot_water_efficiency_pct": 82.8, "output_kw_max": 18.7, "final_year_of_manufacture": null, "raw": ["018590", "000256", "0", "2020/Jan/22 13:09", "Intergas Heating Ltd", "Intergas", "Xtreme 24", "", "47-291-10", "2018", "current", "1", "2", "1", "2", "1", "", "", "2", "2", "2", "18.7", "18.7", "", "", "88.2", "86.6", "", "82.8", "", "2", "", "", "104", "1", "2", "100", "2", "0", "", "", "", "0", "", "", "", "", "1", "6.357", "0.039", "0.0005", "0.26225", "", "", "", "", "", "", "", "", "0015", "", "", "", "", "", "", "", "", "87.8", "97.4", "", "", "", "", "95.6"]} -{"pcdb_id": 18591, "brand_name": "Intergas", "model_name": "Xtreme 30", "model_qualifier": "", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 86.7, "comparative_hot_water_efficiency_pct": 82.0, "output_kw_max": 23.7, "final_year_of_manufacture": null, "raw": ["018591", "000256", "0", "2020/Jan/22 13:09", "Intergas Heating Ltd", "Intergas", "Xtreme 30", "", "47-291-11", "2018", "current", "1", "2", "1", "2", "1", "", "", "2", "2", "2", "23.7", "23.7", "", "", "88.2", "86.7", "", "82.0", "", "2", "", "", "104", "1", "2", "100", "2", "0", "", "", "", "0", "", "", "", "", "1", "6.421", "0.0385", "0.0", "0.33115", "", "", "", "", "", "", "", "", "0015", "", "", "", "", "", "", "", "", "87.9", "97.2", "", "", "", "", "95.5"]} -{"pcdb_id": 18592, "brand_name": "Intergas", "model_name": "Xtreme 36", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 87.0, "comparative_hot_water_efficiency_pct": 82.1, "output_kw_max": 27.0, "final_year_of_manufacture": null, "raw": ["018592", "000256", "0", "2020/Jan/22 13:09", "Intergas Heating Ltd", "Intergas", "Xtreme 36", "", "47-291-12", "2018", "current", "1", "2", "1", "2", "1", "", "", "2", "2", "2", "27.0", "27.0", "", "", "88.5", "87.0", "", "82.1", "", "2", "", "", "104", "1", "2", "100", "2", "0", "", "", "", "0", "", "", "", "", "1", "6.415", "0.037", "0.0", "0.34845", "", "", "", "", "", "", "", "", "0015", "", "", "", "", "", "", "", "", "88.9", "97.6", "", "", "", "", "95.9"]} -{"pcdb_id": 18593, "brand_name": "Glow-worm", "model_name": "Energy2 30c", "model_qualifier": "-A (P-GB)", "winter_efficiency_pct": 90.4, "summer_efficiency_pct": 81.8, "comparative_hot_water_efficiency_pct": 57.5, "output_kw_max": 30.6, "final_year_of_manufacture": null, "raw": ["018593", "000207", "0", "2019/May/01 15:21", "Glow-worm", "Glow-worm", "Energy2 30c", "-A (P-GB)", "47-019-38", "2018", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "1", "30.6", "30.6", "", "", "90.4", "81.8", "", "57.5", "", "2", "0", "", "104", "1", "2", "31", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0085", "", "", "", "", "", "", "", "", "90.7", "99.7", "", "", "", "", "98.0"]} -{"pcdb_id": 18598, "brand_name": "Daikin", "model_name": "EHY2KOMB28AA", "model_qualifier": "", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 86.7, "comparative_hot_water_efficiency_pct": 72.3, "output_kw_max": 23.1, "final_year_of_manufacture": null, "raw": ["018598", "000278", "0", "2020/Jan/22 13:09", "Daikin Europe NV", "Daikin", "EHY2KOMB28AA", "", "", "2019", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "23.1", "23.1", "", "", "88.2", "86.7", "", "72.3", "", "2", "", "", "104", "1", "2", "45", "2", "0", "", "", "", "0", "", "", "", "", "1", "7.281", "0.138", "0.0094", "1.1037", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "97.2", "", "", "", "", "95.5"]} -{"pcdb_id": 18599, "brand_name": "Daikin", "model_name": "EHY2KOMB32AA", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 87.0, "comparative_hot_water_efficiency_pct": 74.4, "output_kw_max": 26.2, "final_year_of_manufacture": null, "raw": ["018599", "000278", "0", "2020/Jan/22 13:10", "Daikin Europe NV", "Daikin", "EHY2KOMB32AA", "", "", "2019", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "26.2", "26.2", "", "", "88.5", "87.0", "", "74.4", "", "2", "", "", "104", "1", "2", "45", "2", "0", "", "", "", "0", "", "", "", "", "1", "7.079", "0.05", "0.0009", "0.98426", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.9", "97.6", "", "", "", "", "95.9"]} -{"pcdb_id": 18600, "brand_name": "Firebird", "model_name": "Envirogreen Kitchen Condensing Boiler", "model_qualifier": "12-18kW", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 59.1, "output_kw_max": 18.0, "final_year_of_manufacture": null, "raw": ["018600", "000047", "0", "2019/Oct/21 15:46", "Firebird Heating Solutions Ltd", "Firebird", "Envirogreen Kitchen Condensing Boiler", "12-18kW", "", "2018", "current", "4", "1", "1", "1", "0", "", "", "2", "2", "1", "12.0", "18.0", "", "", "88.8", "81.0", "", "59.1", "", "2", "", "", "201", "1", "1", "187", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "92.2", "96.1", "", "", "", "", "95.4"]} -{"pcdb_id": 18601, "brand_name": "Firebird", "model_name": "Envirogreen Heatpac Condensing Boiler", "model_qualifier": "12-18kW", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 59.1, "output_kw_max": 18.0, "final_year_of_manufacture": null, "raw": ["018601", "000047", "0", "2019/Jul/08 15:16", "Firebird Heating Solutions Ltd", "Firebird", "Envirogreen Heatpac Condensing Boiler", "12-18kW", "", "2018", "current", "4", "1", "2", "1", "0", "", "", "2", "2", "1", "12.0", "18.0", "", "", "88.8", "81.0", "", "59.1", "", "2", "", "", "201", "1", "1", "187", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "92.2", "96.1", "", "", "", "", "95.4"]} -{"pcdb_id": 18602, "brand_name": "Firebird", "model_name": "Envirogreen Popular Condensing Boiler", "model_qualifier": "12-18kW", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 59.1, "output_kw_max": 18.0, "final_year_of_manufacture": null, "raw": ["018602", "000047", "0", "2019/Jul/08 15:16", "Firebird Heating Solutions Ltd", "Firebird", "Envirogreen Popular Condensing Boiler", "12-18kW", "", "2018", "current", "4", "1", "1", "1", "0", "", "", "2", "2", "1", "12.0", "18.0", "", "", "88.8", "81.0", "", "59.1", "", "2", "", "", "201", "1", "1", "187", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "92.2", "96.1", "", "", "", "", "95.4"]} -{"pcdb_id": 18603, "brand_name": "Firebird", "model_name": "Envirogreen Slimline Heatpac Condensing Boiler", "model_qualifier": "12-18kW", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 59.1, "output_kw_max": 18.0, "final_year_of_manufacture": null, "raw": ["018603", "000047", "0", "2019/Oct/21 15:46", "Firebird Heating Solutions Ltd", "Firebird", "Envirogreen Slimline Heatpac Condensing Boiler", "12-18kW", "", "2018", "current", "4", "1", "2", "1", "0", "", "", "2", "2", "1", "12.0", "18.0", "", "", "88.8", "81.0", "", "59.1", "", "2", "", "", "201", "1", "1", "187", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "92.2", "96.1", "", "", "", "", "95.4"]} -{"pcdb_id": 18604, "brand_name": "Firebird", "model_name": "Envirogreen Kitchen", "model_qualifier": "36-44kW", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 81.2, "comparative_hot_water_efficiency_pct": 59.3, "output_kw_max": 44.0, "final_year_of_manufacture": null, "raw": ["018604", "000047", "0", "2019/Oct/21 15:46", "Firebird Heating Solutions Ltd", "Firebird", "Envirogreen Kitchen", "36-44kW", "", "2018", "current", "4", "1", "1", "1", "0", "", "", "2", "2", "1", "36.0", "44.0", "", "", "89.0", "81.2", "", "59.3", "", "2", "", "", "201", "1", "1", "160", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "92.6", "96.7", "", "", "", "", "95.9"]} -{"pcdb_id": 18605, "brand_name": "Firebird", "model_name": "Envirogreen Popular", "model_qualifier": "36-44kW", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 81.2, "comparative_hot_water_efficiency_pct": 59.3, "output_kw_max": 44.0, "final_year_of_manufacture": null, "raw": ["018605", "000047", "0", "2019/Oct/21 15:46", "Firebird Heating Solutions Ltd", "Firebird", "Envirogreen Popular", "36-44kW", "", "2018", "current", "4", "1", "1", "1", "0", "", "", "2", "2", "1", "36.0", "44.0", "", "", "89.0", "81.2", "", "59.3", "", "2", "", "", "201", "1", "1", "160", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "92.6", "96.7", "", "", "", "", "95.9"]} -{"pcdb_id": 18606, "brand_name": "Firebird", "model_name": "Envirogreen System", "model_qualifier": "36-44kW", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 81.2, "comparative_hot_water_efficiency_pct": 59.3, "output_kw_max": 44.0, "final_year_of_manufacture": null, "raw": ["018606", "000047", "0", "2019/Oct/21 15:46", "Firebird Heating Solutions Ltd", "Firebird", "Envirogreen System", "36-44kW", "", "2018", "current", "4", "1", "1", "1", "0", "", "", "2", "2", "1", "36.0", "44.0", "", "", "89.0", "81.2", "", "59.3", "", "2", "", "", "201", "1", "1", "160", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "92.6", "96.7", "", "", "", "", "95.9"]} -{"pcdb_id": 18607, "brand_name": "Firebird", "model_name": "Envirogreen Systempac", "model_qualifier": "36-44kW", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 81.2, "comparative_hot_water_efficiency_pct": 59.3, "output_kw_max": 44.0, "final_year_of_manufacture": null, "raw": ["018607", "000047", "0", "2019/Oct/21 15:47", "Firebird Heating Solutions Ltd", "Firebird", "Envirogreen Systempac", "36-44kW", "", "2018", "current", "4", "1", "2", "1", "0", "", "", "2", "2", "1", "36.0", "44.0", "", "", "89.0", "81.2", "", "59.3", "", "2", "", "", "201", "1", "1", "160", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "92.6", "96.7", "", "", "", "", "95.9"]} -{"pcdb_id": 18608, "brand_name": "Firebird", "model_name": "Envirogreen Heatpac", "model_qualifier": "36-44kW", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 81.2, "comparative_hot_water_efficiency_pct": 59.3, "output_kw_max": 44.0, "final_year_of_manufacture": null, "raw": ["018608", "000047", "0", "2019/Oct/21 15:47", "Firebird Heating Solutions Ltd", "Firebird", "Envirogreen Heatpac", "36-44kW", "", "2018", "current", "4", "1", "2", "1", "0", "", "", "2", "2", "1", "36.0", "44.0", "", "", "89.0", "81.2", "", "59.3", "", "2", "", "", "201", "1", "1", "160", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "92.6", "96.7", "", "", "", "", "95.9"]} -{"pcdb_id": 18609, "brand_name": "Biasi", "model_name": "ADVANCE 15OV", "model_qualifier": "41-583-35", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 78.9, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 16.5, "final_year_of_manufacture": null, "raw": ["018609", "000208", "0", "2019/Jun/12 12:00", "Biasi (UK)", "Biasi", "ADVANCE 15OV", "41-583-35", "", "2019", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "16.5", "16.5", "", "", "87.9", "78.9", "", "57.7", "", "2", "", "", "102", "1", "2", "24", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.3", "96.9", "", "", "", "", "95.1"]} -{"pcdb_id": 18610, "brand_name": "Biasi", "model_name": "ADVANCE 18OV", "model_qualifier": "41-583-36", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 78.9, "comparative_hot_water_efficiency_pct": 57.6, "output_kw_max": 20.3, "final_year_of_manufacture": null, "raw": ["018610", "000208", "0", "2019/Jun/12 12:01", "Biasi (UK)", "Biasi", "ADVANCE 18OV", "41-583-36", "", "2019", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "20.3", "20.3", "", "", "87.9", "78.9", "", "57.6", "", "2", "", "", "102", "1", "2", "36", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.0", "96.9", "", "", "", "", "95.1"]} -{"pcdb_id": 18611, "brand_name": "Biasi", "model_name": "ADVANCE 24OV", "model_qualifier": "41-583-37", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 24.4, "final_year_of_manufacture": null, "raw": ["018611", "000208", "0", "2019/Jun/12 12:02", "Biasi (UK)", "Biasi", "ADVANCE 24OV", "41-583-37", "", "2019", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24.4", "24.4", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "40", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "96.8", "", "", "", "", "95.1"]} -{"pcdb_id": 18612, "brand_name": "Firebird", "model_name": "Envirogreen Heatpac Condensing Boiler", "model_qualifier": "58kW", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 80.6, "comparative_hot_water_efficiency_pct": 58.9, "output_kw_max": 58.0, "final_year_of_manufacture": null, "raw": ["018612", "000047", "0", "2019/Oct/21 15:47", "Firebird Heating Solutions Ltd", "Firebird", "Envirogreen Heatpac Condensing Boiler", "58kW", "", "2019", "current", "4", "1", "2", "1", "0", "", "", "2", "2", "1", "58.0", "58.0", "", "", "88.4", "80.6", "", "58.9", "", "2", "", "", "201", "1", "1", "166", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.2", "95.8", "", "", "", "", "94.9"]} -{"pcdb_id": 18613, "brand_name": "Firebird", "model_name": "Envirogreen Kitchen Condensing Boiler", "model_qualifier": "58kW", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 80.6, "comparative_hot_water_efficiency_pct": 58.9, "output_kw_max": 58.0, "final_year_of_manufacture": null, "raw": ["018613", "000047", "0", "2019/Oct/21 15:47", "Firebird Heating Solutions Ltd", "Firebird", "Envirogreen Kitchen Condensing Boiler", "58kW", "", "2019", "current", "4", "1", "1", "1", "0", "", "", "2", "2", "1", "58.0", "58.0", "", "", "88.4", "80.6", "", "58.9", "", "2", "", "", "201", "1", "1", "166", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.2", "95.8", "", "", "", "", "94.9"]} -{"pcdb_id": 18614, "brand_name": "Firebird", "model_name": "Envirogreen Popular Condensing Boiler", "model_qualifier": "58kW", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 80.6, "comparative_hot_water_efficiency_pct": 58.9, "output_kw_max": 58.0, "final_year_of_manufacture": null, "raw": ["018614", "000047", "0", "2019/Oct/21 15:48", "Firebird Heating Solutions Ltd", "Firebird", "Envirogreen Popular Condensing Boiler", "58kW", "", "2019", "current", "4", "1", "1", "1", "0", "", "", "2", "2", "1", "58.0", "58.0", "", "", "88.4", "80.6", "", "58.9", "", "2", "", "", "201", "1", "1", "166", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.2", "95.8", "", "", "", "", "94.9"]} -{"pcdb_id": 18615, "brand_name": "Ariston", "model_name": "CLAS ONE R 24", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 21.5, "final_year_of_manufacture": null, "raw": ["018615", "000080", "0", "2020/Sep/08 16:36", "Ariston Thermo S.p.A", "Ariston", "CLAS ONE R 24", "", "3301466", "2019", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "21.5", "21.5", "", "", "88.8", "79.8", "", "58.3", "", "2", "", "", "102", "1", "2", "30", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "98.9", "", "", "", "", "96.8"]} -{"pcdb_id": 18616, "brand_name": "Worcester", "model_name": "Greenstar 8000 Life", "model_qualifier": "GR8300iW 30 C NG", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 88.2, "comparative_hot_water_efficiency_pct": 73.5, "output_kw_max": 29.5, "final_year_of_manufacture": null, "raw": ["018616", "000035", "0", "2020/Jul/27 17:33", "Bosch Thermotechnology", "Worcester", "Greenstar 8000 Life", "GR8300iW 30 C NG", "47-800-18", "2018", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "29.5", "29.5", "", "", "88.8", "88.2", "", "73.5", "", "2", "", "", "104", "1", "2", "67", "1", "0", "", "", "", "0", "", "", "", "", "2", "7.168", "0.098", "0.001", "1.05319", "13.007", "0.118", "0.001", "1.02566", "0.0", "", "", "", "8325", "", "", "", "", "", "", "", "", "88.3", "98.7", "", "", "", "", "96.7"]} -{"pcdb_id": 18617, "brand_name": "Worcester", "model_name": "Greenstar 8000 Life", "model_qualifier": "GR8300iW 30 R NG", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 29.5, "final_year_of_manufacture": null, "raw": ["018617", "000035", "0", "2019/Aug/22 14:16", "Bosch Thermotechnology", "Worcester", "Greenstar 8000 Life", "GR8300iW 30 R NG", "41-406-98", "2018", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "29.5", "29.5", "", "", "88.8", "79.8", "", "58.3", "", "2", "", "", "102", "1", "2", "67", "1", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0305", "", "", "", "", "", "", "", "", "88.3", "98.7", "", "", "", "", "96.7"]} -{"pcdb_id": 18618, "brand_name": "Worcester", "model_name": "Greenstar 8000 Life", "model_qualifier": "GR8300iW 30 S NG", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 29.5, "final_year_of_manufacture": null, "raw": ["018618", "000035", "0", "2019/Aug/22 14:18", "Bosch Thermotechnology", "Worcester", "Greenstar 8000 Life", "GR8300iW 30 S NG", "41-406-91", "2018", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "29.5", "29.5", "", "", "88.8", "79.8", "", "58.3", "", "2", "", "", "102", "1", "2", "67", "1", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "8325", "", "", "", "", "", "", "", "", "88.3", "98.7", "", "", "", "", "96.7"]} -{"pcdb_id": 18619, "brand_name": "Worcester", "model_name": "Greenstar 8000 Life", "model_qualifier": "GR8300iW 35 C NG", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 88.2, "comparative_hot_water_efficiency_pct": 75.1, "output_kw_max": 33.7, "final_year_of_manufacture": null, "raw": ["018619", "000035", "0", "2020/Jul/27 17:39", "Bosch Thermotechnology", "Worcester", "Greenstar 8000 Life", "GR8300iW 35 C NG", "47-800-17", "2018", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "33.7", "33.7", "", "", "88.6", "88.2", "", "75.1", "", "2", "", "", "104", "1", "2", "48", "1", "0", "", "", "", "0", "", "", "", "", "2", "7.012", "0.103", "0.0045", "0.84809", "12.813", "0.118", "0.0005", "0.85555", "0.00004", "", "", "", "8325", "", "", "", "", "", "", "", "", "86.9", "98.8", "", "", "", "", "96.6"]} -{"pcdb_id": 18620, "brand_name": "Worcester", "model_name": "Greenstar 8000 Life", "model_qualifier": "GR8300iW 35 R NG", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 33.7, "final_year_of_manufacture": null, "raw": ["018620", "000035", "0", "2019/Aug/22 14:19", "Bosch Thermotechnology", "Worcester", "Greenstar 8000 Life", "GR8300iW 35 R NG", "41-406-97", "2018", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "33.7", "33.7", "", "", "88.6", "79.6", "", "58.2", "", "2", "", "", "102", "1", "2", "48", "1", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0305", "", "", "", "", "", "", "", "", "86.9", "98.8", "", "", "", "", "96.6"]} -{"pcdb_id": 18621, "brand_name": "Worcester", "model_name": "Greenstar 8000 Life", "model_qualifier": "GR8300iW 35 S NG", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 33.7, "final_year_of_manufacture": null, "raw": ["018621", "000035", "0", "2019/Aug/21 17:19", "Bosch Thermotechnology", "Worcester", "Greenstar 8000 Life", "GR8300iW 35 S NG", "41-406-90", "2018", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "33.7", "33.7", "", "", "88.6", "79.6", "", "58.2", "", "2", "", "", "102", "1", "2", "48", "1", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "8325", "", "", "", "", "", "", "", "", "86.9", "98.8", "", "", "", "", "96.6"]} -{"pcdb_id": 18622, "brand_name": "Worcester", "model_name": "Greenstar 8000 Life", "model_qualifier": "GR8300iW 40 C NG", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 88.2, "comparative_hot_water_efficiency_pct": 73.4, "output_kw_max": 33.7, "final_year_of_manufacture": null, "raw": ["018622", "000035", "0", "2020/Jul/27 17:46", "Bosch Thermotechnology", "Worcester", "Greenstar 8000 Life", "GR8300iW 40 C NG", "47-800-16", "2018", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "33.7", "33.7", "", "", "88.7", "88.2", "", "73.4", "", "2", "", "", "104", "1", "2", "48", "1", "0", "", "", "", "0", "", "", "", "", "2", "7.175", "0.107", "0.001", "1.03647", "13.05", "0.126", "0.0005", "1.03238", "0.00001", "", "", "", "8325", "", "", "", "", "", "", "", "", "87.4", "98.7", "", "", "", "", "96.6"]} -{"pcdb_id": 18623, "brand_name": "Worcester", "model_name": "Greenstar 8000 Life", "model_qualifier": "GR8300iW 40 R NG", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 40.0, "final_year_of_manufacture": null, "raw": ["018623", "000035", "0", "2019/Oct/10 16:30", "Bosch Thermotechnology", "Worcester", "Greenstar 8000 Life", "GR8300iW 40 R NG", "41-406-96", "2018", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "40", "40", "", "", "88.7", "79.7", "", "58.2", "", "2", "", "", "102", "1", "2", "75", "1", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0305", "", "", "", "", "", "", "", "", "87.4", "98.7", "", "", "", "", "96.6"]} -{"pcdb_id": 18624, "brand_name": "Worcester", "model_name": "Greenstar 8000 Life", "model_qualifier": "GR8300IW 45 C NG", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 88.2, "comparative_hot_water_efficiency_pct": 74.1, "output_kw_max": 33.7, "final_year_of_manufacture": null, "raw": ["018624", "000035", "0", "2020/Jul/27 17:54", "Bosch Thermotechnology", "Worcester", "Greenstar 8000 Life", "GR8300IW 45 C NG", "47-800-15", "2018", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "33.7", "33.7", "", "", "88.9", "88.2", "", "74.1", "", "2", "", "", "104", "1", "2", "48", "1", "0", "", "", "", "0", "", "", "", "", "2", "7.103", "0.104", "0.0075", "0.96653", "12.953", "0.121", "0.0035", "0.92531", "0.00004", "", "", "", "8325", "", "", "", "", "", "", "", "", "88.8", "98.8", "", "", "", "", "96.9"]} -{"pcdb_id": 18625, "brand_name": "Worcester", "model_name": "Greenstar 8000 Life", "model_qualifier": "GR8300iW 45 R NG", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 42.6, "final_year_of_manufacture": null, "raw": ["018625", "000035", "0", "2020/Jan/15 14:16", "Bosch Thermotechnology", "Worcester", "Greenstar 8000 Life", "GR8300iW 45 R NG", "41-406-95", "2018", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "42.6", "42.6", "", "", "89.2", "80.2", "", "58.6", "", "2", "", "", "102", "1", "2", "84", "1", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0305", "", "", "", "", "", "", "", "", "88.8", "99.5", "", "", "", "", "97.5"]} -{"pcdb_id": 18626, "brand_name": "Worcester", "model_name": "Greenstar 8000 Life", "model_qualifier": "GR8300iW 50 C NG", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 88.2, "comparative_hot_water_efficiency_pct": 74.2, "output_kw_max": 33.7, "final_year_of_manufacture": null, "raw": ["018626", "000035", "0", "2020/Jul/27 17:56", "Bosch Thermotechnology", "Worcester", "Greenstar 8000 Life", "GR8300iW 50 C NG", "47-800-14", "2018", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "33.7", "33.7", "", "", "88.9", "88.2", "", "74.2", "", "2", "", "", "104", "1", "2", "48", "1", "0", "", "", "", "0", "", "", "", "", "2", "7.098", "0.101", "0.001", "0.9997", "12.909", "0.121", "0.001", "0.95851", "0.0", "", "", "", "8325", "", "", "", "", "", "", "", "", "88.8", "98.8", "", "", "", "", "96.9"]} -{"pcdb_id": 18627, "brand_name": "Worcester", "model_name": "Greenstar 8000 Life", "model_qualifier": "GR8300iW 50 R NG", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 47.9, "final_year_of_manufacture": null, "raw": ["018627", "000035", "0", "2020/Jan/15 14:16", "Bosch Thermotechnology", "Worcester", "Greenstar 8000 Life", "GR8300iW 50 R NG", "41-406-94", "2018", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "47.9", "47.9", "", "", "89.0", "80.0", "", "58.5", "", "2", "", "", "102", "1", "2", "84", "1", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0305", "", "", "", "", "", "", "", "", "88.6", "99.2", "", "", "", "", "97.2"]} -{"pcdb_id": 18628, "brand_name": "BoilerPlan", "model_name": "BP31 HE", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 55.9, "output_kw_max": 24.3, "final_year_of_manufacture": null, "raw": ["018628", "000313", "0", "2020/Jun/24 10:37", "Boiler Plan (UK) Ltd", "BoilerPlan", "BP31 HE", "", "", "2019", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.3", "24.3", "", "", "88.0", "79.4", "", "55.9", "", "2", "", "", "104", "1", "2", "36", "5", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0015", "", "", "", "", "", "", "", "", "87.5", "97.1", "", "", "", "", "95.3"]} -{"pcdb_id": 18629, "brand_name": "E.C.A.", "model_name": "PROTEUS PREMIX", "model_qualifier": "24 HCH NG ERP UK", "winter_efficiency_pct": 87.7, "summer_efficiency_pct": 78.7, "comparative_hot_water_efficiency_pct": 57.5, "output_kw_max": 24.5, "final_year_of_manufacture": null, "raw": ["018629", "000248", "0", "2020/Feb/18 11:24", "Emas Makina Sanayi", "E.C.A.", "PROTEUS PREMIX", "24 HCH NG ERP UK", "41-814-01", "2017", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24.5", "24.5", "", "", "87.7", "78.7", "", "57.5", "", "2", "", "", "102", "1", "2", "40", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "96.0", "", "", "", "", "94.5"]} -{"pcdb_id": 18630, "brand_name": "E.C.A.", "model_name": "PROTEUS PREMIX", "model_qualifier": "24 HM NG ERP UK", "winter_efficiency_pct": 87.7, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 55.6, "output_kw_max": 24.5, "final_year_of_manufacture": null, "raw": ["018630", "000248", "0", "2020/Feb/18 11:25", "Emas Makina Sanayi", "E.C.A.", "PROTEUS PREMIX", "24 HM NG ERP UK", "47-814-01", "2017", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.5", "24.5", "", "", "87.7", "79.1", "", "55.6", "", "2", "", "", "104", "1", "2", "40", "5", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "96.0", "", "", "", "", "94.5"]} -{"pcdb_id": 18631, "brand_name": "E.C.A.", "model_name": "PROTEUS PREMIX", "model_qualifier": "24 HST NG ERP UK", "winter_efficiency_pct": 87.7, "summer_efficiency_pct": 78.7, "comparative_hot_water_efficiency_pct": 57.5, "output_kw_max": 24.5, "final_year_of_manufacture": null, "raw": ["018631", "000248", "0", "2020/Feb/18 11:25", "Emas Makina Sanayi", "E.C.A.", "PROTEUS PREMIX", "24 HST NG ERP UK", "41-814-05", "2018", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24.5", "24.5", "", "", "87.7", "78.7", "", "57.5", "", "2", "", "", "102", "1", "2", "40", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "96.0", "", "", "", "", "94.5"]} -{"pcdb_id": 18632, "brand_name": "E.C.A.", "model_name": "PROTEUS PREMIX", "model_qualifier": "28 HCH NG ERP UK", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 28.0, "final_year_of_manufacture": null, "raw": ["018632", "000248", "0", "2020/Feb/18 11:25", "Emas Makina Sanayi", "E.C.A.", "PROTEUS PREMIX", "28 HCH NG ERP UK", "41-814-02", "2017", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "28.0", "28.0", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "51", "4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "96.9", "", "", "", "", "95.2"]} -{"pcdb_id": 18633, "brand_name": "E.C.A.", "model_name": "PROTEUS PREMIX", "model_qualifier": "28 HM NG ERP UK", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 55.9, "output_kw_max": 28.0, "final_year_of_manufacture": null, "raw": ["018633", "000248", "0", "2020/Feb/18 11:25", "Emas Makina Sanayi", "E.C.A.", "PROTEUS PREMIX", "28 HM NG ERP UK", "47-814-02", "2017", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28.0", "28.0", "", "", "88.0", "79.4", "", "55.9", "", "2", "", "", "104", "1", "2", "51", "4", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "96.9", "", "", "", "", "95.2"]} -{"pcdb_id": 18634, "brand_name": "E.C.A.", "model_name": "PROTEUS PREMIX", "model_qualifier": "28 HST NG ERP UK", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 28.0, "final_year_of_manufacture": null, "raw": ["018634", "000248", "0", "2020/Feb/18 11:26", "Emas Makina Sanayi", "E.C.A.", "PROTEUS PREMIX", "28 HST NG ERP UK", "41-814-06", "2017", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "28.0", "28.0", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "51", "4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "96.9", "", "", "", "", "95.2"]} -{"pcdb_id": 18635, "brand_name": "E.C.A.", "model_name": "PROTEUS PREMIX", "model_qualifier": "30 HCH NG ERP UK", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 30.0, "final_year_of_manufacture": null, "raw": ["018635", "000248", "0", "2020/Feb/18 11:26", "Emas Makina Sanayi", "E.C.A.", "PROTEUS PREMIX", "30 HCH NG ERP UK", "41-814-03", "2017", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "30.0", "30.0", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "56", "4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "96.8", "", "", "", "", "95.1"]} -{"pcdb_id": 18636, "brand_name": "E.C.A.", "model_name": "PROTEUS PREMIX", "model_qualifier": "30 HM NG ERP UK", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 55.8, "output_kw_max": 30.0, "final_year_of_manufacture": null, "raw": ["018636", "000248", "0", "2020/Feb/18 11:26", "Emas Makina Sanayi", "E.C.A.", "PROTEUS PREMIX", "30 HM NG ERP UK", "47-814-03", "2017", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "30.0", "30.0", "", "", "88.0", "79.4", "", "55.8", "", "2", "", "", "104", "1", "2", "56", "4", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "96.8", "", "", "", "", "95.1"]} -{"pcdb_id": 18637, "brand_name": "E.C.A.", "model_name": "PROTEUS PREMIX", "model_qualifier": "30 HST NG ERP UK", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 30.0, "final_year_of_manufacture": null, "raw": ["018637", "000248", "0", "2020/Feb/18 11:27", "Emas Makina Sanayi", "E.C.A.", "PROTEUS PREMIX", "30 HST NG ERP UK", "41-814-07", "2017", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "30.0", "30.0", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "56", "4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "96.8", "", "", "", "", "95.1"]} -{"pcdb_id": 18638, "brand_name": "E.C.A.", "model_name": "PROTEUS PREMIX", "model_qualifier": "35 HCH NG ERP UK", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 78.9, "comparative_hot_water_efficiency_pct": 57.6, "output_kw_max": 35.0, "final_year_of_manufacture": null, "raw": ["018638", "000248", "0", "2020/Feb/18 11:27", "Emas Makina Sanayi", "E.C.A.", "PROTEUS PREMIX", "35 HCH NG ERP UK", "41-814-04", "2017", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "35.0", "35.0", "", "", "87.9", "78.9", "", "57.6", "", "2", "", "", "102", "1", "2", "66", "4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "96.5", "", "", "", "", "94.9"]} -{"pcdb_id": 18639, "brand_name": "E.C.A.", "model_name": "PROTEUS PREMIX", "model_qualifier": "35 HM NG ERP UK", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 55.7, "output_kw_max": 35.0, "final_year_of_manufacture": null, "raw": ["018639", "000248", "0", "2020/Feb/18 11:27", "Emas Makina Sanayi", "E.C.A.", "PROTEUS PREMIX", "35 HM NG ERP UK", "47-814-04", "2017", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "35.0", "35.0", "", "", "87.9", "79.3", "", "55.7", "", "2", "", "", "104", "1", "2", "66", "4", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "96.5", "", "", "", "", "94.9"]} -{"pcdb_id": 18640, "brand_name": "E.C.A.", "model_name": "PROTEUS PREMIX", "model_qualifier": "35 HST NG ERP UK", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 78.9, "comparative_hot_water_efficiency_pct": 57.6, "output_kw_max": 35.0, "final_year_of_manufacture": null, "raw": ["018640", "000248", "0", "2020/Feb/18 11:28", "Emas Makina Sanayi", "E.C.A.", "PROTEUS PREMIX", "35 HST NG ERP UK", "41-814-08", "2017", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "35.0", "35.0", "", "", "87.9", "78.9", "", "57.6", "", "2", "", "", "102", "1", "2", "66", "4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "96.5", "", "", "", "", "94.9"]} -{"pcdb_id": 18641, "brand_name": "ATAG", "model_name": "I24S", "model_qualifier": "", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 21.2, "final_year_of_manufacture": null, "raw": ["018641", "000299", "0", "2020/Mar/19 09:44", "ATAG Verwarming Nederland", "ATAG", "I24S", "", "", "2019", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "21.2", "21.2", "", "", "89.1", "80.1", "", "58.5", "", "2", "", "", "102", "1", "2", "74", "4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "88.3", "99.4", "", "", "", "", "97.3"]} -{"pcdb_id": 18642, "brand_name": "ATAG", "model_name": "I18S", "model_qualifier": "", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 15.9, "final_year_of_manufacture": null, "raw": ["018642", "000299", "0", "2020/Apr/15 08:21", "ATAG Verwarming Nederland", "ATAG", "I18S", "", "", "2019", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "15.9", "15.9", "", "", "89.1", "80.1", "", "58.5", "", "2", "", "", "102", "1", "2", "74", "4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "88.6", "99.4", "", "", "", "", "97.3"]} -{"pcdb_id": 18643, "brand_name": "ATAG", "model_name": "IC Eonomiser 35 Plus", "model_qualifier": "", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 98.9, "comparative_hot_water_efficiency_pct": 83.6, "output_kw_max": 28.3, "final_year_of_manufacture": null, "raw": ["018643", "000299", "0", "2020/Apr/09 16:17", "ATAG Verwarming Nederland", "ATAG", "IC Eonomiser 35 Plus", "", "", "2019", "current", "1", "2", "1", "2", "1", "", "", "2", "2", "2", "28.3", "28.3", "", "", "89.1", "98.9", "", "83.6", "", "2", "", "", "104", "1", "2", "74", "4", "0", "", "", "", "0", "", "", "", "", "2", "6.297", "0.154", "0.0035", "0.20583", "11.494", "0.174", "0.002", "0.90833", "0.00002", "", "", "", "0025", "", "", "", "", "", "", "", "", "88.6", "99.5", "", "", "", "", "97.4"]} -{"pcdb_id": 18644, "brand_name": "ATAG", "model_name": "I18R", "model_qualifier": "", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 15.9, "final_year_of_manufacture": null, "raw": ["018644", "000299", "0", "2020/Mar/19 09:43", "ATAG Verwarming Nederland", "ATAG", "I18R", "", "", "2019", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "15.9", "15.9", "", "", "89.1", "80.1", "", "58.5", "", "2", "", "", "102", "1", "2", "74", "4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "88.6", "99.4", "", "", "", "", "97.3"]} -{"pcdb_id": 18645, "brand_name": "ATAG", "model_name": "I40S", "model_qualifier": "", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 35.3, "final_year_of_manufacture": null, "raw": ["018645", "000299", "0", "2020/Mar/19 09:20", "ATAG Verwarming Nederland", "ATAG", "I40S", "", "", "2019", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "35.3", "35.3", "", "", "89.1", "80.1", "", "58.5", "", "2", "", "", "102", "1", "2", "74", "4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "88.4", "99.4", "", "", "", "", "97.3"]} -{"pcdb_id": 18648, "brand_name": "ATAG", "model_name": "IC Economiser 27 Plus", "model_qualifier": "", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 98.9, "comparative_hot_water_efficiency_pct": 85.4, "output_kw_max": 23.2, "final_year_of_manufacture": null, "raw": ["018648", "000299", "0", "2020/Apr/09 16:16", "ATAG Verwarming Nederland", "ATAG", "IC Economiser 27 Plus", "", "", "2019", "current", "1", "2", "1", "2", "1", "", "", "2", "2", "2", "23.2", "23.2", "", "", "89.1", "98.9", "", "85.4", "", "2", "", "", "104", "1", "2", "74", "4", "0", "", "", "", "0", "", "", "", "", "2", "6.168", "0.153", "0.012", "0.02572", "11.449", "0.17", "0.006", "0.71988", "0.00006", "", "", "", "0025", "", "", "", "", "", "", "", "", "88.3", "99.4", "", "", "", "", "97.3"]} -{"pcdb_id": 18649, "brand_name": "ATAG", "model_name": "IC Economiser 39 Plus", "model_qualifier": "", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 98.9, "comparative_hot_water_efficiency_pct": 83.6, "output_kw_max": 28.3, "final_year_of_manufacture": null, "raw": ["018649", "000299", "0", "2020/Apr/09 16:15", "ATAG Verwarming Nederland", "ATAG", "IC Economiser 39 Plus", "", "", "2019", "current", "1", "2", "1", "2", "1", "", "", "2", "2", "2", "28.3", "28.3", "", "", "89.1", "98.9", "", "83.6", "", "2", "", "", "104", "1", "2", "74", "4", "0", "", "", "", "0", "", "", "", "", "2", "6.297", "0.154", "0.0035", "0.20583", "11.494", "0.174", "0.002", "0.90833", "0.00002", "", "", "", "0025", "", "", "", "", "", "", "", "", "88.6", "99.5", "", "", "", "", "97.4"]} -{"pcdb_id": 18650, "brand_name": "ATAG", "model_name": "i40C", "model_qualifier": "", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 88.2, "comparative_hot_water_efficiency_pct": 76.5, "output_kw_max": 28.3, "final_year_of_manufacture": null, "raw": ["018650", "000299", "0", "2020/Apr/09 16:15", "ATAG Verwarming Nederland", "ATAG", "i40C", "", "", "2019", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28.3", "28.3", "", "", "89.1", "88.2", "", "76.5", "", "2", "", "", "104", "1", "2", "74", "4", "0", "", "", "", "0", "", "", "", "", "2", "6.885", "0.179", "0.0008", "0.78828", "12.646", "0.196", "0.0004", "0.75508", "0.0", "", "", "", "0025", "", "", "", "", "", "", "", "", "88.6", "99.5", "", "", "", "", "97.4"]} -{"pcdb_id": 18651, "brand_name": "ATAG", "model_name": "i36C", "model_qualifier": "", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 86.9, "comparative_hot_water_efficiency_pct": 76.6, "output_kw_max": 28.3, "final_year_of_manufacture": null, "raw": ["018651", "000299", "0", "2020/Mar/19 09:46", "ATAG Verwarming Nederland", "ATAG", "i36C", "", "", "2019", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28.3", "28.3", "", "", "89.1", "86.9", "", "76.6", "", "2", "", "", "104", "1", "2", "74", "4", "0", "", "", "", "0", "", "", "", "", "1", "6.872", "0.182", "0.0008", "0.77574", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "88.6", "99.5", "", "", "", "", "97.4"]} -{"pcdb_id": 18652, "brand_name": "ATAG", "model_name": "I40R", "model_qualifier": "", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 35.3, "final_year_of_manufacture": null, "raw": ["018652", "000299", "0", "2020/Mar/19 09:46", "ATAG Verwarming Nederland", "ATAG", "I40R", "", "", "2019", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "35.3", "35.3", "", "", "89.1", "80.1", "", "58.5", "", "2", "", "", "102", "1", "2", "74", "4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "88.4", "99.4", "", "", "", "", "97.3"]} -{"pcdb_id": 18653, "brand_name": "ATAG", "model_name": "i28C", "model_qualifier": "", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 88.2, "comparative_hot_water_efficiency_pct": 77.4, "output_kw_max": 21.2, "final_year_of_manufacture": null, "raw": ["018653", "000299", "0", "2020/Apr/09 16:11", "ATAG Verwarming Nederland", "ATAG", "i28C", "", "", "2019", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "21.2", "21.2", "", "", "89.1", "88.2", "", "77.4", "", "2", "", "", "104", "1", "2", "74", "4", "0", "", "", "", "0", "", "", "", "", "2", "6.802", "0.169", "0.0008", "0.70169", "12.464", "0.178", "0.0004", "0.67557", "0.0", "", "", "", "0025", "", "", "", "", "", "", "", "", "88.3", "99.4", "", "", "", "", "97.3"]} -{"pcdb_id": 18654, "brand_name": "ATAG", "model_name": "I24R", "model_qualifier": "", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 21.2, "final_year_of_manufacture": null, "raw": ["018654", "000299", "0", "2020/Mar/19 09:45", "ATAG Verwarming Nederland", "ATAG", "I24R", "", "", "2019", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "21.2", "21.2", "", "", "89.1", "80.1", "", "58.5", "", "2", "", "", "102", "1", "2", "74", "4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "88.3", "99.4", "", "", "", "", "97.3"]} -{"pcdb_id": 18655, "brand_name": "ATAG", "model_name": "I32S", "model_qualifier": "", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 28.3, "final_year_of_manufacture": null, "raw": ["018655", "000299", "0", "2020/Mar/19 09:45", "ATAG Verwarming Nederland", "ATAG", "I32S", "", "", "2019", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "28.3", "28.3", "", "", "89.1", "80.1", "", "58.5", "", "2", "", "", "102", "1", "2", "74", "4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "88.6", "99.5", "", "", "", "", "97.4"]} -{"pcdb_id": 18656, "brand_name": "ATAG", "model_name": "I32R", "model_qualifier": "", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 28.3, "final_year_of_manufacture": null, "raw": ["018656", "000299", "0", "2020/Mar/19 09:45", "ATAG Verwarming Nederland", "ATAG", "I32R", "", "", "2019", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "28.3", "28.3", "", "", "89.1", "80.1", "", "58.5", "", "2", "", "", "102", "1", "2", "74", "4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "88.6", "99.5", "", "", "", "", "97.4"]} -{"pcdb_id": 18657, "brand_name": "ATAG", "model_name": "I15S", "model_qualifier": "", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 13.3, "final_year_of_manufacture": null, "raw": ["018657", "000299", "0", "2020/Mar/19 09:44", "ATAG Verwarming Nederland", "ATAG", "I15S", "", "", "2019", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "13.3", "13.3", "", "", "89.1", "80.1", "", "58.5", "", "2", "", "", "102", "1", "2", "74", "4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "88.8", "99.2", "", "", "", "", "97.2"]} -{"pcdb_id": 18658, "brand_name": "ATAG", "model_name": "i24C", "model_qualifier": "", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 88.2, "comparative_hot_water_efficiency_pct": 77.4, "output_kw_max": 21.2, "final_year_of_manufacture": null, "raw": ["018658", "000299", "0", "2020/Apr/09 16:10", "ATAG Verwarming Nederland", "ATAG", "i24C", "", "", "2019", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "21.2", "21.2", "", "", "89.1", "88.2", "", "77.4", "", "2", "", "", "104", "1", "2", "74", "4", "0", "", "", "", "0", "", "", "", "", "2", "6.806", "0.168", "0.0008", "0.70546", "12.475", "0.188", "0.0004", "0.67932", "0.0", "", "", "", "0025", "", "", "", "", "", "", "", "", "88.3", "99.4", "", "", "", "", "97.3"]} -{"pcdb_id": 18659, "brand_name": "ATAG", "model_name": "I15R", "model_qualifier": "", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 13.3, "final_year_of_manufacture": null, "raw": ["018659", "000299", "0", "2020/Mar/19 09:44", "ATAG Verwarming Nederland", "ATAG", "I15R", "", "", "2019", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "13.3", "13.3", "", "", "89.1", "80.1", "", "58.5", "", "2", "", "", "102", "1", "2", "74", "4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "88.8", "99.2", "", "", "", "", "97.2"]} -{"pcdb_id": 18660, "brand_name": "Warmflow", "model_name": "B26", "model_qualifier": "Agentis Boiler House 26", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 80.6, "comparative_hot_water_efficiency_pct": 58.9, "output_kw_max": 27.0, "final_year_of_manufacture": null, "raw": ["018660", "000063", "0", "2019/Sep/19 13:18", "Warmflow Engineering", "Warmflow", "B26", "Agentis Boiler House 26", "", "2019", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "21", "27", "", "", "88.4", "80.6", "", "58.9", "", "2", "", "", "201", "1", "1", " 146", " 0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.5", "95.6", "", "", "", "", "94.8"]} -{"pcdb_id": 18661, "brand_name": "Warmflow", "model_name": "E26", "model_qualifier": "Agentis External 26", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 80.6, "comparative_hot_water_efficiency_pct": 58.9, "output_kw_max": 27.0, "final_year_of_manufacture": null, "raw": ["018661", "000063", "0", "2019/Sep/19 13:18", "Warmflow Engineering", "Warmflow", "E26", "Agentis External 26", "", "2019", "current", "4", "1", "2", "1", "0", "", "", "2", "3", "2", "21.0000", "27.0000", "", "", "88.4", "80.6", "", "58.9", "", "2", "", "", "201", "1", "1", " 146", " 0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.5", "95.6", "", "", "", "", "94.8"]} -{"pcdb_id": 18662, "brand_name": "Warmflow", "model_name": "I26", "model_qualifier": "Agentis Internal 26", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 80.6, "comparative_hot_water_efficiency_pct": 58.9, "output_kw_max": 27.0, "final_year_of_manufacture": null, "raw": ["018662", "000063", "0", "2019/Sep/19 13:17", "Warmflow Engineering", "Warmflow", "I26", "Agentis Internal 26", "", "2019", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "21.0000", "27.0000", "", "", "88.4", "80.6", "", "58.9", "", "2", "", "", "201", "1", "1", " 146", " 0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.5", "95.6", "", "", "", "", "94.8"]} -{"pcdb_id": 18663, "brand_name": "Alpha", "model_name": "E-Tec", "model_qualifier": "25R", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 24.0, "final_year_of_manufacture": null, "raw": ["018663", "000001", "0", "2020/Jan/06 15:33", "Alpha Therm", "Alpha", "E-Tec", "25R", "3.028465", "2018", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24", "24", "", "", "88.3", "79.3", "", "57.9", "", "2", "", "", "102", "1", "2", " 27", " 6", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "1005", "", "", "", "", "", "", "", "", "88.1", "97.6", "", "", "", "", "95.8"]} -{"pcdb_id": 18665, "brand_name": "HRM", "model_name": "X1", "model_qualifier": "LOW NOX CONDENSING 12 - 16 Kw", "winter_efficiency_pct": 86.6, "summer_efficiency_pct": 78.8, "comparative_hot_water_efficiency_pct": 57.6, "output_kw_max": 16.0, "final_year_of_manufacture": null, "raw": ["018665", "000098", "0", "2019/Sep/11 13:39", "HRM Boilers", "HRM", "X1", "LOW NOX CONDENSING 12 - 16 Kw", "", "2018", "current", "4", "2", "2", "1", "0", "", "", "2", "2", "2", "12", "16", "", "", "86.6", "78.8", "", "57.6", "", "2", "", "", "201", "1", "1", " 138", " 0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "89.4", "91.9", "", "", "", "", "91.4"]} -{"pcdb_id": 18666, "brand_name": "HRM", "model_name": "X 1 SYSTEM", "model_qualifier": "LOW NOX CONDENSING 12 - 16 Kw", "winter_efficiency_pct": 86.6, "summer_efficiency_pct": 78.8, "comparative_hot_water_efficiency_pct": 57.6, "output_kw_max": 16.0, "final_year_of_manufacture": null, "raw": ["018666", "000098", "0", "2019/Sep/11 13:38", "HRM Boilers", "HRM", "X 1 SYSTEM", "LOW NOX CONDENSING 12 - 16 Kw", "", "2018", "current", "4", "2", "2", "1", "0", "", "", "2", "2", "2", "12", "16", "", "", "86.6", "78.8", "", "57.6", "", "2", "", "", "201", "1", "1", " 138", " 0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "89.4", "91.9", "", "", "", "", "91.4"]} -{"pcdb_id": 18667, "brand_name": "Warmflow", "model_name": "E21C", "model_qualifier": "AGENTIS EXTERNAL COMBI 21", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 90.0, "comparative_hot_water_efficiency_pct": 64.5, "output_kw_max": 21.0, "final_year_of_manufacture": null, "raw": ["018667", "000063", "0", "2020/Jan/22 13:11", "Warmflow Engineering", "Warmflow", "E21C", "AGENTIS EXTERNAL COMBI 21", "", "2019", "current", "4", "1", "2", "2", "0", "", "", "2", "3", "2", "15.0000", "21.0000", "", "", "88.7", "90.0", "", "64.5", "", "2", "", "", "203", "1", "1", "163", "3", "1", "2", "0", "38", "0", "20", "4", "58", "", "1", "8.487", "0.117", "0.0", "2.30726", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.1", "96.5", "", "", "", "", "95.5"]} -{"pcdb_id": 18668, "brand_name": "Warmflow", "model_name": "E26C", "model_qualifier": "AGENTIS EXTERNAL COMBI 26", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 90.0, "comparative_hot_water_efficiency_pct": 62.6, "output_kw_max": 27.0, "final_year_of_manufacture": null, "raw": ["018668", "000063", "0", "2020/Jan/22 13:11", "Warmflow Engineering", "Warmflow", "E26C", "AGENTIS EXTERNAL COMBI 26", "", "2019", "current", "4", "1", "2", "2", "0", "", "", "2", "3", "2", "21.0000", "27.0000", "", "", "88.2", "90.0", "", "62.6", "", "2", "", "", "203", "1", "1", "140", "3", "1", "2", "0", "38", "0", "20", "4", "58", "", "1", "8.751", "0.108", "0.0", "2.56085", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.1", "95.1", "", "", "", "", "94.3"]} -{"pcdb_id": 18669, "brand_name": "Warmflow", "model_name": "E33C", "model_qualifier": "AGENTIS EXTERNAL COMBI 33", "winter_efficiency_pct": 87.4, "summer_efficiency_pct": 89.9, "comparative_hot_water_efficiency_pct": 57.3, "output_kw_max": 32.7, "final_year_of_manufacture": null, "raw": ["018669", "000063", "0", "2020/Jan/22 13:11", "Warmflow Engineering", "Warmflow", "E33C", "AGENTIS EXTERNAL COMBI 33", "", "2019", "current", "4", "1", "2", "2", "0", "", "", "2", "3", "2", "27", "32.7", "", "", "87.4", "89.9", "", "57.3", "", "2", "", "", "203", "1", "1", "148", "3", "1", "2", "0", "38", "0", "20", "4", "58", "", "1", "9.552", "0.088", "0.0", "3.31777", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.7", "93.3", "", "", "", "", "92.8"]} -{"pcdb_id": 18670, "brand_name": "Warmflow", "model_name": "I21C", "model_qualifier": "AGENTIS INTERNAL COMBI 21", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 90.0, "comparative_hot_water_efficiency_pct": 64.5, "output_kw_max": 21.0, "final_year_of_manufacture": null, "raw": ["018670", "000063", "0", "2020/Jan/22 13:11", "Warmflow Engineering", "Warmflow", "I21C", "AGENTIS INTERNAL COMBI 21", "", "2019", "current", "4", "1", "1", "2", "0", "", "", "2", "3", "2", "15.0000", "21.0000", "", "", "88.7", "90.0", "", "64.5", "", "2", "", "", "203", "1", "1", "163", "3", "1", "2", "0", "38", "0", "20", "4", "58", "", "1", "8.487", "0.117", "0.0", "2.30726", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.1", "96.5", "", "", "", "", "95.5"]} -{"pcdb_id": 18671, "brand_name": "Warmflow", "model_name": "I26C", "model_qualifier": "AGENTIS INTERNAL COMBI 26", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 90.0, "comparative_hot_water_efficiency_pct": 62.6, "output_kw_max": 27.0, "final_year_of_manufacture": null, "raw": ["018671", "000063", "0", "2020/Jan/22 13:11", "Warmflow Engineering", "Warmflow", "I26C", "AGENTIS INTERNAL COMBI 26", "", "2019", "current", "4", "1", "1", "2", "0", "", "", "2", "3", "2", "21.0000", "27.0000", "", "", "88.2", "90.0", "", "62.6", "", "2", "", "", "203", "1", "1", "140", "3", "1", "2", "0", "38", "0", "20", "4", "58", "", "1", "8.751", "0.108", "0.0", "2.56085", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.1", "95.1", "", "", "", "", "94.3"]} -{"pcdb_id": 18672, "brand_name": "Warmflow", "model_name": "I33C", "model_qualifier": "AGENTIS INTERNAL COMBI 33", "winter_efficiency_pct": 87.4, "summer_efficiency_pct": 89.9, "comparative_hot_water_efficiency_pct": 57.3, "output_kw_max": 32.7, "final_year_of_manufacture": null, "raw": ["018672", "000063", "0", "2020/Jan/22 13:11", "Warmflow Engineering", "Warmflow", "I33C", "AGENTIS INTERNAL COMBI 33", "", "2019", "current", "4", "1", "1", "2", "0", "", "", "2", "3", "2", "27", "32.7", "", "", "87.4", "89.9", "", "57.3", "", "2", "", "", "203", "1", "1", "148", "3", "1", "2", "0", "38", "0", "20", "4", "58", "", "1", "9.552", "0.088", "0.0", "3.31777", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.7", "93.2", "", "", "", "", "92.8"]} -{"pcdb_id": 18673, "brand_name": "Warmflow", "model_name": "B21", "model_qualifier": "Agentis Boiler House 21", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 80.9, "comparative_hot_water_efficiency_pct": 59.1, "output_kw_max": 21.0, "final_year_of_manufacture": null, "raw": ["018673", "000063", "0", "2019/Sep/25 15:06", "Warmflow Engineering", "Warmflow", "B21", "Agentis Boiler House 21", "", "2019", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "15.0000", "21.0000", "", "", "88.7", "80.9", "", "59.1", "", "2", "", "", "201", "1", "1", " 152", " 0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.8", "96.2", "", "", "", "", "95.4"]} -{"pcdb_id": 18674, "brand_name": "Warmflow", "model_name": "E21", "model_qualifier": "Agentis External 21", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 80.9, "comparative_hot_water_efficiency_pct": 59.1, "output_kw_max": 21.0, "final_year_of_manufacture": null, "raw": ["018674", "000063", "0", "2019/Sep/25 15:07", "Warmflow Engineering", "Warmflow", "E21", "Agentis External 21", "", "2019", "current", "4", "1", "2", "1", "0", "", "", "2", "3", "2", "15.0000", "21.0000", "", "", "88.7", "80.9", "", "59.1", "", "2", "", "", "201", "1", "1", " 152", " 0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.8", "96.2", "", "", "", "", "95.4"]} -{"pcdb_id": 18675, "brand_name": "Warmflow", "model_name": "I21", "model_qualifier": "Agentis Internal 21", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 80.9, "comparative_hot_water_efficiency_pct": 59.1, "output_kw_max": 21.0, "final_year_of_manufacture": null, "raw": ["018675", "000063", "0", "2019/Sep/25 15:07", "Warmflow Engineering", "Warmflow", "I21", "Agentis Internal 21", "", "2019", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "15.0000", "21.0000", "", "", "88.7", "80.9", "", "59.1", "", "2", "", "", "201", "1", "1", " 152", " 0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.8", "96.2", "", "", "", "", "95.4"]} -{"pcdb_id": 18676, "brand_name": "Warmflow", "model_name": "B33", "model_qualifier": "Agentis Boiler House 33", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 32.7, "final_year_of_manufacture": null, "raw": ["018676", "000063", "0", "2019/Sep/25 17:10", "Warmflow Engineering", "Warmflow", "B33", "Agentis Boiler House 33", "", "2019", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "27.1000", "32.7000", "", "", "88.0", "80.2", "", "58.6", "", "2", "", "", "201", "1", "1", " 147", " 0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.7", "94.7", "", "", "", "", "94.0"]} -{"pcdb_id": 18677, "brand_name": "Warmflow", "model_name": "E33", "model_qualifier": "Agentis External 33", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 32.7, "final_year_of_manufacture": null, "raw": ["018677", "000063", "0", "2019/Sep/25 17:10", "Warmflow Engineering", "Warmflow", "E33", "Agentis External 33", "", "2019", "current", "4", "1", "2", "1", "0", "", "", "2", "3", "2", "27.1000", "32.7000", "", "", "88.0", "80.2", "", "58.6", "", "2", "", "", "201", "1", "1", " 147", " 0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.7", "94.7", "", "", "", "", "94.0"]} -{"pcdb_id": 18678, "brand_name": "Warmflow", "model_name": "I33", "model_qualifier": "Agentis Internal 33", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 32.7, "final_year_of_manufacture": null, "raw": ["018678", "000063", "0", "2019/Sep/25 17:10", "Warmflow Engineering", "Warmflow", "I33", "Agentis Internal 33", "", "2019", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "27.1000", "32.7000", "", "", "88.0", "80.2", "", "58.6", "", "2", "", "", "201", "1", "1", " 147", " 0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.7", "94.7", "", "", "", "", "94.0"]} -{"pcdb_id": 18679, "brand_name": "Warmflow", "model_name": "E44", "model_qualifier": "Agentis External 44", "winter_efficiency_pct": 87.5, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 44.0, "final_year_of_manufacture": null, "raw": ["018679", "000063", "0", "2019/Oct/21 09:47", "Warmflow Engineering", "Warmflow", "E44", "Agentis External 44", "", "2019", "current", "4", "1", "2", "1", "0", "", "", "2", "3", "2", "33", "44", "", "", "87.5", "79.7", "", "58.2", "", "2", "", "", "201", "1", "1", "190", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "89.6", "94.1", "", "", "", "", "93.2"]} -{"pcdb_id": 18680, "brand_name": "Warmflow", "model_name": "I44", "model_qualifier": "Agentis Internal 44", "winter_efficiency_pct": 87.5, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 44.0, "final_year_of_manufacture": null, "raw": ["018680", "000063", "0", "2019/Oct/21 09:47", "Warmflow Engineering", "Warmflow", "I44", "Agentis Internal 44", "", "2019", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "33", "44", "", "", "87.5", "79.7", "", "58.2", "", "2", "", "", "201", "1", "1", "190", " 0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "89.6", "94.1", "", "", "", "", "93.2"]} -{"pcdb_id": 18681, "brand_name": "Baxi", "model_name": "818 SYSTEM", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 18.0, "final_year_of_manufacture": null, "raw": ["018681", "000005", "0", "2020/Jan/20 13:48", "Baxi Heating", "Baxi", "818 SYSTEM", "", "41-470-73", "2019", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18", "18", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", " 30", " 3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "88.2", "97.8", "", "", "", "", "96.0"]} -{"pcdb_id": 18682, "brand_name": "Baxi", "model_name": "824 SYSTEM", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 24.0, "final_year_of_manufacture": null, "raw": ["018682", "000005", "0", "2020/Jan/20 13:48", "Baxi Heating", "Baxi", "824 SYSTEM", "", "41-470-74", "2019", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24", "24", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", " 60", " 3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "88.0", "97.8", "", "", "", "", "95.9"]} -{"pcdb_id": 18683, "brand_name": "Baxi", "model_name": "825 COMBI", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 56.1, "output_kw_max": 20.0, "final_year_of_manufacture": null, "raw": ["018683", "000005", "0", "2020/Jan/20 13:49", "Baxi Heating", "Baxi", "825 COMBI", "", "47-077-38", "2019", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "20", "20", "", "", "88.4", "79.8", "", "56.1", "", "2", "", "", "104", "1", "2", " 28", " 3", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "88.0", "97.8", "", "", "", "", "95.9"]} -{"pcdb_id": 18684, "brand_name": "Baxi", "model_name": "830 COMBI", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 56.1, "output_kw_max": 20.0, "final_year_of_manufacture": null, "raw": ["018684", "000005", "0", "2020/Jan/20 13:49", "Baxi Heating", "Baxi", "830 COMBI", "", "47-077-39", "2019", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "20", "20", "", "", "88.4", "79.8", "", "56.1", "", "2", "", "", "104", "1", "2", " 36", " 3", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "88.0", "97.8", "", "", "", "", "95.9"]} -{"pcdb_id": 18685, "brand_name": "Baxi", "model_name": "836 COMBI", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 56.1, "output_kw_max": 25.0, "final_year_of_manufacture": null, "raw": ["018685", "000005", "0", "2020/Jan/20 13:50", "Baxi Heating", "Baxi", "836 COMBI", "", "47-077-40", "2019", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "25", "25", "", "", "88.4", "79.8", "", "56.1", "", "2", "", "", "104", "1", "2", " 72", " 3", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "88.1", "97.8", "", "", "", "", "96.0"]} -{"pcdb_id": 18686, "brand_name": "Worcester", "model_name": "2000", "model_qualifier": "GC2000iW 25 C NG", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 86.6, "comparative_hot_water_efficiency_pct": 75.5, "output_kw_max": 20.0, "final_year_of_manufacture": null, "raw": ["018686", "000035", "0", "2020/Jul/17 08:13", "Bosch Thermotechnology", "Worcester", "2000", "GC2000iW 25 C NG", "47-800-25", "2019", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "20.000", "20.000", "", "", "88.4", "86.6", "", "75.5", "", "2", "", "", "104", "1", "2", " 28", " 3", "0", "", "", "", "0", "", "", "", "", "1", "6.973", "0.078", "0.0024", "0.8438", "", "", "", "", "", "", "", "", "8305", "", "", "", "", "", "", "", "", "87.8", "98.0", "", "", "", "", "96.1"]} -{"pcdb_id": 18687, "brand_name": "Worcester", "model_name": "2000", "model_qualifier": "GC2000iW 30 C NG", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 86.6, "comparative_hot_water_efficiency_pct": 76.3, "output_kw_max": 20.0, "final_year_of_manufacture": null, "raw": ["018687", "000035", "0", "2020/Jul/01 12:16", "Bosch Thermotechnology", "Worcester", "2000", "GC2000iW 30 C NG", "47-800-24", "2019", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "20.000", "20.000", "", "", "88.4", "86.6", "", "76.3", "", "2", "", "", "104", "1", "2", " 28", " 3", "0", "", "", "", "0", "", "", "", "", "1", "6.901", "0.069", "0.005", "0.75911", "", "", "", "", "", "", "", "", "8305", "", "", "", "", "", "", "", "", "87.8", "98.0", "", "", "", "", "96.1"]} -{"pcdb_id": 18688, "brand_name": "Glow-worm", "model_name": "MicraCom", "model_qualifier": "24c-AS/1 (H-GB)", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 86.6, "comparative_hot_water_efficiency_pct": 73.6, "output_kw_max": 18.3, "final_year_of_manufacture": null, "raw": ["018688", "000207", "0", "2020/Jan/27 09:16", "Glow-worm", "Glow-worm", "MicraCom", "24c-AS/1 (H-GB)", "", "2019", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "18.3", "18.3", "", "", "88.0", "86.6", "", "73.6", "", "2", "", "", "104", "1", "2", " 27", " 2", "0", "", "", "", "0", "", "", "", "", "1", "7.151", "0.067", "0.0008", "1.02612", "", "", "", "", "", "", "", "", "0085", "", "", "", "", "", "", "", "", "87.8", "96.9", "", "", "", "", "95.1"]} -{"pcdb_id": 18689, "brand_name": "Glow-worm", "model_name": "MicraCom", "model_qualifier": "28c-AS/1 (H-GB)", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 86.6, "comparative_hot_water_efficiency_pct": 67.9, "output_kw_max": 23.9, "final_year_of_manufacture": null, "raw": ["018689", "000207", "0", "2020/Jan/27 09:16", "Glow-worm", "Glow-worm", "MicraCom", "28c-AS/1 (H-GB)", "", "2019", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "23.9", "23.9", "", "", "88.3", "86.6", "", "67.9", "", "2", "", "", "104", "1", "2", " 35", " 2", "0", "", "", "", "0", "", "", "", "", "1", "7.759", "0.07", "0.0203", "1.49449", "", "", "", "", "", "", "", "", "0085", "", "", "", "", "", "", "", "", "87.8", "97.7", "", "", "", "", "95.8"]} -{"pcdb_id": 18690, "brand_name": "Heat Line", "model_name": "Enza", "model_qualifier": "24c-AS/1 (H-GB)", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 86.6, "comparative_hot_water_efficiency_pct": 73.6, "output_kw_max": 18.3, "final_year_of_manufacture": null, "raw": ["018690", "000031", "0", "2020/Jan/27 09:18", "Vaillant", "Heat Line", "Enza", "24c-AS/1 (H-GB)", "", "2019", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "18.3", "18.3", "", "", "88.0", "86.6", "", "73.6", "", "2", "", "", "104", "1", "2", " 27", " 2", "0", "", "", "", "0", "", "", "", "", "1", "7.151", "0.067", "0.0008", "1.02612", "", "", "", "", "", "", "", "", "0045", "", "", "", "", "", "", "", "", "87.8", "96.9", "", "", "", "", "95.1"]} -{"pcdb_id": 18691, "brand_name": "Heat Line", "model_name": "Enza", "model_qualifier": "28c-AS/1 (H-GB)", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 86.6, "comparative_hot_water_efficiency_pct": 67.9, "output_kw_max": 23.9, "final_year_of_manufacture": null, "raw": ["018691", "000031", "0", "2020/Jan/27 09:18", "Vaillant", "Heat Line", "Enza", "28c-AS/1 (H-GB)", "", "2019", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "23.9", "23.9", "", "", "88.3", "86.6", "", "67.9", "", "2", "", "", "104", "1", "2", " 35", " 2", "0", "", "", "", "0", "", "", "", "", "1", "7.759", "0.07", "0.0203", "1.49449", "", "", "", "", "", "", "", "", "0045", "", "", "", "", "", "", "", "", "87.8", "97.7", "", "", "", "", "95.8"]} -{"pcdb_id": 18692, "brand_name": "Ideal", "model_name": "LOGIC MAX COMBI", "model_qualifier": "C24IE", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 69.8, "output_kw_max": 24.2, "final_year_of_manufacture": null, "raw": ["018692", "000008", "0", "2020/Jan/29 13:26", "Ideal Boilers", "Ideal", "LOGIC MAX COMBI", "C24IE", "47-349-87", "2020", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "88.9", "87.3", "", "69.8", "", "2", "", "", "104", "1", "2", "42", "5", "0", "", "", "", "0", "", "", "", "", "1", "7.549", "0.076", "0.0027", "1.4524", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "", "", "", "", "89.8", "98.3", "", "", "", "", "96.7"]} -{"pcdb_id": 18693, "brand_name": "Ideal", "model_name": "LOGIC MAX COMBI", "model_qualifier": "C24P IE", "winter_efficiency_pct": 90.1, "summer_efficiency_pct": 81.5, "comparative_hot_water_efficiency_pct": 57.3, "output_kw_max": 24.2, "final_year_of_manufacture": null, "raw": ["018693", "000008", "0", "2020/Jan/13 11:12", "Ideal Boilers", "Ideal", "LOGIC MAX COMBI", "C24P IE", "", "2020", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "90.1", "81.5", "", "57.3", "", "2", "1", "", "104", "1", "2", " 42", "5", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "", "", "", "", "92.0", "100.8", "", "", "", "", "99.1"]} -{"pcdb_id": 18694, "brand_name": "Ideal", "model_name": "LOGIC MAX COMBI", "model_qualifier": "C30IE", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 70.4, "output_kw_max": 24.2, "final_year_of_manufacture": null, "raw": ["018694", "000008", "0", "2020/Jan/29 13:26", "Ideal Boilers", "Ideal", "LOGIC MAX COMBI", "C30IE", "47-349-88", "2020", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "88.9", "87.3", "", "70.4", "", "2", "", "", "104", "1", "2", " 31", " 5", "0", "", "", "", "0", "", "", "", "", "1", "7.476", "0.074", "0.0025", "1.38244", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "", "", "", "", "89.8", "98.3", "", "", "", "", "96.7"]} -{"pcdb_id": 18695, "brand_name": "Ideal", "model_name": "LOGIC MAX COMBI", "model_qualifier": "C30P IE", "winter_efficiency_pct": 90.1, "summer_efficiency_pct": 81.5, "comparative_hot_water_efficiency_pct": 57.3, "output_kw_max": 24.2, "final_year_of_manufacture": null, "raw": ["018695", "000008", "0", "2020/Jan/13 11:12", "Ideal Boilers", "Ideal", "LOGIC MAX COMBI", "C30P IE", "47-349-88", "2020", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "90.1", "81.5", "", "57.3", "", "2", "1", "", "104", "1", "2", " 31", "5", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "", "", "", "", "92.0", "100.8", "", "", "", "", "99.1"]} -{"pcdb_id": 18696, "brand_name": "Ideal", "model_name": "LOGIC MAX COMBI", "model_qualifier": "C35IE", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 71.1, "output_kw_max": 24.2, "final_year_of_manufacture": null, "raw": ["018696", "000008", "0", "2020/Jan/22 13:12", "Ideal Boilers", "Ideal", "LOGIC MAX COMBI", "C35IE", "47-349-89", "2020", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "89.0", "87.3", "", "71.1", "", "2", "", "", "104", "1", "2", "29", "5", "0", "", "", "", "0", "", "", "", "", "1", "7.411", "0.074", "0.0025", "1.32446", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "", "", "", "", "90.0", "98.6", "", "", "", "", "96.9"]} -{"pcdb_id": 18697, "brand_name": "Ideal", "model_name": "LOGIC MAX HEAT", "model_qualifier": "H12IE", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 12.0, "final_year_of_manufacture": null, "raw": ["018697", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "LOGIC MAX HEAT", "H12IE", "41-796-65", "2020", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "12.0", "12.0", "", "", "88.8", "79.8", "", "58.3", "", "2", "", "", "102", "1", "2", "20", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "90.0", "98.0", "", "", "", "", "96.5"]} -{"pcdb_id": 18698, "brand_name": "Ideal", "model_name": "LOGIC MAX HEAT", "model_qualifier": "H15IE", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 15.0, "final_year_of_manufacture": null, "raw": ["018698", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "LOGIC MAX HEAT", "H15IE", "41-796-66", "2020", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "15.0", "15.0", "", "", "88.7", "79.7", "", "58.2", "", "2", "", "", "102", "1", "2", "21", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "90.0", "97.8", "", "", "", "", "96.4"]} -{"pcdb_id": 18699, "brand_name": "Ideal", "model_name": "LOGIC MAX HEAT", "model_qualifier": "H18IE", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 18.0, "final_year_of_manufacture": null, "raw": ["018699", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "LOGIC MAX HEAT", "H18IE", "41-796-67", "2020", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18.0", "18.0", "", "", "89.1", "80.1", "", "58.5", "", "2", "", "", "102", "1", "2", "26", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "89.8", "98.8", "", "", "", "", "97.1"]} -{"pcdb_id": 18700, "brand_name": "Ideal", "model_name": "LOGIC MAX HEAT", "model_qualifier": "H24IE", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 24.2, "final_year_of_manufacture": null, "raw": ["018700", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "LOGIC MAX HEAT", "H24IE", "41-796-68", "2020", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "88.9", "79.9", "", "58.4", "", "2", "", "", "102", "1", "2", "42", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "89.8", "98.3", "", "", "", "", "96.7"]} -{"pcdb_id": 18701, "brand_name": "Ideal", "model_name": "LOGIC MAX HEAT", "model_qualifier": "H24P IE", "winter_efficiency_pct": 89.9, "summer_efficiency_pct": 80.9, "comparative_hot_water_efficiency_pct": 59.1, "output_kw_max": 24.2, "final_year_of_manufacture": null, "raw": ["018701", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "LOGIC MAX HEAT", "H24P IE", "", "2020", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "89.9", "80.9", "", "59.1", "", "2", "1", "", "102", "1", "2", "42", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "91.8", "100.5", "", "", "", "", "98.8"]} -{"pcdb_id": 18702, "brand_name": "Ideal", "model_name": "LOGIC MAX HEAT", "model_qualifier": "H30IE", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 30.3, "final_year_of_manufacture": null, "raw": ["018702", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "LOGIC MAX HEAT", "H30IE", "41-796-69", "2020", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "30.3", "30.3", "", "", "88.9", "79.9", "", "58.4", "", "2", "", "", "102", "1", "2", "31", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "89.9", "98.3", "", "", "", "", "96.7"]} -{"pcdb_id": 18703, "brand_name": "Ideal", "model_name": "LOGIC MAX HEAT", "model_qualifier": "H30P IE", "winter_efficiency_pct": 89.9, "summer_efficiency_pct": 80.9, "comparative_hot_water_efficiency_pct": 59.1, "output_kw_max": 30.3, "final_year_of_manufacture": null, "raw": ["018703", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "LOGIC MAX HEAT", "H30P IE", "41-796-69", "2020", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "30.3", "30.3", "", "", "89.9", "80.9", "", "59.1", "", "2", "1", "", "102", "1", "2", "31", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "91.9", "100.5", "", "", "", "", "98.9"]} -{"pcdb_id": 18704, "brand_name": "Ideal", "model_name": "LOGIC MAX SYSTEM", "model_qualifier": "S15IE", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 15.0, "final_year_of_manufacture": null, "raw": ["018704", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "LOGIC MAX SYSTEM", "S15IE", "41-796-61", "2020", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "15.0", "15.0", "", "", "88.7", "79.7", "", "58.2", "", "2", "", "", "102", "1", "2", "21", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "90.0", "97.8", "", "", "", "", "96.4"]} -{"pcdb_id": 18705, "brand_name": "Ideal", "model_name": "LOGIC MAX SYSTEM", "model_qualifier": "S18IE", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 18.0, "final_year_of_manufacture": null, "raw": ["018705", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "LOGIC MAX SYSTEM", "S18IE", "41-796-62", "2020", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18.0", "18.0", "", "", "89.1", "80.1", "", "58.5", "", "2", "", "", "102", "1", "2", "26", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "89.8", "98.8", "", "", "", "", "97.1"]} -{"pcdb_id": 18706, "brand_name": "Ideal", "model_name": "LOGIC MAX SYSTEM", "model_qualifier": "S24IE", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 24.2, "final_year_of_manufacture": null, "raw": ["018706", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "LOGIC MAX SYSTEM", "S24IE", "41-796-63", "2020", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "88.9", "79.9", "", "58.4", "", "2", "", "", "102", "1", "2", "42", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "89.8", "98.3", "", "", "", "", "96.7"]} -{"pcdb_id": 18707, "brand_name": "Ideal", "model_name": "LOGIC MAX SYSTEM", "model_qualifier": "S24P IE", "winter_efficiency_pct": 89.9, "summer_efficiency_pct": 80.9, "comparative_hot_water_efficiency_pct": 59.1, "output_kw_max": 24.2, "final_year_of_manufacture": null, "raw": ["018707", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "LOGIC MAX SYSTEM", "S24P IE", "", "2020", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "89.9", "80.9", "", "59.1", "", "2", "1", "", "102", "1", "2", "42", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "91.8", "100.5", "", "", "", "", "98.8"]} -{"pcdb_id": 18708, "brand_name": "Ideal", "model_name": "LOGIC MAX SYSTEM", "model_qualifier": "S30IE", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 30.3, "final_year_of_manufacture": null, "raw": ["018708", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "LOGIC MAX SYSTEM", "S30IE", "41-796-64", "2020", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "30.3", "30.3", "", "", "88.9", "79.9", "", "58.4", "", "2", "", "", "102", "1", "2", "31", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "89.9", "98.3", "", "", "", "", "96.7"]} -{"pcdb_id": 18709, "brand_name": "Ideal", "model_name": "LOGIC MAX SYSTEM", "model_qualifier": "S30P IE", "winter_efficiency_pct": 89.9, "summer_efficiency_pct": 80.9, "comparative_hot_water_efficiency_pct": 59.1, "output_kw_max": 30.3, "final_year_of_manufacture": null, "raw": ["018709", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "LOGIC MAX SYSTEM", "S30P IE", "41-796-64", "2020", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "30.3", "30.3", "", "", "89.9", "80.9", "", "59.1", "", "2", "1", "", "102", "1", "2", "31", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "91.9", "100.5", "", "", "", "", "98.9"]} -{"pcdb_id": 18710, "brand_name": "Ideal", "model_name": "VOGUE MAX COMBI", "model_qualifier": "26IE", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 87.2, "comparative_hot_water_efficiency_pct": 76.2, "output_kw_max": 18.0, "final_year_of_manufacture": null, "raw": ["018710", "000008", "0", "2020/Jan/27 10:06", "Ideal Boilers", "Ideal", "VOGUE MAX COMBI", "26IE", "47-349-84", "2020", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "18.0", "18.0", "", "", "88.5", "87.2", "", "76.2", "", "2", "", "", "104", "1", "2", "47", "3", "0", "", "", "", "0", "", "", "", "", "1", "6.915", "0.085", "0.0012", "0.83988", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "", "", "", "", "89.6", "97.5", "", "", "", "", "96.0"]} -{"pcdb_id": 18711, "brand_name": "Ideal", "model_name": "VOGUE MAX COMBI", "model_qualifier": "26P IE", "winter_efficiency_pct": 89.5, "summer_efficiency_pct": 80.9, "comparative_hot_water_efficiency_pct": 56.9, "output_kw_max": 18.0, "final_year_of_manufacture": null, "raw": ["018711", "000008", "0", "2020/Jan/27 10:06", "Ideal Boilers", "Ideal", "VOGUE MAX COMBI", "26P IE", "47-349-84", "2020", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "18.0", "18.0", "", "", "89.5", "80.9", "", "56.9", "", "2", "1", "", "104", "1", "2", "47", "3", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "", "", "", "", "91.5", "99.7", "", "", "", "", "98.1"]} -{"pcdb_id": 18712, "brand_name": "Ideal", "model_name": "VOGUE MAX COMBI", "model_qualifier": "32IE", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 87.2, "comparative_hot_water_efficiency_pct": 77.6, "output_kw_max": 26.0, "final_year_of_manufacture": null, "raw": ["018712", "000008", "0", "2020/Jan/27 10:06", "Ideal Boilers", "Ideal", "VOGUE MAX COMBI", "32IE", "47-349-85", "2020", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "26.0", "26.0", "", "", "88.6", "87.2", "", "77.6", "", "2", "", "", "104", "1", "2", "63", "3", "0", "", "", "", "0", "", "", "", "", "1", "6.79", "0.087", "0.001", "0.72046", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "", "", "", "", "89.6", "97.6", "", "", "", "", "96.1"]} -{"pcdb_id": 18713, "brand_name": "Ideal", "model_name": "VOGUE MAX COMBI", "model_qualifier": "32P IE", "winter_efficiency_pct": 89.6, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 56.9, "output_kw_max": 26.0, "final_year_of_manufacture": null, "raw": ["018713", "000008", "0", "2020/Jan/27 10:06", "Ideal Boilers", "Ideal", "VOGUE MAX COMBI", "32P IE", "47-349-85", "2020", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "26.0", "26.0", "", "", "89.6", "81.0", "", "56.9", "", "2", "1", "", "104", "1", "2", "63", "3", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "", "", "", "", "91.5", "99.7", "", "", "", "", "98.2"]} -{"pcdb_id": 18714, "brand_name": "Ideal", "model_name": "VOGUE MAX COMBI", "model_qualifier": "40IE", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 87.2, "comparative_hot_water_efficiency_pct": 77.2, "output_kw_max": 32.0, "final_year_of_manufacture": null, "raw": ["018714", "000008", "0", "2020/Jan/27 10:08", "Ideal Boilers", "Ideal", "VOGUE MAX COMBI", "40IE", "47-349-86", "2020", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "32.0", "32.0", "", "", "88.5", "87.2", "", "77.2", "", "2", "", "", "104", "1", "2", "44", "3", "0", "", "", "", "0", "", "", "", "", "1", "6.821", "0.085", "0.0011", "0.74964", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "", "", "", "", "89.6", "97.3", "", "", "", "", "95.8"]} -{"pcdb_id": 18715, "brand_name": "Ideal", "model_name": "VOGUE MAX COMBI", "model_qualifier": "40P IE", "winter_efficiency_pct": 89.5, "summer_efficiency_pct": 80.9, "comparative_hot_water_efficiency_pct": 56.9, "output_kw_max": 32.0, "final_year_of_manufacture": null, "raw": ["018715", "000008", "0", "2020/Jan/27 10:09", "Ideal Boilers", "Ideal", "VOGUE MAX COMBI", "40P IE", "47-349-86", "2020", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "32.0", "32.0", "", "", "89.5", "80.9", "", "56.9", "", "2", "1", "", "104", "1", "2", "44", "3", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "", "", "", "", "91.5", "99.5", "", "", "", "", "98.0"]} -{"pcdb_id": 18716, "brand_name": "Ideal", "model_name": "VOGUE MAX SYSTEM", "model_qualifier": "15IE", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 15.0, "final_year_of_manufacture": null, "raw": ["018716", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "VOGUE MAX SYSTEM", "15IE", "41-750-57", "2020", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "15.0", "15.0", "", "", "88.2", "79.2", "", "57.9", "", "2", "", "", "102", "1", "2", "25", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "89.5", "96.8", "", "", "", "", "95.4"]} -{"pcdb_id": 18717, "brand_name": "Ideal", "model_name": "VOGUE MAX SYSTEM", "model_qualifier": "15P IE", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 15.0, "final_year_of_manufacture": null, "raw": ["018717", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "VOGUE MAX SYSTEM", "15P IE", "41-750-57", "2020", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "15.0", "15.0", "", "", "89.2", "80.2", "", "58.6", "", "2", "1", "", "102", "1", "2", "25", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "91.5", "98.9", "", "", "", "", "97.5"]} -{"pcdb_id": 18718, "brand_name": "Ideal", "model_name": "VOGUE MAX SYSTEM", "model_qualifier": "18IE", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 18.0, "final_year_of_manufacture": null, "raw": ["018718", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "VOGUE MAX SYSTEM", "18IE", "41-750-58", "2020", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18.0", "18.0", "", "", "88.6", "79.6", "", "58.1", "", "2", "", "", "102", "1", "2", "40", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "89.5", "97.7", "", "", "", "", "96.1"]} -{"pcdb_id": 18719, "brand_name": "Ideal", "model_name": "VOGUE MAX SYSTEM", "model_qualifier": "18P IE", "winter_efficiency_pct": 89.6, "summer_efficiency_pct": 80.6, "comparative_hot_water_efficiency_pct": 58.9, "output_kw_max": 18.0, "final_year_of_manufacture": null, "raw": ["018719", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "VOGUE MAX SYSTEM", "18P IE", "41-750-58", "2020", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "18.0", "18.0", "", "", "89.6", "80.6", "", "58.9", "", "2", "1", "", "102", "1", "2", "40", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "91.5", "99.8", "", "", "", "", "98.2"]} -{"pcdb_id": 18720, "brand_name": "Ideal", "model_name": "VOGUE MAX SYSTEM", "model_qualifier": "26IE", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 26.0, "final_year_of_manufacture": null, "raw": ["018720", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "VOGUE MAX SYSTEM", "26IE", "41-750-59", "2020", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "26.0", "26.0", "", "", "88.5", "79.5", "", "58.1", "", "2", "1", "", "102", "1", "2", "45", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "89.6", "97.5", "", "", "", "", "96.0"]} -{"pcdb_id": 18721, "brand_name": "Ideal", "model_name": "VOGUE MAX SYSTEM", "model_qualifier": "26P IE", "winter_efficiency_pct": 89.5, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 58.8, "output_kw_max": 26.0, "final_year_of_manufacture": null, "raw": ["018721", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "VOGUE MAX SYSTEM", "26P IE", "", "2020", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "26.0", "26.0", "", "", "89.5", "80.5", "", "58.8", "", "2", "1", "", "102", "1", "2", "45", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "91.5", "99.7", "", "", "", "", "98.1"]} -{"pcdb_id": 18722, "brand_name": "Ideal", "model_name": "VOGUE MAX SYSTEM", "model_qualifier": "32IE", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 32.0, "final_year_of_manufacture": null, "raw": ["018722", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "VOGUE MAX SYSTEM", "32IE", "41-796-60", "2020", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "32.0", "32.0", "", "", "88.6", "79.6", "", "58.2", "", "2", "", "", "102", "1", "2", "49", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "89.8", "97.7", "", "", "", "", "96.2"]} -{"pcdb_id": 18723, "brand_name": "Ideal", "model_name": "VOGUE MAX SYSTEM", "model_qualifier": "32P IE", "winter_efficiency_pct": 89.7, "summer_efficiency_pct": 80.7, "comparative_hot_water_efficiency_pct": 58.9, "output_kw_max": 32.0, "final_year_of_manufacture": null, "raw": ["018723", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "VOGUE MAX SYSTEM", "32P IE", "41-796-60", "2020", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "32.0", "32.0", "", "", "89.7", "80.7", "", "58.9", "", "2", "1", "", "102", "1", "2", "49", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "91.8", "99.8", "", "", "", "", "98.3"]} -{"pcdb_id": 18724, "brand_name": "Vokera BY RIELLO", "model_name": "Easi-Heat Plus", "model_qualifier": "32Ci", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 56.1, "output_kw_max": 24.5, "final_year_of_manufacture": null, "raw": ["018724", "000011", "0", "2020/Oct/15 09:59", "Vokera", "Vokera BY RIELLO", "Easi-Heat Plus", "32Ci", "20158336", "2019", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.5", "24.5", "", "", "88.4", "79.8", "", "56.1", "", "2", "", "", "104", "1", "2", "38", "5.6", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "88.1", "97.7", "", "", "", "", "95.9"]} -{"pcdb_id": 18725, "brand_name": "Vokera BY RIELLO", "model_name": "Compact", "model_qualifier": "32A", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 56.1, "output_kw_max": 24.5, "final_year_of_manufacture": null, "raw": ["018725", "000011", "0", "2020/Oct/15 09:56", "Vokera", "Vokera BY RIELLO", "Compact", "32A", "20166153", "2018", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.5", "24.5", "", "", "88.4", "79.8", "", "56.1", "", "2", "", "", "104", "1", "2", "38", "2.4", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "88.1", "97.7", "", "", "", "", "95.9"]} -{"pcdb_id": 18726, "brand_name": "Alpha", "model_name": "E-Tec", "model_qualifier": "15R", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 15.4, "final_year_of_manufacture": null, "raw": ["018726", "000001", "0", "2019/Dec/16 15:48", "Alpha Therm", "Alpha", "E-Tec", "15R", "3.028463", "2019", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "15.4", "15.4", "", "", "88.2", "79.2", "", "57.9", "", "2", "", "", "102", "1", "2", "23", "7", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "1005", "", "", "", "", "", "", "", "", "88.1", "97.3", "", "", "", "", "95.6"]} -{"pcdb_id": 18727, "brand_name": "Alpha", "model_name": "E-Tec", "model_qualifier": "15R", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 15.4, "final_year_of_manufacture": null, "raw": ["018727", "000001", "0", "2019/Dec/16 15:48", "Alpha Therm", "Alpha", "E-Tec", "15R", "3.028463GPL", "2019", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "15.4", "15.4", "", "", "89.2", "80.2", "", "58.6", "", "2", "1", "", "102", "1", "2", "23", "7", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "1005", "", "", "", "", "", "", "", "", "90.1", "99.5", "", "", "", "", "97.7"]} -{"pcdb_id": 18728, "brand_name": "Alpha", "model_name": "E-Tec", "model_qualifier": "20R", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 20.5, "final_year_of_manufacture": null, "raw": ["018728", "000001", "0", "2019/Dec/16 15:48", "Alpha Therm", "Alpha", "E-Tec", "20R", "3.028464", "2019", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "20.5", "20.5", "", "", "88.3", "79.3", "", "57.9", "", "2", "", "", "102", "1", "2", "32", "7", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "1005", "", "", "", "", "", "", "", "", "87.7", "97.6", "", "", "", "", "95.7"]} -{"pcdb_id": 18729, "brand_name": "Alpha", "model_name": "E-Tec", "model_qualifier": "20R", "winter_efficiency_pct": 89.3, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 20.5, "final_year_of_manufacture": null, "raw": ["018729", "000001", "0", "2019/Dec/16 15:48", "Alpha Therm", "Alpha", "E-Tec", "20R", "3.028464GPL", "2019", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "20.5", "20.5", "", "", "89.3", "80.3", "", "58.6", "", "2", "1", "", "102", "1", "2", "32", "7", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "1005", "", "", "", "", "", "", "", "", "89.6", "99.7", "", "", "", "", "97.8"]} -{"pcdb_id": 18731, "brand_name": "Lukey", "model_name": "28 HE", "model_qualifier": "", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 88.2, "comparative_hot_water_efficiency_pct": 76.5, "output_kw_max": 17.5, "final_year_of_manufacture": null, "raw": ["018731", "000314", "0", "2020/Aug/17 15:54", "Lukey Cassette Boilers (UK)", "Lukey", "28 HE", "", "", "2018", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "17.5", "17.5", "", "", "89.0", "88.2", "", "76.5", "", "2", "", "", "104", "1", "2", "20.6", "2", "0", "", "", "", "0", "", "", "", "", "2", "6.884", "0.074", "0.008", "0.72973", "12.627", "0.1", "0.003", "0.7123", "0.00005", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "99.3", "", "", "", "", "97.1"]} -{"pcdb_id": 18732, "brand_name": "Lukey", "model_name": "28 HE", "model_qualifier": "", "winter_efficiency_pct": 90.0, "summer_efficiency_pct": 81.4, "comparative_hot_water_efficiency_pct": 57.2, "output_kw_max": 17.5, "final_year_of_manufacture": null, "raw": ["018732", "000314", "0", "2020/Aug/17 15:53", "Lukey Cassette Boilers (UK)", "Lukey", "28 HE", "", "", "2018", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "17.5", "17.5", "", "", "90.0", "81.4", "", "57.2", "", "2", "1", "", "104", "1", "2", "20.6", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.9", "101.5", "", "", "", "", "99.3"]} -{"pcdb_id": 18733, "brand_name": "Vokera BY RIELLO", "model_name": "Easi-Heat Plus", "model_qualifier": "25Ci", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 56.2, "output_kw_max": 19.5, "final_year_of_manufacture": null, "raw": ["018733", "000011", "0", "2020/Aug/13 07:53", "Vokera", "Vokera BY RIELLO", "Easi-Heat Plus", "25Ci", "20158332", "2019", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "19.5", "19.5", "", "", "88.5", "79.9", "", "56.2", "", "2", "", "", "104", "1", "2", "29", "5.6", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "98.1", "", "", "", "", "96.2"]} -{"pcdb_id": 18734, "brand_name": "Vokera BY RIELLO", "model_name": "Easi-Heat Plus", "model_qualifier": "29Ci", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 56.1, "output_kw_max": 24.5, "final_year_of_manufacture": null, "raw": ["018734", "000011", "0", "2020/Aug/13 07:54", "Vokera", "Vokera BY RIELLO", "Easi-Heat Plus", "29Ci", "20158334", "2019", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.5", "24.5", "", "", "88.4", "79.8", "", "56.1", "", "2", "", "", "104", "1", "2", "38.0", "5.6", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.1", "97.7", "", "", "", "", "95.9"]} -{"pcdb_id": 18736, "brand_name": "Baxi", "model_name": "ASSURE", "model_qualifier": "25 COMBI", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 86.7, "comparative_hot_water_efficiency_pct": 80.2, "output_kw_max": 20.0, "final_year_of_manufacture": null, "raw": ["018736", "000005", "0", "2020/Mar/09 09:05", "Baxi Heating", "Baxi", "ASSURE", "25 COMBI", "47-077-42", "2020", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "20.0", "20.0", "", "", "88.4", "86.7", "", "80.2", "", "2", "", "", "104", "1", "2", " 28", " 3", "0", "", "", "", "0", "", "", "", "", "1", "6.563", "0.102", "0.0005", "0.46696", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "88.0", "97.8", "", "", "", "", "95.9"]} -{"pcdb_id": 18737, "brand_name": "Baxi", "model_name": "ASSURE", "model_qualifier": "30 COMBI", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 86.7, "comparative_hot_water_efficiency_pct": 79.3, "output_kw_max": 25.0, "final_year_of_manufacture": null, "raw": ["018737", "000005", "0", "2020/Mar/09 13:00", "Baxi Heating", "Baxi", "ASSURE", "30 COMBI", "47-077-43", "2020", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "25.0", "25.0", "", "", "88.4", "86.7", "", "79.3", "", "2", "", "", "104", "1", "2", " 38", " 3", "0", "", "", "", "0", "", "", "", "", "1", "6.641", "0.105", "0.001", "0.54126", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "88.1", "97.8", "", "", "", "", "96.0"]} -{"pcdb_id": 18738, "brand_name": "Baxi", "model_name": "ASSURE", "model_qualifier": "36 COMBI", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 86.7, "comparative_hot_water_efficiency_pct": 81.4, "output_kw_max": 25.0, "final_year_of_manufacture": null, "raw": ["018738", "000005", "0", "2020/Mar/09 09:05", "Baxi Heating", "Baxi", "ASSURE", "36 COMBI", "47-077-44", "2020", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "25.0", "25.0", "", "", "88.4", "86.7", "", "81.4", "", "2", "", "", "104", "1", "2", " 72", "3", "0", "", "", "", "0", "", "", "", "", "1", "6.47", "0.102", "0.0015", "0.37374", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "88.1", "97.8", "", "", "", "", "96.0"]} -{"pcdb_id": 18739, "brand_name": "Baxi", "model_name": "ASSURE", "model_qualifier": "25 COMBI LPG", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 88.6, "comparative_hot_water_efficiency_pct": 80.0, "output_kw_max": 20.0, "final_year_of_manufacture": null, "raw": ["018739", "000005", "0", "2020/Mar/09 09:05", "Baxi Heating", "Baxi", "ASSURE", "25 COMBI LPG", "47-077-45", "2020", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "20.0", "20.0", "", "", "89.4", "88.6", "", "80.0", "", "2", "1", "", "104", "1", "2", " 28", " 3", "0", "", "", "", "0", "", "", "", "", "1", "6.725", "0.104", "0.002", "0.61406", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "90.0", "99.9", "", "", "", "", "98.0"]} -{"pcdb_id": 18740, "brand_name": "Baxi", "model_name": "ASSURE", "model_qualifier": "30 COMBI LPG", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 88.6, "comparative_hot_water_efficiency_pct": 80.1, "output_kw_max": 25.0, "final_year_of_manufacture": null, "raw": ["018740", "000005", "0", "2020/Mar/09 13:00", "Baxi Heating", "Baxi", "ASSURE", "30 COMBI LPG", "47-077-46", "2020", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "25.0", "25.0", "", "", "89.4", "88.6", "", "80.1", "", "2", "1", "", "104", "1", "2", "38", "3", "0", "", "", "", "0", "", "", "", "", "1", "6.717", "0.103", "0.0015", "0.60929", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "90.0", "99.9", "", "", "", "", "98.0"]} -{"pcdb_id": 18741, "brand_name": "Baxi", "model_name": "ASSURE", "model_qualifier": "36 COMBI LPG", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 88.6, "comparative_hot_water_efficiency_pct": 79.8, "output_kw_max": 25.0, "final_year_of_manufacture": null, "raw": ["018741", "000005", "0", "2020/Mar/09 09:15", "Baxi Heating", "Baxi", "ASSURE", "36 COMBI LPG", "47-077-47", "2020", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "25.0", "25.0", "", "", "89.4", "88.6", "", "79.8", "", "2", "1", "", "104", "1", "2", "72", "3", "0", "", "", "", "0", "", "", "", "", "1", "6.748", "0.102", "0.0015", "0.64132", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "90.1", "100.0", "", "", "", "", "98.1"]} -{"pcdb_id": 18742, "brand_name": "Baxi", "model_name": "ASSURE", "model_qualifier": "12 SYSTEM", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 12.0, "final_year_of_manufacture": null, "raw": ["018742", "000005", "0", "2020/Mar/09 09:42", "Baxi Heating", "Baxi", "ASSURE", "12 SYSTEM", "41-470-85", "2020", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "12.0", "12.0", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", " 20", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "88.2", "97.8", "", "", "", "", "96.0"]} -{"pcdb_id": 18743, "brand_name": "Baxi", "model_name": "ASSURE", "model_qualifier": "15 SYSTEM", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 15.0, "final_year_of_manufacture": null, "raw": ["018743", "000005", "0", "2020/Mar/09 09:43", "Baxi Heating", "Baxi", "ASSURE", "15 SYSTEM", "41-470-86", "2020", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "15.0", "15.0", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "25", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "88.2", "97.8", "", "", "", "", "95.9"]} -{"pcdb_id": 18744, "brand_name": "Baxi", "model_name": "ASSURE", "model_qualifier": "18 SYSTEM", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 18.0, "final_year_of_manufacture": null, "raw": ["018744", "000005", "0", "2020/Mar/09 09:43", "Baxi Heating", "Baxi", "ASSURE", "18 SYSTEM", "41-479-87", "2020", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18.0", "18.0", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "30", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "88.2", "97.8", "", "", "", "", "96.0"]} -{"pcdb_id": 18745, "brand_name": "Baxi", "model_name": "ASSURE", "model_qualifier": "24 SYSTEM", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 24.0, "final_year_of_manufacture": null, "raw": ["018745", "000005", "0", "2020/Mar/09 09:43", "Baxi Heating", "Baxi", "ASSURE", "24 SYSTEM", "41-470-88", "2020", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24.0", "24.0", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "60", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "88.0", "97.8", "", "", "", "", "95.9"]} -{"pcdb_id": 18746, "brand_name": "Baxi", "model_name": "ASSURE", "model_qualifier": "18 SYSTEM LPG", "winter_efficiency_pct": 89.5, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 58.8, "output_kw_max": 18.0, "final_year_of_manufacture": null, "raw": ["018746", "000005", "0", "2020/Mar/09 09:44", "Baxi Heating", "Baxi", "ASSURE", "18 SYSTEM LPG", "41-479-92", "2020", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "18.0", "18.0", "", "", "89.5", "80.5", "", "58.8", "", "2", "1", "", "102", "1", "2", "30", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "90.2", "100.0", "", "", "", "", "98.1"]} -{"pcdb_id": 18747, "brand_name": "Baxi", "model_name": "ASSURE", "model_qualifier": "24 SYSTEM LPG", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 80.4, "comparative_hot_water_efficiency_pct": 58.7, "output_kw_max": 24.0, "final_year_of_manufacture": null, "raw": ["018747", "000005", "0", "2020/Mar/09 09:44", "Baxi Heating", "Baxi", "ASSURE", "24 SYSTEM LPG", "41-470-93", "2020", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "24.0", "24.0", "", "", "89.4", "80.4", "", "58.7", "", "2", "1", "", "102", "1", "2", "60", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "90.0", "99.9", "", "", "", "", "98.0"]} -{"pcdb_id": 18748, "brand_name": "Baxi", "model_name": "ASSURE", "model_qualifier": "13 HEAT", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 13.0, "final_year_of_manufacture": null, "raw": ["018748", "000005", "0", "2020/Jun/01 12:11", "Baxi Heating", "Baxi", "ASSURE", "13 HEAT", "41-470-80", "2020", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "13.0", "13.0", "", "", "88.6", "79.6", "", "58.2", "", "2", "", "", "102", "1", "2", "17", " 0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "98.4", "", "", "", "", "96.4"]} -{"pcdb_id": 18749, "brand_name": "Baxi", "model_name": "ASSURE", "model_qualifier": "16 HEAT", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 16.0, "final_year_of_manufacture": null, "raw": ["018749", "000005", "0", "2020/Jun/01 12:12", "Baxi Heating", "Baxi", "ASSURE", "16 HEAT", "41-470-81", "2020", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "16.0", "16.0", "", "", "88.6", "79.6", "", "58.2", "", "2", "", "", "102", "1", "2", "20", " 0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "98.4", "", "", "", "", "96.4"]} -{"pcdb_id": 18750, "brand_name": "Baxi", "model_name": "ASSURE", "model_qualifier": "19 HEAT", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 19.0, "final_year_of_manufacture": null, "raw": ["018750", "000005", "0", "2020/Jun/01 12:12", "Baxi Heating", "Baxi", "ASSURE", "19 HEAT", "41-470-82", "2020", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "19.0", "19.0", "", "", "88.6", "79.6", "", "58.2", "", "2", "", "", "102", "1", "2", "23", " 0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "98.4", "", "", "", "", "96.4"]} -{"pcdb_id": 18751, "brand_name": "Baxi", "model_name": "ASSURE", "model_qualifier": "25 HEAT", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 25.0, "final_year_of_manufacture": null, "raw": ["018751", "000005", "0", "2020/Jun/01 12:22", "Baxi Heating", "Baxi", "ASSURE", "25 HEAT", "41-470-83", "2020", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "25.0", "25.0", "", "", "88.6", "79.6", "", "58.2", "", "2", "", "", "102", "1", "2", "33", " 0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "98.4", "", "", "", "", "96.4"]} -{"pcdb_id": 18752, "brand_name": "Baxi", "model_name": "ASSURE", "model_qualifier": "30 HEAT", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 30.0, "final_year_of_manufacture": null, "raw": ["018752", "000005", "0", "2020/Mar/19 14:39", "Baxi Heating", "Baxi", "ASSURE", "30 HEAT", "41-470-84", "2020", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "30.0", "30.0", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "44", " 0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.3", "98.0", "", "", "", "", "96.0"]} -{"pcdb_id": 18753, "brand_name": "Baxi", "model_name": "613 HEAT", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 13.0, "final_year_of_manufacture": null, "raw": ["018753", "000005", "0", "2020/Jun/01 12:23", "Baxi Heating", "Baxi", "613 HEAT", "", "41-470-66", "2020", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "13.0", "13.0", "", "", "88.6", "79.6", "", "58.2", "", "2", "", "", "102", "1", "2", "17", " 0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "98.4", "", "", "", "", "96.4"]} -{"pcdb_id": 18754, "brand_name": "Baxi", "model_name": "616 HEAT", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 16.0, "final_year_of_manufacture": null, "raw": ["018754", "000005", "0", "2020/Jun/01 12:24", "Baxi Heating", "Baxi", "616 HEAT", "", "41-470-67", "2020", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "16.0", "16.0", "", "", "88.6", "79.6", "", "58.2", "", "2", "", "", "102", "1", "2", "20", " 0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "98.4", "", "", "", "", "96.4"]} -{"pcdb_id": 18755, "brand_name": "Baxi", "model_name": "619 HEAT", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 19.0, "final_year_of_manufacture": null, "raw": ["018755", "000005", "0", "2020/Jun/01 12:26", "Baxi Heating", "Baxi", "619 HEAT", "", "41-470-68", "2020", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "19.0", "19.0", "", "", "88.6", "79.6", "", "58.2", "", "2", "", "", "102", "1", "2", "23", " 0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "98.4", "", "", "", "", "96.4"]} -{"pcdb_id": 18756, "brand_name": "Baxi", "model_name": "625 HEAT", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 25.0, "final_year_of_manufacture": null, "raw": ["018756", "000005", "0", "2020/Jun/01 12:26", "Baxi Heating", "Baxi", "625 HEAT", "", "41-470-69", "2020", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "25.0", "25.0", "", "", "88.6", "79.6", "", "58.2", "", "2", "", "", "102", "1", "2", "33", " 0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "98.4", "", "", "", "", "96.4"]} -{"pcdb_id": 18757, "brand_name": "Baxi", "model_name": "630 HEAT", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 30.0, "final_year_of_manufacture": null, "raw": ["018757", "000005", "0", "2020/Mar/19 14:36", "Baxi Heating", "Baxi", "630 HEAT", "", "41-470-70", "2020", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "30.0", "30.0", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "44", " 0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.3", "98.0", "", "", "", "", "96.0"]} -{"pcdb_id": 18758, "brand_name": "Ideal", "model_name": "INSTINCT2", "model_qualifier": "24", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 70.0, "output_kw_max": 24.2, "final_year_of_manufacture": null, "raw": ["018758", "000008", "0", "2020/Sep/22 17:49", "Ideal Boilers", "Ideal", "INSTINCT2", "24", "47-349-68", "2019", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "89.0", "87.3", "", "70.0", "", "2", "", "", "104", "1", "2", "42", "3", "0", "", "", "", "0", "", "", "", "", "1", "7.526", "0.12", "0.0027", "1.43483", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.0", "98.6", "", "", "", "", "96.9"]} -{"pcdb_id": 18759, "brand_name": "Ideal", "model_name": "INSTINCT2", "model_qualifier": "30", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 69.5, "output_kw_max": 24.2, "final_year_of_manufacture": null, "raw": ["018759", "000008", "0", "2020/Sep/22 18:01", "Ideal Boilers", "Ideal", "INSTINCT2", "30", "47-349-69", "2019", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "89.0", "87.3", "", "69.5", "", "2", "", "", "104", "1", "2", "32", "3", "0", "", "", "", "0", "", "", "", "", "1", "7.576", "0.119", "0.0027", "1.48359", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.0", "98.6", "", "", "", "", "96.9"]} -{"pcdb_id": 18760, "brand_name": "Ideal", "model_name": "INSTINCT2", "model_qualifier": "35", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 70.3, "output_kw_max": 24.2, "final_year_of_manufacture": null, "raw": ["018760", "000008", "0", "2020/Sep/22 18:02", "Ideal Boilers", "Ideal", "INSTINCT2", "35", "47-349-70", "2019", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "89.0", "87.3", "", "70.3", "", "2", "", "", "104", "1", "2", "29", "3", "0", "", "", "", "0", "", "", "", "", "1", "7.495", "0.119", "0.0026", "1.40519", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.0", "98.6", "", "", "", "", "96.9"]} -{"pcdb_id": 18761, "brand_name": "Ideal", "model_name": "ATLANTIC COMBI", "model_qualifier": "24", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 67.3, "output_kw_max": 24.2, "final_year_of_manufacture": null, "raw": ["018761", "000008", "0", "2020/Sep/22 18:02", "Ideal Boilers", "Ideal", "ATLANTIC COMBI", "24", "47-349-81", "2019", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "89.0", "87.3", "", "67.3", "", "2", "", "", "104", "1", "2", "42", "3", "0", "", "", "", "0", "", "", "", "", "1", "7.821", "0.119", "0.0027", "1.7208", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.0", "98.6", "", "", "", "", "96.9"]} -{"pcdb_id": 18762, "brand_name": "Ideal", "model_name": "ATLANTIC COMBI", "model_qualifier": "30", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 69.5, "output_kw_max": 24.2, "final_year_of_manufacture": null, "raw": ["018762", "000008", "0", "2020/Sep/22 18:02", "Ideal Boilers", "Ideal", "ATLANTIC COMBI", "30", "47-349-82", "2019", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "89.0", "87.3", "", "69.5", "", "2", "", "", "104", "1", "2", "32", "3", "0", "", "", "", "0", "", "", "", "", "1", "7.576", "0.119", "0.0027", "1.48359", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.0", "98.6", "", "", "", "", "96.9"]} -{"pcdb_id": 18763, "brand_name": "Ideal", "model_name": "ATLANTIC COMBI", "model_qualifier": "35", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 70.3, "output_kw_max": 24.2, "final_year_of_manufacture": null, "raw": ["018763", "000008", "0", "2020/Sep/22 18:03", "Ideal Boilers", "Ideal", "ATLANTIC COMBI", "35", "47-349-83", "2019", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "89.0", "87.3", "", "70.3", "", "2", "", "", "104", "1", "2", "29", "3", "0", "", "", "", "0", "", "", "", "", "1", "7.495", "0.119", "0.0026", "1.40519", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.0", "98.6", "", "", "", "", "96.9"]} -{"pcdb_id": 18764, "brand_name": "Ideal", "model_name": "CLASSIC2", "model_qualifier": "24", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 70.0, "output_kw_max": 24.2, "final_year_of_manufacture": null, "raw": ["018764", "000008", "0", "2020/Sep/22 18:03", "Ideal Boilers", "Ideal", "CLASSIC2", "24", "47-349-71", "2019", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "89.0", "87.3", "", "70.0", "", "2", "", "", "104", "1", "2", "42", "3", "0", "", "", "", "0", "", "", "", "", "1", "7.526", "0.12", "0.0027", "1.43483", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.0", "98.6", "", "", "", "", "96.9"]} -{"pcdb_id": 18765, "brand_name": "Ideal", "model_name": "CLASSIC2", "model_qualifier": "30", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 69.5, "output_kw_max": 24.2, "final_year_of_manufacture": null, "raw": ["018765", "000008", "0", "2020/Sep/22 18:03", "Ideal Boilers", "Ideal", "CLASSIC2", "30", "47-349-72", "2019", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "89.0", "87.3", "", "69.5", "", "2", "", "", "104", "1", "2", "32", "3", "0", "", "", "", "0", "", "", "", "", "1", "7.576", "1.119", "0.0027", "1.48359", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.0", "98.6", "", "", "", "", "96.9"]} -{"pcdb_id": 18766, "brand_name": "Ideal", "model_name": "CLASSIC2", "model_qualifier": "35", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 70.3, "output_kw_max": 24.2, "final_year_of_manufacture": null, "raw": ["018766", "000008", "0", "2020/Sep/22 18:03", "Ideal Boilers", "Ideal", "CLASSIC2", "35", "47-349-73", "2019", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "89.0", "87.3", "", "70.3", "", "2", "", "", "104", "1", "2", "29", "3", "0", "", "", "", "0", "", "", "", "", "1", "7.495", "0.119", "0.0026", "1.40519", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.0", "98.6", "", "", "", "", "96.9"]} -{"pcdb_id": 18767, "brand_name": "Ideal", "model_name": "ESPRIT ECO2", "model_qualifier": "24", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 70.0, "output_kw_max": 24.2, "final_year_of_manufacture": null, "raw": ["018767", "000008", "0", "2020/Sep/22 18:03", "Ideal Boilers", "Ideal", "ESPRIT ECO2", "24", "47-349-65", "2019", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "89.0", "87.3", "", "70.0", "", "2", "", "", "104", "1", "2", "29", "3", "0", "", "", "", "0", "", "", "", "", "1", "7.526", "0.12", "0.0027", "1.43483", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.0", "98.6", "", "", "", "", "96.9"]} -{"pcdb_id": 18768, "brand_name": "Ideal", "model_name": "ESPRIT ECO2", "model_qualifier": "30", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 69.5, "output_kw_max": 24.2, "final_year_of_manufacture": null, "raw": ["018768", "000008", "0", "2020/Sep/22 18:03", "Ideal Boilers", "Ideal", "ESPRIT ECO2", "30", "47-349-66", "2019", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "89.0", "87.3", "", "69.5", "", "2", "", "", "104", "1", "2", "32", "3", "0", "", "", "", "0", "", "", "", "", "1", "7.576", "0.119", "0.0027", "1.48359", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.0", "98.6", "", "", "", "", "96.9"]} -{"pcdb_id": 18769, "brand_name": "Ideal", "model_name": "ESPRIT ECO2", "model_qualifier": "35", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 70.3, "output_kw_max": 24.2, "final_year_of_manufacture": null, "raw": ["018769", "000008", "0", "2020/Sep/22 18:03", "Ideal Boilers", "Ideal", "ESPRIT ECO2", "35", "47-349-67", "2019", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "89.0", "87.3", "", "70.3", "", "2", "", "", "104", "1", "2", "29", "3", "0", "", "", "", "0", "", "", "", "", "1", "7.495", "0.119", "0.0026", "1.40519", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.0", "98.6", "", "", "", "", "96.9"]} -{"pcdb_id": 18770, "brand_name": "Ideal", "model_name": "I2 COMBI", "model_qualifier": "24", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 70.0, "output_kw_max": 24.2, "final_year_of_manufacture": null, "raw": ["018770", "000008", "0", "2020/Sep/22 18:03", "Ideal Boilers", "Ideal", "I2 COMBI", "24", "47-349-74", "2019", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "89.0", "87.3", "", "70.0", "", "2", "", "", "104", "1", "2", "42", "3", "0", "", "", "", "0", "", "", "", "", "1", "7.526", "0.12", "0.0027", "1.43483", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.0", "98.6", "", "", "", "", "96.9"]} -{"pcdb_id": 18771, "brand_name": "Ideal", "model_name": "I2 COMBI", "model_qualifier": "30", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 69.5, "output_kw_max": 24.2, "final_year_of_manufacture": null, "raw": ["018771", "000008", "0", "2020/Sep/22 18:03", "Ideal Boilers", "Ideal", "I2 COMBI", "30", "47-349-75", "2019", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "89.0", "87.3", "", "69.5", "", "2", "", "", "104", "1", "2", "32", "3", "0", "", "", "", "0", "", "", "", "", "1", "7.576", "0.119", "0.0027", "1.48359", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.0", "98.6", "", "", "", "", "96.9"]} -{"pcdb_id": 18772, "brand_name": "Ideal", "model_name": "I2 COMBI", "model_qualifier": "35", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 70.3, "output_kw_max": 24.2, "final_year_of_manufacture": null, "raw": ["018772", "000008", "0", "2020/Sep/22 18:03", "Ideal Boilers", "Ideal", "I2 COMBI", "35", "47-349-76", "2019", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "89.0", "87.3", "", "70.3", "", "2", "", "", "104", "1", "2", "29", "3", "0", "", "", "", "0", "", "", "", "", "1", "7.495", "0.119", "0.0026", "1.40519", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.0", "98.6", "", "", "", "", "96.9"]} -{"pcdb_id": 18773, "brand_name": "Ideal", "model_name": "EXCLUSIVE2", "model_qualifier": "24", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 70.0, "output_kw_max": 24.2, "final_year_of_manufacture": null, "raw": ["018773", "000008", "0", "2020/Sep/22 18:04", "Ideal Boilers", "Ideal", "EXCLUSIVE2", "24", "47-349-62", "2019", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "89.0", "87.3", "", "70.0", "", "2", "", "", "104", "1", "2", "42", "3", "0", "", "", "", "0", "", "", "", "", "1", "7.526", "0.12", "0.0027", "1.43483", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.0", "98.6", "", "", "", "", "96.9"]} -{"pcdb_id": 18774, "brand_name": "Ideal", "model_name": "EXCLUSIVE2", "model_qualifier": "30", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 69.5, "output_kw_max": 24.2, "final_year_of_manufacture": null, "raw": ["018774", "000008", "0", "2020/Sep/22 18:04", "Ideal Boilers", "Ideal", "EXCLUSIVE2", "30", "47-349-63", "2019", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "89.0", "87.3", "", "69.5", "", "2", "", "", "104", "1", "2", "32", "3", "0", "", "", "", "0", "", "", "", "", "1", "7.576", "0.119", "0.0027", "1.48359", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.0", "98.6", "", "", "", "", "96.9"]} -{"pcdb_id": 18775, "brand_name": "Ideal", "model_name": "EXCLUSIVE2", "model_qualifier": "35", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 70.3, "output_kw_max": 24.2, "final_year_of_manufacture": null, "raw": ["018775", "000008", "0", "2020/Sep/22 18:04", "Ideal Boilers", "Ideal", "EXCLUSIVE2", "35", "47-349-64", "2019", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "89.0", "87.3", "", "70.3", "", "2", "", "", "104", "1", "2", "29", "3", "0", "", "", "", "0", "", "", "", "", "1", "7.495", "0.119", "0.0026", "1.40519", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.0", "98.6", "", "", "", "", "96.9"]} -{"pcdb_id": 18776, "brand_name": "Ideal", "model_name": "SERIES III GB", "model_qualifier": "24 PROPANE", "winter_efficiency_pct": 90.1, "summer_efficiency_pct": 89.3, "comparative_hot_water_efficiency_pct": 67.8, "output_kw_max": 24.2, "final_year_of_manufacture": null, "raw": ["018776", "000008", "0", "2020/Sep/22 18:04", "Ideal Boilers", "Ideal", "SERIES III GB", "24 PROPANE", "", "2019", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "90.1", "89.3", "", "67.8", "", "2", "1", "", "104", "1", "2", "25", "3", "0", "", "", "", "0", "", "", "", "", "1", "7.937", "0.121", "0.0031", "1.83121", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "92.0", "100.8", "", "", "", "", "99.1"]} -{"pcdb_id": 18777, "brand_name": "Ideal", "model_name": "SERIES III GB", "model_qualifier": "30 PROPANE", "winter_efficiency_pct": 90.1, "summer_efficiency_pct": 89.3, "comparative_hot_water_efficiency_pct": 69.4, "output_kw_max": 24.2, "final_year_of_manufacture": null, "raw": ["018777", "000008", "0", "2020/Sep/22 18:04", "Ideal Boilers", "Ideal", "SERIES III GB", "30 PROPANE", "", "2019", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "90.1", "89.3", "", "69.4", "", "2", "1", "", "104", "1", "2", "24", "3", "0", "", "", "", "0", "", "", "", "", "1", "7.758", "0.119", "0.003", "1.65818", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "92.0", "100.8", "", "", "", "", "99.1"]} -{"pcdb_id": 18778, "brand_name": "Morco", "model_name": "SERIES III GB", "model_qualifier": "24NG", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 70.0, "output_kw_max": 24.2, "final_year_of_manufacture": null, "raw": ["018778", "000008", "0", "2020/Sep/22 18:04", "Ideal Boilers", "Morco", "SERIES III GB", "24NG", "", "2019", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "89.0", "87.3", "", "70.0", "", "2", "", "", "104", "1", "2", "42", "3", "0", "", "", "", "0", "", "", "", "", "1", "7.526", "0.12", "0.0027", "1.43483", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.0", "98.6", "", "", "", "", "96.9"]} -{"pcdb_id": 18779, "brand_name": "Morco", "model_name": "SERIES III GB", "model_qualifier": "30NG", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 69.5, "output_kw_max": 24.2, "final_year_of_manufacture": null, "raw": ["018779", "000008", "0", "2020/Sep/22 18:04", "Ideal Boilers", "Morco", "SERIES III GB", "30NG", "", "2019", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "89.0", "87.3", "", "69.5", "", "2", "", "", "104", "1", "2", "32", "3", "0", "", "", "", "0", "", "", "", "", "1", "7.576", "0.119", "0.0027", "1.48359", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.0", "98.6", "", "", "", "", "96.9"]} -{"pcdb_id": 18780, "brand_name": "Morco", "model_name": "SERIES III GB", "model_qualifier": "24 PROPANE", "winter_efficiency_pct": 90.1, "summer_efficiency_pct": 89.3, "comparative_hot_water_efficiency_pct": 67.8, "output_kw_max": 24.2, "final_year_of_manufacture": null, "raw": ["018780", "000008", "0", "2020/Sep/22 18:04", "Ideal Boilers", "Morco", "SERIES III GB", "24 PROPANE", "", "2019", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "90.1", "89.3", "", "67.8", "", "2", "1", "", "104", "1", "2", "25", "3", "0", "", "", "", "0", "", "", "", "", "1", "7.937", "0.121", "0.0031", "1.83121", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "92.0", "100.8", "", "", "", "", "99.1"]} -{"pcdb_id": 18781, "brand_name": "Morco", "model_name": "SERIES III GB", "model_qualifier": "30 PROPANE", "winter_efficiency_pct": 90.1, "summer_efficiency_pct": 89.3, "comparative_hot_water_efficiency_pct": 69.4, "output_kw_max": 24.2, "final_year_of_manufacture": null, "raw": ["018781", "000008", "0", "2020/Sep/22 18:04", "Ideal Boilers", "Morco", "SERIES III GB", "30 PROPANE", "", "2019", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "90.1", "89.3", "", "69.4", "", "2", "1", "", "104", "1", "2", "24", "3", "0", "", "", "", "0", "", "", "", "", "1", "7.758", "0.119", "0.003", "1.65818", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "92.0", "100.8", "", "", "", "", "99.1"]} -{"pcdb_id": 18782, "brand_name": "Baxi", "model_name": "636 COMBI LPG", "model_qualifier": "", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 88.6, "comparative_hot_water_efficiency_pct": 79.8, "output_kw_max": 25.0, "final_year_of_manufacture": null, "raw": ["018782", "000005", "0", "2020/Apr/15 09:20", "Baxi Heating", "Baxi", "636 COMBI LPG", "", "47-077-31", "2020", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "25.0", "25.0", "", "", "89.4", "88.6", "", "79.8", "", "2", "1", "", "104", "1", "2", "72", "3", "0", "", "", "", "0", "", "", "", "", "1", "6.748", "0.102", "0.0015", "0.64132", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "90.1", "100.0", "", "", "", "", "98.1"]} -{"pcdb_id": 18783, "brand_name": "Worcester", "model_name": "Greenstar 8000 Life", "model_qualifier": "GR8300iW 30 C LPG", "winter_efficiency_pct": 90.5, "summer_efficiency_pct": 88.9, "comparative_hot_water_efficiency_pct": 74.1, "output_kw_max": 29.5, "final_year_of_manufacture": null, "raw": ["018783", "000035", "0", "2020/Jul/16 18:52", "Bosch Thermotechnology", "Worcester", "Greenstar 8000 Life", "GR8300iW 30 C LPG", "47-800-23", "2018", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "29.5", "29.5", "", "", "90.5", "88.9", "", "74.1", "", "2", "0", "", "104", "1", "2", "67", "1", "0", "", "", "", "0", "", "", "", "", "1", "7.261", "0.112", "0.008", "1.12085", "", "", "", "", "", "", "", "", "8325", "", "", "", "", "", "", "", "", "91.0", "99.7", "", "", "", "", "98.1"]} -{"pcdb_id": 18784, "brand_name": "Worcester", "model_name": "Greenstar 8000 Life", "model_qualifier": "GR8300iW 30 R LPG", "winter_efficiency_pct": 90.5, "summer_efficiency_pct": 81.5, "comparative_hot_water_efficiency_pct": 59.5, "output_kw_max": 29.5, "final_year_of_manufacture": null, "raw": ["018784", "000035", "0", "2020/Apr/15 11:26", "Bosch Thermotechnology", "Worcester", "Greenstar 8000 Life", "GR8300iW 30 R LPG", "41-800-04", "2018", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "29.5", "29.5", "", "", "90.5", "81.5", "", "59.5", "", "2", "0", "", "102", "1", "2", "67", "1", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0305", "", "", "", "", "", "", "", "", "91.0", "99.7", "", "", "", "", "98.1"]} -{"pcdb_id": 18785, "brand_name": "Worcester", "model_name": "Greenstar 8000 Life", "model_qualifier": "GR8300iW 30 S LPG", "winter_efficiency_pct": 90.5, "summer_efficiency_pct": 81.5, "comparative_hot_water_efficiency_pct": 59.5, "output_kw_max": 29.5, "final_year_of_manufacture": null, "raw": ["018785", "000035", "0", "2020/Apr/15 11:26", "Bosch Thermotechnology", "Worcester", "Greenstar 8000 Life", "GR8300iW 30 S LPG", "41-406-93", "2018", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "29.5", "29.5", "", "", "90.5", "81.5", "", "59.5", "", "2", "0", "", "102", "1", "2", "67", "1", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "8325", "", "", "", "", "", "", "", "", "91.0", "99.7", "", "", "", "", "98.1"]} -{"pcdb_id": 18786, "brand_name": "Worcester", "model_name": "Greenstar 8000 Life", "model_qualifier": "GR8300iW 35 C LPG", "winter_efficiency_pct": 90.5, "summer_efficiency_pct": 88.9, "comparative_hot_water_efficiency_pct": 74.9, "output_kw_max": 33.7, "final_year_of_manufacture": null, "raw": ["018786", "000035", "0", "2020/Jul/16 18:54", "Bosch Thermotechnology", "Worcester", "Greenstar 8000 Life", "GR8300iW 35 C LPG", "47-800-22", "2018", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "33.7", "33.7", "", "", "90.5", "88.9", "", "74.9", "", "2", "0", "", "104", "1", "2", "48", "1", "0", "", "", "", "0", "", "", "", "", "1", "7.186", "0.109", "0.011", "1.02853", "", "", "", "", "", "", "", "", "8325", "", "", "", "", "", "", "", "", "90.9", "99.7", "", "", "", "", "98.1"]} -{"pcdb_id": 18787, "brand_name": "Worcester", "model_name": "Greenstar 8000 Life", "model_qualifier": "GR8300iW 35 R LPG", "winter_efficiency_pct": 90.5, "summer_efficiency_pct": 81.5, "comparative_hot_water_efficiency_pct": 59.5, "output_kw_max": 33.7, "final_year_of_manufacture": null, "raw": ["018787", "000035", "0", "2020/Apr/15 11:27", "Bosch Thermotechnology", "Worcester", "Greenstar 8000 Life", "GR8300iW 35 R LPG", "41-800-03", "2018", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "33.7", "33.7", "", "", "90.5", "81.5", "", "59.5", "", "2", "0", "", "102", "1", "2", "48", "1", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0305", "", "", "", "", "", "", "", "", "90.9", "99.7", "", "", "", "", "98.1"]} -{"pcdb_id": 18788, "brand_name": "Worcester", "model_name": "Greenstar 8000 Life", "model_qualifier": "GR8300iW 35 S LPG", "winter_efficiency_pct": 90.5, "summer_efficiency_pct": 81.5, "comparative_hot_water_efficiency_pct": 59.5, "output_kw_max": 33.7, "final_year_of_manufacture": null, "raw": ["018788", "000035", "0", "2020/Aug/11 15:50", "Bosch Thermotechnology", "Worcester", "Greenstar 8000 Life", "GR8300iW 35 S LPG", "41-406-92", "2018", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "33.7", "33.7", "", "", "90.5", "81.5", "", "59.5", "", "2", "0", "", "102", "1", "2", "48", "1", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "8325", "", "", "", "", "", "", "", "", "90.9", "99.7", "", "", "", "", "98.1"]} -{"pcdb_id": 18789, "brand_name": "Worcester", "model_name": "Greenstar 8000 Life", "model_qualifier": "GR8300iW 40 C LPG", "winter_efficiency_pct": 90.4, "summer_efficiency_pct": 88.9, "comparative_hot_water_efficiency_pct": 73.5, "output_kw_max": 33.7, "final_year_of_manufacture": null, "raw": ["018789", "000035", "0", "2020/Jul/16 18:56", "Bosch Thermotechnology", "Worcester", "Greenstar 8000 Life", "GR8300iW 40 C LPG", "47-800-21", "2018", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "33.7", "33.7", "", "", "90.4", "88.9", "", "73.5", "", "2", "0", "", "104", "1", "2", "48", "1", "0", "", "", "", "0", "", "", "", "", "1", "7.323", "0.112", "0.01", "1.16904", "", "", "", "", "", "", "", "", "8325", "", "", "", "", "", "", "", "", "91.0", "99.6", "", "", "", "", "97.9"]} -{"pcdb_id": 18790, "brand_name": "Worcester", "model_name": "Greenstar 8000 Life", "model_qualifier": "GR8300iW 40 R LPG", "winter_efficiency_pct": 90.6, "summer_efficiency_pct": 81.6, "comparative_hot_water_efficiency_pct": 59.6, "output_kw_max": 40.0, "final_year_of_manufacture": null, "raw": ["018790", "000035", "0", "2020/Apr/15 11:27", "Bosch Thermotechnology", "Worcester", "Greenstar 8000 Life", "GR8300iW 40 R LPG", "41-800-02", "2018", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "40.0", "40.0", "", "", "90.6", "81.6", "", "59.6", "", "2", "0", "", "102", "1", "2", "75", "1", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0305", "", "", "", "", "", "", "", "", "91.2", "99.8", "", "", "", "", "98.2"]} -{"pcdb_id": 18791, "brand_name": "Worcester", "model_name": "Greenstar 8000 Life", "model_qualifier": "GR8300iW 45 C LPG", "winter_efficiency_pct": 90.7, "summer_efficiency_pct": 89.1, "comparative_hot_water_efficiency_pct": 72.5, "output_kw_max": 33.7, "final_year_of_manufacture": null, "raw": ["018791", "000035", "0", "2020/Jul/16 18:58", "Bosch Thermotechnology", "Worcester", "Greenstar 8000 Life", "GR8300iW 45 C LPG", "47-800-20", "2018", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "33.7", "33.7", "", "", "90.7", "89.1", "", "72.5", "", "2", "0", "", "104", "1", "2", "48", "1", "0", "", "", "", "0", "", "", "", "", "1", "7.425", "0.106", "0.002", "1.32645", "", "", "", "", "", "", "", "", "8325", "", "", "", "", "", "", "", "", "91.5", "100.2", "", "", "", "", "98.5"]} -{"pcdb_id": 18792, "brand_name": "Worcester", "model_name": "Greenstar 8000 Life", "model_qualifier": "GR8300iW 45 R LPG", "winter_efficiency_pct": 90.2, "summer_efficiency_pct": 81.2, "comparative_hot_water_efficiency_pct": 59.3, "output_kw_max": 42.0, "final_year_of_manufacture": null, "raw": ["018792", "000035", "0", "2020/Apr/15 11:27", "Bosch Thermotechnology", "Worcester", "Greenstar 8000 Life", "GR8300iW 45 R LPG", "41-800-01", "2018", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "42", "42", "", "", "90.2", "81.2", "", "59.3", "", "2", "0", "", "102", "1", "2", "84", "1", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0305", "", "", "", "", "", "", "", "", "90.9", "98.9", "", "", "", "", "97.4"]} -{"pcdb_id": 18793, "brand_name": "Worcester", "model_name": "Greenstar 8000 Life", "model_qualifier": "GR8300iW 50 C LPG", "winter_efficiency_pct": 90.6, "summer_efficiency_pct": 89.1, "comparative_hot_water_efficiency_pct": 74.5, "output_kw_max": 33.7, "final_year_of_manufacture": null, "raw": ["018793", "000035", "0", "2020/Jul/16 19:00", "Bosch Thermotechnology", "Worcester", "Greenstar 8000 Life", "GR8300iW 50 C LPG", "47-800-19", "2018", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "33.7", "33.7", "", "", "90.6", "89.1", "", "74.5", "", "2", "0", "", "104", "1", "2", "48", "1", "0", "", "", "", "0", "", "", "", "", "1", "7.228", "0.115", "0.0025", "1.13294", "", "", "", "", "", "", "", "", "8325", "", "", "", "", "", "", "", "", "91.5", "99.9", "", "", "", "", "98.3"]} -{"pcdb_id": 18794, "brand_name": "Worcester", "model_name": "Greenstar 8000 Life", "model_qualifier": "GR8300iW 50 R LPG", "winter_efficiency_pct": 90.3, "summer_efficiency_pct": 81.3, "comparative_hot_water_efficiency_pct": 59.4, "output_kw_max": 47.9, "final_year_of_manufacture": null, "raw": ["018794", "000035", "0", "2020/Apr/15 11:28", "Bosch Thermotechnology", "Worcester", "Greenstar 8000 Life", "GR8300iW 50 R LPG", "41-406-99", "2018", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "47.9", "47.9", "", "", "90.3", "81.3", "", "59.4", "", "2", "0", "", "102", "1", "2", "84", "1", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0305", "", "", "", "", "", "", "", "", "90.8", "99.2", "", "", "", "", "97.6"]} -{"pcdb_id": 18795, "brand_name": "Alpha", "model_name": "E-Tec", "model_qualifier": "35S", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 32.0, "final_year_of_manufacture": null, "raw": ["018795", "000001", "0", "2020/Jun/10 14:17", "Alpha Therm", "Alpha", "E-Tec", "35S", "3.028471", "2020", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "32", "32", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "42", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "1005", "", "", "", "", "", "", "", "", "88.1", "97.8", "", "", "", "", "95.9"]} -{"pcdb_id": 18796, "brand_name": "Alpha", "model_name": "E-Tec", "model_qualifier": "Plus 38", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 83.1, "comparative_hot_water_efficiency_pct": 75.7, "output_kw_max": 32.0, "final_year_of_manufacture": null, "raw": ["018796", "000001", "0", "2020/Jun/10 14:16", "Alpha Therm", "Alpha", "E-Tec", "Plus 38", "3.028468", "2020", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "32", "32", "", "", "88.4", "83.1", "", "75.7", "", "2", "", "", "104", "1", "2", "42", "2", "0", "", "", "0.02", "0", "", "", "", "", "2", "6.956", "0.063", "0.0004", "0.84825", "13.316", "0.081", "0.0049", "0.43872", "-0.00005", "", "", "", "1005", "", "", "", "", "", "", "", "", "88.1", "97.8", "", "", "", "", "95.9"]} -{"pcdb_id": 18816, "brand_name": "Baxi", "model_name": "816 HEAT", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 16.0, "final_year_of_manufacture": null, "raw": ["018816", "000005", "0", "2020/Jun/15 11:55", "Baxi Heating UK", "Baxi", "816 HEAT", "", "41-470-77", "2020", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "16", "16", "", "", "88.6", "79.6", "", "58.2", "", "2", "", "", "102", "1", "2", "20", " 0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "98.4", "", "", "", "", "96.4"]} -{"pcdb_id": 18817, "brand_name": "Baxi", "model_name": "825 HEAT", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 25.0, "final_year_of_manufacture": null, "raw": ["018817", "000005", "0", "2020/Jun/15 11:56", "Baxi Heating UK", "Baxi", "825 HEAT", "", "41-470-78", "2020", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "25", "25", "", "", "88.6", "79.6", "", "58.2", "", "2", "", "", "102", "1", "2", "33", " 0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "98.4", "", "", "", "", "96.4"]} -{"pcdb_id": 18818, "brand_name": "Baxi", "model_name": "830 HEAT", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 30.0, "final_year_of_manufacture": null, "raw": ["018818", "000005", "0", "2020/Jun/15 11:56", "Baxi Heating UK", "Baxi", "830 HEAT", "", "41-470-79", "2020", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "30", "30", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "44", " 0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.3", "98.0", "", "", "", "", "96.0"]} -{"pcdb_id": 18819, "brand_name": "Baxi", "model_name": "Platinum+", "model_qualifier": "32 System", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 32.0, "final_year_of_manufacture": null, "raw": ["018819", "000005", "0", "2020/Jun/30 13:42", "Baxi Heating UK", "Baxi", "Platinum+", "32 System", "GC No. 41-470-95", "2020", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "32", "32", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "43", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "87.7", "96.9", "", "", "", "", "95.1"]} -{"pcdb_id": 18820, "brand_name": "Worcester", "model_name": "Greenstar 2000", "model_qualifier": "GR2300iW 25 C NG", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 88.2, "comparative_hot_water_efficiency_pct": 75.5, "output_kw_max": 20.0, "final_year_of_manufacture": null, "raw": ["018820", "000035", "0", "2020/Aug/12 09:40", "Bosch Thermotechnology", "Worcester", "Greenstar 2000", "GR2300iW 25 C NG", "47-800-26", "2020", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "20", "20", "", "", "88.4", "88.2", "", "75.5", "", "2", "", "", "104", "1", "2", "28", "3", "0", "", "", "", "0", "", "", "", "", "2", "6.973", "0.077", "0.0025", "0.84293", "12.745", "0.098", "0.0015", "0.82982", "0.00001", "", "", "", "8305", "", "", "", "", "", "", "", "", "87.8", "98.0", "", "", "", "", "96.1"]} -{"pcdb_id": 18821, "brand_name": "Worcester", "model_name": "Greenstar 2000", "model_qualifier": "GR2300iW 30 C NG", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 88.0, "comparative_hot_water_efficiency_pct": 76.3, "output_kw_max": 20.0, "final_year_of_manufacture": null, "raw": ["018821", "000035", "0", "2020/Aug/12 09:54", "Bosch Thermotechnology", "Worcester", "Greenstar 2000", "GR2300iW 30 C NG", "47-800-28", "2020", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "20", "20", "", "", "88.4", "88.0", "", "76.3", "", "2", "", "", "104", "1", "2", "28", "3", "0", "", "", "", "0", "", "", "", "", "2", "6.901", "0.069", "0.005", "0.75911", "12.842", "0.101", "0.0021", "0.73376", "0.00003", "", "", "", "8305", "", "", "", "", "", "", "", "", "87.8", "98.0", "", "", "", "", "96.1"]} -{"pcdb_id": 18822, "brand_name": "Glow-worm", "model_name": "Energy7", "model_qualifier": "12r - A (H-GB)", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 12.3, "final_year_of_manufacture": null, "raw": ["018822", "000207", "0", "2020/Aug/19 12:58", "Vaillant Group UK", "Glow-worm", "Energy7", "12r - A (H-GB)", "47-019-58", "2020", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "12.3", "12.3", "", "", "89.1", "80.1", "", "58.5", "", "2", "", "", "102", "1", "2", "19", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0085", "", "", "", "", "", "", "", "", "89.3", "99.0", "", "", "", "", "97.2"]} -{"pcdb_id": 18823, "brand_name": "Glow-worm", "model_name": "Energy7", "model_qualifier": "12s - A (H-GB)", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 12.3, "final_year_of_manufacture": null, "raw": ["018823", "000207", "0", "2020/Aug/19 12:58", "Vaillant Group UK", "Glow-worm", "Energy7", "12s - A (H-GB)", "47-019-53", "2020", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "12.3", "12.3", "", "", "89.1", "80.1", "", "58.5", "", "2", "", "", "102", "1", "2", "19", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0085", "", "", "", "", "", "", "", "", "89.3", "99.0", "", "", "", "", "97.2"]} -{"pcdb_id": 18824, "brand_name": "Glow-worm", "model_name": "Energy7", "model_qualifier": "15r - A (H-GB)", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 15.3, "final_year_of_manufacture": null, "raw": ["018824", "000207", "0", "2020/Aug/19 12:58", "Vaillant Group UK", "Glow-worm", "Energy7", "15r - A (H-GB)", "47-019-59", "2020", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "15.3", "15.3", "", "", "89.1", "80.1", "", "58.5", "", "2", "", "", "102", "1", "2", "19", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0085", "", "", "", "", "", "", "", "", "89.1", "99.1", "", "", "", "", "97.2"]} -{"pcdb_id": 18825, "brand_name": "Glow-worm", "model_name": "Energy7", "model_qualifier": "15s - A (H-GB)", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 15.3, "final_year_of_manufacture": null, "raw": ["018825", "000207", "0", "2020/Aug/19 12:58", "Vaillant Group UK", "Glow-worm", "Energy7", "15s - A (H-GB)", "47-019-54", "2020", "current", "1", "2", "1", "1", "0", "", "", "2", "1", "2", "15.3", "15.3", "", "", "89.1", "80.1", "", "58.5", "", "2", "", "", "102", "1", "2", "37", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0085", "", "", "", "", "", "", "", "", "89.1", "99.1", "", "", "", "", "97.2"]} -{"pcdb_id": 18826, "brand_name": "Glow-worm", "model_name": "Energy7", "model_qualifier": "18r - A (H-GB)", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 18.4, "final_year_of_manufacture": null, "raw": ["018826", "000207", "0", "2020/Aug/19 12:58", "Vaillant Group UK", "Glow-worm", "Energy7", "18r - A (H-GB)", "47-019-60", "2020", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18.4", "18.4", "", "", "89.0", "80.0", "", "58.4", "", "2", "", "", "102", "1", "2", "21", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0085", "", "", "", "", "", "", "", "", "89.0", "98.9", "", "", "", "", "97.0"]} -{"pcdb_id": 18827, "brand_name": "Glow-worm", "model_name": "Energy7", "model_qualifier": "18s - A (H-GB)", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 18.4, "final_year_of_manufacture": null, "raw": ["018827", "000207", "0", "2020/Aug/19 12:58", "Vaillant Group UK", "Glow-worm", "Energy7", "18s - A (H-GB)", "47-019-55", "2020", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18.4", "18.4", "", "", "89.0", "80.0", "", "58.4", "", "2", "", "", "102", "1", "2", "21", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0085", "", "", "", "", "", "", "", "", "89.0", "98.9", "", "", "", "", "97.0"]} -{"pcdb_id": 18828, "brand_name": "Glow-worm", "model_name": "Energy7", "model_qualifier": "25r - A (H-GB)", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 24.7, "final_year_of_manufacture": null, "raw": ["018828", "000207", "0", "2020/Aug/19 12:58", "Vaillant Group UK", "Glow-worm", "Energy7", "25r - A (H-GB)", "47-019-61", "2020", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24.7", "24.7", "", "", "89.1", "80.1", "", "58.5", "", "2", "", "", "102", "1", "2", "29", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0085", "", "", "", "", "", "", "", "", "89.2", "99.1", "", "", "", "", "97.2"]} -{"pcdb_id": 18829, "brand_name": "Glow-worm", "model_name": "Energy7", "model_qualifier": "25s - A (H-GB)", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 24.7, "final_year_of_manufacture": null, "raw": ["018829", "000207", "0", "2020/Aug/19 12:58", "Vaillant Group UK", "Glow-worm", "Energy7", "25s - A (H-GB)", "47-019-56", "2020", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24.7", "24.7", "", "", "89.1", "80.1", "", "58.5", "", "2", "", "", "102", "1", "2", "29", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0085", "", "", "", "", "", "", "", "", "89.2", "99.1", "", "", "", "", "97.2"]} -{"pcdb_id": 18830, "brand_name": "Glow-worm", "model_name": "Energy7", "model_qualifier": "25c - A (H-GB)", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 78.9, "comparative_hot_water_efficiency_pct": 70.4, "output_kw_max": 18.4, "final_year_of_manufacture": null, "raw": ["018830", "000207", "0", "2020/Aug/20 16:44", "Vaillant Group UK", "Glow-worm", "Energy7", "25c - A (H-GB)", "47-019-60", "2020", "current", "1", "2", "1", "2", "0", "", "", "2", "1", "2", "18.4", "18.4", "", "", "89.0", "78.9", "", "70.4", "", "2", "", "", "104", "1", "2", "21", "2", "0", "", "", "0", "0", "", "", "", "", "2", "7.484", "0.067", "0.0028", "1.36644", "14.1", "0.105", "0.0", "0.56093", "0.00003", "", "", "", "0085", "", "", "", "", "", "", "", "", "89.0", "98.9", "", "", "", "", "97.0"]} -{"pcdb_id": 18831, "brand_name": "Glow-worm", "model_name": "Energy7", "model_qualifier": "30r - A (H-GB)", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 35.0, "final_year_of_manufacture": null, "raw": ["018831", "000207", "0", "2020/Aug/19 12:58", "Vaillant Group UK", "Glow-worm", "Energy7", "30r - A (H-GB)", "47-019-62", "2020", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "35", "35", "", "", "89.1", "80.1", "", "58.5", "", "2", "", "", "102", "1", "2", "29", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0085", "", "", "", "", "", "", "", "", "89.5", "98.9", "", "", "", "", "97.1"]} -{"pcdb_id": 18832, "brand_name": "Glow-worm", "model_name": "Energy7", "model_qualifier": "30s - A (H-GB)", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 35.0, "final_year_of_manufacture": null, "raw": ["018832", "000207", "0", "2020/Aug/19 12:58", "Vaillant Group UK", "Glow-worm", "Energy7", "30s - A (H-GB)", "47-019-57", "2020", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "35", "35", "", "", "89.1", "80.1", "", "58.5", "", "2", "", "", "102", "1", "2", "37", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0085", "", "", "", "", "", "", "", "", "89.5", "98.9", "", "", "", "", "97.1"]} -{"pcdb_id": 18833, "brand_name": "Glow-worm", "model_name": "Energy7", "model_qualifier": "30c - A (H-GB)", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 83.9, "comparative_hot_water_efficiency_pct": 68.7, "output_kw_max": 24.7, "final_year_of_manufacture": null, "raw": ["018833", "000207", "0", "2020/Aug/20 16:44", "Vaillant Group UK", "Glow-worm", "Energy7", "30c - A (H-GB)", "47-019-61", "2020", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.7", "24.7", "", "", "89.1", "83.9", "", "68.7", "", "2", "", "", "104", "1", "2", "21", "2", "0", "", "", "", "0", "", "", "", "", "2", "7.661", "0.067", "0.0029", "1.54181", "13.885", "0.094", "0.0", "1.1256", "0.00003", "", "", "", "0085", "", "", "", "", "", "", "", "", "89.2", "99.1", "", "", "", "", "97.2"]} -{"pcdb_id": 18834, "brand_name": "Glow-worm", "model_name": "Energy7", "model_qualifier": "35c - A (H-GB)", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 74.2, "comparative_hot_water_efficiency_pct": 76.1, "output_kw_max": 35.0, "final_year_of_manufacture": null, "raw": ["018834", "000207", "0", "2020/Aug/20 16:44", "Vaillant Group UK", "Glow-worm", "Energy7", "35c - A (H-GB)", "47-019-62", "2020", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "35", "35", "", "", "89.1", "74.2", "", "76.1", "", "2", "", "", "104", "1", "2", "29", "2", "0", "", "", "", "0", "", "", "", "", "2", "6.921", "0.096", "0.0045", "0.82431", "13.945", "0.114", "0.0", "0.0", "0.00005", "", "", "", "0085", "", "", "", "", "", "", "", "", "89.5", "98.9", "", "", "", "", "97.1"]} -{"pcdb_id": 18842, "brand_name": "E.C.A.", "model_name": "Confeo Premix P", "model_qualifier": "24 HCH NG ERP YBK UK", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 24.5, "final_year_of_manufacture": null, "raw": ["018842", "000248", "0", "2020/Oct/20 10:02", "Emas Makina Sanayi", "E.C.A.", "Confeo Premix P", "24 HCH NG ERP YBK UK", "GC No 41-814-31", "2020", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24.5", "24.5", "", "", "88.1", "79.1", "", "57.8", "", "2", "", "", "102", "1", "2", "40", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "97.1", "", "", "", "", "95.3"]} -{"pcdb_id": 18843, "brand_name": "E.C.A.", "model_name": "Confeo Premix P", "model_qualifier": "24 HM NG ERP YBK UK", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 55.9, "output_kw_max": 24.5, "final_year_of_manufacture": null, "raw": ["018843", "000248", "0", "2020/Oct/20 10:02", "Emas Makina Sanayi", "E.C.A.", "Confeo Premix P", "24 HM NG ERP YBK UK", "GC No 47-814-17", "2020", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.5", "24.5", "", "", "88.1", "79.5", "", "55.9", "", "2", "", "", "104", "1", "2", "40", "5", "0", "", "", "4.22", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "97.1", "", "", "", "", "95.3"]} -{"pcdb_id": 18844, "brand_name": "E.C.A.", "model_name": "Confeo Premix P", "model_qualifier": "24 HST NG ERP YBK UK", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 24.5, "final_year_of_manufacture": null, "raw": ["018844", "000248", "0", "2020/Oct/20 10:02", "Emas Makina Sanayi", "E.C.A.", "Confeo Premix P", "24 HST NG ERP YBK UK", "GC No 41-814-37", "2020", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24.5", "24.5", "", "", "88.1", "79.1", "", "57.8", "", "2", "", "", "102", "1", "2", "40", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "97.1", "", "", "", "", "95.3"]} -{"pcdb_id": 18845, "brand_name": "E.C.A.", "model_name": "Confeo Premix P", "model_qualifier": "28 HCH NG ERP YBK UK", "winter_efficiency_pct": 87.8, "summer_efficiency_pct": 78.8, "comparative_hot_water_efficiency_pct": 57.6, "output_kw_max": 28.0, "final_year_of_manufacture": null, "raw": ["018845", "000248", "0", "2020/Oct/20 10:02", "Emas Makina Sanayi", "E.C.A.", "Confeo Premix P", "28 HCH NG ERP YBK UK", "GC No 41-814-32", "2020", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "28", "28", "", "", "87.8", "78.8", "", "57.6", "", "2", "", "", "102", "1", "2", "51", "4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.2", "96.7", "", "", "", "", "94.9"]} -{"pcdb_id": 18846, "brand_name": "E.C.A.", "model_name": "Confeo Premix P", "model_qualifier": "28 HM NG ERP YBK UK", "winter_efficiency_pct": 87.8, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 55.7, "output_kw_max": 28.0, "final_year_of_manufacture": null, "raw": ["018846", "000248", "0", "2020/Oct/20 10:02", "Emas Makina Sanayi", "E.C.A.", "Confeo Premix P", "28 HM NG ERP YBK UK", "GC No 47-814-18", "2020", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28", "28", "", "", "87.8", "79.2", "", "55.7", "", "2", "", "", "104", "1", "2", "51", "4", "0", "", "", "5.02", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.2", "96.7", "", "", "", "", "94.9"]} -{"pcdb_id": 18847, "brand_name": "E.C.A.", "model_name": "Confeo Premix P", "model_qualifier": "28 HST NG ERP YBK UK", "winter_efficiency_pct": 87.8, "summer_efficiency_pct": 78.8, "comparative_hot_water_efficiency_pct": 57.6, "output_kw_max": 28.0, "final_year_of_manufacture": null, "raw": ["018847", "000248", "0", "2020/Oct/20 10:03", "Emas Makina Sanayi", "E.C.A.", "Confeo Premix P", "28 HST NG ERP YBK UK", "GC No 41-814-38", "2020", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "28", "28", "", "", "87.8", "78.8", "", "57.6", "", "2", "", "", "102", "1", "2", "51", "4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.2", "96.7", "", "", "", "", "94.9"]} -{"pcdb_id": 18848, "brand_name": "E.C.A.", "model_name": "Confeo Premix P", "model_qualifier": "30 HCH NG ERP YBK UK", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 30.0, "final_year_of_manufacture": null, "raw": ["018848", "000248", "0", "2020/Oct/20 10:03", "Emas Makina Sanayi", "E.C.A.", "Confeo Premix P", "30 HCH NG ERP YBK UK", "GC No 41-814-33", "2020", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "30", "30", "", "", "88.1", "79.1", "", "57.8", "", "2", "", "", "102", "1", "2", "56", "4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.5", "97.3", "", "", "", "", "95.4"]} -{"pcdb_id": 18849, "brand_name": "E.C.A.", "model_name": "Confeo Premix P", "model_qualifier": "30 HM NG ERP YBK UK", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 55.9, "output_kw_max": 30.0, "final_year_of_manufacture": null, "raw": ["018849", "000248", "0", "2020/Oct/20 10:03", "Emas Makina Sanayi", "E.C.A.", "Confeo Premix P", "30 HM NG ERP YBK UK", "GC No 47-814-19", "2020", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "30", "30", "", "", "88.1", "79.5", "", "55.9", "", "2", "", "", "104", "1", "2", "56", "4", "0", "", "", "5.02", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.5", "97.3", "", "", "", "", "95.4"]} -{"pcdb_id": 18850, "brand_name": "E.C.A.", "model_name": "Confeo Premix P", "model_qualifier": "30 HST NG ERP YBK UK", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 30.0, "final_year_of_manufacture": null, "raw": ["018850", "000248", "0", "2020/Oct/20 10:03", "Emas Makina Sanayi", "E.C.A.", "Confeo Premix P", "30 HST NG ERP YBK UK", "GC No 41-814-39", "2020", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "30", "30", "", "", "88.1", "79.1", "", "57.8", "", "2", "", "", "102", "1", "2", "56", "4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.5", "97.3", "", "", "", "", "95.4"]} -{"pcdb_id": 18851, "brand_name": "E.C.A.", "model_name": "Confeo Premix P", "model_qualifier": "35 HCH NG ERP YBK UK", "winter_efficiency_pct": 87.7, "summer_efficiency_pct": 78.7, "comparative_hot_water_efficiency_pct": 57.5, "output_kw_max": 35.0, "final_year_of_manufacture": null, "raw": ["018851", "000248", "0", "2020/Oct/20 10:04", "Emas Makina Sanayi", "E.C.A.", "Confeo Premix P", "35 HCH NG ERP YBK UK", "GC No 41-814-34", "2020", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "35", "35", "", "", "87.7", "78.7", "", "57.5", "", "2", "", "", "102", "1", "2", "66", "4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.4", "96.4", "", "", "", "", "94.7"]} -{"pcdb_id": 18852, "brand_name": "E.C.A.", "model_name": "Confeo Premix P", "model_qualifier": "35 HM NG ERP YBK UK", "winter_efficiency_pct": 87.7, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 55.7, "output_kw_max": 35.0, "final_year_of_manufacture": null, "raw": ["018852", "000248", "0", "2020/Oct/20 10:04", "Emas Makina Sanayi", "E.C.A.", "Confeo Premix P", "35 HM NG ERP YBK UK", "GC No 47-814-20", "2020", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "35", "35", "", "", "87.7", "79.1", "", "55.7", "", "2", "", "", "104", "1", "2", "66", "4", "0", "", "", "5.6", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.4", "96.4", "", "", "", "", "94.7"]} -{"pcdb_id": 18853, "brand_name": "E.C.A.", "model_name": "Confeo Premix P", "model_qualifier": "35 HST NG ERP YBK UK", "winter_efficiency_pct": 87.7, "summer_efficiency_pct": 78.7, "comparative_hot_water_efficiency_pct": 57.5, "output_kw_max": 35.0, "final_year_of_manufacture": null, "raw": ["018853", "000248", "0", "2020/Oct/20 10:04", "Emas Makina Sanayi", "E.C.A.", "Confeo Premix P", "35 HST NG ERP YBK UK", "GC No 41-814-40", "2020", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "35", "35", "", "", "87.7", "78.7", "", "57.5", "", "2", "", "", "102", "1", "2", "66", "4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.4", "96.4", "", "", "", "", "94.7"]} -{"pcdb_id": 18854, "brand_name": "Vokera BY RIELLO", "model_name": "Vision PLUS", "model_qualifier": "30C", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 56.1, "output_kw_max": 24.45, "final_year_of_manufacture": null, "raw": ["018854", "000011", "0", "2020/Nov/02 11:27", "Vokera", "Vokera BY RIELLO", "Vision PLUS", "30C", "20173521", "2020", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.45", "24.45", "", "", "88.4", "79.8", "", "56.1", "", "2", "", "", "104", "1", "2", "38", "3", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.1", "97.8", "", "", "", "", "96.0"]} -{"pcdb_id": 18855, "brand_name": "Vokera BY RIELLO", "model_name": "Vision PLUS", "model_qualifier": "25C", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 56.1, "output_kw_max": 19.5, "final_year_of_manufacture": null, "raw": ["018855", "000011", "0", "2020/Nov/02 11:29", "Vokera", "Vokera BY RIELLO", "Vision PLUS", "25C", "20173520", "2020", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "19.5", "19.5", "", "", "88.4", "79.8", "", "56.1", "", "2", "", "", "104", "1", "2", "29", "3", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "97.8", "", "", "", "", "95.9"]} -{"pcdb_id": 18856, "brand_name": "Vokera BY RIELLO", "model_name": "Vision PLUS", "model_qualifier": "20S", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 19.46, "final_year_of_manufacture": null, "raw": ["018856", "000011", "0", "2021/Jan/15 11:27", "Vokera", "Vokera BY RIELLO", "Vision PLUS", "20S", "20174726", "2020", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "19.46", "19.46", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "28", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "87.7", "96.9", "", "", "", "", "95.2"]} -{"pcdb_id": 18857, "brand_name": "Vokera BY RIELLO", "model_name": "Vision PLUS", "model_qualifier": "25S", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 24.38, "final_year_of_manufacture": null, "raw": ["018857", "000011", "0", "2021/Jan/15 11:28", "Vokera", "Vokera BY RIELLO", "Vision PLUS", "25S", "20174728", "2020", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24.38", "24.38", "", "", "88.1", "79.1", "", "57.8", "", "2", "", "", "102", "1", "2", "30", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "87.8", "97.1", "", "", "", "", "95.4"]} -{"pcdb_id": 18858, "brand_name": "Vokera BY RIELLO", "model_name": "Vision PLUS", "model_qualifier": "30S", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 29.25, "final_year_of_manufacture": null, "raw": ["018858", "000011", "0", "2021/Jan/15 11:28", "Vokera", "Vokera BY RIELLO", "Vision PLUS", "30S", "20174729", "2020", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "29.25", "29.25", "", "", "88.1", "79.1", "", "57.8", "", "2", "", "", "102", "1", "2", "41", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "87.8", "97.1", "", "", "", "", "95.4"]} -{"pcdb_id": 18859, "brand_name": "Vokera BY RIELLO", "model_name": "Vision PLUS", "model_qualifier": "35C", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 55.9, "output_kw_max": 29.25, "final_year_of_manufacture": null, "raw": ["018859", "000011", "0", "2021/Jan/15 11:28", "Vokera", "Vokera BY RIELLO", "Vision PLUS", "35C", "20174724", "2020", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "29.25", "29.25", "", "", "88.1", "79.5", "", "55.9", "", "2", "", "", "104", "1", "2", "41", "3", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "87.8", "97.1", "", "", "", "", "95.4"]} -{"pcdb_id": 18860, "brand_name": "Vokera BY RIELLO", "model_name": "Vision PLUS", "model_qualifier": "40C", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 55.8, "output_kw_max": 29.25, "final_year_of_manufacture": null, "raw": ["018860", "000011", "0", "2021/Jan/15 11:29", "Vokera", "Vokera BY RIELLO", "Vision PLUS", "40C", "20174725", "2020", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "29.25", "29.25", "", "", "87.9", "79.3", "", "55.8", "", "2", "", "", "104", "1", "2", "41", "3", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "87.8", "96.6", "", "", "", "", "94.9"]} -{"pcdb_id": 18863, "brand_name": "ATAG", "model_name": "A325EC", "model_qualifier": "X", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 85.2, "output_kw_max": 28.8, "final_year_of_manufacture": null, "raw": ["018863", "000227", "0", "2021/Nov/29 13:53", "ATAG Verwarming Nederland BV", "ATAG", "A325EC", "X", "", "2010", "current", "1", "2", "1", "2", "1", "", "", "2", "3", "2", "28.8", "28.8", "", "", "89.1", "87.3", "", "85.2", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "", "0", "", "", "", "", "1", "6.18", "0.178", "0.0008", "0.13684", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.8", "98.8", "", "", "", "", "97.1"]} -{"pcdb_id": 18864, "brand_name": "Ideal", "model_name": "Logic Code Combi", "model_qualifier": "26", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 75.1, "output_kw_max": 24.2, "final_year_of_manufacture": 2013, "raw": ["018864", "000008", "0", "2021/Nov/29 13:53", "Ideal Boilers", "Ideal", "Logic Code Combi", "26", "47-348-74", "2011", "2013", "1", "2", "1", "2", "1", "", "", "2", "2", "2", "24.2", "24.2", "", "", "88.4", "87.3", "", "75.1", "", "2", "", "", "104", "1", "2", "146", "1", "0", "", "", "0", "0", "", "", "", "", "1", "7.0133", "0.1547", "0.0048", "0.92126", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.8", "96.9", "", "", "", "", "95.6"]} -{"pcdb_id": 18865, "brand_name": "Ideal", "model_name": "Logic Code Combi", "model_qualifier": "33", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 75.8, "output_kw_max": 24.2, "final_year_of_manufacture": 2013, "raw": ["018865", "000008", "0", "2021/Nov/29 13:53", "Ideal Boilers", "Ideal", "Logic Code Combi", "33", "47-348-75", "2011", "2013", "1", "2", "1", "2", "1", "", "", "2", "2", "2", "24.2", "24.2", "", "", "88.4", "87.3", "", "75.8", "", "2", "", "", "104", "1", "2", "152", "1", "0", "", "", "0", "0", "", "", "", "", "1", "6.9512", "0.1528", "0.0045", "0.86711", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.0", "96.9", "", "", "", "", "95.6"]} -{"pcdb_id": 18866, "brand_name": "Ideal", "model_name": "Logic Code Combi", "model_qualifier": "38", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 75.8, "output_kw_max": 24.2, "final_year_of_manufacture": 2013, "raw": ["018866", "000008", "0", "2021/Nov/29 13:53", "Ideal Boilers", "Ideal", "Logic Code Combi", "38", "47-348-76", "2011", "2013", "1", "2", "1", "2", "1", "", "", "2", "2", "2", "24.2", "24.2", "", "", "88.3", "87.3", "", "75.8", "", "2", "", "", "104", "1", "2", "177", "1", "0", "", "", "0", "0", "", "", "", "", "1", "6.9449", "0.1539", "0.0082", "0.83483", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.8", "96.9", "", "", "", "", "95.5"]} -{"pcdb_id": 18867, "brand_name": "Alpha", "model_name": "InTec 30GS", "model_qualifier": "", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 80.6, "comparative_hot_water_efficiency_pct": 56.7, "output_kw_max": 18.3, "final_year_of_manufacture": null, "raw": ["018867", "000001", "0", "2021/Nov/29 13:53", "Alpha Therm", "Alpha", "InTec 30GS", "", "", "2011", "current", "2", "2", "1", "2", "1", "313", "060085", "2", "2", "2", "18.3", "18.3", "", "", "89.2", "80.6", "", "56.7", "", "2", "1", "", "104", "1", "2", "120", "6", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "1005", "", "", "", "", "", "", "", "", "90.7", "99.1", "", "", "", "", "97.5"]} -{"pcdb_id": 18868, "brand_name": "Alpha", "model_name": "InTec 30GS", "model_qualifier": "", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 86.9, "comparative_hot_water_efficiency_pct": 81.0, "output_kw_max": 18.3, "final_year_of_manufacture": null, "raw": ["018868", "000001", "0", "2021/Nov/29 13:53", "Alpha Therm", "Alpha", "InTec 30GS", "", "", "2011", "current", "1", "2", "1", "2", "1", "313", "060084", "2", "2", "2", "18.3", "18.3", "", "", "88.2", "86.9", "", "81.0", "", "2", "", "", "104", "1", "2", "120", "6", "0", "", "", "", "0", "", "", "", "", "1", "6.5", "0.147", "0.0085", "0.37658", "", "", "", "", "", "", "", "", "1005", "", "", "", "", "", "", "", "", "88.7", "96.9", "", "", "", "", "95.4"]} -{"pcdb_id": 18869, "brand_name": "Alpha", "model_name": "InTec 40GS", "model_qualifier": "", "winter_efficiency_pct": 89.3, "summer_efficiency_pct": 80.7, "comparative_hot_water_efficiency_pct": 56.8, "output_kw_max": 28.0, "final_year_of_manufacture": null, "raw": ["018869", "000001", "0", "2021/Nov/29 13:53", "Alpha Therm", "Alpha", "InTec 40GS", "", "", "2011", "current", "2", "2", "1", "2", "1", "313", "060085", "2", "2", "2", "28", "28", "", "", "89.3", "80.7", "", "56.8", "", "2", "1", "", "104", "1", "2", "125", "6", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "1005", "", "", "", "", "", "", "", "", "91.4", "99.2", "", "", "", "", "97.7"]} -{"pcdb_id": 18870, "brand_name": "Alpha", "model_name": "InTec 40GS", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 87.1, "comparative_hot_water_efficiency_pct": 79.4, "output_kw_max": 28.0, "final_year_of_manufacture": null, "raw": ["018870", "000001", "0", "2021/Nov/29 13:53", "Alpha Therm", "Alpha", "InTec 40GS", "", "", "2011", "current", "1", "2", "1", "2", "1", "313", "060084", "2", "2", "2", "28", "28", "", "", "88.3", "87.1", "", "79.4", "", "2", "", "", "104", "1", "2", "125", "6", "0", "", "", "", "0", "", "", "", "", "1", "6.631", "0.121", "0.007", "0.52692", "", "", "", "", "", "", "", "", "1005", "", "", "", "", "", "", "", "", "89.4", "97.0", "", "", "", "", "95.6"]} -{"pcdb_id": 18871, "brand_name": "Alpha", "model_name": "InTec 40 GS2", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 98.9, "comparative_hot_water_efficiency_pct": 81.0, "output_kw_max": 28.0, "final_year_of_manufacture": null, "raw": ["018871", "000001", "0", "2021/Nov/29 13:53", "Alpha Therm", "Alpha", "InTec 40 GS2", "", "3.028276", "2017", "current", "1", "2", "1", "2", "1", "313", "060086", "2", "2", "2", "28.0", "28.0", "", "", "88.3", "98.9", "", "81.0", "", "2", "", "", "104", "1", "2", "37", "6", "0", "", "", "", "0", "", "", "", "", "2", "6.5", "0.208", "0.0035", "0.42069", "11.79", "0.23", "0.0015", "1.1267", "0.00002", "", "", "", "1005", "", "", "", "", "", "", "", "", "89.4", "97.0", "", "", "", "", "95.6"]} -{"pcdb_id": 18872, "brand_name": "ATAG", "model_name": "IC Economiser Plus 35", "model_qualifier": "", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 97.8, "comparative_hot_water_efficiency_pct": 79.9, "output_kw_max": 28.3, "final_year_of_manufacture": null, "raw": ["018872", "000299", "0", "2021/Nov/29 13:53", "ATAG Verwarming Nederland BV", "ATAG", "IC Economiser Plus 35", "", "", "2018", "current", "1", "2", "1", "2", "1", "", "", "2", "3", "2", "28.3", "28.3", "", "", "89.1", "97.8", "", "79.9", "", "2", "", "", "104", "1", "2", "74", "4", "0", "", "", "", "0", "", "", "", "", "2", "6.59", "0.168", "0.0013", "0.50098", "11.94", "0.183", "0.0007", "1.1609", "0.00001", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.6", "99.5", "", "", "", "", "97.4"]} -{"pcdb_id": 18873, "brand_name": "ATAG", "model_name": "IC Economiser Plus 39", "model_qualifier": "", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 97.8, "comparative_hot_water_efficiency_pct": 79.9, "output_kw_max": 28.3, "final_year_of_manufacture": null, "raw": ["018873", "000299", "0", "2021/Nov/29 13:53", "ATAG Verwarming Nederland BV", "ATAG", "IC Economiser Plus 39", "", "", "2018", "current", "1", "2", "1", "2", "1", "", "", "2", "3", "2", "28.3", "28.3", "", "", "89.1", "97.8", "", "79.9", "", "2", "", "", "104", "1", "2", "74", "4", "0", "", "", "", "0", "", "", "", "", "2", "6.59", "0.168", "0.0013", "0.50098", "11.94", "0.183", "0.0007", "1.1609", "0.00001", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.6", "99.5", "", "", "", "", "97.4"]} -{"pcdb_id": 18900, "brand_name": "Warmhaus", "model_name": "Ewa", "model_qualifier": "2530 C 30 KW", "winter_efficiency_pct": 84.4, "summer_efficiency_pct": 75.8, "comparative_hot_water_efficiency_pct": 59.1, "output_kw_max": 23.7, "final_year_of_manufacture": null, "raw": ["018900", "020152", "0", "2021/Mar/25 10:06", "Warmhaus Isitma ve Sogutma Sistemleri Sanayi", "Warmhaus", "Ewa", "2530 C 30 KW", "8699104832925", "2019", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "23.7", "23.7", "A", "", "84.4", "75.8", "", "59.1", "", "2", "", "", "104", "2", "2", "43", "5", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "", "", "0005", "", "A", "84", "XL", "92", "11", "79", "57.0", "88.3", "97.6", "", "", "", "", "95.8"]} -{"pcdb_id": 18901, "brand_name": "Warmhaus", "model_name": "Minerwa", "model_qualifier": "2500 HO 25 KW", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 23.7, "final_year_of_manufacture": null, "raw": ["018901", "020152", "0", "2021/Mar/25 10:07", "Warmhaus Isitma ve Sogutma Sistemleri Sanayi", "Warmhaus", "Minerwa", "2500 HO 25 KW", "8699104832949", "2020", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "23.7", "23.7", "A", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "43", "5", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "92", "11", "79", "27.0", "88.3", "97.6", "", "", "", "", "95.8"]} -{"pcdb_id": 18902, "brand_name": "Warmhaus", "model_name": "Ewa", "model_qualifier": "2525 C 25 KW", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 62.3, "output_kw_max": 23.7, "final_year_of_manufacture": null, "raw": ["018902", "020152", "0", "2021/Mar/25 10:08", "Warmhaus Isitma ve Sogutma Sistemleri Sanayi", "Warmhaus", "Ewa", "2525 C 25 KW", "8699104832918", "2019", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "23.7", "23.7", "A", "", "88.4", "79.8", "", "62.3", "", "2", "", "", "104", "1", "2", "43", "5", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "", "", "0005", "", "A", "84", "XL", "92", "11", "79", "57.0", "88.3", "97.6", "", "", "", "", "95.8"]} -{"pcdb_id": 18903, "brand_name": "Worcester", "model_name": "Greenstar 2000", "model_qualifier": "GR2300iW 25 C LPG", "winter_efficiency_pct": 90.0, "summer_efficiency_pct": 90.3, "comparative_hot_water_efficiency_pct": 77.1, "output_kw_max": 20.0, "final_year_of_manufacture": null, "raw": ["018903", "020051", "0", "2021/Apr/28 09:50", "Bosch Thermotechnology Ltd", "Worcester", "Greenstar 2000", "GR2300iW 25 C LPG", "47-800-27", "2021", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "20", "20", "A", "", "90.0", "90.3", "", "77.1", "", "2", "0", "2", "104", "1", "2", "28", "3", "0", "", "", "", "0", "", "", "", "", "2", "6.981", "0.086", "0.003", "0.85226", "12.311", "0.104", "0.0", "0.84514", "0.00003", "0", "", "", "8305", "", "A", "84", "XL", "93", "11", "58", "55.0", "89.9", "98.9", "", "018820", "", "", "97.2"]} -{"pcdb_id": 18904, "brand_name": "Worcester", "model_name": "Greenstar 2000", "model_qualifier": "GR2300iW 30 C LPG", "winter_efficiency_pct": 90.0, "summer_efficiency_pct": 90.3, "comparative_hot_water_efficiency_pct": 76.1, "output_kw_max": 20.0, "final_year_of_manufacture": null, "raw": ["018904", "020051", "0", "2021/Apr/28 09:45", "Bosch Thermotechnology Ltd", "Worcester", "Greenstar 2000", "GR2300iW 30 C LPG", "47-800-29", "2021", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "20", "20", "A", "", "90.0", "90.3", "", "76.1", "", "2", "0", "2", "104", "1", "2", "28", "3", "0", "", "", "", "0", "", "", "", "", "2", "7.074", "0.083", "0.0045", "0.93294", "12.496", "0.104", "0.0", "0.92573", "0.00005", "0", "", "", "8305", "", "A", "84", "XL", "93", "11", "58", "55.0", "89.9", "98.9", "", "018821", "", "", "97.2"]} -{"pcdb_id": 18905, "brand_name": "Sapphire", "model_name": "Sapphire 28", "model_qualifier": "", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 81.1, "comparative_hot_water_efficiency_pct": 59.2, "output_kw_max": 28.0, "final_year_of_manufacture": null, "raw": ["018905", "020153", "0", "2021/Apr/27 10:27", "EOGB Energy Products ltd", "Sapphire", "Sapphire 28", "", "", "2021", "current", "4", "1", "1", "1", "0", "", "", "2", "2", "2", "28", "28", "A", "", "88.9", "81.1", "", "59.2", "", "2", "", "", "201", "1", "2", "117", "6.22", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "4015", "", "", "", "", "93", "27.1", "164", "49.4", "91.5", "96.8", "", "", "", "", "95.8"]} -{"pcdb_id": 18906, "brand_name": "Sapphire", "model_name": "Sapphire 23", "model_qualifier": "", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 80.9, "comparative_hot_water_efficiency_pct": 59.1, "output_kw_max": 23.0, "final_year_of_manufacture": null, "raw": ["018906", "020153", "0", "2021/May/10 09:22", "EOGB Energy Products ltd", "Sapphire", "Sapphire 23", "", "", "2021", "current", "4", "1", "1", "1", "0", "", "", "2", "2", "2", "23", "23", "A", "", "88.7", "80.9", "", "59.1", "", "2", "", "", "201", "1", "2", "133", "6", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "4015", "", "", "", "", "92", "27", "172", "49.0", "92.6", "95.9", "", "", "", "", "95.2"]} -{"pcdb_id": 18907, "brand_name": "Worcester", "model_name": "Greenstar 4000", "model_qualifier": "GR4700iW 30 C NG", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 87.6, "comparative_hot_water_efficiency_pct": 74.2, "output_kw_max": 24.0, "final_year_of_manufacture": null, "raw": ["018907", "020051", "0", "2021/Jun/15 14:05", "Bosch Thermotechnology Ltd", "Worcester", "Greenstar 4000", "GR4700iW 30 C NG", "47-800-32", "2021", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "A", "", "88.7", "87.6", "", "74.2", "", "2", "", "", "104", "1", "2", "38.8", "2.44", "0", "", "", "", "0", "", "", "", "", "2", "7.099", "0.109", "0.0004", "0.98328", "13.078", "0.134", "0.0004", "0.91574", "0.0", "0", "", "", "C305", "", "A", "85", "XL", "94", "13.1", "66", "61.0", "88.0", "98.6", "", "", "", "", "96.6"]} -{"pcdb_id": 18908, "brand_name": "Worcester", "model_name": "Greenstar 4000", "model_qualifier": "GR4700iW 25 C NG", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 88.2, "comparative_hot_water_efficiency_pct": 73.8, "output_kw_max": 24.0, "final_year_of_manufacture": null, "raw": ["018908", "020051", "0", "2021/Jun/15 14:06", "Bosch Thermotechnology Ltd", "Worcester", "Greenstar 4000", "GR4700iW 25 C NG", "47-800-30", "2021", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "A", "", "88.7", "88.2", "", "73.8", "", "2", "", "", "104", "1", "2", "38.8", "2.44", "0", "", "", "", "0", "", "", "", "", "2", "7.134", "0.11", "0.0008", "1.01462", "12.918", "0.134", "0.0004", "0.99421", "0.0", "0", "", "", "C305", "", "A", "85", "XL", "94", "13.1", "66", "61.0", "88.0", "98.6", "", "", "", "", "96.6"]} -{"pcdb_id": 18909, "brand_name": "Worcester", "model_name": "Greenstar 4000", "model_qualifier": "GR4700iW 24 S NG", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 24.0, "final_year_of_manufacture": null, "raw": ["018909", "020051", "0", "2021/Jun/11 17:28", "Bosch Thermotechnology Ltd", "Worcester", "Greenstar 4000", "GR4700iW 24 S NG", "41-800-15", "2021", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24", "24", "A", "", "88.7", "79.7", "", "58.2", "", "2", "", "", "102", "1", "2", "38", "2.44", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "C305", "", "", "", "", "94", "11.8", "62", "59.0", "88.0", "98.6", "", "", "", "", "96.6"]} -{"pcdb_id": 18910, "brand_name": "Worcester", "model_name": "Greenstar 4000", "model_qualifier": "GR4700iW 21 S NG", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 21.0, "final_year_of_manufacture": null, "raw": ["018910", "020051", "0", "2021/Jun/11 17:43", "Bosch Thermotechnology Ltd", "Worcester", "Greenstar 4000", "GR4700iW 21 S NG", "41-800-13", "2021", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "21", "21", "A", "", "88.9", "79.9", "", "58.4", "", "2", "", "", "102", "1", "2", "30", "2.44", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "C305", "", "", "", "", "94", "11.2", "56", "59.0", "88.1", "99.0", "", "", "", "", "96.9"]} -{"pcdb_id": 18911, "brand_name": "Worcester", "model_name": "Greenstar 4000", "model_qualifier": "GR4700iW 18 S NG", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 18.0, "final_year_of_manufacture": null, "raw": ["018911", "020051", "0", "2021/Jun/11 16:56", "Bosch Thermotechnology Ltd", "Worcester", "Greenstar 4000", "GR4700iW 18 S NG", "41-800-11", "2021", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18", "18", "A", "", "88.8", "79.8", "", "58.3", "", "2", "", "", "102", "1", "2", "27", "2.44", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "C305", "", "", "", "", "94", "11", "54", "59.0", "88.0", "98.8", "", "", "", "", "96.8"]} -{"pcdb_id": 18912, "brand_name": "Worcester", "model_name": "Greenstar 4000", "model_qualifier": "GR4700iW 15 S NG", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 15.0, "final_year_of_manufacture": null, "raw": ["018912", "020051", "0", "2021/Jun/11 16:46", "Bosch Thermotechnology Ltd", "Worcester", "Greenstar 4000", "GR4700iW 15 S NG", "41-800-09", "2021", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "15", "15", "A", "", "89.1", "80.1", "", "58.5", "", "2", "", "", "102", "1", "2", "31.3", "2.44", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "C305", "", "", "", "", "94", "11.3", "57", "59.0", "88.5", "99.3", "", "", "", "", "97.2"]} -{"pcdb_id": 18913, "brand_name": "Worcester", "model_name": "Greenstar 4000", "model_qualifier": "GR4700iW 12 S NG", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 12.0, "final_year_of_manufacture": null, "raw": ["018913", "020051", "0", "2021/Jun/11 16:42", "Bosch Thermotechnology Ltd", "Worcester", "Greenstar 4000", "GR4700iW 12 S NG", "41-800-07", "2021", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "12", "12", "A", "", "89.1", "80.1", "", "58.5", "", "2", "", "", "102", "1", "2", "22.8", "2.44", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "C305", "", "", "", "", "94", "10.6", "51", "59.0", "88.5", "99.5", "", "", "", "", "97.4"]} -{"pcdb_id": 18914, "brand_name": "E.C.A", "model_name": "FELiS FL 50 HM NG GB", "model_qualifier": "Condensing Boiler", "winter_efficiency_pct": 87.8, "summer_efficiency_pct": 78.8, "comparative_hot_water_efficiency_pct": 57.6, "output_kw_max": 45.6, "final_year_of_manufacture": null, "raw": ["018914", "020162", "0", "2021/Aug/05 09:49", "Emas Makina Sanayi AS", "E.C.A", "FELiS FL 50 HM NG GB", "Condensing Boiler", "41-814-41", "2021", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "45.6", "45.6", "A", "", "87.8", "78.8", "", "57.6", "", "2", "", "", "102", "1", "2", "75", "4", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "95", "16", "102", "411.0", "86.2", "97.1", "", "", "", "", "95.1"]} -{"pcdb_id": 18915, "brand_name": "E.C.A", "model_name": "FELiS FL 65 HM NG GB", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 66.0, "final_year_of_manufacture": null, "raw": ["018915", "020162", "0", "2021/Oct/13 09:09", "Emas Makina Sanayi AS", "E.C.A", "FELiS FL 65 HM NG GB", "", "41-814-42", "2021", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "66", "66", "A", "", "88.1", "79.1", "", "57.8", "", "2", "", "", "102", "1", "2", "115", "4", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "95", "22", "138", "939.0", "87.4", "97.3", "", "", "", "", "95.4"]} -{"pcdb_id": 18916, "brand_name": "Worcester", "model_name": "Greenstar 4000", "model_qualifier": "GR4700iW 30 C LPG", "winter_efficiency_pct": 89.8, "summer_efficiency_pct": 89.4, "comparative_hot_water_efficiency_pct": 75.1, "output_kw_max": 24.0, "final_year_of_manufacture": null, "raw": ["018916", "020051", "0", "2021/Oct/12 13:17", "Bosch Thermotechnology Ltd", "Worcester", "Greenstar 4000", "GR4700iW 30 C LPG", "47-800-33", "2021", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "A", "", "89.8", "89.4", "", "75.1", "", "2", "0", "2", "104", "1", "2", "39", "2", "0", "", "", "", "0", "", "", "", "", "2", "7.168", "0.108", "0.0", "1.04497", "13.158", "0.131", "0.0004", "0.97381", "0.0", "0", "", "", "C305", "", "A", "85", "XL", "94", "13", "63", "61.0", "89.7", "98.5", "", "", "", "", "96.8"]} -{"pcdb_id": 18917, "brand_name": "Worcester", "model_name": "Greenstar 4000", "model_qualifier": "GR4700iW 25 C LPG", "winter_efficiency_pct": 89.8, "summer_efficiency_pct": 90.3, "comparative_hot_water_efficiency_pct": 73.3, "output_kw_max": 24.0, "final_year_of_manufacture": null, "raw": ["018917", "020051", "0", "2021/Oct/12 13:08", "Bosch Thermotechnology Ltd", "Worcester", "Greenstar 4000", "GR4700iW 25 C LPG", "47-800-32", "2021", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "A", "", "89.8", "90.3", "", "73.3", "", "2", "0", "2", "104", "1", "2", "38.8", "2.44", "0", "", "", "", "0", "", "", "", "", "2", "7.343", "0.109", "0.0008", "1.20857", "13.262", "0.132", "0.0004", "1.20588", "0.0", "0", "", "", "C305", "", "A", "85", "XL", "94", "13.1", "66", "61.0", "89.7", "98.5", "", "", "", "", "96.8"]} -{"pcdb_id": 18918, "brand_name": "Worcester", "model_name": "Greenstar 4000", "model_qualifier": "GR4700iW 24 S LPG", "winter_efficiency_pct": 89.8, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 59.0, "output_kw_max": 24.0, "final_year_of_manufacture": null, "raw": ["018918", "020051", "0", "2021/Oct/12 13:00", "Bosch Thermotechnology Ltd", "Worcester", "Greenstar 4000", "GR4700iW 24 S LPG", "41-800-16", "2021", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "24", "24", "A", "", "89.8", "80.8", "", "59.0", "", "2", "0", "2", "102", "1", "2", "38", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "C305", "", "", "", "", "94", "12", "60", "59.0", "89.7", "98.5", "", "", "", "", "96.8"]} -{"pcdb_id": 18919, "brand_name": "Worcester", "model_name": "Greenstar 4000", "model_qualifier": "GR4700iW 21 S LPG", "winter_efficiency_pct": 89.9, "summer_efficiency_pct": 80.9, "comparative_hot_water_efficiency_pct": 59.1, "output_kw_max": 21.0, "final_year_of_manufacture": null, "raw": ["018919", "020051", "0", "2021/Oct/12 12:24", "Bosch Thermotechnology Ltd", "Worcester", "Greenstar 4000", "GR4700iW 21 S LPG", "41-800-14", "2021", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "21", "21", "A", "", "89.9", "80.9", "", "59.1", "", "2", "0", "2", "102", "1", "2", "30", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "C305", "", "", "", "", "94", "11", "53", "59.0", "90.0", "98.5", "", "", "", "", "96.9"]} -{"pcdb_id": 18920, "brand_name": "Worcester", "model_name": "Greenstar 4000", "model_qualifier": "GR4700iW 18 S LPG", "winter_efficiency_pct": 89.9, "summer_efficiency_pct": 80.9, "comparative_hot_water_efficiency_pct": 59.1, "output_kw_max": 18.0, "final_year_of_manufacture": null, "raw": ["018920", "020051", "0", "2021/Oct/12 12:06", "Bosch Thermotechnology Ltd", "Worcester", "Greenstar 4000", "GR4700iW 18 S LPG", "41-800-12", "2021", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "18", "18", "A", "", "89.9", "80.9", "", "59.1", "", "2", "0", "2", "102", "1", "2", "27", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "C305", "", "", "", "", "94", "11", "52", "59.0", "90.0", "98.7", "", "", "", "", "97.1"]} -{"pcdb_id": 18921, "brand_name": "Worcester", "model_name": "Greenstar 4000", "model_qualifier": "GR4700iW 15 S LPG", "winter_efficiency_pct": 90.0, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 59.2, "output_kw_max": 15.0, "final_year_of_manufacture": null, "raw": ["018921", "020051", "0", "2021/Oct/12 12:06", "Bosch Thermotechnology Ltd", "Worcester", "Greenstar 4000", "GR4700iW 15 S LPG", "41-800-10", "2021", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "15", "15", "A", "", "90.0", "81.0", "", "59.2", "", "2", "0", "2", "102", "1", "2", "31", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "C305", "", "", "", "", "94", "11", "54", "59.0", "89.8", "98.9", "", "", "", "", "97.2"]} -{"pcdb_id": 18922, "brand_name": "Worcester", "model_name": "Greenstar 4000", "model_qualifier": "GR4700iW 12 S LPG", "winter_efficiency_pct": 90.0, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 59.2, "output_kw_max": 12.0, "final_year_of_manufacture": null, "raw": ["018922", "020051", "0", "2021/Oct/12 11:35", "Bosch Thermotechnology Ltd", "Worcester", "Greenstar 4000", "GR4700iW 12 S LPG", "41-800-08", "2021", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "12", "12", "A", "", "90.0", "81.0", "", "59.2", "", "2", "0", "2", "102", "1", "2", "23", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "C305", "", "", "", "", "94", "11", "49", "59.0", "90.0", "99.0", "", "", "", "", "97.3"]} -{"pcdb_id": 18923, "brand_name": "Viessmann", "model_name": "VITODENS 200-W", "model_qualifier": "B2HF-11", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 10.0, "final_year_of_manufacture": null, "raw": ["018923", "020094", "0", "2021/Nov/26 14:42", "Viessmann Ltd", "Viessmann", "VITODENS 200-W", "B2HF-11", "B2HF", "2020", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "10", "10", "A", "", "88.3", "79.3", "", "58.0", "", "2", "", "", "102", "1", "2", "16", "4.7", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "92", "15", "70", "52.5", "88.2", "97.6", "", "", "", "", "95.8"]} -{"pcdb_id": 18924, "brand_name": "Viessmann", "model_name": "VITODENS 200-W", "model_qualifier": "B2HF-11", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 10.0, "final_year_of_manufacture": null, "raw": ["018924", "020094", "0", "2021/Nov/26 14:43", "Viessmann Ltd", "Viessmann", "VITODENS 200-W", "B2HF-11", "B2HF11", "2020", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "10", "10", "A", "", "89.2", "80.2", "", "58.6", "", "2", "0", "2", "102", "1", "2", "16", "4.7", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "92", "15", "70", "52.5", "90.0", "97.0", "", "", "", "", "95.7"]} -{"pcdb_id": 18925, "brand_name": "Viessmann", "model_name": "VITODENS 200-W", "model_qualifier": "B2HF-19", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 18.0, "final_year_of_manufacture": null, "raw": ["018925", "020094", "0", "2021/Nov/26 14:45", "Viessmann Ltd", "Viessmann", "VITODENS 200-W", "B2HF-19", "B2HF19", "2020", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18", "18", "A", "", "88.5", "79.5", "", "58.0", "", "2", "", "", "102", "1", "2", "17", "4.7", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "93", "15", "71", "52.5", "88.5", "97.8", "", "", "", "", "96.0"]} -{"pcdb_id": 18926, "brand_name": "Viessmann", "model_name": "VITODENS 200-W", "model_qualifier": "B2HF-19", "winter_efficiency_pct": 89.5, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 58.8, "output_kw_max": 18.0, "final_year_of_manufacture": null, "raw": ["018926", "020094", "0", "2021/Nov/26 14:48", "Viessmann Ltd", "Viessmann", "VITODENS 200-W", "B2HF-19", "B2HF19", "2020", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "18", "18", "A", "", "89.5", "80.5", "", "58.8", "", "2", "0", "2", "102", "1", "2", "17", "4.7", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "93", "15", "71", "52.5", "90.2", "97.4", "", "", "", "", "96.1"]} -{"pcdb_id": 18927, "brand_name": "Viessmann", "model_name": "VITODENS 200-W", "model_qualifier": "B2HF-25", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 23.0, "final_year_of_manufacture": null, "raw": ["018927", "020094", "0", "2021/Nov/26 14:50", "Viessmann Ltd", "Viessmann", "VITODENS 200-W", "B2HF-25", "B2HF25", "2020", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "23", "23", "A", "", "88.6", "79.6", "", "58.2", "", "2", "", "", "102", "1", "2", "19", "4.7", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "94", "16", "74", "52.5", "88.5", "98.2", "", "", "", "", "96.4"]} -{"pcdb_id": 18928, "brand_name": "Viessmann", "model_name": "VITODENS 200-W", "model_qualifier": "B2HF-25", "winter_efficiency_pct": 89.5, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 58.8, "output_kw_max": 23.0, "final_year_of_manufacture": null, "raw": ["018928", "020094", "0", "2021/Nov/26 14:51", "Viessmann Ltd", "Viessmann", "VITODENS 200-W", "B2HF-25", "B2HF25", "2020", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "23", "23", "A", "", "89.5", "80.5", "", "58.8", "", "2", "0", "2", "102", "1", "2", "19", "4.7", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "94", "16", "74", "52.5", "90.3", "97.6", "", "", "", "", "96.2"]} -{"pcdb_id": 18929, "brand_name": "Viessmann", "model_name": "VITODENS 200-W", "model_qualifier": "B2HF-32", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 29.0, "final_year_of_manufacture": null, "raw": ["018929", "020094", "0", "2021/Nov/26 14:56", "Viessmann Ltd", "Viessmann", "VITODENS 200-W", "B2HF-32", "B2HF32", "2020", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "29", "29", "A", "", "88.5", "79.5", "", "58.1", "", "2", "", "", "102", "1", "2", "21", "4.7", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "94", "16", "75", "52.5", "88.2", "98.0", "", "", "", "", "96.2"]} -{"pcdb_id": 18930, "brand_name": "Viessmann", "model_name": "VITODENS 200-W", "model_qualifier": "B2HF-32", "winter_efficiency_pct": 89.6, "summer_efficiency_pct": 80.6, "comparative_hot_water_efficiency_pct": 58.9, "output_kw_max": 29.0, "final_year_of_manufacture": null, "raw": ["018930", "020094", "0", "2021/Nov/26 14:57", "Viessmann Ltd", "Viessmann", "VITODENS 200-W", "B2HF-32", "B2HF32", "2020", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "29", "29", "A", "", "89.6", "80.6", "", "58.9", "", "2", "0", "2", "102", "1", "2", "21", "4.7", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "94", "16", "75", "52.5", "90.1", "97.9", "", "", "", "", "96.4"]} -{"pcdb_id": 18931, "brand_name": "Viessmann", "model_name": "VITODENS 200-W", "model_qualifier": "B2KF-25", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 87.6, "comparative_hot_water_efficiency_pct": 70.6, "output_kw_max": 23.0, "final_year_of_manufacture": null, "raw": ["018931", "020094", "0", "2021/Nov/26 14:26", "Viessmann Ltd", "Viessmann", "VITODENS 200-W", "B2KF-25", "B2KF25", "2020", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "23", "23", "A", "", "88.6", "87.6", "", "70.6", "", "2", "", "", "104", "1", "2", "19", "4.7", "0", "", "", "", "0", "", "", "", "", "2", "7.456", "0.159", "0.0049", "1.31296", "13.425", "0.179", "0.0017", "1.22773", "0.00003", "0", "", "", "0005", "", "A", "82", "XL", "94", "16", "74", "52.5", "88.5", "98.2", "", "", "", "", "96.4"]} -{"pcdb_id": 18932, "brand_name": "Viessmann", "model_name": "VITODENS 200-W", "model_qualifier": "B2KF-25", "winter_efficiency_pct": 89.5, "summer_efficiency_pct": 89.2, "comparative_hot_water_efficiency_pct": 72.3, "output_kw_max": 23.0, "final_year_of_manufacture": null, "raw": ["018932", "020094", "0", "2021/Nov/26 14:25", "Viessmann Ltd", "Viessmann", "VITODENS 200-W", "B2KF-25", "B2KF25", "2020", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "23", "23", "A", "", "89.5", "89.2", "", "72.3", "", "2", "0", "2", "104", "1", "2", "19", "4.7", "0", "", "", "", "0", "", "", "", "", "2", "7.444", "0.158", "0.0031", "1.30705", "13.443", "0.178", "0.0018", "1.20558", "0.00001", "0", "", "", "0005", "", "A", "82", "XL", "94", "16", "74", "52.5", "90.3", "97.6", "", "", "", "", "96.2"]} -{"pcdb_id": 18933, "brand_name": "Viessmann", "model_name": "VITODENS 200-W", "model_qualifier": "B2KF-32", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 73.3, "output_kw_max": 29.0, "final_year_of_manufacture": null, "raw": ["018933", "020094", "0", "2022/May/16 20:56", "Viessmann Ltd", "Viessmann", "VITODENS 200-W", "B2KF-32", "B2KF32", "2020", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "29", "29", "A", "", "88.5", "79.2", "", "73.3", "", "2", "", "", "104", "1", "2", "21", "4.7", "0", "", "", "", "0", "", "", "", "", "2", "7.189", "0.176", "0.0006", "1.07341", "13.802", "0.2", "0.0009", "0.34805", "0.0", "0", "", "", "0005", "", "A", "82", "XL", "94", "16", "75", "52.5", "88.2", "98.0", "", "", "", "", "96.2"]} -{"pcdb_id": 18934, "brand_name": "Viessmann", "model_name": "VITODENS 200-W", "model_qualifier": "B2KF-32", "winter_efficiency_pct": 89.6, "summer_efficiency_pct": 81.7, "comparative_hot_water_efficiency_pct": 72.9, "output_kw_max": 29.0, "final_year_of_manufacture": null, "raw": ["018934", "020094", "0", "2021/Nov/26 14:29", "Viessmann Ltd", "Viessmann", "VITODENS 200-W", "B2KF-32", "B2KF32", "2020", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "29", "29", "A", "", "89.6", "81.7", "", "72.9", "", "2", "0", "2", "104", "1", "2", "21", "4.7", "0", "", "", "", "0", "", "", "", "", "2", "7.388", "0.17", "0.0025", "1.25178", "13.926", "0.2", "0.0004", "0.56403", "0.00002", "0", "", "", "0005", "", "A", "82", "XL", "94", "16", "75", "52.5", "90.1", "97.9", "", "", "", "", "96.4"]} -{"pcdb_id": 18935, "brand_name": "Viessmann", "model_name": "VITODENS 222-F", "model_qualifier": "B2TF-19", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 88.2, "comparative_hot_water_efficiency_pct": 59.4, "output_kw_max": 18.0, "final_year_of_manufacture": null, "raw": ["018935", "020094", "0", "2021/Nov/23 16:01", "Viessmann Ltd", "Viessmann", "VITODENS 222-F", "B2TF-19", "B2TF19", "2020", "current", "1", "1", "1", "2", "0", "", "", "2", "2", "2", "18", "18", "A", "", "88.5", "88.2", "", "59.4", "", "2", "", "", "106", "1", "2", "17", "4.7", "2", "2", "0", "100", "0", "", "2", "", "", "2", "8.873", "0.217", "0.0001", "2.70647", "14.519", "0.247", "0.0", "2.66659", "0.0", "", "", "", "0005", "", "A", "80", "XL", "93", "15", "71", "69.1", "88.5", "97.8", "", "", "", "", "96.0"]} -{"pcdb_id": 18936, "brand_name": "Viessmann", "model_name": "VITODENS 222F", "model_qualifier": "B2TF-19", "winter_efficiency_pct": 89.5, "summer_efficiency_pct": 90.3, "comparative_hot_water_efficiency_pct": 60.3, "output_kw_max": 18.0, "final_year_of_manufacture": null, "raw": ["018936", "020094", "0", "2021/Nov/23 16:07", "Viessmann Ltd", "Viessmann", "VITODENS 222F", "B2TF-19", "B2TF19", "2020", "current", "2", "1", "1", "2", "0", "", "", "2", "2", "2", "18", "18", "A", "", "89.5", "90.3", "", "60.3", "", "2", "0", "2", "106", "1", "2", "17", "4.7", "2", "2", "0", "100", "0", "", "2", "", "", "2", "8.934", "0.206", "0.0001", "2.75679", "14.806", "0.253", "0.0", "2.73891", "0.0", "", "", "", "0005", "", "A", "80", "XL", "93", "15", "71", "69.1", "90.2", "97.4", "", "", "", "", "96.1"]} -{"pcdb_id": 18937, "brand_name": "Viessmann", "model_name": "VITODENS 222-F", "model_qualifier": "B2TF-25", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 86.9, "comparative_hot_water_efficiency_pct": 60.9, "output_kw_max": 23.0, "final_year_of_manufacture": null, "raw": ["018937", "020094", "0", "2021/Nov/23 16:18", "Viessmann Ltd", "Viessmann", "VITODENS 222-F", "B2TF-25", "B2TF25", "2020", "current", "1", "1", "1", "2", "0", "", "", "2", "2", "2", "23", "23", "A", "", "88.7", "86.9", "", "60.9", "", "2", "", "", "106", "1", "2", "19", "4.7", "2", "2", "0", "100", "0", "", "2", "", "", "2", "8.644", "0.187", "0.0003", "2.48488", "14.665", "0.215", "0.0001", "2.32738", "0.0", "", "", "", "0005", "", "A", "80", "XL", "93", "16", "74", "69.1", "88.5", "98.4", "", "", "", "", "96.5"]} -{"pcdb_id": 18938, "brand_name": "Viessmann", "model_name": "VITODENS 222-F", "model_qualifier": "B2TF-25", "winter_efficiency_pct": 89.5, "summer_efficiency_pct": 90.3, "comparative_hot_water_efficiency_pct": 61.9, "output_kw_max": 23.0, "final_year_of_manufacture": null, "raw": ["018938", "020094", "0", "2021/Nov/11 14:52", "Viessmann Ltd", "Viessmann", "VITODENS 222-F", "B2TF-25", "B2TF25", "2020", "current", "2", "1", "1", "2", "0", "", "", "2", "2", "2", "23", "23", "A", "", "89.5", "90.3", "", "61.9", "", "2", "0", "2", "106", "1", "2", "19", "4.7", "2", "2", "0", "100", "0", "", "2", "", "", "2", "8.696", "0.188", "0.0003", "2.52931", "14.616", "0.214", "0.0002", "2.50906", "0.0", "", "", "", "0005", "", "A", "80", "XL", "94", "16", "74", "69.1", "90.3", "97.6", "", "", "", "", "96.2"]} -{"pcdb_id": 18939, "brand_name": "Viessmann", "model_name": "VITODENS 222-F", "model_qualifier": "B2TF-32", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 84.1, "comparative_hot_water_efficiency_pct": 63.2, "output_kw_max": 29.0, "final_year_of_manufacture": null, "raw": ["018939", "020094", "0", "2021/Nov/23 16:18", "Viessmann Ltd", "Viessmann", "VITODENS 222-F", "B2TF-32", "B2TF32", "2020", "current", "1", "1", "1", "2", "0", "", "", "2", "2", "2", "29", "29", "A", "", "88.5", "84.1", "", "63.2", "", "2", "", "", "106", "1", "2", "21", "4.7", "2", "2", "0", "100", "0", "", "2", "", "", "2", "8.33", "0.174", "0.0005", "2.17289", "14.55", "0.205", "0.0002", "1.77651", "0.0", "", "", "", "0005", "", "A", "80", "XL", "94", "16", "75", "69.1", "88.2", "98.0", "", "", "", "", "96.2"]} -{"pcdb_id": 18940, "brand_name": "Viessmann", "model_name": "VITODENS 222-F", "model_qualifier": "B2TF-32", "winter_efficiency_pct": 89.6, "summer_efficiency_pct": 80.6, "comparative_hot_water_efficiency_pct": 63.6, "output_kw_max": 29.0, "final_year_of_manufacture": null, "raw": ["018940", "020094", "0", "2021/Nov/23 16:21", "Viessmann Ltd", "Viessmann", "VITODENS 222-F", "B2TF-32", "B2TF32", "2020", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "29", "29", "A", "", "89.6", "80.6", "", "63.6", "", "2", "0", "2", "106", "1", "2", "21", "4.7", "1", "2", "0", "100", "0", "", "2", "", "", "2", "8.46", "0.175", "0.0005", "2.2953", "15.097", "0.2", "0.0002", "1.40973", "0.0", "", "", "", "0005", "", "A", "80", "XL", "94", "16", "75", "69.1", "90.1", "97.9", "", "", "", "", "96.4"]} -{"pcdb_id": 18941, "brand_name": "Viessmann", "model_name": "VITODENS 100-W", "model_qualifier": "B1KF-26", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 88.2, "comparative_hot_water_efficiency_pct": 69.8, "output_kw_max": 23.0, "final_year_of_manufacture": null, "raw": ["018941", "020094", "0", "2022/Jan/14 15:41", "Viessmann Ltd", "Viessmann", "VITODENS 100-W", "B1KF-26", "", "2021", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "23", "23", "A", "", "88.7", "88.2", "", "69.8", "", "2", "", "", "104", "1", "2", "18", "3.8", "0", "", "", "", "0", "", "", "", "", "2", "7.541", "0.157", "0.0011", "1.4097", "13.475", "0.175", "0.0013", "1.3832", "0.0", "1", "1", "", "00020005", "", "A", "82", "XL", "94", "15", "66", "57.3", "88.2", "98.5", "", "", "", "", "96.5"]} -{"pcdb_id": 18942, "brand_name": "Viessmann", "model_name": "VITODENS 100-W", "model_qualifier": "B1KF-35", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 85.2, "comparative_hot_water_efficiency_pct": 70.1, "output_kw_max": 29.3, "final_year_of_manufacture": null, "raw": ["018942", "020094", "0", "2022/Jan/14 15:41", "Viessmann Ltd", "Viessmann", "VITODENS 100-W", "B1KF-35", "", "2021", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "29.3", "29.3", "A", "", "88.5", "85.2", "", "70.1", "", "2", "", "", "104", "1", "2", "21", "3.8", "0", "", "", "", "0", "", "", "", "", "2", "7.514", "0.2", "0.001", "1.37662", "13.657", "0.224", "0.0007", "1.11648", "0.0", "1", "1", "", "00020005", "", "A", "82", "XL", "94", "16", "70", "57.3", "87.9", "98.2", "", "", "", "", "96.3"]} -{"pcdb_id": 18943, "brand_name": "Viessmann", "model_name": "VITODENS 100-W", "model_qualifier": "B1KF-26", "winter_efficiency_pct": 89.6, "summer_efficiency_pct": 90.3, "comparative_hot_water_efficiency_pct": 70.2, "output_kw_max": 23.0, "final_year_of_manufacture": null, "raw": ["018943", "020094", "0", "2022/Jan/14 15:44", "Viessmann Ltd", "Viessmann", "VITODENS 100-W", "B1KF-26", "", "2021", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "23", "23", "A", "", "89.6", "90.3", "", "70.2", "", "2", "0", "2", "104", "1", "2", "18", "3.8", "0", "", "", "", "0", "", "", "", "", "2", "7.67", "0.16", "0.0027", "1.507", "13.604", "0.176", "0.0023", "1.50921", "0.0", "1", "1", "", "00020005", "", "A", "82", "XL", "94", "15", "66", "57.3", "89.5", "98.1", "", "", "", "", "96.5"]} -{"pcdb_id": 18944, "brand_name": "Viessmann", "model_name": "VITODENS 100-W", "model_qualifier": "B1KF-35", "winter_efficiency_pct": 89.8, "summer_efficiency_pct": 89.2, "comparative_hot_water_efficiency_pct": 69.6, "output_kw_max": 29.3, "final_year_of_manufacture": null, "raw": ["018944", "020094", "0", "2022/Jan/14 15:45", "Viessmann Ltd", "Viessmann", "VITODENS 100-W", "B1KF-35", "", "2021", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "29.3", "29.3", "A", "", "89.8", "89.2", "", "69.6", "", "2", "0", "2", "104", "1", "2", "21", "3.8", "0", "", "", "", "0", "", "", "", "", "2", "7.729", "0.202", "0.0049", "1.56598", "13.701", "0.227", "0.0003", "1.46408", "0.00005", "1", "1", "", "00020005", "", "A", "82", "XL", "94", "16", "70", "57.3", "90.1", "98.3", "", "", "", "", "96.7"]} -{"pcdb_id": 18945, "brand_name": "Viessmann", "model_name": "VITODENS 100-W", "model_qualifier": "B1KF-30", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 88.1, "comparative_hot_water_efficiency_pct": 69.8, "output_kw_max": 23.0, "final_year_of_manufacture": null, "raw": ["018945", "020094", "0", "2022/Jan/14 15:47", "Viessmann Ltd", "Viessmann", "VITODENS 100-W", "B1KF-30", "", "2021", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "23", "23", "A", "", "88.7", "88.1", "", "69.8", "", "2", "", "", "104", "1", "2", "18", "3.8", "0", "", "", "", "0", "", "", "", "", "2", "7.543", "0.16", "0.0025", "1.40315", "13.481", "0.177", "0.0007", "1.36515", "0.00002", "1", "1", "", "00020005", "", "A", "82", "XL", "94", "15", "66", "57.3", "88.2", "98.5", "", "", "", "", "96.5"]} -{"pcdb_id": 18946, "brand_name": "Viessmann", "model_name": "VITODENS 100-W", "model_qualifier": "B1KF-30", "winter_efficiency_pct": 89.6, "summer_efficiency_pct": 90.3, "comparative_hot_water_efficiency_pct": 70.8, "output_kw_max": 23.0, "final_year_of_manufacture": null, "raw": ["018946", "020094", "0", "2022/Jan/14 15:49", "Viessmann Ltd", "Viessmann", "VITODENS 100-W", "B1KF-30", "", "2021", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "23", "23", "A", "", "89.6", "90.3", "", "70.8", "", "2", "0", "2", "104", "1", "2", "18", "3.8", "0", "", "", "", "0", "", "", "", "", "2", "7.601", "0.16", "0.001", "1.44788", "13.501", "0.178", "0.0012", "1.45255", "0.0", "1", "1", "", "00020005", "", "A", "82", "XL", "94", "15", "66", "57.3", "89.4", "98.1", "", "", "", "", "96.4"]} -{"pcdb_id": 18947, "brand_name": "Viessmann", "model_name": "VITODENS 100-W", "model_qualifier": "B1KF-30-M", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 88.1, "comparative_hot_water_efficiency_pct": 69.8, "output_kw_max": 23.0, "final_year_of_manufacture": null, "raw": ["018947", "020094", "0", "2022/Jan/14 15:50", "Viessmann Ltd", "Viessmann", "VITODENS 100-W", "B1KF-30-M", "", "2021", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "23", "23", "A", "", "88.7", "88.1", "", "69.8", "", "2", "", "", "104", "1", "2", "18", "3.8", "0", "", "", "", "0", "", "", "", "", "2", "7.543", "0.16", "0.0025", "1.40315", "13.481", "0.177", "0.0007", "1.36515", "0.00002", "1", "1", "", "00020005", "", "A", "82", "XL", "94", "15", "66", "57.3", "88.2", "98.5", "", "", "", "", "96.5"]} -{"pcdb_id": 18948, "brand_name": "Viessmann", "model_name": "VITODENS 100-W", "model_qualifier": "B1HF-11", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 10.1, "final_year_of_manufacture": null, "raw": ["018948", "020094", "0", "2022/Jan/14 15:56", "Viessmann Ltd", "Viessmann", "VITODENS 100-W", "B1HF-11", "", "2021", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "10.1", "10.1", "A", "", "88.8", "79.8", "", "58.3", "", "2", "", "", "102", "1", "2", "17", "3.8", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "00020005", "", "", "", "", "93", "15", "65", "57.3", "88.4", "98.7", "", "", "", "", "96.7"]} -{"pcdb_id": 18949, "brand_name": "Viessmann", "model_name": "VITODENS 100-W", "model_qualifier": "B1HF-11", "winter_efficiency_pct": 89.7, "summer_efficiency_pct": 80.7, "comparative_hot_water_efficiency_pct": 59.0, "output_kw_max": 10.1, "final_year_of_manufacture": null, "raw": ["018949", "020094", "0", "2022/Jan/14 15:57", "Viessmann Ltd", "Viessmann", "VITODENS 100-W", "B1HF-11", "", "2021", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "10.1", "10.1", "A", "", "89.7", "80.7", "", "59.0", "", "2", "0", "2", "102", "1", "2", "17", "3.8", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "00020005", "", "", "", "", "93", "15", "65", "57.3", "90.1", "98.2", "", "", "", "", "96.6"]} -{"pcdb_id": 18950, "brand_name": "Viessmann", "model_name": "VITODENS 100-W", "model_qualifier": "B1HF-11-M", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 10.1, "final_year_of_manufacture": null, "raw": ["018950", "020094", "0", "2022/Jan/14 15:58", "Viessmann Ltd", "Viessmann", "VITODENS 100-W", "B1HF-11-M", "", "2021", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "10.1", "10.1", "A", "", "88.8", "79.8", "", "58.3", "", "2", "", "", "102", "1", "2", "17", "3.8", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "00020005", "", "", "", "", "93", "15", "65", "57.3", "88.4", "98.7", "", "", "", "", "96.7"]} -{"pcdb_id": 18951, "brand_name": "Viessmann", "model_name": "VITODENS 100-W", "model_qualifier": "B1HF-19", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 17.5, "final_year_of_manufacture": null, "raw": ["018951", "020094", "0", "2022/Jan/14 16:00", "Viessmann Ltd", "Viessmann", "VITODENS 100-W", "B1HF-19", "", "2021", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "17.5", "17.5", "A", "", "88.8", "79.8", "", "58.3", "", "2", "", "", "102", "1", "2", "17", "3.8", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "00020005", "", "", "", "", "93", "14", "63", "57.3", "88.3", "98.7", "", "", "", "", "96.7"]} -{"pcdb_id": 18952, "brand_name": "Viessmann", "model_name": "VITODENS 100-W", "model_qualifier": "B1HF-25", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 23.0, "final_year_of_manufacture": null, "raw": ["018952", "020094", "0", "2022/Jan/14 16:08", "Viessmann Ltd", "Viessmann", "VITODENS 100-W", "B1HF-25", "", "2021", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "23", "23", "A", "", "88.7", "79.7", "", "58.2", "", "2", "", "", "102", "1", "2", "18", "3.8", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "00020005", "", "", "", "", "94", "15", "66", "57.3", "88.2", "98.5", "", "", "", "", "96.5"]} -{"pcdb_id": 18953, "brand_name": "Viessmann", "model_name": "VITODENS 100-W", "model_qualifier": "B1HF-25", "winter_efficiency_pct": 89.6, "summer_efficiency_pct": 80.6, "comparative_hot_water_efficiency_pct": 58.9, "output_kw_max": 23.0, "final_year_of_manufacture": null, "raw": ["018953", "020094", "0", "2022/Jan/14 16:10", "Viessmann Ltd", "Viessmann", "VITODENS 100-W", "B1HF-25", "", "2021", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "23", "23", "A", "", "89.6", "80.6", "", "58.9", "", "2", "0", "2", "102", "1", "2", "18", "3.8", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "00020005", "", "", "", "", "94", "15", "66", "57.3", "89.5", "98.1", "", "", "", "", "96.5"]} -{"pcdb_id": 18954, "brand_name": "Viessmann", "model_name": "VITODENS 100-W", "model_qualifier": "B1HF-32", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 29.3, "final_year_of_manufacture": null, "raw": ["018954", "020094", "0", "2022/Jan/14 16:12", "Viessmann Ltd", "Viessmann", "VITODENS 100-W", "B1HF-32", "", "2021", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "29.3", "29.3", "A", "", "88.5", "79.5", "", "58.1", "", "2", "", "", "102", "1", "2", "21", "3.8", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "00020005", "", "", "", "", "94", "16", "70", "57.3", "87.9", "98.2", "", "", "", "", "96.3"]} -{"pcdb_id": 18955, "brand_name": "Viessmann", "model_name": "VITODENS 100-W", "model_qualifier": "B1HF-32", "winter_efficiency_pct": 89.8, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 59.0, "output_kw_max": 29.3, "final_year_of_manufacture": null, "raw": ["018955", "020094", "0", "2022/Jan/14 16:13", "Viessmann Ltd", "Viessmann", "VITODENS 100-W", "B1HF-32", "", "2021", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "29.3", "29.3", "A", "", "89.8", "80.8", "", "59.0", "", "2", "0", "2", "102", "1", "2", "21", "3.8", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "00020005", "", "", "", "", "94", "16", "70", "57.3", "90.1", "98.3", "", "", "", "", "96.7"]} -{"pcdb_id": 18956, "brand_name": "Viessmann", "model_name": "VITODENS 111-W", "model_qualifier": "B1LF-25", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 87.7, "comparative_hot_water_efficiency_pct": 60.3, "output_kw_max": 23.0, "final_year_of_manufacture": null, "raw": ["018956", "020094", "0", "2022/Jan/24 12:25", "Viessmann Ltd", "Viessmann", "VITODENS 111-W", "B1LF-25", "", "2021", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "23", "23", "A", "", "88.7", "87.7", "", "60.3", "", "2", "", "", "106", "1", "2", "18", "3.8", "2", "2", "0", "46", "0", "", "2", "", "", "2", "8.733", "0.18", "0.0008", "2.55917", "14.699", "0.203", "0.0004", "2.48557", "0.0", "", "", "", "00020005", "", "A", "80", "XL", "94", "15", "66", "76.3", "88.2", "98.5", "", "", "", "", "96.5"]} -{"pcdb_id": 18957, "brand_name": "Viessmann", "model_name": "VITODENS 111-W", "model_qualifier": "B1LF-25", "winter_efficiency_pct": 89.6, "summer_efficiency_pct": 87.1, "comparative_hot_water_efficiency_pct": 61.3, "output_kw_max": 23.0, "final_year_of_manufacture": null, "raw": ["018957", "020094", "0", "2022/Jan/24 12:26", "Viessmann Ltd", "Viessmann", "VITODENS 111-W", "B1LF-25", "", "2021", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "23", "23", "A", "", "89.6", "87.1", "", "61.3", "", "2", "0", "2", "106", "1", "2", "18", "3.8", "2", "2", "0", "46", "0", "", "2", "", "", "2", "8.779", "0.175", "0.0006", "2.58424", "14.924", "0.199", "0.0004", "2.28751", "0.0", "", "", "", "00020005", "", "A", "80", "XL", "94", "15", "66", "76.3", "89.5", "98.1", "", "", "", "", "96.5"]} -{"pcdb_id": 18958, "brand_name": "Viessmann", "model_name": "VITODENS 111-W", "model_qualifier": "B1LF-M-25", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 87.7, "comparative_hot_water_efficiency_pct": 60.3, "output_kw_max": 23.0, "final_year_of_manufacture": null, "raw": ["018958", "020094", "0", "2022/Jan/24 12:26", "Viessmann Ltd", "Viessmann", "VITODENS 111-W", "B1LF-M-25", "", "2021", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "23", "23", "A", "", "88.7", "87.7", "", "60.3", "", "2", "", "", "106", "1", "2", "18", "3.8", "2", "2", "0", "46", "0", "", "2", "", "", "2", "8.733", "0.18", "0.0008", "2.55917", "14.699", "0.203", "0.0004", "2.48557", "0.0", "", "", "", "00020005", "", "A", "80", "XL", "94", "15", "66", "76.3", "88.2", "98.5", "", "", "", "", "96.5"]} -{"pcdb_id": 18959, "brand_name": "Viessmann", "model_name": "VITODENS 111-W", "model_qualifier": "B1LF-32", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 88.2, "comparative_hot_water_efficiency_pct": 61.8, "output_kw_max": 29.3, "final_year_of_manufacture": null, "raw": ["018959", "020094", "0", "2022/Jan/24 12:26", "Viessmann Ltd", "Viessmann", "VITODENS 111-W", "B1LF-32", "", "2021", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "29.3", "29.3", "A", "", "88.5", "88.2", "", "61.8", "", "2", "", "", "106", "1", "2", "21", "3.8", "2", "2", "0", "46", "0", "", "2", "", "", "2", "8.521", "0.193", "0.0004", "2.34902", "14.421", "0.237", "0.0003", "2.32744", "0.0", "", "", "", "00020005", "", "A", "80", "XL", "94", "16", "70", "76.3", "87.9", "98.2", "", "", "", "", "96.3"]} -{"pcdb_id": 18960, "brand_name": "Viessmann", "model_name": "VITODENS 111-W", "model_qualifier": "B1LF-32", "winter_efficiency_pct": 89.8, "summer_efficiency_pct": 85.2, "comparative_hot_water_efficiency_pct": 61.6, "output_kw_max": 29.3, "final_year_of_manufacture": null, "raw": ["018960", "020094", "0", "2022/Jan/24 12:26", "Viessmann Ltd", "Viessmann", "VITODENS 111-W", "B1LF-32", "", "2021", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "29.3", "29.3", "A", "", "89.8", "85.2", "", "61.6", "", "2", "0", "2", "106", "1", "2", "21", "3.8", "2", "2", "0", "46", "0", "", "2", "", "", "2", "8.744", "0.184", "0.0006", "2.56778", "15.024", "0.221", "0.0004", "2.08007", "0.0", "", "", "", "00020005", "", "A", "80", "XL", "94", "16", "70", "76.3", "90.1", "98.3", "", "", "", "", "96.7"]} -{"pcdb_id": 18961, "brand_name": "SIME", "model_name": "EDEA", "model_qualifier": "25T", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 24.5, "final_year_of_manufacture": null, "raw": ["018961", "020132", "0", "2022/Mar/05 12:54", "FONDERIE SIME SPA", "SIME", "EDEA", "25T", "41-283-64", "2021", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "11.2", "24.5", "A", "", "88.5", "79.5", "", "58.1", "", "2", "", "", "102", "1", "2", "32", "4", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "93", "17", "80", "105.0", "88.4", "98.0", "", "", "", "", "96.2"]} -{"pcdb_id": 18962, "brand_name": "SIME", "model_name": "EDEA", "model_qualifier": "35T", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 34.1, "final_year_of_manufacture": null, "raw": ["018962", "020132", "0", "2022/Mar/05 13:05", "FONDERIE SIME SPA", "SIME", "EDEA", "35T", "41-283-65", "2021", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "16.2", "34.1", "A", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "63", "6", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "93", "15", "105", "115.0", "88.3", "97.8", "", "", "", "", "96.0"]} -{"pcdb_id": 18963, "brand_name": "SIME", "model_name": "EDEA", "model_qualifier": "30", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 73.7, "comparative_hot_water_efficiency_pct": 73.5, "output_kw_max": 24.5, "final_year_of_manufacture": null, "raw": ["018963", "020132", "0", "2022/Mar/05 13:56", "FONDERIE SIME SPA", "SIME", "EDEA", "30", "47-283-91", "2021", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "9.4", "24.5", "A", "", "88.5", "73.7", "", "73.5", "", "2", "", "", "104", "1", "2", "43", "4", "0", "", "", "", "0", "", "", "", "", "2", "7.163", "0.147", "0.0", "1.05422", "14.298", "0.17", "0.0021", "0.0", "-0.00002", "0", "", "", "0025", "", "A", "86", "XL", "93", "17", "86", "105.0", "88.3", "97.8", "", "", "", "", "96.0"]} -{"pcdb_id": 18964, "brand_name": "SIME", "model_name": "EDEA", "model_qualifier": "40", "winter_efficiency_pct": 90.1, "summer_efficiency_pct": 86.6, "comparative_hot_water_efficiency_pct": 70.4, "output_kw_max": 34.1, "final_year_of_manufacture": null, "raw": ["018964", "020132", "0", "2022/Mar/05 13:20", "FONDERIE SIME SPA", "SIME", "EDEA", "40", "47-283-92", "2021", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "13.6", "34.1", "A", "", "90.1", "86.6", "", "70.4", "", "2", "", "", "104", "1", "2", "63", "6", "0", "", "", "", "0", "", "", "", "", "2", "7.476", "0.168", "0.004", "1.45839", "13.54", "0.18", "0.0035", "1.17283", "0.0", "0", "", "", "0025", "", "A", "86", "XXL", "93", "15", "105", "115.0", "98.0", "108.5", "", "", "", "", "106.5"]} -{"pcdb_id": 18965, "brand_name": "Viessmann", "model_name": "VITODENS 100-W Heat Only", "model_qualifier": "B1GA-11", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 11.5, "final_year_of_manufacture": null, "raw": ["018965", "020094", "0", "2022/Apr/20 17:58", "Viessmann Ltd", "Viessmann", "VITODENS 100-W Heat Only", "B1GA-11", "41-819-52", "2021", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "11.5", "11.5", "A", "", "88.5", "79.5", "", "58.1", "", "2", "", "", "102", "1", "2", "17", "3.9", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "00020005", "", "", "", "", "92", "20", "77", "54.7", "88.2", "98.0", "", "", "", "", "96.1"]} -{"pcdb_id": 18966, "brand_name": "Viessmann", "model_name": "VITODENS 100-W Heat Only", "model_qualifier": "B1GA-16", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 15.06, "final_year_of_manufacture": null, "raw": ["018966", "020094", "0", "2022/Apr/21 12:49", "Viessmann Ltd", "Viessmann", "VITODENS 100-W Heat Only", "B1GA-16", "41-819-53", "2021", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "15.06", "15.06", "A", "", "88.3", "79.3", "", "57.9", "", "2", "", "", "102", "1", "2", "17", "3.9", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "00020005", "", "", "", "", "92", "19", "75", "54.7", "88.1", "97.5", "", "", "", "", "95.7"]} -{"pcdb_id": 18967, "brand_name": "Viessmann", "model_name": "VITODENS 100-W Heat Only", "model_qualifier": "B1GA-19", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 17.3, "final_year_of_manufacture": null, "raw": ["018967", "020094", "0", "2022/Apr/21 13:14", "Viessmann Ltd", "Viessmann", "VITODENS 100-W Heat Only", "B1GA-19", "41-819-54", "2021", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "17.3", "17.3", "A", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "15", "3.9", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "00020005", "", "", "", "", "92", "18", "71", "54.7", "88.0", "97.8", "", "", "", "", "95.9"]} -{"pcdb_id": 18968, "brand_name": "Viessmann", "model_name": "VITODENS 100-W Heat Only", "model_qualifier": "B1GA-25", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 23.06, "final_year_of_manufacture": null, "raw": ["018968", "020094", "0", "2022/Apr/21 13:23", "Viessmann Ltd", "Viessmann", "VITODENS 100-W Heat Only", "B1GA-25", "41-819-55", "2021", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "23.06", "23.06", "A", "", "88.5", "79.5", "", "58.0", "", "2", "", "", "102", "1", "2", "15", "3.9", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "00020005", "", "", "", "", "92", "21", "78", "54.7", "87.9", "98.0", "", "", "", "", "96.1"]} -{"pcdb_id": 18969, "brand_name": "Viessmann", "model_name": "VITODENS 100-W Heat Only", "model_qualifier": "B1GA-32", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 29.61, "final_year_of_manufacture": null, "raw": ["018969", "020094", "0", "2022/Apr/21 13:29", "Viessmann Ltd", "Viessmann", "VITODENS 100-W Heat Only", "B1GA-32", "41-819-56", "2021", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "29.61", "29.61", "A", "", "88.5", "79.5", "", "58.1", "", "2", "", "", "102", "1", "2", "18", "3.9", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "00020005", "", "", "", "", "93", "26", "90", "54.7", "87.6", "98.2", "", "", "", "", "96.2"]} -{"pcdb_id": 18970, "brand_name": "Bosch", "model_name": "Condens 7000 WP", "model_qualifier": "GC7000WP 50 23", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 47.5, "final_year_of_manufacture": null, "raw": ["018970", "020051", "0", "2022/Jun/21 13:18", "Bosch Thermotechnology Ltd", "Bosch", "Condens 7000 WP", "GC7000WP 50 23", "7736 702 194", "2022", "current", "1", "3", "1", "1", "0", "", "", "2", "2", "2", "47.5", "47.5", "A", "", "88.5", "79.5", "", "58.0", "", "2", "", "", "102", "1", "2", "32", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "8305", "", "", "", "", "93", "10", "52", "115.0", "88.9", "97.6", "", "", "", "", "95.9"]} -{"pcdb_id": 18971, "brand_name": "Bosch", "model_name": "Condens 7000 WP", "model_qualifier": "GC7000WP 65 23", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 64.0, "final_year_of_manufacture": null, "raw": ["018971", "020051", "0", "2022/Jun/21 13:18", "Bosch Thermotechnology Ltd", "Bosch", "Condens 7000 WP", "GC7000WP 65 23", "7736 702 195", "2022", "current", "1", "3", "1", "1", "0", "", "", "2", "3", "2", "64", "64", "A", "", "88.7", "79.7", "", "58.2", "", "2", "", "", "102", "1", "2", "64", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "8305", "", "", "", "", "93", "11", "73", "115.0", "89.1", "98.1", "", "", "", "", "96.4"]} -{"pcdb_id": 18972, "brand_name": "Navien", "model_name": "LCB700", "model_qualifier": "LCB700-28LCX", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 90.0, "comparative_hot_water_efficiency_pct": 45.6, "output_kw_max": 28.4, "final_year_of_manufacture": null, "raw": ["018972", "020178", "0", "2022/Oct/21 10:08", "Navien UK", "Navien", "LCB700", "LCB700-28LCX", "28kW Outdoor", "2016", "current", "4", "1", "2", "2", "0", "", "", "2", "2", "2", "28.4", "28.4", "A", "", "89.0", "90.0", "", "45.6", "", "2", "", "", "203", "1", "2", "101", "1.8", "0", "1", "0", "30", "0", "", "0", "", "", "2", "12.007", "0.274", "0.0055", "5.71125", "18.078", "0.31", "0.0045", "5.42319", "0.00001", "", "", "", "0005", "", "B", "73", "XL", "93", "26.8", "128", "84.3", "92.4", "96.6", "", "", "", "", "95.8"]} -{"pcdb_id": 18973, "brand_name": "Sapphire", "model_name": "Sapphire 32KW", "model_qualifier": "", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 81.2, "comparative_hot_water_efficiency_pct": 59.3, "output_kw_max": 32.0, "final_year_of_manufacture": null, "raw": ["018973", "020153", "0", "2022/Jun/27 14:44", "EOGB Energy Products ltd", "Sapphire", "Sapphire 32KW", "", "", "2021", "current", "4", "1", "1", "1", "0", "", "", "2", "2", "2", "32", "32", "A", "", "89.0", "81.2", "", "59.3", "", "2", "", "", "201", "1", "2", "146", "6", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "4015", "", "", "", "", "93", "31", "188", "49.0", "91.6", "97.1", "", "", "", "", "96.0"]} -{"pcdb_id": 18974, "brand_name": "Viessmann", "model_name": "VITODENS 100-W Heat Only", "model_qualifier": "B1GA-11", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 10.3, "final_year_of_manufacture": null, "raw": ["018974", "020094", "0", "2022/Jun/24 10:00", "Viessmann Ltd", "Viessmann", "VITODENS 100-W Heat Only", "B1GA-11", "", "2022", "current", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "10.3", "10.3", "A", "", "89.0", "80.0", "", "58.4", "", "2", "0", "2", "102", "1", "2", "17", "3.9", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "00020005", "", "", "", "", "92", "20", "77", "54.7", "89.2", "96.7", "", "", "", "", "95.3"]} -{"pcdb_id": 18975, "brand_name": "Viessmann", "model_name": "VITODENS 100-W Heat Only", "model_qualifier": "B1GA-19", "winter_efficiency_pct": 89.6, "summer_efficiency_pct": 80.6, "comparative_hot_water_efficiency_pct": 58.9, "output_kw_max": 17.2, "final_year_of_manufacture": null, "raw": ["018975", "020094", "0", "2022/Jun/24 09:54", "Viessmann Ltd", "Viessmann", "VITODENS 100-W Heat Only", "B1GA-19", "", "2022", "current", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "17.2", "17.2", "A", "", "89.6", "80.6", "", "58.9", "", "2", "0", "2", "102", "1", "2", "15", "3.9", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "00020005", "", "", "", "", "92", "18", "71", "54.7", "90.1", "97.9", "", "", "", "", "96.4"]} -{"pcdb_id": 18976, "brand_name": "Viessmann", "model_name": "VITODENS 100-W Heat Only", "model_qualifier": "B1GA-25", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 80.4, "comparative_hot_water_efficiency_pct": 58.8, "output_kw_max": 22.8, "final_year_of_manufacture": null, "raw": ["018976", "020094", "0", "2022/Jun/24 09:41", "Viessmann Ltd", "Viessmann", "VITODENS 100-W Heat Only", "B1GA-25", "", "2022", "current", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "22.8", "22.8", "A", "", "89.4", "80.4", "", "58.8", "", "2", "0", "2", "102", "1", "2", "15", "3.9", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "00020005", "", "", "", "", "92", "21", "78", "54.7", "89.7", "97.6", "", "", "", "", "96.1"]} -{"pcdb_id": 18977, "brand_name": "Viessmann", "model_name": "VITODENS 100-W Heat Only", "model_qualifier": "B1GA-32", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 80.4, "comparative_hot_water_efficiency_pct": 58.7, "output_kw_max": 29.0, "final_year_of_manufacture": null, "raw": ["018977", "020094", "0", "2022/Jun/24 09:32", "Viessmann Ltd", "Viessmann", "VITODENS 100-W Heat Only", "B1GA-32", "", "2022", "current", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "29", "29", "A", "", "89.4", "80.4", "", "58.7", "", "2", "0", "2", "102", "1", "2", "18", "3.9", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "00020005", "", "", "", "", "93", "26", "90", "54.7", "89.5", "97.6", "", "", "", "", "96.1"]} -{"pcdb_id": 18978, "brand_name": "Viessmann", "model_name": "VITODENS 100-W Heat Only", "model_qualifier": "B1GA-16", "winter_efficiency_pct": 89.5, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 58.8, "output_kw_max": 14.8, "final_year_of_manufacture": null, "raw": ["018978", "020094", "0", "2022/Jun/24 09:23", "Viessmann Ltd", "Viessmann", "VITODENS 100-W Heat Only", "B1GA-16", "", "2022", "current", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "14.8", "14.8", "A", "", "89.5", "80.5", "", "58.8", "", "2", "0", "2", "102", "1", "2", "17", "3.9", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "00020005", "", "", "", "", "92", "19", "75", "54.7", "90.0", "97.6", "", "", "", "", "96.2"]} -{"pcdb_id": 18979, "brand_name": "Viessmann", "model_name": "VITODENS 050-W", "model_qualifier": "B0HA-19", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 17.3, "final_year_of_manufacture": null, "raw": ["018979", "020094", "0", "2022/Jun/24 17:25", "Viessmann Ltd", "Viessmann", "VITODENS 050-W", "B0HA-19", "", "2021", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "17.3", "17.3", "A", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "15", "3.9", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "00020005", "", "", "", "", "92", "18", "71", "54.7", "88.0", "97.8", "", "", "", "", "95.9"]} -{"pcdb_id": 18980, "brand_name": "Viessmann", "model_name": "VITODENS 050-W", "model_qualifier": "B0HA-19", "winter_efficiency_pct": 85.1, "summer_efficiency_pct": 76.1, "comparative_hot_water_efficiency_pct": 55.6, "output_kw_max": 17.2, "final_year_of_manufacture": null, "raw": ["018980", "020094", "0", "2022/Jun/24 17:30", "Viessmann Ltd", "Viessmann", "VITODENS 050-W", "B0HA-19", "", "2022", "current", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "17.2", "17.2", "A", "", "85.1", "76.1", "", "55.6", "", "2", "0", "2", "102", "1", "2", "15", "3.9", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "00020005", "", "", "", "", "92", "18", "71", "54.7", "80.1", "97.2", "", "", "", "", "94.0"]} -{"pcdb_id": 18981, "brand_name": "Viessmann", "model_name": "VITODENS 050-W", "model_qualifier": "B0HA-25", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 80.4, "comparative_hot_water_efficiency_pct": 58.8, "output_kw_max": 22.8, "final_year_of_manufacture": null, "raw": ["018981", "020094", "0", "2022/Jun/24 17:30", "Viessmann Ltd", "Viessmann", "VITODENS 050-W", "B0HA-25", "", "2022", "current", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "22.8", "22.8", "A", "", "89.4", "80.4", "", "58.8", "", "2", "0", "2", "102", "1", "2", "15", "3.9", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "00020005", "", "", "", "", "92", "21", "78", "54.7", "89.7", "97.6", "", "", "", "", "96.1"]} -{"pcdb_id": 18982, "brand_name": "Navien", "model_name": "LCB700", "model_qualifier": "LCB700-28LSX", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 81.2, "comparative_hot_water_efficiency_pct": 59.3, "output_kw_max": 28.4, "final_year_of_manufacture": null, "raw": ["018982", "020178", "0", "2022/Oct/21 10:06", "Navien UK", "Navien", "LCB700", "LCB700-28LSX", "LCB700-28kW", "2016", "current", "4", "1", "2", "1", "0", "", "", "2", "2", "2", "28.4", "28.4", "A", "", "89.0", "81.2", "", "59.3", "", "2", "", "", "201", "1", "2", "101", "1.8", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "93", "26.8", "128", "84.3", "92.4", "96.6", "", "", "", "", "95.8"]} -{"pcdb_id": 18983, "brand_name": "Navien", "model_name": "LCB700", "model_qualifier": "LCB700-28RSX", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 81.2, "comparative_hot_water_efficiency_pct": 59.3, "output_kw_max": 28.4, "final_year_of_manufacture": null, "raw": ["018983", "020178", "0", "2022/Oct/21 10:05", "Navien UK", "Navien", "LCB700", "LCB700-28RSX", "", "2016", "current", "4", "1", "2", "1", "0", "", "", "2", "2", "2", "28.4", "28.4", "A", "", "89.0", "81.2", "", "59.3", "", "2", "", "", "201", "1", "2", "101", "1.8", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "93", "26.8", "128", "84.3", "92.4", "96.6", "", "", "", "", "95.8"]} -{"pcdb_id": 18984, "brand_name": "Navien", "model_name": "LCB700", "model_qualifier": "LCB700-36LSX", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 81.3, "comparative_hot_water_efficiency_pct": 59.4, "output_kw_max": 36.3, "final_year_of_manufacture": null, "raw": ["018984", "020178", "0", "2022/Oct/21 10:05", "Navien UK", "Navien", "LCB700", "LCB700-36LSX", "", "2016", "current", "4", "1", "2", "1", "0", "", "", "2", "2", "2", "36.3", "36.3", "A", "", "89.1", "81.3", "", "59.4", "", "2", "", "", "201", "1", "2", "124", "1.7", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "93", "32.8", "153", "73.0", "92.2", "97.1", "", "", "", "", "96.1"]} -{"pcdb_id": 18985, "brand_name": "Navien", "model_name": "LCB700", "model_qualifier": "LCB700-36RSX", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 81.3, "comparative_hot_water_efficiency_pct": 59.4, "output_kw_max": 36.5, "final_year_of_manufacture": null, "raw": ["018985", "020178", "0", "2022/Oct/21 10:04", "Navien UK", "Navien", "LCB700", "LCB700-36RSX", "", "2016", "current", "4", "1", "2", "1", "0", "", "", "2", "2", "2", "36.5", "36.5", "A", "", "89.1", "81.3", "", "59.4", "", "2", "", "", "201", "1", "2", "124", "1.7", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "93", "32.8", "153", "73.0", "92.2", "97.1", "", "", "", "", "96.1"]} -{"pcdb_id": 18986, "brand_name": "Navien", "model_name": "LCB700", "model_qualifier": "LCB700-36LCX", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 91.5, "comparative_hot_water_efficiency_pct": 44.1, "output_kw_max": 36.0, "final_year_of_manufacture": null, "raw": ["018986", "020178", "0", "2022/Oct/21 10:04", "Navien", "Navien", "LCB700", "LCB700-36LCX", "", "2016", "current", "4", "1", "2", "2", "0", "", "", "2", "2", "2", "36", "36", "A", "", "89.1", "91.5", "", "44.1", "", "2", "", "", "203", "1", "2", "124", "1.7", "0", "", "0", "30", "0", "", "0", "", "", "2", "12.433", "0.3", "0.0015", "6.13765", "18.129", "0.315", "0.0015", "6.04449", "0.0", "", "", "", "0005", "", "B", "73", "XL", "93", "32.8", "153", "73.0", "92.2", "97.1", "", "", "", "", "96.1"]} -{"pcdb_id": 18987, "brand_name": "Navien", "model_name": "LCB700", "model_qualifier": "LCB700-21RSX", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 81.3, "comparative_hot_water_efficiency_pct": 59.4, "output_kw_max": 21.2, "final_year_of_manufacture": null, "raw": ["018987", "020178", "0", "2022/Oct/21 10:04", "Navien UK", "Navien", "LCB700", "LCB700-21RSX", "", "2016", "current", "4", "1", "2", "1", "0", "", "", "2", "2", "2", "21.2", "21.2", "A", "", "89.1", "81.3", "", "59.4", "", "2", "", "", "201", "1", "2", "94", "1.6", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "93", "28", "125", "73.0", "92.0", "97.0", "", "", "", "", "96.0"]} -{"pcdb_id": 18988, "brand_name": "Navien", "model_name": "LCB700", "model_qualifier": "LCB700-21LSX", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 81.3, "comparative_hot_water_efficiency_pct": 59.4, "output_kw_max": 21.2, "final_year_of_manufacture": null, "raw": ["018988", "020178", "0", "2022/Oct/21 10:03", "Navien UK", "Navien", "LCB700", "LCB700-21LSX", "", "2016", "current", "4", "1", "2", "1", "0", "", "", "2", "2", "2", "21.2", "21.2", "A", "", "89.1", "81.3", "", "59.4", "", "2", "", "", "201", "1", "2", "94", "1.6", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "93", "28", "125", "73.1", "92.0", "97.0", "", "", "", "", "96.0"]} -{"pcdb_id": 18989, "brand_name": "Navien", "model_name": "LCB700", "model_qualifier": "LCB700-21LCX", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 91.5, "comparative_hot_water_efficiency_pct": 46.6, "output_kw_max": 21.2, "final_year_of_manufacture": null, "raw": ["018989", "020178", "0", "2022/Oct/21 10:12", "Navien UK", "Navien", "LCB700", "LCB700-21LCX", "", "2016", "current", "4", "1", "2", "2", "0", "", "", "2", "2", "2", "21.2", "21.2", "A", "", "89.1", "91.5", "", "46.6", "", "2", "", "", "203", "1", "2", "94", "1.6", "0", "", "0", "30", "0", "", "0", "", "", "2", "11.745", "0.284", "0.0", "5.47517", "17.691", "0.3", "0.0035", "5.39485", "-0.00004", "", "", "", "0005", "", "A", "74", "XL", "93", "28", "125", "73.0", "92.0", "97.0", "", "", "", "", "96.0"]} -{"pcdb_id": 18990, "brand_name": "Navien", "model_name": "LCB700", "model_qualifier": "LCB700-36LC", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 91.5, "comparative_hot_water_efficiency_pct": 44.1, "output_kw_max": 36.3, "final_year_of_manufacture": null, "raw": ["018990", "020178", "0", "2022/Oct/21 10:11", "Navien UK", "Navien", "LCB700", "LCB700-36LC", "", "2016", "current", "4", "1", "1", "2", "0", "", "", "2", "2", "2", "36.3", "36.3", "A", "", "89.1", "91.5", "", "44.1", "", "2", "", "", "203", "1", "2", "124", "1.7", "0", "", "0", "30", "0", "", "0", "", "", "2", "12.433", "0.3", "0.0015", "6.12139", "18.129", "0.315", "0.0015", "6.04449", "0.0", "", "", "", "0005", "", "B", "73", "XL", "93", "32.8", "153", "73.1", "91.8", "97.1", "", "", "", "", "96.1"]} -{"pcdb_id": 18991, "brand_name": "Navien", "model_name": "LCB700", "model_qualifier": "LCB700-36LS", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 81.3, "comparative_hot_water_efficiency_pct": 59.4, "output_kw_max": 36.3, "final_year_of_manufacture": null, "raw": ["018991", "020178", "0", "2022/Oct/21 10:11", "Navien UK", "Navien", "LCB700", "LCB700-36LS", "", "2016", "current", "4", "1", "1", "1", "0", "", "", "2", "2", "2", "36.3", "36.3", "A", "", "89.1", "81.3", "", "59.4", "", "2", "", "", "201", "1", "2", "124", "1.7", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "93", "32.8", "153", "73.1", "91.8", "97.1", "", "", "", "", "96.1"]} -{"pcdb_id": 18992, "brand_name": "Navien", "model_name": "LCB700", "model_qualifier": "LCB700-36RS", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 81.3, "comparative_hot_water_efficiency_pct": 59.4, "output_kw_max": 36.3, "final_year_of_manufacture": null, "raw": ["018992", "020178", "0", "2022/Oct/21 10:11", "Navien UK", "Navien", "LCB700", "LCB700-36RS", "", "2016", "current", "4", "1", "1", "1", "0", "", "", "2", "2", "2", "36.3", "36.3", "A", "", "89.1", "81.3", "", "59.4", "", "2", "", "", "201", "1", "2", "124", "1.7", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "93", "32.8", "153", "73.1", "91.8", "97.1", "", "", "", "", "96.1"]} -{"pcdb_id": 18993, "brand_name": "Navien", "model_name": "LCB700", "model_qualifier": "LCB700-28LC", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 90.0, "comparative_hot_water_efficiency_pct": 45.6, "output_kw_max": 28.4, "final_year_of_manufacture": null, "raw": ["018993", "020178", "0", "2022/Oct/21 10:10", "Navien UK", "Navien", "LCB700", "LCB700-28LC", "", "2016", "current", "4", "1", "1", "2", "0", "", "", "2", "2", "2", "28.4", "28.4", "A", "", "89.0", "90.0", "", "45.6", "", "2", "", "", "203", "1", "2", "101", "1.8", "0", "", "0", "30", "0", "", "0", "", "", "2", "12.007", "0.274", "0.0055", "5.71125", "18.078", "0.31", "0.0045", "5.42319", "0.00001", "", "", "", "0005", "", "B", "73", "XL", "93", "27", "128", "84.0", "92.4", "96.6", "", "", "", "", "95.8"]} -{"pcdb_id": 18994, "brand_name": "Navien", "model_name": "LCB700", "model_qualifier": "LCB700-28LS", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 81.2, "comparative_hot_water_efficiency_pct": 59.3, "output_kw_max": 28.4, "final_year_of_manufacture": null, "raw": ["018994", "020178", "0", "2022/Oct/21 10:10", "Navien UK", "Navien", "LCB700", "LCB700-28LS", "", "2016", "current", "4", "1", "1", "1", "0", "", "", "2", "2", "2", "28.4", "28.4", "A", "", "89.0", "81.2", "", "59.3", "", "2", "", "", "201", "1", "2", "101", "1.8", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "93", "27", "128", "84.0", "92.4", "96.6", "", "", "", "", "95.8"]} -{"pcdb_id": 18995, "brand_name": "Navien", "model_name": "LCB700", "model_qualifier": "LCB700-28RS", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 81.2, "comparative_hot_water_efficiency_pct": 59.3, "output_kw_max": 28.4, "final_year_of_manufacture": null, "raw": ["018995", "020178", "0", "2022/Oct/21 10:09", "Navien UK", "Navien", "LCB700", "LCB700-28RS", "", "2016", "current", "4", "1", "1", "1", "0", "", "", "2", "2", "2", "28.4", "28.4", "A", "", "89.0", "81.2", "", "59.3", "", "2", "", "", "201", "1", "2", "101", "1.8", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "93", "27", "128", "84.3", "92.4", "96.6", "", "", "", "", "95.8"]} -{"pcdb_id": 18996, "brand_name": "Navien", "model_name": "LCB700", "model_qualifier": "LCB700-21RS", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 81.3, "comparative_hot_water_efficiency_pct": 59.4, "output_kw_max": 21.2, "final_year_of_manufacture": null, "raw": ["018996", "020178", "0", "2022/Oct/21 10:09", "Navien UK", "Navien", "LCB700", "LCB700-21RS", "", "2016", "current", "4", "1", "1", "1", "0", "", "", "2", "2", "2", "21.2", "21.2", "A", "", "89.1", "81.3", "", "59.4", "", "2", "", "", "201", "1", "2", "94", "1.6", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "93", "28", "125", "73.0", "92.0", "97.0", "", "", "", "", "96.0"]} -{"pcdb_id": 18997, "brand_name": "Navien", "model_name": "LCB700", "model_qualifier": "LCB700-21LS", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 81.3, "comparative_hot_water_efficiency_pct": 59.4, "output_kw_max": 21.62, "final_year_of_manufacture": null, "raw": ["018997", "020178", "0", "2022/Oct/21 10:01", "Navien UK", "Navien", "LCB700", "LCB700-21LS", "", "2016", "current", "4", "1", "1", "1", "0", "", "", "2", "2", "2", "21.62", "21.62", "A", "", "89.1", "81.3", "", "59.4", "", "2", "", "", "201", "1", "2", "94", "1.6", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "B", "74", "", "93", "28", "125", "73.0", "92.0", "97.0", "", "", "", "", "96.0"]} -{"pcdb_id": 18998, "brand_name": "Navien", "model_name": "LCB700", "model_qualifier": "LCB700-21LC", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 91.5, "comparative_hot_water_efficiency_pct": 46.6, "output_kw_max": 21.2, "final_year_of_manufacture": null, "raw": ["018998", "020178", "0", "2022/Oct/21 10:00", "Navien UK", "Navien", "LCB700", "LCB700-21LC", "", "2016", "current", "4", "1", "1", "2", "0", "", "", "2", "2", "2", "21.2", "21.2", "A", "", "89.1", "91.5", "", "46.6", "", "2", "", "", "203", "1", "2", "94", "1.6", "0", "", "0", "30", "0", "", "0", "", "", "2", "11.745", "0.284", "0.0", "5.47517", "17.691", "0.3", "0.0035", "5.39485", "-0.00004", "", "", "", "0005", "", "B", "74", "XL", "93", "28", "125", "73.0", "92.0", "97.0", "", "", "", "", "96.0"]} -{"pcdb_id": 18999, "brand_name": "Viessmann", "model_name": "VITODENS 050-W", "model_qualifier": "B0KA-25", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 86.9, "comparative_hot_water_efficiency_pct": 70.7, "output_kw_max": 17.3, "final_year_of_manufacture": null, "raw": ["018999", "020094", "0", "2022/Jul/04 09:57", "Viessmann Ltd", "Viessmann", "VITODENS 050-W", "B0KA-25", "", "2021", "current", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "17.3", "17.3", "A", "", "88.4", "86.9", "", "70.7", "", "2", "", "", "104", "1", "2", "15", "3.9", "0", "", "", "", "0", "", "", "", "", "2", "7.451", "0.17", "0.0028", "1.30719", "13.473", "0.194", "0.0014", "1.18349", "0.00001", "0", "", "", "00020005", "", "A", "82", "XL", "92", "18", "71", "54.7", "88.0", "97.8", "", "", "", "", "95.9"]} -{"pcdb_id": 19000, "brand_name": "Viessmann", "model_name": "VITODENS 050-W", "model_qualifier": "B0KA-30", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 86.6, "comparative_hot_water_efficiency_pct": 71.7, "output_kw_max": 23.0, "final_year_of_manufacture": null, "raw": ["019000", "020094", "0", "2022/Jul/04 10:15", "Viessmann Ltd", "Viessmann", "VITODENS 050-W", "B0KA-30", "", "2021", "current", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "23", "23", "A", "", "88.5", "86.6", "", "71.7", "", "2", "", "", "104", "1", "2", "15", "3.9", "0", "", "", "", "0", "", "", "", "", "2", "7.35", "0.173", "0.0025", "1.2094", "13.393", "0.194", "0.0008", "1.06", "0.00002", "0", "", "", "00020005", "", "A", "82", "XL", "92", "21", "78", "54.7", "87.9", "98.0", "", "", "", "", "96.1"]} -{"pcdb_id": 19001, "brand_name": "Viessmann", "model_name": "VITODENS 050-W", "model_qualifier": "B0KA-30-M", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 86.6, "comparative_hot_water_efficiency_pct": 71.7, "output_kw_max": 23.6, "final_year_of_manufacture": null, "raw": ["019001", "020094", "0", "2022/Jul/04 10:31", "Viessmann Ltd", "Viessmann", "VITODENS 050-W", "B0KA-30-M", "", "2021", "current", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "23.6", "23.6", "A", "", "88.5", "86.6", "", "71.7", "", "2", "", "", "104", "1", "2", "13", "3.9", "0", "", "", "", "0", "", "", "", "", "2", "7.35", "0.173", "0.0025", "1.2094", "13.393", "0.194", "0.0008", "1.06", "0.00002", "0", "", "", "00020005", "", "A", "82", "XL", "92", "22", "79", "54.7", "87.9", "98.0", "", "", "", "", "96.1"]} -{"pcdb_id": 19002, "brand_name": "Viessmann", "model_name": "VITODENS 050-W", "model_qualifier": "B0KA-30", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 88.9, "comparative_hot_water_efficiency_pct": 70.1, "output_kw_max": 22.8, "final_year_of_manufacture": null, "raw": ["019002", "020094", "0", "2022/Jul/26 12:00", "Viessmann Ltd", "Viessmann", "VITODENS 050-W", "B0KA-30", "", "2022", "current", "2", "2", "1", "2", "0", "", "", "2", "3", "2", "22.8", "22.8", "A", "", "89.4", "88.9", "", "70.1", "", "2", "0", "2", "104", "1", "2", "15", "3.9", "0", "", "", "", "0", "", "", "", "", "2", "7.676", "0.18", "0.003", "1.51559", "13.701", "0.202", "0.0018", "1.39581", "0.00001", "0", "", "", "00020005", "", "A", "82", "XL", "92", "21", "78", "54.7", "89.7", "97.6", "", "", "", "", "96.1"]} -{"pcdb_id": 19003, "brand_name": "Ideal Heating", "model_name": "LOGIC CODE COMBI2", "model_qualifier": "38", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 98.9, "comparative_hot_water_efficiency_pct": 83.1, "output_kw_max": 24.2, "final_year_of_manufacture": null, "raw": ["019003", "020099", "0", "2022/Jul/07 14:14", "Ideal Boilers", "Ideal Heating", "LOGIC CODE COMBI2", "38", "47-387-20", "2022", "current", "1", "2", "1", "2", "1", "", "", "2", "2", "2", "24.2", "24.2", "A", "", "89.0", "98.9", "", "83.1", "", "2", "", "", "104", "1", "2", "79", "2.4", "0", "", "", "", "0", "", "", "", "", "2", "6.335", "0.074", "0.0028", "0.27965", "11.439", "0.096", "0.0035", "0.95324", "-0.00001", "0", "", "", "0035", "", "A", "92", "L", "97", "55", "180", "5.0", "90.0", "98.6", "", "", "", "", "96.9"]} -{"pcdb_id": 19004, "brand_name": "Viessmann", "model_name": "VITODENS 050-W", "model_qualifier": "B0KA-25", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 90.2, "comparative_hot_water_efficiency_pct": 70.2, "output_kw_max": 22.8, "final_year_of_manufacture": null, "raw": ["019004", "020094", "0", "2022/Jul/26 11:58", "Viessmann Ltd", "Viessmann", "VITODENS 050-W", "B0KA-25", "", "2022", "current", "2", "2", "1", "2", "0", "", "", "2", "3", "2", "22.8", "22.8", "A", "", "89.4", "90.2", "", "70.2", "", "2", "0", "2", "104", "1", "2", "15", "3.9", "0", "", "", "", "0", "", "", "", "", "2", "7.673", "0.178", "0.0054", "1.49868", "13.593", "0.198", "0.0018", "1.48907", "0.00004", "0", "", "", "00020005", "", "A", "82", "XL", "92", "18", "71", "54.7", "89.7", "97.6", "", "", "", "", "96.1"]} -{"pcdb_id": 19005, "brand_name": "Viessmann", "model_name": "VITODENS 050-W", "model_qualifier": "B0HA-25", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 23.0, "final_year_of_manufacture": null, "raw": ["019005", "020094", "0", "2022/Jun/24 17:25", "Viessmann Ltd", "Viessmann", "VITODENS 050-W", "B0HA-25", "", "2021", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "23", "23", "A", "", "88.5", "79.5", "", "58.0", "", "2", "", "", "102", "1", "2", "15", "3.9", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "00020005", "", "", "", "", "92", "21", "78", "54.7", "87.9", "98.0", "", "", "", "", "96.1"]} -{"pcdb_id": 19006, "brand_name": "Ideal Heating", "model_name": "LOGIC COMBI2", "model_qualifier": "C24", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 88.2, "comparative_hot_water_efficiency_pct": 70.0, "output_kw_max": 24.2, "final_year_of_manufacture": null, "raw": ["019006", "020099", "0", "2024/Dec/10 16:50", "Ideal Boilers", "Ideal Heating", "LOGIC COMBI2", "C24", "47-349-93", "2022", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "A", "", "89.0", "88.2", "", "70.0", "", "2", "", "", "104", "1", "2", "46", "2", "0", "", "", "", "0", "", "", "", "", "2", "7.518", "0.131", "0.0115", "1.37564", "13.292", "0.157", "0.0045", "1.30006", "0.00007", "0", "", "", "0035", "", "A", "81", "L", "94", "13", "67", "50.0", "90.0", "98.6", "", "", "", "", "96.9"]} -{"pcdb_id": 19007, "brand_name": "Ideal Heating", "model_name": "LOGIC COMBI2", "model_qualifier": "C30", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 88.2, "comparative_hot_water_efficiency_pct": 70.9, "output_kw_max": 24.2, "final_year_of_manufacture": null, "raw": ["019007", "020099", "0", "2024/Dec/10 16:51", "Ideal Boilers", "Ideal Heating", "LOGIC COMBI2", "C30", "47-349-94", "2022", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "A", "", "89.0", "88.2", "", "70.9", "", "2", "", "", "104", "1", "2", "27", "3", "0", "", "", "", "0", "", "", "", "", "2", "7.425", "0.137", "0.0045", "1.3264", "13.175", "0.157", "0.003", "1.25175", "0.00002", "0", "", "", "0035", "", "A", "81", "L", "94", "10", "55", "50.0", "90.0", "98.6", "", "", "", "", "96.9"]} -{"pcdb_id": 19008, "brand_name": "Ideal Heating", "model_name": "LOGIC COMBI2", "model_qualifier": "C35", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 86.6, "comparative_hot_water_efficiency_pct": 69.3, "output_kw_max": 24.2, "final_year_of_manufacture": null, "raw": ["019008", "020099", "0", "2024/Dec/10 16:52", "Ideal Boilers", "Ideal Heating", "LOGIC COMBI2", "C35", "47-349-95", "2022", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "A", "", "89.0", "86.6", "", "69.3", "", "2", "", "", "104", "1", "2", "26", "2", "0", "", "", "", "0", "", "", "", "", "2", "7.6", "0.136", "0.0135", "1.44344", "13.634", "0.158", "0.006", "1.23652", "0.00008", "0", "", "", "0035", "", "A", "79", "L", "94", "12", "53", "50.0", "90.0", "98.6", "", "", "", "", "96.9"]} -{"pcdb_id": 19009, "brand_name": "Ideal Heating", "model_name": "LOGIC HEAT2", "model_qualifier": "H12", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 12.0, "final_year_of_manufacture": null, "raw": ["019009", "020099", "0", "2024/Dec/10 17:06", "Ideal Boilers", "Ideal Heating", "LOGIC HEAT2", "H12", "41-860-10", "2022", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "12", "12", "A", "", "88.8", "79.8", "", "58.3", "", "2", "", "", "102", "1", "2", "16", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "93", "11", "45", "50.0", "90.0", "97.9", "", "", "", "", "96.4"]} -{"pcdb_id": 19010, "brand_name": "Ideal Heating", "model_name": "LOGIC HEAT2", "model_qualifier": "H15", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 15.0, "final_year_of_manufacture": null, "raw": ["019010", "020099", "0", "2024/Dec/10 17:06", "Ideal Boilers", "Ideal Heating", "LOGIC HEAT2", "H15", "41-860-11", "2022", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "15", "15", "A", "", "88.7", "79.7", "", "58.2", "", "2", "", "", "102", "1", "2", "22", "3", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "93", "11", "55", "50.0", "90.0", "97.8", "", "", "", "", "96.4"]} -{"pcdb_id": 19011, "brand_name": "Ideal Heating", "model_name": "LOGIC HEAT2", "model_qualifier": "H18", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 18.0, "final_year_of_manufacture": null, "raw": ["019011", "020099", "0", "2024/Dec/10 17:07", "Ideal Boilers", "Ideal Heating", "LOGIC HEAT2", "H18", "41-860-12", "2022", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18", "18", "A", "", "89.0", "80.0", "", "58.4", "", "2", "", "", "102", "1", "2", "25", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "93", "4", "35", "50.0", "89.8", "98.5", "", "", "", "", "96.8"]} -{"pcdb_id": 19012, "brand_name": "Ideal Heating", "model_name": "LOGIC HEAT2", "model_qualifier": "H24", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 24.2, "final_year_of_manufacture": null, "raw": ["019012", "020099", "0", "2024/Dec/10 17:07", "Ideal Boilers", "Ideal Heating", "LOGIC HEAT2", "H24", "41-860-13", "2022", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24.2", "24.2", "A", "", "89.0", "80.0", "", "58.5", "", "2", "", "", "102", "1", "2", "46", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "94", "13", "67", "50.0", "90.0", "98.6", "", "", "", "", "96.9"]} -{"pcdb_id": 19013, "brand_name": "Ideal Heating", "model_name": "LOGIC HEAT2", "model_qualifier": "H30", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 30.4, "final_year_of_manufacture": null, "raw": ["019013", "020099", "0", "2024/Dec/10 17:08", "Ideal Boilers", "Ideal Heating", "LOGIC HEAT2", "H30", "41-860-14", "2022", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "30.4", "30.4", "A", "", "88.9", "79.9", "", "58.3", "", "2", "", "", "102", "1", "2", "50", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "93", "12", "67", "50.0", "89.8", "98.2", "", "", "", "", "96.6"]} -{"pcdb_id": 19014, "brand_name": "Ideal Heating", "model_name": "LOGIC SYSTEM2", "model_qualifier": "S15", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 15.1, "final_year_of_manufacture": null, "raw": ["019014", "020099", "0", "2024/Dec/11 10:25", "Ideal Boilers", "Ideal Heating", "LOGIC SYSTEM2", "S15", "41-796-85", "2022", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "15.1", "15.1", "A", "", "88.7", "79.7", "", "58.2", "", "2", "", "", "102", "1", "2", "42", "3", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "93", "17", "79", "50.0", "90.0", "97.8", "", "", "", "", "96.4"]} -{"pcdb_id": 19015, "brand_name": "Ideal Heating", "model_name": "LOGIC SYSTEM2", "model_qualifier": "S18", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 18.1, "final_year_of_manufacture": null, "raw": ["019015", "020099", "0", "2024/Dec/11 10:26", "Ideal Boilers", "Ideal Heating", "LOGIC SYSTEM2", "S18", "41-796-86", "2022", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18.1", "18.1", "A", "", "89.0", "80.0", "", "58.4", "", "2", "", "", "102", "1", "2", "25", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "93", "3", "33", "50.0", "89.8", "98.5", "", "", "", "", "96.8"]} -{"pcdb_id": 19016, "brand_name": "Ideal Heating", "model_name": "LOGIC SYSTEM2", "model_qualifier": "S24", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 24.3, "final_year_of_manufacture": null, "raw": ["019016", "020099", "0", "2024/Dec/11 10:54", "Ideal Boilers", "Ideal Heating", "LOGIC SYSTEM2", "S24", "41-796-87", "2022", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24.3", "24.3", "A", "", "89.0", "80.0", "", "58.5", "", "2", "", "", "102", "1", "2", "46", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "94", "13", "67", "50.0", "90.0", "98.6", "", "", "", "", "96.9"]} -{"pcdb_id": 19017, "brand_name": "Ideal Heating", "model_name": "LOGIC SYSTEM2", "model_qualifier": "S30", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 30.4, "final_year_of_manufacture": null, "raw": ["019017", "020099", "0", "2024/Dec/11 11:03", "Ideal Boilers", "Ideal Heating", "LOGIC SYSTEM2", "S30", "41-796-88", "2022", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "30.4", "30.4", "A", "", "88.9", "79.9", "", "58.3", "", "2", "", "", "102", "1", "2", "50", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "93", "12", "67", "50.0", "89.8", "98.2", "", "", "", "", "96.6"]} -{"pcdb_id": 19018, "brand_name": "Ideal Heating", "model_name": "LOGIC MAX COMBI2", "model_qualifier": "C24", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 88.2, "comparative_hot_water_efficiency_pct": 69.2, "output_kw_max": 24.2, "final_year_of_manufacture": null, "raw": ["019018", "020099", "0", "2024/Dec/11 10:13", "Ideal Boilers", "Ideal Heating", "LOGIC MAX COMBI2", "C24", "47-387-03", "2022", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "A", "", "89.0", "88.2", "", "69.2", "", "2", "", "", "104", "1", "2", "44", "2", "0", "", "", "", "0", "", "", "", "", "2", "7.615", "0.114", "0.0065", "1.4989", "13.2", "0.136", "0.0015", "1.42234", "0.00005", "0", "", "", "0035", "", "A", "82", "L", "94", "13", "66", "50.0", "90.0", "98.6", "", "", "", "", "96.9"]} -{"pcdb_id": 19019, "brand_name": "Ideal Heating", "model_name": "LOGIC MAX COMBI2", "model_qualifier": "C30", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 88.2, "comparative_hot_water_efficiency_pct": 69.7, "output_kw_max": 24.2, "final_year_of_manufacture": null, "raw": ["019019", "020099", "0", "2024/Dec/11 10:14", "Ideal Boilers", "Ideal Heating", "LOGIC MAX COMBI2", "C30", "47-387-04", "2022", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "A", "", "89.0", "88.2", "", "69.7", "", "2", "", "", "104", "1", "2", "28", "3", "0", "", "", "", "0", "", "", "", "", "2", "7.555", "0.114", "0.0055", "1.44658", "13.358", "0.133", "0.002", "1.37062", "0.00004", "0", "", "", "0035", "", "A", "81", "L", "94", "9", "54", "50.0", "90.0", "98.6", "", "", "", "", "96.9"]} -{"pcdb_id": 19020, "brand_name": "Ideal Heating", "model_name": "LOGIC MAX COMBI2", "model_qualifier": "C35", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 86.7, "comparative_hot_water_efficiency_pct": 69.4, "output_kw_max": 24.2, "final_year_of_manufacture": null, "raw": ["019020", "020099", "0", "2024/Dec/11 10:14", "Ideal Boilers", "Ideal Heating", "LOGIC MAX COMBI2", "C35", "47-387-05", "2022", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "A", "", "89.0", "86.7", "", "69.4", "", "2", "", "", "104", "1", "2", "28", "2", "0", "", "", "", "0", "", "", "", "", "2", "7.593", "0.117", "0.005", "1.48634", "13.633", "0.137", "0.0025", "1.28345", "0.00003", "0", "", "", "0035", "", "A", "79", "L", "94", "26", "85", "50.0", "90.0", "98.6", "", "", "", "", "96.9"]} -{"pcdb_id": 19021, "brand_name": "Ideal Heating", "model_name": "LOGIC MAX SYSTEM2", "model_qualifier": "S15", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 15.0, "final_year_of_manufacture": null, "raw": ["019021", "020099", "0", "2024/Dec/11 10:20", "Ideal Boilers", "Ideal Heating", "LOGIC MAX SYSTEM2", "S15", "41-796-97", "2022", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "15", "15", "A", "", "88.7", "79.7", "", "58.2", "", "2", "", "", "102", "1", "2", "20", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "93", "3", "30", "50.0", "90.0", "97.8", "", "", "", "", "96.4"]} -{"pcdb_id": 19022, "brand_name": "Ideal Heating", "model_name": "LOGIC MAX SYSTEM2", "model_qualifier": "S18", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 18.0, "final_year_of_manufacture": null, "raw": ["019022", "020099", "0", "2024/Dec/11 10:21", "Ideal Boilers", "Ideal Heating", "LOGIC MAX SYSTEM2", "S18", "41-796-98", "2022", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18", "18", "A", "", "89.0", "80.0", "", "58.4", "", "2", "", "", "102", "1", "2", "25", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "93", "23", "77", "50.0", "89.8", "98.5", "", "", "", "", "96.8"]} -{"pcdb_id": 19023, "brand_name": "Ideal Heating", "model_name": "LOGIC MAX SYSTEM2", "model_qualifier": "S24", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 24.2, "final_year_of_manufacture": null, "raw": ["019023", "020099", "0", "2024/Dec/11 10:21", "Ideal Boilers", "Ideal Heating", "LOGIC MAX SYSTEM2", "S24", "41-796-99", "2022", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24.2", "24.2", "A", "", "89.0", "80.0", "", "58.5", "", "2", "", "", "102", "1", "2", "44", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "94", "12", "64", "50.0", "90.0", "98.6", "", "", "", "", "96.9"]} -{"pcdb_id": 19024, "brand_name": "Ideal Heating", "model_name": "LOGIC MAX SYSTEM2", "model_qualifier": "S30", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 30.0, "final_year_of_manufacture": null, "raw": ["019024", "020099", "0", "2024/Dec/11 10:24", "Ideal Boilers", "Ideal Heating", "LOGIC MAX SYSTEM2", "S30", "41-860-01", "2022", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "30", "30", "A", "", "88.9", "79.9", "", "58.3", "", "2", "", "", "102", "1", "2", "52", "1", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "93", "12", "62", "50.0", "89.8", "98.2", "", "", "", "", "96.6"]} -{"pcdb_id": 19025, "brand_name": "Ideal Heating", "model_name": "LOGIC MAX HEAT2", "model_qualifier": "H12", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 12.0, "final_year_of_manufacture": null, "raw": ["019025", "020099", "0", "2024/Dec/11 10:15", "Ideal Boilers", "Ideal Heating", "LOGIC MAX HEAT2", "H12", "41-860-25", "2022", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "12", "12", "A", "", "88.8", "79.8", "", "58.3", "", "2", "", "", "102", "1", "2", "17", "1", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "93", "12", "42", "50.0", "90.0", "97.9", "", "", "", "", "96.4"]} -{"pcdb_id": 19026, "brand_name": "Ideal Heating", "model_name": "LOGIC MAX HEAT2", "model_qualifier": "H15", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 15.0, "final_year_of_manufacture": null, "raw": ["019026", "020099", "0", "2024/Dec/11 10:16", "Ideal Boilers", "Ideal Heating", "LOGIC MAX HEAT2", "H15", "41-860-26", "2022", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "15", "15", "A", "", "88.7", "79.7", "", "58.2", "", "2", "", "", "102", "1", "2", "20", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "93", "3", "30", "50.0", "90.0", "97.8", "", "", "", "", "96.4"]} -{"pcdb_id": 19027, "brand_name": "Ideal Heating", "model_name": "LOGIC MAX HEAT2", "model_qualifier": "H24", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 24.2, "final_year_of_manufacture": null, "raw": ["019027", "020099", "0", "2024/Dec/11 10:18", "Ideal Boilers", "Ideal Heating", "LOGIC MAX HEAT2", "H24", "41-860-28", "2022", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24.2", "24.2", "A", "", "89.0", "80.0", "", "58.5", "", "2", "", "", "102", "1", "2", "44", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "94", "12", "64", "50.0", "90.0", "98.6", "", "", "", "", "96.9"]} -{"pcdb_id": 19028, "brand_name": "Ideal Heating", "model_name": "LOGIC MAX HEAT2", "model_qualifier": "H30", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 30.0, "final_year_of_manufacture": null, "raw": ["019028", "020099", "0", "2024/Dec/11 10:18", "Ideal Boilers", "Ideal Heating", "LOGIC MAX HEAT2", "H30", "41-860-29", "2022", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "30", "30", "A", "", "88.8", "79.8", "", "58.3", "", "2", "", "", "102", "1", "2", "52", "1", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "93", "12", "62", "50.0", "89.6", "98.2", "", "", "", "", "96.6"]} -{"pcdb_id": 19029, "brand_name": "Ideal Heating", "model_name": "INDEPENDENT COMBI2", "model_qualifier": "C24", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 88.2, "comparative_hot_water_efficiency_pct": 70.0, "output_kw_max": 24.2, "final_year_of_manufacture": null, "raw": ["019029", "020099", "0", "2022/Oct/17 17:06", "Ideal Boilers", "Ideal Heating", "INDEPENDENT COMBI2", "C24", "47-387-09", "2022", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "A", "", "89.0", "88.2", "", "70.0", "", "2", "", "", "104", "1", "2", "46", "2", "0", "", "", "", "0", "", "", "", "", "2", "7.518", "0.131", "0.0115", "1.37564", "13.292", "0.157", "0.0045", "1.30006", "0.00007", "0", "", "", "0015", "", "A", "81", "L", "94", "13", "67", "50.0", "90.0", "98.6", "", "", "", "", "96.9"]} -{"pcdb_id": 19030, "brand_name": "Ideal Heating", "model_name": "INDEPENDENT COMBI2", "model_qualifier": "C30", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 88.2, "comparative_hot_water_efficiency_pct": 70.9, "output_kw_max": 24.2, "final_year_of_manufacture": null, "raw": ["019030", "020099", "0", "2022/Oct/17 17:10", "Ideal Boilers", "Ideal Heating", "INDEPENDENT COMBI2", "C30", "47-387-10", "2022", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "A", "", "89.0", "88.2", "", "70.9", "", "2", "", "", "104", "1", "2", "27", "3", "0", "", "", "", "0", "", "", "", "", "2", "7.425", "0.137", "0.0045", "1.3264", "13.175", "0.157", "0.003", "1.25175", "0.00002", "0", "", "", "0015", "", "A", "81", "L", "94", "9", "53", "50.0", "90.0", "98.6", "", "", "", "", "96.9"]} -{"pcdb_id": 19031, "brand_name": "Ideal Heating", "model_name": "INDEPENDENT COMBI2", "model_qualifier": "C35", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 86.6, "comparative_hot_water_efficiency_pct": 69.3, "output_kw_max": 24.2, "final_year_of_manufacture": null, "raw": ["019031", "020099", "0", "2022/Oct/17 17:18", "Ideal Boilers", "Ideal Heating", "INDEPENDENT COMBI2", "C35", "47-387-11", "2022", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "A", "", "89.0", "86.6", "", "69.3", "", "2", "", "", "104", "1", "2", "26", "2", "0", "", "", "", "0", "", "", "", "", "2", "7.6", "0.136", "0.0135", "1.44344", "13.634", "0.158", "0.006", "1.23652", "0.00008", "0", "", "", "0015", "", "A", "79", "L", "94", "12", "53", "50.0", "90.0", "98.6", "", "", "", "", "96.9"]} -{"pcdb_id": 19032, "brand_name": "Ideal Heating", "model_name": "INDEPENDENT SYSTEM2", "model_qualifier": "S15", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 15.1, "final_year_of_manufacture": null, "raw": ["019032", "020099", "0", "2022/Oct/18 15:14", "Ideal Boilers", "Ideal Heating", "INDEPENDENT SYSTEM2", "S15", "41-860-06", "2022", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "15.1", "15.1", "A", "", "88.7", "79.7", "", "58.2", "", "2", "", "", "102", "1", "2", "22", "3", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0015", "", "", "", "", "93", "11", "55", "50.0", "90.0", "97.8", "", "", "", "", "96.4"]} -{"pcdb_id": 19033, "brand_name": "Ideal Heating", "model_name": "INDEPENDENT SYSTEM2", "model_qualifier": "S18", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 18.1, "final_year_of_manufacture": null, "raw": ["019033", "020099", "0", "2022/Oct/18 15:14", "Ideal Boilers", "Ideal Heating", "INDEPENDENT SYSTEM2", "S18", "41-860-07", "2022", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18.1", "18.1", "A", "", "89.0", "80.0", "", "58.4", "", "2", "", "", "102", "1", "2", "25", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0015", "", "", "", "", "94", "3", "33", "50.0", "89.8", "98.5", "", "", "", "", "96.8"]} -{"pcdb_id": 19034, "brand_name": "Ideal Heating", "model_name": "INDEPENDENT SYSTEM2", "model_qualifier": "S24", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 24.2, "final_year_of_manufacture": null, "raw": ["019034", "020099", "0", "2022/Oct/18 15:14", "Ideal Boilers", "Ideal Heating", "INDEPENDENT SYSTEM2", "S24", "41-860-08", "2022", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24.2", "24.2", "A", "", "89.0", "80.0", "", "58.5", "", "2", "", "", "102", "1", "2", "46", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0015", "", "", "", "", "94", "13", "67", "50.0", "90.0", "98.6", "", "", "", "", "96.9"]} -{"pcdb_id": 19035, "brand_name": "Ideal Heating", "model_name": "INDEPENDENT SYSTEM2", "model_qualifier": "S30", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 30.0, "final_year_of_manufacture": null, "raw": ["019035", "020099", "0", "2022/Oct/18 15:15", "Ideal Boilers", "Ideal Heating", "INDEPENDENT SYSTEM2", "S30", "41-860-09", "2022", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "30", "30", "A", "", "88.9", "79.9", "", "58.3", "", "2", "", "", "102", "1", "2", "50", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0015", "", "", "", "", "93", "12", "67", "50.0", "89.8", "98.2", "", "", "", "", "96.6"]} -{"pcdb_id": 19036, "brand_name": "Ideal Heating", "model_name": "LOGIC MAX HEAT2", "model_qualifier": "H18", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 18.0, "final_year_of_manufacture": null, "raw": ["019036", "020099", "0", "2024/Dec/11 10:17", "Ideal Boilers", "Ideal Heating", "LOGIC MAX HEAT2", "H18", "41-860-27", "2022", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18", "18", "A", "", "89.0", "80.0", "", "58.4", "", "2", "", "", "102", "1", "2", "25", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "93", "23", "77", "50.0", "89.8", "98.5", "", "", "", "", "96.8"]} -{"pcdb_id": 19037, "brand_name": "Ideal Heating", "model_name": "LOGIC+ COMBI2", "model_qualifier": "C24", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 88.2, "comparative_hot_water_efficiency_pct": 69.2, "output_kw_max": 24.2, "final_year_of_manufacture": null, "raw": ["019037", "020099", "0", "2024/Dec/11 11:06", "Ideal Boilers", "Ideal Heating", "LOGIC+ COMBI2", "C24", "47-349-99", "2022", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "A", "", "89.0", "88.2", "", "69.2", "", "2", "", "", "104", "1", "2", "44", "2", "0", "", "", "", "0", "", "", "", "", "2", "7.615", "0.114", "0.0065", "1.4989", "13.2", "0.136", "0.0015", "1.42234", "0.00005", "0", "", "", "0035", "", "A", "82", "L", "94", "13", "66", "50.0", "90.0", "98.6", "", "", "", "", "96.9"]} -{"pcdb_id": 19038, "brand_name": "Ideal Heating", "model_name": "LOGIC+ COMBI2", "model_qualifier": "C30", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 88.2, "comparative_hot_water_efficiency_pct": 69.7, "output_kw_max": 24.2, "final_year_of_manufacture": null, "raw": ["019038", "020099", "0", "2024/Dec/11 11:06", "Ideal Boilers", "Ideal Heating", "LOGIC+ COMBI2", "C30", "47-387-01", "2022", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "A", "", "89.0", "88.2", "", "69.7", "", "2", "", "", "104", "1", "2", "28", "3", "0", "", "", "", "0", "", "", "", "", "2", "7.555", "0.114", "0.0055", "1.44658", "13.358", "0.133", "0.002", "1.37062", "0.00004", "0", "", "", "0035", "", "A", "81", "L", "94", "9", "54", "50.0", "90.0", "98.6", "", "", "", "", "96.9"]} -{"pcdb_id": 19039, "brand_name": "Ideal Heating", "model_name": "LOGIC+ COMBI2", "model_qualifier": "C35", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 86.7, "comparative_hot_water_efficiency_pct": 69.4, "output_kw_max": 24.2, "final_year_of_manufacture": null, "raw": ["019039", "020099", "0", "2024/Dec/11 11:07", "Ideal Boilers", "Ideal Heating", "LOGIC+ COMBI2", "C35", "47-387-02", "2022", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "A", "", "89.0", "86.7", "", "69.4", "", "2", "", "", "104", "1", "2", "28", "2", "0", "", "", "", "0", "", "", "", "", "2", "7.593", "0.117", "0.005", "1.48634", "13.633", "0.137", "0.0025", "1.28345", "0.00003", "0", "", "", "0035", "", "A", "79", "L", "94", "26", "85", "50.0", "90.0", "98.6", "", "", "", "", "96.9"]} -{"pcdb_id": 19040, "brand_name": "Ideal Heating", "model_name": "LOGIC+ HEAT2", "model_qualifier": "H12", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 12.0, "final_year_of_manufacture": null, "raw": ["019040", "020099", "0", "2024/Dec/11 11:12", "Ideal Boilers", "Ideal Heating", "LOGIC+ HEAT2", "H12", "41-860-20", "2022", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "12", "12", "A", "", "88.8", "79.8", "", "58.3", "", "2", "", "", "102", "1", "2", "17", "1", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "93", "12", "42", "50.0", "90.0", "97.9", "", "", "", "", "96.4"]} -{"pcdb_id": 19041, "brand_name": "Ideal Heating", "model_name": "LOGIC+ HEAT2", "model_qualifier": "H15", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 15.1, "final_year_of_manufacture": null, "raw": ["019041", "020099", "0", "2024/Dec/11 11:12", "Ideal Boilers", "Ideal Heating", "LOGIC+ HEAT2", "H15", "41-860-21", "2022", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "15.1", "15.1", "A", "", "88.7", "79.7", "", "58.2", "", "2", "", "", "102", "1", "2", "20", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "93", "3", "30", "50.0", "90.0", "97.8", "", "", "", "", "96.4"]} -{"pcdb_id": 19042, "brand_name": "Ideal Heating", "model_name": "LOGIC+ HEAT2", "model_qualifier": "H18", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 18.1, "final_year_of_manufacture": null, "raw": ["019042", "020099", "0", "2024/Dec/11 11:13", "Ideal Boilers", "Ideal Heating", "LOGIC+ HEAT2", "H18", "41-860-22", "2022", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18.1", "18.1", "A", "", "89.0", "80.0", "", "58.4", "", "2", "", "", "102", "1", "2", "25", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "93", "23", "77", "50.0", "89.8", "98.5", "", "", "", "", "96.8"]} -{"pcdb_id": 19043, "brand_name": "Ideal Heating", "model_name": "LOGIC+ HEAT2", "model_qualifier": "H24", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 24.2, "final_year_of_manufacture": null, "raw": ["019043", "020099", "0", "2024/Dec/11 11:14", "Ideal Boilers", "Ideal Heating", "LOGIC+ HEAT2", "H24", "41-860-23", "2022", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24.2", "24.2", "A", "", "89.0", "80.0", "", "58.5", "", "2", "", "", "102", "1", "2", "44", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "94", "12", "64", "50.0", "90.0", "98.6", "", "", "", "", "96.9"]} -{"pcdb_id": 19044, "brand_name": "Ideal Heating", "model_name": "LOGIC+ HEAT2", "model_qualifier": "H30", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 30.0, "final_year_of_manufacture": null, "raw": ["019044", "020099", "0", "2024/Dec/11 11:15", "Ideal Boilers", "Ideal Heating", "LOGIC+ HEAT2", "H30", "41-860-24", "2022", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "30", "30", "A", "", "88.8", "79.8", "", "58.3", "", "2", "", "", "102", "1", "2", "52", "1", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "93", "12", "62", "50.0", "89.6", "98.2", "", "", "", "", "96.6"]} -{"pcdb_id": 19045, "brand_name": "Ideal Heating", "model_name": "LOGIC+ SYSTEM2", "model_qualifier": "S15", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 15.1, "final_year_of_manufacture": null, "raw": ["019045", "020099", "0", "2024/Dec/11 11:15", "Ideal Boilers", "Ideal Heating", "LOGIC+ SYSTEM2", "S15", "41-796-93", "2022", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "15.1", "15.1", "A", "", "88.7", "79.7", "", "58.2", "", "2", "", "", "102", "1", "2", "20", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "93", "3", "30", "50.0", "90.0", "97.8", "", "", "", "", "96.3"]} -{"pcdb_id": 19046, "brand_name": "Ideal Heating", "model_name": "LOGIC+ SYSTEM2", "model_qualifier": "S18", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 18.0, "final_year_of_manufacture": null, "raw": ["019046", "020099", "0", "2024/Dec/11 11:16", "Ideal Boilers", "Ideal Heating", "LOGIC+ SYSTEM2", "S18", "41-796-94", "2022", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18", "18", "A", "", "89.0", "80.0", "", "58.4", "", "2", "", "", "102", "1", "2", "25", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "94", "23", "77", "50.0", "89.8", "98.5", "", "", "", "", "96.8"]} -{"pcdb_id": 19047, "brand_name": "Ideal Heating", "model_name": "LOGIC+ SYSTEM2", "model_qualifier": "S24", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 24.2, "final_year_of_manufacture": null, "raw": ["019047", "020099", "0", "2024/Dec/11 11:16", "Ideal Boilers", "Ideal Heating", "LOGIC+ SYSTEM2", "S24", "41-796-95", "2022", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24.2", "24.2", "A", "", "89.0", "80.0", "", "58.5", "", "2", "", "", "102", "1", "2", "44", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "94", "12", "64", "50.0", "90.0", "98.6", "", "", "", "", "96.9"]} -{"pcdb_id": 19048, "brand_name": "Ideal Heating", "model_name": "LOGIC+ SYSTEM2", "model_qualifier": "S30", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 30.0, "final_year_of_manufacture": null, "raw": ["019048", "020099", "0", "2024/Dec/11 11:17", "Ideal Boilers", "Ideal Heating", "LOGIC+ SYSTEM2", "S30", "41-796-96", "2022", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "30", "30", "A", "", "88.9", "79.9", "", "58.3", "", "2", "", "", "102", "1", "2", "52", "1", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "93", "12", "62", "50.0", "89.8", "98.2", "", "", "", "", "96.6"]} -{"pcdb_id": 19049, "brand_name": "i-mini", "model_name": "i-mini2", "model_qualifier": "c24", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 88.2, "comparative_hot_water_efficiency_pct": 70.0, "output_kw_max": 24.2, "final_year_of_manufacture": null, "raw": ["019049", "020099", "0", "2022/Oct/20 08:17", "Ideal Boilers", "i-mini", "i-mini2", "c24", "47-387-15", "2022", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "A", "", "89.0", "88.2", "", "70.0", "", "2", "", "", "104", "1", "2", "46", "2", "0", "", "", "", "0", "", "", "", "", "2", "7.518", "0.131", "0.0115", "1.37564", "13.292", "0.157", "0.0045", "1.30006", "0.00007", "0", "", "", "0015", "", "A", "81", "L", "94", "13", "67", "50.0", "90.0", "98.6", "", "", "", "", "96.9"]} -{"pcdb_id": 19050, "brand_name": "i-mini", "model_name": "i-mini2", "model_qualifier": "c30", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 88.2, "comparative_hot_water_efficiency_pct": 70.9, "output_kw_max": 24.2, "final_year_of_manufacture": null, "raw": ["019050", "020099", "0", "2022/Oct/19 16:35", "Ideal Boilers", "i-mini", "i-mini2", "c30", "47-387-16", "2022", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "A", "", "89.0", "88.2", "", "70.9", "", "2", "", "", "104", "1", "2", "27", "3", "0", "", "", "", "0", "", "", "", "", "2", "7.425", "0.137", "0.0045", "1.3264", "13.175", "0.157", "0.003", "1.25175", "0.00002", "0", "", "", "0015", "", "A", "81", "L", "94", "10", "55", "50.0", "90.0", "98.6", "", "", "", "", "96.9"]} -{"pcdb_id": 19051, "brand_name": "Keston", "model_name": "KESTON COMBI2", "model_qualifier": "C30", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 88.2, "comparative_hot_water_efficiency_pct": 69.7, "output_kw_max": 24.2, "final_year_of_manufacture": null, "raw": ["019051", "020099", "0", "2022/Oct/19 16:27", "Ideal Boilers", "Keston", "KESTON COMBI2", "C30", "47-830-09", "2022", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "A", "", "89.0", "88.2", "", "69.7", "", "2", "", "", "104", "1", "2", "28", "3", "0", "", "", "", "0", "", "", "", "", "2", "7.555", "0.114", "0.0055", "1.44658", "13.358", "0.133", "0.002", "1.37062", "0.00004", "0", "", "", "0015", "", "A", "81", "L", "94", "9", "54", "50.0", "90.0", "98.6", "", "", "", "", "96.9"]} -{"pcdb_id": 19052, "brand_name": "Keston", "model_name": "KESTON COMBI2", "model_qualifier": "C35", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 86.7, "comparative_hot_water_efficiency_pct": 69.4, "output_kw_max": 24.2, "final_year_of_manufacture": null, "raw": ["019052", "020099", "0", "2022/Oct/19 16:26", "Ideal Boilers", "Keston", "KESTON COMBI2", "C35", "47-930-10", "2022", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "A", "", "89.0", "86.7", "", "69.4", "", "2", "", "", "104", "1", "2", "28", "2", "0", "", "", "", "0", "", "", "", "", "2", "7.593", "0.117", "0.005", "1.48634", "13.633", "0.137", "0.0025", "1.28345", "0.00003", "0", "", "", "0015", "", "A", "79", "L", "94", "26", "85", "50.0", "90.0", "98.6", "", "", "", "", "96.9"]} -{"pcdb_id": 19053, "brand_name": "Keston", "model_name": "KESTON SYSTEM2", "model_qualifier": "S30", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 30.0, "final_year_of_manufacture": null, "raw": ["019053", "020099", "0", "2022/Oct/19 12:32", "Ideal Boilers", "Keston", "KESTON SYSTEM2", "S30", "41-930-54", "2022", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "30", "30", "A", "", "88.9", "79.9", "", "58.3", "", "2", "", "", "102", "1", "2", "52", "1", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0015", "", "", "", "", "93", "12", "62", "50.0", "89.8", "98.2", "", "", "", "", "96.6"]} -{"pcdb_id": 19054, "brand_name": "i-mini", "model_name": "i-mini2", "model_qualifier": "c35", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 86.6, "comparative_hot_water_efficiency_pct": 69.3, "output_kw_max": 24.2, "final_year_of_manufacture": null, "raw": ["019054", "020099", "0", "2022/Oct/20 08:47", "Ideal Boilers", "i-mini", "i-mini2", "c35", "47-387-17", "2022", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "A", "", "89.0", "86.6", "", "69.3", "", "2", "", "", "104", "1", "2", "26", "2", "0", "", "", "", "0", "", "", "", "", "2", "7.6", "0.136", "0.0135", "1.44344", "13.634", "0.158", "0.006", "1.23652", "0.00008", "0", "", "", "0015", "", "A", "79", "L", "94", "12", "53", "50.0", "90.0", "98.6", "", "", "", "", "96.9"]} -{"pcdb_id": 19055, "brand_name": "Vokera By Riello", "model_name": "UNICA MAX", "model_qualifier": "35C", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 86.7, "comparative_hot_water_efficiency_pct": 77.0, "output_kw_max": 32.0, "final_year_of_manufacture": null, "raw": ["019055", "020088", "0", "2023/Jan/25 17:08", "Vokera Ltd.", "Vokera By Riello", "UNICA MAX", "35C", "47-364-61", "2021", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "32", "32", "A", "", "88.7", "86.7", "", "77.0", "", "2", "", "", "104", "1", "2", "49", "3", "0", "", "", "", "0", "", "", "", "", "1", "6.841", "0.104", "0.0003", "0.73338", "", "", "", "", "", "0", "", "", "0025", "", "A", "85", "XL", "94", "13", "75", "26.0", "87.9", "98.7", "", "", "", "", "96.6"]} -{"pcdb_id": 19056, "brand_name": "SIME", "model_name": "MIA-", "model_qualifier": "30", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 88.2, "comparative_hot_water_efficiency_pct": 72.4, "output_kw_max": 23.9, "final_year_of_manufacture": null, "raw": ["019056", "020132", "0", "2023/Jan/04 09:07", "FONDERIE SIME SPA", "SIME", "MIA-", "30", "47-283-90", "2022", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "4.4", "23.9", "A", "", "88.5", "88.2", "", "72.4", "", "2", "", "", "104", "1", "2", "43", "4", "0", "", "", "", "0", "", "", "", "", "2", "7.275", "0.135", "0.0018", "1.16098", "13.068", "0.194", "0.0011", "1.12352", "0.00001", "0", "0", "", "0025", "", "A", "86", "XL", "93", "12", "75", "82.0", "88.7", "97.8", "", "", "", "", "96.0"]} -{"pcdb_id": 19057, "brand_name": "Vokera By Riello", "model_name": "UNICA MAX", "model_qualifier": "40C", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 86.7, "comparative_hot_water_efficiency_pct": 77.2, "output_kw_max": 32.0, "final_year_of_manufacture": null, "raw": ["019057", "020088", "0", "2023/Jan/26 09:13", "Vokera Ltd.", "Vokera By Riello", "UNICA MAX", "40C", "47-364-62", "2021", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "32", "32", "A", "", "88.7", "86.7", "", "77.2", "", "2", "", "", "104", "1", "2", "49", "3", "0", "", "", "", "0", "", "", "", "", "1", "6.821", "0.115", "0.0025", "0.70128", "", "", "", "", "", "0", "", "", "0025", "", "A", "85", "XL", "94", "13", "75", "26.0", "87.9", "98.7", "", "", "", "", "96.6"]} -{"pcdb_id": 19058, "brand_name": "Vokera By Riello", "model_name": "evolve", "model_qualifier": "24C", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 56.3, "output_kw_max": 17.6, "final_year_of_manufacture": null, "raw": ["019058", "020088", "0", "2023/Jan/05 15:32", "Vokera Ltd.", "Vokera By Riello", "evolve", "24C", "47 364 56", "2017", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "5.03", "17.6", "A", "", "88.7", "80.1", "", "56.3", "", "2", "0", "2", "104", "1", "2", "28", "3", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "0", "", "0005", "", "A", "87", "XL", "94", "14", "65", "42.0", "90.0", "95.5", "", "", "", "", "94.5"]} -{"pcdb_id": 19059, "brand_name": "Vokera By Riello", "model_name": "Easi-Heat Plus", "model_qualifier": "29Ci", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 56.8, "output_kw_max": 5.9, "final_year_of_manufacture": null, "raw": ["019059", "020088", "0", "2023/Jan/09 13:18", "Vokera Ltd.", "Vokera By Riello", "Easi-Heat Plus", "29Ci", "47-364-48", "2019", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "5.9", "5.9", "A", "", "89.4", "80.8", "", "56.8", "", "2", "0", "2", "104", "1", "2", "38", "5.6", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "0", "", "0025", "", "A", "84", "XL", "93", "15.3", "89", "35.0", "90.1", "97.3", "", "017896", "", "", "96.0"]} -{"pcdb_id": 19060, "brand_name": "Viessmann", "model_name": "VITODENS 200-W", "model_qualifier": "B2HA-60", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 55.4, "final_year_of_manufacture": null, "raw": ["019060", "020094", "0", "2023/Feb/21 18:50", "Viessmann Ltd", "Viessmann", "VITODENS 200-W", "B2HA-60", "", "2015", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "55.4", "55.4", "A", "", "88.8", "79.8", "", "58.3", "", "2", "", "", "102", "1", "2", "69", "4", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "2005", "", "", "", "", "94", "20", "107", "60.0", "88.6", "98.6", "", "", "", "", "96.7"]} -{"pcdb_id": 19061, "brand_name": "Ideal Heating", "model_name": "LOGIC HEAT2", "model_qualifier": "H18P", "winter_efficiency_pct": 90.0, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 59.2, "output_kw_max": 18.0, "final_year_of_manufacture": null, "raw": ["019061", "020099", "0", "2023/Mar/22 15:08", "Ideal Boilers", "Ideal Heating", "LOGIC HEAT2", "H18P", "41-860-12", "2022", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "18", "18", "A", "", "90.0", "81.0", "", "59.2", "", "2", "1", "", "102", "1", "2", "25", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0015", "", "", "", "", "93", "4", "35", "50.0", "91.8", "100.7", "", "", "", "", "99.0"]} -{"pcdb_id": 19062, "brand_name": "Ideal Heating", "model_name": "LOGIC HEAT2", "model_qualifier": "H24P", "winter_efficiency_pct": 90.1, "summer_efficiency_pct": 81.1, "comparative_hot_water_efficiency_pct": 59.2, "output_kw_max": 24.2, "final_year_of_manufacture": null, "raw": ["019062", "020099", "0", "2023/Mar/22 14:35", "Ideal Boilers", "Ideal Heating", "LOGIC HEAT2", "H24P", "41-860-13", "2022", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "24.2", "24.2", "A", "", "90.1", "81.1", "", "59.2", "", "2", "1", "", "102", "1", "2", "46", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0015", "", "", "", "", "94", "13", "67", "50.0", "92.0", "100.8", "", "", "", "", "99.1"]} -{"pcdb_id": 19063, "brand_name": "Ideal Heating", "model_name": "LOGIC HEAT2", "model_qualifier": "H30P", "winter_efficiency_pct": 89.9, "summer_efficiency_pct": 80.9, "comparative_hot_water_efficiency_pct": 59.1, "output_kw_max": 30.0, "final_year_of_manufacture": null, "raw": ["019063", "020099", "0", "2023/Mar/22 14:34", "Ideal Boilers", "Ideal Heating", "LOGIC HEAT2", "H30P", "41-860-14", "2022", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "30", "30", "A", "", "89.9", "80.9", "", "59.1", "", "2", "1", "", "102", "1", "2", "50", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0015", "", "", "", "", "93", "12", "67", "50.0", "91.8", "100.4", "", "", "", "", "98.8"]} -{"pcdb_id": 19064, "brand_name": "Ideal Heating", "model_name": "LOGIC MAX HEAT2", "model_qualifier": "H18P", "winter_efficiency_pct": 90.0, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 59.2, "output_kw_max": 18.0, "final_year_of_manufacture": null, "raw": ["019064", "020099", "0", "2023/Mar/22 14:34", "Ideal Boilers", "Ideal Heating", "LOGIC MAX HEAT2", "H18P", "41-860-27", "2022", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "18", "18", "A", "", "90.0", "81.0", "", "59.2", "", "2", "1", "", "102", "1", "2", "25", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0015", "", "", "", "", "93", "23", "77", "50.0", "91.8", "100.7", "", "", "", "", "99.0"]} -{"pcdb_id": 19065, "brand_name": "Ideal Heating", "model_name": "LOGIC MAX HEAT2", "model_qualifier": "H24P", "winter_efficiency_pct": 90.1, "summer_efficiency_pct": 81.1, "comparative_hot_water_efficiency_pct": 59.2, "output_kw_max": 24.2, "final_year_of_manufacture": null, "raw": ["019065", "020099", "0", "2023/Mar/22 14:33", "Ideal Boilers", "Ideal Heating", "LOGIC MAX HEAT2", "H24P", "41-860-28", "2022", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "24.2", "24.2", "A", "", "90.1", "81.1", "", "59.2", "", "2", "1", "", "102", "1", "2", "44", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0015", "", "", "", "", "94", "12", "64", "50.0", "92.0", "100.8", "", "", "", "", "99.1"]} -{"pcdb_id": 19066, "brand_name": "Ideal Heating", "model_name": "LOGIC MAX HEAT2", "model_qualifier": "H30P", "winter_efficiency_pct": 89.8, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 59.1, "output_kw_max": 30.0, "final_year_of_manufacture": null, "raw": ["019066", "020099", "0", "2023/Mar/22 14:33", "Ideal Boilers", "Ideal Heating", "LOGIC MAX HEAT2", "H30P", "41-860-29", "2022", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "30", "30", "A", "", "89.8", "80.8", "", "59.1", "", "2", "1", "", "102", "1", "2", "52", "1", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0015", "", "", "", "", "93", "12", "62", "50.0", "91.6", "100.4", "", "", "", "", "98.7"]} -{"pcdb_id": 19067, "brand_name": "Ideal Heating", "model_name": "LOGIC SYSTEM2", "model_qualifier": "S18P", "winter_efficiency_pct": 90.0, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 59.2, "output_kw_max": 18.0, "final_year_of_manufacture": null, "raw": ["019067", "020099", "0", "2023/Mar/22 14:33", "Ideal Boilers", "Ideal Heating", "LOGIC SYSTEM2", "S18P", "41-796-86", "2022", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "18", "18", "A", "", "90.0", "81.0", "", "59.2", "", "2", "1", "", "102", "1", "2", "25", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0015", "", "", "", "", "93", "3", "33", "50.0", "91.8", "100.7", "", "", "", "", "99.0"]} -{"pcdb_id": 19068, "brand_name": "Ideal Heating", "model_name": "LOGIC SYSTEM2", "model_qualifier": "S30P", "winter_efficiency_pct": 89.9, "summer_efficiency_pct": 80.9, "comparative_hot_water_efficiency_pct": 59.1, "output_kw_max": 30.0, "final_year_of_manufacture": null, "raw": ["019068", "020099", "0", "2023/Mar/22 14:31", "Ideal Boilers", "Ideal Heating", "LOGIC SYSTEM2", "S30P", "41-796-88", "2022", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "30", "30", "A", "", "89.9", "80.9", "", "59.1", "", "2", "1", "", "102", "1", "2", "50", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0015", "", "", "", "", "93", "12", "67", "50.0", "91.8", "100.4", "", "", "", "", "98.8"]} -{"pcdb_id": 19069, "brand_name": "Ideal Heating", "model_name": "LOGIC MAX SYSTEM2", "model_qualifier": "S18P", "winter_efficiency_pct": 90.0, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 59.2, "output_kw_max": 18.0, "final_year_of_manufacture": null, "raw": ["019069", "020099", "0", "2023/Mar/22 14:30", "Ideal Boilers", "Ideal Heating", "LOGIC MAX SYSTEM2", "S18P", "41-796-98", "2022", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "18", "18", "A", "", "90.0", "81.0", "", "59.2", "", "2", "1", "", "102", "1", "2", "25", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0015", "", "", "", "", "93", "23", "77", "50.0", "91.8", "100.7", "", "", "", "", "99.0"]} -{"pcdb_id": 19070, "brand_name": "Ideal Heating", "model_name": "LOGIC MAX SYSTEM2", "model_qualifier": "S24P", "winter_efficiency_pct": 90.1, "summer_efficiency_pct": 81.1, "comparative_hot_water_efficiency_pct": 59.2, "output_kw_max": 24.3, "final_year_of_manufacture": null, "raw": ["019070", "020099", "0", "2023/Mar/22 14:30", "Ideal Boilers", "Ideal Heating", "LOGIC MAX SYSTEM2", "S24P", "41-796-99", "2022", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "24.3", "24.3", "A", "", "90.1", "81.1", "", "59.2", "", "2", "1", "", "102", "1", "2", "44", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0015", "", "", "", "", "94", "12", "64", "50.0", "92.0", "100.8", "", "", "", "", "99.1"]} -{"pcdb_id": 19071, "brand_name": "Ideal Heating", "model_name": "LOGIC MAX SYSTEM2", "model_qualifier": "S30P", "winter_efficiency_pct": 89.8, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 59.0, "output_kw_max": 30.0, "final_year_of_manufacture": null, "raw": ["019071", "020099", "0", "2023/Mar/22 14:29", "Ideal Boilers", "Ideal Heating", "LOGIC MAX SYSTEM2", "S30P", "41-860-01", "2022", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "30", "30", "A", "", "89.8", "80.8", "", "59.0", "", "2", "1", "", "102", "1", "2", "52", "1", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0015", "", "", "", "", "93", "12", "62", "50.0", "91.8", "100.3", "", "", "", "", "98.7"]} -{"pcdb_id": 19072, "brand_name": "SIME", "model_name": "GIULIA COMBI", "model_qualifier": "30", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 76.3, "comparative_hot_water_efficiency_pct": 72.8, "output_kw_max": 30.0, "final_year_of_manufacture": null, "raw": ["019072", "020132", "0", "2023/Mar/31 10:32", "FONDERIE SIME SPA", "SIME", "GIULIA COMBI", "30", "47-283-93", "2023", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "4.8", "30", "A", "", "88.6", "76.3", "", "72.8", "", "2", "", "", "104", "1", "2", "35", "4", "0", "", "", "", "0", "", "", "", "", "2", "7.235", "0.149", "0.0099", "1.07739", "14.109", "0.175", "0.006", "0.10228", "0.00004", "0", "", "", "0025", "", "A", "82", "XL", "93", "11", "68", "82.0", "88.7", "97.9", "", "", "", "", "96.2"]} -{"pcdb_id": 19073, "brand_name": "SIME", "model_name": "GIULIA SYSTEM", "model_qualifier": "25", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 24.0, "final_year_of_manufacture": null, "raw": ["019073", "020132", "0", "2023/Mar/31 10:37", "FONDERIE SIME SPA", "SIME", "GIULIA SYSTEM", "25", "41-283-66", "2023", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "4.8", "24", "A", "", "88.6", "79.6", "", "58.1", "", "2", "", "", "102", "1", "2", "35", "4", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "93", "11", "68", "82.0", "88.7", "97.9", "", "", "", "", "96.2"]} -{"pcdb_id": 19074, "brand_name": "Sapphire", "model_name": "Sapphire 28 HVO", "model_qualifier": "", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 81.1, "comparative_hot_water_efficiency_pct": 59.2, "output_kw_max": 28.0, "final_year_of_manufacture": null, "raw": ["019074", "020153", "0", "2023/May/11 17:16", "EOGB Energy Products ltd", "Sapphire", "Sapphire 28 HVO", "", "", "2021", "current", "71", "1", "1", "1", "0", "", "", "2", "2", "2", "28", "28", "A", "", "88.9", "81.1", "", "59.2", "", "2", "", "", "201", "1", "2", "117", "6", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "4015", "", "", "", "", "93", "27", "162", "49.0", "91.5", "96.8", "", "018903", "", "", "95.8"]} -{"pcdb_id": 19075, "brand_name": "Sapphire", "model_name": "Sapphire 23 HVO", "model_qualifier": "", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 80.9, "comparative_hot_water_efficiency_pct": 59.1, "output_kw_max": 23.4, "final_year_of_manufacture": null, "raw": ["019075", "020153", "0", "2023/May/11 17:22", "EOGB Energy Products ltd", "Sapphire", "Sapphire 23 HVO", "", "", "2021", "current", "71", "1", "1", "1", "0", "", "", "2", "2", "2", "7.08", "23.4", "A", "", "88.7", "80.9", "", "59.1", "", "2", "", "", "201", "1", "2", "133", "6", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "4005", "", "", "", "", "92", "27", "172", "49.0", "92.6", "95.9", "", "018906", "", "", "95.2"]} -{"pcdb_id": 19076, "brand_name": "Baxi", "model_name": "624 COMBI 2", "model_qualifier": "", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 86.8, "comparative_hot_water_efficiency_pct": 80.4, "output_kw_max": 22.9, "final_year_of_manufacture": null, "raw": ["019076", "020101", "0", "2023/Jun/27 14:55", "Baxi Heating", "Baxi", "624 COMBI 2", "", "47-077-55", "2023", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "22.9", "22.9", "A", "", "88.9", "86.8", "", "80.4", "", "2", "", "", "104", "1", "2", "46", "4", "0", "", "", "", "0", "", "", "", "", "1", "6.548", "0.074", "0.0029", "0.44307", "", "", "", "", "", "0", "", "", "0405", "", "A", "93", "XL", "94", "8", "68", "40.0", "88.2", "99.0", "", "", "", "", "97.0"]} -{"pcdb_id": 19077, "brand_name": "Baxi", "model_name": "630 COMBI 2", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 86.7, "comparative_hot_water_efficiency_pct": 81.3, "output_kw_max": 28.6, "final_year_of_manufacture": null, "raw": ["019077", "020101", "0", "2023/Jun/27 15:46", "Baxi Heating", "Baxi", "630 COMBI 2", "", "47-077-56", "2023", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28.6", "28.6", "A", "", "88.8", "86.7", "", "81.3", "", "2", "", "", "104", "1", "2", "61", "4", "0", "", "", "", "0", "", "", "", "", "1", "6.474", "0.071", "0.0021", "0.37197", "", "", "", "", "", "0", "", "", "0405", "", "A", "93", "XL", "94", "9", "79", "40.0", "88.0", "98.9", "", "", "", "", "96.9"]} -{"pcdb_id": 19078, "brand_name": "Baxi", "model_name": "636 COMBI 2", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 86.7, "comparative_hot_water_efficiency_pct": 81.4, "output_kw_max": 28.6, "final_year_of_manufacture": null, "raw": ["019078", "020101", "0", "2023/Jun/27 14:53", "Baxi Heating", "Baxi", "636 COMBI 2", "", "47-077-57", "2023", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28.6", "28.6", "A", "", "88.8", "86.7", "", "81.4", "", "2", "", "", "104", "1", "2", "71", "4", "0", "", "", "", "0", "", "", "", "", "1", "6.47", "0.071", "0.0021", "0.37024", "", "", "", "", "", "0", "", "", "0405", "", "A", "93", "XL", "94", "9", "85", "40.0", "88.1", "98.8", "", "", "", "", "96.8"]} -{"pcdb_id": 19079, "brand_name": "Baxi", "model_name": "ASSURE 524 COMBI 2", "model_qualifier": "", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 86.8, "comparative_hot_water_efficiency_pct": 80.4, "output_kw_max": 22.9, "final_year_of_manufacture": null, "raw": ["019079", "020101", "0", "2023/Jun/27 14:52", "Baxi Heating", "Baxi", "ASSURE 524 COMBI 2", "", "47-077-59", "2023", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "22.9", "22.9", "A", "", "88.9", "86.8", "", "80.4", "", "2", "", "", "104", "1", "2", "46", "4", "0", "", "", "", "0", "", "", "", "", "1", "6.548", "0.074", "0.0029", "0.44307", "", "", "", "", "", "0", "", "", "0405", "", "A", "93", "XL", "94", "8", "68", "40.0", "88.2", "99.0", "", "", "", "", "97.0"]} -{"pcdb_id": 19080, "brand_name": "Baxi", "model_name": "ASSURE 530 COMBI 2", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 86.7, "comparative_hot_water_efficiency_pct": 81.3, "output_kw_max": 28.6, "final_year_of_manufacture": null, "raw": ["019080", "020101", "0", "2023/Jun/27 14:47", "Baxi Heating UK Ltd", "Baxi", "ASSURE 530 COMBI 2", "", "47-077-60", "2023", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28.6", "28.6", "A", "", "88.8", "86.7", "", "81.3", "", "2", "", "", "104", "1", "2", "61", "4", "0", "", "", "", "0", "", "", "", "", "1", "6.474", "0.071", "0.0021", "0.37197", "", "", "", "", "", "0", "", "", "0405", "", "A", "93", "XL", "94", "9", "79", "40.0", "88.0", "98.9", "", "", "", "", "96.9"]} -{"pcdb_id": 19081, "brand_name": "Baxi", "model_name": "ASSURE 536 COMBI 2", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 86.7, "comparative_hot_water_efficiency_pct": 81.4, "output_kw_max": 28.6, "final_year_of_manufacture": null, "raw": ["019081", "020101", "0", "2023/Jun/27 14:59", "Baxi Heating UK Ltd", "Baxi", "ASSURE 536 COMBI 2", "", "47-077-61", "2023", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28.6", "28.6", "A", "", "88.8", "86.7", "", "81.4", "", "2", "", "", "104", "1", "2", "71", "4", "0", "", "", "", "0", "", "", "", "", "1", "6.47", "0.071", "0.0021", "0.37024", "", "", "", "", "", "0", "", "", "0405", "", "A", "93", "XL", "94", "9", "85", "40.0", "88.1", "98.8", "", "", "", "", "96.8"]} -{"pcdb_id": 19082, "brand_name": "Baxi", "model_name": "824 COMBI 2", "model_qualifier": "", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 86.8, "comparative_hot_water_efficiency_pct": 80.4, "output_kw_max": 22.9, "final_year_of_manufacture": null, "raw": ["019082", "020101", "0", "2023/Jun/27 15:01", "Baxi Heating UK Ltd", "Baxi", "824 COMBI 2", "", "47-077-63", "2023", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "22.9", "22.9", "A", "", "88.9", "86.8", "", "80.4", "", "2", "", "", "104", "1", "2", "46", "4", "0", "", "", "", "0", "", "", "", "", "1", "6.548", "0.074", "0.0029", "0.44307", "", "", "", "", "", "0", "", "", "0405", "", "A", "93", "XL", "94", "8", "68", "40.0", "88.2", "99.0", "", "", "", "", "97.0"]} -{"pcdb_id": 19083, "brand_name": "Baxi", "model_name": "830 COMBI 2", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 86.7, "comparative_hot_water_efficiency_pct": 81.3, "output_kw_max": 28.6, "final_year_of_manufacture": null, "raw": ["019083", "020101", "0", "2023/Jun/27 15:04", "Baxi Heating UK Ltd", "Baxi", "830 COMBI 2", "", "47-077-64", "2023", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28.6", "28.6", "A", "", "88.8", "86.7", "", "81.3", "", "2", "", "", "104", "1", "2", "61", "4", "0", "", "", "", "0", "", "", "", "", "1", "6.474", "0.071", "0.0021", "0.37197", "", "", "", "", "", "0", "", "", "0405", "", "A", "93", "XL", "94", "9", "79", "40.0", "88.0", "98.9", "", "", "", "", "96.9"]} -{"pcdb_id": 19084, "brand_name": "Baxi", "model_name": "836 COMBI 2", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 86.7, "comparative_hot_water_efficiency_pct": 81.4, "output_kw_max": 28.6, "final_year_of_manufacture": null, "raw": ["019084", "020101", "0", "2023/Jun/27 15:45", "Baxi Heating UK Ltd", "Baxi", "836 COMBI 2", "", "47-077-65", "2023", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28.6", "28.6", "A", "", "88.8", "86.7", "", "81.4", "", "2", "", "", "104", "1", "2", "71", "4", "0", "", "", "", "0", "", "", "", "", "1", "6.47", "0.071", "0.0021", "0.37024", "", "", "", "", "", "0", "", "", "0405", "", "A", "93", "XL", "94", "9", "85", "40.0", "88.1", "98.8", "", "", "", "", "96.8"]} -{"pcdb_id": 19085, "brand_name": "Baxi", "model_name": "615 SYSTEM 2", "model_qualifier": "", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 17.2, "final_year_of_manufacture": null, "raw": ["019085", "020101", "0", "2023/Jun/27 15:08", "Baxi Heating UK Ltd", "Baxi", "615 SYSTEM 2", "", "41-884-01", "2023", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "17.2", "17.2", "A", "", "88.9", "79.9", "", "58.4", "", "2", "", "", "102", "1", "2", "16", "4", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "94", "8", "51", "40.0", "88.2", "99.0", "", "", "", "", "97.0"]} -{"pcdb_id": 19086, "brand_name": "Baxi", "model_name": "618 SYSTEM 2", "model_qualifier": "", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 20.7, "final_year_of_manufacture": null, "raw": ["019086", "020101", "0", "2023/Jun/27 15:14", "Baxi Heating UK Ltd", "Baxi", "618 SYSTEM 2", "", "41-884-02", "2023", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "20.7", "20.7", "A", "", "88.9", "79.9", "", "58.4", "", "2", "", "", "102", "1", "2", "26", "4", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "94", "8", "56", "40.0", "88.2", "99.0", "", "", "", "", "97.0"]} -{"pcdb_id": 19087, "brand_name": "Baxi", "model_name": "624 SYSTEM 2", "model_qualifier": "", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 27.4, "final_year_of_manufacture": null, "raw": ["019087", "020101", "0", "2023/Jun/27 15:16", "Baxi Heating UK Ltd", "Baxi", "624 SYSTEM 2", "", "41-884-03", "2023", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "27.4", "27.4", "A", "", "88.9", "79.9", "", "58.4", "", "2", "", "", "102", "1", "2", "46", "4", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "94", "8", "68", "40.0", "88.2", "99.0", "", "", "", "", "97.0"]} -{"pcdb_id": 19088, "brand_name": "Baxi", "model_name": "818 SYSTEM 2", "model_qualifier": "", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 20.7, "final_year_of_manufacture": null, "raw": ["019088", "020101", "0", "2023/Jun/27 15:18", "Baxi Heating UK Ltd", "Baxi", "818 SYSTEM 2", "", "41-470-99", "2023", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "20.7", "20.7", "A", "", "88.9", "79.9", "", "58.4", "", "2", "", "", "102", "1", "2", "26", "4", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "94", "8", "56", "40.0", "88.2", "99.0", "", "", "", "", "97.0"]} -{"pcdb_id": 19089, "brand_name": "Baxi", "model_name": "824 SYSTEM 2", "model_qualifier": "", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 27.4, "final_year_of_manufacture": null, "raw": ["019089", "020101", "0", "2023/Jun/27 15:20", "Baxi Heating UK Ltd", "Baxi", "824 SYSTEM 2", "", "41-884-09", "2023", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "27.4", "27.4", "A", "", "88.9", "79.9", "", "58.4", "", "2", "", "", "102", "1", "2", "46", "4", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "94", "8", "68", "40.0", "88.2", "99.0", "", "", "", "", "97.0"]} -{"pcdb_id": 19090, "brand_name": "Baxi", "model_name": "830 SYSTEM 2", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 34.3, "final_year_of_manufacture": null, "raw": ["019090", "020101", "0", "2023/Jun/27 15:21", "Baxi Heating UK Ltd", "Baxi", "830 SYSTEM 2", "", "41-884-08", "2023", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "34.3", "34.3", "A", "", "88.8", "79.8", "", "58.3", "", "2", "", "", "102", "1", "2", "71", "4", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "94", "9", "85", "40.0", "87.9", "98.8", "", "", "", "", "96.8"]} -{"pcdb_id": 19091, "brand_name": "Baxi", "model_name": "ASSURE 515 SYSTEM 2", "model_qualifier": "", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 17.2, "final_year_of_manufacture": null, "raw": ["019091", "020101", "0", "2023/Jun/27 15:25", "Baxi Heating UK Ltd", "Baxi", "ASSURE 515 SYSTEM 2", "", "41-844-04", "2023", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "17.2", "17.2", "A", "", "88.9", "79.9", "", "58.4", "", "2", "", "", "102", "1", "2", "16", "4", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "94", "8", "51", "40.0", "88.2", "99.0", "", "", "", "", "97.0"]} -{"pcdb_id": 19092, "brand_name": "Baxi", "model_name": "ASSURE 518 SYSTEM 2", "model_qualifier": "", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 20.7, "final_year_of_manufacture": null, "raw": ["019092", "020101", "0", "2023/Jun/27 15:42", "Baxi Heating UK Ltd", "Baxi", "ASSURE 518 SYSTEM 2", "", "41-844-05", "2023", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "20.7", "20.7", "A", "", "88.9", "79.9", "", "58.4", "", "2", "", "", "102", "1", "2", "26", "4", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "94", "8", "56", "40.0", "88.2", "99.0", "", "", "", "", "97.0"]} -{"pcdb_id": 19093, "brand_name": "Baxi", "model_name": "ASSURE 524 SYSTEM 2", "model_qualifier": "", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 27.4, "final_year_of_manufacture": null, "raw": ["019093", "020101", "0", "2023/Jun/27 15:27", "Baxi Heating UK Ltd", "Baxi", "ASSURE 524 SYSTEM 2", "", "41-844-06", "2023", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "27.4", "27.4", "A", "", "88.9", "79.9", "", "58.4", "", "2", "", "", "102", "1", "2", "46", "4", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "94", "8", "68", "40.0", "88.2", "99.0", "", "", "", "", "97.0"]} -{"pcdb_id": 19094, "brand_name": "Worcester", "model_name": "Greenstar 2000", "model_qualifier": "GR2301iW 30 C NG", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 88.2, "comparative_hot_water_efficiency_pct": 70.2, "output_kw_max": 24.0, "final_year_of_manufacture": null, "raw": ["019094", "020051", "0", "2023/Jul/13 15:21", "Bosch Thermotechnology Ltd", "Worcester", "Greenstar 2000", "GR2301iW 30 C NG", "47-800-36", "2023", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "A", "", "88.7", "88.2", "", "70.2", "", "2", "", "", "104", "1", "2", "37", "3", "0", "", "", "", "0", "", "", "", "", "2", "7.502", "0.104", "0.0032", "1.35468", "13.279", "0.122", "0.0023", "1.33322", "0.00001", "0", "", "", "8305", "", "A", "84", "XL", "94", "12", "66", "55.0", "88.0", "98.6", "", "", "", "", "96.6"]} -{"pcdb_id": 19095, "brand_name": "Worcester", "model_name": "Greenstar 2000", "model_qualifier": "GR2301iW 25 C NG", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 88.2, "comparative_hot_water_efficiency_pct": 74.4, "output_kw_max": 24.0, "final_year_of_manufacture": null, "raw": ["019095", "020051", "0", "2023/Jul/13 15:21", "Bosch Thermotechnology Ltd", "Worcester", "Greenstar 2000", "GR2301iW 25 C NG", "47-800-34", "2023", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "A", "", "88.7", "88.2", "", "74.4", "", "2", "", "", "104", "1", "2", "37", "3", "0", "", "", "", "0", "", "", "", "", "2", "7.083", "0.103", "0.0048", "0.94216", "12.72", "0.124", "0.0016", "0.92191", "0.00003", "0", "", "", "8305", "", "A", "84", "XL", "94", "12", "66", "55.0", "88.0", "98.6", "", "", "", "", "96.6"]} -{"pcdb_id": 19096, "brand_name": "Worcester", "model_name": "Greenstar 2000", "model_qualifier": "GR2301iW 30 C LPG", "winter_efficiency_pct": 89.8, "summer_efficiency_pct": 90.3, "comparative_hot_water_efficiency_pct": 72.0, "output_kw_max": 24.0, "final_year_of_manufacture": null, "raw": ["019096", "020051", "0", "2023/Jul/13 15:22", "Bosch Thermotechnology Ltd", "Worcester", "Greenstar 2000", "GR2301iW 30 C LPG", "47-800-37", "2023", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "A", "", "89.8", "90.3", "", "72.0", "", "2", "0", "2", "104", "1", "2", "37", "3", "0", "", "", "", "0", "", "", "", "", "2", "7.476", "0.096", "0.0047", "1.31385", "13.022", "0.113", "0.0002", "1.31111", "0.00005", "0", "", "", "8305", "", "A", "84", "XL", "94", "12", "66", "55.0", "89.7", "98.5", "", "", "", "", "96.8"]} -{"pcdb_id": 19097, "brand_name": "Worcester", "model_name": "Greenstar 2000", "model_qualifier": "GR2301iW 25 C LPG", "winter_efficiency_pct": 89.8, "summer_efficiency_pct": 90.3, "comparative_hot_water_efficiency_pct": 74.2, "output_kw_max": 24.0, "final_year_of_manufacture": null, "raw": ["019097", "020051", "0", "2023/Jul/13 15:24", "Bosch Thermotechnology Ltd", "Worcester", "Greenstar 2000", "GR2301iW 25 C LPG", "47-800-35", "2023", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "A", "", "89.8", "90.3", "", "74.2", "", "2", "0", "2", "104", "1", "2", "37", "3", "0", "", "", "", "0", "", "", "", "", "2", "7.252", "0.094", "0.0004", "1.12367", "13.176", "0.113", "0.0013", "1.12102", "-0.00001", "", "", "", "8305", "", "A", "84", "XL", "94", "12", "66", "55.0", "89.7", "98.5", "", "", "", "", "96.8"]} -{"pcdb_id": 19098, "brand_name": "Vokera By Riello", "model_name": "evolve", "model_qualifier": "18S LPG", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 18.0, "final_year_of_manufacture": null, "raw": ["019098", "020088", "0", "2023/Aug/04 14:52", "Vokera Ltd.", "Vokera By Riello", "evolve", "18S LPG", "47-364-09", "2018", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "18", "18", "A", "", "88.7", "79.7", "", "58.2", "", "2", "0", "2", "102", "1", "2", "28", "3", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "94", "14", "65", "42.0", "90.0", "95.5", "", "", "", "", "94.5"]} -{"pcdb_id": 19099, "brand_name": "Alpha Innovation", "model_name": "E-Tec NX", "model_qualifier": "28", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 82.7, "comparative_hot_water_efficiency_pct": 69.5, "output_kw_max": 24.0, "final_year_of_manufacture": null, "raw": ["019099", "020029", "0", "2023/Aug/11 11:38", "Immergas", "Alpha Innovation", "E-Tec NX", "28", "3.033112", "2023", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "A", "", "88.8", "82.7", "", "69.5", "", "2", "", "", "104", "1", "2", "12", "2", "0", "", "", "", "0", "", "", "", "", "2", "7.576", "0.069", "0.0057", "1.41374", "13.894", "0.086", "0.0017", "0.93333", "0.00004", "0", "", "", "1005", "", "A", "87", "XL", "94", "6", "32", "54.0", "88.1", "98.7", "", "", "", "", "96.7"]} -{"pcdb_id": 19100, "brand_name": "Alpha Innovation", "model_name": "E-Tec NX", "model_qualifier": "33", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 70.3, "output_kw_max": 28.0, "final_year_of_manufacture": null, "raw": ["019100", "020029", "0", "2023/Aug/11 11:49", "Immergas", "Alpha Innovation", "E-Tec NX", "33", "3.033113", "2023", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28", "28", "A", "", "88.8", "79.9", "", "70.3", "", "2", "", "", "104", "1", "2", "13", "2", "0", "", "", "", "0", "", "", "", "", "2", "7.489", "0.077", "0.0021", "1.35105", "14.074", "0.1", "0.0035", "0.64996", "-0.00001", "0", "", "", "1005", "", "A", "87", "XL", "94", "6", "33", "54.0", "88.1", "98.7", "", "", "", "", "96.7"]} -{"pcdb_id": 19101, "brand_name": "Alpha Innovation", "model_name": "Evoke NX", "model_qualifier": "28", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 82.7, "comparative_hot_water_efficiency_pct": 69.5, "output_kw_max": 24.0, "final_year_of_manufacture": null, "raw": ["019101", "020029", "0", "2023/Aug/11 12:00", "Immergas", "Alpha Innovation", "Evoke NX", "28", "3.033114", "2023", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "A", "", "88.8", "82.7", "", "69.5", "", "2", "", "", "104", "1", "2", "12", "2", "0", "", "", "", "0", "", "", "", "", "2", "7.576", "0.069", "0.0057", "1.41374", "13.894", "0.086", "0.0018", "0.93401", "0.00004", "0", "", "", "1005", "", "A", "87", "XL", "94", "6", "32", "54.0", "88.1", "98.7", "", "", "", "", "96.7"]} -{"pcdb_id": 19102, "brand_name": "Alpha Innovation", "model_name": "Evoke NX", "model_qualifier": "33", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 70.3, "output_kw_max": 28.0, "final_year_of_manufacture": null, "raw": ["019102", "020029", "0", "2023/Aug/11 12:06", "Immergas", "Alpha Innovation", "Evoke NX", "33", "3.033115", "2023", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28", "28", "A", "", "88.8", "79.9", "", "70.3", "", "2", "", "", "104", "1", "2", "13", "2", "0", "", "", "", "0", "", "", "", "", "2", "7.489", "0.077", "0.0021", "1.35105", "14.074", "0.1", "0.0035", "0.64996", "-0.00001", "", "", "", "1005", "", "A", "87", "XL", "94", "6", "33", "54.0", "88.1", "98.7", "", "", "", "", "96.7"]} -{"pcdb_id": 19103, "brand_name": "Alpha Innovation", "model_name": "E-Tec NXS", "model_qualifier": "20", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 24.0, "final_year_of_manufacture": null, "raw": ["019103", "020029", "0", "2023/Aug/11 12:18", "Immergas", "Alpha Innovation", "E-Tec NXS", "20", "3.033117", "2023", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24", "24", "A", "", "88.8", "79.8", "", "58.3", "", "2", "", "", "102", "1", "2", "12", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "1005", "", "", "", "", "94", "6", "32", "54.0", "88.1", "98.7", "", "", "", "", "96.7"]} -{"pcdb_id": 19104, "brand_name": "Alpha Innovation", "model_name": "E-Tec NXS", "model_qualifier": "30", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 28.0, "final_year_of_manufacture": null, "raw": ["019104", "020029", "0", "2023/Aug/11 12:24", "Immergas", "Alpha Innovation", "E-Tec NXS", "30", "3.033119", "2023", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "28", "28", "A", "", "88.8", "79.8", "", "58.3", "", "2", "", "", "102", "1", "2", "13", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "1005", "", "", "", "", "94", "6", "33", "54.0", "88.1", "98.7", "", "", "", "", "96.7"]} -{"pcdb_id": 19105, "brand_name": "Alpha Innovation", "model_name": "E-Tec NXS", "model_qualifier": "35", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 32.0, "final_year_of_manufacture": null, "raw": ["019105", "020029", "0", "2023/Aug/11 12:30", "Immergas", "Alpha Innovation", "E-Tec NXS", "35", "3.033120", "2023", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "32", "32", "A", "", "88.8", "79.8", "", "58.3", "", "2", "", "", "102", "1", "2", "20", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "1005", "", "", "", "", "94", "10", "45", "54.0", "88.1", "98.7", "", "", "", "", "96.7"]} -{"pcdb_id": 19106, "brand_name": "Alpha Innovation", "model_name": "E-Tec Plus NX", "model_qualifier": "28", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 82.7, "comparative_hot_water_efficiency_pct": 69.5, "output_kw_max": 24.0, "final_year_of_manufacture": null, "raw": ["019106", "020029", "0", "2023/Sep/11 16:46", "Immergas", "Alpha Innovation", "E-Tec Plus NX", "28", "3.033121", "2023", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "A", "", "88.8", "82.7", "", "69.5", "", "2", "", "", "104", "1", "2", "12", "2", "0", "", "", "", "0", "", "", "", "", "2", "7.576", "0.069", "0.0057", "1.41374", "13.894", "0.086", "0.0017", "0.93333", "0.00004", "0", "", "", "1005", "", "A", "87", "XL", "94", "6", "32", "54.0", "88.1", "98.7", "", "", "", "", "96.7"]} -{"pcdb_id": 19107, "brand_name": "Alpha Innovation", "model_name": "E-Tec Plus NX", "model_qualifier": "33", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 70.3, "output_kw_max": 28.0, "final_year_of_manufacture": null, "raw": ["019107", "020029", "0", "2023/Sep/11 16:54", "Immergas", "Alpha Innovation", "E-Tec Plus NX", "33", "3.033122", "2023", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28", "28", "A", "", "88.8", "79.9", "", "70.3", "", "2", "", "", "104", "1", "2", "13", "2", "0", "", "", "", "0", "", "", "", "", "2", "7.489", "0.077", "0.0021", "1.35105", "14.074", "0.1", "0.0035", "0.64996", "-0.00001", "0", "", "", "1005", "", "A", "87", "XL", "94", "6", "33", "54.0", "88.1", "98.7", "", "", "", "", "96.7"]} -{"pcdb_id": 19108, "brand_name": "Alpha Innovation", "model_name": "E-Tec Plus NX", "model_qualifier": "38", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 86.7, "comparative_hot_water_efficiency_pct": 70.2, "output_kw_max": 32.0, "final_year_of_manufacture": null, "raw": ["019108", "020029", "0", "2023/Sep/12 11:53", "Immergas", "Alpha Innovation", "E-Tec Plus NX", "38", "3.033123", "2023", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "32", "32", "A", "", "88.8", "86.7", "", "70.2", "", "2", "", "", "104", "1", "2", "20", "2", "0", "", "", "", "0", "", "", "", "", "1", "7.497", "0.129", "0.0053", "1.34033", "", "", "", "", "", "0", "", "", "1005", "", "A", "85", "XXL", "94", "10", "45", "54.0", "88.1", "98.7", "", "", "", "", "96.7"]} -{"pcdb_id": 19109, "brand_name": "Worcester", "model_name": "Greenstar 1000", "model_qualifier": "GR1000W 24 C NG", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 88.2, "comparative_hot_water_efficiency_pct": 75.2, "output_kw_max": 24.0, "final_year_of_manufacture": null, "raw": ["019109", "020051", "0", "2023/Oct/06 15:23", "Bosch Thermotechnology Ltd", "Worcester", "Greenstar 1000", "GR1000W 24 C NG", "47-800-38", "2023", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "A", "", "88.6", "88.2", "", "75.2", "", "2", "", "", "104", "1", "2", "42", "3", "0", "", "", "", "0", "", "", "", "", "2", "6.999", "0.114", "0.0028", "0.8686", "12.563", "0.141", "0.001", "0.85316", "0.00002", "0", "", "", "8305", "", "A", "84", "XL", "94", "11", "66", "51.0", "87.8", "98.5", "", "", "", "", "96.5"]} -{"pcdb_id": 19110, "brand_name": "Worcester", "model_name": "Greenstar 1000", "model_qualifier": "GR1000W 30 C NG", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 88.2, "comparative_hot_water_efficiency_pct": 75.7, "output_kw_max": 24.0, "final_year_of_manufacture": null, "raw": ["019110", "020051", "0", "2023/Oct/06 15:25", "Bosch Thermotechnology Ltd", "Worcester", "Greenstar 1000", "GR1000W 30 C NG", "47-800-39", "2023", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "A", "", "88.3", "88.2", "", "75.7", "", "2", "", "", "104", "1", "2", "40", "3", "0", "", "", "", "0", "", "", "", "", "2", "6.953", "0.113", "0.0022", "0.82108", "12.699", "0.137", "0.0009", "0.81257", "0.00001", "0", "", "", "8305", "", "A", "84", "XL", "94", "12", "67", "51.0", "87.6", "97.8", "", "", "", "", "95.9"]} -{"pcdb_id": 19111, "brand_name": "Morco", "model_name": "IV", "model_qualifier": "GB24 PROPANE", "winter_efficiency_pct": 90.1, "summer_efficiency_pct": 90.3, "comparative_hot_water_efficiency_pct": 71.7, "output_kw_max": 24.2, "final_year_of_manufacture": null, "raw": ["019111", "020099", "0", "2023/Oct/20 15:38", "Ideal Boilers", "Morco", "IV", "GB24 PROPANE", "236485", "2023", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "A", "", "90.1", "90.3", "", "71.7", "", "2", "1", "", "104", "1", "2", "29", "3", "0", "", "", "", "0", "", "", "", "", "2", "7.507", "0.146", "0.0045", "1.40589", "13.369", "0.166", "0.002", "1.34178", "0.00003", "0", "", "", "0005", "", "A", "82", "L", "94", "22", "83", "50.0", "92.0", "100.8", "", "", "", "", "99.1"]} -{"pcdb_id": 19112, "brand_name": "Morco", "model_name": "IV", "model_qualifier": "GB30 PROPANE", "winter_efficiency_pct": 90.1, "summer_efficiency_pct": 90.3, "comparative_hot_water_efficiency_pct": 68.7, "output_kw_max": 24.2, "final_year_of_manufacture": null, "raw": ["019112", "020099", "0", "2023/Oct/20 15:53", "Ideal Boilers", "Morco", "IV", "GB30 PROPANE", "236486", "2023", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "A", "", "90.1", "90.3", "", "68.7", "", "2", "1", "", "104", "1", "2", "29", "3", "0", "", "", "", "0", "", "", "", "", "2", "7.841", "0.144", "0.0065", "1.71798", "13.663", "0.17", "0.002", "1.65101", "0.00005", "0", "", "", "0005", "", "A", "80", "L", "94", "14", "65", "50.0", "92.0", "100.8", "", "", "", "", "99.1"]} -{"pcdb_id": 19113, "brand_name": "Morco", "model_name": "IV", "model_qualifier": "GB24 NG", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 70.0, "output_kw_max": 24.3, "final_year_of_manufacture": null, "raw": ["019113", "020099", "0", "2023/Oct/20 15:04", "Ideal Boilers", "Morco", "IV", "GB24 NG", "236487", "2023", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.3", "24.3", "A", "", "89.0", "87.3", "", "70.0", "", "2", "", "", "104", "1", "2", "44", "3", "0", "", "", "", "0", "", "", "", "", "1", "7.526", "0.12", "0.0027", "1.43483", "", "", "", "", "", "0", "", "", "0005", "", "A", "77", "M", "94", "12", "70", "50.0", "90.0", "98.6", "", "", "", "", "96.9"]} -{"pcdb_id": 19114, "brand_name": "Morco", "model_name": "IV", "model_qualifier": "GB30 NG", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 69.5, "output_kw_max": 24.3, "final_year_of_manufacture": null, "raw": ["019114", "020099", "0", "2023/Oct/20 15:40", "Ideal Boilers", "Morco", "IV", "GB30 NG", "236488", "2023", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.3", "24.3", "A", "", "89.0", "87.3", "", "69.5", "", "2", "", "", "104", "1", "2", "28", "3", "0", "", "", "", "0", "", "", "", "", "1", "7.576", "0.119", "0.0027", "1.48359", "", "", "", "", "", "0", "", "", "0005", "", "A", "76", "M", "94", "11", "58", "50.0", "90.0", "98.6", "", "", "", "", "96.9"]} -{"pcdb_id": 19115, "brand_name": "Baxi", "model_name": "ASSURE 524 SYSTEM 2", "model_qualifier": "", "winter_efficiency_pct": 89.9, "summer_efficiency_pct": 80.9, "comparative_hot_water_efficiency_pct": 59.1, "output_kw_max": 27.4, "final_year_of_manufacture": null, "raw": ["019115", "020101", "0", "2023/Oct/25 16:32", "Baxi Heating UK Ltd", "Baxi", "ASSURE 524 SYSTEM 2", "", "41-844-06", "2023", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "27.4", "27.4", "A", "", "89.9", "80.9", "", "59.1", "", "2", "1", "", "102", "1", "2", "46", "4", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "94", "8", "68", "40.0", "90.2", "101.2", "", "", "", "", "99.1"]} -{"pcdb_id": 19116, "brand_name": "Baxi", "model_name": "ASSURE 518 SYSTEM 2", "model_qualifier": "", "winter_efficiency_pct": 89.9, "summer_efficiency_pct": 80.9, "comparative_hot_water_efficiency_pct": 59.1, "output_kw_max": 20.7, "final_year_of_manufacture": null, "raw": ["019116", "020101", "0", "2023/Oct/25 16:33", "Baxi Heating UK Ltd", "Baxi", "ASSURE 518 SYSTEM 2", "", "41-844-05", "2023", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "20.7", "20.7", "A", "", "89.9", "80.9", "", "59.1", "", "2", "1", "", "102", "1", "2", "26", "4", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "94", "8", "56", "40.0", "90.2", "101.2", "", "", "", "", "99.1"]} -{"pcdb_id": 19117, "brand_name": "Baxi", "model_name": "ASSURE 515 SYSTEM 2", "model_qualifier": "", "winter_efficiency_pct": 89.9, "summer_efficiency_pct": 80.9, "comparative_hot_water_efficiency_pct": 59.1, "output_kw_max": 17.2, "final_year_of_manufacture": null, "raw": ["019117", "020101", "0", "2023/Oct/25 16:33", "Baxi Heating UK Ltd", "Baxi", "ASSURE 515 SYSTEM 2", "", "41-844-04", "2023", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "17.2", "17.2", "A", "", "89.9", "80.9", "", "59.1", "", "2", "1", "", "102", "1", "2", "16", "4", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "94", "8", "51", "40.0", "90.2", "101.2", "", "", "", "", "99.1"]} -{"pcdb_id": 19118, "brand_name": "Baxi", "model_name": "ASSURE 524 COMBI 2", "model_qualifier": "", "winter_efficiency_pct": 89.9, "summer_efficiency_pct": 88.7, "comparative_hot_water_efficiency_pct": 82.2, "output_kw_max": 22.9, "final_year_of_manufacture": null, "raw": ["019118", "020101", "0", "2023/Oct/25 16:35", "Baxi Heating UK Ltd", "Baxi", "ASSURE 524 COMBI 2", "", "47-077-59", "2023", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "22.9", "22.9", "A", "", "89.9", "88.7", "", "82.2", "", "2", "1", "", "104", "1", "2", "46", "4", "0", "", "", "", "0", "", "", "", "", "1", "6.548", "0.074", "0.0029", "0.44307", "", "", "", "", "", "0", "", "", "0405", "", "A", "93", "XL", "94", "8", "68", "40.0", "90.2", "101.2", "", "", "", "", "99.1"]} -{"pcdb_id": 19119, "brand_name": "Baxi", "model_name": "ASSURE 530 COMBI 2", "model_qualifier": "", "winter_efficiency_pct": 89.9, "summer_efficiency_pct": 88.6, "comparative_hot_water_efficiency_pct": 83.2, "output_kw_max": 28.6, "final_year_of_manufacture": null, "raw": ["019119", "020101", "0", "2023/Oct/25 16:35", "Baxi Heating UK Ltd", "Baxi", "ASSURE 530 COMBI 2", "", "47-077-60", "2023", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "28.6", "28.6", "A", "", "89.9", "88.6", "", "83.2", "", "2", "1", "", "104", "1", "2", "61", "4", "0", "", "", "", "0", "", "", "", "", "1", "6.474", "0.071", "0.0021", "0.37197", "", "", "", "", "", "0", "", "", "0405", "", "A", "93", "XL", "94", "9", "79", "40.0", "90.0", "101.1", "", "", "", "", "99.0"]} -{"pcdb_id": 19120, "brand_name": "Baxi", "model_name": "ASSURE 536 COMBI 2", "model_qualifier": "", "winter_efficiency_pct": 89.8, "summer_efficiency_pct": 88.6, "comparative_hot_water_efficiency_pct": 83.2, "output_kw_max": 28.6, "final_year_of_manufacture": null, "raw": ["019120", "020101", "0", "2023/Oct/25 16:35", "Baxi Heating UK Ltd", "Baxi", "ASSURE 536 COMBI 2", "", "47-077-61", "2023", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "28.6", "28.6", "A", "", "89.8", "88.6", "", "83.2", "", "2", "1", "", "104", "1", "2", "71", "4", "0", "", "", "", "0", "", "", "", "", "1", "6.47", "0.071", "0.0021", "0.37024", "", "", "", "", "", "0", "", "", "0405", "", "A", "93", "XL", "94", "9", "85", "40.0", "90.1", "101.0", "", "", "", "", "99.0"]} -{"pcdb_id": 19121, "brand_name": "Viessmann", "model_name": "VITODENS 050-W", "model_qualifier": "B0KA-35", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 84.4, "comparative_hot_water_efficiency_pct": 69.4, "output_kw_max": 29.9, "final_year_of_manufacture": null, "raw": ["019121", "020094", "0", "2023/Nov/15 13:27", "Viessmann Ltd", "Viessmann", "VITODENS 050-W", "B0KA-35", "", "2022", "current", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "29.9", "29.9", "A", "", "88.3", "84.4", "", "69.4", "", "2", "", "", "104", "1", "2", "22.1", "4.1", "0", "", "", "", "0", "", "", "", "", "2", "7.592", "0.207", "0.004", "1.41177", "13.791", "0.233", "0.0017", "1.10061", "0.00002", "0", "", "", "00020005", "", "A", "81", "XL", "93", "14.7", "69", "56.3", "87.1", "97.8", "", "", "", "", "95.8"]} -{"pcdb_id": 19122, "brand_name": "Viessmann", "model_name": "VITODENS 050-W", "model_qualifier": "B0KA-35", "winter_efficiency_pct": 89.5, "summer_efficiency_pct": 87.6, "comparative_hot_water_efficiency_pct": 66.5, "output_kw_max": 30.2, "final_year_of_manufacture": null, "raw": ["019122", "020094", "0", "2023/Nov/15 13:28", "Viessmann Ltd", "Viessmann", "VITODENS 050-W", "B0KA-35", "", "2022", "current", "2", "2", "1", "2", "0", "", "", "2", "3", "2", "30.2", "30.2", "A", "", "89.5", "87.6", "", "66.5", "", "2", "0", "2", "104", "1", "2", "22.1", "4.1", "0", "", "", "", "0", "", "", "", "", "2", "8.093", "0.204", "0.0022", "1.91888", "14.203", "0.225", "0.001", "1.68297", "0.00001", "0", "", "", "00020005", "", "A", "81", "XL", "93", "14.7", "69", "56.3", "89.6", "97.7", "", "", "", "", "96.2"]} -{"pcdb_id": 19123, "brand_name": "Alpha Innovation", "model_name": "E-Tec 33 HB", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 88.2, "comparative_hot_water_efficiency_pct": 75.8, "output_kw_max": 32.0, "final_year_of_manufacture": null, "raw": ["019123", "020029", "0", "2023/Nov/15 11:26", "Immergas", "Alpha Innovation", "E-Tec 33 HB", "", "3.033301", "2023", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "4.9", "32", "A", "", "88.4", "88.2", "", "75.8", "", "2", "", "", "104", "1", "2", "12", "2", "0", "", "", "", "0", "", "", "", "", "2", "6.949", "0.115", "0.006", "0.81076", "12.677", "0.124", "0.004", "0.78634", "0.00002", "0", "", "0", "0025", "", "A", "87", "XL", "93", "6", "32", "57.0", "88.2", "97.7", "", "", "", "", "95.9"]} -{"pcdb_id": 19124, "brand_name": "Vokera By Riello", "model_name": "UNICA MAX", "model_qualifier": "30S", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 31.23, "final_year_of_manufacture": null, "raw": ["019124", "020088", "0", "2023/Dec/18 11:47", "Vokera Ltd.", "Vokera By Riello", "UNICA MAX", "30S", "41-364-14", "2021", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "31.23", "31.23", "A", "", "88.7", "79.7", "", "58.2", "", "2", "", "", "102", "1", "2", "49", "3", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "94", "13", "75", "26.0", "87.9", "98.7", "", "", "", "", "96.6"]} -{"pcdb_id": 19125, "brand_name": "Vokera By Riello", "model_name": "UNICA MAX", "model_qualifier": "30C", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 88.2, "comparative_hot_water_efficiency_pct": 77.0, "output_kw_max": 24.43, "final_year_of_manufacture": null, "raw": ["019125", "020088", "0", "2023/Dec/18 11:06", "Vokera Ltd.", "Vokera By Riello", "UNICA MAX", "30C", "47-364-75", "2022", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.43", "24.43", "A", "", "88.7", "88.2", "", "77.0", "", "2", "", "", "104", "1", "2", "32", "3", "0", "", "", "", "0", "", "", "", "", "2", "6.835", "0.142", "0.0029", "0.71465", "12.377", "0.113", "0.0003", "0.6951", "0.00003", "0", "", "", "0025", "", "A", "85", "XL", "94", "13", "65", "26.0", "88.0", "98.7", "", "", "", "", "96.6"]} -{"pcdb_id": 19126, "brand_name": "Vaillant", "model_name": "ecoTEC plus 610", "model_qualifier": "VU 10CS/1-5 (N-GB)", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 10.0, "final_year_of_manufacture": null, "raw": ["019126", "020033", "0", "2023/Dec/07 11:40", "Vaillant Group UK Ltd", "Vaillant", "ecoTEC plus 610", "VU 10CS/1-5 (N-GB)", "41-694-45", "2023", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "10", "10", "A", "", "88.2", "79.2", "", "57.8", "", "2", "", "", "102", "1", "2", "17", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "00C5", "", "", "", "", "92", "13", "50", "42.0", "87.5", "97.5", "", "", "", "", "95.6"]} -{"pcdb_id": 19127, "brand_name": "Vaillant", "model_name": "ecoTEC plus 615", "model_qualifier": "VU 15CS/1-5 (N-GB)", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 15.0, "final_year_of_manufacture": null, "raw": ["019127", "020033", "0", "2023/Dec/07 11:44", "Vaillant Group UK Ltd", "Vaillant", "ecoTEC plus 615", "VU 15CS/1-5 (N-GB)", "41-694-46", "2023", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "15", "15", "A", "", "88.3", "79.3", "", "57.9", "", "2", "", "", "102", "1", "2", "22", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "00C5", "", "", "", "", "93", "13", "53", "42.0", "87.4", "97.8", "", "", "", "", "95.9"]} -{"pcdb_id": 19128, "brand_name": "Vaillant", "model_name": "ecoTEC plus 625", "model_qualifier": "VU 25CS/1-5 (N-GB)", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 25.0, "final_year_of_manufacture": null, "raw": ["019128", "020033", "0", "2023/Dec/07 11:54", "Vaillant Group UK Ltd", "Vaillant", "ecoTEC plus 625", "VU 25CS/1-5 (N-GB)", "41-694-48", "2023", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "25", "25", "A", "", "88.7", "79.7", "", "58.2", "", "2", "", "", "102", "1", "2", "28", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "00C5", "", "", "", "", "94", "15", "61", "48.0", "88.1", "98.6", "", "", "", "", "96.6"]} -{"pcdb_id": 19129, "brand_name": "Vaillant", "model_name": "ecoTEC plus 630", "model_qualifier": "VU 30CS/1-5 (N-GB)", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 30.0, "final_year_of_manufacture": null, "raw": ["019129", "020033", "0", "2023/Dec/07 11:59", "Vaillant Group UK Ltd", "Vaillant", "ecoTEC plus 630", "VU 30CS/1-5 (N-GB)", "41-694-49", "2023", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "30", "30", "A", "", "88.6", "79.6", "", "58.1", "", "2", "", "", "102", "1", "2", "36", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "00C5", "", "", "", "", "94", "16", "68", "45.0", "88.0", "98.3", "", "", "", "", "96.3"]} -{"pcdb_id": 19130, "brand_name": "Vaillant", "model_name": "ecoTEC plus 635", "model_qualifier": "VU 35CS/1-5 (N-GB)", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 35.0, "final_year_of_manufacture": null, "raw": ["019130", "020033", "0", "2023/Dec/07 12:04", "Vaillant Group UK Ltd", "Vaillant", "ecoTEC plus 635", "VU 35CS/1-5 (N-GB)", "41-694-50", "2023", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "35", "35", "A", "", "88.7", "79.7", "", "58.2", "", "2", "", "", "102", "1", "2", "51", "1", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "00C5", "", "", "", "", "94", "16", "70", "52.0", "87.9", "98.6", "", "", "", "", "96.5"]} -{"pcdb_id": 19131, "brand_name": "Vaillant", "model_name": "ecoTEC plus 826", "model_qualifier": "VUW 20/26CS/1-5 (N-GB)", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 81.8, "comparative_hot_water_efficiency_pct": 79.7, "output_kw_max": 20.0, "final_year_of_manufacture": null, "raw": ["019131", "020033", "0", "2023/Dec/07 12:09", "Vaillant Group UK Ltd", "Vaillant", "ecoTEC plus 826", "VUW 20/26CS/1-5 (N-GB)", "47-044-92", "2023", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "20", "20", "A", "", "88.4", "81.8", "", "79.7", "", "2", "", "", "104", "1", "2", "31", "2", "0", "", "", "", "0", "", "", "", "", "2", "6.604", "0.074", "0.0134", "0.4205", "12.977", "0.088", "0.0044", "0.0", "0.00009", "0", "", "", "00C5", "", "A", "87", "XL", "93", "14", "60", "47.0", "87.6", "98.0", "", "", "", "", "96.0"]} -{"pcdb_id": 19132, "brand_name": "Vaillant", "model_name": "ecoTEC plus 832", "model_qualifier": "VUW 25/32CS/1-5 (N-GB)", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 81.2, "comparative_hot_water_efficiency_pct": 68.9, "output_kw_max": 25.0, "final_year_of_manufacture": null, "raw": ["019132", "020033", "0", "2023/Dec/07 12:14", "Vaillant Group UK Ltd", "Vaillant", "ecoTEC plus 832", "VUW 25/32CS/1-5 (N-GB)", "47-044-93", "2023", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "25", "25", "A", "", "88.7", "81.2", "", "68.9", "", "2", "", "", "104", "1", "2", "28", "2", "0", "", "", "", "0", "", "", "", "", "2", "7.649", "0.072", "0.0076", "1.4729", "14.057", "0.085", "0.0009", "0.8671", "0.00007", "0", "", "", "00C5", "", "A", "84", "XL", "94", "15", "61", "49.0", "88.1", "98.6", "", "", "", "", "96.6"]} -{"pcdb_id": 19133, "brand_name": "Vaillant", "model_name": "ecoTEC plus 836", "model_qualifier": "VUW 30/36CS/1-5 (N-GB)", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 80.7, "comparative_hot_water_efficiency_pct": 78.2, "output_kw_max": 30.0, "final_year_of_manufacture": null, "raw": ["019133", "020033", "0", "2023/Dec/07 12:18", "Vaillant Group UK Ltd", "Vaillant", "ecoTEC plus 836", "VUW 30/36CS/1-5 (N-GB)", "47-044-94", "2023", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "30", "30", "A", "", "88.6", "80.7", "", "78.2", "", "2", "", "", "104", "1", "2", "36", "2", "0", "", "", "", "0", "", "", "", "", "2", "6.735", "0.08", "0.0102", "0.57567", "13.171", "0.094", "0.0012", "0.0069", "0.00009", "0", "", "", "00C5", "", "A", "87", "XL", "94", "16", "68", "49.0", "88.0", "98.3", "", "", "", "", "96.3"]} -{"pcdb_id": 19134, "brand_name": "Vaillant", "model_name": "ecoTEC plus 840", "model_qualifier": "VUW 30/40CS/1-5 (N-GB)", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 78.0, "comparative_hot_water_efficiency_pct": 79.3, "output_kw_max": 30.0, "final_year_of_manufacture": null, "raw": ["019134", "020033", "0", "2023/Dec/07 12:21", "Vaillant Group UK Ltd", "Vaillant", "ecoTEC plus 840", "VUW 30/40CS/1-5 (N-GB)", "47-044-95", "2023", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "30", "30", "A", "", "88.6", "78.0", "", "79.3", "", "2", "", "", "104", "1", "2", "39", "1", "0", "", "", "", "0", "", "", "", "", "2", "6.643", "0.072", "0.0057", "0.50928", "13.327", "0.127", "0.0009", "0.0", "0.00005", "0", "", "", "00C5", "", "A", "89", "XL", "94", "15", "61", "56.0", "87.8", "98.4", "", "", "", "", "96.4"]} -{"pcdb_id": 19135, "brand_name": "Vaillant", "model_name": "ecoTEC plus 620", "model_qualifier": "VU 20CS/1-5 (N-GB)", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 20.0, "final_year_of_manufacture": null, "raw": ["019135", "020033", "0", "2023/Dec/07 11:50", "Vaillant Group UK Ltd", "Vaillant", "ecoTEC plus 620", "VU 20CS/1-5 (N-GB)", "41-694-47", "2023", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "20", "20", "A", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "31", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "00C5", "", "", "", "", "93", "14", "60", "47.0", "87.6", "98.0", "", "", "", "", "96.0"]} -{"pcdb_id": 19136, "brand_name": "Navien", "model_name": "NCB300", "model_qualifier": "NCB300-28K", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 88.2, "comparative_hot_water_efficiency_pct": 70.4, "output_kw_max": 24.0, "final_year_of_manufacture": null, "raw": ["019136", "020178", "0", "2024/Jan/26 09:28", "Navien UK", "Navien", "NCB300", "NCB300-28K", "", "2022", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "A", "", "88.1", "88.2", "", "70.4", "", "2", "", "", "104", "1", "2", "39", "3", "0", "", "", "", "0", "", "", "", "", "2", "7.476", "0.125", "0.0245", "1.21005", "13.146", "0.142", "0.002", "1.18378", "0.00023", "0", "", "", "0005", "", "A", "84", "XL", "93", "17", "78", "78.0", "88.2", "96.9", "", "", "", "", "95.3"]} -{"pcdb_id": 19137, "brand_name": "Vokera By Riello", "model_name": "VIBE MAX", "model_qualifier": "26C", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 87.6, "comparative_hot_water_efficiency_pct": 77.2, "output_kw_max": 19.38, "final_year_of_manufacture": null, "raw": ["019137", "020088", "0", "2024/Feb/02 10:25", "Vokera Ltd.", "Vokera By Riello", "VIBE MAX", "26C", "47-364-69", "2022", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "19.38", "19.38", "A", "", "88.5", "87.6", "", "77.2", "", "2", "", "", "104", "1", "2", "32", "3", "0", "", "", "", "0", "", "", "", "", "2", "6.824", "0.102", "0.003", "0.68563", "12.795", "0.107", "0.0011", "0.63873", "0.00002", "0", "", "", "0025", "", "A", "84", "XL", "93", "12", "63", "30.0", "87.3", "98.3", "", "", "", "", "96.2"]} -{"pcdb_id": 19138, "brand_name": "Vokera By Riello", "model_name": "VIBE MAX", "model_qualifier": "30C", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 85.1, "comparative_hot_water_efficiency_pct": 77.5, "output_kw_max": 24.38, "final_year_of_manufacture": null, "raw": ["019138", "020088", "0", "2024/Feb/02 10:38", "Vokera Ltd.", "Vokera By Riello", "VIBE MAX", "30C", "47-364-70", "2022", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.38", "24.38", "A", "", "88.5", "85.1", "", "77.5", "", "2", "", "", "104", "1", "2", "38", "3", "0", "", "", "", "0", "", "", "", "", "2", "6.798", "0.102", "0.001", "0.6857", "12.963", "0.118", "0.0016", "0.44078", "-0.00001", "0", "", "", "0025", "", "A", "84", "XL", "93", "12", "66", "32.0", "87.8", "98.0", "", "", "", "", "96.1"]} -{"pcdb_id": 19139, "brand_name": "Vokera By Riello", "model_name": "VIBE MAX", "model_qualifier": "20S", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 19.38, "final_year_of_manufacture": null, "raw": ["019139", "020088", "0", "2024/Feb/02 11:05", "Vokera Ltd.", "Vokera By Riello", "VIBE MAX", "20S", "41-364-19", "2022", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "19.38", "19.38", "A", "", "88.5", "79.5", "", "58.1", "", "2", "", "", "102", "1", "2", "32", "3", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "93", "12", "63", "30.0", "87.3", "98.3", "", "", "", "", "96.2"]} -{"pcdb_id": 19140, "brand_name": "Vokera By Riello", "model_name": "VIBE MAX", "model_qualifier": "25S", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 24.38, "final_year_of_manufacture": null, "raw": ["019140", "020088", "0", "2024/Feb/02 11:06", "Vokera Ltd.", "Vokera By Riello", "VIBE MAX", "25S", "41-364-20", "2022", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24.38", "24.38", "A", "", "88.5", "79.5", "", "58.0", "", "2", "", "", "102", "1", "2", "38", "3", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "93", "12", "66", "32.0", "87.8", "98.0", "", "", "", "", "96.1"]} -{"pcdb_id": 19141, "brand_name": "Vokera By Riello", "model_name": "EXCEL-i", "model_qualifier": "25C", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 87.6, "comparative_hot_water_efficiency_pct": 77.2, "output_kw_max": 19.38, "final_year_of_manufacture": null, "raw": ["019141", "020088", "0", "2024/Feb/02 11:15", "Vokera Ltd.", "Vokera By Riello", "EXCEL-i", "25C", "47-364-65", "2021", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "19.38", "19.38", "A", "", "88.5", "87.6", "", "77.2", "", "2", "", "", "104", "1", "2", "32", "3", "0", "", "", "", "0", "", "", "", "", "2", "6.824", "0.102", "0.003", "0.68563", "12.795", "0.107", "0.0011", "0.63873", "0.00002", "0", "", "", "0025", "", "A", "84", "XL", "93", "12", "63", "30.0", "87.3", "98.3", "", "", "", "", "96.2"]} -{"pcdb_id": 19142, "brand_name": "Vokera By Riello", "model_name": "EXCEL-i", "model_qualifier": "30C", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 85.1, "comparative_hot_water_efficiency_pct": 77.5, "output_kw_max": 24.38, "final_year_of_manufacture": null, "raw": ["019142", "020088", "0", "2024/Feb/02 11:26", "Vokera Ltd.", "Vokera By Riello", "EXCEL-i", "30C", "47-364-66", "2022", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.38", "24.38", "A", "", "88.5", "85.1", "", "77.5", "", "2", "", "", "104", "1", "2", "38", "3", "0", "", "", "", "0", "", "", "", "", "2", "6.798", "0.102", "0.001", "0.6857", "12.963", "0.118", "0.0016", "0.44078", "-0.00001", "0", "", "", "0025", "", "A", "84", "XL", "93", "12", "66", "32.0", "87.8", "98.0", "", "", "", "", "96.1"]} -{"pcdb_id": 19143, "brand_name": "Vokera By Riello", "model_name": "EASI-HEAT i", "model_qualifier": "20S", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 19.38, "final_year_of_manufacture": null, "raw": ["019143", "020088", "0", "2024/Feb/02 11:35", "Vokera Ltd.", "Vokera By Riello", "EASI-HEAT i", "20S", "47-364-17", "2022", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "19.38", "19.38", "A", "", "88.5", "79.5", "", "58.1", "", "2", "", "", "102", "1", "2", "32", "3", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "93", "12", "63", "30.0", "87.3", "98.3", "", "", "", "", "96.2"]} -{"pcdb_id": 19144, "brand_name": "Navien", "model_name": "NCB300", "model_qualifier": "NCB300-28K", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 90.3, "comparative_hot_water_efficiency_pct": 73.3, "output_kw_max": 24.0, "final_year_of_manufacture": null, "raw": ["019144", "020178", "0", "2024/Jan/26 09:37", "Navien UK", "Navien", "NCB300", "NCB300-28K", "", "2022", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "A", "", "88.7", "90.3", "", "73.3", "", "2", "0", "2", "104", "1", "2", "39", "3", "0", "", "", "", "0", "", "", "", "", "2", "7.346", "0.111", "0.0065", "1.18048", "13.261", "0.135", "0.0025", "1.17539", "0.00004", "0", "", "", "0005", "", "A", "84", "XL", "93", "17", "78", "78.0", "89.8", "95.7", "", "", "", "", "94.6"]} -{"pcdb_id": 19145, "brand_name": "Navien", "model_name": "NCB300", "model_qualifier": "NCB300-37K", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 87.2, "comparative_hot_water_efficiency_pct": 71.5, "output_kw_max": 26.0, "final_year_of_manufacture": null, "raw": ["019145", "020178", "0", "2024/Jan/26 09:51", "Navien UK", "Navien", "NCB300", "NCB300-37K", "", "2022", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "26", "26", "A", "", "88.3", "87.2", "", "71.5", "", "2", "", "", "104", "1", "2", "34", "3", "0", "", "", "", "0", "", "", "", "", "2", "7.363", "0.116", "0.006", "1.21901", "13.358", "0.134", "0.0025", "1.10586", "0.00004", "0", "", "", "0005", "", "A", "84", "XL", "93", "16", "72", "78.0", "88.6", "97.4", "", "", "", "", "95.7"]} -{"pcdb_id": 19146, "brand_name": "Navien", "model_name": "NCB300", "model_qualifier": "NCB300-41K", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 88.2, "comparative_hot_water_efficiency_pct": 70.0, "output_kw_max": 26.0, "final_year_of_manufacture": null, "raw": ["019146", "020178", "0", "2024/Jan/26 10:03", "Navien UK", "Navien", "NCB300", "NCB300-41K", "", "2022", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "26", "26", "A", "", "88.3", "88.2", "", "70.0", "", "2", "", "", "104", "1", "2", "34", "3", "0", "", "", "", "0", "", "", "", "", "2", "7.528", "0.123", "0.012", "1.34303", "13.168", "0.138", "0.0015", "1.30673", "0.00011", "0", "", "", "0005", "", "A", "83", "XL", "93", "16", "72", "78.0", "88.6", "97.4", "", "", "", "", "95.7"]} -{"pcdb_id": 19147, "brand_name": "Navien", "model_name": "NCB300", "model_qualifier": "NCB300-37K", "winter_efficiency_pct": 89.8, "summer_efficiency_pct": 90.3, "comparative_hot_water_efficiency_pct": 72.1, "output_kw_max": 26.0, "final_year_of_manufacture": null, "raw": ["019147", "020178", "0", "2024/Jan/26 10:12", "Navien UK", "Navien", "NCB300", "NCB300-37K", "", "2022", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "26", "26", "A", "", "89.8", "90.3", "", "72.1", "", "2", "0", "2", "104", "1", "2", "34", "3", "0", "", "", "", "0", "", "", "", "", "2", "7.468", "0.123", "0.006", "1.3349", "13.329", "0.139", "0.002", "1.29553", "0.00004", "0", "", "", "0005", "", "A", "84", "XL", "93", "16", "72", "78.0", "91.1", "97.8", "", "", "", "", "96.5"]} -{"pcdb_id": 19148, "brand_name": "Navien", "model_name": "NCB300", "model_qualifier": "NCB300-41K", "winter_efficiency_pct": 89.8, "summer_efficiency_pct": 90.3, "comparative_hot_water_efficiency_pct": 73.3, "output_kw_max": 26.0, "final_year_of_manufacture": null, "raw": ["019148", "020178", "0", "2024/Jan/26 10:34", "Navien UK", "Navien", "NCB300", "NCB300-41K", "", "2022", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "26", "26", "A", "", "89.8", "90.3", "", "73.3", "", "2", "0", "2", "104", "1", "2", "34", "3", "0", "", "", "", "0", "", "", "", "", "2", "7.34", "0.11", "0.0055", "1.21416", "13.254", "0.127", "0.0025", "1.17547", "0.00003", "0", "", "", "0005", "", "A", "83", "XL", "93", "16", "72", "78.0", "91.1", "97.8", "", "", "", "", "96.5"]} -{"pcdb_id": 19149, "brand_name": "Navien", "model_name": "NCB700", "model_qualifier": "NCB700-2S+/42K", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 88.2, "comparative_hot_water_efficiency_pct": 75.5, "output_kw_max": 34.0, "final_year_of_manufacture": null, "raw": ["019149", "020178", "0", "2024/Jan/26 10:54", "Navien UK", "Navien", "NCB700", "NCB700-2S+/42K", "", "2022", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "34", "34", "A", "", "88.7", "88.2", "", "75.5", "", "2", "", "", "104", "1", "2", "51", "3", "0", "", "", "", "0", "", "", "", "", "2", "6.974", "0.124", "0.005", "0.84296", "12.614", "0.138", "0.0015", "0.81617", "0.00004", "0", "", "", "0005", "", "A", "86", "XXL", "94", "25", "102", "89.0", "88.3", "98.6", "", "", "", "", "96.6"]} -{"pcdb_id": 19150, "brand_name": "Navien", "model_name": "NCB700", "model_qualifier": "NCB700-2S+/42k", "winter_efficiency_pct": 90.2, "summer_efficiency_pct": 90.3, "comparative_hot_water_efficiency_pct": 75.4, "output_kw_max": 34.0, "final_year_of_manufacture": null, "raw": ["019150", "020178", "0", "2024/Jan/26 11:05", "Navien UK", "Navien", "NCB700", "NCB700-2S+/42k", "", "2022", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "34", "34", "A", "", "90.2", "90.3", "", "75.4", "", "2", "0", "2", "104", "1", "2", "51", "3", "0", "", "", "", "0", "", "", "", "", "2", "7.138", "0.135", "0.005", "1.01959", "12.989", "0.152", "0.0025", "0.9843", "0.00003", "0", "", "", "0005", "", "A", "86", "XXL", "94", "25", "102", "89.0", "91.0", "98.9", "", "", "", "", "97.4"]} -{"pcdb_id": 19151, "brand_name": "Navien", "model_name": "NCB700", "model_qualifier": "NCB700-3S/54K", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 88.2, "comparative_hot_water_efficiency_pct": 74.4, "output_kw_max": 34.0, "final_year_of_manufacture": null, "raw": ["019151", "020178", "0", "2024/Jan/26 11:16", "Navien UK", "Navien", "NCB700", "NCB700-3S/54K", "", "2022", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "34", "34", "A", "", "89.1", "88.2", "", "74.4", "", "2", "", "", "104", "1", "2", "43", "3", "0", "", "", "", "0", "", "", "", "", "2", "7.074", "0.131", "0.0045", "0.9607", "12.75", "0.148", "0.002", "0.91503", "0.00003", "0", "", "", "0005", "", "A", "86", "XXL", "94", "20", "86", "80.0", "89.0", "99.1", "", "", "", "", "97.2"]} -{"pcdb_id": 19152, "brand_name": "Navien", "model_name": "NCB700", "model_qualifier": "NCB700-3S/54K", "winter_efficiency_pct": 90.2, "summer_efficiency_pct": 90.3, "comparative_hot_water_efficiency_pct": 71.5, "output_kw_max": 34.0, "final_year_of_manufacture": null, "raw": ["019152", "020178", "0", "2024/Jan/26 11:26", "Navien UK", "Navien", "NCB700", "NCB700-3S/54K", "", "2022", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "34", "34", "A", "", "90.2", "90.3", "", "71.5", "", "2", "0", "2", "104", "1", "2", "43", "3", "0", "", "", "", "0", "", "", "", "", "2", "7.528", "0.123", "0.012", "1.34795", "13.168", "0.138", "0.0015", "1.31812", "0.00011", "0", "", "", "0005", "", "A", "86", "XXL", "94", "20", "86", "80.0", "90.7", "99.2", "", "", "", "", "97.6"]} -{"pcdb_id": 19153, "brand_name": "Navien", "model_name": "NCB500", "model_qualifier": "NCB500-2S/37K", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 88.2, "comparative_hot_water_efficiency_pct": 69.9, "output_kw_max": 26.0, "final_year_of_manufacture": null, "raw": ["019153", "020178", "0", "2024/Jan/26 11:41", "Navien UK", "Navien", "NCB500", "NCB500-2S/37K", "", "2022", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "26", "26", "A", "", "88.3", "88.2", "", "69.9", "", "2", "", "", "104", "1", "2", "34", "3", "0", "", "", "", "0", "", "", "", "", "2", "7.529", "0.161", "0.005", "1.38491", "13.408", "0.144", "0.002", "1.3486", "0.00003", "0", "", "", "0005", "", "A", "83", "XL", "93", "16", "72", "78.0", "88.6", "97.4", "", "", "", "", "95.7"]} -{"pcdb_id": 19154, "brand_name": "Navien", "model_name": "NCB500", "model_qualifier": "NCB500-2S/37K", "winter_efficiency_pct": 89.8, "summer_efficiency_pct": 88.5, "comparative_hot_water_efficiency_pct": 71.3, "output_kw_max": 26.0, "final_year_of_manufacture": null, "raw": ["019154", "020178", "0", "2024/Jan/26 11:51", "Navien UK", "Navien", "NCB500", "NCB500-2S/37K", "", "2022", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "26", "26", "A", "", "89.8", "88.5", "", "71.3", "", "2", "0", "2", "104", "1", "2", "34", "3", "0", "", "", "", "0", "", "", "", "", "2", "7.553", "0.127", "0.0025", "1.43748", "13.599", "0.142", "0.0015", "1.25691", "0.00001", "0", "", "", "0005", "", "A", "83", "XL", "93", "16", "72", "78.0", "91.1", "97.8", "", "", "", "", "96.5"]} -{"pcdb_id": 19155, "brand_name": "Navien", "model_name": "NCB500", "model_qualifier": "NCB500-2S+/41K", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 87.4, "comparative_hot_water_efficiency_pct": 69.7, "output_kw_max": 26.0, "final_year_of_manufacture": null, "raw": ["019155", "020178", "0", "2024/Jan/26 12:00", "Navien UK", "Navien", "NCB500", "NCB500-2S+/41K", "", "2022", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "26", "26", "A", "", "88.3", "87.4", "", "69.7", "", "2", "", "", "104", "1", "2", "34", "3", "0", "", "", "", "0", "", "", "", "", "2", "7.553", "0.127", "0.002", "1.42558", "13.551", "0.141", "0.0015", "1.32039", "0.00001", "0", "", "", "0005", "", "A", "83", "XL", "93", "16", "72", "78.0", "88.6", "97.4", "", "", "", "", "95.7"]} -{"pcdb_id": 19156, "brand_name": "Navien", "model_name": "NCB500", "model_qualifier": "NCB500-2S+/41K", "winter_efficiency_pct": 89.8, "summer_efficiency_pct": 88.7, "comparative_hot_water_efficiency_pct": 70.3, "output_kw_max": 26.0, "final_year_of_manufacture": null, "raw": ["019156", "020178", "0", "2024/Jan/26 12:10", "Navien UK", "Navien", "NCB500", "NCB500-2S+/41K", "", "2022", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "26", "26", "A", "", "89.8", "88.7", "", "70.3", "", "2", "0", "2", "104", "1", "2", "34", "3", "0", "", "", "", "0", "", "", "", "", "2", "7.657", "0.122", "0.002", "1.54088", "13.69", "0.141", "0.001", "1.36976", "0.00001", "0", "", "", "0005", "", "A", "83", "XL", "93", "16", "72", "78.0", "91.1", "97.8", "", "", "", "", "96.5"]} -{"pcdb_id": 19157, "brand_name": "Vokera By Riello", "model_name": "EASI-HEAT i", "model_qualifier": "25C", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 87.6, "comparative_hot_water_efficiency_pct": 77.2, "output_kw_max": 19.38, "final_year_of_manufacture": null, "raw": ["019157", "020088", "0", "2024/Feb/02 11:47", "Vokera Ltd.", "Vokera By Riello", "EASI-HEAT i", "25C", "47-364-71", "2022", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "19.38", "19.38", "A", "", "88.5", "87.6", "", "77.2", "", "2", "", "", "104", "1", "2", "32", "3", "0", "", "", "", "0", "", "", "", "", "2", "6.824", "0.102", "0.003", "0.68563", "12.795", "0.107", "0.0011", "0.63873", "0.00002", "0", "", "", "0025", "", "A", "84", "XL", "93", "12", "63", "30.0", "87.3", "98.3", "", "", "", "", "96.2"]} -{"pcdb_id": 19158, "brand_name": "Vokera By Riello", "model_name": "EASI-HEAT i", "model_qualifier": "29C", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 85.1, "comparative_hot_water_efficiency_pct": 77.5, "output_kw_max": 24.38, "final_year_of_manufacture": null, "raw": ["019158", "020088", "0", "2024/Feb/02 11:58", "Vokera Ltd.", "Vokera By Riello", "EASI-HEAT i", "29C", "47-364-72", "2022", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.38", "24.38", "A", "", "88.5", "85.1", "", "77.5", "", "2", "", "", "104", "1", "2", "38", "3", "0", "", "", "", "0", "", "", "", "", "2", "6.798", "0.102", "0.001", "0.6857", "12.963", "0.118", "0.0016", "0.44078", "-0.00001", "0", "", "", "0025", "", "A", "84", "XL", "93", "12", "66", "32.0", "87.8", "98.0", "", "", "", "", "96.1"]} -{"pcdb_id": 19159, "brand_name": "Vokera By Riello", "model_name": "EASI-HEAT i", "model_qualifier": "25S", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 24.38, "final_year_of_manufacture": null, "raw": ["019159", "020088", "0", "2024/Feb/02 12:08", "Vokera Ltd.", "Vokera By Riello", "EASI-HEAT i", "25S", "47-364-18", "2022", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24.38", "24.38", "A", "", "88.5", "79.5", "", "58.0", "", "2", "", "", "102", "1", "2", "38", "3", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "93", "12", "66", "32.0", "87.8", "98.0", "", "", "", "", "96.1"]} -{"pcdb_id": 19160, "brand_name": "Navien", "model_name": "NCB500", "model_qualifier": "NCB500-1S+/32K", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 88.2, "comparative_hot_water_efficiency_pct": 70.2, "output_kw_max": 26.0, "final_year_of_manufacture": null, "raw": ["019160", "020178", "0", "2024/Jan/26 12:23", "Navien UK", "Navien", "NCB500", "NCB500-1S+/32K", "", "2022", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "26", "26", "A", "", "88.3", "88.2", "", "70.2", "", "2", "", "", "104", "1", "2", "34", "3", "0", "", "", "", "0", "", "", "", "", "2", "7.499", "0.119", "0.003", "1.36767", "13.389", "0.135", "0.001", "1.33151", "0.00002", "0", "", "", "0005", "", "A", "85", "XL", "93", "16", "72", "78.0", "88.6", "97.4", "", "", "", "", "95.7"]} -{"pcdb_id": 19161, "brand_name": "Navien", "model_name": "NCB500", "model_qualifier": "NCB500-1S+/32K", "winter_efficiency_pct": 89.8, "summer_efficiency_pct": 90.0, "comparative_hot_water_efficiency_pct": 71.6, "output_kw_max": 26.0, "final_year_of_manufacture": null, "raw": ["019161", "020178", "0", "2024/Jan/26 12:36", "Navien UK", "Navien", "NCB500", "NCB500-1S+/32K", "", "2022", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "26", "26", "A", "", "89.8", "90.0", "", "71.6", "", "2", "0", "2", "104", "1", "2", "34", "3", "0", "", "", "", "0", "", "", "", "", "2", "7.519", "0.118", "0.003", "1.40171", "13.466", "0.136", "0.0015", "1.33627", "0.00002", "0", "", "", "0005", "", "A", "85", "XL", "93", "16", "72", "78.0", "91.1", "97.8", "", "", "", "", "96.5"]} -{"pcdb_id": 19162, "brand_name": "Vaillant", "model_name": "ecoTEC plus 940", "model_qualifier": "VUI 30/40CS/1-5 (N-GB)", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 78.5, "comparative_hot_water_efficiency_pct": 72.7, "output_kw_max": 30.0, "final_year_of_manufacture": null, "raw": ["019162", "020033", "0", "2024/May/22 10:02", "Vaillant Group UK Ltd", "Vaillant", "ecoTEC plus 940", "VUI 30/40CS/1-5 (N-GB)", "47-044-96", "2023", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "30", "30", "A", "", "88.6", "78.5", "", "72.7", "", "2", "", "", "104", "1", "2", "39", "1", "0", "", "", "", "0", "", "", "", "", "2", "7.245", "0.153", "0.002", "1.1099", "13.899", "0.182", "0.0002", "0.33326", "0.00002", "0", "", "", "00C5", "", "A", "86", "XL", "94", "15", "61", "55.0", "87.8", "98.4", "", "", "", "", "96.4"]} -{"pcdb_id": 19163, "brand_name": "Ariston", "model_name": "ALTEAS ONE+ NET 35", "model_qualifier": "3302395", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 62.6, "output_kw_max": 30.3, "final_year_of_manufacture": null, "raw": ["019163", "020102", "0", "2024/Jul/05 10:01", "Ariston S.p.A", "Ariston", "ALTEAS ONE+ NET 35", "3302395", "47-116-98", "2023", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "30.3", "30.3", "A", "", "88.7", "80.1", "", "62.6", "", "2", "", "", "104", "1", "2", "33", "5", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "", "", "0805", "", "A", "86", "XXL", "94", "6", "62", "46.0", "88.4", "98.5", "", "", "", "", "96.6"]} -{"pcdb_id": 19164, "brand_name": "Ariston", "model_name": "GENUS ONE+ WIFI 24", "model_qualifier": "3302396", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 62.6, "output_kw_max": 21.5, "final_year_of_manufacture": null, "raw": ["019164", "020102", "0", "2024/Jul/05 10:02", "Ariston S.p.A", "Ariston", "GENUS ONE+ WIFI 24", "3302396", "47-116-99", "2023", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "21.5", "21.5", "A", "", "88.8", "80.2", "", "62.6", "", "2", "", "", "104", "1", "2", "21", "5", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "", "", "0805", "", "A", "86", "XL", "94", "7", "57", "40.0", "88.5", "98.7", "", "", "", "", "96.7"]} -{"pcdb_id": 19165, "brand_name": "Ariston", "model_name": "GENUS ONE+ WIFI 30", "model_qualifier": "3302397", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 62.6, "output_kw_max": 27.5, "final_year_of_manufacture": null, "raw": ["019165", "020102", "0", "2024/Jul/05 10:02", "Ariston S.p.A", "Ariston", "GENUS ONE+ WIFI 30", "3302397", "47-888-01", "2023", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "27.5", "27.5", "A", "", "88.8", "80.2", "", "62.6", "", "2", "", "", "104", "1", "2", "29", "5", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "", "", "0805", "", "A", "85", "XL", "94", "7", "62", "45.0", "88.8", "98.5", "", "", "", "", "96.6"]} -{"pcdb_id": 19166, "brand_name": "Ariston", "model_name": "GENUS ONE+ WIFI 35", "model_qualifier": "3302398", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 62.6, "output_kw_max": 30.3, "final_year_of_manufacture": null, "raw": ["019166", "020102", "0", "2024/Jul/05 10:03", "Ariston S.p.A", "Ariston", "GENUS ONE+ WIFI 35", "3302398", "47-888-02", "2023", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "30.3", "30.3", "A", "", "88.7", "80.1", "", "62.6", "", "2", "", "", "104", "1", "2", "33", "5", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "", "", "0805", "", "A", "86", "XXL", "94", "6", "62", "46.0", "88.4", "98.5", "", "", "", "", "96.6"]} -{"pcdb_id": 19167, "brand_name": "Baxi", "model_name": "PLATINUM COMPACT 25 COMBI", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 86.7, "comparative_hot_water_efficiency_pct": 80.2, "output_kw_max": 20.0, "final_year_of_manufacture": null, "raw": ["019167", "020101", "0", "2024/Oct/16 16:24", "Baxi Heating UK Ltd", "Baxi", "PLATINUM COMPACT 25 COMBI", "", "47-077-71", "2023", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "20", "20", "A", "", "88.4", "86.7", "", "80.2", "", "2", "", "", "104", "1", "2", "28", "3", "0", "", "", "", "0", "", "", "", "", "1", "6.563", "0.102", "0.0005", "0.46696", "", "", "", "", "", "0", "", "", "0405", "", "A", "90", "XL", "93", "15", "67", "40.0", "88.0", "97.8", "", "", "", "", "95.9"]} -{"pcdb_id": 19168, "brand_name": "Baxi", "model_name": "PLATINUM COMPACT 30 COMBI", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 86.7, "comparative_hot_water_efficiency_pct": 79.3, "output_kw_max": 20.0, "final_year_of_manufacture": null, "raw": ["019168", "020101", "0", "2024/Oct/16 16:30", "Baxi Heating UK Ltd", "Baxi", "PLATINUM COMPACT 30 COMBI", "", "47-077-72", "2023", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "20", "20", "A", "", "88.4", "86.7", "", "79.3", "", "2", "", "", "104", "1", "2", "38", "3", "0", "", "", "", "0", "", "", "", "", "1", "6.641", "0.105", "0.001", "0.53909", "", "", "", "", "", "0", "", "", "0405", "", "A", "89", "XL", "93", "15", "73", "40.0", "88.0", "97.8", "", "", "", "", "95.9"]} -{"pcdb_id": 19169, "brand_name": "Baxi", "model_name": "PLATINUM COMPACT 36 COMBI", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 86.7, "comparative_hot_water_efficiency_pct": 81.4, "output_kw_max": 25.0, "final_year_of_manufacture": null, "raw": ["019169", "020101", "0", "2024/Oct/16 16:34", "Baxi Heating UK Ltd", "Baxi", "PLATINUM COMPACT 36 COMBI", "", "47-077-73", "2023", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "25", "25", "A", "", "88.4", "86.7", "", "81.4", "", "2", "", "", "104", "1", "2", "72", "3", "0", "", "", "", "0", "", "", "", "", "1", "6.47", "0.102", "0.0015", "0.37374", "", "", "", "", "", "0", "", "", "0405", "", "A", "89", "XL", "93", "15", "92", "40.0", "88.1", "97.8", "", "", "", "", "96.0"]} -{"pcdb_id": 19170, "brand_name": "Baxi", "model_name": "424 COMBI 2.1", "model_qualifier": "", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 86.8, "comparative_hot_water_efficiency_pct": 80.4, "output_kw_max": 20.0, "final_year_of_manufacture": null, "raw": ["019170", "020101", "0", "2024/Oct/16 16:39", "Baxi Heating UK Ltd", "Baxi", "424 COMBI 2.1", "", "47-077-74", "2024", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "20", "20", "A", "", "88.9", "86.8", "", "80.4", "", "2", "", "", "104", "1", "2", "46", "4", "0", "", "", "", "0", "", "", "", "", "1", "6.548", "0.074", "0.0029", "0.44307", "", "", "", "", "", "0", "", "", "0405", "", "A", "93", "XL", "94", "8", "68", "40.0", "88.2", "99.0", "", "", "", "", "97.0"]} -{"pcdb_id": 19171, "brand_name": "Baxi", "model_name": "424 COMBI 2.1 LPG", "model_qualifier": "", "winter_efficiency_pct": 89.9, "summer_efficiency_pct": 88.7, "comparative_hot_water_efficiency_pct": 82.2, "output_kw_max": 20.0, "final_year_of_manufacture": null, "raw": ["019171", "020101", "0", "2024/Oct/16 16:44", "Baxi Heating UK Ltd", "Baxi", "424 COMBI 2.1 LPG", "", "47-077-74", "2024", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "20", "20", "A", "", "89.9", "88.7", "", "82.2", "", "2", "1", "", "104", "1", "2", "46", "4", "0", "", "", "", "0", "", "", "", "", "1", "6.548", "0.074", "0.0029", "0.44307", "", "", "", "", "", "0", "", "", "0405", "", "A", "93", "XL", "94", "8", "68", "40.0", "90.2", "101.2", "", "", "", "", "99.1"]} -{"pcdb_id": 19172, "brand_name": "Baxi", "model_name": "430 COMBI 2.1", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 86.7, "comparative_hot_water_efficiency_pct": 81.3, "output_kw_max": 25.0, "final_year_of_manufacture": null, "raw": ["019172", "020101", "0", "2024/Oct/16 16:49", "Baxi Heating UK Ltd", "Baxi", "430 COMBI 2.1", "", "47-077-75", "2024", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "25", "25", "A", "", "88.8", "86.7", "", "81.3", "", "2", "", "", "104", "1", "2", "61", "4", "0", "", "", "", "0", "", "", "", "", "1", "6.474", "0.071", "0.0021", "0.37197", "", "", "", "", "", "0", "", "", "0405", "", "A", "93", "XL", "94", "9", "79", "40.0", "88.0", "98.9", "", "", "", "", "96.9"]} -{"pcdb_id": 19173, "brand_name": "Baxi", "model_name": "430 COMBI 2.1 LPG", "model_qualifier": "", "winter_efficiency_pct": 89.9, "summer_efficiency_pct": 88.6, "comparative_hot_water_efficiency_pct": 83.2, "output_kw_max": 25.0, "final_year_of_manufacture": null, "raw": ["019173", "020101", "0", "2024/Oct/16 16:54", "Baxi Heating UK Ltd", "Baxi", "430 COMBI 2.1 LPG", "", "47-077-75", "2024", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "25", "25", "A", "", "89.9", "88.6", "", "83.2", "", "2", "1", "", "104", "1", "2", "61", "4", "0", "", "", "", "0", "", "", "", "", "1", "6.474", "0.071", "0.0021", "0.37197", "", "", "", "", "", "0", "", "", "0405", "", "A", "93", "XL", "94", "9", "79", "40.0", "90.0", "101.1", "", "", "", "", "99.0"]} -{"pcdb_id": 19174, "brand_name": "Baxi", "model_name": "436 COMBI 2.1", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 86.7, "comparative_hot_water_efficiency_pct": 81.4, "output_kw_max": 25.0, "final_year_of_manufacture": null, "raw": ["019174", "020101", "0", "2024/Oct/16 16:58", "Baxi Heating UK Ltd", "Baxi", "436 COMBI 2.1", "", "47-077-76", "2024", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "25", "25", "A", "", "88.8", "86.7", "", "81.4", "", "2", "", "", "104", "1", "2", "71", "4", "0", "", "", "", "0", "", "", "", "", "1", "6.47", "0.071", "0.0021", "0.37024", "", "", "", "", "", "0", "", "", "0405", "", "A", "93", "XL", "94", "9", "85", "40.0", "88.1", "98.8", "", "", "", "", "96.8"]} -{"pcdb_id": 19175, "brand_name": "Baxi", "model_name": "436 COMBI 2.1 LPG", "model_qualifier": "", "winter_efficiency_pct": 89.8, "summer_efficiency_pct": 88.6, "comparative_hot_water_efficiency_pct": 83.2, "output_kw_max": 25.0, "final_year_of_manufacture": null, "raw": ["019175", "020101", "0", "2024/Oct/16 17:02", "Baxi Heating UK Ltd", "Baxi", "436 COMBI 2.1 LPG", "", "47-077-76", "2024", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "25", "25", "A", "", "89.8", "88.6", "", "83.2", "", "2", "1", "", "104", "1", "2", "71", "4", "0", "", "", "", "0", "", "", "", "", "1", "6.47", "0.071", "0.0021", "0.37024", "", "", "", "", "", "0", "", "", "0405", "", "A", "93", "XL", "94", "9", "85", "40.0", "90.1", "101.0", "", "", "", "", "99.0"]} -{"pcdb_id": 19176, "brand_name": "Baxi", "model_name": "424 COMBI 2", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 62.4, "output_kw_max": 20.0, "final_year_of_manufacture": null, "raw": ["019176", "020101", "0", "2024/Dec/09 16:38", "Baxi Heating UK Ltd", "Baxi", "424 COMBI 2", "", "47-077-51", "2023", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "20", "20", "A", "", "88.5", "79.9", "", "62.4", "", "2", "", "", "104", "1", "2", "37", "4", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "", "", "0405", "", "A", "88", "XL", "93", "14", "76", "40.0", "88.2", "97.9", "", "", "", "", "96.1"]} -{"pcdb_id": 19177, "brand_name": "Baxi", "model_name": "430 COMBI 2", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 62.3, "output_kw_max": 20.0, "final_year_of_manufacture": null, "raw": ["019177", "020101", "0", "2024/Dec/09 16:43", "Baxi Heating UK Ltd", "Baxi", "430 COMBI 2", "", "47-077-52", "2023", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "20", "20", "A", "", "88.4", "79.8", "", "62.3", "", "2", "", "", "104", "1", "2", "26", "4", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "", "", "0405", "", "A", "89", "XL", "93", "14", "70", "40.0", "88.0", "97.8", "", "", "", "", "95.9"]} -{"pcdb_id": 19178, "brand_name": "Worcester", "model_name": "Greenstar 8000+", "model_qualifier": "GR8701iW 40 C LPG", "winter_efficiency_pct": 90.6, "summer_efficiency_pct": 88.9, "comparative_hot_water_efficiency_pct": 73.5, "output_kw_max": 33.7, "final_year_of_manufacture": null, "raw": ["019178", "020051", "0", "2024/Dec/04 15:32", "Bosch Thermotechnology Ltd", "Worcester", "Greenstar 8000+", "GR8701iW 40 C LPG", "47-800-53", "2024", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "16.9", "33.7", "A", "", "90.6", "88.9", "", "73.5", "", "2", "0", "2", "104", "1", "2", "48", "2", "0", "", "", "", "0", "", "", "", "", "1", "7.323", "0.112", "0.01", "1.16664", "", "", "", "", "", "0", "", "", "8305", "", "A", "86", "XL", "94", "13", "68", "71.0", "90.9", "99.9", "", "", "", "", "98.2"]} -{"pcdb_id": 19179, "brand_name": "Worcester", "model_name": "Greenstar 8000+", "model_qualifier": "GR8701iW 45 C LPG", "winter_efficiency_pct": 90.7, "summer_efficiency_pct": 89.1, "comparative_hot_water_efficiency_pct": 72.5, "output_kw_max": 33.8, "final_year_of_manufacture": null, "raw": ["019179", "020051", "0", "2024/Dec/04 19:07", "Bosch Thermotechnology Ltd", "Worcester", "Greenstar 8000+", "GR8701iW 45 C LPG", "47-800-54", "2024", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "16.9", "33.8", "A", "", "90.7", "89.1", "", "72.5", "", "2", "0", "2", "104", "1", "2", "48", "1", "0", "", "", "", "0", "", "", "", "", "1", "7.425", "0.106", "0.002", "1.32645", "", "", "", "", "", "0", "", "", "8305", "", "A", "86", "XL", "94", "13", "62", "71.0", "91.5", "100.1", "", "", "", "", "98.5"]} -{"pcdb_id": 19180, "brand_name": "Worcester", "model_name": "Greenstar 8000+", "model_qualifier": "GR8701iW 50 C LPG", "winter_efficiency_pct": 90.6, "summer_efficiency_pct": 89.1, "comparative_hot_water_efficiency_pct": 74.5, "output_kw_max": 33.8, "final_year_of_manufacture": null, "raw": ["019180", "020051", "0", "2024/Dec/04 19:23", "Bosch Thermotechnology Ltd", "Worcester", "Greenstar 8000+", "GR8701iW 50 C LPG", "47-800-55", "2024", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "16.9", "33.8", "A", "", "90.6", "89.1", "", "74.5", "", "2", "0", "2", "104", "1", "2", "48", "1", "0", "", "", "", "0", "", "", "", "", "1", "7.228", "0.115", "0.0025", "1.13294", "", "", "", "", "", "0", "", "", "8305", "", "A", "87", "XL", "94", "13", "62", "71.0", "91.5", "99.7", "", "", "", "", "98.2"]} -{"pcdb_id": 19181, "brand_name": "Worcester", "model_name": "Greenstar 8000+", "model_qualifier": "GR8701iW 45 R NG", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 42.6, "final_year_of_manufacture": null, "raw": ["019181", "020051", "0", "2024/Dec/04 14:46", "Bosch Thermotechnology Ltd", "Worcester", "Greenstar 8000+", "GR8701iW 45 R NG", "41-800-32", "2024", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "21.3", "42.6", "A", "", "89.2", "80.2", "", "58.6", "", "2", "", "", "102", "1", "2", "84", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "8305", "", "", "", "", "94", "14", "91", "67.0", "88.7", "99.5", "", "", "", "", "97.4"]} -{"pcdb_id": 19182, "brand_name": "Worcester", "model_name": "Greenstar 8000+", "model_qualifier": "GR8701iW 50 R NG", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 47.8, "final_year_of_manufacture": null, "raw": ["019182", "020051", "0", "2025/Jan/03 08:45", "Bosch Thermotechnology Ltd", "Worcester", "Greenstar 8000+", "GR8701iW 50 R NG", "41-800-33", "2024", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "23.9", "47.8", "A", "", "89.0", "80.0", "", "58.5", "", "2", "", "", "102", "1", "2", "84", "1", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "8305", "", "", "", "", "94", "14", "85", "67.0", "88.6", "99.2", "", "", "", "", "97.2"]} -{"pcdb_id": 19183, "brand_name": "Worcester", "model_name": "Greenstar 8000+", "model_qualifier": "GR8701iW 30 S LPG", "winter_efficiency_pct": 90.5, "summer_efficiency_pct": 81.5, "comparative_hot_water_efficiency_pct": 59.5, "output_kw_max": 29.6, "final_year_of_manufacture": null, "raw": ["019183", "020051", "0", "2024/Dec/19 14:44", "Bosch Thermotechnology Ltd", "Worcester", "Greenstar 8000+", "GR8701iW 30 S LPG", "41-800-34", "2024", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "14.8", "29.6", "A", "", "90.5", "81.5", "", "59.5", "", "2", "0", "2", "102", "1", "2", "67", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "8305", "", "", "", "", "94", "14", "81", "71.0", "91.0", "99.7", "", "", "", "", "98.1"]} -{"pcdb_id": 19184, "brand_name": "Worcester", "model_name": "Greenstar 8000+", "model_qualifier": "GR8701iW 35 S LPG", "winter_efficiency_pct": 90.5, "summer_efficiency_pct": 81.5, "comparative_hot_water_efficiency_pct": 59.5, "output_kw_max": 33.7, "final_year_of_manufacture": null, "raw": ["019184", "020051", "0", "2024/Dec/19 15:56", "Bosch Thermotechnology Ltd", "Worcester", "Greenstar 8000+", "GR8701iW 35 S LPG", "41-800-35", "2024", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "16.9", "33.7", "A", "", "90.5", "81.5", "", "59.5", "", "2", "0", "2", "102", "1", "2", "48", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "8305", "", "", "", "", "94", "13", "68", "71.0", "90.9", "99.7", "", "", "", "", "98.1"]} -{"pcdb_id": 19185, "brand_name": "Worcester", "model_name": "Greenstar 8000+", "model_qualifier": "GR8701iW 30 R LPG", "winter_efficiency_pct": 90.5, "summer_efficiency_pct": 81.5, "comparative_hot_water_efficiency_pct": 59.5, "output_kw_max": 29.6, "final_year_of_manufacture": null, "raw": ["019185", "020051", "0", "2024/Dec/19 14:58", "Bosch Thermotechnology Ltd", "Worcester", "Greenstar 8000+", "GR8701iW 30 R LPG", "41-800-36", "2024", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "14.8", "29.6", "A", "", "90.5", "81.5", "", "59.5", "", "2", "0", "2", "102", "1", "2", "67", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "8305", "", "", "", "", "94", "14", "81", "71.0", "91.0", "99.7", "", "", "", "", "98.1"]} -{"pcdb_id": 19186, "brand_name": "Worcester", "model_name": "Greenstar 8000+", "model_qualifier": "GR8701iW 35 R LPG", "winter_efficiency_pct": 90.5, "summer_efficiency_pct": 81.5, "comparative_hot_water_efficiency_pct": 59.5, "output_kw_max": 33.7, "final_year_of_manufacture": null, "raw": ["019186", "020051", "0", "2024/Dec/19 15:57", "Bosch Thermotechnology Ltd", "Worcester", "Greenstar 8000+", "GR8701iW 35 R LPG", "41-800-37", "2024", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "16.9", "33.7", "A", "", "90.5", "81.5", "", "59.5", "", "2", "0", "2", "102", "1", "2", "48", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "8305", "", "", "", "", "94", "13", "68", "71.0", "90.9", "99.7", "", "", "", "", "98.1"]} -{"pcdb_id": 19187, "brand_name": "Worcester", "model_name": "Greenstar 8000+", "model_qualifier": "GR8701iW 40 R LPG", "winter_efficiency_pct": 90.6, "summer_efficiency_pct": 81.6, "comparative_hot_water_efficiency_pct": 59.6, "output_kw_max": 39.8, "final_year_of_manufacture": null, "raw": ["019187", "020051", "0", "2024/Dec/04 16:12", "Bosch Thermotechnology Ltd", "Worcester", "Greenstar 8000+", "GR8701iW 40 R LPG", "41-800-38", "2024", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "19.9", "39.8", "A", "", "90.6", "81.6", "", "59.6", "", "2", "0", "2", "102", "1", "2", "75", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "8305", "", "", "", "", "94", "14", "86", "71.0", "91.2", "99.9", "", "", "", "", "98.3"]} -{"pcdb_id": 19188, "brand_name": "Worcester", "model_name": "Greenstar 8000+", "model_qualifier": "GR8701iW 45 R LPG", "winter_efficiency_pct": 90.2, "summer_efficiency_pct": 81.2, "comparative_hot_water_efficiency_pct": 59.3, "output_kw_max": 42.6, "final_year_of_manufacture": null, "raw": ["019188", "020051", "0", "2024/Dec/04 17:34", "Bosch Thermotechnology Ltd", "Worcester", "Greenstar 8000+", "GR8701iW 45 R LPG", "41-800-39", "2024", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "21.3", "42.6", "A", "", "90.2", "81.2", "", "59.3", "", "2", "0", "2", "102", "1", "2", "84", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "8305", "", "", "", "", "94", "14", "91", "67.0", "90.9", "99.0", "", "", "", "", "97.5"]} -{"pcdb_id": 19189, "brand_name": "Worcester", "model_name": "Greenstar 8000+", "model_qualifier": "GR8701iW 50 R LPG", "winter_efficiency_pct": 90.1, "summer_efficiency_pct": 81.1, "comparative_hot_water_efficiency_pct": 59.3, "output_kw_max": 47.8, "final_year_of_manufacture": null, "raw": ["019189", "020051", "0", "2024/Dec/04 18:10", "Bosch Thermotechnology Ltd", "Worcester", "Greenstar 8000+", "GR8701iW 50 R LPG", "41-800-40", "2024", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "23.9", "47.8", "A", "", "90.1", "81.1", "", "59.3", "", "2", "0", "2", "102", "1", "2", "84", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "8305", "", "", "", "", "94", "14", "91", "67.0", "90.8", "98.9", "", "", "", "", "97.4"]} -{"pcdb_id": 19190, "brand_name": "Warmflow", "model_name": "B21", "model_qualifier": "Agentis HVO Boiler House 21", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 80.9, "comparative_hot_water_efficiency_pct": 59.1, "output_kw_max": 21.0, "final_year_of_manufacture": null, "raw": ["019190", "020103", "0", "2025/Feb/25 15:41", "Warmflow Engineering Ltd", "Warmflow", "B21", "Agentis HVO Boiler House 21", "", "2019", "current", "71", "1", "1", "1", "0", "", "", "2", "3", "2", "15", "21", "A", "", "88.7", "80.9", "", "59.1", "", "2", "", "", "201", "1", "1", "152", "0", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "91", "49", "188", "112.0", "91.8", "96.2", "", "", "", "", "95.4"]} -{"pcdb_id": 19191, "brand_name": "Warmflow", "model_name": "E21", "model_qualifier": "Agentis HVO External 21", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 80.9, "comparative_hot_water_efficiency_pct": 59.1, "output_kw_max": 21.0, "final_year_of_manufacture": null, "raw": ["019191", "020103", "0", "2025/Feb/25 15:45", "Warmflow Engineering Ltd", "Warmflow", "E21", "Agentis HVO External 21", "", "2019", "current", "71", "1", "2", "1", "0", "", "", "2", "3", "2", "15", "21", "A", "", "88.7", "80.9", "", "59.1", "", "2", "", "", "201", "1", "1", "152", "0", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "91", "49", "188", "112.0", "91.8", "96.2", "", "", "", "", "95.4"]} -{"pcdb_id": 19192, "brand_name": "Warmflow", "model_name": "I21", "model_qualifier": "Agentis HVO Internal 21", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 80.9, "comparative_hot_water_efficiency_pct": 59.1, "output_kw_max": 21.0, "final_year_of_manufacture": null, "raw": ["019192", "020103", "0", "2025/Feb/25 16:03", "Warmflow Engineering Ltd", "Warmflow", "I21", "Agentis HVO Internal 21", "", "2019", "current", "71", "1", "1", "1", "0", "", "", "2", "3", "2", "15", "21", "A", "", "88.7", "80.9", "", "59.1", "", "2", "", "", "201", "1", "1", "152", "0", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "91", "49", "188", "112.0", "91.8", "96.2", "", "", "", "", "95.4"]} -{"pcdb_id": 19193, "brand_name": "Warmflow", "model_name": "I21C", "model_qualifier": "Agentis HVO Internal Combi 21", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 90.0, "comparative_hot_water_efficiency_pct": 64.5, "output_kw_max": 21.0, "final_year_of_manufacture": null, "raw": ["019193", "020103", "0", "2025/Feb/27 08:58", "Warmflow Engineering Ltd", "Warmflow", "I21C", "Agentis HVO Internal Combi 21", "", "2019", "current", "71", "1", "1", "2", "0", "", "", "2", "3", "2", "15", "21", "A", "", "88.7", "90.0", "", "64.5", "", "2", "", "", "203", "1", "1", "163", "3", "1", "2", "0", "38", "0", "20", "4", "58", "", "1", "8.487", "0.117", "0.0", "2.30726", "", "", "", "", "", "", "", "", "0003", "", "A", "82", "XL", "91", "53", "224", "112.0", "91.1", "96.5", "", "", "", "", "95.5"]} -{"pcdb_id": 19194, "brand_name": "Warmflow", "model_name": "E21C", "model_qualifier": "Agentis HVO External Combi 21", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 90.0, "comparative_hot_water_efficiency_pct": 64.5, "output_kw_max": 21.0, "final_year_of_manufacture": null, "raw": ["019194", "020103", "0", "2025/Feb/25 16:56", "Warmflow Engineering Ltd", "Warmflow", "E21C", "Agentis HVO External Combi 21", "", "2019", "current", "71", "1", "2", "2", "0", "", "", "2", "3", "2", "15", "21", "A", "", "88.7", "90.0", "", "64.5", "", "2", "", "", "203", "1", "1", "163", "3", "1", "2", "0", "38", "0", "20", "4", "58", "", "1", "8.487", "0.117", "0.0", "2.30726", "", "", "", "", "", "", "", "", "0003", "", "A", "82", "XL", "91", "53", "224", "112.0", "91.1", "96.5", "", "", "", "", "95.5"]} -{"pcdb_id": 19195, "brand_name": "Warmflow", "model_name": "B26", "model_qualifier": "Agentis HVO Boiler House 26", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 27.0, "final_year_of_manufacture": null, "raw": ["019195", "020103", "0", "2025/Feb/26 09:51", "Warmflow Engineering Ltd", "Warmflow", "B26", "Agentis HVO Boiler House 26", "", "2019", "current", "71", "1", "1", "1", "0", "", "", "2", "3", "2", "21", "27", "A", "", "88.0", "80.2", "", "58.6", "", "2", "", "", "201", "1", "1", "146", "0", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "90", "47", "180", "110.0", "90.8", "94.7", "", "", "", "", "94.0"]} -{"pcdb_id": 19196, "brand_name": "Warmflow", "model_name": "E26", "model_qualifier": "Agentis HVO External 26", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 27.0, "final_year_of_manufacture": null, "raw": ["019196", "020103", "0", "2025/Feb/26 10:07", "Warmflow Engineering Ltd", "Warmflow", "E26", "Agentis HVO External 26", "", "2019", "current", "71", "1", "2", "1", "0", "", "", "2", "3", "2", "21", "27", "A", "", "88.0", "80.2", "", "58.6", "", "2", "", "", "201", "1", "1", "146", "0", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "90", "47", "180", "110.0", "90.8", "94.7", "", "", "", "", "94.0"]} -{"pcdb_id": 19197, "brand_name": "Warmflow", "model_name": "I26", "model_qualifier": "Agentis HVO Internal 26", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 27.0, "final_year_of_manufacture": null, "raw": ["019197", "020103", "0", "2025/Feb/26 10:16", "Warmflow Engineering Ltd", "Warmflow", "I26", "Agentis HVO Internal 26", "", "2019", "current", "71", "1", "1", "1", "0", "", "", "2", "3", "2", "21", "27", "A", "", "88.0", "80.2", "", "58.6", "", "2", "", "", "201", "1", "1", "146", "0", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "90", "47", "180", "110.0", "90.8", "94.7", "", "", "", "", "94.0"]} -{"pcdb_id": 19198, "brand_name": "Warmflow", "model_name": "I26C", "model_qualifier": "Agentis HVO Internal Combi 26", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 90.0, "comparative_hot_water_efficiency_pct": 62.6, "output_kw_max": 27.0, "final_year_of_manufacture": null, "raw": ["019198", "020103", "0", "2025/Feb/26 10:33", "Warmflow Engineering Ltd", "Warmflow", "I26C", "Agentis HVO Internal Combi 26", "", "2019", "current", "71", "1", "1", "2", "0", "", "", "2", "3", "2", "21", "27", "A", "", "88.2", "90.0", "", "62.6", "", "2", "", "", "203", "1", "1", "140", "3", "1", "2", "0", "38", "0", "20", "4", "58", "", "1", "8.751", "0.108", "0.0", "2.56085", "", "", "", "", "", "", "", "", "0003", "", "A", "83", "XL", "90", "51", "196", "110.0", "91.1", "95.1", "", "", "", "", "94.3"]} -{"pcdb_id": 19199, "brand_name": "Warmflow", "model_name": "E26C", "model_qualifier": "Agentis HVO External Combi 26", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 90.0, "comparative_hot_water_efficiency_pct": 62.6, "output_kw_max": 27.0, "final_year_of_manufacture": null, "raw": ["019199", "020103", "0", "2025/Feb/26 10:55", "Warmflow Engineering Ltd", "Warmflow", "E26C", "Agentis HVO External Combi 26", "", "2019", "current", "71", "1", "2", "2", "0", "", "", "2", "3", "2", "21", "27", "A", "", "88.2", "90.0", "", "62.6", "", "2", "", "", "203", "1", "1", "140", "3", "1", "2", "0", "38", "0", "20", "4", "58", "", "1", "8.751", "0.108", "0.0", "2.56085", "", "", "", "", "", "", "", "", "0003", "", "A", "83", "XL", "90", "51", "196", "110.0", "91.1", "95.1", "", "", "", "", "94.3"]} -{"pcdb_id": 19200, "brand_name": "Warmflow", "model_name": "B33", "model_qualifier": "Agentis HVO Boiler House 33", "winter_efficiency_pct": 87.1, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 32.7, "final_year_of_manufacture": null, "raw": ["019200", "020103", "0", "2025/Feb/27 10:21", "Warmflow Engineering Ltd", "Warmflow", "B33", "Agentis HVO Boiler House 33", "", "2019", "current", "71", "1", "1", "1", "0", "", "", "2", "3", "2", "27", "32.7", "A", "", "87.1", "79.3", "", "57.9", "", "2", "", "", "201", "1", "1", "147", "0", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "90", "45", "182", "119.0", "89.8", "93.0", "", "", "", "", "92.3"]} -{"pcdb_id": 19201, "brand_name": "Warmflow", "model_name": "E33", "model_qualifier": "Agentis HVO External 33", "winter_efficiency_pct": 87.1, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 32.7, "final_year_of_manufacture": null, "raw": ["019201", "020103", "0", "2025/Feb/27 10:31", "Warmflow Engineering Ltd", "Warmflow", "E33", "Agentis HVO External 33", "", "2019", "current", "71", "1", "2", "1", "0", "", "", "2", "3", "2", "27", "32.7", "A", "", "87.1", "79.3", "", "57.9", "", "2", "", "", "201", "1", "1", "147", "0", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "90", "45", "182", "119.0", "89.8", "93.0", "", "", "", "", "92.3"]} -{"pcdb_id": 19202, "brand_name": "Warmflow", "model_name": "I33", "model_qualifier": "Agentis HVO Internal 33", "winter_efficiency_pct": 87.1, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 32.7, "final_year_of_manufacture": null, "raw": ["019202", "020103", "0", "2025/Feb/27 10:47", "Warmflow Engineering Ltd", "Warmflow", "I33", "Agentis HVO Internal 33", "", "2019", "current", "71", "1", "1", "1", "0", "", "", "2", "3", "2", "27", "32.7", "A", "", "87.1", "79.3", "", "57.9", "", "2", "", "", "201", "1", "1", "147", "0", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "90", "45", "182", "119.0", "89.8", "93.0", "", "", "", "", "92.3"]} -{"pcdb_id": 19203, "brand_name": "Warmflow", "model_name": "I33C", "model_qualifier": "Agentis HVO Internal Combi 33", "winter_efficiency_pct": 87.4, "summer_efficiency_pct": 89.9, "comparative_hot_water_efficiency_pct": 57.3, "output_kw_max": 32.7, "final_year_of_manufacture": null, "raw": ["019203", "020103", "0", "2025/Feb/27 11:15", "Warmflow Engineering Ltd", "Warmflow", "I33C", "Agentis HVO Internal Combi 33", "", "2019", "current", "71", "1", "1", "2", "0", "", "", "2", "3", "2", "27", "32.7", "A", "", "87.4", "89.9", "", "57.3", "", "2", "", "", "203", "1", "1", "148", "3", "1", "2", "0", "38", "0", "20", "4", "58", "", "1", "9.552", "0.088", "0.0", "3.31777", "", "", "", "", "", "", "", "", "0003", "", "A", "85", "XL", "90", "49", "206", "119.0", "90.7", "93.3", "", "", "", "", "92.8"]} -{"pcdb_id": 19204, "brand_name": "Warmflow", "model_name": "E33C", "model_qualifier": "Agentis HVO External Combi 33", "winter_efficiency_pct": 87.4, "summer_efficiency_pct": 89.9, "comparative_hot_water_efficiency_pct": 57.3, "output_kw_max": 32.7, "final_year_of_manufacture": null, "raw": ["019204", "020103", "0", "2025/Feb/27 11:28", "Warmflow Engineering Ltd", "Warmflow", "E33C", "Agentis HVO External Combi 33", "", "2019", "current", "71", "1", "2", "2", "0", "", "", "2", "3", "2", "27", "32.7", "A", "", "87.4", "89.9", "", "57.3", "", "2", "", "", "203", "1", "1", "148", "3", "1", "2", "0", "38", "0", "20", "4", "58", "", "1", "9.552", "0.088", "0.0", "3.31777", "", "", "", "", "", "", "", "", "0003", "", "A", "85", "XL", "90", "49", "206", "119.0", "90.7", "93.3", "", "", "", "", "92.8"]} -{"pcdb_id": 19205, "brand_name": "Warmflow", "model_name": "E44", "model_qualifier": "Agentis HVO External 44", "winter_efficiency_pct": 87.5, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 44.0, "final_year_of_manufacture": null, "raw": ["019205", "020103", "0", "2025/Feb/26 15:51", "Warmflow Engineering Ltd", "Warmflow", "E44", "Agentis HVO External 44", "", "2019", "current", "71", "1", "2", "1", "0", "", "", "2", "3", "2", "33", "44", "A", "", "87.5", "79.7", "", "58.2", "", "2", "", "", "201", "1", "1", "190", "0", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "91", "45", "235", "123.0", "89.7", "94.1", "", "", "", "", "93.2"]} -{"pcdb_id": 19206, "brand_name": "Warmflow", "model_name": "I44", "model_qualifier": "Agentis HVO Internal 44", "winter_efficiency_pct": 87.5, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 44.0, "final_year_of_manufacture": null, "raw": ["019206", "020103", "0", "2025/Feb/26 16:07", "Warmflow Engineering Ltd", "Warmflow", "I44", "Agentis HVO Internal 44", "", "2019", "current", "71", "1", "1", "1", "0", "", "", "2", "3", "2", "33", "44", "A", "", "87.5", "79.7", "", "58.2", "", "2", "", "", "201", "1", "1", "190", "0", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "91", "45", "235", "123.0", "89.7", "94.1", "", "", "", "", "93.2"]} -{"pcdb_id": 19207, "brand_name": "Vaillant", "model_name": "ecoTEC plus 610", "model_qualifier": "VU 10CS/1-5 (N-GB)", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 10.0, "final_year_of_manufacture": null, "raw": ["019207", "020033", "0", "2025/Mar/06 10:18", "Vaillant Group UK Ltd", "Vaillant", "ecoTEC plus 610", "VU 10CS/1-5 (N-GB)", "41-694-45", "2023", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "10", "10", "A", "", "89.2", "80.2", "", "58.6", "", "2", "1", "", "102", "1", "2", "17", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "00C5", "", "", "", "", "92", "13", "50", "42.0", "89.4", "99.7", "", "", "", "", "97.7"]} -{"pcdb_id": 19208, "brand_name": "Vaillant", "model_name": "ecoTEC plus 615", "model_qualifier": "VU 15CS/1-5 (N-GB)", "winter_efficiency_pct": 89.3, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 58.7, "output_kw_max": 15.0, "final_year_of_manufacture": null, "raw": ["019208", "020033", "0", "2025/Mar/06 10:38", "Vaillant Group UK Ltd", "Vaillant", "ecoTEC plus 615", "VU 15CS/1-5 (N-GB)", "41-694-46", "2023", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "15", "15", "A", "", "89.3", "80.3", "", "58.7", "", "2", "1", "", "102", "1", "2", "22", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "00C5", "", "", "", "", "93", "13", "53", "42.0", "89.3", "100.0", "", "", "", "", "98.0"]} -{"pcdb_id": 19209, "brand_name": "Vaillant", "model_name": "ecoTEC plus 620", "model_qualifier": "VU 20CS/1-5 (N-GB)", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 80.4, "comparative_hot_water_efficiency_pct": 58.7, "output_kw_max": 20.0, "final_year_of_manufacture": null, "raw": ["019209", "020033", "0", "2025/Mar/06 14:18", "Vaillant Group UK Ltd", "Vaillant", "ecoTEC plus 620", "VU 20CS/1-5 (N-GB)", "41-694-47", "2023", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "20", "20", "A", "", "89.4", "80.4", "", "58.7", "", "2", "1", "", "102", "1", "2", "31", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "00C5", "", "", "", "", "93", "14", "60", "47.0", "89.5", "100.2", "", "", "", "", "98.2"]} -{"pcdb_id": 19210, "brand_name": "Vaillant", "model_name": "ecoTEC plus 625", "model_qualifier": "VU 25C/S1-5 (N-GB)", "winter_efficiency_pct": 89.7, "summer_efficiency_pct": 80.7, "comparative_hot_water_efficiency_pct": 59.0, "output_kw_max": 25.0, "final_year_of_manufacture": null, "raw": ["019210", "020033", "0", "2025/Mar/06 14:15", "Vaillant Group UK Ltd", "Vaillant", "ecoTEC plus 625", "VU 25C/S1-5 (N-GB)", "41-694-48", "2023", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "25", "25", "A", "", "89.7", "80.7", "", "59.0", "", "2", "1", "", "102", "1", "2", "28", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "00C5", "", "", "", "", "94", "15", "61", "48.0", "90.1", "100.8", "", "", "", "", "98.7"]} -{"pcdb_id": 19211, "brand_name": "Vaillant", "model_name": "ecoTEC plus 630", "model_qualifier": "VU 30CS/1-5 (N-GB)", "winter_efficiency_pct": 89.6, "summer_efficiency_pct": 80.6, "comparative_hot_water_efficiency_pct": 58.9, "output_kw_max": 30.0, "final_year_of_manufacture": null, "raw": ["019211", "020033", "0", "2025/Mar/06 14:13", "Vaillant Group UK Ltd", "Vaillant", "ecoTEC plus 630", "VU 30CS/1-5 (N-GB)", "41-694-49", "2023", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "30", "30", "A", "", "89.6", "80.6", "", "58.9", "", "2", "1", "", "102", "1", "2", "36", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "00C5", "", "", "", "", "94", "16", "68", "45.0", "90.0", "100.5", "", "", "", "", "98.5"]} -{"pcdb_id": 19212, "brand_name": "Vaillant", "model_name": "ecoTEC plus 826", "model_qualifier": "VUW 20/26CS/1-5 (N-GB)", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 63.1, "output_kw_max": 20.0, "final_year_of_manufacture": null, "raw": ["019212", "020033", "0", "2025/Mar/06 14:59", "Vaillant Group UK Ltd", "Vaillant", "ecoTEC plus 826", "VUW 20/26CS/1-5 (N-GB)", "47-044-92", "2023", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "20", "20", "A", "", "89.4", "80.8", "", "63.1", "", "2", "1", "", "104", "1", "2", "31", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "", "", "00C5", "", "A", "87", "XL", "93", "14", "60", "47.0", "89.5", "100.2", "", "001871", "", "", "98.2"]} -{"pcdb_id": 19213, "brand_name": "Vaillant", "model_name": "ecoTEC plus 832", "model_qualifier": "VUW 25/32CS/1-5 (N-GB)", "winter_efficiency_pct": 89.7, "summer_efficiency_pct": 81.1, "comparative_hot_water_efficiency_pct": 63.3, "output_kw_max": 25.0, "final_year_of_manufacture": null, "raw": ["019213", "020033", "0", "2025/Mar/06 16:34", "Vaillant Group UK Ltd", "Vaillant", "ecoTEC plus 832", "VUW 25/32CS/1-5 (N-GB)", "47-044-93", "2023", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "25", "25", "A", "", "89.7", "81.1", "", "63.3", "", "2", "1", "", "104", "1", "2", "28", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "", "", "00C5", "", "A", "84", "XL", "94", "15", "61", "49.0", "90.1", "100.8", "", "001894", "", "", "98.7"]} -{"pcdb_id": 19214, "brand_name": "Vaillant", "model_name": "ecoTEC plus 836", "model_qualifier": "VUW 30/36CS/1-5 (N-GB)", "winter_efficiency_pct": 89.6, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 63.2, "output_kw_max": 30.0, "final_year_of_manufacture": null, "raw": ["019214", "020033", "0", "2025/Mar/10 11:27", "Vaillant Group UK Ltd", "Vaillant", "ecoTEC plus 836", "VUW 30/36CS/1-5 (N-GB)", "47-044-94", "2023", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "30", "30", "A", "", "89.6", "81.0", "", "63.2", "", "2", "1", "", "104", "1", "2", "36", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "", "", "00C5", "", "A", "87", "XL", "94", "16", "68", "49.0", "90.0", "100.5", "", "", "", "", "98.5"]} -{"pcdb_id": 19215, "brand_name": "Worcester", "model_name": "Greenstar 8000+", "model_qualifier": "GR8701iW 40 C NG", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 85.2, "comparative_hot_water_efficiency_pct": 69.8, "output_kw_max": 33.7, "final_year_of_manufacture": null, "raw": ["019215", "020051", "0", "2025/Apr/14 12:12", "Bosch Thermotechnology Ltd", "Worcester", "Greenstar 8000+", "GR8701iW 40 C NG", "47-800-46", "2024", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "16.9", "33.7", "A", "", "88.2", "85.2", "", "69.8", "", "2", "", "", "104", "1", "2", "48", "2", "0", "", "", "", "0", "", "", "", "", "2", "7.545", "0.124", "0.0045", "1.36871", "13.689", "0.116", "0.0025", "1.12425", "0.00002", "0", "", "", "8305", "", "A", "86", "XL", "94", "13", "68", "71.0", "87.3", "97.6", "", "", "", "", "95.6"]} -{"pcdb_id": 19216, "brand_name": "Worcester", "model_name": "Greenstar 8000+", "model_qualifier": "GR8701iW 32 C NG", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 88.2, "comparative_hot_water_efficiency_pct": 71.2, "output_kw_max": 29.6, "final_year_of_manufacture": null, "raw": ["019216", "020051", "0", "2025/Apr/11 15:12", "Bosch Thermotechnology Ltd", "Worcester", "Greenstar 8000+", "GR8701iW 32 C NG", "47-800-44", "2024", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "14.8", "29.6", "A", "", "88.4", "88.2", "", "71.2", "", "2", "", "", "104", "1", "2", "40", "2", "0", "", "", "", "0", "", "", "", "", "2", "7.398", "0.118", "0.0035", "1.23834", "13.195", "0.104", "0.0025", "1.2317", "0.00001", "0", "", "", "8305", "", "A", "81", "XL", "93", "12", "61", "71.0", "87.5", "98.1", "", "", "", "", "96.1"]} -{"pcdb_id": 19217, "brand_name": "Worcester", "model_name": "Greenstar 8000+", "model_qualifier": "GR8701iW 36 C NG", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 86.2, "comparative_hot_water_efficiency_pct": 71.4, "output_kw_max": 33.7, "final_year_of_manufacture": null, "raw": ["019217", "020051", "0", "2025/Apr/11 15:22", "Bosch Thermotechnology Ltd", "Worcester", "Greenstar 8000+", "GR8701iW 36 C NG", "47-800-45", "2024", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "16.9", "33.7", "A", "", "88.2", "86.2", "", "71.4", "", "2", "", "", "104", "1", "2", "48", "2", "0", "", "", "", "0", "", "", "", "", "2", "7.372", "0.115", "0.006", "1.19876", "13.445", "0.106", "0.003", "1.0315", "0.00003", "0", "", "", "8305", "", "A", "80", "XL", "94", "13", "68", "71.0", "87.5", "97.4", "", "", "", "", "95.5"]} -{"pcdb_id": 19218, "brand_name": "Worcester", "model_name": "Greenstar 8000+ Style", "model_qualifier": "GR8701iW 32 CB NG Style", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 88.2, "comparative_hot_water_efficiency_pct": 71.2, "output_kw_max": 29.6, "final_year_of_manufacture": null, "raw": ["019218", "020051", "0", "2025/Apr/11 15:28", "Bosch Thermotechnology Ltd", "Worcester", "Greenstar 8000+ Style", "GR8701iW 32 CB NG Style", "47-800-49", "2024", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "14.8", "29.6", "A", "", "88.4", "88.2", "", "71.2", "", "2", "", "", "104", "1", "2", "40", "2", "0", "", "", "", "0", "", "", "", "", "2", "7.398", "0.118", "0.0035", "1.23834", "13.195", "0.104", "0.0025", "1.2317", "0.00001", "0", "", "", "8305", "", "A", "81", "XL", "93", "12", "61", "71.0", "87.5", "98.1", "", "", "", "", "96.1"]} -{"pcdb_id": 19219, "brand_name": "Worcester", "model_name": "Greenstar 8000+ Style", "model_qualifier": "GR8701iW 36 CB NG Style", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 86.2, "comparative_hot_water_efficiency_pct": 71.4, "output_kw_max": 33.7, "final_year_of_manufacture": null, "raw": ["019219", "020051", "0", "2025/Apr/11 15:32", "Bosch Thermotechnology Ltd", "Worcester", "Greenstar 8000+ Style", "GR8701iW 36 CB NG Style", "47-800-50", "2024", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "16.9", "33.7", "A", "", "88.2", "86.2", "", "71.4", "", "2", "", "", "104", "1", "2", "48", "2", "0", "", "", "", "0", "", "", "", "", "2", "7.372", "0.115", "0.006", "1.19876", "13.445", "0.106", "0.003", "1.0315", "0.00003", "0", "", "", "8305", "", "A", "80", "XL", "94", "13", "68", "71.0", "87.5", "97.4", "", "", "", "", "95.5"]} -{"pcdb_id": 19220, "brand_name": "Worcester", "model_name": "Greenstar 8000+", "model_qualifier": "GR8701iW 32 C LPG", "winter_efficiency_pct": 89.8, "summer_efficiency_pct": 90.3, "comparative_hot_water_efficiency_pct": 73.0, "output_kw_max": 29.6, "final_year_of_manufacture": null, "raw": ["019220", "020051", "0", "2025/Apr/14 10:17", "Bosch Thermotechnology Ltd", "Worcester", "Greenstar 8000+", "GR8701iW 32 C LPG", "47-800-51", "2024", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "14.8", "29.6", "A", "", "89.8", "90.3", "", "73.0", "", "2", "0", "2", "104", "1", "2", "40", "2", "0", "", "", "", "0", "", "", "", "", "2", "7.374", "0.118", "0.006", "1.21756", "13.226", "0.128", "0.0035", "1.20522", "0.00003", "0", "", "", "8305", "", "A", "81", "XL", "93", "12", "61", "71.0", "90.1", "98.5", "", "", "", "", "96.9"]} -{"pcdb_id": 19221, "brand_name": "Worcester", "model_name": "Greenstar 8000+", "model_qualifier": "GR8701iW 36 C LPG", "winter_efficiency_pct": 89.5, "summer_efficiency_pct": 90.3, "comparative_hot_water_efficiency_pct": 72.3, "output_kw_max": 33.7, "final_year_of_manufacture": null, "raw": ["019221", "020051", "0", "2025/Apr/14 10:58", "Bosch Thermotechnology Ltd", "Worcester", "Greenstar 8000+", "GR8701iW 36 C LPG", "47-800-52", "2024", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "16.9", "33.7", "A", "", "89.5", "90.3", "", "72.3", "", "2", "0", "2", "104", "1", "2", "48", "2", "0", "", "", "", "0", "", "", "", "", "2", "7.449", "0.119", "0.006", "1.28244", "13.35", "0.105", "0.0035", "1.27728", "0.00003", "0", "", "", "8305", "", "A", "80", "XL", "94", "13", "68", "71.0", "89.8", "97.6", "", "", "", "", "96.1"]} -{"pcdb_id": 19222, "brand_name": "Worcester", "model_name": "Greenstar 8000+", "model_qualifier": "GR8701iW 45 C NG", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 88.2, "comparative_hot_water_efficiency_pct": 71.7, "output_kw_max": 33.8, "final_year_of_manufacture": null, "raw": ["019222", "020051", "0", "2025/Apr/30 11:20", "Bosch Thermotechnology Ltd", "Worcester", "Greenstar 8000+", "GR8701iW 45 C NG", "47-800-47", "2024", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "16.9", "33.8", "A", "", "88.8", "88.2", "", "71.7", "", "2", "", "", "104", "1", "2", "48", "2", "0", "", "", "", "0", "", "", "", "", "2", "7.35", "0.12", "0.0035", "1.21388", "13.26", "0.136", "0.0015", "1.18565", "0.00002", "0", "", "", "8305", "", "A", "86", "XL", "94", "13", "68", "71.0", "88.3", "98.7", "", "", "", "", "96.7"]} -{"pcdb_id": 19223, "brand_name": "Worcester", "model_name": "Greenstar 8000+", "model_qualifier": "GR8701iW 50 C NG", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 87.1, "comparative_hot_water_efficiency_pct": 70.0, "output_kw_max": 33.8, "final_year_of_manufacture": null, "raw": ["019223", "020051", "0", "2025/Apr/30 13:46", "Bosch Thermotechnology Ltd", "Worcester", "Greenstar 8000+", "GR8701iW 50 C NG", "47-800-48", "2024", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "16.9", "33.8", "A", "", "88.9", "87.1", "", "70.0", "", "2", "", "", "104", "1", "2", "48", "2", "0", "", "", "", "0", "", "", "", "", "2", "7.518", "0.113", "0.006", "1.36354", "13.526", "0.127", "0.003", "1.24463", "0.00003", "0", "", "", "8305", "", "A", "87", "XL", "94", "13", "68", "71.0", "88.4", "98.8", "", "", "", "", "96.9"]} -{"pcdb_id": 19224, "brand_name": "Grant", "model_name": "VORTEX PRO 15-26", "model_qualifier": "", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 81.1, "comparative_hot_water_efficiency_pct": 59.2, "output_kw_max": 26.0, "final_year_of_manufacture": null, "raw": ["019224", "020089", "0", "2025/Apr/28 16:37", "Grant Engineering (UK) Ltd", "Grant", "VORTEX PRO 15-26", "", "", "2022", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "15", "26", "A", "", "88.9", "81.1", "", "59.2", "", "2", "", "", "201", "1", "1", "152", "0", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "92", "53", "188", "45.0", "92.6", "96.3", "", "", "", "", "95.6"]} -{"pcdb_id": 19225, "brand_name": "Grant", "model_name": "VORTEX PRO SYSTEM 15-26", "model_qualifier": "", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 81.1, "comparative_hot_water_efficiency_pct": 59.2, "output_kw_max": 26.0, "final_year_of_manufacture": null, "raw": ["019225", "020089", "0", "2025/Apr/28 16:55", "Grant Engineering (UK) Ltd", "Grant", "VORTEX PRO SYSTEM 15-26", "", "", "2022", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "15", "26", "A", "", "88.9", "81.1", "", "59.2", "", "2", "", "", "201", "1", "1", "152", "0", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "92", "53", "188", "45.0", "92.6", "96.3", "", "", "", "", "95.6"]} -{"pcdb_id": 19226, "brand_name": "Grant", "model_name": "VORTEX PRO EXTERNAL 15-26", "model_qualifier": "", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 81.1, "comparative_hot_water_efficiency_pct": 59.2, "output_kw_max": 26.0, "final_year_of_manufacture": null, "raw": ["019226", "020089", "0", "2025/Apr/29 10:34", "Grant Engineering (UK) Ltd", "Grant", "VORTEX PRO EXTERNAL 15-26", "", "", "2022", "current", "4", "1", "2", "1", "0", "", "", "2", "1", "2", "15", "26", "A", "", "88.9", "81.1", "", "59.2", "", "2", "", "", "201", "1", "1", "152", "0", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "92", "53", "188", "45.0", "92.6", "96.3", "", "", "", "", "95.6"]} -{"pcdb_id": 19227, "brand_name": "Grant", "model_name": "VORTEX BOILER HOUSE 15-26", "model_qualifier": "", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 81.1, "comparative_hot_water_efficiency_pct": 59.2, "output_kw_max": 26.0, "final_year_of_manufacture": null, "raw": ["019227", "020089", "0", "2025/Apr/29 11:22", "Grant Engineering (UK) Ltd", "Grant", "VORTEX BOILER HOUSE 15-26", "", "", "2022", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "15", "26", "A", "", "88.9", "81.1", "", "59.2", "", "2", "", "", "201", "1", "1", "152", "0", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "92", "53", "188", "45.0", "92.6", "96.3", "", "", "", "", "95.6"]} -{"pcdb_id": 19228, "brand_name": "Worcester", "model_name": "Greenstar 8000+", "model_qualifier": "GR8701iW 30 S NG", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 29.6, "final_year_of_manufacture": null, "raw": ["019228", "020051", "0", "2025/Jun/19 15:46", "Bosch Thermotechnology Ltd", "Worcester", "Greenstar 8000+", "GR8701iW 30 S NG", "41-800-27", "2024", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "14.8", "29.6", "A", "", "88.8", "79.8", "", "58.3", "", "2", "", "", "102", "1", "2", "67", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "8305", "", "", "", "", "94", "14", "81", "71.0", "88.4", "98.7", "", "", "", "", "96.8"]} -{"pcdb_id": 19229, "brand_name": "Worcester", "model_name": "Greenstar 8000+", "model_qualifier": "GR8701iW 35 S NG", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 33.7, "final_year_of_manufacture": null, "raw": ["019229", "020051", "0", "2025/Jun/19 12:34", "Bosch Thermotechnology Ltd", "Worcester", "Greenstar 8000+", "GR8701iW 35 S NG", "41-800-28", "2024", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "16.9", "33.7", "A", "", "88.9", "79.9", "", "58.3", "", "2", "", "", "102", "1", "2", "48", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "8305", "", "", "", "", "94", "13", "68", "71.0", "88.3", "98.8", "", "", "", "", "96.8"]} -{"pcdb_id": 19230, "brand_name": "Worcester", "model_name": "Greenstar 8000+", "model_qualifier": "GR8701iW 30 R NG", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 29.6, "final_year_of_manufacture": null, "raw": ["019230", "020051", "0", "2025/Jun/19 13:49", "Bosch Thermotechnology Ltd", "Worcester", "Greenstar 8000+", "GR8701iW 30 R NG", "41-800-29", "2024", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "14.8", "29.6", "A", "", "88.8", "79.8", "", "58.3", "", "2", "", "", "102", "1", "2", "67", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "8305", "", "", "", "", "94", "14", "81", "71.0", "88.4", "98.7", "", "", "", "", "96.8"]} -{"pcdb_id": 19231, "brand_name": "Worcester", "model_name": "Greenstar 8000+", "model_qualifier": "GR8701iW 35 R NG", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 33.7, "final_year_of_manufacture": null, "raw": ["019231", "020051", "0", "2025/Jun/19 14:29", "Bosch Thermotechnology Ltd", "Worcester", "Greenstar 8000+", "GR8701iW 35 R NG", "41-800-30", "2024", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "16.9", "33.7", "A", "", "88.9", "79.9", "", "58.3", "", "2", "", "", "102", "1", "2", "48", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "8305", "", "", "", "", "94", "13", "68", "71.0", "88.3", "98.8", "", "", "", "", "96.8"]} -{"pcdb_id": 19232, "brand_name": "Worcester", "model_name": "Greenstar 8000+", "model_qualifier": "GR8701iW 40 R NG", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 33.7, "final_year_of_manufacture": null, "raw": ["019232", "020051", "0", "2025/Jun/19 15:25", "Bosch Thermotechnology Ltd", "Worcester", "Greenstar 8000+", "GR8701iW 40 R NG", "41-800-31", "2024", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "16.9", "33.7", "A", "", "88.8", "79.8", "", "58.3", "", "2", "", "", "102", "1", "2", "75", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "8305", "", "", "", "", "94", "14", "86", "71.0", "88.1", "98.8", "", "", "", "", "96.8"]} -{"pcdb_id": 19233, "brand_name": "Worcester", "model_name": "Greenstar 8000+", "model_qualifier": "GR8701iW 32 C LPG V2", "winter_efficiency_pct": 90.3, "summer_efficiency_pct": 90.3, "comparative_hot_water_efficiency_pct": 70.9, "output_kw_max": 29.6, "final_year_of_manufacture": null, "raw": ["019233", "020051", "0", "2025/Aug/21 15:31", "Bosch Thermotechnology Ltd", "Worcester", "Greenstar 8000+", "GR8701iW 32 C LPG V2", "47-800-51", "2025", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "14.8", "29.6", "A", "", "90.3", "90.3", "", "70.9", "", "2", "0", "2", "104", "1", "2", "57", "2", "0", "", "", "", "0", "", "", "", "", "2", "7.589", "0.113", "0.0045", "1.43327", "13.465", "0.13", "0.003", "1.42056", "0.00002", "0", "", "", "8305", "", "A", "85", "XL", "95", "12", "71", "71.0", "90.1", "99.6", "", "", "", "", "97.8"]} -{"pcdb_id": 19234, "brand_name": "Worcester", "model_name": "Greenstar 8000+", "model_qualifier": "GR8701iW 32 C NG V2", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 88.1, "comparative_hot_water_efficiency_pct": 70.2, "output_kw_max": 29.6, "final_year_of_manufacture": null, "raw": ["019234", "020051", "0", "2025/Aug/21 15:25", "Bosch Thermotechnology Ltd", "Worcester", "Greenstar 8000+", "GR8701iW 32 C NG V2", "47-800-44", "2025", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "14.8", "29.6", "A", "", "88.9", "88.1", "", "70.2", "", "2", "", "", "104", "1", "2", "57", "2", "0", "", "", "", "0", "", "", "", "", "2", "7.499", "0.113", "0.004", "1.34956", "13.449", "0.128", "0.0025", "1.31483", "0.00002", "0", "", "", "8305", "", "A", "85", "XL", "94", "12", "71", "71.0", "88.1", "99.0", "", "", "", "", "96.9"]} -{"pcdb_id": 19235, "brand_name": "Worcester", "model_name": "Greenstar 8000+ Style", "model_qualifier": "GR8701iW 32 CB NG Style V2", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 88.1, "comparative_hot_water_efficiency_pct": 70.2, "output_kw_max": 29.6, "final_year_of_manufacture": null, "raw": ["019235", "020051", "0", "2025/Aug/21 15:37", "Bosch Thermotechnology Ltd", "Worcester", "Greenstar 8000+ Style", "GR8701iW 32 CB NG Style V2", "47-800-49", "2025", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "14.8", "29.6", "A", "", "88.9", "88.1", "", "70.2", "", "2", "", "", "104", "1", "2", "57", "2", "0", "", "", "", "0", "", "", "", "", "2", "7.499", "0.113", "0.004", "1.34956", "13.449", "0.128", "0.0025", "1.31483", "0.00002", "0", "", "", "8305", "", "A", "85", "XL", "93", "12", "71", "71.0", "88.1", "99.0", "", "", "", "", "96.9"]} -{"pcdb_id": 19236, "brand_name": "Navien", "model_name": "NCB300", "model_qualifier": "NCB300-30K", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 88.2, "comparative_hot_water_efficiency_pct": 70.4, "output_kw_max": 24.0, "final_year_of_manufacture": null, "raw": ["019236", "020178", "0", "2025/Sep/19 10:20", "Navien UK", "Navien", "NCB300", "NCB300-30K", "47-709-17", "2024", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "A", "", "88.1", "88.2", "", "70.4", "", "2", "", "", "104", "1", "2", "39", "3", "0", "", "", "", "0", "", "", "", "", "2", "7.476", "0.125", "0.0245", "1.21005", "13.146", "0.142", "0.002", "1.18378", "0.00023", "0", "", "", "0005", "", "A", "83", "XL", "93", "17", "78", "78.0", "88.2", "96.9", "", "", "", "", "95.3"]} -{"pcdb_id": 19237, "brand_name": "Navien", "model_name": "NCB300", "model_qualifier": "NCB300-30K", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 90.3, "comparative_hot_water_efficiency_pct": 73.3, "output_kw_max": 24.0, "final_year_of_manufacture": null, "raw": ["019237", "020178", "0", "2025/Sep/19 10:32", "Navien UK", "Navien", "NCB300", "NCB300-30K", "47-709-17", "2024", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "A", "", "88.7", "90.3", "", "73.3", "", "2", "0", "2", "104", "1", "2", "39", "3", "0", "", "", "", "0", "", "", "", "", "2", "7.346", "0.111", "0.0065", "1.18048", "13.261", "0.135", "0.0025", "1.17539", "0.00004", "0", "", "", "0005", "", "A", "83", "XL", "93", "17", "78", "78.0", "89.8", "95.7", "", "", "", "", "94.6"]} -{"pcdb_id": 19238, "brand_name": "Navien", "model_name": "NCB500", "model_qualifier": "NCB500-1S+/30K", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 87.4, "comparative_hot_water_efficiency_pct": 69.7, "output_kw_max": 24.0, "final_year_of_manufacture": null, "raw": ["019238", "020178", "0", "2025/Sep/19 11:01", "Navien UK", "Navien", "NCB500", "NCB500-1S+/30K", "47-709-18", "2024", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "A", "", "88.3", "87.4", "", "69.7", "", "2", "", "", "104", "1", "2", "39", "3", "0", "", "", "", "0", "", "", "", "", "2", "7.553", "0.127", "0.002", "1.42558", "13.551", "0.141", "0.0015", "1.32039", "0.00001", "0", "", "", "0005", "", "A", "85", "XL", "93", "17", "78", "78.0", "88.6", "97.4", "", "", "", "", "95.7"]} -{"pcdb_id": 19239, "brand_name": "Navien", "model_name": "NCB500", "model_qualifier": "NCB500-1S+/30K", "winter_efficiency_pct": 89.8, "summer_efficiency_pct": 88.7, "comparative_hot_water_efficiency_pct": 70.3, "output_kw_max": 24.0, "final_year_of_manufacture": null, "raw": ["019239", "020178", "0", "2025/Sep/19 12:18", "Navien UK", "Navien", "NCB500", "NCB500-1S+/30K", "47-709-18", "2024", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "A", "", "89.8", "88.7", "", "70.3", "", "2", "0", "2", "104", "1", "2", "39", "3", "0", "", "", "", "0", "", "", "", "", "2", "7.657", "0.122", "0.002", "1.54088", "13.69", "0.141", "0.001", "1.36976", "0.00001", "0", "", "", "0005", "", "A", "85", "XL", "93", "17", "78", "78.0", "91.1", "97.8", "", "", "", "", "96.5"]} -{"pcdb_id": 19240, "brand_name": "Navien", "model_name": "NCB500", "model_qualifier": "NCB500-15K System", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 15.0, "final_year_of_manufacture": null, "raw": ["019240", "020178", "0", "2025/Sep/19 12:51", "Navien UK", "Navien", "NCB500", "NCB500-15K System", "41-709-09", "2024", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "15", "15", "A", "", "89.0", "80.0", "", "58.4", "", "2", "", "", "102", "1", "2", "36", "3", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "93", "6", "52", "127.0", "87.3", "99.6", "", "", "", "", "97.2"]} -{"pcdb_id": 19241, "brand_name": "Navien", "model_name": "NCB500", "model_qualifier": "NCB500-15K System", "winter_efficiency_pct": 90.2, "summer_efficiency_pct": 81.2, "comparative_hot_water_efficiency_pct": 59.3, "output_kw_max": 15.0, "final_year_of_manufacture": null, "raw": ["019241", "020178", "0", "2025/Sep/19 13:02", "Navien UK", "Navien", "NCB500", "NCB500-15K System", "41-709-09", "2024", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "15", "15", "A", "", "90.2", "81.2", "", "59.3", "", "2", "0", "2", "102", "1", "2", "36", "3", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "93", "6", "52", "127.0", "90.4", "99.2", "", "", "", "", "97.5"]} -{"pcdb_id": 19242, "brand_name": "Navien", "model_name": "NCB500", "model_qualifier": "NCB500-18K System", "winter_efficiency_pct": 89.3, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 18.0, "final_year_of_manufacture": null, "raw": ["019242", "020178", "0", "2025/Sep/19 14:35", "Navien UK", "Navien", "NCB500", "NCB500-18K System", "41-709-10", "2024", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18", "18", "A", "", "89.3", "80.3", "", "58.6", "", "2", "", "", "102", "1", "2", "47", "3", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "93", "11", "69", "127.0", "88.2", "99.9", "", "", "", "", "97.7"]} -{"pcdb_id": 19243, "brand_name": "Navien", "model_name": "NCB500", "model_qualifier": "NCB500-18K System", "winter_efficiency_pct": 90.5, "summer_efficiency_pct": 81.5, "comparative_hot_water_efficiency_pct": 59.5, "output_kw_max": 18.0, "final_year_of_manufacture": null, "raw": ["019243", "020178", "0", "2025/Sep/19 14:44", "Navien UK", "Navien", "NCB500", "NCB500-18K System", "41-709-10", "2024", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "18", "18", "A", "", "90.5", "81.5", "", "59.5", "", "2", "0", "2", "102", "1", "2", "47", "3", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "93", "11", "69", "127.0", "90.4", "100.1", "", "", "", "", "98.3"]} -{"pcdb_id": 19244, "brand_name": "Navien", "model_name": "NCB500", "model_qualifier": "NCB500-24K System", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 24.0, "final_year_of_manufacture": null, "raw": ["019244", "020178", "0", "2025/Sep/19 15:03", "Navien UK", "Navien", "NCB500", "NCB500-24K System", "41-709-11", "2024", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24", "24", "A", "", "88.1", "79.1", "", "57.8", "", "2", "", "", "102", "1", "2", "39", "3", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "93", "17", "78", "78.0", "88.2", "96.9", "", "", "", "", "95.3"]} -{"pcdb_id": 19245, "brand_name": "Navien", "model_name": "NCB500", "model_qualifier": "NCB500-24K System", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 24.0, "final_year_of_manufacture": null, "raw": ["019245", "020178", "0", "2025/Sep/19 15:11", "Navien UK", "Navien", "NCB500", "NCB500-24K System", "41-709-11", "2024", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "24", "24", "A", "", "88.7", "79.7", "", "58.2", "", "2", "0", "2", "102", "1", "2", "39", "3", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "93", "17", "78", "78.0", "89.8", "95.7", "", "", "", "", "94.6"]} -{"pcdb_id": 19246, "brand_name": "Navien", "model_name": "NCB500", "model_qualifier": "NCB500-30K System", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 30.0, "final_year_of_manufacture": null, "raw": ["019246", "020178", "0", "2025/Sep/19 15:24", "Navien UK", "Navien", "NCB500", "NCB500-30K System", "41-709-12", "2024", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "30", "30", "A", "", "88.9", "79.9", "", "58.3", "", "2", "", "", "102", "1", "2", "39", "3", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "93", "19", "82", "127.0", "86.9", "99.5", "", "", "", "", "97.1"]} -{"pcdb_id": 19247, "brand_name": "Navien", "model_name": "NCB500", "model_qualifier": "NCB500-30K System", "winter_efficiency_pct": 90.4, "summer_efficiency_pct": 81.4, "comparative_hot_water_efficiency_pct": 59.4, "output_kw_max": 30.0, "final_year_of_manufacture": null, "raw": ["019247", "020178", "0", "2025/Sep/22 16:59", "Navien UK", "Navien", "NCB500", "NCB500-30K System", "41-709-12", "2024", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "30", "30", "A", "", "90.4", "81.4", "", "59.4", "", "2", "0", "2", "102", "1", "2", "39", "3", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "93", "19", "82", "127.0", "89.6", "100.5", "", "", "", "", "98.4"]} -{"pcdb_id": 19248, "brand_name": "Worcester", "model_name": "GREENSTAR DANESMOOR EXT", "model_qualifier": "12/18 2022+", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 81.4, "comparative_hot_water_efficiency_pct": 59.5, "output_kw_max": 18.0, "final_year_of_manufacture": null, "raw": ["019248", "020051", "0", "2025/Oct/17 16:16", "Bosch Thermotechnology Ltd", "Worcester", "GREENSTAR DANESMOOR EXT", "12/18 2022+", "", "2022", "current", "4", "1", "2", "1", "0", "", "", "2", "2", "1", "13", "18", "A", "", "89.2", "81.4", "", "59.5", "", "2", "", "", "201", "1", "1", "165", "0", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "8303", "", "", "", "", "92", "53", "204", "166.0", "91.7", "97.4", "", "", "", "", "96.4"]} -{"pcdb_id": 19249, "brand_name": "Worcester", "model_name": "GREENSTAR DANESMOOR EXT", "model_qualifier": "18/25 2022+", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 58.8, "output_kw_max": 25.0, "final_year_of_manufacture": null, "raw": ["019249", "020051", "0", "2025/Oct/17 16:17", "Bosch Thermotechnology Ltd", "Worcester", "GREENSTAR DANESMOOR EXT", "18/25 2022+", "", "2022", "current", "4", "1", "2", "1", "0", "", "", "2", "2", "1", "18", "25", "A", "", "88.3", "80.5", "", "58.8", "", "2", "", "", "201", "1", "1", "159", "0", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "8303", "", "", "", "", "92", "49", "197", "159.0", "91.8", "95.2", "", "", "", "", "94.6"]} -{"pcdb_id": 19250, "brand_name": "Worcester", "model_name": "GREENSTAR DANESMOOR EXT", "model_qualifier": "25/32 2022+", "winter_efficiency_pct": 87.7, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 32.0, "final_year_of_manufacture": null, "raw": ["019250", "020051", "0", "2025/Oct/17 16:18", "Bosch Thermotechnology Ltd", "Worcester", "GREENSTAR DANESMOOR EXT", "25/32 2022+", "", "2022", "current", "4", "1", "2", "1", "0", "", "", "2", "2", "1", "25", "32", "A", "", "87.7", "79.9", "", "58.3", "", "2", "", "", "201", "1", "1", "150", "0", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "8303", "", "", "", "", "92", "47", "185", "161.0", "91.5", "93.7", "", "", "", "", "93.3"]} -{"pcdb_id": 19251, "brand_name": "Worcester", "model_name": "GREENSTAR DANESMOOR UTY", "model_qualifier": "12/18 2022+", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 81.4, "comparative_hot_water_efficiency_pct": 59.5, "output_kw_max": 18.0, "final_year_of_manufacture": null, "raw": ["019251", "020051", "0", "2025/Oct/17 16:18", "Bosch Thermotechnology Ltd", "Worcester", "GREENSTAR DANESMOOR UTY", "12/18 2022+", "", "2022", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "13", "18", "A", "", "89.2", "81.4", "", "59.5", "", "2", "", "", "201", "1", "1", "165", "0", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "8303", "", "", "", "", "92", "53", "204", "166.0", "91.7", "97.4", "", "", "", "", "96.4"]} -{"pcdb_id": 19252, "brand_name": "Worcester", "model_name": "GREENSTAR DANESMOOR UTY", "model_qualifier": "18/25 2022+", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 58.8, "output_kw_max": 25.0, "final_year_of_manufacture": null, "raw": ["019252", "020051", "0", "2025/Oct/17 16:20", "Bosch Thermotechnology Ltd", "Worcester", "GREENSTAR DANESMOOR UTY", "18/25 2022+", "", "2022", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "18", "25", "A", "", "88.3", "80.5", "", "58.8", "", "2", "", "", "201", "1", "1", "159", "0", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "8303", "", "", "", "", "92", "49", "197", "159.0", "91.8", "95.2", "", "", "", "", "94.6"]} -{"pcdb_id": 19253, "brand_name": "Worcester", "model_name": "GREENSTAR DANESMOOR UTY", "model_qualifier": "25/32 2022+", "winter_efficiency_pct": 87.7, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 32.0, "final_year_of_manufacture": null, "raw": ["019253", "020051", "0", "2025/Oct/17 16:21", "Bosch Thermotechnology Ltd", "Worcester", "GREENSTAR DANESMOOR UTY", "25/32 2022+", "", "2022", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "25", "32", "A", "", "87.7", "79.9", "", "58.3", "", "2", "", "", "201", "1", "1", "150", "0", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "8303", "", "", "", "", "92", "47", "185", "161.0", "91.5", "93.7", "", "", "", "", "93.3"]} -{"pcdb_id": 19254, "brand_name": "Worcester", "model_name": "GREENSTAR HEATSLAVE II", "model_qualifier": "12/18 2022+", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 83.1, "comparative_hot_water_efficiency_pct": 43.3, "output_kw_max": 18.0, "final_year_of_manufacture": null, "raw": ["019254", "020051", "0", "2025/Oct/27 11:09", "Bosch Thermotechnology Ltd", "Worcester", "GREENSTAR HEATSLAVE II", "12/18 2022+", "", "2022", "current", "4", "1", "1", "2", "0", "", "", "2", "3", "1", "13", "18", "A", "", "89.2", "83.1", "", "43.3", "", "2", "", "", "203", "1", "1", "165", "2", "1", "1", "0", "62", "0", "25", "3", "84", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "8303", "", "B", "66", "XL", "92", "53", "219", "166.0", "91.7", "97.4", "", "", "", "", "96.4"]} -{"pcdb_id": 19255, "brand_name": "Worcester", "model_name": "GREENSTAR HEATSLAVE II", "model_qualifier": "18/25 2022+", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 82.2, "comparative_hot_water_efficiency_pct": 42.7, "output_kw_max": 25.0, "final_year_of_manufacture": null, "raw": ["019255", "020051", "0", "2025/Oct/27 11:10", "Bosch Thermotechnology Ltd", "Worcester", "GREENSTAR HEATSLAVE II", "18/25 2022+", "", "2022", "current", "4", "1", "1", "2", "0", "", "", "2", "3", "1", "18", "25", "A", "", "88.3", "82.2", "", "42.7", "", "2", "", "", "203", "1", "1", "159", "2", "1", "1", "0", "63", "0", "25", "3", "86", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "8303", "", "B", "63", "XL", "92", "49", "212", "159.0", "91.8", "95.2", "", "", "", "", "94.6"]} -{"pcdb_id": 19256, "brand_name": "Worcester", "model_name": "GREENSTAR HEATSLAVE II", "model_qualifier": "25/32 2022+", "winter_efficiency_pct": 87.7, "summer_efficiency_pct": 81.6, "comparative_hot_water_efficiency_pct": 42.2, "output_kw_max": 32.0, "final_year_of_manufacture": null, "raw": ["019256", "020051", "0", "2025/Oct/27 11:11", "Bosch Thermotechnology Ltd", "Worcester", "GREENSTAR HEATSLAVE II", "25/32 2022+", "", "2022", "current", "4", "1", "1", "2", "0", "", "", "2", "3", "1", "25", "32", "A", "", "87.7", "81.6", "", "42.2", "", "2", "", "", "203", "1", "1", "150", "2", "1", "1", "0", "64", "0", "25", "3", "88", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "8303", "", "B", "64", "XL", "92", "47", "200", "161.0", "91.5", "93.7", "", "", "", "", "93.3"]} -{"pcdb_id": 19257, "brand_name": "Worcester", "model_name": "GREENSTAR HEATSLAVE II EXT", "model_qualifier": "12/18 2022+", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 83.1, "comparative_hot_water_efficiency_pct": 43.3, "output_kw_max": 18.0, "final_year_of_manufacture": null, "raw": ["019257", "020051", "0", "2025/Oct/28 10:05", "Bosch Thermotechnology Ltd", "Worcester", "GREENSTAR HEATSLAVE II EXT", "12/18 2022+", "", "2022", "current", "4", "1", "2", "2", "0", "", "", "2", "2", "2", "13", "18", "A", "", "89.2", "83.1", "", "43.3", "", "2", "", "", "203", "1", "1", "165", "2", "1", "1", "0", "62", "0", "25", "3", "84", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "8303", "", "B", "66", "XL", "92", "53", "219", "166.0", "91.7", "97.4", "", "", "", "", "96.4"]} -{"pcdb_id": 19258, "brand_name": "Worcester", "model_name": "GREENSTAR HEATSLAVE II EXT", "model_qualifier": "18/25 2022+", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 82.2, "comparative_hot_water_efficiency_pct": 42.7, "output_kw_max": 25.0, "final_year_of_manufacture": null, "raw": ["019258", "020051", "0", "2025/Oct/28 10:27", "Bosch Thermotechnology Ltd", "Worcester", "GREENSTAR HEATSLAVE II EXT", "18/25 2022+", "", "2022", "current", "4", "1", "2", "2", "0", "", "", "2", "2", "2", "18", "25", "A", "", "88.3", "82.2", "", "42.7", "", "2", "", "", "203", "1", "1", "159", "2", "1", "1", "0", "63", "0", "25", "3", "86", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "8303", "", "B", "63", "XL", "92", "49", "212", "159.0", "91.8", "95.2", "", "", "", "", "94.6"]} -{"pcdb_id": 19259, "brand_name": "Worcester", "model_name": "GREENSTAR HEATSLAVE II EXT", "model_qualifier": "25/32 2022+", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 83.0, "comparative_hot_water_efficiency_pct": 42.9, "output_kw_max": 32.0, "final_year_of_manufacture": null, "raw": ["019259", "020051", "0", "2025/Oct/28 10:35", "Bosch Thermotechnology Ltd", "Worcester", "GREENSTAR HEATSLAVE II EXT", "25/32 2022+", "", "2022", "current", "4", "1", "2", "2", "0", "", "", "2", "2", "2", "25", "32", "A", "", "89.1", "83.0", "", "42.9", "", "2", "", "", "203", "1", "1", "150", "2", "1", "1", "0", "64", "0", "25", "3", "88", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "8303", "", "B", "64", "XL", "92", "47", "200", "161.0", "91.5", "97.3", "", "", "", "", "96.2"]} -{"pcdb_id": 19260, "brand_name": "Worcester", "model_name": "GREENSTAR DANESMOOR UTY", "model_qualifier": "32/50 2022+", "winter_efficiency_pct": 87.7, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 50.0, "final_year_of_manufacture": null, "raw": ["019260", "020051", "0", "2025/Oct/17 16:32", "Bosch Thermotechnology Ltd", "Worcester", "GREENSTAR DANESMOOR UTY", "32/50 2022+", "", "2022", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "32", "50", "A", "", "87.7", "79.9", "", "58.3", "", "2", "", "", "201", "1", "1", "198", "0", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "8303", "", "", "", "", "91", "62", "245", "258.0", "91.3", "93.8", "", "", "", "", "93.3"]} -{"pcdb_id": 19261, "brand_name": "Worcester", "model_name": "GREENSTAR DANESMOOR SYS EXT", "model_qualifier": "12/18 2022+", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 81.4, "comparative_hot_water_efficiency_pct": 59.5, "output_kw_max": 18.0, "final_year_of_manufacture": null, "raw": ["019261", "020051", "0", "2025/Oct/17 16:33", "Bosch Thermotechnology Ltd", "Worcester", "GREENSTAR DANESMOOR SYS EXT", "12/18 2022+", "", "2022", "current", "4", "1", "2", "1", "0", "", "", "2", "2", "1", "13", "18", "A", "", "89.2", "81.4", "", "59.5", "", "2", "", "", "201", "1", "1", "165", "0", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "8303", "", "", "", "", "92", "53", "204", "166.0", "91.7", "97.4", "", "", "", "", "96.4"]} -{"pcdb_id": 19262, "brand_name": "Worcester", "model_name": "GREENSTAR DANESMOOR SYS EXT", "model_qualifier": "18/25 2022+", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 58.8, "output_kw_max": 25.0, "final_year_of_manufacture": null, "raw": ["019262", "020051", "0", "2025/Oct/17 16:34", "Bosch Thermotechnology Ltd", "Worcester", "GREENSTAR DANESMOOR SYS EXT", "18/25 2022+", "", "2022", "current", "4", "1", "2", "1", "0", "", "", "2", "2", "1", "18", "25", "A", "", "88.3", "80.5", "", "58.8", "", "2", "", "", "201", "1", "1", "159", "0", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "8303", "", "", "", "", "92", "49", "197", "159.0", "91.8", "95.2", "", "", "", "", "94.6"]} -{"pcdb_id": 19263, "brand_name": "Worcester", "model_name": "GREENSTAR DANESMOOR SYS EXT", "model_qualifier": "25/32 2022+", "winter_efficiency_pct": 87.7, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 32.0, "final_year_of_manufacture": null, "raw": ["019263", "020051", "0", "2025/Oct/17 16:34", "Bosch Thermotechnology Ltd", "Worcester", "GREENSTAR DANESMOOR SYS EXT", "25/32 2022+", "", "2022", "current", "4", "1", "2", "1", "0", "", "", "2", "2", "1", "25", "32", "A", "", "87.7", "79.9", "", "58.3", "", "2", "", "", "201", "1", "1", "150", "0", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "8303", "", "", "", "", "92", "47", "185", "161.0", "91.5", "93.7", "", "", "", "", "93.3"]} -{"pcdb_id": 19264, "brand_name": "Worcester", "model_name": "GREENSTAR DANESMOOR", "model_qualifier": "12/18 2022+", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 81.4, "comparative_hot_water_efficiency_pct": 59.5, "output_kw_max": 18.0, "final_year_of_manufacture": null, "raw": ["019264", "020051", "0", "2025/Oct/17 16:35", "Bosch Thermotechnology Ltd", "Worcester", "GREENSTAR DANESMOOR", "12/18 2022+", "", "2022", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "13", "18", "A", "", "89.2", "81.4", "", "59.5", "", "2", "", "", "201", "1", "1", "165", "0", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "8303", "", "", "", "", "92", "53", "204", "166.0", "91.7", "97.4", "", "", "", "", "96.4"]} -{"pcdb_id": 19265, "brand_name": "Worcester", "model_name": "GREENSTAR DANESMOOR", "model_qualifier": "18/25 2022+", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 58.8, "output_kw_max": 25.0, "final_year_of_manufacture": null, "raw": ["019265", "020051", "0", "2025/Oct/17 16:36", "Bosch Thermotechnology Ltd", "Worcester", "GREENSTAR DANESMOOR", "18/25 2022+", "", "2022", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "18", "25", "A", "", "88.3", "80.5", "", "58.8", "", "2", "", "", "201", "1", "1", "159", "0", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "8303", "", "", "", "", "92", "49", "197", "159.0", "91.8", "95.2", "", "", "", "", "94.6"]} -{"pcdb_id": 19266, "brand_name": "Worcester", "model_name": "GREENSTAR DANESMOOR", "model_qualifier": "25/32 2022+", "winter_efficiency_pct": 87.7, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 32.0, "final_year_of_manufacture": null, "raw": ["019266", "020051", "0", "2025/Oct/17 16:36", "Bosch Thermotechnology Ltd", "Worcester", "GREENSTAR DANESMOOR", "25/32 2022+", "", "2022", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "25", "32", "A", "", "87.7", "79.9", "", "58.3", "", "2", "", "", "201", "1", "1", "150", "0", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "8303", "", "", "", "", "92", "47", "185", "161.0", "91.5", "93.7", "", "", "", "", "93.3"]} -{"pcdb_id": 19267, "brand_name": "Worcester", "model_name": "Greenstar 8000 F", "model_qualifier": "GR8700iF 35 C NG", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 86.7, "comparative_hot_water_efficiency_pct": 68.7, "output_kw_max": 33.8, "final_year_of_manufacture": null, "raw": ["019267", "020051", "0", "2025/Nov/27 09:53", "Bosch Thermotechnology Ltd", "Worcester", "Greenstar 8000 F", "GR8700iF 35 C NG", "47-800-56", "2025", "current", "1", "1", "1", "2", "0", "", "", "2", "2", "2", "33.8", "33.8", "A", "", "88.2", "86.7", "", "68.7", "", "2", "", "", "104", "1", "2", "50", "4", "0", "", "", "", "0", "", "", "", "", "1", "7.67", "0.171", "0.0075", "1.48868", "", "", "", "", "", "0", "", "", "8305", "", "A", "82", "XL", "92", "14", "83", "134.0", "87.9", "97.3", "", "", "", "", "95.5"]} -{"pcdb_id": 19268, "brand_name": "Worcester", "model_name": "Greenstar 8000 F", "model_qualifier": "GR8700iF 35 C LPG", "winter_efficiency_pct": 89.8, "summer_efficiency_pct": 88.4, "comparative_hot_water_efficiency_pct": 67.7, "output_kw_max": 33.8, "final_year_of_manufacture": null, "raw": ["019268", "020051", "0", "2025/Nov/27 10:13", "Bosch Thermotechnology Ltd", "Worcester", "Greenstar 8000 F", "GR8700iF 35 C LPG", "47-800-57", "2025", "current", "2", "1", "1", "2", "0", "", "", "2", "2", "2", "33.8", "33.8", "A", "", "89.8", "88.4", "", "67.7", "", "2", "0", "2", "104", "1", "2", "49", "4", "0", "", "", "", "0", "", "", "", "", "1", "7.955", "0.171", "0.0095", "1.73552", "", "", "", "", "", "0", "", "", "8305", "", "A", "83", "XL", "94", "15", "85", "134.0", "89.3", "98.5", "", "", "", "", "96.8"]} -{"pcdb_id": 19269, "brand_name": "Worcester", "model_name": "Greenstar 8000 F", "model_qualifier": "GR8700iF 50 C NG", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 86.3, "comparative_hot_water_efficiency_pct": 66.9, "output_kw_max": 47.8, "final_year_of_manufacture": null, "raw": ["019269", "020051", "0", "2025/Nov/27 10:46", "Bosch Thermotechnology Ltd", "Worcester", "Greenstar 8000 F", "GR8700iF 50 C NG", "47-800-58", "2025", "current", "1", "1", "1", "2", "0", "", "", "2", "2", "2", "47.8", "47.8", "A", "", "88.2", "86.3", "", "66.9", "", "2", "", "", "104", "1", "2", "86", "4", "0", "", "", "", "0", "", "", "", "", "1", "7.876", "0.169", "0.0065", "1.66434", "", "", "", "", "", "0", "", "", "8305", "", "A", "82", "XL", "93", "15", "106", "147.0", "86.9", "97.7", "", "", "", "", "95.6"]} -{"pcdb_id": 19270, "brand_name": "Worcester", "model_name": "Greenstar 8000 F", "model_qualifier": "GR8700iF 50 C LPG", "winter_efficiency_pct": 89.9, "summer_efficiency_pct": 88.7, "comparative_hot_water_efficiency_pct": 67.5, "output_kw_max": 47.8, "final_year_of_manufacture": null, "raw": ["019270", "020051", "0", "2025/Nov/27 11:07", "Bosch Thermotechnology Ltd", "Worcester", "Greenstar 8000 F", "GR8700iF 50 C LPG", "47-800-59", "2025", "current", "2", "1", "1", "2", "0", "", "", "2", "2", "2", "47.8", "47.8", "A", "", "89.9", "88.7", "", "67.5", "", "2", "0", "2", "104", "1", "2", "82", "4", "0", "", "", "", "0", "", "", "", "", "1", "7.972", "0.168", "0.0085", "1.78375", "", "", "", "", "", "0", "", "", "8305", "", "A", "83", "XL", "94", "16", "106", "147.0", "90.3", "98.5", "", "", "", "", "97.0"]} -{"pcdb_id": 19271, "brand_name": "Worcester", "model_name": "Greenstar 8000 F", "model_qualifier": "GR8700iF 35 R NG", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 33.8, "final_year_of_manufacture": null, "raw": ["019271", "020051", "0", "2025/Nov/27 11:27", "Bosch Thermotechnology Ltd", "Worcester", "Greenstar 8000 F", "GR8700iF 35 R NG", "41-800-41", "2025", "current", "1", "1", "1", "1", "0", "", "", "2", "2", "2", "33.8", "33.8", "A", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "51", "4", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "8305", "", "", "", "", "93", "14", "84", "90.0", "87.4", "97.9", "", "", "", "", "95.9"]} -{"pcdb_id": 19272, "brand_name": "Worcester", "model_name": "Greenstar 8000 F", "model_qualifier": "GR8700iF 35 R LPG", "winter_efficiency_pct": 89.9, "summer_efficiency_pct": 80.9, "comparative_hot_water_efficiency_pct": 59.1, "output_kw_max": 33.8, "final_year_of_manufacture": null, "raw": ["019272", "020051", "0", "2025/Nov/27 11:37", "Bosch Thermotechnology Ltd", "Worcester", "Greenstar 8000 F", "GR8700iF 35 R LPG", "41-800-42", "2025", "current", "2", "1", "1", "1", "0", "", "", "2", "2", "2", "33.8", "33.8", "A", "", "89.9", "80.9", "", "59.1", "", "2", "0", "2", "102", "1", "2", "50", "4", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "8305", "", "", "", "", "94", "13", "81", "90.0", "90.3", "98.6", "", "", "", "", "97.0"]} -{"pcdb_id": 19273, "brand_name": "Worcester", "model_name": "Greenstar 8000 F", "model_qualifier": "GR8700iF 50 R NG", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 47.8, "final_year_of_manufacture": null, "raw": ["019273", "020051", "0", "2025/Nov/27 13:24", "Bosch Thermotechnology Ltd", "Worcester", "Greenstar 8000 F", "GR8700iF 50 R NG", "41-800-43", "2025", "current", "1", "1", "1", "1", "0", "", "", "2", "2", "2", "47.8", "47.8", "A", "", "88.2", "79.2", "", "57.9", "", "2", "", "", "102", "1", "2", "86", "4", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "8305", "", "", "", "", "93", "15", "106", "98.0", "87.8", "97.4", "", "", "", "", "95.6"]} -{"pcdb_id": 19274, "brand_name": "Worcester", "model_name": "Greenstar 8000 F", "model_qualifier": "GR8700iF 50 R LPG", "winter_efficiency_pct": 90.0, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 59.2, "output_kw_max": 47.8, "final_year_of_manufacture": null, "raw": ["019274", "020051", "0", "2025/Nov/27 13:50", "Bosch Thermotechnology Ltd", "Worcester", "Greenstar 8000 F", "GR8700iF 50 R LPG", "41-800-44", "2025", "current", "2", "1", "1", "1", "0", "", "", "2", "2", "2", "47.8", "47.8", "A", "", "90.0", "81.0", "", "59.2", "", "2", "0", "2", "102", "1", "2", "82", "4", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "8305", "", "", "", "", "94", "15", "104", "98.0", "91.5", "98.3", "", "", "", "", "97.0"]} -{"pcdb_id": 18861, "brand_name": "Glow-worm", "model_name": "Compact", "model_qualifier": "24c-AS/1 (H-GB)", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 86.6, "comparative_hot_water_efficiency_pct": 73.6, "output_kw_max": 18.3, "final_year_of_manufacture": null, "raw": ["018861", "000207", "0", "2020/Jan/27 09:16", "Glow-worm", "Glow-worm", "Compact", "24c-AS/1 (H-GB)", "", "2019", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "18.3", "18.3", "", "", "88.0", "86.6", "", "73.6", "", "2", "", "", "104", "1", "2", " 27", " 2", "0", "", "", "", "0", "", "", "", "", "1", "7.151", "0.067", "0.0008", "1.02612", "", "", "", "", "", "", "", "", "0085", "", "", "", "", "", "", "", "", "87.8", "96.9", "", "", "", "", "95.1"]} -{"pcdb_id": 18862, "brand_name": "Glow-worm", "model_name": "Compact", "model_qualifier": "28c-AS/1 (H-GB)", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 86.6, "comparative_hot_water_efficiency_pct": 67.9, "output_kw_max": 23.9, "final_year_of_manufacture": null, "raw": ["018862", "000207", "0", "2020/Jan/27 09:16", "Glow-worm", "Glow-worm", "Compact", "28c-AS/1 (H-GB)", "", "2019", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "23.9", "23.9", "", "", "88.3", "86.6", "", "67.9", "", "2", "", "", "104", "1", "2", " 35", " 2", "0", "", "", "", "0", "", "", "", "", "1", "7.759", "0.07", "0.0203", "1.49449", "", "", "", "", "", "", "", "", "0085", "", "", "", "", "", "", "", "", "87.8", "97.7", "", "", "", "", "95.8"]} -{"pcdb_id": 18874, "brand_name": "Vaillant", "model_name": "ecoTEC plus 435", "model_qualifier": "VU 356/6-5 OVZ (H-GB)", "winter_efficiency_pct": 84.0, "summer_efficiency_pct": 74.0, "comparative_hot_water_efficiency_pct": null, "output_kw_max": 35.0, "final_year_of_manufacture": null, "raw": ["018874", "000031", "0", "2022/Oct/27 12:15", "Vaillant", "Vaillant", "ecoTEC plus 435", "VU 356/6-5 OVZ (H-GB)", "41-044-76", "2018", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "35", "35", "", "", "84.0", "74.0", "", "", "", "2", "", "", "102", "1", "2", "", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0045", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} -{"pcdb_id": 690201, "brand_name": "Generic Boiler", "model_name": "Hybrid Combi Boiler", "model_qualifier": "", "winter_efficiency_pct": 89.9, "summer_efficiency_pct": 86.7, "comparative_hot_water_efficiency_pct": null, "output_kw_max": null, "final_year_of_manufacture": null, "raw": ["690201", "300903", "0", "2023/Jan/30 08:51", "SAP Generic Products", "Generic Boiler", "Hybrid Combi Boiler", "", "", "2020", "current", "1", "0", "0", "2", "0", "", "", "2", "2", "2", "", "", "", "", "89.9", "86.7", "", "", "", "0", "", "", "0", "1", "2", "", "", "0", "", "", "", "0", "", "", "", "", "1", "7.122", "0.114", "0.004335", "1.00577248", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.8", "97.8", "", "", "", "", ""]} -{"pcdb_id": 690001, "brand_name": "Illustrative Boiler", "model_name": "Regular", "model_qualifier": "Gas condensing", "winter_efficiency_pct": 89.9, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 53.3, "output_kw_max": 11.82, "final_year_of_manufacture": null, "raw": ["690001", "300900", "1", "2011/Sep/16 21:51", "SAP Illustrative Products", "Illustrative Boiler", "Regular", "Gas condensing", "", "2011", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "11.82", "11.82", "", "88.9", "89.9", "79.2", "0", "53.3", "", "2", "", "", "102", "1", "2", "80", "1.07", "0", "", "", "", "0.0", "", "0", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", ""]} -{"pcdb_id": 690002, "brand_name": "Illustrative Boiler", "model_name": "Instantaneous combi", "model_qualifier": "Gas condensing", "winter_efficiency_pct": 89.8, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 62.2, "output_kw_max": 11.82, "final_year_of_manufacture": null, "raw": ["690002", "300900", "1", "2011/Sep/16 21:51", "SAP Illustrative Products", "Illustrative Boiler", "Instantaneous combi", "Gas condensing", "", "2011", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "11.82", "11.82", "", "88.9", "89.8", "79.7", "0", "62.2", "", "2", "", "", "104", "1", "2", "80", "1.07", "0", "", "", "", "0.0", "", "0", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "0", "0005", "", "", "", "", ""]} -{"pcdb_id": 690003, "brand_name": "Illustrative Boiler", "model_name": "Storage combi", "model_qualifier": "Gas condensing", "winter_efficiency_pct": 90.1, "summer_efficiency_pct": 81.4, "comparative_hot_water_efficiency_pct": 66.0, "output_kw_max": 11.62, "final_year_of_manufacture": null, "raw": ["690003", "300900", "1", "2011/Sep/16 21:31", "SAP Illustrative Products", "Illustrative Boiler", "Storage combi", "Gas condensing", "", "2011", "current", "1", "1", "1", "2", "0", "", "", "2", "2", "2", "11.62", "11.62", "", "89.4", "90.1", "81.4", "0", "66.0", "", "2", "", "", "106", "1", "2", "", "", "1", "1", "0", "95", "0.0", "55", "2", "75", "60", "0", "", "", "", "", "", "", "", "", "", "", "", "0", "0005", "", "", "", "", ""]} -{"pcdb_id": 690004, "brand_name": "Illustrative Boiler", "model_name": "Regular", "model_qualifier": "LPG condensing", "winter_efficiency_pct": 91.1, "summer_efficiency_pct": 80.4, "comparative_hot_water_efficiency_pct": 51.4, "output_kw_max": 11.82, "final_year_of_manufacture": null, "raw": ["690004", "300900", "1", "2011/Sep/16 21:51", "SAP Illustrative Products", "Illustrative Boiler", "Regular", "LPG condensing", "", "2011", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "11.82", "11.82", "", "90.1", "91.1", "80.4", "0", "51.4", "", "2", "", "", "102", "1", "2", "80", "1.07", "0", "", "", "", "0.0", "", "0", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", ""]} -{"pcdb_id": 690005, "brand_name": "Illustrative Boiler", "model_name": "Instantaneous combi", "model_qualifier": "LPG condensing", "winter_efficiency_pct": 90.5, "summer_efficiency_pct": 80.9, "comparative_hot_water_efficiency_pct": 63.2, "output_kw_max": 11.82, "final_year_of_manufacture": null, "raw": ["690005", "300900", "1", "2011/Sep/16 21:51", "SAP Illustrative Products", "Illustrative Boiler", "Instantaneous combi", "LPG condensing", "", "2011", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "11.82", "11.82", "", "90.0", "90.5", "80.9", "0", "63.2", "", "2", "", "", "104", "1", "2", "80", "1.07", "0", "", "", "", "0.0", "", "0", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "0", "0005", "", "", "", "", ""]} -{"pcdb_id": 690006, "brand_name": "Illustrative Boiler", "model_name": "Regular", "model_qualifier": "Oil condensing", "winter_efficiency_pct": 92.0, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 54.0, "output_kw_max": 12.82, "final_year_of_manufacture": null, "raw": ["690006", "300900", "1", "2011/Sep/16 21:51", "SAP Illustrative Products", "Illustrative Boiler", "Regular", "Oil condensing", "", "2011", "current", "4", "2", "1", "1", "0", "", "", "2", "2", "2", "12.82", "12.82", "", "90.9", "92.0", "80.3", "0", "54.0", "", "2", "", "", "201", "1", "1", "80", "1.07", "0", "", "", "", "0.0", "", "0", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", ""]} -{"pcdb_id": 690007, "brand_name": "Illustrative Boiler", "model_name": "Storage combi", "model_qualifier": "Oil condensing", "winter_efficiency_pct": 90.1, "summer_efficiency_pct": 82.1, "comparative_hot_water_efficiency_pct": 62.5, "output_kw_max": 12.82, "final_year_of_manufacture": null, "raw": ["690007", "300900", "1", "2011/Sep/16 21:02", "SAP Illustrative Products", "Illustrative Boiler", "Storage combi", "Oil condensing", "", "2011", "current", "4", "1", "2", "2", "0", "", "", "2", "2", "2", "12.82", "12.82", "", "89.3", "90.1", "82.1", "0", "62.5", "", "2", "", "", "203", "1", "1", "240", "", "1", "1", "0", "69", "0.0", "25", "3", "82", "", "0", "", "", "", "", "", "", "", "", "", "", "", "0", "0005", "", "", "", "", ""]} +{"pcdb_id": 98, "brand_name": "Baxi Heating", "model_name": "Wm", "model_qualifier": "20/3rs", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 5.86, "final_year_of_manufacture": 1990, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000098", "000005", "0", "2010/Sep/13 17:03", "Baxi Heating", "Baxi Heating", "Wm", "20/3rs", "4107739", "", "1990", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "5.86", "5.86", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 99, "brand_name": "Baxi Heating", "model_name": "Wm", "model_qualifier": "281rs", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 8.2, "final_year_of_manufacture": 1984, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000099", "000005", "0", "2010/Sep/13 17:03", "Baxi Heating", "Baxi Heating", "Wm", "281rs", "4107707", "", "1984", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "8.2", "8.2", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 100, "brand_name": "Baxi Heating", "model_name": "Wm", "model_qualifier": "282rs", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 8.2, "final_year_of_manufacture": 1984, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000100", "000005", "0", "2010/Sep/13 17:03", "Baxi Heating", "Baxi Heating", "Wm", "282rs", "4107731", "", "1984", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "8.2", "8.2", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 102, "brand_name": "Baxi Heating", "model_name": "Wm", "model_qualifier": "38/3", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 11.14, "final_year_of_manufacture": 1990, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000102", "000005", "0", "2010/Sep/13 17:03", "Baxi Heating", "Baxi Heating", "Wm", "38/3", "4107735", "", "1990", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "11.14", "11.14", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 103, "brand_name": "Baxi Heating", "model_name": "Wm", "model_qualifier": "381rs", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 11.14, "final_year_of_manufacture": 1984, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000103", "000005", "0", "2010/Sep/13 17:03", "Baxi Heating", "Baxi Heating", "Wm", "381rs", "4107705", "", "1984", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "11.14", "11.14", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 104, "brand_name": "Baxi Heating", "model_name": "Wm", "model_qualifier": "382rs", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 11.14, "final_year_of_manufacture": 1984, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000104", "000005", "0", "2010/Sep/13 17:03", "Baxi Heating", "Baxi Heating", "Wm", "382rs", "4107732", "", "1984", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "11.14", "11.14", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 105, "brand_name": "Baxi Heating", "model_name": "Wm", "model_qualifier": "40/3of", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 11.73, "final_year_of_manufacture": 1990, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000105", "000005", "0", "2010/Sep/13 17:03", "Baxi Heating", "Baxi Heating", "Wm", "40/3of", "4107738", "", "1990", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "11.73", "11.73", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 106, "brand_name": "Baxi Heating", "model_name": "Wm", "model_qualifier": "401of", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 11.73, "final_year_of_manufacture": 1981, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000106", "000005", "0", "2010/Sep/13 17:03", "Baxi Heating", "Baxi Heating", "Wm", "401of", "4107704", "", "1981", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "11.73", "11.73", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 108, "brand_name": "Baxi Heating", "model_name": "Wm", "model_qualifier": "402of", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 11.73, "final_year_of_manufacture": 1984, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000108", "000005", "0", "2010/Sep/13 17:03", "Baxi Heating", "Baxi Heating", "Wm", "402of", "4107709", "", "1984", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "11.73", "11.73", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 109, "brand_name": "Baxi Heating", "model_name": "Wm", "model_qualifier": "51/3", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 14.95, "final_year_of_manufacture": 1990, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000109", "000005", "0", "2010/Sep/13 17:03", "Baxi Heating", "Baxi Heating", "Wm", "51/3", "4107734", "", "1990", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "14.95", "14.95", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 110, "brand_name": "Baxi Heating", "model_name": "Wm", "model_qualifier": "511rs", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 15.0, "final_year_of_manufacture": 1984, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000110", "000005", "0", "2010/Sep/13 17:03", "Baxi Heating", "Baxi Heating", "Wm", "511rs", "4107708", "", "1984", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "15", "15", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 111, "brand_name": "Baxi Heating", "model_name": "Wm", "model_qualifier": "512rs", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 15.0, "final_year_of_manufacture": 1984, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000111", "000005", "0", "2010/Sep/13 17:03", "Baxi Heating", "Baxi Heating", "Wm", "512rs", "4107733", "", "1984", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "15", "15", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 113, "brand_name": "Baxi Heating", "model_name": "Wm", "model_qualifier": "532rs", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 15.5, "final_year_of_manufacture": 1981, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000113", "000005", "0", "2010/Sep/13 17:03", "Baxi Heating", "Baxi Heating", "Wm", "532rs", "4107706", "", "1981", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "15.5", "15.5", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 114, "brand_name": "Baxi Heating", "model_name": "Wm", "model_qualifier": "55/3of", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 16.1, "final_year_of_manufacture": 1990, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000114", "000005", "0", "2010/Sep/13 17:03", "Baxi Heating", "Baxi Heating", "Wm", "55/3of", "4107737", "", "1990", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "16.1", "16.1", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 115, "brand_name": "Baxi Heating", "model_name": "Wm", "model_qualifier": "551of", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 16.11, "final_year_of_manufacture": 1981, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000115", "000005", "0", "2010/Sep/13 17:03", "Baxi Heating", "Baxi Heating", "Wm", "551of", "4107702", "", "1981", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "16.11", "16.11", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 116, "brand_name": "Baxi Heating", "model_name": "Wm", "model_qualifier": "552of", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 16.12, "final_year_of_manufacture": 1984, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000116", "000005", "0", "2010/Sep/13 17:03", "Baxi Heating", "Baxi Heating", "Wm", "552of", "4107710", "", "1984", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "16.12", "16.12", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 117, "brand_name": "Baxi Heating", "model_name": "Wm", "model_qualifier": "60/3rs", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 17.38, "final_year_of_manufacture": 1990, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000117", "000005", "0", "2010/Sep/13 17:03", "Baxi Heating", "Baxi Heating", "Wm", "60/3rs", "4107740", "", "1990", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "17.38", "17.38", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 126, "brand_name": "Broag Remeha", "model_name": "W40M Eco", "model_qualifier": "", "winter_efficiency_pct": 91.0, "summer_efficiency_pct": 74.0, "comparative_hot_water_efficiency_pct": 53.7, "output_kw_max": null, "final_year_of_manufacture": 1999, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000126", "000006", "0", "2010/Sep/13 17:03", "Broag", "Broag Remeha", "W40M Eco", "", "", "", "1999", "1", "0", "0", "1", "0", "", "", "2", "2", "2", "", "", "", "", "91.0", "74.0", "", "53.7", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0001", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 127, "brand_name": "Broag Remeha", "model_name": "W60M Eco", "model_qualifier": "", "winter_efficiency_pct": 91.0, "summer_efficiency_pct": 74.0, "comparative_hot_water_efficiency_pct": 53.7, "output_kw_max": null, "final_year_of_manufacture": 1999, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000127", "000006", "0", "2010/Sep/13 17:03", "Broag", "Broag Remeha", "W60M Eco", "", "", "", "1999", "1", "0", "0", "1", "0", "", "", "2", "2", "2", "", "", "", "", "91.0", "74.0", "", "53.7", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0001", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 130, "brand_name": "Burco Maxol", "model_name": "Microturbo", "model_qualifier": "40 SRF & 40 MDF", "winter_efficiency_pct": 69.0, "summer_efficiency_pct": 59.0, "comparative_hot_water_efficiency_pct": 43.0, "output_kw_max": 11.7, "final_year_of_manufacture": 1998, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000130", "000007", "0", "2010/Sep/13 17:03", "Burco Maxol", "Burco Maxol", "Microturbo", "40 SRF & 40 MDF", "4120219", "", "1998", "1", "0", "0", "1", "0", "", "", "1", "2", "2", "11.7", "11.7", "", "", "69.0", "59.0", "", "43.0", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 131, "brand_name": "Burco Maxol", "model_name": "Microturbo", "model_qualifier": "50 SRF & 50 MDF", "winter_efficiency_pct": 69.0, "summer_efficiency_pct": 59.0, "comparative_hot_water_efficiency_pct": 43.0, "output_kw_max": 14.6, "final_year_of_manufacture": 1998, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000131", "000007", "0", "2010/Sep/13 17:03", "Burco Maxol", "Burco Maxol", "Microturbo", "50 SRF & 50 MDF", "4120219", "", "1998", "1", "0", "0", "1", "0", "", "", "1", "2", "2", "14.6", "14.6", "", "", "69.0", "59.0", "", "43.0", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 260, "brand_name": "Caradon Ideal", "model_name": "Mexico Slimline", "model_qualifier": "cf40", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 11.72, "final_year_of_manufacture": 1988, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000260", "000008", "0", "2010/Sep/13 17:03", "Caradon Ideal", "Caradon Ideal", "Mexico Slimline", "cf40", "4140716", "", "1988", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "11.72", "11.72", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 262, "brand_name": "Caradon Ideal", "model_name": "Mexico Slimline", "model_qualifier": "cf55", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 16.12, "final_year_of_manufacture": 1988, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000262", "000008", "0", "2010/Sep/13 17:03", "Caradon Ideal", "Caradon Ideal", "Mexico Slimline", "cf55", "4140718", "", "1988", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "16.12", "16.12", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 264, "brand_name": "Caradon Ideal", "model_name": "Mexico Slimline", "model_qualifier": "rs40", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 11.72, "final_year_of_manufacture": 1988, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000264", "000008", "0", "2010/Sep/13 17:03", "Caradon Ideal", "Caradon Ideal", "Mexico Slimline", "rs40", "4140715", "", "1988", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "11.72", "11.72", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 266, "brand_name": "Caradon Ideal", "model_name": "Mexico Slimline", "model_qualifier": "rs55", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 16.12, "final_year_of_manufacture": 1988, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000266", "000008", "0", "2010/Sep/13 17:03", "Caradon Ideal", "Caradon Ideal", "Mexico Slimline", "rs55", "4140717", "", "1988", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "16.12", "16.12", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 268, "brand_name": "Caradon Ideal", "model_name": "Mexico Slimline 2", "model_qualifier": "cf40", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 11.72, "final_year_of_manufacture": 1988, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000268", "000008", "0", "2010/Sep/13 17:03", "Caradon Ideal", "Caradon Ideal", "Mexico Slimline 2", "cf40", "4142108", "", "1988", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "11.72", "11.72", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 269, "brand_name": "Caradon Ideal", "model_name": "Mexico Slimline 2", "model_qualifier": "cf55", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 16.12, "final_year_of_manufacture": 1988, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000269", "000008", "0", "2010/Sep/13 17:03", "Caradon Ideal", "Caradon Ideal", "Mexico Slimline 2", "cf55", "4142109", "", "1988", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "16.12", "16.12", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 270, "brand_name": "Caradon Ideal", "model_name": "Mexico Slimline 2", "model_qualifier": "rs40", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 11.72, "final_year_of_manufacture": 1988, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000270", "000008", "0", "2010/Sep/13 17:03", "Caradon Ideal", "Caradon Ideal", "Mexico Slimline 2", "rs40", "4142110", "", "1988", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "11.72", "11.72", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 271, "brand_name": "Caradon Ideal", "model_name": "Mexico Slimline 2", "model_qualifier": "rs55", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 16.12, "final_year_of_manufacture": 1988, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000271", "000008", "0", "2010/Sep/13 17:03", "Caradon Ideal", "Caradon Ideal", "Mexico Slimline 2", "rs55", "4142111", "", "1988", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "16.12", "16.12", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 272, "brand_name": "Caradon Ideal", "model_name": "Mexico Super", "model_qualifier": "cf100", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 29.3, "final_year_of_manufacture": 1988, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000272", "000008", "0", "2010/Sep/13 17:03", "Caradon Ideal", "Caradon Ideal", "Mexico Super", "cf100", "4140746", "", "1988", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "29.3", "29.3", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 273, "brand_name": "Caradon Ideal", "model_name": "Mexico Super", "model_qualifier": "cf125", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 36.64, "final_year_of_manufacture": 1988, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000273", "000008", "0", "2010/Sep/13 17:03", "Caradon Ideal", "Caradon Ideal", "Mexico Super", "cf125", "4140748", "", "1988", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "36.64", "36.64", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 275, "brand_name": "Caradon Ideal", "model_name": "Mexico Super", "model_qualifier": "cf30/40", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 11.72, "final_year_of_manufacture": 1988, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000275", "000008", "0", "2010/Sep/13 17:03", "Caradon Ideal", "Caradon Ideal", "Mexico Super", "cf30/40", "4141526", "", "1988", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "11.72", "11.72", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 277, "brand_name": "Caradon Ideal", "model_name": "Mexico Super", "model_qualifier": "cf40", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 11.72, "final_year_of_manufacture": 1988, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000277", "000008", "0", "2010/Sep/13 17:03", "Caradon Ideal", "Caradon Ideal", "Mexico Super", "cf40", "4141549", "", "1988", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "11.72", "11.72", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 278, "brand_name": "Caradon Ideal", "model_name": "Mexico Super", "model_qualifier": "cf40/60", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 17.6, "final_year_of_manufacture": 1988, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000278", "000008", "0", "2010/Sep/13 17:03", "Caradon Ideal", "Caradon Ideal", "Mexico Super", "cf40/60", "4141527", "", "1988", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "17.6", "17.6", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 280, "brand_name": "Caradon Ideal", "model_name": "Mexico Super", "model_qualifier": "cf55", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 16.12, "final_year_of_manufacture": 1988, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000280", "000008", "0", "2010/Sep/13 17:03", "Caradon Ideal", "Caradon Ideal", "Mexico Super", "cf55", "4140764", "", "1988", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "16.12", "16.12", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 281, "brand_name": "Caradon Ideal", "model_name": "Mexico Super", "model_qualifier": "cf65", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 19.05, "final_year_of_manufacture": 1988, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000281", "000008", "0", "2010/Sep/13 17:03", "Caradon Ideal", "Caradon Ideal", "Mexico Super", "cf65", "4140740", "", "1988", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "19.05", "19.05", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 282, "brand_name": "Caradon Ideal", "model_name": "Mexico Super", "model_qualifier": "cf75", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 22.0, "final_year_of_manufacture": 1988, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000282", "000008", "0", "2010/Sep/13 17:03", "Caradon Ideal", "Caradon Ideal", "Mexico Super", "cf75", "4140742", "", "1988", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "22", "22", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 283, "brand_name": "Caradon Ideal", "model_name": "Mexico Super", "model_qualifier": "cf80", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 23.45, "final_year_of_manufacture": 1988, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000283", "000008", "0", "2010/Sep/13 17:03", "Caradon Ideal", "Caradon Ideal", "Mexico Super", "cf80", "4140744", "", "1988", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "23.45", "23.45", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 284, "brand_name": "Caradon Ideal", "model_name": "Mexico Super", "model_qualifier": "rs100", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 29.3, "final_year_of_manufacture": 1988, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000284", "000008", "0", "2010/Sep/13 17:03", "Caradon Ideal", "Caradon Ideal", "Mexico Super", "rs100", "4140747", "", "1988", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "29.3", "29.3", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 285, "brand_name": "Caradon Ideal", "model_name": "Mexico Super", "model_qualifier": "rs125", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 36.64, "final_year_of_manufacture": 1988, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000285", "000008", "0", "2010/Sep/13 17:03", "Caradon Ideal", "Caradon Ideal", "Mexico Super", "rs125", "4140749", "", "1988", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "36.64", "36.64", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 286, "brand_name": "Caradon Ideal", "model_name": "Mexico Super", "model_qualifier": "rs30/40", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 11.72, "final_year_of_manufacture": 1988, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000286", "000008", "0", "2010/Sep/13 17:03", "Caradon Ideal", "Caradon Ideal", "Mexico Super", "rs30/40", "4141524", "", "1988", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "11.72", "11.72", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 287, "brand_name": "Caradon Ideal", "model_name": "Mexico Super", "model_qualifier": "rs40", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 11.72, "final_year_of_manufacture": 1988, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000287", "000008", "0", "2010/Sep/13 17:03", "Caradon Ideal", "Caradon Ideal", "Mexico Super", "rs40", "4141547", "", "1988", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "11.72", "11.72", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 289, "brand_name": "Caradon Ideal", "model_name": "Mexico Super", "model_qualifier": "rs40/60", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 17.58, "final_year_of_manufacture": 1988, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000289", "000008", "0", "2010/Sep/13 17:03", "Caradon Ideal", "Caradon Ideal", "Mexico Super", "rs40/60", "4141525", "", "1988", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "17.58", "17.58", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 290, "brand_name": "Caradon Ideal", "model_name": "Mexico Super", "model_qualifier": "rs55", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 16.12, "final_year_of_manufacture": 1988, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000290", "000008", "0", "2010/Sep/13 17:03", "Caradon Ideal", "Caradon Ideal", "Mexico Super", "rs55", "4140763", "", "1988", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "16.12", "16.12", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 292, "brand_name": "Caradon Ideal", "model_name": "Mexico Super", "model_qualifier": "rs65", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 19.05, "final_year_of_manufacture": 1988, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000292", "000008", "0", "2010/Sep/13 17:03", "Caradon Ideal", "Caradon Ideal", "Mexico Super", "rs65", "4140741", "", "1988", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "19.05", "19.05", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 293, "brand_name": "Caradon Ideal", "model_name": "Mexico Super", "model_qualifier": "rs75", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 22.0, "final_year_of_manufacture": 1988, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000293", "000008", "0", "2010/Sep/13 17:03", "Caradon Ideal", "Caradon Ideal", "Mexico Super", "rs75", "4140743", "", "1988", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "22", "22", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 294, "brand_name": "Caradon Ideal", "model_name": "Mexico Super", "model_qualifier": "rs80", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 23.45, "final_year_of_manufacture": 1988, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000294", "000008", "0", "2010/Sep/13 17:03", "Caradon Ideal", "Caradon Ideal", "Mexico Super", "rs80", "4140745", "", "1988", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "23.45", "23.45", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 413, "brand_name": "Chaffoteaux", "model_name": "Celtic", "model_qualifier": "ff", "winter_efficiency_pct": 71.0, "summer_efficiency_pct": 62.0, "comparative_hot_water_efficiency_pct": 43.2, "output_kw_max": 24.0, "final_year_of_manufacture": 1996, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000413", "000010", "0", "2010/Sep/13 17:03", "Chaffoteaux", "Chaffoteaux", "Celtic", "ff", "4798001", "", "1996", "1", "0", "0", "2", "0", "", "", "1", "2", "2", "24", "24", "", "", "71.0", "62.0", "", "43.2", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 414, "brand_name": "Chaffoteaux", "model_name": "Challenger", "model_qualifier": "30bf", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 8.7, "final_year_of_manufacture": 1990, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000414", "000010", "0", "2010/Sep/13 17:03", "Chaffoteaux", "Chaffoteaux", "Challenger", "30bf", "4198071", "", "1990", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "8.7", "8.7", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 415, "brand_name": "Chaffoteaux", "model_name": "Challenger", "model_qualifier": "30ff", "winter_efficiency_pct": 73.0, "summer_efficiency_pct": 63.0, "comparative_hot_water_efficiency_pct": 45.9, "output_kw_max": 8.79, "final_year_of_manufacture": 1990, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000415", "000010", "0", "2015/Jul/21 14:15", "Chaffoteaux", "Chaffoteaux", "Challenger", "30ff", "4198074", "", "1990", "1", "0", "0", "1", "0", "", "", "1", "2", "2", "8.79", "8.79", "", "", "73.0", "63.0", "", "45.9", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 416, "brand_name": "Chaffoteaux", "model_name": "Challenger", "model_qualifier": "30of", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 9.0, "final_year_of_manufacture": 1990, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000416", "000010", "0", "2010/Sep/13 17:03", "Chaffoteaux", "Chaffoteaux", "Challenger", "30of", "4198072", "", "1990", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "9", "9", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 417, "brand_name": "Chaffoteaux", "model_name": "Challenger", "model_qualifier": "40bf", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 11.6, "final_year_of_manufacture": 1990, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000417", "000010", "0", "2010/Sep/13 17:03", "Chaffoteaux", "Chaffoteaux", "Challenger", "40bf", "4198075", "", "1990", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "11.6", "11.6", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 418, "brand_name": "Chaffoteaux", "model_name": "Challenger", "model_qualifier": "50ff", "winter_efficiency_pct": 73.0, "summer_efficiency_pct": 63.0, "comparative_hot_water_efficiency_pct": 45.9, "output_kw_max": 14.65, "final_year_of_manufacture": 1990, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000418", "000010", "0", "2015/Jul/21 14:15", "Chaffoteaux", "Chaffoteaux", "Challenger", "50ff", "4198077", "", "1990", "1", "0", "0", "1", "0", "", "", "1", "2", "2", "14.65", "14.65", "", "", "73.0", "63.0", "", "45.9", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 419, "brand_name": "Chaffoteaux", "model_name": "Challenger", "model_qualifier": "50of", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 14.6, "final_year_of_manufacture": 1990, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000419", "000010", "0", "2010/Sep/13 17:03", "Chaffoteaux", "Chaffoteaux", "Challenger", "50of", "4198076", "", "1990", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "14.6", "14.6", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 420, "brand_name": "Chaffoteaux", "model_name": "Corvec", "model_qualifier": "28bf", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 8.2, "final_year_of_manufacture": 1984, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000420", "000010", "0", "2010/Sep/13 17:03", "Chaffoteaux", "Chaffoteaux", "Corvec", "28bf", "4198027", "", "1984", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "8.2", "8.2", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 421, "brand_name": "Chaffoteaux", "model_name": "Corvec", "model_qualifier": "28of", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 8.2, "final_year_of_manufacture": 1984, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000421", "000010", "0", "2010/Sep/13 17:03", "Chaffoteaux", "Chaffoteaux", "Corvec", "28of", "4198028", "", "1984", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "8.2", "8.2", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 422, "brand_name": "Chaffoteaux", "model_name": "Corvec", "model_qualifier": "28s", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 8.2, "final_year_of_manufacture": 1984, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000422", "000010", "0", "2010/Sep/13 17:03", "Chaffoteaux", "Chaffoteaux", "Corvec", "28s", "4198044", "", "1984", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "8.2", "8.2", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 423, "brand_name": "Chaffoteaux", "model_name": "Corvec", "model_qualifier": "45bf", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 13.2, "final_year_of_manufacture": 1984, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000423", "000010", "0", "2010/Sep/13 17:03", "Chaffoteaux", "Chaffoteaux", "Corvec", "45bf", "4198029", "", "1984", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "13.2", "13.2", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 424, "brand_name": "Chaffoteaux", "model_name": "Corvec", "model_qualifier": "45of", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 13.2, "final_year_of_manufacture": 1984, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000424", "000010", "0", "2010/Sep/13 17:03", "Chaffoteaux", "Chaffoteaux", "Corvec", "45of", "4198030", "", "1984", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "13.2", "13.2", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 425, "brand_name": "Chaffoteaux", "model_name": "Corvec", "model_qualifier": "45s", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 13.2, "final_year_of_manufacture": 1984, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000425", "000010", "0", "2010/Sep/13 17:03", "Chaffoteaux", "Chaffoteaux", "Corvec", "45s", "4198045", "", "1984", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "13.2", "13.2", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 426, "brand_name": "Chaffoteaux", "model_name": "Corvec", "model_qualifier": "48cf", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": null, "final_year_of_manufacture": 1978, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000426", "000010", "0", "2010/Sep/13 17:03", "Chaffoteaux", "Chaffoteaux", "Corvec", "48cf", "4198001", "", "1978", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "", "", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 427, "brand_name": "Chaffoteaux", "model_name": "Corvec", "model_qualifier": "64cf", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": null, "final_year_of_manufacture": 1978, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000427", "000010", "0", "2010/Sep/13 17:03", "Chaffoteaux", "Chaffoteaux", "Corvec", "64cf", "4198003", "", "1978", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "", "", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 428, "brand_name": "Chaffoteaux", "model_name": "Corvec", "model_qualifier": "80cf", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": null, "final_year_of_manufacture": 1978, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000428", "000010", "0", "2010/Sep/13 17:03", "Chaffoteaux", "Chaffoteaux", "Corvec", "80cf", "4198005", "", "1978", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "", "", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 429, "brand_name": "Chaffoteaux", "model_name": "Corvec Maxiflame", "model_qualifier": "2bf", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 17.58, "final_year_of_manufacture": 1979, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000429", "000010", "0", "2010/Sep/13 17:03", "Chaffoteaux", "Chaffoteaux", "Corvec Maxiflame", "2bf", "4198046", "", "1979", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "17.58", "17.58", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 433, "brand_name": "Chaffoteaux", "model_name": "Corvec Miniflame", "model_qualifier": "cf", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 8.2, "final_year_of_manufacture": 1977, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000433", "000010", "0", "2010/Sep/13 17:03", "Chaffoteaux", "Chaffoteaux", "Corvec Miniflame", "cf", "4198020", "", "1977", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "8.2", "8.2", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 456, "brand_name": "Claudio GR (Vokera)", "model_name": "Excell", "model_qualifier": "80SP", "winter_efficiency_pct": 74.0, "summer_efficiency_pct": 64.0, "comparative_hot_water_efficiency_pct": 44.9, "output_kw_max": 23.7, "final_year_of_manufacture": 1999, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000456", "000011", "0", "2010/Sep/13 17:03", "Claudio GR (Vokera)", "Claudio GR (Vokera)", "Excell", "80SP", "4709417", "", "1999", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "23.7", "23.7", "", "", "74.0", "64.0", "", "44.9", "", "3", "", "", "0", "2", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 457, "brand_name": "Vokera", "model_name": "Excell", "model_qualifier": "80E", "winter_efficiency_pct": 73.0, "summer_efficiency_pct": 64.0, "comparative_hot_water_efficiency_pct": 45.0, "output_kw_max": 23.7, "final_year_of_manufacture": 1999, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000457", "000011", "0", "2010/Sep/13 17:03", "Vokera", "Vokera", "Excell", "80E", "4709418", "", "1999", "1", "0", "0", "2", "0", "", "", "1", "2", "2", "23.7", "23.7", "", "", "73.0", "64.0", "", "45.0", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 458, "brand_name": "Vokera", "model_name": "Excell", "model_qualifier": "96E", "winter_efficiency_pct": 73.0, "summer_efficiency_pct": 64.0, "comparative_hot_water_efficiency_pct": 45.0, "output_kw_max": 28.0, "final_year_of_manufacture": 1999, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000458", "000011", "0", "2010/Sep/13 17:03", "Vokera", "Vokera", "Excell", "96E", "4709414", "", "1999", "1", "0", "0", "2", "0", "", "", "1", "2", "2", "28", "28", "", "", "73.0", "64.0", "", "45.0", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 467, "brand_name": "Vokera", "model_name": "Meteor", "model_qualifier": "V90", "winter_efficiency_pct": 69.0, "summer_efficiency_pct": 59.0, "comparative_hot_water_efficiency_pct": 43.0, "output_kw_max": 26.1, "final_year_of_manufacture": 1999, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000467", "000011", "0", "2010/Sep/13 17:03", "Vokera", "Vokera", "Meteor", "V90", "4709420", "", "1999", "1", "0", "0", "1", "0", "", "", "1", "2", "2", "26.1", "26.1", "", "", "69.0", "59.0", "", "43.0", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 468, "brand_name": "Vokera", "model_name": "Meteor", "model_qualifier": "S90", "winter_efficiency_pct": 69.0, "summer_efficiency_pct": 59.0, "comparative_hot_water_efficiency_pct": 43.0, "output_kw_max": 26.1, "final_year_of_manufacture": 1999, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000468", "000011", "0", "2010/Sep/13 17:03", "Vokera", "Vokera", "Meteor", "S90", "4709421", "", "1999", "1", "0", "0", "1", "0", "", "", "1", "2", "2", "26.1", "26.1", "", "", "69.0", "59.0", "", "43.0", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 474, "brand_name": "Ferroli", "model_name": "Combi", "model_qualifier": "76ff", "winter_efficiency_pct": 71.0, "summer_efficiency_pct": 62.0, "comparative_hot_water_efficiency_pct": 43.2, "output_kw_max": 22.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000474", "000097", "0", "2010/Sep/13 17:03", "Ferroli", "Ferroli", "Combi", "76ff", "4726703", "", "obsolete", "1", "0", "0", "2", "0", "", "", "1", "2", "2", "22.3", "22.3", "", "", "71.0", "62.0", "", "43.2", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 478, "brand_name": "Ferroli", "model_name": "Roma", "model_qualifier": "55ff", "winter_efficiency_pct": 73.0, "summer_efficiency_pct": 63.0, "comparative_hot_water_efficiency_pct": 45.9, "output_kw_max": 16.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000478", "000097", "0", "2015/Jul/21 14:15", "Ferroli", "Ferroli", "Roma", "55ff", "4126705", "", "obsolete", "1", "0", "0", "1", "0", "", "", "1", "2", "2", "16", "16", "", "", "73.0", "63.0", "", "45.9", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 488, "brand_name": "Ferroli", "model_name": "Xignal", "model_qualifier": "Xignal", "winter_efficiency_pct": 69.0, "summer_efficiency_pct": 59.0, "comparative_hot_water_efficiency_pct": 43.0, "output_kw_max": 27.9, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000488", "000097", "0", "2010/Sep/13 17:03", "Ferroli", "Ferroli", "Xignal", "Xignal", "", "", "obsolete", "1", "0", "0", "1", "0", "", "", "1", "2", "2", "27.9", "27.9", "", "", "69.0", "59.0", "", "43.0", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 489, "brand_name": "Ferroli", "model_name": "Hawk II", "model_qualifier": "Hawk II", "winter_efficiency_pct": 69.0, "summer_efficiency_pct": 59.0, "comparative_hot_water_efficiency_pct": 43.0, "output_kw_max": 23.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000489", "000097", "0", "2010/Sep/13 17:03", "Ferroli", "Ferroli", "Hawk II", "Hawk II", "", "", "obsolete", "1", "0", "0", "1", "0", "", "", "1", "2", "2", "23.3", "23.3", "", "", "69.0", "59.0", "", "43.0", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 490, "brand_name": "Halstead", "model_name": "30/90Combi", "model_qualifier": "30/90combi", "winter_efficiency_pct": 71.0, "summer_efficiency_pct": 62.0, "comparative_hot_water_efficiency_pct": 43.2, "output_kw_max": 23.4, "final_year_of_manufacture": 1994, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000490", "000019", "0", "2010/Sep/13 17:03", "Halstead Boilers", "Halstead", "30/90Combi", "30/90combi", "4728301", "", "1994", "1", "0", "0", "2", "0", "", "", "1", "2", "2", "23.4", "23.4", "", "", "71.0", "62.0", "", "43.2", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 491, "brand_name": "Halstead", "model_name": "Blenheim", "model_qualifier": "15/30", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 8.79, "final_year_of_manufacture": 1995, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000491", "000019", "0", "2010/Sep/13 17:03", "Halstead Boilers", "Halstead", "Blenheim", "15/30", "4133320", "", "1995", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "8.79", "8.79", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 492, "brand_name": "Halstead", "model_name": "Blenheim", "model_qualifier": "30/40", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 11.72, "final_year_of_manufacture": 1995, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000492", "000019", "0", "2010/Sep/13 17:03", "Halstead Boilers", "Halstead", "Blenheim", "30/40", "4133316", "", "1995", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "11.72", "11.72", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 493, "brand_name": "Halstead", "model_name": "Blenheim", "model_qualifier": "40", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 12.46, "final_year_of_manufacture": 1995, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000493", "000019", "0", "2010/Sep/13 17:03", "Halstead Boilers", "Halstead", "Blenheim", "40", "4133305", "", "1995", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "12.46", "12.46", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 494, "brand_name": "Halstead", "model_name": "Blenheim", "model_qualifier": "40/50", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 14.65, "final_year_of_manufacture": 1995, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000494", "000019", "0", "2010/Sep/13 17:03", "Halstead Boilers", "Halstead", "Blenheim", "40/50", "4133317", "", "1995", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "14.65", "14.65", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 495, "brand_name": "Halstead", "model_name": "Blenheim", "model_qualifier": "50", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 15.53, "final_year_of_manufacture": 1995, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000495", "000019", "0", "2010/Sep/13 17:03", "Halstead Boilers", "Halstead", "Blenheim", "50", "4133306", "", "1995", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "15.53", "15.53", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 496, "brand_name": "Halstead", "model_name": "Blenheim", "model_qualifier": "50/60", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 17.58, "final_year_of_manufacture": 1995, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000496", "000019", "0", "2010/Sep/13 17:03", "Halstead Boilers", "Halstead", "Blenheim", "50/60", "4133318", "", "1995", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "17.58", "17.58", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 497, "brand_name": "Halstead", "model_name": "Blenheim", "model_qualifier": "60/75", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 21.98, "final_year_of_manufacture": 1995, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000497", "000019", "0", "2010/Sep/13 17:03", "Halstead Boilers", "Halstead", "Blenheim", "60/75", "4133319", "", "1995", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "21.98", "21.98", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 508, "brand_name": "Halstead", "model_name": "40h", "model_qualifier": "", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 12.46, "final_year_of_manufacture": 1986, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000508", "000019", "0", "2010/Sep/13 17:03", "Halstead Boilers", "Halstead", "40h", "", "4133301", "", "1986", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "12.46", "12.46", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 509, "brand_name": "Halstead", "model_name": "Balmoral", "model_qualifier": "45f", "winter_efficiency_pct": 73.0, "summer_efficiency_pct": 63.0, "comparative_hot_water_efficiency_pct": 45.9, "output_kw_max": 13.19, "final_year_of_manufacture": 1996, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000509", "000019", "0", "2015/Jul/21 14:15", "Halstead Boilers", "Halstead", "Balmoral", "45f", "4133311", "", "1996", "1", "0", "0", "1", "0", "", "", "1", "2", "2", "13.19", "13.19", "", "", "73.0", "63.0", "", "45.9", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 510, "brand_name": "Halstead", "model_name": "50h", "model_qualifier": "", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 15.53, "final_year_of_manufacture": 1986, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000510", "000019", "0", "2010/Sep/13 17:03", "Halstead Boilers", "Halstead", "50h", "", "4133302", "", "1986", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "15.53", "15.53", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 511, "brand_name": "Halstead", "model_name": "Balmoral", "model_qualifier": "65f", "winter_efficiency_pct": 73.0, "summer_efficiency_pct": 63.0, "comparative_hot_water_efficiency_pct": 45.9, "output_kw_max": 19.05, "final_year_of_manufacture": 1996, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000511", "000019", "0", "2015/Jul/21 14:15", "Halstead Boilers", "Halstead", "Balmoral", "65f", "4133312", "", "1996", "1", "0", "0", "1", "0", "", "", "1", "2", "2", "19.05", "19.05", "", "", "73.0", "63.0", "", "45.9", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 512, "brand_name": "Halstead", "model_name": "Triocombi", "model_qualifier": "triocombi", "winter_efficiency_pct": 71.0, "summer_efficiency_pct": 62.0, "comparative_hot_water_efficiency_pct": 43.2, "output_kw_max": 23.4, "final_year_of_manufacture": 1994, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000512", "000019", "0", "2010/Sep/13 17:03", "Halstead Boilers", "Halstead", "Triocombi", "triocombi", "4728301", "", "1994", "1", "0", "0", "2", "0", "", "", "1", "2", "2", "23.4", "23.4", "", "", "71.0", "62.0", "", "43.2", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 513, "brand_name": "Halstead", "model_name": "Quattro", "model_qualifier": "Quattro", "winter_efficiency_pct": 71.0, "summer_efficiency_pct": 62.0, "comparative_hot_water_efficiency_pct": 43.2, "output_kw_max": 23.4, "final_year_of_manufacture": 1997, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000513", "000019", "0", "2010/Sep/13 17:03", "Halstead Boilers", "Halstead", "Quattro", "Quattro", "", "", "1997", "1", "0", "0", "2", "0", "", "", "1", "2", "2", "23.4", "23.4", "", "", "71.0", "62.0", "", "43.2", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 520, "brand_name": "Halstead", "model_name": "Buckingham II", "model_qualifier": "BF40", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 11.7, "final_year_of_manufacture": 1996, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000520", "000019", "0", "2010/Sep/13 17:03", "Halstead Boilers", "Halstead", "Buckingham II", "BF40", "", "", "1996", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "11.7", "11.7", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 521, "brand_name": "Halstead", "model_name": "Buckingham II", "model_qualifier": "BF50", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 14.7, "final_year_of_manufacture": 1996, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000521", "000019", "0", "2010/Sep/13 17:03", "Halstead Boilers", "Halstead", "Buckingham II", "BF50", "", "", "1996", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "14.7", "14.7", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 522, "brand_name": "Halstead", "model_name": "Buckingham II", "model_qualifier": "BF60", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 17.6, "final_year_of_manufacture": 1996, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000522", "000019", "0", "2010/Sep/13 17:03", "Halstead Boilers", "Halstead", "Buckingham II", "BF60", "", "", "1996", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "17.6", "17.6", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 523, "brand_name": "Halstead", "model_name": "Buckingham II", "model_qualifier": "BF70", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 20.5, "final_year_of_manufacture": 1996, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000523", "000019", "0", "2010/Sep/13 17:03", "Halstead Boilers", "Halstead", "Buckingham II", "BF70", "", "", "1996", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "20.5", "20.5", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 524, "brand_name": "Halstead", "model_name": "Buckingham II", "model_qualifier": "BF80", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 23.4, "final_year_of_manufacture": 1996, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000524", "000019", "0", "2010/Sep/13 17:03", "Halstead Boilers", "Halstead", "Buckingham II", "BF80", "", "", "1996", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "23.4", "23.4", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 525, "brand_name": "Halstead", "model_name": "Buckingham II", "model_qualifier": "BF100", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 27.8, "final_year_of_manufacture": 1996, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000525", "000019", "0", "2010/Sep/13 17:03", "Halstead Boilers", "Halstead", "Buckingham II", "BF100", "", "", "1996", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "27.8", "27.8", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 526, "brand_name": "Halstead", "model_name": "Buckingham II", "model_qualifier": "CF40", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 11.7, "final_year_of_manufacture": 1996, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000526", "000019", "0", "2010/Sep/13 17:03", "Halstead Boilers", "Halstead", "Buckingham II", "CF40", "", "", "1996", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "11.7", "11.7", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 527, "brand_name": "Halstead", "model_name": "Buckingham II", "model_qualifier": "CF50", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 14.7, "final_year_of_manufacture": 1996, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000527", "000019", "0", "2010/Sep/13 17:03", "Halstead Boilers", "Halstead", "Buckingham II", "CF50", "", "", "1996", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "14.7", "14.7", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 528, "brand_name": "Halstead", "model_name": "Buckingham II", "model_qualifier": "CF60", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 17.6, "final_year_of_manufacture": 1996, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000528", "000019", "0", "2010/Sep/13 17:03", "Halstead Boilers", "Halstead", "Buckingham II", "CF60", "", "", "1996", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "17.6", "17.6", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 529, "brand_name": "Halstead", "model_name": "Buckingham II", "model_qualifier": "CF70", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 20.5, "final_year_of_manufacture": 1996, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000529", "000019", "0", "2010/Sep/13 17:03", "Halstead Boilers", "Halstead", "Buckingham II", "CF70", "", "", "1996", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "20.5", "20.5", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 530, "brand_name": "Halstead", "model_name": "Buckingham II", "model_qualifier": "CF80", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 23.4, "final_year_of_manufacture": 1996, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000530", "000019", "0", "2010/Sep/13 17:03", "Halstead Boilers", "Halstead", "Buckingham II", "CF80", "", "", "1996", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "23.4", "23.4", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 531, "brand_name": "Halstead", "model_name": "Buckingham II", "model_qualifier": "CF100", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 27.8, "final_year_of_manufacture": 1996, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000531", "000019", "0", "2010/Sep/13 17:03", "Halstead Boilers", "Halstead", "Buckingham II", "CF100", "", "", "1996", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "27.8", "27.8", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 533, "brand_name": "Hepworth Heating", "model_name": "Economy", "model_qualifier": "30F", "winter_efficiency_pct": 73.0, "summer_efficiency_pct": 63.0, "comparative_hot_water_efficiency_pct": 45.9, "output_kw_max": 8.79, "final_year_of_manufacture": 1992, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000533", "000020", "0", "2015/Jul/21 14:15", "Hepworth Heating", "Hepworth Heating", "Economy", "30F", "4131905", "", "1992", "1", "0", "0", "1", "0", "", "", "1", "2", "2", "8.79", "8.79", "", "", "73.0", "63.0", "", "45.9", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 535, "brand_name": "Hepworth Heating", "model_name": "Economy", "model_qualifier": "40F", "winter_efficiency_pct": 73.0, "summer_efficiency_pct": 63.0, "comparative_hot_water_efficiency_pct": 45.9, "output_kw_max": 11.72, "final_year_of_manufacture": 1992, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000535", "000020", "0", "2015/Jul/21 14:15", "Hepworth Heating", "Hepworth Heating", "Economy", "40F", "4131906", "", "1992", "1", "0", "0", "1", "0", "", "", "1", "2", "2", "11.72", "11.72", "", "", "73.0", "63.0", "", "45.9", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 537, "brand_name": "Hepworth Heating", "model_name": "Economy", "model_qualifier": "50F", "winter_efficiency_pct": 73.0, "summer_efficiency_pct": 63.0, "comparative_hot_water_efficiency_pct": 45.9, "output_kw_max": 14.65, "final_year_of_manufacture": 1992, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000537", "000020", "0", "2015/Jul/21 14:15", "Hepworth Heating", "Hepworth Heating", "Economy", "50F", "4131907", "", "1992", "1", "0", "0", "1", "0", "", "", "1", "2", "2", "14.65", "14.65", "", "", "73.0", "63.0", "", "45.9", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 549, "brand_name": "Glow-worm", "model_name": "Spacesaver Complheat", "model_qualifier": "60", "winter_efficiency_pct": 73.0, "summer_efficiency_pct": 63.0, "comparative_hot_water_efficiency_pct": 45.9, "output_kw_max": 17.59, "final_year_of_manufacture": 1997, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000549", "000207", "0", "2015/Jul/21 14:15", "Hepworth Heating", "Glow-worm", "Spacesaver Complheat", "60", "4131945", "", "1997", "1", "0", "0", "1", "0", "", "", "1", "2", "2", "17.59", "17.59", "", "", "73.0", "63.0", "", "45.9", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 550, "brand_name": "Glow-worm", "model_name": "Spacesaver Complheat", "model_qualifier": "70", "winter_efficiency_pct": 73.0, "summer_efficiency_pct": 63.0, "comparative_hot_water_efficiency_pct": 45.9, "output_kw_max": 20.52, "final_year_of_manufacture": 1997, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000550", "000207", "0", "2015/Jul/21 14:15", "Hepworth Heating", "Glow-worm", "Spacesaver Complheat", "70", "4131946", "", "1997", "1", "0", "0", "1", "0", "", "", "1", "2", "2", "20.52", "20.52", "", "", "73.0", "63.0", "", "45.9", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 551, "brand_name": "Glow-worm", "model_name": "Spacesaver Kfb", "model_qualifier": "20", "winter_efficiency_pct": 69.0, "summer_efficiency_pct": 59.0, "comparative_hot_water_efficiency_pct": 43.0, "output_kw_max": 5.86, "final_year_of_manufacture": 1998, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000551", "000207", "0", "2010/Sep/13 17:03", "Hepworth Heating", "Glow-worm", "Spacesaver Kfb", "20", "4131922", "", "1998", "1", "0", "0", "1", "0", "", "", "1", "2", "2", "5.86", "5.86", "", "", "69.0", "59.0", "", "43.0", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 552, "brand_name": "Glow-worm", "model_name": "Spacesaver Kfb", "model_qualifier": "60", "winter_efficiency_pct": 69.0, "summer_efficiency_pct": 59.0, "comparative_hot_water_efficiency_pct": 43.0, "output_kw_max": 17.59, "final_year_of_manufacture": 1997, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000552", "000207", "0", "2010/Sep/13 17:03", "Hepworth Heating", "Glow-worm", "Spacesaver Kfb", "60", "4131911", "", "1997", "1", "0", "0", "1", "0", "", "", "1", "2", "2", "17.59", "17.59", "", "", "69.0", "59.0", "", "43.0", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 553, "brand_name": "Glow-worm", "model_name": "Spacesaver Kfb", "model_qualifier": "70", "winter_efficiency_pct": 69.0, "summer_efficiency_pct": 59.0, "comparative_hot_water_efficiency_pct": 43.0, "output_kw_max": 20.52, "final_year_of_manufacture": 1997, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000553", "000207", "0", "2010/Sep/13 17:03", "Hepworth Heating", "Glow-worm", "Spacesaver Kfb", "70", "4131912", "", "1997", "1", "0", "0", "1", "0", "", "", "1", "2", "2", "20.52", "20.52", "", "", "69.0", "59.0", "", "43.0", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 571, "brand_name": "Glow-worm", "model_name": "Economy Plus", "model_qualifier": "75B", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": null, "final_year_of_manufacture": 1997, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000571", "000207", "0", "2010/Sep/13 17:03", "Hepworth Heating", "Glow-worm", "Economy Plus", "75B", "4131962", "", "1997", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "", "", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 574, "brand_name": "Malvern", "model_name": "70", "model_qualifier": "NG", "winter_efficiency_pct": 91.0, "summer_efficiency_pct": 74.0, "comparative_hot_water_efficiency_pct": 53.7, "output_kw_max": null, "final_year_of_manufacture": 1995, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000574", "000023", "0", "2010/Sep/13 17:03", "Malvern Boilers", "Malvern", "70", "NG", "", "", "1995", "1", "0", "0", "1", "0", "", "", "2", "2", "2", "", "", "", "", "91.0", "74.0", "", "53.7", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0001", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 579, "brand_name": "Potterton Myson", "model_name": "FRS 52", "model_qualifier": "", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": null, "final_year_of_manufacture": 1974, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000579", "000005", "0", "2010/Sep/13 17:03", "Potterton Myson", "Potterton Myson", "FRS 52", "", "41 595 96", "", "1974", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "", "", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 581, "brand_name": "Potterton International Heating", "model_name": "C40", "model_qualifier": "c40/12", "winter_efficiency_pct": 56.0, "summer_efficiency_pct": 46.0, "comparative_hot_water_efficiency_pct": 33.5, "output_kw_max": 11.1, "final_year_of_manufacture": 1972, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000581", "000005", "0", "2010/Sep/13 17:03", "Potterton International Heating", "Potterton International Heating", "C40", "c40/12", "4159502", "", "1972", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "11.1", "11.1", "", "", "56.0", "46.0", "", "33.5", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 582, "brand_name": "Potterton Myson", "model_name": "C40", "model_qualifier": "c40/12", "winter_efficiency_pct": 56.0, "summer_efficiency_pct": 46.0, "comparative_hot_water_efficiency_pct": 33.5, "output_kw_max": 11.1, "final_year_of_manufacture": 1976, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000582", "000005", "0", "2010/Sep/13 17:03", "Potterton Myson", "Potterton Myson", "C40", "c40/12", "4159586", "", "1976", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "11.1", "11.1", "", "", "56.0", "46.0", "", "33.5", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 589, "brand_name": "Potterton International Heating", "model_name": "C50", "model_qualifier": "c50/15", "winter_efficiency_pct": 56.0, "summer_efficiency_pct": 46.0, "comparative_hot_water_efficiency_pct": 33.5, "output_kw_max": 13.8, "final_year_of_manufacture": 1976, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000589", "000005", "0", "2010/Sep/13 17:03", "Potterton International Heating", "Potterton International Heating", "C50", "c50/15", "4159564", "", "1976", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "13.8", "13.8", "", "", "56.0", "46.0", "", "33.5", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 590, "brand_name": "Potterton Myson", "model_name": "C55", "model_qualifier": "c55/16", "winter_efficiency_pct": 56.0, "summer_efficiency_pct": 46.0, "comparative_hot_water_efficiency_pct": 33.5, "output_kw_max": 16.1, "final_year_of_manufacture": 1976, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000590", "000005", "0", "2010/Sep/13 17:03", "Potterton Myson", "Potterton Myson", "C55", "c55/16", "4160105", "", "1976", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "16.1", "16.1", "", "", "56.0", "46.0", "", "33.5", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 593, "brand_name": "Potterton International Heating", "model_name": "C70", "model_qualifier": "c70/21", "winter_efficiency_pct": 56.0, "summer_efficiency_pct": 46.0, "comparative_hot_water_efficiency_pct": 33.5, "output_kw_max": 19.6, "final_year_of_manufacture": 1976, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000593", "000005", "0", "2010/Sep/13 17:03", "Potterton International Heating", "Potterton International Heating", "C70", "c70/21", "4159565", "", "1976", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "19.6", "19.6", "", "", "56.0", "46.0", "", "33.5", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 595, "brand_name": "Potterton Myson", "model_name": "C80", "model_qualifier": "c80/23", "winter_efficiency_pct": 56.0, "summer_efficiency_pct": 46.0, "comparative_hot_water_efficiency_pct": 33.5, "output_kw_max": 22.6, "final_year_of_manufacture": 1976, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000595", "000005", "0", "2010/Sep/13 17:03", "Potterton Myson", "Potterton Myson", "C80", "c80/23", "4159505", "", "1976", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "22.6", "22.6", "", "", "56.0", "46.0", "", "33.5", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 596, "brand_name": "Potterton International Heating", "model_name": "C80", "model_qualifier": "c80/23", "winter_efficiency_pct": 56.0, "summer_efficiency_pct": 46.0, "comparative_hot_water_efficiency_pct": 33.5, "output_kw_max": 22.6, "final_year_of_manufacture": 1976, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000596", "000005", "0", "2010/Sep/13 17:03", "Potterton International Heating", "Potterton International Heating", "C80", "c80/23", "4159566", "", "1976", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "22.6", "22.6", "", "", "56.0", "46.0", "", "33.5", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 598, "brand_name": "Potterton Myson", "model_name": "C95", "model_qualifier": "c95/28", "winter_efficiency_pct": 56.0, "summer_efficiency_pct": 46.0, "comparative_hot_water_efficiency_pct": 33.5, "output_kw_max": 26.7, "final_year_of_manufacture": 1972, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000598", "000005", "0", "2010/Sep/13 17:03", "Potterton Myson", "Potterton Myson", "C95", "c95/28", "4159567", "", "1972", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "26.7", "26.7", "", "", "56.0", "46.0", "", "33.5", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 599, "brand_name": "Potterton International Heating", "model_name": "C95", "model_qualifier": "c95/28", "winter_efficiency_pct": 56.0, "summer_efficiency_pct": 46.0, "comparative_hot_water_efficiency_pct": 33.5, "output_kw_max": 26.7, "final_year_of_manufacture": 1972, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000599", "000005", "0", "2010/Sep/13 17:03", "Potterton International Heating", "Potterton International Heating", "C95", "c95/28", "4159506", "", "1972", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "26.7", "26.7", "", "", "56.0", "46.0", "", "33.5", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 600, "brand_name": "Potterton International Heating", "model_name": "Fireside", "model_qualifier": "35/51", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": null, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000600", "000005", "0", "2010/Sep/13 17:03", "Potterton International Heating", "Potterton International Heating", "Fireside", "35/51", "4459015", "", "obsolete", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "", "", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 601, "brand_name": "Potterton International Heating", "model_name": "Fireside", "model_qualifier": "50", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": null, "final_year_of_manufacture": 1972, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000601", "000005", "0", "2010/Sep/13 17:03", "Potterton International Heating", "Potterton International Heating", "Fireside", "50", "4459002", "", "1972", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "", "", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 602, "brand_name": "Potterton International Heating", "model_name": "Fireside", "model_qualifier": "50tg", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": null, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000602", "000005", "0", "2010/Sep/13 17:03", "Potterton International Heating", "Potterton International Heating", "Fireside", "50tg", "4459001", "", "obsolete", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "", "", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 604, "brand_name": "Potterton International Heating", "model_name": "Fireside", "model_qualifier": "51", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": null, "final_year_of_manufacture": 1976, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000604", "000005", "0", "2010/Sep/13 17:03", "Potterton International Heating", "Potterton International Heating", "Fireside", "51", "4459004", "", "1976", "1", "4", "1", "1", "0", "", "", "1", "1", "1", "", "", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "0", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 605, "brand_name": "Potterton Myson", "model_name": "Fireside", "model_qualifier": "52", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": null, "final_year_of_manufacture": 1976, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000605", "000005", "0", "2010/Sep/13 17:03", "Potterton Myson", "Potterton Myson", "Fireside", "52", "4459006", "", "1976", "1", "4", "0", "1", "0", "", "", "1", "1", "1", "", "", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 606, "brand_name": "Potterton International Heating", "model_name": "Fireside", "model_qualifier": "52", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": null, "final_year_of_manufacture": 1976, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000606", "000005", "0", "2010/Sep/13 17:03", "Potterton International Heating", "Potterton International Heating", "Fireside", "52", "4459005", "", "1976", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "", "", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 607, "brand_name": "Potterton International Heating", "model_name": "Fireside", "model_qualifier": "fs44lbe", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": null, "final_year_of_manufacture": 1972, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000607", "000005", "0", "2010/Sep/13 17:03", "Potterton International Heating", "Potterton International Heating", "Fireside", "fs44lbe", "4159507", "", "1972", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "", "", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 608, "brand_name": "Potterton International Heating", "model_name": "Fireside", "model_qualifier": "super", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": null, "final_year_of_manufacture": 1986, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000608", "000005", "0", "2010/Sep/13 17:03", "Potterton International Heating", "Potterton International Heating", "Fireside", "super", "4459013", "", "1986", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "", "", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 609, "brand_name": "Potterton International Heating", "model_name": "Flamingo", "model_qualifier": "50of", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 14.65, "final_year_of_manufacture": 1986, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000609", "000005", "0", "2010/Sep/13 17:03", "Potterton International Heating", "Potterton International Heating", "Flamingo", "50of", "4160118", "", "1986", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "14.65", "14.65", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 610, "brand_name": "Potterton Myson", "model_name": "Flamingo", "model_qualifier": "cf20-30", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 8.8, "final_year_of_manufacture": 1986, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000610", "000005", "0", "2010/Sep/13 17:03", "Potterton Myson", "Potterton Myson", "Flamingo", "cf20-30", "4160133", "", "1986", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "8.8", "8.8", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 611, "brand_name": "Potterton International Heating", "model_name": "Flamingo", "model_qualifier": "cf20/35", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 10.26, "final_year_of_manufacture": 1995, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000611", "000005", "0", "2010/Sep/13 17:03", "Potterton International Heating", "Potterton International Heating", "Flamingo", "cf20/35", "4160559", "", "1995", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "10.26", "10.26", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 612, "brand_name": "Potterton International Heating", "model_name": "Flamingo", "model_qualifier": "cf35/50", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 14.65, "final_year_of_manufacture": 1995, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000612", "000005", "0", "2010/Sep/13 17:03", "Potterton International Heating", "Potterton International Heating", "Flamingo", "cf35/50", "4160560", "", "1995", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "14.65", "14.65", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 613, "brand_name": "Potterton Myson", "model_name": "Flamingo", "model_qualifier": "rs20-30", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 8.8, "final_year_of_manufacture": 1986, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000613", "000005", "0", "2010/Sep/13 17:03", "Potterton Myson", "Potterton Myson", "Flamingo", "rs20-30", "4160123", "", "1986", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "8.8", "8.8", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 614, "brand_name": "Potterton International Heating", "model_name": "Flamingo", "model_qualifier": "rs20/35", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 10.26, "final_year_of_manufacture": 1995, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000614", "000005", "0", "2010/Sep/13 17:03", "Potterton International Heating", "Potterton International Heating", "Flamingo", "rs20/35", "4160557", "", "1995", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "10.26", "10.26", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 615, "brand_name": "Potterton Myson", "model_name": "Flamingo", "model_qualifier": "rs35/50", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 14.65, "final_year_of_manufacture": 1995, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000615", "000005", "0", "2010/Sep/13 17:03", "Potterton Myson", "Potterton Myson", "Flamingo", "rs35/50", "4160558", "", "1995", "1", "2", "1", "1", "0", "", "", "1", "2", "1", "14.65", "14.65", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 616, "brand_name": "Potterton Myson", "model_name": "Flamingo", "model_qualifier": "rs40", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 11.7, "final_year_of_manufacture": 1986, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000616", "000005", "0", "2010/Sep/13 17:03", "Potterton Myson", "Potterton Myson", "Flamingo", "rs40", "4160125", "", "1986", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "11.7", "11.7", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 617, "brand_name": "Potterton International Heating", "model_name": "Flamingo", "model_qualifier": "rs50", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 13.5, "final_year_of_manufacture": 1981, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000617", "000005", "0", "2010/Sep/13 17:03", "Potterton International Heating", "Potterton International Heating", "Flamingo", "rs50", "4160114", "", "1981", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "13.5", "13.5", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 618, "brand_name": "Potterton Myson", "model_name": "Flamingo", "model_qualifier": "rs50s", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 14.7, "final_year_of_manufacture": 1986, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000618", "000005", "0", "2010/Sep/13 17:03", "Potterton Myson", "Potterton Myson", "Flamingo", "rs50s", "4160143", "", "1986", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "14.7", "14.7", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 619, "brand_name": "Potterton Myson", "model_name": "Flamingo 2", "model_qualifier": "cf20/30", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 8.8, "final_year_of_manufacture": 1986, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000619", "000005", "0", "2010/Sep/13 17:03", "Potterton Myson", "Potterton Myson", "Flamingo 2", "cf20/30", "4160516", "", "1986", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "8.8", "8.8", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 620, "brand_name": "Potterton Myson", "model_name": "Flamingo 2", "model_qualifier": "cf50", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 14.65, "final_year_of_manufacture": 1986, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000620", "000005", "0", "2010/Sep/13 17:03", "Potterton Myson", "Potterton Myson", "Flamingo 2", "cf50", "4160514", "", "1986", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "14.65", "14.65", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 621, "brand_name": "Potterton Myson", "model_name": "Flamingo 2", "model_qualifier": "rs20/30", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 8.8, "final_year_of_manufacture": 1989, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000621", "000005", "0", "2010/Sep/13 17:03", "Potterton Myson", "Potterton Myson", "Flamingo 2", "rs20/30", "4160515", "", "1989", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "8.8", "8.8", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 622, "brand_name": "Potterton Myson", "model_name": "Flamingo 2", "model_qualifier": "rs40", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 11.7, "final_year_of_manufacture": 1986, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000622", "000005", "0", "2010/Sep/13 17:03", "Potterton Myson", "Potterton Myson", "Flamingo 2", "rs40", "4160512", "", "1986", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "11.7", "11.7", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 623, "brand_name": "Potterton Myson", "model_name": "Flamingo 2", "model_qualifier": "rs50", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 14.7, "final_year_of_manufacture": 1989, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000623", "000005", "0", "2010/Sep/13 17:03", "Potterton Myson", "Potterton Myson", "Flamingo 2", "rs50", "4160513", "", "1989", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "14.7", "14.7", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 624, "brand_name": "Potterton Myson", "model_name": "Kingfisher", "model_qualifier": "cf100", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 29.3, "final_year_of_manufacture": 1986, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000624", "000005", "0", "2010/Sep/13 17:03", "Potterton Myson", "Potterton Myson", "Kingfisher", "cf100", "4160142", "", "1986", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "29.3", "29.3", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 625, "brand_name": "Potterton International Heating", "model_name": "Kingfisher", "model_qualifier": "cf125", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 36.6, "final_year_of_manufacture": 1998, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000625", "000005", "0", "2010/Sep/13 17:03", "Potterton International Heating", "Potterton International Heating", "Kingfisher", "cf125", "4160115", "", "1998", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "36.6", "36.6", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 626, "brand_name": "Potterton International Heating", "model_name": "Kingfisher", "model_qualifier": "cf150", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 44.0, "final_year_of_manufacture": 1998, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000626", "000005", "0", "2010/Sep/13 17:03", "Potterton International Heating", "Potterton International Heating", "Kingfisher", "cf150", "4160116", "", "1998", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "44", "44", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 627, "brand_name": "Potterton Myson", "model_name": "Kingfisher", "model_qualifier": "cf40", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 11.7, "final_year_of_manufacture": 1983, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000627", "000005", "0", "2010/Sep/13 17:03", "Potterton Myson", "Potterton Myson", "Kingfisher", "cf40", "4160157", "", "1983", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "11.7", "11.7", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 628, "brand_name": "Potterton Myson", "model_name": "Kingfisher", "model_qualifier": "cf40a", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 11.7, "final_year_of_manufacture": 1986, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000628", "000005", "0", "2010/Sep/13 17:03", "Potterton Myson", "Potterton Myson", "Kingfisher", "cf40a", "4160160", "", "1986", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "11.7", "11.7", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 629, "brand_name": "Potterton International Heating", "model_name": "Kingfisher", "model_qualifier": "cf45", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 13.2, "final_year_of_manufacture": 1980, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000629", "000005", "0", "2010/Sep/13 17:03", "Potterton International Heating", "Potterton International Heating", "Kingfisher", "cf45", "4160107", "", "1980", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "13.2", "13.2", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 630, "brand_name": "Potterton Myson", "model_name": "Kingfisher", "model_qualifier": "cf50", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 14.6, "final_year_of_manufacture": 1985, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000630", "000005", "0", "2010/Sep/13 17:03", "Potterton Myson", "Potterton Myson", "Kingfisher", "cf50", "4160158", "", "1985", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "14.6", "14.6", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 631, "brand_name": "Potterton Myson", "model_name": "Kingfisher", "model_qualifier": "cf50a", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 14.6, "final_year_of_manufacture": 1986, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000631", "000005", "0", "2010/Sep/13 17:03", "Potterton Myson", "Potterton Myson", "Kingfisher", "cf50a", "4160161", "", "1986", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "14.6", "14.6", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 632, "brand_name": "Potterton International Heating", "model_name": "Kingfisher", "model_qualifier": "cf55", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 16.1, "final_year_of_manufacture": 1980, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000632", "000005", "0", "2010/Sep/13 17:03", "Potterton International Heating", "Potterton International Heating", "Kingfisher", "cf55", "4150108", "", "1980", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "16.1", "16.1", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 633, "brand_name": "Potterton Myson", "model_name": "Kingfisher", "model_qualifier": "cf60", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 17.5, "final_year_of_manufacture": 1986, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000633", "000005", "0", "2010/Sep/13 17:03", "Potterton Myson", "Potterton Myson", "Kingfisher", "cf60", "4160156", "", "1986", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "17.5", "17.5", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 634, "brand_name": "Potterton Myson", "model_name": "Kingfisher", "model_qualifier": "cf80", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 23.4, "final_year_of_manufacture": 1986, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000634", "000005", "0", "2010/Sep/13 17:03", "Potterton Myson", "Potterton Myson", "Kingfisher", "cf80", "4160139", "", "1986", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "23.4", "23.4", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 635, "brand_name": "Potterton Myson", "model_name": "Kingfisher", "model_qualifier": "rs100", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 29.3, "final_year_of_manufacture": 1986, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000635", "000005", "0", "2010/Sep/13 17:03", "Potterton Myson", "Potterton Myson", "Kingfisher", "rs100", "4160159", "", "1986", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "29.3", "29.3", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 636, "brand_name": "Potterton International Heating", "model_name": "Kingfisher", "model_qualifier": "rs50", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 13.5, "final_year_of_manufacture": 1986, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000636", "000005", "0", "2010/Sep/13 17:03", "Potterton International Heating", "Potterton International Heating", "Kingfisher", "rs50", "4160149", "", "1986", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "13.5", "13.5", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 637, "brand_name": "Potterton Myson", "model_name": "Kingfisher", "model_qualifier": "rs60", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 17.6, "final_year_of_manufacture": 1986, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000637", "000005", "0", "2010/Sep/13 17:03", "Potterton Myson", "Potterton Myson", "Kingfisher", "rs60", "4160137", "", "1986", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "17.6", "17.6", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 638, "brand_name": "Potterton Myson", "model_name": "Kingfisher", "model_qualifier": "rs80", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 23.4, "final_year_of_manufacture": 1986, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000638", "000005", "0", "2010/Sep/13 17:03", "Potterton Myson", "Potterton Myson", "Kingfisher", "rs80", "4160141", "", "1986", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "23.4", "23.4", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 639, "brand_name": "Potterton International Heating", "model_name": "Kingfisher 2", "model_qualifier": "cf100", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 29.3, "final_year_of_manufacture": 1998, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000639", "000005", "0", "2010/Sep/13 17:03", "Potterton International Heating", "Potterton International Heating", "Kingfisher 2", "cf100", "4160711", "", "1998", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "29.3", "29.3", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 640, "brand_name": "Potterton International Heating", "model_name": "Kingfisher 2", "model_qualifier": "cf125", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 36.6, "final_year_of_manufacture": 1998, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000640", "000005", "0", "2010/Sep/13 17:03", "Potterton International Heating", "Potterton International Heating", "Kingfisher 2", "cf125", "4160715", "", "1998", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "36.6", "36.6", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 641, "brand_name": "Potterton Myson", "model_name": "Kingfisher 2", "model_qualifier": "cf150", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 44.0, "final_year_of_manufacture": 1998, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000641", "000005", "0", "2010/Sep/13 17:03", "Potterton Myson", "Potterton Myson", "Kingfisher 2", "cf150", "4160716", "", "1998", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "44", "44", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 642, "brand_name": "Potterton International Heating", "model_name": "Kingfisher 2", "model_qualifier": "cf220", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 64.5, "final_year_of_manufacture": 1998, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000642", "000005", "0", "2010/Sep/13 17:03", "Potterton International Heating", "Potterton International Heating", "Kingfisher 2", "cf220", "", "", "1998", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "64.5", "64.5", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 643, "brand_name": "Potterton International Heating", "model_name": "Kingfisher 2", "model_qualifier": "cf40", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 11.7, "final_year_of_manufacture": 1998, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000643", "000005", "0", "2010/Sep/13 17:03", "Potterton International Heating", "Potterton International Heating", "Kingfisher 2", "cf40", "4160707", "", "1998", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "11.7", "11.7", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 644, "brand_name": "Potterton International Heating", "model_name": "Kingfisher 2", "model_qualifier": "cf50", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 14.6, "final_year_of_manufacture": 1998, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000644", "000005", "0", "2010/Sep/13 17:03", "Potterton International Heating", "Potterton International Heating", "Kingfisher 2", "cf50", "4160708", "", "1998", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "14.6", "14.6", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 645, "brand_name": "Potterton International Heating", "model_name": "Kingfisher 2", "model_qualifier": "cf60", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 17.5, "final_year_of_manufacture": 1998, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000645", "000005", "0", "2010/Sep/13 17:03", "Potterton International Heating", "Potterton International Heating", "Kingfisher 2", "cf60", "4160709", "", "1998", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "17.5", "17.5", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 646, "brand_name": "Potterton International Heating", "model_name": "Kingfisher 2", "model_qualifier": "cf80", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 23.4, "final_year_of_manufacture": 1998, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000646", "000005", "0", "2010/Sep/13 17:03", "Potterton International Heating", "Potterton International Heating", "Kingfisher 2", "cf80", "4160710", "", "1998", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "23.4", "23.4", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 647, "brand_name": "Potterton International Heating", "model_name": "Kingfisher 2", "model_qualifier": "rs100", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 29.3, "final_year_of_manufacture": 1998, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000647", "000005", "0", "2010/Sep/13 17:03", "Potterton International Heating", "Potterton International Heating", "Kingfisher 2", "rs100", "4160721", "", "1998", "1", "1", "1", "1", "0", "", "", "1", "2", "1", "29.3", "29.3", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 648, "brand_name": "Potterton Myson", "model_name": "Kingfisher 2", "model_qualifier": "rs40", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 11.7, "final_year_of_manufacture": 1998, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000648", "000005", "0", "2010/Sep/13 17:03", "Potterton Myson", "Potterton Myson", "Kingfisher 2", "rs40", "4160717", "", "1998", "1", "1", "1", "1", "0", "", "", "1", "2", "1", "11.7", "11.7", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 649, "brand_name": "Potterton International Heating", "model_name": "Kingfisher 2", "model_qualifier": "rs50", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 14.7, "final_year_of_manufacture": 1998, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000649", "000005", "0", "2010/Sep/13 17:03", "Potterton International Heating", "Potterton International Heating", "Kingfisher 2", "rs50", "4160718", "", "1998", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "14.7", "14.7", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 650, "brand_name": "Potterton International Heating", "model_name": "Kingfisher 2", "model_qualifier": "rs60", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 17.6, "final_year_of_manufacture": 1998, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000650", "000005", "0", "2010/Sep/13 17:03", "Potterton International Heating", "Potterton International Heating", "Kingfisher 2", "rs60", "4160719", "", "1998", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "17.6", "17.6", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 651, "brand_name": "Potterton International Heating", "model_name": "Kingfisher 2", "model_qualifier": "rs80", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 23.5, "final_year_of_manufacture": 1998, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000651", "000005", "0", "2010/Sep/13 17:03", "Potterton International Heating", "Potterton International Heating", "Kingfisher 2", "rs80", "4160720", "", "1998", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "23.5", "23.5", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 652, "brand_name": "Potterton International Heating", "model_name": "Lynx", "model_qualifier": "2", "winter_efficiency_pct": 71.0, "summer_efficiency_pct": 61.0, "comparative_hot_water_efficiency_pct": 42.8, "output_kw_max": 23.45, "final_year_of_manufacture": 1995, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000652", "000005", "0", "2010/Sep/13 17:03", "Potterton International Heating", "Potterton International Heating", "Lynx", "2", "4759008", "", "1995", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "23.45", "23.45", "", "", "71.0", "61.0", "", "42.8", "", "3", "", "", "0", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 653, "brand_name": "Potterton International Heating", "model_name": "Lynx", "model_qualifier": "electronic", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 57.0, "comparative_hot_water_efficiency_pct": 39.7, "output_kw_max": 23.45, "final_year_of_manufacture": 1972, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000653", "000005", "0", "2010/Sep/13 17:03", "Potterton International Heating", "Potterton International Heating", "Lynx", "electronic", "4759002", "", "1972", "1", "0", "0", "2", "0", "", "", "1", "2", "1", "23.45", "23.45", "", "", "66.0", "57.0", "", "39.7", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 654, "brand_name": "Potterton International Heating", "model_name": "Netaheat Electronic", "model_qualifier": "16/22e", "winter_efficiency_pct": 69.0, "summer_efficiency_pct": 59.0, "comparative_hot_water_efficiency_pct": 43.0, "output_kw_max": 22.0, "final_year_of_manufacture": 1983, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000654", "000005", "0", "2010/Sep/13 17:03", "Potterton International Heating", "Potterton International Heating", "Netaheat Electronic", "16/22e", "4160163", "", "1983", "1", "0", "0", "1", "0", "", "", "1", "2", "2", "22", "22", "", "", "69.0", "59.0", "", "43.0", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 655, "brand_name": "Potterton International Heating", "model_name": "Netaheat", "model_qualifier": "mk2f10-16bf", "winter_efficiency_pct": 69.0, "summer_efficiency_pct": 59.0, "comparative_hot_water_efficiency_pct": 43.0, "output_kw_max": 16.1, "final_year_of_manufacture": 1984, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000655", "000005", "0", "2010/Sep/13 17:03", "Potterton International Heating", "Potterton International Heating", "Netaheat", "mk2f10-16bf", "4160134", "", "1984", "1", "0", "0", "1", "0", "", "", "1", "2", "2", "16.1", "16.1", "", "", "69.0", "59.0", "", "43.0", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 656, "brand_name": "Potterton International Heating", "model_name": "Netaheat", "model_qualifier": "mk2f16-22bf", "winter_efficiency_pct": 69.0, "summer_efficiency_pct": 59.0, "comparative_hot_water_efficiency_pct": 43.0, "output_kw_max": 22.0, "final_year_of_manufacture": 1984, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000656", "000005", "0", "2010/Sep/13 17:03", "Potterton International Heating", "Potterton International Heating", "Netaheat", "mk2f16-22bf", "4160135", "", "1984", "1", "0", "0", "1", "0", "", "", "1", "2", "2", "22", "22", "", "", "69.0", "59.0", "", "43.0", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 657, "brand_name": "Potterton International Heating", "model_name": "Netaheat Electronic", "model_qualifier": "10/16", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 16.0, "final_year_of_manufacture": 1988, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000657", "000005", "0", "2010/Sep/13 17:03", "Potterton International Heating", "Potterton International Heating", "Netaheat Electronic", "10/16", "4160167", "", "1988", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "16", "16", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 658, "brand_name": "Potterton Myson", "model_name": "Netaheat Electronic", "model_qualifier": "10/16e", "winter_efficiency_pct": 69.0, "summer_efficiency_pct": 59.0, "comparative_hot_water_efficiency_pct": 43.0, "output_kw_max": 16.1, "final_year_of_manufacture": 1988, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000658", "000005", "0", "2010/Sep/13 17:03", "Potterton Myson", "Potterton Myson", "Netaheat Electronic", "10/16e", "4160162", "", "1988", "1", "0", "0", "1", "0", "", "", "1", "2", "2", "16.1", "16.1", "", "", "69.0", "59.0", "", "43.0", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 659, "brand_name": "Potterton Myson", "model_name": "Netaheat Electronic", "model_qualifier": "16/22", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 22.0, "final_year_of_manufacture": 1988, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000659", "000005", "0", "2010/Sep/13 17:03", "Potterton Myson", "Potterton Myson", "Netaheat Electronic", "16/22", "4160166", "", "1988", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "22", "22", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 660, "brand_name": "Potterton International Heating", "model_name": "Netaheat Electronic", "model_qualifier": "6/10", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 10.3, "final_year_of_manufacture": 1988, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000660", "000005", "0", "2010/Sep/13 17:03", "Potterton International Heating", "Potterton International Heating", "Netaheat Electronic", "6/10", "4160168", "", "1988", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "10.3", "10.3", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 676, "brand_name": "Potterton Myson", "model_name": "Rs38/11", "model_qualifier": "rs38/11", "winter_efficiency_pct": 56.0, "summer_efficiency_pct": 46.0, "comparative_hot_water_efficiency_pct": 33.5, "output_kw_max": 10.56, "final_year_of_manufacture": 1976, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000676", "000005", "0", "2010/Sep/13 17:03", "Potterton Myson", "Potterton Myson", "Rs38/11", "rs38/11", "4159529", "", "1976", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "10.56", "10.56", "", "", "56.0", "46.0", "", "33.5", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 677, "brand_name": "Potterton Myson", "model_name": "Rs50/15", "model_qualifier": "rs50/15", "winter_efficiency_pct": 56.0, "summer_efficiency_pct": 46.0, "comparative_hot_water_efficiency_pct": 33.5, "output_kw_max": 13.5, "final_year_of_manufacture": 1976, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000677", "000005", "0", "2010/Sep/13 17:03", "Potterton Myson", "Potterton Myson", "Rs50/15", "rs50/15", "4159530", "", "1976", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "13.5", "13.5", "", "", "56.0", "46.0", "", "33.5", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 678, "brand_name": "Potterton Myson", "model_name": "Rs70/21", "model_qualifier": "rs70/21", "winter_efficiency_pct": 56.0, "summer_efficiency_pct": 46.0, "comparative_hot_water_efficiency_pct": 33.5, "output_kw_max": 19.3, "final_year_of_manufacture": 1973, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000678", "000005", "0", "2010/Sep/13 17:03", "Potterton Myson", "Potterton Myson", "Rs70/21", "rs70/21", "4159531", "", "1973", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "19.3", "19.3", "", "", "56.0", "46.0", "", "33.5", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 679, "brand_name": "Potterton International Heating", "model_name": "Rs70/21", "model_qualifier": "rs70/21", "winter_efficiency_pct": 56.0, "summer_efficiency_pct": 46.0, "comparative_hot_water_efficiency_pct": 33.5, "output_kw_max": 19.3, "final_year_of_manufacture": 1979, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000679", "000005", "0", "2010/Sep/13 17:03", "Potterton International Heating", "Potterton International Heating", "Rs70/21", "rs70/21", "4159501", "", "1979", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "19.3", "19.3", "", "", "56.0", "46.0", "", "33.5", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 680, "brand_name": "Potterton International Heating", "model_name": "Rs90/26", "model_qualifier": "rs90/26", "winter_efficiency_pct": 56.0, "summer_efficiency_pct": 46.0, "comparative_hot_water_efficiency_pct": 33.5, "output_kw_max": 28.2, "final_year_of_manufacture": 1976, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000680", "000005", "0", "2010/Sep/13 17:03", "Potterton International Heating", "Potterton International Heating", "Rs90/26", "rs90/26", "4159532", "", "1976", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "28.2", "28.2", "", "", "56.0", "46.0", "", "33.5", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 682, "brand_name": "Potterton International Heating", "model_name": "Tattler", "model_qualifier": "rs46", "winter_efficiency_pct": 56.0, "summer_efficiency_pct": 46.0, "comparative_hot_water_efficiency_pct": 33.5, "output_kw_max": 13.5, "final_year_of_manufacture": 1979, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000682", "000005", "0", "2010/Sep/13 17:03", "Potterton International Heating", "Potterton International Heating", "Tattler", "rs46", "4160109", "", "1979", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "13.5", "13.5", "", "", "56.0", "46.0", "", "33.5", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 696, "brand_name": "Myson Combustion Products", "model_name": "Velaire Vitesse", "model_qualifier": "40/50 B", "winter_efficiency_pct": 70.0, "summer_efficiency_pct": 58.0, "comparative_hot_water_efficiency_pct": 42.6, "output_kw_max": 14.65, "final_year_of_manufacture": 1997, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000696", "000005", "0", "2010/Sep/13 17:03", "Myson Combustion Products", "Myson Combustion Products", "Velaire Vitesse", "40/50 B", "", "", "1997", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "11.72", "14.65", "", "", "70.0", "58.0", "", "42.6", "", "3", "", "", "0", "0", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 697, "brand_name": "Myson Combustion Products", "model_name": "Velaire Vitesse", "model_qualifier": "50/60 B", "winter_efficiency_pct": 70.0, "summer_efficiency_pct": 58.0, "comparative_hot_water_efficiency_pct": 42.6, "output_kw_max": 17.58, "final_year_of_manufacture": 1997, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000697", "000005", "0", "2010/Sep/13 17:03", "Myson Combustion Products", "Myson Combustion Products", "Velaire Vitesse", "50/60 B", "", "", "1997", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "14.65", "17.58", "", "", "70.0", "58.0", "", "42.6", "", "3", "", "", "0", "0", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 698, "brand_name": "Myson Combustion Products", "model_name": "Velaire Vitesse", "model_qualifier": "60/80 B", "winter_efficiency_pct": 70.0, "summer_efficiency_pct": 58.0, "comparative_hot_water_efficiency_pct": 42.6, "output_kw_max": 23.45, "final_year_of_manufacture": 1997, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000698", "000005", "0", "2010/Sep/13 17:03", "Myson Combustion Products", "Myson Combustion Products", "Velaire Vitesse", "60/80 B", "", "", "1997", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "17.58", "23.45", "", "", "70.0", "58.0", "", "42.6", "", "3", "", "", "0", "0", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 699, "brand_name": "Myson Combustion Products", "model_name": "Velaire Vitesse", "model_qualifier": "80/100 B", "winter_efficiency_pct": 70.0, "summer_efficiency_pct": 58.0, "comparative_hot_water_efficiency_pct": 42.6, "output_kw_max": 29.31, "final_year_of_manufacture": 1997, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000699", "000005", "0", "2010/Sep/13 17:03", "Myson Combustion Products", "Myson Combustion Products", "Velaire Vitesse", "80/100 B", "", "", "1997", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "23.45", "29.31", "", "", "70.0", "58.0", "", "42.6", "", "3", "", "", "0", "0", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 700, "brand_name": "Myson Combustion Products", "model_name": "Velaire Vitesse", "model_qualifier": "100/130 B", "winter_efficiency_pct": 70.0, "summer_efficiency_pct": 58.0, "comparative_hot_water_efficiency_pct": 42.6, "output_kw_max": 38.1, "final_year_of_manufacture": 1998, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000700", "000005", "0", "2010/Sep/13 17:03", "Myson Combustion Products", "Myson Combustion Products", "Velaire Vitesse", "100/130 B", "", "", "1998", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "29.3", "38.1", "", "", "70.0", "58.0", "", "42.6", "", "3", "", "", "0", "0", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 701, "brand_name": "Myson Combustion Products", "model_name": "Velaire Vitesse", "model_qualifier": "130/170 B", "winter_efficiency_pct": 70.0, "summer_efficiency_pct": 58.0, "comparative_hot_water_efficiency_pct": 42.6, "output_kw_max": 49.8, "final_year_of_manufacture": 1998, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000701", "000005", "0", "2010/Sep/13 17:03", "Myson Combustion Products", "Myson Combustion Products", "Velaire Vitesse", "130/170 B", "", "", "1998", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "38.1", "49.8", "", "", "70.0", "58.0", "", "42.6", "", "3", "", "", "0", "0", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 702, "brand_name": "Myson Combustion Products", "model_name": "Velaire Vitesse", "model_qualifier": "40/50 C", "winter_efficiency_pct": 70.0, "summer_efficiency_pct": 58.0, "comparative_hot_water_efficiency_pct": 42.6, "output_kw_max": 14.65, "final_year_of_manufacture": 1997, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000702", "000005", "0", "2010/Sep/13 17:03", "Myson Combustion Products", "Myson Combustion Products", "Velaire Vitesse", "40/50 C", "", "", "1997", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "11.72", "14.65", "", "", "70.0", "58.0", "", "42.6", "", "3", "", "", "0", "0", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 703, "brand_name": "Myson Combustion Products", "model_name": "Velaire Vitesse", "model_qualifier": "50/60 C", "winter_efficiency_pct": 70.0, "summer_efficiency_pct": 58.0, "comparative_hot_water_efficiency_pct": 42.6, "output_kw_max": 17.58, "final_year_of_manufacture": 1997, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000703", "000005", "0", "2010/Sep/13 17:03", "Myson Combustion Products", "Myson Combustion Products", "Velaire Vitesse", "50/60 C", "", "", "1997", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "14.65", "17.58", "", "", "70.0", "58.0", "", "42.6", "", "3", "", "", "0", "0", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 704, "brand_name": "Myson Combustion Products", "model_name": "Velaire Vitesse", "model_qualifier": "60/80 C", "winter_efficiency_pct": 70.0, "summer_efficiency_pct": 58.0, "comparative_hot_water_efficiency_pct": 42.6, "output_kw_max": 23.45, "final_year_of_manufacture": 1997, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000704", "000005", "0", "2010/Sep/13 17:03", "Myson Combustion Products", "Myson Combustion Products", "Velaire Vitesse", "60/80 C", "", "", "1997", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "17.58", "23.45", "", "", "70.0", "58.0", "", "42.6", "", "3", "", "", "0", "0", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 705, "brand_name": "Myson Combustion Products", "model_name": "Velaire Vitesse", "model_qualifier": "80/100 C", "winter_efficiency_pct": 70.0, "summer_efficiency_pct": 58.0, "comparative_hot_water_efficiency_pct": 42.6, "output_kw_max": 29.31, "final_year_of_manufacture": 1997, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000705", "000005", "0", "2010/Sep/13 17:03", "Myson Combustion Products", "Myson Combustion Products", "Velaire Vitesse", "80/100 C", "", "", "1997", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "23.45", "29.31", "", "", "70.0", "58.0", "", "42.6", "", "3", "", "", "0", "0", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 706, "brand_name": "Myson Combustion Products", "model_name": "Velaire Vitesse", "model_qualifier": "100/130 C", "winter_efficiency_pct": 70.0, "summer_efficiency_pct": 58.0, "comparative_hot_water_efficiency_pct": 42.6, "output_kw_max": 38.1, "final_year_of_manufacture": 1998, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000706", "000005", "0", "2010/Sep/13 17:03", "Myson Combustion Products", "Myson Combustion Products", "Velaire Vitesse", "100/130 C", "", "", "1998", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "29.3", "38.1", "", "", "70.0", "58.0", "", "42.6", "", "3", "", "", "0", "0", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 707, "brand_name": "Myson Combustion Products", "model_name": "Velaire Vitesse", "model_qualifier": "130/170 C", "winter_efficiency_pct": 70.0, "summer_efficiency_pct": 58.0, "comparative_hot_water_efficiency_pct": 42.6, "output_kw_max": 49.8, "final_year_of_manufacture": 1998, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000707", "000005", "0", "2010/Sep/13 17:03", "Myson Combustion Products", "Myson Combustion Products", "Velaire Vitesse", "130/170 C", "", "", "1998", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "38.1", "49.8", "", "", "70.0", "58.0", "", "42.6", "", "3", "", "", "0", "0", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 708, "brand_name": "Myson Combustion Products", "model_name": "Velaire Vitesse", "model_qualifier": "170/250 C", "winter_efficiency_pct": 70.0, "summer_efficiency_pct": 58.0, "comparative_hot_water_efficiency_pct": 42.6, "output_kw_max": null, "final_year_of_manufacture": 1997, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000708", "000005", "0", "2010/Sep/13 17:03", "Myson Combustion Products", "Myson Combustion Products", "Velaire Vitesse", "170/250 C", "", "", "1997", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "49.8", ">70kW", "", "", "70.0", "58.0", "", "42.6", "", "3", "", "", "0", "0", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 710, "brand_name": "Potterton International Heating", "model_name": "BOA", "model_qualifier": "68", "winter_efficiency_pct": 65.0, "summer_efficiency_pct": 53.0, "comparative_hot_water_efficiency_pct": 38.9, "output_kw_max": 19.9, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000710", "000005", "0", "2010/Sep/13 17:03", "Potterton International Heating", "Potterton International Heating", "BOA", "68", "", "", "obsolete", "4", "0", "0", "1", "0", "", "", "1", "2", "2", "19.9", "19.9", "", "", "65.0", "53.0", "", "38.9", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 711, "brand_name": "Potterton International Heating", "model_name": "BOA", "model_qualifier": "148", "winter_efficiency_pct": 65.0, "summer_efficiency_pct": 53.0, "comparative_hot_water_efficiency_pct": 38.9, "output_kw_max": 36.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000711", "000005", "0", "2010/Sep/13 17:03", "Potterton International Heating", "Potterton International Heating", "BOA", "148", "", "", "obsolete", "4", "0", "0", "1", "0", "", "", "1", "2", "2", "36", "36", "", "", "65.0", "53.0", "", "38.9", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 713, "brand_name": "Myson Combustion Products", "model_name": "Wallflame", "model_qualifier": "60", "winter_efficiency_pct": 65.0, "summer_efficiency_pct": 53.0, "comparative_hot_water_efficiency_pct": 38.9, "output_kw_max": 17.6, "final_year_of_manufacture": 1980, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000713", "000005", "0", "2010/Sep/13 17:03", "Myson Combustion Products", "Myson Combustion Products", "Wallflame", "60", "", "", "1980", "4", "0", "0", "1", "0", "", "", "1", "1", "1", "17.6", "17.6", "", "", "65.0", "53.0", "", "38.9", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 714, "brand_name": "Potterton International Heating", "model_name": "KOA", "model_qualifier": "60/18 SN", "winter_efficiency_pct": 65.0, "summer_efficiency_pct": 53.0, "comparative_hot_water_efficiency_pct": 38.9, "output_kw_max": 17.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000714", "000005", "0", "2010/Sep/13 17:03", "Potterton International Heating", "Potterton International Heating", "KOA", "60/18 SN", "", "", "obsolete", "4", "0", "0", "1", "0", "", "", "1", "2", "2", "17.6", "17.6", "", "", "65.0", "53.0", "", "38.9", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 715, "brand_name": "Potterton International Heating", "model_name": "KOA", "model_qualifier": "75/22 SN", "winter_efficiency_pct": 65.0, "summer_efficiency_pct": 53.0, "comparative_hot_water_efficiency_pct": 38.9, "output_kw_max": 22.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000715", "000005", "0", "2010/Sep/13 17:03", "Potterton International Heating", "Potterton International Heating", "KOA", "75/22 SN", "", "", "obsolete", "4", "0", "0", "1", "0", "", "", "1", "2", "2", "22", "22", "", "", "65.0", "53.0", "", "38.9", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 716, "brand_name": "Potterton International Heating", "model_name": "KOA", "model_qualifier": "90/26 SN", "winter_efficiency_pct": 65.0, "summer_efficiency_pct": 53.0, "comparative_hot_water_efficiency_pct": 38.9, "output_kw_max": 26.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000716", "000005", "0", "2010/Sep/13 17:03", "Potterton International Heating", "Potterton International Heating", "KOA", "90/26 SN", "", "", "obsolete", "4", "0", "0", "1", "0", "", "", "1", "2", "2", "26.4", "26.4", "", "", "65.0", "53.0", "", "38.9", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 717, "brand_name": "Myson Combustion Products", "model_name": "Wallflame", "model_qualifier": "80", "winter_efficiency_pct": 65.0, "summer_efficiency_pct": 53.0, "comparative_hot_water_efficiency_pct": 38.9, "output_kw_max": 23.4, "final_year_of_manufacture": 1980, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000717", "000005", "0", "2010/Sep/13 17:03", "Myson Combustion Products", "Myson Combustion Products", "Wallflame", "80", "", "", "1980", "4", "0", "0", "1", "0", "", "", "1", "1", "1", "23.4", "23.4", "", "", "65.0", "53.0", "", "38.9", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 731, "brand_name": "Saunier Duval", "model_name": "500", "model_qualifier": "30b", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 8.79, "final_year_of_manufacture": 1992, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000731", "000020", "0", "2010/Sep/13 17:03", "Saunier Duval", "Saunier Duval", "500", "30b", "4192002", "", "1992", "1", "2", "0", "1", "0", "", "", "1", "2", "1", "8.79", "8.79", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 732, "brand_name": "Saunier Duval", "model_name": "500", "model_qualifier": "30c", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 8.79, "final_year_of_manufacture": 1992, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000732", "000020", "0", "2010/Sep/13 17:03", "Saunier Duval", "Saunier Duval", "500", "30c", "4192007", "", "1992", "1", "2", "0", "1", "0", "", "", "1", "1", "1", "8.79", "8.79", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 733, "brand_name": "Saunier Duval", "model_name": "500", "model_qualifier": "30f", "winter_efficiency_pct": 69.0, "summer_efficiency_pct": 59.0, "comparative_hot_water_efficiency_pct": 43.0, "output_kw_max": 8.79, "final_year_of_manufacture": 1992, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000733", "000020", "0", "2010/Sep/13 17:03", "Saunier Duval", "Saunier Duval", "500", "30f", "4192011", "", "1992", "1", "2", "0", "1", "0", "", "", "1", "2", "2", "8.79", "8.79", "", "", "69.0", "59.0", "", "43.0", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 734, "brand_name": "Saunier Duval", "model_name": "500", "model_qualifier": "40b", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 11.72, "final_year_of_manufacture": 1992, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000734", "000020", "0", "2010/Sep/13 17:03", "Saunier Duval", "Saunier Duval", "500", "40b", "4192003", "", "1992", "1", "2", "0", "1", "0", "", "", "1", "2", "1", "11.72", "11.72", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 735, "brand_name": "Saunier Duval", "model_name": "500", "model_qualifier": "40c", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 11.72, "final_year_of_manufacture": 1992, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000735", "000020", "0", "2010/Sep/13 17:03", "Saunier Duval", "Saunier Duval", "500", "40c", "4192008", "", "1992", "1", "2", "0", "1", "0", "", "", "1", "1", "1", "11.72", "11.72", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 736, "brand_name": "Saunier Duval", "model_name": "500", "model_qualifier": "40f", "winter_efficiency_pct": 69.0, "summer_efficiency_pct": 59.0, "comparative_hot_water_efficiency_pct": 43.0, "output_kw_max": 11.72, "final_year_of_manufacture": 1992, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000736", "000020", "0", "2010/Sep/13 17:03", "Saunier Duval", "Saunier Duval", "500", "40f", "4192012", "", "1992", "1", "2", "0", "1", "0", "", "", "1", "2", "2", "11.72", "11.72", "", "", "69.0", "59.0", "", "43.0", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 737, "brand_name": "Saunier Duval", "model_name": "500", "model_qualifier": "50b", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 14.65, "final_year_of_manufacture": 1992, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000737", "000020", "0", "2010/Sep/13 17:03", "Saunier Duval", "Saunier Duval", "500", "50b", "4192004", "", "1992", "1", "2", "0", "1", "0", "", "", "1", "2", "1", "14.65", "14.65", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 738, "brand_name": "Saunier Duval", "model_name": "500", "model_qualifier": "50c", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 14.65, "final_year_of_manufacture": 1992, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000738", "000020", "0", "2010/Sep/13 17:03", "Saunier Duval", "Saunier Duval", "500", "50c", "4192009", "", "1992", "1", "2", "0", "1", "0", "", "", "1", "1", "1", "14.65", "14.65", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 739, "brand_name": "Saunier Duval", "model_name": "500", "model_qualifier": "50f", "winter_efficiency_pct": 69.0, "summer_efficiency_pct": 59.0, "comparative_hot_water_efficiency_pct": 43.0, "output_kw_max": 14.65, "final_year_of_manufacture": 1992, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000739", "000020", "0", "2010/Sep/13 17:03", "Saunier Duval", "Saunier Duval", "500", "50f", "4192013", "", "1992", "1", "2", "0", "1", "0", "", "", "1", "2", "2", "14.65", "14.65", "", "", "69.0", "59.0", "", "43.0", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 740, "brand_name": "Saunier Duval", "model_name": "500", "model_qualifier": "60b", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 17.59, "final_year_of_manufacture": 1992, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000740", "000020", "0", "2010/Sep/13 17:03", "Saunier Duval", "Saunier Duval", "500", "60b", "4192005", "", "1992", "1", "2", "0", "1", "0", "", "", "1", "2", "1", "17.59", "17.59", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 741, "brand_name": "Saunier Duval", "model_name": "500", "model_qualifier": "60c", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 17.59, "final_year_of_manufacture": 1992, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000741", "000020", "0", "2010/Sep/13 17:03", "Saunier Duval", "Saunier Duval", "500", "60c", "4192010", "", "1992", "1", "2", "0", "1", "0", "", "", "1", "1", "1", "17.59", "17.59", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 742, "brand_name": "Saunier Duval", "model_name": "500", "model_qualifier": "60f", "winter_efficiency_pct": 69.0, "summer_efficiency_pct": 59.0, "comparative_hot_water_efficiency_pct": 43.0, "output_kw_max": 17.59, "final_year_of_manufacture": 1992, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000742", "000020", "0", "2010/Sep/13 17:03", "Saunier Duval", "Saunier Duval", "500", "60f", "4192014", "", "1992", "1", "2", "0", "1", "0", "", "", "1", "2", "2", "17.59", "17.59", "", "", "69.0", "59.0", "", "43.0", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 743, "brand_name": "Saunier Duval", "model_name": "500", "model_qualifier": "80b", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 23.45, "final_year_of_manufacture": 1992, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000743", "000020", "0", "2010/Sep/13 17:03", "Saunier Duval", "Saunier Duval", "500", "80b", "4192006", "", "1992", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "23.45", "23.45", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 744, "brand_name": "Saunier Duval", "model_name": "Sd", "model_qualifier": "623", "winter_efficiency_pct": 71.0, "summer_efficiency_pct": 62.0, "comparative_hot_water_efficiency_pct": 43.2, "output_kw_max": 23.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000744", "000206", "0", "2010/Sep/13 17:03", "Saunier Duval", "Saunier Duval", "Sd", "623", "4792001", "", "obsolete", "1", "0", "0", "2", "0", "", "", "1", "2", "2", "23.3", "23.3", "", "", "71.0", "62.0", "", "43.2", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 745, "brand_name": "Saunier Duval", "model_name": "System 400", "model_qualifier": "30", "winter_efficiency_pct": 69.0, "summer_efficiency_pct": 59.0, "comparative_hot_water_efficiency_pct": 43.0, "output_kw_max": 8.8, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000745", "000206", "0", "2010/Sep/13 17:03", "Saunier Duval", "Saunier Duval", "System 400", "30", "4192017", "", "obsolete", "1", "0", "0", "1", "0", "", "", "1", "2", "2", "8.8", "8.8", "", "", "69.0", "59.0", "", "43.0", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 746, "brand_name": "Saunier Duval", "model_name": "System 400", "model_qualifier": "40", "winter_efficiency_pct": 69.0, "summer_efficiency_pct": 59.0, "comparative_hot_water_efficiency_pct": 43.0, "output_kw_max": 11.7, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000746", "000206", "0", "2010/Sep/13 17:03", "Saunier Duval", "Saunier Duval", "System 400", "40", "4192018", "", "obsolete", "1", "0", "0", "1", "0", "", "", "1", "2", "2", "11.7", "11.7", "", "", "69.0", "59.0", "", "43.0", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 747, "brand_name": "Saunier Duval", "model_name": "System 400", "model_qualifier": "55", "winter_efficiency_pct": 69.0, "summer_efficiency_pct": 59.0, "comparative_hot_water_efficiency_pct": 43.0, "output_kw_max": 16.1, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000747", "000206", "0", "2010/Sep/13 17:03", "Saunier Duval", "Saunier Duval", "System 400", "55", "4192019", "", "obsolete", "1", "0", "0", "1", "0", "", "", "1", "2", "2", "16.1", "16.1", "", "", "69.0", "59.0", "", "43.0", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 748, "brand_name": "Saunier Duval", "model_name": "System 400", "model_qualifier": "65", "winter_efficiency_pct": 69.0, "summer_efficiency_pct": 59.0, "comparative_hot_water_efficiency_pct": 43.0, "output_kw_max": 19.1, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000748", "000206", "0", "2010/Sep/13 17:03", "Saunier Duval", "Saunier Duval", "System 400", "65", "4192020", "", "obsolete", "1", "0", "0", "1", "0", "", "", "1", "2", "2", "19.1", "19.1", "", "", "69.0", "59.0", "", "43.0", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 749, "brand_name": "Saunier Duval", "model_name": "System 400", "model_qualifier": "80", "winter_efficiency_pct": 69.0, "summer_efficiency_pct": 59.0, "comparative_hot_water_efficiency_pct": 43.0, "output_kw_max": 23.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000749", "000206", "0", "2010/Sep/13 17:03", "Saunier Duval", "Saunier Duval", "System 400", "80", "4192021", "", "obsolete", "1", "0", "0", "1", "0", "", "", "1", "2", "2", "23.4", "23.4", "", "", "69.0", "59.0", "", "43.0", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 750, "brand_name": "Saunier Duval", "model_name": "Thelia", "model_qualifier": "23", "winter_efficiency_pct": 71.0, "summer_efficiency_pct": 62.0, "comparative_hot_water_efficiency_pct": 43.2, "output_kw_max": 23.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000750", "000206", "0", "2010/Sep/13 17:03", "Saunier Duval", "Saunier Duval", "Thelia", "23", "", "", "obsolete", "1", "0", "0", "2", "0", "", "", "1", "2", "2", "23", "23", "", "", "71.0", "62.0", "", "43.2", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 751, "brand_name": "Saunier Duval", "model_name": "Thelia", "model_qualifier": "23E", "winter_efficiency_pct": 71.0, "summer_efficiency_pct": 62.0, "comparative_hot_water_efficiency_pct": 43.2, "output_kw_max": 23.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000751", "000206", "0", "2010/Sep/13 17:03", "Saunier Duval", "Saunier Duval", "Thelia", "23E", "", "", "obsolete", "1", "0", "0", "2", "0", "", "", "1", "2", "2", "23", "23", "", "", "71.0", "62.0", "", "43.2", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 752, "brand_name": "Saunier Duval", "model_name": "Thelia", "model_qualifier": "30", "winter_efficiency_pct": 71.0, "summer_efficiency_pct": 62.0, "comparative_hot_water_efficiency_pct": 43.2, "output_kw_max": 30.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000752", "000206", "0", "2010/Sep/13 17:03", "Saunier Duval", "Saunier Duval", "Thelia", "30", "", "", "obsolete", "1", "0", "0", "2", "0", "", "", "1", "2", "2", "30", "30", "", "", "71.0", "62.0", "", "43.2", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 753, "brand_name": "Saunier Duval", "model_name": "Themis", "model_qualifier": "23", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 57.0, "comparative_hot_water_efficiency_pct": 39.7, "output_kw_max": 23.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000753", "000206", "0", "2010/Sep/13 17:03", "Saunier Duval", "Saunier Duval", "Themis", "23", "", "", "obsolete", "1", "0", "0", "2", "0", "", "", "1", "1", "1", "23", "23", "", "", "66.0", "57.0", "", "39.7", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 754, "brand_name": "Saunier Duval", "model_name": "Sd", "model_qualifier": "235C", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 57.0, "comparative_hot_water_efficiency_pct": 39.7, "output_kw_max": 34.8, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000754", "000206", "0", "2010/Sep/13 17:03", "Saunier Duval", "Saunier Duval", "Sd", "235C", "", "", "obsolete", "1", "0", "0", "2", "0", "", "", "1", "1", "1", "34.8", "34.8", "", "", "66.0", "57.0", "", "39.7", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 755, "brand_name": "Saunier Duval", "model_name": "Thelia", "model_qualifier": "SB23", "winter_efficiency_pct": 71.0, "summer_efficiency_pct": 62.0, "comparative_hot_water_efficiency_pct": 43.2, "output_kw_max": null, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000755", "000206", "0", "2010/Sep/13 17:03", "Saunier Duval", "Saunier Duval", "Thelia", "SB23", "", "", "obsolete", "1", "0", "0", "2", "0", "", "", "1", "2", "2", "", "", "", "", "71.0", "62.0", "", "43.2", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 757, "brand_name": "Saunier Duval", "model_name": "Thelia", "model_qualifier": "Twin 28e", "winter_efficiency_pct": 71.0, "summer_efficiency_pct": 62.0, "comparative_hot_water_efficiency_pct": 43.2, "output_kw_max": null, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000757", "000206", "0", "2010/Sep/13 17:03", "Saunier Duval", "Saunier Duval", "Thelia", "Twin 28e", "", "", "obsolete", "1", "0", "0", "2", "0", "", "", "1", "2", "2", "", "", "", "", "71.0", "62.0", "", "43.2", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 761, "brand_name": "Sime Heating Products (UK)", "model_name": "Super 102 Deluxe", "model_qualifier": "11006", "winter_efficiency_pct": 71.0, "summer_efficiency_pct": 62.0, "comparative_hot_water_efficiency_pct": 43.2, "output_kw_max": 29.7, "final_year_of_manufacture": 1999, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000761", "000213", "0", "2010/Sep/13 17:03", "Sime Heating Products (UK)", "Sime Heating Products (UK)", "Super 102 Deluxe", "11006", "", "1996", "1999", "1", "2", "0", "2", "0", "", "", "1", "2", "2", "15.3", "29.7", "", "", "71.0", "62.0", "", "43.2", "", "3", "", "", "0", "0", "0", "210", "2", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 763, "brand_name": "Sime Heating Products (UK)", "model_name": "Friendly", "model_qualifier": "11010", "winter_efficiency_pct": 71.0, "summer_efficiency_pct": 62.0, "comparative_hot_water_efficiency_pct": 43.2, "output_kw_max": 23.4, "final_year_of_manufacture": 1999, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000763", "000213", "0", "2010/Sep/13 17:03", "Sime Heating Products (UK)", "Sime Heating Products (UK)", "Friendly", "11010", "", "1996", "1999", "1", "2", "0", "2", "0", "", "", "1", "2", "2", "9.7", "23.4", "", "", "71.0", "62.0", "", "43.2", "", "3", "", "", "0", "2", "0", "150", "50", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 764, "brand_name": "Sime Heating Products (UK)", "model_name": "Friendly", "model_qualifier": "E", "winter_efficiency_pct": 71.0, "summer_efficiency_pct": 62.0, "comparative_hot_water_efficiency_pct": 43.2, "output_kw_max": 23.4, "final_year_of_manufacture": 1999, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000764", "000213", "0", "2010/Sep/13 17:03", "Sime Heating Products (UK)", "Sime Heating Products (UK)", "Friendly", "E", "", "1997", "1999", "1", "2", "0", "2", "0", "", "", "1", "2", "2", "9.7", "23.4", "", "", "71.0", "62.0", "", "43.2", "", "3", "", "", "0", "0", "0", "150", "2", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 766, "brand_name": "Vaillant", "model_name": "Combicompact", "model_qualifier": "vcw221h", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 57.0, "comparative_hot_water_efficiency_pct": 39.7, "output_kw_max": 22.0, "final_year_of_manufacture": 1996, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000766", "000031", "0", "2011/Jul/14 11:33", "Vaillant", "Vaillant", "Combicompact", "vcw221h", "4704414", "", "1996", "1", "0", "0", "2", "0", "", "", "1", "2", "1", "22", "22", "", "", "66.0", "57.0", "", "39.7", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 767, "brand_name": "Vaillant", "model_name": "Combicompact", "model_qualifier": "vcw240h", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 57.0, "comparative_hot_water_efficiency_pct": 39.7, "output_kw_max": 24.0, "final_year_of_manufacture": 1996, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000767", "000031", "0", "2010/Sep/13 17:03", "Vaillant", "Vaillant", "Combicompact", "vcw240h", "4704415", "", "1996", "1", "0", "0", "2", "0", "", "", "1", "1", "1", "24", "24", "", "", "66.0", "57.0", "", "39.7", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 768, "brand_name": "Vaillant", "model_name": "Combicompact", "model_qualifier": "vcw242eh", "winter_efficiency_pct": 71.0, "summer_efficiency_pct": 62.0, "comparative_hot_water_efficiency_pct": 43.2, "output_kw_max": 24.0, "final_year_of_manufacture": 1995, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000768", "000031", "0", "2010/Sep/13 17:03", "Vaillant", "Vaillant", "Combicompact", "vcw242eh", "4704413", "", "1995", "1", "0", "0", "2", "0", "", "", "1", "2", "2", "24", "24", "", "", "71.0", "62.0", "", "43.2", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 769, "brand_name": "Vaillant", "model_name": "Combicompact", "model_qualifier": "vcw280h", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 57.0, "comparative_hot_water_efficiency_pct": 39.7, "output_kw_max": 27.6, "final_year_of_manufacture": 1996, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000769", "000031", "0", "2010/Sep/13 17:03", "Vaillant", "Vaillant", "Combicompact", "vcw280h", "4704416", "", "1996", "1", "0", "0", "2", "0", "", "", "1", "1", "1", "27.6", "27.6", "", "", "66.0", "57.0", "", "39.7", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 770, "brand_name": "Vaillant", "model_name": "Combicompact", "model_qualifier": "vcw282eh", "winter_efficiency_pct": 71.0, "summer_efficiency_pct": 62.0, "comparative_hot_water_efficiency_pct": 43.2, "output_kw_max": 28.0, "final_year_of_manufacture": 1995, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000770", "000031", "0", "2010/Sep/13 17:03", "Vaillant", "Vaillant", "Combicompact", "vcw282eh", "4704418", "", "1995", "1", "0", "0", "2", "0", "", "", "1", "2", "2", "28", "28", "", "", "71.0", "62.0", "", "43.2", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 771, "brand_name": "Vaillant", "model_name": "T3Wcombi", "model_qualifier": "vcw20/1t3w", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 57.0, "comparative_hot_water_efficiency_pct": 39.7, "output_kw_max": 24.0, "final_year_of_manufacture": 1988, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000771", "000031", "0", "2010/Sep/13 17:03", "Vaillant", "Vaillant", "T3Wcombi", "vcw20/1t3w", "4704403", "", "1988", "1", "0", "0", "2", "0", "", "", "1", "1", "1", "24", "24", "", "", "66.0", "57.0", "", "39.7", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 772, "brand_name": "Vaillant", "model_name": "T3Wcombi", "model_qualifier": "vcw25/1t3w", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 57.0, "comparative_hot_water_efficiency_pct": 39.7, "output_kw_max": 26.6, "final_year_of_manufacture": 1988, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000772", "000031", "0", "2010/Sep/13 17:03", "Vaillant", "Vaillant", "T3Wcombi", "vcw25/1t3w", "4704405", "", "1988", "1", "0", "0", "2", "0", "", "", "1", "1", "1", "26.6", "26.6", "", "", "66.0", "57.0", "", "39.7", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 773, "brand_name": "Vaillant", "model_name": "T3Wcombi", "model_qualifier": "vcwsine18t3w", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 57.0, "comparative_hot_water_efficiency_pct": 39.7, "output_kw_max": 19.5, "final_year_of_manufacture": 1988, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000773", "000031", "0", "2010/Sep/13 17:03", "Vaillant", "Vaillant", "T3Wcombi", "vcwsine18t3w", "4704401", "", "1988", "1", "0", "0", "2", "0", "", "", "1", "2", "1", "19.5", "19.5", "", "", "66.0", "57.0", "", "39.7", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 774, "brand_name": "Vaillant", "model_name": "Thermocompact", "model_qualifier": "vc110h", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 10.5, "final_year_of_manufacture": 1996, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000774", "000031", "0", "2010/Sep/13 17:03", "Vaillant", "Vaillant", "Thermocompact", "vc110h", "4104401", "", "1996", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "10.5", "10.5", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 775, "brand_name": "Vaillant", "model_name": "Thermocompact", "model_qualifier": "vc180h", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 18.0, "final_year_of_manufacture": 1996, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000775", "000031", "0", "2010/Sep/13 17:03", "Vaillant", "Vaillant", "Thermocompact", "vc180h", "4104403", "", "1996", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "18", "18", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 776, "brand_name": "Vaillant", "model_name": "Thermocompact", "model_qualifier": "vc182eh", "winter_efficiency_pct": 73.0, "summer_efficiency_pct": 63.0, "comparative_hot_water_efficiency_pct": 45.9, "output_kw_max": 18.0, "final_year_of_manufacture": 1996, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000776", "000031", "0", "2015/Jul/21 14:15", "Vaillant", "Vaillant", "Thermocompact", "vc182eh", "4104404", "", "1996", "1", "0", "0", "1", "0", "", "", "1", "2", "2", "18", "18", "", "", "73.0", "63.0", "", "45.9", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 777, "brand_name": "Vaillant", "model_name": "Thermocompact", "model_qualifier": "vc221h", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 22.0, "final_year_of_manufacture": 1996, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000777", "000031", "0", "2010/Sep/13 17:03", "Vaillant", "Vaillant", "Thermocompact", "vc221h", "4104405", "", "1996", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "22", "22", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 778, "brand_name": "Vaillant", "model_name": "Thermocompact", "model_qualifier": "vc240h", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 24.0, "final_year_of_manufacture": 1996, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000778", "000031", "0", "2010/Sep/13 17:03", "Vaillant", "Vaillant", "Thermocompact", "vc240h", "4104406", "", "1996", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "24", "24", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 779, "brand_name": "Vaillant", "model_name": "Thermocompact", "model_qualifier": "vc242eh", "winter_efficiency_pct": 73.0, "summer_efficiency_pct": 63.0, "comparative_hot_water_efficiency_pct": 45.9, "output_kw_max": 24.0, "final_year_of_manufacture": 1996, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000779", "000031", "0", "2015/Jul/21 14:15", "Vaillant", "Vaillant", "Thermocompact", "vc242eh", "4104407", "", "1996", "1", "0", "0", "1", "0", "", "", "1", "2", "2", "24", "24", "", "", "73.0", "63.0", "", "45.9", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 780, "brand_name": "Vaillant", "model_name": "Thermocompact", "model_qualifier": "vc282eh", "winter_efficiency_pct": 73.0, "summer_efficiency_pct": 63.0, "comparative_hot_water_efficiency_pct": 45.9, "output_kw_max": 28.0, "final_year_of_manufacture": 1996, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000780", "000031", "0", "2015/Jul/21 14:15", "Vaillant", "Vaillant", "Thermocompact", "vc282eh", "4104410", "", "1996", "1", "0", "0", "1", "0", "", "", "1", "2", "2", "28", "28", "", "", "73.0", "63.0", "", "45.9", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 781, "brand_name": "Vaillant", "model_name": "Vkboiler", "model_qualifier": "vk35", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 35.0, "final_year_of_manufacture": 1995, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000781", "000031", "0", "2010/Sep/13 17:03", "Vaillant", "Vaillant", "Vkboiler", "vk35", "", "", "1995", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "35", "35", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 782, "brand_name": "Vaillant", "model_name": "Vkboiler", "model_qualifier": "vk41", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 41.0, "final_year_of_manufacture": 1995, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000782", "000031", "0", "2010/Sep/13 17:03", "Vaillant", "Vaillant", "Vkboiler", "vk41", "", "", "1995", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "41", "41", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 783, "brand_name": "Vaillant", "model_name": "Vkboiler", "model_qualifier": "vk48", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 46.5, "final_year_of_manufacture": 1995, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000783", "000031", "0", "2010/Sep/13 17:03", "Vaillant", "Vaillant", "Vkboiler", "vk48", "", "", "1995", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "46.5", "46.5", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 784, "brand_name": "Vaillant", "model_name": "Vkboiler", "model_qualifier": "vk58", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 58.1, "final_year_of_manufacture": 1995, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000784", "000031", "0", "2010/Sep/13 17:03", "Vaillant", "Vaillant", "Vkboiler", "vk58", "", "", "1995", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "58.1", "58.1", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 798, "brand_name": "Worcester", "model_name": "Delglo", "model_qualifier": "2bf", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 12.3, "final_year_of_manufacture": 1991, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000798", "000035", "0", "2010/Sep/13 17:03", "Worcester Heat Systems", "Worcester", "Delglo", "2bf", "4131122", "", "1991", "1", "1", "1", "1", "0", "", "", "1", "2", "1", "12.3", "12.3", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 799, "brand_name": "Worcester", "model_name": "Delglo", "model_qualifier": "2of", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 12.3, "final_year_of_manufacture": 1991, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000799", "000035", "0", "2010/Sep/13 17:03", "Worcester Heat Systems", "Worcester", "Delglo", "2of", "4131121", "", "1991", "1", "1", "1", "1", "0", "", "", "1", "2", "1", "12.3", "12.3", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 800, "brand_name": "Worcester", "model_name": "Delglo", "model_qualifier": "3bf", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 12.3, "final_year_of_manufacture": 1991, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000800", "000035", "0", "2010/Sep/13 17:03", "Worcester Heat Systems", "Worcester", "Delglo", "3bf", "4131126", "", "1991", "1", "1", "1", "1", "0", "", "", "1", "2", "1", "12.3", "12.3", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 801, "brand_name": "Worcester", "model_name": "Delglo", "model_qualifier": "3of", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 12.3, "final_year_of_manufacture": 1991, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000801", "000035", "0", "2010/Sep/13 17:03", "Worcester Heat Systems", "Worcester", "Delglo", "3of", "4131125", "", "1991", "1", "1", "1", "1", "0", "", "", "1", "2", "1", "12.3", "12.3", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 802, "brand_name": "Worcester", "model_name": "Heatslave", "model_qualifier": "9.24bf", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 39.2, "output_kw_max": 8.8, "final_year_of_manufacture": 1989, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000802", "000035", "0", "2010/Sep/13 17:03", "Worcester Heat Systems", "Worcester", "Heatslave", "9.24bf", "4731102", "", "1989", "1", "2", "1", "2", "0", "", "", "1", "2", "1", "8.8", "8.8", "", "", "66.0", "56.0", "", "39.2", "", "3", "", "", "0", "2", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 803, "brand_name": "Worcester", "model_name": "Heatslave", "model_qualifier": "9.24of", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 39.2, "output_kw_max": 24.0, "final_year_of_manufacture": 1989, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000803", "000035", "0", "2010/Sep/13 17:03", "Worcester Heat Systems", "Worcester", "Heatslave", "9.24of", "4731101", "", "1989", "1", "2", "1", "2", "0", "", "", "1", "1", "1", "24", "24", "", "", "66.0", "56.0", "", "39.2", "", "3", "", "", "0", "2", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 804, "brand_name": "Worcester", "model_name": "Heatslave", "model_qualifier": "9.24rsf", "winter_efficiency_pct": 71.0, "summer_efficiency_pct": 61.0, "comparative_hot_water_efficiency_pct": 42.8, "output_kw_max": 24.0, "final_year_of_manufacture": 1989, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000804", "000035", "0", "2010/Sep/13 17:03", "Worcester Heat Systems", "Worcester", "Heatslave", "9.24rsf", "4731103", "", "1989", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "24", "24", "", "", "71.0", "61.0", "", "42.8", "", "3", "", "", "0", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 805, "brand_name": "Worcester", "model_name": "Heatslave", "model_qualifier": "highflow3.5rsf", "winter_efficiency_pct": 73.0, "summer_efficiency_pct": 63.0, "comparative_hot_water_efficiency_pct": 45.9, "output_kw_max": 23.44, "final_year_of_manufacture": 1993, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000805", "000035", "0", "2015/Jul/21 14:15", "Worcester Heat Systems", "Worcester", "Heatslave", "highflow3.5rsf", "4131140", "", "1993", "1", "1", "1", "1", "0", "", "", "1", "2", "2", "23.44", "23.44", "", "", "73.0", "63.0", "", "45.9", "", "3", "", "", "0", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 806, "brand_name": "Worcester", "model_name": "Heatslave", "model_qualifier": "highflow4.5bf", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 22.9, "final_year_of_manufacture": 1993, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000806", "000035", "0", "2010/Sep/13 17:03", "Worcester Heat Systems", "Worcester", "Heatslave", "highflow4.5bf", "4131142", "", "1993", "1", "1", "1", "1", "0", "", "", "1", "2", "1", "22.9", "22.9", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 807, "brand_name": "Worcester", "model_name": "Heatslave", "model_qualifier": "highflow4.5of", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 22.9, "final_year_of_manufacture": 1993, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000807", "000035", "0", "2010/Sep/13 17:03", "Worcester Heat Systems", "Worcester", "Heatslave", "highflow4.5of", "4131141", "", "1993", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "22.9", "22.9", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 808, "brand_name": "Worcester", "model_name": "Heatslave", "model_qualifier": "highflowbf", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 22.9, "final_year_of_manufacture": 1990, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000808", "000035", "0", "2010/Sep/13 17:03", "Worcester Heat Systems", "Worcester", "Heatslave", "highflowbf", "4131139", "", "1990", "1", "1", "1", "1", "0", "", "", "1", "2", "1", "22.9", "22.9", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 809, "brand_name": "Worcester", "model_name": "Heatslave", "model_qualifier": "highflowof", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 22.9, "final_year_of_manufacture": 1990, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000809", "000035", "0", "2010/Sep/13 17:03", "Worcester Heat Systems", "Worcester", "Heatslave", "highflowof", "4131138", "", "1990", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "22.9", "22.9", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 810, "brand_name": "Worcester", "model_name": "Heatslave", "model_qualifier": "juniorbf", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 12.3, "final_year_of_manufacture": 1987, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000810", "000035", "0", "2010/Sep/13 17:03", "Worcester Heat Systems", "Worcester", "Heatslave", "juniorbf", "4131124", "", "1987", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "12.3", "12.3", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 811, "brand_name": "Worcester", "model_name": "Heatslave", "model_qualifier": "juniorof", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 12.3, "final_year_of_manufacture": 1987, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000811", "000035", "0", "2010/Sep/13 17:03", "Worcester Heat Systems", "Worcester", "Heatslave", "juniorof", "4131123", "", "1987", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "12.3", "12.3", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 813, "brand_name": "Worcester", "model_name": "Heatslave", "model_qualifier": "senior12bf", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 12.3, "final_year_of_manufacture": 1989, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000813", "000035", "0", "2010/Sep/13 17:03", "Worcester Heat Systems", "Worcester", "Heatslave", "senior12bf", "4131129", "", "1989", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "12.3", "12.3", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 815, "brand_name": "Worcester", "model_name": "Heatslave", "model_qualifier": "senior12of", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 12.3, "final_year_of_manufacture": 1989, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000815", "000035", "0", "2010/Sep/13 17:03", "Worcester Heat Systems", "Worcester", "Heatslave", "senior12of", "4131128", "", "1989", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "12.3", "12.3", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 817, "brand_name": "Worcester", "model_name": "Heatslave", "model_qualifier": "senior15bf", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 14.66, "final_year_of_manufacture": 1988, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000817", "000035", "0", "2010/Sep/13 17:03", "Worcester Heat Systems", "Worcester", "Heatslave", "senior15bf", "4131133", "", "1988", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "14.66", "14.66", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 819, "brand_name": "Worcester", "model_name": "Heatslave", "model_qualifier": "senior15of", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 14.66, "final_year_of_manufacture": 1988, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000819", "000035", "0", "2010/Sep/13 17:03", "Worcester Heat Systems", "Worcester", "Heatslave", "senior15of", "4131132", "", "1988", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "14.66", "14.66", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 820, "brand_name": "Worcester", "model_name": "Heatslave", "model_qualifier": "senior6bf", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 12.3, "final_year_of_manufacture": 1991, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000820", "000035", "0", "2010/Sep/13 17:03", "Worcester Heat Systems", "Worcester", "Heatslave", "senior6bf", "4131136", "", "1991", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "12.3", "12.3", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 821, "brand_name": "Worcester", "model_name": "Heatslave", "model_qualifier": "senior6of", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 12.3, "final_year_of_manufacture": 1991, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000821", "000035", "0", "2010/Sep/13 17:03", "Worcester Heat Systems", "Worcester", "Heatslave", "senior6of", "4131135", "", "1991", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "12.3", "12.3", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 822, "brand_name": "Worcester", "model_name": "Heatslave 2", "model_qualifier": "g40bf", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 11.72, "final_year_of_manufacture": 1984, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000822", "000035", "0", "2010/Sep/13 17:03", "Worcester Heat Systems", "Worcester", "Heatslave 2", "g40bf", "4131113", "", "1984", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "11.72", "11.72", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 824, "brand_name": "Worcester", "model_name": "Heatslave 2", "model_qualifier": "g40of", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 11.72, "final_year_of_manufacture": 1984, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000824", "000035", "0", "2010/Sep/13 17:03", "Worcester Heat Systems", "Worcester", "Heatslave 2", "g40of", "4131114", "", "1984", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "11.72", "11.72", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 826, "brand_name": "Worcester", "model_name": "Heatslave 2", "model_qualifier": "g50bf", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 14.66, "final_year_of_manufacture": 1984, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000826", "000035", "0", "2010/Sep/13 17:03", "Worcester Heat Systems", "Worcester", "Heatslave 2", "g50bf", "4131117", "", "1984", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "14.66", "14.66", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 828, "brand_name": "Worcester", "model_name": "Heatslave 2", "model_qualifier": "g50of", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 14.66, "final_year_of_manufacture": 1984, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000828", "000035", "0", "2010/Sep/13 17:03", "Worcester Heat Systems", "Worcester", "Heatslave 2", "g50of", "4131120", "", "1984", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "14.66", "14.66", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 830, "brand_name": "Worcester", "model_name": "240bf", "model_qualifier": "", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 39.2, "output_kw_max": 24.0, "final_year_of_manufacture": 1997, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000830", "000035", "0", "2010/Sep/13 17:03", "Worcester Heat Systems", "Worcester", "240bf", "", "4731110", "", "1997", "1", "2", "1", "2", "0", "", "", "1", "2", "1", "24", "24", "", "", "66.0", "56.0", "", "39.2", "", "3", "", "", "0", "2", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 831, "brand_name": "Worcester", "model_name": "240of", "model_qualifier": "", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 39.2, "output_kw_max": 24.0, "final_year_of_manufacture": 1997, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000831", "000035", "0", "2010/Sep/13 17:03", "Worcester Heat Systems", "Worcester", "240of", "", "4731109", "", "1997", "1", "2", "1", "2", "0", "", "", "1", "1", "1", "24", "24", "", "", "66.0", "56.0", "", "39.2", "", "3", "", "", "0", "2", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 832, "brand_name": "Worcester", "model_name": "240rsf", "model_qualifier": "", "winter_efficiency_pct": 71.0, "summer_efficiency_pct": 61.0, "comparative_hot_water_efficiency_pct": 42.8, "output_kw_max": 16.1, "final_year_of_manufacture": 1997, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000832", "000035", "0", "2010/Sep/13 17:03", "Worcester Heat Systems", "Worcester", "240rsf", "", "4731112", "", "1997", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "16.1", "16.1", "", "", "71.0", "61.0", "", "42.8", "", "3", "", "", "0", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 833, "brand_name": "Worcester", "model_name": "280rsf", "model_qualifier": "", "winter_efficiency_pct": 71.0, "summer_efficiency_pct": 61.0, "comparative_hot_water_efficiency_pct": 42.8, "output_kw_max": 24.0, "final_year_of_manufacture": 1997, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000833", "000035", "0", "2010/Sep/13 17:03", "Worcester Heat Systems", "Worcester", "280rsf", "", "4731111", "", "1997", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "24", "24", "", "", "71.0", "61.0", "", "42.8", "", "3", "", "", "0", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 837, "brand_name": "Worcester", "model_name": "9.24electronicrsf", "model_qualifier": "", "winter_efficiency_pct": 71.0, "summer_efficiency_pct": 61.0, "comparative_hot_water_efficiency_pct": 42.8, "output_kw_max": 24.0, "final_year_of_manufacture": 1992, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000837", "000035", "0", "2010/Sep/13 17:03", "Worcester Heat Systems", "Worcester", "9.24electronicrsf", "", "4731106", "", "1992", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "24", "24", "", "", "71.0", "61.0", "", "42.8", "", "3", "", "", "0", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 838, "brand_name": "Worcester", "model_name": "9.24electronicrsfe", "model_qualifier": "", "winter_efficiency_pct": 71.0, "summer_efficiency_pct": 61.0, "comparative_hot_water_efficiency_pct": 42.8, "output_kw_max": 24.0, "final_year_of_manufacture": 1992, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000838", "000035", "0", "2010/Sep/13 17:03", "Worcester Heat Systems", "Worcester", "9.24electronicrsfe", "", "4731107", "", "1992", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "24", "24", "", "", "71.0", "61.0", "", "42.8", "", "3", "", "", "0", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 843, "brand_name": "Worcester", "model_name": "240", "model_qualifier": "CF", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 39.2, "output_kw_max": 24.0, "final_year_of_manufacture": 1997, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000843", "000035", "0", "2010/Sep/13 17:03", "Worcester Heat Systems", "Worcester", "240", "CF", "47 311 09", "", "1997", "1", "2", "1", "2", "0", "", "", "1", "1", "1", "24", "24", "", "", "66.0", "56.0", "", "39.2", "", "3", "", "", "0", "0", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 847, "brand_name": "Worcester", "model_name": "Firefly HD II", "model_qualifier": "50", "winter_efficiency_pct": 65.0, "summer_efficiency_pct": 53.0, "comparative_hot_water_efficiency_pct": 38.9, "output_kw_max": 14.7, "final_year_of_manufacture": 1985, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000847", "000035", "0", "2010/Sep/13 17:03", "Worcester Heat Systems", "Worcester", "Firefly HD II", "50", "", "", "1985", "4", "1", "1", "1", "0", "", "", "1", "1", "1", "14.7", "14.7", "", "", "65.0", "53.0", "", "38.9", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 848, "brand_name": "Worcester", "model_name": "Firefly HD II", "model_qualifier": "50 D type", "winter_efficiency_pct": 65.0, "summer_efficiency_pct": 53.0, "comparative_hot_water_efficiency_pct": 38.9, "output_kw_max": 14.6, "final_year_of_manufacture": 1985, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000848", "000035", "0", "2010/Sep/13 17:03", "Worcester Heat Systems", "Worcester", "Firefly HD II", "50 D type", "", "", "1985", "4", "1", "1", "1", "0", "", "", "1", "1", "1", "14.6", "14.6", "", "", "65.0", "53.0", "", "38.9", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 850, "brand_name": "Worcester", "model_name": "Firefly HD II", "model_qualifier": "60 D type", "winter_efficiency_pct": 65.0, "summer_efficiency_pct": 53.0, "comparative_hot_water_efficiency_pct": 38.9, "output_kw_max": 17.6, "final_year_of_manufacture": 1985, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000850", "000035", "0", "2010/Sep/13 17:03", "Worcester Heat Systems", "Worcester", "Firefly HD II", "60 D type", "", "", "1985", "4", "1", "1", "1", "0", "", "", "1", "1", "1", "17.6", "17.6", "", "", "65.0", "53.0", "", "38.9", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 851, "brand_name": "Worcester", "model_name": "Firefly HD II", "model_qualifier": "70", "winter_efficiency_pct": 65.0, "summer_efficiency_pct": 53.0, "comparative_hot_water_efficiency_pct": 38.9, "output_kw_max": 20.5, "final_year_of_manufacture": 1985, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000851", "000035", "0", "2010/Sep/13 17:03", "Worcester Heat Systems", "Worcester", "Firefly HD II", "70", "", "", "1985", "4", "1", "1", "1", "0", "", "", "1", "1", "1", "20.5", "20.5", "", "", "65.0", "53.0", "", "38.9", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 852, "brand_name": "Worcester", "model_name": "Firefly HD II", "model_qualifier": "80", "winter_efficiency_pct": 65.0, "summer_efficiency_pct": 53.0, "comparative_hot_water_efficiency_pct": 38.9, "output_kw_max": 23.4, "final_year_of_manufacture": 1985, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000852", "000035", "0", "2010/Sep/13 17:03", "Worcester Heat Systems", "Worcester", "Firefly HD II", "80", "", "", "1985", "4", "1", "1", "1", "0", "", "", "1", "1", "1", "23.4", "23.4", "", "", "65.0", "53.0", "", "38.9", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 853, "brand_name": "Worcester", "model_name": "Firefly HD II", "model_qualifier": "100", "winter_efficiency_pct": 65.0, "summer_efficiency_pct": 53.0, "comparative_hot_water_efficiency_pct": 38.9, "output_kw_max": 29.3, "final_year_of_manufacture": 1985, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000853", "000035", "0", "2010/Sep/13 17:03", "Worcester Heat Systems", "Worcester", "Firefly HD II", "100", "", "", "1985", "4", "1", "1", "1", "0", "", "", "1", "1", "1", "29.3", "29.3", "", "", "65.0", "53.0", "", "38.9", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 855, "brand_name": "Worcester", "model_name": "Firefly", "model_qualifier": "PJ90-120", "winter_efficiency_pct": 65.0, "summer_efficiency_pct": 53.0, "comparative_hot_water_efficiency_pct": 38.9, "output_kw_max": 35.2, "final_year_of_manufacture": 1985, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000855", "000035", "0", "2010/Sep/13 17:03", "Worcester Heat Systems", "Worcester", "Firefly", "PJ90-120", "", "", "1985", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "26.4", "35.2", "", "", "65.0", "53.0", "", "38.9", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 856, "brand_name": "Worcester", "model_name": "Firefly HD II", "model_qualifier": "40", "winter_efficiency_pct": 65.0, "summer_efficiency_pct": 53.0, "comparative_hot_water_efficiency_pct": 38.9, "output_kw_max": 12.3, "final_year_of_manufacture": 1985, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000856", "000035", "0", "2010/Sep/13 17:03", "Worcester Heat Systems", "Worcester", "Firefly HD II", "40", "", "", "1985", "4", "1", "1", "1", "0", "", "", "1", "1", "1", "12.3", "12.3", "", "", "65.0", "53.0", "", "38.9", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 857, "brand_name": "Worcester", "model_name": "Firefly HD II", "model_qualifier": "40 D type", "winter_efficiency_pct": 65.0, "summer_efficiency_pct": 53.0, "comparative_hot_water_efficiency_pct": 38.9, "output_kw_max": 11.7, "final_year_of_manufacture": 1985, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000857", "000035", "0", "2010/Sep/13 17:03", "Worcester Heat Systems", "Worcester", "Firefly HD II", "40 D type", "", "", "1985", "4", "1", "1", "1", "0", "", "", "1", "1", "1", "11.7", "11.7", "", "", "65.0", "53.0", "", "38.9", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 858, "brand_name": "Worcester", "model_name": "Heatslave", "model_qualifier": "12/14RS", "winter_efficiency_pct": 71.0, "summer_efficiency_pct": 62.0, "comparative_hot_water_efficiency_pct": 43.2, "output_kw_max": 14.0, "final_year_of_manufacture": 1996, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000858", "000035", "0", "2010/Sep/13 17:03", "Worcester Heat Systems", "Worcester", "Heatslave", "12/14RS", "HHSC14OSO.AIR", "", "1996", "4", "1", "1", "2", "0", "", "", "1", "2", "2", "12", "14", "", "", "71.0", "62.0", "", "43.2", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 860, "brand_name": "Worcester", "model_name": "Heatslave", "model_qualifier": "20/25RS", "winter_efficiency_pct": 71.0, "summer_efficiency_pct": 62.0, "comparative_hot_water_efficiency_pct": 43.2, "output_kw_max": 25.0, "final_year_of_manufacture": 1996, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000860", "000035", "0", "2010/Sep/13 17:03", "Worcester Heat Systems", "Worcester", "Heatslave", "20/25RS", "HHSC25OSO.AIV", "", "1996", "4", "1", "1", "2", "0", "", "", "1", "2", "2", "20", "25", "", "", "71.0", "62.0", "", "43.2", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 890, "brand_name": "Aquaflame", "model_name": "Gem", "model_qualifier": "50 B", "winter_efficiency_pct": 70.0, "summer_efficiency_pct": 58.0, "comparative_hot_water_efficiency_pct": 42.6, "output_kw_max": 14.7, "final_year_of_manufacture": 1997, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000890", "000039", "0", "2010/Sep/13 17:03", "Aquaflame", "Aquaflame", "Gem", "50 B", "", "", "1997", "4", "0", "0", "1", "0", "", "", "1", "2", "1", "14.7", "14.7", "", "", "70.0", "58.0", "", "42.6", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 891, "brand_name": "Aquaflame", "model_name": "Gem", "model_qualifier": "50 F", "winter_efficiency_pct": 70.0, "summer_efficiency_pct": 58.0, "comparative_hot_water_efficiency_pct": 42.6, "output_kw_max": 14.7, "final_year_of_manufacture": 1997, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000891", "000039", "0", "2010/Sep/13 17:03", "Aquaflame", "Aquaflame", "Gem", "50 F", "", "", "1997", "4", "0", "0", "1", "0", "", "", "1", "2", "2", "14.7", "14.7", "", "", "70.0", "58.0", "", "42.6", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 892, "brand_name": "Aquaflame", "model_name": "Gem", "model_qualifier": "70 B", "winter_efficiency_pct": 70.0, "summer_efficiency_pct": 58.0, "comparative_hot_water_efficiency_pct": 42.6, "output_kw_max": 20.5, "final_year_of_manufacture": 1997, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000892", "000039", "0", "2010/Sep/13 17:03", "Aquaflame", "Aquaflame", "Gem", "70 B", "", "", "1997", "4", "0", "0", "1", "0", "", "", "1", "2", "1", "20.5", "20.5", "", "", "70.0", "58.0", "", "42.6", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 893, "brand_name": "Aquaflame", "model_name": "Gem", "model_qualifier": "70 F", "winter_efficiency_pct": 70.0, "summer_efficiency_pct": 58.0, "comparative_hot_water_efficiency_pct": 42.6, "output_kw_max": 20.5, "final_year_of_manufacture": 1997, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000893", "000039", "0", "2010/Sep/13 17:03", "Aquaflame", "Aquaflame", "Gem", "70 F", "", "", "1997", "4", "0", "0", "1", "0", "", "", "1", "2", "2", "20.5", "20.5", "", "", "70.0", "58.0", "", "42.6", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 894, "brand_name": "Aquaflame", "model_name": "Gem", "model_qualifier": "90 B", "winter_efficiency_pct": 70.0, "summer_efficiency_pct": 58.0, "comparative_hot_water_efficiency_pct": 42.6, "output_kw_max": 26.4, "final_year_of_manufacture": 1997, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000894", "000039", "0", "2010/Sep/13 17:03", "Aquaflame", "Aquaflame", "Gem", "90 B", "", "", "1997", "4", "0", "0", "1", "0", "", "", "1", "2", "1", "26.4", "26.4", "", "", "70.0", "58.0", "", "42.6", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 895, "brand_name": "Aquaflame", "model_name": "Gem", "model_qualifier": "90 F", "winter_efficiency_pct": 70.0, "summer_efficiency_pct": 58.0, "comparative_hot_water_efficiency_pct": 42.6, "output_kw_max": 26.4, "final_year_of_manufacture": 1997, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000895", "000039", "0", "2010/Sep/13 17:03", "Aquaflame", "Aquaflame", "Gem", "90 F", "", "", "1997", "4", "0", "0", "1", "0", "", "", "1", "2", "2", "26.4", "26.4", "", "", "70.0", "58.0", "", "42.6", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 896, "brand_name": "Aquaflame", "model_name": "Quartz", "model_qualifier": "110 B", "winter_efficiency_pct": 70.0, "summer_efficiency_pct": 58.0, "comparative_hot_water_efficiency_pct": 42.6, "output_kw_max": 32.2, "final_year_of_manufacture": 1997, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000896", "000039", "0", "2010/Sep/13 17:03", "Aquaflame", "Aquaflame", "Quartz", "110 B", "", "", "1997", "4", "0", "0", "1", "0", "", "", "1", "2", "1", "32.2", "32.2", "", "", "70.0", "58.0", "", "42.6", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 897, "brand_name": "Aquaflame", "model_name": "Quartz", "model_qualifier": "110 F", "winter_efficiency_pct": 70.0, "summer_efficiency_pct": 58.0, "comparative_hot_water_efficiency_pct": 42.6, "output_kw_max": 32.2, "final_year_of_manufacture": 1997, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000897", "000039", "0", "2010/Sep/13 17:03", "Aquaflame", "Aquaflame", "Quartz", "110 F", "", "", "1997", "4", "0", "0", "1", "0", "", "", "1", "2", "2", "32.2", "32.2", "", "", "70.0", "58.0", "", "42.6", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 898, "brand_name": "Aquaflame", "model_name": "Quartz", "model_qualifier": "135 B", "winter_efficiency_pct": 70.0, "summer_efficiency_pct": 58.0, "comparative_hot_water_efficiency_pct": 42.6, "output_kw_max": 39.6, "final_year_of_manufacture": 1997, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000898", "000039", "0", "2010/Sep/13 17:03", "Aquaflame", "Aquaflame", "Quartz", "135 B", "", "", "1997", "4", "0", "0", "1", "0", "", "", "1", "2", "1", "39.6", "39.6", "", "", "70.0", "58.0", "", "42.6", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 899, "brand_name": "Aquaflame", "model_name": "Quartz", "model_qualifier": "135 F", "winter_efficiency_pct": 70.0, "summer_efficiency_pct": 58.0, "comparative_hot_water_efficiency_pct": 42.6, "output_kw_max": 39.6, "final_year_of_manufacture": 1997, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000899", "000039", "0", "2010/Sep/13 17:03", "Aquaflame", "Aquaflame", "Quartz", "135 F", "", "", "1997", "4", "0", "0", "1", "0", "", "", "1", "2", "2", "39.6", "39.6", "", "", "70.0", "58.0", "", "42.6", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 900, "brand_name": "Aquaflame", "model_name": "Quartz", "model_qualifier": "160 B", "winter_efficiency_pct": 70.0, "summer_efficiency_pct": 58.0, "comparative_hot_water_efficiency_pct": 42.6, "output_kw_max": 46.9, "final_year_of_manufacture": 1997, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000900", "000039", "0", "2010/Sep/13 17:03", "Aquaflame", "Aquaflame", "Quartz", "160 B", "", "", "1997", "4", "0", "0", "1", "0", "", "", "1", "2", "1", "46.9", "46.9", "", "", "70.0", "58.0", "", "42.6", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 901, "brand_name": "Aquaflame", "model_name": "Quartz", "model_qualifier": "160 F", "winter_efficiency_pct": 70.0, "summer_efficiency_pct": 58.0, "comparative_hot_water_efficiency_pct": 42.6, "output_kw_max": 46.9, "final_year_of_manufacture": 1997, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000901", "000039", "0", "2010/Sep/13 17:03", "Aquaflame", "Aquaflame", "Quartz", "160 F", "", "", "1997", "4", "0", "0", "1", "0", "", "", "1", "2", "2", "46.9", "46.9", "", "", "70.0", "58.0", "", "42.6", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 902, "brand_name": "Aquaflame", "model_name": "Gem", "model_qualifier": "50", "winter_efficiency_pct": 70.0, "summer_efficiency_pct": 58.0, "comparative_hot_water_efficiency_pct": 42.6, "output_kw_max": null, "final_year_of_manufacture": 1997, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000902", "000039", "0", "2010/Sep/13 17:03", "Aquaflame", "Aquaflame", "Gem", "50", "", "", "1997", "4", "0", "0", "1", "0", "", "", "1", "2", "2", "", "", "", "", "70.0", "58.0", "", "42.6", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 903, "brand_name": "Aquaflame", "model_name": "Gem", "model_qualifier": "70", "winter_efficiency_pct": 70.0, "summer_efficiency_pct": 58.0, "comparative_hot_water_efficiency_pct": 42.6, "output_kw_max": null, "final_year_of_manufacture": 1997, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000903", "000039", "0", "2010/Sep/13 17:03", "Aquaflame", "Aquaflame", "Gem", "70", "", "", "1997", "4", "0", "0", "1", "0", "", "", "1", "2", "2", "", "", "", "", "70.0", "58.0", "", "42.6", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 904, "brand_name": "Aquaflame", "model_name": "Gem", "model_qualifier": "90", "winter_efficiency_pct": 70.0, "summer_efficiency_pct": 58.0, "comparative_hot_water_efficiency_pct": 42.6, "output_kw_max": null, "final_year_of_manufacture": 1997, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000904", "000039", "0", "2010/Sep/13 17:03", "Aquaflame", "Aquaflame", "Gem", "90", "", "", "1997", "4", "0", "0", "1", "0", "", "", "1", "2", "2", "", "", "", "", "70.0", "58.0", "", "42.6", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 905, "brand_name": "Aquaflame", "model_name": "Quartz", "model_qualifier": "110", "winter_efficiency_pct": 70.0, "summer_efficiency_pct": 58.0, "comparative_hot_water_efficiency_pct": 42.6, "output_kw_max": null, "final_year_of_manufacture": 1997, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000905", "000039", "0", "2010/Sep/13 17:03", "Aquaflame", "Aquaflame", "Quartz", "110", "", "", "1997", "4", "0", "0", "1", "0", "", "", "1", "2", "2", "", "", "", "", "70.0", "58.0", "", "42.6", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 906, "brand_name": "Aquaflame", "model_name": "Quartz", "model_qualifier": "135", "winter_efficiency_pct": 70.0, "summer_efficiency_pct": 58.0, "comparative_hot_water_efficiency_pct": 42.6, "output_kw_max": null, "final_year_of_manufacture": 1997, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000906", "000039", "0", "2010/Sep/13 17:03", "Aquaflame", "Aquaflame", "Quartz", "135", "", "", "1997", "4", "0", "0", "1", "0", "", "", "1", "2", "2", "", "", "", "", "70.0", "58.0", "", "42.6", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 907, "brand_name": "Aquaflame", "model_name": "Quartz", "model_qualifier": "150", "winter_efficiency_pct": 70.0, "summer_efficiency_pct": 58.0, "comparative_hot_water_efficiency_pct": 42.6, "output_kw_max": null, "final_year_of_manufacture": 1997, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000907", "000039", "0", "2010/Sep/13 17:03", "Aquaflame", "Aquaflame", "Quartz", "150", "", "", "1997", "4", "0", "0", "1", "0", "", "", "1", "2", "2", "", "", "", "", "70.0", "58.0", "", "42.6", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 918, "brand_name": "Boulter", "model_name": "Camray Compact", "model_qualifier": "50/70 B", "winter_efficiency_pct": 70.0, "summer_efficiency_pct": 58.0, "comparative_hot_water_efficiency_pct": 42.6, "output_kw_max": 15.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000918", "000041", "0", "2010/Sep/13 17:03", "Boulter Boilers", "Boulter", "Camray Compact", "50/70 B", "", "", "obsolete", "4", "0", "0", "1", "0", "", "", "1", "2", "1", "12", "15", "", "", "70.0", "58.0", "", "42.6", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 919, "brand_name": "Boulter", "model_name": "Camray Compact", "model_qualifier": "50/70 F", "winter_efficiency_pct": 70.0, "summer_efficiency_pct": 58.0, "comparative_hot_water_efficiency_pct": 42.6, "output_kw_max": 15.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000919", "000041", "0", "2010/Sep/13 17:03", "Boulter Boilers", "Boulter", "Camray Compact", "50/70 F", "", "", "obsolete", "4", "0", "0", "1", "0", "", "", "1", "2", "2", "12", "15", "", "", "70.0", "58.0", "", "42.6", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 920, "brand_name": "Boulter", "model_name": "Camray", "model_qualifier": "15/21 Internal", "winter_efficiency_pct": 70.0, "summer_efficiency_pct": 58.0, "comparative_hot_water_efficiency_pct": 42.6, "output_kw_max": 21.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000920", "000041", "0", "2010/Sep/13 17:03", "Boulter Boilers", "Boulter", "Camray", "15/21 Internal", "", "", "obsolete", "4", "0", "0", "1", "0", "", "", "1", "2", "2", "15", "21", "", "", "70.0", "58.0", "", "42.6", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 922, "brand_name": "Boulter", "model_name": "Camray", "model_qualifier": "15/21 External", "winter_efficiency_pct": 70.0, "summer_efficiency_pct": 58.0, "comparative_hot_water_efficiency_pct": 42.6, "output_kw_max": 21.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000922", "000041", "0", "2010/Sep/13 17:03", "Boulter Boilers", "Boulter", "Camray", "15/21 External", "", "", "obsolete", "4", "0", "0", "1", "0", "", "", "1", "2", "2", "15", "21", "", "", "70.0", "58.0", "", "42.6", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 923, "brand_name": "Boulter", "model_name": "Camray 3", "model_qualifier": "40/50", "winter_efficiency_pct": 70.0, "summer_efficiency_pct": 58.0, "comparative_hot_water_efficiency_pct": 42.6, "output_kw_max": 15.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000923", "000041", "0", "2010/Sep/13 17:03", "Boulter Boilers", "Boulter", "Camray 3", "40/50", "", "", "obsolete", "4", "0", "0", "1", "0", "", "", "1", "2", "2", "12", "15", "", "", "70.0", "58.0", "", "42.6", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 925, "brand_name": "Boulter", "model_name": "Camray 3", "model_qualifier": "50/70", "winter_efficiency_pct": 70.0, "summer_efficiency_pct": 58.0, "comparative_hot_water_efficiency_pct": 42.6, "output_kw_max": 20.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000925", "000041", "0", "2010/Sep/13 17:03", "Boulter Boilers", "Boulter", "Camray 3", "50/70", "", "", "obsolete", "4", "0", "0", "1", "0", "", "", "1", "2", "2", "14.5", "20", "", "", "70.0", "58.0", "", "42.6", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 929, "brand_name": "Boulter", "model_name": "Camray 3", "model_qualifier": "90/130 F", "winter_efficiency_pct": 70.0, "summer_efficiency_pct": 58.0, "comparative_hot_water_efficiency_pct": 42.6, "output_kw_max": 38.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000929", "000041", "0", "2010/Sep/13 17:03", "Boulter Boilers", "Boulter", "Camray 3", "90/130 F", "", "", "obsolete", "4", "0", "0", "1", "0", "", "", "1", "2", "2", "26", "38", "", "", "70.0", "58.0", "", "42.6", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 930, "brand_name": "Boulter", "model_name": "Camray 3", "model_qualifier": "90/130 B", "winter_efficiency_pct": 70.0, "summer_efficiency_pct": 58.0, "comparative_hot_water_efficiency_pct": 42.6, "output_kw_max": 38.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000930", "000041", "0", "2010/Sep/13 17:03", "Boulter Boilers", "Boulter", "Camray 3", "90/130 B", "", "", "obsolete", "4", "0", "0", "1", "0", "", "", "1", "2", "1", "26", "38", "", "", "70.0", "58.0", "", "42.6", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 931, "brand_name": "Boulter", "model_name": "Camray 3", "model_qualifier": "135/175 F", "winter_efficiency_pct": 70.0, "summer_efficiency_pct": 58.0, "comparative_hot_water_efficiency_pct": 42.6, "output_kw_max": 51.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000931", "000041", "0", "2010/Sep/13 17:03", "Boulter Boilers", "Boulter", "Camray 3", "135/175 F", "", "", "obsolete", "4", "0", "0", "1", "0", "", "", "1", "2", "2", "40", "51", "", "", "70.0", "58.0", "", "42.6", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 932, "brand_name": "Boulter", "model_name": "Camray 3", "model_qualifier": "135/175 B", "winter_efficiency_pct": 70.0, "summer_efficiency_pct": 58.0, "comparative_hot_water_efficiency_pct": 42.6, "output_kw_max": 51.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000932", "000041", "0", "2010/Sep/13 17:03", "Boulter Boilers", "Boulter", "Camray 3", "135/175 B", "", "", "obsolete", "4", "0", "0", "1", "0", "", "", "1", "2", "1", "40", "51", "", "", "70.0", "58.0", "", "42.6", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 933, "brand_name": "Boulter", "model_name": "Camray Combi", "model_qualifier": "90/130 F", "winter_efficiency_pct": 71.0, "summer_efficiency_pct": 62.0, "comparative_hot_water_efficiency_pct": 43.2, "output_kw_max": 38.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000933", "000041", "0", "2010/Sep/13 17:03", "Boulter Boilers", "Boulter", "Camray Combi", "90/130 F", "", "", "obsolete", "4", "0", "0", "2", "0", "", "", "1", "2", "2", "26", "38", "", "", "71.0", "62.0", "", "43.2", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 934, "brand_name": "Boulter", "model_name": "Camray Combi", "model_qualifier": "90/130 B", "winter_efficiency_pct": 71.0, "summer_efficiency_pct": 62.0, "comparative_hot_water_efficiency_pct": 43.2, "output_kw_max": 38.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000934", "000041", "0", "2010/Sep/13 17:03", "Boulter Boilers", "Boulter", "Camray Combi", "90/130 B", "", "", "obsolete", "4", "0", "0", "2", "0", "", "", "1", "2", "1", "26", "38", "", "", "71.0", "62.0", "", "43.2", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 938, "brand_name": "Boulter", "model_name": "Camray Quartet", "model_qualifier": "40/60 B", "winter_efficiency_pct": 70.0, "summer_efficiency_pct": 58.0, "comparative_hot_water_efficiency_pct": 42.6, "output_kw_max": 17.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000938", "000041", "0", "2010/Sep/13 17:03", "Boulter Boilers", "Boulter", "Camray Quartet", "40/60 B", "", "", "obsolete", "4", "0", "0", "1", "0", "", "", "1", "2", "1", "12", "17", "", "", "70.0", "58.0", "", "42.6", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 939, "brand_name": "Boulter", "model_name": "Camray Quartet", "model_qualifier": "40/60 F", "winter_efficiency_pct": 70.0, "summer_efficiency_pct": 58.0, "comparative_hot_water_efficiency_pct": 42.6, "output_kw_max": 17.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000939", "000041", "0", "2010/Sep/13 17:03", "Boulter Boilers", "Boulter", "Camray Quartet", "40/60 F", "", "", "obsolete", "4", "0", "0", "1", "0", "", "", "1", "2", "2", "12", "17", "", "", "70.0", "58.0", "", "42.6", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 940, "brand_name": "Boulter", "model_name": "Camray Quartet", "model_qualifier": "60/80 F", "winter_efficiency_pct": 70.0, "summer_efficiency_pct": 58.0, "comparative_hot_water_efficiency_pct": 42.6, "output_kw_max": 23.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000940", "000041", "0", "2010/Sep/13 17:03", "Boulter Boilers", "Boulter", "Camray Quartet", "60/80 F", "", "", "obsolete", "4", "0", "0", "1", "0", "", "", "1", "2", "2", "17", "23", "", "", "70.0", "58.0", "", "42.6", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 941, "brand_name": "Boulter", "model_name": "Camray Quartet", "model_qualifier": "60/80 B", "winter_efficiency_pct": 70.0, "summer_efficiency_pct": 58.0, "comparative_hot_water_efficiency_pct": 42.6, "output_kw_max": 23.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000941", "000041", "0", "2010/Sep/13 17:03", "Boulter Boilers", "Boulter", "Camray Quartet", "60/80 B", "", "", "obsolete", "4", "0", "0", "1", "0", "", "", "1", "2", "1", "17", "23", "", "", "70.0", "58.0", "", "42.6", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 942, "brand_name": "Boulter", "model_name": "Camray Quartet", "model_qualifier": "90/110 F", "winter_efficiency_pct": 70.0, "summer_efficiency_pct": 58.0, "comparative_hot_water_efficiency_pct": 42.6, "output_kw_max": 32.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000942", "000041", "0", "2010/Sep/13 17:03", "Boulter Boilers", "Boulter", "Camray Quartet", "90/110 F", "", "", "obsolete", "4", "0", "0", "1", "0", "", "", "1", "2", "2", "26", "32", "", "", "70.0", "58.0", "", "42.6", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 943, "brand_name": "Boulter", "model_name": "Camray Quartet", "model_qualifier": "90/110 B", "winter_efficiency_pct": 70.0, "summer_efficiency_pct": 58.0, "comparative_hot_water_efficiency_pct": 42.6, "output_kw_max": 32.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000943", "000041", "0", "2010/Sep/13 17:03", "Boulter Boilers", "Boulter", "Camray Quartet", "90/110 B", "", "", "obsolete", "4", "0", "0", "1", "0", "", "", "1", "2", "1", "26", "32", "", "", "70.0", "58.0", "", "42.6", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 944, "brand_name": "Boulter", "model_name": "Camray Quartet", "model_qualifier": "110/150 F", "winter_efficiency_pct": 70.0, "summer_efficiency_pct": 58.0, "comparative_hot_water_efficiency_pct": 42.6, "output_kw_max": 44.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000944", "000041", "0", "2010/Sep/13 17:03", "Boulter Boilers", "Boulter", "Camray Quartet", "110/150 F", "", "", "obsolete", "4", "0", "0", "1", "0", "", "", "1", "2", "2", "32", "44", "", "", "70.0", "58.0", "", "42.6", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 945, "brand_name": "Boulter", "model_name": "Camray Quartet", "model_qualifier": "110/150 B", "winter_efficiency_pct": 70.0, "summer_efficiency_pct": 58.0, "comparative_hot_water_efficiency_pct": 42.6, "output_kw_max": 44.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000945", "000041", "0", "2010/Sep/13 17:03", "Boulter Boilers", "Boulter", "Camray Quartet", "110/150 B", "", "", "obsolete", "4", "0", "0", "1", "0", "", "", "1", "2", "1", "32", "44", "", "", "70.0", "58.0", "", "42.6", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 946, "brand_name": "Boulter", "model_name": "Camray Utility", "model_qualifier": "40/60 B", "winter_efficiency_pct": 70.0, "summer_efficiency_pct": 58.0, "comparative_hot_water_efficiency_pct": 42.6, "output_kw_max": 17.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000946", "000041", "0", "2010/Sep/13 17:03", "Boulter Boilers", "Boulter", "Camray Utility", "40/60 B", "", "", "obsolete", "4", "0", "0", "1", "0", "", "", "1", "2", "1", "12", "17", "", "", "70.0", "58.0", "", "42.6", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 947, "brand_name": "Boulter", "model_name": "Camray Utility", "model_qualifier": "40/60 F", "winter_efficiency_pct": 70.0, "summer_efficiency_pct": 58.0, "comparative_hot_water_efficiency_pct": 42.6, "output_kw_max": 17.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000947", "000041", "0", "2010/Sep/13 17:03", "Boulter Boilers", "Boulter", "Camray Utility", "40/60 F", "", "", "obsolete", "4", "0", "0", "1", "0", "", "", "1", "2", "2", "12", "17", "", "", "70.0", "58.0", "", "42.6", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 948, "brand_name": "Boulter", "model_name": "Camray Utility", "model_qualifier": "60/80 F", "winter_efficiency_pct": 70.0, "summer_efficiency_pct": 58.0, "comparative_hot_water_efficiency_pct": 42.6, "output_kw_max": 23.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000948", "000041", "0", "2010/Sep/13 17:03", "Boulter Boilers", "Boulter", "Camray Utility", "60/80 F", "", "", "obsolete", "4", "0", "0", "1", "0", "", "", "1", "2", "2", "17", "23", "", "", "70.0", "58.0", "", "42.6", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 949, "brand_name": "Boulter", "model_name": "Camray Utility", "model_qualifier": "60/80 B", "winter_efficiency_pct": 70.0, "summer_efficiency_pct": 58.0, "comparative_hot_water_efficiency_pct": 42.6, "output_kw_max": 23.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000949", "000041", "0", "2010/Sep/13 17:03", "Boulter Boilers", "Boulter", "Camray Utility", "60/80 B", "", "", "obsolete", "4", "0", "0", "1", "0", "", "", "1", "2", "1", "17", "23", "", "", "70.0", "58.0", "", "42.6", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 950, "brand_name": "Boulter", "model_name": "Camray Utility", "model_qualifier": "90/110 F", "winter_efficiency_pct": 70.0, "summer_efficiency_pct": 58.0, "comparative_hot_water_efficiency_pct": 42.6, "output_kw_max": 32.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000950", "000041", "0", "2010/Sep/13 17:03", "Boulter Boilers", "Boulter", "Camray Utility", "90/110 F", "", "", "obsolete", "4", "0", "0", "1", "0", "", "", "1", "2", "2", "26", "32", "", "", "70.0", "58.0", "", "42.6", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 951, "brand_name": "Boulter", "model_name": "Camray Utility", "model_qualifier": "90/110 B", "winter_efficiency_pct": 70.0, "summer_efficiency_pct": 58.0, "comparative_hot_water_efficiency_pct": 42.6, "output_kw_max": 32.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000951", "000041", "0", "2010/Sep/13 17:03", "Boulter Boilers", "Boulter", "Camray Utility", "90/110 B", "", "", "obsolete", "4", "0", "0", "1", "0", "", "", "1", "2", "1", "26", "32", "", "", "70.0", "58.0", "", "42.6", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 952, "brand_name": "Boulter", "model_name": "Camray Utility", "model_qualifier": "110/150 F", "winter_efficiency_pct": 70.0, "summer_efficiency_pct": 58.0, "comparative_hot_water_efficiency_pct": 42.6, "output_kw_max": 44.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000952", "000041", "0", "2010/Sep/13 17:03", "Boulter Boilers", "Boulter", "Camray Utility", "110/150 F", "", "", "obsolete", "4", "0", "0", "1", "0", "", "", "1", "2", "2", "32", "44", "", "", "70.0", "58.0", "", "42.6", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 953, "brand_name": "Boulter", "model_name": "Camray Utility", "model_qualifier": "110/150 B", "winter_efficiency_pct": 70.0, "summer_efficiency_pct": 58.0, "comparative_hot_water_efficiency_pct": 42.6, "output_kw_max": 44.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000953", "000041", "0", "2010/Sep/13 17:03", "Boulter Boilers", "Boulter", "Camray Utility", "110/150 B", "", "", "obsolete", "4", "0", "0", "1", "0", "", "", "1", "2", "1", "32", "44", "", "", "70.0", "58.0", "", "42.6", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 954, "brand_name": "Boulter", "model_name": "Economy", "model_qualifier": "50/70", "winter_efficiency_pct": 70.0, "summer_efficiency_pct": 58.0, "comparative_hot_water_efficiency_pct": 42.6, "output_kw_max": 21.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000954", "000041", "0", "2010/Sep/13 17:03", "Boulter Boilers", "Boulter", "Economy", "50/70", "", "", "obsolete", "4", "0", "0", "1", "0", "", "", "1", "2", "2", "15", "21", "", "", "70.0", "58.0", "", "42.6", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 955, "brand_name": "Boulter", "model_name": "Economy", "model_qualifier": "70/90", "winter_efficiency_pct": 70.0, "summer_efficiency_pct": 58.0, "comparative_hot_water_efficiency_pct": 42.6, "output_kw_max": 26.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000955", "000041", "0", "2010/Sep/13 17:03", "Boulter Boilers", "Boulter", "Economy", "70/90", "", "", "obsolete", "4", "0", "0", "1", "0", "", "", "1", "2", "2", "21", "26", "", "", "70.0", "58.0", "", "42.6", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 958, "brand_name": "Boulter", "model_name": "Economy", "model_qualifier": "90", "winter_efficiency_pct": 71.0, "summer_efficiency_pct": 62.0, "comparative_hot_water_efficiency_pct": 43.2, "output_kw_max": 26.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000958", "000041", "0", "2010/Sep/13 17:03", "Boulter Boilers", "Boulter", "Economy", "90", "", "", "obsolete", "4", "0", "0", "2", "0", "", "", "1", "2", "2", "26", "26", "", "", "71.0", "62.0", "", "43.2", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 959, "brand_name": "Boulter", "model_name": "Economy", "model_qualifier": "130", "winter_efficiency_pct": 71.0, "summer_efficiency_pct": 62.0, "comparative_hot_water_efficiency_pct": 43.2, "output_kw_max": 38.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000959", "000041", "0", "2010/Sep/13 17:03", "Boulter Boilers", "Boulter", "Economy", "130", "", "", "obsolete", "4", "0", "0", "2", "0", "", "", "1", "2", "2", "38", "38", "", "", "71.0", "62.0", "", "43.2", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 970, "brand_name": "Charles Portway & Son", "model_name": "Portway Inset Trio", "model_qualifier": "", "winter_efficiency_pct": 65.0, "summer_efficiency_pct": 53.0, "comparative_hot_water_efficiency_pct": 38.9, "output_kw_max": 8.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000970", "000140", "0", "2010/Sep/13 17:03", "Charles Portway & Son", "Charles Portway & Son", "Portway Inset Trio", "", "", "", "obsolete", "4", "0", "0", "1", "0", "", "", "1", "1", "1", "8.5", "8.5", "", "", "65.0", "53.0", "", "38.9", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 971, "brand_name": "Charles Portway & Son", "model_name": "Portway Trio MkIV", "model_qualifier": "", "winter_efficiency_pct": 65.0, "summer_efficiency_pct": 53.0, "comparative_hot_water_efficiency_pct": 38.9, "output_kw_max": 8.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000971", "000140", "0", "2010/Sep/13 17:03", "Charles Portway & Son", "Charles Portway & Son", "Portway Trio MkIV", "", "", "", "obsolete", "4", "0", "0", "1", "0", "", "", "1", "1", "1", "8.5", "8.5", "", "", "65.0", "53.0", "", "38.9", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 972, "brand_name": "Charles Portway & Son", "model_name": "Portway Tortoisaire MkIII", "model_qualifier": "", "winter_efficiency_pct": 65.0, "summer_efficiency_pct": 53.0, "comparative_hot_water_efficiency_pct": 38.9, "output_kw_max": 11.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000972", "000140", "0", "2010/Sep/13 17:03", "Charles Portway & Son", "Charles Portway & Son", "Portway Tortoisaire MkIII", "", "", "", "obsolete", "4", "0", "0", "1", "0", "", "", "1", "1", "1", "11.5", "11.5", "", "", "65.0", "53.0", "", "38.9", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 973, "brand_name": "Charles Portway & Son", "model_name": "Portway Visaire", "model_qualifier": "", "winter_efficiency_pct": 65.0, "summer_efficiency_pct": 53.0, "comparative_hot_water_efficiency_pct": 38.9, "output_kw_max": 8.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000973", "000140", "0", "2010/Sep/13 17:03", "Charles Portway & Son", "Charles Portway & Son", "Portway Visaire", "", "", "", "obsolete", "4", "0", "0", "1", "0", "", "", "1", "1", "1", "8.5", "8.5", "", "", "65.0", "53.0", "", "38.9", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 974, "brand_name": "Charles Portway & Son", "model_name": "Portway", "model_qualifier": "40F", "winter_efficiency_pct": 65.0, "summer_efficiency_pct": 53.0, "comparative_hot_water_efficiency_pct": 38.9, "output_kw_max": 11.1, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000974", "000140", "0", "2010/Sep/13 17:03", "Charles Portway & Son", "Charles Portway & Son", "Portway", "40F", "", "", "obsolete", "4", "0", "0", "1", "0", "", "", "1", "1", "1", "11.1", "11.1", "", "", "65.0", "53.0", "", "38.9", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 986, "brand_name": "Heating World Group", "model_name": "Beta", "model_qualifier": "42339", "winter_efficiency_pct": 70.0, "summer_efficiency_pct": 58.0, "comparative_hot_water_efficiency_pct": 42.6, "output_kw_max": 15.0, "final_year_of_manufacture": 1992, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000986", "000050", "0", "2010/Sep/13 17:03", "Heating World Group", "Heating World Group", "Beta", "42339", "", "", "1992", "4", "0", "0", "1", "0", "", "", "1", "2", "2", "12", "15", "", "", "70.0", "58.0", "", "42.6", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 988, "brand_name": "Heating World Group", "model_name": "Beta", "model_qualifier": "15/19", "winter_efficiency_pct": 70.0, "summer_efficiency_pct": 58.0, "comparative_hot_water_efficiency_pct": 42.6, "output_kw_max": 19.0, "final_year_of_manufacture": 1991, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000988", "000050", "0", "2010/Sep/13 17:03", "Heating World Group", "Heating World Group", "Beta", "15/19", "", "", "1991", "4", "0", "0", "1", "0", "", "", "1", "2", "2", "15", "19", "", "", "70.0", "58.0", "", "42.6", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 989, "brand_name": "Heating World Group", "model_name": "Beta", "model_qualifier": "15/17 WM", "winter_efficiency_pct": 70.0, "summer_efficiency_pct": 58.0, "comparative_hot_water_efficiency_pct": 42.6, "output_kw_max": 17.0, "final_year_of_manufacture": 1991, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["000989", "000050", "0", "2010/Sep/13 17:03", "Heating World Group", "Heating World Group", "Beta", "15/17 WM", "", "", "1991", "4", "0", "0", "1", "0", "", "", "1", "2", "2", "15", "17", "", "", "70.0", "58.0", "", "42.6", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1044, "brand_name": "Husqvarna", "model_name": "Husqvarna", "model_qualifier": "8AW/D", "winter_efficiency_pct": 65.0, "summer_efficiency_pct": 53.0, "comparative_hot_water_efficiency_pct": 38.9, "output_kw_max": 9.7, "final_year_of_manufacture": 1978, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001044", "000140", "0", "2010/Sep/13 17:03", "Husqvarna", "Husqvarna", "Husqvarna", "8AW/D", "", "", "1978", "4", "0", "0", "1", "0", "", "", "1", "1", "1", "9.7", "9.7", "", "", "65.0", "53.0", "", "38.9", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1064, "brand_name": "Perrymatics", "model_name": "Perrymatic", "model_qualifier": "50", "winter_efficiency_pct": 65.0, "summer_efficiency_pct": 53.0, "comparative_hot_water_efficiency_pct": 38.9, "output_kw_max": 14.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001064", "000040", "0", "2010/Sep/13 17:03", "Perrymatics", "Perrymatics", "Perrymatic", "50", "", "", "obsolete", "4", "0", "0", "1", "0", "", "", "1", "1", "1", "14.6", "14.6", "", "", "65.0", "53.0", "", "38.9", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1066, "brand_name": "Perrymatics", "model_name": "Perrymatic", "model_qualifier": "50/60", "winter_efficiency_pct": 65.0, "summer_efficiency_pct": 53.0, "comparative_hot_water_efficiency_pct": 38.9, "output_kw_max": 17.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001066", "000040", "0", "2010/Sep/13 17:03", "Perrymatics", "Perrymatics", "Perrymatic", "50/60", "", "", "obsolete", "4", "0", "0", "1", "0", "", "", "1", "1", "1", "14.6", "17.6", "", "", "65.0", "53.0", "", "38.9", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1067, "brand_name": "Perrymatics", "model_name": "Perrymatic", "model_qualifier": "80", "winter_efficiency_pct": 65.0, "summer_efficiency_pct": 53.0, "comparative_hot_water_efficiency_pct": 38.9, "output_kw_max": 23.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001067", "000040", "0", "2010/Sep/13 17:03", "Perrymatics", "Perrymatics", "Perrymatic", "80", "", "", "obsolete", "4", "0", "0", "1", "0", "", "", "1", "1", "1", "23.4", "23.4", "", "", "65.0", "53.0", "", "38.9", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1068, "brand_name": "Perrymatics", "model_name": "Perrymatic", "model_qualifier": "95", "winter_efficiency_pct": 65.0, "summer_efficiency_pct": 53.0, "comparative_hot_water_efficiency_pct": 38.9, "output_kw_max": 27.8, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001068", "000040", "0", "2010/Sep/13 17:03", "Perrymatics", "Perrymatics", "Perrymatic", "95", "", "", "obsolete", "4", "0", "0", "1", "0", "", "", "1", "1", "1", "27.8", "27.8", "", "", "65.0", "53.0", "", "38.9", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1071, "brand_name": "Perrymatics", "model_name": "Perrymatic Jetstreme Mk1", "model_qualifier": "", "winter_efficiency_pct": 65.0, "summer_efficiency_pct": 53.0, "comparative_hot_water_efficiency_pct": 38.9, "output_kw_max": 26.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001071", "000040", "0", "2010/Sep/13 17:03", "Perrymatics", "Perrymatics", "Perrymatic Jetstreme Mk1", "", "", "", "obsolete", "4", "0", "0", "1", "0", "", "", "1", "2", "2", "20.5", "26.4", "", "", "65.0", "53.0", "", "38.9", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1072, "brand_name": "Potterton International Heating", "model_name": "35Bf", "model_qualifier": "35bf", "winter_efficiency_pct": 56.0, "summer_efficiency_pct": 46.0, "comparative_hot_water_efficiency_pct": 33.5, "output_kw_max": 9.7, "final_year_of_manufacture": 1976, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001072", "000005", "0", "2010/Sep/13 17:03", "Potterton International Heating", "Potterton International Heating", "35Bf", "35bf", "4178914", "", "1976", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "9.7", "9.7", "", "", "56.0", "46.0", "", "33.5", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1073, "brand_name": "Potterton Myson Heating", "model_name": "35Bf", "model_qualifier": "35bf", "winter_efficiency_pct": 56.0, "summer_efficiency_pct": 46.0, "comparative_hot_water_efficiency_pct": 33.5, "output_kw_max": 9.7, "final_year_of_manufacture": 1978, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001073", "000005", "0", "2010/Sep/13 17:03", "Potterton Myson Heating", "Potterton Myson Heating", "35Bf", "35bf", "4178914", "", "1978", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "9.7", "9.7", "", "", "56.0", "46.0", "", "33.5", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1074, "brand_name": "Potterton Myson Heating", "model_name": "35Cf", "model_qualifier": "35cf", "winter_efficiency_pct": 56.0, "summer_efficiency_pct": 46.0, "comparative_hot_water_efficiency_pct": 33.5, "output_kw_max": 9.7, "final_year_of_manufacture": 1976, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001074", "000005", "0", "2010/Sep/13 17:03", "Potterton Myson Heating", "Potterton Myson Heating", "35Cf", "35cf", "4178926", "", "1976", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "9.7", "9.7", "", "", "56.0", "46.0", "", "33.5", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1075, "brand_name": "Potterton International Heating", "model_name": "35Cf", "model_qualifier": "35cf", "winter_efficiency_pct": 56.0, "summer_efficiency_pct": 46.0, "comparative_hot_water_efficiency_pct": 33.5, "output_kw_max": 9.7, "final_year_of_manufacture": 1976, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001075", "000005", "0", "2010/Sep/13 17:03", "Potterton International Heating", "Potterton International Heating", "35Cf", "35cf", "4178913", "", "1976", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "9.7", "9.7", "", "", "56.0", "46.0", "", "33.5", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1076, "brand_name": "Thorn EMI Heating", "model_name": "Apollo", "model_qualifier": "15/30b", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 8.8, "final_year_of_manufacture": 1990, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001076", "000005", "0", "2010/Sep/13 17:03", "Thorn EMI Heating", "Thorn EMI Heating", "Apollo", "15/30b", "4178953", "", "1990", "1", "2", "1", "1", "0", "", "", "1", "2", "1", "4.4", "8.8", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "1", "20", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1077, "brand_name": "Thorn EMI Heating", "model_name": "Apollo", "model_qualifier": "15/30c", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 8.8, "final_year_of_manufacture": 1990, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001077", "000005", "0", "2010/Sep/13 17:03", "Thorn EMI Heating", "Thorn EMI Heating", "Apollo", "15/30c", "4178955", "", "1990", "1", "2", "1", "1", "0", "", "", "1", "1", "1", "4.4", "8.8", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "1", "20", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1078, "brand_name": "Thorn EMI Heating", "model_name": "Apollo", "model_qualifier": "30/50b", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 14.7, "final_year_of_manufacture": 1990, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001078", "000005", "0", "2010/Sep/13 17:03", "Thorn EMI Heating", "Thorn EMI Heating", "Apollo", "30/50b", "4178954", "", "1990", "1", "2", "1", "1", "0", "", "", "1", "2", "1", "8.8", "14.7", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "1", "60", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1079, "brand_name": "Potterton Myson Heating", "model_name": "Apollo", "model_qualifier": "30/50c", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 14.7, "final_year_of_manufacture": 1990, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001079", "000005", "0", "2010/Sep/13 17:03", "Potterton Myson Heating", "Potterton Myson Heating", "Apollo", "30/50c", "4178956", "", "1990", "1", "2", "1", "1", "0", "", "", "1", "1", "1", "8.8", "14.7", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "1", "60", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1080, "brand_name": "Thorn EMI Heating", "model_name": "Apollo", "model_qualifier": "30/50s", "winter_efficiency_pct": 73.0, "summer_efficiency_pct": 63.0, "comparative_hot_water_efficiency_pct": 45.9, "output_kw_max": 14.7, "final_year_of_manufacture": 1990, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001080", "000005", "0", "2015/Jul/21 14:15", "Thorn EMI Heating", "Thorn EMI Heating", "Apollo", "30/50s", "4149406", "", "1990", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "8.8", "14.7", "", "", "73.0", "63.0", "", "45.9", "", "3", "", "", "0", "2", "1", "60", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1084, "brand_name": "Thorn EMI Heating", "model_name": "Apollo", "model_qualifier": "50/65b", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 19.1, "final_year_of_manufacture": 1990, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001084", "000005", "0", "2010/Sep/13 17:03", "Thorn EMI Heating", "Thorn EMI Heating", "Apollo", "50/65b", "4178967", "", "1990", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "19.1", "19.1", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1085, "brand_name": "Thorn EMI Heating", "model_name": "Apollo", "model_qualifier": "50/65c", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 19.1, "final_year_of_manufacture": 1990, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001085", "000005", "0", "2010/Sep/13 17:03", "Thorn EMI Heating", "Thorn EMI Heating", "Apollo", "50/65c", "4178968", "", "1990", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "14.7", "19.1", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1086, "brand_name": "Thorn EMI Heating", "model_name": "Apollo", "model_qualifier": "50/80b", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 23.4, "final_year_of_manufacture": 1983, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001086", "000005", "0", "2010/Sep/13 17:03", "Thorn EMI Heating", "Thorn EMI Heating", "Apollo", "50/80b", "4178963", "", "1983", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "23.4", "23.4", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1087, "brand_name": "Thorn EMI Heating", "model_name": "Apollo", "model_qualifier": "50/80c", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 23.4, "final_year_of_manufacture": 1983, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001087", "000005", "0", "2010/Sep/13 17:03", "Thorn EMI Heating", "Thorn EMI Heating", "Apollo", "50/80c", "4178964", "", "1983", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "23.4", "23.4", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1088, "brand_name": "Thorn EMI Heating", "model_name": "Apollo", "model_qualifier": "65/80b", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 23.4, "final_year_of_manufacture": 1990, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001088", "000005", "0", "2010/Sep/13 17:03", "Thorn EMI Heating", "Thorn EMI Heating", "Apollo", "65/80b", "4178969", "", "1990", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "23.4", "23.4", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1089, "brand_name": "Thorn EMI Heating", "model_name": "Apollo", "model_qualifier": "65/80c", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 23.4, "final_year_of_manufacture": 1990, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001089", "000005", "0", "2010/Sep/13 17:03", "Thorn EMI Heating", "Thorn EMI Heating", "Apollo", "65/80c", "4178970", "", "1990", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "23.4", "23.4", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1090, "brand_name": "Potterton Myson Heating", "model_name": "Apollo Fanfare", "model_qualifier": "15/30", "winter_efficiency_pct": 73.0, "summer_efficiency_pct": 63.0, "comparative_hot_water_efficiency_pct": 45.9, "output_kw_max": 8.8, "final_year_of_manufacture": 1987, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001090", "000005", "0", "2015/Jul/21 14:15", "Potterton Myson Heating", "Potterton Myson Heating", "Apollo Fanfare", "15/30", "4178971", "", "1987", "1", "0", "0", "1", "0", "", "", "1", "2", "2", "8.8", "8.8", "", "", "73.0", "63.0", "", "45.9", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1091, "brand_name": "Potterton Myson Heating", "model_name": "Apollo Fanfare", "model_qualifier": "15/30i", "winter_efficiency_pct": 73.0, "summer_efficiency_pct": 63.0, "comparative_hot_water_efficiency_pct": 45.9, "output_kw_max": 8.8, "final_year_of_manufacture": 1987, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001091", "000005", "0", "2015/Jul/21 14:15", "Potterton Myson Heating", "Potterton Myson Heating", "Apollo Fanfare", "15/30i", "4178973", "", "1987", "1", "0", "0", "1", "0", "", "", "1", "2", "2", "8.8", "8.8", "", "", "73.0", "63.0", "", "45.9", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1092, "brand_name": "Thorn EMI Heating", "model_name": "Apollo Fanfare", "model_qualifier": "15/30s", "winter_efficiency_pct": 73.0, "summer_efficiency_pct": 63.0, "comparative_hot_water_efficiency_pct": 45.9, "output_kw_max": 8.8, "final_year_of_manufacture": 1990, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001092", "000005", "0", "2015/Jul/21 14:15", "Thorn EMI Heating", "Thorn EMI Heating", "Apollo Fanfare", "15/30s", "4149405", "", "1990", "1", "0", "0", "1", "0", "", "", "1", "2", "2", "8.8", "8.8", "", "", "73.0", "63.0", "", "45.9", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1093, "brand_name": "Thorn EMI Heating", "model_name": "Apollo Fanfare", "model_qualifier": "15/30si", "winter_efficiency_pct": 73.0, "summer_efficiency_pct": 63.0, "comparative_hot_water_efficiency_pct": 45.9, "output_kw_max": 8.8, "final_year_of_manufacture": 1990, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001093", "000005", "0", "2015/Jul/21 14:15", "Thorn EMI Heating", "Thorn EMI Heating", "Apollo Fanfare", "15/30si", "4179503", "", "1990", "1", "0", "0", "1", "0", "", "", "1", "2", "2", "8.8", "8.8", "", "", "73.0", "63.0", "", "45.9", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1094, "brand_name": "Potterton Myson Heating", "model_name": "Apollo Fanfare", "model_qualifier": "30/50", "winter_efficiency_pct": 73.0, "summer_efficiency_pct": 63.0, "comparative_hot_water_efficiency_pct": 45.9, "output_kw_max": 14.7, "final_year_of_manufacture": 1987, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001094", "000005", "0", "2015/Jul/21 14:15", "Potterton Myson Heating", "Potterton Myson Heating", "Apollo Fanfare", "30/50", "4178972", "", "1987", "1", "0", "0", "1", "0", "", "", "1", "2", "2", "14.7", "14.7", "", "", "73.0", "63.0", "", "45.9", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1095, "brand_name": "Potterton Myson Heating", "model_name": "Apollo Fanfare", "model_qualifier": "30/50i", "winter_efficiency_pct": 73.0, "summer_efficiency_pct": 63.0, "comparative_hot_water_efficiency_pct": 45.9, "output_kw_max": 14.7, "final_year_of_manufacture": 1987, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001095", "000005", "0", "2015/Jul/21 14:15", "Potterton Myson Heating", "Potterton Myson Heating", "Apollo Fanfare", "30/50i", "4178974", "", "1987", "1", "0", "0", "1", "0", "", "", "1", "2", "2", "14.7", "14.7", "", "", "73.0", "63.0", "", "45.9", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1096, "brand_name": "Thorn EMI Heating", "model_name": "Apollo Fanfare", "model_qualifier": "30/50si", "winter_efficiency_pct": 73.0, "summer_efficiency_pct": 63.0, "comparative_hot_water_efficiency_pct": 45.9, "output_kw_max": 14.7, "final_year_of_manufacture": 1990, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001096", "000005", "0", "2015/Jul/21 14:15", "Thorn EMI Heating", "Thorn EMI Heating", "Apollo Fanfare", "30/50si", "4179504", "", "1990", "1", "0", "0", "1", "0", "", "", "1", "2", "2", "14.7", "14.7", "", "", "73.0", "63.0", "", "45.9", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1097, "brand_name": "Thorn EMI Heating", "model_name": "Apollo Fanfare", "model_qualifier": "40si", "winter_efficiency_pct": 73.0, "summer_efficiency_pct": 63.0, "comparative_hot_water_efficiency_pct": 45.9, "output_kw_max": 11.7, "final_year_of_manufacture": 1990, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001097", "000005", "0", "2015/Jul/21 14:15", "Thorn EMI Heating", "Thorn EMI Heating", "Apollo Fanfare", "40si", "4179505", "", "1990", "1", "0", "0", "1", "0", "", "", "1", "2", "2", "11.7", "11.7", "", "", "73.0", "63.0", "", "45.9", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1098, "brand_name": "Thorn EMI Heating", "model_name": "Apollo Fanfare", "model_qualifier": "50/65si", "winter_efficiency_pct": 73.0, "summer_efficiency_pct": 63.0, "comparative_hot_water_efficiency_pct": 45.9, "output_kw_max": 19.1, "final_year_of_manufacture": 1990, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001098", "000005", "0", "2015/Jul/21 14:15", "Thorn EMI Heating", "Thorn EMI Heating", "Apollo Fanfare", "50/65si", "4178976", "", "1990", "1", "0", "0", "1", "0", "", "", "1", "2", "2", "19.1", "19.1", "", "", "73.0", "63.0", "", "45.9", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1099, "brand_name": "Thorn EMI Heating", "model_name": "Apollo Fanfare", "model_qualifier": "65/80si", "winter_efficiency_pct": 73.0, "summer_efficiency_pct": 63.0, "comparative_hot_water_efficiency_pct": 45.9, "output_kw_max": 23.4, "final_year_of_manufacture": 1990, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001099", "000005", "0", "2015/Jul/21 14:15", "Thorn EMI Heating", "Thorn EMI Heating", "Apollo Fanfare", "65/80si", "4178975", "", "1990", "1", "0", "0", "1", "0", "", "", "1", "2", "2", "23.4", "23.4", "", "", "73.0", "63.0", "", "45.9", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1100, "brand_name": "Thorn EMI Heating", "model_name": "Gemini", "model_qualifier": "wm", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 57.0, "comparative_hot_water_efficiency_pct": 39.7, "output_kw_max": 14.7, "final_year_of_manufacture": 1988, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001100", "000005", "0", "2010/Sep/13 17:03", "Thorn EMI Heating", "Thorn EMI Heating", "Gemini", "wm", "4778901", "", "1988", "1", "0", "0", "2", "0", "", "", "1", "2", "1", "14.7", "14.7", "", "", "66.0", "57.0", "", "39.7", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1102, "brand_name": "Thorn EMI Heating", "model_name": "International", "model_qualifier": "m42bf", "winter_efficiency_pct": 56.0, "summer_efficiency_pct": 46.0, "comparative_hot_water_efficiency_pct": 33.5, "output_kw_max": 11.7, "final_year_of_manufacture": 1976, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001102", "000005", "0", "2010/Sep/13 17:03", "Thorn EMI Heating", "Thorn EMI Heating", "International", "m42bf", "4178904", "", "1976", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "11.7", "11.7", "", "", "56.0", "46.0", "", "33.5", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1104, "brand_name": "Thorn EMI Heating", "model_name": "International", "model_qualifier": "m42cf", "winter_efficiency_pct": 56.0, "summer_efficiency_pct": 46.0, "comparative_hot_water_efficiency_pct": 33.5, "output_kw_max": 11.7, "final_year_of_manufacture": 1976, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001104", "000005", "0", "2010/Sep/13 17:03", "Thorn EMI Heating", "Thorn EMI Heating", "International", "m42cf", "4178908", "", "1976", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "11.7", "11.7", "", "", "56.0", "46.0", "", "33.5", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1106, "brand_name": "Thorn EMI Heating", "model_name": "International", "model_qualifier": "m54bf", "winter_efficiency_pct": 56.0, "summer_efficiency_pct": 46.0, "comparative_hot_water_efficiency_pct": 33.5, "output_kw_max": 14.7, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001106", "000005", "0", "2010/Sep/13 17:03", "Thorn EMI Heating", "Thorn EMI Heating", "International", "m54bf", "4178911", "", "obsolete", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "14.7", "14.7", "", "", "56.0", "46.0", "", "33.5", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1108, "brand_name": "Thorn EMI Heating", "model_name": "International", "model_qualifier": "m54cf", "winter_efficiency_pct": 56.0, "summer_efficiency_pct": 46.0, "comparative_hot_water_efficiency_pct": 33.5, "output_kw_max": 14.7, "final_year_of_manufacture": 1976, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001108", "000005", "0", "2010/Sep/13 17:03", "Thorn EMI Heating", "Thorn EMI Heating", "International", "m54cf", "4178903", "", "1976", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "14.7", "14.7", "", "", "56.0", "46.0", "", "33.5", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1109, "brand_name": "Potterton Myson Heating", "model_name": "Marathon", "model_qualifier": "100b", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 27.8, "final_year_of_manufacture": 1988, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001109", "000005", "0", "2010/Sep/13 17:03", "Potterton Myson Heating", "Potterton Myson Heating", "Marathon", "100b", "4178985", "", "1988", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "27.8", "27.8", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1110, "brand_name": "Potterton Myson Heating", "model_name": "Marathon", "model_qualifier": "100c", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 27.8, "final_year_of_manufacture": 1988, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001110", "000005", "0", "2010/Sep/13 17:03", "Potterton Myson Heating", "Potterton Myson Heating", "Marathon", "100c", "4178991", "", "1988", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "27.8", "27.8", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1111, "brand_name": "Potterton Myson Heating", "model_name": "Marathon", "model_qualifier": "120/150c", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 41.47, "final_year_of_manufacture": 1988, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001111", "000005", "0", "2010/Sep/13 17:03", "Potterton Myson Heating", "Potterton Myson Heating", "Marathon", "120/150c", "4178952", "", "1988", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "41.47", "41.47", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1112, "brand_name": "Thorn EMI Heating", "model_name": "Marathon", "model_qualifier": "30/42b", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 12.3, "final_year_of_manufacture": 1983, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001112", "000005", "0", "2010/Sep/13 17:03", "Thorn EMI Heating", "Thorn EMI Heating", "Marathon", "30/42b", "4178945", "", "1983", "1", "1", "1", "1", "0", "", "", "1", "2", "1", "8.8", "12.3", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "1", "20", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1113, "brand_name": "Thorn EMI Heating", "model_name": "Marathon", "model_qualifier": "30/42c", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 12.3, "final_year_of_manufacture": 1983, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001113", "000005", "0", "2010/Sep/13 17:03", "Thorn EMI Heating", "Thorn EMI Heating", "Marathon", "30/42c", "4178944", "", "1983", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "8.8", "12.3", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "1", "20", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1114, "brand_name": "Potterton Myson Heating", "model_name": "Marathon", "model_qualifier": "40c", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 11.7, "final_year_of_manufacture": 1988, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001114", "000005", "0", "2010/Sep/13 17:03", "Potterton Myson Heating", "Potterton Myson Heating", "Marathon", "40c", "4178986", "", "1988", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "11.7", "11.7", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1115, "brand_name": "Thorn EMI Heating", "model_name": "Marathon", "model_qualifier": "44/54b", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 15.8, "final_year_of_manufacture": 1983, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001115", "000005", "0", "2010/Sep/13 17:03", "Thorn EMI Heating", "Thorn EMI Heating", "Marathon", "44/54b", "4178947", "", "1983", "1", "1", "1", "1", "0", "", "", "1", "2", "1", "12.9", "15.8", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "1", "20", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1116, "brand_name": "Thorn EMI Heating", "model_name": "Marathon", "model_qualifier": "44/54c", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 15.8, "final_year_of_manufacture": 1983, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001116", "000005", "0", "2010/Sep/13 17:03", "Thorn EMI Heating", "Thorn EMI Heating", "Marathon", "44/54c", "4178946", "", "1983", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "12.9", "15.8", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "1", "20", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1117, "brand_name": "Potterton Myson Heating", "model_name": "Marathon", "model_qualifier": "50c", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 14.7, "final_year_of_manufacture": 1988, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001117", "000005", "0", "2010/Sep/13 17:03", "Potterton Myson Heating", "Potterton Myson Heating", "Marathon", "50c", "4178987", "", "1988", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "14.7", "14.7", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1118, "brand_name": "Thorn EMI Heating", "model_name": "Marathon", "model_qualifier": "56/76b", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 21.1, "final_year_of_manufacture": 1983, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001118", "000005", "0", "2010/Sep/13 17:03", "Thorn EMI Heating", "Thorn EMI Heating", "Marathon", "56/76b", "4178949", "", "1983", "1", "1", "1", "1", "0", "", "", "1", "2", "1", "21.1", "21.1", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "1", "20", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1119, "brand_name": "Thorn EMI Heating", "model_name": "Marathon", "model_qualifier": "56/76c", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 22.3, "final_year_of_manufacture": 1983, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001119", "000005", "0", "2010/Sep/13 17:03", "Thorn EMI Heating", "Thorn EMI Heating", "Marathon", "56/76c", "4178948", "", "1983", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "16.4", "22.3", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "1", "20", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1120, "brand_name": "Potterton Myson Heating", "model_name": "Marathon", "model_qualifier": "60b", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 17.6, "final_year_of_manufacture": 1988, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001120", "000005", "0", "2010/Sep/13 17:03", "Potterton Myson Heating", "Potterton Myson Heating", "Marathon", "60b", "4178982", "", "1988", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "17.6", "17.6", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1121, "brand_name": "Potterton Myson Heating", "model_name": "Marathon", "model_qualifier": "60c", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 17.6, "final_year_of_manufacture": 1988, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001121", "000005", "0", "2010/Sep/13 17:03", "Potterton Myson Heating", "Potterton Myson Heating", "Marathon", "60c", "4178988", "", "1988", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "17.6", "17.6", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1122, "brand_name": "Potterton Myson Heating", "model_name": "Marathon", "model_qualifier": "70b", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 20.5, "final_year_of_manufacture": 1988, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001122", "000005", "0", "2010/Sep/13 17:03", "Potterton Myson Heating", "Potterton Myson Heating", "Marathon", "70b", "4178983", "", "1988", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "20.5", "20.5", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1123, "brand_name": "Potterton Myson Heating", "model_name": "Marathon", "model_qualifier": "70c", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 20.5, "final_year_of_manufacture": 1988, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001123", "000005", "0", "2010/Sep/13 17:03", "Potterton Myson Heating", "Potterton Myson Heating", "Marathon", "70c", "4178989", "", "1988", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "20.5", "20.5", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1124, "brand_name": "Thorn EMI Heating", "model_name": "Marathon", "model_qualifier": "80/100b", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 29.3, "final_year_of_manufacture": 1983, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001124", "000005", "0", "2010/Sep/13 17:03", "Thorn EMI Heating", "Thorn EMI Heating", "Marathon", "80/100b", "4178951", "", "1983", "1", "1", "1", "1", "0", "", "", "1", "2", "1", "23.4", "29.3", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "1", "20", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1125, "brand_name": "Thorn EMI Heating", "model_name": "Marathon", "model_qualifier": "80/100c", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 29.3, "final_year_of_manufacture": 1983, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001125", "000005", "0", "2010/Sep/13 17:03", "Thorn EMI Heating", "Thorn EMI Heating", "Marathon", "80/100c", "4178950", "", "1983", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "23.4", "29.3", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "1", "20", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1126, "brand_name": "Potterton Myson Heating", "model_name": "Marathon", "model_qualifier": "80b", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 23.5, "final_year_of_manufacture": 1988, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001126", "000005", "0", "2010/Sep/13 17:03", "Potterton Myson Heating", "Potterton Myson Heating", "Marathon", "80b", "4178984", "", "1988", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "23.5", "23.5", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1127, "brand_name": "Potterton Myson Heating", "model_name": "Marathon", "model_qualifier": "80c", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 23.5, "final_year_of_manufacture": 1988, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001127", "000005", "0", "2010/Sep/13 17:03", "Potterton Myson Heating", "Potterton Myson Heating", "Marathon", "80c", "4178990", "", "1988", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "23.5", "23.5", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1128, "brand_name": "Myson Combustion Products", "model_name": "Midas", "model_qualifier": "b", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 39.2, "output_kw_max": 20.5, "final_year_of_manufacture": 1991, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001128", "000005", "0", "2010/Sep/13 17:03", "Myson Combustion Products", "Myson Combustion Products", "Midas", "b", "4783801", "", "1991", "1", "2", "1", "2", "0", "", "", "1", "2", "1", "20.5", "20.5", "", "", "66.0", "56.0", "", "39.2", "", "3", "", "", "0", "2", "2", "20", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1129, "brand_name": "Myson Combustion Products", "model_name": "Midas", "model_qualifier": "bf", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 39.2, "output_kw_max": 20.5, "final_year_of_manufacture": 1995, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001129", "000005", "0", "2010/Sep/13 17:03", "Myson Combustion Products", "Myson Combustion Products", "Midas", "bf", "4749403", "", "1995", "1", "2", "1", "2", "0", "", "", "1", "2", "1", "20.5", "20.5", "", "", "66.0", "56.0", "", "39.2", "", "3", "", "", "0", "2", "2", "20", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1130, "brand_name": "Myson Combustion Products", "model_name": "Midas", "model_qualifier": "sfi", "winter_efficiency_pct": 71.0, "summer_efficiency_pct": 61.0, "comparative_hot_water_efficiency_pct": 42.8, "output_kw_max": 29.3, "final_year_of_manufacture": 1995, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001130", "000005", "0", "2010/Sep/13 17:03", "Myson Combustion Products", "Myson Combustion Products", "Midas", "sfi", "4749404", "", "1995", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "29.3", "29.3", "", "", "71.0", "61.0", "", "42.8", "", "3", "", "", "0", "1", "2", "80", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1131, "brand_name": "Myson Combustion Products", "model_name": "Midas", "model_qualifier": "si", "winter_efficiency_pct": 71.0, "summer_efficiency_pct": 61.0, "comparative_hot_water_efficiency_pct": 42.8, "output_kw_max": 29.3, "final_year_of_manufacture": 1991, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001131", "000005", "0", "2010/Sep/13 17:03", "Myson Combustion Products", "Myson Combustion Products", "Midas", "si", "4749402", "", "1991", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "29.3", "29.3", "", "", "71.0", "61.0", "", "42.8", "", "3", "", "", "0", "1", "2", "80", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1132, "brand_name": "Potterton Myson Heating", "model_name": "Olympic", "model_qualifier": "20/35b", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 10.26, "final_year_of_manufacture": 1987, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001132", "000005", "0", "2010/Sep/13 17:03", "Potterton Myson Heating", "Potterton Myson Heating", "Olympic", "20/35b", "4178921", "", "1987", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "10.26", "10.26", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1133, "brand_name": "Potterton Myson Heating", "model_name": "Olympic", "model_qualifier": "20/35cf", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 10.26, "final_year_of_manufacture": 1987, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001133", "000005", "0", "2010/Sep/13 17:03", "Potterton Myson Heating", "Potterton Myson Heating", "Olympic", "20/35cf", "4178942", "", "1987", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "10.26", "10.26", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1134, "brand_name": "Potterton Myson Heating", "model_name": "Olympic", "model_qualifier": "20/35f", "winter_efficiency_pct": 69.0, "summer_efficiency_pct": 59.0, "comparative_hot_water_efficiency_pct": 43.0, "output_kw_max": 10.26, "final_year_of_manufacture": 1987, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001134", "000005", "0", "2010/Sep/13 17:03", "Potterton Myson Heating", "Potterton Myson Heating", "Olympic", "20/35f", "4178965", "", "1987", "1", "0", "0", "1", "0", "", "", "1", "2", "2", "10.26", "10.26", "", "", "69.0", "59.0", "", "43.0", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1135, "brand_name": "Potterton Myson Heating", "model_name": "Olympic", "model_qualifier": "38/50b", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 14.66, "final_year_of_manufacture": 1987, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001135", "000005", "0", "2010/Sep/13 17:03", "Potterton Myson Heating", "Potterton Myson Heating", "Olympic", "38/50b", "4178920", "", "1987", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "14.66", "14.66", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1136, "brand_name": "Potterton Myson Heating", "model_name": "Olympic", "model_qualifier": "38/50cf", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 14.66, "final_year_of_manufacture": 1987, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001136", "000005", "0", "2010/Sep/13 17:03", "Potterton Myson Heating", "Potterton Myson Heating", "Olympic", "38/50cf", "4178943", "", "1987", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "14.66", "14.66", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1137, "brand_name": "Potterton Myson Heating", "model_name": "Olympic", "model_qualifier": "38/50f", "winter_efficiency_pct": 69.0, "summer_efficiency_pct": 59.0, "comparative_hot_water_efficiency_pct": 43.0, "output_kw_max": 14.65, "final_year_of_manufacture": 1987, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001137", "000005", "0", "2010/Sep/13 17:03", "Potterton Myson Heating", "Potterton Myson Heating", "Olympic", "38/50f", "4178966", "", "1987", "1", "0", "0", "1", "0", "", "", "1", "2", "2", "14.65", "14.65", "", "", "69.0", "59.0", "", "43.0", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1138, "brand_name": "Thorn EMI Heating", "model_name": "Orion", "model_qualifier": "30b", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 8.8, "final_year_of_manufacture": 1993, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001138", "000005", "0", "2010/Sep/13 17:03", "Thorn EMI Heating", "Thorn EMI Heating", "Orion", "30b", "4178994", "", "1993", "1", "2", "1", "1", "0", "", "", "1", "2", "1", "8.8", "8.8", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "1", "20", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1139, "brand_name": "Thorn EMI Heating", "model_name": "Orion", "model_qualifier": "40b", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 11.7, "final_year_of_manufacture": 1993, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001139", "000005", "0", "2010/Sep/13 17:03", "Thorn EMI Heating", "Thorn EMI Heating", "Orion", "40b", "4178995", "", "1993", "1", "2", "1", "1", "0", "", "", "1", "2", "1", "11.7", "11.7", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "1", "20", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1140, "brand_name": "Thorn EMI Heating", "model_name": "Orion", "model_qualifier": "50b", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 14.7, "final_year_of_manufacture": 1993, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001140", "000005", "0", "2010/Sep/13 17:03", "Thorn EMI Heating", "Thorn EMI Heating", "Orion", "50b", "4178996", "", "1993", "1", "2", "1", "1", "0", "", "", "1", "2", "1", "14.7", "14.7", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "1", "20", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1141, "brand_name": "Thorn EMI Heating", "model_name": "Orion", "model_qualifier": "60b", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 17.6, "final_year_of_manufacture": 1993, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001141", "000005", "0", "2010/Sep/13 17:03", "Thorn EMI Heating", "Thorn EMI Heating", "Orion", "60b", "4178997", "", "1993", "1", "2", "1", "1", "0", "", "", "1", "2", "1", "17.6", "17.6", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "1", "20", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1142, "brand_name": "Thorn EMI Heating", "model_name": "Orion", "model_qualifier": "75si", "winter_efficiency_pct": 69.0, "summer_efficiency_pct": 59.0, "comparative_hot_water_efficiency_pct": 43.0, "output_kw_max": 21.9, "final_year_of_manufacture": 1993, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001142", "000005", "0", "2010/Sep/13 17:03", "Thorn EMI Heating", "Thorn EMI Heating", "Orion", "75si", "4149421", "", "1993", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "21.9", "21.9", "", "", "69.0", "59.0", "", "43.0", "", "3", "", "", "0", "1", "1", "80", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1143, "brand_name": "Thorn EMI Heating", "model_name": "Orion Fanfare", "model_qualifier": "30si", "winter_efficiency_pct": 69.0, "summer_efficiency_pct": 59.0, "comparative_hot_water_efficiency_pct": 43.0, "output_kw_max": 8.8, "final_year_of_manufacture": 1993, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001143", "000005", "0", "2010/Sep/13 17:03", "Thorn EMI Heating", "Thorn EMI Heating", "Orion Fanfare", "30si", "4179506", "", "1993", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "8.8", "8.8", "", "", "69.0", "59.0", "", "43.0", "", "3", "", "", "0", "1", "1", "60", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1144, "brand_name": "Thorn EMI Heating", "model_name": "Orion Fanfare", "model_qualifier": "40si", "winter_efficiency_pct": 69.0, "summer_efficiency_pct": 59.0, "comparative_hot_water_efficiency_pct": 43.0, "output_kw_max": 11.7, "final_year_of_manufacture": 1993, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001144", "000005", "0", "2010/Sep/13 17:03", "Thorn EMI Heating", "Thorn EMI Heating", "Orion Fanfare", "40si", "4179507", "", "1993", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "11.7", "11.7", "", "", "69.0", "59.0", "", "43.0", "", "3", "", "", "0", "1", "1", "60", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1145, "brand_name": "Thorn EMI Heating", "model_name": "Orion Fanfare", "model_qualifier": "50si", "winter_efficiency_pct": 69.0, "summer_efficiency_pct": 59.0, "comparative_hot_water_efficiency_pct": 43.0, "output_kw_max": 14.7, "final_year_of_manufacture": 1993, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001145", "000005", "0", "2010/Sep/13 17:03", "Thorn EMI Heating", "Thorn EMI Heating", "Orion Fanfare", "50si", "4179508", "", "1993", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "14.7", "14.7", "", "", "69.0", "59.0", "", "43.0", "", "3", "", "", "0", "1", "1", "60", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1146, "brand_name": "Thorn EMI Heating", "model_name": "Orion Fanfare", "model_qualifier": "60si", "winter_efficiency_pct": 69.0, "summer_efficiency_pct": 59.0, "comparative_hot_water_efficiency_pct": 43.0, "output_kw_max": 17.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001146", "000005", "0", "2010/Sep/13 17:03", "Thorn EMI Heating", "Thorn EMI Heating", "Orion Fanfare", "60si", "4179509", "", "obsolete", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "17.6", "17.6", "", "", "69.0", "59.0", "", "43.0", "", "3", "", "", "0", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1147, "brand_name": "Thorn EMI Heating", "model_name": "Thorn Harcal Havana", "model_qualifier": "", "winter_efficiency_pct": 65.0, "summer_efficiency_pct": 53.0, "comparative_hot_water_efficiency_pct": 38.9, "output_kw_max": 10.9, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001147", "000005", "0", "2010/Sep/13 17:03", "Thorn EMI Heating", "Thorn EMI Heating", "Thorn Harcal Havana", "", "", "", "obsolete", "4", "0", "0", "1", "0", "", "", "1", "1", "1", "10.9", "10.9", "", "", "65.0", "53.0", "", "38.9", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1148, "brand_name": "Thorn EMI Heating", "model_name": "Thorn Harcal", "model_qualifier": "200", "winter_efficiency_pct": 65.0, "summer_efficiency_pct": 53.0, "comparative_hot_water_efficiency_pct": 38.9, "output_kw_max": 10.9, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001148", "000005", "0", "2010/Sep/13 17:03", "Thorn EMI Heating", "Thorn EMI Heating", "Thorn Harcal", "200", "", "", "obsolete", "4", "0", "0", "1", "0", "", "", "1", "1", "1", "10.9", "10.9", "", "", "65.0", "53.0", "", "38.9", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1150, "brand_name": "Thorn EMI Heating", "model_name": "Thorn Janitor", "model_qualifier": "ODY-3", "winter_efficiency_pct": 65.0, "summer_efficiency_pct": 53.0, "comparative_hot_water_efficiency_pct": 38.9, "output_kw_max": 22.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001150", "000005", "0", "2010/Sep/13 17:03", "Thorn EMI Heating", "Thorn EMI Heating", "Thorn Janitor", "ODY-3", "", "", "obsolete", "4", "0", "0", "1", "0", "", "", "1", "2", "2", "17.6", "22.0", "", "", "65.0", "53.0", "", "38.9", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1151, "brand_name": "Thorn EMI Heating", "model_name": "Thorn Janitor", "model_qualifier": "OV-45", "winter_efficiency_pct": 65.0, "summer_efficiency_pct": 53.0, "comparative_hot_water_efficiency_pct": 38.9, "output_kw_max": 13.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001151", "000005", "0", "2010/Sep/13 17:03", "Thorn EMI Heating", "Thorn EMI Heating", "Thorn Janitor", "OV-45", "", "", "obsolete", "4", "0", "0", "1", "0", "", "", "1", "1", "1", "13.2", "13.2", "", "", "65.0", "53.0", "", "38.9", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1152, "brand_name": "Thorn EMI Heating", "model_name": "Harcal", "model_qualifier": "260", "winter_efficiency_pct": 65.0, "summer_efficiency_pct": 53.0, "comparative_hot_water_efficiency_pct": 38.9, "output_kw_max": 13.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001152", "000005", "0", "2010/Sep/13 17:03", "Thorn EMI Heating", "Thorn EMI Heating", "Harcal", "260", "", "", "obsolete", "4", "0", "0", "1", "0", "", "", "1", "1", "1", "13.2", "13.2", "", "", "65.0", "53.0", "", "38.9", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1159, "brand_name": "Trianco", "model_name": "Trianco", "model_qualifier": "firelite", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": null, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001159", "000062", "0", "2010/Sep/13 17:03", "Trianco Redfyre", "Trianco", "Trianco", "firelite", "3789803", "", "obsolete", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "", "", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1160, "brand_name": "Trianco", "model_name": "Triancogas", "model_qualifier": "25/40", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": null, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001160", "000062", "0", "2010/Sep/13 17:03", "Trianco Redfyre", "Trianco", "Triancogas", "25/40", "4489801", "", "obsolete", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "", "", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1161, "brand_name": "Trianco", "model_name": "Triancogas", "model_qualifier": "35/50", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": null, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001161", "000062", "0", "2010/Sep/13 17:03", "Trianco Redfyre", "Trianco", "Triancogas", "35/50", "4489802", "", "obsolete", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "", "", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1162, "brand_name": "Trianco", "model_name": "Tristar", "model_qualifier": "35f", "winter_efficiency_pct": 73.0, "summer_efficiency_pct": 63.0, "comparative_hot_water_efficiency_pct": 45.9, "output_kw_max": 10.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001162", "000062", "0", "2015/Jul/21 14:15", "Trianco Redfyre", "Trianco", "Tristar", "35f", "4189844", "", "obsolete", "1", "0", "0", "1", "0", "", "", "1", "2", "2", "10.3", "10.3", "", "", "73.0", "63.0", "", "45.9", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1163, "brand_name": "Trianco", "model_name": "Tristar", "model_qualifier": "45f", "winter_efficiency_pct": 73.0, "summer_efficiency_pct": 63.0, "comparative_hot_water_efficiency_pct": 45.9, "output_kw_max": 13.19, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001163", "000062", "0", "2015/Jul/21 14:15", "Trianco Redfyre", "Trianco", "Tristar", "45f", "4189845", "", "obsolete", "1", "0", "0", "1", "0", "", "", "1", "2", "2", "13.19", "13.19", "", "", "73.0", "63.0", "", "45.9", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1164, "brand_name": "Trianco", "model_name": "Tristar", "model_qualifier": "52f", "winter_efficiency_pct": 73.0, "summer_efficiency_pct": 63.0, "comparative_hot_water_efficiency_pct": 45.9, "output_kw_max": 15.24, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001164", "000062", "0", "2015/Jul/21 14:15", "Trianco Redfyre", "Trianco", "Tristar", "52f", "4189846", "", "obsolete", "1", "0", "0", "1", "0", "", "", "1", "2", "2", "15.24", "15.24", "", "", "73.0", "63.0", "", "45.9", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1165, "brand_name": "Trianco", "model_name": "Tristar", "model_qualifier": "60f", "winter_efficiency_pct": 73.0, "summer_efficiency_pct": 63.0, "comparative_hot_water_efficiency_pct": 45.9, "output_kw_max": 17.58, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001165", "000062", "0", "2015/Jul/21 14:15", "Trianco Redfyre", "Trianco", "Tristar", "60f", "4189847", "", "obsolete", "1", "0", "0", "1", "0", "", "", "1", "2", "2", "17.58", "17.58", "", "", "73.0", "63.0", "", "45.9", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1166, "brand_name": "Trianco", "model_name": "Tristar", "model_qualifier": "80f", "winter_efficiency_pct": 73.0, "summer_efficiency_pct": 63.0, "comparative_hot_water_efficiency_pct": 45.9, "output_kw_max": 23.44, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001166", "000062", "0", "2015/Jul/21 14:15", "Trianco Redfyre", "Trianco", "Tristar", "80f", "4189848", "", "obsolete", "1", "0", "0", "1", "0", "", "", "1", "2", "2", "23.44", "23.44", "", "", "73.0", "63.0", "", "45.9", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1167, "brand_name": "Trianco", "model_name": "Valor", "model_qualifier": "Homeflame Super", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": null, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001167", "000062", "0", "2010/Sep/13 17:03", "Trianco Redfyre", "Trianco", "Valor", "Homeflame Super", "3789801", "", "obsolete", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "", "", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1168, "brand_name": "Trianco", "model_name": "Valor", "model_qualifier": "Majestic", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": null, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001168", "000062", "0", "2010/Sep/13 17:03", "Trianco Redfyre", "Trianco", "Valor", "Majestic", "3789802", "", "obsolete", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "", "", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1169, "brand_name": "Trianco", "model_name": "Wm", "model_qualifier": "20/30rs", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 8.8, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001169", "000062", "0", "2010/Sep/13 17:03", "Trianco Redfyre", "Trianco", "Wm", "20/30rs", "4189835", "", "obsolete", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "8.8", "8.8", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1170, "brand_name": "Trianco", "model_name": "Wm", "model_qualifier": "20/35f", "winter_efficiency_pct": 73.0, "summer_efficiency_pct": 63.0, "comparative_hot_water_efficiency_pct": 45.9, "output_kw_max": 10.25, "final_year_of_manufacture": 1990, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001170", "000062", "0", "2015/Jul/21 14:15", "Trianco Redfyre", "Trianco", "Wm", "20/35f", "4189840", "", "1990", "1", "0", "0", "1", "0", "", "", "1", "2", "2", "10.25", "10.25", "", "", "73.0", "63.0", "", "45.9", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1171, "brand_name": "Trianco", "model_name": "Wm", "model_qualifier": "25/45rs", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 13.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001171", "000062", "0", "2010/Sep/13 17:03", "Trianco Redfyre", "Trianco", "Wm", "25/45rs", "4189829", "", "obsolete", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "13.2", "13.2", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1172, "brand_name": "Trianco", "model_name": "Wm", "model_qualifier": "30/40rs", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 11.7, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001172", "000062", "0", "2010/Sep/13 17:03", "Trianco Redfyre", "Trianco", "Wm", "30/40rs", "4189836", "", "obsolete", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "11.7", "11.7", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1173, "brand_name": "Trianco", "model_name": "Wm", "model_qualifier": "30/50f", "winter_efficiency_pct": 73.0, "summer_efficiency_pct": 63.0, "comparative_hot_water_efficiency_pct": 45.9, "output_kw_max": 14.65, "final_year_of_manufacture": 1992, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001173", "000062", "0", "2015/Jul/21 14:15", "Trianco Redfyre", "Trianco", "Wm", "30/50f", "4189832", "", "1992", "1", "0", "0", "1", "0", "", "", "1", "2", "2", "14.65", "14.65", "", "", "73.0", "63.0", "", "45.9", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1174, "brand_name": "Trianco", "model_name": "Wm", "model_qualifier": "35/50f", "winter_efficiency_pct": 73.0, "summer_efficiency_pct": 63.0, "comparative_hot_water_efficiency_pct": 45.9, "output_kw_max": 14.65, "final_year_of_manufacture": 1992, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001174", "000062", "0", "2015/Jul/21 14:15", "Trianco Redfyre", "Trianco", "Wm", "35/50f", "4189841", "", "1992", "1", "0", "0", "1", "0", "", "", "1", "2", "2", "14.65", "14.65", "", "", "73.0", "63.0", "", "45.9", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1175, "brand_name": "Trianco", "model_name": "Wm", "model_qualifier": "40/50rs", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 14.7, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001175", "000062", "0", "2010/Sep/13 17:03", "Trianco Redfyre", "Trianco", "Wm", "40/50rs", "4189837", "", "obsolete", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "14.7", "14.7", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1176, "brand_name": "Trianco", "model_name": "Wm", "model_qualifier": "45/60rs", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 17.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001176", "000062", "0", "2010/Sep/13 17:03", "Trianco Redfyre", "Trianco", "Wm", "45/60rs", "4189830", "", "obsolete", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "17.6", "17.6", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1177, "brand_name": "Trianco", "model_name": "Wm", "model_qualifier": "50/60rs", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 17.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001177", "000062", "0", "2010/Sep/13 17:03", "Trianco Redfyre", "Trianco", "Wm", "50/60rs", "4189838", "", "obsolete", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "17.6", "17.6", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1178, "brand_name": "Trianco", "model_name": "Wm", "model_qualifier": "50/65f", "winter_efficiency_pct": 73.0, "summer_efficiency_pct": 63.0, "comparative_hot_water_efficiency_pct": 45.9, "output_kw_max": 19.05, "final_year_of_manufacture": 1992, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001178", "000062", "0", "2015/Jul/21 14:15", "Trianco Redfyre", "Trianco", "Wm", "50/65f", "4189833", "", "1992", "1", "0", "0", "1", "0", "", "", "1", "2", "2", "19.05", "19.05", "", "", "73.0", "63.0", "", "45.9", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1179, "brand_name": "Trianco", "model_name": "Wm", "model_qualifier": "60/75rs", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 22.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001179", "000062", "0", "2010/Sep/13 17:03", "Trianco Redfyre", "Trianco", "Wm", "60/75rs", "4189831", "", "obsolete", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "22", "22", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1180, "brand_name": "Trianco", "model_name": "Wm", "model_qualifier": "65/80f", "winter_efficiency_pct": 73.0, "summer_efficiency_pct": 63.0, "comparative_hot_water_efficiency_pct": 45.9, "output_kw_max": 23.15, "final_year_of_manufacture": 1992, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001180", "000062", "0", "2015/Jul/21 14:15", "Trianco Redfyre", "Trianco", "Wm", "65/80f", "4189834", "", "1992", "1", "0", "0", "1", "0", "", "", "1", "2", "2", "23.15", "23.15", "", "", "73.0", "63.0", "", "45.9", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1181, "brand_name": "Trianco", "model_name": "TRO", "model_qualifier": "12/14 Mk3 CF", "winter_efficiency_pct": 70.0, "summer_efficiency_pct": 58.0, "comparative_hot_water_efficiency_pct": 42.6, "output_kw_max": 14.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001181", "000062", "0", "2010/Sep/13 17:03", "Trianco Redfyre", "Trianco", "TRO", "12/14 Mk3 CF", "", "", "obsolete", "4", "0", "0", "1", "0", "", "", "1", "2", "2", "12", "14", "", "", "70.0", "58.0", "", "42.6", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1182, "brand_name": "Trianco", "model_name": "TRO", "model_qualifier": "15/19 Mk3 CF", "winter_efficiency_pct": 70.0, "summer_efficiency_pct": 58.0, "comparative_hot_water_efficiency_pct": 42.6, "output_kw_max": 19.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001182", "000062", "0", "2010/Sep/13 17:03", "Trianco Redfyre", "Trianco", "TRO", "15/19 Mk3 CF", "", "", "obsolete", "4", "0", "0", "1", "0", "", "", "1", "2", "2", "15", "19", "", "", "70.0", "58.0", "", "42.6", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1183, "brand_name": "Trianco", "model_name": "TRO", "model_qualifier": "20/25 Mk3 CF", "winter_efficiency_pct": 70.0, "summer_efficiency_pct": 58.0, "comparative_hot_water_efficiency_pct": 42.6, "output_kw_max": 25.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001183", "000062", "0", "2010/Sep/13 17:03", "Trianco Redfyre", "Trianco", "TRO", "20/25 Mk3 CF", "", "", "obsolete", "4", "0", "0", "1", "0", "", "", "1", "2", "2", "20", "25", "", "", "70.0", "58.0", "", "42.6", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1184, "brand_name": "Trianco", "model_name": "TRO", "model_qualifier": "28/32 Mk3 CF", "winter_efficiency_pct": 70.0, "summer_efficiency_pct": 58.0, "comparative_hot_water_efficiency_pct": 42.6, "output_kw_max": 32.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001184", "000062", "0", "2010/Sep/13 17:03", "Trianco Redfyre", "Trianco", "TRO", "28/32 Mk3 CF", "", "", "obsolete", "4", "0", "0", "1", "0", "", "", "1", "2", "2", "28", "32", "", "", "70.0", "58.0", "", "42.6", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1185, "brand_name": "Trianco", "model_name": "TRO", "model_qualifier": "37/45 Mk3 CF", "winter_efficiency_pct": 70.0, "summer_efficiency_pct": 58.0, "comparative_hot_water_efficiency_pct": 42.6, "output_kw_max": 45.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001185", "000062", "0", "2010/Sep/13 17:03", "Trianco Redfyre", "Trianco", "TRO", "37/45 Mk3 CF", "", "", "obsolete", "4", "0", "0", "1", "0", "", "", "1", "2", "2", "37", "45", "", "", "70.0", "58.0", "", "42.6", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1187, "brand_name": "Trianco", "model_name": "TRO", "model_qualifier": "12/14 BF Room Sealed", "winter_efficiency_pct": 70.0, "summer_efficiency_pct": 58.0, "comparative_hot_water_efficiency_pct": 42.6, "output_kw_max": 14.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001187", "000062", "0", "2010/Sep/13 17:03", "Trianco Redfyre", "Trianco", "TRO", "12/14 BF Room Sealed", "", "", "obsolete", "4", "0", "0", "1", "0", "", "", "1", "2", "2", "12", "14", "", "", "70.0", "58.0", "", "42.6", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1188, "brand_name": "Trianco", "model_name": "TRO", "model_qualifier": "15/19 BF Room Sealed", "winter_efficiency_pct": 70.0, "summer_efficiency_pct": 58.0, "comparative_hot_water_efficiency_pct": 42.6, "output_kw_max": 19.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001188", "000062", "0", "2010/Sep/13 17:03", "Trianco Redfyre", "Trianco", "TRO", "15/19 BF Room Sealed", "", "", "obsolete", "4", "0", "0", "1", "0", "", "", "1", "2", "2", "15", "19", "", "", "70.0", "58.0", "", "42.6", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1190, "brand_name": "Trianco", "model_name": "TRO", "model_qualifier": "28/32 BF Room Sealed", "winter_efficiency_pct": 70.0, "summer_efficiency_pct": 58.0, "comparative_hot_water_efficiency_pct": 42.6, "output_kw_max": 32.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001190", "000062", "0", "2010/Sep/13 17:03", "Trianco Redfyre", "Trianco", "TRO", "28/32 BF Room Sealed", "", "", "obsolete", "4", "0", "0", "1", "0", "", "", "1", "2", "2", "28", "32", "", "", "70.0", "58.0", "", "42.6", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1191, "brand_name": "Trianco", "model_name": "TRO", "model_qualifier": "80 Combi WM C.F.", "winter_efficiency_pct": 71.0, "summer_efficiency_pct": 62.0, "comparative_hot_water_efficiency_pct": 43.2, "output_kw_max": 23.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001191", "000062", "0", "2010/Sep/13 17:03", "Trianco Redfyre", "Trianco", "TRO", "80 Combi WM C.F.", "", "", "obsolete", "4", "0", "0", "2", "0", "", "", "1", "2", "2", "23", "23", "", "", "71.0", "62.0", "", "43.2", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1192, "brand_name": "Trianco", "model_name": "TRO", "model_qualifier": "110 Combi FS C.F.", "winter_efficiency_pct": 71.0, "summer_efficiency_pct": 62.0, "comparative_hot_water_efficiency_pct": 43.2, "output_kw_max": 32.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001192", "000062", "0", "2010/Sep/13 17:03", "Trianco Redfyre", "Trianco", "TRO", "110 Combi FS C.F.", "", "", "obsolete", "4", "0", "0", "2", "0", "", "", "1", "2", "2", "32", "32", "", "", "71.0", "62.0", "", "43.2", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1193, "brand_name": "Trianco", "model_name": "Centrajet", "model_qualifier": "13/17 WM", "winter_efficiency_pct": 70.0, "summer_efficiency_pct": 58.0, "comparative_hot_water_efficiency_pct": 42.6, "output_kw_max": 17.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001193", "000062", "0", "2010/Sep/13 17:03", "Trianco Redfyre", "Trianco", "Centrajet", "13/17 WM", "", "", "obsolete", "4", "0", "0", "1", "0", "", "", "1", "2", "2", "13", "17", "", "", "70.0", "58.0", "", "42.6", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1195, "brand_name": "Trianco", "model_name": "TSB", "model_qualifier": "12/14 BF Sealed System", "winter_efficiency_pct": 70.0, "summer_efficiency_pct": 58.0, "comparative_hot_water_efficiency_pct": 42.6, "output_kw_max": 14.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001195", "000062", "0", "2010/Sep/13 17:03", "Trianco Redfyre", "Trianco", "TSB", "12/14 BF Sealed System", "", "", "obsolete", "4", "0", "0", "1", "0", "", "", "1", "2", "2", "12", "14", "", "", "70.0", "58.0", "", "42.6", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1197, "brand_name": "Trianco", "model_name": "TSB", "model_qualifier": "15/19 BF Sealed System", "winter_efficiency_pct": 70.0, "summer_efficiency_pct": 58.0, "comparative_hot_water_efficiency_pct": 42.6, "output_kw_max": 19.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001197", "000062", "0", "2010/Sep/13 17:03", "Trianco Redfyre", "Trianco", "TSB", "15/19 BF Sealed System", "", "", "obsolete", "4", "0", "0", "1", "0", "", "", "1", "2", "2", "15", "19", "", "", "70.0", "58.0", "", "42.6", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1199, "brand_name": "Trianco", "model_name": "TSB", "model_qualifier": "20/25 BF Sealed System", "winter_efficiency_pct": 70.0, "summer_efficiency_pct": 58.0, "comparative_hot_water_efficiency_pct": 42.6, "output_kw_max": 25.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001199", "000062", "0", "2010/Sep/13 17:03", "Trianco Redfyre", "Trianco", "TSB", "20/25 BF Sealed System", "", "", "obsolete", "4", "0", "0", "1", "0", "", "", "1", "2", "2", "20", "25", "", "", "70.0", "58.0", "", "42.6", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1201, "brand_name": "Trianco", "model_name": "TSV", "model_qualifier": "45", "winter_efficiency_pct": 65.0, "summer_efficiency_pct": 53.0, "comparative_hot_water_efficiency_pct": 38.9, "output_kw_max": 12.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001201", "000062", "0", "2010/Sep/13 17:03", "Trianco Redfyre", "Trianco", "TSV", "45", "", "", "obsolete", "4", "0", "0", "1", "0", "", "", "1", "1", "1", "12.3", "12.3", "", "", "65.0", "53.0", "", "38.9", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1202, "brand_name": "Trianco", "model_name": "TSV", "model_qualifier": "60", "winter_efficiency_pct": 65.0, "summer_efficiency_pct": 53.0, "comparative_hot_water_efficiency_pct": 38.9, "output_kw_max": 17.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001202", "000062", "0", "2010/Sep/13 17:03", "Trianco Redfyre", "Trianco", "TSV", "60", "", "", "obsolete", "4", "0", "0", "1", "0", "", "", "1", "1", "1", "17.6", "17.6", "", "", "65.0", "53.0", "", "38.9", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1203, "brand_name": "Trianco", "model_name": "TSV", "model_qualifier": "80", "winter_efficiency_pct": 65.0, "summer_efficiency_pct": 53.0, "comparative_hot_water_efficiency_pct": 38.9, "output_kw_max": 23.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001203", "000062", "0", "2010/Sep/13 17:03", "Trianco Redfyre", "Trianco", "TSV", "80", "", "", "obsolete", "4", "0", "0", "1", "0", "", "", "1", "1", "1", "23.4", "23.4", "", "", "65.0", "53.0", "", "38.9", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1204, "brand_name": "Trianco", "model_name": "TSO", "model_qualifier": "15/17", "winter_efficiency_pct": 65.0, "summer_efficiency_pct": 53.0, "comparative_hot_water_efficiency_pct": 38.9, "output_kw_max": 17.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001204", "000062", "0", "2010/Sep/13 17:03", "Trianco Redfyre", "Trianco", "TSO", "15/17", "", "", "obsolete", "4", "0", "0", "1", "0", "", "", "1", "2", "2", "17", "17", "", "", "65.0", "53.0", "", "38.9", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1205, "brand_name": "Trianco", "model_name": "TSO", "model_qualifier": "65/85", "winter_efficiency_pct": 65.0, "summer_efficiency_pct": 53.0, "comparative_hot_water_efficiency_pct": 38.9, "output_kw_max": 24.9, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001205", "000062", "0", "2010/Sep/13 17:03", "Trianco Redfyre", "Trianco", "TSO", "65/85", "", "", "obsolete", "4", "0", "0", "1", "0", "", "", "1", "2", "2", "24.9", "24.9", "", "", "65.0", "53.0", "", "38.9", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1206, "brand_name": "Trianco", "model_name": "TSO", "model_qualifier": "95/110", "winter_efficiency_pct": 65.0, "summer_efficiency_pct": 53.0, "comparative_hot_water_efficiency_pct": 38.9, "output_kw_max": 32.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001206", "000062", "0", "2010/Sep/13 17:03", "Trianco Redfyre", "Trianco", "TSO", "95/110", "", "", "obsolete", "4", "0", "0", "1", "0", "", "", "1", "2", "2", "32.2", "32.2", "", "", "65.0", "53.0", "", "38.9", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1223, "brand_name": "Alde", "model_name": "Slimline", "model_qualifier": "2927", "winter_efficiency_pct": 71.0, "summer_efficiency_pct": 62.0, "comparative_hot_water_efficiency_pct": 43.2, "output_kw_max": 5.8, "final_year_of_manufacture": 1991, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001223", "000067", "0", "2010/Sep/13 17:03", "Alde", "Alde", "Slimline", "2927", "4104801", "1985", "1991", "1", "1", "0", "2", "0", "", "", "1", "2", "2", "5.8", "5.8", "", "", "71.0", "62.0", "", "43.2", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1242, "brand_name": "Glotec", "model_name": "Glotec", "model_qualifier": "gt80", "winter_efficiency_pct": 91.0, "summer_efficiency_pct": 74.0, "comparative_hot_water_efficiency_pct": 53.7, "output_kw_max": 21.9, "final_year_of_manufacture": 1991, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001242", "000073", "0", "2010/Sep/13 17:03", "Glotec", "Glotec", "Glotec", "gt80", "4130501", "", "1991", "1", "0", "0", "1", "0", "", "", "2", "2", "2", "21.9", "21.9", "", "", "91.0", "74.0", "", "53.7", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0001", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1243, "brand_name": "Glow-worm", "model_name": "105-120B", "model_qualifier": "105-120B", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 35.2, "final_year_of_manufacture": 1985, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001243", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "105-120B", "105-120B", "4131556", "", "1985", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "35.2", "35.2", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1244, "brand_name": "Glow-worm", "model_name": "105-120", "model_qualifier": "105-120", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 35.2, "final_year_of_manufacture": 1985, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001244", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "105-120", "105-120", "4131555", "", "1985", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "35.2", "35.2", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1245, "brand_name": "Glow-worm", "model_name": "45-60", "model_qualifier": "45-60", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 17.6, "final_year_of_manufacture": 1985, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001245", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "45-60", "45-60", "4131549", "", "1985", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "17.6", "17.6", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1246, "brand_name": "Glow-worm", "model_name": "45-60B", "model_qualifier": "45-60B", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 17.6, "final_year_of_manufacture": 1985, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001246", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "45-60B", "45-60B", "4131550", "", "1985", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "17.6", "17.6", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1248, "brand_name": "Glow-worm", "model_name": "65-80", "model_qualifier": "65-80", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 23.5, "final_year_of_manufacture": 1985, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001248", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "65-80", "65-80", "4131551", "", "1985", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "23.5", "23.5", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1250, "brand_name": "Glow-worm", "model_name": "65-80B", "model_qualifier": "65-80B", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 23.5, "final_year_of_manufacture": 1985, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001250", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "65-80B", "65-80B", "4131558", "", "1985", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "23.5", "23.5", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1252, "brand_name": "Glow-worm", "model_name": "85-100", "model_qualifier": "85-100", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 29.3, "final_year_of_manufacture": 1985, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001252", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "85-100", "85-100", "4131553", "", "1985", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "29.3", "29.3", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1254, "brand_name": "Glow-worm", "model_name": "85-100B", "model_qualifier": "85-100B", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 29.3, "final_year_of_manufacture": 1985, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001254", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "85-100B", "85-100B", "4131560", "", "1985", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "29.3", "29.3", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1255, "brand_name": "Glow-worm", "model_name": "Camelot", "model_qualifier": "240/6", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": null, "final_year_of_manufacture": 1986, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001255", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Camelot", "240/6", "3731407", "", "1986", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "", "", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1256, "brand_name": "Glow-worm", "model_name": "Capricorn", "model_qualifier": "240/6", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": null, "final_year_of_manufacture": 1986, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001256", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Capricorn", "240/6", "3731406", "", "1986", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "", "", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1257, "brand_name": "Glow-worm", "model_name": "Capricorn", "model_qualifier": "246", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": null, "final_year_of_manufacture": 1982, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001257", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Capricorn", "246", "4431518", "", "1982", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "", "", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1259, "brand_name": "Glow-worm", "model_name": "Economy Plus", "model_qualifier": "100f", "winter_efficiency_pct": 73.0, "summer_efficiency_pct": 63.0, "comparative_hot_water_efficiency_pct": 45.9, "output_kw_max": 29.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001259", "000207", "0", "2015/Jul/21 14:15", "Glow-worm", "Glow-worm", "Economy Plus", "100f", "", "", "obsolete", "1", "0", "0", "1", "0", "", "", "1", "2", "2", "29.3", "29.3", "", "", "73.0", "63.0", "", "45.9", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1277, "brand_name": "Glow-worm", "model_name": "Fuelsaver", "model_qualifier": "100F", "winter_efficiency_pct": 73.0, "summer_efficiency_pct": 63.0, "comparative_hot_water_efficiency_pct": 45.9, "output_kw_max": 29.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001277", "000207", "0", "2015/Jul/21 14:15", "Glow-worm", "Glow-worm", "Fuelsaver", "100F", "4131332", "", "obsolete", "1", "0", "0", "1", "0", "", "", "1", "2", "2", "29.3", "29.3", "", "", "73.0", "63.0", "", "45.9", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1278, "brand_name": "Glow-worm", "model_name": "Fuelsaver", "model_qualifier": "25-30", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 8.8, "final_year_of_manufacture": 1984, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001278", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Fuelsaver", "25-30", "4131580", "", "1984", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "8.8", "8.8", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1279, "brand_name": "Glow-worm", "model_name": "Fuelsaver", "model_qualifier": "25-30B", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 8.79, "final_year_of_manufacture": 1984, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001279", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Fuelsaver", "25-30B", "4131579", "", "1984", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "8.79", "8.79", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1280, "brand_name": "Glow-worm", "model_name": "Fuelsaver", "model_qualifier": "30-40", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 11.7, "final_year_of_manufacture": 1984, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001280", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Fuelsaver", "30-40", "4131582", "", "1984", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "11.7", "11.7", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1281, "brand_name": "Glow-worm", "model_name": "Fuelsaver", "model_qualifier": "30-40B", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 11.72, "final_year_of_manufacture": 1983, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001281", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Fuelsaver", "30-40B", "4131581", "", "1983", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "11.72", "11.72", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1282, "brand_name": "Glow-worm", "model_name": "Fuelsaver", "model_qualifier": "30bmk2", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 8.79, "final_year_of_manufacture": 1988, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001282", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Fuelsaver", "30bmk2", "4131304", "", "1988", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "8.79", "8.79", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1283, "brand_name": "Glow-worm", "model_name": "Fuelsaver", "model_qualifier": "30brmk2", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 8.79, "final_year_of_manufacture": 1991, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001283", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Fuelsaver", "30brmk2", "4131372", "", "1991", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "8.79", "8.79", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1284, "brand_name": "Glow-worm", "model_name": "Fuelsaver", "model_qualifier": "30mk2", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 8.79, "final_year_of_manufacture": 1988, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001284", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Fuelsaver", "30mk2", "4131318", "", "1988", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "8.79", "8.79", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1285, "brand_name": "Glow-worm", "model_name": "Fuelsaver", "model_qualifier": "35f", "winter_efficiency_pct": 69.0, "summer_efficiency_pct": 59.0, "comparative_hot_water_efficiency_pct": 43.0, "output_kw_max": 10.26, "final_year_of_manufacture": 1991, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001285", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Fuelsaver", "35f", "4131309", "", "1991", "1", "0", "0", "1", "0", "", "", "1", "2", "2", "10.26", "10.26", "", "", "69.0", "59.0", "", "43.0", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1286, "brand_name": "Glow-worm", "model_name": "Fuelsaver", "model_qualifier": "40-50", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 14.7, "final_year_of_manufacture": 1984, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001286", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Fuelsaver", "40-50", "4131584", "", "1984", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "14.7", "14.7", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1287, "brand_name": "Glow-worm", "model_name": "Fuelsaver", "model_qualifier": "40-50b", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 14.65, "final_year_of_manufacture": 1983, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001287", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Fuelsaver", "40-50b", "4131583", "", "1983", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "14.65", "14.65", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1288, "brand_name": "Glow-worm", "model_name": "Fuelsaver", "model_qualifier": "40bmk2", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 11.72, "final_year_of_manufacture": 1988, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001288", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Fuelsaver", "40bmk2", "4131596", "", "1988", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "11.72", "11.72", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1289, "brand_name": "Glow-worm", "model_name": "Fuelsaver", "model_qualifier": "40brmk2", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 11.72, "final_year_of_manufacture": 1991, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001289", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Fuelsaver", "40brmk2", "4131373", "", "1991", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "11.72", "11.72", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1290, "brand_name": "Glow-worm", "model_name": "Fuelsaver", "model_qualifier": "40mk2", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 11.7, "final_year_of_manufacture": 1988, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001290", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Fuelsaver", "40mk2", "4131319", "", "1988", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "11.7", "11.7", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1291, "brand_name": "Glow-worm", "model_name": "Fuelsaver", "model_qualifier": "45f", "winter_efficiency_pct": 69.0, "summer_efficiency_pct": 59.0, "comparative_hot_water_efficiency_pct": 43.0, "output_kw_max": 13.19, "final_year_of_manufacture": 1991, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001291", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Fuelsaver", "45f", "4131335", "", "1991", "1", "0", "0", "1", "0", "", "", "1", "2", "2", "13.19", "13.19", "", "", "69.0", "59.0", "", "43.0", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1292, "brand_name": "Glow-worm", "model_name": "Fuelsaver", "model_qualifier": "50bmk2", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 14.65, "final_year_of_manufacture": 1988, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001292", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Fuelsaver", "50bmk2", "4131595", "", "1988", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "14.65", "14.65", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1293, "brand_name": "Glow-worm", "model_name": "Fuelsaver", "model_qualifier": "50brmk2", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 14.65, "final_year_of_manufacture": 1991, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001293", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Fuelsaver", "50brmk2", "4131374", "", "1991", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "14.65", "14.65", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1294, "brand_name": "Glow-worm", "model_name": "Fuelsaver", "model_qualifier": "50mk2", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 14.65, "final_year_of_manufacture": 1988, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001294", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Fuelsaver", "50mk2", "4131320", "", "1988", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "14.65", "14.65", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1295, "brand_name": "Glow-worm", "model_name": "Fuelsaver", "model_qualifier": "55-60b", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 17.6, "final_year_of_manufacture": 1984, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001295", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Fuelsaver", "55-60b", "4131585", "", "1984", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "17.6", "17.6", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1296, "brand_name": "Glow-worm", "model_name": "Fuelsaver", "model_qualifier": "55f", "winter_efficiency_pct": 69.0, "summer_efficiency_pct": 59.0, "comparative_hot_water_efficiency_pct": 43.0, "output_kw_max": 16.12, "final_year_of_manufacture": 1991, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001296", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Fuelsaver", "55f", "4131306", "", "1991", "1", "0", "0", "1", "0", "", "", "1", "2", "2", "16.12", "16.12", "", "", "69.0", "59.0", "", "43.0", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1297, "brand_name": "Glow-worm", "model_name": "Fuelsaver", "model_qualifier": "60-70b", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 20.5, "final_year_of_manufacture": 1984, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001297", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Fuelsaver", "60-70b", "4131587", "", "1984", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "20.5", "20.5", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1298, "brand_name": "Glow-worm", "model_name": "Fuelsaver", "model_qualifier": "60bmk2", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 17.58, "final_year_of_manufacture": 1988, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001298", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Fuelsaver", "60bmk2", "4131310", "", "1988", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "17.58", "17.58", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1299, "brand_name": "Glow-worm", "model_name": "Fuelsaver", "model_qualifier": "60brmk2", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 17.59, "final_year_of_manufacture": 1991, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001299", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Fuelsaver", "60brmk2", "4131375", "", "1991", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "17.59", "17.59", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1300, "brand_name": "Glow-worm", "model_name": "Fuelsaver", "model_qualifier": "60mk2", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 17.59, "final_year_of_manufacture": 1988, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001300", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Fuelsaver", "60mk2", "4131330", "", "1988", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "17.59", "17.59", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1301, "brand_name": "Glow-worm", "model_name": "Fuelsaver", "model_qualifier": "65f", "winter_efficiency_pct": 69.0, "summer_efficiency_pct": 59.0, "comparative_hot_water_efficiency_pct": 43.0, "output_kw_max": 19.1, "final_year_of_manufacture": 1991, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001301", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Fuelsaver", "65f", "4131333", "", "1991", "1", "0", "0", "1", "0", "", "", "1", "2", "2", "19.1", "19.1", "", "", "69.0", "59.0", "", "43.0", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1302, "brand_name": "Glow-worm", "model_name": "Fuelsaver", "model_qualifier": "75bmk2", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 22.0, "final_year_of_manufacture": 1988, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001302", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Fuelsaver", "75bmk2", "4131311", "", "1988", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "22", "22", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1303, "brand_name": "Glow-worm", "model_name": "Fuelsaver", "model_qualifier": "75brmk2", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 22.0, "final_year_of_manufacture": 1991, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001303", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Fuelsaver", "75brmk2", "4131376", "", "1991", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "22", "22", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1304, "brand_name": "Glow-worm", "model_name": "Fuelsaver", "model_qualifier": "75mk2", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 21.4, "final_year_of_manufacture": 1988, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001304", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Fuelsaver", "75mk2", "4131331", "", "1988", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "21.4", "21.4", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1305, "brand_name": "Glow-worm", "model_name": "Fuelsaver", "model_qualifier": "80f", "winter_efficiency_pct": 69.0, "summer_efficiency_pct": 59.0, "comparative_hot_water_efficiency_pct": 43.0, "output_kw_max": 23.4, "final_year_of_manufacture": 1991, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001305", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Fuelsaver", "80f", "4131323", "", "1991", "1", "0", "0", "1", "0", "", "", "1", "2", "2", "23.4", "23.4", "", "", "69.0", "59.0", "", "43.0", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1311, "brand_name": "Glow-worm", "model_name": "Galaxie", "model_qualifier": "240/6", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": null, "final_year_of_manufacture": 1986, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001311", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Galaxie", "240/6", "3731405", "", "1986", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "", "", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1313, "brand_name": "Glow-worm", "model_name": "Galaxie", "model_qualifier": "246", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": null, "final_year_of_manufacture": 1982, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001313", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Galaxie", "246", "4431516", "", "1982", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "", "", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1314, "brand_name": "Glow-worm", "model_name": "240", "model_qualifier": "", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": null, "final_year_of_manufacture": 1986, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001314", "000207", "0", "2013/Jan/30 14:48", "Glow-worm", "Glow-worm", "240", "", "4431526", "", "1986", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "", "", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1315, "brand_name": "Glow-worm", "model_name": "246", "model_qualifier": "", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": null, "final_year_of_manufacture": 1986, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001315", "000207", "0", "2013/Jan/30 14:48", "Glow-worm", "Glow-worm", "246", "", "4431525", "", "1986", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "", "", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1316, "brand_name": "Glow-worm", "model_name": "45", "model_qualifier": "", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": null, "final_year_of_manufacture": 1996, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001316", "000207", "0", "2013/Jan/30 14:48", "Glow-worm", "Glow-worm", "45", "", "4431527", "", "1996", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "", "", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1317, "brand_name": "Glow-worm", "model_name": "45F", "model_qualifier": "", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": null, "final_year_of_manufacture": 1999, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001317", "000207", "0", "2013/Jan/30 14:49", "Glow-worm", "Glow-worm", "45F", "", "4431529", "", "1999", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "", "", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1318, "brand_name": "Glow-worm", "model_name": "45FR", "model_qualifier": "", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": null, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001318", "000207", "0", "2013/Jan/30 14:49", "Glow-worm", "Glow-worm", "45FR", "", "4431531", "", "obsolete", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "", "", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1319, "brand_name": "Glow-worm", "model_name": "56", "model_qualifier": "", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": null, "final_year_of_manufacture": 1996, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001319", "000207", "0", "2013/Jan/30 14:49", "Glow-worm", "Glow-worm", "56", "", "4431528", "", "1996", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "", "", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1320, "brand_name": "Glow-worm", "model_name": "56F", "model_qualifier": "", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": null, "final_year_of_manufacture": 1999, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001320", "000207", "0", "2013/Jan/30 14:49", "Glow-worm", "Glow-worm", "56F", "", "4431530", "", "1999", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "", "", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1321, "brand_name": "Glow-worm", "model_name": "56FR", "model_qualifier": "", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": null, "final_year_of_manufacture": 1999, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001321", "000207", "0", "2013/Jan/30 14:49", "Glow-worm", "Glow-worm", "56FR", "", "4431532", "", "1999", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "", "", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1329, "brand_name": "Glow-worm", "model_name": "Hideaway", "model_qualifier": "60BL", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 17.6, "final_year_of_manufacture": 1985, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001329", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Hideaway", "60BL", "4131312", "", "1985", "1", "1", "0", "1", "0", "", "", "1", "2", "1", "17.6", "17.6", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1330, "brand_name": "Glow-worm", "model_name": "Hideaway", "model_qualifier": "60L", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 17.6, "final_year_of_manufacture": 1995, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001330", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Hideaway", "60L", "4131313", "", "1995", "1", "1", "0", "1", "0", "", "", "1", "1", "1", "17.6", "17.6", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1332, "brand_name": "Glow-worm", "model_name": "Hideaway", "model_qualifier": "70of", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 20.52, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001332", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Hideaway", "70of", "4131382", "1984", "obsolete", "1", "1", "0", "1", "0", "", "", "1", "1", "1", "20.52", "20.52", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1333, "brand_name": "Glow-worm", "model_name": "Hideaway", "model_qualifier": "80BL", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 23.45, "final_year_of_manufacture": 1994, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001333", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Hideaway", "80BL", "4131324", "", "1994", "1", "1", "0", "1", "0", "", "", "1", "2", "1", "23.45", "23.45", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1334, "brand_name": "Glow-worm", "model_name": "Hideaway", "model_qualifier": "80L", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 23.45, "final_year_of_manufacture": 1994, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001334", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Hideaway", "80L", "4131325", "", "1994", "1", "1", "0", "1", "0", "", "", "1", "1", "1", "23.45", "23.45", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1336, "brand_name": "Glow-worm", "model_name": "Hideaway", "model_qualifier": "90of", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 26.38, "final_year_of_manufacture": 1999, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001336", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Hideaway", "90of", "4131384", "1984", "1999", "1", "1", "0", "1", "0", "", "", "1", "1", "1", "26.38", "26.38", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1337, "brand_name": "Glow-worm", "model_name": "Majorca", "model_qualifier": "240/6", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": null, "final_year_of_manufacture": 1986, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001337", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Majorca", "240/6", "3731402", "", "1986", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "", "", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1338, "brand_name": "Glow-worm", "model_name": "Majorca", "model_qualifier": "246", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": null, "final_year_of_manufacture": 1982, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001338", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Majorca", "246", "", "", "1982", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "", "", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1339, "brand_name": "Glow-worm", "model_name": "Majorca", "model_qualifier": "340/6", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": null, "final_year_of_manufacture": 1986, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001339", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Majorca", "340/6", "3731403", "", "1986", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "", "", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1340, "brand_name": "Glow-worm", "model_name": "Majorca", "model_qualifier": "340/6auto", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": null, "final_year_of_manufacture": 1986, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001340", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Majorca", "340/6auto", "3731404", "", "1986", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "", "", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1341, "brand_name": "Glow-worm", "model_name": "Majorca", "model_qualifier": "346", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": null, "final_year_of_manufacture": 1982, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001341", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Majorca", "346", "", "", "1982", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "", "", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1354, "brand_name": "Glow-worm", "model_name": "Royale", "model_qualifier": "240/6", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": null, "final_year_of_manufacture": 1986, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001354", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Royale", "240/6", "3731401", "", "1986", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "", "", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1355, "brand_name": "Glow-worm", "model_name": "Royale", "model_qualifier": "246", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": null, "final_year_of_manufacture": 1982, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001355", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Royale", "246", "4431523", "", "1982", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "", "", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1356, "brand_name": "Glow-worm", "model_name": "Spacesaver", "model_qualifier": "20-30f", "winter_efficiency_pct": 69.0, "summer_efficiency_pct": 59.0, "comparative_hot_water_efficiency_pct": 43.0, "output_kw_max": 8.79, "final_year_of_manufacture": 1989, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001356", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Spacesaver", "20-30f", "4131371", "", "1989", "1", "0", "0", "1", "0", "", "", "1", "2", "2", "8.79", "8.79", "", "", "69.0", "59.0", "", "43.0", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1357, "brand_name": "Glow-worm", "model_name": "Spacesaver", "model_qualifier": "20-30rf", "winter_efficiency_pct": 69.0, "summer_efficiency_pct": 59.0, "comparative_hot_water_efficiency_pct": 43.0, "output_kw_max": 8.79, "final_year_of_manufacture": 1989, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001357", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Spacesaver", "20-30rf", "4131386", "", "1989", "1", "2", "0", "1", "0", "", "", "1", "2", "2", "8.79", "8.79", "", "", "69.0", "59.0", "", "43.0", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1358, "brand_name": "Glow-worm", "model_name": "Spacesaver", "model_qualifier": "20-30rfs", "winter_efficiency_pct": 69.0, "summer_efficiency_pct": 59.0, "comparative_hot_water_efficiency_pct": 43.0, "output_kw_max": 8.79, "final_year_of_manufacture": 1989, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001358", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Spacesaver", "20-30rfs", "4131391", "", "1989", "1", "2", "0", "1", "0", "", "", "1", "2", "2", "8.79", "8.79", "", "", "69.0", "59.0", "", "43.0", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1359, "brand_name": "Glow-worm", "model_name": "Spacesaver", "model_qualifier": "22-30b", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 8.79, "final_year_of_manufacture": 1983, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001359", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Spacesaver", "22-30b", "4131569", "", "1983", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "8.79", "8.79", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1360, "brand_name": "Glow-worm", "model_name": "Spacesaver", "model_qualifier": "22-30f", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 8.79, "final_year_of_manufacture": 1984, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001360", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Spacesaver", "22-30f", "4131570", "", "1984", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "8.79", "8.79", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1361, "brand_name": "Glow-worm", "model_name": "Spacesaver", "model_qualifier": "30-40f", "winter_efficiency_pct": 69.0, "summer_efficiency_pct": 59.0, "comparative_hot_water_efficiency_pct": 43.0, "output_kw_max": 11.72, "final_year_of_manufacture": 1989, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001361", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Spacesaver", "30-40f", "4131368", "", "1989", "1", "0", "0", "1", "0", "", "", "1", "2", "2", "11.72", "11.72", "", "", "69.0", "59.0", "", "43.0", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1362, "brand_name": "Glow-worm", "model_name": "Spacesaver", "model_qualifier": "30-40rf", "winter_efficiency_pct": 69.0, "summer_efficiency_pct": 59.0, "comparative_hot_water_efficiency_pct": 43.0, "output_kw_max": 11.72, "final_year_of_manufacture": 1992, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001362", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Spacesaver", "30-40rf", "4131387", "", "1992", "1", "2", "0", "1", "0", "", "", "1", "2", "2", "11.72", "11.72", "", "", "69.0", "59.0", "", "43.0", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1363, "brand_name": "Glow-worm", "model_name": "Spacesaver", "model_qualifier": "30-40rfs", "winter_efficiency_pct": 69.0, "summer_efficiency_pct": 59.0, "comparative_hot_water_efficiency_pct": 43.0, "output_kw_max": 11.72, "final_year_of_manufacture": 1992, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001363", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Spacesaver", "30-40rfs", "4131392", "", "1992", "1", "2", "0", "1", "0", "", "", "1", "2", "2", "11.72", "11.72", "", "", "69.0", "59.0", "", "43.0", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1364, "brand_name": "Glow-worm", "model_name": "Spacesaver", "model_qualifier": "30bmk2", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 8.79, "final_year_of_manufacture": 1988, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001364", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Spacesaver", "30bmk2", "4131594", "", "1988", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "8.79", "8.79", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1365, "brand_name": "Glow-worm", "model_name": "Spacesaver", "model_qualifier": "30brmk2", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 8.79, "final_year_of_manufacture": 1988, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001365", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Spacesaver", "30brmk2", "4131353", "", "1988", "1", "2", "0", "1", "0", "", "", "1", "2", "1", "8.79", "8.79", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1366, "brand_name": "Glow-worm", "model_name": "Spacesaver", "model_qualifier": "30mk2", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 8.79, "final_year_of_manufacture": 1988, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001366", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Spacesaver", "30mk2", "4131307", "", "1988", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "8.79", "8.79", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1367, "brand_name": "Glow-worm", "model_name": "Spacesaver", "model_qualifier": "30rmk2", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 8.79, "final_year_of_manufacture": 1993, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001367", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Spacesaver", "30rmk2", "4131358", "", "1993", "1", "2", "0", "1", "0", "", "", "1", "1", "1", "8.79", "8.79", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1368, "brand_name": "Glow-worm", "model_name": "Spacesaver", "model_qualifier": "38bf", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 11.1, "final_year_of_manufacture": 1983, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001368", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Spacesaver", "38bf", "4131531", "", "1983", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "11.1", "11.1", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1369, "brand_name": "Glow-worm", "model_name": "Spacesaver", "model_qualifier": "38", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 11.14, "final_year_of_manufacture": 1984, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001369", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Spacesaver", "38", "4131544", "", "1984", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "11.14", "11.14", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1370, "brand_name": "Glow-worm", "model_name": "Spacesaver", "model_qualifier": "50f", "winter_efficiency_pct": 69.0, "summer_efficiency_pct": 59.0, "comparative_hot_water_efficiency_pct": 43.0, "output_kw_max": 14.65, "final_year_of_manufacture": 1989, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001370", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Spacesaver", "50f", "4131370", "", "1989", "1", "0", "0", "1", "0", "", "", "1", "2", "2", "14.65", "14.65", "", "", "69.0", "59.0", "", "43.0", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1371, "brand_name": "Glow-worm", "model_name": "Spacesaver", "model_qualifier": "40-50rf", "winter_efficiency_pct": 69.0, "summer_efficiency_pct": 59.0, "comparative_hot_water_efficiency_pct": 43.0, "output_kw_max": 14.65, "final_year_of_manufacture": 1989, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001371", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Spacesaver", "40-50rf", "4131388", "", "1989", "1", "2", "0", "1", "0", "", "", "1", "2", "2", "14.65", "14.65", "", "", "69.0", "59.0", "", "43.0", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1372, "brand_name": "Glow-worm", "model_name": "Spacesaver", "model_qualifier": "40-50rfs", "winter_efficiency_pct": 69.0, "summer_efficiency_pct": 59.0, "comparative_hot_water_efficiency_pct": 43.0, "output_kw_max": 14.65, "final_year_of_manufacture": 1992, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001372", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Spacesaver", "40-50rfs", "4131393", "", "1992", "1", "1", "0", "1", "0", "", "", "1", "2", "2", "14.65", "14.65", "", "", "69.0", "59.0", "", "43.0", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1373, "brand_name": "Glow-worm", "model_name": "Spacesaver", "model_qualifier": "40bmk2", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 11.72, "final_year_of_manufacture": 1988, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001373", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Spacesaver", "40bmk2", "4131588", "", "1988", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "11.72", "11.72", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1374, "brand_name": "Glow-worm", "model_name": "Spacesaver", "model_qualifier": "40brmk2", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 11.72, "final_year_of_manufacture": 1993, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001374", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Spacesaver", "40brmk2", "4131354", "", "1993", "1", "2", "0", "1", "0", "", "", "1", "2", "1", "11.72", "11.72", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1375, "brand_name": "Glow-worm", "model_name": "Spacesaver", "model_qualifier": "40f", "winter_efficiency_pct": 69.0, "summer_efficiency_pct": 59.0, "comparative_hot_water_efficiency_pct": 43.0, "output_kw_max": 11.72, "final_year_of_manufacture": 1988, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001375", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Spacesaver", "40f", "4131337", "", "1988", "1", "0", "0", "1", "0", "", "", "1", "2", "2", "11.72", "11.72", "", "", "69.0", "59.0", "", "43.0", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1376, "brand_name": "Glow-worm", "model_name": "Spacesaver", "model_qualifier": "40mk2", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 11.72, "final_year_of_manufacture": 1988, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001376", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Spacesaver", "40mk2", "4131589", "", "1988", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "11.72", "11.72", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1377, "brand_name": "Glow-worm", "model_name": "Spacesaver", "model_qualifier": "40rmk2", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 11.72, "final_year_of_manufacture": 1992, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001377", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Spacesaver", "40rmk2", "4131359", "", "1992", "1", "2", "0", "1", "0", "", "", "1", "1", "1", "11.72", "11.72", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1378, "brand_name": "Glow-worm", "model_name": "Spacesaver", "model_qualifier": "45-60b", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 17.59, "final_year_of_manufacture": 1984, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001378", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Spacesaver", "45-60b", "4131564", "", "1984", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "17.59", "17.59", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1379, "brand_name": "Glow-worm", "model_name": "Spacesaver", "model_qualifier": "45-60", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 17.59, "final_year_of_manufacture": 1984, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001379", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Spacesaver", "45-60", "4131563", "", "1984", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "17.59", "17.59", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1381, "brand_name": "Glow-worm", "model_name": "Spacesaver", "model_qualifier": "50-60rf", "winter_efficiency_pct": 69.0, "summer_efficiency_pct": 59.0, "comparative_hot_water_efficiency_pct": 43.0, "output_kw_max": 17.59, "final_year_of_manufacture": 1992, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001381", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Spacesaver", "50-60rf", "4131389", "", "1992", "1", "2", "0", "1", "0", "", "", "1", "2", "2", "17.59", "17.59", "", "", "69.0", "59.0", "", "43.0", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1382, "brand_name": "Glow-worm", "model_name": "Spacesaver", "model_qualifier": "50-60rfs", "winter_efficiency_pct": 69.0, "summer_efficiency_pct": 59.0, "comparative_hot_water_efficiency_pct": 43.0, "output_kw_max": 17.59, "final_year_of_manufacture": 1992, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001382", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Spacesaver", "50-60rfs", "4131394", "", "1992", "1", "2", "0", "1", "0", "", "", "1", "2", "2", "17.59", "17.59", "", "", "69.0", "59.0", "", "43.0", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1383, "brand_name": "Glow-worm", "model_name": "Spacesaver", "model_qualifier": "50bf", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 14.6, "final_year_of_manufacture": 1982, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001383", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Spacesaver", "50bf", "4131527", "", "1982", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "14.6", "14.6", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1384, "brand_name": "Glow-worm", "model_name": "Spacesaver", "model_qualifier": "50bmk2", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 14.65, "final_year_of_manufacture": 1988, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001384", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Spacesaver", "50bmk2", "4131571", "", "1988", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "14.65", "14.65", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1386, "brand_name": "Glow-worm", "model_name": "Spacesaver", "model_qualifier": "50mk2", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 14.65, "final_year_of_manufacture": 1988, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001386", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Spacesaver", "50mk2", "4131303", "", "1988", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "14.65", "14.65", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1387, "brand_name": "Glow-worm", "model_name": "Spacesaver", "model_qualifier": "50rmk2", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 14.65, "final_year_of_manufacture": 1992, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001387", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Spacesaver", "50rmk2", "4131360", "", "1992", "1", "2", "0", "1", "0", "", "", "1", "1", "1", "14.65", "14.65", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1388, "brand_name": "Glow-worm", "model_name": "Spacesaver", "model_qualifier": "52", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 15.24, "final_year_of_manufacture": 1984, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001388", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Spacesaver", "52", "4131545", "", "1984", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "15.24", "15.24", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1389, "brand_name": "Glow-worm", "model_name": "Spacesaver", "model_qualifier": "60bmk2", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 17.59, "final_year_of_manufacture": 1988, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001389", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Spacesaver", "60bmk2", "4131302", "", "1988", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "17.59", "17.59", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1390, "brand_name": "Glow-worm", "model_name": "Spacesaver", "model_qualifier": "60brmk2", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 17.59, "final_year_of_manufacture": 1992, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001390", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Spacesaver", "60brmk2", "4131356", "", "1992", "1", "2", "0", "1", "0", "", "", "1", "2", "1", "17.59", "17.59", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1391, "brand_name": "Glow-worm", "model_name": "Spacesaver", "model_qualifier": "60f", "winter_efficiency_pct": 69.0, "summer_efficiency_pct": 59.0, "comparative_hot_water_efficiency_pct": 43.0, "output_kw_max": 17.59, "final_year_of_manufacture": 1988, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001391", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Spacesaver", "60f", "4131336", "", "1988", "1", "0", "0", "1", "0", "", "", "1", "2", "2", "17.59", "17.59", "", "", "69.0", "59.0", "", "43.0", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1392, "brand_name": "Glow-worm", "model_name": "Spacesaver", "model_qualifier": "60mk2", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 17.59, "final_year_of_manufacture": 1988, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001392", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Spacesaver", "60mk2", "4131308", "", "1988", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "17.59", "17.59", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1393, "brand_name": "Glow-worm", "model_name": "Spacesaver", "model_qualifier": "60rmk2", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 17.59, "final_year_of_manufacture": 1993, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001393", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Spacesaver", "60rmk2", "4131361", "", "1993", "1", "2", "0", "1", "0", "", "", "1", "1", "1", "17.59", "17.59", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1394, "brand_name": "Glow-worm", "model_name": "Spacesaver", "model_qualifier": "65-75f", "winter_efficiency_pct": 69.0, "summer_efficiency_pct": 59.0, "comparative_hot_water_efficiency_pct": 43.0, "output_kw_max": 21.98, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001394", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Spacesaver", "65-75f", "4131338", "", "obsolete", "1", "2", "0", "1", "0", "", "", "1", "2", "2", "21.98", "21.98", "", "", "69.0", "59.0", "", "43.0", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1395, "brand_name": "Glow-worm", "model_name": "Spacesaver", "model_qualifier": "75bf", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 21.98, "final_year_of_manufacture": 1984, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001395", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Spacesaver", "75bf", "4131532", "", "1984", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "21.98", "21.98", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1396, "brand_name": "Glow-worm", "model_name": "Spacesaver", "model_qualifier": "75", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 21.98, "final_year_of_manufacture": 1992, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001396", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Spacesaver", "75", "4131546", "", "1992", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "21.98", "21.98", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1397, "brand_name": "Glow-worm", "model_name": "Spacesaver", "model_qualifier": "80bmk2", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 23.45, "final_year_of_manufacture": 1988, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001397", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Spacesaver", "80bmk2", "4131305", "", "1988", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "23.45", "23.45", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1398, "brand_name": "Glow-worm", "model_name": "Spacesaver", "model_qualifier": "80brmk2", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 23.45, "final_year_of_manufacture": 1992, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001398", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Spacesaver", "80brmk2", "4131357", "", "1992", "1", "2", "0", "1", "0", "", "", "1", "2", "1", "23.45", "23.45", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1399, "brand_name": "Glow-worm", "model_name": "Suburban", "model_qualifier": "Suburban", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": null, "final_year_of_manufacture": 1974, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001399", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Suburban", "Suburban", "4431504", "", "1974", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "", "", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1400, "brand_name": "Glow-worm", "model_name": "Super", "model_qualifier": "30", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 8.79, "final_year_of_manufacture": 1985, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001400", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Super", "30", "4131577", "", "1985", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "8.79", "8.79", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1401, "brand_name": "Glow-worm", "model_name": "Super", "model_qualifier": "30b", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 8.79, "final_year_of_manufacture": 1984, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001401", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Super", "30b", "4131578", "", "1984", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "8.79", "8.79", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1402, "brand_name": "Glow-worm", "model_name": "Super", "model_qualifier": "40", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 11.7, "final_year_of_manufacture": 1984, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001402", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Super", "40", "4131565", "", "1984", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "11.7", "11.7", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1403, "brand_name": "Glow-worm", "model_name": "Super", "model_qualifier": "40b", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 11.7, "final_year_of_manufacture": 1984, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001403", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Super", "40b", "4131566", "", "1984", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "11.7", "11.7", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1404, "brand_name": "Glow-worm", "model_name": "Super", "model_qualifier": "52", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 15.2, "final_year_of_manufacture": 1985, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001404", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Super", "52", "4131547", "", "1985", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "15.2", "15.2", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1405, "brand_name": "Glow-worm", "model_name": "Super", "model_qualifier": "52b", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 15.2, "final_year_of_manufacture": 1985, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001405", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Super", "52b", "4131548", "", "1985", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "15.2", "15.2", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1422, "brand_name": "Glow-worm", "model_name": "Ultimate", "model_qualifier": "80bf", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 23.45, "final_year_of_manufacture": 1998, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001422", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Ultimate", "80bf", "4131955", "", "1998", "1", "2", "0", "1", "0", "", "", "1", "2", "1", "23.45", "23.45", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1424, "brand_name": "Glow-worm", "model_name": "Swiftflow", "model_qualifier": "75", "winter_efficiency_pct": 71.0, "summer_efficiency_pct": 62.0, "comparative_hot_water_efficiency_pct": 43.2, "output_kw_max": 16.1, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001424", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Swiftflow", "75", "", "", "obsolete", "1", "0", "0", "2", "0", "", "", "1", "2", "2", "16.1", "16.1", "", "", "71.0", "62.0", "", "43.2", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1425, "brand_name": "Glow-worm", "model_name": "Swiftflow", "model_qualifier": "80", "winter_efficiency_pct": 71.0, "summer_efficiency_pct": 62.0, "comparative_hot_water_efficiency_pct": 43.2, "output_kw_max": 17.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001425", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Swiftflow", "80", "", "", "obsolete", "1", "0", "0", "2", "0", "", "", "1", "2", "2", "17.6", "17.6", "", "", "71.0", "62.0", "", "43.2", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1426, "brand_name": "Glow-worm", "model_name": "Swiftflow", "model_qualifier": "100", "winter_efficiency_pct": 71.0, "summer_efficiency_pct": 62.0, "comparative_hot_water_efficiency_pct": 43.2, "output_kw_max": 17.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001426", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Swiftflow", "100", "", "", "obsolete", "1", "0", "0", "2", "0", "", "", "1", "2", "2", "17.6", "17.6", "", "", "71.0", "62.0", "", "43.2", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1434, "brand_name": "Glow-worm", "model_name": "Fuelsaver Economy Plus", "model_qualifier": "24B", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 7.03, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001434", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Fuelsaver Economy Plus", "24B", "", "", "obsolete", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "7.03", "7.03", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1435, "brand_name": "Glow-worm", "model_name": "Fuelsaver Economy Plus", "model_qualifier": "30B", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 8.79, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001435", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Fuelsaver Economy Plus", "30B", "", "", "obsolete", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "8.79", "8.79", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1436, "brand_name": "Glow-worm", "model_name": "Fuelsaver Economy Plus", "model_qualifier": "40B", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 11.72, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001436", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Fuelsaver Economy Plus", "40B", "", "", "obsolete", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "11.72", "11.72", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1438, "brand_name": "Glow-worm", "model_name": "Fuelsaver Economy Plus", "model_qualifier": "60B", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 17.59, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001438", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Fuelsaver Economy Plus", "60B", "", "", "obsolete", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "17.59", "17.59", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1439, "brand_name": "Glow-worm", "model_name": "Fuelsaver Economy Plus", "model_qualifier": "24F", "winter_efficiency_pct": 69.0, "summer_efficiency_pct": 59.0, "comparative_hot_water_efficiency_pct": 43.0, "output_kw_max": 7.03, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001439", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Fuelsaver Economy Plus", "24F", "", "", "obsolete", "1", "0", "0", "1", "0", "", "", "1", "2", "2", "7.03", "7.03", "", "", "69.0", "59.0", "", "43.0", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1440, "brand_name": "Glow-worm", "model_name": "Fuelsaver Economy Plus", "model_qualifier": "30F", "winter_efficiency_pct": 69.0, "summer_efficiency_pct": 59.0, "comparative_hot_water_efficiency_pct": 43.0, "output_kw_max": 8.79, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001440", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Fuelsaver Economy Plus", "30F", "", "", "obsolete", "1", "0", "0", "1", "0", "", "", "1", "2", "2", "8.79", "8.79", "", "", "69.0", "59.0", "", "43.0", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1441, "brand_name": "Glow-worm", "model_name": "Fuelsaver Economy Plus", "model_qualifier": "40F", "winter_efficiency_pct": 69.0, "summer_efficiency_pct": 59.0, "comparative_hot_water_efficiency_pct": 43.0, "output_kw_max": 11.72, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001441", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Fuelsaver Economy Plus", "40F", "", "", "obsolete", "1", "0", "0", "1", "0", "", "", "1", "2", "2", "11.72", "11.72", "", "", "69.0", "59.0", "", "43.0", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1442, "brand_name": "Glow-worm", "model_name": "Fuelsaver Economy Plus", "model_qualifier": "50F", "winter_efficiency_pct": 69.0, "summer_efficiency_pct": 59.0, "comparative_hot_water_efficiency_pct": 43.0, "output_kw_max": 14.65, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001442", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Fuelsaver Economy Plus", "50F", "", "", "obsolete", "1", "0", "0", "1", "0", "", "", "1", "2", "2", "14.65", "14.65", "", "", "69.0", "59.0", "", "43.0", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1443, "brand_name": "Glow-worm", "model_name": "Fuelsaver Economy Plus", "model_qualifier": "60F", "winter_efficiency_pct": 69.0, "summer_efficiency_pct": 59.0, "comparative_hot_water_efficiency_pct": 43.0, "output_kw_max": 17.58, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001443", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Fuelsaver Economy Plus", "60F", "", "", "obsolete", "1", "0", "0", "1", "0", "", "", "1", "2", "2", "17.58", "17.58", "", "", "69.0", "59.0", "", "43.0", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1444, "brand_name": "Glow-worm", "model_name": "Fuelsaver Economy Plus", "model_qualifier": "80F", "winter_efficiency_pct": 69.0, "summer_efficiency_pct": 59.0, "comparative_hot_water_efficiency_pct": 43.0, "output_kw_max": 23.45, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001444", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Fuelsaver Economy Plus", "80F", "", "", "obsolete", "1", "0", "0", "1", "0", "", "", "1", "2", "2", "23.45", "23.45", "", "", "69.0", "59.0", "", "43.0", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1446, "brand_name": "Glow-worm", "model_name": "Fuelsaver Economy Plus", "model_qualifier": "40C", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 11.7, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001446", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Fuelsaver Economy Plus", "40C", "", "", "obsolete", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "11.7", "11.7", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1447, "brand_name": "Glow-worm", "model_name": "Fuelsaver Economy Plus", "model_qualifier": "50C", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 14.65, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001447", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Fuelsaver Economy Plus", "50C", "", "", "obsolete", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "14.65", "14.65", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1448, "brand_name": "Glow-worm", "model_name": "Fuelsaver Economy Plus", "model_qualifier": "60C", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 17.59, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001448", "000207", "0", "2010/Sep/13 17:03", "Glow-worm", "Glow-worm", "Fuelsaver Economy Plus", "60C", "", "", "obsolete", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "17.59", "17.59", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1464, "brand_name": "Maxol", "model_name": "Eastham", "model_qualifier": "25bf", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 7.62, "final_year_of_manufacture": 1980, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001464", "000007", "0", "2010/Sep/13 17:03", "Maxol", "Maxol", "Eastham", "25bf", "4120207", "", "1980", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "7.62", "7.62", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1465, "brand_name": "Maxol", "model_name": "Eastham", "model_qualifier": "25of", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 7.62, "final_year_of_manufacture": 1980, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001465", "000007", "0", "2010/Sep/13 17:03", "Maxol", "Maxol", "Eastham", "25of", "4120208", "", "1980", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "7.62", "7.62", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1467, "brand_name": "Maxol", "model_name": "Eastham", "model_qualifier": "40bf", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 13.19, "final_year_of_manufacture": 1980, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001467", "000007", "0", "2010/Sep/13 17:03", "Maxol", "Maxol", "Eastham", "40bf", "4120209", "", "1980", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "13.19", "13.19", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1468, "brand_name": "Maxol", "model_name": "Eastham", "model_qualifier": "50", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 16.12, "final_year_of_manufacture": 1980, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001468", "000007", "0", "2010/Sep/13 17:03", "Maxol", "Maxol", "Eastham", "50", "4120203", "", "1980", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "16.12", "16.12", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1469, "brand_name": "Maxol", "model_name": "Homewarm", "model_qualifier": "600", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 6.0, "final_year_of_manufacture": 1986, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001469", "000007", "0", "2010/Sep/13 17:03", "Maxol", "Maxol", "Homewarm", "600", "4120210", "", "1986", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "6", "6", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1470, "brand_name": "Maxol", "model_name": "Marathon", "model_qualifier": "e", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": null, "final_year_of_manufacture": 1975, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001470", "000007", "0", "2010/Sep/13 17:03", "Maxol", "Maxol", "Marathon", "e", "4420202", "", "1975", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "", "", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1471, "brand_name": "Maxol", "model_name": "Marathon", "model_qualifier": "mk1", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": null, "final_year_of_manufacture": 1975, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001471", "000007", "0", "2010/Sep/13 17:03", "Maxol", "Maxol", "Marathon", "mk1", "4420201", "", "1975", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "", "", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1472, "brand_name": "Maxol", "model_name": "Marathon", "model_qualifier": "mk1r", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": null, "final_year_of_manufacture": 1975, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001472", "000007", "0", "2010/Sep/13 17:03", "Maxol", "Maxol", "Marathon", "mk1r", "4420204", "", "1975", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "", "", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1473, "brand_name": "Maxol", "model_name": "Marathon", "model_qualifier": "r", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": null, "final_year_of_manufacture": 1975, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001473", "000007", "0", "2010/Sep/13 17:03", "Maxol", "Maxol", "Marathon", "r", "4420205", "", "1975", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "", "", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1474, "brand_name": "Maxol", "model_name": "Maxolympic", "model_qualifier": "15", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": null, "final_year_of_manufacture": 1977, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001474", "000007", "0", "2010/Sep/13 17:03", "Maxol", "Maxol", "Maxolympic", "15", "3920201", "", "1977", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "", "", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1475, "brand_name": "Maxol", "model_name": "Maxolympic", "model_qualifier": "f15", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": null, "final_year_of_manufacture": 1977, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001475", "000007", "0", "2010/Sep/13 17:03", "Maxol", "Maxol", "Maxolympic", "f15", "3920202", "", "1977", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "", "", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1476, "brand_name": "Maxol", "model_name": "Maxolympic", "model_qualifier": "f20", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": null, "final_year_of_manufacture": 1977, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001476", "000007", "0", "2010/Sep/13 17:03", "Maxol", "Maxol", "Maxolympic", "f20", "4420208", "", "1977", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "", "", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1477, "brand_name": "Maxol", "model_name": "Microturbo", "model_qualifier": "40mdf", "winter_efficiency_pct": 73.0, "summer_efficiency_pct": 63.0, "comparative_hot_water_efficiency_pct": 45.9, "output_kw_max": 11.72, "final_year_of_manufacture": 1992, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001477", "000007", "0", "2015/Jul/21 14:15", "Maxol", "Maxol", "Microturbo", "40mdf", "4120215", "", "1992", "1", "0", "0", "1", "0", "", "", "1", "2", "2", "11.72", "11.72", "", "", "73.0", "63.0", "", "45.9", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1478, "brand_name": "Maxol", "model_name": "Microturbo", "model_qualifier": "40rf", "winter_efficiency_pct": 73.0, "summer_efficiency_pct": 63.0, "comparative_hot_water_efficiency_pct": 45.9, "output_kw_max": 11.72, "final_year_of_manufacture": 1992, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001478", "000007", "0", "2015/Jul/21 14:15", "Maxol", "Maxol", "Microturbo", "40rf", "4120217", "", "1992", "1", "0", "0", "1", "0", "", "", "1", "2", "2", "11.72", "11.72", "", "", "73.0", "63.0", "", "45.9", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1479, "brand_name": "Maxol", "model_name": "Microturbo", "model_qualifier": "50mdf", "winter_efficiency_pct": 73.0, "summer_efficiency_pct": 63.0, "comparative_hot_water_efficiency_pct": 45.9, "output_kw_max": 14.6, "final_year_of_manufacture": 1995, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001479", "000007", "0", "2015/Jul/21 14:15", "Maxol", "Maxol", "Microturbo", "50mdf", "4120219", "", "1995", "1", "0", "0", "1", "0", "", "", "1", "2", "2", "14.6", "14.6", "", "", "73.0", "63.0", "", "45.9", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1480, "brand_name": "Maxol", "model_name": "Microturbo", "model_qualifier": "50rf", "winter_efficiency_pct": 73.0, "summer_efficiency_pct": 63.0, "comparative_hot_water_efficiency_pct": 45.9, "output_kw_max": 14.6, "final_year_of_manufacture": 1995, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001480", "000007", "0", "2015/Jul/21 14:15", "Maxol", "Maxol", "Microturbo", "50rf", "4120218", "", "1995", "1", "0", "0", "1", "0", "", "", "1", "2", "2", "14.6", "14.6", "", "", "73.0", "63.0", "", "45.9", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1485, "brand_name": "Maxol", "model_name": "Mystique", "model_qualifier": "coalridge", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": null, "final_year_of_manufacture": 1988, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001485", "000007", "0", "2010/Sep/13 17:03", "Maxol", "Maxol", "Mystique", "coalridge", "4420210", "", "1988", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "", "", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1486, "brand_name": "Maxol", "model_name": "Ruud", "model_qualifier": "118", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 34.6, "final_year_of_manufacture": 1975, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001486", "000007", "0", "2010/Sep/13 17:03", "Maxol", "Maxol", "Ruud", "118", "4120201", "", "1975", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "34.6", "34.6", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1494, "brand_name": "Thorn EMI Heating", "model_name": "Apollo", "model_qualifier": "30b", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 8.8, "final_year_of_manufacture": 1998, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001494", "000005", "0", "2010/Sep/13 17:03", "Thorn EMI Heating", "Thorn EMI Heating", "Apollo", "30b", "4149422", "", "1998", "1", "2", "1", "1", "0", "", "", "1", "2", "1", "4.4", "8.8", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "1", "20", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1495, "brand_name": "Thorn EMI Heating", "model_name": "Apollo", "model_qualifier": "30c", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 8.8, "final_year_of_manufacture": 1998, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001495", "000005", "0", "2010/Sep/13 17:03", "Thorn EMI Heating", "Thorn EMI Heating", "Apollo", "30c", "4149427", "", "1998", "1", "2", "1", "1", "0", "", "", "1", "1", "1", "4.4", "8.8", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "1", "20", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1496, "brand_name": "Thorn EMI Heating", "model_name": "Apollo", "model_qualifier": "30s", "winter_efficiency_pct": 73.0, "summer_efficiency_pct": 63.0, "comparative_hot_water_efficiency_pct": 45.9, "output_kw_max": 8.8, "final_year_of_manufacture": 1997, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001496", "000005", "0", "2015/Jul/21 14:15", "Thorn EMI Heating", "Thorn EMI Heating", "Apollo", "30s", "4149432", "", "1997", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "4.4", "8.8", "", "", "73.0", "63.0", "", "45.9", "", "3", "", "", "0", "2", "1", "60", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1497, "brand_name": "Thorn EMI Heating", "model_name": "Apollo", "model_qualifier": "30si", "winter_efficiency_pct": 73.0, "summer_efficiency_pct": 63.0, "comparative_hot_water_efficiency_pct": 45.9, "output_kw_max": 8.8, "final_year_of_manufacture": 1998, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001497", "000005", "0", "2015/Jul/21 14:15", "Thorn EMI Heating", "Thorn EMI Heating", "Apollo", "30si", "4149437", "", "1998", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "4.4", "8.8", "", "", "73.0", "63.0", "", "45.9", "", "3", "", "", "0", "1", "1", "60", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1498, "brand_name": "Thorn EMI Heating", "model_name": "Apollo", "model_qualifier": "40b", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 11.7, "final_year_of_manufacture": 1998, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001498", "000005", "0", "2010/Sep/13 17:03", "Thorn EMI Heating", "Thorn EMI Heating", "Apollo", "40b", "4149423", "", "1998", "1", "2", "1", "1", "0", "", "", "1", "2", "1", "8.8", "11.7", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "1", "20", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1499, "brand_name": "Thorn EMI Heating", "model_name": "Apollo", "model_qualifier": "40c", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 11.7, "final_year_of_manufacture": 1998, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001499", "000005", "0", "2010/Sep/13 17:03", "Thorn EMI Heating", "Thorn EMI Heating", "Apollo", "40c", "4149428", "", "1998", "1", "2", "1", "1", "0", "", "", "1", "1", "1", "8.8", "11.7", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "1", "20", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1500, "brand_name": "Thorn EMI Heating", "model_name": "Apollo", "model_qualifier": "40s", "winter_efficiency_pct": 73.0, "summer_efficiency_pct": 63.0, "comparative_hot_water_efficiency_pct": 45.9, "output_kw_max": 11.7, "final_year_of_manufacture": 1997, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001500", "000005", "0", "2015/Jul/21 14:15", "Thorn EMI Heating", "Thorn EMI Heating", "Apollo", "40s", "4149433", "", "1997", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "8.8", "11.7", "", "", "73.0", "63.0", "", "45.9", "", "3", "", "", "0", "2", "1", "60", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1501, "brand_name": "Thorn EMI Heating", "model_name": "Apollo", "model_qualifier": "40si", "winter_efficiency_pct": 73.0, "summer_efficiency_pct": 63.0, "comparative_hot_water_efficiency_pct": 45.9, "output_kw_max": 11.7, "final_year_of_manufacture": 1998, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001501", "000005", "0", "2015/Jul/21 14:15", "Thorn EMI Heating", "Thorn EMI Heating", "Apollo", "40si", "4149438", "", "1998", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "8.8", "11.7", "", "", "73.0", "63.0", "", "45.9", "", "3", "", "", "0", "1", "1", "60", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1502, "brand_name": "Thorn EMI Heating", "model_name": "Apollo", "model_qualifier": "50b", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 14.7, "final_year_of_manufacture": 1998, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001502", "000005", "0", "2010/Sep/13 17:03", "Thorn EMI Heating", "Thorn EMI Heating", "Apollo", "50b", "4149424", "", "1998", "1", "2", "1", "1", "0", "", "", "1", "2", "1", "11.7", "14.7", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "1", "20", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1503, "brand_name": "Thorn EMI Heating", "model_name": "Apollo", "model_qualifier": "50c", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 14.7, "final_year_of_manufacture": 1998, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001503", "000005", "0", "2010/Sep/13 17:03", "Thorn EMI Heating", "Thorn EMI Heating", "Apollo", "50c", "4149429", "", "1998", "1", "2", "1", "1", "0", "", "", "1", "1", "1", "11.7", "14.7", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "1", "20", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1504, "brand_name": "Thorn EMI Heating", "model_name": "Apollo", "model_qualifier": "50s", "winter_efficiency_pct": 73.0, "summer_efficiency_pct": 63.0, "comparative_hot_water_efficiency_pct": 45.9, "output_kw_max": 14.7, "final_year_of_manufacture": 1997, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001504", "000005", "0", "2015/Jul/21 14:15", "Thorn EMI Heating", "Thorn EMI Heating", "Apollo", "50s", "4149434", "", "1997", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "11.7", "14.7", "", "", "73.0", "63.0", "", "45.9", "", "3", "", "", "0", "2", "1", "60", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1505, "brand_name": "Thorn EMI Heating", "model_name": "Apollo", "model_qualifier": "50si", "winter_efficiency_pct": 73.0, "summer_efficiency_pct": 63.0, "comparative_hot_water_efficiency_pct": 45.9, "output_kw_max": 14.7, "final_year_of_manufacture": 1998, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001505", "000005", "0", "2015/Jul/21 14:15", "Thorn EMI Heating", "Thorn EMI Heating", "Apollo", "50si", "4149439", "", "1998", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "11.7", "14.7", "", "", "73.0", "63.0", "", "45.9", "", "3", "", "", "0", "1", "1", "60", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1506, "brand_name": "Thorn EMI Heating", "model_name": "Apollo", "model_qualifier": "60b", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 17.6, "final_year_of_manufacture": 1998, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001506", "000005", "0", "2010/Sep/13 17:03", "Thorn EMI Heating", "Thorn EMI Heating", "Apollo", "60b", "4149425", "", "1998", "1", "2", "1", "1", "0", "", "", "1", "2", "1", "14.7", "17.6", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "1", "20", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1507, "brand_name": "Thorn EMI Heating", "model_name": "Apollo", "model_qualifier": "60c", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 17.6, "final_year_of_manufacture": 1998, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001507", "000005", "0", "2010/Sep/13 17:03", "Thorn EMI Heating", "Thorn EMI Heating", "Apollo", "60c", "4149430", "", "1998", "1", "2", "1", "1", "0", "", "", "1", "1", "1", "14.7", "17.6", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "1", "20", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1508, "brand_name": "Thorn EMI Heating", "model_name": "Apollo", "model_qualifier": "60si", "winter_efficiency_pct": 73.0, "summer_efficiency_pct": 63.0, "comparative_hot_water_efficiency_pct": 45.9, "output_kw_max": 17.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001508", "000005", "0", "2015/Jul/21 14:15", "Thorn EMI Heating", "Thorn EMI Heating", "Apollo", "60si", "4149440", "", "obsolete", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "14.7", "17.6", "", "", "73.0", "63.0", "", "45.9", "", "3", "", "", "0", "1", "1", "60", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1509, "brand_name": "Thorn EMI Heating", "model_name": "Apollo", "model_qualifier": "80b", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 23.4, "final_year_of_manufacture": 1998, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001509", "000005", "0", "2010/Sep/13 17:03", "Thorn EMI Heating", "Thorn EMI Heating", "Apollo", "80b", "4149426", "", "1998", "1", "2", "1", "1", "0", "", "", "1", "2", "1", "17.6", "23.4", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "1", "20", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1510, "brand_name": "Thorn EMI Heating", "model_name": "Apollo", "model_qualifier": "80c", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 23.4, "final_year_of_manufacture": 1998, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001510", "000005", "0", "2010/Sep/13 17:03", "Thorn EMI Heating", "Thorn EMI Heating", "Apollo", "80c", "4149431", "", "1998", "1", "2", "1", "1", "0", "", "", "1", "1", "1", "17.6", "23.4", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "1", "20", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1511, "brand_name": "Thorn EMI Heating", "model_name": "Apollo", "model_qualifier": "80si", "winter_efficiency_pct": 73.0, "summer_efficiency_pct": 63.0, "comparative_hot_water_efficiency_pct": 45.9, "output_kw_max": 23.4, "final_year_of_manufacture": 1998, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001511", "000005", "0", "2015/Jul/21 14:15", "Thorn EMI Heating", "Thorn EMI Heating", "Apollo", "80si", "4149441", "", "1998", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "17.6", "23.4", "", "", "73.0", "63.0", "", "45.9", "", "3", "", "", "0", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1512, "brand_name": "Potterton Myson Heating", "model_name": "Economist", "model_qualifier": "wm15/30bf", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 8.8, "final_year_of_manufacture": 1987, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001512", "000005", "0", "2010/Sep/13 17:03", "Potterton Myson Heating", "Potterton Myson Heating", "Economist", "wm15/30bf", "4183881", "", "1987", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "8.8", "8.8", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1513, "brand_name": "Myson Combustion Products", "model_name": "Economist", "model_qualifier": "wm15/30bfa", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 8.8, "final_year_of_manufacture": 1997, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001513", "000005", "0", "2010/Sep/13 17:03", "Myson Combustion Products", "Myson Combustion Products", "Economist", "wm15/30bfa", "4183890", "", "1997", "1", "2", "1", "1", "0", "", "", "1", "2", "1", "4.4", "8.8", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1514, "brand_name": "Myson Combustion Products", "model_name": "Economist", "model_qualifier": "wm30/40bf", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 11.7, "final_year_of_manufacture": 1997, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001514", "000005", "0", "2010/Sep/13 17:03", "Myson Combustion Products", "Myson Combustion Products", "Economist", "wm30/40bf", "4183882", "", "1997", "1", "2", "1", "1", "0", "", "", "1", "2", "1", "8.8", "11.7", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1515, "brand_name": "Myson Combustion Products", "model_name": "Economist", "model_qualifier": "wm40/50bf", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 14.7, "final_year_of_manufacture": 1997, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001515", "000005", "0", "2010/Sep/13 17:03", "Myson Combustion Products", "Myson Combustion Products", "Economist", "wm40/50bf", "4183885", "", "1997", "1", "2", "1", "1", "0", "", "", "1", "2", "1", "11.7", "14.7", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1516, "brand_name": "Myson Combustion Products", "model_name": "Economist", "model_qualifier": "wm50/60bf", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 17.6, "final_year_of_manufacture": 1997, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001516", "000005", "0", "2010/Sep/13 17:03", "Myson Combustion Products", "Myson Combustion Products", "Economist", "wm50/60bf", "4183884", "", "1997", "1", "2", "1", "1", "0", "", "", "1", "2", "1", "14.7", "17.6", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1517, "brand_name": "Myson Combustion Products", "model_name": "Economist", "model_qualifier": "wm60/80bf", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 23.5, "final_year_of_manufacture": 1997, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001517", "000005", "0", "2010/Sep/13 17:03", "Myson Combustion Products", "Myson Combustion Products", "Economist", "wm60/80bf", "4183888", "", "1997", "1", "2", "1", "1", "0", "", "", "1", "2", "1", "17.6", "23.5", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1518, "brand_name": "Myson Combustion Products", "model_name": "Economist", "model_qualifier": "wm80/100bf", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 28.4, "final_year_of_manufacture": 1997, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001518", "000005", "0", "2010/Sep/13 17:03", "Myson Combustion Products", "Myson Combustion Products", "Economist", "wm80/100bf", "4183889", "", "1997", "1", "2", "1", "1", "0", "", "", "1", "2", "1", "23.5", "28.4", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1519, "brand_name": "Thorn EMI Heating", "model_name": "Housewarmer", "model_qualifier": "30/45economy", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": null, "final_year_of_manufacture": 1988, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001519", "000005", "0", "2010/Sep/13 17:03", "Thorn EMI Heating", "Thorn EMI Heating", "Housewarmer", "30/45economy", "4478915", "", "1988", "1", "4", "1", "1", "0", "", "", "1", "1", "1", "", "", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1520, "brand_name": "Thorn EMI Heating", "model_name": "Housewarmer", "model_qualifier": "30/45elegant", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": null, "final_year_of_manufacture": 1988, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001520", "000005", "0", "2010/Sep/13 17:03", "Thorn EMI Heating", "Thorn EMI Heating", "Housewarmer", "30/45elegant", "4478916", "", "1988", "1", "4", "0", "1", "0", "", "", "1", "1", "1", "", "", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1521, "brand_name": "Thorn EMI Heating", "model_name": "Housewarmer", "model_qualifier": "30/45epic", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": null, "final_year_of_manufacture": 1987, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001521", "000005", "0", "2010/Sep/13 17:03", "Thorn EMI Heating", "Thorn EMI Heating", "Housewarmer", "30/45epic", "4478917", "", "1987", "1", "4", "0", "1", "0", "", "", "1", "1", "1", "", "", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1522, "brand_name": "Thorn EMI Heating", "model_name": "Housewarmer", "model_qualifier": "30/45epictc", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": null, "final_year_of_manufacture": 1990, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001522", "000005", "0", "2010/Sep/13 17:03", "Thorn EMI Heating", "Thorn EMI Heating", "Housewarmer", "30/45epictc", "4449401", "", "1990", "1", "4", "0", "1", "0", "", "", "1", "1", "1", "", "", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1523, "brand_name": "Thorn EMI Heating", "model_name": "Housewarmer", "model_qualifier": "30/45extratc", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": null, "final_year_of_manufacture": 1987, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001523", "000005", "0", "2010/Sep/13 17:03", "Thorn EMI Heating", "Thorn EMI Heating", "Housewarmer", "30/45extratc", "4478923", "", "1987", "1", "4", "0", "1", "0", "", "", "1", "1", "1", "", "", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1524, "brand_name": "Thorn EMI Heating", "model_name": "Housewarmer", "model_qualifier": "30/45sable", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": null, "final_year_of_manufacture": 1990, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001524", "000005", "0", "2010/Sep/13 17:03", "Thorn EMI Heating", "Thorn EMI Heating", "Housewarmer", "30/45sable", "4449402", "", "1990", "1", "4", "0", "1", "0", "", "", "1", "1", "1", "", "", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1525, "brand_name": "Thorn EMI Heating", "model_name": "Housewarmer", "model_qualifier": "30/45snug", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": null, "final_year_of_manufacture": 1987, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001525", "000005", "0", "2010/Sep/13 17:03", "Thorn EMI Heating", "Thorn EMI Heating", "Housewarmer", "30/45snug", "4478918", "", "1987", "1", "4", "0", "1", "0", "", "", "1", "1", "1", "", "", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1526, "brand_name": "Thorn EMI Heating", "model_name": "Housewarmer", "model_qualifier": "30/45spectacular", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": null, "final_year_of_manufacture": 1988, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001526", "000005", "0", "2010/Sep/13 17:03", "Thorn EMI Heating", "Thorn EMI Heating", "Housewarmer", "30/45spectacular", "4478922", "", "1988", "1", "4", "0", "1", "0", "", "", "1", "1", "1", "", "", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1527, "brand_name": "Thorn EMI Heating", "model_name": "Housewarmer", "model_qualifier": "30/45superior", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": null, "final_year_of_manufacture": 1990, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001527", "000005", "0", "2010/Sep/13 17:03", "Thorn EMI Heating", "Thorn EMI Heating", "Housewarmer", "30/45superior", "4478919", "", "1990", "1", "4", "0", "1", "0", "", "", "1", "1", "1", "", "", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1528, "brand_name": "Thorn EMI Heating", "model_name": "Housewarmer", "model_qualifier": "30/45supreme", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": null, "final_year_of_manufacture": 1990, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001528", "000005", "0", "2010/Sep/13 17:03", "Thorn EMI Heating", "Thorn EMI Heating", "Housewarmer", "30/45supreme", "4478920", "", "1990", "1", "4", "0", "1", "0", "", "", "1", "1", "1", "", "", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1529, "brand_name": "Thorn EMI Heating", "model_name": "Housewarmer", "model_qualifier": "45", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": null, "final_year_of_manufacture": 1994, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001529", "000005", "0", "2010/Sep/13 17:03", "Thorn EMI Heating", "Thorn EMI Heating", "Housewarmer", "45", "", "", "1994", "1", "4", "0", "1", "0", "", "", "1", "1", "1", "", "", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1530, "brand_name": "Thorn EMI Heating", "model_name": "Housewarmer", "model_qualifier": "55", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": null, "final_year_of_manufacture": 1994, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001530", "000005", "0", "2010/Sep/13 17:03", "Thorn EMI Heating", "Thorn EMI Heating", "Housewarmer", "55", "", "", "1994", "1", "4", "0", "1", "0", "", "", "1", "1", "1", "", "", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1531, "brand_name": "Thorn EMI Heating", "model_name": "Housewarmer", "model_qualifier": "deluxe", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": null, "final_year_of_manufacture": 1981, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001531", "000005", "0", "2010/Sep/13 17:03", "Thorn EMI Heating", "Thorn EMI Heating", "Housewarmer", "deluxe", "4478909", "", "1981", "1", "4", "0", "1", "0", "", "", "1", "1", "1", "", "", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1532, "brand_name": "Thorn EMI Heating", "model_name": "Housewarmer", "model_qualifier": "elite", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": null, "final_year_of_manufacture": 1990, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001532", "000005", "0", "2010/Sep/13 17:03", "Thorn EMI Heating", "Thorn EMI Heating", "Housewarmer", "elite", "4449403", "", "1990", "1", "4", "0", "1", "0", "", "", "1", "1", "1", "", "", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1534, "brand_name": "Thorn EMI Heating", "model_name": "Housewarmer", "model_qualifier": "emodel", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": null, "final_year_of_manufacture": 1976, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001534", "000005", "0", "2010/Sep/13 17:03", "Thorn EMI Heating", "Thorn EMI Heating", "Housewarmer", "emodel", "4478903", "", "1976", "1", "4", "0", "1", "0", "", "", "1", "1", "1", "", "", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1535, "brand_name": "Thorn EMI Heating", "model_name": "Housewarmer", "model_qualifier": "smodel", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": null, "final_year_of_manufacture": 1981, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001535", "000005", "0", "2010/Sep/13 17:03", "Thorn EMI Heating", "Thorn EMI Heating", "Housewarmer", "smodel", "4478907", "", "1981", "1", "4", "0", "1", "0", "", "", "1", "1", "1", "", "", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1536, "brand_name": "Potterton Myson Heating", "model_name": "Housewarmer", "model_qualifier": "smodel", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": null, "final_year_of_manufacture": 1976, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001536", "000005", "0", "2010/Sep/13 17:03", "Potterton Myson Heating", "Potterton Myson Heating", "Housewarmer", "smodel", "4478904", "", "1976", "1", "4", "0", "1", "0", "", "", "1", "1", "1", "", "", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1537, "brand_name": "Thorn EMI Heating", "model_name": "Housewarmer", "model_qualifier": "spectaculardeluxe", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": null, "final_year_of_manufacture": 1990, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001537", "000005", "0", "2015/Jul/13 13:45", "Thorn EMI Heating", "Thorn EMI Heating", "Housewarmer", "spectaculardeluxe", "4478925", "", "1990", "1", "4", "0", "1", "0", "", "", "1", "1", "1", "", "", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1538, "brand_name": "Thorn EMI Heating", "model_name": "Housewarmer", "model_qualifier": "spectaculars", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": null, "final_year_of_manufacture": 1988, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001538", "000005", "0", "2010/Sep/13 17:03", "Thorn EMI Heating", "Thorn EMI Heating", "Housewarmer", "spectaculars", "4478924", "", "1988", "1", "4", "0", "1", "0", "", "", "1", "1", "1", "", "", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1539, "brand_name": "Thorn EMI Heating", "model_name": "Housewarmer", "model_qualifier": "super", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": null, "final_year_of_manufacture": 1981, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001539", "000005", "0", "2010/Sep/13 17:03", "Thorn EMI Heating", "Thorn EMI Heating", "Housewarmer", "super", "4478908", "", "1981", "1", "4", "0", "1", "0", "", "", "1", "1", "1", "", "", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1540, "brand_name": "Thorn EMI Heating", "model_name": "Housewarmer 2", "model_qualifier": "30/45deluxe", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": null, "final_year_of_manufacture": 1983, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001540", "000005", "0", "2010/Sep/13 17:03", "Thorn EMI Heating", "Thorn EMI Heating", "Housewarmer 2", "30/45deluxe", "4478913", "", "1983", "1", "4", "0", "1", "0", "", "", "1", "1", "1", "", "", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1541, "brand_name": "Thorn EMI Heating", "model_name": "Housewarmer 2", "model_qualifier": "30/45e", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": null, "final_year_of_manufacture": 1983, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001541", "000005", "0", "2010/Sep/13 17:03", "Thorn EMI Heating", "Thorn EMI Heating", "Housewarmer 2", "30/45e", "4478910", "", "1983", "1", "4", "0", "1", "0", "", "", "1", "1", "1", "", "", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1542, "brand_name": "Thorn EMI Heating", "model_name": "Housewarmer 2", "model_qualifier": "30/45eplus", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": null, "final_year_of_manufacture": 1983, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001542", "000005", "0", "2010/Sep/13 17:03", "Thorn EMI Heating", "Thorn EMI Heating", "Housewarmer 2", "30/45eplus", "4478914", "", "1983", "1", "4", "0", "1", "0", "", "", "1", "1", "1", "", "", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1543, "brand_name": "Thorn EMI Heating", "model_name": "Housewarmer 2", "model_qualifier": "30/45s", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": null, "final_year_of_manufacture": 1983, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001543", "000005", "0", "2010/Sep/13 17:03", "Thorn EMI Heating", "Thorn EMI Heating", "Housewarmer 2", "30/45s", "4478911", "", "1983", "1", "4", "0", "1", "0", "", "", "1", "1", "1", "", "", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1544, "brand_name": "Thorn EMI Heating", "model_name": "Housewarmer 2", "model_qualifier": "30/45super", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": null, "final_year_of_manufacture": 1983, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001544", "000005", "0", "2010/Sep/13 17:03", "Thorn EMI Heating", "Thorn EMI Heating", "Housewarmer 2", "30/45super", "4478912", "", "1983", "1", "4", "0", "1", "0", "", "", "1", "1", "1", "", "", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1545, "brand_name": "Thorn EMI Heating", "model_name": "Housewarmer Mk2", "model_qualifier": "30/45extra", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": null, "final_year_of_manufacture": 1985, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001545", "000005", "0", "2010/Sep/13 17:03", "Thorn EMI Heating", "Thorn EMI Heating", "Housewarmer Mk2", "30/45extra", "4478921", "", "1985", "1", "4", "0", "1", "0", "", "", "1", "1", "1", "", "", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1546, "brand_name": "Thorn EMI Heating", "model_name": "International", "model_qualifier": "40deluxe", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": null, "final_year_of_manufacture": 1972, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001546", "000005", "0", "2010/Sep/13 17:03", "Thorn EMI Heating", "Thorn EMI Heating", "International", "40deluxe", "4441101", "", "1972", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "", "", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1547, "brand_name": "Thorn EMI Heating", "model_name": "Marathon", "model_qualifier": "1000b", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 27.0, "final_year_of_manufacture": 1997, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001547", "000005", "0", "2010/Sep/13 17:03", "Thorn EMI Heating", "Thorn EMI Heating", "Marathon", "1000b", "4149413", "", "1997", "1", "1", "1", "1", "0", "", "", "1", "2", "1", "27", "27", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "1", "20", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1548, "brand_name": "Thorn EMI Heating", "model_name": "Marathon", "model_qualifier": "1000c", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 27.8, "final_year_of_manufacture": 1997, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001548", "000005", "0", "2010/Sep/13 17:03", "Thorn EMI Heating", "Thorn EMI Heating", "Marathon", "1000c", "4149419", "", "1997", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "27.8", "27.8", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "1", "20", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1549, "brand_name": "Thorn EMI Heating", "model_name": "Marathon", "model_qualifier": "1500c", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 41.47, "final_year_of_manufacture": 1997, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001549", "000005", "0", "2010/Sep/13 17:03", "Thorn EMI Heating", "Thorn EMI Heating", "Marathon", "1500c", "4149420", "", "1997", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "41.47", "41.47", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "1", "20", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1550, "brand_name": "Thorn EMI Heating", "model_name": "Marathon", "model_qualifier": "400b", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 11.7, "final_year_of_manufacture": 1997, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001550", "000005", "0", "2010/Sep/13 17:03", "Thorn EMI Heating", "Thorn EMI Heating", "Marathon", "400b", "4149408", "", "1997", "1", "1", "1", "1", "0", "", "", "1", "2", "1", "8.8", "11.7", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "1", "20", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1551, "brand_name": "Thorn EMI Heating", "model_name": "Marathon", "model_qualifier": "400c", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 11.7, "final_year_of_manufacture": 1997, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001551", "000005", "0", "2010/Sep/13 17:03", "Thorn EMI Heating", "Thorn EMI Heating", "Marathon", "400c", "4149414", "", "1997", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "8.8", "11.7", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "1", "20", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1552, "brand_name": "Thorn EMI Heating", "model_name": "Marathon", "model_qualifier": "500b", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 14.7, "final_year_of_manufacture": 1997, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001552", "000005", "0", "2010/Sep/13 17:03", "Thorn EMI Heating", "Thorn EMI Heating", "Marathon", "500b", "4149409", "", "1997", "1", "1", "1", "1", "0", "", "", "1", "2", "1", "11.7", "14.7", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "1", "20", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1553, "brand_name": "Thorn EMI Heating", "model_name": "Marathon", "model_qualifier": "500c", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 14.7, "final_year_of_manufacture": 1997, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001553", "000005", "0", "2010/Sep/13 17:03", "Thorn EMI Heating", "Thorn EMI Heating", "Marathon", "500c", "4149415", "", "1997", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "11.7", "14.7", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "1", "20", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1554, "brand_name": "Thorn EMI Heating", "model_name": "Marathon", "model_qualifier": "600b", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 17.6, "final_year_of_manufacture": 1997, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001554", "000005", "0", "2010/Sep/13 17:03", "Thorn EMI Heating", "Thorn EMI Heating", "Marathon", "600b", "4149410", "", "1997", "1", "1", "1", "1", "0", "", "", "1", "2", "1", "14.7", "17.6", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "1", "20", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1555, "brand_name": "Thorn EMI Heating", "model_name": "Marathon", "model_qualifier": "600c", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 17.6, "final_year_of_manufacture": 1997, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001555", "000005", "0", "2010/Sep/13 17:03", "Thorn EMI Heating", "Thorn EMI Heating", "Marathon", "600c", "4149416", "", "1997", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "14.7", "17.6", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "1", "20", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1556, "brand_name": "Thorn EMI Heating", "model_name": "Marathon", "model_qualifier": "700b", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 20.5, "final_year_of_manufacture": 1997, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001556", "000005", "0", "2010/Sep/13 17:03", "Thorn EMI Heating", "Thorn EMI Heating", "Marathon", "700b", "4149411", "", "1997", "1", "1", "1", "1", "0", "", "", "1", "2", "1", "17.6", "20.5", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "1", "20", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1557, "brand_name": "Thorn EMI Heating", "model_name": "Marathon", "model_qualifier": "700c", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 20.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001557", "000005", "0", "2010/Sep/13 17:03", "Thorn EMI Heating", "Thorn EMI Heating", "Marathon", "700c", "4149417", "", "obsolete", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "17.6", "20.5", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1558, "brand_name": "Thorn EMI Heating", "model_name": "Marathon", "model_qualifier": "800b", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 23.5, "final_year_of_manufacture": 1997, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001558", "000005", "0", "2010/Sep/13 17:03", "Thorn EMI Heating", "Thorn EMI Heating", "Marathon", "800b", "4149412", "", "1997", "1", "1", "1", "1", "0", "", "", "1", "2", "1", "20.5", "23.5", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "1", "20", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1559, "brand_name": "Thorn EMI Heating", "model_name": "Marathon", "model_qualifier": "800c", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 23.5, "final_year_of_manufacture": 1997, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001559", "000005", "0", "2010/Sep/13 17:03", "Thorn EMI Heating", "Thorn EMI Heating", "Marathon", "800c", "4149418", "", "1997", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "20.5", "23.5", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "1", "20", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1560, "brand_name": "Potterton Myson Heating", "model_name": "Wilson", "model_qualifier": "ga40bf", "winter_efficiency_pct": 56.0, "summer_efficiency_pct": 46.0, "comparative_hot_water_efficiency_pct": 33.5, "output_kw_max": 10.7, "final_year_of_manufacture": 1975, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001560", "000005", "0", "2010/Sep/13 17:03", "Potterton Myson Heating", "Potterton Myson Heating", "Wilson", "ga40bf", "4183841", "", "1975", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "10.7", "10.7", "", "", "56.0", "46.0", "", "33.5", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1561, "brand_name": "Potterton Myson Heating", "model_name": "Wilson", "model_qualifier": "ga40cf", "winter_efficiency_pct": 56.0, "summer_efficiency_pct": 46.0, "comparative_hot_water_efficiency_pct": 33.5, "output_kw_max": 10.7, "final_year_of_manufacture": 1975, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001561", "000005", "0", "2010/Sep/13 17:03", "Potterton Myson Heating", "Potterton Myson Heating", "Wilson", "ga40cf", "4183840", "", "1975", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "10.7", "10.7", "", "", "56.0", "46.0", "", "33.5", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1562, "brand_name": "Potterton Myson Heating", "model_name": "Wilson", "model_qualifier": "ga53bf", "winter_efficiency_pct": 56.0, "summer_efficiency_pct": 46.0, "comparative_hot_water_efficiency_pct": 33.5, "output_kw_max": 14.35, "final_year_of_manufacture": 1975, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001562", "000005", "0", "2010/Sep/13 17:03", "Potterton Myson Heating", "Potterton Myson Heating", "Wilson", "ga53bf", "4183843", "", "1975", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "14.35", "14.35", "", "", "56.0", "46.0", "", "33.5", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1563, "brand_name": "Potterton Myson Heating", "model_name": "Wilson", "model_qualifier": "ga53cf", "winter_efficiency_pct": 56.0, "summer_efficiency_pct": 46.0, "comparative_hot_water_efficiency_pct": 33.5, "output_kw_max": 14.35, "final_year_of_manufacture": 1975, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001563", "000005", "0", "2010/Sep/13 17:03", "Potterton Myson Heating", "Potterton Myson Heating", "Wilson", "ga53cf", "4183842", "", "1975", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "14.35", "14.35", "", "", "56.0", "46.0", "", "33.5", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1564, "brand_name": "Potterton Myson Heating", "model_name": "Wilson", "model_qualifier": "ga70bf", "winter_efficiency_pct": 56.0, "summer_efficiency_pct": 46.0, "comparative_hot_water_efficiency_pct": 33.5, "output_kw_max": 19.7, "final_year_of_manufacture": 1975, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001564", "000005", "0", "2010/Sep/13 17:03", "Potterton Myson Heating", "Potterton Myson Heating", "Wilson", "ga70bf", "4183845", "", "1975", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "19.7", "19.7", "", "", "56.0", "46.0", "", "33.5", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1565, "brand_name": "Potterton Myson Heating", "model_name": "Wilson", "model_qualifier": "ga70cf", "winter_efficiency_pct": 56.0, "summer_efficiency_pct": 46.0, "comparative_hot_water_efficiency_pct": 33.5, "output_kw_max": 19.7, "final_year_of_manufacture": 1975, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001565", "000005", "0", "2010/Sep/13 17:03", "Potterton Myson Heating", "Potterton Myson Heating", "Wilson", "ga70cf", "4183844", "", "1975", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "19.7", "19.7", "", "", "56.0", "46.0", "", "33.5", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1568, "brand_name": "Oceanspa", "model_name": "Ocean", "model_qualifier": "80ff", "winter_efficiency_pct": 71.0, "summer_efficiency_pct": 62.0, "comparative_hot_water_efficiency_pct": 43.2, "output_kw_max": 23.4, "final_year_of_manufacture": 1995, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001568", "000083", "0", "2010/Sep/13 17:03", "Oceanspa", "Oceanspa", "Ocean", "80ff", "4753201", "", "1995", "1", "0", "0", "2", "0", "", "", "1", "2", "2", "23.4", "23.4", "", "", "71.0", "62.0", "", "43.2", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1569, "brand_name": "Oceanspa", "model_name": "Ocean", "model_qualifier": "80ffstyle", "winter_efficiency_pct": 71.0, "summer_efficiency_pct": 62.0, "comparative_hot_water_efficiency_pct": 43.2, "output_kw_max": 17.6, "final_year_of_manufacture": 1995, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001569", "000083", "0", "2010/Sep/13 17:03", "Oceanspa", "Oceanspa", "Ocean", "80ffstyle", "4753202", "", "1995", "1", "0", "0", "2", "0", "", "", "1", "2", "2", "17.6", "17.6", "", "", "71.0", "62.0", "", "43.2", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1570, "brand_name": "Oceanspa", "model_name": "Ocean", "model_qualifier": "80ofstyle", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 57.0, "comparative_hot_water_efficiency_pct": 39.7, "output_kw_max": 17.6, "final_year_of_manufacture": 1995, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001570", "000083", "0", "2010/Sep/13 17:03", "Oceanspa", "Oceanspa", "Ocean", "80ofstyle", "4735203", "", "1995", "1", "0", "0", "2", "0", "", "", "1", "1", "1", "17.6", "17.6", "", "", "66.0", "57.0", "", "39.7", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1571, "brand_name": "Parkray", "model_name": "Parkray", "model_qualifier": "401", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": null, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001571", "000020", "0", "2010/Sep/13 17:03", "Parkray", "Parkray", "Parkray", "401", "4462001", "", "obsolete", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "", "", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1572, "brand_name": "Parkray", "model_name": "Parkray", "model_qualifier": "402", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": null, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001572", "000020", "0", "2010/Sep/13 17:03", "Parkray", "Parkray", "Parkray", "402", "4462003", "", "obsolete", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "", "", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1573, "brand_name": "Parkray", "model_name": "Parkray", "model_qualifier": "404", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": null, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001573", "000020", "0", "2010/Sep/13 17:03", "Parkray", "Parkray", "Parkray", "404", "4462002", "", "obsolete", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "", "", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1574, "brand_name": "Powermatic", "model_name": "Sgm", "model_qualifier": "3gb", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 17.59, "final_year_of_manufacture": 1988, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001574", "000085", "0", "2010/Sep/13 17:03", "Powermatic", "Powermatic", "Sgm", "3gb", "4128301", "", "1988", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "17.59", "17.59", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1575, "brand_name": "Powermatic", "model_name": "Sgm", "model_qualifier": "4gb", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 26.39, "final_year_of_manufacture": 1988, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001575", "000085", "0", "2010/Sep/13 17:03", "Powermatic", "Powermatic", "Sgm", "4gb", "4128302", "", "1988", "1", "0", "0", "1", "0", "", "", "1", "1", "1", "26.39", "26.39", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1581, "brand_name": "R H Ingham", "model_name": "Ingham Danesmoor", "model_qualifier": "42", "winter_efficiency_pct": 65.0, "summer_efficiency_pct": 53.0, "comparative_hot_water_efficiency_pct": 38.9, "output_kw_max": 12.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001581", "000035", "0", "2010/Sep/13 17:03", "R H Ingham", "R H Ingham", "Ingham Danesmoor", "42", "", "", "obsolete", "4", "1", "1", "1", "0", "", "", "1", "1", "1", "12.3", "12.3", "", "", "65.0", "53.0", "", "38.9", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1582, "brand_name": "R H Ingham", "model_name": "Ingham Danesmoor", "model_qualifier": "60", "winter_efficiency_pct": 65.0, "summer_efficiency_pct": 53.0, "comparative_hot_water_efficiency_pct": 38.9, "output_kw_max": 17.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001582", "000035", "0", "2010/Sep/13 17:03", "R H Ingham", "R H Ingham", "Ingham Danesmoor", "60", "", "", "obsolete", "4", "1", "1", "1", "0", "", "", "1", "1", "1", "17.6", "17.6", "", "", "65.0", "53.0", "", "38.9", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1583, "brand_name": "R H Ingham", "model_name": "Ingham Danesmoor", "model_qualifier": "80", "winter_efficiency_pct": 65.0, "summer_efficiency_pct": 53.0, "comparative_hot_water_efficiency_pct": 38.9, "output_kw_max": 23.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001583", "000035", "0", "2010/Sep/13 17:03", "R H Ingham", "R H Ingham", "Ingham Danesmoor", "80", "", "", "obsolete", "4", "1", "1", "1", "0", "", "", "1", "1", "1", "23.4", "23.4", "", "", "65.0", "53.0", "", "38.9", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1584, "brand_name": "R H Ingham", "model_name": "Ingham Danesmoor", "model_qualifier": "ABK 60/100", "winter_efficiency_pct": 65.0, "summer_efficiency_pct": 53.0, "comparative_hot_water_efficiency_pct": 38.9, "output_kw_max": 17.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001584", "000035", "0", "2010/Sep/13 17:03", "R H Ingham", "R H Ingham", "Ingham Danesmoor", "ABK 60/100", "", "", "obsolete", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "17.6", "17.6", "", "", "65.0", "53.0", "", "38.9", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1585, "brand_name": "R H Ingham", "model_name": "Ingham Danesmoor", "model_qualifier": "PJ20/30", "winter_efficiency_pct": 65.0, "summer_efficiency_pct": 53.0, "comparative_hot_water_efficiency_pct": 38.9, "output_kw_max": 22.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001585", "000035", "0", "2010/Sep/13 17:03", "R H Ingham", "R H Ingham", "Ingham Danesmoor", "PJ20/30", "", "", "obsolete", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "22", "22", "", "", "65.0", "53.0", "", "38.9", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1586, "brand_name": "R H Ingham", "model_name": "Ingham Danesmoor", "model_qualifier": "PJ 20/30", "winter_efficiency_pct": 65.0, "summer_efficiency_pct": 53.0, "comparative_hot_water_efficiency_pct": 38.9, "output_kw_max": 26.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001586", "000035", "0", "2010/Sep/13 17:03", "R H Ingham", "R H Ingham", "Ingham Danesmoor", "PJ 20/30", "", "", "obsolete", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "26.4", "26.4", "", "", "65.0", "53.0", "", "38.9", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1588, "brand_name": "R H Ingham", "model_name": "Ingham Danesmoor", "model_qualifier": "PJ 30/45", "winter_efficiency_pct": 65.0, "summer_efficiency_pct": 53.0, "comparative_hot_water_efficiency_pct": 38.9, "output_kw_max": 35.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001588", "000035", "0", "2010/Sep/13 17:03", "R H Ingham", "R H Ingham", "Ingham Danesmoor", "PJ 30/45", "", "", "obsolete", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "29.3", "35.2", "", "", "65.0", "53.0", "", "38.9", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1603, "brand_name": "Trianco", "model_name": "Centramatic M", "model_qualifier": "", "winter_efficiency_pct": 65.0, "summer_efficiency_pct": 53.0, "comparative_hot_water_efficiency_pct": 38.9, "output_kw_max": 12.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001603", "000062", "0", "2010/Sep/13 17:03", "Trianco Redfyre", "Trianco", "Centramatic M", "", "", "", "obsolete", "4", "0", "0", "1", "0", "", "", "1", "1", "1", "12.3", "12.3", "", "", "65.0", "53.0", "", "38.9", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1604, "brand_name": "Trianco", "model_name": "Centramatic", "model_qualifier": "40", "winter_efficiency_pct": 65.0, "summer_efficiency_pct": 53.0, "comparative_hot_water_efficiency_pct": 38.9, "output_kw_max": 12.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001604", "000062", "0", "2010/Sep/13 17:03", "Trianco Redfyre", "Trianco", "Centramatic", "40", "", "", "obsolete", "4", "0", "0", "1", "0", "", "", "1", "1", "1", "12.3", "12.3", "", "", "65.0", "53.0", "", "38.9", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1605, "brand_name": "Trianco", "model_name": "Centramatic", "model_qualifier": "55", "winter_efficiency_pct": 65.0, "summer_efficiency_pct": 53.0, "comparative_hot_water_efficiency_pct": 38.9, "output_kw_max": 16.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001605", "000062", "0", "2010/Sep/13 17:03", "Trianco Redfyre", "Trianco", "Centramatic", "55", "", "", "obsolete", "4", "0", "0", "1", "0", "", "", "1", "1", "1", "16.4", "16.4", "", "", "65.0", "53.0", "", "38.9", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1606, "brand_name": "Trianco", "model_name": "Centramatic", "model_qualifier": "80", "winter_efficiency_pct": 65.0, "summer_efficiency_pct": 53.0, "comparative_hot_water_efficiency_pct": 38.9, "output_kw_max": 23.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001606", "000062", "0", "2010/Sep/13 17:03", "Trianco Redfyre", "Trianco", "Centramatic", "80", "", "", "obsolete", "4", "0", "0", "1", "0", "", "", "1", "1", "1", "23.4", "23.4", "", "", "65.0", "53.0", "", "38.9", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1609, "brand_name": "Trianco", "model_name": "Centrajet", "model_qualifier": "18/28", "winter_efficiency_pct": 65.0, "summer_efficiency_pct": 53.0, "comparative_hot_water_efficiency_pct": 38.9, "output_kw_max": 28.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001609", "000062", "0", "2010/Sep/13 17:03", "Trianco Redfyre", "Trianco", "Centrajet", "18/28", "", "", "obsolete", "4", "0", "0", "1", "0", "", "", "1", "2", "2", "18", "28", "", "", "65.0", "53.0", "", "38.9", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1622, "brand_name": "Trisave", "model_name": "Fs", "model_qualifier": "43435", "winter_efficiency_pct": 91.0, "summer_efficiency_pct": 74.0, "comparative_hot_water_efficiency_pct": 53.7, "output_kw_max": 17.7, "final_year_of_manufacture": 1994, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001622", "000139", "0", "2010/Sep/13 17:03", "Trisave", "Trisave", "Fs", "43435", "4115902", "", "1994", "1", "0", "0", "1", "0", "", "", "2", "2", "2", "17.7", "17.7", "", "", "91.0", "74.0", "", "53.7", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0001", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1623, "brand_name": "Trisave", "model_name": "Fs", "model_qualifier": "18-24", "winter_efficiency_pct": 91.0, "summer_efficiency_pct": 74.0, "comparative_hot_water_efficiency_pct": 53.7, "output_kw_max": 23.3, "final_year_of_manufacture": 1991, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001623", "000139", "0", "2010/Sep/13 17:03", "Trisave", "Trisave", "Fs", "18-24", "4115901", "", "1991", "1", "0", "0", "1", "0", "", "", "2", "2", "2", "23.3", "23.3", "", "", "91.0", "74.0", "", "53.7", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0001", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1624, "brand_name": "Trisave", "model_name": "Fs", "model_qualifier": "60", "winter_efficiency_pct": 91.0, "summer_efficiency_pct": 74.0, "comparative_hot_water_efficiency_pct": 53.7, "output_kw_max": 17.6, "final_year_of_manufacture": 1991, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001624", "000139", "0", "2010/Sep/13 17:03", "Trisave", "Trisave", "Fs", "60", "4115905", "", "1991", "1", "0", "0", "1", "0", "", "", "2", "2", "2", "17.6", "17.6", "", "", "91.0", "74.0", "", "53.7", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0001", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1625, "brand_name": "Trisave", "model_name": "Fs", "model_qualifier": "80", "winter_efficiency_pct": 91.0, "summer_efficiency_pct": 74.0, "comparative_hot_water_efficiency_pct": 53.7, "output_kw_max": 24.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001625", "000139", "0", "2010/Sep/13 17:03", "Trisave", "Trisave", "Fs", "80", "4115912", "", "obsolete", "1", "0", "0", "1", "0", "", "", "2", "2", "2", "24.5", "24.5", "", "", "91.0", "74.0", "", "53.7", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0001", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1626, "brand_name": "Trisave", "model_name": "Turbo", "model_qualifier": "22", "winter_efficiency_pct": 91.0, "summer_efficiency_pct": 74.0, "comparative_hot_water_efficiency_pct": 53.7, "output_kw_max": 5.7, "final_year_of_manufacture": 1991, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001626", "000139", "0", "2010/Sep/13 17:03", "Trisave", "Trisave", "Turbo", "22", "4115906", "", "1991", "1", "0", "0", "1", "0", "", "", "2", "2", "2", "5.7", "5.7", "", "", "91.0", "74.0", "", "53.7", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0001", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1627, "brand_name": "Trisave", "model_name": "Turbo", "model_qualifier": "30", "winter_efficiency_pct": 91.0, "summer_efficiency_pct": 74.0, "comparative_hot_water_efficiency_pct": 53.7, "output_kw_max": 8.5, "final_year_of_manufacture": 1994, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001627", "000139", "0", "2010/Sep/13 17:03", "Trisave", "Trisave", "Turbo", "30", "4115907", "", "1994", "1", "0", "0", "1", "0", "", "", "2", "2", "2", "8.5", "8.5", "", "", "91.0", "74.0", "", "53.7", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0001", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1628, "brand_name": "Trisave", "model_name": "Turbo", "model_qualifier": "45", "winter_efficiency_pct": 91.0, "summer_efficiency_pct": 74.0, "comparative_hot_water_efficiency_pct": 53.7, "output_kw_max": 13.2, "final_year_of_manufacture": 1994, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001628", "000139", "0", "2010/Sep/13 17:03", "Trisave", "Trisave", "Turbo", "45", "4115903", "", "1994", "1", "0", "0", "1", "0", "", "", "2", "2", "2", "13.2", "13.2", "", "", "91.0", "74.0", "", "53.7", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0001", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1629, "brand_name": "Trisave", "model_name": "Turbo", "model_qualifier": "60", "winter_efficiency_pct": 91.0, "summer_efficiency_pct": 74.0, "comparative_hot_water_efficiency_pct": 53.7, "output_kw_max": 17.6, "final_year_of_manufacture": 1994, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001629", "000139", "0", "2010/Sep/13 17:03", "Trisave", "Trisave", "Turbo", "60", "4115904", "", "1994", "1", "0", "0", "1", "0", "", "", "2", "2", "2", "17.6", "17.6", "", "", "91.0", "74.0", "", "53.7", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0001", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1630, "brand_name": "Wickes", "model_name": "Wickes", "model_qualifier": "40bf", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 11.72, "final_year_of_manufacture": 1996, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001630", "000019", "0", "2010/Sep/13 17:03", "Wickes", "Wickes", "Wickes", "40bf", "4133322", "", "1996", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "11.72", "11.72", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1631, "brand_name": "Wickes", "model_name": "Wickes", "model_qualifier": "45f", "winter_efficiency_pct": 73.0, "summer_efficiency_pct": 63.0, "comparative_hot_water_efficiency_pct": 45.9, "output_kw_max": 13.19, "final_year_of_manufacture": 1997, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001631", "000019", "0", "2015/Jul/21 14:15", "Wickes", "Wickes", "Wickes", "45f", "4133311", "", "1997", "1", "0", "0", "1", "0", "", "", "1", "2", "2", "13.19", "13.19", "", "", "73.0", "63.0", "", "45.9", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1632, "brand_name": "Wickes", "model_name": "Wickes", "model_qualifier": "50bf", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 14.65, "final_year_of_manufacture": 1994, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001632", "000019", "0", "2010/Sep/13 17:03", "Wickes", "Wickes", "Wickes", "50bf", "4133323", "", "1994", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "14.65", "14.65", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1633, "brand_name": "Wickes", "model_name": "Wickes", "model_qualifier": "65f", "winter_efficiency_pct": 73.0, "summer_efficiency_pct": 63.0, "comparative_hot_water_efficiency_pct": 45.9, "output_kw_max": 19.05, "final_year_of_manufacture": 1997, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001633", "000019", "0", "2015/Jul/21 14:15", "Wickes", "Wickes", "Wickes", "65f", "4133312", "", "1997", "1", "0", "0", "1", "0", "", "", "1", "2", "2", "19.05", "19.05", "", "", "73.0", "63.0", "", "45.9", "", "3", "", "", "0", "1", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1634, "brand_name": "Wickes", "model_name": "Wickes", "model_qualifier": "combi", "winter_efficiency_pct": 71.0, "summer_efficiency_pct": 62.0, "comparative_hot_water_efficiency_pct": 43.2, "output_kw_max": 23.63, "final_year_of_manufacture": 1992, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001634", "000019", "0", "2010/Sep/13 17:03", "Wickes", "Wickes", "Wickes", "combi", "4770502", "", "1992", "1", "0", "0", "2", "0", "", "", "1", "2", "2", "23.63", "23.63", "", "", "71.0", "62.0", "", "43.2", "", "3", "", "", "0", "2", "0", "", "", "0", "", "0", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 1636, "brand_name": "Malvern", "model_name": "Combi", "model_qualifier": "NG", "winter_efficiency_pct": 84.6, "summer_efficiency_pct": 76.0, "comparative_hot_water_efficiency_pct": 53.5, "output_kw_max": 23.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001636", "000023", "0", "2006/Jan/17 12:31", "Malvern Boilers", "Malvern", "Combi", "NG", "GC No 47.555.02", "1995", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "23.5", "23.5", "", "", "84.6", "76.0", "", "53.5", "", "2", "", "", "104", "1", "2", "120", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "86.1", "89.0", "", "", "", "", "88.5"]} +{"pcdb_id": 1638, "brand_name": "Malvern", "model_name": "70/80", "model_qualifier": "NG", "winter_efficiency_pct": 82.9, "summer_efficiency_pct": 75.3, "comparative_hot_water_efficiency_pct": 55.0, "output_kw_max": 23.5, "final_year_of_manufacture": 2000, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001638", "000023", "0", "2012/Mar/27 10:12", "Malvern Boilers", "Malvern", "70/80", "NG", "GC No 41.555.10", "1995", "2000", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "20.6", "23.5", "", "", "82.9", "75.3", "", "55.0", "", "2", "", "", "101", "1", "1", "40", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "85.7", "88.7", "", "", "", "", "88.2"]} +{"pcdb_id": 1647, "brand_name": "Malvern", "model_name": "50", "model_qualifier": "NG", "winter_efficiency_pct": 83.2, "summer_efficiency_pct": 75.6, "comparative_hot_water_efficiency_pct": 55.2, "output_kw_max": 14.7, "final_year_of_manufacture": 2000, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001647", "000023", "0", "2012/Mar/27 10:12", "Malvern Boilers", "Malvern", "50", "NG", "GC No 41.555.01", "1993", "2000", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "14.7", "14.7", "", "", "83.2", "75.6", "", "55.2", "", "2", "", "", "101", "1", "1", "40", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "85.7", "89.5", "", "", "", "", "88.8"]} +{"pcdb_id": 1648, "brand_name": "Malvern", "model_name": "40", "model_qualifier": "NG", "winter_efficiency_pct": 82.6, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 11.7, "final_year_of_manufacture": 2000, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001648", "000023", "0", "2012/Mar/27 10:12", "Malvern Boilers", "Malvern", "40", "NG", "GC No 41.555.03", "1993", "2000", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "11.7", "11.7", "", "", "82.6", "75.0", "", "54.8", "", "2", "", "", "101", "1", "1", "40", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "85.0", "88.7", "", "", "", "", "88.0"]} +{"pcdb_id": 1649, "brand_name": "Malvern", "model_name": "30", "model_qualifier": "NG", "winter_efficiency_pct": 82.2, "summer_efficiency_pct": 74.6, "comparative_hot_water_efficiency_pct": 54.5, "output_kw_max": 8.8, "final_year_of_manufacture": 2000, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001649", "000023", "0", "2012/Mar/27 10:12", "Malvern Boilers", "Malvern", "30", "NG", "GC No 41.555.02", "1993", "2000", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "8.8", "8.8", "", "", "82.2", "74.6", "", "54.5", "", "2", "", "", "101", "1", "1", "40", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "84.2", "88.7", "", "", "", "", "87.9"]} +{"pcdb_id": 1650, "brand_name": "Alpha", "model_name": "280P", "model_qualifier": "", "winter_efficiency_pct": 75.8, "summer_efficiency_pct": 65.7, "comparative_hot_water_efficiency_pct": 46.2, "output_kw_max": 28.0, "final_year_of_manufacture": 2003, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001650", "000001", "0", "2006/Jan/17 12:55", "Alpha Therm", "Alpha", "280P", "", "", "1998", "2003", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "28", "28", "", "", "75.8", "65.7", "", "46.2", "", "2", "", "", "104", "2", "2", "170", "5", "0", "", "", "0", "0", "0", "", "0", "0", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.4", "80.5", "", "", "", "", "80.7"]} +{"pcdb_id": 1652, "brand_name": "Alpha", "model_name": "500E", "model_qualifier": "", "winter_efficiency_pct": 79.4, "summer_efficiency_pct": 70.3, "comparative_hot_water_efficiency_pct": 50.1, "output_kw_max": 28.0, "final_year_of_manufacture": 2003, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001652", "000001", "0", "2024/Jan/31 10:17", "Alpha Therm", "Alpha", "500E", "", "", "1996", "2003", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "28", "28", "", "", "79.4", "70.3", "", "50.1", "", "2", "", "", "106", "1", "2", "182", "5", "2", "2", "0", "54", "0", "50", "5", "65", "0.96", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.4", "79.1", "", "", "", "", "79.5"]} +{"pcdb_id": 1653, "brand_name": "Alpha", "model_name": "240X", "model_qualifier": "", "winter_efficiency_pct": 75.2, "summer_efficiency_pct": 65.1, "comparative_hot_water_efficiency_pct": 45.8, "output_kw_max": 23.3, "final_year_of_manufacture": 2003, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001653", "000001", "0", "2006/Jan/17 12:55", "Alpha Therm", "Alpha", "240X", "", "", "1998", "2003", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "23.3", "23.3", "", "", "75.2", "65.1", "", "45.8", "", "2", "", "", "104", "2", "2", "170", "20", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.7", "79.1", "", "", "", "", "79.6"]} +{"pcdb_id": 1658, "brand_name": "Keston", "model_name": "K", "model_qualifier": "50", "winter_efficiency_pct": 85.6, "summer_efficiency_pct": 78.0, "comparative_hot_water_efficiency_pct": 57.0, "output_kw_max": 15.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001658", "000022", "0", "2012/Mar/27 10:12", "Keston Boilers", "Keston", "K", "50", "Keston 50", "1994", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "14.1", "15.2", "", "", "85.6", "78.0", "", "57.0", "", "2", "", "", "101", "1", "1", "140", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "88.3", "94.1", "", "", "", "", "93.0"]} +{"pcdb_id": 1659, "brand_name": "Keston", "model_name": "K", "model_qualifier": "50P", "winter_efficiency_pct": 87.3, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 16.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001659", "000022", "0", "2012/Mar/27 10:12", "Keston Boilers", "Keston", "K", "50P", "Keston 50 LPG", "1994", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "14.5", "16.0", "", "", "87.3", "79.7", "", "58.2", "", "2", "0", "", "101", "1", "1", "140", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "88.4", "96.2", "", "", "", "", "94.7"]} +{"pcdb_id": 1660, "brand_name": "Keston", "model_name": "K", "model_qualifier": "60", "winter_efficiency_pct": 85.7, "summer_efficiency_pct": 78.1, "comparative_hot_water_efficiency_pct": 57.1, "output_kw_max": 17.7, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001660", "000022", "0", "2012/Mar/27 10:12", "Keston Boilers", "Keston", "K", "60", "Keston 60", "1994", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "16.2", "17.7", "", "", "85.7", "78.1", "", "57.1", "", "2", "", "", "101", "1", "1", "140", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "87.9", "94.6", "", "", "", "", "93.3"]} +{"pcdb_id": 1661, "brand_name": "Keston", "model_name": "K", "model_qualifier": "60P", "winter_efficiency_pct": 87.5, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 24.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001661", "000022", "0", "2012/Mar/27 10:12", "Keston Boilers", "Keston", "K", "60P", "Keston 60 LPG", "1994", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "22.6", "24.5", "", "", "87.5", "79.9", "", "58.3", "", "2", "0", "", "101", "1", "1", "175", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "88.2", "96.7", "", "", "", "", "95.1"]} +{"pcdb_id": 1662, "brand_name": "Keston", "model_name": "K", "model_qualifier": "80", "winter_efficiency_pct": 85.8, "summer_efficiency_pct": 78.2, "comparative_hot_water_efficiency_pct": 57.2, "output_kw_max": 23.7, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001662", "000022", "0", "2012/Mar/27 10:12", "Keston Boilers", "Keston", "K", "80", "Keston 80", "1994", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "21.4", "23.7", "", "", "85.8", "78.2", "", "57.2", "", "2", "", "", "101", "1", "1", "175", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "86.5", "95.5", "", "", "", "", "93.8"]} +{"pcdb_id": 1663, "brand_name": "Keston", "model_name": "K", "model_qualifier": "80P", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 80.6, "comparative_hot_water_efficiency_pct": 58.9, "output_kw_max": 24.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001663", "000022", "0", "2012/Mar/27 10:12", "Keston Boilers", "Keston", "K", "80P", "Keston 80 LPG", "1994", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "22.6", "24.5", "", "", "88.2", "80.6", "", "58.9", "", "2", "0", "", "101", "1", "1", "175", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.5", "97.6", "", "", "", "", "96.3"]} +{"pcdb_id": 1664, "brand_name": "Keston", "model_name": "K", "model_qualifier": "130", "winter_efficiency_pct": 86.3, "summer_efficiency_pct": 78.7, "comparative_hot_water_efficiency_pct": 57.5, "output_kw_max": 40.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001664", "000022", "0", "2012/Mar/27 10:12", "Keston Boilers", "Keston", "K", "130", "Keston 130", "1998", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "37.7", "40.5", "", "", "86.3", "78.7", "", "57.5", "", "2", "", "", "101", "1", "1", "500", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "89.6", "95.4", "", "", "", "", "94.3"]} +{"pcdb_id": 1665, "brand_name": "Keston", "model_name": "K", "model_qualifier": "130P", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 80.7, "comparative_hot_water_efficiency_pct": 59.0, "output_kw_max": 40.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001665", "000022", "0", "2012/Mar/27 10:12", "Keston Boilers", "Keston", "K", "130P", "Keston 130 LPG", "1998", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "37.7", "40.5", "", "", "88.3", "80.7", "", "59.0", "", "2", "0", "", "101", "1", "1", "500", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.6", "97.5", "", "", "", "", "96.4"]} +{"pcdb_id": 1666, "brand_name": "Keston", "model_name": "K", "model_qualifier": "170", "winter_efficiency_pct": 87.5, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 54.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001666", "000022", "0", "2012/Mar/27 10:12", "Keston Boilers", "Keston", "K", "170", "Keston 170", "1996", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "49.8", "54.5", "", "", "87.5", "79.9", "", "58.4", "", "2", "", "", "101", "1", "1", "500", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.6", "98.0", "", "", "", "", "96.6"]} +{"pcdb_id": 1667, "brand_name": "Keston", "model_name": "K", "model_qualifier": "170P", "winter_efficiency_pct": 89.5, "summer_efficiency_pct": 81.9, "comparative_hot_water_efficiency_pct": 59.8, "output_kw_max": 55.8, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001667", "000022", "0", "2012/Mar/27 10:12", "Keston Boilers", "Keston", "K", "170P", "Keston 170 LPG", "1996", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "51", "55.8", "", "", "89.5", "81.9", "", "59.8", "", "2", "0", "", "101", "1", "1", "500", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "92.7", "100.2", "", "", "", "", "98.8"]} +{"pcdb_id": 1670, "brand_name": "Yorkpark", "model_name": "Microstar", "model_qualifier": "THR 25", "winter_efficiency_pct": 87.5, "summer_efficiency_pct": 78.5, "comparative_hot_water_efficiency_pct": 57.3, "output_kw_max": 25.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001670", "000036", "0", "2012/Mar/27 10:12", "Yorkpark", "Yorkpark", "Microstar", "THR 25", "THR 5-25", "1997", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "25", "25", "", "", "87.5", "78.5", "", "57.3", "", "2", "", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "85.6", "96.9", "", "", "", "", "94.7"]} +{"pcdb_id": 1677, "brand_name": "Yorkpark", "model_name": "Microstar", "model_qualifier": "THR 50", "winter_efficiency_pct": 86.5, "summer_efficiency_pct": 77.5, "comparative_hot_water_efficiency_pct": 56.6, "output_kw_max": 50.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001677", "000036", "0", "2012/Mar/27 10:12", "Yorkpark", "Yorkpark", "Microstar", "THR 50", "THR 10-50", "1997", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "50", "50", "", "", "86.5", "77.5", "", "56.6", "", "2", "", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "84.7", "95.5", "", "", "", "", "93.5"]} +{"pcdb_id": 1681, "brand_name": "Yorkpark", "model_name": "Microstar", "model_qualifier": "25", "winter_efficiency_pct": 86.8, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 25.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001681", "000036", "0", "2012/Mar/27 10:12", "Yorkpark", "Yorkpark", "Microstar", "25", "MZ 11/18/25", "1993", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "11", "25", "", "", "86.8", "79.2", "", "57.8", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "88.1", "97.1", "", "", "", "", "95.4"]} +{"pcdb_id": 1683, "brand_name": "Yorkpark", "model_name": "Microstar", "model_qualifier": "25 Combi", "winter_efficiency_pct": 86.8, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 55.9, "output_kw_max": 25.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 1, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001683", "000036", "0", "1999/Sep/28 17:06", "Yorkpark", "Yorkpark", "Microstar", "25 Combi", "MZ 25 S", "1993", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "25", "25", "", "", "86.8", "79.6", "", "55.9", "", "2", "", "", "103", "1", "1", "", "", "1", "", "", "12.3", "0", "30", "2", "65", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "88.1", "97.1", "", "", "", "", "95.4"]} +{"pcdb_id": 1687, "brand_name": "Yorkpark", "model_name": "Yorkstar", "model_qualifier": "20", "winter_efficiency_pct": 86.1, "summer_efficiency_pct": 78.3, "comparative_hot_water_efficiency_pct": 57.2, "output_kw_max": 24.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001687", "000036", "0", "2012/Mar/27 10:12", "Yorkpark", "Yorkpark", "Yorkstar", "20", "FCX 20", "1990", "current", "4", "1", "1", "1", "0", "", "", "2", "2", "2", "20", "24", "", "", "86.1", "78.3", "", "57.2", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "87.8", "92.6", "", "", "", "", "91.7"]} +{"pcdb_id": 1691, "brand_name": "Yorkpark", "model_name": "Microstar", "model_qualifier": "40", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 40.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001691", "000036", "0", "2012/Mar/27 10:12", "Yorkpark", "Yorkpark", "Microstar", "40", "MZ 20/40", "1992", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "40", "40", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "96.9", "", "", "", "", "95.2"]} +{"pcdb_id": 1692, "brand_name": "Alpha", "model_name": "280E", "model_qualifier": "Alpha Combimax 600", "winter_efficiency_pct": 80.1, "summer_efficiency_pct": 71.0, "comparative_hot_water_efficiency_pct": 36.6, "output_kw_max": 28.0, "final_year_of_manufacture": 2003, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001692", "000001", "0", "2024/Jan/31 10:17", "Alpha Therm", "Alpha", "280E", "Alpha Combimax 600", "", "1998", "2003", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "28", "28", "", "", "80.1", "71.0", "", "36.6", "", "2", "", "", "106", "1", "2", "260", "5", "2", "1", "0", "60", "0", "15", "2", "56", "0.8", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.4", "80.5", "", "", "", "", "80.7"]} +{"pcdb_id": 1693, "brand_name": "Alpha", "model_name": "240E", "model_qualifier": "", "winter_efficiency_pct": 79.2, "summer_efficiency_pct": 69.1, "comparative_hot_water_efficiency_pct": 48.6, "output_kw_max": 23.3, "final_year_of_manufacture": 2003, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001693", "000001", "0", "2006/Jan/17 12:55", "Alpha Therm", "Alpha", "240E", "", "", "1995", "2003", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "23.3", "23.3", "", "", "79.2", "69.1", "", "48.6", "", "2", "", "", "104", "1", "2", "170", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.7", "79.1", "", "", "", "", "79.6"]} +{"pcdb_id": 1694, "brand_name": "Alpha", "model_name": "240E", "model_qualifier": "Alpha Combimax 350", "winter_efficiency_pct": 79.5, "summer_efficiency_pct": 70.4, "comparative_hot_water_efficiency_pct": 38.4, "output_kw_max": 23.3, "final_year_of_manufacture": 2003, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001694", "000001", "0", "2024/Jan/31 10:17", "Alpha Therm", "Alpha", "240E", "Alpha Combimax 350", "", "1998", "2003", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "23.3", "23.3", "", "", "79.5", "70.4", "", "38.4", "", "2", "", "", "106", "1", "2", "260", "5", "2", "1", "0", "35", "0", "15", "2", "56", "0.97", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.7", "79.1", "", "", "", "", "79.6"]} +{"pcdb_id": 1695, "brand_name": "Alpha", "model_name": "280E", "model_qualifier": "", "winter_efficiency_pct": 79.8, "summer_efficiency_pct": 69.7, "comparative_hot_water_efficiency_pct": 49.0, "output_kw_max": 28.0, "final_year_of_manufacture": 2003, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001695", "000001", "0", "2006/Jan/17 12:55", "Alpha Therm", "Alpha", "280E", "", "", "1996", "2003", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "28", "28", "", "", "79.8", "69.7", "", "49.0", "", "2", "", "", "104", "1", "2", "170", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.4", "80.5", "", "", "", "", "80.7"]} +{"pcdb_id": 1707, "brand_name": "Worcester", "model_name": "24 Sbi", "model_qualifier": "RSF", "winter_efficiency_pct": 79.2, "summer_efficiency_pct": 69.1, "comparative_hot_water_efficiency_pct": 50.5, "output_kw_max": 24.0, "final_year_of_manufacture": 2005, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001707", "000035", "0", "2020/Sep/02 14:03", "Worcester Heat Systems", "Worcester", "24 Sbi", "RSF", "41 311 44", "1999", "2005", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "15", "24", "", "", "79.2", "69.1", "", "50.5", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.5", "79.0", "", "", "", "", "79.7"]} +{"pcdb_id": 1709, "brand_name": "Worcester", "model_name": "High Flow 400", "model_qualifier": "BF", "winter_efficiency_pct": 79.7, "summer_efficiency_pct": 71.8, "comparative_hot_water_efficiency_pct": 37.0, "output_kw_max": 24.0, "final_year_of_manufacture": 2002, "subsidiary_type": 0, "store_type": 1, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001709", "000035", "0", "2024/Jan/31 10:17", "Worcester Heat Systems", "Worcester", "High Flow 400", "BF", "47 311 19", "1997", "2002", "1", "1", "1", "2", "0", "", "", "1", "2", "1", "8.8", "24", "", "", "79.7", "71.8", "", "37.0", "", "2", "", "", "105", "2", "1", "", "", "1", "2", "0", "65", "0", "25", "3", "70", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.8", "88.7", "", "", "", "", "88.5"]} +{"pcdb_id": 1711, "brand_name": "British Gas/Scottish Gas", "model_name": "C1", "model_qualifier": "RSF", "winter_efficiency_pct": 79.1, "summer_efficiency_pct": 69.0, "comparative_hot_water_efficiency_pct": 48.5, "output_kw_max": 28.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001711", "000035", "0", "2002/Aug/14 10:22", "Worcester Heat Systems", "British Gas/Scottish Gas", "C1", "RSF", "47 311 51", "1999", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "28", "28", "", "", "79.1", "69.0", "", "48.5", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "84.0", "77.7", "", "", "", "", "78.9"]} +{"pcdb_id": 1712, "brand_name": "Worcester", "model_name": "Highflow 400", "model_qualifier": "OF", "winter_efficiency_pct": 79.2, "summer_efficiency_pct": 69.9, "comparative_hot_water_efficiency_pct": 49.1, "output_kw_max": 24.0, "final_year_of_manufacture": 2002, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001712", "000035", "0", "2002/Jan/09 12:33", "Worcester Heat Systems", "Worcester", "Highflow 400", "OF", "47 311 20", "1997", "2002", "1", "1", "1", "2", "0", "", "", "1", "1", "1", "8.8", "24", "", "", "79.2", "69.9", "", "49.1", "", "2", "", "", "103", "2", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.0", "88.7", "", "", "", "", "87.4"]} +{"pcdb_id": 1713, "brand_name": "Worcester", "model_name": "Highflow 400", "model_qualifier": "RSF", "winter_efficiency_pct": 79.9, "summer_efficiency_pct": 72.0, "comparative_hot_water_efficiency_pct": 37.1, "output_kw_max": 24.0, "final_year_of_manufacture": 2002, "subsidiary_type": 0, "store_type": 1, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001713", "000035", "0", "2024/Jan/31 10:17", "Worcester Heat Systems", "Worcester", "Highflow 400", "RSF", "47 311 18", "1997", "2002", "1", "1", "1", "2", "0", "", "", "1", "2", "2", "8.8", "24", "", "", "79.9", "72.0", "", "37.1", "", "2", "", "", "105", "1", "1", "", "", "1", "2", "0", "65", "0", "25", "3", "70", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.1", "81.5", "", "", "", "", "81.6"]} +{"pcdb_id": 1716, "brand_name": "Worcester", "model_name": "15 Sbi", "model_qualifier": "RSF", "winter_efficiency_pct": 80.8, "summer_efficiency_pct": 70.7, "comparative_hot_water_efficiency_pct": 51.6, "output_kw_max": 15.0, "final_year_of_manufacture": 2005, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001716", "000035", "0", "2020/Sep/02 14:04", "Worcester Heat Systems", "Worcester", "15 Sbi", "RSF", "41 311 43", "1999", "2005", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "6", "15", "", "", "80.8", "70.7", "", "51.6", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.2", "83.5", "", "", "", "", "83.1"]} +{"pcdb_id": 1717, "brand_name": "Servowarm", "model_name": "Elite HE 30", "model_qualifier": "", "winter_efficiency_pct": 82.2, "summer_efficiency_pct": 74.6, "comparative_hot_water_efficiency_pct": 54.5, "output_kw_max": 8.8, "final_year_of_manufacture": 2000, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001717", "000091", "0", "2012/Mar/27 10:12", "Malvern Boilers", "Servowarm", "Elite HE 30", "", "GC No 47.555.07", "1993", "2000", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "8.8", "8.8", "", "", "82.2", "74.6", "", "54.5", "", "2", "", "", "101", "1", "1", "40", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "84.2", "88.7", "", "", "", "", "87.9"]} +{"pcdb_id": 1718, "brand_name": "Servowarm", "model_name": "Elite HE 70/80", "model_qualifier": "", "winter_efficiency_pct": 82.9, "summer_efficiency_pct": 75.3, "comparative_hot_water_efficiency_pct": 55.0, "output_kw_max": 23.5, "final_year_of_manufacture": 2000, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001718", "000091", "0", "2012/Mar/27 10:12", "Malvern Boilers", "Servowarm", "Elite HE 70/80", "", "GC No 47.555.12", "1995", "2000", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "20.6", "23.5", "", "", "82.9", "75.3", "", "55.0", "", "2", "", "", "101", "1", "1", "40", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "85.7", "88.7", "", "", "", "", "88.2"]} +{"pcdb_id": 1719, "brand_name": "Servowarm", "model_name": "Elite HE Combi", "model_qualifier": "", "winter_efficiency_pct": 84.6, "summer_efficiency_pct": 76.0, "comparative_hot_water_efficiency_pct": 53.5, "output_kw_max": 23.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001719", "000091", "0", "2006/Jan/17 12:31", "Malvern Boilers", "Servowarm", "Elite HE Combi", "", "GC No 47.555.04", "1995", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "23.5", "23.5", "", "", "84.6", "76.0", "", "53.5", "", "2", "", "", "104", "1", "2", "120", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "86.1", "89.0", "", "", "", "", "88.5"]} +{"pcdb_id": 1720, "brand_name": "Servowarm", "model_name": "Elite HE 50", "model_qualifier": "", "winter_efficiency_pct": 83.2, "summer_efficiency_pct": 75.6, "comparative_hot_water_efficiency_pct": 55.2, "output_kw_max": 14.7, "final_year_of_manufacture": 2000, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001720", "000091", "0", "2012/Mar/27 10:12", "Malvern Boilers", "Servowarm", "Elite HE 50", "", "GC No 47.555.09", "1993", "2000", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "14.7", "14.7", "", "", "83.2", "75.6", "", "55.2", "", "2", "", "", "101", "1", "1", "40", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "85.7", "89.5", "", "", "", "", "88.8"]} +{"pcdb_id": 1721, "brand_name": "Servowarm", "model_name": "Elite HE 40", "model_qualifier": "", "winter_efficiency_pct": 82.6, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 11.7, "final_year_of_manufacture": 2000, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001721", "000091", "0", "2012/Mar/27 10:12", "Malvern Boilers", "Servowarm", "Elite HE 40", "", "GC No 47.555.08", "1993", "2000", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "11.7", "11.7", "", "", "82.6", "75.0", "", "54.8", "", "2", "", "", "101", "1", "1", "40", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "85.0", "88.7", "", "", "", "", "88.0"]} +{"pcdb_id": 1722, "brand_name": "Warmworld", "model_name": "Warmworld HE 30", "model_qualifier": "", "winter_efficiency_pct": 82.2, "summer_efficiency_pct": 74.6, "comparative_hot_water_efficiency_pct": 54.5, "output_kw_max": 8.8, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001722", "000034", "0", "2012/Mar/27 10:12", "Warmworld", "Warmworld", "Warmworld HE 30", "", "GC No 41.555.04", "1993", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "8.8", "8.8", "", "", "82.2", "74.6", "", "54.5", "", "2", "", "", "101", "1", "1", "40", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "84.2", "88.7", "", "", "", "", "87.9"]} +{"pcdb_id": 1723, "brand_name": "Warmworld", "model_name": "Warmworld HE 40", "model_qualifier": "", "winter_efficiency_pct": 82.6, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 11.7, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001723", "000034", "0", "2012/Mar/27 10:12", "Warmworld", "Warmworld", "Warmworld HE 40", "", "GC No 41.555.05", "1993", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "11.7", "11.7", "", "", "82.6", "75.0", "", "54.8", "", "2", "", "", "101", "1", "1", "40", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "85.0", "88.7", "", "", "", "", "88.0"]} +{"pcdb_id": 1724, "brand_name": "Warmworld", "model_name": "Warmworld HE 50", "model_qualifier": "", "winter_efficiency_pct": 83.2, "summer_efficiency_pct": 75.6, "comparative_hot_water_efficiency_pct": 55.2, "output_kw_max": 14.7, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001724", "000034", "0", "2012/Mar/27 10:12", "Warmworld", "Warmworld", "Warmworld HE 50", "", "GC No 41.555.06", "1993", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "14.7", "14.7", "", "", "83.2", "75.6", "", "55.2", "", "2", "", "", "101", "1", "1", "40", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "85.7", "89.5", "", "", "", "", "88.8"]} +{"pcdb_id": 1725, "brand_name": "Warmworld", "model_name": "Warmworld HE 70/80", "model_qualifier": "", "winter_efficiency_pct": 82.9, "summer_efficiency_pct": 75.3, "comparative_hot_water_efficiency_pct": 55.0, "output_kw_max": 23.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001725", "000034", "0", "2012/Mar/27 10:12", "Warmworld", "Warmworld", "Warmworld HE 70/80", "", "GC No 41.555.11", "1995", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "20.6", "23.5", "", "", "82.9", "75.3", "", "55.0", "", "2", "", "", "101", "1", "1", "40", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "85.7", "88.7", "", "", "", "", "88.2"]} +{"pcdb_id": 1726, "brand_name": "Warmworld", "model_name": "Warmworld Combi", "model_qualifier": "", "winter_efficiency_pct": 84.6, "summer_efficiency_pct": 76.0, "comparative_hot_water_efficiency_pct": 53.5, "output_kw_max": 23.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001726", "000034", "0", "2006/Jan/31 12:06", "Warmworld", "Warmworld", "Warmworld Combi", "", "GC No 47.555.03", "1995", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "23.5", "23.5", "", "", "84.6", "76.0", "", "53.5", "", "2", "", "", "104", "1", "2", "120", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "86.1", "89.0", "", "", "", "", "88.5"]} +{"pcdb_id": 1727, "brand_name": "Worcester", "model_name": "35 Cdi", "model_qualifier": "RSF", "winter_efficiency_pct": 79.8, "summer_efficiency_pct": 69.7, "comparative_hot_water_efficiency_pct": 49.0, "output_kw_max": 25.0, "final_year_of_manufacture": 2002, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001727", "000035", "0", "2002/Sep/27 13:16", "Worcester Heat Systems", "Worcester", "35 Cdi", "RSF", "47 311 39", "1998", "2002", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "25", "25", "", "", "79.8", "69.7", "", "49.0", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.7", "79.4", "", "", "", "", "80.0"]} +{"pcdb_id": 1730, "brand_name": "Worcester", "model_name": "24 I", "model_qualifier": "RSF", "winter_efficiency_pct": 77.0, "summer_efficiency_pct": 66.9, "comparative_hot_water_efficiency_pct": 47.1, "output_kw_max": 23.4, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001730", "000035", "0", "2001/Nov/22 08:42", "Worcester Heat Systems", "Worcester", "24 I", "RSF", "47 311 37", "1998", "2001", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "23.4", "23.4", "", "", "77.0", "66.9", "", "47.1", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "79.7", "76.7", "", "", "", "", "77.3"]} +{"pcdb_id": 1731, "brand_name": "Worcester", "model_name": "Bosch Greenstar ZWBR", "model_qualifier": "7-25A", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 56.4, "output_kw_max": 25.3, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001731", "000035", "0", "2003/May/29 14:12", "Worcester Heat Systems", "Worcester", "Bosch Greenstar ZWBR", "7-25A", "47 311 44", "1999", "2001", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "25.3", "25.3", "", "", "88.8", "80.2", "", "56.4", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.2", "98.2", "", "", "", "", "96.5"]} +{"pcdb_id": 1733, "brand_name": "Worcester", "model_name": "80 ic", "model_qualifier": "RSF", "winter_efficiency_pct": 76.1, "summer_efficiency_pct": 66.0, "comparative_hot_water_efficiency_pct": 46.4, "output_kw_max": 20.0, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001733", "000035", "0", "2006/Jan/17 12:55", "Worcester Heat Systems", "Worcester", "80 ic", "RSF", "", "1999", "2001", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "20", "20", "", "", "76.1", "66.0", "", "46.4", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.0", "73.5", "", "", "", "", "74.9"]} +{"pcdb_id": 1736, "brand_name": "Worcester", "model_name": "Heat Slave", "model_qualifier": "15/19.OSO", "winter_efficiency_pct": 84.6, "summer_efficiency_pct": 76.5, "comparative_hot_water_efficiency_pct": 41.5, "output_kw_max": 19.0, "final_year_of_manufacture": 2008, "subsidiary_type": 0, "store_type": 1, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001736", "000035", "0", "2024/Jan/31 10:17", "Worcester Heat Systems", "Worcester", "Heat Slave", "15/19.OSO", "C14769/3-1", "1997", "2008", "4", "1", "1", "2", "0", "", "", "1", "1", "2", "19", "19", "", "", "84.6", "76.5", "", "41.5", "", "2", "", "", "203", "1", "2", "", "", "1", "2", "0", "46", "0", "25", "3", "70", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "85.6", "87.9", "", "", "", "", "87.5"]} +{"pcdb_id": 1737, "brand_name": "Worcester", "model_name": "Heat Slave", "model_qualifier": "12/14.OSO", "winter_efficiency_pct": 83.7, "summer_efficiency_pct": 75.6, "comparative_hot_water_efficiency_pct": 41.0, "output_kw_max": 14.0, "final_year_of_manufacture": 2002, "subsidiary_type": 0, "store_type": 1, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001737", "000035", "0", "2024/Jan/31 10:17", "Worcester Heat Systems", "Worcester", "Heat Slave", "12/14.OSO", "C14769/2-1", "1997", "2002", "4", "1", "1", "2", "0", "", "", "1", "1", "2", "12", "14", "", "", "83.7", "75.6", "", "41.0", "", "2", "", "", "203", "1", "1", "", "", "1", "2", "0", "46", "0", "25", "3", "70", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "83.7", "88.9", "", "", "", "", "87.9"]} +{"pcdb_id": 1738, "brand_name": "Worcester", "model_name": "Heat Slave", "model_qualifier": "12/14.RSO", "winter_efficiency_pct": 83.7, "summer_efficiency_pct": 75.6, "comparative_hot_water_efficiency_pct": 41.0, "output_kw_max": 14.0, "final_year_of_manufacture": 2002, "subsidiary_type": 0, "store_type": 1, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001738", "000035", "0", "2024/Jan/31 10:17", "Worcester Heat Systems", "Worcester", "Heat Slave", "12/14.RSO", "C14769/2-1", "1997", "2002", "4", "1", "1", "2", "0", "", "", "1", "1", "2", "12", "14", "", "", "83.7", "75.6", "", "41.0", "", "2", "", "", "203", "1", "1", "", "", "1", "2", "0", "46", "0", "25", "3", "70", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "83.7", "88.9", "", "", "", "", "87.9"]} +{"pcdb_id": 1739, "brand_name": "Worcester", "model_name": "Heat Slave", "model_qualifier": "15/19.RSO", "winter_efficiency_pct": 84.6, "summer_efficiency_pct": 76.5, "comparative_hot_water_efficiency_pct": 41.5, "output_kw_max": 19.0, "final_year_of_manufacture": 2008, "subsidiary_type": 0, "store_type": 1, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001739", "000035", "0", "2024/Jan/31 10:17", "Worcester Heat Systems", "Worcester", "Heat Slave", "15/19.RSO", "C14769/4-1", "1997", "2008", "4", "1", "1", "2", "0", "", "", "1", "1", "2", "19", "19", "", "", "84.6", "76.5", "", "41.5", "", "2", "", "", "203", "1", "2", "", "", "1", "2", "0", "46", "0", "25", "3", "70", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "85.6", "87.9", "", "", "", "", "87.5"]} +{"pcdb_id": 1740, "brand_name": "Worcester", "model_name": "Heat Slave", "model_qualifier": "20/25.RSO", "winter_efficiency_pct": 84.6, "summer_efficiency_pct": 76.5, "comparative_hot_water_efficiency_pct": 41.5, "output_kw_max": 20.0, "final_year_of_manufacture": 2002, "subsidiary_type": 0, "store_type": 1, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001740", "000035", "0", "2024/Jan/31 10:17", "Worcester Heat Systems", "Worcester", "Heat Slave", "20/25.RSO", "C14769/3-1", "1997", "2002", "4", "1", "1", "2", "0", "", "", "1", "1", "2", "20", "20", "", "", "84.6", "76.5", "", "41.5", "", "2", "", "", "203", "1", "2", "", "", "1", "2", "0", "46", "0", "25", "3", "70", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "85.6", "87.9", "", "", "", "", "87.5"]} +{"pcdb_id": 1741, "brand_name": "Worcester", "model_name": "Heat Slave", "model_qualifier": "20/25.OSO", "winter_efficiency_pct": 83.3, "summer_efficiency_pct": 75.2, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 25.0, "final_year_of_manufacture": 2002, "subsidiary_type": 0, "store_type": 1, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001741", "000035", "0", "2024/Jan/31 10:17", "Worcester Heat Systems", "Worcester", "Heat Slave", "20/25.OSO", "C14769/4-1", "1997", "2002", "4", "1", "1", "2", "0", "", "", "1", "1", "2", "20", "25", "", "", "83.3", "75.2", "", "40.8", "", "2", "", "", "203", "1", "1", "", "", "1", "2", "0", "46", "0", "25", "3", "70", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "83.3", "86.8", "", "", "", "", "86.1"]} +{"pcdb_id": 1742, "brand_name": "Worcester", "model_name": "Danesmoor", "model_qualifier": "32/50.000", "winter_efficiency_pct": 84.2, "summer_efficiency_pct": 72.5, "comparative_hot_water_efficiency_pct": 53.0, "output_kw_max": 50.0, "final_year_of_manufacture": 2002, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001742", "000035", "0", "2012/Mar/27 10:12", "Worcester Heat Systems", "Worcester", "Danesmoor", "32/50.000", "C14769/6-1", "1995", "2002", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "32", "50", "", "", "84.2", "72.5", "", "53.0", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "84.0", "84.4", "", "", "", "", "84.3"]} +{"pcdb_id": 1743, "brand_name": "Worcester", "model_name": "Danesmoor", "model_qualifier": "50/70.000", "winter_efficiency_pct": 85.7, "summer_efficiency_pct": 74.0, "comparative_hot_water_efficiency_pct": 54.0, "output_kw_max": 70.0, "final_year_of_manufacture": 2002, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001743", "000035", "0", "2020/Sep/02 14:06", "Worcester Heat Systems", "Worcester", "Danesmoor", "50/70.000", "C14769/7-1", "1995", "2002", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "50", "70", "", "", "85.7", "74.0", "", "54.0", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "84.2", "87.8", "", "", "", "", "87.1"]} +{"pcdb_id": 1744, "brand_name": "Worcester", "model_name": "Danesmoor System", "model_qualifier": "15.19.OSO", "winter_efficiency_pct": 86.4, "summer_efficiency_pct": 74.7, "comparative_hot_water_efficiency_pct": 54.6, "output_kw_max": 19.0, "final_year_of_manufacture": 2008, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001744", "000035", "0", "2020/Sep/02 14:10", "Worcester Heat Systems", "Worcester", "Danesmoor System", "15.19.OSO", "C14769/3-1", "1995", "2008", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "15", "19", "", "", "86.4", "74.7", "", "54.6", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.6", "87.9", "", "", "", "", "87.5"]} +{"pcdb_id": 1746, "brand_name": "Worcester", "model_name": "24 Cdi", "model_qualifier": "OF", "winter_efficiency_pct": 77.1, "summer_efficiency_pct": 67.0, "comparative_hot_water_efficiency_pct": 47.1, "output_kw_max": 24.0, "final_year_of_manufacture": 2002, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001746", "000035", "0", "2002/Feb/21 14:21", "Worcester Heat Systems", "Worcester", "24 Cdi", "OF", "47 311 32", "1997", "2002", "1", "2", "1", "2", "0", "", "", "1", "1", "1", "24.0", "24.0", "", "", "77.1", "67.0", "", "47.1", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "80.1", "76.4", "", "", "", "", "77.1"]} +{"pcdb_id": 1747, "brand_name": "Worcester", "model_name": "24 Cdi", "model_qualifier": "BF", "winter_efficiency_pct": 80.3, "summer_efficiency_pct": 70.2, "comparative_hot_water_efficiency_pct": 49.4, "output_kw_max": 24.0, "final_year_of_manufacture": 2005, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001747", "000035", "0", "2020/Sep/02 14:10", "Worcester Heat Systems", "Worcester", "24 Cdi", "BF", "47 311 29", "1997", "2005", "1", "2", "1", "2", "0", "", "", "1", "2", "1", "24", "24", "", "", "80.3", "70.2", "", "49.4", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.2", "80.8", "", "", "", "", "81.1"]} +{"pcdb_id": 1749, "brand_name": "Worcester", "model_name": "24 Cdi", "model_qualifier": "RSF", "winter_efficiency_pct": 76.9, "summer_efficiency_pct": 66.8, "comparative_hot_water_efficiency_pct": 47.0, "output_kw_max": 24.0, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001749", "000035", "0", "2006/Jan/17 12:55", "Worcester Heat Systems", "Worcester", "24 Cdi", "RSF", "47 311 30", "1997", "2001", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "24.0", "24.0", "", "", "76.9", "66.8", "", "47.0", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "79.8", "76.3", "", "", "", "", "77.0"]} +{"pcdb_id": 1750, "brand_name": "Worcester", "model_name": "24 LE", "model_qualifier": "RSF", "winter_efficiency_pct": 76.9, "summer_efficiency_pct": 66.8, "comparative_hot_water_efficiency_pct": 47.0, "output_kw_max": 24.0, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001750", "000035", "0", "2001/Nov/22 08:43", "Worcester Heat Systems", "Worcester", "24 LE", "RSF", "47 311 30", "1998", "2001", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "24", "24", "", "", "76.9", "66.8", "", "47.0", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "79.8", "76.3", "", "", "", "", "77.0"]} +{"pcdb_id": 1752, "brand_name": "Worcester", "model_name": "Bosch", "model_qualifier": "90/110.000", "winter_efficiency_pct": 86.2, "summer_efficiency_pct": 74.5, "comparative_hot_water_efficiency_pct": 54.4, "output_kw_max": 32.0, "final_year_of_manufacture": 2008, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001752", "000035", "0", "2020/Sep/02 14:10", "Worcester Heat Systems", "Worcester", "Bosch", "90/110.000", "C14769/5-1", "1997", "2008", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "26", "32", "", "", "86.2", "74.5", "", "54.4", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.3", "88.1", "", "", "", "", "87.5"]} +{"pcdb_id": 1753, "brand_name": "Worcester", "model_name": "Bosch", "model_qualifier": "70/90.000", "winter_efficiency_pct": 85.0, "summer_efficiency_pct": 73.3, "comparative_hot_water_efficiency_pct": 53.6, "output_kw_max": 25.0, "final_year_of_manufacture": 2002, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001753", "000035", "0", "2020/Sep/02 14:10", "Worcester Heat Systems", "Worcester", "Bosch", "70/90.000", "C14769/4-1", "1997", "2002", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "20", "25", "", "", "85.0", "73.3", "", "53.6", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "83.3", "86.8", "", "", "", "", "86.1"]} +{"pcdb_id": 1754, "brand_name": "Worcester", "model_name": "Bosch", "model_qualifier": "50/70.000", "winter_efficiency_pct": 86.4, "summer_efficiency_pct": 74.7, "comparative_hot_water_efficiency_pct": 54.6, "output_kw_max": 19.0, "final_year_of_manufacture": 2008, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001754", "000035", "0", "2020/Sep/02 14:11", "Worcester Heat Systems", "Worcester", "Bosch", "50/70.000", "C14769/3-1", "1997", "2008", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "15", "19", "", "", "86.4", "74.7", "", "54.6", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.6", "87.9", "", "", "", "", "87.5"]} +{"pcdb_id": 1756, "brand_name": "Worcester", "model_name": "28 LE", "model_qualifier": "RSF", "winter_efficiency_pct": 79.8, "summer_efficiency_pct": 69.7, "comparative_hot_water_efficiency_pct": 49.0, "output_kw_max": 24.0, "final_year_of_manufacture": 2005, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001756", "000035", "0", "2020/Sep/02 14:11", "Worcester Heat Systems", "Worcester", "28 LE", "RSF", "47 311 34", "1998", "2005", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "24", "24", "", "", "79.8", "69.7", "", "49.0", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.2", "79.7", "", "", "", "", "80.2"]} +{"pcdb_id": 1758, "brand_name": "Worcester", "model_name": "28 Cdi", "model_qualifier": "RSF", "winter_efficiency_pct": 79.8, "summer_efficiency_pct": 69.7, "comparative_hot_water_efficiency_pct": 49.0, "output_kw_max": 24.0, "final_year_of_manufacture": 2005, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001758", "000035", "0", "2020/Sep/02 14:11", "Worcester Heat Systems", "Worcester", "28 Cdi", "RSF", "47 311 34", "1997", "2005", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "24", "24", "", "", "79.8", "69.7", "", "49.0", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.2", "79.7", "", "", "", "", "80.2"]} +{"pcdb_id": 1760, "brand_name": "Worcester", "model_name": "26 Cdi", "model_qualifier": "Xtra", "winter_efficiency_pct": 84.8, "summer_efficiency_pct": 76.2, "comparative_hot_water_efficiency_pct": 53.6, "output_kw_max": 26.0, "final_year_of_manufacture": 2002, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001760", "000035", "0", "2002/Aug/14 10:24", "Worcester Heat Systems", "Worcester", "26 Cdi", "Xtra", "47 311 41", "1998", "2002", "1", "2", "2", "2", "0", "", "", "2", "2", "2", "26", "26", "", "", "84.8", "76.2", "", "53.6", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "85.6", "90.1", "", "", "", "", "89.2"]} +{"pcdb_id": 1761, "brand_name": "Worcester", "model_name": "Danesmoor System", "model_qualifier": "12/14.RSO", "winter_efficiency_pct": 85.4, "summer_efficiency_pct": 73.7, "comparative_hot_water_efficiency_pct": 53.8, "output_kw_max": 14.0, "final_year_of_manufacture": 2002, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001761", "000035", "0", "2020/Sep/02 14:11", "Worcester Heat Systems", "Worcester", "Danesmoor System", "12/14.RSO", "C14769/2-1", "1995", "2002", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "12", "14", "", "", "85.4", "73.7", "", "53.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "83.7", "88.9", "", "", "", "", "87.9"]} +{"pcdb_id": 1762, "brand_name": "Worcester", "model_name": "Danesmoor System", "model_qualifier": "12/14.OSO", "winter_efficiency_pct": 85.4, "summer_efficiency_pct": 73.7, "comparative_hot_water_efficiency_pct": 53.8, "output_kw_max": 14.0, "final_year_of_manufacture": 2002, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001762", "000035", "0", "2020/Sep/02 14:11", "Worcester Heat Systems", "Worcester", "Danesmoor System", "12/14.OSO", "C14769/2-1", "1995", "2002", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "12", "14", "", "", "85.4", "73.7", "", "53.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "83.7", "88.9", "", "", "", "", "87.9"]} +{"pcdb_id": 1763, "brand_name": "Worcester", "model_name": "Danesmoor System", "model_qualifier": "15/19.RSO", "winter_efficiency_pct": 86.4, "summer_efficiency_pct": 74.7, "comparative_hot_water_efficiency_pct": 54.6, "output_kw_max": 19.0, "final_year_of_manufacture": 2008, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001763", "000035", "0", "2020/Sep/02 14:11", "Worcester Heat Systems", "Worcester", "Danesmoor System", "15/19.RSO", "C14769/3-1", "1995", "2008", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "15", "19", "", "", "86.4", "74.7", "", "54.6", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.6", "87.9", "", "", "", "", "87.5"]} +{"pcdb_id": 1764, "brand_name": "Worcester", "model_name": "Danesmoor System", "model_qualifier": "20/25.RSO", "winter_efficiency_pct": 85.0, "summer_efficiency_pct": 73.3, "comparative_hot_water_efficiency_pct": 53.6, "output_kw_max": 25.0, "final_year_of_manufacture": 2002, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001764", "000035", "0", "2020/Sep/02 14:11", "Worcester Heat Systems", "Worcester", "Danesmoor System", "20/25.RSO", "C14769/4-1", "1995", "2002", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "20", "25", "", "", "85.0", "73.3", "", "53.6", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "83.3", "86.8", "", "", "", "", "86.1"]} +{"pcdb_id": 1765, "brand_name": "Worcester", "model_name": "Danesmoor System", "model_qualifier": "20/25.OSO", "winter_efficiency_pct": 85.0, "summer_efficiency_pct": 73.3, "comparative_hot_water_efficiency_pct": 53.6, "output_kw_max": 25.0, "final_year_of_manufacture": 2002, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001765", "000035", "0", "2020/Sep/02 14:12", "Worcester Heat Systems", "Worcester", "Danesmoor System", "20/25.OSO", "C14769/4-1", "1995", "2002", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "20", "25", "", "", "85.0", "73.3", "", "53.6", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "83.3", "86.8", "", "", "", "", "86.1"]} +{"pcdb_id": 1766, "brand_name": "Worcester", "model_name": "Danesmoor", "model_qualifier": "12/14.ROO", "winter_efficiency_pct": 85.4, "summer_efficiency_pct": 73.7, "comparative_hot_water_efficiency_pct": 53.8, "output_kw_max": 14.0, "final_year_of_manufacture": 2002, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001766", "000035", "0", "2020/Sep/02 14:12", "Worcester Heat Systems", "Worcester", "Danesmoor", "12/14.ROO", "C14769/2-1", "1995", "2002", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "12", "14", "", "", "85.4", "73.7", "", "53.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "83.7", "88.9", "", "", "", "", "87.9"]} +{"pcdb_id": 1767, "brand_name": "Worcester", "model_name": "Danesmoor", "model_qualifier": "12/14.OOO", "winter_efficiency_pct": 85.4, "summer_efficiency_pct": 73.7, "comparative_hot_water_efficiency_pct": 53.8, "output_kw_max": 14.0, "final_year_of_manufacture": 2002, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001767", "000035", "0", "2020/Sep/02 14:12", "Worcester Heat Systems", "Worcester", "Danesmoor", "12/14.OOO", "C14769/2-1", "1995", "2002", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "12", "14", "", "", "85.4", "73.7", "", "53.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "83.7", "88.9", "", "", "", "", "87.9"]} +{"pcdb_id": 1768, "brand_name": "Worcester", "model_name": "Danesmoor", "model_qualifier": "15/19.ROO", "winter_efficiency_pct": 86.4, "summer_efficiency_pct": 74.7, "comparative_hot_water_efficiency_pct": 54.6, "output_kw_max": 19.0, "final_year_of_manufacture": 2008, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001768", "000035", "0", "2020/Sep/02 14:12", "Worcester Heat Systems", "Worcester", "Danesmoor", "15/19.ROO", "C14769/3-1", "1995", "2008", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "15", "19", "", "", "86.4", "74.7", "", "54.6", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.6", "87.9", "", "", "", "", "87.5"]} +{"pcdb_id": 1770, "brand_name": "Worcester", "model_name": "Danesmoor", "model_qualifier": "15/19.OOO", "winter_efficiency_pct": 86.4, "summer_efficiency_pct": 74.7, "comparative_hot_water_efficiency_pct": 54.6, "output_kw_max": 19.0, "final_year_of_manufacture": 2008, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001770", "000035", "0", "2020/Sep/02 14:12", "Worcester Heat Systems", "Worcester", "Danesmoor", "15/19.OOO", "C14769/3-1", "1995", "2008", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "15", "19", "", "", "86.4", "74.7", "", "54.6", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.6", "87.9", "", "", "", "", "87.5"]} +{"pcdb_id": 1774, "brand_name": "Worcester", "model_name": "Danesmoor", "model_qualifier": "20/25.ROO", "winter_efficiency_pct": 85.0, "summer_efficiency_pct": 73.3, "comparative_hot_water_efficiency_pct": 53.6, "output_kw_max": 25.0, "final_year_of_manufacture": 2002, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001774", "000035", "0", "2020/Sep/02 14:12", "Worcester Heat Systems", "Worcester", "Danesmoor", "20/25.ROO", "C14769/4-1", "1995", "2002", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "20", "25", "", "", "85.0", "73.3", "", "53.6", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "83.3", "86.8", "", "", "", "", "86.1"]} +{"pcdb_id": 1776, "brand_name": "Worcester", "model_name": "Danesmoor", "model_qualifier": "20/25.OOO", "winter_efficiency_pct": 85.0, "summer_efficiency_pct": 73.3, "comparative_hot_water_efficiency_pct": 53.6, "output_kw_max": 25.0, "final_year_of_manufacture": 2002, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001776", "000035", "0", "2020/Sep/02 14:12", "Worcester Heat Systems", "Worcester", "Danesmoor", "20/25.OOO", "C14769/4-1", "1995", "2002", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "20", "25", "", "", "85.0", "73.3", "", "53.6", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "83.3", "86.8", "", "", "", "", "86.1"]} +{"pcdb_id": 1778, "brand_name": "Worcester", "model_name": "Danesmoor", "model_qualifier": "26/32.ROO", "winter_efficiency_pct": 86.2, "summer_efficiency_pct": 74.5, "comparative_hot_water_efficiency_pct": 54.4, "output_kw_max": 32.0, "final_year_of_manufacture": 2008, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001778", "000035", "0", "2020/Sep/02 14:12", "Worcester Heat Systems", "Worcester", "Danesmoor", "26/32.ROO", "C14769/5-1", "1995", "2008", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "26", "32", "", "", "86.2", "74.5", "", "54.4", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.3", "88.1", "", "", "", "", "87.5"]} +{"pcdb_id": 1779, "brand_name": "Worcester", "model_name": "Danesmoor", "model_qualifier": "26/32.OOO", "winter_efficiency_pct": 86.2, "summer_efficiency_pct": 74.5, "comparative_hot_water_efficiency_pct": 54.4, "output_kw_max": 32.0, "final_year_of_manufacture": 2008, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001779", "000035", "0", "2020/Sep/02 14:13", "Worcester Heat Systems", "Worcester", "Danesmoor", "26/32.OOO", "C14769/5-1", "1995", "2008", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "26", "32", "", "", "86.2", "74.5", "", "54.4", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.3", "88.1", "", "", "", "", "87.5"]} +{"pcdb_id": 1781, "brand_name": "Worcester", "model_name": "Danesmoor Utility", "model_qualifier": "12/14.ROO", "winter_efficiency_pct": 85.4, "summer_efficiency_pct": 73.7, "comparative_hot_water_efficiency_pct": 53.8, "output_kw_max": 14.0, "final_year_of_manufacture": 2002, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001781", "000035", "0", "2020/Sep/02 14:13", "Worcester Heat Systems", "Worcester", "Danesmoor Utility", "12/14.ROO", "C14769/2-1", "1995", "2002", "4", "1", "0", "1", "0", "", "", "1", "1", "2", "12", "14", "", "", "85.4", "73.7", "", "53.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "83.7", "88.9", "", "", "", "", "87.9"]} +{"pcdb_id": 1784, "brand_name": "Worcester", "model_name": "Danesmoor Utility", "model_qualifier": "12/14.OOO", "winter_efficiency_pct": 85.4, "summer_efficiency_pct": 73.7, "comparative_hot_water_efficiency_pct": 53.8, "output_kw_max": 14.0, "final_year_of_manufacture": 2002, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001784", "000035", "0", "2020/Sep/02 14:13", "Worcester Heat Systems", "Worcester", "Danesmoor Utility", "12/14.OOO", "C14769/2-1", "1995", "2002", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "12", "14", "", "", "85.4", "73.7", "", "53.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "83.7", "88.9", "", "", "", "", "87.9"]} +{"pcdb_id": 1785, "brand_name": "Worcester", "model_name": "Danesmoor Utility", "model_qualifier": "15/19.ROO", "winter_efficiency_pct": 86.4, "summer_efficiency_pct": 74.7, "comparative_hot_water_efficiency_pct": 54.6, "output_kw_max": 19.0, "final_year_of_manufacture": 2008, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001785", "000035", "0", "2020/Sep/02 14:13", "Worcester Heat Systems", "Worcester", "Danesmoor Utility", "15/19.ROO", "C14769/3-1", "1995", "2008", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "15", "19", "", "", "86.4", "74.7", "", "54.6", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.6", "87.9", "", "", "", "", "87.5"]} +{"pcdb_id": 1786, "brand_name": "Worcester", "model_name": "Danesmoor Utility", "model_qualifier": "15/19.OOO", "winter_efficiency_pct": 86.4, "summer_efficiency_pct": 74.7, "comparative_hot_water_efficiency_pct": 54.6, "output_kw_max": 19.0, "final_year_of_manufacture": 2008, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001786", "000035", "0", "2020/Sep/02 14:13", "Worcester Heat Systems", "Worcester", "Danesmoor Utility", "15/19.OOO", "C14769/3-1", "1995", "2008", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "15", "19", "", "", "86.4", "74.7", "", "54.6", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.6", "87.9", "", "", "", "", "87.5"]} +{"pcdb_id": 1787, "brand_name": "Worcester", "model_name": "Danesmoor Utility", "model_qualifier": "20/25.ROO", "winter_efficiency_pct": 85.0, "summer_efficiency_pct": 73.3, "comparative_hot_water_efficiency_pct": 53.6, "output_kw_max": 25.0, "final_year_of_manufacture": 2002, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001787", "000035", "0", "2020/Sep/02 14:13", "Worcester Heat Systems", "Worcester", "Danesmoor Utility", "20/25.ROO", "C14769/4-1", "1995", "2002", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "20", "25", "", "", "85.0", "73.3", "", "53.6", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "83.3", "86.8", "", "", "", "", "86.1"]} +{"pcdb_id": 1788, "brand_name": "Worcester", "model_name": "Danesmoor Utility", "model_qualifier": "20/25.OOO", "winter_efficiency_pct": 85.0, "summer_efficiency_pct": 73.3, "comparative_hot_water_efficiency_pct": 53.6, "output_kw_max": 25.0, "final_year_of_manufacture": 2002, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001788", "000035", "0", "2020/Sep/02 14:13", "Worcester Heat Systems", "Worcester", "Danesmoor Utility", "20/25.OOO", "C14769/4-1", "1995", "2002", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "20", "25", "", "", "85.0", "73.3", "", "53.6", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "83.3", "86.8", "", "", "", "", "86.1"]} +{"pcdb_id": 1790, "brand_name": "Worcester", "model_name": "Bosch RX-2", "model_qualifier": "RSF", "winter_efficiency_pct": 84.8, "summer_efficiency_pct": 76.2, "comparative_hot_water_efficiency_pct": 53.6, "output_kw_max": 26.0, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001790", "000035", "0", "2002/Aug/14 10:22", "Worcester Heat Systems", "Worcester", "Bosch RX-2", "RSF", "47 311 41", "1999", "2001", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "26", "26", "", "", "84.8", "76.2", "", "53.6", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "85.6", "90.1", "", "", "", "", "89.2"]} +{"pcdb_id": 1814, "brand_name": "Sime Heating Products (UK)", "model_name": "Sime", "model_qualifier": "Super 4", "winter_efficiency_pct": 79.1, "summer_efficiency_pct": 70.0, "comparative_hot_water_efficiency_pct": 42.8, "output_kw_max": 28.5, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001814", "000213", "0", "2024/Jan/31 10:17", "Sime Heating Products (UK)", "Sime Heating Products (UK)", "Sime", "Super 4", "", "1995", "2018", "1", "1", "1", "2", "0", "", "", "1", "2", "2", "28.5", "28.5", "", "", "79.1", "70.0", "", "42.8", "", "2", "", "", "106", "1", "2", "150", "12.2", "2", "2", "0", "50", "0", "25", "2", "62", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.2", "77.5", "", "", "", "", "78.4"]} +{"pcdb_id": 1815, "brand_name": "Sime Heating Products (UK)", "model_name": "Format", "model_qualifier": "Friendly e", "winter_efficiency_pct": 80.2, "summer_efficiency_pct": 70.1, "comparative_hot_water_efficiency_pct": 49.3, "output_kw_max": 23.4, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001815", "000213", "0", "2018/Mar/05 15:15", "Sime Heating Products (UK)", "Sime Heating Products (UK)", "Format", "Friendly e", "", "1998", "2018", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "23.4", "23.4", "", "", "80.2", "70.1", "", "49.3", "", "2", "", "", "104", "1", "2", "150", "12.5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.7", "80.1", "", "", "", "", "80.6"]} +{"pcdb_id": 1816, "brand_name": "Sime Heating Products (UK)", "model_name": "Format", "model_qualifier": "Friendly", "winter_efficiency_pct": 80.2, "summer_efficiency_pct": 70.1, "comparative_hot_water_efficiency_pct": 49.3, "output_kw_max": 23.4, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001816", "000213", "0", "2018/Mar/05 15:15", "Sime Heating Products (UK)", "Sime Heating Products (UK)", "Format", "Friendly", "", "1998", "2018", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "23.4", "23.4", "", "", "80.2", "70.1", "", "49.3", "", "2", "", "", "104", "1", "2", "150", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.7", "80.1", "", "", "", "", "80.6"]} +{"pcdb_id": 1817, "brand_name": "Sime Heating Products (UK)", "model_name": "Format", "model_qualifier": "super 100", "winter_efficiency_pct": 79.5, "summer_efficiency_pct": 69.4, "comparative_hot_water_efficiency_pct": 48.8, "output_kw_max": 29.3, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001817", "000213", "0", "2018/Mar/05 15:16", "Sime Heating Products (UK)", "Sime Heating Products (UK)", "Format", "super 100", "", "1998", "2018", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "29.3", "29.3", "", "", "79.5", "69.4", "", "48.8", "", "2", "", "", "104", "1", "2", "150", "12.5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.9", "78.6", "", "", "", "", "79.4"]} +{"pcdb_id": 1818, "brand_name": "Sime Heating Products (UK)", "model_name": "Murrelle", "model_qualifier": "", "winter_efficiency_pct": 76.2, "summer_efficiency_pct": 66.1, "comparative_hot_water_efficiency_pct": 46.5, "output_kw_max": 23.4, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001818", "000213", "0", "2018/Mar/05 15:16", "Sime Heating Products (UK)", "Sime Heating Products (UK)", "Murrelle", "", "c/f", "1995", "2018", "1", "2", "1", "2", "0", "", "", "1", "1", "1", "23.4", "23.4", "", "", "76.2", "66.1", "", "46.5", "", "2", "", "", "104", "2", "2", "150", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.7", "80.1", "", "", "", "", "80.6"]} +{"pcdb_id": 1821, "brand_name": "Vaillant", "model_name": "Turbomax", "model_qualifier": "VUW 242 EH", "winter_efficiency_pct": 79.4, "summer_efficiency_pct": 69.3, "comparative_hot_water_efficiency_pct": 48.8, "output_kw_max": 24.0, "final_year_of_manufacture": 2000, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001821", "000031", "0", "2006/Jan/17 12:55", "Vaillant", "Vaillant", "Turbomax", "VUW 242 EH", "VUW GB 242/1 EH", "1995", "2000", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "24.0", "24.0", "", "", "79.4", "69.3", "", "48.8", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.4", "78.8", "", "", "", "", "79.5"]} +{"pcdb_id": 1822, "brand_name": "Vaillant", "model_name": "Turbomax", "model_qualifier": "VUW 282 EH", "winter_efficiency_pct": 79.6, "summer_efficiency_pct": 69.5, "comparative_hot_water_efficiency_pct": 48.9, "output_kw_max": 28.0, "final_year_of_manufacture": 2000, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001822", "000031", "0", "2006/Jan/17 12:55", "Vaillant", "Vaillant", "Turbomax", "VUW 282 EH", "VUW GB 282/1 EH", "1995", "2000", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "28.0", "28.0", "", "", "79.6", "69.5", "", "48.9", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.7", "78.8", "", "", "", "", "79.6"]} +{"pcdb_id": 1824, "brand_name": "Vaillant", "model_name": "Thermocompact", "model_qualifier": "VU 282 EH", "winter_efficiency_pct": 79.8, "summer_efficiency_pct": 69.1, "comparative_hot_water_efficiency_pct": 50.5, "output_kw_max": 24.0, "final_year_of_manufacture": 2000, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001824", "000031", "0", "2012/Mar/27 10:12", "Vaillant", "Vaillant", "Thermocompact", "VU 282 EH", "VU GB 282/1 EH", "1996", "2000", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "24.0", "24.0", "", "", "79.8", "69.1", "", "50.5", "", "2", "", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.7", "78.8", "", "", "", "", "79.6"]} +{"pcdb_id": 1826, "brand_name": "Vaillant", "model_name": "Thermocompact", "model_qualifier": "VU 242 EH", "winter_efficiency_pct": 79.6, "summer_efficiency_pct": 68.9, "comparative_hot_water_efficiency_pct": 50.4, "output_kw_max": 24.0, "final_year_of_manufacture": 2000, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001826", "000031", "0", "2012/Mar/27 10:12", "Vaillant", "Vaillant", "Thermocompact", "VU 242 EH", "VU GB 242/1 EH", "1996", "2000", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "24.0", "24.0", "", "", "79.6", "68.9", "", "50.4", "", "2", "", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.4", "78.8", "", "", "", "", "79.5"]} +{"pcdb_id": 1828, "brand_name": "Vaillant", "model_name": "Thermocompact", "model_qualifier": "VU 182 EH", "winter_efficiency_pct": 79.1, "summer_efficiency_pct": 68.4, "comparative_hot_water_efficiency_pct": 49.9, "output_kw_max": 18.0, "final_year_of_manufacture": 2000, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001828", "000031", "0", "2012/Mar/27 10:12", "Vaillant", "Vaillant", "Thermocompact", "VU 182 EH", "VU GB 182/1 EH", "1996", "2000", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "18.0", "18.0", "", "", "79.1", "68.4", "", "49.9", "", "2", "", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.3", "77.8", "", "", "", "", "78.7"]} +{"pcdb_id": 1830, "brand_name": "Vaillant", "model_name": "Thermocompact", "model_qualifier": "VU 142 EH", "winter_efficiency_pct": 76.8, "summer_efficiency_pct": 66.1, "comparative_hot_water_efficiency_pct": 48.3, "output_kw_max": 14.0, "final_year_of_manufacture": 2000, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001830", "000031", "0", "2012/Mar/27 10:12", "Vaillant", "Vaillant", "Thermocompact", "VU 142 EH", "VU GB 142/1EH", "1998", "2000", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "14.0", "14.0", "", "", "76.8", "66.1", "", "48.3", "", "2", "", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "79.9", "75.7", "", "", "", "", "76.5"]} +{"pcdb_id": 1832, "brand_name": "Vaillant", "model_name": "Ecomax", "model_qualifier": "VU 186 EH", "winter_efficiency_pct": 87.0, "summer_efficiency_pct": 78.0, "comparative_hot_water_efficiency_pct": 57.0, "output_kw_max": 17.2, "final_year_of_manufacture": 2000, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001832", "000031", "0", "2012/Mar/27 10:12", "Vaillant", "Vaillant", "Ecomax", "VU 186 EH", "VU GB 186 EH", "1995", "2000", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "17.2", "17.2", "", "", "87.0", "78.0", "", "57.0", "", "2", "", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.6", "94.1", "", "", "", "", "93.0"]} +{"pcdb_id": 1834, "brand_name": "Vaillant", "model_name": "Ecomax", "model_qualifier": "VU 226 EH", "winter_efficiency_pct": 87.0, "summer_efficiency_pct": 78.0, "comparative_hot_water_efficiency_pct": 57.0, "output_kw_max": 21.3, "final_year_of_manufacture": 2000, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001834", "000031", "0", "2012/Mar/27 10:12", "Vaillant", "Vaillant", "Ecomax", "VU 226 EH", "VU GB 226 EH", "1995", "2000", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "21.3", "21.3", "", "", "87.0", "78.0", "", "57.0", "", "2", "", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.5", "94.2", "", "", "", "", "93.1"]} +{"pcdb_id": 1838, "brand_name": "Vaillant", "model_name": "Ecomax", "model_qualifier": "828 E", "winter_efficiency_pct": 87.0, "summer_efficiency_pct": 78.4, "comparative_hot_water_efficiency_pct": 55.1, "output_kw_max": 21.5, "final_year_of_manufacture": 2000, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001838", "000031", "0", "2006/Jan/17 12:55", "Vaillant", "Vaillant", "Ecomax", "828 E", "VUW GB 286E CH", "1999", "2000", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "21.5", "21.5", "", "", "87.0", "78.4", "", "55.1", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "84.9", "96.5", "", "", "", "", "94.3"]} +{"pcdb_id": 1839, "brand_name": "Vaillant", "model_name": "Ecomax", "model_qualifier": "824 E", "winter_efficiency_pct": 86.8, "summer_efficiency_pct": 78.2, "comparative_hot_water_efficiency_pct": 55.0, "output_kw_max": 17.7, "final_year_of_manufacture": 2000, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001839", "000031", "0", "2006/Jan/17 12:55", "Vaillant", "Vaillant", "Ecomax", "824 E", "VUW GB 246E CH", "1999", "2000", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "17.7", "17.7", "", "", "86.8", "78.2", "", "55.0", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "84.7", "96.3", "", "", "", "", "94.1"]} +{"pcdb_id": 1840, "brand_name": "Baxi Heating", "model_name": "Barcelona", "model_qualifier": "", "winter_efficiency_pct": 87.6, "summer_efficiency_pct": 78.6, "comparative_hot_water_efficiency_pct": 57.4, "output_kw_max": 31.05, "final_year_of_manufacture": 2002, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001840", "000005", "0", "2012/Mar/27 10:12", "Baxi Heating", "Baxi Heating", "Barcelona", "", "GC No 41-075-02", "1999", "2002", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "31.05", "31.05", "", "", "87.6", "78.6", "", "57.4", "", "2", "", "", "102", "1", "2", "80", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "91.0", "94.4", "", "", "", "", "93.8"]} +{"pcdb_id": 1841, "brand_name": "Baxi Heating", "model_name": "Bahama", "model_qualifier": "100", "winter_efficiency_pct": 80.4, "summer_efficiency_pct": 70.3, "comparative_hot_water_efficiency_pct": 49.5, "output_kw_max": 29.3, "final_year_of_manufacture": 2002, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001841", "000005", "0", "2008/Jun/26 09:26", "Baxi Heating", "Baxi Heating", "Bahama", "100", "GC No 47-075-01", "1998", "2002", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "29.3", "29.3", "", "", "80.4", "70.3", "", "49.5", "", "2", "", "", "104", "1", "2", "200", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.0", "81.3", "", "", "", "", "81.4"]} +{"pcdb_id": 1842, "brand_name": "Baxi Heating", "model_name": "Bermuda", "model_qualifier": "45/4E", "winter_efficiency_pct": 77.7, "summer_efficiency_pct": 67.6, "comparative_hot_water_efficiency_pct": 49.4, "output_kw_max": 13.19, "final_year_of_manufacture": 2003, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001842", "000005", "0", "2012/Mar/27 10:12", "Baxi Heating", "Baxi Heating", "Bermuda", "45/4E", "GC No 44-077-73", "1997", "2003", "1", "4", "1", "1", "0", "", "", "1", "1", "1", "10.26", "13.19", "", "", "77.7", "67.6", "", "49.4", "", "2", "", "", "101", "1", "1", "0", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.4", "79.2", "", "", "", "", "79.2"]} +{"pcdb_id": 1843, "brand_name": "Baxi Heating", "model_name": "Bermuda", "model_qualifier": "45/4M", "winter_efficiency_pct": 73.6, "summer_efficiency_pct": 63.5, "comparative_hot_water_efficiency_pct": 46.3, "output_kw_max": 13.19, "final_year_of_manufacture": 2002, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001843", "000005", "0", "2012/Mar/27 10:12", "Baxi Heating", "Baxi Heating", "Bermuda", "45/4M", "GC No 44-077-71", "1996", "2002", "1", "4", "1", "1", "0", "", "", "1", "1", "1", "10.26", "13.19", "", "", "73.6", "63.5", "", "46.3", "", "2", "", "", "101", "2", "1", "0", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.4", "78.9", "", "", "", "", "79.0"]} +{"pcdb_id": 1844, "brand_name": "Baxi Heating", "model_name": "Bermuda", "model_qualifier": "57/4E", "winter_efficiency_pct": 76.7, "summer_efficiency_pct": 66.6, "comparative_hot_water_efficiency_pct": 48.6, "output_kw_max": 16.85, "final_year_of_manufacture": 2005, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001844", "000005", "0", "2012/Mar/27 10:12", "Baxi Heating", "Baxi Heating", "Bermuda", "57/4E", "GC No 44-077-74", "1997", "2005", "1", "4", "1", "1", "0", "", "", "1", "1", "1", "13.19", "16.85", "", "", "76.7", "66.6", "", "48.6", "", "2", "", "", "101", "1", "1", "0", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "78.8", "77.8", "", "", "", "", "78.0"]} +{"pcdb_id": 1845, "brand_name": "Baxi Heating", "model_name": "Bermuda", "model_qualifier": "57/4M", "winter_efficiency_pct": 72.7, "summer_efficiency_pct": 62.6, "comparative_hot_water_efficiency_pct": 45.7, "output_kw_max": 16.85, "final_year_of_manufacture": 2002, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001845", "000005", "0", "2012/Mar/27 10:12", "Baxi Heating", "Baxi Heating", "Bermuda", "57/4M", "GC No 44-077-72", "1996", "2002", "1", "4", "1", "1", "0", "", "", "1", "1", "1", "13.19", "16.85", "", "", "72.7", "62.6", "", "45.7", "", "2", "", "", "101", "2", "1", "0", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "78.8", "77.7", "", "", "", "", "77.9"]} +{"pcdb_id": 1846, "brand_name": "Baxi Heating", "model_name": "Solo PF 3", "model_qualifier": "30", "winter_efficiency_pct": 79.7, "summer_efficiency_pct": 69.6, "comparative_hot_water_efficiency_pct": 50.8, "output_kw_max": 8.9, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001846", "000005", "0", "2012/Mar/27 10:12", "Baxi Heating", "Baxi Heating", "Solo PF 3", "30", "GC No 41-075-04", "1999", "2001", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "5.86", "8.9", "", "", "79.7", "69.6", "", "50.8", "", "2", "", "", "101", "1", "1", "90", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.7", "80.8", "", "", "", "", "81.0"]} +{"pcdb_id": 1847, "brand_name": "Baxi Heating", "model_name": "Solo PF 3", "model_qualifier": "40", "winter_efficiency_pct": 78.7, "summer_efficiency_pct": 68.6, "comparative_hot_water_efficiency_pct": 50.1, "output_kw_max": 11.72, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001847", "000005", "0", "2012/Mar/27 10:12", "Baxi Heating", "Baxi Heating", "Solo PF 3", "40", "GC No 41-075-05", "1999", "2001", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "9.09", "11.72", "", "", "78.7", "68.6", "", "50.1", "", "2", "", "", "101", "1", "1", "90", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.2", "81.4", "", "", "", "", "80.9"]} +{"pcdb_id": 1848, "brand_name": "Baxi Heating", "model_name": "Solo PF 3", "model_qualifier": "50", "winter_efficiency_pct": 77.6, "summer_efficiency_pct": 67.5, "comparative_hot_water_efficiency_pct": 49.3, "output_kw_max": 14.65, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001848", "000005", "0", "2012/Mar/27 10:12", "Baxi Heating", "Baxi Heating", "Solo PF 3", "50", "GC No 41-075-06", "1999", "2001", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "12.02", "14.65", "", "", "77.6", "67.5", "", "49.3", "", "2", "", "", "101", "1", "1", "90", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "78.9", "79.5", "", "", "", "", "79.4"]} +{"pcdb_id": 1849, "brand_name": "Baxi Heating", "model_name": "Solo PF 3", "model_qualifier": "60", "winter_efficiency_pct": 78.7, "summer_efficiency_pct": 68.6, "comparative_hot_water_efficiency_pct": 50.1, "output_kw_max": 17.58, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001849", "000005", "0", "2012/Mar/27 10:12", "Baxi Heating", "Baxi Heating", "Solo PF 3", "60", "GC No 41-075-07", "1999", "2001", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "14.95", "17.58", "", "", "78.7", "68.6", "", "50.1", "", "2", "", "", "101", "1", "1", "90", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.9", "80.6", "", "", "", "", "80.5"]} +{"pcdb_id": 1850, "brand_name": "Baxi Heating", "model_name": "Solo PF 3", "model_qualifier": "70", "winter_efficiency_pct": 78.6, "summer_efficiency_pct": 68.5, "comparative_hot_water_efficiency_pct": 50.1, "output_kw_max": 20.5, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001850", "000005", "0", "2012/Mar/27 10:12", "Baxi Heating", "Baxi Heating", "Solo PF 3", "70", "GC No 41-075-08", "1999", "2001", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "17.88", "20.5", "", "", "78.6", "68.5", "", "50.1", "", "2", "", "", "101", "1", "1", "90", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "80.0", "80.5", "", "", "", "", "80.4"]} +{"pcdb_id": 1851, "brand_name": "Baxi Heating", "model_name": "Solo PF 3", "model_qualifier": "80", "winter_efficiency_pct": 78.7, "summer_efficiency_pct": 68.6, "comparative_hot_water_efficiency_pct": 50.1, "output_kw_max": 23.45, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001851", "000005", "0", "2012/Mar/27 10:12", "Baxi Heating", "Baxi Heating", "Solo PF 3", "80", "GC No 41-075-09", "1999", "2001", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "20.8", "23.45", "", "", "78.7", "68.6", "", "50.1", "", "2", "", "", "101", "1", "1", "90", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.9", "80.6", "", "", "", "", "80.5"]} +{"pcdb_id": 1852, "brand_name": "Baxi Heating", "model_name": "Bermuda Inset 2", "model_qualifier": "50/4", "winter_efficiency_pct": 72.9, "summer_efficiency_pct": 62.8, "comparative_hot_water_efficiency_pct": 45.9, "output_kw_max": 14.65, "final_year_of_manufacture": 2002, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001852", "000005", "0", "2012/Mar/27 10:12", "Baxi Heating", "Baxi Heating", "Bermuda Inset 2", "50/4", "GC No 44-075-01", "1997", "2002", "1", "4", "1", "1", "0", "", "", "1", "1", "1", "11.72", "14.65", "", "", "72.9", "62.8", "", "45.9", "", "2", "", "", "101", "2", "1", "0", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "78.7", "78.3", "", "", "", "", "78.4"]} +{"pcdb_id": 1853, "brand_name": "Trianco", "model_name": "Eurostar", "model_qualifier": "50/65", "winter_efficiency_pct": 77.4, "summer_efficiency_pct": 67.3, "comparative_hot_water_efficiency_pct": 49.2, "output_kw_max": 19.0, "final_year_of_manufacture": 2003, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001853", "000062", "0", "2012/Mar/27 10:12", "Trianco Redfyre", "Trianco", "Eurostar", "50/65", "13961/1", "1997", "2003", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "14.7", "19.0", "", "", "77.4", "67.3", "", "49.2", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.2", "78.8", "", "", "", "", "78.9"]} +{"pcdb_id": 1854, "brand_name": "Ferroli", "model_name": "Optima 201", "model_qualifier": "", "winter_efficiency_pct": 75.1, "summer_efficiency_pct": 65.0, "comparative_hot_water_efficiency_pct": 45.7, "output_kw_max": 23.3, "final_year_of_manufacture": 1997, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001854", "000097", "0", "2006/Jan/17 12:55", "Ferroli SpA", "Ferroli", "Optima 201", "", "", "1996", "1997", "1", "2", "1", "2", "0", "", "", "1", "1", "1", "23.3", "23.3", "", "", "75.1", "65.0", "", "45.7", "", "2", "", "", "104", "2", "2", "", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.5", "79.1", "", "", "", "", "79.6"]} +{"pcdb_id": 1855, "brand_name": "Trianco", "model_name": "Eurostar", "model_qualifier": "190/240", "winter_efficiency_pct": 86.2, "summer_efficiency_pct": 74.5, "comparative_hot_water_efficiency_pct": 54.4, "output_kw_max": null, "final_year_of_manufacture": 2003, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001855", "000062", "0", "2012/Mar/27 10:12", "Trianco Redfyre", "Trianco", "Eurostar", "190/240", "13961/6", "1998", "2003", "4", "1", "2", "1", "0", "", "", "1", "1", "1", "55.7", ">70kW", "", "", "86.2", "74.5", "", "54.4", "", "2", "", "", "201", "1", "1", "148", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.6", "86.1", "", "", "", "", "86.2"]} +{"pcdb_id": 1856, "brand_name": "Ferroli", "model_name": "Domina 80", "model_qualifier": "", "winter_efficiency_pct": 80.5, "summer_efficiency_pct": 70.4, "comparative_hot_water_efficiency_pct": 49.5, "output_kw_max": 23.8, "final_year_of_manufacture": 2006, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001856", "000097", "0", "2009/Apr/28 16:22", "Ferroli SpA", "Ferroli", "Domina 80", "", "", "1997", "2006", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "23.8", "23.8", "", "", "80.5", "70.4", "", "49.5", "", "2", "", "", "104", "1", "2", "", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "83.1", "80.5", "", "", "", "", "81.0"]} +{"pcdb_id": 1857, "brand_name": "Trianco", "model_name": "Eurostar", "model_qualifier": "50/65 I.T.W.", "winter_efficiency_pct": 86.5, "summer_efficiency_pct": 74.8, "comparative_hot_water_efficiency_pct": 54.7, "output_kw_max": 19.0, "final_year_of_manufacture": 2004, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001857", "000062", "0", "2012/Mar/27 10:12", "Trianco Redfyre", "Trianco", "Eurostar", "50/65 I.T.W.", "13961/11", "1998", "2004", "4", "2", "1", "1", "0", "", "", "1", "1", "1", "14.6", "19", "", "", "86.5", "74.8", "", "54.7", "", "2", "", "", "201", "1", "1", "148", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.9", "87.9", "", "", "", "", "87.5"]} +{"pcdb_id": 1858, "brand_name": "Ferroli", "model_name": "Modena 80", "model_qualifier": "", "winter_efficiency_pct": 80.5, "summer_efficiency_pct": 70.4, "comparative_hot_water_efficiency_pct": 49.5, "output_kw_max": 23.8, "final_year_of_manufacture": 2005, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001858", "000097", "0", "2009/Apr/28 16:13", "Ferroli SpA", "Ferroli", "Modena 80", "", "", "1998", "2005", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "23.8", "23.8", "", "", "80.5", "70.4", "", "49.5", "", "2", "", "", "104", "1", "2", "", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "83.1", "80.5", "", "", "", "", "81.0"]} +{"pcdb_id": 1859, "brand_name": "Trianco", "model_name": "Eurostar", "model_qualifier": "90 Combi", "winter_efficiency_pct": 84.6, "summer_efficiency_pct": 76.5, "comparative_hot_water_efficiency_pct": 44.7, "output_kw_max": 27.5, "final_year_of_manufacture": 2003, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001859", "000062", "0", "2024/Jan/31 10:17", "Trianco Redfyre", "Trianco", "Eurostar", "90 Combi", "12579/1", "1997", "2003", "4", "1", "2", "2", "0", "", "", "1", "1", "1", "27.5", "27.5", "", "", "84.6", "76.5", "", "44.7", "", "2", "", "", "203", "1", "1", "1.2", "5.5", "2", "1", "0", "69", "0", "25", "1", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.9", "88.8", "", "", "", "", "88.3"]} +{"pcdb_id": 1860, "brand_name": "Ferroli", "model_name": "Tempra", "model_qualifier": "", "winter_efficiency_pct": 78.4, "summer_efficiency_pct": 68.3, "comparative_hot_water_efficiency_pct": 49.9, "output_kw_max": 17.6, "final_year_of_manufacture": 2000, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001860", "000097", "0", "2012/Mar/27 10:12", "Ferroli SpA", "Ferroli", "Tempra", "", "", "1999", "2000", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "14.4", "17.6", "", "", "78.4", "68.3", "", "49.9", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.1", "78.8", "", "", "", "", "79.3"]} +{"pcdb_id": 1861, "brand_name": "Ferroli", "model_name": "Optima 2001", "model_qualifier": "", "winter_efficiency_pct": 84.9, "summer_efficiency_pct": 76.3, "comparative_hot_water_efficiency_pct": 53.7, "output_kw_max": 22.6, "final_year_of_manufacture": 2000, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001861", "000097", "0", "2006/Jan/17 12:55", "Ferroli SpA", "Ferroli", "Optima 2001", "", "", "1996", "2000", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "22.6", "22.6", "", "", "84.9", "76.3", "", "53.7", "", "2", "", "", "104", "1", "2", "", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "86.9", "89.5", "", "", "", "", "89.0"]} +{"pcdb_id": 1862, "brand_name": "Trianco", "model_name": "Eurostar", "model_qualifier": "130/150", "winter_efficiency_pct": 82.8, "summer_efficiency_pct": 71.1, "comparative_hot_water_efficiency_pct": 51.9, "output_kw_max": 44.0, "final_year_of_manufacture": 2003, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001862", "000062", "0", "2012/Mar/27 10:12", "Trianco Redfyre", "Trianco", "Eurostar", "130/150", "13961/4.", "1997", "2003", "4", "1", "2", "1", "0", "", "", "1", "1", "2", "38.1", "44", "", "", "82.8", "71.1", "", "51.9", "", "2", "", "", "201", "1", "1", "148", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.4", "83.2", "", "", "", "", "83.0"]} +{"pcdb_id": 1863, "brand_name": "Ferroli", "model_name": "Sigma 30", "model_qualifier": "", "winter_efficiency_pct": 77.8, "summer_efficiency_pct": 67.7, "comparative_hot_water_efficiency_pct": 49.5, "output_kw_max": 8.8, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001863", "000097", "0", "2012/Mar/27 10:12", "Ferroli SpA", "Ferroli", "Sigma 30", "", "", "1999", "2001", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "5.5", "8.8", "", "", "77.8", "67.7", "", "49.5", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "80.4", "78.5", "", "", "", "", "78.8"]} +{"pcdb_id": 1864, "brand_name": "Ferroli", "model_name": "Sigma 40", "model_qualifier": "", "winter_efficiency_pct": 78.6, "summer_efficiency_pct": 68.5, "comparative_hot_water_efficiency_pct": 50.0, "output_kw_max": 11.7, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001864", "000097", "0", "2012/Mar/27 10:12", "Ferroli SpA", "Ferroli", "Sigma 40", "", "", "1999", "2001", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "8.5", "11.7", "", "", "78.6", "68.5", "", "50.0", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.9", "78.5", "", "", "", "", "79.1"]} +{"pcdb_id": 1865, "brand_name": "Ferroli", "model_name": "Sigma 50", "model_qualifier": "", "winter_efficiency_pct": 78.2, "summer_efficiency_pct": 68.1, "comparative_hot_water_efficiency_pct": 49.7, "output_kw_max": 14.7, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001865", "000097", "0", "2012/Mar/27 10:12", "Ferroli SpA", "Ferroli", "Sigma 50", "", "", "1999", "2001", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "11.4", "14.7", "", "", "78.2", "68.1", "", "49.7", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "80.9", "78.7", "", "", "", "", "79.1"]} +{"pcdb_id": 1866, "brand_name": "Ferroli", "model_name": "Sigma 60", "model_qualifier": "", "winter_efficiency_pct": 78.4, "summer_efficiency_pct": 68.3, "comparative_hot_water_efficiency_pct": 49.9, "output_kw_max": 17.6, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001866", "000097", "0", "2012/Mar/27 10:12", "Ferroli SpA", "Ferroli", "Sigma 60", "", "", "1999", "2001", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "14.4", "17.6", "", "", "78.4", "68.3", "", "49.9", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.1", "78.8", "", "", "", "", "79.3"]} +{"pcdb_id": 1867, "brand_name": "Trianco", "model_name": "Eurostar", "model_qualifier": "65 Combi", "winter_efficiency_pct": 80.3, "summer_efficiency_pct": 72.2, "comparative_hot_water_efficiency_pct": 43.0, "output_kw_max": 19.5, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001867", "000062", "0", "2024/Jan/31 10:17", "Trianco Redfyre", "Trianco", "Eurostar", "65 Combi", "12579/1", "1997", "2001", "4", "1", "2", "2", "0", "", "", "1", "1", "1", "19.5", "19.5", "", "", "80.3", "72.2", "", "43.0", "", "2", "", "", "203", "1", "1", "1.2", "5.5", "2", "1", "0", "63", "0", "25", "1", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.4", "82.0", "", "", "", "", "82.1"]} +{"pcdb_id": 1868, "brand_name": "Trianco", "model_name": "Eurostar", "model_qualifier": "100/125", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 36.6, "final_year_of_manufacture": 2003, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001868", "000062", "0", "2012/Mar/27 10:12", "Trianco Redfyre", "Trianco", "Eurostar", "100/125", "13961/3", "1997", "2003", "4", "1", "2", "1", "0", "", "", "1", "1", "1", "29.3", "36.6", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "148", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.4", "90.5", "", "", "", "", "89.7"]} +{"pcdb_id": 1869, "brand_name": "Trianco", "model_name": "Eurostar", "model_qualifier": "70/90", "winter_efficiency_pct": 86.5, "summer_efficiency_pct": 74.8, "comparative_hot_water_efficiency_pct": 54.7, "output_kw_max": 26.3, "final_year_of_manufacture": 2003, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001869", "000062", "0", "2012/Mar/27 10:12", "Trianco Redfyre", "Trianco", "Eurostar", "70/90", "13961/2", "1997", "2003", "4", "1", "2", "1", "0", "", "", "1", "1", "1", "20.5", "26.3", "", "", "86.5", "74.8", "", "54.7", "", "2", "", "", "201", "1", "1", "148", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.9", "88.8", "", "", "", "", "88.3"]} +{"pcdb_id": 1870, "brand_name": "Trianco", "model_name": "Eurostar", "model_qualifier": "160/180", "winter_efficiency_pct": 86.3, "summer_efficiency_pct": 74.6, "comparative_hot_water_efficiency_pct": 54.5, "output_kw_max": 52.7, "final_year_of_manufacture": 2003, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001870", "000062", "0", "2012/Mar/27 10:12", "Trianco Redfyre", "Trianco", "Eurostar", "160/180", "13161/5", "1998", "2003", "4", "1", "2", "1", "0", "", "", "1", "1", "1", "46.9", "52.7", "", "", "86.3", "74.6", "", "54.5", "", "2", "", "", "201", "1", "1", "148", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.8", "86.8", "", "", "", "", "86.6"]} +{"pcdb_id": 1871, "brand_name": "Trianco", "model_name": "Eurostar", "model_qualifier": "50/70 W.M", "winter_efficiency_pct": 84.5, "summer_efficiency_pct": 72.8, "comparative_hot_water_efficiency_pct": 53.2, "output_kw_max": 20.5, "final_year_of_manufacture": 2003, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001871", "000062", "0", "2012/Mar/27 10:12", "Trianco Redfyre", "Trianco", "Eurostar", "50/70 W.M", "13961/12", "1996", "2003", "4", "2", "1", "1", "0", "", "", "1", "2", "1", "14.65", "20.5", "", "", "84.5", "72.8", "", "53.2", "", "2", "", "", "201", "1", "1", "148", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "83.7", "85.4", "", "", "", "", "85.0"]} +{"pcdb_id": 1872, "brand_name": "HRM Boilers", "model_name": "Wallstar", "model_qualifier": "12/14", "winter_efficiency_pct": 85.1, "summer_efficiency_pct": 73.4, "comparative_hot_water_efficiency_pct": 53.6, "output_kw_max": 15.35, "final_year_of_manufacture": 2006, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001872", "000098", "0", "2012/Mar/27 10:12", "HRM Boilers", "HRM Boilers", "Wallstar", "12/14", "12/14", "1989", "2006", "4", "2", "2", "1", "0", "", "", "1", "2", "1", "12", "15.35", "", "", "85.1", "73.4", "", "53.6", "", "2", "", "", "201", "1", "1", "115", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "83.1", "88.0", "", "", "", "", "87.1"]} +{"pcdb_id": 1873, "brand_name": "HRM Boilers", "model_name": "Wallstar", "model_qualifier": "15/19", "winter_efficiency_pct": 82.9, "summer_efficiency_pct": 71.2, "comparative_hot_water_efficiency_pct": 52.0, "output_kw_max": 19.4, "final_year_of_manufacture": 2006, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001873", "000098", "0", "2012/Mar/27 10:12", "HRM Boilers", "HRM Boilers", "Wallstar", "15/19", "15/19", "1995", "2006", "4", "2", "2", "1", "0", "", "", "1", "2", "1", "15", "19.4", "", "", "82.9", "71.2", "", "52.0", "", "2", "", "", "201", "1", "1", "115", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.1", "83.7", "", "", "", "", "83.4"]} +{"pcdb_id": 1874, "brand_name": "HRM Boilers", "model_name": "Wallstar", "model_qualifier": "20/24", "winter_efficiency_pct": 82.5, "summer_efficiency_pct": 70.8, "comparative_hot_water_efficiency_pct": 51.8, "output_kw_max": 24.65, "final_year_of_manufacture": 2006, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001874", "000098", "0", "2012/Mar/27 10:12", "HRM Boilers", "HRM Boilers", "Wallstar", "20/24", "20/24", "1997", "2006", "4", "2", "2", "1", "0", "", "", "1", "2", "1", "20", "24.65", "", "", "82.5", "70.8", "", "51.8", "", "2", "", "", "201", "1", "1", "115", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "84.0", "81.1", "", "", "", "", "81.6"]} +{"pcdb_id": 1875, "brand_name": "HRM Boilers", "model_name": "Starflow", "model_qualifier": "50/85", "winter_efficiency_pct": 84.5, "summer_efficiency_pct": 72.8, "comparative_hot_water_efficiency_pct": 53.2, "output_kw_max": 23.45, "final_year_of_manufacture": 2006, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001875", "000098", "0", "2012/Mar/27 10:12", "HRM Boilers", "HRM Boilers", "Starflow", "50/85", "50/85", "1997", "2006", "4", "1", "1", "1", "0", "", "", "1", "2", "1", "14.85", "23.45", "", "", "84.5", "72.8", "", "53.2", "", "2", "", "", "201", "1", "1", "115", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.7", "83.2", "", "", "", "", "83.7"]} +{"pcdb_id": 1876, "brand_name": "HRM Boilers", "model_name": "Starflow", "model_qualifier": "85/110", "winter_efficiency_pct": 81.1, "summer_efficiency_pct": 69.4, "comparative_hot_water_efficiency_pct": 50.7, "output_kw_max": 30.7, "final_year_of_manufacture": 2006, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001876", "000098", "0", "2012/Mar/27 10:12", "HRM Boilers", "HRM Boilers", "Starflow", "85/110", "85/110", "1997", "2006", "4", "1", "1", "1", "0", "", "", "1", "2", "1", "24.91", "30.7", "", "", "81.1", "69.4", "", "50.7", "", "2", "", "", "201", "1", "1", "115", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.9", "79.2", "", "", "", "", "79.9"]} +{"pcdb_id": 1877, "brand_name": "Trianco", "model_name": "Eurostar Utility", "model_qualifier": "50/65 13961/1", "winter_efficiency_pct": 82.2, "summer_efficiency_pct": 70.5, "comparative_hot_water_efficiency_pct": 51.5, "output_kw_max": 19.0, "final_year_of_manufacture": 2003, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001877", "000062", "0", "2012/Mar/27 10:12", "Trianco Redfyre", "Trianco", "Eurostar Utility", "50/65 13961/1", "", "1997", "2003", "4", "1", "2", "1", "0", "", "", "1", "1", "1", "14.65", "19.0", "", "", "82.2", "70.5", "", "51.5", "", "2", "", "", "201", "1", "1", "148", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.4", "82.0", "", "", "", "", "82.1"]} +{"pcdb_id": 1878, "brand_name": "Trianco", "model_name": "Eurostar", "model_qualifier": "50/65 System", "winter_efficiency_pct": 82.2, "summer_efficiency_pct": 70.5, "comparative_hot_water_efficiency_pct": 51.5, "output_kw_max": 19.0, "final_year_of_manufacture": 2003, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001878", "000062", "0", "2012/Mar/27 10:12", "Trianco Redfyre", "Trianco", "Eurostar", "50/65 System", "13961/1", "1997", "2003", "4", "1", "2", "1", "0", "", "", "1", "1", "1", "14.65", "19.0", "", "", "82.2", "70.5", "", "51.5", "", "2", "", "", "201", "1", "1", "148", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.4", "82.0", "", "", "", "", "82.1"]} +{"pcdb_id": 1879, "brand_name": "Trianco", "model_name": "Eurostar", "model_qualifier": "70/90 Utility", "winter_efficiency_pct": 86.5, "summer_efficiency_pct": 74.8, "comparative_hot_water_efficiency_pct": 54.7, "output_kw_max": 26.3, "final_year_of_manufacture": 2003, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001879", "000062", "0", "2012/Mar/27 10:12", "Trianco Redfyre", "Trianco", "Eurostar", "70/90 Utility", "13961/2", "1997", "2003", "4", "1", "2", "1", "0", "", "", "1", "1", "1", "20.5", "26.3", "", "", "86.5", "74.8", "", "54.7", "", "2", "", "", "201", "1", "1", "148", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.9", "88.8", "", "", "", "", "88.3"]} +{"pcdb_id": 1880, "brand_name": "Trianco", "model_name": "Eurostar", "model_qualifier": "70/90 System", "winter_efficiency_pct": 86.5, "summer_efficiency_pct": 74.8, "comparative_hot_water_efficiency_pct": 54.7, "output_kw_max": 26.3, "final_year_of_manufacture": 2003, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001880", "000062", "0", "2012/Mar/27 10:12", "Trianco Redfyre", "Trianco", "Eurostar", "70/90 System", "13961/2", "1997", "2003", "4", "1", "2", "1", "0", "", "", "1", "1", "1", "20.5", "26.3", "", "", "86.5", "74.8", "", "54.7", "", "2", "", "", "201", "1", "1", "148", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.9", "88.8", "", "", "", "", "88.3"]} +{"pcdb_id": 1915, "brand_name": "Ravenheat", "model_name": "CSI 85", "model_qualifier": "", "winter_efficiency_pct": 86.3, "summer_efficiency_pct": 77.7, "comparative_hot_water_efficiency_pct": 54.7, "output_kw_max": 25.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001915", "000026", "0", "2006/Jan/17 12:31", "Ravenheat", "Ravenheat", "CSI 85", "", "GC No. 47 581 19", "1998", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "25.6", "25.6", "", "", "86.3", "77.7", "", "54.7", "", "2", "", "", "104", "1", "2", "140", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.2", "92.9", "", "", "", "", "91.8"]} +{"pcdb_id": 1916, "brand_name": "Ravenheat", "model_name": "RSF 25/20E", "model_qualifier": "", "winter_efficiency_pct": 77.4, "summer_efficiency_pct": 67.3, "comparative_hot_water_efficiency_pct": 47.3, "output_kw_max": 29.0, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001916", "000026", "0", "2006/Jan/17 12:55", "Ravenheat", "Ravenheat", "RSF 25/20E", "", "GC No. 47 581 09", "1996", "2001", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "29", "29", "", "", "77.4", "67.3", "", "47.3", "", "2", "", "", "104", "1", "2", "140", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "79.3", "77.8", "", "", "", "", "78.1"]} +{"pcdb_id": 1917, "brand_name": "Ravenheat", "model_name": "RSF 25/20ET", "model_qualifier": "", "winter_efficiency_pct": 77.4, "summer_efficiency_pct": 67.3, "comparative_hot_water_efficiency_pct": 47.3, "output_kw_max": 29.0, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001917", "000026", "0", "2006/Jan/17 12:55", "Ravenheat", "Ravenheat", "RSF 25/20ET", "", "GC No. 47 581 08", "1996", "2001", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "29", "29", "", "", "77.4", "67.3", "", "47.3", "", "2", "", "", "104", "1", "2", "140", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "79.3", "77.8", "", "", "", "", "78.1"]} +{"pcdb_id": 1918, "brand_name": "Ravenheat", "model_name": "RSF 20/20E", "model_qualifier": "", "winter_efficiency_pct": 78.0, "summer_efficiency_pct": 67.9, "comparative_hot_water_efficiency_pct": 47.8, "output_kw_max": 24.1, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001918", "000026", "0", "2006/Jan/17 12:55", "Ravenheat", "Ravenheat", "RSF 20/20E", "", "GC No. 47 581 07", "1996", "2001", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "24.1", "24.1", "", "", "78.0", "67.9", "", "47.8", "", "2", "", "", "104", "1", "2", "140", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "80.6", "77.8", "", "", "", "", "78.4"]} +{"pcdb_id": 1919, "brand_name": "Ravenheat", "model_name": "RSF 20/20ET", "model_qualifier": "", "winter_efficiency_pct": 78.0, "summer_efficiency_pct": 67.9, "comparative_hot_water_efficiency_pct": 47.8, "output_kw_max": 24.1, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001919", "000026", "0", "2006/Jan/17 12:55", "Ravenheat", "Ravenheat", "RSF 20/20ET", "", "GC No. 47 581 06", "1996", "2001", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "24.1", "24.1", "", "", "78.0", "67.9", "", "47.8", "", "2", "", "", "104", "1", "2", "140", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "80.6", "77.8", "", "", "", "", "78.4"]} +{"pcdb_id": 1920, "brand_name": "Ravenheat", "model_name": "CSI 85T", "model_qualifier": "", "winter_efficiency_pct": 86.3, "summer_efficiency_pct": 77.7, "comparative_hot_water_efficiency_pct": 54.7, "output_kw_max": 25.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001920", "000026", "0", "2006/Jan/17 12:31", "Ravenheat", "Ravenheat", "CSI 85T", "", "GC No. 47 581 20", "1998", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "25.6", "25.6", "", "", "86.3", "77.7", "", "54.7", "", "2", "", "", "104", "1", "2", "140", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.2", "92.9", "", "", "", "", "91.8"]} +{"pcdb_id": 1921, "brand_name": "Ravenheat", "model_name": "RSF 25/25E", "model_qualifier": "", "winter_efficiency_pct": 77.5, "summer_efficiency_pct": 67.4, "comparative_hot_water_efficiency_pct": 47.4, "output_kw_max": 29.0, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001921", "000026", "0", "2006/Jan/17 12:55", "Ravenheat", "Ravenheat", "RSF 25/25E", "", "GC No. 47 581 11", "1996", "2001", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "29", "29", "", "", "77.5", "67.4", "", "47.4", "", "2", "", "", "104", "1", "2", "140", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "79.6", "77.8", "", "", "", "", "78.2"]} +{"pcdb_id": 1922, "brand_name": "Ravenheat", "model_name": "RSF 25/25ET", "model_qualifier": "", "winter_efficiency_pct": 77.5, "summer_efficiency_pct": 67.4, "comparative_hot_water_efficiency_pct": 47.4, "output_kw_max": 29.0, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001922", "000026", "0", "2006/Jan/17 12:55", "Ravenheat", "Ravenheat", "RSF 25/25ET", "", "GC No. 47 581 10", "1996", "2001", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "29", "29", "", "", "77.5", "67.4", "", "47.4", "", "2", "", "", "104", "1", "2", "140", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "79.6", "77.8", "", "", "", "", "78.2"]} +{"pcdb_id": 1923, "brand_name": "Ravenheat", "model_name": "RSF 25/20E LPG", "model_qualifier": "", "winter_efficiency_pct": 79.1, "summer_efficiency_pct": 69.0, "comparative_hot_water_efficiency_pct": 48.5, "output_kw_max": 29.0, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001923", "000026", "0", "2006/Jan/17 12:55", "Ravenheat", "Ravenheat", "RSF 25/20E LPG", "", "GC No. 47 581 15", "1996", "2001", "2", "2", "1", "2", "0", "", "", "1", "2", "2", "29", "29", "", "", "79.1", "69.0", "", "48.5", "", "2", "0", "", "104", "1", "2", "140", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.0", "79.6", "", "", "", "", "79.9"]} +{"pcdb_id": 1924, "brand_name": "Ravenheat", "model_name": "RSF 25/20ET LPG", "model_qualifier": "", "winter_efficiency_pct": 79.1, "summer_efficiency_pct": 69.0, "comparative_hot_water_efficiency_pct": 48.5, "output_kw_max": 29.0, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001924", "000026", "0", "2006/Jan/17 12:55", "Ravenheat", "Ravenheat", "RSF 25/20ET LPG", "", "GC No. 47 581 14", "1996", "2001", "2", "2", "1", "2", "0", "", "", "1", "2", "2", "29", "29", "", "", "79.1", "69.0", "", "48.5", "", "2", "0", "", "104", "1", "2", "140", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.0", "79.6", "", "", "", "", "79.9"]} +{"pcdb_id": 1925, "brand_name": "Ravenheat", "model_name": "RSF 25/25ET LPG", "model_qualifier": "", "winter_efficiency_pct": 79.2, "summer_efficiency_pct": 69.1, "comparative_hot_water_efficiency_pct": 48.6, "output_kw_max": 29.0, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001925", "000026", "0", "2006/Jan/17 12:55", "Ravenheat", "Ravenheat", "RSF 25/25ET LPG", "", "GC No. 47 581 16", "1996", "2001", "2", "2", "1", "2", "0", "", "", "1", "2", "2", "29", "29", "", "", "79.2", "69.1", "", "48.6", "", "2", "0", "", "104", "1", "2", "140", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.3", "79.6", "", "", "", "", "79.9"]} +{"pcdb_id": 1926, "brand_name": "Ravenheat", "model_name": "RSF 25/25E LPG", "model_qualifier": "", "winter_efficiency_pct": 79.2, "summer_efficiency_pct": 69.1, "comparative_hot_water_efficiency_pct": 48.6, "output_kw_max": 29.0, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001926", "000026", "0", "2006/Jan/17 12:55", "Ravenheat", "Ravenheat", "RSF 25/25E LPG", "", "GC No. 47 581 17", "1996", "2001", "2", "2", "1", "2", "0", "", "", "1", "2", "2", "29", "29", "", "", "79.2", "69.1", "", "48.6", "", "2", "0", "", "104", "1", "2", "140", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.3", "79.6", "", "", "", "", "79.9"]} +{"pcdb_id": 1927, "brand_name": "Ravenheat", "model_name": "RSF 20/20E LPG", "model_qualifier": "", "winter_efficiency_pct": 79.8, "summer_efficiency_pct": 69.7, "comparative_hot_water_efficiency_pct": 49.0, "output_kw_max": 24.1, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001927", "000026", "0", "2006/Jan/17 12:55", "Ravenheat", "Ravenheat", "RSF 20/20E LPG", "", "GC No. 47 581 13", "1996", "2001", "2", "2", "1", "2", "0", "", "", "1", "2", "2", "24.1", "24.1", "", "", "79.8", "69.7", "", "49.0", "", "2", "0", "", "104", "1", "2", "140", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.4", "79.6", "", "", "", "", "80.1"]} +{"pcdb_id": 1928, "brand_name": "Ravenheat", "model_name": "RSF 20/20ET LPG", "model_qualifier": "", "winter_efficiency_pct": 79.8, "summer_efficiency_pct": 69.7, "comparative_hot_water_efficiency_pct": 49.0, "output_kw_max": 24.1, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001928", "000026", "0", "2006/Jan/17 12:55", "Ravenheat", "Ravenheat", "RSF 20/20ET LPG", "", "GC No. 47 581 12", "1996", "2001", "2", "2", "1", "2", "0", "", "", "1", "2", "2", "24.1", "24.1", "", "", "79.8", "69.7", "", "49.0", "", "2", "0", "", "104", "1", "2", "140", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.4", "79.6", "", "", "", "", "80.1"]} +{"pcdb_id": 1929, "brand_name": "Ravenheat", "model_name": "RSF 100ET LPG", "model_qualifier": "", "winter_efficiency_pct": 79.2, "summer_efficiency_pct": 69.1, "comparative_hot_water_efficiency_pct": 48.6, "output_kw_max": 29.0, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001929", "000026", "0", "2006/Jan/17 12:55", "Ravenheat", "Ravenheat", "RSF 100ET LPG", "", "GC No. 47 581 26A", "1999", "2001", "2", "2", "1", "2", "0", "", "", "1", "2", "2", "29", "29", "", "", "79.2", "69.1", "", "48.6", "", "2", "0", "", "104", "1", "2", "140", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.3", "79.6", "", "", "", "", "79.9"]} +{"pcdb_id": 1930, "brand_name": "Ravenheat", "model_name": "RSF 100E LPG", "model_qualifier": "", "winter_efficiency_pct": 79.2, "summer_efficiency_pct": 69.1, "comparative_hot_water_efficiency_pct": 48.6, "output_kw_max": 29.0, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001930", "000026", "0", "2006/Jan/17 12:55", "Ravenheat", "Ravenheat", "RSF 100E LPG", "", "GC No. 47 581 25A", "1999", "2001", "2", "2", "1", "2", "0", "", "", "1", "2", "2", "29.0", "29.0", "", "", "79.2", "69.1", "", "48.6", "", "2", "0", "", "104", "1", "2", "140", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.3", "79.6", "", "", "", "", "79.9"]} +{"pcdb_id": 1931, "brand_name": "Ravenheat", "model_name": "RSF 84E LPG", "model_qualifier": "", "winter_efficiency_pct": 79.8, "summer_efficiency_pct": 69.7, "comparative_hot_water_efficiency_pct": 49.0, "output_kw_max": 24.1, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001931", "000026", "0", "2006/Jan/17 12:55", "Ravenheat", "Ravenheat", "RSF 84E LPG", "", "GC No. 47 581 27A", "1999", "2001", "2", "2", "1", "2", "0", "", "", "1", "2", "2", "24.1", "24.1", "", "", "79.8", "69.7", "", "49.0", "", "2", "0", "", "104", "1", "2", "140", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.4", "79.6", "", "", "", "", "80.1"]} +{"pcdb_id": 1932, "brand_name": "Ravenheat", "model_name": "RSF 84ET LPG", "model_qualifier": "", "winter_efficiency_pct": 79.8, "summer_efficiency_pct": 69.7, "comparative_hot_water_efficiency_pct": 49.0, "output_kw_max": 24.1, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001932", "000026", "0", "2006/Jan/17 12:55", "Ravenheat", "Ravenheat", "RSF 84ET LPG", "", "GC No. 47 581 28A", "1999", "2001", "2", "2", "1", "2", "0", "", "", "1", "2", "2", "24.1", "24.1", "", "", "79.8", "69.7", "", "49.0", "", "2", "0", "", "104", "1", "2", "140", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.4", "79.6", "", "", "", "", "80.1"]} +{"pcdb_id": 1933, "brand_name": "Ravenheat", "model_name": "RSF 820/20", "model_qualifier": "", "winter_efficiency_pct": 75.4, "summer_efficiency_pct": 65.3, "comparative_hot_water_efficiency_pct": 45.9, "output_kw_max": 23.6, "final_year_of_manufacture": 2002, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001933", "000026", "0", "2006/Jan/17 12:55", "Ravenheat", "Ravenheat", "RSF 820/20", "", "GC No. 47 581 01", "1997", "2002", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "23.6", "23.6", "", "", "75.4", "65.3", "", "45.9", "", "2", "", "", "104", "2", "2", "140", "20", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.3", "79.9", "", "", "", "", "80.2"]} +{"pcdb_id": 1934, "brand_name": "Ravenheat", "model_name": "RSF 820/20T", "model_qualifier": "", "winter_efficiency_pct": 75.4, "summer_efficiency_pct": 65.3, "comparative_hot_water_efficiency_pct": 45.9, "output_kw_max": 23.6, "final_year_of_manufacture": 2002, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001934", "000026", "0", "2006/Jan/17 12:55", "Ravenheat", "Ravenheat", "RSF 820/20T", "", "GC No. 47 581 05", "1997", "2002", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "23.6", "23.6", "", "", "75.4", "65.3", "", "45.9", "", "2", "", "", "104", "2", "2", "140", "20", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.3", "79.9", "", "", "", "", "80.2"]} +{"pcdb_id": 1935, "brand_name": "Ravenheat", "model_name": "RSF 100E", "model_qualifier": "", "winter_efficiency_pct": 77.5, "summer_efficiency_pct": 67.4, "comparative_hot_water_efficiency_pct": 47.4, "output_kw_max": 29.0, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001935", "000026", "0", "2006/Jan/17 12:55", "Ravenheat", "Ravenheat", "RSF 100E", "", "GC No. 47 581 25A", "1999", "2001", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "29.0", "29.0", "", "", "77.5", "67.4", "", "47.4", "", "2", "", "", "104", "1", "2", "140", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "79.6", "77.8", "", "", "", "", "78.2"]} +{"pcdb_id": 1936, "brand_name": "Ravenheat", "model_name": "RSF 100ET", "model_qualifier": "", "winter_efficiency_pct": 77.5, "summer_efficiency_pct": 67.4, "comparative_hot_water_efficiency_pct": 47.4, "output_kw_max": 29.0, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001936", "000026", "0", "2006/Jan/17 12:55", "Ravenheat", "Ravenheat", "RSF 100ET", "", "GC No. 47 581 26A", "1999", "2001", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "29.0", "29.0", "", "", "77.5", "67.4", "", "47.4", "", "2", "", "", "104", "1", "2", "140", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "79.6", "77.8", "", "", "", "", "78.2"]} +{"pcdb_id": 1937, "brand_name": "Ravenheat", "model_name": "CSI 85T LPG", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 56.1, "output_kw_max": 25.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001937", "000026", "0", "2006/Jan/17 12:31", "Ravenheat", "Ravenheat", "CSI 85T LPG", "", "GC No. 47 581 24", "1998", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "25.6", "25.6", "", "", "88.3", "79.7", "", "56.1", "", "2", "0", "", "104", "1", "2", "140", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.2", "95.0", "", "", "", "", "93.9"]} +{"pcdb_id": 1938, "brand_name": "Ravenheat", "model_name": "CSI 85 LPG", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 56.1, "output_kw_max": 25.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001938", "000026", "0", "2006/Jan/17 12:31", "Ravenheat", "Ravenheat", "CSI 85 LPG", "", "GC No. 47 581 23", "1998", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "25.6", "25.6", "", "", "88.3", "79.7", "", "56.1", "", "2", "0", "", "104", "1", "2", "140", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.2", "95.0", "", "", "", "", "93.9"]} +{"pcdb_id": 1939, "brand_name": "Ravenheat", "model_name": "RSF 84E", "model_qualifier": "", "winter_efficiency_pct": 78.0, "summer_efficiency_pct": 67.9, "comparative_hot_water_efficiency_pct": 47.8, "output_kw_max": 24.1, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001939", "000026", "0", "2006/Jan/17 12:55", "Ravenheat", "Ravenheat", "RSF 84E", "", "GC No. 47 581 27A", "1999", "2001", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "24.1", "24.1", "", "", "78.0", "67.9", "", "47.8", "", "2", "", "", "104", "1", "2", "140", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "80.6", "77.8", "", "", "", "", "78.4"]} +{"pcdb_id": 1940, "brand_name": "Ravenheat", "model_name": "RSF 84 ET", "model_qualifier": "", "winter_efficiency_pct": 78.0, "summer_efficiency_pct": 67.9, "comparative_hot_water_efficiency_pct": 47.8, "output_kw_max": 24.1, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001940", "000026", "0", "2006/Jan/17 12:55", "Ravenheat", "Ravenheat", "RSF 84 ET", "", "GC No. 47 581 28A", "1999", "2001", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "24.1", "24.1", "", "", "78.0", "67.9", "", "47.8", "", "2", "", "", "104", "1", "2", "140", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "80.6", "77.8", "", "", "", "", "78.4"]} +{"pcdb_id": 1941, "brand_name": "Ravenheat", "model_name": "RSF 82 E", "model_qualifier": "", "winter_efficiency_pct": 79.4, "summer_efficiency_pct": 69.3, "comparative_hot_water_efficiency_pct": 48.7, "output_kw_max": 23.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001941", "000026", "0", "2006/Jan/17 12:31", "Ravenheat", "Ravenheat", "RSF 82 E", "", "GC No. 47 581 18", "1998", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "23.6", "23.6", "", "", "79.4", "69.3", "", "48.7", "", "2", "", "", "104", "1", "2", "140", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.3", "79.9", "", "", "", "", "80.2"]} +{"pcdb_id": 1942, "brand_name": "Ravenheat", "model_name": "RSF 82 ET", "model_qualifier": "", "winter_efficiency_pct": 79.4, "summer_efficiency_pct": 69.3, "comparative_hot_water_efficiency_pct": 48.7, "output_kw_max": 23.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001942", "000026", "0", "2006/Jan/17 12:31", "Ravenheat", "Ravenheat", "RSF 82 ET", "", "GC No. 47 581 04", "1998", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "23.6", "23.6", "", "", "79.4", "69.3", "", "48.7", "", "2", "", "", "104", "1", "2", "140", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.3", "79.9", "", "", "", "", "80.2"]} +{"pcdb_id": 1943, "brand_name": "Ravenheat", "model_name": "CSI System T", "model_qualifier": "", "winter_efficiency_pct": 86.3, "summer_efficiency_pct": 77.3, "comparative_hot_water_efficiency_pct": 56.5, "output_kw_max": 25.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001943", "000026", "0", "2012/Mar/27 10:12", "Ravenheat", "Ravenheat", "CSI System T", "", "GC No. 5158102CSI", "1999", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "25.6", "25.6", "", "", "86.3", "77.3", "", "56.5", "", "2", "", "", "102", "1", "2", "140", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.2", "92.9", "", "", "", "", "91.8"]} +{"pcdb_id": 1944, "brand_name": "Ravenheat", "model_name": "CSI System", "model_qualifier": "", "winter_efficiency_pct": 86.3, "summer_efficiency_pct": 77.3, "comparative_hot_water_efficiency_pct": 56.5, "output_kw_max": 25.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001944", "000026", "0", "2012/Mar/27 10:12", "Ravenheat", "Ravenheat", "CSI System", "", "GC No. 4158101CSI", "1999", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "25.6", "25.6", "", "", "86.3", "77.3", "", "56.5", "", "2", "", "", "102", "1", "2", "140", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.2", "92.9", "", "", "", "", "91.8"]} +{"pcdb_id": 1945, "brand_name": "Ravenheat", "model_name": "CSI Primary LPG", "model_qualifier": "", "winter_efficiency_pct": 86.9, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 25.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001945", "000026", "0", "2012/Mar/27 10:12", "Ravenheat", "Ravenheat", "CSI Primary LPG", "", "GC No. 4158106CSI", "1999", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "11.7", "25.6", "", "", "86.9", "79.3", "", "57.9", "", "2", "0", "", "101", "1", "1", "60", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "89.2", "95.0", "", "", "", "", "93.9"]} +{"pcdb_id": 1946, "brand_name": "Ravenheat", "model_name": "CSI Primary", "model_qualifier": "", "winter_efficiency_pct": 84.9, "summer_efficiency_pct": 77.3, "comparative_hot_water_efficiency_pct": 56.5, "output_kw_max": 25.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001946", "000026", "0", "2012/Mar/27 10:12", "Ravenheat", "Ravenheat", "CSI Primary", "", "GC No. 4158105CSI", "1999", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "11.7", "25.6", "", "", "84.9", "77.3", "", "56.5", "", "2", "", "", "101", "1", "1", "60", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "87.2", "92.9", "", "", "", "", "91.8"]} +{"pcdb_id": 1947, "brand_name": "Ravenheat", "model_name": "CSI System T", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 25.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001947", "000026", "0", "2012/Mar/27 10:12", "Ravenheat", "Ravenheat", "CSI System T", "", "GC No. 4158104CSI(T)", "1999", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "25.6", "25.6", "", "", "88.3", "79.3", "", "57.9", "", "2", "0", "", "102", "1", "2", "140", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.2", "95.0", "", "", "", "", "93.9"]} +{"pcdb_id": 1948, "brand_name": "Ravenheat", "model_name": "CSI System", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 25.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001948", "000026", "0", "2012/Mar/27 10:12", "Ravenheat", "Ravenheat", "CSI System", "", "GC No. 4158103CSI", "1999", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "25.6", "25.6", "", "", "88.3", "79.3", "", "57.9", "", "2", "0", "", "102", "1", "2", "140", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.2", "95.0", "", "", "", "", "93.9"]} +{"pcdb_id": 1949, "brand_name": "Potterton Myson", "model_name": "Combi 100", "model_qualifier": "", "winter_efficiency_pct": 79.7, "summer_efficiency_pct": 69.6, "comparative_hot_water_efficiency_pct": 48.9, "output_kw_max": 29.0, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001949", "000005", "0", "2006/Jan/17 12:55", "Potterton Myson", "Potterton Myson", "Combi 100", "", "LRR", "1999", "2001", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "29.0", "29.0", "", "", "79.7", "69.6", "", "48.9", "", "2", "", "", "104", "1", "2", "200", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.2", "80.5", "", "", "", "", "80.7"]} +{"pcdb_id": 1951, "brand_name": "Potterton Myson", "model_name": "Envoy 30", "model_qualifier": "", "winter_efficiency_pct": 85.6, "summer_efficiency_pct": 78.0, "comparative_hot_water_efficiency_pct": 57.0, "output_kw_max": 9.7, "final_year_of_manufacture": 2000, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001951", "000005", "0", "2012/Mar/27 10:12", "Potterton Myson", "Potterton Myson", "Envoy 30", "", "HKA", "1995", "2000", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "9.7", "9.7", "", "", "85.6", "78.0", "", "57.0", "", "2", "", "", "101", "1", "1", "80", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "87.5", "94.5", "", "", "", "", "93.2"]} +{"pcdb_id": 1952, "brand_name": "Potterton Myson", "model_name": "Envoy 40", "model_qualifier": "", "winter_efficiency_pct": 85.5, "summer_efficiency_pct": 77.9, "comparative_hot_water_efficiency_pct": 56.9, "output_kw_max": 12.8, "final_year_of_manufacture": 2000, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001952", "000005", "0", "2012/Mar/27 10:12", "Potterton Myson", "Potterton Myson", "Envoy 40", "", "HKB", "1995", "2000", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "12.8", "12.8", "", "", "85.5", "77.9", "", "56.9", "", "2", "", "", "101", "1", "1", "80", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "87.8", "94.0", "", "", "", "", "92.8"]} +{"pcdb_id": 1953, "brand_name": "Potterton Myson", "model_name": "Envoy 50", "model_qualifier": "", "winter_efficiency_pct": 85.5, "summer_efficiency_pct": 77.9, "comparative_hot_water_efficiency_pct": 56.9, "output_kw_max": 16.1, "final_year_of_manufacture": 2000, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001953", "000005", "0", "2012/Mar/27 10:12", "Potterton Myson", "Potterton Myson", "Envoy 50", "", "HKC", "1995", "2000", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "16.1", "16.1", "", "", "85.5", "77.9", "", "56.9", "", "2", "", "", "101", "1", "1", "80", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "88.0", "94.0", "", "", "", "", "92.8"]} +{"pcdb_id": 1954, "brand_name": "Potterton Myson", "model_name": "Envoy 60", "model_qualifier": "", "winter_efficiency_pct": 85.2, "summer_efficiency_pct": 77.6, "comparative_hot_water_efficiency_pct": 56.7, "output_kw_max": 19.0, "final_year_of_manufacture": 2000, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001954", "000005", "0", "2012/Mar/27 10:12", "Potterton Myson", "Potterton Myson", "Envoy 60", "", "HKD", "1995", "2000", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "19.0", "19.0", "", "", "85.2", "77.6", "", "56.7", "", "2", "", "", "101", "1", "1", "80", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "86.8", "93.8", "", "", "", "", "92.5"]} +{"pcdb_id": 1955, "brand_name": "Potterton Myson", "model_name": "Envoy 80", "model_qualifier": "", "winter_efficiency_pct": 85.1, "summer_efficiency_pct": 77.5, "comparative_hot_water_efficiency_pct": 56.6, "output_kw_max": 25.0, "final_year_of_manufacture": 2000, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001955", "000005", "0", "2012/Mar/27 10:12", "Potterton Myson", "Potterton Myson", "Envoy 80", "", "HKE", "1995", "2000", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "25.0", "25.0", "", "", "85.1", "77.5", "", "56.6", "", "2", "", "", "101", "1", "1", "80", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "87.4", "93.3", "", "", "", "", "92.2"]} +{"pcdb_id": 1964, "brand_name": "Potterton", "model_name": "Profile", "model_qualifier": "40e", "winter_efficiency_pct": 72.7, "summer_efficiency_pct": 62.6, "comparative_hot_water_efficiency_pct": 45.7, "output_kw_max": 11.72, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001964", "000005", "0", "2012/Mar/27 10:12", "Potterton Myson", "Potterton", "Profile", "40e", "HBS", "1988", "2001", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "8.79", "11.72", "", "", "72.7", "62.6", "", "45.7", "", "2", "", "", "101", "1", "1", "80", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "74.9", "73.7", "", "", "", "", "73.9"]} +{"pcdb_id": 1965, "brand_name": "Potterton", "model_name": "Profile", "model_qualifier": "50e", "winter_efficiency_pct": 76.3, "summer_efficiency_pct": 66.2, "comparative_hot_water_efficiency_pct": 48.4, "output_kw_max": 14.65, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001965", "000005", "0", "2012/Mar/27 10:12", "Potterton Myson", "Potterton", "Profile", "50e", "HBT", "1988", "2001", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "11.72", "14.65", "", "", "76.3", "66.2", "", "48.4", "", "2", "", "", "101", "1", "1", "80", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "78.6", "77.2", "", "", "", "", "77.5"]} +{"pcdb_id": 1966, "brand_name": "Potterton", "model_name": "Profile", "model_qualifier": "60e", "winter_efficiency_pct": 76.0, "summer_efficiency_pct": 65.9, "comparative_hot_water_efficiency_pct": 48.2, "output_kw_max": 17.58, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001966", "000005", "0", "2012/Mar/27 10:12", "Potterton Myson", "Potterton", "Profile", "60e", "HBU", "1988", "2001", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "14.65", "17.58", "", "", "76.0", "65.9", "", "48.2", "", "2", "", "", "101", "1", "1", "80", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "78.3", "76.9", "", "", "", "", "77.2"]} +{"pcdb_id": 1967, "brand_name": "Potterton", "model_name": "Profile", "model_qualifier": "80e", "winter_efficiency_pct": 75.3, "summer_efficiency_pct": 65.2, "comparative_hot_water_efficiency_pct": 47.6, "output_kw_max": 23.45, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001967", "000005", "0", "2012/Mar/27 10:12", "Potterton Myson", "Potterton", "Profile", "80e", "HBV", "1988", "2001", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "17.58", "23.45", "", "", "75.3", "65.2", "", "47.6", "", "2", "", "", "101", "1", "1", "80", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "77.4", "76.4", "", "", "", "", "76.6"]} +{"pcdb_id": 1968, "brand_name": "Potterton", "model_name": "Profile", "model_qualifier": "100e", "winter_efficiency_pct": 74.8, "summer_efficiency_pct": 64.7, "comparative_hot_water_efficiency_pct": 47.3, "output_kw_max": 29.3, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001968", "000005", "0", "2012/Mar/27 10:12", "Potterton Myson", "Potterton", "Profile", "100e", "HHF", "1988", "2001", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "23.5", "29.3", "", "", "74.8", "64.7", "", "47.3", "", "2", "", "", "101", "1", "1", "80", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "76.9", "75.9", "", "", "", "", "76.1"]} +{"pcdb_id": 1973, "brand_name": "Potterton Myson", "model_name": "British Gas 30F2", "model_qualifier": "", "winter_efficiency_pct": 76.1, "summer_efficiency_pct": 66.0, "comparative_hot_water_efficiency_pct": 48.2, "output_kw_max": 8.79, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001973", "000005", "0", "2012/Mar/27 10:12", "Potterton Myson", "Potterton Myson", "British Gas 30F2", "", "LRV", "1999", "2001", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "5.86", "8.79", "", "", "76.1", "66.0", "", "48.2", "", "2", "", "", "101", "1", "1", "80", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "78.6", "76.8", "", "", "", "", "77.1"]} +{"pcdb_id": 1974, "brand_name": "Potterton Myson", "model_name": "British Gas 40F2", "model_qualifier": "", "winter_efficiency_pct": 77.2, "summer_efficiency_pct": 67.1, "comparative_hot_water_efficiency_pct": 49.0, "output_kw_max": 11.72, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001974", "000005", "0", "2012/Mar/27 10:12", "Potterton Myson", "Potterton Myson", "British Gas 40F2", "", "LRW", "1999", "2001", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "8.79", "11.72", "", "", "77.2", "67.1", "", "49.0", "", "2", "", "", "101", "1", "1", "80", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.6", "78.0", "", "", "", "", "78.3"]} +{"pcdb_id": 1975, "brand_name": "Potterton Myson", "model_name": "British Gas 50F2", "model_qualifier": "", "winter_efficiency_pct": 77.6, "summer_efficiency_pct": 67.5, "comparative_hot_water_efficiency_pct": 49.3, "output_kw_max": 14.65, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001975", "000005", "0", "2012/Mar/27 10:12", "Potterton Myson", "Potterton Myson", "British Gas 50F2", "", "LRX", "1999", "2001", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "11.72", "14.65", "", "", "77.6", "67.5", "", "49.3", "", "2", "", "", "101", "1", "1", "80", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "80.2", "78.3", "", "", "", "", "78.7"]} +{"pcdb_id": 1976, "brand_name": "Potterton Myson", "model_name": "British Gas 60F2", "model_qualifier": "", "winter_efficiency_pct": 77.6, "summer_efficiency_pct": 67.5, "comparative_hot_water_efficiency_pct": 49.3, "output_kw_max": 17.58, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001976", "000005", "0", "2012/Mar/27 10:12", "Potterton Myson", "Potterton Myson", "British Gas 60F2", "", "LRY", "1999", "2001", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "14.65", "17.58", "", "", "77.6", "67.5", "", "49.3", "", "2", "", "", "101", "1", "1", "80", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "80.0", "78.4", "", "", "", "", "78.7"]} +{"pcdb_id": 1977, "brand_name": "Potterton Myson", "model_name": "British Gas 80F2", "model_qualifier": "", "winter_efficiency_pct": 76.8, "summer_efficiency_pct": 66.7, "comparative_hot_water_efficiency_pct": 48.7, "output_kw_max": 23.45, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001977", "000005", "0", "2012/Mar/27 10:12", "Potterton Myson", "Potterton Myson", "British Gas 80F2", "", "LSA", "1999", "2001", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "17.58", "23.45", "", "", "76.8", "66.7", "", "48.7", "", "2", "", "", "101", "1", "1", "80", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.2", "77.6", "", "", "", "", "77.9"]} +{"pcdb_id": 1978, "brand_name": "Powermax", "model_name": "185", "model_qualifier": "", "winter_efficiency_pct": 83.5, "summer_efficiency_pct": 81.6, "comparative_hot_water_efficiency_pct": 62.0, "output_kw_max": 18.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 3, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001978", "000099", "0", "2002/Aug/14 10:19", "Range Powermax", "Powermax", "185", "", "87AQ149", "1993", "current", "1", "1", "1", "3", "0", "", "", "1", "2", "2", "18.3", "18.3", "", "", "83.5", "81.6", "", "62.0", "", "2", "", "", "107", "1", "1", "140", "0", "3", "", "0", "150", "0", "50", "5", "80", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.8", "85.0", "", "", "", "", "84.6"]} +{"pcdb_id": 1979, "brand_name": "Potterton Myson", "model_name": "Kingfisher Mf RS 100", "model_qualifier": "", "winter_efficiency_pct": 77.8, "summer_efficiency_pct": 67.7, "comparative_hot_water_efficiency_pct": 49.5, "output_kw_max": 29.31, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001979", "000005", "0", "2012/Mar/27 10:12", "Potterton Myson", "Potterton Myson", "Kingfisher Mf RS 100", "", "HLX", "1997", "2001", "1", "1", "1", "1", "0", "", "", "1", "2", "2", "26.38", "29.31", "", "", "77.8", "67.7", "", "49.5", "", "2", "", "", "101", "1", "1", "80", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.2", "79.6", "", "", "", "", "79.6"]} +{"pcdb_id": 1980, "brand_name": "Powermax", "model_name": "155", "model_qualifier": "", "winter_efficiency_pct": 81.2, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 63.9, "output_kw_max": 15.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 3, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001980", "000099", "0", "2002/Aug/14 10:05", "Range Powermax", "Powermax", "155", "", "87AQ147", "1996", "current", "1", "1", "1", "3", "0", "", "", "1", "2", "2", "15.5", "15.5", "", "", "81.2", "79.3", "", "63.9", "", "2", "", "", "107", "1", "1", "140", "0", "3", "", "0", "100", "0", "50", "5", "80", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "80.7", "82.0", "", "", "", "", "81.8"]} +{"pcdb_id": 1981, "brand_name": "Potterton Myson", "model_name": "Kingfisher Mf RS 90", "model_qualifier": "", "winter_efficiency_pct": 78.5, "summer_efficiency_pct": 68.4, "comparative_hot_water_efficiency_pct": 49.9, "output_kw_max": 26.38, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001981", "000005", "0", "2012/Mar/27 10:12", "Potterton Myson", "Potterton Myson", "Kingfisher Mf RS 90", "", "HLW", "1997", "2001", "1", "1", "1", "1", "0", "", "", "1", "2", "2", "23.45", "26.38", "", "", "78.5", "68.4", "", "49.9", "", "2", "", "", "101", "1", "1", "80", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.8", "80.3", "", "", "", "", "80.2"]} +{"pcdb_id": 1983, "brand_name": "Powermax", "model_name": "140", "model_qualifier": "", "winter_efficiency_pct": 82.3, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 66.6, "output_kw_max": 14.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 3, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001983", "000099", "0", "2002/Aug/14 10:05", "Range Powermax", "Powermax", "140", "", "87AU97", "1999", "current", "1", "1", "1", "3", "0", "", "", "1", "2", "2", "14", "14", "", "", "82.3", "80.5", "", "66.6", "", "2", "", "", "107", "1", "1", "140", "0", "3", "", "0", "80", "0", "50", "5", "80", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.9", "82.0", "", "", "", "", "82.2"]} +{"pcdb_id": 1984, "brand_name": "Potterton Myson", "model_name": "Kingfisher Mf RS 80", "model_qualifier": "", "winter_efficiency_pct": 77.8, "summer_efficiency_pct": 67.7, "comparative_hot_water_efficiency_pct": 49.5, "output_kw_max": 23.45, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001984", "000005", "0", "2012/Mar/27 10:12", "Potterton Myson", "Potterton Myson", "Kingfisher Mf RS 80", "", "HLV", "1997", "2001", "1", "1", "1", "1", "0", "", "", "1", "2", "2", "20.52", "23.45", "", "", "77.8", "67.7", "", "49.5", "", "2", "", "", "101", "1", "1", "80", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.4", "79.5", "", "", "", "", "79.5"]} +{"pcdb_id": 1985, "brand_name": "Potterton Myson", "model_name": "Kingfisher Mf RS 70", "model_qualifier": "", "winter_efficiency_pct": 77.4, "summer_efficiency_pct": 67.3, "comparative_hot_water_efficiency_pct": 49.2, "output_kw_max": 20.52, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001985", "000005", "0", "2012/Mar/27 10:12", "Potterton Myson", "Potterton Myson", "Kingfisher Mf RS 70", "", "HLU", "1997", "2001", "1", "1", "1", "1", "0", "", "", "1", "2", "2", "17.58", "20.52", "", "", "77.4", "67.3", "", "49.2", "", "2", "", "", "101", "1", "1", "80", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "78.8", "79.2", "", "", "", "", "79.1"]} +{"pcdb_id": 1986, "brand_name": "Potterton Myson", "model_name": "Kingfisher Mf RS 60", "model_qualifier": "", "winter_efficiency_pct": 77.7, "summer_efficiency_pct": 67.6, "comparative_hot_water_efficiency_pct": 49.4, "output_kw_max": 17.58, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001986", "000005", "0", "2012/Mar/27 10:12", "Potterton Myson", "Potterton Myson", "Kingfisher Mf RS 60", "", "HLT", "1997", "2001", "1", "1", "1", "1", "0", "", "", "1", "2", "2", "14.65", "17.58", "", "", "77.7", "67.6", "", "49.4", "", "2", "", "", "101", "1", "1", "80", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.4", "79.3", "", "", "", "", "79.3"]} +{"pcdb_id": 1987, "brand_name": "Potterton Myson", "model_name": "Kingfisher Mf RS 50", "model_qualifier": "", "winter_efficiency_pct": 77.6, "summer_efficiency_pct": 67.5, "comparative_hot_water_efficiency_pct": 49.3, "output_kw_max": 14.65, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001987", "000005", "0", "2012/Mar/27 10:12", "Potterton Myson", "Potterton Myson", "Kingfisher Mf RS 50", "", "HLS", "1997", "2001", "1", "1", "1", "1", "0", "", "", "1", "2", "2", "11.72", "14.65", "", "", "77.6", "67.5", "", "49.3", "", "2", "", "", "101", "1", "1", "80", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "78.7", "79.6", "", "", "", "", "79.5"]} +{"pcdb_id": 1988, "brand_name": "Potterton Myson", "model_name": "Kingfisher Mf RS 40", "model_qualifier": "", "winter_efficiency_pct": 77.7, "summer_efficiency_pct": 67.6, "comparative_hot_water_efficiency_pct": 49.4, "output_kw_max": 11.72, "final_year_of_manufacture": 2002, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001988", "000005", "0", "2012/Mar/27 10:12", "Potterton Myson", "Potterton Myson", "Kingfisher Mf RS 40", "", "HLR", "1997", "2002", "1", "1", "1", "1", "0", "", "", "1", "2", "2", "8.8", "11.72", "", "", "77.7", "67.6", "", "49.4", "", "2", "", "", "101", "1", "1", "80", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.0", "79.6", "", "", "", "", "79.5"]} +{"pcdb_id": 1989, "brand_name": "Potterton Myson", "model_name": "Kingfisher Mf CF 100", "model_qualifier": "", "winter_efficiency_pct": 77.8, "summer_efficiency_pct": 67.7, "comparative_hot_water_efficiency_pct": 49.5, "output_kw_max": 29.31, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001989", "000005", "0", "2012/Mar/27 10:12", "Potterton Myson", "Potterton Myson", "Kingfisher Mf CF 100", "", "HME", "1997", "2001", "1", "1", "1", "1", "0", "", "", "1", "1", "2", "26.38", "29.31", "", "", "77.8", "67.7", "", "49.5", "", "2", "", "", "101", "1", "1", "80", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.2", "79.6", "", "", "", "", "79.6"]} +{"pcdb_id": 1990, "brand_name": "Potterton Myson", "model_name": "Kingfisher Mf CF 90", "model_qualifier": "", "winter_efficiency_pct": 78.5, "summer_efficiency_pct": 68.4, "comparative_hot_water_efficiency_pct": 49.9, "output_kw_max": 26.38, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001990", "000005", "0", "2012/Mar/27 10:12", "Potterton Myson", "Potterton Myson", "Kingfisher Mf CF 90", "", "HMD", "1997", "2001", "1", "1", "1", "1", "0", "", "", "1", "1", "2", "23.45", "26.38", "", "", "78.5", "68.4", "", "49.9", "", "2", "", "", "101", "1", "1", "80", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.8", "80.3", "", "", "", "", "80.2"]} +{"pcdb_id": 1991, "brand_name": "Potterton Myson", "model_name": "Kingfisher Mf CF 80", "model_qualifier": "", "winter_efficiency_pct": 77.8, "summer_efficiency_pct": 67.7, "comparative_hot_water_efficiency_pct": 49.5, "output_kw_max": 23.45, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001991", "000005", "0", "2012/Mar/27 10:12", "Potterton Myson", "Potterton Myson", "Kingfisher Mf CF 80", "", "HMC", "1997", "2001", "1", "1", "1", "1", "0", "", "", "1", "1", "2", "20.52", "23.45", "", "", "77.8", "67.7", "", "49.5", "", "2", "", "", "101", "1", "1", "80", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.4", "79.5", "", "", "", "", "79.5"]} +{"pcdb_id": 1992, "brand_name": "Potterton Myson", "model_name": "Kingfisher Mf CF 70", "model_qualifier": "", "winter_efficiency_pct": 77.4, "summer_efficiency_pct": 67.3, "comparative_hot_water_efficiency_pct": 49.2, "output_kw_max": 20.52, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001992", "000005", "0", "2012/Mar/27 10:12", "Potterton Myson", "Potterton Myson", "Kingfisher Mf CF 70", "", "HMB", "1997", "2001", "1", "1", "1", "1", "0", "", "", "1", "1", "2", "17.58", "20.52", "", "", "77.4", "67.3", "", "49.2", "", "2", "", "", "101", "1", "1", "80", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "78.8", "79.2", "", "", "", "", "79.1"]} +{"pcdb_id": 1993, "brand_name": "Potterton Myson", "model_name": "Kingfisher Mf CF 60", "model_qualifier": "", "winter_efficiency_pct": 77.7, "summer_efficiency_pct": 67.6, "comparative_hot_water_efficiency_pct": 49.4, "output_kw_max": 17.58, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001993", "000005", "0", "2012/Mar/27 10:12", "Potterton Myson", "Potterton Myson", "Kingfisher Mf CF 60", "", "HMA", "1997", "2001", "1", "1", "1", "1", "0", "", "", "1", "1", "2", "14.65", "17.58", "", "", "77.7", "67.6", "", "49.4", "", "2", "", "", "101", "1", "1", "80", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.4", "79.3", "", "", "", "", "79.3"]} +{"pcdb_id": 1994, "brand_name": "Potterton Myson", "model_name": "Kingfisher Mf CF 50", "model_qualifier": "", "winter_efficiency_pct": 77.6, "summer_efficiency_pct": 67.5, "comparative_hot_water_efficiency_pct": 49.3, "output_kw_max": 14.65, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001994", "000005", "0", "2012/Mar/27 10:12", "Potterton Myson", "Potterton Myson", "Kingfisher Mf CF 50", "", "HLZ", "1997", "2001", "1", "1", "1", "1", "0", "", "", "1", "1", "2", "11.72", "14.65", "", "", "77.6", "67.5", "", "49.3", "", "2", "", "", "101", "1", "1", "80", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "78.7", "79.6", "", "", "", "", "79.5"]} +{"pcdb_id": 1995, "brand_name": "Potterton Myson", "model_name": "Kingfisher Mf CF 40", "model_qualifier": "", "winter_efficiency_pct": 77.7, "summer_efficiency_pct": 67.6, "comparative_hot_water_efficiency_pct": 49.4, "output_kw_max": 11.72, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001995", "000005", "0", "2012/Mar/27 10:12", "Potterton Myson", "Potterton Myson", "Kingfisher Mf CF 40", "", "HLY", "1997", "2001", "1", "1", "1", "1", "0", "", "", "1", "1", "2", "8.8", "11.72", "", "", "77.7", "67.6", "", "49.4", "", "2", "", "", "101", "1", "1", "80", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.0", "79.6", "", "", "", "", "79.5"]} +{"pcdb_id": 1996, "brand_name": "Potterton Myson", "model_name": "Housewarmer 45", "model_qualifier": "", "winter_efficiency_pct": 78.3, "summer_efficiency_pct": 68.2, "comparative_hot_water_efficiency_pct": 49.8, "output_kw_max": 13.2, "final_year_of_manufacture": 2000, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001996", "000005", "0", "2012/Mar/27 10:12", "Potterton Myson", "Potterton Myson", "Housewarmer 45", "", "HGK", "1994", "2000", "1", "4", "1", "1", "0", "", "", "1", "1", "1", "13.2", "13.2", "", "", "78.3", "68.2", "", "49.8", "", "2", "", "", "101", "1", "1", "5", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "77.9", "81.8", "", "", "", "", "81.1"]} +{"pcdb_id": 1997, "brand_name": "Potterton Myson", "model_name": "Housewarmer 55", "model_qualifier": "", "winter_efficiency_pct": 80.2, "summer_efficiency_pct": 70.1, "comparative_hot_water_efficiency_pct": 51.2, "output_kw_max": 16.1, "final_year_of_manufacture": 2000, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["001997", "000005", "0", "2012/Mar/27 10:12", "Potterton Myson", "Potterton Myson", "Housewarmer 55", "", "HGL", "1994", "2000", "1", "4", "1", "1", "0", "", "", "1", "1", "1", "16.1", "16.1", "", "", "80.2", "70.1", "", "51.2", "", "2", "", "", "101", "1", "1", "5", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.7", "83.9", "", "", "", "", "83.1"]} +{"pcdb_id": 2004, "brand_name": "Potterton Myson", "model_name": "Scottish Gas 30F2", "model_qualifier": "", "winter_efficiency_pct": 76.1, "summer_efficiency_pct": 66.0, "comparative_hot_water_efficiency_pct": 48.2, "output_kw_max": 8.79, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["002004", "000005", "0", "2012/Mar/27 10:12", "Potterton Myson", "Potterton Myson", "Scottish Gas 30F2", "", "LSB", "1999", "2001", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "5.86", "8.79", "", "", "76.1", "66.0", "", "48.2", "", "2", "", "", "101", "1", "1", "80", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "78.6", "76.8", "", "", "", "", "77.1"]} +{"pcdb_id": 2005, "brand_name": "Potterton Myson", "model_name": "Scottish Gas 40F2", "model_qualifier": "", "winter_efficiency_pct": 77.2, "summer_efficiency_pct": 67.1, "comparative_hot_water_efficiency_pct": 49.0, "output_kw_max": 11.72, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["002005", "000005", "0", "2012/Mar/27 10:12", "Potterton Myson", "Potterton Myson", "Scottish Gas 40F2", "", "LSC", "1999", "2001", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "8.79", "11.72", "", "", "77.2", "67.1", "", "49.0", "", "2", "", "", "101", "1", "1", "80", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.6", "78.0", "", "", "", "", "78.3"]} +{"pcdb_id": 2006, "brand_name": "Potterton Myson", "model_name": "Scottish Gas 50F2", "model_qualifier": "", "winter_efficiency_pct": 77.6, "summer_efficiency_pct": 67.5, "comparative_hot_water_efficiency_pct": 49.3, "output_kw_max": 14.65, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["002006", "000005", "0", "2012/Mar/27 10:12", "Potterton Myson", "Potterton Myson", "Scottish Gas 50F2", "", "LSD", "1999", "2001", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "11.72", "14.65", "", "", "77.6", "67.5", "", "49.3", "", "2", "", "", "101", "1", "1", "80", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "80.2", "78.3", "", "", "", "", "78.7"]} +{"pcdb_id": 2021, "brand_name": "Potterton Myson", "model_name": "Suprima 120", "model_qualifier": "", "winter_efficiency_pct": 78.7, "summer_efficiency_pct": 68.6, "comparative_hot_water_efficiency_pct": 50.1, "output_kw_max": 35.17, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["002021", "000005", "0", "2012/Mar/27 10:12", "Potterton Myson", "Potterton Myson", "Suprima 120", "", "HMT", "1999", "2001", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "23.45", "35.17", "", "", "78.7", "68.6", "", "50.1", "", "2", "", "", "101", "1", "1", "80", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "80.2", "80.4", "", "", "", "", "80.3"]} +{"pcdb_id": 2022, "brand_name": "Potterton Myson", "model_name": "Scottish Gas 80F2", "model_qualifier": "", "winter_efficiency_pct": 76.8, "summer_efficiency_pct": 66.7, "comparative_hot_water_efficiency_pct": 48.7, "output_kw_max": 23.45, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["002022", "000005", "0", "2012/Mar/27 10:12", "Potterton Myson", "Potterton Myson", "Scottish Gas 80F2", "", "LSF", "1999", "2001", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "17.58", "23.45", "", "", "76.8", "66.7", "", "48.7", "", "2", "", "", "101", "1", "1", "80", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.2", "77.6", "", "", "", "", "77.9"]} +{"pcdb_id": 2027, "brand_name": "Potterton Myson", "model_name": "Scottish Gas 60F2", "model_qualifier": "", "winter_efficiency_pct": 77.6, "summer_efficiency_pct": 67.5, "comparative_hot_water_efficiency_pct": 49.3, "output_kw_max": 17.58, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["002027", "000005", "0", "2012/Mar/27 10:12", "Potterton Myson", "Potterton Myson", "Scottish Gas 60F2", "", "LSE", "1999", "2001", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "14.65", "17.58", "", "", "77.6", "67.5", "", "49.3", "", "2", "", "", "101", "1", "1", "80", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "80.0", "78.4", "", "", "", "", "78.7"]} +{"pcdb_id": 2028, "brand_name": "Potterton Myson", "model_name": "Statesman Kitchen 90/110", "model_qualifier": "Kerosene", "winter_efficiency_pct": 83.0, "summer_efficiency_pct": 71.3, "comparative_hot_water_efficiency_pct": 52.1, "output_kw_max": 32.0, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["002028", "000005", "0", "2012/Mar/27 10:12", "Potterton Myson", "Potterton Myson", "Statesman Kitchen 90/110", "Kerosene", "LPX", "1998", "2001", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "26.0", "32.0", "", "", "83.0", "71.3", "", "52.1", "", "2", "", "", "201", "1", "1", "200", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "83.6", "82.5", "", "", "", "", "82.7"]} +{"pcdb_id": 2029, "brand_name": "Potterton Myson", "model_name": "Statesman Kitchen 90/110", "model_qualifier": "Gas oil", "winter_efficiency_pct": 83.0, "summer_efficiency_pct": 71.3, "comparative_hot_water_efficiency_pct": 52.1, "output_kw_max": 32.0, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["002029", "000005", "0", "2012/Mar/27 10:12", "Potterton Myson", "Potterton Myson", "Statesman Kitchen 90/110", "Gas oil", "LPT", "1998", "2001", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "26.0", "32.0", "", "", "83.0", "71.3", "", "52.1", "", "2", "", "", "201", "1", "1", "200", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "83.6", "82.5", "", "", "", "", "82.7"]} +{"pcdb_id": 2030, "brand_name": "Potterton Myson", "model_name": "Statesman Utility 50/70", "model_qualifier": "Kerosene", "winter_efficiency_pct": 82.5, "summer_efficiency_pct": 70.8, "comparative_hot_water_efficiency_pct": 51.7, "output_kw_max": 20.0, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["002030", "000005", "0", "2012/Mar/27 10:12", "Potterton Myson", "Potterton Myson", "Statesman Utility 50/70", "Kerosene", "LRH", "1998", "2001", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "15.0", "20.0", "", "", "82.5", "70.8", "", "51.7", "", "2", "", "", "201", "1", "1", "200", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.6", "83.3", "", "", "", "", "83.0"]} +{"pcdb_id": 2031, "brand_name": "Potterton Myson", "model_name": "Statesman Kitchen 45/50", "model_qualifier": "Kerosene", "winter_efficiency_pct": 86.2, "summer_efficiency_pct": 74.5, "comparative_hot_water_efficiency_pct": 54.4, "output_kw_max": 15.0, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["002031", "000005", "0", "2012/Mar/27 10:12", "Potterton Myson", "Potterton Myson", "Statesman Kitchen 45/50", "Kerosene", "LRB", "1998", "2001", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "13.0", "15.0", "", "", "86.2", "74.5", "", "54.4", "", "2", "", "", "201", "1", "1", "200", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.3", "86.1", "", "", "", "", "86.3"]} +{"pcdb_id": 2032, "brand_name": "Potterton Myson", "model_name": "Statesman Utility 50/70", "model_qualifier": "Gas oil", "winter_efficiency_pct": 82.5, "summer_efficiency_pct": 70.8, "comparative_hot_water_efficiency_pct": 51.7, "output_kw_max": 20.0, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["002032", "000005", "0", "2012/Mar/27 10:12", "Potterton Myson", "Potterton Myson", "Statesman Utility 50/70", "Gas oil", "LRE", "1998", "2001", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "15.0", "20.0", "", "", "82.5", "70.8", "", "51.7", "", "2", "", "", "201", "1", "1", "200", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.6", "83.3", "", "", "", "", "83.0"]} +{"pcdb_id": 2033, "brand_name": "Potterton Myson", "model_name": "Statesman Utility 70/90", "model_qualifier": "Gas oil", "winter_efficiency_pct": 85.9, "summer_efficiency_pct": 74.2, "comparative_hot_water_efficiency_pct": 54.2, "output_kw_max": 26.0, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["002033", "000005", "0", "2012/Mar/27 10:12", "Potterton Myson", "Potterton Myson", "Statesman Utility 70/90", "Gas oil", "LRD", "1998", "2001", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "20.0", "26.0", "", "", "85.9", "74.2", "", "54.2", "", "2", "", "", "201", "1", "1", "200", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.3", "85.5", "", "", "", "", "85.9"]} +{"pcdb_id": 2034, "brand_name": "Potterton Myson", "model_name": "Statesman Utility 70/90", "model_qualifier": "Kerosene", "winter_efficiency_pct": 85.9, "summer_efficiency_pct": 74.2, "comparative_hot_water_efficiency_pct": 54.2, "output_kw_max": 26.0, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["002034", "000005", "0", "2012/Mar/27 10:12", "Potterton Myson", "Potterton Myson", "Statesman Utility 70/90", "Kerosene", "LRG", "1998", "2001", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "20.0", "26.0", "", "", "85.9", "74.2", "", "54.2", "", "2", "", "", "201", "1", "1", "200", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.3", "85.5", "", "", "", "", "85.9"]} +{"pcdb_id": 2035, "brand_name": "Potterton Myson", "model_name": "Statesman Flowsure plus", "model_qualifier": "", "winter_efficiency_pct": 79.2, "summer_efficiency_pct": 71.1, "comparative_hot_water_efficiency_pct": 31.9, "output_kw_max": 25.0, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 1, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["002035", "000005", "0", "2024/Jan/31 10:17", "Potterton Myson", "Potterton Myson", "Statesman Flowsure plus", "", "LNC", "1996", "2001", "4", "1", "1", "2", "0", "", "", "1", "1", "2", "19", "25.0", "", "", "79.2", "71.1", "", "31.9", "", "2", "", "", "203", "1", "1", "200", "0", "1", "1", "0", "40", "0", "13", "4", "73", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.0", "80.2", "", "", "", "", "80.5"]} +{"pcdb_id": 2036, "brand_name": "Potterton Myson", "model_name": "Statesman Flowsure", "model_qualifier": "", "winter_efficiency_pct": 79.3, "summer_efficiency_pct": 69.8, "comparative_hot_water_efficiency_pct": 49.1, "output_kw_max": 25.0, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["002036", "000005", "0", "2005/Nov/15 11:32", "Potterton Myson", "Potterton Myson", "Statesman Flowsure", "", "LNB", "1996", "2001", "4", "1", "1", "2", "0", "", "", "1", "1", "2", "19.0", "25.0", "", "", "79.3", "69.8", "", "49.1", "", "2", "", "", "202", "1", "1", "200", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.0", "80.2", "", "", "", "", "80.5"]} +{"pcdb_id": 2037, "brand_name": "Potterton Myson", "model_name": "Statesman System 65/85", "model_qualifier": "", "winter_efficiency_pct": 81.1, "summer_efficiency_pct": 69.4, "comparative_hot_water_efficiency_pct": 50.7, "output_kw_max": 25.0, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["002037", "000005", "0", "2012/Mar/27 10:12", "Potterton Myson", "Potterton Myson", "Statesman System 65/85", "", "LNA", "1996", "2001", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "19.0", "25.0", "", "", "81.1", "69.4", "", "50.7", "", "2", "", "", "201", "1", "1", "200", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.0", "80.2", "", "", "", "", "80.5"]} +{"pcdb_id": 2038, "brand_name": "Potterton Myson", "model_name": "Suprima 30", "model_qualifier": "", "winter_efficiency_pct": 77.5, "summer_efficiency_pct": 67.4, "comparative_hot_water_efficiency_pct": 49.2, "output_kw_max": 8.8, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["002038", "000005", "0", "2012/Mar/27 10:12", "Potterton Myson", "Potterton Myson", "Suprima 30", "", "HHN", "1997", "2001", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "5.5", "8.8", "", "", "77.5", "67.4", "", "49.2", "", "2", "", "", "101", "1", "1", "80", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.6", "78.6", "", "", "", "", "78.8"]} +{"pcdb_id": 2039, "brand_name": "Potterton Myson", "model_name": "Suprima 40", "model_qualifier": "", "winter_efficiency_pct": 77.7, "summer_efficiency_pct": 67.6, "comparative_hot_water_efficiency_pct": 49.4, "output_kw_max": 11.7, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["002039", "000005", "0", "2012/Mar/27 10:12", "Potterton Myson", "Potterton Myson", "Suprima 40", "", "HHO", "1997", "2001", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "8.5", "11.7", "", "", "77.7", "67.6", "", "49.4", "", "2", "", "", "101", "1", "1", "80", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "80.1", "78.6", "", "", "", "", "78.9"]} +{"pcdb_id": 2040, "brand_name": "Potterton Myson", "model_name": "Suprima 50", "model_qualifier": "", "winter_efficiency_pct": 78.4, "summer_efficiency_pct": 68.3, "comparative_hot_water_efficiency_pct": 49.9, "output_kw_max": 14.7, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["002040", "000005", "0", "2012/Mar/27 10:12", "Potterton Myson", "Potterton Myson", "Suprima 50", "", "HHP", "1997", "2001", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "11.4", "14.7", "", "", "78.4", "68.3", "", "49.9", "", "2", "", "", "101", "1", "1", "80", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "80.5", "79.5", "", "", "", "", "79.7"]} +{"pcdb_id": 2041, "brand_name": "Potterton Myson", "model_name": "Suprima 60", "model_qualifier": "", "winter_efficiency_pct": 78.8, "summer_efficiency_pct": 68.7, "comparative_hot_water_efficiency_pct": 50.2, "output_kw_max": 17.6, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["002041", "000005", "0", "2012/Mar/27 10:12", "Potterton Myson", "Potterton Myson", "Suprima 60", "", "HHR", "1997", "2001", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "14.4", "17.6", "", "", "78.8", "68.7", "", "50.2", "", "2", "", "", "101", "1", "1", "80", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "80.9", "79.8", "", "", "", "", "80.0"]} +{"pcdb_id": 2042, "brand_name": "Potterton Myson", "model_name": "Suprima 70", "model_qualifier": "", "winter_efficiency_pct": 79.3, "summer_efficiency_pct": 69.2, "comparative_hot_water_efficiency_pct": 50.6, "output_kw_max": 20.5, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["002042", "000005", "0", "2012/Mar/27 10:12", "Potterton Myson", "Potterton Myson", "Suprima 70", "", "HHS", "1997", "2001", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "17.3", "20.5", "", "", "79.3", "69.2", "", "50.6", "", "2", "", "", "101", "1", "1", "80", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.3", "80.5", "", "", "", "", "80.7"]} +{"pcdb_id": 2043, "brand_name": "Potterton Myson", "model_name": "Suprima 80", "model_qualifier": "", "winter_efficiency_pct": 78.1, "summer_efficiency_pct": 68.0, "comparative_hot_water_efficiency_pct": 49.7, "output_kw_max": 23.4, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["002043", "000005", "0", "2012/Mar/27 10:12", "Potterton Myson", "Potterton Myson", "Suprima 80", "", "HHT", "1997", "2001", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "20.1", "23.4", "", "", "78.1", "68.0", "", "49.7", "", "2", "", "", "101", "1", "1", "80", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "80.4", "79.1", "", "", "", "", "79.3"]} +{"pcdb_id": 2044, "brand_name": "Potterton Myson", "model_name": "Suprima 100", "model_qualifier": "", "winter_efficiency_pct": 79.2, "summer_efficiency_pct": 69.1, "comparative_hot_water_efficiency_pct": 50.5, "output_kw_max": 28.72, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["002044", "000005", "0", "2012/Mar/27 10:12", "Potterton Myson", "Potterton Myson", "Suprima 100", "", "HHV", "1997", "2001", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "28.72", "28.72", "", "", "79.2", "69.1", "", "50.5", "", "2", "", "", "101", "1", "1", "80", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.1", "80.5", "", "", "", "", "80.7"]} +{"pcdb_id": 2045, "brand_name": "Potterton Myson", "model_name": "Puma Flowsure plus", "model_qualifier": "", "winter_efficiency_pct": 80.4, "summer_efficiency_pct": 71.3, "comparative_hot_water_efficiency_pct": 41.3, "output_kw_max": 24.0, "final_year_of_manufacture": 2000, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["002045", "000005", "0", "2024/Jan/31 10:17", "Potterton Myson", "Potterton Myson", "Puma Flowsure plus", "", "LKX + LLN", "1996", "2000", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "24.0", "24.0", "", "", "80.4", "71.3", "", "41.3", "", "2", "", "", "106", "1", "2", "90", "0", "2", "1", "0", "44.7", "0", "20", "5", "73", "37", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.3", "81.3", "", "", "", "", "81.3"]} +{"pcdb_id": 2046, "brand_name": "Potterton Myson", "model_name": "Puma 80e Security", "model_qualifier": "", "winter_efficiency_pct": 80.1, "summer_efficiency_pct": 70.0, "comparative_hot_water_efficiency_pct": 49.2, "output_kw_max": 24.0, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["002046", "000005", "0", "2006/Jan/17 12:55", "Potterton Myson", "Potterton Myson", "Puma 80e Security", "", "LSG", "1999", "2001", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "24.0", "24.0", "", "", "80.1", "70.0", "", "49.2", "", "2", "", "", "104", "1", "2", "90", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.3", "81.3", "", "", "", "", "81.3"]} +{"pcdb_id": 2047, "brand_name": "Potterton Myson", "model_name": "Puma 80e", "model_qualifier": "", "winter_efficiency_pct": 80.1, "summer_efficiency_pct": 70.0, "comparative_hot_water_efficiency_pct": 49.2, "output_kw_max": 24.0, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["002047", "000005", "0", "2006/Jan/17 12:55", "Potterton Myson", "Potterton Myson", "Puma 80e", "", "LGD", "1993", "2001", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "24.0", "24.0", "", "", "80.1", "70.0", "", "49.2", "", "2", "", "", "104", "1", "2", "90", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.3", "81.3", "", "", "", "", "81.3"]} +{"pcdb_id": 2048, "brand_name": "Potterton Myson", "model_name": "Puma 80 Security", "model_qualifier": "", "winter_efficiency_pct": 76.1, "summer_efficiency_pct": 66.0, "comparative_hot_water_efficiency_pct": 46.4, "output_kw_max": 24.0, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["002048", "000005", "0", "2006/Jan/17 12:55", "Potterton Myson", "Potterton Myson", "Puma 80 Security", "", "LSH", "1999", "2001", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "24.0", "24.0", "", "", "76.1", "66.0", "", "46.4", "", "2", "", "", "104", "2", "2", "90", "20", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.3", "81.3", "", "", "", "", "81.3"]} +{"pcdb_id": 2049, "brand_name": "Potterton Myson", "model_name": "Puma 80", "model_qualifier": "", "winter_efficiency_pct": 76.1, "summer_efficiency_pct": 66.0, "comparative_hot_water_efficiency_pct": 46.4, "output_kw_max": 24.0, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["002049", "000005", "0", "2006/Jan/17 12:55", "Potterton Myson", "Potterton Myson", "Puma 80", "", "LGC", "1993", "2001", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "24.0", "24.0", "", "", "76.1", "66.0", "", "46.4", "", "2", "", "", "104", "2", "2", "90", "20", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.3", "81.3", "", "", "", "", "81.3"]} +{"pcdb_id": 2050, "brand_name": "Potterton Myson", "model_name": "Puma 100 Security", "model_qualifier": "", "winter_efficiency_pct": 75.7, "summer_efficiency_pct": 65.6, "comparative_hot_water_efficiency_pct": 46.1, "output_kw_max": 29.0, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["002050", "000005", "0", "2006/Jan/17 12:55", "Potterton Myson", "Potterton Myson", "Puma 100 Security", "", "LSK", "1999", "2001", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "29.0", "29.0", "", "", "75.7", "65.6", "", "46.1", "", "2", "", "", "104", "2", "2", "90", "20", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.2", "80.5", "", "", "", "", "80.7"]} +{"pcdb_id": 2051, "brand_name": "Potterton Myson", "model_name": "Puma 100e Security", "model_qualifier": "", "winter_efficiency_pct": 79.7, "summer_efficiency_pct": 69.6, "comparative_hot_water_efficiency_pct": 48.9, "output_kw_max": 29.0, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["002051", "000005", "0", "2006/Jan/17 12:55", "Potterton Myson", "Potterton Myson", "Puma 100e Security", "", "LSJ", "1999", "2001", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "29.0", "29.0", "", "", "79.7", "69.6", "", "48.9", "", "2", "", "", "104", "1", "2", "90", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.2", "80.5", "", "", "", "", "80.7"]} +{"pcdb_id": 2052, "brand_name": "Potterton Myson", "model_name": "Puma 100ec", "model_qualifier": "", "winter_efficiency_pct": 79.7, "summer_efficiency_pct": 69.6, "comparative_hot_water_efficiency_pct": 48.9, "output_kw_max": 29.0, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["002052", "000005", "0", "2006/Jan/17 12:55", "Potterton Myson", "Potterton Myson", "Puma 100ec", "", "LRS", "1999", "2001", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "29.0", "29.0", "", "", "79.7", "69.6", "", "48.9", "", "2", "", "", "104", "1", "2", "90", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.2", "80.5", "", "", "", "", "80.7"]} +{"pcdb_id": 2053, "brand_name": "Potterton Myson", "model_name": "Puma 100e", "model_qualifier": "", "winter_efficiency_pct": 79.7, "summer_efficiency_pct": 69.6, "comparative_hot_water_efficiency_pct": 48.9, "output_kw_max": 29.0, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["002053", "000005", "0", "2006/Jan/17 12:55", "Potterton Myson", "Potterton Myson", "Puma 100e", "", "LGF", "1993", "2001", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "29.0", "29.0", "", "", "79.7", "69.6", "", "48.9", "", "2", "", "", "104", "1", "2", "90", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.2", "80.5", "", "", "", "", "80.7"]} +{"pcdb_id": 2054, "brand_name": "Potterton Myson", "model_name": "Puma 100", "model_qualifier": "", "winter_efficiency_pct": 75.7, "summer_efficiency_pct": 65.6, "comparative_hot_water_efficiency_pct": 46.1, "output_kw_max": 29.0, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["002054", "000005", "0", "2006/Jan/17 12:55", "Potterton Myson", "Potterton Myson", "Puma 100", "", "LGE", "1993", "2001", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "29.0", "29.0", "", "", "75.7", "65.6", "", "46.1", "", "2", "", "", "104", "2", "2", "90", "20", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.2", "80.5", "", "", "", "", "80.7"]} +{"pcdb_id": 2055, "brand_name": "Potterton Myson", "model_name": "Combi 80", "model_qualifier": "", "winter_efficiency_pct": 80.1, "summer_efficiency_pct": 70.0, "comparative_hot_water_efficiency_pct": 49.2, "output_kw_max": 24.0, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["002055", "000005", "0", "2006/Jan/17 12:55", "Potterton Myson", "Potterton Myson", "Combi 80", "", "LRK", "1998", "2001", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "24.0", "24.0", "", "", "80.1", "70.0", "", "49.2", "", "2", "", "", "104", "1", "2", "200", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.3", "81.3", "", "", "", "", "81.3"]} +{"pcdb_id": 2056, "brand_name": "Potterton Myson", "model_name": "Statesman Kitchen 50/70", "model_qualifier": "Gas oil", "winter_efficiency_pct": 82.5, "summer_efficiency_pct": 70.8, "comparative_hot_water_efficiency_pct": 51.7, "output_kw_max": 20.0, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["002056", "000005", "0", "2012/Mar/27 10:12", "Potterton Myson", "Potterton Myson", "Statesman Kitchen 50/70", "Gas oil", "LPW", "1998", "2001", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "15.0", "20.0", "", "", "82.5", "70.8", "", "51.7", "", "2", "", "", "201", "1", "1", "200", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.6", "83.3", "", "", "", "", "83.0"]} +{"pcdb_id": 2057, "brand_name": "Potterton Myson", "model_name": "Statesman Kitchen 50/70", "model_qualifier": "Kerosene", "winter_efficiency_pct": 82.5, "summer_efficiency_pct": 70.8, "comparative_hot_water_efficiency_pct": 51.7, "output_kw_max": 20.0, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["002057", "000005", "0", "2012/Mar/27 10:12", "Potterton Myson", "Potterton Myson", "Statesman Kitchen 50/70", "Kerosene", "LRA", "1998", "2001", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "15.0", "20.0", "", "", "82.5", "70.8", "", "51.7", "", "2", "", "", "201", "1", "1", "200", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.6", "83.3", "", "", "", "", "83.0"]} +{"pcdb_id": 2058, "brand_name": "Potterton Myson", "model_name": "Statesman Kitchen 70/90", "model_qualifier": "Gas oil", "winter_efficiency_pct": 85.9, "summer_efficiency_pct": 74.2, "comparative_hot_water_efficiency_pct": 54.2, "output_kw_max": 26.0, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["002058", "000005", "0", "2012/Mar/27 10:12", "Potterton Myson", "Potterton Myson", "Statesman Kitchen 70/90", "Gas oil", "LPV", "1998", "2001", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "20.0", "26.0", "", "", "85.9", "74.2", "", "54.2", "", "2", "", "", "201", "1", "1", "200", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.3", "85.5", "", "", "", "", "85.9"]} +{"pcdb_id": 2059, "brand_name": "Potterton Myson", "model_name": "Statesman Utility 90/110", "model_qualifier": "Gas oil", "winter_efficiency_pct": 83.0, "summer_efficiency_pct": 71.3, "comparative_hot_water_efficiency_pct": 52.1, "output_kw_max": 32.0, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["002059", "000005", "0", "2012/Mar/27 10:12", "Potterton Myson", "Potterton Myson", "Statesman Utility 90/110", "Gas oil", "LRC", "1998", "2001", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "26.0", "32.0", "", "", "83.0", "71.3", "", "52.1", "", "2", "", "", "201", "1", "1", "200", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "83.6", "82.5", "", "", "", "", "82.7"]} +{"pcdb_id": 2060, "brand_name": "Potterton Myson", "model_name": "Statesman Kitchen 70/90", "model_qualifier": "Kerosene", "winter_efficiency_pct": 85.9, "summer_efficiency_pct": 74.2, "comparative_hot_water_efficiency_pct": 54.2, "output_kw_max": 26.0, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["002060", "000005", "0", "2012/Mar/27 10:12", "Potterton Myson", "Potterton Myson", "Statesman Kitchen 70/90", "Kerosene", "LPY", "1998", "2001", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "20.0", "26.0", "", "", "85.9", "74.2", "", "54.2", "", "2", "", "", "201", "1", "1", "200", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.3", "85.5", "", "", "", "", "85.9"]} +{"pcdb_id": 2061, "brand_name": "Potterton Myson", "model_name": "Statesman Utility 90/110", "model_qualifier": "Kerosene", "winter_efficiency_pct": 83.0, "summer_efficiency_pct": 71.3, "comparative_hot_water_efficiency_pct": 52.1, "output_kw_max": 32.0, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["002061", "000005", "0", "2012/Mar/27 10:12", "Potterton Myson", "Potterton Myson", "Statesman Utility 90/110", "Kerosene", "LRF", "1998", "2001", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "26.0", "32.0", "", "", "83.0", "71.3", "", "52.1", "", "2", "", "", "201", "1", "1", "200", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "83.6", "82.5", "", "", "", "", "82.7"]} +{"pcdb_id": 2062, "brand_name": "Potterton Myson", "model_name": "Envoy 30 System", "model_qualifier": "", "winter_efficiency_pct": 85.6, "summer_efficiency_pct": 78.0, "comparative_hot_water_efficiency_pct": 57.0, "output_kw_max": 9.7, "final_year_of_manufacture": 2000, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["002062", "000005", "0", "2012/Mar/27 10:12", "Potterton Myson", "Potterton Myson", "Envoy 30 System", "", "HKK", "1995", "2000", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "9.7", "9.7", "", "", "85.6", "78.0", "", "57.0", "", "2", "", "", "101", "1", "1", "80", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "87.5", "94.5", "", "", "", "", "93.2"]} +{"pcdb_id": 2063, "brand_name": "Potterton Myson", "model_name": "Envoy 40 System", "model_qualifier": "", "winter_efficiency_pct": 85.5, "summer_efficiency_pct": 77.9, "comparative_hot_water_efficiency_pct": 56.9, "output_kw_max": 12.8, "final_year_of_manufacture": 2000, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["002063", "000005", "0", "2012/Mar/27 10:12", "Potterton Myson", "Potterton Myson", "Envoy 40 System", "", "HKL", "1995", "2000", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "12.8", "12.8", "", "", "85.5", "77.9", "", "56.9", "", "2", "", "", "101", "1", "1", "80", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "87.8", "94.0", "", "", "", "", "92.8"]} +{"pcdb_id": 2064, "brand_name": "Potterton Myson", "model_name": "Envoy 50 System", "model_qualifier": "", "winter_efficiency_pct": 85.5, "summer_efficiency_pct": 77.9, "comparative_hot_water_efficiency_pct": 56.9, "output_kw_max": 16.1, "final_year_of_manufacture": 2000, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["002064", "000005", "0", "2012/Mar/27 10:12", "Potterton Myson", "Potterton Myson", "Envoy 50 System", "", "HKM", "1995", "2000", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "16.1", "16.1", "", "", "85.5", "77.9", "", "56.9", "", "2", "", "", "101", "1", "1", "80", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "88.0", "94.0", "", "", "", "", "92.8"]} +{"pcdb_id": 2065, "brand_name": "Potterton Myson", "model_name": "Envoy 60 System", "model_qualifier": "", "winter_efficiency_pct": 85.2, "summer_efficiency_pct": 77.6, "comparative_hot_water_efficiency_pct": 56.7, "output_kw_max": 19.0, "final_year_of_manufacture": 2000, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["002065", "000005", "0", "2012/Mar/27 10:12", "Potterton Myson", "Potterton Myson", "Envoy 60 System", "", "HKN", "1995", "2000", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "19.0", "19.0", "", "", "85.2", "77.6", "", "56.7", "", "2", "", "", "101", "1", "1", "80", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "86.8", "93.8", "", "", "", "", "92.5"]} +{"pcdb_id": 2066, "brand_name": "Potterton Myson", "model_name": "Envoy 80 System", "model_qualifier": "", "winter_efficiency_pct": 85.1, "summer_efficiency_pct": 77.5, "comparative_hot_water_efficiency_pct": 56.6, "output_kw_max": 25.0, "final_year_of_manufacture": 2000, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["002066", "000005", "0", "2012/Mar/27 10:12", "Potterton Myson", "Potterton Myson", "Envoy 80 System", "", "HKP", "1995", "2000", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "25", "25.0", "", "", "85.1", "77.5", "", "56.6", "", "2", "", "", "101", "1", "1", "80", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "87.4", "93.3", "", "", "", "", "92.2"]} +{"pcdb_id": 2067, "brand_name": "Potterton Myson", "model_name": "Envoy 80 Flowsure", "model_qualifier": "", "winter_efficiency_pct": 86.5, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 49.0, "output_kw_max": 25.0, "final_year_of_manufacture": 2000, "subsidiary_type": 0, "store_type": 1, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["002067", "000005", "0", "2024/Jan/31 10:17", "Potterton Myson", "Potterton Myson", "Envoy 80 Flowsure", "", "HKW", "1996", "2000", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "25.0", "25.0", "", "", "86.5", "79.2", "", "49.0", "", "2", "", "", "106", "1", "2", "80", "0", "1", "1", "0", "18.7", "0", "35", "2", "75", "20", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.4", "93.3", "", "", "", "", "92.2"]} +{"pcdb_id": 2068, "brand_name": "Potterton Myson", "model_name": "Envoy 80 Flowsure plus", "model_qualifier": "", "winter_efficiency_pct": 86.5, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 45.9, "output_kw_max": 25.0, "final_year_of_manufacture": 2000, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["002068", "000005", "0", "2024/Jan/31 10:17", "Potterton Myson", "Potterton Myson", "Envoy 80 Flowsure plus", "", "HKW", "1996", "2000", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "25.0", "25.0", "", "", "86.5", "79.2", "", "45.9", "", "2", "", "", "106", "1", "2", "80", "0", "2", "1", "0", "44.7", "0", "20", "5", "73", "37", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.4", "93.3", "", "", "", "", "92.2"]} +{"pcdb_id": 3971, "brand_name": "Keston", "model_name": "Thermomatic", "model_qualifier": "RSM20FB", "winter_efficiency_pct": 78.9, "summer_efficiency_pct": 69.6, "comparative_hot_water_efficiency_pct": 48.9, "output_kw_max": 23.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["003971", "000022", "0", "2001/Nov/30 13:26", "Thermomatic Srl", "Keston", "Thermomatic", "RSM20FB", "", "1988", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "23", "23", "", "", "78.9", "69.6", "", "48.9", "", "2", "", "", "103", "1", "1", "180", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.5", "80.3", "", "", "", "", "80.5"]} +{"pcdb_id": 3972, "brand_name": "Keston", "model_name": "Thermomatic", "model_qualifier": "RSM25FB", "winter_efficiency_pct": 78.8, "summer_efficiency_pct": 69.5, "comparative_hot_water_efficiency_pct": 48.9, "output_kw_max": 28.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["003972", "000022", "0", "2001/Nov/30 13:26", "Thermomatic Srl", "Keston", "Thermomatic", "RSM25FB", "", "1988", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "28", "28", "", "", "78.8", "69.5", "", "48.9", "", "2", "", "", "103", "1", "1", "180", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.4", "80.3", "", "", "", "", "80.5"]} +{"pcdb_id": 3975, "brand_name": "Glow-worm", "model_name": "Energysaver 80", "model_qualifier": "", "winter_efficiency_pct": 85.0, "summer_efficiency_pct": 77.4, "comparative_hot_water_efficiency_pct": 56.5, "output_kw_max": 23.4, "final_year_of_manufacture": 2003, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["003975", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Energysaver 80", "", "41 319 84", "1994", "2003", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "20.5", "23.4", "", "", "85.0", "77.4", "", "56.5", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "88.0", "92.7", "", "", "", "", "91.8"]} +{"pcdb_id": 3976, "brand_name": "Glow-worm", "model_name": "Energysaver 80P", "model_qualifier": "", "winter_efficiency_pct": 86.0, "summer_efficiency_pct": 78.4, "comparative_hot_water_efficiency_pct": 57.2, "output_kw_max": 23.4, "final_year_of_manufacture": 2003, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["003976", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Energysaver 80P", "", "41 319 85", "1994", "2003", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "17.6", "23.4", "", "", "86.0", "78.4", "", "57.2", "", "2", "0", "", "101", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "88.1", "92.9", "", "", "", "", "92.0"]} +{"pcdb_id": 3977, "brand_name": "Glow-worm", "model_name": "Energysaver 70", "model_qualifier": "", "winter_efficiency_pct": 85.0, "summer_efficiency_pct": 77.4, "comparative_hot_water_efficiency_pct": 56.5, "output_kw_max": 20.5, "final_year_of_manufacture": 2002, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["003977", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Energysaver 70", "", "41 319 92", "1994", "2002", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "17.6", "20.5", "", "", "85.0", "77.4", "", "56.5", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "88.0", "92.7", "", "", "", "", "91.8"]} +{"pcdb_id": 3978, "brand_name": "Glow-worm", "model_name": "Energysaver 50e", "model_qualifier": "", "winter_efficiency_pct": 84.5, "summer_efficiency_pct": 76.9, "comparative_hot_water_efficiency_pct": 56.2, "output_kw_max": 14.65, "final_year_of_manufacture": 2002, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["003978", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Energysaver 50e", "", "41 319 94", "1996", "2002", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "14.65", "14.65", "", "", "84.5", "76.9", "", "56.2", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "86.6", "92.1", "", "", "", "", "91.0"]} +{"pcdb_id": 3979, "brand_name": "Glow-worm", "model_name": "Energysaver 60e", "model_qualifier": "", "winter_efficiency_pct": 84.6, "summer_efficiency_pct": 77.0, "comparative_hot_water_efficiency_pct": 56.2, "output_kw_max": 17.58, "final_year_of_manufacture": 2002, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["003979", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Energysaver 60e", "", "41 319 95", "1996", "2002", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "17.58", "17.58", "", "", "84.6", "77.0", "", "56.2", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "86.6", "92.2", "", "", "", "", "91.1"]} +{"pcdb_id": 3980, "brand_name": "Glow-worm", "model_name": "Energysaver 40", "model_qualifier": "", "winter_efficiency_pct": 84.4, "summer_efficiency_pct": 76.8, "comparative_hot_water_efficiency_pct": 56.1, "output_kw_max": 11.72, "final_year_of_manufacture": 2003, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["003980", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Energysaver 40", "", "41 319 69", "1993", "2003", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "8.79", "11.72", "", "", "84.4", "76.8", "", "56.1", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "86.6", "91.9", "", "", "", "", "90.9"]} +{"pcdb_id": 3981, "brand_name": "Glow-worm", "model_name": "Energysaver 50", "model_qualifier": "", "winter_efficiency_pct": 84.5, "summer_efficiency_pct": 76.9, "comparative_hot_water_efficiency_pct": 56.2, "output_kw_max": 14.65, "final_year_of_manufacture": 2002, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["003981", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Energysaver 50", "", "41 319 70", "1993", "2002", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "11.72", "14.65", "", "", "84.5", "76.9", "", "56.2", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "86.6", "92.1", "", "", "", "", "91.0"]} +{"pcdb_id": 3982, "brand_name": "Glow-worm", "model_name": "Energysaver 60", "model_qualifier": "", "winter_efficiency_pct": 84.6, "summer_efficiency_pct": 77.0, "comparative_hot_water_efficiency_pct": 56.2, "output_kw_max": 17.58, "final_year_of_manufacture": 2003, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["003982", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Energysaver 60", "", "41 319 71", "1993", "2003", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "14.65", "17.58", "", "", "84.6", "77.0", "", "56.2", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "86.6", "92.2", "", "", "", "", "91.1"]} +{"pcdb_id": 3983, "brand_name": "Glow-worm", "model_name": "Energysaver 40P", "model_qualifier": "", "winter_efficiency_pct": 84.8, "summer_efficiency_pct": 77.2, "comparative_hot_water_efficiency_pct": 56.4, "output_kw_max": 11.72, "final_year_of_manufacture": 2003, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["003983", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Energysaver 40P", "", "41 319 72", "1993", "2003", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "8.79", "11.72", "", "", "84.8", "77.2", "", "56.4", "", "2", "0", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "86.6", "91.8", "", "", "", "", "90.8"]} +{"pcdb_id": 3984, "brand_name": "Glow-worm", "model_name": "Energysaver 50P", "model_qualifier": "", "winter_efficiency_pct": 84.9, "summer_efficiency_pct": 77.3, "comparative_hot_water_efficiency_pct": 56.4, "output_kw_max": 14.65, "final_year_of_manufacture": 2002, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["003984", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Energysaver 50P", "", "41 319 73", "1993", "2002", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "11.72", "14.65", "", "", "84.9", "77.3", "", "56.4", "", "2", "0", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "86.6", "92.0", "", "", "", "", "91.0"]} +{"pcdb_id": 3985, "brand_name": "Glow-worm", "model_name": "Energysaver 60P", "model_qualifier": "", "winter_efficiency_pct": 84.9, "summer_efficiency_pct": 77.3, "comparative_hot_water_efficiency_pct": 56.5, "output_kw_max": 17.58, "final_year_of_manufacture": 2003, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["003985", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Energysaver 60P", "", "41 319 74", "1993", "2003", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "14.65", "17.58", "", "", "84.9", "77.3", "", "56.5", "", "2", "0", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "86.6", "92.1", "", "", "", "", "91.1"]} +{"pcdb_id": 3986, "brand_name": "Glow-worm", "model_name": "Energysaver 30", "model_qualifier": "", "winter_efficiency_pct": 84.3, "summer_efficiency_pct": 76.7, "comparative_hot_water_efficiency_pct": 56.1, "output_kw_max": 8.79, "final_year_of_manufacture": 2002, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["003986", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Energysaver 30", "", "41 319 78", "1994", "2002", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "8.79", "8.79", "", "", "84.3", "76.7", "", "56.1", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "86.6", "91.6", "", "", "", "", "90.7"]} +{"pcdb_id": 3987, "brand_name": "Glow-worm", "model_name": "Energysaver 30e", "model_qualifier": "", "winter_efficiency_pct": 84.3, "summer_efficiency_pct": 76.7, "comparative_hot_water_efficiency_pct": 56.1, "output_kw_max": 8.79, "final_year_of_manufacture": 2002, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["003987", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Energysaver 30e", "", "41 319 76", "1994", "2002", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "8.79", "8.79", "", "", "84.3", "76.7", "", "56.1", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "86.6", "91.6", "", "", "", "", "90.7"]} +{"pcdb_id": 3988, "brand_name": "Glow-worm", "model_name": "Energysaver 40e", "model_qualifier": "", "winter_efficiency_pct": 84.4, "summer_efficiency_pct": 76.8, "comparative_hot_water_efficiency_pct": 56.1, "output_kw_max": 11.72, "final_year_of_manufacture": 2002, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["003988", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Energysaver 40e", "", "41 319 77", "1994", "2002", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "8.79", "11.72", "", "", "84.4", "76.8", "", "56.1", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "86.6", "91.9", "", "", "", "", "90.9"]} +{"pcdb_id": 3989, "brand_name": "Glow-worm", "model_name": "Swiftflow 100e", "model_qualifier": "", "winter_efficiency_pct": 77.5, "summer_efficiency_pct": 67.4, "comparative_hot_water_efficiency_pct": 47.4, "output_kw_max": 17.6, "final_year_of_manufacture": 1999, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["003989", "000207", "0", "2006/Jan/17 12:55", "Hepworth Heating", "Glow-worm", "Swiftflow 100e", "", "47 -313 -18", "1995", "1999", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "17.6", "17.6", "", "", "77.5", "67.4", "", "47.4", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "78.4", "79.0", "", "", "", "", "78.9"]} +{"pcdb_id": 3990, "brand_name": "Glow-worm", "model_name": "Swiftflow 80e", "model_qualifier": "", "winter_efficiency_pct": 77.5, "summer_efficiency_pct": 67.4, "comparative_hot_water_efficiency_pct": 47.4, "output_kw_max": 17.6, "final_year_of_manufacture": 1999, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["003990", "000207", "0", "2006/Jan/17 12:55", "Hepworth Heating", "Glow-worm", "Swiftflow 80e", "", "47 -313 -17", "1995", "1999", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "17.6", "17.6", "", "", "77.5", "67.4", "", "47.4", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "79.9", "77.5", "", "", "", "", "77.9"]} +{"pcdb_id": 3991, "brand_name": "Glow-worm", "model_name": "Swiftflow 75e", "model_qualifier": "", "winter_efficiency_pct": 77.4, "summer_efficiency_pct": 67.3, "comparative_hot_water_efficiency_pct": 47.3, "output_kw_max": 16.1, "final_year_of_manufacture": 1999, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["003991", "000207", "0", "2006/Jan/17 12:55", "Hepworth Heating", "Glow-worm", "Swiftflow 75e", "", "47 -313 -16", "1995", "1999", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "16.1", "16.1", "", "", "77.4", "67.3", "", "47.3", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "79.6", "77.7", "", "", "", "", "78.0"]} +{"pcdb_id": 3992, "brand_name": "Glow-worm", "model_name": "Swiftflow 120", "model_qualifier": "", "winter_efficiency_pct": 74.0, "summer_efficiency_pct": 63.9, "comparative_hot_water_efficiency_pct": 45.0, "output_kw_max": 23.5, "final_year_of_manufacture": 1999, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["003992", "000207", "0", "2006/Jan/17 12:55", "Hepworth Heating", "Glow-worm", "Swiftflow 120", "", "47 -313 -13", "1994", "1999", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "23.5", "23.5", "", "", "74.0", "63.9", "", "45.0", "", "2", "", "", "104", "2", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "78.7", "79.7", "", "", "", "", "79.6"]} +{"pcdb_id": 3993, "brand_name": "Glow-worm", "model_name": "Swiftflow 125e", "model_qualifier": "", "winter_efficiency_pct": 80.5, "summer_efficiency_pct": 70.4, "comparative_hot_water_efficiency_pct": 49.5, "output_kw_max": 23.5, "final_year_of_manufacture": 2002, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["003993", "000207", "0", "2006/Jan/17 12:55", "Hepworth Heating", "Glow-worm", "Swiftflow 125e", "", "47 -313 -19", "1998", "2002", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "23.5", "23.5", "", "", "80.5", "70.4", "", "49.5", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "80.9", "82.4", "", "", "", "", "82.2"]} +{"pcdb_id": 3994, "brand_name": "Glow-worm", "model_name": "Inset BBU 40", "model_qualifier": "", "winter_efficiency_pct": 76.4, "summer_efficiency_pct": 66.3, "comparative_hot_water_efficiency_pct": 48.4, "output_kw_max": 11.7, "final_year_of_manufacture": 2002, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["003994", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Inset BBU 40", "", "44 047 01", "1998", "2002", "1", "4", "1", "1", "0", "", "", "1", "1", "1", "5.9", "11.7", "", "", "76.4", "66.3", "", "48.4", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "78.2", "77.8", "", "", "", "", "77.8"]} +{"pcdb_id": 3995, "brand_name": "Glow-worm", "model_name": "Inset BBU 50", "model_qualifier": "", "winter_efficiency_pct": 78.5, "summer_efficiency_pct": 68.4, "comparative_hot_water_efficiency_pct": 49.9, "output_kw_max": 14.7, "final_year_of_manufacture": 2002, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["003995", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Inset BBU 50", "", "44 047 02", "1998", "2002", "1", "4", "1", "1", "0", "", "", "1", "1", "1", "11.7", "14.7", "", "", "78.5", "68.4", "", "49.9", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.1", "81.0", "", "", "", "", "80.6"]} +{"pcdb_id": 3996, "brand_name": "Glow-worm", "model_name": "45/2 BBU", "model_qualifier": "", "winter_efficiency_pct": 69.3, "summer_efficiency_pct": 59.2, "comparative_hot_water_efficiency_pct": 43.2, "output_kw_max": 13.8, "final_year_of_manufacture": 2002, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["003996", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "45/2 BBU", "", "44 315 39", "1997", "2002", "1", "4", "1", "1", "0", "", "", "1", "1", "1", "9.5", "13.8", "", "", "69.3", "59.2", "", "43.2", "", "2", "", "", "101", "2", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "76.1", "73.6", "", "", "", "", "74.1"]} +{"pcdb_id": 3997, "brand_name": "Glow-worm", "model_name": "56/2 BBU", "model_qualifier": "", "winter_efficiency_pct": 69.0, "summer_efficiency_pct": 58.9, "comparative_hot_water_efficiency_pct": 43.0, "output_kw_max": 16.5, "final_year_of_manufacture": 2002, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["003997", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "56/2 BBU", "", "44 315 40", "1997", "2002", "1", "4", "1", "1", "0", "", "", "1", "1", "1", "13.8", "16.5", "", "", "69.0", "58.9", "", "43.0", "", "2", "", "", "101", "2", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "75.5", "73.7", "", "", "", "", "74.0"]} +{"pcdb_id": 3998, "brand_name": "Glow-worm", "model_name": "56/3pp BBU", "model_qualifier": "", "winter_efficiency_pct": 75.4, "summer_efficiency_pct": 65.3, "comparative_hot_water_efficiency_pct": 47.7, "output_kw_max": 16.4, "final_year_of_manufacture": 2003, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["003998", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "56/3pp BBU", "", "44 O47 03A", "1999", "2003", "1", "4", "1", "1", "0", "", "", "1", "1", "1", "9.4", "16.4", "", "", "75.4", "65.3", "", "47.7", "", "2", "", "", "101", "2", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "80.5", "81.6", "", "", "", "", "81.4"]} +{"pcdb_id": 3999, "brand_name": "Glow-worm", "model_name": "56/3e BBU", "model_qualifier": "", "winter_efficiency_pct": 79.4, "summer_efficiency_pct": 69.3, "comparative_hot_water_efficiency_pct": 50.7, "output_kw_max": 16.4, "final_year_of_manufacture": 2003, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["003999", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "56/3e BBU", "", "44 047 04A", "1999", "2003", "1", "4", "1", "1", "0", "", "", "1", "1", "1", "9.4", "16.4", "", "", "79.4", "69.3", "", "50.7", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "80.5", "81.6", "", "", "", "", "81.4"]} +{"pcdb_id": 4000, "brand_name": "Glow-worm", "model_name": "Economy Plus 24B", "model_qualifier": "", "winter_efficiency_pct": 76.0, "summer_efficiency_pct": 65.9, "comparative_hot_water_efficiency_pct": 48.2, "output_kw_max": 7.03, "final_year_of_manufacture": 1998, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["004000", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Economy Plus 24B", "", "41- 319- 90", "1992", "1998", "1", "2", "1", "1", "0", "", "", "1", "2", "1", "", "7.03", "", "", "76.0", "65.9", "", "48.2", "", "2", "", "", "101", "2", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.9", "81.4", "", "", "", "", "81.5"]} +{"pcdb_id": 4001, "brand_name": "Glow-worm", "model_name": "Economy Plus 30B", "model_qualifier": "", "winter_efficiency_pct": 72.2, "summer_efficiency_pct": 62.1, "comparative_hot_water_efficiency_pct": 45.4, "output_kw_max": 8.79, "final_year_of_manufacture": 2002, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["004001", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Economy Plus 30B", "", "41- 319- 01", "1992", "2002", "1", "2", "1", "1", "0", "", "", "1", "2", "1", "5.86", "8.79", "", "", "72.2", "62.1", "", "45.4", "", "2", "", "", "101", "2", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "78.0", "77.6", "", "", "", "", "77.7"]} +{"pcdb_id": 4002, "brand_name": "Glow-worm", "model_name": "Economy Plus 40B", "model_qualifier": "", "winter_efficiency_pct": 72.8, "summer_efficiency_pct": 62.7, "comparative_hot_water_efficiency_pct": 45.8, "output_kw_max": 11.72, "final_year_of_manufacture": 2002, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["004002", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Economy Plus 40B", "", "41- 319- 02", "1992", "2002", "1", "2", "1", "1", "0", "", "", "1", "2", "1", "8.79", "11.72", "", "", "72.8", "62.7", "", "45.8", "", "2", "", "", "101", "2", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "78.3", "78.5", "", "", "", "", "78.4"]} +{"pcdb_id": 4003, "brand_name": "Glow-worm", "model_name": "Economy Plus 50B", "model_qualifier": "", "winter_efficiency_pct": 74.0, "summer_efficiency_pct": 63.9, "comparative_hot_water_efficiency_pct": 46.7, "output_kw_max": 14.65, "final_year_of_manufacture": 2002, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["004003", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Economy Plus 50B", "", "41- 319- 03", "1992", "2002", "1", "2", "1", "1", "0", "", "", "1", "2", "1", "11.72", "14.65", "", "", "74.0", "63.9", "", "46.7", "", "2", "", "", "101", "2", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.0", "78.3", "", "", "", "", "78.8"]} +{"pcdb_id": 4004, "brand_name": "Glow-worm", "model_name": "Economy Plus 60B", "model_qualifier": "", "winter_efficiency_pct": 76.5, "summer_efficiency_pct": 66.4, "comparative_hot_water_efficiency_pct": 48.5, "output_kw_max": 17.59, "final_year_of_manufacture": 1998, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["004004", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Economy Plus 60B", "", "41- 319- 04", "1992", "1998", "1", "2", "1", "1", "0", "", "", "1", "2", "1", "14.65", "17.59", "", "", "76.5", "66.4", "", "48.5", "", "2", "", "", "101", "2", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.9", "82.3", "", "", "", "", "82.2"]} +{"pcdb_id": 4005, "brand_name": "Glow-worm", "model_name": "Economy Plus 30C", "model_qualifier": "", "winter_efficiency_pct": 73.3, "summer_efficiency_pct": 63.2, "comparative_hot_water_efficiency_pct": 46.2, "output_kw_max": 8.79, "final_year_of_manufacture": 2002, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["004005", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Economy Plus 30C", "", "41- 319- 37", "1992", "2002", "1", "2", "1", "1", "0", "", "", "1", "1", "1", "5.86", "8.79", "", "", "73.3", "63.2", "", "46.2", "", "2", "", "", "101", "2", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "78.9", "78.9", "", "", "", "", "78.9"]} +{"pcdb_id": 4006, "brand_name": "Glow-worm", "model_name": "Economy Plus 40C", "model_qualifier": "", "winter_efficiency_pct": 72.8, "summer_efficiency_pct": 62.7, "comparative_hot_water_efficiency_pct": 45.8, "output_kw_max": 11.7, "final_year_of_manufacture": 2002, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["004006", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Economy Plus 40C", "", "41- 319- 38", "1992", "2002", "1", "2", "1", "1", "0", "", "", "1", "1", "1", "8.8", "11.7", "", "", "72.8", "62.7", "", "45.8", "", "2", "", "", "101", "2", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "78.7", "78.1", "", "", "", "", "78.2"]} +{"pcdb_id": 4007, "brand_name": "Glow-worm", "model_name": "Economy Plus 50C", "model_qualifier": "", "winter_efficiency_pct": 73.3, "summer_efficiency_pct": 63.2, "comparative_hot_water_efficiency_pct": 46.2, "output_kw_max": 14.65, "final_year_of_manufacture": 2002, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["004007", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Economy Plus 50C", "", "41- 319- 39", "1992", "2002", "1", "2", "1", "1", "0", "", "", "1", "1", "1", "11.72", "14.65", "", "", "73.3", "63.2", "", "46.2", "", "2", "", "", "101", "2", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "78.8", "79.0", "", "", "", "", "79.0"]} +{"pcdb_id": 4008, "brand_name": "Glow-worm", "model_name": "Economy Plus 60C", "model_qualifier": "", "winter_efficiency_pct": 74.7, "summer_efficiency_pct": 64.6, "comparative_hot_water_efficiency_pct": 47.2, "output_kw_max": 17.59, "final_year_of_manufacture": 1998, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["004008", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Economy Plus 60C", "", "41- 319- 40", "1992", "1998", "1", "2", "1", "1", "0", "", "", "1", "1", "1", "14.65", "17.59", "", "", "74.7", "64.6", "", "47.2", "", "2", "", "", "101", "2", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "80.0", "80.5", "", "", "", "", "80.4"]} +{"pcdb_id": 4009, "brand_name": "Glow-worm", "model_name": "Economy Plus 24F", "model_qualifier": "", "winter_efficiency_pct": 78.1, "summer_efficiency_pct": 68.0, "comparative_hot_water_efficiency_pct": 49.7, "output_kw_max": 7.03, "final_year_of_manufacture": 1998, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["004009", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Economy Plus 24F", "", "41- 319- 28", "1992", "1998", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "", "7.03", "", "", "78.1", "68.0", "", "49.7", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.4", "78.1", "", "", "", "", "78.7"]} +{"pcdb_id": 4010, "brand_name": "Glow-worm", "model_name": "Economy Plus 30F", "model_qualifier": "", "winter_efficiency_pct": 76.6, "summer_efficiency_pct": 66.5, "comparative_hot_water_efficiency_pct": 48.5, "output_kw_max": 8.79, "final_year_of_manufacture": 2002, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["004010", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Economy Plus 30F", "", "41- 319- 29", "1992", "2002", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "5.86", "8.79", "", "", "76.6", "66.5", "", "48.5", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "78.5", "77.8", "", "", "", "", "78.0"]} +{"pcdb_id": 4011, "brand_name": "Glow-worm", "model_name": "Economy Plus 40F", "model_qualifier": "", "winter_efficiency_pct": 77.9, "summer_efficiency_pct": 67.8, "comparative_hot_water_efficiency_pct": 49.5, "output_kw_max": 11.72, "final_year_of_manufacture": 2002, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["004011", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Economy Plus 40F", "", "41- 319- 30", "1992", "2002", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "8.79", "11.72", "", "", "77.9", "67.8", "", "49.5", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.9", "79.1", "", "", "", "", "79.3"]} +{"pcdb_id": 4012, "brand_name": "Glow-worm", "model_name": "Economy Plus 50F", "model_qualifier": "", "winter_efficiency_pct": 77.2, "summer_efficiency_pct": 67.1, "comparative_hot_water_efficiency_pct": 49.0, "output_kw_max": 14.65, "final_year_of_manufacture": 2002, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["004012", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Economy Plus 50F", "", "41- 319- 31", "1992", "2002", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "11.72", "14.65", "", "", "77.2", "67.1", "", "49.0", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "78.9", "78.7", "", "", "", "", "78.7"]} +{"pcdb_id": 4013, "brand_name": "Glow-worm", "model_name": "Economy Plus 60F", "model_qualifier": "", "winter_efficiency_pct": 76.7, "summer_efficiency_pct": 66.6, "comparative_hot_water_efficiency_pct": 48.7, "output_kw_max": 17.58, "final_year_of_manufacture": 2002, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["004013", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Economy Plus 60F", "", "41- 319- 63", "1992", "2002", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "14.65", "17.58", "", "", "76.7", "66.6", "", "48.7", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "78.4", "78.3", "", "", "", "", "78.3"]} +{"pcdb_id": 4014, "brand_name": "Glow-worm", "model_name": "Economy Plus 80F", "model_qualifier": "", "winter_efficiency_pct": 78.5, "summer_efficiency_pct": 68.4, "comparative_hot_water_efficiency_pct": 50.0, "output_kw_max": 23.45, "final_year_of_manufacture": 2002, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["004014", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Economy Plus 80F", "", "41- 319- 64", "1992", "2002", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "17.58", "23.45", "", "", "78.5", "68.4", "", "50.0", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.2", "79.1", "", "", "", "", "79.5"]} +{"pcdb_id": 4015, "brand_name": "Glow-worm", "model_name": "Hideaway 40", "model_qualifier": "", "winter_efficiency_pct": 71.7, "summer_efficiency_pct": 61.6, "comparative_hot_water_efficiency_pct": 45.0, "output_kw_max": 11.7, "final_year_of_manufacture": 2003, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["004015", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Hideaway 40", "", "44 313 17", "1997", "2003", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "8.8", "11.7", "", "", "71.7", "61.6", "", "45.0", "", "2", "", "", "101", "2", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "78.6", "76.0", "", "", "", "", "76.5"]} +{"pcdb_id": 4016, "brand_name": "Glow-worm", "model_name": "Hideaway 50", "model_qualifier": "", "winter_efficiency_pct": 71.9, "summer_efficiency_pct": 61.8, "comparative_hot_water_efficiency_pct": 45.1, "output_kw_max": 14.7, "final_year_of_manufacture": 2003, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["004016", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Hideaway 50", "", "44 313 15", "1997", "2003", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "11.7", "14.7", "", "", "71.9", "61.8", "", "45.1", "", "2", "", "", "101", "2", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "78.5", "76.5", "", "", "", "", "76.9"]} +{"pcdb_id": 4017, "brand_name": "Glow-worm", "model_name": "Hideaway 60", "model_qualifier": "", "winter_efficiency_pct": 72.2, "summer_efficiency_pct": 62.1, "comparative_hot_water_efficiency_pct": 45.4, "output_kw_max": 16.7, "final_year_of_manufacture": 2003, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["004017", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Hideaway 60", "", "41 313 13", "1997", "2003", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "14.65", "16.7", "", "", "72.2", "62.1", "", "45.4", "", "2", "", "", "101", "2", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "78.5", "77.1", "", "", "", "", "77.4"]} +{"pcdb_id": 4018, "brand_name": "Glow-worm", "model_name": "Hideaway 70", "model_qualifier": "", "winter_efficiency_pct": 72.7, "summer_efficiency_pct": 62.6, "comparative_hot_water_efficiency_pct": 45.7, "output_kw_max": 20.5, "final_year_of_manufacture": 2003, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["004018", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Hideaway 70", "", "44 313 82", "1997", "2003", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "17.6", "20.5", "", "", "72.7", "62.6", "", "45.7", "", "2", "", "", "101", "2", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "78.7", "77.8", "", "", "", "", "78.0"]} +{"pcdb_id": 4019, "brand_name": "Glow-worm", "model_name": "Hideaway 80", "model_qualifier": "", "winter_efficiency_pct": 72.6, "summer_efficiency_pct": 62.5, "comparative_hot_water_efficiency_pct": 45.7, "output_kw_max": 23.5, "final_year_of_manufacture": 2003, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["004019", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Hideaway 80", "", "44 313 25", "1997", "2003", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "20.5", "23.5", "", "", "72.6", "62.5", "", "45.7", "", "2", "", "", "101", "2", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "78.8", "77.6", "", "", "", "", "77.8"]} +{"pcdb_id": 4020, "brand_name": "Glow-worm", "model_name": "Hideaway 90", "model_qualifier": "", "winter_efficiency_pct": 72.6, "summer_efficiency_pct": 62.5, "comparative_hot_water_efficiency_pct": 45.6, "output_kw_max": 26.4, "final_year_of_manufacture": 2003, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["004020", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Hideaway 90", "", "44 313 84", "1997", "2003", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "23.5", "26.4", "", "", "72.6", "62.5", "", "45.6", "", "2", "", "", "101", "2", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "78.7", "77.7", "", "", "", "", "77.9"]} +{"pcdb_id": 4021, "brand_name": "Glow-worm", "model_name": "Hideaway 100", "model_qualifier": "", "winter_efficiency_pct": 73.0, "summer_efficiency_pct": 62.9, "comparative_hot_water_efficiency_pct": 45.9, "output_kw_max": 29.3, "final_year_of_manufacture": 2003, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["004021", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Hideaway 100", "", "44 313 27", "1997", "2003", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "26.4", "29.3", "", "", "73.0", "62.9", "", "45.9", "", "2", "", "", "101", "2", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "78.9", "78.2", "", "", "", "", "78.3"]} +{"pcdb_id": 4022, "brand_name": "Glow-worm", "model_name": "Hideaway 120", "model_qualifier": "", "winter_efficiency_pct": 73.9, "summer_efficiency_pct": 63.8, "comparative_hot_water_efficiency_pct": 46.6, "output_kw_max": 35.2, "final_year_of_manufacture": 2003, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["004022", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Hideaway 120", "", "44 313 29", "1997", "2003", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "29.3", "35.2", "", "", "73.9", "63.8", "", "46.6", "", "2", "", "", "101", "2", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.6", "79.4", "", "", "", "", "79.4"]} +{"pcdb_id": 4023, "brand_name": "Glow-worm", "model_name": "Hideaway 40B", "model_qualifier": "", "winter_efficiency_pct": 72.4, "summer_efficiency_pct": 62.3, "comparative_hot_water_efficiency_pct": 45.5, "output_kw_max": 11.7, "final_year_of_manufacture": 2003, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["004023", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Hideaway 40B", "", "44 313 16", "1997", "2003", "1", "1", "1", "1", "0", "", "", "1", "2", "1", "8.8", "11.7", "", "", "72.4", "62.3", "", "45.5", "", "2", "", "", "101", "2", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.4", "76.7", "", "", "", "", "77.2"]} +{"pcdb_id": 4024, "brand_name": "Glow-worm", "model_name": "Hideaway 50B", "model_qualifier": "", "winter_efficiency_pct": 72.3, "summer_efficiency_pct": 62.2, "comparative_hot_water_efficiency_pct": 45.5, "output_kw_max": 14.7, "final_year_of_manufacture": 2003, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["004024", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Hideaway 50B", "", "44 313 14", "1997", "2003", "1", "1", "1", "1", "0", "", "", "1", "2", "1", "11.7", "14.7", "", "", "72.3", "62.2", "", "45.5", "", "2", "", "", "101", "2", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "78.1", "77.8", "", "", "", "", "77.8"]} +{"pcdb_id": 4025, "brand_name": "Glow-worm", "model_name": "Hideaway 60B", "model_qualifier": "", "winter_efficiency_pct": 72.6, "summer_efficiency_pct": 62.5, "comparative_hot_water_efficiency_pct": 45.6, "output_kw_max": 16.7, "final_year_of_manufacture": 2003, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["004025", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Hideaway 60B", "", "44 313 12", "1997", "2003", "1", "1", "1", "1", "0", "", "", "1", "2", "1", "14.7", "16.7", "", "", "72.6", "62.5", "", "45.6", "", "2", "", "", "101", "2", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "78.9", "77.4", "", "", "", "", "77.7"]} +{"pcdb_id": 4026, "brand_name": "Glow-worm", "model_name": "Hideaway 70B", "model_qualifier": "", "winter_efficiency_pct": 73.4, "summer_efficiency_pct": 63.3, "comparative_hot_water_efficiency_pct": 46.2, "output_kw_max": 20.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["004026", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Hideaway 70B", "", "44 313 83", "1997", "current", "1", "1", "1", "1", "0", "", "", "1", "2", "1", "17.6", "20.5", "", "", "73.4", "63.3", "", "46.2", "", "2", "", "", "101", "2", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.2", "78.7", "", "", "", "", "78.8"]} +{"pcdb_id": 4027, "brand_name": "Glow-worm", "model_name": "Hideaway 80B", "model_qualifier": "", "winter_efficiency_pct": 73.5, "summer_efficiency_pct": 63.4, "comparative_hot_water_efficiency_pct": 46.3, "output_kw_max": 23.5, "final_year_of_manufacture": 2003, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["004027", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Hideaway 80B", "", "44 313 24", "1997", "2003", "1", "1", "1", "1", "0", "", "", "1", "2", "1", "20.5", "23.5", "", "", "73.5", "63.4", "", "46.3", "", "2", "", "", "101", "2", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.2", "79.0", "", "", "", "", "79.1"]} +{"pcdb_id": 4028, "brand_name": "Glow-worm", "model_name": "Hideaway 90B", "model_qualifier": "", "winter_efficiency_pct": 73.7, "summer_efficiency_pct": 63.6, "comparative_hot_water_efficiency_pct": 46.5, "output_kw_max": 26.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["004028", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Hideaway 90B", "", "44 313 85", "1997", "current", "1", "1", "1", "1", "0", "", "", "1", "2", "1", "23.5", "26.4", "", "", "73.7", "63.6", "", "46.5", "", "2", "", "", "101", "2", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.9", "78.7", "", "", "", "", "79.0"]} +{"pcdb_id": 4029, "brand_name": "Glow-worm", "model_name": "Hideaway 100B", "model_qualifier": "", "winter_efficiency_pct": 73.9, "summer_efficiency_pct": 63.8, "comparative_hot_water_efficiency_pct": 46.6, "output_kw_max": 29.3, "final_year_of_manufacture": 2003, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["004029", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Hideaway 100B", "", "44 313 26", "1997", "2003", "1", "1", "1", "1", "0", "", "", "1", "2", "1", "26.4", "29.3", "", "", "73.9", "63.8", "", "46.6", "", "2", "", "", "101", "2", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.5", "79.5", "", "", "", "", "79.5"]} +{"pcdb_id": 4030, "brand_name": "Glow-worm", "model_name": "Hideaway 120B", "model_qualifier": "", "winter_efficiency_pct": 72.9, "summer_efficiency_pct": 62.8, "comparative_hot_water_efficiency_pct": 45.9, "output_kw_max": 35.2, "final_year_of_manufacture": 2003, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["004030", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Hideaway 120B", "", "44 313 28", "1997", "2003", "1", "1", "1", "1", "0", "", "", "1", "2", "1", "29.3", "35.2", "", "", "72.9", "62.8", "", "45.9", "", "2", "", "", "101", "2", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.5", "77.6", "", "", "", "", "77.9"]} +{"pcdb_id": 4031, "brand_name": "Glow-worm", "model_name": "Micron 120FF", "model_qualifier": "", "winter_efficiency_pct": 79.0, "summer_efficiency_pct": 68.9, "comparative_hot_water_efficiency_pct": 50.4, "output_kw_max": 35.17, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["004031", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Micron 120FF", "", "41 047 23", "1999", "current", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "29.31", "35.17", "", "", "79.0", "68.9", "", "50.4", "", "2", "", "", "101", "1", "1", "97", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.8", "81.5", "", "", "", "", "81.1"]} +{"pcdb_id": 4032, "brand_name": "Glow-worm", "model_name": "Micron 30FF", "model_qualifier": "", "winter_efficiency_pct": 77.5, "summer_efficiency_pct": 67.4, "comparative_hot_water_efficiency_pct": 49.2, "output_kw_max": 8.79, "final_year_of_manufacture": 2002, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["004032", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Micron 30FF", "", "41 047 16", "1999", "2002", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "5.86", "8.79", "", "", "77.5", "67.4", "", "49.2", "", "2", "", "", "101", "1", "1", "66", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.6", "78.6", "", "", "", "", "78.8"]} +{"pcdb_id": 4033, "brand_name": "Glow-worm", "model_name": "Micron 40FF", "model_qualifier": "", "winter_efficiency_pct": 78.2, "summer_efficiency_pct": 68.1, "comparative_hot_water_efficiency_pct": 49.8, "output_kw_max": 11.72, "final_year_of_manufacture": 2002, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["004033", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Micron 40FF", "", "41 047 17", "1999", "2002", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "8.8", "11.72", "", "", "78.2", "68.1", "", "49.8", "", "2", "", "", "101", "1", "1", "66", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "80.4", "79.3", "", "", "", "", "79.5"]} +{"pcdb_id": 4035, "brand_name": "Glow-worm", "model_name": "Micron 60FF", "model_qualifier": "", "winter_efficiency_pct": 78.1, "summer_efficiency_pct": 68.0, "comparative_hot_water_efficiency_pct": 49.7, "output_kw_max": 17.58, "final_year_of_manufacture": 2002, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["004035", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Micron 60FF", "", "41 047 19", "1999", "2002", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "14.65", "17.58", "", "", "78.1", "68.0", "", "49.7", "", "2", "", "", "101", "1", "1", "71", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "80.0", "79.5", "", "", "", "", "79.6"]} +{"pcdb_id": 4036, "brand_name": "Glow-worm", "model_name": "Micron 70FF", "model_qualifier": "", "winter_efficiency_pct": 78.3, "summer_efficiency_pct": 68.2, "comparative_hot_water_efficiency_pct": 49.8, "output_kw_max": 20.51, "final_year_of_manufacture": 2002, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["004036", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Micron 70FF", "", "41 047 20", "1999", "2002", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "17.58", "20.51", "", "", "78.3", "68.2", "", "49.8", "", "2", "", "", "101", "1", "1", "81", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.8", "79.9", "", "", "", "", "79.9"]} +{"pcdb_id": 4037, "brand_name": "Glow-worm", "model_name": "Micron100FF", "model_qualifier": "", "winter_efficiency_pct": 78.4, "summer_efficiency_pct": 68.3, "comparative_hot_water_efficiency_pct": 49.9, "output_kw_max": 29.31, "final_year_of_manufacture": 2002, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["004037", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Micron100FF", "", "41 047 22", "1999", "2002", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "23.45", "29.31", "", "", "78.4", "68.3", "", "49.9", "", "2", "", "", "101", "1", "1", "71", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "80.2", "79.8", "", "", "", "", "79.9"]} +{"pcdb_id": 4038, "brand_name": "Glow-worm", "model_name": "Micron 80FF", "model_qualifier": "", "winter_efficiency_pct": 78.1, "summer_efficiency_pct": 68.0, "comparative_hot_water_efficiency_pct": 49.7, "output_kw_max": 23.45, "final_year_of_manufacture": 2002, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["004038", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Micron 80FF", "", "41 047 21", "1999", "2002", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "20.51", "23.45", "", "", "78.1", "68.0", "", "49.7", "", "2", "", "", "101", "1", "1", "81", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.9", "79.5", "", "", "", "", "79.6"]} +{"pcdb_id": 4039, "brand_name": "Glow-worm", "model_name": "Ultimate 50BF/LP", "model_qualifier": "", "winter_efficiency_pct": 75.7, "summer_efficiency_pct": 65.6, "comparative_hot_water_efficiency_pct": 47.9, "output_kw_max": 14.65, "final_year_of_manufacture": 2002, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["004039", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Ultimate 50BF/LP", "", "", "1993", "2002", "2", "2", "1", "1", "0", "", "", "1", "2", "1", "14.65", "14.65", "", "", "75.7", "65.6", "", "47.9", "", "2", "0", "", "101", "2", "1", "1", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.6", "81.0", "", "", "", "", "81.1"]} +{"pcdb_id": 4040, "brand_name": "Glow-worm", "model_name": "Ultimate 80FF/LP", "model_qualifier": "", "winter_efficiency_pct": 80.7, "summer_efficiency_pct": 70.6, "comparative_hot_water_efficiency_pct": 51.6, "output_kw_max": 21.98, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["004040", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Ultimate 80FF/LP", "", "", "1993", "current", "2", "2", "1", "1", "0", "", "", "1", "2", "2", "21.98", "21.98", "", "", "80.7", "70.6", "", "51.6", "", "2", "0", "", "101", "1", "1", "71", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.2", "82.4", "", "", "", "", "82.4"]} +{"pcdb_id": 4041, "brand_name": "Glow-worm", "model_name": "Ultimate 60FF/LP", "model_qualifier": "", "winter_efficiency_pct": 78.4, "summer_efficiency_pct": 68.3, "comparative_hot_water_efficiency_pct": 49.9, "output_kw_max": 17.59, "final_year_of_manufacture": 2002, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["004041", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Ultimate 60FF/LP", "", "", "1993", "2002", "2", "2", "1", "1", "0", "", "", "1", "2", "2", "17.59", "17.59", "", "", "78.4", "68.3", "", "49.9", "", "2", "0", "", "101", "1", "1", "71", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "80.4", "79.6", "", "", "", "", "79.7"]} +{"pcdb_id": 4042, "brand_name": "Glow-worm", "model_name": "Ultimate 50FF/LP", "model_qualifier": "", "winter_efficiency_pct": 81.0, "summer_efficiency_pct": 70.9, "comparative_hot_water_efficiency_pct": 51.8, "output_kw_max": 14.65, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["004042", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Ultimate 50FF/LP", "", "", "1993", "current", "2", "2", "1", "1", "0", "", "", "1", "2", "2", "14.65", "14.65", "", "", "81.0", "70.9", "", "51.8", "", "2", "0", "", "101", "1", "1", "56", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.4", "82.7", "", "", "", "", "82.7"]} +{"pcdb_id": 4043, "brand_name": "Glow-worm", "model_name": "Ultimate 40FF/LP", "model_qualifier": "", "winter_efficiency_pct": 78.9, "summer_efficiency_pct": 68.8, "comparative_hot_water_efficiency_pct": 50.3, "output_kw_max": 11.72, "final_year_of_manufacture": 2002, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["004043", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Ultimate 40FF/LP", "", "", "1993", "2002", "2", "2", "1", "1", "0", "", "", "1", "2", "2", "11.72", "11.72", "", "", "78.9", "68.8", "", "50.3", "", "2", "0", "", "101", "1", "1", "56", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "80.8", "80.3", "", "", "", "", "80.4"]} +{"pcdb_id": 4044, "brand_name": "Glow-worm", "model_name": "Ultimate 30FF/LP", "model_qualifier": "", "winter_efficiency_pct": 78.9, "summer_efficiency_pct": 68.8, "comparative_hot_water_efficiency_pct": 50.3, "output_kw_max": 8.79, "final_year_of_manufacture": 2002, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["004044", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Ultimate 30FF/LP", "", "", "1993", "2002", "2", "2", "1", "1", "0", "", "", "1", "2", "2", "8.79", "8.79", "", "", "78.9", "68.8", "", "50.3", "", "2", "0", "", "101", "1", "1", "56", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "80.0", "81.0", "", "", "", "", "80.9"]} +{"pcdb_id": 4045, "brand_name": "Glow-worm", "model_name": "Ultimate 100FF", "model_qualifier": "", "winter_efficiency_pct": 78.4, "summer_efficiency_pct": 68.3, "comparative_hot_water_efficiency_pct": 49.9, "output_kw_max": 29.31, "final_year_of_manufacture": 2002, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["004045", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Ultimate 100FF", "", "41 319 61", "1994", "2002", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "23.45", "29.31", "", "", "78.4", "68.3", "", "49.9", "", "2", "", "", "101", "1", "1", "71", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "80.2", "79.8", "", "", "", "", "79.9"]} +{"pcdb_id": 4046, "brand_name": "Glow-worm", "model_name": "Ultimate 80FF", "model_qualifier": "", "winter_efficiency_pct": 77.2, "summer_efficiency_pct": 67.1, "comparative_hot_water_efficiency_pct": 49.0, "output_kw_max": 23.45, "final_year_of_manufacture": 2002, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["004046", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Ultimate 80FF", "", "41 319 60", "1993", "2002", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "20.52", "23.45", "", "", "77.2", "67.1", "", "49.0", "", "2", "", "", "101", "1", "1", "71", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.2", "78.5", "", "", "", "", "78.6"]} +{"pcdb_id": 4047, "brand_name": "Glow-worm", "model_name": "Ultimate 50FF", "model_qualifier": "", "winter_efficiency_pct": 76.9, "summer_efficiency_pct": 66.8, "comparative_hot_water_efficiency_pct": 48.8, "output_kw_max": 14.65, "final_year_of_manufacture": 2002, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["004047", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Ultimate 50FF", "", "41 319 58", "1993", "2002", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "11.72", "14.65", "", "", "76.9", "66.8", "", "48.8", "", "2", "", "", "101", "1", "1", "56", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "78.7", "78.3", "", "", "", "", "78.4"]} +{"pcdb_id": 4048, "brand_name": "Glow-worm", "model_name": "Ultimate 60FF", "model_qualifier": "", "winter_efficiency_pct": 77.5, "summer_efficiency_pct": 67.4, "comparative_hot_water_efficiency_pct": 49.2, "output_kw_max": 17.59, "final_year_of_manufacture": 2002, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["004048", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Ultimate 60FF", "", "41 319 59", "1993", "2002", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "14.65", "17.59", "", "", "77.5", "67.4", "", "49.2", "", "2", "", "", "101", "1", "1", "71", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "78.8", "79.3", "", "", "", "", "79.2"]} +{"pcdb_id": 4049, "brand_name": "Glow-worm", "model_name": "Ultimate 120FF", "model_qualifier": "", "winter_efficiency_pct": 79.0, "summer_efficiency_pct": 68.9, "comparative_hot_water_efficiency_pct": 50.4, "output_kw_max": 35.17, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["004049", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Ultimate 120FF", "", "41 319 75", "1994", "current", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "29.3", "35.17", "", "", "79.0", "68.9", "", "50.4", "", "2", "", "", "101", "1", "1", "97", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.8", "81.5", "", "", "", "", "81.1"]} +{"pcdb_id": 4050, "brand_name": "Glow-worm", "model_name": "Ultimate 70FF", "model_qualifier": "", "winter_efficiency_pct": 78.0, "summer_efficiency_pct": 67.9, "comparative_hot_water_efficiency_pct": 49.6, "output_kw_max": 20.52, "final_year_of_manufacture": 2002, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["004050", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Ultimate 70FF", "", "41 319 59", "1994", "2002", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "17.58", "20.52", "", "", "78.0", "67.9", "", "49.6", "", "2", "", "", "101", "1", "1", "71", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.6", "79.6", "", "", "", "", "79.6"]} +{"pcdb_id": 4051, "brand_name": "Glow-worm", "model_name": "Ultimate 30FF", "model_qualifier": "", "winter_efficiency_pct": 80.8, "summer_efficiency_pct": 70.7, "comparative_hot_water_efficiency_pct": 51.6, "output_kw_max": 8.79, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["004051", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Ultimate 30FF", "", "41 319 56", "1993", "current", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "5.86", "8.79", "", "", "80.8", "70.7", "", "51.6", "", "2", "", "", "101", "1", "1", "56", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.4", "82.4", "", "", "", "", "82.4"]} +{"pcdb_id": 4052, "brand_name": "Glow-worm", "model_name": "Ultimate 40FF", "model_qualifier": "", "winter_efficiency_pct": 76.3, "summer_efficiency_pct": 66.2, "comparative_hot_water_efficiency_pct": 48.4, "output_kw_max": 11.72, "final_year_of_manufacture": 2002, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["004052", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Ultimate 40FF", "", "41 319 57", "1993", "2002", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "8.79", "11.72", "", "", "76.3", "66.2", "", "48.4", "", "2", "", "", "101", "1", "1", "56", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.0", "76.9", "", "", "", "", "77.3"]} +{"pcdb_id": 4053, "brand_name": "Glow-worm", "model_name": "Fuelsaver Complheat 40", "model_qualifier": "", "winter_efficiency_pct": 77.6, "summer_efficiency_pct": 67.5, "comparative_hot_water_efficiency_pct": 49.3, "output_kw_max": 11.7, "final_year_of_manufacture": 2002, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["004053", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Fuelsaver Complheat 40", "", "41-319-20", "1991", "2002", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "8.8", "11.7", "", "", "77.6", "67.5", "", "49.3", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.6", "78.7", "", "", "", "", "78.9"]} +{"pcdb_id": 4054, "brand_name": "Glow-worm", "model_name": "Fuelsaver Complheat 65", "model_qualifier": "", "winter_efficiency_pct": 80.0, "summer_efficiency_pct": 69.9, "comparative_hot_water_efficiency_pct": 51.0, "output_kw_max": 19.1, "final_year_of_manufacture": 2002, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["004054", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Fuelsaver Complheat 65", "", "41-319-21", "1991", "2002", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "16.1", "19.1", "", "", "80.0", "69.9", "", "51.0", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.3", "81.9", "", "", "", "", "81.8"]} +{"pcdb_id": 4055, "brand_name": "Glow-worm", "model_name": "Fuelsaver Complheat 30", "model_qualifier": "", "winter_efficiency_pct": 77.4, "summer_efficiency_pct": 67.3, "comparative_hot_water_efficiency_pct": 49.2, "output_kw_max": 8.8, "final_year_of_manufacture": 2002, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["004055", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Fuelsaver Complheat 30", "", "41-319-14", "1991", "2002", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "5.9", "8.8", "", "", "77.4", "67.3", "", "49.2", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "80.1", "77.9", "", "", "", "", "78.3"]} +{"pcdb_id": 4056, "brand_name": "Glow-worm", "model_name": "Fuelsaver Complheat 55", "model_qualifier": "", "winter_efficiency_pct": 77.3, "summer_efficiency_pct": 67.2, "comparative_hot_water_efficiency_pct": 49.1, "output_kw_max": 16.1, "final_year_of_manufacture": 2002, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["004056", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Fuelsaver Complheat 55", "", "41-319-19", "1991", "2002", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "11.7", "16.1", "", "", "77.3", "67.2", "", "49.1", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.3", "78.6", "", "", "", "", "78.7"]} +{"pcdb_id": 4057, "brand_name": "Glow-worm", "model_name": "Fuelsaver Complheat 80", "model_qualifier": "", "winter_efficiency_pct": 80.1, "summer_efficiency_pct": 70.0, "comparative_hot_water_efficiency_pct": 51.1, "output_kw_max": 23.4, "final_year_of_manufacture": 2002, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["004057", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Fuelsaver Complheat 80", "", "41-319-18", "1991", "2002", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "19.1", "23.4", "", "", "80.1", "70.0", "", "51.1", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "80.9", "82.5", "", "", "", "", "82.2"]} +{"pcdb_id": 4058, "brand_name": "Glow-worm", "model_name": "Compact 75e", "model_qualifier": "", "winter_efficiency_pct": 78.4, "summer_efficiency_pct": 68.3, "comparative_hot_water_efficiency_pct": 48.0, "output_kw_max": 16.1, "final_year_of_manufacture": 2003, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["004058", "000207", "0", "2006/Jan/17 12:55", "Hepworth Heating", "Glow-worm", "Compact 75e", "", "47-047-06A", "1999", "2003", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "16.1", "16.1", "", "", "78.4", "68.3", "", "48.0", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.0", "78.1", "", "", "", "", "78.7"]} +{"pcdb_id": 4059, "brand_name": "Glow-worm", "model_name": "Compact 80e", "model_qualifier": "", "winter_efficiency_pct": 78.7, "summer_efficiency_pct": 68.6, "comparative_hot_water_efficiency_pct": 48.2, "output_kw_max": 17.6, "final_year_of_manufacture": 2002, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["004059", "000207", "0", "2006/Jan/17 12:55", "Hepworth Heating", "Glow-worm", "Compact 80e", "", "47-047-07A", "1999", "2002", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "17.6", "17.6", "", "", "78.7", "68.6", "", "48.2", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.5", "78.2", "", "", "", "", "78.8"]} +{"pcdb_id": 4060, "brand_name": "Glow-worm", "model_name": "Compact 80p", "model_qualifier": "", "winter_efficiency_pct": 73.1, "summer_efficiency_pct": 63.0, "comparative_hot_water_efficiency_pct": 44.3, "output_kw_max": 17.6, "final_year_of_manufacture": 2002, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["004060", "000207", "0", "2006/Jan/17 12:55", "Hepworth Heating", "Glow-worm", "Compact 80p", "", "47-047-04A", "1999", "2002", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "17.6", "17.6", "", "", "73.1", "63.0", "", "44.3", "", "2", "", "", "104", "2", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "78.9", "77.7", "", "", "", "", "77.9"]} +{"pcdb_id": 4061, "brand_name": "Glow-worm", "model_name": "Compact 100p", "model_qualifier": "", "winter_efficiency_pct": 72.5, "summer_efficiency_pct": 62.4, "comparative_hot_water_efficiency_pct": 43.9, "output_kw_max": 17.6, "final_year_of_manufacture": 2002, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["004061", "000207", "0", "2006/Jan/17 12:55", "Hepworth Heating", "Glow-worm", "Compact 100p", "", "47-047-05A", "1999", "2002", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "17.6", "17.6", "", "", "72.5", "62.4", "", "43.9", "", "2", "", "", "104", "2", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "79.6", "75.9", "", "", "", "", "76.6"]} +{"pcdb_id": 4062, "brand_name": "Glow-worm", "model_name": "Compact 75p", "model_qualifier": "", "winter_efficiency_pct": 73.0, "summer_efficiency_pct": 62.9, "comparative_hot_water_efficiency_pct": 44.2, "output_kw_max": 16.1, "final_year_of_manufacture": 2002, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["004062", "000207", "0", "2006/Jan/17 12:55", "Hepworth Heating", "Glow-worm", "Compact 75p", "", "47-047-03A", "1999", "2002", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "16.1", "16.1", "", "", "73.0", "62.9", "", "44.2", "", "2", "", "", "104", "2", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "79.8", "76.6", "", "", "", "", "77.2"]} +{"pcdb_id": 4063, "brand_name": "Glow-worm", "model_name": "Compact 100e", "model_qualifier": "", "winter_efficiency_pct": 79.1, "summer_efficiency_pct": 69.0, "comparative_hot_water_efficiency_pct": 48.5, "output_kw_max": 17.6, "final_year_of_manufacture": 2002, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["004063", "000207", "0", "2006/Jan/17 12:55", "Hepworth Heating", "Glow-worm", "Compact 100e", "", "47-047-08A", "1999", "2002", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "17.6", "17.6", "", "", "79.1", "69.0", "", "48.5", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "83.0", "77.8", "", "", "", "", "78.7"]} +{"pcdb_id": 4064, "brand_name": "Hepworth Heating", "model_name": "Halstead Buckingham III BF120", "model_qualifier": "", "winter_efficiency_pct": 72.9, "summer_efficiency_pct": 62.8, "comparative_hot_water_efficiency_pct": 45.9, "output_kw_max": 35.2, "final_year_of_manufacture": 2003, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["004064", "000019", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Hepworth Heating", "Halstead Buckingham III BF120", "", "41.333.72", "1997", "2003", "1", "1", "1", "1", "0", "", "", "1", "2", "1", "29.3", "35.2", "", "", "72.9", "62.8", "", "45.9", "", "2", "", "", "101", "2", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.5", "77.6", "", "", "", "", "77.9"]} +{"pcdb_id": 4065, "brand_name": "Hepworth Heating", "model_name": "Halstead Buckingham III BF100", "model_qualifier": "", "winter_efficiency_pct": 73.9, "summer_efficiency_pct": 63.8, "comparative_hot_water_efficiency_pct": 46.6, "output_kw_max": 29.3, "final_year_of_manufacture": 2003, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["004065", "000019", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Hepworth Heating", "Halstead Buckingham III BF100", "", "41.333.71", "1997", "2003", "1", "1", "1", "1", "0", "", "", "1", "2", "1", "26.4", "29.3", "", "", "73.9", "63.8", "", "46.6", "", "2", "", "", "101", "2", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.5", "79.5", "", "", "", "", "79.5"]} +{"pcdb_id": 4066, "brand_name": "Hepworth Heating", "model_name": "Halstead Buckingham III BF80", "model_qualifier": "", "winter_efficiency_pct": 73.5, "summer_efficiency_pct": 63.4, "comparative_hot_water_efficiency_pct": 46.3, "output_kw_max": 23.5, "final_year_of_manufacture": 2003, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["004066", "000019", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Hepworth Heating", "Halstead Buckingham III BF80", "", "41.333.70", "1997", "2003", "1", "1", "1", "1", "0", "", "", "1", "2", "1", "20.5", "23.5", "", "", "73.5", "63.4", "", "46.3", "", "2", "", "", "101", "2", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.2", "79.0", "", "", "", "", "79.1"]} +{"pcdb_id": 4067, "brand_name": "Hepworth Heating", "model_name": "Halstead Buckingham III BF70", "model_qualifier": "", "winter_efficiency_pct": 73.4, "summer_efficiency_pct": 63.3, "comparative_hot_water_efficiency_pct": 46.2, "output_kw_max": 20.5, "final_year_of_manufacture": 2003, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["004067", "000019", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Hepworth Heating", "Halstead Buckingham III BF70", "", "41.333.69", "1997", "2003", "1", "1", "1", "1", "0", "", "", "1", "2", "1", "17.6", "20.5", "", "", "73.4", "63.3", "", "46.2", "", "2", "", "", "101", "2", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.2", "78.7", "", "", "", "", "78.8"]} +{"pcdb_id": 4068, "brand_name": "Hepworth Heating", "model_name": "Halstead Buckingham III BF 60", "model_qualifier": "", "winter_efficiency_pct": 72.6, "summer_efficiency_pct": 62.5, "comparative_hot_water_efficiency_pct": 45.6, "output_kw_max": 16.7, "final_year_of_manufacture": 2003, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["004068", "000019", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Hepworth Heating", "Halstead Buckingham III BF 60", "", "41.333.68", "1997", "2003", "1", "1", "1", "1", "0", "", "", "1", "2", "1", "14.7", "16.7", "", "", "72.6", "62.5", "", "45.6", "", "2", "", "", "101", "2", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "78.9", "77.4", "", "", "", "", "77.7"]} +{"pcdb_id": 4069, "brand_name": "Hepworth Heating", "model_name": "Halstead Buckingham III BF50", "model_qualifier": "", "winter_efficiency_pct": 72.3, "summer_efficiency_pct": 62.2, "comparative_hot_water_efficiency_pct": 45.5, "output_kw_max": 14.7, "final_year_of_manufacture": 2003, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["004069", "000019", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Hepworth Heating", "Halstead Buckingham III BF50", "", "41 333 67", "1997", "2003", "1", "1", "1", "1", "0", "", "", "1", "2", "1", "11.7", "14.7", "", "", "72.3", "62.2", "", "45.5", "", "2", "", "", "101", "2", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "78.1", "77.8", "", "", "", "", "77.8"]} +{"pcdb_id": 4070, "brand_name": "Hepworth Heating", "model_name": "Halstead Buckingham III BF40", "model_qualifier": "", "winter_efficiency_pct": 72.4, "summer_efficiency_pct": 62.3, "comparative_hot_water_efficiency_pct": 45.5, "output_kw_max": 11.7, "final_year_of_manufacture": 2003, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["004070", "000019", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Hepworth Heating", "Halstead Buckingham III BF40", "", "41 333 66", "1997", "2003", "1", "1", "1", "1", "0", "", "", "1", "2", "1", "8.8", "11.7", "", "", "72.4", "62.3", "", "45.5", "", "2", "", "", "101", "2", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.4", "76.7", "", "", "", "", "77.2"]} +{"pcdb_id": 4071, "brand_name": "Hepworth Heating", "model_name": "Halstead Buckingham III CF120", "model_qualifier": "", "winter_efficiency_pct": 73.9, "summer_efficiency_pct": 63.8, "comparative_hot_water_efficiency_pct": 46.6, "output_kw_max": 35.2, "final_year_of_manufacture": 2003, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["004071", "000019", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Hepworth Heating", "Halstead Buckingham III CF120", "", "41.333.65", "1997", "2003", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "29.3", "35.2", "", "", "73.9", "63.8", "", "46.6", "", "2", "", "", "101", "2", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.6", "79.4", "", "", "", "", "79.4"]} +{"pcdb_id": 4072, "brand_name": "Hepworth Heating", "model_name": "Halstead Buckingham III CF100", "model_qualifier": "", "winter_efficiency_pct": 73.0, "summer_efficiency_pct": 62.9, "comparative_hot_water_efficiency_pct": 45.9, "output_kw_max": 29.3, "final_year_of_manufacture": 2003, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["004072", "000019", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Hepworth Heating", "Halstead Buckingham III CF100", "", "41.333.64", "1997", "2003", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "26.4", "29.3", "", "", "73.0", "62.9", "", "45.9", "", "2", "", "", "101", "2", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "78.9", "78.2", "", "", "", "", "78.3"]} +{"pcdb_id": 4073, "brand_name": "Hepworth Heating", "model_name": "Halstead Buckingham III CF80", "model_qualifier": "", "winter_efficiency_pct": 72.6, "summer_efficiency_pct": 62.5, "comparative_hot_water_efficiency_pct": 45.7, "output_kw_max": 23.5, "final_year_of_manufacture": 2003, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["004073", "000019", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Hepworth Heating", "Halstead Buckingham III CF80", "", "41.333.63", "1997", "2003", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "20.5", "23.5", "", "", "72.6", "62.5", "", "45.7", "", "2", "", "", "101", "2", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "78.8", "77.6", "", "", "", "", "77.8"]} +{"pcdb_id": 4074, "brand_name": "Hepworth Heating", "model_name": "Halstead Buckingham III CF70", "model_qualifier": "", "winter_efficiency_pct": 72.7, "summer_efficiency_pct": 62.6, "comparative_hot_water_efficiency_pct": 45.7, "output_kw_max": 20.5, "final_year_of_manufacture": 2003, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["004074", "000019", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Hepworth Heating", "Halstead Buckingham III CF70", "", "41.333.62", "1997", "2003", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "17.6", "20.5", "", "", "72.7", "62.6", "", "45.7", "", "2", "", "", "101", "2", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "78.7", "77.8", "", "", "", "", "78.0"]} +{"pcdb_id": 4075, "brand_name": "Hepworth Heating", "model_name": "Halstead Buckingham III CF60", "model_qualifier": "", "winter_efficiency_pct": 72.2, "summer_efficiency_pct": 62.1, "comparative_hot_water_efficiency_pct": 45.4, "output_kw_max": 16.7, "final_year_of_manufacture": 2003, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["004075", "000019", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Hepworth Heating", "Halstead Buckingham III CF60", "", "41.333.61", "1997", "2003", "1", "1", "1", "1", "0", "", "", "1", "2", "1", "14.65", "16.7", "", "", "72.2", "62.1", "", "45.4", "", "2", "", "", "101", "2", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "78.5", "77.1", "", "", "", "", "77.4"]} +{"pcdb_id": 4076, "brand_name": "Hepworth Heating", "model_name": "Halstead Buckingham III CF50", "model_qualifier": "", "winter_efficiency_pct": 71.9, "summer_efficiency_pct": 61.8, "comparative_hot_water_efficiency_pct": 45.1, "output_kw_max": 14.7, "final_year_of_manufacture": 2003, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["004076", "000019", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Hepworth Heating", "Halstead Buckingham III CF50", "", "41 333 60", "1997", "2003", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "11.7", "14.7", "", "", "71.9", "61.8", "", "45.1", "", "2", "", "", "101", "2", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "78.5", "76.5", "", "", "", "", "76.9"]} +{"pcdb_id": 4077, "brand_name": "Hepworth Heating", "model_name": "Halstead Buckingham III CF40", "model_qualifier": "", "winter_efficiency_pct": 71.7, "summer_efficiency_pct": 61.6, "comparative_hot_water_efficiency_pct": 45.0, "output_kw_max": 11.7, "final_year_of_manufacture": 2003, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["004077", "000019", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Hepworth Heating", "Halstead Buckingham III CF40", "", "44 333 59", "1997", "2003", "1", "1", "1", "1", "0", "", "", "1", "2", "1", "8.8", "11.7", "", "", "71.7", "61.6", "", "45.0", "", "2", "", "", "101", "2", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "78.6", "76.0", "", "", "", "", "76.5"]} +{"pcdb_id": 4078, "brand_name": "Saunier Duval", "model_name": "Xeon 80ff", "model_qualifier": "", "winter_efficiency_pct": 77.2, "summer_efficiency_pct": 67.1, "comparative_hot_water_efficiency_pct": 49.0, "output_kw_max": 23.45, "final_year_of_manufacture": 2003, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["004078", "000206", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Saunier Duval", "Xeon 80ff", "", "", "1999", "2003", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "20.52", "23.45", "", "", "77.2", "67.1", "", "49.0", "", "2", "", "", "101", "1", "1", "71", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.2", "78.5", "", "", "", "", "78.6"]} +{"pcdb_id": 4081, "brand_name": "Saunier Duval", "model_name": "Xeon40ff", "model_qualifier": "", "winter_efficiency_pct": 76.3, "summer_efficiency_pct": 66.2, "comparative_hot_water_efficiency_pct": 48.4, "output_kw_max": 11.72, "final_year_of_manufacture": 2003, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["004081", "000206", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Saunier Duval", "Xeon40ff", "", "", "1999", "2003", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "8.79", "11.72", "", "", "76.3", "66.2", "", "48.4", "", "2", "", "", "101", "1", "1", "56", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.0", "76.9", "", "", "", "", "77.3"]} +{"pcdb_id": 4082, "brand_name": "Saunier Duval", "model_name": "Xeon 30ff", "model_qualifier": "", "winter_efficiency_pct": 80.8, "summer_efficiency_pct": 70.7, "comparative_hot_water_efficiency_pct": 51.6, "output_kw_max": 8.79, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["004082", "000206", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Saunier Duval", "Xeon 30ff", "", "", "1999", "current", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "5.86", "8.79", "", "", "80.8", "70.7", "", "51.6", "", "2", "", "", "101", "1", "1", "56", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.4", "82.4", "", "", "", "", "82.4"]} +{"pcdb_id": 4083, "brand_name": "Glow-worm", "model_name": "Ultimate 30BF", "model_qualifier": "", "winter_efficiency_pct": 73.9, "summer_efficiency_pct": 63.8, "comparative_hot_water_efficiency_pct": 46.6, "output_kw_max": 8.79, "final_year_of_manufacture": 2002, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["004083", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Ultimate 30BF", "", "41 319 51", "1993", "2002", "1", "2", "1", "1", "0", "", "", "1", "2", "1", "5.86", "8.79", "", "", "73.9", "63.8", "", "46.6", "", "2", "", "", "101", "2", "1", "1", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.6", "79.5", "", "", "", "", "79.5"]} +{"pcdb_id": 4084, "brand_name": "Glow-worm", "model_name": "Ultimate 40BF", "model_qualifier": "", "winter_efficiency_pct": 73.0, "summer_efficiency_pct": 62.9, "comparative_hot_water_efficiency_pct": 46.0, "output_kw_max": 11.72, "final_year_of_manufacture": 2002, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["004084", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Ultimate 40BF", "", "41 319 52", "1993", "2002", "1", "2", "1", "1", "0", "", "", "1", "2", "1", "8.79", "11.72", "", "", "73.0", "62.9", "", "46.0", "", "2", "", "", "101", "2", "1", "1", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.1", "78.1", "", "", "", "", "78.3"]} +{"pcdb_id": 4085, "brand_name": "Glow-worm", "model_name": "Ultimate 50BF", "model_qualifier": "", "winter_efficiency_pct": 74.0, "summer_efficiency_pct": 63.9, "comparative_hot_water_efficiency_pct": 46.6, "output_kw_max": 14.65, "final_year_of_manufacture": 2002, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["004085", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Ultimate 50BF", "", "41 319 53", "1993", "2002", "1", "2", "1", "1", "0", "", "", "1", "2", "1", "11.72", "14.65", "", "", "74.0", "63.9", "", "46.6", "", "2", "", "", "101", "2", "1", "1", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.6", "79.5", "", "", "", "", "79.5"]} +{"pcdb_id": 4086, "brand_name": "Glow-worm", "model_name": "Ultimate 60BF", "model_qualifier": "", "winter_efficiency_pct": 76.5, "summer_efficiency_pct": 66.4, "comparative_hot_water_efficiency_pct": 48.5, "output_kw_max": 17.58, "final_year_of_manufacture": 2003, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["004086", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Ultimate 60BF", "", "41 319 54", "1993", "2003", "1", "2", "1", "1", "0", "", "", "1", "2", "1", "14.65", "17.58", "", "", "76.5", "66.4", "", "48.5", "", "2", "", "", "101", "2", "1", "1", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.7", "81.5", "", "", "", "", "81.8"]} +{"pcdb_id": 4092, "brand_name": "Glow-worm", "model_name": "Swiftflow 75", "model_qualifier": "Honeywell valve", "winter_efficiency_pct": 72.3, "summer_efficiency_pct": 62.2, "comparative_hot_water_efficiency_pct": 43.7, "output_kw_max": 16.1, "final_year_of_manufacture": 1999, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["004092", "000207", "0", "2006/Jan/17 12:55", "Hepworth Heating", "Glow-worm", "Swiftflow 75", "Honeywell valve", "47 -313 -14", "1994", "1999", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "16.1", "16.1", "", "", "72.3", "62.2", "", "43.7", "", "2", "", "", "104", "2", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "79.0", "76.0", "", "", "", "", "76.5"]} +{"pcdb_id": 4093, "brand_name": "Glow-worm", "model_name": "Swiftflow 80", "model_qualifier": "Honeywell valve", "winter_efficiency_pct": 74.0, "summer_efficiency_pct": 63.9, "comparative_hot_water_efficiency_pct": 45.0, "output_kw_max": 17.6, "final_year_of_manufacture": 1999, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["004093", "000207", "0", "2006/Jan/17 12:55", "Hepworth Heating", "Glow-worm", "Swiftflow 80", "Honeywell valve", "47 -313 -10", "1992", "1999", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "17.6", "17.6", "", "", "74.0", "63.9", "", "45.0", "", "2", "", "", "104", "2", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "79.9", "78.6", "", "", "", "", "78.8"]} +{"pcdb_id": 4094, "brand_name": "Glow-worm", "model_name": "Swiftflow 100", "model_qualifier": "Honeywell valve", "winter_efficiency_pct": 71.6, "summer_efficiency_pct": 61.5, "comparative_hot_water_efficiency_pct": 43.2, "output_kw_max": 17.6, "final_year_of_manufacture": 1999, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["004094", "000207", "0", "2006/Jan/17 12:55", "Hepworth Heating", "Glow-worm", "Swiftflow 100", "Honeywell valve", "47 -313 -08", "1992", "1999", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "17.6", "17.6", "", "", "71.6", "61.5", "", "43.2", "", "2", "", "", "104", "2", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "77.9", "75.6", "", "", "", "", "76.0"]} +{"pcdb_id": 4095, "brand_name": "Glow-worm", "model_name": "Swiftflow 75", "model_qualifier": "SIT valve", "winter_efficiency_pct": 72.3, "summer_efficiency_pct": 62.2, "comparative_hot_water_efficiency_pct": 43.7, "output_kw_max": 16.1, "final_year_of_manufacture": 1999, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["004095", "000207", "0", "2006/Jan/17 12:55", "Hepworth Heating", "Glow-worm", "Swiftflow 75", "SIT valve", "47 -313 -15", "1994", "1999", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "16.1", "16.1", "", "", "72.3", "62.2", "", "43.7", "", "2", "", "", "104", "2", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "79.0", "76.0", "", "", "", "", "76.5"]} +{"pcdb_id": 4096, "brand_name": "Glow-worm", "model_name": "Swiftflow 80", "model_qualifier": "SIT valve", "winter_efficiency_pct": 74.0, "summer_efficiency_pct": 63.9, "comparative_hot_water_efficiency_pct": 45.0, "output_kw_max": 17.6, "final_year_of_manufacture": 1999, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["004096", "000207", "0", "2006/Jan/17 12:55", "Hepworth Heating", "Glow-worm", "Swiftflow 80", "SIT valve", "47 -313 -09", "1992", "1999", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "17.6", "17.6", "", "", "74.0", "63.9", "", "45.0", "", "2", "", "", "104", "2", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "79.9", "78.6", "", "", "", "", "78.8"]} +{"pcdb_id": 4097, "brand_name": "Glow-worm", "model_name": "Swiftflow 100", "model_qualifier": "SIT valve", "winter_efficiency_pct": 71.6, "summer_efficiency_pct": 61.5, "comparative_hot_water_efficiency_pct": 43.2, "output_kw_max": 17.6, "final_year_of_manufacture": 1999, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["004097", "000207", "0", "2006/Jan/17 12:55", "Hepworth Heating", "Glow-worm", "Swiftflow 100", "SIT valve", "47 -313 -07", "1992", "1999", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "17.6", "17.6", "", "", "71.6", "61.5", "", "43.2", "", "2", "", "", "104", "2", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "77.9", "75.6", "", "", "", "", "76.0"]} +{"pcdb_id": 4098, "brand_name": "GAH Heating Products", "model_name": "E50/80", "model_qualifier": "Select", "winter_efficiency_pct": 81.8, "summer_efficiency_pct": 70.1, "comparative_hot_water_efficiency_pct": 51.2, "output_kw_max": 23.4, "final_year_of_manufacture": 2002, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["004098", "000051", "0", "2012/Mar/27 10:12", "GAH Heating Products", "GAH Heating Products", "E50/80", "Select", "BWE50/80", "1994", "2002", "4", "2", "2", "1", "0", "", "", "1", "2", "2", "14.7", "23.4", "", "", "81.8", "70.1", "", "51.2", "", "2", "", "", "201", "1", "1", "22", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "83.3", "80.4", "", "", "", "", "80.9"]} +{"pcdb_id": 4099, "brand_name": "GAH Heating Products", "model_name": "I40/50", "model_qualifier": "Select", "winter_efficiency_pct": 82.7, "summer_efficiency_pct": 71.0, "comparative_hot_water_efficiency_pct": 51.9, "output_kw_max": 14.7, "final_year_of_manufacture": 2002, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["004099", "000051", "0", "2012/Mar/27 10:12", "GAH Heating Products", "GAH Heating Products", "I40/50", "Select", "BWI40/50", "1996", "2002", "4", "2", "1", "1", "0", "", "", "1", "2", "2", "11.7", "14.7", "", "", "82.7", "71.0", "", "51.9", "", "2", "", "", "201", "1", "1", "22", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "83.3", "82.2", "", "", "", "", "82.4"]} +{"pcdb_id": 4100, "brand_name": "GAH Heating Products", "model_name": "I50/80", "model_qualifier": "Select", "winter_efficiency_pct": 83.3, "summer_efficiency_pct": 71.6, "comparative_hot_water_efficiency_pct": 52.3, "output_kw_max": 23.4, "final_year_of_manufacture": 2002, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["004100", "000051", "0", "2012/Mar/27 10:12", "GAH Heating Products", "GAH Heating Products", "I50/80", "Select", "BWI50/80", "1994", "2002", "4", "2", "1", "1", "0", "", "", "1", "2", "2", "14.7", "23.4", "", "", "83.3", "71.6", "", "52.3", "", "2", "", "", "201", "1", "1", "22", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "84.5", "82.2", "", "", "", "", "82.6"]} +{"pcdb_id": 4101, "brand_name": "GAH Heating Products", "model_name": "40/60", "model_qualifier": "Option", "winter_efficiency_pct": 82.9, "summer_efficiency_pct": 71.2, "comparative_hot_water_efficiency_pct": 52.0, "output_kw_max": 18.2, "final_year_of_manufacture": 2002, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["004101", "000051", "0", "2012/Mar/27 10:12", "GAH Heating Products", "GAH Heating Products", "40/60", "Option", "BF040/60", "1995", "2002", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "11.7", "18.2", "", "", "82.9", "71.2", "", "52.0", "", "2", "", "", "201", "1", "1", "22", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "83.5", "82.4", "", "", "", "", "82.6"]} +{"pcdb_id": 4102, "brand_name": "HEB Boilers", "model_name": "60/80", "model_qualifier": "Option", "winter_efficiency_pct": 81.9, "summer_efficiency_pct": 70.2, "comparative_hot_water_efficiency_pct": 51.3, "output_kw_max": 23.4, "final_year_of_manufacture": 2002, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["004102", "000051", "0", "2012/Mar/27 10:12", "HEB Boilers", "HEB Boilers", "60/80", "Option", "BF060/80", "1995", "2002", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "18.2", "23.4", "", "", "81.9", "70.2", "", "51.3", "", "2", "", "", "201", "1", "1", "22", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.7", "82.1", "", "", "", "", "82.0"]} +{"pcdb_id": 4103, "brand_name": "GAH Heating Products", "model_name": "80/95", "model_qualifier": "Option", "winter_efficiency_pct": 81.8, "summer_efficiency_pct": 70.1, "comparative_hot_water_efficiency_pct": 51.2, "output_kw_max": 27.8, "final_year_of_manufacture": 2002, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["004103", "000051", "0", "2012/Mar/27 10:12", "GAH Heating Products", "GAH Heating Products", "80/95", "Option", "BFSO80/95", "1995", "2002", "4", "1", "1", "1", "0", "", "", "1", "2", "1", "23.4", "27.8", "", "", "81.8", "70.1", "", "51.2", "", "2", "", "", "201", "1", "1", "22", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.7", "82.0", "", "", "", "", "81.9"]} +{"pcdb_id": 4104, "brand_name": "GAH Heating Products", "model_name": "100/150", "model_qualifier": "Option", "winter_efficiency_pct": 82.8, "summer_efficiency_pct": 71.1, "comparative_hot_water_efficiency_pct": 52.0, "output_kw_max": 43.9, "final_year_of_manufacture": 2002, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["004104", "000051", "0", "2012/Mar/27 10:12", "GAH Heating Products", "GAH Heating Products", "100/150", "Option", "BF0100/150", "1995", "2002", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "29.3", "43.9", "", "", "82.8", "71.1", "", "52.0", "", "2", "", "", "201", "1", "1", "22", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.8", "82.8", "", "", "", "", "82.8"]} +{"pcdb_id": 4105, "brand_name": "GAH Heating Products", "model_name": "40/60", "model_qualifier": "Select", "winter_efficiency_pct": 82.9, "summer_efficiency_pct": 71.2, "comparative_hot_water_efficiency_pct": 52.0, "output_kw_max": 18.2, "final_year_of_manufacture": 2002, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["004105", "000051", "0", "2012/Mar/27 10:12", "GAH Heating Products", "GAH Heating Products", "40/60", "Select", "BFS40/60", "1993", "2002", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "11.7", "18.2", "", "", "82.9", "71.2", "", "52.0", "", "2", "", "", "201", "1", "1", "22", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "83.5", "82.4", "", "", "", "", "82.6"]} +{"pcdb_id": 4106, "brand_name": "GAH Heating Products", "model_name": "60/80", "model_qualifier": "Select", "winter_efficiency_pct": 82.9, "summer_efficiency_pct": 71.2, "comparative_hot_water_efficiency_pct": 52.0, "output_kw_max": 18.2, "final_year_of_manufacture": 2002, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["004106", "000051", "0", "2012/Mar/27 10:12", "GAH Heating Products", "GAH Heating Products", "60/80", "Select", "BFS60/80", "1993", "2002", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "11.7", "18.2", "", "", "82.9", "71.2", "", "52.0", "", "2", "", "", "201", "1", "1", "22", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "83.5", "82.4", "", "", "", "", "82.6"]} +{"pcdb_id": 4107, "brand_name": "GAH Heating Products", "model_name": "80/95", "model_qualifier": "Select", "winter_efficiency_pct": 81.8, "summer_efficiency_pct": 70.1, "comparative_hot_water_efficiency_pct": 51.2, "output_kw_max": 27.8, "final_year_of_manufacture": 2002, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["004107", "000051", "0", "2012/Mar/27 10:12", "GAH Heating Products", "GAH Heating Products", "80/95", "Select", "BFS80/95", "1993", "2002", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "23.4", "27.8", "", "", "81.8", "70.1", "", "51.2", "", "2", "", "", "201", "1", "1", "22", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.7", "82.0", "", "", "", "", "81.9"]} +{"pcdb_id": 4108, "brand_name": "GAH Heating Products", "model_name": "100/150", "model_qualifier": "Select", "winter_efficiency_pct": 82.8, "summer_efficiency_pct": 71.1, "comparative_hot_water_efficiency_pct": 52.0, "output_kw_max": 43.9, "final_year_of_manufacture": 2002, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["004108", "000051", "0", "2012/Mar/27 10:12", "GAH Heating Products", "GAH Heating Products", "100/150", "Select", "BFS100/150", "1993", "2002", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "29.3", "43.9", "", "", "82.8", "71.1", "", "52.0", "", "2", "", "", "201", "1", "1", "22", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.8", "82.8", "", "", "", "", "82.8"]} +{"pcdb_id": 4109, "brand_name": "GAH Heating Products", "model_name": "140/190", "model_qualifier": "Select", "winter_efficiency_pct": 83.3, "summer_efficiency_pct": 71.6, "comparative_hot_water_efficiency_pct": 52.3, "output_kw_max": 55.7, "final_year_of_manufacture": 2002, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["004109", "000051", "0", "2012/Mar/27 10:12", "GAH Heating Products", "GAH Heating Products", "140/190", "Select", "BFS140/190", "1993", "2002", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "41", "55.7", "", "", "83.3", "71.6", "", "52.3", "", "2", "", "", "201", "1", "1", "38", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "84.3", "82.4", "", "", "", "", "82.7"]} +{"pcdb_id": 4110, "brand_name": "GAH Heating Products", "model_name": "190/240", "model_qualifier": "Select", "winter_efficiency_pct": 82.0, "summer_efficiency_pct": 70.3, "comparative_hot_water_efficiency_pct": 51.4, "output_kw_max": null, "final_year_of_manufacture": 2002, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["004110", "000051", "0", "2012/Mar/27 10:12", "GAH Heating Products", "GAH Heating Products", "190/240", "Select", "BFS190/240", "1998", "2002", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "55.7", ">70kW", "", "", "82.0", "70.3", "", "51.4", "", "2", "", "", "201", "1", "1", "40", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.4", "81.7", "", "", "", "", "81.8"]} +{"pcdb_id": 4111, "brand_name": "GAH Heating Products", "model_name": "E40/50", "model_qualifier": "Select", "winter_efficiency_pct": 82.7, "summer_efficiency_pct": 71.0, "comparative_hot_water_efficiency_pct": 51.9, "output_kw_max": 14.7, "final_year_of_manufacture": 2002, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["004111", "000051", "0", "2012/Mar/27 10:12", "GAH Heating Products", "GAH Heating Products", "E40/50", "Select", "BWE40/50", "1996", "2002", "4", "2", "2", "1", "0", "", "", "1", "2", "2", "11.7", "14.7", "", "", "82.7", "71.0", "", "51.9", "", "2", "", "", "201", "1", "1", "22", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "83.3", "82.2", "", "", "", "", "82.4"]} +{"pcdb_id": 4112, "brand_name": "Saunier Duval", "model_name": "Xeon 30ff/LP", "model_qualifier": "", "winter_efficiency_pct": 78.9, "summer_efficiency_pct": 68.8, "comparative_hot_water_efficiency_pct": 50.3, "output_kw_max": 8.79, "final_year_of_manufacture": 2003, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["004112", "000206", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Saunier Duval", "Xeon 30ff/LP", "", "", "1999", "2003", "2", "2", "1", "1", "0", "", "", "1", "2", "2", "8.79", "8.79", "", "", "78.9", "68.8", "", "50.3", "", "2", "0", "", "101", "1", "1", "56", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "80.0", "81.0", "", "", "", "", "80.9"]} +{"pcdb_id": 4113, "brand_name": "Saunier Duval", "model_name": "Xeon 40ff/LP", "model_qualifier": "", "winter_efficiency_pct": 78.9, "summer_efficiency_pct": 68.8, "comparative_hot_water_efficiency_pct": 50.3, "output_kw_max": 11.72, "final_year_of_manufacture": 2003, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["004113", "000206", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Saunier Duval", "Xeon 40ff/LP", "", "", "1999", "2003", "2", "2", "1", "1", "0", "", "", "1", "2", "2", "11.72", "11.72", "", "", "78.9", "68.8", "", "50.3", "", "2", "0", "", "101", "1", "1", "56", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "80.8", "80.3", "", "", "", "", "80.4"]} +{"pcdb_id": 4114, "brand_name": "Saunier Duval", "model_name": "Xeon 60ff/LP", "model_qualifier": "", "winter_efficiency_pct": 78.4, "summer_efficiency_pct": 68.3, "comparative_hot_water_efficiency_pct": 49.9, "output_kw_max": 17.59, "final_year_of_manufacture": 2003, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["004114", "000206", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Saunier Duval", "Xeon 60ff/LP", "", "", "1999", "2003", "2", "2", "1", "1", "0", "", "", "1", "2", "2", "17.59", "17.59", "", "", "78.4", "68.3", "", "49.9", "", "2", "0", "", "101", "1", "1", "71", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "80.4", "79.6", "", "", "", "", "79.7"]} +{"pcdb_id": 4115, "brand_name": "Saunier Duval", "model_name": "Xeon 80ff/LP", "model_qualifier": "", "winter_efficiency_pct": 80.7, "summer_efficiency_pct": 70.6, "comparative_hot_water_efficiency_pct": 51.6, "output_kw_max": 21.98, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["004115", "000206", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Saunier Duval", "Xeon 80ff/LP", "", "", "1999", "current", "2", "2", "1", "1", "0", "", "", "1", "2", "2", "21.98", "21.98", "", "", "80.7", "70.6", "", "51.6", "", "2", "0", "", "101", "1", "1", "71", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.2", "82.4", "", "", "", "", "82.4"]} +{"pcdb_id": 4116, "brand_name": "Saunier Duval", "model_name": "50ff/LP", "model_qualifier": "", "winter_efficiency_pct": 81.0, "summer_efficiency_pct": 70.9, "comparative_hot_water_efficiency_pct": 51.8, "output_kw_max": 14.65, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["004116", "000206", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Saunier Duval", "50ff/LP", "", "", "1999", "current", "2", "2", "1", "1", "0", "", "", "1", "2", "2", "14.65", "14.65", "", "", "81.0", "70.9", "", "51.8", "", "2", "0", "", "101", "1", "1", "56", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.4", "82.7", "", "", "", "", "82.7"]} +{"pcdb_id": 4118, "brand_name": "Eco Hometec (UK)", "model_name": "EC38S", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 56.0, "output_kw_max": 46.0, "final_year_of_manufacture": 2006, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["004118", "000014", "0", "2006/Feb/22 12:39", "Eco Hometec (UK)", "Eco Hometec (UK)", "EC38S", "", "", "1995", "2006", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "46", "46", "", "", "88.3", "79.7", "", "56.0", "", "2", "", "", "104", "1", "2", "60", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "97.5", "", "", "", "", "95.7"]} +{"pcdb_id": 4122, "brand_name": "Eco Hometec (UK)", "model_name": "EC38H", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 38.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["004122", "000014", "0", "2012/Mar/27 10:12", "Eco Hometec (UK)", "Eco Hometec (UK)", "EC38H", "", "", "1995", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "38", "38", "", "", "88.3", "79.3", "", "57.9", "", "2", "", "", "102", "1", "2", "60", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "97.5", "", "", "", "", "95.7"]} +{"pcdb_id": 4124, "brand_name": "Eco Hometec (UK)", "model_name": "EC31S", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 56.2, "output_kw_max": 36.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["004124", "000014", "0", "2006/Jan/17 12:31", "Eco Hometec (UK)", "Eco Hometec (UK)", "EC31S", "", "", "1995", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "36", "36", "", "", "88.5", "79.9", "", "56.2", "", "2", "", "", "104", "1", "2", "60", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.1", "98.1", "", "", "", "", "96.2"]} +{"pcdb_id": 4126, "brand_name": "Eco Hometec (UK)", "model_name": "EC31HS", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 31.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["004126", "000014", "0", "2012/Mar/27 10:12", "Eco Hometec (UK)", "Eco Hometec (UK)", "EC31HS", "", "", "1995", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "31", "31", "", "", "88.5", "79.5", "", "58.1", "", "2", "", "", "102", "1", "2", "60", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.1", "98.1", "", "", "", "", "96.2"]} +{"pcdb_id": 4128, "brand_name": "Eco Hometec (UK)", "model_name": "EC31H", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 31.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["004128", "000014", "0", "2012/Mar/27 10:12", "Eco Hometec (UK)", "Eco Hometec (UK)", "EC31H", "", "", "1995", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "31", "31", "", "", "88.5", "79.5", "", "58.1", "", "2", "", "", "102", "1", "2", "60", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.1", "98.1", "", "", "", "", "96.2"]} +{"pcdb_id": 4130, "brand_name": "Eco Hometec (UK)", "model_name": "EC23S", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 56.2, "output_kw_max": 28.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["004130", "000014", "0", "2006/Jan/17 12:31", "Eco Hometec (UK)", "Eco Hometec (UK)", "EC23S", "", "", "1995", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28", "28", "", "", "88.5", "79.9", "", "56.2", "", "2", "", "", "104", "1", "2", "60", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.7", "98.1", "", "", "", "", "96.1"]} +{"pcdb_id": 4132, "brand_name": "Eco Hometec (UK)", "model_name": "EC23HS", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 23.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["004132", "000014", "0", "2012/Mar/27 10:12", "Eco Hometec (UK)", "Eco Hometec (UK)", "EC23HS", "", "", "1995", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "23", "23", "", "", "88.5", "79.5", "", "58.0", "", "2", "", "", "102", "1", "2", "60", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.7", "98.1", "", "", "", "", "96.1"]} +{"pcdb_id": 4134, "brand_name": "Eco Hometec (UK)", "model_name": "EC23H", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 23.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["004134", "000014", "0", "2012/Mar/27 10:12", "Eco Hometec (UK)", "Eco Hometec (UK)", "EC23H", "", "", "1995", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "23", "23", "", "", "88.5", "79.5", "", "58.0", "", "2", "", "", "102", "1", "2", "60", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.7", "98.1", "", "", "", "", "96.1"]} +{"pcdb_id": 4136, "brand_name": "Eco Hometec (UK)", "model_name": "EC16S", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 55.8, "output_kw_max": 22.0, "final_year_of_manufacture": 2006, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["004136", "000014", "0", "2006/Feb/22 12:38", "Eco Hometec (UK)", "Eco Hometec (UK)", "EC16S", "", "", "1995", "2006", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "22", "22", "", "", "88.0", "79.4", "", "55.8", "", "2", "", "", "104", "1", "2", "60", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.6", "96.9", "", "", "", "", "95.1"]} +{"pcdb_id": 4138, "brand_name": "Eco Hometec (UK)", "model_name": "EC16HS", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 16.0, "final_year_of_manufacture": 2006, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["004138", "000014", "0", "2012/Mar/27 10:12", "Eco Hometec (UK)", "Eco Hometec (UK)", "EC16HS", "", "", "1995", "2006", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "16", "16", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "60", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.6", "96.9", "", "", "", "", "95.1"]} +{"pcdb_id": 4140, "brand_name": "Eco Hometec (UK)", "model_name": "EC16H", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 16.0, "final_year_of_manufacture": 2006, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["004140", "000014", "0", "2012/Mar/27 10:12", "Eco Hometec (UK)", "Eco Hometec (UK)", "EC16H", "", "", "1995", "2006", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "16", "16", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "60", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.6", "96.9", "", "", "", "", "95.1"]} +{"pcdb_id": 4141, "brand_name": "Boulter", "model_name": "Bonus", "model_qualifier": "40/65", "winter_efficiency_pct": 86.6, "summer_efficiency_pct": 74.9, "comparative_hot_water_efficiency_pct": 54.7, "output_kw_max": 19.0, "final_year_of_manufacture": 2005, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["004141", "000041", "0", "2012/Mar/27 10:12", "Boulter Boilers", "Boulter", "Bonus", "40/65", "0001099950", "1999", "2005", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "11.7", "19", "", "", "86.6", "74.9", "", "54.7", "", "2", "", "", "201", "1", "1", "115", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.0", "87.0", "", "", "", "", "87.0"]} +{"pcdb_id": 4142, "brand_name": "Boulter", "model_name": "Bonus", "model_qualifier": "65/95", "winter_efficiency_pct": 84.6, "summer_efficiency_pct": 72.9, "comparative_hot_water_efficiency_pct": 53.2, "output_kw_max": 27.8, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["004142", "000041", "0", "2012/Mar/27 10:12", "Boulter Boilers", "Boulter", "Bonus", "65/95", "", "1999", "2001", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "19", "27.8", "", "", "84.6", "72.9", "", "53.2", "", "2", "", "", "201", "1", "1", "115", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "83.9", "85.3", "", "", "", "", "85.0"]} +{"pcdb_id": 4143, "brand_name": "Boulter", "model_name": "Camray 5", "model_qualifier": "40/65", "winter_efficiency_pct": 86.6, "summer_efficiency_pct": 74.9, "comparative_hot_water_efficiency_pct": 54.7, "output_kw_max": 19.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["004143", "000041", "0", "2012/Mar/27 10:12", "Boulter Boilers", "Boulter", "Camray 5", "40/65", "0001099837", "1998", "current", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "11.7", "19", "", "", "86.6", "74.9", "", "54.7", "", "2", "", "", "201", "1", "1", "115", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.0", "87.0", "", "", "", "", "87.0"]} +{"pcdb_id": 4144, "brand_name": "Boulter", "model_name": "Camray 5 Utility", "model_qualifier": "40/65 Utility", "winter_efficiency_pct": 86.6, "summer_efficiency_pct": 74.9, "comparative_hot_water_efficiency_pct": 54.7, "output_kw_max": 19.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["004144", "000041", "0", "2012/Mar/27 10:12", "Boulter Boilers", "Boulter", "Camray 5 Utility", "40/65 Utility", "0001099840", "1998", "current", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "11.7", "19", "", "", "86.6", "74.9", "", "54.7", "", "2", "", "", "201", "1", "1", "115", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.0", "87.0", "", "", "", "", "87.0"]} +{"pcdb_id": 4145, "brand_name": "Boulter", "model_name": "Camray 5 System", "model_qualifier": "40/65 System", "winter_efficiency_pct": 86.6, "summer_efficiency_pct": 74.9, "comparative_hot_water_efficiency_pct": 54.7, "output_kw_max": 19.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["004145", "000041", "0", "2012/Mar/27 10:12", "Boulter Boilers", "Boulter", "Camray 5 System", "40/65 System", "0001039943", "1999", "current", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "11.7", "19", "", "", "86.6", "74.9", "", "54.7", "", "2", "", "", "201", "1", "1", "115", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.0", "87.0", "", "", "", "", "87.0"]} +{"pcdb_id": 4146, "brand_name": "Boulter", "model_name": "Camray 5", "model_qualifier": "65/95", "winter_efficiency_pct": 84.6, "summer_efficiency_pct": 72.9, "comparative_hot_water_efficiency_pct": 53.2, "output_kw_max": 27.8, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["004146", "000041", "0", "2012/Mar/27 10:12", "Boulter Boilers", "Boulter", "Camray 5", "65/95", "0001099838", "1998", "2001", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "19", "27.8", "", "", "84.6", "72.9", "", "53.2", "", "2", "", "", "201", "1", "1", "115", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "83.9", "85.3", "", "", "", "", "85.0"]} +{"pcdb_id": 4147, "brand_name": "Boulter", "model_name": "Camray 5 Utility", "model_qualifier": "65/95 Utility", "winter_efficiency_pct": 84.6, "summer_efficiency_pct": 72.9, "comparative_hot_water_efficiency_pct": 53.2, "output_kw_max": 27.8, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["004147", "000041", "0", "2012/Mar/27 10:12", "Boulter Boilers", "Boulter", "Camray 5 Utility", "65/95 Utility", "0001099841", "1998", "2001", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "19", "27.8", "", "", "84.6", "72.9", "", "53.2", "", "2", "", "", "201", "1", "1", "115", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "83.9", "85.3", "", "", "", "", "85.0"]} +{"pcdb_id": 4148, "brand_name": "Boulter", "model_name": "Camray 5 System", "model_qualifier": "65/95 System", "winter_efficiency_pct": 84.6, "summer_efficiency_pct": 72.9, "comparative_hot_water_efficiency_pct": 53.2, "output_kw_max": 27.8, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["004148", "000041", "0", "2012/Mar/27 10:12", "Boulter Boilers", "Boulter", "Camray 5 System", "65/95 System", "0001039944", "1999", "2001", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "19", "27.8", "", "", "84.6", "72.9", "", "53.2", "", "2", "", "", "201", "1", "1", "115", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "83.9", "85.3", "", "", "", "", "85.0"]} +{"pcdb_id": 4149, "brand_name": "Boulter", "model_name": "Camray 5", "model_qualifier": "100/130", "winter_efficiency_pct": 81.2, "summer_efficiency_pct": 69.5, "comparative_hot_water_efficiency_pct": 50.8, "output_kw_max": 38.1, "final_year_of_manufacture": 2000, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["004149", "000041", "0", "2012/Mar/27 10:12", "Boulter Boilers", "Boulter", "Camray 5", "100/130", "0001099838", "1998", "2000", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "29.3", "38.1", "", "", "81.2", "69.5", "", "50.8", "", "2", "", "", "201", "1", "1", "115", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.8", "80.7", "", "", "", "", "80.9"]} +{"pcdb_id": 4150, "brand_name": "Boulter", "model_name": "Camray 5 Utility", "model_qualifier": "100/130 Utility", "winter_efficiency_pct": 81.2, "summer_efficiency_pct": 69.5, "comparative_hot_water_efficiency_pct": 50.8, "output_kw_max": 38.1, "final_year_of_manufacture": 2000, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["004150", "000041", "0", "2012/Mar/27 10:12", "Boulter Boilers", "Boulter", "Camray 5 Utility", "100/130 Utility", "0001099842", "1998", "2000", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "29.3", "38.1", "", "", "81.2", "69.5", "", "50.8", "", "2", "", "", "201", "1", "1", "115", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.8", "80.7", "", "", "", "", "80.9"]} +{"pcdb_id": 4151, "brand_name": "Boulter", "model_name": "Camray 5 System", "model_qualifier": "100/130 System", "winter_efficiency_pct": 81.2, "summer_efficiency_pct": 69.5, "comparative_hot_water_efficiency_pct": 50.8, "output_kw_max": 38.1, "final_year_of_manufacture": 2000, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["004151", "000041", "0", "2012/Mar/27 10:12", "Boulter Boilers", "Boulter", "Camray 5 System", "100/130 System", "0001039945", "1999", "2000", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "29.3", "38.1", "", "", "81.2", "69.5", "", "50.8", "", "2", "", "", "201", "1", "1", "115", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.8", "80.7", "", "", "", "", "80.9"]} +{"pcdb_id": 4152, "brand_name": "Boulter", "model_name": "Classic", "model_qualifier": "50/70", "winter_efficiency_pct": 80.6, "summer_efficiency_pct": 68.9, "comparative_hot_water_efficiency_pct": 50.3, "output_kw_max": 20.5, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["004152", "000041", "0", "2012/Mar/27 10:12", "Boulter Boilers", "Boulter", "Classic", "50/70", "0001039946", "1999", "2001", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "14.7", "20.5", "", "", "80.6", "68.9", "", "50.3", "", "2", "", "", "201", "1", "1", "115", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.0", "79.2", "", "", "", "", "79.7"]} +{"pcdb_id": 4153, "brand_name": "Boulter", "model_name": "Classic", "model_qualifier": "70/90", "winter_efficiency_pct": 81.4, "summer_efficiency_pct": 69.7, "comparative_hot_water_efficiency_pct": 50.9, "output_kw_max": 26.4, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["004153", "000041", "0", "2012/Mar/27 10:12", "Boulter Boilers", "Boulter", "Classic", "70/90", "0001039947", "1999", "2001", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "20.5", "26.4", "", "", "81.4", "69.7", "", "50.9", "", "2", "", "", "201", "1", "1", "115", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.7", "81.1", "", "", "", "", "81.3"]} +{"pcdb_id": 4154, "brand_name": "Boulter", "model_name": "Classic", "model_qualifier": "95/130", "winter_efficiency_pct": 86.6, "summer_efficiency_pct": 74.9, "comparative_hot_water_efficiency_pct": 54.7, "output_kw_max": 38.1, "final_year_of_manufacture": 2005, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["004154", "000041", "0", "2012/Mar/27 10:12", "Boulter Boilers", "Boulter", "Classic", "95/130", "0001039948", "1999", "2005", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "27.8", "38.1", "", "", "86.6", "74.9", "", "54.7", "", "2", "", "", "201", "1", "1", "145", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.0", "88.9", "", "", "", "", "88.4"]} +{"pcdb_id": 4155, "brand_name": "Boulter", "model_name": "Classic", "model_qualifier": "135/165", "winter_efficiency_pct": 85.2, "summer_efficiency_pct": 73.5, "comparative_hot_water_efficiency_pct": 53.7, "output_kw_max": 48.4, "final_year_of_manufacture": 2005, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["004155", "000041", "0", "2012/Mar/27 10:12", "Boulter Boilers", "Boulter", "Classic", "135/165", "0001039949", "1999", "2005", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "39.6", "48.4", "", "", "85.2", "73.5", "", "53.7", "", "2", "", "", "201", "1", "1", "145", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "83.4", "87.0", "", "", "", "", "86.3"]} +{"pcdb_id": 4156, "brand_name": "Boulter", "model_name": "Camray 3", "model_qualifier": "135/175", "winter_efficiency_pct": 86.2, "summer_efficiency_pct": 74.5, "comparative_hot_water_efficiency_pct": 54.4, "output_kw_max": 51.0, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["004156", "000041", "0", "2012/Mar/27 10:12", "Boulter Boilers", "Boulter", "Camray 3", "135/175", "", "1991", "2001", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "40", "51", "", "", "86.2", "74.5", "", "54.4", "", "2", "", "", "201", "1", "1", "200", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.3", "87.9", "", "", "", "", "87.4"]} +{"pcdb_id": 4157, "brand_name": "Boulter", "model_name": "Camray 5", "model_qualifier": "Combi", "winter_efficiency_pct": 82.7, "summer_efficiency_pct": 74.6, "comparative_hot_water_efficiency_pct": 35.0, "output_kw_max": 27.8, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 1, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["004157", "000041", "0", "2024/Jan/31 10:17", "Boulter Boilers", "Boulter", "Camray 5", "Combi", "", "1999", "2001", "4", "1", "1", "2", "0", "", "", "1", "2", "2", "27.8", "27.8", "", "", "82.7", "74.6", "", "35.0", "", "2", "", "", "203", "1", "1", "145", "0", "1", "1", "0", "40", "0", "15", "3", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "83.9", "85.3", "", "", "", "", "85.0"]} +{"pcdb_id": 4158, "brand_name": "Boulter", "model_name": "Camray", "model_qualifier": "Combi plus", "winter_efficiency_pct": 79.4, "summer_efficiency_pct": 71.3, "comparative_hot_water_efficiency_pct": 29.8, "output_kw_max": 26.4, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 1, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["004158", "000041", "0", "2024/Jan/31 10:17", "Boulter Boilers", "Boulter", "Camray", "Combi plus", "", "1997", "2001", "4", "1", "1", "2", "0", "", "", "1", "2", "2", "26.4", "26.4", "", "", "79.4", "71.3", "", "29.8", "", "2", "", "", "203", "1", "1", "145", "0", "1", "1", "0", "71", "0", "15", "3", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "83.0", "79.6", "", "", "", "", "80.3"]} +{"pcdb_id": 4159, "brand_name": "Boulter", "model_name": "Compact", "model_qualifier": "50/70", "winter_efficiency_pct": 82.7, "summer_efficiency_pct": 71.0, "comparative_hot_water_efficiency_pct": 51.9, "output_kw_max": 20.0, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["004159", "000041", "0", "2012/Mar/27 10:12", "Boulter Boilers", "Boulter", "Compact", "50/70", "", "1994", "2001", "4", "2", "1", "1", "0", "", "", "1", "2", "2", "15", "20", "", "", "82.7", "71.0", "", "51.9", "", "2", "", "", "201", "1", "1", "125", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.6", "82.8", "", "", "", "", "82.8"]} +{"pcdb_id": 4160, "brand_name": "Boulter", "model_name": "Camray", "model_qualifier": "15/19 External", "winter_efficiency_pct": 81.6, "summer_efficiency_pct": 69.9, "comparative_hot_water_efficiency_pct": 51.0, "output_kw_max": 19.0, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["004160", "000041", "0", "2012/Mar/27 10:12", "Boulter Boilers", "Boulter", "Camray", "15/19 External", "", "1997", "2001", "4", "2", "2", "1", "0", "", "", "1", "2", "2", "15", "19", "", "", "81.6", "69.9", "", "51.0", "", "2", "", "", "201", "1", "1", "145", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.3", "81.8", "", "", "", "", "81.7"]} +{"pcdb_id": 4161, "brand_name": "Boulter", "model_name": "Centurion", "model_qualifier": "2.5", "winter_efficiency_pct": 77.5, "summer_efficiency_pct": 67.4, "comparative_hot_water_efficiency_pct": 47.4, "output_kw_max": 22.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["004161", "000041", "0", "2008/Aug/18 09:41", "Boulter Boilers", "Boulter", "Centurion", "2.5", "GC 47 130 03", "1997", "obsolete", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "22", "22", "", "", "77.5", "67.4", "", "47.4", "", "2", "", "", "104", "1", "2", "100", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.5", "76.0", "", "", "", "", "77.1"]} +{"pcdb_id": 4162, "brand_name": "Boulter", "model_name": "Centurion", "model_qualifier": "3.5", "winter_efficiency_pct": 77.8, "summer_efficiency_pct": 68.7, "comparative_hot_water_efficiency_pct": 32.3, "output_kw_max": 22.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 1, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["004162", "000041", "0", "2024/Jan/31 10:17", "Boulter Boilers", "Boulter", "Centurion", "3.5", "GC 47 130 03", "1997", "obsolete", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "22", "22", "", "", "77.8", "68.7", "", "32.3", "", "2", "", "", "106", "1", "2", "100", "0", "1", "1", "0", "40", "0", "15", "2", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.5", "76.0", "", "", "", "", "77.1"]} +{"pcdb_id": 4163, "brand_name": "Maxol", "model_name": "Morocco", "model_qualifier": "20", "winter_efficiency_pct": 72.3, "summer_efficiency_pct": 62.2, "comparative_hot_water_efficiency_pct": 45.5, "output_kw_max": 6.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["004163", "000007", "0", "2012/Mar/27 10:12", "Maxol (Burco Dean Appliances)", "Maxol", "Morocco", "20", "Maxol", "1988", "current", "1", "2", "1", "1", "0", "", "", "1", "2", "1", "6.0", "6.0", "", "", "72.3", "62.2", "", "45.5", "", "2", "", "", "101", "2", "1", "10", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "77.9", "77.9", "", "", "", "", "77.9"]} +{"pcdb_id": 4164, "brand_name": "Maxol", "model_name": "Morocco", "model_qualifier": "30", "winter_efficiency_pct": 72.3, "summer_efficiency_pct": 62.2, "comparative_hot_water_efficiency_pct": 45.5, "output_kw_max": 9.03, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["004164", "000007", "0", "2012/Mar/27 10:12", "Maxol (Burco Dean Appliances)", "Maxol", "Morocco", "30", "Maxol", "1988", "current", "1", "2", "1", "1", "0", "", "", "1", "2", "1", "9.03", "9.03", "", "", "72.3", "62.2", "", "45.5", "", "2", "", "", "101", "2", "1", "10", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "78.0", "77.8", "", "", "", "", "77.9"]} +{"pcdb_id": 4165, "brand_name": "Maxol", "model_name": "Morocco", "model_qualifier": "40", "winter_efficiency_pct": 72.3, "summer_efficiency_pct": 62.2, "comparative_hot_water_efficiency_pct": 45.5, "output_kw_max": 11.7, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["004165", "000007", "0", "2012/Mar/27 10:12", "Maxol (Burco Dean Appliances)", "Maxol", "Morocco", "40", "Maxol", "1988", "current", "1", "2", "1", "1", "0", "", "", "1", "2", "1", "11.7", "11.7", "", "", "72.3", "62.2", "", "45.5", "", "2", "", "", "101", "2", "1", "10", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "78.0", "77.8", "", "", "", "", "77.9"]} +{"pcdb_id": 4166, "brand_name": "Maxol", "model_name": "Microsystem", "model_qualifier": "502RF", "winter_efficiency_pct": 81.4, "summer_efficiency_pct": 71.3, "comparative_hot_water_efficiency_pct": 52.1, "output_kw_max": 14.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["004166", "000007", "0", "2012/Mar/27 10:12", "Maxol (Burco Dean Appliances)", "Maxol", "Microsystem", "502RF", "Maxol", "1999", "current", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "14.6", "14.6", "", "", "81.4", "71.3", "", "52.1", "", "2", "", "", "101", "1", "1", "120", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "83.0", "83.2", "", "", "", "", "83.1"]} +{"pcdb_id": 4167, "brand_name": "Maxol", "model_name": "Microsystem", "model_qualifier": "402RF", "winter_efficiency_pct": 81.4, "summer_efficiency_pct": 71.3, "comparative_hot_water_efficiency_pct": 52.1, "output_kw_max": 11.7, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["004167", "000007", "0", "2012/Mar/27 10:12", "Maxol (Burco Dean Appliances)", "Maxol", "Microsystem", "402RF", "Maxol", "1999", "current", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "11.7", "11.7", "", "", "81.4", "71.3", "", "52.1", "", "2", "", "", "101", "1", "1", "120", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "83.0", "83.2", "", "", "", "", "83.1"]} +{"pcdb_id": 4168, "brand_name": "Maxol", "model_name": "Microsystem", "model_qualifier": "402MDF", "winter_efficiency_pct": 81.4, "summer_efficiency_pct": 71.3, "comparative_hot_water_efficiency_pct": 52.1, "output_kw_max": 11.7, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["004168", "000007", "0", "2012/Mar/27 10:12", "Maxol (Burco Dean Appliances)", "Maxol", "Microsystem", "402MDF", "Maxol", "1999", "current", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "11.7", "11.7", "", "", "81.4", "71.3", "", "52.1", "", "2", "", "", "101", "1", "1", "120", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "83.0", "83.2", "", "", "", "", "83.1"]} +{"pcdb_id": 4169, "brand_name": "Maxol", "model_name": "Microsystem", "model_qualifier": "502MDF", "winter_efficiency_pct": 81.3, "summer_efficiency_pct": 71.2, "comparative_hot_water_efficiency_pct": 52.0, "output_kw_max": 14.74, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["004169", "000007", "0", "2012/Mar/27 10:12", "Maxol (Burco Dean Appliances)", "Maxol", "Microsystem", "502MDF", "Maxol", "1999", "current", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "14.74", "14.74", "", "", "81.3", "71.2", "", "52.0", "", "2", "", "", "101", "1", "1", "120", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.9", "83.0", "", "", "", "", "83.0"]} +{"pcdb_id": 4170, "brand_name": "Maxol", "model_name": "Microturbo", "model_qualifier": "402MDF", "winter_efficiency_pct": 81.5, "summer_efficiency_pct": 71.4, "comparative_hot_water_efficiency_pct": 52.1, "output_kw_max": 11.7, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["004170", "000007", "0", "2012/Mar/27 10:12", "Maxol (Burco Dean Appliances)", "Maxol", "Microturbo", "402MDF", "Maxol", "1992", "current", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "11.7", "11.7", "", "", "81.5", "71.4", "", "52.1", "", "2", "", "", "101", "1", "1", "55", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.7", "83.4", "", "", "", "", "83.3"]} +{"pcdb_id": 4171, "brand_name": "Maxol", "model_name": "Microturbo", "model_qualifier": "402 RF", "winter_efficiency_pct": 81.5, "summer_efficiency_pct": 71.4, "comparative_hot_water_efficiency_pct": 52.1, "output_kw_max": 11.72, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["004171", "000007", "0", "2012/Mar/27 10:12", "Maxol (Burco Dean Appliances)", "Maxol", "Microturbo", "402 RF", "Maxol", "1992", "current", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "11.72", "11.72", "", "", "81.5", "71.4", "", "52.1", "", "2", "", "", "101", "1", "1", "55", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.7", "83.4", "", "", "", "", "83.3"]} +{"pcdb_id": 4172, "brand_name": "Maxol", "model_name": "Microturbo", "model_qualifier": "502MDF", "winter_efficiency_pct": 81.3, "summer_efficiency_pct": 71.2, "comparative_hot_water_efficiency_pct": 52.0, "output_kw_max": 14.74, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["004172", "000007", "0", "2012/Mar/27 10:12", "Maxol (Burco Dean Appliances)", "Maxol", "Microturbo", "502MDF", "Maxol", "1992", "current", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "14.74", "14.74", "", "", "81.3", "71.2", "", "52.0", "", "2", "", "", "101", "1", "1", "55", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.9", "83.0", "", "", "", "", "83.0"]} +{"pcdb_id": 4173, "brand_name": "Maxol", "model_name": "Microturbo", "model_qualifier": "502RF", "winter_efficiency_pct": 81.3, "summer_efficiency_pct": 71.2, "comparative_hot_water_efficiency_pct": 52.0, "output_kw_max": 14.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["004173", "000007", "0", "2012/Mar/27 10:12", "Maxol (Burco Dean Appliances)", "Maxol", "Microturbo", "502RF", "Maxol", "1992", "current", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "14.6", "14.6", "", "", "81.3", "71.2", "", "52.0", "", "2", "", "", "101", "1", "1", "55", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.9", "83.0", "", "", "", "", "83.0"]} +{"pcdb_id": 4181, "brand_name": "Ferroli", "model_name": "100FF", "model_qualifier": "", "winter_efficiency_pct": 71.0, "summer_efficiency_pct": 61.0, "comparative_hot_water_efficiency_pct": 42.8, "output_kw_max": 25.7, "final_year_of_manufacture": 1995, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["004181", "000097", "0", "2010/Sep/13 17:03", "Ferroli", "Ferroli", "100FF", "", "", "1994", "1995", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "25.7", "25.7", "", "", "71.0", "61.0", "", "42.8", "", "3", "", "", "0", "1", "2", "", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 4182, "brand_name": "Ferroli", "model_name": "77CF", "model_qualifier": "", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 39.2, "output_kw_max": 23.3, "final_year_of_manufacture": 1994, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["004182", "000097", "0", "2010/Sep/13 17:03", "Ferroli", "Ferroli", "77CF", "", "", "1989", "1994", "1", "2", "1", "2", "0", "", "", "1", "1", "1", "23.3", "23.3", "", "", "66.0", "56.0", "", "39.2", "", "3", "", "", "0", "2", "2", "", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 4183, "brand_name": "Ferroli", "model_name": "77FF(P)", "model_qualifier": "", "winter_efficiency_pct": 71.0, "summer_efficiency_pct": 61.0, "comparative_hot_water_efficiency_pct": 42.8, "output_kw_max": 22.3, "final_year_of_manufacture": 1994, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["004183", "000097", "0", "2010/Sep/13 17:03", "Ferroli", "Ferroli", "77FF(P)", "", "", "1989", "1994", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "22.3", "22.3", "", "", "71.0", "61.0", "", "42.8", "", "3", "", "", "0", "2", "2", "150", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 4184, "brand_name": "Ferroli", "model_name": "77FF", "model_qualifier": "", "winter_efficiency_pct": 71.0, "summer_efficiency_pct": 61.0, "comparative_hot_water_efficiency_pct": 42.8, "output_kw_max": 22.3, "final_year_of_manufacture": 1994, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["004184", "000097", "0", "2010/Sep/13 17:03", "Ferroli", "Ferroli", "77FF", "", "", "1989", "1994", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "22.3", "22.3", "", "", "71.0", "61.0", "", "42.8", "", "3", "", "", "0", "2", "2", "150", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 4185, "brand_name": "Ferroli", "model_name": "Optima 1000", "model_qualifier": "", "winter_efficiency_pct": 71.0, "summer_efficiency_pct": 61.0, "comparative_hot_water_efficiency_pct": 42.8, "output_kw_max": 27.9, "final_year_of_manufacture": 1995, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["004185", "000097", "0", "2010/Sep/13 17:03", "Ferroli", "Ferroli", "Optima 1000", "", "", "1994", "1995", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "27.9", "27.9", "", "", "71.0", "61.0", "", "42.8", "", "3", "", "", "0", "1", "2", "150", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 4186, "brand_name": "Ferroli", "model_name": "Optima 200", "model_qualifier": "", "winter_efficiency_pct": 75.1, "summer_efficiency_pct": 65.0, "comparative_hot_water_efficiency_pct": 45.7, "output_kw_max": 23.3, "final_year_of_manufacture": 1995, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["004186", "000097", "0", "2006/Jan/17 12:55", "Ferroli", "Ferroli", "Optima 200", "", "", "1994", "1995", "1", "2", "1", "2", "0", "", "", "1", "1", "1", "23.3", "23.3", "", "", "75.1", "65.0", "", "45.7", "", "2", "", "", "104", "2", "2", "", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.5", "79.1", "", "", "", "", "79.6"]} +{"pcdb_id": 4187, "brand_name": "Ferroli", "model_name": "Optima 2000", "model_qualifier": "", "winter_efficiency_pct": 92.0, "summer_efficiency_pct": 74.0, "comparative_hot_water_efficiency_pct": 51.9, "output_kw_max": 24.2, "final_year_of_manufacture": 1995, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["004187", "000097", "0", "2010/Sep/13 17:03", "Ferroli", "Ferroli", "Optima 2000", "", "", "1994", "1995", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "92.0", "74.0", "", "51.9", "", "3", "", "", "0", "1", "2", "150", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 4188, "brand_name": "Ferroli", "model_name": "Optima 600", "model_qualifier": "", "winter_efficiency_pct": 71.0, "summer_efficiency_pct": 61.0, "comparative_hot_water_efficiency_pct": 42.8, "output_kw_max": 22.3, "final_year_of_manufacture": 1995, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["004188", "000097", "0", "2010/Sep/13 17:03", "Ferroli", "Ferroli", "Optima 600", "", "", "1994", "1995", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "22.3", "22.3", "", "", "71.0", "61.0", "", "42.8", "", "3", "", "", "0", "2", "2", "150", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 4189, "brand_name": "Ferroli", "model_name": "Optima 700", "model_qualifier": "", "winter_efficiency_pct": 71.0, "summer_efficiency_pct": 61.0, "comparative_hot_water_efficiency_pct": 42.8, "output_kw_max": 22.3, "final_year_of_manufacture": 1995, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["004189", "000097", "0", "2010/Sep/13 17:03", "Ferroli", "Ferroli", "Optima 700", "", "", "1994", "1995", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "22.3", "22.3", "", "", "71.0", "61.0", "", "42.8", "", "3", "", "", "0", "2", "2", "150", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 4190, "brand_name": "Ferroli", "model_name": "Optima 800", "model_qualifier": "", "winter_efficiency_pct": 71.0, "summer_efficiency_pct": 61.0, "comparative_hot_water_efficiency_pct": 42.8, "output_kw_max": 22.3, "final_year_of_manufacture": 1995, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["004190", "000097", "0", "2010/Sep/13 17:03", "Ferroli", "Ferroli", "Optima 800", "", "", "1994", "1995", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "22.3", "22.3", "", "", "71.0", "61.0", "", "42.8", "", "3", "", "", "0", "1", "2", "150", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 4191, "brand_name": "Ferroli", "model_name": "Optima 900", "model_qualifier": "", "winter_efficiency_pct": 71.0, "summer_efficiency_pct": 61.0, "comparative_hot_water_efficiency_pct": 42.8, "output_kw_max": 27.9, "final_year_of_manufacture": 1995, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["004191", "000097", "0", "2010/Sep/13 17:03", "Ferroli", "Ferroli", "Optima 900", "", "", "1994", "1995", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "27.9", "27.9", "", "", "71.0", "61.0", "", "42.8", "", "3", "", "", "0", "2", "2", "150", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 5890, "brand_name": "Ideal", "model_name": "Mexico Super", "model_qualifier": "40FF", "winter_efficiency_pct": 77.6, "summer_efficiency_pct": 67.5, "comparative_hot_water_efficiency_pct": 49.3, "output_kw_max": 11.7, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["005890", "000008", "0", "2018/Oct/15 12:00", "Caradon Plumbing", "Ideal", "Mexico Super", "40FF", "G.C.No 41 349 78", "", "2001", "1", "1", "1", "1", "0", "", "", "1", "2", "2", "8.8", "11.7", "", "", "77.6", "67.5", "", "49.3", "", "2", "", "", "101", "1", "1", "100", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.4", "78.9", "", "", "", "", "79.0"]} +{"pcdb_id": 5891, "brand_name": "Ideal", "model_name": "Mexico Super", "model_qualifier": "50FF", "winter_efficiency_pct": 77.6, "summer_efficiency_pct": 67.5, "comparative_hot_water_efficiency_pct": 49.3, "output_kw_max": 14.7, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["005891", "000008", "0", "2018/Oct/15 12:00", "Caradon Plumbing", "Ideal", "Mexico Super", "50FF", "G.C.No 41 349 79", "", "2001", "1", "1", "1", "1", "0", "", "", "1", "2", "2", "11.7", "14.7", "", "", "77.6", "67.5", "", "49.3", "", "2", "", "", "101", "1", "1", "100", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.7", "78.7", "", "", "", "", "78.9"]} +{"pcdb_id": 5892, "brand_name": "Ideal", "model_name": "Mexico Super", "model_qualifier": "60FF", "winter_efficiency_pct": 78.0, "summer_efficiency_pct": 67.9, "comparative_hot_water_efficiency_pct": 49.6, "output_kw_max": 17.6, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["005892", "000008", "0", "2018/Oct/15 12:00", "Caradon Plumbing", "Ideal", "Mexico Super", "60FF", "G.C.No 41 349 80", "", "2001", "1", "1", "1", "1", "0", "", "", "1", "2", "2", "14.7", "17.6", "", "", "78.0", "67.9", "", "49.6", "", "2", "", "", "101", "1", "1", "100", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "80.1", "79.1", "", "", "", "", "79.3"]} +{"pcdb_id": 5893, "brand_name": "Ideal", "model_name": "Mexico Super", "model_qualifier": "70FF", "winter_efficiency_pct": 78.5, "summer_efficiency_pct": 68.4, "comparative_hot_water_efficiency_pct": 50.0, "output_kw_max": 20.5, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["005893", "000008", "0", "2018/Oct/15 12:00", "Caradon Plumbing", "Ideal", "Mexico Super", "70FF", "G.C.No 41 349 81", "", "2001", "1", "1", "1", "1", "0", "", "", "1", "2", "2", "17.6", "20.5", "", "", "78.5", "68.4", "", "50.0", "", "2", "", "", "101", "1", "1", "100", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.8", "80.4", "", "", "", "", "80.3"]} +{"pcdb_id": 5894, "brand_name": "Ideal", "model_name": "Mexico Super", "model_qualifier": "80FF", "winter_efficiency_pct": 80.6, "summer_efficiency_pct": 70.5, "comparative_hot_water_efficiency_pct": 51.5, "output_kw_max": 23.4, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["005894", "000008", "0", "2018/Oct/15 12:00", "Caradon Plumbing", "Ideal", "Mexico Super", "80FF", "G.C.No 41 349 82", "", "2001", "1", "1", "1", "1", "0", "", "", "1", "2", "2", "20.5", "23.4", "", "", "80.6", "70.5", "", "51.5", "", "2", "", "", "101", "1", "1", "100", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.9", "82.4", "", "", "", "", "82.3"]} +{"pcdb_id": 5895, "brand_name": "Ideal", "model_name": "Mexico Super", "model_qualifier": "100FF", "winter_efficiency_pct": 78.5, "summer_efficiency_pct": 68.4, "comparative_hot_water_efficiency_pct": 50.0, "output_kw_max": 29.3, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["005895", "000008", "0", "2018/Oct/15 12:00", "Caradon Plumbing", "Ideal", "Mexico Super", "100FF", "G.C.No 41 349 83", "", "2001", "1", "1", "1", "1", "0", "", "", "1", "2", "2", "23.4", "29.3", "", "", "78.5", "68.4", "", "50.0", "", "2", "", "", "101", "1", "1", "100", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "80.6", "79.6", "", "", "", "", "79.8"]} +{"pcdb_id": 5896, "brand_name": "Ideal", "model_name": "Mexico Super", "model_qualifier": "125FF", "winter_efficiency_pct": 78.8, "summer_efficiency_pct": 68.7, "comparative_hot_water_efficiency_pct": 50.2, "output_kw_max": 36.6, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["005896", "000008", "0", "2018/Oct/15 12:00", "Caradon Plumbing", "Ideal", "Mexico Super", "125FF", "G.C.No 41 349 84", "", "2001", "1", "1", "1", "1", "0", "", "", "1", "2", "2", "29.3", "36.6", "", "", "78.8", "68.7", "", "50.2", "", "2", "", "", "101", "1", "1", "100", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "80.5", "80.3", "", "", "", "", "80.3"]} +{"pcdb_id": 5897, "brand_name": "Ideal", "model_name": "C", "model_qualifier": "95FF", "winter_efficiency_pct": 79.4, "summer_efficiency_pct": 69.3, "comparative_hot_water_efficiency_pct": 48.7, "output_kw_max": 27.9, "final_year_of_manufacture": 2002, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["005897", "000008", "0", "2018/Oct/15 12:00", "Caradon Plumbing", "Ideal", "C", "95FF", "G.C.No 47 348 06", "", "2002", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "27.9", "27.9", "", "", "79.4", "69.3", "", "48.7", "", "2", "", "", "104", "1", "2", "120", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.0", "79.2", "", "", "", "", "79.7"]} +{"pcdb_id": 5898, "brand_name": "Ideal", "model_name": "C", "model_qualifier": "80FF", "winter_efficiency_pct": 79.3, "summer_efficiency_pct": 69.2, "comparative_hot_water_efficiency_pct": 48.7, "output_kw_max": 23.26, "final_year_of_manufacture": 2002, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["005898", "000008", "0", "2018/Oct/15 12:00", "Caradon Plumbing", "Ideal", "C", "80FF", "G.C.No 47 348 05", "", "2002", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "23.26", "23.26", "", "", "79.3", "69.2", "", "48.7", "", "2", "", "", "104", "1", "2", "120", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.1", "79.0", "", "", "", "", "79.6"]} +{"pcdb_id": 5899, "brand_name": "Ideal", "model_name": "Maximiser", "model_qualifier": "SE 65", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 55.1, "final_year_of_manufacture": 2002, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["005899", "000008", "0", "2018/Oct/15 12:00", "Caradon Plumbing", "Ideal", "Maximiser", "SE 65", "152813", "", "2002", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "55.1", "55.1", "", "", "88.1", "79.1", "", "57.8", "", "2", "", "", "102", "1", "2", "180", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "97.1", "", "", "", "", "95.4"]} +{"pcdb_id": 5900, "brand_name": "Ideal", "model_name": "Maximiser", "model_qualifier": "SE 42", "winter_efficiency_pct": 87.8, "summer_efficiency_pct": 78.8, "comparative_hot_water_efficiency_pct": 57.6, "output_kw_max": 40.0, "final_year_of_manufacture": 2002, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["005900", "000008", "0", "2018/Oct/15 12:00", "Caradon Plumbing", "Ideal", "Maximiser", "SE 42", "152393", "", "2002", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "40", "40", "", "", "87.8", "78.8", "", "57.6", "", "2", "", "", "102", "1", "2", "180", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.7", "96.0", "", "", "", "", "94.6"]} +{"pcdb_id": 5901, "brand_name": "Ideal", "model_name": "Concord", "model_qualifier": "CX40", "winter_efficiency_pct": 72.9, "summer_efficiency_pct": 62.8, "comparative_hot_water_efficiency_pct": 45.9, "output_kw_max": 42.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["005901", "000008", "0", "2012/Mar/27 10:12", "Caradon Plumbing", "Ideal", "Concord", "CX40", "P.I.No 87/AP/80", "", "current", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "42", "42", "", "", "72.9", "62.8", "", "45.9", "", "2", "", "", "101", "2", "1", "5", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.2", "77.8", "", "", "", "", "78.1"]} +{"pcdb_id": 5902, "brand_name": "Ideal", "model_name": "Mexico Super", "model_qualifier": "CF3/40", "winter_efficiency_pct": 72.7, "summer_efficiency_pct": 62.6, "comparative_hot_water_efficiency_pct": 45.7, "output_kw_max": 11.7, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["005902", "000008", "0", "2018/Oct/15 12:00", "Caradon Plumbing", "Ideal", "Mexico Super", "CF3/40", "G.C.No 41 348 10", "", "2001", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "8.8", "11.7", "", "", "72.7", "62.6", "", "45.7", "", "2", "", "", "101", "2", "1", "5", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "78.8", "77.7", "", "", "", "", "77.9"]} +{"pcdb_id": 5903, "brand_name": "Ideal", "model_name": "Mexico Super", "model_qualifier": "CF3/50", "winter_efficiency_pct": 72.2, "summer_efficiency_pct": 62.1, "comparative_hot_water_efficiency_pct": 45.4, "output_kw_max": 14.7, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["005903", "000008", "0", "2018/Oct/15 12:00", "Caradon Plumbing", "Ideal", "Mexico Super", "CF3/50", "G.C.No 41 348 12", "", "2001", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "11.7", "14.7", "", "", "72.2", "62.1", "", "45.4", "", "2", "", "", "101", "2", "1", "5", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.1", "76.5", "", "", "", "", "77.0"]} +{"pcdb_id": 5904, "brand_name": "Ideal", "model_name": "Mexico Super", "model_qualifier": "CF3/60", "winter_efficiency_pct": 72.7, "summer_efficiency_pct": 62.6, "comparative_hot_water_efficiency_pct": 45.8, "output_kw_max": 17.6, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["005904", "000008", "0", "2018/Oct/15 12:00", "Caradon Plumbing", "Ideal", "Mexico Super", "CF3/60", "G.C.No 41 348 13", "", "2001", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "14.7", "17.6", "", "", "72.7", "62.6", "", "45.8", "", "2", "", "", "101", "2", "1", "5", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.0", "77.7", "", "", "", "", "77.9"]} +{"pcdb_id": 5905, "brand_name": "Ideal", "model_name": "Mexico Slimline", "model_qualifier": "RS3/50", "winter_efficiency_pct": 73.8, "summer_efficiency_pct": 63.7, "comparative_hot_water_efficiency_pct": 46.5, "output_kw_max": 14.7, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["005905", "000008", "0", "2018/Oct/15 12:00", "Caradon Plumbing", "Ideal", "Mexico Slimline", "RS3/50", "G.C.No 41 348 06", "", "2001", "1", "1", "1", "1", "0", "", "", "1", "2", "1", "11.7", "14.7", "", "", "73.8", "63.7", "", "46.5", "", "2", "", "", "101", "2", "1", "5", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.0", "79.8", "", "", "", "", "79.7"]} +{"pcdb_id": 5906, "brand_name": "Ideal", "model_name": "Mexico Super", "model_qualifier": "CF3/100", "winter_efficiency_pct": 72.5, "summer_efficiency_pct": 62.4, "comparative_hot_water_efficiency_pct": 45.6, "output_kw_max": 29.3, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["005906", "000008", "0", "2018/Oct/15 12:00", "Caradon Plumbing", "Ideal", "Mexico Super", "CF3/100", "G.C.No 41 348 18", "", "2001", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "23.4", "29.3", "", "", "72.5", "62.4", "", "45.6", "", "2", "", "", "101", "2", "1", "5", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.1", "77.0", "", "", "", "", "77.4"]} +{"pcdb_id": 5907, "brand_name": "Ideal", "model_name": "Mexico Super", "model_qualifier": "CF3/125", "winter_efficiency_pct": 72.7, "summer_efficiency_pct": 62.6, "comparative_hot_water_efficiency_pct": 45.8, "output_kw_max": 36.6, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["005907", "000008", "0", "2018/Oct/15 12:00", "Caradon Plumbing", "Ideal", "Mexico Super", "CF3/125", "G.C.No 41 348 20", "", "2001", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "29.3", "36.6", "", "", "72.7", "62.6", "", "45.8", "", "2", "", "", "101", "2", "1", "5", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.6", "77.1", "", "", "", "", "77.6"]} +{"pcdb_id": 5908, "brand_name": "Ideal", "model_name": "Mexico Super", "model_qualifier": "CF3/140", "winter_efficiency_pct": 73.6, "summer_efficiency_pct": 63.5, "comparative_hot_water_efficiency_pct": 46.3, "output_kw_max": 41.0, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["005908", "000008", "0", "2018/Oct/15 12:00", "Caradon Plumbing", "Ideal", "Mexico Super", "CF3/140", "G.C.No 41 348 21", "", "2001", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "36.6", "41.0", "", "", "73.6", "63.5", "", "46.3", "", "2", "", "", "101", "2", "1", "5", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.0", "79.3", "", "", "", "", "79.2"]} +{"pcdb_id": 5909, "brand_name": "Ideal", "model_name": "Classic", "model_qualifier": "RS 245P", "winter_efficiency_pct": 74.8, "summer_efficiency_pct": 64.7, "comparative_hot_water_efficiency_pct": 47.3, "output_kw_max": 13.2, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["005909", "000008", "0", "2018/Oct/15 12:00", "Caradon Plumbing", "Ideal", "Classic", "RS 245P", "G.C.41 387 14", "", "2001", "2", "2", "1", "1", "0", "", "", "1", "2", "1", "13.2", "13.2", "", "", "74.8", "64.7", "", "47.3", "", "2", "0", "", "101", "2", "1", "5", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.1", "79.8", "", "", "", "", "80.0"]} +{"pcdb_id": 5910, "brand_name": "Ideal", "model_name": "Classic", "model_qualifier": "RS 255P", "winter_efficiency_pct": 73.7, "summer_efficiency_pct": 63.6, "comparative_hot_water_efficiency_pct": 46.5, "output_kw_max": 16.1, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["005910", "000008", "0", "2018/Oct/15 12:00", "Caradon Plumbing", "Ideal", "Classic", "RS 255P", "G.C.41 387 15", "", "2001", "2", "2", "1", "1", "0", "", "", "1", "2", "1", "16.1", "16.1", "", "", "73.7", "63.6", "", "46.5", "", "2", "0", "", "101", "2", "1", "5", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.7", "79.0", "", "", "", "", "79.1"]} +{"pcdb_id": 5911, "brand_name": "Ideal", "model_name": "Classic", "model_qualifier": "LX RS245P", "winter_efficiency_pct": 74.8, "summer_efficiency_pct": 64.7, "comparative_hot_water_efficiency_pct": 47.3, "output_kw_max": 13.2, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["005911", "000008", "0", "2018/Oct/15 12:00", "Caradon Plumbing", "Ideal", "Classic", "LX RS245P", "G.C.41 387 37", "", "2001", "2", "2", "1", "1", "0", "", "", "1", "2", "1", "13.2", "13.2", "", "", "74.8", "64.7", "", "47.3", "", "2", "0", "", "101", "2", "1", "5", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.1", "79.8", "", "", "", "", "80.0"]} +{"pcdb_id": 5912, "brand_name": "Ideal", "model_name": "Classic", "model_qualifier": "LX RS255P", "winter_efficiency_pct": 73.7, "summer_efficiency_pct": 63.6, "comparative_hot_water_efficiency_pct": 46.5, "output_kw_max": 16.1, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["005912", "000008", "0", "2018/Oct/15 12:00", "Caradon Plumbing", "Ideal", "Classic", "LX RS255P", "G.C.41 387 38", "", "2001", "2", "2", "1", "1", "0", "", "", "1", "2", "1", "16.1", "16.1", "", "", "73.7", "63.6", "", "46.5", "", "2", "0", "", "101", "2", "1", "5", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.7", "79.0", "", "", "", "", "79.1"]} +{"pcdb_id": 5913, "brand_name": "Ideal", "model_name": "Classic", "model_qualifier": "FF250P", "winter_efficiency_pct": 82.6, "summer_efficiency_pct": 72.5, "comparative_hot_water_efficiency_pct": 52.9, "output_kw_max": 14.7, "final_year_of_manufacture": 2004, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["005913", "000008", "0", "2018/Oct/15 12:00", "Caradon Plumbing", "Ideal", "Classic", "FF250P", "G.C.41 387 07", "", "2004", "2", "2", "1", "1", "0", "", "", "1", "2", "2", "14.7", "14.7", "", "", "82.6", "72.5", "", "52.9", "", "2", "0", "", "101", "1", "1", "100", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "84.5", "84.2", "", "", "", "", "84.2"]} +{"pcdb_id": 5914, "brand_name": "Ideal", "model_name": "Classic", "model_qualifier": "FF260P", "winter_efficiency_pct": 79.4, "summer_efficiency_pct": 69.3, "comparative_hot_water_efficiency_pct": 50.7, "output_kw_max": 16.7, "final_year_of_manufacture": 2004, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["005914", "000008", "0", "2018/Oct/15 12:00", "Caradon Plumbing", "Ideal", "Classic", "FF260P", "G.C.41 387 08", "", "2004", "2", "2", "1", "1", "0", "", "", "1", "2", "2", "16.7", "16.7", "", "", "79.4", "69.3", "", "50.7", "", "2", "0", "", "101", "1", "1", "100", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.0", "81.0", "", "", "", "", "81.0"]} +{"pcdb_id": 5915, "brand_name": "Ideal", "model_name": "Classic", "model_qualifier": "FF275P", "winter_efficiency_pct": 78.3, "summer_efficiency_pct": 68.2, "comparative_hot_water_efficiency_pct": 49.8, "output_kw_max": 21.4, "final_year_of_manufacture": 2004, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["005915", "000008", "0", "2018/Oct/15 12:00", "Caradon Plumbing", "Ideal", "Classic", "FF275P", "G.C.41 387 09", "", "2004", "2", "2", "1", "1", "0", "", "", "1", "2", "2", "21.4", "21.4", "", "", "78.3", "68.2", "", "49.8", "", "2", "0", "", "101", "1", "1", "100", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.9", "79.9", "", "", "", "", "79.9"]} +{"pcdb_id": 5916, "brand_name": "Ideal", "model_name": "Classic", "model_qualifier": "LX FF250P", "winter_efficiency_pct": 82.6, "summer_efficiency_pct": 72.5, "comparative_hot_water_efficiency_pct": 52.9, "output_kw_max": 14.7, "final_year_of_manufacture": 2004, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["005916", "000008", "0", "2018/Oct/15 12:00", "Caradon Plumbing", "Ideal", "Classic", "LX FF250P", "G.C.41 387 30", "", "2004", "2", "2", "1", "1", "0", "", "", "1", "2", "2", "14.7", "14.7", "", "", "82.6", "72.5", "", "52.9", "", "2", "0", "", "101", "1", "1", "100", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "84.5", "84.2", "", "", "", "", "84.2"]} +{"pcdb_id": 5917, "brand_name": "Ideal", "model_name": "Classic", "model_qualifier": "LX FF260P", "winter_efficiency_pct": 79.4, "summer_efficiency_pct": 69.3, "comparative_hot_water_efficiency_pct": 50.7, "output_kw_max": 16.7, "final_year_of_manufacture": 2004, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["005917", "000008", "0", "2018/Oct/15 12:00", "Caradon Plumbing", "Ideal", "Classic", "LX FF260P", "G.C.41 387 31", "", "2004", "2", "2", "1", "1", "0", "", "", "1", "2", "2", "16.7", "16.7", "", "", "79.4", "69.3", "", "50.7", "", "2", "0", "", "101", "1", "1", "100", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.0", "81.0", "", "", "", "", "81.0"]} +{"pcdb_id": 5918, "brand_name": "Ideal", "model_name": "Classic", "model_qualifier": "LX FF275P", "winter_efficiency_pct": 78.3, "summer_efficiency_pct": 68.2, "comparative_hot_water_efficiency_pct": 49.8, "output_kw_max": 21.4, "final_year_of_manufacture": 2004, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["005918", "000008", "0", "2018/Oct/15 12:00", "Caradon Plumbing", "Ideal", "Classic", "LX FF275P", "G.C.41 387 32", "", "2004", "2", "2", "1", "1", "0", "", "", "1", "2", "2", "21.4", "21.4", "", "", "78.3", "68.2", "", "49.8", "", "2", "0", "", "101", "1", "1", "100", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.9", "79.9", "", "", "", "", "79.9"]} +{"pcdb_id": 5919, "brand_name": "Ideal", "model_name": "Classic", "model_qualifier": "RS 230", "winter_efficiency_pct": 72.1, "summer_efficiency_pct": 62.0, "comparative_hot_water_efficiency_pct": 45.3, "output_kw_max": 8.8, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["005919", "000008", "0", "2018/Oct/15 12:00", "Caradon Plumbing", "Ideal", "Classic", "RS 230", "G.C.41 387 10", "", "2001", "1", "2", "1", "1", "0", "", "", "1", "2", "1", "4.4", "8.8", "", "", "72.1", "62.0", "", "45.3", "", "2", "", "", "101", "2", "1", "5", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.7", "75.6", "", "", "", "", "76.4"]} +{"pcdb_id": 5920, "brand_name": "Ideal", "model_name": "Classic", "model_qualifier": "RS 240", "winter_efficiency_pct": 74.1, "summer_efficiency_pct": 64.0, "comparative_hot_water_efficiency_pct": 46.7, "output_kw_max": 11.7, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["005920", "000008", "0", "2018/Oct/15 12:00", "Caradon Plumbing", "Ideal", "Classic", "RS 240", "G.C.41 387 11", "", "2001", "1", "2", "1", "1", "0", "", "", "1", "2", "1", "8.8", "11.7", "", "", "74.1", "64.0", "", "46.7", "", "2", "", "", "101", "2", "1", "5", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "80.4", "79.0", "", "", "", "", "79.3"]} +{"pcdb_id": 5921, "brand_name": "Ideal", "model_name": "Classic", "model_qualifier": "RS 250", "winter_efficiency_pct": 73.2, "summer_efficiency_pct": 63.1, "comparative_hot_water_efficiency_pct": 46.1, "output_kw_max": 14.7, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["005921", "000008", "0", "2018/Oct/15 12:00", "Caradon Plumbing", "Ideal", "Classic", "RS 250", "G.C.41 387 12", "", "2001", "1", "2", "1", "1", "0", "", "", "1", "2", "1", "11.7", "14.7", "", "", "73.2", "63.1", "", "46.1", "", "2", "", "", "101", "2", "1", "5", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.8", "77.8", "", "", "", "", "78.2"]} +{"pcdb_id": 5922, "brand_name": "Ideal", "model_name": "Classic", "model_qualifier": "RS 260", "winter_efficiency_pct": 73.2, "summer_efficiency_pct": 63.1, "comparative_hot_water_efficiency_pct": 46.1, "output_kw_max": 17.6, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["005922", "000008", "0", "2018/Oct/15 12:00", "Caradon Plumbing", "Ideal", "Classic", "RS 260", "G.C.41 387 13", "", "2001", "1", "2", "1", "1", "0", "", "", "1", "2", "1", "14.7", "17.6", "", "", "73.2", "63.1", "", "46.1", "", "2", "", "", "101", "2", "1", "5", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.4", "78.3", "", "", "", "", "78.5"]} +{"pcdb_id": 5923, "brand_name": "Ideal", "model_name": "Classic", "model_qualifier": "LX RS230", "winter_efficiency_pct": 72.1, "summer_efficiency_pct": 62.0, "comparative_hot_water_efficiency_pct": 45.3, "output_kw_max": 8.8, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["005923", "000008", "0", "2018/Oct/15 12:00", "Caradon Plumbing", "Ideal", "Classic", "LX RS230", "G.C.41 387 33", "", "2001", "1", "2", "1", "1", "0", "", "", "1", "2", "1", "4.4", "8.8", "", "", "72.1", "62.0", "", "45.3", "", "2", "", "", "101", "2", "1", "5", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.7", "75.6", "", "", "", "", "76.4"]} +{"pcdb_id": 5924, "brand_name": "Ideal", "model_name": "Classic", "model_qualifier": "LX RS240", "winter_efficiency_pct": 74.1, "summer_efficiency_pct": 64.0, "comparative_hot_water_efficiency_pct": 46.7, "output_kw_max": 11.7, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["005924", "000008", "0", "2018/Oct/15 12:00", "Caradon Plumbing", "Ideal", "Classic", "LX RS240", "G.C.41 387 34", "", "2001", "1", "2", "1", "1", "0", "", "", "1", "2", "1", "8.8", "11.7", "", "", "74.1", "64.0", "", "46.7", "", "2", "", "", "101", "2", "1", "5", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "80.4", "79.0", "", "", "", "", "79.3"]} +{"pcdb_id": 5925, "brand_name": "Ideal", "model_name": "Classic", "model_qualifier": "LX RS250", "winter_efficiency_pct": 73.2, "summer_efficiency_pct": 63.1, "comparative_hot_water_efficiency_pct": 46.1, "output_kw_max": 14.7, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["005925", "000008", "0", "2018/Oct/15 12:00", "Caradon Plumbing", "Ideal", "Classic", "LX RS250", "G.C.41 387 35", "", "2001", "1", "2", "1", "1", "0", "", "", "1", "2", "1", "11.7", "14.7", "", "", "73.2", "63.1", "", "46.1", "", "2", "", "", "101", "2", "1", "5", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.8", "77.8", "", "", "", "", "78.2"]} +{"pcdb_id": 5926, "brand_name": "Ideal", "model_name": "Classic", "model_qualifier": "LX RS260", "winter_efficiency_pct": 73.2, "summer_efficiency_pct": 63.1, "comparative_hot_water_efficiency_pct": 46.1, "output_kw_max": 17.6, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["005926", "000008", "0", "2018/Oct/15 12:00", "Caradon Plumbing", "Ideal", "Classic", "LX RS260", "G.C.41 387 36", "", "2001", "1", "2", "1", "1", "0", "", "", "1", "2", "1", "14.7", "17.6", "", "", "73.2", "63.1", "", "46.1", "", "2", "", "", "101", "2", "1", "5", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.4", "78.3", "", "", "", "", "78.5"]} +{"pcdb_id": 5927, "brand_name": "Ideal", "model_name": "Classic", "model_qualifier": "FF230", "winter_efficiency_pct": 78.1, "summer_efficiency_pct": 68.0, "comparative_hot_water_efficiency_pct": 49.7, "output_kw_max": 8.8, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["005927", "000008", "0", "2018/Oct/15 12:00", "Caradon Plumbing", "Ideal", "Classic", "FF230", "G.C.41 387 01", "", "2001", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "4.4", "8.8", "", "", "78.1", "68.0", "", "49.7", "", "2", "", "", "101", "1", "1", "100", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.6", "77.8", "", "", "", "", "78.6"]} +{"pcdb_id": 5928, "brand_name": "Ideal", "model_name": "Classic", "model_qualifier": "FF240", "winter_efficiency_pct": 77.1, "summer_efficiency_pct": 67.0, "comparative_hot_water_efficiency_pct": 48.9, "output_kw_max": 11.7, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["005928", "000008", "0", "2018/Oct/15 12:00", "Caradon Plumbing", "Ideal", "Classic", "FF240", "G.C.41 387 02", "", "2001", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "8.8", "11.7", "", "", "77.1", "67.0", "", "48.9", "", "2", "", "", "101", "1", "1", "100", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.3", "78.0", "", "", "", "", "78.3"]} +{"pcdb_id": 5929, "brand_name": "Ideal", "model_name": "Classic", "model_qualifier": "FF250", "winter_efficiency_pct": 77.6, "summer_efficiency_pct": 67.5, "comparative_hot_water_efficiency_pct": 49.3, "output_kw_max": 14.7, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["005929", "000008", "0", "2018/Oct/15 12:00", "Caradon Plumbing", "Ideal", "Classic", "FF250", "G.C.41 387 03", "", "2001", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "11.7", "14.7", "", "", "77.6", "67.5", "", "49.3", "", "2", "", "", "101", "1", "1", "100", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "80.0", "78.5", "", "", "", "", "78.8"]} +{"pcdb_id": 5930, "brand_name": "Ideal", "model_name": "Classic", "model_qualifier": "FF260", "winter_efficiency_pct": 77.8, "summer_efficiency_pct": 67.7, "comparative_hot_water_efficiency_pct": 49.4, "output_kw_max": 17.6, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["005930", "000008", "0", "2018/Oct/15 12:00", "Caradon Plumbing", "Ideal", "Classic", "FF260", "G.C.41 387 04", "", "2001", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "14.7", "17.6", "", "", "77.8", "67.7", "", "49.4", "", "2", "", "", "101", "1", "1", "100", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.8", "78.9", "", "", "", "", "79.1"]} +{"pcdb_id": 5931, "brand_name": "Ideal", "model_name": "Classic", "model_qualifier": "FF270", "winter_efficiency_pct": 78.1, "summer_efficiency_pct": 68.0, "comparative_hot_water_efficiency_pct": 49.7, "output_kw_max": 20.5, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["005931", "000008", "0", "2018/Oct/15 12:00", "Caradon Plumbing", "Ideal", "Classic", "FF270", "G.C.41 387 05", "", "2001", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "17.6", "20.5", "", "", "78.1", "68.0", "", "49.7", "", "2", "", "", "101", "1", "1", "100", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.6", "79.7", "", "", "", "", "79.7"]} +{"pcdb_id": 5932, "brand_name": "Ideal", "model_name": "Classic", "model_qualifier": "FF280", "winter_efficiency_pct": 77.0, "summer_efficiency_pct": 66.9, "comparative_hot_water_efficiency_pct": 48.8, "output_kw_max": 23.4, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["005932", "000008", "0", "2018/Oct/15 12:00", "Caradon Plumbing", "Ideal", "Classic", "FF280", "G.C.41 387 06", "", "2001", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "20.5", "23.4", "", "", "77.0", "66.9", "", "48.8", "", "2", "", "", "101", "1", "1", "100", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "78.7", "78.5", "", "", "", "", "78.5"]} +{"pcdb_id": 5933, "brand_name": "Ideal", "model_name": "Classic", "model_qualifier": "FF2100", "winter_efficiency_pct": 77.6, "summer_efficiency_pct": 67.5, "comparative_hot_water_efficiency_pct": 49.3, "output_kw_max": 29.3, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["005933", "000008", "0", "2018/Oct/15 12:00", "Caradon Plumbing", "Ideal", "Classic", "FF2100", "G.C.41 349 71", "", "2001", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "24.9", "29.3", "", "", "77.6", "67.5", "", "49.3", "", "2", "", "", "101", "1", "1", "100", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.9", "78.6", "", "", "", "", "78.8"]} +{"pcdb_id": 5934, "brand_name": "Ideal", "model_name": "Classic", "model_qualifier": "LX FF230", "winter_efficiency_pct": 78.1, "summer_efficiency_pct": 68.0, "comparative_hot_water_efficiency_pct": 49.7, "output_kw_max": 8.8, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["005934", "000008", "0", "2018/Oct/15 12:00", "Caradon Plumbing", "Ideal", "Classic", "LX FF230", "G.C.41 387 24", "", "2001", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "4.4", "8.8", "", "", "78.1", "68.0", "", "49.7", "", "2", "", "", "101", "1", "1", "100", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.6", "77.8", "", "", "", "", "78.6"]} +{"pcdb_id": 5935, "brand_name": "Ideal", "model_name": "Classic", "model_qualifier": "LX FF240", "winter_efficiency_pct": 77.1, "summer_efficiency_pct": 67.0, "comparative_hot_water_efficiency_pct": 48.9, "output_kw_max": 11.7, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["005935", "000008", "0", "2018/Oct/15 12:00", "Caradon Plumbing", "Ideal", "Classic", "LX FF240", "G.C.41 387 25", "", "2001", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "8.8", "11.7", "", "", "77.1", "67.0", "", "48.9", "", "2", "", "", "101", "1", "1", "100", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.3", "78.0", "", "", "", "", "78.3"]} +{"pcdb_id": 5936, "brand_name": "Ideal", "model_name": "Classic", "model_qualifier": "LX FF250", "winter_efficiency_pct": 77.6, "summer_efficiency_pct": 67.5, "comparative_hot_water_efficiency_pct": 49.3, "output_kw_max": 14.7, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["005936", "000008", "0", "2018/Oct/15 12:00", "Caradon Plumbing", "Ideal", "Classic", "LX FF250", "G.C.41 387 26", "", "2001", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "11.7", "14.7", "", "", "77.6", "67.5", "", "49.3", "", "2", "", "", "101", "1", "1", "100", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "80.0", "78.5", "", "", "", "", "78.8"]} +{"pcdb_id": 5937, "brand_name": "Ideal", "model_name": "Classic", "model_qualifier": "LX FF260", "winter_efficiency_pct": 77.8, "summer_efficiency_pct": 67.7, "comparative_hot_water_efficiency_pct": 49.4, "output_kw_max": 17.6, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["005937", "000008", "0", "2018/Oct/15 12:00", "Caradon Plumbing", "Ideal", "Classic", "LX FF260", "G.C.41 387 27", "", "2001", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "14.7", "17.6", "", "", "77.8", "67.7", "", "49.4", "", "2", "", "", "101", "1", "1", "100", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.8", "78.9", "", "", "", "", "79.1"]} +{"pcdb_id": 5938, "brand_name": "Ideal", "model_name": "Classic", "model_qualifier": "LX FF270", "winter_efficiency_pct": 78.1, "summer_efficiency_pct": 68.0, "comparative_hot_water_efficiency_pct": 49.7, "output_kw_max": 20.5, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["005938", "000008", "0", "2018/Oct/15 12:00", "Caradon Plumbing", "Ideal", "Classic", "LX FF270", "G.C.41 387 28", "", "2001", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "17.6", "20.5", "", "", "78.1", "68.0", "", "49.7", "", "2", "", "", "101", "1", "1", "100", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.6", "79.7", "", "", "", "", "79.7"]} +{"pcdb_id": 5939, "brand_name": "Ideal", "model_name": "Classic", "model_qualifier": "LX FF280", "winter_efficiency_pct": 77.4, "summer_efficiency_pct": 67.3, "comparative_hot_water_efficiency_pct": 49.2, "output_kw_max": 23.4, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["005939", "000008", "0", "2018/Oct/15 12:00", "Caradon Plumbing", "Ideal", "Classic", "LX FF280", "G.C.41 387 29", "", "2001", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "20.5", "23.4", "", "", "77.4", "67.3", "", "49.2", "", "2", "", "", "101", "1", "1", "100", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.6", "78.5", "", "", "", "", "78.7"]} +{"pcdb_id": 5940, "brand_name": "Ideal", "model_name": "Mexico Slimline", "model_qualifier": "RS3/40", "winter_efficiency_pct": 75.5, "summer_efficiency_pct": 65.4, "comparative_hot_water_efficiency_pct": 47.8, "output_kw_max": 11.7, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["005940", "000008", "0", "2018/Oct/15 12:00", "Caradon Plumbing", "Ideal", "Mexico Slimline", "RS3/40", "G.C.No 41 348 04", "", "2001", "1", "1", "1", "1", "0", "", "", "1", "2", "1", "8.8", "11.7", "", "", "75.5", "65.4", "", "47.8", "", "2", "", "", "101", "2", "1", "5", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "80.9", "81.3", "", "", "", "", "81.2"]} +{"pcdb_id": 5941, "brand_name": "Ideal", "model_name": "Mexico Slimline", "model_qualifier": "CF3/40", "winter_efficiency_pct": 71.7, "summer_efficiency_pct": 61.6, "comparative_hot_water_efficiency_pct": 45.0, "output_kw_max": 11.7, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["005941", "000008", "0", "2018/Oct/15 12:00", "Caradon Plumbing", "Ideal", "Mexico Slimline", "CF3/40", "G.C.No 41 348 01", "", "2001", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "8.8", "11.7", "", "", "71.7", "61.6", "", "45.0", "", "2", "", "", "101", "2", "1", "5", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "78.7", "75.9", "", "", "", "", "76.4"]} +{"pcdb_id": 5942, "brand_name": "Ideal", "model_name": "Mexico Slimline", "model_qualifier": "CF3/50", "winter_efficiency_pct": 72.5, "summer_efficiency_pct": 62.4, "comparative_hot_water_efficiency_pct": 45.6, "output_kw_max": 14.7, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["005942", "000008", "0", "2018/Oct/15 12:00", "Caradon Plumbing", "Ideal", "Mexico Slimline", "CF3/50", "G.C.No 41 348 03", "", "2001", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "11.7", "14.7", "", "", "72.5", "62.4", "", "45.6", "", "2", "", "", "101", "2", "1", "5", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "78.6", "77.6", "", "", "", "", "77.8"]} +{"pcdb_id": 5943, "brand_name": "Ideal", "model_name": "Mexico Super", "model_qualifier": "CF3/100P", "winter_efficiency_pct": 74.7, "summer_efficiency_pct": 64.6, "comparative_hot_water_efficiency_pct": 47.2, "output_kw_max": 29.3, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["005943", "000008", "0", "2018/Oct/15 12:00", "Caradon Plumbing", "Ideal", "Mexico Super", "CF3/100P", "G.C.No 41 349 24", "", "2001", "2", "1", "1", "1", "0", "", "", "1", "1", "1", "29.3", "29.3", "", "", "74.7", "64.6", "", "47.2", "", "2", "0", "", "101", "2", "1", "5", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.7", "78.8", "", "", "", "", "79.4"]} +{"pcdb_id": 5944, "brand_name": "Ideal", "model_name": "Mexico Super", "model_qualifier": "CF3/125P", "winter_efficiency_pct": 75.4, "summer_efficiency_pct": 65.3, "comparative_hot_water_efficiency_pct": 47.7, "output_kw_max": 35.6, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["005944", "000008", "0", "2018/Oct/15 12:00", "Caradon Plumbing", "Ideal", "Mexico Super", "CF3/125P", "G.C.No 41 349 25", "", "2001", "2", "1", "1", "1", "0", "", "", "1", "1", "1", "35.6", "35.6", "", "", "75.4", "65.3", "", "47.7", "", "2", "0", "", "101", "2", "1", "5", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.2", "79.9", "", "", "", "", "80.3"]} +{"pcdb_id": 5945, "brand_name": "Ideal", "model_name": "Mexico Super", "model_qualifier": "CF3/140P", "winter_efficiency_pct": 75.7, "summer_efficiency_pct": 65.6, "comparative_hot_water_efficiency_pct": 47.9, "output_kw_max": 44.3, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["005945", "000008", "0", "2018/Oct/15 12:00", "Caradon Plumbing", "Ideal", "Mexico Super", "CF3/140P", "G.C.No 41 349 26", "", "2001", "2", "1", "1", "1", "0", "", "", "1", "1", "1", "44.3", "44.3", "", "", "75.7", "65.6", "", "47.9", "", "2", "0", "", "101", "2", "1", "5", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.7", "79.9", "", "", "", "", "80.4"]} +{"pcdb_id": 5946, "brand_name": "Ideal", "model_name": "Systemiser", "model_qualifier": "SE", "winter_efficiency_pct": 86.8, "summer_efficiency_pct": 77.8, "comparative_hot_water_efficiency_pct": 56.8, "output_kw_max": 24.0, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["005946", "000008", "0", "2012/Mar/27 10:12", "Caradon Plumbing", "Ideal", "Systemiser", "SE", "G.C.No 41 349 70", "", "2001", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24.0", "24.0", "", "", "86.8", "77.8", "", "56.8", "", "2", "", "", "102", "1", "2", "126", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "86.5", "94.3", "", "", "", "", "92.8"]} +{"pcdb_id": 5947, "brand_name": "Ideal", "model_name": "Minimser", "model_qualifier": "SE30", "winter_efficiency_pct": 83.9, "summer_efficiency_pct": 76.3, "comparative_hot_water_efficiency_pct": 55.8, "output_kw_max": 8.8, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["005947", "000008", "0", "2012/Mar/27 10:12", "Caradon Plumbing", "Ideal", "Minimser", "SE30", "G.C.No 41 349 64", "", "2001", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "", "8.8", "", "", "83.9", "76.3", "", "55.8", "", "2", "", "", "101", "1", "1", "50", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "86.5", "90.6", "", "", "", "", "89.9"]} +{"pcdb_id": 5948, "brand_name": "Ideal", "model_name": "Minimser", "model_qualifier": "SE40", "winter_efficiency_pct": 84.2, "summer_efficiency_pct": 76.6, "comparative_hot_water_efficiency_pct": 56.0, "output_kw_max": 11.7, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["005948", "000008", "0", "2012/Mar/27 10:12", "Caradon Plumbing", "Ideal", "Minimser", "SE40", "G.C.No 41 349 65", "", "2001", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "", "11.7", "", "", "84.2", "76.6", "", "56.0", "", "2", "", "", "101", "1", "1", "50", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "87.3", "91.0", "", "", "", "", "90.3"]} +{"pcdb_id": 5949, "brand_name": "Ideal", "model_name": "Minimser", "model_qualifier": "SE50", "winter_efficiency_pct": 84.1, "summer_efficiency_pct": 76.5, "comparative_hot_water_efficiency_pct": 55.8, "output_kw_max": 14.7, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["005949", "000008", "0", "2012/Mar/27 10:12", "Caradon Plumbing", "Ideal", "Minimser", "SE50", "G.C.No 41 349 66", "", "2001", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "", "14.7", "", "", "84.1", "76.5", "", "55.8", "", "2", "", "", "101", "1", "1", "50", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "87.0", "90.7", "", "", "", "", "90.0"]} +{"pcdb_id": 5950, "brand_name": "Ideal", "model_name": "Minimser", "model_qualifier": "SE60", "winter_efficiency_pct": 84.0, "summer_efficiency_pct": 76.4, "comparative_hot_water_efficiency_pct": 55.8, "output_kw_max": 17.6, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["005950", "000008", "0", "2012/Mar/27 10:12", "Caradon Plumbing", "Ideal", "Minimser", "SE60", "G.C.No 41 349 67", "", "2001", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "", "17.6", "", "", "84.0", "76.4", "", "55.8", "", "2", "", "", "101", "1", "1", "50", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "87.0", "90.6", "", "", "", "", "90.0"]} +{"pcdb_id": 5951, "brand_name": "Ideal", "model_name": "Minimser", "model_qualifier": "SE70", "winter_efficiency_pct": 84.1, "summer_efficiency_pct": 76.5, "comparative_hot_water_efficiency_pct": 55.9, "output_kw_max": 20.5, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["005951", "000008", "0", "2012/Mar/27 10:12", "Caradon Plumbing", "Ideal", "Minimser", "SE70", "G.C.No 41 349 68", "", "2001", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "", "20.5", "", "", "84.1", "76.5", "", "55.9", "", "2", "", "", "101", "1", "1", "50", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "87.0", "90.9", "", "", "", "", "90.2"]} +{"pcdb_id": 5952, "brand_name": "Ideal", "model_name": "Minimser", "model_qualifier": "SE80", "winter_efficiency_pct": 84.0, "summer_efficiency_pct": 76.4, "comparative_hot_water_efficiency_pct": 55.8, "output_kw_max": 23.4, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["005952", "000008", "0", "2012/Mar/27 10:12", "Caradon Plumbing", "Ideal", "Minimser", "SE80", "G.C.No 41 349 69", "", "2001", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "", "23.4", "", "", "84.0", "76.4", "", "55.8", "", "2", "", "", "101", "1", "1", "50", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "86.9", "90.6", "", "", "", "", "89.9"]} +{"pcdb_id": 5953, "brand_name": "Ideal", "model_name": "Response", "model_qualifier": "80", "winter_efficiency_pct": 80.3, "summer_efficiency_pct": 70.2, "comparative_hot_water_efficiency_pct": 49.4, "output_kw_max": 17.6, "final_year_of_manufacture": 2002, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["005953", "000008", "0", "2006/Jan/17 12:55", "Caradon Plumbing", "Ideal", "Response", "80", "G.C.No 47 348 02", "", "2002", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "17.6", "17.6", "", "", "80.3", "70.2", "", "49.4", "", "2", "", "", "104", "1", "2", "160", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "80.7", "82.4", "", "", "", "", "82.0"]} +{"pcdb_id": 5954, "brand_name": "Ideal", "model_name": "Response", "model_qualifier": "100", "winter_efficiency_pct": 80.9, "summer_efficiency_pct": 70.8, "comparative_hot_water_efficiency_pct": 49.8, "output_kw_max": 23.4, "final_year_of_manufacture": 2002, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["005954", "000008", "0", "2006/Jan/17 12:55", "Caradon Plumbing", "Ideal", "Response", "100", "G.C.No 47 348 04", "", "2002", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "23.4", "23.4", "", "", "80.9", "70.8", "", "49.8", "", "2", "", "", "104", "1", "2", "160", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.0", "83.3", "", "", "", "", "82.8"]} +{"pcdb_id": 5955, "brand_name": "Ideal", "model_name": "Response", "model_qualifier": "120", "winter_efficiency_pct": 80.9, "summer_efficiency_pct": 70.8, "comparative_hot_water_efficiency_pct": 49.8, "output_kw_max": 23.4, "final_year_of_manufacture": 2003, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["005955", "000008", "0", "2006/Jan/17 12:55", "Caradon Plumbing", "Ideal", "Response", "120", "G.C.No 47 348 01", "", "2003", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "23.4", "23.4", "", "", "80.9", "70.8", "", "49.8", "", "2", "", "", "104", "1", "2", "160", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.0", "83.3", "", "", "", "", "82.8"]} +{"pcdb_id": 5956, "brand_name": "Ideal", "model_name": "Response", "model_qualifier": "SE", "winter_efficiency_pct": 86.8, "summer_efficiency_pct": 78.2, "comparative_hot_water_efficiency_pct": 55.0, "output_kw_max": 24.0, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["005956", "000008", "0", "2006/Jan/17 12:55", "Caradon Plumbing", "Ideal", "Response", "SE", "G.C.No 47 348 03", "", "2001", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.0", "24.0", "", "", "86.8", "78.2", "", "55.0", "", "2", "", "", "104", "1", "2", "126", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "86.5", "94.3", "", "", "", "", "92.8"]} +{"pcdb_id": 5957, "brand_name": "Ideal", "model_name": "Concord", "model_qualifier": "CXD40", "winter_efficiency_pct": 77.2, "summer_efficiency_pct": 66.5, "comparative_hot_water_efficiency_pct": 48.5, "output_kw_max": 42.0, "final_year_of_manufacture": 2000, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["005957", "000008", "0", "2012/Mar/27 10:12", "Caradon Plumbing", "Ideal", "Concord", "CXD40", "P.I.No 87/AQ/103", "", "2000", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "42", "42", "", "", "77.2", "66.5", "", "48.5", "", "2", "", "", "102", "1", "2", "10", "1", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "79.2", "77.1", "", "", "", "", "77.5"]} +{"pcdb_id": 5958, "brand_name": "Ideal", "model_name": "Concord", "model_qualifier": "CXD50", "winter_efficiency_pct": 77.2, "summer_efficiency_pct": 66.5, "comparative_hot_water_efficiency_pct": 48.6, "output_kw_max": 50.0, "final_year_of_manufacture": 2000, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["005958", "000008", "0", "2012/Mar/27 10:12", "Caradon Plumbing", "Ideal", "Concord", "CXD50", "P.I.No 87/AQ/103", "", "2000", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "50", "50", "", "", "77.2", "66.5", "", "48.6", "", "2", "", "", "102", "1", "2", "10", "1", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "79.5", "76.9", "", "", "", "", "77.4"]} +{"pcdb_id": 5959, "brand_name": "Ideal", "model_name": "Concord", "model_qualifier": "CXD60", "winter_efficiency_pct": 78.7, "summer_efficiency_pct": 68.0, "comparative_hot_water_efficiency_pct": 49.7, "output_kw_max": 60.08, "final_year_of_manufacture": 2000, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["005959", "000008", "0", "2012/Mar/27 10:12", "Caradon Plumbing", "Ideal", "Concord", "CXD60", "P.I.No 87/AQ/103", "", "2000", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "60.08", "60.08", "", "", "78.7", "68.0", "", "49.7", "", "2", "", "", "102", "1", "2", "10", "1", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "80.7", "78.7", "", "", "", "", "79.1"]} +{"pcdb_id": 5964, "brand_name": "Ideal", "model_name": "Concord", "model_qualifier": "CX50", "winter_efficiency_pct": 73.3, "summer_efficiency_pct": 63.2, "comparative_hot_water_efficiency_pct": 46.2, "output_kw_max": 50.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["005964", "000008", "0", "2012/Mar/27 10:12", "Caradon Plumbing", "Ideal", "Concord", "CX50", "P.I.No 87/AP/80", "", "current", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "50", "50", "", "", "73.3", "63.2", "", "46.2", "", "2", "", "", "101", "2", "1", "5", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.5", "78.4", "", "", "", "", "78.6"]} +{"pcdb_id": 5965, "brand_name": "Ideal", "model_name": "Concord", "model_qualifier": "CX60", "winter_efficiency_pct": 74.4, "summer_efficiency_pct": 64.3, "comparative_hot_water_efficiency_pct": 47.0, "output_kw_max": 60.08, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["005965", "000008", "0", "2012/Mar/27 10:12", "Caradon Plumbing", "Ideal", "Concord", "CX60", "P.I.No 87/AP/80", "", "current", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "60.08", "60.08", "", "", "74.4", "64.3", "", "47.0", "", "2", "", "", "101", "2", "1", "5", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "80.7", "79.3", "", "", "", "", "79.6"]} +{"pcdb_id": 5977, "brand_name": "Ideal", "model_name": "Concord", "model_qualifier": "CXC48", "winter_efficiency_pct": 84.7, "summer_efficiency_pct": 75.7, "comparative_hot_water_efficiency_pct": 55.3, "output_kw_max": 48.83, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["005977", "000008", "0", "2012/Mar/27 10:12", "Caradon Plumbing", "Ideal", "Concord", "CXC48", "P.I.No 87/AQ/340", "", "current", "1", "1", "1", "1", "0", "", "", "2", "1", "2", "48.83", "48.83", "", "", "84.7", "75.7", "", "55.3", "", "2", "", "", "102", "1", "2", "110", "1", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "84.8", "90.7", "", "", "", "", "89.6"]} +{"pcdb_id": 5978, "brand_name": "Ideal", "model_name": "Concord", "model_qualifier": "CXC70", "winter_efficiency_pct": 84.5, "summer_efficiency_pct": 75.5, "comparative_hot_water_efficiency_pct": 55.2, "output_kw_max": 69.84, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["005978", "000008", "0", "2012/Mar/27 10:12", "Caradon Plumbing", "Ideal", "Concord", "CXC70", "P.I.No 87/AQ/340", "", "current", "1", "1", "1", "1", "0", "", "", "2", "1", "2", "69.84", "69.84", "", "", "84.5", "75.5", "", "55.2", "", "2", "", "", "102", "1", "2", "110", "1", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "85.1", "90.0", "", "", "", "", "89.1"]} +{"pcdb_id": 5981, "brand_name": "Atmos", "model_name": "Multi", "model_qualifier": "24/80 Plus", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 81.3, "comparative_hot_water_efficiency_pct": 50.7, "output_kw_max": 24.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["005981", "000141", "0", "2024/Jan/31 10:17", "Daalderop bv Netherlands", "Atmos", "Multi", "24/80 Plus", "CCB24/80+", "1995", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "1", "24", "24", "", "", "88.4", "81.3", "", "50.7", "", "2", "", "", "106", "1", "2", "67", "11", "2", "2", "0", "79.2", "0", "35", "2", "60", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.1", "98.3", "", "", "", "", "96.2"]} +{"pcdb_id": 5983, "brand_name": "Atmos", "model_name": "Multi", "model_qualifier": "24/80", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 81.3, "comparative_hot_water_efficiency_pct": 50.3, "output_kw_max": 24.0, "final_year_of_manufacture": 2010, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["005983", "000141", "0", "2024/Jan/31 10:17", "Daalderop bv Netherlands", "Atmos", "Multi", "24/80", "CCB24/80", "1993", "2010", "1", "2", "1", "2", "0", "", "", "2", "2", "1", "24", "24", "", "", "88.4", "81.3", "", "50.3", "", "2", "", "", "106", "1", "2", "67", "11", "2", "2", "0", "82.2", "0", "35", "2", "60", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.1", "98.3", "", "", "", "", "96.2"]} +{"pcdb_id": 5984, "brand_name": "Atmos", "model_name": "Multi", "model_qualifier": "32/80", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 81.2, "comparative_hot_water_efficiency_pct": 50.2, "output_kw_max": 32.0, "final_year_of_manufacture": 2010, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["005984", "000141", "0", "2024/Jan/31 10:17", "Daalderop bv Netherlands", "Atmos", "Multi", "32/80", "CCB32/80", "1997", "2010", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "32", "32", "", "", "88.4", "81.2", "", "50.2", "", "2", "", "", "106", "1", "2", "67", "11", "2", "2", "0", "82.5", "0", "35", "2", "60", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "86.3", "98.4", "", "", "", "", "96.1"]} +{"pcdb_id": 5985, "brand_name": "Atmos", "model_name": "Multi", "model_qualifier": "32/80 Plus", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 81.2, "comparative_hot_water_efficiency_pct": 50.6, "output_kw_max": 32.0, "final_year_of_manufacture": 2010, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["005985", "000141", "0", "2024/Jan/31 10:17", "Daalderop bv Netherlands", "Atmos", "Multi", "32/80 Plus", "CCB32/80+", "1997", "2010", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "32", "32", "", "", "88.4", "81.2", "", "50.6", "", "2", "", "", "106", "1", "2", "67", "11", "2", "2", "0", "79.5", "0", "35", "2", "60", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "86.3", "98.4", "", "", "", "", "96.1"]} +{"pcdb_id": 5986, "brand_name": "Worcester", "model_name": "25 Si", "model_qualifier": "RSF", "winter_efficiency_pct": 82.0, "summer_efficiency_pct": 71.9, "comparative_hot_water_efficiency_pct": 50.5, "output_kw_max": 25.0, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["005986", "000035", "0", "2002/Jun/10 10:51", "Worcester Heat Systems", "Worcester", "25 Si", "RSF", "47 311 50", "2000", "2001", "2", "2", "1", "2", "0", "", "", "1", "2", "2", "25", "25", "", "", "82.0", "71.9", "", "50.5", "", "2", "0", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "86.0", "81.6", "", "", "", "", "82.4"]} +{"pcdb_id": 5987, "brand_name": "Worcester", "model_name": "25 Si", "model_qualifier": "RSF", "winter_efficiency_pct": 78.6, "summer_efficiency_pct": 68.5, "comparative_hot_water_efficiency_pct": 48.2, "output_kw_max": 25.0, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["005987", "000035", "0", "2001/Nov/22 08:38", "Worcester Heat Systems", "Worcester", "25 Si", "RSF", "47 311 49", "2000", "2001", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "25", "25", "", "", "78.6", "68.5", "", "48.2", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "83.6", "76.7", "", "", "", "", "78.0"]} +{"pcdb_id": 5988, "brand_name": "Worcester", "model_name": "28 Si", "model_qualifier": "RSF", "winter_efficiency_pct": 82.3, "summer_efficiency_pct": 72.2, "comparative_hot_water_efficiency_pct": 50.8, "output_kw_max": 28.0, "final_year_of_manufacture": 2002, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["005988", "000035", "0", "2002/Aug/14 10:52", "Worcester Heat Systems", "Worcester", "28 Si", "RSF", "47 311 52", "2000", "2002", "2", "2", "1", "2", "0", "", "", "1", "2", "2", "28", "28", "", "", "82.3", "72.2", "", "50.8", "", "2", "0", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "86.4", "82.3", "", "", "", "", "83.1"]} +{"pcdb_id": 5989, "brand_name": "Worcester", "model_name": "28 Si", "model_qualifier": "RSF", "winter_efficiency_pct": 79.1, "summer_efficiency_pct": 69.0, "comparative_hot_water_efficiency_pct": 48.5, "output_kw_max": 28.0, "final_year_of_manufacture": 2002, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["005989", "000035", "0", "2002/Aug/14 10:50", "Worcester Heat Systems", "Worcester", "28 Si", "RSF", "47 311 51", "2000", "2002", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "28", "28", "", "", "79.1", "69.0", "", "48.5", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "84.0", "77.7", "", "", "", "", "78.9"]} +{"pcdb_id": 8050, "brand_name": "Vokera", "model_name": "Linea", "model_qualifier": "Linea 24", "winter_efficiency_pct": 81.2, "summer_efficiency_pct": 71.1, "comparative_hot_water_efficiency_pct": 50.0, "output_kw_max": 23.7, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008050", "000011", "0", "2006/Jan/17 12:31", "Vokera", "Vokera", "Linea", "Linea 24", "4709427", "1998", "current", "2", "2", "1", "2", "0", "", "", "1", "2", "2", "23.7", "23.7", "", "", "81.2", "71.1", "", "50.0", "", "2", "0", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "84.1", "80.8", "", "", "", "", "81.4"]} +{"pcdb_id": 8051, "brand_name": "Vokera", "model_name": "Linea 24", "model_qualifier": "", "winter_efficiency_pct": 78.4, "summer_efficiency_pct": 68.3, "comparative_hot_water_efficiency_pct": 48.1, "output_kw_max": 23.7, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008051", "000011", "0", "2006/Jan/17 12:55", "Vokera", "Vokera", "Linea 24", "", "47-094-27", "1998", "2001", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "23.7", "23.7", "", "", "78.4", "68.3", "", "48.1", "", "2", "", "", "104", "1", "2", "125", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.2", "77.1", "", "", "", "", "78.1"]} +{"pcdb_id": 8052, "brand_name": "Vokera", "model_name": "Linea", "model_qualifier": "Linea 28", "winter_efficiency_pct": 81.5, "summer_efficiency_pct": 71.4, "comparative_hot_water_efficiency_pct": 50.2, "output_kw_max": 28.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008052", "000011", "0", "2006/Jan/17 12:31", "Vokera", "Vokera", "Linea", "Linea 28", "4709428", "1998", "current", "2", "2", "1", "2", "0", "", "", "1", "2", "2", "28", "28", "", "", "81.5", "71.4", "", "50.2", "", "2", "0", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "84.5", "80.9", "", "", "", "", "81.5"]} +{"pcdb_id": 8053, "brand_name": "Vokera", "model_name": "Linea 28", "model_qualifier": "", "winter_efficiency_pct": 78.5, "summer_efficiency_pct": 68.4, "comparative_hot_water_efficiency_pct": 48.1, "output_kw_max": 28.0, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008053", "000011", "0", "2006/Jan/17 12:55", "Vokera", "Vokera", "Linea 28", "", "47-094-28", "1998", "2001", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "28", "28", "", "", "78.5", "68.4", "", "48.1", "", "2", "", "", "104", "1", "2", "125", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.7", "77.7", "", "", "", "", "78.4"]} +{"pcdb_id": 8055, "brand_name": "Vokera", "model_name": "Eclipse ESC", "model_qualifier": "", "winter_efficiency_pct": 84.9, "summer_efficiency_pct": 76.3, "comparative_hot_water_efficiency_pct": 53.7, "output_kw_max": 25.3, "final_year_of_manufacture": 2010, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008055", "000011", "0", "2010/Oct/21 11:01", "Vokera", "Vokera", "Eclipse ESC", "", "47-094-24", "1996", "2010", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "25.3", "25.3", "", "", "84.9", "76.3", "", "53.7", "", "2", "", "", "104", "1", "2", "130", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.2", "89.3", "", "", "", "", "88.9"]} +{"pcdb_id": 8056, "brand_name": "Vokera", "model_name": "Linea Plus", "model_qualifier": "", "winter_efficiency_pct": 81.0, "summer_efficiency_pct": 70.9, "comparative_hot_water_efficiency_pct": 49.9, "output_kw_max": 30.0, "final_year_of_manufacture": 2000, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008056", "000011", "0", "2006/Jan/17 12:55", "Vokera", "Vokera", "Linea Plus", "", "47-094-29", "1998", "2000", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "30", "30", "", "", "81.0", "70.9", "", "49.9", "", "2", "", "", "104", "1", "2", "160", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.4", "82.0", "", "", "", "", "82.1"]} +{"pcdb_id": 8057, "brand_name": "Vokera", "model_name": "Eclipse ESS", "model_qualifier": "", "winter_efficiency_pct": 84.9, "summer_efficiency_pct": 75.9, "comparative_hot_water_efficiency_pct": 55.5, "output_kw_max": 25.3, "final_year_of_manufacture": 2010, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008057", "000011", "0", "2012/Mar/27 10:12", "Vokera", "Vokera", "Eclipse ESS", "", "41-094-10", "1996", "2010", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "25.3", "25.3", "", "", "84.9", "75.9", "", "55.5", "", "2", "", "", "102", "1", "2", "130", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.2", "89.3", "", "", "", "", "88.9"]} +{"pcdb_id": 8059, "brand_name": "Warmflow", "model_name": "120/150 Bluebird", "model_qualifier": "", "winter_efficiency_pct": 86.5, "summer_efficiency_pct": 74.8, "comparative_hot_water_efficiency_pct": 54.7, "output_kw_max": 43.95, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008059", "000063", "0", "2019/Dec/19 11:37", "Warmflow Engineering", "Warmflow", "120/150 Bluebird", "", "", "1996", "current", "4", "1", "2", "1", "0", "", "", "1", "1", "2", "35.16", "43.95", "", "", "86.5", "74.8", "", "54.7", "", "2", "", "", "201", "1", "1", "150", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.9", "88.0", "", "", "", "", "87.6"]} +{"pcdb_id": 8060, "brand_name": "Warmflow", "model_name": "90/120 Bluebird", "model_qualifier": "", "winter_efficiency_pct": 85.4, "summer_efficiency_pct": 73.7, "comparative_hot_water_efficiency_pct": 53.8, "output_kw_max": 35.16, "final_year_of_manufacture": 2000, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008060", "000063", "0", "2012/Mar/27 10:12", "Warmflow Engineering", "Warmflow", "90/120 Bluebird", "", "", "1996", "2000", "4", "1", "2", "1", "0", "", "", "1", "1", "2", "26.37", "35.16", "", "", "85.4", "73.7", "", "53.8", "", "2", "", "", "201", "1", "1", "150", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "84.8", "85.9", "", "", "", "", "85.7"]} +{"pcdb_id": 8061, "brand_name": "Warmflow", "model_name": "70/90 Bluebird", "model_qualifier": "", "winter_efficiency_pct": 83.0, "summer_efficiency_pct": 71.3, "comparative_hot_water_efficiency_pct": 52.1, "output_kw_max": 26.37, "final_year_of_manufacture": 2000, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008061", "000063", "0", "2012/Mar/27 10:12", "Warmflow Engineering", "Warmflow", "70/90 Bluebird", "", "", "1996", "2000", "4", "1", "2", "1", "0", "", "", "1", "1", "2", "20.51", "26.37", "", "", "83.0", "71.3", "", "52.1", "", "2", "", "", "201", "1", "1", "150", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "83.1", "82.8", "", "", "", "", "82.9"]} +{"pcdb_id": 8062, "brand_name": "Warmflow", "model_name": "50/70 Bluebird", "model_qualifier": "", "winter_efficiency_pct": 86.5, "summer_efficiency_pct": 74.8, "comparative_hot_water_efficiency_pct": 54.7, "output_kw_max": 20.51, "final_year_of_manufacture": 2000, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008062", "000063", "0", "2012/Mar/27 10:12", "Warmflow Engineering", "Warmflow", "50/70 Bluebird", "", "", "1996", "2000", "4", "1", "2", "1", "0", "", "", "1", "1", "2", "14.65", "20.51", "", "", "86.5", "74.8", "", "54.7", "", "2", "", "", "201", "1", "1", "145", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.9", "88.8", "", "", "", "", "88.3"]} +{"pcdb_id": 8063, "brand_name": "Ideal", "model_name": "Mexico Super", "model_qualifier": "CF3/70", "winter_efficiency_pct": 73.6, "summer_efficiency_pct": 63.5, "comparative_hot_water_efficiency_pct": 46.3, "output_kw_max": 20.5, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008063", "000008", "0", "2018/Oct/15 12:00", "Caradon Plumbing", "Ideal", "Mexico Super", "CF3/70", "G.C.No 41 348 14", "", "2001", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "17.6", "20.5", "", "", "73.6", "63.5", "", "46.3", "", "2", "", "", "101", "2", "1", "5", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "80.4", "77.9", "", "", "", "", "78.4"]} +{"pcdb_id": 8064, "brand_name": "Ideal", "model_name": "Mexico Super", "model_qualifier": "CF3/80", "winter_efficiency_pct": 73.2, "summer_efficiency_pct": 63.1, "comparative_hot_water_efficiency_pct": 46.1, "output_kw_max": 23.4, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008064", "000008", "0", "2018/Oct/15 12:00", "Caradon Plumbing", "Ideal", "Mexico Super", "CF3/80", "G.C.No 41 348 16", "", "2001", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "20.5", "23.4", "", "", "73.2", "63.1", "", "46.1", "", "2", "", "", "101", "2", "1", "5", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.5", "78.2", "", "", "", "", "78.4"]} +{"pcdb_id": 8065, "brand_name": "Ideal", "model_name": "Mexico Super", "model_qualifier": "RS3/40", "winter_efficiency_pct": 73.7, "summer_efficiency_pct": 63.6, "comparative_hot_water_efficiency_pct": 46.5, "output_kw_max": 11.7, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008065", "000008", "0", "2018/Oct/15 12:00", "Caradon Plumbing", "Ideal", "Mexico Super", "RS3/40", "G.C.No 41 349 27", "", "2001", "1", "1", "1", "1", "0", "", "", "1", "2", "1", "8.8", "11.7", "", "", "73.7", "63.6", "", "46.5", "", "2", "", "", "101", "2", "1", "5", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.6", "79.1", "", "", "", "", "79.2"]} +{"pcdb_id": 8066, "brand_name": "Ideal", "model_name": "Mexico Super", "model_qualifier": "RS3/50", "winter_efficiency_pct": 73.0, "summer_efficiency_pct": 62.9, "comparative_hot_water_efficiency_pct": 45.9, "output_kw_max": 14.7, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008066", "000008", "0", "2018/Oct/15 12:00", "Caradon Plumbing", "Ideal", "Mexico Super", "RS3/50", "G.C.No 41 349 28", "", "2001", "1", "1", "1", "1", "0", "", "", "1", "2", "1", "11.7", "14.7", "", "", "73.0", "62.9", "", "45.9", "", "2", "", "", "101", "2", "1", "5", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.9", "77.2", "", "", "", "", "77.7"]} +{"pcdb_id": 8067, "brand_name": "Ideal", "model_name": "Mexico Super", "model_qualifier": "RS3/60", "winter_efficiency_pct": 74.9, "summer_efficiency_pct": 64.8, "comparative_hot_water_efficiency_pct": 47.3, "output_kw_max": 17.6, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008067", "000008", "0", "2018/Oct/15 12:00", "Caradon Plumbing", "Ideal", "Mexico Super", "RS3/60", "G.C.No 41 349 29", "", "2001", "1", "1", "1", "1", "0", "", "", "1", "2", "1", "14.7", "17.6", "", "", "74.9", "64.8", "", "47.3", "", "2", "", "", "101", "2", "1", "5", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "80.2", "80.8", "", "", "", "", "80.7"]} +{"pcdb_id": 8068, "brand_name": "Ideal", "model_name": "Mexico Super", "model_qualifier": "RS3/100", "winter_efficiency_pct": 73.4, "summer_efficiency_pct": 63.3, "comparative_hot_water_efficiency_pct": 46.2, "output_kw_max": 29.3, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008068", "000008", "0", "2018/Oct/15 12:00", "Caradon Plumbing", "Ideal", "Mexico Super", "RS3/100", "G.C.No 41 349 32", "", "2001", "1", "1", "1", "1", "0", "", "", "1", "2", "1", "23.4", "29.3", "", "", "73.4", "63.3", "", "46.2", "", "2", "", "", "101", "2", "1", "5", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.6", "78.3", "", "", "", "", "78.6"]} +{"pcdb_id": 8069, "brand_name": "Ideal", "model_name": "Mexico Super", "model_qualifier": "RS3/70", "winter_efficiency_pct": 73.6, "summer_efficiency_pct": 63.5, "comparative_hot_water_efficiency_pct": 46.4, "output_kw_max": 20.5, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008069", "000008", "0", "2018/Oct/15 12:00", "Caradon Plumbing", "Ideal", "Mexico Super", "RS3/70", "G.C.No 41 349 30", "", "2001", "1", "1", "1", "1", "0", "", "", "1", "2", "1", "17.6", "20.5", "", "", "73.6", "63.5", "", "46.4", "", "2", "", "", "101", "2", "1", "5", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.8", "78.7", "", "", "", "", "78.9"]} +{"pcdb_id": 8070, "brand_name": "Ideal", "model_name": "Mexico Super", "model_qualifier": "RS3/80", "winter_efficiency_pct": 72.9, "summer_efficiency_pct": 62.8, "comparative_hot_water_efficiency_pct": 45.9, "output_kw_max": 23.4, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008070", "000008", "0", "2018/Oct/15 12:00", "Caradon Plumbing", "Ideal", "Mexico Super", "RS3/80", "G.C.No 41 349 31", "", "2001", "1", "1", "1", "1", "0", "", "", "1", "2", "1", "20.5", "23.4", "", "", "72.9", "62.8", "", "45.9", "", "2", "", "", "101", "2", "1", "5", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "78.7", "78.3", "", "", "", "", "78.4"]} +{"pcdb_id": 8071, "brand_name": "Ideal", "model_name": "Mexico Super", "model_qualifier": "RS3/125", "winter_efficiency_pct": 73.6, "summer_efficiency_pct": 63.5, "comparative_hot_water_efficiency_pct": 46.4, "output_kw_max": 35.8, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008071", "000008", "0", "2018/Oct/15 12:00", "Caradon Plumbing", "Ideal", "Mexico Super", "RS3/125", "G.C.No 41 349 33", "", "2001", "1", "1", "1", "1", "0", "", "", "1", "2", "1", "29.3", "35.8", "", "", "73.6", "63.5", "", "46.4", "", "2", "", "", "101", "2", "1", "5", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.3", "79.2", "", "", "", "", "79.2"]} +{"pcdb_id": 8072, "brand_name": "Ideal", "model_name": "Mexico Super", "model_qualifier": "CF3/60P", "winter_efficiency_pct": 75.3, "summer_efficiency_pct": 65.2, "comparative_hot_water_efficiency_pct": 47.6, "output_kw_max": 18.1, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008072", "000008", "0", "2018/Oct/15 12:00", "Caradon Plumbing", "Ideal", "Mexico Super", "CF3/60P", "G.C.No 41 348 99", "", "2001", "2", "1", "1", "1", "0", "", "", "1", "1", "1", "18.1", "18.1", "", "", "75.3", "65.2", "", "47.6", "", "2", "0", "", "101", "2", "1", "5", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.5", "80.3", "", "", "", "", "80.5"]} +{"pcdb_id": 8073, "brand_name": "Ideal", "model_name": "Mexico Super", "model_qualifier": "CF3/75P", "winter_efficiency_pct": 74.9, "summer_efficiency_pct": 64.8, "comparative_hot_water_efficiency_pct": 47.3, "output_kw_max": 22.2, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008073", "000008", "0", "2018/Oct/15 12:00", "Caradon Plumbing", "Ideal", "Mexico Super", "CF3/75P", "G.C.No 41 349 23", "", "2001", "2", "1", "1", "1", "0", "", "", "1", "1", "1", "22.2", "22.2", "", "", "74.9", "64.8", "", "47.3", "", "2", "0", "", "101", "2", "1", "5", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.2", "79.8", "", "", "", "", "80.0"]} +{"pcdb_id": 8074, "brand_name": "Ideal", "model_name": "Mexico Super", "model_qualifier": "RS3/60P", "winter_efficiency_pct": 76.1, "summer_efficiency_pct": 66.0, "comparative_hot_water_efficiency_pct": 48.2, "output_kw_max": 17.5, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008074", "000008", "0", "2018/Oct/15 12:00", "Caradon Plumbing", "Ideal", "Mexico Super", "RS3/60P", "G.C.No 41 349 34", "", "2001", "2", "1", "1", "1", "0", "", "", "1", "2", "1", "17.5", "17.5", "", "", "76.1", "66.0", "", "48.2", "", "2", "0", "", "101", "2", "1", "5", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.4", "82.1", "", "", "", "", "81.9"]} +{"pcdb_id": 8075, "brand_name": "Ideal", "model_name": "Mexico Super", "model_qualifier": "RS3/75P", "winter_efficiency_pct": 76.2, "summer_efficiency_pct": 66.1, "comparative_hot_water_efficiency_pct": 48.3, "output_kw_max": 23.2, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008075", "000008", "0", "2018/Oct/15 12:00", "Caradon Plumbing", "Ideal", "Mexico Super", "RS3/75P", "G.C.No 41 349 35", "", "2001", "2", "1", "1", "1", "0", "", "", "1", "2", "1", "23.2", "23.2", "", "", "76.2", "66.1", "", "48.3", "", "2", "0", "", "101", "2", "1", "5", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.1", "81.6", "", "", "", "", "81.7"]} +{"pcdb_id": 8076, "brand_name": "Ideal", "model_name": "Mexico Super", "model_qualifier": "RS3/100P", "winter_efficiency_pct": 75.6, "summer_efficiency_pct": 65.5, "comparative_hot_water_efficiency_pct": 47.8, "output_kw_max": 28.8, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008076", "000008", "0", "2018/Oct/15 12:00", "Caradon Plumbing", "Ideal", "Mexico Super", "RS3/100P", "G.C.No 41 349 36", "", "2001", "2", "1", "1", "1", "0", "", "", "1", "2", "1", "28.8", "28.8", "", "", "75.6", "65.5", "", "47.8", "", "2", "0", "", "101", "2", "1", "5", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "80.5", "81.9", "", "", "", "", "81.6"]} +{"pcdb_id": 8077, "brand_name": "Worcester", "model_name": "28i", "model_qualifier": "RSF", "winter_efficiency_pct": 78.9, "summer_efficiency_pct": 68.8, "comparative_hot_water_efficiency_pct": 48.4, "output_kw_max": 28.0, "final_year_of_manufacture": 2003, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008077", "000035", "0", "2020/Sep/02 14:14", "Worcester Heat Systems", "Worcester", "28i", "RSF", "47 311 54", "2000", "2003", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "28", "28", "", "", "78.9", "68.8", "", "48.4", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "83.9", "77.3", "", "", "", "", "78.6"]} +{"pcdb_id": 8083, "brand_name": "Kidd VHE", "model_name": "1", "model_qualifier": "Kerosene", "winter_efficiency_pct": 85.8, "summer_efficiency_pct": 78.0, "comparative_hot_water_efficiency_pct": 57.0, "output_kw_max": 27.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008083", "000204", "0", "2012/Mar/27 10:12", "Archie Kidd (Thermal)", "Kidd VHE", "1", "Kerosene", "", "1982", "current", "4", "1", "2", "1", "0", "", "", "2", "3", "1", "17.6", "27.2", "", "", "85.8", "78.0", "", "57.0", "", "2", "", "", "201", "1", "1", "90", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.4", "89.3", "", "", "", "", "89.7"]} +{"pcdb_id": 8086, "brand_name": "Glow-worm", "model_name": "Energysaver Combi 80", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 56.4, "output_kw_max": 24.6, "final_year_of_manufacture": 2003, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008086", "000207", "0", "2012/Mar/26 14:26", "Hepworth Heating", "Glow-worm", "Energysaver Combi 80", "", "47-047-01", "1998", "2003", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.6", "24.6", "", "", "88.8", "80.2", "", "56.4", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "0", "", "0005", "", "", "", "", "", "", "", "", "89.0", "98.4", "", "", "", "", "96.6"]} +{"pcdb_id": 8087, "brand_name": "Glow-worm", "model_name": "Energysaver Combi 100", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 56.3, "output_kw_max": 28.9, "final_year_of_manufacture": 2003, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008087", "000207", "0", "2012/Mar/26 14:24", "Hepworth Heating", "Glow-worm", "Energysaver Combi 100", "", "47-047-02", "1999", "2003", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28.9", "28.9", "", "", "88.6", "80.0", "", "56.3", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "0", "", "0005", "", "", "", "", "", "", "", "", "88.6", "98.1", "", "", "", "", "96.3"]} +{"pcdb_id": 8088, "brand_name": "Saunier Duval", "model_name": "Ecosy 24E", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 56.4, "output_kw_max": 24.6, "final_year_of_manufacture": 2003, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008088", "000206", "0", "2012/Mar/26 14:22", "Hepworth Heating", "Saunier Duval", "Ecosy 24E", "", "47-920-03", "1996", "2003", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.6", "24.6", "", "", "88.8", "80.2", "", "56.4", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "0", "", "0005", "", "", "", "", "", "", "", "", "89.0", "98.4", "", "", "", "", "96.6"]} +{"pcdb_id": 8089, "brand_name": "Saunier Duval", "model_name": "Ecosy 28E", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 56.3, "output_kw_max": 28.9, "final_year_of_manufacture": 2003, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008089", "000206", "0", "2012/Mar/26 14:18", "Hepworth Heating", "Saunier Duval", "Ecosy 28E", "", "47-920-04", "1997", "2003", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28.9", "28.9", "", "", "88.6", "80.0", "", "56.3", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "0", "", "0005", "", "", "", "", "", "", "", "", "88.6", "98.1", "", "", "", "", "96.3"]} +{"pcdb_id": 8090, "brand_name": "Saunier Duval", "model_name": "Ecosy SB28E", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 28.9, "final_year_of_manufacture": 2003, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008090", "000206", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Saunier Duval", "Ecosy SB28E", "", "41-920-22", "1997", "2003", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "28.9", "28.9", "", "", "88.6", "79.6", "", "58.2", "", "2", "", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.6", "98.1", "", "", "", "", "96.3"]} +{"pcdb_id": 8091, "brand_name": "Saunier Duval", "model_name": "Ecosy SB24E", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 24.6, "final_year_of_manufacture": 2003, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008091", "000206", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Saunier Duval", "Ecosy SB24E", "", "41-920-01", "1997", "2003", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24.6", "24.6", "", "", "88.8", "79.8", "", "58.3", "", "2", "", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.0", "98.4", "", "", "", "", "96.6"]} +{"pcdb_id": 8093, "brand_name": "Boulter", "model_name": "Camray 5", "model_qualifier": "150/200", "winter_efficiency_pct": 84.7, "summer_efficiency_pct": 73.0, "comparative_hot_water_efficiency_pct": 53.3, "output_kw_max": 58.6, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008093", "000041", "0", "2012/Mar/27 10:12", "Boulter Boilers", "Boulter", "Camray 5", "150/200", "", "2000", "2001", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "43.9", "58.6", "", "", "84.7", "73.0", "", "53.3", "", "2", "", "", "201", "1", "1", "150", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "83.8", "85.6", "", "", "", "", "85.3"]} +{"pcdb_id": 8096, "brand_name": "Boulter", "model_name": "Camray 5", "model_qualifier": "100/140 System", "winter_efficiency_pct": 81.2, "summer_efficiency_pct": 69.5, "comparative_hot_water_efficiency_pct": 50.8, "output_kw_max": 41.0, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008096", "000041", "0", "2012/Mar/27 10:12", "Boulter Boilers", "Boulter", "Camray 5", "100/140 System", "", "2000", "2001", "4", "1", "1", "1", "0", "", "", "1", "3", "2", "29.3", "41.0", "", "", "81.2", "69.5", "", "50.8", "", "2", "", "", "201", "1", "1", "115", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.8", "80.7", "", "", "", "", "80.9"]} +{"pcdb_id": 8097, "brand_name": "Boulter", "model_name": "Camray 5", "model_qualifier": "100/140 Utility", "winter_efficiency_pct": 81.2, "summer_efficiency_pct": 69.5, "comparative_hot_water_efficiency_pct": 50.8, "output_kw_max": 41.0, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008097", "000041", "0", "2012/Mar/27 10:12", "Boulter Boilers", "Boulter", "Camray 5", "100/140 Utility", "", "2000", "2001", "4", "1", "1", "1", "0", "", "", "1", "3", "2", "29.3", "41.0", "", "", "81.2", "69.5", "", "50.8", "", "2", "", "", "201", "1", "1", "115", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.8", "80.7", "", "", "", "", "80.9"]} +{"pcdb_id": 8098, "brand_name": "Boulter", "model_name": "Camray 5", "model_qualifier": "100/140", "winter_efficiency_pct": 81.2, "summer_efficiency_pct": 69.5, "comparative_hot_water_efficiency_pct": 50.8, "output_kw_max": 41.0, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008098", "000041", "0", "2012/Mar/27 10:12", "Boulter Boilers", "Boulter", "Camray 5", "100/140", "", "2000", "2001", "4", "1", "1", "1", "0", "", "", "1", "3", "2", "29.3", "41.0", "", "", "81.2", "69.5", "", "50.8", "", "2", "", "", "201", "1", "1", "115", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.8", "80.7", "", "", "", "", "80.9"]} +{"pcdb_id": 8099, "brand_name": "Chaffoteaux et Maury", "model_name": "Britony Combi 100", "model_qualifier": "", "winter_efficiency_pct": 79.3, "summer_efficiency_pct": 69.2, "comparative_hot_water_efficiency_pct": 48.7, "output_kw_max": 28.0, "final_year_of_manufacture": 2002, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008099", "000010", "0", "2006/Jan/17 12:55", "Chaffoteaux et Maury", "Chaffoteaux et Maury", "Britony Combi 100", "", "", "1996", "2002", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "28.0", "28.0", "", "", "79.3", "69.2", "", "48.7", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.5", "78.5", "", "", "", "", "79.2"]} +{"pcdb_id": 8100, "brand_name": "Chaffoteaux et Maury", "model_name": "Britony Combi 80", "model_qualifier": "", "winter_efficiency_pct": 77.5, "summer_efficiency_pct": 67.4, "comparative_hot_water_efficiency_pct": 47.4, "output_kw_max": 23.25, "final_year_of_manufacture": 2002, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008100", "000010", "0", "2006/Jan/17 12:55", "Chaffoteaux et Maury", "Chaffoteaux et Maury", "Britony Combi 80", "", "", "1996", "2002", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "23.25", "23.25", "", "", "77.5", "67.4", "", "47.4", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.4", "76.1", "", "", "", "", "77.1"]} +{"pcdb_id": 8101, "brand_name": "Chaffoteaux et Maury", "model_name": "Calydra 80", "model_qualifier": "", "winter_efficiency_pct": 77.5, "summer_efficiency_pct": 67.4, "comparative_hot_water_efficiency_pct": 47.4, "output_kw_max": 23.25, "final_year_of_manufacture": 2002, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008101", "000010", "0", "2006/Jan/17 12:55", "Chaffoteaux et Maury", "Chaffoteaux et Maury", "Calydra 80", "", "49AQ566", "1998", "2002", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "23.25", "23.25", "", "", "77.5", "67.4", "", "47.4", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.4", "76.1", "", "", "", "", "77.1"]} +{"pcdb_id": 8102, "brand_name": "Chaffoteaux et Maury", "model_name": "Calydra 100", "model_qualifier": "", "winter_efficiency_pct": 79.3, "summer_efficiency_pct": 69.2, "comparative_hot_water_efficiency_pct": 48.7, "output_kw_max": 28.0, "final_year_of_manufacture": 2003, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008102", "000010", "0", "2006/Jan/17 12:55", "Chaffoteaux et Maury", "Chaffoteaux et Maury", "Calydra 100", "", "", "1998", "2003", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "28.0", "28.0", "", "", "79.3", "69.2", "", "48.7", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.5", "78.5", "", "", "", "", "79.2"]} +{"pcdb_id": 8103, "brand_name": "Chaffoteaux et Maury", "model_name": "Britony System 40", "model_qualifier": "", "winter_efficiency_pct": 77.1, "summer_efficiency_pct": 67.0, "comparative_hot_water_efficiency_pct": 47.1, "output_kw_max": 12.0, "final_year_of_manufacture": 2002, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008103", "000010", "0", "2006/Jan/17 12:55", "Chaffoteaux et Maury", "Chaffoteaux et Maury", "Britony System 40", "", "", "1997", "2002", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "12.0", "12.0", "", "", "77.1", "67.0", "", "47.1", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "78.9", "77.8", "", "", "", "", "78.0"]} +{"pcdb_id": 8104, "brand_name": "Vaillant", "model_name": "Ecomax", "model_qualifier": "828/1E", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 55.8, "output_kw_max": 22.4, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008104", "000031", "0", "2006/Jan/17 12:55", "Vaillant", "Vaillant", "Ecomax", "828/1E", "VUW GB 286 E-C", "2000", "2001", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "22.4", "22.4", "", "", "88.0", "79.4", "", "55.8", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "96.7", "", "", "", "", "95.1"]} +{"pcdb_id": 8105, "brand_name": "Vaillant", "model_name": "Ecomax", "model_qualifier": "824/1E", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 55.8, "output_kw_max": 18.4, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008105", "000031", "0", "2006/Jan/17 12:55", "Vaillant", "Vaillant", "Ecomax", "824/1E", "VUW GB 246 E-C", "2000", "2001", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "18.4", "18.4", "", "", "88.0", "79.4", "", "55.8", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.2", "96.6", "", "", "", "", "95.0"]} +{"pcdb_id": 8106, "brand_name": "Vaillant", "model_name": "Ecomax", "model_qualifier": "622E", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 22.4, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008106", "000031", "0", "2012/Mar/27 10:12", "Vaillant", "Vaillant", "Ecomax", "622E", "VU GB 246 E-C", "2000", "2001", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "22.4", "22.4", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "96.7", "", "", "", "", "95.1"]} +{"pcdb_id": 8107, "brand_name": "Vaillant", "model_name": "Ecomax", "model_qualifier": "618E", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 18.4, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008107", "000031", "0", "2012/Mar/27 10:12", "Vaillant", "Vaillant", "Ecomax", "618E", "VU GB 196 E-C", "2000", "2001", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18.4", "18.4", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.2", "96.6", "", "", "", "", "95.0"]} +{"pcdb_id": 8108, "brand_name": "Vaillant", "model_name": "Turbomax Plus", "model_qualifier": "824E", "winter_efficiency_pct": 80.6, "summer_efficiency_pct": 70.5, "comparative_hot_water_efficiency_pct": 49.6, "output_kw_max": 24.0, "final_year_of_manufacture": 2010, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008108", "000031", "0", "2010/Jan/28 08:47", "Vaillant", "Vaillant", "Turbomax Plus", "824E", "VUW GB 242 - 5E", "2000", "2010", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "24.0", "24.0", "", "", "80.6", "70.5", "", "49.6", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.4", "82.2", "", "", "", "", "82.0"]} +{"pcdb_id": 8109, "brand_name": "Vaillant", "model_name": "Turbomax Plus", "model_qualifier": "828E", "winter_efficiency_pct": 80.6, "summer_efficiency_pct": 70.5, "comparative_hot_water_efficiency_pct": 49.6, "output_kw_max": 28.0, "final_year_of_manufacture": 2010, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008109", "000031", "0", "2010/Jan/28 08:43", "Vaillant", "Vaillant", "Turbomax Plus", "828E", "VUW GB 282 - 5E", "2000", "2010", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "28.0", "28.0", "", "", "80.6", "70.5", "", "49.6", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.5", "82.0", "", "", "", "", "81.9"]} +{"pcdb_id": 8110, "brand_name": "Vaillant", "model_name": "Turbomax Pro", "model_qualifier": "24E", "winter_efficiency_pct": 80.6, "summer_efficiency_pct": 70.5, "comparative_hot_water_efficiency_pct": 49.6, "output_kw_max": 24.0, "final_year_of_manufacture": 2000, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008110", "000031", "0", "2006/Jan/17 12:55", "Vaillant", "Vaillant", "Turbomax Pro", "24E", "VUW GB 242 - 3E", "2000", "2000", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "24.0", "24.0", "", "", "80.6", "70.5", "", "49.6", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.4", "82.2", "", "", "", "", "82.0"]} +{"pcdb_id": 8117, "brand_name": "Halstead", "model_name": "Wickes LW", "model_qualifier": "40Ci", "winter_efficiency_pct": 76.2, "summer_efficiency_pct": 66.1, "comparative_hot_water_efficiency_pct": 48.3, "output_kw_max": 11.72, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008117", "000019", "0", "2012/Mar/27 10:12", "Halstead Boilers", "Halstead", "Wickes LW", "40Ci", "GC No41-333-51", "", "2001", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "8.79", "11.72", "", "", "76.2", "66.1", "", "48.3", "", "2", "", "", "101", "1", "1", "35", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "78.5", "77.1", "", "", "", "", "77.4"]} +{"pcdb_id": 8118, "brand_name": "Halstead", "model_name": "Wickes LW", "model_qualifier": "50Ci", "winter_efficiency_pct": 77.2, "summer_efficiency_pct": 67.1, "comparative_hot_water_efficiency_pct": 49.0, "output_kw_max": 14.65, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008118", "000019", "0", "2012/Mar/27 10:12", "Halstead Boilers", "Halstead", "Wickes LW", "50Ci", "GC No41-333-52", "", "2001", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "11.72", "14.65", "", "", "77.2", "67.1", "", "49.0", "", "2", "", "", "101", "1", "1", "35", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.4", "78.2", "", "", "", "", "78.4"]} +{"pcdb_id": 8119, "brand_name": "Halstead", "model_name": "Wickes LW", "model_qualifier": "60Ci", "winter_efficiency_pct": 76.5, "summer_efficiency_pct": 66.4, "comparative_hot_water_efficiency_pct": 48.5, "output_kw_max": 17.58, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008119", "000019", "0", "2012/Mar/27 10:12", "Halstead Boilers", "Halstead", "Wickes LW", "60Ci", "GC No41-333-53", "", "2001", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "17.58", "17.58", "", "", "76.5", "66.4", "", "48.5", "", "2", "", "", "101", "1", "1", "35", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "78.6", "77.6", "", "", "", "", "77.8"]} +{"pcdb_id": 8120, "brand_name": "Halstead", "model_name": "Wickes", "model_qualifier": "90", "winter_efficiency_pct": 78.2, "summer_efficiency_pct": 68.1, "comparative_hot_water_efficiency_pct": 47.9, "output_kw_max": 23.45, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008120", "000019", "0", "2006/Jan/17 12:55", "Halstead Boilers", "Halstead", "Wickes", "90", "GC No47-333-09", "", "2001", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "23.45", "23.45", "", "", "78.2", "68.1", "", "47.9", "", "2", "", "", "104", "1", "2", "160", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.6", "77.2", "", "", "", "", "78.1"]} +{"pcdb_id": 8121, "brand_name": "Halstead", "model_name": "Best", "model_qualifier": "30", "winter_efficiency_pct": 76.8, "summer_efficiency_pct": 66.7, "comparative_hot_water_efficiency_pct": 48.7, "output_kw_max": 8.79, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008121", "000019", "0", "2012/Mar/27 10:12", "Halstead Boilers", "Halstead", "Best", "30", "GC No41-333-50", "", "2001", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "5.86", "8.79", "", "", "76.8", "66.7", "", "48.7", "", "2", "", "", "101", "1", "1", "35", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.6", "77.2", "", "", "", "", "77.7"]} +{"pcdb_id": 8122, "brand_name": "Halstead", "model_name": "Best", "model_qualifier": "40", "winter_efficiency_pct": 76.5, "summer_efficiency_pct": 66.4, "comparative_hot_water_efficiency_pct": 48.5, "output_kw_max": 11.72, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008122", "000019", "0", "2012/Mar/27 10:12", "Halstead Boilers", "Halstead", "Best", "40", "GC No41-333-51", "", "2001", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "8.79", "11.72", "", "", "76.5", "66.4", "", "48.5", "", "2", "", "", "101", "1", "1", "35", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.1", "77.1", "", "", "", "", "77.5"]} +{"pcdb_id": 8123, "brand_name": "Halstead", "model_name": "Best", "model_qualifier": "50", "winter_efficiency_pct": 77.3, "summer_efficiency_pct": 67.2, "comparative_hot_water_efficiency_pct": 49.1, "output_kw_max": 14.65, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008123", "000019", "0", "2012/Mar/27 10:12", "Halstead Boilers", "Halstead", "Best", "50", "GC No41-333-52", "", "2001", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "11.72", "14.65", "", "", "77.3", "67.2", "", "49.1", "", "2", "", "", "101", "1", "1", "35", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.6", "78.2", "", "", "", "", "78.5"]} +{"pcdb_id": 8124, "brand_name": "Halstead", "model_name": "Best", "model_qualifier": "60", "winter_efficiency_pct": 76.5, "summer_efficiency_pct": 66.4, "comparative_hot_water_efficiency_pct": 48.5, "output_kw_max": 17.58, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008124", "000019", "0", "2012/Mar/27 10:12", "Halstead Boilers", "Halstead", "Best", "60", "GC No41-333-53", "", "2001", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "17.58", "17.58", "", "", "76.5", "66.4", "", "48.5", "", "2", "", "", "101", "1", "1", "35", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "78.6", "77.6", "", "", "", "", "77.8"]} +{"pcdb_id": 8125, "brand_name": "Halstead", "model_name": "Best", "model_qualifier": "80", "winter_efficiency_pct": 77.1, "summer_efficiency_pct": 67.0, "comparative_hot_water_efficiency_pct": 48.9, "output_kw_max": 23.44, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008125", "000019", "0", "2012/Mar/27 10:12", "Halstead Boilers", "Halstead", "Best", "80", "GC No41-333-56", "", "2001", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "17.57", "23.44", "", "", "77.1", "67.0", "", "48.9", "", "2", "", "", "101", "1", "1", "35", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.2", "78.2", "", "", "", "", "78.4"]} +{"pcdb_id": 8126, "brand_name": "Halstead", "model_name": "Best", "model_qualifier": "40", "winter_efficiency_pct": 78.3, "summer_efficiency_pct": 68.2, "comparative_hot_water_efficiency_pct": 49.8, "output_kw_max": 12.15, "final_year_of_manufacture": 2002, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008126", "000019", "0", "2012/Mar/27 10:12", "Halstead Boilers", "Halstead", "Best", "40", "GC No41-333-54", "", "2002", "2", "2", "1", "1", "0", "", "", "1", "2", "2", "12.15", "12.15", "", "", "78.3", "68.2", "", "49.8", "", "2", "0", "", "101", "1", "1", "35", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "80.9", "78.8", "", "", "", "", "79.2"]} +{"pcdb_id": 8127, "brand_name": "Halstead", "model_name": "Best", "model_qualifier": "60", "winter_efficiency_pct": 77.7, "summer_efficiency_pct": 67.6, "comparative_hot_water_efficiency_pct": 49.4, "output_kw_max": 18.0, "final_year_of_manufacture": 2002, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008127", "000019", "0", "2012/Mar/27 10:12", "Halstead Boilers", "Halstead", "Best", "60", "GC No41-333-55", "", "2002", "2", "2", "1", "1", "0", "", "", "1", "2", "2", "18", "18", "", "", "77.7", "67.6", "", "49.4", "", "2", "0", "", "101", "1", "1", "35", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.9", "78.7", "", "", "", "", "79.0"]} +{"pcdb_id": 8128, "brand_name": "Halstead", "model_name": "Finest", "model_qualifier": "", "winter_efficiency_pct": 78.2, "summer_efficiency_pct": 68.1, "comparative_hot_water_efficiency_pct": 47.9, "output_kw_max": 23.45, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008128", "000019", "0", "2010/Sep/30 11:12", "Halstead Boilers", "Halstead", "Finest", "", "GC No47-333-06", "", "2001", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "23.45", "23.45", "", "", "78.2", "68.1", "", "47.9", "", "2", "", "", "104", "1", "2", "160", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.6", "77.2", "", "", "", "", "78.1"]} +{"pcdb_id": 8129, "brand_name": "Halstead", "model_name": "Finest Gold", "model_qualifier": "", "winter_efficiency_pct": 78.2, "summer_efficiency_pct": 68.1, "comparative_hot_water_efficiency_pct": 47.9, "output_kw_max": 23.45, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008129", "000019", "0", "2006/Jan/17 12:55", "Halstead Boilers", "Halstead", "Finest Gold", "", "GC No47-333-07", "", "2001", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "23.45", "23.45", "", "", "78.2", "68.1", "", "47.9", "", "2", "", "", "104", "1", "2", "160", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.6", "77.2", "", "", "", "", "78.1"]} +{"pcdb_id": 8130, "brand_name": "Halstead", "model_name": "Finest", "model_qualifier": "", "winter_efficiency_pct": 78.5, "summer_efficiency_pct": 68.4, "comparative_hot_water_efficiency_pct": 48.1, "output_kw_max": 23.45, "final_year_of_manufacture": 2002, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008130", "000019", "0", "2006/Jan/17 12:55", "Halstead Boilers", "Halstead", "Finest", "", "GC No47-333-08", "", "2002", "2", "2", "1", "2", "0", "", "", "1", "2", "2", "23.45", "23.45", "", "", "78.5", "68.4", "", "48.1", "", "2", "0", "", "104", "1", "2", "160", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.2", "78.2", "", "", "", "", "78.8"]} +{"pcdb_id": 8131, "brand_name": "Vaillant", "model_name": "Ecomax", "model_qualifier": "613E", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 13.5, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008131", "000031", "0", "2012/Mar/27 10:12", "Vaillant", "Vaillant", "Ecomax", "613E", "VU GB 126 E-C", "2000", "2001", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "13.5", "13.5", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "96.6", "", "", "", "", "95.0"]} +{"pcdb_id": 8132, "brand_name": "Malvern", "model_name": "tentwenty", "model_qualifier": "", "winter_efficiency_pct": 84.7, "summer_efficiency_pct": 77.1, "comparative_hot_water_efficiency_pct": 56.3, "output_kw_max": 17.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008132", "000023", "0", "2012/Mar/27 10:12", "Malvern Boilers", "Malvern", "tentwenty", "", "GC No 41.555.17", "2000", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "10.3", "17", "", "", "84.7", "77.1", "", "56.3", "", "2", "", "", "101", "1", "1", "40", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "87.8", "92.1", "", "", "", "", "91.3"]} +{"pcdb_id": 8133, "brand_name": "Malvern", "model_name": "twentytwentysix", "model_qualifier": "", "winter_efficiency_pct": 84.0, "summer_efficiency_pct": 76.4, "comparative_hot_water_efficiency_pct": 55.8, "output_kw_max": 23.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008133", "000023", "0", "2012/Mar/27 10:12", "Malvern Boilers", "Malvern", "twentytwentysix", "", "GC No 41.555.18", "2000", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "20.6", "23.5", "", "", "84.0", "76.4", "", "55.8", "", "2", "", "", "101", "1", "1", "40", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "87.8", "90.2", "", "", "", "", "89.7"]} +{"pcdb_id": 8134, "brand_name": "Alpha", "model_name": "CB24X", "model_qualifier": "", "winter_efficiency_pct": 80.1, "summer_efficiency_pct": 70.0, "comparative_hot_water_efficiency_pct": 49.2, "output_kw_max": 23.3, "final_year_of_manufacture": 2005, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008134", "000001", "0", "2011/Sep/06 13:08", "Alpha Therm", "Alpha", "CB24X", "", "", "2000", "2005", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "23.3", "23.3", "", "", "80.1", "70.0", "", "49.2", "", "2", "", "", "104", "1", "2", "170", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.1", "80.5", "", "", "", "", "80.8"]} +{"pcdb_id": 8135, "brand_name": "Alpha", "model_name": "CB24", "model_qualifier": "", "winter_efficiency_pct": 80.1, "summer_efficiency_pct": 70.0, "comparative_hot_water_efficiency_pct": 49.2, "output_kw_max": 23.3, "final_year_of_manufacture": 2005, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008135", "000001", "0", "2011/Sep/06 13:08", "Alpha Therm", "Alpha", "CB24", "", "", "2000", "2005", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "23.3", "23.3", "", "", "80.1", "70.0", "", "49.2", "", "2", "", "", "104", "1", "2", "170", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.1", "80.5", "", "", "", "", "80.8"]} +{"pcdb_id": 8137, "brand_name": "Alpha", "model_name": "SY24", "model_qualifier": "", "winter_efficiency_pct": 80.3, "summer_efficiency_pct": 69.6, "comparative_hot_water_efficiency_pct": 50.9, "output_kw_max": 23.3, "final_year_of_manufacture": 2006, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008137", "000001", "0", "2012/Mar/27 10:12", "Alpha Therm", "Alpha", "SY24", "", "", "2000", "2006", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "23.3", "23.3", "", "", "80.3", "69.6", "", "50.9", "", "2", "", "", "102", "1", "2", "170", "5", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.1", "80.5", "", "", "", "", "80.8"]} +{"pcdb_id": 8138, "brand_name": "Alpha", "model_name": "CB28", "model_qualifier": "", "winter_efficiency_pct": 81.0, "summer_efficiency_pct": 70.9, "comparative_hot_water_efficiency_pct": 49.8, "output_kw_max": 28.0, "final_year_of_manufacture": 2005, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008138", "000001", "0", "2011/Sep/06 13:08", "Alpha Therm", "Alpha", "CB28", "", "", "2000", "2005", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "28.0", "28.0", "", "", "81.0", "70.9", "", "49.8", "", "2", "", "", "104", "1", "2", "170", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "83.3", "81.5", "", "", "", "", "81.8"]} +{"pcdb_id": 8140, "brand_name": "Powermax", "model_name": "155x", "model_qualifier": "", "winter_efficiency_pct": 84.3, "summer_efficiency_pct": 82.4, "comparative_hot_water_efficiency_pct": 66.4, "output_kw_max": 15.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 3, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008140", "000099", "0", "2002/Aug/14 10:19", "Range Powermax", "Powermax", "155x", "", "87AU97", "1996", "current", "1", "1", "1", "3", "0", "", "", "1", "2", "2", "15.5", "15.5", "", "", "84.3", "82.4", "", "66.4", "", "2", "", "", "107", "1", "1", "140", "0", "3", "", "0", "100", "0", "50", "5", "80", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "83.8", "86.0", "", "", "", "", "85.6"]} +{"pcdb_id": 8147, "brand_name": "Ideal", "model_name": "Concord", "model_qualifier": "CXSD60", "winter_efficiency_pct": 78.7, "summer_efficiency_pct": 68.0, "comparative_hot_water_efficiency_pct": 49.7, "output_kw_max": 60.1, "final_year_of_manufacture": 2002, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008147", "000008", "0", "2012/Mar/27 10:12", "Caradon Plumbing", "Ideal", "Concord", "CXSD60", "P.I.No 87/AQ/103", "", "2002", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "60.1", "60.1", "", "", "78.7", "68.0", "", "49.7", "", "2", "", "", "102", "1", "2", "10", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "80.7", "78.7", "", "", "", "", "79.1"]} +{"pcdb_id": 8148, "brand_name": "Ideal", "model_name": "Concord", "model_qualifier": "CXSD50", "winter_efficiency_pct": 77.2, "summer_efficiency_pct": 66.5, "comparative_hot_water_efficiency_pct": 48.6, "output_kw_max": 50.0, "final_year_of_manufacture": 2002, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008148", "000008", "0", "2012/Mar/27 10:12", "Caradon Plumbing", "Ideal", "Concord", "CXSD50", "P.I.No 87/AQ/103", "", "2002", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "50.0", "50.0", "", "", "77.2", "66.5", "", "48.6", "", "2", "", "", "102", "1", "2", "10", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "79.5", "76.9", "", "", "", "", "77.4"]} +{"pcdb_id": 8149, "brand_name": "Ideal", "model_name": "Concord", "model_qualifier": "CXSD40", "winter_efficiency_pct": 77.2, "summer_efficiency_pct": 66.5, "comparative_hot_water_efficiency_pct": 48.5, "output_kw_max": 42.0, "final_year_of_manufacture": 2002, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008149", "000008", "0", "2012/Mar/27 10:12", "Caradon Plumbing", "Ideal", "Concord", "CXSD40", "P.I.No 87/AQ/103", "", "2002", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "42.0", "42.0", "", "", "77.2", "66.5", "", "48.5", "", "2", "", "", "102", "1", "2", "10", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "79.2", "77.1", "", "", "", "", "77.5"]} +{"pcdb_id": 8156, "brand_name": "Ideal", "model_name": "Concord", "model_qualifier": "CXS60", "winter_efficiency_pct": 78.7, "summer_efficiency_pct": 68.0, "comparative_hot_water_efficiency_pct": 49.7, "output_kw_max": 60.1, "final_year_of_manufacture": 2002, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008156", "000008", "0", "2012/Mar/27 10:12", "Caradon Plumbing", "Ideal", "Concord", "CXS60", "P.I.No 87/AQ/103", "", "2002", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "60.1", "60.1", "", "", "78.7", "68.0", "", "49.7", "", "2", "", "", "102", "1", "2", "10", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "80.7", "78.7", "", "", "", "", "79.1"]} +{"pcdb_id": 8157, "brand_name": "Ideal", "model_name": "Concord", "model_qualifier": "CXS50", "winter_efficiency_pct": 77.2, "summer_efficiency_pct": 66.5, "comparative_hot_water_efficiency_pct": 48.6, "output_kw_max": 50.0, "final_year_of_manufacture": 2002, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008157", "000008", "0", "2012/Mar/27 10:12", "Caradon Plumbing", "Ideal", "Concord", "CXS50", "P.I.No 87/AQ/103", "", "2002", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "50.0", "50.0", "", "", "77.2", "66.5", "", "48.6", "", "2", "", "", "102", "1", "2", "10", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "79.5", "76.9", "", "", "", "", "77.4"]} +{"pcdb_id": 8158, "brand_name": "Ideal", "model_name": "Concord", "model_qualifier": "CXS40", "winter_efficiency_pct": 77.2, "summer_efficiency_pct": 66.5, "comparative_hot_water_efficiency_pct": 48.5, "output_kw_max": 42.0, "final_year_of_manufacture": 2002, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008158", "000008", "0", "2012/Mar/27 10:12", "Caradon Plumbing", "Ideal", "Concord", "CXS40", "P.I.No 87/AQ/103", "", "2002", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "42.0", "42.0", "", "", "77.2", "66.5", "", "48.5", "", "2", "", "", "102", "1", "2", "10", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "79.2", "77.1", "", "", "", "", "77.5"]} +{"pcdb_id": 8165, "brand_name": "Ideal", "model_name": "Concord", "model_qualifier": "CXA60", "winter_efficiency_pct": 78.4, "summer_efficiency_pct": 68.3, "comparative_hot_water_efficiency_pct": 49.9, "output_kw_max": 60.1, "final_year_of_manufacture": 2002, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008165", "000008", "0", "2012/Mar/27 10:12", "Caradon Plumbing", "Ideal", "Concord", "CXA60", "P.I.No 87/AP/80", "", "2002", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "60.1", "60.1", "", "", "78.4", "68.3", "", "49.9", "", "2", "", "", "101", "1", "1", "5", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "80.7", "79.3", "", "", "", "", "79.6"]} +{"pcdb_id": 8166, "brand_name": "Ideal", "model_name": "Concord", "model_qualifier": "CXA50", "winter_efficiency_pct": 77.3, "summer_efficiency_pct": 67.2, "comparative_hot_water_efficiency_pct": 49.1, "output_kw_max": 50.0, "final_year_of_manufacture": 2002, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008166", "000008", "0", "2012/Mar/27 10:12", "Caradon Plumbing", "Ideal", "Concord", "CXA50", "P.I.No 87/AP/80", "", "2002", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "50", "50", "", "", "77.3", "67.2", "", "49.1", "", "2", "", "", "101", "1", "1", "5", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.5", "78.4", "", "", "", "", "78.6"]} +{"pcdb_id": 8167, "brand_name": "Ideal", "model_name": "Concord", "model_qualifier": "CXA40", "winter_efficiency_pct": 76.9, "summer_efficiency_pct": 66.8, "comparative_hot_water_efficiency_pct": 48.8, "output_kw_max": 42.0, "final_year_of_manufacture": 2002, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008167", "000008", "0", "2012/Mar/27 10:12", "Caradon Plumbing", "Ideal", "Concord", "CXA40", "P.I.No 87/AP/80", "", "2002", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "42", "42", "", "", "76.9", "66.8", "", "48.8", "", "2", "", "", "101", "1", "1", "5", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.2", "77.8", "", "", "", "", "78.1"]} +{"pcdb_id": 8175, "brand_name": "Quantum", "model_name": "Q 100 LPG", "model_qualifier": "", "winter_efficiency_pct": 85.6, "summer_efficiency_pct": 78.0, "comparative_hot_water_efficiency_pct": 57.0, "output_kw_max": 33.7, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008175", "000205", "0", "2012/Mar/27 10:12", "Quantum Heating", "Quantum", "Q 100 LPG", "", "", "1999", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "33.7", "33.7", "", "", "85.6", "78.0", "", "57.0", "", "2", "0", "", "101", "1", "1", "80", "80", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "89.0", "91.6", "", "", "", "", "91.1"]} +{"pcdb_id": 8176, "brand_name": "Quantum", "model_name": "Q 80 LPG", "model_qualifier": "", "winter_efficiency_pct": 85.0, "summer_efficiency_pct": 77.4, "comparative_hot_water_efficiency_pct": 56.5, "output_kw_max": 27.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008176", "000205", "0", "2012/Mar/27 10:12", "Quantum Heating", "Quantum", "Q 80 LPG", "", "", "1999", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "27", "27", "", "", "85.0", "77.4", "", "56.5", "", "2", "0", "", "101", "1", "1", "80", "80", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.6", "89.0", "", "", "", "", "89.5"]} +{"pcdb_id": 8177, "brand_name": "Quantum", "model_name": "Q 60 LPG", "model_qualifier": "", "winter_efficiency_pct": 85.3, "summer_efficiency_pct": 77.7, "comparative_hot_water_efficiency_pct": 56.7, "output_kw_max": 20.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008177", "000205", "0", "2012/Mar/27 10:12", "Quantum Heating", "Quantum", "Q 60 LPG", "", "", "1999", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "20.2", "20.2", "", "", "85.3", "77.7", "", "56.7", "", "2", "0", "", "101", "1", "1", "80", "80", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "88.3", "91.1", "", "", "", "", "90.6"]} +{"pcdb_id": 8178, "brand_name": "Quantum", "model_name": "Q50", "model_qualifier": "", "winter_efficiency_pct": 85.6, "summer_efficiency_pct": 78.0, "comparative_hot_water_efficiency_pct": 57.0, "output_kw_max": 16.8, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008178", "000205", "0", "2012/Mar/27 10:12", "Quantum Heating", "Quantum", "Q50", "", "", "1999", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "16.8", "16.8", "", "", "85.6", "78.0", "", "57.0", "", "2", "", "", "101", "1", "1", "80", "80", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "92.8", "92.3", "", "", "", "", "92.4"]} +{"pcdb_id": 8179, "brand_name": "Viessmann", "model_name": "Vitodens 100", "model_qualifier": "WB10", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 24.0, "final_year_of_manufacture": 2005, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008179", "000033", "0", "2012/Mar/27 10:12", "Viessmann", "Viessmann", "Vitodens 100", "WB10", "", "1999", "2005", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24", "24", "", "", "88.8", "79.8", "", "58.3", "", "2", "", "", "102", "1", "2", "50", "10", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "98.8", "", "", "", "", "96.7"]} +{"pcdb_id": 8180, "brand_name": "Viessmann", "model_name": "Vitodens 100", "model_qualifier": "WB14", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 56.4, "output_kw_max": 24.0, "final_year_of_manufacture": 2005, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008180", "000033", "0", "2006/Jan/17 12:55", "Viessmann", "Viessmann", "Vitodens 100", "WB14", "", "1999", "2005", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "88.8", "80.2", "", "56.4", "", "2", "", "", "104", "1", "2", "50", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "98.8", "", "", "", "", "96.7"]} +{"pcdb_id": 8182, "brand_name": "Worcester", "model_name": "24CDi", "model_qualifier": "RSF Serial ASB", "winter_efficiency_pct": 79.0, "summer_efficiency_pct": 68.9, "comparative_hot_water_efficiency_pct": 48.5, "output_kw_max": 24.0, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008182", "000035", "0", "2002/Jul/29 15:33", "Worcester Heat Systems", "Worcester", "24CDi", "RSF Serial ASB", "47 311 30", "1997", "2001", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "24", "24", "", "", "79.0", "68.9", "", "48.5", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.4", "78.1", "", "", "", "", "78.9"]} +{"pcdb_id": 8183, "brand_name": "Worcester", "model_name": "24CDi", "model_qualifier": "RSF Serial ASC", "winter_efficiency_pct": 81.4, "summer_efficiency_pct": 71.3, "comparative_hot_water_efficiency_pct": 50.2, "output_kw_max": 24.0, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008183", "000035", "0", "2002/Feb/26 12:02", "Worcester Heat Systems", "Worcester", "24CDi", "RSF Serial ASC", "47 311 31", "1997", "2001", "2", "2", "1", "2", "0", "", "", "1", "2", "2", "24", "24", "", "", "81.4", "71.3", "", "50.2", "", "2", "0", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "84.8", "80.5", "", "", "", "", "81.3"]} +{"pcdb_id": 8184, "brand_name": "Halstead", "model_name": "Ace", "model_qualifier": "", "winter_efficiency_pct": 77.1, "summer_efficiency_pct": 67.0, "comparative_hot_water_efficiency_pct": 47.1, "output_kw_max": 24.0, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008184", "000019", "0", "2006/Jan/17 12:55", "Halstead Boilers", "Halstead", "Ace", "", "Gc No 47 333 10", "", "2001", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "24", "24", "", "", "77.1", "67.0", "", "47.1", "", "2", "", "", "104", "1", "2", "140", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "80.1", "76.4", "", "", "", "", "77.1"]} +{"pcdb_id": 8185, "brand_name": "Grant", "model_name": "Euroflame", "model_qualifier": "Kitchen / Utility 70-90", "winter_efficiency_pct": 85.8, "summer_efficiency_pct": 74.1, "comparative_hot_water_efficiency_pct": 54.1, "output_kw_max": 26.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008185", "000048", "0", "2012/Mar/27 10:12", "Grant Engineering", "Grant", "Euroflame", "Kitchen / Utility 70-90", "", "1993", "current", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "20.5", "26.4", "", "", "85.8", "74.1", "", "54.1", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.3", "86.3", "", "", "", "", "86.1"]} +{"pcdb_id": 8186, "brand_name": "Grant", "model_name": "Euroflame", "model_qualifier": "Boilerhouse 70-90", "winter_efficiency_pct": 85.8, "summer_efficiency_pct": 74.1, "comparative_hot_water_efficiency_pct": 54.1, "output_kw_max": 26.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008186", "000048", "0", "2012/Mar/27 10:12", "Grant Engineering", "Grant", "Euroflame", "Boilerhouse 70-90", "", "1993", "current", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "20.5", "26.4", "", "", "85.8", "74.1", "", "54.1", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.3", "86.3", "", "", "", "", "86.1"]} +{"pcdb_id": 8187, "brand_name": "Grant", "model_name": "Euroflame", "model_qualifier": "Outdoor Module 70-90", "winter_efficiency_pct": 85.8, "summer_efficiency_pct": 74.1, "comparative_hot_water_efficiency_pct": 54.1, "output_kw_max": 26.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008187", "000048", "0", "2012/Mar/27 10:12", "Grant Engineering", "Grant", "Euroflame", "Outdoor Module 70-90", "", "1993", "current", "4", "1", "2", "1", "0", "", "", "1", "1", "2", "20.5", "26.4", "", "", "85.8", "74.1", "", "54.1", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.3", "86.3", "", "", "", "", "86.1"]} +{"pcdb_id": 8188, "brand_name": "Grant", "model_name": "Euroflame", "model_qualifier": "Boilerhouse 50-70", "winter_efficiency_pct": 85.8, "summer_efficiency_pct": 74.1, "comparative_hot_water_efficiency_pct": 54.1, "output_kw_max": 20.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008188", "000048", "0", "2012/Mar/27 10:12", "Grant Engineering", "Grant", "Euroflame", "Boilerhouse 50-70", "", "1996", "current", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "14.6", "20.5", "", "", "85.8", "74.1", "", "54.1", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.3", "86.3", "", "", "", "", "86.1"]} +{"pcdb_id": 8189, "brand_name": "Grant", "model_name": "Euroflame", "model_qualifier": "Kitchen / Utility 50-70", "winter_efficiency_pct": 85.8, "summer_efficiency_pct": 74.1, "comparative_hot_water_efficiency_pct": 54.1, "output_kw_max": 20.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008189", "000048", "0", "2012/Mar/27 10:12", "Grant Engineering", "Grant", "Euroflame", "Kitchen / Utility 50-70", "", "1997", "current", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "14.65", "20.5", "", "", "85.8", "74.1", "", "54.1", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.3", "86.3", "", "", "", "", "86.1"]} +{"pcdb_id": 8190, "brand_name": "Grant", "model_name": "Euroflame", "model_qualifier": "Outdoor Module 50-70", "winter_efficiency_pct": 85.8, "summer_efficiency_pct": 74.1, "comparative_hot_water_efficiency_pct": 54.1, "output_kw_max": 20.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008190", "000048", "0", "2012/Mar/27 10:12", "Grant Engineering", "Grant", "Euroflame", "Outdoor Module 50-70", "", "1996", "current", "4", "1", "2", "1", "0", "", "", "1", "1", "2", "14.65", "20.5", "", "", "85.8", "74.1", "", "54.1", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.3", "86.3", "", "", "", "", "86.1"]} +{"pcdb_id": 8191, "brand_name": "Grant", "model_name": "Euroflame", "model_qualifier": "System 50-90", "winter_efficiency_pct": 85.8, "summer_efficiency_pct": 74.1, "comparative_hot_water_efficiency_pct": 54.1, "output_kw_max": 26.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008191", "000048", "0", "2012/Mar/27 10:12", "Grant Engineering", "Grant", "Euroflame", "System 50-90", "", "1998", "current", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "14.65", "26.4", "", "", "85.8", "74.1", "", "54.1", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.3", "86.3", "", "", "", "", "86.1"]} +{"pcdb_id": 8192, "brand_name": "Grant", "model_name": "Combi", "model_qualifier": "70 Mk II", "winter_efficiency_pct": 84.0, "summer_efficiency_pct": 74.5, "comparative_hot_water_efficiency_pct": 52.4, "output_kw_max": 20.52, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008192", "000048", "0", "2001/Jun/19 15:49", "Grant Engineering", "Grant", "Combi", "70 Mk II", "", "1997", "current", "4", "1", "1", "2", "0", "", "", "1", "2", "2", "20.52", "20.52", "", "", "84.0", "74.5", "", "52.4", "", "2", "", "", "202", "1", "1", "", "", "0", "", "", "0", "0", "25", "3", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.3", "86.3", "", "", "", "", "86.1"]} +{"pcdb_id": 8193, "brand_name": "Grant", "model_name": "Combi", "model_qualifier": "90 Mk II", "winter_efficiency_pct": 84.9, "summer_efficiency_pct": 75.4, "comparative_hot_water_efficiency_pct": 53.0, "output_kw_max": 26.37, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008193", "000048", "0", "2001/Jun/19 15:48", "Grant Engineering", "Grant", "Combi", "90 Mk II", "", "1995", "current", "4", "1", "1", "2", "0", "", "", "1", "2", "2", "26.37", "26.37", "", "", "84.9", "75.4", "", "53.0", "", "2", "", "", "202", "1", "1", "", "", "0", "", "", "0", "0", "25", "3", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.4", "88.0", "", "", "", "", "87.7"]} +{"pcdb_id": 8194, "brand_name": "Grant", "model_name": "Multipass", "model_qualifier": "Boilerhouse 70-90", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 26.37, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008194", "000048", "0", "2012/Mar/27 10:12", "Grant Engineering", "Grant", "Multipass", "Boilerhouse 70-90", "", "1994", "current", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "20.52", "26.37", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "89.8", "87.3", "", "", "", "", "87.8"]} +{"pcdb_id": 8195, "brand_name": "Grant", "model_name": "Multipass", "model_qualifier": "Boilerhouse 90-110", "winter_efficiency_pct": 86.5, "summer_efficiency_pct": 74.8, "comparative_hot_water_efficiency_pct": 54.6, "output_kw_max": 32.24, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008195", "000048", "0", "2012/Mar/27 10:12", "Grant Engineering", "Grant", "Multipass", "Boilerhouse 90-110", "", "1994", "current", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "26.37", "32.24", "", "", "86.5", "74.8", "", "54.6", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "91.1", "86.8", "", "", "", "", "87.6"]} +{"pcdb_id": 8196, "brand_name": "Grant", "model_name": "Multipass", "model_qualifier": "Boilerhouse 110-140", "winter_efficiency_pct": 86.5, "summer_efficiency_pct": 74.8, "comparative_hot_water_efficiency_pct": 54.6, "output_kw_max": 41.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008196", "000048", "0", "2012/Mar/27 10:12", "Grant Engineering", "Grant", "Multipass", "Boilerhouse 110-140", "", "1994", "current", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "32.24", "41.0", "", "", "86.5", "74.8", "", "54.6", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "91.1", "86.8", "", "", "", "", "87.6"]} +{"pcdb_id": 8197, "brand_name": "Grant", "model_name": "Multipass", "model_qualifier": "Boilerhouse 140-160", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 46.89, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008197", "000048", "0", "2012/Mar/27 10:12", "Grant Engineering", "Grant", "Multipass", "Boilerhouse 140-160", "", "1995", "current", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "41.03", "46.89", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "88.0", "90.9", "", "", "", "", "90.3"]} +{"pcdb_id": 8198, "brand_name": "Grant", "model_name": "Multipass", "model_qualifier": "Boilerhouse 160-200", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 58.62, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008198", "000048", "0", "2012/Mar/27 10:12", "Grant Engineering", "Grant", "Multipass", "Boilerhouse 160-200", "", "1995", "current", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "46.89", "58.62", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "90.1", "93.5", "", "", "", "", "92.9"]} +{"pcdb_id": 8199, "brand_name": "Grant", "model_name": "Multipass", "model_qualifier": "Kitchen 50-70", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 20.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008199", "000048", "0", "2012/Mar/27 10:12", "Grant Engineering", "Grant", "Multipass", "Kitchen 50-70", "", "1994", "current", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "14.6", "20.5", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "90.0", "87.6", "", "", "", "", "88.1"]} +{"pcdb_id": 8200, "brand_name": "Grant", "model_name": "Multipass", "model_qualifier": "Kitchen 70-90", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 26.37, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008200", "000048", "0", "2012/Mar/27 10:12", "Grant Engineering", "Grant", "Multipass", "Kitchen 70-90", "", "1994", "current", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "20.52", "26.37", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "89.8", "87.3", "", "", "", "", "87.8"]} +{"pcdb_id": 8201, "brand_name": "Grant", "model_name": "Multipass", "model_qualifier": "Kitchen 90-110", "winter_efficiency_pct": 86.5, "summer_efficiency_pct": 74.8, "comparative_hot_water_efficiency_pct": 54.7, "output_kw_max": 41.03, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008201", "000048", "0", "2012/Mar/27 10:12", "Grant Engineering", "Grant", "Multipass", "Kitchen 90-110", "", "1995", "current", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "26.37", "41.03", "", "", "86.5", "74.8", "", "54.7", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.9", "86.9", "", "", "", "", "87.1"]} +{"pcdb_id": 8202, "brand_name": "Grant", "model_name": "Multipass", "model_qualifier": "Kitchen 110-140", "winter_efficiency_pct": 86.5, "summer_efficiency_pct": 74.8, "comparative_hot_water_efficiency_pct": 54.6, "output_kw_max": 41.03, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008202", "000048", "0", "2012/Mar/27 10:12", "Grant Engineering", "Grant", "Multipass", "Kitchen 110-140", "", "1995", "current", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "32.24", "41.03", "", "", "86.5", "74.8", "", "54.6", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "91.1", "86.8", "", "", "", "", "87.6"]} +{"pcdb_id": 8203, "brand_name": "Grant", "model_name": "Multipass", "model_qualifier": "Kitchen 140-160", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 46.89, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008203", "000048", "0", "2012/Mar/27 10:12", "Grant Engineering", "Grant", "Multipass", "Kitchen 140-160", "", "1995", "current", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "41.03", "46.89", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "88.0", "90.9", "", "", "", "", "90.3"]} +{"pcdb_id": 8204, "brand_name": "Grant", "model_name": "Multipass", "model_qualifier": "Kitchen 160-200", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 58.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008204", "000048", "0", "2012/Mar/27 10:12", "Grant Engineering", "Grant", "Multipass", "Kitchen 160-200", "", "1995", "current", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "46.9", "58.6", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "93.5", "90.1", "", "", "", "", "90.8"]} +{"pcdb_id": 8205, "brand_name": "Worcester", "model_name": "24 CBi", "model_qualifier": "RSF", "winter_efficiency_pct": 77.8, "summer_efficiency_pct": 67.7, "comparative_hot_water_efficiency_pct": 49.4, "output_kw_max": 23.4, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008205", "000035", "0", "2012/Mar/27 10:12", "Worcester Heat Systems", "Worcester", "24 CBi", "RSF", "41 311 48", "2000", "2001", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "14.7", "23.4", "", "", "77.8", "67.7", "", "49.4", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.8", "76.0", "", "", "", "", "77.3"]} +{"pcdb_id": 8206, "brand_name": "Worcester", "model_name": "15 CBi", "model_qualifier": "RSF", "winter_efficiency_pct": 77.5, "summer_efficiency_pct": 67.4, "comparative_hot_water_efficiency_pct": 49.2, "output_kw_max": 14.7, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008206", "000035", "0", "2012/Mar/27 10:12", "Worcester Heat Systems", "Worcester", "15 CBi", "RSF", "41 311 47", "2000", "2001", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "9.0", "14.7", "", "", "77.5", "67.4", "", "49.2", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.7", "76.4", "", "", "", "", "77.4"]} +{"pcdb_id": 8207, "brand_name": "Halstead", "model_name": "Wickes Ace", "model_qualifier": "", "winter_efficiency_pct": 77.1, "summer_efficiency_pct": 67.0, "comparative_hot_water_efficiency_pct": 47.1, "output_kw_max": 24.0, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008207", "000019", "0", "2006/Jan/17 12:55", "Halstead Boilers", "Halstead", "Wickes Ace", "", "Gc No 47 333 11", "", "2001", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "24", "24", "", "", "77.1", "67.0", "", "47.1", "", "2", "", "", "104", "1", "2", "140", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "80.1", "76.4", "", "", "", "", "77.1"]} +{"pcdb_id": 8208, "brand_name": "Benson Heating", "model_name": "Halstead", "model_qualifier": "Jetstreme 55", "winter_efficiency_pct": 85.3, "summer_efficiency_pct": 73.6, "comparative_hot_water_efficiency_pct": 53.7, "output_kw_max": 16.1, "final_year_of_manufacture": 2003, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008208", "000019", "0", "2012/Mar/27 10:12", "Benson Heating", "Benson Heating", "Halstead", "Jetstreme 55", "08/07/7506-2OFB", "1998", "2003", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "13.2", "16.1", "", "", "85.3", "73.6", "", "53.7", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "88.3", "84.3", "", "", "", "", "85.1"]} +{"pcdb_id": 8209, "brand_name": "Benson Heating", "model_name": "Halstead", "model_qualifier": "Jetstreme 80", "winter_efficiency_pct": 83.8, "summer_efficiency_pct": 72.1, "comparative_hot_water_efficiency_pct": 52.6, "output_kw_max": 23.4, "final_year_of_manufacture": 2003, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008209", "000019", "0", "2012/Mar/27 10:12", "Benson Heating", "Benson Heating", "Halstead", "Jetstreme 80", "06/97/7506OFB", "1997", "2003", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "17.6", "23.4", "", "", "83.8", "72.1", "", "52.6", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "84.7", "82.8", "", "", "", "", "83.2"]} +{"pcdb_id": 8210, "brand_name": "Benson Heating", "model_name": "Halstead", "model_qualifier": "Jetstreme 125", "winter_efficiency_pct": 83.3, "summer_efficiency_pct": 71.6, "comparative_hot_water_efficiency_pct": 52.3, "output_kw_max": 36.6, "final_year_of_manufacture": 2003, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008210", "000019", "0", "2012/Mar/27 10:12", "Benson Heating", "Benson Heating", "Halstead", "Jetstreme 125", "04/98/7506-3OFB", "1998", "2003", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "26.4", "36.6", "", "", "83.3", "71.6", "", "52.3", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "83.0", "83.6", "", "", "", "", "83.5"]} +{"pcdb_id": 8211, "brand_name": "Warmworld", "model_name": "FFC 65/80", "model_qualifier": "", "winter_efficiency_pct": 84.0, "summer_efficiency_pct": 76.4, "comparative_hot_water_efficiency_pct": 55.8, "output_kw_max": 23.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008211", "000034", "0", "2012/Mar/27 10:12", "Warmworld", "Warmworld", "FFC 65/80", "", "GC No 41.555.16", "2000", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "20.6", "23.5", "", "", "84.0", "76.4", "", "55.8", "", "2", "", "", "101", "1", "1", "40", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "87.8", "90.2", "", "", "", "", "89.7"]} +{"pcdb_id": 8212, "brand_name": "Warmworld", "model_name": "FFC 30/60", "model_qualifier": "", "winter_efficiency_pct": 84.7, "summer_efficiency_pct": 77.1, "comparative_hot_water_efficiency_pct": 56.3, "output_kw_max": 17.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008212", "000034", "0", "2012/Mar/27 10:12", "Warmworld", "Warmworld", "FFC 30/60", "", "GC No 41.555.15", "2000", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "10.3", "17.0", "", "", "84.7", "77.1", "", "56.3", "", "2", "", "", "101", "1", "1", "40", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "87.8", "92.1", "", "", "", "", "91.3"]} +{"pcdb_id": 8213, "brand_name": "Ariston", "model_name": "Microgenus 27 MFFI", "model_qualifier": "", "winter_efficiency_pct": 81.1, "summer_efficiency_pct": 71.0, "comparative_hot_water_efficiency_pct": 49.9, "output_kw_max": 27.8, "final_year_of_manufacture": 2007, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008213", "000080", "0", "2007/Sep/12 15:03", "Merloni TermoSanitari SpA", "Ariston", "Microgenus 27 MFFI", "", "GC No. 47-116-15", "1999", "2007", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "27.8", "27.8", "", "", "81.1", "71.0", "", "49.9", "", "2", "", "", "104", "1", "2", "130", "7", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "84.2", "81.7", "", "", "", "", "82.2"]} +{"pcdb_id": 8214, "brand_name": "Ariston", "model_name": "Microgenus 23 MFFI", "model_qualifier": "", "winter_efficiency_pct": 81.3, "summer_efficiency_pct": 71.2, "comparative_hot_water_efficiency_pct": 50.1, "output_kw_max": 23.8, "final_year_of_manufacture": 2007, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008214", "000080", "0", "2007/Sep/12 15:00", "Merloni TermoSanitari SpA", "Ariston", "Microgenus 23 MFFI", "", "GC No. 47-116-14", "1999", "2007", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "23.8", "23.8", "", "", "81.3", "71.2", "", "50.1", "", "2", "", "", "104", "1", "2", "130", "7", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "83.7", "82.1", "", "", "", "", "82.4"]} +{"pcdb_id": 8215, "brand_name": "Ariston", "model_name": "Microcombi 23 MFFI", "model_qualifier": "", "winter_efficiency_pct": 81.0, "summer_efficiency_pct": 70.9, "comparative_hot_water_efficiency_pct": 49.9, "output_kw_max": 23.8, "final_year_of_manufacture": 2007, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008215", "000080", "0", "2007/Jun/18 09:30", "Merloni TermoSanitari SpA", "Ariston", "Microcombi 23 MFFI", "", "GC No. 47-116-16", "2000", "2007", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "23.8", "23.8", "", "", "81.0", "70.9", "", "49.9", "", "2", "", "", "104", "1", "2", "130", "7", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "83.3", "81.5", "", "", "", "", "81.9"]} +{"pcdb_id": 8216, "brand_name": "Ariston", "model_name": "Genus 27 BFFI Plus", "model_qualifier": "", "winter_efficiency_pct": 78.9, "summer_efficiency_pct": 69.8, "comparative_hot_water_efficiency_pct": 36.9, "output_kw_max": 27.4, "final_year_of_manufacture": 2002, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008216", "000080", "0", "2024/Jan/31 10:17", "Merloni TermoSanitari SpA", "Ariston", "Genus 27 BFFI Plus", "", "GC No. 47-116-11", "1997", "2002", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "27.4", "27.4", "", "", "78.9", "69.8", "", "36.9", "", "2", "", "", "106", "1", "2", "200", "7", "2", "2", "0", "52", "0", "15", "2", "62", "60", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.4", "77.6", "", "", "", "", "78.3"]} +{"pcdb_id": 8217, "brand_name": "Ariston", "model_name": "Eurocombi A/27 MFFI", "model_qualifier": "", "winter_efficiency_pct": 79.8, "summer_efficiency_pct": 69.7, "comparative_hot_water_efficiency_pct": 49.0, "output_kw_max": 27.3, "final_year_of_manufacture": 2003, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008217", "000080", "0", "2006/Jan/17 12:55", "Merloni TermoSanitari SpA", "Ariston", "Eurocombi A/27 MFFI", "", "GC No. 47-116-12", "1999", "2003", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "27.3", "27.3", "", "", "79.8", "69.7", "", "49.0", "", "2", "", "", "104", "1", "2", "190", "7", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.5", "79.6", "", "", "", "", "80.1"]} +{"pcdb_id": 8218, "brand_name": "Ariston", "model_name": "Eurocombi A/23 MFFI", "model_qualifier": "", "winter_efficiency_pct": 79.0, "summer_efficiency_pct": 68.9, "comparative_hot_water_efficiency_pct": 48.4, "output_kw_max": 23.1, "final_year_of_manufacture": 2003, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008218", "000080", "0", "2006/Jan/17 12:55", "Merloni TermoSanitari SpA", "Ariston", "Eurocombi A/23 MFFI", "", "GC No. 47-116-10", "1999", "2003", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "23.1", "23.1", "", "", "79.0", "68.9", "", "48.4", "", "2", "", "", "104", "1", "2", "150", "7", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.3", "79.1", "", "", "", "", "79.5"]} +{"pcdb_id": 8219, "brand_name": "Ariston", "model_name": "Genus 30 MFFI", "model_qualifier": "", "winter_efficiency_pct": 80.2, "summer_efficiency_pct": 70.1, "comparative_hot_water_efficiency_pct": 49.3, "output_kw_max": 30.3, "final_year_of_manufacture": 2007, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008219", "000080", "0", "2007/Sep/12 15:08", "Merloni TermoSanitari SpA", "Ariston", "Genus 30 MFFI", "", "GC No. 47-116-13", "1999", "2007", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "30.3", "30.3", "", "", "80.2", "70.1", "", "49.3", "", "2", "", "", "104", "1", "2", "190", "7", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.9", "79.8", "", "", "", "", "80.4"]} +{"pcdb_id": 8220, "brand_name": "Ariston", "model_name": "Microsystem 10 RFFI", "model_qualifier": "", "winter_efficiency_pct": 79.1, "summer_efficiency_pct": 69.0, "comparative_hot_water_efficiency_pct": 50.4, "output_kw_max": 10.4, "final_year_of_manufacture": 2007, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008220", "000080", "0", "2012/Mar/27 10:12", "Merloni TermoSanitari SpA", "Ariston", "Microsystem 10 RFFI", "", "GC No. 41-116-04", "2000", "2007", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "10.4", "10.4", "", "", "79.1", "69.0", "", "50.4", "", "2", "", "", "101", "1", "1", "155", "7", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.7", "79.6", "", "", "", "", "80.0"]} +{"pcdb_id": 8221, "brand_name": "Ariston", "model_name": "Microsystem 15 RFFI", "model_qualifier": "", "winter_efficiency_pct": 80.9, "summer_efficiency_pct": 70.8, "comparative_hot_water_efficiency_pct": 51.7, "output_kw_max": 13.8, "final_year_of_manufacture": 2007, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008221", "000080", "0", "2012/Mar/27 10:12", "Merloni TermoSanitari SpA", "Ariston", "Microsystem 15 RFFI", "", "GC No. 41-116-05", "2000", "2007", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "13.8", "13.8", "", "", "80.9", "70.8", "", "51.7", "", "2", "", "", "101", "1", "1", "155", "7", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.8", "82.2", "", "", "", "", "82.3"]} +{"pcdb_id": 8222, "brand_name": "Ariston", "model_name": "Microsystem 21 RFFI", "model_qualifier": "", "winter_efficiency_pct": 81.4, "summer_efficiency_pct": 70.7, "comparative_hot_water_efficiency_pct": 51.6, "output_kw_max": 21.0, "final_year_of_manufacture": 2007, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008222", "000080", "0", "2012/Mar/27 10:12", "Merloni TermoSanitari SpA", "Ariston", "Microsystem 21 RFFI", "", "GC No. 41-116-06", "2000", "2007", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "21.0", "21.0", "", "", "81.4", "70.7", "", "51.6", "", "2", "", "", "102", "1", "2", "155", "7", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "83.6", "81.8", "", "", "", "", "82.2"]} +{"pcdb_id": 8223, "brand_name": "Ariston", "model_name": "Ecogenus 24 MFFI", "model_qualifier": "", "winter_efficiency_pct": 86.6, "summer_efficiency_pct": 78.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 24.5, "final_year_of_manufacture": 2002, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008223", "000080", "0", "2006/Jan/17 12:55", "Merloni TermoSanitari SpA", "Ariston", "Ecogenus 24 MFFI", "", "GC No. 47-116-17", "2000", "2002", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.5", "24.5", "", "", "86.6", "78.0", "", "54.8", "", "2", "", "", "104", "1", "2", "130", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.7", "93.3", "", "", "", "", "92.3"]} +{"pcdb_id": 8224, "brand_name": "Ariston", "model_name": "Ecogenus 24 RFFI System", "model_qualifier": "", "winter_efficiency_pct": 86.6, "summer_efficiency_pct": 77.6, "comparative_hot_water_efficiency_pct": 56.7, "output_kw_max": 24.5, "final_year_of_manufacture": 2002, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008224", "000080", "0", "2012/Mar/27 10:12", "Merloni TermoSanitari SpA", "Ariston", "Ecogenus 24 RFFI System", "", "GC No. 41-116-03", "2000", "2002", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24.5", "24.5", "", "", "86.6", "77.6", "", "56.7", "", "2", "", "", "102", "1", "2", "130", "7", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.7", "93.3", "", "", "", "", "92.3"]} +{"pcdb_id": 8225, "brand_name": "Ariston", "model_name": "Genus 27 RFFI System", "model_qualifier": "", "winter_efficiency_pct": 80.0, "summer_efficiency_pct": 69.3, "comparative_hot_water_efficiency_pct": 50.7, "output_kw_max": 27.3, "final_year_of_manufacture": 2007, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008225", "000080", "0", "2012/Mar/27 10:12", "Merloni TermoSanitari SpA", "Ariston", "Genus 27 RFFI System", "", "GC No. 41-116-01", "1998", "2007", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "27.3", "27.3", "", "", "80.0", "69.3", "", "50.7", "", "2", "", "", "102", "1", "2", "149", "7", "0", "", "0", "0", "0", "0", "", "0", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.5", "79.6", "", "", "", "", "80.1"]} +{"pcdb_id": 8226, "brand_name": "Worcester", "model_name": "Danesmoor WM 12/19", "model_qualifier": "RS", "winter_efficiency_pct": 85.2, "summer_efficiency_pct": 73.5, "comparative_hot_water_efficiency_pct": 53.7, "output_kw_max": 19.0, "final_year_of_manufacture": 2002, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008226", "000035", "0", "2020/Sep/02 14:14", "Worcester Heat Systems", "Worcester", "Danesmoor WM 12/19", "RS", "C15661/1", "2000", "2002", "4", "2", "2", "1", "0", "", "", "1", "2", "1", "12", "19.0", "", "", "85.2", "73.5", "", "53.7", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "84.4", "86.0", "", "", "", "", "85.7"]} +{"pcdb_id": 8227, "brand_name": "Ferroli", "model_name": "Modena 102", "model_qualifier": "", "winter_efficiency_pct": 78.9, "summer_efficiency_pct": 68.8, "comparative_hot_water_efficiency_pct": 48.4, "output_kw_max": 30.0, "final_year_of_manufacture": 2005, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008227", "000097", "0", "2009/Apr/28 16:13", "Ferroli", "Ferroli", "Modena 102", "", "", "1999", "2005", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "30.0", "30.0", "", "", "78.9", "68.8", "", "48.4", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.5", "78.7", "", "", "", "", "79.2"]} +{"pcdb_id": 8228, "brand_name": "Ferroli", "model_name": "Arena 30 A", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 32.4, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008228", "000097", "0", "2012/Mar/27 10:12", "Ferroli SpA", "Ferroli", "Arena 30 A", "", "", "2000", "2001", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "32.4", "32.4", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.5", "97.0", "", "", "", "", "95.2"]} +{"pcdb_id": 8229, "brand_name": "Ferroli", "model_name": "Arena 30 C", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 55.8, "output_kw_max": 32.4, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008229", "000097", "0", "2006/Jan/17 12:55", "Ferroli SpA", "Ferroli", "Arena 30 C", "", "", "2000", "2001", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "32.4", "32.4", "", "", "88.0", "79.4", "", "55.8", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.5", "97.0", "", "", "", "", "95.2"]} +{"pcdb_id": 8230, "brand_name": "Servowarm", "model_name": "Elite 21 Plus", "model_qualifier": "", "winter_efficiency_pct": 84.7, "summer_efficiency_pct": 77.1, "comparative_hot_water_efficiency_pct": 56.3, "output_kw_max": 17.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008230", "000091", "0", "2012/Mar/27 10:12", "Malvern Boilers", "Servowarm", "Elite 21 Plus", "", "GC No 41.555.13", "2000", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "10.3", "17", "", "", "84.7", "77.1", "", "56.3", "", "2", "", "", "101", "1", "1", "40", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "87.8", "92.1", "", "", "", "", "91.3"]} +{"pcdb_id": 8231, "brand_name": "Servowarm", "model_name": "Elite 21", "model_qualifier": "", "winter_efficiency_pct": 84.0, "summer_efficiency_pct": 76.4, "comparative_hot_water_efficiency_pct": 55.8, "output_kw_max": 23.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008231", "000091", "0", "2012/Mar/27 10:12", "Malvern Boilers", "Servowarm", "Elite 21", "", "GC No 41.555.14", "2000", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "20.6", "23.5", "", "", "84.0", "76.4", "", "55.8", "", "2", "", "", "101", "1", "1", "40", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "87.8", "90.2", "", "", "", "", "89.7"]} +{"pcdb_id": 8232, "brand_name": "Keston", "model_name": "Celsius", "model_qualifier": "25", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 25.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008232", "000022", "0", "2012/Mar/27 10:12", "Keston Boilers", "Keston", "Celsius", "25", "Celsius 25", "2000", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "25.0", "25.0", "", "", "88.2", "79.2", "", "57.8", "", "2", "", "", "102", "1", "2", "0", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.5", "97.0", "", "", "", "", "95.4"]} +{"pcdb_id": 8233, "brand_name": "Eco Hometec (UK)", "model_name": "Multi-Oil", "model_qualifier": "Type 4", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 78.9, "comparative_hot_water_efficiency_pct": 57.6, "output_kw_max": 20.0, "final_year_of_manufacture": 2005, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008233", "000014", "0", "2012/Mar/27 10:12", "VTH-AG", "Eco Hometec (UK)", "Multi-Oil", "Type 4", "", "1998", "2005", "4", "2", "1", "1", "0", "", "", "2", "2", "2", "20", "20", "", "", "86.7", "78.9", "", "57.6", "", "2", "", "", "201", "1", "2", "60", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "91.1", "91.3", "", "", "", "", "91.2"]} +{"pcdb_id": 8234, "brand_name": "Eco Hometec (UK)", "model_name": "Multi-Oil", "model_qualifier": "Type 2.1", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 78.9, "comparative_hot_water_efficiency_pct": 57.6, "output_kw_max": 20.0, "final_year_of_manufacture": 2005, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008234", "000014", "0", "2012/Mar/27 10:12", "VTH-AG", "Eco Hometec (UK)", "Multi-Oil", "Type 2.1", "", "1998", "2005", "4", "2", "1", "1", "0", "", "", "2", "2", "2", "10", "20", "", "", "86.7", "78.9", "", "57.6", "", "2", "", "", "201", "1", "1", "60", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.1", "91.3", "", "", "", "", "91.2"]} +{"pcdb_id": 8239, "brand_name": "Biasi", "model_name": "24S", "model_qualifier": "", "winter_efficiency_pct": 79.2, "summer_efficiency_pct": 69.1, "comparative_hot_water_efficiency_pct": 48.6, "output_kw_max": 24.0, "final_year_of_manufacture": 2002, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008239", "000208", "0", "2006/Jan/17 12:55", "Biasi (UK)", "Biasi", "24S", "", "47-970-06", "1998", "2002", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "24", "24", "", "", "79.2", "69.1", "", "48.6", "", "2", "", "", "104", "1", "2", "170", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.7", "79.0", "", "", "", "", "79.5"]} +{"pcdb_id": 8240, "brand_name": "Biasi", "model_name": "24SR", "model_qualifier": "", "winter_efficiency_pct": 79.4, "summer_efficiency_pct": 68.7, "comparative_hot_water_efficiency_pct": 50.2, "output_kw_max": 24.0, "final_year_of_manufacture": 2002, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008240", "000208", "0", "2012/Mar/27 10:12", "Biasi (UK)", "Biasi", "24SR", "", "41-970-03", "1998", "2002", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "24", "24", "", "", "79.4", "68.7", "", "50.2", "", "2", "", "", "102", "1", "2", "170", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.7", "79.0", "", "", "", "", "79.5"]} +{"pcdb_id": 8241, "brand_name": "Biasi", "model_name": "28S", "model_qualifier": "", "winter_efficiency_pct": 79.4, "summer_efficiency_pct": 69.3, "comparative_hot_water_efficiency_pct": 48.8, "output_kw_max": 28.0, "final_year_of_manufacture": 2002, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008241", "000208", "0", "2006/Jan/17 12:55", "Biasi (UK)", "Biasi", "28S", "", "47-970-07", "1998", "2002", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "28", "28", "", "", "79.4", "69.3", "", "48.8", "", "2", "", "", "104", "1", "2", "170", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.3", "79.0", "", "", "", "", "79.6"]} +{"pcdb_id": 8242, "brand_name": "Biasi", "model_name": "Savio Gaia", "model_qualifier": "424S", "winter_efficiency_pct": 79.2, "summer_efficiency_pct": 69.1, "comparative_hot_water_efficiency_pct": 48.6, "output_kw_max": 24.0, "final_year_of_manufacture": 2002, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008242", "000208", "0", "2006/Jan/17 12:55", "Biasi (UK)", "Biasi", "Savio Gaia", "424S", "47-970-08", "1997", "2002", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "24", "24", "", "", "79.2", "69.1", "", "48.6", "", "2", "", "", "104", "1", "2", "150", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.7", "79.0", "", "", "", "", "79.5"]} +{"pcdb_id": 8243, "brand_name": "Biasi", "model_name": "Savio Gaia", "model_qualifier": "428S", "winter_efficiency_pct": 79.4, "summer_efficiency_pct": 69.3, "comparative_hot_water_efficiency_pct": 48.8, "output_kw_max": 28.0, "final_year_of_manufacture": 2002, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008243", "000208", "0", "2006/Jan/17 12:55", "Biasi (UK)", "Biasi", "Savio Gaia", "428S", "47-970-09", "1997", "2002", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "28", "28", "", "", "79.4", "69.3", "", "48.8", "", "2", "", "", "104", "1", "2", "170", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.3", "79.0", "", "", "", "", "79.6"]} +{"pcdb_id": 8244, "brand_name": "Biasi", "model_name": "Savio Knightsbridge", "model_qualifier": "424S", "winter_efficiency_pct": 79.2, "summer_efficiency_pct": 69.1, "comparative_hot_water_efficiency_pct": 48.6, "output_kw_max": 24.0, "final_year_of_manufacture": 2002, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008244", "000208", "0", "2006/Jan/17 12:55", "Biasi (UK)", "Biasi", "Savio Knightsbridge", "424S", "47-970-08", "1998", "2002", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "24", "24", "", "", "79.2", "69.1", "", "48.6", "", "2", "", "", "104", "1", "2", "150", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.7", "79.0", "", "", "", "", "79.5"]} +{"pcdb_id": 8245, "brand_name": "Biasi", "model_name": "Savio Knightsbridge", "model_qualifier": "428S", "winter_efficiency_pct": 79.4, "summer_efficiency_pct": 69.3, "comparative_hot_water_efficiency_pct": 48.8, "output_kw_max": 28.0, "final_year_of_manufacture": 2002, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008245", "000208", "0", "2006/Jan/17 12:55", "Biasi (UK)", "Biasi", "Savio Knightsbridge", "428S", "47-970-09", "1998", "2002", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "28", "28", "", "", "79.4", "69.3", "", "48.8", "", "2", "", "", "104", "1", "2", "170", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.3", "79.0", "", "", "", "", "79.6"]} +{"pcdb_id": 8258, "brand_name": "Biasi", "model_name": "Riva", "model_qualifier": "24S", "winter_efficiency_pct": 79.2, "summer_efficiency_pct": 69.1, "comparative_hot_water_efficiency_pct": 48.6, "output_kw_max": 24.0, "final_year_of_manufacture": 2003, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008258", "000208", "0", "2006/Jan/17 12:55", "Biasi (UK)", "Biasi", "Riva", "24S", "47-970-10", "1999", "2003", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "24", "24", "", "", "79.2", "69.1", "", "48.6", "", "2", "", "", "104", "1", "2", "150", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.7", "79.0", "", "", "", "", "79.5"]} +{"pcdb_id": 8259, "brand_name": "Biasi", "model_name": "Riva", "model_qualifier": "24SR", "winter_efficiency_pct": 79.4, "summer_efficiency_pct": 68.7, "comparative_hot_water_efficiency_pct": 50.2, "output_kw_max": 24.0, "final_year_of_manufacture": 2003, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008259", "000208", "0", "2012/Mar/27 10:12", "Biasi (UK)", "Biasi", "Riva", "24SR", "41-970-05", "1999", "2003", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "24", "24", "", "", "79.4", "68.7", "", "50.2", "", "2", "", "", "102", "1", "2", "150", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.7", "79.0", "", "", "", "", "79.5"]} +{"pcdb_id": 8260, "brand_name": "Biasi", "model_name": "Riva", "model_qualifier": "28S", "winter_efficiency_pct": 79.4, "summer_efficiency_pct": 69.3, "comparative_hot_water_efficiency_pct": 48.8, "output_kw_max": 28.0, "final_year_of_manufacture": 2003, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008260", "000208", "0", "2006/Jan/17 12:55", "Biasi (UK)", "Biasi", "Riva", "28S", "47-970-11", "1999", "2003", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "28", "28", "", "", "79.4", "69.3", "", "48.8", "", "2", "", "", "104", "1", "2", "170", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.3", "79.0", "", "", "", "", "79.6"]} +{"pcdb_id": 8261, "brand_name": "Vokera", "model_name": "Linea Plus AG", "model_qualifier": "", "winter_efficiency_pct": 82.1, "summer_efficiency_pct": 72.0, "comparative_hot_water_efficiency_pct": 50.6, "output_kw_max": 32.0, "final_year_of_manufacture": 2010, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008261", "000011", "0", "2010/Oct/21 11:10", "Vokera", "Vokera", "Linea Plus AG", "", "47-094-31", "2000", "2010", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "32", "32", "", "", "82.1", "72.0", "", "50.6", "", "2", "", "", "104", "1", "2", "160", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.4", "84.1", "", "", "", "", "83.8"]} +{"pcdb_id": 8262, "brand_name": "Vokera", "model_name": "Linea", "model_qualifier": "Plus AG", "winter_efficiency_pct": 83.1, "summer_efficiency_pct": 73.0, "comparative_hot_water_efficiency_pct": 51.3, "output_kw_max": 32.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008262", "000011", "0", "2006/Jan/17 12:31", "Vokera", "Vokera", "Linea", "Plus AG", "49BL3161", "1999", "current", "2", "2", "1", "2", "0", "", "", "1", "2", "2", "32", "32", "", "", "83.1", "73.0", "", "51.3", "", "2", "0", "", "104", "1", "2", "0", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "84.9", "86.2", "", "", "", "", "86.0"]} +{"pcdb_id": 8263, "brand_name": "Vokera", "model_name": "Option 24", "model_qualifier": "", "winter_efficiency_pct": 79.3, "summer_efficiency_pct": 69.2, "comparative_hot_water_efficiency_pct": 48.6, "output_kw_max": 23.7, "final_year_of_manufacture": 2010, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008263", "000011", "0", "2010/Oct/21 11:23", "Vokera", "Vokera", "Option 24", "", "47-094-32", "2000", "2010", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "23.7", "23.7", "", "", "79.3", "69.2", "", "48.6", "", "2", "", "", "104", "1", "2", "125", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.0", "78.9", "", "", "", "", "79.5"]} +{"pcdb_id": 8265, "brand_name": "Vokera", "model_name": "Mynute 10e", "model_qualifier": "", "winter_efficiency_pct": 77.9, "summer_efficiency_pct": 67.8, "comparative_hot_water_efficiency_pct": 49.5, "output_kw_max": 11.5, "final_year_of_manufacture": 2002, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008265", "000011", "0", "2012/Mar/27 10:12", "Vokera", "Vokera", "Mynute 10e", "", "41-094-15", "2000", "2002", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "6", "11.5", "", "", "77.9", "67.8", "", "49.5", "", "2", "", "", "101", "1", "1", "125", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.3", "77.8", "", "", "", "", "78.4"]} +{"pcdb_id": 8267, "brand_name": "Vokera", "model_name": "Mynute 14e", "model_qualifier": "", "winter_efficiency_pct": 80.0, "summer_efficiency_pct": 69.9, "comparative_hot_water_efficiency_pct": 51.0, "output_kw_max": 15.4, "final_year_of_manufacture": 2010, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008267", "000011", "0", "2012/Mar/27 10:12", "Vokera", "Vokera", "Mynute 14e", "", "41-094-16", "2000", "2010", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "8.4", "15.40", "", "", "80.0", "69.9", "", "51.0", "", "2", "", "", "101", "1", "1", "125", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "83.2", "80.3", "", "", "", "", "80.8"]} +{"pcdb_id": 8269, "brand_name": "Vokera", "model_name": "Mynute 20e", "model_qualifier": "", "winter_efficiency_pct": 78.9, "summer_efficiency_pct": 68.8, "comparative_hot_water_efficiency_pct": 50.3, "output_kw_max": 19.8, "final_year_of_manufacture": 2010, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008269", "000011", "0", "2012/Mar/27 10:12", "Vokera", "Vokera", "Mynute 20e", "", "41-094-17", "2000", "2010", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "14", "19.8", "", "", "78.9", "68.8", "", "50.3", "", "2", "", "", "101", "1", "1", "125", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.7", "79.4", "", "", "", "", "79.8"]} +{"pcdb_id": 8270, "brand_name": "Vokera", "model_name": "Mynute", "model_qualifier": "Mynute 20e LPG", "winter_efficiency_pct": 82.2, "summer_efficiency_pct": 72.1, "comparative_hot_water_efficiency_pct": 52.7, "output_kw_max": 19.8, "final_year_of_manufacture": 2010, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008270", "000011", "0", "2012/Mar/27 10:12", "Vokera", "Vokera", "Mynute", "Mynute 20e LPG", "4109417", "2000", "2010", "2", "2", "1", "1", "0", "", "", "1", "2", "2", "14", "19.8", "", "", "82.2", "72.1", "", "52.7", "", "2", "0", "", "101", "1", "1", "125", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "84.8", "82.9", "", "", "", "", "83.3"]} +{"pcdb_id": 8271, "brand_name": "Broag Remeha", "model_name": "Quinta", "model_qualifier": "45", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 40.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008271", "000006", "0", "2012/Mar/27 10:12", "Remeha", "Broag Remeha", "Quinta", "45", "0063BL3253", "2000", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "40", "40", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "85", "10", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.6", "97.0", "", "", "", "", "95.2"]} +{"pcdb_id": 8272, "brand_name": "Broag Remeha", "model_name": "Quinta", "model_qualifier": "65", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 61.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008272", "000006", "0", "2012/Mar/27 10:12", "Remeha", "Broag Remeha", "Quinta", "65", "0063BL3253", "2000", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "61", "61", "", "", "88.6", "79.6", "", "58.2", "", "2", "", "", "102", "1", "2", "90", "10", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.6", "98.1", "", "", "", "", "96.3"]} +{"pcdb_id": 8276, "brand_name": "Vaillant", "model_name": "Turbomax Pro", "model_qualifier": "28E", "winter_efficiency_pct": 80.6, "summer_efficiency_pct": 70.5, "comparative_hot_water_efficiency_pct": 49.6, "output_kw_max": 28.0, "final_year_of_manufacture": 2010, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008276", "000031", "0", "2010/Jan/28 08:46", "Vaillant", "Vaillant", "Turbomax Pro", "28E", "VUW GB 282-3", "2000", "2010", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "28.0", "28.0", "", "", "80.6", "70.5", "", "49.6", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.5", "82.0", "", "", "", "", "81.9"]} +{"pcdb_id": 8277, "brand_name": "Vaillant", "model_name": "Thermocompact", "model_qualifier": "628E", "winter_efficiency_pct": 80.8, "summer_efficiency_pct": 70.1, "comparative_hot_water_efficiency_pct": 51.2, "output_kw_max": 28.0, "final_year_of_manufacture": 2010, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008277", "000031", "0", "2012/Mar/27 10:12", "Vaillant", "Vaillant", "Thermocompact", "628E", "VU GB 282-5", "2000", "2010", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "28.0", "28.0", "", "", "80.8", "70.1", "", "51.2", "", "2", "", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.5", "82.0", "", "", "", "", "81.9"]} +{"pcdb_id": 8278, "brand_name": "Vaillant", "model_name": "Thermocompact", "model_qualifier": "624E", "winter_efficiency_pct": 80.8, "summer_efficiency_pct": 70.1, "comparative_hot_water_efficiency_pct": 51.2, "output_kw_max": 24.0, "final_year_of_manufacture": 2010, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008278", "000031", "0", "2012/Mar/27 10:12", "Vaillant", "Vaillant", "Thermocompact", "624E", "VU GB 424-5", "2000", "2010", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "24.0", "24.0", "", "", "80.8", "70.1", "", "51.2", "", "2", "", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.4", "82.2", "", "", "", "", "82.0"]} +{"pcdb_id": 8279, "brand_name": "Vaillant", "model_name": "Thermocompact", "model_qualifier": "620E", "winter_efficiency_pct": 80.7, "summer_efficiency_pct": 70.0, "comparative_hot_water_efficiency_pct": 51.1, "output_kw_max": 20.0, "final_year_of_manufacture": 2010, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008279", "000031", "0", "2012/Mar/27 10:12", "Vaillant", "Vaillant", "Thermocompact", "620E", "VU GB 202-5", "2000", "2010", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "20.0", "20.0", "", "", "80.7", "70.0", "", "51.1", "", "2", "", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.6", "81.8", "", "", "", "", "81.8"]} +{"pcdb_id": 8280, "brand_name": "Vaillant", "model_name": "Thermocompact", "model_qualifier": "615E", "winter_efficiency_pct": 80.0, "summer_efficiency_pct": 69.3, "comparative_hot_water_efficiency_pct": 50.6, "output_kw_max": 15.0, "final_year_of_manufacture": 2010, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008280", "000031", "0", "2012/Mar/27 10:12", "Vaillant", "Vaillant", "Thermocompact", "615E", "VU GB 152-5", "2000", "2010", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "15.0", "15.0", "", "", "80.0", "69.3", "", "50.6", "", "2", "", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.7", "80.3", "", "", "", "", "80.6"]} +{"pcdb_id": 8281, "brand_name": "Heating World Group", "model_name": "Grandee", "model_qualifier": "1.40", "winter_efficiency_pct": 85.3, "summer_efficiency_pct": 73.6, "comparative_hot_water_efficiency_pct": 53.7, "output_kw_max": 12.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008281", "000050", "0", "2012/Mar/27 10:12", "Heating World Group", "Heating World Group", "Grandee", "1.40", "", "1997", "current", "4", "2", "1", "1", "0", "", "", "1", "2", "1", "12", "12", "", "", "85.3", "73.6", "", "53.7", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "84.1", "86.4", "", "", "", "", "86.0"]} +{"pcdb_id": 8282, "brand_name": "Heating World Group", "model_name": "Grandee", "model_qualifier": "1.50", "winter_efficiency_pct": 83.6, "summer_efficiency_pct": 71.9, "comparative_hot_water_efficiency_pct": 52.5, "output_kw_max": 15.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008282", "000050", "0", "2012/Mar/27 10:12", "Heating World Group", "Heating World Group", "Grandee", "1.50", "", "1997", "current", "4", "2", "1", "1", "0", "", "", "1", "1", "1", "15", "15", "", "", "83.6", "71.9", "", "52.5", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.3", "84.9", "", "", "", "", "84.4"]} +{"pcdb_id": 8283, "brand_name": "Heating World Group", "model_name": "Grandee", "model_qualifier": "1.60", "winter_efficiency_pct": 83.6, "summer_efficiency_pct": 71.9, "comparative_hot_water_efficiency_pct": 52.5, "output_kw_max": 18.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008283", "000050", "0", "2012/Mar/27 10:12", "Heating World Group", "Heating World Group", "Grandee", "1.60", "", "1997", "current", "4", "2", "1", "1", "0", "", "", "1", "1", "1", "18", "18", "", "", "83.6", "71.9", "", "52.5", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.3", "84.9", "", "", "", "", "84.4"]} +{"pcdb_id": 8284, "brand_name": "Heating World Group", "model_name": "Grandee", "model_qualifier": "2.70", "winter_efficiency_pct": 84.4, "summer_efficiency_pct": 72.7, "comparative_hot_water_efficiency_pct": 53.1, "output_kw_max": 20.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008284", "000050", "0", "2012/Mar/27 10:12", "Heating World Group", "Heating World Group", "Grandee", "2.70", "", "1997", "current", "4", "2", "1", "1", "0", "", "", "1", "2", "1", "20", "20", "", "", "84.4", "72.7", "", "53.1", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.6", "86.1", "", "", "", "", "85.5"]} +{"pcdb_id": 8285, "brand_name": "Heating World Group", "model_name": "Grandee", "model_qualifier": "2.80", "winter_efficiency_pct": 84.4, "summer_efficiency_pct": 72.7, "comparative_hot_water_efficiency_pct": 53.1, "output_kw_max": 24.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008285", "000050", "0", "2012/Mar/27 10:12", "Heating World Group", "Heating World Group", "Grandee", "2.80", "", "1997", "current", "4", "2", "1", "1", "0", "", "", "1", "2", "1", "24", "24", "", "", "84.4", "72.7", "", "53.1", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.6", "86.1", "", "", "", "", "85.5"]} +{"pcdb_id": 8286, "brand_name": "Heating World Group", "model_name": "Grandee", "model_qualifier": "3.100", "winter_efficiency_pct": 84.4, "summer_efficiency_pct": 72.7, "comparative_hot_water_efficiency_pct": 53.1, "output_kw_max": 29.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008286", "000050", "0", "2012/Mar/27 10:12", "Heating World Group", "Heating World Group", "Grandee", "3.100", "", "1997", "current", "4", "2", "1", "1", "0", "", "", "1", "2", "1", "29", "29", "", "", "84.4", "72.7", "", "53.1", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.6", "86.1", "", "", "", "", "85.5"]} +{"pcdb_id": 8287, "brand_name": "Heating World Group", "model_name": "Grandee", "model_qualifier": "3.90", "winter_efficiency_pct": 84.4, "summer_efficiency_pct": 72.7, "comparative_hot_water_efficiency_pct": 53.1, "output_kw_max": 26.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008287", "000050", "0", "2012/Mar/27 10:12", "Heating World Group", "Heating World Group", "Grandee", "3.90", "", "1997", "current", "4", "2", "1", "1", "0", "", "", "1", "2", "1", "26", "26", "", "", "84.4", "72.7", "", "53.1", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.6", "86.1", "", "", "", "", "85.5"]} +{"pcdb_id": 8288, "brand_name": "Heating World Group", "model_name": "Grandee", "model_qualifier": "4.40", "winter_efficiency_pct": 85.3, "summer_efficiency_pct": 73.6, "comparative_hot_water_efficiency_pct": 53.7, "output_kw_max": 12.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008288", "000050", "0", "2012/Mar/27 10:12", "Heating World Group", "Heating World Group", "Grandee", "4.40", "", "1997", "current", "4", "1", "1", "1", "0", "", "", "1", "1", "1", "12", "12", "", "", "85.3", "73.6", "", "53.7", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "84.1", "86.4", "", "", "", "", "86.0"]} +{"pcdb_id": 8289, "brand_name": "Heating World Group", "model_name": "Grandee", "model_qualifier": "4.40 BF", "winter_efficiency_pct": 85.3, "summer_efficiency_pct": 73.6, "comparative_hot_water_efficiency_pct": 53.7, "output_kw_max": 12.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008289", "000050", "0", "2012/Mar/27 10:12", "Heating World Group", "Heating World Group", "Grandee", "4.40 BF", "", "1997", "current", "4", "1", "1", "1", "0", "", "", "1", "2", "1", "12", "12", "", "", "85.3", "73.6", "", "53.7", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "84.1", "86.4", "", "", "", "", "86.0"]} +{"pcdb_id": 8290, "brand_name": "Heating World Group", "model_name": "Grandee", "model_qualifier": "4.50", "winter_efficiency_pct": 83.6, "summer_efficiency_pct": 71.9, "comparative_hot_water_efficiency_pct": 52.5, "output_kw_max": 15.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008290", "000050", "0", "2012/Mar/27 10:12", "Heating World Group", "Heating World Group", "Grandee", "4.50", "", "1997", "current", "4", "1", "1", "1", "0", "", "", "1", "1", "1", "15", "15", "", "", "83.6", "71.9", "", "52.5", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.3", "84.9", "", "", "", "", "84.4"]} +{"pcdb_id": 8291, "brand_name": "Heating World Group", "model_name": "Grandee", "model_qualifier": "4.50 BF", "winter_efficiency_pct": 83.6, "summer_efficiency_pct": 71.9, "comparative_hot_water_efficiency_pct": 52.5, "output_kw_max": 15.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008291", "000050", "0", "2012/Mar/27 10:12", "Heating World Group", "Heating World Group", "Grandee", "4.50 BF", "", "1997", "current", "4", "1", "1", "1", "0", "", "", "1", "2", "1", "15", "15", "", "", "83.6", "71.9", "", "52.5", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.3", "84.9", "", "", "", "", "84.4"]} +{"pcdb_id": 8292, "brand_name": "Heating World Group", "model_name": "Grandee", "model_qualifier": "4.60", "winter_efficiency_pct": 83.6, "summer_efficiency_pct": 71.9, "comparative_hot_water_efficiency_pct": 52.5, "output_kw_max": 18.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008292", "000050", "0", "2012/Mar/27 10:12", "Heating World Group", "Heating World Group", "Grandee", "4.60", "", "1997", "current", "4", "1", "1", "1", "0", "", "", "1", "1", "1", "18", "18", "", "", "83.6", "71.9", "", "52.5", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.3", "84.9", "", "", "", "", "84.4"]} +{"pcdb_id": 8293, "brand_name": "Heating World Group", "model_name": "Grandee", "model_qualifier": "4.60 BF", "winter_efficiency_pct": 83.6, "summer_efficiency_pct": 71.9, "comparative_hot_water_efficiency_pct": 52.5, "output_kw_max": 18.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008293", "000050", "0", "2012/Mar/27 10:12", "Heating World Group", "Heating World Group", "Grandee", "4.60 BF", "", "1997", "current", "4", "1", "1", "1", "0", "", "", "1", "2", "1", "18", "18", "", "", "83.6", "71.9", "", "52.5", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.3", "84.9", "", "", "", "", "84.4"]} +{"pcdb_id": 8294, "brand_name": "Heating World Group", "model_name": "Grandee", "model_qualifier": "5.40", "winter_efficiency_pct": 85.3, "summer_efficiency_pct": 73.6, "comparative_hot_water_efficiency_pct": 53.7, "output_kw_max": 12.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008294", "000050", "0", "2012/Mar/27 10:12", "Heating World Group", "Heating World Group", "Grandee", "5.40", "", "1997", "current", "4", "1", "1", "1", "0", "", "", "1", "1", "1", "12", "12", "", "", "85.3", "73.6", "", "53.7", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "84.1", "86.4", "", "", "", "", "86.0"]} +{"pcdb_id": 8295, "brand_name": "Heating World Group", "model_name": "Grandee", "model_qualifier": "5.40 BF", "winter_efficiency_pct": 85.3, "summer_efficiency_pct": 73.6, "comparative_hot_water_efficiency_pct": 53.7, "output_kw_max": 12.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008295", "000050", "0", "2012/Mar/27 10:12", "Heating World Group", "Heating World Group", "Grandee", "5.40 BF", "", "1997", "current", "4", "1", "1", "1", "0", "", "", "1", "2", "1", "12", "12", "", "", "85.3", "73.6", "", "53.7", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "84.1", "86.4", "", "", "", "", "86.0"]} +{"pcdb_id": 8296, "brand_name": "Heating World Group", "model_name": "Grandee", "model_qualifier": "5.50", "winter_efficiency_pct": 83.6, "summer_efficiency_pct": 71.9, "comparative_hot_water_efficiency_pct": 52.5, "output_kw_max": 15.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008296", "000050", "0", "2012/Mar/27 10:12", "Heating World Group", "Heating World Group", "Grandee", "5.50", "", "1997", "current", "4", "1", "1", "1", "0", "", "", "1", "1", "1", "15", "15", "", "", "83.6", "71.9", "", "52.5", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.3", "84.9", "", "", "", "", "84.4"]} +{"pcdb_id": 8297, "brand_name": "Heating World Group", "model_name": "Grandee", "model_qualifier": "5.50 BF", "winter_efficiency_pct": 83.6, "summer_efficiency_pct": 71.9, "comparative_hot_water_efficiency_pct": 52.5, "output_kw_max": 15.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008297", "000050", "0", "2012/Mar/27 10:12", "Heating World Group", "Heating World Group", "Grandee", "5.50 BF", "", "1997", "current", "4", "1", "1", "1", "0", "", "", "1", "2", "1", "15", "15", "", "", "83.6", "71.9", "", "52.5", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.3", "84.9", "", "", "", "", "84.4"]} +{"pcdb_id": 8298, "brand_name": "Heating World Group", "model_name": "Grandee", "model_qualifier": "5.60", "winter_efficiency_pct": 83.6, "summer_efficiency_pct": 71.9, "comparative_hot_water_efficiency_pct": 52.5, "output_kw_max": 18.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008298", "000050", "0", "2012/Mar/27 10:12", "Heating World Group", "Heating World Group", "Grandee", "5.60", "", "1997", "current", "4", "1", "1", "1", "0", "", "", "1", "1", "1", "18", "18", "", "", "83.6", "71.9", "", "52.5", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.3", "84.9", "", "", "", "", "84.4"]} +{"pcdb_id": 8299, "brand_name": "Heating World Group", "model_name": "Grandee", "model_qualifier": "5.60 BF", "winter_efficiency_pct": 83.6, "summer_efficiency_pct": 71.9, "comparative_hot_water_efficiency_pct": 52.5, "output_kw_max": 18.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008299", "000050", "0", "2012/Mar/27 10:12", "Heating World Group", "Heating World Group", "Grandee", "5.60 BF", "", "1997", "current", "4", "1", "1", "1", "0", "", "", "1", "2", "1", "18", "18", "", "", "83.6", "71.9", "", "52.5", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.3", "84.9", "", "", "", "", "84.4"]} +{"pcdb_id": 8300, "brand_name": "Heating World Group", "model_name": "Grandee", "model_qualifier": "6.60", "winter_efficiency_pct": 85.6, "summer_efficiency_pct": 73.9, "comparative_hot_water_efficiency_pct": 54.0, "output_kw_max": 18.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008300", "000050", "0", "2012/Mar/27 10:12", "Heating World Group", "Heating World Group", "Grandee", "6.60", "", "1997", "current", "4", "1", "1", "1", "0", "", "", "1", "1", "1", "18", "18", "", "", "85.6", "73.9", "", "54.0", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.7", "85.0", "", "", "", "", "85.3"]} +{"pcdb_id": 8301, "brand_name": "Heating World Group", "model_name": "Grandee", "model_qualifier": "6.60 BF", "winter_efficiency_pct": 85.6, "summer_efficiency_pct": 73.9, "comparative_hot_water_efficiency_pct": 54.0, "output_kw_max": 18.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008301", "000050", "0", "2012/Mar/27 10:12", "Heating World Group", "Heating World Group", "Grandee", "6.60 BF", "", "1997", "current", "4", "1", "1", "1", "0", "", "", "1", "2", "1", "18", "18", "", "", "85.6", "73.9", "", "54.0", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.7", "85.0", "", "", "", "", "85.3"]} +{"pcdb_id": 8302, "brand_name": "Heating World Group", "model_name": "Grandee", "model_qualifier": "6.70", "winter_efficiency_pct": 85.6, "summer_efficiency_pct": 73.9, "comparative_hot_water_efficiency_pct": 54.0, "output_kw_max": 20.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008302", "000050", "0", "2012/Mar/27 10:12", "Heating World Group", "Heating World Group", "Grandee", "6.70", "", "1997", "current", "4", "1", "1", "1", "0", "", "", "1", "1", "1", "20", "20", "", "", "85.6", "73.9", "", "54.0", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.7", "85.0", "", "", "", "", "85.3"]} +{"pcdb_id": 8303, "brand_name": "Heating World Group", "model_name": "Grandee", "model_qualifier": "6.70 BF", "winter_efficiency_pct": 85.6, "summer_efficiency_pct": 73.9, "comparative_hot_water_efficiency_pct": 54.0, "output_kw_max": 20.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008303", "000050", "0", "2012/Mar/27 10:12", "Heating World Group", "Heating World Group", "Grandee", "6.70 BF", "", "1997", "current", "4", "1", "1", "1", "0", "", "", "1", "2", "1", "20", "20", "", "", "85.6", "73.9", "", "54.0", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.7", "85.0", "", "", "", "", "85.3"]} +{"pcdb_id": 8304, "brand_name": "Heating World Group", "model_name": "Grandee", "model_qualifier": "6.80", "winter_efficiency_pct": 85.6, "summer_efficiency_pct": 73.9, "comparative_hot_water_efficiency_pct": 54.0, "output_kw_max": 23.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008304", "000050", "0", "2012/Mar/27 10:12", "Heating World Group", "Heating World Group", "Grandee", "6.80", "", "1997", "current", "4", "1", "1", "1", "0", "", "", "1", "1", "1", "23", "23", "", "", "85.6", "73.9", "", "54.0", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.7", "85.0", "", "", "", "", "85.3"]} +{"pcdb_id": 8305, "brand_name": "Heating World Group", "model_name": "Grandee", "model_qualifier": "6.80 BF", "winter_efficiency_pct": 85.6, "summer_efficiency_pct": 73.9, "comparative_hot_water_efficiency_pct": 54.0, "output_kw_max": 23.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008305", "000050", "0", "2012/Mar/27 10:12", "Heating World Group", "Heating World Group", "Grandee", "6.80 BF", "", "1997", "current", "4", "1", "1", "1", "0", "", "", "1", "2", "1", "23", "23", "", "", "85.6", "73.9", "", "54.0", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.7", "85.0", "", "", "", "", "85.3"]} +{"pcdb_id": 8306, "brand_name": "Heating World Group", "model_name": "Grandee", "model_qualifier": "7.90", "winter_efficiency_pct": 85.6, "summer_efficiency_pct": 73.9, "comparative_hot_water_efficiency_pct": 54.0, "output_kw_max": 26.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008306", "000050", "0", "2012/Mar/27 10:12", "Heating World Group", "Heating World Group", "Grandee", "7.90", "", "1997", "current", "4", "1", "1", "1", "0", "", "", "1", "1", "1", "26", "26", "", "", "85.6", "73.9", "", "54.0", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.7", "85.0", "", "", "", "", "85.3"]} +{"pcdb_id": 8307, "brand_name": "Heating World Group", "model_name": "Grandee", "model_qualifier": "7.90 BF", "winter_efficiency_pct": 85.6, "summer_efficiency_pct": 73.9, "comparative_hot_water_efficiency_pct": 54.0, "output_kw_max": 26.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008307", "000050", "0", "2012/Mar/27 10:12", "Heating World Group", "Heating World Group", "Grandee", "7.90 BF", "", "1997", "current", "4", "1", "1", "1", "0", "", "", "1", "2", "1", "26", "26", "", "", "85.6", "73.9", "", "54.0", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.7", "85.0", "", "", "", "", "85.3"]} +{"pcdb_id": 8308, "brand_name": "Heating World Group", "model_name": "Grandee", "model_qualifier": "7.100", "winter_efficiency_pct": 85.6, "summer_efficiency_pct": 73.9, "comparative_hot_water_efficiency_pct": 54.0, "output_kw_max": 29.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008308", "000050", "0", "2012/Mar/27 10:12", "Heating World Group", "Heating World Group", "Grandee", "7.100", "", "1997", "current", "4", "1", "1", "1", "0", "", "", "1", "1", "1", "29", "29", "", "", "85.6", "73.9", "", "54.0", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.7", "85.0", "", "", "", "", "85.3"]} +{"pcdb_id": 8309, "brand_name": "Heating World Group", "model_name": "Grandee", "model_qualifier": "7.100 BF", "winter_efficiency_pct": 85.6, "summer_efficiency_pct": 73.9, "comparative_hot_water_efficiency_pct": 54.0, "output_kw_max": 29.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008309", "000050", "0", "2012/Mar/27 10:12", "Heating World Group", "Heating World Group", "Grandee", "7.100 BF", "", "1997", "current", "4", "1", "1", "1", "0", "", "", "1", "2", "1", "29", "29", "", "", "85.6", "73.9", "", "54.0", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.7", "85.0", "", "", "", "", "85.3"]} +{"pcdb_id": 8310, "brand_name": "Heating World Group", "model_name": "Grandee", "model_qualifier": "7.110", "winter_efficiency_pct": 85.6, "summer_efficiency_pct": 73.9, "comparative_hot_water_efficiency_pct": 54.0, "output_kw_max": 32.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008310", "000050", "0", "2012/Mar/27 10:12", "Heating World Group", "Heating World Group", "Grandee", "7.110", "", "1997", "current", "4", "1", "1", "1", "0", "", "", "1", "1", "1", "32", "32", "", "", "85.6", "73.9", "", "54.0", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.7", "85.0", "", "", "", "", "85.3"]} +{"pcdb_id": 8312, "brand_name": "Heating World Group", "model_name": "Grandee", "model_qualifier": "7.110 BF", "winter_efficiency_pct": 85.6, "summer_efficiency_pct": 73.9, "comparative_hot_water_efficiency_pct": 54.0, "output_kw_max": 32.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008312", "000050", "0", "2012/Mar/27 10:12", "Heating World Group", "Heating World Group", "Grandee", "7.110 BF", "", "1997", "current", "4", "1", "1", "1", "0", "", "", "1", "2", "1", "32", "32", "", "", "85.6", "73.9", "", "54.0", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.7", "85.0", "", "", "", "", "85.3"]} +{"pcdb_id": 8313, "brand_name": "Heating World Group", "model_name": "Grandee", "model_qualifier": "8.120", "winter_efficiency_pct": 85.6, "summer_efficiency_pct": 73.9, "comparative_hot_water_efficiency_pct": 54.0, "output_kw_max": 35.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008313", "000050", "0", "2012/Mar/27 10:12", "Heating World Group", "Heating World Group", "Grandee", "8.120", "", "1997", "current", "4", "1", "1", "1", "0", "", "", "1", "1", "1", "35", "35", "", "", "85.6", "73.9", "", "54.0", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.7", "85.0", "", "", "", "", "85.3"]} +{"pcdb_id": 8314, "brand_name": "Heating World Group", "model_name": "Grandee", "model_qualifier": "8.120 BF", "winter_efficiency_pct": 85.6, "summer_efficiency_pct": 73.9, "comparative_hot_water_efficiency_pct": 54.0, "output_kw_max": 35.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008314", "000050", "0", "2012/Mar/27 10:12", "Heating World Group", "Heating World Group", "Grandee", "8.120 BF", "", "1997", "current", "4", "1", "1", "1", "0", "", "", "1", "2", "1", "35", "35", "", "", "85.6", "73.9", "", "54.0", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.7", "85.0", "", "", "", "", "85.3"]} +{"pcdb_id": 8315, "brand_name": "Heating World Group", "model_name": "Grandee", "model_qualifier": "8.135", "winter_efficiency_pct": 85.6, "summer_efficiency_pct": 73.9, "comparative_hot_water_efficiency_pct": 54.0, "output_kw_max": 40.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008315", "000050", "0", "2012/Mar/27 10:12", "Heating World Group", "Heating World Group", "Grandee", "8.135", "", "1997", "current", "4", "1", "1", "1", "0", "", "", "1", "1", "1", "40", "40", "", "", "85.6", "73.9", "", "54.0", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.7", "85.0", "", "", "", "", "85.3"]} +{"pcdb_id": 8316, "brand_name": "Heating World Group", "model_name": "Grandee", "model_qualifier": "8.135 BF", "winter_efficiency_pct": 85.6, "summer_efficiency_pct": 73.9, "comparative_hot_water_efficiency_pct": 54.0, "output_kw_max": 40.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008316", "000050", "0", "2012/Mar/27 10:12", "Heating World Group", "Heating World Group", "Grandee", "8.135 BF", "", "1997", "current", "4", "1", "1", "1", "0", "", "", "1", "2", "1", "40", "40", "", "", "85.6", "73.9", "", "54.0", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.7", "85.0", "", "", "", "", "85.3"]} +{"pcdb_id": 8317, "brand_name": "Heating World Group", "model_name": "Grandee", "model_qualifier": "8.150", "winter_efficiency_pct": 85.6, "summer_efficiency_pct": 73.9, "comparative_hot_water_efficiency_pct": 54.0, "output_kw_max": 44.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008317", "000050", "0", "2012/Mar/27 10:12", "Heating World Group", "Heating World Group", "Grandee", "8.150", "", "1997", "current", "4", "1", "1", "1", "0", "", "", "1", "1", "1", "44", "44", "", "", "85.6", "73.9", "", "54.0", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.7", "85.0", "", "", "", "", "85.3"]} +{"pcdb_id": 8318, "brand_name": "Heating World Group", "model_name": "Grandee", "model_qualifier": "8.150 BF", "winter_efficiency_pct": 85.6, "summer_efficiency_pct": 73.9, "comparative_hot_water_efficiency_pct": 54.0, "output_kw_max": 44.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008318", "000050", "0", "2012/Mar/27 10:12", "Heating World Group", "Heating World Group", "Grandee", "8.150 BF", "", "1997", "current", "4", "1", "1", "1", "0", "", "", "1", "2", "1", "44", "44", "", "", "85.6", "73.9", "", "54.0", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.7", "85.0", "", "", "", "", "85.3"]} +{"pcdb_id": 8319, "brand_name": "Heating World Group", "model_name": "Sorrento", "model_qualifier": "12/15", "winter_efficiency_pct": 85.3, "summer_efficiency_pct": 73.6, "comparative_hot_water_efficiency_pct": 53.7, "output_kw_max": 12.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008319", "000050", "0", "2012/Mar/27 10:12", "Heating World Group", "Heating World Group", "Sorrento", "12/15", "", "1997", "current", "4", "1", "1", "1", "0", "", "", "1", "1", "1", "12", "12", "", "", "85.3", "73.6", "", "53.7", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "84.1", "86.4", "", "", "", "", "86.0"]} +{"pcdb_id": 8320, "brand_name": "Heating World Group", "model_name": "Sorrento", "model_qualifier": "15/18", "winter_efficiency_pct": 83.6, "summer_efficiency_pct": 71.9, "comparative_hot_water_efficiency_pct": 52.5, "output_kw_max": 15.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008320", "000050", "0", "2012/Mar/27 10:12", "Heating World Group", "Heating World Group", "Sorrento", "15/18", "", "1997", "current", "4", "1", "1", "1", "0", "", "", "1", "1", "1", "15", "15", "", "", "83.6", "71.9", "", "52.5", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.3", "84.9", "", "", "", "", "84.4"]} +{"pcdb_id": 8321, "brand_name": "Heating World Group", "model_name": "Sorrento", "model_qualifier": "18/21", "winter_efficiency_pct": 83.6, "summer_efficiency_pct": 71.9, "comparative_hot_water_efficiency_pct": 52.5, "output_kw_max": 18.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008321", "000050", "0", "2012/Mar/27 10:12", "Heating World Group", "Heating World Group", "Sorrento", "18/21", "", "1997", "current", "4", "1", "1", "1", "0", "", "", "1", "1", "1", "18", "18", "", "", "83.6", "71.9", "", "52.5", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.3", "84.9", "", "", "", "", "84.4"]} +{"pcdb_id": 8322, "brand_name": "Heating World Group", "model_name": "Grandee Combi Floor", "model_qualifier": "15-20", "winter_efficiency_pct": 83.6, "summer_efficiency_pct": 74.1, "comparative_hot_water_efficiency_pct": 52.1, "output_kw_max": 20.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008322", "000050", "0", "2000/Dec/18 13:33", "Heating World Group", "Heating World Group", "Grandee Combi Floor", "15-20", "", "1997", "current", "4", "1", "1", "2", "0", "", "", "1", "1", "1", "15", "20", "", "", "83.6", "74.1", "", "52.1", "", "2", "", "", "202", "1", "1", "", "", "0", "1", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.2", "84.5", "", "", "", "", "85.0"]} +{"pcdb_id": 8323, "brand_name": "Heating World Group", "model_name": "Grandee Combi Floor", "model_qualifier": "15-20 BF", "winter_efficiency_pct": 83.6, "summer_efficiency_pct": 74.1, "comparative_hot_water_efficiency_pct": 52.1, "output_kw_max": 20.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008323", "000050", "0", "2001/Jan/12 10:52", "Heating World Group", "Heating World Group", "Grandee Combi Floor", "15-20 BF", "", "1997", "current", "4", "1", "1", "2", "0", "", "", "1", "2", "1", "15", "20", "", "", "83.6", "74.1", "", "52.1", "", "2", "", "", "202", "1", "1", "", "", "0", "1", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.2", "84.5", "", "", "", "", "85.0"]} +{"pcdb_id": 8324, "brand_name": "Solarcombi", "model_name": "EC-Compact", "model_qualifier": "EC25 H", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 25.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008324", "000209", "0", "2012/Mar/27 10:12", "Coopra BV", "Solarcombi", "EC-Compact", "EC25 H", "", "1998", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "25", "25", "", "", "88.8", "79.8", "", "58.3", "", "2", "", "", "102", "1", "2", "85", "20", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.0", "98.5", "", "", "", "", "96.7"]} +{"pcdb_id": 8326, "brand_name": "Solarcombi", "model_name": "EC-Compact", "model_qualifier": "EC25 HS", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 25.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008326", "000209", "0", "2012/Mar/27 10:12", "Coopra BV", "Solarcombi", "EC-Compact", "EC25 HS", "", "1998", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "25", "25", "", "", "88.8", "79.8", "", "58.3", "", "2", "", "", "102", "1", "2", "85", "20", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.0", "98.5", "", "", "", "", "96.7"]} +{"pcdb_id": 8328, "brand_name": "Solarcombi", "model_name": "EC-Compact", "model_qualifier": "EC25 S", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 56.4, "output_kw_max": 25.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008328", "000209", "0", "2006/Jan/17 12:31", "Coopra BV", "Solarcombi", "EC-Compact", "EC25 S", "", "1998", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "25", "25", "", "", "88.8", "80.2", "", "56.4", "", "2", "", "", "104", "1", "2", "85", "20", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.0", "98.5", "", "", "", "", "96.7"]} +{"pcdb_id": 8331, "brand_name": "Keston", "model_name": "Celsius", "model_qualifier": "25P", "winter_efficiency_pct": 90.0, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 59.2, "output_kw_max": 25.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008331", "000022", "0", "2012/Mar/27 10:12", "Keston Boilers", "Keston", "Celsius", "25P", "Celsius 25P", "2001", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "25", "25", "", "", "90.0", "81.0", "", "59.2", "", "2", "0", "", "102", "1", "2", "160", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "91.0", "98.5", "", "", "", "", "97.1"]} +{"pcdb_id": 8332, "brand_name": "Potterton International Heating", "model_name": "FRS 52", "model_qualifier": "", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": null, "final_year_of_manufacture": 1972, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008332", "000005", "0", "2010/Sep/13 17:03", "Potterton International Heating", "Potterton International Heating", "FRS 52", "", "41 595 60", "", "1972", "1", "0", "0", "1", "0", "", "", "1", "2", "1", "", "", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "0", "0", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 8336, "brand_name": "MHS Boilers", "model_name": "Strata 1", "model_qualifier": "HE 60", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 60.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008336", "000024", "0", "2012/Mar/27 10:12", "MHS Boilers", "MHS Boilers", "Strata 1", "HE 60", "0063 AT 3341", "1998", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "60.4", "60.4", "", "", "88.8", "79.8", "", "58.3", "", "2", "", "", "102", "1", "2", "115", "20", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "98.7", "", "", "", "", "96.8"]} +{"pcdb_id": 8338, "brand_name": "MHS Boilers", "model_name": "Strata 1", "model_qualifier": "HE-45", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 45.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008338", "000024", "0", "2012/Mar/27 10:12", "MHS Boilers", "MHS Boilers", "Strata 1", "HE-45", "0063 AT 3341", "1998", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "45.6", "45.6", "", "", "88.7", "79.7", "", "58.3", "", "2", "", "", "102", "1", "2", "115", "20", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "98.6", "", "", "", "", "96.6"]} +{"pcdb_id": 8340, "brand_name": "MHS Boilers", "model_name": "Strata 1", "model_qualifier": "HEI-38/45 Combi", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 46.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008340", "000024", "0", "2012/Mar/27 10:12", "MHS Boilers", "MHS Boilers", "Strata 1", "HEI-38/45 Combi", "0063AT3340", "1998", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "46.0", "46.0", "", "", "88.3", "79.3", "", "57.9", "", "2", "", "", "102", "1", "2", "70", "10", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "97.5", "", "", "", "", "95.7"]} +{"pcdb_id": 8342, "brand_name": "MHS Boilers", "model_name": "Strata 1", "model_qualifier": "HE-38", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 38.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008342", "000024", "0", "2012/Mar/27 10:12", "MHS Boilers", "MHS Boilers", "Strata 1", "HE-38", "0063AT3340", "1998", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "38", "38.0", "", "", "88.3", "79.3", "", "57.9", "", "2", "", "", "102", "1", "2", "70", "10", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "97.5", "", "", "", "", "95.7"]} +{"pcdb_id": 8344, "brand_name": "Ariston", "model_name": "Microsystem 28 RFFI", "model_qualifier": "", "winter_efficiency_pct": 81.3, "summer_efficiency_pct": 70.6, "comparative_hot_water_efficiency_pct": 51.6, "output_kw_max": 27.8, "final_year_of_manufacture": 2007, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008344", "000080", "0", "2012/Mar/27 10:12", "Merloni TermoSanitari SpA", "Ariston", "Microsystem 28 RFFI", "", "GC No. 41-116-07", "2000", "2007", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "27.8", "27.8", "", "", "81.3", "70.6", "", "51.6", "", "2", "", "", "102", "1", "2", "155", "7", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "84.2", "81.7", "", "", "", "", "82.2"]} +{"pcdb_id": 8346, "brand_name": "Vokera", "model_name": "Linea 24", "model_qualifier": "e", "winter_efficiency_pct": 79.1, "summer_efficiency_pct": 69.0, "comparative_hot_water_efficiency_pct": 48.5, "output_kw_max": 23.7, "final_year_of_manufacture": 2010, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008346", "000011", "0", "2010/Oct/21 11:22", "Vokera", "Vokera", "Linea 24", "e", "47-094-27", "2001", "2010", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "23.7", "23.7", "", "", "79.1", "69.0", "", "48.5", "", "2", "", "", "104", "1", "2", "125", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "83.0", "77.7", "", "", "", "", "78.7"]} +{"pcdb_id": 8348, "brand_name": "Vokera", "model_name": "Linea 28", "model_qualifier": "e", "winter_efficiency_pct": 78.9, "summer_efficiency_pct": 68.8, "comparative_hot_water_efficiency_pct": 48.4, "output_kw_max": 28.0, "final_year_of_manufacture": 2010, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008348", "000011", "0", "2010/Oct/21 11:22", "Vokera", "Vokera", "Linea 28", "e", "47-094-28", "2001", "2010", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "28", "28", "", "", "78.9", "68.8", "", "48.4", "", "2", "", "", "104", "1", "2", "125", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "83.0", "77.3", "", "", "", "", "78.4"]} +{"pcdb_id": 8349, "brand_name": "Baxi Heating", "model_name": "FF40 from Potterton", "model_qualifier": "", "winter_efficiency_pct": 72.7, "summer_efficiency_pct": 62.6, "comparative_hot_water_efficiency_pct": 45.7, "output_kw_max": 11.72, "final_year_of_manufacture": 2002, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008349", "000005", "0", "2012/Mar/27 10:12", "Baxi Heating", "Baxi Heating", "FF40 from Potterton", "", "LTE", "2001", "2002", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "8.79", "11.72", "", "", "72.7", "62.6", "", "45.7", "", "2", "", "", "101", "1", "1", "80", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "74.9", "73.7", "", "", "", "", "73.9"]} +{"pcdb_id": 8350, "brand_name": "Baxi Heating", "model_name": "FF50 from Potterton", "model_qualifier": "", "winter_efficiency_pct": 76.3, "summer_efficiency_pct": 66.2, "comparative_hot_water_efficiency_pct": 48.4, "output_kw_max": 14.65, "final_year_of_manufacture": 2002, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008350", "000005", "0", "2012/Mar/27 10:12", "Baxi Heating", "Baxi Heating", "FF50 from Potterton", "", "LTF", "2001", "2002", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "11.72", "14.65", "", "", "76.3", "66.2", "", "48.4", "", "2", "", "", "101", "1", "1", "80", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "78.6", "77.2", "", "", "", "", "77.5"]} +{"pcdb_id": 8351, "brand_name": "Baxi Heating", "model_name": "FF60 from Potterton", "model_qualifier": "", "winter_efficiency_pct": 76.0, "summer_efficiency_pct": 65.9, "comparative_hot_water_efficiency_pct": 48.2, "output_kw_max": 17.58, "final_year_of_manufacture": 2002, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008351", "000005", "0", "2012/Mar/27 10:12", "Baxi Heating", "Baxi Heating", "FF60 from Potterton", "", "LTG", "2001", "2002", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "14.65", "17.58", "", "", "76.0", "65.9", "", "48.2", "", "2", "", "", "101", "1", "1", "80", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "78.3", "76.9", "", "", "", "", "77.2"]} +{"pcdb_id": 8352, "brand_name": "Baxi Heating", "model_name": "FF80 from Potterton", "model_qualifier": "", "winter_efficiency_pct": 75.3, "summer_efficiency_pct": 65.2, "comparative_hot_water_efficiency_pct": 47.6, "output_kw_max": 23.45, "final_year_of_manufacture": 2002, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008352", "000005", "0", "2012/Mar/27 10:12", "Baxi Heating", "Baxi Heating", "FF80 from Potterton", "", "LTH", "2001", "2002", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "17.58", "23.45", "", "", "75.3", "65.2", "", "47.6", "", "2", "", "", "101", "1", "1", "80", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "77.4", "76.4", "", "", "", "", "76.6"]} +{"pcdb_id": 8353, "brand_name": "Baxi", "model_name": "System", "model_qualifier": "60/100", "winter_efficiency_pct": 79.2, "summer_efficiency_pct": 68.5, "comparative_hot_water_efficiency_pct": 50.1, "output_kw_max": 32.6, "final_year_of_manufacture": 2005, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008353", "000005", "0", "2012/Mar/27 10:12", "Baxi SpA", "Baxi", "System", "60/100", "GC no. 47-075-19", "2001", "2005", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "32.6", "32.6", "", "", "79.2", "68.5", "", "50.1", "", "2", "", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.2", "79.3", "", "", "", "", "79.6"]} +{"pcdb_id": 8354, "brand_name": "Baxi", "model_name": "System", "model_qualifier": "35/60", "winter_efficiency_pct": 79.8, "summer_efficiency_pct": 69.1, "comparative_hot_water_efficiency_pct": 50.5, "output_kw_max": 19.4, "final_year_of_manufacture": 2006, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008354", "000005", "0", "2012/Mar/27 10:12", "Baxi SpA", "Baxi", "System", "35/60", "GC no. 47-075-18", "2001", "2006", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "19.4", "19.4", "", "", "79.8", "69.1", "", "50.5", "", "2", "", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.1", "79.6", "", "", "", "", "80.0"]} +{"pcdb_id": 8355, "brand_name": "Baxi", "model_name": "Maxflow Combi", "model_qualifier": "FS", "winter_efficiency_pct": 79.7, "summer_efficiency_pct": 70.6, "comparative_hot_water_efficiency_pct": 31.0, "output_kw_max": 31.1, "final_year_of_manufacture": 2003, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008355", "000005", "0", "2024/Jan/31 10:17", "Baxi SpA", "Baxi", "Maxflow Combi", "FS", "GC no. 47-075-10", "2001", "2003", "1", "1", "1", "2", "0", "", "", "1", "2", "2", "31.1", "31.1", "", "", "79.7", "70.6", "", "31.0", "", "2", "", "", "106", "1", "2", "", "", "2", "2", "0", "54", "0", "14", "2", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.5", "79.0", "", "", "", "", "79.5"]} +{"pcdb_id": 8356, "brand_name": "Baxi", "model_name": "Maxflow Combi", "model_qualifier": "WM", "winter_efficiency_pct": 79.8, "summer_efficiency_pct": 70.7, "comparative_hot_water_efficiency_pct": 31.1, "output_kw_max": 31.1, "final_year_of_manufacture": 2006, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008356", "000005", "0", "2024/Jan/31 10:17", "Baxi SpA", "Baxi", "Maxflow Combi", "WM", "GC no. 47-075-03", "2001", "2006", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "31.1", "31.1", "", "", "79.8", "70.7", "", "31.1", "", "2", "", "", "106", "1", "2", "", "", "2", "2", "0", "54", "0", "14", "2", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.6", "79.2", "", "", "", "", "79.7"]} +{"pcdb_id": 8357, "brand_name": "Baxi", "model_name": "Combi", "model_qualifier": "Instant 105 e", "winter_efficiency_pct": 79.4, "summer_efficiency_pct": 69.3, "comparative_hot_water_efficiency_pct": 48.7, "output_kw_max": 34.3, "final_year_of_manufacture": 2011, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008357", "000005", "0", "2013/May/07 10:02", "Baxi SpA", "Baxi", "Combi", "Instant 105 e", "GC no. 47-075-09", "2001", "2011", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "34.3", "34.3", "", "", "79.4", "69.3", "", "48.7", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.6", "79.6", "", "", "", "", "80.0"]} +{"pcdb_id": 8358, "brand_name": "Baxi", "model_name": "Combi", "model_qualifier": "105 e", "winter_efficiency_pct": 79.4, "summer_efficiency_pct": 69.3, "comparative_hot_water_efficiency_pct": 48.7, "output_kw_max": 34.3, "final_year_of_manufacture": 2011, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008358", "000005", "0", "2013/May/07 10:03", "Baxi SpA", "Baxi", "Combi", "105 e", "GC no. 47-075-08", "2001", "2011", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "34.3", "34.3", "", "", "79.4", "69.3", "", "48.7", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.6", "79.6", "", "", "", "", "80.0"]} +{"pcdb_id": 8359, "brand_name": "Baxi", "model_name": "Combi", "model_qualifier": "80 Maxflue", "winter_efficiency_pct": 79.4, "summer_efficiency_pct": 69.3, "comparative_hot_water_efficiency_pct": 48.8, "output_kw_max": 26.3, "final_year_of_manufacture": 2003, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008359", "000005", "0", "2006/Jan/17 12:55", "Baxi SpA", "Baxi", "Combi", "80 Maxflue", "GC no. 47-075-07", "2001", "2003", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "26.3", "26.3", "", "", "79.4", "69.3", "", "48.8", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.2", "79.1", "", "", "", "", "79.7"]} +{"pcdb_id": 8360, "brand_name": "Baxi", "model_name": "Combi", "model_qualifier": "80 Eco", "winter_efficiency_pct": 79.5, "summer_efficiency_pct": 69.4, "comparative_hot_water_efficiency_pct": 48.8, "output_kw_max": 26.3, "final_year_of_manufacture": 2006, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008360", "000005", "0", "2006/Nov/21 10:07", "Baxi SpA", "Baxi", "Combi", "80 Eco", "GC no. 47-075-05", "2001", "2006", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "26.3", "26.3", "", "", "79.5", "69.4", "", "48.8", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.2", "79.2", "", "", "", "", "79.8"]} +{"pcdb_id": 8361, "brand_name": "Baxi", "model_name": "Combi", "model_qualifier": "80 e", "winter_efficiency_pct": 79.5, "summer_efficiency_pct": 69.4, "comparative_hot_water_efficiency_pct": 48.8, "output_kw_max": 26.3, "final_year_of_manufacture": 2011, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008361", "000005", "0", "2013/May/07 10:03", "Baxi SpA", "Baxi", "Combi", "80 e", "GC no. 47-075-06", "2001", "2011", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "26.3", "26.3", "", "", "79.5", "69.4", "", "48.8", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.2", "79.2", "", "", "", "", "79.8"]} +{"pcdb_id": 8362, "brand_name": "Worcester", "model_name": "Bosch/British Gas CC1", "model_qualifier": "ZWB 7-29A", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 55.9, "output_kw_max": 29.2, "final_year_of_manufacture": 2002, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008362", "000035", "0", "2006/Jan/17 12:55", "Worcester Heat Systems", "Worcester", "Bosch/British Gas CC1", "ZWB 7-29A", "", "2001", "2002", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "29.2", "29.2", "", "", "88.1", "79.5", "", "55.9", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.9", "96.8", "", "", "", "", "95.3"]} +{"pcdb_id": 8363, "brand_name": "Worcester", "model_name": "Bosch/British Gas CS1", "model_qualifier": "ZB 7-28A", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 27.4, "final_year_of_manufacture": 2003, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008363", "000035", "0", "2012/Mar/27 10:12", "Worcester Heat Systems", "Worcester", "Bosch/British Gas CS1", "ZB 7-28A", "", "2001", "2003", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "27.4", "27.4", "", "", "88.1", "79.1", "", "57.8", "", "2", "", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.9", "96.8", "", "", "", "", "95.3"]} +{"pcdb_id": 8364, "brand_name": "Worcester", "model_name": "Bosch/British Gas ICC2", "model_qualifier": "ZWBR 8-30A", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 56.5, "output_kw_max": 30.2, "final_year_of_manufacture": 2003, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008364", "000035", "0", "2006/Jan/17 12:55", "Worcester Heat Systems", "Worcester", "Bosch/British Gas ICC2", "ZWBR 8-30A", "", "2001", "2003", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "30.2", "30.2", "", "", "88.9", "80.3", "", "56.5", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.5", "98.9", "", "", "", "", "96.9"]} +{"pcdb_id": 8365, "brand_name": "Worcester", "model_name": "Bosch/British Gas ICC2", "model_qualifier": "ZWBR 11-37A", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 56.5, "output_kw_max": 37.1, "final_year_of_manufacture": 2003, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008365", "000035", "0", "2006/Jan/17 12:55", "Worcester Heat Systems", "Worcester", "Bosch/British Gas ICC2", "ZWBR 11-37A", "", "2001", "2003", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "37.1", "37.1", "", "", "88.9", "80.3", "", "56.5", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.5", "98.9", "", "", "", "", "96.9"]} +{"pcdb_id": 8366, "brand_name": "Worcester", "model_name": "Bosch/British Gas ICS1", "model_qualifier": "ZSBR 7-28A", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 27.4, "final_year_of_manufacture": 2003, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008366", "000035", "0", "2012/Mar/27 10:12", "Worcester Heat Systems", "Worcester", "Bosch/British Gas ICS1", "ZSBR 7-28A", "", "2001", "2003", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "27.4", "27.4", "", "", "88.1", "79.1", "", "57.8", "", "2", "", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.9", "96.8", "", "", "", "", "95.3"]} +{"pcdb_id": 8367, "brand_name": "Worcester", "model_name": "Bosch/British Gas ICS1", "model_qualifier": "ZBR 8-35A", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 34.7, "final_year_of_manufacture": 2003, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008367", "000035", "0", "2012/Mar/27 10:12", "Worcester Heat Systems", "Worcester", "Bosch/British Gas ICS1", "ZBR 8-35A", "", "2001", "2003", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "34.7", "34.7", "", "", "88.9", "79.9", "", "58.4", "", "2", "", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.5", "98.9", "", "", "", "", "96.9"]} +{"pcdb_id": 8368, "brand_name": "Worcester", "model_name": "Greenstar HE", "model_qualifier": "ZWB 7-27A", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 55.9, "output_kw_max": 27.2, "final_year_of_manufacture": 2003, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008368", "000035", "0", "2006/Jan/17 12:55", "Worcester Heat Systems", "Worcester", "Greenstar HE", "ZWB 7-27A", "", "2001", "2003", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "27.2", "27.2", "", "", "88.1", "79.5", "", "55.9", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.9", "96.8", "", "", "", "", "95.3"]} +{"pcdb_id": 8369, "brand_name": "Worcester", "model_name": "Greenstar HE", "model_qualifier": "ZB 7-27A", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 27.2, "final_year_of_manufacture": 2003, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008369", "000035", "0", "2012/Mar/27 10:12", "Worcester Heat Systems", "Worcester", "Greenstar HE", "ZB 7-27A", "", "2001", "2003", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "27.2", "27.2", "", "", "88.1", "79.1", "", "57.8", "", "2", "", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.9", "96.8", "", "", "", "", "95.3"]} +{"pcdb_id": 8370, "brand_name": "Worcester", "model_name": "Greenstar HE Plus", "model_qualifier": "ZWBR 7-28A", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 55.9, "output_kw_max": 28.2, "final_year_of_manufacture": 2003, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008370", "000035", "0", "2006/Jan/17 12:55", "Worcester Heat Systems", "Worcester", "Greenstar HE Plus", "ZWBR 7-28A", "", "2001", "2003", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28.2", "28.2", "", "", "88.1", "79.5", "", "55.9", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.9", "96.8", "", "", "", "", "95.3"]} +{"pcdb_id": 8371, "brand_name": "Worcester", "model_name": "Greenstar HE Plus", "model_qualifier": "ZWBR 11-35A", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 56.5, "output_kw_max": 35.1, "final_year_of_manufacture": 2003, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008371", "000035", "0", "2006/Jan/17 12:55", "Worcester Heat Systems", "Worcester", "Greenstar HE Plus", "ZWBR 11-35A", "", "2001", "2003", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "35.1", "35.1", "", "", "88.9", "80.3", "", "56.5", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.5", "98.9", "", "", "", "", "96.9"]} +{"pcdb_id": 8372, "brand_name": "Grant", "model_name": "Outdoor", "model_qualifier": "Combi Mk II", "winter_efficiency_pct": 84.9, "summer_efficiency_pct": 75.4, "comparative_hot_water_efficiency_pct": 53.0, "output_kw_max": 26.37, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008372", "000048", "0", "2001/Jun/19 15:56", "Grant Engineering", "Grant", "Outdoor", "Combi Mk II", "", "1997", "current", "4", "1", "2", "2", "0", "", "", "1", "1", "2", "26.37", "26.37", "", "", "84.9", "75.4", "", "53.0", "", "2", "", "", "202", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.4", "88.0", "", "", "", "", "87.7"]} +{"pcdb_id": 8373, "brand_name": "Alpha", "model_name": "240p", "model_qualifier": "", "winter_efficiency_pct": 71.0, "summer_efficiency_pct": 61.0, "comparative_hot_water_efficiency_pct": 42.8, "output_kw_max": 23.3, "final_year_of_manufacture": 1999, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008373", "000001", "0", "2010/Sep/13 17:03", "Alpha Therm", "Alpha", "240p", "", "", "1996", "1999", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "23.3", "23.3", "", "", "71.0", "61.0", "", "42.8", "", "3", "", "", "0", "2", "2", "170", "5", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 8374, "brand_name": "Alpha", "model_name": "240xe", "model_qualifier": "", "winter_efficiency_pct": 71.0, "summer_efficiency_pct": 61.0, "comparative_hot_water_efficiency_pct": 42.8, "output_kw_max": 23.3, "final_year_of_manufacture": 1998, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008374", "000001", "0", "2010/Sep/13 17:03", "Alpha Therm", "Alpha", "240xe", "", "", "1996", "1998", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "23.3", "23.3", "", "", "71.0", "61.0", "", "42.8", "", "3", "", "", "0", "1", "2", "170", "5", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 8375, "brand_name": "Alpha", "model_name": "240xp", "model_qualifier": "", "winter_efficiency_pct": 71.0, "summer_efficiency_pct": 61.0, "comparative_hot_water_efficiency_pct": 42.8, "output_kw_max": 23.3, "final_year_of_manufacture": 1998, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008375", "000001", "0", "2010/Sep/13 17:03", "Alpha Therm", "Alpha", "240xp", "", "", "1996", "1998", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "23.3", "23.3", "", "", "71.0", "61.0", "", "42.8", "", "3", "", "", "0", "2", "2", "170", "5", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 8378, "brand_name": "Glow-worm", "model_name": "Xtramax", "model_qualifier": "A", "winter_efficiency_pct": 79.7, "summer_efficiency_pct": 70.6, "comparative_hot_water_efficiency_pct": 38.0, "output_kw_max": 27.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008378", "000207", "0", "2024/Jan/31 10:17", "Saunier Duval", "Glow-worm", "Xtramax", "A", "GC 47-047-15", "2001", "current", "1", "3", "1", "2", "0", "", "", "1", "2", "2", "27.6", "27.6", "", "", "79.7", "70.6", "", "38.0", "", "2", "", "", "106", "1", "2", "235", "15", "2", "2", "0", "42", "0", "15", "2", "60", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "83.2", "77.9", "", "", "", "", "78.9"]} +{"pcdb_id": 8379, "brand_name": "Saunier Duval", "model_name": "Isomax F28E", "model_qualifier": "A", "winter_efficiency_pct": 79.7, "summer_efficiency_pct": 70.6, "comparative_hot_water_efficiency_pct": 38.0, "output_kw_max": 27.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008379", "000206", "0", "2024/Jan/31 10:17", "Saunier Duval", "Saunier Duval", "Isomax F28E", "A", "GC 47-920-28", "2001", "current", "1", "3", "1", "2", "0", "", "", "1", "2", "2", "27.6", "27.6", "", "", "79.7", "70.6", "", "38.0", "", "2", "", "", "106", "1", "2", "235", "15", "2", "2", "0", "42", "0", "15", "2", "60", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "83.2", "77.9", "", "", "", "", "78.9"]} +{"pcdb_id": 8380, "brand_name": "Alpha", "model_name": "CB28X", "model_qualifier": "", "winter_efficiency_pct": 81.0, "summer_efficiency_pct": 70.9, "comparative_hot_water_efficiency_pct": 49.8, "output_kw_max": 28.0, "final_year_of_manufacture": 2005, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008380", "000001", "0", "2011/Sep/06 13:08", "Alpha Therm", "Alpha", "CB28X", "", "", "2001", "2005", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "28.0", "28.0", "", "", "81.0", "70.9", "", "49.8", "", "2", "", "", "104", "1", "2", "170", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "83.3", "81.5", "", "", "", "", "81.8"]} +{"pcdb_id": 8382, "brand_name": "Aquaflame", "model_name": "HE 15", "model_qualifier": "", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 15.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008382", "000039", "0", "2012/Mar/27 10:12", "Aquaflame", "Aquaflame", "HE 15", "", "", "2001", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "15", "15", "", "", "87.9", "80.1", "", "58.5", "", "2", "", "", "201", "1", "1", "100", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.6", "94.1", "", "", "", "", "93.6"]} +{"pcdb_id": 8383, "brand_name": "Aquaflame", "model_name": "HE 19", "model_qualifier": "", "winter_efficiency_pct": 87.8, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 19.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008383", "000039", "0", "2012/Mar/27 10:12", "Aquaflame", "Aquaflame", "HE 19", "", "", "2001", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "19", "19", "", "", "87.8", "80.0", "", "58.4", "", "2", "", "", "201", "1", "1", "100", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "92.0", "93.7", "", "", "", "", "93.4"]} +{"pcdb_id": 8386, "brand_name": "Aquaflame", "model_name": "HE 22", "model_qualifier": "", "winter_efficiency_pct": 87.2, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 21.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008386", "000039", "0", "2012/Mar/27 10:12", "Aquaflame", "Aquaflame", "HE 22", "", "", "2001", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "21.3", "21.3", "", "", "87.2", "79.4", "", "58.0", "", "2", "", "", "201", "1", "1", "100", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.1", "92.6", "", "", "", "", "92.3"]} +{"pcdb_id": 8387, "brand_name": "Viessmann", "model_name": "Vitodens 200", "model_qualifier": "WB2-44kW", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 44.0, "final_year_of_manufacture": 2005, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008387", "000033", "0", "2012/Mar/27 10:12", "Viessmann", "Viessmann", "Vitodens 200", "WB2-44kW", "", "", "2005", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "44.0", "44.0", "", "", "88.5", "79.5", "", "58.1", "", "2", "", "", "102", "1", "2", "72", "11", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "98.0", "", "", "", "", "96.1"]} +{"pcdb_id": 8388, "brand_name": "Viessmann", "model_name": "Vitodens 200", "model_qualifier": "WB2-66kW", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 60.0, "final_year_of_manufacture": 2005, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008388", "000033", "0", "2012/Mar/27 10:12", "Viessmann", "Viessmann", "Vitodens 200", "WB2-66kW", "", "", "2005", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "60.0", "60.0", "", "", "88.5", "79.5", "", "58.1", "", "2", "", "", "102", "1", "2", "104", "11", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "98.2", "", "", "", "", "96.2"]} +{"pcdb_id": 8389, "brand_name": "Viessmann", "model_name": "Vitodens 200", "model_qualifier": "WB2-32kW", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 32.0, "final_year_of_manufacture": 2005, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008389", "000033", "0", "2012/Mar/27 10:12", "Viessmann", "Viessmann", "Vitodens 200", "WB2-32kW", "", "", "2005", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "32.0", "32.0", "", "", "88.7", "79.7", "", "58.2", "", "2", "", "", "102", "1", "2", "148", "11", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "98.5", "", "", "", "", "96.5"]} +{"pcdb_id": 8390, "brand_name": "Viessmann", "model_name": "Vitodens 200 Combi", "model_qualifier": "WB2-24kW", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 56.4, "output_kw_max": 24.0, "final_year_of_manufacture": 2005, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008390", "000033", "0", "2006/Jan/17 12:55", "Viessmann", "Viessmann", "Vitodens 200 Combi", "WB2-24kW", "", "", "2005", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.0", "24.0", "", "", "88.7", "80.1", "", "56.4", "", "2", "", "", "104", "1", "2", "130", "11", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "98.7", "", "", "", "", "96.6"]} +{"pcdb_id": 8391, "brand_name": "Viessmann", "model_name": "Vitodens 200", "model_qualifier": "WB2-24kW", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 24.0, "final_year_of_manufacture": 2005, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008391", "000033", "0", "2012/Mar/27 10:12", "Viessmann", "Viessmann", "Vitodens 200", "WB2-24kW", "", "", "2005", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24.0", "24.0", "", "", "88.7", "79.7", "", "58.2", "", "2", "", "", "102", "1", "2", "130", "11", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "98.7", "", "", "", "", "96.6"]} +{"pcdb_id": 8392, "brand_name": "Viessmann", "model_name": "Vitodens 200", "model_qualifier": "WB2-11kW", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 11.0, "final_year_of_manufacture": 2005, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008392", "000033", "0", "2012/Mar/27 10:12", "Viessmann", "Viessmann", "Vitodens 200", "WB2-11kW", "", "", "2005", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "11.0", "11.0", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "101", "11", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.7", "97.8", "", "", "", "", "95.9"]} +{"pcdb_id": 8393, "brand_name": "Viessmann", "model_name": "Vitopend 100 Combi", "model_qualifier": "WH1-24kW", "winter_efficiency_pct": 76.2, "summer_efficiency_pct": 66.1, "comparative_hot_water_efficiency_pct": 46.4, "output_kw_max": 24.0, "final_year_of_manufacture": 2005, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008393", "000033", "0", "2006/Jan/17 12:55", "Viessmann", "Viessmann", "Vitopend 100 Combi", "WH1-24kW", "", "", "2005", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "24.0", "24.0", "", "", "76.2", "66.1", "", "46.4", "", "2", "", "", "104", "1", "2", "143", "7", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "80.2", "74.5", "", "", "", "", "75.6"]} +{"pcdb_id": 8394, "brand_name": "Ravenheat", "model_name": "RSF 100ET*", "model_qualifier": "", "winter_efficiency_pct": 79.8, "summer_efficiency_pct": 69.7, "comparative_hot_water_efficiency_pct": 49.0, "output_kw_max": 29.66, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008394", "000026", "0", "2015/Sep/03 13:02", "Ravenheat", "Ravenheat", "RSF 100ET*", "", "G.C No 47 581 26A", "2001", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "29.66", "29.66", "", "", "79.8", "69.7", "", "49.0", "", "2", "", "", "104", "1", "2", "160", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.5", "80.5", "", "", "", "", "80.7"]} +{"pcdb_id": 8395, "brand_name": "Ravenheat", "model_name": "RSF 100E*", "model_qualifier": "", "winter_efficiency_pct": 79.8, "summer_efficiency_pct": 69.7, "comparative_hot_water_efficiency_pct": 49.0, "output_kw_max": 29.7, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008395", "000026", "0", "2006/Jan/17 12:31", "Ravenheat", "Ravenheat", "RSF 100E*", "", "G.C. No 47 581 25A", "2001", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "29.7", "29.7", "", "", "79.8", "69.7", "", "49.0", "", "2", "", "", "104", "1", "2", "160", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.5", "80.5", "", "", "", "", "80.7"]} +{"pcdb_id": 8396, "brand_name": "Ravenheat", "model_name": "RSF 84E*", "model_qualifier": "", "winter_efficiency_pct": 79.7, "summer_efficiency_pct": 69.6, "comparative_hot_water_efficiency_pct": 48.9, "output_kw_max": 24.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008396", "000026", "0", "2006/Jan/17 12:31", "Ravenheat", "Ravenheat", "RSF 84E*", "", "G.C. No 47 581 27A", "2001", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "24.6", "24.6", "", "", "79.7", "69.6", "", "48.9", "", "2", "", "", "104", "1", "2", "160", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.4", "79.4", "", "", "", "", "79.9"]} +{"pcdb_id": 8397, "brand_name": "Ravenheat", "model_name": "RSF 84ET*", "model_qualifier": "", "winter_efficiency_pct": 79.7, "summer_efficiency_pct": 69.6, "comparative_hot_water_efficiency_pct": 48.9, "output_kw_max": 24.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008397", "000026", "0", "2006/Jan/17 12:31", "Ravenheat", "Ravenheat", "RSF 84ET*", "", "G.C No 47 581 28A", "2001", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "24.6", "24.6", "", "", "79.7", "69.6", "", "48.9", "", "2", "", "", "104", "1", "2", "160", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.4", "79.4", "", "", "", "", "79.9"]} +{"pcdb_id": 8398, "brand_name": "Ravenheat", "model_name": "RSF 84ET*", "model_qualifier": "", "winter_efficiency_pct": 81.5, "summer_efficiency_pct": 71.4, "comparative_hot_water_efficiency_pct": 50.2, "output_kw_max": 24.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008398", "000026", "0", "2006/Jan/17 12:31", "Ravenheat", "Ravenheat", "RSF 84ET*", "", "G.C. No 47 581 28A", "2001", "current", "2", "2", "1", "2", "0", "", "", "1", "2", "2", "24.6", "24.6", "", "", "81.5", "71.4", "", "50.2", "", "2", "0", "", "104", "1", "2", "160", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "84.2", "81.1", "", "", "", "", "81.7"]} +{"pcdb_id": 8399, "brand_name": "Ravenheat", "model_name": "RSF 84E*", "model_qualifier": "", "winter_efficiency_pct": 81.5, "summer_efficiency_pct": 71.4, "comparative_hot_water_efficiency_pct": 50.2, "output_kw_max": 24.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008399", "000026", "0", "2006/Jan/17 12:31", "Ravenheat", "Ravenheat", "RSF 84E*", "", "G.C No 47 581 27A", "2001", "current", "2", "2", "1", "2", "0", "", "", "1", "2", "2", "24.6", "24.6", "", "", "81.5", "71.4", "", "50.2", "", "2", "0", "", "104", "1", "2", "160", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "84.2", "81.1", "", "", "", "", "81.7"]} +{"pcdb_id": 8400, "brand_name": "Ravenheat", "model_name": "RSF 100ET*", "model_qualifier": "", "winter_efficiency_pct": 81.6, "summer_efficiency_pct": 71.5, "comparative_hot_water_efficiency_pct": 50.3, "output_kw_max": 29.7, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008400", "000026", "0", "2006/Jan/17 12:31", "Ravenheat", "Ravenheat", "RSF 100ET*", "", "G.C No 47 581 26A", "2001", "current", "2", "2", "1", "2", "0", "", "", "1", "2", "2", "29.7", "29.7", "", "", "81.6", "71.5", "", "50.3", "", "2", "0", "", "104", "1", "2", "160", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "83.4", "82.3", "", "", "", "", "82.5"]} +{"pcdb_id": 8401, "brand_name": "Ravenheat", "model_name": "RSF 100E*", "model_qualifier": "", "winter_efficiency_pct": 81.6, "summer_efficiency_pct": 71.5, "comparative_hot_water_efficiency_pct": 50.3, "output_kw_max": 29.7, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008401", "000026", "0", "2006/Jan/17 12:31", "Ravenheat", "Ravenheat", "RSF 100E*", "", "G.C No 47 581 25A", "2001", "current", "2", "2", "1", "2", "0", "", "", "1", "2", "2", "29.7", "29.7", "", "", "81.6", "71.5", "", "50.3", "", "2", "0", "", "104", "1", "2", "160", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "83.4", "82.3", "", "", "", "", "82.5"]} +{"pcdb_id": 8402, "brand_name": "Grant", "model_name": "Euroflame", "model_qualifier": "Kitchen/Utility 90-120", "winter_efficiency_pct": 85.5, "summer_efficiency_pct": 73.8, "comparative_hot_water_efficiency_pct": 53.9, "output_kw_max": 35.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008402", "000048", "0", "2012/Mar/27 10:12", "Grant Engineering", "Grant", "Euroflame", "Kitchen/Utility 90-120", "", "2001", "current", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "26.4", "35.2", "", "", "85.5", "73.8", "", "53.9", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.2", "85.9", "", "", "", "", "85.8"]} +{"pcdb_id": 8403, "brand_name": "Grant", "model_name": "Euroflame", "model_qualifier": "90-120 System Kitchen Utility", "winter_efficiency_pct": 85.5, "summer_efficiency_pct": 73.8, "comparative_hot_water_efficiency_pct": 53.9, "output_kw_max": 35.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008403", "000048", "0", "2012/Mar/27 10:12", "Grant Engineering", "Grant", "Euroflame", "90-120 System Kitchen Utility", "", "2001", "current", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "26.4", "35.2", "", "", "85.5", "73.8", "", "53.9", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.2", "85.9", "", "", "", "", "85.8"]} +{"pcdb_id": 8404, "brand_name": "Grant", "model_name": "Euroflame", "model_qualifier": "90-120 Boilerhouse", "winter_efficiency_pct": 85.5, "summer_efficiency_pct": 73.8, "comparative_hot_water_efficiency_pct": 53.9, "output_kw_max": 35.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008404", "000048", "0", "2012/Mar/27 10:12", "Grant Engineering", "Grant", "Euroflame", "90-120 Boilerhouse", "", "2001", "current", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "26.4", "35.2", "", "", "85.5", "73.8", "", "53.9", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.2", "85.9", "", "", "", "", "85.8"]} +{"pcdb_id": 8405, "brand_name": "Grant", "model_name": "Euroflame", "model_qualifier": "90-120 Outdoor", "winter_efficiency_pct": 85.5, "summer_efficiency_pct": 73.8, "comparative_hot_water_efficiency_pct": 53.9, "output_kw_max": 35.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008405", "000048", "0", "2012/Mar/27 10:12", "Grant Engineering", "Grant", "Euroflame", "90-120 Outdoor", "", "2001", "current", "4", "1", "2", "1", "0", "", "", "1", "2", "2", "26.4", "35.2", "", "", "85.5", "73.8", "", "53.9", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.2", "85.9", "", "", "", "", "85.8"]} +{"pcdb_id": 8406, "brand_name": "Baxi", "model_name": "Solo 3 PFL", "model_qualifier": "30", "winter_efficiency_pct": 80.3, "summer_efficiency_pct": 70.2, "comparative_hot_water_efficiency_pct": 51.3, "output_kw_max": 10.99, "final_year_of_manufacture": 2008, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008406", "000005", "0", "2012/Mar/27 10:12", "Baxi UK", "Baxi", "Solo 3 PFL", "30", "GC No. 41-075-20", "2001", "2008", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "10.99", "10.99", "", "", "80.3", "70.2", "", "51.3", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.7", "81.1", "", "", "", "", "81.4"]} +{"pcdb_id": 8407, "brand_name": "Baxi", "model_name": "Solo 3 PFL", "model_qualifier": "40", "winter_efficiency_pct": 79.3, "summer_efficiency_pct": 69.2, "comparative_hot_water_efficiency_pct": 50.6, "output_kw_max": 14.65, "final_year_of_manufacture": 2008, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008407", "000005", "0", "2012/Mar/27 10:12", "Baxi UK", "Baxi", "Solo 3 PFL", "40", "GC No. 41-075-21", "2001", "2008", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "14.65", "14.65", "", "", "79.3", "69.2", "", "50.6", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.5", "80.3", "", "", "", "", "80.5"]} +{"pcdb_id": 8408, "brand_name": "Baxi", "model_name": "Solo 3 PFL", "model_qualifier": "50", "winter_efficiency_pct": 78.9, "summer_efficiency_pct": 68.8, "comparative_hot_water_efficiency_pct": 50.3, "output_kw_max": 18.3, "final_year_of_manufacture": 2010, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008408", "000005", "0", "2012/Mar/27 10:12", "Baxi UK", "Baxi", "Solo 3 PFL", "50", "GC No. 41-075-22", "2001", "2010", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "18.3", "18.3", "", "", "78.9", "68.8", "", "50.3", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "80.9", "80.1", "", "", "", "", "80.3"]} +{"pcdb_id": 8409, "brand_name": "Baxi", "model_name": "Solo 3 PFL", "model_qualifier": "60", "winter_efficiency_pct": 79.4, "summer_efficiency_pct": 69.3, "comparative_hot_water_efficiency_pct": 50.7, "output_kw_max": 22.0, "final_year_of_manufacture": 2010, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008409", "000005", "0", "2012/Mar/27 10:12", "Baxi UK", "Baxi", "Solo 3 PFL", "60", "GC No. 41-075-23", "2001", "2010", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "22", "22.0", "", "", "79.4", "69.3", "", "50.7", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.5", "80.5", "", "", "", "", "80.7"]} +{"pcdb_id": 8410, "brand_name": "Baxi", "model_name": "Solo 3 PFL", "model_qualifier": "70", "winter_efficiency_pct": 79.1, "summer_efficiency_pct": 69.0, "comparative_hot_water_efficiency_pct": 50.4, "output_kw_max": 25.64, "final_year_of_manufacture": 2008, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008410", "000005", "0", "2012/Mar/27 10:12", "Baxi UK", "Baxi", "Solo 3 PFL", "70", "GC No. 41-075-24", "2001", "2008", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "25.64", "25.64", "", "", "79.1", "69.0", "", "50.4", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.1", "80.3", "", "", "", "", "80.4"]} +{"pcdb_id": 8411, "brand_name": "Baxi", "model_name": "Solo 3 PFL System", "model_qualifier": "30", "winter_efficiency_pct": 80.3, "summer_efficiency_pct": 70.2, "comparative_hot_water_efficiency_pct": 51.3, "output_kw_max": 10.99, "final_year_of_manufacture": 2006, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008411", "000005", "0", "2012/Mar/27 10:12", "Baxi UK", "Baxi", "Solo 3 PFL System", "30", "GC No. 41-075-25", "2001", "2006", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "10.99", "10.99", "", "", "80.3", "70.2", "", "51.3", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.7", "81.1", "", "", "", "", "81.4"]} +{"pcdb_id": 8412, "brand_name": "Baxi", "model_name": "Solo 3 PFL System", "model_qualifier": "40", "winter_efficiency_pct": 79.3, "summer_efficiency_pct": 69.2, "comparative_hot_water_efficiency_pct": 50.6, "output_kw_max": 14.65, "final_year_of_manufacture": 2006, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008412", "000005", "0", "2012/Mar/27 10:12", "Baxi UK", "Baxi", "Solo 3 PFL System", "40", "GC No. 41-075-26", "2001", "2006", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "14.65", "14.65", "", "", "79.3", "69.2", "", "50.6", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.5", "80.3", "", "", "", "", "80.5"]} +{"pcdb_id": 8413, "brand_name": "Baxi", "model_name": "Solo 3 PFL System", "model_qualifier": "50", "winter_efficiency_pct": 78.9, "summer_efficiency_pct": 68.8, "comparative_hot_water_efficiency_pct": 50.3, "output_kw_max": 18.3, "final_year_of_manufacture": 2006, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008413", "000005", "0", "2012/Mar/27 10:12", "Baxi UK", "Baxi", "Solo 3 PFL System", "50", "GC No. 41-075-27", "2001", "2006", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "18.3", "18.3", "", "", "78.9", "68.8", "", "50.3", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "80.9", "80.1", "", "", "", "", "80.3"]} +{"pcdb_id": 8414, "brand_name": "Baxi", "model_name": "Solo 3 PFL System", "model_qualifier": "60", "winter_efficiency_pct": 79.4, "summer_efficiency_pct": 69.3, "comparative_hot_water_efficiency_pct": 50.7, "output_kw_max": 22.0, "final_year_of_manufacture": 2006, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008414", "000005", "0", "2012/Mar/27 10:12", "Baxi UK", "Baxi", "Solo 3 PFL System", "60", "GC No. 41-075-28", "2001", "2006", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "22", "22.0", "", "", "79.4", "69.3", "", "50.7", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.5", "80.5", "", "", "", "", "80.7"]} +{"pcdb_id": 8415, "brand_name": "Baxi", "model_name": "Solo 3 PFL System", "model_qualifier": "70", "winter_efficiency_pct": 79.1, "summer_efficiency_pct": 69.0, "comparative_hot_water_efficiency_pct": 50.4, "output_kw_max": 25.64, "final_year_of_manufacture": 2006, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008415", "000005", "0", "2012/Mar/27 10:12", "Baxi UK", "Baxi", "Solo 3 PFL System", "70", "GC No. 41-075-29", "2001", "2006", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "25.64", "25.64", "", "", "79.1", "69.0", "", "50.4", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.1", "80.3", "", "", "", "", "80.4"]} +{"pcdb_id": 8416, "brand_name": "Grant", "model_name": "Multipass", "model_qualifier": "System 50-70", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 20.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008416", "000048", "0", "2012/Mar/27 10:12", "Grant Engineering", "Grant", "Multipass", "System 50-70", "", "1998", "current", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "14.6", "20.5", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "90.0", "87.6", "", "", "", "", "88.1"]} +{"pcdb_id": 8417, "brand_name": "Grant", "model_name": "Multipass", "model_qualifier": "System 70-90", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 26.37, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008417", "000048", "0", "2012/Mar/27 10:12", "Grant Engineering", "Grant", "Multipass", "System 70-90", "", "1998", "current", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "20.52", "26.37", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "89.8", "87.3", "", "", "", "", "87.8"]} +{"pcdb_id": 8418, "brand_name": "Grant", "model_name": "Multipass", "model_qualifier": "System 90-110", "winter_efficiency_pct": 86.5, "summer_efficiency_pct": 74.8, "comparative_hot_water_efficiency_pct": 54.7, "output_kw_max": 32.24, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008418", "000048", "0", "2012/Mar/27 10:12", "Grant Engineering", "Grant", "Multipass", "System 90-110", "", "1998", "current", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "26.37", "32.24", "", "", "86.5", "74.8", "", "54.7", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.9", "86.9", "", "", "", "", "87.1"]} +{"pcdb_id": 8419, "brand_name": "Grant", "model_name": "Multipass", "model_qualifier": "System 110-140", "winter_efficiency_pct": 86.5, "summer_efficiency_pct": 74.8, "comparative_hot_water_efficiency_pct": 54.7, "output_kw_max": 41.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008419", "000048", "0", "2012/Mar/27 10:12", "Grant Engineering", "Grant", "Multipass", "System 110-140", "", "1998", "current", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "32.24", "41.0", "", "", "86.5", "74.8", "", "54.7", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.9", "86.9", "", "", "", "", "87.1"]} +{"pcdb_id": 8420, "brand_name": "Grant", "model_name": "Multipass", "model_qualifier": "Outdoor 110-140", "winter_efficiency_pct": 86.5, "summer_efficiency_pct": 74.8, "comparative_hot_water_efficiency_pct": 54.7, "output_kw_max": 41.03, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008420", "000048", "0", "2012/Mar/27 10:12", "Grant Engineering", "Grant", "Multipass", "Outdoor 110-140", "", "1998", "current", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "32.24", "41.03", "", "", "86.5", "74.8", "", "54.7", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.9", "86.9", "", "", "", "", "87.1"]} +{"pcdb_id": 8421, "brand_name": "Vaillant", "model_name": "Ecomax", "model_qualifier": "828/2E", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 56.0, "output_kw_max": 22.4, "final_year_of_manufacture": 2010, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008421", "000031", "0", "2010/Jan/28 08:31", "Vaillant", "Vaillant", "Ecomax", "828/2E", "VUW 286/2E-C", "2001", "2010", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "22.4", "22.4", "", "", "88.2", "79.6", "", "56.0", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.0", "96.5", "", "", "", "", "95.3"]} +{"pcdb_id": 8422, "brand_name": "Vaillant", "model_name": "Ecomax", "model_qualifier": "824/2E", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 56.0, "output_kw_max": 18.4, "final_year_of_manufacture": 2010, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008422", "000031", "0", "2010/Jan/28 08:17", "Vaillant", "Vaillant", "Ecomax", "824/2E", "VUW 246/2E-C", "2001", "2010", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "18.4", "18.4", "", "", "88.3", "79.7", "", "56.0", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.0", "96.7", "", "", "", "", "95.4"]} +{"pcdb_id": 8423, "brand_name": "Vaillant", "model_name": "Ecomax", "model_qualifier": "622/2E", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 22.4, "final_year_of_manufacture": 2010, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008423", "000031", "0", "2012/Mar/27 10:12", "Vaillant", "Vaillant", "Ecomax", "622/2E", "VU GB 246/2E-C", "2001", "2010", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "22.4", "22.4", "", "", "88.2", "79.2", "", "57.9", "", "2", "", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.0", "96.5", "", "", "", "", "95.3"]} +{"pcdb_id": 8424, "brand_name": "Vaillant", "model_name": "Ecomax", "model_qualifier": "618/2E", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 18.4, "final_year_of_manufacture": 2010, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008424", "000031", "0", "2012/Mar/27 10:12", "Vaillant", "Vaillant", "Ecomax", "618/2E", "VU GB 196/2E", "2001", "2010", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18.4", "18.4", "", "", "88.3", "79.3", "", "57.9", "", "2", "", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.0", "96.7", "", "", "", "", "95.4"]} +{"pcdb_id": 8425, "brand_name": "Vaillant", "model_name": "Ecomax", "model_qualifier": "613/2E", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 13.5, "final_year_of_manufacture": 2010, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008425", "000031", "0", "2012/Mar/27 10:12", "Vaillant", "Vaillant", "Ecomax", "613/2E", "VU GB 126/2E", "2001", "2010", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "13.5", "13.5", "", "", "88.2", "79.2", "", "57.9", "", "2", "", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.0", "96.6", "", "", "", "", "95.3"]} +{"pcdb_id": 8426, "brand_name": "Ferroli", "model_name": "Arena 30 A", "model_qualifier": "Mk2", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 32.4, "final_year_of_manufacture": 2005, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008426", "000097", "0", "2012/Mar/27 10:12", "Ferroli SpA", "Ferroli", "Arena 30 A", "Mk2", "", "2001", "2005", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "32.4", "32.4", "", "", "88.2", "79.2", "", "57.8", "", "2", "", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.4", "97.0", "", "", "", "", "95.4"]} +{"pcdb_id": 8427, "brand_name": "Ferroli", "model_name": "Arena 30 C", "model_qualifier": "Mk2", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 55.9, "output_kw_max": 32.4, "final_year_of_manufacture": 2005, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008427", "000097", "0", "2009/Apr/28 16:15", "Ferroli SpA", "Ferroli", "Arena 30 C", "Mk2", "", "2001", "2005", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "32.4", "32.4", "", "", "88.2", "79.6", "", "55.9", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.4", "97.0", "", "", "", "", "95.4"]} +{"pcdb_id": 8429, "brand_name": "Boulter", "model_name": "Classic", "model_qualifier": "50/70 A System", "winter_efficiency_pct": 86.1, "summer_efficiency_pct": 74.4, "comparative_hot_water_efficiency_pct": 54.3, "output_kw_max": 20.5, "final_year_of_manufacture": 2005, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008429", "000041", "0", "2012/Mar/27 10:12", "Boulter Boilers", "Boulter", "Classic", "50/70 A System", "", "2001", "2005", "4", "1", "1", "1", "0", "", "", "1", "3", "2", "14.5", "20.5", "", "", "86.1", "74.4", "", "54.3", "", "2", "", "", "201", "1", "1", "115", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.6", "86.5", "", "", "", "", "86.3"]} +{"pcdb_id": 8430, "brand_name": "Boulter", "model_name": "Camray 5", "model_qualifier": "Combi 55", "winter_efficiency_pct": 84.7, "summer_efficiency_pct": 76.6, "comparative_hot_water_efficiency_pct": 36.0, "output_kw_max": 16.12, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 1, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008430", "000041", "0", "2024/Jan/31 10:17", "Boulter Boilers", "Boulter", "Camray 5", "Combi 55", "", "2001", "current", "4", "1", "1", "2", "0", "", "", "1", "3", "2", "", "16.12", "", "", "84.7", "76.6", "", "36.0", "", "2", "", "", "203", "1", "1", "155", "0", "1", "1", "0", "40", "0", "15", "3", "82", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.0", "87.0", "", "", "", "", "87.0"]} +{"pcdb_id": 8431, "brand_name": "Boulter", "model_name": "Classic", "model_qualifier": "50/70 A", "winter_efficiency_pct": 86.1, "summer_efficiency_pct": 74.4, "comparative_hot_water_efficiency_pct": 54.3, "output_kw_max": 20.5, "final_year_of_manufacture": 2005, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008431", "000041", "0", "2012/Mar/27 10:12", "Boulter Boilers", "Boulter", "Classic", "50/70 A", "", "2001", "2005", "4", "1", "1", "1", "0", "", "", "1", "3", "2", "14.5", "20.5", "", "", "86.1", "74.4", "", "54.3", "", "2", "", "", "201", "1", "1", "115", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.6", "86.5", "", "", "", "", "86.3"]} +{"pcdb_id": 8435, "brand_name": "Boulter", "model_name": "Camray 5 Wall Hung", "model_qualifier": "50/70 Internal", "winter_efficiency_pct": 86.4, "summer_efficiency_pct": 74.7, "comparative_hot_water_efficiency_pct": 54.6, "output_kw_max": 20.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008435", "000041", "0", "2012/Mar/27 10:12", "Boulter Boilers", "Boulter", "Camray 5 Wall Hung", "50/70 Internal", "", "2001", "current", "4", "2", "1", "1", "0", "", "", "1", "3", "2", "14.5", "20.5", "", "", "86.4", "74.7", "", "54.6", "", "2", "", "", "201", "1", "1", "170", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.6", "87.7", "", "", "", "", "87.3"]} +{"pcdb_id": 8437, "brand_name": "Ideal", "model_name": "icos system", "model_qualifier": "m3080", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 23.4, "final_year_of_manufacture": 2004, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008437", "000008", "0", "2012/Mar/27 10:12", "Ideal Boilers", "Ideal", "icos system", "m3080", "41-391-52", "2001", "2004", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "23.4", "23.4", "", "", "88.1", "79.1", "", "57.8", "", "2", "", "", "102", "1", "2", "148", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "97.1", "", "", "", "", "95.4"]} +{"pcdb_id": 8438, "brand_name": "Ideal", "model_name": "icos", "model_qualifier": "m3080", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 23.4, "final_year_of_manufacture": 2004, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008438", "000008", "0", "2012/Mar/27 10:12", "Ideal boilers", "Ideal", "icos", "m3080", "41-391-49", "2001", "2004", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "23.4", "23.4", "", "", "88.1", "79.1", "", "57.8", "", "2", "", "", "102", "1", "2", "38", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "97.1", "", "", "", "", "95.4"]} +{"pcdb_id": 8439, "brand_name": "Ideal", "model_name": "isar", "model_qualifier": "m30100", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 55.9, "output_kw_max": 23.4, "final_year_of_manufacture": 2004, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008439", "000008", "0", "2006/Jan/17 12:55", "Ideal boilers", "Ideal", "isar", "m30100", "47-348-15", "2001", "2004", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "23.4", "23.4", "", "", "88.1", "79.5", "", "55.9", "", "2", "", "", "104", "1", "2", "148", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "97.1", "", "", "", "", "95.4"]} +{"pcdb_id": 8440, "brand_name": "Potterton", "model_name": "Performa", "model_qualifier": "24", "winter_efficiency_pct": 79.5, "summer_efficiency_pct": 69.4, "comparative_hot_water_efficiency_pct": 48.8, "output_kw_max": 24.0, "final_year_of_manufacture": 2006, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008440", "000005", "0", "2006/Nov/21 09:59", "Baxi Potterton", "Potterton", "Performa", "24", "47-393-06", "2001", "2006", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "24", "24", "", "", "79.5", "69.4", "", "48.8", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.2", "79.2", "", "", "", "", "79.8"]} +{"pcdb_id": 8441, "brand_name": "Potterton", "model_name": "Performa", "model_qualifier": "28", "winter_efficiency_pct": 79.0, "summer_efficiency_pct": 68.9, "comparative_hot_water_efficiency_pct": 48.5, "output_kw_max": 29.4, "final_year_of_manufacture": 2011, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008441", "000005", "0", "2013/May/07 10:03", "Baxi Potterton", "Potterton", "Performa", "28", "47-393-07", "2001", "2011", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "29.4", "29.4", "", "", "79.0", "68.9", "", "48.5", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.2", "79.3", "", "", "", "", "79.6"]} +{"pcdb_id": 8442, "brand_name": "Potterton", "model_name": "Performa", "model_qualifier": "28i", "winter_efficiency_pct": 79.0, "summer_efficiency_pct": 68.9, "comparative_hot_water_efficiency_pct": 48.5, "output_kw_max": 29.4, "final_year_of_manufacture": 2006, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008442", "000005", "0", "2006/Nov/21 10:05", "Baxi Potterton", "Potterton", "Performa", "28i", "47-393-08", "2001", "2006", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "29.4", "29.4", "", "", "79.0", "68.9", "", "48.5", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.2", "79.3", "", "", "", "", "79.6"]} +{"pcdb_id": 8443, "brand_name": "Boulter", "model_name": "Camray 5", "model_qualifier": "65/90A", "winter_efficiency_pct": 86.1, "summer_efficiency_pct": 74.4, "comparative_hot_water_efficiency_pct": 54.3, "output_kw_max": 26.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008443", "000041", "0", "2012/Mar/27 10:12", "Boulter Boilers", "Boulter", "Camray 5", "65/90A", "", "2001", "current", "4", "1", "1", "1", "0", "", "", "1", "3", "2", "19", "26.4", "", "", "86.1", "74.4", "", "54.3", "", "2", "", "", "201", "1", "1", "145", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.0", "88.2", "", "", "", "", "87.6"]} +{"pcdb_id": 8445, "brand_name": "Boulter", "model_name": "Camray 5", "model_qualifier": "65/90A Utility", "winter_efficiency_pct": 86.1, "summer_efficiency_pct": 74.4, "comparative_hot_water_efficiency_pct": 54.3, "output_kw_max": 26.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008445", "000041", "0", "2012/Mar/27 10:12", "Boulter Boilers", "Boulter", "Camray 5", "65/90A Utility", "", "2001", "current", "4", "1", "1", "1", "0", "", "", "1", "3", "2", "19", "26.4", "", "", "86.1", "74.4", "", "54.3", "", "2", "", "", "201", "1", "1", "145", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.0", "88.2", "", "", "", "", "87.6"]} +{"pcdb_id": 8447, "brand_name": "Boulter", "model_name": "Camray 5", "model_qualifier": "65/90A System", "winter_efficiency_pct": 86.1, "summer_efficiency_pct": 74.4, "comparative_hot_water_efficiency_pct": 54.3, "output_kw_max": 26.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008447", "000041", "0", "2012/Mar/27 10:12", "Boulter Boilers", "Boulter", "Camray 5", "65/90A System", "", "2001", "current", "4", "1", "1", "1", "0", "", "", "1", "3", "2", "19", "26.4", "", "", "86.1", "74.4", "", "54.3", "", "2", "", "", "201", "1", "1", "145", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.0", "88.2", "", "", "", "", "87.6"]} +{"pcdb_id": 8449, "brand_name": "Boulter", "model_name": "Bonus", "model_qualifier": "65/90A", "winter_efficiency_pct": 86.1, "summer_efficiency_pct": 74.4, "comparative_hot_water_efficiency_pct": 54.3, "output_kw_max": 26.4, "final_year_of_manufacture": 2005, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008449", "000041", "0", "2012/Mar/27 10:12", "Boulter Boilers", "Boulter", "Bonus", "65/90A", "", "2001", "2005", "4", "1", "1", "1", "0", "", "", "1", "3", "2", "19", "26.4", "", "", "86.1", "74.4", "", "54.3", "", "2", "", "", "201", "1", "1", "145", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.0", "88.2", "", "", "", "", "87.6"]} +{"pcdb_id": 8451, "brand_name": "Boulter", "model_name": "Camray 5", "model_qualifier": "Combi 90A", "winter_efficiency_pct": 84.2, "summer_efficiency_pct": 76.1, "comparative_hot_water_efficiency_pct": 35.7, "output_kw_max": 26.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 1, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008451", "000041", "0", "2024/Jan/31 10:17", "Boulter Boilers", "Boulter", "Camray 5", "Combi 90A", "", "2001", "current", "4", "1", "1", "2", "0", "", "", "1", "3", "2", "26.4", "26.4", "", "", "84.2", "76.1", "", "35.7", "", "2", "", "", "203", "1", "1", "145", "0", "1", "1", "0", "40", "0", "15", "3", "82", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.0", "88.2", "", "", "", "", "87.6"]} +{"pcdb_id": 8453, "brand_name": "Boulter", "model_name": "Camray 5", "model_qualifier": "Combi 70A", "winter_efficiency_pct": 84.2, "summer_efficiency_pct": 76.1, "comparative_hot_water_efficiency_pct": 35.7, "output_kw_max": 20.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 1, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008453", "000041", "0", "2024/Jan/31 10:17", "Boulter Boilers", "Boulter", "Camray 5", "Combi 70A", "", "2001", "current", "4", "1", "1", "2", "0", "", "", "1", "3", "2", "20.5", "20.5", "", "", "84.2", "76.1", "", "35.7", "", "2", "", "", "203", "1", "1", "145", "0", "1", "1", "0", "40", "0", "15", "3", "82", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.0", "88.2", "", "", "", "", "87.6"]} +{"pcdb_id": 8455, "brand_name": "Boulter", "model_name": "Classic", "model_qualifier": "70/90A", "winter_efficiency_pct": 85.8, "summer_efficiency_pct": 74.1, "comparative_hot_water_efficiency_pct": 54.1, "output_kw_max": 26.4, "final_year_of_manufacture": 2005, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008455", "000041", "0", "2012/Mar/27 10:12", "Boulter Boilers", "Boulter", "Classic", "70/90A", "", "2001", "2005", "4", "1", "1", "1", "0", "", "", "1", "3", "2", "20.5", "26.4", "", "", "85.8", "74.1", "", "54.1", "", "2", "", "", "201", "1", "1", "115", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "84.9", "86.8", "", "", "", "", "86.4"]} +{"pcdb_id": 8457, "brand_name": "Boulter", "model_name": "Classic", "model_qualifier": "70/90A System", "winter_efficiency_pct": 85.8, "summer_efficiency_pct": 74.1, "comparative_hot_water_efficiency_pct": 54.1, "output_kw_max": 26.4, "final_year_of_manufacture": 2005, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008457", "000041", "0", "2012/Mar/27 10:12", "Boulter Boilers", "Boulter", "Classic", "70/90A System", "", "2001", "2005", "4", "1", "1", "1", "0", "", "", "1", "3", "2", "20.5", "26.4", "", "", "85.8", "74.1", "", "54.1", "", "2", "", "", "201", "1", "1", "115", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "84.9", "86.8", "", "", "", "", "86.4"]} +{"pcdb_id": 8460, "brand_name": "Boulter", "model_name": "Camray 5", "model_qualifier": "150/200G", "winter_efficiency_pct": 86.6, "summer_efficiency_pct": 74.9, "comparative_hot_water_efficiency_pct": 54.7, "output_kw_max": 58.6, "final_year_of_manufacture": 2005, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008460", "000041", "0", "2012/Mar/27 10:12", "Boulter Boilers", "Boulter", "Camray 5", "150/200G", "", "2000", "2005", "4", "1", "1", "1", "0", "", "", "1", "3", "2", "43.9", "58.6", "", "", "86.6", "74.9", "", "54.7", "", "2", "", "", "201", "1", "1", "150", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.2", "87.0", "", "", "", "", "87.1"]} +{"pcdb_id": 8461, "brand_name": "Boulter", "model_name": "Classic", "model_qualifier": "95/130 System", "winter_efficiency_pct": 86.6, "summer_efficiency_pct": 74.9, "comparative_hot_water_efficiency_pct": 54.7, "output_kw_max": 38.1, "final_year_of_manufacture": 2005, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008461", "000041", "0", "2012/Mar/27 10:12", "Boulter Boilers", "Boulter", "Classic", "95/130 System", "", "2000", "2005", "4", "1", "1", "1", "0", "", "", "1", "3", "2", "27.8", "38.1", "", "", "86.6", "74.9", "", "54.7", "", "2", "", "", "201", "1", "1", "145", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.0", "88.9", "", "", "", "", "88.4"]} +{"pcdb_id": 8463, "brand_name": "Chaffoteaux et Maury", "model_name": "Britony Combi SE80", "model_qualifier": "Atac 24FF", "winter_efficiency_pct": 79.6, "summer_efficiency_pct": 69.5, "comparative_hot_water_efficiency_pct": 48.9, "output_kw_max": 24.0, "final_year_of_manufacture": 2007, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008463", "000010", "0", "2007/Jun/18 09:15", "Chaffoteaux et Maury", "Chaffoteaux et Maury", "Britony Combi SE80", "Atac 24FF", "GC No 47 980 16", "2001", "2007", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "24", "24", "", "", "79.6", "69.5", "", "48.9", "", "2", "", "", "104", "1", "2", "150", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.6", "78.9", "", "", "", "", "79.6"]} +{"pcdb_id": 8464, "brand_name": "Chaffoteaux et Maury", "model_name": "Britony Combi SE100", "model_qualifier": "Atac 28FF", "winter_efficiency_pct": 79.3, "summer_efficiency_pct": 69.2, "comparative_hot_water_efficiency_pct": 48.7, "output_kw_max": 28.0, "final_year_of_manufacture": 2007, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008464", "000010", "0", "2007/Jun/18 09:16", "Chaffoteaux et Maury", "Chaffoteaux et Maury", "Britony Combi SE100", "Atac 28FF", "GC No 47 980 17", "2001", "2007", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "28", "28", "", "", "79.3", "69.2", "", "48.7", "", "2", "", "", "104", "1", "2", "150", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.5", "78.5", "", "", "", "", "79.2"]} +{"pcdb_id": 8465, "brand_name": "Biasi", "model_name": "Parva", "model_qualifier": "M90 28S", "winter_efficiency_pct": 79.2, "summer_efficiency_pct": 69.1, "comparative_hot_water_efficiency_pct": 48.6, "output_kw_max": 28.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008465", "000208", "0", "2006/Jan/17 12:31", "Biasi SpA", "Biasi", "Parva", "M90 28S", "47-970-14", "2001", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "28", "28", "", "", "79.2", "69.1", "", "48.6", "", "2", "", "", "104", "1", "2", "170", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.2", "78.6", "", "", "", "", "79.3"]} +{"pcdb_id": 8466, "brand_name": "Biasi", "model_name": "Parva", "model_qualifier": "M90 24S", "winter_efficiency_pct": 79.1, "summer_efficiency_pct": 69.0, "comparative_hot_water_efficiency_pct": 48.5, "output_kw_max": 24.0, "final_year_of_manufacture": 2007, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008466", "000208", "0", "2008/May/22 11:40", "Biasi SpA", "Biasi", "Parva", "M90 24S", "47-970-13", "2001", "2007", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "24", "24", "", "", "79.1", "69.0", "", "48.5", "", "2", "", "", "104", "1", "2", "150", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.3", "78.4", "", "", "", "", "79.1"]} +{"pcdb_id": 8467, "brand_name": "Glow-worm", "model_name": "Saunier Duval SD30e", "model_qualifier": "A", "winter_efficiency_pct": 80.1, "summer_efficiency_pct": 70.0, "comparative_hot_water_efficiency_pct": 49.2, "output_kw_max": 28.2, "final_year_of_manufacture": 2003, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008467", "000206", "0", "2006/Jan/17 12:55", "Glow-worm", "Glow-worm", "Saunier Duval SD30e", "A", "GC 47 920 16", "1999", "2003", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "28.2", "28.2", "", "", "80.1", "70.0", "", "49.2", "", "2", "", "", "104", "1", "2", "150", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.4", "80.2", "", "", "", "", "80.6"]} +{"pcdb_id": 8468, "brand_name": "Glow-worm", "model_name": "Saunier Duval SB30e", "model_qualifier": "A", "winter_efficiency_pct": 80.3, "summer_efficiency_pct": 69.6, "comparative_hot_water_efficiency_pct": 50.8, "output_kw_max": 28.2, "final_year_of_manufacture": 2003, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008468", "000206", "0", "2012/Mar/27 10:12", "Glow-worm", "Glow-worm", "Saunier Duval SB30e", "A", "GC 41 920 31", "1999", "2003", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "28.2", "28.2", "", "", "80.3", "69.6", "", "50.8", "", "2", "", "", "102", "1", "2", "150", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.4", "80.2", "", "", "", "", "80.6"]} +{"pcdb_id": 8469, "brand_name": "Glow-worm", "model_name": "Compact 60 System", "model_qualifier": "A", "winter_efficiency_pct": 80.5, "summer_efficiency_pct": 69.8, "comparative_hot_water_efficiency_pct": 50.9, "output_kw_max": 17.58, "final_year_of_manufacture": 2003, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008469", "000207", "0", "2012/Mar/27 10:12", "Glow-worm", "Glow-worm", "Compact 60 System", "A", "GC 41-047-27", "1999", "2003", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "17.58", "17.58", "", "", "80.5", "69.8", "", "50.9", "", "2", "", "", "102", "1", "2", "150", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.5", "80.4", "", "", "", "", "80.8"]} +{"pcdb_id": 8470, "brand_name": "Glow-worm", "model_name": "Compact 80e", "model_qualifier": "A", "winter_efficiency_pct": 80.4, "summer_efficiency_pct": 70.3, "comparative_hot_water_efficiency_pct": 49.4, "output_kw_max": 23.45, "final_year_of_manufacture": 2003, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008470", "000207", "0", "2006/Jan/17 12:55", "Glow-worm", "Glow-worm", "Compact 80e", "A", "GC 47 047 07A", "1999", "2003", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "23.45", "23.45", "", "", "80.4", "70.3", "", "49.4", "", "2", "", "", "104", "1", "2", "150", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.6", "80.5", "", "", "", "", "80.9"]} +{"pcdb_id": 8471, "brand_name": "Glow-worm", "model_name": "Compact 100 System", "model_qualifier": "A", "winter_efficiency_pct": 80.3, "summer_efficiency_pct": 69.6, "comparative_hot_water_efficiency_pct": 50.8, "output_kw_max": 28.2, "final_year_of_manufacture": 2003, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008471", "000207", "0", "2012/Mar/27 10:12", "Glow-worm", "Glow-worm", "Compact 100 System", "A", "GC 41 047 26", "1999", "2003", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "28.2", "28.2", "", "", "80.3", "69.6", "", "50.8", "", "2", "", "", "102", "1", "2", "150", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.4", "80.2", "", "", "", "", "80.6"]} +{"pcdb_id": 8472, "brand_name": "Glow-worm", "model_name": "Compact 100e", "model_qualifier": "A", "winter_efficiency_pct": 80.1, "summer_efficiency_pct": 70.0, "comparative_hot_water_efficiency_pct": 49.2, "output_kw_max": 28.2, "final_year_of_manufacture": 2003, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008472", "000207", "0", "2006/Jan/17 12:55", "Glow-worm", "Glow-worm", "Compact 100e", "A", "GC 47 047 08A", "1999", "2003", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "28.2", "28.2", "", "", "80.1", "70.0", "", "49.2", "", "2", "", "", "104", "1", "2", "150", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.4", "80.2", "", "", "", "", "80.6"]} +{"pcdb_id": 8473, "brand_name": "Clyde", "model_name": "GO4E", "model_qualifier": "", "winter_efficiency_pct": 79.6, "summer_efficiency_pct": 69.5, "comparative_hot_water_efficiency_pct": 50.8, "output_kw_max": 33.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008473", "000012", "0", "2012/Mar/27 10:12", "Clyde Combustions", "Clyde", "GO4E", "", "", "", "current", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "33.5", "33.5", "", "", "79.6", "69.5", "", "50.8", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.3", "81.1", "", "", "", "", "81.1"]} +{"pcdb_id": 8474, "brand_name": "Clyde", "model_name": "GO5E", "model_qualifier": "", "winter_efficiency_pct": 79.7, "summer_efficiency_pct": 69.6, "comparative_hot_water_efficiency_pct": 50.8, "output_kw_max": 43.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008474", "000012", "0", "2012/Mar/27 10:12", "Clyde Combustions", "Clyde", "GO5E", "", "", "1996", "current", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "43.6", "43.6", "", "", "79.7", "69.6", "", "50.8", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.4", "81.2", "", "", "", "", "81.2"]} +{"pcdb_id": 8475, "brand_name": "Clyde", "model_name": "GO6E", "model_qualifier": "", "winter_efficiency_pct": 79.6, "summer_efficiency_pct": 69.5, "comparative_hot_water_efficiency_pct": 50.8, "output_kw_max": 55.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008475", "000012", "0", "2012/Mar/27 10:12", "Clyde Combustions", "Clyde", "GO6E", "", "", "", "current", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "55", "55", "", "", "79.6", "69.5", "", "50.8", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.3", "81.2", "", "", "", "", "81.2"]} +{"pcdb_id": 8476, "brand_name": "Clyde", "model_name": "GO7E", "model_qualifier": "", "winter_efficiency_pct": 79.6, "summer_efficiency_pct": 69.5, "comparative_hot_water_efficiency_pct": 50.8, "output_kw_max": 63.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008476", "000012", "0", "2012/Mar/27 10:12", "Clyde Combustions", "Clyde", "GO7E", "", "", "", "current", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "63.5", "63.5", "", "", "79.6", "69.5", "", "50.8", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.2", "81.2", "", "", "", "", "81.2"]} +{"pcdb_id": 8478, "brand_name": "Clyde", "model_name": "CW60", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 58.9, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008478", "000012", "0", "2012/Mar/27 10:12", "Clyde Combustions", "Clyde", "CW60", "", "", "", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "58.9", "58.9", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "84", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.4", "97.6", "", "", "", "", "95.8"]} +{"pcdb_id": 8479, "brand_name": "Clyde", "model_name": "CW45", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 43.7, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008479", "000012", "0", "2012/Mar/27 10:12", "Clyde Combustions", "Clyde", "CW45", "", "", "", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "43.7", "43.7", "", "", "88.1", "79.1", "", "57.8", "", "2", "", "", "102", "1", "2", "51", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.4", "97.2", "", "", "", "", "95.4"]} +{"pcdb_id": 8480, "brand_name": "Boulter", "model_name": "Camray 5", "model_qualifier": "95/130A System", "winter_efficiency_pct": 86.4, "summer_efficiency_pct": 74.7, "comparative_hot_water_efficiency_pct": 54.6, "output_kw_max": 38.1, "final_year_of_manufacture": 2005, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008480", "000041", "0", "2012/Mar/27 10:12", "Boulter Boilers", "Boulter", "Camray 5", "95/130A System", "", "2001", "2005", "4", "1", "1", "1", "0", "", "", "1", "3", "2", "27.8", "38.1", "", "", "86.4", "74.7", "", "54.6", "", "2", "", "", "201", "1", "1", "145", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.0", "86.8", "", "", "", "", "86.6"]} +{"pcdb_id": 8482, "brand_name": "Boulter", "model_name": "Camray 5", "model_qualifier": "95/130A Utility", "winter_efficiency_pct": 86.4, "summer_efficiency_pct": 74.7, "comparative_hot_water_efficiency_pct": 54.6, "output_kw_max": 38.1, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008482", "000041", "0", "2012/Mar/27 10:12", "Boulter Boilers", "Boulter", "Camray 5", "95/130A Utility", "", "2001", "current", "4", "1", "1", "1", "0", "", "", "1", "3", "2", "27.8", "38.1", "", "", "86.4", "74.7", "", "54.6", "", "2", "", "", "201", "1", "1", "145", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.0", "86.8", "", "", "", "", "86.6"]} +{"pcdb_id": 8484, "brand_name": "Boulter", "model_name": "Camray 5", "model_qualifier": "95/130A", "winter_efficiency_pct": 86.4, "summer_efficiency_pct": 74.7, "comparative_hot_water_efficiency_pct": 54.6, "output_kw_max": 38.1, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008484", "000041", "0", "2012/Mar/27 10:12", "Boulter Boilers", "Boulter", "Camray 5", "95/130A", "", "2001", "current", "4", "1", "1", "1", "0", "", "", "1", "3", "2", "27.8", "38.1", "", "", "86.4", "74.7", "", "54.6", "", "2", "", "", "201", "1", "1", "145", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.0", "86.8", "", "", "", "", "86.6"]} +{"pcdb_id": 8487, "brand_name": "Merlin", "model_name": "45/65 BL", "model_qualifier": "", "winter_efficiency_pct": 84.8, "summer_efficiency_pct": 73.1, "comparative_hot_water_efficiency_pct": 53.4, "output_kw_max": 19.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008487", "000210", "0", "2012/Mar/27 10:12", "BH Associates", "Merlin", "45/65 BL", "", "", "1994", "current", "4", "1", "1", "1", "0", "", "", "1", "2", "1", "13.2", "19", "", "", "84.8", "73.1", "", "53.4", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.5", "84.1", "", "", "", "", "84.4"]} +{"pcdb_id": 8488, "brand_name": "Merlin", "model_name": "45/65 CF", "model_qualifier": "", "winter_efficiency_pct": 84.8, "summer_efficiency_pct": 73.1, "comparative_hot_water_efficiency_pct": 53.4, "output_kw_max": 19.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008488", "000210", "0", "2012/Mar/27 10:12", "BH Associates", "Merlin", "45/65 CF", "", "", "1994", "current", "4", "1", "1", "1", "0", "", "", "1", "1", "1", "13.2", "19", "", "", "84.8", "73.1", "", "53.4", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.5", "84.1", "", "", "", "", "84.4"]} +{"pcdb_id": 8489, "brand_name": "Merlin", "model_name": "100/150 BF", "model_qualifier": "", "winter_efficiency_pct": 82.4, "summer_efficiency_pct": 70.7, "comparative_hot_water_efficiency_pct": 51.6, "output_kw_max": 44.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008489", "000210", "0", "2012/Mar/27 10:12", "BH Associates", "Merlin", "100/150 BF", "", "", "1994", "current", "4", "1", "1", "1", "0", "", "", "1", "2", "1", "29.3", "44", "", "", "82.4", "70.7", "", "51.6", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.5", "82.3", "", "", "", "", "82.3"]} +{"pcdb_id": 8490, "brand_name": "Merlin", "model_name": "100/150 CF", "model_qualifier": "", "winter_efficiency_pct": 82.4, "summer_efficiency_pct": 70.7, "comparative_hot_water_efficiency_pct": 51.6, "output_kw_max": 44.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008490", "000210", "0", "2012/Mar/27 10:12", "BH Associates", "Merlin", "100/150 CF", "", "", "1994", "current", "4", "1", "1", "1", "0", "", "", "1", "1", "1", "29.3", "44", "", "", "82.4", "70.7", "", "51.6", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.5", "82.3", "", "", "", "", "82.3"]} +{"pcdb_id": 8491, "brand_name": "Merlin", "model_name": "65/95 BL", "model_qualifier": "", "winter_efficiency_pct": 82.9, "summer_efficiency_pct": 71.2, "comparative_hot_water_efficiency_pct": 52.0, "output_kw_max": 27.8, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008491", "000210", "0", "2012/Mar/27 10:12", "BH Associates", "Merlin", "65/95 BL", "", "", "1994", "current", "4", "1", "1", "1", "0", "", "", "1", "2", "1", "19", "27.8", "", "", "82.9", "71.2", "", "52.0", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "83.3", "82.5", "", "", "", "", "82.7"]} +{"pcdb_id": 8492, "brand_name": "Merlin", "model_name": "65/95 CF", "model_qualifier": "", "winter_efficiency_pct": 82.9, "summer_efficiency_pct": 71.2, "comparative_hot_water_efficiency_pct": 52.0, "output_kw_max": 27.8, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008492", "000210", "0", "2012/Mar/27 10:12", "BH Associates", "Merlin", "65/95 CF", "", "", "1994", "current", "4", "1", "1", "1", "0", "", "", "1", "1", "1", "19", "27.8", "", "", "82.9", "71.2", "", "52.0", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "83.3", "82.5", "", "", "", "", "82.7"]} +{"pcdb_id": 8493, "brand_name": "Merlin", "model_name": "Internal Wall Hung", "model_qualifier": "40/65 BL", "winter_efficiency_pct": 81.9, "summer_efficiency_pct": 70.2, "comparative_hot_water_efficiency_pct": 51.3, "output_kw_max": 19.0, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008493", "000210", "0", "2012/Mar/27 10:12", "BH Associates", "Merlin", "Internal Wall Hung", "40/65 BL", "", "1995", "2001", "4", "2", "1", "1", "0", "", "", "1", "2", "1", "11.7", "19", "", "", "81.9", "70.2", "", "51.3", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.5", "81.3", "", "", "", "", "81.6"]} +{"pcdb_id": 8494, "brand_name": "Merlin", "model_name": "Internal Wall Hung", "model_qualifier": "40/65 CF", "winter_efficiency_pct": 81.9, "summer_efficiency_pct": 70.2, "comparative_hot_water_efficiency_pct": 51.3, "output_kw_max": 19.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008494", "000210", "0", "2012/Mar/27 10:12", "BH Associates", "Merlin", "Internal Wall Hung", "40/65 CF", "", "1995", "current", "4", "2", "1", "1", "0", "", "", "1", "1", "1", "11.7", "19", "", "", "81.9", "70.2", "", "51.3", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.5", "81.3", "", "", "", "", "81.6"]} +{"pcdb_id": 8495, "brand_name": "Merlin", "model_name": "Internal Wall Hung", "model_qualifier": "40/65 EXT", "winter_efficiency_pct": 81.9, "summer_efficiency_pct": 70.2, "comparative_hot_water_efficiency_pct": 51.3, "output_kw_max": 19.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008495", "000210", "0", "2012/Mar/27 10:12", "BH Associates", "Merlin", "Internal Wall Hung", "40/65 EXT", "", "1997", "current", "4", "2", "2", "1", "0", "", "", "1", "1", "1", "11.7", "19", "", "", "81.9", "70.2", "", "51.3", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.5", "81.3", "", "", "", "", "81.6"]} +{"pcdb_id": 8496, "brand_name": "Worcester", "model_name": "24 CDi", "model_qualifier": "RSF-L", "winter_efficiency_pct": 81.4, "summer_efficiency_pct": 71.3, "comparative_hot_water_efficiency_pct": 50.2, "output_kw_max": 24.0, "final_year_of_manufacture": 2005, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008496", "000035", "0", "2020/Sep/02 14:14", "Worcester Heat Systems", "Worcester", "24 CDi", "RSF-L", "47 311 31", "2001", "2005", "2", "2", "1", "2", "0", "", "", "1", "2", "2", "24", "24", "", "", "81.4", "71.3", "", "50.2", "", "2", "0", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "84.8", "80.5", "", "", "", "", "81.3"]} +{"pcdb_id": 8497, "brand_name": "Worcester", "model_name": "24 CDi", "model_qualifier": "RSF-L", "winter_efficiency_pct": 79.0, "summer_efficiency_pct": 68.9, "comparative_hot_water_efficiency_pct": 48.5, "output_kw_max": 24.0, "final_year_of_manufacture": 2005, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008497", "000035", "0", "2020/Sep/02 14:14", "Worcester Heat Systems", "Worcester", "24 CDi", "RSF-L", "47 311 30", "2001", "2005", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "24", "24", "", "", "79.0", "68.9", "", "48.5", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.4", "78.1", "", "", "", "", "78.9"]} +{"pcdb_id": 8499, "brand_name": "Boulter", "model_name": "Camray 5 Wall Hung", "model_qualifier": "50/70 External", "winter_efficiency_pct": 86.4, "summer_efficiency_pct": 74.7, "comparative_hot_water_efficiency_pct": 54.6, "output_kw_max": 20.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008499", "000041", "0", "2012/Mar/27 10:12", "Boulter Boilers", "Boulter", "Camray 5 Wall Hung", "50/70 External", "", "2001", "current", "4", "2", "2", "1", "0", "", "", "1", "2", "2", "14.5", "20.5", "", "", "86.4", "74.7", "", "54.6", "", "2", "", "", "201", "1", "1", "170", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.6", "87.7", "", "", "", "", "87.3"]} +{"pcdb_id": 8500, "brand_name": "Quantum", "model_name": "DB", "model_qualifier": "System Boiler", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 78.9, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 23.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008500", "000205", "0", "2012/Mar/27 10:12", "Quantum Heating", "Quantum", "DB", "System Boiler", "", "2001", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "23", "23", "", "", "87.9", "78.9", "", "57.7", "", "2", "", "", "102", "1", "2", "85", "85", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.7", "96.8", "", "", "", "", "95.0"]} +{"pcdb_id": 8501, "brand_name": "Quantum", "model_name": "DB", "model_qualifier": "", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 78.9, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 23.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008501", "000205", "0", "2012/Mar/27 10:12", "Quantum Heating", "Quantum", "DB", "", "", "2001", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "23", "23", "", "", "87.9", "78.9", "", "57.7", "", "2", "", "", "102", "1", "2", "85", "85", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.7", "96.8", "", "", "", "", "95.0"]} +{"pcdb_id": 8502, "brand_name": "Quantum", "model_name": "DB", "model_qualifier": "System Boiler", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 23.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008502", "000205", "0", "2012/Mar/27 10:12", "Quantum Heating", "Quantum", "DB", "System Boiler", "", "2001", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "23.5", "23.5", "", "", "88.9", "79.9", "", "58.3", "", "2", "0", "", "102", "1", "2", "85", "85", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.5", "96.2", "", "", "", "", "95.0"]} +{"pcdb_id": 8503, "brand_name": "Quantum", "model_name": "DB", "model_qualifier": "", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 23.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008503", "000205", "0", "2012/Mar/27 10:12", "Quantum Heating", "Quantum", "DB", "", "", "2001", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "23.5", "23.5", "", "", "88.9", "79.9", "", "58.3", "", "2", "0", "", "102", "1", "2", "85", "85", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.5", "96.2", "", "", "", "", "95.0"]} +{"pcdb_id": 8504, "brand_name": "Halstead", "model_name": "Best 70 db", "model_qualifier": "", "winter_efficiency_pct": 79.4, "summer_efficiency_pct": 69.3, "comparative_hot_water_efficiency_pct": 50.6, "output_kw_max": 20.5, "final_year_of_manufacture": 2006, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008504", "000019", "0", "2012/Mar/27 10:12", "Halstead Boilers", "Halstead", "Best 70 db", "", "DBX70", "2001", "2006", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "0", "20.5", "", "", "79.4", "69.3", "", "50.6", "", "2", "", "", "101", "1", "1", "45", "5", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "80.6", "81.4", "", "", "", "", "81.2"]} +{"pcdb_id": 8505, "brand_name": "Halstead", "model_name": "Best 60 db", "model_qualifier": "", "winter_efficiency_pct": 80.1, "summer_efficiency_pct": 70.0, "comparative_hot_water_efficiency_pct": 51.1, "output_kw_max": 19.4, "final_year_of_manufacture": 2006, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008505", "000019", "0", "2012/Mar/27 10:12", "Halstead Boilers", "Halstead", "Best 60 db", "", "DBX60", "2001", "2006", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "0", "19.4", "", "", "80.1", "70.0", "", "51.1", "", "2", "", "", "101", "1", "1", "45", "5", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.5", "81.8", "", "", "", "", "81.8"]} +{"pcdb_id": 8506, "brand_name": "Halstead", "model_name": "Best 50 db", "model_qualifier": "", "winter_efficiency_pct": 79.0, "summer_efficiency_pct": 68.9, "comparative_hot_water_efficiency_pct": 50.3, "output_kw_max": 14.6, "final_year_of_manufacture": 2006, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008506", "000019", "0", "2012/Mar/27 10:12", "Halstead Boilers", "Halstead", "Best 50 db", "", "DBX50", "2001", "2006", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "0", "14.6", "", "", "79.0", "68.9", "", "50.3", "", "2", "", "", "101", "1", "1", "45", "5", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "80.5", "80.6", "", "", "", "", "80.6"]} +{"pcdb_id": 8507, "brand_name": "Halstead", "model_name": "Best 40 db", "model_qualifier": "", "winter_efficiency_pct": 79.5, "summer_efficiency_pct": 69.4, "comparative_hot_water_efficiency_pct": 50.7, "output_kw_max": 11.7, "final_year_of_manufacture": 2006, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008507", "000019", "0", "2012/Mar/27 10:12", "Halstead Boilers", "Halstead", "Best 40 db", "", "DBX40", "2001", "2006", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "0", "11.7", "", "", "79.5", "69.4", "", "50.7", "", "2", "", "", "101", "1", "1", "45", "5", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.3", "81.0", "", "", "", "", "81.1"]} +{"pcdb_id": 8508, "brand_name": "Halstead", "model_name": "Best 30 db", "model_qualifier": "", "winter_efficiency_pct": 79.0, "summer_efficiency_pct": 68.9, "comparative_hot_water_efficiency_pct": 50.3, "output_kw_max": 8.8, "final_year_of_manufacture": 2006, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008508", "000019", "0", "2012/Mar/27 10:12", "Halstead Boilers", "Halstead", "Best 30 db", "", "DBX30", "2001", "2006", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "0", "8.8", "", "", "79.0", "68.9", "", "50.3", "", "2", "", "", "101", "1", "1", "45", "5", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "80.7", "80.5", "", "", "", "", "80.5"]} +{"pcdb_id": 8509, "brand_name": "Halstead", "model_name": "Wickes", "model_qualifier": "LW 40 ci", "winter_efficiency_pct": 79.5, "summer_efficiency_pct": 69.4, "comparative_hot_water_efficiency_pct": 50.7, "output_kw_max": 11.7, "final_year_of_manufacture": 2006, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008509", "000019", "0", "2012/Mar/27 10:12", "Halstead Boilers", "Halstead", "Wickes", "LW 40 ci", "DBXW40", "2001", "2006", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "0", "11.7", "", "", "79.5", "69.4", "", "50.7", "", "2", "", "", "101", "1", "1", "45", "5", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.3", "81.0", "", "", "", "", "81.1"]} +{"pcdb_id": 8510, "brand_name": "Halstead", "model_name": "Wickes", "model_qualifier": "LW 50 ci", "winter_efficiency_pct": 79.0, "summer_efficiency_pct": 68.9, "comparative_hot_water_efficiency_pct": 50.3, "output_kw_max": 14.6, "final_year_of_manufacture": 2006, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008510", "000019", "0", "2012/Mar/27 10:12", "Halstead Boilers", "Halstead", "Wickes", "LW 50 ci", "DBXW50", "2001", "2006", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "0", "14.6", "", "", "79.0", "68.9", "", "50.3", "", "2", "", "", "101", "1", "1", "45", "5", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "80.5", "80.6", "", "", "", "", "80.6"]} +{"pcdb_id": 8511, "brand_name": "Halstead", "model_name": "Wickes", "model_qualifier": "LW 60 ci", "winter_efficiency_pct": 80.1, "summer_efficiency_pct": 70.0, "comparative_hot_water_efficiency_pct": 51.1, "output_kw_max": 17.6, "final_year_of_manufacture": 2006, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008511", "000019", "0", "2012/Mar/27 10:12", "Halstead Boilers", "Halstead", "Wickes", "LW 60 ci", "DBX60", "2001", "2006", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "0", "17.6", "", "", "80.1", "70.0", "", "51.1", "", "2", "", "", "101", "1", "1", "45", "5", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.5", "81.8", "", "", "", "", "81.8"]} +{"pcdb_id": 8512, "brand_name": "Halstead", "model_name": "Finest", "model_qualifier": "fx", "winter_efficiency_pct": 80.2, "summer_efficiency_pct": 70.1, "comparative_hot_water_efficiency_pct": 49.3, "output_kw_max": 26.4, "final_year_of_manufacture": 2006, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008512", "000019", "0", "2008/Feb/19 10:12", "Halstead Boilers", "Halstead", "Finest", "fx", "", "2001", "2006", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "26.4", "26.4", "", "", "80.2", "70.1", "", "49.3", "", "2", "", "", "104", "1", "2", "150", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.5", "81.3", "", "", "", "", "81.3"]} +{"pcdb_id": 8513, "brand_name": "Halstead", "model_name": "Finest Gold", "model_qualifier": "fgx", "winter_efficiency_pct": 80.2, "summer_efficiency_pct": 70.1, "comparative_hot_water_efficiency_pct": 49.3, "output_kw_max": 30.0, "final_year_of_manufacture": 2006, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008513", "000019", "0", "2008/Feb/19 10:14", "Halstead Boilers", "Halstead", "Finest Gold", "fgx", "", "2001", "2006", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "30", "30", "", "", "80.2", "70.1", "", "49.3", "", "2", "", "", "104", "1", "2", "160", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.5", "81.3", "", "", "", "", "81.3"]} +{"pcdb_id": 8514, "brand_name": "Halstead", "model_name": "Ace", "model_qualifier": "acl", "winter_efficiency_pct": 79.0, "summer_efficiency_pct": 68.9, "comparative_hot_water_efficiency_pct": 48.5, "output_kw_max": 24.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008514", "000019", "0", "2008/Feb/19 11:43", "Halstead Boilers", "Halstead", "Ace", "acl", "", "2001", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "24", "24", "", "", "79.0", "68.9", "", "48.5", "", "2", "", "", "104", "1", "2", "160", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.3", "78.2", "", "", "", "", "79.0"]} +{"pcdb_id": 8515, "brand_name": "Halstead", "model_name": "Wickes", "model_qualifier": "Combi 82", "winter_efficiency_pct": 79.0, "summer_efficiency_pct": 68.9, "comparative_hot_water_efficiency_pct": 48.5, "output_kw_max": 24.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008515", "000019", "0", "2006/Jan/17 12:31", "Halstead Boilers", "Halstead", "Wickes", "Combi 82", "ACLW", "2001", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "24", "24", "", "", "79.0", "68.9", "", "48.5", "", "2", "", "", "104", "1", "2", "160", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.3", "78.2", "", "", "", "", "79.0"]} +{"pcdb_id": 8516, "brand_name": "Halstead", "model_name": "Wickes", "model_qualifier": "Combi 102", "winter_efficiency_pct": 79.5, "summer_efficiency_pct": 69.4, "comparative_hot_water_efficiency_pct": 48.8, "output_kw_max": 30.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008516", "000019", "0", "2006/Jan/17 12:31", "Halstead Boilers", "Halstead", "Wickes", "Combi 102", "ACHW", "2001", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "30", "30", "", "", "79.5", "69.4", "", "48.8", "", "2", "", "", "104", "1", "2", "160", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "83.2", "78.5", "", "", "", "", "79.4"]} +{"pcdb_id": 8517, "brand_name": "Halstead", "model_name": "Ace High", "model_qualifier": "", "winter_efficiency_pct": 79.5, "summer_efficiency_pct": 69.4, "comparative_hot_water_efficiency_pct": 48.8, "output_kw_max": 30.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008517", "000019", "0", "2006/Jan/17 12:31", "Halstead Boilers", "Halstead", "Ace High", "", "ACH", "2001", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "30", "30", "", "", "79.5", "69.4", "", "48.8", "", "2", "", "", "104", "1", "2", "160", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "83.2", "78.5", "", "", "", "", "79.4"]} +{"pcdb_id": 8522, "brand_name": "Geminox", "model_name": "THR 5-25C", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 25.6, "final_year_of_manufacture": 2006, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008522", "000212", "0", "2012/Mar/27 10:12", "Geminox SA", "Geminox", "THR 5-25C", "", "5-25C", "1997", "2006", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "25.6", "25.6", "", "", "88.3", "79.3", "", "58.0", "", "2", "", "", "102", "1", "2", "90", "15", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "97.8", "", "", "", "", "95.9"]} +{"pcdb_id": 8523, "brand_name": "Geminox", "model_name": "THR 5-25SEP", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 56.1, "output_kw_max": 25.6, "final_year_of_manufacture": 2006, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008523", "000212", "0", "2006/Aug/30 12:40", "Geminox SA", "Geminox", "THR 5-25SEP", "", "5-25SEP", "1998", "2006", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "25.6", "25.6", "", "", "88.3", "79.7", "", "56.1", "", "2", "", "", "104", "1", "2", "90", "15", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "97.8", "", "", "", "", "95.9"]} +{"pcdb_id": 8524, "brand_name": "Geminox", "model_name": "THR 5-25S", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 81.1, "comparative_hot_water_efficiency_pct": 52.4, "output_kw_max": 25.6, "final_year_of_manufacture": 2006, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008524", "000212", "0", "2024/Jan/31 10:17", "Geminox SA", "Geminox", "THR 5-25S", "", "5-25S", "1996", "2006", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "25.6", "25.6", "", "", "88.3", "81.1", "", "52.4", "", "2", "", "", "106", "1", "2", "90", "15", "2", "2", "0", "18.5", "0", "30", "2", "65", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "97.8", "", "", "", "", "95.9"]} +{"pcdb_id": 8525, "brand_name": "Geminox", "model_name": "THR 5-25 M75", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 81.2, "comparative_hot_water_efficiency_pct": 49.2, "output_kw_max": 25.6, "final_year_of_manufacture": 2006, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008525", "000212", "0", "2024/Jan/31 10:17", "Geminox SA", "Geminox", "THR 5-25 M75", "", "THR M75", "1997", "2006", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "25.6", "25.6", "", "", "88.3", "81.2", "", "49.2", "", "2", "", "", "106", "1", "2", "90", "15", "2", "2", "0", "74", "0", "30", "2", "65", "52", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "97.8", "", "", "", "", "95.9"]} +{"pcdb_id": 8527, "brand_name": "Geminox", "model_name": "THR 10-50", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 50.5, "final_year_of_manufacture": 2006, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008527", "000212", "0", "2012/Mar/27 10:12", "Geminox SA", "Geminox", "THR 10-50", "", "THR 50", "1997", "2006", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "50.5", "50.5", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "90", "30", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.7", "97.0", "", "", "", "", "95.3"]} +{"pcdb_id": 8529, "brand_name": "Worcester", "model_name": "9/14 CBi", "model_qualifier": "RSF", "winter_efficiency_pct": 79.4, "summer_efficiency_pct": 69.3, "comparative_hot_water_efficiency_pct": 50.6, "output_kw_max": 14.0, "final_year_of_manufacture": 2005, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008529", "000035", "0", "2020/Sep/02 14:14", "Worcester Heat Systems", "Worcester", "9/14 CBi", "RSF", "41-311-50", "2001", "2005", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "9", "14", "", "", "79.4", "69.3", "", "50.6", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.5", "79.5", "", "", "", "", "80.1"]} +{"pcdb_id": 8530, "brand_name": "Worcester", "model_name": "9/14 CBi", "model_qualifier": "RSF", "winter_efficiency_pct": 81.4, "summer_efficiency_pct": 71.3, "comparative_hot_water_efficiency_pct": 52.1, "output_kw_max": 14.0, "final_year_of_manufacture": 2005, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008530", "000035", "0", "2020/Sep/02 14:15", "Worcester Heat Systems", "Worcester", "9/14 CBi", "RSF", "41-311-51", "2001", "2005", "2", "2", "1", "1", "0", "", "", "1", "2", "2", "10", "14", "", "", "81.4", "71.3", "", "52.1", "", "2", "0", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "84.5", "81.6", "", "", "", "", "82.1"]} +{"pcdb_id": 8531, "brand_name": "Worcester", "model_name": "14/19 CBi", "model_qualifier": "RSF", "winter_efficiency_pct": 80.3, "summer_efficiency_pct": 70.2, "comparative_hot_water_efficiency_pct": 51.2, "output_kw_max": 19.05, "final_year_of_manufacture": 2005, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008531", "000035", "0", "2020/Sep/02 14:15", "Worcester Heat Systems", "Worcester", "14/19 CBi", "RSF", "41-311-52", "2001", "2005", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "14", "19.05", "", "", "80.3", "70.2", "", "51.2", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "83.5", "80.8", "", "", "", "", "81.3"]} +{"pcdb_id": 8532, "brand_name": "Worcester", "model_name": "14/19 CBi", "model_qualifier": "RSF", "winter_efficiency_pct": 82.2, "summer_efficiency_pct": 72.1, "comparative_hot_water_efficiency_pct": 52.6, "output_kw_max": 19.05, "final_year_of_manufacture": 2005, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008532", "000035", "0", "2020/Sep/02 14:15", "Worcester Heat Systems", "Worcester", "14/19 CBi", "RSF", "41-311-53", "2001", "2005", "2", "2", "1", "1", "0", "", "", "1", "2", "2", "14", "19.05", "", "", "82.2", "72.1", "", "52.6", "", "2", "0", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.7", "82.8", "", "", "", "", "83.4"]} +{"pcdb_id": 8533, "brand_name": "Worcester", "model_name": "19/24 CBi", "model_qualifier": "RSF", "winter_efficiency_pct": 79.3, "summer_efficiency_pct": 69.2, "comparative_hot_water_efficiency_pct": 50.6, "output_kw_max": 23.45, "final_year_of_manufacture": 2005, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008533", "000035", "0", "2020/Sep/02 14:15", "Worcester Heat Systems", "Worcester", "19/24 CBi", "RSF", "41-311-54", "2001", "2005", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "19.05", "23.45", "", "", "79.3", "69.2", "", "50.6", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.1", "79.7", "", "", "", "", "80.2"]} +{"pcdb_id": 8534, "brand_name": "Worcester", "model_name": "19/24 CBi", "model_qualifier": "RSF", "winter_efficiency_pct": 81.3, "summer_efficiency_pct": 71.2, "comparative_hot_water_efficiency_pct": 52.0, "output_kw_max": 23.45, "final_year_of_manufacture": 2005, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008534", "000035", "0", "2020/Sep/02 14:15", "Worcester Heat Systems", "Worcester", "19/24 CBi", "RSF", "41-311-55", "2001", "2005", "2", "2", "1", "1", "0", "", "", "1", "2", "2", "19.05", "23.45", "", "", "81.3", "71.2", "", "52.0", "", "2", "0", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "84.4", "81.4", "", "", "", "", "82.0"]} +{"pcdb_id": 8535, "brand_name": "Vaillant", "model_name": "Ecomax", "model_qualifier": "835/2E", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 56.2, "output_kw_max": 27.0, "final_year_of_manufacture": 2010, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008535", "000031", "0", "2010/Jan/28 08:35", "Vaillant", "Vaillant", "Ecomax", "835/2E", "VUW 356-C", "2001", "2010", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "27", "27", "", "", "88.5", "79.9", "", "56.2", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.0", "97.2", "", "", "", "", "95.8"]} +{"pcdb_id": 8537, "brand_name": "Radiant", "model_name": "RBA/CS 100 E", "model_qualifier": "", "winter_efficiency_pct": 79.4, "summer_efficiency_pct": 70.3, "comparative_hot_water_efficiency_pct": 26.3, "output_kw_max": 29.8, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 1, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008537", "000088", "0", "2024/Jan/31 10:17", "Radiant Bruciatori SpA", "Radiant", "RBA/CS 100 E", "", "CE 0063AQ6415", "1997", "current", "1", "1", "1", "2", "0", "", "", "1", "2", "2", "29.8", "29.8", "", "", "79.4", "70.3", "", "26.3", "", "2", "", "", "106", "1", "2", "170", "", "1", "2", "0", "107.1", "0", "15", "2", "60", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "80.5", "78.8", "", "", "", "", "79.2"]} +{"pcdb_id": 8538, "brand_name": "Radiant", "model_name": "RBA/CS 24 E", "model_qualifier": "", "winter_efficiency_pct": 79.1, "summer_efficiency_pct": 70.0, "comparative_hot_water_efficiency_pct": 31.8, "output_kw_max": 29.8, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008538", "000088", "0", "2024/Jan/31 10:17", "Radiant Bruciatori SpA", "Radiant", "RBA/CS 24 E", "", "CE 0063AQ6415", "1997", "current", "1", "1", "1", "2", "0", "", "", "1", "2", "2", "29.8", "29.8", "", "", "79.1", "70.0", "", "31.8", "", "2", "", "", "106", "1", "2", "170", "", "2", "2", "0", "50.7", "0", "15", "2", "60", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "80.5", "78.8", "", "", "", "", "79.2"]} +{"pcdb_id": 8539, "brand_name": "Radiant", "model_name": "RBC 20 E", "model_qualifier": "", "winter_efficiency_pct": 77.6, "summer_efficiency_pct": 67.5, "comparative_hot_water_efficiency_pct": 47.5, "output_kw_max": 26.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008539", "000088", "0", "2006/Jan/17 12:31", "Radiant Bruciatori SpA", "Radiant", "RBC 20 E", "", "CE 0694BL3037", "2000", "current", "1", "2", "1", "2", "0", "", "", "1", "1", "1", "26.6", "26.6", "", "", "77.6", "67.5", "", "47.5", "", "2", "", "", "104", "1", "2", "170", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "80.3", "77.4", "", "", "", "", "77.9"]} +{"pcdb_id": 8540, "brand_name": "Radiant", "model_name": "RBS 20 E", "model_qualifier": "", "winter_efficiency_pct": 78.4, "summer_efficiency_pct": 68.3, "comparative_hot_water_efficiency_pct": 48.0, "output_kw_max": 26.6, "final_year_of_manufacture": 2002, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008540", "000088", "0", "2006/Jan/17 12:55", "Radiant Bruciatori SpA", "Radiant", "RBS 20 E", "", "CE 0694BL3037", "2000", "2002", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "26.6", "26.6", "", "", "78.4", "68.3", "", "48.0", "", "2", "", "", "104", "1", "2", "170", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.4", "77.8", "", "", "", "", "78.4"]} +{"pcdb_id": 8541, "brand_name": "Radiant", "model_name": "RMAS 21 E/3S", "model_qualifier": "", "winter_efficiency_pct": 82.2, "summer_efficiency_pct": 73.1, "comparative_hot_water_efficiency_pct": 36.2, "output_kw_max": 26.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008541", "000088", "0", "2024/Jan/31 10:17", "Radiant Bruciatori SpA", "Radiant", "RMAS 21 E/3S", "", "0694BL3003", "2000", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "26.6", "26.6", "", "", "82.2", "73.1", "", "36.2", "", "2", "", "", "106", "1", "2", "170", "", "2", "2", "0", "28.3", "0", "15", "2", "60", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "83.8", "83.0", "", "", "", "", "83.1"]} +{"pcdb_id": 8542, "brand_name": "Radiant", "model_name": "RMAS 21 E NOx", "model_qualifier": "", "winter_efficiency_pct": 81.1, "summer_efficiency_pct": 72.0, "comparative_hot_water_efficiency_pct": 35.6, "output_kw_max": 26.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008542", "000088", "0", "2024/Jan/31 10:17", "Radiant Bruciatori SpA", "Radiant", "RMAS 21 E NOx", "", "CE 0694BL3003", "1998", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "26.6", "26.6", "", "", "81.1", "72.0", "", "35.6", "", "2", "", "", "106", "1", "2", "170", "", "2", "2", "0", "28.3", "0", "15", "2", "60", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.7", "80.9", "", "", "", "", "81.3"]} +{"pcdb_id": 8543, "brand_name": "Radiant", "model_name": "RMAS 24 E", "model_qualifier": "", "winter_efficiency_pct": 78.9, "summer_efficiency_pct": 69.8, "comparative_hot_water_efficiency_pct": 34.6, "output_kw_max": 29.8, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008543", "000088", "0", "2024/Jan/31 10:17", "Radiant Bruciatori SpA", "Radiant", "RMAS 24 E", "", "CE 0063AQ6415", "1997", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "29.8", "29.8", "", "", "78.9", "69.8", "", "34.6", "", "2", "", "", "106", "1", "2", "170", "", "2", "2", "0", "28.3", "0", "15", "2", "60", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "80.5", "78.8", "", "", "", "", "79.2"]} +{"pcdb_id": 8544, "brand_name": "Radiant", "model_name": "RS 20 E", "model_qualifier": "", "winter_efficiency_pct": 79.5, "summer_efficiency_pct": 68.8, "comparative_hot_water_efficiency_pct": 50.2, "output_kw_max": 26.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008544", "000088", "0", "2012/Mar/27 10:12", "Radiant Bruciatori SpA", "Radiant", "RS 20 E", "", "CE 0063AQ4089", "1997", "current", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "26.6", "26.6", "", "", "79.5", "68.8", "", "50.2", "", "2", "", "", "102", "1", "2", "170", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.4", "78.5", "", "", "", "", "79.2"]} +{"pcdb_id": 8545, "brand_name": "Radiant", "model_name": "RS 21 E/3S", "model_qualifier": "", "winter_efficiency_pct": 81.9, "summer_efficiency_pct": 71.2, "comparative_hot_water_efficiency_pct": 52.0, "output_kw_max": 26.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008545", "000088", "0", "2012/Mar/27 10:12", "Radiant Bruciatori SpA", "Radiant", "RS 21 E/3S", "", "CE 0694BL3003", "2000", "current", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "26.6", "26.6", "", "", "81.9", "71.2", "", "52.0", "", "2", "", "", "102", "1", "2", "170", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "83.8", "83.0", "", "", "", "", "83.1"]} +{"pcdb_id": 8546, "brand_name": "Radiant", "model_name": "RS 21 E NOx", "model_qualifier": "", "winter_efficiency_pct": 80.8, "summer_efficiency_pct": 70.1, "comparative_hot_water_efficiency_pct": 51.2, "output_kw_max": 26.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008546", "000088", "0", "2012/Mar/27 10:12", "Radiant Bruciatori SpA", "Radiant", "RS 21 E NOx", "", "CE 0694BL3003", "1998", "current", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "26.6", "26.6", "", "", "80.8", "70.1", "", "51.2", "", "2", "", "", "102", "1", "2", "170", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.7", "80.9", "", "", "", "", "81.3"]} +{"pcdb_id": 8547, "brand_name": "Radiant", "model_name": "RS 24 E", "model_qualifier": "", "winter_efficiency_pct": 78.7, "summer_efficiency_pct": 68.0, "comparative_hot_water_efficiency_pct": 49.7, "output_kw_max": 29.8, "final_year_of_manufacture": 2002, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008547", "000088", "0", "2012/Mar/27 10:12", "Radiant Bruciatori SpA", "Radiant", "RS 24 E", "", "CE 0063AQ6415", "1997", "2002", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "29.8", "29.8", "", "", "78.7", "68.0", "", "49.7", "", "2", "", "", "102", "1", "2", "170", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "80.5", "78.8", "", "", "", "", "79.2"]} +{"pcdb_id": 8548, "brand_name": "Radiant", "model_name": "RSF 20 E", "model_qualifier": "", "winter_efficiency_pct": 79.3, "summer_efficiency_pct": 69.2, "comparative_hot_water_efficiency_pct": 48.6, "output_kw_max": 26.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008548", "000088", "0", "2006/Jan/17 12:31", "Radiant Bruciatori SpA", "Radiant", "RSF 20 E", "", "CE 0063AQ4089", "1997", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "26.6", "26.6", "", "", "79.3", "69.2", "", "48.6", "", "2", "", "", "104", "1", "2", "170", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.4", "78.5", "", "", "", "", "79.2"]} +{"pcdb_id": 8549, "brand_name": "Radiant", "model_name": "RSF 21 E/3S", "model_qualifier": "", "winter_efficiency_pct": 81.7, "summer_efficiency_pct": 71.6, "comparative_hot_water_efficiency_pct": 50.4, "output_kw_max": 26.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008549", "000088", "0", "2006/Jan/17 12:31", "Radiant Bruciatori SpA", "Radiant", "RSF 21 E/3S", "", "CE 0694BL3003", "2000", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "26.6", "26.6", "", "", "81.7", "71.6", "", "50.4", "", "2", "", "", "104", "1", "2", "170", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "83.8", "83.0", "", "", "", "", "83.1"]} +{"pcdb_id": 8550, "brand_name": "Radiant", "model_name": "RSF 21 E NOx", "model_qualifier": "", "winter_efficiency_pct": 80.6, "summer_efficiency_pct": 70.5, "comparative_hot_water_efficiency_pct": 49.6, "output_kw_max": 26.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008550", "000088", "0", "2006/Jan/17 12:31", "Radiant Bruciatori SpA", "Radiant", "RSF 21 E NOx", "", "CE 0694BL3003", "1998", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "26.6", "26.6", "", "", "80.6", "70.5", "", "49.6", "", "2", "", "", "104", "1", "2", "170", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.7", "80.9", "", "", "", "", "81.3"]} +{"pcdb_id": 8551, "brand_name": "Radiant", "model_name": "RSF 24 E", "model_qualifier": "", "winter_efficiency_pct": 78.5, "summer_efficiency_pct": 68.4, "comparative_hot_water_efficiency_pct": 48.1, "output_kw_max": 29.8, "final_year_of_manufacture": 2002, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008551", "000088", "0", "2006/Jan/17 12:55", "Radiant Bruciatori SpA", "Radiant", "RSF 24 E", "", "CE 0063AQ6415", "1997", "2002", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "29.8", "29.8", "", "", "78.5", "68.4", "", "48.1", "", "2", "", "", "104", "1", "2", "170", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "80.5", "78.8", "", "", "", "", "79.2"]} +{"pcdb_id": 8552, "brand_name": "Gledhill", "model_name": "Gulfstream 2000", "model_qualifier": "GS2000/120/E-OV", "winter_efficiency_pct": 84.5, "summer_efficiency_pct": 85.3, "comparative_hot_water_efficiency_pct": 71.9, "output_kw_max": 19.8, "final_year_of_manufacture": 2005, "subsidiary_type": 0, "store_type": 3, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008552", "000072", "0", "2006/Mar/29 14:30", "Gledhill", "Gledhill", "Gulfstream 2000", "GS2000/120/E-OV", "12 OV", "2001", "2005", "1", "1", "1", "3", "0", "", "", "2", "2", "2", "19.8", "19.8", "", "", "84.5", "85.3", "", "71.9", "", "2", "", "", "107", "1", "2", "", "", "3", "2", "0", "80", "0", "60", "2", "80", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "84.5", "90.7", "", "", "", "", "89.5"]} +{"pcdb_id": 8553, "brand_name": "Gledhill", "model_name": "Gulfstream 2000", "model_qualifier": "GS2000/120/E", "winter_efficiency_pct": 84.5, "summer_efficiency_pct": 85.3, "comparative_hot_water_efficiency_pct": 71.9, "output_kw_max": 19.8, "final_year_of_manufacture": 2005, "subsidiary_type": 0, "store_type": 3, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008553", "000072", "0", "2007/Apr/24 10:44", "Gledhill", "Gledhill", "Gulfstream 2000", "GS2000/120/E", "12 SP", "2001", "2005", "1", "1", "1", "3", "0", "", "", "2", "2", "2", "19.8", "19.8", "", "", "84.5", "85.3", "", "71.9", "", "2", "", "", "107", "1", "2", "", "", "3", "2", "0", "80", "0", "60", "2", "80", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "84.5", "90.7", "", "", "", "", "89.5"]} +{"pcdb_id": 8554, "brand_name": "Gledhill", "model_name": "Gulfstream 2000", "model_qualifier": "GS2000/130/E-OV", "winter_efficiency_pct": 85.0, "summer_efficiency_pct": 85.8, "comparative_hot_water_efficiency_pct": 72.3, "output_kw_max": 29.3, "final_year_of_manufacture": 2005, "subsidiary_type": 0, "store_type": 3, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008554", "000072", "0", "2006/Mar/29 14:29", "Gledhill", "Gledhill", "Gulfstream 2000", "GS2000/130/E-OV", "18 OV", "2001", "2005", "1", "1", "1", "3", "0", "", "", "2", "2", "2", "29.3", "29.3", "", "", "85.0", "85.8", "", "72.3", "", "2", "", "", "107", "1", "2", "", "", "3", "2", "0", "80", "0", "60", "2", "80", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "85.3", "91.0", "", "", "", "", "89.9"]} +{"pcdb_id": 8555, "brand_name": "Gledhill", "model_name": "Gulfstream 2000", "model_qualifier": "GS2000/130/E", "winter_efficiency_pct": 85.0, "summer_efficiency_pct": 85.8, "comparative_hot_water_efficiency_pct": 72.3, "output_kw_max": 29.3, "final_year_of_manufacture": 2005, "subsidiary_type": 0, "store_type": 3, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008555", "000072", "0", "2006/Mar/29 14:30", "Gledhill", "Gledhill", "Gulfstream 2000", "GS2000/130/E", "18 SP", "2001", "2005", "1", "1", "1", "3", "0", "", "", "2", "2", "2", "29.3", "29.3", "", "", "85.0", "85.8", "", "72.3", "", "2", "", "", "107", "1", "2", "", "", "3", "2", "0", "80", "0", "60", "2", "80", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "85.3", "91.0", "", "", "", "", "89.9"]} +{"pcdb_id": 8556, "brand_name": "Baxi Potterton", "model_name": "Baxi Bermuda Inset 2", "model_qualifier": "50/4E", "winter_efficiency_pct": 78.4, "summer_efficiency_pct": 68.3, "comparative_hot_water_efficiency_pct": 49.9, "output_kw_max": 14.65, "final_year_of_manufacture": 2003, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008556", "000005", "0", "2012/Mar/27 10:12", "Baxi Potterton", "Baxi Potterton", "Baxi Bermuda Inset 2", "50/4E", "44-075-03", "2000", "2003", "1", "4", "1", "1", "0", "", "", "1", "1", "1", "11.72", "14.65", "", "", "78.4", "68.3", "", "49.9", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.6", "78.4", "", "", "", "", "79.0"]} +{"pcdb_id": 8557, "brand_name": "Potterton", "model_name": "Profile", "model_qualifier": "80eL", "winter_efficiency_pct": 79.3, "summer_efficiency_pct": 69.2, "comparative_hot_water_efficiency_pct": 50.5, "output_kw_max": 23.45, "final_year_of_manufacture": 2006, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008557", "000005", "0", "2012/Mar/27 10:12", "Baxi Potterton", "Potterton", "Profile", "80eL", "41-590-53", "2001", "2006", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "23.45", "23.45", "", "", "79.3", "69.2", "", "50.5", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.5", "80.3", "", "", "", "", "80.5"]} +{"pcdb_id": 8558, "brand_name": "Potterton", "model_name": "Profile", "model_qualifier": "60eL", "winter_efficiency_pct": 79.1, "summer_efficiency_pct": 69.0, "comparative_hot_water_efficiency_pct": 50.4, "output_kw_max": 17.58, "final_year_of_manufacture": 2005, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008558", "000005", "0", "2012/Mar/27 10:12", "Baxi Potterton", "Potterton", "Profile", "60eL", "41-590-52", "2001", "2005", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "17.58", "17.58", "", "", "79.1", "69.0", "", "50.4", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.0", "80.5", "", "", "", "", "80.6"]} +{"pcdb_id": 8559, "brand_name": "Potterton", "model_name": "Profile", "model_qualifier": "50eL", "winter_efficiency_pct": 79.2, "summer_efficiency_pct": 69.1, "comparative_hot_water_efficiency_pct": 50.5, "output_kw_max": 14.65, "final_year_of_manufacture": 2006, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008559", "000005", "0", "2012/Mar/27 10:12", "Baxi Potterton", "Potterton", "Profile", "50eL", "41-590-51", "2001", "2006", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "14.65", "14.65", "", "", "79.2", "69.1", "", "50.5", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.1", "80.5", "", "", "", "", "80.6"]} +{"pcdb_id": 8560, "brand_name": "Potterton", "model_name": "Profile", "model_qualifier": "40eL", "winter_efficiency_pct": 78.9, "summer_efficiency_pct": 68.8, "comparative_hot_water_efficiency_pct": 50.3, "output_kw_max": 11.72, "final_year_of_manufacture": 2006, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008560", "000005", "0", "2012/Mar/27 10:12", "Baxi Potterton", "Potterton", "Profile", "40eL", "41-590-50", "2001", "2006", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "11.72", "11.72", "", "", "78.9", "68.8", "", "50.3", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.2", "79.9", "", "", "", "", "80.2"]} +{"pcdb_id": 8561, "brand_name": "Potterton", "model_name": "Kingfisher MF", "model_qualifier": "RSL100", "winter_efficiency_pct": 78.9, "summer_efficiency_pct": 68.8, "comparative_hot_water_efficiency_pct": 50.3, "output_kw_max": 29.31, "final_year_of_manufacture": 2006, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008561", "000005", "0", "2012/Mar/27 10:12", "Baxi Potterton", "Potterton", "Kingfisher MF", "RSL100", "41-590-41", "2001", "2006", "1", "1", "1", "1", "0", "", "", "1", "2", "2", "29.31", "29.31", "", "", "78.9", "68.8", "", "50.3", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.0", "80.0", "", "", "", "", "80.2"]} +{"pcdb_id": 8562, "brand_name": "Potterton", "model_name": "Kingfisher MF", "model_qualifier": "RSL90", "winter_efficiency_pct": 79.0, "summer_efficiency_pct": 68.9, "comparative_hot_water_efficiency_pct": 50.3, "output_kw_max": 26.38, "final_year_of_manufacture": 2005, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008562", "000005", "0", "2012/Mar/27 10:12", "Baxi Potterton", "Potterton", "Kingfisher MF", "RSL90", "41-590-40", "2001", "2005", "1", "1", "1", "1", "0", "", "", "1", "2", "2", "26.38", "26.38", "", "", "79.0", "68.9", "", "50.3", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.1", "80.1", "", "", "", "", "80.3"]} +{"pcdb_id": 8563, "brand_name": "Potterton", "model_name": "Kingfisher MF", "model_qualifier": "RSL80", "winter_efficiency_pct": 79.1, "summer_efficiency_pct": 69.0, "comparative_hot_water_efficiency_pct": 50.4, "output_kw_max": 23.45, "final_year_of_manufacture": 2007, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008563", "000005", "0", "2012/Mar/27 10:12", "Baxi Potterton", "Potterton", "Kingfisher MF", "RSL80", "41-590-39", "2001", "2007", "1", "1", "1", "1", "0", "", "", "1", "2", "2", "23.45", "23.45", "", "", "79.1", "69.0", "", "50.4", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.2", "80.2", "", "", "", "", "80.4"]} +{"pcdb_id": 8564, "brand_name": "Potterton", "model_name": "Kingfisher MF", "model_qualifier": "RSL70", "winter_efficiency_pct": 79.0, "summer_efficiency_pct": 68.9, "comparative_hot_water_efficiency_pct": 50.4, "output_kw_max": 20.52, "final_year_of_manufacture": 2006, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008564", "000005", "0", "2012/Mar/27 10:12", "Baxi Potterton", "Potterton", "Kingfisher MF", "RSL70", "41-590-38", "2001", "2006", "1", "1", "1", "1", "0", "", "", "1", "2", "2", "20.52", "20.52", "", "", "79.0", "68.9", "", "50.4", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.1", "80.2", "", "", "", "", "80.4"]} +{"pcdb_id": 8565, "brand_name": "Potterton", "model_name": "Kingfisher MF", "model_qualifier": "RSL60", "winter_efficiency_pct": 79.4, "summer_efficiency_pct": 69.3, "comparative_hot_water_efficiency_pct": 50.6, "output_kw_max": 17.58, "final_year_of_manufacture": 2006, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008565", "000005", "0", "2012/Mar/27 10:12", "Baxi Potterton", "Potterton", "Kingfisher MF", "RSL60", "41-590-37", "2001", "2006", "1", "1", "1", "1", "0", "", "", "1", "2", "2", "17.58", "17.58", "", "", "79.4", "69.3", "", "50.6", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.5", "80.5", "", "", "", "", "80.7"]} +{"pcdb_id": 8566, "brand_name": "Potterton", "model_name": "Kingfisher MF", "model_qualifier": "RSL50", "winter_efficiency_pct": 79.4, "summer_efficiency_pct": 69.3, "comparative_hot_water_efficiency_pct": 50.6, "output_kw_max": 14.65, "final_year_of_manufacture": 2007, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008566", "000005", "0", "2012/Mar/27 10:12", "Baxi Potterton", "Potterton", "Kingfisher MF", "RSL50", "", "2001", "2007", "1", "1", "1", "1", "0", "", "", "1", "2", "2", "14.65", "14.65", "", "", "79.4", "69.3", "", "50.6", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.5", "80.4", "", "", "", "", "80.6"]} +{"pcdb_id": 8567, "brand_name": "Potterton", "model_name": "Kingfisher MF", "model_qualifier": "CFL100", "winter_efficiency_pct": 78.9, "summer_efficiency_pct": 68.8, "comparative_hot_water_efficiency_pct": 50.2, "output_kw_max": 29.31, "final_year_of_manufacture": 2005, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008567", "000005", "0", "2012/Mar/27 10:12", "Baxi Potterton", "Potterton", "Kingfisher MF", "CFL100", "41-590-34", "2001", "2005", "1", "1", "1", "1", "0", "", "", "1", "1", "2", "29.31", "29.31", "", "", "78.9", "68.8", "", "50.2", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.2", "79.7", "", "", "", "", "80.0"]} +{"pcdb_id": 8568, "brand_name": "Potterton", "model_name": "Kingfisher MF", "model_qualifier": "CFL90", "winter_efficiency_pct": 78.9, "summer_efficiency_pct": 68.8, "comparative_hot_water_efficiency_pct": 50.2, "output_kw_max": 26.38, "final_year_of_manufacture": 2005, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008568", "000005", "0", "2012/Mar/27 10:12", "Baxi Potterton", "Potterton", "Kingfisher MF", "CFL90", "41-590-32", "2001", "2005", "1", "1", "1", "1", "0", "", "", "1", "1", "2", "26.38", "26.38", "", "", "78.9", "68.8", "", "50.2", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.1", "79.8", "", "", "", "", "80.1"]} +{"pcdb_id": 8569, "brand_name": "Potterton", "model_name": "Kingfisher MF", "model_qualifier": "CFL80", "winter_efficiency_pct": 79.2, "summer_efficiency_pct": 69.1, "comparative_hot_water_efficiency_pct": 50.5, "output_kw_max": 23.45, "final_year_of_manufacture": 2007, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008569", "000005", "0", "2012/Mar/27 10:12", "Baxi Potterton", "Potterton", "Kingfisher MF", "CFL80", "41-590-31", "2001", "2007", "1", "1", "1", "1", "0", "", "", "1", "1", "2", "23.45", "23.45", "", "", "79.2", "69.1", "", "50.5", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.3", "80.3", "", "", "", "", "80.5"]} +{"pcdb_id": 8570, "brand_name": "Potterton", "model_name": "Kingfisher MF", "model_qualifier": "CFL70", "winter_efficiency_pct": 78.9, "summer_efficiency_pct": 68.8, "comparative_hot_water_efficiency_pct": 50.3, "output_kw_max": 20.52, "final_year_of_manufacture": 2006, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008570", "000005", "0", "2012/Mar/27 10:12", "Baxi Potterton", "Potterton", "Kingfisher MF", "CFL70", "41-590-30", "2001", "2006", "1", "1", "1", "1", "0", "", "", "1", "1", "2", "20.52", "20.52", "", "", "78.9", "68.8", "", "50.3", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.1", "79.9", "", "", "", "", "80.1"]} +{"pcdb_id": 8571, "brand_name": "Potterton", "model_name": "Kingfisher MF", "model_qualifier": "CFL60", "winter_efficiency_pct": 78.9, "summer_efficiency_pct": 68.8, "comparative_hot_water_efficiency_pct": 50.3, "output_kw_max": 17.58, "final_year_of_manufacture": 2006, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008571", "000005", "0", "2012/Mar/27 10:12", "Baxi Potterton", "Potterton", "Kingfisher MF", "CFL60", "41-590-29", "2001", "2006", "1", "1", "1", "1", "0", "", "", "1", "1", "2", "17.58", "17.58", "", "", "78.9", "68.8", "", "50.3", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.0", "80.0", "", "", "", "", "80.2"]} +{"pcdb_id": 8572, "brand_name": "Potterton", "model_name": "Kingfisher MF", "model_qualifier": "CFL50", "winter_efficiency_pct": 79.4, "summer_efficiency_pct": 69.3, "comparative_hot_water_efficiency_pct": 50.6, "output_kw_max": 14.65, "final_year_of_manufacture": 2007, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008572", "000005", "0", "2012/Mar/27 10:12", "Baxi Potterton", "Potterton", "Kingfisher MF", "CFL50", "41-590-28", "2001", "2007", "1", "1", "1", "1", "0", "", "", "1", "1", "2", "14.65", "14.65", "", "", "79.4", "69.3", "", "50.6", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.6", "80.3", "", "", "", "", "80.5"]} +{"pcdb_id": 8573, "brand_name": "Potterton", "model_name": "Suprima", "model_qualifier": "30L", "winter_efficiency_pct": 78.9, "summer_efficiency_pct": 68.8, "comparative_hot_water_efficiency_pct": 50.3, "output_kw_max": 8.8, "final_year_of_manufacture": 2005, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008573", "000005", "0", "2012/Mar/27 10:12", "Baxi Potterton", "Potterton", "Suprima", "30L", "41-590-42", "2001", "2005", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "8.8", "8.8", "", "", "78.9", "68.8", "", "50.3", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.3", "79.7", "", "", "", "", "80.0"]} +{"pcdb_id": 8574, "brand_name": "Potterton", "model_name": "Suprima", "model_qualifier": "40L", "winter_efficiency_pct": 79.4, "summer_efficiency_pct": 69.3, "comparative_hot_water_efficiency_pct": 50.6, "output_kw_max": 11.7, "final_year_of_manufacture": 2006, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008574", "000005", "0", "2012/Mar/27 10:12", "Baxi Potterton", "Potterton", "Suprima", "40L", "41-590-43", "2001", "2006", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "11.7", "11.7", "", "", "79.4", "69.3", "", "50.6", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.6", "80.4", "", "", "", "", "80.6"]} +{"pcdb_id": 8575, "brand_name": "Potterton", "model_name": "Suprima", "model_qualifier": "50L", "winter_efficiency_pct": 79.0, "summer_efficiency_pct": 68.9, "comparative_hot_water_efficiency_pct": 50.3, "output_kw_max": 14.7, "final_year_of_manufacture": 2010, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008575", "000005", "0", "2012/Mar/27 10:12", "Baxi Potterton", "Potterton", "Suprima", "50L", "41-590-44", "2001", "2010", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "14.7", "14.7", "", "", "79.0", "68.9", "", "50.3", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.1", "80.1", "", "", "", "", "80.3"]} +{"pcdb_id": 8576, "brand_name": "Potterton", "model_name": "Suprima", "model_qualifier": "60L", "winter_efficiency_pct": 79.0, "summer_efficiency_pct": 68.9, "comparative_hot_water_efficiency_pct": 50.3, "output_kw_max": 17.6, "final_year_of_manufacture": 2010, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008576", "000005", "0", "2012/Mar/27 10:12", "Baxi Potterton", "Potterton", "Suprima", "60L", "41-590-45", "2001", "2010", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "17.6", "17.6", "", "", "79.0", "68.9", "", "50.3", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.1", "80.1", "", "", "", "", "80.3"]} +{"pcdb_id": 8577, "brand_name": "Potterton", "model_name": "Suprima", "model_qualifier": "70L", "winter_efficiency_pct": 79.5, "summer_efficiency_pct": 69.4, "comparative_hot_water_efficiency_pct": 50.7, "output_kw_max": 20.5, "final_year_of_manufacture": 2006, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008577", "000005", "0", "2012/Mar/27 10:12", "Baxi Potterton", "Potterton", "Suprima", "70L", "41-590-46", "2001", "2006", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "20.5", "20.5", "", "", "79.5", "69.4", "", "50.7", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.9", "80.4", "", "", "", "", "80.7"]} +{"pcdb_id": 8578, "brand_name": "Potterton", "model_name": "Suprima", "model_qualifier": "80L", "winter_efficiency_pct": 79.7, "summer_efficiency_pct": 69.6, "comparative_hot_water_efficiency_pct": 50.9, "output_kw_max": 23.4, "final_year_of_manufacture": 2010, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008578", "000005", "0", "2012/Mar/27 10:12", "Baxi Potterton", "Potterton", "Suprima", "80L", "41-590-47", "2001", "2010", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "23.4", "23.4", "", "", "79.7", "69.6", "", "50.9", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.9", "80.7", "", "", "", "", "81.0"]} +{"pcdb_id": 8579, "brand_name": "Potterton", "model_name": "Suprima", "model_qualifier": "100L", "winter_efficiency_pct": 78.9, "summer_efficiency_pct": 68.8, "comparative_hot_water_efficiency_pct": 50.3, "output_kw_max": 28.72, "final_year_of_manufacture": 2006, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008579", "000005", "0", "2012/Mar/27 10:12", "Baxi Potterton", "Potterton", "Suprima", "100L", "41-590-48", "2001", "2006", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "28.72", "28.72", "", "", "78.9", "68.8", "", "50.3", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.1", "79.9", "", "", "", "", "80.1"]} +{"pcdb_id": 8580, "brand_name": "Potterton", "model_name": "Suprima", "model_qualifier": "120L", "winter_efficiency_pct": 79.6, "summer_efficiency_pct": 69.5, "comparative_hot_water_efficiency_pct": 50.8, "output_kw_max": 35.17, "final_year_of_manufacture": 2006, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008580", "000005", "0", "2012/Mar/27 10:12", "Baxi Potterton", "Potterton", "Suprima", "120L", "41-590-49", "2001", "2006", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "35.17", "35.17", "", "", "79.6", "69.5", "", "50.8", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.5", "80.9", "", "", "", "", "81.0"]} +{"pcdb_id": 8581, "brand_name": "Aquaflame", "model_name": "Eco-Avance 30", "model_qualifier": "", "winter_efficiency_pct": 87.0, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 30.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008581", "000039", "0", "2012/Mar/27 10:12", "Aquaflame", "Aquaflame", "Eco-Avance 30", "", "", "2001", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "30.4", "30.4", "", "", "87.0", "79.2", "", "57.8", "", "2", "", "", "201", "1", "1", "100", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.4", "92.3", "", "", "", "", "91.9"]} +{"pcdb_id": 8584, "brand_name": "Aquaflame", "model_name": "Eco-Avance 25", "model_qualifier": "", "winter_efficiency_pct": 87.3, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 24.9, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008584", "000039", "0", "2012/Mar/27 10:12", "Aquaflame", "Aquaflame", "Eco-Avance 25", "", "", "2001", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "24.9", "24.9", "", "", "87.3", "79.5", "", "58.1", "", "2", "", "", "201", "1", "1", "100", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.4", "93.1", "", "", "", "", "92.6"]} +{"pcdb_id": 8585, "brand_name": "Aquaflame", "model_name": "Eco-Avance 28", "model_qualifier": "", "winter_efficiency_pct": 87.4, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 27.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008585", "000039", "0", "2012/Mar/27 10:12", "Aquaflame", "Aquaflame", "Eco-Avance 28", "", "", "2001", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "27.6", "27.6", "", "", "87.4", "79.6", "", "58.2", "", "2", "", "", "201", "1", "1", "100", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.5", "93.4", "", "", "", "", "92.9"]} +{"pcdb_id": 8587, "brand_name": "Worcester", "model_name": "24i - L", "model_qualifier": "RSF", "winter_efficiency_pct": 79.2, "summer_efficiency_pct": 69.1, "comparative_hot_water_efficiency_pct": 48.6, "output_kw_max": 23.4, "final_year_of_manufacture": 2003, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008587", "000035", "0", "2020/Sep/02 14:15", "Worcester Heat Systems", "Worcester", "24i - L", "RSF", "47 311 37", "1998", "2003", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "23.4", "23.4", "", "", "79.2", "69.1", "", "48.6", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.4", "78.3", "", "", "", "", "79.1"]} +{"pcdb_id": 8588, "brand_name": "Worcester", "model_name": "25 Si - L", "model_qualifier": "RSF", "winter_efficiency_pct": 78.9, "summer_efficiency_pct": 68.8, "comparative_hot_water_efficiency_pct": 48.4, "output_kw_max": 25.0, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008588", "000035", "0", "2001/Nov/22 08:37", "Worcester Heat Systems", "Worcester", "25 Si - L", "RSF", "47 311 49", "1999", "2001", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "25", "25", "", "", "78.9", "68.8", "", "48.4", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "83.2", "77.4", "", "", "", "", "78.5"]} +{"pcdb_id": 8589, "brand_name": "Worcester", "model_name": "25 Si - L", "model_qualifier": "RSF", "winter_efficiency_pct": 82.0, "summer_efficiency_pct": 71.9, "comparative_hot_water_efficiency_pct": 50.5, "output_kw_max": 25.0, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008589", "000035", "0", "2002/Feb/26 12:02", "Worcester Heat Systems", "Worcester", "25 Si - L", "RSF", "47 311 50", "1999", "2001", "2", "2", "1", "2", "0", "", "", "1", "2", "2", "25", "25", "", "", "82.0", "71.9", "", "50.5", "", "2", "0", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "86.0", "81.6", "", "", "", "", "82.4"]} +{"pcdb_id": 8591, "brand_name": "Atmos", "model_name": "Atmos Compact System Boiler", "model_qualifier": "N30B", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 24.5, "final_year_of_manufacture": 2006, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008591", "000141", "0", "2012/Mar/27 10:12", "Coopra BV", "Atmos", "Atmos Compact System Boiler", "N30B", "", "1997", "2006", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24.5", "24.5", "", "", "88.7", "79.7", "", "58.2", "", "2", "", "", "102", "1", "2", "65", "10", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.0", "98.0", "", "", "", "", "96.3"]} +{"pcdb_id": 8592, "brand_name": "Atmos", "model_name": "Atmos Compact Combi", "model_qualifier": "N30K", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 56.3, "output_kw_max": 24.5, "final_year_of_manufacture": 2006, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008592", "000141", "0", "2011/Aug/18 10:41", "Coopra BV", "Atmos", "Atmos Compact Combi", "N30K", "", "1997", "2006", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.5", "24.5", "", "", "88.7", "80.1", "", "56.3", "", "2", "", "", "104", "1", "2", "65", "10", "0", "", "", "3.5", "0", "20", "1", "60", "", "0", "", "", "", "", "", "", "", "", "", "1", "0", "", "0005", "", "", "", "", "", "", "", "", "89.0", "98.0", "", "", "", "", "96.3"]} +{"pcdb_id": 8593, "brand_name": "Atmos", "model_name": "Atmos Compact Boiler", "model_qualifier": "N30C", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 24.5, "final_year_of_manufacture": 2006, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008593", "000141", "0", "2012/Mar/27 10:12", "Coopra BV", "Atmos", "Atmos Compact Boiler", "N30C", "", "1997", "2006", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24.5", "24.5", "", "", "88.7", "79.7", "", "58.2", "", "2", "", "", "102", "1", "2", "65", "10", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.0", "98.0", "", "", "", "", "96.3"]} +{"pcdb_id": 8594, "brand_name": "Worcester", "model_name": "28 CDi", "model_qualifier": "RSF", "winter_efficiency_pct": 80.8, "summer_efficiency_pct": 70.7, "comparative_hot_water_efficiency_pct": 49.7, "output_kw_max": 24.0, "final_year_of_manufacture": 2002, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008594", "000035", "0", "2006/Jan/17 12:55", "Worcester Heat Systems", "Worcester", "28 CDi", "RSF", "47 311 35", "1997", "2002", "2", "2", "1", "2", "0", "", "", "1", "2", "2", "24.0", "24.0", "", "", "80.8", "70.7", "", "49.7", "", "2", "0", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "84.3", "79.7", "", "", "", "", "80.5"]} +{"pcdb_id": 8595, "brand_name": "Boulter", "model_name": "Pathfinder GA", "model_qualifier": "36 kW", "winter_efficiency_pct": 80.2, "summer_efficiency_pct": 70.1, "comparative_hot_water_efficiency_pct": 51.2, "output_kw_max": 36.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008595", "000041", "0", "2012/Mar/27 10:12", "Boulter Boilers", "Boulter", "Pathfinder GA", "36 kW", "", "2001", "obsolete", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "36", "36", "", "", "80.2", "70.1", "", "51.2", "", "2", "", "", "101", "1", "1", "10", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.8", "81.8", "", "", "", "", "81.8"]} +{"pcdb_id": 8596, "brand_name": "Boulter", "model_name": "Pathfinder GA", "model_qualifier": "48 kW", "winter_efficiency_pct": 80.5, "summer_efficiency_pct": 70.4, "comparative_hot_water_efficiency_pct": 51.4, "output_kw_max": 48.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008596", "000041", "0", "2012/Mar/27 10:12", "Boulter Boilers", "Boulter", "Pathfinder GA", "48 kW", "", "2001", "obsolete", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "48", "48", "", "", "80.5", "70.4", "", "51.4", "", "2", "", "", "101", "1", "1", "10", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.7", "81.5", "", "", "", "", "81.7"]} +{"pcdb_id": 8597, "brand_name": "Sime", "model_name": "Format 100 C", "model_qualifier": "", "winter_efficiency_pct": 80.1, "summer_efficiency_pct": 70.0, "comparative_hot_water_efficiency_pct": 49.2, "output_kw_max": 28.8, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008597", "000213", "0", "2018/Feb/26 16:57", "Fonderie Sime S.p.A.", "Sime", "Format 100 C", "", "", "2001", "2018", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "28.8", "28.8", "", "", "80.1", "70.0", "", "49.2", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.0", "80.5", "", "", "", "", "80.8"]} +{"pcdb_id": 8598, "brand_name": "Sime", "model_name": "Format 80 C", "model_qualifier": "", "winter_efficiency_pct": 79.9, "summer_efficiency_pct": 69.8, "comparative_hot_water_efficiency_pct": 49.1, "output_kw_max": 23.4, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008598", "000213", "0", "2018/Feb/26 17:05", "Fonderie Sime S.p.A.", "Sime", "Format 80 C", "", "", "2001", "2018", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "23.4", "23.4", "", "", "79.9", "69.8", "", "49.1", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.7", "80.5", "", "", "", "", "80.8"]} +{"pcdb_id": 8599, "brand_name": "Sime", "model_name": "Planet Super 4 W.M", "model_qualifier": "", "winter_efficiency_pct": 81.9, "summer_efficiency_pct": 72.8, "comparative_hot_water_efficiency_pct": 39.1, "output_kw_max": 29.5, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008599", "000213", "0", "2024/Jan/31 10:17", "Fonderie Sime S.p.A.", "Sime", "Planet Super 4 W.M", "", "", "2001", "2018", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "29.50", "29.50", "", "", "81.9", "72.8", "", "39.1", "", "2", "", "", "106", "1", "2", "", "", "2", "1", "0", "65", "0", "18", "2", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "84.2", "82.8", "", "", "", "", "83.1"]} +{"pcdb_id": 8600, "brand_name": "Sime", "model_name": "Superior 90 MK.II", "model_qualifier": "", "winter_efficiency_pct": 77.7, "summer_efficiency_pct": 67.6, "comparative_hot_water_efficiency_pct": 49.4, "output_kw_max": 25.5, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008600", "000213", "0", "2018/Mar/05 15:14", "Fonderie Sime S.p.A.", "Sime", "Superior 90 MK.II", "", "", "2000", "2018", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "22", "25.5", "", "", "77.7", "67.6", "", "49.4", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "80.1", "78.5", "", "", "", "", "78.8"]} +{"pcdb_id": 8601, "brand_name": "Sime", "model_name": "Superior 75 MK.II", "model_qualifier": "", "winter_efficiency_pct": 77.4, "summer_efficiency_pct": 67.3, "comparative_hot_water_efficiency_pct": 49.2, "output_kw_max": 22.0, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008601", "000213", "0", "2018/Mar/05 15:13", "Fonderie Sime S.p.A.", "Sime", "Superior 75 MK.II", "", "", "2000", "2018", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "17.6", "22.0", "", "", "77.4", "67.3", "", "49.2", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.6", "78.4", "", "", "", "", "78.6"]} +{"pcdb_id": 8602, "brand_name": "Sime", "model_name": "Superior 60 MK.II", "model_qualifier": "", "winter_efficiency_pct": 76.6, "summer_efficiency_pct": 66.5, "comparative_hot_water_efficiency_pct": 48.6, "output_kw_max": 17.7, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008602", "000213", "0", "2018/Mar/05 15:12", "Fonderie Sime S.p.A.", "Sime", "Superior 60 MK.II", "", "", "2000", "2018", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "14.4", "17.7", "", "", "76.6", "66.5", "", "48.6", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.0", "77.4", "", "", "", "", "77.7"]} +{"pcdb_id": 8603, "brand_name": "Sime", "model_name": "Superior 50 MK.II", "model_qualifier": "", "winter_efficiency_pct": 77.2, "summer_efficiency_pct": 67.1, "comparative_hot_water_efficiency_pct": 49.0, "output_kw_max": 14.6, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008603", "000213", "0", "2018/Mar/05 15:11", "Fonderie Sime S.p.A.", "Sime", "Superior 50 MK.II", "", "", "2000", "2018", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "11.5", "14.6", "", "", "77.2", "67.1", "", "49.0", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.1", "78.5", "", "", "", "", "78.6"]} +{"pcdb_id": 8604, "brand_name": "Sime", "model_name": "Superior 40 MK.II", "model_qualifier": "", "winter_efficiency_pct": 77.0, "summer_efficiency_pct": 66.9, "comparative_hot_water_efficiency_pct": 48.8, "output_kw_max": 11.9, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008604", "000213", "0", "2018/Mar/05 15:10", "Fonderie Sime S.p.A.", "Sime", "Superior 40 MK.II", "", "", "2001", "2018", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "8.7", "11.9", "", "", "77.0", "66.9", "", "48.8", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "79.2", "77.9", "", "", "", "", "78.2"]} +{"pcdb_id": 8605, "brand_name": "Sime", "model_name": "Planet Dewy 90", "model_qualifier": "", "winter_efficiency_pct": 87.4, "summer_efficiency_pct": 78.8, "comparative_hot_water_efficiency_pct": 55.4, "output_kw_max": 29.3, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008605", "000213", "0", "2018/Mar/05 14:30", "Fonderie Sime S.p.A.", "Sime", "Planet Dewy 90", "", "", "2000", "2018", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "29.3", "29.3", "", "", "87.4", "78.8", "", "55.4", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.0", "95.7", "", "", "", "", "94.0"]} +{"pcdb_id": 8606, "brand_name": "Sime", "model_name": "Planet Dewy 110", "model_qualifier": "", "winter_efficiency_pct": 87.7, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 55.6, "output_kw_max": 29.3, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008606", "000213", "0", "2018/Mar/05 14:27", "Fonderie Sime S.p.A.", "Sime", "Planet Dewy 110", "", "", "2000", "2018", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "29.3", "29.3", "", "", "87.7", "79.1", "", "55.6", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "96.0", "", "", "", "", "94.5"]} +{"pcdb_id": 8607, "brand_name": "Sime", "model_name": "Friendly Format 100E", "model_qualifier": "", "winter_efficiency_pct": 79.5, "summer_efficiency_pct": 69.4, "comparative_hot_water_efficiency_pct": 48.8, "output_kw_max": 29.0, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008607", "000213", "0", "2018/Mar/05 14:08", "Fonderie Sime S.p.A.", "Sime", "Friendly Format 100E", "", "", "1999", "2018", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "29", "29", "", "", "79.5", "69.4", "", "48.8", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.9", "78.6", "", "", "", "", "79.4"]} +{"pcdb_id": 8608, "brand_name": "Sime", "model_name": "Super 90 MK.II", "model_qualifier": "", "winter_efficiency_pct": 80.2, "summer_efficiency_pct": 70.1, "comparative_hot_water_efficiency_pct": 49.3, "output_kw_max": 23.68, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008608", "000213", "0", "2018/Mar/05 15:08", "Fonderie Sime S.p.A.", "Sime", "Super 90 MK.II", "", "", "2000", "2018", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "23.68", "23.68", "", "", "80.2", "70.1", "", "49.3", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.7", "80.1", "", "", "", "", "80.6"]} +{"pcdb_id": 8609, "brand_name": "Sime", "model_name": "Super 105 MK II", "model_qualifier": "", "winter_efficiency_pct": 79.5, "summer_efficiency_pct": 69.4, "comparative_hot_water_efficiency_pct": 48.8, "output_kw_max": 30.5, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008609", "000213", "0", "2018/Mar/05 15:05", "Fonderie Sime S.p.A.", "Sime", "Super 105 MK II", "", "", "2000", "2018", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "30.5", "30.5", "", "", "79.5", "69.4", "", "48.8", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.9", "78.6", "", "", "", "", "79.4"]} +{"pcdb_id": 8613, "brand_name": "Boulter", "model_name": "Pathfinder GA", "model_qualifier": "70kW", "winter_efficiency_pct": 80.4, "summer_efficiency_pct": 70.3, "comparative_hot_water_efficiency_pct": 51.3, "output_kw_max": 70.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008613", "000041", "0", "2012/Mar/27 10:12", "Boulter Boilers", "Boulter", "Pathfinder GA", "70kW", "", "2001", "obsolete", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "70", "70", "", "", "80.4", "70.3", "", "51.3", "", "2", "", "", "101", "1", "1", "10", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.6", "81.4", "", "", "", "", "81.6"]} +{"pcdb_id": 8614, "brand_name": "Boulter", "model_name": "Pathfinder GA", "model_qualifier": "60kW", "winter_efficiency_pct": 80.5, "summer_efficiency_pct": 70.4, "comparative_hot_water_efficiency_pct": 51.4, "output_kw_max": 60.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008614", "000041", "0", "2012/Mar/27 10:12", "Boulter Boilers", "Boulter", "Pathfinder GA", "60kW", "", "2001", "obsolete", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "60", "60", "", "", "80.5", "70.4", "", "51.4", "", "2", "", "", "101", "1", "1", "10", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.6", "81.6", "", "", "", "", "81.8"]} +{"pcdb_id": 8620, "brand_name": "Worcester", "model_name": "Greenstar HE 12/22", "model_qualifier": "RS", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 78.9, "comparative_hot_water_efficiency_pct": 57.6, "output_kw_max": 21.1, "final_year_of_manufacture": 2008, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008620", "000035", "0", "2020/Sep/02 14:16", "Worcester Heat Systems", "Worcester", "Greenstar HE 12/22", "RS", "49AS036R", "2001", "2008", "4", "1", "1", "1", "0", "", "", "2", "2", "2", "14.1", "21.1", "", "", "86.7", "78.9", "", "57.6", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "89.3", "92.2", "", "", "", "", "91.6"]} +{"pcdb_id": 8621, "brand_name": "Boulter", "model_name": "Camray 5", "model_qualifier": "150/200K", "winter_efficiency_pct": 85.3, "summer_efficiency_pct": 73.6, "comparative_hot_water_efficiency_pct": 53.7, "output_kw_max": 58.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008621", "000041", "0", "2012/Mar/27 10:12", "Boulter Boilers", "Boulter", "Camray 5", "150/200K", "", "2001", "current", "4", "1", "1", "1", "0", "", "", "1", "3", "2", "44", "58.6", "", "", "85.3", "73.6", "", "53.7", "", "2", "", "", "201", "1", "1", "150", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.3", "85.3", "", "", "", "", "85.3"]} +{"pcdb_id": 8623, "brand_name": "Ikon", "model_name": "23 t", "model_qualifier": "", "winter_efficiency_pct": 79.6, "summer_efficiency_pct": 69.5, "comparative_hot_water_efficiency_pct": 48.9, "output_kw_max": 23.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008623", "000020", "0", "2006/Jan/17 12:31", "Hermann Srl", "Ikon", "23 t", "", "GC 47-047-11", "2001", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "23.3", "23.3", "", "", "79.6", "69.5", "", "48.9", "", "2", "", "", "104", "1", "2", "150", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "83.0", "78.7", "", "", "", "", "79.6"]} +{"pcdb_id": 8624, "brand_name": "Ikon", "model_name": "28 t", "model_qualifier": "", "winter_efficiency_pct": 80.8, "summer_efficiency_pct": 70.7, "comparative_hot_water_efficiency_pct": 49.7, "output_kw_max": 28.1, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008624", "000020", "0", "2006/Jan/17 12:31", "Hermann Srl", "Ikon", "28 t", "", "GC 47-047-12", "2001", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "28.1", "28.1", "", "", "80.8", "70.7", "", "49.7", "", "2", "", "", "104", "1", "2", "157", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "83.2", "81.1", "", "", "", "", "81.5"]} +{"pcdb_id": 8625, "brand_name": "Worcester", "model_name": "35 CDi II", "model_qualifier": "RSF", "winter_efficiency_pct": 79.4, "summer_efficiency_pct": 69.3, "comparative_hot_water_efficiency_pct": 48.7, "output_kw_max": 27.5, "final_year_of_manufacture": 2005, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008625", "000035", "0", "2020/Sep/02 14:16", "Worcester Heat Systems", "Worcester", "35 CDi II", "RSF", "47 311 58", "2001", "2005", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "27.5", "27.5", "", "", "79.4", "69.3", "", "48.7", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.3", "78.9", "", "", "", "", "79.6"]} +{"pcdb_id": 8626, "brand_name": "Worcester", "model_name": "35 CDi II", "model_qualifier": "RSF", "winter_efficiency_pct": 81.3, "summer_efficiency_pct": 71.2, "comparative_hot_water_efficiency_pct": 50.1, "output_kw_max": 27.5, "final_year_of_manufacture": 2005, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008626", "000035", "0", "2020/Sep/02 14:16", "Worcester Heat Systems", "Worcester", "35 CDi II", "RSF", "47 311 59", "2001", "2005", "2", "2", "1", "2", "0", "", "", "1", "2", "2", "27.5", "27.5", "", "", "81.3", "71.2", "", "50.1", "", "2", "0", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "84.2", "80.8", "", "", "", "", "81.4"]} +{"pcdb_id": 8627, "brand_name": "Firebird", "model_name": "Popular", "model_qualifier": "50-70", "winter_efficiency_pct": 85.0, "summer_efficiency_pct": 73.3, "comparative_hot_water_efficiency_pct": 53.6, "output_kw_max": 20.52, "final_year_of_manufacture": 2013, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008627", "000047", "0", "2018/Jan/03 13:34", "Firebird Boilers", "Firebird", "Popular", "50-70", "", "", "2013", "4", "1", "1", "1", "0", "", "", "1", "2", "1", "14.65", "20.52", "", "", "85.0", "73.3", "", "53.6", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.5", "84.6", "", "", "", "", "84.8"]} +{"pcdb_id": 8628, "brand_name": "Firebird", "model_name": "Popular", "model_qualifier": "50-90", "winter_efficiency_pct": 86.1, "summer_efficiency_pct": 74.4, "comparative_hot_water_efficiency_pct": 54.4, "output_kw_max": 26.38, "final_year_of_manufacture": 2013, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008628", "000047", "0", "2018/Jan/03 13:29", "Firebird Boilers", "Firebird", "Popular", "50-90", "", "", "2013", "4", "1", "1", "1", "0", "", "", "1", "2", "1", "14.65", "26.38", "", "", "86.1", "74.4", "", "54.4", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.8", "86.4", "", "", "", "", "86.3"]} +{"pcdb_id": 8629, "brand_name": "Firebird", "model_name": "Combi", "model_qualifier": "115", "winter_efficiency_pct": 84.0, "summer_efficiency_pct": 75.9, "comparative_hot_water_efficiency_pct": 43.2, "output_kw_max": 33.7, "final_year_of_manufacture": 2010, "subsidiary_type": 0, "store_type": 1, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008629", "000047", "0", "2024/Jan/31 10:17", "Firebird Boilers", "Firebird", "Combi", "115", "", "1997", "2010", "4", "1", "1", "2", "0", "", "", "1", "2", "1", "33.7", "33.7", "", "", "84.0", "75.9", "", "43.2", "", "2", "", "", "203", "1", "1", "138", "0", "1", "2", "0", "25", "0", "25", "3", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.1", "85.5", "", "", "", "", "85.7"]} +{"pcdb_id": 8630, "brand_name": "Firebird", "model_name": "Combi", "model_qualifier": "90", "winter_efficiency_pct": 84.2, "summer_efficiency_pct": 76.1, "comparative_hot_water_efficiency_pct": 43.4, "output_kw_max": 26.38, "final_year_of_manufacture": 2013, "subsidiary_type": 0, "store_type": 1, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008630", "000047", "0", "2024/Jan/31 10:17", "Firebird Boilers", "Firebird", "Combi", "90", "", "1997", "2013", "4", "1", "1", "2", "0", "", "", "1", "2", "1", "26.38", "26.38", "", "", "84.2", "76.1", "", "43.4", "", "2", "", "", "203", "1", "1", "138", "0", "1", "2", "0", "25", "0", "25", "3", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.6", "85.9", "", "", "", "", "86.0"]} +{"pcdb_id": 8631, "brand_name": "Firebird", "model_name": "Oylympic S", "model_qualifier": "50-70", "winter_efficiency_pct": 85.0, "summer_efficiency_pct": 73.3, "comparative_hot_water_efficiency_pct": 53.6, "output_kw_max": 20.52, "final_year_of_manufacture": 2010, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008631", "000047", "0", "2012/Mar/27 10:12", "Firebird Boilers", "Firebird", "Oylympic S", "50-70", "", "", "2010", "4", "1", "1", "1", "0", "", "", "1", "2", "1", "14.65", "20.52", "", "", "85.0", "73.3", "", "53.6", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.5", "84.6", "", "", "", "", "84.8"]} +{"pcdb_id": 8632, "brand_name": "Firebird", "model_name": "Oylympic DeLuxe", "model_qualifier": "50-70", "winter_efficiency_pct": 85.0, "summer_efficiency_pct": 73.3, "comparative_hot_water_efficiency_pct": 53.6, "output_kw_max": 20.52, "final_year_of_manufacture": 2010, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008632", "000047", "0", "2012/Mar/27 10:12", "Firebird Boilers", "Firebird", "Oylympic DeLuxe", "50-70", "", "", "2010", "4", "1", "1", "1", "0", "", "", "1", "2", "1", "14.65", "20.52", "", "", "85.0", "73.3", "", "53.6", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.5", "84.6", "", "", "", "", "84.8"]} +{"pcdb_id": 8633, "brand_name": "Firebird", "model_name": "Oylympic Boilerhouse", "model_qualifier": "50 - 70", "winter_efficiency_pct": 85.0, "summer_efficiency_pct": 73.3, "comparative_hot_water_efficiency_pct": 53.6, "output_kw_max": 20.52, "final_year_of_manufacture": 2010, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008633", "000047", "0", "2012/Mar/27 10:12", "Firebird Boilers", "Firebird", "Oylympic Boilerhouse", "50 - 70", "", "", "2010", "4", "1", "1", "1", "0", "", "", "1", "2", "1", "14.65", "20.52", "", "", "85.0", "73.3", "", "53.6", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.5", "84.6", "", "", "", "", "84.8"]} +{"pcdb_id": 8634, "brand_name": "Firebird", "model_name": "Roomsealed Popular (Hideaway)", "model_qualifier": "50 - 90", "winter_efficiency_pct": 86.1, "summer_efficiency_pct": 74.4, "comparative_hot_water_efficiency_pct": 54.4, "output_kw_max": 26.38, "final_year_of_manufacture": 2010, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008634", "000047", "0", "2012/Mar/27 10:12", "Firebird Boilers", "Firebird", "Roomsealed Popular (Hideaway)", "50 - 90", "", "", "2010", "4", "1", "1", "1", "0", "", "", "1", "2", "1", "14.65", "26.38", "", "", "86.1", "74.4", "", "54.4", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.8", "86.4", "", "", "", "", "86.3"]} +{"pcdb_id": 8635, "brand_name": "Firebird", "model_name": "Oylympic S", "model_qualifier": "70-90", "winter_efficiency_pct": 86.1, "summer_efficiency_pct": 74.4, "comparative_hot_water_efficiency_pct": 54.4, "output_kw_max": 26.38, "final_year_of_manufacture": 2010, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008635", "000047", "0", "2012/Mar/27 10:12", "Firebird Boilers", "Firebird", "Oylympic S", "70-90", "", "", "2010", "4", "1", "1", "1", "0", "", "", "1", "2", "1", "20.52", "26.38", "", "", "86.1", "74.4", "", "54.4", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.8", "86.4", "", "", "", "", "86.3"]} +{"pcdb_id": 8636, "brand_name": "Firebird", "model_name": "Oylympic Deluxe", "model_qualifier": "70-90", "winter_efficiency_pct": 86.1, "summer_efficiency_pct": 74.4, "comparative_hot_water_efficiency_pct": 54.4, "output_kw_max": 26.38, "final_year_of_manufacture": 2010, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008636", "000047", "0", "2012/Mar/27 10:12", "Firebird Boilers", "Firebird", "Oylympic Deluxe", "70-90", "", "", "2010", "4", "1", "1", "1", "0", "", "", "1", "2", "1", "20.52", "26.38", "", "", "86.1", "74.4", "", "54.4", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.8", "86.4", "", "", "", "", "86.3"]} +{"pcdb_id": 8637, "brand_name": "Firebird", "model_name": "Oylympic Boilerhouse", "model_qualifier": "70 - 90", "winter_efficiency_pct": 86.1, "summer_efficiency_pct": 74.4, "comparative_hot_water_efficiency_pct": 54.4, "output_kw_max": 26.38, "final_year_of_manufacture": 2010, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008637", "000047", "0", "2012/Mar/27 10:12", "Firebird Boilers", "Firebird", "Oylympic Boilerhouse", "70 - 90", "", "", "2010", "4", "1", "1", "1", "0", "", "", "1", "2", "1", "20.52", "26.38", "", "", "86.1", "74.4", "", "54.4", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.8", "86.4", "", "", "", "", "86.3"]} +{"pcdb_id": 8638, "brand_name": "Ideal", "model_name": "Classic", "model_qualifier": "FF 3100", "winter_efficiency_pct": 78.9, "summer_efficiency_pct": 68.8, "comparative_hot_water_efficiency_pct": 50.3, "output_kw_max": 29.3, "final_year_of_manufacture": 2004, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008638", "000008", "0", "2012/Mar/27 10:12", "Ideal Boilers", "Ideal", "Classic", "FF 3100", "GC No. 41 391 01", "2001", "2004", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "29.3", "29.3", "", "", "78.9", "68.8", "", "50.3", "", "2", "", "", "101", "1", "1", "100", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "80.5", "80.5", "", "", "", "", "80.5"]} +{"pcdb_id": 8639, "brand_name": "Ideal", "model_name": "Classic", "model_qualifier": "FF 380", "winter_efficiency_pct": 79.0, "summer_efficiency_pct": 68.9, "comparative_hot_water_efficiency_pct": 50.3, "output_kw_max": 23.4, "final_year_of_manufacture": 2004, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008639", "000008", "0", "2012/Mar/27 10:12", "Ideal Boilers", "Ideal", "Classic", "FF 380", "GC No. 41 391 99", "2001", "2004", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "23.4", "23.4", "", "", "79.0", "68.9", "", "50.3", "", "2", "", "", "101", "1", "1", "100", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "80.6", "80.5", "", "", "", "", "80.6"]} +{"pcdb_id": 8640, "brand_name": "Ideal", "model_name": "Classic", "model_qualifier": "FF 370", "winter_efficiency_pct": 79.4, "summer_efficiency_pct": 69.3, "comparative_hot_water_efficiency_pct": 50.6, "output_kw_max": 20.5, "final_year_of_manufacture": 2004, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008640", "000008", "0", "2012/Mar/27 10:12", "Ideal Boilers", "Ideal", "Classic", "FF 370", "GC No. 41 391 98", "2001", "2004", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "20.5", "20.5", "", "", "79.4", "69.3", "", "50.6", "", "2", "", "", "101", "1", "1", "100", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.2", "80.8", "", "", "", "", "80.9"]} +{"pcdb_id": 8641, "brand_name": "Ideal", "model_name": "Classic", "model_qualifier": "FF 360", "winter_efficiency_pct": 79.2, "summer_efficiency_pct": 69.1, "comparative_hot_water_efficiency_pct": 50.5, "output_kw_max": 17.6, "final_year_of_manufacture": 2004, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008641", "000008", "0", "2012/Mar/27 10:12", "Ideal Boilers", "Ideal", "Classic", "FF 360", "GC No. 41 391 97", "2001", "2004", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "17.6", "17.6", "", "", "79.2", "69.1", "", "50.5", "", "2", "", "", "101", "1", "1", "100", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "80.8", "80.7", "", "", "", "", "80.7"]} +{"pcdb_id": 8642, "brand_name": "Ideal", "model_name": "Classic", "model_qualifier": "FF 350", "winter_efficiency_pct": 80.7, "summer_efficiency_pct": 70.6, "comparative_hot_water_efficiency_pct": 51.5, "output_kw_max": 14.7, "final_year_of_manufacture": 2004, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008642", "000008", "0", "2012/Mar/27 10:12", "Ideal Boilers", "Ideal", "Classic", "FF 350", "GC No. 41 391 96", "2001", "2004", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "14.7", "14.7", "", "", "80.7", "70.6", "", "51.5", "", "2", "", "", "101", "1", "1", "100", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.3", "82.3", "", "", "", "", "82.3"]} +{"pcdb_id": 8643, "brand_name": "Ideal", "model_name": "Classic", "model_qualifier": "FF 340", "winter_efficiency_pct": 79.5, "summer_efficiency_pct": 69.4, "comparative_hot_water_efficiency_pct": 50.7, "output_kw_max": 11.7, "final_year_of_manufacture": 2004, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008643", "000008", "0", "2012/Mar/27 10:12", "Ideal Boilers", "Ideal", "Classic", "FF 340", "GC No. 41 391 95", "2001", "2004", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "11.7", "11.7", "", "", "79.5", "69.4", "", "50.7", "", "2", "", "", "101", "1", "1", "100", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.0", "81.3", "", "", "", "", "81.2"]} +{"pcdb_id": 8644, "brand_name": "Ideal", "model_name": "Classic", "model_qualifier": "FF 330", "winter_efficiency_pct": 80.4, "summer_efficiency_pct": 70.3, "comparative_hot_water_efficiency_pct": 51.4, "output_kw_max": 8.8, "final_year_of_manufacture": 2004, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008644", "000008", "0", "2012/Mar/27 10:12", "Ideal Boilers", "Ideal", "Classic", "FF 330", "GC No. 41 391 54", "2001", "2004", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "8.8", "8.8", "", "", "80.4", "70.3", "", "51.4", "", "2", "", "", "101", "1", "1", "100", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.9", "82.2", "", "", "", "", "82.1"]} +{"pcdb_id": 8645, "brand_name": "Ideal", "model_name": "Classic", "model_qualifier": "FF 360 LF", "winter_efficiency_pct": 80.0, "summer_efficiency_pct": 69.9, "comparative_hot_water_efficiency_pct": 51.1, "output_kw_max": 17.6, "final_year_of_manufacture": 2003, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008645", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "Classic", "FF 360 LF", "GC No. 41 392 92", "2001", "2003", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "17.6", "17.6", "", "", "80.0", "69.9", "", "51.1", "", "2", "", "", "101", "1", "1", "100", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.9", "81.4", "", "", "", "", "81.5"]} +{"pcdb_id": 8646, "brand_name": "Ideal", "model_name": "Classic", "model_qualifier": "FF 350 LF", "winter_efficiency_pct": 79.3, "summer_efficiency_pct": 69.2, "comparative_hot_water_efficiency_pct": 50.6, "output_kw_max": 14.7, "final_year_of_manufacture": 2003, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008646", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "Classic", "FF 350 LF", "GC No. 41 392 91", "2001", "2003", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "14.7", "14.7", "", "", "79.3", "69.2", "", "50.6", "", "2", "", "", "101", "1", "1", "100", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.1", "80.7", "", "", "", "", "80.8"]} +{"pcdb_id": 8647, "brand_name": "Ideal", "model_name": "Classic", "model_qualifier": "FF 340 LF", "winter_efficiency_pct": 80.0, "summer_efficiency_pct": 69.9, "comparative_hot_water_efficiency_pct": 51.0, "output_kw_max": 11.7, "final_year_of_manufacture": 2003, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008647", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "Classic", "FF 340 LF", "GC No. 41 392 90", "2001", "2003", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "11.7", "11.7", "", "", "80.0", "69.9", "", "51.0", "", "2", "", "", "101", "1", "1", "100", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.7", "81.5", "", "", "", "", "81.5"]} +{"pcdb_id": 8648, "brand_name": "Ideal", "model_name": "Classic", "model_qualifier": "FF 380 P", "winter_efficiency_pct": 80.8, "summer_efficiency_pct": 70.7, "comparative_hot_water_efficiency_pct": 51.6, "output_kw_max": 23.5, "final_year_of_manufacture": 2004, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008648", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "Classic", "FF 380 P", "GC No. 41 392 08", "2001", "2004", "2", "2", "1", "1", "0", "", "", "1", "2", "2", "23.5", "23.5", "", "", "80.8", "70.7", "", "51.6", "", "2", "0", "", "101", "1", "1", "100", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.4", "82.3", "", "", "", "", "82.4"]} +{"pcdb_id": 8649, "brand_name": "Ideal", "model_name": "Classic", "model_qualifier": "FF 360 P", "winter_efficiency_pct": 81.1, "summer_efficiency_pct": 71.0, "comparative_hot_water_efficiency_pct": 51.9, "output_kw_max": 17.6, "final_year_of_manufacture": 2004, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008649", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "Classic", "FF 360 P", "GC No. 41 392 07", "2001", "2004", "2", "2", "1", "1", "0", "", "", "1", "2", "2", "17.6", "17.6", "", "", "81.1", "71.0", "", "51.9", "", "2", "0", "", "101", "1", "1", "100", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.9", "82.5", "", "", "", "", "82.6"]} +{"pcdb_id": 8650, "brand_name": "Ideal", "model_name": "Classic", "model_qualifier": "FF 350 P", "winter_efficiency_pct": 82.7, "summer_efficiency_pct": 72.6, "comparative_hot_water_efficiency_pct": 53.0, "output_kw_max": 14.7, "final_year_of_manufacture": 2004, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008650", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "Classic", "FF 350 P", "GC No. 41 392 06", "2001", "2004", "2", "2", "1", "1", "0", "", "", "1", "2", "2", "14.7", "14.7", "", "", "82.7", "72.6", "", "53.0", "", "2", "0", "", "101", "1", "1", "100", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "84.7", "84.1", "", "", "", "", "84.2"]} +{"pcdb_id": 8651, "brand_name": "Ideal", "model_name": "Classic Slimline", "model_qualifier": "FF 360", "winter_efficiency_pct": 80.8, "summer_efficiency_pct": 70.7, "comparative_hot_water_efficiency_pct": 51.6, "output_kw_max": 17.6, "final_year_of_manufacture": 2004, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008651", "000008", "0", "2012/Mar/27 10:12", "Ideal Boilers", "Ideal", "Classic Slimline", "FF 360", "GC No. 41 392 05", "2001", "2004", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "17.6", "17.6", "", "", "80.8", "70.7", "", "51.6", "", "2", "", "", "101", "1", "1", "100", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.4", "82.4", "", "", "", "", "82.4"]} +{"pcdb_id": 8652, "brand_name": "Ideal", "model_name": "Classic Slimline", "model_qualifier": "FF 350", "winter_efficiency_pct": 81.4, "summer_efficiency_pct": 71.3, "comparative_hot_water_efficiency_pct": 52.1, "output_kw_max": 14.7, "final_year_of_manufacture": 2004, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008652", "000008", "0", "2012/Mar/27 10:12", "Ideal Boilers", "Ideal", "Classic Slimline", "FF 350", "GC No. 41 392 04", "2001", "2004", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "14.7", "14.7", "", "", "81.4", "71.3", "", "52.1", "", "2", "", "", "101", "1", "1", "100", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "83.0", "83.1", "", "", "", "", "83.1"]} +{"pcdb_id": 8653, "brand_name": "Ideal", "model_name": "Classic Slimline", "model_qualifier": "FF 340", "winter_efficiency_pct": 80.1, "summer_efficiency_pct": 70.0, "comparative_hot_water_efficiency_pct": 51.1, "output_kw_max": 11.7, "final_year_of_manufacture": 2004, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008653", "000008", "0", "2012/Mar/27 10:12", "Ideal Boilers", "Ideal", "Classic Slimline", "FF 340", "GC No. 41 392 03", "2001", "2004", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "11.7", "11.7", "", "", "80.1", "70.0", "", "51.1", "", "2", "", "", "101", "1", "1", "100", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.8", "81.5", "", "", "", "", "81.6"]} +{"pcdb_id": 8654, "brand_name": "Ideal", "model_name": "Classic Slimline", "model_qualifier": "FF 330", "winter_efficiency_pct": 81.6, "summer_efficiency_pct": 71.5, "comparative_hot_water_efficiency_pct": 52.2, "output_kw_max": 8.8, "final_year_of_manufacture": 2004, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008654", "000008", "0", "2012/Mar/27 10:12", "Ideal Boilers", "Ideal", "Classic Slimline", "FF 330", "GC No. 41 392 02", "2001", "2004", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "8.8", "8.8", "", "", "81.6", "71.5", "", "52.2", "", "2", "", "", "101", "1", "1", "100", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "83.1", "83.4", "", "", "", "", "83.4"]} +{"pcdb_id": 8655, "brand_name": "Ideal", "model_name": "Mexico Super", "model_qualifier": "4125 FF", "winter_efficiency_pct": 79.4, "summer_efficiency_pct": 69.3, "comparative_hot_water_efficiency_pct": 50.7, "output_kw_max": 36.6, "final_year_of_manufacture": 2006, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008655", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "Mexico Super", "4125 FF", "GC No. 41 392 32", "2001", "2006", "1", "1", "1", "1", "0", "", "", "1", "2", "2", "36.6", "36.6", "", "", "79.4", "69.3", "", "50.7", "", "2", "", "", "101", "1", "1", "100", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "80.9", "81.2", "", "", "", "", "81.1"]} +{"pcdb_id": 8656, "brand_name": "Ideal", "model_name": "Mexico Super", "model_qualifier": "4100 FF", "winter_efficiency_pct": 79.8, "summer_efficiency_pct": 69.7, "comparative_hot_water_efficiency_pct": 50.9, "output_kw_max": 29.3, "final_year_of_manufacture": 2006, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008656", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "Mexico Super", "4100 FF", "GC No. 41 392 31", "2001", "2006", "1", "1", "1", "1", "0", "", "", "1", "2", "2", "29.3", "29.3", "", "", "79.8", "69.7", "", "50.9", "", "2", "", "", "101", "1", "1", "100", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.5", "81.3", "", "", "", "", "81.3"]} +{"pcdb_id": 8657, "brand_name": "Ideal", "model_name": "Mexico Super", "model_qualifier": "480 FF", "winter_efficiency_pct": 80.8, "summer_efficiency_pct": 70.7, "comparative_hot_water_efficiency_pct": 51.7, "output_kw_max": 23.4, "final_year_of_manufacture": 2006, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008657", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "Mexico Super", "480 FF", "GC No. 41 392 30", "2001", "2006", "1", "1", "1", "1", "0", "", "", "1", "2", "2", "23.4", "23.4", "", "", "80.8", "70.7", "", "51.7", "", "2", "", "", "101", "1", "1", "100", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.4", "82.5", "", "", "", "", "82.5"]} +{"pcdb_id": 8658, "brand_name": "Ideal", "model_name": "Mexico Super", "model_qualifier": "470 FF", "winter_efficiency_pct": 81.4, "summer_efficiency_pct": 71.3, "comparative_hot_water_efficiency_pct": 52.1, "output_kw_max": 20.5, "final_year_of_manufacture": 2006, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008658", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "Mexico Super", "470 FF", "GC No. 41 392 29", "2001", "2006", "1", "1", "1", "1", "0", "", "", "1", "2", "2", "20.5", "20.5", "", "", "81.4", "71.3", "", "52.1", "", "2", "", "", "101", "1", "1", "100", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "83.2", "83.2", "", "", "", "", "83.2"]} +{"pcdb_id": 8659, "brand_name": "Ideal", "model_name": "Mexico Super", "model_qualifier": "460 FF", "winter_efficiency_pct": 80.1, "summer_efficiency_pct": 70.0, "comparative_hot_water_efficiency_pct": 51.1, "output_kw_max": 17.6, "final_year_of_manufacture": 2006, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008659", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "Mexico Super", "460 FF", "GC No. 41 392 28", "2001", "2006", "1", "1", "1", "1", "0", "", "", "1", "2", "2", "17.6", "17.6", "", "", "80.1", "70.0", "", "51.1", "", "2", "", "", "101", "1", "1", "100", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.7", "81.6", "", "", "", "", "81.6"]} +{"pcdb_id": 8660, "brand_name": "Ideal", "model_name": "Mexico Super", "model_qualifier": "450 FF", "winter_efficiency_pct": 79.9, "summer_efficiency_pct": 69.8, "comparative_hot_water_efficiency_pct": 51.0, "output_kw_max": 14.7, "final_year_of_manufacture": 2006, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008660", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "Mexico Super", "450 FF", "GC No. 41 392 27", "2001", "2006", "1", "1", "1", "1", "0", "", "", "1", "2", "2", "14.7", "14.7", "", "", "79.9", "69.8", "", "51.0", "", "2", "", "", "101", "1", "1", "100", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.7", "81.4", "", "", "", "", "81.4"]} +{"pcdb_id": 8661, "brand_name": "Ideal", "model_name": "Mexico Super", "model_qualifier": "440 FF", "winter_efficiency_pct": 79.2, "summer_efficiency_pct": 69.1, "comparative_hot_water_efficiency_pct": 50.5, "output_kw_max": 11.7, "final_year_of_manufacture": 2006, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008661", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "Mexico Super", "440 FF", "GC No. 41 392 26", "2001", "2006", "1", "1", "1", "1", "0", "", "", "1", "2", "2", "11.7", "11.7", "", "", "79.2", "69.1", "", "50.5", "", "2", "", "", "101", "1", "1", "100", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.4", "80.3", "", "", "", "", "80.5"]} +{"pcdb_id": 8662, "brand_name": "British / Scottish Gas", "model_name": "RD1 3100", "model_qualifier": "", "winter_efficiency_pct": 78.9, "summer_efficiency_pct": 68.8, "comparative_hot_water_efficiency_pct": 50.3, "output_kw_max": 29.3, "final_year_of_manufacture": 2004, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008662", "000008", "0", "2012/Mar/27 10:12", "Ideal Boilers", "British / Scottish Gas", "RD1 3100", "", "GC No. 41 392 25", "2001", "2004", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "29.3", "29.3", "", "", "78.9", "68.8", "", "50.3", "", "2", "", "", "101", "1", "1", "150", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "80.5", "80.5", "", "", "", "", "80.5"]} +{"pcdb_id": 8663, "brand_name": "British / Scottish Gas", "model_name": "RD1 380", "model_qualifier": "", "winter_efficiency_pct": 79.0, "summer_efficiency_pct": 68.9, "comparative_hot_water_efficiency_pct": 50.3, "output_kw_max": 23.4, "final_year_of_manufacture": 2004, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008663", "000008", "0", "2012/Mar/27 10:12", "Ideal Boilers", "British / Scottish Gas", "RD1 380", "", "GC No. 41 392 24", "2001", "2004", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "23.4", "23.4", "", "", "79.0", "68.9", "", "50.3", "", "2", "", "", "101", "1", "1", "150", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "80.6", "80.5", "", "", "", "", "80.6"]} +{"pcdb_id": 8664, "brand_name": "British / Scottish Gas", "model_name": "RD1 370", "model_qualifier": "", "winter_efficiency_pct": 79.4, "summer_efficiency_pct": 69.3, "comparative_hot_water_efficiency_pct": 50.6, "output_kw_max": 20.5, "final_year_of_manufacture": 2004, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008664", "000008", "0", "2012/Mar/27 10:12", "Ideal Boilers", "British / Scottish Gas", "RD1 370", "", "GC No. 41 392 21", "2001", "2004", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "20.5", "20.5", "", "", "79.4", "69.3", "", "50.6", "", "2", "", "", "101", "1", "1", "150", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.2", "80.8", "", "", "", "", "80.9"]} +{"pcdb_id": 8665, "brand_name": "British / Scottish Gas", "model_name": "RD1 360", "model_qualifier": "", "winter_efficiency_pct": 79.2, "summer_efficiency_pct": 69.1, "comparative_hot_water_efficiency_pct": 50.5, "output_kw_max": 17.6, "final_year_of_manufacture": 2004, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008665", "000008", "0", "2012/Mar/27 10:12", "Ideal Boilers", "British / Scottish Gas", "RD1 360", "", "GC No. 41 392 20", "2001", "2004", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "17.6", "17.6", "", "", "79.2", "69.1", "", "50.5", "", "2", "", "", "101", "1", "1", "150", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "80.8", "80.7", "", "", "", "", "80.7"]} +{"pcdb_id": 8666, "brand_name": "British / Scottish Gas", "model_name": "RD1 350", "model_qualifier": "", "winter_efficiency_pct": 80.7, "summer_efficiency_pct": 70.6, "comparative_hot_water_efficiency_pct": 51.5, "output_kw_max": 14.7, "final_year_of_manufacture": 2004, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008666", "000008", "0", "2012/Mar/27 10:12", "Ideal Boilers", "British / Scottish Gas", "RD1 350", "", "GC No. 41 392 17", "2001", "2004", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "14.7", "14.7", "", "", "80.7", "70.6", "", "51.5", "", "2", "", "", "101", "1", "1", "150", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.3", "82.3", "", "", "", "", "82.3"]} +{"pcdb_id": 8667, "brand_name": "British / Scottish Gas", "model_name": "RD1 340", "model_qualifier": "", "winter_efficiency_pct": 79.5, "summer_efficiency_pct": 69.4, "comparative_hot_water_efficiency_pct": 50.7, "output_kw_max": 11.7, "final_year_of_manufacture": 2004, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008667", "000008", "0", "2012/Mar/27 10:12", "Ideal Boilers", "British / Scottish Gas", "RD1 340", "", "GC No. 41 392 16", "2001", "2004", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "11.7", "11.7", "", "", "79.5", "69.4", "", "50.7", "", "2", "", "", "101", "1", "1", "150", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.0", "81.3", "", "", "", "", "81.2"]} +{"pcdb_id": 8668, "brand_name": "British / Scottish Gas", "model_name": "RD1 330", "model_qualifier": "", "winter_efficiency_pct": 80.4, "summer_efficiency_pct": 70.3, "comparative_hot_water_efficiency_pct": 51.4, "output_kw_max": 8.8, "final_year_of_manufacture": 2004, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008668", "000008", "0", "2012/Mar/27 10:12", "Ideal Boilers", "British / Scottish Gas", "RD1 330", "", "GC No. 41 392 13", "2001", "2004", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "8.8", "8.8", "", "", "80.4", "70.3", "", "51.4", "", "2", "", "", "101", "1", "1", "150", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.9", "82.2", "", "", "", "", "82.1"]} +{"pcdb_id": 8669, "brand_name": "British / Scottish Gas", "model_name": "RD2 4125", "model_qualifier": "", "winter_efficiency_pct": 79.4, "summer_efficiency_pct": 69.3, "comparative_hot_water_efficiency_pct": 50.7, "output_kw_max": 36.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008669", "000008", "0", "2012/Mar/27 10:12", "Ideal Boilers", "British / Scottish Gas", "RD2 4125", "", "GC No. 41 392 73", "2001", "current", "1", "1", "1", "1", "0", "", "", "1", "2", "2", "36.6", "36.6", "", "", "79.4", "69.3", "", "50.7", "", "2", "", "", "101", "1", "1", "150", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "80.9", "81.2", "", "", "", "", "81.1"]} +{"pcdb_id": 8670, "brand_name": "British / Scottish Gas", "model_name": "RD2 4100", "model_qualifier": "", "winter_efficiency_pct": 79.8, "summer_efficiency_pct": 69.7, "comparative_hot_water_efficiency_pct": 50.9, "output_kw_max": 29.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008670", "000008", "0", "2012/Mar/27 10:12", "Ideal Boilers", "British / Scottish Gas", "RD2 4100", "", "GC No. 41 392 72", "2001", "current", "1", "1", "1", "1", "0", "", "", "1", "2", "2", "29.3", "29.3", "", "", "79.8", "69.7", "", "50.9", "", "2", "", "", "101", "1", "1", "150", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.5", "81.3", "", "", "", "", "81.3"]} +{"pcdb_id": 8671, "brand_name": "British / Scottish Gas", "model_name": "RD2 480", "model_qualifier": "", "winter_efficiency_pct": 80.8, "summer_efficiency_pct": 70.7, "comparative_hot_water_efficiency_pct": 51.7, "output_kw_max": 23.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008671", "000008", "0", "2012/Mar/27 10:12", "Ideal Boilers", "British / Scottish Gas", "RD2 480", "", "GC No. 41 392 37", "2001", "current", "1", "1", "1", "1", "0", "", "", "1", "2", "2", "23.4", "23.4", "", "", "80.8", "70.7", "", "51.7", "", "2", "", "", "101", "1", "1", "150", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.4", "82.5", "", "", "", "", "82.5"]} +{"pcdb_id": 8672, "brand_name": "British / Scottish Gas", "model_name": "RD2 470", "model_qualifier": "", "winter_efficiency_pct": 81.4, "summer_efficiency_pct": 71.3, "comparative_hot_water_efficiency_pct": 52.1, "output_kw_max": 20.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008672", "000008", "0", "2012/Mar/27 10:12", "Ideal Boilers", "British / Scottish Gas", "RD2 470", "", "GC No. 41 392 36", "2001", "current", "1", "1", "1", "1", "0", "", "", "1", "2", "2", "20.5", "20.5", "", "", "81.4", "71.3", "", "52.1", "", "2", "", "", "101", "1", "1", "150", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "83.2", "83.2", "", "", "", "", "83.2"]} +{"pcdb_id": 8673, "brand_name": "British / Scottish Gas", "model_name": "RD2 460", "model_qualifier": "", "winter_efficiency_pct": 80.1, "summer_efficiency_pct": 70.0, "comparative_hot_water_efficiency_pct": 51.1, "output_kw_max": 17.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008673", "000008", "0", "2012/Mar/27 10:12", "Ideal Boilers", "British / Scottish Gas", "RD2 460", "", "GC No. 41 392 35", "2001", "current", "1", "1", "1", "1", "0", "", "", "1", "2", "2", "17.6", "17.6", "", "", "80.1", "70.0", "", "51.1", "", "2", "", "", "101", "1", "1", "150", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.7", "81.6", "", "", "", "", "81.6"]} +{"pcdb_id": 8674, "brand_name": "British / Scottish Gas", "model_name": "RD2 450", "model_qualifier": "", "winter_efficiency_pct": 79.9, "summer_efficiency_pct": 69.8, "comparative_hot_water_efficiency_pct": 51.0, "output_kw_max": 14.7, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008674", "000008", "0", "2012/Mar/27 10:12", "Ideal Boilers", "British / Scottish Gas", "RD2 450", "", "GC No. 41 392 34", "2001", "current", "1", "1", "1", "1", "0", "", "", "1", "2", "2", "14.7", "14.7", "", "", "79.9", "69.8", "", "51.0", "", "2", "", "", "101", "1", "1", "150", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.7", "81.4", "", "", "", "", "81.4"]} +{"pcdb_id": 8675, "brand_name": "British / Scottish Gas", "model_name": "RD2 440", "model_qualifier": "", "winter_efficiency_pct": 79.2, "summer_efficiency_pct": 69.1, "comparative_hot_water_efficiency_pct": 50.5, "output_kw_max": 11.7, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008675", "000008", "0", "2012/Mar/27 10:12", "Ideal Boilers", "British / Scottish Gas", "RD2 440", "", "GC No. 41 392 33", "2001", "current", "1", "1", "1", "1", "0", "", "", "1", "2", "2", "11.7", "11.7", "", "", "79.2", "69.1", "", "50.5", "", "2", "", "", "101", "1", "1", "150", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.4", "80.3", "", "", "", "", "80.5"]} +{"pcdb_id": 8676, "brand_name": "Ideal", "model_name": "Classic", "model_qualifier": "RS 360", "winter_efficiency_pct": 79.9, "summer_efficiency_pct": 69.8, "comparative_hot_water_efficiency_pct": 51.0, "output_kw_max": 17.6, "final_year_of_manufacture": 2004, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008676", "000008", "0", "2012/Mar/27 10:12", "Ideal Boilers", "Ideal", "Classic", "RS 360", "GC No. 41 392 12", "2001", "2004", "1", "2", "1", "1", "0", "", "", "1", "2", "1", "17.6", "17.6", "", "", "79.9", "69.8", "", "51.0", "", "2", "", "", "101", "1", "1", "10", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.9", "81.1", "", "", "", "", "81.2"]} +{"pcdb_id": 8677, "brand_name": "Ideal", "model_name": "Classic", "model_qualifier": "RS 350", "winter_efficiency_pct": 81.2, "summer_efficiency_pct": 71.1, "comparative_hot_water_efficiency_pct": 51.9, "output_kw_max": 14.7, "final_year_of_manufacture": 2004, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008677", "000008", "0", "2012/Mar/27 10:12", "Ideal Boilers", "Ideal", "Classic", "RS 350", "GC No. 41 392 11", "2001", "2004", "1", "2", "1", "1", "0", "", "", "1", "2", "1", "14.7", "14.7", "", "", "81.2", "71.1", "", "51.9", "", "2", "", "", "101", "1", "1", "10", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.9", "82.6", "", "", "", "", "82.7"]} +{"pcdb_id": 8678, "brand_name": "Ideal", "model_name": "Classic", "model_qualifier": "RS 340", "winter_efficiency_pct": 79.8, "summer_efficiency_pct": 69.7, "comparative_hot_water_efficiency_pct": 50.9, "output_kw_max": 11.7, "final_year_of_manufacture": 2004, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008678", "000008", "0", "2012/Mar/27 10:12", "Ideal Boilers", "Ideal", "Classic", "RS 340", "GC No. 41 392 10", "2001", "2004", "1", "2", "1", "1", "0", "", "", "1", "2", "1", "11.7", "11.7", "", "", "79.8", "69.7", "", "50.9", "", "2", "", "", "101", "1", "1", "10", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.2", "81.5", "", "", "", "", "81.5"]} +{"pcdb_id": 8679, "brand_name": "Ideal", "model_name": "Classic", "model_qualifier": "RS 330", "winter_efficiency_pct": 79.2, "summer_efficiency_pct": 69.1, "comparative_hot_water_efficiency_pct": 50.5, "output_kw_max": 8.8, "final_year_of_manufacture": 2004, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008679", "000008", "0", "2012/Mar/27 10:12", "Ideal Boilers", "Ideal", "Classic", "RS 330", "GC No. 41 392 09", "2001", "2004", "1", "2", "1", "1", "0", "", "", "1", "2", "1", "8.8", "8.8", "", "", "79.2", "69.1", "", "50.5", "", "2", "", "", "101", "1", "1", "10", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.2", "80.5", "", "", "", "", "80.6"]} +{"pcdb_id": 8680, "brand_name": "Ideal", "model_name": "Mexico Super", "model_qualifier": "CF 4140", "winter_efficiency_pct": 79.5, "summer_efficiency_pct": 69.4, "comparative_hot_water_efficiency_pct": 50.7, "output_kw_max": 41.0, "final_year_of_manufacture": 2006, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008680", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "Mexico Super", "CF 4140", "GC No. 41 392 87", "2001", "2006", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "41", "41.0", "", "", "79.5", "69.4", "", "50.7", "", "2", "", "", "101", "1", "1", "10", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.0", "80.3", "", "", "", "", "80.6"]} +{"pcdb_id": 8681, "brand_name": "Ideal", "model_name": "Mexico Super", "model_qualifier": "CF 4120", "winter_efficiency_pct": 79.9, "summer_efficiency_pct": 69.8, "comparative_hot_water_efficiency_pct": 50.9, "output_kw_max": 35.2, "final_year_of_manufacture": 2006, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008681", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "Mexico Super", "CF 4120", "GC No. 41 392 86", "2001", "2006", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "35.2", "35.2", "", "", "79.9", "69.8", "", "50.9", "", "2", "", "", "101", "1", "1", "10", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.6", "81.3", "", "", "", "", "81.3"]} +{"pcdb_id": 8682, "brand_name": "Ideal", "model_name": "Mexico Super", "model_qualifier": "CF 495", "winter_efficiency_pct": 79.7, "summer_efficiency_pct": 69.6, "comparative_hot_water_efficiency_pct": 50.8, "output_kw_max": 27.8, "final_year_of_manufacture": 2006, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008682", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "Mexico Super", "CF 495", "GC No. 41 392 85", "2001", "2006", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "27.8", "27.8", "", "", "79.7", "69.6", "", "50.8", "", "2", "", "", "101", "1", "1", "10", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.5", "81.1", "", "", "", "", "81.2"]} +{"pcdb_id": 8683, "brand_name": "Ideal", "model_name": "Mexico Super", "model_qualifier": "CF 475", "winter_efficiency_pct": 79.8, "summer_efficiency_pct": 69.7, "comparative_hot_water_efficiency_pct": 50.9, "output_kw_max": 22.0, "final_year_of_manufacture": 2006, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008683", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "Mexico Super", "CF 475", "GC No. 41 392 84", "2001", "2006", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "22", "22.0", "", "", "79.8", "69.7", "", "50.9", "", "2", "", "", "101", "1", "1", "10", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.1", "81.6", "", "", "", "", "81.5"]} +{"pcdb_id": 8684, "brand_name": "Ideal", "model_name": "Mexico Super", "model_qualifier": "CF 465", "winter_efficiency_pct": 80.7, "summer_efficiency_pct": 70.6, "comparative_hot_water_efficiency_pct": 51.5, "output_kw_max": 19.1, "final_year_of_manufacture": 2006, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008684", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "Mexico Super", "CF 465", "GC No. 41 392 83", "2001", "2006", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "19.1", "19.1", "", "", "80.7", "70.6", "", "51.5", "", "2", "", "", "101", "1", "1", "10", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.4", "82.2", "", "", "", "", "82.2"]} +{"pcdb_id": 8685, "brand_name": "Ideal", "model_name": "Mexico Super", "model_qualifier": "CF 455", "winter_efficiency_pct": 79.4, "summer_efficiency_pct": 69.3, "comparative_hot_water_efficiency_pct": 50.6, "output_kw_max": 16.1, "final_year_of_manufacture": 2006, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008685", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "Mexico Super", "CF 455", "GC No. 41 392 82", "2001", "2006", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "16.1", "16.1", "", "", "79.4", "69.3", "", "50.6", "", "2", "", "", "101", "1", "1", "10", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.3", "80.7", "", "", "", "", "80.8"]} +{"pcdb_id": 8686, "brand_name": "Ideal", "model_name": "Mexico Super", "model_qualifier": "CF 445", "winter_efficiency_pct": 79.4, "summer_efficiency_pct": 69.3, "comparative_hot_water_efficiency_pct": 50.6, "output_kw_max": 13.2, "final_year_of_manufacture": 2006, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008686", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "Mexico Super", "CF 445", "GC No. 41 392 81", "2001", "2006", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "13.2", "13.2", "", "", "79.4", "69.3", "", "50.6", "", "2", "", "", "101", "1", "1", "10", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.3", "80.6", "", "", "", "", "80.8"]} +{"pcdb_id": 8687, "brand_name": "Ideal", "model_name": "Mexico Slimline", "model_qualifier": "CF 440", "winter_efficiency_pct": 79.4, "summer_efficiency_pct": 69.3, "comparative_hot_water_efficiency_pct": 50.7, "output_kw_max": 11.7, "final_year_of_manufacture": 2006, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008687", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "Mexico Slimline", "CF 440", "GC No.41 392 89", "2001", "2006", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "11.7", "11.7", "", "", "79.4", "69.3", "", "50.7", "", "2", "", "", "101", "1", "1", "10", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.1", "80.0", "", "", "", "", "80.4"]} +{"pcdb_id": 8688, "brand_name": "Ideal", "model_name": "Mexico Super", "model_qualifier": "RS 4125", "winter_efficiency_pct": 80.3, "summer_efficiency_pct": 70.2, "comparative_hot_water_efficiency_pct": 51.2, "output_kw_max": 36.6, "final_year_of_manufacture": 2006, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008688", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "Mexico Super", "RS 4125", "GC No. 41 392 78", "2001", "2006", "1", "1", "1", "1", "0", "", "", "1", "2", "1", "36.6", "36.6", "", "", "80.3", "70.2", "", "51.2", "", "2", "", "", "101", "1", "1", "10", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.2", "81.5", "", "", "", "", "81.7"]} +{"pcdb_id": 8689, "brand_name": "Ideal", "model_name": "Mexico Super", "model_qualifier": "RS 4100", "winter_efficiency_pct": 79.9, "summer_efficiency_pct": 69.8, "comparative_hot_water_efficiency_pct": 51.0, "output_kw_max": 29.3, "final_year_of_manufacture": 2006, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008689", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "Mexico Super", "RS 4100", "GC No. 41 392 79", "2001", "2006", "1", "1", "1", "1", "0", "", "", "1", "2", "1", "29.3", "29.3", "", "", "79.9", "69.8", "", "51.0", "", "2", "", "", "101", "1", "1", "10", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.8", "81.2", "", "", "", "", "81.3"]} +{"pcdb_id": 8690, "brand_name": "Ideal", "model_name": "Mexico Super", "model_qualifier": "RS 485", "winter_efficiency_pct": 80.0, "summer_efficiency_pct": 69.9, "comparative_hot_water_efficiency_pct": 51.0, "output_kw_max": 24.9, "final_year_of_manufacture": 2006, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008690", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "Mexico Super", "RS 485", "GC No. 41 392 78", "2001", "2006", "1", "1", "1", "1", "0", "", "", "1", "2", "1", "24.9", "24.9", "", "", "80.0", "69.9", "", "51.0", "", "2", "", "", "101", "1", "1", "10", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.8", "81.4", "", "", "", "", "81.4"]} +{"pcdb_id": 8691, "brand_name": "Ideal", "model_name": "Mexico Super", "model_qualifier": "RS 470", "winter_efficiency_pct": 79.9, "summer_efficiency_pct": 69.8, "comparative_hot_water_efficiency_pct": 51.0, "output_kw_max": 20.5, "final_year_of_manufacture": 2006, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008691", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "Mexico Super", "RS 470", "GC No. 41 392 77", "2001", "2006", "1", "1", "1", "1", "0", "", "", "1", "2", "1", "20.5", "20.5", "", "", "79.9", "69.8", "", "51.0", "", "2", "", "", "101", "1", "1", "10", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.9", "81.1", "", "", "", "", "81.2"]} +{"pcdb_id": 8692, "brand_name": "Ideal", "model_name": "Mexico Super", "model_qualifier": "RS 460", "winter_efficiency_pct": 79.9, "summer_efficiency_pct": 69.8, "comparative_hot_water_efficiency_pct": 50.9, "output_kw_max": 17.6, "final_year_of_manufacture": 2006, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008692", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "Mexico Super", "RS 460", "GC No. 41 392 76", "2001", "2006", "1", "1", "1", "1", "0", "", "", "1", "2", "1", "17.6", "17.6", "", "", "79.9", "69.8", "", "50.9", "", "2", "", "", "101", "1", "1", "10", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.1", "81.8", "", "", "", "", "81.7"]} +{"pcdb_id": 8693, "brand_name": "Ideal", "model_name": "Mexico Super", "model_qualifier": "RS 450", "winter_efficiency_pct": 80.0, "summer_efficiency_pct": 69.9, "comparative_hot_water_efficiency_pct": 51.1, "output_kw_max": 14.7, "final_year_of_manufacture": 2006, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008693", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "Mexico Super", "RS 450", "GC No. 41 392 75", "2001", "2006", "1", "1", "1", "1", "0", "", "", "1", "2", "1", "14.7", "14.7", "", "", "80.0", "69.9", "", "51.1", "", "2", "", "", "101", "1", "1", "10", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.1", "81.2", "", "", "", "", "81.4"]} +{"pcdb_id": 8694, "brand_name": "Ideal", "model_name": "Mexico Super", "model_qualifier": "RS 440", "winter_efficiency_pct": 79.5, "summer_efficiency_pct": 69.4, "comparative_hot_water_efficiency_pct": 50.7, "output_kw_max": 11.7, "final_year_of_manufacture": 2006, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008694", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "Mexico Super", "RS 440", "GC No. 41 392 74", "2001", "2006", "1", "1", "1", "1", "0", "", "", "1", "2", "1", "11.7", "11.7", "", "", "79.5", "69.4", "", "50.7", "", "2", "", "", "101", "1", "1", "10", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.4", "80.8", "", "", "", "", "80.9"]} +{"pcdb_id": 8695, "brand_name": "Ideal", "model_name": "Mexico Slimline", "model_qualifier": "RS 445", "winter_efficiency_pct": 79.3, "summer_efficiency_pct": 69.2, "comparative_hot_water_efficiency_pct": 50.5, "output_kw_max": 13.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008695", "000008", "0", "2012/Mar/27 10:12", "Ideal Boilers", "Ideal", "Mexico Slimline", "RS 445", "GC No.41 392 88", "2001", "current", "1", "1", "1", "1", "0", "", "", "1", "2", "1", "13.2", "13.2", "", "", "79.3", "69.2", "", "50.5", "", "2", "", "", "101", "1", "1", "10", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "80.9", "80.8", "", "", "", "", "80.8"]} +{"pcdb_id": 8696, "brand_name": "Vokera", "model_name": "Mynute", "model_qualifier": "28e", "winter_efficiency_pct": 79.1, "summer_efficiency_pct": 68.4, "comparative_hot_water_efficiency_pct": 50.0, "output_kw_max": 28.0, "final_year_of_manufacture": 2010, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008696", "000011", "0", "2012/Mar/27 10:12", "Vokera", "Vokera", "Mynute", "28e", "", "2001", "2010", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "28", "28", "", "", "79.1", "68.4", "", "50.0", "", "2", "", "", "102", "1", "2", "125", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "83.0", "77.3", "", "", "", "", "78.4"]} +{"pcdb_id": 8697, "brand_name": "Vokera", "model_name": "Eclipse ESC", "model_qualifier": "226", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 56.1, "output_kw_max": 26.1, "final_year_of_manufacture": 2010, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008697", "000011", "0", "2010/Oct/21 11:01", "Vokera", "Vokera", "Eclipse ESC", "226", "", "2001", "2010", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "26.1", "26.1", "", "", "88.4", "79.8", "", "56.1", "", "2", "", "", "104", "1", "2", "130", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.5", "97.7", "", "", "", "", "95.9"]} +{"pcdb_id": 8698, "brand_name": "Vokera", "model_name": "Eclipse ESS", "model_qualifier": "226", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 26.1, "final_year_of_manufacture": 2010, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008698", "000011", "0", "2012/Mar/27 10:12", "Vokera", "Vokera", "Eclipse ESS", "226", "", "2001", "2010", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "26.1", "26.1", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "130", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.5", "97.7", "", "", "", "", "95.9"]} +{"pcdb_id": 8699, "brand_name": "Potterton", "model_name": "Powermax HE", "model_qualifier": "85 CPIH", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 81.2, "comparative_hot_water_efficiency_pct": 53.0, "output_kw_max": 24.0, "final_year_of_manufacture": 2010, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008699", "000005", "0", "2024/Jan/31 10:17", "Baxi UK", "Potterton", "Powermax HE", "85 CPIH", "5106346", "2001", "2010", "1", "1", "1", "2", "0", "", "", "2", "2", "2", "24.0", "24.0", "", "", "88.3", "81.2", "", "53.0", "", "2", "", "", "106", "1", "2", "96", "1", "2", "2", "0", "85", "0", "45", "2", "60", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.7", "97.8", "", "", "", "", "95.8"]} +{"pcdb_id": 8700, "brand_name": "Potterton", "model_name": "Powermax HE", "model_qualifier": "115 CPIH", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 81.2, "comparative_hot_water_efficiency_pct": 50.7, "output_kw_max": 24.0, "final_year_of_manufacture": 2010, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008700", "000005", "0", "2024/Jan/31 10:17", "Baxi UK", "Potterton", "Powermax HE", "115 CPIH", "5106350", "2001", "2010", "1", "1", "1", "2", "0", "", "", "2", "2", "2", "24.0", "24.0", "", "", "88.3", "81.2", "", "50.7", "", "2", "", "", "106", "1", "2", "96", "1", "2", "2", "0", "115", "0", "45", "2", "60", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.7", "97.8", "", "", "", "", "95.8"]} +{"pcdb_id": 8701, "brand_name": "Potterton", "model_name": "Powermax HE", "model_qualifier": "150 CPIH", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 81.3, "comparative_hot_water_efficiency_pct": 47.3, "output_kw_max": 24.0, "final_year_of_manufacture": 2010, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008701", "000005", "0", "2024/Jan/31 10:17", "Baxi UK", "Potterton", "Powermax HE", "150 CPIH", "5106354", "2001", "2010", "1", "1", "1", "2", "0", "", "", "2", "2", "2", "24.0", "24.0", "", "", "88.3", "81.3", "", "47.3", "", "2", "", "", "106", "1", "2", "96", "1", "2", "2", "0", "150", "0", "45", "2", "60", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.7", "97.8", "", "", "", "", "95.8"]} +{"pcdb_id": 8702, "brand_name": "Potterton", "model_name": "Powermax HE", "model_qualifier": "85 CP", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 81.2, "comparative_hot_water_efficiency_pct": 53.0, "output_kw_max": 24.0, "final_year_of_manufacture": 2010, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008702", "000005", "0", "2024/Jan/31 10:17", "Baxi UK", "Potterton", "Powermax HE", "85 CP", "5106344", "2001", "2010", "1", "1", "1", "2", "0", "", "", "2", "2", "2", "24.0", "24.0", "", "", "88.3", "81.2", "", "53.0", "", "2", "", "", "106", "1", "2", "96", "1", "2", "2", "0", "85", "0", "45", "2", "60", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.7", "97.8", "", "", "", "", "95.8"]} +{"pcdb_id": 8703, "brand_name": "Potterton", "model_name": "Powermax HE", "model_qualifier": "115 CP", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 81.2, "comparative_hot_water_efficiency_pct": 50.7, "output_kw_max": 24.0, "final_year_of_manufacture": 2010, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008703", "000005", "0", "2024/Jan/31 10:17", "Baxi UK", "Potterton", "Powermax HE", "115 CP", "5106348", "2001", "2010", "1", "1", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "88.3", "81.2", "", "50.7", "", "2", "", "", "106", "1", "2", "96", "1", "2", "2", "0", "115", "0", "45", "2", "60", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.7", "97.8", "", "", "", "", "95.8"]} +{"pcdb_id": 8704, "brand_name": "Potterton", "model_name": "Powermax HE", "model_qualifier": "150 CP", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 81.3, "comparative_hot_water_efficiency_pct": 47.3, "output_kw_max": 24.0, "final_year_of_manufacture": 2010, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008704", "000005", "0", "2024/Jan/31 10:17", "Baxi UK", "Potterton", "Powermax HE", "150 CP", "5106352", "2001", "2010", "1", "1", "1", "2", "0", "", "", "2", "2", "2", "24.0", "24.0", "", "", "88.3", "81.3", "", "47.3", "", "2", "", "", "106", "1", "2", "96", "1", "2", "2", "0", "150", "0", "45", "2", "60", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.7", "97.8", "", "", "", "", "95.8"]} +{"pcdb_id": 8705, "brand_name": "Worcester", "model_name": "25Si - LL", "model_qualifier": "RSF", "winter_efficiency_pct": 82.0, "summer_efficiency_pct": 71.9, "comparative_hot_water_efficiency_pct": 50.5, "output_kw_max": 25.0, "final_year_of_manufacture": 2002, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008705", "000035", "0", "2002/Sep/27 13:17", "Worcester Heat Systems", "Worcester", "25Si - LL", "RSF", "47 311 50", "1999", "2002", "2", "2", "1", "2", "0", "", "", "1", "2", "2", "25", "25", "", "", "82.0", "71.9", "", "50.5", "", "2", "0", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "86.0", "81.6", "", "", "", "", "82.4"]} +{"pcdb_id": 8706, "brand_name": "Worcester", "model_name": "25Si - LL", "model_qualifier": "RSF", "winter_efficiency_pct": 78.9, "summer_efficiency_pct": 68.8, "comparative_hot_water_efficiency_pct": 48.4, "output_kw_max": 25.0, "final_year_of_manufacture": 2002, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008706", "000035", "0", "2002/Sep/27 13:17", "Worcester Heat Systems", "Worcester", "25Si - LL", "RSF", "47 311 49", "1999", "2002", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "25", "25", "", "", "78.9", "68.8", "", "48.4", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "83.3", "77.2", "", "", "", "", "78.4"]} +{"pcdb_id": 8707, "brand_name": "Vokera", "model_name": "Eclipse ESS", "model_qualifier": "216", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 16.0, "final_year_of_manufacture": 2010, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008707", "000011", "0", "2012/Mar/27 10:12", "Vokera", "Vokera", "Eclipse ESS", "216", "", "2001", "2010", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "16.0", "16.0", "", "", "88.2", "79.2", "", "57.8", "", "2", "", "", "102", "1", "2", "130", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "97.3", "", "", "", "", "95.5"]} +{"pcdb_id": 8709, "brand_name": "Worcester", "model_name": "24 CDi - L", "model_qualifier": "OF", "winter_efficiency_pct": 80.5, "summer_efficiency_pct": 70.4, "comparative_hot_water_efficiency_pct": 49.5, "output_kw_max": 24.0, "final_year_of_manufacture": 2005, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008709", "000035", "0", "2020/Sep/02 14:16", "Worcester Heat Systems", "Worcester", "24 CDi - L", "OF", "47 311 33", "1997", "2005", "2", "2", "1", "2", "0", "", "", "1", "1", "1", "24", "24", "", "", "80.5", "70.4", "", "49.5", "", "2", "0", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "83.2", "80.3", "", "", "", "", "80.9"]} +{"pcdb_id": 8710, "brand_name": "Worcester", "model_name": "24 CDi - L", "model_qualifier": "OF", "winter_efficiency_pct": 79.0, "summer_efficiency_pct": 68.9, "comparative_hot_water_efficiency_pct": 48.4, "output_kw_max": 24.0, "final_year_of_manufacture": 2005, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008710", "000035", "0", "2020/Sep/02 14:16", "Worcester Heat Systems", "Worcester", "24 CDi - L", "OF", "47 311 32", "1997", "2005", "1", "2", "1", "2", "0", "", "", "1", "1", "1", "24", "24", "", "", "79.0", "68.9", "", "48.4", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.3", "79.1", "", "", "", "", "79.5"]} +{"pcdb_id": 8711, "brand_name": "Ferroli", "model_name": "Sigma 20-40", "model_qualifier": "", "winter_efficiency_pct": 79.1, "summer_efficiency_pct": 69.0, "comparative_hot_water_efficiency_pct": 50.4, "output_kw_max": 11.7, "final_year_of_manufacture": 2005, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008711", "000097", "0", "2012/Mar/27 10:12", "Ferroli SpA", "Ferroli", "Sigma 20-40", "", "", "2001", "2005", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "5.5", "11.7", "", "", "79.1", "69.0", "", "50.4", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.9", "79.6", "", "", "", "", "80.0"]} +{"pcdb_id": 8712, "brand_name": "Ferroli", "model_name": "Sigma", "model_qualifier": "40-60", "winter_efficiency_pct": 79.0, "summer_efficiency_pct": 68.9, "comparative_hot_water_efficiency_pct": 50.4, "output_kw_max": 17.6, "final_year_of_manufacture": 2005, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008712", "000097", "0", "2012/Mar/27 10:12", "Ferroli SpA", "Ferroli", "Sigma", "40-60", "", "2001", "2005", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "11.4", "17.6", "", "", "79.0", "68.9", "", "50.4", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.2", "80.1", "", "", "", "", "80.3"]} +{"pcdb_id": 8713, "brand_name": "Ferroli", "model_name": "Sigma 60-100", "model_qualifier": "", "winter_efficiency_pct": 79.2, "summer_efficiency_pct": 69.1, "comparative_hot_water_efficiency_pct": 50.5, "output_kw_max": 29.3, "final_year_of_manufacture": 2005, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008713", "000097", "0", "2012/Mar/27 10:12", "Ferroli SpA", "Ferroli", "Sigma 60-100", "", "", "2001", "2005", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "17.9", "29.3", "", "", "79.2", "69.1", "", "50.5", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.1", "79.6", "", "", "", "", "80.0"]} +{"pcdb_id": 8714, "brand_name": "Ferroli", "model_name": "Tempra 12", "model_qualifier": "", "winter_efficiency_pct": 79.1, "summer_efficiency_pct": 68.4, "comparative_hot_water_efficiency_pct": 49.9, "output_kw_max": 12.0, "final_year_of_manufacture": 2006, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008714", "000097", "0", "2012/Mar/27 10:12", "Ferroli SpA", "Ferroli", "Tempra 12", "", "", "2001", "2006", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "12", "12", "", "", "79.1", "68.4", "", "49.9", "", "2", "", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.5", "78.7", "", "", "", "", "79.2"]} +{"pcdb_id": 8715, "brand_name": "Ferroli", "model_name": "Tempra 18", "model_qualifier": "", "winter_efficiency_pct": 79.1, "summer_efficiency_pct": 68.4, "comparative_hot_water_efficiency_pct": 50.0, "output_kw_max": 18.0, "final_year_of_manufacture": 2006, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008715", "000097", "0", "2012/Mar/27 10:12", "Ferroli SpA", "Ferroli", "Tempra 18", "", "", "2001", "2006", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "18", "18", "", "", "79.1", "68.4", "", "50.0", "", "2", "", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.5", "78.7", "", "", "", "", "79.3"]} +{"pcdb_id": 8716, "brand_name": "Ferroli", "model_name": "Tempra 24", "model_qualifier": "", "winter_efficiency_pct": 79.0, "summer_efficiency_pct": 68.3, "comparative_hot_water_efficiency_pct": 49.9, "output_kw_max": 23.3, "final_year_of_manufacture": 2006, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008716", "000097", "0", "2012/Mar/27 10:12", "Ferroli SpA", "Ferroli", "Tempra 24", "", "", "2001", "2006", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "23.3", "23.3", "", "", "79.0", "68.3", "", "49.9", "", "2", "", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.4", "78.7", "", "", "", "", "79.2"]} +{"pcdb_id": 8717, "brand_name": "Ferroli", "model_name": "Tempra 30", "model_qualifier": "", "winter_efficiency_pct": 79.1, "summer_efficiency_pct": 68.4, "comparative_hot_water_efficiency_pct": 50.0, "output_kw_max": 30.0, "final_year_of_manufacture": 2006, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008717", "000097", "0", "2012/Mar/27 10:12", "Ferroli SpA", "Ferroli", "Tempra 30", "", "", "2001", "2006", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "30", "30", "", "", "79.1", "68.4", "", "50.0", "", "2", "", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.5", "78.7", "", "", "", "", "79.2"]} +{"pcdb_id": 8722, "brand_name": "Sime", "model_name": "Estelle 3", "model_qualifier": "", "winter_efficiency_pct": 84.5, "summer_efficiency_pct": 72.8, "comparative_hot_water_efficiency_pct": 53.2, "output_kw_max": 23.5, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008722", "000213", "0", "2018/Feb/26 15:51", "Fonderie Sime S.p.A.", "Sime", "Estelle 3", "", "", "2000", "2018", "4", "1", "1", "1", "0", "", "", "1", "1", "1", "18.9", "23.5", "", "", "84.5", "72.8", "", "53.2", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "84.0", "85.0", "", "", "", "", "84.8"]} +{"pcdb_id": 8723, "brand_name": "Sime", "model_name": "Estelle 4", "model_qualifier": "", "winter_efficiency_pct": 84.7, "summer_efficiency_pct": 73.0, "comparative_hot_water_efficiency_pct": 53.3, "output_kw_max": 31.3, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008723", "000213", "0", "2018/Feb/26 16:49", "Fonderie Sime S.p.A.", "Sime", "Estelle 4", "", "", "2000", "2018", "4", "1", "1", "1", "0", "", "", "1", "1", "1", "24.5", "31.3", "", "", "84.7", "73.0", "", "53.3", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "84.3", "85.1", "", "", "", "", "84.9"]} +{"pcdb_id": 8724, "brand_name": "Sime", "model_name": "Estelle 5", "model_qualifier": "", "winter_efficiency_pct": 84.9, "summer_efficiency_pct": 73.2, "comparative_hot_water_efficiency_pct": 53.5, "output_kw_max": 40.0, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008724", "000213", "0", "2018/Feb/26 16:50", "Fonderie Sime S.p.A.", "Sime", "Estelle 5", "", "", "2000", "2018", "4", "1", "1", "1", "0", "", "", "1", "1", "1", "32.5", "40.0", "", "", "84.9", "73.2", "", "53.5", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "84.6", "85.2", "", "", "", "", "85.1"]} +{"pcdb_id": 8725, "brand_name": "Sime", "model_name": "Estelle 6", "model_qualifier": "", "winter_efficiency_pct": 85.0, "summer_efficiency_pct": 73.3, "comparative_hot_water_efficiency_pct": 53.6, "output_kw_max": 48.1, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008725", "000213", "0", "2018/Feb/26 16:50", "Fonderie Sime S.p.A.", "Sime", "Estelle 6", "", "", "2000", "2018", "4", "1", "1", "1", "0", "", "", "1", "1", "1", "41.7", "48.1", "", "", "85.0", "73.3", "", "53.6", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "84.8", "85.3", "", "", "", "", "85.2"]} +{"pcdb_id": 8726, "brand_name": "Sime", "model_name": "Estelle 7", "model_qualifier": "", "winter_efficiency_pct": 85.2, "summer_efficiency_pct": 73.5, "comparative_hot_water_efficiency_pct": 53.7, "output_kw_max": 57.5, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008726", "000213", "0", "2018/Feb/26 16:51", "Fonderie Sime S.p.A.", "Sime", "Estelle 7", "", "", "2000", "2018", "4", "1", "1", "1", "0", "", "", "1", "1", "1", "49.9", "57.5", "", "", "85.2", "73.5", "", "53.7", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.1", "85.4", "", "", "", "", "85.3"]} +{"pcdb_id": 8730, "brand_name": "Sime", "model_name": "Rondo 3", "model_qualifier": "", "winter_efficiency_pct": 84.5, "summer_efficiency_pct": 72.8, "comparative_hot_water_efficiency_pct": 53.2, "output_kw_max": 23.5, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008730", "000213", "0", "2018/Feb/26 16:30", "Fonderie Sime S.p.A.", "Sime", "Rondo 3", "", "", "2000", "2018", "4", "1", "1", "1", "0", "", "", "1", "1", "1", "18.9", "23.5", "", "", "84.5", "72.8", "", "53.2", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "84.0", "85.0", "", "", "", "", "84.8"]} +{"pcdb_id": 8731, "brand_name": "Sime", "model_name": "Rondo 4", "model_qualifier": "", "winter_efficiency_pct": 84.7, "summer_efficiency_pct": 73.0, "comparative_hot_water_efficiency_pct": 53.3, "output_kw_max": 31.3, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008731", "000213", "0", "2018/Feb/26 16:29", "Fonderie Sime S.p.A.", "Sime", "Rondo 4", "", "", "2000", "2018", "4", "1", "1", "1", "0", "", "", "1", "1", "1", "24.5", "31.3", "", "", "84.7", "73.0", "", "53.3", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "84.3", "85.1", "", "", "", "", "84.9"]} +{"pcdb_id": 8732, "brand_name": "Sime", "model_name": "Rondo 5", "model_qualifier": "", "winter_efficiency_pct": 84.9, "summer_efficiency_pct": 73.2, "comparative_hot_water_efficiency_pct": 53.5, "output_kw_max": 40.0, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008732", "000213", "0", "2018/Feb/26 16:29", "Fonderie Sime S.p.A.", "Sime", "Rondo 5", "", "", "2000", "2018", "4", "1", "1", "1", "0", "", "", "1", "1", "1", "32.5", "40.0", "", "", "84.9", "73.2", "", "53.5", "", "2", "", "", "201", "1", "0", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0000", "", "", "", "", "", "", "", "", "84.6", "85.2", "", "", "", "", "85.1"]} +{"pcdb_id": 8733, "brand_name": "Sime", "model_name": "Rondo 6", "model_qualifier": "", "winter_efficiency_pct": 85.0, "summer_efficiency_pct": 73.3, "comparative_hot_water_efficiency_pct": 53.6, "output_kw_max": 48.1, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008733", "000213", "0", "2018/Feb/26 16:29", "Fonderie Sime S.p.A.", "Sime", "Rondo 6", "", "", "2000", "2018", "4", "1", "1", "1", "0", "", "", "1", "1", "1", "41.7", "48.1", "", "", "85.0", "73.3", "", "53.6", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "84.8", "85.3", "", "", "", "", "85.2"]} +{"pcdb_id": 8734, "brand_name": "Sime", "model_name": "Rondo 7", "model_qualifier": "", "winter_efficiency_pct": 85.2, "summer_efficiency_pct": 73.5, "comparative_hot_water_efficiency_pct": 53.7, "output_kw_max": 57.5, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008734", "000213", "0", "2018/Feb/26 16:28", "Fonderie Sime S.p.A.", "Sime", "Rondo 7", "", "", "2000", "2018", "4", "1", "1", "1", "0", "", "", "1", "1", "1", "49.9", "57.5", "", "", "85.2", "73.5", "", "53.7", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.1", "85.4", "", "", "", "", "85.3"]} +{"pcdb_id": 8737, "brand_name": "Sime", "model_name": "RX 55 CE iono", "model_qualifier": "", "winter_efficiency_pct": 81.2, "summer_efficiency_pct": 71.1, "comparative_hot_water_efficiency_pct": 51.9, "output_kw_max": 60.7, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008737", "000213", "0", "2018/Mar/05 15:03", "Fonderie Sime S.p.A.", "Sime", "RX 55 CE iono", "", "", "1998", "2018", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "60.7", "60.7", "", "", "81.2", "71.1", "", "51.9", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "83.0", "82.7", "", "", "", "", "82.8"]} +{"pcdb_id": 8738, "brand_name": "Sime", "model_name": "RX 48 CE iono", "model_qualifier": "", "winter_efficiency_pct": 81.2, "summer_efficiency_pct": 71.1, "comparative_hot_water_efficiency_pct": 51.9, "output_kw_max": 48.8, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008738", "000213", "0", "2018/Mar/05 15:02", "Fonderie Sime S.p.A.", "Sime", "RX 48 CE iono", "", "", "1998", "2018", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "48.8", "48.8", "", "", "81.2", "71.1", "", "51.9", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "83.0", "82.7", "", "", "", "", "82.8"]} +{"pcdb_id": 8739, "brand_name": "Sime", "model_name": "RX 37 CE iono", "model_qualifier": "", "winter_efficiency_pct": 81.6, "summer_efficiency_pct": 71.5, "comparative_hot_water_efficiency_pct": 52.2, "output_kw_max": 39.1, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008739", "000213", "0", "2018/Mar/05 15:01", "Fonderie Sime S.p.A.", "Sime", "RX 37 CE iono", "", "", "1998", "2018", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "39.1", "39.1", "", "", "81.6", "71.5", "", "52.2", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "80.7", "85.7", "", "", "", "", "84.7"]} +{"pcdb_id": 8755, "brand_name": "Sime", "model_name": "1 R 6 Freestanding", "model_qualifier": "", "winter_efficiency_pct": 83.4, "summer_efficiency_pct": 71.7, "comparative_hot_water_efficiency_pct": 52.4, "output_kw_max": 64.8, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008755", "000213", "0", "2018/Feb/26 15:42", "Fonderie Sime S.p.A.", "Sime", "1 R 6 Freestanding", "", "", "1998", "2018", "4", "1", "1", "1", "0", "", "", "1", "1", "1", "64.8", "64.8", "", "", "83.4", "71.7", "", "52.4", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.8", "84.0", "", "", "", "", "83.7"]} +{"pcdb_id": 8756, "brand_name": "Sime", "model_name": "1 R 5 Freestanding", "model_qualifier": "", "winter_efficiency_pct": 83.1, "summer_efficiency_pct": 71.4, "comparative_hot_water_efficiency_pct": 52.1, "output_kw_max": 52.0, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008756", "000213", "0", "2018/Feb/26 15:40", "Fonderie Sime S.p.A.", "Sime", "1 R 5 Freestanding", "", "", "1998", "2018", "4", "1", "1", "1", "0", "", "", "1", "1", "1", "52", "52", "", "", "83.1", "71.4", "", "52.1", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.5", "83.7", "", "", "", "", "83.4"]} +{"pcdb_id": 8757, "brand_name": "Sime", "model_name": "1 R 4 Freestanding", "model_qualifier": "", "winter_efficiency_pct": 82.7, "summer_efficiency_pct": 71.0, "comparative_hot_water_efficiency_pct": 51.9, "output_kw_max": 39.2, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008757", "000213", "0", "2018/Feb/26 15:38", "Fonderie Sime S.p.A.", "Sime", "1 R 4 Freestanding", "", "", "1998", "2018", "4", "1", "1", "1", "0", "", "", "1", "1", "1", "39.2", "39.2", "", "", "82.7", "71.0", "", "51.9", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.2", "83.3", "", "", "", "", "83.1"]} +{"pcdb_id": 8758, "brand_name": "Worcester", "model_name": "Danesmoor Wall Mounted", "model_qualifier": "12/19 - R00 - GB - L", "winter_efficiency_pct": 85.5, "summer_efficiency_pct": 73.8, "comparative_hot_water_efficiency_pct": 53.9, "output_kw_max": 19.0, "final_year_of_manufacture": 2008, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008758", "000035", "0", "2020/Sep/02 14:16", "Worcester Heat Systems", "Worcester", "Danesmoor Wall Mounted", "12/19 - R00 - GB - L", "C16424/1", "2001", "2008", "4", "2", "2", "1", "0", "", "", "1", "2", "2", "12", "19", "", "", "85.5", "73.8", "", "53.9", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.5", "85.6", "", "", "", "", "85.6"]} +{"pcdb_id": 8759, "brand_name": "Worcester", "model_name": "Danesmoor Utility", "model_qualifier": "32/50 - 000 - GB - Utility - L", "winter_efficiency_pct": 85.4, "summer_efficiency_pct": 73.7, "comparative_hot_water_efficiency_pct": 53.8, "output_kw_max": 50.0, "final_year_of_manufacture": 2008, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008759", "000035", "0", "2020/Sep/02 14:16", "Worcester Heat Systems", "Worcester", "Danesmoor Utility", "32/50 - 000 - GB - Utility - L", "C16396/1", "2001", "2008", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "32", "50", "", "", "85.4", "73.7", "", "53.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.6", "85.2", "", "", "", "", "85.3"]} +{"pcdb_id": 8760, "brand_name": "Worcester", "model_name": "Danesmoor", "model_qualifier": "32/50 - 000 -GB - L", "winter_efficiency_pct": 85.4, "summer_efficiency_pct": 73.7, "comparative_hot_water_efficiency_pct": 53.8, "output_kw_max": 50.0, "final_year_of_manufacture": 2008, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008760", "000035", "0", "2020/Sep/02 14:17", "Worcester Heat Systems", "Worcester", "Danesmoor", "32/50 - 000 -GB - L", "C16396/1", "2001", "2008", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "32", "50", "", "", "85.4", "73.7", "", "53.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.6", "85.2", "", "", "", "", "85.3"]} +{"pcdb_id": 8761, "brand_name": "Worcester", "model_name": "Danesmoor Utility", "model_qualifier": "50/70 - 000 - GB - Utility - L", "winter_efficiency_pct": 85.2, "summer_efficiency_pct": 73.5, "comparative_hot_water_efficiency_pct": 53.7, "output_kw_max": 70.0, "final_year_of_manufacture": 2008, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008761", "000035", "0", "2020/Sep/02 14:17", "Worcester Heat Systems", "Worcester", "Danesmoor Utility", "50/70 - 000 - GB - Utility - L", "C16414/1", "2001", "2008", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "50", "70", "", "", "85.2", "73.5", "", "53.7", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.4", "85.0", "", "", "", "", "85.1"]} +{"pcdb_id": 8762, "brand_name": "Worcester", "model_name": "Danesmoor", "model_qualifier": "50/70 - 000 - GB - L", "winter_efficiency_pct": 85.2, "summer_efficiency_pct": 73.5, "comparative_hot_water_efficiency_pct": 53.7, "output_kw_max": 70.0, "final_year_of_manufacture": 2008, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008762", "000035", "0", "2020/Sep/02 14:17", "Worcester Heat Systems", "Worcester", "Danesmoor", "50/70 - 000 - GB - L", "C16414/1", "2001", "2008", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "50", "70", "", "", "85.2", "73.5", "", "53.7", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.4", "85.0", "", "", "", "", "85.1"]} +{"pcdb_id": 8763, "brand_name": "Glow-worm", "model_name": "23c", "model_qualifier": "", "winter_efficiency_pct": 80.8, "summer_efficiency_pct": 70.7, "comparative_hot_water_efficiency_pct": 49.7, "output_kw_max": 23.6, "final_year_of_manufacture": 2003, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008763", "000207", "0", "2006/Jan/17 12:55", "Hepworth Heating", "Glow-worm", "23c", "", "GC 47-047-18", "2000", "2003", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "23.6", "23.6", "", "", "80.8", "70.7", "", "49.7", "", "2", "", "", "104", "1", "2", "160", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.8", "81.3", "", "", "", "", "81.6"]} +{"pcdb_id": 8764, "brand_name": "Protherm", "model_name": "100EC", "model_qualifier": "", "winter_efficiency_pct": 80.2, "summer_efficiency_pct": 70.1, "comparative_hot_water_efficiency_pct": 49.3, "output_kw_max": 27.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008764", "000020", "0", "2006/Jan/17 12:31", "Hepworth Heating", "Protherm", "100EC", "", "GC 47-920-33", "2000", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "27.4", "27.4", "", "", "80.2", "70.1", "", "49.3", "", "2", "", "", "104", "1", "2", "160", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.3", "80.5", "", "", "", "", "80.9"]} +{"pcdb_id": 8765, "brand_name": "Jaguar", "model_name": "28", "model_qualifier": "", "winter_efficiency_pct": 80.2, "summer_efficiency_pct": 70.1, "comparative_hot_water_efficiency_pct": 49.3, "output_kw_max": 27.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008765", "000020", "0", "2006/Jan/17 12:31", "Hepworth Heating", "Jaguar", "28", "", "GC 47-047-17", "2000", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "27.4", "27.4", "", "", "80.2", "70.1", "", "49.3", "", "2", "", "", "104", "1", "2", "145", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.3", "80.5", "", "", "", "", "80.9"]} +{"pcdb_id": 8766, "brand_name": "Protherm", "model_name": "80 E", "model_qualifier": "", "winter_efficiency_pct": 79.6, "summer_efficiency_pct": 69.5, "comparative_hot_water_efficiency_pct": 48.9, "output_kw_max": 23.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008766", "000020", "0", "2006/Jan/17 12:31", "Hepworth Heating", "Protherm", "80 E", "", "GC 47-920-17", "2000", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "23.0", "23.0", "", "", "79.6", "69.5", "", "48.9", "", "2", "", "", "104", "1", "2", "135", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.5", "80.1", "", "", "", "", "80.4"]} +{"pcdb_id": 8767, "brand_name": "Protherm", "model_name": "80 EC", "model_qualifier": "", "winter_efficiency_pct": 79.6, "summer_efficiency_pct": 69.5, "comparative_hot_water_efficiency_pct": 48.9, "output_kw_max": 23.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008767", "000020", "0", "2006/Jan/17 12:31", "Hepworth Heating", "Protherm", "80 EC", "", "GC 47-920-34", "2000", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "23.0", "23.0", "", "", "79.6", "69.5", "", "48.9", "", "2", "", "", "104", "1", "2", "135", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.5", "80.1", "", "", "", "", "80.4"]} +{"pcdb_id": 8768, "brand_name": "Jaguar", "model_name": "23", "model_qualifier": "", "winter_efficiency_pct": 79.6, "summer_efficiency_pct": 69.5, "comparative_hot_water_efficiency_pct": 48.9, "output_kw_max": 23.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008768", "000020", "0", "2006/Jan/17 12:31", "Hepworth Heating", "Jaguar", "23", "", "GC 47-047-16", "2000", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "23.0", "23.0", "", "", "79.6", "69.5", "", "48.9", "", "2", "", "", "104", "1", "2", "135", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.5", "80.1", "", "", "", "", "80.4"]} +{"pcdb_id": 8769, "brand_name": "Potterton", "model_name": "Statesman", "model_qualifier": "45/50L", "winter_efficiency_pct": 86.2, "summer_efficiency_pct": 74.5, "comparative_hot_water_efficiency_pct": 54.4, "output_kw_max": 15.0, "final_year_of_manufacture": 2007, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008769", "000005", "0", "2012/Mar/27 10:12", "Baxi Potterton", "Potterton", "Statesman", "45/50L", "LVR", "2001", "2007", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "13", "15", "", "", "86.2", "74.5", "", "54.4", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.3", "86.1", "", "", "", "", "86.3"]} +{"pcdb_id": 8770, "brand_name": "Potterton", "model_name": "Statesman", "model_qualifier": "50/70L", "winter_efficiency_pct": 86.5, "summer_efficiency_pct": 74.8, "comparative_hot_water_efficiency_pct": 54.6, "output_kw_max": 20.0, "final_year_of_manufacture": 2007, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008770", "000005", "0", "2012/Mar/27 10:12", "Baxi Potterton", "Potterton", "Statesman", "50/70L", "LVS", "2001", "2007", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "15", "20", "", "", "86.5", "74.8", "", "54.6", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.1", "86.9", "", "", "", "", "86.7"]} +{"pcdb_id": 8771, "brand_name": "Potterton", "model_name": "Statesman", "model_qualifier": "70/90L", "winter_efficiency_pct": 86.0, "summer_efficiency_pct": 74.3, "comparative_hot_water_efficiency_pct": 54.3, "output_kw_max": 26.0, "final_year_of_manufacture": 2007, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008771", "000005", "0", "2012/Mar/27 10:12", "Baxi Potterton", "Potterton", "Statesman", "70/90L", "LVT", "2001", "2007", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "20", "26", "", "", "86.0", "74.3", "", "54.3", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.3", "86.8", "", "", "", "", "86.5"]} +{"pcdb_id": 8772, "brand_name": "Potterton", "model_name": "Statesman", "model_qualifier": "90/110L", "winter_efficiency_pct": 85.8, "summer_efficiency_pct": 74.1, "comparative_hot_water_efficiency_pct": 54.1, "output_kw_max": 32.0, "final_year_of_manufacture": 2007, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008772", "000005", "0", "2012/Mar/27 10:12", "Baxi Potterton", "Potterton", "Statesman", "90/110L", "LV V", "2001", "2007", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "26", "32", "", "", "85.8", "74.1", "", "54.1", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.1", "86.5", "", "", "", "", "86.2"]} +{"pcdb_id": 8773, "brand_name": "Potterton", "model_name": "Statesman Flowsure Plus", "model_qualifier": "70/90L", "winter_efficiency_pct": 83.9, "summer_efficiency_pct": 75.8, "comparative_hot_water_efficiency_pct": 34.0, "output_kw_max": 26.0, "final_year_of_manufacture": 2007, "subsidiary_type": 0, "store_type": 1, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008773", "000005", "0", "2024/Jan/31 10:17", "Baxi Potterton", "Potterton", "Statesman Flowsure Plus", "70/90L", "LWE", "2001", "2007", "4", "1", "1", "2", "0", "", "", "1", "1", "2", "20", "26", "", "", "83.9", "75.8", "", "34.0", "", "2", "", "", "203", "1", "1", "", "", "1", "2", "0", "40", "0", "13", "6", "75", ".45", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "84.4", "86.6", "", "", "", "", "86.2"]} +{"pcdb_id": 8774, "brand_name": "Potterton", "model_name": "Statesman Flowsure", "model_qualifier": "70/90L", "winter_efficiency_pct": 83.9, "summer_efficiency_pct": 74.4, "comparative_hot_water_efficiency_pct": 52.3, "output_kw_max": 26.0, "final_year_of_manufacture": 2007, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008774", "000005", "0", "2010/Nov/19 09:22", "Baxi Potterton", "Potterton", "Statesman Flowsure", "70/90L", "LWD", "2001", "2007", "4", "1", "1", "2", "0", "", "", "1", "1", "2", "20", "26", "", "", "83.9", "74.4", "", "52.3", "", "2", "", "", "202", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "84.9", "86.5", "", "", "", "", "86.2"]} +{"pcdb_id": 8775, "brand_name": "Potterton", "model_name": "Statesman System", "model_qualifier": "70/90L", "winter_efficiency_pct": 86.0, "summer_efficiency_pct": 74.3, "comparative_hot_water_efficiency_pct": 54.3, "output_kw_max": 26.0, "final_year_of_manufacture": 2007, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008775", "000005", "0", "2012/Mar/27 10:12", "Baxi Potterton", "Potterton", "Statesman System", "70/90L", "LWC", "2001", "2007", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "20", "26", "", "", "86.0", "74.3", "", "54.3", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.0", "87.0", "", "", "", "", "86.6"]} +{"pcdb_id": 8776, "brand_name": "Potterton", "model_name": "Statesman Utility", "model_qualifier": "110/130L", "winter_efficiency_pct": 85.4, "summer_efficiency_pct": 73.7, "comparative_hot_water_efficiency_pct": 53.8, "output_kw_max": 38.0, "final_year_of_manufacture": 2007, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008776", "000005", "0", "2012/Mar/27 10:12", "Baxi Potterton", "Potterton", "Statesman Utility", "110/130L", "LWA", "2001", "2007", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "32", "38", "", "", "85.4", "73.7", "", "53.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.0", "85.7", "", "", "", "", "85.6"]} +{"pcdb_id": 8777, "brand_name": "Potterton", "model_name": "Statesman Utility", "model_qualifier": "130/150L", "winter_efficiency_pct": 86.4, "summer_efficiency_pct": 74.7, "comparative_hot_water_efficiency_pct": 54.6, "output_kw_max": 44.0, "final_year_of_manufacture": 2007, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008777", "000005", "0", "2012/Mar/27 10:12", "Baxi Potterton", "Potterton", "Statesman Utility", "130/150L", "LWB", "2001", "2007", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "38", "44", "", "", "86.4", "74.7", "", "54.6", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.1", "86.8", "", "", "", "", "86.6"]} +{"pcdb_id": 8779, "brand_name": "Potterton", "model_name": "Statesman Utility", "model_qualifier": "50/70L", "winter_efficiency_pct": 86.5, "summer_efficiency_pct": 74.8, "comparative_hot_water_efficiency_pct": 54.6, "output_kw_max": 20.0, "final_year_of_manufacture": 2007, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008779", "000005", "0", "2012/Mar/27 10:12", "Baxi Potterton", "Potterton", "Statesman Utility", "50/70L", "LV W", "2001", "2007", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "15", "20", "", "", "86.5", "74.8", "", "54.6", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.1", "86.9", "", "", "", "", "86.7"]} +{"pcdb_id": 8780, "brand_name": "Potterton", "model_name": "Statesman Utility", "model_qualifier": "70/90L", "winter_efficiency_pct": 86.0, "summer_efficiency_pct": 74.3, "comparative_hot_water_efficiency_pct": 54.3, "output_kw_max": 26.0, "final_year_of_manufacture": 2007, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008780", "000005", "0", "2012/Mar/27 10:12", "Baxi Potterton", "Potterton", "Statesman Utility", "70/90L", "LVX", "2001", "2007", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "20", "26", "", "", "86.0", "74.3", "", "54.3", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.3", "86.8", "", "", "", "", "86.5"]} +{"pcdb_id": 8781, "brand_name": "Potterton", "model_name": "Statesman Utility", "model_qualifier": "90/110L", "winter_efficiency_pct": 85.8, "summer_efficiency_pct": 74.1, "comparative_hot_water_efficiency_pct": 54.1, "output_kw_max": 32.0, "final_year_of_manufacture": 2007, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008781", "000005", "0", "2012/Mar/27 10:12", "Baxi Potterton", "Potterton", "Statesman Utility", "90/110L", "LVY", "2001", "2007", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "26", "32", "", "", "85.8", "74.1", "", "54.1", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.1", "86.5", "", "", "", "", "86.2"]} +{"pcdb_id": 8782, "brand_name": "Protherm", "model_name": "Protherm 60-80 CI", "model_qualifier": "", "winter_efficiency_pct": 79.2, "summer_efficiency_pct": 69.1, "comparative_hot_water_efficiency_pct": 50.5, "output_kw_max": 23.45, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008782", "000020", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Protherm", "Protherm 60-80 CI", "", "41 047 66", "2001", "current", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "17.58", "23.45", "", "", "79.2", "69.1", "", "50.5", "", "2", "", "", "101", "1", "1", "71", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "80.6", "81.0", "", "", "", "", "80.9"]} +{"pcdb_id": 8783, "brand_name": "Protherm", "model_name": "Protherm 40-50 CI", "model_qualifier": "", "winter_efficiency_pct": 79.8, "summer_efficiency_pct": 69.7, "comparative_hot_water_efficiency_pct": 50.9, "output_kw_max": 14.65, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008783", "000020", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Protherm", "Protherm 40-50 CI", "", "41 047 53", "2001", "current", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "11.72", "14.65", "", "", "79.8", "69.7", "", "50.9", "", "2", "", "", "101", "1", "1", "56", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.1", "80.6", "", "", "", "", "80.9"]} +{"pcdb_id": 8784, "brand_name": "Ikon", "model_name": "40-50 CI", "model_qualifier": "", "winter_efficiency_pct": 79.8, "summer_efficiency_pct": 69.7, "comparative_hot_water_efficiency_pct": 50.9, "output_kw_max": 14.65, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008784", "000020", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Ikon", "40-50 CI", "", "41 047 67", "2001", "current", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "11.72", "14.65", "", "", "79.8", "69.7", "", "50.9", "", "2", "", "", "101", "1", "1", "56", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.1", "80.6", "", "", "", "", "80.9"]} +{"pcdb_id": 8785, "brand_name": "Ikon", "model_name": "60-80 CI", "model_qualifier": "", "winter_efficiency_pct": 79.2, "summer_efficiency_pct": 69.1, "comparative_hot_water_efficiency_pct": 50.5, "output_kw_max": 23.45, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008785", "000020", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Ikon", "60-80 CI", "", "41 047 68", "2001", "current", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "17.58", "23.45", "", "", "79.2", "69.1", "", "50.5", "", "2", "", "", "101", "1", "1", "71", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "80.6", "81.0", "", "", "", "", "80.9"]} +{"pcdb_id": 8786, "brand_name": "Glow-worm", "model_name": "Micron 30 FF", "model_qualifier": "", "winter_efficiency_pct": 79.2, "summer_efficiency_pct": 69.1, "comparative_hot_water_efficiency_pct": 50.5, "output_kw_max": 8.79, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008786", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Micron 30 FF", "", "41 047 46", "2001", "current", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "8.79", "8.79", "", "", "79.2", "69.1", "", "50.5", "", "2", "", "", "101", "1", "1", "66", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.5", "80.0", "", "", "", "", "80.3"]} +{"pcdb_id": 8787, "brand_name": "Glow-worm", "model_name": "Micron 40 FF", "model_qualifier": "", "winter_efficiency_pct": 79.6, "summer_efficiency_pct": 69.5, "comparative_hot_water_efficiency_pct": 50.8, "output_kw_max": 11.72, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008787", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Micron 40 FF", "", "41 047 47", "2001", "current", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "8.8", "11.72", "", "", "79.6", "69.5", "", "50.8", "", "2", "", "", "101", "1", "1", "66", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.8", "80.6", "", "", "", "", "80.9"]} +{"pcdb_id": 8788, "brand_name": "Glow-worm", "model_name": "Micron 50FF", "model_qualifier": "", "winter_efficiency_pct": 79.8, "summer_efficiency_pct": 69.7, "comparative_hot_water_efficiency_pct": 50.9, "output_kw_max": 14.65, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008788", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Micron 50FF", "", "41 047 48", "2001", "current", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "11.72", "14.65", "", "", "79.8", "69.7", "", "50.9", "", "2", "", "", "101", "1", "1", "71", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.4", "81.5", "", "", "", "", "81.4"]} +{"pcdb_id": 8789, "brand_name": "Glow-worm", "model_name": "Micron 60 FF", "model_qualifier": "", "winter_efficiency_pct": 79.7, "summer_efficiency_pct": 69.6, "comparative_hot_water_efficiency_pct": 50.8, "output_kw_max": 17.58, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008789", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Micron 60 FF", "", "41 047 49", "2001", "current", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "14.65", "17.58", "", "", "79.7", "69.6", "", "50.8", "", "2", "", "", "101", "1", "1", "71", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.5", "81.0", "", "", "", "", "81.1"]} +{"pcdb_id": 8790, "brand_name": "Glow-worm", "model_name": "Micron 70 FF", "model_qualifier": "", "winter_efficiency_pct": 79.2, "summer_efficiency_pct": 69.1, "comparative_hot_water_efficiency_pct": 50.5, "output_kw_max": 20.51, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008790", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Micron 70 FF", "", "41 047 50", "2001", "current", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "17.58", "20.51", "", "", "79.2", "69.1", "", "50.5", "", "2", "", "", "101", "1", "1", "81", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "80.3", "81.4", "", "", "", "", "81.2"]} +{"pcdb_id": 8791, "brand_name": "Glow-worm", "model_name": "Micron 80 FF", "model_qualifier": "", "winter_efficiency_pct": 79.2, "summer_efficiency_pct": 69.1, "comparative_hot_water_efficiency_pct": 50.5, "output_kw_max": 23.45, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008791", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Micron 80 FF", "", "41 047 51", "2001", "current", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "20.51", "23.45", "", "", "79.2", "69.1", "", "50.5", "", "2", "", "", "101", "1", "1", "81", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.4", "80.3", "", "", "", "", "80.5"]} +{"pcdb_id": 8792, "brand_name": "Glow-worm", "model_name": "Micron 100FF", "model_qualifier": "", "winter_efficiency_pct": 80.4, "summer_efficiency_pct": 70.3, "comparative_hot_water_efficiency_pct": 51.4, "output_kw_max": 29.31, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008792", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Micron 100FF", "", "41 047 52", "2001", "current", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "23.45", "29.31", "", "", "80.4", "70.3", "", "51.4", "", "2", "", "", "101", "1", "1", "71", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.1", "82.0", "", "", "", "", "82.0"]} +{"pcdb_id": 8793, "brand_name": "Glow-worm", "model_name": "Ultimate 40 FF", "model_qualifier": "", "winter_efficiency_pct": 79.6, "summer_efficiency_pct": 69.5, "comparative_hot_water_efficiency_pct": 50.8, "output_kw_max": 11.72, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008793", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Ultimate 40 FF", "", "41 047 54", "2001", "current", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "10.26", "11.72", "", "", "79.6", "69.5", "", "50.8", "", "2", "", "", "101", "1", "1", "56", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "80.8", "81.6", "", "", "", "", "81.5"]} +{"pcdb_id": 8794, "brand_name": "Glow-worm", "model_name": "Ultimate 50 FF", "model_qualifier": "", "winter_efficiency_pct": 79.7, "summer_efficiency_pct": 69.6, "comparative_hot_water_efficiency_pct": 50.8, "output_kw_max": 14.65, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008794", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Ultimate 50 FF", "", "41 047 55", "2001", "current", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "11.72", "14.65", "", "", "79.7", "69.6", "", "50.8", "", "2", "", "", "101", "1", "1", "56", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.0", "81.5", "", "", "", "", "81.4"]} +{"pcdb_id": 8795, "brand_name": "Glow-worm", "model_name": "Ultimate 60 FF", "model_qualifier": "", "winter_efficiency_pct": 80.3, "summer_efficiency_pct": 70.2, "comparative_hot_water_efficiency_pct": 51.2, "output_kw_max": 17.59, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008795", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Ultimate 60 FF", "", "41 047 56", "2001", "current", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "14.65", "17.59", "", "", "80.3", "70.2", "", "51.2", "", "2", "", "", "101", "1", "1", "71", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.7", "82.0", "", "", "", "", "81.9"]} +{"pcdb_id": 8796, "brand_name": "Glow-worm", "model_name": "Ultimate 70 FF", "model_qualifier": "", "winter_efficiency_pct": 80.2, "summer_efficiency_pct": 70.1, "comparative_hot_water_efficiency_pct": 51.2, "output_kw_max": 20.52, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008796", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Ultimate 70 FF", "", "41 319 59", "2001", "current", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "17.58", "20.52", "", "", "80.2", "70.1", "", "51.2", "", "2", "", "", "101", "1", "1", "71", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.7", "81.8", "", "", "", "", "81.8"]} +{"pcdb_id": 8797, "brand_name": "Glow-worm", "model_name": "Ultimate 80 FF", "model_qualifier": "", "winter_efficiency_pct": 80.3, "summer_efficiency_pct": 70.2, "comparative_hot_water_efficiency_pct": 51.2, "output_kw_max": 23.45, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008797", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Ultimate 80 FF", "", "41 047 59", "2001", "current", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "20.52", "23.45", "", "", "80.3", "70.2", "", "51.2", "", "2", "", "", "101", "1", "1", "71", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.7", "82.0", "", "", "", "", "81.9"]} +{"pcdb_id": 8798, "brand_name": "Glow-worm", "model_name": "Ultimate 100 FF", "model_qualifier": "", "winter_efficiency_pct": 80.4, "summer_efficiency_pct": 70.3, "comparative_hot_water_efficiency_pct": 51.4, "output_kw_max": 29.31, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008798", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Ultimate 100 FF", "", "41 047 60", "2001", "current", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "23.45", "29.31", "", "", "80.4", "70.3", "", "51.4", "", "2", "", "", "101", "1", "1", "71", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.1", "82.0", "", "", "", "", "82.0"]} +{"pcdb_id": 8799, "brand_name": "Glow-worm", "model_name": "45/4 BBU", "model_qualifier": "", "winter_efficiency_pct": 79.3, "summer_efficiency_pct": 69.2, "comparative_hot_water_efficiency_pct": 50.5, "output_kw_max": 13.19, "final_year_of_manufacture": 2003, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008799", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "45/4 BBU", "", "44 047 06", "2001", "2003", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "8.79", "13.19", "", "", "79.3", "69.2", "", "50.5", "", "2", "", "", "101", "1", "1", "8", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "80.8", "80.9", "", "", "", "", "80.9"]} +{"pcdb_id": 8800, "brand_name": "Glow-worm", "model_name": "54/4 BBU", "model_qualifier": "", "winter_efficiency_pct": 79.8, "summer_efficiency_pct": 69.7, "comparative_hot_water_efficiency_pct": 50.9, "output_kw_max": 15.83, "final_year_of_manufacture": 2003, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008800", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "54/4 BBU", "", "44 047 05", "2001", "2003", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "13.19", "15.83", "", "", "79.8", "69.7", "", "50.9", "", "2", "", "", "101", "1", "1", "8", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "80.9", "81.9", "", "", "", "", "81.7"]} +{"pcdb_id": 8801, "brand_name": "Saunier Duval", "model_name": "Xeon 40ff", "model_qualifier": "", "winter_efficiency_pct": 79.6, "summer_efficiency_pct": 69.5, "comparative_hot_water_efficiency_pct": 50.8, "output_kw_max": 11.72, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008801", "000206", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Saunier Duval", "Xeon 40ff", "", "41 920 40", "2001", "current", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "10.26", "11.72", "", "", "79.6", "69.5", "", "50.8", "", "2", "", "", "101", "1", "1", "56", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "80.8", "81.6", "", "", "", "", "81.5"]} +{"pcdb_id": 8802, "brand_name": "Saunier Duval", "model_name": "Xeon 50ff", "model_qualifier": "", "winter_efficiency_pct": 79.7, "summer_efficiency_pct": 69.6, "comparative_hot_water_efficiency_pct": 50.8, "output_kw_max": 14.65, "final_year_of_manufacture": 2003, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008802", "000206", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Saunier Duval", "Xeon 50ff", "", "41 920 41", "2001", "2003", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "11.72", "14.65", "", "", "79.7", "69.6", "", "50.8", "", "2", "", "", "101", "1", "1", "56", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.0", "81.5", "", "", "", "", "81.4"]} +{"pcdb_id": 8803, "brand_name": "Saunier Duval", "model_name": "Xeon 60ff", "model_qualifier": "", "winter_efficiency_pct": 80.3, "summer_efficiency_pct": 70.2, "comparative_hot_water_efficiency_pct": 51.2, "output_kw_max": 17.59, "final_year_of_manufacture": 2003, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008803", "000206", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Saunier Duval", "Xeon 60ff", "", "41 920 42", "2001", "2003", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "14.65", "17.59", "", "", "80.3", "70.2", "", "51.2", "", "2", "", "", "101", "1", "1", "71", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.7", "82.0", "", "", "", "", "81.9"]} +{"pcdb_id": 8804, "brand_name": "Saunier Duval", "model_name": "Xeon 80 ff", "model_qualifier": "", "winter_efficiency_pct": 80.3, "summer_efficiency_pct": 70.2, "comparative_hot_water_efficiency_pct": 51.2, "output_kw_max": 23.45, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008804", "000206", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Saunier Duval", "Xeon 80 ff", "", "41 920 43", "2001", "current", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "20.52", "23.45", "", "", "80.3", "70.2", "", "51.2", "", "2", "", "", "101", "1", "1", "71", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.7", "82.0", "", "", "", "", "81.9"]} +{"pcdb_id": 8805, "brand_name": "Grant", "model_name": "Vortex", "model_qualifier": "15", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 58.8, "output_kw_max": 15.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008805", "000048", "0", "2012/Mar/27 10:12", "Grant Engineering", "Grant", "Vortex", "15", "", "2002", "current", "4", "1", "1", "1", "0", "", "", "2", "2", "2", "15", "15", "", "", "88.3", "80.5", "", "58.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "93.5", "94.5", "", "", "", "", "94.3"]} +{"pcdb_id": 8806, "brand_name": "Grant", "model_name": "Vortex", "model_qualifier": "20", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 80.9, "comparative_hot_water_efficiency_pct": 59.1, "output_kw_max": 20.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008806", "000048", "0", "2012/Mar/27 10:12", "Grant Engineering", "Grant", "Vortex", "20", "", "2002", "current", "4", "1", "1", "1", "0", "", "", "2", "2", "2", "20", "20", "", "", "88.7", "80.9", "", "59.1", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "93.9", "95.3", "", "", "", "", "95.0"]} +{"pcdb_id": 8807, "brand_name": "Grant", "model_name": "Vortex", "model_qualifier": "26", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 81.3, "comparative_hot_water_efficiency_pct": 59.4, "output_kw_max": 26.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008807", "000048", "0", "2012/Mar/27 10:12", "Grant Engineering", "Grant", "Vortex", "26", "", "2002", "current", "4", "1", "1", "1", "0", "", "", "2", "2", "2", "26", "26", "", "", "89.1", "81.3", "", "59.4", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "93.6", "96.4", "", "", "", "", "95.9"]} +{"pcdb_id": 8808, "brand_name": "Grant", "model_name": "Vortex", "model_qualifier": "15 S", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 58.8, "output_kw_max": 15.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008808", "000048", "0", "2012/Mar/27 10:12", "Grant Engineering", "Grant", "Vortex", "15 S", "", "2002", "current", "4", "1", "1", "1", "0", "", "", "2", "2", "2", "15", "15", "", "", "88.3", "80.5", "", "58.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "93.5", "94.5", "", "", "", "", "94.3"]} +{"pcdb_id": 8809, "brand_name": "Grant", "model_name": "Vortex", "model_qualifier": "20 S", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 80.9, "comparative_hot_water_efficiency_pct": 59.1, "output_kw_max": 20.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008809", "000048", "0", "2012/Mar/27 10:12", "Grant Engineering", "Grant", "Vortex", "20 S", "", "2002", "current", "4", "1", "1", "1", "0", "", "", "2", "2", "2", "20", "20", "", "", "88.7", "80.9", "", "59.1", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "93.9", "95.3", "", "", "", "", "95.0"]} +{"pcdb_id": 8810, "brand_name": "Grant", "model_name": "Vortex", "model_qualifier": "26 S", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 81.3, "comparative_hot_water_efficiency_pct": 59.4, "output_kw_max": 26.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008810", "000048", "0", "2012/Mar/27 10:12", "Grant Engineering", "Grant", "Vortex", "26 S", "", "2002", "current", "4", "1", "1", "1", "0", "", "", "2", "2", "2", "26", "26", "", "", "89.1", "81.3", "", "59.4", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "93.6", "96.4", "", "", "", "", "95.9"]} +{"pcdb_id": 8811, "brand_name": "Lamborghini", "model_name": "Futuria", "model_qualifier": "24 MCW Top U/GB", "winter_efficiency_pct": 87.6, "summer_efficiency_pct": 78.6, "comparative_hot_water_efficiency_pct": 57.4, "output_kw_max": 25.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008811", "000214", "0", "2012/Mar/27 10:12", "Lamborghini Calor SpA", "Lamborghini", "Futuria", "24 MCW Top U/GB", "900170-1", "1998", "current", "1", "1", "1", "1", "0", "", "", "2", "2", "2", "25.0", "25.0", "", "", "87.6", "78.6", "", "57.4", "", "2", "", "", "102", "1", "2", "274", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.4", "95.7", "", "", "", "", "94.3"]} +{"pcdb_id": 8812, "brand_name": "Lamborghini", "model_name": "Xilo", "model_qualifier": "20 MCS W Top U/GB", "winter_efficiency_pct": 77.5, "summer_efficiency_pct": 67.4, "comparative_hot_water_efficiency_pct": 47.4, "output_kw_max": 22.75, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008812", "000214", "0", "2006/Jan/17 12:31", "Lamborghini Calor SpA", "Lamborghini", "Xilo", "20 MCS W Top U/GB", "902820-1", "2000", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "22.75", "22.75", "", "", "77.5", "67.4", "", "47.4", "", "2", "", "", "104", "1", "2", "150", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.0", "75.3", "", "", "", "", "76.6"]} +{"pcdb_id": 8813, "brand_name": "Lamborghini", "model_name": "Xilo D", "model_qualifier": "24 MCS W Top U/GB", "winter_efficiency_pct": 79.8, "summer_efficiency_pct": 69.7, "comparative_hot_water_efficiency_pct": 49.0, "output_kw_max": 27.48, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008813", "000214", "0", "2006/Jan/17 12:31", "Lamborghini Calor SpA", "Lamborghini", "Xilo D", "24 MCS W Top U/GB", "903790", "2001", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "27.48", "27.48", "", "", "79.8", "69.7", "", "49.0", "", "2", "", "", "104", "1", "2", "175", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.0", "80.1", "", "", "", "", "80.5"]} +{"pcdb_id": 8814, "brand_name": "Lamborghini", "model_name": "Vela X", "model_qualifier": "24 MBS W Top/GB", "winter_efficiency_pct": 79.6, "summer_efficiency_pct": 70.5, "comparative_hot_water_efficiency_pct": 38.1, "output_kw_max": 27.8, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 1, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008814", "000214", "0", "2024/Jan/31 10:17", "Lamborghini Calor SpA", "Lamborghini", "Vela X", "24 MBS W Top/GB", "903200", "2001", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "27.8", "27.8", "", "", "79.6", "70.5", "", "38.1", "", "2", "", "", "106", "1", "2", "153", "0", "1", "1", "0", "67.5", "0", "30", "1", "60", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.3", "78.7", "", "", "", "", "79.4"]} +{"pcdb_id": 8815, "brand_name": "Lamborghini", "model_name": "ALBA", "model_qualifier": "24 ASB", "winter_efficiency_pct": 79.6, "summer_efficiency_pct": 70.5, "comparative_hot_water_efficiency_pct": 38.1, "output_kw_max": 27.8, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 1, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008815", "000214", "0", "2024/Jan/31 10:17", "Finterm SpA", "Lamborghini", "ALBA", "24 ASB", "9879025847", "2002", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "27.8", "27.8", "", "", "79.6", "70.5", "", "38.1", "", "2", "", "", "106", "1", "2", "153", "", "1", "1", "0", "67.5", "0", "30", "1", "60", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.3", "78.7", "", "", "", "", "79.4"]} +{"pcdb_id": 8816, "brand_name": "Lamborghini", "model_name": "ALBA", "model_qualifier": "20 ASB", "winter_efficiency_pct": 80.5, "summer_efficiency_pct": 71.4, "comparative_hot_water_efficiency_pct": 38.6, "output_kw_max": 23.9, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 1, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008816", "000214", "0", "2024/Jan/31 10:17", "Finterm SpA", "Lamborghini", "ALBA", "20 ASB", "9879020847", "2002", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "23.9", "23.9", "", "", "80.5", "71.4", "", "38.6", "", "2", "", "", "106", "1", "2", "150", "", "1", "1", "0", "67.5", "0", "30", "1", "60", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.9", "79.9", "", "", "", "", "80.5"]} +{"pcdb_id": 8817, "brand_name": "Lamborghini", "model_name": "ALBA", "model_qualifier": "24 AS", "winter_efficiency_pct": 79.8, "summer_efficiency_pct": 69.7, "comparative_hot_water_efficiency_pct": 49.0, "output_kw_max": 27.48, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008817", "000214", "0", "2006/Jan/17 12:31", "Finterm SpA", "Lamborghini", "ALBA", "24 AS", "9879025447", "2001", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "27.48", "27.48", "", "", "79.8", "69.7", "", "49.0", "", "2", "", "", "104", "1", "2", "175", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.0", "80.1", "", "", "", "", "80.5"]} +{"pcdb_id": 8818, "brand_name": "Lamborghini", "model_name": "ALBA", "model_qualifier": "20 AS", "winter_efficiency_pct": 80.0, "summer_efficiency_pct": 69.9, "comparative_hot_water_efficiency_pct": 49.2, "output_kw_max": 23.7, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008818", "000214", "0", "2006/Jan/17 12:31", "Finterm SpA", "Lamborghini", "ALBA", "20 AS", "9879020447", "2002", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "23.7", "23.7", "", "", "80.0", "69.9", "", "49.2", "", "2", "", "", "104", "1", "2", "175", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.3", "80.2", "", "", "", "", "80.6"]} +{"pcdb_id": 8819, "brand_name": "Lamborghini", "model_name": "ALBA", "model_qualifier": "20 BS", "winter_efficiency_pct": 77.5, "summer_efficiency_pct": 67.4, "comparative_hot_water_efficiency_pct": 47.4, "output_kw_max": 22.75, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008819", "000214", "0", "2006/Jan/17 12:31", "Finterm SpA", "Lamborghini", "ALBA", "20 BS", "9878020447", "2002", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "22.75", "22.75", "", "", "77.5", "67.4", "", "47.4", "", "2", "", "", "104", "1", "2", "175", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.0", "75.3", "", "", "", "", "76.6"]} +{"pcdb_id": 8820, "brand_name": "Lamborghini", "model_name": "ALBA", "model_qualifier": "24 RS", "winter_efficiency_pct": 80.0, "summer_efficiency_pct": 69.3, "comparative_hot_water_efficiency_pct": 50.7, "output_kw_max": 27.48, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008820", "000214", "0", "2012/Mar/27 10:12", "Finterm SpA", "Lamborghini", "ALBA", "24 RS", "9879025247", "2002", "current", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "27.48", "27.48", "", "", "80.0", "69.3", "", "50.7", "", "2", "", "", "102", "1", "2", "175", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.0", "80.1", "", "", "", "", "80.5"]} +{"pcdb_id": 8827, "brand_name": "Glow-worm", "model_name": "24ci", "model_qualifier": "", "winter_efficiency_pct": 79.2, "summer_efficiency_pct": 69.1, "comparative_hot_water_efficiency_pct": 48.6, "output_kw_max": 23.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008827", "000207", "0", "2006/Jan/17 12:31", "Hepworth Heating", "Glow-worm", "24ci", "", "GC 47-047-19", "2001", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "23.6", "23.6", "", "", "79.2", "69.1", "", "48.6", "", "2", "", "", "104", "1", "2", "122", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.4", "79.5", "", "", "", "", "79.8"]} +{"pcdb_id": 8828, "brand_name": "Saunier Duval", "model_name": "Thema Classic F24E", "model_qualifier": "", "winter_efficiency_pct": 79.2, "summer_efficiency_pct": 69.1, "comparative_hot_water_efficiency_pct": 48.6, "output_kw_max": 23.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008828", "000206", "0", "2006/Jan/17 12:31", "Hepworth Heating", "Saunier Duval", "Thema Classic F24E", "", "GC 47-920-35", "2001", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "23.6", "23.6", "", "", "79.2", "69.1", "", "48.6", "", "2", "", "", "104", "1", "2", "122", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.4", "79.5", "", "", "", "", "79.8"]} +{"pcdb_id": 8829, "brand_name": "Glow-worm", "model_name": "Xtrafast 120", "model_qualifier": "", "winter_efficiency_pct": 79.5, "summer_efficiency_pct": 69.4, "comparative_hot_water_efficiency_pct": 48.8, "output_kw_max": 34.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008829", "000207", "0", "2006/Jan/17 12:31", "Saunier Duval", "Glow-worm", "Xtrafast 120", "", "GC 47-920-18", "2000", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "34.6", "34.6", "", "", "79.5", "69.4", "", "48.8", "", "2", "", "", "104", "1", "2", "220", "50", "0", "", "", "0", "0", "0", "", "0", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "83.2", "78.5", "", "", "", "", "79.4"]} +{"pcdb_id": 8830, "brand_name": "Glow-worm", "model_name": "Xtrafast 96", "model_qualifier": "", "winter_efficiency_pct": 80.3, "summer_efficiency_pct": 70.2, "comparative_hot_water_efficiency_pct": 49.4, "output_kw_max": 27.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008830", "000207", "0", "2006/Jan/17 12:31", "Saunier Duval", "Glow-worm", "Xtrafast 96", "", "GC 47-920-15", "2000", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "27.6", "27.6", "", "", "80.3", "70.2", "", "49.4", "", "2", "", "", "104", "1", "2", "220", "50", "0", "", "", "0", "0", "0", "", "0", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.4", "80.6", "", "", "", "", "81.0"]} +{"pcdb_id": 8831, "brand_name": "Saunier Duval", "model_name": "Isofast F35E", "model_qualifier": "", "winter_efficiency_pct": 79.5, "summer_efficiency_pct": 69.4, "comparative_hot_water_efficiency_pct": 48.8, "output_kw_max": 34.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008831", "000206", "0", "2012/Mar/26 14:28", "Saunier Duval", "Saunier Duval", "Isofast F35E", "", "GC 47-920-18", "2000", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "34.6", "34.6", "", "", "79.5", "69.4", "", "48.8", "", "2", "", "", "104", "1", "2", "220", "50", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "2", "0", "50", "0004", "", "", "", "", "", "", "", "", "83.2", "78.5", "", "", "", "", "79.4"]} +{"pcdb_id": 8832, "brand_name": "Saunier Duval", "model_name": "Isofast F28E", "model_qualifier": "", "winter_efficiency_pct": 80.3, "summer_efficiency_pct": 70.2, "comparative_hot_water_efficiency_pct": 49.4, "output_kw_max": 27.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008832", "000206", "0", "2012/Apr/03 11:16", "Saunier Duval", "Saunier Duval", "Isofast F28E", "", "GC 47-920-15", "2000", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "27.6", "27.6", "", "", "80.3", "70.2", "", "49.4", "", "2", "", "", "104", "1", "2", "220", "50", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "2", "0", "50", "0004", "", "", "", "", "", "", "", "", "82.4", "80.6", "", "", "", "", "81.0"]} +{"pcdb_id": 8833, "brand_name": "Worcester", "model_name": "Highflow 400 Electronic RSF", "model_qualifier": "RSF", "winter_efficiency_pct": 81.1, "summer_efficiency_pct": 72.0, "comparative_hot_water_efficiency_pct": 37.1, "output_kw_max": 24.0, "final_year_of_manufacture": 2005, "subsidiary_type": 0, "store_type": 1, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008833", "000035", "0", "2024/Jan/31 10:17", "Worcester Heat Systems", "Worcester", "Highflow 400 Electronic RSF", "RSF", "47 311 64", "2002", "2005", "2", "1", "1", "2", "0", "", "", "1", "2", "2", "24", "24", "", "", "81.1", "72.0", "", "37.1", "", "2", "0", "", "106", "1", "2", "", "", "1", "1", "0", "65", "0", "25", "3", "75", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "84.1", "79.9", "", "", "", "", "80.7"]} +{"pcdb_id": 8834, "brand_name": "Worcester", "model_name": "Highflow 400 Electronic RSF", "model_qualifier": "RSF", "winter_efficiency_pct": 79.6, "summer_efficiency_pct": 70.5, "comparative_hot_water_efficiency_pct": 36.3, "output_kw_max": 24.0, "final_year_of_manufacture": 2005, "subsidiary_type": 0, "store_type": 1, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008834", "000035", "0", "2024/Jan/31 10:17", "Worcester Heat Systems", "Worcester", "Highflow 400 Electronic RSF", "RSF", "47 311 61", "2002", "2005", "1", "1", "1", "2", "0", "", "", "1", "2", "2", "24", "24", "", "", "79.6", "70.5", "", "36.3", "", "2", "", "", "106", "1", "2", "", "", "1", "1", "0", "65", "0", "25", "3", "75", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.2", "78.9", "", "", "", "", "79.5"]} +{"pcdb_id": 8835, "brand_name": "Worcester", "model_name": "Highflow 400 Electronic BF", "model_qualifier": "BF", "winter_efficiency_pct": 80.8, "summer_efficiency_pct": 71.7, "comparative_hot_water_efficiency_pct": 36.9, "output_kw_max": 24.0, "final_year_of_manufacture": 2005, "subsidiary_type": 0, "store_type": 1, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008835", "000035", "0", "2024/Jan/31 10:17", "Worcester Heat Systems", "Worcester", "Highflow 400 Electronic BF", "BF", "47 311 62", "2002", "2005", "1", "1", "1", "2", "0", "", "", "1", "2", "1", "24", "24", "", "", "80.8", "71.7", "", "36.9", "", "2", "", "", "106", "1", "2", "", "", "1", "1", "0", "65", "0", "25", "3", "75", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.8", "80.5", "", "", "", "", "81.0"]} +{"pcdb_id": 8836, "brand_name": "Worcester", "model_name": "Highflow 400 Electronic OF", "model_qualifier": "OF", "winter_efficiency_pct": 79.3, "summer_efficiency_pct": 70.2, "comparative_hot_water_efficiency_pct": 36.1, "output_kw_max": 24.0, "final_year_of_manufacture": 2005, "subsidiary_type": 0, "store_type": 1, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008836", "000035", "0", "2024/Jan/31 10:17", "Worcester Heat Systems", "Worcester", "Highflow 400 Electronic OF", "OF", "47 311 63", "2002", "2005", "1", "1", "1", "2", "0", "", "", "1", "1", "1", "24", "24", "", "", "79.3", "70.2", "", "36.1", "", "2", "", "", "106", "1", "2", "", "", "1", "1", "0", "65", "0", "25", "3", "75", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.4", "79.0", "", "", "", "", "79.5"]} +{"pcdb_id": 8843, "brand_name": "HRM Boilers", "model_name": "Wallstar 20/25", "model_qualifier": "13", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 25.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008843", "000098", "0", "2012/Mar/27 10:12", "HRM Boilers", "HRM Boilers", "Wallstar 20/25", "13", "10021218", "2002", "current", "4", "2", "1", "1", "0", "", "", "1", "2", "2", "20", "25", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "140", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.3", "87.5", "", "", "", "", "87.3"]} +{"pcdb_id": 8844, "brand_name": "Ariston", "model_name": "Genus 27 BFFI Plus", "model_qualifier": "Mk2", "winter_efficiency_pct": 80.8, "summer_efficiency_pct": 71.7, "comparative_hot_water_efficiency_pct": 38.0, "output_kw_max": 27.4, "final_year_of_manufacture": 2007, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008844", "000080", "0", "2024/Jan/31 10:17", "Merloni TermoSanitari SpA", "Ariston", "Genus 27 BFFI Plus", "Mk2", "GC No. 47-116-11", "2002", "2007", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "27.4", "27.4", "", "", "80.8", "71.7", "", "38.0", "", "2", "", "", "106", "1", "2", "200", "7", "2", "2", "0", "52", "0", "15", "2", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "83.0", "80.0", "", "", "", "", "80.6"]} +{"pcdb_id": 8845, "brand_name": "Ariston", "model_name": "Ecogenus 24 RFFI System", "model_qualifier": "Mk2", "winter_efficiency_pct": 87.6, "summer_efficiency_pct": 78.6, "comparative_hot_water_efficiency_pct": 57.4, "output_kw_max": 24.5, "final_year_of_manufacture": 2003, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008845", "000080", "0", "2012/Mar/27 10:12", "Merloni TermoSanitari SpA", "Ariston", "Ecogenus 24 RFFI System", "Mk2", "GC No. 41-116-03", "2002", "2003", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24.5", "24.5", "", "", "87.6", "78.6", "", "57.4", "", "2", "", "", "102", "1", "2", "130", "7", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.7", "95.9", "", "", "", "", "94.3"]} +{"pcdb_id": 8846, "brand_name": "Ariston", "model_name": "Ecogenus 24 MFFI", "model_qualifier": "Mk2", "winter_efficiency_pct": 87.6, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 55.5, "output_kw_max": 24.5, "final_year_of_manufacture": 2003, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008846", "000080", "0", "2006/Jan/17 12:55", "Merloni TermoSanitari SpA", "Ariston", "Ecogenus 24 MFFI", "Mk2", "GC No. 47-116-17", "2002", "2003", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.5", "24.5", "", "", "87.6", "79.0", "", "55.5", "", "2", "", "", "104", "1", "2", "130", "5", "0", "1", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.7", "95.9", "", "", "", "", "94.3"]} +{"pcdb_id": 8847, "brand_name": "Halstead", "model_name": "Finest", "model_qualifier": "fpx", "winter_efficiency_pct": 82.0, "summer_efficiency_pct": 71.9, "comparative_hot_water_efficiency_pct": 50.5, "output_kw_max": 26.4, "final_year_of_manufacture": 2006, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008847", "000019", "0", "2008/Feb/19 10:12", "Halstead Boilers", "Halstead", "Finest", "fpx", "", "2002", "2006", "2", "2", "1", "2", "0", "", "", "1", "2", "2", "26.4", "26.4", "", "", "82.0", "71.9", "", "50.5", "", "2", "1", "", "104", "1", "2", "150", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "83.3", "83.1", "", "", "", "", "83.1"]} +{"pcdb_id": 8848, "brand_name": "Halstead", "model_name": "Best 40 P", "model_qualifier": "", "winter_efficiency_pct": 81.3, "summer_efficiency_pct": 71.2, "comparative_hot_water_efficiency_pct": 52.0, "output_kw_max": 13.4, "final_year_of_manufacture": 2006, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008848", "000019", "0", "2012/Mar/27 10:12", "Halstead Boilers", "Halstead", "Best 40 P", "", "DBPX40", "2002", "2006", "2", "2", "1", "1", "0", "", "", "1", "2", "2", "0", "13.4", "", "", "81.3", "71.2", "", "52.0", "", "2", "1", "", "101", "1", "1", "45", "5", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "83.1", "82.8", "", "", "", "", "82.9"]} +{"pcdb_id": 8849, "brand_name": "Halstead", "model_name": "Best 60 P", "model_qualifier": "", "winter_efficiency_pct": 81.9, "summer_efficiency_pct": 71.8, "comparative_hot_water_efficiency_pct": 52.4, "output_kw_max": 19.8, "final_year_of_manufacture": 2006, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008849", "000019", "0", "2012/Mar/27 10:12", "Halstead Boilers", "Halstead", "Best 60 P", "", "DBPX60", "2002", "2006", "2", "2", "1", "1", "0", "", "", "1", "2", "2", "0", "19.8", "", "", "81.9", "71.8", "", "52.4", "", "2", "1", "", "101", "1", "1", "45", "5", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "83.4", "83.6", "", "", "", "", "83.6"]} +{"pcdb_id": 8850, "brand_name": "Worcester", "model_name": "Danesmoor", "model_qualifier": "20/25-000-GB-L", "winter_efficiency_pct": 85.3, "summer_efficiency_pct": 73.6, "comparative_hot_water_efficiency_pct": 53.7, "output_kw_max": 25.0, "final_year_of_manufacture": 2008, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008850", "000035", "0", "2020/Sep/04 07:57", "Worcester Heat Systems", "Worcester", "Danesmoor", "20/25-000-GB-L", "C16395/1", "2001", "2008", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "20", "25", "", "", "85.3", "73.6", "", "53.7", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.3", "85.3", "", "", "", "", "85.3"]} +{"pcdb_id": 8851, "brand_name": "Worcester", "model_name": "Danesmoor", "model_qualifier": "20/25 - R00-GB-L", "winter_efficiency_pct": 85.3, "summer_efficiency_pct": 73.6, "comparative_hot_water_efficiency_pct": 53.7, "output_kw_max": 25.0, "final_year_of_manufacture": 2008, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008851", "000035", "0", "2020/Sep/04 07:57", "Worcester Heat Systems", "Worcester", "Danesmoor", "20/25 - R00-GB-L", "C16395/1", "2001", "2008", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "20", "25", "", "", "85.3", "73.6", "", "53.7", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.3", "85.3", "", "", "", "", "85.3"]} +{"pcdb_id": 8852, "brand_name": "Worcester", "model_name": "Danesmoor Utility", "model_qualifier": "20/25-000-GB-L Utility", "winter_efficiency_pct": 85.3, "summer_efficiency_pct": 73.6, "comparative_hot_water_efficiency_pct": 53.7, "output_kw_max": 25.0, "final_year_of_manufacture": 2008, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008852", "000035", "0", "2020/Sep/04 07:57", "Worcester Heat Systems", "Worcester", "Danesmoor Utility", "20/25-000-GB-L Utility", "C16395/1", "2001", "2008", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "20", "25", "", "", "85.3", "73.6", "", "53.7", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.3", "85.3", "", "", "", "", "85.3"]} +{"pcdb_id": 8853, "brand_name": "Worcester", "model_name": "Danesmoor Utility", "model_qualifier": "20/25-R00-GB-L Utility", "winter_efficiency_pct": 85.3, "summer_efficiency_pct": 73.6, "comparative_hot_water_efficiency_pct": 53.7, "output_kw_max": 25.0, "final_year_of_manufacture": 2008, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008853", "000035", "0", "2020/Sep/04 07:58", "Worcester Heat Systems", "Worcester", "Danesmoor Utility", "20/25-R00-GB-L Utility", "C16395/1", "2001", "2008", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "20", "25", "", "", "85.3", "73.6", "", "53.7", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.3", "85.3", "", "", "", "", "85.3"]} +{"pcdb_id": 8854, "brand_name": "Worcester", "model_name": "Danesmoor System", "model_qualifier": "20/25-0S0-GB-L System", "winter_efficiency_pct": 85.3, "summer_efficiency_pct": 73.6, "comparative_hot_water_efficiency_pct": 53.7, "output_kw_max": 25.0, "final_year_of_manufacture": 2008, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008854", "000035", "0", "2020/Sep/04 07:58", "Worcester Heat Systems", "Worcester", "Danesmoor System", "20/25-0S0-GB-L System", "C16395/1", "2001", "2008", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "20", "25", "", "", "85.3", "73.6", "", "53.7", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.3", "85.3", "", "", "", "", "85.3"]} +{"pcdb_id": 8855, "brand_name": "Worcester", "model_name": "Danesmoor System", "model_qualifier": "20/25-RS0-GB-L System", "winter_efficiency_pct": 85.3, "summer_efficiency_pct": 73.6, "comparative_hot_water_efficiency_pct": 53.7, "output_kw_max": 25.0, "final_year_of_manufacture": 2008, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008855", "000035", "0", "2020/Sep/04 07:58", "Worcester Heat Systems", "Worcester", "Danesmoor System", "20/25-RS0-GB-L System", "C16395/1", "2001", "2008", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "20", "25", "", "", "85.3", "73.6", "", "53.7", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.3", "85.3", "", "", "", "", "85.3"]} +{"pcdb_id": 8856, "brand_name": "Worcester", "model_name": "Bosch", "model_qualifier": "70/90-000-NI-L", "winter_efficiency_pct": 85.3, "summer_efficiency_pct": 73.6, "comparative_hot_water_efficiency_pct": 53.7, "output_kw_max": 25.0, "final_year_of_manufacture": 2008, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008856", "000035", "0", "2020/Sep/04 07:58", "Worcester Heat Systems", "Worcester", "Bosch", "70/90-000-NI-L", "C16395/1", "2001", "2008", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "20", "25", "", "", "85.3", "73.6", "", "53.7", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.3", "85.3", "", "", "", "", "85.3"]} +{"pcdb_id": 8857, "brand_name": "Worcester", "model_name": "Danesmoor", "model_qualifier": "12/14-000-GB-L", "winter_efficiency_pct": 85.5, "summer_efficiency_pct": 73.8, "comparative_hot_water_efficiency_pct": 53.9, "output_kw_max": 14.0, "final_year_of_manufacture": 2008, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008857", "000035", "0", "2020/Sep/04 07:58", "Worcester Heat Systems", "Worcester", "Danesmoor", "12/14-000-GB-L", "C16394/1", "2001", "2008", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "12", "14", "", "", "85.5", "73.8", "", "53.9", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.4", "85.5", "", "", "", "", "85.5"]} +{"pcdb_id": 8858, "brand_name": "Worcester", "model_name": "Danesmoor", "model_qualifier": "12/14-R00-GB-L", "winter_efficiency_pct": 85.5, "summer_efficiency_pct": 73.8, "comparative_hot_water_efficiency_pct": 53.9, "output_kw_max": 14.0, "final_year_of_manufacture": 2008, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008858", "000035", "0", "2020/Sep/04 07:58", "Worcester Heat Systems", "Worcester", "Danesmoor", "12/14-R00-GB-L", "C16394/1", "2001", "2008", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "12", "14", "", "", "85.5", "73.8", "", "53.9", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.4", "85.5", "", "", "", "", "85.5"]} +{"pcdb_id": 8859, "brand_name": "Worcester", "model_name": "Danesmoor Utility", "model_qualifier": "12/14-000-GB-L Utility", "winter_efficiency_pct": 85.5, "summer_efficiency_pct": 73.8, "comparative_hot_water_efficiency_pct": 53.9, "output_kw_max": 14.0, "final_year_of_manufacture": 2008, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008859", "000035", "0", "2020/Sep/04 07:59", "Worcester Heat Systems", "Worcester", "Danesmoor Utility", "12/14-000-GB-L Utility", "C16394/1", "2001", "2008", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "12", "14", "", "", "85.5", "73.8", "", "53.9", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.4", "85.5", "", "", "", "", "85.5"]} +{"pcdb_id": 8860, "brand_name": "Worcester", "model_name": "Danesmoor Utility", "model_qualifier": "12/14-R00-GB-L Utility", "winter_efficiency_pct": 85.5, "summer_efficiency_pct": 73.8, "comparative_hot_water_efficiency_pct": 53.9, "output_kw_max": 14.0, "final_year_of_manufacture": 2008, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008860", "000035", "0", "2020/Sep/04 07:59", "Worcester Heat Systems", "Worcester", "Danesmoor Utility", "12/14-R00-GB-L Utility", "C16394/1", "2001", "2008", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "12", "14", "", "", "85.5", "73.8", "", "53.9", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.4", "85.5", "", "", "", "", "85.5"]} +{"pcdb_id": 8861, "brand_name": "Worcester", "model_name": "Danesmoor System", "model_qualifier": "12/14-0S0-GB-L System", "winter_efficiency_pct": 85.5, "summer_efficiency_pct": 73.8, "comparative_hot_water_efficiency_pct": 53.9, "output_kw_max": 14.0, "final_year_of_manufacture": 2008, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008861", "000035", "0", "2020/Sep/04 07:59", "Worcester Heat Systems", "Worcester", "Danesmoor System", "12/14-0S0-GB-L System", "C16394/1", "2001", "2008", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "12", "14", "", "", "85.5", "73.8", "", "53.9", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.4", "85.5", "", "", "", "", "85.5"]} +{"pcdb_id": 8862, "brand_name": "Worcester", "model_name": "Danesmoor System", "model_qualifier": "12/14-RS0-GB-L System", "winter_efficiency_pct": 85.5, "summer_efficiency_pct": 73.8, "comparative_hot_water_efficiency_pct": 53.9, "output_kw_max": 14.0, "final_year_of_manufacture": 2008, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008862", "000035", "0", "2020/Sep/04 07:59", "Worcester Heat Systems", "Worcester", "Danesmoor System", "12/14-RS0-GB-L System", "C16394/1", "2001", "2008", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "12", "14", "", "", "85.5", "73.8", "", "53.9", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.4", "85.5", "", "", "", "", "85.5"]} +{"pcdb_id": 8863, "brand_name": "Radiant", "model_name": "RBS 20 E", "model_qualifier": "Midy", "winter_efficiency_pct": 80.5, "summer_efficiency_pct": 70.4, "comparative_hot_water_efficiency_pct": 49.5, "output_kw_max": 26.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008863", "000088", "0", "2008/Feb/19 10:31", "Radiant Bruciatori SpA", "Radiant", "RBS 20 E", "Midy", "", "2002", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "26.60", "26.60", "", "", "80.5", "70.4", "", "49.5", "", "2", "", "", "104", "1", "2", "170", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "83.6", "80.5", "", "", "", "", "81.1"]} +{"pcdb_id": 8864, "brand_name": "Radiant", "model_name": "RS 24 E", "model_qualifier": "Midy", "winter_efficiency_pct": 80.4, "summer_efficiency_pct": 69.7, "comparative_hot_water_efficiency_pct": 50.9, "output_kw_max": 29.8, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008864", "000088", "0", "2012/Mar/27 10:12", "Radiant Bruciatori SpA", "Radiant", "RS 24 E", "Midy", "", "2002", "current", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "29.80", "29.80", "", "", "80.4", "69.7", "", "50.9", "", "2", "", "", "102", "1", "2", "170", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.5", "80.3", "", "", "", "", "80.7"]} +{"pcdb_id": 8865, "brand_name": "Radiant", "model_name": "RSF 24 E", "model_qualifier": "Slim", "winter_efficiency_pct": 80.2, "summer_efficiency_pct": 70.1, "comparative_hot_water_efficiency_pct": 49.3, "output_kw_max": 29.8, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008865", "000088", "0", "2008/Feb/19 10:33", "Radiant Bruciatori SpA", "Radiant", "RSF 24 E", "Slim", "", "2002", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "29.80", "29.80", "", "", "80.2", "70.1", "", "49.3", "", "2", "", "", "104", "1", "2", "170", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.5", "80.3", "", "", "", "", "80.7"]} +{"pcdb_id": 8866, "brand_name": "Baxi Potterton", "model_name": "Potterton Promax", "model_qualifier": "24 HE", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 22.0, "final_year_of_manufacture": 2005, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008866", "000005", "0", "2012/Mar/27 10:12", "Baxi Potterton", "Baxi Potterton", "Potterton Promax", "24 HE", "GC No. 41-590-62", "2002", "2005", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "22.0", "22.0", "", "", "88.8", "79.8", "", "58.3", "", "2", "", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.5", "98.1", "", "", "", "", "96.5"]} +{"pcdb_id": 8867, "brand_name": "Baxi Potterton", "model_name": "Potterton Promax", "model_qualifier": "15 HE", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 15.24, "final_year_of_manufacture": 2005, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008867", "000005", "0", "2012/Mar/27 10:12", "Baxi Potterton", "Baxi Potterton", "Potterton Promax", "15 HE", "GC No. 41-590-58", "2002", "2005", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "15.24", "15.24", "", "", "88.7", "79.7", "", "58.2", "", "2", "", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.3", "97.7", "", "", "", "", "96.3"]} +{"pcdb_id": 8868, "brand_name": "Baxi", "model_name": "100 HE", "model_qualifier": "", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 30.18, "final_year_of_manufacture": 2004, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008868", "000005", "0", "2012/Mar/27 10:12", "Baxi Potterton", "Baxi", "100 HE", "", "GC No. 47-590-62", "2002", "2004", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "30.18", "30.18", "", "", "88.9", "79.9", "", "58.4", "", "2", "", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.4", "98.5", "", "", "", "", "96.8"]} +{"pcdb_id": 8869, "brand_name": "Baxi", "model_name": "Solo 3 PFL System", "model_qualifier": "80", "winter_efficiency_pct": 79.6, "summer_efficiency_pct": 69.5, "comparative_hot_water_efficiency_pct": 50.8, "output_kw_max": 23.44, "final_year_of_manufacture": 2006, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008869", "000005", "0", "2012/Mar/27 10:12", "Baxi Potterton", "Baxi", "Solo 3 PFL System", "80", "GC No. 41-075-31", "2001", "2006", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "23.44", "23.44", "", "", "79.6", "69.5", "", "50.8", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.4", "81.1", "", "", "", "", "81.1"]} +{"pcdb_id": 8870, "brand_name": "Baxi", "model_name": "Solo 3 PFL", "model_qualifier": "80", "winter_efficiency_pct": 80.0, "summer_efficiency_pct": 69.9, "comparative_hot_water_efficiency_pct": 51.0, "output_kw_max": 23.44, "final_year_of_manufacture": 2010, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008870", "000005", "0", "2012/Mar/27 10:12", "Baxi Potterton", "Baxi", "Solo 3 PFL", "80", "GC No. 41-075-30", "2001", "2010", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "23.44", "23.44", "", "", "80.0", "69.9", "", "51.0", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.4", "81.8", "", "", "", "", "81.7"]} +{"pcdb_id": 8871, "brand_name": "Baxi Potterton", "model_name": "Baxi Combi", "model_qualifier": "130 HE", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 55.9, "output_kw_max": 30.0, "final_year_of_manufacture": 2004, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008871", "000005", "0", "2009/Oct/26 16:56", "Baxi Potterton", "Baxi Potterton", "Baxi Combi", "130 HE", "GC No. 47-590-04", "2002", "2004", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "30.00", "30.00", "", "", "88.1", "79.5", "", "55.9", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.2", "96.6", "", "", "", "", "95.2"]} +{"pcdb_id": 8872, "brand_name": "Glow-worm", "model_name": "18hxi", "model_qualifier": "", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 78.9, "comparative_hot_water_efficiency_pct": 57.6, "output_kw_max": 18.57, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008872", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "18hxi", "", "GC 41-047-63", "2002", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18.57", "18.57", "", "", "87.9", "78.9", "", "57.6", "", "2", "", "", "102", "1", "2", "60", "15", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.6", "96.3", "", "", "", "", "94.8"]} +{"pcdb_id": 8873, "brand_name": "Glow-worm", "model_name": "30hxi", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 28.17, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008873", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "30hxi", "", "GC 41-047-64", "2002", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "28.17", "28.17", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "60", "15", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.7", "96.4", "", "", "", "", "95.0"]} +{"pcdb_id": 8874, "brand_name": "Glow-worm", "model_name": "30sxi", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 28.17, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008874", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "30sxi", "", "GC 47-047-62", "2002", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "28.17", "28.17", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "180", "15", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.7", "96.4", "", "", "", "", "95.0"]} +{"pcdb_id": 8875, "brand_name": "Glow-worm", "model_name": "30cxi", "model_qualifier": "", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 55.8, "output_kw_max": 22.94, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008875", "000207", "0", "2006/Jan/17 12:31", "Hepworth Heating", "Glow-worm", "30cxi", "", "GC 47-047-24", "2002", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "22.94", "22.94", "", "", "87.9", "79.3", "", "55.8", "", "2", "", "", "104", "1", "2", "180", "15", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "96.4", "", "", "", "", "94.9"]} +{"pcdb_id": 8876, "brand_name": "Glow-worm", "model_name": "24cxi", "model_qualifier": "", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 55.8, "output_kw_max": 18.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008876", "000207", "0", "2006/Jan/17 12:31", "Hepworth Heating", "Glow-worm", "24cxi", "", "GC 47-047-23", "2002", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "18", "18", "", "", "87.9", "79.3", "", "55.8", "", "2", "", "", "104", "1", "2", "180", "15", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.6", "96.3", "", "", "", "", "94.8"]} +{"pcdb_id": 8877, "brand_name": "Glow-worm", "model_name": "BBU 54/4", "model_qualifier": "Miami 4", "winter_efficiency_pct": 79.7, "summer_efficiency_pct": 69.6, "comparative_hot_water_efficiency_pct": 50.8, "output_kw_max": 15.83, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008877", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "BBU 54/4", "Miami 4", "44 047 05", "2001", "current", "1", "4", "1", "1", "0", "", "", "1", "1", "1", "13.19", "15.83", "", "", "79.7", "69.6", "", "50.8", "", "2", "", "", "101", "1", "1", "8", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "80.9", "81.6", "", "", "", "", "81.5"]} +{"pcdb_id": 8878, "brand_name": "Glow-worm", "model_name": "BBU 54/4", "model_qualifier": "Firelite 4", "winter_efficiency_pct": 79.7, "summer_efficiency_pct": 69.6, "comparative_hot_water_efficiency_pct": 50.8, "output_kw_max": 15.83, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008878", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "BBU 54/4", "Firelite 4", "44 047 05", "2001", "current", "1", "4", "1", "1", "0", "", "", "1", "1", "1", "13.19", "15.83", "", "", "79.7", "69.6", "", "50.8", "", "2", "", "", "101", "1", "1", "8", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "80.9", "81.6", "", "", "", "", "81.5"]} +{"pcdb_id": 8879, "brand_name": "Glow-worm", "model_name": "BBU 54/4", "model_qualifier": "Contour 4", "winter_efficiency_pct": 79.7, "summer_efficiency_pct": 69.6, "comparative_hot_water_efficiency_pct": 50.8, "output_kw_max": 15.83, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008879", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "BBU 54/4", "Contour 4", "44 047 05", "2001", "current", "1", "4", "1", "1", "0", "", "", "1", "1", "1", "13.19", "15.83", "", "", "79.7", "69.6", "", "50.8", "", "2", "", "", "101", "1", "1", "8", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "80.9", "81.6", "", "", "", "", "81.5"]} +{"pcdb_id": 8880, "brand_name": "Glow-worm", "model_name": "BBU 54/4", "model_qualifier": "Black Beauty 4", "winter_efficiency_pct": 79.7, "summer_efficiency_pct": 69.6, "comparative_hot_water_efficiency_pct": 50.8, "output_kw_max": 15.83, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008880", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "BBU 54/4", "Black Beauty 4", "44 047 05", "2001", "current", "1", "4", "1", "1", "0", "", "", "1", "1", "1", "13.19", "15.83", "", "", "79.7", "69.6", "", "50.8", "", "2", "", "", "101", "1", "1", "8", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "80.9", "81.6", "", "", "", "", "81.5"]} +{"pcdb_id": 8881, "brand_name": "Glow-worm", "model_name": "BBU 54/4", "model_qualifier": "Heartbeat 4", "winter_efficiency_pct": 79.7, "summer_efficiency_pct": 69.6, "comparative_hot_water_efficiency_pct": 50.8, "output_kw_max": 15.83, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008881", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "BBU 54/4", "Heartbeat 4", "44 047 05", "2001", "current", "1", "4", "1", "1", "0", "", "", "1", "1", "1", "13.19", "15.83", "", "", "79.7", "69.6", "", "50.8", "", "2", "", "", "101", "1", "1", "8", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "80.9", "81.6", "", "", "", "", "81.5"]} +{"pcdb_id": 8882, "brand_name": "Glow-worm", "model_name": "BBU 54/4", "model_qualifier": "Chatsworth 4", "winter_efficiency_pct": 80.3, "summer_efficiency_pct": 70.2, "comparative_hot_water_efficiency_pct": 51.3, "output_kw_max": 14.21, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008882", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "BBU 54/4", "Chatsworth 4", "44 047 05", "2001", "current", "1", "4", "1", "1", "0", "", "", "1", "1", "1", "11.72", "14.21", "", "", "80.3", "70.2", "", "51.3", "", "2", "", "", "101", "1", "1", "8", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.9", "82.0", "", "", "", "", "82.0"]} +{"pcdb_id": 8883, "brand_name": "Glow-worm", "model_name": "BBU 54/4", "model_qualifier": "Dovedale 4", "winter_efficiency_pct": 80.3, "summer_efficiency_pct": 70.2, "comparative_hot_water_efficiency_pct": 51.3, "output_kw_max": 14.21, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008883", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "BBU 54/4", "Dovedale 4", "44 047 05", "2001", "current", "1", "4", "1", "1", "0", "", "", "1", "1", "1", "11.72", "14.21", "", "", "80.3", "70.2", "", "51.3", "", "2", "", "", "101", "1", "1", "8", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.9", "82.0", "", "", "", "", "82.0"]} +{"pcdb_id": 8884, "brand_name": "Glow-worm", "model_name": "BBU 45/4", "model_qualifier": "Miami 4", "winter_efficiency_pct": 79.3, "summer_efficiency_pct": 69.2, "comparative_hot_water_efficiency_pct": 50.5, "output_kw_max": 13.19, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008884", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "BBU 45/4", "Miami 4", "44 047 06", "2001", "current", "1", "4", "1", "1", "0", "", "", "1", "1", "1", "8.79", "13.19", "", "", "79.3", "69.2", "", "50.5", "", "2", "", "", "101", "1", "1", "8", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "80.8", "80.9", "", "", "", "", "80.9"]} +{"pcdb_id": 8885, "brand_name": "Glow-worm", "model_name": "BBU 45/4", "model_qualifier": "Firelite 4", "winter_efficiency_pct": 79.3, "summer_efficiency_pct": 69.2, "comparative_hot_water_efficiency_pct": 50.5, "output_kw_max": 13.19, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008885", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "BBU 45/4", "Firelite 4", "44 047 06", "2001", "current", "1", "4", "1", "1", "0", "", "", "1", "1", "1", "8.79", "13.19", "", "", "79.3", "69.2", "", "50.5", "", "2", "", "", "101", "1", "1", "8", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "80.8", "80.9", "", "", "", "", "80.9"]} +{"pcdb_id": 8886, "brand_name": "Glow-worm", "model_name": "BBU 45/4", "model_qualifier": "Contour 4", "winter_efficiency_pct": 79.3, "summer_efficiency_pct": 69.2, "comparative_hot_water_efficiency_pct": 50.5, "output_kw_max": 13.19, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008886", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "BBU 45/4", "Contour 4", "44 047 06", "2001", "current", "1", "4", "1", "1", "0", "", "", "1", "1", "1", "8.79", "13.19", "", "", "79.3", "69.2", "", "50.5", "", "2", "", "", "101", "1", "1", "8", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "80.8", "80.9", "", "", "", "", "80.9"]} +{"pcdb_id": 8887, "brand_name": "Glow-worm", "model_name": "BBU 45/4", "model_qualifier": "Black Beauty 4", "winter_efficiency_pct": 79.3, "summer_efficiency_pct": 69.2, "comparative_hot_water_efficiency_pct": 50.5, "output_kw_max": 13.19, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008887", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "BBU 45/4", "Black Beauty 4", "44 047 06", "2001", "current", "1", "4", "1", "1", "0", "", "", "1", "1", "1", "8.79", "13.19", "", "", "79.3", "69.2", "", "50.5", "", "2", "", "", "101", "1", "1", "8", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "80.8", "80.9", "", "", "", "", "80.9"]} +{"pcdb_id": 8888, "brand_name": "Glow-worm", "model_name": "BBU 45/4", "model_qualifier": "Heartbeat 4", "winter_efficiency_pct": 79.3, "summer_efficiency_pct": 69.2, "comparative_hot_water_efficiency_pct": 50.5, "output_kw_max": 13.19, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008888", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "BBU 45/4", "Heartbeat 4", "44 047 06", "2001", "current", "1", "4", "1", "1", "0", "", "", "1", "1", "1", "8.79", "13.19", "", "", "79.3", "69.2", "", "50.5", "", "2", "", "", "101", "1", "1", "8", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "80.8", "80.9", "", "", "", "", "80.9"]} +{"pcdb_id": 8889, "brand_name": "Glow-worm", "model_name": "BBU 45/4", "model_qualifier": "Chatsworth 4", "winter_efficiency_pct": 80.4, "summer_efficiency_pct": 70.3, "comparative_hot_water_efficiency_pct": 51.4, "output_kw_max": 11.72, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008889", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "BBU 45/4", "Chatsworth 4", "44 047 06", "2001", "current", "1", "4", "1", "1", "0", "", "", "1", "1", "1", "8.79", "11.72", "", "", "80.4", "70.3", "", "51.4", "", "2", "", "", "101", "1", "1", "8", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.5", "81.5", "", "", "", "", "81.7"]} +{"pcdb_id": 8890, "brand_name": "Glow-worm", "model_name": "BBU 45/4", "model_qualifier": "Dovedale 4", "winter_efficiency_pct": 80.4, "summer_efficiency_pct": 70.3, "comparative_hot_water_efficiency_pct": 51.4, "output_kw_max": 11.72, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008890", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "BBU 45/4", "Dovedale 4", "44 047 06", "2001", "current", "1", "4", "1", "1", "0", "", "", "1", "1", "1", "8.79", "11.72", "", "", "80.4", "70.3", "", "51.4", "", "2", "", "", "101", "1", "1", "8", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.5", "81.5", "", "", "", "", "81.7"]} +{"pcdb_id": 8891, "brand_name": "Worcester", "model_name": "Heatslave", "model_qualifier": "12/14-OSO-GB-L Oil Combi", "winter_efficiency_pct": 83.6, "summer_efficiency_pct": 75.5, "comparative_hot_water_efficiency_pct": 40.9, "output_kw_max": 14.0, "final_year_of_manufacture": 2008, "subsidiary_type": 0, "store_type": 1, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008891", "000035", "0", "2024/Jan/31 10:17", "Worcester Heat Systems", "Worcester", "Heatslave", "12/14-OSO-GB-L Oil Combi", "C16394/1", "2001", "2008", "4", "1", "1", "2", "0", "", "", "1", "1", "2", "12", "14", "", "", "83.6", "75.5", "", "40.9", "", "2", "", "", "203", "1", "1", "", "", "1", "1", "0", "46", "0", "25", "3", "80", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.4", "85.5", "", "", "", "", "85.5"]} +{"pcdb_id": 8892, "brand_name": "Worcester", "model_name": "Heatslave", "model_qualifier": "12/14-RSO-GB-L Oil Combi", "winter_efficiency_pct": 83.6, "summer_efficiency_pct": 75.5, "comparative_hot_water_efficiency_pct": 40.9, "output_kw_max": 14.0, "final_year_of_manufacture": 2008, "subsidiary_type": 0, "store_type": 1, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008892", "000035", "0", "2024/Jan/31 10:17", "Worcester Heat Systems", "Worcester", "Heatslave", "12/14-RSO-GB-L Oil Combi", "C16394/1", "2001", "2008", "4", "1", "1", "2", "0", "", "", "1", "2", "2", "12", "14", "", "", "83.6", "75.5", "", "40.9", "", "2", "", "", "203", "1", "1", "", "", "1", "1", "0", "46", "0", "25", "3", "80", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.4", "85.5", "", "", "", "", "85.5"]} +{"pcdb_id": 8893, "brand_name": "Worcester", "model_name": "Heatslave", "model_qualifier": "20/25-OSO-GB-L Oil Combi", "winter_efficiency_pct": 83.4, "summer_efficiency_pct": 75.3, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 25.0, "final_year_of_manufacture": 2008, "subsidiary_type": 0, "store_type": 1, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008893", "000035", "0", "2024/Jan/31 10:17", "Worcester Heat Systems", "Worcester", "Heatslave", "20/25-OSO-GB-L Oil Combi", "C16395/1", "2001", "2008", "4", "1", "1", "2", "0", "", "", "1", "1", "2", "20", "25", "", "", "83.4", "75.3", "", "40.8", "", "2", "", "", "203", "1", "1", "", "", "1", "1", "0", "46", "0", "25", "3", "80", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.3", "85.3", "", "", "", "", "85.3"]} +{"pcdb_id": 8894, "brand_name": "Worcester", "model_name": "Heatslave", "model_qualifier": "20/25-RSO-GB-L Oil Combi", "winter_efficiency_pct": 83.4, "summer_efficiency_pct": 75.3, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 25.0, "final_year_of_manufacture": 2008, "subsidiary_type": 0, "store_type": 1, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008894", "000035", "0", "2024/Jan/31 10:17", "Worcester Heat Systems", "Worcester", "Heatslave", "20/25-RSO-GB-L Oil Combi", "C16395/1", "2001", "2008", "4", "1", "1", "2", "0", "", "", "1", "2", "2", "20", "25", "", "", "83.4", "75.3", "", "40.8", "", "2", "", "", "203", "1", "1", "", "", "1", "1", "0", "46", "0", "25", "3", "80", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.3", "85.3", "", "", "", "", "85.3"]} +{"pcdb_id": 8895, "brand_name": "Worcester", "model_name": "Heatslave", "model_qualifier": "26/32-OSO-GB Oil Combi", "winter_efficiency_pct": 84.3, "summer_efficiency_pct": 76.2, "comparative_hot_water_efficiency_pct": 41.3, "output_kw_max": 32.0, "final_year_of_manufacture": 2008, "subsidiary_type": 0, "store_type": 1, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008895", "000035", "0", "2024/Jan/31 10:17", "Worcester Heat Systems", "Worcester", "Heatslave", "26/32-OSO-GB Oil Combi", "C14769/5", "2001", "2008", "4", "1", "1", "2", "0", "", "", "1", "1", "2", "26", "32", "", "", "84.3", "76.2", "", "41.3", "", "2", "", "", "203", "1", "1", "", "", "1", "1", "0", "46", "0", "25", "3", "80", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.3", "88.1", "", "", "", "", "87.5"]} +{"pcdb_id": 8896, "brand_name": "Worcester", "model_name": "Heatslave", "model_qualifier": "26/32-RSO-GB Oil Combi", "winter_efficiency_pct": 84.3, "summer_efficiency_pct": 76.2, "comparative_hot_water_efficiency_pct": 41.3, "output_kw_max": 32.0, "final_year_of_manufacture": 2008, "subsidiary_type": 0, "store_type": 1, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008896", "000035", "0", "2024/Jan/31 10:17", "Worcester Heat Systems", "Worcester", "Heatslave", "26/32-RSO-GB Oil Combi", "C14769/5", "2001", "2008", "4", "1", "1", "2", "0", "", "", "1", "2", "2", "26", "32", "", "", "84.3", "76.2", "", "41.3", "", "2", "", "", "203", "1", "1", "", "", "1", "1", "0", "46", "0", "25", "3", "80", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.3", "88.1", "", "", "", "", "87.5"]} +{"pcdb_id": 8897, "brand_name": "Ideal", "model_name": "Concord CXA", "model_qualifier": "40/H", "winter_efficiency_pct": 81.6, "summer_efficiency_pct": 71.5, "comparative_hot_water_efficiency_pct": 52.2, "output_kw_max": 43.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008897", "000008", "0", "2012/Mar/27 10:12", "Ideal Boilers", "Ideal", "Concord CXA", "40/H", "PI No. 87AP80", "2001", "current", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "43.5", "43.5", "", "", "81.6", "71.5", "", "52.2", "", "2", "", "", "101", "1", "1", "5", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "83.7", "83.5", "", "", "", "", "83.6"]} +{"pcdb_id": 8898, "brand_name": "Ideal", "model_name": "Concord CXA", "model_qualifier": "50/H", "winter_efficiency_pct": 81.6, "summer_efficiency_pct": 71.5, "comparative_hot_water_efficiency_pct": 52.2, "output_kw_max": 54.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008898", "000008", "0", "2012/Mar/27 10:12", "Ideal Boilers", "Ideal", "Concord CXA", "50/H", "PI No. 87AP80", "2001", "current", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "54.3", "54.3", "", "", "81.6", "71.5", "", "52.2", "", "2", "", "", "101", "1", "1", "5", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.7", "83.6", "", "", "", "", "83.4"]} +{"pcdb_id": 8899, "brand_name": "Ideal", "model_name": "Concord CXA", "model_qualifier": "60/H", "winter_efficiency_pct": 81.4, "summer_efficiency_pct": 71.3, "comparative_hot_water_efficiency_pct": 52.1, "output_kw_max": 65.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008899", "000008", "0", "2012/Mar/27 10:12", "Ideal Boilers", "Ideal", "Concord CXA", "60/H", "PI No. 87AP80", "2001", "current", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "65.2", "65.2", "", "", "81.4", "71.3", "", "52.1", "", "2", "", "", "101", "1", "1", "5", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.6", "83.4", "", "", "", "", "83.3"]} +{"pcdb_id": 8906, "brand_name": "Ideal", "model_name": "Concord CXS", "model_qualifier": "40/H", "winter_efficiency_pct": 81.4, "summer_efficiency_pct": 70.7, "comparative_hot_water_efficiency_pct": 51.6, "output_kw_max": 43.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008906", "000008", "0", "2012/Mar/27 10:12", "Ideal Boilers", "Ideal", "Concord CXS", "40/H", "PI No. 87AQ103", "2001", "current", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "43.5", "43.5", "", "", "81.4", "70.7", "", "51.6", "", "2", "", "", "102", "1", "2", "10", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "83.7", "81.9", "", "", "", "", "82.2"]} +{"pcdb_id": 8907, "brand_name": "Ideal", "model_name": "Concord CXS", "model_qualifier": "50/H", "winter_efficiency_pct": 81.1, "summer_efficiency_pct": 70.4, "comparative_hot_water_efficiency_pct": 51.4, "output_kw_max": 54.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008907", "000008", "0", "2012/Mar/27 10:12", "Ideal Boilers", "Ideal", "Concord CXS", "50/H", "PI No. 87AQ103", "2001", "current", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "54.3", "54.3", "", "", "81.1", "70.4", "", "51.4", "", "2", "", "", "102", "1", "2", "10", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.7", "81.5", "", "", "", "", "81.8"]} +{"pcdb_id": 8908, "brand_name": "Ideal", "model_name": "Concord CXS", "model_qualifier": "60/H", "winter_efficiency_pct": 81.7, "summer_efficiency_pct": 71.0, "comparative_hot_water_efficiency_pct": 51.8, "output_kw_max": 65.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008908", "000008", "0", "2012/Mar/27 10:12", "Ideal Boilers", "Ideal", "Concord CXS", "60/H", "PI No. 87AQ103", "2001", "current", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "65.2", "65.2", "", "", "81.7", "71.0", "", "51.8", "", "2", "", "", "102", "1", "2", "10", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.6", "82.7", "", "", "", "", "82.7"]} +{"pcdb_id": 8915, "brand_name": "Ideal", "model_name": "Concord CXSD", "model_qualifier": "40/H", "winter_efficiency_pct": 81.4, "summer_efficiency_pct": 70.7, "comparative_hot_water_efficiency_pct": 51.6, "output_kw_max": 43.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008915", "000008", "0", "2012/Mar/27 10:12", "Ideal Boilers", "Ideal", "Concord CXSD", "40/H", "PI No. 87AQ103", "2001", "current", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "43.5", "43.5", "", "", "81.4", "70.7", "", "51.6", "", "2", "", "", "102", "1", "2", "10", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "83.7", "81.9", "", "", "", "", "82.2"]} +{"pcdb_id": 8916, "brand_name": "Ideal", "model_name": "Concord CXSD", "model_qualifier": "50/H", "winter_efficiency_pct": 81.1, "summer_efficiency_pct": 70.4, "comparative_hot_water_efficiency_pct": 51.4, "output_kw_max": 54.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008916", "000008", "0", "2012/Mar/27 10:12", "Ideal Boilers", "Ideal", "Concord CXSD", "50/H", "PI No. 87AQ103", "2001", "current", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "54.3", "54.3", "", "", "81.1", "70.4", "", "51.4", "", "2", "", "", "102", "1", "2", "10", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.7", "81.5", "", "", "", "", "81.8"]} +{"pcdb_id": 8917, "brand_name": "Ideal", "model_name": "Concord CXSD", "model_qualifier": "60/H", "winter_efficiency_pct": 81.7, "summer_efficiency_pct": 71.0, "comparative_hot_water_efficiency_pct": 51.8, "output_kw_max": 65.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008917", "000008", "0", "2012/Mar/27 10:12", "Ideal Boilers", "Ideal", "Concord CXSD", "60/H", "PI No. 87AQ103", "2001", "current", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "65.2", "65.2", "", "", "81.7", "71.0", "", "51.8", "", "2", "", "", "102", "1", "2", "10", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.6", "82.7", "", "", "", "", "82.7"]} +{"pcdb_id": 8924, "brand_name": "HRM Boilers", "model_name": "Wallstar 15/20", "model_qualifier": "12", "winter_efficiency_pct": 86.4, "summer_efficiency_pct": 74.7, "comparative_hot_water_efficiency_pct": 54.6, "output_kw_max": 20.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008924", "000098", "0", "2012/Mar/27 10:12", "HRM Boilers", "HRM Boilers", "Wallstar 15/20", "12", "10021108", "2002", "current", "4", "2", "1", "1", "0", "", "", "1", "2", "2", "15", "20", "", "", "86.4", "74.7", "", "54.6", "", "2", "", "", "201", "1", "1", "140", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.6", "86.6", "", "", "", "", "86.6"]} +{"pcdb_id": 8925, "brand_name": "Warmflow", "model_name": "Bluebird", "model_qualifier": "50/70 BB", "winter_efficiency_pct": 85.2, "summer_efficiency_pct": 73.5, "comparative_hot_water_efficiency_pct": 53.7, "output_kw_max": 20.52, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008925", "000063", "0", "2012/Mar/27 10:12", "Warmflow Engineering", "Warmflow", "Bluebird", "50/70 BB", "", "2000", "current", "4", "1", "2", "1", "0", "", "", "1", "2", "2", "14.65", "20.52", "", "", "85.2", "73.5", "", "53.7", "", "2", "", "", "201", "1", "1", "90", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "84.9", "85.5", "", "", "", "", "85.3"]} +{"pcdb_id": 8926, "brand_name": "Warmflow", "model_name": "Whitebird", "model_qualifier": "50/70 WB", "winter_efficiency_pct": 85.2, "summer_efficiency_pct": 73.5, "comparative_hot_water_efficiency_pct": 53.7, "output_kw_max": 20.52, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008926", "000063", "0", "2012/Mar/27 10:12", "Warmflow Engineering", "Warmflow", "Whitebird", "50/70 WB", "", "2000", "current", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "14.65", "20.52", "", "", "85.2", "73.5", "", "53.7", "", "2", "", "", "201", "1", "1", "90", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "84.9", "85.5", "", "", "", "", "85.3"]} +{"pcdb_id": 8927, "brand_name": "Warmflow", "model_name": "Goldbird", "model_qualifier": "50/70 GB", "winter_efficiency_pct": 85.2, "summer_efficiency_pct": 73.5, "comparative_hot_water_efficiency_pct": 53.7, "output_kw_max": 20.51, "final_year_of_manufacture": 2006, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008927", "000063", "0", "2012/Mar/27 10:12", "Warmflow Engineering", "Warmflow", "Goldbird", "50/70 GB", "", "2000", "2006", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "14.65", "20.51", "", "", "85.2", "73.5", "", "53.7", "", "2", "", "", "201", "1", "1", "90", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "84.9", "85.5", "", "", "", "", "85.3"]} +{"pcdb_id": 8928, "brand_name": "Warmflow", "model_name": "Kabin Pak", "model_qualifier": "50/70 KP", "winter_efficiency_pct": 85.2, "summer_efficiency_pct": 73.5, "comparative_hot_water_efficiency_pct": 53.7, "output_kw_max": 20.52, "final_year_of_manufacture": 2007, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008928", "000063", "0", "2012/Mar/27 10:12", "Warmflow Engineering", "Warmflow", "Kabin Pak", "50/70 KP", "", "2000", "2007", "4", "1", "2", "1", "0", "", "", "1", "2", "2", "14.65", "20.52", "", "", "85.2", "73.5", "", "53.7", "", "2", "", "", "201", "1", "1", "90", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "84.9", "85.5", "", "", "", "", "85.3"]} +{"pcdb_id": 8929, "brand_name": "Warmflow", "model_name": "System Whitebird", "model_qualifier": "50/70 SWB", "winter_efficiency_pct": 85.2, "summer_efficiency_pct": 73.5, "comparative_hot_water_efficiency_pct": 53.7, "output_kw_max": 20.52, "final_year_of_manufacture": 2006, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008929", "000063", "0", "2012/Mar/27 10:12", "Warmflow Engineering", "Warmflow", "System Whitebird", "50/70 SWB", "", "2001", "2006", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "14.65", "20.52", "", "", "85.2", "73.5", "", "53.7", "", "2", "", "", "201", "1", "1", "90", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "84.9", "85.5", "", "", "", "", "85.3"]} +{"pcdb_id": 8930, "brand_name": "Warmflow", "model_name": "Bluebird", "model_qualifier": "70/90 BB", "winter_efficiency_pct": 85.8, "summer_efficiency_pct": 74.1, "comparative_hot_water_efficiency_pct": 54.1, "output_kw_max": 26.38, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008930", "000063", "0", "2012/Mar/27 10:12", "Warmflow Engineering", "Warmflow", "Bluebird", "70/90 BB", "", "2000", "current", "4", "1", "2", "1", "0", "", "", "1", "2", "2", "20.52", "26.38", "", "", "85.8", "74.1", "", "54.1", "", "2", "", "", "201", "1", "1", "90", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "84.8", "86.8", "", "", "", "", "86.4"]} +{"pcdb_id": 8931, "brand_name": "Warmflow", "model_name": "Whitebird", "model_qualifier": "70/90 WB", "winter_efficiency_pct": 85.8, "summer_efficiency_pct": 74.1, "comparative_hot_water_efficiency_pct": 54.1, "output_kw_max": 26.38, "final_year_of_manufacture": 2006, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008931", "000063", "0", "2012/Mar/27 10:12", "Warmflow Engineering", "Warmflow", "Whitebird", "70/90 WB", "", "2000", "2006", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "20.52", "26.38", "", "", "85.8", "74.1", "", "54.1", "", "2", "", "", "201", "1", "1", "90", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "84.8", "86.8", "", "", "", "", "86.4"]} +{"pcdb_id": 8932, "brand_name": "Warmflow", "model_name": "Goldbird", "model_qualifier": "70/90 GB", "winter_efficiency_pct": 85.8, "summer_efficiency_pct": 74.1, "comparative_hot_water_efficiency_pct": 54.1, "output_kw_max": 26.37, "final_year_of_manufacture": 2006, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008932", "000063", "0", "2012/Mar/27 10:12", "Warmflow Engineering", "Warmflow", "Goldbird", "70/90 GB", "", "2000", "2006", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "20.51", "26.37", "", "", "85.8", "74.1", "", "54.1", "", "2", "", "", "201", "1", "1", "90", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "84.8", "86.8", "", "", "", "", "86.4"]} +{"pcdb_id": 8933, "brand_name": "Warmflow", "model_name": "Kabin Pak", "model_qualifier": "70/90 KP", "winter_efficiency_pct": 85.8, "summer_efficiency_pct": 74.1, "comparative_hot_water_efficiency_pct": 54.1, "output_kw_max": 26.38, "final_year_of_manufacture": 2007, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008933", "000063", "0", "2012/Mar/27 10:12", "Warmflow Engineering", "Warmflow", "Kabin Pak", "70/90 KP", "", "2000", "2007", "4", "1", "2", "1", "0", "", "", "1", "2", "2", "20.52", "26.38", "", "", "85.8", "74.1", "", "54.1", "", "2", "", "", "201", "1", "1", "90", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "84.8", "86.8", "", "", "", "", "86.4"]} +{"pcdb_id": 8934, "brand_name": "Warmflow", "model_name": "System Whitebird", "model_qualifier": "70/90 SWB", "winter_efficiency_pct": 85.8, "summer_efficiency_pct": 74.1, "comparative_hot_water_efficiency_pct": 54.1, "output_kw_max": 26.38, "final_year_of_manufacture": 2006, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008934", "000063", "0", "2012/Mar/27 10:12", "Warmflow Engineering", "Warmflow", "System Whitebird", "70/90 SWB", "", "2001", "2006", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "20.52", "26.38", "", "", "85.8", "74.1", "", "54.1", "", "2", "", "", "201", "1", "1", "90", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "84.8", "86.8", "", "", "", "", "86.4"]} +{"pcdb_id": 8935, "brand_name": "Warmflow", "model_name": "Combi", "model_qualifier": "70/90 Combi", "winter_efficiency_pct": 83.9, "summer_efficiency_pct": 75.8, "comparative_hot_water_efficiency_pct": 40.9, "output_kw_max": 26.38, "final_year_of_manufacture": 2007, "subsidiary_type": 0, "store_type": 1, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008935", "000063", "0", "2024/Jan/31 10:17", "Warmflow Engineering", "Warmflow", "Combi", "70/90 Combi", "", "2001", "2007", "4", "1", "1", "2", "0", "", "", "1", "2", "2", "20.52", "26.38", "", "", "83.9", "75.8", "", "40.9", "", "2", "", "", "203", "1", "1", "90", "0", "1", "1", "0", "50", "0", "25", "3", "80", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "84.8", "86.8", "", "", "", "", "86.4"]} +{"pcdb_id": 8936, "brand_name": "Warmflow", "model_name": "Bluebird", "model_qualifier": "90/120 BB", "winter_efficiency_pct": 86.2, "summer_efficiency_pct": 74.5, "comparative_hot_water_efficiency_pct": 54.4, "output_kw_max": 35.17, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008936", "000063", "0", "2012/Mar/27 10:12", "Warmflow Engineering", "Warmflow", "Bluebird", "90/120 BB", "", "2000", "current", "4", "1", "2", "1", "0", "", "", "1", "2", "2", "26.38", "35.17", "", "", "86.2", "74.5", "", "54.4", "", "2", "", "", "201", "1", "1", "90", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.0", "86.4", "", "", "", "", "86.3"]} +{"pcdb_id": 8937, "brand_name": "Warmflow", "model_name": "Whitebird", "model_qualifier": "90/120 WB", "winter_efficiency_pct": 86.2, "summer_efficiency_pct": 74.5, "comparative_hot_water_efficiency_pct": 54.4, "output_kw_max": 35.17, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008937", "000063", "0", "2012/Mar/27 10:12", "Warmflow Engineering", "Warmflow", "Whitebird", "90/120 WB", "", "2000", "current", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "26.38", "35.17", "", "", "86.2", "74.5", "", "54.4", "", "2", "", "", "201", "1", "1", "90", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.0", "86.4", "", "", "", "", "86.3"]} +{"pcdb_id": 8938, "brand_name": "Warmflow", "model_name": "Goldbird", "model_qualifier": "90/120 GB", "winter_efficiency_pct": 86.2, "summer_efficiency_pct": 74.5, "comparative_hot_water_efficiency_pct": 54.4, "output_kw_max": 35.16, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008938", "000063", "0", "2012/Mar/27 10:12", "Warmflow Engineering", "Warmflow", "Goldbird", "90/120 GB", "", "2000", "current", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "26.37", "35.16", "", "", "86.2", "74.5", "", "54.4", "", "2", "", "", "201", "1", "1", "90", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.0", "86.4", "", "", "", "", "86.3"]} +{"pcdb_id": 8939, "brand_name": "Warmflow", "model_name": "Kabin Pak", "model_qualifier": "90/120 KP", "winter_efficiency_pct": 86.2, "summer_efficiency_pct": 74.5, "comparative_hot_water_efficiency_pct": 54.4, "output_kw_max": 35.17, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008939", "000063", "0", "2012/Mar/27 10:12", "Warmflow Engineering", "Warmflow", "Kabin Pak", "90/120 KP", "", "2000", "current", "4", "1", "2", "1", "0", "", "", "1", "2", "2", "26.38", "35.17", "", "", "86.2", "74.5", "", "54.4", "", "2", "", "", "201", "1", "1", "90", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.0", "86.4", "", "", "", "", "86.3"]} +{"pcdb_id": 8940, "brand_name": "Warmflow", "model_name": "Bluebird", "model_qualifier": "120/150 BB", "winter_efficiency_pct": 86.5, "summer_efficiency_pct": 74.8, "comparative_hot_water_efficiency_pct": 54.7, "output_kw_max": 44.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008940", "000063", "0", "2012/Mar/27 10:12", "Warmflow Engineering", "Warmflow", "Bluebird", "120/150 BB", "", "1996", "current", "4", "1", "2", "1", "0", "", "", "1", "2", "2", "35.17", "44.0", "", "", "86.5", "74.8", "", "54.7", "", "2", "", "", "201", "1", "1", "90", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.9", "88.0", "", "", "", "", "87.6"]} +{"pcdb_id": 8941, "brand_name": "Warmflow", "model_name": "Goldbird", "model_qualifier": "120/150 GB", "winter_efficiency_pct": 86.5, "summer_efficiency_pct": 74.8, "comparative_hot_water_efficiency_pct": 54.7, "output_kw_max": 44.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008941", "000063", "0", "2012/Mar/27 10:12", "Warmflow Engineering", "Warmflow", "Goldbird", "120/150 GB", "", "1996", "current", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "35.17", "44.0", "", "", "86.5", "74.8", "", "54.7", "", "2", "", "", "201", "1", "1", "90", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.9", "88.0", "", "", "", "", "87.6"]} +{"pcdb_id": 8942, "brand_name": "Warmflow", "model_name": "Whitebird", "model_qualifier": "120/150 WB", "winter_efficiency_pct": 86.5, "summer_efficiency_pct": 74.8, "comparative_hot_water_efficiency_pct": 54.7, "output_kw_max": 44.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008942", "000063", "0", "2012/Mar/27 10:12", "Warmflow Engineering", "Warmflow", "Whitebird", "120/150 WB", "", "1996", "current", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "35.17", "44.0", "", "", "86.5", "74.8", "", "54.7", "", "2", "", "", "201", "1", "1", "90", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.9", "88.0", "", "", "", "", "87.6"]} +{"pcdb_id": 8943, "brand_name": "Firebird", "model_name": "Popular", "model_qualifier": "120-150", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 43.96, "final_year_of_manufacture": 2013, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008943", "000047", "0", "2018/Jan/03 11:58", "Firebird Boilers", "Firebird", "Popular", "120-150", "", "", "2013", "4", "1", "1", "1", "0", "", "", "1", "2", "1", "35.17", "43.96", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.3", "87.2", "", "", "", "", "87.1"]} +{"pcdb_id": 8944, "brand_name": "Firebird", "model_name": "Heatpac", "model_qualifier": "120-150", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 43.96, "final_year_of_manufacture": 2013, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008944", "000047", "0", "2018/Jan/03 11:59", "Firebird Boilers", "Firebird", "Heatpac", "120-150", "", "", "2013", "4", "1", "2", "1", "0", "", "", "1", "1", "1", "35.17", "43.96", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.3", "87.2", "", "", "", "", "87.1"]} +{"pcdb_id": 8945, "brand_name": "Firebird", "model_name": "Boilerhouse S", "model_qualifier": "120-150", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 43.96, "final_year_of_manufacture": 2013, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008945", "000047", "0", "2018/Jan/03 12:01", "Firebird Boilers", "Firebird", "Boilerhouse S", "120-150", "", "", "2013", "4", "1", "1", "1", "0", "", "", "1", "2", "1", "35.17", "43.96", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.3", "87.2", "", "", "", "", "87.1"]} +{"pcdb_id": 8946, "brand_name": "Firebird", "model_name": "Roomsealed Popular (Hideaway)", "model_qualifier": "120-150", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 43.96, "final_year_of_manufacture": 2010, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008946", "000047", "0", "2012/Mar/27 10:12", "Firebird Boilers", "Firebird", "Roomsealed Popular (Hideaway)", "120-150", "", "", "2010", "4", "1", "1", "1", "0", "", "", "1", "2", "1", "35.17", "43.96", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.3", "87.2", "", "", "", "", "87.1"]} +{"pcdb_id": 8947, "brand_name": "Firebird", "model_name": "S (White Cased)", "model_qualifier": "120-150", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 43.96, "final_year_of_manufacture": 2013, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008947", "000047", "0", "2018/Jan/03 12:03", "Firebird Boilers", "Firebird", "S (White Cased)", "120-150", "", "", "2013", "4", "1", "1", "1", "0", "", "", "1", "2", "1", "35.17", "43.96", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.3", "87.2", "", "", "", "", "87.1"]} +{"pcdb_id": 8948, "brand_name": "Hepworth Heating", "model_name": "Halstead Buckingham 4 40BFF", "model_qualifier": "", "winter_efficiency_pct": 79.2, "summer_efficiency_pct": 69.1, "comparative_hot_water_efficiency_pct": 50.5, "output_kw_max": 11.72, "final_year_of_manufacture": 2006, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008948", "000019", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Hepworth Heating", "Halstead Buckingham 4 40BFF", "", "41-333-88", "2002", "2006", "1", "1", "1", "1", "0", "", "", "1", "2", "2", "11.72", "11.72", "", "", "79.2", "69.1", "", "50.5", "", "2", "", "", "101", "1", "1", "37", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.7", "79.8", "", "", "", "", "80.2"]} +{"pcdb_id": 8949, "brand_name": "Hepworth Heating", "model_name": "Halstead Buckingham 4 40CFF", "model_qualifier": "", "winter_efficiency_pct": 79.2, "summer_efficiency_pct": 69.1, "comparative_hot_water_efficiency_pct": 50.5, "output_kw_max": 11.72, "final_year_of_manufacture": 2006, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008949", "000019", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Hepworth Heating", "Halstead Buckingham 4 40CFF", "", "41-333-94", "2002", "2006", "1", "1", "1", "1", "0", "", "", "1", "2", "2", "11.72", "11.72", "", "", "79.2", "69.1", "", "50.5", "", "2", "", "", "101", "1", "1", "37", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.7", "79.8", "", "", "", "", "80.2"]} +{"pcdb_id": 8950, "brand_name": "Hepworth Heating", "model_name": "Halstead Buckingham 4 50BFF", "model_qualifier": "", "winter_efficiency_pct": 79.1, "summer_efficiency_pct": 69.0, "comparative_hot_water_efficiency_pct": 50.4, "output_kw_max": 14.65, "final_year_of_manufacture": 2006, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008950", "000019", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Hepworth Heating", "Halstead Buckingham 4 50BFF", "", "41-333-89", "2002", "2006", "1", "1", "1", "1", "0", "", "", "1", "2", "2", "14.65", "14.65", "", "", "79.1", "69.0", "", "50.4", "", "2", "", "", "101", "1", "1", "37", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.6", "79.7", "", "", "", "", "80.1"]} +{"pcdb_id": 8951, "brand_name": "Hepworth Heating", "model_name": "Halstead Buckingham 4 50CFF", "model_qualifier": "", "winter_efficiency_pct": 79.1, "summer_efficiency_pct": 69.0, "comparative_hot_water_efficiency_pct": 50.4, "output_kw_max": 14.65, "final_year_of_manufacture": 2006, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008951", "000019", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Hepworth Heating", "Halstead Buckingham 4 50CFF", "", "41-333-95", "2002", "2006", "1", "1", "1", "1", "0", "", "", "1", "1", "2", "14.65", "14.65", "", "", "79.1", "69.0", "", "50.4", "", "2", "", "", "101", "1", "1", "37", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.6", "79.7", "", "", "", "", "80.1"]} +{"pcdb_id": 8952, "brand_name": "Hepworth Heating", "model_name": "Halstead Buckingham 4 60CFF", "model_qualifier": "", "winter_efficiency_pct": 79.4, "summer_efficiency_pct": 69.3, "comparative_hot_water_efficiency_pct": 50.6, "output_kw_max": 17.0, "final_year_of_manufacture": 2006, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008952", "000019", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Hepworth Heating", "Halstead Buckingham 4 60CFF", "", "41-333-96", "2002", "2006", "1", "1", "1", "1", "0", "", "", "1", "1", "2", "17", "17", "", "", "79.4", "69.3", "", "50.6", "", "2", "", "", "101", "1", "1", "37", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.5", "80.4", "", "", "", "", "80.6"]} +{"pcdb_id": 8953, "brand_name": "Hepworth Heating", "model_name": "Halstead Buckingham 4 60BFF", "model_qualifier": "", "winter_efficiency_pct": 79.4, "summer_efficiency_pct": 69.3, "comparative_hot_water_efficiency_pct": 50.6, "output_kw_max": 17.0, "final_year_of_manufacture": 2006, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008953", "000019", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Hepworth Heating", "Halstead Buckingham 4 60BFF", "", "41-333-90", "2002", "2006", "1", "1", "1", "1", "0", "", "", "1", "2", "2", "17", "17", "", "", "79.4", "69.3", "", "50.6", "", "2", "", "", "101", "1", "1", "37", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.5", "80.4", "", "", "", "", "80.6"]} +{"pcdb_id": 8954, "brand_name": "Hepworth Heating", "model_name": "Halstead Buckingham 4 80CFF", "model_qualifier": "", "winter_efficiency_pct": 79.3, "summer_efficiency_pct": 69.2, "comparative_hot_water_efficiency_pct": 50.6, "output_kw_max": 23.45, "final_year_of_manufacture": 2006, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008954", "000019", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Hepworth Heating", "Halstead Buckingham 4 80CFF", "", "41-333-97", "2002", "2006", "1", "1", "1", "1", "0", "", "", "1", "1", "2", "23.45", "23.45", "", "", "79.3", "69.2", "", "50.6", "", "2", "", "", "101", "1", "1", "49", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.5", "80.4", "", "", "", "", "80.6"]} +{"pcdb_id": 8955, "brand_name": "Hepworth Heating", "model_name": "Halstead Buckingham 4 80BFF", "model_qualifier": "", "winter_efficiency_pct": 79.3, "summer_efficiency_pct": 69.2, "comparative_hot_water_efficiency_pct": 50.6, "output_kw_max": 23.45, "final_year_of_manufacture": 2006, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008955", "000019", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Hepworth Heating", "Halstead Buckingham 4 80BFF", "", "41-333-91", "2002", "2006", "1", "1", "1", "1", "0", "", "", "1", "2", "2", "23.45", "23.45", "", "", "79.3", "69.2", "", "50.6", "", "2", "", "", "101", "1", "1", "49", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.5", "80.4", "", "", "", "", "80.6"]} +{"pcdb_id": 8956, "brand_name": "Hepworth Heating", "model_name": "Halstead Buckingham 4 100CFF", "model_qualifier": "", "winter_efficiency_pct": 81.2, "summer_efficiency_pct": 71.1, "comparative_hot_water_efficiency_pct": 51.9, "output_kw_max": 29.31, "final_year_of_manufacture": 2006, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008956", "000019", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Hepworth Heating", "Halstead Buckingham 4 100CFF", "", "41-333-98", "2002", "2006", "1", "1", "1", "1", "0", "", "", "1", "1", "2", "29.31", "29.31", "", "", "81.2", "71.1", "", "51.9", "", "2", "", "", "101", "1", "1", "49", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "83.6", "82.7", "", "", "", "", "82.9"]} +{"pcdb_id": 8957, "brand_name": "Hepworth Heating", "model_name": "Halstead Buckingham 4 100BFF", "model_qualifier": "", "winter_efficiency_pct": 81.2, "summer_efficiency_pct": 71.1, "comparative_hot_water_efficiency_pct": 51.9, "output_kw_max": 29.31, "final_year_of_manufacture": 2006, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008957", "000019", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Hepworth Heating", "Halstead Buckingham 4 100BFF", "", "41-333-92", "2002", "2006", "1", "1", "1", "1", "0", "", "", "1", "2", "2", "29.31", "29.31", "", "", "81.2", "71.1", "", "51.9", "", "2", "", "", "101", "1", "1", "49", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "83.6", "82.7", "", "", "", "", "82.9"]} +{"pcdb_id": 8958, "brand_name": "Hepworth Heating", "model_name": "Halstead Buckingham 4 115CFF", "model_qualifier": "", "winter_efficiency_pct": 79.6, "summer_efficiency_pct": 69.5, "comparative_hot_water_efficiency_pct": 50.8, "output_kw_max": 33.7, "final_year_of_manufacture": 2006, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008958", "000019", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Hepworth Heating", "Halstead Buckingham 4 115CFF", "", "41-333-99", "2002", "2006", "1", "1", "1", "1", "0", "", "", "1", "1", "2", "33.7", "33.7", "", "", "79.6", "69.5", "", "50.8", "", "2", "", "", "101", "1", "1", "49", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.5", "80.9", "", "", "", "", "81.0"]} +{"pcdb_id": 8959, "brand_name": "Hepworth Heating", "model_name": "Halstead Buckingham 4 115BFF", "model_qualifier": "", "winter_efficiency_pct": 79.6, "summer_efficiency_pct": 69.5, "comparative_hot_water_efficiency_pct": 50.8, "output_kw_max": 33.7, "final_year_of_manufacture": 2006, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008959", "000019", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Hepworth Heating", "Halstead Buckingham 4 115BFF", "", "41-333-93", "2002", "2006", "1", "1", "1", "1", "0", "", "", "1", "2", "2", "33.7", "33.7", "", "", "79.6", "69.5", "", "50.8", "", "2", "", "", "101", "1", "1", "49", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.5", "80.9", "", "", "", "", "81.0"]} +{"pcdb_id": 8960, "brand_name": "Glow-worm", "model_name": "Hideaway 40BFF", "model_qualifier": "", "winter_efficiency_pct": 79.2, "summer_efficiency_pct": 69.1, "comparative_hot_water_efficiency_pct": 50.5, "output_kw_max": 11.72, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008960", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Hideaway 40BFF", "", "41 047 32", "2002", "current", "1", "1", "1", "1", "0", "", "", "1", "2", "2", "11.72", "11.72", "", "", "79.2", "69.1", "", "50.5", "", "2", "", "", "101", "1", "1", "37", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.7", "79.8", "", "", "", "", "80.2"]} +{"pcdb_id": 8961, "brand_name": "Glow-worm", "model_name": "Hideaway 40CFF", "model_qualifier": "", "winter_efficiency_pct": 79.2, "summer_efficiency_pct": 69.1, "comparative_hot_water_efficiency_pct": 50.5, "output_kw_max": 11.72, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008961", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Hideaway 40CFF", "", "41 047 32", "2002", "current", "1", "1", "1", "1", "0", "", "", "1", "2", "2", "11.72", "11.72", "", "", "79.2", "69.1", "", "50.5", "", "2", "", "", "101", "1", "1", "37", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.7", "79.8", "", "", "", "", "80.2"]} +{"pcdb_id": 8962, "brand_name": "Glow-worm", "model_name": "Hideaway 50BFF", "model_qualifier": "", "winter_efficiency_pct": 79.1, "summer_efficiency_pct": 69.0, "comparative_hot_water_efficiency_pct": 50.4, "output_kw_max": 14.65, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008962", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Hideaway 50BFF", "", "41 047 33", "2002", "current", "1", "1", "1", "1", "0", "", "", "1", "2", "2", "14.65", "14.65", "", "", "79.1", "69.0", "", "50.4", "", "2", "", "", "101", "1", "1", "37", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.6", "79.7", "", "", "", "", "80.1"]} +{"pcdb_id": 8963, "brand_name": "Glow-worm", "model_name": "Hideaway 50CFF", "model_qualifier": "", "winter_efficiency_pct": 79.1, "summer_efficiency_pct": 69.0, "comparative_hot_water_efficiency_pct": 50.4, "output_kw_max": 14.65, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008963", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Hideaway 50CFF", "", "41 047 39", "2002", "current", "1", "1", "1", "1", "0", "", "", "1", "1", "2", "14.65", "14.65", "", "", "79.1", "69.0", "", "50.4", "", "2", "", "", "101", "1", "1", "37", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.6", "79.7", "", "", "", "", "80.1"]} +{"pcdb_id": 8964, "brand_name": "Glow-worm", "model_name": "Hideaway 60CFF", "model_qualifier": "", "winter_efficiency_pct": 79.4, "summer_efficiency_pct": 69.3, "comparative_hot_water_efficiency_pct": 50.6, "output_kw_max": 17.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008964", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Hideaway 60CFF", "", "41 047 40", "2002", "current", "1", "1", "1", "1", "0", "", "", "1", "1", "2", "17", "17", "", "", "79.4", "69.3", "", "50.6", "", "2", "", "", "101", "1", "1", "37", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.5", "80.4", "", "", "", "", "80.6"]} +{"pcdb_id": 8965, "brand_name": "Glow-worm", "model_name": "Hideaway 60BFF", "model_qualifier": "", "winter_efficiency_pct": 79.4, "summer_efficiency_pct": 69.3, "comparative_hot_water_efficiency_pct": 50.6, "output_kw_max": 17.0, "final_year_of_manufacture": 2006, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008965", "000207", "0", "2018/Oct/15 12:00", "Hepworth Heating", "Glow-worm", "Hideaway 60BFF", "", "41 047 34", "2002", "2006", "1", "1", "1", "1", "0", "", "", "1", "2", "2", "17", "17", "", "", "79.4", "69.3", "", "50.6", "", "2", "", "", "101", "1", "1", "37", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.5", "80.4", "", "", "", "", "80.6"]} +{"pcdb_id": 8966, "brand_name": "Glow-worm", "model_name": "Hideaway 80CFF", "model_qualifier": "", "winter_efficiency_pct": 79.3, "summer_efficiency_pct": 69.2, "comparative_hot_water_efficiency_pct": 50.6, "output_kw_max": 23.45, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008966", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Hideaway 80CFF", "", "41 047 41", "2002", "current", "1", "1", "1", "1", "0", "", "", "1", "1", "2", "23.45", "23.45", "", "", "79.3", "69.2", "", "50.6", "", "2", "", "", "101", "1", "1", "49", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.5", "80.4", "", "", "", "", "80.6"]} +{"pcdb_id": 8967, "brand_name": "Glow-worm", "model_name": "Hideaway 80BFF", "model_qualifier": "", "winter_efficiency_pct": 79.3, "summer_efficiency_pct": 69.2, "comparative_hot_water_efficiency_pct": 50.6, "output_kw_max": 23.45, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008967", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Hideaway 80BFF", "", "41 047 35", "2002", "current", "1", "1", "1", "1", "0", "", "", "1", "2", "2", "23.45", "23.45", "", "", "79.3", "69.2", "", "50.6", "", "2", "", "", "101", "1", "1", "49", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.5", "80.4", "", "", "", "", "80.6"]} +{"pcdb_id": 8968, "brand_name": "Glow-worm", "model_name": "Hideaway 100CFF", "model_qualifier": "", "winter_efficiency_pct": 81.2, "summer_efficiency_pct": 71.1, "comparative_hot_water_efficiency_pct": 51.9, "output_kw_max": 29.31, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008968", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Hideaway 100CFF", "", "41 047 42", "2002", "current", "1", "1", "1", "1", "0", "", "", "1", "1", "2", "29.31", "29.31", "", "", "81.2", "71.1", "", "51.9", "", "2", "", "", "101", "1", "1", "49", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "83.6", "82.7", "", "", "", "", "82.9"]} +{"pcdb_id": 8969, "brand_name": "Glow-worm", "model_name": "Hideaway 100BFF", "model_qualifier": "", "winter_efficiency_pct": 81.2, "summer_efficiency_pct": 71.1, "comparative_hot_water_efficiency_pct": 51.9, "output_kw_max": 29.31, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008969", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Hideaway 100BFF", "", "41 047 36", "2002", "current", "1", "1", "1", "1", "0", "", "", "1", "2", "2", "29.31", "29.31", "", "", "81.2", "71.1", "", "51.9", "", "2", "", "", "101", "1", "1", "49", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "83.6", "82.7", "", "", "", "", "82.9"]} +{"pcdb_id": 8970, "brand_name": "Glow-worm", "model_name": "Hideaway 115CFF", "model_qualifier": "", "winter_efficiency_pct": 79.6, "summer_efficiency_pct": 69.5, "comparative_hot_water_efficiency_pct": 50.8, "output_kw_max": 33.7, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008970", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Hideaway 115CFF", "", "41 047 43", "2002", "current", "1", "1", "1", "1", "0", "", "", "1", "1", "2", "33.7", "33.7", "", "", "79.6", "69.5", "", "50.8", "", "2", "", "", "101", "1", "1", "49", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.5", "80.9", "", "", "", "", "81.0"]} +{"pcdb_id": 8971, "brand_name": "Glow-worm", "model_name": "Hideaway 115BFF", "model_qualifier": "", "winter_efficiency_pct": 79.6, "summer_efficiency_pct": 69.5, "comparative_hot_water_efficiency_pct": 50.8, "output_kw_max": 33.7, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008971", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "Hideaway 115BFF", "", "41 047 37", "2002", "current", "1", "1", "1", "1", "0", "", "", "1", "2", "2", "33.7", "33.7", "", "", "79.6", "69.5", "", "50.8", "", "2", "", "", "101", "1", "1", "49", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.5", "80.9", "", "", "", "", "81.0"]} +{"pcdb_id": 8972, "brand_name": "Boulter", "model_name": "Classic", "model_qualifier": "135/165A", "winter_efficiency_pct": 85.7, "summer_efficiency_pct": 74.0, "comparative_hot_water_efficiency_pct": 54.1, "output_kw_max": 48.4, "final_year_of_manufacture": 2005, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008972", "000041", "0", "2012/Mar/27 10:12", "Boulter Boilers", "Boulter", "Classic", "135/165A", "", "2002", "2005", "4", "1", "1", "1", "0", "", "", "1", "3", "2", "39.5", "48.4", "", "", "85.7", "74.0", "", "54.1", "", "2", "", "", "201", "1", "1", "150", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.4", "86.1", "", "", "", "", "86.0"]} +{"pcdb_id": 8973, "brand_name": "Boulter", "model_name": "Bonus", "model_qualifier": "Combi 90A", "winter_efficiency_pct": 83.4, "summer_efficiency_pct": 75.3, "comparative_hot_water_efficiency_pct": 35.4, "output_kw_max": 26.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 1, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008973", "000041", "0", "2024/Jan/31 10:17", "Boulter Boilers", "Boulter", "Bonus", "Combi 90A", "", "2002", "obsolete", "4", "1", "2", "2", "0", "", "", "1", "3", "2", "26.4", "26.4", "", "", "83.4", "75.3", "", "35.4", "", "2", "", "", "203", "1", "1", "145", "0", "1", "1", "0", "40", "0", "15", "3", "82", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "84.8", "85.7", "", "", "", "", "85.6"]} +{"pcdb_id": 8976, "brand_name": "Worcester", "model_name": "26 CDi Xtra", "model_qualifier": "RSF", "winter_efficiency_pct": 85.9, "summer_efficiency_pct": 77.3, "comparative_hot_water_efficiency_pct": 54.3, "output_kw_max": 26.0, "final_year_of_manufacture": 2005, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008976", "000035", "0", "2020/Sep/04 08:01", "Worcester Heat Systems", "Worcester", "26 CDi Xtra", "RSF", "47 311 42", "1998", "2005", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "26", "26", "", "", "85.9", "77.3", "", "54.3", "", "2", "1", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "92.0", "", "", "", "", "91.2"]} +{"pcdb_id": 8977, "brand_name": "Worcester", "model_name": "15 SBi", "model_qualifier": "RSF", "winter_efficiency_pct": 81.8, "summer_efficiency_pct": 71.7, "comparative_hot_water_efficiency_pct": 52.4, "output_kw_max": 15.0, "final_year_of_manufacture": 2005, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008977", "000035", "0", "2020/Sep/04 08:01", "Worcester Heat Systems", "Worcester", "15 SBi", "RSF", "41 311 45", "1999", "2005", "2", "2", "1", "1", "0", "", "", "1", "2", "2", "6", "15", "", "", "81.8", "71.7", "", "52.4", "", "2", "1", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "83.0", "85.4", "", "", "", "", "84.9"]} +{"pcdb_id": 8978, "brand_name": "Worcester", "model_name": "24 SBi", "model_qualifier": "RSF", "winter_efficiency_pct": 81.0, "summer_efficiency_pct": 70.9, "comparative_hot_water_efficiency_pct": 51.8, "output_kw_max": 24.0, "final_year_of_manufacture": 2005, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008978", "000035", "0", "2020/Sep/04 08:02", "Worcester Heat Systems", "Worcester", "24 SBi", "RSF", "41 311 46", "1999", "2005", "2", "2", "1", "1", "0", "", "", "1", "2", "2", "15", "24", "", "", "81.0", "70.9", "", "51.8", "", "2", "1", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "84.4", "80.8", "", "", "", "", "81.5"]} +{"pcdb_id": 8979, "brand_name": "Trianco", "model_name": "Eurotrader", "model_qualifier": "50/90", "winter_efficiency_pct": 86.5, "summer_efficiency_pct": 74.8, "comparative_hot_water_efficiency_pct": 54.7, "output_kw_max": 26.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008979", "000062", "0", "2012/Mar/27 10:12", "Trianco Redfyre", "Trianco", "Eurotrader", "50/90", "13961/2", "1997", "current", "4", "1", "2", "1", "0", "", "", "1", "1", "1", "14.65", "26.3", "", "", "86.5", "74.8", "", "54.7", "", "2", "", "", "201", "1", "1", "148", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.9", "88.8", "", "", "", "", "88.3"]} +{"pcdb_id": 8980, "brand_name": "Trianco", "model_name": "Eurostar", "model_qualifier": "Combi 90", "winter_efficiency_pct": 84.6, "summer_efficiency_pct": 76.5, "comparative_hot_water_efficiency_pct": 45.6, "output_kw_max": 27.5, "final_year_of_manufacture": 2007, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008980", "000062", "0", "2024/Jan/31 10:17", "Trianco Redfyre", "Trianco", "Eurostar", "Combi 90", "12579/1", "1997", "2007", "4", "1", "2", "2", "0", "", "", "1", "1", "1", "20.5", "27.5", "", "", "84.6", "76.5", "", "45.6", "", "2", "", "", "203", "1", "1", "1.2", "5.5", "2", "1", "0", "63", "0", "25", "1", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.9", "88.8", "", "", "", "", "88.3"]} +{"pcdb_id": 8981, "brand_name": "Trianco", "model_name": "Eurostar", "model_qualifier": "External 65 wm", "winter_efficiency_pct": 86.6, "summer_efficiency_pct": 74.9, "comparative_hot_water_efficiency_pct": 54.7, "output_kw_max": 19.0, "final_year_of_manufacture": 2007, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008981", "000062", "0", "2012/Mar/27 10:12", "Trianco Redfyre", "Trianco", "Eurostar", "External 65 wm", "13961/10", "1998", "2007", "4", "2", "2", "1", "0", "", "", "1", "1", "1", "14.6", "19", "", "", "86.6", "74.9", "", "54.7", "", "2", "", "", "201", "1", "1", "148", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.1", "87.8", "", "", "", "", "87.5"]} +{"pcdb_id": 8982, "brand_name": "Trianco", "model_name": "Eurostar", "model_qualifier": "Utility 190/240", "winter_efficiency_pct": 86.3, "summer_efficiency_pct": 74.6, "comparative_hot_water_efficiency_pct": 54.5, "output_kw_max": 70.0, "final_year_of_manufacture": 2007, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008982", "000062", "0", "2012/Mar/27 10:12", "Trianco Redfyre", "Trianco", "Eurostar", "Utility 190/240", "13961/6", "1998", "2007", "4", "1", "2", "1", "0", "", "", "1", "1", "1", "55.7", "70", "", "", "86.3", "74.6", "", "54.5", "", "2", "", "", "201", "1", "1", "148", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.1", "86.6", "", "", "", "", "86.5"]} +{"pcdb_id": 8983, "brand_name": "Trianco", "model_name": "Eurostar", "model_qualifier": "Utility 160/180", "winter_efficiency_pct": 86.3, "summer_efficiency_pct": 74.6, "comparative_hot_water_efficiency_pct": 54.5, "output_kw_max": 52.7, "final_year_of_manufacture": 2007, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008983", "000062", "0", "2012/Mar/27 10:12", "Trianco Redfyre", "Trianco", "Eurostar", "Utility 160/180", "13161/5", "1998", "2007", "4", "1", "2", "1", "0", "", "", "1", "1", "1", "46.9", "52.7", "", "", "86.3", "74.6", "", "54.5", "", "2", "", "", "201", "1", "1", "148", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.8", "86.8", "", "", "", "", "86.6"]} +{"pcdb_id": 8985, "brand_name": "Trianco", "model_name": "Iona", "model_qualifier": "100/125", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 36.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008985", "000062", "0", "2012/Mar/27 10:12", "Trianco Redfyre", "Trianco", "Iona", "100/125", "13961/3", "1997", "current", "4", "1", "2", "1", "0", "", "", "1", "1", "1", "29.3", "36.6", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "148", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.4", "90.5", "", "", "", "", "89.7"]} +{"pcdb_id": 8986, "brand_name": "Trianco", "model_name": "Eurostar", "model_qualifier": "Utility 100/125", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 36.6, "final_year_of_manufacture": 2007, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008986", "000062", "0", "2012/Mar/27 10:12", "Trianco Redfyre", "Trianco", "Eurostar", "Utility 100/125", "13961/3", "1997", "2007", "4", "1", "2", "1", "0", "", "", "1", "1", "1", "29.3", "36.6", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "148", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.4", "90.5", "", "", "", "", "89.7"]} +{"pcdb_id": 8988, "brand_name": "Trianco", "model_name": "Eurotrader", "model_qualifier": "100/125", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 36.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008988", "000062", "0", "2012/Mar/27 10:12", "Trianco Redfyre", "Trianco", "Eurotrader", "100/125", "13961/3", "1997", "current", "4", "1", "2", "1", "0", "", "", "1", "1", "1", "29.3", "36.6", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "148", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.4", "90.5", "", "", "", "", "89.7"]} +{"pcdb_id": 8989, "brand_name": "Trianco", "model_name": "Eurostar", "model_qualifier": "External 50/90", "winter_efficiency_pct": 86.5, "summer_efficiency_pct": 74.8, "comparative_hot_water_efficiency_pct": 54.7, "output_kw_max": 26.3, "final_year_of_manufacture": 2007, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008989", "000062", "0", "2012/Mar/27 10:12", "Trianco Redfyre", "Trianco", "Eurostar", "External 50/90", "13961/2", "1997", "2007", "4", "1", "2", "1", "0", "", "", "1", "1", "1", "14.65", "26.3", "", "", "86.5", "74.8", "", "54.7", "", "2", "", "", "201", "1", "1", "148", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.9", "88.8", "", "", "", "", "88.3"]} +{"pcdb_id": 8990, "brand_name": "Trianco", "model_name": "Eurostar", "model_qualifier": "2000 70/90", "winter_efficiency_pct": 86.5, "summer_efficiency_pct": 74.8, "comparative_hot_water_efficiency_pct": 54.7, "output_kw_max": 26.3, "final_year_of_manufacture": 2007, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008990", "000062", "0", "2012/Mar/27 10:12", "Trianco Redfyre", "Trianco", "Eurostar", "2000 70/90", "13961/2", "1997", "2007", "4", "1", "2", "1", "0", "", "", "1", "1", "1", "20.5", "26.3", "", "", "86.5", "74.8", "", "54.7", "", "2", "", "", "201", "1", "1", "148", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.9", "88.8", "", "", "", "", "88.3"]} +{"pcdb_id": 8991, "brand_name": "Trianco", "model_name": "Iona", "model_qualifier": "50/90", "winter_efficiency_pct": 86.5, "summer_efficiency_pct": 74.8, "comparative_hot_water_efficiency_pct": 54.7, "output_kw_max": 26.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008991", "000062", "0", "2012/Mar/27 10:12", "Trianco Redfyre", "Trianco", "Iona", "50/90", "13961/2", "1997", "current", "4", "1", "2", "1", "0", "", "", "1", "1", "1", "14.65", "26.3", "", "", "86.5", "74.8", "", "54.7", "", "2", "", "", "201", "1", "1", "148", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.9", "88.8", "", "", "", "", "88.3"]} +{"pcdb_id": 8992, "brand_name": "Trianco", "model_name": "Eurostar", "model_qualifier": "Utility System 50/90", "winter_efficiency_pct": 86.5, "summer_efficiency_pct": 74.8, "comparative_hot_water_efficiency_pct": 54.7, "output_kw_max": 26.3, "final_year_of_manufacture": 2007, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008992", "000062", "0", "2012/Mar/27 10:12", "Trianco Redfyre", "Trianco", "Eurostar", "Utility System 50/90", "13961/2", "1997", "2007", "4", "1", "2", "1", "0", "", "", "1", "1", "1", "20.5", "26.3", "", "", "86.5", "74.8", "", "54.7", "", "2", "", "", "201", "1", "1", "148", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.9", "88.8", "", "", "", "", "88.3"]} +{"pcdb_id": 8993, "brand_name": "Trianco", "model_name": "Eurostar", "model_qualifier": "Utility 70/90", "winter_efficiency_pct": 86.5, "summer_efficiency_pct": 74.8, "comparative_hot_water_efficiency_pct": 54.7, "output_kw_max": 26.3, "final_year_of_manufacture": 2007, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008993", "000062", "0", "2012/Mar/27 10:12", "Trianco Redfyre", "Trianco", "Eurostar", "Utility 70/90", "13961/2", "1997", "2007", "4", "1", "2", "1", "0", "", "", "1", "1", "1", "20.5", "26.3", "", "", "86.5", "74.8", "", "54.7", "", "2", "", "", "201", "1", "1", "148", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.9", "88.8", "", "", "", "", "88.3"]} +{"pcdb_id": 8994, "brand_name": "Trianco", "model_name": "Eurostar", "model_qualifier": "Combi 65", "winter_efficiency_pct": 84.1, "summer_efficiency_pct": 76.0, "comparative_hot_water_efficiency_pct": 45.3, "output_kw_max": 19.0, "final_year_of_manufacture": 2007, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008994", "000062", "0", "2024/Jan/31 10:17", "Trianco Redfyre", "Trianco", "Eurostar", "Combi 65", "C16496/1", "2002", "2007", "4", "1", "1", "2", "0", "", "", "1", "2", "2", "14.7", "19.0", "", "", "84.1", "76.0", "", "45.3", "", "2", "", "", "203", "1", "1", "1.2", "5.5", "2", "1", "0", "63", "0", "25", "2", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.9", "86.1", "", "", "", "", "86.1"]} +{"pcdb_id": 8995, "brand_name": "Trianco", "model_name": "Eurostar", "model_qualifier": "Combi 50", "winter_efficiency_pct": 84.1, "summer_efficiency_pct": 76.0, "comparative_hot_water_efficiency_pct": 45.3, "output_kw_max": 19.0, "final_year_of_manufacture": 2002, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008995", "000062", "0", "2024/Jan/31 10:17", "Trianco Redfyre", "Trianco", "Eurostar", "Combi 50", "C16496/1", "2002", "2002", "4", "1", "1", "2", "0", "", "", "1", "2", "2", "14.7", "19", "", "", "84.1", "76.0", "", "45.3", "", "2", "", "", "203", "1", "1", "1.2", "5.5", "2", "1", "0", "63", "0", "25", "2", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.9", "86.1", "", "", "", "", "86.1"]} +{"pcdb_id": 8996, "brand_name": "Trianco", "model_name": "Eurostar", "model_qualifier": "2000 50/65", "winter_efficiency_pct": 86.0, "summer_efficiency_pct": 74.3, "comparative_hot_water_efficiency_pct": 54.3, "output_kw_max": 19.0, "final_year_of_manufacture": 2007, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008996", "000062", "0", "2012/Mar/27 10:12", "Trianco Redfyre", "Trianco", "Eurostar", "2000 50/65", "C16496/1", "2002", "2007", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "14.7", "19.0", "", "", "86.0", "74.3", "", "54.3", "", "2", "", "", "201", "1", "1", "70", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.9", "86.1", "", "", "", "", "86.1"]} +{"pcdb_id": 8997, "brand_name": "Trianco", "model_name": "Eurostar", "model_qualifier": "Utility 50/65 C16496/1", "winter_efficiency_pct": 86.0, "summer_efficiency_pct": 74.3, "comparative_hot_water_efficiency_pct": 54.3, "output_kw_max": 19.0, "final_year_of_manufacture": 2007, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008997", "000062", "0", "2012/Mar/27 10:12", "Trianco Redfyre", "Trianco", "Eurostar", "Utility 50/65 C16496/1", "", "2002", "2007", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "14.7", "19.0", "", "", "86.0", "74.3", "", "54.3", "", "2", "", "", "201", "1", "1", "70", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.9", "86.1", "", "", "", "", "86.1"]} +{"pcdb_id": 8998, "brand_name": "Trianco", "model_name": "Eurostar", "model_qualifier": "External 95/115", "winter_efficiency_pct": 85.6, "summer_efficiency_pct": 73.9, "comparative_hot_water_efficiency_pct": 54.0, "output_kw_max": 33.7, "final_year_of_manufacture": 2007, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008998", "000062", "0", "2012/Mar/27 10:12", "Trianco Redfyre", "Trianco", "Eurostar", "External 95/115", "C16880/1", "2000", "2007", "4", "1", "2", "1", "0", "", "", "1", "1", "2", "27.8", "33.7", "", "", "85.6", "73.9", "", "54.0", "", "2", "", "", "201", "1", "1", "90", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "84.8", "86.4", "", "", "", "", "86.1"]} +{"pcdb_id": 8999, "brand_name": "Trianco", "model_name": "Eurostar", "model_qualifier": "Utility 130/150", "winter_efficiency_pct": 85.6, "summer_efficiency_pct": 73.9, "comparative_hot_water_efficiency_pct": 54.0, "output_kw_max": 44.0, "final_year_of_manufacture": 2007, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["008999", "000062", "0", "2012/Mar/27 10:12", "Trianco Redfyre", "Trianco", "Eurostar", "Utility 130/150", "C16881/1", "2001", "2007", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "38.1", "44.0", "", "", "85.6", "73.9", "", "54.0", "", "2", "", "", "201", "1", "1", "90", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "84.7", "86.6", "", "", "", "", "86.2"]} +{"pcdb_id": 9000, "brand_name": "Trianco", "model_name": "Eurostar", "model_qualifier": "Internal 50/70 wm", "winter_efficiency_pct": 85.6, "summer_efficiency_pct": 73.9, "comparative_hot_water_efficiency_pct": 54.0, "output_kw_max": 20.5, "final_year_of_manufacture": 2007, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009000", "000062", "0", "2012/Mar/27 10:12", "Trianco Redfyre", "Trianco", "Eurostar", "Internal 50/70 wm", "C16495/1", "2001", "2007", "4", "2", "1", "1", "0", "", "", "1", "1", "2", "14.65", "20.5", "", "", "85.6", "73.9", "", "54.0", "", "2", "", "", "201", "1", "1", "70", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.4", "85.9", "", "", "", "", "85.8"]} +{"pcdb_id": 9001, "brand_name": "Trianco", "model_name": "Iona", "model_qualifier": "50/70 wm", "winter_efficiency_pct": 85.6, "summer_efficiency_pct": 73.9, "comparative_hot_water_efficiency_pct": 54.0, "output_kw_max": 20.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009001", "000062", "0", "2012/Mar/27 10:12", "Trianco Redfyre", "Trianco", "Iona", "50/70 wm", "C16495/1", "2001", "current", "4", "2", "1", "1", "0", "", "", "1", "1", "2", "14.65", "20.5", "", "", "85.6", "73.9", "", "54.0", "", "2", "", "", "201", "1", "1", "70", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.4", "85.9", "", "", "", "", "85.8"]} +{"pcdb_id": 9002, "brand_name": "Firebird", "model_name": "Popular", "model_qualifier": "150-200", "winter_efficiency_pct": 86.4, "summer_efficiency_pct": 74.7, "comparative_hot_water_efficiency_pct": 54.6, "output_kw_max": 58.61, "final_year_of_manufacture": 2013, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009002", "000047", "0", "2018/Jan/03 12:36", "Firebird Boilers", "Firebird", "Popular", "150-200", "", "", "2013", "4", "1", "1", "1", "0", "", "", "1", "2", "1", "43.96", "58.61", "", "", "86.4", "74.7", "", "54.6", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.1", "86.7", "", "", "", "", "86.6"]} +{"pcdb_id": 9004, "brand_name": "Firebird", "model_name": "Boilerhouse S", "model_qualifier": "150-200", "winter_efficiency_pct": 86.4, "summer_efficiency_pct": 74.7, "comparative_hot_water_efficiency_pct": 54.6, "output_kw_max": 58.61, "final_year_of_manufacture": 2013, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009004", "000047", "0", "2018/Jan/03 12:34", "Firebird Boilers", "Firebird", "Boilerhouse S", "150-200", "", "", "2013", "4", "1", "1", "1", "0", "", "", "1", "2", "1", "43.96", "58.61", "", "", "86.4", "74.7", "", "54.6", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.1", "86.7", "", "", "", "", "86.6"]} +{"pcdb_id": 9005, "brand_name": "Firebird", "model_name": "S (White Cased)", "model_qualifier": "150-200", "winter_efficiency_pct": 86.4, "summer_efficiency_pct": 74.7, "comparative_hot_water_efficiency_pct": 54.6, "output_kw_max": 58.61, "final_year_of_manufacture": 2013, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009005", "000047", "0", "2018/Jan/03 12:33", "Firebird Boilers", "Firebird", "S (White Cased)", "150-200", "", "", "2013", "4", "1", "1", "1", "0", "", "", "1", "2", "1", "43.96", "58.61", "", "", "86.4", "74.7", "", "54.6", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.1", "86.7", "", "", "", "", "86.6"]} +{"pcdb_id": 9006, "brand_name": "Firebird", "model_name": "Heatpac", "model_qualifier": "150-200", "winter_efficiency_pct": 86.4, "summer_efficiency_pct": 74.7, "comparative_hot_water_efficiency_pct": 54.6, "output_kw_max": 58.61, "final_year_of_manufacture": 2013, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009006", "000047", "0", "2018/Jan/03 12:31", "Firebird Boilers", "Firebird", "Heatpac", "150-200", "", "", "2013", "4", "1", "2", "1", "0", "", "", "1", "1", "1", "43.96", "58.61", "", "", "86.4", "74.7", "", "54.6", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.1", "86.7", "", "", "", "", "86.6"]} +{"pcdb_id": 9007, "brand_name": "Firebird", "model_name": "Popular", "model_qualifier": "200-250", "winter_efficiency_pct": 86.2, "summer_efficiency_pct": 74.5, "comparative_hot_water_efficiency_pct": 54.4, "output_kw_max": null, "final_year_of_manufacture": 2013, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009007", "000047", "0", "2018/Jan/03 13:12", "Firebird Boilers", "Firebird", "Popular", "200-250", "", "", "2013", "4", "1", "1", "1", "0", "", "", "1", "2", "1", "58.61", ">70kW", "", "", "86.2", "74.5", "", "54.4", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.5", "86.9", "", "", "", "", "86.6"]} +{"pcdb_id": 9008, "brand_name": "Firebird", "model_name": "Heatpac", "model_qualifier": "200-250", "winter_efficiency_pct": 86.2, "summer_efficiency_pct": 74.5, "comparative_hot_water_efficiency_pct": 54.4, "output_kw_max": null, "final_year_of_manufacture": 2013, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009008", "000047", "0", "2018/Jan/03 13:13", "Firebird Boilers", "Firebird", "Heatpac", "200-250", "", "", "2013", "4", "1", "2", "1", "0", "", "", "1", "1", "1", "58.61", ">70kW", "", "", "86.2", "74.5", "", "54.4", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.5", "86.9", "", "", "", "", "86.6"]} +{"pcdb_id": 9009, "brand_name": "Firebird", "model_name": "Boilerhouse S", "model_qualifier": "200-250", "winter_efficiency_pct": 86.2, "summer_efficiency_pct": 74.5, "comparative_hot_water_efficiency_pct": 54.4, "output_kw_max": null, "final_year_of_manufacture": 2013, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009009", "000047", "0", "2018/Jan/03 13:14", "Firebird Boilers", "Firebird", "Boilerhouse S", "200-250", "", "", "2013", "4", "1", "1", "1", "0", "", "", "1", "2", "1", "58.61", ">70kW", "", "", "86.2", "74.5", "", "54.4", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.5", "86.9", "", "", "", "", "86.6"]} +{"pcdb_id": 9010, "brand_name": "Firebird", "model_name": "S (White Cased)", "model_qualifier": "200-250", "winter_efficiency_pct": 86.2, "summer_efficiency_pct": 74.5, "comparative_hot_water_efficiency_pct": 54.4, "output_kw_max": null, "final_year_of_manufacture": 2013, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009010", "000047", "0", "2018/Jan/03 13:14", "Firebird Boilers", "Firebird", "S (White Cased)", "200-250", "", "", "2013", "4", "1", "1", "1", "0", "", "", "1", "2", "1", "58.61", ">70kW", "", "", "86.2", "74.5", "", "54.4", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.5", "86.9", "", "", "", "", "86.6"]} +{"pcdb_id": 9015, "brand_name": "Vaillant", "model_name": "Ecomax", "model_qualifier": "613/2E", "winter_efficiency_pct": 89.3, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 13.5, "final_year_of_manufacture": 2010, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009015", "000031", "0", "2012/Mar/27 10:12", "Vaillant", "Vaillant", "Ecomax", "613/2E", "VU GBV126/2 E-C", "2001", "2010", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "13.5", "13.5", "", "", "89.3", "80.3", "", "58.6", "", "2", "1", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "92.0", "98.7", "", "", "", "", "97.5"]} +{"pcdb_id": 9016, "brand_name": "Vaillant", "model_name": "Ecomax", "model_qualifier": "618/2E", "winter_efficiency_pct": 89.3, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 18.4, "final_year_of_manufacture": 2010, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009016", "000031", "0", "2012/Mar/27 10:12", "Vaillant", "Vaillant", "Ecomax", "618/2E", "VU GB 196/2E-C", "2001", "2010", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "18.4", "18.4", "", "", "89.3", "80.3", "", "58.6", "", "2", "1", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "92.0", "98.8", "", "", "", "", "97.5"]} +{"pcdb_id": 9017, "brand_name": "Vaillant", "model_name": "Ecomax", "model_qualifier": "622/2E", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 22.4, "final_year_of_manufacture": 2010, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009017", "000031", "0", "2012/Mar/27 10:12", "Vaillant", "Vaillant", "Ecomax", "622/2E", "VU GB 246/2E-C", "2001", "2010", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "22.4", "22.4", "", "", "89.2", "80.2", "", "58.6", "", "2", "1", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "92.0", "98.6", "", "", "", "", "97.4"]} +{"pcdb_id": 9018, "brand_name": "Vaillant", "model_name": "Ecomax", "model_qualifier": "824/2E", "winter_efficiency_pct": 89.3, "summer_efficiency_pct": 80.7, "comparative_hot_water_efficiency_pct": 56.7, "output_kw_max": 18.4, "final_year_of_manufacture": 2010, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009018", "000031", "0", "2010/Jan/28 08:17", "Vaillant", "Vaillant", "Ecomax", "824/2E", "VUW 246/2E-C", "2001", "2010", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "18.4", "18.4", "", "", "89.3", "80.7", "", "56.7", "", "2", "1", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "92.0", "98.8", "", "", "", "", "97.5"]} +{"pcdb_id": 9019, "brand_name": "Vaillant", "model_name": "Ecomax", "model_qualifier": "828/2E", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 80.6, "comparative_hot_water_efficiency_pct": 56.7, "output_kw_max": 22.4, "final_year_of_manufacture": 2010, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009019", "000031", "0", "2010/Jan/28 08:31", "Vaillant", "Vaillant", "Ecomax", "828/2E", "VUW 286/2E-C", "2001", "2010", "2", "2", "2", "2", "0", "", "", "2", "2", "2", "22.4", "22.4", "", "", "89.2", "80.6", "", "56.7", "", "2", "1", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "92.0", "98.6", "", "", "", "", "97.4"]} +{"pcdb_id": 9020, "brand_name": "Vaillant", "model_name": "Ecomax", "model_qualifier": "835/2 E", "winter_efficiency_pct": 89.5, "summer_efficiency_pct": 80.9, "comparative_hot_water_efficiency_pct": 56.9, "output_kw_max": 27.0, "final_year_of_manufacture": 2010, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009020", "000031", "0", "2010/Jan/28 08:49", "Vaillant", "Vaillant", "Ecomax", "835/2 E", "VUW 356 - C", "2001", "2010", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "27.0", "27.0", "", "", "89.5", "80.9", "", "56.9", "", "2", "1", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "92.0", "99.3", "", "", "", "", "97.9"]} +{"pcdb_id": 9021, "brand_name": "Vaillant", "model_name": "Thermocompact", "model_qualifier": "615E", "winter_efficiency_pct": 81.8, "summer_efficiency_pct": 71.1, "comparative_hot_water_efficiency_pct": 51.9, "output_kw_max": 15.0, "final_year_of_manufacture": 2010, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009021", "000031", "0", "2012/Mar/27 10:12", "Vaillant", "Vaillant", "Thermocompact", "615E", "VU GB 152-5E", "2000", "2010", "2", "2", "1", "1", "0", "", "", "1", "2", "2", "15", "15", "", "", "81.8", "71.1", "", "51.9", "", "2", "1", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "83.5", "82.1", "", "", "", "", "82.3"]} +{"pcdb_id": 9022, "brand_name": "Vaillant", "model_name": "Thermocompact", "model_qualifier": "620E", "winter_efficiency_pct": 82.5, "summer_efficiency_pct": 71.8, "comparative_hot_water_efficiency_pct": 52.5, "output_kw_max": 20.0, "final_year_of_manufacture": 2010, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009022", "000031", "0", "2012/Mar/27 10:12", "Vaillant", "Vaillant", "Thermocompact", "620E", "VU GB 202-5E", "2000", "2010", "2", "2", "1", "1", "0", "", "", "1", "2", "2", "20.0", "20.0", "", "", "82.5", "71.8", "", "52.5", "", "2", "1", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "83.4", "83.6", "", "", "", "", "83.6"]} +{"pcdb_id": 9023, "brand_name": "Vaillant", "model_name": "Thermocompact", "model_qualifier": "624 E", "winter_efficiency_pct": 82.5, "summer_efficiency_pct": 71.8, "comparative_hot_water_efficiency_pct": 52.4, "output_kw_max": 24.0, "final_year_of_manufacture": 2010, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009023", "000031", "0", "2012/Mar/27 10:12", "Vaillant", "Vaillant", "Thermocompact", "624 E", "VU GB 242-5E", "2000", "2010", "2", "2", "1", "1", "0", "", "", "1", "2", "2", "24", "24", "", "", "82.5", "71.8", "", "52.4", "", "2", "1", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "83.2", "84.0", "", "", "", "", "83.8"]} +{"pcdb_id": 9024, "brand_name": "Vaillant", "model_name": "Thermocompact", "model_qualifier": "628E", "winter_efficiency_pct": 82.6, "summer_efficiency_pct": 71.9, "comparative_hot_water_efficiency_pct": 52.5, "output_kw_max": 28.0, "final_year_of_manufacture": 2010, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009024", "000031", "0", "2012/Mar/27 10:12", "Vaillant", "Vaillant", "Thermocompact", "628E", "VU GB 282-5E", "2000", "2010", "2", "2", "1", "1", "0", "", "", "1", "2", "2", "28", "28", "", "", "82.6", "71.9", "", "52.5", "", "2", "1", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "83.4", "83.8", "", "", "", "", "83.7"]} +{"pcdb_id": 9025, "brand_name": "Vaillant", "model_name": "Turbomax Plus", "model_qualifier": "824E", "winter_efficiency_pct": 82.3, "summer_efficiency_pct": 72.2, "comparative_hot_water_efficiency_pct": 50.8, "output_kw_max": 24.0, "final_year_of_manufacture": 2010, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009025", "000031", "0", "2010/Jan/28 08:50", "Vaillant", "Vaillant", "Turbomax Plus", "824E", "VUW GB 242-5E", "2000", "2010", "2", "2", "1", "2", "0", "", "", "1", "2", "2", "24", "24", "", "", "82.3", "72.2", "", "50.8", "", "2", "1", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "83.2", "84.0", "", "", "", "", "83.8"]} +{"pcdb_id": 9026, "brand_name": "Vaillant", "model_name": "Turbomax Plus", "model_qualifier": "828E", "winter_efficiency_pct": 82.4, "summer_efficiency_pct": 72.3, "comparative_hot_water_efficiency_pct": 50.8, "output_kw_max": 28.0, "final_year_of_manufacture": 2010, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009026", "000031", "0", "2010/Jan/28 08:49", "Vaillant", "Vaillant", "Turbomax Plus", "828E", "VUW GB 282-5E", "2000", "2010", "2", "2", "1", "2", "0", "", "", "1", "2", "2", "28", "28", "", "", "82.4", "72.3", "", "50.8", "", "2", "1", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "83.4", "83.8", "", "", "", "", "83.7"]} +{"pcdb_id": 9027, "brand_name": "Vaillant", "model_name": "Turbomax Plus", "model_qualifier": "28E", "winter_efficiency_pct": 82.4, "summer_efficiency_pct": 72.3, "comparative_hot_water_efficiency_pct": 50.8, "output_kw_max": 28.0, "final_year_of_manufacture": 2010, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009027", "000031", "0", "2010/Jan/28 08:50", "Vaillant", "Vaillant", "Turbomax Plus", "28E", "VUW GB 282-3E", "2000", "2010", "2", "2", "1", "2", "0", "", "", "1", "2", "2", "28", "28", "", "", "82.4", "72.3", "", "50.8", "", "2", "1", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "83.4", "83.8", "", "", "", "", "83.7"]} +{"pcdb_id": 9028, "brand_name": "Firebird", "model_name": "Popular", "model_qualifier": "90-120", "winter_efficiency_pct": 86.4, "summer_efficiency_pct": 74.7, "comparative_hot_water_efficiency_pct": 54.6, "output_kw_max": 35.17, "final_year_of_manufacture": 2013, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009028", "000047", "0", "2018/Jan/03 12:42", "Firebird Boilers", "Firebird", "Popular", "90-120", "", "", "2013", "4", "1", "1", "1", "0", "", "", "1", "2", "1", "26.38", "35.17", "", "", "86.4", "74.7", "", "54.6", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.4", "86.7", "", "", "", "", "86.6"]} +{"pcdb_id": 9029, "brand_name": "Firebird", "model_name": "Heatpac", "model_qualifier": "90-120", "winter_efficiency_pct": 86.4, "summer_efficiency_pct": 74.7, "comparative_hot_water_efficiency_pct": 54.6, "output_kw_max": 35.17, "final_year_of_manufacture": 2013, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009029", "000047", "0", "2018/Jan/03 12:42", "Firebird Boilers", "Firebird", "Heatpac", "90-120", "", "", "2013", "4", "1", "2", "1", "0", "", "", "1", "1", "1", "26.38", "35.17", "", "", "86.4", "74.7", "", "54.6", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.4", "86.7", "", "", "", "", "86.6"]} +{"pcdb_id": 9030, "brand_name": "Firebird", "model_name": "S (White cased)", "model_qualifier": "90-120", "winter_efficiency_pct": 86.4, "summer_efficiency_pct": 74.7, "comparative_hot_water_efficiency_pct": 54.6, "output_kw_max": 35.17, "final_year_of_manufacture": 2013, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009030", "000047", "0", "2018/Jan/03 12:43", "Firebird Boilers", "Firebird", "S (White cased)", "90-120", "", "", "2013", "4", "1", "1", "1", "0", "", "", "1", "2", "1", "26.38", "35.17", "", "", "86.4", "74.7", "", "54.6", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.4", "86.7", "", "", "", "", "86.6"]} +{"pcdb_id": 9031, "brand_name": "Firebird", "model_name": "Roomsealed Popular (Hideaway)", "model_qualifier": "90-120", "winter_efficiency_pct": 86.4, "summer_efficiency_pct": 74.7, "comparative_hot_water_efficiency_pct": 54.6, "output_kw_max": 35.17, "final_year_of_manufacture": 2010, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009031", "000047", "0", "2012/Mar/27 10:12", "Firebird Boilers", "Firebird", "Roomsealed Popular (Hideaway)", "90-120", "", "", "2010", "4", "1", "1", "1", "0", "", "", "1", "2", "1", "26.38", "35.17", "", "", "86.4", "74.7", "", "54.6", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.4", "86.7", "", "", "", "", "86.6"]} +{"pcdb_id": 9032, "brand_name": "Firebird", "model_name": "Boilerhouse S", "model_qualifier": "90-120", "winter_efficiency_pct": 86.4, "summer_efficiency_pct": 74.7, "comparative_hot_water_efficiency_pct": 54.6, "output_kw_max": 35.17, "final_year_of_manufacture": 2013, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009032", "000047", "0", "2018/Jan/03 12:40", "Firebird Boilers", "Firebird", "Boilerhouse S", "90-120", "", "", "2013", "4", "1", "1", "1", "0", "", "", "1", "2", "1", "26.38", "35.17", "", "", "86.4", "74.7", "", "54.6", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.4", "86.7", "", "", "", "", "86.6"]} +{"pcdb_id": 9033, "brand_name": "Firebird", "model_name": "Heatpac S", "model_qualifier": "90-120", "winter_efficiency_pct": 86.4, "summer_efficiency_pct": 74.7, "comparative_hot_water_efficiency_pct": 54.6, "output_kw_max": 35.17, "final_year_of_manufacture": 2013, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009033", "000047", "0", "2018/Jan/03 12:39", "Firebird Boilers", "Firebird", "Heatpac S", "90-120", "", "", "2013", "4", "1", "2", "1", "0", "", "", "1", "1", "1", "26.38", "35.17", "", "", "86.4", "74.7", "", "54.6", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.4", "86.7", "", "", "", "", "86.6"]} +{"pcdb_id": 9034, "brand_name": "Worcester", "model_name": "28 CDi - L", "model_qualifier": "RSF", "winter_efficiency_pct": 81.6, "summer_efficiency_pct": 71.5, "comparative_hot_water_efficiency_pct": 50.2, "output_kw_max": 24.0, "final_year_of_manufacture": 2005, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009034", "000035", "0", "2020/Sep/04 08:02", "Worcester Heat Systems", "Worcester", "28 CDi - L", "RSF", "47 311 35", "1997", "2005", "2", "2", "1", "2", "0", "", "", "1", "2", "2", "24", "24", "", "", "81.6", "71.5", "", "50.2", "", "2", "1", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "84.0", "81.5", "", "", "", "", "82.0"]} +{"pcdb_id": 9036, "brand_name": "DD Heating", "model_name": "Heatline", "model_qualifier": "Star 24", "winter_efficiency_pct": 79.5, "summer_efficiency_pct": 69.4, "comparative_hot_water_efficiency_pct": 48.8, "output_kw_max": 23.17, "final_year_of_manufacture": 2004, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009036", "000215", "0", "2011/Aug/31 10:31", "Turk Demir Dokum Fab AS", "DD Heating", "Heatline", "Star 24", "GC No. 47-157-01", "2001", "2004", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "23.17", "23.17", "", "", "79.5", "69.4", "", "48.8", "", "2", "", "", "104", "1", "2", "170", "17", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.5", "79.8", "", "", "", "", "80.2"]} +{"pcdb_id": 9037, "brand_name": "HRM Boilers", "model_name": "Wallstar 25/19", "model_qualifier": "20", "winter_efficiency_pct": 84.2, "summer_efficiency_pct": 76.1, "comparative_hot_water_efficiency_pct": 42.3, "output_kw_max": 25.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 1, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009037", "000098", "0", "2024/Jan/31 10:17", "HRM Boilers", "HRM Boilers", "Wallstar 25/19", "20", "20020308", "2002", "current", "4", "2", "1", "2", "0", "", "", "1", "2", "2", "19", "25.4", "", "", "84.2", "76.1", "", "42.3", "", "2", "", "", "203", "1", "1", "140", "0", "1", "2", "0", "32.5", "0", "25", "1", "82", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.5", "86.4", "", "", "", "", "86.2"]} +{"pcdb_id": 9038, "brand_name": "Sime", "model_name": "Planet Super 4 F.S.", "model_qualifier": "", "winter_efficiency_pct": 81.3, "summer_efficiency_pct": 72.2, "comparative_hot_water_efficiency_pct": 37.6, "output_kw_max": 29.0, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009038", "000213", "0", "2024/Jan/31 10:17", "Fonderie Sime S.p.A.", "Sime", "Planet Super 4 F.S.", "", "", "2002", "2018", "1", "1", "1", "2", "0", "", "", "1", "2", "2", "29.0", "29.0", "", "", "81.3", "72.2", "", "37.6", "", "2", "", "", "106", "1", "2", "180", "", "2", "1", "0", "62.8", "0", "16", "2", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.7", "81.6", "", "", "", "", "81.8"]} +{"pcdb_id": 9039, "brand_name": "Chaffoteaux et Maury", "model_name": "Centora Green 18-24", "model_qualifier": "Eurocondens 18-24", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 56.4, "output_kw_max": 24.0, "final_year_of_manufacture": 2002, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009039", "000010", "0", "2006/Jan/17 12:55", "Chaffoteaux et Maury", "Chaffoteaux et Maury", "Centora Green 18-24", "Eurocondens 18-24", "", "2002", "2002", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.0", "24.0", "", "", "88.8", "80.2", "", "56.4", "", "2", "", "", "104", "1", "2", "150", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.8", "98.6", "", "", "", "", "96.7"]} +{"pcdb_id": 9041, "brand_name": "Chaffoteaux et Maury", "model_name": "Britony System 100", "model_qualifier": "", "winter_efficiency_pct": 79.5, "summer_efficiency_pct": 68.8, "comparative_hot_water_efficiency_pct": 50.3, "output_kw_max": 28.0, "final_year_of_manufacture": 2003, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009041", "000010", "0", "2012/Mar/27 10:12", "Chaffoteaux et Maury", "Chaffoteaux et Maury", "Britony System 100", "", "", "1998", "2003", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "28", "28", "", "", "79.5", "68.8", "", "50.3", "", "2", "", "", "102", "1", "2", "150", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.5", "78.5", "", "", "", "", "79.2"]} +{"pcdb_id": 9042, "brand_name": "Chaffoteaux et Maury", "model_name": "Britony System 60", "model_qualifier": "", "winter_efficiency_pct": 79.9, "summer_efficiency_pct": 69.2, "comparative_hot_water_efficiency_pct": 50.6, "output_kw_max": 18.0, "final_year_of_manufacture": 2002, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009042", "000010", "0", "2012/Mar/27 10:12", "Chaffoteaux et Maury", "Chaffoteaux et Maury", "Britony System 60", "", "", "2001", "2002", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "18", "18", "", "", "79.9", "69.2", "", "50.6", "", "2", "", "", "102", "1", "2", "150", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.6", "79.2", "", "", "", "", "79.8"]} +{"pcdb_id": 9043, "brand_name": "Chaffoteaux et Maury", "model_name": "Calydra 80 V2", "model_qualifier": "", "winter_efficiency_pct": 79.6, "summer_efficiency_pct": 69.5, "comparative_hot_water_efficiency_pct": 48.9, "output_kw_max": 24.0, "final_year_of_manufacture": 2003, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009043", "000010", "0", "2006/Jan/17 12:55", "Chaffoteaux et Maury", "Chaffoteaux et Maury", "Calydra 80 V2", "", "GC No 47.980.20", "2002", "2003", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "24.0", "24.0", "", "", "79.6", "69.5", "", "48.9", "", "2", "", "", "104", "1", "2", "150", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.6", "78.9", "", "", "", "", "79.6"]} +{"pcdb_id": 9044, "brand_name": "GAH Heating Products", "model_name": "Thermecon 40/60", "model_qualifier": "Select C/F", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 18.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009044", "000051", "0", "2012/Mar/27 10:12", "GAH Heating Products", "GAH Heating Products", "Thermecon 40/60", "Select C/F", "BFS40/60", "2002", "current", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "11.7", "18.2", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "88.2", "88.3", "", "", "", "", "88.2"]} +{"pcdb_id": 9045, "brand_name": "GAH Heating Products", "model_name": "Thermecon 40/60", "model_qualifier": "Option B/F", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 18.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009045", "000051", "0", "2012/Mar/27 10:12", "GAH Heating Products", "GAH Heating Products", "Thermecon 40/60", "Option B/F", "BFO40/60", "2002", "current", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "11.7", "18.2", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "88.2", "88.3", "", "", "", "", "88.2"]} +{"pcdb_id": 9046, "brand_name": "GAH Heating Products", "model_name": "Thermecon 40/60", "model_qualifier": "Option C/F", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 18.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009046", "000051", "0", "2012/Mar/27 10:12", "GAH Heating Products", "GAH Heating Products", "Thermecon 40/60", "Option C/F", "BFO40/60", "2002", "current", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "11.7", "18.2", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "88.2", "88.3", "", "", "", "", "88.2"]} +{"pcdb_id": 9047, "brand_name": "GAH Heating Products", "model_name": "Thermecon 40/60", "model_qualifier": "Select B/F", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 18.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009047", "000051", "0", "2012/Mar/27 10:12", "GAH Heating Products", "GAH Heating Products", "Thermecon 40/60", "Select B/F", "BFS40/60", "2002", "current", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "11.7", "18.2", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "88.2", "88.3", "", "", "", "", "88.2"]} +{"pcdb_id": 9048, "brand_name": "GAH Heating Products", "model_name": "Thermecon 60/80", "model_qualifier": "System B/F", "winter_efficiency_pct": 85.5, "summer_efficiency_pct": 73.8, "comparative_hot_water_efficiency_pct": 53.9, "output_kw_max": 23.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009048", "000051", "0", "2012/Mar/27 10:12", "GAH Heating Products", "GAH Heating Products", "Thermecon 60/80", "System B/F", "BFSYS60/80", "2002", "current", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "18.2", "23.4", "", "", "85.5", "73.8", "", "53.9", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.0", "84.9", "", "", "", "", "85.1"]} +{"pcdb_id": 9049, "brand_name": "GAH Heating Products", "model_name": "Thermecon 60/80", "model_qualifier": "System C/F", "winter_efficiency_pct": 85.5, "summer_efficiency_pct": 73.8, "comparative_hot_water_efficiency_pct": 53.9, "output_kw_max": 23.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009049", "000051", "0", "2012/Mar/27 10:12", "GAH Heating Products", "GAH Heating Products", "Thermecon 60/80", "System C/F", "CFSYS60/80", "2002", "current", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "18.2", "23.4", "", "", "85.5", "73.8", "", "53.9", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.0", "84.9", "", "", "", "", "85.1"]} +{"pcdb_id": 9050, "brand_name": "GAH Heating Products", "model_name": "Thermecon 60/80", "model_qualifier": "Select B/F", "winter_efficiency_pct": 85.5, "summer_efficiency_pct": 73.8, "comparative_hot_water_efficiency_pct": 53.9, "output_kw_max": 23.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009050", "000051", "0", "2012/Mar/27 10:12", "GAH Heating Products", "GAH Heating Products", "Thermecon 60/80", "Select B/F", "BFS60/80", "2002", "current", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "18.2", "23.4", "", "", "85.5", "73.8", "", "53.9", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.0", "84.9", "", "", "", "", "85.1"]} +{"pcdb_id": 9051, "brand_name": "GAH Heating Products", "model_name": "Thermecon 60/80", "model_qualifier": "Select C/F", "winter_efficiency_pct": 85.5, "summer_efficiency_pct": 73.8, "comparative_hot_water_efficiency_pct": 53.9, "output_kw_max": 23.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009051", "000051", "0", "2012/Mar/27 10:12", "GAH Heating Products", "GAH Heating Products", "Thermecon 60/80", "Select C/F", "CFS60/80", "2002", "current", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "18.2", "23.4", "", "", "85.5", "73.8", "", "53.9", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.0", "84.9", "", "", "", "", "85.1"]} +{"pcdb_id": 9052, "brand_name": "GAH Heating Products", "model_name": "Thermecon 60/80", "model_qualifier": "Option B/F", "winter_efficiency_pct": 85.5, "summer_efficiency_pct": 73.8, "comparative_hot_water_efficiency_pct": 53.9, "output_kw_max": 23.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009052", "000051", "0", "2012/Mar/27 10:12", "GAH Heating Products", "GAH Heating Products", "Thermecon 60/80", "Option B/F", "BFO60/80", "2002", "current", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "18.2", "23.4", "", "", "85.5", "73.8", "", "53.9", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.0", "84.9", "", "", "", "", "85.1"]} +{"pcdb_id": 9053, "brand_name": "GAH Heating Products", "model_name": "Thermecon 60/80", "model_qualifier": "Option C/F", "winter_efficiency_pct": 85.5, "summer_efficiency_pct": 73.8, "comparative_hot_water_efficiency_pct": 53.9, "output_kw_max": 23.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009053", "000051", "0", "2012/Mar/27 10:12", "GAH Heating Products", "GAH Heating Products", "Thermecon 60/80", "Option C/F", "CFO60/80", "2002", "current", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "18.2", "23.4", "", "", "85.5", "73.8", "", "53.9", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.0", "84.9", "", "", "", "", "85.1"]} +{"pcdb_id": 9054, "brand_name": "GAH Heating Products", "model_name": "Thermecon 80/95", "model_qualifier": "System B/F", "winter_efficiency_pct": 85.3, "summer_efficiency_pct": 73.6, "comparative_hot_water_efficiency_pct": 53.7, "output_kw_max": 27.8, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009054", "000051", "0", "2012/Mar/27 10:12", "GAH Heating Products", "GAH Heating Products", "Thermecon 80/95", "System B/F", "BFSYS80/95", "2002", "current", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "23.4", "27.8", "", "", "85.3", "73.6", "", "53.7", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.6", "84.9", "", "", "", "", "85.0"]} +{"pcdb_id": 9055, "brand_name": "GAH Heating Products", "model_name": "Thermecon 80/95", "model_qualifier": "System C/F", "winter_efficiency_pct": 85.3, "summer_efficiency_pct": 73.6, "comparative_hot_water_efficiency_pct": 53.7, "output_kw_max": 27.8, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009055", "000051", "0", "2012/Mar/27 10:12", "GAH Heating Products", "GAH Heating Products", "Thermecon 80/95", "System C/F", "CFSYS80/95", "2002", "current", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "23.4", "27.8", "", "", "85.3", "73.6", "", "53.7", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.6", "84.9", "", "", "", "", "85.0"]} +{"pcdb_id": 9056, "brand_name": "GAH Heating Products", "model_name": "Thermecon 80/95", "model_qualifier": "Select B/F", "winter_efficiency_pct": 85.3, "summer_efficiency_pct": 73.6, "comparative_hot_water_efficiency_pct": 53.7, "output_kw_max": 27.8, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009056", "000051", "0", "2012/Mar/27 10:12", "GAH Heating Products", "GAH Heating Products", "Thermecon 80/95", "Select B/F", "BFS80/95", "2002", "current", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "23.4", "27.8", "", "", "85.3", "73.6", "", "53.7", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.6", "84.9", "", "", "", "", "85.0"]} +{"pcdb_id": 9057, "brand_name": "GAH Heating Products", "model_name": "Thermecon 80/95", "model_qualifier": "Select C/F", "winter_efficiency_pct": 85.3, "summer_efficiency_pct": 73.6, "comparative_hot_water_efficiency_pct": 53.7, "output_kw_max": 27.8, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009057", "000051", "0", "2012/Mar/27 10:12", "GAH Heating Products", "GAH Heating Products", "Thermecon 80/95", "Select C/F", "CFS80/95", "2002", "current", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "23.4", "27.8", "", "", "85.3", "73.6", "", "53.7", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.6", "84.9", "", "", "", "", "85.0"]} +{"pcdb_id": 9058, "brand_name": "GAH Heating Products", "model_name": "Thermecon 80/95", "model_qualifier": "Option B/F", "winter_efficiency_pct": 85.3, "summer_efficiency_pct": 73.6, "comparative_hot_water_efficiency_pct": 53.7, "output_kw_max": 27.8, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009058", "000051", "0", "2012/Mar/27 10:12", "GAH Heating Products", "GAH Heating Products", "Thermecon 80/95", "Option B/F", "BFO80/95", "2002", "current", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "23.4", "27.8", "", "", "85.3", "73.6", "", "53.7", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.6", "84.9", "", "", "", "", "85.0"]} +{"pcdb_id": 9059, "brand_name": "GAH Heating Products", "model_name": "Thermecon 80/95", "model_qualifier": "Option C/F", "winter_efficiency_pct": 85.3, "summer_efficiency_pct": 73.6, "comparative_hot_water_efficiency_pct": 53.7, "output_kw_max": 27.8, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009059", "000051", "0", "2012/Mar/27 10:12", "GAH Heating Products", "GAH Heating Products", "Thermecon 80/95", "Option C/F", "CFO80/95", "2002", "current", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "23.4", "27.8", "", "", "85.3", "73.6", "", "53.7", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.6", "84.9", "", "", "", "", "85.0"]} +{"pcdb_id": 9060, "brand_name": "GAH Heating Products", "model_name": "Thermecon 90/120", "model_qualifier": "System B/F", "winter_efficiency_pct": 85.0, "summer_efficiency_pct": 73.3, "comparative_hot_water_efficiency_pct": 53.6, "output_kw_max": 35.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009060", "000051", "0", "2012/Mar/27 10:12", "GAH Heating Products", "GAH Heating Products", "Thermecon 90/120", "System B/F", "BFSYS90/120", "2002", "current", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "26.4", "35.2", "", "", "85.0", "73.3", "", "53.6", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.3", "84.8", "", "", "", "", "84.9"]} +{"pcdb_id": 9061, "brand_name": "GAH Heating Products", "model_name": "Thermecon 90/120", "model_qualifier": "Select B/F", "winter_efficiency_pct": 85.0, "summer_efficiency_pct": 73.3, "comparative_hot_water_efficiency_pct": 53.6, "output_kw_max": 35.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009061", "000051", "0", "2012/Mar/27 10:12", "GAH Heating Products", "GAH Heating Products", "Thermecon 90/120", "Select B/F", "BFS90/120", "2002", "current", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "26.4", "35.2", "", "", "85.0", "73.3", "", "53.6", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.3", "84.8", "", "", "", "", "84.9"]} +{"pcdb_id": 9062, "brand_name": "GAH Heating Products", "model_name": "Thermecon 90/120", "model_qualifier": "System C/F", "winter_efficiency_pct": 85.0, "summer_efficiency_pct": 73.3, "comparative_hot_water_efficiency_pct": 53.6, "output_kw_max": 35.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009062", "000051", "0", "2012/Mar/27 10:12", "GAH Heating Products", "GAH Heating Products", "Thermecon 90/120", "System C/F", "CFSYS90/120", "2002", "current", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "26.4", "35.2", "", "", "85.0", "73.3", "", "53.6", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.3", "84.8", "", "", "", "", "84.9"]} +{"pcdb_id": 9063, "brand_name": "GAH Heating Products", "model_name": "Thermecon 90/120", "model_qualifier": "Select C/F", "winter_efficiency_pct": 85.0, "summer_efficiency_pct": 73.3, "comparative_hot_water_efficiency_pct": 53.6, "output_kw_max": 35.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009063", "000051", "0", "2012/Mar/27 10:12", "GAH Heating Products", "GAH Heating Products", "Thermecon 90/120", "Select C/F", "CFS90/120", "2002", "current", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "26.4", "35.2", "", "", "85.0", "73.3", "", "53.6", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.3", "84.8", "", "", "", "", "84.9"]} +{"pcdb_id": 9064, "brand_name": "GAH Heating Products", "model_name": "Thermecon 90/120", "model_qualifier": "Option B/F", "winter_efficiency_pct": 85.0, "summer_efficiency_pct": 73.3, "comparative_hot_water_efficiency_pct": 53.6, "output_kw_max": 35.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009064", "000051", "0", "2012/Mar/27 10:12", "GAH Heating Products", "GAH Heating Products", "Thermecon 90/120", "Option B/F", "BFO90/120", "2002", "current", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "26.4", "35.2", "", "", "85.0", "73.3", "", "53.6", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.3", "84.8", "", "", "", "", "84.9"]} +{"pcdb_id": 9065, "brand_name": "GAH Heating Products", "model_name": "Thermecon 90/120", "model_qualifier": "Option C/F", "winter_efficiency_pct": 85.0, "summer_efficiency_pct": 73.3, "comparative_hot_water_efficiency_pct": 53.6, "output_kw_max": 35.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009065", "000051", "0", "2012/Mar/27 10:12", "GAH Heating Products", "GAH Heating Products", "Thermecon 90/120", "Option C/F", "CFO90/120", "2002", "current", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "26.4", "35.2", "", "", "85.0", "73.3", "", "53.6", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.3", "84.8", "", "", "", "", "84.9"]} +{"pcdb_id": 9066, "brand_name": "GAH Heating Products", "model_name": "Thermecon 100/150", "model_qualifier": "System B/F", "winter_efficiency_pct": 85.2, "summer_efficiency_pct": 73.5, "comparative_hot_water_efficiency_pct": 53.7, "output_kw_max": 43.9, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009066", "000051", "0", "2012/Mar/27 10:12", "GAH Heating Products", "GAH Heating Products", "Thermecon 100/150", "System B/F", "BFSYS100/150", "2002", "current", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "29.3", "43.9", "", "", "85.2", "73.5", "", "53.7", "", "2", "", "", "201", "1", "1", "161", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.5", "84.9", "", "", "", "", "85.0"]} +{"pcdb_id": 9067, "brand_name": "GAH Heating Products", "model_name": "Thermecon 100/150", "model_qualifier": "System C/F", "winter_efficiency_pct": 85.2, "summer_efficiency_pct": 73.5, "comparative_hot_water_efficiency_pct": 53.7, "output_kw_max": 43.9, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009067", "000051", "0", "2012/Mar/27 10:12", "GAH Heating Products", "GAH Heating Products", "Thermecon 100/150", "System C/F", "CFSYS100/150", "2002", "current", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "29.3", "43.9", "", "", "85.2", "73.5", "", "53.7", "", "2", "", "", "201", "1", "1", "161", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.5", "84.9", "", "", "", "", "85.0"]} +{"pcdb_id": 9068, "brand_name": "GAH Heating Products", "model_name": "Thermecon 100/150", "model_qualifier": "Option C/F", "winter_efficiency_pct": 85.2, "summer_efficiency_pct": 73.5, "comparative_hot_water_efficiency_pct": 53.7, "output_kw_max": 43.9, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009068", "000051", "0", "2012/Mar/27 10:12", "GAH Heating Products", "GAH Heating Products", "Thermecon 100/150", "Option C/F", "CFO100/150", "2002", "current", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "29.3", "43.9", "", "", "85.2", "73.5", "", "53.7", "", "2", "", "", "201", "1", "1", "161", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.5", "84.9", "", "", "", "", "85.0"]} +{"pcdb_id": 9069, "brand_name": "GAH Heating Products", "model_name": "Thermecon 100/150", "model_qualifier": "Select B/F", "winter_efficiency_pct": 85.2, "summer_efficiency_pct": 73.5, "comparative_hot_water_efficiency_pct": 53.7, "output_kw_max": 43.9, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009069", "000051", "0", "2012/Mar/27 10:12", "GAH Heating Products", "GAH Heating Products", "Thermecon 100/150", "Select B/F", "BFS100/150", "2002", "current", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "29.3", "43.9", "", "", "85.2", "73.5", "", "53.7", "", "2", "", "", "201", "1", "1", "161", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.5", "84.9", "", "", "", "", "85.0"]} +{"pcdb_id": 9070, "brand_name": "GAH Heating Products", "model_name": "Thermecon 100/150", "model_qualifier": "Select C/F", "winter_efficiency_pct": 85.2, "summer_efficiency_pct": 73.5, "comparative_hot_water_efficiency_pct": 53.7, "output_kw_max": 43.9, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009070", "000051", "0", "2012/Mar/27 10:12", "GAH Heating Products", "GAH Heating Products", "Thermecon 100/150", "Select C/F", "CFS100/150", "2002", "current", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "29.3", "43.9", "", "", "85.2", "73.5", "", "53.7", "", "2", "", "", "201", "1", "1", "161", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.5", "84.9", "", "", "", "", "85.0"]} +{"pcdb_id": 9071, "brand_name": "GAH Heating Products", "model_name": "Thermecon 100/150", "model_qualifier": "Option B/F", "winter_efficiency_pct": 85.2, "summer_efficiency_pct": 73.5, "comparative_hot_water_efficiency_pct": 53.7, "output_kw_max": 43.9, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009071", "000051", "0", "2012/Mar/27 10:12", "GAH Heating Products", "GAH Heating Products", "Thermecon 100/150", "Option B/F", "BFO100/150", "2002", "current", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "29.3", "43.9", "", "", "85.2", "73.5", "", "53.7", "", "2", "", "", "201", "1", "1", "161", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.5", "84.9", "", "", "", "", "85.0"]} +{"pcdb_id": 9072, "brand_name": "GAH Heating Products", "model_name": "Thermecon 140/190", "model_qualifier": "Select B/F", "winter_efficiency_pct": 85.0, "summer_efficiency_pct": 73.3, "comparative_hot_water_efficiency_pct": 53.6, "output_kw_max": 55.7, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009072", "000051", "0", "2012/Mar/27 10:12", "GAH Heating Products", "GAH Heating Products", "Thermecon 140/190", "Select B/F", "BFS140/190", "2002", "current", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "41", "55.7", "", "", "85.0", "73.3", "", "53.6", "", "2", "", "", "201", "1", "1", "151", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.3", "84.8", "", "", "", "", "84.9"]} +{"pcdb_id": 9073, "brand_name": "GAH Heating Products", "model_name": "Thermecon 140/190", "model_qualifier": "Select C/F", "winter_efficiency_pct": 85.0, "summer_efficiency_pct": 73.3, "comparative_hot_water_efficiency_pct": 53.6, "output_kw_max": 55.7, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009073", "000051", "0", "2012/Mar/27 10:12", "GAH Heating Products", "GAH Heating Products", "Thermecon 140/190", "Select C/F", "CFS140/190", "2002", "current", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "41", "55.7", "", "", "85.0", "73.3", "", "53.6", "", "2", "", "", "201", "1", "1", "151", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.3", "84.8", "", "", "", "", "84.9"]} +{"pcdb_id": 9074, "brand_name": "GAH Heating Products", "model_name": "Thermecon 140/190", "model_qualifier": "Option B/F", "winter_efficiency_pct": 85.0, "summer_efficiency_pct": 73.3, "comparative_hot_water_efficiency_pct": 53.6, "output_kw_max": 55.7, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009074", "000051", "0", "2012/Mar/27 10:12", "GAH Heating Products", "GAH Heating Products", "Thermecon 140/190", "Option B/F", "BFO140/190", "2002", "current", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "41", "55.7", "", "", "85.0", "73.3", "", "53.6", "", "2", "", "", "201", "1", "1", "151", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.3", "84.8", "", "", "", "", "84.9"]} +{"pcdb_id": 9075, "brand_name": "GAH Heating Products", "model_name": "Thermecon 140/190", "model_qualifier": "Option C/F", "winter_efficiency_pct": 85.0, "summer_efficiency_pct": 73.3, "comparative_hot_water_efficiency_pct": 53.6, "output_kw_max": 55.7, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009075", "000051", "0", "2012/Mar/27 10:12", "GAH Heating Products", "GAH Heating Products", "Thermecon 140/190", "Option C/F", "CFO140/190", "2002", "current", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "41", "55.7", "", "", "85.0", "73.3", "", "53.6", "", "2", "", "", "201", "1", "1", "151", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.3", "84.8", "", "", "", "", "84.9"]} +{"pcdb_id": 9076, "brand_name": "GAH Heating Products", "model_name": "Thermecon 190/240", "model_qualifier": "Select B/F", "winter_efficiency_pct": 85.5, "summer_efficiency_pct": 73.8, "comparative_hot_water_efficiency_pct": 53.9, "output_kw_max": null, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009076", "000051", "0", "2012/Mar/27 10:12", "GAH Heating Products", "GAH Heating Products", "Thermecon 190/240", "Select B/F", "BFS190/240", "2002", "current", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "55.7", ">70kW", "", "", "85.5", "73.8", "", "53.9", "", "2", "", "", "201", "1", "1", "151", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.8", "84.9", "", "", "", "", "85.2"]} +{"pcdb_id": 9077, "brand_name": "GAH Heating Products", "model_name": "Thermecon 190/240", "model_qualifier": "Select C/F", "winter_efficiency_pct": 85.5, "summer_efficiency_pct": 73.8, "comparative_hot_water_efficiency_pct": 53.9, "output_kw_max": null, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009077", "000051", "0", "2012/Mar/27 10:12", "GAH Heating Products", "GAH Heating Products", "Thermecon 190/240", "Select C/F", "CFS190/240", "2002", "current", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "55.7", ">70kW", "", "", "85.5", "73.8", "", "53.9", "", "2", "", "", "201", "1", "1", "151", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.8", "84.9", "", "", "", "", "85.2"]} +{"pcdb_id": 9078, "brand_name": "GAH Heating Products", "model_name": "Thermecon 190/240", "model_qualifier": "Option B/F", "winter_efficiency_pct": 85.5, "summer_efficiency_pct": 73.8, "comparative_hot_water_efficiency_pct": 53.9, "output_kw_max": null, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009078", "000051", "0", "2012/Mar/27 10:12", "GAH Heating Products", "GAH Heating Products", "Thermecon 190/240", "Option B/F", "BFO190/240", "2002", "current", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "55.7", ">70kW", "", "", "85.5", "73.8", "", "53.9", "", "2", "", "", "201", "1", "1", "151", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.8", "84.9", "", "", "", "", "85.2"]} +{"pcdb_id": 9079, "brand_name": "GAH Heating Products", "model_name": "Thermecon 190/240", "model_qualifier": "Option C/F", "winter_efficiency_pct": 85.5, "summer_efficiency_pct": 73.8, "comparative_hot_water_efficiency_pct": 53.9, "output_kw_max": null, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009079", "000051", "0", "2012/Mar/27 10:12", "GAH Heating Products", "GAH Heating Products", "Thermecon 190/240", "Option C/F", "CFO190/240", "2002", "current", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "55.7", ">70kW", "", "", "85.5", "73.8", "", "53.9", "", "2", "", "", "201", "1", "1", "151", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.8", "84.9", "", "", "", "", "85.2"]} +{"pcdb_id": 9084, "brand_name": "GAH Heating Products", "model_name": "Thermecon 40/50 W/M", "model_qualifier": "External", "winter_efficiency_pct": 86.1, "summer_efficiency_pct": 74.4, "comparative_hot_water_efficiency_pct": 54.4, "output_kw_max": 14.7, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009084", "000051", "0", "2012/Mar/27 10:12", "GAH Heating Products", "GAH Heating Products", "Thermecon 40/50 W/M", "External", "WE40/50", "2002", "current", "4", "1", "2", "1", "0", "", "", "1", "2", "2", "11.7", "14.7", "", "", "86.1", "74.4", "", "54.4", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.8", "86.0", "", "", "", "", "86.2"]} +{"pcdb_id": 9085, "brand_name": "GAH Heating Products", "model_name": "Thermecon 40/50 W/M", "model_qualifier": "Internal B/F", "winter_efficiency_pct": 86.1, "summer_efficiency_pct": 74.4, "comparative_hot_water_efficiency_pct": 54.4, "output_kw_max": 14.7, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009085", "000051", "0", "2012/Mar/27 10:12", "GAH Heating Products", "GAH Heating Products", "Thermecon 40/50 W/M", "Internal B/F", "BWI40/50", "2002", "current", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "11.7", "14.7", "", "", "86.1", "74.4", "", "54.4", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.8", "86.0", "", "", "", "", "86.2"]} +{"pcdb_id": 9086, "brand_name": "GAH Heating Products", "model_name": "Thermecon 40/50 W/M", "model_qualifier": "Internal C/F", "winter_efficiency_pct": 86.1, "summer_efficiency_pct": 74.4, "comparative_hot_water_efficiency_pct": 54.4, "output_kw_max": 14.7, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009086", "000051", "0", "2012/Mar/27 10:12", "GAH Heating Products", "GAH Heating Products", "Thermecon 40/50 W/M", "Internal C/F", "CWI40/50", "2002", "current", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "11.7", "14.7", "", "", "86.1", "74.4", "", "54.4", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.8", "86.0", "", "", "", "", "86.2"]} +{"pcdb_id": 9087, "brand_name": "GAH Heating Products", "model_name": "Thermecon 50/80 W/M", "model_qualifier": "External", "winter_efficiency_pct": 85.8, "summer_efficiency_pct": 74.1, "comparative_hot_water_efficiency_pct": 54.1, "output_kw_max": 23.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009087", "000051", "0", "2012/Mar/27 10:12", "GAH Heating Products", "GAH Heating Products", "Thermecon 50/80 W/M", "External", "WE50/80", "2002", "current", "4", "1", "2", "1", "0", "", "", "1", "2", "2", "14.7", "23.4", "", "", "85.8", "74.1", "", "54.1", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "88.4", "85.4", "", "", "", "", "85.9"]} +{"pcdb_id": 9088, "brand_name": "GAH Heating Products", "model_name": "Thermecon 50/80 W/M", "model_qualifier": "Internal C/F", "winter_efficiency_pct": 85.8, "summer_efficiency_pct": 74.1, "comparative_hot_water_efficiency_pct": 54.1, "output_kw_max": 23.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009088", "000051", "0", "2012/Mar/27 10:12", "GAH Heating Products", "GAH Heating Products", "Thermecon 50/80 W/M", "Internal C/F", "CWI50/80", "2002", "current", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "14.7", "23.4", "", "", "85.8", "74.1", "", "54.1", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "88.4", "85.4", "", "", "", "", "85.9"]} +{"pcdb_id": 9089, "brand_name": "GAH Heating Products", "model_name": "Thermecon 50/80 W/M", "model_qualifier": "Internal B/F", "winter_efficiency_pct": 85.8, "summer_efficiency_pct": 74.1, "comparative_hot_water_efficiency_pct": 54.1, "output_kw_max": 23.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009089", "000051", "0", "2012/Mar/27 10:12", "GAH Heating Products", "GAH Heating Products", "Thermecon 50/80 W/M", "Internal B/F", "BWI50/80", "2002", "current", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "14.7", "23.4", "", "", "85.8", "74.1", "", "54.1", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "88.4", "85.4", "", "", "", "", "85.9"]} +{"pcdb_id": 9091, "brand_name": "MHS Boilers", "model_name": "Strata Streamline", "model_qualifier": "31", "winter_efficiency_pct": 87.6, "summer_efficiency_pct": 78.6, "comparative_hot_water_efficiency_pct": 57.4, "output_kw_max": 29.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009091", "000024", "0", "2012/Mar/27 10:12", "MHS Boilers", "MHS Boilers", "Strata Streamline", "31", "", "2000", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "29", "29", "", "", "87.6", "78.6", "", "57.4", "", "2", "", "", "102", "1", "2", "60", "6", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "86.7", "96.3", "", "", "", "", "94.5"]} +{"pcdb_id": 9095, "brand_name": "Boulter", "model_name": "Eco-System", "model_qualifier": "12/19", "winter_efficiency_pct": 86.6, "summer_efficiency_pct": 74.9, "comparative_hot_water_efficiency_pct": 54.7, "output_kw_max": 19.0, "final_year_of_manufacture": 2005, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009095", "000041", "0", "2012/Mar/27 10:12", "Boulter Boilers", "Boulter", "Eco-System", "12/19", "", "2002", "2005", "4", "1", "1", "1", "0", "", "", "1", "3", "2", "12", "19", "", "", "86.6", "74.9", "", "54.7", "", "2", "", "", "201", "1", "1", "150", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.0", "87.0", "", "", "", "", "87.0"]} +{"pcdb_id": 9097, "brand_name": "Boulter", "model_name": "Eco-System", "model_qualifier": "19/26", "winter_efficiency_pct": 85.3, "summer_efficiency_pct": 73.6, "comparative_hot_water_efficiency_pct": 53.7, "output_kw_max": 26.0, "final_year_of_manufacture": 2005, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009097", "000041", "0", "2012/Mar/27 10:12", "Boulter Boilers", "Boulter", "Eco-System", "19/26", "", "2002", "2005", "4", "1", "1", "1", "0", "", "", "1", "3", "2", "19", "26", "", "", "85.3", "73.6", "", "53.7", "", "2", "", "", "201", "1", "1", "150", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "84.8", "85.7", "", "", "", "", "85.6"]} +{"pcdb_id": 9098, "brand_name": "Sime", "model_name": "Friendly Format 80", "model_qualifier": "", "winter_efficiency_pct": 82.0, "summer_efficiency_pct": 71.9, "comparative_hot_water_efficiency_pct": 50.6, "output_kw_max": 23.7, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009098", "000213", "0", "2018/Mar/05 14:09", "Fonderie Sime S.p.A.", "Sime", "Friendly Format 80", "", "LPG", "1998", "2018", "2", "2", "1", "2", "0", "", "", "1", "2", "2", "23.7", "23.7", "", "", "82.0", "71.9", "", "50.6", "", "2", "1", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "84.5", "81.9", "", "", "", "", "82.4"]} +{"pcdb_id": 9099, "brand_name": "Sime", "model_name": "Planet Dewy 110", "model_qualifier": "", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 56.3, "output_kw_max": 29.3, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009099", "000213", "0", "2018/Mar/05 14:27", "Fonderie Sime S.p.A.", "Sime", "Planet Dewy 110", "", "LPG", "2000", "2018", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "29.3", "29.3", "", "", "88.7", "80.1", "", "56.3", "", "2", "1", "", "104", "1", "2", "175", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.0", "98.2", "", "", "", "", "96.6"]} +{"pcdb_id": 9100, "brand_name": "Sime", "model_name": "Planet Dewy 90", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 56.1, "output_kw_max": 24.0, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009100", "000213", "0", "2018/Mar/05 14:30", "Fonderie Sime S.p.A.", "Sime", "Planet Dewy 90", "", "LPG", "2000", "2018", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24.0", "24.0", "", "", "88.4", "79.8", "", "56.1", "", "2", "1", "", "104", "1", "2", "175", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.0", "97.8", "", "", "", "", "96.1"]} +{"pcdb_id": 9101, "brand_name": "Sime", "model_name": "Format 100 C", "model_qualifier": "", "winter_efficiency_pct": 81.9, "summer_efficiency_pct": 71.8, "comparative_hot_water_efficiency_pct": 50.5, "output_kw_max": 28.8, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009101", "000213", "0", "2018/Feb/26 16:58", "Fonderie Sime S.p.A.", "Sime", "Format 100 C", "", "LPG", "2001", "2018", "2", "2", "1", "2", "0", "", "", "1", "2", "2", "28.8", "28.8", "", "", "81.9", "71.8", "", "50.5", "", "2", "1", "", "104", "1", "2", "160", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "83.8", "82.3", "", "", "", "", "82.6"]} +{"pcdb_id": 9102, "brand_name": "Sime", "model_name": "Format 80 C", "model_qualifier": "", "winter_efficiency_pct": 81.7, "summer_efficiency_pct": 71.6, "comparative_hot_water_efficiency_pct": 50.4, "output_kw_max": 23.4, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009102", "000213", "0", "2018/Feb/26 17:05", "Fonderie Sime S.p.A.", "Sime", "Format 80 C", "", "LPG", "2001", "2018", "2", "2", "1", "2", "0", "", "", "1", "2", "2", "23.4", "23.4", "", "", "81.7", "71.6", "", "50.4", "", "2", "1", "", "104", "1", "2", "150", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "83.5", "82.3", "", "", "", "", "82.6"]} +{"pcdb_id": 9103, "brand_name": "Sime", "model_name": "Super 90 MK II", "model_qualifier": "", "winter_efficiency_pct": 82.0, "summer_efficiency_pct": 71.9, "comparative_hot_water_efficiency_pct": 50.6, "output_kw_max": 23.68, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009103", "000213", "0", "2018/Mar/05 15:07", "Fonderie Sime S.p.A.", "Sime", "Super 90 MK II", "", "LPG", "2000", "2018", "2", "2", "1", "2", "0", "", "", "1", "2", "2", "23.68", "23.68", "", "", "82.0", "71.9", "", "50.6", "", "2", "1", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "84.5", "81.9", "", "", "", "", "82.4"]} +{"pcdb_id": 9104, "brand_name": "Sime", "model_name": "Friendly Format 100 E", "model_qualifier": "", "winter_efficiency_pct": 81.3, "summer_efficiency_pct": 71.2, "comparative_hot_water_efficiency_pct": 50.1, "output_kw_max": 29.0, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009104", "000213", "0", "2018/Mar/05 14:08", "Fonderie Sime S.p.A.", "Sime", "Friendly Format 100 E", "", "LPG", "1999", "2018", "2", "2", "1", "2", "0", "", "", "1", "2", "2", "29", "29", "", "", "81.3", "71.2", "", "50.1", "", "2", "1", "", "104", "1", "2", "160", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "84.7", "80.3", "", "", "", "", "81.2"]} +{"pcdb_id": 9105, "brand_name": "Sime", "model_name": "Friendly Format 80 E", "model_qualifier": "", "winter_efficiency_pct": 82.0, "summer_efficiency_pct": 71.9, "comparative_hot_water_efficiency_pct": 50.6, "output_kw_max": 23.7, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009105", "000213", "0", "2018/Mar/05 14:09", "Fonderie Sime S.p.A.", "Sime", "Friendly Format 80 E", "", "LPG", "1998", "2018", "2", "2", "1", "2", "0", "", "", "1", "2", "2", "23.7", "23.7", "", "", "82.0", "71.9", "", "50.6", "", "2", "1", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "84.5", "81.9", "", "", "", "", "82.4"]} +{"pcdb_id": 9106, "brand_name": "Sime", "model_name": "Planet Super 4 W.M..", "model_qualifier": "", "winter_efficiency_pct": 83.4, "summer_efficiency_pct": 74.3, "comparative_hot_water_efficiency_pct": 39.9, "output_kw_max": 29.5, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009106", "000213", "0", "2024/Jan/31 10:17", "Fonderie Sime S.p.A.", "Sime", "Planet Super 4 W.M..", "", "LPG", "2000", "2018", "2", "2", "1", "2", "0", "", "", "1", "2", "2", "29.5", "29.5", "", "", "83.4", "74.3", "", "39.9", "", "2", "1", "", "106", "1", "2", "180", "0", "2", "1", "0", "65", "0", "18", "2", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "86.1", "84.6", "", "", "", "", "84.9"]} +{"pcdb_id": 9108, "brand_name": "Sime", "model_name": "Planet Super 4 F.S.", "model_qualifier": "", "winter_efficiency_pct": 83.1, "summer_efficiency_pct": 74.0, "comparative_hot_water_efficiency_pct": 38.7, "output_kw_max": 29.4, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009108", "000213", "0", "2024/Jan/31 10:17", "Fonderie Sime S.p.A.", "Sime", "Planet Super 4 F.S.", "", "LPG", "2002", "2018", "2", "1", "1", "2", "0", "", "", "1", "2", "2", "29.4", "29.4", "", "", "83.1", "74.0", "", "38.7", "", "2", "1", "", "106", "1", "2", "180", "0", "2", "1", "0", "62", "0", "16", "2", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "84.5", "83.4", "", "", "", "", "83.7"]} +{"pcdb_id": 9109, "brand_name": "Sime", "model_name": "Super 105 MK II", "model_qualifier": "", "winter_efficiency_pct": 81.3, "summer_efficiency_pct": 71.2, "comparative_hot_water_efficiency_pct": 50.1, "output_kw_max": 30.5, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009109", "000213", "0", "2018/Mar/05 15:07", "Fonderie Sime S.p.A.", "Sime", "Super 105 MK II", "", "LPG", "2000", "2018", "2", "2", "1", "2", "0", "", "", "1", "2", "2", "30.5", "30.5", "", "", "81.3", "71.2", "", "50.1", "", "2", "1", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "84.7", "80.3", "", "", "", "", "81.2"]} +{"pcdb_id": 9110, "brand_name": "Sime", "model_name": "RX 37 CE IONO", "model_qualifier": "", "winter_efficiency_pct": 81.6, "summer_efficiency_pct": 71.5, "comparative_hot_water_efficiency_pct": 52.2, "output_kw_max": 39.1, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009110", "000213", "0", "2018/Mar/05 15:02", "Fonderie Sime S.p.A.", "Sime", "RX 37 CE IONO", "", "LPG", "1998", "2018", "2", "1", "1", "1", "0", "", "", "1", "1", "1", "39.1", "39.1", "", "", "81.6", "71.5", "", "52.2", "", "2", "1", "", "101", "1", "1", "16", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.5", "87.6", "", "", "", "", "86.6"]} +{"pcdb_id": 9111, "brand_name": "Sime", "model_name": "RX 48 CE IONO", "model_qualifier": "", "winter_efficiency_pct": 82.7, "summer_efficiency_pct": 72.6, "comparative_hot_water_efficiency_pct": 53.0, "output_kw_max": 48.8, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009111", "000213", "0", "2018/Mar/05 15:03", "Fonderie Sime S.p.A.", "Sime", "RX 48 CE IONO", "", "LPG", "1998", "2018", "2", "1", "1", "1", "0", "", "", "1", "1", "1", "48.8", "48.8", "", "", "82.7", "72.6", "", "53.0", "", "2", "1", "", "101", "1", "1", "16", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "84.8", "84.5", "", "", "", "", "84.6"]} +{"pcdb_id": 9112, "brand_name": "Sime", "model_name": "RX 55 CE IONO", "model_qualifier": "", "winter_efficiency_pct": 82.7, "summer_efficiency_pct": 72.6, "comparative_hot_water_efficiency_pct": 53.0, "output_kw_max": 60.7, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009112", "000213", "0", "2018/Mar/05 15:05", "Fonderie Sime S.p.A.", "Sime", "RX 55 CE IONO", "", "LPG", "1998", "2018", "2", "1", "1", "1", "0", "", "", "1", "1", "1", "60.7", "60.7", "", "", "82.7", "72.6", "", "53.0", "", "2", "1", "", "101", "1", "1", "16", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "84.8", "84.5", "", "", "", "", "84.6"]} +{"pcdb_id": 9113, "brand_name": "Firebird", "model_name": "Boilerhouse S", "model_qualifier": "50-70", "winter_efficiency_pct": 85.0, "summer_efficiency_pct": 73.3, "comparative_hot_water_efficiency_pct": 53.6, "output_kw_max": 20.52, "final_year_of_manufacture": 2013, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009113", "000047", "0", "2018/Jan/03 13:35", "Firebird Boilers", "Firebird", "Boilerhouse S", "50-70", "", "", "2013", "4", "1", "1", "1", "0", "", "", "1", "2", "1", "14.65", "20.52", "", "", "85.0", "73.3", "", "53.6", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.5", "84.6", "", "", "", "", "84.8"]} +{"pcdb_id": 9114, "brand_name": "Firebird", "model_name": "S (White Cased)", "model_qualifier": "50-70", "winter_efficiency_pct": 85.0, "summer_efficiency_pct": 73.3, "comparative_hot_water_efficiency_pct": 53.6, "output_kw_max": 20.52, "final_year_of_manufacture": 2013, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009114", "000047", "0", "2018/Jan/03 13:37", "Firebird Boilers", "Firebird", "S (White Cased)", "50-70", "", "", "2013", "4", "1", "1", "1", "0", "", "", "1", "2", "1", "14.65", "20.52", "", "", "85.0", "73.3", "", "53.6", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.5", "84.6", "", "", "", "", "84.8"]} +{"pcdb_id": 9115, "brand_name": "Firebird", "model_name": "Oylympic S", "model_qualifier": "50-82", "winter_efficiency_pct": 86.1, "summer_efficiency_pct": 74.4, "comparative_hot_water_efficiency_pct": 54.4, "output_kw_max": 24.03, "final_year_of_manufacture": 2010, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009115", "000047", "0", "2012/Mar/27 10:12", "Firebird Boilers", "Firebird", "Oylympic S", "50-82", "", "", "2010", "4", "1", "1", "1", "0", "", "", "1", "2", "1", "14.65", "24.03", "", "", "86.1", "74.4", "", "54.4", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.8", "86.4", "", "", "", "", "86.3"]} +{"pcdb_id": 9116, "brand_name": "Firebird", "model_name": "Oylympic Boilerhouse", "model_qualifier": "50-82", "winter_efficiency_pct": 86.1, "summer_efficiency_pct": 74.4, "comparative_hot_water_efficiency_pct": 54.4, "output_kw_max": 24.03, "final_year_of_manufacture": 2010, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009116", "000047", "0", "2012/Mar/27 10:12", "Firebird Boilers", "Firebird", "Oylympic Boilerhouse", "50-82", "", "", "2010", "4", "1", "1", "1", "0", "", "", "1", "2", "1", "14.65", "24.03", "", "", "86.1", "74.4", "", "54.4", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.8", "86.4", "", "", "", "", "86.3"]} +{"pcdb_id": 9117, "brand_name": "Firebird", "model_name": "Oylympic De Luxe", "model_qualifier": "50-82", "winter_efficiency_pct": 86.1, "summer_efficiency_pct": 74.4, "comparative_hot_water_efficiency_pct": 54.4, "output_kw_max": 24.03, "final_year_of_manufacture": 2010, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009117", "000047", "0", "2012/Mar/27 10:12", "Firebird Boilers", "Firebird", "Oylympic De Luxe", "50-82", "", "", "2010", "4", "1", "1", "1", "0", "", "", "1", "2", "1", "14.65", "24.03", "", "", "86.1", "74.4", "", "54.4", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.8", "86.4", "", "", "", "", "86.3"]} +{"pcdb_id": 9118, "brand_name": "Firebird", "model_name": "CombiPac", "model_qualifier": "90", "winter_efficiency_pct": 84.2, "summer_efficiency_pct": 76.1, "comparative_hot_water_efficiency_pct": 43.4, "output_kw_max": 26.38, "final_year_of_manufacture": 2013, "subsidiary_type": 0, "store_type": 1, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009118", "000047", "0", "2024/Jan/31 10:17", "Firebird Boilers", "Firebird", "CombiPac", "90", "", "1997", "2013", "4", "1", "2", "2", "0", "", "", "1", "1", "1", "26.38", "26.38", "", "", "84.2", "76.1", "", "43.4", "", "2", "", "", "203", "1", "1", "138", "0", "1", "2", "0", "25", "0", "25", "3", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.6", "85.9", "", "", "", "", "86.0"]} +{"pcdb_id": 9119, "brand_name": "Firebird", "model_name": "Boilerhouse S", "model_qualifier": "70-90", "winter_efficiency_pct": 86.1, "summer_efficiency_pct": 74.4, "comparative_hot_water_efficiency_pct": 54.4, "output_kw_max": 26.38, "final_year_of_manufacture": 2013, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009119", "000047", "0", "2018/Jan/03 13:29", "Firebird Boilers", "Firebird", "Boilerhouse S", "70-90", "", "", "2013", "4", "1", "1", "1", "0", "", "", "1", "2", "1", "20.52", "26.38", "", "", "86.1", "74.4", "", "54.4", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.8", "86.4", "", "", "", "", "86.3"]} +{"pcdb_id": 9120, "brand_name": "Firebird", "model_name": "S (White Cased)", "model_qualifier": "70-90", "winter_efficiency_pct": 86.1, "summer_efficiency_pct": 74.4, "comparative_hot_water_efficiency_pct": 54.4, "output_kw_max": 26.38, "final_year_of_manufacture": 2013, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009120", "000047", "0", "2018/Jan/03 13:30", "Firebird Boilers", "Firebird", "S (White Cased)", "70-90", "", "", "2013", "4", "1", "1", "1", "0", "", "", "1", "2", "1", "20.52", "26.38", "", "", "86.1", "74.4", "", "54.4", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.8", "86.4", "", "", "", "", "86.3"]} +{"pcdb_id": 9121, "brand_name": "Firebird", "model_name": "Sealed System", "model_qualifier": "70-90", "winter_efficiency_pct": 86.1, "summer_efficiency_pct": 74.4, "comparative_hot_water_efficiency_pct": 54.4, "output_kw_max": 26.38, "final_year_of_manufacture": 2013, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009121", "000047", "0", "2018/Jan/03 13:31", "Firebird Boilers", "Firebird", "Sealed System", "70-90", "", "", "2013", "4", "1", "1", "1", "0", "", "", "1", "2", "1", "20.52", "26.38", "", "", "86.1", "74.4", "", "54.4", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.8", "86.4", "", "", "", "", "86.3"]} +{"pcdb_id": 9122, "brand_name": "Firebird", "model_name": "Heatpac", "model_qualifier": "70-90", "winter_efficiency_pct": 86.1, "summer_efficiency_pct": 74.4, "comparative_hot_water_efficiency_pct": 54.4, "output_kw_max": 26.38, "final_year_of_manufacture": 2013, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009122", "000047", "0", "2018/Jan/03 13:31", "Firebird Boilers", "Firebird", "Heatpac", "70-90", "", "", "2013", "4", "1", "2", "1", "0", "", "", "1", "1", "1", "20.52", "26.38", "", "", "86.1", "74.4", "", "54.4", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.8", "86.4", "", "", "", "", "86.3"]} +{"pcdb_id": 9123, "brand_name": "Firebird", "model_name": "Heatpac Sealed System", "model_qualifier": "70-90", "winter_efficiency_pct": 86.1, "summer_efficiency_pct": 74.4, "comparative_hot_water_efficiency_pct": 54.4, "output_kw_max": 26.38, "final_year_of_manufacture": 2013, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009123", "000047", "0", "2018/Jan/03 13:32", "Firebird Boilers", "Firebird", "Heatpac Sealed System", "70-90", "", "", "2013", "4", "1", "2", "1", "0", "", "", "1", "1", "1", "20.52", "26.38", "", "", "86.1", "74.4", "", "54.4", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.8", "86.4", "", "", "", "", "86.3"]} +{"pcdb_id": 9124, "brand_name": "Firebird", "model_name": "Combipac", "model_qualifier": "115", "winter_efficiency_pct": 84.0, "summer_efficiency_pct": 75.9, "comparative_hot_water_efficiency_pct": 43.2, "output_kw_max": 33.7, "final_year_of_manufacture": 2010, "subsidiary_type": 0, "store_type": 1, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009124", "000047", "0", "2024/Jan/31 10:17", "Firebird Boilers", "Firebird", "Combipac", "115", "", "1997", "2010", "4", "1", "2", "2", "0", "", "", "1", "1", "1", "33.7", "33.7", "", "", "84.0", "75.9", "", "43.2", "", "2", "", "", "203", "1", "1", "138", "0", "1", "2", "0", "25", "0", "25", "3", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.1", "85.5", "", "", "", "", "85.7"]} +{"pcdb_id": 9125, "brand_name": "Firebird", "model_name": "Oylympic Boilerhouse", "model_qualifier": "90-115", "winter_efficiency_pct": 86.4, "summer_efficiency_pct": 74.7, "comparative_hot_water_efficiency_pct": 54.6, "output_kw_max": 33.7, "final_year_of_manufacture": 2010, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009125", "000047", "0", "2012/Mar/27 10:12", "Firebird Boilers", "Firebird", "Oylympic Boilerhouse", "90-115", "", "1997", "2010", "4", "1", "1", "1", "0", "", "", "1", "2", "1", "26.38", "33.70", "", "", "86.4", "74.7", "", "54.6", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.4", "86.7", "", "", "", "", "86.6"]} +{"pcdb_id": 9126, "brand_name": "Firebird", "model_name": "Oylympic S", "model_qualifier": "90-115", "winter_efficiency_pct": 86.4, "summer_efficiency_pct": 74.7, "comparative_hot_water_efficiency_pct": 54.6, "output_kw_max": 33.7, "final_year_of_manufacture": 2010, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009126", "000047", "0", "2012/Mar/27 10:12", "Firebird Boilers", "Firebird", "Oylympic S", "90-115", "", "1997", "2010", "4", "1", "1", "1", "0", "", "", "1", "2", "1", "26.38", "33.70", "", "", "86.4", "74.7", "", "54.6", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.4", "86.7", "", "", "", "", "86.6"]} +{"pcdb_id": 9127, "brand_name": "Firebird", "model_name": "Heatpac S", "model_qualifier": "70-90", "winter_efficiency_pct": 86.1, "summer_efficiency_pct": 74.4, "comparative_hot_water_efficiency_pct": 54.4, "output_kw_max": 26.38, "final_year_of_manufacture": 2013, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009127", "000047", "0", "2018/Jan/03 13:34", "Firebird Boilers", "Firebird", "Heatpac S", "70-90", "", "", "2013", "4", "1", "2", "1", "0", "", "", "1", "1", "1", "20.52", "26.38", "", "", "86.1", "74.4", "", "54.4", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.8", "86.4", "", "", "", "", "86.3"]} +{"pcdb_id": 9128, "brand_name": "Broag Remeha", "model_name": "Selecta", "model_qualifier": "Selecta Combi", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 56.3, "output_kw_max": 16.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009128", "000006", "0", "2006/Jan/17 12:31", "Remeha", "Broag Remeha", "Selecta", "Selecta Combi", "0063BL3537", "2000", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "16", "16", "", "", "88.7", "80.1", "", "56.3", "", "2", "", "", "104", "1", "2", "130", "8", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "98.5", "", "", "", "", "96.5"]} +{"pcdb_id": 9129, "brand_name": "Broag Remeha", "model_name": "Selecta", "model_qualifier": "Selecta System", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 16.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009129", "000006", "0", "2012/Mar/27 10:12", "Remeha", "Broag Remeha", "Selecta", "Selecta System", "0063BL3537", "2000", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "16", "16", "", "", "88.7", "79.7", "", "58.2", "", "2", "", "", "102", "1", "2", "130", "8", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "98.5", "", "", "", "", "96.5"]} +{"pcdb_id": 9130, "brand_name": "Vokera", "model_name": "Mynute 12e", "model_qualifier": "", "winter_efficiency_pct": 80.1, "summer_efficiency_pct": 70.0, "comparative_hot_water_efficiency_pct": 51.1, "output_kw_max": 12.0, "final_year_of_manufacture": 2010, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009130", "000011", "0", "2012/Mar/27 10:12", "Vokera", "Vokera", "Mynute 12e", "", "141", "2002", "2010", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "7.4", "12.0", "", "", "80.1", "70.0", "", "51.1", "", "2", "", "", "101", "1", "1", "125", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "83.3", "80.5", "", "", "", "", "81.0"]} +{"pcdb_id": 9131, "brand_name": "Vokera", "model_name": "Mynute 16e", "model_qualifier": "", "winter_efficiency_pct": 80.5, "summer_efficiency_pct": 70.4, "comparative_hot_water_efficiency_pct": 51.4, "output_kw_max": 16.0, "final_year_of_manufacture": 2010, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009131", "000011", "0", "2012/Mar/27 10:12", "Vokera", "Vokera", "Mynute 16e", "", "143", "2002", "2010", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "12", "16.0", "", "", "80.5", "70.4", "", "51.4", "", "2", "", "", "101", "1", "1", "125", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "83.4", "81.4", "", "", "", "", "81.8"]} +{"pcdb_id": 9133, "brand_name": "NST", "model_name": "Sogno Eli 8-22", "model_qualifier": "M", "winter_efficiency_pct": 83.2, "summer_efficiency_pct": 73.1, "comparative_hot_water_efficiency_pct": 51.4, "output_kw_max": 22.42, "final_year_of_manufacture": 2003, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009133", "000216", "0", "2006/Jan/17 12:55", "NST Nvovi Sistemi Termotecnici", "NST", "Sogno Eli 8-22", "M", "", "1997", "2003", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "22.42", "22.42", "", "", "83.2", "73.1", "", "51.4", "", "2", "", "", "104", "1", "2", "68", "40", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "86.3", "86.0", "", "", "", "", "86.0"]} +{"pcdb_id": 9145, "brand_name": "Turkington Engineering", "model_name": "Turco Trojan", "model_qualifier": "50/90", "winter_efficiency_pct": 86.4, "summer_efficiency_pct": 74.7, "comparative_hot_water_efficiency_pct": 54.6, "output_kw_max": 26.37, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009145", "000218", "0", "2012/Mar/27 10:12", "Turkington Engineering", "Turkington Engineering", "Turco Trojan", "50/90", "", "1996", "current", "4", "1", "2", "1", "0", "", "", "1", "1", "1", "14.65", "26.37", "", "", "86.4", "74.7", "", "54.6", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.7", "87.7", "", "", "", "", "87.3"]} +{"pcdb_id": 9146, "brand_name": "Turkington Engineering", "model_name": "Turco Trojan Boiler House", "model_qualifier": "50/90", "winter_efficiency_pct": 86.4, "summer_efficiency_pct": 74.7, "comparative_hot_water_efficiency_pct": 54.6, "output_kw_max": 26.37, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009146", "000218", "0", "2012/Mar/27 10:12", "Turkington Engineering", "Turkington Engineering", "Turco Trojan Boiler House", "50/90", "", "1996", "current", "4", "1", "2", "1", "0", "", "", "1", "1", "1", "14.65", "26.37", "", "", "86.4", "74.7", "", "54.6", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.7", "87.7", "", "", "", "", "87.3"]} +{"pcdb_id": 9147, "brand_name": "Turkington Engineering", "model_name": "Turco Trojan White Cased", "model_qualifier": "50/90", "winter_efficiency_pct": 86.4, "summer_efficiency_pct": 74.7, "comparative_hot_water_efficiency_pct": 54.6, "output_kw_max": 26.37, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009147", "000218", "0", "2012/Mar/27 10:12", "Turkington Engineering", "Turkington Engineering", "Turco Trojan White Cased", "50/90", "", "1996", "current", "4", "1", "2", "1", "0", "", "", "1", "1", "1", "14.65", "26.37", "", "", "86.4", "74.7", "", "54.6", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.7", "87.7", "", "", "", "", "87.3"]} +{"pcdb_id": 9148, "brand_name": "Turkington Engineering", "model_name": "Turco Trojan Outdoor", "model_qualifier": "50/90", "winter_efficiency_pct": 86.4, "summer_efficiency_pct": 74.7, "comparative_hot_water_efficiency_pct": 54.6, "output_kw_max": 26.37, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009148", "000218", "0", "2012/Mar/27 10:12", "Turkington Engineering", "Turkington Engineering", "Turco Trojan Outdoor", "50/90", "", "1996", "current", "4", "1", "2", "1", "0", "", "", "1", "1", "1", "14.65", "26.37", "", "", "86.4", "74.7", "", "54.6", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.7", "87.7", "", "", "", "", "87.3"]} +{"pcdb_id": 9149, "brand_name": "Turkington Engineering", "model_name": "Eurocal White Cased Utility", "model_qualifier": "70/90", "winter_efficiency_pct": 86.4, "summer_efficiency_pct": 74.7, "comparative_hot_water_efficiency_pct": 54.6, "output_kw_max": 20.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009149", "000218", "0", "2012/Mar/27 10:12", "Turkington Engineering", "Turkington Engineering", "Eurocal White Cased Utility", "70/90", "", "1996", "current", "4", "1", "2", "1", "0", "", "", "1", "1", "1", "14.65", "20.50", "", "", "86.4", "74.7", "", "54.6", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.7", "87.7", "", "", "", "", "87.3"]} +{"pcdb_id": 9150, "brand_name": "Turkington Engineering", "model_name": "Turco Trojan Boiler House", "model_qualifier": "50/70", "winter_efficiency_pct": 86.4, "summer_efficiency_pct": 74.7, "comparative_hot_water_efficiency_pct": 54.6, "output_kw_max": 20.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009150", "000218", "0", "2012/Mar/27 10:12", "Turkington Engineering", "Turkington Engineering", "Turco Trojan Boiler House", "50/70", "", "1996", "current", "4", "1", "2", "1", "0", "", "", "1", "1", "1", "14.65", "20.50", "", "", "86.4", "74.7", "", "54.6", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.7", "87.7", "", "", "", "", "87.3"]} +{"pcdb_id": 9151, "brand_name": "Turkington Engineering", "model_name": "Eurocal White Cased Utility", "model_qualifier": "50/70", "winter_efficiency_pct": 86.4, "summer_efficiency_pct": 74.7, "comparative_hot_water_efficiency_pct": 54.6, "output_kw_max": 20.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009151", "000218", "0", "2012/Mar/27 10:12", "Turkington Engineering", "Turkington Engineering", "Eurocal White Cased Utility", "50/70", "", "1996", "current", "4", "1", "2", "1", "0", "", "", "1", "1", "1", "14.65", "20.50", "", "", "86.4", "74.7", "", "54.6", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.7", "87.7", "", "", "", "", "87.3"]} +{"pcdb_id": 9152, "brand_name": "HRM Boilers", "model_name": "Wallstar 12/15", "model_qualifier": "11", "winter_efficiency_pct": 85.3, "summer_efficiency_pct": 73.6, "comparative_hot_water_efficiency_pct": 53.8, "output_kw_max": 15.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009152", "000098", "0", "2012/Mar/27 10:12", "HRM Boilers", "HRM Boilers", "Wallstar 12/15", "11", "20020422", "2002", "current", "4", "2", "1", "1", "0", "", "", "1", "2", "2", "12", "15", "", "", "85.3", "73.6", "", "53.8", "", "2", "", "", "201", "1", "1", "140", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.3", "85.4", "", "", "", "", "85.3"]} +{"pcdb_id": 9153, "brand_name": "Boulter", "model_name": "Camray 5", "model_qualifier": "200/240", "winter_efficiency_pct": 85.5, "summer_efficiency_pct": 73.8, "comparative_hot_water_efficiency_pct": 53.9, "output_kw_max": null, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009153", "000041", "0", "2012/Mar/27 10:12", "Boulter Boilers", "Boulter", "Camray 5", "200/240", "", "2002", "current", "4", "1", "1", "1", "0", "", "", "1", "3", "2", "58.6", ">70kW", "", "", "85.5", "73.8", "", "53.9", "", "2", "", "", "201", "1", "1", "150", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.0", "86.1", "", "", "", "", "85.9"]} +{"pcdb_id": 9155, "brand_name": "Ideal", "model_name": "Mini S28", "model_qualifier": "28kW System Boiler", "winter_efficiency_pct": 79.4, "summer_efficiency_pct": 68.7, "comparative_hot_water_efficiency_pct": 50.2, "output_kw_max": 28.0, "final_year_of_manufacture": 2009, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009155", "000008", "0", "2018/Oct/15 12:00", "Savio Caldaie SpA", "Ideal", "Mini S28", "28kW System Boiler", "0694BM3420", "2002", "2009", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "28", "28", "", "", "79.4", "68.7", "", "50.2", "", "2", "", "", "102", "1", "2", "170", "7", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.2", "78.6", "", "", "", "", "79.3"]} +{"pcdb_id": 9156, "brand_name": "Ideal", "model_name": "Mini S24", "model_qualifier": "24kW System Boiler", "winter_efficiency_pct": 79.3, "summer_efficiency_pct": 68.6, "comparative_hot_water_efficiency_pct": 50.1, "output_kw_max": 24.3, "final_year_of_manufacture": 2009, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009156", "000008", "0", "2018/Oct/15 12:00", "Savio Caldaie SpA", "Ideal", "Mini S24", "24kW System Boiler", "0694BM3420", "2002", "2009", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "24.3", "24.3", "", "", "79.3", "68.6", "", "50.1", "", "2", "", "", "102", "1", "2", "150", "7", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.3", "78.4", "", "", "", "", "79.1"]} +{"pcdb_id": 9157, "brand_name": "Ideal", "model_name": "Mini C28", "model_qualifier": "28kW Combi Boiler", "winter_efficiency_pct": 79.2, "summer_efficiency_pct": 69.1, "comparative_hot_water_efficiency_pct": 48.6, "output_kw_max": 28.0, "final_year_of_manufacture": 2004, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009157", "000008", "0", "2018/Oct/15 12:00", "Savio Caldaie SpA", "Ideal", "Mini C28", "28kW Combi Boiler", "0694BM3420", "2002", "2004", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "28", "28", "", "", "79.2", "69.1", "", "48.6", "", "2", "", "", "104", "1", "2", "170", "7", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.2", "78.6", "", "", "", "", "79.3"]} +{"pcdb_id": 9158, "brand_name": "Ideal", "model_name": "Mini C24", "model_qualifier": "24kW Combi Boiler", "winter_efficiency_pct": 79.1, "summer_efficiency_pct": 69.0, "comparative_hot_water_efficiency_pct": 48.5, "output_kw_max": 24.3, "final_year_of_manufacture": 2004, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009158", "000008", "0", "2018/Oct/15 12:00", "Savio Caldaie SpA", "Ideal", "Mini C24", "24kW Combi Boiler", "0694BM3420", "2002", "2004", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "24.3", "24.3", "", "", "79.1", "69.0", "", "48.5", "", "2", "", "", "104", "1", "2", "150", "7", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "0", "0004", "", "", "", "", "", "", "", "", "82.3", "78.4", "", "", "", "", "79.1"]} +{"pcdb_id": 9159, "brand_name": "Europa", "model_name": "24", "model_qualifier": "24kW Combi Boiler", "winter_efficiency_pct": 79.8, "summer_efficiency_pct": 69.7, "comparative_hot_water_efficiency_pct": 49.0, "output_kw_max": 24.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009159", "000008", "0", "2002/May/13 11:14", "Unical AG SpA", "Europa", "24", "24kW Combi Boiler", "49AU2867", "2002", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "24.3", "24.3", "", "", "79.8", "69.7", "", "49.0", "", "2", "", "", "104", "1", "2", "137", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.5", "80.5", "", "", "", "", "80.6"]} +{"pcdb_id": 9160, "brand_name": "Europa", "model_name": "28", "model_qualifier": "28 kW Combi Boiler", "winter_efficiency_pct": 80.7, "summer_efficiency_pct": 70.6, "comparative_hot_water_efficiency_pct": 49.7, "output_kw_max": 28.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009160", "000008", "0", "2002/May/13 11:14", "Unical AG SpA", "Europa", "28", "28 kW Combi Boiler", "49AU2949", "2002", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "28", "28", "", "", "80.7", "70.6", "", "49.7", "", "2", "", "", "104", "1", "2", "137", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.5", "81.4", "", "", "", "", "81.6"]} +{"pcdb_id": 9161, "brand_name": "Boxer", "model_name": "C24", "model_qualifier": "24kW Combi Boiler", "winter_efficiency_pct": 79.8, "summer_efficiency_pct": 69.7, "comparative_hot_water_efficiency_pct": 49.0, "output_kw_max": 24.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009161", "000008", "0", "2002/May/13 11:15", "Unical AG SpA", "Boxer", "C24", "24kW Combi Boiler", "49AU2867", "2002", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "24.3", "24.3", "", "", "79.8", "69.7", "", "49.0", "", "2", "", "", "104", "1", "2", "137", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.5", "80.5", "", "", "", "", "80.6"]} +{"pcdb_id": 9162, "brand_name": "Boxer", "model_name": "C28", "model_qualifier": "28kW Combi Boiler", "winter_efficiency_pct": 79.8, "summer_efficiency_pct": 69.7, "comparative_hot_water_efficiency_pct": 49.0, "output_kw_max": 24.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009162", "000008", "0", "2002/May/13 11:15", "Unical AG SpA", "Boxer", "C28", "28kW Combi Boiler", "49AU2867", "2002", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "24.3", "24.3", "", "", "79.8", "69.7", "", "49.0", "", "2", "", "", "104", "1", "2", "137", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.6", "80.5", "", "", "", "", "80.7"]} +{"pcdb_id": 9163, "brand_name": "Geminox", "model_name": "THR 2-13C", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 14.7, "final_year_of_manufacture": 2006, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009163", "000212", "0", "2012/Mar/27 10:12", "Geminox SA", "Geminox", "THR 2-13C", "", "2-13C", "1997", "2006", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "14.7", "14.7", "", "", "88.3", "79.3", "", "58.0", "", "2", "", "", "102", "1", "2", "90", "15", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "97.8", "", "", "", "", "95.9"]} +{"pcdb_id": 9170, "brand_name": "Broag Remeha", "model_name": "Selecta", "model_qualifier": "Selecta System", "winter_efficiency_pct": 89.7, "summer_efficiency_pct": 80.7, "comparative_hot_water_efficiency_pct": 58.9, "output_kw_max": 16.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009170", "000006", "0", "2012/Mar/27 10:12", "Remeha", "Broag Remeha", "Selecta", "Selecta System", "0063BL3537", "2000", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "16", "16", "", "", "89.7", "80.7", "", "58.9", "", "2", "1", "", "102", "1", "2", "130", "8", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.9", "100.7", "", "", "", "", "98.6"]} +{"pcdb_id": 9171, "brand_name": "Broag Remeha", "model_name": "Selecta", "model_qualifier": "Selecta Combi", "winter_efficiency_pct": 89.7, "summer_efficiency_pct": 81.1, "comparative_hot_water_efficiency_pct": 57.0, "output_kw_max": 16.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009171", "000006", "0", "2006/Jan/17 12:31", "Remeha", "Broag Remeha", "Selecta", "Selecta Combi", "0063BL3537", "2000", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "16", "16", "", "", "89.7", "81.1", "", "57.0", "", "2", "1", "", "104", "1", "2", "130", "8", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.9", "100.7", "", "", "", "", "98.6"]} +{"pcdb_id": 9177, "brand_name": "Ravenheat", "model_name": "Little Star LS 80", "model_qualifier": "", "winter_efficiency_pct": 80.5, "summer_efficiency_pct": 70.4, "comparative_hot_water_efficiency_pct": 49.5, "output_kw_max": 24.1, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009177", "000026", "0", "2006/Jan/17 12:31", "Ravenheat", "Ravenheat", "Little Star LS 80", "", "", "2002", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "24.1", "24.1", "", "", "80.5", "70.4", "", "49.5", "", "2", "", "", "104", "1", "2", "150", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "", "", "0004", "", "", "", "", "", "", "", "", "83.3", "80.5", "", "", "", "", "81.1"]} +{"pcdb_id": 9178, "brand_name": "Ravenheat", "model_name": "Little Star LS 80 (T)", "model_qualifier": "", "winter_efficiency_pct": 80.5, "summer_efficiency_pct": 70.4, "comparative_hot_water_efficiency_pct": 49.5, "output_kw_max": 24.1, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009178", "000026", "0", "2006/Jan/17 12:31", "Ravenheat", "Ravenheat", "Little Star LS 80 (T)", "", "", "2002", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "24.1", "24.1", "", "", "80.5", "70.4", "", "49.5", "", "2", "", "", "104", "1", "2", "150", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "", "", "0004", "", "", "", "", "", "", "", "", "83.3", "80.5", "", "", "", "", "81.1"]} +{"pcdb_id": 9179, "brand_name": "Sime", "model_name": "Superior 40 Ci", "model_qualifier": "", "winter_efficiency_pct": 79.9, "summer_efficiency_pct": 69.8, "comparative_hot_water_efficiency_pct": 51.0, "output_kw_max": 11.8, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009179", "000213", "0", "2018/Mar/05 15:08", "Fonderie Sime S.p.A.", "Sime", "Superior 40 Ci", "", "", "2002", "2018", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "8.8", "11.8", "", "", "79.9", "69.8", "", "51.0", "", "2", "", "", "101", "1", "1", "55", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.9", "81.1", "", "", "", "", "81.2"]} +{"pcdb_id": 9180, "brand_name": "Sime", "model_name": "Superior 50 Ci", "model_qualifier": "", "winter_efficiency_pct": 80.9, "summer_efficiency_pct": 70.8, "comparative_hot_water_efficiency_pct": 51.7, "output_kw_max": 14.6, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009180", "000213", "0", "2018/Mar/05 15:10", "Fonderie Sime S.p.A.", "Sime", "Superior 50 Ci", "", "", "2002", "2018", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "11.9", "14.6", "", "", "80.9", "70.8", "", "51.7", "", "2", "", "", "101", "1", "1", "55", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.7", "82.4", "", "", "", "", "82.4"]} +{"pcdb_id": 9181, "brand_name": "Sime", "model_name": "Superior 60 Ci", "model_qualifier": "", "winter_efficiency_pct": 80.3, "summer_efficiency_pct": 70.2, "comparative_hot_water_efficiency_pct": 51.3, "output_kw_max": 17.5, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009181", "000213", "0", "2018/Mar/05 15:11", "Fonderie Sime S.p.A.", "Sime", "Superior 60 Ci", "", "", "2002", "2018", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "14.7", "17.5", "", "", "80.3", "70.2", "", "51.3", "", "2", "", "", "101", "1", "1", "60", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.8", "82.0", "", "", "", "", "82.0"]} +{"pcdb_id": 9182, "brand_name": "Sime", "model_name": "Superior 80 Ci", "model_qualifier": "", "winter_efficiency_pct": 79.5, "summer_efficiency_pct": 69.4, "comparative_hot_water_efficiency_pct": 50.7, "output_kw_max": 23.4, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009182", "000213", "0", "2018/Mar/05 15:13", "Fonderie Sime S.p.A.", "Sime", "Superior 80 Ci", "", "", "2002", "2018", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "17.6", "23.4", "", "", "79.5", "69.4", "", "50.7", "", "2", "", "", "101", "1", "1", "65", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.2", "81.0", "", "", "", "", "81.0"]} +{"pcdb_id": 9183, "brand_name": "Sime", "model_name": "Superior 40 Ci EI", "model_qualifier": "", "winter_efficiency_pct": 79.9, "summer_efficiency_pct": 69.8, "comparative_hot_water_efficiency_pct": 51.0, "output_kw_max": 11.8, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009183", "000213", "0", "2018/Mar/05 15:09", "Fonderie Sime S.p.A.", "Sime", "Superior 40 Ci EI", "", "", "2002", "2018", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "8.8", "11.8", "", "", "79.9", "69.8", "", "51.0", "", "2", "", "", "101", "1", "1", "55", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.9", "81.1", "", "", "", "", "81.2"]} +{"pcdb_id": 9184, "brand_name": "Sime", "model_name": "Superior 50 Ci EI", "model_qualifier": "", "winter_efficiency_pct": 80.9, "summer_efficiency_pct": 70.8, "comparative_hot_water_efficiency_pct": 51.7, "output_kw_max": 14.6, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009184", "000213", "0", "2018/Mar/05 15:10", "Fonderie Sime S.p.A.", "Sime", "Superior 50 Ci EI", "", "", "2002", "2018", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "11.9", "14.6", "", "", "80.9", "70.8", "", "51.7", "", "2", "", "", "101", "1", "1", "55", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.7", "82.4", "", "", "", "", "82.4"]} +{"pcdb_id": 9186, "brand_name": "Sime", "model_name": "Superior 60 Ci EI", "model_qualifier": "", "winter_efficiency_pct": 80.3, "summer_efficiency_pct": 70.2, "comparative_hot_water_efficiency_pct": 51.3, "output_kw_max": 17.5, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009186", "000213", "0", "2018/Mar/05 15:12", "Fonderie Sime S.p.A.", "Sime", "Superior 60 Ci EI", "", "", "2002", "2018", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "14.7", "17.5", "", "", "80.3", "70.2", "", "51.3", "", "2", "", "", "101", "1", "1", "60", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.8", "82.0", "", "", "", "", "82.0"]} +{"pcdb_id": 9187, "brand_name": "Sime", "model_name": "Superior 80 Ci EI", "model_qualifier": "", "winter_efficiency_pct": 79.5, "summer_efficiency_pct": 69.4, "comparative_hot_water_efficiency_pct": 50.7, "output_kw_max": 23.4, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009187", "000213", "0", "2018/Mar/05 15:14", "Fonderie Sime S.p.A.", "Sime", "Superior 80 Ci EI", "", "", "2002", "2018", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "17.6", "23.4", "", "", "79.5", "69.4", "", "50.7", "", "2", "", "", "101", "1", "1", "65", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.2", "81.0", "", "", "", "", "81.0"]} +{"pcdb_id": 9188, "brand_name": "Vokera", "model_name": "Lineamax", "model_qualifier": "", "winter_efficiency_pct": 78.9, "summer_efficiency_pct": 69.8, "comparative_hot_water_efficiency_pct": 37.0, "output_kw_max": 28.0, "final_year_of_manufacture": 2010, "subsidiary_type": 0, "store_type": 1, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009188", "000011", "0", "2024/Jan/31 10:17", "Vokera", "Vokera", "Lineamax", "", "47-094-30", "1999", "2010", "1", "1", "1", "2", "0", "", "", "1", "2", "2", "28", "28", "", "", "78.9", "69.8", "", "37.0", "", "2", "", "", "106", "1", "2", "150", "0", "1", "1", "0", "58", "0", "25", "3", "70", "1.0", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.7", "77.8", "", "", "", "", "78.6"]} +{"pcdb_id": 9189, "brand_name": "Warmflow", "model_name": "Goldbird", "model_qualifier": "150/200GB", "winter_efficiency_pct": 85.8, "summer_efficiency_pct": 74.1, "comparative_hot_water_efficiency_pct": 54.1, "output_kw_max": 58.62, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009189", "000063", "0", "2012/Mar/27 10:12", "Warmflow Engineering", "Warmflow", "Goldbird", "150/200GB", "", "2002", "current", "4", "1", "2", "1", "0", "", "", "1", "2", "2", "44", "58.62", "", "", "85.8", "74.1", "", "54.1", "", "2", "", "", "201", "1", "1", "300", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "84.8", "86.8", "", "", "", "", "86.4"]} +{"pcdb_id": 9190, "brand_name": "Warmflow", "model_name": "Whitebird", "model_qualifier": "150/200WB", "winter_efficiency_pct": 85.8, "summer_efficiency_pct": 74.1, "comparative_hot_water_efficiency_pct": 54.1, "output_kw_max": 58.62, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009190", "000063", "0", "2012/Mar/27 10:12", "Warmflow Engineering", "Warmflow", "Whitebird", "150/200WB", "", "2002", "current", "4", "1", "2", "1", "0", "", "", "1", "2", "2", "44", "58.62", "", "", "85.8", "74.1", "", "54.1", "", "2", "", "", "201", "1", "1", "300", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "84.8", "86.8", "", "", "", "", "86.4"]} +{"pcdb_id": 9191, "brand_name": "Warmflow", "model_name": "Bluebird", "model_qualifier": "150/200BB", "winter_efficiency_pct": 85.8, "summer_efficiency_pct": 74.1, "comparative_hot_water_efficiency_pct": 54.1, "output_kw_max": 58.62, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009191", "000063", "0", "2012/Mar/27 10:12", "Warmflow Engineering", "Warmflow", "Bluebird", "150/200BB", "", "2002", "current", "4", "1", "2", "1", "0", "", "", "1", "2", "2", "44", "58.62", "", "", "85.8", "74.1", "", "54.1", "", "2", "", "", "201", "1", "1", "300", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "84.8", "86.8", "", "", "", "", "86.4"]} +{"pcdb_id": 9192, "brand_name": "Worcester", "model_name": "28 SI II", "model_qualifier": "RSF", "winter_efficiency_pct": 79.3, "summer_efficiency_pct": 69.2, "comparative_hot_water_efficiency_pct": 48.6, "output_kw_max": 8.1, "final_year_of_manufacture": 2005, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009192", "000035", "0", "2020/Sep/04 08:04", "Worcester Heat Systems", "Worcester", "28 SI II", "RSF", "47-311-67", "2002", "2005", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "8.1", "8.1", "", "", "79.3", "69.2", "", "48.6", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.3", "78.7", "", "", "", "", "79.3"]} +{"pcdb_id": 9193, "brand_name": "Worcester", "model_name": "28 SI II", "model_qualifier": "RSF", "winter_efficiency_pct": 80.9, "summer_efficiency_pct": 70.8, "comparative_hot_water_efficiency_pct": 49.8, "output_kw_max": 8.1, "final_year_of_manufacture": 2005, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009193", "000035", "0", "2020/Sep/04 08:04", "Worcester Heat Systems", "Worcester", "28 SI II", "RSF", "47-311-68", "2002", "2005", "2", "2", "1", "2", "0", "", "", "1", "2", "2", "8.1", "8.1", "", "", "80.9", "70.8", "", "49.8", "", "2", "0", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "84.5", "79.6", "", "", "", "", "80.5"]} +{"pcdb_id": 9194, "brand_name": "Worcester", "model_name": "24 SI II", "model_qualifier": "RSF", "winter_efficiency_pct": 81.4, "summer_efficiency_pct": 71.3, "comparative_hot_water_efficiency_pct": 50.1, "output_kw_max": 24.0, "final_year_of_manufacture": 2005, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009194", "000035", "0", "2020/Sep/04 08:04", "Worcester Heat Systems", "Worcester", "24 SI II", "RSF", "47-311-66", "2002", "2005", "2", "2", "1", "2", "0", "", "", "1", "2", "2", "24", "24", "", "", "81.4", "71.3", "", "50.1", "", "2", "0", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "84.1", "81.0", "", "", "", "", "81.6"]} +{"pcdb_id": 9195, "brand_name": "Worcester", "model_name": "24 SI II", "model_qualifier": "RSF", "winter_efficiency_pct": 79.0, "summer_efficiency_pct": 68.9, "comparative_hot_water_efficiency_pct": 48.4, "output_kw_max": 24.0, "final_year_of_manufacture": 2005, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009195", "000035", "0", "2020/Sep/04 08:04", "Worcester Heat Systems", "Worcester", "24 SI II", "RSF", "47-311-65", "2002", "2005", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "24", "24", "", "", "79.0", "68.9", "", "48.4", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.8", "78.6", "", "", "", "", "79.2"]} +{"pcdb_id": 9196, "brand_name": "Fagor Electrodomesticos S.Coop", "model_name": "FEB-20E Ecoplus", "model_qualifier": "FEB-20EUK N", "winter_efficiency_pct": 80.4, "summer_efficiency_pct": 70.3, "comparative_hot_water_efficiency_pct": 49.4, "output_kw_max": 23.26, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009196", "000219", "0", "2013/Jun/25 14:28", "Fagor Electrodomesticos S.Coop", "Fagor Electrodomesticos S.Coop", "FEB-20E Ecoplus", "FEB-20EUK N", "", "1999", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "23.26", "23.26", "", "", "80.4", "70.3", "", "49.4", "", "2", "", "", "104", "1", "2", "30", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "83.2", "80.3", "", "", "", "", "80.8"]} +{"pcdb_id": 9197, "brand_name": "Fagor Electrodomesticos S.Coop", "model_name": "FEB-20E Ecoplus", "model_qualifier": "FEB-20EUK GLP", "winter_efficiency_pct": 81.9, "summer_efficiency_pct": 71.8, "comparative_hot_water_efficiency_pct": 50.5, "output_kw_max": 23.26, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009197", "000219", "0", "2013/Jun/25 14:28", "Fagor Electrodomesticos S.Coop", "Fagor Electrodomesticos S.Coop", "FEB-20E Ecoplus", "FEB-20EUK GLP", "", "1999", "current", "2", "2", "1", "2", "0", "", "", "1", "2", "2", "23.26", "23.26", "", "", "81.9", "71.8", "", "50.5", "", "2", "0", "", "104", "1", "2", "30", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "84.2", "82.0", "", "", "", "", "82.4"]} +{"pcdb_id": 9198, "brand_name": "DD Heating", "model_name": "Mikrofill", "model_qualifier": "Ethos 24 C", "winter_efficiency_pct": 79.5, "summer_efficiency_pct": 69.4, "comparative_hot_water_efficiency_pct": 48.8, "output_kw_max": 23.17, "final_year_of_manufacture": 2004, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009198", "000215", "0", "2011/Aug/31 10:45", "Turk Demir Dokum Fab AS", "DD Heating", "Mikrofill", "Ethos 24 C", "", "2001", "2004", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "23.17", "23.17", "", "", "79.5", "69.4", "", "48.8", "", "2", "", "", "104", "1", "2", "170", "17", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.5", "79.8", "", "", "", "", "80.2"]} +{"pcdb_id": 9199, "brand_name": "Worcester", "model_name": "Greenstar 29HE Conventional", "model_qualifier": "ZB 7-29", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 29.0, "final_year_of_manufacture": 2005, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009199", "000035", "0", "2020/Sep/04 08:04", "Worcester Heat Systems", "Worcester", "Greenstar 29HE Conventional", "ZB 7-29", "4131156", "2002", "2005", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "29", "29", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.9", "96.5", "", "", "", "", "95.1"]} +{"pcdb_id": 9200, "brand_name": "Potterton", "model_name": "Osprey 2", "model_qualifier": "CFL 180", "winter_efficiency_pct": 79.6, "summer_efficiency_pct": 69.5, "comparative_hot_water_efficiency_pct": 50.8, "output_kw_max": 52.8, "final_year_of_manufacture": 2005, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009200", "000005", "0", "2012/Mar/27 10:12", "Baxi Potterton", "Potterton", "Osprey 2", "CFL 180", "GC No. 41-590-56", "2002", "2005", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "52.8", "52.8", "", "", "79.6", "69.5", "", "50.8", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.5", "80.8", "", "", "", "", "81.0"]} +{"pcdb_id": 9201, "brand_name": "Potterton", "model_name": "Osprey 2", "model_qualifier": "CFL 220", "winter_efficiency_pct": 78.9, "summer_efficiency_pct": 68.8, "comparative_hot_water_efficiency_pct": 50.2, "output_kw_max": 64.5, "final_year_of_manufacture": 2006, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009201", "000005", "0", "2012/Mar/27 10:12", "Baxi Potterton", "Potterton", "Osprey 2", "CFL 220", "GC No. 41-590-57", "2002", "2006", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "64.5", "64.5", "", "", "78.9", "68.8", "", "50.2", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "80.6", "80.3", "", "", "", "", "80.3"]} +{"pcdb_id": 9202, "brand_name": "Potterton", "model_name": "Osprey 2", "model_qualifier": "CFL 150", "winter_efficiency_pct": 79.0, "summer_efficiency_pct": 68.9, "comparative_hot_water_efficiency_pct": 50.3, "output_kw_max": 43.0, "final_year_of_manufacture": 2005, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009202", "000005", "0", "2012/Mar/27 10:12", "Baxi Potterton", "Potterton", "Osprey 2", "CFL 150", "GC No. 41-590-55", "2002", "2005", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "43", "43", "", "", "79.0", "68.9", "", "50.3", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.0", "80.2", "", "", "", "", "80.3"]} +{"pcdb_id": 9203, "brand_name": "Potterton", "model_name": "Osprey 2", "model_qualifier": "CFL 125", "winter_efficiency_pct": 79.5, "summer_efficiency_pct": 69.4, "comparative_hot_water_efficiency_pct": 50.7, "output_kw_max": 35.0, "final_year_of_manufacture": 2005, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009203", "000005", "0", "2012/Mar/27 10:12", "Baxi Potterton", "Potterton", "Osprey 2", "CFL 125", "GC No. 41-590-54", "2002", "2005", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "35", "35", "", "", "79.5", "69.4", "", "50.7", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.3", "81.0", "", "", "", "", "81.1"]} +{"pcdb_id": 9204, "brand_name": "Potterton", "model_name": "Kingfisher Mf", "model_qualifier": "CFL 40", "winter_efficiency_pct": 79.3, "summer_efficiency_pct": 69.2, "comparative_hot_water_efficiency_pct": 50.6, "output_kw_max": 11.72, "final_year_of_manufacture": 2006, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009204", "000005", "0", "2012/Mar/27 10:12", "Baxi Potterton", "Potterton", "Kingfisher Mf", "CFL 40", "GC No. 41-590-24", "2002", "2006", "1", "1", "1", "1", "0", "", "", "1", "1", "2", "11.72", "11.72", "", "", "79.3", "69.2", "", "50.6", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.3", "80.5", "", "", "", "", "80.7"]} +{"pcdb_id": 9205, "brand_name": "Potterton", "model_name": "Kingfisher Mf", "model_qualifier": "RSL 40", "winter_efficiency_pct": 79.4, "summer_efficiency_pct": 69.3, "comparative_hot_water_efficiency_pct": 50.7, "output_kw_max": 11.72, "final_year_of_manufacture": 2006, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009205", "000005", "0", "2012/Mar/27 10:12", "Baxi Potterton", "Potterton", "Kingfisher Mf", "RSL 40", "GC No. 41-590-35", "2002", "2006", "1", "1", "1", "1", "0", "", "", "1", "2", "2", "11.72", "11.72", "", "", "79.4", "69.3", "", "50.7", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.2", "80.9", "", "", "", "", "81.0"]} +{"pcdb_id": 9206, "brand_name": "Baxi Potterton", "model_name": "Potterton Promax", "model_qualifier": "System HE", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 30.18, "final_year_of_manufacture": 2005, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009206", "000005", "0", "2012/Mar/27 10:12", "Baxi Potterton", "Baxi Potterton", "Potterton Promax", "System HE", "GC No. 41-590-69", "2002", "2005", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "30.18", "30.18", "", "", "88.9", "79.9", "", "58.4", "", "2", "", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.4", "98.5", "", "", "", "", "96.8"]} +{"pcdb_id": 9207, "brand_name": "Fer Industrie", "model_name": "Falcon", "model_qualifier": "", "winter_efficiency_pct": 80.5, "summer_efficiency_pct": 70.4, "comparative_hot_water_efficiency_pct": 49.5, "output_kw_max": 23.8, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009207", "000220", "0", "2006/Jan/17 12:31", "Fer Industrie", "Fer Industrie", "Falcon", "", "", "1999", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "23.8", "23.8", "", "", "80.5", "70.4", "", "49.5", "", "2", "", "", "104", "1", "2", "150", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "", "", "0004", "", "", "", "", "", "", "", "", "83.1", "80.5", "", "", "", "", "81.0"]} +{"pcdb_id": 9208, "brand_name": "Fer Industrie", "model_name": "Falcon II", "model_qualifier": "", "winter_efficiency_pct": 78.9, "summer_efficiency_pct": 68.8, "comparative_hot_water_efficiency_pct": 48.4, "output_kw_max": 30.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009208", "000220", "0", "2006/Jan/17 12:31", "Fer Industrie", "Fer Industrie", "Falcon II", "", "", "1999", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "30", "30", "", "", "78.9", "68.8", "", "48.4", "", "2", "", "", "104", "1", "2", "150", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.5", "78.7", "", "", "", "", "79.2"]} +{"pcdb_id": 9209, "brand_name": "Ferroli", "model_name": "F30", "model_qualifier": "", "winter_efficiency_pct": 78.9, "summer_efficiency_pct": 68.8, "comparative_hot_water_efficiency_pct": 48.4, "output_kw_max": 30.0, "final_year_of_manufacture": 2006, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009209", "000097", "0", "2009/Apr/28 16:14", "Ferroli SpA", "Ferroli", "F30", "", "", "2001", "2006", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "30", "30", "", "", "78.9", "68.8", "", "48.4", "", "2", "", "", "104", "1", "2", "150", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.5", "78.7", "", "", "", "", "79.2"]} +{"pcdb_id": 9210, "brand_name": "Ferroli", "model_name": "F24", "model_qualifier": "", "winter_efficiency_pct": 80.5, "summer_efficiency_pct": 70.4, "comparative_hot_water_efficiency_pct": 49.5, "output_kw_max": 23.8, "final_year_of_manufacture": 2006, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009210", "000097", "0", "2009/Apr/28 16:14", "Ferroli SpA", "Ferroli", "F24", "", "", "2001", "2006", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "23.8", "23.8", "", "", "80.5", "70.4", "", "49.5", "", "2", "", "", "104", "1", "2", "150", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "83.1", "80.5", "", "", "", "", "81.0"]} +{"pcdb_id": 9211, "brand_name": "Alpha", "model_name": "CD24S", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 23.6, "final_year_of_manufacture": 2007, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009211", "000001", "0", "2012/Mar/27 10:12", "Alpha Therm", "Alpha", "CD24S", "", "", "2002", "2007", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "23.6", "23.6", "", "", "88.1", "79.1", "", "57.7", "", "2", "", "", "102", "1", "2", "125", "2", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.3", "96.4", "", "", "", "", "95.1"]} +{"pcdb_id": 9212, "brand_name": "Alpha", "model_name": "CD24C", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 55.9, "output_kw_max": 23.6, "final_year_of_manufacture": 2007, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009212", "000001", "0", "2011/Sep/06 13:10", "Alpha Therm", "Alpha", "CD24C", "", "", "2002", "2007", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "23.6", "23.6", "", "", "88.1", "79.5", "", "55.9", "", "2", "", "", "104", "1", "2", "130", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.3", "96.4", "", "", "", "", "95.1"]} +{"pcdb_id": 9213, "brand_name": "Alpha", "model_name": "CB50", "model_qualifier": "", "winter_efficiency_pct": 81.1, "summer_efficiency_pct": 72.0, "comparative_hot_water_efficiency_pct": 51.1, "output_kw_max": 28.0, "final_year_of_manufacture": 2005, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009213", "000001", "0", "2024/Jan/31 10:17", "Alpha Therm", "Alpha", "CB50", "", "", "2002", "2005", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "28.0", "28.0", "", "", "81.1", "72.0", "", "51.1", "", "2", "", "", "106", "1", "2", "165", "2", "2", "2", "0", "57", "0", "50", "5", "60", "0.97", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "83.1", "80.9", "", "", "", "", "81.3"]} +{"pcdb_id": 9214, "brand_name": "Biasi", "model_name": "Garda", "model_qualifier": "M90F. 24S", "winter_efficiency_pct": 79.1, "summer_efficiency_pct": 69.0, "comparative_hot_water_efficiency_pct": 48.5, "output_kw_max": 24.3, "final_year_of_manufacture": 2007, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009214", "000208", "0", "2008/May/22 11:39", "Biasi SpA", "Biasi", "Garda", "M90F. 24S", "47-970-19", "2002", "2007", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "24.3", "24.3", "", "", "79.1", "69.0", "", "48.5", "", "2", "", "", "104", "1", "2", "150", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.3", "78.4", "", "", "", "", "79.1"]} +{"pcdb_id": 9215, "brand_name": "Biasi", "model_name": "Garda", "model_qualifier": "M90F. 28S", "winter_efficiency_pct": 79.2, "summer_efficiency_pct": 69.1, "comparative_hot_water_efficiency_pct": 48.6, "output_kw_max": 28.4, "final_year_of_manufacture": 2007, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009215", "000208", "0", "2008/May/22 11:38", "Biasi SpA", "Biasi", "Garda", "M90F. 28S", "47-970-20", "2002", "2007", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "28.4", "28.4", "", "", "79.2", "69.1", "", "48.6", "", "2", "", "", "104", "1", "2", "170", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.2", "78.6", "", "", "", "", "79.3"]} +{"pcdb_id": 9216, "brand_name": "Biasi", "model_name": "Garda", "model_qualifier": "M90F. 24SR", "winter_efficiency_pct": 79.3, "summer_efficiency_pct": 68.6, "comparative_hot_water_efficiency_pct": 50.1, "output_kw_max": 24.3, "final_year_of_manufacture": 2007, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009216", "000208", "0", "2012/Mar/27 10:12", "Biasi SpA", "Biasi", "Garda", "M90F. 24SR", "41-970-10", "2002", "2007", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "24.3", "24.3", "", "", "79.3", "68.6", "", "50.1", "", "2", "", "", "102", "1", "2", "150", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.3", "78.4", "", "", "", "", "79.1"]} +{"pcdb_id": 9217, "brand_name": "Biasi", "model_name": "Garda", "model_qualifier": "M90F. 28SR", "winter_efficiency_pct": 79.4, "summer_efficiency_pct": 68.7, "comparative_hot_water_efficiency_pct": 50.2, "output_kw_max": 28.4, "final_year_of_manufacture": 2007, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009217", "000208", "0", "2012/Mar/27 10:12", "Biasi SpA", "Biasi", "Garda", "M90F. 28SR", "41-970-11", "2002", "2007", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "28.4", "28.4", "", "", "79.4", "68.7", "", "50.2", "", "2", "", "", "102", "1", "2", "170", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.2", "78.6", "", "", "", "", "79.3"]} +{"pcdb_id": 9218, "brand_name": "Biasi", "model_name": "Riva Plus", "model_qualifier": "M90D.28SR", "winter_efficiency_pct": 79.4, "summer_efficiency_pct": 68.7, "comparative_hot_water_efficiency_pct": 50.2, "output_kw_max": 28.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009218", "000208", "0", "2012/Mar/27 10:12", "Biasi SpA", "Biasi", "Riva Plus", "M90D.28SR", "41-970-09", "2002", "current", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "28.4", "28.4", "", "", "79.4", "68.7", "", "50.2", "", "2", "", "", "102", "1", "2", "170", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.2", "78.6", "", "", "", "", "79.3"]} +{"pcdb_id": 9219, "brand_name": "Biasi", "model_name": "Riva Plus", "model_qualifier": "M90D.28S", "winter_efficiency_pct": 79.2, "summer_efficiency_pct": 69.1, "comparative_hot_water_efficiency_pct": 48.6, "output_kw_max": 28.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009219", "000208", "0", "2006/Jan/17 12:31", "Biasi SpA", "Biasi", "Riva Plus", "M90D.28S", "47-970-16", "2002", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "28.4", "28.4", "", "", "79.2", "69.1", "", "48.6", "", "2", "", "", "104", "1", "2", "170", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.2", "78.6", "", "", "", "", "79.3"]} +{"pcdb_id": 9220, "brand_name": "Biasi", "model_name": "Riva Plus", "model_qualifier": "M90D.24S", "winter_efficiency_pct": 79.1, "summer_efficiency_pct": 69.0, "comparative_hot_water_efficiency_pct": 48.5, "output_kw_max": 24.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009220", "000208", "0", "2006/Jan/17 12:31", "Biasi SpA", "Biasi", "Riva Plus", "M90D.24S", "47-970-15", "2002", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "24.3", "24.3", "", "", "79.1", "69.0", "", "48.5", "", "2", "", "", "104", "1", "2", "150", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.3", "78.4", "", "", "", "", "79.1"]} +{"pcdb_id": 9221, "brand_name": "Biasi", "model_name": "Riva Plus", "model_qualifier": "M90D.24SR", "winter_efficiency_pct": 79.3, "summer_efficiency_pct": 68.6, "comparative_hot_water_efficiency_pct": 50.1, "output_kw_max": 24.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009221", "000208", "0", "2012/Mar/27 10:12", "Biasi SpA", "Biasi", "Riva Plus", "M90D.24SR", "41-970-08", "2002", "current", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "24.3", "24.3", "", "", "79.3", "68.6", "", "50.1", "", "2", "", "", "102", "1", "2", "150", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.3", "78.4", "", "", "", "", "79.1"]} +{"pcdb_id": 9222, "brand_name": "Biasi", "model_name": "Riva Compact", "model_qualifier": "M90E.24S", "winter_efficiency_pct": 79.1, "summer_efficiency_pct": 69.0, "comparative_hot_water_efficiency_pct": 48.5, "output_kw_max": 24.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009222", "000208", "0", "2006/Jan/17 12:31", "Biasi SpA", "Biasi", "Riva Compact", "M90E.24S", "47-970-17", "2002", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "24.3", "24.3", "", "", "79.1", "69.0", "", "48.5", "", "2", "", "", "104", "1", "2", "150", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.3", "78.4", "", "", "", "", "79.1"]} +{"pcdb_id": 9223, "brand_name": "Biasi", "model_name": "Riva Compact", "model_qualifier": "M90E.28S", "winter_efficiency_pct": 79.2, "summer_efficiency_pct": 69.1, "comparative_hot_water_efficiency_pct": 48.6, "output_kw_max": 28.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009223", "000208", "0", "2006/Jan/17 12:31", "Biasi SpA", "Biasi", "Riva Compact", "M90E.28S", "47-970-18", "2002", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "28.4", "28.4", "", "", "79.2", "69.1", "", "48.6", "", "2", "", "", "104", "1", "2", "150", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.2", "78.6", "", "", "", "", "79.3"]} +{"pcdb_id": 9224, "brand_name": "Potterton", "model_name": "FF75", "model_qualifier": "", "winter_efficiency_pct": 79.3, "summer_efficiency_pct": 69.2, "comparative_hot_water_efficiency_pct": 50.5, "output_kw_max": 23.45, "final_year_of_manufacture": 2005, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009224", "000005", "0", "2012/Mar/27 10:12", "Baxi Potterton", "Potterton", "FF75", "", "GC 41 590 72", "2002", "2005", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "23.45", "23.45", "", "", "79.3", "69.2", "", "50.5", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.5", "80.3", "", "", "", "", "80.5"]} +{"pcdb_id": 9225, "brand_name": "Potterton", "model_name": "FF55", "model_qualifier": "", "winter_efficiency_pct": 79.1, "summer_efficiency_pct": 69.0, "comparative_hot_water_efficiency_pct": 50.4, "output_kw_max": 17.58, "final_year_of_manufacture": 2005, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009225", "000005", "0", "2012/Mar/27 10:12", "Baxi Potterton", "Potterton", "FF55", "", "GC 41 590 71", "2002", "2005", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "17.58", "17.58", "", "", "79.1", "69.0", "", "50.4", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.0", "80.5", "", "", "", "", "80.6"]} +{"pcdb_id": 9226, "brand_name": "Worcester", "model_name": "Bosch/British Gas RD529", "model_qualifier": "ZWB 7-29 A", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 55.9, "output_kw_max": 29.2, "final_year_of_manufacture": 2003, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009226", "000035", "0", "2003/Jun/17 12:53", "Worcester Heat Systems", "Worcester", "Bosch/British Gas RD529", "ZWB 7-29 A", "47 108 09", "2002", "2003", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "29.2", "29.2", "", "", "88.1", "79.5", "", "55.9", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.9", "96.8", "", "", "", "", "95.3"]} +{"pcdb_id": 9227, "brand_name": "Worcester", "model_name": "26 CDi Xtra", "model_qualifier": "RSF - L", "winter_efficiency_pct": 85.8, "summer_efficiency_pct": 77.2, "comparative_hot_water_efficiency_pct": 54.3, "output_kw_max": 26.0, "final_year_of_manufacture": 2005, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009227", "000035", "0", "2020/Sep/04 08:04", "Worcester Heat Systems", "Worcester", "26 CDi Xtra", "RSF - L", "47 311 41", "1998", "2005", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "26", "26", "", "", "85.8", "77.2", "", "54.3", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "86.6", "91.7", "", "", "", "", "90.7"]} +{"pcdb_id": 9228, "brand_name": "Keston", "model_name": "K", "model_qualifier": "40", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 44.9, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009228", "000022", "0", "2012/Mar/27 10:12", "Keston Boilers", "Keston", "K", "40", "C40", "2002", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "44.9", "44.9", "", "", "88.6", "79.6", "", "58.1", "", "2", "", "", "102", "1", "2", "260", "8", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.5", "98.0", "", "", "", "", "96.2"]} +{"pcdb_id": 9229, "brand_name": "Keston", "model_name": "K", "model_qualifier": "55", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 55.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009229", "000022", "0", "2012/Mar/27 10:12", "Keston Boilers", "Keston", "K", "55", "C55", "2002", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "55.2", "55.2", "", "", "89.0", "80.0", "", "58.5", "", "2", "", "", "102", "1", "2", "260", "8", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "99.5", "", "", "", "", "97.3"]} +{"pcdb_id": 9231, "brand_name": "Merlin", "model_name": "2000", "model_qualifier": "80/100 BL", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 29.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009231", "000210", "0", "2012/Mar/27 10:12", "BH Associates", "Merlin", "2000", "80/100 BL", "", "1999", "current", "4", "1", "1", "1", "0", "", "", "1", "2", "1", "23.4", "29.3", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.5", "87.4", "", "", "", "", "87.4"]} +{"pcdb_id": 9232, "brand_name": "Merlin", "model_name": "2000", "model_qualifier": "80/100 CF", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 29.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009232", "000210", "0", "2012/Mar/27 10:12", "BH Associates", "Merlin", "2000", "80/100 CF", "", "1999", "current", "4", "1", "1", "1", "0", "", "", "1", "1", "1", "23.4", "29.3", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.5", "87.4", "", "", "", "", "87.4"]} +{"pcdb_id": 9233, "brand_name": "Merlin", "model_name": "2000", "model_qualifier": "60/80 CF", "winter_efficiency_pct": 86.6, "summer_efficiency_pct": 74.9, "comparative_hot_water_efficiency_pct": 54.7, "output_kw_max": 23.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009233", "000210", "0", "2012/Mar/27 10:12", "BH Associates", "Merlin", "2000", "60/80 CF", "", "1999", "current", "4", "1", "1", "1", "0", "", "", "1", "1", "1", "17.6", "23.4", "", "", "86.6", "74.9", "", "54.7", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.3", "87.0", "", "", "", "", "87.1"]} +{"pcdb_id": 9234, "brand_name": "Merlin", "model_name": "2000", "model_qualifier": "60/80 BL", "winter_efficiency_pct": 86.6, "summer_efficiency_pct": 74.9, "comparative_hot_water_efficiency_pct": 54.7, "output_kw_max": 23.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009234", "000210", "0", "2012/Mar/27 10:12", "BH Associates", "Merlin", "2000", "60/80 BL", "", "1999", "current", "4", "1", "1", "1", "0", "", "", "1", "2", "1", "17.6", "23.4", "", "", "86.6", "74.9", "", "54.7", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.3", "87.0", "", "", "", "", "87.1"]} +{"pcdb_id": 9235, "brand_name": "Merlin", "model_name": "2000", "model_qualifier": "40/60 CF", "winter_efficiency_pct": 86.4, "summer_efficiency_pct": 74.7, "comparative_hot_water_efficiency_pct": 54.6, "output_kw_max": 17.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009235", "000210", "0", "2012/Mar/27 10:12", "BH Associates", "Merlin", "2000", "40/60 CF", "", "1999", "current", "4", "1", "1", "1", "0", "", "", "1", "1", "1", "11.7", "17.6", "", "", "86.4", "74.7", "", "54.6", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.0", "86.7", "", "", "", "", "86.7"]} +{"pcdb_id": 9236, "brand_name": "Merlin", "model_name": "2000", "model_qualifier": "40/60 BL", "winter_efficiency_pct": 86.4, "summer_efficiency_pct": 74.7, "comparative_hot_water_efficiency_pct": 54.6, "output_kw_max": 17.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009236", "000210", "0", "2012/Mar/27 10:12", "BH Associates", "Merlin", "2000", "40/60 BL", "", "1999", "current", "4", "1", "1", "1", "0", "", "", "1", "2", "1", "11.7", "17.6", "", "", "86.4", "74.7", "", "54.6", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.0", "86.7", "", "", "", "", "86.7"]} +{"pcdb_id": 9237, "brand_name": "Heating World Group", "model_name": "Grandee 2S 18/22 BF EXT", "model_qualifier": "", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 22.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009237", "000050", "0", "2012/Mar/27 10:12", "Heating World Group", "Heating World Group", "Grandee 2S 18/22 BF EXT", "", "", "1993", "current", "4", "2", "2", "1", "0", "", "", "1", "2", "2", "18", "22", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.0", "87.7", "", "", "", "", "87.6"]} +{"pcdb_id": 9238, "brand_name": "Heating World Group", "model_name": "Grandee 2S 18/22 BF", "model_qualifier": "", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 22.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009238", "000050", "0", "2012/Mar/27 10:12", "Heating World Group", "Heating World Group", "Grandee 2S 18/22 BF", "", "", "1993", "current", "4", "2", "2", "1", "0", "", "", "1", "2", "2", "18", "22", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.0", "87.7", "", "", "", "", "87.6"]} +{"pcdb_id": 9239, "brand_name": "Heating World Group", "model_name": "Grandee 2S 18/22 CF", "model_qualifier": "", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 22.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009239", "000050", "0", "2012/Mar/27 10:12", "Heating World Group", "Heating World Group", "Grandee 2S 18/22 CF", "", "", "1993", "current", "4", "2", "2", "1", "0", "", "", "1", "1", "2", "18", "22", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.0", "87.7", "", "", "", "", "87.6"]} +{"pcdb_id": 9240, "brand_name": "Heating World Group", "model_name": "Grandee 3S 22/27 BF", "model_qualifier": "", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 27.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009240", "000050", "0", "2012/Mar/27 10:12", "Heating World Group", "Heating World Group", "Grandee 3S 22/27 BF", "", "", "1993", "current", "4", "2", "2", "1", "0", "", "", "1", "2", "2", "22", "27", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.4", "87.2", "", "", "", "", "87.1"]} +{"pcdb_id": 9241, "brand_name": "Heating World Group", "model_name": "Grandee 3S 22/27 CF", "model_qualifier": "", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 27.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009241", "000050", "0", "2012/Mar/27 10:12", "Heating World Group", "Heating World Group", "Grandee 3S 22/27 CF", "", "", "1993", "current", "4", "2", "2", "1", "0", "", "", "1", "1", "2", "22", "27", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.4", "87.2", "", "", "", "", "87.1"]} +{"pcdb_id": 9242, "brand_name": "Heating World Group", "model_name": "Grandee 3S 22/27 BF EXT", "model_qualifier": "", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 27.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009242", "000050", "0", "2012/Mar/27 10:12", "Heating World Group", "Heating World Group", "Grandee 3S 22/27 BF EXT", "", "", "1993", "current", "4", "2", "2", "1", "0", "", "", "1", "2", "2", "22", "27", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.4", "87.2", "", "", "", "", "87.1"]} +{"pcdb_id": 9243, "brand_name": "Heating World Group", "model_name": "Grandee 5S 12/18 CF", "model_qualifier": "", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 18.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009243", "000050", "0", "2012/Mar/27 10:12", "Heating World Group", "Heating World Group", "Grandee 5S 12/18 CF", "", "", "1993", "current", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "12", "18", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.4", "88.2", "", "", "", "", "88.0"]} +{"pcdb_id": 9244, "brand_name": "Heating World Group", "model_name": "Grandee 5S 12/18 BF", "model_qualifier": "", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 18.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009244", "000050", "0", "2012/Mar/27 10:12", "Heating World Group", "Heating World Group", "Grandee 5S 12/18 BF", "", "", "1993", "current", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "12", "18", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.4", "88.2", "", "", "", "", "88.0"]} +{"pcdb_id": 9245, "brand_name": "Heating World Group", "model_name": "Grandee 1S 12/18 CF", "model_qualifier": "", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 18.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009245", "000050", "0", "2012/Mar/27 10:12", "Heating World Group", "Heating World Group", "Grandee 1S 12/18 CF", "", "", "1993", "current", "4", "2", "2", "1", "0", "", "", "1", "1", "2", "12", "18", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.4", "88.2", "", "", "", "", "88.0"]} +{"pcdb_id": 9246, "brand_name": "Heating World Group", "model_name": "Grandee 1S 12/18 BF EXT", "model_qualifier": "", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 18.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009246", "000050", "0", "2012/Mar/27 10:12", "Heating World Group", "Heating World Group", "Grandee 1S 12/18 BF EXT", "", "", "1993", "current", "4", "2", "2", "1", "0", "", "", "1", "2", "2", "12", "18", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.4", "88.2", "", "", "", "", "88.0"]} +{"pcdb_id": 9247, "brand_name": "Heating World Group", "model_name": "Sorrento SHI 12/18 BF", "model_qualifier": "", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 18.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009247", "000050", "0", "2012/Mar/27 10:12", "Heating World Group", "Heating World Group", "Sorrento SHI 12/18 BF", "", "", "1993", "current", "4", "4", "1", "1", "0", "", "", "1", "2", "2", "12", "18", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.4", "88.2", "", "", "", "", "88.0"]} +{"pcdb_id": 9248, "brand_name": "Heating World Group", "model_name": "Sorrento SHI 12/18 CF", "model_qualifier": "", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 18.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009248", "000050", "0", "2012/Mar/27 10:12", "Heating World Group", "Heating World Group", "Sorrento SHI 12/18 CF", "", "", "1993", "current", "4", "4", "1", "1", "0", "", "", "1", "1", "2", "12", "18", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.4", "88.2", "", "", "", "", "88.0"]} +{"pcdb_id": 9249, "brand_name": "Heating World Group", "model_name": "Sorrento SFS 12/18 CF", "model_qualifier": "", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 18.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009249", "000050", "0", "2012/Mar/27 10:12", "Heating World Group", "Heating World Group", "Sorrento SFS 12/18 CF", "", "", "1993", "current", "4", "4", "1", "1", "0", "", "", "1", "1", "2", "12", "18", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.4", "88.2", "", "", "", "", "88.0"]} +{"pcdb_id": 9250, "brand_name": "Heating World Group", "model_name": "Sorrento SFS 12/18 BF", "model_qualifier": "", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 18.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009250", "000050", "0", "2012/Mar/27 10:12", "Heating World Group", "Heating World Group", "Sorrento SFS 12/18 BF", "", "", "1993", "current", "4", "4", "1", "1", "0", "", "", "1", "2", "2", "12", "18", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.4", "88.2", "", "", "", "", "88.0"]} +{"pcdb_id": 9251, "brand_name": "Heating World Group", "model_name": "Flamevector SHI 12/18 BF", "model_qualifier": "", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 18.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009251", "000050", "0", "2012/Mar/27 10:12", "Heating World Group", "Heating World Group", "Flamevector SHI 12/18 BF", "", "", "1993", "current", "4", "4", "1", "1", "0", "", "", "1", "2", "2", "12", "18", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.4", "88.2", "", "", "", "", "88.0"]} +{"pcdb_id": 9252, "brand_name": "Heating World Group", "model_name": "Flamevector SHI 12/18 CF", "model_qualifier": "", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 18.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009252", "000050", "0", "2012/Mar/27 10:12", "Heating World Group", "Heating World Group", "Flamevector SHI 12/18 CF", "", "", "1993", "current", "4", "4", "1", "1", "0", "", "", "1", "1", "2", "12", "18", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.4", "88.2", "", "", "", "", "88.0"]} +{"pcdb_id": 9253, "brand_name": "Heating World Group", "model_name": "Flamevector SHFS 12/18 BF", "model_qualifier": "", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 18.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009253", "000050", "0", "2012/Mar/27 10:12", "Heating World Group", "Heating World Group", "Flamevector SHFS 12/18 BF", "", "", "1993", "current", "4", "4", "1", "1", "0", "", "", "1", "2", "2", "12", "18", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.4", "88.2", "", "", "", "", "88.0"]} +{"pcdb_id": 9254, "brand_name": "Heating World Group", "model_name": "Flamevector SHFS 12/18 CF", "model_qualifier": "", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 18.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009254", "000050", "0", "2012/Mar/27 10:12", "Heating World Group", "Heating World Group", "Flamevector SHFS 12/18 CF", "", "", "1993", "current", "4", "4", "1", "1", "0", "", "", "1", "1", "2", "12", "18", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.4", "88.2", "", "", "", "", "88.0"]} +{"pcdb_id": 9255, "brand_name": "Heating World Group", "model_name": "Grandee Combi SW 15/20 BF", "model_qualifier": "", "winter_efficiency_pct": 83.8, "summer_efficiency_pct": 74.3, "comparative_hot_water_efficiency_pct": 52.2, "output_kw_max": 20.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009255", "000050", "0", "2002/Jul/30 10:47", "Heating World Group", "Heating World Group", "Grandee Combi SW 15/20 BF", "", "", "1998", "current", "4", "2", "2", "2", "0", "", "", "1", "2", "2", "15", "20", "", "", "83.8", "74.3", "", "52.2", "", "2", "", "", "202", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.7", "85.0", "", "", "", "", "85.3"]} +{"pcdb_id": 9256, "brand_name": "Heating World Group", "model_name": "Grandee Combi SW 15/20 CF", "model_qualifier": "", "winter_efficiency_pct": 83.8, "summer_efficiency_pct": 74.3, "comparative_hot_water_efficiency_pct": 52.2, "output_kw_max": 20.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009256", "000050", "0", "2002/Jul/30 10:47", "Heating World Group", "Heating World Group", "Grandee Combi SW 15/20 CF", "", "", "1998", "current", "4", "2", "2", "2", "0", "", "", "1", "1", "2", "15", "20", "", "", "83.8", "74.3", "", "52.2", "", "2", "", "", "202", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.7", "85.0", "", "", "", "", "85.3"]} +{"pcdb_id": 9257, "brand_name": "Heating World Group", "model_name": "Grandee Combi SW 20/24 BF", "model_qualifier": "", "winter_efficiency_pct": 84.4, "summer_efficiency_pct": 74.9, "comparative_hot_water_efficiency_pct": 52.6, "output_kw_max": 24.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009257", "000050", "0", "2002/Jul/30 10:47", "Heating World Group", "Heating World Group", "Grandee Combi SW 20/24 BF", "", "", "1998", "current", "4", "2", "2", "2", "0", "", "", "1", "2", "2", "20", "24", "", "", "84.4", "74.9", "", "52.6", "", "2", "", "", "202", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.6", "86.1", "", "", "", "", "86.2"]} +{"pcdb_id": 9258, "brand_name": "Heating World Group", "model_name": "Grandee Combi SW 20/24 CF", "model_qualifier": "", "winter_efficiency_pct": 84.4, "summer_efficiency_pct": 74.9, "comparative_hot_water_efficiency_pct": 52.6, "output_kw_max": 20.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009258", "000050", "0", "2002/Jul/30 10:48", "Heating World Group", "Heating World Group", "Grandee Combi SW 20/24 CF", "", "", "1998", "current", "4", "2", "2", "2", "0", "", "", "1", "1", "2", "15", "20", "", "", "84.4", "74.9", "", "52.6", "", "2", "", "", "202", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.6", "86.1", "", "", "", "", "86.2"]} +{"pcdb_id": 9259, "brand_name": "Heating World Group", "model_name": "Grandee Combi SW 24/27 BF", "model_qualifier": "", "winter_efficiency_pct": 84.9, "summer_efficiency_pct": 75.4, "comparative_hot_water_efficiency_pct": 53.0, "output_kw_max": 27.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009259", "000050", "0", "2002/Jul/30 10:49", "Heating World Group", "Heating World Group", "Grandee Combi SW 24/27 BF", "", "", "1998", "current", "4", "2", "2", "2", "0", "", "", "1", "2", "2", "24", "27", "", "", "84.9", "75.4", "", "53.0", "", "2", "", "", "202", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.4", "87.2", "", "", "", "", "87.1"]} +{"pcdb_id": 9260, "brand_name": "Heating World Group", "model_name": "Grandee Combi SW 24/27 CF", "model_qualifier": "", "winter_efficiency_pct": 84.9, "summer_efficiency_pct": 75.4, "comparative_hot_water_efficiency_pct": 53.0, "output_kw_max": 27.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009260", "000050", "0", "2002/Jul/30 10:49", "Heating World Group", "Heating World Group", "Grandee Combi SW 24/27 CF", "", "", "1998", "current", "4", "2", "2", "2", "0", "", "", "1", "1", "2", "24", "27", "", "", "84.9", "75.4", "", "53.0", "", "2", "", "", "202", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.4", "87.2", "", "", "", "", "87.1"]} +{"pcdb_id": 9261, "brand_name": "Heating World Group", "model_name": "Grandee Combi SFS 25/29 BF", "model_qualifier": "", "winter_efficiency_pct": 84.5, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 52.8, "output_kw_max": 29.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009261", "000050", "0", "2002/Jul/30 10:50", "Heating World Group", "Heating World Group", "Grandee Combi SFS 25/29 BF", "", "", "1998", "current", "4", "1", "1", "2", "0", "", "", "1", "2", "2", "25", "29", "", "", "84.5", "75.0", "", "52.8", "", "2", "", "", "202", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.1", "86.6", "", "", "", "", "86.5"]} +{"pcdb_id": 9262, "brand_name": "Heating World Group", "model_name": "Grandee Combi SFS 25/29 CF", "model_qualifier": "", "winter_efficiency_pct": 84.5, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 52.8, "output_kw_max": 29.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009262", "000050", "0", "2002/Jul/30 10:24", "Heating World Group", "Heating World Group", "Grandee Combi SFS 25/29 CF", "", "", "1998", "current", "4", "1", "1", "2", "0", "", "", "1", "1", "2", "25", "29", "", "", "84.5", "75.0", "", "52.8", "", "2", "", "", "202", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.1", "86.6", "", "", "", "", "86.5"]} +{"pcdb_id": 9263, "brand_name": "Heating World Group", "model_name": "Grandee Combi SFS 20/25 BF", "model_qualifier": "", "winter_efficiency_pct": 84.2, "summer_efficiency_pct": 74.7, "comparative_hot_water_efficiency_pct": 52.5, "output_kw_max": 25.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009263", "000050", "0", "2002/Jul/30 10:25", "Heating World Group", "Heating World Group", "Grandee Combi SFS 20/25 BF", "", "", "1998", "current", "4", "1", "1", "2", "0", "", "", "1", "2", "2", "20", "25", "", "", "84.2", "74.7", "", "52.5", "", "2", "", "", "202", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.4", "85.8", "", "", "", "", "85.9"]} +{"pcdb_id": 9264, "brand_name": "Heating World Group", "model_name": "Grandee Combi SFS 20/25 CF", "model_qualifier": "", "winter_efficiency_pct": 84.2, "summer_efficiency_pct": 74.7, "comparative_hot_water_efficiency_pct": 52.5, "output_kw_max": 25.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009264", "000050", "0", "2002/Jul/30 10:25", "Heating World Group", "Heating World Group", "Grandee Combi SFS 20/25 CF", "", "", "1998", "current", "4", "1", "1", "2", "0", "", "", "1", "1", "2", "20", "25", "", "", "84.2", "74.7", "", "52.5", "", "2", "", "", "202", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.4", "85.8", "", "", "", "", "85.9"]} +{"pcdb_id": 9265, "brand_name": "Heating World Group", "model_name": "Grandee Combi SFS 15/20 CF", "model_qualifier": "", "winter_efficiency_pct": 83.6, "summer_efficiency_pct": 74.1, "comparative_hot_water_efficiency_pct": 52.1, "output_kw_max": 20.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009265", "000050", "0", "2002/Jul/30 10:26", "Heating World Group", "Heating World Group", "Grandee Combi SFS 15/20 CF", "", "", "1998", "current", "4", "1", "1", "2", "0", "", "", "1", "1", "2", "15", "20", "", "", "83.6", "74.1", "", "52.1", "", "2", "", "", "202", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.2", "84.5", "", "", "", "", "85.0"]} +{"pcdb_id": 9266, "brand_name": "Heating World Group", "model_name": "Grandee Combi SFS 15/20 BF", "model_qualifier": "", "winter_efficiency_pct": 83.6, "summer_efficiency_pct": 74.1, "comparative_hot_water_efficiency_pct": 52.1, "output_kw_max": 20.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009266", "000050", "0", "2002/Jul/30 10:26", "Heating World Group", "Heating World Group", "Grandee Combi SFS 15/20 BF", "", "", "1998", "current", "4", "1", "1", "2", "0", "", "", "1", "2", "2", "15", "20", "", "", "83.6", "74.1", "", "52.1", "", "2", "", "", "202", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.2", "84.5", "", "", "", "", "85.0"]} +{"pcdb_id": 9267, "brand_name": "Heating World Group", "model_name": "Grandee 1S 12/18 BF", "model_qualifier": "", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 18.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009267", "000050", "0", "2012/Mar/27 10:12", "Heating World Group", "Heating World Group", "Grandee 1S 12/18 BF", "", "", "1993", "current", "4", "2", "2", "1", "0", "", "", "1", "2", "2", "12", "18", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.4", "88.2", "", "", "", "", "88.0"]} +{"pcdb_id": 9268, "brand_name": "Heating World Group", "model_name": "Grandee Combi Compact", "model_qualifier": "SFS 15/20 BF", "winter_efficiency_pct": 83.6, "summer_efficiency_pct": 74.1, "comparative_hot_water_efficiency_pct": 52.1, "output_kw_max": 20.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009268", "000050", "0", "2002/Jul/30 10:26", "Heating World Group", "Heating World Group", "Grandee Combi Compact", "SFS 15/20 BF", "", "1997", "current", "4", "1", "1", "2", "0", "", "", "1", "2", "1", "15", "20", "", "", "83.6", "74.1", "", "52.1", "", "2", "", "", "202", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "0", "", "0002", "", "", "", "", "", "", "", "", "87.2", "84.5", "", "", "", "", "85.0"]} +{"pcdb_id": 9269, "brand_name": "Heating World Group", "model_name": "Grandee Combi Compact", "model_qualifier": "SFS 15-20 CF", "winter_efficiency_pct": 83.6, "summer_efficiency_pct": 74.1, "comparative_hot_water_efficiency_pct": 52.1, "output_kw_max": 20.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009269", "000050", "0", "2002/Jul/30 10:27", "Heating World Group", "Heating World Group", "Grandee Combi Compact", "SFS 15-20 CF", "", "1997", "current", "4", "1", "1", "2", "0", "", "", "1", "1", "1", "15", "20", "", "", "83.6", "74.1", "", "52.1", "", "2", "", "", "202", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "0", "", "0002", "", "", "", "", "", "", "", "", "87.2", "84.5", "", "", "", "", "85.0"]} +{"pcdb_id": 9270, "brand_name": "Heating World Group", "model_name": "Grandee", "model_qualifier": "9S 40/50 CF", "winter_efficiency_pct": 85.6, "summer_efficiency_pct": 73.9, "comparative_hot_water_efficiency_pct": 54.0, "output_kw_max": 44.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009270", "000050", "0", "2012/Mar/27 10:12", "Heating World Group", "Heating World Group", "Grandee", "9S 40/50 CF", "", "1997", "current", "4", "1", "1", "1", "0", "", "", "1", "1", "1", "44", "44", "", "", "85.6", "73.9", "", "54.0", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.7", "85.0", "", "", "", "", "85.3"]} +{"pcdb_id": 9271, "brand_name": "Heating World Group", "model_name": "Grandee", "model_qualifier": "9S 40/50 BF", "winter_efficiency_pct": 85.6, "summer_efficiency_pct": 73.9, "comparative_hot_water_efficiency_pct": 54.0, "output_kw_max": 44.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009271", "000050", "0", "2012/Mar/27 10:12", "Heating World Group", "Heating World Group", "Grandee", "9S 40/50 BF", "", "1997", "current", "4", "1", "1", "1", "0", "", "", "1", "2", "1", "44", "44", "", "", "85.6", "73.9", "", "54.0", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.7", "85.0", "", "", "", "", "85.3"]} +{"pcdb_id": 9272, "brand_name": "Heating World Group", "model_name": "Grandee", "model_qualifier": "8S 35/40 BF", "winter_efficiency_pct": 85.6, "summer_efficiency_pct": 73.9, "comparative_hot_water_efficiency_pct": 54.0, "output_kw_max": 40.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009272", "000050", "0", "2012/Mar/27 10:12", "Heating World Group", "Heating World Group", "Grandee", "8S 35/40 BF", "", "1997", "current", "4", "1", "1", "1", "0", "", "", "1", "2", "1", "40", "40", "", "", "85.6", "73.9", "", "54.0", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.7", "85.0", "", "", "", "", "85.3"]} +{"pcdb_id": 9273, "brand_name": "Heating World Group", "model_name": "Grandee", "model_qualifier": "8S 35/40 CF", "winter_efficiency_pct": 85.6, "summer_efficiency_pct": 73.9, "comparative_hot_water_efficiency_pct": 54.0, "output_kw_max": 40.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009273", "000050", "0", "2012/Mar/27 10:12", "Heating World Group", "Heating World Group", "Grandee", "8S 35/40 CF", "", "1997", "current", "4", "1", "1", "1", "0", "", "", "1", "1", "1", "40", "40", "", "", "85.6", "73.9", "", "54.0", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.7", "85.0", "", "", "", "", "85.3"]} +{"pcdb_id": 9274, "brand_name": "Heating World Group", "model_name": "Grandee", "model_qualifier": "6S 15/23 BF", "winter_efficiency_pct": 85.6, "summer_efficiency_pct": 73.9, "comparative_hot_water_efficiency_pct": 54.0, "output_kw_max": 23.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009274", "000050", "0", "2012/Mar/27 10:12", "Heating World Group", "Heating World Group", "Grandee", "6S 15/23 BF", "", "1997", "current", "4", "1", "1", "1", "0", "", "", "1", "2", "1", "23", "23", "", "", "85.6", "73.9", "", "54.0", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.7", "85.0", "", "", "", "", "85.3"]} +{"pcdb_id": 9275, "brand_name": "Heating World Group", "model_name": "Grandee", "model_qualifier": "6S 15/23 CF", "winter_efficiency_pct": 85.6, "summer_efficiency_pct": 73.9, "comparative_hot_water_efficiency_pct": 54.0, "output_kw_max": 23.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009275", "000050", "0", "2012/Mar/27 10:12", "Heating World Group", "Heating World Group", "Grandee", "6S 15/23 CF", "", "1997", "current", "4", "1", "1", "1", "0", "", "", "1", "1", "1", "23", "23", "", "", "85.6", "73.9", "", "54.0", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.7", "85.0", "", "", "", "", "85.3"]} +{"pcdb_id": 9276, "brand_name": "Heating World Group", "model_name": "Grandee", "model_qualifier": "7S 26/32 BF", "winter_efficiency_pct": 85.6, "summer_efficiency_pct": 73.9, "comparative_hot_water_efficiency_pct": 54.0, "output_kw_max": 29.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009276", "000050", "0", "2012/Mar/27 10:12", "Heating World Group", "Heating World Group", "Grandee", "7S 26/32 BF", "", "1997", "current", "4", "1", "1", "1", "0", "", "", "1", "2", "1", "29", "29", "", "", "85.6", "73.9", "", "54.0", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.7", "85.0", "", "", "", "", "85.3"]} +{"pcdb_id": 9277, "brand_name": "Heating World Group", "model_name": "Grandee", "model_qualifier": "7S 26/32 CF", "winter_efficiency_pct": 85.6, "summer_efficiency_pct": 73.9, "comparative_hot_water_efficiency_pct": 54.0, "output_kw_max": 29.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009277", "000050", "0", "2012/Mar/27 10:12", "Heating World Group", "Heating World Group", "Grandee", "7S 26/32 CF", "", "1997", "current", "4", "1", "1", "1", "0", "", "", "1", "1", "1", "29", "29", "", "", "85.6", "73.9", "", "54.0", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.7", "85.0", "", "", "", "", "85.3"]} +{"pcdb_id": 9278, "brand_name": "Heating World Group", "model_name": "Flamevector", "model_qualifier": "SHFS 18/21 BF", "winter_efficiency_pct": 83.6, "summer_efficiency_pct": 71.9, "comparative_hot_water_efficiency_pct": 52.5, "output_kw_max": 18.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009278", "000050", "0", "2012/Mar/27 10:12", "Heating World Group", "Heating World Group", "Flamevector", "SHFS 18/21 BF", "", "1997", "current", "4", "1", "1", "1", "0", "", "", "1", "1", "1", "18", "18", "", "", "83.6", "71.9", "", "52.5", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.3", "84.9", "", "", "", "", "84.4"]} +{"pcdb_id": 9279, "brand_name": "Heating World Group", "model_name": "Flamevector", "model_qualifier": "SHFS 18/21 CF", "winter_efficiency_pct": 83.6, "summer_efficiency_pct": 71.9, "comparative_hot_water_efficiency_pct": 52.5, "output_kw_max": 18.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009279", "000050", "0", "2012/Mar/27 10:12", "Heating World Group", "Heating World Group", "Flamevector", "SHFS 18/21 CF", "", "1997", "current", "4", "1", "1", "1", "0", "", "", "1", "1", "1", "18", "18", "", "", "83.6", "71.9", "", "52.5", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.3", "84.9", "", "", "", "", "84.4"]} +{"pcdb_id": 9280, "brand_name": "Heating World Group", "model_name": "Flamevector", "model_qualifier": "SHI 18/21 BF", "winter_efficiency_pct": 83.6, "summer_efficiency_pct": 71.9, "comparative_hot_water_efficiency_pct": 52.5, "output_kw_max": 18.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009280", "000050", "0", "2012/Mar/27 10:12", "Heating World Group", "Heating World Group", "Flamevector", "SHI 18/21 BF", "", "1997", "current", "4", "1", "1", "1", "0", "", "", "1", "1", "1", "18", "18", "", "", "83.6", "71.9", "", "52.5", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.3", "84.9", "", "", "", "", "84.4"]} +{"pcdb_id": 9281, "brand_name": "Heating World Group", "model_name": "Flamevector", "model_qualifier": "SHI 18/21 CF", "winter_efficiency_pct": 83.6, "summer_efficiency_pct": 71.9, "comparative_hot_water_efficiency_pct": 52.5, "output_kw_max": 18.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009281", "000050", "0", "2012/Mar/27 10:12", "Heating World Group", "Heating World Group", "Flamevector", "SHI 18/21 CF", "", "1997", "current", "4", "1", "1", "1", "0", "", "", "1", "1", "1", "18", "18", "", "", "83.6", "71.9", "", "52.5", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.3", "84.9", "", "", "", "", "84.4"]} +{"pcdb_id": 9282, "brand_name": "Heating World Group", "model_name": "Sorrento", "model_qualifier": "SFS 18/21 CF", "winter_efficiency_pct": 83.6, "summer_efficiency_pct": 71.9, "comparative_hot_water_efficiency_pct": 52.5, "output_kw_max": 18.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009282", "000050", "0", "2012/Mar/27 10:12", "Heating World Group", "Heating World Group", "Sorrento", "SFS 18/21 CF", "", "1997", "current", "4", "1", "1", "1", "0", "", "", "1", "1", "1", "18", "18", "", "", "83.6", "71.9", "", "52.5", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.3", "84.9", "", "", "", "", "84.4"]} +{"pcdb_id": 9283, "brand_name": "Heating World Group", "model_name": "Sorrento", "model_qualifier": "SFS 18/21 BF", "winter_efficiency_pct": 83.6, "summer_efficiency_pct": 71.9, "comparative_hot_water_efficiency_pct": 52.5, "output_kw_max": 18.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009283", "000050", "0", "2012/Mar/27 10:12", "Heating World Group", "Heating World Group", "Sorrento", "SFS 18/21 BF", "", "1997", "current", "4", "1", "1", "1", "0", "", "", "1", "1", "1", "18", "18", "", "", "83.6", "71.9", "", "52.5", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.3", "84.9", "", "", "", "", "84.4"]} +{"pcdb_id": 9284, "brand_name": "Heating World Group", "model_name": "Sorrento", "model_qualifier": "SHI 18/21 BF", "winter_efficiency_pct": 83.6, "summer_efficiency_pct": 71.9, "comparative_hot_water_efficiency_pct": 52.5, "output_kw_max": 18.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009284", "000050", "0", "2012/Mar/27 10:12", "Heating World Group", "Heating World Group", "Sorrento", "SHI 18/21 BF", "", "1997", "current", "4", "1", "1", "1", "0", "", "", "1", "1", "1", "18", "18", "", "", "83.6", "71.9", "", "52.5", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.3", "84.9", "", "", "", "", "84.4"]} +{"pcdb_id": 9285, "brand_name": "Heating World Group", "model_name": "Sorrento", "model_qualifier": "SHI 18/21 CF", "winter_efficiency_pct": 83.6, "summer_efficiency_pct": 71.9, "comparative_hot_water_efficiency_pct": 52.5, "output_kw_max": 18.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009285", "000050", "0", "2012/Mar/27 10:12", "Heating World Group", "Heating World Group", "Sorrento", "SHI 18/21 CF", "", "1997", "current", "4", "1", "1", "1", "0", "", "", "1", "1", "1", "18", "18", "", "", "83.6", "71.9", "", "52.5", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.3", "84.9", "", "", "", "", "84.4"]} +{"pcdb_id": 9287, "brand_name": "Sile SpA", "model_name": "Turbinox 30", "model_qualifier": "", "winter_efficiency_pct": 80.1, "summer_efficiency_pct": 71.0, "comparative_hot_water_efficiency_pct": 31.2, "output_kw_max": 32.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009287", "000221", "0", "2024/Jan/31 10:17", "Sile SpA", "Sile SpA", "Turbinox 30", "", "", "1985", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "32.00", "32.00", "", "", "80.1", "71.0", "", "31.2", "", "2", "", "", "106", "1", "2", "179", "0", "2", "", "0", "65", "0", "10", "", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "0", "", "0004", "", "", "", "", "", "", "", "", "82.8", "79.3", "", "", "", "", "80.0"]} +{"pcdb_id": 9288, "brand_name": "Sile SpA", "model_name": "SuperRapida 22", "model_qualifier": "", "winter_efficiency_pct": 80.6, "summer_efficiency_pct": 70.5, "comparative_hot_water_efficiency_pct": 49.6, "output_kw_max": 24.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009288", "000221", "0", "2006/Jan/17 12:31", "Sile SpA", "Sile SpA", "SuperRapida 22", "", "", "", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "24", "24", "", "", "80.6", "70.5", "", "49.6", "", "2", "", "", "104", "1", "2", "0", "132", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "", "", "0004", "", "", "", "", "", "", "", "", "82.9", "80.6", "", "", "", "", "81.1"]} +{"pcdb_id": 9289, "brand_name": "Sile SpA", "model_name": "SuperRapida 26", "model_qualifier": "", "winter_efficiency_pct": 80.7, "summer_efficiency_pct": 70.6, "comparative_hot_water_efficiency_pct": 49.7, "output_kw_max": 28.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009289", "000221", "0", "2006/Jan/17 12:31", "Sile SpA", "Sile SpA", "SuperRapida 26", "", "", "", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "28", "28", "", "", "80.7", "70.6", "", "49.7", "", "2", "", "", "104", "1", "2", "0", "132", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "", "", "0004", "", "", "", "", "", "", "", "", "83.3", "81.0", "", "", "", "", "81.4"]} +{"pcdb_id": 9290, "brand_name": "Sile SpA", "model_name": "SuperRapida 31", "model_qualifier": "", "winter_efficiency_pct": 80.5, "summer_efficiency_pct": 70.4, "comparative_hot_water_efficiency_pct": 49.5, "output_kw_max": 34.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009290", "000221", "0", "2006/Jan/17 12:31", "Sile SpA", "Sile SpA", "SuperRapida 31", "", "", "", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "34", "34", "", "", "80.5", "70.4", "", "49.5", "", "2", "", "", "104", "1", "2", "174", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "", "", "0004", "", "", "", "", "", "", "", "", "83.9", "80.5", "", "", "", "", "81.2"]} +{"pcdb_id": 9291, "brand_name": "Sile SpA", "model_name": "Turbinox 30", "model_qualifier": "", "winter_efficiency_pct": 81.9, "summer_efficiency_pct": 72.8, "comparative_hot_water_efficiency_pct": 32.0, "output_kw_max": 32.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009291", "000221", "0", "2024/Jan/31 10:17", "Sile SpA", "Sile SpA", "Turbinox 30", "", "", "1985", "current", "2", "2", "1", "2", "0", "", "", "1", "2", "2", "32.0", "32.0", "", "", "81.9", "72.8", "", "32.0", "", "2", "1", "", "106", "1", "2", "179", "0", "2", "", "0", "65", "0", "10", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "84.6", "81.0", "", "", "", "", "81.7"]} +{"pcdb_id": 9293, "brand_name": "Sile SpA", "model_name": "SuperRapida 26", "model_qualifier": "", "winter_efficiency_pct": 82.6, "summer_efficiency_pct": 72.5, "comparative_hot_water_efficiency_pct": 51.0, "output_kw_max": 28.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009293", "000221", "0", "2006/Jan/17 12:31", "Sile SpA", "Sile SpA", "SuperRapida 26", "", "", "", "current", "2", "2", "1", "2", "0", "", "", "1", "2", "2", "28", "28", "", "", "82.6", "72.5", "", "51.0", "", "2", "1", "", "104", "1", "2", "132", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "", "", "0004", "", "", "", "", "", "", "", "", "85.1", "82.8", "", "", "", "", "83.2"]} +{"pcdb_id": 9294, "brand_name": "Sile SpA", "model_name": "SuperRapida 31", "model_qualifier": "", "winter_efficiency_pct": 82.3, "summer_efficiency_pct": 72.2, "comparative_hot_water_efficiency_pct": 50.8, "output_kw_max": 34.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009294", "000221", "0", "2006/Jan/17 12:31", "Sile SpA", "Sile SpA", "SuperRapida 31", "", "", "", "current", "2", "2", "1", "2", "0", "", "", "1", "2", "2", "34", "34", "", "", "82.3", "72.2", "", "50.8", "", "2", "1", "", "104", "1", "2", "174", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "", "", "0004", "", "", "", "", "", "", "", "", "85.7", "82.3", "", "", "", "", "83.0"]} +{"pcdb_id": 9295, "brand_name": "Ideal", "model_name": "Imax", "model_qualifier": "W60", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 60.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009295", "000008", "0", "2012/Mar/27 10:12", "Ideal Boilers", "Ideal", "Imax", "W60", "PI No 0063BN3218", "2002", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "60", "60", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "84", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.4", "97.7", "", "", "", "", "95.9"]} +{"pcdb_id": 9297, "brand_name": "Ideal", "model_name": "Imax", "model_qualifier": "W45P", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 45.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009297", "000008", "0", "2012/Mar/27 10:12", "Ideal Boilers", "Ideal", "Imax", "W45P", "PI No 0063BN3218", "2002", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "45", "45", "", "", "89.1", "80.1", "", "58.5", "", "2", "1", "", "102", "1", "2", "51", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.3", "99.4", "", "", "", "", "97.5"]} +{"pcdb_id": 9298, "brand_name": "Ideal", "model_name": "Imax", "model_qualifier": "W60P", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 80.4, "comparative_hot_water_efficiency_pct": 58.7, "output_kw_max": 60.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009298", "000008", "0", "2012/Mar/27 10:12", "Ideal Boilers", "Ideal", "Imax", "W60P", "PI No 0063BN3218", "2002", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "60", "60", "", "", "89.4", "80.4", "", "58.7", "", "2", "1", "", "102", "1", "2", "84", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.4", "99.8", "", "", "", "", "98.0"]} +{"pcdb_id": 9300, "brand_name": "Ideal", "model_name": "Imax", "model_qualifier": "W45", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 45.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009300", "000008", "0", "2012/Mar/27 10:12", "Ideal Boilers", "Ideal", "Imax", "W45", "PI No 0063BN3218", "2002", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "45", "45", "", "", "88.2", "79.2", "", "57.9", "", "2", "", "", "102", "1", "2", "51", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.5", "97.2", "", "", "", "", "95.6"]} +{"pcdb_id": 9301, "brand_name": "Turkington Engineering", "model_name": "Eurocal Boiler House", "model_qualifier": "115/140/2", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 41.03, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009301", "000218", "0", "2012/Mar/27 10:12", "Turkington Engineering", "Turkington Engineering", "Eurocal Boiler House", "115/140/2", "", "1996", "current", "4", "1", "2", "1", "0", "", "", "1", "0", "1", "33.7", "41.03", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.6", "87.7", "", "", "", "", "87.7"]} +{"pcdb_id": 9303, "brand_name": "Turkington Engineering", "model_name": "Eurocal White Cased Kitchen", "model_qualifier": "115/140", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 41.03, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009303", "000218", "0", "2012/Mar/27 10:12", "Turkington Engineering", "Turkington Engineering", "Eurocal White Cased Kitchen", "115/140", "", "1996", "current", "4", "1", "2", "1", "0", "", "", "1", "0", "1", "33.7", "41.03", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.6", "87.7", "", "", "", "", "87.7"]} +{"pcdb_id": 9305, "brand_name": "Turkington Engineering", "model_name": "Turco 2000 White Cased", "model_qualifier": "115/140", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 41.03, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009305", "000218", "0", "2012/Mar/27 10:12", "Turkington Engineering", "Turkington Engineering", "Turco 2000 White Cased", "115/140", "", "1996", "current", "4", "1", "2", "1", "0", "", "", "1", "0", "1", "33.7", "41.03", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.6", "87.7", "", "", "", "", "87.7"]} +{"pcdb_id": 9307, "brand_name": "Turkington Engineering", "model_name": "Turco 2000 Boiler House", "model_qualifier": "115/140", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 41.03, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009307", "000218", "0", "2012/Mar/27 10:12", "Turkington Engineering", "Turkington Engineering", "Turco 2000 Boiler House", "115/140", "", "1996", "current", "4", "1", "2", "1", "0", "", "", "1", "0", "1", "33.7", "41.03", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.6", "87.7", "", "", "", "", "87.7"]} +{"pcdb_id": 9309, "brand_name": "Turkington Engineering", "model_name": "Eurocal Boiler House", "model_qualifier": "140/170/2", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 52.75, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009309", "000218", "0", "2012/Mar/27 10:12", "Turkington Engineering", "Turkington Engineering", "Eurocal Boiler House", "140/170/2", "", "1996", "current", "4", "1", "2", "1", "0", "", "", "1", "0", "1", "41.03", "52.75", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.9", "87.7", "", "", "", "", "87.5"]} +{"pcdb_id": 9311, "brand_name": "Turkington Engineering", "model_name": "Eurocal White Cased Kitchen", "model_qualifier": "140/170", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 52.75, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009311", "000218", "0", "2012/Mar/27 10:12", "Turkington Engineering", "Turkington Engineering", "Eurocal White Cased Kitchen", "140/170", "", "1996", "current", "4", "1", "2", "1", "0", "", "", "1", "0", "1", "41.03", "52.75", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.9", "87.7", "", "", "", "", "87.5"]} +{"pcdb_id": 9313, "brand_name": "Turkington Engineering", "model_name": "Turco 2000 White Cased", "model_qualifier": "140/170", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 52.75, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009313", "000218", "0", "2012/Mar/27 10:12", "Turkington Engineering", "Turkington Engineering", "Turco 2000 White Cased", "140/170", "", "1996", "current", "4", "1", "2", "1", "0", "", "", "1", "0", "1", "41.03", "52.75", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.9", "87.7", "", "", "", "", "87.5"]} +{"pcdb_id": 9316, "brand_name": "Turkington Engineering", "model_name": "Turco 2000 Boiler House", "model_qualifier": "140/170", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 52.75, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009316", "000218", "0", "2012/Mar/27 10:12", "Turkington Engineering", "Turkington Engineering", "Turco 2000 Boiler House", "140/170", "", "1996", "current", "4", "1", "2", "1", "0", "", "", "1", "0", "1", "41.03", "52.75", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.9", "87.7", "", "", "", "", "87.5"]} +{"pcdb_id": 9318, "brand_name": "Turkington Engineering", "model_name": "Turco 2000 Outdoor System", "model_qualifier": "90/115", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 33.7, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009318", "000218", "0", "2012/Mar/27 10:12", "Turkington Engineering", "Turkington Engineering", "Turco 2000 Outdoor System", "90/115", "", "1996", "current", "4", "1", "2", "1", "0", "", "", "1", "0", "1", "26.37", "33.7", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.2", "87.7", "", "", "", "", "87.6"]} +{"pcdb_id": 9320, "brand_name": "Turkington Engineering", "model_name": "Turco 2000 White System", "model_qualifier": "90/115", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 33.7, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009320", "000218", "0", "2012/Mar/27 10:12", "Turkington Engineering", "Turkington Engineering", "Turco 2000 White System", "90/115", "", "1996", "current", "4", "1", "2", "1", "0", "", "", "1", "0", "1", "26.37", "33.7", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.2", "87.7", "", "", "", "", "87.6"]} +{"pcdb_id": 9322, "brand_name": "Turkington Engineering", "model_name": "Turco 2000 Outdoor", "model_qualifier": "90/115", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 33.7, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009322", "000218", "0", "2012/Mar/27 10:12", "Turkington Engineering", "Turkington Engineering", "Turco 2000 Outdoor", "90/115", "", "1996", "current", "4", "1", "2", "1", "0", "", "", "1", "0", "1", "26.37", "33.7", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.2", "87.7", "", "", "", "", "87.6"]} +{"pcdb_id": 9324, "brand_name": "Turkington Engineering", "model_name": "Turco 2000 Boiler House", "model_qualifier": "90/115", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 33.7, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009324", "000218", "0", "2012/Mar/27 10:12", "Turkington Engineering", "Turkington Engineering", "Turco 2000 Boiler House", "90/115", "", "1996", "current", "4", "1", "2", "1", "0", "", "", "1", "0", "1", "26.37", "33.7", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.2", "87.7", "", "", "", "", "87.6"]} +{"pcdb_id": 9326, "brand_name": "Turkington Engineering", "model_name": "Turco 2000 White Cased", "model_qualifier": "90/115", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 33.7, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009326", "000218", "0", "2012/Mar/27 10:12", "Turkington Engineering", "Turkington Engineering", "Turco 2000 White Cased", "90/115", "", "1996", "current", "4", "1", "2", "1", "0", "", "", "1", "0", "1", "26.37", "33.7", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.2", "87.7", "", "", "", "", "87.6"]} +{"pcdb_id": 9328, "brand_name": "Turkington Engineering", "model_name": "Eurocal Outdoor System", "model_qualifier": "90/115", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 33.7, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009328", "000218", "0", "2012/Mar/27 10:12", "Turkington Engineering", "Turkington Engineering", "Eurocal Outdoor System", "90/115", "", "1996", "current", "4", "1", "2", "1", "0", "", "", "1", "0", "1", "26.37", "33.7", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.2", "87.7", "", "", "", "", "87.6"]} +{"pcdb_id": 9330, "brand_name": "Turkington Engineering", "model_name": "Eurocal White Cased System", "model_qualifier": "90/115", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 33.7, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009330", "000218", "0", "2012/Mar/27 10:12", "Turkington Engineering", "Turkington Engineering", "Eurocal White Cased System", "90/115", "", "1996", "current", "4", "1", "2", "1", "0", "", "", "1", "0", "1", "26.37", "33.7", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.2", "87.7", "", "", "", "", "87.6"]} +{"pcdb_id": 9332, "brand_name": "Turkington Engineering", "model_name": "Eurocal Outdoor", "model_qualifier": "90/115", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 33.7, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009332", "000218", "0", "2012/Mar/27 10:12", "Turkington Engineering", "Turkington Engineering", "Eurocal Outdoor", "90/115", "", "1996", "current", "4", "1", "2", "1", "0", "", "", "1", "0", "1", "26.37", "33.7", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.2", "87.7", "", "", "", "", "87.6"]} +{"pcdb_id": 9334, "brand_name": "Turkington Engineering", "model_name": "Eurocal White Cased Kitchen", "model_qualifier": "90/115", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 33.7, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009334", "000218", "0", "2012/Mar/27 10:12", "Turkington Engineering", "Turkington Engineering", "Eurocal White Cased Kitchen", "90/115", "", "1996", "current", "4", "1", "2", "1", "0", "", "", "1", "0", "1", "26.37", "33.7", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.2", "87.7", "", "", "", "", "87.6"]} +{"pcdb_id": 9336, "brand_name": "Turkington Engineering", "model_name": "Eurocal Boiler House", "model_qualifier": "90/115/2", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 33.7, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009336", "000218", "0", "2012/Mar/27 10:12", "Turkington Engineering", "Turkington Engineering", "Eurocal Boiler House", "90/115/2", "", "1996", "current", "4", "1", "2", "1", "0", "", "", "1", "0", "1", "26.37", "33.7", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.2", "87.7", "", "", "", "", "87.6"]} +{"pcdb_id": 9338, "brand_name": "Turkington Engineering", "model_name": "Turco 2000 Outdoor Combi", "model_qualifier": "90/115", "winter_efficiency_pct": 84.9, "summer_efficiency_pct": 75.4, "comparative_hot_water_efficiency_pct": 53.0, "output_kw_max": 33.7, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009338", "000218", "0", "2003/Jan/13 11:46", "Turkington Engineering", "Turkington Engineering", "Turco 2000 Outdoor Combi", "90/115", "", "1996", "current", "4", "1", "2", "2", "0", "", "", "1", "0", "1", "26.37", "33.7", "", "", "84.9", "75.4", "", "53.0", "", "2", "", "", "202", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.2", "87.7", "", "", "", "", "87.6"]} +{"pcdb_id": 9340, "brand_name": "Turkington Engineering", "model_name": "Turco 2000 White Combi", "model_qualifier": "90/115", "winter_efficiency_pct": 84.9, "summer_efficiency_pct": 75.4, "comparative_hot_water_efficiency_pct": 53.0, "output_kw_max": 33.7, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009340", "000218", "0", "2003/Jan/13 11:47", "Turkington Engineering", "Turkington Engineering", "Turco 2000 White Combi", "90/115", "", "1996", "current", "4", "1", "2", "2", "0", "", "", "1", "0", "1", "26.37", "33.7", "", "", "84.9", "75.4", "", "53.0", "", "2", "", "", "202", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.2", "87.7", "", "", "", "", "87.6"]} +{"pcdb_id": 9342, "brand_name": "Turkington Engineering", "model_name": "Eurocal White Cased Combi", "model_qualifier": "90/115", "winter_efficiency_pct": 84.9, "summer_efficiency_pct": 75.4, "comparative_hot_water_efficiency_pct": 53.0, "output_kw_max": 33.7, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009342", "000218", "0", "2003/Jan/13 11:47", "Turkington Engineering", "Turkington Engineering", "Eurocal White Cased Combi", "90/115", "", "1996", "current", "4", "1", "2", "2", "0", "", "", "1", "0", "1", "26.37", "33.7", "", "", "84.9", "75.4", "", "53.0", "", "2", "", "", "202", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.2", "87.7", "", "", "", "", "87.6"]} +{"pcdb_id": 9344, "brand_name": "Turkington Engineering", "model_name": "Eurocal Outdoor Combi", "model_qualifier": "90/115", "winter_efficiency_pct": 84.9, "summer_efficiency_pct": 75.4, "comparative_hot_water_efficiency_pct": 53.0, "output_kw_max": 33.7, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009344", "000218", "0", "2003/Jan/13 11:48", "Turkington Engineering", "Turkington Engineering", "Eurocal Outdoor Combi", "90/115", "", "1996", "current", "4", "1", "2", "2", "0", "", "", "1", "0", "1", "26.37", "33.7", "", "", "84.9", "75.4", "", "53.0", "", "2", "", "", "202", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.2", "87.7", "", "", "", "", "87.6"]} +{"pcdb_id": 9347, "brand_name": "Turkington Engineering", "model_name": "Eurocal Boiler House", "model_qualifier": "70/90", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 26.37, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009347", "000218", "0", "2012/Mar/27 10:12", "Turkington Engineering", "Turkington Engineering", "Eurocal Boiler House", "70/90", "", "1996", "current", "4", "1", "2", "1", "0", "", "", "1", "0", "1", "20.5", "26.37", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.2", "87.7", "", "", "", "", "87.6"]} +{"pcdb_id": 9349, "brand_name": "Turkington Engineering", "model_name": "Eurocal White Cased Kitchen", "model_qualifier": "70/90", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 26.37, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009349", "000218", "0", "2012/Mar/27 10:12", "Turkington Engineering", "Turkington Engineering", "Eurocal White Cased Kitchen", "70/90", "", "1996", "current", "4", "1", "2", "1", "0", "", "", "1", "0", "1", "20.5", "26.37", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.2", "87.7", "", "", "", "", "87.6"]} +{"pcdb_id": 9351, "brand_name": "Turkington Engineering", "model_name": "Eurocal Outdoor", "model_qualifier": "70/90", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 26.37, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009351", "000218", "0", "2012/Mar/27 10:12", "Turkington Engineering", "Turkington Engineering", "Eurocal Outdoor", "70/90", "", "1996", "current", "4", "1", "2", "1", "0", "", "", "1", "0", "1", "20.5", "26.37", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.2", "87.7", "", "", "", "", "87.6"]} +{"pcdb_id": 9353, "brand_name": "Turkington Engineering", "model_name": "Eurocal White Cased System", "model_qualifier": "70/90", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 26.37, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009353", "000218", "0", "2012/Mar/27 10:12", "Turkington Engineering", "Turkington Engineering", "Eurocal White Cased System", "70/90", "", "1996", "current", "4", "1", "2", "1", "0", "", "", "1", "0", "1", "20.5", "26.37", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.2", "87.7", "", "", "", "", "87.6"]} +{"pcdb_id": 9355, "brand_name": "Turkington Engineering", "model_name": "Eurocal Outdoor System", "model_qualifier": "70/90", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 26.37, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009355", "000218", "0", "2012/Mar/27 10:12", "Turkington Engineering", "Turkington Engineering", "Eurocal Outdoor System", "70/90", "", "1996", "current", "4", "1", "2", "1", "0", "", "", "1", "0", "1", "20.5", "26.37", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.2", "87.7", "", "", "", "", "87.6"]} +{"pcdb_id": 9357, "brand_name": "Turkington Engineering", "model_name": "Turco 2000 White Cased", "model_qualifier": "70/90", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 26.37, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009357", "000218", "0", "2012/Mar/27 10:12", "Turkington Engineering", "Turkington Engineering", "Turco 2000 White Cased", "70/90", "", "1996", "current", "4", "1", "2", "1", "0", "", "", "1", "0", "1", "20.5", "26.37", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.2", "87.7", "", "", "", "", "87.6"]} +{"pcdb_id": 9359, "brand_name": "Turkington Engineering", "model_name": "Turco 2000 Boiler House", "model_qualifier": "70/90", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 26.37, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009359", "000218", "0", "2012/Mar/27 10:12", "Turkington Engineering", "Turkington Engineering", "Turco 2000 Boiler House", "70/90", "", "1996", "current", "4", "1", "2", "1", "0", "", "", "1", "0", "1", "20.5", "26.37", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.2", "87.7", "", "", "", "", "87.6"]} +{"pcdb_id": 9361, "brand_name": "Turkington Engineering", "model_name": "Turco 2000 Outdoor", "model_qualifier": "70/90", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 26.37, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009361", "000218", "0", "2012/Mar/27 10:12", "Turkington Engineering", "Turkington Engineering", "Turco 2000 Outdoor", "70/90", "", "1996", "current", "4", "1", "2", "1", "0", "", "", "1", "0", "1", "20.5", "26.37", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.2", "87.7", "", "", "", "", "87.6"]} +{"pcdb_id": 9363, "brand_name": "Turkington Engineering", "model_name": "Turco 2000 White Cased System", "model_qualifier": "70/90", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 26.37, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009363", "000218", "0", "2012/Mar/27 10:12", "Turkington Engineering", "Turkington Engineering", "Turco 2000 White Cased System", "70/90", "", "1996", "current", "4", "1", "2", "1", "0", "", "", "1", "0", "1", "20.5", "26.37", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.2", "87.7", "", "", "", "", "87.6"]} +{"pcdb_id": 9365, "brand_name": "Turkington Engineering", "model_name": "Turco 2000 Outdoor System", "model_qualifier": "70/90", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 26.37, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009365", "000218", "0", "2012/Mar/27 10:12", "Turkington Engineering", "Turkington Engineering", "Turco 2000 Outdoor System", "70/90", "", "1996", "current", "4", "1", "2", "1", "0", "", "", "1", "0", "1", "20.5", "26.37", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.2", "87.7", "", "", "", "", "87.6"]} +{"pcdb_id": 9369, "brand_name": "Turkington Engineering", "model_name": "Eurocal Outdoor Combi", "model_qualifier": "70/90", "winter_efficiency_pct": 84.9, "summer_efficiency_pct": 75.4, "comparative_hot_water_efficiency_pct": 53.0, "output_kw_max": 26.37, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009369", "000218", "0", "2003/Jan/13 12:03", "Turkington Engineering", "Turkington Engineering", "Eurocal Outdoor Combi", "70/90", "", "1996", "current", "4", "1", "2", "2", "0", "", "", "1", "0", "1", "20.5", "26.37", "", "", "84.9", "75.4", "", "53.0", "", "2", "", "", "202", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.2", "87.7", "", "", "", "", "87.6"]} +{"pcdb_id": 9371, "brand_name": "Turkington Engineering", "model_name": "Eurocal white Cased Combi", "model_qualifier": "70/90", "winter_efficiency_pct": 84.9, "summer_efficiency_pct": 75.4, "comparative_hot_water_efficiency_pct": 53.0, "output_kw_max": 26.37, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009371", "000218", "0", "2003/Jan/13 12:04", "Turkington Engineering", "Turkington Engineering", "Eurocal white Cased Combi", "70/90", "", "1996", "current", "4", "1", "2", "2", "0", "", "", "1", "0", "1", "20.5", "26.37", "", "", "84.9", "75.4", "", "53.0", "", "2", "", "", "202", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.2", "87.7", "", "", "", "", "87.6"]} +{"pcdb_id": 9373, "brand_name": "Turkington Engineering", "model_name": "Turco 2000 White Cased Combi", "model_qualifier": "70/90", "winter_efficiency_pct": 84.9, "summer_efficiency_pct": 75.4, "comparative_hot_water_efficiency_pct": 53.0, "output_kw_max": 26.37, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009373", "000218", "0", "2003/Jan/13 12:04", "Turkington Engineering", "Turkington Engineering", "Turco 2000 White Cased Combi", "70/90", "", "1996", "current", "4", "1", "2", "2", "0", "", "", "1", "0", "1", "20.5", "26.37", "", "", "84.9", "75.4", "", "53.0", "", "2", "", "", "202", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.2", "87.7", "", "", "", "", "87.6"]} +{"pcdb_id": 9375, "brand_name": "Turkington Engineering", "model_name": "Turco 2000 Outdoor Combi", "model_qualifier": "70/90", "winter_efficiency_pct": 84.9, "summer_efficiency_pct": 75.4, "comparative_hot_water_efficiency_pct": 53.0, "output_kw_max": 26.37, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009375", "000218", "0", "2003/Jan/13 12:05", "Turkington Engineering", "Turkington Engineering", "Turco 2000 Outdoor Combi", "70/90", "", "1996", "current", "4", "1", "2", "2", "0", "", "", "1", "0", "1", "20.5", "26.37", "", "", "84.9", "75.4", "", "53.0", "", "2", "", "", "202", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.2", "87.7", "", "", "", "", "87.6"]} +{"pcdb_id": 9377, "brand_name": "Turkington Engineering", "model_name": "Eurocal Boiler House", "model_qualifier": "50/70/2", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 20.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009377", "000218", "0", "2012/Mar/27 10:12", "Turkington Engineering", "Turkington Engineering", "Eurocal Boiler House", "50/70/2", "", "1996", "current", "4", "1", "2", "1", "0", "", "", "1", "0", "1", "14.65", "20.5", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.2", "87.7", "", "", "", "", "87.6"]} +{"pcdb_id": 9379, "brand_name": "Turkington Engineering", "model_name": "Eurocal White Cased Kitchen", "model_qualifier": "50/70", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 20.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009379", "000218", "0", "2012/Mar/27 10:12", "Turkington Engineering", "Turkington Engineering", "Eurocal White Cased Kitchen", "50/70", "", "1996", "current", "4", "1", "2", "1", "0", "", "", "1", "0", "1", "14.65", "20.5", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.2", "87.7", "", "", "", "", "87.6"]} +{"pcdb_id": 9381, "brand_name": "Turkington Engineering", "model_name": "Eurocal Outdoor", "model_qualifier": "50/70", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 20.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009381", "000218", "0", "2012/Mar/27 10:12", "Turkington Engineering", "Turkington Engineering", "Eurocal Outdoor", "50/70", "", "1996", "current", "4", "1", "2", "1", "0", "", "", "1", "0", "1", "14.65", "20.5", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.2", "87.7", "", "", "", "", "87.6"]} +{"pcdb_id": 9383, "brand_name": "Turkington Engineering", "model_name": "Eurocal White Cased System", "model_qualifier": "50/70", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 20.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009383", "000218", "0", "2012/Mar/27 10:12", "Turkington Engineering", "Turkington Engineering", "Eurocal White Cased System", "50/70", "", "1996", "current", "4", "1", "2", "1", "0", "", "", "1", "0", "1", "14.65", "20.50", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.2", "87.7", "", "", "", "", "87.6"]} +{"pcdb_id": 9385, "brand_name": "Turkington Engineering", "model_name": "Eurocal Outdoor System", "model_qualifier": "50/70", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 20.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009385", "000218", "0", "2012/Mar/27 10:12", "Turkington Engineering", "Turkington Engineering", "Eurocal Outdoor System", "50/70", "", "1996", "current", "4", "1", "2", "1", "0", "", "", "1", "0", "1", "14.65", "20.50", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.2", "87.7", "", "", "", "", "87.6"]} +{"pcdb_id": 9387, "brand_name": "Turkington Engineering", "model_name": "Turco 2000 White Cased", "model_qualifier": "50/70", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 20.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009387", "000218", "0", "2012/Mar/27 10:12", "Turkington Engineering", "Turkington Engineering", "Turco 2000 White Cased", "50/70", "", "1996", "current", "4", "1", "2", "1", "0", "", "", "1", "0", "1", "14.65", "20.50", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.2", "87.7", "", "", "", "", "87.6"]} +{"pcdb_id": 9389, "brand_name": "Turkington Engineering", "model_name": "Turco 2000 Boiler House", "model_qualifier": "50/70", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 20.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009389", "000218", "0", "2012/Mar/27 10:12", "Turkington Engineering", "Turkington Engineering", "Turco 2000 Boiler House", "50/70", "", "1996", "current", "4", "1", "2", "1", "0", "", "", "1", "0", "1", "14.65", "20.50", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.2", "87.7", "", "", "", "", "87.6"]} +{"pcdb_id": 9391, "brand_name": "Turkington Engineering", "model_name": "Turco 2000 Outdoor", "model_qualifier": "50/70", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 20.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009391", "000218", "0", "2012/Mar/27 10:12", "Turkington Engineering", "Turkington Engineering", "Turco 2000 Outdoor", "50/70", "", "1996", "current", "4", "1", "2", "1", "0", "", "", "1", "0", "1", "14.65", "20.50", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.2", "87.7", "", "", "", "", "87.6"]} +{"pcdb_id": 9393, "brand_name": "Turkington Engineering", "model_name": "Turco 2000 White System", "model_qualifier": "50/70", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 20.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009393", "000218", "0", "2012/Mar/27 10:12", "Turkington Engineering", "Turkington Engineering", "Turco 2000 White System", "50/70", "", "1996", "current", "4", "1", "2", "1", "0", "", "", "1", "0", "1", "14.65", "20.50", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.2", "87.7", "", "", "", "", "87.6"]} +{"pcdb_id": 9395, "brand_name": "Turkington Engineering", "model_name": "Turco 2000 Outdoor System", "model_qualifier": "50/70", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 20.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009395", "000218", "0", "2012/Mar/27 10:12", "Turkington Engineering", "Turkington Engineering", "Turco 2000 Outdoor System", "50/70", "", "1996", "current", "4", "1", "2", "1", "0", "", "", "1", "0", "1", "14.65", "20.50", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.2", "87.7", "", "", "", "", "87.6"]} +{"pcdb_id": 9397, "brand_name": "Turkington Engineering", "model_name": "Eurocal White Cased Combi", "model_qualifier": "50/70", "winter_efficiency_pct": 84.9, "summer_efficiency_pct": 75.4, "comparative_hot_water_efficiency_pct": 53.0, "output_kw_max": 20.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009397", "000218", "0", "2003/Jan/13 12:13", "Turkington Engineering", "Turkington Engineering", "Eurocal White Cased Combi", "50/70", "", "1996", "current", "4", "1", "2", "2", "0", "", "", "1", "0", "1", "14.65", "20.50", "", "", "84.9", "75.4", "", "53.0", "", "2", "", "", "202", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.2", "87.7", "", "", "", "", "87.6"]} +{"pcdb_id": 9399, "brand_name": "Turkington Engineering", "model_name": "Eurocal Outdoor Combi", "model_qualifier": "50/70", "winter_efficiency_pct": 84.9, "summer_efficiency_pct": 75.4, "comparative_hot_water_efficiency_pct": 53.0, "output_kw_max": 20.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009399", "000218", "0", "2003/Jan/13 12:13", "Turkington Engineering", "Turkington Engineering", "Eurocal Outdoor Combi", "50/70", "", "1996", "current", "4", "1", "2", "2", "0", "", "", "1", "0", "1", "14.65", "20.50", "", "", "84.9", "75.4", "", "53.0", "", "2", "", "", "202", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.2", "87.7", "", "", "", "", "87.6"]} +{"pcdb_id": 9403, "brand_name": "Turkington Engineering", "model_name": "Turco 2000 White Combi", "model_qualifier": "50/70", "winter_efficiency_pct": 84.9, "summer_efficiency_pct": 75.4, "comparative_hot_water_efficiency_pct": 53.0, "output_kw_max": 20.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009403", "000218", "0", "2003/Jan/13 12:14", "Turkington Engineering", "Turkington Engineering", "Turco 2000 White Combi", "50/70", "", "1996", "current", "4", "1", "2", "2", "0", "", "", "1", "0", "1", "14.65", "20.50", "", "", "84.9", "75.4", "", "53.0", "", "2", "", "", "202", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.2", "87.7", "", "", "", "", "87.6"]} +{"pcdb_id": 9405, "brand_name": "Turkington Engineering", "model_name": "Turco 2000 Outdoor Combi", "model_qualifier": "50/70", "winter_efficiency_pct": 84.9, "summer_efficiency_pct": 75.4, "comparative_hot_water_efficiency_pct": 53.0, "output_kw_max": 20.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009405", "000218", "0", "2003/Jan/13 12:14", "Turkington Engineering", "Turkington Engineering", "Turco 2000 Outdoor Combi", "50/70", "", "1996", "current", "4", "1", "2", "2", "0", "", "", "1", "0", "1", "14.65", "20.50", "", "", "84.9", "75.4", "", "53.0", "", "2", "", "", "202", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.2", "87.7", "", "", "", "", "87.6"]} +{"pcdb_id": 9407, "brand_name": "Ravenheat", "model_name": "CSI System A T", "model_qualifier": "", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 80.4, "comparative_hot_water_efficiency_pct": 58.7, "output_kw_max": 22.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009407", "000026", "0", "2012/Mar/27 10:12", "Ravenheat", "Ravenheat", "CSI System A T", "", "", "2002", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "22.3", "22.3", "", "", "89.4", "80.4", "", "58.7", "", "2", "", "", "102", "1", "2", "160", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.9", "100.0", "", "", "", "", "97.9"]} +{"pcdb_id": 9408, "brand_name": "Ravenheat", "model_name": "CSI System A", "model_qualifier": "", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 80.4, "comparative_hot_water_efficiency_pct": 58.7, "output_kw_max": 22.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009408", "000026", "0", "2012/Mar/27 10:12", "Ravenheat", "Ravenheat", "CSI System A", "", "", "2002", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "22.3", "22.3", "", "", "89.4", "80.4", "", "58.7", "", "2", "", "", "102", "1", "2", "160", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.9", "100.0", "", "", "", "", "97.9"]} +{"pcdb_id": 9409, "brand_name": "Ravenheat", "model_name": "CSI Primary A", "model_qualifier": "", "winter_efficiency_pct": 87.2, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 22.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009409", "000026", "0", "2012/Mar/27 10:12", "Ravenheat", "Ravenheat", "CSI Primary A", "", "", "2002", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "10.6", "22.3", "", "", "87.2", "79.6", "", "58.2", "", "2", "", "", "101", "1", "1", "60", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "88.9", "98.0", "", "", "", "", "96.3"]} +{"pcdb_id": 9410, "brand_name": "Ravenheat", "model_name": "CSI 85 A", "model_qualifier": "", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 56.8, "output_kw_max": 22.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009410", "000026", "0", "2006/Jan/17 12:31", "Ravenheat", "Ravenheat", "CSI 85 A", "", "", "2002", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "22.3", "22.3", "", "", "89.4", "80.8", "", "56.8", "", "2", "", "", "104", "1", "2", "160", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "", "", "0005", "", "", "", "", "", "", "", "", "88.9", "100.0", "", "", "", "", "97.9"]} +{"pcdb_id": 9411, "brand_name": "Ravenheat", "model_name": "CSI 85 A T", "model_qualifier": "", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 56.8, "output_kw_max": 22.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009411", "000026", "0", "2006/Jan/17 12:31", "Ravenheat", "Ravenheat", "CSI 85 A T", "", "", "2002", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "22.3", "22.3", "", "", "89.4", "80.8", "", "56.8", "", "2", "", "", "104", "1", "2", "160", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "", "", "0005", "", "", "", "", "", "", "", "", "88.9", "100.0", "", "", "", "", "97.9"]} +{"pcdb_id": 9412, "brand_name": "Ravenheat", "model_name": "CSI System A", "model_qualifier": "", "winter_efficiency_pct": 90.6, "summer_efficiency_pct": 81.6, "comparative_hot_water_efficiency_pct": 59.6, "output_kw_max": 22.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009412", "000026", "0", "2012/Mar/27 10:12", "Ravenheat", "Ravenheat", "CSI System A", "", "", "2002", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "22.3", "22.3", "", "", "90.6", "81.6", "", "59.6", "", "2", "0", "", "102", "1", "2", "160", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.9", "100.1", "", "", "", "", "98.4"]} +{"pcdb_id": 9413, "brand_name": "Ravenheat", "model_name": "CSI System A T", "model_qualifier": "", "winter_efficiency_pct": 90.6, "summer_efficiency_pct": 81.6, "comparative_hot_water_efficiency_pct": 59.6, "output_kw_max": 22.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009413", "000026", "0", "2012/Mar/27 10:12", "Ravenheat", "Ravenheat", "CSI System A T", "", "", "2002", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "22.3", "22.3", "", "", "90.6", "81.6", "", "59.6", "", "2", "0", "", "102", "1", "2", "160", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.9", "100.1", "", "", "", "", "98.4"]} +{"pcdb_id": 9414, "brand_name": "Ravenheat", "model_name": "CSI Primary A", "model_qualifier": "", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 81.6, "comparative_hot_water_efficiency_pct": 59.6, "output_kw_max": 22.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009414", "000026", "0", "2012/Mar/27 10:12", "Ravenheat", "Ravenheat", "CSI Primary A", "", "", "2002", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "10.6", "22.3", "", "", "89.2", "81.6", "", "59.6", "", "2", "0", "", "101", "1", "1", "60", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.9", "100.1", "", "", "", "", "98.4"]} +{"pcdb_id": 9415, "brand_name": "Ravenheat", "model_name": "CSI 85 A T", "model_qualifier": "", "winter_efficiency_pct": 90.6, "summer_efficiency_pct": 82.0, "comparative_hot_water_efficiency_pct": 57.6, "output_kw_max": 22.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009415", "000026", "0", "2006/Jan/17 12:31", "Ravenheat", "Ravenheat", "CSI 85 A T", "", "", "2002", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "22.3", "22.3", "", "", "90.6", "82.0", "", "57.6", "", "2", "0", "", "104", "1", "2", "160", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "", "", "0005", "", "", "", "", "", "", "", "", "90.9", "100.1", "", "", "", "", "98.4"]} +{"pcdb_id": 9416, "brand_name": "Ravenheat", "model_name": "CSI 85 A", "model_qualifier": "", "winter_efficiency_pct": 90.6, "summer_efficiency_pct": 82.0, "comparative_hot_water_efficiency_pct": 57.6, "output_kw_max": 22.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009416", "000026", "0", "2006/Jan/17 12:31", "Ravenheat", "Ravenheat", "CSI 85 A", "", "", "2002", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "22.3", "22.3", "", "", "90.6", "82.0", "", "57.6", "", "2", "0", "", "104", "1", "2", "160", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "", "", "0005", "", "", "", "", "", "", "", "", "90.9", "100.1", "", "", "", "", "98.4"]} +{"pcdb_id": 9417, "brand_name": "MHS Boilers", "model_name": "Stata Streamline", "model_qualifier": "68", "winter_efficiency_pct": 87.7, "summer_efficiency_pct": 78.7, "comparative_hot_water_efficiency_pct": 57.5, "output_kw_max": 67.8, "final_year_of_manufacture": 2004, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009417", "000024", "0", "2012/Mar/27 10:12", "MHS Boilers", "MHS Boilers", "Stata Streamline", "68", "", "2002", "2004", "1", "2", "1", "1", "0", "", "", "2", "3", "1", "67.8", "67.8", "", "", "87.7", "78.7", "", "57.5", "", "2", "", "", "102", "1", "2", "60", "6", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.3", "96.2", "", "", "", "", "94.5"]} +{"pcdb_id": 9419, "brand_name": "Aquaflame", "model_name": "Evolution II 110", "model_qualifier": "", "winter_efficiency_pct": 85.7, "summer_efficiency_pct": 74.0, "comparative_hot_water_efficiency_pct": 54.0, "output_kw_max": 33.1, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009419", "000039", "0", "2012/Mar/27 10:12", "Aquaflame", "Aquaflame", "Evolution II 110", "", "", "2002", "current", "4", "1", "1", "1", "0", "", "", "1", "3", "1", "33.1", "33.1", "", "", "85.7", "74.0", "", "54.0", "", "2", "", "", "201", "1", "1", "100", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.7", "85.6", "", "", "", "", "85.7"]} +{"pcdb_id": 9422, "brand_name": "Aquaflame", "model_name": "Evolution II 95", "model_qualifier": "", "winter_efficiency_pct": 85.1, "summer_efficiency_pct": 73.4, "comparative_hot_water_efficiency_pct": 53.6, "output_kw_max": 27.1, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009422", "000039", "0", "2012/Mar/27 10:12", "Aquaflame", "Aquaflame", "Evolution II 95", "", "", "2002", "current", "4", "1", "1", "1", "0", "", "", "1", "3", "1", "27.1", "27.1", "", "", "85.1", "73.4", "", "53.6", "", "2", "", "", "201", "1", "1", "100", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.1", "85.1", "", "", "", "", "85.1"]} +{"pcdb_id": 9424, "brand_name": "Aquaflame", "model_name": "Evolution II 80", "model_qualifier": "", "winter_efficiency_pct": 85.0, "summer_efficiency_pct": 73.3, "comparative_hot_water_efficiency_pct": 53.6, "output_kw_max": 22.1, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009424", "000039", "0", "2012/Mar/27 10:12", "Aquaflame", "Aquaflame", "Evolution II 80", "", "", "2002", "current", "4", "1", "1", "1", "0", "", "", "1", "3", "1", "22.1", "22.1", "", "", "85.0", "73.3", "", "53.6", "", "2", "", "", "201", "1", "1", "100", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "84.7", "85.4", "", "", "", "", "85.2"]} +{"pcdb_id": 9425, "brand_name": "Aquaflame", "model_name": "Evolution II 65", "model_qualifier": "", "winter_efficiency_pct": 85.0, "summer_efficiency_pct": 73.3, "comparative_hot_water_efficiency_pct": 53.6, "output_kw_max": 18.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009425", "000039", "0", "2012/Mar/27 10:12", "Aquaflame", "Aquaflame", "Evolution II 65", "", "", "2002", "current", "4", "1", "1", "1", "0", "", "", "1", "3", "1", "18.2", "18.2", "", "", "85.0", "73.3", "", "53.6", "", "2", "", "", "201", "1", "1", "100", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "84.8", "85.3", "", "", "", "", "85.2"]} +{"pcdb_id": 9428, "brand_name": "Aquaflame", "model_name": "Evolution II 50", "model_qualifier": "", "winter_efficiency_pct": 85.0, "summer_efficiency_pct": 73.3, "comparative_hot_water_efficiency_pct": 53.6, "output_kw_max": 14.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009428", "000039", "0", "2012/Mar/27 10:12", "Aquaflame", "Aquaflame", "Evolution II 50", "", "", "2002", "current", "4", "1", "1", "1", "0", "", "", "1", "3", "1", "14.4", "14.4", "", "", "85.0", "73.3", "", "53.6", "", "2", "", "", "201", "1", "1", "100", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "84.8", "85.3", "", "", "", "", "85.2"]} +{"pcdb_id": 9430, "brand_name": "Aquaflame", "model_name": "Eco-Avance II 15", "model_qualifier": "", "winter_efficiency_pct": 87.1, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 15.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009430", "000039", "0", "2012/Mar/27 10:12", "Aquaflame", "Aquaflame", "Eco-Avance II 15", "", "", "2002", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "15", "15.0", "", "", "87.1", "79.3", "", "58.0", "", "2", "", "", "201", "1", "1", "100", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.4", "92.8", "", "", "", "", "92.3"]} +{"pcdb_id": 9432, "brand_name": "Aquaflame", "model_name": "Eco-Avance II 19", "model_qualifier": "", "winter_efficiency_pct": 87.1, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 19.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009432", "000039", "0", "2012/Mar/27 10:12", "Aquaflame", "Aquaflame", "Eco-Avance II 19", "", "", "2002", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "19.3", "19.3", "", "", "87.1", "79.3", "", "58.0", "", "2", "", "", "201", "1", "1", "100", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.4", "92.8", "", "", "", "", "92.3"]} +{"pcdb_id": 9433, "brand_name": "Aquaflame", "model_name": "Eco-Avance II 24", "model_qualifier": "", "winter_efficiency_pct": 87.3, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 24.1, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009433", "000039", "0", "2012/Mar/27 10:12", "Aquaflame", "Aquaflame", "Eco-Avance II 24", "", "", "2002", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "24.1", "24.1", "", "", "87.3", "79.5", "", "58.0", "", "2", "", "", "201", "1", "1", "100", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.2", "93.1", "", "", "", "", "92.6"]} +{"pcdb_id": 9436, "brand_name": "Aquaflame", "model_name": "Eco-Avance II 27", "model_qualifier": "", "winter_efficiency_pct": 87.3, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 27.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009436", "000039", "0", "2012/Mar/27 10:12", "Aquaflame", "Aquaflame", "Eco-Avance II 27", "", "", "2002", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "27", "27.0", "", "", "87.3", "79.5", "", "58.0", "", "2", "", "", "201", "1", "1", "100", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.5", "93.0", "", "", "", "", "92.6"]} +{"pcdb_id": 9438, "brand_name": "Aquaflame", "model_name": "Eco-Avance II 30", "model_qualifier": "", "winter_efficiency_pct": 87.3, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 31.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009438", "000039", "0", "2012/Mar/27 10:12", "Aquaflame", "Aquaflame", "Eco-Avance II 30", "", "", "2002", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "31.3", "31.3", "", "", "87.3", "79.5", "", "58.0", "", "2", "", "", "201", "1", "1", "100", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.5", "93.0", "", "", "", "", "92.6"]} +{"pcdb_id": 9439, "brand_name": "Aquaflame", "model_name": "Eco-Avance II 38", "model_qualifier": "", "winter_efficiency_pct": 87.1, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 37.8, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009439", "000039", "0", "2012/Mar/27 10:12", "Aquaflame", "Aquaflame", "Eco-Avance II 38", "", "", "2002", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "37.8", "37.8", "", "", "87.1", "79.3", "", "57.9", "", "2", "", "", "201", "1", "1", "130", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.0", "92.9", "", "", "", "", "92.3"]} +{"pcdb_id": 9441, "brand_name": "Vokera", "model_name": "Hydra", "model_qualifier": "Hydra 26", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 56.1, "output_kw_max": 26.8, "final_year_of_manufacture": 2010, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009441", "000011", "0", "2010/Oct/21 11:04", "Vokera", "Vokera", "Hydra", "Hydra 26", "4709436", "2002", "2010", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "26.8", "26.8", "", "", "88.4", "79.8", "", "56.1", "", "2", "", "", "104", "1", "2", "130", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.5", "97.7", "", "", "", "", "95.9"]} +{"pcdb_id": 9442, "brand_name": "Vokera", "model_name": "Pinnacle", "model_qualifier": "Pinnacle 16", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 16.8, "final_year_of_manufacture": 2010, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009442", "000011", "0", "2012/Mar/27 10:12", "Vokera", "Vokera", "Pinnacle", "Pinnacle 16", "4109423", "2002", "2010", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "16.8", "16.8", "", "", "88.2", "79.2", "", "57.8", "", "2", "", "", "102", "1", "2", "130", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "97.3", "", "", "", "", "95.5"]} +{"pcdb_id": 9443, "brand_name": "Vokera", "model_name": "Pinnacle", "model_qualifier": "Pinnacle 26", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 26.8, "final_year_of_manufacture": 2010, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009443", "000011", "0", "2012/Mar/27 10:12", "Vokera", "Vokera", "Pinnacle", "Pinnacle 26", "4109424", "2002", "2010", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "26.8", "26.8", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.5", "97.7", "", "", "", "", "95.9"]} +{"pcdb_id": 9446, "brand_name": "Firebird", "model_name": "Rhino", "model_qualifier": "200-250 Boilerhouse", "winter_efficiency_pct": 86.2, "summer_efficiency_pct": 74.5, "comparative_hot_water_efficiency_pct": 54.4, "output_kw_max": null, "final_year_of_manufacture": 2013, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009446", "000223", "0", "2018/Jan/08 09:55", "Firebird Boilers", "Firebird", "Rhino", "200-250 Boilerhouse", "", "", "2013", "4", "1", "1", "1", "0", "", "", "1", "2", "1", "58.61", ">70kW", "", "", "86.2", "74.5", "", "54.4", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.5", "86.9", "", "", "", "", "86.6"]} +{"pcdb_id": 9447, "brand_name": "Firebird", "model_name": "Rhino", "model_qualifier": "200-250 Kitchen", "winter_efficiency_pct": 86.2, "summer_efficiency_pct": 74.5, "comparative_hot_water_efficiency_pct": 54.4, "output_kw_max": null, "final_year_of_manufacture": 2013, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009447", "000223", "0", "2018/Jan/08 09:54", "Firebird Boilers", "Firebird", "Rhino", "200-250 Kitchen", "", "", "2013", "4", "1", "1", "1", "0", "", "", "1", "2", "1", "58.61", ">70kW", "", "", "86.2", "74.5", "", "54.4", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.5", "86.9", "", "", "", "", "86.6"]} +{"pcdb_id": 9448, "brand_name": "Firebird", "model_name": "Rhino", "model_qualifier": "150-200 Boilerhouse", "winter_efficiency_pct": 86.4, "summer_efficiency_pct": 74.7, "comparative_hot_water_efficiency_pct": 54.6, "output_kw_max": 58.61, "final_year_of_manufacture": 2013, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009448", "000223", "0", "2018/Jan/08 10:09", "Firebird Boilers", "Firebird", "Rhino", "150-200 Boilerhouse", "", "", "2013", "4", "1", "1", "1", "0", "", "", "1", "2", "1", "43.96", "58.61", "", "", "86.4", "74.7", "", "54.6", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.1", "86.7", "", "", "", "", "86.6"]} +{"pcdb_id": 9449, "brand_name": "Firebird", "model_name": "Rhino", "model_qualifier": "150-200 Kitchen", "winter_efficiency_pct": 86.4, "summer_efficiency_pct": 74.7, "comparative_hot_water_efficiency_pct": 54.6, "output_kw_max": 58.61, "final_year_of_manufacture": 2013, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009449", "000223", "0", "2018/Jan/08 10:08", "Firebird Boilers", "Firebird", "Rhino", "150-200 Kitchen", "", "", "2013", "4", "1", "1", "1", "0", "", "", "1", "2", "1", "43.96", "58.61", "", "", "86.4", "74.7", "", "54.6", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.1", "86.7", "", "", "", "", "86.6"]} +{"pcdb_id": 9450, "brand_name": "Firebird", "model_name": "Rhino", "model_qualifier": "120-150 Boilerhouse", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 43.96, "final_year_of_manufacture": 2013, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009450", "000223", "0", "2018/Jan/08 10:13", "Firebird Boilers", "Firebird", "Rhino", "120-150 Boilerhouse", "", "", "2013", "4", "1", "1", "1", "0", "", "", "1", "2", "1", "36.63", "43.96", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.3", "87.2", "", "", "", "", "87.1"]} +{"pcdb_id": 9451, "brand_name": "Firebird", "model_name": "Rhino", "model_qualifier": "120-150 Kitchen", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 43.96, "final_year_of_manufacture": 2013, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009451", "000223", "0", "2018/Jan/08 10:13", "Firebird Boilers", "Firebird", "Rhino", "120-150 Kitchen", "", "", "2013", "4", "1", "1", "1", "0", "", "", "1", "2", "1", "36.63", "43.96", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.3", "87.2", "", "", "", "", "87.1"]} +{"pcdb_id": 9452, "brand_name": "Firebird", "model_name": "Rhino", "model_qualifier": "90-120 Boilerhouse", "winter_efficiency_pct": 86.4, "summer_efficiency_pct": 74.7, "comparative_hot_water_efficiency_pct": 54.6, "output_kw_max": 35.17, "final_year_of_manufacture": 2013, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009452", "000223", "0", "2018/Jan/08 10:07", "Firebird Boilers", "Firebird", "Rhino", "90-120 Boilerhouse", "", "", "2013", "4", "1", "1", "1", "0", "", "", "1", "2", "1", "26.38", "35.17", "", "", "86.4", "74.7", "", "54.6", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.4", "86.7", "", "", "", "", "86.6"]} +{"pcdb_id": 9453, "brand_name": "Firebird", "model_name": "Rhino", "model_qualifier": "90-120 Kitchen", "winter_efficiency_pct": 86.4, "summer_efficiency_pct": 74.7, "comparative_hot_water_efficiency_pct": 54.6, "output_kw_max": 35.17, "final_year_of_manufacture": 2013, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009453", "000223", "0", "2018/Jan/08 10:06", "Firebird Boilers", "Firebird", "Rhino", "90-120 Kitchen", "", "", "2013", "4", "1", "1", "1", "0", "", "", "1", "2", "1", "26.38", "35.17", "", "", "86.4", "74.7", "", "54.6", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.4", "86.7", "", "", "", "", "86.6"]} +{"pcdb_id": 9454, "brand_name": "Firebird", "model_name": "Rhino", "model_qualifier": "50-90 Boilerhouse", "winter_efficiency_pct": 86.1, "summer_efficiency_pct": 74.4, "comparative_hot_water_efficiency_pct": 54.4, "output_kw_max": 26.38, "final_year_of_manufacture": 2013, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009454", "000223", "0", "2018/Jan/08 09:53", "Firebird Boilers", "Firebird", "Rhino", "50-90 Boilerhouse", "", "", "2013", "4", "1", "2", "1", "0", "", "", "1", "1", "1", "14.65", "26.38", "", "", "86.1", "74.4", "", "54.4", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.8", "86.4", "", "", "", "", "86.3"]} +{"pcdb_id": 9455, "brand_name": "Firebird", "model_name": "Rhino", "model_qualifier": "50-90 Kitchen", "winter_efficiency_pct": 86.1, "summer_efficiency_pct": 74.4, "comparative_hot_water_efficiency_pct": 54.4, "output_kw_max": 26.38, "final_year_of_manufacture": 2013, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009455", "000223", "0", "2018/Jan/08 09:52", "Firebird Boilers", "Firebird", "Rhino", "50-90 Kitchen", "", "", "2013", "4", "1", "2", "1", "0", "", "", "1", "1", "1", "14.65", "26.38", "", "", "86.1", "74.4", "", "54.4", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.8", "86.4", "", "", "", "", "86.3"]} +{"pcdb_id": 9456, "brand_name": "Firebird", "model_name": "Rhino Heatpac", "model_qualifier": "90-120", "winter_efficiency_pct": 86.4, "summer_efficiency_pct": 74.7, "comparative_hot_water_efficiency_pct": 54.6, "output_kw_max": 35.17, "final_year_of_manufacture": 2013, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009456", "000223", "0", "2018/Jan/08 09:50", "Firebird Boilers", "Firebird", "Rhino Heatpac", "90-120", "", "", "2013", "4", "1", "1", "1", "0", "", "", "1", "2", "1", "26.38", "35.17", "", "", "86.4", "74.7", "", "54.6", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.4", "86.7", "", "", "", "", "86.6"]} +{"pcdb_id": 9457, "brand_name": "Firebird", "model_name": "Rhino Heatpac", "model_qualifier": "50-90", "winter_efficiency_pct": 86.1, "summer_efficiency_pct": 74.4, "comparative_hot_water_efficiency_pct": 54.4, "output_kw_max": 26.38, "final_year_of_manufacture": 2013, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009457", "000223", "0", "2018/Jan/08 09:46", "Firebird Boilers", "Firebird", "Rhino Heatpac", "50-90", "", "", "2013", "4", "1", "2", "1", "0", "", "", "1", "1", "1", "14.65", "26.38", "", "", "86.1", "74.4", "", "54.4", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.8", "86.4", "", "", "", "", "86.3"]} +{"pcdb_id": 9458, "brand_name": "Firebird", "model_name": "Rhino Slimline Heatpac", "model_qualifier": "50/90", "winter_efficiency_pct": 86.1, "summer_efficiency_pct": 74.4, "comparative_hot_water_efficiency_pct": 54.4, "output_kw_max": 26.38, "final_year_of_manufacture": 2013, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009458", "000223", "0", "2018/Jan/08 09:48", "Firebird Boilers", "Firebird", "Rhino Slimline Heatpac", "50/90", "", "", "2013", "4", "1", "2", "1", "0", "", "", "1", "1", "1", "14.65", "26.38", "", "", "86.1", "74.4", "", "54.4", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.8", "86.4", "", "", "", "", "86.3"]} +{"pcdb_id": 9460, "brand_name": "Vaillant", "model_name": "Turbomax Plus", "model_qualifier": "837 E", "winter_efficiency_pct": 80.7, "summer_efficiency_pct": 70.6, "comparative_hot_water_efficiency_pct": 49.6, "output_kw_max": 28.0, "final_year_of_manufacture": 2010, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009460", "000031", "0", "2010/Jan/28 08:41", "Vaillant", "Vaillant", "Turbomax Plus", "837 E", "VUW GB 362/2 - 5", "2002", "2010", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "28.0", "28.0", "", "", "80.7", "70.6", "", "49.6", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.0", "81.8", "", "", "", "", "81.8"]} +{"pcdb_id": 9461, "brand_name": "Vaillant", "model_name": "Ecomax", "model_qualifier": "pro 28 E", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 28.2, "final_year_of_manufacture": 2010, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009461", "000031", "0", "2012/Mar/27 10:12", "Vaillant", "Vaillant", "Ecomax", "pro 28 E", "VU GB 286 - 0", "2002", "2010", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "28.2", "28.2", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.7", "96.4", "", "", "", "", "95.0"]} +{"pcdb_id": 9462, "brand_name": "Vaillant", "model_name": "Ecomax", "model_qualifier": "pro 18 E", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 78.9, "comparative_hot_water_efficiency_pct": 57.6, "output_kw_max": 18.3, "final_year_of_manufacture": 2010, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009462", "000031", "0", "2012/Mar/27 10:12", "Vaillant", "Vaillant", "Ecomax", "pro 18 E", "VU GB 186 - 0", "2002", "2010", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18.3", "18.3", "", "", "87.9", "78.9", "", "57.6", "", "2", "", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.6", "96.3", "", "", "", "", "94.8"]} +{"pcdb_id": 9463, "brand_name": "Saunier Duval", "model_name": "Thema Classic F30E SB", "model_qualifier": "", "winter_efficiency_pct": 80.7, "summer_efficiency_pct": 70.0, "comparative_hot_water_efficiency_pct": 51.1, "output_kw_max": 29.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009463", "000206", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Saunier Duval", "Thema Classic F30E SB", "", "GC 41-920-45", "2002", "current", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "29.6", "29.6", "", "", "80.7", "70.0", "", "51.1", "", "2", "", "", "102", "1", "2", "122", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.2", "81.3", "", "", "", "", "81.4"]} +{"pcdb_id": 9464, "brand_name": "Saunier Duval", "model_name": "Saunier Duval F30E", "model_qualifier": "", "winter_efficiency_pct": 80.5, "summer_efficiency_pct": 70.4, "comparative_hot_water_efficiency_pct": 49.5, "output_kw_max": 29.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009464", "000206", "0", "2006/Jan/17 12:31", "Hepworth Heating", "Saunier Duval", "Saunier Duval F30E", "", "GC 41-920-45", "2002", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "29.6", "29.6", "", "", "80.5", "70.4", "", "49.5", "", "2", "", "", "104", "1", "2", "122", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "0", "0004", "", "", "", "", "", "", "", "", "82.2", "81.3", "", "", "", "", "81.4"]} +{"pcdb_id": 9465, "brand_name": "Glow-worm", "model_name": "30 si", "model_qualifier": "", "winter_efficiency_pct": 80.7, "summer_efficiency_pct": 70.0, "comparative_hot_water_efficiency_pct": 51.1, "output_kw_max": 29.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009465", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "30 si", "", "GC 41-920-45", "2002", "current", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "29.6", "29.6", "", "", "80.7", "70.0", "", "51.1", "", "2", "", "", "102", "1", "2", "122", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.2", "81.3", "", "", "", "", "81.4"]} +{"pcdb_id": 9466, "brand_name": "Glow-worm", "model_name": "30 ci", "model_qualifier": "", "winter_efficiency_pct": 80.5, "summer_efficiency_pct": 70.4, "comparative_hot_water_efficiency_pct": 49.5, "output_kw_max": 29.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009466", "000207", "0", "2012/Feb/20 11:07", "Hepworth Heating", "Glow-worm", "30 ci", "", "GC 41-920-45", "2002", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "29.6", "29.6", "", "", "80.5", "70.4", "", "49.5", "", "2", "", "", "104", "1", "2", "122", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "0", "0004", "", "", "", "", "", "", "", "", "82.2", "81.3", "", "", "", "", "81.4"]} +{"pcdb_id": 9467, "brand_name": "Halstead", "model_name": "Eden sb", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 27.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009467", "000019", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Halstead", "Eden sb", "", "76/BN/726", "2002", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "27.0", "27.0", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.7", "96.4", "", "", "", "", "95.0"]} +{"pcdb_id": 9468, "brand_name": "Halstead", "model_name": "Eden cb", "model_qualifier": "", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 55.8, "output_kw_max": 27.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009468", "000019", "0", "2006/Jun/20 11:47", "Hepworth Heating", "Halstead", "Eden cb", "", "76/BN/729", "2002", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "27.0", "27.0", "", "", "87.9", "79.3", "", "55.8", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.6", "96.3", "", "", "", "", "94.8"]} +{"pcdb_id": 9469, "brand_name": "Halstead", "model_name": "Eden vb", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 27.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009469", "000019", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Halstead", "Eden vb", "", "76/BN/726", "2002", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "27.0", "27.0", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.7", "96.4", "", "", "", "", "95.0"]} +{"pcdb_id": 9473, "brand_name": "Ideal", "model_name": "Buccaneer", "model_qualifier": "GTE6/OIL", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 39.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009473", "000008", "0", "2012/Mar/27 10:12", "DeDietrich", "Ideal", "Buccaneer", "GTE6/OIL", "", "2002", "current", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "32", "39", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.5", "87.8", "", "", "", "", "87.5"]} +{"pcdb_id": 9474, "brand_name": "Ideal", "model_name": "Buccaneer", "model_qualifier": "GTE5/OIL", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 33.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009474", "000008", "0", "2012/Mar/27 10:12", "DeDietrich", "Ideal", "Buccaneer", "GTE5/OIL", "", "2002", "current", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "27", "33", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.4", "88.5", "", "", "", "", "88.1"]} +{"pcdb_id": 9475, "brand_name": "Ideal", "model_name": "Buccaneer", "model_qualifier": "GTE4/OIL", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 27.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009475", "000008", "0", "2012/Mar/27 10:12", "DeDietrich", "Ideal", "Buccaneer", "GTE4/OIL", "", "2002", "current", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "21", "27", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.6", "89.5", "", "", "", "", "88.9"]} +{"pcdb_id": 9476, "brand_name": "Vokera", "model_name": "Mynute", "model_qualifier": "28e", "winter_efficiency_pct": 81.7, "summer_efficiency_pct": 71.0, "comparative_hot_water_efficiency_pct": 51.8, "output_kw_max": 28.0, "final_year_of_manufacture": 2010, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009476", "000011", "0", "2012/Mar/27 10:12", "Vokera", "Vokera", "Mynute", "28e", "4109418", "2002", "2010", "2", "2", "1", "1", "0", "", "", "1", "2", "2", "28", "28", "", "", "81.7", "71.0", "", "51.8", "", "2", "0", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "84.5", "80.9", "", "", "", "", "81.5"]} +{"pcdb_id": 9492, "brand_name": "Ariston", "model_name": "Ecocombi 27 MFFI", "model_qualifier": "microCONDENS Series", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 56.6, "output_kw_max": 27.0, "final_year_of_manufacture": 2007, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009492", "000080", "0", "2008/Sep/29 16:04", "Merloni TermoSanitari SpA", "Ariston", "Ecocombi 27 MFFI", "microCONDENS Series", "GC No. 47-116-17", "2002", "2007", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "27", "27", "", "", "89.1", "80.5", "", "56.6", "", "2", "1", "", "104", "1", "2", "130", "7", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.6", "98.8", "", "", "", "", "97.3"]} +{"pcdb_id": 9493, "brand_name": "Ariston", "model_name": "Ecosystem 27 RFFI", "model_qualifier": "microCONDENS Series", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 27.0, "final_year_of_manufacture": 2007, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009493", "000080", "0", "2012/Mar/27 10:12", "Merloni TermoSanitari SpA", "Ariston", "Ecosystem 27 RFFI", "microCONDENS Series", "GC No. 41-116-08", "2002", "2007", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "27", "27", "", "", "88.1", "79.1", "", "57.8", "", "2", "", "", "102", "1", "2", "130", "7", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.7", "96.7", "", "", "", "", "95.2"]} +{"pcdb_id": 9494, "brand_name": "Ariston", "model_name": "Ecocombi 27 MFFI", "model_qualifier": "microCONDENS Series", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 55.9, "output_kw_max": 27.0, "final_year_of_manufacture": 2007, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009494", "000080", "0", "2007/Jun/18 09:22", "Merloni TermoSanitari SpA", "Ariston", "Ecocombi 27 MFFI", "microCONDENS Series", "GC No. 47-116-17", "2002", "2007", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "27", "27", "", "", "88.1", "79.5", "", "55.9", "", "2", "", "", "104", "1", "2", "130", "7", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.7", "96.7", "", "", "", "", "95.2"]} +{"pcdb_id": 9495, "brand_name": "Halstead", "model_name": "Hero 30", "model_qualifier": "", "winter_efficiency_pct": 80.1, "summer_efficiency_pct": 70.0, "comparative_hot_water_efficiency_pct": 51.1, "output_kw_max": 8.79, "final_year_of_manufacture": 2006, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009495", "000019", "0", "2012/Mar/27 10:12", "Halstead Boilers", "Halstead", "Hero 30", "", "HR 30", "2002", "2006", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "8.79", "8.79", "", "", "80.1", "70.0", "", "51.1", "", "2", "", "", "101", "1", "1", "70", "5", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.5", "81.8", "", "", "", "", "81.8"]} +{"pcdb_id": 9496, "brand_name": "Halstead", "model_name": "Hero 40", "model_qualifier": "", "winter_efficiency_pct": 79.5, "summer_efficiency_pct": 69.4, "comparative_hot_water_efficiency_pct": 50.7, "output_kw_max": 11.72, "final_year_of_manufacture": 2006, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009496", "000019", "0", "2012/Mar/27 10:12", "Halstead Boilers", "Halstead", "Hero 40", "", "HR 40", "2002", "2006", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "11.72", "11.72", "", "", "79.5", "69.4", "", "50.7", "", "2", "", "", "101", "1", "1", "70", "5", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.4", "80.9", "", "", "", "", "81.0"]} +{"pcdb_id": 9497, "brand_name": "Halstead", "model_name": "Hero 40", "model_qualifier": "", "winter_efficiency_pct": 81.3, "summer_efficiency_pct": 71.2, "comparative_hot_water_efficiency_pct": 52.0, "output_kw_max": 11.72, "final_year_of_manufacture": 2006, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009497", "000019", "0", "2012/Mar/27 10:12", "Halstead Boilers", "Halstead", "Hero 40", "", "HRP 40", "2002", "2006", "2", "2", "1", "1", "0", "", "", "1", "2", "2", "11.72", "11.72", "", "", "81.3", "71.2", "", "52.0", "", "2", "1", "", "101", "1", "1", "70", "5", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "83.2", "82.7", "", "", "", "", "82.8"]} +{"pcdb_id": 9498, "brand_name": "Halstead", "model_name": "Hero 50", "model_qualifier": "", "winter_efficiency_pct": 79.4, "summer_efficiency_pct": 69.3, "comparative_hot_water_efficiency_pct": 50.6, "output_kw_max": 14.65, "final_year_of_manufacture": 2006, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009498", "000019", "0", "2012/Mar/27 10:12", "Halstead Boilers", "Halstead", "Hero 50", "", "HR 50", "2002", "2006", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "14.65", "14.65", "", "", "79.4", "69.3", "", "50.6", "", "2", "", "", "101", "1", "1", "70", "5", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "80.9", "81.0", "", "", "", "", "81.0"]} +{"pcdb_id": 9499, "brand_name": "Halstead", "model_name": "Hero 60", "model_qualifier": "", "winter_efficiency_pct": 80.0, "summer_efficiency_pct": 69.9, "comparative_hot_water_efficiency_pct": 51.1, "output_kw_max": 17.58, "final_year_of_manufacture": 2006, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009499", "000019", "0", "2012/Mar/27 10:12", "Halstead Boilers", "Halstead", "Hero 60", "", "HR 60", "2002", "2006", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "17.58", "17.58", "", "", "80.0", "69.9", "", "51.1", "", "2", "", "", "101", "1", "1", "70", "5", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.3", "82.0", "", "", "", "", "81.9"]} +{"pcdb_id": 9500, "brand_name": "Halstead", "model_name": "Hero 60", "model_qualifier": "", "winter_efficiency_pct": 81.8, "summer_efficiency_pct": 71.7, "comparative_hot_water_efficiency_pct": 52.4, "output_kw_max": 17.58, "final_year_of_manufacture": 2006, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009500", "000019", "0", "2012/Mar/27 10:12", "Halstead Boilers", "Halstead", "Hero 60", "", "HRP 60", "2002", "2006", "2", "2", "1", "1", "0", "", "", "1", "2", "2", "17.58", "17.58", "", "", "81.8", "71.7", "", "52.4", "", "2", "1", "", "101", "1", "1", "70", "5", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "83.1", "83.8", "", "", "", "", "83.7"]} +{"pcdb_id": 9501, "brand_name": "Halstead", "model_name": "Hero 75", "model_qualifier": "", "winter_efficiency_pct": 79.3, "summer_efficiency_pct": 69.2, "comparative_hot_water_efficiency_pct": 50.6, "output_kw_max": 22.0, "final_year_of_manufacture": 2006, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009501", "000019", "0", "2012/Mar/27 10:12", "Halstead Boilers", "Halstead", "Hero 75", "", "HR 75", "2002", "2006", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "22", "22.0", "", "", "79.3", "69.2", "", "50.6", "", "2", "", "", "101", "1", "1", "85", "5", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "80.9", "80.9", "", "", "", "", "80.9"]} +{"pcdb_id": 9502, "brand_name": "Halstead", "model_name": "Hero 90", "model_qualifier": "", "winter_efficiency_pct": 79.5, "summer_efficiency_pct": 69.4, "comparative_hot_water_efficiency_pct": 50.7, "output_kw_max": 26.37, "final_year_of_manufacture": 2006, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009502", "000019", "0", "2012/Mar/27 10:12", "Halstead Boilers", "Halstead", "Hero 90", "", "HR 90", "2002", "2006", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "26.37", "26.37", "", "", "79.5", "69.4", "", "50.7", "", "2", "", "", "101", "1", "1", "85", "5", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.1", "81.1", "", "", "", "", "81.1"]} +{"pcdb_id": 9503, "brand_name": "Saunier Duval", "model_name": "Thema Classic F30E Plus", "model_qualifier": "", "winter_efficiency_pct": 80.5, "summer_efficiency_pct": 70.4, "comparative_hot_water_efficiency_pct": 55.0, "output_kw_max": 29.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009503", "000206", "0", "2006/Jan/17 12:31", "Hepworth Heating", "Saunier Duval", "Thema Classic F30E Plus", "", "GC 47-920-38", "2002", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "29.6", "29.6", "", "", "80.5", "70.4", "", "55.0", "", "2", "", "", "104", "1", "2", "122", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "3", "1", "30", "0004", "", "", "", "", "", "", "", "", "82.2", "81.3", "", "", "", "", "81.4"]} +{"pcdb_id": 9504, "brand_name": "Saunier Duval", "model_name": "Thema Classic F24E Plus", "model_qualifier": "", "winter_efficiency_pct": 79.2, "summer_efficiency_pct": 69.1, "comparative_hot_water_efficiency_pct": 54.0, "output_kw_max": 23.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009504", "000206", "0", "2006/Jan/17 12:31", "Hepworth Heating", "Saunier Duval", "Thema Classic F24E Plus", "", "GC 47-920-37", "2001", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "23.6", "23.6", "", "", "79.2", "69.1", "", "54.0", "", "2", "", "", "104", "1", "2", "122", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "3", "1", "30", "0004", "", "", "", "", "", "", "", "", "81.4", "79.5", "", "", "", "", "79.8"]} +{"pcdb_id": 9505, "brand_name": "Glow-worm", "model_name": "30ci Plus", "model_qualifier": "", "winter_efficiency_pct": 80.5, "summer_efficiency_pct": 70.4, "comparative_hot_water_efficiency_pct": 55.0, "output_kw_max": 29.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009505", "000207", "0", "2006/Jan/17 12:31", "Hepworth Heating", "Glow-worm", "30ci Plus", "", "GC 47-047-22", "2002", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "29.6", "29.6", "", "", "80.5", "70.4", "", "55.0", "", "2", "", "", "104", "1", "2", "122", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "3", "1", "30", "0004", "", "", "", "", "", "", "", "", "82.2", "81.3", "", "", "", "", "81.4"]} +{"pcdb_id": 9506, "brand_name": "Glow-worm", "model_name": "24ci Plus", "model_qualifier": "", "winter_efficiency_pct": 79.2, "summer_efficiency_pct": 69.1, "comparative_hot_water_efficiency_pct": 54.0, "output_kw_max": 23.6, "final_year_of_manufacture": 2003, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009506", "000207", "0", "2006/Jan/17 12:55", "Hepworth Heating", "Glow-worm", "24ci Plus", "", "GC 47-047-21", "2001", "2003", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "23.6", "23.6", "", "", "79.2", "69.1", "", "54.0", "", "2", "", "", "104", "1", "2", "122", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "3", "1", "30", "0004", "", "", "", "", "", "", "", "", "81.4", "79.5", "", "", "", "", "79.8"]} +{"pcdb_id": 9507, "brand_name": "Potterton", "model_name": "Performa System", "model_qualifier": "12e", "winter_efficiency_pct": 79.9, "summer_efficiency_pct": 69.2, "comparative_hot_water_efficiency_pct": 50.6, "output_kw_max": 12.4, "final_year_of_manufacture": 2006, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009507", "000005", "0", "2012/Mar/27 10:12", "Baxi Potterton", "Potterton", "Performa System", "12e", "GC No. 41-590-88", "2002", "2006", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "12.4", "12.4", "", "", "79.9", "69.2", "", "50.6", "", "2", "", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.1", "79.7", "", "", "", "", "80.2"]} +{"pcdb_id": 9508, "brand_name": "Potterton", "model_name": "Performa System", "model_qualifier": "18e", "winter_efficiency_pct": 79.8, "summer_efficiency_pct": 69.1, "comparative_hot_water_efficiency_pct": 50.5, "output_kw_max": 17.5, "final_year_of_manufacture": 2006, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009508", "000005", "0", "2012/Mar/27 10:12", "Baxi Potterton", "Potterton", "Performa System", "18e", "GC No. 41-590-89", "2002", "2006", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "17.5", "17.5", "", "", "79.8", "69.1", "", "50.5", "", "2", "", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.1", "79.6", "", "", "", "", "80.0"]} +{"pcdb_id": 9509, "brand_name": "Potterton", "model_name": "Performa System", "model_qualifier": "24e", "winter_efficiency_pct": 79.7, "summer_efficiency_pct": 69.0, "comparative_hot_water_efficiency_pct": 50.4, "output_kw_max": 24.0, "final_year_of_manufacture": 2006, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009509", "000005", "0", "2012/Mar/27 10:12", "Baxi Potterton", "Potterton", "Performa System", "24e", "GC No. 41-590-90", "2002", "2006", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "24", "24", "", "", "79.7", "69.0", "", "50.4", "", "2", "", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.2", "79.2", "", "", "", "", "79.8"]} +{"pcdb_id": 9510, "brand_name": "Potterton", "model_name": "Performa System", "model_qualifier": "28e", "winter_efficiency_pct": 79.2, "summer_efficiency_pct": 68.5, "comparative_hot_water_efficiency_pct": 50.1, "output_kw_max": 29.4, "final_year_of_manufacture": 2005, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009510", "000005", "0", "2012/Mar/27 10:12", "Baxi Potterton", "Potterton", "Performa System", "28e", "GC No. 41-590-91", "2002", "2005", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "29.4", "29.4", "", "", "79.2", "68.5", "", "50.1", "", "2", "", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.2", "79.3", "", "", "", "", "79.6"]} +{"pcdb_id": 9511, "brand_name": "Potterton", "model_name": "Performa System", "model_qualifier": "12e", "winter_efficiency_pct": 81.9, "summer_efficiency_pct": 71.2, "comparative_hot_water_efficiency_pct": 52.0, "output_kw_max": 12.4, "final_year_of_manufacture": 2006, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009511", "000005", "0", "2012/Mar/27 10:12", "Baxi Potterton", "Potterton", "Performa System", "12e", "GC No. 41-590-88", "2002", "2006", "2", "2", "1", "1", "0", "", "", "1", "2", "2", "12.4", "12.4", "", "", "81.9", "71.2", "", "52.0", "", "2", "0", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "84.2", "81.7", "", "", "", "", "82.2"]} +{"pcdb_id": 9512, "brand_name": "Potterton", "model_name": "Performa System", "model_qualifier": "18e", "winter_efficiency_pct": 81.8, "summer_efficiency_pct": 71.1, "comparative_hot_water_efficiency_pct": 52.0, "output_kw_max": 17.5, "final_year_of_manufacture": 2006, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009512", "000005", "0", "2012/Mar/27 10:12", "Baxi Potterton", "Potterton", "Performa System", "18e", "GC No. 41-590-89", "2002", "2006", "2", "2", "1", "1", "0", "", "", "1", "2", "2", "17.5", "17.5", "", "", "81.8", "71.1", "", "52.0", "", "2", "0", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "84.2", "81.5", "", "", "", "", "82.0"]} +{"pcdb_id": 9513, "brand_name": "Potterton", "model_name": "Performa System", "model_qualifier": "24e", "winter_efficiency_pct": 81.8, "summer_efficiency_pct": 71.1, "comparative_hot_water_efficiency_pct": 51.9, "output_kw_max": 24.0, "final_year_of_manufacture": 2006, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009513", "000005", "0", "2012/Mar/27 10:12", "Baxi Potterton", "Potterton", "Performa System", "24e", "GC No. 41-590-90", "2002", "2006", "2", "2", "1", "1", "0", "", "", "1", "2", "2", "24", "24", "", "", "81.8", "71.1", "", "51.9", "", "2", "0", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "84.3", "81.3", "", "", "", "", "81.9"]} +{"pcdb_id": 9514, "brand_name": "Potterton", "model_name": "Performa System", "model_qualifier": "28e", "winter_efficiency_pct": 81.4, "summer_efficiency_pct": 70.7, "comparative_hot_water_efficiency_pct": 51.7, "output_kw_max": 29.4, "final_year_of_manufacture": 2005, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009514", "000005", "0", "2012/Mar/27 10:12", "Baxi Potterton", "Potterton", "Performa System", "28e", "GC No. 41-590-91", "2002", "2005", "2", "2", "1", "1", "0", "", "", "1", "2", "2", "29.4", "29.4", "", "", "81.4", "70.7", "", "51.7", "", "2", "0", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "83.4", "81.4", "", "", "", "", "81.8"]} +{"pcdb_id": 9515, "brand_name": "Clyde", "model_name": "GB112-43", "model_qualifier": "", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 78.9, "comparative_hot_water_efficiency_pct": 57.6, "output_kw_max": 42.9, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009515", "000012", "0", "2012/Mar/27 10:12", "Clyde Combustions", "Clyde", "GB112-43", "", "", "2002", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "42.9", "42.9", "", "", "87.9", "78.9", "", "57.6", "", "2", "", "", "102", "1", "2", "180", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.1", "96.4", "", "", "", "", "94.8"]} +{"pcdb_id": 9516, "brand_name": "Clyde", "model_name": "GB112-60", "model_qualifier": "", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 78.9, "comparative_hot_water_efficiency_pct": 57.6, "output_kw_max": 55.1, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009516", "000012", "0", "2012/Mar/27 10:12", "Clyde Combustions", "Clyde", "GB112-60", "", "", "2002", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "55.1", "55.1", "", "", "87.9", "78.9", "", "57.6", "", "2", "", "", "102", "1", "2", "200", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "96.5", "", "", "", "", "94.9"]} +{"pcdb_id": 9517, "brand_name": "Geminox", "model_name": "FCX", "model_qualifier": "", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 78.9, "comparative_hot_water_efficiency_pct": 57.6, "output_kw_max": 23.9, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009517", "000212", "0", "2012/Mar/27 10:12", "Geminox SA", "Geminox", "FCX", "", "", "1998", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "19.2", "23.9", "", "", "86.7", "78.9", "", "57.6", "", "2", "", "", "201", "1", "1", "210", "15", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "89.3", "92.2", "", "", "", "", "91.6"]} +{"pcdb_id": 9519, "brand_name": "Sime", "model_name": "Format System 24", "model_qualifier": "", "winter_efficiency_pct": 80.1, "summer_efficiency_pct": 69.4, "comparative_hot_water_efficiency_pct": 50.7, "output_kw_max": 23.4, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009519", "000213", "0", "2018/Feb/28 16:57", "Fonderie Sime S.p.A.", "Sime", "Format System 24", "", "", "2002", "2018", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "23.4", "23.4", "", "", "80.1", "69.4", "", "50.7", "", "2", "", "", "102", "1", "2", "150", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.7", "80.5", "", "", "", "", "80.8"]} +{"pcdb_id": 9520, "brand_name": "Sime", "model_name": "Format System 30", "model_qualifier": "", "winter_efficiency_pct": 80.3, "summer_efficiency_pct": 69.6, "comparative_hot_water_efficiency_pct": 50.8, "output_kw_max": 28.8, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009520", "000213", "0", "2018/Feb/28 17:02", "Fonderie Sime S.p.A.", "Sime", "Format System 30", "", "", "2002", "2018", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "28.8", "28.8", "", "", "80.3", "69.6", "", "50.8", "", "2", "", "", "102", "1", "2", "160", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.0", "80.5", "", "", "", "", "80.8"]} +{"pcdb_id": 9521, "brand_name": "Sime", "model_name": "Format System 24 EI", "model_qualifier": "", "winter_efficiency_pct": 80.1, "summer_efficiency_pct": 69.4, "comparative_hot_water_efficiency_pct": 50.7, "output_kw_max": 23.4, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009521", "000213", "0", "2018/Feb/28 16:58", "Fonderie Sime S.p.A.", "Sime", "Format System 24 EI", "", "", "2002", "2018", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "23.4", "23.4", "", "", "80.1", "69.4", "", "50.7", "", "2", "", "", "102", "1", "2", "150", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.7", "80.5", "", "", "", "", "80.8"]} +{"pcdb_id": 9522, "brand_name": "Sime", "model_name": "Format System 30 EI", "model_qualifier": "", "winter_efficiency_pct": 80.3, "summer_efficiency_pct": 69.6, "comparative_hot_water_efficiency_pct": 50.8, "output_kw_max": 28.8, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009522", "000213", "0", "2018/Mar/05 14:00", "Fonderie Sime S.p.A.", "Sime", "Format System 30 EI", "", "", "2002", "2018", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "28.8", "28.8", "", "", "80.3", "69.6", "", "50.8", "", "2", "", "", "102", "1", "2", "160", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.0", "80.5", "", "", "", "", "80.8"]} +{"pcdb_id": 9523, "brand_name": "Sime", "model_name": "Format System 24", "model_qualifier": "", "winter_efficiency_pct": 81.9, "summer_efficiency_pct": 71.2, "comparative_hot_water_efficiency_pct": 52.0, "output_kw_max": 23.4, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009523", "000213", "0", "2018/Feb/28 16:57", "Fonderie Sime S.p.A.", "Sime", "Format System 24", "", "LPG", "2002", "2018", "2", "2", "1", "1", "0", "", "", "1", "2", "2", "23.4", "23.4", "", "", "81.9", "71.2", "", "52.0", "", "2", "1", "", "102", "1", "2", "150", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "83.5", "82.3", "", "", "", "", "82.6"]} +{"pcdb_id": 9524, "brand_name": "Sime", "model_name": "Format System 30", "model_qualifier": "", "winter_efficiency_pct": 82.1, "summer_efficiency_pct": 71.4, "comparative_hot_water_efficiency_pct": 52.1, "output_kw_max": 28.8, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009524", "000213", "0", "2018/Mar/05 14:00", "Fonderie Sime S.p.A.", "Sime", "Format System 30", "", "LPG", "2002", "2018", "2", "2", "1", "1", "0", "", "", "1", "2", "2", "28.8", "28.8", "", "", "82.1", "71.4", "", "52.1", "", "2", "1", "", "102", "1", "2", "160", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "83.8", "82.3", "", "", "", "", "82.6"]} +{"pcdb_id": 9525, "brand_name": "Sime", "model_name": "Format System 24 EI", "model_qualifier": "", "winter_efficiency_pct": 81.9, "summer_efficiency_pct": 71.2, "comparative_hot_water_efficiency_pct": 52.0, "output_kw_max": 23.4, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009525", "000213", "0", "2018/Feb/28 16:58", "Fonderie Sime S.p.A.", "Sime", "Format System 24 EI", "", "LPG", "2002", "2018", "2", "2", "1", "1", "0", "", "", "1", "2", "2", "23.4", "23.4", "", "", "81.9", "71.2", "", "52.0", "", "2", "1", "", "102", "1", "2", "150", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "83.5", "82.3", "", "", "", "", "82.6"]} +{"pcdb_id": 9526, "brand_name": "Sime", "model_name": "Format System 30 EI", "model_qualifier": "", "winter_efficiency_pct": 82.1, "summer_efficiency_pct": 71.4, "comparative_hot_water_efficiency_pct": 52.1, "output_kw_max": 28.8, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009526", "000213", "0", "2018/Mar/05 14:01", "Fonderie Sime S.p.A.", "Sime", "Format System 30 EI", "", "LPG", "2002", "2018", "2", "2", "1", "1", "0", "", "", "1", "2", "2", "28.8", "28.8", "", "", "82.1", "71.4", "", "52.1", "", "2", "1", "", "102", "1", "2", "160", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "83.8", "82.3", "", "", "", "", "82.6"]} +{"pcdb_id": 9527, "brand_name": "Broag Remeha", "model_name": "Quinta", "model_qualifier": "Quinta 30", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 28.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009527", "000006", "0", "2012/Mar/27 10:12", "Remeha", "Broag Remeha", "Quinta", "Quinta 30", "0063BM3043", "2000", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "28", "28", "", "", "88.5", "79.5", "", "58.1", "", "2", "", "", "102", "1", "2", "46", "10", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "98.0", "", "", "", "", "96.2"]} +{"pcdb_id": 9529, "brand_name": "Broag Remeha", "model_name": "Quinta", "model_qualifier": "Quinta 30", "winter_efficiency_pct": 89.5, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 58.8, "output_kw_max": 28.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009529", "000006", "0", "2012/Mar/27 10:12", "Remeha", "Broag Remeha", "Quinta", "Quinta 30", "0063BM3043", "2000", "current", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "28", "28", "", "", "89.5", "80.5", "", "58.8", "", "2", "1", "", "102", "1", "2", "46", "10", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.3", "100.2", "", "", "", "", "98.3"]} +{"pcdb_id": 9531, "brand_name": "Chaffoteaux et Maury", "model_name": "Centora Green System 30", "model_qualifier": "", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 78.9, "comparative_hot_water_efficiency_pct": 57.6, "output_kw_max": 30.0, "final_year_of_manufacture": 2007, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009531", "000010", "0", "2012/Mar/27 10:12", "Chaffoteaux et Maury", "Chaffoteaux et Maury", "Centora Green System 30", "", "CG No. 41-980-31", "2002", "2007", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "30", "30", "", "", "87.9", "78.9", "", "57.6", "", "2", "", "", "102", "1", "2", "150", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "96.4", "", "", "", "", "94.8"]} +{"pcdb_id": 9532, "brand_name": "Chaffoteaux et Maury", "model_name": "Centora Green 30", "model_qualifier": "", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 55.7, "output_kw_max": 30.0, "final_year_of_manufacture": 2007, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009532", "000010", "0", "2007/Jun/18 09:14", "Chaffoteaux et Maury", "Chaffoteaux et Maury", "Centora Green 30", "", "GC No. 47-980-24", "2002", "2007", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "30", "30", "", "", "87.9", "79.3", "", "55.7", "", "2", "", "", "104", "1", "2", "150", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "96.4", "", "", "", "", "94.8"]} +{"pcdb_id": 9533, "brand_name": "Chaffoteaux et Maury", "model_name": "Calydra Green 30", "model_qualifier": "", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 55.7, "output_kw_max": 30.0, "final_year_of_manufacture": 2007, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009533", "000010", "0", "2007/Jun/18 09:14", "Chaffoteaux et Maury", "Chaffoteaux et Maury", "Calydra Green 30", "", "GC No. 47-980-26", "2002", "2007", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "30", "30", "", "", "87.9", "79.3", "", "55.7", "", "2", "", "", "104", "1", "2", "150", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "96.4", "", "", "", "", "94.8"]} +{"pcdb_id": 9534, "brand_name": "Sile SpA", "model_name": "Turbinox 21 N", "model_qualifier": "", "winter_efficiency_pct": 81.6, "summer_efficiency_pct": 70.9, "comparative_hot_water_efficiency_pct": 51.8, "output_kw_max": 23.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009534", "000221", "0", "2012/Mar/27 10:12", "Sile SpA", "Sile SpA", "Turbinox 21 N", "", "", "2002", "current", "2", "2", "1", "1", "0", "", "", "1", "2", "2", "23.50", "23.50", "", "", "81.6", "70.9", "", "51.8", "", "2", "0", "", "102", "1", "2", "140", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "84.0", "81.2", "", "", "", "", "81.8"]} +{"pcdb_id": 9535, "brand_name": "Sile SpA", "model_name": "Turbinox 25 N", "model_qualifier": "", "winter_efficiency_pct": 82.3, "summer_efficiency_pct": 71.6, "comparative_hot_water_efficiency_pct": 52.3, "output_kw_max": 26.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009535", "000221", "0", "2012/Mar/27 10:12", "Sile SpA", "Sile SpA", "Turbinox 25 N", "", "", "2002", "current", "2", "2", "1", "1", "0", "", "", "1", "2", "2", "26.50", "26.50", "", "", "82.3", "71.6", "", "52.3", "", "2", "0", "", "102", "1", "2", "140", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "84.7", "81.9", "", "", "", "", "82.4"]} +{"pcdb_id": 9536, "brand_name": "Sile SpA", "model_name": "Turbinox 25 BI", "model_qualifier": "", "winter_efficiency_pct": 82.4, "summer_efficiency_pct": 73.3, "comparative_hot_water_efficiency_pct": 33.0, "output_kw_max": 26.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009536", "000221", "0", "2024/Jan/31 10:17", "Sile SpA", "Sile SpA", "Turbinox 25 BI", "", "", "2002", "current", "2", "2", "1", "2", "0", "", "", "1", "2", "2", "26.50", "26.50", "", "", "82.4", "73.3", "", "33.0", "", "2", "0", "", "106", "1", "2", "140", "0", "2", "", "0", "60", "0", "10", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "84.7", "81.9", "", "", "", "", "82.4"]} +{"pcdb_id": 9537, "brand_name": "Sile SpA", "model_name": "Turbinox 21 BI", "model_qualifier": "", "winter_efficiency_pct": 81.7, "summer_efficiency_pct": 72.6, "comparative_hot_water_efficiency_pct": 33.9, "output_kw_max": 23.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009537", "000221", "0", "2024/Jan/31 10:17", "Sile SpA", "Sile SpA", "Turbinox 21 BI", "", "", "2002", "current", "2", "2", "1", "2", "0", "", "", "1", "2", "2", "23.5", "23.5", "", "", "81.7", "72.6", "", "33.9", "", "2", "0", "", "106", "1", "2", "140", "0", "2", "", "0", "50", "0", "10", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "84.0", "81.2", "", "", "", "", "81.8"]} +{"pcdb_id": 9538, "brand_name": "Sile SpA", "model_name": "Turbinox 21 N", "model_qualifier": "", "winter_efficiency_pct": 80.4, "summer_efficiency_pct": 69.7, "comparative_hot_water_efficiency_pct": 50.9, "output_kw_max": 23.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009538", "000221", "0", "2012/Mar/27 10:12", "Sile SpA", "Sile SpA", "Turbinox 21 N", "", "", "2002", "current", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "23.50", "23.50", "", "", "80.4", "69.7", "", "50.9", "", "2", "", "", "102", "1", "2", "140", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "83.0", "79.9", "", "", "", "", "80.5"]} +{"pcdb_id": 9539, "brand_name": "Sile SpA", "model_name": "Turbinox 25 N", "model_qualifier": "", "winter_efficiency_pct": 80.9, "summer_efficiency_pct": 70.2, "comparative_hot_water_efficiency_pct": 51.2, "output_kw_max": 26.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009539", "000221", "0", "2012/Mar/27 10:12", "Sile SpA", "Sile SpA", "Turbinox 25 N", "", "", "2002", "current", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "26.50", "26.50", "", "", "80.9", "70.2", "", "51.2", "", "2", "", "", "102", "1", "2", "140", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "83.5", "80.8", "", "", "", "", "81.3"]} +{"pcdb_id": 9540, "brand_name": "Sile SpA", "model_name": "Turbinox 25 BI", "model_qualifier": "", "winter_efficiency_pct": 81.0, "summer_efficiency_pct": 71.9, "comparative_hot_water_efficiency_pct": 32.3, "output_kw_max": 26.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009540", "000221", "0", "2024/Jan/31 10:17", "Sile SpA", "Sile SpA", "Turbinox 25 BI", "", "", "2002", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "26.50", "26.50", "", "", "81.0", "71.9", "", "32.3", "", "2", "", "", "106", "1", "2", "140", "0", "2", "", "0", "60", "0", "10", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "83.5", "80.8", "", "", "", "", "81.3"]} +{"pcdb_id": 9541, "brand_name": "Sile SpA", "model_name": "Turbinox 21 BI", "model_qualifier": "", "winter_efficiency_pct": 80.5, "summer_efficiency_pct": 71.4, "comparative_hot_water_efficiency_pct": 33.3, "output_kw_max": 23.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009541", "000221", "0", "2024/Jan/31 10:17", "Sile SpA", "Sile SpA", "Turbinox 21 BI", "", "", "2002", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "23.50", "23.50", "", "", "80.5", "71.4", "", "33.3", "", "2", "", "", "106", "1", "2", "140", "0", "2", "", "0", "50", "0", "10", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "83.0", "79.9", "", "", "", "", "80.5"]} +{"pcdb_id": 9542, "brand_name": "Vokera", "model_name": "Mynute", "model_qualifier": "Mynute 16e LPG", "winter_efficiency_pct": 82.1, "summer_efficiency_pct": 72.0, "comparative_hot_water_efficiency_pct": 52.6, "output_kw_max": 16.0, "final_year_of_manufacture": 2010, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009542", "000011", "0", "2012/Mar/27 10:12", "Vokera", "Vokera", "Mynute", "Mynute 16e LPG", "4109422", "2002", "2010", "2", "2", "1", "1", "0", "", "", "1", "2", "2", "12", "16.0", "", "", "82.1", "72.0", "", "52.6", "", "2", "0", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "84.5", "82.8", "", "", "", "", "83.1"]} +{"pcdb_id": 9543, "brand_name": "Vokera", "model_name": "Mynute", "model_qualifier": "Mynute 12e LPG", "winter_efficiency_pct": 82.3, "summer_efficiency_pct": 72.2, "comparative_hot_water_efficiency_pct": 52.8, "output_kw_max": 12.0, "final_year_of_manufacture": 2010, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009543", "000011", "0", "2012/Mar/27 10:12", "Vokera", "Vokera", "Mynute", "Mynute 12e LPG", "4109421", "2002", "2010", "2", "2", "1", "1", "0", "", "", "1", "2", "2", "7.4", "12.0", "", "", "82.3", "72.2", "", "52.8", "", "2", "0", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.5", "83.2", "", "", "", "", "83.6"]} +{"pcdb_id": 9544, "brand_name": "Vokera", "model_name": "Pinnacle", "model_qualifier": "Pinnacle 26 LPG", "winter_efficiency_pct": 90.4, "summer_efficiency_pct": 81.4, "comparative_hot_water_efficiency_pct": 59.5, "output_kw_max": 26.8, "final_year_of_manufacture": 2010, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009544", "000011", "0", "2012/Mar/27 10:12", "Vokera", "Vokera", "Pinnacle", "Pinnacle 26 LPG", "4109424", "2002", "2010", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "26.8", "26.8", "", "", "90.4", "81.4", "", "59.5", "", "2", "0", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.9", "100.0", "", "", "", "", "98.1"]} +{"pcdb_id": 9545, "brand_name": "Vokera", "model_name": "Hydra", "model_qualifier": "Hydra 26 LPG", "winter_efficiency_pct": 90.4, "summer_efficiency_pct": 81.8, "comparative_hot_water_efficiency_pct": 57.5, "output_kw_max": 26.8, "final_year_of_manufacture": 2010, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009545", "000011", "0", "2010/Oct/21 11:05", "Vokera", "Vokera", "Hydra", "Hydra 26 LPG", "4709436", "2002", "2010", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "26.8", "26.8", "", "", "90.4", "81.8", "", "57.5", "", "2", "0", "", "104", "1", "2", "130", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.9", "100.0", "", "", "", "", "98.1"]} +{"pcdb_id": 9546, "brand_name": "Vokera", "model_name": "Pinnacle", "model_qualifier": "Pinnacle 16 LPG", "winter_efficiency_pct": 90.1, "summer_efficiency_pct": 81.1, "comparative_hot_water_efficiency_pct": 59.3, "output_kw_max": 16.8, "final_year_of_manufacture": 2010, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009546", "000011", "0", "2012/Mar/27 10:12", "Vokera", "Vokera", "Pinnacle", "Pinnacle 16 LPG", "4109423", "2002", "2010", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "16.8", "16.8", "", "", "90.1", "81.1", "", "59.3", "", "2", "0", "", "102", "1", "2", "130", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.3", "99.5", "", "", "", "", "97.5"]} +{"pcdb_id": 9547, "brand_name": "A J Wells and Sons", "model_name": "Charnwood OLX45 Hearth Boiler", "model_qualifier": "", "winter_efficiency_pct": 83.7, "summer_efficiency_pct": 72.0, "comparative_hot_water_efficiency_pct": 52.6, "output_kw_max": 13.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009547", "000224", "0", "2019/Jul/16 16:10", "A J Wells and Sons", "A J Wells and Sons", "Charnwood OLX45 Hearth Boiler", "", "", "2000", "current", "4", "4", "1", "1", "0", "", "", "1", "1", "2", "11", "13.4", "", "", "83.7", "72.0", "", "52.6", "", "2", "", "", "201", "1", "1", "200", "60", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "84.1", "83.3", "", "", "", "", "83.5"]} +{"pcdb_id": 9548, "brand_name": "Vokera", "model_name": "Compact", "model_qualifier": "24", "winter_efficiency_pct": 81.4, "summer_efficiency_pct": 71.3, "comparative_hot_water_efficiency_pct": 50.1, "output_kw_max": 24.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009548", "000011", "0", "2006/Jan/17 12:31", "Vokera", "Vokera", "Compact", "24", "", "2002", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "24.0", "24.0", "", "", "81.4", "71.3", "", "50.1", "", "2", "", "", "104", "1", "2", "125", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "83.3", "82.3", "", "", "", "", "82.4"]} +{"pcdb_id": 9549, "brand_name": "Vokera", "model_name": "Compact", "model_qualifier": "28", "winter_efficiency_pct": 81.3, "summer_efficiency_pct": 71.2, "comparative_hot_water_efficiency_pct": 50.1, "output_kw_max": 28.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009549", "000011", "0", "2006/Jan/17 12:31", "Vokera", "Vokera", "Compact", "28", "", "2002", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "28.0", "28.0", "", "", "81.3", "71.2", "", "50.1", "", "2", "", "", "104", "1", "2", "125", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "83.3", "82.2", "", "", "", "", "82.4"]} +{"pcdb_id": 9550, "brand_name": "Vokera", "model_name": "Compact", "model_qualifier": "24 LPG", "winter_efficiency_pct": 83.1, "summer_efficiency_pct": 73.0, "comparative_hot_water_efficiency_pct": 51.3, "output_kw_max": 24.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009550", "000011", "0", "2006/Jan/17 12:31", "Vokera", "Vokera", "Compact", "24 LPG", "", "2002", "current", "2", "2", "1", "2", "0", "", "", "1", "2", "2", "24.0", "24.0", "", "", "83.1", "73.0", "", "51.3", "", "2", "0", "", "104", "1", "2", "125", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "84.9", "83.8", "", "", "", "", "84.0"]} +{"pcdb_id": 9551, "brand_name": "Vokera", "model_name": "Compact", "model_qualifier": "28 LPG", "winter_efficiency_pct": 82.7, "summer_efficiency_pct": 72.6, "comparative_hot_water_efficiency_pct": 51.1, "output_kw_max": 28.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009551", "000011", "0", "2006/Jan/17 12:31", "Vokera", "Vokera", "Compact", "28 LPG", "", "2002", "current", "2", "2", "1", "2", "0", "", "", "1", "2", "2", "28.0", "28.0", "", "", "82.7", "72.6", "", "51.1", "", "2", "0", "", "104", "1", "2", "125", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "84.5", "83.4", "", "", "", "", "83.6"]} +{"pcdb_id": 9552, "brand_name": "Sime", "model_name": "Format 110 C", "model_qualifier": "", "winter_efficiency_pct": 79.3, "summer_efficiency_pct": 69.2, "comparative_hot_water_efficiency_pct": 48.7, "output_kw_max": 31.6, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009552", "000213", "0", "2018/Feb/26 17:00", "Fonderie Sime S.p.A.", "Sime", "Format 110 C", "", "", "2003", "2018", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "31.6", "31.6", "", "", "79.3", "69.2", "", "48.7", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.8", "79.3", "", "", "", "", "79.8"]} +{"pcdb_id": 9553, "brand_name": "Sime", "model_name": "Format 110 C LPG", "model_qualifier": "", "winter_efficiency_pct": 81.1, "summer_efficiency_pct": 71.0, "comparative_hot_water_efficiency_pct": 50.0, "output_kw_max": 31.6, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009553", "000213", "0", "2018/Feb/26 17:01", "Fonderie Sime S.p.A.", "Sime", "Format 110 C LPG", "", "", "2003", "2018", "2", "2", "1", "2", "0", "", "", "1", "2", "2", "31.6", "31.6", "", "", "81.1", "71.0", "", "50.0", "", "2", "1", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "83.6", "81.0", "", "", "", "", "81.5"]} +{"pcdb_id": 9554, "brand_name": "Ravenheat", "model_name": "Little Star LS 100", "model_qualifier": "", "winter_efficiency_pct": 80.5, "summer_efficiency_pct": 70.4, "comparative_hot_water_efficiency_pct": 49.5, "output_kw_max": 29.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009554", "000026", "0", "2006/Jan/17 12:31", "Ravenheat", "Ravenheat", "Little Star LS 100", "", "", "2003", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "29.0", "29.0", "", "", "80.5", "70.4", "", "49.5", "", "2", "", "", "104", "1", "2", "150", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "83.3", "80.5", "", "", "", "", "81.1"]} +{"pcdb_id": 9555, "brand_name": "Ravenheat", "model_name": "Little Star LS 100 T", "model_qualifier": "", "winter_efficiency_pct": 80.5, "summer_efficiency_pct": 70.4, "comparative_hot_water_efficiency_pct": 49.5, "output_kw_max": 29.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009555", "000026", "0", "2006/Jan/17 12:31", "Ravenheat", "Ravenheat", "Little Star LS 100 T", "", "", "2003", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "29.0", "29.0", "", "", "80.5", "70.4", "", "49.5", "", "2", "", "", "104", "1", "2", "150", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "83.3", "80.5", "", "", "", "", "81.1"]} +{"pcdb_id": 9556, "brand_name": "Ravenheat", "model_name": "Little Star LS 100", "model_qualifier": "", "winter_efficiency_pct": 82.3, "summer_efficiency_pct": 72.2, "comparative_hot_water_efficiency_pct": 50.8, "output_kw_max": 29.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009556", "000026", "0", "2006/Jan/17 12:31", "Ravenheat", "Ravenheat", "Little Star LS 100", "", "", "2003", "current", "2", "2", "1", "2", "0", "", "", "1", "2", "2", "29.0", "29.0", "", "", "82.3", "72.2", "", "50.8", "", "2", "0", "", "104", "1", "2", "150", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "85.1", "82.3", "", "", "", "", "82.9"]} +{"pcdb_id": 9557, "brand_name": "Ravenheat", "model_name": "Little Star LS 100 T", "model_qualifier": "", "winter_efficiency_pct": 82.3, "summer_efficiency_pct": 72.2, "comparative_hot_water_efficiency_pct": 50.8, "output_kw_max": 29.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009557", "000026", "0", "2006/Jan/17 12:31", "Ravenheat", "Ravenheat", "Little Star LS 100 T", "", "", "2003", "current", "2", "2", "1", "2", "0", "", "", "1", "2", "2", "29.0", "29.0", "", "", "82.3", "72.2", "", "50.8", "", "2", "0", "", "104", "1", "2", "150", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "85.1", "82.3", "", "", "", "", "82.9"]} +{"pcdb_id": 9558, "brand_name": "Boulter", "model_name": "Pathfinder", "model_qualifier": "C2/6A (Gas Oil)", "winter_efficiency_pct": 85.3, "summer_efficiency_pct": 73.6, "comparative_hot_water_efficiency_pct": 53.8, "output_kw_max": 37.2, "final_year_of_manufacture": 2005, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009558", "000041", "0", "2012/Mar/27 10:12", "Boulter Buderus", "Boulter", "Pathfinder", "C2/6A (Gas Oil)", "", "2003", "2005", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "37.2", "37.2", "", "", "85.3", "73.6", "", "53.8", "", "2", "", "", "201", "1", "1", "150", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "84.9", "85.7", "", "", "", "", "85.6"]} +{"pcdb_id": 9559, "brand_name": "Boulter", "model_name": "Pathfinder", "model_qualifier": "C2/7A (Gas Oil)", "winter_efficiency_pct": 85.4, "summer_efficiency_pct": 73.7, "comparative_hot_water_efficiency_pct": 53.8, "output_kw_max": 44.9, "final_year_of_manufacture": 2005, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009559", "000041", "0", "2012/Mar/27 10:12", "Boulter Buderus", "Boulter", "Pathfinder", "C2/7A (Gas Oil)", "", "2003", "2005", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "44.9", "44.9", "", "", "85.4", "73.7", "", "53.8", "", "2", "", "", "201", "1", "1", "150", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.0", "85.8", "", "", "", "", "85.7"]} +{"pcdb_id": 9560, "brand_name": "Boulter", "model_name": "Pathfinder", "model_qualifier": "C2/8A (Gas Oil)", "winter_efficiency_pct": 85.5, "summer_efficiency_pct": 73.8, "comparative_hot_water_efficiency_pct": 53.9, "output_kw_max": 52.7, "final_year_of_manufacture": 2005, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009560", "000041", "0", "2012/Mar/27 10:12", "Boulter Buderus", "Boulter", "Pathfinder", "C2/8A (Gas Oil)", "", "2003", "2005", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "52.7", "52.7", "", "", "85.5", "73.8", "", "53.9", "", "2", "", "", "201", "1", "1", "150", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.1", "85.8", "", "", "", "", "85.7"]} +{"pcdb_id": 9561, "brand_name": "Boulter", "model_name": "Pathfinder", "model_qualifier": "C2/9A (Gas Oil)", "winter_efficiency_pct": 85.7, "summer_efficiency_pct": 74.0, "comparative_hot_water_efficiency_pct": 54.1, "output_kw_max": 57.1, "final_year_of_manufacture": 2005, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009561", "000041", "0", "2012/Mar/27 10:12", "Boulter Buderus", "Boulter", "Pathfinder", "C2/9A (Gas Oil)", "", "2003", "2005", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "57.1", "57.1", "", "", "85.7", "74.0", "", "54.1", "", "2", "", "", "201", "1", "1", "150", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.3", "86.2", "", "", "", "", "86.0"]} +{"pcdb_id": 9562, "brand_name": "Boulter", "model_name": "Pathfinder", "model_qualifier": "C2/10A (Gas Oil)", "winter_efficiency_pct": 86.0, "summer_efficiency_pct": 74.3, "comparative_hot_water_efficiency_pct": 54.3, "output_kw_max": 62.2, "final_year_of_manufacture": 2005, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009562", "000041", "0", "2012/Mar/27 10:12", "Boulter Buderus", "Boulter", "Pathfinder", "C2/10A (Gas Oil)", "", "2003", "2005", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "62.2", "62.2", "", "", "86.0", "74.3", "", "54.3", "", "2", "", "", "201", "1", "1", "150", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.5", "86.5", "", "", "", "", "86.3"]} +{"pcdb_id": 9563, "brand_name": "Boulter", "model_name": "Pathfinder", "model_qualifier": "C2/6A (Kerosene)", "winter_efficiency_pct": 85.7, "summer_efficiency_pct": 74.0, "comparative_hot_water_efficiency_pct": 54.0, "output_kw_max": 37.4, "final_year_of_manufacture": 2005, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009563", "000041", "0", "2012/Mar/27 10:12", "Boulter Buderus", "Boulter", "Pathfinder", "C2/6A (Kerosene)", "", "2003", "2005", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "37.4", "37.4", "", "", "85.7", "74.0", "", "54.0", "", "2", "", "", "201", "1", "1", "150", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.5", "85.9", "", "", "", "", "85.8"]} +{"pcdb_id": 9564, "brand_name": "Boulter", "model_name": "Pathfinder", "model_qualifier": "C2/7A (Kerosene)", "winter_efficiency_pct": 85.6, "summer_efficiency_pct": 73.9, "comparative_hot_water_efficiency_pct": 54.0, "output_kw_max": 44.9, "final_year_of_manufacture": 2005, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009564", "000041", "0", "2012/Mar/27 10:12", "Boulter Buderus", "Boulter", "Pathfinder", "C2/7A (Kerosene)", "", "2003", "2005", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "44.9", "44.9", "", "", "85.6", "73.9", "", "54.0", "", "2", "", "", "201", "1", "1", "150", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.3", "85.9", "", "", "", "", "85.8"]} +{"pcdb_id": 9565, "brand_name": "Boulter", "model_name": "Pathfinder", "model_qualifier": "C2/8A (Kerosene)", "winter_efficiency_pct": 85.6, "summer_efficiency_pct": 73.9, "comparative_hot_water_efficiency_pct": 54.0, "output_kw_max": 52.7, "final_year_of_manufacture": 2005, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009565", "000041", "0", "2012/Mar/27 10:12", "Boulter Buderus", "Boulter", "Pathfinder", "C2/8A (Kerosene)", "", "2003", "2005", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "52.7", "52.7", "", "", "85.6", "73.9", "", "54.0", "", "2", "", "", "201", "1", "1", "150", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.3", "85.9", "", "", "", "", "85.8"]} +{"pcdb_id": 9566, "brand_name": "Boulter", "model_name": "Pathfinder", "model_qualifier": "C2/9A (Kerosene)", "winter_efficiency_pct": 85.7, "summer_efficiency_pct": 74.0, "comparative_hot_water_efficiency_pct": 54.0, "output_kw_max": 57.1, "final_year_of_manufacture": 2005, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009566", "000041", "0", "2012/Mar/27 10:12", "Boulter Buderus", "Boulter", "Pathfinder", "C2/9A (Kerosene)", "", "2003", "2005", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "57.1", "57.1", "", "", "85.7", "74.0", "", "54.0", "", "2", "", "", "201", "1", "1", "150", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.3", "86.1", "", "", "", "", "86.0"]} +{"pcdb_id": 9567, "brand_name": "Boulter", "model_name": "Pathfinder", "model_qualifier": "C2/10A (Kerosene)", "winter_efficiency_pct": 85.8, "summer_efficiency_pct": 74.1, "comparative_hot_water_efficiency_pct": 54.1, "output_kw_max": 62.2, "final_year_of_manufacture": 2005, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009567", "000041", "0", "2012/Mar/27 10:12", "Boulter Buderus", "Boulter", "Pathfinder", "C2/10A (Kerosene)", "", "2003", "2005", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "62.2", "62.2", "", "", "85.8", "74.1", "", "54.1", "", "2", "", "", "201", "1", "1", "150", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.3", "86.3", "", "", "", "", "86.1"]} +{"pcdb_id": 9568, "brand_name": "GAH Heating Products", "model_name": "Combistream", "model_qualifier": "BFC 40/60", "winter_efficiency_pct": 84.8, "summer_efficiency_pct": 76.7, "comparative_hot_water_efficiency_pct": 46.2, "output_kw_max": 18.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009568", "000051", "0", "2024/Jan/31 10:17", "GAH Heating Products", "GAH Heating Products", "Combistream", "BFC 40/60", "", "2003", "current", "4", "1", "1", "2", "0", "", "", "1", "2", "2", "11.7", "18.2", "", "", "84.8", "76.7", "", "46.2", "", "2", "", "", "203", "1", "1", "1200", "0", "2", "", "0", "60", "0", "25", "1", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "88.2", "88.3", "", "", "", "", "88.2"]} +{"pcdb_id": 9569, "brand_name": "Worcester", "model_name": "24i Junior", "model_qualifier": "", "winter_efficiency_pct": 78.9, "summer_efficiency_pct": 68.8, "comparative_hot_water_efficiency_pct": 48.4, "output_kw_max": 23.5, "final_year_of_manufacture": 2005, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009569", "000035", "0", "2020/Sep/04 08:05", "Worcester Heat Systems", "Worcester", "24i Junior", "", "GC no 47 311 69", "2003", "2005", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "23.5", "23.5", "", "", "78.9", "68.8", "", "48.4", "", "2", "", "", "104", "1", "2", "152", "8", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.6", "78.6", "", "", "", "", "79.1"]} +{"pcdb_id": 9570, "brand_name": "Worcester", "model_name": "24i Junior", "model_qualifier": "", "winter_efficiency_pct": 80.9, "summer_efficiency_pct": 70.8, "comparative_hot_water_efficiency_pct": 49.8, "output_kw_max": 23.5, "final_year_of_manufacture": 2005, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009570", "000035", "0", "2020/Sep/04 08:05", "Worcester Heat Systems", "Worcester", "24i Junior", "", "GC No 47 311 71", "2003", "2005", "2", "2", "1", "2", "0", "", "", "1", "2", "2", "23.5", "23.5", "", "", "80.9", "70.8", "", "49.8", "", "2", "0", "", "104", "1", "2", "150", "8", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "85.4", "79.5", "", "", "", "", "80.6"]} +{"pcdb_id": 9571, "brand_name": "Worcester", "model_name": "28i Junior", "model_qualifier": "", "winter_efficiency_pct": 79.8, "summer_efficiency_pct": 69.7, "comparative_hot_water_efficiency_pct": 49.0, "output_kw_max": 27.5, "final_year_of_manufacture": 2005, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009571", "000035", "0", "2020/Sep/04 08:05", "Worcester Heat Systems", "Worcester", "28i Junior", "", "GC No 47 311 70", "2003", "2005", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "27.5", "27.5", "", "", "79.8", "69.7", "", "49.0", "", "2", "", "", "104", "1", "2", "152", "8", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.3", "79.7", "", "", "", "", "80.2"]} +{"pcdb_id": 9572, "brand_name": "Worcester", "model_name": "28i Junior", "model_qualifier": "", "winter_efficiency_pct": 82.6, "summer_efficiency_pct": 72.5, "comparative_hot_water_efficiency_pct": 51.0, "output_kw_max": 27.5, "final_year_of_manufacture": 2005, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009572", "000035", "0", "2020/Sep/04 08:05", "Worcester Heat Systems", "Worcester", "28i Junior", "", "GC No 47 311 72", "2003", "2005", "2", "2", "1", "2", "0", "", "", "1", "2", "2", "27.5", "27.5", "", "", "82.6", "72.5", "", "51.0", "", "2", "0", "", "104", "1", "2", "152", "8", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "85.2", "82.9", "", "", "", "", "83.3"]} +{"pcdb_id": 9573, "brand_name": "Sime", "model_name": "Planet Dewy 90 A", "model_qualifier": "", "winter_efficiency_pct": 89.3, "summer_efficiency_pct": 80.7, "comparative_hot_water_efficiency_pct": 56.7, "output_kw_max": 24.5, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009573", "000213", "0", "2018/Mar/05 14:31", "Fonderie Sime S.p.A.", "Sime", "Planet Dewy 90 A", "", "", "2003", "2018", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.5", "24.5", "", "", "89.3", "80.7", "", "56.7", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.1", "100.0", "", "", "", "", "97.8"]} +{"pcdb_id": 9574, "brand_name": "Sime", "model_name": "Planet Dewy 90 A (LPG)", "model_qualifier": "", "winter_efficiency_pct": 90.3, "summer_efficiency_pct": 81.7, "comparative_hot_water_efficiency_pct": 57.5, "output_kw_max": 24.5, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009574", "000213", "0", "2018/Mar/05 14:31", "Fonderie Sime S.p.A.", "Sime", "Planet Dewy 90 A (LPG)", "", "", "2003", "2018", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24.5", "24.5", "", "", "90.3", "81.7", "", "57.5", "", "2", "1", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.1", "102.2", "", "", "", "", "99.9"]} +{"pcdb_id": 9575, "brand_name": "Sime", "model_name": "Planet Dewy 110 A", "model_qualifier": "", "winter_efficiency_pct": 89.3, "summer_efficiency_pct": 80.7, "comparative_hot_water_efficiency_pct": 56.8, "output_kw_max": 29.4, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009575", "000213", "0", "2018/Mar/05 14:28", "Fonderie Sime S.p.A.", "Sime", "Planet Dewy 110 A", "", "", "2003", "2018", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "29.4", "29.4", "", "", "89.3", "80.7", "", "56.8", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "100.0", "", "", "", "", "97.8"]} +{"pcdb_id": 9576, "brand_name": "Sime", "model_name": "Planet Dewy 110 A (LPG)", "model_qualifier": "", "winter_efficiency_pct": 90.3, "summer_efficiency_pct": 81.7, "comparative_hot_water_efficiency_pct": 57.5, "output_kw_max": 29.4, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009576", "000213", "0", "2018/Mar/05 14:28", "Fonderie Sime S.p.A.", "Sime", "Planet Dewy 110 A (LPG)", "", "", "2003", "2018", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "29.4", "29.4", "", "", "90.3", "81.7", "", "57.5", "", "2", "1", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.3", "102.2", "", "", "", "", "100.0"]} +{"pcdb_id": 9577, "brand_name": "Sime", "model_name": "Planet Dewy 110 T A", "model_qualifier": "", "winter_efficiency_pct": 89.3, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 58.7, "output_kw_max": 29.4, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009577", "000213", "0", "2018/Mar/05 14:29", "Fonderie Sime S.p.A.", "Sime", "Planet Dewy 110 T A", "", "", "2003", "2018", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "29.4", "29.4", "", "", "89.3", "80.3", "", "58.7", "", "2", "", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "100.0", "", "", "", "", "97.8"]} +{"pcdb_id": 9578, "brand_name": "Sime", "model_name": "Planet Dewy 110 T A (LPG)", "model_qualifier": "", "winter_efficiency_pct": 90.3, "summer_efficiency_pct": 81.3, "comparative_hot_water_efficiency_pct": 59.4, "output_kw_max": 29.4, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009578", "000213", "0", "2018/Mar/05 14:29", "Fonderie Sime S.p.A.", "Sime", "Planet Dewy 110 T A (LPG)", "", "", "2003", "2018", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "29.4", "29.4", "", "", "90.3", "81.3", "", "59.4", "", "2", "1", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.3", "102.2", "", "", "", "", "100.0"]} +{"pcdb_id": 9579, "brand_name": "Chaffoteaux et Maury", "model_name": "Centora Green System 24", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 24.0, "final_year_of_manufacture": 2007, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009579", "000010", "0", "2012/Mar/27 10:12", "Chaffoteaux et Maury", "Chaffoteaux et Maury", "Centora Green System 24", "", "GC No. 41-980-12", "2002", "2007", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24", "24", "", "", "88.3", "79.3", "", "57.9", "", "2", "", "", "102", "1", "2", "150", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.1", "97.5", "", "", "", "", "95.7"]} +{"pcdb_id": 9580, "brand_name": "Chaffoteaux et Maury", "model_name": "Centora Green 24", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 56.0, "output_kw_max": 24.0, "final_year_of_manufacture": 2007, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009580", "000010", "0", "2007/Jun/18 09:13", "Chaffoteaux et Maury", "Chaffoteaux et Maury", "Centora Green 24", "", "GC No. 47-980-21", "2002", "2007", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "88.3", "79.7", "", "56.0", "", "2", "", "", "104", "1", "2", "150", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.1", "97.5", "", "", "", "", "95.7"]} +{"pcdb_id": 9581, "brand_name": "Chaffoteaux et Maury", "model_name": "Calydra Green 24", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 56.0, "output_kw_max": 24.0, "final_year_of_manufacture": 2007, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009581", "000010", "0", "2007/Jun/18 09:13", "Chaffoteaux et Maury", "Chaffoteaux et Maury", "Calydra Green 24", "", "GC No. 47-980-25", "2002", "2007", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "88.3", "79.7", "", "56.0", "", "2", "", "", "104", "1", "2", "150", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.1", "97.5", "", "", "", "", "95.7"]} +{"pcdb_id": 9582, "brand_name": "Glow-worm", "model_name": "38cxi", "model_qualifier": "", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 55.8, "output_kw_max": 30.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009582", "000207", "0", "2006/Jan/17 12:31", "Hepworth Heating", "Glow-worm", "38cxi", "", "GC 47-047-27", "2002", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "30.0", "30.0", "", "", "87.9", "79.3", "", "55.8", "", "2", "", "", "104", "1", "2", "180", "15", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.7", "96.3", "", "", "", "", "94.9"]} +{"pcdb_id": 9583, "brand_name": "Boulter", "model_name": "Buderus", "model_qualifier": "600/11S", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 11.0, "final_year_of_manufacture": 2007, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009583", "000041", "0", "2012/Mar/27 10:12", "Boulter Buderus", "Boulter", "Buderus", "600/11S", "7105030", "2000", "2007", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "11.0", "11.0", "", "", "88.6", "79.6", "", "58.2", "", "2", "", "", "102", "1", "2", "115", "6.5", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.1", "98.3", "", "", "", "", "96.4"]} +{"pcdb_id": 9584, "brand_name": "Boulter", "model_name": "Buderus", "model_qualifier": "600/19S", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 19.0, "final_year_of_manufacture": 2007, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009584", "000041", "0", "2012/Mar/27 10:12", "Boulter Buderus", "Boulter", "Buderus", "600/19S", "7105040", "2000", "2007", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "19.0", "19.0", "", "", "88.6", "79.6", "", "58.1", "", "2", "", "", "102", "1", "2", "115", "6.5", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.1", "98.2", "", "", "", "", "96.3"]} +{"pcdb_id": 9585, "brand_name": "Boulter", "model_name": "Buderus", "model_qualifier": "600/24S", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 24.0, "final_year_of_manufacture": 2007, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009585", "000041", "0", "2012/Mar/27 10:12", "Boulter Buderus", "Boulter", "Buderus", "600/24S", "7105050", "2000", "2007", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24.0", "24.0", "", "", "88.5", "79.5", "", "58.1", "", "2", "", "", "102", "1", "2", "115", "6.5", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "98.0", "", "", "", "", "96.1"]} +{"pcdb_id": 9586, "brand_name": "Boulter", "model_name": "Buderus", "model_qualifier": "600/24C", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 56.2, "output_kw_max": 24.0, "final_year_of_manufacture": 2007, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009586", "000041", "0", "2008/Aug/18 09:29", "Boulter Buderus", "Boulter", "Buderus", "600/24C", "7105060", "2000", "2007", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.0", "24.0", "", "", "88.5", "79.9", "", "56.2", "", "2", "", "", "104", "1", "2", "115", "8", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "98.0", "", "", "", "", "96.1"]} +{"pcdb_id": 9587, "brand_name": "Boulter", "model_name": "Buderus", "model_qualifier": "800/24", "winter_efficiency_pct": 87.8, "summer_efficiency_pct": 78.8, "comparative_hot_water_efficiency_pct": 57.6, "output_kw_max": 23.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009587", "000041", "0", "2012/Mar/27 10:12", "Boulter Buderus", "Boulter", "Buderus", "800/24", "87470124", "1999", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "23.40", "23.40", "", "", "87.8", "78.8", "", "57.6", "", "2", "", "", "102", "1", "2", "120", "8", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.7", "96.4", "", "", "", "", "94.7"]} +{"pcdb_id": 9588, "brand_name": "Boulter", "model_name": "Buderus", "model_qualifier": "800-24T25/V", "winter_efficiency_pct": 87.8, "summer_efficiency_pct": 80.6, "comparative_hot_water_efficiency_pct": 50.6, "output_kw_max": 23.4, "final_year_of_manufacture": 2004, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009588", "000041", "0", "2024/Jan/31 10:17", "Boulter Buderus", "Boulter", "Buderus", "800-24T25/V", "87470128", "1999", "2004", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "23.40", "23.40", "", "", "87.8", "80.6", "", "50.6", "", "2", "", "", "106", "1", "2", "120", "8", "2", "2", "0", "26", "0", "27", "2", "60", "25", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.7", "96.4", "", "", "", "", "94.7"]} +{"pcdb_id": 9589, "brand_name": "Boulter", "model_name": "Buderus", "model_qualifier": "800-24T25/H", "winter_efficiency_pct": 87.8, "summer_efficiency_pct": 80.6, "comparative_hot_water_efficiency_pct": 50.6, "output_kw_max": 23.4, "final_year_of_manufacture": 2004, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009589", "000041", "0", "2024/Jan/31 10:17", "Boulter Buderus", "Boulter", "Buderus", "800-24T25/H", "87470132", "1999", "2004", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "23.4", "23.4", "", "", "87.8", "80.6", "", "50.6", "", "2", "", "", "106", "1", "2", "120", "8", "2", "2", "0", "26", "0", "27", "2", "60", "25", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.7", "96.4", "", "", "", "", "94.7"]} +{"pcdb_id": 9590, "brand_name": "Boulter", "model_name": "Buderus", "model_qualifier": "800/29", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 78.9, "comparative_hot_water_efficiency_pct": 57.6, "output_kw_max": 29.9, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009590", "000041", "0", "2012/Mar/27 10:12", "Boulter Buderus", "Boulter", "Buderus", "800/29", "87470126", "1999", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "29.9", "29.9", "", "", "87.9", "78.9", "", "57.6", "", "2", "", "", "102", "1", "2", "130", "8", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "96.5", "", "", "", "", "94.9"]} +{"pcdb_id": 9591, "brand_name": "Boulter", "model_name": "Buderus", "model_qualifier": "800-29T25/V", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 80.6, "comparative_hot_water_efficiency_pct": 50.7, "output_kw_max": 29.9, "final_year_of_manufacture": 2004, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009591", "000041", "0", "2024/Jan/31 10:17", "Boulter Buderus", "Boulter", "Buderus", "800-29T25/V", "87470130", "1999", "2004", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "29.90", "29.90", "", "", "87.9", "80.6", "", "50.7", "", "2", "", "", "106", "1", "2", "130", "8", "2", "2", "0", "26", "0", "27", "2", "60", "25", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "96.5", "", "", "", "", "94.9"]} +{"pcdb_id": 9592, "brand_name": "Boulter", "model_name": "Buderus", "model_qualifier": "800-29T25/H", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 80.6, "comparative_hot_water_efficiency_pct": 51.5, "output_kw_max": 29.9, "final_year_of_manufacture": 2004, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009592", "000041", "0", "2024/Jan/31 10:17", "Boulter Buderus", "Boulter", "Buderus", "800-29T25/H", "87470134", "1999", "2004", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "29.90", "29.90", "", "", "87.9", "80.6", "", "51.5", "", "2", "", "", "106", "1", "2", "130", "8", "2", "2", "0", "26", "0", "30", "2", "60", "25", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "96.5", "", "", "", "", "94.9"]} +{"pcdb_id": 9593, "brand_name": "Boulter", "model_name": "Buderus", "model_qualifier": "800/43", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 78.9, "comparative_hot_water_efficiency_pct": 57.6, "output_kw_max": 42.9, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009593", "000041", "0", "2012/Mar/27 10:12", "Boulter Buderus", "Boulter", "Buderus", "800/43", "87470110", "1999", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "42.9", "42.9", "", "", "87.9", "78.9", "", "57.6", "", "2", "", "", "102", "1", "2", "180", "8", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.1", "96.4", "", "", "", "", "94.8"]} +{"pcdb_id": 9594, "brand_name": "Boulter", "model_name": "Buderus", "model_qualifier": "800/60", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 78.9, "comparative_hot_water_efficiency_pct": 57.6, "output_kw_max": 60.0, "final_year_of_manufacture": 2008, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009594", "000041", "0", "2012/Mar/27 10:12", "Boulter Buderus", "Boulter", "Buderus", "800/60", "87470112", "1999", "2008", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "60", "60", "", "", "87.9", "78.9", "", "57.6", "", "2", "", "", "102", "1", "2", "200", "8", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "96.5", "", "", "", "", "94.9"]} +{"pcdb_id": 9595, "brand_name": "Itho Images bv", "model_name": "Ethos", "model_qualifier": "28", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 56.4, "output_kw_max": 28.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009595", "000226", "0", "2013/Jun/25 14:36", "Itho Images bv", "Itho Images bv", "Ethos", "28", "", "2003", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28", "28", "", "", "88.8", "80.2", "", "56.4", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "98.7", "", "", "", "", "96.8"]} +{"pcdb_id": 9596, "brand_name": "Itho Images bv", "model_name": "Ethos", "model_qualifier": "36", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 56.4, "output_kw_max": 36.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009596", "000226", "0", "2013/Jun/25 14:36", "Itho Images bv", "Itho Images bv", "Ethos", "36", "", "2003", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "36", "36", "", "", "88.8", "80.2", "", "56.4", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "98.7", "", "", "", "", "96.8"]} +{"pcdb_id": 9597, "brand_name": "Itho Images bv", "model_name": "Ethos", "model_qualifier": "46", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 56.4, "output_kw_max": 46.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009597", "000226", "0", "2013/Jun/25 14:36", "Itho Images bv", "Itho Images bv", "Ethos", "46", "", "2003", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "46", "46", "", "", "88.8", "80.2", "", "56.4", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "98.7", "", "", "", "", "96.8"]} +{"pcdb_id": 9598, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "ZWBR 7-30 HE Plus", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 55.9, "output_kw_max": 29.5, "final_year_of_manufacture": 2003, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009598", "000035", "0", "2003/Jun/17 12:54", "Worcester Heat Systems", "Worcester", "Greenstar", "ZWBR 7-30 HE Plus", "47 311 75", "2003", "2003", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "29.5", "29.5", "", "", "88.1", "79.5", "", "55.9", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.9", "96.8", "", "", "", "", "95.3"]} +{"pcdb_id": 9599, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "ZB 7-28 HE", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 27.7, "final_year_of_manufacture": 2003, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009599", "000035", "0", "2012/Mar/27 10:12", "Worcester Heat Systems", "Worcester", "Greenstar", "ZB 7-28 HE", "41 311 58", "2003", "2003", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "27.7", "27.7", "", "", "88.1", "79.1", "", "57.8", "", "2", "", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.9", "96.8", "", "", "", "", "95.3"]} +{"pcdb_id": 9600, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "ZWBR 11-35 HE Plus", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 56.5, "output_kw_max": 35.5, "final_year_of_manufacture": 2003, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009600", "000035", "0", "2003/Jun/17 12:56", "Worcester Heat Systems", "Worcester", "Greenstar", "ZWBR 11-35 HE Plus", "47 311 57", "2002", "2003", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "35.5", "35.5", "", "", "88.9", "80.3", "", "56.5", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.5", "98.9", "", "", "", "", "96.9"]} +{"pcdb_id": 9601, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "ZWB 7-25 HE Combi", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 55.9, "output_kw_max": 27.5, "final_year_of_manufacture": 2003, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009601", "000035", "0", "2003/Jun/17 12:52", "Worcester Heat Systems", "Worcester", "Greenstar", "ZWB 7-25 HE Combi", "47 311 73", "2003", "2003", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "27.5", "27.5", "", "", "88.1", "79.5", "", "55.9", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.9", "96.8", "", "", "", "", "95.3"]} +{"pcdb_id": 9602, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "ZWB 7-30 HE Combi", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 55.9, "output_kw_max": 29.5, "final_year_of_manufacture": 2003, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009602", "000035", "0", "2003/Jun/17 12:52", "Worcester Heat Systems", "Worcester", "Greenstar", "ZWB 7-30 HE Combi", "47 311 74", "2003", "2003", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "29.5", "29.5", "", "", "88.1", "79.5", "", "55.9", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.9", "96.8", "", "", "", "", "95.3"]} +{"pcdb_id": 9603, "brand_name": "Firebird", "model_name": "Combi", "model_qualifier": "50-70", "winter_efficiency_pct": 83.3, "summer_efficiency_pct": 75.2, "comparative_hot_water_efficiency_pct": 41.2, "output_kw_max": 20.52, "final_year_of_manufacture": 2013, "subsidiary_type": 0, "store_type": 1, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009603", "000047", "0", "2024/Jan/31 10:17", "Firebird Boilers", "Firebird", "Combi", "50-70", "", "2003", "2013", "4", "1", "1", "2", "0", "", "", "1", "2", "1", "14.65", "20.52", "", "", "83.3", "75.2", "", "41.2", "", "2", "", "", "203", "1", "1", "138", "0", "1", "1", "0", "40", "0", "25", "3", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.1", "85.4", "", "", "", "", "85.3"]} +{"pcdb_id": 9604, "brand_name": "Firebird", "model_name": "Combipac", "model_qualifier": "50-70", "winter_efficiency_pct": 83.3, "summer_efficiency_pct": 75.2, "comparative_hot_water_efficiency_pct": 41.2, "output_kw_max": 20.52, "final_year_of_manufacture": 2013, "subsidiary_type": 0, "store_type": 1, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009604", "000047", "0", "2024/Jan/31 10:17", "Firebird Boilers", "Firebird", "Combipac", "50-70", "", "2003", "2013", "4", "1", "2", "2", "0", "", "", "1", "1", "1", "14.65", "20.52", "", "", "83.3", "75.2", "", "41.2", "", "2", "", "", "203", "1", "1", "138", "0", "1", "1", "0", "40", "0", "25", "3", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.1", "85.4", "", "", "", "", "85.3"]} +{"pcdb_id": 9605, "brand_name": "Firebird", "model_name": "Combi", "model_qualifier": "70-90", "winter_efficiency_pct": 83.3, "summer_efficiency_pct": 75.2, "comparative_hot_water_efficiency_pct": 41.2, "output_kw_max": 26.38, "final_year_of_manufacture": 2010, "subsidiary_type": 0, "store_type": 1, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009605", "000047", "0", "2024/Jan/31 10:17", "Firebird Boilers", "Firebird", "Combi", "70-90", "", "2003", "2010", "4", "1", "1", "2", "0", "", "", "1", "2", "1", "20.52", "26.38", "", "", "83.3", "75.2", "", "41.2", "", "2", "", "", "203", "1", "1", "138", "0", "1", "1", "0", "40", "0", "25", "3", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "84.7", "85.7", "", "", "", "", "85.5"]} +{"pcdb_id": 9606, "brand_name": "Firebird", "model_name": "Combipac", "model_qualifier": "70-90", "winter_efficiency_pct": 83.3, "summer_efficiency_pct": 75.2, "comparative_hot_water_efficiency_pct": 41.2, "output_kw_max": 26.38, "final_year_of_manufacture": 2013, "subsidiary_type": 0, "store_type": 1, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009606", "000047", "0", "2024/Jan/31 10:17", "Firebird Boilers", "Firebird", "Combipac", "70-90", "", "2003", "2013", "4", "1", "2", "2", "0", "", "", "1", "1", "1", "20.52", "26.38", "", "", "83.3", "75.2", "", "41.2", "", "2", "", "", "203", "1", "1", "138", "0", "1", "1", "0", "40", "0", "25", "3", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "84.7", "85.7", "", "", "", "", "85.5"]} +{"pcdb_id": 9607, "brand_name": "Firebird", "model_name": "Combi", "model_qualifier": "90-120", "winter_efficiency_pct": 84.5, "summer_efficiency_pct": 76.4, "comparative_hot_water_efficiency_pct": 41.6, "output_kw_max": 35.17, "final_year_of_manufacture": 2013, "subsidiary_type": 0, "store_type": 1, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009607", "000047", "0", "2024/Jan/31 10:17", "Firebird Boilers", "Firebird", "Combi", "90-120", "", "2003", "2013", "4", "1", "1", "2", "0", "", "", "1", "2", "1", "26.38", "35.17", "", "", "84.5", "76.4", "", "41.6", "", "2", "", "", "203", "1", "1", "138", "0", "1", "1", "0", "44", "0", "25", "3", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.4", "86.7", "", "", "", "", "86.6"]} +{"pcdb_id": 9608, "brand_name": "Firebird", "model_name": "Combipac", "model_qualifier": "90-120", "winter_efficiency_pct": 84.5, "summer_efficiency_pct": 76.4, "comparative_hot_water_efficiency_pct": 41.6, "output_kw_max": 35.17, "final_year_of_manufacture": 2013, "subsidiary_type": 0, "store_type": 1, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009608", "000047", "0", "2024/Jan/31 10:17", "Firebird Boilers", "Firebird", "Combipac", "90-120", "", "2003", "2013", "4", "1", "2", "2", "0", "", "", "1", "1", "1", "26.38", "35.17", "", "", "84.5", "76.4", "", "41.6", "", "2", "", "", "203", "1", "1", "138", "0", "1", "1", "0", "44", "0", "25", "3", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.4", "86.7", "", "", "", "", "86.6"]} +{"pcdb_id": 9609, "brand_name": "Radiant", "model_name": "RK 25", "model_qualifier": "", "winter_efficiency_pct": 87.7, "summer_efficiency_pct": 78.7, "comparative_hot_water_efficiency_pct": 57.5, "output_kw_max": 26.67, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009609", "000088", "0", "2012/Mar/27 10:12", "Radiant Bruciatori SpA", "Radiant", "RK 25", "", "", "2002", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "26.67", "26.67", "", "", "87.7", "78.7", "", "57.5", "", "2", "", "", "102", "1", "2", "170", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.7", "95.8", "", "", "", "", "94.4"]} +{"pcdb_id": 9610, "brand_name": "Radiant", "model_name": "RKR 25", "model_qualifier": "", "winter_efficiency_pct": 87.7, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 55.6, "output_kw_max": 26.67, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009610", "000088", "0", "2006/Jan/17 12:31", "Radiant Bruciatori SpA", "Radiant", "RKR 25", "", "", "2002", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "26.67", "26.67", "", "", "87.7", "79.1", "", "55.6", "", "2", "", "", "104", "1", "2", "180", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.7", "95.8", "", "", "", "", "94.4"]} +{"pcdb_id": 9611, "brand_name": "Radiant", "model_name": "RKA 100", "model_qualifier": "", "winter_efficiency_pct": 87.7, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 36.6, "output_kw_max": 26.67, "final_year_of_manufacture": 2007, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009611", "000088", "0", "2024/Jan/31 10:17", "Radiant Bruciatori SpA", "Radiant", "RKA 100", "", "", "2002", "2007", "1", "1", "1", "2", "0", "", "", "2", "2", "2", "26.67", "26.67", "", "", "87.7", "81.0", "", "36.6", "", "2", "", "", "106", "1", "2", "180", "", "2", "2", "0", "104", "0", "15", "2", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.7", "95.8", "", "", "", "", "94.4"]} +{"pcdb_id": 9612, "brand_name": "Radiant", "model_name": "RKA 25", "model_qualifier": "", "winter_efficiency_pct": 87.7, "summer_efficiency_pct": 80.6, "comparative_hot_water_efficiency_pct": 44.8, "output_kw_max": 26.67, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009612", "000088", "0", "2024/Jan/31 10:17", "Radiant Bruciatori SpA", "Radiant", "RKA 25", "", "", "2002", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "26.67", "26.67", "", "", "87.7", "80.6", "", "44.8", "", "2", "", "", "106", "1", "2", "180", "", "2", "2", "0", "28.3", "0", "15", "2", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.7", "95.8", "", "", "", "", "94.4"]} +{"pcdb_id": 9613, "brand_name": "Radiant", "model_name": "RMAS 30 E", "model_qualifier": "", "winter_efficiency_pct": 81.5, "summer_efficiency_pct": 72.4, "comparative_hot_water_efficiency_pct": 40.3, "output_kw_max": 31.9, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009613", "000088", "0", "2024/Jan/31 10:17", "Radiant Bruciatori SpA", "Radiant", "RMAS 30 E", "", "", "2002", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "31.90", "31.90", "", "", "81.5", "72.4", "", "40.3", "", "2", "", "", "106", "1", "2", "170", "", "2", "2", "0", "28.3", "0", "15", "2", "60", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "83.3", "81.5", "", "", "", "", "81.9"]} +{"pcdb_id": 9614, "brand_name": "Radiant", "model_name": "RS 30 E", "model_qualifier": "", "winter_efficiency_pct": 81.2, "summer_efficiency_pct": 70.5, "comparative_hot_water_efficiency_pct": 51.5, "output_kw_max": 31.9, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009614", "000088", "0", "2012/Mar/27 10:12", "Radiant Bruciatori SpA", "Radiant", "RS 30 E", "", "", "2002", "current", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "31.90", "31.90", "", "", "81.2", "70.5", "", "51.5", "", "2", "", "", "102", "1", "2", "170", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "83.3", "81.5", "", "", "", "", "81.9"]} +{"pcdb_id": 9615, "brand_name": "Radiant", "model_name": "RSF 30 E", "model_qualifier": "", "winter_efficiency_pct": 81.0, "summer_efficiency_pct": 70.9, "comparative_hot_water_efficiency_pct": 49.9, "output_kw_max": 31.9, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009615", "000088", "0", "2006/Jan/17 12:31", "Radiant Bruciatori SpA", "Radiant", "RSF 30 E", "", "", "2002", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "31.90", "31.90", "", "", "81.0", "70.9", "", "49.9", "", "2", "", "", "104", "1", "2", "170", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "83.3", "81.5", "", "", "", "", "81.9"]} +{"pcdb_id": 9616, "brand_name": "ATAG", "model_name": "Blauwe Engel", "model_qualifier": "SHR 15", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 14.4, "final_year_of_manufacture": 2007, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009616", "000227", "0", "2012/Mar/27 10:12", "ATAG Verwarming Nederland BV", "ATAG", "Blauwe Engel", "SHR 15", "", "1996", "2007", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "14.4", "14.4", "", "", "88.6", "79.6", "", "58.2", "", "2", "", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.5", "98.2", "", "", "", "", "96.4"]} +{"pcdb_id": 9617, "brand_name": "ATAG", "model_name": "Blauwe Engel", "model_qualifier": "SHR 24", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 23.0, "final_year_of_manufacture": 2007, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009617", "000227", "0", "2012/Mar/27 10:12", "ATAG Verwarming Nederland BV", "ATAG", "Blauwe Engel", "SHR 24", "", "1996", "2007", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "23.0", "23.0", "", "", "88.6", "79.6", "", "58.2", "", "2", "", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.5", "98.2", "", "", "", "", "96.4"]} +{"pcdb_id": 9618, "brand_name": "ATAG", "model_name": "Premier", "model_qualifier": "E-SHR 35", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 33.6, "final_year_of_manufacture": 2007, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009618", "000227", "0", "2012/Mar/27 10:12", "ATAG Verwarming Nederland BV", "ATAG", "Premier", "E-SHR 35", "", "1999", "2007", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "33.6", "33.6", "", "", "88.3", "79.3", "", "57.9", "", "2", "", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.4", "97.3", "", "", "", "", "95.6"]} +{"pcdb_id": 9619, "brand_name": "ATAG", "model_name": "Blauwe Engel", "model_qualifier": "SHR 35", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 33.6, "final_year_of_manufacture": 2007, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009619", "000227", "0", "2012/Mar/27 10:12", "ATAG Verwarming Nederland BV", "ATAG", "Blauwe Engel", "SHR 35", "", "1996", "2007", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "33.6", "33.6", "", "", "88.3", "79.3", "", "57.9", "", "2", "", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.4", "97.3", "", "", "", "", "95.6"]} +{"pcdb_id": 9620, "brand_name": "ATAG", "model_name": "Blauwe Engel", "model_qualifier": "SHR 51", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 48.7, "final_year_of_manufacture": 2003, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009620", "000227", "0", "2012/Mar/27 10:12", "ATAG Verwarming Nederland BV", "ATAG", "Blauwe Engel", "SHR 51", "", "1996", "2003", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "48.7", "48.7", "", "", "88.5", "79.5", "", "58.0", "", "2", "", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.6", "98.1", "", "", "", "", "96.1"]} +{"pcdb_id": 9621, "brand_name": "ATAG", "model_name": "Blauwe Engel", "model_qualifier": "SHR 60", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 57.2, "final_year_of_manufacture": 2007, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009621", "000227", "0", "2012/Mar/27 10:12", "ATAG Verwarming Nederland BV", "ATAG", "Blauwe Engel", "SHR 60", "", "1996", "2007", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "57.2", "57.2", "", "", "88.3", "79.3", "", "57.9", "", "2", "", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.1", "97.5", "", "", "", "", "95.7"]} +{"pcdb_id": 9622, "brand_name": "ATAG", "model_name": "Premier", "model_qualifier": "E-SHR 24T", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 23.0, "final_year_of_manufacture": 2007, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009622", "000227", "0", "2012/Mar/27 10:12", "ATAG Verwarming Nederland BV", "ATAG", "Premier", "E-SHR 24T", "", "1999", "2007", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "23.0", "23.0", "", "", "88.6", "79.6", "", "58.2", "", "2", "", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.5", "98.2", "", "", "", "", "96.4"]} +{"pcdb_id": 9623, "brand_name": "ATAG", "model_name": "Premier", "model_qualifier": "E-SHR 35T", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 56.0, "output_kw_max": 33.6, "final_year_of_manufacture": 2007, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009623", "000227", "0", "2018/Apr/25 14:41", "ATAG Verwarming Nederland BV", "ATAG", "Premier", "E-SHR 35T", "", "1999", "2007", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "33.6", "33.6", "", "", "88.3", "79.7", "", "56.0", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.4", "97.3", "", "", "", "", "95.6"]} +{"pcdb_id": 9624, "brand_name": "ATAG", "model_name": "Blauwe Engel", "model_qualifier": "SHR 35T", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 56.0, "output_kw_max": 33.6, "final_year_of_manufacture": 2007, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009624", "000227", "0", "2007/Feb/22 09:57", "ATAG Verwarming Nederland BV", "ATAG", "Blauwe Engel", "SHR 35T", "", "1996", "2007", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "33.6", "33.6", "", "", "88.3", "79.7", "", "56.0", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.4", "97.3", "", "", "", "", "95.6"]} +{"pcdb_id": 9625, "brand_name": "ATAG", "model_name": "Blauwe Engel", "model_qualifier": "SHR 51T", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 56.2, "output_kw_max": 48.7, "final_year_of_manufacture": 2007, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009625", "000227", "0", "2018/Apr/25 14:45", "ATAG Verwarming Nederland BV", "ATAG", "Blauwe Engel", "SHR 51T", "", "1996", "2007", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "48.7", "48.7", "", "", "88.5", "79.9", "", "56.2", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.6", "98.1", "", "", "", "", "96.1"]} +{"pcdb_id": 9626, "brand_name": "ATAG", "model_name": "Premier", "model_qualifier": "E-SHR 24", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 23.0, "final_year_of_manufacture": 2007, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009626", "000227", "0", "2012/Mar/27 10:12", "ATAG Verwarming Nederland BV", "ATAG", "Premier", "E-SHR 24", "", "1999", "2007", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "23.0", "23.0", "", "", "88.3", "79.3", "", "57.9", "", "2", "", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.4", "97.3", "", "", "", "", "95.6"]} +{"pcdb_id": 9627, "brand_name": "ATAG", "model_name": "Blauwe Engel", "model_qualifier": "SHR 24T", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 56.3, "output_kw_max": 23.0, "final_year_of_manufacture": 2007, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009627", "000227", "0", "2007/Feb/22 09:56", "ATAG Verwarming Nederland BV", "ATAG", "Blauwe Engel", "SHR 24T", "", "1996", "2007", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "23.0", "23.0", "", "", "88.6", "80.0", "", "56.3", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.5", "98.2", "", "", "", "", "96.4"]} +{"pcdb_id": 9628, "brand_name": "Saunier Duval", "model_name": "Envirotek F28E", "model_qualifier": "", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 56.4, "output_kw_max": 29.0, "final_year_of_manufacture": 2003, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009628", "000206", "0", "2006/Jan/17 12:55", "Hepworth Heating", "Saunier Duval", "Envirotek F28E", "", "GC 47-920-39", "2003", "2003", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "29.0", "29.0", "", "", "88.9", "80.3", "", "56.4", "", "2", "", "", "104", "1", "2", "180", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "0", "", "0005", "", "", "", "", "", "", "", "", "88.4", "98.8", "", "", "", "", "96.9"]} +{"pcdb_id": 9629, "brand_name": "Ferroli", "model_name": "Econcept", "model_qualifier": "50A", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 45.2, "final_year_of_manufacture": 2017, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009629", "000097", "0", "2017/Aug/07 16:56", "Ferroli SpA", "Ferroli", "Econcept", "50A", "", "2002", "2017", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "45.2", "45.2", "", "", "88.6", "79.6", "", "58.2", "", "2", "", "", "102", "1", "2", "190", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.5", "98.2", "", "", "", "", "96.4"]} +{"pcdb_id": 9630, "brand_name": "Saunier Duval", "model_name": "Envirotek F28E SB", "model_qualifier": "", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 29.0, "final_year_of_manufacture": 2003, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009630", "000206", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Saunier Duval", "Envirotek F28E SB", "", "GC 41-920-37", "2003", "2003", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "29.0", "29.0", "", "", "88.9", "79.9", "", "58.3", "", "2", "", "", "102", "1", "2", "180", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.4", "98.8", "", "", "", "", "96.9"]} +{"pcdb_id": 9631, "brand_name": "Vaillant", "model_name": "Thermocompact", "model_qualifier": "637 E", "winter_efficiency_pct": 80.9, "summer_efficiency_pct": 70.2, "comparative_hot_water_efficiency_pct": 51.3, "output_kw_max": 36.9, "final_year_of_manufacture": 2010, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009631", "000031", "0", "2012/Mar/27 10:12", "Vaillant", "Vaillant", "Thermocompact", "637 E", "VU GB 362/2-5", "2003", "2010", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "36.9", "36.9", "", "", "80.9", "70.2", "", "51.3", "", "2", "", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.0", "81.8", "", "", "", "", "81.8"]} +{"pcdb_id": 9632, "brand_name": "British Gas", "model_name": "RD628", "model_qualifier": "RSF", "winter_efficiency_pct": 79.3, "summer_efficiency_pct": 69.2, "comparative_hot_water_efficiency_pct": 48.6, "output_kw_max": 28.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009632", "000035", "0", "2006/Jan/17 12:31", "Worcester Heat Systems", "British Gas", "RD628", "RSF", "47 108 14", "2003", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "28", "28", "", "", "79.3", "69.2", "", "48.6", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.3", "78.7", "", "", "", "", "79.3"]} +{"pcdb_id": 9634, "brand_name": "Coopra BV", "model_name": "Biasi Riva Condensing", "model_qualifier": "M101.31 S (P)", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 56.3, "output_kw_max": 24.5, "final_year_of_manufacture": 2002, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009634", "000208", "0", "2008/May/22 11:19", "Coopra BV", "Coopra BV", "Biasi Riva Condensing", "M101.31 S (P)", "", "1997", "2002", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.5", "24.5", "", "", "88.7", "80.1", "", "56.3", "", "2", "", "", "104", "1", "2", "65", "10", "0", "", "", "0", "0", "0", "", "0", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.0", "98.0", "", "", "", "", "96.3"]} +{"pcdb_id": 9635, "brand_name": "Coopra BV", "model_name": "Biasi Riva Condensing", "model_qualifier": "M101.31 SR (P)", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 24.5, "final_year_of_manufacture": 2002, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009635", "000208", "0", "2012/Mar/27 10:12", "Coopra BV", "Coopra BV", "Biasi Riva Condensing", "M101.31 SR (P)", "", "1997", "2002", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24.5", "24.5", "", "", "88.7", "79.7", "", "58.2", "", "2", "", "", "102", "1", "2", "65", "10", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.0", "98.0", "", "", "", "", "96.3"]} +{"pcdb_id": 9636, "brand_name": "Coopra BV", "model_name": "Biasi Riva Condensing", "model_qualifier": "M101.31 SRB (P)", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 24.5, "final_year_of_manufacture": 2002, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009636", "000208", "0", "2012/Mar/27 10:12", "Coopra BV", "Coopra BV", "Biasi Riva Condensing", "M101.31 SRB (P)", "", "1997", "2002", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24.5", "24.5", "", "", "88.7", "79.7", "", "58.2", "", "2", "", "", "102", "1", "2", "65", "10", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.0", "98.0", "", "", "", "", "96.3"]} +{"pcdb_id": 9637, "brand_name": "Biasi", "model_name": "Garda", "model_qualifier": "M90F. 28SR", "winter_efficiency_pct": 81.2, "summer_efficiency_pct": 70.5, "comparative_hot_water_efficiency_pct": 51.5, "output_kw_max": 28.4, "final_year_of_manufacture": 2007, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009637", "000208", "0", "2012/Mar/27 10:12", "Biasi SpA", "Biasi", "Garda", "M90F. 28SR", "41-970-11", "2002", "2007", "2", "2", "1", "1", "0", "", "", "1", "2", "2", "28.4", "28.4", "", "", "81.2", "70.5", "", "51.5", "", "2", "1", "", "102", "1", "2", "170", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "84.0", "80.3", "", "", "", "", "81.0"]} +{"pcdb_id": 9638, "brand_name": "Biasi", "model_name": "Garda", "model_qualifier": "M90F. 28S", "winter_efficiency_pct": 81.0, "summer_efficiency_pct": 70.9, "comparative_hot_water_efficiency_pct": 49.8, "output_kw_max": 28.4, "final_year_of_manufacture": 2007, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009638", "000208", "0", "2008/May/22 11:38", "Biasi SpA", "Biasi", "Garda", "M90F. 28S", "47-970-20", "2002", "2007", "2", "2", "1", "2", "0", "", "", "1", "2", "2", "28.4", "28.4", "", "", "81.0", "70.9", "", "49.8", "", "2", "1", "", "104", "1", "2", "170", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "84.0", "80.3", "", "", "", "", "81.0"]} +{"pcdb_id": 9639, "brand_name": "Biasi", "model_name": "Garda", "model_qualifier": "M90F. 24SR", "winter_efficiency_pct": 81.1, "summer_efficiency_pct": 70.4, "comparative_hot_water_efficiency_pct": 51.4, "output_kw_max": 24.3, "final_year_of_manufacture": 2007, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009639", "000208", "0", "2012/Mar/27 10:12", "Biasi SpA", "Biasi", "Garda", "M90F. 24SR", "41-970-10", "2002", "2007", "2", "2", "1", "1", "0", "", "", "1", "2", "2", "24.3", "24.3", "", "", "81.1", "70.4", "", "51.4", "", "2", "1", "", "102", "1", "2", "150", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "84.1", "80.1", "", "", "", "", "80.9"]} +{"pcdb_id": 9640, "brand_name": "Biasi", "model_name": "Garda", "model_qualifier": "M90F. 24S", "winter_efficiency_pct": 80.9, "summer_efficiency_pct": 70.8, "comparative_hot_water_efficiency_pct": 49.8, "output_kw_max": 24.3, "final_year_of_manufacture": 2007, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009640", "000208", "0", "2008/May/22 11:39", "Biasi SpA", "Biasi", "Garda", "M90F. 24S", "47-970-19", "2002", "2007", "2", "2", "1", "2", "0", "", "", "1", "2", "2", "24.3", "24.3", "", "", "80.9", "70.8", "", "49.8", "", "2", "1", "", "104", "1", "2", "150", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "84.1", "80.1", "", "", "", "", "80.9"]} +{"pcdb_id": 9641, "brand_name": "Biasi", "model_name": "Riva Compact", "model_qualifier": "M90E. 28S", "winter_efficiency_pct": 81.0, "summer_efficiency_pct": 70.9, "comparative_hot_water_efficiency_pct": 49.8, "output_kw_max": 28.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009641", "000208", "0", "2006/Jan/17 12:31", "Biasi SpA", "Biasi", "Riva Compact", "M90E. 28S", "47-970-18", "2002", "current", "2", "2", "1", "2", "0", "", "", "1", "2", "2", "28.4", "28.4", "", "", "81.0", "70.9", "", "49.8", "", "2", "1", "", "104", "1", "2", "170", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "84.0", "80.3", "", "", "", "", "81.0"]} +{"pcdb_id": 9642, "brand_name": "Biasi", "model_name": "Riva Compact", "model_qualifier": "M90E. 24S", "winter_efficiency_pct": 80.9, "summer_efficiency_pct": 70.8, "comparative_hot_water_efficiency_pct": 49.8, "output_kw_max": 24.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009642", "000208", "0", "2006/Jan/17 12:31", "Biasi SpA", "Biasi", "Riva Compact", "M90E. 24S", "47-970-17", "2002", "current", "2", "2", "1", "2", "0", "", "", "1", "2", "2", "24.3", "24.3", "", "", "80.9", "70.8", "", "49.8", "", "2", "1", "", "104", "1", "2", "150", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "84.1", "80.1", "", "", "", "", "80.9"]} +{"pcdb_id": 9643, "brand_name": "Biasi", "model_name": "Riva Plus", "model_qualifier": "M90D. 28SR", "winter_efficiency_pct": 81.2, "summer_efficiency_pct": 70.5, "comparative_hot_water_efficiency_pct": 51.5, "output_kw_max": 28.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009643", "000208", "0", "2012/Mar/27 10:12", "Biasi SpA", "Biasi", "Riva Plus", "M90D. 28SR", "41-970-09", "2002", "current", "2", "2", "1", "1", "0", "", "", "1", "2", "2", "28.4", "28.4", "", "", "81.2", "70.5", "", "51.5", "", "2", "1", "", "102", "1", "2", "170", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "84.0", "80.3", "", "", "", "", "81.0"]} +{"pcdb_id": 9644, "brand_name": "Biasi", "model_name": "Riva Plus", "model_qualifier": "M90D. 28S", "winter_efficiency_pct": 81.0, "summer_efficiency_pct": 70.9, "comparative_hot_water_efficiency_pct": 49.8, "output_kw_max": 28.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009644", "000208", "0", "2006/Jan/17 12:31", "Biasi SpA", "Biasi", "Riva Plus", "M90D. 28S", "47-970-16", "2002", "current", "2", "2", "1", "2", "0", "", "", "1", "2", "2", "28.4", "28.4", "", "", "81.0", "70.9", "", "49.8", "", "2", "1", "", "104", "1", "2", "170", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "84.0", "80.3", "", "", "", "", "81.0"]} +{"pcdb_id": 9645, "brand_name": "Biasi", "model_name": "Riva Plus", "model_qualifier": "M90D. 24S", "winter_efficiency_pct": 80.9, "summer_efficiency_pct": 70.8, "comparative_hot_water_efficiency_pct": 49.8, "output_kw_max": 24.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009645", "000208", "0", "2006/Jan/17 12:31", "Biasi SpA", "Biasi", "Riva Plus", "M90D. 24S", "47-970-15", "2002", "current", "2", "2", "1", "2", "0", "", "", "1", "2", "2", "24.3", "24.3", "", "", "80.9", "70.8", "", "49.8", "", "2", "1", "", "104", "1", "2", "150", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "84.1", "80.1", "", "", "", "", "80.9"]} +{"pcdb_id": 9646, "brand_name": "Biasi", "model_name": "Riva Plus", "model_qualifier": "M90D. 24SR", "winter_efficiency_pct": 81.1, "summer_efficiency_pct": 70.4, "comparative_hot_water_efficiency_pct": 51.4, "output_kw_max": 24.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009646", "000208", "0", "2012/Mar/27 10:12", "Biasi SpA", "Biasi", "Riva Plus", "M90D. 24SR", "41-970-08", "2002", "current", "2", "2", "1", "1", "0", "", "", "1", "2", "2", "24.3", "24.3", "", "", "81.1", "70.4", "", "51.4", "", "2", "1", "", "102", "1", "2", "150", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "84.1", "80.1", "", "", "", "", "80.9"]} +{"pcdb_id": 9647, "brand_name": "Vaillant", "model_name": "Aquaplus", "model_qualifier": "", "winter_efficiency_pct": 80.7, "summer_efficiency_pct": 70.6, "comparative_hot_water_efficiency_pct": 49.6, "output_kw_max": 36.9, "final_year_of_manufacture": 2010, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009647", "000031", "0", "2010/Jan/28 08:40", "Vaillant", "Vaillant", "Aquaplus", "", "VUI GB 362-7", "2003", "2010", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "36.9", "36.9", "", "", "80.7", "70.6", "", "49.6", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.0", "81.8", "", "", "", "", "81.8"]} +{"pcdb_id": 9648, "brand_name": "Strebel", "model_name": "SC 30 K", "model_qualifier": "", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 56.3, "output_kw_max": 25.9, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009648", "000228", "0", "2010/Sep/28 09:35", "Strebel", "Strebel", "SC 30 K", "", "", "1996", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "25.9", "25.9", "", "", "88.7", "80.1", "", "56.3", "", "2", "", "", "104", "1", "2", "136", "", "0", "", "", "3", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "0", "", "0005", "", "", "", "", "", "", "", "", "89.0", "98.0", "", "", "", "", "96.3"]} +{"pcdb_id": 9649, "brand_name": "Strebel", "model_name": "SC 30 C", "model_qualifier": "", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 25.9, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009649", "000228", "0", "2012/Mar/27 10:12", "Strebel", "Strebel", "SC 30 C", "", "", "1996", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "25.9", "25.9", "", "", "88.7", "79.7", "", "58.2", "", "2", "", "", "102", "1", "2", "136", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.0", "98.0", "", "", "", "", "96.3"]} +{"pcdb_id": 9650, "brand_name": "Strebel", "model_name": "SC 30 B", "model_qualifier": "", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 25.9, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009650", "000228", "0", "2012/Mar/27 10:12", "Strebel", "Strebel", "SC 30 B", "", "", "1996", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "25.9", "25.9", "", "", "88.7", "79.7", "", "58.2", "", "2", "", "", "102", "1", "2", "136", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.0", "98.0", "", "", "", "", "96.3"]} +{"pcdb_id": 9651, "brand_name": "ATAG", "model_name": "Premier", "model_qualifier": "E-SHR15", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 14.4, "final_year_of_manufacture": 2007, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009651", "000227", "0", "2012/Mar/27 10:12", "ATAG Verwarming Nederland BV", "ATAG", "Premier", "E-SHR15", "", "1999", "2007", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "14.4", "14.4", "", "", "88.6", "79.6", "", "58.2", "", "2", "", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.5", "98.2", "", "", "", "", "96.4"]} +{"pcdb_id": 9652, "brand_name": "DD Heating", "model_name": "Heatline", "model_qualifier": "S24 Compact", "winter_efficiency_pct": 80.8, "summer_efficiency_pct": 70.7, "comparative_hot_water_efficiency_pct": 49.7, "output_kw_max": 24.0, "final_year_of_manufacture": 2007, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009652", "000215", "0", "2011/Aug/31 10:44", "Turk Demir Dokum Fab AS", "DD Heating", "Heatline", "S24 Compact", "", "2003", "2007", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "24", "24", "", "", "80.8", "70.7", "", "49.7", "", "2", "", "", "104", "1", "2", "164", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "84.1", "81.2", "", "", "", "", "81.7"]} +{"pcdb_id": 9653, "brand_name": "DD Heating", "model_name": "Heatline", "model_qualifier": "S30 Compact", "winter_efficiency_pct": 79.9, "summer_efficiency_pct": 69.8, "comparative_hot_water_efficiency_pct": 49.1, "output_kw_max": 30.0, "final_year_of_manufacture": 2007, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009653", "000215", "0", "2011/Aug/31 10:45", "Turk Demir Dokum Fab AS", "DD Heating", "Heatline", "S30 Compact", "", "2003", "2007", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "30", "30", "", "", "79.9", "69.8", "", "49.1", "", "2", "", "", "104", "1", "2", "164", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "84.3", "79.3", "", "", "", "", "80.2"]} +{"pcdb_id": 9654, "brand_name": "DD Heating", "model_name": "Heatline", "model_qualifier": "S20 Compact", "winter_efficiency_pct": 80.2, "summer_efficiency_pct": 70.1, "comparative_hot_water_efficiency_pct": 49.3, "output_kw_max": 20.0, "final_year_of_manufacture": 2007, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009654", "000215", "0", "2011/Aug/31 10:44", "Turk Demir Dokum Fab AS", "DD Heating", "Heatline", "S20 Compact", "", "2003", "2007", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "20", "20", "", "", "80.2", "70.1", "", "49.3", "", "2", "", "", "104", "1", "2", "164", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "83.9", "79.8", "", "", "", "", "80.6"]} +{"pcdb_id": 9655, "brand_name": "Sile SpA", "model_name": "Condensa 23 R", "model_qualifier": "", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 56.0, "output_kw_max": 22.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009655", "000221", "0", "2008/Sep/29 16:01", "Sile SpA", "Sile SpA", "Condensa 23 R", "", "", "2002", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "22", "22", "", "", "88.2", "79.6", "", "56.0", "", "2", "", "", "104", "1", "2", "175", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "97.4", "", "", "", "", "95.6"]} +{"pcdb_id": 9656, "brand_name": "Sile SpA", "model_name": "Condensa 23 BI", "model_qualifier": "", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 80.9, "comparative_hot_water_efficiency_pct": 43.1, "output_kw_max": 22.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009656", "000221", "0", "2024/Jan/31 10:17", "Sile SpA", "Sile SpA", "Condensa 23 BI", "", "", "2002", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "22", "22", "", "", "88.2", "80.9", "", "43.1", "", "2", "", "", "106", "1", "2", "175", "", "2", "1", "0", "48", "0", "15", "4", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "97.4", "", "", "", "", "95.6"]} +{"pcdb_id": 9657, "brand_name": "Sile SpA", "model_name": "Condensa 23 N", "model_qualifier": "", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 22.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009657", "000221", "0", "2012/Mar/27 10:12", "Sile SpA", "Sile SpA", "Condensa 23 N", "", "", "2002", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "22", "22", "", "", "88.2", "79.2", "", "57.9", "", "2", "", "", "102", "1", "2", "175", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "97.4", "", "", "", "", "95.6"]} +{"pcdb_id": 9658, "brand_name": "Sile SpA", "model_name": "Condensa 32 N", "model_qualifier": "", "winter_efficiency_pct": 87.7, "summer_efficiency_pct": 78.7, "comparative_hot_water_efficiency_pct": 57.5, "output_kw_max": 30.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009658", "000221", "0", "2012/Mar/27 10:12", "Sile SpA", "Sile SpA", "Condensa 32 N", "", "", "2002", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "30.0", "30.0", "", "", "87.7", "78.7", "", "57.5", "", "2", "", "", "102", "1", "2", "175", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "96.0", "", "", "", "", "94.5"]} +{"pcdb_id": 9659, "brand_name": "Sile SpA", "model_name": "Condensa 32 BI", "model_qualifier": "", "winter_efficiency_pct": 87.7, "summer_efficiency_pct": 80.4, "comparative_hot_water_efficiency_pct": 42.8, "output_kw_max": 30.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009659", "000221", "0", "2024/Jan/31 10:17", "Sile SpA", "Sile SpA", "Condensa 32 BI", "", "", "2002", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "30", "30", "", "", "87.7", "80.4", "", "42.8", "", "2", "", "", "106", "1", "2", "175", "0", "2", "1", "0", "48", "0", "15", "4", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "96.0", "", "", "", "", "94.5"]} +{"pcdb_id": 9660, "brand_name": "Sile SpA", "model_name": "Condensa 32 Maxi", "model_qualifier": "", "winter_efficiency_pct": 87.7, "summer_efficiency_pct": 80.4, "comparative_hot_water_efficiency_pct": 35.0, "output_kw_max": 30.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009660", "000221", "0", "2024/Jan/31 10:17", "Sile SpA", "Sile SpA", "Condensa 32 Maxi", "", "", "2002", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "30", "30", "", "", "87.7", "80.4", "", "35.0", "", "2", "", "", "106", "1", "2", "175", "0", "2", "1", "0", "120", "0", "15", "4", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "96.0", "", "", "", "", "94.5"]} +{"pcdb_id": 9661, "brand_name": "Trianco", "model_name": "Eurostar Premier 50/90", "model_qualifier": "50/90 Condensing Boiler", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 27.9, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009661", "000062", "0", "2012/Mar/27 10:12", "Trianco Redfyre", "Trianco", "Eurostar Premier 50/90", "50/90 Condensing Boiler", "", "2003", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "15.7", "27.9", "", "", "88.0", "80.2", "", "58.6", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.0", "95.1", "", "", "", "", "94.1"]} +{"pcdb_id": 9663, "brand_name": "ATAG", "model_name": "Blauwe Engel", "model_qualifier": "SHR 51 L", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 48.7, "final_year_of_manufacture": 2007, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009663", "000227", "0", "2012/Mar/27 10:12", "ATAG Verwarming Nederland bv", "ATAG", "Blauwe Engel", "SHR 51 L", "", "1996", "2007", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "48.7", "48.7", "", "", "88.3", "79.3", "", "58.0", "", "2", "", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "97.8", "", "", "", "", "95.9"]} +{"pcdb_id": 9664, "brand_name": "ATAG", "model_name": "Blauwe Engel", "model_qualifier": "SHR 51 TL", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 48.7, "final_year_of_manufacture": 2007, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009664", "000227", "0", "2012/Mar/27 10:12", "ATAG Verwarming Nederland bv", "ATAG", "Blauwe Engel", "SHR 51 TL", "", "1996", "2007", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "48.7", "48.7", "", "", "88.3", "79.3", "", "58.0", "", "2", "", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "97.8", "", "", "", "", "95.9"]} +{"pcdb_id": 9665, "brand_name": "Chaffoteaux et Maury", "model_name": "Britony System II 100", "model_qualifier": "", "winter_efficiency_pct": 79.5, "summer_efficiency_pct": 68.8, "comparative_hot_water_efficiency_pct": 50.3, "output_kw_max": 28.0, "final_year_of_manufacture": 2007, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009665", "000010", "0", "2012/Mar/27 10:12", "Chaffoteaux et Maury", "Chaffoteaux et Maury", "Britony System II 100", "", "GC No. 41-980-17", "2002", "2007", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "28", "28", "", "", "79.5", "68.8", "", "50.3", "", "2", "", "", "102", "1", "2", "150", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.5", "78.5", "", "", "", "", "79.2"]} +{"pcdb_id": 9666, "brand_name": "Chaffoteaux et Maury", "model_name": "Britony System II Plus 100", "model_qualifier": "", "winter_efficiency_pct": 79.5, "summer_efficiency_pct": 68.8, "comparative_hot_water_efficiency_pct": 50.3, "output_kw_max": 28.0, "final_year_of_manufacture": 2007, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009666", "000010", "0", "2012/Mar/27 10:12", "Chaffoteaux et Maury", "Chaffoteaux et Maury", "Britony System II Plus 100", "", "GC No. 41-980-25", "2002", "2007", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "28", "28", "", "", "79.5", "68.8", "", "50.3", "", "2", "", "", "102", "1", "2", "150", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.5", "78.5", "", "", "", "", "79.2"]} +{"pcdb_id": 9667, "brand_name": "Chaffoteaux et Maury", "model_name": "Calydra Comfort 100", "model_qualifier": "", "winter_efficiency_pct": 79.3, "summer_efficiency_pct": 69.2, "comparative_hot_water_efficiency_pct": 48.7, "output_kw_max": 28.0, "final_year_of_manufacture": 2007, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009667", "000010", "0", "2007/Jun/18 09:12", "Chaffoteaux et Maury", "Chaffoteaux et Maury", "Calydra Comfort 100", "", "GC No. 47-980-23", "2002", "2007", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "28", "28", "", "", "79.3", "69.2", "", "48.7", "", "2", "", "", "104", "1", "2", "150", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.5", "78.5", "", "", "", "", "79.2"]} +{"pcdb_id": 9668, "brand_name": "Chaffoteaux et Maury", "model_name": "Britony System II 80", "model_qualifier": "", "winter_efficiency_pct": 79.8, "summer_efficiency_pct": 69.1, "comparative_hot_water_efficiency_pct": 50.5, "output_kw_max": 24.0, "final_year_of_manufacture": 2007, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009668", "000010", "0", "2012/Mar/27 10:12", "Chaffoteaux et Maury", "Chaffoteaux et Maury", "Britony System II 80", "", "GC No. 41-980-15", "2002", "2007", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "24", "24", "", "", "79.8", "69.1", "", "50.5", "", "2", "", "", "102", "1", "2", "150", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.6", "78.9", "", "", "", "", "79.6"]} +{"pcdb_id": 9669, "brand_name": "Chaffoteaux et Maury", "model_name": "Britony System II Plus 80", "model_qualifier": "", "winter_efficiency_pct": 79.8, "summer_efficiency_pct": 69.1, "comparative_hot_water_efficiency_pct": 50.5, "output_kw_max": 24.0, "final_year_of_manufacture": 2007, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009669", "000010", "0", "2012/Mar/27 10:12", "Chaffoteaux et Maury", "Chaffoteaux et Maury", "Britony System II Plus 80", "", "GC No. 41-980-16", "2002", "2007", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "24", "24", "", "", "79.8", "69.1", "", "50.5", "", "2", "", "", "102", "1", "2", "150", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.6", "78.9", "", "", "", "", "79.6"]} +{"pcdb_id": 9670, "brand_name": "Beeston", "model_name": "Solution 2000", "model_qualifier": "S-HR15", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 14.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009670", "000230", "0", "2012/Mar/27 10:12", "ATAG Verwarming Nederland BV", "Beeston", "Solution 2000", "S-HR15", "", "1997", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "14.5", "14.5", "", "", "88.6", "79.6", "", "58.2", "", "2", "", "", "102", "1", "2", "122", "5", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.5", "98.2", "", "", "", "", "96.4"]} +{"pcdb_id": 9671, "brand_name": "Beeston", "model_name": "Solution 2000", "model_qualifier": "S-HR24", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 23.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009671", "000230", "0", "2012/Mar/27 10:12", "ATAG Verwarming Nederland BV", "Beeston", "Solution 2000", "S-HR24", "", "1997", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "23.0", "23.0", "", "", "88.6", "79.6", "", "58.2", "", "2", "", "", "102", "1", "2", "122", "5", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.5", "98.2", "", "", "", "", "96.4"]} +{"pcdb_id": 9672, "brand_name": "Beeston", "model_name": "Solution 2000", "model_qualifier": "S-HR24T", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 23.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009672", "000230", "0", "2012/Mar/27 10:12", "ATAG Verwarming Nederland BV", "Beeston", "Solution 2000", "S-HR24T", "", "1997", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "23.0", "23.0", "", "", "88.6", "79.6", "", "58.2", "", "2", "", "", "102", "1", "2", "122", "5", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.5", "98.2", "", "", "", "", "96.4"]} +{"pcdb_id": 9673, "brand_name": "Beeston", "model_name": "Solution 2000", "model_qualifier": "S-HR35", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 33.8, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009673", "000230", "0", "2012/Mar/27 10:12", "ATAG Verwarming Nederland BV", "Beeston", "Solution 2000", "S-HR35", "", "1997", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "33.8", "33.8", "", "", "88.3", "79.3", "", "57.9", "", "2", "", "", "102", "1", "2", "145", "5", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.4", "97.3", "", "", "", "", "95.6"]} +{"pcdb_id": 9674, "brand_name": "Beeston", "model_name": "Solution 2000", "model_qualifier": "S-HR35T", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 56.0, "output_kw_max": 33.8, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009674", "000230", "0", "2006/Jan/17 12:31", "ATAG Verwarming Nederland BV", "Beeston", "Solution 2000", "S-HR35T", "", "1997", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "33.8", "33.8", "", "", "88.3", "79.7", "", "56.0", "", "2", "", "", "104", "1", "2", "145", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.4", "97.3", "", "", "", "", "95.6"]} +{"pcdb_id": 9675, "brand_name": "Beeston", "model_name": "Solution 2000", "model_qualifier": "S-HR51", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 48.8, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009675", "000230", "0", "2012/Mar/27 10:12", "ATAG Verwarming Nederland BV", "Beeston", "Solution 2000", "S-HR51", "", "1997", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "48.8", "48.8", "", "", "88.5", "79.5", "", "58.0", "", "2", "", "", "102", "1", "2", "190", "5", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.6", "98.1", "", "", "", "", "96.1"]} +{"pcdb_id": 9676, "brand_name": "Beeston", "model_name": "Solution 2000", "model_qualifier": "S-HR51T", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 56.2, "output_kw_max": 48.8, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009676", "000230", "0", "2006/Jan/17 12:31", "ATAG Verwarming Nederland BV", "Beeston", "Solution 2000", "S-HR51T", "", "1997", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "48.8", "48.8", "", "", "88.5", "79.9", "", "56.2", "", "2", "", "", "104", "1", "2", "190", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.6", "98.1", "", "", "", "", "96.1"]} +{"pcdb_id": 9677, "brand_name": "Beeston", "model_name": "Solution 2000", "model_qualifier": "S-HR60", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 57.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009677", "000230", "0", "2012/Mar/27 10:12", "ATAG Verwarming Nederland BV", "Beeston", "Solution 2000", "S-HR60", "", "1997", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "57.4", "57.4", "", "", "88.3", "79.3", "", "57.9", "", "2", "", "", "102", "1", "2", "190", "5", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.1", "97.5", "", "", "", "", "95.7"]} +{"pcdb_id": 9678, "brand_name": "Trianco", "model_name": "Eurostar Premier", "model_qualifier": "50/90 Condensing System Boiler", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 27.9, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009678", "000062", "0", "2012/Mar/27 10:12", "Trianco Redfyre", "Trianco", "Eurostar Premier", "50/90 Condensing System Boiler", "", "2003", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "15.7", "27.9", "", "", "88.0", "80.2", "", "58.6", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.0", "95.1", "", "", "", "", "94.1"]} +{"pcdb_id": 9679, "brand_name": "Fontecal", "model_name": "Corolla 30", "model_qualifier": "A", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 81.7, "comparative_hot_water_efficiency_pct": 41.5, "output_kw_max": 26.54, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009679", "000231", "0", "2024/Jan/31 10:17", "Fontecal SpA", "Fontecal", "Corolla 30", "A", "", "2001", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "26.54", "26.54", "", "", "88.7", "81.7", "", "41.5", "", "2", "", "", "106", "1", "2", "65", "0.1", "2", "2", "0", "50", "0", "13", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.6", "98.4", "", "", "", "", "96.5"]} +{"pcdb_id": 9680, "brand_name": "Fontecal", "model_name": "Corolla 30", "model_qualifier": "P", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 56.3, "output_kw_max": 26.54, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009680", "000231", "0", "2006/Jan/17 12:31", "Fontecal SpA", "Fontecal", "Corolla 30", "P", "", "2001", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "26.54", "26.54", "", "", "88.7", "80.1", "", "56.3", "", "2", "", "", "104", "1", "2", "65", "0.1", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.6", "98.4", "", "", "", "", "96.5"]} +{"pcdb_id": 9681, "brand_name": "Fontecal", "model_name": "Corolla 30", "model_qualifier": "S", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 26.54, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009681", "000231", "0", "2012/Mar/27 10:12", "Fontecal SpA", "Fontecal", "Corolla 30", "S", "", "2001", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "26.54", "26.54", "", "", "88.7", "79.7", "", "58.2", "", "2", "", "", "102", "1", "2", "65", "0.1", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.6", "98.4", "", "", "", "", "96.5"]} +{"pcdb_id": 9695, "brand_name": "Fontecal", "model_name": "Polycal 26", "model_qualifier": "A 50", "winter_efficiency_pct": 82.9, "summer_efficiency_pct": 74.8, "comparative_hot_water_efficiency_pct": 38.0, "output_kw_max": 29.9, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009695", "000231", "0", "2024/Jan/31 10:17", "Fontecal SpA", "Fontecal", "Polycal 26", "A 50", "", "2002", "current", "4", "1", "1", "2", "0", "", "", "1", "2", "2", "29.9", "29.9", "", "", "82.9", "74.8", "", "38.0", "", "2", "", "", "203", "1", "1", "110", "0.1", "2", "2", "0", "50", "0", "13", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.2", "83.8", "", "", "", "", "84.0"]} +{"pcdb_id": 9696, "brand_name": "Fontecal", "model_name": "Polycal 26", "model_qualifier": "A 100", "winter_efficiency_pct": 83.2, "summer_efficiency_pct": 75.1, "comparative_hot_water_efficiency_pct": 32.5, "output_kw_max": 29.9, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009696", "000231", "0", "2024/Jan/31 10:17", "Fontecal SpA", "Fontecal", "Polycal 26", "A 100", "", "2002", "current", "4", "1", "1", "2", "0", "", "", "1", "2", "2", "29.9", "29.9", "", "", "83.2", "75.1", "", "32.5", "", "2", "", "", "203", "1", "1", "110", "0.1", "2", "2", "0", "100", "0", "13", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.2", "83.8", "", "", "", "", "84.0"]} +{"pcdb_id": 9698, "brand_name": "Fontecal", "model_name": "Polycal 26", "model_qualifier": "S", "winter_efficiency_pct": 84.5, "summer_efficiency_pct": 72.8, "comparative_hot_water_efficiency_pct": 53.2, "output_kw_max": 29.9, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009698", "000231", "0", "2012/Mar/27 10:12", "Fontecal SpA", "Fontecal", "Polycal 26", "S", "", "2002", "current", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "29.9", "29.9", "", "", "84.5", "72.8", "", "53.2", "", "2", "", "", "201", "1", "1", "110", "0.1", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.2", "83.8", "", "", "", "", "84.0"]} +{"pcdb_id": 9699, "brand_name": "Fontecal", "model_name": "Polycal 21", "model_qualifier": "A 50", "winter_efficiency_pct": 82.9, "summer_efficiency_pct": 74.8, "comparative_hot_water_efficiency_pct": 38.0, "output_kw_max": 24.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009699", "000231", "0", "2024/Jan/31 10:17", "Fontecal SpA", "Fontecal", "Polycal 21", "A 50", "", "2002", "current", "4", "1", "1", "2", "0", "", "", "1", "2", "2", "24.5", "24.5", "", "", "82.9", "74.8", "", "38.0", "", "2", "", "", "203", "1", "1", "110", "0.1", "2", "2", "0", "50", "0", "13", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.2", "83.8", "", "", "", "", "84.0"]} +{"pcdb_id": 9700, "brand_name": "Fontecal", "model_name": "Polycal 21", "model_qualifier": "A 100", "winter_efficiency_pct": 83.2, "summer_efficiency_pct": 75.1, "comparative_hot_water_efficiency_pct": 32.5, "output_kw_max": 24.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009700", "000231", "0", "2024/Jan/31 10:17", "Fontecal SpA", "Fontecal", "Polycal 21", "A 100", "", "2002", "current", "4", "1", "1", "2", "0", "", "", "1", "2", "2", "24.5", "24.5", "", "", "83.2", "75.1", "", "32.5", "", "2", "", "", "203", "1", "1", "110", "0.1", "2", "2", "0", "100", "0", "13", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.2", "83.8", "", "", "", "", "84.0"]} +{"pcdb_id": 9702, "brand_name": "Fontecal", "model_name": "Polycal 21", "model_qualifier": "S", "winter_efficiency_pct": 84.5, "summer_efficiency_pct": 72.8, "comparative_hot_water_efficiency_pct": 53.2, "output_kw_max": 24.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009702", "000231", "0", "2012/Mar/27 10:12", "Fontecal SpA", "Fontecal", "Polycal 21", "S", "", "2002", "current", "4", "1", "1", "1", "0", "", "", "1", "2", "2", "24.5", "24.5", "", "", "84.5", "72.8", "", "53.2", "", "2", "", "", "201", "1", "1", "110", "0.1", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.2", "83.8", "", "", "", "", "84.0"]} +{"pcdb_id": 9704, "brand_name": "Fontecal", "model_name": "Digit", "model_qualifier": "XER", "winter_efficiency_pct": 83.1, "summer_efficiency_pct": 73.0, "comparative_hot_water_efficiency_pct": 51.3, "output_kw_max": 23.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009704", "000231", "0", "2006/Jan/17 12:31", "Fontecal SpA", "Fontecal", "Digit", "XER", "", "2000", "current", "2", "2", "1", "2", "0", "", "", "1", "2", "2", "23.2", "23.2", "", "", "83.1", "73.0", "", "51.3", "", "2", "0", "", "104", "1", "2", "47", "0.1", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "85.3", "86.6", "", "", "", "", "86.3"]} +{"pcdb_id": 9708, "brand_name": "British Gas", "model_name": "RD", "model_qualifier": "428 System", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 27.7, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009708", "000035", "0", "2012/Mar/27 10:12", "Worcester Heat Systems", "British Gas", "RD", "428 System", "41 108 07", "2003", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "27.7", "27.7", "", "", "88.1", "79.1", "", "57.8", "", "2", "", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.9", "96.8", "", "", "", "", "95.3"]} +{"pcdb_id": 9709, "brand_name": "British Gas", "model_name": "RD", "model_qualifier": "430i System", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 29.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009709", "000035", "0", "2012/Mar/27 10:12", "Worcester Heat Systems", "British Gas", "RD", "430i System", "41 108 06", "2003", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "29.5", "29.5", "", "", "88.1", "79.1", "", "57.8", "", "2", "", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.9", "96.8", "", "", "", "", "95.3"]} +{"pcdb_id": 9710, "brand_name": "British Gas", "model_name": "RD", "model_qualifier": "537i Combi", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 56.5, "output_kw_max": 37.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009710", "000035", "0", "2003/Aug/29 10:20", "Worcester Heat Systems", "British Gas", "RD", "537i Combi", "47 108 11", "2003", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "37.5", "37.5", "", "", "88.9", "80.3", "", "56.5", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.5", "98.9", "", "", "", "", "96.9"]} +{"pcdb_id": 9711, "brand_name": "British Gas", "model_name": "RD", "model_qualifier": "532 Combi", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 56.5, "output_kw_max": 32.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009711", "000035", "0", "2003/Aug/29 10:20", "Worcester Heat Systems", "British Gas", "RD", "532 Combi", "47 108 13", "2003", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "32.5", "32.5", "", "", "88.9", "80.3", "", "56.5", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.5", "98.9", "", "", "", "", "96.9"]} +{"pcdb_id": 9712, "brand_name": "British Gas", "model_name": "RD", "model_qualifier": "532i Combi", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 56.5, "output_kw_max": 32.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009712", "000035", "0", "2003/Aug/29 10:20", "Worcester Heat Systems", "British Gas", "RD", "532i Combi", "47 311 10", "2003", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "32.5", "32.5", "", "", "88.9", "80.3", "", "56.5", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.5", "98.9", "", "", "", "", "96.9"]} +{"pcdb_id": 9713, "brand_name": "British Gas", "model_name": "RD", "model_qualifier": "542i Combi", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 56.1, "output_kw_max": 40.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009713", "000035", "0", "2006/Jan/17 12:31", "Worcester Heat Systems", "British Gas", "RD", "542i Combi", "47 311 12", "2003", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "40.0", "40.0", "", "", "88.3", "79.7", "", "56.1", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "97.7", "", "", "", "", "95.8"]} +{"pcdb_id": 9714, "brand_name": "Worcester", "model_name": "Greenstar R", "model_qualifier": "30HE Plus Combi", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 55.9, "output_kw_max": 29.5, "final_year_of_manufacture": 2006, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009714", "000035", "0", "2020/Sep/04 08:05", "Worcester Heat Systems", "Worcester", "Greenstar R", "30HE Plus Combi", "47 311 79", "2003", "2006", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "29.5", "29.5", "", "", "88.1", "79.5", "", "55.9", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.9", "96.8", "", "", "", "", "95.3"]} +{"pcdb_id": 9715, "brand_name": "Worcester", "model_name": "Greenstar R", "model_qualifier": "35 HE Plus Combi", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 56.5, "output_kw_max": 35.5, "final_year_of_manufacture": 2006, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009715", "000035", "0", "2020/Sep/04 08:05", "Worcester Heat Systems", "Worcester", "Greenstar R", "35 HE Plus Combi", "47 311 80", "2003", "2006", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "35.5", "35.5", "", "", "88.9", "80.3", "", "56.5", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.5", "98.9", "", "", "", "", "96.9"]} +{"pcdb_id": 9716, "brand_name": "Worcester", "model_name": "Greenstar R", "model_qualifier": "25 HE Combi", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 55.9, "output_kw_max": 27.5, "final_year_of_manufacture": 2006, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009716", "000035", "0", "2020/Sep/04 08:05", "Worcester Heat Systems", "Worcester", "Greenstar R", "25 HE Combi", "47 311 77", "2003", "2006", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "27.5", "27.5", "", "", "88.1", "79.5", "", "55.9", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.9", "96.8", "", "", "", "", "95.3"]} +{"pcdb_id": 9717, "brand_name": "Worcester", "model_name": "Greenstar R", "model_qualifier": "29 HE Conventional", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 27.7, "final_year_of_manufacture": 2006, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009717", "000035", "0", "2020/Sep/04 08:06", "Worcester Heat Systems", "Worcester", "Greenstar R", "29 HE Conventional", "41 311 60", "2003", "2006", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "27.7", "27.7", "", "", "88.1", "79.1", "", "57.8", "", "2", "", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.9", "96.8", "", "", "", "", "95.3"]} +{"pcdb_id": 9718, "brand_name": "Worcester", "model_name": "Greenstar R", "model_qualifier": "28 HE System", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 27.7, "final_year_of_manufacture": 2006, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009718", "000035", "0", "2020/Sep/04 08:06", "Worcester Heat Systems", "Worcester", "Greenstar R", "28 HE System", "41 311 62", "2003", "2006", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "27.7", "27.7", "", "", "88.1", "79.1", "", "57.8", "", "2", "", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.9", "96.8", "", "", "", "", "95.3"]} +{"pcdb_id": 9719, "brand_name": "Worcester", "model_name": "Greenstar R", "model_qualifier": "30 HE Combi", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 55.9, "output_kw_max": 29.5, "final_year_of_manufacture": 2006, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009719", "000035", "0", "2020/Sep/04 08:06", "Worcester Heat Systems", "Worcester", "Greenstar R", "30 HE Combi", "47 311 78", "2003", "2006", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "29.5", "29.5", "", "", "88.1", "79.5", "", "55.9", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.9", "96.8", "", "", "", "", "95.3"]} +{"pcdb_id": 9720, "brand_name": "Worcester", "model_name": "Greenstar R", "model_qualifier": "40 HE Plus Combi", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 56.1, "output_kw_max": 40.0, "final_year_of_manufacture": 2006, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009720", "000035", "0", "2020/Sep/04 08:06", "Worcester Heat Systems", "Worcester", "Greenstar R", "40 HE Plus Combi", "47 311 81", "2003", "2006", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "40.0", "40.0", "", "", "88.3", "79.7", "", "56.1", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "97.7", "", "", "", "", "95.8"]} +{"pcdb_id": 9721, "brand_name": "Worcester", "model_name": "Greenstar R", "model_qualifier": "40 HE Conventional", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 40.0, "final_year_of_manufacture": 2006, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009721", "000035", "0", "2020/Sep/04 08:06", "Worcester Heat Systems", "Worcester", "Greenstar R", "40 HE Conventional", "41 311 61", "2003", "2006", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "40.0", "40.0", "", "", "88.3", "79.3", "", "57.9", "", "2", "", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "97.7", "", "", "", "", "95.8"]} +{"pcdb_id": 9722, "brand_name": "Ferroli", "model_name": "Maxima", "model_qualifier": "35C", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 56.4, "output_kw_max": 34.6, "final_year_of_manufacture": 2008, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009722", "000097", "0", "2009/Nov/25 16:29", "Ferroli SpA", "Ferroli", "Maxima", "35C", "", "2003", "2008", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "34.6", "34.6", "", "", "88.9", "80.3", "", "56.4", "", "2", "", "", "104", "1", "2", "150", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "", "0", "0005", "", "", "", "", "", "", "", "", "89.6", "98.3", "", "", "", "", "96.7"]} +{"pcdb_id": 9723, "brand_name": "Vokera", "model_name": "Linea", "model_qualifier": "726", "winter_efficiency_pct": 82.0, "summer_efficiency_pct": 71.9, "comparative_hot_water_efficiency_pct": 50.5, "output_kw_max": 26.0, "final_year_of_manufacture": 2010, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009723", "000011", "0", "2010/Oct/21 11:14", "Vokera", "Vokera", "Linea", "726", "4709440", "2003", "2010", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "26.0", "26.0", "", "", "82.0", "71.9", "", "50.5", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "83.1", "83.4", "", "", "", "", "83.4"]} +{"pcdb_id": 9724, "brand_name": "Vokera", "model_name": "Linea", "model_qualifier": "726 LPG", "winter_efficiency_pct": 83.1, "summer_efficiency_pct": 73.0, "comparative_hot_water_efficiency_pct": 51.3, "output_kw_max": 26.0, "final_year_of_manufacture": 2010, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009724", "000011", "0", "2010/Oct/21 11:14", "Vokera", "Vokera", "Linea", "726 LPG", "4709441", "2003", "2010", "2", "2", "1", "2", "0", "", "", "1", "2", "2", "26.0", "26.0", "", "", "83.1", "73.0", "", "51.3", "", "2", "0", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "86.1", "87.3", "", "", "", "", "87.1"]} +{"pcdb_id": 9725, "brand_name": "Vokera", "model_name": "Linea", "model_qualifier": "730", "winter_efficiency_pct": 82.7, "summer_efficiency_pct": 72.6, "comparative_hot_water_efficiency_pct": 51.0, "output_kw_max": 30.1, "final_year_of_manufacture": 2010, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009725", "000011", "0", "2010/Oct/21 11:14", "Vokera", "Vokera", "Linea", "730", "4709442", "2003", "2010", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "30.1", "30.1", "", "", "82.7", "72.6", "", "51.0", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "83.3", "84.9", "", "", "", "", "84.6"]} +{"pcdb_id": 9726, "brand_name": "Vokera", "model_name": "Linea", "model_qualifier": "730 LPG", "winter_efficiency_pct": 83.1, "summer_efficiency_pct": 73.0, "comparative_hot_water_efficiency_pct": 51.3, "output_kw_max": 30.1, "final_year_of_manufacture": 2010, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009726", "000011", "0", "2010/Oct/21 11:14", "Vokera", "Vokera", "Linea", "730 LPG", "4709443", "2003", "2010", "2", "2", "1", "2", "0", "", "", "1", "2", "2", "30.1", "30.1", "", "", "83.1", "73.0", "", "51.3", "", "2", "0", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "85.8", "87.0", "", "", "", "", "86.8"]} +{"pcdb_id": 9727, "brand_name": "Vokera", "model_name": "Linea", "model_qualifier": "735", "winter_efficiency_pct": 82.8, "summer_efficiency_pct": 72.7, "comparative_hot_water_efficiency_pct": 51.1, "output_kw_max": 35.2, "final_year_of_manufacture": 2010, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009727", "000011", "0", "2010/Oct/21 11:14", "Vokera", "Vokera", "Linea", "735", "4709444", "2003", "2010", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "35.2", "35.2", "", "", "82.8", "72.7", "", "51.1", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "84.0", "85.1", "", "", "", "", "84.9"]} +{"pcdb_id": 9728, "brand_name": "Vokera", "model_name": "Linea", "model_qualifier": "735 LPG", "winter_efficiency_pct": 83.1, "summer_efficiency_pct": 73.0, "comparative_hot_water_efficiency_pct": 51.3, "output_kw_max": 35.2, "final_year_of_manufacture": 2010, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009728", "000011", "0", "2010/Oct/21 11:15", "Vokera", "Vokera", "Linea", "735 LPG", "4709445", "2003", "2010", "2", "2", "1", "2", "0", "", "", "1", "2", "2", "35.2", "35.2", "", "", "83.1", "73.0", "", "51.3", "", "2", "0", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "86.2", "88.0", "", "", "", "", "87.6"]} +{"pcdb_id": 9729, "brand_name": "Vokera", "model_name": "Mynute", "model_qualifier": "35e", "winter_efficiency_pct": 83.0, "summer_efficiency_pct": 72.3, "comparative_hot_water_efficiency_pct": 52.8, "output_kw_max": 35.2, "final_year_of_manufacture": 2010, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009729", "000011", "0", "2012/Mar/27 10:12", "Vokera", "Vokera", "Mynute", "35e", "4109429", "2003", "2010", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "35.2", "35.2", "", "", "83.0", "72.3", "", "52.8", "", "2", "", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "84.0", "85.1", "", "", "", "", "84.9"]} +{"pcdb_id": 9730, "brand_name": "Vokera", "model_name": "Mynute", "model_qualifier": "35e LPG", "winter_efficiency_pct": 83.3, "summer_efficiency_pct": 72.6, "comparative_hot_water_efficiency_pct": 53.0, "output_kw_max": 35.2, "final_year_of_manufacture": 2010, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009730", "000011", "0", "2012/Mar/27 10:12", "Vokera", "Vokera", "Mynute", "35e LPG", "4109430", "2003", "2010", "2", "2", "1", "1", "0", "", "", "1", "2", "2", "35.2", "35.2", "", "", "83.3", "72.6", "", "53.0", "", "2", "0", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "86.2", "88.0", "", "", "", "", "87.6"]} +{"pcdb_id": 9731, "brand_name": "Biasi", "model_name": "Garda", "model_qualifier": "M90F. 32S", "winter_efficiency_pct": 79.2, "summer_efficiency_pct": 69.1, "comparative_hot_water_efficiency_pct": 48.6, "output_kw_max": 35.2, "final_year_of_manufacture": 2007, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009731", "000208", "0", "2008/May/22 11:33", "Biasi", "Biasi", "Garda", "M90F. 32S", "47-970-22", "2003", "2007", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "35.2", "35.2", "", "", "79.2", "69.1", "", "48.6", "", "2", "", "", "104", "1", "2", "180", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.0", "78.7", "", "", "", "", "79.4"]} +{"pcdb_id": 9732, "brand_name": "Biasi", "model_name": "Riva Compact", "model_qualifier": "M90E. 32S", "winter_efficiency_pct": 79.2, "summer_efficiency_pct": 69.1, "comparative_hot_water_efficiency_pct": 48.6, "output_kw_max": 35.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009732", "000208", "0", "2006/Jan/17 12:31", "Biasi", "Biasi", "Riva Compact", "M90E. 32S", "47-970-21", "2003", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "35.2", "35.2", "", "", "79.2", "69.1", "", "48.6", "", "2", "", "", "104", "1", "2", "180", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.0", "78.7", "", "", "", "", "79.4"]} +{"pcdb_id": 9733, "brand_name": "Grant", "model_name": "Vortex", "model_qualifier": "Utility 15-26", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 81.3, "comparative_hot_water_efficiency_pct": 59.4, "output_kw_max": 26.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009733", "000048", "0", "2012/Mar/27 10:12", "Grant Engineering", "Grant", "Vortex", "Utility 15-26", "", "2003", "current", "4", "1", "1", "1", "0", "", "", "2", "2", "2", "15", "26", "", "", "89.1", "81.3", "", "59.4", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "93.6", "96.4", "", "", "", "", "95.9"]} +{"pcdb_id": 9734, "brand_name": "Grant", "model_name": "Vortex", "model_qualifier": "Utility System 15-26S", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 81.3, "comparative_hot_water_efficiency_pct": 59.4, "output_kw_max": 26.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009734", "000048", "0", "2012/Mar/27 10:12", "Grant Engineering", "Grant", "Vortex", "Utility System 15-26S", "", "2003", "current", "4", "1", "1", "1", "0", "", "", "2", "2", "2", "15", "26", "", "", "89.1", "81.3", "", "59.4", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "93.6", "96.4", "", "", "", "", "95.9"]} +{"pcdb_id": 9735, "brand_name": "Grant", "model_name": "Vortex", "model_qualifier": "36", "winter_efficiency_pct": 90.5, "summer_efficiency_pct": 82.7, "comparative_hot_water_efficiency_pct": 60.4, "output_kw_max": 36.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009735", "000048", "0", "2012/Mar/27 10:12", "Grant Engineering", "Grant", "Vortex", "36", "", "2003", "current", "4", "1", "1", "1", "0", "", "", "2", "2", "2", "36", "36", "", "", "90.5", "82.7", "", "60.4", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "95.1", "99.3", "", "", "", "", "98.5"]} +{"pcdb_id": 9736, "brand_name": "Grant", "model_name": "Vortex", "model_qualifier": "36S", "winter_efficiency_pct": 90.5, "summer_efficiency_pct": 82.7, "comparative_hot_water_efficiency_pct": 60.4, "output_kw_max": 36.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009736", "000048", "0", "2012/Mar/27 10:12", "Grant Engineering", "Grant", "Vortex", "36S", "", "2003", "current", "4", "1", "1", "1", "0", "", "", "2", "2", "2", "36", "36", "", "", "90.5", "82.7", "", "60.4", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "95.1", "99.3", "", "", "", "", "98.5"]} +{"pcdb_id": 9737, "brand_name": "Ravenheat", "model_name": "Silver Star 24", "model_qualifier": "", "winter_efficiency_pct": 80.5, "summer_efficiency_pct": 70.4, "comparative_hot_water_efficiency_pct": 49.5, "output_kw_max": 24.1, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009737", "000026", "0", "2006/Jan/17 12:31", "Ravenheat", "Ravenheat", "Silver Star 24", "", "", "2003", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "24.1", "24.1", "", "", "80.5", "70.4", "", "49.5", "", "2", "", "", "104", "1", "2", "150", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "83.3", "80.5", "", "", "", "", "81.1"]} +{"pcdb_id": 9738, "brand_name": "Ravenheat", "model_name": "Silver Star 24 LPG", "model_qualifier": "", "winter_efficiency_pct": 82.3, "summer_efficiency_pct": 72.2, "comparative_hot_water_efficiency_pct": 50.8, "output_kw_max": 24.1, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009738", "000026", "0", "2006/Jan/17 12:31", "Ravenheat", "Ravenheat", "Silver Star 24 LPG", "", "", "2003", "current", "2", "2", "1", "2", "0", "", "", "1", "2", "2", "24.1", "24.1", "", "", "82.3", "72.2", "", "50.8", "", "2", "0", "", "104", "1", "2", "150", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "", "", "0004", "", "", "", "", "", "", "", "", "85.1", "82.3", "", "", "", "", "82.9"]} +{"pcdb_id": 9739, "brand_name": "Ravenheat", "model_name": "Silver Star 24T", "model_qualifier": "", "winter_efficiency_pct": 80.5, "summer_efficiency_pct": 70.4, "comparative_hot_water_efficiency_pct": 49.5, "output_kw_max": 24.1, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009739", "000026", "0", "2006/Jan/17 12:31", "Ravenheat", "Ravenheat", "Silver Star 24T", "", "", "2003", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "24.1", "24.1", "", "", "80.5", "70.4", "", "49.5", "", "2", "", "", "104", "1", "2", "150", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "", "", "0004", "", "", "", "", "", "", "", "", "83.3", "80.5", "", "", "", "", "81.1"]} +{"pcdb_id": 9740, "brand_name": "Ravenheat", "model_name": "Silver Star 24T LPG", "model_qualifier": "", "winter_efficiency_pct": 82.3, "summer_efficiency_pct": 72.2, "comparative_hot_water_efficiency_pct": 50.8, "output_kw_max": 24.1, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009740", "000026", "0", "2006/Jan/17 12:31", "Ravenheat", "Ravenheat", "Silver Star 24T LPG", "", "", "2003", "current", "2", "2", "1", "2", "0", "", "", "1", "2", "2", "24.1", "24.1", "", "", "82.3", "72.2", "", "50.8", "", "2", "0", "", "104", "1", "2", "150", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "85.1", "82.3", "", "", "", "", "82.9"]} +{"pcdb_id": 9741, "brand_name": "Ravenheat", "model_name": "Silver Star 29", "model_qualifier": "", "winter_efficiency_pct": 80.5, "summer_efficiency_pct": 70.4, "comparative_hot_water_efficiency_pct": 49.5, "output_kw_max": 29.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009741", "000026", "0", "2006/Jan/17 12:31", "Ravenheat", "Ravenheat", "Silver Star 29", "", "", "2003", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "29.0", "29.0", "", "", "80.5", "70.4", "", "49.5", "", "2", "", "", "104", "1", "2", "150", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "", "", "0004", "", "", "", "", "", "", "", "", "83.3", "80.5", "", "", "", "", "81.1"]} +{"pcdb_id": 9742, "brand_name": "Ravenheat", "model_name": "Silver Star 29 LPG", "model_qualifier": "", "winter_efficiency_pct": 82.3, "summer_efficiency_pct": 72.2, "comparative_hot_water_efficiency_pct": 50.8, "output_kw_max": 29.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009742", "000026", "0", "2006/Jan/17 12:31", "Ravenheat", "Ravenheat", "Silver Star 29 LPG", "", "", "2003", "current", "2", "2", "1", "2", "0", "", "", "1", "2", "2", "29", "29", "", "", "82.3", "72.2", "", "50.8", "", "2", "0", "", "104", "1", "2", "150", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "", "", "0004", "", "", "", "", "", "", "", "", "85.1", "82.3", "", "", "", "", "82.9"]} +{"pcdb_id": 9743, "brand_name": "Ravenheat", "model_name": "Silver Star 29T", "model_qualifier": "", "winter_efficiency_pct": 80.5, "summer_efficiency_pct": 70.4, "comparative_hot_water_efficiency_pct": 49.5, "output_kw_max": 29.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009743", "000026", "0", "2006/Jan/17 12:31", "Ravenheat", "Ravenheat", "Silver Star 29T", "", "", "2003", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "29.0", "29.0", "", "", "80.5", "70.4", "", "49.5", "", "2", "", "", "104", "1", "2", "150", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "", "", "0004", "", "", "", "", "", "", "", "", "83.3", "80.5", "", "", "", "", "81.1"]} +{"pcdb_id": 9744, "brand_name": "Ravenheat", "model_name": "Silver Star 29T LPG", "model_qualifier": "", "winter_efficiency_pct": 82.3, "summer_efficiency_pct": 72.2, "comparative_hot_water_efficiency_pct": 50.8, "output_kw_max": 29.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009744", "000026", "0", "2006/Jan/17 12:31", "Ravenheat", "Ravenheat", "Silver Star 29T LPG", "", "", "2003", "current", "2", "2", "1", "2", "0", "", "", "1", "2", "2", "29.0", "29.0", "", "", "82.3", "72.2", "", "50.8", "", "2", "0", "", "104", "1", "2", "150", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "", "", "0004", "", "", "", "", "", "", "", "", "85.1", "82.3", "", "", "", "", "82.9"]} +{"pcdb_id": 9745, "brand_name": "Ravenheat", "model_name": "White Star 29", "model_qualifier": "", "winter_efficiency_pct": 80.5, "summer_efficiency_pct": 70.4, "comparative_hot_water_efficiency_pct": 49.5, "output_kw_max": 29.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009745", "000026", "0", "2006/Jan/17 12:31", "Ravenheat", "Ravenheat", "White Star 29", "", "", "2003", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "29.0", "29.0", "", "", "80.5", "70.4", "", "49.5", "", "2", "", "", "104", "1", "2", "150", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "", "", "0004", "", "", "", "", "", "", "", "", "83.3", "80.5", "", "", "", "", "81.1"]} +{"pcdb_id": 9746, "brand_name": "Ravenheat", "model_name": "White Star 29 LPG", "model_qualifier": "", "winter_efficiency_pct": 82.3, "summer_efficiency_pct": 72.2, "comparative_hot_water_efficiency_pct": 50.8, "output_kw_max": 29.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009746", "000026", "0", "2006/Jan/17 12:31", "Ravenheat", "Ravenheat", "White Star 29 LPG", "", "", "2003", "current", "2", "2", "1", "2", "0", "", "", "1", "2", "2", "29.0", "29.0", "", "", "82.3", "72.2", "", "50.8", "", "2", "0", "", "104", "1", "2", "150", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "", "", "0004", "", "", "", "", "", "", "", "", "85.1", "82.3", "", "", "", "", "82.9"]} +{"pcdb_id": 9747, "brand_name": "Ravenheat", "model_name": "White Star 29T", "model_qualifier": "", "winter_efficiency_pct": 80.5, "summer_efficiency_pct": 70.4, "comparative_hot_water_efficiency_pct": 49.5, "output_kw_max": 29.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009747", "000026", "0", "2006/Jan/17 12:31", "Ravenheat", "Ravenheat", "White Star 29T", "", "", "2003", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "29", "29", "", "", "80.5", "70.4", "", "49.5", "", "2", "", "", "104", "1", "2", "150", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "", "", "0004", "", "", "", "", "", "", "", "", "83.3", "80.5", "", "", "", "", "81.1"]} +{"pcdb_id": 9748, "brand_name": "Ravenheat", "model_name": "White Star 29T LPG", "model_qualifier": "", "winter_efficiency_pct": 82.3, "summer_efficiency_pct": 72.2, "comparative_hot_water_efficiency_pct": 50.8, "output_kw_max": 29.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009748", "000026", "0", "2006/Jan/17 12:31", "Ravenheat", "Ravenheat", "White Star 29T LPG", "", "", "2003", "current", "2", "2", "1", "2", "0", "", "", "1", "2", "2", "29", "29", "", "", "82.3", "72.2", "", "50.8", "", "2", "0", "", "104", "1", "2", "150", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "", "", "0004", "", "", "", "", "", "", "", "", "85.1", "82.3", "", "", "", "", "82.9"]} +{"pcdb_id": 9749, "brand_name": "Ravenheat", "model_name": "White Star 24", "model_qualifier": "", "winter_efficiency_pct": 80.5, "summer_efficiency_pct": 70.4, "comparative_hot_water_efficiency_pct": 49.5, "output_kw_max": 24.1, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009749", "000026", "0", "2006/Jan/17 12:31", "Ravenheat", "Ravenheat", "White Star 24", "", "", "2003", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "24.1", "24.1", "", "", "80.5", "70.4", "", "49.5", "", "2", "", "", "104", "1", "2", "150", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "", "", "0004", "", "", "", "", "", "", "", "", "83.3", "80.5", "", "", "", "", "81.1"]} +{"pcdb_id": 9750, "brand_name": "Ravenheat", "model_name": "White Star 24 LPG", "model_qualifier": "", "winter_efficiency_pct": 82.3, "summer_efficiency_pct": 72.2, "comparative_hot_water_efficiency_pct": 50.8, "output_kw_max": 24.1, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009750", "000026", "0", "2006/Jan/17 12:31", "Ravenheat", "Ravenheat", "White Star 24 LPG", "", "", "2003", "current", "2", "2", "1", "2", "0", "", "", "1", "2", "2", "24.1", "24.1", "", "", "82.3", "72.2", "", "50.8", "", "2", "0", "", "104", "1", "2", "150", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "", "", "0004", "", "", "", "", "", "", "", "", "85.1", "82.3", "", "", "", "", "82.9"]} +{"pcdb_id": 9751, "brand_name": "Ravenheat", "model_name": "White Star 24T", "model_qualifier": "", "winter_efficiency_pct": 80.5, "summer_efficiency_pct": 70.4, "comparative_hot_water_efficiency_pct": 49.5, "output_kw_max": 24.1, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009751", "000026", "0", "2006/Jan/17 12:31", "Ravenheat", "Ravenheat", "White Star 24T", "", "", "2003", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "24.1", "24.1", "", "", "80.5", "70.4", "", "49.5", "", "2", "", "", "104", "1", "2", "150", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "", "", "0004", "", "", "", "", "", "", "", "", "83.3", "80.5", "", "", "", "", "81.1"]} +{"pcdb_id": 9752, "brand_name": "Ravenheat", "model_name": "White Star 24T LPG", "model_qualifier": "", "winter_efficiency_pct": 82.3, "summer_efficiency_pct": 72.2, "comparative_hot_water_efficiency_pct": 50.8, "output_kw_max": 24.1, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009752", "000026", "0", "2006/Jan/17 12:31", "Ravenheat", "Ravenheat", "White Star 24T LPG", "", "", "2003", "current", "2", "2", "1", "2", "0", "", "", "1", "2", "2", "24.1", "24.1", "", "", "82.3", "72.2", "", "50.8", "", "2", "0", "", "104", "1", "2", "150", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "", "", "0004", "", "", "", "", "", "", "", "", "85.1", "82.3", "", "", "", "", "82.9"]} +{"pcdb_id": 9753, "brand_name": "Ravenheat", "model_name": "HE 85A T LPG", "model_qualifier": "", "winter_efficiency_pct": 90.6, "summer_efficiency_pct": 82.0, "comparative_hot_water_efficiency_pct": 57.6, "output_kw_max": 25.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009753", "000026", "0", "2006/Jan/17 12:31", "Ravenheat", "Ravenheat", "HE 85A T LPG", "", "", "2003", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "25.6", "25.6", "", "", "90.6", "82.0", "", "57.6", "", "2", "0", "", "104", "1", "2", "60", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "0", "", "0005", "", "", "", "", "", "", "", "", "90.9", "100.1", "", "", "", "", "98.4"]} +{"pcdb_id": 9754, "brand_name": "Ravenheat", "model_name": "HE 85A T", "model_qualifier": "", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 56.8, "output_kw_max": 25.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009754", "000026", "0", "2006/Jan/17 12:31", "Ravenheat", "Ravenheat", "HE 85A T", "", "", "2003", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "25.6", "25.6", "", "", "89.4", "80.8", "", "56.8", "", "2", "", "", "104", "1", "2", "60", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "0", "", "0005", "", "", "", "", "", "", "", "", "88.9", "100.0", "", "", "", "", "97.9"]} +{"pcdb_id": 9755, "brand_name": "Ravenheat", "model_name": "HE 85 A LPG", "model_qualifier": "", "winter_efficiency_pct": 90.6, "summer_efficiency_pct": 82.0, "comparative_hot_water_efficiency_pct": 57.6, "output_kw_max": 25.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009755", "000026", "0", "2006/Jan/17 12:31", "Ravenheat", "Ravenheat", "HE 85 A LPG", "", "", "2003", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "25.6", "25.6", "", "", "90.6", "82.0", "", "57.6", "", "2", "0", "", "104", "1", "2", "60", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "0", "", "0005", "", "", "", "", "", "", "", "", "90.9", "100.1", "", "", "", "", "98.4"]} +{"pcdb_id": 9756, "brand_name": "Ravenheat", "model_name": "HE 85 A", "model_qualifier": "", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 56.8, "output_kw_max": 25.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009756", "000026", "0", "2006/Jan/17 12:31", "Ravenheat", "Ravenheat", "HE 85 A", "", "", "2003", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "25.6", "25.6", "", "", "89.4", "80.8", "", "56.8", "", "2", "", "", "104", "1", "2", "60", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "0", "", "0005", "", "", "", "", "", "", "", "", "88.9", "100.0", "", "", "", "", "97.9"]} +{"pcdb_id": 9757, "brand_name": "Ravenheat", "model_name": "HE Primary A LPG", "model_qualifier": "", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 81.6, "comparative_hot_water_efficiency_pct": 59.6, "output_kw_max": 25.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009757", "000026", "0", "2012/Mar/27 10:12", "Ravenheat", "Ravenheat", "HE Primary A LPG", "", "", "2003", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "11.7", "25.6", "", "", "89.2", "81.6", "", "59.6", "", "2", "0", "", "101", "1", "1", "60", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.9", "100.1", "", "", "", "", "98.4"]} +{"pcdb_id": 9758, "brand_name": "Ravenheat", "model_name": "HE Primary A", "model_qualifier": "", "winter_efficiency_pct": 87.2, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 25.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009758", "000026", "0", "2012/Mar/27 10:12", "Ravenheat", "Ravenheat", "HE Primary A", "", "", "2003", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "11.7", "25.6", "", "", "87.2", "79.6", "", "58.2", "", "2", "", "", "101", "1", "1", "60", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "88.9", "98.0", "", "", "", "", "96.3"]} +{"pcdb_id": 9759, "brand_name": "Ravenheat", "model_name": "HE System A LPG", "model_qualifier": "", "winter_efficiency_pct": 90.6, "summer_efficiency_pct": 81.6, "comparative_hot_water_efficiency_pct": 59.6, "output_kw_max": 25.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009759", "000026", "0", "2012/Mar/27 10:12", "Ravenheat", "Ravenheat", "HE System A LPG", "", "", "2003", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "25.6", "25.6", "", "", "90.6", "81.6", "", "59.6", "", "2", "0", "", "102", "1", "2", "60", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.9", "100.1", "", "", "", "", "98.4"]} +{"pcdb_id": 9760, "brand_name": "Ravenheat", "model_name": "HE System A", "model_qualifier": "", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 80.4, "comparative_hot_water_efficiency_pct": 58.7, "output_kw_max": 25.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009760", "000026", "0", "2012/Mar/27 10:12", "Ravenheat", "Ravenheat", "HE System A", "", "", "2003", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "25.6", "25.6", "", "", "89.4", "80.4", "", "58.7", "", "2", "", "", "102", "1", "2", "60", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.9", "100.0", "", "", "", "", "97.9"]} +{"pcdb_id": 9761, "brand_name": "Ravenheat", "model_name": "HE System A T LPG", "model_qualifier": "", "winter_efficiency_pct": 90.6, "summer_efficiency_pct": 81.6, "comparative_hot_water_efficiency_pct": 59.6, "output_kw_max": 25.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009761", "000026", "0", "2012/Mar/27 10:12", "Ravenheat", "Ravenheat", "HE System A T LPG", "", "", "2003", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "25.6", "25.6", "", "", "90.6", "81.6", "", "59.6", "", "2", "0", "", "102", "1", "2", "60", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.9", "100.1", "", "", "", "", "98.4"]} +{"pcdb_id": 9762, "brand_name": "Ravenheat", "model_name": "HE System A T", "model_qualifier": "", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 80.4, "comparative_hot_water_efficiency_pct": 58.7, "output_kw_max": 25.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009762", "000026", "0", "2012/Mar/27 10:12", "Ravenheat", "Ravenheat", "HE System A T", "", "", "2003", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "25.6", "25.6", "", "", "89.4", "80.4", "", "58.7", "", "2", "", "", "102", "1", "2", "60", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.9", "100.0", "", "", "", "", "97.9"]} +{"pcdb_id": 9763, "brand_name": "NST", "model_name": "Sogno ELR", "model_qualifier": "8-30", "winter_efficiency_pct": 83.3, "summer_efficiency_pct": 72.6, "comparative_hot_water_efficiency_pct": 53.0, "output_kw_max": 30.06, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009763", "000216", "0", "2012/Mar/27 10:12", "NST Nvovi Sistemi Termotecnici", "NST", "Sogno ELR", "8-30", "", "2001", "current", "2", "2", "1", "1", "0", "", "", "1", "3", "2", "30.06", "30.06", "", "", "83.3", "72.6", "", "53.0", "", "2", "1", "", "102", "1", "2", "185", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "87.2", "88.0", "", "", "", "", "87.8"]} +{"pcdb_id": 9764, "brand_name": "NST", "model_name": "Sogno ELR", "model_qualifier": "8-30", "winter_efficiency_pct": 83.5, "summer_efficiency_pct": 72.8, "comparative_hot_water_efficiency_pct": 53.2, "output_kw_max": 30.06, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009764", "000216", "0", "2012/Mar/27 10:12", "NST Nvovi Sistemi Termotecnici", "NST", "Sogno ELR", "8-30", "", "2001", "current", "1", "2", "1", "1", "0", "", "", "1", "3", "2", "30.06", "30.06", "", "", "83.5", "72.8", "", "53.2", "", "2", "", "", "102", "1", "2", "185", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "85.3", "86.0", "", "", "", "", "85.9"]} +{"pcdb_id": 9765, "brand_name": "NST", "model_name": "Sogno ELR", "model_qualifier": "8-26", "winter_efficiency_pct": 83.3, "summer_efficiency_pct": 72.6, "comparative_hot_water_efficiency_pct": 53.0, "output_kw_max": 26.73, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009765", "000216", "0", "2012/Mar/27 10:12", "NST Nvovi Sistemi Termotecnici", "NST", "Sogno ELR", "8-26", "", "2001", "current", "2", "2", "1", "1", "0", "", "", "1", "3", "2", "26.73", "26.73", "", "", "83.3", "72.6", "", "53.0", "", "2", "1", "", "102", "1", "2", "185", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "88.2", "87.9", "", "", "", "", "87.9"]} +{"pcdb_id": 9766, "brand_name": "NST", "model_name": "Sogno ELR", "model_qualifier": "8-26", "winter_efficiency_pct": 83.4, "summer_efficiency_pct": 72.7, "comparative_hot_water_efficiency_pct": 53.1, "output_kw_max": 26.73, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009766", "000216", "0", "2012/Mar/27 10:12", "NST Nvovi Sistemi Termotecnici", "NST", "Sogno ELR", "8-26", "", "2001", "current", "1", "2", "1", "1", "0", "", "", "1", "3", "2", "26.73", "26.73", "", "", "83.4", "72.7", "", "53.1", "", "2", "", "", "102", "1", "2", "185", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "86.3", "86.0", "", "", "", "", "86.0"]} +{"pcdb_id": 9767, "brand_name": "NST", "model_name": "Sogno ELR", "model_qualifier": "8-22", "winter_efficiency_pct": 83.3, "summer_efficiency_pct": 72.6, "comparative_hot_water_efficiency_pct": 53.0, "output_kw_max": 22.42, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009767", "000216", "0", "2012/Mar/27 10:12", "NST Nvovi Sistemi Termotecnici", "NST", "Sogno ELR", "8-22", "", "2001", "current", "2", "2", "1", "1", "0", "", "", "1", "3", "2", "22.42", "22.42", "", "", "83.3", "72.6", "", "53.0", "", "2", "1", "", "102", "1", "2", "185", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "88.2", "87.9", "", "", "", "", "87.9"]} +{"pcdb_id": 9768, "brand_name": "NST", "model_name": "Sogno ELR", "model_qualifier": "8-22", "winter_efficiency_pct": 83.4, "summer_efficiency_pct": 72.7, "comparative_hot_water_efficiency_pct": 53.1, "output_kw_max": 22.42, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009768", "000216", "0", "2012/Mar/27 10:12", "NST Nvovi Sistemi Termotecnici", "NST", "Sogno ELR", "8-22", "", "2001", "current", "1", "2", "1", "1", "0", "", "", "1", "3", "2", "22.42", "22.42", "", "", "83.4", "72.7", "", "53.1", "", "2", "", "", "102", "1", "2", "185", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "86.3", "86.0", "", "", "", "", "86.0"]} +{"pcdb_id": 9769, "brand_name": "NST", "model_name": "Sono ELI", "model_qualifier": "8-30", "winter_efficiency_pct": 83.1, "summer_efficiency_pct": 73.0, "comparative_hot_water_efficiency_pct": 51.3, "output_kw_max": 30.06, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009769", "000216", "0", "2006/Jan/17 12:31", "NST Nvovi Sistemi Termotecnici", "NST", "Sono ELI", "8-30", "", "2001", "current", "2", "2", "1", "2", "0", "", "", "1", "3", "2", "30.06", "30.06", "", "", "83.1", "73.0", "", "51.3", "", "2", "1", "", "104", "1", "2", "185", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "87.2", "88.0", "", "", "", "", "87.8"]} +{"pcdb_id": 9770, "brand_name": "NST", "model_name": "Sogno ELI", "model_qualifier": "8-30", "winter_efficiency_pct": 83.3, "summer_efficiency_pct": 73.2, "comparative_hot_water_efficiency_pct": 51.5, "output_kw_max": 30.06, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009770", "000216", "0", "2006/Jan/17 12:31", "NST Nvovi Sistemi Termotecnici", "NST", "Sogno ELI", "8-30", "", "2001", "current", "1", "2", "1", "2", "0", "", "", "1", "3", "2", "30.06", "30.06", "", "", "83.3", "73.2", "", "51.5", "", "2", "", "", "104", "1", "2", "185", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "85.3", "86.0", "", "", "", "", "85.9"]} +{"pcdb_id": 9771, "brand_name": "NST", "model_name": "Sogno ELI", "model_qualifier": "8-26", "winter_efficiency_pct": 83.1, "summer_efficiency_pct": 73.0, "comparative_hot_water_efficiency_pct": 51.3, "output_kw_max": 26.73, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009771", "000216", "0", "2006/Jan/17 12:31", "NST Nvovi Sistemi Termotecnici", "NST", "Sogno ELI", "8-26", "", "2001", "current", "2", "2", "1", "2", "0", "", "", "1", "3", "2", "26.73", "26.73", "", "", "83.1", "73.0", "", "51.3", "", "2", "1", "", "104", "1", "2", "185", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "88.2", "87.9", "", "", "", "", "87.9"]} +{"pcdb_id": 9772, "brand_name": "NST", "model_name": "Sogno ELI", "model_qualifier": "8-26", "winter_efficiency_pct": 83.2, "summer_efficiency_pct": 73.1, "comparative_hot_water_efficiency_pct": 51.4, "output_kw_max": 26.73, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009772", "000216", "0", "2006/Jan/17 12:31", "NST Nvovi Sistemi Termotecnici", "NST", "Sogno ELI", "8-26", "", "2001", "current", "1", "2", "1", "2", "0", "", "", "1", "3", "2", "26.73", "26.73", "", "", "83.2", "73.1", "", "51.4", "", "2", "", "", "104", "1", "2", "185", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "86.3", "86.0", "", "", "", "", "86.0"]} +{"pcdb_id": 9773, "brand_name": "NST", "model_name": "Sogno ELI", "model_qualifier": "8-22", "winter_efficiency_pct": 83.1, "summer_efficiency_pct": 73.0, "comparative_hot_water_efficiency_pct": 51.3, "output_kw_max": 22.42, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009773", "000216", "0", "2006/Jan/17 12:31", "NST Nvovi Sistemi Termotecnici", "NST", "Sogno ELI", "8-22", "", "2001", "current", "2", "2", "1", "2", "0", "", "", "1", "3", "2", "22.42", "22.42", "", "", "83.1", "73.0", "", "51.3", "", "2", "1", "", "104", "1", "2", "185", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "88.2", "87.9", "", "", "", "", "87.9"]} +{"pcdb_id": 9774, "brand_name": "NST", "model_name": "Sogno ELI", "model_qualifier": "8-22", "winter_efficiency_pct": 83.2, "summer_efficiency_pct": 73.1, "comparative_hot_water_efficiency_pct": 51.4, "output_kw_max": 22.42, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009774", "000216", "0", "2006/Jan/17 12:31", "NST Nvovi Sistemi Termotecnici", "NST", "Sogno ELI", "8-22", "", "2001", "current", "1", "2", "1", "2", "0", "", "", "1", "3", "2", "22.42", "22.42", "", "", "83.2", "73.1", "", "51.4", "", "2", "", "", "104", "1", "2", "185", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "86.3", "86.0", "", "", "", "", "86.0"]} +{"pcdb_id": 9775, "brand_name": "Baxi", "model_name": "Combi", "model_qualifier": "Instant 80 e", "winter_efficiency_pct": 79.5, "summer_efficiency_pct": 69.4, "comparative_hot_water_efficiency_pct": 48.8, "output_kw_max": 24.0, "final_year_of_manufacture": 2005, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009775", "000005", "0", "2006/Nov/21 10:07", "Baxi SpA", "Baxi", "Combi", "Instant 80 e", "GC no. 47-075-13", "2003", "2005", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "24.0", "24.0", "", "", "79.5", "69.4", "", "48.8", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.2", "79.2", "", "", "", "", "79.8"]} +{"pcdb_id": 9776, "brand_name": "Baxi Potterton", "model_name": "Baxi Bermuda", "model_qualifier": "Inset 3 50/5", "winter_efficiency_pct": 78.0, "summer_efficiency_pct": 67.3, "comparative_hot_water_efficiency_pct": 49.1, "output_kw_max": 14.65, "final_year_of_manufacture": 2005, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009776", "000005", "0", "2012/Mar/27 10:12", "Baxi Potterton", "Baxi Potterton", "Baxi Bermuda", "Inset 3 50/5", "GC No. 44-075-07", "2003", "2005", "1", "4", "1", "1", "0", "", "", "1", "1", "1", "14.65", "14.65", "", "", "78.0", "67.3", "", "49.1", "", "2", "", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.6", "76.3", "", "", "", "", "77.3"]} +{"pcdb_id": 9777, "brand_name": "Baxi", "model_name": "Bermuda", "model_qualifier": "51/5", "winter_efficiency_pct": 79.0, "summer_efficiency_pct": 68.3, "comparative_hot_water_efficiency_pct": 49.9, "output_kw_max": 15.0, "final_year_of_manufacture": 2010, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009777", "000005", "0", "2012/Mar/27 10:12", "Baxi Potterton", "Baxi", "Bermuda", "51/5", "GC No. 44-075-06", "2003", "2010", "1", "4", "1", "1", "0", "", "", "1", "1", "1", "15", "15", "", "", "79.0", "68.3", "", "49.9", "", "2", "", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "80.7", "79.3", "", "", "", "", "79.6"]} +{"pcdb_id": 9782, "brand_name": "Hermann Srl", "model_name": "Eura 32 SE", "model_qualifier": "", "winter_efficiency_pct": 80.2, "summer_efficiency_pct": 70.1, "comparative_hot_water_efficiency_pct": 49.3, "output_kw_max": 31.7, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009782", "000234", "0", "2013/Jun/25 14:32", "Hermann Srl", "Hermann Srl", "Eura 32 SE", "", "", "2000", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "31.7", "31.7", "", "", "80.2", "70.1", "", "49.3", "", "2", "", "", "104", "1", "2", "185", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.7", "80.1", "", "", "", "", "80.6"]} +{"pcdb_id": 9783, "brand_name": "Hermann Srl", "model_name": "Euromini 24 SE", "model_qualifier": "", "winter_efficiency_pct": 80.8, "summer_efficiency_pct": 70.7, "comparative_hot_water_efficiency_pct": 49.7, "output_kw_max": 23.7, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009783", "000234", "0", "2013/Jun/25 14:33", "Hermann Srl", "Hermann Srl", "Euromini 24 SE", "", "", "2003", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "23.7", "23.7", "", "", "80.8", "70.7", "", "49.7", "", "2", "", "", "104", "1", "2", "150", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "84.2", "81.2", "", "", "", "", "81.7"]} +{"pcdb_id": 9784, "brand_name": "Hermann Srl", "model_name": "Supermicra 24 SE", "model_qualifier": "", "winter_efficiency_pct": 79.6, "summer_efficiency_pct": 69.5, "comparative_hot_water_efficiency_pct": 48.9, "output_kw_max": 23.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009784", "000234", "0", "2013/Jun/25 14:33", "Hermann Srl", "Hermann Srl", "Supermicra 24 SE", "", "", "2002", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "23.6", "23.6", "", "", "79.6", "69.5", "", "48.9", "", "2", "", "", "104", "1", "2", "150", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "83.0", "78.7", "", "", "", "", "79.6"]} +{"pcdb_id": 9785, "brand_name": "Hermann Srl", "model_name": "Supermicra 30 SE", "model_qualifier": "", "winter_efficiency_pct": 80.9, "summer_efficiency_pct": 70.8, "comparative_hot_water_efficiency_pct": 49.8, "output_kw_max": 29.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009785", "000234", "0", "2013/Jun/25 14:33", "Hermann Srl", "Hermann Srl", "Supermicra 30 SE", "", "", "2002", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "29.5", "29.5", "", "", "80.9", "70.8", "", "49.8", "", "2", "", "", "104", "1", "2", "180", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "84.2", "81.4", "", "", "", "", "81.9"]} +{"pcdb_id": 9788, "brand_name": "Sile SpA", "model_name": "Condensa 32 R", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 56.2, "output_kw_max": 30.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009788", "000221", "0", "2008/Sep/29 16:02", "Sile SpA", "Sile SpA", "Condensa 32 R", "", "", "2003", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "30.00", "30.00", "", "", "88.4", "79.8", "", "56.2", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.2", "97.8", "", "", "", "", "96.0"]} +{"pcdb_id": 9789, "brand_name": "Sile SpA", "model_name": "Condensa 50 R", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 56.2, "output_kw_max": 48.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009789", "000221", "0", "2008/Sep/29 16:03", "Sile SpA", "Sile SpA", "Condensa 50 R", "", "", "2003", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "48.00", "48.00", "", "", "88.4", "79.8", "", "56.2", "", "2", "", "", "104", "1", "2", "140", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.2", "97.8", "", "", "", "", "96.0"]} +{"pcdb_id": 9790, "brand_name": "Sile SpA", "model_name": "Condensa 50 N", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 48.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009790", "000221", "0", "2012/Mar/27 10:12", "Sile SpA", "Sile SpA", "Condensa 50 N", "", "", "2003", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "48.00", "48.00", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "140", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.2", "97.8", "", "", "", "", "96.0"]} +{"pcdb_id": 9791, "brand_name": "Sile SpA", "model_name": "Condensa 50 N3V", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 48.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009791", "000221", "0", "2012/Mar/27 10:12", "Sile SpA", "Sile SpA", "Condensa 50 N3V", "", "", "2003", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "48.00", "48.00", "", "", "88.5", "79.5", "", "58.1", "", "2", "", "", "102", "1", "2", "140", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.7", "97.8", "", "", "", "", "96.1"]} +{"pcdb_id": 9792, "brand_name": "Sile SpA", "model_name": "Condensa 50 Maxi", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 81.2, "comparative_hot_water_efficiency_pct": 35.4, "output_kw_max": 48.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009792", "000221", "0", "2024/Jan/31 10:17", "Sile SpA", "Sile SpA", "Condensa 50 Maxi", "", "", "2003", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "48.0", "48.0", "", "", "88.5", "81.2", "", "35.4", "", "2", "", "", "106", "1", "2", "140", "0", "2", "1", "0", "120", "0", "15", "4", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.7", "97.8", "", "", "", "", "96.1"]} +{"pcdb_id": 9793, "brand_name": "Geminox", "model_name": "THI 10-50 C", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 52.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009793", "000212", "0", "2012/Mar/27 10:12", "Geminox", "Geminox", "THI 10-50 C", "", "", "2004", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "52.6", "52.6", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "53", "9.2", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.7", "97.0", "", "", "", "", "95.3"]} +{"pcdb_id": 9794, "brand_name": "Geminox", "model_name": "THI 5-25 M75", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 48.5, "output_kw_max": 23.9, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 1, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009794", "000212", "0", "2024/Jan/31 10:17", "Geminox", "Geminox", "THI 5-25 M75", "", "", "2003", "current", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "23.9", "23.9", "", "", "88.3", "81.0", "", "48.5", "", "2", "", "", "106", "1", "2", "23", "9.2", "1", "1", "0", "83", "0", "50", "2", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "97.8", "", "", "", "", "95.9"]} +{"pcdb_id": 9795, "brand_name": "Geminox", "model_name": "THI 2-13 M75 V", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 54.3, "output_kw_max": 13.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 1, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009795", "000212", "0", "2024/Jan/31 10:17", "Geminox", "Geminox", "THI 2-13 M75 V", "", "", "2004", "current", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "13.5", "13.5", "", "", "88.3", "81.0", "", "54.3", "", "2", "", "", "106", "1", "2", "23", "9.2", "1", "1", "0", "83", "0", "50", "2", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "97.8", "", "", "", "", "95.9"]} +{"pcdb_id": 9796, "brand_name": "Geminox", "model_name": "THI 5-25S", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 49.3, "output_kw_max": 23.9, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 1, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009796", "000212", "0", "2024/Jan/31 10:17", "Geminox", "Geminox", "THI 5-25S", "", "", "2004", "current", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "23.9", "23.9", "", "", "88.3", "81.0", "", "49.3", "", "2", "", "", "106", "1", "2", "23", "9.2", "1", "1", "0", "24.5", "0", "35", "2", "60", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "97.8", "", "", "", "", "95.9"]} +{"pcdb_id": 9797, "brand_name": "Geminox", "model_name": "THI 5-25 SEP", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 62.2, "output_kw_max": 23.9, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009797", "000212", "0", "2006/Mar/29 12:43", "Geminox", "Geminox", "THI 5-25 SEP", "", "", "2003", "current", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "23.9", "23.9", "", "", "88.3", "79.7", "", "62.2", "", "2", "", "", "104", "1", "2", "23", "9.2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "", "0005", "", "", "", "", "", "", "", "", "87.8", "97.8", "", "", "", "", "95.9"]} +{"pcdb_id": 9798, "brand_name": "Geminox", "model_name": "THI 5-25 C", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 23.9, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009798", "000212", "0", "2012/Mar/27 10:12", "Geminox", "Geminox", "THI 5-25 C", "", "", "2004", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "23.9", "23.9", "", "", "88.3", "79.3", "", "58.0", "", "2", "", "", "102", "1", "2", "23", "9.2", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "97.8", "", "", "", "", "95.9"]} +{"pcdb_id": 9799, "brand_name": "Geminox", "model_name": "THI 2-13 C", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 13.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009799", "000212", "0", "2012/Mar/27 10:12", "Geminox", "Geminox", "THI 2-13 C", "", "", "2003", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "13.5", "13.5", "", "", "88.3", "79.3", "", "58.0", "", "2", "", "", "102", "1", "2", "23", "9.2", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "97.8", "", "", "", "", "95.9"]} +{"pcdb_id": 9800, "brand_name": "Geminox", "model_name": "THI 0.9-9 C", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 9.1, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009800", "000212", "0", "2012/Mar/27 10:12", "Geminox", "Geminox", "THI 0.9-9 C", "", "", "2003", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "9.1", "9.1", "", "", "88.3", "79.3", "", "58.0", "", "2", "", "", "102", "1", "2", "23", "9.2", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "97.8", "", "", "", "", "95.9"]} +{"pcdb_id": 9801, "brand_name": "Ideal", "model_name": "Mini C32", "model_qualifier": "32kW Combi Boiler", "winter_efficiency_pct": 79.2, "summer_efficiency_pct": 69.1, "comparative_hot_water_efficiency_pct": 48.6, "output_kw_max": 32.0, "final_year_of_manufacture": 2004, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009801", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "Mini C32", "32kW Combi Boiler", "0694BM3420", "2003", "2004", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "32.0", "32.0", "", "", "79.2", "69.1", "", "48.6", "", "2", "", "", "104", "1", "2", "180", "7", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.0", "78.7", "", "", "", "", "79.4"]} +{"pcdb_id": 9802, "brand_name": "Alpha", "model_name": "C27", "model_qualifier": "", "winter_efficiency_pct": 79.8, "summer_efficiency_pct": 69.7, "comparative_hot_water_efficiency_pct": 49.0, "output_kw_max": 27.0, "final_year_of_manufacture": 2005, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009802", "000001", "0", "2006/Jan/17 12:31", "Alpha Therm", "Alpha", "C27", "", "", "2003", "2005", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "27", "27", "", "", "79.8", "69.7", "", "49.0", "", "2", "", "", "104", "1", "2", "170", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.8", "80.3", "", "", "", "", "80.6"]} +{"pcdb_id": 9803, "brand_name": "Alpha", "model_name": "C23", "model_qualifier": "", "winter_efficiency_pct": 79.8, "summer_efficiency_pct": 69.7, "comparative_hot_water_efficiency_pct": 49.0, "output_kw_max": 23.3, "final_year_of_manufacture": 2005, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009803", "000001", "0", "2011/Sep/06 13:07", "Alpha Therm", "Alpha", "C23", "", "", "2003", "2005", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "23.3", "23.3", "", "", "79.8", "69.7", "", "49.0", "", "2", "", "", "104", "1", "2", "170", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.6", "80.5", "", "", "", "", "80.7"]} +{"pcdb_id": 9804, "brand_name": "IRSAP", "model_name": "Ecogreen CWAI 24", "model_qualifier": "M", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 55.8, "output_kw_max": 24.12, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009804", "000235", "0", "2006/Jan/17 12:31", "IRSAP", "IRSAP", "Ecogreen CWAI 24", "M", "", "2002", "current", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "24.12", "24.12", "", "", "87.9", "79.3", "", "55.8", "", "2", "", "", "104", "1", "2", "37.0", "8.3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.5", "96.4", "", "", "", "", "94.9"]} +{"pcdb_id": 9805, "brand_name": "IRSAP", "model_name": "CWAI 24", "model_qualifier": "M", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 55.8, "output_kw_max": 24.12, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009805", "000235", "0", "2006/Jan/17 12:31", "IRSAP", "IRSAP", "CWAI 24", "M", "", "2002", "current", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "24.12", "24.12", "", "", "87.9", "79.3", "", "55.8", "", "2", "", "", "104", "1", "2", "37.0", "8.3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.5", "96.4", "", "", "", "", "94.9"]} +{"pcdb_id": 9806, "brand_name": "IRSAP", "model_name": "Ecogreen CWAI 32", "model_qualifier": "M", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 56.0, "output_kw_max": 32.02, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009806", "000235", "0", "2006/Jan/17 12:31", "IRSAP", "IRSAP", "Ecogreen CWAI 32", "M", "", "2002", "current", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "32.02", "32.02", "", "", "88.2", "79.6", "", "56.0", "", "2", "", "", "104", "1", "2", "47", "8.3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.4", "97.2", "", "", "", "", "95.5"]} +{"pcdb_id": 9807, "brand_name": "IRSAP", "model_name": "CWAI 32", "model_qualifier": "M", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 56.0, "output_kw_max": 32.02, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009807", "000235", "0", "2006/Jan/17 12:31", "IRSAP", "IRSAP", "CWAI 32", "M", "", "2002", "current", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "32.02", "32.02", "", "", "88.2", "79.6", "", "56.0", "", "2", "", "", "104", "1", "2", "47", "8.3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.4", "97.2", "", "", "", "", "95.5"]} +{"pcdb_id": 9808, "brand_name": "IRSAP", "model_name": "Ecogreen CWAS 24", "model_qualifier": "M", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 80.6, "comparative_hot_water_efficiency_pct": 46.5, "output_kw_max": 24.12, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009808", "000235", "0", "2024/Jan/31 10:17", "IRSAP", "IRSAP", "Ecogreen CWAS 24", "M", "", "2002", "current", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "24.12", "24.12", "", "", "87.9", "80.6", "", "46.5", "", "2", "", "", "106", "1", "2", "37.0", "8.3", "2", "1", "0", "55", "0", "20", "2", "55", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.5", "96.4", "", "", "", "", "94.9"]} +{"pcdb_id": 9809, "brand_name": "IRSAP", "model_name": "CWAS 24", "model_qualifier": "M", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 80.6, "comparative_hot_water_efficiency_pct": 46.5, "output_kw_max": 24.12, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009809", "000235", "0", "2024/Jan/31 10:17", "IRSAP", "IRSAP", "CWAS 24", "M", "", "2002", "current", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "24.12", "24.12", "", "", "87.9", "80.6", "", "46.5", "", "2", "", "", "106", "1", "2", "37.0", "8.3", "2", "1", "0", "55", "0", "20", "2", "55", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.5", "96.4", "", "", "", "", "94.9"]} +{"pcdb_id": 9810, "brand_name": "IRSAP", "model_name": "Ecogreen CWAS 32", "model_qualifier": "M", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 80.9, "comparative_hot_water_efficiency_pct": 46.6, "output_kw_max": 32.02, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009810", "000235", "0", "2024/Jan/31 10:17", "IRSAP", "IRSAP", "Ecogreen CWAS 32", "M", "", "2002", "current", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "32.02", "32.02", "", "", "88.2", "80.9", "", "46.6", "", "2", "", "", "106", "1", "2", "47", "8.3", "2", "1", "0", "55", "0", "20", "2", "55", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.4", "97.2", "", "", "", "", "95.5"]} +{"pcdb_id": 9811, "brand_name": "IRSAP", "model_name": "CWAS 32", "model_qualifier": "M", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 80.9, "comparative_hot_water_efficiency_pct": 46.6, "output_kw_max": 32.02, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009811", "000235", "0", "2024/Jan/31 10:17", "IRSAP", "IRSAP", "CWAS 32", "M", "", "2002", "current", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "32.02", "32.02", "", "", "88.2", "80.9", "", "46.6", "", "2", "", "", "106", "1", "2", "47", "8.3", "2", "1", "0", "55", "0", "20", "2", "55", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.4", "97.2", "", "", "", "", "95.5"]} +{"pcdb_id": 9812, "brand_name": "Vokera", "model_name": "Syntesi", "model_qualifier": "35 LPG", "winter_efficiency_pct": 89.3, "summer_efficiency_pct": 80.7, "comparative_hot_water_efficiency_pct": 56.7, "output_kw_max": 33.9, "final_year_of_manufacture": 2010, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009812", "000011", "0", "2010/Oct/21 11:07", "Vokera", "Vokera", "Syntesi", "35 LPG", "4709451", "2003", "2010", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "33.9", "33.9", "", "", "89.3", "80.7", "", "56.7", "", "2", "0", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.7", "97.2", "", "", "", "", "95.7"]} +{"pcdb_id": 9813, "brand_name": "Vokera", "model_name": "Syntesi", "model_qualifier": "35", "winter_efficiency_pct": 86.4, "summer_efficiency_pct": 77.8, "comparative_hot_water_efficiency_pct": 54.7, "output_kw_max": 33.9, "final_year_of_manufacture": 2010, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009813", "000011", "0", "2010/Oct/21 11:08", "Vokera", "Vokera", "Syntesi", "35", "470945", "2003", "2010", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "33.9", "33.9", "", "", "86.4", "77.8", "", "54.7", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.3", "93.1", "", "", "", "", "92.0"]} +{"pcdb_id": 9814, "brand_name": "Vokera", "model_name": "Syntesi", "model_qualifier": "29 LPG", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 56.2, "output_kw_max": 28.0, "final_year_of_manufacture": 2010, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009814", "000011", "0", "2010/Oct/21 11:08", "Vokera", "Vokera", "Syntesi", "29 LPG", "4709449", "2003", "2010", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "28.0", "28.0", "", "", "88.6", "80.0", "", "56.2", "", "2", "0", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.5", "95.4", "", "", "", "", "94.3"]} +{"pcdb_id": 9815, "brand_name": "Vokera", "model_name": "Syntesi", "model_qualifier": "29", "winter_efficiency_pct": 86.0, "summer_efficiency_pct": 77.4, "comparative_hot_water_efficiency_pct": 54.4, "output_kw_max": 28.0, "final_year_of_manufacture": 2010, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009815", "000011", "0", "2010/Oct/21 11:08", "Vokera", "Vokera", "Syntesi", "29", "4709448", "2003", "2010", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28.0", "28.0", "", "", "86.0", "77.4", "", "54.4", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.0", "92.1", "", "", "", "", "91.1"]} +{"pcdb_id": 9816, "brand_name": "Vokera", "model_name": "Syntesi", "model_qualifier": "25 LPG", "winter_efficiency_pct": 89.5, "summer_efficiency_pct": 80.9, "comparative_hot_water_efficiency_pct": 56.9, "output_kw_max": 24.1, "final_year_of_manufacture": 2010, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009816", "000011", "0", "2010/Oct/21 11:08", "Vokera", "Vokera", "Syntesi", "25 LPG", "4709447", "2003", "2010", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24.1", "24.1", "", "", "89.5", "80.9", "", "56.9", "", "2", "0", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.2", "97.6", "", "", "", "", "96.2"]} +{"pcdb_id": 9817, "brand_name": "Vokera", "model_name": "Syntesi", "model_qualifier": "25", "winter_efficiency_pct": 86.0, "summer_efficiency_pct": 77.4, "comparative_hot_water_efficiency_pct": 54.4, "output_kw_max": 24.1, "final_year_of_manufacture": 2010, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009817", "000011", "0", "2010/Oct/21 11:08", "Vokera", "Vokera", "Syntesi", "25", "4709446", "2003", "2010", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.1", "24.1", "", "", "86.0", "77.4", "", "54.4", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "86.8", "92.2", "", "", "", "", "91.1"]} +{"pcdb_id": 9818, "brand_name": "Vokera", "model_name": "Synergy", "model_qualifier": "29 LPG", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 28.0, "final_year_of_manufacture": 2010, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009818", "000011", "0", "2012/Mar/27 10:12", "Vokera", "Vokera", "Synergy", "29 LPG", "4109428", "2003", "2010", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "28.0", "28.0", "", "", "88.6", "79.6", "", "58.1", "", "2", "0", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.5", "95.4", "", "", "", "", "94.3"]} +{"pcdb_id": 9819, "brand_name": "Vokera", "model_name": "Synergy", "model_qualifier": "29", "winter_efficiency_pct": 86.0, "summer_efficiency_pct": 77.0, "comparative_hot_water_efficiency_pct": 56.2, "output_kw_max": 28.0, "final_year_of_manufacture": 2010, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009819", "000011", "0", "2012/Mar/27 10:12", "Vokera", "Vokera", "Synergy", "29", "4109427", "2003", "2010", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "28.0", "28.0", "", "", "86.0", "77.0", "", "56.2", "", "2", "", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.0", "92.1", "", "", "", "", "91.1"]} +{"pcdb_id": 9825, "brand_name": "Atlantic 2000", "model_name": "R22/22", "model_qualifier": "Oil", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 80.4, "comparative_hot_water_efficiency_pct": 58.7, "output_kw_max": 22.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009825", "000003", "0", "2023/Apr/27 08:50", "RYLL HEIZUNGS GMBH", "Atlantic 2000", "R22/22", "Oil", "", "2000", "obsolete", "4", "1", "1", "1", "0", "", "", "2", "1", "2", "15", "22.0", "", "", "88.2", "80.4", "", "58.7", "", "2", "", "", "201", "1", "1", "273", "15", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "95.0", "93.5", "", "", "", "", "93.8"]} +{"pcdb_id": 9826, "brand_name": "Atlantic 2000", "model_name": "R22/40", "model_qualifier": "Oil", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 58.8, "output_kw_max": 40.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009826", "000003", "0", "2023/Apr/27 08:50", "RYLL HEIZUNGS GMBH", "Atlantic 2000", "R22/40", "Oil", "2297E 06030255", "2000", "obsolete", "4", "1", "1", "1", "0", "", "", "2", "1", "2", "28", "40", "", "", "88.3", "80.5", "", "58.8", "", "2", "", "", "201", "1", "1", "375", "15", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "95.3", "93.7", "", "", "", "", "94.0"]} +{"pcdb_id": 9830, "brand_name": "Keston", "model_name": "C", "model_qualifier": "40P", "winter_efficiency_pct": 89.6, "summer_efficiency_pct": 80.6, "comparative_hot_water_efficiency_pct": 58.9, "output_kw_max": 39.1, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009830", "000022", "0", "2012/Mar/27 10:12", "Keston Boilers", "Keston", "C", "40P", "41-930-08", "2002", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "39.1", "39.1", "", "", "89.6", "80.6", "", "58.9", "", "2", "1", "", "102", "1", "2", "260", "8", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.4", "100.2", "", "", "", "", "98.3"]} +{"pcdb_id": 9831, "brand_name": "Keston", "model_name": "C", "model_qualifier": "55P", "winter_efficiency_pct": 90.1, "summer_efficiency_pct": 81.1, "comparative_hot_water_efficiency_pct": 59.2, "output_kw_max": 48.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009831", "000022", "0", "2012/Mar/27 10:12", "Keston Boilers", "Keston", "C", "55P", "41-930-10", "2002", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "48.2", "48.2", "", "", "90.1", "81.1", "", "59.2", "", "2", "1", "", "102", "1", "2", "260", "8", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.9", "101.7", "", "", "", "", "99.4"]} +{"pcdb_id": 9832, "brand_name": "Halstead", "model_name": "Finest Platinum", "model_qualifier": "", "winter_efficiency_pct": 79.6, "summer_efficiency_pct": 69.5, "comparative_hot_water_efficiency_pct": 54.2, "output_kw_max": 24.9, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009832", "000019", "0", "2006/Jan/17 12:31", "Halstead Boilers", "Halstead", "Finest Platinum", "", "", "2003", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "24.9", "24.9", "", "", "79.6", "69.5", "", "54.2", "", "2", "", "", "104", "1", "2", "190", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "", "0004", "", "", "", "", "", "", "", "", "81.5", "80.1", "", "", "", "", "80.4"]} +{"pcdb_id": 9833, "brand_name": "Mistral", "model_name": "CKUT2 - 7090", "model_qualifier": "Kitchen Utility", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 26.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009833", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "CKUT2 - 7090", "Kitchen Utility", "", "2003", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "20.5", "26.3", "", "", "87.9", "80.1", "", "58.5", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.4", "94.6", "", "", "", "", "93.8"]} +{"pcdb_id": 9834, "brand_name": "Mistral", "model_name": "CKUT1 - 5070", "model_qualifier": "Kitchen Utility", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 20.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009834", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "CKUT1 - 5070", "Kitchen Utility", "", "2003", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "14.6", "20.5", "", "", "87.9", "80.1", "", "58.5", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.4", "94.6", "", "", "", "", "93.8"]} +{"pcdb_id": 9835, "brand_name": "Mistral", "model_name": "CC2 - 7090", "model_qualifier": "Condensing Combi", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 81.8, "comparative_hot_water_efficiency_pct": 49.2, "output_kw_max": 26.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009835", "000056", "0", "2024/Jan/31 10:17", "Mistral Boilers", "Mistral", "CC2 - 7090", "Condensing Combi", "", "2003", "current", "4", "1", "1", "2", "0", "", "", "2", "3", "1", "20.5", "26.3", "", "", "87.9", "81.8", "", "49.2", "", "2", "", "", "203", "1", "1", "", "", "2", "", "0", "60", "0", "25", "3", "75", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.4", "94.6", "", "", "", "", "93.8"]} +{"pcdb_id": 9836, "brand_name": "Mistral", "model_name": "CC1 - 5070", "model_qualifier": "Condensing Combi", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 81.8, "comparative_hot_water_efficiency_pct": 49.2, "output_kw_max": 20.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009836", "000056", "0", "2024/Jan/31 10:17", "Mistral Boilers", "Mistral", "CC1 - 5070", "Condensing Combi", "", "2003", "current", "4", "1", "1", "2", "0", "", "", "2", "3", "1", "14.6", "20.5", "", "", "87.9", "81.8", "", "49.2", "", "2", "", "", "203", "1", "1", "", "", "2", "", "0", "60", "0", "25", "3", "75", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.4", "94.6", "", "", "", "", "93.8"]} +{"pcdb_id": 9837, "brand_name": "Mistral", "model_name": "CK2 - 7090", "model_qualifier": "Kitchen", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 26.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009837", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "CK2 - 7090", "Kitchen", "", "2003", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "20.5", "26.3", "", "", "87.9", "80.1", "", "58.5", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.4", "94.6", "", "", "", "", "93.8"]} +{"pcdb_id": 9838, "brand_name": "Mistral", "model_name": "CK1 - 5070", "model_qualifier": "Kitchen", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 20.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009838", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "CK1 - 5070", "Kitchen", "", "2003", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "14.6", "20.5", "", "", "87.9", "80.1", "", "58.5", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.4", "94.6", "", "", "", "", "93.8"]} +{"pcdb_id": 9839, "brand_name": "Mistral", "model_name": "CS2 - 7090", "model_qualifier": "Sealed System", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 26.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009839", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "CS2 - 7090", "Sealed System", "", "2003", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "20.5", "26.3", "", "", "87.9", "80.1", "", "58.5", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.4", "94.6", "", "", "", "", "93.8"]} +{"pcdb_id": 9840, "brand_name": "Mistral", "model_name": "CS1 - 5070", "model_qualifier": "Sealed System", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 20.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009840", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "CS1 - 5070", "Sealed System", "", "2003", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "14.6", "20.5", "", "", "87.9", "80.1", "", "58.5", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.4", "94.6", "", "", "", "", "93.8"]} +{"pcdb_id": 9841, "brand_name": "Mistral", "model_name": "CBH - 7090", "model_qualifier": "Boiler House", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 26.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009841", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "CBH - 7090", "Boiler House", "", "2003", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "20.5", "26.3", "", "", "87.9", "80.1", "", "58.5", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.4", "94.6", "", "", "", "", "93.8"]} +{"pcdb_id": 9842, "brand_name": "Mistral", "model_name": "CBH - 5070", "model_qualifier": "Boiler House", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 20.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009842", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "CBH - 5070", "Boiler House", "", "2003", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "14.6", "20.5", "", "", "87.9", "80.1", "", "58.5", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.4", "94.6", "", "", "", "", "93.8"]} +{"pcdb_id": 9843, "brand_name": "Mistral", "model_name": "COD - 7090", "model_qualifier": "Outdoor Model", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 26.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009843", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "COD - 7090", "Outdoor Model", "", "2003", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "20.5", "26.3", "", "", "87.9", "80.1", "", "58.5", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.4", "94.6", "", "", "", "", "93.8"]} +{"pcdb_id": 9844, "brand_name": "Mistral", "model_name": "COD - 5070", "model_qualifier": "Outdoor Model", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 20.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009844", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "COD - 5070", "Outdoor Model", "", "2003", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "14.6", "20.5", "", "", "87.9", "80.1", "", "58.5", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.4", "94.6", "", "", "", "", "93.8"]} +{"pcdb_id": 9845, "brand_name": "Mistral", "model_name": "COD - SS - 7090", "model_qualifier": "Outdoor Sealed System", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 26.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009845", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "COD - SS - 7090", "Outdoor Sealed System", "", "2003", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "20.5", "26.3", "", "", "87.9", "80.1", "", "58.5", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.4", "94.6", "", "", "", "", "93.8"]} +{"pcdb_id": 9846, "brand_name": "Mistral", "model_name": "COD - SS - 5070", "model_qualifier": "Outdoor Sealed System", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 20.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009846", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "COD - SS - 5070", "Outdoor Sealed System", "", "2003", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "14.6", "20.5", "", "", "87.9", "80.1", "", "58.5", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.4", "94.6", "", "", "", "", "93.8"]} +{"pcdb_id": 9847, "brand_name": "Mistral", "model_name": "COD - C - 7090", "model_qualifier": "Outdoor Combi", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 81.8, "comparative_hot_water_efficiency_pct": 49.2, "output_kw_max": 26.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009847", "000056", "0", "2024/Jan/31 10:17", "Mistral Boilers", "Mistral", "COD - C - 7090", "Outdoor Combi", "", "2003", "current", "4", "1", "1", "2", "0", "", "", "2", "3", "1", "20.5", "26.3", "", "", "87.9", "81.8", "", "49.2", "", "2", "", "", "203", "1", "1", "", "", "2", "", "0", "60", "0", "25", "3", "75", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.4", "94.6", "", "", "", "", "93.8"]} +{"pcdb_id": 9848, "brand_name": "Mistral", "model_name": "COD - C - 5070", "model_qualifier": "Outdoor Combi", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 81.8, "comparative_hot_water_efficiency_pct": 49.2, "output_kw_max": 20.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009848", "000056", "0", "2024/Jan/31 10:17", "Mistral Boilers", "Mistral", "COD - C - 5070", "Outdoor Combi", "", "2003", "current", "4", "1", "1", "2", "0", "", "", "2", "3", "1", "14.6", "20.5", "", "", "87.9", "81.8", "", "49.2", "", "2", "", "", "203", "1", "1", "", "", "2", "", "0", "60", "0", "25", "3", "75", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.4", "94.6", "", "", "", "", "93.8"]} +{"pcdb_id": 9849, "brand_name": "Worcester", "model_name": "Danesmoor FS", "model_qualifier": "12-18", "winter_efficiency_pct": 85.8, "summer_efficiency_pct": 74.1, "comparative_hot_water_efficiency_pct": 54.1, "output_kw_max": 18.0, "final_year_of_manufacture": 2008, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009849", "000035", "0", "2020/Sep/04 08:06", "Worcester Heat Systems", "Worcester", "Danesmoor FS", "12-18", "", "2003", "2008", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "12", "18", "", "", "85.8", "74.1", "", "54.1", "", "2", "", "", "201", "1", "1", "140", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.7", "85.4", "", "", "", "", "85.6"]} +{"pcdb_id": 9850, "brand_name": "Worcester", "model_name": "Danesmoor FS", "model_qualifier": "18-25", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 25.0, "final_year_of_manufacture": 2008, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009850", "000035", "0", "2020/Sep/04 08:06", "Worcester Heat Systems", "Worcester", "Danesmoor FS", "18-25", "", "2003", "2008", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "18", "25", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "140", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.8", "87.7", "", "", "", "", "87.7"]} +{"pcdb_id": 9851, "brand_name": "Halstead", "model_name": "Finest Platinum", "model_qualifier": "", "winter_efficiency_pct": 81.4, "summer_efficiency_pct": 71.3, "comparative_hot_water_efficiency_pct": 50.1, "output_kw_max": 24.9, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009851", "000019", "0", "2006/Jan/17 12:31", "Halstead Boilers", "Halstead", "Finest Platinum", "", "", "2003", "current", "2", "2", "1", "2", "0", "", "", "1", "2", "2", "24.9", "24.9", "", "", "81.4", "71.3", "", "50.1", "", "2", "1", "", "104", "1", "2", "190", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "83.3", "81.9", "", "", "", "", "82.1"]} +{"pcdb_id": 9852, "brand_name": "Glow-worm", "model_name": "38hxi", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 38.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009852", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "38hxi", "", "GC 47-047-71", "2003", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "38.00", "38.00", "", "", "88.5", "79.5", "", "58.1", "", "2", "", "", "102", "1", "2", "60", "15", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0085", "", "", "", "", "", "", "", "", "89.3", "97.5", "", "", "", "", "95.9"]} +{"pcdb_id": 9853, "brand_name": "Ariston", "model_name": "Microcombi 27 MFFI", "model_qualifier": "Micro Combi Series", "winter_efficiency_pct": 80.3, "summer_efficiency_pct": 70.2, "comparative_hot_water_efficiency_pct": 49.3, "output_kw_max": 27.0, "final_year_of_manufacture": 2007, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009853", "000080", "0", "2007/Jun/18 09:32", "Merloni TermoSanitari SpA", "Ariston", "Microcombi 27 MFFI", "Micro Combi Series", "GC No. 47-116-24", "2003", "2007", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "27", "27", "", "", "80.3", "70.2", "", "49.3", "", "2", "", "", "104", "1", "2", "130", "7", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.9", "80.0", "", "", "", "", "80.6"]} +{"pcdb_id": 9854, "brand_name": "Ariston", "model_name": "Microcombi 27 MFFI", "model_qualifier": "MK2", "winter_efficiency_pct": 82.1, "summer_efficiency_pct": 72.0, "comparative_hot_water_efficiency_pct": 50.6, "output_kw_max": 27.0, "final_year_of_manufacture": 2007, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009854", "000080", "0", "2007/Sep/12 15:12", "Merloni TermoSanitari SpA", "Ariston", "Microcombi 27 MFFI", "MK2", "GC No. 47-116-24", "2003", "2007", "2", "2", "1", "2", "0", "", "", "1", "2", "2", "27", "27", "", "", "82.1", "72.0", "", "50.6", "", "2", "1", "", "104", "1", "2", "130", "7", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "84.7", "81.8", "", "", "", "", "82.3"]} +{"pcdb_id": 9859, "brand_name": "Malvern", "model_name": "Dbi Combi", "model_qualifier": "NG", "winter_efficiency_pct": 85.6, "summer_efficiency_pct": 77.0, "comparative_hot_water_efficiency_pct": 54.2, "output_kw_max": 23.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009859", "000023", "0", "2006/Jan/17 12:31", "Malvern Boilers", "Malvern", "Dbi Combi", "NG", "", "2003", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "23.5", "23.5", "", "", "85.6", "77.0", "", "54.2", "", "2", "", "", "104", "1", "2", "120", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.2", "91.1", "", "", "", "", "90.4"]} +{"pcdb_id": 9860, "brand_name": "Servowarm", "model_name": "Elite 21 Condensing Combination", "model_qualifier": "", "winter_efficiency_pct": 85.6, "summer_efficiency_pct": 77.0, "comparative_hot_water_efficiency_pct": 54.2, "output_kw_max": 23.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009860", "000091", "0", "2006/Jan/17 12:31", "Malvern Boilers", "Servowarm", "Elite 21 Condensing Combination", "", "", "2003", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "23.5", "23.5", "", "", "85.6", "77.0", "", "54.2", "", "2", "", "", "104", "1", "2", "120", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.2", "91.1", "", "", "", "", "90.4"]} +{"pcdb_id": 9861, "brand_name": "Warmworld", "model_name": "FFC Combi", "model_qualifier": "", "winter_efficiency_pct": 85.6, "summer_efficiency_pct": 77.0, "comparative_hot_water_efficiency_pct": 54.2, "output_kw_max": 23.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009861", "000034", "0", "2006/Jan/31 12:06", "Warmworld", "Warmworld", "FFC Combi", "", "", "2003", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "23.5", "23.5", "", "", "85.6", "77.0", "", "54.2", "", "2", "", "", "104", "1", "2", "120", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.2", "91.1", "", "", "", "", "90.4"]} +{"pcdb_id": 9862, "brand_name": "Malvern", "model_name": "Dbi Combi", "model_qualifier": "", "winter_efficiency_pct": 86.6, "summer_efficiency_pct": 78.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 23.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009862", "000023", "0", "2006/Jan/17 12:31", "Malvern Boilers", "Malvern", "Dbi Combi", "", "", "2003", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "23.5", "23.5", "", "", "86.6", "78.0", "", "54.8", "", "2", "1", "", "104", "1", "2", "120", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.2", "93.1", "", "", "", "", "92.4"]} +{"pcdb_id": 9863, "brand_name": "Servowarm", "model_name": "Elite 21 Condensing Combination", "model_qualifier": "", "winter_efficiency_pct": 86.6, "summer_efficiency_pct": 78.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 23.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009863", "000091", "0", "2006/Jan/17 12:31", "Malvern Boilers", "Servowarm", "Elite 21 Condensing Combination", "", "", "2003", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "23.5", "23.5", "", "", "86.6", "78.0", "", "54.8", "", "2", "1", "", "104", "1", "2", "120", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.2", "93.1", "", "", "", "", "92.4"]} +{"pcdb_id": 9864, "brand_name": "Warmworld", "model_name": "FFC Combi", "model_qualifier": "", "winter_efficiency_pct": 86.6, "summer_efficiency_pct": 78.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 23.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009864", "000034", "0", "2006/Jan/31 12:05", "Warmworld", "Warmworld", "FFC Combi", "", "", "2003", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "23.5", "23.5", "", "", "86.6", "78.0", "", "54.8", "", "2", "1", "", "104", "1", "2", "120", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.2", "93.1", "", "", "", "", "92.4"]} +{"pcdb_id": 9866, "brand_name": "ICI Caldaie", "model_name": "Solar", "model_qualifier": "System 28F", "winter_efficiency_pct": 81.2, "summer_efficiency_pct": 70.5, "comparative_hot_water_efficiency_pct": 51.5, "output_kw_max": 29.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009866", "000077", "0", "2012/Mar/27 10:12", "ICI Caldaie", "ICI Caldaie", "Solar", "System 28F", "", "2003", "current", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "29.3", "29.3", "", "", "81.2", "70.5", "", "51.5", "", "2", "", "", "102", "1", "2", "10", "120", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "83.8", "81.5", "", "", "", "", "82.0"]} +{"pcdb_id": 9868, "brand_name": "ICI Caldaie", "model_name": "Solar", "model_qualifier": "Micro 28F", "winter_efficiency_pct": 81.0, "summer_efficiency_pct": 70.9, "comparative_hot_water_efficiency_pct": 49.9, "output_kw_max": 29.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009868", "000077", "0", "2003/Oct/30 16:45", "ICI Caldaie", "ICI Caldaie", "Solar", "Micro 28F", "", "2003", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "29.3", "29.3", "", "", "81.0", "70.9", "", "49.9", "", "2", "", "", "104", "1", "2", "10", "120", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "83.8", "81.5", "", "", "", "", "82.0"]} +{"pcdb_id": 9869, "brand_name": "ICI Caldaie", "model_name": "Solar", "model_qualifier": "System 24F", "winter_efficiency_pct": 81.4, "summer_efficiency_pct": 70.7, "comparative_hot_water_efficiency_pct": 51.6, "output_kw_max": 25.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009869", "000077", "0", "2012/Mar/27 10:12", "ICI Caldaie", "ICI Caldaie", "Solar", "System 24F", "", "2003", "current", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "25.3", "25.3", "", "", "81.4", "70.7", "", "51.6", "", "2", "", "", "102", "1", "2", "10", "120", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "84.3", "81.8", "", "", "", "", "82.3"]} +{"pcdb_id": 9870, "brand_name": "ICI Caldaie", "model_name": "Solar", "model_qualifier": "Micro 24F", "winter_efficiency_pct": 81.2, "summer_efficiency_pct": 71.1, "comparative_hot_water_efficiency_pct": 50.0, "output_kw_max": 25.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009870", "000077", "0", "2003/Oct/30 16:46", "ICI Caldaie", "ICI Caldaie", "Solar", "Micro 24F", "", "2003", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "25.3", "25.3", "", "", "81.2", "71.1", "", "50.0", "", "2", "", "", "104", "1", "2", "10", "120", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "", "", "0004", "", "", "", "", "", "", "", "", "84.3", "81.8", "", "", "", "", "82.3"]} +{"pcdb_id": 9871, "brand_name": "Warmflow", "model_name": "Wall Mounted", "model_qualifier": "50/70 External", "winter_efficiency_pct": 85.9, "summer_efficiency_pct": 74.2, "comparative_hot_water_efficiency_pct": 54.2, "output_kw_max": 20.52, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009871", "000063", "0", "2012/Mar/27 10:12", "Warmflow Engineering", "Warmflow", "Wall Mounted", "50/70 External", "", "2003", "current", "4", "2", "2", "1", "0", "", "", "1", "1", "2", "14.65", "20.52", "", "", "85.9", "74.2", "", "54.2", "", "2", "", "", "201", "1", "1", "115", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "84.8", "87.0", "", "", "", "", "86.6"]} +{"pcdb_id": 9872, "brand_name": "Warmflow", "model_name": "Wall Mounted", "model_qualifier": "50/70 Internal", "winter_efficiency_pct": 85.9, "summer_efficiency_pct": 74.2, "comparative_hot_water_efficiency_pct": 54.2, "output_kw_max": 20.52, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009872", "000063", "0", "2012/Mar/27 10:12", "Warmflow Engineering", "Warmflow", "Wall Mounted", "50/70 Internal", "", "2003", "current", "4", "2", "1", "1", "0", "", "", "1", "3", "2", "14.65", "20.52", "", "", "85.9", "74.2", "", "54.2", "", "2", "", "", "201", "1", "1", "115", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "84.8", "87.0", "", "", "", "", "86.6"]} +{"pcdb_id": 9873, "brand_name": "Warmflow", "model_name": "Combi", "model_qualifier": "70/90 Kabin Pak", "winter_efficiency_pct": 83.9, "summer_efficiency_pct": 75.8, "comparative_hot_water_efficiency_pct": 38.3, "output_kw_max": 26.38, "final_year_of_manufacture": 2007, "subsidiary_type": 0, "store_type": 1, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009873", "000063", "0", "2024/Jan/31 10:17", "Warmflow Engineering", "Warmflow", "Combi", "70/90 Kabin Pak", "", "2002", "2007", "4", "1", "2", "2", "0", "", "", "1", "1", "2", "20.52", "26.38", "", "", "83.9", "75.8", "", "38.3", "", "2", "", "", "203", "1", "1", "115", "0", "1", "1", "0", "70", "0", "25", "6", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "84.8", "86.8", "", "", "", "", "86.4"]} +{"pcdb_id": 9875, "brand_name": "Trianco", "model_name": "Tristar Optima", "model_qualifier": "Combi 28 CB", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 61.9, "output_kw_max": 28.0, "final_year_of_manufacture": 2007, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009875", "000062", "0", "2009/Mar/24 12:11", "Trianco Redfyre", "Trianco", "Tristar Optima", "Combi 28 CB", "", "2003", "2007", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28", "28", "", "", "87.9", "79.3", "", "61.9", "", "2", "", "", "104", "1", "2", "110", "12.4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "", "0005", "", "", "", "", "", "", "", "", "87.9", "96.5", "", "", "", "", "94.9"]} +{"pcdb_id": 9877, "brand_name": "Trianco", "model_name": "Tristar Optima", "model_qualifier": "Combi 28CB LPG", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 62.7, "output_kw_max": 28.0, "final_year_of_manufacture": 2007, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009877", "000062", "0", "2009/Mar/24 12:11", "Trianco Redfyre", "Trianco", "Tristar Optima", "Combi 28CB LPG", "", "2003", "2007", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "28", "28", "", "", "88.9", "80.3", "", "62.7", "", "2", "1", "", "104", "1", "2", "110", "12.4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "", "0005", "", "", "", "", "", "", "", "", "89.9", "98.6", "", "", "", "", "97.0"]} +{"pcdb_id": 9878, "brand_name": "Trianco", "model_name": "Tristar Optima", "model_qualifier": "System 28 SB", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 78.9, "comparative_hot_water_efficiency_pct": 57.6, "output_kw_max": 28.0, "final_year_of_manufacture": 2007, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009878", "000062", "0", "2012/Mar/27 10:12", "Trianco Redfyre", "Trianco", "Tristar Optima", "System 28 SB", "", "2003", "2007", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "28", "28", "", "", "87.9", "78.9", "", "57.6", "", "2", "", "", "102", "1", "2", "110", "12.4", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "96.5", "", "", "", "", "94.9"]} +{"pcdb_id": 9879, "brand_name": "Trianco", "model_name": "Tristar Optima", "model_qualifier": "System 28 SB LPG", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 28.0, "final_year_of_manufacture": 2007, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009879", "000062", "0", "2012/Mar/27 10:12", "Trianco Redfyre", "Trianco", "Tristar Optima", "System 28 SB LPG", "", "2003", "2007", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "28", "28", "", "", "88.9", "79.9", "", "58.3", "", "2", "1", "", "102", "1", "2", "110", "12.4", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.9", "98.6", "", "", "", "", "97.0"]} +{"pcdb_id": 9880, "brand_name": "Chaffoteaux et Maury", "model_name": "MX2 24 FF", "model_qualifier": "Minima", "winter_efficiency_pct": 79.0, "summer_efficiency_pct": 68.9, "comparative_hot_water_efficiency_pct": 48.5, "output_kw_max": 24.0, "final_year_of_manufacture": 2007, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009880", "000010", "0", "2008/Feb/04 08:38", "Chaffoteaux et Maury", "Chaffoteaux et Maury", "MX2 24 FF", "Minima", "GC No. 41-980-28", "2003", "2007", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "24.0", "24.0", "", "", "79.0", "68.9", "", "48.5", "", "2", "", "", "104", "1", "2", "150", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.1", "78.4", "", "", "", "", "79.1"]} +{"pcdb_id": 9881, "brand_name": "Chaffoteaux et Maury", "model_name": "MX2 24 FF LPG", "model_qualifier": "Minima", "winter_efficiency_pct": 80.8, "summer_efficiency_pct": 70.7, "comparative_hot_water_efficiency_pct": 49.7, "output_kw_max": 24.0, "final_year_of_manufacture": 2007, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009881", "000010", "0", "2008/Feb/04 08:38", "Chaffoteaux et Maury", "Chaffoteaux et Maury", "MX2 24 FF LPG", "Minima", "", "2003", "2007", "2", "2", "1", "2", "0", "", "", "1", "2", "2", "24.0", "24.0", "", "", "80.8", "70.7", "", "49.7", "", "2", "1", "", "104", "1", "2", "150", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "83.9", "80.1", "", "", "", "", "80.8"]} +{"pcdb_id": 9882, "brand_name": "Chaffoteaux et Maury", "model_name": "MX2 30 FF", "model_qualifier": "Minima", "winter_efficiency_pct": 80.3, "summer_efficiency_pct": 70.2, "comparative_hot_water_efficiency_pct": 49.4, "output_kw_max": 30.0, "final_year_of_manufacture": 2007, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009882", "000010", "0", "2008/Feb/04 08:38", "Chaffoteaux et Maury", "Chaffoteaux et Maury", "MX2 30 FF", "Minima", "GC No. 41-980-29", "2003", "2007", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "30.0", "30.0", "", "", "80.3", "70.2", "", "49.4", "", "2", "", "", "104", "1", "2", "150", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "83.6", "80.1", "", "", "", "", "80.8"]} +{"pcdb_id": 9883, "brand_name": "Chaffoteaux et Maury", "model_name": "MX2 30 FF LPG", "model_qualifier": "Minima", "winter_efficiency_pct": 82.1, "summer_efficiency_pct": 72.0, "comparative_hot_water_efficiency_pct": 50.6, "output_kw_max": 30.0, "final_year_of_manufacture": 2007, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009883", "000010", "0", "2008/Feb/04 08:38", "Chaffoteaux et Maury", "Chaffoteaux et Maury", "MX2 30 FF LPG", "Minima", "", "2003", "2007", "2", "2", "1", "2", "0", "", "", "1", "2", "2", "30.0", "30.0", "", "", "82.1", "72.0", "", "50.6", "", "2", "1", "", "104", "1", "2", "150", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "85.5", "81.9", "", "", "", "", "82.6"]} +{"pcdb_id": 9886, "brand_name": "Econoflame", "model_name": "Econoflame R30/65", "model_qualifier": "", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 65.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009886", "000236", "0", "2012/Mar/27 10:12", "Stokvis Energy Systems", "Econoflame", "Econoflame R30/65", "", "", "2003", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "65", "65", "", "", "88.2", "79.2", "", "57.8", "", "2", "", "", "102", "1", "2", "98", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "97.3", "", "", "", "", "95.5"]} +{"pcdb_id": 9887, "brand_name": "Econoflame", "model_name": "Econoflame R30/45", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 43.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009887", "000236", "0", "2012/Mar/27 10:12", "Stokvis Energy Systems", "Econoflame", "Econoflame R30/45", "", "", "2003", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "43.0", "43.0", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "97", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.2", "97.8", "", "", "", "", "95.9"]} +{"pcdb_id": 9889, "brand_name": "Econoflame", "model_name": "Econoflame R30/65", "model_qualifier": "LPG", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 65.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009889", "000236", "0", "2012/Mar/27 10:12", "Stokvis Energy Systems", "Econoflame", "Econoflame R30/65", "LPG", "", "2003", "current", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "65", "65", "", "", "89.2", "80.2", "", "58.6", "", "2", "1", "", "102", "1", "2", "98", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.8", "99.5", "", "", "", "", "97.6"]} +{"pcdb_id": 9890, "brand_name": "Econoflame", "model_name": "Econoflame R30/45", "model_qualifier": "LPG", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 80.4, "comparative_hot_water_efficiency_pct": 58.7, "output_kw_max": 43.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009890", "000236", "0", "2012/Mar/27 10:12", "Stokvis Energy Systems", "Econoflame", "Econoflame R30/45", "LPG", "", "2003", "current", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "43", "43", "", "", "89.4", "80.4", "", "58.7", "", "2", "1", "", "102", "1", "2", "97", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.2", "99.9", "", "", "", "", "98.1"]} +{"pcdb_id": 9891, "brand_name": "ELCO Klockner Heiztechnik", "model_name": "Ultron 22", "model_qualifier": "", "winter_efficiency_pct": 85.2, "summer_efficiency_pct": 77.6, "comparative_hot_water_efficiency_pct": 56.7, "output_kw_max": 21.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009891", "000237", "0", "2012/Mar/27 10:12", "ELCO Klöckner Heiztechnik", "ELCO Klockner Heiztechnik", "Ultron 22", "", "", "1994", "current", "1", "1", "1", "1", "0", "", "", "2", "3", "2", "4", "21", "", "", "85.2", "77.6", "", "56.7", "", "2", "", "", "101", "1", "1", "45", "56", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "89.2", "92.8", "", "", "", "", "92.1"]} +{"pcdb_id": 9892, "brand_name": "Radiant", "model_name": "RBA CS 30/100", "model_qualifier": "", "winter_efficiency_pct": 81.9, "summer_efficiency_pct": 72.8, "comparative_hot_water_efficiency_pct": 32.9, "output_kw_max": 31.9, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009892", "000088", "0", "2024/Jan/31 10:17", "Radiant Bruciatori SpA", "Radiant", "RBA CS 30/100", "", "", "2003", "current", "1", "1", "1", "2", "0", "", "", "1", "2", "2", "31.90", "31.90", "", "", "81.9", "72.8", "", "32.9", "", "2", "", "", "106", "1", "2", "170", "", "2", "2", "0", "104", "0", "15", "2", "60", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "83.3", "81.5", "", "", "", "", "81.9"]} +{"pcdb_id": 9893, "brand_name": "Radiant", "model_name": "RBA CS 30", "model_qualifier": "", "winter_efficiency_pct": 81.6, "summer_efficiency_pct": 72.5, "comparative_hot_water_efficiency_pct": 38.6, "output_kw_max": 31.9, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009893", "000088", "0", "2024/Jan/31 10:17", "Radiant Bruciatori SpA", "Radiant", "RBA CS 30", "", "", "2003", "current", "1", "1", "1", "2", "0", "", "", "1", "2", "2", "31.90", "31.90", "", "", "81.6", "72.5", "", "38.6", "", "2", "", "", "106", "1", "2", "170", "", "2", "2", "0", "48.6", "0", "15", "2", "60", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "83.3", "81.5", "", "", "", "", "81.9"]} +{"pcdb_id": 9894, "brand_name": "Radiant", "model_name": "RMAS 20", "model_qualifier": "", "winter_efficiency_pct": 80.0, "summer_efficiency_pct": 69.9, "comparative_hot_water_efficiency_pct": 49.2, "output_kw_max": 23.76, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009894", "000088", "0", "2006/Jan/17 12:31", "Radiant Bruciatori SpA", "Radiant", "RMAS 20", "", "", "2003", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "23.76", "23.76", "", "", "80.0", "69.9", "", "49.2", "", "2", "", "", "104", "1", "2", "170", "", "0", "", "", "8.8", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "83.4", "79.6", "", "", "", "", "80.3"]} +{"pcdb_id": 9895, "brand_name": "Ideal", "model_name": "icos", "model_qualifier": "HE15", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 14.6, "final_year_of_manufacture": 2011, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009895", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "icos", "HE15", "47-397-83", "2003", "2011", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "14.6", "14.6", "", "", "89.0", "80.0", "", "58.4", "", "2", "", "", "102", "1", "2", "38", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.5", "99.0", "", "", "", "", "97.0"]} +{"pcdb_id": 9896, "brand_name": "Ideal", "model_name": "icos", "model_qualifier": "HE18", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 18.2, "final_year_of_manufacture": 2011, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009896", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "icos", "HE18", "47-397-84", "2003", "2011", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18.2", "18.2", "", "", "88.7", "79.7", "", "58.2", "", "2", "", "", "102", "1", "2", "38", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.2", "98.5", "", "", "", "", "96.5"]} +{"pcdb_id": 9897, "brand_name": "Ideal", "model_name": "icos", "model_qualifier": "HE24", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 23.4, "final_year_of_manufacture": 2011, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009897", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "icos", "HE24", "47-397-85", "2003", "2011", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "23.4", "23.4", "", "", "88.1", "79.1", "", "57.8", "", "2", "", "", "102", "1", "2", "38", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "97.1", "", "", "", "", "95.4"]} +{"pcdb_id": 9898, "brand_name": "Ideal", "model_name": "icos System", "model_qualifier": "HE 24", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 23.4, "final_year_of_manufacture": 2011, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009898", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "icos System", "HE 24", "41-397-82", "2003", "2011", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "23.4", "23.4", "", "", "88.1", "79.1", "", "57.8", "", "2", "", "", "102", "1", "2", "38", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "97.1", "", "", "", "", "95.4"]} +{"pcdb_id": 9899, "brand_name": "Ideal", "model_name": "isar", "model_qualifier": "HE24", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 55.9, "output_kw_max": 23.4, "final_year_of_manufacture": 2011, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009899", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "isar", "HE24", "47-348-31", "2003", "2011", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "23.4", "23.4", "", "", "88.1", "79.5", "", "55.9", "", "2", "", "", "104", "1", "2", "148", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "97.1", "", "", "", "", "95.4"]} +{"pcdb_id": 9900, "brand_name": "Ideal", "model_name": "isar", "model_qualifier": "HE30", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 55.9, "output_kw_max": 23.4, "final_year_of_manufacture": 2011, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009900", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "isar", "HE30", "41-348-30", "2003", "2011", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "23.4", "23.4", "", "", "88.1", "79.5", "", "55.9", "", "2", "", "", "104", "1", "2", "148", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "97.1", "", "", "", "", "95.4"]} +{"pcdb_id": 9901, "brand_name": "Ideal", "model_name": "isar", "model_qualifier": "HE35", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 55.9, "output_kw_max": 23.4, "final_year_of_manufacture": 2011, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009901", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "isar", "HE35", "47-348-29", "2003", "2011", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "23.4", "23.4", "", "", "88.1", "79.5", "", "55.9", "", "2", "", "", "104", "1", "2", "148", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "97.1", "", "", "", "", "95.4"]} +{"pcdb_id": 9902, "brand_name": "Ideal", "model_name": "istor", "model_qualifier": "HE260", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 81.1, "comparative_hot_water_efficiency_pct": 46.0, "output_kw_max": 23.4, "final_year_of_manufacture": 2011, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009902", "000008", "0", "2024/Jan/31 10:17", "Ideal Boilers", "Ideal", "istor", "HE260", "41-394-13", "2003", "2011", "1", "1", "1", "2", "0", "", "", "2", "2", "2", "23.4", "23.4", "", "", "88.1", "81.1", "", "46.0", "", "2", "", "", "106", "1", "2", "148", "7", "2", "2", "0", "80", "0", "25", "2", "70", "1880", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "97.1", "", "", "", "", "95.4"]} +{"pcdb_id": 9903, "brand_name": "Ideal", "model_name": "istor", "model_qualifier": "HE325", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 81.2, "comparative_hot_water_efficiency_pct": 42.4, "output_kw_max": 23.4, "final_year_of_manufacture": 2011, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009903", "000008", "0", "2024/Jan/31 10:17", "Ideal Boilers", "Ideal", "istor", "HE325", "41-394-14", "2003", "2011", "1", "1", "1", "2", "0", "", "", "2", "2", "2", "23.4", "23.4", "", "", "88.1", "81.2", "", "42.4", "", "2", "", "", "106", "1", "2", "148", "7", "2", "2", "0", "120", "0", "25", "2", "70", "2520", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "97.1", "", "", "", "", "95.4"]} +{"pcdb_id": 9904, "brand_name": "Ideal", "model_name": "Classic", "model_qualifier": "SE9 FF", "winter_efficiency_pct": 80.4, "summer_efficiency_pct": 70.3, "comparative_hot_water_efficiency_pct": 51.4, "output_kw_max": 8.8, "final_year_of_manufacture": 2011, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009904", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "Classic", "SE9 FF", "GC No. 41 395 30", "2003", "2011", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "8.8", "8.8", "", "", "80.4", "70.3", "", "51.4", "", "2", "", "", "101", "1", "1", "100", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.9", "82.2", "", "", "", "", "82.1"]} +{"pcdb_id": 9905, "brand_name": "Ideal", "model_name": "Classic", "model_qualifier": "SE12 FF", "winter_efficiency_pct": 79.5, "summer_efficiency_pct": 69.4, "comparative_hot_water_efficiency_pct": 50.7, "output_kw_max": 11.7, "final_year_of_manufacture": 2011, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009905", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "Classic", "SE12 FF", "GC No. 41 395 31", "2003", "2011", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "11.7", "11.7", "", "", "79.5", "69.4", "", "50.7", "", "2", "", "", "101", "1", "1", "100", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.0", "81.3", "", "", "", "", "81.2"]} +{"pcdb_id": 9906, "brand_name": "Ideal", "model_name": "Classic", "model_qualifier": "SE15 FF", "winter_efficiency_pct": 80.7, "summer_efficiency_pct": 70.6, "comparative_hot_water_efficiency_pct": 51.5, "output_kw_max": 14.7, "final_year_of_manufacture": 2011, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009906", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "Classic", "SE15 FF", "GC No. 41 395 32", "2003", "2011", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "14.7", "14.7", "", "", "80.7", "70.6", "", "51.5", "", "2", "", "", "101", "1", "1", "100", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.3", "82.3", "", "", "", "", "82.3"]} +{"pcdb_id": 9907, "brand_name": "Ideal", "model_name": "Classic", "model_qualifier": "SE18 FF", "winter_efficiency_pct": 79.2, "summer_efficiency_pct": 69.1, "comparative_hot_water_efficiency_pct": 50.5, "output_kw_max": 17.6, "final_year_of_manufacture": 2011, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009907", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "Classic", "SE18 FF", "GC No. 41 395 33", "2003", "2011", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "17.6", "17.6", "", "", "79.2", "69.1", "", "50.5", "", "2", "", "", "101", "1", "1", "100", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "80.8", "80.7", "", "", "", "", "80.7"]} +{"pcdb_id": 9908, "brand_name": "Ideal", "model_name": "Classic", "model_qualifier": "SE21 FF", "winter_efficiency_pct": 79.4, "summer_efficiency_pct": 69.3, "comparative_hot_water_efficiency_pct": 50.6, "output_kw_max": 20.5, "final_year_of_manufacture": 2011, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009908", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "Classic", "SE21 FF", "GC No. 41 395 34", "2003", "2011", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "20.5", "20.5", "", "", "79.4", "69.3", "", "50.6", "", "2", "", "", "101", "1", "1", "100", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.2", "80.8", "", "", "", "", "80.9"]} +{"pcdb_id": 9909, "brand_name": "Ideal", "model_name": "Classic", "model_qualifier": "SE24 FF", "winter_efficiency_pct": 79.0, "summer_efficiency_pct": 68.9, "comparative_hot_water_efficiency_pct": 50.3, "output_kw_max": 23.4, "final_year_of_manufacture": 2011, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009909", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "Classic", "SE24 FF", "GC No. 41 395 35", "2003", "2011", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "23.4", "23.4", "", "", "79.0", "68.9", "", "50.3", "", "2", "", "", "101", "1", "1", "100", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "80.6", "80.5", "", "", "", "", "80.6"]} +{"pcdb_id": 9910, "brand_name": "Ideal", "model_name": "Classic", "model_qualifier": "SE30 FF", "winter_efficiency_pct": 78.9, "summer_efficiency_pct": 68.8, "comparative_hot_water_efficiency_pct": 50.3, "output_kw_max": 29.3, "final_year_of_manufacture": 2011, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009910", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "Classic", "SE30 FF", "GC No. 41 395 36", "2003", "2011", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "29.3", "29.3", "", "", "78.9", "68.8", "", "50.3", "", "2", "", "", "101", "1", "1", "100", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "80.5", "80.5", "", "", "", "", "80.5"]} +{"pcdb_id": 9914, "brand_name": "Ideal", "model_name": "Classic Slimline", "model_qualifier": "SE9 FF", "winter_efficiency_pct": 81.6, "summer_efficiency_pct": 71.5, "comparative_hot_water_efficiency_pct": 52.2, "output_kw_max": 8.8, "final_year_of_manufacture": 2011, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009914", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "Classic Slimline", "SE9 FF", "GC No. 41 395 40", "2003", "2011", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "8.8", "8.8", "", "", "81.6", "71.5", "", "52.2", "", "2", "", "", "101", "1", "1", "100", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "83.1", "83.4", "", "", "", "", "83.4"]} +{"pcdb_id": 9915, "brand_name": "Ideal", "model_name": "Classic Slimline", "model_qualifier": "SE12 FF", "winter_efficiency_pct": 80.1, "summer_efficiency_pct": 70.0, "comparative_hot_water_efficiency_pct": 51.1, "output_kw_max": 11.7, "final_year_of_manufacture": 2011, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009915", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "Classic Slimline", "SE12 FF", "GC No. 41 395 41", "2003", "2011", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "11.7", "11.7", "", "", "80.1", "70.0", "", "51.1", "", "2", "", "", "101", "1", "1", "100", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.8", "81.5", "", "", "", "", "81.6"]} +{"pcdb_id": 9916, "brand_name": "Ideal", "model_name": "Classic Slimline", "model_qualifier": "SE15 FF", "winter_efficiency_pct": 81.4, "summer_efficiency_pct": 71.3, "comparative_hot_water_efficiency_pct": 52.1, "output_kw_max": 14.7, "final_year_of_manufacture": 2011, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009916", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "Classic Slimline", "SE15 FF", "GC No. 41 395 42", "2003", "2011", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "14.7", "14.7", "", "", "81.4", "71.3", "", "52.1", "", "2", "", "", "101", "1", "1", "100", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "83.0", "83.1", "", "", "", "", "83.1"]} +{"pcdb_id": 9917, "brand_name": "Ideal", "model_name": "Classic Slimline", "model_qualifier": "SE18 FF", "winter_efficiency_pct": 80.8, "summer_efficiency_pct": 70.7, "comparative_hot_water_efficiency_pct": 51.6, "output_kw_max": 17.6, "final_year_of_manufacture": 2011, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009917", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "Classic Slimline", "SE18 FF", "GC No. 41 395 43", "2003", "2011", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "17.6", "17.6", "", "", "80.8", "70.7", "", "51.6", "", "2", "", "", "101", "1", "1", "100", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.4", "82.4", "", "", "", "", "82.4"]} +{"pcdb_id": 9918, "brand_name": "Ideal", "model_name": "Classic", "model_qualifier": "SE9 RS", "winter_efficiency_pct": 79.2, "summer_efficiency_pct": 69.1, "comparative_hot_water_efficiency_pct": 50.5, "output_kw_max": 8.8, "final_year_of_manufacture": 2005, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009918", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "Classic", "SE9 RS", "GC No. 41 395 44", "2003", "2005", "1", "2", "1", "1", "0", "", "", "1", "2", "1", "8.8", "8.8", "", "", "79.2", "69.1", "", "50.5", "", "2", "", "", "101", "1", "1", "10", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.2", "80.5", "", "", "", "", "80.6"]} +{"pcdb_id": 9919, "brand_name": "Ideal", "model_name": "Classic", "model_qualifier": "SE12 RS", "winter_efficiency_pct": 79.8, "summer_efficiency_pct": 69.7, "comparative_hot_water_efficiency_pct": 50.9, "output_kw_max": 11.7, "final_year_of_manufacture": 2005, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009919", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "Classic", "SE12 RS", "GC No. 41 395 45", "2003", "2005", "1", "2", "1", "1", "0", "", "", "1", "2", "1", "11.7", "11.7", "", "", "79.8", "69.7", "", "50.9", "", "2", "", "", "101", "1", "1", "10", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.2", "81.5", "", "", "", "", "81.5"]} +{"pcdb_id": 9920, "brand_name": "Ideal", "model_name": "Classic", "model_qualifier": "SE15 RS", "winter_efficiency_pct": 81.2, "summer_efficiency_pct": 71.1, "comparative_hot_water_efficiency_pct": 51.9, "output_kw_max": 14.7, "final_year_of_manufacture": 2005, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009920", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "Classic", "SE15 RS", "GC No. 41 395 46", "2003", "2005", "1", "2", "1", "1", "0", "", "", "1", "2", "1", "14.7", "14.7", "", "", "81.2", "71.1", "", "51.9", "", "2", "", "", "101", "1", "1", "10", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.9", "82.6", "", "", "", "", "82.7"]} +{"pcdb_id": 9921, "brand_name": "Ideal", "model_name": "Classic", "model_qualifier": "SE18 RS", "winter_efficiency_pct": 79.9, "summer_efficiency_pct": 69.8, "comparative_hot_water_efficiency_pct": 51.0, "output_kw_max": 17.6, "final_year_of_manufacture": 2005, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009921", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "Classic", "SE18 RS", "GC No. 41 395 99", "2003", "2005", "1", "2", "1", "1", "0", "", "", "1", "2", "1", "17.6", "17.6", "", "", "79.9", "69.8", "", "51.0", "", "2", "", "", "101", "1", "1", "10", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.9", "81.1", "", "", "", "", "81.2"]} +{"pcdb_id": 9922, "brand_name": "British / Scottish Gas", "model_name": "RD109", "model_qualifier": "", "winter_efficiency_pct": 80.4, "summer_efficiency_pct": 70.3, "comparative_hot_water_efficiency_pct": 51.4, "output_kw_max": 8.8, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009922", "000008", "0", "2012/Mar/27 10:12", "Ideal Boilers", "British / Scottish Gas", "RD109", "", "GC No. 41 397 56", "2003", "current", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "8.8", "8.8", "", "", "80.4", "70.3", "", "51.4", "", "2", "", "", "101", "1", "1", "150", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.9", "82.2", "", "", "", "", "82.1"]} +{"pcdb_id": 9923, "brand_name": "British / Scottish Gas", "model_name": "RD112", "model_qualifier": "", "winter_efficiency_pct": 79.5, "summer_efficiency_pct": 69.4, "comparative_hot_water_efficiency_pct": 50.7, "output_kw_max": 11.7, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009923", "000008", "0", "2012/Mar/27 10:12", "Ideal Boilers", "British / Scottish Gas", "RD112", "", "GC No. 41 397 57", "2003", "current", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "11.7", "11.7", "", "", "79.5", "69.4", "", "50.7", "", "2", "", "", "101", "1", "1", "150", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.0", "81.3", "", "", "", "", "81.2"]} +{"pcdb_id": 9924, "brand_name": "British / Scottish Gas", "model_name": "RD115", "model_qualifier": "", "winter_efficiency_pct": 80.7, "summer_efficiency_pct": 70.6, "comparative_hot_water_efficiency_pct": 51.5, "output_kw_max": 14.7, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009924", "000008", "0", "2012/Mar/27 10:12", "Ideal Boilers", "British / Scottish Gas", "RD115", "", "GC No. 41 397 58", "2003", "current", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "14.7", "14.7", "", "", "80.7", "70.6", "", "51.5", "", "2", "", "", "101", "1", "1", "150", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.3", "82.3", "", "", "", "", "82.3"]} +{"pcdb_id": 9925, "brand_name": "British / Scottish Gas", "model_name": "RD118", "model_qualifier": "", "winter_efficiency_pct": 79.2, "summer_efficiency_pct": 69.1, "comparative_hot_water_efficiency_pct": 50.5, "output_kw_max": 17.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009925", "000008", "0", "2012/Mar/27 10:12", "Ideal Boilers", "British / Scottish Gas", "RD118", "", "GC No. 41 397 59", "2003", "current", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "17.6", "17.6", "", "", "79.2", "69.1", "", "50.5", "", "2", "", "", "101", "1", "1", "150", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "80.8", "80.7", "", "", "", "", "80.7"]} +{"pcdb_id": 9926, "brand_name": "British / Scottish Gas", "model_name": "RD121", "model_qualifier": "", "winter_efficiency_pct": 79.4, "summer_efficiency_pct": 69.3, "comparative_hot_water_efficiency_pct": 50.6, "output_kw_max": 20.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009926", "000008", "0", "2012/Mar/27 10:12", "Ideal Boilers", "British / Scottish Gas", "RD121", "", "GC No. 41 397 60", "2003", "current", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "20.5", "20.5", "", "", "79.4", "69.3", "", "50.6", "", "2", "", "", "101", "1", "1", "150", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.2", "80.8", "", "", "", "", "80.9"]} +{"pcdb_id": 9927, "brand_name": "British / Scottish Gas", "model_name": "RD124", "model_qualifier": "", "winter_efficiency_pct": 79.0, "summer_efficiency_pct": 68.9, "comparative_hot_water_efficiency_pct": 50.3, "output_kw_max": 23.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009927", "000008", "0", "2012/Mar/27 10:12", "Ideal Boilers", "British / Scottish Gas", "RD124", "", "GC No. 41 397 61", "2003", "current", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "23.4", "23.4", "", "", "79.0", "68.9", "", "50.3", "", "2", "", "", "101", "1", "1", "150", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "80.6", "80.5", "", "", "", "", "80.6"]} +{"pcdb_id": 9928, "brand_name": "British / Scottish Gas", "model_name": "RD130", "model_qualifier": "", "winter_efficiency_pct": 78.9, "summer_efficiency_pct": 68.8, "comparative_hot_water_efficiency_pct": 50.3, "output_kw_max": 29.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009928", "000008", "0", "2012/Mar/27 10:12", "Ideal Boilers", "British / Scottish Gas", "RD130", "", "GC No. 41 397 62", "2003", "current", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "29.3", "29.3", "", "", "78.9", "68.8", "", "50.3", "", "2", "", "", "101", "1", "1", "150", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "80.5", "80.5", "", "", "", "", "80.5"]} +{"pcdb_id": 9929, "brand_name": "Ideal", "model_name": "Classic", "model_qualifier": "SE9 FF Silver", "winter_efficiency_pct": 80.4, "summer_efficiency_pct": 70.3, "comparative_hot_water_efficiency_pct": 51.4, "output_kw_max": 8.8, "final_year_of_manufacture": 2005, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009929", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "Classic", "SE9 FF Silver", "GC No. 41 397 63", "2003", "2005", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "8.8", "8.8", "", "", "80.4", "70.3", "", "51.4", "", "2", "", "", "101", "1", "1", "100", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.9", "82.2", "", "", "", "", "82.1"]} +{"pcdb_id": 9930, "brand_name": "Ideal", "model_name": "Classic", "model_qualifier": "SE12 FF Silver", "winter_efficiency_pct": 79.5, "summer_efficiency_pct": 69.4, "comparative_hot_water_efficiency_pct": 50.7, "output_kw_max": 11.7, "final_year_of_manufacture": 2005, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009930", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "Classic", "SE12 FF Silver", "GC No. 41 397 64", "2003", "2005", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "11.7", "11.7", "", "", "79.5", "69.4", "", "50.7", "", "2", "", "", "101", "1", "1", "100", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.0", "81.3", "", "", "", "", "81.2"]} +{"pcdb_id": 9931, "brand_name": "Ideal", "model_name": "Classic", "model_qualifier": "SE15 FF Silver", "winter_efficiency_pct": 80.7, "summer_efficiency_pct": 70.6, "comparative_hot_water_efficiency_pct": 51.5, "output_kw_max": 14.7, "final_year_of_manufacture": 2005, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009931", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "Classic", "SE15 FF Silver", "GC No. 41 397 65", "2003", "2005", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "14.7", "14.7", "", "", "80.7", "70.6", "", "51.5", "", "2", "", "", "101", "1", "1", "100", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.3", "82.3", "", "", "", "", "82.3"]} +{"pcdb_id": 9932, "brand_name": "Ideal", "model_name": "Classic", "model_qualifier": "SE18 FF Silver", "winter_efficiency_pct": 79.2, "summer_efficiency_pct": 69.1, "comparative_hot_water_efficiency_pct": 50.5, "output_kw_max": 17.6, "final_year_of_manufacture": 2005, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009932", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "Classic", "SE18 FF Silver", "GC No. 41 397 68", "2003", "2005", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "17.6", "17.6", "", "", "79.2", "69.1", "", "50.5", "", "2", "", "", "101", "1", "1", "100", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "80.8", "80.7", "", "", "", "", "80.7"]} +{"pcdb_id": 9933, "brand_name": "Ideal", "model_name": "Classic", "model_qualifier": "SE21 FF Silver", "winter_efficiency_pct": 79.4, "summer_efficiency_pct": 69.3, "comparative_hot_water_efficiency_pct": 50.6, "output_kw_max": 20.5, "final_year_of_manufacture": 2005, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009933", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "Classic", "SE21 FF Silver", "GC No. 41 397 69", "2003", "2005", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "20.5", "20.5", "", "", "79.4", "69.3", "", "50.6", "", "2", "", "", "101", "1", "1", "100", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.2", "80.8", "", "", "", "", "80.9"]} +{"pcdb_id": 9934, "brand_name": "Ideal", "model_name": "Classic", "model_qualifier": "SE24 FF Silver", "winter_efficiency_pct": 79.0, "summer_efficiency_pct": 68.9, "comparative_hot_water_efficiency_pct": 50.3, "output_kw_max": 23.4, "final_year_of_manufacture": 2005, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009934", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "Classic", "SE24 FF Silver", "GC No. 41 397 70", "2003", "2005", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "23.4", "23.4", "", "", "79.0", "68.9", "", "50.3", "", "2", "", "", "101", "1", "1", "100", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "80.6", "80.5", "", "", "", "", "80.6"]} +{"pcdb_id": 9935, "brand_name": "Ideal", "model_name": "Classic", "model_qualifier": "SE30 FF Silver", "winter_efficiency_pct": 78.9, "summer_efficiency_pct": 68.8, "comparative_hot_water_efficiency_pct": 50.3, "output_kw_max": 29.3, "final_year_of_manufacture": 2005, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009935", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "Classic", "SE30 FF Silver", "GC No. 41 397 71", "2003", "2005", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "29.3", "29.3", "", "", "78.9", "68.8", "", "50.3", "", "2", "", "", "101", "1", "1", "100", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "80.5", "80.5", "", "", "", "", "80.5"]} +{"pcdb_id": 9939, "brand_name": "British / Scottish Gas", "model_name": "RD109 Silver", "model_qualifier": "", "winter_efficiency_pct": 80.4, "summer_efficiency_pct": 70.3, "comparative_hot_water_efficiency_pct": 51.4, "output_kw_max": 8.8, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009939", "000008", "0", "2012/Mar/27 10:12", "Ideal Boilers", "British / Scottish Gas", "RD109 Silver", "", "GC No. 41 397 75", "2003", "current", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "8.8", "8.8", "", "", "80.4", "70.3", "", "51.4", "", "2", "", "", "101", "1", "1", "150", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.9", "82.2", "", "", "", "", "82.1"]} +{"pcdb_id": 9940, "brand_name": "British / Scottish Gas", "model_name": "RD112 Silver", "model_qualifier": "", "winter_efficiency_pct": 79.5, "summer_efficiency_pct": 69.4, "comparative_hot_water_efficiency_pct": 50.7, "output_kw_max": 11.7, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009940", "000008", "0", "2012/Mar/27 10:12", "Ideal Boilers", "British / Scottish Gas", "RD112 Silver", "", "GC No. 41 397 76", "2003", "current", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "11.7", "11.7", "", "", "79.5", "69.4", "", "50.7", "", "2", "", "", "101", "1", "1", "150", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.0", "81.3", "", "", "", "", "81.2"]} +{"pcdb_id": 9941, "brand_name": "British / Scottish Gas", "model_name": "RD115 Silver", "model_qualifier": "", "winter_efficiency_pct": 80.7, "summer_efficiency_pct": 70.6, "comparative_hot_water_efficiency_pct": 51.5, "output_kw_max": 14.7, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009941", "000008", "0", "2012/Mar/27 10:12", "Ideal Boilers", "British / Scottish Gas", "RD115 Silver", "", "GC No. 41 397 77", "2003", "current", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "14.7", "14.7", "", "", "80.7", "70.6", "", "51.5", "", "2", "", "", "101", "1", "1", "150", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.3", "82.3", "", "", "", "", "82.3"]} +{"pcdb_id": 9942, "brand_name": "British / Scottish Gas", "model_name": "RD118 Silver", "model_qualifier": "", "winter_efficiency_pct": 79.2, "summer_efficiency_pct": 69.1, "comparative_hot_water_efficiency_pct": 50.5, "output_kw_max": 17.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009942", "000008", "0", "2012/Mar/27 10:12", "Ideal Boilers", "British / Scottish Gas", "RD118 Silver", "", "GC No. 41 397 78", "2003", "current", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "17.6", "17.6", "", "", "79.2", "69.1", "", "50.5", "", "2", "", "", "101", "1", "1", "150", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "80.8", "80.7", "", "", "", "", "80.7"]} +{"pcdb_id": 9943, "brand_name": "British / Scottish Gas", "model_name": "RD121 Silver", "model_qualifier": "", "winter_efficiency_pct": 79.4, "summer_efficiency_pct": 69.3, "comparative_hot_water_efficiency_pct": 50.6, "output_kw_max": 20.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009943", "000008", "0", "2012/Mar/27 10:12", "Ideal Boilers", "British / Scottish Gas", "RD121 Silver", "", "GC No. 41 397 79", "2003", "current", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "20.5", "20.5", "", "", "79.4", "69.3", "", "50.6", "", "2", "", "", "101", "1", "1", "150", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.2", "80.8", "", "", "", "", "80.9"]} +{"pcdb_id": 9944, "brand_name": "British / Scottish Gas", "model_name": "RD124 Silver", "model_qualifier": "", "winter_efficiency_pct": 79.0, "summer_efficiency_pct": 68.9, "comparative_hot_water_efficiency_pct": 50.3, "output_kw_max": 23.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009944", "000008", "0", "2012/Mar/27 10:12", "Ideal Boilers", "British / Scottish Gas", "RD124 Silver", "", "GC No. 41 397 80", "2003", "current", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "23.4", "23.4", "", "", "79.0", "68.9", "", "50.3", "", "2", "", "", "101", "1", "1", "150", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "80.6", "80.5", "", "", "", "", "80.6"]} +{"pcdb_id": 9945, "brand_name": "British / Scottish Gas", "model_name": "RD130 Silver", "model_qualifier": "", "winter_efficiency_pct": 78.9, "summer_efficiency_pct": 68.8, "comparative_hot_water_efficiency_pct": 50.3, "output_kw_max": 29.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009945", "000008", "0", "2012/Mar/27 10:12", "Ideal Boilers", "British / Scottish Gas", "RD130 Silver", "", "GC No. 41 397 81", "2003", "current", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "29.3", "29.3", "", "", "78.9", "68.8", "", "50.3", "", "2", "", "", "101", "1", "1", "150", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "80.5", "80.5", "", "", "", "", "80.5"]} +{"pcdb_id": 9946, "brand_name": "Optia", "model_name": "FF30", "model_qualifier": "", "winter_efficiency_pct": 80.4, "summer_efficiency_pct": 70.3, "comparative_hot_water_efficiency_pct": 51.4, "output_kw_max": 8.8, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009946", "000008", "0", "2012/Mar/27 10:12", "Ideal Boilers", "Optia", "FF30", "", "GC No. 41 391 54", "2003", "current", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "8.8", "8.8", "", "", "80.4", "70.3", "", "51.4", "", "2", "", "", "101", "1", "1", "100", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.9", "82.2", "", "", "", "", "82.1"]} +{"pcdb_id": 9947, "brand_name": "Optia", "model_name": "FF40", "model_qualifier": "", "winter_efficiency_pct": 79.5, "summer_efficiency_pct": 69.4, "comparative_hot_water_efficiency_pct": 50.7, "output_kw_max": 11.7, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009947", "000008", "0", "2012/Mar/27 10:12", "Ideal Boilers", "Optia", "FF40", "", "GC No. 41 391 95", "2003", "current", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "11.7", "11.7", "", "", "79.5", "69.4", "", "50.7", "", "2", "", "", "101", "1", "1", "100", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.0", "81.3", "", "", "", "", "81.2"]} +{"pcdb_id": 9948, "brand_name": "Optia", "model_name": "FF50", "model_qualifier": "", "winter_efficiency_pct": 80.7, "summer_efficiency_pct": 70.6, "comparative_hot_water_efficiency_pct": 51.5, "output_kw_max": 14.7, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009948", "000008", "0", "2012/Mar/27 10:12", "Ideal Boilers", "Optia", "FF50", "", "GC No. 41 391 96", "2003", "current", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "14.7", "14.7", "", "", "80.7", "70.6", "", "51.5", "", "2", "", "", "101", "1", "1", "100", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.3", "82.3", "", "", "", "", "82.3"]} +{"pcdb_id": 9949, "brand_name": "Optia", "model_name": "FF60", "model_qualifier": "", "winter_efficiency_pct": 79.2, "summer_efficiency_pct": 69.1, "comparative_hot_water_efficiency_pct": 50.5, "output_kw_max": 17.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009949", "000008", "0", "2012/Mar/27 10:12", "Ideal Boilers", "Optia", "FF60", "", "GC No. 41 391 97", "2003", "current", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "17.6", "17.6", "", "", "79.2", "69.1", "", "50.5", "", "2", "", "", "101", "1", "1", "100", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "80.8", "80.7", "", "", "", "", "80.7"]} +{"pcdb_id": 9950, "brand_name": "Optia", "model_name": "FF70", "model_qualifier": "", "winter_efficiency_pct": 79.4, "summer_efficiency_pct": 69.3, "comparative_hot_water_efficiency_pct": 50.6, "output_kw_max": 20.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009950", "000008", "0", "2012/Mar/27 10:12", "Ideal Boilers", "Optia", "FF70", "", "GC No. 41 391 98", "2003", "current", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "20.5", "20.5", "", "", "79.4", "69.3", "", "50.6", "", "2", "", "", "101", "1", "1", "100", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.2", "80.8", "", "", "", "", "80.9"]} +{"pcdb_id": 9951, "brand_name": "Optia", "model_name": "FF80", "model_qualifier": "", "winter_efficiency_pct": 79.0, "summer_efficiency_pct": 68.9, "comparative_hot_water_efficiency_pct": 50.3, "output_kw_max": 23.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009951", "000008", "0", "2012/Mar/27 10:12", "Ideal Boilers", "Optia", "FF80", "", "GC No. 41 391 99", "2003", "current", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "23.4", "23.4", "", "", "79.0", "68.9", "", "50.3", "", "2", "", "", "101", "1", "1", "100", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "80.6", "80.5", "", "", "", "", "80.6"]} +{"pcdb_id": 9952, "brand_name": "Optia", "model_name": "FF100", "model_qualifier": "", "winter_efficiency_pct": 78.9, "summer_efficiency_pct": 68.8, "comparative_hot_water_efficiency_pct": 50.3, "output_kw_max": 29.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009952", "000008", "0", "2012/Mar/27 10:12", "Ideal Boilers", "Optia", "FF100", "", "GC No. 41 391 01", "2003", "current", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "29.3", "29.3", "", "", "78.9", "68.8", "", "50.3", "", "2", "", "", "101", "1", "1", "100", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "80.5", "80.5", "", "", "", "", "80.5"]} +{"pcdb_id": 9953, "brand_name": "Saunier Duval", "model_name": "EnviroPlus F28E", "model_qualifier": "", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 56.4, "output_kw_max": 29.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009953", "000206", "0", "2009/Mar/31 14:32", "Hepworth Heating", "Saunier Duval", "EnviroPlus F28E", "", "GC 47-920-39", "2003", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "29.0", "29.0", "", "", "88.9", "80.3", "", "56.4", "", "2", "", "", "104", "1", "2", "180", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.4", "98.8", "", "", "", "", "96.9"]} +{"pcdb_id": 9954, "brand_name": "Saunier Duval", "model_name": "EnviroPlus F28E SB", "model_qualifier": "", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 29.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009954", "000206", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Saunier Duval", "EnviroPlus F28E SB", "", "GC 41-920-37", "2003", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "29.0", "29.0", "", "", "88.9", "79.9", "", "58.3", "", "2", "", "", "102", "1", "2", "180", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.4", "98.8", "", "", "", "", "96.9"]} +{"pcdb_id": 9955, "brand_name": "Alpha", "model_name": "CD32C", "model_qualifier": "", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 56.0, "output_kw_max": 32.0, "final_year_of_manufacture": 2007, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009955", "000001", "0", "2011/Sep/06 13:10", "Alpha Therm", "Alpha", "CD32C", "", "", "2003", "2007", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "32", "32", "", "", "88.2", "79.6", "", "56.0", "", "2", "", "", "104", "1", "2", "140", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.1", "96.8", "", "", "", "", "95.3"]} +{"pcdb_id": 9957, "brand_name": "MHS Boilers", "model_name": "Strata Streamline", "model_qualifier": "75", "winter_efficiency_pct": 87.7, "summer_efficiency_pct": 78.7, "comparative_hot_water_efficiency_pct": 57.5, "output_kw_max": 67.8, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009957", "000024", "0", "2012/Mar/27 10:12", "MHS Boilers", "MHS Boilers", "Strata Streamline", "75", "", "2003", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "67.8", "67.8", "", "", "87.7", "78.7", "", "57.5", "", "2", "", "", "102", "1", "2", "60", "6", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.3", "96.2", "", "", "", "", "94.5"]} +{"pcdb_id": 9958, "brand_name": "MHS Boilers", "model_name": "Strata Streamline", "model_qualifier": "47", "winter_efficiency_pct": 87.6, "summer_efficiency_pct": 78.6, "comparative_hot_water_efficiency_pct": 57.4, "output_kw_max": 43.9, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009958", "000024", "0", "2012/Mar/27 10:12", "MHS Boilers", "MHS Boilers", "Strata Streamline", "47", "", "2004", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "43.9", "43.9", "", "", "87.6", "78.6", "", "57.4", "", "2", "", "", "102", "1", "2", "60", "6", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.0", "96.2", "", "", "", "", "94.5"]} +{"pcdb_id": 9960, "brand_name": "Boulter", "model_name": "Camray 5", "model_qualifier": "U 40/65 S", "winter_efficiency_pct": 86.6, "summer_efficiency_pct": 74.9, "comparative_hot_water_efficiency_pct": 54.7, "output_kw_max": 19.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009960", "000041", "0", "2012/Mar/27 10:12", "Boulter Buderus", "Boulter", "Camray 5", "U 40/65 S", "", "2003", "current", "4", "1", "1", "1", "0", "", "", "1", "3", "2", "11.7", "19", "", "", "86.6", "74.9", "", "54.7", "", "2", "", "", "201", "1", "1", "150", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.0", "87.0", "", "", "", "", "87.0"]} +{"pcdb_id": 9961, "brand_name": "Boulter", "model_name": "Camray 5", "model_qualifier": "U 65/90 SB", "winter_efficiency_pct": 85.3, "summer_efficiency_pct": 73.6, "comparative_hot_water_efficiency_pct": 53.7, "output_kw_max": 26.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009961", "000041", "0", "2012/Mar/27 10:12", "Boulter Buderus", "Boulter", "Camray 5", "U 65/90 SB", "", "2003", "current", "4", "1", "1", "1", "0", "", "", "1", "3", "2", "19", "26.4", "", "", "85.3", "73.6", "", "53.7", "", "2", "", "", "201", "1", "1", "150", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "84.8", "85.7", "", "", "", "", "85.6"]} +{"pcdb_id": 9962, "brand_name": "Boulter", "model_name": "Camray 5", "model_qualifier": "U 95 / 130 SA", "winter_efficiency_pct": 86.4, "summer_efficiency_pct": 74.7, "comparative_hot_water_efficiency_pct": 54.6, "output_kw_max": 38.1, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009962", "000041", "0", "2012/Mar/27 10:12", "Boulter Buderus", "Boulter", "Camray 5", "U 95 / 130 SA", "", "2003", "current", "4", "1", "1", "1", "0", "", "", "1", "3", "2", "27.8", "38.1", "", "", "86.4", "74.7", "", "54.6", "", "2", "", "", "201", "1", "1", "150", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.0", "86.8", "", "", "", "", "86.6"]} +{"pcdb_id": 9963, "brand_name": "Boulter", "model_name": "Camray 5", "model_qualifier": "40/65 EX", "winter_efficiency_pct": 86.6, "summer_efficiency_pct": 74.9, "comparative_hot_water_efficiency_pct": 54.7, "output_kw_max": 19.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009963", "000041", "0", "2012/Mar/27 10:12", "Boulter Buderus", "Boulter", "Camray 5", "40/65 EX", "", "2003", "current", "4", "1", "2", "1", "0", "", "", "1", "1", "2", "11.7", "19", "", "", "86.6", "74.9", "", "54.7", "", "2", "", "", "201", "1", "1", "150", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.0", "87.0", "", "", "", "", "87.0"]} +{"pcdb_id": 9964, "brand_name": "Boulter", "model_name": "Camray 5", "model_qualifier": "Combi 90BE", "winter_efficiency_pct": 84.0, "summer_efficiency_pct": 74.5, "comparative_hot_water_efficiency_pct": 52.4, "output_kw_max": 26.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009964", "000041", "0", "2004/Jan/28 10:27", "Boulter Buderus", "Boulter", "Camray 5", "Combi 90BE", "", "2003", "current", "4", "1", "2", "2", "0", "", "", "1", "1", "2", "26.4", "26.4", "", "", "84.0", "74.5", "", "52.4", "", "2", "", "", "202", "1", "1", "150", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.2", "86.4", "", "", "", "", "86.2"]} +{"pcdb_id": 9965, "brand_name": "Boulter", "model_name": "Camray 5", "model_qualifier": "65/90 EX", "winter_efficiency_pct": 85.8, "summer_efficiency_pct": 74.1, "comparative_hot_water_efficiency_pct": 54.1, "output_kw_max": 26.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009965", "000041", "0", "2012/Mar/27 10:12", "Boulter Buderus", "Boulter", "Camray 5", "65/90 EX", "", "2003", "current", "4", "1", "2", "1", "0", "", "", "1", "1", "2", "19", "26.4", "", "", "85.8", "74.1", "", "54.1", "", "2", "", "", "201", "1", "1", "150", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.2", "86.4", "", "", "", "", "86.2"]} +{"pcdb_id": 9966, "brand_name": "Saunier Duval", "model_name": "Thema Classic F35E", "model_qualifier": "", "winter_efficiency_pct": 79.5, "summer_efficiency_pct": 69.4, "comparative_hot_water_efficiency_pct": 48.8, "output_kw_max": 34.8, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009966", "000206", "0", "2006/Jan/17 12:31", "Hepworth Heating", "Saunier Duval", "Thema Classic F35E", "", "GC 47-920-40", "2003", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "34.8", "34.8", "", "", "79.5", "69.4", "", "48.8", "", "2", "", "", "104", "1", "2", "130", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.9", "79.5", "", "", "", "", "79.9"]} +{"pcdb_id": 9967, "brand_name": "Glow-worm", "model_name": "35ci", "model_qualifier": "", "winter_efficiency_pct": 79.5, "summer_efficiency_pct": 69.4, "comparative_hot_water_efficiency_pct": 48.8, "output_kw_max": 34.8, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009967", "000207", "0", "2006/Jan/17 12:31", "Hepworth Heating", "Glow-worm", "35ci", "", "GC 47-047-20", "2003", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "34.8", "34.8", "", "", "79.5", "69.4", "", "48.8", "", "2", "", "", "104", "1", "2", "130", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.9", "79.5", "", "", "", "", "79.9"]} +{"pcdb_id": 9968, "brand_name": "Glow-worm", "model_name": "12hxi", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 12.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009968", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "12hxi", "", "GC 41-047-73", "2004", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "12.0", "12.0", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "60", "15", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.7", "96.5", "", "", "", "", "95.0"]} +{"pcdb_id": 9969, "brand_name": "Glow-worm", "model_name": "15hxi", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 15.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009969", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "15hxi", "", "GC 41-047-74", "2004", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "15.0", "15.0", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "60", "15", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0085", "", "", "", "", "", "", "", "", "88.6", "96.5", "", "", "", "", "95.0"]} +{"pcdb_id": 9970, "brand_name": "Glow-worm", "model_name": "18sxi", "model_qualifier": "", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 78.9, "comparative_hot_water_efficiency_pct": 57.6, "output_kw_max": 18.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009970", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "18sxi", "", "GC 41-047-72", "2004", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18.0", "18.0", "", "", "87.9", "78.9", "", "57.6", "", "2", "", "", "102", "1", "2", "180", "15", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.6", "96.3", "", "", "", "", "94.8"]} +{"pcdb_id": 9971, "brand_name": "Glow-worm", "model_name": "24hxi", "model_qualifier": "", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 24.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009971", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "24hxi", "", "GC 41-047-69", "2004", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24.0", "24.0", "", "", "88.2", "79.2", "", "57.9", "", "2", "", "", "102", "1", "2", "60", "15", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.7", "97.0", "", "", "", "", "95.4"]} +{"pcdb_id": 9973, "brand_name": "Fagor Electrodomesticos S.Coop", "model_name": "FE-24E Supercompact", "model_qualifier": "Fe-24EUK", "winter_efficiency_pct": 80.9, "summer_efficiency_pct": 70.8, "comparative_hot_water_efficiency_pct": 49.8, "output_kw_max": 23.7, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009973", "000219", "0", "2013/Jun/25 14:29", "Fagor Electrodomesticos S.Coop", "Fagor Electrodomesticos S.Coop", "FE-24E Supercompact", "Fe-24EUK", "912111011", "2003", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "23.7", "23.7", "", "", "80.9", "70.8", "", "49.8", "", "2", "", "", "104", "1", "2", "30", "4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "0", "", "0004", "", "", "", "", "", "", "", "", "82.1", "82.2", "", "", "", "", "82.2"]} +{"pcdb_id": 9974, "brand_name": "Fagor Electrodomesticos S.Coop", "model_name": "FE-24E Supercompact", "model_qualifier": "FE-24EUK N", "winter_efficiency_pct": 80.9, "summer_efficiency_pct": 70.8, "comparative_hot_water_efficiency_pct": 49.8, "output_kw_max": 23.7, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009974", "000219", "0", "2013/Jun/25 14:29", "Fagor Electrodomesticos S.Coop", "Fagor Electrodomesticos S.Coop", "FE-24E Supercompact", "FE-24EUK N", "912110879", "2003", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "23.7", "23.7", "", "", "80.9", "70.8", "", "49.8", "", "2", "", "", "104", "1", "2", "30", "4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "0", "", "0004", "", "", "", "", "", "", "", "", "82.1", "82.2", "", "", "", "", "82.2"]} +{"pcdb_id": 9976, "brand_name": "Fagor Electrodomesticos S.Coop", "model_name": "FE-24E Supercompact", "model_qualifier": "FE-24EUK", "winter_efficiency_pct": 83.0, "summer_efficiency_pct": 72.9, "comparative_hot_water_efficiency_pct": 51.3, "output_kw_max": 23.7, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009976", "000219", "0", "2013/Jun/25 14:29", "Fagor Electrodomesticos S.Coop", "Fagor Electrodomesticos S.Coop", "FE-24E Supercompact", "FE-24EUK", "912111039", "2003", "current", "2", "2", "1", "2", "0", "", "", "1", "2", "2", "23.7", "23.7", "", "", "83.0", "72.9", "", "51.3", "", "2", "0", "", "104", "1", "2", "30", "4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "0", "", "0004", "", "", "", "", "", "", "", "", "84.6", "87.0", "", "", "", "", "86.6"]} +{"pcdb_id": 9977, "brand_name": "Fagor Electrodomesticos S.Coop", "model_name": "FEE-35MA Supercompact", "model_qualifier": "FEE-35MAUK N", "winter_efficiency_pct": 80.9, "summer_efficiency_pct": 70.8, "comparative_hot_water_efficiency_pct": 55.3, "output_kw_max": 34.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009977", "000219", "0", "2013/Jun/25 14:30", "Fagor Electrodomesticos S.Coop", "Fagor Electrodomesticos S.Coop", "FEE-35MA Supercompact", "FEE-35MAUK N", "912110913", "2003", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "34.5", "34.5", "", "", "80.9", "70.8", "", "55.3", "", "2", "", "", "104", "1", "2", "65", "10", "0", "", "", "2.5", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "", "0004", "", "", "", "", "", "", "", "", "83.1", "81.4", "", "", "", "", "81.7"]} +{"pcdb_id": 9978, "brand_name": "Fagor Electrodomesticos S.Coop", "model_name": "FEE-35MA Supercompact", "model_qualifier": "FEE-35MAUK", "winter_efficiency_pct": 82.7, "summer_efficiency_pct": 72.6, "comparative_hot_water_efficiency_pct": 56.7, "output_kw_max": 34.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009978", "000219", "0", "2013/Jun/25 14:30", "Fagor Electrodomesticos S.Coop", "Fagor Electrodomesticos S.Coop", "FEE-35MA Supercompact", "FEE-35MAUK", "912111057", "2003", "current", "2", "2", "1", "2", "0", "", "", "1", "2", "2", "34.5", "34.5", "", "", "82.7", "72.6", "", "56.7", "", "2", "0", "", "104", "1", "2", "65", "10", "0", "", "", "2.5", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "", "0004", "", "", "", "", "", "", "", "", "84.1", "86.4", "", "", "", "", "86.0"]} +{"pcdb_id": 9979, "brand_name": "Fagor Electrodomesticos S.Coop", "model_name": "FE-27E Supercompact", "model_qualifier": "FE-27EUK N", "winter_efficiency_pct": 79.3, "summer_efficiency_pct": 69.2, "comparative_hot_water_efficiency_pct": 48.7, "output_kw_max": 27.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009979", "000219", "0", "2013/Jun/25 14:30", "Fagor Electrodomesticos S.Coop", "Fagor Electrodomesticos S.Coop", "FE-27E Supercompact", "FE-27EUK N", "912110897", "2003", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "27", "27", "", "", "79.3", "69.2", "", "48.7", "", "2", "", "", "104", "1", "2", "30", "4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "0", "", "0004", "", "", "", "", "", "", "", "", "81.5", "79.6", "", "", "", "", "79.9"]} +{"pcdb_id": 9980, "brand_name": "Fagor Electrodomesticos S.Coop", "model_name": "FE-27E Supercompact", "model_qualifier": "FE-27EUK", "winter_efficiency_pct": 80.7, "summer_efficiency_pct": 70.6, "comparative_hot_water_efficiency_pct": 49.6, "output_kw_max": 27.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009980", "000219", "0", "2013/Jun/25 14:31", "Fagor Electrodomesticos S.Coop", "Fagor Electrodomesticos S.Coop", "FE-27E Supercompact", "FE-27EUK", "912111048", "2003", "current", "2", "2", "1", "2", "0", "", "", "1", "2", "2", "27", "27", "", "", "80.7", "70.6", "", "49.6", "", "2", "0", "", "104", "1", "2", "1", "30", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.9", "80.9", "", "", "", "", "81.2"]} +{"pcdb_id": 9981, "brand_name": "Ferroli", "model_name": "Maxima", "model_qualifier": "35S", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 34.6, "final_year_of_manufacture": 2008, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009981", "000097", "0", "2012/Mar/27 10:12", "Ferroli SpA", "Ferroli", "Maxima", "35S", "", "2004", "2008", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "34.6", "34.6", "", "", "88.9", "79.9", "", "58.3", "", "2", "", "", "102", "1", "2", "150", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.6", "98.3", "", "", "", "", "96.7"]} +{"pcdb_id": 9983, "brand_name": "Potterton", "model_name": "Paramount 60", "model_qualifier": "Natural Gas", "winter_efficiency_pct": 87.8, "summer_efficiency_pct": 78.8, "comparative_hot_water_efficiency_pct": 57.5, "output_kw_max": 59.5, "final_year_of_manufacture": 2010, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009983", "000238", "0", "2012/Mar/27 10:12", "August Brötje GmbH", "Potterton", "Paramount 60", "Natural Gas", "", "2002", "2010", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "59.5", "59.5", "", "", "87.8", "78.8", "", "57.5", "", "2", "", "", "102", "1", "2", "75", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.3", "96.5", "", "", "", "", "94.8"]} +{"pcdb_id": 9984, "brand_name": "Potterton", "model_name": "Paramount 40", "model_qualifier": "Natural Gas", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 78.9, "comparative_hot_water_efficiency_pct": 57.6, "output_kw_max": 39.0, "final_year_of_manufacture": 2010, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009984", "000238", "0", "2012/Mar/27 10:12", "August Brötje GmbH", "Potterton", "Paramount 40", "Natural Gas", "", "2002", "2010", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "39", "39", "", "", "87.9", "78.9", "", "57.6", "", "2", "", "", "102", "1", "2", "60", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.2", "96.8", "", "", "", "", "95.0"]} +{"pcdb_id": 9985, "brand_name": "Sabre", "model_name": "28", "model_qualifier": "LPG", "winter_efficiency_pct": 82.7, "summer_efficiency_pct": 72.6, "comparative_hot_water_efficiency_pct": 51.1, "output_kw_max": 28.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009985", "000011", "0", "2006/Jan/17 12:31", "Vokera", "Sabre", "28", "LPG", "829", "2004", "current", "2", "2", "1", "2", "0", "", "", "1", "2", "2", "28.0", "28.0", "", "", "82.7", "72.6", "", "51.1", "", "2", "0", "", "104", "1", "2", "125", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "84.5", "83.4", "", "", "", "", "83.6"]} +{"pcdb_id": 9986, "brand_name": "Sabre", "model_name": "24", "model_qualifier": "LPG", "winter_efficiency_pct": 83.1, "summer_efficiency_pct": 73.0, "comparative_hot_water_efficiency_pct": 51.3, "output_kw_max": 24.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009986", "000011", "0", "2006/Jan/17 12:31", "Vokera", "Sabre", "24", "LPG", "827", "2004", "current", "2", "2", "1", "2", "0", "", "", "1", "2", "2", "24.0", "24.0", "", "", "83.1", "73.0", "", "51.3", "", "2", "0", "", "104", "1", "2", "125", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "84.9", "83.8", "", "", "", "", "84.0"]} +{"pcdb_id": 9987, "brand_name": "Sabre", "model_name": "24", "model_qualifier": "", "winter_efficiency_pct": 81.4, "summer_efficiency_pct": 71.3, "comparative_hot_water_efficiency_pct": 50.1, "output_kw_max": 24.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009987", "000011", "0", "2006/Jan/17 12:31", "Vokera", "Sabre", "24", "", "826", "2004", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "24.0", "24.0", "", "", "81.4", "71.3", "", "50.1", "", "2", "", "", "104", "1", "2", "125", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "83.3", "82.3", "", "", "", "", "82.4"]} +{"pcdb_id": 9988, "brand_name": "Sabre", "model_name": "28", "model_qualifier": "", "winter_efficiency_pct": 81.3, "summer_efficiency_pct": 71.2, "comparative_hot_water_efficiency_pct": 50.1, "output_kw_max": 28.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009988", "000011", "0", "2006/Jan/17 12:31", "Vokera", "Sabre", "28", "", "828", "2004", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "28.0", "28.0", "", "", "81.3", "71.2", "", "50.1", "", "2", "", "", "104", "1", "2", "125", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "83.3", "82.2", "", "", "", "", "82.4"]} +{"pcdb_id": 9989, "brand_name": "Glow-worm", "model_name": "30cxi", "model_qualifier": "", "winter_efficiency_pct": 90.1, "summer_efficiency_pct": 81.5, "comparative_hot_water_efficiency_pct": 57.3, "output_kw_max": 22.94, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009989", "000207", "0", "2015/Jul/14 11:39", "Hepworth Heating", "Glow-worm", "30cxi", "", "GC 47-047-24", "2002", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "22.94", "22.94", "", "", "90.1", "81.5", "", "57.3", "", "2", "0", "", "104", "1", "2", "180", "15", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.1", "99.0", "", "", "", "", "97.3"]} +{"pcdb_id": 9990, "brand_name": "Glow-worm", "model_name": "30hxi", "model_qualifier": "", "winter_efficiency_pct": 90.0, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 59.2, "output_kw_max": 28.17, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009990", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "30hxi", "", "GC 41-047-64", "2002", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "28.17", "28.17", "", "", "90.0", "81.0", "", "59.2", "", "2", "0", "", "102", "1", "2", "60", "15", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.8", "99.0", "", "", "", "", "97.3"]} +{"pcdb_id": 9991, "brand_name": "Firebird", "model_name": "Heatpac 70", "model_qualifier": "", "winter_efficiency_pct": 85.0, "summer_efficiency_pct": 73.3, "comparative_hot_water_efficiency_pct": 53.6, "output_kw_max": 20.52, "final_year_of_manufacture": 2013, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009991", "000047", "0", "2018/Jan/03 14:39", "Firebird Boilers", "Firebird", "Heatpac 70", "", "", "2004", "2013", "4", "1", "2", "1", "0", "", "", "1", "1", "1", "14.65", "20.52", "", "", "85.0", "73.3", "", "53.6", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.5", "84.6", "", "", "", "", "84.8"]} +{"pcdb_id": 9992, "brand_name": "Firebird", "model_name": "S (White Cased) 70 System", "model_qualifier": "", "winter_efficiency_pct": 85.0, "summer_efficiency_pct": 73.3, "comparative_hot_water_efficiency_pct": 53.6, "output_kw_max": 20.52, "final_year_of_manufacture": 2013, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009992", "000047", "0", "2018/Jan/03 14:41", "Firebird Boilers", "Firebird", "S (White Cased) 70 System", "", "", "2004", "2013", "4", "1", "1", "1", "0", "", "", "1", "2", "1", "14.65", "20.52", "", "", "85.0", "73.3", "", "53.6", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.5", "84.6", "", "", "", "", "84.8"]} +{"pcdb_id": 9993, "brand_name": "Firebird", "model_name": "Heatpac 70 System", "model_qualifier": "", "winter_efficiency_pct": 85.0, "summer_efficiency_pct": 73.3, "comparative_hot_water_efficiency_pct": 53.6, "output_kw_max": 20.52, "final_year_of_manufacture": 2013, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009993", "000047", "0", "2018/Jan/03 14:43", "Firebird Boilers", "Firebird", "Heatpac 70 System", "", "", "2004", "2013", "4", "1", "2", "1", "0", "", "", "1", "1", "1", "14.65", "20.52", "", "", "85.0", "73.3", "", "53.6", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.5", "84.6", "", "", "", "", "84.8"]} +{"pcdb_id": 9994, "brand_name": "Firebird", "model_name": "Heatpac 90-120 System", "model_qualifier": "", "winter_efficiency_pct": 86.4, "summer_efficiency_pct": 74.7, "comparative_hot_water_efficiency_pct": 54.6, "output_kw_max": 35.17, "final_year_of_manufacture": 2013, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009994", "000047", "0", "2018/Jan/03 14:44", "Firebird Boilers", "Firebird", "Heatpac 90-120 System", "", "", "2004", "2013", "4", "1", "2", "1", "0", "", "", "1", "1", "1", "26.38", "35.17", "", "", "86.4", "74.7", "", "54.6", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.4", "86.7", "", "", "", "", "86.6"]} +{"pcdb_id": 9995, "brand_name": "Firebird", "model_name": "S (White Cased) 90-120 System", "model_qualifier": "", "winter_efficiency_pct": 86.4, "summer_efficiency_pct": 74.7, "comparative_hot_water_efficiency_pct": 54.6, "output_kw_max": 35.17, "final_year_of_manufacture": 2013, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009995", "000047", "0", "2018/Jan/03 14:48", "Firebird Boilers", "Firebird", "S (White Cased) 90-120 System", "", "", "2004", "2013", "4", "1", "1", "1", "0", "", "", "1", "2", "1", "26.38", "35.17", "", "", "86.4", "74.7", "", "54.6", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.4", "86.7", "", "", "", "", "86.6"]} +{"pcdb_id": 9996, "brand_name": "Ferroli", "model_name": "SYS 10-23", "model_qualifier": "", "winter_efficiency_pct": 79.8, "summer_efficiency_pct": 69.7, "comparative_hot_water_efficiency_pct": 50.9, "output_kw_max": 23.3, "final_year_of_manufacture": 2006, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009996", "000097", "0", "2012/Mar/27 10:12", "Ferroli SpA", "Ferroli", "SYS 10-23", "", "", "2003", "2006", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "9.7", "23.3", "", "", "79.8", "69.7", "", "50.9", "", "2", "", "", "101", "1", "1", "125", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "82.0", "80.7", "", "", "", "", "81.0"]} +{"pcdb_id": 9997, "brand_name": "Worcester", "model_name": "Greenstar R", "model_qualifier": "29 HE Conventional", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 27.7, "final_year_of_manufacture": 2006, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009997", "000035", "0", "2020/Sep/04 08:07", "Worcester Heat Systems", "Worcester", "Greenstar R", "29 HE Conventional", "ZB 11-28 HE", "2003", "2006", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "27.7", "27.7", "", "", "89.1", "80.1", "", "58.5", "", "2", "1", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.9", "98.9", "", "", "", "", "97.4"]} +{"pcdb_id": 9998, "brand_name": "Worcester", "model_name": "Greenstar R", "model_qualifier": "40 HE Conventional", "winter_efficiency_pct": 89.3, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 58.7, "output_kw_max": 40.0, "final_year_of_manufacture": 2006, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009998", "000035", "0", "2020/Sep/04 08:07", "Worcester Heat Systems", "Worcester", "Greenstar R", "40 HE Conventional", "ZB 14-40 HE", "2003", "2006", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "40.0", "40.0", "", "", "89.3", "80.3", "", "58.7", "", "2", "1", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.8", "99.8", "", "", "", "", "97.9"]} +{"pcdb_id": 9999, "brand_name": "Worcester", "model_name": "Greenstar R", "model_qualifier": "25 HE Combi", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.4, "comparative_hot_water_efficiency_pct": 56.6, "output_kw_max": 27.5, "final_year_of_manufacture": 2006, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["009999", "000035", "0", "2020/Sep/04 08:07", "Worcester Heat Systems", "Worcester", "Greenstar R", "25 HE Combi", "ZWB 11-25 HE", "2003", "2006", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "27.5", "27.5", "", "", "89.0", "80.4", "", "56.6", "", "2", "1", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.9", "98.6", "", "", "", "", "97.2"]} +{"pcdb_id": 10000, "brand_name": "Worcester", "model_name": "Greenstar R", "model_qualifier": "28 HE System", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 27.7, "final_year_of_manufacture": 2006, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010000", "000035", "0", "2020/Sep/04 08:07", "Worcester Heat Systems", "Worcester", "Greenstar R", "28 HE System", "ZB 11-28 HE", "2003", "2006", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "27.7", "27.7", "", "", "89.1", "80.1", "", "58.5", "", "2", "1", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.9", "98.9", "", "", "", "", "97.4"]} +{"pcdb_id": 10001, "brand_name": "Worcester", "model_name": "Greenstar R", "model_qualifier": "30 HE Combi", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 56.6, "output_kw_max": 29.5, "final_year_of_manufacture": 2006, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010001", "000035", "0", "2020/Sep/04 08:07", "Worcester Heat Systems", "Worcester", "Greenstar R", "30 HE Combi", "ZWB 11-30 HE", "2003", "2006", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "29.5", "29.5", "", "", "89.1", "80.5", "", "56.6", "", "2", "1", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.9", "98.9", "", "", "", "", "97.4"]} +{"pcdb_id": 10002, "brand_name": "Worcester", "model_name": "Greenstar R", "model_qualifier": "30 HE Plus Combi", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 56.6, "output_kw_max": 29.5, "final_year_of_manufacture": 2006, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010002", "000035", "0", "2020/Sep/04 08:07", "Worcester Heat Systems", "Worcester", "Greenstar R", "30 HE Plus Combi", "ZWBR 11-30 HE", "2003", "2006", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "29.5", "29.5", "", "", "89.1", "80.5", "", "56.6", "", "2", "1", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.9", "98.9", "", "", "", "", "97.4"]} +{"pcdb_id": 10003, "brand_name": "Worcester", "model_name": "Greenstar R", "model_qualifier": "35 HE plus Combi", "winter_efficiency_pct": 89.9, "summer_efficiency_pct": 81.3, "comparative_hot_water_efficiency_pct": 57.2, "output_kw_max": 35.5, "final_year_of_manufacture": 2006, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010003", "000035", "0", "2020/Sep/04 08:07", "Worcester Heat Systems", "Worcester", "Greenstar R", "35 HE plus Combi", "ZWBR 14-35 HE", "2003", "2006", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "35.5", "35.5", "", "", "89.9", "81.3", "", "57.2", "", "2", "1", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.4", "101.1", "", "", "", "", "99.1"]} +{"pcdb_id": 10004, "brand_name": "Worcester", "model_name": "Greenstar R", "model_qualifier": "40 HE Plus Combi", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.4, "comparative_hot_water_efficiency_pct": 56.5, "output_kw_max": 40.0, "final_year_of_manufacture": 2006, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010004", "000035", "0", "2020/Sep/04 08:07", "Worcester Heat Systems", "Worcester", "Greenstar R", "40 HE Plus Combi", "ZB 14-40 HE", "2003", "2006", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "40.0", "40.0", "", "", "89.0", "80.4", "", "56.5", "", "2", "1", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.8", "98.9", "", "", "", "", "97.2"]} +{"pcdb_id": 10005, "brand_name": "British Gas", "model_name": "RD 428", "model_qualifier": "", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 27.7, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010005", "000035", "0", "2012/Mar/27 10:12", "Worcester Heat Systems", "British Gas", "RD 428", "", "ZB 11-18 RD", "2003", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "27.7", "27.7", "", "", "89.1", "80.1", "", "58.5", "", "2", "1", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.9", "98.9", "", "", "", "", "97.4"]} +{"pcdb_id": 10006, "brand_name": "Nefit Buderus Ltd", "model_name": "Boulter Buderus", "model_qualifier": "600-28C", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 56.5, "output_kw_max": 23.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010006", "000041", "0", "2013/Jun/25 14:36", "Nefit Buderus", "Nefit Buderus Ltd", "Boulter Buderus", "600-28C", "47-110-02", "2003", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "23", "23", "", "", "88.9", "80.3", "", "56.5", "", "2", "", "", "104", "1", "2", "120", "6.5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.2", "99.1", "", "", "", "", "97.0"]} +{"pcdb_id": 10007, "brand_name": "Ariston", "model_name": "Microgenus II 24 MFFI", "model_qualifier": "", "winter_efficiency_pct": 82.9, "summer_efficiency_pct": 72.8, "comparative_hot_water_efficiency_pct": 51.2, "output_kw_max": 24.8, "final_year_of_manufacture": 2007, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010007", "000080", "0", "2007/Nov/07 09:11", "Merloni TermoSanitari SpA", "Ariston", "Microgenus II 24 MFFI", "", "", "2004", "2007", "2", "2", "1", "2", "0", "", "", "1", "2", "2", "24.8", "24.8", "", "", "82.9", "72.8", "", "51.2", "", "2", "1", "", "104", "1", "2", "120", "7", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "86.3", "83.5", "", "", "", "", "84.1"]} +{"pcdb_id": 10008, "brand_name": "Ariston", "model_name": "Microgenus II 28 MFFI", "model_qualifier": "", "winter_efficiency_pct": 82.3, "summer_efficiency_pct": 72.2, "comparative_hot_water_efficiency_pct": 50.8, "output_kw_max": 28.0, "final_year_of_manufacture": 2007, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010008", "000080", "0", "2007/Nov/07 09:13", "Merloni TermoSanitari SpA", "Ariston", "Microgenus II 28 MFFI", "", "", "2004", "2007", "2", "2", "1", "2", "0", "", "", "1", "2", "2", "28", "28", "", "", "82.3", "72.2", "", "50.8", "", "2", "1", "", "104", "1", "2", "140", "7", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "85.8", "82.3", "", "", "", "", "83.0"]} +{"pcdb_id": 10009, "brand_name": "Ariston", "model_name": "Microgenus II 31 MFFI", "model_qualifier": "", "winter_efficiency_pct": 82.6, "summer_efficiency_pct": 72.5, "comparative_hot_water_efficiency_pct": 51.0, "output_kw_max": 31.1, "final_year_of_manufacture": 2007, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010009", "000080", "0", "2007/Nov/07 09:12", "Merloni TermoSanitari SpA", "Ariston", "Microgenus II 31 MFFI", "", "", "2004", "2007", "2", "2", "1", "2", "0", "", "", "1", "2", "2", "31.1", "31.1", "", "", "82.6", "72.5", "", "51.0", "", "2", "1", "", "104", "1", "2", "140", "7", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "85.5", "82.9", "", "", "", "", "83.4"]} +{"pcdb_id": 10010, "brand_name": "Ariston", "model_name": "Microgenus II 24 MFFI", "model_qualifier": "", "winter_efficiency_pct": 81.1, "summer_efficiency_pct": 71.0, "comparative_hot_water_efficiency_pct": 49.9, "output_kw_max": 24.8, "final_year_of_manufacture": 2007, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010010", "000080", "0", "2007/Nov/07 09:11", "Merloni TermoSanitari SpA", "Ariston", "Microgenus II 24 MFFI", "", "GC No 47-116-25", "2004", "2007", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "24.8", "24.8", "", "", "81.1", "71.0", "", "49.9", "", "2", "", "", "104", "1", "2", "120", "7", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "84.4", "81.7", "", "", "", "", "82.2"]} +{"pcdb_id": 10011, "brand_name": "Ariston", "model_name": "Microgenus II 28 MFFI", "model_qualifier": "", "winter_efficiency_pct": 80.5, "summer_efficiency_pct": 70.4, "comparative_hot_water_efficiency_pct": 49.5, "output_kw_max": 28.0, "final_year_of_manufacture": 2007, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010011", "000080", "0", "2007/Nov/07 09:13", "Merloni TermoSanitari SpA", "Ariston", "Microgenus II 28 MFFI", "", "GC No 47-116-26", "2004", "2007", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "28", "28", "", "", "80.5", "70.4", "", "49.5", "", "2", "", "", "104", "1", "2", "140", "7", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "84.0", "80.5", "", "", "", "", "81.2"]} +{"pcdb_id": 10012, "brand_name": "Ariston", "model_name": "Microgenus II 31 MFFI", "model_qualifier": "", "winter_efficiency_pct": 80.8, "summer_efficiency_pct": 70.7, "comparative_hot_water_efficiency_pct": 49.7, "output_kw_max": 31.1, "final_year_of_manufacture": 2007, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010012", "000080", "0", "2007/Nov/07 09:12", "Merloni TermoSanitari SpA", "Ariston", "Microgenus II 31 MFFI", "", "GC No 47-116-27", "2004", "2007", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "31.1", "31.1", "", "", "80.8", "70.7", "", "49.7", "", "2", "", "", "104", "1", "2", "140", "7", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "83.6", "81.1", "", "", "", "", "81.6"]} +{"pcdb_id": 10013, "brand_name": "HRM Boilers", "model_name": "Weybourne", "model_qualifier": "70/95", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 27.8, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010013", "000098", "0", "2012/Mar/27 10:12", "HRM Boilers", "HRM Boilers", "Weybourne", "70/95", "", "2003", "current", "4", "1", "1", "1", "0", "", "", "1", "3", "2", "20", "27.8", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "140", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.7", "87.3", "", "", "", "", "87.4"]} +{"pcdb_id": 10014, "brand_name": "HRM Boilers", "model_name": "Weybourne", "model_qualifier": "50/70", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 20.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010014", "000098", "0", "2012/Mar/27 10:12", "HRM Boilers", "HRM Boilers", "Weybourne", "50/70", "", "2003", "current", "4", "1", "1", "1", "0", "", "", "1", "3", "2", "15", "20", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "140", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.8", "87.7", "", "", "", "", "87.7"]} +{"pcdb_id": 10015, "brand_name": "HRM Boilers", "model_name": "Wallstar System", "model_qualifier": "15/20 System 12", "winter_efficiency_pct": 86.4, "summer_efficiency_pct": 74.7, "comparative_hot_water_efficiency_pct": 54.6, "output_kw_max": 20.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010015", "000098", "0", "2012/Mar/27 10:12", "HRM Boilers", "HRM Boilers", "Wallstar System", "15/20 System 12", "", "2003", "current", "4", "2", "1", "1", "0", "", "", "1", "2", "2", "15", "20", "", "", "86.4", "74.7", "", "54.6", "", "2", "", "", "201", "1", "1", "215", "75", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.6", "86.6", "", "", "", "", "86.6"]} +{"pcdb_id": 10016, "brand_name": "Evo", "model_name": "HE 16", "model_qualifier": "HE16", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 14.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010016", "000008", "0", "2012/Mar/27 10:12", "Ideal Boilers", "Evo", "HE 16", "HE16", "", "2003", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "14.6", "14.6", "", "", "89.0", "80.0", "", "58.4", "", "2", "", "", "102", "1", "2", "38", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.5", "99.0", "", "", "", "", "97.0"]} +{"pcdb_id": 10017, "brand_name": "Evo", "model_name": "HE 19", "model_qualifier": "HE19", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 18.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010017", "000008", "0", "2012/Mar/27 10:12", "Ideal Boilers", "Evo", "HE 19", "HE19", "", "2003", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18.2", "18.2", "", "", "88.7", "79.7", "", "58.2", "", "2", "", "", "102", "1", "2", "148", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.2", "98.5", "", "", "", "", "96.5"]} +{"pcdb_id": 10018, "brand_name": "Evo", "model_name": "HE 22", "model_qualifier": "HE22", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 23.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010018", "000008", "0", "2012/Mar/27 10:12", "Ideal Boilers", "Evo", "HE 22", "HE22", "", "2003", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "23.4", "23.4", "", "", "88.1", "79.1", "", "57.8", "", "2", "", "", "102", "1", "2", "38", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "97.1", "", "", "", "", "95.4"]} +{"pcdb_id": 10019, "brand_name": "Evo", "model_name": "HE C22/24", "model_qualifier": "HE C 22/24", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 55.9, "output_kw_max": 23.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010019", "000008", "0", "2006/Jan/17 12:31", "Ideal Boilers", "Evo", "HE C22/24", "HE C 22/24", "", "2003", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "23.4", "23.4", "", "", "88.1", "79.5", "", "55.9", "", "2", "", "", "104", "1", "2", "148", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "97.1", "", "", "", "", "95.4"]} +{"pcdb_id": 10020, "brand_name": "Evo", "model_name": "HE C22/35", "model_qualifier": "HE C22/35", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 55.9, "output_kw_max": 23.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010020", "000008", "0", "2006/Jan/17 12:31", "Ideal Boilers", "Evo", "HE C22/35", "HE C22/35", "", "2003", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "23.4", "23.4", "", "", "88.1", "79.5", "", "55.9", "", "2", "", "", "104", "1", "2", "148", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "97.1", "", "", "", "", "95.4"]} +{"pcdb_id": 10021, "brand_name": "DD Heating", "model_name": "Heatline", "model_qualifier": "S20S Compact", "winter_efficiency_pct": 80.4, "summer_efficiency_pct": 69.7, "comparative_hot_water_efficiency_pct": 50.9, "output_kw_max": 21.1, "final_year_of_manufacture": 2007, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010021", "000215", "0", "2012/Mar/27 10:12", "Turk Demir Dokum Fab AS", "DD Heating", "Heatline", "S20S Compact", "", "2003", "2007", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "21.1", "21.1", "", "", "80.4", "69.7", "", "50.9", "", "2", "", "", "102", "1", "2", "159", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "83.9", "79.8", "", "", "", "", "80.6"]} +{"pcdb_id": 10022, "brand_name": "DD Heating", "model_name": "Heatline", "model_qualifier": "S24S Compact", "winter_efficiency_pct": 81.0, "summer_efficiency_pct": 70.3, "comparative_hot_water_efficiency_pct": 51.4, "output_kw_max": 25.1, "final_year_of_manufacture": 2007, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010022", "000215", "0", "2012/Mar/27 10:12", "Turk Demir Dokum Fab AS", "DD Heating", "Heatline", "S24S Compact", "", "2003", "2007", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "25.1", "25.1", "", "", "81.0", "70.3", "", "51.4", "", "2", "", "", "102", "1", "2", "159", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "84.1", "81.2", "", "", "", "", "81.7"]} +{"pcdb_id": 10023, "brand_name": "DD Heating", "model_name": "Heatline", "model_qualifier": "S30S Compact", "winter_efficiency_pct": 80.1, "summer_efficiency_pct": 69.4, "comparative_hot_water_efficiency_pct": 50.7, "output_kw_max": 30.1, "final_year_of_manufacture": 2007, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010023", "000215", "0", "2012/Mar/27 10:12", "Turk Demir Dokum Fab AS", "DD Heating", "Heatline", "S30S Compact", "", "2003", "2007", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "30.1", "30.1", "", "", "80.1", "69.4", "", "50.7", "", "2", "", "", "102", "1", "2", "159", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "84.3", "79.3", "", "", "", "", "80.2"]} +{"pcdb_id": 10024, "brand_name": "Ariston", "model_name": "Genus Plus 30 BFFI", "model_qualifier": "", "winter_efficiency_pct": 81.8, "summer_efficiency_pct": 72.7, "comparative_hot_water_efficiency_pct": 42.0, "output_kw_max": 30.0, "final_year_of_manufacture": 2007, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010024", "000080", "0", "2024/Jan/31 10:17", "Chaffoteaux & Maury", "Ariston", "Genus Plus 30 BFFI", "", "GC No. 47-116-28", "2004", "2007", "2", "2", "1", "2", "0", "", "", "1", "2", "2", "30", "30", "", "", "81.8", "72.7", "", "42.0", "", "2", "1", "", "106", "1", "2", "150", "7", "2", "1", "0", "50", "0", "20", "5", "70", "0.68", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "84.6", "80.8", "", "", "", "", "81.5"]} +{"pcdb_id": 10025, "brand_name": "Ariston", "model_name": "Genus Plus 30 BFFI", "model_qualifier": "", "winter_efficiency_pct": 80.0, "summer_efficiency_pct": 70.9, "comparative_hot_water_efficiency_pct": 40.9, "output_kw_max": 30.0, "final_year_of_manufacture": 2007, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010025", "000080", "0", "2024/Jan/31 10:17", "Chaffoteaux et Maury", "Ariston", "Genus Plus 30 BFFI", "", "GC No. 47-116-28", "2004", "2007", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "30", "30", "", "", "80.0", "70.9", "", "40.9", "", "2", "", "", "106", "1", "2", "150", "7", "2", "1", "0", "50", "0", "20", "5", "70", "0.68", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.8", "79.0", "", "", "", "", "79.7"]} +{"pcdb_id": 10026, "brand_name": "Vokera", "model_name": "Synergy", "model_qualifier": "25e", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 78.9, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 24.7, "final_year_of_manufacture": 2010, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010026", "000011", "0", "2012/Mar/27 10:12", "Vokera", "Vokera", "Synergy", "25e", "4109435", "2004", "2010", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24.7", "24.7", "", "", "87.9", "78.9", "", "57.7", "", "2", "", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.0", "96.2", "", "", "", "", "94.9"]} +{"pcdb_id": 10027, "brand_name": "Vokera", "model_name": "Syntesi", "model_qualifier": "25e", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 55.8, "output_kw_max": 24.7, "final_year_of_manufacture": 2010, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010027", "000011", "0", "2010/Oct/21 11:08", "Vokera", "Vokera", "Syntesi", "25e", "4709446", "2003", "2010", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.7", "24.7", "", "", "87.9", "79.3", "", "55.8", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.0", "96.2", "", "", "", "", "94.9"]} +{"pcdb_id": 10028, "brand_name": "Baxi", "model_name": "100/2 HE Plus", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 30.2, "final_year_of_manufacture": 2006, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010028", "000005", "0", "2012/Mar/27 10:12", "Baxi Potterton", "Baxi", "100/2 HE Plus", "", "GC No. 41-075-34", "2004", "2006", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "30.2", "30.2", "", "", "88.1", "79.1", "", "57.8", "", "2", "", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.4", "96.4", "", "", "", "", "95.1"]} +{"pcdb_id": 10029, "brand_name": "Baxi", "model_name": "System", "model_qualifier": "100 HE Plus", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 30.2, "final_year_of_manufacture": 2006, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010029", "000005", "0", "2012/Mar/27 10:12", "Baxi Potterton", "Baxi", "System", "100 HE Plus", "GC No. 41-075-43", "2004", "2006", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "30.2", "30.2", "", "", "88.1", "79.1", "", "57.8", "", "2", "", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.4", "96.4", "", "", "", "", "95.1"]} +{"pcdb_id": 10030, "brand_name": "Baxi", "model_name": "Combi", "model_qualifier": "80 HE Plus", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 56.4, "output_kw_max": 24.1, "final_year_of_manufacture": 2006, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010030", "000005", "0", "2009/Oct/26 16:58", "Baxi Potterton", "Baxi", "Combi", "80 HE Plus", "GC No. 41-075-16", "2004", "2006", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.1", "24.1", "", "", "88.8", "80.2", "", "56.4", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.5", "98.3", "", "", "", "", "96.6"]} +{"pcdb_id": 10031, "brand_name": "Baxi", "model_name": "Combi", "model_qualifier": "100 HE Plus", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 56.4, "output_kw_max": 30.2, "final_year_of_manufacture": 2006, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010031", "000005", "0", "2009/Oct/26 16:57", "Baxi Potterton", "Baxi", "Combi", "100 HE Plus", "GC No. 41-075-15", "2004", "2006", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "30.2", "30.2", "", "", "88.8", "80.2", "", "56.4", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.4", "98.3", "", "", "", "", "96.6"]} +{"pcdb_id": 10032, "brand_name": "Baxi", "model_name": "Combi", "model_qualifier": "133 HE Plus", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 55.9, "output_kw_max": 30.1, "final_year_of_manufacture": 2007, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010032", "000005", "0", "2010/Nov/19 09:01", "Baxi Potterton", "Baxi", "Combi", "133 HE Plus", "GC No. 41-075-14", "2004", "2007", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "30.1", "30.1", "", "", "88.1", "79.5", "", "55.9", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.2", "96.6", "", "", "", "", "95.2"]} +{"pcdb_id": 10033, "brand_name": "British Gas", "model_name": "330", "model_qualifier": "", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 31.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010033", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "British Gas", "330", "", "GC 41-047-75", "2004", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "31.0", "31.0", "", "", "89.0", "80.0", "", "58.4", "", "2", "", "", "102", "1", "2", "60", "15", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.2", "98.8", "", "", "", "", "97.0"]} +{"pcdb_id": 10034, "brand_name": "Ferroli", "model_name": "Optimax", "model_qualifier": "25 S", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 24.7, "final_year_of_manufacture": 2008, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010034", "000097", "0", "2012/Mar/27 10:12", "Ferroli SpA", "Ferroli", "Optimax", "25 S", "", "2003", "2008", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24.7", "24.7", "", "", "88.7", "79.7", "", "58.2", "", "2", "", "", "102", "1", "2", "130", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.4", "98.5", "", "", "", "", "96.6"]} +{"pcdb_id": 10035, "brand_name": "Ferroli", "model_name": "Optimax", "model_qualifier": "25 OV", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 24.7, "final_year_of_manufacture": 2017, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010035", "000097", "0", "2017/Aug/07 16:58", "Ferroli SpA", "Ferroli", "Optimax", "25 OV", "", "2003", "2017", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24.7", "24.7", "", "", "88.7", "79.7", "", "58.2", "", "2", "", "", "102", "1", "2", "60", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.4", "98.5", "", "", "", "", "96.6"]} +{"pcdb_id": 10036, "brand_name": "Ferroli", "model_name": "Optimax", "model_qualifier": "25 C", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 56.3, "output_kw_max": 24.7, "final_year_of_manufacture": 2008, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010036", "000097", "0", "2009/Apr/28 16:03", "Ferroli SpA", "Ferroli", "Optimax", "25 C", "", "2004", "2008", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.7", "24.7", "", "", "88.7", "80.1", "", "56.3", "", "2", "", "", "104", "1", "2", "140", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.4", "98.5", "", "", "", "", "96.6"]} +{"pcdb_id": 10038, "brand_name": "Nefit Buderus Ltd", "model_name": "Boulter Buderus", "model_qualifier": "600/28CP", "winter_efficiency_pct": 90.0, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 59.2, "output_kw_max": 23.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010038", "000041", "0", "2013/Jun/25 14:37", "Nefit Buderus", "Nefit Buderus Ltd", "Boulter Buderus", "600/28CP", "87470174", "2002", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "23.0", "23.0", "", "", "90.0", "81.0", "", "59.2", "", "2", "0", "", "102", "1", "2", "120", "6.5", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.4", "99.2", "", "", "", "", "97.3"]} +{"pcdb_id": 10040, "brand_name": "Johnson & Starley", "model_name": "Reno", "model_qualifier": "HE25HP", "winter_efficiency_pct": 89.7, "summer_efficiency_pct": 80.7, "comparative_hot_water_efficiency_pct": 59.0, "output_kw_max": 27.85, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010040", "000239", "0", "2012/Mar/27 10:12", "Johnson & Starley", "Johnson & Starley", "Reno", "HE25HP", "", "2004", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "27.85", "27.85", "", "", "89.7", "80.7", "", "59.0", "", "2", "0", "", "102", "1", "2", "35", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.1", "98.6", "", "", "", "", "96.8"]} +{"pcdb_id": 10041, "brand_name": "Johnson & Starley", "model_name": "Reno", "model_qualifier": "HE25H", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 25.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010041", "000239", "0", "2012/Mar/27 10:12", "Johnson & Starley", "Johnson & Starley", "Reno", "HE25H", "87B074", "2004", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "25.0", "25.0", "", "", "88.5", "79.5", "", "58.1", "", "2", "", "", "102", "1", "2", "35", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.4", "98.0", "", "", "", "", "96.2"]} +{"pcdb_id": 10042, "brand_name": "Johnson & Starley", "model_name": "Reno", "model_qualifier": "HE25SP", "winter_efficiency_pct": 89.7, "summer_efficiency_pct": 80.7, "comparative_hot_water_efficiency_pct": 59.0, "output_kw_max": 25.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010042", "000239", "0", "2012/Mar/27 10:12", "Johnson & Starley", "Johnson & Starley", "Reno", "HE25SP", "", "2004", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "25.0", "25.0", "", "", "89.7", "80.7", "", "59.0", "", "2", "0", "", "102", "1", "2", "145", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.1", "98.6", "", "", "", "", "96.8"]} +{"pcdb_id": 10043, "brand_name": "Johnson & Starley", "model_name": "Reno", "model_qualifier": "HE25S", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 25.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010043", "000239", "0", "2012/Mar/27 10:12", "Johnson & Starley", "Johnson & Starley", "Reno", "HE25S", "", "2004", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "25.0", "25.0", "", "", "88.5", "79.5", "", "58.1", "", "2", "", "", "102", "1", "2", "145", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.4", "98.0", "", "", "", "", "96.2"]} +{"pcdb_id": 10044, "brand_name": "Johnson & Starley", "model_name": "Reno", "model_qualifier": "HE30CP", "winter_efficiency_pct": 89.7, "summer_efficiency_pct": 81.1, "comparative_hot_water_efficiency_pct": 57.1, "output_kw_max": 25.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010044", "000239", "0", "2010/Sep/29 12:39", "Johnson & Starley", "Johnson & Starley", "Reno", "HE30CP", "", "2004", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "25.0", "25.0", "", "", "89.7", "81.1", "", "57.1", "", "2", "0", "", "104", "1", "2", "145", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.1", "98.6", "", "", "", "", "96.8"]} +{"pcdb_id": 10045, "brand_name": "Johnson & Starley", "model_name": "Reno", "model_qualifier": "HE30C", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 56.2, "output_kw_max": 25.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010045", "000239", "0", "2009/Oct/28 09:38", "Johnson & Starley", "Johnson & Starley", "Reno", "HE30C", "", "2004", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "25.0", "25.0", "", "", "88.5", "79.9", "", "56.2", "", "2", "", "", "104", "1", "2", "145", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.4", "98.0", "", "", "", "", "96.2"]} +{"pcdb_id": 10046, "brand_name": "Biasi", "model_name": "Riva Compact HE", "model_qualifier": "M96.24SM/C", "winter_efficiency_pct": 86.2, "summer_efficiency_pct": 77.6, "comparative_hot_water_efficiency_pct": 54.5, "output_kw_max": 24.1, "final_year_of_manufacture": 2008, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010046", "000208", "0", "2008/May/22 11:25", "Biasi (UK)", "Biasi", "Riva Compact HE", "M96.24SM/C", "", "2004", "2008", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24.10", "24.10", "", "", "86.2", "77.6", "", "54.5", "", "2", "1", "", "104", "1", "2", "140", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.8", "92.2", "", "", "", "", "91.5"]} +{"pcdb_id": 10047, "brand_name": "Biasi", "model_name": "Riva Compact HE", "model_qualifier": "M96.24SM/C", "winter_efficiency_pct": 85.2, "summer_efficiency_pct": 76.6, "comparative_hot_water_efficiency_pct": 53.9, "output_kw_max": 24.1, "final_year_of_manufacture": 2008, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010047", "000208", "0", "2008/May/22 11:25", "Biasi (UK)", "Biasi", "Riva Compact HE", "M96.24SM/C", "47-970-23", "2004", "2008", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.10", "24.10", "", "", "85.2", "76.6", "", "53.9", "", "2", "", "", "104", "1", "2", "140", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "86.9", "90.2", "", "", "", "", "89.6"]} +{"pcdb_id": 10048, "brand_name": "Biasi", "model_name": "Riva Compact HE", "model_qualifier": "M96.28SM/C", "winter_efficiency_pct": 86.1, "summer_efficiency_pct": 77.5, "comparative_hot_water_efficiency_pct": 54.5, "output_kw_max": 27.9, "final_year_of_manufacture": 2008, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010048", "000208", "0", "2008/May/22 11:31", "Biasi (UK)", "Biasi", "Riva Compact HE", "M96.28SM/C", "", "2004", "2008", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "27.9", "27.9", "", "", "86.1", "77.5", "", "54.5", "", "2", "1", "", "104", "1", "2", "160", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.7", "92.0", "", "", "", "", "91.4"]} +{"pcdb_id": 10049, "brand_name": "Biasi", "model_name": "Riva Compact HE", "model_qualifier": "M96.28SM/C", "winter_efficiency_pct": 85.1, "summer_efficiency_pct": 76.5, "comparative_hot_water_efficiency_pct": 53.8, "output_kw_max": 27.9, "final_year_of_manufacture": 2008, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010049", "000208", "0", "2008/May/22 11:31", "Biasi (UK)", "Biasi", "Riva Compact HE", "M96.28SM/C", "47-970-24", "2004", "2008", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "27.9", "27.9", "", "", "85.1", "76.5", "", "53.8", "", "2", "", "", "104", "1", "2", "160", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "86.8", "90.0", "", "", "", "", "89.4"]} +{"pcdb_id": 10050, "brand_name": "Biasi", "model_name": "Riva Compact HE", "model_qualifier": "M96.28SR/C", "winter_efficiency_pct": 86.1, "summer_efficiency_pct": 77.1, "comparative_hot_water_efficiency_pct": 56.3, "output_kw_max": 27.9, "final_year_of_manufacture": 2008, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010050", "000208", "0", "2012/Mar/27 10:12", "Biasi (UK)", "Biasi", "Riva Compact HE", "M96.28SR/C", "", "2004", "2008", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "27.9", "27.9", "", "", "86.1", "77.1", "", "56.3", "", "2", "1", "", "102", "1", "2", "160", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.7", "92.0", "", "", "", "", "91.4"]} +{"pcdb_id": 10051, "brand_name": "Biasi", "model_name": "Riva Compact HE", "model_qualifier": "M96.28SR/C", "winter_efficiency_pct": 85.1, "summer_efficiency_pct": 76.1, "comparative_hot_water_efficiency_pct": 55.6, "output_kw_max": 27.9, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010051", "000208", "0", "2012/Mar/27 10:12", "Biasi (UK)", "Biasi", "Riva Compact HE", "M96.28SR/C", "41-970-12", "2004", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "27.9", "27.9", "", "", "85.1", "76.1", "", "55.6", "", "2", "", "", "102", "1", "2", "160", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "86.8", "90.0", "", "", "", "", "89.4"]} +{"pcdb_id": 10052, "brand_name": "Biasi", "model_name": "Garda HE", "model_qualifier": "M96.28SM/B", "winter_efficiency_pct": 86.1, "summer_efficiency_pct": 77.5, "comparative_hot_water_efficiency_pct": 54.5, "output_kw_max": 27.1, "final_year_of_manufacture": 2008, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010052", "000208", "0", "2008/May/22 11:25", "Biasi (UK)", "Biasi", "Garda HE", "M96.28SM/B", "", "2004", "2008", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "27.10", "27.10", "", "", "86.1", "77.5", "", "54.5", "", "2", "1", "", "104", "1", "2", "160", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.7", "92.0", "", "", "", "", "91.4"]} +{"pcdb_id": 10053, "brand_name": "Biasi", "model_name": "Garda HE", "model_qualifier": "M96.28SM/B", "winter_efficiency_pct": 85.1, "summer_efficiency_pct": 76.5, "comparative_hot_water_efficiency_pct": 53.8, "output_kw_max": 27.1, "final_year_of_manufacture": 2008, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010053", "000208", "0", "2008/May/22 11:26", "Biasi (UK)", "Biasi", "Garda HE", "M96.28SM/B", "47-970-26", "2004", "2008", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "27.10", "27.10", "", "", "85.1", "76.5", "", "53.8", "", "2", "", "", "104", "1", "2", "160", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "86.8", "90.0", "", "", "", "", "89.4"]} +{"pcdb_id": 10054, "brand_name": "Biasi", "model_name": "Garda HE", "model_qualifier": "M96.24SM/B", "winter_efficiency_pct": 86.2, "summer_efficiency_pct": 77.6, "comparative_hot_water_efficiency_pct": 54.5, "output_kw_max": 24.1, "final_year_of_manufacture": 2008, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010054", "000208", "0", "2008/May/22 11:23", "Biasi (UK)", "Biasi", "Garda HE", "M96.24SM/B", "", "2004", "2008", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24.10", "24.10", "", "", "86.2", "77.6", "", "54.5", "", "2", "1", "", "104", "1", "2", "140", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.8", "92.2", "", "", "", "", "91.5"]} +{"pcdb_id": 10055, "brand_name": "Biasi", "model_name": "Garda HE", "model_qualifier": "M96.24SM/B", "winter_efficiency_pct": 85.2, "summer_efficiency_pct": 76.6, "comparative_hot_water_efficiency_pct": 53.9, "output_kw_max": 24.1, "final_year_of_manufacture": 2008, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010055", "000208", "0", "2008/May/22 11:23", "Biasi (UK)", "Biasi", "Garda HE", "M96.24SM/B", "47-970-25", "2004", "2008", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.10", "24.10", "", "", "85.2", "76.6", "", "53.9", "", "2", "", "", "104", "1", "2", "140", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "86.9", "90.2", "", "", "", "", "89.6"]} +{"pcdb_id": 10056, "brand_name": "Biasi", "model_name": "Garda HE Silver", "model_qualifier": "M96.24SM/D", "winter_efficiency_pct": 86.2, "summer_efficiency_pct": 77.6, "comparative_hot_water_efficiency_pct": 54.5, "output_kw_max": 24.1, "final_year_of_manufacture": 2008, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010056", "000208", "0", "2008/May/22 11:22", "Biasi (UK)", "Biasi", "Garda HE Silver", "M96.24SM/D", "", "2004", "2008", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24.10", "24.10", "", "", "86.2", "77.6", "", "54.5", "", "2", "1", "", "104", "1", "2", "140", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.8", "92.2", "", "", "", "", "91.5"]} +{"pcdb_id": 10057, "brand_name": "Biasi", "model_name": "Garda HE Silver", "model_qualifier": "M96.24SM/D", "winter_efficiency_pct": 85.2, "summer_efficiency_pct": 76.6, "comparative_hot_water_efficiency_pct": 53.9, "output_kw_max": 24.1, "final_year_of_manufacture": 2008, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010057", "000208", "0", "2008/May/22 11:22", "Biasi (UK)", "Biasi", "Garda HE Silver", "M96.24SM/D", "47-970-27", "2004", "2008", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.10", "24.10", "", "", "85.2", "76.6", "", "53.9", "", "2", "", "", "104", "1", "2", "140", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "86.9", "90.2", "", "", "", "", "89.6"]} +{"pcdb_id": 10058, "brand_name": "Biasi", "model_name": "Garda HE Silver", "model_qualifier": "M96.28SM/D", "winter_efficiency_pct": 86.1, "summer_efficiency_pct": 77.5, "comparative_hot_water_efficiency_pct": 54.5, "output_kw_max": 27.9, "final_year_of_manufacture": 2008, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010058", "000208", "0", "2008/May/22 11:28", "Biasi (UK)", "Biasi", "Garda HE Silver", "M96.28SM/D", "", "2004", "2008", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "27.90", "27.90", "", "", "86.1", "77.5", "", "54.5", "", "2", "1", "", "104", "1", "2", "160", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.7", "92.0", "", "", "", "", "91.4"]} +{"pcdb_id": 10059, "brand_name": "Biasi", "model_name": "Garda HE Silver", "model_qualifier": "M96.28SM/D", "winter_efficiency_pct": 85.1, "summer_efficiency_pct": 76.5, "comparative_hot_water_efficiency_pct": 53.8, "output_kw_max": 27.9, "final_year_of_manufacture": 2008, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010059", "000208", "0", "2008/May/22 11:29", "Biasi (UK)", "Biasi", "Garda HE Silver", "M96.28SM/D", "47-970-28", "2004", "2008", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "27.90", "27.90", "", "", "85.1", "76.5", "", "53.8", "", "2", "", "", "104", "1", "2", "160", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "86.8", "90.0", "", "", "", "", "89.4"]} +{"pcdb_id": 10060, "brand_name": "Boulter", "model_name": "Buderus", "model_qualifier": "600/11R", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 11.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010060", "000041", "0", "2012/Mar/27 10:12", "Boulter Buderus", "Boulter", "Buderus", "600/11R", "", "2000", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "11.0", "11.0", "", "", "88.6", "79.6", "", "58.2", "", "2", "", "", "102", "1", "2", "115", "6.5", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.1", "98.3", "", "", "", "", "96.4"]} +{"pcdb_id": 10061, "brand_name": "Boulter", "model_name": "Buderus", "model_qualifier": "600/19R", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 19.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010061", "000041", "0", "2012/Mar/27 10:12", "Boulter Buderus", "Boulter", "Buderus", "600/19R", "", "2000", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "19.0", "19.0", "", "", "88.6", "79.6", "", "58.1", "", "2", "", "", "102", "1", "2", "115", "6.5", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.1", "98.2", "", "", "", "", "96.3"]} +{"pcdb_id": 10062, "brand_name": "Boulter", "model_name": "Buderus", "model_qualifier": "600/24R", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 24.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010062", "000041", "0", "2012/Mar/27 10:12", "Boulter Buderus", "Boulter", "Buderus", "600/24R", "", "2000", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24.0", "24.0", "", "", "88.5", "79.5", "", "58.1", "", "2", "", "", "102", "1", "2", "115", "6.5", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "98.0", "", "", "", "", "96.1"]} +{"pcdb_id": 10063, "brand_name": "Fagor Electrodomesticos S.Coop", "model_name": "Morco FEB-24E Supercompact", "model_qualifier": "FEB-24EUK", "winter_efficiency_pct": 83.0, "summer_efficiency_pct": 72.9, "comparative_hot_water_efficiency_pct": 51.3, "output_kw_max": 23.7, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010063", "000219", "0", "2013/Jun/25 14:31", "Fagor Electrodomesticos S.Coop", "Fagor Electrodomesticos S.Coop", "Morco FEB-24E Supercompact", "FEB-24EUK", "912110968", "2004", "current", "2", "2", "1", "2", "0", "", "", "1", "2", "2", "23.7", "23.7", "", "", "83.0", "72.9", "", "51.3", "", "2", "0", "", "104", "1", "2", "30", "4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "84.6", "87.0", "", "", "", "", "86.6"]} +{"pcdb_id": 10064, "brand_name": "Fagor Electrodomesticos S.Coop", "model_name": "Morco FEB-24E Supercompact", "model_qualifier": "FEB-24EUK Nat", "winter_efficiency_pct": 80.9, "summer_efficiency_pct": 70.8, "comparative_hot_water_efficiency_pct": 49.8, "output_kw_max": 23.7, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010064", "000219", "0", "2013/Jun/25 14:31", "Fagor Electrodomesticos S.Coop", "Fagor Electrodomesticos S.Coop", "Morco FEB-24E Supercompact", "FEB-24EUK Nat", "912110959", "2004", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "23.7", "23.7", "", "", "80.9", "70.8", "", "49.8", "", "2", "", "", "104", "1", "2", "30", "4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.1", "82.2", "", "", "", "", "82.2"]} +{"pcdb_id": 10065, "brand_name": "Fagor Electrodomesticos S.Coop", "model_name": "FEB-24E Supercompact", "model_qualifier": "FEB-24EUK N", "winter_efficiency_pct": 80.9, "summer_efficiency_pct": 70.8, "comparative_hot_water_efficiency_pct": 49.8, "output_kw_max": 23.7, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010065", "000219", "0", "2013/Jun/25 14:31", "Fagor Electrodomesticos S.Coop", "Fagor Electrodomesticos S.Coop", "FEB-24E Supercompact", "FEB-24EUK N", "912110940", "2004", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "23.7", "23.7", "", "", "80.9", "70.8", "", "49.8", "", "2", "", "", "104", "1", "2", "30", "4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.1", "82.2", "", "", "", "", "82.2"]} +{"pcdb_id": 10066, "brand_name": "Fagor Electrodomesticos S.Coop", "model_name": "FEB-24E Supercompact", "model_qualifier": "FEB-24EUK", "winter_efficiency_pct": 83.0, "summer_efficiency_pct": 72.9, "comparative_hot_water_efficiency_pct": 51.3, "output_kw_max": 23.7, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010066", "000219", "0", "2013/Jun/25 14:31", "Fagor Electrodomesticos S.Coop", "Fagor Electrodomesticos S.Coop", "FEB-24E Supercompact", "FEB-24EUK", "912111002", "2004", "current", "2", "2", "1", "2", "0", "", "", "1", "2", "2", "23.7", "23.7", "", "", "83.0", "72.9", "", "51.3", "", "2", "0", "", "104", "1", "2", "30", "4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "84.6", "87.0", "", "", "", "", "86.6"]} +{"pcdb_id": 10067, "brand_name": "Fagor Electrodomesticos S.Coop", "model_name": "FEB-27E Supercompact", "model_qualifier": "FEB-27EUK N", "winter_efficiency_pct": 79.3, "summer_efficiency_pct": 69.2, "comparative_hot_water_efficiency_pct": 48.7, "output_kw_max": 27.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010067", "000219", "0", "2013/Jun/25 14:32", "Fagor Electrodomesticos S.Coop", "Fagor Electrodomesticos S.Coop", "FEB-27E Supercompact", "FEB-27EUK N", "912110986", "2004", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "27", "27", "", "", "79.3", "69.2", "", "48.7", "", "2", "", "", "104", "1", "2", "30", "4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.5", "79.6", "", "", "", "", "79.9"]} +{"pcdb_id": 10068, "brand_name": "Ideal", "model_name": "isar", "model_qualifier": "HE30", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 55.9, "output_kw_max": 25.1, "final_year_of_manufacture": 2011, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010068", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "isar", "HE30", "47-348-30", "2003", "2011", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "25.1", "25.1", "", "", "88.1", "79.5", "", "55.9", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "97.1", "", "", "", "", "95.4"]} +{"pcdb_id": 10069, "brand_name": "Evo", "model_name": "HE C22/30", "model_qualifier": "HE C22/30", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 55.9, "output_kw_max": 23.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010069", "000008", "0", "2006/Jan/17 12:31", "Ideal Boilers", "Evo", "HE C22/30", "HE C22/30", "GC4734833", "2003", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "23.3", "23.3", "", "", "88.1", "79.5", "", "55.9", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "97.1", "", "", "", "", "95.4"]} +{"pcdb_id": 10070, "brand_name": "Evo", "model_name": "HE 12", "model_qualifier": "HE 12", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 12.7, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010070", "000008", "0", "2012/Mar/27 10:12", "Ideal Boilers", "Evo", "HE 12", "HE 12", "GC4139796", "2004", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "12.7", "12.7", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "40", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.2", "96.8", "", "", "", "", "95.1"]} +{"pcdb_id": 10071, "brand_name": "Ideal", "model_name": "Icos", "model_qualifier": "HE 12", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 12.7, "final_year_of_manufacture": 2011, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010071", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "Icos", "HE 12", "GC4139795", "2004", "2011", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "12.7", "12.7", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "40", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.2", "96.8", "", "", "", "", "95.1"]} +{"pcdb_id": 10072, "brand_name": "Ariston", "model_name": "Intesa TP 23 MFFI", "model_qualifier": "", "winter_efficiency_pct": 81.1, "summer_efficiency_pct": 71.0, "comparative_hot_water_efficiency_pct": 49.9, "output_kw_max": 24.8, "final_year_of_manufacture": 2007, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010072", "000080", "0", "2007/Jun/18 09:23", "Merloni TermoSanitari SpA", "Ariston", "Intesa TP 23 MFFI", "", "GC No 47-116-32", "2004", "2007", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "24.8", "24.8", "", "", "81.1", "71.0", "", "49.9", "", "2", "", "", "104", "1", "2", "110", "7", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "84.4", "81.7", "", "", "", "", "82.2"]} +{"pcdb_id": 10073, "brand_name": "Ariston", "model_name": "Intesa TP 30 MFFI", "model_qualifier": "", "winter_efficiency_pct": 80.8, "summer_efficiency_pct": 70.7, "comparative_hot_water_efficiency_pct": 49.7, "output_kw_max": 36.6, "final_year_of_manufacture": 2007, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010073", "000080", "0", "2007/Jun/18 09:23", "Merloni TermoSanitari SpA", "Ariston", "Intesa TP 30 MFFI", "", "GC No 47-116-33", "2004", "2007", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "36.6", "36.6", "", "", "80.8", "70.7", "", "49.7", "", "2", "", "", "104", "1", "2", "148", "7", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "83.6", "81.1", "", "", "", "", "81.6"]} +{"pcdb_id": 10074, "brand_name": "Ariston", "model_name": "Excalibur 23 MFFI", "model_qualifier": "Excalibur 80 MFFI", "winter_efficiency_pct": 81.0, "summer_efficiency_pct": 70.9, "comparative_hot_water_efficiency_pct": 49.9, "output_kw_max": 23.7, "final_year_of_manufacture": 2007, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010074", "000080", "0", "2007/Jun/18 09:24", "Merloni TermoSanitari SpA", "Ariston", "Excalibur 23 MFFI", "Excalibur 80 MFFI", "GC No 47-116-30", "2004", "2007", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "23.7", "23.7", "", "", "81.0", "70.9", "", "49.9", "", "2", "", "", "104", "1", "2", "135", "7", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "83.3", "81.5", "", "", "", "", "81.9"]} +{"pcdb_id": 10075, "brand_name": "Ariston", "model_name": "Excalibur 27 MFFI", "model_qualifier": "Excalibur 100 MFFI", "winter_efficiency_pct": 80.3, "summer_efficiency_pct": 70.2, "comparative_hot_water_efficiency_pct": 49.3, "output_kw_max": 26.9, "final_year_of_manufacture": 2007, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010075", "000080", "0", "2007/Jun/18 09:26", "Merloni TermoSanitari SpA", "Ariston", "Excalibur 27 MFFI", "Excalibur 100 MFFI", "GC No 47-116-31", "2004", "2007", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "26.9", "26.9", "", "", "80.3", "70.2", "", "49.3", "", "2", "", "", "104", "1", "2", "155", "7", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "", "", "0004", "", "", "", "", "", "", "", "", "82.9", "80.0", "", "", "", "", "80.6"]} +{"pcdb_id": 10076, "brand_name": "Hepworth Heating", "model_name": "EnviroPlus F24e", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 56.2, "output_kw_max": 25.1, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010076", "000206", "0", "2009/Mar/31 14:32", "Hepworth Heating", "Hepworth Heating", "EnviroPlus F24e", "", "GC 47-920-45", "2004", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "25.1", "25.1", "", "", "88.5", "79.9", "", "56.2", "", "2", "", "", "104", "1", "2", "180", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "98.0", "", "", "", "", "96.2"]} +{"pcdb_id": 10077, "brand_name": "Gledhill", "model_name": "GulfStream A-Class", "model_qualifier": "12/SS", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 81.9, "comparative_hot_water_efficiency_pct": 48.9, "output_kw_max": 11.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 1, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010077", "000072", "0", "2024/Jan/31 10:17", "Gledhill Water Storage", "Gledhill", "GulfStream A-Class", "12/SS", "", "2004", "current", "1", "1", "1", "2", "0", "", "", "2", "2", "2", "11.6", "11.6", "", "", "89.2", "81.9", "", "48.9", "", "2", "", "", "106", "1", "2", "", "", "1", "1", "0", "95", "0", "55", "2", "75", "60", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.2", "100.3", "", "", "", "", "97.8"]} +{"pcdb_id": 10078, "brand_name": "Gledhill", "model_name": "GulfStream A-Class", "model_qualifier": "12/OV", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 81.9, "comparative_hot_water_efficiency_pct": 48.9, "output_kw_max": 11.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 1, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010078", "000072", "0", "2024/Jan/31 10:17", "Gledhill Water Storage", "Gledhill", "GulfStream A-Class", "12/OV", "", "2004", "current", "1", "1", "1", "2", "0", "", "", "2", "2", "2", "11.6", "11.6", "", "", "89.2", "81.9", "", "48.9", "", "2", "", "", "106", "1", "2", "", "", "1", "1", "0", "95", "0", "55", "2", "75", "60", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.2", "100.3", "", "", "", "", "97.8"]} +{"pcdb_id": 10079, "brand_name": "Gledhill", "model_name": "GulfStream A-Class", "model_qualifier": "20/SS", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 81.7, "comparative_hot_water_efficiency_pct": 48.8, "output_kw_max": 19.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 1, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010079", "000072", "0", "2024/Jan/31 10:17", "Gledhill Water Storage", "Gledhill", "GulfStream A-Class", "20/SS", "", "2004", "current", "1", "1", "1", "2", "0", "", "", "2", "2", "2", "19.3", "19.3", "", "", "89.0", "81.7", "", "48.8", "", "2", "", "", "106", "1", "2", "", "", "1", "1", "0", "95", "0", "55", "2", "75", "60", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "86.9", "99.7", "", "", "", "", "97.2"]} +{"pcdb_id": 10080, "brand_name": "Gledhill", "model_name": "GulfStream A-Class", "model_qualifier": "20/OV", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 81.7, "comparative_hot_water_efficiency_pct": 48.8, "output_kw_max": 19.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 1, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010080", "000072", "0", "2024/Jan/31 10:17", "Gledhill Water Storage", "Gledhill", "GulfStream A-Class", "20/OV", "", "2004", "current", "1", "1", "1", "2", "0", "", "", "2", "2", "2", "19.3", "19.3", "", "", "89.0", "81.7", "", "48.8", "", "2", "", "", "106", "1", "2", "", "", "1", "1", "0", "95", "0", "55", "2", "75", "60", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "86.9", "99.7", "", "", "", "", "97.2"]} +{"pcdb_id": 10081, "brand_name": "Gledhill", "model_name": "GulfStream A-Class", "model_qualifier": "30/SS", "winter_efficiency_pct": 87.6, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 48.0, "output_kw_max": 28.8, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 1, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010081", "000072", "0", "2024/Jan/31 10:17", "Gledhill Water Storage", "Gledhill", "GulfStream A-Class", "30/SS", "", "2004", "current", "1", "1", "1", "2", "0", "", "", "2", "2", "2", "28.8", "28.8", "", "", "87.6", "80.3", "", "48.0", "", "2", "", "", "106", "1", "2", "", "", "1", "1", "0", "95", "0", "55", "2", "75", "60", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "86.6", "96.4", "", "", "", "", "94.5"]} +{"pcdb_id": 10082, "brand_name": "Gledhill", "model_name": "GulfStream A-Class", "model_qualifier": "30/OV", "winter_efficiency_pct": 87.6, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 48.0, "output_kw_max": 28.8, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 1, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010082", "000072", "0", "2024/Jan/31 10:17", "Gledhill Water Storage", "Gledhill", "GulfStream A-Class", "30/OV", "", "2004", "current", "1", "1", "1", "2", "0", "", "", "2", "2", "2", "28.8", "28.8", "", "", "87.6", "80.3", "", "48.0", "", "2", "", "", "106", "1", "2", "", "", "1", "1", "0", "95", "0", "55", "2", "75", "60", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "86.6", "96.4", "", "", "", "", "94.5"]} +{"pcdb_id": 10083, "brand_name": "Boulter", "model_name": "Buderus", "model_qualifier": "600-24RP", "winter_efficiency_pct": 89.5, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 58.8, "output_kw_max": 24.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010083", "000041", "0", "2012/Mar/27 10:12", "Boulter Buderus", "Boulter", "Buderus", "600-24RP", "", "2000", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "24.0", "24.0", "", "", "89.5", "80.5", "", "58.8", "", "2", "1", "", "102", "1", "2", "115", "6.5", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.9", "100.2", "", "", "", "", "98.2"]} +{"pcdb_id": 10084, "brand_name": "Boulter", "model_name": "Buderus", "model_qualifier": "600-24SP", "winter_efficiency_pct": 89.5, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 58.8, "output_kw_max": 22.0, "final_year_of_manufacture": 2007, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010084", "000041", "0", "2012/Mar/27 10:12", "Boulter Buderus", "Boulter", "Buderus", "600-24SP", "7105050", "2000", "2007", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "22", "22", "", "", "89.5", "80.5", "", "58.8", "", "2", "1", "", "102", "1", "2", "115", "6.5", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.9", "100.2", "", "", "", "", "98.2"]} +{"pcdb_id": 10085, "brand_name": "Boulter", "model_name": "Buderus", "model_qualifier": "600-24CP", "winter_efficiency_pct": 89.5, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 58.8, "output_kw_max": 22.0, "final_year_of_manufacture": 2007, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010085", "000041", "0", "2012/Mar/27 10:12", "Boulter Buderus", "Boulter", "Buderus", "600-24CP", "7105060", "2000", "2007", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "22.0", "22.0", "", "", "89.5", "80.5", "", "58.8", "", "2", "1", "", "102", "1", "2", "115", "6.5", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.9", "100.2", "", "", "", "", "98.2"]} +{"pcdb_id": 10086, "brand_name": "Boulter", "model_name": "Buderus", "model_qualifier": "600-19RP", "winter_efficiency_pct": 89.6, "summer_efficiency_pct": 80.6, "comparative_hot_water_efficiency_pct": 58.9, "output_kw_max": 19.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010086", "000041", "0", "2012/Mar/27 10:12", "Boulter Buderus", "Boulter", "Buderus", "600-19RP", "", "2000", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "19", "19", "", "", "89.6", "80.6", "", "58.9", "", "2", "1", "", "102", "1", "2", "115", "6.5", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.1", "100.4", "", "", "", "", "98.4"]} +{"pcdb_id": 10087, "brand_name": "Boulter", "model_name": "Buderus", "model_qualifier": "600-19SP", "winter_efficiency_pct": 89.6, "summer_efficiency_pct": 80.6, "comparative_hot_water_efficiency_pct": 58.9, "output_kw_max": 17.4, "final_year_of_manufacture": 2007, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010087", "000041", "0", "2012/Mar/27 10:12", "Boulter Buderus", "Boulter", "Buderus", "600-19SP", "7105040", "2000", "2007", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "17.4", "17.4", "", "", "89.6", "80.6", "", "58.9", "", "2", "1", "", "102", "1", "2", "115", "6.5", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.1", "100.4", "", "", "", "", "98.4"]} +{"pcdb_id": 10088, "brand_name": "Boulter", "model_name": "Buderus", "model_qualifier": "600-11RP", "winter_efficiency_pct": 89.6, "summer_efficiency_pct": 80.6, "comparative_hot_water_efficiency_pct": 58.9, "output_kw_max": 10.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010088", "000041", "0", "2012/Mar/27 10:12", "Boulter Buderus", "Boulter", "Buderus", "600-11RP", "", "2000", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "10.5", "10.5", "", "", "89.6", "80.6", "", "58.9", "", "2", "1", "", "102", "1", "2", "115", "6.5", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.1", "100.5", "", "", "", "", "98.5"]} +{"pcdb_id": 10089, "brand_name": "Boulter", "model_name": "Buderus", "model_qualifier": "600-11SP", "winter_efficiency_pct": 90.1, "summer_efficiency_pct": 81.1, "comparative_hot_water_efficiency_pct": 59.3, "output_kw_max": 10.5, "final_year_of_manufacture": 2007, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010089", "000041", "0", "2012/Mar/27 10:12", "Boulter Buderus", "Boulter", "Buderus", "600-11SP", "7105030", "2000", "2007", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "10.5", "10.5", "", "", "90.1", "81.1", "", "59.3", "", "2", "1", "", "102", "1", "2", "115", "6.5", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.3", "101.7", "", "", "", "", "99.5"]} +{"pcdb_id": 10090, "brand_name": "Boulter", "model_name": "Buderus", "model_qualifier": "800-43P", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 42.9, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010090", "000041", "0", "2012/Mar/27 10:12", "Boulter Buderus", "Boulter", "Buderus", "800-43P", "", "1999", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "42.9", "42.9", "", "", "88.9", "79.9", "", "58.3", "", "2", "1", "", "102", "1", "2", "180", "8", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.1", "98.5", "", "", "", "", "96.9"]} +{"pcdb_id": 10091, "brand_name": "Boulter", "model_name": "Buderus", "model_qualifier": "800-29P", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 29.9, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010091", "000041", "0", "2012/Mar/27 10:12", "Boulter Buderus", "Boulter", "Buderus", "800-29P", "", "1999", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "29.9", "29.9", "", "", "88.9", "79.9", "", "58.3", "", "2", "1", "", "102", "1", "2", "130", "8", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.8", "98.6", "", "", "", "", "97.0"]} +{"pcdb_id": 10092, "brand_name": "Boulter", "model_name": "Buderus", "model_qualifier": "800-24P", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 23.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010092", "000041", "0", "2012/Mar/27 10:12", "Boulter Buderus", "Boulter", "Buderus", "800-24P", "", "1999", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "23.4", "23.4", "", "", "88.8", "79.8", "", "58.3", "", "2", "1", "", "102", "1", "2", "120", "8", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.6", "98.5", "", "", "", "", "96.8"]} +{"pcdb_id": 10093, "brand_name": "Alpha", "model_name": "CD50", "model_qualifier": "", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 49.6, "output_kw_max": 32.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010093", "000001", "0", "2024/Jan/31 10:17", "Alpha Therm", "Alpha", "CD50", "", "", "2004", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "32", "32", "", "", "88.2", "81.0", "", "49.6", "", "2", "", "", "106", "1", "2", "140", "2", "2", "2", "0", "52", "0", "25", "5", "60", "0.97", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.1", "96.8", "", "", "", "", "95.3"]} +{"pcdb_id": 10095, "brand_name": "Boulter", "model_name": "Buderus", "model_qualifier": "500-28C", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.4, "comparative_hot_water_efficiency_pct": 56.5, "output_kw_max": 23.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010095", "000041", "0", "2006/Jan/17 12:31", "Boulter Buderus", "Boulter", "Buderus", "500-28C", "87470220", "2004", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "23.0", "23.0", "", "", "89.0", "80.4", "", "56.5", "", "2", "", "", "104", "1", "2", "110", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "99.4", "", "", "", "", "97.2"]} +{"pcdb_id": 10096, "brand_name": "Boulter", "model_name": "Buderus", "model_qualifier": "500-28CP", "winter_efficiency_pct": 90.0, "summer_efficiency_pct": 81.4, "comparative_hot_water_efficiency_pct": 57.3, "output_kw_max": 23.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010096", "000041", "0", "2006/Jan/17 12:31", "Boulter Buderus", "Boulter", "Buderus", "500-28CP", "", "2004", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "23.0", "23.0", "", "", "90.0", "81.4", "", "57.3", "", "2", "1", "", "104", "1", "2", "10", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.8", "101.6", "", "", "", "", "99.3"]} +{"pcdb_id": 10097, "brand_name": "Boulter", "model_name": "Buderus", "model_qualifier": "500 - 24S", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 23.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010097", "000041", "0", "2012/Mar/27 10:12", "Boulter Buderus", "Boulter", "Buderus", "500 - 24S", "87470222", "2004", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "23", "23", "", "", "89.0", "80.0", "", "58.4", "", "2", "", "", "102", "1", "2", "110", "3", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "99.4", "", "", "", "", "97.2"]} +{"pcdb_id": 10098, "brand_name": "Boulter", "model_name": "Buderus", "model_qualifier": "500-24SP", "winter_efficiency_pct": 90.0, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 59.2, "output_kw_max": 23.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010098", "000041", "0", "2012/Mar/27 10:12", "Boulter Buderus", "Boulter", "Buderus", "500-24SP", "", "2004", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "23", "23", "", "", "90.0", "81.0", "", "59.2", "", "2", "1", "", "102", "1", "2", "110", "3", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.8", "101.6", "", "", "", "", "99.3"]} +{"pcdb_id": 10099, "brand_name": "Sime", "model_name": "Format 30 HE LPG", "model_qualifier": "", "winter_efficiency_pct": 90.1, "summer_efficiency_pct": 81.5, "comparative_hot_water_efficiency_pct": 57.3, "output_kw_max": 27.3, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010099", "000213", "0", "2018/Feb/26 17:04", "Fonderie Sime S.p.A.", "Sime", "Format 30 HE LPG", "", "", "2004", "2018", "2", "2", "1", "2", "0", "", "", "2", "3", "2", "27.3", "27.3", "", "", "90.1", "81.5", "", "57.3", "", "2", "1", "", "104", "1", "2", "50", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.2", "101.7", "", "", "", "", "99.5"]} +{"pcdb_id": 10100, "brand_name": "Sime", "model_name": "Format 30 HE", "model_qualifier": "", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 56.6, "output_kw_max": 27.3, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010100", "000213", "0", "2018/Feb/26 17:04", "Fonderie Sime S.p.A.", "Sime", "Format 30 HE", "", "", "2004", "2018", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "27.3", "27.3", "", "", "89.1", "80.5", "", "56.6", "", "2", "", "", "104", "1", "2", "50", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.2", "99.5", "", "", "", "", "97.3"]} +{"pcdb_id": 10101, "brand_name": "Sime", "model_name": "Format System 25 HE LPG", "model_qualifier": "", "winter_efficiency_pct": 89.6, "summer_efficiency_pct": 80.6, "comparative_hot_water_efficiency_pct": 58.9, "output_kw_max": 22.7, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010101", "000213", "0", "2018/Feb/28 17:01", "Fonderie Sime S.p.A.", "Sime", "Format System 25 HE LPG", "", "", "2004", "2018", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "22.7", "22.7", "", "", "89.6", "80.6", "", "58.9", "", "2", "1", "", "102", "1", "2", "50", "10", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.8", "100.6", "", "", "", "", "98.5"]} +{"pcdb_id": 10102, "brand_name": "Sime", "model_name": "Format System 25 HE", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 22.7, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010102", "000213", "0", "2018/Feb/28 17:00", "Fonderie Sime S.p.A.", "Sime", "Format System 25 HE", "", "", "2004", "2018", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "22.7", "22.7", "", "", "88.6", "79.6", "", "58.1", "", "2", "", "", "102", "1", "2", "50", "10", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "98.4", "", "", "", "", "96.4"]} +{"pcdb_id": 10103, "brand_name": "Sime", "model_name": "Format 25 HE LPG", "model_qualifier": "", "winter_efficiency_pct": 89.6, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 57.0, "output_kw_max": 22.7, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010103", "000213", "0", "2018/Feb/26 17:03", "Fonderie Sime S.p.A.", "Sime", "Format 25 HE LPG", "", "", "2004", "2018", "2", "2", "1", "2", "0", "", "", "2", "3", "2", "22.7", "22.7", "", "", "89.6", "81.0", "", "57.0", "", "2", "1", "", "104", "1", "2", "50", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.8", "100.6", "", "", "", "", "98.5"]} +{"pcdb_id": 10104, "brand_name": "Sime", "model_name": "Format 25 HE", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 56.3, "output_kw_max": 22.7, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010104", "000213", "0", "2018/Feb/26 17:03", "Fonderie Sime S.p.A.", "Sime", "Format 25 HE", "", "", "2004", "2018", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "22.7", "22.7", "", "", "88.6", "80.0", "", "56.3", "", "2", "", "", "104", "1", "2", "50", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "98.4", "", "", "", "", "96.4"]} +{"pcdb_id": 10105, "brand_name": "Sime", "model_name": "Format System 30 HE LPG", "model_qualifier": "", "winter_efficiency_pct": 90.1, "summer_efficiency_pct": 81.1, "comparative_hot_water_efficiency_pct": 59.2, "output_kw_max": 27.3, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010105", "000213", "0", "2018/Mar/05 14:05", "Fonderie Sime S.p.A.", "Sime", "Format System 30 HE LPG", "", "", "2004", "2018", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "27.3", "27.3", "", "", "90.1", "81.1", "", "59.2", "", "2", "1", "", "102", "1", "2", "50", "10", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.2", "101.7", "", "", "", "", "99.5"]} +{"pcdb_id": 10106, "brand_name": "Sime", "model_name": "Format System 30 HE", "model_qualifier": "", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 27.3, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010106", "000213", "0", "2018/Mar/05 14:04", "Fonderie Sime S.p.A.", "Sime", "Format System 30 HE", "", "", "2004", "2018", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "27.3", "27.3", "", "", "89.1", "80.1", "", "58.5", "", "2", "", "", "102", "1", "2", "50", "10", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.2", "99.5", "", "", "", "", "97.3"]} +{"pcdb_id": 10107, "brand_name": "Baxi", "model_name": "Combi", "model_qualifier": "Instant 105 HE", "winter_efficiency_pct": 87.8, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 55.7, "output_kw_max": 29.6, "final_year_of_manufacture": 2008, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010107", "000005", "0", "2010/Nov/19 09:02", "Baxi Potterton", "Baxi", "Combi", "Instant 105 HE", "", "2004", "2008", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "29.6", "29.6", "", "", "87.8", "79.2", "", "55.7", "", "2", "0", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "0", "", "0005", "", "", "", "", "", "", "", "", "89.5", "93.4", "", "", "", "", "92.7"]} +{"pcdb_id": 10108, "brand_name": "Baxi", "model_name": "Combi", "model_qualifier": "Instant 105 HE", "winter_efficiency_pct": 85.8, "summer_efficiency_pct": 77.2, "comparative_hot_water_efficiency_pct": 54.3, "output_kw_max": 29.6, "final_year_of_manufacture": 2008, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010108", "000005", "0", "2010/Nov/19 09:02", "Baxi Potterton", "Baxi", "Combi", "Instant 105 HE", "GC No. 47-075-19", "2004", "2008", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "29.6", "29.6", "", "", "85.8", "77.2", "", "54.3", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "0", "", "0005", "", "", "", "", "", "", "", "", "87.6", "91.3", "", "", "", "", "90.6"]} +{"pcdb_id": 10109, "brand_name": "Baxi", "model_name": "Combi", "model_qualifier": "Instant 80 HE", "winter_efficiency_pct": 87.8, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 55.7, "output_kw_max": 24.0, "final_year_of_manufacture": 2008, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010109", "000005", "0", "2010/Nov/19 09:02", "Baxi Potterton", "Baxi", "Combi", "Instant 80 HE", "", "2004", "2008", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24.0", "24.0", "", "", "87.8", "79.2", "", "55.7", "", "2", "0", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "0", "", "0005", "", "", "", "", "", "", "", "", "89.2", "93.7", "", "", "", "", "92.8"]} +{"pcdb_id": 10110, "brand_name": "Baxi", "model_name": "Combi", "model_qualifier": "Instant 80 HE", "winter_efficiency_pct": 85.8, "summer_efficiency_pct": 77.2, "comparative_hot_water_efficiency_pct": 54.3, "output_kw_max": 24.0, "final_year_of_manufacture": 2008, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010110", "000005", "0", "2010/Nov/19 09:01", "Baxi Potterton", "Baxi", "Combi", "Instant 80 HE", "GC No. 47-075-17", "2004", "2008", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.0", "24.0", "", "", "85.8", "77.2", "", "54.3", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "0", "", "0005", "", "", "", "", "", "", "", "", "87.2", "91.5", "", "", "", "", "90.7"]} +{"pcdb_id": 10111, "brand_name": "Baxi", "model_name": "Combi", "model_qualifier": "105 HE", "winter_efficiency_pct": 87.8, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 55.7, "output_kw_max": 29.6, "final_year_of_manufacture": 2011, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010111", "000005", "0", "2013/May/07 10:25", "Baxi Potterton", "Baxi", "Combi", "105 HE", "", "2004", "2011", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "29.6", "29.6", "", "", "87.8", "79.2", "", "55.7", "", "2", "0", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "", "", "0005", "", "", "", "", "", "", "", "", "89.5", "93.4", "", "", "", "", "92.7"]} +{"pcdb_id": 10112, "brand_name": "Baxi", "model_name": "Combi", "model_qualifier": "105 HE", "winter_efficiency_pct": 85.8, "summer_efficiency_pct": 77.2, "comparative_hot_water_efficiency_pct": 54.3, "output_kw_max": 29.6, "final_year_of_manufacture": 2011, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010112", "000005", "0", "2013/May/07 10:25", "Baxi Potterton", "Baxi", "Combi", "105 HE", "GC No. 47-075-18", "2004", "2011", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "29.6", "29.6", "", "", "85.8", "77.2", "", "54.3", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "", "", "0005", "", "", "", "", "", "", "", "", "87.6", "91.3", "", "", "", "", "90.6"]} +{"pcdb_id": 10113, "brand_name": "Potterton", "model_name": "Performa System", "model_qualifier": "28 HE", "winter_efficiency_pct": 87.7, "summer_efficiency_pct": 78.7, "comparative_hot_water_efficiency_pct": 57.5, "output_kw_max": 28.0, "final_year_of_manufacture": 2011, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010113", "000005", "0", "2013/May/07 10:25", "Baxi Potterton", "Potterton", "Performa System", "28 HE", "", "2004", "2011", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "28.0", "28.0", "", "", "87.7", "78.7", "", "57.5", "", "2", "0", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.4", "93.4", "", "", "", "", "92.6"]} +{"pcdb_id": 10114, "brand_name": "Potterton", "model_name": "Performa System", "model_qualifier": "28 HE", "winter_efficiency_pct": 85.7, "summer_efficiency_pct": 76.7, "comparative_hot_water_efficiency_pct": 56.0, "output_kw_max": 28.0, "final_year_of_manufacture": 2011, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010114", "000005", "0", "2013/May/07 10:25", "Baxi Potterton", "Potterton", "Performa System", "28 HE", "GC No. 41-591-27", "2004", "2011", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "28.0", "28.0", "", "", "85.7", "76.7", "", "56.0", "", "2", "", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.4", "91.3", "", "", "", "", "90.5"]} +{"pcdb_id": 10115, "brand_name": "Potterton", "model_name": "Performa System", "model_qualifier": "24 HE", "winter_efficiency_pct": 87.8, "summer_efficiency_pct": 78.8, "comparative_hot_water_efficiency_pct": 57.6, "output_kw_max": 24.0, "final_year_of_manufacture": 2011, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010115", "000005", "0", "2013/May/07 10:25", "Baxi Potterton", "Potterton", "Performa System", "24 HE", "", "2004", "2011", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "24.0", "24.0", "", "", "87.8", "78.8", "", "57.6", "", "2", "0", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.2", "93.7", "", "", "", "", "92.8"]} +{"pcdb_id": 10116, "brand_name": "Potterton", "model_name": "Performa System", "model_qualifier": "24 HE", "winter_efficiency_pct": 85.8, "summer_efficiency_pct": 76.8, "comparative_hot_water_efficiency_pct": 56.1, "output_kw_max": 24.0, "final_year_of_manufacture": 2011, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010116", "000005", "0", "2013/May/07 10:26", "Baxi Potterton", "Potterton", "Performa System", "24 HE", "GC No. 41-591-26", "2004", "2011", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24.0", "24.0", "", "", "85.8", "76.8", "", "56.1", "", "2", "", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.2", "91.5", "", "", "", "", "90.7"]} +{"pcdb_id": 10117, "brand_name": "Potterton", "model_name": "Performa System", "model_qualifier": "18 HE", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 18.0, "final_year_of_manufacture": 2011, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010117", "000005", "0", "2013/May/07 10:26", "Baxi Potterton", "Potterton", "Performa System", "18 HE", "", "2004", "2011", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "18.0", "18.0", "", "", "88.0", "79.0", "", "57.7", "", "2", "0", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.6", "94.4", "", "", "", "", "93.3"]} +{"pcdb_id": 10118, "brand_name": "Potterton", "model_name": "Performa System", "model_qualifier": "18 HE", "winter_efficiency_pct": 86.0, "summer_efficiency_pct": 77.0, "comparative_hot_water_efficiency_pct": 56.2, "output_kw_max": 18.0, "final_year_of_manufacture": 2011, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010118", "000005", "0", "2013/May/07 10:26", "Baxi Potterton", "Potterton", "Performa System", "18 HE", "GC No. 41-591-25", "2004", "2011", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18.0", "18.0", "", "", "86.0", "77.0", "", "56.2", "", "2", "", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "86.6", "92.3", "", "", "", "", "91.2"]} +{"pcdb_id": 10119, "brand_name": "Potterton", "model_name": "Performa System", "model_qualifier": "12 HE", "winter_efficiency_pct": 87.6, "summer_efficiency_pct": 78.6, "comparative_hot_water_efficiency_pct": 57.4, "output_kw_max": 12.0, "final_year_of_manufacture": 2011, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010119", "000005", "0", "2013/May/07 10:27", "Baxi Potterton", "Potterton", "Performa System", "12 HE", "", "2004", "2011", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "12", "12", "", "", "87.6", "78.6", "", "57.4", "", "2", "0", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.1", "93.6", "", "", "", "", "92.5"]} +{"pcdb_id": 10120, "brand_name": "Potterton", "model_name": "Performa System", "model_qualifier": "12 HE", "winter_efficiency_pct": 85.6, "summer_efficiency_pct": 76.6, "comparative_hot_water_efficiency_pct": 55.9, "output_kw_max": 12.0, "final_year_of_manufacture": 2011, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010120", "000005", "0", "2013/May/07 10:27", "Baxi Potterton", "Potterton", "Performa System", "12 HE", "GC No. 41-591-24", "2004", "2011", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "12.0", "12.0", "", "", "85.6", "76.6", "", "55.9", "", "2", "", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "86.1", "91.5", "", "", "", "", "90.4"]} +{"pcdb_id": 10121, "brand_name": "Potterton", "model_name": "Performa", "model_qualifier": "30 HE", "winter_efficiency_pct": 87.8, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 55.7, "output_kw_max": 29.6, "final_year_of_manufacture": 2012, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010121", "000005", "0", "2013/May/07 10:27", "Baxi Potterton", "Potterton", "Performa", "30 HE", "", "2004", "2012", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "29.6", "29.6", "", "", "87.8", "79.2", "", "55.7", "", "2", "0", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "", "", "0005", "", "", "", "", "", "", "", "", "89.5", "93.4", "", "", "", "", "92.7"]} +{"pcdb_id": 10122, "brand_name": "Potterton", "model_name": "Performa", "model_qualifier": "30 HE", "winter_efficiency_pct": 85.8, "summer_efficiency_pct": 77.2, "comparative_hot_water_efficiency_pct": 54.3, "output_kw_max": 29.6, "final_year_of_manufacture": 2012, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010122", "000005", "0", "2013/May/07 10:27", "Baxi Potterton", "Potterton", "Performa", "30 HE", "GC No. 47-393-13", "2004", "2012", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "29.6", "29.6", "", "", "85.8", "77.2", "", "54.3", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "", "", "0005", "", "", "", "", "", "", "", "", "87.6", "91.3", "", "", "", "", "90.6"]} +{"pcdb_id": 10123, "brand_name": "Potterton", "model_name": "Performa", "model_qualifier": "24i HE", "winter_efficiency_pct": 87.8, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 55.7, "output_kw_max": 24.0, "final_year_of_manufacture": 2008, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010123", "000005", "0", "2010/Nov/19 09:19", "Baxi Potterton", "Potterton", "Performa", "24i HE", "", "2004", "2008", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "87.8", "79.2", "", "55.7", "", "2", "0", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "", "", "0005", "", "", "", "", "", "", "", "", "89.2", "93.7", "", "", "", "", "92.8"]} +{"pcdb_id": 10124, "brand_name": "Potterton", "model_name": "Performa", "model_qualifier": "24i HE", "winter_efficiency_pct": 85.8, "summer_efficiency_pct": 77.2, "comparative_hot_water_efficiency_pct": 54.3, "output_kw_max": 24.0, "final_year_of_manufacture": 2008, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010124", "000005", "0", "2010/Nov/19 09:18", "Baxi Potterton", "Potterton", "Performa", "24i HE", "GC No. 47-393-12", "2004", "2008", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "85.8", "77.2", "", "54.3", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "", "", "0005", "", "", "", "", "", "", "", "", "87.2", "91.5", "", "", "", "", "90.7"]} +{"pcdb_id": 10125, "brand_name": "Potterton", "model_name": "Performa", "model_qualifier": "24 Eco HE", "winter_efficiency_pct": 87.8, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 55.7, "output_kw_max": 24.0, "final_year_of_manufacture": 2012, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010125", "000005", "0", "2013/May/07 10:27", "Baxi Potterton", "Potterton", "Performa", "24 Eco HE", "", "2004", "2012", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "87.8", "79.2", "", "55.7", "", "2", "0", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "", "", "0005", "", "", "", "", "", "", "", "", "89.2", "93.7", "", "", "", "", "92.8"]} +{"pcdb_id": 10126, "brand_name": "Potterton", "model_name": "Performa", "model_qualifier": "24 Eco HE", "winter_efficiency_pct": 85.8, "summer_efficiency_pct": 77.2, "comparative_hot_water_efficiency_pct": 54.3, "output_kw_max": 24.0, "final_year_of_manufacture": 2012, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010126", "000005", "0", "2013/May/07 10:27", "Baxi Potterton", "Potterton", "Performa", "24 Eco HE", "GC No. 47-393-11", "2004", "2012", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "85.8", "77.2", "", "54.3", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "", "", "0005", "", "", "", "", "", "", "", "", "87.2", "91.5", "", "", "", "", "90.7"]} +{"pcdb_id": 10127, "brand_name": "Mistral", "model_name": "CKUT4 - 1215", "model_qualifier": "Kitchen Utility", "winter_efficiency_pct": 87.2, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 44.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010127", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "CKUT4 - 1215", "Kitchen Utility", "", "2004", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "35.2", "44", "", "", "87.2", "79.4", "", "58.0", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "89.5", "93.2", "", "", "", "", "92.5"]} +{"pcdb_id": 10128, "brand_name": "Mistral", "model_name": "CKUT 3 - 9012", "model_qualifier": "Kitchen Utility", "winter_efficiency_pct": 87.2, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 35.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010128", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "CKUT 3 - 9012", "Kitchen Utility", "", "2004", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "26.4", "35.2", "", "", "87.2", "79.4", "", "58.0", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "89.5", "93.2", "", "", "", "", "92.5"]} +{"pcdb_id": 10129, "brand_name": "Mistral", "model_name": "CK4 - 1215", "model_qualifier": "Kitchen", "winter_efficiency_pct": 87.2, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 44.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010129", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "CK4 - 1215", "Kitchen", "", "2004", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "35.2", "44", "", "", "87.2", "79.4", "", "58.0", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "89.5", "93.2", "", "", "", "", "92.5"]} +{"pcdb_id": 10130, "brand_name": "Mistral", "model_name": "CK 3 - 9012", "model_qualifier": "Kitchen", "winter_efficiency_pct": 87.2, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 35.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010130", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "CK 3 - 9012", "Kitchen", "", "2004", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "26.4", "35.2", "", "", "87.2", "79.4", "", "58.0", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "89.5", "93.2", "", "", "", "", "92.5"]} +{"pcdb_id": 10131, "brand_name": "Mistral", "model_name": "CS3 - 9012", "model_qualifier": "Sealed System", "winter_efficiency_pct": 87.2, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 35.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010131", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "CS3 - 9012", "Sealed System", "", "2004", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "26.4", "35.2", "", "", "87.2", "79.4", "", "58.0", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "89.5", "93.2", "", "", "", "", "92.5"]} +{"pcdb_id": 10132, "brand_name": "Mistral", "model_name": "CS4 - 1215", "model_qualifier": "Sealed System", "winter_efficiency_pct": 87.2, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 44.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010132", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "CS4 - 1215", "Sealed System", "", "2004", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "35.2", "44", "", "", "87.2", "79.4", "", "58.0", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "89.5", "93.2", "", "", "", "", "92.5"]} +{"pcdb_id": 10133, "brand_name": "Mistral", "model_name": "CBH3 - 9012", "model_qualifier": "Boiler House", "winter_efficiency_pct": 87.2, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 35.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010133", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "CBH3 - 9012", "Boiler House", "", "2004", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "26.4", "35.2", "", "", "87.2", "79.4", "", "58.0", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "89.5", "93.2", "", "", "", "", "92.5"]} +{"pcdb_id": 10134, "brand_name": "Mistral", "model_name": "CBH4 - 1215", "model_qualifier": "Boiler House", "winter_efficiency_pct": 87.2, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 44.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010134", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "CBH4 - 1215", "Boiler House", "", "2004", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "35.2", "44", "", "", "87.2", "79.4", "", "58.0", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "89.5", "93.2", "", "", "", "", "92.5"]} +{"pcdb_id": 10135, "brand_name": "Mistral", "model_name": "COD3 - 9012", "model_qualifier": "Outdoor", "winter_efficiency_pct": 87.2, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 35.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010135", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "COD3 - 9012", "Outdoor", "", "2004", "current", "4", "1", "2", "1", "0", "", "", "2", "3", "1", "26.4", "35.2", "", "", "87.2", "79.4", "", "58.0", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "89.5", "93.2", "", "", "", "", "92.5"]} +{"pcdb_id": 10136, "brand_name": "Mistral", "model_name": "COD4 - 1215", "model_qualifier": "Outdoor", "winter_efficiency_pct": 87.2, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 44.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010136", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "COD4 - 1215", "Outdoor", "", "2004", "current", "4", "1", "2", "1", "0", "", "", "2", "3", "1", "35.2", "44", "", "", "87.2", "79.4", "", "58.0", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "89.5", "93.2", "", "", "", "", "92.5"]} +{"pcdb_id": 10137, "brand_name": "Mistral", "model_name": "COD3 - SS - 9012", "model_qualifier": "Outdoor Sealed System", "winter_efficiency_pct": 87.2, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 35.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010137", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "COD3 - SS - 9012", "Outdoor Sealed System", "", "2004", "current", "4", "1", "2", "1", "0", "", "", "2", "3", "1", "26.4", "35.2", "", "", "87.2", "79.4", "", "58.0", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "89.5", "93.2", "", "", "", "", "92.5"]} +{"pcdb_id": 10138, "brand_name": "Mistral", "model_name": "COD4 - SS - 1215", "model_qualifier": "Outdoor Sealed System", "winter_efficiency_pct": 87.2, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 44.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010138", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "COD4 - SS - 1215", "Outdoor Sealed System", "", "2004", "current", "4", "1", "2", "1", "0", "", "", "2", "3", "1", "35.2", "44", "", "", "87.2", "79.4", "", "58.0", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "89.5", "93.2", "", "", "", "", "92.5"]} +{"pcdb_id": 10139, "brand_name": "Mistral", "model_name": "CC3 - 9012", "model_qualifier": "Combi", "winter_efficiency_pct": 87.2, "summer_efficiency_pct": 81.1, "comparative_hot_water_efficiency_pct": 48.5, "output_kw_max": 35.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010139", "000056", "0", "2024/Jan/31 10:17", "Mistral Boilers", "Mistral", "CC3 - 9012", "Combi", "", "2004", "current", "4", "1", "1", "2", "0", "", "", "2", "3", "1", "26.4", "35.2", "", "", "87.2", "81.1", "", "48.5", "", "2", "", "", "203", "1", "1", "", "", "2", "", "0", "62", "0", "25", "3", "75", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "89.5", "93.3", "", "", "", "", "92.6"]} +{"pcdb_id": 10140, "brand_name": "Mistral", "model_name": "CC4 - 1215", "model_qualifier": "Combi", "winter_efficiency_pct": 87.2, "summer_efficiency_pct": 81.1, "comparative_hot_water_efficiency_pct": 48.5, "output_kw_max": 44.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010140", "000056", "0", "2024/Jan/31 10:17", "Mistral Boilers", "Mistral", "CC4 - 1215", "Combi", "", "2004", "current", "4", "1", "1", "2", "0", "", "", "2", "3", "1", "35.2", "44", "", "", "87.2", "81.1", "", "48.5", "", "2", "", "", "203", "1", "1", "", "", "2", "", "0", "62", "0", "25", "3", "75", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "89.5", "93.3", "", "", "", "", "92.6"]} +{"pcdb_id": 10141, "brand_name": "Mistral", "model_name": "COD3 - C - 9012", "model_qualifier": "Outdoor Combi", "winter_efficiency_pct": 87.2, "summer_efficiency_pct": 81.1, "comparative_hot_water_efficiency_pct": 48.5, "output_kw_max": 35.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010141", "000056", "0", "2024/Jan/31 10:17", "Mistral Boilers", "Mistral", "COD3 - C - 9012", "Outdoor Combi", "", "2004", "current", "4", "1", "2", "2", "0", "", "", "2", "3", "1", "26.4", "35.2", "", "", "87.2", "81.1", "", "48.5", "", "2", "", "", "203", "1", "1", "", "", "2", "", "0", "62", "0", "25", "3", "75", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "89.5", "93.3", "", "", "", "", "92.6"]} +{"pcdb_id": 10142, "brand_name": "Mistral", "model_name": "COD4 - C - 1215", "model_qualifier": "Outdoor Combi", "winter_efficiency_pct": 87.2, "summer_efficiency_pct": 81.1, "comparative_hot_water_efficiency_pct": 48.5, "output_kw_max": 44.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010142", "000056", "0", "2024/Jan/31 10:17", "Mistral Boilers", "Mistral", "COD4 - C - 1215", "Outdoor Combi", "", "2004", "current", "4", "1", "2", "2", "0", "", "", "2", "3", "1", "35.2", "44", "", "", "87.2", "81.1", "", "48.5", "", "2", "", "", "203", "1", "1", "", "", "2", "", "0", "62", "0", "25", "3", "75", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "89.5", "93.3", "", "", "", "", "92.6"]} +{"pcdb_id": 10143, "brand_name": "Mistral", "model_name": "OD-C2-7090", "model_qualifier": "Outdoor Combi", "winter_efficiency_pct": 81.5, "summer_efficiency_pct": 73.4, "comparative_hot_water_efficiency_pct": 45.0, "output_kw_max": 26.4, "final_year_of_manufacture": 2006, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010143", "000056", "0", "2024/Jan/31 10:17", "Mistral Boilers", "Mistral", "OD-C2-7090", "Outdoor Combi", "", "2004", "2006", "4", "1", "2", "2", "0", "", "", "1", "3", "1", "20.5", "26.4", "", "", "81.5", "73.4", "", "45.0", "", "2", "", "", "203", "1", "1", "", "", "2", "", "0", "37", "0", "25", "3", "75", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.9", "85.0", "", "", "", "", "84.4"]} +{"pcdb_id": 10144, "brand_name": "Mistral", "model_name": "OD-C1-5070", "model_qualifier": "Outdoor Combi", "winter_efficiency_pct": 81.5, "summer_efficiency_pct": 73.4, "comparative_hot_water_efficiency_pct": 45.0, "output_kw_max": 20.5, "final_year_of_manufacture": 2006, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010144", "000056", "0", "2024/Jan/31 10:17", "Mistral Boilers", "Mistral", "OD-C1-5070", "Outdoor Combi", "", "2004", "2006", "4", "1", "2", "2", "0", "", "", "1", "3", "1", "14.6", "20.5", "", "", "81.5", "73.4", "", "45.0", "", "2", "", "", "203", "1", "1", "", "", "2", "", "0", "37", "0", "25", "3", "75", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.9", "85.0", "", "", "", "", "84.4"]} +{"pcdb_id": 10145, "brand_name": "Mistral", "model_name": "C2-7090", "model_qualifier": "Combi", "winter_efficiency_pct": 81.5, "summer_efficiency_pct": 73.4, "comparative_hot_water_efficiency_pct": 45.0, "output_kw_max": 26.4, "final_year_of_manufacture": 2006, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010145", "000056", "0", "2024/Jan/31 10:17", "Mistral Boilers", "Mistral", "C2-7090", "Combi", "", "2004", "2006", "4", "1", "1", "2", "0", "", "", "1", "3", "1", "20.5", "26.4", "", "", "81.5", "73.4", "", "45.0", "", "2", "", "", "203", "1", "1", "", "", "2", "", "0", "37", "0", "25", "3", "75", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.9", "85.0", "", "", "", "", "84.4"]} +{"pcdb_id": 10147, "brand_name": "Mistral", "model_name": "C1-5070", "model_qualifier": "Combi", "winter_efficiency_pct": 81.5, "summer_efficiency_pct": 73.4, "comparative_hot_water_efficiency_pct": 45.0, "output_kw_max": 20.5, "final_year_of_manufacture": 2006, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010147", "000056", "0", "2024/Jan/31 10:17", "Mistral Boilers", "Mistral", "C1-5070", "Combi", "", "2004", "2006", "4", "1", "1", "2", "0", "", "", "1", "3", "1", "14.6", "20.5", "", "", "81.5", "73.4", "", "45.0", "", "2", "", "", "203", "1", "1", "", "", "2", "", "0", "37", "0", "25", "3", "75", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.9", "85.0", "", "", "", "", "84.4"]} +{"pcdb_id": 10148, "brand_name": "Mistral", "model_name": "OD1-SS-5070", "model_qualifier": "Outdoor Sealed System", "winter_efficiency_pct": 83.4, "summer_efficiency_pct": 71.7, "comparative_hot_water_efficiency_pct": 52.4, "output_kw_max": 20.5, "final_year_of_manufacture": 2006, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010148", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "OD1-SS-5070", "Outdoor Sealed System", "", "2004", "2006", "4", "1", "2", "1", "0", "", "", "1", "3", "1", "14.6", "20.5", "", "", "83.4", "71.7", "", "52.4", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.9", "85.0", "", "", "", "", "84.4"]} +{"pcdb_id": 10149, "brand_name": "Mistral", "model_name": "OD2-SS-7090", "model_qualifier": "Outdoor Sealed System", "winter_efficiency_pct": 83.4, "summer_efficiency_pct": 71.7, "comparative_hot_water_efficiency_pct": 52.4, "output_kw_max": 26.4, "final_year_of_manufacture": 2006, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010149", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "OD2-SS-7090", "Outdoor Sealed System", "", "2004", "2006", "4", "1", "2", "1", "0", "", "", "1", "3", "1", "20.5", "26.4", "", "", "83.4", "71.7", "", "52.4", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.9", "85.0", "", "", "", "", "84.4"]} +{"pcdb_id": 10150, "brand_name": "Mistral", "model_name": "S1-5070", "model_qualifier": "Sealed System", "winter_efficiency_pct": 83.4, "summer_efficiency_pct": 71.7, "comparative_hot_water_efficiency_pct": 52.4, "output_kw_max": 20.5, "final_year_of_manufacture": 2006, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010150", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "S1-5070", "Sealed System", "", "2004", "2006", "4", "1", "1", "1", "0", "", "", "1", "3", "1", "14.6", "20.5", "", "", "83.4", "71.7", "", "52.4", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.9", "85.0", "", "", "", "", "84.4"]} +{"pcdb_id": 10151, "brand_name": "Mistral", "model_name": "S2-7090", "model_qualifier": "Sealed System", "winter_efficiency_pct": 83.4, "summer_efficiency_pct": 71.7, "comparative_hot_water_efficiency_pct": 52.4, "output_kw_max": 26.4, "final_year_of_manufacture": 2006, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010151", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "S2-7090", "Sealed System", "", "2004", "2006", "4", "1", "1", "1", "0", "", "", "1", "3", "1", "20.5", "26.4", "", "", "83.4", "71.7", "", "52.4", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.9", "85.0", "", "", "", "", "84.4"]} +{"pcdb_id": 10152, "brand_name": "Mistral", "model_name": "OD1-5070", "model_qualifier": "Outdoor", "winter_efficiency_pct": 83.4, "summer_efficiency_pct": 71.7, "comparative_hot_water_efficiency_pct": 52.4, "output_kw_max": 20.5, "final_year_of_manufacture": 2006, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010152", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "OD1-5070", "Outdoor", "", "2004", "2006", "4", "1", "2", "1", "0", "", "", "1", "3", "1", "14.6", "20.5", "", "", "83.4", "71.7", "", "52.4", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.9", "85.0", "", "", "", "", "84.4"]} +{"pcdb_id": 10153, "brand_name": "Mistral", "model_name": "OD2-7090", "model_qualifier": "Outdoor", "winter_efficiency_pct": 83.4, "summer_efficiency_pct": 71.7, "comparative_hot_water_efficiency_pct": 52.4, "output_kw_max": 26.4, "final_year_of_manufacture": 2006, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010153", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "OD2-7090", "Outdoor", "", "2004", "2006", "4", "1", "2", "1", "0", "", "", "1", "3", "1", "20.5", "26.4", "", "", "83.4", "71.7", "", "52.4", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.9", "85.0", "", "", "", "", "84.4"]} +{"pcdb_id": 10154, "brand_name": "Mistral", "model_name": "K1-5070", "model_qualifier": "Kitchen", "winter_efficiency_pct": 83.4, "summer_efficiency_pct": 71.7, "comparative_hot_water_efficiency_pct": 52.4, "output_kw_max": 20.5, "final_year_of_manufacture": 2006, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010154", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "K1-5070", "Kitchen", "", "2004", "2006", "4", "1", "1", "1", "0", "", "", "1", "3", "1", "14.6", "20.5", "", "", "83.4", "71.7", "", "52.4", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.9", "85.0", "", "", "", "", "84.4"]} +{"pcdb_id": 10155, "brand_name": "Mistral", "model_name": "K2-7090", "model_qualifier": "Kitchen", "winter_efficiency_pct": 83.4, "summer_efficiency_pct": 71.7, "comparative_hot_water_efficiency_pct": 52.4, "output_kw_max": 26.4, "final_year_of_manufacture": 2006, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010155", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "K2-7090", "Kitchen", "", "2004", "2006", "4", "1", "1", "1", "0", "", "", "1", "3", "1", "20.5", "26.4", "", "", "83.4", "71.7", "", "52.4", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.9", "85.0", "", "", "", "", "84.4"]} +{"pcdb_id": 10156, "brand_name": "Mistral", "model_name": "BH2-7090", "model_qualifier": "Boiler House", "winter_efficiency_pct": 83.4, "summer_efficiency_pct": 71.7, "comparative_hot_water_efficiency_pct": 52.4, "output_kw_max": 26.4, "final_year_of_manufacture": 2006, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010156", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "BH2-7090", "Boiler House", "", "2004", "2006", "4", "1", "1", "1", "0", "", "", "1", "3", "1", "20.5", "26.4", "", "", "83.4", "71.7", "", "52.4", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.9", "85.0", "", "", "", "", "84.4"]} +{"pcdb_id": 10157, "brand_name": "Mistral", "model_name": "BH1-5070", "model_qualifier": "Boiler House", "winter_efficiency_pct": 83.4, "summer_efficiency_pct": 71.7, "comparative_hot_water_efficiency_pct": 52.4, "output_kw_max": 20.5, "final_year_of_manufacture": 2006, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010157", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "BH1-5070", "Boiler House", "", "2004", "2006", "4", "1", "1", "1", "0", "", "", "1", "3", "1", "14.6", "20.5", "", "", "83.4", "71.7", "", "52.4", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.9", "85.0", "", "", "", "", "84.4"]} +{"pcdb_id": 10158, "brand_name": "Mistral", "model_name": "KUT1 5070", "model_qualifier": "Kitchen Utility", "winter_efficiency_pct": 83.4, "summer_efficiency_pct": 71.7, "comparative_hot_water_efficiency_pct": 52.4, "output_kw_max": 20.5, "final_year_of_manufacture": 2006, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010158", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "KUT1 5070", "Kitchen Utility", "", "2004", "2006", "4", "1", "1", "1", "0", "", "", "1", "3", "1", "14.6", "20.5", "", "", "83.4", "71.7", "", "52.4", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.9", "85.0", "", "", "", "", "84.4"]} +{"pcdb_id": 10159, "brand_name": "Mistral", "model_name": "KUT2-7090", "model_qualifier": "Kitchen Utility", "winter_efficiency_pct": 83.4, "summer_efficiency_pct": 71.7, "comparative_hot_water_efficiency_pct": 52.4, "output_kw_max": 26.4, "final_year_of_manufacture": 2006, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010159", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "KUT2-7090", "Kitchen Utility", "", "2004", "2006", "4", "1", "1", "1", "0", "", "", "1", "3", "1", "20.5", "26.4", "", "", "83.4", "71.7", "", "52.4", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.9", "85.0", "", "", "", "", "84.4"]} +{"pcdb_id": 10160, "brand_name": "Vokera", "model_name": "Syntesi", "model_qualifier": "29e", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 56.0, "output_kw_max": 28.77, "final_year_of_manufacture": 2010, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010160", "000011", "0", "2010/Oct/21 11:09", "Vokera", "Vokera", "Syntesi", "29e", "4709448", "2004", "2010", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28.77", "28.77", "", "", "88.3", "79.7", "", "56.0", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.4", "96.9", "", "", "", "", "95.4"]} +{"pcdb_id": 10161, "brand_name": "Vokera", "model_name": "Synergy", "model_qualifier": "29e", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 28.77, "final_year_of_manufacture": 2010, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010161", "000011", "0", "2012/Mar/27 10:12", "Vokera", "Vokera", "Synergy", "29e", "4109427", "2004", "2010", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "28.77", "28.77", "", "", "88.3", "79.3", "", "57.9", "", "2", "", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.4", "96.9", "", "", "", "", "95.4"]} +{"pcdb_id": 10162, "brand_name": "Potterton", "model_name": "Suprima", "model_qualifier": "30 HE", "winter_efficiency_pct": 84.0, "summer_efficiency_pct": 76.4, "comparative_hot_water_efficiency_pct": 55.8, "output_kw_max": 8.82, "final_year_of_manufacture": 2011, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010162", "000005", "0", "2013/May/07 10:28", "Baxi Potterton", "Potterton", "Suprima", "30 HE", "GC No. 41-075-35", "2004", "2011", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "8.82", "8.82", "", "", "84.0", "76.4", "", "55.8", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "86.3", "90.9", "", "", "", "", "90.0"]} +{"pcdb_id": 10163, "brand_name": "Potterton", "model_name": "Suprima", "model_qualifier": "40 HE", "winter_efficiency_pct": 84.2, "summer_efficiency_pct": 76.6, "comparative_hot_water_efficiency_pct": 55.9, "output_kw_max": 11.78, "final_year_of_manufacture": 2011, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010163", "000005", "0", "2013/May/07 10:28", "Baxi Potterton", "Potterton", "Suprima", "40 HE", "GC No. 41-075-36", "2004", "2011", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "11.78", "11.78", "", "", "84.2", "76.6", "", "55.9", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "86.5", "91.3", "", "", "", "", "90.4"]} +{"pcdb_id": 10164, "brand_name": "Potterton", "model_name": "Suprima", "model_qualifier": "50 HE", "winter_efficiency_pct": 84.0, "summer_efficiency_pct": 76.4, "comparative_hot_water_efficiency_pct": 55.8, "output_kw_max": 14.76, "final_year_of_manufacture": 2011, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010164", "000005", "0", "2013/May/07 10:28", "Baxi Potterton", "Potterton", "Suprima", "50 HE", "GC No. 41-075-37", "2004", "2011", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "14.76", "14.76", "", "", "84.0", "76.4", "", "55.8", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "86.7", "90.7", "", "", "", "", "90.0"]} +{"pcdb_id": 10165, "brand_name": "Potterton", "model_name": "Suprima", "model_qualifier": "60 HE", "winter_efficiency_pct": 84.0, "summer_efficiency_pct": 76.4, "comparative_hot_water_efficiency_pct": 55.8, "output_kw_max": 17.72, "final_year_of_manufacture": 2011, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010165", "000005", "0", "2013/May/07 10:28", "Baxi Potterton", "Potterton", "Suprima", "60 HE", "GC No. 41-075-38", "2004", "2011", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "17.72", "17.72", "", "", "84.0", "76.4", "", "55.8", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "86.8", "90.6", "", "", "", "", "89.9"]} +{"pcdb_id": 10166, "brand_name": "Potterton", "model_name": "Suprima", "model_qualifier": "70 HE", "winter_efficiency_pct": 84.0, "summer_efficiency_pct": 76.4, "comparative_hot_water_efficiency_pct": 55.8, "output_kw_max": 20.68, "final_year_of_manufacture": 2011, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010166", "000005", "0", "2013/May/07 10:28", "Baxi Potterton", "Potterton", "Suprima", "70 HE", "GC No. 41-075-39", "2004", "2011", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "20.68", "20.68", "", "", "84.0", "76.4", "", "55.8", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "86.8", "90.7", "", "", "", "", "90.0"]} +{"pcdb_id": 10167, "brand_name": "Potterton", "model_name": "Suprima", "model_qualifier": "80 HE", "winter_efficiency_pct": 84.0, "summer_efficiency_pct": 76.4, "comparative_hot_water_efficiency_pct": 55.8, "output_kw_max": 23.63, "final_year_of_manufacture": 2011, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010167", "000005", "0", "2013/May/07 10:28", "Baxi Potterton", "Potterton", "Suprima", "80 HE", "GC No. 41-075-40", "2004", "2011", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "23.63", "23.63", "", "", "84.0", "76.4", "", "55.8", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "86.8", "90.6", "", "", "", "", "89.9"]} +{"pcdb_id": 10168, "brand_name": "Grant", "model_name": "Vortex", "model_qualifier": "Outdoor Module 36-46", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 46.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010168", "000048", "0", "2012/Mar/27 10:12", "Grant Engineering (UK)", "Grant", "Vortex", "Outdoor Module 36-46", "", "2004", "current", "4", "1", "2", "1", "0", "", "", "2", "1", "2", "36", "46", "", "", "87.9", "80.1", "", "58.5", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.8", "94.4", "", "", "", "", "93.8"]} +{"pcdb_id": 10169, "brand_name": "Grant", "model_name": "Vortex", "model_qualifier": "Outdoor Module 26-36", "winter_efficiency_pct": 90.5, "summer_efficiency_pct": 82.7, "comparative_hot_water_efficiency_pct": 60.4, "output_kw_max": 36.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010169", "000048", "0", "2012/Mar/27 10:12", "Grant Engineering (UK)", "Grant", "Vortex", "Outdoor Module 26-36", "", "2004", "current", "4", "1", "2", "1", "0", "", "", "2", "1", "2", "26", "36", "", "", "90.5", "82.7", "", "60.4", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "95.1", "99.3", "", "", "", "", "98.5"]} +{"pcdb_id": 10170, "brand_name": "Grant", "model_name": "Vortex", "model_qualifier": "Outdoor Module 15-26", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 81.3, "comparative_hot_water_efficiency_pct": 59.4, "output_kw_max": 26.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010170", "000048", "0", "2012/Mar/27 10:12", "Grant Engineering (UK)", "Grant", "Vortex", "Outdoor Module 15-26", "", "2004", "current", "4", "1", "2", "1", "0", "", "", "2", "1", "2", "15", "26", "", "", "89.1", "81.3", "", "59.4", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "93.6", "96.4", "", "", "", "", "95.9"]} +{"pcdb_id": 10171, "brand_name": "Grant", "model_name": "Vortex", "model_qualifier": "Utility 36-46", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 46.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010171", "000048", "0", "2012/Mar/27 10:12", "Grant Engineering (UK)", "Grant", "Vortex", "Utility 36-46", "", "2004", "current", "4", "1", "1", "1", "0", "", "", "2", "2", "2", "36", "46", "", "", "87.9", "80.1", "", "58.5", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.8", "94.4", "", "", "", "", "93.8"]} +{"pcdb_id": 10172, "brand_name": "Grant", "model_name": "Vortex", "model_qualifier": "Utility System 36-46S", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 46.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010172", "000048", "0", "2012/Mar/27 10:12", "Grant Engineering (UK)", "Grant", "Vortex", "Utility System 36-46S", "", "2004", "current", "4", "1", "1", "1", "0", "", "", "2", "2", "2", "36", "46", "", "", "87.9", "80.1", "", "58.5", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.8", "94.4", "", "", "", "", "93.8"]} +{"pcdb_id": 10173, "brand_name": "Trianco", "model_name": "Contractor 100/125", "model_qualifier": "", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 36.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010173", "000062", "0", "2012/Mar/27 10:12", "Trianco", "Trianco", "Contractor 100/125", "", "2301", "2004", "current", "4", "1", "1", "1", "0", "", "", "1", "3", "1", "29.3", "36.6", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "148", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.4", "90.5", "", "", "", "", "89.7"]} +{"pcdb_id": 10174, "brand_name": "Trianco", "model_name": "Contractor 50/90", "model_qualifier": "", "winter_efficiency_pct": 86.6, "summer_efficiency_pct": 74.9, "comparative_hot_water_efficiency_pct": 54.7, "output_kw_max": 26.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010174", "000062", "0", "2012/Mar/27 10:12", "Trianco", "Trianco", "Contractor 50/90", "", "2300", "2004", "current", "4", "1", "1", "1", "0", "", "", "1", "3", "1", "14.7", "26.4", "", "", "86.6", "74.9", "", "54.7", "", "2", "", "", "201", "1", "1", "148", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.2", "87.0", "", "", "", "", "86.8"]} +{"pcdb_id": 10175, "brand_name": "HRM Boilers", "model_name": "Wallstar System", "model_qualifier": "12/15 System 11", "winter_efficiency_pct": 86.4, "summer_efficiency_pct": 74.7, "comparative_hot_water_efficiency_pct": 54.6, "output_kw_max": 15.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010175", "000098", "0", "2012/Mar/27 10:12", "HRM Boilers", "HRM Boilers", "Wallstar System", "12/15 System 11", "", "2004", "current", "4", "2", "1", "1", "0", "", "", "1", "2", "2", "12", "15", "", "", "86.4", "74.7", "", "54.6", "", "2", "", "", "201", "1", "1", "240", "100", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.6", "86.6", "", "", "", "", "86.6"]} +{"pcdb_id": 10178, "brand_name": "Glow-worm", "model_name": "30sxi", "model_qualifier": "", "winter_efficiency_pct": 90.0, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 59.2, "output_kw_max": 28.17, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010178", "000207", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Glow-worm", "30sxi", "", "GC 41-047-62", "2002", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "28.17", "28.17", "", "", "90.0", "81.0", "", "59.2", "", "2", "0", "", "102", "1", "2", "180", "15", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.8", "99.0", "", "", "", "", "97.3"]} +{"pcdb_id": 10179, "brand_name": "Ariston", "model_name": "ACO 27 MFFI", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 55.9, "output_kw_max": 22.5, "final_year_of_manufacture": 2007, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010179", "000080", "0", "2008/Jun/26 09:07", "Merloni TermoSanitari SpA", "Ariston", "ACO 27 MFFI", "", "GC No 47-116-34", "2004", "2007", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "22.5", "22.5", "", "", "88.1", "79.5", "", "55.9", "", "2", "", "", "104", "1", "2", "118", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.6", "96.9", "", "", "", "", "95.3"]} +{"pcdb_id": 10180, "brand_name": "DD Heating", "model_name": "Heatline", "model_qualifier": "Solaris 24PC", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 55.8, "output_kw_max": 24.42, "final_year_of_manufacture": 2009, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010180", "000215", "0", "2011/Aug/31 10:34", "Turk Demir Dokum Fab AS", "DD Heating", "Heatline", "Solaris 24PC", "", "2004", "2009", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.42", "24.42", "", "", "88.0", "79.4", "", "55.8", "", "2", "", "", "104", "1", "2", "140", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "96.8", "", "", "", "", "95.1"]} +{"pcdb_id": 10181, "brand_name": "DD Heating", "model_name": "Heatline", "model_qualifier": "C24", "winter_efficiency_pct": 84.9, "summer_efficiency_pct": 76.3, "comparative_hot_water_efficiency_pct": 53.6, "output_kw_max": 24.82, "final_year_of_manufacture": 2007, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010181", "000215", "0", "2011/Aug/31 10:43", "Turk Demir Dokum Fab AS", "DD Heating", "Heatline", "C24", "", "2004", "2007", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.82", "24.82", "", "", "84.9", "76.3", "", "53.6", "", "2", "", "", "104", "1", "2", "196", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.0", "89.3", "", "", "", "", "88.9"]} +{"pcdb_id": 10183, "brand_name": "Mistral", "model_name": "OD4-C-1215", "model_qualifier": "Outdoor Mega Combi", "winter_efficiency_pct": 83.0, "summer_efficiency_pct": 74.9, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 44.0, "final_year_of_manufacture": 2006, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010183", "000056", "0", "2024/Jan/31 10:17", "Mistral Boilers", "Mistral", "OD4-C-1215", "Outdoor Mega Combi", "", "2004", "2006", "4", "1", "2", "2", "0", "", "", "1", "3", "1", "35.2", "44", "", "", "83.0", "74.9", "", "40.8", "", "2", "", "", "203", "1", "1", "", "", "2", "", "0", "70", "0", "20", "3", "80", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "84.8", "85.0", "", "", "", "", "85.0"]} +{"pcdb_id": 10184, "brand_name": "Mistral", "model_name": "OD3-C-9012", "model_qualifier": "Outdoor Mega Combi", "winter_efficiency_pct": 83.0, "summer_efficiency_pct": 74.9, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 35.2, "final_year_of_manufacture": 2006, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010184", "000056", "0", "2024/Jan/31 10:17", "Mistral Boilers", "Mistral", "OD3-C-9012", "Outdoor Mega Combi", "", "2004", "2006", "4", "1", "2", "2", "0", "", "", "1", "3", "1", "26.4", "35.2", "", "", "83.0", "74.9", "", "40.8", "", "2", "", "", "203", "1", "1", "", "", "2", "", "0", "70", "0", "20", "3", "80", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "84.8", "85.0", "", "", "", "", "85.0"]} +{"pcdb_id": 10185, "brand_name": "Mistral", "model_name": "C4-1215", "model_qualifier": "Mega Combi", "winter_efficiency_pct": 83.0, "summer_efficiency_pct": 74.9, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 44.0, "final_year_of_manufacture": 2006, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010185", "000056", "0", "2024/Jan/31 10:17", "Mistral Boilers", "Mistral", "C4-1215", "Mega Combi", "", "2004", "2006", "4", "1", "1", "2", "0", "", "", "1", "3", "1", "35.2", "44", "", "", "83.0", "74.9", "", "40.8", "", "2", "", "", "203", "1", "1", "", "", "2", "", "0", "70", "0", "20", "3", "90", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "84.8", "85.0", "", "", "", "", "85.0"]} +{"pcdb_id": 10187, "brand_name": "Mistral", "model_name": "C3-9012", "model_qualifier": "Mega Combi", "winter_efficiency_pct": 83.0, "summer_efficiency_pct": 74.9, "comparative_hot_water_efficiency_pct": 38.6, "output_kw_max": 35.2, "final_year_of_manufacture": 2006, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010187", "000056", "0", "2024/Jan/31 10:17", "Mistral Boilers", "Mistral", "C3-9012", "Mega Combi", "", "2004", "2006", "4", "1", "1", "2", "0", "", "", "1", "3", "1", "26.4", "35.2", "", "", "83.0", "74.9", "", "38.6", "", "2", "", "", "203", "1", "1", "", "", "2", "", "0", "90", "0", "20", "3", "80", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "84.8", "85.0", "", "", "", "", "85.0"]} +{"pcdb_id": 10188, "brand_name": "Mistral", "model_name": "OD4-SS-1215", "model_qualifier": "Outdoor Sealed System", "winter_efficiency_pct": 84.9, "summer_efficiency_pct": 73.2, "comparative_hot_water_efficiency_pct": 53.5, "output_kw_max": 44.0, "final_year_of_manufacture": 2006, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010188", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "OD4-SS-1215", "Outdoor Sealed System", "", "2004", "2006", "4", "1", "2", "1", "0", "", "", "1", "3", "1", "35.2", "44", "", "", "84.9", "73.2", "", "53.5", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "84.8", "85.0", "", "", "", "", "85.0"]} +{"pcdb_id": 10189, "brand_name": "Mistral", "model_name": "OD3-SS-9012", "model_qualifier": "Outdoor Sealed System", "winter_efficiency_pct": 84.9, "summer_efficiency_pct": 73.2, "comparative_hot_water_efficiency_pct": 53.5, "output_kw_max": 35.2, "final_year_of_manufacture": 2006, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010189", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "OD3-SS-9012", "Outdoor Sealed System", "", "2004", "2006", "4", "1", "2", "1", "0", "", "", "1", "3", "1", "26.4", "35.2", "", "", "84.9", "73.2", "", "53.5", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "84.8", "85.0", "", "", "", "", "85.0"]} +{"pcdb_id": 10190, "brand_name": "Mistral", "model_name": "OD4 - 1215", "model_qualifier": "Outdoor Model", "winter_efficiency_pct": 84.9, "summer_efficiency_pct": 73.2, "comparative_hot_water_efficiency_pct": 53.5, "output_kw_max": 44.0, "final_year_of_manufacture": 2006, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010190", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "OD4 - 1215", "Outdoor Model", "", "2004", "2006", "4", "1", "2", "1", "0", "", "", "1", "3", "1", "35.2", "44", "", "", "84.9", "73.2", "", "53.5", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "84.8", "85.0", "", "", "", "", "85.0"]} +{"pcdb_id": 10191, "brand_name": "Mistral", "model_name": "OD3-9012", "model_qualifier": "Outdoor Model", "winter_efficiency_pct": 84.9, "summer_efficiency_pct": 73.2, "comparative_hot_water_efficiency_pct": 53.5, "output_kw_max": 35.2, "final_year_of_manufacture": 2006, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010191", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "OD3-9012", "Outdoor Model", "", "2004", "2006", "4", "1", "2", "1", "0", "", "", "1", "3", "1", "26.4", "35.2", "", "", "84.9", "73.2", "", "53.5", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "84.8", "85.0", "", "", "", "", "85.0"]} +{"pcdb_id": 10192, "brand_name": "Mistral", "model_name": "BH4-1215", "model_qualifier": "Boiler House", "winter_efficiency_pct": 84.9, "summer_efficiency_pct": 73.2, "comparative_hot_water_efficiency_pct": 53.5, "output_kw_max": 44.0, "final_year_of_manufacture": 2006, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010192", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "BH4-1215", "Boiler House", "", "2004", "2006", "4", "1", "1", "1", "0", "", "", "1", "3", "1", "35.2", "44", "", "", "84.9", "73.2", "", "53.5", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "84.8", "85.0", "", "", "", "", "85.0"]} +{"pcdb_id": 10193, "brand_name": "Mistral", "model_name": "BH3-9012", "model_qualifier": "Boiler House", "winter_efficiency_pct": 84.9, "summer_efficiency_pct": 73.2, "comparative_hot_water_efficiency_pct": 53.5, "output_kw_max": 35.2, "final_year_of_manufacture": 2006, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010193", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "BH3-9012", "Boiler House", "", "2004", "2006", "4", "1", "1", "1", "0", "", "", "1", "3", "1", "26.4", "35.2", "", "", "84.9", "73.2", "", "53.5", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "84.8", "85.0", "", "", "", "", "85.0"]} +{"pcdb_id": 10194, "brand_name": "Mistral", "model_name": "S4-1215", "model_qualifier": "Sealed System", "winter_efficiency_pct": 84.9, "summer_efficiency_pct": 73.2, "comparative_hot_water_efficiency_pct": 53.5, "output_kw_max": 44.0, "final_year_of_manufacture": 2006, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010194", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "S4-1215", "Sealed System", "", "2004", "2006", "4", "1", "1", "1", "0", "", "", "1", "3", "1", "35.2", "44", "", "", "84.9", "73.2", "", "53.5", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "84.8", "85.0", "", "", "", "", "85.0"]} +{"pcdb_id": 10195, "brand_name": "Mistral", "model_name": "S3-9012", "model_qualifier": "Sealed System", "winter_efficiency_pct": 84.9, "summer_efficiency_pct": 73.2, "comparative_hot_water_efficiency_pct": 53.5, "output_kw_max": 35.2, "final_year_of_manufacture": 2006, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010195", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "S3-9012", "Sealed System", "", "2004", "2006", "4", "1", "1", "1", "0", "", "", "1", "3", "1", "26.4", "35.2", "", "", "84.9", "73.2", "", "53.5", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "84.8", "85.0", "", "", "", "", "85.0"]} +{"pcdb_id": 10196, "brand_name": "Mistral", "model_name": "K4-1215", "model_qualifier": "Kitchen", "winter_efficiency_pct": 84.9, "summer_efficiency_pct": 73.2, "comparative_hot_water_efficiency_pct": 53.5, "output_kw_max": 44.0, "final_year_of_manufacture": 2006, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010196", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "K4-1215", "Kitchen", "", "2004", "2006", "4", "1", "1", "1", "0", "", "", "1", "3", "1", "35.2", "44", "", "", "84.9", "73.2", "", "53.5", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "84.8", "85.0", "", "", "", "", "85.0"]} +{"pcdb_id": 10197, "brand_name": "Mistral", "model_name": "K3-9012", "model_qualifier": "Kitchen", "winter_efficiency_pct": 84.9, "summer_efficiency_pct": 73.2, "comparative_hot_water_efficiency_pct": 53.5, "output_kw_max": 35.2, "final_year_of_manufacture": 2006, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010197", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "K3-9012", "Kitchen", "", "2004", "2006", "4", "1", "1", "1", "0", "", "", "1", "3", "1", "26.4", "35.2", "", "", "84.9", "73.2", "", "53.5", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "84.8", "85.0", "", "", "", "", "85.0"]} +{"pcdb_id": 10198, "brand_name": "Mistral", "model_name": "KUT3-9012", "model_qualifier": "Kitchen Utility", "winter_efficiency_pct": 84.9, "summer_efficiency_pct": 73.2, "comparative_hot_water_efficiency_pct": 53.5, "output_kw_max": 35.2, "final_year_of_manufacture": 2006, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010198", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "KUT3-9012", "Kitchen Utility", "", "2004", "2006", "4", "1", "1", "1", "0", "", "", "1", "3", "1", "26.4", "35.2", "", "", "84.9", "73.2", "", "53.5", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "84.8", "85.0", "", "", "", "", "85.0"]} +{"pcdb_id": 10199, "brand_name": "Mistral", "model_name": "KUT4-1215", "model_qualifier": "Kitchen Utility", "winter_efficiency_pct": 84.9, "summer_efficiency_pct": 73.2, "comparative_hot_water_efficiency_pct": 53.5, "output_kw_max": 44.0, "final_year_of_manufacture": 2006, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010199", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "KUT4-1215", "Kitchen Utility", "", "2004", "2006", "4", "1", "1", "1", "0", "", "", "1", "3", "1", "35.2", "44", "", "", "84.9", "73.2", "", "53.5", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "84.8", "85.0", "", "", "", "", "85.0"]} +{"pcdb_id": 10200, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "12 Ri", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 12.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010200", "000035", "0", "2020/Sep/04 08:08", "Worcester Heat Systems", "Worcester", "Greenstar", "12 Ri", "41-311-63", "2004", "2015", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "12.00", "12.00", "", "", "88.1", "79.1", "", "57.7", "", "2", "", "", "102", "1", "2", "50", "5", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "97.0", "", "", "", "", "95.3"]} +{"pcdb_id": 10201, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "24 Ri", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 24.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010201", "000035", "0", "2020/Sep/04 08:08", "Worcester Heat Systems", "Worcester", "Greenstar", "24 Ri", "41-311-65", "2004", "2015", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24", "24", "", "", "88.5", "79.5", "", "58.0", "", "2", "", "", "102", "1", "2", "50", "5", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "97.9", "", "", "", "", "96.1"]} +{"pcdb_id": 10202, "brand_name": "Worcester", "model_name": "Greenstar Highflow", "model_qualifier": "440", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 43.8, "output_kw_max": 29.2, "final_year_of_manufacture": 2008, "subsidiary_type": 0, "store_type": 1, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010202", "000035", "0", "2024/Jan/31 10:17", "Worcester Heat Systems", "Worcester", "Greenstar Highflow", "440", "47 311 82", "2004", "2008", "1", "1", "1", "2", "0", "", "", "2", "2", "2", "29.2", "29.2", "", "", "88.1", "80.8", "", "43.8", "", "2", "", "", "106", "1", "2", "107", "10", "1", "1", "0", "47", "0", "25", "3", "75", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0305", "", "", "", "", "", "", "", "", "88.9", "96.8", "", "", "", "", "95.3"]} +{"pcdb_id": 10203, "brand_name": "Worcester", "model_name": "Greenstar Highflow", "model_qualifier": "440", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 81.8, "comparative_hot_water_efficiency_pct": 44.3, "output_kw_max": 29.2, "final_year_of_manufacture": 2008, "subsidiary_type": 0, "store_type": 1, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010203", "000035", "0", "2024/Jan/31 10:17", "Worcester Heat Systems", "Worcester", "Greenstar Highflow", "440", "47 311 83", "2004", "2008", "2", "1", "1", "2", "0", "", "", "2", "2", "2", "29.2", "29.2", "", "", "89.1", "81.8", "", "44.3", "", "2", "1", "", "106", "1", "2", "107", "10", "1", "1", "0", "47", "0", "25", "3", "75", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0305", "", "", "", "", "", "", "", "", "90.9", "98.9", "", "", "", "", "97.4"]} +{"pcdb_id": 10204, "brand_name": "Vaillant", "model_name": "Ecomax", "model_qualifier": "635E", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 34.9, "final_year_of_manufacture": 2010, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010204", "000031", "0", "2012/Mar/27 10:12", "Vaillant", "Vaillant", "Ecomax", "635E", "VU GB 356-C", "2004", "2010", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "34.9", "34.9", "", "", "88.5", "79.5", "", "58.0", "", "2", "", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.0", "97.1", "", "", "", "", "95.8"]} +{"pcdb_id": 10205, "brand_name": "Radiant", "model_name": "Radiant", "model_qualifier": "RBS 24", "winter_efficiency_pct": 79.9, "summer_efficiency_pct": 69.8, "comparative_hot_water_efficiency_pct": 49.1, "output_kw_max": 23.45, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010205", "000088", "0", "2006/Jan/17 12:31", "Radiant Bruciatori SpA", "Radiant", "Radiant", "RBS 24", "", "2004", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "23.45", "23.45", "", "", "79.9", "69.8", "", "49.1", "", "2", "", "", "104", "1", "2", "170", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.5", "79.7", "", "", "", "", "80.3"]} +{"pcdb_id": 10206, "brand_name": "Halstead", "model_name": "Wickes Combi HE 24", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 56.4, "output_kw_max": 19.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010206", "000019", "0", "2006/Jan/17 12:31", "Halstead Boilers", "Halstead", "Wickes Combi HE 24", "", "4726008", "2004", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "19.3", "19.3", "", "", "88.8", "80.2", "", "56.4", "", "2", "", "", "104", "1", "2", "190", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.1", "98.7", "", "", "", "", "96.7"]} +{"pcdb_id": 10207, "brand_name": "Halstead", "model_name": "Eden CBX 32", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 62.3, "output_kw_max": 25.7, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010207", "000019", "0", "2006/Jan/17 12:31", "Halstead Boilers", "Halstead", "Eden CBX 32", "", "4726004", "2004", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "25.7", "25.7", "", "", "88.4", "79.8", "", "62.3", "", "2", "", "", "104", "1", "2", "190", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "", "0005", "", "", "", "", "", "", "", "", "89.4", "97.1", "", "", "", "", "95.7"]} +{"pcdb_id": 10208, "brand_name": "Halstead", "model_name": "Eden CBX 24", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 62.6, "output_kw_max": 19.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010208", "000019", "0", "2006/Jan/17 12:31", "Halstead Boilers", "Halstead", "Eden CBX 24", "", "4726005", "2004", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "19.3", "19.3", "", "", "88.8", "80.2", "", "62.6", "", "2", "", "", "104", "1", "2", "190", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "", "0005", "", "", "", "", "", "", "", "", "88.1", "98.7", "", "", "", "", "96.7"]} +{"pcdb_id": 10209, "brand_name": "Halstead", "model_name": "Eden SBX 30", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 32.1, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010209", "000019", "0", "2012/Mar/27 10:12", "Halstead Boilers", "Halstead", "Eden SBX 30", "", "4126013", "2004", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "32.1", "32.1", "", "", "88.8", "79.8", "", "58.3", "", "2", "", "", "102", "1", "2", "190", "5", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "98.7", "", "", "", "", "96.7"]} +{"pcdb_id": 10210, "brand_name": "Halstead", "model_name": "Eden VBX 18", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 19.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010210", "000019", "0", "2012/Mar/27 10:12", "Halstead Boilers", "Halstead", "Eden VBX 18", "", "4126015", "2004", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "19.3", "19.3", "", "", "88.8", "79.8", "", "58.3", "", "2", "", "", "102", "1", "2", "110", "5", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.1", "98.7", "", "", "", "", "96.7"]} +{"pcdb_id": 10211, "brand_name": "Halstead", "model_name": "Eden VBX 30", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 32.1, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010211", "000019", "0", "2012/Mar/27 10:12", "Halstead Boilers", "Halstead", "Eden VBX 30", "", "4126014", "2004", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "32.1", "32.1", "", "", "88.8", "79.8", "", "58.3", "", "2", "", "", "102", "1", "2", "110", "5", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "98.7", "", "", "", "", "96.7"]} +{"pcdb_id": 10212, "brand_name": "Halstead", "model_name": "Eden CBX 32", "model_qualifier": "", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 63.0, "output_kw_max": 25.7, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010212", "000019", "0", "2006/Jan/17 12:31", "Halstead Boilers", "Halstead", "Eden CBX 32", "", "4726006", "2004", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "25.7", "25.7", "", "", "89.4", "80.8", "", "63.0", "", "2", "1", "", "104", "1", "2", "190", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "", "0005", "", "", "", "", "", "", "", "", "91.4", "99.3", "", "", "", "", "97.8"]} +{"pcdb_id": 10213, "brand_name": "Halstead", "model_name": "Eden CBX 24", "model_qualifier": "", "winter_efficiency_pct": 89.8, "summer_efficiency_pct": 81.2, "comparative_hot_water_efficiency_pct": 63.4, "output_kw_max": 19.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010213", "000019", "0", "2006/Jan/17 12:31", "Halstead Boilers", "Halstead", "Eden CBX 24", "", "4726007", "2004", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "19.3", "19.3", "", "", "89.8", "81.2", "", "63.4", "", "2", "1", "", "104", "1", "2", "190", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "", "0005", "", "", "", "", "", "", "", "", "90.1", "100.8", "", "", "", "", "98.8"]} +{"pcdb_id": 10214, "brand_name": "Halstead", "model_name": "Eden SBX 30", "model_qualifier": "", "winter_efficiency_pct": 89.8, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 59.0, "output_kw_max": 32.1, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010214", "000019", "0", "2012/Mar/27 10:12", "Halstead Boilers", "Halstead", "Eden SBX 30", "", "4126016", "2004", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "32.1", "32.1", "", "", "89.8", "80.8", "", "59.0", "", "2", "1", "", "102", "1", "2", "190", "5", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.3", "100.8", "", "", "", "", "98.8"]} +{"pcdb_id": 10215, "brand_name": "Halstead", "model_name": "Eden VBX 18", "model_qualifier": "", "winter_efficiency_pct": 89.8, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 59.0, "output_kw_max": 19.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010215", "000019", "0", "2012/Mar/27 10:12", "Halstead Boilers", "Halstead", "Eden VBX 18", "", "4126018", "2004", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "19.3", "19.3", "", "", "89.8", "80.8", "", "59.0", "", "2", "1", "", "102", "1", "2", "110", "5", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.1", "100.8", "", "", "", "", "98.8"]} +{"pcdb_id": 10216, "brand_name": "Halstead", "model_name": "Eden VBX 30", "model_qualifier": "", "winter_efficiency_pct": 89.8, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 59.0, "output_kw_max": 32.1, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010216", "000019", "0", "2012/Mar/27 10:12", "Halstead Boilers", "Halstead", "Eden VBX 30", "", "4126017", "2004", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "32.1", "32.1", "", "", "89.8", "80.8", "", "59.0", "", "2", "1", "", "102", "1", "2", "110", "5", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.3", "100.8", "", "", "", "", "98.8"]} +{"pcdb_id": 10217, "brand_name": "Viessmann", "model_name": "Vitodens 200", "model_qualifier": "WB2A", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 24.7, "final_year_of_manufacture": 2007, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010217", "000033", "0", "2012/Dec/06 13:18", "Viessmann", "Viessmann", "Vitodens 200", "WB2A", "", "2004", "2007", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24.7", "24.7", "", "", "88.5", "79.5", "", "58.1", "", "2", "", "", "102", "1", "2", "120", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "98.1", "", "", "", "", "96.2"]} +{"pcdb_id": 10218, "brand_name": "Viessmann", "model_name": "Vitodens 200 Combi", "model_qualifier": "WB2A", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 56.2, "output_kw_max": 24.7, "final_year_of_manufacture": 2007, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010218", "000033", "0", "2009/Jan/27 08:30", "Viessmann", "Viessmann", "Vitodens 200 Combi", "WB2A", "", "2004", "2007", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.7", "24.7", "", "", "88.5", "79.9", "", "56.2", "", "2", "", "", "104", "1", "2", "120", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "98.1", "", "", "", "", "96.2"]} +{"pcdb_id": 10219, "brand_name": "Sile SpA", "model_name": "Condensa 32 NN", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 30.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010219", "000221", "0", "2012/Mar/27 10:12", "Sile SpA", "Sile SpA", "Condensa 32 NN", "", "", "2004", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "30.0", "30.0", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "175", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.2", "97.8", "", "", "", "", "96.0"]} +{"pcdb_id": 10221, "brand_name": "Radiant", "model_name": "Radiant", "model_qualifier": "RK 50", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 54.47, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010221", "000088", "0", "2012/Mar/27 10:12", "Radiant Bruciatori SpA", "Radiant", "Radiant", "RK 50", "", "2004", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "54.47", "54.47", "", "", "88.2", "79.2", "", "57.8", "", "2", "", "", "102", "1", "2", "195", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.1", "97.2", "", "", "", "", "95.5"]} +{"pcdb_id": 10222, "brand_name": "Saunier Duval", "model_name": "Isofast Condens F35e", "model_qualifier": "", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 56.0, "output_kw_max": 28.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010222", "000206", "0", "2009/Mar/31 14:33", "Hepworth Heating", "Saunier Duval", "Isofast Condens F35e", "", "GC 47-920-46", "2004", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28.00", "28.00", "", "", "88.2", "79.6", "", "56.0", "", "2", "", "", "104", "1", "2", "206", "30", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "2", "0", "30", "0005", "", "", "", "", "", "", "", "", "88.1", "97.3", "", "", "", "", "95.6"]} +{"pcdb_id": 10224, "brand_name": "Baxi", "model_name": "Bermuda", "model_qualifier": "50/6 Inset", "winter_efficiency_pct": 79.1, "summer_efficiency_pct": 68.4, "comparative_hot_water_efficiency_pct": 50.0, "output_kw_max": 14.65, "final_year_of_manufacture": 2010, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010224", "000005", "0", "2012/Mar/27 10:12", "Baxi Potterton", "Baxi", "Bermuda", "50/6 Inset", "GC No. 44-075-08", "2004", "2010", "1", "4", "1", "1", "0", "", "", "1", "1", "1", "14.65", "14.65", "", "", "79.1", "68.4", "", "50.0", "", "2", "", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.6", "78.6", "", "", "", "", "79.1"]} +{"pcdb_id": 10225, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "12 Ri", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 12.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010225", "000035", "0", "2020/Sep/08 09:19", "Worcester Heat Systems", "Worcester", "Greenstar", "12 Ri", "41-311-64", "2004", "2015", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "12.0", "12.0", "", "", "89.1", "80.1", "", "58.5", "", "2", "1", "", "102", "1", "2", "50", "5", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.7", "99.2", "", "", "", "", "97.4"]} +{"pcdb_id": 10226, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "24 Ri", "winter_efficiency_pct": 89.5, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 58.8, "output_kw_max": 24.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010226", "000035", "0", "2020/Sep/04 09:25", "Worcester Heat Systems", "Worcester", "Greenstar", "24 Ri", "41-311-66", "2004", "2015", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "24.0", "24.0", "", "", "89.5", "80.5", "", "58.8", "", "2", "1", "", "102", "1", "2", "50", "5", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.0", "100.1", "", "", "", "", "98.2"]} +{"pcdb_id": 10227, "brand_name": "Ariston", "model_name": "ACO 27 RFFI", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 22.5, "final_year_of_manufacture": 2007, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010227", "000080", "0", "2012/Mar/27 10:12", "Merloni TermoSanitari SpA", "Ariston", "ACO 27 RFFI", "", "GC No 41-116-09", "2004", "2007", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "22.5", "22.5", "", "", "88.1", "79.1", "", "57.8", "", "2", "", "", "102", "1", "2", "118", "5", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.6", "96.9", "", "", "", "", "95.3"]} +{"pcdb_id": 10228, "brand_name": "Ariston", "model_name": "ACO 32 RFFI", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 28.0, "final_year_of_manufacture": 2007, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010228", "000080", "0", "2012/Mar/27 10:12", "Merloni TermoSanitari SpA", "Ariston", "ACO 32 RFFI", "", "GC No 41-116-10", "2004", "2007", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "28", "28", "", "", "88.3", "79.3", "", "57.9", "", "2", "", "", "102", "1", "2", "118", "5", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.7", "97.2", "", "", "", "", "95.6"]} +{"pcdb_id": 10229, "brand_name": "Ariston", "model_name": "ACO 32 MFFI", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 56.0, "output_kw_max": 28.0, "final_year_of_manufacture": 2007, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010229", "000080", "0", "2008/Jun/26 09:07", "Merloni TermoSanitari SpA", "Ariston", "ACO 32 MFFI", "", "GC No 47-116-35", "2004", "2007", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28", "28", "", "", "88.3", "79.7", "", "56.0", "", "2", "", "", "104", "1", "2", "118", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.7", "97.2", "", "", "", "", "95.6"]} +{"pcdb_id": 10230, "brand_name": "Baxi", "model_name": "50 HE Plus", "model_qualifier": "", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 15.24, "final_year_of_manufacture": 2006, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010230", "000005", "0", "2012/Mar/27 10:12", "Baxi Potterton", "Baxi", "50 HE Plus", "", "GC No. 41-077-41", "2004", "2006", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "15.24", "15.24", "", "", "88.7", "79.7", "", "58.2", "", "2", "", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.3", "97.7", "", "", "", "", "96.3"]} +{"pcdb_id": 10231, "brand_name": "Baxi", "model_name": "80 HE Plus", "model_qualifier": "", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 22.0, "final_year_of_manufacture": 2006, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010231", "000005", "0", "2012/Mar/27 10:12", "Baxi Potterton", "Baxi", "80 HE Plus", "", "GC No. 41-077-42", "2004", "2006", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "22.0", "22.0", "", "", "88.9", "79.9", "", "58.4", "", "2", "", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.5", "98.5", "", "", "", "", "96.8"]} +{"pcdb_id": 10232, "brand_name": "Ideal", "model_name": "mini", "model_qualifier": "HE C28", "winter_efficiency_pct": 85.9, "summer_efficiency_pct": 77.3, "comparative_hot_water_efficiency_pct": 54.4, "output_kw_max": 28.3, "final_year_of_manufacture": 2011, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010232", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "mini", "HE C28", "47-348-39", "2004", "2011", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28.3", "28.3", "", "", "85.9", "77.3", "", "54.4", "", "2", "", "", "104", "1", "2", "150", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "91.5", "", "", "", "", "90.8"]} +{"pcdb_id": 10233, "brand_name": "Ideal", "model_name": "mini", "model_qualifier": "HE C24", "winter_efficiency_pct": 85.8, "summer_efficiency_pct": 77.2, "comparative_hot_water_efficiency_pct": 54.3, "output_kw_max": 24.6, "final_year_of_manufacture": 2011, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010233", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "mini", "HE C24", "47-348-38", "2004", "2011", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.6", "24.6", "", "", "85.8", "77.2", "", "54.3", "", "2", "", "", "104", "1", "2", "140", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.7", "90.9", "", "", "", "", "90.5"]} +{"pcdb_id": 10234, "brand_name": "Ideal", "model_name": "excel", "model_qualifier": "HE C24", "winter_efficiency_pct": 85.3, "summer_efficiency_pct": 76.7, "comparative_hot_water_efficiency_pct": 54.0, "output_kw_max": 23.4, "final_year_of_manufacture": 2009, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010234", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "excel", "HE C24", "47-348-35", "2004", "2009", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "23.4", "23.4", "", "", "85.3", "76.7", "", "54.0", "", "2", "", "", "104", "1", "2", "168", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "86.3", "90.7", "", "", "", "", "89.9"]} +{"pcdb_id": 10235, "brand_name": "Ideal", "model_name": "excel", "model_qualifier": "HE C28", "winter_efficiency_pct": 85.3, "summer_efficiency_pct": 76.7, "comparative_hot_water_efficiency_pct": 53.9, "output_kw_max": 28.0, "final_year_of_manufacture": 2009, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010235", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "excel", "HE C28", "47-348-36", "2004", "2009", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28.0", "28.0", "", "", "85.3", "76.7", "", "53.9", "", "2", "", "", "104", "1", "2", "180", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "85.5", "91.5", "", "", "", "", "90.3"]} +{"pcdb_id": 10236, "brand_name": "Ideal", "model_name": "excel", "model_qualifier": "HE C32", "winter_efficiency_pct": 85.3, "summer_efficiency_pct": 76.7, "comparative_hot_water_efficiency_pct": 53.9, "output_kw_max": 32.0, "final_year_of_manufacture": 2009, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010236", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "excel", "HE C32", "47-348-37", "2004", "2009", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "32.0", "32.0", "", "", "85.3", "76.7", "", "53.9", "", "2", "", "", "104", "1", "2", "184", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "86.0", "90.8", "", "", "", "", "89.9"]} +{"pcdb_id": 10237, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "30 Si", "winter_efficiency_pct": 89.5, "summer_efficiency_pct": 80.9, "comparative_hot_water_efficiency_pct": 63.1, "output_kw_max": 24.0, "final_year_of_manufacture": 2013, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010237", "000035", "0", "2020/Sep/04 09:25", "Worcester Heat Systems", "Worcester", "Greenstar", "30 Si", "47-311-89", "2005", "2013", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "89.5", "80.9", "", "63.1", "", "2", "1", "", "104", "1", "2", "140", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "", "0305", "", "", "", "", "", "", "", "", "90.0", "100.1", "", "", "", "", "98.2"]} +{"pcdb_id": 10238, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "25 Si", "winter_efficiency_pct": 89.5, "summer_efficiency_pct": 80.9, "comparative_hot_water_efficiency_pct": 63.1, "output_kw_max": 24.0, "final_year_of_manufacture": 2013, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010238", "000035", "0", "2020/Sep/04 09:26", "Worcester Heat Systems", "Worcester", "Greenstar", "25 Si", "47-311-88", "2005", "2013", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "89.5", "80.9", "", "63.1", "", "2", "1", "", "104", "1", "2", "140", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "", "0305", "", "", "", "", "", "", "", "", "90.0", "100.1", "", "", "", "", "98.2"]} +{"pcdb_id": 10239, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "24i junior", "winter_efficiency_pct": 89.5, "summer_efficiency_pct": 90.3, "comparative_hot_water_efficiency_pct": 69.9, "output_kw_max": 24.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.0008, "loss_factor_f1_kwh_per_day": 1.55951, "loss_factor_f2_kwh_per_day": 1.54914, "rejected_factor_f3_per_litre": 0.0, "raw": ["010239", "000035", "0", "2020/Sep/04 10:30", "Worcester Heat Systems", "Worcester", "Greenstar", "24i junior", "", "2005", "2015", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "89.5", "90.3", "", "69.9", "", "2", "1", "", "104", "1", "2", "140", "3.5", "0", "", "", "0", "0", "", "", "", "", "2", "7.7", "0.133", "0.0008", "1.55951", "13.48", "0.166", "0.0004", "1.54914", "0.0", "1", "1", "", "0305", "", "", "", "", "", "", "", "", "90.0", "100.1", "", "", "", "", "98.2"]} +{"pcdb_id": 10240, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "28i junior", "winter_efficiency_pct": 89.5, "summer_efficiency_pct": 90.3, "comparative_hot_water_efficiency_pct": 70.2, "output_kw_max": 24.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.0008, "loss_factor_f1_kwh_per_day": 1.53064, "loss_factor_f2_kwh_per_day": 1.52031, "rejected_factor_f3_per_litre": 0.0, "raw": ["010240", "000035", "0", "2020/Sep/04 10:30", "Worcester Heat Systems", "Worcester", "Greenstar", "28i junior", "", "2005", "2015", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "89.5", "90.3", "", "70.2", "", "2", "1", "", "104", "1", "2", "140", "3.5", "0", "", "", "0", "0", "", "", "", "", "2", "7.67", "0.132", "0.0008", "1.53064", "13.58", "0.167", "0.0004", "1.52031", "0.0", "1", "1", "", "0305", "", "", "", "", "", "", "", "", "90.0", "100.1", "", "", "", "", "98.2"]} +{"pcdb_id": 10241, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "30 Si", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 86.7, "comparative_hot_water_efficiency_pct": 64.6, "output_kw_max": 24.0, "final_year_of_manufacture": 2013, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0106, "loss_factor_f1_kwh_per_day": 1.93522, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010241", "000035", "0", "2020/Sep/04 10:30", "Worcester Heat Systems", "Worcester", "Greenstar", "30 Si", "47-311-85", "2005", "2013", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "88.5", "86.7", "", "64.6", "", "2", "", "", "104", "1", "2", "140", "5", "0", "", "", "0", "0", "", "", "", "", "1", "8.15", "0.27", "0.0106", "1.93522", "", "", "", "", "", "1", "1", "", "0305", "", "", "", "", "", "", "", "", "88.0", "97.9", "", "", "", "", "96.1"]} +{"pcdb_id": 10242, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "25 Si", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 86.7, "comparative_hot_water_efficiency_pct": 65.8, "output_kw_max": 24.0, "final_year_of_manufacture": 2013, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0104, "loss_factor_f1_kwh_per_day": 1.79206, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010242", "000035", "0", "2020/Sep/04 10:30", "Worcester Heat Systems", "Worcester", "Greenstar", "25 Si", "47-311-84", "2005", "2013", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "88.5", "86.7", "", "65.8", "", "2", "", "", "104", "1", "2", "140", "5", "0", "", "", "0", "0", "", "", "", "", "1", "8.0", "0.26", "0.0104", "1.79206", "", "", "", "", "", "1", "1", "", "0305", "", "", "", "", "", "", "", "", "88.0", "97.9", "", "", "", "", "96.1"]} +{"pcdb_id": 10243, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "24i junior", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 88.2, "comparative_hot_water_efficiency_pct": 67.7, "output_kw_max": 24.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.0024, "loss_factor_f1_kwh_per_day": 1.62713, "loss_factor_f2_kwh_per_day": 1.60488, "rejected_factor_f3_per_litre": 2e-05, "raw": ["010243", "000035", "0", "2020/Sep/04 10:31", "Worcester Heat Systems", "Worcester", "Greenstar", "24i junior", "", "2005", "2015", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "88.5", "88.2", "", "67.7", "", "2", "", "", "104", "1", "2", "140", "3.5", "0", "", "", "0", "0", "", "", "", "", "2", "7.78", "0.128", "0.0024", "1.62713", "13.35", "0.163", "0.0009", "1.60488", "0.00002", "1", "1", "", "0305", "", "", "", "", "", "", "", "", "88.0", "97.9", "", "", "", "", "96.1"]} +{"pcdb_id": 10244, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "28i junior", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 88.2, "comparative_hot_water_efficiency_pct": 67.5, "output_kw_max": 24.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.0018, "loss_factor_f1_kwh_per_day": 1.64959, "loss_factor_f2_kwh_per_day": 1.62728, "rejected_factor_f3_per_litre": 1e-05, "raw": ["010244", "000035", "0", "2020/Sep/04 10:31", "Worcester Heat Systems", "Worcester", "Greenstar", "28i junior", "", "2005", "2015", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "88.5", "88.2", "", "67.5", "", "2", "", "", "104", "1", "2", "140", "3.5", "0", "", "", "0", "0", "", "", "", "", "2", "7.8", "0.134", "0.0018", "1.64959", "13.59", "0.162", "0.0009", "1.62728", "0.00001", "1", "1", "", "0305", "", "", "", "", "", "", "", "", "88.0", "97.9", "", "", "", "", "96.1"]} +{"pcdb_id": 10245, "brand_name": "Vaillant", "model_name": "Ecomax", "model_qualifier": "635 E", "winter_efficiency_pct": 89.5, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 58.8, "output_kw_max": 34.9, "final_year_of_manufacture": 2010, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010245", "000031", "0", "2012/Mar/27 10:12", "Vaillant", "Vaillant", "Ecomax", "635 E", "VU GB 356-C", "2004", "2010", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "34.9", "34.9", "", "", "89.5", "80.5", "", "58.8", "", "2", "1", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "92.0", "99.3", "", "", "", "", "97.9"]} +{"pcdb_id": 10246, "brand_name": "DD Heating", "model_name": "Heatline", "model_qualifier": "Solaris 30 PC", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 55.9, "output_kw_max": 29.8, "final_year_of_manufacture": 2009, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010246", "000215", "0", "2011/Aug/31 10:34", "Turk Demir Dokum Fab AS", "DD Heating", "Heatline", "Solaris 30 PC", "", "2004", "2009", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "29.8", "29.8", "", "", "88.0", "79.4", "", "55.9", "", "2", "", "", "104", "1", "2", "140", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.1", "96.9", "", "", "", "", "95.2"]} +{"pcdb_id": 10247, "brand_name": "DD Heating", "model_name": "Heatline", "model_qualifier": "Solaris 30PCS", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 29.8, "final_year_of_manufacture": 2009, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010247", "000215", "0", "2012/Mar/27 10:12", "Turk Demir Dokum Fab AS", "DD Heating", "Heatline", "Solaris 30PCS", "", "2004", "2009", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "29.8", "29.8", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "140", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.1", "96.9", "", "", "", "", "95.2"]} +{"pcdb_id": 10248, "brand_name": "DD Heating", "model_name": "Heatline", "model_qualifier": "C28", "winter_efficiency_pct": 85.5, "summer_efficiency_pct": 76.9, "comparative_hot_water_efficiency_pct": 54.1, "output_kw_max": 27.47, "final_year_of_manufacture": 2007, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010248", "000215", "0", "2011/Aug/31 10:41", "Turk Demir Dokum Fab AS", "DD Heating", "Heatline", "C28", "", "2004", "2007", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "27.47", "27.47", "", "", "85.5", "76.9", "", "54.1", "", "2", "", "", "104", "1", "2", "196", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "86.9", "91.0", "", "", "", "", "90.2"]} +{"pcdb_id": 10249, "brand_name": "DD Heating", "model_name": "Heatline", "model_qualifier": "C28S", "winter_efficiency_pct": 85.5, "summer_efficiency_pct": 76.9, "comparative_hot_water_efficiency_pct": 54.1, "output_kw_max": 27.47, "final_year_of_manufacture": 2007, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010249", "000215", "0", "2011/Aug/31 10:40", "Turk Demir Dokum Fab AS", "DD Heating", "Heatline", "C28S", "", "2004", "2007", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "27.47", "27.47", "", "", "85.5", "76.9", "", "54.1", "", "2", "", "", "104", "1", "2", "196", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "86.9", "91.0", "", "", "", "", "90.2"]} +{"pcdb_id": 10251, "brand_name": "Geminox", "model_name": "THI 5-25 C DC", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 23.9, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010251", "000212", "0", "2012/Mar/27 10:12", "Geminox", "Geminox", "THI 5-25 C DC", "", "", "2004", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "23.9", "23.9", "", "", "88.3", "79.3", "", "58.0", "", "2", "", "", "102", "1", "2", "65", "9.2", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "97.8", "", "", "", "", "95.9"]} +{"pcdb_id": 10252, "brand_name": "Geminox", "model_name": "Astrane 30S FIOUL", "model_qualifier": "", "winter_efficiency_pct": 85.2, "summer_efficiency_pct": 73.5, "comparative_hot_water_efficiency_pct": 53.7, "output_kw_max": 28.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010252", "000212", "0", "2012/Mar/27 10:12", "Geminox", "Geminox", "Astrane 30S FIOUL", "", "", "2003", "current", "4", "1", "1", "1", "0", "", "", "1", "3", "2", "28.2", "28.2", "", "", "85.2", "73.5", "", "53.7", "", "2", "", "", "201", "1", "1", "269", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.5", "84.9", "", "", "", "", "85.0"]} +{"pcdb_id": 10253, "brand_name": "Atmos", "model_name": "InterCombi", "model_qualifier": "HE32", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 62.2, "output_kw_max": 15.7, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010253", "000141", "0", "2007/Apr/30 11:46", "Intergas Verwarming", "Atmos", "InterCombi", "HE32", "", "2004", "current", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "15.7", "15.7", "", "", "88.3", "79.7", "", "62.2", "", "2", "", "", "104", "1", "2", "40", "2.4", "0", "", "", "1", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "", "0005", "", "", "", "", "", "", "", "", "88.1", "97.5", "", "", "", "", "95.7"]} +{"pcdb_id": 10255, "brand_name": "Viessmann", "model_name": "Vitodens 333", "model_qualifier": "WS3A", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 56.4, "output_kw_max": 23.7, "final_year_of_manufacture": 2007, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010255", "000033", "0", "2006/Jan/17 12:31", "Viessmann", "Viessmann", "Vitodens 333", "WS3A", "", "2004", "2007", "1", "1", "1", "2", "0", "", "", "2", "2", "2", "23.7", "23.7", "", "", "88.7", "80.1", "", "56.4", "", "2", "", "", "104", "1", "2", "130", "11", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "98.7", "", "", "", "", "96.6"]} +{"pcdb_id": 10256, "brand_name": "Viessmann", "model_name": "Vitodens 300 Combi", "model_qualifier": "WB3A - 24kW", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 56.4, "output_kw_max": 23.7, "final_year_of_manufacture": 2007, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010256", "000033", "0", "2006/Jan/17 12:31", "Viessmann", "Viessmann", "Vitodens 300 Combi", "WB3A - 24kW", "", "2004", "2007", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "23.7", "23.7", "", "", "88.7", "80.1", "", "56.4", "", "2", "", "", "104", "1", "2", "130", "11", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "98.7", "", "", "", "", "96.6"]} +{"pcdb_id": 10257, "brand_name": "Viessmann", "model_name": "Vitodens 300", "model_qualifier": "WB3A - 24kW", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 23.7, "final_year_of_manufacture": 2007, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010257", "000033", "0", "2012/Mar/27 10:12", "Viessmann", "Viessmann", "Vitodens 300", "WB3A - 24kW", "", "2004", "2007", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "23.7", "23.7", "", "", "88.7", "79.7", "", "58.2", "", "2", "", "", "102", "1", "2", "130", "11", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "98.7", "", "", "", "", "96.6"]} +{"pcdb_id": 10258, "brand_name": "Viessmann", "model_name": "Vitodens 300", "model_qualifier": "WB3A - 32kW", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 32.0, "final_year_of_manufacture": 2007, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010258", "000033", "0", "2012/Mar/27 10:12", "Viessmann", "Viessmann", "Vitodens 300", "WB3A - 32kW", "", "2004", "2007", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "32", "32", "", "", "88.7", "79.7", "", "58.2", "", "2", "", "", "102", "1", "2", "148", "11", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "98.5", "", "", "", "", "96.5"]} +{"pcdb_id": 10259, "brand_name": "Viessmann", "model_name": "Vitodens 300", "model_qualifier": "WB3A - 44kW", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 44.6, "final_year_of_manufacture": 2007, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010259", "000033", "0", "2012/Mar/27 10:12", "Viessmann", "Viessmann", "Vitodens 300", "WB3A - 44kW", "", "2004", "2007", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "44.6", "44.6", "", "", "88.5", "79.5", "", "58.1", "", "2", "", "", "102", "1", "2", "72", "11", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "98.0", "", "", "", "", "96.1"]} +{"pcdb_id": 10260, "brand_name": "Viessmann", "model_name": "Vitodens 300", "model_qualifier": "WB3A - 66kW", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 60.1, "final_year_of_manufacture": 2007, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010260", "000033", "0", "2012/Mar/27 10:12", "Viessmann", "Viessmann", "Vitodens 300", "WB3A - 66kW", "", "2004", "2007", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "60.1", "60.1", "", "", "88.5", "79.5", "", "58.1", "", "2", "", "", "102", "1", "2", "104", "11", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "98.2", "", "", "", "", "96.2"]} +{"pcdb_id": 10261, "brand_name": "Potterton", "model_name": "Promax", "model_qualifier": "15/2 HE Plus", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 15.24, "final_year_of_manufacture": 2010, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010261", "000005", "0", "2012/Mar/27 10:12", "Baxi Potterton", "Potterton", "Promax", "15/2 HE Plus", "GC No. 41-605-52", "2005", "2010", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "15.24", "15.24", "", "", "88.7", "79.7", "", "58.2", "", "2", "", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.3", "97.7", "", "", "", "", "96.3"]} +{"pcdb_id": 10262, "brand_name": "Potterton", "model_name": "Promax", "model_qualifier": "24/2 HE Plus", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 22.0, "final_year_of_manufacture": 2010, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010262", "000005", "0", "2012/Mar/27 10:12", "Baxi Potterton", "Potterton", "Promax", "24/2 HE Plus", "GC No. 41-601-17", "2005", "2010", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "22.0", "22.0", "", "", "88.9", "79.9", "", "58.4", "", "2", "", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.5", "98.5", "", "", "", "", "96.8"]} +{"pcdb_id": 10263, "brand_name": "Worcester", "model_name": "Greenstar CDi", "model_qualifier": "25 Cdi", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 56.8, "output_kw_max": 25.0, "final_year_of_manufacture": 2007, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010263", "000035", "0", "2020/Sep/04 10:31", "Worcester Heat Systems", "Worcester", "Greenstar CDi", "25 Cdi", "47-311-92", "2005", "2007", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "25", "25", "", "", "89.4", "80.8", "", "56.8", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0305", "", "", "", "", "", "", "", "", "88.5", "100.3", "", "", "", "", "98.0"]} +{"pcdb_id": 10264, "brand_name": "Worcester", "model_name": "Greenstar CDi", "model_qualifier": "25 Cdi", "winter_efficiency_pct": 90.5, "summer_efficiency_pct": 81.9, "comparative_hot_water_efficiency_pct": 57.6, "output_kw_max": 25.0, "final_year_of_manufacture": 2007, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010264", "000035", "0", "2020/Sep/04 10:32", "Worcester Heat Systems", "Worcester", "Greenstar CDi", "25 Cdi", "", "2005", "2007", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "25", "25", "", "", "90.5", "81.9", "", "57.6", "", "2", "1", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0305", "", "", "", "", "", "", "", "", "90.4", "102.5", "", "", "", "", "100.2"]} +{"pcdb_id": 10265, "brand_name": "Worcester", "model_name": "Greenstar CDi", "model_qualifier": "30 CDi", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 56.4, "output_kw_max": 30.0, "final_year_of_manufacture": 2007, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010265", "000035", "0", "2020/Sep/08 09:20", "Worcester Heat Systems", "Worcester", "Greenstar CDi", "30 CDi", "47-311-93", "2005", "2007", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "30", "30", "", "", "88.8", "80.2", "", "56.4", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0305", "", "", "", "", "", "", "", "", "88.1", "98.8", "", "", "", "", "96.8"]} +{"pcdb_id": 10266, "brand_name": "Worcester", "model_name": "Greenstar CDi", "model_qualifier": "30 Cdi", "winter_efficiency_pct": 89.8, "summer_efficiency_pct": 81.2, "comparative_hot_water_efficiency_pct": 57.1, "output_kw_max": 30.0, "final_year_of_manufacture": 2007, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010266", "000035", "0", "2020/Sep/08 09:22", "Worcester Heat Systems", "Worcester", "Greenstar CDi", "30 Cdi", "", "2005", "2007", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "30", "30", "", "", "89.8", "81.2", "", "57.1", "", "2", "1", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0305", "", "", "", "", "", "", "", "", "90.1", "101.0", "", "", "", "", "99.0"]} +{"pcdb_id": 10267, "brand_name": "Worcester", "model_name": "Greenstar CDi", "model_qualifier": "35 CDi", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 56.4, "output_kw_max": 30.0, "final_year_of_manufacture": 2007, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010267", "000035", "0", "2020/Sep/08 09:22", "Worcester Heat Systems", "Worcester", "Greenstar CDi", "35 CDi", "47-311-94", "2005", "2007", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "30", "30", "", "", "88.8", "80.2", "", "56.4", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0305", "", "", "", "", "", "", "", "", "88.1", "98.8", "", "", "", "", "96.8"]} +{"pcdb_id": 10268, "brand_name": "Worcester", "model_name": "Greenstar CDi", "model_qualifier": "35 Cdi", "winter_efficiency_pct": 89.8, "summer_efficiency_pct": 81.2, "comparative_hot_water_efficiency_pct": 57.1, "output_kw_max": 30.0, "final_year_of_manufacture": 2007, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010268", "000035", "0", "2020/Sep/08 09:22", "Worcester Heat Systems", "Worcester", "Greenstar CDi", "35 Cdi", "", "2005", "2007", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "30", "30", "", "", "89.8", "81.2", "", "57.1", "", "2", "1", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0305", "", "", "", "", "", "", "", "", "90.1", "101.0", "", "", "", "", "99.0"]} +{"pcdb_id": 10269, "brand_name": "Ariston", "model_name": "Microgenus 24 HE MFFI", "model_qualifier": "", "winter_efficiency_pct": 86.0, "summer_efficiency_pct": 77.4, "comparative_hot_water_efficiency_pct": 54.4, "output_kw_max": 23.3, "final_year_of_manufacture": 2008, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010269", "000080", "0", "2009/Jul/28 09:49", "Merloni TermoSanitari SpA", "Ariston", "Microgenus 24 HE MFFI", "", "GC No. 47-116-37", "2004", "2008", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "23.3", "23.3", "", "", "86.0", "77.4", "", "54.4", "", "2", "", "", "104", "1", "2", "148", "7", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.5", "91.9", "", "", "", "", "91.1"]} +{"pcdb_id": 10270, "brand_name": "Ariston", "model_name": "Microgenus 28 HE MFFI", "model_qualifier": "", "winter_efficiency_pct": 85.7, "summer_efficiency_pct": 77.1, "comparative_hot_water_efficiency_pct": 54.2, "output_kw_max": 27.0, "final_year_of_manufacture": 2008, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010270", "000080", "0", "2009/Jul/28 09:46", "Merloni TermoSanitari SpA", "Ariston", "Microgenus 28 HE MFFI", "", "GC No. 47-116-39", "2004", "2008", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "27.0", "27.0", "", "", "85.7", "77.1", "", "54.2", "", "2", "", "", "104", "1", "2", "148", "7", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "86.8", "91.5", "", "", "", "", "90.6"]} +{"pcdb_id": 10271, "brand_name": "Ariston", "model_name": "Microgenus 32 HE MFFI", "model_qualifier": "", "winter_efficiency_pct": 85.9, "summer_efficiency_pct": 77.3, "comparative_hot_water_efficiency_pct": 54.3, "output_kw_max": 30.5, "final_year_of_manufacture": 2008, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010271", "000080", "0", "2009/Jul/28 09:48", "Merloni TermoSanitari SpA", "Ariston", "Microgenus 32 HE MFFI", "", "GC No. 47-116-38", "2004", "2008", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "30.5", "30.5", "", "", "85.9", "77.3", "", "54.3", "", "2", "", "", "104", "1", "2", "148", "7", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.1", "91.7", "", "", "", "", "90.8"]} +{"pcdb_id": 10272, "brand_name": "Radiant", "model_name": "B-condense", "model_qualifier": "RHR 28", "winter_efficiency_pct": 85.2, "summer_efficiency_pct": 76.6, "comparative_hot_water_efficiency_pct": 53.9, "output_kw_max": 27.47, "final_year_of_manufacture": 2007, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010272", "000088", "0", "2007/Sep/03 13:03", "Radiant Bruciatori SpA", "Radiant", "B-condense", "RHR 28", "", "2005", "2007", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "27.47", "27.47", "", "", "85.2", "76.6", "", "53.9", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "85.8", "90.8", "", "", "", "", "89.9"]} +{"pcdb_id": 10273, "brand_name": "Radiant", "model_name": "B-condense", "model_qualifier": "RH 28", "winter_efficiency_pct": 85.2, "summer_efficiency_pct": 76.2, "comparative_hot_water_efficiency_pct": 55.7, "output_kw_max": 27.47, "final_year_of_manufacture": 2007, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010273", "000088", "0", "2012/Mar/27 10:12", "Radiant Bruciatori SpA", "Radiant", "B-condense", "RH 28", "", "2005", "2007", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "27.47", "27.47", "", "", "85.2", "76.2", "", "55.7", "", "2", "", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "85.8", "90.8", "", "", "", "", "89.9"]} +{"pcdb_id": 10274, "brand_name": "Ferroli", "model_name": "Optimax", "model_qualifier": "25 C LPG", "winter_efficiency_pct": 89.7, "summer_efficiency_pct": 81.1, "comparative_hot_water_efficiency_pct": 57.1, "output_kw_max": 24.7, "final_year_of_manufacture": 2008, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010274", "000097", "0", "2009/Apr/28 16:11", "Ferroli SpA", "Ferroli", "Optimax", "25 C LPG", "", "2004", "2008", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24.7", "24.7", "", "", "89.7", "81.1", "", "57.1", "", "2", "1", "", "104", "1", "2", "140", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "", "", "0005", "", "", "", "", "", "", "", "", "90.4", "100.7", "", "", "", "", "98.7"]} +{"pcdb_id": 10275, "brand_name": "Ferroli", "model_name": "Optimax", "model_qualifier": "25 S LPG", "winter_efficiency_pct": 89.7, "summer_efficiency_pct": 80.7, "comparative_hot_water_efficiency_pct": 59.0, "output_kw_max": 25.0, "final_year_of_manufacture": 2008, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010275", "000097", "0", "2012/Mar/27 10:12", "Ferroli SpA", "Ferroli", "Optimax", "25 S LPG", "", "2004", "2008", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "25.0", "25.0", "", "", "89.7", "80.7", "", "59.0", "", "2", "1", "", "102", "1", "2", "130", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.4", "100.7", "", "", "", "", "98.7"]} +{"pcdb_id": 10276, "brand_name": "Ferroli", "model_name": "Optimax", "model_qualifier": "25 OV LPG", "winter_efficiency_pct": 89.7, "summer_efficiency_pct": 80.7, "comparative_hot_water_efficiency_pct": 59.0, "output_kw_max": 24.7, "final_year_of_manufacture": 2008, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010276", "000097", "0", "2012/Mar/27 10:12", "Ferroli SpA", "Ferroli", "Optimax", "25 OV LPG", "", "2004", "2008", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "24.7", "24.7", "", "", "89.7", "80.7", "", "59.0", "", "2", "1", "", "102", "1", "2", "60", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.4", "100.7", "", "", "", "", "98.7"]} +{"pcdb_id": 10277, "brand_name": "Ferroli", "model_name": "Maxima", "model_qualifier": "35 C LPG", "winter_efficiency_pct": 89.9, "summer_efficiency_pct": 81.3, "comparative_hot_water_efficiency_pct": 57.2, "output_kw_max": 34.1, "final_year_of_manufacture": 2008, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010277", "000097", "0", "2009/Apr/28 16:00", "Ferroli SpA", "Ferroli", "Maxima", "35 C LPG", "", "2004", "2008", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "34.1", "34.1", "", "", "89.9", "81.3", "", "57.2", "", "2", "1", "", "104", "1", "2", "150", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "", "", "0005", "", "", "", "", "", "", "", "", "91.6", "100.5", "", "", "", "", "98.8"]} +{"pcdb_id": 10278, "brand_name": "Ferroli", "model_name": "Maxima", "model_qualifier": "35 S LPG", "winter_efficiency_pct": 89.9, "summer_efficiency_pct": 80.9, "comparative_hot_water_efficiency_pct": 59.1, "output_kw_max": 34.6, "final_year_of_manufacture": 2008, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010278", "000097", "0", "2012/Mar/27 10:12", "Ferroli SpA", "Ferroli", "Maxima", "35 S LPG", "", "2004", "2008", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "34.6", "34.6", "", "", "89.9", "80.9", "", "59.1", "", "2", "1", "", "102", "1", "2", "150", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "91.6", "100.5", "", "", "", "", "98.8"]} +{"pcdb_id": 10279, "brand_name": "Ferroli", "model_name": "Econcept", "model_qualifier": "50 A LPG", "winter_efficiency_pct": 89.6, "summer_efficiency_pct": 80.6, "comparative_hot_water_efficiency_pct": 58.9, "output_kw_max": 45.2, "final_year_of_manufacture": 2017, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010279", "000097", "0", "2017/Aug/21 13:42", "Ferroli SpA", "Ferroli", "Econcept", "50 A LPG", "", "2002", "2017", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "45.2", "45.2", "", "", "89.6", "80.6", "", "58.9", "", "2", "1", "", "102", "1", "2", "190", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.4", "100.4", "", "", "", "", "98.5"]} +{"pcdb_id": 10281, "brand_name": "MHS Boilers", "model_name": "Ultramax WM", "model_qualifier": "65", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 59.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010281", "000024", "0", "2012/Mar/27 10:12", "Rendamax", "MHS Boilers", "Ultramax WM", "65", "", "2004", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "59.2", "59.2", "", "", "88.2", "79.2", "", "57.8", "", "2", "", "", "102", "1", "2", "98", "10", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "97.3", "", "", "", "", "95.5"]} +{"pcdb_id": 10286, "brand_name": "MHS Boilers", "model_name": "Ultramax WM", "model_qualifier": "65", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 59.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010286", "000024", "0", "2012/Mar/27 10:12", "Rendamax", "MHS Boilers", "Ultramax WM", "65", "", "2004", "current", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "59.2", "59.2", "", "", "89.2", "80.2", "", "58.6", "", "2", "1", "", "102", "1", "2", "98", "10", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.8", "99.5", "", "", "", "", "97.6"]} +{"pcdb_id": 10291, "brand_name": "Keston", "model_name": "C", "model_qualifier": "36 Combi", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 80.6, "comparative_hot_water_efficiency_pct": 56.7, "output_kw_max": 28.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010291", "000022", "0", "2006/Jan/17 12:31", "Keston Boilers", "Keston", "C", "36 Combi", "47-930-01", "2005", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28.0", "28.0", "", "", "89.2", "80.6", "", "56.7", "", "2", "", "", "104", "1", "2", "180", "6", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "", "", "0005", "", "", "", "", "", "", "", "", "89.2", "99.3", "", "", "", "", "97.4"]} +{"pcdb_id": 10292, "brand_name": "Keston", "model_name": "C", "model_qualifier": "36P Combi", "winter_efficiency_pct": 90.2, "summer_efficiency_pct": 81.6, "comparative_hot_water_efficiency_pct": 57.4, "output_kw_max": 27.7, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010292", "000022", "0", "2006/Jan/17 12:31", "Keston Boilers", "Keston", "C", "36P Combi", "47-930-02", "2005", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "27.7", "27.7", "", "", "90.2", "81.6", "", "57.4", "", "2", "1", "", "104", "1", "2", "180", "6", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "", "", "0005", "", "", "", "", "", "", "", "", "91.2", "101.5", "", "", "", "", "99.5"]} +{"pcdb_id": 10293, "brand_name": "Boulter", "model_name": "Buderus", "model_qualifier": "500-24/C", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.4, "comparative_hot_water_efficiency_pct": 56.5, "output_kw_max": 23.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010293", "000041", "0", "2006/Jan/17 12:31", "Boulter Buderus", "Boulter", "Buderus", "500-24/C", "87470242", "2005", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "23.0", "23.0", "", "", "89.0", "80.4", "", "56.5", "", "2", "", "", "104", "1", "2", "40", "6.5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "99.4", "", "", "", "", "97.2"]} +{"pcdb_id": 10294, "brand_name": "Boulter", "model_name": "Buderus", "model_qualifier": "500-24/CP", "winter_efficiency_pct": 90.0, "summer_efficiency_pct": 81.4, "comparative_hot_water_efficiency_pct": 57.3, "output_kw_max": 23.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010294", "000041", "0", "2006/Jan/17 12:31", "Boulter Buderus", "Boulter", "Buderus", "500-24/CP", "87470222", "2005", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "23.0", "23.0", "", "", "90.0", "81.4", "", "57.3", "", "2", "1", "", "104", "1", "2", "40", "6.5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.8", "101.6", "", "", "", "", "99.3"]} +{"pcdb_id": 10295, "brand_name": "Firebird", "model_name": "Kitchen C20", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 58.8, "output_kw_max": 20.0, "final_year_of_manufacture": 2010, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010295", "000047", "0", "2012/Mar/27 10:12", "Firebird Boilers", "Firebird", "Kitchen C20", "", "", "2005", "2010", "4", "1", "1", "1", "0", "", "", "2", "2", "1", "15", "20", "", "", "88.3", "80.5", "", "58.8", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.7", "95.2", "", "", "", "", "94.5"]} +{"pcdb_id": 10296, "brand_name": "Firebird", "model_name": "Kitchen C26", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 58.8, "output_kw_max": 26.0, "final_year_of_manufacture": 2010, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010296", "000047", "0", "2012/Mar/27 10:12", "Firebird Boilers", "Firebird", "Kitchen C26", "", "", "2005", "2010", "4", "1", "1", "1", "0", "", "", "2", "2", "1", "20", "26", "", "", "88.3", "80.5", "", "58.8", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.5", "95.3", "", "", "", "", "94.6"]} +{"pcdb_id": 10297, "brand_name": "Firebird", "model_name": "Kitchen C35", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 58.7, "output_kw_max": 35.0, "final_year_of_manufacture": 2010, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010297", "000047", "0", "2012/Mar/27 10:12", "Firebird Boilers", "Firebird", "Kitchen C35", "", "", "2005", "2010", "4", "1", "1", "1", "0", "", "", "2", "2", "1", "26", "35", "", "", "88.1", "80.3", "", "58.7", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.4", "94.9", "", "", "", "", "94.2"]} +{"pcdb_id": 10298, "brand_name": "Firebird", "model_name": "Combi C20", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 82.2, "comparative_hot_water_efficiency_pct": 45.0, "output_kw_max": 20.0, "final_year_of_manufacture": 2010, "subsidiary_type": 0, "store_type": 1, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010298", "000047", "0", "2024/Jan/31 10:17", "Firebird Boilers", "Firebird", "Combi C20", "", "", "2005", "2010", "4", "1", "1", "2", "0", "", "", "2", "2", "1", "15", "20", "", "", "88.3", "82.2", "", "45.0", "", "2", "", "", "203", "1", "1", "138", "0", "1", "1", "0", "40", "0", "25", "3", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.7", "95.2", "", "", "", "", "94.5"]} +{"pcdb_id": 10299, "brand_name": "Firebird", "model_name": "Combi C26", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 82.2, "comparative_hot_water_efficiency_pct": 45.0, "output_kw_max": 26.0, "final_year_of_manufacture": 2010, "subsidiary_type": 0, "store_type": 1, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010299", "000047", "0", "2024/Jan/31 10:17", "Firebird Boilers", "Firebird", "Combi C26", "", "", "2005", "2010", "4", "1", "1", "2", "0", "", "", "2", "2", "1", "20", "26", "", "", "88.3", "82.2", "", "45.0", "", "2", "", "", "203", "1", "1", "138", "0", "1", "1", "0", "40", "0", "25", "3", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.5", "95.3", "", "", "", "", "94.6"]} +{"pcdb_id": 10300, "brand_name": "Firebird", "model_name": "Combi C35", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 82.0, "comparative_hot_water_efficiency_pct": 44.9, "output_kw_max": 35.0, "final_year_of_manufacture": 2010, "subsidiary_type": 0, "store_type": 1, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010300", "000047", "0", "2024/Jan/31 10:17", "Firebird Boilers", "Firebird", "Combi C35", "", "", "2005", "2010", "4", "1", "1", "2", "0", "", "", "2", "2", "1", "26", "35", "", "", "88.1", "82.0", "", "44.9", "", "2", "", "", "203", "1", "1", "138", "0", "1", "1", "0", "40", "0", "25", "3", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.4", "94.9", "", "", "", "", "94.2"]} +{"pcdb_id": 10301, "brand_name": "Hermann Srl", "model_name": "Eura Condensing", "model_qualifier": "", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 61.9, "output_kw_max": 27.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010301", "000234", "0", "2013/Jun/25 14:34", "Hermann Srl", "Hermann Srl", "Eura Condensing", "", "CHM573U24", "2003", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "27.6", "27.6", "", "", "87.9", "79.3", "", "61.9", "", "2", "", "", "104", "1", "2", "195", "120", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "", "0005", "", "", "", "", "", "", "", "", "89.0", "96.2", "", "", "", "", "94.9"]} +{"pcdb_id": 10302, "brand_name": "Chaffoteaux et Maury", "model_name": "Minima HE 35", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 56.2, "output_kw_max": 32.0, "final_year_of_manufacture": 2007, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010302", "000010", "0", "2008/Jun/26 09:09", "Chaffoteaux et Maury", "Chaffoteaux et Maury", "Minima HE 35", "", "GC No. 47-980-35", "2004", "2007", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "32", "32", "", "", "88.5", "79.9", "", "56.2", "", "2", "", "", "104", "1", "2", "150", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "98.1", "", "", "", "", "96.2"]} +{"pcdb_id": 10303, "brand_name": "Chaffoteaux et Maury", "model_name": "Minima HE 30", "model_qualifier": "", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 55.9, "output_kw_max": 29.0, "final_year_of_manufacture": 2007, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010303", "000010", "0", "2008/Jun/26 09:09", "Chaffoteaux et Maury", "Chaffoteaux et Maury", "Minima HE 30", "", "GC No. 47-980-34", "2004", "2007", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "29", "29", "", "", "88.2", "79.6", "", "55.9", "", "2", "", "", "104", "1", "2", "150", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.1", "97.1", "", "", "", "", "95.4"]} +{"pcdb_id": 10304, "brand_name": "Chaffoteaux et Maury", "model_name": "Minima HE System 30", "model_qualifier": "", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 29.0, "final_year_of_manufacture": 2007, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010304", "000010", "0", "2012/Mar/27 10:12", "Chaffoteaux et Maury", "Chaffoteaux et Maury", "Minima HE System 30", "", "", "2004", "2007", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "29", "29", "", "", "88.2", "79.2", "", "57.8", "", "2", "", "", "102", "1", "2", "150", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.1", "97.1", "", "", "", "", "95.4"]} +{"pcdb_id": 10305, "brand_name": "Chaffoteaux et Maury", "model_name": "Minima HE System 24", "model_qualifier": "", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 24.0, "final_year_of_manufacture": 2007, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010305", "000010", "0", "2012/Mar/27 10:12", "Chaffoteaux et Maury", "Chaffoteaux et Maury", "Minima HE System 24", "", "", "2004", "2007", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24", "24", "", "", "88.2", "79.2", "", "57.9", "", "2", "", "", "102", "1", "2", "150", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "97.5", "", "", "", "", "95.7"]} +{"pcdb_id": 10306, "brand_name": "Chaffoteaux et Maury", "model_name": "Minima HE 24", "model_qualifier": "", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 56.0, "output_kw_max": 24.0, "final_year_of_manufacture": 2007, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010306", "000010", "0", "2008/Jun/26 09:08", "Chaffoteaux et Maury", "Chaffoteaux et Maury", "Minima HE 24", "", "GC No. 47-980-33", "2004", "2007", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "88.2", "79.6", "", "56.0", "", "2", "", "", "104", "1", "2", "150", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "97.5", "", "", "", "", "95.7"]} +{"pcdb_id": 10307, "brand_name": "Saunier Duval", "model_name": "Xeon 18 HE", "model_qualifier": "", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 78.9, "comparative_hot_water_efficiency_pct": 57.6, "output_kw_max": 18.57, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010307", "000206", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Saunier Duval", "Xeon 18 HE", "", "GC 41-920-38", "2005", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18.57", "18.57", "", "", "87.9", "78.9", "", "57.6", "", "2", "", "", "102", "1", "2", "60", "15", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.6", "96.3", "", "", "", "", "94.8"]} +{"pcdb_id": 10308, "brand_name": "Saunier Duval", "model_name": "Xeon 30 HE", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 28.17, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010308", "000206", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Saunier Duval", "Xeon 30 HE", "", "GC 41-920-46", "2005", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "28.17", "28.17", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "60", "15", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.7", "96.4", "", "", "", "", "95.0"]} +{"pcdb_id": 10309, "brand_name": "Saunier Duval", "model_name": "Xeon 30HE LPG", "model_qualifier": "", "winter_efficiency_pct": 90.0, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 59.2, "output_kw_max": 28.17, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010309", "000206", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Saunier Duval", "Xeon 30HE LPG", "", "", "2005", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "28.17", "28.17", "", "", "90.0", "81.0", "", "59.2", "", "2", "0", "", "102", "1", "2", "60", "15", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.8", "99.0", "", "", "", "", "97.3"]} +{"pcdb_id": 10310, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "12i System", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 12.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010310", "000035", "0", "2020/Sep/08 09:22", "Worcester Bosch Group", "Worcester", "Greenstar", "12i System", "41-311-67", "2005", "2015", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "12", "12", "", "", "88.1", "79.1", "", "57.7", "", "2", "", "", "102", "1", "2", "140", "5", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0305", "", "", "", "", "", "", "", "", "87.8", "97.0", "", "", "", "", "95.3"]} +{"pcdb_id": 10311, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "12i System", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 12.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010311", "000035", "0", "2020/Sep/08 09:22", "Worcester Bosch Group", "Worcester", "Greenstar", "12i System", "41-311-69", "2005", "2015", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "12", "12", "", "", "89.1", "80.1", "", "58.5", "", "2", "1", "", "102", "1", "2", "140", "5", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0305", "", "", "", "", "", "", "", "", "89.7", "99.2", "", "", "", "", "97.4"]} +{"pcdb_id": 10312, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "24i System", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 24.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010312", "000035", "0", "2020/Sep/08 09:23", "Worcester Bosch Group", "Worcester", "Greenstar", "24i System", "41-311-68", "2005", "2015", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24", "24", "", "", "88.5", "79.5", "", "58.0", "", "2", "", "", "102", "1", "2", "140", "5", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0305", "", "", "", "", "", "", "", "", "88.0", "97.9", "", "", "", "", "96.1"]} +{"pcdb_id": 10313, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "24i System", "winter_efficiency_pct": 89.5, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 58.8, "output_kw_max": 24.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010313", "000035", "0", "2020/Sep/08 09:23", "Worcester Bosch Group", "Worcester", "Greenstar", "24i System", "41-311-70", "2005", "2015", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "24", "24", "", "", "89.5", "80.5", "", "58.8", "", "2", "1", "", "102", "1", "2", "140", "5", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0305", "", "", "", "", "", "", "", "", "90.0", "100.1", "", "", "", "", "98.2"]} +{"pcdb_id": 10314, "brand_name": "Potterton", "model_name": "Promax System", "model_qualifier": "24 HE Plus", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 24.0, "final_year_of_manufacture": 2008, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010314", "000005", "0", "2012/Mar/27 10:12", "Baxi Potterton", "Potterton", "Promax System", "24 HE Plus", "GC No. 41-601-21", "2005", "2008", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24", "24", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "96.9", "", "", "", "", "95.1"]} +{"pcdb_id": 10315, "brand_name": "Potterton", "model_name": "Promax Combi", "model_qualifier": "28 HE Plus", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 55.8, "output_kw_max": 24.0, "final_year_of_manufacture": 2008, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010315", "000005", "0", "2010/Nov/19 09:19", "Baxi Potterton", "Potterton", "Promax Combi", "28 HE Plus", "GC No. 47-590-04", "2005", "2008", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "88.0", "79.4", "", "55.8", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "96.9", "", "", "", "", "95.2"]} +{"pcdb_id": 10316, "brand_name": "Potterton", "model_name": "Promax Combi", "model_qualifier": "33 HE Plus", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 55.8, "output_kw_max": 28.0, "final_year_of_manufacture": 2008, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010316", "000005", "0", "2010/Nov/19 09:19", "Baxi Potterton", "Potterton", "Promax Combi", "33 HE Plus", "GC No. 47-590-03", "2005", "2008", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28", "28", "", "", "87.9", "79.3", "", "55.8", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "96.7", "", "", "", "", "95.0"]} +{"pcdb_id": 10317, "brand_name": "Vaillant", "model_name": "Ecotec Plus", "model_qualifier": "618 LPG", "winter_efficiency_pct": 89.3, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 19.1, "final_year_of_manufacture": 2012, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010317", "000031", "0", "2019/Mar/04 09:14", "Vaillant", "Vaillant", "Ecotec Plus", "618 LPG", "", "2005", "2012", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "19.1", "19.1", "", "", "89.3", "80.3", "", "58.6", "", "2", "1", "", "102", "1", "2", "130", "65", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "92.0", "98.8", "", "", "", "", "97.5"]} +{"pcdb_id": 10318, "brand_name": "Vaillant", "model_name": "Ecotec Plus", "model_qualifier": "630 LPG", "winter_efficiency_pct": 89.3, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 31.8, "final_year_of_manufacture": 2012, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010318", "000031", "0", "2019/Mar/04 09:16", "Vaillant", "Vaillant", "Ecotec Plus", "630 LPG", "", "2005", "2012", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "31.8", "31.8", "", "", "89.3", "80.3", "", "58.6", "", "2", "1", "", "102", "1", "2", "130", "65", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "92.0", "98.8", "", "", "", "", "97.5"]} +{"pcdb_id": 10319, "brand_name": "Vaillant", "model_name": "Ecotec Plus", "model_qualifier": "831 LPG", "winter_efficiency_pct": 89.3, "summer_efficiency_pct": 80.7, "comparative_hot_water_efficiency_pct": 56.8, "output_kw_max": 25.5, "final_year_of_manufacture": 2012, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010319", "000031", "0", "2019/Mar/04 09:18", "Vaillant", "Vaillant", "Ecotec Plus", "831 LPG", "", "2005", "2012", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "25.5", "25.5", "", "", "89.3", "80.7", "", "56.8", "", "2", "1", "", "104", "1", "2", "130", "65", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "92.0", "98.9", "", "", "", "", "97.6"]} +{"pcdb_id": 10320, "brand_name": "Vaillant", "model_name": "Ecotec Plus", "model_qualifier": "612", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 12.7, "final_year_of_manufacture": 2012, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010320", "000031", "0", "2019/Mar/04 09:12", "Vaillant", "Vaillant", "Ecotec Plus", "612", "41-044-44", "2004", "2012", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "12.7", "12.7", "", "", "88.3", "79.3", "", "57.9", "", "2", "", "", "102", "1", "2", "130", "65", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.0", "96.7", "", "", "", "", "95.4"]} +{"pcdb_id": 10321, "brand_name": "Vaillant", "model_name": "Ecotec Plus", "model_qualifier": "615", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 15.9, "final_year_of_manufacture": 2012, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010321", "000031", "0", "2019/Mar/04 09:12", "Vaillant", "Vaillant", "Ecotec Plus", "615", "41-044-45", "2004", "2012", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "15.9", "15.9", "", "", "88.3", "79.3", "", "57.9", "", "2", "", "", "102", "1", "2", "130", "65", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.0", "96.7", "", "", "", "", "95.4"]} +{"pcdb_id": 10322, "brand_name": "Vaillant", "model_name": "Ecotec Plus", "model_qualifier": "618", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 19.1, "final_year_of_manufacture": 2012, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010322", "000031", "0", "2019/Mar/04 09:13", "Vaillant", "Vaillant", "Ecotec Plus", "618", "41-044-46", "2004", "2012", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "19.1", "19.1", "", "", "88.3", "79.3", "", "57.9", "", "2", "", "", "102", "1", "2", "130", "65", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.0", "96.7", "", "", "", "", "95.4"]} +{"pcdb_id": 10323, "brand_name": "Vaillant", "model_name": "Ecotec Plus", "model_qualifier": "624", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 25.5, "final_year_of_manufacture": 2012, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010323", "000031", "0", "2019/Mar/04 09:15", "Vaillant", "Vaillant", "Ecotec Plus", "624", "41-044-47", "2004", "2012", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "25.5", "25.5", "", "", "88.2", "79.2", "", "57.9", "", "2", "", "", "102", "1", "2", "130", "65", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.0", "96.6", "", "", "", "", "95.3"]} +{"pcdb_id": 10324, "brand_name": "Vaillant", "model_name": "Ecotec Plus", "model_qualifier": "630", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 31.8, "final_year_of_manufacture": 2012, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010324", "000031", "0", "2019/Mar/04 09:16", "Vaillant", "Vaillant", "Ecotec Plus", "630", "41-044-48", "2004", "2012", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "31.8", "31.8", "", "", "88.3", "79.3", "", "57.9", "", "2", "", "", "102", "1", "2", "130", "65", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.0", "96.7", "", "", "", "", "95.4"]} +{"pcdb_id": 10326, "brand_name": "Vaillant", "model_name": "Ecotec Plus", "model_qualifier": "824", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 62.2, "output_kw_max": 20.2, "final_year_of_manufacture": 2012, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010326", "000031", "0", "2019/Mar/04 09:17", "Vaillant", "Vaillant", "Ecotec Plus", "824", "47-044-31", "2004", "2012", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "20.2", "20.2", "", "", "88.3", "79.7", "", "62.2", "", "2", "", "", "104", "1", "2", "130", "65", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "", "0005", "", "", "", "", "", "", "", "", "90.1", "96.7", "", "", "", "", "95.4"]} +{"pcdb_id": 10327, "brand_name": "Vaillant", "model_name": "Ecotec Plus", "model_qualifier": "831", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 62.2, "output_kw_max": 25.5, "final_year_of_manufacture": 2012, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010327", "000031", "0", "2019/Mar/04 09:18", "Vaillant", "Vaillant", "Ecotec Plus", "831", "47-044-32", "2004", "2012", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "25.5", "25.5", "", "", "88.3", "79.7", "", "62.2", "", "2", "", "", "104", "1", "2", "130", "65", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "", "0005", "", "", "", "", "", "", "", "", "90.0", "96.8", "", "", "", "", "95.5"]} +{"pcdb_id": 10328, "brand_name": "Vaillant", "model_name": "Ecotec Pro", "model_qualifier": "28", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 62.2, "output_kw_max": 25.5, "final_year_of_manufacture": 2012, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010328", "000031", "0", "2019/Mar/04 10:24", "Vaillant", "Vaillant", "Ecotec Pro", "28", "47-044-30", "2004", "2012", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "25.5", "25.5", "", "", "88.2", "79.6", "", "62.2", "", "2", "", "", "104", "1", "2", "130", "65", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "", "0005", "", "", "", "", "", "", "", "", "90.0", "96.6", "", "", "", "", "95.3"]} +{"pcdb_id": 10330, "brand_name": "Kidd VHE", "model_name": "1", "model_qualifier": "Natural Gas", "winter_efficiency_pct": 84.0, "summer_efficiency_pct": 76.4, "comparative_hot_water_efficiency_pct": 55.8, "output_kw_max": 27.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010330", "000204", "0", "2012/Mar/27 10:12", "Archie Kidd (Thermal)", "Kidd VHE", "1", "Natural Gas", "", "", "current", "1", "1", "1", "1", "0", "", "", "2", "3", "2", "17.6", "27.2", "", "", "84.0", "76.4", "", "55.8", "", "2", "", "", "101", "1", "1", "75", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "86.2", "91.0", "", "", "", "", "90.1"]} +{"pcdb_id": 10331, "brand_name": "Kidd VHE", "model_name": "260", "model_qualifier": "Natural Gas", "winter_efficiency_pct": 84.3, "summer_efficiency_pct": 76.7, "comparative_hot_water_efficiency_pct": 56.0, "output_kw_max": null, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010331", "000204", "0", "2012/Mar/27 10:12", "Archie Kidd (Thermal)", "Kidd VHE", "260", "Natural Gas", "", "", "current", "1", "1", "1", "1", "0", "", "", "2", "3", "2", "58.6", ">70kW", "", "", "84.3", "76.7", "", "56.0", "", "2", "", "", "101", "1", "1", "75", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "87.3", "91.2", "", "", "", "", "90.4"]} +{"pcdb_id": 10333, "brand_name": "Kidd VHE", "model_name": "2", "model_qualifier": "Kerosene", "winter_efficiency_pct": 86.8, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 47.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010333", "000204", "0", "2012/Mar/27 10:12", "Archie Kidd (Thermal)", "Kidd VHE", "2", "Kerosene", "", "", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "29.3", "47", "", "", "86.8", "79.0", "", "57.7", "", "2", "", "", "201", "1", "1", "90", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "89.8", "92.2", "", "", "", "", "91.7"]} +{"pcdb_id": 10334, "brand_name": "Kidd VHE", "model_name": "260", "model_qualifier": "Kerosene", "winter_efficiency_pct": 86.4, "summer_efficiency_pct": 78.6, "comparative_hot_water_efficiency_pct": 57.4, "output_kw_max": null, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010334", "000204", "0", "2012/Mar/27 10:12", "Archie Kidd (Thermal)", "Kidd VHE", "260", "Kerosene", "", "", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "58.6", ">70kW", "", "", "86.4", "78.6", "", "57.4", "", "2", "", "", "201", "1", "1", "125", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "88.7", "92.2", "", "", "", "", "91.5"]} +{"pcdb_id": 10336, "brand_name": "Viessmann", "model_name": "Vitodens 100", "model_qualifier": "WB1A - 24kW", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 24.0, "final_year_of_manufacture": 2007, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010336", "000033", "0", "2012/Mar/27 10:12", "Viessmann", "Viessmann", "Vitodens 100", "WB1A - 24kW", "", "", "2007", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24", "24", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "165", "11", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "97.9", "", "", "", "", "96.0"]} +{"pcdb_id": 10337, "brand_name": "Viessmann", "model_name": "Vitodens 100 Combi", "model_qualifier": "WB1A 24kw", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 56.1, "output_kw_max": 24.0, "final_year_of_manufacture": 2007, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010337", "000033", "0", "2006/Jan/17 12:31", "Viessmann", "Viessmann", "Vitodens 100 Combi", "WB1A 24kw", "", "", "2007", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "88.4", "79.8", "", "56.1", "", "2", "", "", "104", "1", "2", "165", "11", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "97.9", "", "", "", "", "96.0"]} +{"pcdb_id": 10338, "brand_name": "Viessmann", "model_name": "Vitodens 100 Combi", "model_qualifier": "WB1A - 30kW", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 56.3, "output_kw_max": 30.0, "final_year_of_manufacture": 2007, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010338", "000033", "0", "2006/Jan/17 12:31", "Viessmann", "Viessmann", "Vitodens 100 Combi", "WB1A - 30kW", "", "", "2007", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "30", "30", "", "", "88.6", "80.0", "", "56.3", "", "2", "", "", "104", "1", "2", "165", "11", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "98.3", "", "", "", "", "96.3"]} +{"pcdb_id": 10339, "brand_name": "Grant", "model_name": "Vortex Condensing", "model_qualifier": "Combi 36", "winter_efficiency_pct": 90.5, "summer_efficiency_pct": 84.4, "comparative_hot_water_efficiency_pct": 46.2, "output_kw_max": 36.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 1, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010339", "000048", "0", "2024/Jan/31 10:17", "Grant Engineering", "Grant", "Vortex Condensing", "Combi 36", "", "2005", "current", "4", "1", "1", "2", "0", "", "", "2", "3", "2", "36", "36", "", "", "90.5", "84.4", "", "46.2", "", "2", "", "", "203", "1", "1", "", "", "1", "", "", "40", "0", "25", "3", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "0", "", "0003", "", "", "", "", "", "", "", "", "95.1", "99.3", "", "", "", "", "98.5"]} +{"pcdb_id": 10340, "brand_name": "Grant", "model_name": "Vortex Condensing", "model_qualifier": "Combi 26", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 83.0, "comparative_hot_water_efficiency_pct": 45.4, "output_kw_max": 26.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 1, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010340", "000048", "0", "2024/Jan/31 10:17", "Grant Engineering", "Grant", "Vortex Condensing", "Combi 26", "", "2005", "current", "4", "1", "1", "2", "0", "", "", "2", "3", "2", "26", "26", "", "", "89.1", "83.0", "", "45.4", "", "2", "", "", "203", "1", "1", "", "", "1", "", "", "40", "0", "25", "3", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "93.6", "96.4", "", "", "", "", "95.9"]} +{"pcdb_id": 10341, "brand_name": "Grant", "model_name": "Outdoor", "model_qualifier": "Combi Max", "winter_efficiency_pct": 83.2, "summer_efficiency_pct": 73.7, "comparative_hot_water_efficiency_pct": 51.8, "output_kw_max": 33.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010341", "000048", "0", "2005/May/31 11:57", "Grant Engineering", "Grant", "Outdoor", "Combi Max", "", "2005", "current", "4", "1", "2", "2", "0", "", "", "1", "3", "2", "33.3", "33.3", "", "", "83.2", "73.7", "", "51.8", "", "2", "", "", "202", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "84.8", "85.2", "", "", "", "", "85.1"]} +{"pcdb_id": 10342, "brand_name": "Grant", "model_name": "Combi Max", "model_qualifier": "", "winter_efficiency_pct": 83.2, "summer_efficiency_pct": 73.7, "comparative_hot_water_efficiency_pct": 51.8, "output_kw_max": 33.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010342", "000048", "0", "2005/May/31 11:57", "Grant Engineering", "Grant", "Combi Max", "", "", "2005", "current", "4", "1", "1", "2", "0", "", "", "1", "3", "2", "33.3", "33.3", "", "", "83.2", "73.7", "", "51.8", "", "2", "", "", "202", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "84.8", "85.2", "", "", "", "", "85.1"]} +{"pcdb_id": 10343, "brand_name": "Grant", "model_name": "Outdoor", "model_qualifier": "Combi 90 V3", "winter_efficiency_pct": 83.7, "summer_efficiency_pct": 74.2, "comparative_hot_water_efficiency_pct": 52.1, "output_kw_max": 26.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010343", "000048", "0", "2005/Jun/09 17:48", "Grant Engineering", "Grant", "Outdoor", "Combi 90 V3", "", "2005", "current", "4", "1", "2", "2", "0", "", "", "1", "3", "2", "26.4", "26.4", "", "", "83.7", "74.2", "", "52.1", "", "2", "", "", "202", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.6", "84.7", "", "", "", "", "85.1"]} +{"pcdb_id": 10344, "brand_name": "Grant", "model_name": "Combi 90 V3", "model_qualifier": "", "winter_efficiency_pct": 83.7, "summer_efficiency_pct": 74.2, "comparative_hot_water_efficiency_pct": 52.1, "output_kw_max": 26.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010344", "000048", "0", "2005/Jun/09 17:48", "Grant Engineering", "Grant", "Combi 90 V3", "", "", "2005", "current", "4", "1", "1", "2", "0", "", "", "1", "3", "2", "26.4", "26.4", "", "", "83.7", "74.2", "", "52.1", "", "2", "", "", "202", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.6", "84.7", "", "", "", "", "85.1"]} +{"pcdb_id": 10345, "brand_name": "Grant", "model_name": "Combi", "model_qualifier": "70 V3", "winter_efficiency_pct": 84.0, "summer_efficiency_pct": 74.5, "comparative_hot_water_efficiency_pct": 52.4, "output_kw_max": 20.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010345", "000048", "0", "2005/May/31 11:58", "Grant Engineering", "Grant", "Combi", "70 V3", "", "2005", "current", "4", "1", "1", "2", "0", "", "", "1", "3", "2", "20.5", "20.5", "", "", "84.0", "74.5", "", "52.4", "", "2", "", "", "202", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.3", "86.3", "", "", "", "", "86.1"]} +{"pcdb_id": 10346, "brand_name": "Potterton", "model_name": "Promax", "model_qualifier": "30 HE Plus", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 30.18, "final_year_of_manufacture": 2010, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010346", "000005", "0", "2012/Mar/27 10:12", "Baxi Potterton", "Potterton", "Promax", "30 HE Plus", "GC No. 41-601-22", "2005", "2010", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "30.18", "30.18", "", "", "88.1", "79.1", "", "57.8", "", "2", "", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.4", "96.4", "", "", "", "", "95.1"]} +{"pcdb_id": 10347, "brand_name": "Worcester", "model_name": "Greenstar Utility", "model_qualifier": "50/70-000-GB", "winter_efficiency_pct": 87.7, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 70.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010347", "000035", "0", "2020/Sep/08 09:23", "Worcester Heat Systems", "Worcester", "Greenstar Utility", "50/70-000-GB", "", "2005", "2015", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "50", "70", "", "", "87.7", "79.9", "", "58.4", "", "2", "", "", "201", "1", "1", "220", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.0", "94.0", "", "", "", "", "93.4"]} +{"pcdb_id": 10348, "brand_name": "Worcester", "model_name": "Greenstar Utility", "model_qualifier": "32/50-000-GB", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 50.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010348", "000035", "0", "2020/Sep/08 09:23", "Worcester Heat Systems", "Worcester", "Greenstar Utility", "32/50-000-GB", "", "2005", "2015", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "32", "50", "", "", "87.9", "80.1", "", "58.5", "", "2", "", "", "201", "1", "1", "190", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.6", "94.3", "", "", "", "", "93.8"]} +{"pcdb_id": 10349, "brand_name": "Ideal", "model_name": "mini", "model_qualifier": "HE C24 LPG", "winter_efficiency_pct": 86.2, "summer_efficiency_pct": 77.6, "comparative_hot_water_efficiency_pct": 54.5, "output_kw_max": 23.7, "final_year_of_manufacture": 2011, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010349", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "mini", "HE C24 LPG", "47-348-38", "2004", "2011", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "23.7", "23.7", "", "", "86.2", "77.6", "", "54.5", "", "2", "0", "", "104", "1", "2", "140", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.3", "90.8", "", "", "", "", "90.1"]} +{"pcdb_id": 10350, "brand_name": "Ideal", "model_name": "mini", "model_qualifier": "HE C28 LPG", "winter_efficiency_pct": 86.3, "summer_efficiency_pct": 77.7, "comparative_hot_water_efficiency_pct": 54.6, "output_kw_max": 27.4, "final_year_of_manufacture": 2011, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010350", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "mini", "HE C28 LPG", "47-348-39", "2004", "2011", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "27.4", "27.4", "", "", "86.3", "77.7", "", "54.6", "", "2", "0", "", "104", "1", "2", "150", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.1", "91.4", "", "", "", "", "90.6"]} +{"pcdb_id": 10352, "brand_name": "Worcester", "model_name": "Greenstar Cdi", "model_qualifier": "40 Cdi", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 56.4, "output_kw_max": 30.0, "final_year_of_manufacture": 2007, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010352", "000035", "0", "2020/Sep/08 09:23", "Worcester Bosch Group", "Worcester", "Greenstar Cdi", "40 Cdi", "47-311-95", "2005", "2007", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "30.0", "30.0", "", "", "88.8", "80.2", "", "56.4", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0305", "", "", "", "", "", "", "", "", "88.1", "98.8", "", "", "", "", "96.8"]} +{"pcdb_id": 10353, "brand_name": "Worcester", "model_name": "Greenstar Cdi", "model_qualifier": "40 Cdi", "winter_efficiency_pct": 89.8, "summer_efficiency_pct": 81.2, "comparative_hot_water_efficiency_pct": 57.1, "output_kw_max": 30.0, "final_year_of_manufacture": 2007, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010353", "000035", "0", "2020/Sep/08 09:24", "Worcester Bosch Group", "Worcester", "Greenstar Cdi", "40 Cdi", "47-406-01", "2005", "2007", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "30", "30", "", "", "89.8", "81.2", "", "57.1", "", "2", "1", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0305", "", "", "", "", "", "", "", "", "90.1", "101.0", "", "", "", "", "99.0"]} +{"pcdb_id": 10354, "brand_name": "Worcester", "model_name": "Greenstar Cdi", "model_qualifier": "40 Cdi Conventional", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 40.8, "final_year_of_manufacture": 2014, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010354", "000035", "0", "2020/Sep/08 09:24", "Worcester Bosch Group", "Worcester", "Greenstar Cdi", "40 Cdi Conventional", "41-311-72", "2005", "2014", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "40.8", "40.8", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "97.9", "", "", "", "", "96.0"]} +{"pcdb_id": 10355, "brand_name": "Worcester", "model_name": "Greenstar Cdi", "model_qualifier": "40 Cdi Conventional", "winter_efficiency_pct": 89.5, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 58.8, "output_kw_max": 40.8, "final_year_of_manufacture": 2014, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010355", "000035", "0", "2020/Sep/08 09:24", "Worcester Bosch Group", "Worcester", "Greenstar Cdi", "40 Cdi Conventional", "41-311-74", "2005", "2014", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "40.8", "40.8", "", "", "89.5", "80.5", "", "58.8", "", "2", "1", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.9", "100.1", "", "", "", "", "98.2"]} +{"pcdb_id": 10356, "brand_name": "Worcester", "model_name": "Greenstar Cdi", "model_qualifier": "30 Cdi Conventional", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 30.0, "final_year_of_manufacture": 2014, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010356", "000035", "0", "2020/Sep/08 09:24", "Worcester Bosch Group", "Worcester", "Greenstar Cdi", "30 Cdi Conventional", "41-311-71", "2005", "2014", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "30.0", "30.0", "", "", "88.8", "79.8", "", "58.3", "", "2", "", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.1", "98.8", "", "", "", "", "96.8"]} +{"pcdb_id": 10357, "brand_name": "Worcester", "model_name": "Greenstar Cdi", "model_qualifier": "30 Cdi Conventional", "winter_efficiency_pct": 89.8, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 59.1, "output_kw_max": 30.0, "final_year_of_manufacture": 2014, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010357", "000035", "0", "2020/Sep/08 09:24", "Worcester Bosch Group", "Worcester", "Greenstar Cdi", "30 Cdi Conventional", "41-311-73", "2005", "2014", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "30", "30", "", "", "89.8", "80.8", "", "59.1", "", "2", "1", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.1", "101.0", "", "", "", "", "99.0"]} +{"pcdb_id": 10359, "brand_name": "Ravenheat", "model_name": "CSI systemT Low Nox", "model_qualifier": "Timeclock Natural Gas", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 25.74, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010359", "000026", "0", "2012/Mar/27 10:12", "Ravenheat Manufacturing", "Ravenheat", "CSI systemT Low Nox", "Timeclock Natural Gas", "", "2005", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "25.74", "25.74", "", "", "88.8", "79.8", "", "58.3", "", "2", "", "", "102", "1", "2", "40", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.2", "98.4", "", "", "", "", "96.6"]} +{"pcdb_id": 10360, "brand_name": "Ravenheat", "model_name": "CSI system Low Nox", "model_qualifier": "Natural Gas", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 25.87, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010360", "000026", "0", "2012/Mar/27 10:12", "Ravenheat Manufacturing", "Ravenheat", "CSI system Low Nox", "Natural Gas", "", "2005", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "25.87", "25.87", "", "", "88.8", "79.8", "", "58.3", "", "2", "", "", "102", "1", "2", "40", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.2", "98.4", "", "", "", "", "96.6"]} +{"pcdb_id": 10361, "brand_name": "Ravenheat", "model_name": "CSI primary Low Nox", "model_qualifier": "Natural Gas", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 25.87, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010361", "000026", "0", "2012/Mar/27 10:12", "Ravenheat Manufacturing", "Ravenheat", "CSI primary Low Nox", "Natural Gas", "", "2005", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "25.87", "25.87", "", "", "88.8", "79.8", "", "58.3", "", "2", "", "", "102", "1", "2", "40", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.2", "98.4", "", "", "", "", "96.6"]} +{"pcdb_id": 10362, "brand_name": "Ravenheat", "model_name": "CSI 120T Low Nox", "model_qualifier": "Timeclock Natural Gas", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 56.4, "output_kw_max": 25.87, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010362", "000026", "0", "2010/Sep/29 12:16", "Ravenheat Manufacturing", "Ravenheat", "CSI 120T Low Nox", "Timeclock Natural Gas", "", "2005", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "25.87", "25.87", "", "", "88.8", "80.2", "", "56.4", "", "2", "", "", "104", "1", "2", "160", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.2", "98.4", "", "", "", "", "96.6"]} +{"pcdb_id": 10363, "brand_name": "Ravenheat", "model_name": "CSI 120 Low Nox", "model_qualifier": "Natural Gas", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 56.4, "output_kw_max": 25.87, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010363", "000026", "0", "2010/Sep/29 12:16", "Ravenheat Manufacturing", "Ravenheat", "CSI 120 Low Nox", "Natural Gas", "", "2005", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "25.87", "25.87", "", "", "88.8", "80.2", "", "56.4", "", "2", "", "", "104", "1", "2", "160", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.2", "98.4", "", "", "", "", "96.6"]} +{"pcdb_id": 10370, "brand_name": "Wolf", "model_name": "CGB-K-20", "model_qualifier": "", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 80.6, "comparative_hot_water_efficiency_pct": 56.7, "output_kw_max": 20.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010370", "000240", "0", "2006/Mar/29 12:49", "Wolf", "Wolf", "CGB-K-20", "", "8611310", "2003", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "20.5", "20.5", "", "", "89.2", "80.6", "", "56.7", "", "2", "1", "", "104", "1", "2", "22", "7", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.1", "99.4", "", "", "", "", "97.6"]} +{"pcdb_id": 10371, "brand_name": "Wolf", "model_name": "CGB-20", "model_qualifier": "", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 20.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010371", "000240", "0", "2012/Mar/27 10:12", "Wolf", "Wolf", "CGB-20", "", "8611308", "2003", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "20.5", "20.5", "", "", "89.2", "80.2", "", "58.6", "", "2", "1", "", "102", "1", "2", "22", "7", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.1", "99.4", "", "", "", "", "97.6"]} +{"pcdb_id": 10372, "brand_name": "Wolf", "model_name": "CGB-K-24", "model_qualifier": "", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 56.6, "output_kw_max": 24.8, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010372", "000240", "0", "2006/Mar/29 12:50", "Wolf", "Wolf", "CGB-K-24", "", "8611314", "2004", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24.8", "24.8", "", "", "89.1", "80.5", "", "56.6", "", "2", "1", "", "104", "1", "2", "18", "7", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.9", "99.3", "", "", "", "", "97.5"]} +{"pcdb_id": 10373, "brand_name": "Wolf", "model_name": "CGB-24", "model_qualifier": "", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 56.6, "output_kw_max": 24.8, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010373", "000240", "0", "2006/Mar/29 12:51", "Wolf", "Wolf", "CGB-24", "", "8611312", "2004", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24.8", "24.8", "", "", "89.1", "80.5", "", "56.6", "", "2", "1", "", "104", "1", "2", "18", "7", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.9", "99.3", "", "", "", "", "97.5"]} +{"pcdb_id": 10374, "brand_name": "Wolf", "model_name": "CGB-K-20", "model_qualifier": "", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 56.0, "output_kw_max": 20.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010374", "000240", "0", "2006/Mar/29 12:46", "Wolf", "Wolf", "CGB-K-20", "", "8611309", "2003", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "20.5", "20.5", "", "", "88.2", "79.6", "", "56.0", "", "2", "", "", "104", "1", "2", "22", "7", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.1", "97.2", "", "", "", "", "95.5"]} +{"pcdb_id": 10375, "brand_name": "Wolf", "model_name": "CGB-20", "model_qualifier": "", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 20.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010375", "000240", "0", "2012/Mar/27 10:12", "Wolf", "Wolf", "CGB-20", "", "8611307", "2003", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "20.5", "20.5", "", "", "88.2", "79.2", "", "57.8", "", "2", "", "", "102", "1", "2", "22", "7", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.1", "97.2", "", "", "", "", "95.5"]} +{"pcdb_id": 10376, "brand_name": "Wolf", "model_name": "CGB-K-24", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 55.9, "output_kw_max": 24.8, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010376", "000240", "0", "2006/Mar/29 12:47", "Wolf", "Wolf", "CGB-K-24", "", "8611313", "2004", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.8", "24.8", "", "", "88.1", "79.5", "", "55.9", "", "2", "", "", "104", "1", "2", "18", "7", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "97.1", "", "", "", "", "95.4"]} +{"pcdb_id": 10377, "brand_name": "Wolf", "model_name": "CGB-24", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 24.8, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010377", "000240", "0", "2012/Mar/27 10:12", "Wolf", "Wolf", "CGB-24", "", "8611311", "2004", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24.8", "24.8", "", "", "88.1", "79.1", "", "57.8", "", "2", "", "", "102", "1", "2", "18", "7", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "97.1", "", "", "", "", "95.4"]} +{"pcdb_id": 10378, "brand_name": "Wolf", "model_name": "CGB-11", "model_qualifier": "", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 10.9, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010378", "000240", "0", "2012/Mar/27 10:12", "Wolf", "Wolf", "CGB-11", "", "8611306", "2004", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "10.9", "10.9", "", "", "88.2", "79.2", "", "57.9", "", "2", "", "", "102", "1", "2", "15", "7", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "97.4", "", "", "", "", "95.6"]} +{"pcdb_id": 10379, "brand_name": "Wolf", "model_name": "TGG-18", "model_qualifier": "Topline Boiler", "winter_efficiency_pct": 83.3, "summer_efficiency_pct": 72.6, "comparative_hot_water_efficiency_pct": 53.0, "output_kw_max": 18.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010379", "000240", "0", "2012/Mar/27 10:12", "Wolf", "Wolf", "TGG-18", "Topline Boiler", "8602756", "2001", "current", "2", "2", "1", "1", "0", "", "", "1", "2", "2", "18.0", "18.0", "", "", "83.3", "72.6", "", "53.0", "", "2", "1", "", "102", "1", "2", "44", "8", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "84.8", "84.9", "", "", "", "", "84.9"]} +{"pcdb_id": 10381, "brand_name": "Wolf", "model_name": "TGG-K-18", "model_qualifier": "Topline Combi Boiler", "winter_efficiency_pct": 83.1, "summer_efficiency_pct": 73.0, "comparative_hot_water_efficiency_pct": 51.3, "output_kw_max": 18.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010381", "000240", "0", "2006/Jan/17 12:31", "Wolf", "Wolf", "TGG-K-18", "Topline Combi Boiler", "8602754", "2001", "current", "2", "2", "1", "2", "0", "", "", "1", "2", "2", "18.0", "18.0", "", "", "83.1", "73.0", "", "51.3", "", "2", "1", "", "104", "1", "2", "44", "8", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "84.7", "84.9", "", "", "", "", "84.9"]} +{"pcdb_id": 10382, "brand_name": "Wolf", "model_name": "TGG-K-24", "model_qualifier": "Topline Combi Boiler", "winter_efficiency_pct": 83.1, "summer_efficiency_pct": 73.0, "comparative_hot_water_efficiency_pct": 51.3, "output_kw_max": 24.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010382", "000240", "0", "2006/Jan/17 12:31", "Wolf", "Wolf", "TGG-K-24", "Topline Combi Boiler", "8602760", "2001", "current", "2", "2", "1", "2", "0", "", "", "1", "2", "2", "24.0", "24.0", "", "", "83.1", "73.0", "", "51.3", "", "2", "1", "", "104", "1", "2", "44", "8", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "84.7", "84.8", "", "", "", "", "84.8"]} +{"pcdb_id": 10383, "brand_name": "Wolf", "model_name": "TGG-24", "model_qualifier": "Topline Boiler", "winter_efficiency_pct": 83.3, "summer_efficiency_pct": 72.6, "comparative_hot_water_efficiency_pct": 53.0, "output_kw_max": 24.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010383", "000240", "0", "2012/Mar/27 10:12", "Wolf", "Wolf", "TGG-24", "Topline Boiler", "8602760", "2001", "current", "2", "2", "1", "1", "0", "", "", "1", "2", "2", "24.0", "24.0", "", "", "83.3", "72.6", "", "53.0", "", "2", "1", "", "102", "1", "2", "44", "8", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "84.7", "84.8", "", "", "", "", "84.8"]} +{"pcdb_id": 10384, "brand_name": "Wolf", "model_name": "TGG-K-18", "model_qualifier": "Topline Combi Boiler", "winter_efficiency_pct": 81.8, "summer_efficiency_pct": 71.7, "comparative_hot_water_efficiency_pct": 50.4, "output_kw_max": 18.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010384", "000240", "0", "2006/Jan/17 12:31", "Wolf", "Wolf", "TGG-K-18", "Topline Combi Boiler", "8602753", "2001", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "18.0", "18.0", "", "", "81.8", "71.7", "", "50.4", "", "2", "", "", "104", "1", "2", "44", "8", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.9", "83.1", "", "", "", "", "83.0"]} +{"pcdb_id": 10385, "brand_name": "Wolf", "model_name": "TGG-18", "model_qualifier": "Topline Boiler", "winter_efficiency_pct": 82.0, "summer_efficiency_pct": 71.3, "comparative_hot_water_efficiency_pct": 52.1, "output_kw_max": 18.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010385", "000240", "0", "2012/Mar/27 10:12", "Wolf", "Wolf", "TGG-18", "Topline Boiler", "8602755", "2001", "current", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "18.0", "18.0", "", "", "82.0", "71.3", "", "52.1", "", "2", "", "", "102", "1", "2", "44", "8", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.9", "83.1", "", "", "", "", "83.0"]} +{"pcdb_id": 10386, "brand_name": "Wolf", "model_name": "TGG-K-24", "model_qualifier": "Topline Combi Boiler", "winter_efficiency_pct": 81.7, "summer_efficiency_pct": 71.6, "comparative_hot_water_efficiency_pct": 50.4, "output_kw_max": 24.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010386", "000240", "0", "2006/Jan/17 12:31", "Wolf", "Wolf", "TGG-K-24", "Topline Combi Boiler", "8602757", "2001", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "24.0", "24.0", "", "", "81.7", "71.6", "", "50.4", "", "2", "", "", "104", "1", "2", "44", "8", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.9", "83.0", "", "", "", "", "83.0"]} +{"pcdb_id": 10387, "brand_name": "Wolf", "model_name": "TGG-24", "model_qualifier": "Topline Boiler", "winter_efficiency_pct": 81.9, "summer_efficiency_pct": 71.2, "comparative_hot_water_efficiency_pct": 52.0, "output_kw_max": 24.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010387", "000240", "0", "2012/Mar/27 10:12", "Wolf", "Wolf", "TGG-24", "Topline Boiler", "8602759", "2001", "current", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "24.0", "24.0", "", "", "81.9", "71.2", "", "52.0", "", "2", "", "", "102", "1", "2", "44", "8", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.9", "83.0", "", "", "", "", "83.0"]} +{"pcdb_id": 10388, "brand_name": "Ideal", "model_name": "Mexico", "model_qualifier": "HE 36", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 37.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010388", "000008", "0", "2012/Mar/27 10:12", "Ideal Boilers", "Ideal", "Mexico", "HE 36", "41-415-20", "2005", "current", "1", "1", "1", "1", "0", "", "", "2", "2", "2", "37.0", "37.0", "", "", "88.3", "79.3", "", "57.9", "", "2", "", "", "102", "1", "2", "42", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.0", "97.2", "", "", "", "", "95.7"]} +{"pcdb_id": 10389, "brand_name": "Ideal", "model_name": "Mexico", "model_qualifier": "HE 30", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 30.1, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010389", "000008", "0", "2012/Mar/27 10:12", "Ideal Boilers", "Ideal", "Mexico", "HE 30", "41-429-99", "2005", "current", "1", "1", "1", "1", "0", "", "", "2", "2", "2", "30.1", "30.1", "", "", "88.2", "79.2", "", "57.9", "", "2", "", "", "102", "1", "2", "42", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.5", "97.1", "", "", "", "", "95.5"]} +{"pcdb_id": 10390, "brand_name": "Ideal", "model_name": "Mexico", "model_qualifier": "HE 24", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 23.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010390", "000008", "0", "2012/Mar/27 10:12", "Ideal Boilers", "Ideal", "Mexico", "HE 24", "41-429-98", "2005", "current", "1", "1", "1", "1", "0", "", "", "2", "2", "2", "23.4", "23.4", "", "", "88.1", "79.1", "", "57.8", "", "2", "", "", "102", "1", "2", "38", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "97.1", "", "", "", "", "95.4"]} +{"pcdb_id": 10391, "brand_name": "Ideal", "model_name": "Mexico", "model_qualifier": "HE18", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 18.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010391", "000008", "0", "2012/Mar/27 10:12", "Ideal Boilers", "Ideal", "Mexico", "HE18", "41-429-65", "2005", "current", "1", "1", "1", "1", "0", "", "", "2", "2", "2", "18.2", "18.2", "", "", "88.7", "79.7", "", "58.2", "", "2", "", "", "102", "1", "2", "38", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.2", "98.5", "", "", "", "", "96.5"]} +{"pcdb_id": 10392, "brand_name": "Ideal", "model_name": "Mexico", "model_qualifier": "HE15", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 14.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010392", "000008", "0", "2012/Jun/28 10:57", "Ideal Boilers", "Ideal", "Mexico", "HE15", "41-429-39", "2005", "current", "1", "1", "1", "1", "0", "", "", "2", "2", "2", "14.6", "14.6", "", "", "89.0", "80.0", "", "58.4", "", "2", "", "", "102", "1", "2", "38", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.5", "99.0", "", "", "", "", "97.0"]} +{"pcdb_id": 10393, "brand_name": "Vokera", "model_name": "Linea HE", "model_qualifier": "25HE", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 55.8, "output_kw_max": 24.4, "final_year_of_manufacture": 2010, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010393", "000011", "0", "2010/Oct/21 11:11", "Vokera", "Vokera", "Linea HE", "25HE", "4709460", "2005", "2010", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.4", "24.4", "", "", "87.9", "79.3", "", "55.8", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "96.5", "", "", "", "", "94.9"]} +{"pcdb_id": 10394, "brand_name": "Vokera", "model_name": "Linea HE", "model_qualifier": "25HE LPG", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 56.6, "output_kw_max": 24.0, "final_year_of_manufacture": 2010, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010394", "000011", "0", "2010/Oct/21 11:11", "Vokera", "Vokera", "Linea HE", "25HE LPG", "4709461", "2005", "2010", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "89.1", "80.5", "", "56.6", "", "2", "0", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.5", "97.2", "", "", "", "", "95.5"]} +{"pcdb_id": 10395, "brand_name": "Vokera", "model_name": "Linea HE", "model_qualifier": "30HE", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 55.9, "output_kw_max": 29.4, "final_year_of_manufacture": 2010, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010395", "000011", "0", "2010/Oct/21 11:12", "Vokera", "Vokera", "Linea HE", "30HE", "4709462", "2005", "2010", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "29.4", "29.4", "", "", "88.1", "79.5", "", "55.9", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.4", "96.9", "", "", "", "", "95.3"]} +{"pcdb_id": 10396, "brand_name": "Vokera", "model_name": "Linea HE", "model_qualifier": "30HE LPG", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 56.9, "output_kw_max": 29.0, "final_year_of_manufacture": 2010, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010396", "000011", "0", "2010/Oct/21 11:12", "Vokera", "Vokera", "Linea HE", "30HE LPG", "4709463", "2005", "2010", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "29", "29", "", "", "89.4", "80.8", "", "56.9", "", "2", "0", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.0", "97.9", "", "", "", "", "96.2"]} +{"pcdb_id": 10397, "brand_name": "Vokera", "model_name": "Linea HE", "model_qualifier": "35HE", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 56.1, "output_kw_max": 33.7, "final_year_of_manufacture": 2010, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010397", "000011", "0", "2010/Oct/21 11:12", "Vokera", "Vokera", "Linea HE", "35HE", "4709464", "2005", "2010", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "33.7", "33.7", "", "", "88.4", "79.8", "", "56.1", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "97.8", "", "", "", "", "95.9"]} +{"pcdb_id": 10398, "brand_name": "Vokera", "model_name": "Linea HE", "model_qualifier": "35HE LPG", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 56.5, "output_kw_max": 33.3, "final_year_of_manufacture": 2010, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010398", "000011", "0", "2010/Oct/21 11:13", "Vokera", "Vokera", "Linea HE", "35HE LPG", "4709465", "2005", "2010", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "33.3", "33.3", "", "", "88.9", "80.3", "", "56.5", "", "2", "0", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.5", "96.8", "", "", "", "", "95.2"]} +{"pcdb_id": 10399, "brand_name": "Heating World Group", "model_name": "Grandee Combi Condensing External", "model_qualifier": "W 15/22", "winter_efficiency_pct": 87.4, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 56.2, "output_kw_max": 21.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010399", "000050", "0", "2006/Jul/28 13:39", "Heating World Group", "Heating World Group", "Grandee Combi Condensing External", "W 15/22", "", "2005", "current", "4", "2", "2", "2", "0", "", "", "2", "3", "1", "15", "21", "", "", "87.4", "80.0", "", "56.2", "", "2", "", "", "202", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.4", "93.3", "", "", "", "", "92.8"]} +{"pcdb_id": 10400, "brand_name": "Heating World Group", "model_name": "Grandee System Condensing External", "model_qualifier": "W 15/22", "winter_efficiency_pct": 87.4, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 21.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010400", "000050", "0", "2012/Mar/27 10:12", "Heating World Group", "Heating World Group", "Grandee System Condensing External", "W 15/22", "", "2005", "current", "4", "2", "2", "1", "0", "", "", "2", "3", "1", "15", "21", "", "", "87.4", "79.6", "", "58.1", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.4", "93.3", "", "", "", "", "92.8"]} +{"pcdb_id": 10401, "brand_name": "Heating World Group", "model_name": "Grandee Standard Condensing External", "model_qualifier": "W 15/22", "winter_efficiency_pct": 87.4, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 21.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010401", "000050", "0", "2012/Mar/27 10:12", "Heating World Group", "Heating World Group", "Grandee Standard Condensing External", "W 15/22", "", "2005", "current", "4", "2", "2", "1", "0", "", "", "2", "3", "1", "15", "21", "", "", "87.4", "79.6", "", "58.1", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.4", "93.3", "", "", "", "", "92.8"]} +{"pcdb_id": 10402, "brand_name": "Heating World Group", "model_name": "Grandee Combi Condensing", "model_qualifier": "W 15/22", "winter_efficiency_pct": 87.4, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 56.2, "output_kw_max": 21.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010402", "000050", "0", "2006/Jul/28 13:40", "Heating World Group", "Heating World Group", "Grandee Combi Condensing", "W 15/22", "", "2005", "current", "4", "2", "1", "2", "0", "", "", "2", "3", "1", "15", "21", "", "", "87.4", "80.0", "", "56.2", "", "2", "", "", "202", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.4", "93.3", "", "", "", "", "92.8"]} +{"pcdb_id": 10403, "brand_name": "Heating World Group", "model_name": "Grandee System Condensing", "model_qualifier": "W 15/22", "winter_efficiency_pct": 87.4, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 21.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010403", "000050", "0", "2012/Mar/27 10:12", "Heating World Group", "Heating World Group", "Grandee System Condensing", "W 15/22", "", "2005", "current", "4", "2", "1", "1", "0", "", "", "2", "3", "1", "15", "21", "", "", "87.4", "79.6", "", "58.1", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.4", "93.3", "", "", "", "", "92.8"]} +{"pcdb_id": 10404, "brand_name": "Heating World Group", "model_name": "Grandee Standard Condensing", "model_qualifier": "W 15/22", "winter_efficiency_pct": 87.4, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 21.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010404", "000050", "0", "2012/Mar/27 10:12", "Heating World Group", "Heating World Group", "Grandee Standard Condensing", "W 15/22", "", "2005", "current", "4", "2", "1", "1", "0", "", "", "2", "3", "1", "15", "21", "", "", "87.4", "79.6", "", "58.1", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.4", "93.3", "", "", "", "", "92.8"]} +{"pcdb_id": 10405, "brand_name": "Heating World Group", "model_name": "Grandee Combi Condensing External", "model_qualifier": "W 23/28", "winter_efficiency_pct": 87.0, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 56.0, "output_kw_max": 26.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010405", "000050", "0", "2006/Jul/28 13:41", "Heating World Group", "Heating World Group", "Grandee Combi Condensing External", "W 23/28", "", "2005", "current", "4", "2", "2", "2", "0", "", "", "2", "3", "1", "23", "26", "", "", "87.0", "79.6", "", "56.0", "", "2", "", "", "202", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.1", "92.6", "", "", "", "", "92.1"]} +{"pcdb_id": 10406, "brand_name": "Heating World Group", "model_name": "Grandee System Condensing External", "model_qualifier": "W 23/28", "winter_efficiency_pct": 87.0, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 26.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010406", "000050", "0", "2012/Mar/27 10:12", "Heating World Group", "Heating World Group", "Grandee System Condensing External", "W 23/28", "", "2005", "current", "4", "2", "2", "1", "0", "", "", "2", "3", "1", "23", "26", "", "", "87.0", "79.2", "", "57.9", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.1", "92.6", "", "", "", "", "92.1"]} +{"pcdb_id": 10407, "brand_name": "Heating World Group", "model_name": "Grandee Standard Condensing External", "model_qualifier": "W 23/28", "winter_efficiency_pct": 87.0, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 26.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010407", "000050", "0", "2012/Mar/27 10:12", "Heating World Group", "Heating World Group", "Grandee Standard Condensing External", "W 23/28", "", "2005", "current", "4", "2", "2", "1", "0", "", "", "2", "3", "1", "23", "26", "", "", "87.0", "79.2", "", "57.9", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.1", "92.6", "", "", "", "", "92.1"]} +{"pcdb_id": 10408, "brand_name": "Heating World Group", "model_name": "Grandee Combi Condensing", "model_qualifier": "W 23/28", "winter_efficiency_pct": 87.0, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 56.0, "output_kw_max": 26.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010408", "000050", "0", "2006/Jul/28 13:42", "Heating World Group", "Heating World Group", "Grandee Combi Condensing", "W 23/28", "", "2005", "current", "4", "2", "1", "2", "0", "", "", "2", "3", "1", "23", "26", "", "", "87.0", "79.6", "", "56.0", "", "2", "", "", "202", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.1", "92.6", "", "", "", "", "92.1"]} +{"pcdb_id": 10409, "brand_name": "Heating World Group", "model_name": "Grandee System Condensing", "model_qualifier": "W 23/28", "winter_efficiency_pct": 87.0, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 26.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010409", "000050", "0", "2012/Mar/27 10:12", "Heating World Group", "Heating World Group", "Grandee System Condensing", "W 23/28", "", "2005", "current", "4", "2", "1", "1", "0", "", "", "2", "3", "1", "23", "26", "", "", "87.0", "79.2", "", "57.9", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.1", "92.6", "", "", "", "", "92.1"]} +{"pcdb_id": 10410, "brand_name": "Heating World Group", "model_name": "Grandee Standard Condensing", "model_qualifier": "W 23/28", "winter_efficiency_pct": 87.0, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 26.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010410", "000050", "0", "2012/Mar/27 10:12", "Heating World Group", "Heating World Group", "Grandee Standard Condensing", "W 23/28", "", "2005", "current", "4", "2", "1", "1", "0", "", "", "2", "3", "1", "23", "26", "", "", "87.0", "79.2", "", "57.9", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.1", "92.6", "", "", "", "", "92.1"]} +{"pcdb_id": 10411, "brand_name": "Heating World Group", "model_name": "Grandee Combi Condensing External", "model_qualifier": "FS 15/23", "winter_efficiency_pct": 87.4, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 56.2, "output_kw_max": 21.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010411", "000050", "0", "2006/Jul/28 13:42", "Heating World Group", "Heating World Group", "Grandee Combi Condensing External", "FS 15/23", "", "2005", "current", "4", "2", "2", "2", "0", "", "", "2", "3", "1", "15", "21", "", "", "87.4", "80.0", "", "56.2", "", "2", "", "", "202", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.4", "93.3", "", "", "", "", "92.8"]} +{"pcdb_id": 10412, "brand_name": "Heating World Group", "model_name": "Grandee System Condensing External", "model_qualifier": "FS 15/23", "winter_efficiency_pct": 87.4, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 21.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010412", "000050", "0", "2012/Mar/27 10:12", "Heating World Group", "Heating World Group", "Grandee System Condensing External", "FS 15/23", "", "2005", "current", "4", "2", "1", "1", "0", "", "", "2", "3", "1", "15", "21", "", "", "87.4", "79.6", "", "58.1", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.4", "93.3", "", "", "", "", "92.8"]} +{"pcdb_id": 10413, "brand_name": "Heating World Group", "model_name": "Grandee Standard Condensing External", "model_qualifier": "FS 15/23", "winter_efficiency_pct": 87.4, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 21.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010413", "000050", "0", "2012/Mar/27 10:12", "Heating World Group", "Heating World Group", "Grandee Standard Condensing External", "FS 15/23", "", "2005", "current", "4", "2", "2", "1", "0", "", "", "2", "3", "1", "15", "21", "", "", "87.4", "79.6", "", "58.1", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.4", "93.3", "", "", "", "", "92.8"]} +{"pcdb_id": 10414, "brand_name": "Heating World Group", "model_name": "Grandee Combi Condensing", "model_qualifier": "FS 15/23", "winter_efficiency_pct": 87.4, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 56.2, "output_kw_max": 21.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010414", "000050", "0", "2006/Jul/28 13:43", "Heating World Group", "Heating World Group", "Grandee Combi Condensing", "FS 15/23", "", "2005", "current", "4", "2", "1", "2", "0", "", "", "2", "3", "1", "15", "21", "", "", "87.4", "80.0", "", "56.2", "", "2", "", "", "202", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.4", "93.3", "", "", "", "", "92.8"]} +{"pcdb_id": 10415, "brand_name": "Heating World Group", "model_name": "Grandee System Condensing", "model_qualifier": "FS 15/23", "winter_efficiency_pct": 87.4, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 22.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010415", "000050", "0", "2012/Mar/27 10:12", "Heating World Group", "Heating World Group", "Grandee System Condensing", "FS 15/23", "", "2005", "current", "4", "2", "1", "1", "0", "", "", "2", "3", "1", "15", "22", "", "", "87.4", "79.6", "", "58.1", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.4", "93.3", "", "", "", "", "92.8"]} +{"pcdb_id": 10416, "brand_name": "Heating World Group", "model_name": "Grandee Standard Condensing", "model_qualifier": "FS 15/23", "winter_efficiency_pct": 87.4, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 21.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010416", "000050", "0", "2012/Mar/27 10:12", "Heating World Group", "Heating World Group", "Grandee Standard Condensing", "FS 15/23", "", "2005", "current", "4", "2", "1", "1", "0", "", "", "2", "3", "1", "15", "21", "", "", "87.4", "79.6", "", "58.1", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.4", "93.3", "", "", "", "", "92.8"]} +{"pcdb_id": 10417, "brand_name": "Heating World Group", "model_name": "Grandee Combi Condensing External", "model_qualifier": "FS 23/30", "winter_efficiency_pct": 87.0, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 56.0, "output_kw_max": 26.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010417", "000050", "0", "2006/Jul/28 13:44", "Heating World Group", "Heating World Group", "Grandee Combi Condensing External", "FS 23/30", "", "2005", "current", "4", "2", "2", "2", "0", "", "", "2", "3", "1", "23", "26", "", "", "87.0", "79.6", "", "56.0", "", "2", "", "", "202", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.1", "92.6", "", "", "", "", "92.1"]} +{"pcdb_id": 10418, "brand_name": "Heating World Group", "model_name": "Grandee System Condensing External", "model_qualifier": "FS 23/30", "winter_efficiency_pct": 87.0, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 26.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010418", "000050", "0", "2012/Mar/27 10:12", "Heating World Group", "Heating World Group", "Grandee System Condensing External", "FS 23/30", "", "2005", "current", "4", "2", "2", "1", "0", "", "", "2", "3", "1", "23", "26", "", "", "87.0", "79.2", "", "57.9", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.1", "92.6", "", "", "", "", "92.1"]} +{"pcdb_id": 10419, "brand_name": "Heating World Group", "model_name": "Grandee Standard Condensing External", "model_qualifier": "FS 23/30", "winter_efficiency_pct": 87.0, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 26.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010419", "000050", "0", "2012/Mar/27 10:12", "Heating World Group", "Heating World Group", "Grandee Standard Condensing External", "FS 23/30", "", "2005", "current", "4", "2", "2", "1", "0", "", "", "2", "3", "1", "23", "26", "", "", "87.0", "79.2", "", "57.9", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.1", "92.6", "", "", "", "", "92.1"]} +{"pcdb_id": 10420, "brand_name": "Heating World Group", "model_name": "Grandee Combi Condensing", "model_qualifier": "FS 23/30", "winter_efficiency_pct": 87.0, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 56.0, "output_kw_max": 26.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010420", "000050", "0", "2006/Jul/28 13:44", "Heating World Group", "Heating World Group", "Grandee Combi Condensing", "FS 23/30", "", "2005", "current", "4", "2", "1", "2", "0", "", "", "2", "3", "1", "23", "26", "", "", "87.0", "79.6", "", "56.0", "", "2", "", "", "202", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.1", "92.6", "", "", "", "", "92.1"]} +{"pcdb_id": 10421, "brand_name": "Heating World Group", "model_name": "Grandee System Condensing", "model_qualifier": "FS 23/30", "winter_efficiency_pct": 87.0, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 26.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010421", "000050", "0", "2012/Mar/27 10:12", "Heating World Group", "Heating World Group", "Grandee System Condensing", "FS 23/30", "", "2005", "current", "4", "2", "1", "1", "0", "", "", "2", "3", "1", "23", "26", "", "", "87.0", "79.2", "", "57.9", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.1", "92.6", "", "", "", "", "92.1"]} +{"pcdb_id": 10422, "brand_name": "Heating World Group", "model_name": "Grandee Standard Condensing", "model_qualifier": "FS 23/30", "winter_efficiency_pct": 87.0, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 26.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010422", "000050", "0", "2012/Mar/27 10:12", "Heating World Group", "Heating World Group", "Grandee Standard Condensing", "FS 23/30", "", "2005", "current", "4", "2", "1", "1", "0", "", "", "2", "3", "1", "23", "26", "", "", "87.0", "79.2", "", "57.9", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.1", "92.6", "", "", "", "", "92.1"]} +{"pcdb_id": 10423, "brand_name": "Optia", "model_name": "HE 18", "model_qualifier": "", "winter_efficiency_pct": 85.0, "summer_efficiency_pct": 77.4, "comparative_hot_water_efficiency_pct": 56.6, "output_kw_max": 18.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010423", "000008", "0", "2012/Mar/27 10:12", "Ideal Boilers", "Optia", "HE 18", "", "GC No. 41 421 96", "2005", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18", "18.0", "", "", "85.0", "77.4", "", "56.6", "", "2", "", "", "101", "1", "1", "100", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "86.6", "93.4", "", "", "", "", "92.1"]} +{"pcdb_id": 10424, "brand_name": "Optia", "model_name": "HE 15", "model_qualifier": "", "winter_efficiency_pct": 84.3, "summer_efficiency_pct": 76.7, "comparative_hot_water_efficiency_pct": 56.0, "output_kw_max": 15.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010424", "000008", "0", "2012/Mar/27 10:12", "Ideal Boilers", "Optia", "HE 15", "", "GC No. 41 421 72", "2005", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "15", "15.0", "", "", "84.3", "76.7", "", "56.0", "", "2", "", "", "101", "1", "1", "100", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "85.6", "92.3", "", "", "", "", "91.0"]} +{"pcdb_id": 10425, "brand_name": "Optia", "model_name": "HE 12", "model_qualifier": "", "winter_efficiency_pct": 85.0, "summer_efficiency_pct": 77.4, "comparative_hot_water_efficiency_pct": 56.6, "output_kw_max": 12.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010425", "000008", "0", "2012/Mar/27 10:12", "Ideal Boilers", "Optia", "HE 12", "", "GC No. 41 421 71", "2005", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "12", "12.0", "", "", "85.0", "77.4", "", "56.6", "", "2", "", "", "101", "1", "1", "100", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "85.8", "94.0", "", "", "", "", "92.4"]} +{"pcdb_id": 10426, "brand_name": "Optia", "model_name": "HE 9", "model_qualifier": "", "winter_efficiency_pct": 84.8, "summer_efficiency_pct": 77.2, "comparative_hot_water_efficiency_pct": 56.4, "output_kw_max": 9.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010426", "000008", "0", "2012/Mar/27 10:12", "Ideal Boilers", "Optia", "HE 9", "", "GC No. 41 421 70", "2005", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "9.0", "9.0", "", "", "84.8", "77.2", "", "56.4", "", "2", "", "", "101", "1", "1", "100", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "85.7", "93.4", "", "", "", "", "92.0"]} +{"pcdb_id": 10427, "brand_name": "Ideal", "model_name": "Classic", "model_qualifier": "HE 9", "winter_efficiency_pct": 84.8, "summer_efficiency_pct": 77.2, "comparative_hot_water_efficiency_pct": 56.4, "output_kw_max": 9.0, "final_year_of_manufacture": 2011, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010427", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "Classic", "HE 9", "41-415-58", "2005", "2011", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "9", "9.0", "", "", "84.8", "77.2", "", "56.4", "", "2", "", "", "101", "1", "1", "100", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "85.7", "93.4", "", "", "", "", "92.0"]} +{"pcdb_id": 10428, "brand_name": "Ideal", "model_name": "Classic", "model_qualifier": "HE 12", "winter_efficiency_pct": 85.0, "summer_efficiency_pct": 77.4, "comparative_hot_water_efficiency_pct": 56.6, "output_kw_max": 12.0, "final_year_of_manufacture": 2011, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010428", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "Classic", "HE 12", "41-415-59", "2005", "2011", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "12", "12.0", "", "", "85.0", "77.4", "", "56.6", "", "2", "", "", "101", "1", "1", "100", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "85.8", "94.0", "", "", "", "", "92.4"]} +{"pcdb_id": 10429, "brand_name": "Ideal", "model_name": "Classic", "model_qualifier": "HE 15", "winter_efficiency_pct": 84.3, "summer_efficiency_pct": 76.7, "comparative_hot_water_efficiency_pct": 56.0, "output_kw_max": 15.0, "final_year_of_manufacture": 2011, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010429", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "Classic", "HE 15", "41-421-45", "2005", "2011", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "15", "15.0", "", "", "84.3", "76.7", "", "56.0", "", "2", "", "", "101", "1", "1", "100", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "85.6", "92.3", "", "", "", "", "91.0"]} +{"pcdb_id": 10430, "brand_name": "Ideal", "model_name": "Classic", "model_qualifier": "HE 18", "winter_efficiency_pct": 85.0, "summer_efficiency_pct": 77.4, "comparative_hot_water_efficiency_pct": 56.6, "output_kw_max": 18.0, "final_year_of_manufacture": 2011, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010430", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "Classic", "HE 18", "41-421-46", "2005", "2011", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18", "18.0", "", "", "85.0", "77.4", "", "56.6", "", "2", "", "", "101", "1", "1", "100", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "86.6", "93.4", "", "", "", "", "92.1"]} +{"pcdb_id": 10432, "brand_name": "Ferroli", "model_name": "Domicompact", "model_qualifier": "F 30 B", "winter_efficiency_pct": 86.2, "summer_efficiency_pct": 77.6, "comparative_hot_water_efficiency_pct": 54.6, "output_kw_max": 30.0, "final_year_of_manufacture": 2017, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010432", "000097", "0", "2017/Aug/07 17:00", "Ferroli SpA", "Ferroli", "Domicompact", "F 30 B", "", "2005", "2017", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "30", "30", "", "", "86.2", "77.6", "", "54.6", "", "2", "", "", "104", "1", "2", "170", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "86.9", "92.7", "", "", "", "", "91.6"]} +{"pcdb_id": 10433, "brand_name": "Ferroli", "model_name": "Domicompact", "model_qualifier": "F 24 B", "winter_efficiency_pct": 86.2, "summer_efficiency_pct": 77.6, "comparative_hot_water_efficiency_pct": 54.6, "output_kw_max": 24.1, "final_year_of_manufacture": 2017, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010433", "000097", "0", "2017/Aug/07 17:01", "Ferroli SpA", "Ferroli", "Domicompact", "F 24 B", "", "2005", "2017", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.1", "24.1", "", "", "86.2", "77.6", "", "54.6", "", "2", "", "", "104", "1", "2", "135", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "86.9", "92.7", "", "", "", "", "91.6"]} +{"pcdb_id": 10434, "brand_name": "Ferroli", "model_name": "F 30 B", "model_qualifier": "", "winter_efficiency_pct": 86.2, "summer_efficiency_pct": 77.6, "comparative_hot_water_efficiency_pct": 54.6, "output_kw_max": 30.0, "final_year_of_manufacture": 2008, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010434", "000097", "0", "2009/Apr/28 16:09", "Ferroli SpA", "Ferroli", "F 30 B", "", "", "2005", "2008", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "30.0", "30.0", "", "", "86.2", "77.6", "", "54.6", "", "2", "", "", "104", "1", "2", "135", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "", "", "0005", "", "", "", "", "", "", "", "", "86.9", "92.7", "", "", "", "", "91.6"]} +{"pcdb_id": 10435, "brand_name": "Ferroli", "model_name": "F 24 B", "model_qualifier": "", "winter_efficiency_pct": 86.2, "summer_efficiency_pct": 77.6, "comparative_hot_water_efficiency_pct": 54.6, "output_kw_max": 24.1, "final_year_of_manufacture": 2008, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010435", "000097", "0", "2009/Apr/28 16:07", "Ferroli SpA", "Ferroli", "F 24 B", "", "", "2005", "2008", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.1", "24.1", "", "", "86.2", "77.6", "", "54.6", "", "2", "", "", "104", "1", "2", "135", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "", "", "0005", "", "", "", "", "", "", "", "", "86.9", "92.7", "", "", "", "", "91.6"]} +{"pcdb_id": 10436, "brand_name": "Ferroli", "model_name": "Domicompact", "model_qualifier": "F 30 B LPG", "winter_efficiency_pct": 87.2, "summer_efficiency_pct": 78.6, "comparative_hot_water_efficiency_pct": 55.3, "output_kw_max": 30.0, "final_year_of_manufacture": 2017, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010436", "000097", "0", "2017/Aug/21 13:43", "Ferroli SpA", "Ferroli", "Domicompact", "F 30 B LPG", "", "2005", "2017", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "30", "30", "", "", "87.2", "78.6", "", "55.3", "", "2", "1", "", "104", "1", "2", "170", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.9", "94.8", "", "", "", "", "93.7"]} +{"pcdb_id": 10437, "brand_name": "Ferroli", "model_name": "Domicompact", "model_qualifier": "F 24 B LPG", "winter_efficiency_pct": 87.2, "summer_efficiency_pct": 78.6, "comparative_hot_water_efficiency_pct": 55.3, "output_kw_max": 24.1, "final_year_of_manufacture": 2017, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010437", "000097", "0", "2017/Aug/21 13:46", "Ferroli SpA", "Ferroli", "Domicompact", "F 24 B LPG", "", "2005", "2017", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24.1", "24.1", "", "", "87.2", "78.6", "", "55.3", "", "2", "1", "", "104", "1", "2", "135", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.9", "94.8", "", "", "", "", "93.7"]} +{"pcdb_id": 10438, "brand_name": "Ferroli", "model_name": "F 30 B LPG", "model_qualifier": "", "winter_efficiency_pct": 87.2, "summer_efficiency_pct": 78.6, "comparative_hot_water_efficiency_pct": 55.3, "output_kw_max": 30.0, "final_year_of_manufacture": 2008, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010438", "000097", "0", "2009/Apr/28 16:09", "Ferroli SpA", "Ferroli", "F 30 B LPG", "", "", "2005", "2008", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "30.0", "30.0", "", "", "87.2", "78.6", "", "55.3", "", "2", "1", "", "104", "1", "2", "135", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "", "", "0005", "", "", "", "", "", "", "", "", "88.9", "94.8", "", "", "", "", "93.7"]} +{"pcdb_id": 10439, "brand_name": "Ferroli", "model_name": "F 24 B LPG", "model_qualifier": "", "winter_efficiency_pct": 87.2, "summer_efficiency_pct": 78.6, "comparative_hot_water_efficiency_pct": 55.3, "output_kw_max": 24.1, "final_year_of_manufacture": 2008, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010439", "000097", "0", "2009/Apr/28 16:11", "Ferroli SpA", "Ferroli", "F 24 B LPG", "", "", "2005", "2008", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24.1", "24.1", "", "", "87.2", "78.6", "", "55.3", "", "2", "1", "", "104", "1", "2", "135", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "", "", "0005", "", "", "", "", "", "", "", "", "88.9", "94.8", "", "", "", "", "93.7"]} +{"pcdb_id": 10440, "brand_name": "Radiant", "model_name": "B-Condense", "model_qualifier": "RHA 28/100", "winter_efficiency_pct": 85.2, "summer_efficiency_pct": 78.5, "comparative_hot_water_efficiency_pct": 35.4, "output_kw_max": 27.47, "final_year_of_manufacture": 2007, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010440", "000088", "0", "2024/Jan/31 10:17", "Radiant Bruciatori SpA", "Radiant", "B-Condense", "RHA 28/100", "", "2005", "2007", "1", "1", "1", "2", "0", "", "", "2", "2", "2", "27.47", "27.47", "", "", "85.2", "78.5", "", "35.4", "", "2", "", "", "106", "1", "2", "165", "", "2", "2", "0", "105", "0", "15", "2", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "85.8", "90.8", "", "", "", "", "89.9"]} +{"pcdb_id": 10441, "brand_name": "Radiant", "model_name": "B-Condense", "model_qualifier": "RHA 28", "winter_efficiency_pct": 85.2, "summer_efficiency_pct": 78.0, "comparative_hot_water_efficiency_pct": 45.3, "output_kw_max": 27.47, "final_year_of_manufacture": 2007, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010441", "000088", "0", "2024/Jan/31 10:17", "Radiant Bruciatori SpA", "Radiant", "B-Condense", "RHA 28", "", "2005", "2007", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "27.47", "27.47", "", "", "85.2", "78.0", "", "45.3", "", "2", "", "", "106", "1", "2", "165", "", "2", "2", "0", "18.3", "0", "15", "2", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "85.8", "90.8", "", "", "", "", "89.9"]} +{"pcdb_id": 10442, "brand_name": "Ideal", "model_name": "icos System", "model_qualifier": "HE 15", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 14.6, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010442", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "icos System", "HE 15", "41 421 99", "2005", "2001", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "14.6", "14.6", "", "", "89.0", "80.0", "", "58.4", "", "2", "", "", "102", "1", "2", "38", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.5", "99.0", "", "", "", "", "97.0"]} +{"pcdb_id": 10443, "brand_name": "Main", "model_name": "Combi", "model_qualifier": "24", "winter_efficiency_pct": 79.5, "summer_efficiency_pct": 69.4, "comparative_hot_water_efficiency_pct": 48.8, "output_kw_max": 24.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010443", "000005", "0", "2006/Jan/17 12:31", "Baxi Potterton", "Main", "Combi", "24", "GC No. 47-474-01", "2005", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "24", "24", "", "", "79.5", "69.4", "", "48.8", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.2", "79.2", "", "", "", "", "79.8"]} +{"pcdb_id": 10444, "brand_name": "Main", "model_name": "Combi", "model_qualifier": "24 HE", "winter_efficiency_pct": 85.8, "summer_efficiency_pct": 77.2, "comparative_hot_water_efficiency_pct": 54.3, "output_kw_max": 24.0, "final_year_of_manufacture": 2012, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010444", "000005", "0", "2013/May/07 10:29", "Baxi Potterton", "Main", "Combi", "24 HE", "GC No. 47-474-02", "2005", "2012", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "85.8", "77.2", "", "54.3", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.2", "91.5", "", "", "", "", "90.7"]} +{"pcdb_id": 10445, "brand_name": "Potterton", "model_name": "Gold", "model_qualifier": "24 HE", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 55.8, "output_kw_max": 24.0, "final_year_of_manufacture": 2008, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010445", "000005", "0", "2010/Nov/19 09:18", "Baxi Potterton", "Potterton", "Gold", "24 HE", "GC No. 47-590-05", "2005", "2008", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "88.0", "79.4", "", "55.8", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "96.9", "", "", "", "", "95.2"]} +{"pcdb_id": 10446, "brand_name": "Baxi", "model_name": "Platinum", "model_qualifier": "24 HE", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 55.8, "output_kw_max": 24.0, "final_year_of_manufacture": 2007, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010446", "000005", "0", "2010/Nov/19 09:02", "Baxi Potterton", "Baxi", "Platinum", "24 HE", "GC No. 47-075-20", "2005", "2007", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "88.0", "79.4", "", "55.8", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "96.9", "", "", "", "", "95.2"]} +{"pcdb_id": 10447, "brand_name": "Glow-worm", "model_name": "Xtramax HE", "model_qualifier": "", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 81.9, "comparative_hot_water_efficiency_pct": 44.0, "output_kw_max": 28.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010447", "000207", "0", "2024/Jan/31 10:17", "Vaillant Group", "Glow-worm", "Xtramax HE", "", "", "2005", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "28", "28", "", "", "89.2", "81.9", "", "44.0", "", "2", "1", "", "106", "1", "2", "241", "8", "2", "1", "0", "42", "0", "15", "2", "50", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.1", "99.4", "", "", "", "", "97.6"]} +{"pcdb_id": 10448, "brand_name": "Glow-worm", "model_name": "Xtramax HE", "model_qualifier": "", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 80.9, "comparative_hot_water_efficiency_pct": 43.5, "output_kw_max": 28.0, "final_year_of_manufacture": 2013, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010448", "000207", "0", "2024/Jan/31 10:17", "Vaillant Group", "Glow-worm", "Xtramax HE", "", "GC 47-047-29", "2005", "2013", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28", "28", "", "", "88.2", "80.9", "", "43.5", "", "2", "", "", "106", "1", "2", "241", "8", "2", "1", "0", "42", "0", "15", "2", "50", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.1", "97.2", "", "", "", "", "95.5"]} +{"pcdb_id": 10449, "brand_name": "Saunier Duval", "model_name": "SD Isotwin Condens F35 E", "model_qualifier": "", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 81.9, "comparative_hot_water_efficiency_pct": 44.0, "output_kw_max": 28.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010449", "000206", "0", "2024/Jan/31 10:17", "Vaillant Group", "Saunier Duval", "SD Isotwin Condens F35 E", "", "", "2005", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "28", "28", "", "", "89.2", "81.9", "", "44.0", "", "2", "1", "", "106", "1", "2", "241", "8", "2", "1", "0", "42", "0", "15", "2", "50", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.1", "99.4", "", "", "", "", "97.6"]} +{"pcdb_id": 10450, "brand_name": "Saunier Duval", "model_name": "SD Isotwin Condens F35 E", "model_qualifier": "", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 80.9, "comparative_hot_water_efficiency_pct": 43.5, "output_kw_max": 28.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010450", "000206", "0", "2024/Jan/31 10:17", "Vaillant Group", "Saunier Duval", "SD Isotwin Condens F35 E", "", "GC 47-920-47", "2005", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28", "28", "", "", "88.2", "80.9", "", "43.5", "", "2", "", "", "106", "1", "2", "241", "8", "2", "1", "0", "42", "0", "15", "2", "50", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.1", "97.2", "", "", "", "", "95.5"]} +{"pcdb_id": 10451, "brand_name": "British Gas", "model_name": "537/I", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 56.4, "output_kw_max": 30.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010451", "000035", "0", "2006/Jan/17 12:31", "Worcester Bosch Group", "British Gas", "537/I", "", "47-406-04", "2005", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "30.0", "30.0", "", "", "88.8", "80.2", "", "56.4", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.1", "98.8", "", "", "", "", "96.8"]} +{"pcdb_id": 10452, "brand_name": "British Gas", "model_name": "537/I", "model_qualifier": "", "winter_efficiency_pct": 89.8, "summer_efficiency_pct": 81.2, "comparative_hot_water_efficiency_pct": 57.1, "output_kw_max": 30.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010452", "000035", "0", "2006/Jan/17 12:31", "Worcester Bosch Group", "British Gas", "537/I", "", "47-406-05", "2005", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "30.0", "30.0", "", "", "89.8", "81.2", "", "57.1", "", "2", "1", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.1", "101.0", "", "", "", "", "99.0"]} +{"pcdb_id": 10453, "brand_name": "British Gas", "model_name": "542/I", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 56.4, "output_kw_max": 30.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010453", "000035", "0", "2006/Jan/17 12:31", "Worcester Bosch Group", "British Gas", "542/I", "", "47-406-06", "2005", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "30.0", "30.0", "", "", "88.8", "80.2", "", "56.4", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.1", "98.8", "", "", "", "", "96.8"]} +{"pcdb_id": 10454, "brand_name": "British Gas", "model_name": "542/I", "model_qualifier": "", "winter_efficiency_pct": 89.8, "summer_efficiency_pct": 81.2, "comparative_hot_water_efficiency_pct": 57.1, "output_kw_max": 30.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010454", "000035", "0", "2006/Jan/17 12:31", "Worcester Bosch Group", "British Gas", "542/I", "", "47-406-07", "2005", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "30.0", "30.0", "", "", "89.8", "81.2", "", "57.1", "", "2", "1", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.1", "101.0", "", "", "", "", "99.0"]} +{"pcdb_id": 10455, "brand_name": "British Gas", "model_name": "430/I", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 30.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010455", "000035", "0", "2012/Mar/27 10:12", "Worcester Bosch Group", "British Gas", "430/I", "", "41-311-80", "2005", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "30.0", "30.0", "", "", "88.8", "79.8", "", "58.3", "", "2", "", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.1", "98.8", "", "", "", "", "96.8"]} +{"pcdb_id": 10456, "brand_name": "British Gas", "model_name": "430/I", "model_qualifier": "", "winter_efficiency_pct": 89.8, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 59.1, "output_kw_max": 30.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010456", "000035", "0", "2012/Mar/27 10:12", "Worcester Bosch Group", "British Gas", "430/I", "", "41-311-81", "2005", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "30.0", "30.0", "", "", "89.8", "80.8", "", "59.1", "", "2", "1", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.1", "101.0", "", "", "", "", "99.0"]} +{"pcdb_id": 10457, "brand_name": "British Gas", "model_name": "532/I", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 56.4, "output_kw_max": 30.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010457", "000035", "0", "2006/Jan/17 12:31", "Worcester Bosch Group", "British Gas", "532/I", "", "47-406-02", "2005", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "30.0", "30.0", "", "", "88.8", "80.2", "", "56.4", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.1", "98.8", "", "", "", "", "96.8"]} +{"pcdb_id": 10458, "brand_name": "British Gas", "model_name": "532/I", "model_qualifier": "", "winter_efficiency_pct": 89.8, "summer_efficiency_pct": 81.2, "comparative_hot_water_efficiency_pct": 57.1, "output_kw_max": 30.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010458", "000035", "0", "2006/Jan/17 12:31", "Worcester Bosch Group", "British Gas", "532/I", "", "47-406-03", "2005", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "30.0", "30.0", "", "", "89.8", "81.2", "", "57.1", "", "2", "1", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.1", "101.0", "", "", "", "", "99.0"]} +{"pcdb_id": 10459, "brand_name": "Worcester", "model_name": "Greenstar Cdi", "model_qualifier": "30 Cdi System", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 30.0, "final_year_of_manufacture": 2014, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010459", "000035", "0", "2020/Sep/08 09:25", "Worcester Bosch Group", "Worcester", "Greenstar Cdi", "30 Cdi System", "41-311-93", "2005", "2014", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "30.0", "30.0", "", "", "88.8", "79.8", "", "58.3", "", "2", "", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.1", "98.8", "", "", "", "", "96.8"]} +{"pcdb_id": 10460, "brand_name": "Worcester", "model_name": "Greenstar Cdi", "model_qualifier": "30 Cdi System", "winter_efficiency_pct": 89.8, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 59.1, "output_kw_max": 30.0, "final_year_of_manufacture": 2014, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010460", "000035", "0", "2020/Sep/08 09:25", "Worcester Bosch Group", "Worcester", "Greenstar Cdi", "30 Cdi System", "41-311-97", "2005", "2014", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "30.0", "30.0", "", "", "89.8", "80.8", "", "59.1", "", "2", "1", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.1", "101.0", "", "", "", "", "99.0"]} +{"pcdb_id": 10461, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "18Ri", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 18.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010461", "000035", "0", "2020/Sep/08 09:25", "Worcester Bosch Group", "Worcester", "Greenstar", "18Ri", "41-311-78", "2005", "2015", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "18.00", "18.00", "", "", "89.1", "80.1", "", "58.5", "", "2", "1", "", "102", "1", "2", "50", "5", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.7", "99.2", "", "", "", "", "97.4"]} +{"pcdb_id": 10462, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "18Ri", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 18.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010462", "000035", "0", "2020/Sep/08 09:25", "Worcester Bosch Group", "Worcester", "Greenstar", "18Ri", "41-311-77", "2005", "2015", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18.00", "18.00", "", "", "88.1", "79.1", "", "57.7", "", "2", "", "", "102", "1", "2", "50", "5", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "97.0", "", "", "", "", "95.3"]} +{"pcdb_id": 10463, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "15Ri", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 15.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010463", "000035", "0", "2020/Sep/08 09:25", "Worcester Bosch Group", "Worcester", "Greenstar", "15Ri", "41-311-76", "2005", "2015", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "15.00", "15.00", "", "", "89.1", "80.1", "", "58.5", "", "2", "1", "", "102", "1", "2", "50", "5", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.7", "99.2", "", "", "", "", "97.4"]} +{"pcdb_id": 10464, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "15Ri", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 15.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010464", "000035", "0", "2020/Sep/08 09:25", "Worcester Bosch Group", "Worcester", "Greenstar", "15Ri", "41-311-75", "2005", "2015", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "15.00", "15.00", "", "", "88.1", "79.1", "", "57.7", "", "2", "", "", "102", "1", "2", "50", "5", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "97.0", "", "", "", "", "95.3"]} +{"pcdb_id": 10465, "brand_name": "ACV", "model_name": "HeatMaster 35TC", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 81.4, "comparative_hot_water_efficiency_pct": 39.3, "output_kw_max": 34.1, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 1, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010465", "000243", "0", "2024/Jan/31 10:17", "ACV International", "ACV", "HeatMaster 35TC", "", "05620001", "2005", "current", "1", "1", "1", "2", "0", "", "", "2", "2", "2", "34.1", "34.1", "", "", "88.4", "81.4", "", "39.3", "", "2", "", "", "106", "1", "2", "300", "", "1", "2", "0", "189", "0", "50", "2", "80", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.2", "97.8", "", "", "", "", "95.9"]} +{"pcdb_id": 10466, "brand_name": "ACV", "model_name": "Prestige 32 Excellence", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 81.3, "comparative_hot_water_efficiency_pct": 40.4, "output_kw_max": 31.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010466", "000243", "0", "2024/Jan/31 10:17", "ACV International", "ACV", "Prestige 32 Excellence", "", "05617601", "2003", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "31.0", "31.0", "", "", "88.6", "81.3", "", "40.4", "", "2", "", "", "106", "1", "2", "300", "", "2", "1", "0", "70", "0", "15", "2", "80", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.2", "98.2", "", "", "", "", "96.3"]} +{"pcdb_id": 10467, "brand_name": "ACV", "model_name": "Prestige 24 Excellence", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 81.3, "comparative_hot_water_efficiency_pct": 40.4, "output_kw_max": 23.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010467", "000243", "0", "2024/Jan/31 10:17", "ACV International", "ACV", "Prestige 24 Excellence", "", "05617501", "2003", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "23.4", "23.4", "", "", "88.6", "81.3", "", "40.4", "", "2", "", "", "106", "1", "2", "300", "", "2", "1", "0", "70", "0", "15", "2", "80", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.2", "98.2", "", "", "", "", "96.3"]} +{"pcdb_id": 10468, "brand_name": "ACV", "model_name": "Prestige 75 Solo", "model_qualifier": "", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 69.9, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010468", "000243", "0", "2012/Mar/27 10:12", "ACV International", "ACV", "Prestige 75 Solo", "", "05619601", "2005", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "69.9", "69.9", "", "", "88.2", "79.2", "", "57.8", "", "2", "", "", "102", "1", "2", "200", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.2", "97.1", "", "", "", "", "95.4"]} +{"pcdb_id": 10469, "brand_name": "ACV", "model_name": "Prestige 50 Solo", "model_qualifier": "", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 48.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010469", "000243", "0", "2012/Mar/27 10:12", "ACV International", "ACV", "Prestige 50 Solo", "", "05610501", "2005", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "48.4", "48.4", "", "", "88.2", "79.2", "", "57.8", "", "2", "", "", "102", "1", "2", "200", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.2", "97.1", "", "", "", "", "95.4"]} +{"pcdb_id": 10470, "brand_name": "ACV", "model_name": "Prestige 32 Solo", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 31.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010470", "000243", "0", "2012/Mar/27 10:12", "ACV International", "ACV", "Prestige 32 Solo", "", "05605601", "2003", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "31.0", "31.0", "", "", "88.6", "79.6", "", "58.1", "", "2", "", "", "102", "1", "2", "200", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.2", "98.2", "", "", "", "", "96.3"]} +{"pcdb_id": 10471, "brand_name": "ACV", "model_name": "Prestige 24 Solo", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 23.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010471", "000243", "0", "2012/Mar/27 10:12", "ACV International", "ACV", "Prestige 24 Solo", "", "05605501", "2003", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "23.4", "23.4", "", "", "88.6", "79.6", "", "58.1", "", "2", "", "", "102", "1", "2", "200", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.2", "98.2", "", "", "", "", "96.3"]} +{"pcdb_id": 10472, "brand_name": "British Gas", "model_name": "537", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 56.4, "output_kw_max": 30.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010472", "000035", "0", "2006/Jan/17 12:31", "Worcester Bosch Group", "British Gas", "537", "", "", "2005", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "30.0", "30.0", "", "", "88.8", "80.2", "", "56.4", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.1", "98.8", "", "", "", "", "96.8"]} +{"pcdb_id": 10473, "brand_name": "British Gas", "model_name": "537 LPG", "model_qualifier": "", "winter_efficiency_pct": 89.8, "summer_efficiency_pct": 81.2, "comparative_hot_water_efficiency_pct": 57.1, "output_kw_max": 30.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010473", "000035", "0", "2006/Jan/17 12:31", "Worcester Bosch Group", "British Gas", "537 LPG", "", "", "2005", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "30.0", "30.0", "", "", "89.8", "81.2", "", "57.1", "", "2", "1", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.1", "101.0", "", "", "", "", "99.0"]} +{"pcdb_id": 10474, "brand_name": "British Gas", "model_name": "542", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 56.4, "output_kw_max": 30.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010474", "000035", "0", "2005/Oct/30 20:07", "Worcester Bosch Group", "British Gas", "542", "", "", "2005", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "30", "30", "", "", "88.8", "80.2", "", "56.4", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.1", "98.8", "", "", "", "", "96.8"]} +{"pcdb_id": 10475, "brand_name": "British Gas", "model_name": "542 LPG", "model_qualifier": "", "winter_efficiency_pct": 89.8, "summer_efficiency_pct": 81.2, "comparative_hot_water_efficiency_pct": 57.1, "output_kw_max": 30.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010475", "000035", "0", "2005/Oct/30 20:12", "Worcester Bosch Group", "British Gas", "542 LPG", "", "", "2005", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "30", "30", "", "", "89.8", "81.2", "", "57.1", "", "2", "1", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.1", "101.0", "", "", "", "", "99.0"]} +{"pcdb_id": 10476, "brand_name": "British Gas", "model_name": "532", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 56.4, "output_kw_max": 30.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010476", "000035", "0", "2005/Oct/30 20:07", "Worcester Bosch Group", "British Gas", "532", "", "", "2005", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "30", "30", "", "", "88.8", "80.2", "", "56.4", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.1", "98.8", "", "", "", "", "96.8"]} +{"pcdb_id": 10477, "brand_name": "British Gas", "model_name": "532 LPG", "model_qualifier": "", "winter_efficiency_pct": 89.8, "summer_efficiency_pct": 81.2, "comparative_hot_water_efficiency_pct": 57.1, "output_kw_max": 30.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010477", "000035", "0", "2005/Oct/30 20:11", "Worcester Bosch Group", "British Gas", "532 LPG", "", "", "2005", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "30", "30", "", "", "89.8", "81.2", "", "57.1", "", "2", "1", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.1", "101.0", "", "", "", "", "99.0"]} +{"pcdb_id": 10478, "brand_name": "British Gas", "model_name": "430", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 30.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010478", "000035", "0", "2012/Mar/27 10:12", "Worcester Bosch Group", "British Gas", "430", "", "", "2005", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "30", "30", "", "", "88.8", "79.8", "", "58.3", "", "2", "", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.1", "98.8", "", "", "", "", "96.8"]} +{"pcdb_id": 10479, "brand_name": "British Gas", "model_name": "430 LPG", "model_qualifier": "", "winter_efficiency_pct": 89.8, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 59.1, "output_kw_max": 30.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010479", "000035", "0", "2012/Mar/27 10:12", "Worcester Bosch Group", "British Gas", "430 LPG", "", "", "2005", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "30", "30", "", "", "89.8", "80.8", "", "59.1", "", "2", "1", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.1", "101.0", "", "", "", "", "99.0"]} +{"pcdb_id": 10480, "brand_name": "Wolf", "model_name": "CGB-50", "model_qualifier": "", "winter_efficiency_pct": 89.5, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 58.8, "output_kw_max": 49.9, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010480", "000240", "0", "2012/Mar/27 10:12", "Wolf", "Wolf", "CGB-50", "", "8611570", "2005", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "49.9", "49.9", "", "", "89.5", "80.5", "", "58.8", "", "2", "1", "", "102", "1", "2", "84", "6", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.2", "100.1", "", "", "", "", "98.2"]} +{"pcdb_id": 10481, "brand_name": "Wolf", "model_name": "CGB-50", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 49.9, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010481", "000240", "0", "2012/Mar/27 10:12", "Wolf", "Wolf", "CGB-50", "", "8611568", "2005", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "49.9", "49.9", "", "", "88.5", "79.5", "", "58.1", "", "2", "", "", "102", "1", "2", "84", "6", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.2", "97.9", "", "", "", "", "96.1"]} +{"pcdb_id": 10482, "brand_name": "Wolf", "model_name": "CGB-35", "model_qualifier": "", "winter_efficiency_pct": 89.6, "summer_efficiency_pct": 80.6, "comparative_hot_water_efficiency_pct": 58.9, "output_kw_max": 34.9, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010482", "000240", "0", "2012/Mar/27 10:12", "Wolf", "Wolf", "CGB-35", "", "8611569", "2005", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "34.9", "34.9", "", "", "89.6", "80.6", "", "58.9", "", "2", "1", "", "102", "1", "2", "54", "6", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.3", "100.3", "", "", "", "", "98.4"]} +{"pcdb_id": 10483, "brand_name": "Wolf", "model_name": "CGB-35", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 34.9, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010483", "000240", "0", "2012/Mar/27 10:12", "Wolf", "Wolf", "CGB-35", "", "8611567", "2005", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "34.9", "34.9", "", "", "88.6", "79.6", "", "58.1", "", "2", "", "", "102", "1", "2", "54", "6", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "98.1", "", "", "", "", "96.3"]} +{"pcdb_id": 10484, "brand_name": "Trianco", "model_name": "Eurotrader Premier 100/125", "model_qualifier": "", "winter_efficiency_pct": 87.4, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 36.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010484", "000062", "0", "2012/Mar/27 10:12", "Trianco", "Trianco", "Eurotrader Premier 100/125", "", "", "2005", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "36.6", "36.6", "", "", "87.4", "79.6", "", "58.1", "", "2", "", "", "201", "1", "1", "148", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "89.5", "93.7", "", "", "", "", "92.9"]} +{"pcdb_id": 10485, "brand_name": "Trianco", "model_name": "Eurotrader Premier 50/90", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 26.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010485", "000062", "0", "2012/Mar/27 10:12", "Trianco", "Trianco", "Eurotrader Premier 50/90", "", "", "2005", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "26.4", "26.4", "", "", "88.0", "80.2", "", "58.6", "", "2", "", "", "201", "1", "1", "148", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.0", "95.1", "", "", "", "", "94.1"]} +{"pcdb_id": 10486, "brand_name": "Trianco", "model_name": "Eurostar Premier External 50/90", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 26.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010486", "000062", "0", "2012/Mar/27 10:12", "Trianco", "Trianco", "Eurostar Premier External 50/90", "", "", "2005", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "26.4", "26.4", "", "", "88.0", "80.2", "", "58.6", "", "2", "", "", "201", "1", "1", "148", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.0", "95.1", "", "", "", "", "94.1"]} +{"pcdb_id": 10487, "brand_name": "Trianco", "model_name": "Eurostar Premier External 100/125", "model_qualifier": "", "winter_efficiency_pct": 87.4, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 36.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010487", "000062", "0", "2012/Mar/27 10:12", "Trianco", "Trianco", "Eurostar Premier External 100/125", "", "", "2005", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "36.6", "36.6", "", "", "87.4", "79.6", "", "58.1", "", "2", "", "", "201", "1", "1", "148", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "89.5", "93.7", "", "", "", "", "92.9"]} +{"pcdb_id": 10488, "brand_name": "Trianco", "model_name": "Eurostar Premier Kitchen 100/125", "model_qualifier": "", "winter_efficiency_pct": 87.4, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 36.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010488", "000062", "0", "2012/Mar/27 10:12", "Trianco", "Trianco", "Eurostar Premier Kitchen 100/125", "", "", "2005", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "36.6", "36.6", "", "", "87.4", "79.6", "", "58.1", "", "2", "", "", "201", "1", "1", "148", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "89.5", "93.7", "", "", "", "", "92.9"]} +{"pcdb_id": 10489, "brand_name": "Trianco", "model_name": "Contractor 50/70 WM", "model_qualifier": "", "winter_efficiency_pct": 85.6, "summer_efficiency_pct": 73.9, "comparative_hot_water_efficiency_pct": 54.0, "output_kw_max": 17.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010489", "000062", "0", "2012/Mar/27 10:12", "Trianco", "Trianco", "Contractor 50/70 WM", "", "", "2005", "current", "4", "2", "1", "1", "0", "", "", "1", "2", "2", "17.6", "17.6", "", "", "85.6", "73.9", "", "54.0", "", "2", "", "", "201", "1", "1", "70", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.4", "85.9", "", "", "", "", "85.8"]} +{"pcdb_id": 10490, "brand_name": "ACV", "model_name": "Prestige 24 Excellence P", "model_qualifier": "", "winter_efficiency_pct": 89.6, "summer_efficiency_pct": 82.3, "comparative_hot_water_efficiency_pct": 40.9, "output_kw_max": 23.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010490", "000243", "0", "2024/Jan/31 10:17", "ACV International", "ACV", "Prestige 24 Excellence P", "", "03617501", "2003", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "23.4", "23.4", "", "", "89.6", "82.3", "", "40.9", "", "2", "1", "", "106", "1", "2", "300", "", "2", "1", "0", "70", "0", "15", "2", "80", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.2", "100.4", "", "", "", "", "98.4"]} +{"pcdb_id": 10491, "brand_name": "ACV", "model_name": "Prestige 24 Solo P", "model_qualifier": "", "winter_efficiency_pct": 89.6, "summer_efficiency_pct": 80.6, "comparative_hot_water_efficiency_pct": 58.9, "output_kw_max": 23.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010491", "000243", "0", "2012/Mar/27 10:12", "ACV International", "ACV", "Prestige 24 Solo P", "", "03605501", "2003", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "23.4", "23.4", "", "", "89.6", "80.6", "", "58.9", "", "2", "1", "", "102", "1", "2", "200", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.2", "100.4", "", "", "", "", "98.4"]} +{"pcdb_id": 10492, "brand_name": "ACV", "model_name": "Prestige 32 Excellence P", "model_qualifier": "", "winter_efficiency_pct": 89.6, "summer_efficiency_pct": 82.3, "comparative_hot_water_efficiency_pct": 40.9, "output_kw_max": 29.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010492", "000243", "0", "2024/Jan/31 10:17", "ACV International", "ACV", "Prestige 32 Excellence P", "", "03617601", "2003", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "29.6", "29.6", "", "", "89.6", "82.3", "", "40.9", "", "2", "1", "", "106", "1", "2", "300", "", "2", "1", "0", "70", "0", "15", "2", "80", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.2", "100.4", "", "", "", "", "98.4"]} +{"pcdb_id": 10493, "brand_name": "ACV", "model_name": "Prestige 32 Solo P", "model_qualifier": "", "winter_efficiency_pct": 89.6, "summer_efficiency_pct": 80.6, "comparative_hot_water_efficiency_pct": 58.9, "output_kw_max": 29.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010493", "000243", "0", "2012/Mar/27 10:12", "ACV International", "ACV", "Prestige 32 Solo P", "", "03605601", "2003", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "29.6", "29.6", "", "", "89.6", "80.6", "", "58.9", "", "2", "1", "", "102", "1", "2", "200", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.2", "100.4", "", "", "", "", "98.4"]} +{"pcdb_id": 10494, "brand_name": "ACV", "model_name": "Prestige 50 Solo P", "model_qualifier": "", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 48.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010494", "000243", "0", "2012/Mar/27 10:12", "ACV International", "ACV", "Prestige 50 Solo P", "", "03610501", "2005", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "48.4", "48.4", "", "", "89.2", "80.2", "", "58.6", "", "2", "1", "", "102", "1", "2", "200", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.2", "99.3", "", "", "", "", "97.6"]} +{"pcdb_id": 10495, "brand_name": "ACV", "model_name": "Prestige 75 Solo P", "model_qualifier": "", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 69.9, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010495", "000243", "0", "2012/Mar/27 10:12", "ACV International", "ACV", "Prestige 75 Solo P", "", "03605601", "2005", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "69.9", "69.9", "", "", "89.2", "80.2", "", "58.6", "", "2", "1", "", "102", "1", "2", "200", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.2", "99.3", "", "", "", "", "97.6"]} +{"pcdb_id": 10496, "brand_name": "ACV", "model_name": "HeatMaster 35TC P", "model_qualifier": "", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 82.4, "comparative_hot_water_efficiency_pct": 39.8, "output_kw_max": 29.9, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 1, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010496", "000243", "0", "2024/Jan/31 10:17", "ACV International", "ACV", "HeatMaster 35TC P", "", "03620001", "2005", "current", "2", "1", "1", "2", "0", "", "", "2", "2", "2", "29.9", "29.9", "", "", "89.4", "82.4", "", "39.8", "", "2", "1", "", "106", "1", "2", "300", "", "1", "2", "0", "189", "0", "50", "2", "80", "97", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.2", "99.9", "", "", "", "", "98.1"]} +{"pcdb_id": 10498, "brand_name": "Worcester", "model_name": "Greenstar Danesmoor", "model_qualifier": "18/25-OOO-GB", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 25.0, "final_year_of_manufacture": 2013, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010498", "000035", "0", "2020/Sep/08 09:26", "Worcester Bosch Group", "Worcester", "Greenstar Danesmoor", "18/25-OOO-GB", "", "2005", "2013", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "18", "25", "", "", "88.0", "80.2", "", "58.6", "", "2", "", "", "201", "1", "1", "155", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.0", "94.7", "", "", "", "", "94.0"]} +{"pcdb_id": 10499, "brand_name": "Worcester", "model_name": "Greenstar Heatslave", "model_qualifier": "18/25-OSO-GB", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 81.9, "comparative_hot_water_efficiency_pct": 41.6, "output_kw_max": 25.0, "final_year_of_manufacture": 2013, "subsidiary_type": 0, "store_type": 1, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010499", "000035", "0", "2024/Jan/31 10:17", "Worcester Bosch Group", "Worcester", "Greenstar Heatslave", "18/25-OSO-GB", "", "2005", "2013", "4", "1", "1", "2", "0", "", "", "2", "3", "2", "18", "25", "", "", "88.0", "81.9", "", "41.6", "", "2", "", "", "203", "1", "1", "240", "0", "1", "1", "0", "69", "0", "25", "3", "82", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.0", "94.7", "", "", "", "", "94.0"]} +{"pcdb_id": 10500, "brand_name": "Worcester", "model_name": "Greenstar Utility", "model_qualifier": "18/25-OOO-GB", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 25.0, "final_year_of_manufacture": 2013, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010500", "000035", "0", "2020/Sep/08 09:26", "Worcester Bosch Group", "Worcester", "Greenstar Utility", "18/25-OOO-GB", "", "2005", "2013", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "18", "25", "", "", "88.0", "80.2", "", "58.6", "", "2", "", "", "201", "1", "1", "155", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.0", "94.7", "", "", "", "", "94.0"]} +{"pcdb_id": 10501, "brand_name": "Alpha", "model_name": "HE CB33", "model_qualifier": "", "winter_efficiency_pct": 85.3, "summer_efficiency_pct": 76.7, "comparative_hot_water_efficiency_pct": 53.9, "output_kw_max": 32.0, "final_year_of_manufacture": 2008, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010501", "000001", "0", "2011/Sep/06 13:13", "Alpha Therm", "Alpha", "HE CB33", "", "", "2005", "2008", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "32", "32", "", "", "85.3", "76.7", "", "53.9", "", "2", "", "", "104", "1", "2", "170", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.5", "90.1", "", "", "", "", "89.6"]} +{"pcdb_id": 10502, "brand_name": "Alpha", "model_name": "HE CB25", "model_qualifier": "", "winter_efficiency_pct": 85.3, "summer_efficiency_pct": 76.7, "comparative_hot_water_efficiency_pct": 53.9, "output_kw_max": 24.0, "final_year_of_manufacture": 2008, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010502", "000001", "0", "2011/Sep/06 13:13", "Alpha Therm", "Alpha", "HE CB25", "", "", "2005", "2008", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "85.3", "76.7", "", "53.9", "", "2", "", "", "104", "1", "2", "150", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.5", "90.1", "", "", "", "", "89.6"]} +{"pcdb_id": 10503, "brand_name": "Alpha", "model_name": "HE SY25", "model_qualifier": "", "winter_efficiency_pct": 85.3, "summer_efficiency_pct": 76.3, "comparative_hot_water_efficiency_pct": 55.7, "output_kw_max": 24.0, "final_year_of_manufacture": 2007, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010503", "000001", "0", "2012/Mar/27 10:12", "Alpha Therm", "Alpha", "HE SY25", "", "", "2005", "2007", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24", "24", "", "", "85.3", "76.3", "", "55.7", "", "2", "", "", "102", "1", "2", "150", "2", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.5", "90.1", "", "", "", "", "89.6"]} +{"pcdb_id": 10504, "brand_name": "Alpha", "model_name": "CD18R", "model_qualifier": "", "winter_efficiency_pct": 87.7, "summer_efficiency_pct": 78.7, "comparative_hot_water_efficiency_pct": 57.5, "output_kw_max": 18.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010504", "000001", "0", "2012/Mar/27 10:12", "Alpha Therm", "Alpha", "CD18R", "", "", "2005", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18", "18", "", "", "87.7", "78.7", "", "57.5", "", "2", "", "", "102", "1", "2", "55", "2", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "96.0", "", "", "", "", "94.5"]} +{"pcdb_id": 10506, "brand_name": "ICI Caldaie", "model_name": "Solar C25", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 56.2, "output_kw_max": 24.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010506", "000077", "0", "2005/Aug/31 10:32", "ICI Caldaie SPA", "ICI Caldaie", "Solar C25", "", "", "2005", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.4", "24.4", "", "", "88.5", "79.9", "", "56.2", "", "2", "", "", "104", "1", "2", "150", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "97.9", "", "", "", "", "96.1"]} +{"pcdb_id": 10507, "brand_name": "ICI Caldaie", "model_name": "Solar C31", "model_qualifier": "", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 56.0, "output_kw_max": 30.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010507", "000077", "0", "2005/Aug/31 10:32", "ICI Caldaie SPA", "ICI Caldaie", "Solar C31", "", "", "2005", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "30.2", "30.2", "", "", "88.2", "79.6", "", "56.0", "", "2", "", "", "104", "1", "2", "150", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "97.5", "", "", "", "", "95.7"]} +{"pcdb_id": 10508, "brand_name": "ICI Caldaie", "model_name": "Solar System C31", "model_qualifier": "", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 30.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010508", "000077", "0", "2022/May/10 10:35", "ICI Caldaie SPA", "ICI Caldaie", "Solar System C31", "", "", "2005", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "30.2", "30.2", "", "", "88.2", "79.2", "", "57.9", "", "2", "", "", "102", "1", "2", "150", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "97.5", "", "", "", "", "95.7"]} +{"pcdb_id": 10509, "brand_name": "ICI Caldaie", "model_name": "Solar System C25", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 24.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010509", "000077", "0", "2022/May/10 10:35", "ICI Caldaie SPA", "ICI Caldaie", "Solar System C25", "", "", "2005", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24.4", "24.4", "", "", "88.5", "79.5", "", "58.0", "", "2", "", "", "102", "1", "2", "150", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "97.9", "", "", "", "", "96.1"]} +{"pcdb_id": 10510, "brand_name": "Gledhill", "model_name": "GB30", "model_qualifier": "AGB5030", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 32.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010510", "000072", "0", "2012/Mar/27 10:12", "Gledhill Water Storage", "Gledhill", "GB30", "AGB5030", "", "2005", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "32", "32", "", "", "88.6", "79.6", "", "58.1", "", "2", "", "", "102", "1", "2", "60", "6.5", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.2", "98.1", "", "", "", "", "96.2"]} +{"pcdb_id": 10511, "brand_name": "Gledhill", "model_name": "GB25", "model_qualifier": "AGB5025", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 27.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010511", "000072", "0", "2012/Mar/27 10:12", "Gledhill Water Storage", "Gledhill", "GB25", "AGB5025", "", "2005", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "27.2", "27.2", "", "", "88.6", "79.6", "", "58.2", "", "2", "", "", "102", "1", "2", "60", "6.5", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.4", "98.2", "", "", "", "", "96.3"]} +{"pcdb_id": 10512, "brand_name": "Gledhill", "model_name": "GB20", "model_qualifier": "AGB5020", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 22.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010512", "000072", "0", "2012/Mar/27 10:12", "Gledhill Water Storage", "Gledhill", "GB20", "AGB5020", "", "2005", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "22", "22", "", "", "88.2", "79.2", "", "57.9", "", "2", "", "", "102", "1", "2", "60", "6.5", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.5", "97.2", "", "", "", "", "95.6"]} +{"pcdb_id": 10513, "brand_name": "Gledhill", "model_name": "GB15", "model_qualifier": "AGB5015", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 16.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010513", "000072", "0", "2012/Mar/27 10:12", "Gledhill Water Storage", "Gledhill", "GB15", "AGB5015", "", "2005", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "16.4", "16.4", "", "", "88.1", "79.1", "", "57.8", "", "2", "", "", "102", "1", "2", "60", "6.5", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.7", "96.9", "", "", "", "", "95.3"]} +{"pcdb_id": 10514, "brand_name": "Gledhill", "model_name": "GB10", "model_qualifier": "AGB5010", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 10.87, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010514", "000072", "0", "2012/Mar/27 10:12", "Gledhill Water Storage", "Gledhill", "GB10", "AGB5010", "", "2005", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "10.87", "10.87", "", "", "88.5", "79.5", "", "58.1", "", "2", "", "", "102", "1", "2", "60", "6.5", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "98.0", "", "", "", "", "96.1"]} +{"pcdb_id": 10515, "brand_name": "Warmflow", "model_name": "Combi", "model_qualifier": "C90HE", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 81.9, "comparative_hot_water_efficiency_pct": 41.4, "output_kw_max": 26.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 1, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010515", "000063", "0", "2024/Jan/31 10:17", "Warmflow Engineering", "Warmflow", "Combi", "C90HE", "", "2005", "current", "4", "1", "1", "2", "0", "", "", "2", "3", "2", "21", "26", "", "", "88.0", "81.9", "", "41.4", "", "2", "", "", "203", "1", "1", "250", "0", "1", "1", "0", "70", "0", "25", "6", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.8", "94.8", "", "", "", "", "94.1"]} +{"pcdb_id": 10516, "brand_name": "Warmflow", "model_name": "System", "model_qualifier": "S90HE", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 26.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010516", "000063", "0", "2012/Mar/27 10:12", "Warmflow Engineering", "Warmflow", "System", "S90HE", "", "2005", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "21", "26", "", "", "88.0", "80.2", "", "58.6", "", "2", "", "", "201", "1", "1", "160", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.8", "94.8", "", "", "", "", "94.1"]} +{"pcdb_id": 10517, "brand_name": "Warmflow", "model_name": "System", "model_qualifier": "S70HE", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 21.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010517", "000063", "0", "2012/Mar/27 10:12", "Warmflow Engineering", "Warmflow", "System", "S70HE", "", "2005", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "15", "21", "", "", "87.9", "80.1", "", "58.5", "", "2", "", "", "201", "1", "1", "160", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "89.5", "95.0", "", "", "", "", "94.0"]} +{"pcdb_id": 10518, "brand_name": "Warmflow", "model_name": "Utility", "model_qualifier": "U120HE", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 33.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010518", "000063", "0", "2013/Mar/28 08:27", "Warmflow Engineering", "Warmflow", "Utility", "U120HE", "", "2005", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "26", "33", "", "", "87.9", "80.1", "", "58.5", "", "2", "", "", "201", "1", "1", "160", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.1", "94.7", "", "", "", "", "93.9"]} +{"pcdb_id": 10519, "brand_name": "Warmflow", "model_name": "Utility", "model_qualifier": "U90HE", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 26.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010519", "000063", "0", "2013/Mar/28 08:27", "Warmflow Engineering", "Warmflow", "Utility", "U90HE", "", "2005", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "21", "26", "", "", "88.0", "80.2", "", "58.6", "", "2", "", "", "201", "1", "1", "160", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.8", "94.8", "", "", "", "", "94.1"]} +{"pcdb_id": 10520, "brand_name": "Warmflow", "model_name": "Utility", "model_qualifier": "U70HE", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 21.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010520", "000063", "0", "2013/Mar/28 08:27", "Warmflow Engineering", "Warmflow", "Utility", "U70HE", "", "2005", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "15", "21", "", "", "87.9", "80.1", "", "58.5", "", "2", "", "", "201", "1", "1", "160", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "89.5", "95.0", "", "", "", "", "94.0"]} +{"pcdb_id": 10521, "brand_name": "Saunier Duval", "model_name": "SD Thema Condens F 18 E SB", "model_qualifier": "", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 17.9, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010521", "000206", "0", "2012/Mar/27 10:12", "Vaillant Group", "Saunier Duval", "SD Thema Condens F 18 E SB", "", "", "2005", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "17.90", "17.90", "", "", "89.1", "80.1", "", "58.5", "", "2", "1", "", "102", "1", "2", "144", "8", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.0", "99.2", "", "", "", "", "97.4"]} +{"pcdb_id": 10522, "brand_name": "Saunier Duval", "model_name": "SD Thema Condens F 18 E SB", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 17.9, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010522", "000206", "0", "2012/Mar/27 10:12", "Vaillant Group", "Saunier Duval", "SD Thema Condens F 18 E SB", "", "GC 41-920-47", "2005", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "17.90", "17.90", "", "", "88.1", "79.1", "", "57.8", "", "2", "", "", "102", "1", "2", "144", "8", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "97.0", "", "", "", "", "95.3"]} +{"pcdb_id": 10523, "brand_name": "Saunier Duval", "model_name": "SD Thema Condens F 24 E", "model_qualifier": "", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 56.6, "output_kw_max": 17.9, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010523", "000206", "0", "2009/Mar/31 14:29", "Vaillant Group", "Saunier Duval", "SD Thema Condens F 24 E", "", "", "2005", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "17.90", "17.90", "", "", "89.1", "80.5", "", "56.6", "", "2", "1", "", "104", "1", "2", "142", "8", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.0", "99.2", "", "", "", "", "97.4"]} +{"pcdb_id": 10525, "brand_name": "Saunier Duval", "model_name": "SD Thema Condens F 24 E", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 55.9, "output_kw_max": 17.9, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010525", "000206", "0", "2009/Mar/31 14:33", "Vaillant Group", "Saunier Duval", "SD Thema Condens F 24 E", "", "GC 47-920-48", "2005", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "17.90", "17.90", "", "", "88.1", "79.5", "", "55.9", "", "2", "", "", "104", "1", "2", "142", "8", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "97.0", "", "", "", "", "95.3"]} +{"pcdb_id": 10526, "brand_name": "Saunier Duval", "model_name": "SD Thema Condens F 30 E", "model_qualifier": "", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 80.6, "comparative_hot_water_efficiency_pct": 56.7, "output_kw_max": 23.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010526", "000206", "0", "2009/Mar/31 14:29", "Vaillant Group", "Saunier Duval", "SD Thema Condens F 30 E", "", "", "2005", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "23.60", "23.60", "", "", "89.2", "80.6", "", "56.7", "", "2", "1", "", "104", "1", "2", "144", "8", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.2", "99.3", "", "", "", "", "97.6"]} +{"pcdb_id": 10527, "brand_name": "Saunier Duval", "model_name": "SD Thema Condens F 30 E", "model_qualifier": "", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 56.0, "output_kw_max": 23.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010527", "000206", "0", "2009/Mar/31 14:33", "Vaillant Group", "Saunier Duval", "SD Thema Condens F 30 E", "", "GC 47-920-49", "2005", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "23.60", "23.60", "", "", "88.2", "79.6", "", "56.0", "", "2", "", "", "104", "1", "2", "144", "8", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.2", "97.1", "", "", "", "", "95.4"]} +{"pcdb_id": 10528, "brand_name": "Saunier Duval", "model_name": "SD Themaplus Condens F 30 E", "model_qualifier": "", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 80.6, "comparative_hot_water_efficiency_pct": 56.7, "output_kw_max": 23.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010528", "000206", "0", "2009/Mar/31 14:29", "Vaillant Group", "Saunier Duval", "SD Themaplus Condens F 30 E", "", "", "2005", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "23.60", "23.60", "", "", "89.2", "80.6", "", "56.7", "", "2", "1", "", "104", "1", "2", "174", "8", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.2", "99.3", "", "", "", "", "97.6"]} +{"pcdb_id": 10529, "brand_name": "Saunier Duval", "model_name": "SD Themaplus Condens F 30 E", "model_qualifier": "", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 56.0, "output_kw_max": 23.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010529", "000206", "0", "2009/Mar/31 14:34", "Vaillant Group", "Saunier Duval", "SD Themaplus Condens F 30 E", "", "GC 47-920-50", "2005", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "23.60", "23.60", "", "", "88.2", "79.6", "", "56.0", "", "2", "", "", "104", "1", "2", "174", "8", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.2", "97.1", "", "", "", "", "95.4"]} +{"pcdb_id": 10531, "brand_name": "Alpha", "model_name": "CD18R", "model_qualifier": "", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 18.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010531", "000001", "0", "2012/Mar/27 10:12", "Alpha Therm", "Alpha", "CD18R", "", "", "2005", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "18.0", "18.0", "", "", "88.7", "79.7", "", "58.2", "", "2", "1", "", "102", "1", "2", "55", "2", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.3", "98.1", "", "", "", "", "96.6"]} +{"pcdb_id": 10532, "brand_name": "Sime", "model_name": "Dewy 30/80 HE FS", "model_qualifier": "", "winter_efficiency_pct": 90.3, "summer_efficiency_pct": 83.0, "comparative_hot_water_efficiency_pct": 47.1, "output_kw_max": 29.3, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010532", "000213", "0", "2024/Jan/31 10:17", "Fonderie Sime S.p.A.", "Sime", "Dewy 30/80 HE FS", "", "", "2005", "2018", "2", "1", "1", "2", "0", "", "", "2", "3", "2", "29.3", "29.3", "", "", "90.3", "83.0", "", "47.1", "", "2", "1", "", "106", "1", "2", "175", "10", "2", "", "0", "80", "0", "25", "2", "60", "578", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.3", "102.2", "", "", "", "", "100.0"]} +{"pcdb_id": 10533, "brand_name": "Sime", "model_name": "Dewy 30/80 HE FS", "model_qualifier": "", "winter_efficiency_pct": 89.3, "summer_efficiency_pct": 82.0, "comparative_hot_water_efficiency_pct": 46.5, "output_kw_max": 29.3, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010533", "000213", "0", "2024/Jan/31 10:17", "Fonderie Sime S.p.A.", "Sime", "Dewy 30/80 HE FS", "", "", "2005", "2018", "1", "1", "1", "2", "0", "", "", "2", "3", "2", "29.3", "29.3", "", "", "89.3", "82.0", "", "46.5", "", "2", "", "", "106", "1", "2", "175", "10", "2", "1", "0", "80", "0", "25", "", "60", "578", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "100.0", "", "", "", "", "97.8"]} +{"pcdb_id": 10534, "brand_name": "Sime", "model_name": "Dewy 30/130 HE FS", "model_qualifier": "", "winter_efficiency_pct": 90.3, "summer_efficiency_pct": 83.0, "comparative_hot_water_efficiency_pct": 44.8, "output_kw_max": 29.3, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010534", "000213", "0", "2024/Jan/31 10:17", "Fonderie Sime S.p.A.", "Sime", "Dewy 30/130 HE FS", "", "", "2005", "2018", "2", "1", "1", "2", "0", "", "", "2", "3", "2", "29.3", "29.3", "", "", "90.3", "83.0", "", "44.8", "", "2", "1", "", "106", "1", "2", "175", "10", "2", "", "0", "130", "0", "30", "2", "60", "291", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.3", "102.2", "", "", "", "", "100.0"]} +{"pcdb_id": 10535, "brand_name": "Sime", "model_name": "Dewy 30/130 HE FS", "model_qualifier": "", "winter_efficiency_pct": 89.3, "summer_efficiency_pct": 82.0, "comparative_hot_water_efficiency_pct": 44.3, "output_kw_max": 29.3, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010535", "000213", "0", "2024/Jan/31 10:17", "Fonderie Sime S.p.A.", "Sime", "Dewy 30/130 HE FS", "", "", "2005", "2018", "1", "1", "1", "2", "0", "", "", "2", "3", "2", "29.3", "29.3", "", "", "89.3", "82.0", "", "44.3", "", "2", "", "", "106", "1", "2", "175", "10", "2", "1", "0", "130", "0", "30", "2", "60", "291", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "100.0", "", "", "", "", "97.8"]} +{"pcdb_id": 10536, "brand_name": "Sime", "model_name": "Dewy HE 30/50 WM LPG", "model_qualifier": "", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 81.4, "comparative_hot_water_efficiency_pct": 52.0, "output_kw_max": 29.2, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010536", "000213", "0", "2024/Jan/31 10:17", "Fonderie Sime S.p.A.", "Sime", "Dewy HE 30/50 WM LPG", "", "", "2005", "2018", "2", "2", "1", "2", "0", "", "", "2", "3", "2", "29.2", "29.2", "", "", "88.7", "81.4", "", "52.0", "", "2", "1", "", "106", "1", "2", "175", "10", "2", "", "0", "50", "0", "30", "2", "60", "246", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.5", "98.3", "", "", "", "", "96.6"]} +{"pcdb_id": 10537, "brand_name": "Sime", "model_name": "Dewy HE 30/50 WM", "model_qualifier": "", "winter_efficiency_pct": 87.7, "summer_efficiency_pct": 80.4, "comparative_hot_water_efficiency_pct": 51.4, "output_kw_max": 29.2, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010537", "000213", "0", "2024/Jan/31 10:17", "Fonderie Sime S.p.A.", "Sime", "Dewy HE 30/50 WM", "", "", "2005", "2018", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "29.2", "29.2", "", "", "87.7", "80.4", "", "51.4", "", "2", "", "", "106", "1", "2", "175", "10", "2", "1", "0", "50", "0", "30", "2", "60", "246", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.6", "96.1", "", "", "", "", "94.5"]} +{"pcdb_id": 10538, "brand_name": "Sime", "model_name": "Ecomfort 30 HE LPG", "model_qualifier": "", "winter_efficiency_pct": 87.2, "summer_efficiency_pct": 78.6, "comparative_hot_water_efficiency_pct": 55.3, "output_kw_max": 29.1, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010538", "000213", "0", "2018/Feb/26 16:49", "Fonderie Sime S.p.A.", "Sime", "Ecomfort 30 HE LPG", "", "", "2005", "2018", "2", "2", "1", "2", "0", "", "", "2", "3", "2", "29.1", "29.1", "", "", "87.2", "78.6", "", "55.3", "", "2", "1", "", "104", "1", "2", "180", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.2", "94.7", "", "", "", "", "93.6"]} +{"pcdb_id": 10539, "brand_name": "Sime", "model_name": "Ecomfort 30 HE", "model_qualifier": "", "winter_efficiency_pct": 86.2, "summer_efficiency_pct": 77.6, "comparative_hot_water_efficiency_pct": 54.6, "output_kw_max": 29.1, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010539", "000213", "0", "2018/Feb/26 16:48", "Fonderie Sime S.p.A.", "Sime", "Ecomfort 30 HE", "", "", "2005", "2018", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "29.1", "29.1", "", "", "86.2", "77.6", "", "54.6", "", "2", "", "", "104", "1", "2", "180", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.3", "92.6", "", "", "", "", "91.6"]} +{"pcdb_id": 10540, "brand_name": "Ariston", "model_name": "Combi A 30 MFFI", "model_qualifier": "Combi A", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 56.6, "output_kw_max": 30.0, "final_year_of_manufacture": 2007, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010540", "000080", "0", "2008/Jun/26 09:06", "Merloni TermoSanitari SpA", "Ariston", "Combi A 30 MFFI", "Combi A", "GC No. 47-116-45", "2005", "2007", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "30", "30", "", "", "89.1", "80.5", "", "56.6", "", "2", "", "", "104", "1", "2", "148", "7", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "99.4", "", "", "", "", "97.3"]} +{"pcdb_id": 10541, "brand_name": "Ariston", "model_name": "Combi A 24 MFFI", "model_qualifier": "Combi A", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 56.1, "output_kw_max": 25.0, "final_year_of_manufacture": 2007, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010541", "000080", "0", "2008/Jun/26 09:06", "Merloni TermoSanitari SpA", "Ariston", "Combi A 24 MFFI", "Combi A", "GC No. 47-116-44", "2005", "2007", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "25", "25", "", "", "88.4", "79.8", "", "56.1", "", "2", "", "", "104", "1", "2", "148", "7", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "97.6", "", "", "", "", "95.8"]} +{"pcdb_id": 10542, "brand_name": "Ideal", "model_name": "Classic", "model_qualifier": "HE 15 P", "winter_efficiency_pct": 86.6, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 14.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010542", "000008", "0", "2012/Mar/27 10:12", "Ideal Boilers", "Ideal", "Classic", "HE 15 P", "41-421-97", "2005", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "14.4", "14.4", "", "", "86.6", "79.0", "", "57.7", "", "2", "0", "", "101", "1", "1", "100", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "88.4", "94.6", "", "", "", "", "93.4"]} +{"pcdb_id": 10543, "brand_name": "Ideal", "model_name": "Classic", "model_qualifier": "HE 18 P", "winter_efficiency_pct": 85.7, "summer_efficiency_pct": 78.1, "comparative_hot_water_efficiency_pct": 57.1, "output_kw_max": 18.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010543", "000008", "0", "2012/Mar/27 10:12", "Ideal Boilers", "Ideal", "Classic", "HE 18 P", "41-421-98", "2005", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "18.3", "18.3", "", "", "85.7", "78.1", "", "57.1", "", "2", "0", "", "101", "1", "1", "100", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "87.9", "92.6", "", "", "", "", "91.7"]} +{"pcdb_id": 10546, "brand_name": "Broag Remeha", "model_name": "Avanta Plus", "model_qualifier": "24s", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 22.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010546", "000005", "0", "2012/Apr/11 14:49", "Remeha", "Broag Remeha", "Avanta Plus", "24s", "4128805", "2005", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "22", "22", "", "", "88.5", "79.5", "", "58.1", "", "2", "", "", "102", "1", "2", "115", "3", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.6", "97.9", "", "", "", "", "96.2"]} +{"pcdb_id": 10547, "brand_name": "Broag Remeha", "model_name": "Avanta Plus", "model_qualifier": "28c", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 56.2, "output_kw_max": 22.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010547", "000005", "0", "2012/Apr/11 14:49", "Remeha", "Broag Remeha", "Avanta Plus", "28c", "4767302", "2005", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "22", "22", "", "", "88.5", "79.9", "", "56.2", "", "2", "", "", "104", "1", "2", "115", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.6", "97.9", "", "", "", "", "96.2"]} +{"pcdb_id": 10548, "brand_name": "Broag Remeha", "model_name": "Avanta Plus", "model_qualifier": "39c", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 56.6, "output_kw_max": 34.8, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010548", "000005", "0", "2012/Apr/11 14:49", "Remeha", "Broag Remeha", "Avanta Plus", "39c", "4767304", "2005", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "34.8", "34.8", "", "", "89.1", "80.5", "", "56.6", "", "2", "", "", "104", "1", "2", "180", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "99.6", "", "", "", "", "97.4"]} +{"pcdb_id": 10549, "brand_name": "Sabre", "model_name": "25HE", "model_qualifier": "", "winter_efficiency_pct": 85.4, "summer_efficiency_pct": 76.8, "comparative_hot_water_efficiency_pct": 54.0, "output_kw_max": 24.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010549", "000011", "0", "2006/Jan/17 12:31", "Vokera", "Sabre", "25HE", "", "4709470", "2005", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.3", "24.3", "", "", "85.4", "76.8", "", "54.0", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.4", "90.6", "", "", "", "", "90.0"]} +{"pcdb_id": 10550, "brand_name": "Sabre", "model_name": "29HE", "model_qualifier": "", "winter_efficiency_pct": 85.6, "summer_efficiency_pct": 77.0, "comparative_hot_water_efficiency_pct": 54.1, "output_kw_max": 28.1, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010550", "000011", "0", "2006/Jan/17 12:31", "Vokera", "Sabre", "29HE", "", "4709471", "2005", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28.1", "28.1", "", "", "85.6", "77.0", "", "54.1", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.4", "90.9", "", "", "", "", "90.2"]} +{"pcdb_id": 10551, "brand_name": "Sabre", "model_name": "29HE", "model_qualifier": "System", "winter_efficiency_pct": 85.6, "summer_efficiency_pct": 76.6, "comparative_hot_water_efficiency_pct": 55.9, "output_kw_max": 28.1, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010551", "000011", "0", "2012/Mar/27 10:12", "Vokera", "Sabre", "29HE", "System", "4709443", "2005", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "28.1", "28.1", "", "", "85.6", "76.6", "", "55.9", "", "2", "", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.4", "90.9", "", "", "", "", "90.2"]} +{"pcdb_id": 10552, "brand_name": "Vokera", "model_name": "Compact", "model_qualifier": "25HE", "winter_efficiency_pct": 85.4, "summer_efficiency_pct": 76.8, "comparative_hot_water_efficiency_pct": 54.0, "output_kw_max": 24.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010552", "000011", "0", "2006/Jan/17 12:31", "Vokera", "Vokera", "Compact", "25HE", "4709474", "2005", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.3", "24.3", "", "", "85.4", "76.8", "", "54.0", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.4", "90.6", "", "", "", "", "90.0"]} +{"pcdb_id": 10554, "brand_name": "Vokera", "model_name": "Compact", "model_qualifier": "29HE", "winter_efficiency_pct": 85.6, "summer_efficiency_pct": 77.0, "comparative_hot_water_efficiency_pct": 54.1, "output_kw_max": 28.1, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010554", "000011", "0", "2006/Jan/17 12:31", "Vokera", "Vokera", "Compact", "29HE", "4709476", "2005", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28.1", "28.1", "", "", "85.6", "77.0", "", "54.1", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.4", "90.9", "", "", "", "", "90.2"]} +{"pcdb_id": 10556, "brand_name": "Potterton", "model_name": "Gold", "model_qualifier": "33 HE", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 55.8, "output_kw_max": 28.0, "final_year_of_manufacture": 2008, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010556", "000005", "0", "2010/Nov/19 09:18", "Baxi Potterton", "Potterton", "Gold", "33 HE", "GC No. 47-590-19", "2005", "2008", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28", "28", "", "", "87.9", "79.3", "", "55.8", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "96.7", "", "", "", "", "95.0"]} +{"pcdb_id": 10557, "brand_name": "Potterton", "model_name": "Gold", "model_qualifier": "28 HE", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 55.8, "output_kw_max": 24.0, "final_year_of_manufacture": 2008, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010557", "000005", "0", "2010/Nov/19 09:18", "Baxi Potterton", "Potterton", "Gold", "28 HE", "GC No. 47-590-06", "2005", "2008", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "88.0", "79.4", "", "55.8", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "96.9", "", "", "", "", "95.2"]} +{"pcdb_id": 10558, "brand_name": "Baxi", "model_name": "Platinum", "model_qualifier": "33 HE", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 55.8, "output_kw_max": 28.0, "final_year_of_manufacture": 2007, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010558", "000005", "0", "2010/Nov/19 09:04", "Baxi Potterton", "Baxi", "Platinum", "33 HE", "GC No. 47-075-22", "2005", "2007", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28", "28", "", "", "87.9", "79.3", "", "55.8", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "96.7", "", "", "", "", "95.0"]} +{"pcdb_id": 10559, "brand_name": "Baxi", "model_name": "Platinum", "model_qualifier": "28 HE", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 55.8, "output_kw_max": 24.0, "final_year_of_manufacture": 2007, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010559", "000005", "0", "2010/Nov/19 09:03", "Baxi Potterton", "Baxi", "Platinum", "28 HE", "GC No. 47-075-21", "2005", "2007", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "88.0", "79.4", "", "55.8", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "96.9", "", "", "", "", "95.2"]} +{"pcdb_id": 10560, "brand_name": "SARIgas", "model_name": "Zoom", "model_qualifier": "ZF 420A", "winter_efficiency_pct": 79.2, "summer_efficiency_pct": 69.1, "comparative_hot_water_efficiency_pct": 48.6, "output_kw_max": 23.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010560", "000244", "0", "2005/Sep/30 13:47", "SARIgas", "SARIgas", "Zoom", "ZF 420A", "", "2000", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "23.5", "23.5", "", "", "79.2", "69.1", "", "48.6", "", "2", "", "", "104", "1", "2", "140", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "81.5", "79.3", "", "", "", "", "79.7"]} +{"pcdb_id": 10561, "brand_name": "SARIgas", "model_name": "Max", "model_qualifier": "MF 25 A", "winter_efficiency_pct": 80.7, "summer_efficiency_pct": 71.6, "comparative_hot_water_efficiency_pct": 35.0, "output_kw_max": 29.1, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 1, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010561", "000244", "0", "2024/Jan/31 10:17", "SARIgas", "SARIgas", "Max", "MF 25 A", "", "1998", "current", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "29.1", "29.1", "", "", "80.7", "71.6", "", "35.0", "", "2", "", "", "106", "1", "2", "160", "10", "1", "1", "0", "59", "0", "20", "5", "60", "2", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.4", "80.8", "", "", "", "", "81.1"]} +{"pcdb_id": 10562, "brand_name": "Saunier Duval", "model_name": "Xeon Condens 30", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 28.17, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010562", "000206", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Saunier Duval", "Xeon Condens 30", "", "GC 41-920-46", "2005", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "28.17", "28.17", "", "", "88.1", "79.1", "", "57.8", "", "2", "", "", "102", "1", "2", "60", "15", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.7", "96.9", "", "", "", "", "95.3"]} +{"pcdb_id": 10563, "brand_name": "Saunier Duval", "model_name": "Xeon Condens 30 LPG", "model_qualifier": "", "winter_efficiency_pct": 90.0, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 59.2, "output_kw_max": 28.17, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010563", "000206", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Saunier Duval", "Xeon Condens 30 LPG", "", "", "2005", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "28.17", "28.17", "", "", "90.0", "81.0", "", "59.2", "", "2", "0", "", "102", "1", "2", "60", "15", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.8", "99.0", "", "", "", "", "97.3"]} +{"pcdb_id": 10564, "brand_name": "Saunier Duval", "model_name": "Xeon Condens 18", "model_qualifier": "", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 78.9, "comparative_hot_water_efficiency_pct": 57.6, "output_kw_max": 18.57, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010564", "000206", "0", "2012/Mar/27 10:12", "Hepworth Heating", "Saunier Duval", "Xeon Condens 18", "", "GC 41-920-38", "2005", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18.57", "18.57", "", "", "87.9", "78.9", "", "57.6", "", "2", "", "", "102", "1", "2", "60", "15", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.6", "96.3", "", "", "", "", "94.8"]} +{"pcdb_id": 10565, "brand_name": "Main", "model_name": "Combi", "model_qualifier": "30 HE", "winter_efficiency_pct": 85.8, "summer_efficiency_pct": 77.2, "comparative_hot_water_efficiency_pct": 54.3, "output_kw_max": 29.6, "final_year_of_manufacture": 2012, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010565", "000005", "0", "2013/May/07 10:29", "Baxi Potterton", "Main", "Combi", "30 HE", "GC No. 47-474-03", "2005", "2012", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "29.6", "29.6", "", "", "85.8", "77.2", "", "54.3", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.6", "91.3", "", "", "", "", "90.6"]} +{"pcdb_id": 10566, "brand_name": "Johnson & Starley", "model_name": "Reno", "model_qualifier": "HE16H", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 16.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010566", "000239", "0", "2012/Mar/27 10:12", "Johnson & Starley", "Johnson & Starley", "Reno", "HE16H", "4141607", "2005", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "16.0", "16.0", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "9.5", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.0", "97.3", "", "", "", "", "95.7"]} +{"pcdb_id": 10567, "brand_name": "Johnson & Starley", "model_name": "Reno", "model_qualifier": "HE16S", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 16.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010567", "000239", "0", "2012/Mar/27 10:12", "Johnson & Starley", "Johnson & Starley", "Reno", "HE16S", "4141605", "2005", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "16.0", "16.0", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "145", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.0", "97.3", "", "", "", "", "95.7"]} +{"pcdb_id": 10568, "brand_name": "Johnson & Starley", "model_name": "Reno", "model_qualifier": "HE31H", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 30.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010568", "000239", "0", "2012/Mar/27 10:12", "Johnson & Starley", "Johnson & Starley", "Reno", "HE31H", "4141606", "2005", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "30.0", "30.0", "", "", "88.1", "79.1", "", "57.8", "", "2", "", "", "102", "1", "2", "95", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "97.0", "", "", "", "", "95.3"]} +{"pcdb_id": 10569, "brand_name": "Johnson & Starley", "model_name": "Reno", "model_qualifier": "HE31S", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 30.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010569", "000239", "0", "2012/Mar/27 10:12", "Johnson & Starley", "Johnson & Starley", "Reno", "HE31S", "4141604", "2005", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "30.0", "30.0", "", "", "88.1", "79.1", "", "57.8", "", "2", "", "", "102", "1", "2", "145", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "97.0", "", "", "", "", "95.3"]} +{"pcdb_id": 10570, "brand_name": "Johnson & Starley", "model_name": "Reno", "model_qualifier": "HE37C", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 55.9, "output_kw_max": 30.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010570", "000239", "0", "2009/Oct/28 09:39", "Johnson & Starley", "Johnson & Starley", "Reno", "HE37C", "4141602", "2005", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "30.0", "30.0", "", "", "88.1", "79.5", "", "55.9", "", "2", "", "", "104", "1", "2", "145", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "97.0", "", "", "", "", "95.3"]} +{"pcdb_id": 10571, "brand_name": "Johnson & Starley", "model_name": "Reno", "model_qualifier": "HE16SP", "winter_efficiency_pct": 90.4, "summer_efficiency_pct": 81.4, "comparative_hot_water_efficiency_pct": 59.5, "output_kw_max": 16.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010571", "000239", "0", "2012/Mar/27 10:12", "Johnson & Starley", "Johnson & Starley", "Reno", "HE16SP", "", "2005", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "16.0", "16.0", "", "", "90.4", "81.4", "", "59.5", "", "2", "0", "", "102", "1", "2", "145", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "91.0", "99.5", "", "", "", "", "97.9"]} +{"pcdb_id": 10572, "brand_name": "Johnson & Starley", "model_name": "Reno", "model_qualifier": "HE16HP", "winter_efficiency_pct": 90.4, "summer_efficiency_pct": 81.4, "comparative_hot_water_efficiency_pct": 59.5, "output_kw_max": 16.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010572", "000239", "0", "2012/Mar/27 10:12", "Johnson & Starley", "Johnson & Starley", "Reno", "HE16HP", "", "2005", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "16.0", "16.0", "", "", "90.4", "81.4", "", "59.5", "", "2", "0", "", "102", "1", "2", "95", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "91.0", "99.5", "", "", "", "", "97.9"]} +{"pcdb_id": 10573, "brand_name": "Johnson & Starley", "model_name": "Reno", "model_qualifier": "HE31SP", "winter_efficiency_pct": 90.3, "summer_efficiency_pct": 81.3, "comparative_hot_water_efficiency_pct": 59.4, "output_kw_max": 30.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010573", "000239", "0", "2012/Mar/27 10:12", "Johnson & Starley", "Johnson & Starley", "Reno", "HE31SP", "", "2005", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "30.0", "30.0", "", "", "90.3", "81.3", "", "59.4", "", "2", "0", "", "102", "1", "2", "145", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.5", "99.9", "", "", "", "", "98.0"]} +{"pcdb_id": 10574, "brand_name": "Johnson & Starley", "model_name": "Reno", "model_qualifier": "HE31HP", "winter_efficiency_pct": 90.3, "summer_efficiency_pct": 81.3, "comparative_hot_water_efficiency_pct": 59.4, "output_kw_max": 30.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010574", "000239", "0", "2012/Mar/27 10:12", "Johnson & Starley", "Johnson & Starley", "Reno", "HE31HP", "", "2005", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "30.0", "30.0", "", "", "90.3", "81.3", "", "59.4", "", "2", "0", "", "102", "1", "2", "95", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.5", "99.9", "", "", "", "", "98.0"]} +{"pcdb_id": 10575, "brand_name": "Johnson & Starley", "model_name": "Reno", "model_qualifier": "HE37CP", "winter_efficiency_pct": 90.3, "summer_efficiency_pct": 81.7, "comparative_hot_water_efficiency_pct": 57.5, "output_kw_max": 30.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010575", "000239", "0", "2006/Jan/17 12:31", "Johnson & Starley", "Johnson & Starley", "Reno", "HE37CP", "", "2005", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "30.0", "30.0", "", "", "90.3", "81.7", "", "57.5", "", "2", "0", "", "104", "1", "2", "145", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.5", "99.9", "", "", "", "", "98.0"]} +{"pcdb_id": 10577, "brand_name": "Biasi", "model_name": "Riva Advance HE", "model_qualifier": "M110.24SM/C", "winter_efficiency_pct": 87.8, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 55.7, "output_kw_max": 25.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010577", "000208", "0", "2006/Jan/17 12:31", "Biasi", "Biasi", "Riva Advance HE", "M110.24SM/C", "47-970-29", "2004", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "25", "25", "", "", "87.8", "79.2", "", "55.7", "", "2", "", "", "104", "1", "2", "108", "6", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "96.4", "", "", "", "", "94.8"]} +{"pcdb_id": 10578, "brand_name": "Biasi", "model_name": "Garda Plus HE Silver", "model_qualifier": "M110.24SM/D", "winter_efficiency_pct": 87.8, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 55.7, "output_kw_max": 25.0, "final_year_of_manufacture": 2008, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010578", "000208", "0", "2008/May/22 11:20", "Biasi", "Biasi", "Garda Plus HE Silver", "M110.24SM/D", "47-970-33", "2004", "2008", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "25", "25", "", "", "87.8", "79.2", "", "55.7", "", "2", "", "", "104", "1", "2", "108", "6", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "96.4", "", "", "", "", "94.8"]} +{"pcdb_id": 10579, "brand_name": "Biasi", "model_name": "Garda Plus HE", "model_qualifier": "M110.24SM/E", "winter_efficiency_pct": 87.8, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 55.7, "output_kw_max": 25.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010579", "000208", "0", "2006/Jan/17 12:31", "Biasi", "Biasi", "Garda Plus HE", "M110.24SM/E", "47-970-31", "2004", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "25", "25", "", "", "87.8", "79.2", "", "55.7", "", "2", "", "", "104", "1", "2", "108", "6", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "96.4", "", "", "", "", "94.8"]} +{"pcdb_id": 10580, "brand_name": "Biasi", "model_name": "Riva Advance HE", "model_qualifier": "M110.32SM/C", "winter_efficiency_pct": 87.8, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 55.7, "output_kw_max": 33.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010580", "000208", "0", "2006/Jan/17 12:31", "Biasi", "Biasi", "Riva Advance HE", "M110.32SM/C", "47-970-30", "2004", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "33.5", "33.5", "", "", "87.8", "79.2", "", "55.7", "", "2", "", "", "104", "1", "2", "125", "6", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "96.2", "", "", "", "", "94.7"]} +{"pcdb_id": 10581, "brand_name": "Biasi", "model_name": "Garda Plus HE Silver", "model_qualifier": "M110.32SM/D", "winter_efficiency_pct": 87.8, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 55.7, "output_kw_max": 33.5, "final_year_of_manufacture": 2008, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010581", "000208", "0", "2008/May/22 11:20", "Biasi", "Biasi", "Garda Plus HE Silver", "M110.32SM/D", "47-970-34", "2004", "2008", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "33.5", "33.5", "", "", "87.8", "79.2", "", "55.7", "", "2", "", "", "104", "1", "2", "125", "6", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "96.2", "", "", "", "", "94.7"]} +{"pcdb_id": 10582, "brand_name": "Biasi", "model_name": "Garda Plus HE", "model_qualifier": "M110.32SM/E", "winter_efficiency_pct": 87.8, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 55.7, "output_kw_max": 33.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010582", "000208", "0", "2006/Jan/17 12:31", "Biasi", "Biasi", "Garda Plus HE", "M110.32SM/E", "47-970-32", "2004", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "33.5", "33.5", "", "", "87.8", "79.2", "", "55.7", "", "2", "", "", "104", "1", "2", "125", "6", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "96.2", "", "", "", "", "94.7"]} +{"pcdb_id": 10583, "brand_name": "Baxi", "model_name": "Platinum System", "model_qualifier": "24 HE", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 24.0, "final_year_of_manufacture": 2007, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010583", "000005", "0", "2012/Mar/27 10:12", "Baxi Potterton", "Baxi", "Platinum System", "24 HE", "GC No. 41-077-92", "2005", "2007", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24", "24", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "96.9", "", "", "", "", "95.1"]} +{"pcdb_id": 10584, "brand_name": "Main", "model_name": "9 HE", "model_qualifier": "", "winter_efficiency_pct": 84.0, "summer_efficiency_pct": 76.4, "comparative_hot_water_efficiency_pct": 55.8, "output_kw_max": 8.82, "final_year_of_manufacture": 2011, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010584", "000005", "0", "2013/May/07 10:29", "Baxi Potterton", "Main", "9 HE", "", "GC No. 41-474-01", "2005", "2011", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "8.82", "8.82", "", "", "84.0", "76.4", "", "55.8", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "86.3", "90.9", "", "", "", "", "90.0"]} +{"pcdb_id": 10585, "brand_name": "Main", "model_name": "12 HE", "model_qualifier": "", "winter_efficiency_pct": 84.2, "summer_efficiency_pct": 76.6, "comparative_hot_water_efficiency_pct": 55.9, "output_kw_max": 11.78, "final_year_of_manufacture": 2011, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010585", "000005", "0", "2013/May/07 10:30", "Baxi Potterton", "Main", "12 HE", "", "GC No. 41-474-02", "2005", "2011", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "11.78", "11.78", "", "", "84.2", "76.6", "", "55.9", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "86.5", "91.3", "", "", "", "", "90.4"]} +{"pcdb_id": 10586, "brand_name": "Main", "model_name": "15 HE", "model_qualifier": "", "winter_efficiency_pct": 84.0, "summer_efficiency_pct": 76.4, "comparative_hot_water_efficiency_pct": 55.8, "output_kw_max": 14.76, "final_year_of_manufacture": 2011, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010586", "000005", "0", "2013/May/07 10:30", "Baxi Potterton", "Main", "15 HE", "", "GC No. 41-474-03", "2005", "2011", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "14.76", "14.76", "", "", "84.0", "76.4", "", "55.8", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "86.7", "90.7", "", "", "", "", "90.0"]} +{"pcdb_id": 10587, "brand_name": "Main", "model_name": "18 HE", "model_qualifier": "", "winter_efficiency_pct": 84.0, "summer_efficiency_pct": 76.4, "comparative_hot_water_efficiency_pct": 55.8, "output_kw_max": 17.72, "final_year_of_manufacture": 2011, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010587", "000005", "0", "2013/May/07 10:30", "Baxi Potterton", "Main", "18 HE", "", "GC No. 41-474-04", "2005", "2011", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "17.72", "17.72", "", "", "84.0", "76.4", "", "55.8", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "86.8", "90.6", "", "", "", "", "89.9"]} +{"pcdb_id": 10588, "brand_name": "Main", "model_name": "24 HE", "model_qualifier": "", "winter_efficiency_pct": 84.0, "summer_efficiency_pct": 76.4, "comparative_hot_water_efficiency_pct": 55.8, "output_kw_max": 23.63, "final_year_of_manufacture": 2011, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010588", "000005", "0", "2013/May/07 10:30", "Baxi Potterton", "Main", "24 HE", "", "GC No. 41-474-05", "2005", "2011", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "23.63", "23.63", "", "", "84.0", "76.4", "", "55.8", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "86.8", "90.6", "", "", "", "", "89.9"]} +{"pcdb_id": 10589, "brand_name": "Saunier Duval", "model_name": "Semia Condens F30E", "model_qualifier": "", "winter_efficiency_pct": 85.5, "summer_efficiency_pct": 76.9, "comparative_hot_water_efficiency_pct": 54.1, "output_kw_max": 28.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010589", "000206", "0", "2006/Jan/17 12:31", "Saunier Duval", "Saunier Duval", "Semia Condens F30E", "", "", "2005", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28.6", "28.6", "", "", "85.5", "76.9", "", "54.1", "", "2", "", "", "104", "1", "2", "150", "70", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.5", "90.6", "", "", "", "", "90.0"]} +{"pcdb_id": 10590, "brand_name": "Saunier Duval", "model_name": "Semia Condens F24E", "model_qualifier": "", "winter_efficiency_pct": 85.5, "summer_efficiency_pct": 76.9, "comparative_hot_water_efficiency_pct": 54.1, "output_kw_max": 24.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010590", "000206", "0", "2006/Jan/17 12:31", "Saunier Duval", "Saunier Duval", "Semia Condens F24E", "", "", "2005", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.5", "24.5", "", "", "85.5", "76.9", "", "54.1", "", "2", "", "", "104", "1", "2", "145", "75", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "86.3", "91.1", "", "", "", "", "90.2"]} +{"pcdb_id": 10591, "brand_name": "Gerkros", "model_name": "Termogas", "model_qualifier": "KT", "winter_efficiency_pct": 87.5, "summer_efficiency_pct": 78.5, "comparative_hot_water_efficiency_pct": 57.3, "output_kw_max": 21.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010591", "000245", "0", "2012/Mar/27 10:12", "Gerkros Boilers (Tipperary) Limited", "Gerkros", "Termogas", "KT", "", "2005", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "1", "21.6", "21.6", "", "", "87.5", "78.5", "", "57.3", "", "2", "", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "86.7", "96.0", "", "", "", "", "94.3"]} +{"pcdb_id": 10592, "brand_name": "Gerkros", "model_name": "Termogas", "model_qualifier": "KST", "winter_efficiency_pct": 84.7, "summer_efficiency_pct": 76.1, "comparative_hot_water_efficiency_pct": 53.5, "output_kw_max": 21.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010592", "000245", "0", "2005/Nov/30 11:26", "Gerkros Boilers (Tipperary) Limited", "Gerkros", "Termogas", "KST", "", "2005", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "1", "21.6", "21.6", "", "", "84.7", "76.1", "", "53.5", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "84.9", "90.8", "", "", "", "", "89.7"]} +{"pcdb_id": 10593, "brand_name": "Baxi", "model_name": "Platinum", "model_qualifier": "15 HE", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 15.24, "final_year_of_manufacture": 2007, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010593", "000005", "0", "2012/Mar/27 10:12", "Baxi Potterton", "Baxi", "Platinum", "15 HE", "GC No. 41-077-90", "2005", "2007", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "15.24", "15.24", "", "", "88.7", "79.7", "", "58.2", "", "2", "", "", "102", "1", "2", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.3", "97.7", "", "", "", "", "96.3"]} +{"pcdb_id": 10594, "brand_name": "Warmflow", "model_name": "Utility", "model_qualifier": "U90", "winter_efficiency_pct": 86.6, "summer_efficiency_pct": 74.9, "comparative_hot_water_efficiency_pct": 54.7, "output_kw_max": 26.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010594", "000063", "0", "2012/Mar/27 10:12", "Warmflow Engineering", "Warmflow", "Utility", "U90", "", "2005", "current", "4", "1", "1", "1", "0", "", "", "1", "3", "2", "15", "26", "", "", "86.6", "74.9", "", "54.7", "", "2", "", "", "201", "1", "1", "125", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.0", "88.5", "", "", "", "", "88.0"]} +{"pcdb_id": 10595, "brand_name": "Kidd VHE", "model_name": "2", "model_qualifier": "Natural Gas", "winter_efficiency_pct": 84.1, "summer_efficiency_pct": 76.5, "comparative_hot_water_efficiency_pct": 55.9, "output_kw_max": 45.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010595", "000204", "0", "2012/Mar/27 10:12", "Archie Kidd (Thermal)", "Kidd VHE", "2", "Natural Gas", "", "2005", "current", "1", "1", "1", "1", "0", "", "", "2", "3", "2", "29.3", "45.0", "", "", "84.1", "76.5", "", "55.9", "", "2", "", "", "101", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "86.5", "91.2", "", "", "", "", "90.3"]} +{"pcdb_id": 10596, "brand_name": "Trianco", "model_name": "Tristar Optima", "model_qualifier": "Junior K System 24 SB", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 25.0, "final_year_of_manufacture": 2007, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010596", "000062", "0", "2012/Mar/27 10:12", "Trianco", "Trianco", "Tristar Optima", "Junior K System 24 SB", "GC 47 897 06", "2005", "2007", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "25", "25", "", "", "88.1", "79.1", "", "57.8", "", "2", "1", "", "102", "1", "2", "135", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.7", "96.7", "", "", "", "", "95.2"]} +{"pcdb_id": 10597, "brand_name": "Trianco", "model_name": "Tristar Optima", "model_qualifier": "Junior K Combi 24 CB", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 55.9, "output_kw_max": 25.0, "final_year_of_manufacture": 2007, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010597", "000062", "0", "2009/Mar/24 12:05", "Trianco", "Trianco", "Tristar Optima", "Junior K Combi 24 CB", "GC 41 898 39", "2005", "2007", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "25", "25", "", "", "88.1", "79.5", "", "55.9", "", "2", "", "", "104", "1", "2", "135", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "0", "0", "0005", "", "", "", "", "", "", "", "", "88.7", "96.7", "", "", "", "", "95.2"]} +{"pcdb_id": 10598, "brand_name": "Grant", "model_name": "Vortex", "model_qualifier": "Outdoor Condensing Combi 36", "winter_efficiency_pct": 90.5, "summer_efficiency_pct": 84.4, "comparative_hot_water_efficiency_pct": 46.2, "output_kw_max": 36.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 1, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010598", "000048", "0", "2024/Jan/31 10:17", "Grant Engineering (UK)", "Grant", "Vortex", "Outdoor Condensing Combi 36", "", "2005", "current", "4", "1", "2", "2", "0", "", "", "2", "3", "2", "36", "36", "", "", "90.5", "84.4", "", "46.2", "", "2", "", "", "203", "1", "1", "", "", "1", "", "", "40", "0", "25", "3", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "95.1", "99.3", "", "", "", "", "98.5"]} +{"pcdb_id": 10599, "brand_name": "Grant", "model_name": "Vortex", "model_qualifier": "Outdoor Condensing Combi 26", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 83.0, "comparative_hot_water_efficiency_pct": 45.4, "output_kw_max": 26.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 1, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010599", "000048", "0", "2024/Jan/31 10:17", "Grant Engineering (UK)", "Grant", "Vortex", "Outdoor Condensing Combi 26", "", "2005", "current", "4", "1", "2", "2", "0", "", "", "2", "3", "2", "26", "26", "", "", "89.1", "83.0", "", "45.4", "", "2", "", "", "203", "1", "1", "", "", "1", "", "", "40", "0", "25", "3", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "93.6", "96.4", "", "", "", "", "95.9"]} +{"pcdb_id": 10600, "brand_name": "Firebird", "model_name": "Combipac C20", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 82.2, "comparative_hot_water_efficiency_pct": 45.0, "output_kw_max": 20.0, "final_year_of_manufacture": 2010, "subsidiary_type": 0, "store_type": 1, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010600", "000047", "0", "2024/Jan/31 10:17", "Firebird Boilers", "Firebird", "Combipac C20", "", "", "2005", "2010", "4", "1", "2", "2", "0", "", "", "2", "2", "1", "15", "20", "", "", "88.3", "82.2", "", "45.0", "", "2", "", "", "203", "1", "1", "138", "0", "1", "1", "0", "40", "0", "25", "1", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.7", "95.2", "", "", "", "", "94.5"]} +{"pcdb_id": 10601, "brand_name": "Firebird", "model_name": "Combipac C26", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 82.2, "comparative_hot_water_efficiency_pct": 45.0, "output_kw_max": 26.0, "final_year_of_manufacture": 2010, "subsidiary_type": 0, "store_type": 1, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010601", "000047", "0", "2024/Jan/31 10:17", "Firebird Boilers", "Firebird", "Combipac C26", "", "", "2005", "2010", "4", "1", "2", "2", "0", "", "", "2", "2", "1", "20", "26", "", "", "88.3", "82.2", "", "45.0", "", "2", "", "", "203", "1", "1", "138", "0", "1", "1", "0", "40", "0", "25", "1", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.5", "95.3", "", "", "", "", "94.6"]} +{"pcdb_id": 10602, "brand_name": "Firebird", "model_name": "Combipac C35", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 82.0, "comparative_hot_water_efficiency_pct": 44.9, "output_kw_max": 35.0, "final_year_of_manufacture": 2010, "subsidiary_type": 0, "store_type": 1, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010602", "000047", "0", "2024/Jan/31 10:17", "Firebird Boilers", "Firebird", "Combipac C35", "", "", "2005", "2010", "4", "1", "2", "2", "0", "", "", "2", "2", "1", "26", "35", "", "", "88.1", "82.0", "", "44.9", "", "2", "", "", "203", "1", "1", "138", "0", "1", "1", "0", "40", "0", "25", "1", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.4", "94.9", "", "", "", "", "94.2"]} +{"pcdb_id": 10603, "brand_name": "Firebird", "model_name": "Heatpac C20", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 58.8, "output_kw_max": 20.0, "final_year_of_manufacture": 2010, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010603", "000047", "0", "2012/Mar/27 10:12", "Firebird Boilers", "Firebird", "Heatpac C20", "", "", "2005", "2010", "4", "1", "2", "1", "0", "", "", "2", "2", "1", "15", "20", "", "", "88.3", "80.5", "", "58.8", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.7", "95.2", "", "", "", "", "94.5"]} +{"pcdb_id": 10604, "brand_name": "Firebird", "model_name": "Heatpac C26", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 58.8, "output_kw_max": 26.0, "final_year_of_manufacture": 2010, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010604", "000047", "0", "2012/Mar/27 10:12", "Firebird Boilers", "Firebird", "Heatpac C26", "", "", "2005", "2010", "4", "1", "2", "1", "0", "", "", "2", "2", "1", "20", "26", "", "", "88.3", "80.5", "", "58.8", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.5", "95.3", "", "", "", "", "94.6"]} +{"pcdb_id": 10605, "brand_name": "Firebird", "model_name": "Heatpac C35", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 58.7, "output_kw_max": 35.0, "final_year_of_manufacture": 2010, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010605", "000047", "0", "2012/Mar/27 10:12", "Firebird Boilers", "Firebird", "Heatpac C35", "", "", "2005", "2010", "4", "1", "2", "1", "0", "", "", "2", "2", "1", "26", "35", "", "", "88.1", "80.3", "", "58.7", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.4", "94.9", "", "", "", "", "94.2"]} +{"pcdb_id": 10606, "brand_name": "Firebird", "model_name": "System C20", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 58.8, "output_kw_max": 20.0, "final_year_of_manufacture": 2010, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010606", "000047", "0", "2012/Mar/27 10:12", "Firebird Boilers", "Firebird", "System C20", "", "", "2005", "2010", "4", "1", "1", "1", "0", "", "", "2", "2", "1", "15", "20", "", "", "88.3", "80.5", "", "58.8", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.7", "95.2", "", "", "", "", "94.5"]} +{"pcdb_id": 10607, "brand_name": "Firebird", "model_name": "System C26", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 58.8, "output_kw_max": 26.0, "final_year_of_manufacture": 2010, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010607", "000047", "0", "2012/Mar/27 10:12", "Firebird Boilers", "Firebird", "System C26", "", "", "2005", "2010", "4", "1", "1", "1", "0", "", "", "2", "2", "1", "20", "26", "", "", "88.3", "80.5", "", "58.8", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.5", "95.3", "", "", "", "", "94.6"]} +{"pcdb_id": 10608, "brand_name": "Firebird", "model_name": "System C35", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 58.7, "output_kw_max": 35.0, "final_year_of_manufacture": 2010, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010608", "000047", "0", "2012/Mar/27 10:12", "Firebird Boilers", "Firebird", "System C35", "", "", "2005", "2010", "4", "1", "1", "1", "0", "", "", "2", "2", "1", "26", "35", "", "", "88.1", "80.3", "", "58.7", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.4", "94.9", "", "", "", "", "94.2"]} +{"pcdb_id": 10609, "brand_name": "Firebird", "model_name": "Systempac C35", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 58.7, "output_kw_max": 35.0, "final_year_of_manufacture": 2010, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010609", "000047", "0", "2012/Mar/27 10:12", "Firebird Boilers", "Firebird", "Systempac C35", "", "", "2005", "2010", "4", "1", "2", "1", "0", "", "", "2", "2", "1", "26", "35", "", "", "88.1", "80.3", "", "58.7", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.4", "94.9", "", "", "", "", "94.2"]} +{"pcdb_id": 10610, "brand_name": "Firebird", "model_name": "Systempac C26", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 58.8, "output_kw_max": 26.0, "final_year_of_manufacture": 2010, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010610", "000047", "0", "2012/Mar/27 10:12", "Firebird Boilers", "Firebird", "Systempac C26", "", "", "2005", "2010", "4", "1", "2", "1", "0", "", "", "2", "2", "1", "20", "26", "", "", "88.3", "80.5", "", "58.8", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.5", "95.3", "", "", "", "", "94.6"]} +{"pcdb_id": 10611, "brand_name": "Firebird", "model_name": "Systempac C20", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 58.8, "output_kw_max": 20.0, "final_year_of_manufacture": 2010, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010611", "000047", "0", "2012/Mar/27 10:12", "Firebird Boilers", "Firebird", "Systempac C20", "", "", "2005", "2010", "4", "1", "2", "1", "0", "", "", "2", "2", "1", "15", "20", "", "", "88.3", "80.5", "", "58.8", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.7", "95.2", "", "", "", "", "94.5"]} +{"pcdb_id": 10612, "brand_name": "Halstead", "model_name": "Ace", "model_qualifier": "HE 24", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 55.9, "output_kw_max": 18.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010612", "000019", "0", "2006/Jan/30 20:19", "Halstead Boilers", "Halstead", "Ace", "HE 24", "4733319", "2005", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "18", "18", "", "", "88.2", "79.6", "", "55.9", "", "2", "", "", "104", "1", "2", "140", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "97.2", "", "", "", "", "95.5"]} +{"pcdb_id": 10613, "brand_name": "Halstead", "model_name": "Ace", "model_qualifier": "HE 30", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 56.0, "output_kw_max": 23.1, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010613", "000019", "0", "2006/Jan/30 20:19", "Halstead Boilers", "Halstead", "Ace", "HE 30", "4733320", "2005", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "23.1", "23.1", "", "", "88.2", "79.6", "", "56.0", "", "2", "", "", "104", "1", "2", "160", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "97.3", "", "", "", "", "95.5"]} +{"pcdb_id": 10614, "brand_name": "Ariston", "model_name": "ACO 35 HP MFFI", "model_qualifier": "ACO 35 HP MFFI", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 56.1, "output_kw_max": 29.4, "final_year_of_manufacture": 2007, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010614", "000080", "0", "2008/Jun/26 09:06", "Merloni TermoSanitari SpA", "Ariston", "ACO 35 HP MFFI", "ACO 35 HP MFFI", "GC No. 47-116-35", "2005", "2007", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "29.4", "29.4", "", "", "88.3", "79.7", "", "56.1", "", "2", "", "", "104", "1", "2", "148", "7", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.2", "97.5", "", "", "", "", "95.7"]} +{"pcdb_id": 10615, "brand_name": "Potterton", "model_name": "Promax FSB", "model_qualifier": "30 HE", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 30.18, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010615", "000005", "0", "2015/Aug/06 12:50", "Baxi Potterton", "Potterton", "Promax FSB", "30 HE", "GC No. 41-595-39", "2006", "2015", "1", "1", "1", "1", "0", "", "", "2", "2", "2", "30.18", "30.18", "", "", "88.1", "79.1", "", "57.8", "", "2", "", "", "102", "1", "2", "80", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.4", "96.4", "", "", "", "", "95.1"]} +{"pcdb_id": 10616, "brand_name": "Alpha", "model_name": "CD18S", "model_qualifier": "", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 78.9, "comparative_hot_water_efficiency_pct": 57.6, "output_kw_max": 18.0, "final_year_of_manufacture": 2007, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010616", "000001", "0", "2012/Mar/27 10:12", "Alpha Therm", "Alpha", "CD18S", "", "", "2005", "2007", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18", "18", "", "", "87.9", "78.9", "", "57.6", "", "2", "", "", "102", "1", "2", "125", "2", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.7", "96.2", "", "", "", "", "94.8"]} +{"pcdb_id": 10617, "brand_name": "Alpha", "model_name": "CD18S", "model_qualifier": "", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 18.0, "final_year_of_manufacture": 2007, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010617", "000001", "0", "2012/Mar/27 10:12", "Alpha Therm", "Alpha", "CD18S", "", "", "2005", "2007", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "18", "18", "", "", "88.9", "79.9", "", "58.4", "", "2", "1", "", "102", "1", "2", "125", "2", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.7", "98.4", "", "", "", "", "96.9"]} +{"pcdb_id": 10618, "brand_name": "Grant", "model_name": "Vortex", "model_qualifier": "Utility 46-58", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 81.1, "comparative_hot_water_efficiency_pct": 59.2, "output_kw_max": 60.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010618", "000048", "0", "2015/Sep/03 13:09", "Grant Engineering", "Grant", "Vortex", "Utility 46-58", "", "2006", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "46", "60", "", "", "88.9", "81.1", "", "59.2", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.5", "96.7", "", "", "", "", "95.7"]} +{"pcdb_id": 10619, "brand_name": "Grant", "model_name": "Vortex", "model_qualifier": "Utility 58-70", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 59.0, "output_kw_max": 70.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010619", "000048", "0", "2015/Sep/03 13:11", "Grant Engineering", "Grant", "Vortex", "Utility 58-70", "", "2006", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "60", "70", "", "", "88.6", "80.8", "", "59.0", "", "2", "", "", "201", "1", "1", "", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.9", "96.2", "", "", "", "", "95.2"]} +{"pcdb_id": 10620, "brand_name": "Viessmann", "model_name": "Vitodens 100 Compact", "model_qualifier": "WB1A 8-24kW", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 24.0, "final_year_of_manufacture": 2007, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010620", "000033", "0", "2012/Mar/27 10:12", "Viessmann", "Viessmann", "Vitodens 100 Compact", "WB1A 8-24kW", "41-819-10", "", "2007", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24", "24", "", "", "88.5", "79.5", "", "58.1", "", "2", "", "", "102", "1", "2", "51", "6", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.6", "97.8", "", "", "", "", "96.0"]} +{"pcdb_id": 10621, "brand_name": "Viessmann", "model_name": "Vitodens 100 Compact", "model_qualifier": "WB1A 8-18kW", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 18.0, "final_year_of_manufacture": 2007, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010621", "000033", "0", "2012/Mar/27 10:12", "Viessmann", "Viessmann", "Vitodens 100 Compact", "WB1A 8-18kW", "41-819-12", "", "2007", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18", "18", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "35", "6", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.5", "97.6", "", "", "", "", "95.8"]} +{"pcdb_id": 10622, "brand_name": "Sime", "model_name": "Format 80 C TS", "model_qualifier": "", "winter_efficiency_pct": 81.3, "summer_efficiency_pct": 71.2, "comparative_hot_water_efficiency_pct": 50.1, "output_kw_max": 23.7, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010622", "000213", "0", "2018/Feb/26 17:06", "Fonderie Sime S.p.A.", "Sime", "Format 80 C TS", "", "", "2006", "2018", "1", "2", "1", "2", "0", "", "", "1", "3", "2", "23.7", "23.7", "", "", "81.3", "71.2", "", "50.1", "", "2", "", "", "104", "1", "2", "120", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "83.9", "82.2", "", "", "", "", "82.5"]} +{"pcdb_id": 10623, "brand_name": "Sime", "model_name": "Format 80 C TS LPG", "model_qualifier": "", "winter_efficiency_pct": 83.1, "summer_efficiency_pct": 73.0, "comparative_hot_water_efficiency_pct": 51.3, "output_kw_max": 23.7, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010623", "000213", "0", "2018/Feb/26 17:07", "Fonderie Sime S.p.A.", "Sime", "Format 80 C TS LPG", "", "", "2006", "2018", "2", "2", "1", "2", "0", "", "", "1", "3", "2", "23.7", "23.7", "", "", "83.1", "73.0", "", "51.3", "", "2", "1", "", "104", "1", "2", "120", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "85.7", "84.0", "", "", "", "", "84.3"]} +{"pcdb_id": 10624, "brand_name": "Sime", "model_name": "Format 100 C TS", "model_qualifier": "", "winter_efficiency_pct": 82.1, "summer_efficiency_pct": 72.0, "comparative_hot_water_efficiency_pct": 50.6, "output_kw_max": 28.0, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010624", "000213", "0", "2018/Feb/26 16:59", "Fonderie Sime S.p.A.", "Sime", "Format 100 C TS", "", "", "2006", "2018", "1", "2", "1", "2", "0", "", "", "1", "3", "2", "28", "28.0", "", "", "82.1", "72.0", "", "50.6", "", "2", "", "", "104", "1", "2", "120", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "84.3", "83.6", "", "", "", "", "83.7"]} +{"pcdb_id": 10625, "brand_name": "Sime", "model_name": "Format 100 C TS LPG", "model_qualifier": "", "winter_efficiency_pct": 83.1, "summer_efficiency_pct": 73.0, "comparative_hot_water_efficiency_pct": 51.3, "output_kw_max": 28.0, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010625", "000213", "0", "2018/Feb/26 17:00", "Fonderie Sime S.p.A.", "Sime", "Format 100 C TS LPG", "", "", "2006", "2018", "2", "2", "1", "2", "0", "", "", "1", "3", "2", "28", "28.0", "", "", "83.1", "73.0", "", "51.3", "", "2", "1", "", "104", "1", "2", "120", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "86.2", "85.5", "", "", "", "", "85.6"]} +{"pcdb_id": 10626, "brand_name": "Sime", "model_name": "Format 110 C TS", "model_qualifier": "", "winter_efficiency_pct": 81.9, "summer_efficiency_pct": 71.8, "comparative_hot_water_efficiency_pct": 50.5, "output_kw_max": 32.4, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010626", "000213", "0", "2018/Feb/26 17:02", "Fonderie Sime S.p.A.", "Sime", "Format 110 C TS", "", "", "2006", "2018", "1", "2", "1", "2", "0", "", "", "1", "3", "2", "32.4", "32.4", "", "", "81.9", "71.8", "", "50.5", "", "2", "", "", "104", "1", "2", "165", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "84.0", "83.3", "", "", "", "", "83.5"]} +{"pcdb_id": 10627, "brand_name": "Sime", "model_name": "Format 110 C TS LPG", "model_qualifier": "", "winter_efficiency_pct": 83.1, "summer_efficiency_pct": 73.0, "comparative_hot_water_efficiency_pct": 51.3, "output_kw_max": 32.4, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010627", "000213", "0", "2018/Feb/26 17:02", "Fonderie Sime S.p.A.", "Sime", "Format 110 C TS LPG", "", "", "2006", "2018", "2", "2", "1", "2", "0", "", "", "1", "3", "2", "32.4", "32.4", "", "", "83.1", "73.0", "", "51.3", "", "2", "1", "", "104", "1", "2", "165", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "85.8", "85.2", "", "", "", "", "85.3"]} +{"pcdb_id": 10628, "brand_name": "Sime", "model_name": "Format System 24TS", "model_qualifier": "", "winter_efficiency_pct": 81.5, "summer_efficiency_pct": 70.8, "comparative_hot_water_efficiency_pct": 51.7, "output_kw_max": 23.7, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010628", "000213", "0", "2018/Feb/28 16:59", "Fonderie Sime S.p.A.", "Sime", "Format System 24TS", "", "", "2006", "2018", "1", "2", "1", "1", "0", "", "", "1", "3", "2", "23.7", "23.7", "", "", "81.5", "70.8", "", "51.7", "", "2", "", "", "102", "1", "2", "120", "10", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "83.9", "82.2", "", "", "", "", "82.5"]} +{"pcdb_id": 10629, "brand_name": "Sime", "model_name": "Format System 24TS LPG", "model_qualifier": "", "winter_efficiency_pct": 83.3, "summer_efficiency_pct": 72.6, "comparative_hot_water_efficiency_pct": 53.0, "output_kw_max": 23.7, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010629", "000213", "0", "2018/Feb/28 17:00", "Fonderie Sime S.p.A.", "Sime", "Format System 24TS LPG", "", "", "2006", "2018", "2", "2", "1", "1", "0", "", "", "1", "3", "2", "23.7", "23.7", "", "", "83.3", "72.6", "", "53.0", "", "2", "1", "", "102", "1", "2", "120", "10", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "85.7", "84.0", "", "", "", "", "84.3"]} +{"pcdb_id": 10631, "brand_name": "Sime", "model_name": "Format System 30TS", "model_qualifier": "", "winter_efficiency_pct": 82.3, "summer_efficiency_pct": 71.6, "comparative_hot_water_efficiency_pct": 52.3, "output_kw_max": 28.0, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010631", "000213", "0", "2018/Mar/05 14:05", "Fonderie Sime S.p.A.", "Sime", "Format System 30TS", "", "", "2006", "2018", "1", "2", "1", "1", "0", "", "", "1", "3", "2", "28.0", "28.0", "", "", "82.3", "71.6", "", "52.3", "", "2", "", "", "102", "1", "2", "120", "10", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "84.3", "83.6", "", "", "", "", "83.7"]} +{"pcdb_id": 10632, "brand_name": "Sime", "model_name": "Format System 30TS LPG", "model_qualifier": "", "winter_efficiency_pct": 83.3, "summer_efficiency_pct": 72.6, "comparative_hot_water_efficiency_pct": 53.0, "output_kw_max": 28.0, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010632", "000213", "0", "2018/Mar/05 14:06", "Fonderie Sime S.p.A.", "Sime", "Format System 30TS LPG", "", "", "2006", "2018", "2", "2", "1", "1", "0", "", "", "1", "3", "2", "28.0", "28.0", "", "", "83.3", "72.6", "", "53.0", "", "2", "1", "", "102", "1", "2", "120", "10", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "86.2", "85.5", "", "", "", "", "85.6"]} +{"pcdb_id": 10633, "brand_name": "Sime", "model_name": "Format System 35TS", "model_qualifier": "", "winter_efficiency_pct": 82.1, "summer_efficiency_pct": 71.4, "comparative_hot_water_efficiency_pct": 52.2, "output_kw_max": 32.4, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010633", "000213", "0", "2018/Mar/05 14:06", "Fonderie Sime S.p.A.", "Sime", "Format System 35TS", "", "", "2006", "2018", "1", "2", "1", "1", "0", "", "", "1", "3", "2", "32.4", "32.4", "", "", "82.1", "71.4", "", "52.2", "", "2", "", "", "102", "1", "2", "165", "10", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "84.0", "83.3", "", "", "", "", "83.5"]} +{"pcdb_id": 10634, "brand_name": "Sime", "model_name": "Format System 35TS LPG", "model_qualifier": "", "winter_efficiency_pct": 83.3, "summer_efficiency_pct": 72.6, "comparative_hot_water_efficiency_pct": 53.0, "output_kw_max": 32.4, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010634", "000213", "0", "2018/Mar/05 14:07", "Fonderie Sime S.p.A.", "Sime", "Format System 35TS LPG", "", "", "2006", "2018", "2", "2", "1", "1", "0", "", "", "1", "3", "2", "32.4", "32.4", "", "", "83.3", "72.6", "", "53.0", "", "2", "1", "", "102", "1", "2", "165", "10", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "85.8", "85.2", "", "", "", "", "85.3"]} +{"pcdb_id": 10635, "brand_name": "Sime", "model_name": "FE-25HE UK/1 N", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 56.3, "output_kw_max": 22.7, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010635", "000213", "0", "2018/Feb/26 16:51", "Fonderie Sime S.p.A.", "Sime", "FE-25HE UK/1 N", "", "", "2005", "2018", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "22.7", "22.7", "", "", "88.6", "80.0", "", "56.3", "", "2", "", "", "104", "1", "2", "50", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "98.4", "", "", "", "", "96.4"]} +{"pcdb_id": 10636, "brand_name": "Sime", "model_name": "FE-25HE UK/1 N", "model_qualifier": "", "winter_efficiency_pct": 89.6, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 57.0, "output_kw_max": 22.7, "final_year_of_manufacture": 2017, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010636", "000213", "0", "2018/Feb/26 16:52", "Fonderie Sime S.p.A.", "Sime", "FE-25HE UK/1 N", "", "", "2005", "2017", "2", "2", "1", "2", "0", "", "", "2", "3", "2", "22.7", "22.7", "", "", "89.6", "81.0", "", "57.0", "", "2", "1", "", "104", "1", "2", "50", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "", "", "0005", "", "", "", "", "", "", "", "", "89.8", "100.6", "", "", "", "", "98.5"]} +{"pcdb_id": 10637, "brand_name": "Sime", "model_name": "FE-30HE UK/1 N", "model_qualifier": "", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 56.6, "output_kw_max": 27.3, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010637", "000213", "0", "2018/Feb/26 16:53", "Fonderie Sime S.p.A.", "Sime", "FE-30HE UK/1 N", "", "", "2005", "2018", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "27.3", "27.3", "", "", "89.1", "80.5", "", "56.6", "", "2", "", "", "104", "1", "2", "50", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "", "", "0005", "", "", "", "", "", "", "", "", "88.2", "99.5", "", "", "", "", "97.3"]} +{"pcdb_id": 10638, "brand_name": "Sime", "model_name": "FE-30HE UK/1 N", "model_qualifier": "", "winter_efficiency_pct": 90.1, "summer_efficiency_pct": 81.5, "comparative_hot_water_efficiency_pct": 57.3, "output_kw_max": 27.3, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010638", "000213", "0", "2018/Feb/26 16:54", "Fonderie Sime S.p.A.", "Sime", "FE-30HE UK/1 N", "", "", "2005", "2018", "2", "2", "1", "2", "0", "", "", "2", "3", "2", "27.3", "27.3", "", "", "90.1", "81.5", "", "57.3", "", "2", "1", "", "104", "1", "2", "50", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "", "", "0005", "", "", "", "", "", "", "", "", "90.2", "101.7", "", "", "", "", "99.5"]} +{"pcdb_id": 10639, "brand_name": "Alpha", "model_name": "CD24C", "model_qualifier": "", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 56.6, "output_kw_max": 23.6, "final_year_of_manufacture": 2007, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010639", "000001", "0", "2011/Sep/06 13:09", "Alpha Therm", "Alpha", "CD24C", "", "", "2003", "2007", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "23.6", "23.6", "", "", "89.1", "80.5", "", "56.6", "", "2", "1", "", "104", "1", "2", "125", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "91.3", "98.5", "", "", "", "", "97.2"]} +{"pcdb_id": 10640, "brand_name": "Alpha", "model_name": "CD24S", "model_qualifier": "", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 23.6, "final_year_of_manufacture": 2007, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010640", "000001", "0", "2012/Mar/27 10:12", "Alpha Therm", "Alpha", "CD24S", "", "", "2003", "2007", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "23.6", "23.6", "", "", "89.1", "80.1", "", "58.5", "", "2", "1", "", "102", "1", "2", "125", "2", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "91.3", "98.5", "", "", "", "", "97.2"]} +{"pcdb_id": 10641, "brand_name": "Alpha", "model_name": "CD32C", "model_qualifier": "", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 80.6, "comparative_hot_water_efficiency_pct": 56.7, "output_kw_max": 32.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010641", "000001", "0", "2011/Sep/06 13:11", "Alpha Therm", "Alpha", "CD32C", "", "", "2003", "", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "32", "32", "", "", "89.2", "80.6", "", "56.7", "", "2", "1", "", "104", "1", "2", "140", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "91.1", "99.1", "", "", "", "", "97.6"]} +{"pcdb_id": 10642, "brand_name": "Alpha", "model_name": "CD50", "model_qualifier": "", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 82.0, "comparative_hot_water_efficiency_pct": 50.2, "output_kw_max": 32.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010642", "000001", "0", "2024/Jan/31 10:17", "Alpha Therm", "Alpha", "CD50", "", "", "2004", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "32", "32", "", "", "89.2", "82.0", "", "50.2", "", "2", "1", "", "106", "1", "2", "140", "2", "2", "2", "0", "52", "0", "25", "5", "60", "0.97", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "91.1", "98.9", "", "", "", "", "97.4"]} +{"pcdb_id": 10643, "brand_name": "Broag Remeha", "model_name": "Avanta Plus", "model_qualifier": "35c", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 56.5, "output_kw_max": 29.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010643", "000005", "0", "2012/Apr/11 14:49", "Remeha", "Broag Remeha", "Avanta Plus", "35c", "4767303", "2005", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "29.5", "29.5", "", "", "88.9", "80.3", "", "56.5", "", "2", "", "", "104", "1", "2", "115", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.5", "98.8", "", "", "", "", "96.9"]} +{"pcdb_id": 10644, "brand_name": "Gerkros", "model_name": "Gem fdc 80/105", "model_qualifier": "", "winter_efficiency_pct": 83.1, "summer_efficiency_pct": 71.4, "comparative_hot_water_efficiency_pct": 52.2, "output_kw_max": 30.77, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010644", "000245", "0", "2012/Mar/27 10:12", "Gerkros Boilers (Tipperary) Limited", "Gerkros", "Gem fdc 80/105", "", "", "1988", "current", "4", "1", "1", "1", "0", "", "", "1", "3", "2", "23.45", "30.77", "", "", "83.1", "71.4", "", "52.2", "", "2", "", "", "201", "1", "1", "250", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "83.0", "83.2", "", "", "", "", "83.2"]} +{"pcdb_id": 10646, "brand_name": "Gerkros", "model_name": "Cozy Mann 80/105 fdc", "model_qualifier": "", "winter_efficiency_pct": 83.1, "summer_efficiency_pct": 71.4, "comparative_hot_water_efficiency_pct": 52.2, "output_kw_max": 30.77, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010646", "000245", "0", "2012/Mar/27 10:12", "Gerkros Boilers (Tipperary) Limited", "Gerkros", "Cozy Mann 80/105 fdc", "", "", "1988", "current", "4", "1", "1", "1", "0", "", "", "1", "3", "2", "23.45", "30.77", "", "", "83.1", "71.4", "", "52.2", "", "2", "", "", "201", "1", "1", "250", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "83.0", "83.2", "", "", "", "", "83.2"]} +{"pcdb_id": 10647, "brand_name": "Gerkros", "model_name": "Gem fdc 50/70", "model_qualifier": "", "winter_efficiency_pct": 85.1, "summer_efficiency_pct": 73.4, "comparative_hot_water_efficiency_pct": 53.6, "output_kw_max": 20.51, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010647", "000245", "0", "2012/Mar/27 10:12", "Gerkros Boilers (Tipperary) Limited", "Gerkros", "Gem fdc 50/70", "", "", "1988", "current", "4", "1", "1", "1", "0", "", "", "1", "3", "2", "14.65", "20.51", "", "", "85.1", "73.4", "", "53.6", "", "2", "", "", "201", "1", "1", "250", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "83.1", "92.9", "", "", "", "", "91.0"]} +{"pcdb_id": 10648, "brand_name": "Gerkros", "model_name": "Cozy Mann 50/70 fdc", "model_qualifier": "", "winter_efficiency_pct": 85.1, "summer_efficiency_pct": 73.4, "comparative_hot_water_efficiency_pct": 53.6, "output_kw_max": 20.51, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010648", "000245", "0", "2012/Mar/27 10:12", "Gerkros Boilers (Tipperary) Limited", "Gerkros", "Cozy Mann 50/70 fdc", "", "", "1988", "current", "4", "1", "1", "1", "0", "", "", "1", "3", "2", "14.65", "20.51", "", "", "85.1", "73.4", "", "53.6", "", "2", "", "", "201", "1", "1", "250", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "83.1", "92.9", "", "", "", "", "91.0"]} +{"pcdb_id": 10649, "brand_name": "Gerkros", "model_name": "Gem Top Cleaner 60/95", "model_qualifier": "", "winter_efficiency_pct": 83.6, "summer_efficiency_pct": 71.9, "comparative_hot_water_efficiency_pct": 52.5, "output_kw_max": 27.84, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010649", "000245", "0", "2012/Mar/27 10:12", "Gerkros Boilers (Tipperary) Limited", "Gerkros", "Gem Top Cleaner 60/95", "", "", "1988", "current", "4", "1", "1", "1", "0", "", "", "1", "3", "2", "17.58", "27.84", "", "", "83.6", "71.9", "", "52.5", "", "2", "", "", "201", "1", "1", "250", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "84.3", "82.9", "", "", "", "", "83.2"]} +{"pcdb_id": 10650, "brand_name": "Gerkros", "model_name": "Gem Top Cleaner 90/120", "model_qualifier": "", "winter_efficiency_pct": 83.2, "summer_efficiency_pct": 71.5, "comparative_hot_water_efficiency_pct": 52.2, "output_kw_max": 35.17, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010650", "000245", "0", "2012/Mar/27 10:12", "Gerkros Boilers (Tipperary) Limited", "Gerkros", "Gem Top Cleaner 90/120", "", "", "1988", "current", "4", "1", "1", "1", "0", "", "", "1", "3", "2", "26.38", "35.17", "", "", "83.2", "71.5", "", "52.2", "", "2", "", "", "201", "1", "1", "250", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "83.4", "82.9", "", "", "", "", "83.0"]} +{"pcdb_id": 10651, "brand_name": "Gerkros", "model_name": "Gem Superior id 90/120", "model_qualifier": "", "winter_efficiency_pct": 83.2, "summer_efficiency_pct": 71.5, "comparative_hot_water_efficiency_pct": 52.2, "output_kw_max": 35.17, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010651", "000245", "0", "2012/Mar/27 10:12", "Gerkros Boilers (Tipperary) Limited", "Gerkros", "Gem Superior id 90/120", "", "", "1988", "current", "4", "1", "1", "1", "0", "", "", "1", "3", "2", "26.38", "35.17", "", "", "83.2", "71.5", "", "52.2", "", "2", "", "", "201", "1", "1", "250", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "83.4", "82.9", "", "", "", "", "83.0"]} +{"pcdb_id": 10652, "brand_name": "Gerkros", "model_name": "Cozy Mann 90/120 tdc", "model_qualifier": "", "winter_efficiency_pct": 83.2, "summer_efficiency_pct": 71.5, "comparative_hot_water_efficiency_pct": 52.2, "output_kw_max": 35.17, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010652", "000245", "0", "2012/Mar/27 10:12", "Gerkros Boilers (Tipperary) Limited", "Gerkros", "Cozy Mann 90/120 tdc", "", "", "1988", "current", "4", "1", "1", "1", "0", "", "", "1", "3", "2", "26.38", "35.17", "", "", "83.2", "71.5", "", "52.2", "", "2", "", "", "201", "1", "1", "250", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "83.4", "82.9", "", "", "", "", "83.0"]} +{"pcdb_id": 10653, "brand_name": "Gerkros", "model_name": "Cozy Mann 60/95 tdc", "model_qualifier": "", "winter_efficiency_pct": 83.6, "summer_efficiency_pct": 71.9, "comparative_hot_water_efficiency_pct": 52.5, "output_kw_max": 27.84, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["010653", "000245", "0", "2012/Mar/27 10:12", "Gerkros Boilers (Tipperary) Limited", "Gerkros", "Cozy Mann 60/95 tdc", "", "", "1988", "current", "4", "1", "1", "1", "0", "", "", "1", "3", "2", "17.58", "27.84", "", "", "83.6", "71.9", "", "52.5", "", "2", "", "", "201", "1", "1", "250", "0", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "84.3", "82.9", "", "", "", "", "83.2"]} +{"pcdb_id": 15001, "brand_name": "Mikrofill", "model_name": "Ethos", "model_qualifier": "36C", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 56.0, "output_kw_max": 27.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015001", "000226", "0", "2006/Apr/26 11:15", "Mikrofill Systems", "Mikrofill", "Ethos", "36C", "", "2005", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "27.6", "27.6", "", "", "88.3", "79.7", "", "56.0", "", "2", "", "", "104", "1", "2", "180", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.1", "97.4", "", "", "", "", "95.6"]} +{"pcdb_id": 15002, "brand_name": "Mikrofill", "model_name": "Ethos", "model_qualifier": "54C", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 56.1, "output_kw_max": 37.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015002", "000226", "0", "2006/Apr/26 11:15", "Mikrofill Systems", "Mikrofill", "Ethos", "54C", "", "2005", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "37.5", "37.5", "", "", "88.4", "79.8", "", "56.1", "", "2", "", "", "104", "1", "2", "200", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "97.8", "", "", "", "", "96.0"]} +{"pcdb_id": 15007, "brand_name": "Ideal", "model_name": "Icos", "model_qualifier": "HE30", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 30.1, "final_year_of_manufacture": 2011, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015007", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "Icos", "HE30", "41-399-10", "2006", "2011", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "30.1", "30.1", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "42", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.0", "97.5", "", "", "", "", "95.9"]} +{"pcdb_id": 15008, "brand_name": "Ideal", "model_name": "Icos", "model_qualifier": "HE36", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 37.0, "final_year_of_manufacture": 2011, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015008", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "Icos", "HE36", "41-399-16", "2006", "2011", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "37", "37", "", "", "88.9", "79.9", "", "58.3", "", "2", "", "", "102", "1", "2", "42", "", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.9", "98.6", "", "", "", "", "96.7"]} +{"pcdb_id": 15009, "brand_name": "Elco", "model_name": "Trigon 22", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 20.1, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015009", "000237", "0", "2012/Mar/27 10:12", "ELCO Klöckner Heiztechnik", "Elco", "Trigon 22", "", "", "2003", "current", "1", "1", "1", "1", "0", "", "", "2", "2", "2", "20.1", "20.1", "", "", "88.1", "79.1", "", "57.8", "", "2", "", "", "102", "1", "2", "137", "102", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.6", "97.3", "", "", "", "", "95.5"]} +{"pcdb_id": 15010, "brand_name": "Grant", "model_name": "Vortex", "model_qualifier": "15-26S Kitchen Boiler", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 81.3, "comparative_hot_water_efficiency_pct": 59.4, "output_kw_max": 26.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015010", "000048", "0", "2012/Mar/27 10:12", "Grant Engineering (UK)", "Grant", "Vortex", "15-26S Kitchen Boiler", "", "2002", "current", "4", "1", "1", "1", "0", "", "", "2", "2", "2", "15", "26", "", "", "89.1", "81.3", "", "59.4", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "93.6", "96.4", "", "", "", "", "95.9"]} +{"pcdb_id": 15011, "brand_name": "Grant", "model_name": "Vortex", "model_qualifier": "26-36 Utility Boiler", "winter_efficiency_pct": 90.5, "summer_efficiency_pct": 82.7, "comparative_hot_water_efficiency_pct": 60.4, "output_kw_max": 36.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015011", "000048", "0", "2012/Mar/27 10:12", "Grant Engineering (UK)", "Grant", "Vortex", "26-36 Utility Boiler", "", "2003", "current", "4", "1", "1", "1", "0", "", "", "2", "2", "2", "26", "36", "", "", "90.5", "82.7", "", "60.4", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "95.1", "99.3", "", "", "", "", "98.5"]} +{"pcdb_id": 15012, "brand_name": "Grant", "model_name": "Vortex", "model_qualifier": "26-36-S Utility System Boiler", "winter_efficiency_pct": 90.5, "summer_efficiency_pct": 82.7, "comparative_hot_water_efficiency_pct": 60.4, "output_kw_max": 36.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015012", "000048", "0", "2012/Mar/27 10:12", "Grant Engineering (UK)", "Grant", "Vortex", "26-36-S Utility System Boiler", "", "2003", "current", "4", "1", "1", "1", "0", "", "", "2", "2", "2", "26", "36", "", "", "90.5", "82.7", "", "60.4", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "95.1", "99.3", "", "", "", "", "98.5"]} +{"pcdb_id": 15013, "brand_name": "Grant", "model_name": "Vortex", "model_qualifier": "15-26 Kitchen Boiler", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 81.3, "comparative_hot_water_efficiency_pct": 59.4, "output_kw_max": 26.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015013", "000048", "0", "2012/Mar/27 10:12", "Grant Engineering (UK)", "Grant", "Vortex", "15-26 Kitchen Boiler", "", "2002", "current", "4", "1", "1", "1", "0", "", "", "2", "2", "2", "15", "26", "", "", "89.1", "81.3", "", "59.4", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "93.6", "96.4", "", "", "", "", "95.9"]} +{"pcdb_id": 15014, "brand_name": "Elco", "model_name": "Straton 22", "model_qualifier": "", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 21.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015014", "000237", "0", "2012/Mar/27 10:12", "ELCO Klöckner Heiztechnik", "Elco", "Straton 22", "", "", "1997", "current", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "12.1", "21.5", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "190", "2.5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "93.7", "98.4", "", "", "", "", "97.5"]} +{"pcdb_id": 15015, "brand_name": "Elco", "model_name": "Systron 2-22", "model_qualifier": "", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 22.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015015", "000237", "0", "2012/Mar/27 10:12", "ELCO Klöckner Heiztechnik", "Elco", "Systron 2-22", "", "", "1997", "current", "4", "1", "1", "1", "0", "", "", "1", "1", "2", "15", "22", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "189", "2.5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "88.3", "89.2", "", "", "", "", "89.0"]} +{"pcdb_id": 15016, "brand_name": "Glow-worm", "model_name": "Flexicom 12hx", "model_qualifier": "", "winter_efficiency_pct": 87.8, "summer_efficiency_pct": 78.8, "comparative_hot_water_efficiency_pct": 57.6, "output_kw_max": 12.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015016", "000207", "0", "2012/Mar/27 10:12", "Vaillant Group", "Glow-worm", "Flexicom 12hx", "", "GC 41-315-28", "2006", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "12.0", "12.0", "", "", "87.8", "78.8", "", "57.6", "", "2", "", "", "102", "1", "2", "60", "6", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0085", "", "", "", "", "", "", "", "", "89.6", "95.7", "", "", "", "", "94.5"]} +{"pcdb_id": 15017, "brand_name": "Glow-worm", "model_name": "Flexicom 15hx", "model_qualifier": "", "winter_efficiency_pct": 87.8, "summer_efficiency_pct": 78.8, "comparative_hot_water_efficiency_pct": 57.6, "output_kw_max": 15.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015017", "000207", "0", "2012/Mar/27 10:12", "Vaillant Group", "Glow-worm", "Flexicom 15hx", "", "GC 41-315-29", "2006", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "15.0", "15.0", "", "", "87.8", "78.8", "", "57.6", "", "2", "", "", "102", "1", "2", "60", "6", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.4", "95.7", "", "", "", "", "94.5"]} +{"pcdb_id": 15018, "brand_name": "Glow-worm", "model_name": "Flexicom 18hx", "model_qualifier": "", "winter_efficiency_pct": 87.7, "summer_efficiency_pct": 78.7, "comparative_hot_water_efficiency_pct": 57.5, "output_kw_max": 18.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015018", "000207", "0", "2012/Mar/27 10:12", "Vaillant Group", "Glow-worm", "Flexicom 18hx", "", "GC 41-315-42", "2006", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18.0", "18.0", "", "", "87.7", "78.7", "", "57.5", "", "2", "", "", "102", "1", "2", "60", "6", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0085", "", "", "", "", "", "", "", "", "89.0", "95.7", "", "", "", "", "94.4"]} +{"pcdb_id": 15019, "brand_name": "Glow-worm", "model_name": "Flexicom 24hx", "model_qualifier": "", "winter_efficiency_pct": 87.7, "summer_efficiency_pct": 78.7, "comparative_hot_water_efficiency_pct": 57.5, "output_kw_max": 24.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015019", "000207", "0", "2012/Mar/27 10:12", "Vaillant Group", "Glow-worm", "Flexicom 24hx", "", "GC 41-315-61", "2006", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24.0", "24.0", "", "", "87.7", "78.7", "", "57.5", "", "2", "", "", "102", "1", "2", "60", "6", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0085", "", "", "", "", "", "", "", "", "88.8", "95.7", "", "", "", "", "94.4"]} +{"pcdb_id": 15020, "brand_name": "Glow-worm", "model_name": "Flexicom 30hx", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 30.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015020", "000207", "0", "2012/Mar/27 10:12", "Vaillant Group", "Glow-worm", "Flexicom 30hx", "", "GC 41-315-67", "2006", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "30.0", "30.0", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "60", "6", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0085", "", "", "", "", "", "", "", "", "87.7", "97.0", "", "", "", "", "95.3"]} +{"pcdb_id": 15021, "brand_name": "Glow-worm", "model_name": "Flexicom 18sx", "model_qualifier": "", "winter_efficiency_pct": 87.7, "summer_efficiency_pct": 78.7, "comparative_hot_water_efficiency_pct": 57.5, "output_kw_max": 18.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015021", "000207", "0", "2012/Mar/27 10:12", "Vaillant Group", "Glow-worm", "Flexicom 18sx", "", "GC 41-315-72", "2006", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18.0", "18.0", "", "", "87.7", "78.7", "", "57.5", "", "2", "", "", "102", "1", "2", "180", "6", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.9", "95.7", "", "", "", "", "94.4"]} +{"pcdb_id": 15022, "brand_name": "Glow-worm", "model_name": "Flexicom 30sx", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 30.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015022", "000207", "0", "2012/Mar/27 10:12", "Vaillant Group", "Glow-worm", "Flexicom 30sx", "", "GC 41-047-76", "2006", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "30.0", "30.0", "", "", "88.1", "79.1", "", "57.8", "", "2", "", "", "102", "1", "2", "180", "6", "0", "", "0", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "97.0", "", "", "", "", "95.3"]} +{"pcdb_id": 15023, "brand_name": "Glow-worm", "model_name": "Flexicom 24cx", "model_qualifier": "", "winter_efficiency_pct": 87.8, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 55.7, "output_kw_max": 18.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015023", "000207", "0", "2010/Oct/22 10:39", "Vaillant Group", "Glow-worm", "Flexicom 24cx", "", "GC 47-047-33", "2006", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "18.0", "18.0", "", "", "87.8", "79.2", "", "55.7", "", "2", "", "", "104", "1", "2", "180", "6", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0085", "", "", "", "", "", "", "", "", "88.7", "96.0", "", "", "", "", "94.7"]} +{"pcdb_id": 15024, "brand_name": "Glow-worm", "model_name": "Flexicom 30cx", "model_qualifier": "", "winter_efficiency_pct": 87.7, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 55.7, "output_kw_max": 24.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015024", "000207", "0", "2010/Oct/22 10:40", "Vaillant Group", "Glow-worm", "Flexicom 30cx", "", "GC 47-047-34", "2006", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.0", "24.0", "", "", "87.7", "79.1", "", "55.7", "", "2", "", "", "104", "1", "2", "180", "6", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0085", "", "", "", "", "", "", "", "", "88.2", "96.0", "", "", "", "", "94.6"]} +{"pcdb_id": 15025, "brand_name": "Gerkros", "model_name": "Termogas KT/A", "model_qualifier": "", "winter_efficiency_pct": 87.7, "summer_efficiency_pct": 78.7, "comparative_hot_water_efficiency_pct": 57.5, "output_kw_max": 21.9, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015025", "000245", "0", "2012/Mar/27 10:12", "Gerkros Boilers (Tipperary) Limited", "Gerkros", "Termogas KT/A", "", "", "2005", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "1", "21.9", "21.9", "", "", "87.7", "78.7", "", "57.5", "", "2", "", "", "102", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "96.1", "", "", "", "", "94.6"]} +{"pcdb_id": 15027, "brand_name": "Baxi", "model_name": "Megaflo System", "model_qualifier": "24 HE", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 24.0, "final_year_of_manufacture": 2008, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015027", "000005", "0", "2012/Mar/27 10:12", "Baxi Heating", "Baxi", "Megaflo System", "24 HE", "GC No. 47-075-47", "2006", "2008", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24.0", "24.0", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "150", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "96.9", "", "", "", "", "95.2"]} +{"pcdb_id": 15028, "brand_name": "Baxi", "model_name": "Megaflo System", "model_qualifier": "28 HE", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 78.9, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 28.0, "final_year_of_manufacture": 2008, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015028", "000005", "0", "2012/Mar/27 10:12", "Baxi Heating", "Baxi", "Megaflo System", "28 HE", "GC No. 47-075-48", "2006", "2008", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "28.0", "28.0", "", "", "87.9", "78.9", "", "57.7", "", "2", "", "", "102", "1", "2", "150", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "96.7", "", "", "", "", "95.0"]} +{"pcdb_id": 15029, "brand_name": "Baxi", "model_name": "Duo-tec Combi", "model_qualifier": "24 HE", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 55.8, "output_kw_max": 24.0, "final_year_of_manufacture": 2008, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015029", "000005", "0", "2010/Nov/19 09:05", "Baxi Heating", "Baxi", "Duo-tec Combi", "24 HE", "GC No. 47-075-23", "2006", "2008", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.0", "24.0", "", "", "88.0", "79.4", "", "55.8", "", "2", "", "", "104", "1", "2", "155", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "96.9", "", "", "", "", "95.2"]} +{"pcdb_id": 15030, "brand_name": "Baxi", "model_name": "Duo-tec Combi", "model_qualifier": "28 HE", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 55.8, "output_kw_max": 24.0, "final_year_of_manufacture": 2008, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015030", "000005", "0", "2010/Nov/19 09:05", "Baxi Heating", "Baxi", "Duo-tec Combi", "28 HE", "GC No. 47-075-25", "2006", "2008", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.0", "24.0", "", "", "88.0", "79.4", "", "55.8", "", "2", "", "", "104", "1", "2", "155", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "96.9", "", "", "", "", "95.2"]} +{"pcdb_id": 15031, "brand_name": "Baxi", "model_name": "Duo-tec Combi", "model_qualifier": "33 HE", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 55.8, "output_kw_max": 28.0, "final_year_of_manufacture": 2008, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015031", "000005", "0", "2010/Nov/19 09:05", "Baxi Heating", "Baxi", "Duo-tec Combi", "33 HE", "GC No. 47-075-24", "2006", "2008", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28.0", "28.0", "", "", "87.9", "79.3", "", "55.8", "", "2", "", "", "104", "1", "2", "160", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "96.7", "", "", "", "", "95.0"]} +{"pcdb_id": 15032, "brand_name": "Baxi", "model_name": "Solo", "model_qualifier": "15 HE", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 15.24, "final_year_of_manufacture": 2010, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015032", "000005", "0", "2020/Dec/07 11:55", "Baxi Heating", "Baxi", "Solo", "15 HE", "GC No. 41-075-46", "2006", "2010", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "15.24", "15.24", "", "", "88.7", "79.7", "", "58.2", "", "2", "", "", "102", "1", "2", "80", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.3", "97.7", "", "", "", "", "96.3"]} +{"pcdb_id": 15033, "brand_name": "Baxi", "model_name": "Solo", "model_qualifier": "24 HE", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 22.0, "final_year_of_manufacture": 2010, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015033", "000005", "0", "2020/Dec/07 11:56", "Baxi Heating", "Baxi", "Solo", "24 HE", "GC No. 41-075-45", "2006", "2010", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "22.0", "22.0", "", "", "88.1", "79.1", "", "57.8", "", "2", "", "", "102", "1", "2", "80", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.5", "96.5", "", "", "", "", "95.2"]} +{"pcdb_id": 15034, "brand_name": "Baxi", "model_name": "Solo", "model_qualifier": "30 HE", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 30.18, "final_year_of_manufacture": 2010, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015034", "000005", "0", "2020/Dec/07 12:08", "Baxi Heating", "Baxi", "Solo", "30 HE", "GC No. 41-075-44", "2006", "2010", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "30.18", "30.18", "", "", "88.1", "79.1", "", "57.8", "", "2", "", "", "102", "1", "2", "80", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.4", "96.4", "", "", "", "", "95.1"]} +{"pcdb_id": 15035, "brand_name": "ATAG", "model_name": "Q25C", "model_qualifier": "", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 56.3, "output_kw_max": 21.9, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015035", "000227", "0", "2013/Oct/23 12:56", "ATAG Verwarming Nederland BV", "ATAG", "Q25C", "", "", "2006", "current", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "21.9", "21.9", "", "", "88.7", "80.1", "", "56.3", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.1", "98.6", "", "", "", "", "96.6"]} +{"pcdb_id": 15036, "brand_name": "ATAG", "model_name": "Q38C", "model_qualifier": "", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 56.4, "output_kw_max": 33.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015036", "000227", "0", "2013/Oct/23 12:57", "ATAG Verwarming Nederland BV", "ATAG", "Q38C", "", "", "2006", "current", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "33.3", "33.3", "", "", "88.7", "80.1", "", "56.4", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "98.7", "", "", "", "", "96.7"]} +{"pcdb_id": 15037, "brand_name": "ATAG", "model_name": "Q51C", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 56.4, "output_kw_max": 44.7, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015037", "000227", "0", "2013/Oct/23 12:57", "ATAG Verwarming Nederland BV", "ATAG", "Q51C", "", "", "2006", "current", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "44.7", "44.7", "", "", "88.8", "80.2", "", "56.4", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "98.8", "", "", "", "", "96.8"]} +{"pcdb_id": 15038, "brand_name": "ATAG", "model_name": "Q25S", "model_qualifier": "", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 21.9, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015038", "000227", "0", "2013/Oct/23 12:57", "ATAG Verwarming Nederland BV", "ATAG", "Q25S", "", "", "2006", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "21.9", "21.9", "", "", "88.9", "79.9", "", "58.3", "", "2", "", "", "102", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.2", "98.9", "", "", "", "", "96.9"]} +{"pcdb_id": 15039, "brand_name": "ATAG", "model_name": "Q38S", "model_qualifier": "", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 33.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015039", "000227", "0", "2013/Oct/23 12:57", "ATAG Verwarming Nederland BV", "ATAG", "Q38S", "", "", "2006", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "33.3", "33.3", "", "", "88.7", "79.7", "", "58.3", "", "2", "", "", "102", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "98.7", "", "", "", "", "96.7"]} +{"pcdb_id": 15040, "brand_name": "ATAG", "model_name": "Q51S", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 44.7, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015040", "000227", "0", "2013/Oct/23 12:57", "ATAG Verwarming Nederland BV", "ATAG", "Q51S", "", "", "2006", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "44.7", "44.7", "", "", "88.8", "79.8", "", "58.3", "", "2", "", "", "102", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "98.8", "", "", "", "", "96.8"]} +{"pcdb_id": 15041, "brand_name": "ATAG", "model_name": "Q60S", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 52.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015041", "000227", "0", "2013/Oct/23 12:57", "ATAG Verwarming Nederland BV", "ATAG", "Q60S", "", "", "2006", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "52.5", "52.5", "", "", "88.8", "79.8", "", "58.3", "", "2", "", "", "102", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "98.8", "", "", "", "", "96.8"]} +{"pcdb_id": 15042, "brand_name": "Halstead", "model_name": "Club HE 18", "model_qualifier": "", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 18.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015042", "000019", "0", "2012/Mar/27 10:12", "Halstead Boilers", "Halstead", "Club HE 18", "", "GC No 41-260-20", "2006", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "18", "18", "", "", "88.2", "79.2", "", "57.8", "", "2", "", "", "102", "1", "2", "106", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "97.2", "", "", "", "", "95.5"]} +{"pcdb_id": 15043, "brand_name": "Alpha", "model_name": "CD13R", "model_qualifier": "", "winter_efficiency_pct": 87.8, "summer_efficiency_pct": 78.8, "comparative_hot_water_efficiency_pct": 57.6, "output_kw_max": 12.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015043", "000001", "0", "2012/Mar/27 10:12", "Alpha Therm", "Alpha", "CD13R", "", "", "2005", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "12.0", "12.0", "", "", "87.8", "78.8", "", "57.6", "", "2", "", "", "102", "1", "2", "55", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "96.4", "", "", "", "", "94.8"]} +{"pcdb_id": 15046, "brand_name": "Alpha", "model_name": "CD30S", "model_qualifier": "", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 78.9, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 27.6, "final_year_of_manufacture": 2007, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015046", "000001", "0", "2012/Mar/27 10:12", "Alpha Therm", "Alpha", "CD30S", "", "", "2005", "2007", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "27.6", "27.6", "", "", "87.9", "78.9", "", "57.7", "", "2", "", "", "102", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.5", "96.4", "", "", "", "", "94.9"]} +{"pcdb_id": 15048, "brand_name": "Alpha", "model_name": "CD13R", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 12.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015048", "000001", "0", "2012/Mar/27 10:12", "Alpha Therm", "Alpha", "CD13R", "", "", "2005", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "12.0", "12.0", "", "", "88.8", "79.8", "", "58.3", "", "2", "1", "", "102", "1", "2", "55", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.7", "98.5", "", "", "", "", "96.9"]} +{"pcdb_id": 15049, "brand_name": "Alpha", "model_name": "CD24R", "model_qualifier": "", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 78.9, "comparative_hot_water_efficiency_pct": 57.6, "output_kw_max": 23.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015049", "000001", "0", "2012/Mar/27 10:12", "Alpha Therm", "Alpha", "CD24R", "", "", "2005", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "23.5", "23.5", "", "", "87.9", "78.9", "", "57.6", "", "2", "", "", "102", "1", "2", "55", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.2", "96.4", "", "", "", "", "94.8"]} +{"pcdb_id": 15050, "brand_name": "Alpha", "model_name": "CD24R", "model_qualifier": "", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 23.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015050", "000001", "0", "2012/Mar/27 10:12", "Alpha Therm", "Alpha", "CD24R", "", "", "2005", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "23.5", "23.5", "", "", "88.9", "79.9", "", "58.3", "", "2", "1", "", "102", "1", "2", "55", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.2", "98.5", "", "", "", "", "97.0"]} +{"pcdb_id": 15051, "brand_name": "Rotex", "model_name": "A1 BO 35i", "model_qualifier": "", "winter_efficiency_pct": 87.5, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 35.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015051", "000246", "0", "2013/Sep/19 14:23", "Rotex Heating Systems", "Rotex", "A1 BO 35i", "", "", "1998", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "25", "35", "", "", "87.5", "79.7", "", "58.2", "", "2", "", "", "201", "1", "1", "250", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.3", "93.7", "", "", "", "", "93.1"]} +{"pcdb_id": 15052, "brand_name": "Rotex", "model_name": "GCU 25", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 37.7, "output_kw_max": 25.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015052", "000246", "0", "2024/Jan/31 10:17", "Rotex Heating Systems", "Rotex", "GCU 25", "", "", "2005", "current", "1", "1", "1", "2", "0", "", "", "2", "3", "2", "25", "25", "", "", "88.1", "80.8", "", "37.7", "", "2", "", "", "106", "1", "2", "45", "7.7", "2", "1", "0", "500", "0", "80", "2", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "97.0", "", "", "", "", "95.4"]} +{"pcdb_id": 15053, "brand_name": "Rotex", "model_name": "GCU 25 F", "model_qualifier": "", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 81.9, "comparative_hot_water_efficiency_pct": 38.2, "output_kw_max": 25.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015053", "000246", "0", "2024/Jan/31 10:17", "Rotex Heating Systems", "Rotex", "GCU 25 F", "", "", "2005", "current", "2", "1", "1", "2", "0", "", "", "2", "3", "2", "25", "25", "", "", "89.2", "81.9", "", "38.2", "", "2", "0", "", "106", "1", "2", "45", "7.7", "2", "1", "0", "500", "0", "80", "2", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.7", "97.4", "", "", "", "", "95.8"]} +{"pcdb_id": 15054, "brand_name": "Rotex", "model_name": "GCU 35", "model_qualifier": "", "winter_efficiency_pct": 87.7, "summer_efficiency_pct": 80.4, "comparative_hot_water_efficiency_pct": 37.6, "output_kw_max": 35.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015054", "000246", "0", "2024/Jan/31 10:17", "Rotex Heating Systems", "Rotex", "GCU 35", "", "", "2005", "current", "1", "1", "1", "2", "0", "", "", "2", "3", "2", "35", "35", "", "", "87.7", "80.4", "", "37.6", "", "2", "", "", "106", "1", "2", "45", "7.7", "2", "1", "0", "500", "0", "80", "2", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "0", "", "0005", "", "", "", "", "", "", "", "", "86.9", "96.6", "", "", "", "", "94.7"]} +{"pcdb_id": 15055, "brand_name": "Rotex", "model_name": "GCU 35 F", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 81.2, "comparative_hot_water_efficiency_pct": 37.9, "output_kw_max": 35.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015055", "000246", "0", "2024/Jan/31 10:17", "Rotex Heating Systems", "Rotex", "GCU 35 F", "", "", "2005", "current", "2", "1", "1", "2", "0", "", "", "2", "3", "2", "35", "35", "", "", "88.5", "81.2", "", "37.9", "", "2", "0", "", "106", "1", "2", "45", "7.7", "2", "1", "0", "500", "0", "80", "2", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "0", "", "0005", "", "", "", "", "", "", "", "", "87.2", "97.0", "", "", "", "", "95.1"]} +{"pcdb_id": 15056, "brand_name": "Rotex", "model_name": "GSU 25", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 37.7, "output_kw_max": 25.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015056", "000246", "0", "2024/Jan/31 10:17", "Rotex Heating Systems", "Rotex", "GSU 25", "", "", "2005", "current", "1", "1", "1", "2", "0", "", "", "2", "3", "2", "25", "25", "", "", "88.1", "80.8", "", "37.7", "", "2", "", "", "106", "1", "2", "45", "7.7", "2", "1", "0", "500", "0", "80", "2", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "97.0", "", "", "", "", "95.4"]} +{"pcdb_id": 15057, "brand_name": "Rotex", "model_name": "GSU 25 F", "model_qualifier": "", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 81.9, "comparative_hot_water_efficiency_pct": 38.2, "output_kw_max": 25.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015057", "000246", "0", "2024/Jan/31 10:17", "Rotex Heating Systems", "Rotex", "GSU 25 F", "", "", "2005", "current", "2", "1", "1", "2", "0", "", "", "2", "3", "2", "25", "25", "", "", "89.2", "81.9", "", "38.2", "", "2", "0", "", "106", "1", "2", "45", "7.7", "2", "1", "0", "500", "0", "80", "2", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "0", "", "0005", "", "", "", "", "", "", "", "", "88.7", "97.4", "", "", "", "", "95.8"]} +{"pcdb_id": 15058, "brand_name": "Rotex", "model_name": "GSU 35", "model_qualifier": "", "winter_efficiency_pct": 87.7, "summer_efficiency_pct": 80.4, "comparative_hot_water_efficiency_pct": 37.6, "output_kw_max": 35.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015058", "000246", "0", "2024/Jan/31 10:17", "Rotex Heating Systems", "Rotex", "GSU 35", "", "", "2005", "current", "1", "1", "1", "2", "0", "", "", "2", "3", "2", "35", "35", "", "", "87.7", "80.4", "", "37.6", "", "2", "", "", "106", "1", "2", "45", "7.7", "2", "1", "0", "500", "0", "80", "2", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "0", "", "0005", "", "", "", "", "", "", "", "", "86.9", "96.6", "", "", "", "", "94.7"]} +{"pcdb_id": 15059, "brand_name": "Rotex", "model_name": "GSU 35 F", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 81.2, "comparative_hot_water_efficiency_pct": 37.9, "output_kw_max": 35.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015059", "000246", "0", "2024/Jan/31 10:17", "Rotex Heating Systems", "Rotex", "GSU 35 F", "", "", "2005", "current", "2", "1", "1", "2", "0", "", "", "2", "3", "2", "35", "35", "", "", "88.5", "81.2", "", "37.9", "", "2", "0", "", "106", "1", "2", "45", "7.7", "2", "1", "0", "500", "0", "80", "2", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.2", "97.0", "", "", "", "", "95.1"]} +{"pcdb_id": 15060, "brand_name": "SARIgas", "model_name": "EcoTop", "model_qualifier": "ETF 28A", "winter_efficiency_pct": 85.6, "summer_efficiency_pct": 77.0, "comparative_hot_water_efficiency_pct": 54.1, "output_kw_max": 26.9, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015060", "000244", "0", "2006/Jul/31 12:50", "SARIgas", "SARIgas", "EcoTop", "ETF 28A", "", "2006", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "26.9", "26.9", "", "", "85.6", "77.0", "", "54.1", "", "2", "", "", "104", "1", "2", "130", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "86.7", "91.2", "", "", "", "", "90.3"]} +{"pcdb_id": 15061, "brand_name": "SARIgas", "model_name": "EcoTop", "model_qualifier": "ETF 28A MA", "winter_efficiency_pct": 85.6, "summer_efficiency_pct": 77.0, "comparative_hot_water_efficiency_pct": 54.1, "output_kw_max": 26.9, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015061", "000244", "0", "2006/Jul/31 12:50", "SARIgas", "SARIgas", "EcoTop", "ETF 28A MA", "", "2006", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "26.9", "26.9", "", "", "85.6", "77.0", "", "54.1", "", "2", "", "", "104", "1", "2", "130", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "86.7", "91.2", "", "", "", "", "90.3"]} +{"pcdb_id": 15062, "brand_name": "Potterton", "model_name": "Promax HE Store", "model_qualifier": "90 Litre", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 52.3, "output_kw_max": 24.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015062", "000005", "0", "2024/Jan/31 10:17", "Baxi Heating", "Potterton", "Promax HE Store", "90 Litre", "GC No. 41-601-24", "2006", "2015", "1", "1", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "87.9", "80.8", "", "52.3", "", "2", "", "", "106", "1", "2", "166", "", "2", "2", "0", "90", "0", "45", "2", "60", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.2", "96.9", "", "", "", "", "95.0"]} +{"pcdb_id": 15063, "brand_name": "Potterton", "model_name": "Promax HE Store", "model_qualifier": "115 Litre", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 50.4, "output_kw_max": 24.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015063", "000005", "0", "2024/Jan/31 10:17", "Baxi Heating", "Potterton", "Promax HE Store", "115 Litre", "GC No. 41-591-76", "2006", "2015", "1", "1", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "87.9", "80.8", "", "50.4", "", "2", "", "", "106", "1", "2", "166", "", "2", "2", "0", "115", "0", "45", "2", "60", "", "0", "", "", "", "", "", "", "", "", "", "0", "0", "", "0005", "", "", "", "", "", "", "", "", "87.2", "96.9", "", "", "", "", "95.0"]} +{"pcdb_id": 15064, "brand_name": "Potterton", "model_name": "Promax HE Store", "model_qualifier": "150 Litre", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 80.9, "comparative_hot_water_efficiency_pct": 47.0, "output_kw_max": 24.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015064", "000005", "0", "2024/Jan/31 10:17", "Baxi Heating", "Potterton", "Promax HE Store", "150 Litre", "GC No 41-591-77", "2006", "2015", "1", "1", "1", "2", "0", "", "", "2", "2", "2", "24.0", "24.0", "", "", "87.9", "80.9", "", "47.0", "", "2", "", "", "106", "1", "2", "166", "", "2", "2", "0", "150", "0", "45", "2", "60", "", "0", "", "", "", "", "", "", "", "", "", "0", "0", "", "0005", "", "", "", "", "", "", "", "", "87.2", "96.9", "", "", "", "", "95.0"]} +{"pcdb_id": 15067, "brand_name": "Vokera", "model_name": "Compact", "model_qualifier": "35 HE", "winter_efficiency_pct": 85.2, "summer_efficiency_pct": 76.6, "comparative_hot_water_efficiency_pct": 53.9, "output_kw_max": 33.8, "final_year_of_manufacture": 2013, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015067", "000011", "0", "2014/May/09 12:49", "Vokera", "Vokera", "Compact", "35 HE", "", "2005", "2013", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "33.8", "33.8", "", "", "85.2", "76.6", "", "53.9", "", "2", "", "", "104", "1", "2", "153", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.6", "89.9", "", "", "", "", "89.5"]} +{"pcdb_id": 15068, "brand_name": "Vokera", "model_name": "Unica", "model_qualifier": "28 HE", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 86.8, "comparative_hot_water_efficiency_pct": 69.6, "output_kw_max": 19.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0015, "loss_factor_f1_kwh_per_day": 1.44242, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015068", "000011", "0", "2012/Nov/06 13:20", "Vokera", "Vokera", "Unica", "28 HE", "4709483", "2006", "current", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "19.6", "19.6", "", "", "88.2", "86.8", "", "69.6", "", "2", "", "", "104", "1", "2", "150", "", "0", "", "", "0", "0", "", "", "", "", "1", "7.57", "159.0", "0.0015", "1.44242", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.5", "97.0", "", "", "", "", "95.4"]} +{"pcdb_id": 15069, "brand_name": "Vokera", "model_name": "Unica", "model_qualifier": "32 HE", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 55.9, "output_kw_max": 24.45, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015069", "000011", "0", "2011/Mar/24 12:37", "Vokera", "Vokera", "Unica", "32 HE", "4709485", "2006", "current", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "24.45", "24.45", "", "", "88.2", "79.6", "", "55.9", "", "2", "", "", "104", "1", "2", "150", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.1", "97.1", "", "", "", "", "95.4"]} +{"pcdb_id": 15070, "brand_name": "Vokera", "model_name": "Unica", "model_qualifier": "HE", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 55.9, "output_kw_max": 29.31, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015070", "000011", "0", "2007/May/24 10:25", "Vokera", "Vokera", "Unica", "HE", "", "2006", "current", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "29.31", "29.31", "", "", "88.1", "79.5", "", "55.9", "", "2", "", "", "104", "1", "2", "150", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "97.1", "", "", "", "", "95.4"]} +{"pcdb_id": 15072, "brand_name": "Vokera", "model_name": "Mynute", "model_qualifier": "12 HE", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 11.84, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015072", "000011", "0", "2012/Mar/27 10:12", "Vokera", "Vokera", "Mynute", "12 HE", "4109454", "2006", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "11.84", "11.84", "", "", "88.1", "79.1", "", "57.8", "", "2", "", "", "102", "1", "2", "150", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.9", "96.6", "", "", "", "", "95.1"]} +{"pcdb_id": 15073, "brand_name": "Vokera", "model_name": "Mynute", "model_qualifier": "15 HE", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 14.81, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015073", "000011", "0", "2012/Mar/30 09:39", "Vokera", "Vokera", "Mynute", "15 HE", "4109456", "2006", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "14.81", "14.81", "", "", "88.1", "79.1", "", "57.8", "", "2", "", "", "102", "1", "2", "150", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.9", "96.6", "", "", "", "", "95.1"]} +{"pcdb_id": 15074, "brand_name": "Vokera", "model_name": "Mynute", "model_qualifier": "20 HE", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 19.68, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015074", "000011", "0", "2012/Mar/27 10:12", "Vokera", "Vokera", "Mynute", "20 HE", "4109458", "2006", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "19.68", "19.68", "", "", "88.1", "79.1", "", "57.8", "", "2", "", "", "102", "1", "2", "150", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.7", "96.9", "", "", "", "", "95.3"]} +{"pcdb_id": 15075, "brand_name": "Vokera", "model_name": "Mynute", "model_qualifier": "25 HE", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 24.53, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015075", "000011", "0", "2012/Mar/27 10:12", "Vokera", "Vokera", "Mynute", "25 HE", "4109460", "2006", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "24.53", "24.53", "", "", "88.1", "79.1", "", "57.8", "", "2", "", "", "102", "1", "2", "150", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.4", "96.9", "", "", "", "", "95.3"]} +{"pcdb_id": 15076, "brand_name": "Vokera", "model_name": "Mynute", "model_qualifier": "30 HE", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 29.31, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015076", "000011", "0", "2012/Mar/27 10:12", "Vokera", "Vokera", "Mynute", "30 HE", "4109462", "2006", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "29.31", "29.31", "", "", "88.1", "79.1", "", "57.8", "", "2", "", "", "102", "1", "2", "150", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "97.1", "", "", "", "", "95.4"]} +{"pcdb_id": 15077, "brand_name": "Vokera", "model_name": "Mynute", "model_qualifier": "HE", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 33.67, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015077", "000011", "0", "2012/Mar/27 10:12", "Vokera", "Vokera", "Mynute", "HE", "", "2006", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "33.67", "33.67", "", "", "88.1", "79.1", "", "57.8", "", "2", "", "", "102", "1", "2", "165", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.7", "97.1", "", "", "", "", "95.3"]} +{"pcdb_id": 15078, "brand_name": "Remeha", "model_name": "Avanta", "model_qualifier": "18V", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 17.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015078", "000005", "0", "2012/Apr/11 14:49", "Broag Remeha", "Remeha", "Avanta", "18V", "", "2006", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "17.6", "17.6", "", "", "88.5", "79.5", "", "58.1", "", "2", "", "", "102", "1", "2", "50", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.6", "97.9", "", "", "", "", "96.2"]} +{"pcdb_id": 15080, "brand_name": "Trianco", "model_name": "Contractor Combi 110 External", "model_qualifier": "", "winter_efficiency_pct": 84.7, "summer_efficiency_pct": 76.6, "comparative_hot_water_efficiency_pct": 47.2, "output_kw_max": 31.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015080", "000062", "0", "2024/Jan/31 10:17", "Trianco Heating Products", "Trianco", "Contractor Combi 110 External", "", "", "2006", "current", "4", "1", "2", "2", "0", "", "", "1", "3", "2", "31.6", "31.6", "", "", "84.7", "76.6", "", "47.2", "", "2", "", "", "203", "1", "1", "148", "0", "2", "1", "0", "31", "0", "25", "1", "80", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.6", "87.0", "", "", "", "", "87.2"]} +{"pcdb_id": 15081, "brand_name": "Trianco", "model_name": "Iona Combi 110 External", "model_qualifier": "", "winter_efficiency_pct": 84.7, "summer_efficiency_pct": 76.6, "comparative_hot_water_efficiency_pct": 47.2, "output_kw_max": 31.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015081", "000062", "0", "2024/Jan/31 10:17", "Trianco Heating Products", "Trianco", "Iona Combi 110 External", "", "", "2006", "current", "4", "1", "2", "2", "0", "", "", "1", "3", "2", "31.6", "31.6", "", "", "84.7", "76.6", "", "47.2", "", "2", "", "", "203", "1", "1", "148", "0", "2", "1", "0", "31", "0", "25", "1", "80", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.6", "87.0", "", "", "", "", "87.2"]} +{"pcdb_id": 15082, "brand_name": "Trianco", "model_name": "Iona Combi 110", "model_qualifier": "", "winter_efficiency_pct": 84.7, "summer_efficiency_pct": 76.6, "comparative_hot_water_efficiency_pct": 47.2, "output_kw_max": 31.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015082", "000062", "0", "2024/Jan/31 10:17", "Trianco Heating Products", "Trianco", "Iona Combi 110", "", "", "2006", "current", "4", "1", "1", "2", "0", "", "", "1", "3", "2", "31.6", "31.6", "", "", "84.7", "76.6", "", "47.2", "", "2", "", "", "203", "1", "1", "148", "0", "2", "1", "0", "31", "0", "25", "1", "80", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.6", "87.0", "", "", "", "", "87.2"]} +{"pcdb_id": 15083, "brand_name": "Trianco", "model_name": "Contractor Combi 110", "model_qualifier": "", "winter_efficiency_pct": 84.7, "summer_efficiency_pct": 76.6, "comparative_hot_water_efficiency_pct": 47.2, "output_kw_max": 31.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015083", "000062", "0", "2024/Jan/31 10:17", "Trianco Heating Products", "Trianco", "Contractor Combi 110", "", "2307", "2006", "current", "4", "1", "1", "2", "0", "", "", "1", "3", "2", "31.6", "31.6", "", "", "84.7", "76.6", "", "47.2", "", "2", "", "", "203", "1", "1", "148", "0", "2", "1", "0", "31", "0", "25", "1", "80", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.6", "87.0", "", "", "", "", "87.2"]} +{"pcdb_id": 15084, "brand_name": "Gledhill", "model_name": "GB35C", "model_qualifier": "AGB5035", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 56.3, "output_kw_max": 28.9, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015084", "000072", "0", "2006/Sep/28 13:36", "Gledhill Water Storage", "Gledhill", "GB35C", "AGB5035", "GC No 47-317-01", "2006", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28.9", "28.9", "", "", "88.7", "80.1", "", "56.3", "", "2", "", "", "104", "1", "2", "155", "15", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.5", "97.8", "", "", "", "", "96.3"]} +{"pcdb_id": 15085, "brand_name": "Ideal", "model_name": "Mini", "model_qualifier": "HE C32", "winter_efficiency_pct": 85.5, "summer_efficiency_pct": 76.9, "comparative_hot_water_efficiency_pct": 54.1, "output_kw_max": 32.2, "final_year_of_manufacture": 2011, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015085", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "Mini", "HE C32", "47-348-41", "2006", "2011", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "32.2", "32.2", "", "", "85.5", "76.9", "", "54.1", "", "2", "", "", "104", "1", "2", "150", "7", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.1", "90.7", "", "", "", "", "90.0"]} +{"pcdb_id": 15087, "brand_name": "Baxi", "model_name": "Solo", "model_qualifier": "18 HE", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 17.81, "final_year_of_manufacture": 2010, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015087", "000005", "0", "2020/Dec/07 12:12", "Baxi Heating UK", "Baxi", "Solo", "18 HE", "GC No. 41-075-51", "2006", "2010", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "17.81", "17.81", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "96.8", "", "", "", "", "95.2"]} +{"pcdb_id": 15088, "brand_name": "Baxi", "model_name": "Solo", "model_qualifier": "12 HE", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 11.82, "final_year_of_manufacture": 2010, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015088", "000005", "0", "2020/Dec/07 12:13", "Baxi Heating UK", "Baxi", "Solo", "12 HE", "Gc No. 41-075-50", "2006", "2010", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "11.82", "11.82", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "80", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.6", "96.5", "", "", "", "", "95.0"]} +{"pcdb_id": 15090, "brand_name": "Worcester", "model_name": "Greenstar Heatslave", "model_qualifier": "25/32", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 81.9, "comparative_hot_water_efficiency_pct": 41.6, "output_kw_max": 32.0, "final_year_of_manufacture": 2013, "subsidiary_type": 0, "store_type": 1, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015090", "000035", "0", "2024/Jan/31 10:17", "Worcester Bosch Group", "Worcester", "Greenstar Heatslave", "25/32", "", "2006", "2013", "4", "1", "1", "2", "0", "", "", "2", "3", "2", "25", "32", "", "", "88.0", "81.9", "", "41.6", "", "2", "", "", "203", "1", "1", "123", "0", "1", "1", "0", "69", "0", "25", "3", "82", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.8", "94.4", "", "", "", "", "93.9"]} +{"pcdb_id": 15091, "brand_name": "Worcester", "model_name": "Greenstar Heatslave", "model_qualifier": "12/18", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 82.1, "comparative_hot_water_efficiency_pct": 41.6, "output_kw_max": 18.0, "final_year_of_manufacture": 2013, "subsidiary_type": 0, "store_type": 1, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015091", "000035", "0", "2024/Jan/31 10:17", "Worcester Bosch Group", "Worcester", "Greenstar Heatslave", "12/18", "", "2006", "2013", "4", "1", "1", "2", "0", "", "", "2", "3", "2", "12", "18", "", "", "88.2", "82.1", "", "41.6", "", "2", "", "", "203", "1", "1", "135", "0", "1", "1", "0", "69", "0", "25", "3", "82", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.6", "95.3", "", "", "", "", "94.4"]} +{"pcdb_id": 15093, "brand_name": "Grant", "model_name": "Vortex Utility 15-21", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 80.6, "comparative_hot_water_efficiency_pct": 58.9, "output_kw_max": 21.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015093", "000048", "0", "2012/Mar/27 10:12", "Grant Engineering (UK)", "Grant", "Vortex Utility 15-21", "", "", "2006", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "15", "21", "", "", "88.4", "80.6", "", "58.9", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "88.9", "97.1", "", "", "", "", "95.5"]} +{"pcdb_id": 15094, "brand_name": "Grant", "model_name": "Vortex Outdoor Module 15-21", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 80.6, "comparative_hot_water_efficiency_pct": 58.9, "output_kw_max": 21.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015094", "000048", "0", "2012/Mar/27 10:12", "Grant Engineering (UK)", "Grant", "Vortex Outdoor Module 15-21", "", "", "2006", "current", "4", "1", "2", "1", "0", "", "", "2", "3", "2", "15", "21", "", "", "88.4", "80.6", "", "58.9", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "88.9", "97.1", "", "", "", "", "95.5"]} +{"pcdb_id": 15095, "brand_name": "Grant", "model_name": "Vortex Outdoor", "model_qualifier": "Combi 21", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 82.3, "comparative_hot_water_efficiency_pct": 45.0, "output_kw_max": 21.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 1, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015095", "000048", "0", "2024/Jan/31 10:17", "Grant Engineering (UK)", "Grant", "Vortex Outdoor", "Combi 21", "", "2006", "current", "4", "1", "2", "2", "0", "", "", "2", "3", "2", "21", "21", "", "", "88.4", "82.3", "", "45.0", "", "2", "", "", "203", "1", "1", "", "", "1", "", "", "40", "0", "25", "3", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "88.9", "97.1", "", "", "", "", "95.5"]} +{"pcdb_id": 15096, "brand_name": "Grant", "model_name": "Vortex Condensing", "model_qualifier": "Combi 21", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 82.3, "comparative_hot_water_efficiency_pct": 45.0, "output_kw_max": 21.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 1, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015096", "000048", "0", "2024/Jan/31 10:17", "Grant Engineering (UK)", "Grant", "Vortex Condensing", "Combi 21", "", "2006", "current", "4", "1", "1", "2", "0", "", "", "2", "3", "2", "21", "21", "", "", "88.4", "82.3", "", "45.0", "", "2", "", "", "203", "1", "1", "", "", "1", "", "", "40", "0", "25", "3", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "88.9", "97.1", "", "", "", "", "95.5"]} +{"pcdb_id": 15097, "brand_name": "Ideal", "model_name": "mini", "model_qualifier": "HE C32", "winter_efficiency_pct": 87.4, "summer_efficiency_pct": 78.8, "comparative_hot_water_efficiency_pct": 55.4, "output_kw_max": 32.2, "final_year_of_manufacture": 2011, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015097", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "mini", "HE C32", "47-348-41", "2006", "2011", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "32.2", "32.2", "", "", "87.4", "78.8", "", "55.4", "", "2", "0", "", "104", "1", "2", "150", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.1", "92.7", "", "", "", "", "92.0"]} +{"pcdb_id": 15098, "brand_name": "Potterton", "model_name": "Promax", "model_qualifier": "12 HE Plus", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 11.82, "final_year_of_manufacture": 2006, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015098", "000005", "0", "2012/Mar/27 10:12", "Baxi Heating UK", "Potterton", "Promax", "12 HE Plus", "GC No 41-591-79", "2006", "2006", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "11.82", "11.82", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "80", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.6", "96.5", "", "", "", "", "95.0"]} +{"pcdb_id": 15099, "brand_name": "Potterton", "model_name": "Promax", "model_qualifier": "18 HE Plus", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 17.81, "final_year_of_manufacture": 2006, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015099", "000005", "0", "2012/Mar/27 10:12", "Baxi Heating UK", "Potterton", "Promax", "18 HE Plus", "GC No. 41-591-80", "2006", "2006", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "17.81", "17.81", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "96.8", "", "", "", "", "95.2"]} +{"pcdb_id": 15100, "brand_name": "Vaillant", "model_name": "Ecotec plus 415", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 15.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015100", "000031", "0", "2012/Mar/27 10:12", "Vaillant", "Vaillant", "Ecotec plus 415", "", "GC No. 41.044.53", "2006", "2015", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "15", "15", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "60", "8", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0045", "", "", "", "", "", "", "", "", "88.6", "96.5", "", "", "", "", "95.0"]} +{"pcdb_id": 15101, "brand_name": "Vaillant", "model_name": "Ecotec plus 418", "model_qualifier": "", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 18.6, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015101", "000031", "0", "2012/Mar/27 10:12", "Vaillant", "Vaillant", "Ecotec plus 418", "", "GC No. 41.044.54", "2006", "2015", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18.6", "18.6", "", "", "88.2", "79.2", "", "57.8", "", "2", "", "", "102", "1", "2", "60", "8", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0045", "", "", "", "", "", "", "", "", "88.6", "96.9", "", "", "", "", "95.4"]} +{"pcdb_id": 15102, "brand_name": "Vaillant", "model_name": "Ecotec plus 418", "model_qualifier": "", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 18.6, "final_year_of_manufacture": 2019, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015102", "000031", "0", "2019/Mar/04 10:05", "Vaillant", "Vaillant", "Ecotec plus 418", "", "", "2006", "2019", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "18.6", "18.6", "", "", "89.2", "80.2", "", "58.6", "", "2", "1", "", "102", "1", "2", "60", "8", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.5", "99.1", "", "", "", "", "97.5"]} +{"pcdb_id": 15103, "brand_name": "Vaillant", "model_name": "Ecotec plus 415", "model_qualifier": "", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 15.0, "final_year_of_manufacture": 2019, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015103", "000031", "0", "2019/Mar/04 10:05", "Vaillant", "Vaillant", "Ecotec plus 415", "", "", "2006", "2019", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "15", "15", "", "", "89.0", "80.0", "", "58.4", "", "2", "1", "", "102", "1", "2", "60", "8", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.5", "98.6", "", "", "", "", "97.1"]} +{"pcdb_id": 15104, "brand_name": "Vaillant", "model_name": "Ecotec plus 438", "model_qualifier": "", "winter_efficiency_pct": 89.5, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 58.8, "output_kw_max": 38.0, "final_year_of_manufacture": 2019, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015104", "000031", "0", "2019/Mar/04 10:08", "Vaillant", "Vaillant", "Ecotec plus 438", "", "", "2006", "2019", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "38", "38", "", "", "89.5", "80.5", "", "58.8", "", "2", "1", "", "102", "1", "2", "60", "8", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "91.3", "99.7", "", "", "", "", "98.1"]} +{"pcdb_id": 15105, "brand_name": "Vaillant", "model_name": "Ecotec plus 428", "model_qualifier": "", "winter_efficiency_pct": 90.0, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 59.2, "output_kw_max": 28.2, "final_year_of_manufacture": 2019, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015105", "000031", "0", "2019/Mar/04 10:07", "Vaillant", "Vaillant", "Ecotec plus 428", "", "", "2006", "2019", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "28.2", "28.2", "", "", "90.0", "81.0", "", "59.2", "", "2", "0", "", "102", "1", "2", "60", "8", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.8", "99.0", "", "", "", "", "97.3"]} +{"pcdb_id": 15106, "brand_name": "Vaillant", "model_name": "Ecotec plus 428", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 28.2, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015106", "000031", "0", "2012/Mar/27 10:12", "Vaillant", "Vaillant", "Ecotec plus 428", "", "GC No. 41.044.55", "2006", "2015", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "28.2", "28.2", "", "", "88.1", "79.1", "", "57.8", "", "2", "", "", "102", "1", "2", "60", "8", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0045", "", "", "", "", "", "", "", "", "88.7", "96.9", "", "", "", "", "95.3"]} +{"pcdb_id": 15107, "brand_name": "Vaillant", "model_name": "Ecotec plus 438", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 38.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015107", "000031", "0", "2015/Sep/21 14:23", "Vaillant", "Vaillant", "Ecotec plus 438", "", "GC No. 41.044.57", "2006", "2015", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "38", "38", "", "", "88.5", "79.5", "", "58.1", "", "2", "", "", "102", "1", "2", "60", "8", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0045", "", "", "", "", "", "", "", "", "89.3", "97.5", "", "", "", "", "95.9"]} +{"pcdb_id": 15109, "brand_name": "Mistral", "model_name": "KUT 2 70/90", "model_qualifier": "", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 26.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015109", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "KUT 2 70/90", "", "", "2006", "current", "4", "1", "1", "1", "0", "", "", "1", "3", "2", "20.5", "26.4", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.3", "87.3", "", "", "", "", "87.1"]} +{"pcdb_id": 15110, "brand_name": "Mistral", "model_name": "KUT 50/90 Contract", "model_qualifier": "", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 26.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015110", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "KUT 50/90 Contract", "", "", "2006", "current", "4", "1", "1", "1", "0", "", "", "1", "3", "2", "14.6", "26.4", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.3", "87.3", "", "", "", "", "87.1"]} +{"pcdb_id": 15111, "brand_name": "Mistral", "model_name": "KUT 1 50/70", "model_qualifier": "", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 20.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015111", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "KUT 1 50/70", "", "", "2006", "current", "4", "1", "1", "1", "0", "", "", "1", "3", "2", "14.6", "20.5", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.3", "87.3", "", "", "", "", "87.1"]} +{"pcdb_id": 15112, "brand_name": "Mistral", "model_name": "SS 50/90 Contract", "model_qualifier": "", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 26.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015112", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "SS 50/90 Contract", "", "", "2006", "current", "4", "1", "1", "1", "0", "", "", "1", "3", "2", "14.6", "26.4", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.3", "87.3", "", "", "", "", "87.1"]} +{"pcdb_id": 15113, "brand_name": "Mistral", "model_name": "S2 70/90", "model_qualifier": "", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 26.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015113", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "S2 70/90", "", "", "2006", "current", "4", "1", "1", "1", "0", "", "", "1", "3", "2", "20.5", "26.4", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.3", "87.3", "", "", "", "", "87.1"]} +{"pcdb_id": 15114, "brand_name": "Mistral", "model_name": "S1 50/70", "model_qualifier": "", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 20.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015114", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "S1 50/70", "", "", "2006", "current", "4", "1", "1", "1", "0", "", "", "1", "3", "2", "14.6", "20.5", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.3", "87.3", "", "", "", "", "87.1"]} +{"pcdb_id": 15115, "brand_name": "Mistral", "model_name": "C 50/90 Standard Contract", "model_qualifier": "", "winter_efficiency_pct": 84.8, "summer_efficiency_pct": 76.7, "comparative_hot_water_efficiency_pct": 46.9, "output_kw_max": 26.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015115", "000056", "0", "2024/Jan/31 10:17", "Mistral Boilers", "Mistral", "C 50/90 Standard Contract", "", "", "2006", "current", "4", "1", "1", "2", "0", "", "", "1", "3", "2", "14.6", "26.4", "", "", "84.8", "76.7", "", "46.9", "", "2", "", "", "203", "1", "1", "", "", "2", "", "0", "40", "0", "25", "1", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.3", "87.1", "", "", "", "", "87.0"]} +{"pcdb_id": 15116, "brand_name": "Mistral", "model_name": "C1 50/70 Standard", "model_qualifier": "", "winter_efficiency_pct": 84.8, "summer_efficiency_pct": 76.7, "comparative_hot_water_efficiency_pct": 46.9, "output_kw_max": 20.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015116", "000056", "0", "2024/Jan/31 10:17", "Mistral Boilers", "Mistral", "C1 50/70 Standard", "", "", "2006", "current", "4", "1", "1", "2", "0", "", "", "1", "3", "2", "14.6", "20.5", "", "", "84.8", "76.7", "", "46.9", "", "2", "", "", "203", "1", "1", "", "", "2", "", "0", "40", "0", "25", "1", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.3", "87.3", "", "", "", "", "87.1"]} +{"pcdb_id": 15117, "brand_name": "Mistral", "model_name": "C2 70/90 Standard", "model_qualifier": "", "winter_efficiency_pct": 84.8, "summer_efficiency_pct": 76.7, "comparative_hot_water_efficiency_pct": 46.9, "output_kw_max": 26.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015117", "000056", "0", "2024/Jan/31 10:17", "Mistral Boilers", "Mistral", "C2 70/90 Standard", "", "", "2006", "current", "4", "1", "1", "2", "0", "", "", "1", "3", "2", "20.5", "26.4", "", "", "84.8", "76.7", "", "46.9", "", "2", "", "", "203", "1", "1", "", "", "2", "", "0", "40", "0", "25", "1", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.3", "87.3", "", "", "", "", "87.1"]} +{"pcdb_id": 15118, "brand_name": "Mistral", "model_name": "BH 50/90 Contract", "model_qualifier": "", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 26.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015118", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "BH 50/90 Contract", "", "", "2006", "current", "4", "1", "1", "1", "0", "", "", "1", "3", "2", "14.6", "26.4", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.3", "87.3", "", "", "", "", "87.1"]} +{"pcdb_id": 15119, "brand_name": "Mistral", "model_name": "BH 2 70/90", "model_qualifier": "", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 26.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015119", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "BH 2 70/90", "", "", "2006", "current", "4", "1", "1", "1", "0", "", "", "1", "3", "2", "20.5", "26.4", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.3", "87.3", "", "", "", "", "87.1"]} +{"pcdb_id": 15120, "brand_name": "Mistral", "model_name": "BH 1 50/70", "model_qualifier": "", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 20.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015120", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "BH 1 50/70", "", "", "2006", "current", "4", "1", "1", "1", "0", "", "", "1", "3", "2", "14.6", "20.5", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.3", "87.3", "", "", "", "", "87.1"]} +{"pcdb_id": 15121, "brand_name": "Mistral", "model_name": "C2 70/90 Plus", "model_qualifier": "", "winter_efficiency_pct": 84.8, "summer_efficiency_pct": 76.7, "comparative_hot_water_efficiency_pct": 46.9, "output_kw_max": 26.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015121", "000056", "0", "2024/Jan/31 10:17", "Mistral Boilers", "Mistral", "C2 70/90 Plus", "", "", "2006", "current", "4", "1", "1", "2", "0", "", "", "1", "3", "2", "20.5", "26.4", "", "", "84.8", "76.7", "", "46.9", "", "2", "", "", "203", "1", "1", "230", "0", "2", "", "0", "40", "0", "25", "1", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.3", "87.3", "", "", "", "", "87.1"]} +{"pcdb_id": 15122, "brand_name": "Mistral", "model_name": "C1 50/70 Plus", "model_qualifier": "", "winter_efficiency_pct": 84.8, "summer_efficiency_pct": 76.7, "comparative_hot_water_efficiency_pct": 46.9, "output_kw_max": 20.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015122", "000056", "0", "2024/Jan/31 10:17", "Mistral Boilers", "Mistral", "C1 50/70 Plus", "", "", "2006", "current", "4", "1", "1", "2", "0", "", "", "1", "3", "2", "14.6", "20.5", "", "", "84.8", "76.7", "", "46.9", "", "2", "", "", "203", "1", "1", "230", "0", "2", "", "0", "40", "0", "25", "1", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.3", "87.3", "", "", "", "", "87.1"]} +{"pcdb_id": 15123, "brand_name": "Mistral", "model_name": "C 50/90 Plus", "model_qualifier": "", "winter_efficiency_pct": 84.8, "summer_efficiency_pct": 76.7, "comparative_hot_water_efficiency_pct": 46.9, "output_kw_max": 26.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015123", "000056", "0", "2024/Jan/31 10:17", "Mistral Boilers", "Mistral", "C 50/90 Plus", "", "", "2006", "current", "4", "1", "1", "2", "0", "", "", "1", "3", "2", "14.6", "26.4", "", "", "84.8", "76.7", "", "46.9", "", "2", "", "", "203", "1", "1", "230", "0", "2", "", "0", "40", "0", "25", "1", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.3", "87.3", "", "", "", "", "87.1"]} +{"pcdb_id": 15124, "brand_name": "Mistral", "model_name": "OD 1 50/70", "model_qualifier": "", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 20.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015124", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "OD 1 50/70", "", "", "2006", "current", "4", "1", "2", "1", "0", "", "", "1", "3", "2", "14.6", "20.5", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.3", "87.3", "", "", "", "", "87.1"]} +{"pcdb_id": 15125, "brand_name": "Mistral", "model_name": "OD 50/90", "model_qualifier": "", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 26.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015125", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "OD 50/90", "", "", "2006", "current", "4", "1", "2", "1", "0", "", "", "1", "3", "2", "14.6", "26.4", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.3", "87.3", "", "", "", "", "87.1"]} +{"pcdb_id": 15126, "brand_name": "Mistral", "model_name": "OD 2 70/90", "model_qualifier": "", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 26.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015126", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "OD 2 70/90", "", "", "2006", "current", "4", "1", "2", "1", "0", "", "", "1", "3", "2", "20.5", "26.4", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "230", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.3", "87.3", "", "", "", "", "87.1"]} +{"pcdb_id": 15127, "brand_name": "Mistral", "model_name": "OD1 SS 50/70", "model_qualifier": "", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 20.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015127", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "OD1 SS 50/70", "", "", "2006", "current", "4", "1", "2", "1", "0", "", "", "1", "3", "2", "14.6", "20.5", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.3", "87.3", "", "", "", "", "87.1"]} +{"pcdb_id": 15128, "brand_name": "Mistral", "model_name": "OD2 SS 70/90", "model_qualifier": "", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 26.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015128", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "OD2 SS 70/90", "", "", "2006", "current", "4", "1", "2", "1", "0", "", "", "1", "3", "2", "20.5", "26.4", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.3", "87.3", "", "", "", "", "87.1"]} +{"pcdb_id": 15129, "brand_name": "Mistral", "model_name": "OD SS 50/90 Contract", "model_qualifier": "", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 26.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015129", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "OD SS 50/90 Contract", "", "", "2006", "current", "4", "1", "2", "1", "0", "", "", "1", "3", "2", "14.6", "26.4", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.3", "87.3", "", "", "", "", "87.1"]} +{"pcdb_id": 15130, "brand_name": "Mistral", "model_name": "ODC1 50/70 Standard", "model_qualifier": "", "winter_efficiency_pct": 84.8, "summer_efficiency_pct": 76.7, "comparative_hot_water_efficiency_pct": 46.9, "output_kw_max": 20.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015130", "000056", "0", "2024/Jan/31 10:17", "Mistral Boilers", "Mistral", "ODC1 50/70 Standard", "", "", "2006", "current", "4", "1", "2", "2", "0", "", "", "1", "3", "2", "14.6", "20.5", "", "", "84.8", "76.7", "", "46.9", "", "2", "", "", "203", "1", "1", "230", "0", "2", "", "0", "40", "0", "25", "1", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.3", "87.3", "", "", "", "", "87.1"]} +{"pcdb_id": 15131, "brand_name": "Mistral", "model_name": "ODC 50/90 Standard Contract", "model_qualifier": "", "winter_efficiency_pct": 84.8, "summer_efficiency_pct": 76.7, "comparative_hot_water_efficiency_pct": 46.9, "output_kw_max": 26.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015131", "000056", "0", "2024/Jan/31 10:17", "Mistral Boilers", "Mistral", "ODC 50/90 Standard Contract", "", "", "2006", "current", "4", "1", "2", "2", "0", "", "", "1", "3", "2", "14.6", "26.4", "", "", "84.8", "76.7", "", "46.9", "", "2", "", "", "203", "1", "1", "230", "0", "2", "", "0", "40", "0", "25", "1", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.3", "87.3", "", "", "", "", "87.1"]} +{"pcdb_id": 15132, "brand_name": "Mistral", "model_name": "ODC2 70/90 Standard", "model_qualifier": "", "winter_efficiency_pct": 84.8, "summer_efficiency_pct": 76.7, "comparative_hot_water_efficiency_pct": 46.9, "output_kw_max": 26.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015132", "000056", "0", "2024/Jan/31 10:17", "Mistral Boilers", "Mistral", "ODC2 70/90 Standard", "", "", "2006", "current", "4", "1", "2", "2", "0", "", "", "1", "3", "2", "20.5", "26.4", "", "", "84.8", "76.7", "", "46.9", "", "2", "", "", "203", "1", "1", "", "", "2", "", "0", "40", "0", "25", "1", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.3", "87.3", "", "", "", "", "87.1"]} +{"pcdb_id": 15133, "brand_name": "Mistral", "model_name": "ODC 50/90 Plus Contract", "model_qualifier": "", "winter_efficiency_pct": 84.8, "summer_efficiency_pct": 76.7, "comparative_hot_water_efficiency_pct": 46.9, "output_kw_max": 26.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015133", "000056", "0", "2024/Jan/31 10:17", "Mistral Boilers", "Mistral", "ODC 50/90 Plus Contract", "", "", "2006", "current", "4", "1", "2", "2", "0", "", "", "1", "3", "2", "14.6", "26.4", "", "", "84.8", "76.7", "", "46.9", "", "2", "", "", "203", "1", "1", "230", "0", "2", "", "0", "40", "0", "25", "1", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.3", "87.3", "", "", "", "", "87.1"]} +{"pcdb_id": 15134, "brand_name": "Mistral", "model_name": "ODC2 70/90 Plus", "model_qualifier": "", "winter_efficiency_pct": 84.8, "summer_efficiency_pct": 76.7, "comparative_hot_water_efficiency_pct": 46.9, "output_kw_max": 26.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015134", "000056", "0", "2024/Jan/31 10:17", "Mistral Boilers", "Mistral", "ODC2 70/90 Plus", "", "", "2006", "current", "4", "1", "2", "2", "0", "", "", "1", "3", "2", "20.5", "26.4", "", "", "84.8", "76.7", "", "46.9", "", "2", "", "", "203", "1", "1", "230", "0", "2", "", "0", "40", "0", "25", "1", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.3", "87.3", "", "", "", "", "87.1"]} +{"pcdb_id": 15135, "brand_name": "Mistral", "model_name": "OD C1 50/70 Plus", "model_qualifier": "", "winter_efficiency_pct": 84.8, "summer_efficiency_pct": 76.7, "comparative_hot_water_efficiency_pct": 46.9, "output_kw_max": 20.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015135", "000056", "0", "2024/Jan/31 10:17", "Mistral Boilers", "Mistral", "OD C1 50/70 Plus", "", "", "2006", "current", "4", "1", "2", "2", "0", "", "", "1", "3", "2", "14.6", "20.5", "", "", "84.8", "76.7", "", "46.9", "", "2", "", "", "203", "1", "1", "230", "0", "2", "", "0", "40", "0", "25", "1", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.3", "87.3", "", "", "", "", "87.1"]} +{"pcdb_id": 15136, "brand_name": "Mistral", "model_name": "ODC 90/150 Plus", "model_qualifier": "", "winter_efficiency_pct": 84.7, "summer_efficiency_pct": 76.6, "comparative_hot_water_efficiency_pct": 46.9, "output_kw_max": 44.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015136", "000056", "0", "2024/Jan/31 10:17", "Mistral Boilers", "Mistral", "ODC 90/150 Plus", "", "", "2006", "current", "4", "1", "2", "2", "0", "", "", "1", "3", "2", "26.4", "44", "", "", "84.7", "76.6", "", "46.9", "", "2", "", "", "203", "1", "1", "230", "0", "2", "", "0", "40", "0", "25", "1", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.1", "88.4", "", "", "", "", "87.9"]} +{"pcdb_id": 15137, "brand_name": "Mistral", "model_name": "ODC 3 90/120 Plus", "model_qualifier": "", "winter_efficiency_pct": 84.7, "summer_efficiency_pct": 76.6, "comparative_hot_water_efficiency_pct": 46.1, "output_kw_max": 35.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015137", "000056", "0", "2024/Jan/31 10:17", "Mistral Boilers", "Mistral", "ODC 3 90/120 Plus", "", "", "2006", "current", "4", "1", "2", "2", "0", "", "", "1", "3", "2", "26.4", "35.2", "", "", "84.7", "76.6", "", "46.1", "", "2", "", "", "203", "1", "1", "230", "0", "2", "", "0", "60", "0", "25", "1", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.1", "88.4", "", "", "", "", "87.9"]} +{"pcdb_id": 15138, "brand_name": "Mistral", "model_name": "ODC4 120/150 Plus", "model_qualifier": "", "winter_efficiency_pct": 84.7, "summer_efficiency_pct": 76.6, "comparative_hot_water_efficiency_pct": 46.1, "output_kw_max": 44.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015138", "000056", "0", "2024/Jan/31 10:17", "Mistral Boilers", "Mistral", "ODC4 120/150 Plus", "", "", "2006", "current", "4", "1", "2", "2", "0", "", "", "1", "3", "2", "35.2", "44", "", "", "84.7", "76.6", "", "46.1", "", "2", "", "", "203", "1", "1", "230", "0", "2", "", "0", "60", "0", "25", "1", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.1", "88.4", "", "", "", "", "87.9"]} +{"pcdb_id": 15139, "brand_name": "Mistral", "model_name": "ODC 90/150 Standard", "model_qualifier": "", "winter_efficiency_pct": 84.7, "summer_efficiency_pct": 76.6, "comparative_hot_water_efficiency_pct": 46.1, "output_kw_max": 44.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015139", "000056", "0", "2024/Jan/31 10:17", "Mistral Boilers", "Mistral", "ODC 90/150 Standard", "", "", "2006", "current", "4", "1", "2", "2", "0", "", "", "1", "3", "2", "26.4", "44", "", "", "84.7", "76.6", "", "46.1", "", "2", "", "", "203", "1", "1", "230", "0", "2", "", "0", "60", "0", "25", "1", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.1", "88.4", "", "", "", "", "87.9"]} +{"pcdb_id": 15140, "brand_name": "Mistral", "model_name": "ODC4 120/150 Standard", "model_qualifier": "", "winter_efficiency_pct": 84.7, "summer_efficiency_pct": 76.6, "comparative_hot_water_efficiency_pct": 46.1, "output_kw_max": 44.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015140", "000056", "0", "2024/Jan/31 10:17", "Mistral Boilers", "Mistral", "ODC4 120/150 Standard", "", "", "2006", "current", "4", "1", "2", "2", "0", "", "", "1", "3", "2", "35.2", "44", "", "", "84.7", "76.6", "", "46.1", "", "2", "", "", "203", "1", "1", "230", "0", "2", "", "0", "60", "0", "25", "1", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.1", "88.4", "", "", "", "", "87.9"]} +{"pcdb_id": 15141, "brand_name": "Mistral", "model_name": "ODC3 90/120 Standard", "model_qualifier": "", "winter_efficiency_pct": 84.7, "summer_efficiency_pct": 76.6, "comparative_hot_water_efficiency_pct": 46.1, "output_kw_max": 35.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015141", "000056", "0", "2024/Jan/31 10:17", "Mistral Boilers", "Mistral", "ODC3 90/120 Standard", "", "", "2006", "current", "4", "1", "2", "2", "0", "", "", "1", "3", "2", "26.4", "35.2", "", "", "84.7", "76.6", "", "46.1", "", "2", "", "", "203", "1", "1", "230", "0", "2", "", "0", "60", "0", "25", "1", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "0", "", "0002", "", "", "", "", "", "", "", "", "86.1", "88.4", "", "", "", "", "87.9"]} +{"pcdb_id": 15142, "brand_name": "Mistral", "model_name": "OD3 90/120", "model_qualifier": "", "winter_efficiency_pct": 86.6, "summer_efficiency_pct": 74.9, "comparative_hot_water_efficiency_pct": 54.7, "output_kw_max": 35.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015142", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "OD3 90/120", "", "", "2006", "current", "4", "1", "2", "1", "0", "", "", "1", "3", "2", "26.4", "35.2", "", "", "86.6", "74.9", "", "54.7", "", "2", "", "", "201", "1", "1", "230", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.1", "88.4", "", "", "", "", "87.9"]} +{"pcdb_id": 15143, "brand_name": "Mistral", "model_name": "OD4 120/150", "model_qualifier": "", "winter_efficiency_pct": 86.6, "summer_efficiency_pct": 74.9, "comparative_hot_water_efficiency_pct": 54.7, "output_kw_max": 44.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015143", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "OD4 120/150", "", "", "2006", "current", "4", "1", "2", "1", "0", "", "", "1", "3", "2", "35.2", "44", "", "", "86.6", "74.9", "", "54.7", "", "2", "", "", "201", "1", "1", "230", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.1", "88.4", "", "", "", "", "87.9"]} +{"pcdb_id": 15144, "brand_name": "Mistral", "model_name": "OD 90/150 Contract", "model_qualifier": "", "winter_efficiency_pct": 86.6, "summer_efficiency_pct": 74.9, "comparative_hot_water_efficiency_pct": 54.7, "output_kw_max": 44.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015144", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "OD 90/150 Contract", "", "", "2006", "current", "4", "1", "2", "1", "0", "", "", "1", "3", "2", "26.4", "44", "", "", "86.6", "74.9", "", "54.7", "", "2", "", "", "201", "1", "1", "230", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.1", "88.4", "", "", "", "", "87.9"]} +{"pcdb_id": 15145, "brand_name": "Mistral", "model_name": "OD4 SS 120/150", "model_qualifier": "", "winter_efficiency_pct": 86.6, "summer_efficiency_pct": 74.9, "comparative_hot_water_efficiency_pct": 54.7, "output_kw_max": 44.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015145", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "OD4 SS 120/150", "", "", "2006", "current", "4", "1", "2", "1", "0", "", "", "1", "3", "2", "35.2", "44", "", "", "86.6", "74.9", "", "54.7", "", "2", "", "", "201", "1", "1", "230", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.1", "88.4", "", "", "", "", "87.9"]} +{"pcdb_id": 15146, "brand_name": "Mistral", "model_name": "OD3 SS 90/120", "model_qualifier": "", "winter_efficiency_pct": 86.6, "summer_efficiency_pct": 74.9, "comparative_hot_water_efficiency_pct": 54.7, "output_kw_max": 35.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015146", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "OD3 SS 90/120", "", "", "2006", "current", "4", "1", "2", "1", "0", "", "", "1", "3", "2", "26.4", "35.2", "", "", "86.6", "74.9", "", "54.7", "", "2", "", "", "201", "1", "1", "230", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.1", "88.4", "", "", "", "", "87.9"]} +{"pcdb_id": 15147, "brand_name": "Mistral", "model_name": "OD SS 90/150 Contract", "model_qualifier": "", "winter_efficiency_pct": 86.6, "summer_efficiency_pct": 74.9, "comparative_hot_water_efficiency_pct": 54.7, "output_kw_max": 44.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015147", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "OD SS 90/150 Contract", "", "", "2006", "current", "4", "1", "2", "1", "0", "", "", "1", "3", "2", "26.4", "44", "", "", "86.6", "74.9", "", "54.7", "", "2", "", "", "201", "1", "1", "230", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.1", "88.4", "", "", "", "", "87.9"]} +{"pcdb_id": 15148, "brand_name": "Mistral", "model_name": "SS 90/150 Contract", "model_qualifier": "", "winter_efficiency_pct": 86.6, "summer_efficiency_pct": 74.9, "comparative_hot_water_efficiency_pct": 54.7, "output_kw_max": 44.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015148", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "SS 90/150 Contract", "", "", "2006", "current", "4", "1", "1", "1", "0", "", "", "1", "3", "2", "26.4", "44", "", "", "86.6", "74.9", "", "54.7", "", "2", "", "", "201", "1", "1", "230", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.1", "88.4", "", "", "", "", "87.9"]} +{"pcdb_id": 15149, "brand_name": "Mistral", "model_name": "S3 90/120", "model_qualifier": "", "winter_efficiency_pct": 86.6, "summer_efficiency_pct": 74.9, "comparative_hot_water_efficiency_pct": 54.7, "output_kw_max": 35.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015149", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "S3 90/120", "", "", "2006", "current", "4", "1", "1", "1", "0", "", "", "1", "3", "2", "26.4", "35.2", "", "", "86.6", "74.9", "", "54.7", "", "2", "", "", "201", "1", "1", "230", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.1", "88.4", "", "", "", "", "87.9"]} +{"pcdb_id": 15150, "brand_name": "Mistral", "model_name": "S4 120/150", "model_qualifier": "", "winter_efficiency_pct": 86.6, "summer_efficiency_pct": 74.9, "comparative_hot_water_efficiency_pct": 54.7, "output_kw_max": 44.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015150", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "S4 120/150", "", "", "2006", "current", "4", "1", "1", "1", "0", "", "", "1", "3", "2", "35.2", "44", "", "", "86.6", "74.9", "", "54.7", "", "2", "", "", "201", "1", "1", "230", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.1", "88.4", "", "", "", "", "87.9"]} +{"pcdb_id": 15151, "brand_name": "Mistral", "model_name": "KUT 90/150 Contract", "model_qualifier": "", "winter_efficiency_pct": 86.6, "summer_efficiency_pct": 74.9, "comparative_hot_water_efficiency_pct": 54.7, "output_kw_max": 44.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015151", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "KUT 90/150 Contract", "", "", "2006", "current", "4", "1", "1", "1", "0", "", "", "1", "3", "2", "35.2", "44", "", "", "86.6", "74.9", "", "54.7", "", "2", "", "", "201", "1", "1", "230", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.1", "88.4", "", "", "", "", "87.9"]} +{"pcdb_id": 15152, "brand_name": "Mistral", "model_name": "KUT3 90/120", "model_qualifier": "", "winter_efficiency_pct": 86.6, "summer_efficiency_pct": 74.9, "comparative_hot_water_efficiency_pct": 54.7, "output_kw_max": 35.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015152", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "KUT3 90/120", "", "", "2006", "current", "4", "1", "1", "1", "0", "", "", "1", "3", "2", "26.4", "35.2", "", "", "86.6", "74.9", "", "54.7", "", "2", "", "", "201", "1", "1", "230", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.1", "88.4", "", "", "", "", "87.9"]} +{"pcdb_id": 15153, "brand_name": "Mistral", "model_name": "KUT4 120/150", "model_qualifier": "", "winter_efficiency_pct": 86.6, "summer_efficiency_pct": 74.9, "comparative_hot_water_efficiency_pct": 54.7, "output_kw_max": 44.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015153", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "KUT4 120/150", "", "", "2006", "current", "4", "1", "1", "1", "0", "", "", "1", "3", "2", "35.2", "44", "", "", "86.6", "74.9", "", "54.7", "", "2", "", "", "201", "1", "1", "230", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.1", "88.4", "", "", "", "", "87.9"]} +{"pcdb_id": 15154, "brand_name": "Mistral", "model_name": "C3 90/120 Standard", "model_qualifier": "", "winter_efficiency_pct": 86.6, "summer_efficiency_pct": 74.9, "comparative_hot_water_efficiency_pct": 54.7, "output_kw_max": 35.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015154", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "C3 90/120 Standard", "", "", "2006", "current", "4", "1", "1", "1", "0", "", "", "1", "3", "2", "26.4", "35.2", "", "", "86.6", "74.9", "", "54.7", "", "2", "", "", "201", "1", "1", "230", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.1", "88.4", "", "", "", "", "87.9"]} +{"pcdb_id": 15155, "brand_name": "Mistral", "model_name": "C 90/150 Contract", "model_qualifier": "", "winter_efficiency_pct": 84.7, "summer_efficiency_pct": 76.6, "comparative_hot_water_efficiency_pct": 46.1, "output_kw_max": 44.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015155", "000056", "0", "2024/Jan/31 10:17", "Mistral Boilers", "Mistral", "C 90/150 Contract", "", "", "2006", "current", "4", "1", "1", "2", "0", "", "", "1", "3", "2", "26.4", "44", "", "", "84.7", "76.6", "", "46.1", "", "2", "", "", "203", "1", "1", "230", "0", "2", "", "0", "60", "0", "25", "1", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.1", "88.4", "", "", "", "", "87.9"]} +{"pcdb_id": 15156, "brand_name": "Mistral", "model_name": "C4 120/150 Standard", "model_qualifier": "", "winter_efficiency_pct": 84.7, "summer_efficiency_pct": 76.6, "comparative_hot_water_efficiency_pct": 46.1, "output_kw_max": 44.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015156", "000056", "0", "2024/Jan/31 10:17", "Mistral Boilers", "Mistral", "C4 120/150 Standard", "", "", "2006", "current", "4", "1", "1", "2", "0", "", "", "1", "3", "2", "35.2", "44", "", "", "84.7", "76.6", "", "46.1", "", "2", "", "", "203", "1", "1", "230", "0", "2", "", "0", "60", "0", "25", "1", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.1", "88.4", "", "", "", "", "87.9"]} +{"pcdb_id": 15157, "brand_name": "Mistral", "model_name": "C4 120/150 Plus", "model_qualifier": "", "winter_efficiency_pct": 84.7, "summer_efficiency_pct": 76.6, "comparative_hot_water_efficiency_pct": 46.1, "output_kw_max": 44.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015157", "000056", "0", "2024/Jan/31 10:17", "Mistral Boilers", "Mistral", "C4 120/150 Plus", "", "", "2006", "current", "4", "1", "1", "2", "0", "", "", "1", "3", "2", "35.2", "44", "", "", "84.7", "76.6", "", "46.1", "", "2", "", "", "203", "1", "1", "230", "0", "2", "", "0", "60", "0", "25", "1", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.1", "88.4", "", "", "", "", "87.9"]} +{"pcdb_id": 15158, "brand_name": "Mistral", "model_name": "C 90/150 Plus Contract", "model_qualifier": "", "winter_efficiency_pct": 84.7, "summer_efficiency_pct": 76.6, "comparative_hot_water_efficiency_pct": 46.1, "output_kw_max": 44.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015158", "000056", "0", "2024/Jan/31 10:17", "Mistral Boilers", "Mistral", "C 90/150 Plus Contract", "", "", "2006", "current", "4", "1", "1", "2", "0", "", "", "1", "3", "2", "26.4", "44", "", "", "84.7", "76.6", "", "46.1", "", "2", "", "", "203", "1", "1", "230", "0", "2", "", "0", "60", "0", "25", "1", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.1", "88.4", "", "", "", "", "87.9"]} +{"pcdb_id": 15159, "brand_name": "Mistral", "model_name": "C3 90/120 Plus", "model_qualifier": "", "winter_efficiency_pct": 84.7, "summer_efficiency_pct": 76.6, "comparative_hot_water_efficiency_pct": 46.1, "output_kw_max": 35.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015159", "000056", "0", "2024/Jan/31 10:17", "Mistral Boilers", "Mistral", "C3 90/120 Plus", "", "", "2006", "current", "4", "1", "1", "2", "0", "", "", "1", "3", "2", "26.4", "35.2", "", "", "84.7", "76.6", "", "46.1", "", "2", "", "", "203", "1", "1", "230", "0", "2", "", "0", "60", "0", "25", "1", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.1", "88.4", "", "", "", "", "87.9"]} +{"pcdb_id": 15160, "brand_name": "Mistral", "model_name": "BH3 90/120", "model_qualifier": "", "winter_efficiency_pct": 86.6, "summer_efficiency_pct": 74.9, "comparative_hot_water_efficiency_pct": 54.7, "output_kw_max": 35.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015160", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "BH3 90/120", "", "", "2006", "current", "4", "1", "1", "1", "0", "", "", "1", "3", "2", "26.4", "35.2", "", "", "86.6", "74.9", "", "54.7", "", "2", "", "", "201", "1", "1", "230", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.1", "88.4", "", "", "", "", "87.9"]} +{"pcdb_id": 15161, "brand_name": "Mistral", "model_name": "BH4 120/150", "model_qualifier": "", "winter_efficiency_pct": 86.6, "summer_efficiency_pct": 74.9, "comparative_hot_water_efficiency_pct": 54.7, "output_kw_max": 44.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015161", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "BH4 120/150", "", "", "2006", "current", "4", "1", "1", "1", "0", "", "", "1", "3", "2", "35.2", "44", "", "", "86.6", "74.9", "", "54.7", "", "2", "", "", "201", "1", "1", "230", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.1", "88.4", "", "", "", "", "87.9"]} +{"pcdb_id": 15162, "brand_name": "Mistral", "model_name": "BH 90/150 Contract", "model_qualifier": "", "winter_efficiency_pct": 86.6, "summer_efficiency_pct": 74.9, "comparative_hot_water_efficiency_pct": 54.7, "output_kw_max": 44.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015162", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "BH 90/150 Contract", "", "", "2006", "current", "4", "1", "1", "1", "0", "", "", "1", "3", "2", "26.4", "44", "", "", "86.6", "74.9", "", "54.7", "", "2", "", "", "201", "1", "1", "230", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.1", "88.4", "", "", "", "", "87.9"]} +{"pcdb_id": 15163, "brand_name": "Glow-worm", "model_name": "Betacom 24", "model_qualifier": "", "winter_efficiency_pct": 85.3, "summer_efficiency_pct": 76.7, "comparative_hot_water_efficiency_pct": 53.9, "output_kw_max": 24.9, "final_year_of_manufacture": 2013, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015163", "000207", "0", "2013/Aug/23 09:29", "Vaillant Group UK", "Glow-worm", "Betacom 24", "", "47-019-04", "2006", "2013", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.9", "24.9", "", "", "85.3", "76.7", "", "53.9", "", "2", "", "", "104", "1", "2", "145", "15", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "89.9", "", "", "", "", "89.5"]} +{"pcdb_id": 15164, "brand_name": "Glow-worm", "model_name": "Betacom 30", "model_qualifier": "", "winter_efficiency_pct": 85.6, "summer_efficiency_pct": 77.0, "comparative_hot_water_efficiency_pct": 54.2, "output_kw_max": 28.6, "final_year_of_manufacture": 2013, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015164", "000207", "0", "2013/Aug/23 09:30", "Vaillant Group UK", "Glow-worm", "Betacom 30", "", "47-019-05", "2006", "2013", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28.6", "28.6", "", "", "85.6", "77.0", "", "54.2", "", "2", "", "", "104", "1", "2", "150", "20", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.5", "91.0", "", "", "", "", "90.3"]} +{"pcdb_id": 15165, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "42 CDi", "winter_efficiency_pct": 89.8, "summer_efficiency_pct": 81.2, "comparative_hot_water_efficiency_pct": 63.4, "output_kw_max": 30.0, "final_year_of_manufacture": 2012, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015165", "000035", "0", "2020/Sep/08 09:27", "Worcester Bosch Group", "Worcester", "Greenstar", "42 CDi", "47-406-11", "2006", "2012", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "30", "30", "", "", "89.8", "81.2", "", "63.4", "", "2", "1", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "", "0305", "", "", "", "", "", "", "", "", "90.1", "101.0", "", "", "", "", "99.0"]} +{"pcdb_id": 15166, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "42 CDi", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 62.6, "output_kw_max": 30.0, "final_year_of_manufacture": 2012, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015166", "000035", "0", "2020/Sep/08 09:27", "Worcester Bosch Group", "Worcester", "Greenstar", "42 CDi", "47-406-10", "2006", "2012", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "30", "30", "", "", "88.8", "80.2", "", "62.6", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "", "0305", "", "", "", "", "", "", "", "", "88.1", "98.8", "", "", "", "", "96.8"]} +{"pcdb_id": 15168, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "37 CDi", "winter_efficiency_pct": 89.8, "summer_efficiency_pct": 81.2, "comparative_hot_water_efficiency_pct": 57.1, "output_kw_max": 30.0, "final_year_of_manufacture": 2012, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015168", "000035", "0", "2020/Sep/08 09:27", "Worcester Bosch Group", "Worcester", "Greenstar", "37 CDi", "47-406-09", "2006", "2012", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "30", "30", "", "", "89.8", "81.2", "", "57.1", "", "2", "1", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0305", "", "", "", "", "", "", "", "", "90.1", "101.0", "", "", "", "", "99.0"]} +{"pcdb_id": 15169, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "37 CDi", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 56.4, "output_kw_max": 30.0, "final_year_of_manufacture": 2012, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015169", "000035", "0", "2020/Sep/08 09:28", "Worcester Bosch Group", "Worcester", "Greenstar", "37 CDi", "47-406-08", "2006", "2012", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "30", "30", "", "", "88.8", "80.2", "", "56.4", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0305", "", "", "", "", "", "", "", "", "88.1", "98.8", "", "", "", "", "96.8"]} +{"pcdb_id": 15170, "brand_name": "Sime", "model_name": "Ecomfort", "model_qualifier": "25 HE", "winter_efficiency_pct": 86.3, "summer_efficiency_pct": 77.7, "comparative_hot_water_efficiency_pct": 54.7, "output_kw_max": 24.7, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015170", "000213", "0", "2018/Feb/26 16:40", "Fonderie Sime S.p.A.", "Sime", "Ecomfort", "25 HE", "", "2006", "2018", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "24.7", "24.7", "", "", "86.3", "77.7", "", "54.7", "", "2", "", "", "104", "1", "2", "180", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.4", "92.8", "", "", "", "", "91.8"]} +{"pcdb_id": 15171, "brand_name": "Sime", "model_name": "Ecomfort", "model_qualifier": "25 HE", "winter_efficiency_pct": 87.3, "summer_efficiency_pct": 78.7, "comparative_hot_water_efficiency_pct": 55.3, "output_kw_max": 24.7, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015171", "000213", "0", "2018/Feb/26 16:40", "Fonderie Sime S.p.A.", "Sime", "Ecomfort", "25 HE", "", "2006", "2018", "2", "2", "1", "2", "0", "", "", "2", "3", "2", "24.7", "24.7", "", "", "87.3", "78.7", "", "55.3", "", "2", "1", "", "104", "1", "2", "180", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.3", "94.9", "", "", "", "", "93.8"]} +{"pcdb_id": 15172, "brand_name": "Ravenheat", "model_name": "CSI Primary AAA", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 22.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015172", "000026", "0", "2012/Mar/27 10:12", "Ravenheat Manufacturing", "Ravenheat", "CSI Primary AAA", "", "", "2006", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "22.3", "22.3", "", "", "88.6", "79.6", "", "58.1", "", "2", "1", "", "102", "1", "2", "160", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.9", "97.5", "", "", "", "", "96.3"]} +{"pcdb_id": 15173, "brand_name": "Ravenheat", "model_name": "CSI Primary AAA", "model_qualifier": "", "winter_efficiency_pct": 87.6, "summer_efficiency_pct": 78.6, "comparative_hot_water_efficiency_pct": 57.4, "output_kw_max": 22.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015173", "000026", "0", "2012/Mar/27 10:12", "Ravenheat Manufacturing", "Ravenheat", "CSI Primary AAA", "", "", "2006", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "22.3", "22.3", "", "", "87.6", "78.6", "", "57.4", "", "2", "", "", "102", "1", "2", "160", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.9", "95.4", "", "", "", "", "94.2"]} +{"pcdb_id": 15174, "brand_name": "Ravenheat", "model_name": "HE Primary AAA", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 22.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015174", "000026", "0", "2012/Mar/27 10:12", "Ravenheat Manufacturing", "Ravenheat", "HE Primary AAA", "", "", "2006", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "22.3", "22.3", "", "", "88.6", "79.6", "", "58.1", "", "2", "1", "", "102", "1", "2", "160", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.9", "97.5", "", "", "", "", "96.3"]} +{"pcdb_id": 15175, "brand_name": "Ravenheat", "model_name": "HE Primary AAA", "model_qualifier": "", "winter_efficiency_pct": 87.6, "summer_efficiency_pct": 78.6, "comparative_hot_water_efficiency_pct": 57.4, "output_kw_max": 22.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015175", "000026", "0", "2012/Mar/27 10:12", "Ravenheat Manufacturing", "Ravenheat", "HE Primary AAA", "", "", "2006", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "22.3", "22.3", "", "", "87.6", "78.6", "", "57.4", "", "2", "", "", "102", "1", "2", "160", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.9", "95.4", "", "", "", "", "94.2"]} +{"pcdb_id": 15176, "brand_name": "Ravenheat", "model_name": "HE System AAA T", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 22.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015176", "000026", "0", "2012/Mar/27 10:12", "Ravenheat Manufacturing", "Ravenheat", "HE System AAA T", "", "", "2006", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "22.3", "22.3", "", "", "88.6", "79.6", "", "58.1", "", "2", "1", "", "102", "1", "2", "160", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.9", "97.5", "", "", "", "", "96.3"]} +{"pcdb_id": 15177, "brand_name": "Ravenheat", "model_name": "HE System AAA T", "model_qualifier": "", "winter_efficiency_pct": 87.6, "summer_efficiency_pct": 78.6, "comparative_hot_water_efficiency_pct": 57.4, "output_kw_max": 22.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015177", "000026", "0", "2012/Mar/27 10:12", "Ravenheat Manufacturing", "Ravenheat", "HE System AAA T", "", "", "2006", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "22.3", "22.3", "", "", "87.6", "78.6", "", "57.4", "", "2", "", "", "102", "1", "2", "160", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.9", "95.4", "", "", "", "", "94.2"]} +{"pcdb_id": 15178, "brand_name": "Ravenheat", "model_name": "HE System AAA", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 22.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015178", "000026", "0", "2012/Mar/27 10:12", "Ravenheat Manufacturing", "Ravenheat", "HE System AAA", "", "", "2006", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "22.3", "22.3", "", "", "88.6", "79.6", "", "58.1", "", "2", "1", "", "102", "1", "2", "160", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.9", "97.5", "", "", "", "", "96.3"]} +{"pcdb_id": 15179, "brand_name": "Ravenheat", "model_name": "HE System AAA", "model_qualifier": "", "winter_efficiency_pct": 87.6, "summer_efficiency_pct": 78.6, "comparative_hot_water_efficiency_pct": 57.4, "output_kw_max": 22.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015179", "000026", "0", "2012/Mar/27 10:12", "Ravenheat Manufacturing", "Ravenheat", "HE System AAA", "", "", "2006", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "22.3", "22.3", "", "", "87.6", "78.6", "", "57.4", "", "2", "", "", "102", "1", "2", "160", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.9", "95.4", "", "", "", "", "94.2"]} +{"pcdb_id": 15180, "brand_name": "Ravenheat", "model_name": "CSI System AAA T", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 22.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015180", "000026", "0", "2012/Mar/27 10:12", "Ravenheat Manufacturing", "Ravenheat", "CSI System AAA T", "", "", "2006", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "22.3", "22.3", "", "", "88.6", "79.6", "", "58.1", "", "2", "1", "", "102", "1", "2", "160", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.9", "97.5", "", "", "", "", "96.3"]} +{"pcdb_id": 15181, "brand_name": "Ravenheat", "model_name": "CSI System AAA T", "model_qualifier": "", "winter_efficiency_pct": 87.6, "summer_efficiency_pct": 78.6, "comparative_hot_water_efficiency_pct": 57.4, "output_kw_max": 22.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015181", "000026", "0", "2012/Mar/27 10:12", "Ravenheat Manufacturing", "Ravenheat", "CSI System AAA T", "", "", "2006", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "22.3", "22.3", "", "", "87.6", "78.6", "", "57.4", "", "2", "", "", "102", "1", "2", "160", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.9", "95.4", "", "", "", "", "94.2"]} +{"pcdb_id": 15182, "brand_name": "Ravenheat", "model_name": "CSI System AAA", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 22.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015182", "000026", "0", "2012/Mar/27 10:12", "Ravenheat Manufacturing", "Ravenheat", "CSI System AAA", "", "", "2006", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "22.3", "22.3", "", "", "88.6", "79.6", "", "58.1", "", "2", "1", "", "102", "1", "2", "160", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.9", "97.5", "", "", "", "", "96.3"]} +{"pcdb_id": 15183, "brand_name": "Ravenheat", "model_name": "CSI System AAA", "model_qualifier": "", "winter_efficiency_pct": 87.6, "summer_efficiency_pct": 78.6, "comparative_hot_water_efficiency_pct": 57.4, "output_kw_max": 22.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015183", "000026", "0", "2012/Mar/27 10:12", "Ravenheat Manufacturing", "Ravenheat", "CSI System AAA", "", "", "2006", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "22.3", "22.3", "", "", "87.6", "78.6", "", "57.4", "", "2", "", "", "102", "1", "2", "160", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.9", "95.4", "", "", "", "", "94.2"]} +{"pcdb_id": 15184, "brand_name": "Ravenheat", "model_name": "HE 85 AAA", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 56.3, "output_kw_max": 22.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015184", "000026", "0", "2010/Sep/29 12:23", "Ravenheat Manufacturing", "Ravenheat", "HE 85 AAA", "", "", "2006", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "22.3", "22.3", "", "", "88.6", "80.0", "", "56.3", "", "2", "1", "", "104", "1", "2", "160", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.9", "97.5", "", "", "", "", "96.3"]} +{"pcdb_id": 15185, "brand_name": "Ravenheat", "model_name": "HE 85 AAA", "model_qualifier": "", "winter_efficiency_pct": 87.6, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 55.6, "output_kw_max": 22.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015185", "000026", "0", "2010/Sep/29 12:18", "Ravenheat Manufacturing", "Ravenheat", "HE 85 AAA", "", "", "2006", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "22.3", "22.3", "", "", "87.6", "79.0", "", "55.6", "", "2", "", "", "104", "1", "2", "160", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.9", "95.4", "", "", "", "", "94.2"]} +{"pcdb_id": 15186, "brand_name": "Ravenheat", "model_name": "HE 85 AAAT", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 56.3, "output_kw_max": 22.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015186", "000026", "0", "2010/Sep/29 12:23", "Ravenheat Manufacturing", "Ravenheat", "HE 85 AAAT", "", "", "2006", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "22.3", "22.3", "", "", "88.6", "80.0", "", "56.3", "", "2", "1", "", "104", "1", "2", "160", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.9", "97.5", "", "", "", "", "96.3"]} +{"pcdb_id": 15187, "brand_name": "Ravenheat", "model_name": "HE 85 AAAT", "model_qualifier": "", "winter_efficiency_pct": 87.6, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 55.6, "output_kw_max": 22.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015187", "000026", "0", "2010/Sep/29 12:18", "Ravenheat Manufacturing", "Ravenheat", "HE 85 AAAT", "", "", "2006", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "22.3", "22.3", "", "", "87.6", "79.0", "", "55.6", "", "2", "", "", "104", "1", "2", "160", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.9", "95.4", "", "", "", "", "94.2"]} +{"pcdb_id": 15188, "brand_name": "Ravenheat", "model_name": "CSI 85 AAAT", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 56.3, "output_kw_max": 22.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015188", "000026", "0", "2010/Sep/29 12:24", "Ravenheat Manufacturing", "Ravenheat", "CSI 85 AAAT", "", "", "2006", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "22.3", "22.3", "", "", "88.6", "80.0", "", "56.3", "", "2", "1", "", "104", "1", "2", "160", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.9", "97.5", "", "", "", "", "96.3"]} +{"pcdb_id": 15189, "brand_name": "Ravenheat", "model_name": "CSI 85 AAAT", "model_qualifier": "", "winter_efficiency_pct": 87.6, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 55.6, "output_kw_max": 22.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015189", "000026", "0", "2010/Sep/29 12:18", "Ravenheat Manufacturing", "Ravenheat", "CSI 85 AAAT", "", "", "2006", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "22.3", "22.3", "", "", "87.6", "79.0", "", "55.6", "", "2", "", "", "104", "1", "2", "160", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.9", "95.4", "", "", "", "", "94.2"]} +{"pcdb_id": 15190, "brand_name": "Ravenheat", "model_name": "CSI 85 AAA", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 56.3, "output_kw_max": 22.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015190", "000026", "0", "2010/Sep/29 12:24", "Ravenheat Manufacturing", "Ravenheat", "CSI 85 AAA", "", "", "2006", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "22.3", "22.3", "", "", "88.6", "80.0", "", "56.3", "", "2", "1", "", "104", "1", "2", "160", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.9", "97.5", "", "", "", "", "96.3"]} +{"pcdb_id": 15191, "brand_name": "Ravenheat", "model_name": "CSI 85 AAA", "model_qualifier": "", "winter_efficiency_pct": 87.6, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 55.6, "output_kw_max": 22.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015191", "000026", "0", "2010/Sep/29 12:20", "Ravenheat Manufacturing", "Ravenheat", "CSI 85 AAA", "", "", "2006", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "22.3", "22.3", "", "", "87.6", "79.0", "", "55.6", "", "2", "", "", "104", "1", "2", "160", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.9", "95.4", "", "", "", "", "94.2"]} +{"pcdb_id": 15193, "brand_name": "Ferroli", "model_name": "Optimax", "model_qualifier": "HE 38 C", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 56.3, "output_kw_max": 30.2, "final_year_of_manufacture": 2008, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015193", "000097", "0", "2010/Sep/29 12:21", "Ferroli SpA", "Ferroli", "Optimax", "HE 38 C", "", "2006", "2008", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "30.2", "30.2", "", "", "88.7", "80.1", "", "56.3", "", "2", "", "", "104", "1", "2", "145", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.7", "98.3", "", "", "", "", "96.5"]} +{"pcdb_id": 15194, "brand_name": "Ferroli", "model_name": "Optimax", "model_qualifier": "HE 25 S", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 24.6, "final_year_of_manufacture": 2008, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015194", "000097", "0", "2012/Mar/27 10:12", "Ferroli SpA", "Ferroli", "Optimax", "HE 25 S", "", "2006", "2008", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24.6", "24.6", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "120", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.6", "97.6", "", "", "", "", "95.9"]} +{"pcdb_id": 15195, "brand_name": "Ferroli", "model_name": "Optimax", "model_qualifier": "HE 31 C", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 56.1, "output_kw_max": 24.6, "final_year_of_manufacture": 2008, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015195", "000097", "0", "2009/Apr/28 16:02", "Ferroli SpA", "Ferroli", "Optimax", "HE 31 C", "", "2006", "2008", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.6", "24.6", "", "", "88.4", "79.8", "", "56.1", "", "2", "", "", "104", "1", "2", "135", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.6", "97.6", "", "", "", "", "95.9"]} +{"pcdb_id": 15198, "brand_name": "Glow-worm", "model_name": "Ultrapower 100 SXI", "model_qualifier": "", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 80.9, "comparative_hot_water_efficiency_pct": 54.5, "output_kw_max": 24.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015198", "000207", "0", "2024/Jan/31 10:17", "Vaillant Group UK", "Glow-worm", "Ultrapower 100 SXI", "", "41-019-09", "2007", "current", "1", "1", "1", "2", "0", "", "", "2", "2", "2", "24.3", "24.3", "", "", "88.2", "80.9", "", "54.5", "", "2", "", "", "106", "1", "2", "180", "15", "2", "1", "0", "80", "0", "50", "5", "62", "0.57", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.0", "96.4", "", "", "", "", "95.2"]} +{"pcdb_id": 15199, "brand_name": "Glow-worm", "model_name": "Ultrapower 170 SXI", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 51.3, "output_kw_max": 24.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015199", "000207", "0", "2024/Jan/31 10:17", "Vaillant Group UK", "Glow-worm", "Ultrapower 170 SXI", "", "41-019-10", "2007", "current", "1", "1", "1", "2", "0", "", "", "2", "2", "2", "24.3", "24.3", "", "", "88.3", "81.0", "", "51.3", "", "2", "", "", "106", "1", "2", "180", "15", "2", "1", "0", "120", "0", "50", "5", "62", "0.57", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.0", "96.8", "", "", "", "", "95.5"]} +{"pcdb_id": 15200, "brand_name": "Biasi", "model_name": "Riva Compact HE", "model_qualifier": "M96.24SM/C2", "winter_efficiency_pct": 85.8, "summer_efficiency_pct": 77.2, "comparative_hot_water_efficiency_pct": 54.3, "output_kw_max": 24.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015200", "000208", "0", "2007/Jun/22 10:59", "Biasi SpA", "Biasi", "Riva Compact HE", "M96.24SM/C2", "47-583-05", "2006", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.6", "24.6", "", "", "85.8", "77.2", "", "54.3", "", "2", "", "", "104", "1", "2", "140", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.7", "90.9", "", "", "", "", "90.5"]} +{"pcdb_id": 15201, "brand_name": "Biasi", "model_name": "Riva Compact HE", "model_qualifier": "M96.24SM/C2", "winter_efficiency_pct": 86.2, "summer_efficiency_pct": 77.6, "comparative_hot_water_efficiency_pct": 54.5, "output_kw_max": 23.7, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015201", "000208", "0", "2007/Jun/22 11:01", "Biasi SpA", "Biasi", "Riva Compact HE", "M96.24SM/C2", "", "2006", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "23.7", "23.7", "", "", "86.2", "77.6", "", "54.5", "", "2", "0", "", "104", "1", "2", "140", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.3", "90.8", "", "", "", "", "90.1"]} +{"pcdb_id": 15202, "brand_name": "Biasi", "model_name": "Garda HE", "model_qualifier": "M96.28SM/D2", "winter_efficiency_pct": 85.9, "summer_efficiency_pct": 77.3, "comparative_hot_water_efficiency_pct": 54.4, "output_kw_max": 28.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015202", "000208", "0", "2007/Jun/22 10:38", "Biasi SpA", "Biasi", "Garda HE", "M96.28SM/D2", "", "2006", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28.3", "28.3", "", "", "85.9", "77.3", "", "54.4", "", "2", "", "", "104", "1", "2", "150", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "91.5", "", "", "", "", "90.8"]} +{"pcdb_id": 15203, "brand_name": "Biasi", "model_name": "Garda HE", "model_qualifier": "M96.28SM/D2", "winter_efficiency_pct": 86.3, "summer_efficiency_pct": 77.7, "comparative_hot_water_efficiency_pct": 54.6, "output_kw_max": 27.4, "final_year_of_manufacture": 2007, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015203", "000208", "0", "2008/May/22 11:56", "Biasi SpA", "Biasi", "Garda HE", "M96.28SM/D2", "", "2006", "2007", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "27.4", "27.4", "", "", "86.3", "77.7", "", "54.6", "", "2", "0", "", "104", "1", "2", "150", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.1", "91.4", "", "", "", "", "90.6"]} +{"pcdb_id": 15204, "brand_name": "Biasi", "model_name": "Riva Compact HE", "model_qualifier": "M96.28SM/C2", "winter_efficiency_pct": 85.9, "summer_efficiency_pct": 77.3, "comparative_hot_water_efficiency_pct": 54.4, "output_kw_max": 28.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015204", "000208", "0", "2007/Jun/22 10:51", "Biasi SpA", "Biasi", "Riva Compact HE", "M96.28SM/C2", "47-583-06", "2006", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28.3", "28.3", "", "", "85.9", "77.3", "", "54.4", "", "2", "", "", "104", "1", "2", "150", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "91.5", "", "", "", "", "90.8"]} +{"pcdb_id": 15205, "brand_name": "Biasi", "model_name": "Riva Compact HE", "model_qualifier": "M96.28SM/C2", "winter_efficiency_pct": 86.3, "summer_efficiency_pct": 77.7, "comparative_hot_water_efficiency_pct": 54.6, "output_kw_max": 27.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015205", "000208", "0", "2007/Jun/22 10:52", "Biasi SpA", "Biasi", "Riva Compact HE", "M96.28SM/C2", "", "2006", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "27.4", "27.4", "", "", "86.3", "77.7", "", "54.6", "", "2", "0", "", "104", "1", "2", "150", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.1", "91.4", "", "", "", "", "90.6"]} +{"pcdb_id": 15206, "brand_name": "Biasi", "model_name": "Garda HE", "model_qualifier": "M96.28SM/B2", "winter_efficiency_pct": 85.9, "summer_efficiency_pct": 77.3, "comparative_hot_water_efficiency_pct": 54.4, "output_kw_max": 28.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015206", "000208", "0", "2007/Jun/22 10:37", "Biasi SpA", "Biasi", "Garda HE", "M96.28SM/B2", "", "2006", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28.3", "28.3", "", "", "85.9", "77.3", "", "54.4", "", "2", "", "", "104", "1", "2", "150", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "91.5", "", "", "", "", "90.8"]} +{"pcdb_id": 15207, "brand_name": "Biasi", "model_name": "Garda HE", "model_qualifier": "M96.28SM/B2", "winter_efficiency_pct": 86.3, "summer_efficiency_pct": 77.7, "comparative_hot_water_efficiency_pct": 54.6, "output_kw_max": 27.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015207", "000208", "0", "2007/Jun/22 10:38", "Biasi SpA", "Biasi", "Garda HE", "M96.28SM/B2", "", "2006", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "27.4", "27.4", "", "", "86.3", "77.7", "", "54.6", "", "2", "0", "", "104", "1", "2", "150", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.1", "91.4", "", "", "", "", "90.6"]} +{"pcdb_id": 15208, "brand_name": "Biasi", "model_name": "Garda HE", "model_qualifier": "M96.24SM/B2", "winter_efficiency_pct": 85.8, "summer_efficiency_pct": 77.2, "comparative_hot_water_efficiency_pct": 54.3, "output_kw_max": 24.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015208", "000208", "0", "2007/Jun/22 10:36", "Biasi SpA", "Biasi", "Garda HE", "M96.24SM/B2", "", "2006", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.6", "24.6", "", "", "85.8", "77.2", "", "54.3", "", "2", "", "", "104", "1", "2", "140", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.7", "90.9", "", "", "", "", "90.5"]} +{"pcdb_id": 15209, "brand_name": "Biasi", "model_name": "Garda HE", "model_qualifier": "M96.24SM/B2", "winter_efficiency_pct": 86.2, "summer_efficiency_pct": 77.6, "comparative_hot_water_efficiency_pct": 54.5, "output_kw_max": 23.7, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015209", "000208", "0", "2007/Jun/22 10:37", "Biasi SpA", "Biasi", "Garda HE", "M96.24SM/B2", "", "2006", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "23.7", "23.7", "", "", "86.2", "77.6", "", "54.5", "", "2", "0", "", "104", "1", "2", "140", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.3", "90.8", "", "", "", "", "90.1"]} +{"pcdb_id": 15210, "brand_name": "Biasi", "model_name": "Riva Compact HE", "model_qualifier": "M96.28SR/C2", "winter_efficiency_pct": 85.9, "summer_efficiency_pct": 76.9, "comparative_hot_water_efficiency_pct": 56.2, "output_kw_max": 28.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015210", "000208", "0", "2012/Mar/27 10:12", "Biasi SpA", "Biasi", "Riva Compact HE", "M96.28SR/C2", "41-583-02", "2006", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "28.3", "28.3", "", "", "85.9", "76.9", "", "56.2", "", "2", "", "", "102", "1", "2", "150", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "91.5", "", "", "", "", "90.8"]} +{"pcdb_id": 15211, "brand_name": "Biasi", "model_name": "Riva Compact HE", "model_qualifier": "M96.28SR/C2", "winter_efficiency_pct": 86.3, "summer_efficiency_pct": 77.3, "comparative_hot_water_efficiency_pct": 56.5, "output_kw_max": 27.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015211", "000208", "0", "2012/Mar/27 10:12", "Biasi SpA", "Biasi", "Riva Compact HE", "M96.28SR/C2", "", "2006", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "27.4", "27.4", "", "", "86.3", "77.3", "", "56.5", "", "2", "0", "", "102", "1", "2", "150", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.1", "91.4", "", "", "", "", "90.6"]} +{"pcdb_id": 15212, "brand_name": "Biasi", "model_name": "Riva Compact HE", "model_qualifier": "M96.32SM/C2", "winter_efficiency_pct": 85.5, "summer_efficiency_pct": 76.9, "comparative_hot_water_efficiency_pct": 54.1, "output_kw_max": 32.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015212", "000208", "0", "2007/Jun/22 10:52", "Biasi SpA", "Biasi", "Riva Compact HE", "M96.32SM/C2", "47-583-07", "2006", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "32.2", "32.2", "", "", "85.5", "76.9", "", "54.1", "", "2", "", "", "104", "1", "2", "150", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.1", "90.7", "", "", "", "", "90.0"]} +{"pcdb_id": 15213, "brand_name": "Biasi", "model_name": "Riva Compact HE", "model_qualifier": "M96.32SM/C2", "winter_efficiency_pct": 87.4, "summer_efficiency_pct": 78.8, "comparative_hot_water_efficiency_pct": 55.4, "output_kw_max": 32.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015213", "000208", "0", "2007/Jun/22 10:53", "Biasi SpA", "Biasi", "Riva Compact HE", "M96.32SM/C2", "", "2006", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "32.2", "32.2", "", "", "87.4", "78.8", "", "55.4", "", "2", "0", "", "104", "1", "2", "150", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.1", "92.7", "", "", "", "", "92.0"]} +{"pcdb_id": 15214, "brand_name": "Biasi", "model_name": "Garda HE Silver", "model_qualifier": "M96.24SM/D2", "winter_efficiency_pct": 85.8, "summer_efficiency_pct": 77.2, "comparative_hot_water_efficiency_pct": 54.3, "output_kw_max": 24.6, "final_year_of_manufacture": 2008, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015214", "000208", "0", "2008/May/22 11:21", "Biasi SpA", "Biasi", "Garda HE Silver", "M96.24SM/D2", "47-583-03B", "2006", "2008", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.6", "24.6", "", "", "85.8", "77.2", "", "54.3", "", "2", "", "", "104", "1", "2", "140", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.7", "90.9", "", "", "", "", "90.5"]} +{"pcdb_id": 15215, "brand_name": "Biasi", "model_name": "Garda HE Silver", "model_qualifier": "M96.24SM/D2", "winter_efficiency_pct": 86.2, "summer_efficiency_pct": 77.6, "comparative_hot_water_efficiency_pct": 54.5, "output_kw_max": 23.7, "final_year_of_manufacture": 2008, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015215", "000208", "0", "2008/May/22 11:22", "Biasi SpA", "Biasi", "Garda HE Silver", "M96.24SM/D2", "", "2006", "2008", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "23.7", "23.7", "", "", "86.2", "77.6", "", "54.5", "", "2", "0", "", "104", "1", "2", "140", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.3", "90.8", "", "", "", "", "90.1"]} +{"pcdb_id": 15223, "brand_name": "Worcester", "model_name": "Greenstar Camray", "model_qualifier": "12/18", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 58.7, "output_kw_max": 18.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015223", "000035", "0", "2020/Sep/08 09:29", "Worcester Bosch Group", "Worcester", "Greenstar Camray", "12/18", "", "2007", "2015", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "12", "18", "", "", "88.1", "80.3", "", "58.7", "", "2", "", "", "201", "1", "1", "150", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.4", "94.8", "", "", "", "", "94.2"]} +{"pcdb_id": 15224, "brand_name": "Worcester", "model_name": "Greenstar Camray", "model_qualifier": "18/25", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 80.6, "comparative_hot_water_efficiency_pct": 58.9, "output_kw_max": 25.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015224", "000035", "0", "2020/Sep/08 09:29", "Worcester Bosch Group", "Worcester", "Greenstar Camray", "18/25", "", "2007", "2015", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "18", "25", "", "", "88.4", "80.6", "", "58.9", "", "2", "", "", "201", "1", "1", "160", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.5", "95.9", "", "", "", "", "94.8"]} +{"pcdb_id": 15225, "brand_name": "Worcester", "model_name": "Greenstar Camray", "model_qualifier": "25/32", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 81.1, "comparative_hot_water_efficiency_pct": 59.3, "output_kw_max": 30.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015225", "000035", "0", "2020/Sep/08 09:29", "Worcester Bosch Group", "Worcester", "Greenstar Camray", "25/32", "", "2007", "2015", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "25", "30", "", "", "88.9", "81.1", "", "59.3", "", "2", "", "", "201", "1", "1", "160", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.5", "96.9", "", "", "", "", "95.9"]} +{"pcdb_id": 15226, "brand_name": "Worcester", "model_name": "Greenstar Camray Utility System", "model_qualifier": "12/18", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 58.7, "output_kw_max": 18.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015226", "000035", "0", "2020/Sep/08 09:29", "Worcester Bosch Group", "Worcester", "Greenstar Camray Utility System", "12/18", "", "2007", "2015", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "12", "18", "", "", "88.1", "80.3", "", "58.7", "", "2", "", "", "201", "1", "2", "255", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "91.4", "94.8", "", "", "", "", "94.2"]} +{"pcdb_id": 15227, "brand_name": "Worcester", "model_name": "Greenstar Camray Utility System", "model_qualifier": "18/25", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 80.6, "comparative_hot_water_efficiency_pct": 58.9, "output_kw_max": 25.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015227", "000035", "0", "2020/Sep/08 09:30", "Worcester Bosch Group", "Worcester", "Greenstar Camray Utility System", "18/25", "", "2007", "2015", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "18", "25", "", "", "88.4", "80.6", "", "58.9", "", "2", "", "", "201", "1", "1", "265", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.5", "95.9", "", "", "", "", "94.8"]} +{"pcdb_id": 15228, "brand_name": "Worcester", "model_name": "Greenstar Camray Utility System", "model_qualifier": "25/32", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 81.1, "comparative_hot_water_efficiency_pct": 59.3, "output_kw_max": 30.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015228", "000035", "0", "2020/Sep/08 09:30", "Worcester Bosch Group", "Worcester", "Greenstar Camray Utility System", "25/32", "", "2007", "2015", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "25", "30", "", "", "88.9", "81.1", "", "59.3", "", "2", "", "", "201", "1", "1", "265", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.5", "96.9", "", "", "", "", "95.9"]} +{"pcdb_id": 15229, "brand_name": "Worcester", "model_name": "Greenstar Camray Utility", "model_qualifier": "12/18", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 58.7, "output_kw_max": 18.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015229", "000035", "0", "2020/Sep/08 09:30", "Worcester Bosch Group", "Worcester", "Greenstar Camray Utility", "12/18", "", "2007", "2015", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "12", "18", "", "", "88.1", "80.3", "", "58.7", "", "2", "", "", "201", "1", "1", "150", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.4", "94.8", "", "", "", "", "94.2"]} +{"pcdb_id": 15230, "brand_name": "Worcester", "model_name": "Greenstar Camray Utility", "model_qualifier": "18/25", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 80.6, "comparative_hot_water_efficiency_pct": 58.9, "output_kw_max": 25.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015230", "000035", "0", "2020/Sep/08 09:30", "Worcester Bosch Group", "Worcester", "Greenstar Camray Utility", "18/25", "", "2007", "2015", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "18", "25", "", "", "88.4", "80.6", "", "58.9", "", "2", "", "", "201", "1", "1", "160", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.5", "95.9", "", "", "", "", "94.8"]} +{"pcdb_id": 15231, "brand_name": "Worcester", "model_name": "Greenstar Camray Utility", "model_qualifier": "25/32", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 81.1, "comparative_hot_water_efficiency_pct": 59.3, "output_kw_max": 30.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015231", "000035", "0", "2020/Sep/08 09:30", "Worcester Bosch Group", "Worcester", "Greenstar Camray Utility", "25/32", "", "2007", "2015", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "25", "30", "", "", "88.9", "81.1", "", "59.3", "", "2", "", "", "201", "1", "1", "160", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.5", "96.9", "", "", "", "", "95.9"]} +{"pcdb_id": 15232, "brand_name": "Worcester", "model_name": "Greenstar Camray External", "model_qualifier": "12/18", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 58.7, "output_kw_max": 18.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015232", "000035", "0", "2020/Sep/08 09:34", "Worcester Bosch Group", "Worcester", "Greenstar Camray External", "12/18", "", "2007", "2015", "4", "1", "2", "1", "0", "", "", "2", "2", "2", "12", "18", "", "", "88.1", "80.3", "", "58.7", "", "2", "", "", "201", "1", "1", "150", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.4", "94.8", "", "", "", "", "94.2"]} +{"pcdb_id": 15233, "brand_name": "Worcester", "model_name": "Greenstar Camray External", "model_qualifier": "18/25", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 80.6, "comparative_hot_water_efficiency_pct": 58.9, "output_kw_max": 25.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015233", "000035", "0", "2020/Sep/08 09:34", "Worcester Bosch Group", "Worcester", "Greenstar Camray External", "18/25", "", "2007", "2015", "4", "1", "2", "1", "0", "", "", "2", "2", "2", "18", "25", "", "", "88.4", "80.6", "", "58.9", "", "2", "", "", "201", "1", "2", "160", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.5", "95.9", "", "", "", "", "94.8"]} +{"pcdb_id": 15234, "brand_name": "Worcester", "model_name": "Greenstar Camray External", "model_qualifier": "25/32", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 81.1, "comparative_hot_water_efficiency_pct": 59.3, "output_kw_max": 30.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015234", "000035", "0", "2020/Sep/08 09:50", "Worcester Bosch Group", "Worcester", "Greenstar Camray External", "25/32", "", "2007", "2015", "4", "1", "2", "1", "0", "", "", "2", "2", "2", "25", "30", "", "", "88.9", "81.1", "", "59.3", "", "2", "", "", "201", "1", "1", "160", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.5", "96.9", "", "", "", "", "95.9"]} +{"pcdb_id": 15235, "brand_name": "Worcester", "model_name": "Greenstar Heatslave External", "model_qualifier": "12/18", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 82.1, "comparative_hot_water_efficiency_pct": 41.6, "output_kw_max": 18.0, "final_year_of_manufacture": 2013, "subsidiary_type": 0, "store_type": 1, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015235", "000035", "0", "2024/Jan/31 10:17", "Worcester Bosch Group", "Worcester", "Greenstar Heatslave External", "12/18", "", "2007", "2013", "4", "1", "2", "2", "0", "", "", "2", "2", "2", "12", "18", "", "", "88.2", "82.1", "", "41.6", "", "2", "", "", "203", "1", "1", "240", "0", "1", "1", "0", "69", "0", "25", "3", "82", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.6", "95.3", "", "", "", "", "94.4"]} +{"pcdb_id": 15236, "brand_name": "Worcester", "model_name": "Greenstar Heatslave External", "model_qualifier": "18/25", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 81.9, "comparative_hot_water_efficiency_pct": 41.6, "output_kw_max": 25.0, "final_year_of_manufacture": 2013, "subsidiary_type": 0, "store_type": 1, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015236", "000035", "0", "2024/Jan/31 10:17", "Worcester Bosch Group", "Worcester", "Greenstar Heatslave External", "18/25", "", "2007", "2013", "4", "1", "2", "2", "0", "", "", "2", "2", "2", "18", "25", "", "", "88.0", "81.9", "", "41.6", "", "2", "", "", "203", "1", "1", "240", "0", "1", "1", "0", "69", "0", "25", "3", "82", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.0", "94.7", "", "", "", "", "94.0"]} +{"pcdb_id": 15237, "brand_name": "Worcester", "model_name": "Greenstar Heatslave External", "model_qualifier": "25/32", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 81.9, "comparative_hot_water_efficiency_pct": 41.6, "output_kw_max": 32.0, "final_year_of_manufacture": 2013, "subsidiary_type": 0, "store_type": 1, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015237", "000035", "0", "2024/Jan/31 10:17", "Worcester Bosch Group", "Worcester", "Greenstar Heatslave External", "25/32", "", "2007", "2013", "4", "1", "2", "2", "0", "", "", "2", "2", "2", "25", "32", "", "", "88.0", "81.9", "", "41.6", "", "2", "", "", "203", "1", "1", "263", "0", "1", "1", "0", "69", "0", "25", "3", "82", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.8", "94.4", "", "", "", "", "93.9"]} +{"pcdb_id": 15238, "brand_name": "Potterton", "model_name": "Promax SL", "model_qualifier": "30", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 30.18, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015238", "000005", "0", "2012/Mar/27 10:12", "Baxi Heating", "Potterton", "Promax SL", "30", "GC No. 41-591-89", "2007", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "30.18", "30.18", "", "", "88.1", "79.1", "", "57.8", "", "2", "", "", "102", "1", "2", "80", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.4", "96.4", "", "", "", "", "95.1"]} +{"pcdb_id": 15239, "brand_name": "Potterton", "model_name": "Promax SL", "model_qualifier": "24", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 22.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015239", "000005", "0", "2012/Mar/27 10:12", "Baxi Heating", "Potterton", "Promax SL", "24", "GC No. 41-591-88", "2007", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "22.00", "22.00", "", "", "88.1", "79.1", "", "57.8", "", "2", "", "", "102", "1", "2", "80", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.5", "96.5", "", "", "", "", "95.2"]} +{"pcdb_id": 15240, "brand_name": "Potterton", "model_name": "Promax SL", "model_qualifier": "18", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 17.81, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015240", "000005", "0", "2012/Mar/27 10:12", "Baxi Heating", "Potterton", "Promax SL", "18", "GC No. 41-591-80", "2007", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "17.81", "17.81", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "80", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "96.8", "", "", "", "", "95.2"]} +{"pcdb_id": 15241, "brand_name": "Potterton", "model_name": "Promax SL", "model_qualifier": "15", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 15.24, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015241", "000005", "0", "2012/Mar/27 10:12", "Baxi Heating", "Potterton", "Promax SL", "15", "GC No. 41-591-87", "2007", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "15.24", "15.24", "", "", "88.3", "79.3", "", "57.9", "", "2", "", "", "102", "1", "2", "80", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.3", "96.5", "", "", "", "", "95.3"]} +{"pcdb_id": 15242, "brand_name": "Potterton", "model_name": "Promax SL", "model_qualifier": "12", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 11.82, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015242", "000005", "0", "2012/Mar/27 10:12", "Baxi Heating", "Potterton", "Promax SL", "12", "GC No. 41-591-79", "2007", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "11.82", "11.82", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "80", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.6", "96.5", "", "", "", "", "95.0"]} +{"pcdb_id": 15243, "brand_name": "Main", "model_name": "System", "model_qualifier": "18 HE", "winter_efficiency_pct": 86.0, "summer_efficiency_pct": 77.0, "comparative_hot_water_efficiency_pct": 56.2, "output_kw_max": 18.0, "final_year_of_manufacture": 2011, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015243", "000005", "0", "2013/May/07 10:32", "Baxi Heating", "Main", "System", "18 HE", "GC No. 41-467-04", "2006", "2011", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18.0", "18.0", "", "", "86.0", "77.0", "", "56.2", "", "2", "", "", "102", "1", "2", "140", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "86.6", "92.3", "", "", "", "", "91.2"]} +{"pcdb_id": 15244, "brand_name": "Main", "model_name": "System", "model_qualifier": "24 HE", "winter_efficiency_pct": 85.8, "summer_efficiency_pct": 76.8, "comparative_hot_water_efficiency_pct": 56.1, "output_kw_max": 24.0, "final_year_of_manufacture": 2011, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015244", "000005", "0", "2013/May/07 10:33", "Baxi Heating", "Main", "System", "24 HE", "GC No. 41-467-02", "2006", "2011", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24.0", "24.0", "", "", "85.8", "76.8", "", "56.1", "", "2", "", "", "102", "1", "2", "170", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.2", "91.5", "", "", "", "", "90.7"]} +{"pcdb_id": 15245, "brand_name": "Main", "model_name": "System", "model_qualifier": "28 HE", "winter_efficiency_pct": 85.7, "summer_efficiency_pct": 76.7, "comparative_hot_water_efficiency_pct": 56.0, "output_kw_max": 28.0, "final_year_of_manufacture": 2011, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015245", "000005", "0", "2013/May/07 10:33", "Baxi Heating", "Main", "System", "28 HE", "GC No. 41-467-03", "2006", "2011", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "28.0", "28.0", "", "", "85.7", "76.7", "", "56.0", "", "2", "", "", "102", "1", "2", "180", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.4", "91.3", "", "", "", "", "90.5"]} +{"pcdb_id": 15247, "brand_name": "Pro", "model_name": "Pro-Combi", "model_qualifier": "85HE", "winter_efficiency_pct": 85.4, "summer_efficiency_pct": 76.8, "comparative_hot_water_efficiency_pct": 54.0, "output_kw_max": 24.35, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015247", "000247", "0", "2007/Jan/30 09:11", "F & P Wholesale", "Pro", "Pro-Combi", "85HE", "4709482", "2006", "current", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "24.35", "24.35", "", "", "85.4", "76.8", "", "54.0", "", "2", "", "", "104", "1", "2", "153", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.4", "90.6", "", "", "", "", "90.0"]} +{"pcdb_id": 15250, "brand_name": "Pro", "model_name": "Pro-Combi", "model_qualifier": "100HE", "winter_efficiency_pct": 85.6, "summer_efficiency_pct": 77.0, "comparative_hot_water_efficiency_pct": 54.1, "output_kw_max": 28.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015250", "000247", "0", "2007/Jan/30 09:11", "F & P Wholesale", "Pro", "Pro-Combi", "100HE", "4709481", "2006", "current", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "28.30", "28.30", "", "", "85.6", "77.0", "", "54.1", "", "2", "", "", "104", "1", "2", "153", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.4", "90.9", "", "", "", "", "90.2"]} +{"pcdb_id": 15253, "brand_name": "Ferroli", "model_name": "Optimax", "model_qualifier": "HE 31 S", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 30.2, "final_year_of_manufacture": 2008, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015253", "000097", "0", "2012/Mar/27 10:12", "Ferroli SpA", "Ferroli", "Optimax", "HE 31 S", "", "2007", "2008", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "30.2", "30.2", "", "", "88.7", "79.7", "", "58.2", "", "2", "", "", "102", "1", "2", "130", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.7", "98.3", "", "", "", "", "96.5"]} +{"pcdb_id": 15260, "brand_name": "Keston", "model_name": "Qudos", "model_qualifier": "28h", "winter_efficiency_pct": 89.6, "summer_efficiency_pct": 80.6, "comparative_hot_water_efficiency_pct": 58.9, "output_kw_max": 28.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015260", "000022", "0", "2012/Mar/27 10:12", "Keston Boilers", "Keston", "Qudos", "28h", "", "2007", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "28.4", "28.4", "", "", "89.6", "80.6", "", "58.9", "", "2", "", "", "102", "1", "2", "8.5", "84", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.7", "100.1", "", "", "", "", "98.1"]} +{"pcdb_id": 15261, "brand_name": "Keston", "model_name": "Qudos", "model_qualifier": "28hp", "winter_efficiency_pct": 89.8, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 59.0, "output_kw_max": 28.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015261", "000022", "0", "2012/Mar/27 10:12", "Keston Boilers", "Keston", "Qudos", "28hp", "", "2007", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "28.4", "28.4", "", "", "89.8", "80.8", "", "59.0", "", "2", "1", "", "102", "1", "2", "8.5", "84", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "91.7", "100.1", "", "", "", "", "98.5"]} +{"pcdb_id": 15262, "brand_name": "Keston", "model_name": "Qudos", "model_qualifier": "28s", "winter_efficiency_pct": 89.6, "summer_efficiency_pct": 80.6, "comparative_hot_water_efficiency_pct": 58.9, "output_kw_max": 28.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015262", "000022", "0", "2012/Mar/27 10:12", "Keston Boilers", "Keston", "Qudos", "28s", "", "2007", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "28.4", "28.4", "", "", "89.6", "80.6", "", "58.9", "", "2", "", "", "102", "1", "2", "150", "8.5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.7", "100.1", "", "", "", "", "98.1"]} +{"pcdb_id": 15263, "brand_name": "Keston", "model_name": "Qudos", "model_qualifier": "28sp", "winter_efficiency_pct": 89.8, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 59.0, "output_kw_max": 28.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015263", "000022", "0", "2012/Mar/27 10:12", "Keston Boilers", "Keston", "Qudos", "28sp", "", "2007", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "28.4", "28.4", "", "", "89.8", "80.8", "", "59.0", "", "2", "1", "", "102", "1", "2", "150", "8.5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "91.7", "100.1", "", "", "", "", "98.5"]} +{"pcdb_id": 15264, "brand_name": "Sime", "model_name": "Format", "model_qualifier": "100 B", "winter_efficiency_pct": 83.1, "summer_efficiency_pct": 73.0, "comparative_hot_water_efficiency_pct": 51.3, "output_kw_max": 30.8, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015264", "000213", "0", "2018/Feb/26 16:55", "Fonderie Sime S.p.A.", "Sime", "Format", "100 B", "", "2007", "2018", "2", "2", "1", "2", "0", "", "", "1", "3", "2", "30.8", "30.8", "", "", "83.1", "73.0", "", "51.3", "", "2", "1", "", "104", "1", "2", "165", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "87.1", "86.5", "", "", "", "", "86.6"]} +{"pcdb_id": 15265, "brand_name": "Sime", "model_name": "Format", "model_qualifier": "100 B", "winter_efficiency_pct": 82.5, "summer_efficiency_pct": 72.4, "comparative_hot_water_efficiency_pct": 50.9, "output_kw_max": 30.8, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015265", "000213", "0", "2018/Feb/26 16:54", "Fonderie Sime S.p.A.", "Sime", "Format", "100 B", "", "2007", "2018", "1", "2", "1", "2", "0", "", "", "1", "3", "2", "30.8", "30.8", "", "", "82.5", "72.4", "", "50.9", "", "2", "", "", "104", "1", "2", "165", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "85.2", "84.6", "", "", "", "", "84.7"]} +{"pcdb_id": 15266, "brand_name": "Sime", "model_name": "Format", "model_qualifier": "80 B", "winter_efficiency_pct": 83.1, "summer_efficiency_pct": 73.0, "comparative_hot_water_efficiency_pct": 51.3, "output_kw_max": 23.8, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015266", "000213", "0", "2018/Feb/26 16:56", "Fonderie Sime S.p.A.", "Sime", "Format", "80 B", "", "2007", "2018", "2", "2", "1", "2", "0", "", "", "1", "3", "2", "23.8", "23.8", "", "", "83.1", "73.0", "", "51.3", "", "2", "1", "", "104", "1", "2", "120", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "87.2", "86.9", "", "", "", "", "87.0"]} +{"pcdb_id": 15267, "brand_name": "Sime", "model_name": "Format", "model_qualifier": "80 B", "winter_efficiency_pct": 82.8, "summer_efficiency_pct": 72.7, "comparative_hot_water_efficiency_pct": 51.1, "output_kw_max": 23.8, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015267", "000213", "0", "2018/Feb/26 16:56", "Fonderie Sime S.p.A.", "Sime", "Format", "80 B", "", "2007", "2018", "1", "2", "1", "2", "0", "", "", "1", "3", "2", "23.8", "23.8", "", "", "82.8", "72.7", "", "51.1", "", "2", "", "", "104", "1", "2", "120", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "85.3", "85.1", "", "", "", "", "85.1"]} +{"pcdb_id": 15268, "brand_name": "Alpha", "model_name": "CD 35 C", "model_qualifier": "", "winter_efficiency_pct": 89.7, "summer_efficiency_pct": 81.1, "comparative_hot_water_efficiency_pct": 57.0, "output_kw_max": 28.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015268", "000001", "0", "2007/May/24 10:22", "Alpha Therm", "Alpha", "CD 35 C", "", "", "2007", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "28", "28", "", "", "89.7", "81.1", "", "57.0", "", "2", "1", "", "104", "1", "2", "125", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.7", "100.3", "", "", "", "", "98.5"]} +{"pcdb_id": 15269, "brand_name": "Alpha", "model_name": "CD 35 C", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 56.3, "output_kw_max": 28.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015269", "000001", "0", "2010/Sep/29 11:39", "Alpha Therm", "Alpha", "CD 35 C", "", "", "2007", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28", "28", "", "", "88.6", "80.0", "", "56.3", "", "2", "", "", "104", "1", "2", "125", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.7", "98.1", "", "", "", "", "96.3"]} +{"pcdb_id": 15270, "brand_name": "Alpha", "model_name": "CD 28 C", "model_qualifier": "", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 56.6, "output_kw_max": 24.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015270", "000001", "0", "2007/May/24 10:22", "Alpha Therm", "Alpha", "CD 28 C", "", "", "2007", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "89.1", "80.5", "", "56.6", "", "2", "1", "", "104", "1", "2", "125", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.3", "99.1", "", "", "", "", "97.4"]} +{"pcdb_id": 15271, "brand_name": "Alpha", "model_name": "CD 28 C", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 55.9, "output_kw_max": 24.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015271", "000001", "0", "2010/Sep/29 11:39", "Alpha Therm", "Alpha", "CD 28 C", "", "", "2007", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "88.1", "79.5", "", "55.9", "", "2", "", "", "104", "1", "2", "125", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "96.9", "", "", "", "", "95.3"]} +{"pcdb_id": 15272, "brand_name": "Alpha", "model_name": "CD 25 C", "model_qualifier": "", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 56.8, "output_kw_max": 18.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015272", "000001", "0", "2007/May/24 10:22", "Alpha Therm", "Alpha", "CD 25 C", "", "", "2007", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "18", "18", "", "", "89.4", "80.8", "", "56.8", "", "2", "1", "", "104", "1", "2", "125", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.2", "99.9", "", "", "", "", "98.1"]} +{"pcdb_id": 15273, "brand_name": "Alpha", "model_name": "CD 25 C", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 56.1, "output_kw_max": 18.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015273", "000001", "0", "2010/Sep/29 11:40", "Alpha Therm", "Alpha", "CD 25 C", "", "", "2007", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "18", "18", "", "", "88.4", "79.8", "", "56.1", "", "2", "", "", "104", "1", "2", "125", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.2", "97.8", "", "", "", "", "95.9"]} +{"pcdb_id": 15274, "brand_name": "Heatline", "model_name": "Vizo 24", "model_qualifier": "", "winter_efficiency_pct": 84.9, "summer_efficiency_pct": 76.3, "comparative_hot_water_efficiency_pct": 53.6, "output_kw_max": 24.82, "final_year_of_manufacture": 2009, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015274", "000215", "0", "2011/Aug/31 10:43", "Turk Demir Dokum Fab AS", "Heatline", "Vizo 24", "", "", "2006", "2009", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.82", "24.82", "", "", "84.9", "76.3", "", "53.6", "", "2", "", "", "104", "1", "2", "196", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.0", "89.3", "", "", "", "", "88.9"]} +{"pcdb_id": 15275, "brand_name": "Heatline", "model_name": "Vizo 28", "model_qualifier": "", "winter_efficiency_pct": 85.5, "summer_efficiency_pct": 76.9, "comparative_hot_water_efficiency_pct": 54.1, "output_kw_max": 27.47, "final_year_of_manufacture": 2011, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015275", "000215", "0", "2011/Aug/31 10:40", "Turk Demir Dokum Fab AS", "Heatline", "Vizo 28", "", "", "2006", "2011", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "27.47", "27.47", "", "", "85.5", "76.9", "", "54.1", "", "2", "", "", "104", "1", "2", "196", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "86.9", "91.0", "", "", "", "", "90.2"]} +{"pcdb_id": 15276, "brand_name": "Heatline", "model_name": "Solaris", "model_qualifier": "24 pcs", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 24.42, "final_year_of_manufacture": 2009, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015276", "000215", "0", "2012/Mar/27 10:12", "Turk Demir Dokum Fab AS", "Heatline", "Solaris", "24 pcs", "", "2004", "2009", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24.42", "24.42", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "140", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "96.8", "", "", "", "", "95.1"]} +{"pcdb_id": 15277, "brand_name": "ATAG", "model_name": "E32C", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 56.4, "output_kw_max": 28.2, "final_year_of_manufacture": 2014, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015277", "000227", "0", "2018/Apr/25 14:46", "ATAG Verwarming Nederland BV", "ATAG", "E32C", "", "", "2007", "2014", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "28.2", "28.2", "", "", "88.8", "80.2", "", "56.4", "", "2", "", "", "104", "1", "2", "145", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "98.8", "", "", "", "", "96.8"]} +{"pcdb_id": 15278, "brand_name": "ATAG", "model_name": "E22S", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 19.3, "final_year_of_manufacture": 2014, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015278", "000227", "0", "2013/Oct/23 12:57", "ATAG Verwarming Nederland BV", "ATAG", "E22S", "", "", "2007", "2014", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "19.3", "19.3", "", "", "88.8", "79.8", "", "58.3", "", "2", "", "", "102", "1", "2", "122", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "98.9", "", "", "", "", "96.8"]} +{"pcdb_id": 15279, "brand_name": "ATAG", "model_name": "E22C", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 56.4, "output_kw_max": 19.3, "final_year_of_manufacture": 2014, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015279", "000227", "0", "2013/Oct/23 12:57", "ATAG Verwarming Nederland BV", "ATAG", "E22C", "", "", "2007", "2014", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "19.3", "19.3", "", "", "88.8", "80.2", "", "56.4", "", "2", "", "", "104", "1", "2", "122", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "98.9", "", "", "", "", "96.8"]} +{"pcdb_id": 15280, "brand_name": "ATAG", "model_name": "E32S", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 28.2, "final_year_of_manufacture": 2014, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015280", "000227", "0", "2013/Oct/23 12:58", "ATAG Verwarming Nederland BV", "ATAG", "E32S", "", "", "2007", "2014", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "28.2", "28.2", "", "", "88.8", "79.8", "", "58.3", "", "2", "", "", "102", "1", "2", "145", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "98.8", "", "", "", "", "96.8"]} +{"pcdb_id": 15281, "brand_name": "Worcester", "model_name": "Greenstar CDi", "model_qualifier": "27 CDi", "winter_efficiency_pct": 89.8, "summer_efficiency_pct": 81.2, "comparative_hot_water_efficiency_pct": 57.1, "output_kw_max": 26.2, "final_year_of_manufacture": 2012, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015281", "000035", "0", "2020/Sep/08 09:51", "Worcester Bosch Group", "Worcester", "Greenstar CDi", "27 CDi", "47-406-13", "2007", "2012", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "26.2", "26.2", "", "", "89.8", "81.2", "", "57.1", "", "2", "1", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0305", "", "", "", "", "", "", "", "", "90.1", "101.0", "", "", "", "", "99.0"]} +{"pcdb_id": 15282, "brand_name": "Worcester", "model_name": "Greenstar CDi", "model_qualifier": "27 CDi", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 56.4, "output_kw_max": 26.2, "final_year_of_manufacture": 2012, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015282", "000035", "0", "2020/Sep/08 09:51", "Worcester Bosch Group", "Worcester", "Greenstar CDi", "27 CDi", "47-406-12", "2007", "2012", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "26.2", "26.2", "", "", "88.8", "80.2", "", "56.4", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0305", "", "", "", "", "", "", "", "", "88.1", "98.8", "", "", "", "", "96.8"]} +{"pcdb_id": 15283, "brand_name": "Worcester", "model_name": "Greenstar CDi", "model_qualifier": "31 CDi", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 56.4, "output_kw_max": 30.0, "final_year_of_manufacture": 2012, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015283", "000035", "0", "2020/Sep/08 09:52", "Worcester Bosch Group", "Worcester", "Greenstar CDi", "31 CDi", "47-406-14", "2007", "2012", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "30", "30", "", "", "88.8", "80.2", "", "56.4", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0305", "", "", "", "", "", "", "", "", "88.1", "98.8", "", "", "", "", "96.8"]} +{"pcdb_id": 15284, "brand_name": "Worcester", "model_name": "Greenstar CDi", "model_qualifier": "31 CDi", "winter_efficiency_pct": 89.8, "summer_efficiency_pct": 81.2, "comparative_hot_water_efficiency_pct": 57.1, "output_kw_max": 30.0, "final_year_of_manufacture": 2012, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015284", "000035", "0", "2020/Sep/08 09:52", "Worcester Bosch Group", "Worcester", "Greenstar CDi", "31 CDi", "47-406-15", "2007", "2012", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "30", "30", "", "", "89.8", "81.2", "", "57.1", "", "2", "1", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0305", "", "", "", "", "", "", "", "", "90.1", "101.0", "", "", "", "", "99.0"]} +{"pcdb_id": 15285, "brand_name": "Baxi", "model_name": "Platinum Combi", "model_qualifier": "40 HE", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 55.8, "output_kw_max": 32.0, "final_year_of_manufacture": 2008, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015285", "000005", "0", "2010/Nov/19 09:04", "Baxi Heating", "Baxi", "Platinum Combi", "40 HE", "GC No. 47-075-30", "2007", "2008", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "32", "32", "", "", "87.9", "79.3", "", "55.8", "", "2", "", "", "104", "1", "2", "155", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "96.7", "", "", "", "", "95.0"]} +{"pcdb_id": 15286, "brand_name": "Baxi", "model_name": "Platinum Combi", "model_qualifier": "33 HE", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 55.8, "output_kw_max": 28.0, "final_year_of_manufacture": 2008, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015286", "000005", "0", "2010/Nov/19 09:04", "Baxi Heating", "Baxi", "Platinum Combi", "33 HE", "GC No. 47-075-29", "2007", "2008", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28", "28", "", "", "87.9", "79.3", "", "55.8", "", "2", "", "", "104", "1", "2", "160", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "96.7", "", "", "", "", "95.0"]} +{"pcdb_id": 15287, "brand_name": "Baxi", "model_name": "Platinum Combi", "model_qualifier": "28 HE", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 55.8, "output_kw_max": 24.0, "final_year_of_manufacture": 2008, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015287", "000005", "0", "2010/Nov/19 09:04", "Baxi Heating", "Baxi", "Platinum Combi", "28 HE", "GC No. 47-075-28", "2007", "2008", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "88.0", "79.4", "", "55.8", "", "2", "", "", "104", "1", "2", "155", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "96.9", "", "", "", "", "95.2"]} +{"pcdb_id": 15288, "brand_name": "Baxi", "model_name": "Platinum Combi", "model_qualifier": "24 HE", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 55.8, "output_kw_max": 24.0, "final_year_of_manufacture": 2008, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015288", "000005", "0", "2013/May/07 10:33", "Baxi Heating", "Baxi", "Platinum Combi", "24 HE", "GC No. 47-075-27", "2007", "2008", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "88.0", "79.4", "", "55.8", "", "2", "", "", "104", "1", "2", "155", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "96.9", "", "", "", "", "95.2"]} +{"pcdb_id": 15289, "brand_name": "Potterton", "model_name": "Promax Combi", "model_qualifier": "24 HE Plus", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 55.8, "output_kw_max": 20.0, "final_year_of_manufacture": 2008, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015289", "000005", "0", "2010/Nov/19 09:19", "Baxi Heating", "Potterton", "Promax Combi", "24 HE Plus", "GC No. 47-393-17", "2007", "2008", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "20", "20", "", "", "88.0", "79.4", "", "55.8", "", "2", "", "", "104", "1", "2", "155", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "96.9", "", "", "", "", "95.2"]} +{"pcdb_id": 15290, "brand_name": "Baxi", "model_name": "Duo-tec Combi", "model_qualifier": "40 HE", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 55.8, "output_kw_max": 32.0, "final_year_of_manufacture": 2008, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015290", "000005", "0", "2010/Nov/19 09:05", "Baxi Heating", "Baxi", "Duo-tec Combi", "40 HE", "GC No. 47-075-26", "2007", "2008", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "32", "32", "", "", "87.9", "79.3", "", "55.8", "", "2", "", "", "104", "1", "2", "155", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "96.7", "", "", "", "", "95.0"]} +{"pcdb_id": 15291, "brand_name": "Baxi", "model_name": "Megaflo System", "model_qualifier": "15 HE", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 15.0, "final_year_of_manufacture": 2008, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015291", "000005", "0", "2012/Mar/27 10:12", "Baxi Heating", "Baxi", "Megaflo System", "15 HE", "GC No. 41-075-52", "2007", "2008", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "15", "15", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "130", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "96.8", "", "", "", "", "95.1"]} +{"pcdb_id": 15292, "brand_name": "Baxi", "model_name": "Megaflo System", "model_qualifier": "18 HE", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 18.0, "final_year_of_manufacture": 2008, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015292", "000005", "0", "2012/Mar/27 10:12", "Baxi Heating", "Baxi", "Megaflo System", "18 HE", "GC No. 41-075-53", "2007", "2008", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18", "18", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "140", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "96.9", "", "", "", "", "95.2"]} +{"pcdb_id": 15293, "brand_name": "Baxi", "model_name": "Megaflo System", "model_qualifier": "32 HE", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 78.9, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 32.0, "final_year_of_manufacture": 2008, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015293", "000005", "0", "2012/Mar/27 10:12", "Baxi Heating", "Baxi", "Megaflo System", "32 HE", "GC No. 41-075-54", "2007", "2008", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "32", "32", "", "", "87.9", "78.9", "", "57.7", "", "2", "", "", "102", "1", "2", "160", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "96.7", "", "", "", "", "95.0"]} +{"pcdb_id": 15294, "brand_name": "E.C.A.", "model_name": "Confeo Premix", "model_qualifier": "CP 24 HCH", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 24.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015294", "000248", "0", "2012/Mar/27 10:12", "Emas Makina Sanayi AS", "E.C.A.", "Confeo Premix", "CP 24 HCH", "", "2006", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "24", "24", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "115", "4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "96.9", "", "", "", "", "95.2"]} +{"pcdb_id": 15299, "brand_name": "E.C.A.", "model_name": "Confeo Premix", "model_qualifier": "CP 24 HM", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 86.6, "comparative_hot_water_efficiency_pct": 71.8, "output_kw_max": 22.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0144, "loss_factor_f1_kwh_per_day": 1.127, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015299", "000248", "0", "2012/Jun/28 15:41", "Emas Makina Sanayi AS", "E.C.A.", "Confeo Premix", "CP 24 HM", "", "2006", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "22.2", "22.2", "", "", "88.0", "86.6", "", "71.8", "", "2", "", "", "104", "1", "2", "127", "5", "0", "", "", "0", "0", "", "", "", "", "1", "7.3381", "0.2007", "0.0144", "1.127", "", "", "", "", "", "1", "1", "0", "0005", "", "", "", "", "", "", "", "", "87.8", "96.9", "", "", "", "", "95.2"]} +{"pcdb_id": 15300, "brand_name": "E.C.A.", "model_name": "Confeo Premix", "model_qualifier": "CP 24 HCH", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 24.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015300", "000248", "0", "2012/Mar/27 10:12", "Emas Makina Sanayi AS", "E.C.A.", "Confeo Premix", "CP 24 HCH", "", "2006", "current", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "24", "24", "", "", "89.0", "80.0", "", "58.5", "", "2", "1", "", "102", "1", "2", "115", "4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.8", "99.1", "", "", "", "", "97.3"]} +{"pcdb_id": 15301, "brand_name": "E.C.A.", "model_name": "Confeo Premix", "model_qualifier": "CP 24 HM", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.4, "comparative_hot_water_efficiency_pct": 62.8, "output_kw_max": 22.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015301", "000248", "0", "2013/Apr/08 09:34", "Emas Makina Sanayi AS", "E.C.A.", "Confeo Premix", "CP 24 HM", "", "2006", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "22.2", "22.2", "", "", "89.0", "80.4", "", "62.8", "", "2", "1", "", "104", "1", "2", "127", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "0", "0005", "", "", "", "", "", "", "", "", "89.8", "99.1", "", "", "", "", "97.3"]} +{"pcdb_id": 15302, "brand_name": "E.C.A.", "model_name": "Confeo Premix", "model_qualifier": "CP 24 HST", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 24.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015302", "000248", "0", "2012/Mar/27 10:12", "Emas Makina Sanayi AS", "E.C.A.", "Confeo Premix", "CP 24 HST", "", "2006", "current", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "24", "24", "", "", "89.0", "80.0", "", "58.5", "", "2", "1", "", "102", "1", "2", "115", "4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.8", "99.1", "", "", "", "", "97.3"]} +{"pcdb_id": 15303, "brand_name": "E.C.A.", "model_name": "Confeo Premix", "model_qualifier": "CP 24 HST", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 24.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015303", "000248", "0", "2012/Mar/27 10:12", "Emas Makina Sanayi AS", "E.C.A.", "Confeo Premix", "CP 24 HST", "", "2006", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "24", "24", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "115", "4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "96.9", "", "", "", "", "95.2"]} +{"pcdb_id": 15304, "brand_name": "E.C.A.", "model_name": "Confeo Premix", "model_qualifier": "CP 30 HCH", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 30.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015304", "000248", "0", "2012/Mar/27 10:12", "Emas Makina Sanayi AS", "E.C.A.", "Confeo Premix", "CP 30 HCH", "", "2006", "current", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "30", "30", "", "", "89.2", "80.2", "", "58.6", "", "2", "1", "", "102", "1", "2", "115", "4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.9", "99.6", "", "", "", "", "97.7"]} +{"pcdb_id": 15305, "brand_name": "E.C.A.", "model_name": "Confeo Premix", "model_qualifier": "CP 30 HCH", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 30.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015305", "000248", "0", "2012/Mar/27 10:12", "Emas Makina Sanayi AS", "E.C.A.", "Confeo Premix", "CP 30 HCH", "", "2006", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "30", "30", "", "", "88.2", "79.2", "", "57.9", "", "2", "", "", "102", "1", "2", "115", "4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "97.4", "", "", "", "", "95.6"]} +{"pcdb_id": 15306, "brand_name": "E.C.A.", "model_name": "Confeo Premix", "model_qualifier": "CP 30 HM", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 80.6, "comparative_hot_water_efficiency_pct": 62.9, "output_kw_max": 27.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015306", "000248", "0", "2013/Apr/08 09:34", "Emas Makina Sanayi AS", "E.C.A.", "Confeo Premix", "CP 30 HM", "", "2006", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "27.3", "27.3", "", "", "89.2", "80.6", "", "62.9", "", "2", "1", "", "104", "1", "2", "134", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "0", "0005", "", "", "", "", "", "", "", "", "89.9", "99.6", "", "", "", "", "97.7"]} +{"pcdb_id": 15307, "brand_name": "E.C.A.", "model_name": "Confeo Premix", "model_qualifier": "CP 30 HM", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 86.7, "comparative_hot_water_efficiency_pct": 70.5, "output_kw_max": 27.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.008, "loss_factor_f1_kwh_per_day": 1.29223, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015307", "000248", "0", "2012/Jun/28 15:44", "Emas Makina Sanayi AS", "E.C.A.", "Confeo Premix", "CP 30 HM", "", "2006", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "27.3", "27.3", "", "", "88.2", "86.7", "", "70.5", "", "2", "", "", "104", "1", "2", "134", "5", "0", "", "", "0", "0", "", "", "", "", "1", "7.4688", "0.225", "0.008", "1.29223", "", "", "", "", "", "1", "1", "0", "0005", "", "", "", "", "", "", "", "", "87.9", "97.4", "", "", "", "", "95.6"]} +{"pcdb_id": 15308, "brand_name": "E.C.A.", "model_name": "Confeo Premix", "model_qualifier": "CP 30 HST", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 30.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015308", "000248", "0", "2012/Mar/27 10:12", "Emas Makina Sanayi AS", "E.C.A.", "Confeo Premix", "CP 30 HST", "", "2006", "current", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "30", "30", "", "", "89.2", "80.2", "", "58.6", "", "2", "1", "", "102", "1", "2", "115", "4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.9", "99.6", "", "", "", "", "97.7"]} +{"pcdb_id": 15309, "brand_name": "E.C.A.", "model_name": "Confeo Premix", "model_qualifier": "CP 30 HST", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 30.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015309", "000248", "0", "2012/Mar/27 10:12", "Emas Makina Sanayi AS", "E.C.A.", "Confeo Premix", "CP 30 HST", "", "2006", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "30", "30", "", "", "88.2", "79.2", "", "57.9", "", "2", "", "", "102", "1", "2", "115", "4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "97.4", "", "", "", "", "95.6"]} +{"pcdb_id": 15310, "brand_name": "Mistral", "model_name": "CC 15/26 Plus Contract", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 81.9, "comparative_hot_water_efficiency_pct": 50.3, "output_kw_max": 26.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015310", "000056", "0", "2024/Jan/31 10:17", "Mistral Boilers", "Mistral", "CC 15/26 Plus Contract", "", "", "2007", "current", "4", "1", "1", "2", "0", "", "", "2", "3", "2", "15", "26.4", "", "", "88.0", "81.9", "", "50.3", "", "2", "", "", "203", "1", "1", "230", "0", "2", "1", "0", "35", "0", "25", "3", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.8", "94.8", "", "", "", "", "94.1"]} +{"pcdb_id": 15312, "brand_name": "Mistral", "model_name": "CC1 15/20 Std", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 81.9, "comparative_hot_water_efficiency_pct": 50.3, "output_kw_max": 20.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015312", "000056", "0", "2024/Jan/31 10:17", "Mistral Boilers", "Mistral", "CC1 15/20 Std", "", "", "2007", "current", "4", "1", "1", "2", "0", "", "", "2", "3", "2", "15", "20.5", "", "", "88.0", "81.9", "", "50.3", "", "2", "", "", "203", "1", "1", "230", "0", "2", "", "0", "35", "0", "25", "3", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.8", "94.8", "", "", "", "", "94.1"]} +{"pcdb_id": 15313, "brand_name": "Mistral", "model_name": "CC2 20/26 Std", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 81.9, "comparative_hot_water_efficiency_pct": 50.3, "output_kw_max": 26.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015313", "000056", "0", "2024/Jan/31 10:17", "Mistral Boilers", "Mistral", "CC2 20/26 Std", "", "", "2007", "current", "4", "1", "1", "2", "0", "", "", "2", "3", "2", "20.5", "26.4", "", "", "88.0", "81.9", "", "50.3", "", "2", "", "", "203", "1", "1", "230", "0", "2", "", "0", "35", "0", "25", "3", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.8", "94.8", "", "", "", "", "94.1"]} +{"pcdb_id": 15314, "brand_name": "Mistral", "model_name": "CC 15/26 Std Contract", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 81.9, "comparative_hot_water_efficiency_pct": 50.3, "output_kw_max": 26.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015314", "000056", "0", "2024/Jan/31 10:17", "Mistral Boilers", "Mistral", "CC 15/26 Std Contract", "", "", "2007", "current", "4", "1", "1", "2", "0", "", "", "2", "3", "2", "15", "26.4", "", "", "88.0", "81.9", "", "50.3", "", "2", "", "", "203", "1", "1", "230", "0", "2", "", "0", "35", "0", "25", "3", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.8", "94.8", "", "", "", "", "94.1"]} +{"pcdb_id": 15315, "brand_name": "Mistral", "model_name": "CBH1 15/20", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 20.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015315", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "CBH1 15/20", "", "", "2007", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "15", "20.5", "", "", "88.0", "80.2", "", "58.6", "", "2", "", "", "201", "1", "1", "230", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.8", "94.8", "", "", "", "", "94.1"]} +{"pcdb_id": 15317, "brand_name": "Mistral", "model_name": "CBH2 20/26", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 26.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015317", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "CBH2 20/26", "", "", "2007", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "20.5", "26.4", "", "", "88.0", "80.2", "", "58.6", "", "2", "", "", "201", "1", "1", "230", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.8", "94.8", "", "", "", "", "94.1"]} +{"pcdb_id": 15318, "brand_name": "Mistral", "model_name": "CBH 15/26 Contract", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 26.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015318", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "CBH 15/26 Contract", "", "", "2007", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "15", "26.4", "", "", "88.0", "80.2", "", "58.6", "", "2", "", "", "201", "1", "1", "230", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.8", "94.8", "", "", "", "", "94.1"]} +{"pcdb_id": 15319, "brand_name": "Mistral", "model_name": "CC1 15/20 Plus", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 81.9, "comparative_hot_water_efficiency_pct": 50.3, "output_kw_max": 20.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015319", "000056", "0", "2024/Jan/31 10:17", "Mistral Boilers", "Mistral", "CC1 15/20 Plus", "", "", "2007", "current", "4", "1", "1", "2", "0", "", "", "2", "3", "2", "15", "20.5", "", "", "88.0", "81.9", "", "50.3", "", "2", "", "", "203", "1", "1", "230", "0", "2", "", "0", "35", "0", "25", "3", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.8", "94.8", "", "", "", "", "94.1"]} +{"pcdb_id": 15320, "brand_name": "Mistral", "model_name": "CC2 20/26 Plus", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 81.9, "comparative_hot_water_efficiency_pct": 50.3, "output_kw_max": 26.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015320", "000056", "0", "2024/Jan/31 10:17", "Mistral Boilers", "Mistral", "CC2 20/26 Plus", "", "", "2007", "current", "4", "1", "1", "2", "0", "", "", "2", "3", "2", "20.5", "26.4", "", "", "88.0", "81.9", "", "50.3", "", "2", "", "", "203", "1", "1", "230", "0", "2", "", "0", "35", "0", "25", "3", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.8", "94.8", "", "", "", "", "94.1"]} +{"pcdb_id": 15321, "brand_name": "Mistral", "model_name": "CKUT 15/26 Contract", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 26.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015321", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "CKUT 15/26 Contract", "", "", "2007", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "15", "26.4", "", "", "88.0", "80.2", "", "58.6", "", "2", "", "", "201", "1", "1", "230", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.8", "94.8", "", "", "", "", "94.1"]} +{"pcdb_id": 15322, "brand_name": "Mistral", "model_name": "CKUT2 20/26", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 26.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015322", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "CKUT2 20/26", "", "", "2007", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "20.5", "26.4", "", "", "88.0", "80.2", "", "58.6", "", "2", "", "", "201", "1", "1", "230", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.8", "94.8", "", "", "", "", "94.1"]} +{"pcdb_id": 15323, "brand_name": "Mistral", "model_name": "CKUT1 15/20", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 20.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015323", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "CKUT1 15/20", "", "", "2007", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "15", "20.5", "", "", "88.0", "80.2", "", "58.6", "", "2", "", "", "201", "1", "1", "230", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.8", "94.8", "", "", "", "", "94.1"]} +{"pcdb_id": 15324, "brand_name": "Mistral", "model_name": "COD 15/26 Contract", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 26.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015324", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "COD 15/26 Contract", "", "", "2007", "current", "4", "1", "2", "1", "0", "", "", "2", "3", "2", "15", "26.4", "", "", "88.0", "80.2", "", "58.6", "", "2", "", "", "201", "1", "1", "230", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.8", "94.8", "", "", "", "", "94.1"]} +{"pcdb_id": 15325, "brand_name": "Mistral", "model_name": "COD2 20/26", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 26.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015325", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "COD2 20/26", "", "", "2007", "current", "4", "1", "2", "1", "0", "", "", "2", "3", "2", "20.5", "26.4", "", "", "88.0", "80.2", "", "58.6", "", "2", "", "", "201", "1", "1", "230", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.8", "94.8", "", "", "", "", "94.1"]} +{"pcdb_id": 15326, "brand_name": "Mistral", "model_name": "COD1 15/20", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 20.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015326", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "COD1 15/20", "", "", "2007", "current", "4", "1", "2", "1", "0", "", "", "2", "3", "2", "15", "20.5", "", "", "88.0", "80.2", "", "58.6", "", "2", "", "", "201", "1", "1", "230", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.8", "94.8", "", "", "", "", "94.1"]} +{"pcdb_id": 15327, "brand_name": "Mistral", "model_name": "COD1 SS 15/20", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 20.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015327", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "COD1 SS 15/20", "", "", "2007", "current", "4", "1", "2", "1", "0", "", "", "2", "3", "2", "15", "20.5", "", "", "88.0", "80.2", "", "58.6", "", "2", "", "", "201", "1", "1", "230", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.8", "94.8", "", "", "", "", "94.1"]} +{"pcdb_id": 15328, "brand_name": "Mistral", "model_name": "COD2 SS 20/26", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 26.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015328", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "COD2 SS 20/26", "", "", "2007", "current", "4", "1", "2", "1", "0", "", "", "2", "3", "2", "20.5", "26.4", "", "", "88.0", "80.2", "", "58.6", "", "2", "", "", "201", "1", "1", "230", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.8", "94.8", "", "", "", "", "94.1"]} +{"pcdb_id": 15329, "brand_name": "Mistral", "model_name": "COD SS 15/26 Contract", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 26.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015329", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "COD SS 15/26 Contract", "", "", "2007", "current", "4", "1", "2", "1", "0", "", "", "2", "3", "2", "15.0", "26.4", "", "", "88.0", "80.2", "", "58.6", "", "2", "", "", "201", "1", "1", "230", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.8", "94.8", "", "", "", "", "94.1"]} +{"pcdb_id": 15330, "brand_name": "Mistral", "model_name": "CODC 15/26 Std Contract", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 81.9, "comparative_hot_water_efficiency_pct": 50.3, "output_kw_max": 26.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015330", "000056", "0", "2024/Jan/31 10:17", "Mistral Boilers", "Mistral", "CODC 15/26 Std Contract", "", "", "2007", "current", "4", "1", "2", "2", "0", "", "", "2", "3", "2", "15.0", "26.4", "", "", "88.0", "81.9", "", "50.3", "", "2", "", "", "203", "1", "1", "230", "0", "2", "", "0", "35", "0", "25", "3", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.8", "94.8", "", "", "", "", "94.1"]} +{"pcdb_id": 15332, "brand_name": "Mistral", "model_name": "CODC2 20/26 Std", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 81.9, "comparative_hot_water_efficiency_pct": 50.3, "output_kw_max": 26.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015332", "000056", "0", "2024/Jan/31 10:17", "Mistral Boilers", "Mistral", "CODC2 20/26 Std", "", "", "2007", "current", "4", "1", "2", "2", "0", "", "", "2", "3", "2", "20.0", "26.4", "", "", "88.0", "81.9", "", "50.3", "", "2", "", "", "203", "1", "1", "230", "0", "2", "", "0", "35", "0", "25", "3", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.8", "94.8", "", "", "", "", "94.1"]} +{"pcdb_id": 15333, "brand_name": "Mistral", "model_name": "CODC 15/26 Plus Contract", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 81.9, "comparative_hot_water_efficiency_pct": 50.3, "output_kw_max": 26.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015333", "000056", "0", "2024/Jan/31 10:17", "Mistral Boilers", "Mistral", "CODC 15/26 Plus Contract", "", "", "2007", "current", "4", "1", "2", "2", "0", "", "", "2", "3", "2", "15.0", "26.4", "", "", "88.0", "81.9", "", "50.3", "", "2", "", "", "203", "1", "1", "230", "0", "2", "", "0", "35", "0", "25", "3", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.8", "94.8", "", "", "", "", "94.1"]} +{"pcdb_id": 15334, "brand_name": "Mistral", "model_name": "CODC2 20/26 Plus", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 81.9, "comparative_hot_water_efficiency_pct": 50.3, "output_kw_max": 26.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015334", "000056", "0", "2024/Jan/31 10:17", "Mistral Boilers", "Mistral", "CODC2 20/26 Plus", "", "", "2007", "current", "4", "1", "2", "2", "0", "", "", "2", "3", "2", "20.0", "26.4", "", "", "88.0", "81.9", "", "50.3", "", "2", "", "", "203", "1", "1", "230", "0", "2", "", "0", "35", "0", "25", "3", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.8", "94.8", "", "", "", "", "94.1"]} +{"pcdb_id": 15335, "brand_name": "Mistral", "model_name": "CODC1 15/20 Plus", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 81.9, "comparative_hot_water_efficiency_pct": 50.3, "output_kw_max": 20.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015335", "000056", "0", "2024/Jan/31 10:17", "Mistral Boilers", "Mistral", "CODC1 15/20 Plus", "", "", "2007", "current", "4", "1", "2", "2", "0", "", "", "2", "3", "2", "15.0", "20.5", "", "", "88.0", "81.9", "", "50.3", "", "2", "", "", "203", "1", "1", "230", "0", "2", "", "0", "35", "0", "25", "3", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.8", "94.8", "", "", "", "", "94.1"]} +{"pcdb_id": 15336, "brand_name": "Mistral", "model_name": "CS 15/26 Contract", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 26.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015336", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "CS 15/26 Contract", "", "", "2007", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "15.0", "26.4", "", "", "88.0", "80.2", "", "58.6", "", "2", "", "", "201", "1", "1", "230", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.8", "94.8", "", "", "", "", "94.1"]} +{"pcdb_id": 15337, "brand_name": "Mistral", "model_name": "CS1 15/20", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 20.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015337", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "CS1 15/20", "", "", "2007", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "15.0", "20.5", "", "", "88.0", "80.2", "", "58.6", "", "2", "", "", "201", "1", "1", "230", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.8", "94.8", "", "", "", "", "94.1"]} +{"pcdb_id": 15338, "brand_name": "Mistral", "model_name": "CS2 20/26", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 26.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015338", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "CS2 20/26", "", "", "2007", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "20.5", "26.4", "", "", "88.0", "80.2", "", "58.6", "", "2", "", "", "201", "1", "1", "230", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.8", "94.8", "", "", "", "", "94.1"]} +{"pcdb_id": 15339, "brand_name": "Mistral", "model_name": "CBH 26/40 Contract", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 58.7, "output_kw_max": 40.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015339", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "CBH 26/40 Contract", "", "", "2007", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "26.4", "40", "", "", "88.1", "80.3", "", "58.7", "", "2", "", "", "201", "1", "1", "230", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.7", "95.2", "", "", "", "", "94.3"]} +{"pcdb_id": 15340, "brand_name": "Mistral", "model_name": "CBH4 35/40", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 58.7, "output_kw_max": 40.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015340", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "CBH4 35/40", "", "", "2007", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "35", "40", "", "", "88.1", "80.3", "", "58.7", "", "2", "", "", "201", "1", "1", "230", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.7", "95.2", "", "", "", "", "94.3"]} +{"pcdb_id": 15341, "brand_name": "Mistral", "model_name": "CBH3 26/35", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 58.7, "output_kw_max": 35.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015341", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "CBH3 26/35", "", "", "2007", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "26", "35", "", "", "88.1", "80.3", "", "58.7", "", "2", "", "", "201", "1", "1", "230", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.7", "95.2", "", "", "", "", "94.3"]} +{"pcdb_id": 15342, "brand_name": "Mistral", "model_name": "CODC3 26/35 Std", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 82.0, "comparative_hot_water_efficiency_pct": 50.4, "output_kw_max": 35.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015342", "000056", "0", "2024/Jan/31 10:17", "Mistral Boilers", "Mistral", "CODC3 26/35 Std", "", "", "2007", "current", "4", "1", "2", "2", "0", "", "", "2", "3", "2", "26", "35", "", "", "88.1", "82.0", "", "50.4", "", "2", "", "", "203", "1", "1", "230", "0", "2", "", "0", "35", "0", "25", "3", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.7", "95.2", "", "", "", "", "94.3"]} +{"pcdb_id": 15343, "brand_name": "Mistral", "model_name": "CODC4 35/40 Std", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 82.0, "comparative_hot_water_efficiency_pct": 50.4, "output_kw_max": 40.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015343", "000056", "0", "2024/Jan/31 10:17", "Mistral Boilers", "Mistral", "CODC4 35/40 Std", "", "", "2007", "current", "4", "1", "2", "2", "0", "", "", "2", "3", "2", "35", "40", "", "", "88.1", "82.0", "", "50.4", "", "2", "", "", "203", "1", "1", "230", "0", "2", "", "0", "35", "0", "25", "3", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.7", "95.2", "", "", "", "", "94.3"]} +{"pcdb_id": 15344, "brand_name": "Mistral", "model_name": "CODC 26/40 Std Contract", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 82.0, "comparative_hot_water_efficiency_pct": 50.4, "output_kw_max": 40.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015344", "000056", "0", "2024/Jan/31 10:17", "Mistral Boilers", "Mistral", "CODC 26/40 Std Contract", "", "", "2007", "current", "4", "1", "2", "2", "0", "", "", "2", "3", "2", "26.4", "40", "", "", "88.1", "82.0", "", "50.4", "", "2", "", "", "203", "1", "1", "230", "0", "2", "", "0", "35", "0", "25", "3", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.7", "95.2", "", "", "", "", "94.3"]} +{"pcdb_id": 15345, "brand_name": "Mistral", "model_name": "CC 26/40 Std Contract", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 82.0, "comparative_hot_water_efficiency_pct": 50.4, "output_kw_max": 40.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015345", "000056", "0", "2024/Jan/31 10:17", "Mistral Boilers", "Mistral", "CC 26/40 Std Contract", "", "", "2007", "current", "4", "1", "1", "2", "0", "", "", "2", "3", "2", "26", "40", "", "", "88.1", "82.0", "", "50.4", "", "2", "", "", "203", "1", "1", "230", "0", "2", "", "0", "35", "0", "25", "3", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.7", "95.2", "", "", "", "", "94.3"]} +{"pcdb_id": 15346, "brand_name": "Mistral", "model_name": "CC4 35/40 Std", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 82.0, "comparative_hot_water_efficiency_pct": 50.4, "output_kw_max": 40.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015346", "000056", "0", "2024/Jan/31 10:17", "Mistral Boilers", "Mistral", "CC4 35/40 Std", "", "", "2007", "current", "4", "1", "1", "2", "0", "", "", "2", "3", "2", "35", "40", "", "", "88.1", "82.0", "", "50.4", "", "2", "", "", "203", "1", "1", "230", "0", "2", "", "0", "35", "0", "25", "3", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.7", "95.2", "", "", "", "", "94.3"]} +{"pcdb_id": 15347, "brand_name": "Mistral", "model_name": "CC3 26/35 Std", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 82.0, "comparative_hot_water_efficiency_pct": 50.4, "output_kw_max": 35.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015347", "000056", "0", "2024/Jan/31 10:17", "Mistral Boilers", "Mistral", "CC3 26/35 Std", "", "", "2007", "current", "4", "1", "1", "2", "0", "", "", "2", "3", "2", "26", "35", "", "", "88.1", "82.0", "", "50.4", "", "2", "", "", "203", "1", "1", "230", "0", "2", "", "0", "35", "0", "25", "3", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.7", "95.2", "", "", "", "", "94.3"]} +{"pcdb_id": 15348, "brand_name": "Mistral", "model_name": "CKUT 26/40 Contract", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 58.7, "output_kw_max": 40.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015348", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "CKUT 26/40 Contract", "", "", "2007", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "26", "40", "", "", "88.1", "80.3", "", "58.7", "", "2", "", "", "201", "1", "1", "230", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.7", "95.2", "", "", "", "", "94.3"]} +{"pcdb_id": 15349, "brand_name": "Mistral", "model_name": "CKUT3 26/35", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 58.7, "output_kw_max": 35.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015349", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "CKUT3 26/35", "", "", "2007", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "26", "35", "", "", "88.1", "80.3", "", "58.7", "", "2", "", "", "201", "1", "1", "230", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.7", "95.2", "", "", "", "", "94.3"]} +{"pcdb_id": 15350, "brand_name": "Mistral", "model_name": "CKUT4 35/40", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 58.7, "output_kw_max": 40.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015350", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "CKUT4 35/40", "", "", "2007", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "35", "40", "", "", "88.1", "80.3", "", "58.7", "", "2", "", "", "201", "1", "1", "230", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.7", "95.2", "", "", "", "", "94.3"]} +{"pcdb_id": 15351, "brand_name": "Mistral", "model_name": "COD3 26/35", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 58.7, "output_kw_max": 35.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015351", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "COD3 26/35", "", "", "2007", "current", "4", "1", "2", "1", "0", "", "", "2", "3", "2", "26", "35", "", "", "88.1", "80.3", "", "58.7", "", "2", "", "", "201", "1", "1", "230", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.7", "95.2", "", "", "", "", "94.3"]} +{"pcdb_id": 15352, "brand_name": "Mistral", "model_name": "COD 26/40 Contract", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 58.7, "output_kw_max": 40.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015352", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "COD 26/40 Contract", "", "", "2007", "current", "4", "1", "2", "1", "0", "", "", "2", "3", "2", "26", "40", "", "", "88.1", "80.3", "", "58.7", "", "2", "", "", "201", "1", "1", "230", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.7", "95.2", "", "", "", "", "94.3"]} +{"pcdb_id": 15353, "brand_name": "Mistral", "model_name": "COD4 35/40", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 58.7, "output_kw_max": 40.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015353", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "COD4 35/40", "", "", "2007", "current", "4", "1", "2", "1", "0", "", "", "2", "3", "2", "35", "40", "", "", "88.1", "80.3", "", "58.7", "", "2", "", "", "201", "1", "1", "230", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.7", "95.2", "", "", "", "", "94.3"]} +{"pcdb_id": 15354, "brand_name": "Mistral", "model_name": "CODC3 26/35 plus", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 82.0, "comparative_hot_water_efficiency_pct": 50.4, "output_kw_max": 40.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015354", "000056", "0", "2024/Jan/31 10:17", "Mistral Boilers", "Mistral", "CODC3 26/35 plus", "", "", "2007", "current", "4", "1", "2", "2", "0", "", "", "2", "3", "2", "35", "40", "", "", "88.1", "82.0", "", "50.4", "", "2", "", "", "203", "1", "1", "230", "0", "2", "", "0", "35", "0", "25", "3", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.7", "95.2", "", "", "", "", "94.3"]} +{"pcdb_id": 15355, "brand_name": "Mistral", "model_name": "CODC 26/40 plus contract", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 82.0, "comparative_hot_water_efficiency_pct": 50.4, "output_kw_max": 40.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015355", "000056", "0", "2024/Jan/31 10:17", "Mistral Boilers", "Mistral", "CODC 26/40 plus contract", "", "", "2007", "current", "4", "1", "2", "2", "0", "", "", "2", "3", "2", "26", "40", "", "", "88.1", "82.0", "", "50.4", "", "2", "", "", "203", "1", "1", "230", "0", "2", "", "0", "35", "0", "25", "3", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.7", "95.2", "", "", "", "", "94.3"]} +{"pcdb_id": 15356, "brand_name": "Mistral", "model_name": "CODC4 35/40 plus", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 82.0, "comparative_hot_water_efficiency_pct": 50.4, "output_kw_max": 40.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015356", "000056", "0", "2024/Jan/31 10:17", "Mistral Boilers", "Mistral", "CODC4 35/40 plus", "", "", "2007", "current", "4", "1", "2", "2", "0", "", "", "2", "3", "2", "35", "40", "", "", "88.1", "82.0", "", "50.4", "", "2", "", "", "203", "1", "1", "230", "0", "2", "", "0", "35", "0", "25", "3", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.7", "95.2", "", "", "", "", "94.3"]} +{"pcdb_id": 15357, "brand_name": "Mistral", "model_name": "CC 26/40 plus contract", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 82.0, "comparative_hot_water_efficiency_pct": 50.2, "output_kw_max": 40.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015357", "000056", "0", "2024/Jan/31 10:17", "Mistral Boilers", "Mistral", "CC 26/40 plus contract", "", "", "2007", "current", "4", "1", "2", "2", "0", "", "", "2", "3", "2", "35", "40", "", "", "88.1", "82.0", "", "50.2", "", "2", "", "", "203", "1", "1", "230", "0", "2", "1", "0", "40", "0", "25", "3", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.7", "95.2", "", "", "", "", "94.3"]} +{"pcdb_id": 15358, "brand_name": "Mistral", "model_name": "CC4 35/40 plus", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 82.0, "comparative_hot_water_efficiency_pct": 50.4, "output_kw_max": 40.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015358", "000056", "0", "2024/Jan/31 10:17", "Mistral Boilers", "Mistral", "CC4 35/40 plus", "", "", "2007", "current", "4", "1", "1", "2", "0", "", "", "2", "3", "2", "35", "40", "", "", "88.1", "82.0", "", "50.4", "", "2", "", "", "203", "1", "1", "230", "0", "2", "", "0", "35", "0", "25", "3", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.7", "95.2", "", "", "", "", "94.3"]} +{"pcdb_id": 15359, "brand_name": "Mistral", "model_name": "CC3 26/35 plus", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 82.0, "comparative_hot_water_efficiency_pct": 50.4, "output_kw_max": 35.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015359", "000056", "0", "2024/Jan/31 10:17", "Mistral Boilers", "Mistral", "CC3 26/35 plus", "", "", "2007", "current", "4", "1", "1", "2", "0", "", "", "2", "3", "2", "26", "35", "", "", "88.1", "82.0", "", "50.4", "", "2", "", "", "203", "1", "1", "230", "0", "2", "", "0", "35", "0", "25", "3", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.7", "95.2", "", "", "", "", "94.3"]} +{"pcdb_id": 15360, "brand_name": "Mistral", "model_name": "CS 26/40 Contract", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 58.7, "output_kw_max": 40.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015360", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "CS 26/40 Contract", "", "", "2007", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "26", "40", "", "", "88.1", "80.3", "", "58.7", "", "2", "", "", "201", "1", "1", "230", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.7", "95.2", "", "", "", "", "94.3"]} +{"pcdb_id": 15361, "brand_name": "Mistral", "model_name": "CS3 26/35", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 58.7, "output_kw_max": 35.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015361", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "CS3 26/35", "", "", "2007", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "26", "35", "", "", "88.1", "80.3", "", "58.7", "", "2", "", "", "201", "1", "1", "230", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.7", "95.2", "", "", "", "", "94.3"]} +{"pcdb_id": 15362, "brand_name": "Mistral", "model_name": "CS4 35/40", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 58.7, "output_kw_max": 40.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015362", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "CS4 35/40", "", "", "2007", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "35", "40", "", "", "88.1", "80.3", "", "58.7", "", "2", "", "", "201", "1", "1", "230", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.7", "95.2", "", "", "", "", "94.3"]} +{"pcdb_id": 15363, "brand_name": "Mistral", "model_name": "CODSS 26/40 Contract", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 58.7, "output_kw_max": 40.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015363", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "CODSS 26/40 Contract", "", "", "2007", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "26", "40", "", "", "88.1", "80.3", "", "58.7", "", "2", "", "", "201", "1", "1", "230", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.7", "95.2", "", "", "", "", "94.3"]} +{"pcdb_id": 15364, "brand_name": "Mistral", "model_name": "CODSS 4 35/40", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 58.7, "output_kw_max": 40.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015364", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "CODSS 4 35/40", "", "", "2007", "current", "4", "1", "2", "1", "0", "", "", "2", "3", "2", "35", "40", "", "", "88.1", "80.3", "", "58.7", "", "2", "", "", "201", "1", "1", "230", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.7", "95.2", "", "", "", "", "94.3"]} +{"pcdb_id": 15365, "brand_name": "Mistral", "model_name": "CODSS 3 26/35", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 58.7, "output_kw_max": 35.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015365", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "CODSS 3 26/35", "", "", "2007", "current", "4", "1", "2", "1", "0", "", "", "2", "3", "2", "26", "35", "", "", "88.1", "80.3", "", "58.7", "", "2", "", "", "201", "1", "1", "230", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.7", "95.2", "", "", "", "", "94.3"]} +{"pcdb_id": 15366, "brand_name": "Atlantic Boilers", "model_name": "KDB", "model_qualifier": "251 KCA", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 56.0, "output_kw_max": 28.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015366", "000003", "0", "2023/Apr/27 08:50", "Atlantic 2000", "Atlantic Boilers", "KDB", "251 KCA", "", "2003", "obsolete", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "28.4", "28.4", "", "", "88.2", "79.6", "", "56.0", "", "2", "", "", "104", "1", "2", "145", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.5", "97.6", "", "", "", "", "95.7"]} +{"pcdb_id": 15367, "brand_name": "Atlantic Boilers", "model_name": "KDB", "model_qualifier": "201 KCA", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 55.9, "output_kw_max": 23.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015367", "000003", "0", "2023/Apr/27 08:50", "Atlantic 2000", "Atlantic Boilers", "KDB", "201 KCA", "", "2003", "obsolete", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "23.3", "23.3", "", "", "88.1", "79.5", "", "55.9", "", "2", "", "", "104", "1", "2", "145", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.7", "97.3", "", "", "", "", "95.5"]} +{"pcdb_id": 15368, "brand_name": "Atlantic Boilers", "model_name": "KDB", "model_qualifier": "301 KCA", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 56.1, "output_kw_max": 33.8, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015368", "000003", "0", "2023/Apr/27 08:50", "Atlantic 2000", "Atlantic Boilers", "KDB", "301 KCA", "", "2003", "obsolete", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "33.8", "33.8", "", "", "88.4", "79.8", "", "56.1", "", "2", "", "", "104", "1", "2", "145", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.3", "98.0", "", "", "", "", "96.0"]} +{"pcdb_id": 15369, "brand_name": "Atlantic Boilers", "model_name": "KDB", "model_qualifier": "181 KCA", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 56.0, "output_kw_max": 20.9, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015369", "000003", "0", "2023/Apr/27 08:50", "Atlantic 2000", "Atlantic Boilers", "KDB", "181 KCA", "", "2003", "obsolete", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "20.9", "20.9", "", "", "88.3", "79.7", "", "56.0", "", "2", "", "", "104", "1", "2", "145", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "97.5", "", "", "", "", "95.7"]} +{"pcdb_id": 15370, "brand_name": "Ariston", "model_name": "Clas HE 24", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 56.0, "output_kw_max": 21.0, "final_year_of_manufacture": 2013, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015370", "000080", "0", "2013/Nov/04 15:29", "Merloni TermoSanitari SpA", "Ariston", "Clas HE 24", "", "47-116-51", "2007", "2013", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "21", "21", "", "", "88.3", "79.7", "", "56.0", "", "2", "", "", "104", "1", "2", "120", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "97.3", "", "", "", "", "95.6"]} +{"pcdb_id": 15371, "brand_name": "Ariston", "model_name": "Clas HE 30", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 56.1, "output_kw_max": 27.0, "final_year_of_manufacture": 2013, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015371", "000080", "0", "2013/Nov/04 15:29", "Merloni TermoSanitari SpA", "Ariston", "Clas HE 30", "", "47-116-52", "2007", "2013", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "27", "27", "", "", "88.3", "79.7", "", "56.1", "", "2", "", "", "104", "1", "2", "120", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "97.5", "", "", "", "", "95.7"]} +{"pcdb_id": 15372, "brand_name": "Ariston", "model_name": "Genus HE 24", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 56.0, "output_kw_max": 21.0, "final_year_of_manufacture": 2013, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015372", "000080", "0", "2013/Nov/04 15:30", "Merloni TermoSanitari SpA", "Ariston", "Genus HE 24", "", "47-116-54", "2007", "2013", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "21", "21", "", "", "88.3", "79.7", "", "56.0", "", "2", "", "", "104", "1", "2", "120", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "97.3", "", "", "", "", "95.6"]} +{"pcdb_id": 15373, "brand_name": "Ariston", "model_name": "Genus HE 30", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 56.1, "output_kw_max": 27.0, "final_year_of_manufacture": 2013, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015373", "000080", "0", "2013/Nov/04 15:29", "Merloni TermoSanitari SpA", "Ariston", "Genus HE 30", "", "47-116-55", "2007", "2013", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "27", "27", "", "", "88.3", "79.7", "", "56.1", "", "2", "", "", "104", "1", "2", "120", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "97.5", "", "", "", "", "95.7"]} +{"pcdb_id": 15374, "brand_name": "Potterton", "model_name": "Promax System", "model_qualifier": "12 HE Plus", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 78.9, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 12.0, "final_year_of_manufacture": 2008, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015374", "000005", "0", "2012/Mar/27 10:12", "Baxi Heating", "Potterton", "Promax System", "12 HE Plus", "GC No. 41-591-90", "2007", "2008", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "12", "12", "", "", "87.9", "78.9", "", "57.7", "", "2", "", "", "102", "1", "2", "145", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "96.7", "", "", "", "", "95.0"]} +{"pcdb_id": 15375, "brand_name": "Potterton", "model_name": "Promax System", "model_qualifier": "15 HE Plus", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 15.0, "final_year_of_manufacture": 2008, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015375", "000005", "0", "2012/Mar/27 10:12", "Baxi Heating", "Potterton", "Promax System", "15 HE Plus", "GC No. 41-591-91", "2007", "2008", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "15", "15", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "130", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "96.8", "", "", "", "", "95.1"]} +{"pcdb_id": 15376, "brand_name": "Potterton", "model_name": "Promax System", "model_qualifier": "18 HE Plus", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 18.0, "final_year_of_manufacture": 2008, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015376", "000005", "0", "2012/Mar/27 10:12", "Baxi Heating", "Potterton", "Promax System", "18 HE Plus", "GC No. 41-591-92", "2007", "2008", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18", "18", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "140", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "96.9", "", "", "", "", "95.2"]} +{"pcdb_id": 15377, "brand_name": "Potterton", "model_name": "Promax System", "model_qualifier": "32 HE Plus", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 78.9, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 32.0, "final_year_of_manufacture": 2008, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015377", "000005", "0", "2012/Mar/27 10:12", "Baxi Heating", "Potterton", "Promax System", "32 HE Plus", "GC No. 41-591-93", "2007", "2008", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "32", "32", "", "", "87.9", "78.9", "", "57.7", "", "2", "", "", "102", "1", "2", "160", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "96.7", "", "", "", "", "95.0"]} +{"pcdb_id": 15379, "brand_name": "Biasi", "model_name": "Riva 30 OV", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 30.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015379", "000208", "0", "2012/Mar/27 10:12", "Halstead Boilers", "Biasi", "Riva 30 OV", "", "47-260-10", "2006", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "30", "30", "", "", "88.6", "79.6", "", "58.1", "", "2", "", "", "102", "1", "2", "50", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "98.3", "", "", "", "", "96.3"]} +{"pcdb_id": 15380, "brand_name": "Biasi", "model_name": "Riva 18 OV", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 18.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015380", "000208", "0", "2012/Mar/27 10:12", "Halstead Boilers", "Biasi", "Riva 18 OV", "", "47-260-09", "2006", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18", "18", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "80", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.7", "97.9", "", "", "", "", "96.0"]} +{"pcdb_id": 15381, "brand_name": "Glow-worm", "model_name": "Ultrapower 100 SXI", "model_qualifier": "", "winter_efficiency_pct": 89.3, "summer_efficiency_pct": 82.0, "comparative_hot_water_efficiency_pct": 55.3, "output_kw_max": 24.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015381", "000207", "0", "2024/Jan/31 10:17", "Vaillant Group UK", "Glow-worm", "Ultrapower 100 SXI", "", "", "2007", "current", "2", "1", "1", "2", "0", "", "", "2", "2", "2", "24.3", "24.3", "", "", "89.3", "82.0", "", "55.3", "", "2", "1", "", "106", "1", "2", "210", "15", "2", "1", "0", "80", "0", "50", "5", "62", "0.57", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "92.0", "98.9", "", "", "", "", "97.6"]} +{"pcdb_id": 15382, "brand_name": "Glow-worm", "model_name": "Ultrapower 170 SXI", "model_qualifier": "", "winter_efficiency_pct": 89.3, "summer_efficiency_pct": 82.0, "comparative_hot_water_efficiency_pct": 51.9, "output_kw_max": 24.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015382", "000207", "0", "2024/Jan/31 10:17", "Vaillant Group UK", "Glow-worm", "Ultrapower 170 SXI", "", "", "2007", "current", "2", "1", "1", "2", "0", "", "", "2", "2", "2", "24.3", "24.3", "", "", "89.3", "82.0", "", "51.9", "", "2", "1", "", "106", "1", "2", "210", "15", "2", "1", "0", "120", "0", "50", "5", "62", "0.57", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "92.0", "98.9", "", "", "", "", "97.6"]} +{"pcdb_id": 15385, "brand_name": "Ariston", "model_name": "Genus HE 38", "model_qualifier": "", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 55.8, "output_kw_max": 30.0, "final_year_of_manufacture": 2013, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015385", "000080", "0", "2014/Apr/15 14:59", "Merloni TermoSanitari SpA", "Ariston", "Genus HE 38", "", "47-116-56", "2007", "2013", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "30", "30", "", "", "87.9", "79.3", "", "55.8", "", "2", "", "", "104", "1", "2", "120", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "96.6", "", "", "", "", "94.9"]} +{"pcdb_id": 15386, "brand_name": "Ariston", "model_name": "Genus HE System 30", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 27.0, "final_year_of_manufacture": 2013, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015386", "000080", "0", "2013/Nov/04 15:27", "Merloni TermoSanitari SpA", "Ariston", "Genus HE System 30", "", "41-116-25", "2007", "2013", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "27", "27", "", "", "88.3", "79.3", "", "57.9", "", "2", "", "", "102", "1", "2", "120", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "97.5", "", "", "", "", "95.7"]} +{"pcdb_id": 15387, "brand_name": "Ariston", "model_name": "Genus HE 24 System", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 21.0, "final_year_of_manufacture": 2013, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015387", "000080", "0", "2013/Nov/04 15:26", "Merloni TermoSanitari SpA", "Ariston", "Genus HE 24 System", "", "41-116-24", "2007", "2013", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "21", "21", "", "", "88.3", "79.3", "", "57.9", "", "2", "", "", "102", "1", "2", "120", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "97.3", "", "", "", "", "95.6"]} +{"pcdb_id": 15388, "brand_name": "Ariston", "model_name": "Clas HE System 30", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 27.0, "final_year_of_manufacture": 2013, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015388", "000080", "0", "2013/Nov/04 15:26", "Merloni TermoSanitari SpA", "Ariston", "Clas HE System 30", "", "41-116-23", "2007", "2013", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "27", "27", "", "", "88.3", "79.3", "", "57.9", "", "2", "", "", "102", "1", "2", "120", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "97.5", "", "", "", "", "95.7"]} +{"pcdb_id": 15389, "brand_name": "Ariston", "model_name": "Clas HE 24 System", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 21.0, "final_year_of_manufacture": 2013, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015389", "000080", "0", "2013/Nov/04 15:27", "Merloni TermoSanitari SpA", "Ariston", "Clas HE 24 System", "", "41-116-22", "2007", "2013", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "21", "21", "", "", "88.3", "79.3", "", "57.9", "", "2", "", "", "102", "1", "2", "120", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "97.3", "", "", "", "", "95.6"]} +{"pcdb_id": 15391, "brand_name": "Ravenheat", "model_name": "CSI Primary 150 Low Nox", "model_qualifier": "", "winter_efficiency_pct": 89.3, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 58.7, "output_kw_max": 31.7, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015391", "000026", "0", "2012/Mar/27 10:12", "Ravenheat", "Ravenheat", "CSI Primary 150 Low Nox", "", "", "2007", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "31.7", "31.7", "", "", "89.3", "80.3", "", "58.7", "", "2", "1", "", "102", "1", "2", "40", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "91.3", "99.2", "", "", "", "", "97.7"]} +{"pcdb_id": 15392, "brand_name": "Ravenheat", "model_name": "CSI Primary 150 Low Nox", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 31.7, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015392", "000026", "0", "2012/Mar/27 10:12", "Ravenheat", "Ravenheat", "CSI Primary 150 Low Nox", "", "", "2007", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "31.7", "31.7", "", "", "88.3", "79.3", "", "57.9", "", "2", "", "", "102", "1", "2", "40", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.3", "97.0", "", "", "", "", "95.6"]} +{"pcdb_id": 15406, "brand_name": "Ravenheat", "model_name": "CSI 150 System T Low Nox", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 31.7, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015406", "000026", "0", "2012/Mar/27 10:12", "Ravenheat", "Ravenheat", "CSI 150 System T Low Nox", "", "", "2007", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "31.7", "31.7", "", "", "88.3", "79.3", "", "57.9", "", "2", "", "", "102", "1", "2", "160", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.3", "97.0", "", "", "", "", "95.6"]} +{"pcdb_id": 15407, "brand_name": "Ravenheat", "model_name": "CSI 150 System T Low Nox", "model_qualifier": "", "winter_efficiency_pct": 89.3, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 58.7, "output_kw_max": 31.7, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015407", "000026", "0", "2012/Mar/27 10:12", "Ravenheat", "Ravenheat", "CSI 150 System T Low Nox", "", "", "2007", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "31.7", "31.7", "", "", "89.3", "80.3", "", "58.7", "", "2", "1", "", "102", "1", "2", "160", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "91.3", "99.2", "", "", "", "", "97.7"]} +{"pcdb_id": 15421, "brand_name": "Ravenheat", "model_name": "CSI 150 T Low Nox", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 56.1, "output_kw_max": 31.7, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015421", "000026", "0", "2010/Oct/12 11:55", "Ravenheat", "Ravenheat", "CSI 150 T Low Nox", "", "", "2007", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "31.7", "31.7", "", "", "88.3", "79.7", "", "56.1", "", "2", "", "", "104", "1", "2", "160", "0", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.3", "97.0", "", "", "", "", "95.6"]} +{"pcdb_id": 15422, "brand_name": "Ravenheat", "model_name": "CSI 150 T Low Nox", "model_qualifier": "", "winter_efficiency_pct": 89.3, "summer_efficiency_pct": 80.7, "comparative_hot_water_efficiency_pct": 56.8, "output_kw_max": 31.7, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015422", "000026", "0", "2010/Sep/29 12:24", "Ravenheat", "Ravenheat", "CSI 150 T Low Nox", "", "", "2007", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "31.7", "31.7", "", "", "89.3", "80.7", "", "56.8", "", "2", "1", "", "104", "1", "2", "160", "0", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "91.3", "99.2", "", "", "", "", "97.7"]} +{"pcdb_id": 15425, "brand_name": "Vaillant", "model_name": "ecoTEC plus 837", "model_qualifier": "", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 56.0, "output_kw_max": 28.0, "final_year_of_manufacture": 2012, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015425", "000031", "0", "2019/Mar/04 10:17", "Vaillant", "Vaillant", "ecoTEC plus 837", "", "47- 044-33", "2007", "2012", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28.0", "28.0", "", "", "88.2", "79.6", "", "56.0", "", "2", "", "", "104", "1", "2", "155", "6", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.0", "96.4", "", "", "", "", "95.2"]} +{"pcdb_id": 15426, "brand_name": "Vaillant", "model_name": "ecoTEC plus 637", "model_qualifier": "", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 37.0, "final_year_of_manufacture": 2019, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015426", "000031", "0", "2019/Mar/04 10:11", "Vaillant", "Vaillant", "ecoTEC plus 637", "", "41-044-49", "2007", "2019", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "37.0", "37.0", "", "", "88.2", "79.2", "", "57.9", "", "2", "", "", "102", "1", "2", "155", "6", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.0", "96.5", "", "", "", "", "95.3"]} +{"pcdb_id": 15428, "brand_name": "Vaillant", "model_name": "ecoTEC plus 937", "model_qualifier": "", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 81.9, "comparative_hot_water_efficiency_pct": 53.3, "output_kw_max": 28.0, "final_year_of_manufacture": 2019, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015428", "000031", "0", "2024/Jan/31 10:17", "Vaillant", "Vaillant", "ecoTEC plus 937", "", "", "2007", "2019", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "28.0", "28.0", "", "", "89.2", "81.9", "", "53.3", "", "2", "1", "", "106", "1", "2", "175", "6.5", "2", "1", "0", "15", "0", "30", "5", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "92.0", "98.5", "", "", "", "", "97.3"]} +{"pcdb_id": 15429, "brand_name": "Vaillant", "model_name": "ecoTEC plus 937", "model_qualifier": "", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 80.9, "comparative_hot_water_efficiency_pct": 52.6, "output_kw_max": 28.0, "final_year_of_manufacture": 2012, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015429", "000031", "0", "2024/Jan/31 10:17", "Vaillant", "Vaillant", "ecoTEC plus 937", "", "47- 044-39", "2007", "2012", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28.0", "28.0", "", "", "88.2", "80.9", "", "52.6", "", "2", "", "", "106", "1", "2", "175", "6.5", "2", "1", "0", "15", "0", "30", "5", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.0", "96.4", "", "", "", "", "95.2"]} +{"pcdb_id": 15430, "brand_name": "Vaillant", "model_name": "ecoTEC plus 837", "model_qualifier": "", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 80.6, "comparative_hot_water_efficiency_pct": 56.7, "output_kw_max": 28.0, "final_year_of_manufacture": 2019, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015430", "000031", "0", "2019/Mar/04 10:16", "Vaillant", "Vaillant", "ecoTEC plus 837", "", "", "2007", "2019", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "28.0", "28.0", "", "", "89.2", "80.6", "", "56.7", "", "2", "1", "", "104", "1", "2", "155", "6", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "92.0", "98.5", "", "", "", "", "97.3"]} +{"pcdb_id": 15431, "brand_name": "Vaillant", "model_name": "ecoTEC plus 637", "model_qualifier": "", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 37.0, "final_year_of_manufacture": 2019, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015431", "000031", "0", "2019/Mar/04 10:10", "Vaillant", "Vaillant", "ecoTEC plus 637", "", "", "2007", "2019", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "37.0", "37.0", "", "", "89.2", "80.2", "", "58.6", "", "2", "1", "", "102", "1", "2", "155", "6", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "92.0", "98.5", "", "", "", "", "97.3"]} +{"pcdb_id": 15433, "brand_name": "Glow-worm", "model_name": "Ultracom 38hxi", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 38.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015433", "000207", "0", "2012/Mar/27 10:12", "Vaillant Group UK", "Glow-worm", "Ultracom 38hxi", "", "41-019-06", "2007", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "38.00", "38.00", "", "", "88.5", "79.5", "", "58.1", "", "2", "", "", "102", "1", "2", "60", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.3", "97.5", "", "", "", "", "95.9"]} +{"pcdb_id": 15436, "brand_name": "Glow-worm", "model_name": "Ultracom 38hxi", "model_qualifier": "", "winter_efficiency_pct": 89.5, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 58.8, "output_kw_max": 38.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015436", "000207", "0", "2012/Mar/27 10:12", "Vaillant Group UK", "Glow-worm", "Ultracom 38hxi", "", "", "2007", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "38.00", "38.00", "", "", "89.5", "80.5", "", "58.8", "", "2", "1", "", "102", "1", "2", "60", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "91.3", "99.7", "", "", "", "", "98.1"]} +{"pcdb_id": 15437, "brand_name": "Glow-worm", "model_name": "Ultracom 38cxi", "model_qualifier": "", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 55.8, "output_kw_max": 30.0, "final_year_of_manufacture": 2013, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015437", "000207", "0", "2013/Aug/23 09:31", "Vaillant Group UK", "Glow-worm", "Ultracom 38cxi", "", "47-019-03", "2007", "2013", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "30.0", "30.0", "", "", "87.9", "79.3", "", "55.8", "", "2", "", "", "104", "1", "2", "180", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.7", "96.3", "", "", "", "", "94.9"]} +{"pcdb_id": 15438, "brand_name": "Glow-worm", "model_name": "Ultracom 38cxi", "model_qualifier": "", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 56.5, "output_kw_max": 30.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015438", "000207", "0", "2010/Mar/06 17:44", "Vaillant Group UK", "Glow-worm", "Ultracom 38cxi", "", "", "2007", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "30.0", "30.0", "", "", "88.9", "80.3", "", "56.5", "", "2", "1", "", "104", "1", "2", "180", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.7", "98.5", "", "", "", "", "97.0"]} +{"pcdb_id": 15440, "brand_name": "Glow-worm", "model_name": "Ultracom 30sxi", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 28.17, "final_year_of_manufacture": 2013, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015440", "000207", "0", "2013/Aug/23 09:31", "Vaillant Group UK", "Glow-worm", "Ultracom 30sxi", "", "41-019-08", "2007", "2013", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "28.17", "28.17", "", "", "88.1", "79.1", "", "57.8", "", "2", "", "", "102", "1", "2", "180", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.7", "96.9", "", "", "", "", "95.3"]} +{"pcdb_id": 15442, "brand_name": "Glow-worm", "model_name": "Ultracom 30sxi", "model_qualifier": "", "winter_efficiency_pct": 90.0, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 59.2, "output_kw_max": 28.17, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015442", "000207", "0", "2012/Mar/27 10:12", "Vaillant Group UK", "Glow-worm", "Ultracom 30sxi", "", "", "2007", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "28.17", "28.17", "", "", "90.0", "81.0", "", "59.2", "", "2", "0", "", "102", "1", "2", "180", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.8", "99.0", "", "", "", "", "97.3"]} +{"pcdb_id": 15443, "brand_name": "Glow-worm", "model_name": "Ultracom 30hxi", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 28.17, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015443", "000207", "0", "2012/Mar/27 10:12", "Vaillant Group UK", "Glow-worm", "Ultracom 30hxi", "", "41-019-05", "2007", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "28.17", "28.17", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "60", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0085", "", "", "", "", "", "", "", "", "88.7", "96.4", "", "", "", "", "95.0"]} +{"pcdb_id": 15444, "brand_name": "Glow-worm", "model_name": "Ultracom 30hxi", "model_qualifier": "", "winter_efficiency_pct": 89.8, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 59.0, "output_kw_max": 28.17, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015444", "000207", "0", "2012/Mar/27 10:12", "Vaillant Group UK", "Glow-worm", "Ultracom 30hxi", "", "", "2007", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "28.17", "28.17", "", "", "89.8", "80.8", "", "59.0", "", "2", "0", "", "102", "1", "2", "60", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.8", "98.5", "", "", "", "", "96.9"]} +{"pcdb_id": 15445, "brand_name": "Glow-worm", "model_name": "Ultracom 30cxi", "model_qualifier": "", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 55.8, "output_kw_max": 22.94, "final_year_of_manufacture": 2013, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015445", "000207", "0", "2013/Aug/23 09:31", "Vaillant Group UK", "Glow-worm", "Ultracom 30cxi", "", "47-019-02", "2007", "2013", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "22.94", "22.94", "", "", "87.9", "79.3", "", "55.8", "", "2", "", "", "104", "1", "2", "180", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "96.4", "", "", "", "", "94.9"]} +{"pcdb_id": 15447, "brand_name": "Glow-worm", "model_name": "Ultracom 30cxi", "model_qualifier": "", "winter_efficiency_pct": 90.1, "summer_efficiency_pct": 81.5, "comparative_hot_water_efficiency_pct": 57.3, "output_kw_max": 22.94, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015447", "000207", "0", "2010/Mar/06 17:45", "Vaillant Group UK", "Glow-worm", "Ultracom 30cxi", "", "", "2007", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "22.94", "22.94", "", "", "90.1", "81.5", "", "57.3", "", "2", "0", "", "104", "1", "2", "180", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.1", "99.0", "", "", "", "", "97.3"]} +{"pcdb_id": 15448, "brand_name": "Glow-worm", "model_name": "Ultracom 30cx", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 55.9, "output_kw_max": 22.94, "final_year_of_manufacture": 2013, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015448", "000207", "0", "2013/Aug/23 09:31", "Vaillant Group UK", "Glow-worm", "Ultracom 30cx", "", "47-019-07", "2007", "2013", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "22.94", "22.94", "", "", "88.1", "79.5", "", "55.9", "", "2", "", "", "104", "1", "2", "180", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "96.9", "", "", "", "", "95.2"]} +{"pcdb_id": 15450, "brand_name": "Glow-worm", "model_name": "Ultracom 30cx", "model_qualifier": "", "winter_efficiency_pct": 90.1, "summer_efficiency_pct": 81.5, "comparative_hot_water_efficiency_pct": 57.3, "output_kw_max": 22.94, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015450", "000207", "0", "2010/Mar/06 17:45", "Vaillant Group UK", "Glow-worm", "Ultracom 30cx", "", "", "2007", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "22.94", "22.94", "", "", "90.1", "81.5", "", "57.3", "", "2", "0", "", "104", "1", "2", "180", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.1", "99.0", "", "", "", "", "97.3"]} +{"pcdb_id": 15451, "brand_name": "Glow-worm", "model_name": "Ultracom 24hxi", "model_qualifier": "", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 24.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015451", "000207", "0", "2012/Mar/27 10:12", "Vaillant Group UK", "Glow-worm", "Ultracom 24hxi", "", "41-019-04", "", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24.00", "24.00", "", "", "88.2", "79.2", "", "57.9", "", "2", "", "", "102", "1", "2", "60", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0085", "", "", "", "", "", "", "", "", "88.7", "97.0", "", "", "", "", "95.4"]} +{"pcdb_id": 15452, "brand_name": "Glow-worm", "model_name": "Ultracom 24hxi", "model_qualifier": "", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 24.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015452", "000207", "0", "2012/Mar/27 10:12", "Vaillant Group UK", "Glow-worm", "Ultracom 24hxi", "", "", "2007", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "24.00", "24.00", "", "", "89.2", "80.2", "", "58.6", "", "2", "1", "", "102", "1", "2", "60", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.6", "99.2", "", "", "", "", "97.6"]} +{"pcdb_id": 15453, "brand_name": "Glow-worm", "model_name": "Ultracom 24cxi", "model_qualifier": "", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 55.8, "output_kw_max": 18.0, "final_year_of_manufacture": 2013, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015453", "000207", "0", "2013/Aug/23 09:31", "Vaillant Group UK", "Glow-worm", "Ultracom 24cxi", "", "47-019-01", "2007", "2013", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "18.0", "18.0", "", "", "87.9", "79.3", "", "55.8", "", "2", "", "", "104", "1", "2", "180", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.6", "96.3", "", "", "", "", "94.8"]} +{"pcdb_id": 15454, "brand_name": "Glow-worm", "model_name": "Ultracom 24cxi", "model_qualifier": "", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 56.5, "output_kw_max": 18.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015454", "000207", "0", "2010/Mar/06 17:46", "Vaillant Group UK", "Glow-worm", "Ultracom 24cxi", "", "", "2007", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "18.0", "18.0", "", "", "88.9", "80.3", "", "56.5", "", "2", "1", "", "104", "1", "2", "180", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.5", "98.5", "", "", "", "", "96.9"]} +{"pcdb_id": 15455, "brand_name": "Glow-worm", "model_name": "Ultracom 24cx", "model_qualifier": "", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 55.8, "output_kw_max": 18.0, "final_year_of_manufacture": 2013, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015455", "000207", "0", "2013/Aug/23 09:30", "Vaillant Group UK", "Glow-worm", "Ultracom 24cx", "", "47-019-06", "2007", "2013", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "18.0", "18.0", "", "", "87.9", "79.3", "", "55.8", "", "2", "", "", "104", "1", "2", "180", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.6", "96.3", "", "", "", "", "94.8"]} +{"pcdb_id": 15456, "brand_name": "Glow-worm", "model_name": "Ultracom 24cx", "model_qualifier": "", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 56.5, "output_kw_max": 18.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015456", "000207", "0", "2010/Mar/06 17:46", "Vaillant Group UK", "Glow-worm", "Ultracom 24cx", "", "", "2007", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "18.0", "18.0", "", "", "88.9", "80.3", "", "56.5", "", "2", "1", "", "104", "1", "2", "180", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.5", "98.5", "", "", "", "", "96.9"]} +{"pcdb_id": 15458, "brand_name": "Glow-worm", "model_name": "Ultracom 18sxi", "model_qualifier": "", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 78.9, "comparative_hot_water_efficiency_pct": 57.6, "output_kw_max": 18.57, "final_year_of_manufacture": 2013, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015458", "000207", "0", "2013/Aug/23 09:30", "Vaillant Group UK", "Glow-worm", "Ultracom 18sxi", "", "41-019-07", "2007", "2013", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18.57", "18.57", "", "", "87.9", "78.9", "", "57.6", "", "2", "", "", "102", "1", "2", "180", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0085", "", "", "", "", "", "", "", "", "88.6", "96.3", "", "", "", "", "94.8"]} +{"pcdb_id": 15459, "brand_name": "Glow-worm", "model_name": "Ultracom 18sxi", "model_qualifier": "", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 18.57, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015459", "000207", "0", "2012/Mar/27 10:12", "Vaillant Group UK", "Glow-worm", "Ultracom 18sxi", "", "", "2007", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "18.57", "18.57", "", "", "88.9", "79.9", "", "58.4", "", "2", "1", "", "102", "1", "2", "180", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.5", "98.5", "", "", "", "", "96.9"]} +{"pcdb_id": 15460, "brand_name": "Glow-worm", "model_name": "Ultracom 18hxi", "model_qualifier": "", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 78.9, "comparative_hot_water_efficiency_pct": 57.6, "output_kw_max": 18.57, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015460", "000207", "0", "2012/Mar/27 10:12", "Vaillant Group UK", "Glow-worm", "Ultracom 18hxi", "", "41-019-03", "2007", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18.57", "18.57", "", "", "87.9", "78.9", "", "57.6", "", "2", "", "", "102", "1", "2", "60", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.6", "96.3", "", "", "", "", "94.8"]} +{"pcdb_id": 15461, "brand_name": "Glow-worm", "model_name": "Ultracom 18hxi", "model_qualifier": "", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 18.57, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015461", "000207", "0", "2012/Mar/27 10:12", "Vaillant Group UK", "Glow-worm", "Ultracom 18hxi", "", "", "2007", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "18.57", "18.57", "", "", "88.9", "79.9", "", "58.4", "", "2", "1", "", "102", "1", "2", "60", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.5", "98.5", "", "", "", "", "96.9"]} +{"pcdb_id": 15462, "brand_name": "Glow-worm", "model_name": "Ultracom 15hxi", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 15.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015462", "000207", "0", "2012/Mar/27 10:12", "Vaillant Group UK", "Glow-worm", "Ultracom 15hxi", "", "41-019-02", "2007", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "15.00", "15.00", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "60", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0085", "", "", "", "", "", "", "", "", "88.6", "96.5", "", "", "", "", "95.0"]} +{"pcdb_id": 15463, "brand_name": "Glow-worm", "model_name": "Ultracom 15hxi", "model_qualifier": "", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 15.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015463", "000207", "0", "2012/Mar/27 10:12", "Vaillant Group UK", "Glow-worm", "Ultracom 15hxi", "", "", "2007", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "15.00", "15.00", "", "", "89.0", "80.0", "", "58.4", "", "2", "1", "", "102", "1", "2", "60", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.5", "98.6", "", "", "", "", "97.1"]} +{"pcdb_id": 15464, "brand_name": "Glow-worm", "model_name": "Ultracom 12hxi", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 12.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015464", "000207", "0", "2012/Mar/27 10:12", "Vaillant Group UK", "Glow-worm", "Ultracom 12hxi", "", "41-019-01", "2007", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "12.00", "12.00", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "60", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0085", "", "", "", "", "", "", "", "", "88.7", "96.5", "", "", "", "", "95.0"]} +{"pcdb_id": 15465, "brand_name": "Glow-worm", "model_name": "Ultracom 12hxi", "model_qualifier": "", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 12.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015465", "000207", "0", "2012/Mar/27 10:12", "Vaillant Group UK", "Glow-worm", "Ultracom 12hxi", "", "", "2007", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "12.00", "12.00", "", "", "89.0", "80.0", "", "58.4", "", "2", "1", "", "102", "1", "2", "60", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.6", "98.6", "", "", "", "", "97.1"]} +{"pcdb_id": 15466, "brand_name": "Thermeco", "model_name": "BWIC 12/16", "model_qualifier": "", "winter_efficiency_pct": 86.1, "summer_efficiency_pct": 78.3, "comparative_hot_water_efficiency_pct": 57.2, "output_kw_max": 16.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015466", "000051", "0", "2012/Mar/27 10:12", "GAH Heating Products", "Thermeco", "BWIC 12/16", "", "", "2007", "current", "4", "2", "1", "1", "0", "", "", "2", "3", "2", "12", "16", "", "", "86.1", "78.3", "", "57.2", "", "2", "", "", "201", "1", "1", "75", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "88.9", "91.2", "", "", "", "", "90.7"]} +{"pcdb_id": 15467, "brand_name": "Thermeco", "model_name": "BFIC 12/24", "model_qualifier": "", "winter_efficiency_pct": 87.6, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 23.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015467", "000051", "0", "2012/Mar/27 10:12", "GAH Heating Products", "Thermeco", "BFIC 12/24", "", "", "2007", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "12", "23", "", "", "87.6", "79.8", "", "58.3", "", "2", "", "", "201", "1", "1", "75", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.3", "94.1", "", "", "", "", "93.4"]} +{"pcdb_id": 15468, "brand_name": "Thermeco", "model_name": "BFISC 12/24", "model_qualifier": "", "winter_efficiency_pct": 87.6, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 23.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015468", "000051", "0", "2012/Mar/27 10:12", "GAH Heating Products", "Thermeco", "BFISC 12/24", "", "", "2007", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "12", "23", "", "", "87.6", "79.8", "", "58.3", "", "2", "", "", "201", "1", "1", "75", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.3", "94.1", "", "", "", "", "93.4"]} +{"pcdb_id": 15469, "brand_name": "Thermeco", "model_name": "BFEC 12/24", "model_qualifier": "", "winter_efficiency_pct": 87.6, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 23.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015469", "000051", "0", "2012/Mar/27 10:12", "GAH Heating Products", "Thermeco", "BFEC 12/24", "", "", "2007", "current", "4", "1", "2", "1", "0", "", "", "2", "1", "2", "12", "23", "", "", "87.6", "79.8", "", "58.3", "", "2", "", "", "201", "1", "1", "75", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.3", "94.1", "", "", "", "", "93.4"]} +{"pcdb_id": 15470, "brand_name": "Thermeco", "model_name": "BFESC 12/24", "model_qualifier": "", "winter_efficiency_pct": 87.6, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 23.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015470", "000051", "0", "2012/Mar/27 10:12", "GAH Heating Products", "Thermeco", "BFESC 12/24", "", "", "2007", "current", "4", "1", "2", "1", "0", "", "", "2", "1", "2", "12", "23", "", "", "87.6", "79.8", "", "58.3", "", "2", "", "", "201", "1", "1", "75", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.3", "94.1", "", "", "", "", "93.4"]} +{"pcdb_id": 15471, "brand_name": "Thermeco", "model_name": "BWEC 12/16", "model_qualifier": "", "winter_efficiency_pct": 86.1, "summer_efficiency_pct": 78.3, "comparative_hot_water_efficiency_pct": 57.2, "output_kw_max": 16.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015471", "000051", "0", "2012/Mar/27 10:12", "GAH Heating Products", "Thermeco", "BWEC 12/16", "", "", "2007", "current", "4", "2", "2", "1", "0", "", "", "2", "1", "2", "12", "16", "", "", "86.1", "78.3", "", "57.2", "", "2", "", "", "201", "1", "1", "75", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "88.9", "91.2", "", "", "", "", "90.7"]} +{"pcdb_id": 15472, "brand_name": "Thermeco", "model_name": "BWESC 12/16", "model_qualifier": "", "winter_efficiency_pct": 86.1, "summer_efficiency_pct": 78.3, "comparative_hot_water_efficiency_pct": 57.2, "output_kw_max": 16.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015472", "000051", "0", "2012/Mar/27 10:12", "GAH Heating Products", "Thermeco", "BWESC 12/16", "", "", "2007", "current", "4", "2", "2", "1", "0", "", "", "2", "1", "2", "12", "16", "", "", "86.1", "78.3", "", "57.2", "", "2", "", "", "201", "1", "1", "75", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "88.9", "91.2", "", "", "", "", "90.7"]} +{"pcdb_id": 15473, "brand_name": "Thermeco", "model_name": "BWISC 12/16", "model_qualifier": "", "winter_efficiency_pct": 86.1, "summer_efficiency_pct": 78.3, "comparative_hot_water_efficiency_pct": 57.2, "output_kw_max": 16.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015473", "000051", "0", "2012/Mar/27 10:12", "GAH Heating Products", "Thermeco", "BWISC 12/16", "", "", "2007", "current", "4", "2", "1", "1", "0", "", "", "2", "3", "2", "12", "16", "", "", "86.1", "78.3", "", "57.2", "", "2", "", "", "201", "1", "1", "75", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "88.9", "91.2", "", "", "", "", "90.7"]} +{"pcdb_id": 15474, "brand_name": "Turco", "model_name": "Ambassador", "model_qualifier": "15/21 Kitchen", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 81.4, "comparative_hot_water_efficiency_pct": 59.5, "output_kw_max": 22.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015474", "000218", "0", "2012/Mar/27 10:12", "Turkington Engineering", "Turco", "Ambassador", "15/21 Kitchen", "", "2007", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "15", "22.3", "", "", "89.2", "81.4", "", "59.5", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.3", "97.7", "", "", "", "", "96.5"]} +{"pcdb_id": 15475, "brand_name": "Turco", "model_name": "Countryman", "model_qualifier": "15/21 Outdoor Combi", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 81.8, "comparative_hot_water_efficiency_pct": 57.5, "output_kw_max": 22.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015475", "000218", "0", "2007/Jul/20 08:44", "Turkington Engineering", "Turco", "Countryman", "15/21 Outdoor Combi", "", "2007", "current", "4", "1", "2", "2", "0", "", "", "2", "3", "1", "15", "22.3", "", "", "89.2", "81.8", "", "57.5", "", "2", "", "", "202", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.3", "97.7", "", "", "", "", "96.5"]} +{"pcdb_id": 15476, "brand_name": "Turco", "model_name": "Senator", "model_qualifier": "15/21 Combi", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 81.8, "comparative_hot_water_efficiency_pct": 57.5, "output_kw_max": 22.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015476", "000218", "0", "2007/Jul/20 08:44", "Turkington Engineering", "Turco", "Senator", "15/21 Combi", "", "2007", "current", "4", "1", "2", "2", "0", "", "", "2", "3", "1", "15", "22.3", "", "", "89.2", "81.8", "", "57.5", "", "2", "", "", "202", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.3", "97.7", "", "", "", "", "96.5"]} +{"pcdb_id": 15477, "brand_name": "Turco", "model_name": "Countryman", "model_qualifier": "15/21 Slimline Outdoor", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 81.4, "comparative_hot_water_efficiency_pct": 59.5, "output_kw_max": 22.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015477", "000218", "0", "2012/Mar/27 10:12", "Turkington Engineering", "Turco", "Countryman", "15/21 Slimline Outdoor", "", "2007", "current", "4", "1", "2", "1", "0", "", "", "2", "3", "1", "15", "22.3", "", "", "89.2", "81.4", "", "59.5", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.3", "97.7", "", "", "", "", "96.5"]} +{"pcdb_id": 15478, "brand_name": "Turco", "model_name": "Consul", "model_qualifier": "15/21 Boilerhouse", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 81.4, "comparative_hot_water_efficiency_pct": 59.5, "output_kw_max": 22.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015478", "000218", "0", "2012/Mar/27 10:12", "Turkington Engineering", "Turco", "Consul", "15/21 Boilerhouse", "", "2007", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "15", "22.3", "", "", "89.2", "81.4", "", "59.5", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.3", "97.7", "", "", "", "", "96.5"]} +{"pcdb_id": 15479, "brand_name": "Eurocal", "model_name": "Countryman", "model_qualifier": "15/21 Outdoor Combi", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 81.8, "comparative_hot_water_efficiency_pct": 57.5, "output_kw_max": 22.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015479", "000218", "0", "2007/Jul/20 08:49", "Turkington Engineering", "Eurocal", "Countryman", "15/21 Outdoor Combi", "", "2007", "current", "4", "1", "2", "2", "0", "", "", "2", "3", "1", "15", "22.3", "", "", "89.2", "81.8", "", "57.5", "", "2", "", "", "202", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.3", "97.7", "", "", "", "", "96.5"]} +{"pcdb_id": 15480, "brand_name": "Eurocal", "model_name": "Senator", "model_qualifier": "15/21 Combi", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 81.8, "comparative_hot_water_efficiency_pct": 57.5, "output_kw_max": 22.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015480", "000218", "0", "2007/Jul/20 08:50", "Turkington Engineering", "Eurocal", "Senator", "15/21 Combi", "", "2007", "current", "4", "1", "1", "2", "0", "", "", "2", "3", "1", "15", "22.3", "", "", "89.2", "81.8", "", "57.5", "", "2", "", "", "202", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.3", "97.7", "", "", "", "", "96.5"]} +{"pcdb_id": 15481, "brand_name": "Eurocal", "model_name": "Countryman", "model_qualifier": "15/21 Slimline Outdoor", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 81.4, "comparative_hot_water_efficiency_pct": 59.5, "output_kw_max": 22.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015481", "000218", "0", "2012/Mar/27 10:12", "Turkington Engineering", "Eurocal", "Countryman", "15/21 Slimline Outdoor", "", "2007", "current", "4", "1", "2", "1", "0", "", "", "2", "3", "1", "15", "22.3", "", "", "89.2", "81.4", "", "59.5", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.3", "97.7", "", "", "", "", "96.5"]} +{"pcdb_id": 15482, "brand_name": "Eurocal", "model_name": "Ambassador", "model_qualifier": "15/21 Kitchen", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 81.4, "comparative_hot_water_efficiency_pct": 59.5, "output_kw_max": 22.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015482", "000218", "0", "2012/Mar/27 10:12", "Turkington Engineering", "Eurocal", "Ambassador", "15/21 Kitchen", "", "2007", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "15", "22.3", "", "", "89.2", "81.4", "", "59.5", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.3", "97.7", "", "", "", "", "96.5"]} +{"pcdb_id": 15483, "brand_name": "Turco", "model_name": "Ambassador", "model_qualifier": "21/27 Kitchen", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 59.2, "output_kw_max": 27.9, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015483", "000218", "0", "2012/Mar/27 10:12", "Turkington Engineering", "Turco", "Ambassador", "21/27 Kitchen", "", "2007", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "21", "27.9", "", "", "88.8", "81.0", "", "59.2", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "89.5", "97.4", "", "", "", "", "95.9"]} +{"pcdb_id": 15484, "brand_name": "Turco", "model_name": "Countryman", "model_qualifier": "21/27 Outdoor Combi", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 81.4, "comparative_hot_water_efficiency_pct": 57.3, "output_kw_max": 27.9, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015484", "000218", "0", "2007/Jul/20 08:52", "Turkington Engineering", "Turco", "Countryman", "21/27 Outdoor Combi", "", "2007", "current", "4", "1", "2", "2", "0", "", "", "2", "3", "1", "21", "27.9", "", "", "88.8", "81.4", "", "57.3", "", "2", "", "", "202", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "89.5", "97.4", "", "", "", "", "95.9"]} +{"pcdb_id": 15485, "brand_name": "Turco", "model_name": "Senator", "model_qualifier": "21/27 Combi", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 81.4, "comparative_hot_water_efficiency_pct": 57.3, "output_kw_max": 27.9, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015485", "000218", "0", "2007/Jul/20 08:52", "Turkington Engineering", "Turco", "Senator", "21/27 Combi", "", "2007", "current", "4", "1", "1", "2", "0", "", "", "2", "3", "1", "21", "27.9", "", "", "88.8", "81.4", "", "57.3", "", "2", "", "", "202", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "89.5", "97.4", "", "", "", "", "95.9"]} +{"pcdb_id": 15486, "brand_name": "Turco", "model_name": "Countryman", "model_qualifier": "21/27 Slimline Outdoor", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 59.2, "output_kw_max": 27.9, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015486", "000218", "0", "2012/Mar/27 10:12", "Turkington Engineering", "Turco", "Countryman", "21/27 Slimline Outdoor", "", "2007", "current", "4", "1", "2", "1", "0", "", "", "2", "3", "1", "21", "27.9", "", "", "88.8", "81.0", "", "59.2", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "89.5", "97.4", "", "", "", "", "95.9"]} +{"pcdb_id": 15487, "brand_name": "Eurocal", "model_name": "Countryman", "model_qualifier": "21/27 Outdoor Combi", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 81.4, "comparative_hot_water_efficiency_pct": 57.3, "output_kw_max": 27.9, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015487", "000218", "0", "2007/Jul/20 08:53", "Turkington Engineering", "Eurocal", "Countryman", "21/27 Outdoor Combi", "", "2007", "current", "4", "1", "2", "2", "0", "", "", "2", "3", "1", "21", "27.9", "", "", "88.8", "81.4", "", "57.3", "", "2", "", "", "202", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "89.5", "97.4", "", "", "", "", "95.9"]} +{"pcdb_id": 15488, "brand_name": "Eurocal", "model_name": "Senator", "model_qualifier": "21/27 Combi", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 81.4, "comparative_hot_water_efficiency_pct": 57.3, "output_kw_max": 27.9, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015488", "000218", "0", "2007/Jul/20 08:53", "Turkington Engineering", "Eurocal", "Senator", "21/27 Combi", "", "2007", "current", "4", "1", "1", "2", "0", "", "", "2", "3", "1", "21", "27.9", "", "", "88.8", "81.4", "", "57.3", "", "2", "", "", "202", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "89.5", "97.4", "", "", "", "", "95.9"]} +{"pcdb_id": 15489, "brand_name": "Eurocal", "model_name": "Countryman", "model_qualifier": "21/27 Slimline Outdoor", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 59.2, "output_kw_max": 27.9, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015489", "000218", "0", "2012/Mar/27 10:12", "Turkington Engineering", "Eurocal", "Countryman", "21/27 Slimline Outdoor", "", "2007", "current", "4", "1", "2", "1", "0", "", "", "2", "3", "1", "21", "27.9", "", "", "88.8", "81.0", "", "59.2", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "89.5", "97.4", "", "", "", "", "95.9"]} +{"pcdb_id": 15490, "brand_name": "Eurocal", "model_name": "Ambassador", "model_qualifier": "21/27 Kitchen", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 59.2, "output_kw_max": 27.9, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015490", "000218", "0", "2012/Mar/27 10:12", "Turkington Engineering", "Eurocal", "Ambassador", "21/27 Kitchen", "", "2007", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "21", "27.9", "", "", "88.8", "81.0", "", "59.2", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "89.5", "97.4", "", "", "", "", "95.9"]} +{"pcdb_id": 15491, "brand_name": "Turco", "model_name": "Ambassador", "model_qualifier": "27/38 Kitchen", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 59.2, "output_kw_max": 37.8, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015491", "000218", "0", "2012/Mar/27 10:12", "Turkington Engineering", "Turco", "Ambassador", "27/38 Kitchen", "", "2007", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "27", "37.8", "", "", "88.8", "81.0", "", "59.2", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.2", "97.1", "", "", "", "", "95.8"]} +{"pcdb_id": 15492, "brand_name": "Turco", "model_name": "Countryman", "model_qualifier": "27/38 Outdoor Combi", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 81.4, "comparative_hot_water_efficiency_pct": 57.2, "output_kw_max": 37.8, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015492", "000218", "0", "2007/Jul/20 09:04", "Turkington Engineering", "Turco", "Countryman", "27/38 Outdoor Combi", "", "2007", "current", "4", "1", "2", "2", "0", "", "", "2", "3", "1", "27", "37.8", "", "", "88.8", "81.4", "", "57.2", "", "2", "", "", "202", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.2", "97.1", "", "", "", "", "95.8"]} +{"pcdb_id": 15493, "brand_name": "Turco", "model_name": "Senator", "model_qualifier": "27/38 Combi", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 81.4, "comparative_hot_water_efficiency_pct": 57.2, "output_kw_max": 37.8, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015493", "000218", "0", "2007/Jul/20 09:06", "Turkington Engineering", "Turco", "Senator", "27/38 Combi", "", "2007", "current", "4", "1", "1", "2", "0", "", "", "2", "3", "1", "27", "37.8", "", "", "88.8", "81.4", "", "57.2", "", "2", "", "", "202", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.2", "97.1", "", "", "", "", "95.8"]} +{"pcdb_id": 15494, "brand_name": "Turco", "model_name": "Countryman", "model_qualifier": "27/38 Slimline Outdoor", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 59.2, "output_kw_max": 37.8, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015494", "000218", "0", "2012/Mar/27 10:12", "Turkington Engineering", "Turco", "Countryman", "27/38 Slimline Outdoor", "", "2007", "current", "4", "1", "2", "1", "0", "", "", "2", "3", "1", "27", "37.8", "", "", "88.8", "81.0", "", "59.2", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.2", "97.1", "", "", "", "", "95.8"]} +{"pcdb_id": 15495, "brand_name": "Eurocal", "model_name": "Countryman", "model_qualifier": "27/38 Outdoor Combi", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 81.4, "comparative_hot_water_efficiency_pct": 57.2, "output_kw_max": 37.8, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015495", "000218", "0", "2007/Jul/20 09:06", "Turkington Engineering", "Eurocal", "Countryman", "27/38 Outdoor Combi", "", "2007", "current", "4", "1", "2", "2", "0", "", "", "2", "3", "1", "27", "37.8", "", "", "88.8", "81.4", "", "57.2", "", "2", "", "", "202", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.2", "97.1", "", "", "", "", "95.8"]} +{"pcdb_id": 15496, "brand_name": "Eurocal", "model_name": "Senator", "model_qualifier": "27/38 Combi", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 81.4, "comparative_hot_water_efficiency_pct": 57.2, "output_kw_max": 37.8, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015496", "000218", "0", "2007/Jul/20 09:06", "Turkington Engineering", "Eurocal", "Senator", "27/38 Combi", "", "2007", "current", "4", "1", "1", "2", "0", "", "", "2", "3", "1", "27", "37.8", "", "", "88.8", "81.4", "", "57.2", "", "2", "", "", "202", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.2", "97.1", "", "", "", "", "95.8"]} +{"pcdb_id": 15498, "brand_name": "Eurocal", "model_name": "Ambassador", "model_qualifier": "27/38 Kitchen", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 59.2, "output_kw_max": 37.8, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015498", "000218", "0", "2012/Mar/27 10:12", "Turkington Engineering", "Eurocal", "Ambassador", "27/38 Kitchen", "", "2007", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "27", "37.8", "", "", "88.8", "81.0", "", "59.2", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.2", "97.1", "", "", "", "", "95.8"]} +{"pcdb_id": 15499, "brand_name": "Eurocal", "model_name": "Countryman", "model_qualifier": "27/38 Slimline Outdoor", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 81.4, "comparative_hot_water_efficiency_pct": 57.2, "output_kw_max": 37.8, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015499", "000218", "0", "2007/Jul/20 09:08", "Turkington Engineering", "Eurocal", "Countryman", "27/38 Slimline Outdoor", "", "2007", "current", "4", "1", "2", "2", "0", "", "", "2", "3", "1", "27", "37.8", "", "", "88.8", "81.4", "", "57.2", "", "2", "", "", "202", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.2", "97.1", "", "", "", "", "95.8"]} +{"pcdb_id": 15501, "brand_name": "Vaillant", "model_name": "ecoTEC pro 24", "model_qualifier": "", "winter_efficiency_pct": 89.3, "summer_efficiency_pct": 80.7, "comparative_hot_water_efficiency_pct": 56.7, "output_kw_max": 19.0, "final_year_of_manufacture": 2019, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015501", "000031", "0", "2019/Mar/04 10:25", "Vaillant", "Vaillant", "ecoTEC pro 24", "", "", "2007", "2019", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "19.0", "19.0", "", "", "89.3", "80.7", "", "56.7", "", "2", "1", "", "104", "1", "2", "110", "6", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "92.0", "98.8", "", "", "", "", "97.5"]} +{"pcdb_id": 15502, "brand_name": "Vaillant", "model_name": "ecoTEC pro 24", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 56.0, "output_kw_max": 19.0, "final_year_of_manufacture": 2012, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015502", "000031", "0", "2019/Mar/04 10:26", "Vaillant", "Vaillant", "ecoTEC pro 24", "", "47- 044-36", "2007", "2012", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "19.0", "19.0", "", "", "88.3", "79.7", "", "56.0", "", "2", "", "", "104", "1", "2", "110", "6", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.0", "96.7", "", "", "", "", "95.4"]} +{"pcdb_id": 15503, "brand_name": "Maxol", "model_name": "Supacombi", "model_qualifier": "HE 24", "winter_efficiency_pct": 85.8, "summer_efficiency_pct": 77.2, "comparative_hot_water_efficiency_pct": 60.3, "output_kw_max": 24.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015503", "000019", "0", "2007/Dec/20 13:38", "Halstead Boilers", "Maxol", "Supacombi", "HE 24", "47-260-11", "2007", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.6", "24.6", "", "", "85.8", "77.2", "", "60.3", "", "2", "", "", "104", "1", "2", "118", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "", "0005", "", "", "", "", "", "", "", "", "88.7", "90.9", "", "", "", "", "90.5"]} +{"pcdb_id": 15505, "brand_name": "Maxol", "model_name": "Supacombi", "model_qualifier": "HE 28", "winter_efficiency_pct": 85.9, "summer_efficiency_pct": 77.3, "comparative_hot_water_efficiency_pct": 60.3, "output_kw_max": 28.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015505", "000019", "0", "2007/Dec/20 13:38", "Halstead Boilers", "Maxol", "Supacombi", "HE 28", "47-260-12", "2007", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28.3", "28.3", "", "", "85.9", "77.3", "", "60.3", "", "2", "", "", "104", "1", "2", "130", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "", "0005", "", "", "", "", "", "", "", "", "87.9", "91.5", "", "", "", "", "90.8"]} +{"pcdb_id": 15506, "brand_name": "Express", "model_name": "BC", "model_qualifier": "24 Combi", "winter_efficiency_pct": 85.8, "summer_efficiency_pct": 77.2, "comparative_hot_water_efficiency_pct": 60.3, "output_kw_max": 24.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015506", "000019", "0", "2007/Dec/20 13:38", "Halstead Boilers", "Express", "BC", "24 Combi", "", "2007", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.6", "24.6", "", "", "85.8", "77.2", "", "60.3", "", "2", "", "", "104", "1", "2", "118", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "", "0005", "", "", "", "", "", "", "", "", "88.7", "90.9", "", "", "", "", "90.5"]} +{"pcdb_id": 15507, "brand_name": "Express", "model_name": "BC", "model_qualifier": "28 Combi", "winter_efficiency_pct": 85.9, "summer_efficiency_pct": 77.3, "comparative_hot_water_efficiency_pct": 60.3, "output_kw_max": 28.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015507", "000019", "0", "2007/Dec/20 13:38", "Halstead Boilers", "Express", "BC", "28 Combi", "", "2007", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28.3", "28.3", "", "", "85.9", "77.3", "", "60.3", "", "2", "", "", "104", "1", "2", "130", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "", "0005", "", "", "", "", "", "", "", "", "87.9", "91.5", "", "", "", "", "90.8"]} +{"pcdb_id": 15508, "brand_name": "Gerkros", "model_name": "50 70 Oil Condensing Boiler", "model_qualifier": "Utility Model", "winter_efficiency_pct": 87.0, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 20.69, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015508", "000245", "0", "2012/Mar/27 10:12", "Gerkros Boilers (Tipperary) Limited", "Gerkros", "50 70 Oil Condensing Boiler", "Utility Model", "", "2007", "obsolete", "4", "1", "2", "1", "0", "", "", "2", "3", "1", "14.65", "20.69", "", "", "87.0", "79.2", "", "57.9", "", "2", "", "", "201", "1", "1", "250", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "89.4", "93.0", "", "", "", "", "92.3"]} +{"pcdb_id": 15509, "brand_name": "Gerkros", "model_name": "70 90 Oil Condensing Boiler", "model_qualifier": "Utility Model", "winter_efficiency_pct": 87.3, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 27.06, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015509", "000245", "0", "2012/Mar/27 10:12", "Gerkros Boilers (Tipperary) Limited", "Gerkros", "70 90 Oil Condensing Boiler", "Utility Model", "", "2007", "current", "4", "1", "2", "1", "0", "", "", "2", "3", "1", "20.69", "27.06", "", "", "87.3", "79.5", "", "58.1", "", "2", "", "", "201", "1", "1", "250", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "89.7", "93.5", "", "", "", "", "92.8"]} +{"pcdb_id": 15510, "brand_name": "Gerkros", "model_name": "90 120 Oil Condensing Boiler", "model_qualifier": "Utility Model", "winter_efficiency_pct": 87.1, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 35.67, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015510", "000245", "0", "2012/Mar/27 10:12", "Gerkros Boilers (Tipperary) Limited", "Gerkros", "90 120 Oil Condensing Boiler", "Utility Model", "", "2007", "current", "4", "1", "2", "1", "0", "", "", "2", "3", "1", "27.06", "35.67", "", "", "87.1", "79.3", "", "57.9", "", "2", "", "", "201", "1", "1", "250", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.0", "92.8", "", "", "", "", "92.2"]} +{"pcdb_id": 15511, "brand_name": "Atlantic Boilers", "model_name": "KDB-200NHC", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 80.9, "comparative_hot_water_efficiency_pct": 56.9, "output_kw_max": 25.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015511", "000003", "0", "2023/Apr/27 08:50", "Atlantic 2000", "Atlantic Boilers", "KDB-200NHC", "", "", "2007", "obsolete", "4", "1", "1", "2", "0", "", "", "2", "3", "2", "23.8", "25.0", "", "", "88.3", "80.9", "", "56.9", "", "2", "", "", "202", "1", "1", "143", "5", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "93.6", "94.4", "", "", "", "", "94.3"]} +{"pcdb_id": 15512, "brand_name": "Atlantic Boilers", "model_name": "KDB-350NHC", "model_qualifier": "", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 56.8, "output_kw_max": 40.7, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015512", "000003", "0", "2023/Apr/27 08:50", "Atlantic 2000", "Atlantic Boilers", "KDB-350NHC", "", "", "2007", "obsolete", "4", "1", "1", "2", "0", "", "", "2", "3", "2", "37.8", "40.7", "", "", "88.2", "80.8", "", "56.8", "", "2", "", "", "202", "1", "1", "199", "5", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "93.6", "94.1", "", "", "", "", "94.0"]} +{"pcdb_id": 15514, "brand_name": "Vaillant", "model_name": "ecoTEC exclusive 838", "model_qualifier": "", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 56.0, "output_kw_max": 30.0, "final_year_of_manufacture": 2016, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015514", "000031", "0", "2015/Sep/21 14:23", "Vaillant", "Vaillant", "ecoTEC exclusive 838", "", "47- 044-38", "2007", "2016", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "30.0", "30.0", "", "", "88.2", "79.6", "", "56.0", "", "2", "", "", "104", "1", "2", "110", "6", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0045", "", "", "", "", "", "", "", "", "90.0", "96.6", "", "", "", "", "95.3"]} +{"pcdb_id": 15515, "brand_name": "Vaillant", "model_name": "ecoTEC exclusive 838", "model_qualifier": "", "winter_efficiency_pct": 89.3, "summer_efficiency_pct": 80.7, "comparative_hot_water_efficiency_pct": 56.7, "output_kw_max": 30.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015515", "000031", "0", "2009/Oct/28 09:40", "Vaillant", "Vaillant", "ecoTEC exclusive 838", "", "", "2007", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "30.0", "30.0", "", "", "89.3", "80.7", "", "56.7", "", "2", "1", "", "104", "1", "2", "110", "6", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "92.0", "98.7", "", "", "", "", "97.5"]} +{"pcdb_id": 15516, "brand_name": "Vaillant", "model_name": "ecoTEC exclusive 832", "model_qualifier": "", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 56.0, "output_kw_max": 27.0, "final_year_of_manufacture": 2016, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015516", "000031", "0", "2015/Sep/21 14:23", "Vaillant", "Vaillant", "ecoTEC exclusive 832", "", "47-044-37", "2007", "2016", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "27.0", "27.0", "", "", "88.2", "79.6", "", "56.0", "", "2", "", "", "104", "1", "2", "95", "6", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0045", "", "", "", "", "", "", "", "", "90.0", "96.5", "", "", "", "", "95.3"]} +{"pcdb_id": 15517, "brand_name": "Vaillant", "model_name": "ecoTEC exclusive 832", "model_qualifier": "", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 80.6, "comparative_hot_water_efficiency_pct": 56.7, "output_kw_max": 27.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015517", "000031", "0", "2009/Oct/28 09:39", "Vaillant", "Vaillant", "ecoTEC exclusive 832", "", "", "2007", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "27.0", "27.0", "", "", "89.2", "80.6", "", "56.7", "", "2", "1", "", "104", "1", "2", "95", "6", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "92.0", "98.6", "", "", "", "", "97.4"]} +{"pcdb_id": 15518, "brand_name": "Alpha", "model_name": "CD25X", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 55.8, "output_kw_max": 18.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015518", "000001", "0", "2010/Sep/29 11:40", "Alpha Therm", "Alpha", "CD25X", "", "", "2007", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "18.4", "18.4", "", "", "88.0", "79.4", "", "55.8", "", "2", "", "", "104", "1", "2", "125", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "96.9", "", "", "", "", "95.2"]} +{"pcdb_id": 15519, "brand_name": "Alpha", "model_name": "CD25X", "model_qualifier": "", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.4, "comparative_hot_water_efficiency_pct": 56.6, "output_kw_max": 18.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015519", "000001", "0", "2007/Oct/29 08:12", "Alpha Therm", "Alpha", "CD25X", "", "", "2007", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "18.4", "18.4", "", "", "89.0", "80.4", "", "56.6", "", "2", "1", "", "104", "1", "2", "125", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.9", "99.0", "", "", "", "", "97.3"]} +{"pcdb_id": 15520, "brand_name": "Alpha", "model_name": "CD28X", "model_qualifier": "", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 55.8, "output_kw_max": 24.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015520", "000001", "0", "2010/Sep/29 11:40", "Alpha Therm", "Alpha", "CD28X", "", "", "2007", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "87.9", "79.3", "", "55.8", "", "2", "", "", "104", "1", "2", "125", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "96.7", "", "", "", "", "95.0"]} +{"pcdb_id": 15521, "brand_name": "Alpha", "model_name": "CD28X", "model_qualifier": "", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 56.5, "output_kw_max": 24.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015521", "000001", "0", "2007/Oct/29 08:13", "Alpha Therm", "Alpha", "CD28X", "", "", "2007", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "88.9", "80.3", "", "56.5", "", "2", "1", "", "104", "1", "2", "125", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.9", "98.8", "", "", "", "", "97.1"]} +{"pcdb_id": 15522, "brand_name": "Warmflow", "model_name": "Boilerhouse", "model_qualifier": "B1", "winter_efficiency_pct": 86.6, "summer_efficiency_pct": 74.9, "comparative_hot_water_efficiency_pct": 54.7, "output_kw_max": 26.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015522", "000063", "0", "2012/Mar/27 10:12", "Warmflow Engineering", "Warmflow", "Boilerhouse", "B1", "", "2007", "current", "4", "1", "1", "1", "0", "", "", "1", "3", "2", "15", "26", "", "", "86.6", "74.9", "", "54.7", "", "2", "", "", "201", "1", "1", "160", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.0", "88.5", "", "", "", "", "88.0"]} +{"pcdb_id": 15523, "brand_name": "Warmflow", "model_name": "Utility", "model_qualifier": "UP90", "winter_efficiency_pct": 86.6, "summer_efficiency_pct": 74.9, "comparative_hot_water_efficiency_pct": 54.7, "output_kw_max": 26.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015523", "000063", "0", "2012/Mar/27 10:12", "Warmflow Engineering", "Warmflow", "Utility", "UP90", "", "2007", "current", "4", "1", "1", "1", "0", "", "", "1", "3", "2", "21", "26", "", "", "86.6", "74.9", "", "54.7", "", "2", "", "", "201", "1", "1", "230", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.0", "88.5", "", "", "", "", "88.0"]} +{"pcdb_id": 15524, "brand_name": "Warmflow", "model_name": "Kabin Pak", "model_qualifier": "K90", "winter_efficiency_pct": 86.6, "summer_efficiency_pct": 74.9, "comparative_hot_water_efficiency_pct": 54.7, "output_kw_max": 26.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015524", "000063", "0", "2012/Mar/27 10:12", "Warmflow Engineering", "Warmflow", "Kabin Pak", "K90", "", "2007", "current", "4", "1", "2", "1", "0", "", "", "1", "1", "2", "21", "26", "", "", "86.6", "74.9", "", "54.7", "", "2", "", "", "201", "1", "1", "160", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.0", "88.5", "", "", "", "", "88.0"]} +{"pcdb_id": 15525, "brand_name": "Warmflow", "model_name": "Utility", "model_qualifier": "UC90", "winter_efficiency_pct": 84.7, "summer_efficiency_pct": 76.6, "comparative_hot_water_efficiency_pct": 38.7, "output_kw_max": 26.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 1, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015525", "000063", "0", "2024/Jan/31 10:17", "Warmflow Engineering", "Warmflow", "Utility", "UC90", "", "2007", "current", "4", "1", "1", "2", "0", "", "", "1", "3", "2", "21", "26", "", "", "84.7", "76.6", "", "38.7", "", "2", "", "", "203", "1", "1", "255", "0", "1", "1", "0", "70", "0", "25", "6", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.0", "88.5", "", "", "", "", "88.0"]} +{"pcdb_id": 15527, "brand_name": "Warmflow", "model_name": "Kabin Pak", "model_qualifier": "KP90", "winter_efficiency_pct": 86.6, "summer_efficiency_pct": 74.9, "comparative_hot_water_efficiency_pct": 54.7, "output_kw_max": 26.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015527", "000063", "0", "2012/Mar/27 10:12", "Warmflow Engineering", "Warmflow", "Kabin Pak", "KP90", "", "2007", "current", "4", "1", "2", "1", "0", "", "", "1", "1", "2", "21", "26", "", "", "86.6", "74.9", "", "54.7", "", "2", "", "", "201", "1", "1", "230", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.0", "88.5", "", "", "", "", "88.0"]} +{"pcdb_id": 15528, "brand_name": "Warmflow", "model_name": "Kabin Pak", "model_qualifier": "KC90", "winter_efficiency_pct": 84.7, "summer_efficiency_pct": 76.6, "comparative_hot_water_efficiency_pct": 38.7, "output_kw_max": 26.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 1, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015528", "000063", "0", "2024/Jan/31 10:17", "Warmflow Engineering", "Warmflow", "Kabin Pak", "KC90", "", "2007", "current", "4", "1", "2", "2", "0", "", "", "1", "1", "2", "21", "26", "", "", "84.7", "76.6", "", "38.7", "", "2", "", "", "203", "1", "1", "255", "0", "1", "1", "0", "70", "0", "25", "6", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "86.0", "88.5", "", "", "", "", "88.0"]} +{"pcdb_id": 15529, "brand_name": "Warmflow", "model_name": "Utility", "model_qualifier": "UP70HE", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 21.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015529", "000063", "0", "2018/Jan/22 14:00", "Warmflow Engineering", "Warmflow", "Utility", "UP70HE", "", "2007", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "15", "21", "", "", "87.9", "80.1", "", "58.5", "", "2", "", "", "201", "1", "1", "230", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "89.5", "95.0", "", "", "", "", "94.0"]} +{"pcdb_id": 15530, "brand_name": "Warmflow", "model_name": "Utility", "model_qualifier": "UP90HE", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 26.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015530", "000063", "0", "2013/Mar/28 08:27", "Warmflow Engineering", "Warmflow", "Utility", "UP90HE", "", "2007", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "21", "26", "", "", "88.0", "80.2", "", "58.6", "", "2", "", "", "201", "1", "1", "230", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.8", "94.8", "", "", "", "", "94.1"]} +{"pcdb_id": 15531, "brand_name": "Warmflow", "model_name": "Kabin Pak", "model_qualifier": "KP70HE", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 21.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015531", "000063", "0", "2013/Mar/28 08:27", "Warmflow Engineering", "Warmflow", "Kabin Pak", "KP70HE", "", "2007", "current", "4", "1", "2", "1", "0", "", "", "2", "1", "2", "15", "21", "", "", "87.9", "80.1", "", "58.5", "", "2", "", "", "201", "1", "1", "230", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "89.5", "95.0", "", "", "", "", "94.0"]} +{"pcdb_id": 15532, "brand_name": "Warmflow", "model_name": "Kabin Pak", "model_qualifier": "KP90HE", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 26.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015532", "000063", "0", "2013/Mar/28 08:27", "Warmflow Engineering", "Warmflow", "Kabin Pak", "KP90HE", "", "2007", "current", "4", "1", "2", "1", "0", "", "", "2", "1", "2", "21", "26", "", "", "88.0", "80.2", "", "58.6", "", "2", "", "", "201", "1", "1", "230", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.8", "94.8", "", "", "", "", "94.1"]} +{"pcdb_id": 15533, "brand_name": "Warmflow", "model_name": "Utility", "model_qualifier": "UC90HE", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 81.9, "comparative_hot_water_efficiency_pct": 41.4, "output_kw_max": 26.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 1, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015533", "000063", "0", "2024/Jan/31 10:17", "Warmflow Engineering", "Warmflow", "Utility", "UC90HE", "", "2007", "current", "4", "1", "1", "2", "0", "", "", "2", "3", "2", "21", "26", "", "", "88.0", "81.9", "", "41.4", "", "2", "", "", "203", "1", "1", "255", "0", "1", "1", "0", "70", "0", "25", "6", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.8", "94.8", "", "", "", "", "94.1"]} +{"pcdb_id": 15534, "brand_name": "Warmflow", "model_name": "Kabin Pak", "model_qualifier": "KC90HE", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 81.9, "comparative_hot_water_efficiency_pct": 41.4, "output_kw_max": 26.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 1, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015534", "000063", "0", "2024/Jan/31 10:17", "Warmflow Engineering", "Warmflow", "Kabin Pak", "KC90HE", "", "2007", "current", "4", "1", "2", "2", "0", "", "", "2", "1", "2", "21", "26", "", "", "88.0", "81.9", "", "41.4", "", "2", "", "", "203", "1", "1", "255", "0", "1", "1", "0", "70", "0", "25", "6", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.8", "94.8", "", "", "", "", "94.1"]} +{"pcdb_id": 15535, "brand_name": "Warmflow", "model_name": "Kabin Pak", "model_qualifier": "K70HE", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 21.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015535", "000063", "0", "2013/Mar/28 08:28", "Warmflow Engineering", "Warmflow", "Kabin Pak", "K70HE", "", "2007", "current", "4", "1", "2", "1", "0", "", "", "2", "1", "2", "15", "21", "", "", "87.9", "80.1", "", "58.5", "", "2", "", "", "201", "1", "1", "160", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "89.5", "95.0", "", "", "", "", "94.0"]} +{"pcdb_id": 15536, "brand_name": "Warmflow", "model_name": "Kabin Pak", "model_qualifier": "K90HE", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 26.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015536", "000063", "0", "2013/Mar/28 08:28", "Warmflow Engineering", "Warmflow", "Kabin Pak", "K90HE", "", "2007", "current", "4", "1", "2", "1", "0", "", "", "2", "1", "2", "21", "26", "", "", "88.0", "80.2", "", "58.6", "", "2", "", "", "201", "1", "1", "160", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.8", "94.8", "", "", "", "", "94.1"]} +{"pcdb_id": 15537, "brand_name": "Warmflow", "model_name": "Kabin Pak", "model_qualifier": "K120HE", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 33.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015537", "000063", "0", "2013/Mar/28 08:28", "Warmflow Engineering", "Warmflow", "Kabin Pak", "K120HE", "", "2007", "current", "4", "1", "2", "1", "0", "", "", "2", "1", "2", "26", "33", "", "", "87.9", "80.1", "", "58.5", "", "2", "", "", "201", "1", "1", "160", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.1", "94.7", "", "", "", "", "93.9"]} +{"pcdb_id": 15538, "brand_name": "Radiant", "model_name": "RH 25", "model_qualifier": "", "winter_efficiency_pct": 85.2, "summer_efficiency_pct": 76.2, "comparative_hot_water_efficiency_pct": 55.7, "output_kw_max": 25.51, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015538", "000088", "0", "2012/Mar/27 10:12", "Radiant Bruciatori SpA", "Radiant", "RH 25", "", "", "2007", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "25.51", "25.51", "", "", "85.2", "76.2", "", "55.7", "", "2", "", "", "102", "1", "2", "210", "5.4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "85.8", "90.8", "", "", "", "", "89.9"]} +{"pcdb_id": 15539, "brand_name": "Radiant", "model_name": "RH 25/B", "model_qualifier": "", "winter_efficiency_pct": 85.2, "summer_efficiency_pct": 76.2, "comparative_hot_water_efficiency_pct": 55.7, "output_kw_max": 25.51, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015539", "000088", "0", "2012/Mar/27 10:12", "Radiant Bruciatori SpA", "Radiant", "RH 25/B", "", "", "2007", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "25.51", "25.51", "", "", "85.2", "76.2", "", "55.7", "", "2", "", "", "102", "1", "2", "210", "5.4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "85.8", "90.8", "", "", "", "", "89.9"]} +{"pcdb_id": 15540, "brand_name": "Radiant", "model_name": "RHA 25", "model_qualifier": "", "winter_efficiency_pct": 85.2, "summer_efficiency_pct": 78.0, "comparative_hot_water_efficiency_pct": 43.6, "output_kw_max": 25.51, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015540", "000088", "0", "2024/Jan/31 10:17", "Radiant Bruciatori SpA", "Radiant", "RHA 25", "", "", "2007", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "25.51", "25.51", "", "", "85.2", "78.0", "", "43.6", "", "2", "", "", "106", "1", "2", "210", "5.4", "2", "2", "0", "20", "0", "13", "2", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "85.8", "90.8", "", "", "", "", "89.9"]} +{"pcdb_id": 15541, "brand_name": "Radiant", "model_name": "RHA 25/100", "model_qualifier": "", "winter_efficiency_pct": 85.2, "summer_efficiency_pct": 78.5, "comparative_hot_water_efficiency_pct": 35.4, "output_kw_max": 25.51, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015541", "000088", "0", "2024/Jan/31 10:17", "Radiant Bruciatori SpA", "Radiant", "RHA 25/100", "", "", "2007", "current", "1", "1", "1", "2", "0", "", "", "2", "2", "2", "25.51", "25.51", "", "", "85.2", "78.5", "", "35.4", "", "2", "", "", "106", "1", "2", "210", "5.4", "2", "2", "0", "105", "0", "15", "2", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "85.8", "90.8", "", "", "", "", "89.9"]} +{"pcdb_id": 15542, "brand_name": "Radiant", "model_name": "RKR 34", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 56.0, "output_kw_max": 33.42, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015542", "000088", "0", "2007/Aug/28 15:20", "Radiant Bruciatori SpA", "Radiant", "RKR 34", "", "", "2007", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "33.42", "33.42", "", "", "88.3", "79.7", "", "56.0", "", "2", "", "", "104", "1", "2", "180", "5.4", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.6", "97.2", "", "", "", "", "95.6"]} +{"pcdb_id": 15543, "brand_name": "Radiant", "model_name": "RKA 34/100", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 81.5, "comparative_hot_water_efficiency_pct": 36.8, "output_kw_max": 33.42, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015543", "000088", "0", "2024/Jan/31 10:17", "Radiant Bruciatori SpA", "Radiant", "RKA 34/100", "", "", "2007", "current", "1", "1", "1", "2", "0", "", "", "2", "2", "2", "33.42", "33.42", "", "", "88.3", "81.5", "", "36.8", "", "2", "", "", "106", "1", "2", "180", "5.4", "2", "2", "0", "105", "0", "15", "2", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.6", "97.2", "", "", "", "", "95.6"]} +{"pcdb_id": 15544, "brand_name": "Radiant", "model_name": "RKA 34", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 81.1, "comparative_hot_water_efficiency_pct": 46.6, "output_kw_max": 33.42, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015544", "000088", "0", "2024/Jan/31 10:17", "Radiant Bruciatori SpA", "Radiant", "RKA 34", "", "", "2007", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "33.42", "33.42", "", "", "88.3", "81.1", "", "46.6", "", "2", "", "", "106", "1", "2", "180", "5.4", "2", "2", "0", "20", "0", "15", "2", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.6", "97.2", "", "", "", "", "95.6"]} +{"pcdb_id": 15545, "brand_name": "Radiant", "model_name": "RK 34/B", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 33.42, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015545", "000088", "0", "2012/Mar/27 10:12", "Radiant Bruciatori SpA", "Radiant", "RK 34/B", "", "", "2007", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "33.42", "33.42", "", "", "88.3", "79.3", "", "57.9", "", "2", "", "", "102", "1", "2", "180", "5.4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.6", "97.2", "", "", "", "", "95.6"]} +{"pcdb_id": 15546, "brand_name": "Radiant", "model_name": "RK 34", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 33.42, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015546", "000088", "0", "2012/Mar/27 10:12", "Radiant Bruciatori SpA", "Radiant", "RK 34", "", "", "2007", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "33.42", "33.42", "", "", "88.3", "79.3", "", "57.9", "", "2", "", "", "102", "1", "2", "180", "5.4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.6", "97.2", "", "", "", "", "95.6"]} +{"pcdb_id": 15547, "brand_name": "Radiant", "model_name": "RKA 29/100", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 81.4, "comparative_hot_water_efficiency_pct": 36.7, "output_kw_max": 29.43, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015547", "000088", "0", "2024/Jan/31 10:17", "Radiant Bruciatori SpA", "Radiant", "RKA 29/100", "", "", "2007", "current", "1", "1", "1", "2", "0", "", "", "2", "2", "2", "29.43", "29.43", "", "", "88.1", "81.4", "", "36.7", "", "2", "", "", "106", "1", "2", "180", "5.4", "2", "2", "0", "105", "0", "15", "2", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.4", "96.9", "", "", "", "", "95.3"]} +{"pcdb_id": 15548, "brand_name": "Radiant", "model_name": "RKA 29", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 80.9, "comparative_hot_water_efficiency_pct": 46.6, "output_kw_max": 29.43, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015548", "000088", "0", "2024/Jan/31 10:17", "Radiant Bruciatori SpA", "Radiant", "RKA 29", "", "", "2007", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "29.43", "29.43", "", "", "88.1", "80.9", "", "46.6", "", "2", "", "", "106", "1", "2", "180", "5.4", "2", "2", "0", "20", "0", "15", "2", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.4", "96.9", "", "", "", "", "95.3"]} +{"pcdb_id": 15549, "brand_name": "Radiant", "model_name": "RK 29/B", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 29.43, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015549", "000088", "0", "2012/Mar/27 10:12", "Radiant Bruciatori SpA", "Radiant", "RK 29/B", "", "", "2007", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "29.43", "29.43", "", "", "88.1", "79.1", "", "57.8", "", "2", "", "", "102", "1", "2", "180", "5.4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.4", "96.9", "", "", "", "", "95.3"]} +{"pcdb_id": 15550, "brand_name": "Radiant", "model_name": "RK 29", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 29.43, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015550", "000088", "0", "2012/Mar/27 10:12", "Radiant Bruciatori SpA", "Radiant", "RK 29", "", "", "2007", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "29.43", "29.43", "", "", "88.1", "79.1", "", "57.8", "", "2", "", "", "102", "1", "2", "180", "5.4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.4", "96.9", "", "", "", "", "95.3"]} +{"pcdb_id": 15551, "brand_name": "Radiant", "model_name": "RHR 34", "model_qualifier": "", "winter_efficiency_pct": 84.9, "summer_efficiency_pct": 76.3, "comparative_hot_water_efficiency_pct": 53.7, "output_kw_max": 32.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015551", "000088", "0", "2007/Aug/28 15:24", "Radiant Bruciatori SpA", "Radiant", "RHR 34", "", "", "2007", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "32.50", "32.50", "", "", "84.9", "76.3", "", "53.7", "", "2", "", "", "104", "1", "2", "175", "5.4", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.4", "89.2", "", "", "", "", "88.9"]} +{"pcdb_id": 15552, "brand_name": "Radiant", "model_name": "RHA 34/100", "model_qualifier": "", "winter_efficiency_pct": 84.9, "summer_efficiency_pct": 78.2, "comparative_hot_water_efficiency_pct": 35.3, "output_kw_max": 32.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015552", "000088", "0", "2024/Jan/31 10:17", "Radiant Bruciatori SpA", "Radiant", "RHA 34/100", "", "", "2007", "current", "1", "1", "1", "2", "0", "", "", "2", "2", "2", "32.50", "32.50", "", "", "84.9", "78.2", "", "35.3", "", "2", "", "", "106", "1", "2", "175", "5.4", "2", "2", "0", "105", "0", "15", "2", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.4", "89.2", "", "", "", "", "88.9"]} +{"pcdb_id": 15553, "brand_name": "Radiant", "model_name": "RHA 34", "model_qualifier": "", "winter_efficiency_pct": 84.9, "summer_efficiency_pct": 77.7, "comparative_hot_water_efficiency_pct": 44.7, "output_kw_max": 32.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015553", "000088", "0", "2024/Jan/31 10:17", "Radiant Bruciatori SpA", "Radiant", "RHA 34", "", "", "2007", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "32.50", "32.50", "", "", "84.9", "77.7", "", "44.7", "", "2", "", "", "106", "1", "2", "175", "5.4", "2", "2", "0", "20", "0", "15", "2", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.4", "89.2", "", "", "", "", "88.9"]} +{"pcdb_id": 15554, "brand_name": "Radiant", "model_name": "RH 34/B", "model_qualifier": "", "winter_efficiency_pct": 84.9, "summer_efficiency_pct": 75.9, "comparative_hot_water_efficiency_pct": 55.5, "output_kw_max": 32.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015554", "000088", "0", "2012/Mar/27 10:12", "Radiant Bruciatori SpA", "Radiant", "RH 34/B", "", "", "2007", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "32.50", "32.50", "", "", "84.9", "75.9", "", "55.5", "", "2", "", "", "102", "1", "2", "175", "5.4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.4", "89.2", "", "", "", "", "88.9"]} +{"pcdb_id": 15555, "brand_name": "Radiant", "model_name": "RH 34", "model_qualifier": "", "winter_efficiency_pct": 84.9, "summer_efficiency_pct": 75.9, "comparative_hot_water_efficiency_pct": 55.5, "output_kw_max": 32.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015555", "000088", "0", "2012/Mar/27 10:12", "Radiant Bruciatori SpA", "Radiant", "RH 34", "", "", "2007", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "32.50", "32.50", "", "", "84.9", "75.9", "", "55.5", "", "2", "", "", "102", "1", "2", "175", "5.4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.4", "89.2", "", "", "", "", "88.9"]} +{"pcdb_id": 15556, "brand_name": "Radiant", "model_name": "RHA 29/100", "model_qualifier": "", "winter_efficiency_pct": 84.9, "summer_efficiency_pct": 78.2, "comparative_hot_water_efficiency_pct": 35.3, "output_kw_max": 29.01, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015556", "000088", "0", "2024/Jan/31 10:17", "Radiant Bruciatori SpA", "Radiant", "RHA 29/100", "", "", "2007", "current", "1", "1", "1", "2", "0", "", "", "2", "2", "2", "29.01", "29.01", "", "", "84.9", "78.2", "", "35.3", "", "2", "", "", "106", "1", "2", "175", "5.4", "2", "2", "0", "105", "0", "15", "2", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.1", "89.3", "", "", "", "", "88.9"]} +{"pcdb_id": 15557, "brand_name": "Radiant", "model_name": "RHA 29", "model_qualifier": "", "winter_efficiency_pct": 84.9, "summer_efficiency_pct": 77.7, "comparative_hot_water_efficiency_pct": 44.7, "output_kw_max": 29.01, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015557", "000088", "0", "2024/Jan/31 10:17", "Radiant Bruciatori SpA", "Radiant", "RHA 29", "", "", "2007", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "29.01", "29.01", "", "", "84.9", "77.7", "", "44.7", "", "2", "", "", "106", "1", "2", "175", "5.4", "2", "2", "0", "20", "0", "15", "2", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.1", "89.3", "", "", "", "", "88.9"]} +{"pcdb_id": 15558, "brand_name": "Radiant", "model_name": "RH 29/B", "model_qualifier": "", "winter_efficiency_pct": 84.9, "summer_efficiency_pct": 75.9, "comparative_hot_water_efficiency_pct": 55.4, "output_kw_max": 29.01, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015558", "000088", "0", "2012/Mar/27 10:12", "Radiant Bruciatori SpA", "Radiant", "RH 29/B", "", "", "2007", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "29.01", "29.01", "", "", "84.9", "75.9", "", "55.4", "", "2", "", "", "102", "1", "2", "175", "5.4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.1", "89.3", "", "", "", "", "88.9"]} +{"pcdb_id": 15559, "brand_name": "Radiant", "model_name": "RH 29", "model_qualifier": "", "winter_efficiency_pct": 84.9, "summer_efficiency_pct": 75.9, "comparative_hot_water_efficiency_pct": 55.4, "output_kw_max": 29.01, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015559", "000088", "0", "2012/Mar/27 10:12", "Radiant Bruciatori SpA", "Radiant", "RH 29", "", "", "2007", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "29.01", "29.01", "", "", "84.9", "75.9", "", "55.4", "", "2", "", "", "102", "1", "2", "175", "5.4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.1", "89.3", "", "", "", "", "88.9"]} +{"pcdb_id": 15560, "brand_name": "Radiant", "model_name": "RKR 29", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 55.9, "output_kw_max": 29.43, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015560", "000088", "0", "2007/Sep/14 10:41", "Radiant Bruciatori SpA", "Radiant", "RKR 29", "", "", "2007", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "29.43", "29.43", "", "", "88.1", "79.5", "", "55.9", "", "2", "", "", "104", "1", "2", "180", "5.4", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.4", "96.9", "", "", "", "", "95.3"]} +{"pcdb_id": 15562, "brand_name": "Radiant", "model_name": "RHR 29", "model_qualifier": "", "winter_efficiency_pct": 84.9, "summer_efficiency_pct": 76.3, "comparative_hot_water_efficiency_pct": 53.7, "output_kw_max": 29.01, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015562", "000088", "0", "2007/Sep/14 10:42", "Radiant Bruciatori SpA", "Radiant", "RHR 29", "", "", "2007", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "29.01", "29.01", "", "", "84.9", "76.3", "", "53.7", "", "2", "", "", "104", "1", "2", "175", "5.4", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.1", "89.3", "", "", "", "", "88.9"]} +{"pcdb_id": 15563, "brand_name": "Radiant", "model_name": "RHR 25", "model_qualifier": "", "winter_efficiency_pct": 85.2, "summer_efficiency_pct": 76.6, "comparative_hot_water_efficiency_pct": 53.9, "output_kw_max": 25.51, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015563", "000088", "0", "2007/Aug/28 15:28", "Radiant Bruciatori SpA", "Radiant", "RHR 25", "", "", "2007", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "25.51", "25.51", "", "", "85.2", "76.6", "", "53.9", "", "2", "", "", "104", "1", "2", "210", "5.4", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "85.8", "90.8", "", "", "", "", "89.9"]} +{"pcdb_id": 15564, "brand_name": "Radiant", "model_name": "RKA 25/100", "model_qualifier": "", "winter_efficiency_pct": 87.7, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 36.5, "output_kw_max": 24.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015564", "000088", "0", "2024/Jan/31 10:17", "Radiant Bruciatori SpA", "Radiant", "RKA 25/100", "", "", "2007", "current", "1", "1", "1", "2", "0", "", "", "2", "2", "2", "24.60", "24.60", "", "", "87.7", "81.0", "", "36.5", "", "2", "", "", "106", "1", "2", "170", "5.4", "2", "2", "0", "105", "0", "15", "2", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.7", "95.8", "", "", "", "", "94.4"]} +{"pcdb_id": 15565, "brand_name": "Gerkros", "model_name": "50 70 Oil Condensing Boiler", "model_qualifier": "Cosyman", "winter_efficiency_pct": 87.0, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 20.69, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015565", "000245", "0", "2012/Mar/27 10:12", "Gerkros Boilers (Tipperary) Limited", "Gerkros", "50 70 Oil Condensing Boiler", "Cosyman", "", "2007", "current", "4", "1", "2", "1", "0", "", "", "2", "3", "1", "14.65", "20.69", "", "", "87.0", "79.2", "", "57.9", "", "2", "", "", "201", "1", "1", "250", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "89.4", "93.0", "", "", "", "", "92.3"]} +{"pcdb_id": 15567, "brand_name": "Gerkros", "model_name": "50 70 Oil Condensing Boiler", "model_qualifier": "Boiler House Model", "winter_efficiency_pct": 87.0, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 20.69, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015567", "000245", "0", "2012/Mar/27 10:12", "Gerkros Boilers (Tipperary) Limited", "Gerkros", "50 70 Oil Condensing Boiler", "Boiler House Model", "", "2007", "current", "4", "1", "2", "1", "0", "", "", "2", "3", "1", "14.65", "20.69", "", "", "87.0", "79.2", "", "57.9", "", "2", "", "", "201", "1", "1", "250", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "89.4", "93.0", "", "", "", "", "92.3"]} +{"pcdb_id": 15569, "brand_name": "Gerkros", "model_name": "70 90 Oil Condensing Boiler", "model_qualifier": "Cosyman", "winter_efficiency_pct": 87.3, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 27.06, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015569", "000245", "0", "2012/Mar/27 10:12", "Gerkros Boilers (Tipperary) Limited", "Gerkros", "70 90 Oil Condensing Boiler", "Cosyman", "", "2007", "current", "4", "1", "2", "1", "0", "", "", "2", "3", "1", "20.69", "27.06", "", "", "87.3", "79.5", "", "58.1", "", "2", "", "", "201", "1", "1", "250", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "89.7", "93.5", "", "", "", "", "92.8"]} +{"pcdb_id": 15570, "brand_name": "Gerkros", "model_name": "70 90 Oil Condensing Boiler", "model_qualifier": "Boiler House Model", "winter_efficiency_pct": 87.3, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 27.06, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015570", "000245", "0", "2012/Mar/27 10:12", "Gerkros Boilers (Tipperary) Limited", "Gerkros", "70 90 Oil Condensing Boiler", "Boiler House Model", "", "2007", "current", "4", "1", "2", "1", "0", "", "", "2", "3", "1", "20.69", "27.06", "", "", "87.3", "79.5", "", "58.1", "", "2", "", "", "201", "1", "1", "250", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "89.7", "93.5", "", "", "", "", "92.8"]} +{"pcdb_id": 15572, "brand_name": "Gerkros", "model_name": "90 120 Oil Condensing Boiler", "model_qualifier": "Cosyman", "winter_efficiency_pct": 87.1, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 35.67, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015572", "000245", "0", "2012/Mar/27 10:12", "Gerkros Boilers (Tipperary) Limited", "Gerkros", "90 120 Oil Condensing Boiler", "Cosyman", "", "2007", "current", "4", "1", "2", "1", "0", "", "", "2", "3", "1", "27.06", "35.67", "", "", "87.1", "79.3", "", "57.9", "", "2", "", "", "201", "1", "1", "250", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.0", "92.8", "", "", "", "", "92.2"]} +{"pcdb_id": 15573, "brand_name": "Gerkros", "model_name": "90 120 Oil Condensing Boiler", "model_qualifier": "Boiler House Model", "winter_efficiency_pct": 87.1, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 35.67, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015573", "000245", "0", "2012/Mar/27 10:12", "Gerkros Boilers (Tipperary) Limited", "Gerkros", "90 120 Oil Condensing Boiler", "Boiler House Model", "", "2007", "current", "4", "1", "2", "1", "0", "", "", "2", "3", "1", "27.06", "35.67", "", "", "87.1", "79.3", "", "57.9", "", "2", "", "", "201", "1", "1", "250", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.0", "92.8", "", "", "", "", "92.2"]} +{"pcdb_id": 15574, "brand_name": "Sabre", "model_name": "25HE Plus", "model_qualifier": "", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 55.8, "output_kw_max": 24.7, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015574", "000011", "0", "2007/Aug/21 15:33", "Vokera", "Sabre", "25HE Plus", "", "47-094-92", "2007", "current", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "24.7", "24.7", "", "", "87.9", "79.3", "", "55.8", "", "2", "", "", "104", "1", "2", "174", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.0", "96.2", "", "", "", "", "94.9"]} +{"pcdb_id": 15575, "brand_name": "Sabre", "model_name": "29HE Plus", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 56.0, "output_kw_max": 28.77, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015575", "000011", "0", "2007/Aug/21 15:33", "Vokera", "Sabre", "29HE Plus", "", "47-094-093", "2007", "current", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "28.77", "28.77", "", "", "88.3", "79.7", "", "56.0", "", "2", "", "", "104", "1", "2", "170", "0", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.4", "96.9", "", "", "", "", "95.4"]} +{"pcdb_id": 15576, "brand_name": "Pro", "model_name": "Pro-Combi", "model_qualifier": "120HE", "winter_efficiency_pct": 85.0, "summer_efficiency_pct": 76.4, "comparative_hot_water_efficiency_pct": 53.7, "output_kw_max": 33.93, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015576", "000247", "0", "2007/Aug/21 15:30", "Vokera", "Pro", "Pro-Combi", "120HE", "47-094-94", "2007", "current", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "14.04", "33.93", "", "", "85.0", "76.4", "", "53.7", "", "2", "", "", "104", "1", "2", "153", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "89.1", "", "", "", "", "88.9"]} +{"pcdb_id": 15577, "brand_name": "Vokera", "model_name": "Mynute", "model_qualifier": "20VHE", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 19.68, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015577", "000011", "0", "2012/Mar/27 10:12", "Vokera", "Vokera", "Mynute", "20VHE", "41-094-70", "2007", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "19.68", "19.68", "", "", "88.1", "79.1", "", "57.8", "", "2", "", "", "102", "1", "2", "150", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.7", "96.9", "", "", "", "", "95.3"]} +{"pcdb_id": 15578, "brand_name": "Vokera", "model_name": "Linea", "model_qualifier": "36HE", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 56.1, "output_kw_max": 33.7, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015578", "000011", "0", "2007/Oct/29 08:14", "Vokera", "Vokera", "Linea", "36HE", "47-094-91", "2007", "current", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "33.70", "33.70", "", "", "88.4", "79.8", "", "56.1", "", "2", "", "", "104", "1", "2", "175", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "97.8", "", "", "", "", "95.9"]} +{"pcdb_id": 15579, "brand_name": "Vokera", "model_name": "Linea", "model_qualifier": "32HE", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 56.2, "output_kw_max": 29.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015579", "000011", "0", "2007/Oct/29 08:14", "Vokera", "Vokera", "Linea", "32HE", "47-094-90", "2007", "current", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "29.40", "29.40", "", "", "88.6", "80.0", "", "56.2", "", "2", "", "", "104", "1", "2", "130", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.4", "98.1", "", "", "", "", "96.3"]} +{"pcdb_id": 15580, "brand_name": "Vokera", "model_name": "Linea", "model_qualifier": "28HE", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 55.8, "output_kw_max": 24.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015580", "000011", "0", "2007/Oct/29 08:14", "Vokera", "Vokera", "Linea", "28HE", "47-094-89", "2007", "current", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "24.40", "24.40", "", "", "87.9", "79.3", "", "55.8", "", "2", "", "", "104", "1", "2", "130", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "96.5", "", "", "", "", "94.9"]} +{"pcdb_id": 15581, "brand_name": "Trianco", "model_name": "Contractor HE External", "model_qualifier": "50/90", "winter_efficiency_pct": 85.0, "summer_efficiency_pct": 77.2, "comparative_hot_water_efficiency_pct": 56.4, "output_kw_max": 26.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015581", "000062", "0", "2012/Mar/27 10:12", "Trianco", "Trianco", "Contractor HE External", "50/90", "2375", "2006", "current", "4", "1", "2", "1", "0", "", "", "2", "3", "2", "14.6", "26.4", "", "", "85.0", "77.2", "", "56.4", "", "2", "", "", "201", "1", "1", "148", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "87.1", "90.6", "", "", "", "", "89.9"]} +{"pcdb_id": 15582, "brand_name": "Trianco", "model_name": "Contractor HE System", "model_qualifier": "50/90", "winter_efficiency_pct": 85.2, "summer_efficiency_pct": 77.4, "comparative_hot_water_efficiency_pct": 56.6, "output_kw_max": 26.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015582", "000062", "0", "2012/Mar/27 10:12", "Trianco", "Trianco", "Contractor HE System", "50/90", "2371", "2007", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "14.6", "26.4", "", "", "85.2", "77.4", "", "56.6", "", "2", "", "", "201", "1", "1", "148", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "87.7", "90.6", "", "", "", "", "90.1"]} +{"pcdb_id": 15583, "brand_name": "Trianco", "model_name": "Contractor Trader HE", "model_qualifier": "50/90", "winter_efficiency_pct": 85.2, "summer_efficiency_pct": 77.4, "comparative_hot_water_efficiency_pct": 56.6, "output_kw_max": 26.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015583", "000062", "0", "2012/Mar/27 10:12", "Trianco", "Trianco", "Contractor Trader HE", "50/90", "2377", "2007", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "14.6", "26.4", "", "", "85.2", "77.4", "", "56.6", "", "2", "", "", "201", "1", "1", "148", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "87.7", "90.6", "", "", "", "", "90.1"]} +{"pcdb_id": 15584, "brand_name": "Trianco", "model_name": "Contractor HE", "model_qualifier": "50/90", "winter_efficiency_pct": 85.2, "summer_efficiency_pct": 77.4, "comparative_hot_water_efficiency_pct": 56.6, "output_kw_max": 26.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015584", "000062", "0", "2012/Mar/27 10:12", "Trianco", "Trianco", "Contractor HE", "50/90", "2370", "2007", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "14.6", "26.4", "", "", "85.2", "77.4", "", "56.6", "", "2", "", "", "201", "1", "1", "148", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "87.7", "90.6", "", "", "", "", "90.1"]} +{"pcdb_id": 15585, "brand_name": "Trianco", "model_name": "Iona", "model_qualifier": "HE 50/90", "winter_efficiency_pct": 85.2, "summer_efficiency_pct": 77.4, "comparative_hot_water_efficiency_pct": 56.6, "output_kw_max": 26.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015585", "000062", "0", "2012/Mar/27 10:12", "Trianco", "Trianco", "Iona", "HE 50/90", "", "2007", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "14.6", "26.4", "", "", "85.2", "77.4", "", "56.6", "", "2", "", "", "201", "1", "1", "148", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "87.7", "90.6", "", "", "", "", "90.1"]} +{"pcdb_id": 15586, "brand_name": "Sime", "model_name": "Ecomfort", "model_qualifier": "System 25 HE", "winter_efficiency_pct": 86.3, "summer_efficiency_pct": 77.3, "comparative_hot_water_efficiency_pct": 56.5, "output_kw_max": 24.7, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015586", "000213", "0", "2018/Feb/26 16:46", "Fonderie Sime S.p.A.", "Sime", "Ecomfort", "System 25 HE", "", "2007", "2018", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "24.7", "24.7", "", "", "86.3", "77.3", "", "56.5", "", "2", "", "", "102", "1", "2", "150", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.4", "92.8", "", "", "", "", "91.8"]} +{"pcdb_id": 15587, "brand_name": "Sime", "model_name": "Ecomfort", "model_qualifier": "System 25 HE", "winter_efficiency_pct": 87.3, "summer_efficiency_pct": 78.3, "comparative_hot_water_efficiency_pct": 57.2, "output_kw_max": 24.7, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015587", "000213", "0", "2018/Feb/26 16:46", "Fonderie Sime S.p.A.", "Sime", "Ecomfort", "System 25 HE", "", "2007", "2018", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "24.7", "24.7", "", "", "87.3", "78.3", "", "57.2", "", "2", "1", "", "102", "1", "2", "150", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.3", "94.9", "", "", "", "", "93.8"]} +{"pcdb_id": 15588, "brand_name": "Sime", "model_name": "Ecomfort", "model_qualifier": "35 HE", "winter_efficiency_pct": 85.8, "summer_efficiency_pct": 77.2, "comparative_hot_water_efficiency_pct": 54.3, "output_kw_max": 33.5, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015588", "000213", "0", "2018/Feb/26 16:41", "Fonderie Sime S.p.A.", "Sime", "Ecomfort", "35 HE", "", "2007", "2018", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "33.5", "33.5", "", "", "85.8", "77.2", "", "54.3", "", "2", "", "", "104", "1", "2", "160", "10", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.4", "91.5", "", "", "", "", "90.7"]} +{"pcdb_id": 15589, "brand_name": "Sime", "model_name": "Ecomfort", "model_qualifier": "35 HE", "winter_efficiency_pct": 86.8, "summer_efficiency_pct": 78.2, "comparative_hot_water_efficiency_pct": 55.0, "output_kw_max": 33.5, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015589", "000213", "0", "2018/Feb/26 16:42", "Fonderie Sime S.p.A.", "Sime", "Ecomfort", "35 HE", "", "2007", "2018", "2", "2", "1", "2", "0", "", "", "2", "3", "2", "33.5", "33.5", "", "", "86.8", "78.2", "", "55.0", "", "2", "1", "", "104", "1", "2", "160", "10", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.3", "93.5", "", "", "", "", "92.7"]} +{"pcdb_id": 15590, "brand_name": "Mistral Boilers", "model_name": "CKUT7 58/68", "model_qualifier": "", "winter_efficiency_pct": 87.6, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 68.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015590", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral Boilers", "CKUT7 58/68", "", "", "2007", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "58", "68", "", "", "87.6", "79.8", "", "58.3", "", "2", "", "", "201", "1", "1", "230", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.9", "93.8", "", "", "", "", "93.2"]} +{"pcdb_id": 15592, "brand_name": "Mistral Boilers", "model_name": "CKUT6 50/58", "model_qualifier": "", "winter_efficiency_pct": 87.6, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 58.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015592", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral Boilers", "CKUT6 50/58", "", "", "2007", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "50", "58", "", "", "87.6", "79.8", "", "58.3", "", "2", "", "", "201", "1", "1", "230", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.9", "93.8", "", "", "", "", "93.2"]} +{"pcdb_id": 15593, "brand_name": "Mistral Boilers", "model_name": "CKUT5 41/50", "model_qualifier": "", "winter_efficiency_pct": 87.6, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 50.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015593", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral Boilers", "CKUT5 41/50", "", "", "2007", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "41", "50", "", "", "87.6", "79.8", "", "58.3", "", "2", "", "", "201", "1", "1", "230", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.9", "93.8", "", "", "", "", "93.2"]} +{"pcdb_id": 15594, "brand_name": "Mistral Boilers", "model_name": "CMC7 58/68", "model_qualifier": "", "winter_efficiency_pct": 87.6, "summer_efficiency_pct": 81.5, "comparative_hot_water_efficiency_pct": 45.1, "output_kw_max": 68.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015594", "000056", "0", "2024/Jan/31 10:17", "Mistral Boilers", "Mistral Boilers", "CMC7 58/68", "", "", "2007", "current", "4", "1", "1", "2", "0", "", "", "2", "3", "2", "58", "68", "", "", "87.6", "81.5", "", "45.1", "", "2", "", "", "203", "1", "1", "230", "0", "2", "", "0", "120", "0", "30", "3", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.9", "93.8", "", "", "", "", "93.2"]} +{"pcdb_id": 15595, "brand_name": "Mistral Boilers", "model_name": "CMC6 50/58", "model_qualifier": "", "winter_efficiency_pct": 87.6, "summer_efficiency_pct": 81.5, "comparative_hot_water_efficiency_pct": 45.1, "output_kw_max": 58.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015595", "000056", "0", "2024/Jan/31 10:17", "Mistral Boilers", "Mistral Boilers", "CMC6 50/58", "", "", "2007", "current", "4", "1", "1", "2", "0", "", "", "2", "3", "2", "50", "58", "", "", "87.6", "81.5", "", "45.1", "", "2", "", "", "203", "1", "1", "230", "0", "2", "", "0", "120", "0", "30", "3", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.9", "93.8", "", "", "", "", "93.2"]} +{"pcdb_id": 15596, "brand_name": "Mistral Boilers", "model_name": "CMC5 41/50", "model_qualifier": "", "winter_efficiency_pct": 87.6, "summer_efficiency_pct": 81.5, "comparative_hot_water_efficiency_pct": 45.1, "output_kw_max": 50.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015596", "000056", "0", "2024/Jan/31 10:17", "Mistral Boilers", "Mistral Boilers", "CMC5 41/50", "", "", "2007", "current", "4", "1", "1", "2", "0", "", "", "2", "3", "2", "41", "50", "", "", "87.6", "81.5", "", "45.1", "", "2", "", "", "203", "1", "1", "230", "0", "2", "", "0", "120", "0", "30", "3", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.9", "93.8", "", "", "", "", "93.2"]} +{"pcdb_id": 15597, "brand_name": "Mistral Boilers", "model_name": "CBH6 50/58", "model_qualifier": "", "winter_efficiency_pct": 87.6, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 58.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015597", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral Boilers", "CBH6 50/58", "", "", "2007", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "50", "58", "", "", "87.6", "79.8", "", "58.3", "", "2", "", "", "201", "1", "1", "230", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.9", "93.8", "", "", "", "", "93.2"]} +{"pcdb_id": 15598, "brand_name": "Mistral Boilers", "model_name": "CBH7 58/68", "model_qualifier": "", "winter_efficiency_pct": 87.6, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 68.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015598", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral Boilers", "CBH7 58/68", "", "", "2007", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "58", "68", "", "", "87.6", "79.8", "", "58.3", "", "2", "", "", "201", "1", "1", "230", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.9", "93.8", "", "", "", "", "93.2"]} +{"pcdb_id": 15599, "brand_name": "Mistral Boilers", "model_name": "CBH5 41/50", "model_qualifier": "", "winter_efficiency_pct": 87.6, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 50.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015599", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral Boilers", "CBH5 41/50", "", "", "2007", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "41", "50", "", "", "87.6", "79.8", "", "58.3", "", "2", "", "", "201", "1", "1", "230", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.9", "93.8", "", "", "", "", "93.2"]} +{"pcdb_id": 15600, "brand_name": "Mistral Boilers", "model_name": "CODMC7 58/68", "model_qualifier": "", "winter_efficiency_pct": 87.6, "summer_efficiency_pct": 81.5, "comparative_hot_water_efficiency_pct": 45.1, "output_kw_max": 68.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015600", "000056", "0", "2024/Jan/31 10:17", "Mistral Boilers", "Mistral Boilers", "CODMC7 58/68", "", "", "2007", "current", "4", "1", "2", "2", "0", "", "", "2", "3", "2", "58", "68", "", "", "87.6", "81.5", "", "45.1", "", "2", "", "", "203", "1", "1", "230", "0", "2", "", "0", "120", "0", "30", "3", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.9", "93.8", "", "", "", "", "93.2"]} +{"pcdb_id": 15601, "brand_name": "Mistral Boilers", "model_name": "CODMC6 50/58", "model_qualifier": "", "winter_efficiency_pct": 87.6, "summer_efficiency_pct": 81.5, "comparative_hot_water_efficiency_pct": 45.1, "output_kw_max": 58.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015601", "000056", "0", "2024/Jan/31 10:17", "Mistral Boilers", "Mistral Boilers", "CODMC6 50/58", "", "", "2007", "current", "4", "1", "2", "2", "0", "", "", "2", "3", "2", "50", "58", "", "", "87.6", "81.5", "", "45.1", "", "2", "", "", "203", "1", "1", "230", "0", "2", "", "0", "120", "0", "30", "3", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.9", "93.8", "", "", "", "", "93.2"]} +{"pcdb_id": 15602, "brand_name": "Mistral Boilers", "model_name": "CODMC5 41/50", "model_qualifier": "", "winter_efficiency_pct": 87.6, "summer_efficiency_pct": 81.5, "comparative_hot_water_efficiency_pct": 45.1, "output_kw_max": 50.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015602", "000056", "0", "2024/Jan/31 10:17", "Mistral Boilers", "Mistral Boilers", "CODMC5 41/50", "", "", "2007", "current", "4", "1", "2", "2", "0", "", "", "2", "3", "2", "41", "50", "", "", "87.6", "81.5", "", "45.1", "", "2", "", "", "203", "1", "1", "230", "0", "2", "", "0", "120", "0", "30", "3", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.9", "93.8", "", "", "", "", "93.2"]} +{"pcdb_id": 15603, "brand_name": "Mistral Boilers", "model_name": "COD7 SS 58/68", "model_qualifier": "", "winter_efficiency_pct": 87.6, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 68.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015603", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral Boilers", "COD7 SS 58/68", "", "", "2007", "current", "4", "1", "2", "1", "0", "", "", "2", "3", "2", "58", "68", "", "", "87.6", "79.8", "", "58.3", "", "2", "", "", "201", "1", "1", "230", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.9", "93.8", "", "", "", "", "93.2"]} +{"pcdb_id": 15604, "brand_name": "Mistral Boilers", "model_name": "COD6 SS 50/58", "model_qualifier": "", "winter_efficiency_pct": 87.6, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 58.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015604", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral Boilers", "COD6 SS 50/58", "", "", "2007", "current", "4", "1", "2", "1", "0", "", "", "2", "3", "2", "50", "58", "", "", "87.6", "79.8", "", "58.3", "", "2", "", "", "201", "1", "1", "230", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.9", "93.8", "", "", "", "", "93.2"]} +{"pcdb_id": 15605, "brand_name": "Mistral Boilers", "model_name": "COD5 SS 41/50", "model_qualifier": "", "winter_efficiency_pct": 87.6, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 50.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015605", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral Boilers", "COD5 SS 41/50", "", "", "2007", "current", "4", "1", "2", "1", "0", "", "", "2", "3", "2", "41", "50", "", "", "87.6", "79.8", "", "58.3", "", "2", "", "", "201", "1", "1", "230", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.9", "93.8", "", "", "", "", "93.2"]} +{"pcdb_id": 15606, "brand_name": "Mistral Boilers", "model_name": "CS6 50/58", "model_qualifier": "", "winter_efficiency_pct": 87.6, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 58.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015606", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral Boilers", "CS6 50/58", "", "", "2007", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "50", "58", "", "", "87.6", "79.8", "", "58.3", "", "2", "", "", "201", "1", "1", "230", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.9", "93.8", "", "", "", "", "93.2"]} +{"pcdb_id": 15607, "brand_name": "Mistral Boilers", "model_name": "CS5 41/50", "model_qualifier": "", "winter_efficiency_pct": 87.6, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 50.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015607", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral Boilers", "CS5 41/50", "", "", "2007", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "41", "50", "", "", "87.6", "79.8", "", "58.3", "", "2", "", "", "201", "1", "1", "230", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.9", "93.8", "", "", "", "", "93.2"]} +{"pcdb_id": 15608, "brand_name": "Mistral Boilers", "model_name": "CS7 58/68", "model_qualifier": "", "winter_efficiency_pct": 87.6, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 68.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015608", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral Boilers", "CS7 58/68", "", "", "2007", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "58", "68", "", "", "87.6", "79.8", "", "58.3", "", "2", "", "", "201", "1", "1", "230", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.9", "93.8", "", "", "", "", "93.2"]} +{"pcdb_id": 15609, "brand_name": "Mistral Boilers", "model_name": "COD5 41/50", "model_qualifier": "", "winter_efficiency_pct": 87.6, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 50.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015609", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral Boilers", "COD5 41/50", "", "", "2007", "current", "4", "1", "2", "1", "0", "", "", "2", "3", "2", "41", "50", "", "", "87.6", "79.8", "", "58.3", "", "2", "", "", "201", "1", "1", "230", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.9", "93.8", "", "", "", "", "93.2"]} +{"pcdb_id": 15610, "brand_name": "Mistral Boilers", "model_name": "COD6 50/58", "model_qualifier": "", "winter_efficiency_pct": 87.6, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 58.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015610", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral Boilers", "COD6 50/58", "", "", "2007", "current", "4", "1", "2", "1", "0", "", "", "2", "3", "2", "50", "58", "", "", "87.6", "79.8", "", "58.3", "", "2", "", "", "201", "1", "1", "230", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.9", "93.8", "", "", "", "", "93.2"]} +{"pcdb_id": 15611, "brand_name": "Mistral Boilers", "model_name": "COD7 58/68", "model_qualifier": "", "winter_efficiency_pct": 87.6, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 68.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015611", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral Boilers", "COD7 58/68", "", "", "2007", "current", "4", "1", "2", "1", "0", "", "", "2", "3", "2", "58", "68", "", "", "87.6", "79.8", "", "58.3", "", "2", "", "", "201", "1", "1", "230", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.9", "93.8", "", "", "", "", "93.2"]} +{"pcdb_id": 15612, "brand_name": "Alpha", "model_name": "CD20S", "model_qualifier": "", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 18.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015612", "000001", "0", "2012/Mar/27 10:12", "Alpha Therm", "Alpha", "CD20S", "", "", "2007", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "18", "18", "", "", "89.1", "80.1", "", "58.5", "", "2", "1", "", "102", "1", "2", "135", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.8", "99.3", "", "", "", "", "97.5"]} +{"pcdb_id": 15613, "brand_name": "Alpha", "model_name": "CD20S", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 18.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015613", "000001", "0", "2012/Mar/27 10:12", "Alpha Therm", "Alpha", "CD20S", "", "", "2007", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18", "18", "", "", "88.1", "79.1", "", "57.8", "", "2", "", "", "102", "1", "2", "135", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "97.1", "", "", "", "", "95.4"]} +{"pcdb_id": 15614, "brand_name": "Alpha", "model_name": "CD28S", "model_qualifier": "", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 28.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015614", "000001", "0", "2012/Mar/27 10:12", "Alpha Therm", "Alpha", "CD28S", "", "", "2007", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "28", "28", "", "", "89.1", "80.1", "", "58.5", "", "2", "1", "", "102", "1", "2", "125", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.8", "99.4", "", "", "", "", "97.6"]} +{"pcdb_id": 15615, "brand_name": "Alpha", "model_name": "CD28S", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 28.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015615", "000001", "0", "2012/Mar/27 10:12", "Alpha Therm", "Alpha", "CD28S", "", "", "2007", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "28", "28", "", "", "88.1", "79.1", "", "57.8", "", "2", "", "", "102", "1", "2", "125", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "97.2", "", "", "", "", "95.4"]} +{"pcdb_id": 15616, "brand_name": "Alpha", "model_name": "CD12S", "model_qualifier": "", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 12.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015616", "000001", "0", "2012/Mar/27 10:12", "Alpha Therm", "Alpha", "CD12S", "", "", "2007", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "12", "12", "", "", "88.9", "79.9", "", "58.3", "", "2", "1", "", "102", "1", "2", "120", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.8", "98.6", "", "", "", "", "97.0"]} +{"pcdb_id": 15617, "brand_name": "Alpha", "model_name": "CD12S", "model_qualifier": "", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 78.9, "comparative_hot_water_efficiency_pct": 57.6, "output_kw_max": 12.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015617", "000001", "0", "2012/Mar/27 10:12", "Alpha Therm", "Alpha", "CD12S", "", "", "2007", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "12", "12", "", "", "87.9", "78.9", "", "57.6", "", "2", "", "", "102", "1", "2", "120", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "96.5", "", "", "", "", "94.9"]} +{"pcdb_id": 15620, "brand_name": "Trianco", "model_name": "Contractor Utility", "model_qualifier": "100/125", "winter_efficiency_pct": 85.7, "summer_efficiency_pct": 74.0, "comparative_hot_water_efficiency_pct": 54.0, "output_kw_max": 36.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015620", "000062", "0", "2012/Mar/27 10:12", "Trianco Heating Products", "Trianco", "Contractor Utility", "100/125", "2301", "2007", "current", "4", "1", "1", "1", "0", "", "", "1", "3", "2", "29.3", "36.4", "", "", "85.7", "74.0", "", "54.0", "", "2", "", "", "201", "1", "1", "148", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.4", "86.0", "", "", "", "", "85.9"]} +{"pcdb_id": 15621, "brand_name": "Trianco", "model_name": "Contractor 100/125 External", "model_qualifier": "", "winter_efficiency_pct": 85.7, "summer_efficiency_pct": 74.0, "comparative_hot_water_efficiency_pct": 54.0, "output_kw_max": 36.4, "final_year_of_manufacture": 2008, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015621", "000062", "0", "2012/Mar/27 10:12", "Trianco Heating Products", "Trianco", "Contractor 100/125 External", "", "2311", "2007", "2008", "4", "1", "1", "1", "0", "", "", "1", "3", "2", "29.3", "36.4", "", "", "85.7", "74.0", "", "54.0", "", "2", "", "", "201", "1", "1", "148", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.4", "86.0", "", "", "", "", "85.9"]} +{"pcdb_id": 15622, "brand_name": "Trianco", "model_name": "Iona External 100/125 HE", "model_qualifier": "", "winter_efficiency_pct": 84.6, "summer_efficiency_pct": 76.8, "comparative_hot_water_efficiency_pct": 56.1, "output_kw_max": 36.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015622", "000062", "0", "2012/Mar/27 10:12", "Trianco Heating Products", "Trianco", "Iona External 100/125 HE", "", "2396", "2007", "current", "4", "1", "2", "1", "0", "", "", "2", "3", "2", "30", "36.4", "", "", "84.6", "76.8", "", "56.1", "", "2", "", "", "201", "1", "1", "148", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "87.8", "89.1", "", "", "", "", "88.9"]} +{"pcdb_id": 15623, "brand_name": "Trianco", "model_name": "Iona 100/125 HE", "model_qualifier": "", "winter_efficiency_pct": 84.6, "summer_efficiency_pct": 76.8, "comparative_hot_water_efficiency_pct": 56.1, "output_kw_max": 36.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015623", "000062", "0", "2012/Mar/27 10:12", "Trianco Heating Products", "Trianco", "Iona 100/125 HE", "", "2392", "2007", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "30", "36.4", "", "", "84.6", "76.8", "", "56.1", "", "2", "", "", "201", "1", "1", "148", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "87.8", "89.1", "", "", "", "", "88.9"]} +{"pcdb_id": 15624, "brand_name": "Trianco", "model_name": "Contractor 100/125 External HE", "model_qualifier": "", "winter_efficiency_pct": 84.6, "summer_efficiency_pct": 76.8, "comparative_hot_water_efficiency_pct": 56.1, "output_kw_max": 36.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015624", "000062", "0", "2012/Mar/27 10:12", "Trianco Heating Products", "Trianco", "Contractor 100/125 External HE", "", "2376", "2007", "current", "4", "1", "2", "1", "0", "", "", "2", "3", "2", "30", "36.4", "", "", "84.6", "76.8", "", "56.1", "", "2", "", "", "201", "1", "1", "148", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "87.8", "89.1", "", "", "", "", "88.9"]} +{"pcdb_id": 15625, "brand_name": "Trianco", "model_name": "Contractor Utility HE", "model_qualifier": "100/125", "winter_efficiency_pct": 84.8, "summer_efficiency_pct": 77.0, "comparative_hot_water_efficiency_pct": 56.3, "output_kw_max": 38.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015625", "000062", "0", "2012/Mar/27 10:12", "Trianco Heating Products", "Trianco", "Contractor Utility HE", "100/125", "2372", "2007", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "30", "38", "", "", "84.8", "77.0", "", "56.3", "", "2", "", "", "201", "1", "1", "148", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "87.8", "89.7", "", "", "", "", "89.3"]} +{"pcdb_id": 15626, "brand_name": "Trianco", "model_name": "Contractor Utility", "model_qualifier": "130/180", "winter_efficiency_pct": 86.5, "summer_efficiency_pct": 74.8, "comparative_hot_water_efficiency_pct": 54.7, "output_kw_max": 53.0, "final_year_of_manufacture": 2007, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015626", "000062", "0", "2012/Mar/27 10:12", "Trianco Heating Products", "Trianco", "Contractor Utility", "130/180", "2296E", "2007", "2007", "4", "1", "1", "1", "0", "", "", "1", "3", "2", "38", "53", "", "", "86.5", "74.8", "", "54.7", "", "2", "", "", "201", "1", "1", "148", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.0", "86.9", "", "", "", "", "86.9"]} +{"pcdb_id": 15627, "brand_name": "Trianco", "model_name": "Iona HE", "model_qualifier": "130/180", "winter_efficiency_pct": 85.5, "summer_efficiency_pct": 77.7, "comparative_hot_water_efficiency_pct": 56.8, "output_kw_max": 52.8, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015627", "000062", "0", "2012/Mar/27 10:12", "Trianco Heating Products", "Trianco", "Iona HE", "130/180", "2393", "2007", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "41.4", "52.8", "", "", "85.5", "77.7", "", "56.8", "", "2", "", "", "201", "1", "1", "148", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "88.8", "90.0", "", "", "", "", "89.8"]} +{"pcdb_id": 15628, "brand_name": "Trianco", "model_name": "Contractor Utility HE", "model_qualifier": "130/180", "winter_efficiency_pct": 85.5, "summer_efficiency_pct": 77.7, "comparative_hot_water_efficiency_pct": 56.8, "output_kw_max": 53.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015628", "000062", "0", "2012/Mar/27 10:12", "Trianco Heating Products", "Trianco", "Contractor Utility HE", "130/180", "2373", "2007", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "41.4", "53.0", "", "", "85.5", "77.7", "", "56.8", "", "2", "", "", "201", "1", "1", "148", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "88.8", "90.0", "", "", "", "", "89.8"]} +{"pcdb_id": 15629, "brand_name": "Trianco", "model_name": "Contractor Utility", "model_qualifier": "190/220", "winter_efficiency_pct": 86.3, "summer_efficiency_pct": 74.6, "comparative_hot_water_efficiency_pct": 54.5, "output_kw_max": 64.0, "final_year_of_manufacture": 2007, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015629", "000062", "0", "2012/Mar/27 10:12", "Trianco Heating Products", "Trianco", "Contractor Utility", "190/220", "2298E", "2007", "2007", "4", "1", "1", "1", "0", "", "", "1", "3", "2", "55.7", "64", "", "", "86.3", "74.6", "", "54.5", "", "2", "", "", "201", "1", "1", "148", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "85.5", "87.2", "", "", "", "", "86.9"]} +{"pcdb_id": 15630, "brand_name": "Trianco", "model_name": "Iona HE", "model_qualifier": "190/220", "winter_efficiency_pct": 84.5, "summer_efficiency_pct": 76.7, "comparative_hot_water_efficiency_pct": 56.0, "output_kw_max": 64.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015630", "000062", "0", "2012/Mar/27 10:12", "Trianco Heating Products", "Trianco", "Iona HE", "190/220", "2394", "2007", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "56.5", "64.6", "", "", "84.5", "76.7", "", "56.0", "", "2", "", "", "201", "1", "1", "148", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "88.0", "88.8", "", "", "", "", "88.7"]} +{"pcdb_id": 15631, "brand_name": "Trianco", "model_name": "Contractor Utility HE", "model_qualifier": "190/220", "winter_efficiency_pct": 84.5, "summer_efficiency_pct": 76.7, "comparative_hot_water_efficiency_pct": 56.0, "output_kw_max": 65.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015631", "000062", "0", "2012/Mar/27 10:12", "Trianco Heating Products", "Trianco", "Contractor Utility HE", "190/220", "2374", "2007", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "56.5", "65", "", "", "84.5", "76.7", "", "56.0", "", "2", "", "", "201", "1", "1", "148", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "88.0", "88.8", "", "", "", "", "88.7"]} +{"pcdb_id": 15632, "brand_name": "Trianco", "model_name": "Contractor Combi", "model_qualifier": "110 HE", "winter_efficiency_pct": 86.4, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 55.5, "output_kw_max": 33.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015632", "000062", "0", "2007/Sep/20 10:37", "Trianco Heating Products", "Trianco", "Contractor Combi", "110 HE", "2388", "2007", "current", "4", "1", "1", "2", "0", "", "", "2", "3", "2", "33.4", "33.4", "", "", "86.4", "79.0", "", "55.5", "", "2", "", "", "202", "1", "1", "148", "0", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "89.5", "91.2", "", "", "", "", "90.8"]} +{"pcdb_id": 15633, "brand_name": "Trianco", "model_name": "Contractor 110 HE EXT Combi", "model_qualifier": "", "winter_efficiency_pct": 86.4, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 55.5, "output_kw_max": 33.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015633", "000062", "0", "2007/Sep/20 10:38", "Trianco Heating Products", "Trianco", "Contractor 110 HE EXT Combi", "", "", "2007", "current", "4", "1", "2", "2", "0", "", "", "2", "3", "2", "33.4", "33.4", "", "", "86.4", "79.0", "", "55.5", "", "2", "", "", "202", "1", "1", "148", "0", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "89.5", "91.2", "", "", "", "", "90.8"]} +{"pcdb_id": 15634, "brand_name": "Trianco", "model_name": "Iona", "model_qualifier": "110 HE Combi", "winter_efficiency_pct": 86.4, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 55.5, "output_kw_max": 33.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015634", "000062", "0", "2007/Sep/20 10:40", "Trianco Heating Products", "Trianco", "Iona", "110 HE Combi", "2408", "2007", "current", "4", "1", "1", "2", "0", "", "", "2", "3", "2", "33.4", "33.4", "", "", "86.4", "79.0", "", "55.5", "", "2", "", "", "202", "1", "1", "148", "0", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "89.5", "91.2", "", "", "", "", "90.8"]} +{"pcdb_id": 15635, "brand_name": "Trianco", "model_name": "Iona 110 HE External Combi", "model_qualifier": "", "winter_efficiency_pct": 86.4, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 55.5, "output_kw_max": 33.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015635", "000062", "0", "2007/Sep/20 10:41", "Trianco Heating Products", "Trianco", "Iona 110 HE External Combi", "", "", "2007", "current", "4", "1", "1", "2", "0", "", "", "2", "3", "2", "33.4", "33.4", "", "", "86.4", "79.0", "", "55.5", "", "2", "", "", "202", "1", "1", "148", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "89.5", "91.2", "", "", "", "", "90.8"]} +{"pcdb_id": 15636, "brand_name": "Trianco", "model_name": "Contractor", "model_qualifier": "50/70 WM HE", "winter_efficiency_pct": 86.0, "summer_efficiency_pct": 78.2, "comparative_hot_water_efficiency_pct": 57.2, "output_kw_max": 21.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015636", "000062", "0", "2012/Mar/27 10:12", "Trianco Heating Products", "Trianco", "Contractor", "50/70 WM HE", "2385", "2007", "current", "4", "2", "1", "1", "0", "", "", "2", "2", "2", "14.88", "21.3", "", "", "86.0", "78.2", "", "57.2", "", "2", "", "", "201", "1", "1", "148", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "89.0", "91.0", "", "", "", "", "90.6"]} +{"pcdb_id": 15637, "brand_name": "Trianco", "model_name": "Contractor", "model_qualifier": "50/70 WM HE EXT", "winter_efficiency_pct": 86.0, "summer_efficiency_pct": 78.2, "comparative_hot_water_efficiency_pct": 57.2, "output_kw_max": 21.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015637", "000062", "0", "2012/Mar/27 10:12", "Trianco Heating Products", "Trianco", "Contractor", "50/70 WM HE EXT", "2386", "2007", "current", "4", "2", "1", "1", "0", "", "", "2", "2", "2", "14.88", "21.3", "", "", "86.0", "78.2", "", "57.2", "", "2", "", "", "201", "1", "1", "148", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "89.0", "91.0", "", "", "", "", "90.6"]} +{"pcdb_id": 15638, "brand_name": "Trianco", "model_name": "Iona", "model_qualifier": "50/70 WM HE", "winter_efficiency_pct": 86.0, "summer_efficiency_pct": 78.2, "comparative_hot_water_efficiency_pct": 57.2, "output_kw_max": 21.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015638", "000062", "0", "2012/Mar/27 10:12", "Trianco Heating Products", "Trianco", "Iona", "50/70 WM HE", "", "2007", "current", "4", "2", "1", "1", "0", "", "", "2", "2", "2", "14.88", "21.3", "", "", "86.0", "78.2", "", "57.2", "", "2", "", "", "201", "1", "1", "148", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "89.0", "91.0", "", "", "", "", "90.6"]} +{"pcdb_id": 15639, "brand_name": "Trianco", "model_name": "Iona", "model_qualifier": "50/70 WM HE External", "winter_efficiency_pct": 86.0, "summer_efficiency_pct": 78.2, "comparative_hot_water_efficiency_pct": 57.2, "output_kw_max": 21.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015639", "000062", "0", "2012/Mar/27 10:12", "Trianco Heating Products", "Trianco", "Iona", "50/70 WM HE External", "2406", "2007", "current", "4", "2", "1", "1", "0", "", "", "2", "2", "2", "14.88", "21.3", "", "", "86.0", "78.2", "", "57.2", "", "2", "", "", "201", "1", "1", "148", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "89.0", "91.0", "", "", "", "", "90.6"]} +{"pcdb_id": 15641, "brand_name": "Biasi", "model_name": "Parva HE System", "model_qualifier": "M96.32SR/P", "winter_efficiency_pct": 87.4, "summer_efficiency_pct": 78.4, "comparative_hot_water_efficiency_pct": 57.3, "output_kw_max": 32.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015641", "000208", "0", "2012/Mar/27 10:12", "Biasi (UK)", "Biasi", "Parva HE System", "M96.32SR/P", "", "2007", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "32.2", "32.2", "", "", "87.4", "78.4", "", "57.3", "", "2", "0", "", "102", "1", "2", "150", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.1", "92.7", "", "", "", "", "92.0"]} +{"pcdb_id": 15642, "brand_name": "Biasi", "model_name": "Parva HE System", "model_qualifier": "M96.32SR/P", "winter_efficiency_pct": 85.5, "summer_efficiency_pct": 76.5, "comparative_hot_water_efficiency_pct": 55.9, "output_kw_max": 32.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015642", "000208", "0", "2012/Mar/27 10:12", "Biasi (UK)", "Biasi", "Parva HE System", "M96.32SR/P", "41-583-06", "2007", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "32.2", "32.2", "", "", "85.5", "76.5", "", "55.9", "", "2", "", "", "102", "1", "2", "150", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.1", "90.7", "", "", "", "", "90.0"]} +{"pcdb_id": 15644, "brand_name": "Biasi", "model_name": "Parva HE System", "model_qualifier": "M96.28SR/P", "winter_efficiency_pct": 86.3, "summer_efficiency_pct": 77.3, "comparative_hot_water_efficiency_pct": 56.5, "output_kw_max": 27.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015644", "000208", "0", "2012/Mar/27 10:12", "Biasi (UK)", "Biasi", "Parva HE System", "M96.28SR/P", "", "2007", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "27.4", "27.4", "", "", "86.3", "77.3", "", "56.5", "", "2", "0", "", "102", "1", "2", "150", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.1", "91.4", "", "", "", "", "90.6"]} +{"pcdb_id": 15645, "brand_name": "Biasi", "model_name": "Parva HE Systen", "model_qualifier": "M96.28SR/P", "winter_efficiency_pct": 85.9, "summer_efficiency_pct": 76.9, "comparative_hot_water_efficiency_pct": 56.2, "output_kw_max": 28.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015645", "000208", "0", "2012/Mar/27 10:12", "Biasi (UK)", "Biasi", "Parva HE Systen", "M96.28SR/P", "41-583-05", "2007", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "28.3", "28.3", "", "", "85.9", "76.9", "", "56.2", "", "2", "", "", "102", "1", "2", "150", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "91.5", "", "", "", "", "90.8"]} +{"pcdb_id": 15646, "brand_name": "Biasi", "model_name": "Parva HE Combi", "model_qualifier": "M96.32SM/P", "winter_efficiency_pct": 87.4, "summer_efficiency_pct": 78.8, "comparative_hot_water_efficiency_pct": 55.4, "output_kw_max": 32.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015646", "000208", "0", "2007/Oct/09 08:37", "Biasi (UK)", "Biasi", "Parva HE Combi", "M96.32SM/P", "", "2007", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "32.2", "32.2", "", "", "87.4", "78.8", "", "55.4", "", "2", "0", "", "104", "1", "2", "150", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.1", "92.7", "", "", "", "", "92.0"]} +{"pcdb_id": 15647, "brand_name": "Biasi", "model_name": "Parva HE Combi", "model_qualifier": "M96.32SM/P", "winter_efficiency_pct": 85.5, "summer_efficiency_pct": 76.9, "comparative_hot_water_efficiency_pct": 54.1, "output_kw_max": 32.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015647", "000208", "0", "2007/Sep/28 13:04", "Biasi (UK)", "Biasi", "Parva HE Combi", "M96.32SM/P", "47-583-10", "2007", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "32.2", "32.2", "", "", "85.5", "76.9", "", "54.1", "", "2", "", "", "104", "1", "2", "150", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.1", "90.7", "", "", "", "", "90.0"]} +{"pcdb_id": 15648, "brand_name": "Biasi", "model_name": "Parva HE Combi", "model_qualifier": "M96.28SM/P", "winter_efficiency_pct": 86.3, "summer_efficiency_pct": 77.7, "comparative_hot_water_efficiency_pct": 54.6, "output_kw_max": 27.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015648", "000208", "0", "2007/Oct/09 08:38", "Biasi (UK)", "Biasi", "Parva HE Combi", "M96.28SM/P", "", "2007", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "27.4", "27.4", "", "", "86.3", "77.7", "", "54.6", "", "2", "0", "", "104", "1", "2", "150", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.1", "91.4", "", "", "", "", "90.6"]} +{"pcdb_id": 15649, "brand_name": "Biasi", "model_name": "Parva HE Combi", "model_qualifier": "M96.28SM/P", "winter_efficiency_pct": 85.9, "summer_efficiency_pct": 77.3, "comparative_hot_water_efficiency_pct": 54.4, "output_kw_max": 28.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015649", "000208", "0", "2007/Sep/28 13:05", "Biasi (UK)", "Biasi", "Parva HE Combi", "M96.28SM/P", "47-583-09", "2007", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28.3", "28.3", "", "", "85.9", "77.3", "", "54.4", "", "2", "", "", "104", "1", "2", "150", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "91.5", "", "", "", "", "90.8"]} +{"pcdb_id": 15650, "brand_name": "Biasi", "model_name": "Parva HE Combi", "model_qualifier": "M96.24SM/P", "winter_efficiency_pct": 86.2, "summer_efficiency_pct": 77.6, "comparative_hot_water_efficiency_pct": 54.5, "output_kw_max": 23.7, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015650", "000208", "0", "2007/Oct/09 08:38", "Biasi (UK)", "Biasi", "Parva HE Combi", "M96.24SM/P", "47-583-08", "2007", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "23.7", "23.7", "", "", "86.2", "77.6", "", "54.5", "", "2", "0", "", "104", "1", "2", "140", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.3", "90.8", "", "", "", "", "90.1"]} +{"pcdb_id": 15651, "brand_name": "Biasi", "model_name": "Parva HE Combi", "model_qualifier": "M96.24SM/P", "winter_efficiency_pct": 85.8, "summer_efficiency_pct": 77.2, "comparative_hot_water_efficiency_pct": 54.3, "output_kw_max": 24.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015651", "000208", "0", "2007/Sep/28 13:05", "Biasi (UK)", "Biasi", "Parva HE Combi", "M96.24SM/P", "47-583-08", "2007", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.6", "24.6", "", "", "85.8", "77.2", "", "54.3", "", "2", "", "", "104", "1", "2", "140", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.7", "90.9", "", "", "", "", "90.5"]} +{"pcdb_id": 15652, "brand_name": "Ariston", "model_name": "Clas 24 FF", "model_qualifier": "", "winter_efficiency_pct": 82.4, "summer_efficiency_pct": 72.3, "comparative_hot_water_efficiency_pct": 50.9, "output_kw_max": 24.2, "final_year_of_manufacture": 2008, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015652", "000080", "0", "2009/Jul/28 09:41", "Merloni TermoSanitari SpA", "Ariston", "Clas 24 FF", "", "47-116-59", "2007", "2008", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "24.2", "24.2", "", "", "82.4", "72.3", "", "50.9", "", "2", "", "", "104", "1", "2", "126", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "84.5", "84.3", "", "", "", "", "84.4"]} +{"pcdb_id": 15653, "brand_name": "Ariston", "model_name": "Clas 28 FF System", "model_qualifier": "", "winter_efficiency_pct": 82.4, "summer_efficiency_pct": 71.7, "comparative_hot_water_efficiency_pct": 52.4, "output_kw_max": 28.1, "final_year_of_manufacture": 2008, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015653", "000080", "0", "2012/Mar/27 10:12", "Merloni TermoSanitari SpA", "Ariston", "Clas 28 FF System", "", "41-116-28", "2007", "2008", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "28.1", "28.1", "", "", "82.4", "71.7", "", "52.4", "", "2", "", "", "102", "1", "2", "126", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "84.3", "84.0", "", "", "", "", "84.0"]} +{"pcdb_id": 15654, "brand_name": "Ariston", "model_name": "Clas 21 FF System", "model_qualifier": "", "winter_efficiency_pct": 82.6, "summer_efficiency_pct": 71.9, "comparative_hot_water_efficiency_pct": 52.5, "output_kw_max": 24.2, "final_year_of_manufacture": 2008, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015654", "000080", "0", "2012/Mar/27 10:12", "Merloni TermoSanitari SpA", "Ariston", "Clas 21 FF System", "", "41-116-27", "2007", "2008", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "24.2", "24.2", "", "", "82.6", "71.9", "", "52.5", "", "2", "", "", "102", "1", "2", "126", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "84.5", "84.3", "", "", "", "", "84.4"]} +{"pcdb_id": 15655, "brand_name": "Ariston", "model_name": "Clas HE 18 System", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 17.6, "final_year_of_manufacture": 2013, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015655", "000080", "0", "2013/Nov/04 15:25", "Merloni TermoSanitari SpA", "Ariston", "Clas HE 18 System", "", "41-116-26", "2007", "2013", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "17.6", "17.6", "", "", "88.6", "79.6", "", "58.1", "", "2", "", "", "102", "1", "2", "105", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "98.2", "", "", "", "", "96.3"]} +{"pcdb_id": 15660, "brand_name": "Warmflow", "model_name": "G-Series", "model_qualifier": "GS25B", "winter_efficiency_pct": 85.2, "summer_efficiency_pct": 76.2, "comparative_hot_water_efficiency_pct": 55.7, "output_kw_max": 25.51, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015660", "000063", "0", "2012/Mar/27 10:12", "Radiant Bruciatori SpA", "Warmflow", "G-Series", "GS25B", "", "2007", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "25.51", "25.51", "", "", "85.2", "76.2", "", "55.7", "", "2", "", "", "102", "1", "2", "210", "5.4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "85.8", "90.8", "", "", "", "", "89.9"]} +{"pcdb_id": 15661, "brand_name": "Warmflow", "model_name": "G-Series", "model_qualifier": "GS25A", "winter_efficiency_pct": 87.7, "summer_efficiency_pct": 78.7, "comparative_hot_water_efficiency_pct": 57.5, "output_kw_max": 26.67, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015661", "000063", "0", "2012/Mar/27 10:12", "Radiant Bruciatori SpA", "Warmflow", "G-Series", "GS25A", "", "2007", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "26.67", "26.67", "", "", "87.7", "78.7", "", "57.5", "", "2", "", "", "102", "1", "2", "170", "5.4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.7", "95.8", "", "", "", "", "94.4"]} +{"pcdb_id": 15662, "brand_name": "Warmflow", "model_name": "G-Series", "model_qualifier": "GC29B", "winter_efficiency_pct": 84.9, "summer_efficiency_pct": 76.3, "comparative_hot_water_efficiency_pct": 53.7, "output_kw_max": 29.01, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015662", "000063", "0", "2007/Nov/26 10:03", "Radiant Bruciatori SpA", "Warmflow", "G-Series", "GC29B", "", "2007", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "29.01", "29.01", "", "", "84.9", "76.3", "", "53.7", "", "2", "", "", "104", "1", "2", "175", "5.4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.1", "89.3", "", "", "", "", "88.9"]} +{"pcdb_id": 15663, "brand_name": "Warmflow", "model_name": "G-Series", "model_qualifier": "GC29A", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 55.9, "output_kw_max": 29.43, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015663", "000063", "0", "2007/Nov/26 10:03", "Radiant Bruciatori SpA", "Warmflow", "G-Series", "GC29A", "", "2007", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "29.43", "29.43", "", "", "88.1", "79.5", "", "55.9", "", "2", "", "", "104", "1", "2", "180", "5.4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.4", "96.9", "", "", "", "", "95.3"]} +{"pcdb_id": 15665, "brand_name": "Worcester", "model_name": "Greenstar Camray System", "model_qualifier": "12/18", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 58.7, "output_kw_max": 18.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015665", "000035", "0", "2020/Sep/08 09:52", "Worcester Bosch Group", "Worcester", "Greenstar Camray System", "12/18", "Greenstar Camray 12/18-RSO-GB Oil System", "2007", "2015", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "12", "18", "", "", "88.1", "80.3", "", "58.7", "", "2", "", "", "201", "1", "1", "255", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.4", "94.8", "", "", "", "", "94.2"]} +{"pcdb_id": 15666, "brand_name": "Worcester", "model_name": "Greenstar Camray System", "model_qualifier": "18/25", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 80.6, "comparative_hot_water_efficiency_pct": 58.9, "output_kw_max": 25.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015666", "000035", "0", "2020/Sep/08 09:52", "Worcester Bosch Group", "Worcester", "Greenstar Camray System", "18/25", "Greenstar Camray 18/25-RSO-GB Oil System", "2007", "2015", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "18", "25", "", "", "88.4", "80.6", "", "58.9", "", "2", "", "", "201", "1", "1", "265", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.5", "95.9", "", "", "", "", "94.8"]} +{"pcdb_id": 15667, "brand_name": "Worcester", "model_name": "Greenstar Camray System", "model_qualifier": "25/32", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 81.1, "comparative_hot_water_efficiency_pct": 59.3, "output_kw_max": 30.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015667", "000035", "0", "2020/Sep/08 10:00", "Worcester Bosch Group", "Worcester", "Greenstar Camray System", "25/32", "Greenstar Camray 25/32-RSO-GB Oil System", "2007", "2015", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "25", "30", "", "", "88.9", "81.1", "", "59.3", "", "2", "", "", "201", "1", "1", "265", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.5", "96.9", "", "", "", "", "95.9"]} +{"pcdb_id": 15668, "brand_name": "Sime", "model_name": "Murelle HE", "model_qualifier": "35 BFT", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 34.1, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015668", "000213", "0", "2018/Mar/05 16:56", "Fonderie Sime S.p.A.", "Sime", "Murelle HE", "35 BFT", "", "2008", "2018", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "34.1", "34.1", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "145", "8", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.5", "96.2", "", "", "", "", "94.9"]} +{"pcdb_id": 15669, "brand_name": "Sime", "model_name": "Murelle HE", "model_qualifier": "35 BFT", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 34.1, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015669", "000213", "0", "2018/Mar/05 16:56", "Fonderie Sime S.p.A.", "Sime", "Murelle HE", "35 BFT", "", "2008", "2018", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "34.1", "34.1", "", "", "89.0", "80.0", "", "58.4", "", "2", "1", "", "102", "1", "2", "145", "8", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "91.5", "98.4", "", "", "", "", "97.1"]} +{"pcdb_id": 15670, "brand_name": "Sime", "model_name": "Murelle HE", "model_qualifier": "35 BF", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 55.8, "output_kw_max": 34.1, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015670", "000213", "0", "2018/Mar/05 16:55", "Fonderie Sime S.p.A.", "Sime", "Murelle HE", "35 BF", "", "2008", "2018", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "34.1", "34.1", "", "", "88.0", "79.4", "", "55.8", "", "2", "", "", "104", "1", "2", "140", "8", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.5", "96.2", "", "", "", "", "94.9"]} +{"pcdb_id": 15671, "brand_name": "Sime", "model_name": "Murelle HE", "model_qualifier": "35 BF", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.4, "comparative_hot_water_efficiency_pct": 56.6, "output_kw_max": 34.1, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015671", "000213", "0", "2018/Mar/05 16:55", "Fonderie Sime S.p.A.", "Sime", "Murelle HE", "35 BF", "", "2008", "2018", "2", "2", "1", "2", "0", "", "", "2", "3", "2", "34.1", "34.1", "", "", "89.0", "80.4", "", "56.6", "", "2", "1", "", "104", "1", "2", "140", "8", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "91.5", "98.4", "", "", "", "", "97.1"]} +{"pcdb_id": 15672, "brand_name": "Sime", "model_name": "Murelle HE", "model_qualifier": "30 BFT", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 28.9, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015672", "000213", "0", "2018/Mar/05 16:51", "Fonderie Sime S.p.A.", "Sime", "Murelle HE", "30 BFT", "", "2008", "2018", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "28.9", "28.9", "", "", "88.2", "79.2", "", "57.9", "", "2", "", "", "102", "1", "2", "135", "8", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.7", "97.0", "", "", "", "", "95.4"]} +{"pcdb_id": 15673, "brand_name": "Sime", "model_name": "Murelle HE", "model_qualifier": "30 BFT", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 28.9, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015673", "000213", "0", "2018/Mar/05 16:52", "Fonderie Sime S.p.A.", "Sime", "Murelle HE", "30 BFT", "", "2008", "2018", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "28.9", "28.9", "", "", "89.2", "80.2", "", "58.6", "", "2", "1", "", "102", "1", "2", "135", "8", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.6", "99.2", "", "", "", "", "97.6"]} +{"pcdb_id": 15674, "brand_name": "Sime", "model_name": "Murelle HE", "model_qualifier": "30 BF", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 56.0, "output_kw_max": 28.9, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015674", "000213", "0", "2018/Mar/05 16:50", "Fonderie Sime S.p.A.", "Sime", "Murelle HE", "30 BF", "", "2008", "2018", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "28.9", "28.9", "", "", "88.2", "79.6", "", "56.0", "", "2", "", "", "104", "1", "2", "130", "8", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.7", "97.0", "", "", "", "", "95.4"]} +{"pcdb_id": 15675, "brand_name": "Sime", "model_name": "Murelle HE", "model_qualifier": "30 BF", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 80.6, "comparative_hot_water_efficiency_pct": 56.7, "output_kw_max": 28.9, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015675", "000213", "0", "2018/Mar/05 16:51", "Fonderie Sime S.p.A.", "Sime", "Murelle HE", "30 BF", "", "2008", "2018", "2", "2", "1", "2", "0", "", "", "2", "3", "2", "28.9", "28.9", "", "", "89.2", "80.6", "", "56.7", "", "2", "1", "", "104", "1", "2", "130", "8", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.6", "99.2", "", "", "", "", "97.6"]} +{"pcdb_id": 15676, "brand_name": "Sime", "model_name": "Murelle HE", "model_qualifier": "25 BFT", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 23.9, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015676", "000213", "0", "2018/Mar/05 16:43", "Fonderie Sime S.p.A.", "Sime", "Murelle HE", "25 BFT", "", "2008", "2018", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "23.9", "23.9", "", "", "88.2", "79.2", "", "57.9", "", "2", "", "", "102", "1", "2", "130", "8", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.5", "97.1", "", "", "", "", "95.5"]} +{"pcdb_id": 15677, "brand_name": "Sime", "model_name": "Murelle HE", "model_qualifier": "25 BFT", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 23.9, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015677", "000213", "0", "2018/Mar/05 16:44", "Fonderie Sime S.p.A.", "Sime", "Murelle HE", "25 BFT", "", "2008", "2018", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "23.9", "23.9", "", "", "89.2", "80.2", "", "58.6", "", "2", "1", "", "102", "1", "2", "130", "8", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.4", "99.3", "", "", "", "", "97.6"]} +{"pcdb_id": 15678, "brand_name": "Sime", "model_name": "Murelle HE", "model_qualifier": "25 BF", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 56.0, "output_kw_max": 23.9, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015678", "000213", "0", "2018/Mar/05 16:42", "Fonderie Sime S.p.A.", "Sime", "Murelle HE", "25 BF", "", "2008", "2018", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "23.9", "23.9", "", "", "88.2", "79.6", "", "56.0", "", "2", "", "", "104", "1", "2", "125", "8", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.5", "97.1", "", "", "", "", "95.5"]} +{"pcdb_id": 15679, "brand_name": "Sime", "model_name": "Murelle HE", "model_qualifier": "25 BF", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 80.6, "comparative_hot_water_efficiency_pct": 56.7, "output_kw_max": 23.9, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015679", "000213", "0", "2018/Mar/05 16:42", "Fonderie Sime S.p.A.", "Sime", "Murelle HE", "25 BF", "", "2008", "2018", "2", "2", "1", "2", "0", "", "", "2", "3", "2", "23.9", "23.9", "", "", "89.2", "80.6", "", "56.7", "", "2", "1", "", "104", "1", "2", "125", "8", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.4", "99.3", "", "", "", "", "97.6"]} +{"pcdb_id": 15680, "brand_name": "Sime", "model_name": "Murelle HE", "model_qualifier": "20 BFT", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 19.0, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015680", "000213", "0", "2018/Mar/05 16:40", "Fonderie Sime S.p.A.", "Sime", "Murelle HE", "20 BFT", "", "2008", "2018", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "19", "19", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "125", "8", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.2", "96.8", "", "", "", "", "95.1"]} +{"pcdb_id": 15681, "brand_name": "Sime", "model_name": "Murelle HE", "model_qualifier": "20 BFT", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 19.0, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015681", "000213", "0", "2018/Mar/05 16:41", "Fonderie Sime S.p.A.", "Sime", "Murelle HE", "20 BFT", "", "2008", "2018", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "19", "19", "", "", "89.0", "80.0", "", "58.5", "", "2", "1", "", "102", "1", "2", "125", "8", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.2", "98.9", "", "", "", "", "97.3"]} +{"pcdb_id": 15682, "brand_name": "Sime", "model_name": "Murelle HE", "model_qualifier": "12 BFT", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 11.7, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015682", "000213", "0", "2018/Mar/05 16:37", "Fonderie Sime S.p.A.", "Sime", "Murelle HE", "12 BFT", "", "2008", "2018", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "11.7", "11.7", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "115", "8", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.2", "96.6", "", "", "", "", "95.0"]} +{"pcdb_id": 15683, "brand_name": "Sime", "model_name": "Murelle HE", "model_qualifier": "12 BFT", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 11.7, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015683", "000213", "0", "2018/Mar/05 16:38", "Fonderie Sime S.p.A.", "Sime", "Murelle HE", "12 BFT", "", "2008", "2018", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "11.7", "11.7", "", "", "89.0", "80.0", "", "58.4", "", "2", "1", "", "102", "1", "2", "115", "8", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.2", "98.7", "", "", "", "", "97.1"]} +{"pcdb_id": 15684, "brand_name": "Ideal", "model_name": "Esprit", "model_qualifier": "HE 24", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 56.0, "output_kw_max": 23.4, "final_year_of_manufacture": 2010, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015684", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "Esprit", "HE 24", "47-348-46", "2007", "2010", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "8.8", "23.4", "", "", "88.3", "79.7", "", "56.0", "", "2", "", "", "104", "1", "2", "140", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.1", "97.4", "", "", "", "", "95.6"]} +{"pcdb_id": 15685, "brand_name": "Ideal", "model_name": "Esprit", "model_qualifier": "HE 30", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 56.0, "output_kw_max": 29.3, "final_year_of_manufacture": 2010, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015685", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "Esprit", "HE 30", "47-348-47", "2007", "2010", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "8.8", "29.3", "", "", "88.3", "79.7", "", "56.0", "", "2", "", "", "104", "1", "2", "175", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.1", "97.4", "", "", "", "", "95.6"]} +{"pcdb_id": 15686, "brand_name": "Ideal", "model_name": "Esprit", "model_qualifier": "HE 35", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 56.0, "output_kw_max": 35.2, "final_year_of_manufacture": 2010, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015686", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "Esprit", "HE 35", "47-348-48", "2007", "2010", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "8.8", "35.2", "", "", "88.3", "79.7", "", "56.0", "", "2", "", "", "104", "1", "2", "170", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.1", "97.4", "", "", "", "", "95.6"]} +{"pcdb_id": 15687, "brand_name": "Ideal", "model_name": "Elise", "model_qualifier": "H15", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 14.6, "final_year_of_manufacture": 2010, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015687", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "Elise", "H15", "41-399-97", "2007", "2010", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "14.6", "14.6", "", "", "89.0", "80.0", "", "58.4", "", "2", "", "", "102", "1", "2", "38", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.5", "99.0", "", "", "", "", "97.0"]} +{"pcdb_id": 15688, "brand_name": "Ideal", "model_name": "Elise", "model_qualifier": "H24", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 23.4, "final_year_of_manufacture": 2010, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015688", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "Elise", "H24", "41-399-98", "2007", "2010", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "23.4", "23.4", "", "", "88.1", "79.1", "", "57.8", "", "2", "", "", "102", "1", "2", "38", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "97.1", "", "", "", "", "95.4"]} +{"pcdb_id": 15689, "brand_name": "Baxi", "model_name": "Megaflo System", "model_qualifier": "15 HE A", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 15.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015689", "000005", "0", "2015/Aug/06 10:39", "Baxi Heating", "Baxi", "Megaflo System", "15 HE A", "GC No. 41-075-55", "2008", "2015", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "15", "15", "", "", "88.3", "79.3", "", "57.9", "", "2", "", "", "102", "1", "2", "130", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.9", "96.8", "", "", "", "", "95.5"]} +{"pcdb_id": 15690, "brand_name": "Baxi", "model_name": "Megaflo System", "model_qualifier": "18 HE A", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 18.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015690", "000005", "0", "2015/Aug/06 11:47", "Baxi Heating", "Baxi", "Megaflo System", "18 HE A", "GC No. 41-075-56", "2008", "2015", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18", "18", "", "", "88.3", "79.3", "", "58.0", "", "2", "", "", "102", "1", "2", "140", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.9", "96.9", "", "", "", "", "95.5"]} +{"pcdb_id": 15691, "brand_name": "Baxi", "model_name": "Megaflo System", "model_qualifier": "24 HE A", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 24.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015691", "000005", "0", "2015/Aug/06 11:48", "Baxi Heating", "Baxi", "Megaflo System", "24 HE A", "GC No 41-075-57", "2008", "2015", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24", "24", "", "", "88.3", "79.3", "", "58.0", "", "2", "", "", "102", "1", "2", "150", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.9", "96.9", "", "", "", "", "95.5"]} +{"pcdb_id": 15692, "brand_name": "Baxi", "model_name": "Megaflo System", "model_qualifier": "28 HE A", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 28.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015692", "000005", "0", "2015/Aug/06 11:48", "Baxi Heating", "Baxi", "Megaflo System", "28 HE A", "GC No 41-075-58", "2008", "2015", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "28", "28", "", "", "88.3", "79.3", "", "57.9", "", "2", "", "", "102", "1", "2", "160", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.9", "96.7", "", "", "", "", "95.4"]} +{"pcdb_id": 15693, "brand_name": "Baxi", "model_name": "Megaflo System", "model_qualifier": "32 HE A", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 32.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015693", "000005", "0", "2015/Aug/06 11:49", "Baxi Heating", "Baxi", "Megaflo System", "32 HE A", "GC No. 41-075-59", "2008", "2015", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "32", "32", "", "", "88.3", "79.3", "", "57.9", "", "2", "", "", "102", "1", "2", "160", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.9", "96.7", "", "", "", "", "95.4"]} +{"pcdb_id": 15694, "brand_name": "Baxi", "model_name": "Platinum Combi", "model_qualifier": "24 HE A", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 56.1, "output_kw_max": 24.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015694", "000005", "0", "2015/Aug/06 11:49", "Baxi Heating", "Baxi", "Platinum Combi", "24 HE A", "GC No 47-075-31", "2008", "2015", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "88.4", "79.8", "", "56.1", "", "2", "", "", "104", "1", "2", "155", "5", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "90.0", "96.9", "", "", "", "", "95.6"]} +{"pcdb_id": 15695, "brand_name": "Baxi", "model_name": "Platinum Combi", "model_qualifier": "28 HE A", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 56.1, "output_kw_max": 24.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015695", "000005", "0", "2015/Aug/06 11:51", "Baxi Heating", "Baxi", "Platinum Combi", "28 HE A", "GC No 47-075-32", "2008", "2015", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "88.4", "79.8", "", "56.1", "", "2", "", "", "104", "1", "2", "155", "5", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "90.0", "96.9", "", "", "", "", "95.6"]} +{"pcdb_id": 15696, "brand_name": "Baxi", "model_name": "Platinum Combi", "model_qualifier": "33 HE A", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 56.0, "output_kw_max": 28.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015696", "000005", "0", "2015/Aug/06 11:51", "Baxi Heating", "Baxi", "Platinum Combi", "33 HE A", "GC No 47-075-33", "2008", "2015", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28", "28", "", "", "88.3", "79.7", "", "56.0", "", "2", "", "", "104", "1", "2", "160", "5", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "90.0", "96.7", "", "", "", "", "95.4"]} +{"pcdb_id": 15697, "brand_name": "Baxi", "model_name": "Platinum Combi", "model_qualifier": "40 HE A", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 56.0, "output_kw_max": 32.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015697", "000005", "0", "2015/Aug/06 11:52", "Baxi Heating", "Baxi", "Platinum Combi", "40 HE A", "GC No 47-075-34", "2008", "2015", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "32", "32", "", "", "88.3", "79.7", "", "56.0", "", "2", "", "", "104", "1", "2", "160", "5", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "90.0", "96.7", "", "", "", "", "95.4"]} +{"pcdb_id": 15700, "brand_name": "Main", "model_name": "Combi", "model_qualifier": "30 Eco", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 55.9, "output_kw_max": 28.63, "final_year_of_manufacture": 2012, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015700", "000005", "0", "2015/Aug/06 13:10", "Baxi Heating", "Main", "Combi", "30 Eco", "GC No. 47-467-03", "2008", "2012", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28.63", "28.63", "", "", "88.1", "79.5", "", "55.9", "", "2", "", "", "104", "1", "2", "150", "6", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "97.0", "", "", "", "", "95.3"]} +{"pcdb_id": 15701, "brand_name": "Main", "model_name": "Combi", "model_qualifier": "25 Eco", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 56.1, "output_kw_max": 25.94, "final_year_of_manufacture": 2012, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015701", "000005", "0", "2013/May/07 10:33", "Baxi Heating", "Main", "Combi", "25 Eco", "GC No. 47-467-01", "2008", "2012", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "25.94", "25.94", "", "", "88.4", "79.8", "", "56.1", "", "2", "", "", "104", "1", "2", "150", "8", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.7", "97.0", "", "", "", "", "95.7"]} +{"pcdb_id": 15702, "brand_name": "Main", "model_name": "System", "model_qualifier": "28 Eco", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 28.63, "final_year_of_manufacture": 2012, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015702", "000005", "0", "2013/May/07 10:34", "Baxi Heating", "Main", "System", "28 Eco", "GC No. 41-467-12", "2008", "2012", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "28.63", "28.63", "", "", "88.1", "79.1", "", "57.8", "", "2", "", "", "102", "1", "2", "150", "8", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "97.0", "", "", "", "", "95.3"]} +{"pcdb_id": 15703, "brand_name": "Main", "model_name": "System", "model_qualifier": "24 Eco", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 25.94, "final_year_of_manufacture": 2012, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015703", "000005", "0", "2013/May/07 10:34", "Baxi Heating", "Main", "System", "24 Eco", "GC No. 41-467-11", "2008", "2012", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "25.94", "25.94", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "150", "8", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.7", "97.0", "", "", "", "", "95.7"]} +{"pcdb_id": 15704, "brand_name": "Baxi", "model_name": "Duo-tec Combi", "model_qualifier": "40 HE A", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 56.0, "output_kw_max": 32.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015704", "000005", "0", "2015/Aug/06 11:53", "Baxi Heating", "Baxi", "Duo-tec Combi", "40 HE A", "GC No 47-075-38", "2008", "2015", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "32", "32", "", "", "88.3", "79.7", "", "56.0", "", "2", "", "", "104", "1", "2", "160", "5", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "90.0", "96.7", "", "", "", "", "95.4"]} +{"pcdb_id": 15705, "brand_name": "Baxi", "model_name": "Duo-tec Combi", "model_qualifier": "33 HE A", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 56.0, "output_kw_max": 28.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015705", "000005", "0", "2015/Aug/06 11:53", "Baxi Heating", "Baxi", "Duo-tec Combi", "33 HE A", "GC No. 47-075-37", "2008", "2015", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28", "28", "", "", "88.3", "79.7", "", "56.0", "", "2", "", "", "104", "1", "2", "160", "5", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "90.0", "96.7", "", "", "", "", "95.4"]} +{"pcdb_id": 15706, "brand_name": "Baxi", "model_name": "Duo-tec Combi", "model_qualifier": "28 HE A", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 56.1, "output_kw_max": 24.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015706", "000005", "0", "2015/Aug/06 11:54", "Baxi Heating", "Baxi", "Duo-tec Combi", "28 HE A", "GC No. 47-075-36", "2007", "2015", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "88.4", "79.8", "", "56.1", "", "2", "", "", "104", "1", "2", "155", "5", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "90.0", "96.9", "", "", "", "", "95.6"]} +{"pcdb_id": 15707, "brand_name": "Baxi", "model_name": "Duo-tec Combi", "model_qualifier": "24 HE A", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 56.1, "output_kw_max": 20.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015707", "000005", "0", "2015/Aug/06 11:55", "Baxi Heating", "Baxi", "Duo-tec Combi", "24 HE A", "GC No. 47-075-35", "2008", "2015", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "20.0", "20.0", "", "", "88.4", "79.8", "", "56.1", "", "2", "", "", "104", "1", "2", "155", "5", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "90.0", "96.9", "", "", "", "", "95.6"]} +{"pcdb_id": 15708, "brand_name": "Potterton", "model_name": "Promax Combi", "model_qualifier": "33 HE Plus A", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 56.0, "output_kw_max": 28.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015708", "000005", "0", "2015/Aug/06 12:52", "Baxi Heating", "Potterton", "Promax Combi", "33 HE Plus A", "GC No. 47-393-23", "2008", "2015", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28", "28", "", "", "88.3", "79.7", "", "56.0", "", "2", "", "", "104", "1", "2", "160", "5", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "90.0", "96.7", "", "", "", "", "95.4"]} +{"pcdb_id": 15709, "brand_name": "Potterton", "model_name": "Promax Combi", "model_qualifier": "28 HE Plus A", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 56.1, "output_kw_max": 24.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015709", "000005", "0", "2015/Aug/06 12:52", "Baxi Heating", "Potterton", "Promax Combi", "28 HE Plus A", "GC No 47-393-22", "2008", "2015", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "88.4", "79.8", "", "56.1", "", "2", "", "", "104", "1", "2", "155", "5", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "90.0", "96.9", "", "", "", "", "95.6"]} +{"pcdb_id": 15710, "brand_name": "Potterton", "model_name": "Promax Combi", "model_qualifier": "24 HE Plus A", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 56.1, "output_kw_max": 20.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015710", "000005", "0", "2015/Aug/06 12:53", "Baxi Heating", "Potterton", "Promax Combi", "24 HE Plus A", "GC No. 47-393-21", "2008", "2015", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "20", "20", "", "", "88.4", "79.8", "", "56.1", "", "2", "", "", "104", "1", "2", "155", "5", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "90.0", "96.9", "", "", "", "", "95.6"]} +{"pcdb_id": 15711, "brand_name": "ATAG", "model_name": "Q25SC", "model_qualifier": "", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 21.9, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015711", "000227", "0", "2013/Oct/23 12:58", "ATAG Verwarming Nederland BV", "ATAG", "Q25SC", "", "GC No. 41-310-08", "2007", "current", "1", "1", "1", "1", "0", "", "", "2", "3", "2", "21.9", "21.9", "", "", "88.9", "79.9", "", "58.3", "", "2", "", "", "102", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.2", "98.9", "", "", "", "", "96.9"]} +{"pcdb_id": 15712, "brand_name": "ATAG", "model_name": "Q38SC", "model_qualifier": "", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 33.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015712", "000227", "0", "2013/Oct/23 12:58", "ATAG Verwarming Nederland BV", "ATAG", "Q38SC", "", "GC No. 41-310-09", "2007", "current", "1", "1", "1", "1", "0", "", "", "2", "3", "2", "33.3", "33.3", "", "", "88.7", "79.7", "", "58.3", "", "2", "", "", "102", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "98.7", "", "", "", "", "96.7"]} +{"pcdb_id": 15714, "brand_name": "Gerkros", "model_name": "14.6 - 20.5 kW Oil Condensing Combi Boiler", "model_qualifier": "", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 56.6, "output_kw_max": 20.69, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015714", "000245", "0", "2008/Feb/06 12:54", "Gerkros Boilers (Tipperary) Limited", "Gerkros", "14.6 - 20.5 kW Oil Condensing Combi Boiler", "", "", "2007", "current", "4", "1", "2", "2", "0", "", "", "2", "3", "1", "14.65", "20.69", "", "", "87.9", "80.5", "", "56.6", "", "2", "", "", "202", "1", "1", "250", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.3", "94.4", "", "", "", "", "93.8"]} +{"pcdb_id": 15716, "brand_name": "Gerkros", "model_name": "20.5 - 26.4 kW Oil Condensing Combi Boiler", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 80.6, "comparative_hot_water_efficiency_pct": 56.7, "output_kw_max": 27.06, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015716", "000245", "0", "2008/Feb/06 12:53", "Gerkros Boilers (Tipperary) Limited", "Gerkros", "20.5 - 26.4 kW Oil Condensing Combi Boiler", "", "", "2007", "current", "4", "1", "2", "2", "0", "", "", "2", "3", "1", "20.69", "27.06", "", "", "88.0", "80.6", "", "56.7", "", "2", "", "", "202", "1", "1", "250", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.9", "94.7", "", "", "", "", "94.0"]} +{"pcdb_id": 15717, "brand_name": "Warmflow", "model_name": "Kabin Pak", "model_qualifier": "KP150HE", "winter_efficiency_pct": 87.5, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 44.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015717", "000063", "0", "2013/Mar/28 08:29", "Warmflow Engineering", "Warmflow", "Kabin Pak", "KP150HE", "", "2008", "current", "4", "1", "2", "1", "0", "", "", "2", "1", "2", "33", "44", "", "", "87.5", "79.7", "", "58.2", "", "2", "", "", "201", "1", "1", "230", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "89.6", "94.1", "", "", "", "", "93.2"]} +{"pcdb_id": 15718, "brand_name": "Warmflow", "model_name": "Kabin Pak", "model_qualifier": "K150HE", "winter_efficiency_pct": 87.5, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 44.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015718", "000063", "0", "2013/Mar/28 08:29", "Warmflow Engineering", "Warmflow", "Kabin Pak", "K150HE", "", "2008", "current", "4", "1", "2", "1", "0", "", "", "2", "1", "2", "33", "44", "", "", "87.5", "79.7", "", "58.2", "", "2", "", "", "201", "1", "1", "160", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "89.6", "94.1", "", "", "", "", "93.2"]} +{"pcdb_id": 15719, "brand_name": "Warmflow", "model_name": "Utility", "model_qualifier": "UP150HE", "winter_efficiency_pct": 87.5, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 44.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015719", "000063", "0", "2013/Mar/28 08:29", "Warmflow Engineering", "Warmflow", "Utility", "UP150HE", "", "2008", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "33", "44", "", "", "87.5", "79.7", "", "58.2", "", "2", "", "", "201", "1", "1", "230", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "89.6", "94.1", "", "", "", "", "93.2"]} +{"pcdb_id": 15721, "brand_name": "Fondital", "model_name": "Tahiti Condensing KRB 32 Line Tech", "model_qualifier": "", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 78.9, "comparative_hot_water_efficiency_pct": 57.6, "output_kw_max": 30.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015721", "000250", "0", "2012/Mar/27 10:12", "Fondital SpA", "Fondital", "Tahiti Condensing KRB 32 Line Tech", "", "", "2007", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "30.6", "30.6", "", "", "87.9", "78.9", "", "57.6", "", "2", "", "", "102", "1", "2", "155", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "96.6", "", "", "", "", "94.9"]} +{"pcdb_id": 15722, "brand_name": "Fondital", "model_name": "Tahiti Condensing KRB 32 Line Tech", "model_qualifier": "", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 30.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015722", "000250", "0", "2012/Mar/27 10:12", "Fondital SpA", "Fondital", "Tahiti Condensing KRB 32 Line Tech", "", "", "2007", "current", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "30.6", "30.6", "", "", "88.9", "79.9", "", "58.4", "", "2", "1", "", "102", "1", "2", "155", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.9", "98.7", "", "", "", "", "97.1"]} +{"pcdb_id": 15723, "brand_name": "Fondital", "model_name": "Tahiti Condensing KRB 28 Line Tech", "model_qualifier": "", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 78.9, "comparative_hot_water_efficiency_pct": 57.6, "output_kw_max": 25.55, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015723", "000250", "0", "2012/Mar/27 10:12", "Fondital SpA", "Fondital", "Tahiti Condensing KRB 28 Line Tech", "", "", "2007", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "25.55", "25.55", "", "", "87.9", "78.9", "", "57.6", "", "2", "", "", "102", "1", "2", "155", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "96.5", "", "", "", "", "94.9"]} +{"pcdb_id": 15724, "brand_name": "Fondital", "model_name": "Tahiti Condensing KRB 28 Line Tech", "model_qualifier": "", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 25.55, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015724", "000250", "0", "2012/Mar/27 10:12", "Fondital SpA", "Fondital", "Tahiti Condensing KRB 28 Line Tech", "", "", "2007", "current", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "25.55", "25.55", "", "", "88.9", "79.9", "", "58.3", "", "2", "1", "", "102", "1", "2", "155", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.8", "98.6", "", "", "", "", "97.0"]} +{"pcdb_id": 15725, "brand_name": "Fondital", "model_name": "Tahiti Condensing KRB 24 Line Tech", "model_qualifier": "", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 78.9, "comparative_hot_water_efficiency_pct": 57.6, "output_kw_max": 23.1, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015725", "000250", "0", "2012/Mar/27 10:12", "Fondital SpA", "Fondital", "Tahiti Condensing KRB 24 Line Tech", "", "", "2007", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "23.1", "23.1", "", "", "87.9", "78.9", "", "57.6", "", "2", "", "", "102", "1", "2", "155", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "96.5", "", "", "", "", "94.9"]} +{"pcdb_id": 15726, "brand_name": "Fondital", "model_name": "Tahiti Condensing KRB 24 Line Tech", "model_qualifier": "", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 23.1, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015726", "000250", "0", "2012/Mar/27 10:12", "Fondital SpA", "Fondital", "Tahiti Condensing KRB 24 Line Tech", "", "", "2007", "current", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "23.1", "23.1", "", "", "88.9", "79.9", "", "58.3", "", "2", "1", "", "102", "1", "2", "155", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.8", "98.6", "", "", "", "", "97.0"]} +{"pcdb_id": 15727, "brand_name": "Fondital", "model_name": "Tahiti Condensing KR 32 Line Tech", "model_qualifier": "", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 78.9, "comparative_hot_water_efficiency_pct": 57.6, "output_kw_max": 30.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015727", "000250", "0", "2012/Mar/27 10:12", "Fondital SpA", "Fondital", "Tahiti Condensing KR 32 Line Tech", "", "", "2006", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "30.6", "30.6", "", "", "87.9", "78.9", "", "57.6", "", "2", "", "", "102", "1", "2", "155", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "96.6", "", "", "", "", "94.9"]} +{"pcdb_id": 15728, "brand_name": "Fondital", "model_name": "Tahiti Condensing KR 32 Line Tech", "model_qualifier": "", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 30.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015728", "000250", "0", "2012/Mar/27 10:12", "Fondital SpA", "Fondital", "Tahiti Condensing KR 32 Line Tech", "", "", "2006", "current", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "30.6", "30.6", "", "", "88.9", "79.9", "", "58.4", "", "2", "1", "", "102", "1", "2", "155", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.9", "98.7", "", "", "", "", "97.1"]} +{"pcdb_id": 15729, "brand_name": "Fondital", "model_name": "Tahiti Condensing KR 28 Line Tech", "model_qualifier": "", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 78.9, "comparative_hot_water_efficiency_pct": 57.6, "output_kw_max": 25.55, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015729", "000250", "0", "2012/Mar/27 10:12", "Fondital SpA", "Fondital", "Tahiti Condensing KR 28 Line Tech", "", "", "2007", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "25.55", "25.55", "", "", "87.9", "78.9", "", "57.6", "", "2", "", "", "102", "1", "2", "155", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "96.5", "", "", "", "", "94.9"]} +{"pcdb_id": 15730, "brand_name": "Fondital", "model_name": "Tahiti Condensing KR 28 Line Tech", "model_qualifier": "", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 25.55, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015730", "000250", "0", "2012/Mar/27 10:12", "Fondital SpA", "Fondital", "Tahiti Condensing KR 28 Line Tech", "", "", "2007", "current", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "25.55", "25.55", "", "", "88.9", "79.9", "", "58.3", "", "2", "1", "", "102", "1", "2", "155", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.8", "98.6", "", "", "", "", "97.0"]} +{"pcdb_id": 15731, "brand_name": "Fondital", "model_name": "Tahiti Condensing KR 24 Line Tech", "model_qualifier": "", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 78.9, "comparative_hot_water_efficiency_pct": 57.6, "output_kw_max": 23.1, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015731", "000250", "0", "2012/Mar/27 10:12", "Fondital SpA", "Fondital", "Tahiti Condensing KR 24 Line Tech", "", "", "2006", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "23.1", "23.1", "", "", "87.9", "78.9", "", "57.6", "", "2", "", "", "102", "1", "2", "155", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "96.5", "", "", "", "", "94.9"]} +{"pcdb_id": 15732, "brand_name": "Fondital", "model_name": "Tahiti Condensing KR 24 Line Tech", "model_qualifier": "", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 23.1, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015732", "000250", "0", "2012/Mar/27 10:12", "Fondital SpA", "Fondital", "Tahiti Condensing KR 24 Line Tech", "", "", "2006", "current", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "23.1", "23.1", "", "", "88.9", "79.9", "", "58.3", "", "2", "1", "", "102", "1", "2", "155", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.8", "98.6", "", "", "", "", "97.0"]} +{"pcdb_id": 15733, "brand_name": "Fondital", "model_name": "Tahiti Condensing KC 32 Line Tech", "model_qualifier": "", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 55.8, "output_kw_max": 30.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015733", "000250", "0", "2008/Feb/29 10:31", "Fondital SpA", "Fondital", "Tahiti Condensing KC 32 Line Tech", "", "", "2006", "current", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "30.6", "30.6", "", "", "87.9", "79.3", "", "55.8", "", "2", "", "", "104", "1", "2", "155", "10", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "96.6", "", "", "", "", "94.9"]} +{"pcdb_id": 15734, "brand_name": "Fondital", "model_name": "Tahiti Condensing KC 32 Line Tech", "model_qualifier": "", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 56.5, "output_kw_max": 30.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015734", "000250", "0", "2008/Feb/29 10:31", "Fondital SpA", "Fondital", "Tahiti Condensing KC 32 Line Tech", "", "", "2006", "current", "2", "2", "1", "2", "0", "", "", "2", "3", "2", "30.6", "30.6", "", "", "88.9", "80.3", "", "56.5", "", "2", "1", "", "104", "1", "2", "155", "10", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.9", "98.7", "", "", "", "", "97.1"]} +{"pcdb_id": 15735, "brand_name": "Fondital", "model_name": "Tahiti Condensing KC 28 Line Tech", "model_qualifier": "", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 55.7, "output_kw_max": 25.55, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015735", "000250", "0", "2008/Feb/29 10:31", "Fondital SpA", "Fondital", "Tahiti Condensing KC 28 Line Tech", "", "", "2007", "current", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "25.55", "25.55", "", "", "87.9", "79.3", "", "55.7", "", "2", "", "", "104", "1", "2", "155", "10", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "96.5", "", "", "", "", "94.9"]} +{"pcdb_id": 15736, "brand_name": "Fondital", "model_name": "Tahiti Condensing KC 28 Line Tech", "model_qualifier": "", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 56.4, "output_kw_max": 25.55, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015736", "000250", "0", "2008/Feb/29 10:31", "Fondital SpA", "Fondital", "Tahiti Condensing KC 28 Line Tech", "", "", "2007", "current", "2", "2", "1", "2", "0", "", "", "2", "3", "2", "25.55", "25.55", "", "", "88.9", "80.3", "", "56.4", "", "2", "1", "", "104", "1", "2", "155", "10", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.8", "98.6", "", "", "", "", "97.0"]} +{"pcdb_id": 15737, "brand_name": "Fondital", "model_name": "Tahiti Condensing KC 24 Line Tech", "model_qualifier": "", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 55.7, "output_kw_max": 23.1, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015737", "000250", "0", "2008/Feb/29 10:31", "Fondital SpA", "Fondital", "Tahiti Condensing KC 24 Line Tech", "", "", "2006", "current", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "23.1", "23.1", "", "", "87.9", "79.3", "", "55.7", "", "2", "", "", "104", "1", "2", "155", "10", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "96.5", "", "", "", "", "94.9"]} +{"pcdb_id": 15738, "brand_name": "Fondital", "model_name": "Tahiti Condensing KC 24 Line Tech", "model_qualifier": "", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 56.4, "output_kw_max": 23.1, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015738", "000250", "0", "2008/Feb/29 10:31", "Fondital SpA", "Fondital", "Tahiti Condensing KC 24 Line Tech", "", "", "2006", "current", "2", "2", "1", "2", "0", "", "", "2", "3", "2", "23.1", "23.1", "", "", "88.9", "80.3", "", "56.4", "", "2", "1", "", "104", "1", "2", "155", "10", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.8", "98.6", "", "", "", "", "97.0"]} +{"pcdb_id": 15740, "brand_name": "Biasi", "model_name": "Riva Advance HE", "model_qualifier": "M110B.24SM/C", "winter_efficiency_pct": 89.5, "summer_efficiency_pct": 80.9, "comparative_hot_water_efficiency_pct": 56.9, "output_kw_max": 25.1, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015740", "000208", "0", "2008/Jun/26 09:42", "Biasi SpA", "Biasi", "Riva Advance HE", "M110B.24SM/C", "47-583-11", "2007", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "5.8", "25.1", "", "", "89.5", "80.9", "", "56.9", "", "2", "1", "", "104", "1", "2", "108", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.1", "100.1", "", "", "", "", "98.2"]} +{"pcdb_id": 15741, "brand_name": "Biasi", "model_name": "Riva Advance HE", "model_qualifier": "M110B.24SM/C", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 56.2, "output_kw_max": 25.1, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015741", "000208", "0", "2013/Feb/27 12:39", "Biasi SpA", "Biasi", "Riva Advance HE", "M110B.24SM/C", "47-583-11", "2007", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "25.1", "25.1", "", "", "88.5", "79.9", "", "56.2", "", "2", "", "", "104", "1", "2", "108", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.1", "97.9", "", "", "", "", "96.1"]} +{"pcdb_id": 15742, "brand_name": "Biasi", "model_name": "Riva Advance HE", "model_qualifier": "M110B.32SM/C", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 56.5, "output_kw_max": 33.1, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015742", "000208", "0", "2008/Jun/26 09:42", "Biasi SpA", "Biasi", "Riva Advance HE", "M110B.32SM/C", "47-583-12", "2007", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "33.1", "33.1", "", "", "88.9", "80.3", "", "56.5", "", "2", "1", "", "104", "1", "2", "125", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.7", "98.9", "", "", "", "", "97.2"]} +{"pcdb_id": 15743, "brand_name": "Biasi", "model_name": "Riva Advance HE", "model_qualifier": "M110B.32SM/C", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 55.8, "output_kw_max": 33.1, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015743", "000208", "0", "2013/Feb/27 12:41", "Biasi SpA", "Biasi", "Riva Advance HE", "M110B.32SM/C", "47-583-12", "2007", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "33.1", "33.1", "", "", "88.0", "79.4", "", "55.8", "", "2", "", "", "104", "1", "2", "125", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "96.8", "", "", "", "", "95.1"]} +{"pcdb_id": 15744, "brand_name": "Biasi", "model_name": "Garda Plus HE", "model_qualifier": "M110B.24SM/E", "winter_efficiency_pct": 89.5, "summer_efficiency_pct": 80.9, "comparative_hot_water_efficiency_pct": 56.9, "output_kw_max": 25.1, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015744", "000208", "0", "2008/Jun/26 09:42", "Biasi SpA", "Biasi", "Garda Plus HE", "M110B.24SM/E", "47-583-13", "2007", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "5.8", "25.1", "", "", "89.5", "80.9", "", "56.9", "", "2", "1", "", "104", "1", "2", "108", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.1", "100.1", "", "", "", "", "98.2"]} +{"pcdb_id": 15745, "brand_name": "Biasi", "model_name": "Garda Plus HE", "model_qualifier": "M110B.24SM/E", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 56.2, "output_kw_max": 25.1, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015745", "000208", "0", "2008/Jun/26 09:41", "Biasi SpA", "Biasi", "Garda Plus HE", "M110B.24SM/E", "47-583-13", "2007", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "5.8", "25.1", "", "", "88.5", "79.9", "", "56.2", "", "2", "", "", "104", "1", "2", "108", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.1", "97.9", "", "", "", "", "96.1"]} +{"pcdb_id": 15746, "brand_name": "Biasi", "model_name": "Garda Plus HE", "model_qualifier": "M110B.32SM/E", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 56.5, "output_kw_max": 33.1, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015746", "000208", "0", "2008/Jun/26 09:42", "Biasi SpA", "Biasi", "Garda Plus HE", "M110B.32SM/E", "47-583-14", "2007", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "8.2", "33.1", "", "", "88.9", "80.3", "", "56.5", "", "2", "1", "", "104", "1", "2", "125", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.7", "98.9", "", "", "", "", "97.2"]} +{"pcdb_id": 15747, "brand_name": "Biasi", "model_name": "Garda Plus HE", "model_qualifier": "M110B.32SM/E", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 55.8, "output_kw_max": 33.1, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015747", "000208", "0", "2008/Jun/26 09:41", "Biasi SpA", "Biasi", "Garda Plus HE", "M110B.32SM/E", "47-583-14", "2007", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "8.2", "33.1", "", "", "88.0", "79.4", "", "55.8", "", "2", "", "", "104", "1", "2", "125", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "96.8", "", "", "", "", "95.1"]} +{"pcdb_id": 15748, "brand_name": "British Gas", "model_name": "330+", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 30.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015748", "000207", "0", "2012/Mar/27 10:12", "Vaillant Group UK", "British Gas", "330+", "", "41-019-11", "2008", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "30.00", "30.00", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "60", "6", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.8", "96.4", "", "", "", "", "95.0"]} +{"pcdb_id": 15749, "brand_name": "Scottish Gas", "model_name": "330+", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 30.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015749", "000207", "0", "2012/Mar/27 10:12", "Vaillant Group UK", "Scottish Gas", "330+", "", "", "2008", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "30.00", "30.00", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "60", "6", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.8", "96.4", "", "", "", "", "95.0"]} +{"pcdb_id": 15751, "brand_name": "Potterton", "model_name": "Gold", "model_qualifier": "24 HE A", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 56.1, "output_kw_max": 20.5, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015751", "000005", "0", "2015/Aug/06 12:53", "Baxi Heating UK", "Potterton", "Gold", "24 HE A", "GC No. 47-393-18", "2008", "2015", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "20.5", "20.5", "", "", "88.4", "79.8", "", "56.1", "", "2", "", "", "104", "1", "2", "155", "5", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "90.0", "96.9", "", "", "", "", "95.6"]} +{"pcdb_id": 15752, "brand_name": "Potterton", "model_name": "Gold", "model_qualifier": "28 HE A", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 56.1, "output_kw_max": 24.7, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015752", "000005", "0", "2015/Aug/06 12:54", "Baxi Heating UK", "Potterton", "Gold", "28 HE A", "GC No. 47-393-19", "2008", "2015", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.7", "24.7", "", "", "88.4", "79.8", "", "56.1", "", "2", "", "", "104", "1", "2", "155", "5", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "90.0", "96.9", "", "", "", "", "95.6"]} +{"pcdb_id": 15753, "brand_name": "Potterton", "model_name": "Gold", "model_qualifier": "33 HE A", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 56.0, "output_kw_max": 28.9, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015753", "000005", "0", "2015/Aug/06 12:54", "Baxi Heating UK", "Potterton", "Gold", "33 HE A", "GC No 47-393-20", "2008", "2015", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28.9", "28.9", "", "", "88.3", "79.7", "", "56.0", "", "2", "", "", "104", "1", "2", "160", "5", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "90.0", "96.7", "", "", "", "", "95.4"]} +{"pcdb_id": 15754, "brand_name": "Potterton", "model_name": "Promax System", "model_qualifier": "12 HE Plus A", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 12.4, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015754", "000005", "0", "2015/Aug/06 12:55", "Baxi Heating UK", "Potterton", "Promax System", "12 HE Plus A", "GC No. 41-591-99", "2008", "2015", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "12.4", "12.4", "", "", "88.3", "79.3", "", "57.9", "", "2", "", "", "102", "1", "2", "145", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.9", "96.7", "", "", "", "", "95.4"]} +{"pcdb_id": 15755, "brand_name": "Potterton", "model_name": "Promax System", "model_qualifier": "15 HE Plus A", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 15.4, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015755", "000005", "0", "2015/Aug/06 12:56", "Baxi Heating UK", "Potterton", "Promax System", "15 HE Plus A", "GC No. 41-592-01", "2008", "2015", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "15.4", "15.4", "", "", "88.3", "79.3", "", "57.9", "", "2", "", "", "102", "1", "2", "130", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.9", "96.8", "", "", "", "", "95.5"]} +{"pcdb_id": 15756, "brand_name": "Potterton", "model_name": "Promax System", "model_qualifier": "18 HE Plus A", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 18.5, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015756", "000005", "0", "2015/Aug/06 12:56", "Baxi Heating UK", "Potterton", "Promax System", "18 HE Plus A", "GC NO. 41-592-02", "2008", "2015", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18.5", "18.5", "", "", "88.3", "79.3", "", "58.0", "", "2", "", "", "102", "1", "2", "140", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.9", "96.9", "", "", "", "", "95.5"]} +{"pcdb_id": 15757, "brand_name": "Potterton", "model_name": "Promax System", "model_qualifier": "24 HE Plus A", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 24.7, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015757", "000005", "0", "2015/Aug/06 12:57", "Baxi Heating UK", "Potterton", "Promax System", "24 HE Plus A", "GC No. 41-592-03", "2008", "2015", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24.7", "24.7", "", "", "88.3", "79.3", "", "58.0", "", "2", "", "", "102", "1", "2", "150", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.9", "96.9", "", "", "", "", "95.5"]} +{"pcdb_id": 15758, "brand_name": "Potterton", "model_name": "Promax System", "model_qualifier": "32 HE Plus A", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 32.8, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015758", "000005", "0", "2015/Aug/06 12:57", "Baxi Heating UK", "Potterton", "Promax System", "32 HE Plus A", "GC No. 41-592-04", "2008", "2015", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "32.8", "32.8", "", "", "88.3", "79.3", "", "57.9", "", "2", "", "", "102", "1", "2", "160", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.9", "96.7", "", "", "", "", "95.4"]} +{"pcdb_id": 15759, "brand_name": "Potterton", "model_name": "Performa", "model_qualifier": "9 SL HE", "winter_efficiency_pct": 84.0, "summer_efficiency_pct": 76.4, "comparative_hot_water_efficiency_pct": 55.8, "output_kw_max": 8.82, "final_year_of_manufacture": 2011, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015759", "000005", "0", "2013/May/07 10:34", "Baxi Heating UK", "Potterton", "Performa", "9 SL HE", "GC No. 41-592-05", "2008", "2011", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "8.82", "8.82", "", "", "84.0", "76.4", "", "55.8", "", "2", "", "", "101", "1", "1", "80", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "86.3", "90.9", "", "", "", "", "90.0"]} +{"pcdb_id": 15760, "brand_name": "Potterton", "model_name": "Performa", "model_qualifier": "12 SL HE", "winter_efficiency_pct": 84.2, "summer_efficiency_pct": 76.6, "comparative_hot_water_efficiency_pct": 55.9, "output_kw_max": 11.78, "final_year_of_manufacture": 2011, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015760", "000005", "0", "2013/May/07 10:35", "Baxi Heating UK", "Potterton", "Performa", "12 SL HE", "GC No. 41-592-06", "2008", "2011", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "11.78", "11.78", "", "", "84.2", "76.6", "", "55.9", "", "2", "", "", "101", "1", "1", "80", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "86.5", "91.3", "", "", "", "", "90.4"]} +{"pcdb_id": 15761, "brand_name": "Potterton", "model_name": "Performa", "model_qualifier": "15 SL HE", "winter_efficiency_pct": 84.0, "summer_efficiency_pct": 76.4, "comparative_hot_water_efficiency_pct": 55.8, "output_kw_max": 14.76, "final_year_of_manufacture": 2011, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015761", "000005", "0", "2013/May/07 10:35", "Baxi Heating UK", "Potterton", "Performa", "15 SL HE", "GC No. 41-592-07", "2008", "2011", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "14.76", "14.76", "", "", "84.0", "76.4", "", "55.8", "", "2", "", "", "101", "1", "1", "80", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "86.7", "90.7", "", "", "", "", "90.0"]} +{"pcdb_id": 15762, "brand_name": "Potterton", "model_name": "Performa", "model_qualifier": "18 SL HE", "winter_efficiency_pct": 84.0, "summer_efficiency_pct": 76.4, "comparative_hot_water_efficiency_pct": 55.8, "output_kw_max": 17.72, "final_year_of_manufacture": 2011, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015762", "000005", "0", "2013/May/07 10:35", "Baxi Heating UK", "Potterton", "Performa", "18 SL HE", "GC No. 41-592-08", "2008", "2011", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "17.72", "17.72", "", "", "84.0", "76.4", "", "55.8", "", "2", "", "", "101", "1", "1", "80", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "86.8", "90.6", "", "", "", "", "89.9"]} +{"pcdb_id": 15763, "brand_name": "Potterton", "model_name": "Performa", "model_qualifier": "21 SL HE", "winter_efficiency_pct": 84.0, "summer_efficiency_pct": 76.4, "comparative_hot_water_efficiency_pct": 55.8, "output_kw_max": 20.68, "final_year_of_manufacture": 2011, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015763", "000005", "0", "2013/May/07 10:35", "Baxi Heating UK", "Potterton", "Performa", "21 SL HE", "GC No. 41-592-09", "2008", "2011", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "20.68", "20.68", "", "", "84.0", "76.4", "", "55.8", "", "2", "", "", "101", "1", "1", "80", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "86.8", "90.7", "", "", "", "", "90.0"]} +{"pcdb_id": 15764, "brand_name": "Potterton", "model_name": "Performa", "model_qualifier": "24 SL HE", "winter_efficiency_pct": 84.0, "summer_efficiency_pct": 76.4, "comparative_hot_water_efficiency_pct": 55.8, "output_kw_max": 23.63, "final_year_of_manufacture": 2011, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015764", "000005", "0", "2013/May/07 10:35", "Baxi Heating UK", "Potterton", "Performa", "24 SL HE", "GC No. 41-592-10", "2008", "2011", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "23.63", "23.63", "", "", "84.0", "76.4", "", "55.8", "", "2", "", "", "101", "1", "1", "80", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "86.8", "90.6", "", "", "", "", "89.9"]} +{"pcdb_id": 15766, "brand_name": "Glow-worm", "model_name": "Flexicom 35cx", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 56.2, "output_kw_max": 30.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015766", "000207", "0", "2010/Oct/22 10:40", "Vaillant Group", "Glow-worm", "Flexicom 35cx", "", "GC 47-047-35", "2008", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "30.0", "30.0", "", "", "88.5", "79.9", "", "56.2", "", "2", "", "", "104", "1", "2", "180", "6", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0085", "", "", "", "", "", "", "", "", "88.1", "98.0", "", "", "", "", "96.1"]} +{"pcdb_id": 15767, "brand_name": "Glow-worm", "model_name": "Flexicom 35hx", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 35.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015767", "000207", "0", "2012/Mar/27 10:12", "Vaillant Group", "Glow-worm", "Flexicom 35hx", "", "GC 41-315-68", "2008", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "35.0", "35.0", "", "", "88.5", "79.5", "", "58.1", "", "2", "", "", "102", "1", "2", "60", "6", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0085", "", "", "", "", "", "", "", "", "88.1", "98.0", "", "", "", "", "96.1"]} +{"pcdb_id": 15768, "brand_name": "Sime", "model_name": "Murelle HE", "model_qualifier": "12 System", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 11.7, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015768", "000213", "0", "2018/Mar/05 16:39", "Fonderie Sime S.p.A.", "Sime", "Murelle HE", "12 System", "", "2008", "2018", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "11.7", "11.7", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "110", "8", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.2", "96.6", "", "", "", "", "95.0"]} +{"pcdb_id": 15769, "brand_name": "Sime", "model_name": "Murelle HE", "model_qualifier": "12 System", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 11.7, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015769", "000213", "0", "2018/Mar/05 16:39", "Fonderie Sime S.p.A.", "Sime", "Murelle HE", "12 System", "", "2008", "2018", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "11.7", "11.7", "", "", "89.0", "80.0", "", "58.4", "", "2", "1", "", "102", "1", "2", "110", "8", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.2", "98.7", "", "", "", "", "97.1"]} +{"pcdb_id": 15770, "brand_name": "Sime", "model_name": "Murelle HE", "model_qualifier": "20 System", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 19.0, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015770", "000213", "0", "2018/Mar/05 16:41", "Fonderie Sime S.p.A.", "Sime", "Murelle HE", "20 System", "", "2008", "2018", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "19.0", "19.0", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "120", "8", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.2", "96.8", "", "", "", "", "95.1"]} +{"pcdb_id": 15771, "brand_name": "Sime", "model_name": "Murelle HE", "model_qualifier": "20 System", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 19.0, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015771", "000213", "0", "2018/Mar/05 16:41", "Fonderie Sime S.p.A.", "Sime", "Murelle HE", "20 System", "", "2008", "2018", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "19.0", "19.0", "", "", "89.0", "80.0", "", "58.5", "", "2", "1", "", "102", "1", "2", "120", "8", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.2", "98.9", "", "", "", "", "97.3"]} +{"pcdb_id": 15772, "brand_name": "Sime", "model_name": "Murelle HE", "model_qualifier": "25 System", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 23.9, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015772", "000213", "0", "2018/Mar/05 16:44", "Fonderie Sime S.p.A.", "Sime", "Murelle HE", "25 System", "", "2008", "2018", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "23.9", "23.9", "", "", "88.2", "79.2", "", "57.9", "", "2", "", "", "102", "1", "2", "125", "8", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.5", "97.1", "", "", "", "", "95.5"]} +{"pcdb_id": 15773, "brand_name": "Sime", "model_name": "Murelle HE", "model_qualifier": "25 System", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 23.9, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015773", "000213", "0", "2018/Mar/05 16:45", "Fonderie Sime S.p.A.", "Sime", "Murelle HE", "25 System", "", "2008", "2018", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "23.9", "23.9", "", "", "89.2", "80.2", "", "58.6", "", "2", "1", "", "102", "1", "2", "125", "8", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.4", "99.3", "", "", "", "", "97.6"]} +{"pcdb_id": 15774, "brand_name": "Sime", "model_name": "Murelle HE", "model_qualifier": "30 System", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 28.9, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015774", "000213", "0", "2018/Mar/05 16:52", "Fonderie Sime S.p.A.", "Sime", "Murelle HE", "30 System", "", "2008", "2018", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "28.9", "28.9", "", "", "88.2", "79.2", "", "57.9", "", "2", "", "", "102", "1", "2", "130", "8", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.7", "97.0", "", "", "", "", "95.4"]} +{"pcdb_id": 15775, "brand_name": "Sime", "model_name": "Murelle HE", "model_qualifier": "30 System", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 28.9, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015775", "000213", "0", "2018/Mar/05 16:53", "Fonderie Sime S.p.A.", "Sime", "Murelle HE", "30 System", "", "2008", "2018", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "28.9", "28.9", "", "", "89.2", "80.2", "", "58.6", "", "2", "1", "", "102", "1", "2", "130", "8", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.6", "99.2", "", "", "", "", "97.6"]} +{"pcdb_id": 15776, "brand_name": "Sime", "model_name": "Murelle HE", "model_qualifier": "35 System", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 34.1, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015776", "000213", "0", "2018/Mar/05 16:45", "Fonderie Sime S.p.A.", "Sime", "Murelle HE", "35 System", "", "2008", "2018", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "34.1", "34.1", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "140", "8", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.5", "96.2", "", "", "", "", "94.9"]} +{"pcdb_id": 15777, "brand_name": "Sime", "model_name": "Murelle HE", "model_qualifier": "35 System", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 34.1, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015777", "000213", "0", "2018/Mar/05 16:47", "Fonderie Sime S.p.A.", "Sime", "Murelle HE", "35 System", "", "2008", "2018", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "34.1", "34.1", "", "", "89.0", "80.0", "", "58.4", "", "2", "1", "", "102", "1", "2", "140", "8", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "91.5", "98.4", "", "", "", "", "97.1"]} +{"pcdb_id": 15778, "brand_name": "Sime", "model_name": "Murelle HE", "model_qualifier": "25/55 BF", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 80.7, "comparative_hot_water_efficiency_pct": 46.6, "output_kw_max": 23.9, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015778", "000213", "0", "2024/Jan/31 10:17", "Fonderie Sime S.p.A.", "Sime", "Murelle HE", "25/55 BF", "", "2008", "2018", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "23.9", "23.9", "", "", "88.0", "80.7", "", "46.6", "", "2", "", "", "106", "1", "2", "115", "8", "2", "1", "0", "48", "0", "20", "5", "60", "275", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "96.6", "", "", "", "", "95.0"]} +{"pcdb_id": 15779, "brand_name": "Sime", "model_name": "Murelle HE", "model_qualifier": "25/55 BF", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 81.7, "comparative_hot_water_efficiency_pct": 47.2, "output_kw_max": 23.9, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015779", "000213", "0", "2024/Jan/31 10:17", "Fonderie Sime S.p.A.", "Sime", "Murelle HE", "25/55 BF", "", "2008", "2018", "2", "2", "1", "2", "0", "", "", "2", "3", "2", "23.9", "23.9", "", "", "89.0", "81.7", "", "47.2", "", "2", "1", "", "106", "1", "2", "115", "8", "2", "1", "0", "48", "0", "20", "5", "60", "275", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.3", "98.7", "", "", "", "", "97.1"]} +{"pcdb_id": 15780, "brand_name": "Sime", "model_name": "Murelle HE", "model_qualifier": "30/55 BF", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 46.7, "output_kw_max": 28.9, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015780", "000213", "0", "2024/Jan/31 10:17", "Fonderie Sime S.p.A.", "Sime", "Murelle HE", "30/55 BF", "", "2008", "2018", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "28.9", "28.9", "", "", "88.1", "80.8", "", "46.7", "", "2", "", "", "106", "1", "2", "115", "8", "2", "1", "0", "48", "0", "20", "5", "60", "275", "0", "", "", "", "", "", "", "", "", "", "0", "0", "", "0005", "", "", "", "", "", "", "", "", "88.7", "96.8", "", "", "", "", "95.2"]} +{"pcdb_id": 15781, "brand_name": "Sime", "model_name": "Murelle HE", "model_qualifier": "30/55 BF", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 81.8, "comparative_hot_water_efficiency_pct": 47.2, "output_kw_max": 28.9, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 1, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015781", "000213", "0", "2024/Jan/31 10:17", "Fonderie Sime S.p.A.", "Sime", "Murelle HE", "30/55 BF", "", "2008", "2018", "2", "2", "1", "2", "0", "", "", "2", "3", "2", "28.9", "28.9", "", "", "89.1", "81.8", "", "47.2", "", "2", "1", "", "106", "1", "2", "115", "8", "1", "1", "0", "48", "0", "20", "5", "60", "275", "0", "", "", "", "", "", "", "", "", "", "0", "0", "", "0005", "", "", "", "", "", "", "", "", "90.6", "98.9", "", "", "", "", "97.3"]} +{"pcdb_id": 15782, "brand_name": "Heatline", "model_name": "Vizo Plus", "model_qualifier": "24", "winter_efficiency_pct": 87.8, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 55.7, "output_kw_max": 19.5, "final_year_of_manufacture": 2009, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015782", "000215", "0", "2011/Aug/31 10:38", "Turk Demir Dokum Fab AS", "Heatline", "Vizo Plus", "24", "GC No. 47-157-14", "2007", "2009", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "19.5", "19.5", "", "", "87.8", "79.2", "", "55.7", "", "2", "", "", "104", "1", "2", "175", "10", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "96.4", "", "", "", "", "94.8"]} +{"pcdb_id": 15783, "brand_name": "Firebird", "model_name": "Enviromax Combi C20", "model_qualifier": "", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 82.6, "comparative_hot_water_efficiency_pct": 50.6, "output_kw_max": 20.0, "final_year_of_manufacture": 2010, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015783", "000047", "0", "2024/Jan/31 10:17", "Firebird Boilers", "Firebird", "Enviromax Combi C20", "", "", "2007", "2010", "4", "1", "1", "2", "0", "", "", "2", "3", "1", "15", "20", "", "", "88.7", "82.6", "", "50.6", "", "2", "", "", "203", "1", "1", "38", "0", "2", "1", "0", "40", "0", "25", "1", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.7", "96.1", "", "", "", "", "95.3"]} +{"pcdb_id": 15784, "brand_name": "Firebird", "model_name": "Enviromax Combipac C20", "model_qualifier": "", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 82.6, "comparative_hot_water_efficiency_pct": 50.6, "output_kw_max": 20.0, "final_year_of_manufacture": 2010, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015784", "000047", "0", "2024/Jan/31 10:17", "Firebird Boilers", "Firebird", "Enviromax Combipac C20", "", "", "2007", "2010", "4", "1", "2", "2", "0", "", "", "2", "1", "1", "15", "20", "", "", "88.7", "82.6", "", "50.6", "", "2", "", "", "203", "1", "1", "38", "0", "2", "1", "0", "40", "0", "25", "1", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.7", "96.1", "", "", "", "", "95.3"]} +{"pcdb_id": 15785, "brand_name": "Firebird", "model_name": "Enviromax System C20", "model_qualifier": "", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 80.9, "comparative_hot_water_efficiency_pct": 59.1, "output_kw_max": 20.0, "final_year_of_manufacture": 2010, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015785", "000047", "0", "2012/Mar/27 10:12", "Firebird Boilers", "Firebird", "Enviromax System C20", "", "", "2007", "2010", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "15", "20", "", "", "88.7", "80.9", "", "59.1", "", "2", "", "", "201", "1", "1", "38", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.7", "96.1", "", "", "", "", "95.3"]} +{"pcdb_id": 15786, "brand_name": "Firebird", "model_name": "Enviromax Systempac C20", "model_qualifier": "", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 80.9, "comparative_hot_water_efficiency_pct": 59.1, "output_kw_max": 20.0, "final_year_of_manufacture": 2010, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015786", "000047", "0", "2012/Mar/27 10:12", "Firebird Boilers", "Firebird", "Enviromax Systempac C20", "", "", "2007", "2010", "4", "1", "2", "1", "0", "", "", "2", "1", "1", "15", "20", "", "", "88.7", "80.9", "", "59.1", "", "2", "", "", "201", "1", "1", "38", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.7", "96.1", "", "", "", "", "95.3"]} +{"pcdb_id": 15787, "brand_name": "Firebird", "model_name": "Enviromax Popular C20", "model_qualifier": "", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 80.9, "comparative_hot_water_efficiency_pct": 59.1, "output_kw_max": 20.0, "final_year_of_manufacture": 2010, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015787", "000047", "0", "2012/Mar/27 10:12", "Firebird Boilers", "Firebird", "Enviromax Popular C20", "", "", "2007", "2010", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "15", "20", "", "", "88.7", "80.9", "", "59.1", "", "2", "", "", "201", "1", "1", "38", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.7", "96.1", "", "", "", "", "95.3"]} +{"pcdb_id": 15788, "brand_name": "Firebird", "model_name": "Enviromax Heatpac C20", "model_qualifier": "", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 80.9, "comparative_hot_water_efficiency_pct": 59.1, "output_kw_max": 20.0, "final_year_of_manufacture": 2010, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015788", "000047", "0", "2012/Mar/27 10:12", "Firebird Boilers", "Firebird", "Enviromax Heatpac C20", "", "", "2007", "2010", "4", "1", "2", "1", "0", "", "", "2", "1", "1", "15", "20", "", "", "88.7", "80.9", "", "59.1", "", "2", "", "", "201", "1", "1", "38", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.7", "96.1", "", "", "", "", "95.3"]} +{"pcdb_id": 15789, "brand_name": "Firebird", "model_name": "Enviromax Kitchen C20", "model_qualifier": "", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 80.9, "comparative_hot_water_efficiency_pct": 59.1, "output_kw_max": 20.0, "final_year_of_manufacture": 2010, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015789", "000047", "0", "2012/Mar/27 10:12", "Firebird Boilers", "Firebird", "Enviromax Kitchen C20", "", "", "2007", "2010", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "15", "20", "", "", "88.7", "80.9", "", "59.1", "", "2", "", "", "201", "1", "2", "38", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "91.7", "96.1", "", "", "", "", "95.3"]} +{"pcdb_id": 15790, "brand_name": "Firebird", "model_name": "Enviromax Utility C20", "model_qualifier": "", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 80.9, "comparative_hot_water_efficiency_pct": 59.1, "output_kw_max": 20.0, "final_year_of_manufacture": 2010, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015790", "000047", "0", "2012/Mar/27 10:12", "Firebird Boilers", "Firebird", "Enviromax Utility C20", "", "", "2007", "2010", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "15", "20", "", "", "88.7", "80.9", "", "59.1", "", "2", "", "", "201", "1", "1", "38", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.7", "96.1", "", "", "", "", "95.3"]} +{"pcdb_id": 15791, "brand_name": "Firebird", "model_name": "Enviromax Combi C26", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 82.7, "comparative_hot_water_efficiency_pct": 50.7, "output_kw_max": 26.0, "final_year_of_manufacture": 2010, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015791", "000047", "0", "2024/Jan/31 10:17", "Firebird Boilers", "Firebird", "Enviromax Combi C26", "", "", "2007", "2010", "4", "1", "1", "2", "0", "", "", "2", "3", "1", "15", "26", "", "", "88.8", "82.7", "", "50.7", "", "2", "", "", "203", "1", "1", "38", "0", "2", "1", "0", "40", "0", "25", "1", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.6", "96.6", "", "", "", "", "95.7"]} +{"pcdb_id": 15792, "brand_name": "Firebird", "model_name": "Enviromax Combipac C26", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 82.7, "comparative_hot_water_efficiency_pct": 50.7, "output_kw_max": 26.0, "final_year_of_manufacture": 2010, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015792", "000047", "0", "2024/Jan/31 10:17", "Firebird Boilers", "Firebird", "Enviromax Combipac C26", "", "", "2007", "2010", "4", "1", "2", "2", "0", "", "", "2", "1", "1", "15", "26", "", "", "88.8", "82.7", "", "50.7", "", "2", "", "", "203", "1", "1", "38", "0", "2", "1", "0", "40", "0", "25", "1", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "0", "", "0003", "", "", "", "", "", "", "", "", "91.6", "96.6", "", "", "", "", "95.7"]} +{"pcdb_id": 15793, "brand_name": "Firebird", "model_name": "Enviromax System C26", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 59.2, "output_kw_max": 26.0, "final_year_of_manufacture": 2010, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015793", "000047", "0", "2012/Mar/27 10:12", "Firebird Boilers", "Firebird", "Enviromax System C26", "", "", "2007", "2010", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "15", "26", "", "", "88.8", "81.0", "", "59.2", "", "2", "", "", "201", "1", "1", "38", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.6", "96.6", "", "", "", "", "95.7"]} +{"pcdb_id": 15794, "brand_name": "Firebird", "model_name": "Enviromax Systempac C26", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 59.2, "output_kw_max": 26.0, "final_year_of_manufacture": 2010, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015794", "000047", "0", "2012/Mar/27 10:12", "Firebird Boilers", "Firebird", "Enviromax Systempac C26", "", "", "2007", "2010", "4", "1", "2", "1", "0", "", "", "2", "1", "1", "15", "26", "", "", "88.8", "81.0", "", "59.2", "", "2", "", "", "201", "1", "1", "38", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.6", "96.6", "", "", "", "", "95.7"]} +{"pcdb_id": 15795, "brand_name": "Firebird", "model_name": "Enviromax Popular C26", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 59.2, "output_kw_max": 26.0, "final_year_of_manufacture": 2010, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015795", "000047", "0", "2012/Mar/27 10:12", "Firebird Boilers", "Firebird", "Enviromax Popular C26", "", "", "2007", "2010", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "15", "26", "", "", "88.8", "81.0", "", "59.2", "", "2", "", "", "201", "1", "1", "38", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.6", "96.6", "", "", "", "", "95.7"]} +{"pcdb_id": 15796, "brand_name": "Firebird", "model_name": "Enviromax Heatpac C26", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 59.2, "output_kw_max": 26.0, "final_year_of_manufacture": 2010, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015796", "000047", "0", "2012/Mar/27 10:12", "Firebird Boilers", "Firebird", "Enviromax Heatpac C26", "", "", "2007", "2010", "4", "1", "2", "1", "0", "", "", "2", "1", "1", "15", "26", "", "", "88.8", "81.0", "", "59.2", "", "2", "", "", "201", "1", "1", "38", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.6", "96.6", "", "", "", "", "95.7"]} +{"pcdb_id": 15797, "brand_name": "Firebird", "model_name": "Enviromax Kitchen C26", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 59.2, "output_kw_max": 26.0, "final_year_of_manufacture": 2010, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015797", "000047", "0", "2012/Mar/27 10:12", "Firebird Boilers", "Firebird", "Enviromax Kitchen C26", "", "", "2007", "2010", "4", "1", "1", "1", "0", "", "", "2", "2", "1", "15", "26", "", "", "88.8", "81.0", "", "59.2", "", "2", "", "", "201", "1", "1", "38", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.6", "96.6", "", "", "", "", "95.7"]} +{"pcdb_id": 15798, "brand_name": "Firebird", "model_name": "Enviromax Utility C26", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 59.2, "output_kw_max": 26.0, "final_year_of_manufacture": 2010, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015798", "000047", "0", "2012/Mar/27 10:12", "Firebird Boilers", "Firebird", "Enviromax Utility C26", "", "", "2007", "2010", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "15", "26", "", "", "88.8", "81.0", "", "59.2", "", "2", "", "", "201", "1", "1", "8", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.6", "96.6", "", "", "", "", "95.7"]} +{"pcdb_id": 15799, "brand_name": "Firebird", "model_name": "Enviromax Combi C35", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 81.9, "comparative_hot_water_efficiency_pct": 50.1, "output_kw_max": 35.0, "final_year_of_manufacture": 2010, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015799", "000047", "0", "2024/Jan/31 10:17", "Firebird Boilers", "Firebird", "Enviromax Combi C35", "", "", "2007", "2010", "4", "1", "1", "2", "0", "", "", "2", "3", "1", "26", "35", "", "", "88.0", "81.9", "", "50.1", "", "2", "", "", "203", "1", "1", "38", "0", "2", "1", "0", "40", "0", "25", "1", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "0", "", "0003", "", "", "", "", "", "", "", "", "91.7", "94.4", "", "", "", "", "93.9"]} +{"pcdb_id": 15800, "brand_name": "Firebird", "model_name": "Enviromax Combipac C35", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 81.9, "comparative_hot_water_efficiency_pct": 50.1, "output_kw_max": 35.0, "final_year_of_manufacture": 2010, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015800", "000047", "0", "2024/Jan/31 10:17", "Firebird Boilers", "Firebird", "Enviromax Combipac C35", "", "", "2007", "2010", "4", "1", "2", "2", "0", "", "", "2", "1", "1", "26", "35", "", "", "88.0", "81.9", "", "50.1", "", "2", "", "", "203", "1", "1", "38", "0", "2", "1", "0", "40", "0", "25", "1", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "0", "", "0003", "", "", "", "", "", "", "", "", "91.7", "94.4", "", "", "", "", "93.9"]} +{"pcdb_id": 15801, "brand_name": "Firebird", "model_name": "Enviromax System C35", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 35.0, "final_year_of_manufacture": 2010, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015801", "000047", "0", "2012/Mar/27 10:12", "Firebird Boilers", "Firebird", "Enviromax System C35", "", "", "2007", "2010", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "26", "35", "", "", "88.0", "80.2", "", "58.6", "", "2", "", "", "201", "1", "1", "38", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.7", "94.4", "", "", "", "", "93.9"]} +{"pcdb_id": 15802, "brand_name": "Firebird", "model_name": "Enviromax Systempac C35", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 35.0, "final_year_of_manufacture": 2010, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015802", "000047", "0", "2012/Mar/27 10:12", "Firebird Boilers", "Firebird", "Enviromax Systempac C35", "", "", "2007", "2010", "4", "1", "2", "1", "0", "", "", "2", "1", "1", "26", "35", "", "", "88.0", "80.2", "", "58.6", "", "2", "", "", "201", "1", "1", "38", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.7", "94.4", "", "", "", "", "93.9"]} +{"pcdb_id": 15803, "brand_name": "Firebird", "model_name": "Enviromax Popular C35", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 35.0, "final_year_of_manufacture": 2010, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015803", "000047", "0", "2012/Mar/27 10:12", "Firebird Boilers", "Firebird", "Enviromax Popular C35", "", "", "2007", "2010", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "26", "35", "", "", "88.0", "80.2", "", "58.6", "", "2", "", "", "201", "1", "1", "38", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.7", "94.4", "", "", "", "", "93.9"]} +{"pcdb_id": 15804, "brand_name": "Firebird", "model_name": "Enviromax Heatpac C35", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 35.0, "final_year_of_manufacture": 2008, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015804", "000047", "0", "2012/Apr/17 15:10", "Firebird Boilers", "Firebird", "Enviromax Heatpac C35", "", "", "2007", "2008", "4", "1", "2", "1", "0", "", "", "2", "1", "1", "26", "35", "", "", "88.0", "80.2", "", "58.6", "", "2", "", "", "201", "1", "1", "38", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.7", "94.4", "", "", "", "", "93.9"]} +{"pcdb_id": 15805, "brand_name": "Firebird", "model_name": "Enviromax Kitchen C35", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 35.0, "final_year_of_manufacture": 2010, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015805", "000047", "0", "2012/Mar/27 10:12", "Firebird Boilers", "Firebird", "Enviromax Kitchen C35", "", "", "2007", "2010", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "26", "35", "", "", "88.0", "80.2", "", "58.6", "", "2", "", "", "201", "1", "1", "38", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.7", "94.4", "", "", "", "", "93.9"]} +{"pcdb_id": 15806, "brand_name": "Firebird", "model_name": "Enviromax Utility C35", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 35.0, "final_year_of_manufacture": 2010, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015806", "000047", "0", "2012/Mar/27 10:12", "Firebird Boilers", "Firebird", "Enviromax Utility C35", "", "", "2007", "2010", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "26", "35", "", "", "88.0", "80.2", "", "58.6", "", "2", "", "", "201", "1", "1", "38", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.7", "94.4", "", "", "", "", "93.9"]} +{"pcdb_id": 15807, "brand_name": "Firebird", "model_name": "Enviromax System C44", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 80.7, "comparative_hot_water_efficiency_pct": 58.9, "output_kw_max": 44.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015807", "000047", "0", "2012/Mar/27 10:12", "Firebird Boilers", "Firebird", "Enviromax System C44", "", "", "2007", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "35", "44", "", "", "88.5", "80.7", "", "58.9", "", "2", "", "", "201", "1", "1", "38", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.4", "95.8", "", "", "", "", "94.9"]} +{"pcdb_id": 15808, "brand_name": "Firebird", "model_name": "Enviromax Systempac C44", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 80.7, "comparative_hot_water_efficiency_pct": 58.9, "output_kw_max": 44.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015808", "000047", "0", "2012/Mar/27 10:12", "Firebird Boilers", "Firebird", "Enviromax Systempac C44", "", "", "2007", "current", "4", "1", "2", "1", "0", "", "", "2", "1", "1", "35", "44", "", "", "88.5", "80.7", "", "58.9", "", "2", "", "", "201", "1", "1", "38", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.4", "95.8", "", "", "", "", "94.9"]} +{"pcdb_id": 15809, "brand_name": "Firebird", "model_name": "Enviromax Popular C44", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 80.7, "comparative_hot_water_efficiency_pct": 58.9, "output_kw_max": 44.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015809", "000047", "0", "2012/Mar/27 10:12", "Firebird Boilers", "Firebird", "Enviromax Popular C44", "", "", "2007", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "35", "44", "", "", "88.5", "80.7", "", "58.9", "", "2", "", "", "201", "1", "1", "38", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.4", "95.8", "", "", "", "", "94.9"]} +{"pcdb_id": 15810, "brand_name": "Firebird", "model_name": "Enviromax Heatpac C44", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 80.7, "comparative_hot_water_efficiency_pct": 58.9, "output_kw_max": 44.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015810", "000047", "0", "2012/Mar/27 10:12", "Firebird Boilers", "Firebird", "Enviromax Heatpac C44", "", "", "2007", "current", "4", "1", "2", "1", "0", "", "", "2", "1", "1", "35", "44", "", "", "88.5", "80.7", "", "58.9", "", "2", "", "", "201", "1", "1", "338", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.4", "95.8", "", "", "", "", "94.9"]} +{"pcdb_id": 15811, "brand_name": "Firebird", "model_name": "Enviromax Kitchen C44", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 80.7, "comparative_hot_water_efficiency_pct": 58.9, "output_kw_max": 44.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015811", "000047", "0", "2012/Mar/27 10:12", "Firebird Boilers", "Firebird", "Enviromax Kitchen C44", "", "", "2007", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "35", "44", "", "", "88.5", "80.7", "", "58.9", "", "2", "", "", "201", "1", "1", "38", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.4", "95.8", "", "", "", "", "94.9"]} +{"pcdb_id": 15812, "brand_name": "Firebird", "model_name": "Enviromax Popular C58", "model_qualifier": "", "winter_efficiency_pct": 87.8, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 58.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015812", "000047", "0", "2012/Mar/27 10:12", "Firebird Boilers", "Firebird", "Enviromax Popular C58", "", "", "2007", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "44", "58", "", "", "87.8", "80.0", "", "58.5", "", "2", "", "", "201", "1", "1", "38", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.2", "94.3", "", "", "", "", "93.7"]} +{"pcdb_id": 15813, "brand_name": "Firebird", "model_name": "Enviromax Heatpac C58", "model_qualifier": "", "winter_efficiency_pct": 87.8, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 58.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015813", "000047", "0", "2012/Mar/27 10:12", "Firebird Boilers", "Firebird", "Enviromax Heatpac C58", "", "", "2007", "current", "4", "1", "2", "1", "0", "", "", "2", "1", "1", "44", "58", "", "", "87.8", "80.0", "", "58.5", "", "2", "", "", "201", "1", "1", "38", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.2", "94.3", "", "", "", "", "93.7"]} +{"pcdb_id": 15814, "brand_name": "Firebird", "model_name": "Enviromax Kitchen C58", "model_qualifier": "", "winter_efficiency_pct": 87.8, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 58.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015814", "000047", "0", "2012/Mar/27 10:12", "Firebird Boilers", "Firebird", "Enviromax Kitchen C58", "", "", "2007", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "44", "58", "", "", "87.8", "80.0", "", "58.5", "", "2", "", "", "201", "1", "1", "38", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.2", "94.3", "", "", "", "", "93.7"]} +{"pcdb_id": 15815, "brand_name": "Firebird", "model_name": "Enviromax Popular C73", "model_qualifier": "", "winter_efficiency_pct": 87.5, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": null, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015815", "000047", "0", "2012/Mar/27 10:12", "Firebird Boilers", "Firebird", "Enviromax Popular C73", "", "", "2007", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "58", ">70kW", "", "", "87.5", "79.7", "", "58.2", "", "2", "", "", "201", "1", "1", "38", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.0", "94.0", "", "", "", "", "93.2"]} +{"pcdb_id": 15816, "brand_name": "Firebird", "model_name": "Enviromax Heatpac C73", "model_qualifier": "", "winter_efficiency_pct": 87.5, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": null, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015816", "000047", "0", "2012/Mar/27 10:12", "Firebird Boilers", "Firebird", "Enviromax Heatpac C73", "", "", "2007", "current", "4", "1", "2", "1", "0", "", "", "2", "1", "1", "58", ">70kW", "", "", "87.5", "79.7", "", "58.2", "", "2", "", "", "201", "1", "1", "38", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.0", "94.0", "", "", "", "", "93.2"]} +{"pcdb_id": 15817, "brand_name": "Firebird", "model_name": "Enviromax Kitchen C73", "model_qualifier": "", "winter_efficiency_pct": 87.5, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": null, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015817", "000047", "0", "2012/Mar/27 10:12", "Firebird Boilers", "Firebird", "Enviromax Kitchen C73", "", "", "2007", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "58", ">70kW", "", "", "87.5", "79.7", "", "58.2", "", "2", "", "", "201", "1", "1", "38", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.0", "94.0", "", "", "", "", "93.2"]} +{"pcdb_id": 15818, "brand_name": "Sime", "model_name": "Ecomfort", "model_qualifier": "System Plus 25 HE", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 25.0, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015818", "000213", "0", "2018/Feb/26 16:48", "Fonderie Sime S.p.A.", "Sime", "Ecomfort", "System Plus 25 HE", "", "2008", "2018", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "25.0", "25.0", "", "", "88.9", "79.9", "", "58.4", "", "2", "1", "", "102", "1", "2", "150", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "91.0", "98.4", "", "", "", "", "97.0"]} +{"pcdb_id": 15819, "brand_name": "Sime", "model_name": "Ecomfort", "model_qualifier": "System Plus 25 HE", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 78.9, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 25.0, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015819", "000213", "0", "2018/Feb/26 16:47", "Fonderie Sime S.p.A.", "Sime", "Ecomfort", "System Plus 25 HE", "", "2008", "2018", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "25.0", "25.0", "", "", "87.9", "78.9", "", "57.7", "", "2", "", "", "102", "1", "2", "150", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.0", "96.2", "", "", "", "", "94.9"]} +{"pcdb_id": 15820, "brand_name": "Sime", "model_name": "Ecomfort", "model_qualifier": "Plus 25 HE", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 56.5, "output_kw_max": 25.0, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015820", "000213", "0", "2018/Feb/26 16:44", "Fonderie Sime S.p.A.", "Sime", "Ecomfort", "Plus 25 HE", "", "2008", "2018", "2", "2", "1", "2", "0", "", "", "2", "3", "2", "25", "25", "", "", "88.9", "80.3", "", "56.5", "", "2", "1", "", "104", "1", "2", "150", "10", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "91.0", "98.4", "", "", "", "", "97.0"]} +{"pcdb_id": 15821, "brand_name": "Sime", "model_name": "Ecomfort", "model_qualifier": "Plus 25 HE", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 55.8, "output_kw_max": 25.0, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015821", "000213", "0", "2018/Feb/26 16:43", "Fonderie Sime S.p.A.", "Sime", "Ecomfort", "Plus 25 HE", "", "2008", "2018", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "25.0", "25.0", "", "", "87.9", "79.3", "", "55.8", "", "2", "", "", "104", "1", "2", "150", "10", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.0", "96.2", "", "", "", "", "94.9"]} +{"pcdb_id": 15822, "brand_name": "Sime", "model_name": "Ecomfort", "model_qualifier": "Plus 30 HE", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.4, "comparative_hot_water_efficiency_pct": 56.5, "output_kw_max": 29.0, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015822", "000213", "0", "2018/Feb/26 16:45", "Fonderie Sime S.p.A.", "Sime", "Ecomfort", "Plus 30 HE", "", "2008", "2018", "2", "2", "1", "2", "0", "", "", "2", "3", "2", "29.0", "29.0", "", "", "89.0", "80.4", "", "56.5", "", "2", "1", "", "104", "1", "2", "160", "10", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.8", "98.5", "", "", "", "", "97.1"]} +{"pcdb_id": 15823, "brand_name": "Sime", "model_name": "Ecomfort", "model_qualifier": "Plus 30 HE", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 55.8, "output_kw_max": 29.0, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015823", "000213", "0", "2018/Feb/26 16:44", "Fonderie Sime S.p.A.", "Sime", "Ecomfort", "Plus 30 HE", "", "2008", "2018", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "29.0", "29.0", "", "", "88.0", "79.4", "", "55.8", "", "2", "", "", "104", "1", "2", "160", "10", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.8", "96.4", "", "", "", "", "95.0"]} +{"pcdb_id": 15824, "brand_name": "Buderus", "model_name": "Logamax Plus", "model_qualifier": "GB162-65kW", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 65.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015824", "000035", "0", "2012/Mar/27 10:12", "Bosch Thermotechnology", "Buderus", "Logamax Plus", "GB162-65kW", "", "2008", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "65", "65", "", "", "88.2", "79.2", "", "57.8", "", "2", "", "", "102", "1", "2", "99", "21", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "97.1", "", "", "", "", "95.5"]} +{"pcdb_id": 15826, "brand_name": "Radiant", "model_name": "RKR 18", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 56.1, "output_kw_max": 17.7, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015826", "000088", "0", "2008/Apr/18 11:36", "Radiant Bruciatori SpA", "Radiant", "RKR 18", "", "", "2008", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "17.7", "17.7", "", "", "88.3", "79.7", "", "56.1", "", "2", "", "", "104", "1", "2", "133", "5.4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.6", "97.4", "", "", "", "", "95.7"]} +{"pcdb_id": 15827, "brand_name": "Radiant", "model_name": "RKA 25/8", "model_qualifier": "", "winter_efficiency_pct": 87.7, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 55.6, "output_kw_max": 24.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015827", "000088", "0", "2008/Apr/18 11:36", "Radiant Bruciatori SpA", "Radiant", "RKA 25/8", "", "", "2008", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.60", "24.60", "", "", "87.7", "79.1", "", "55.6", "", "2", "", "", "104", "1", "2", "170", "5.4", "0", "", "", "13", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.7", "95.8", "", "", "", "", "94.4"]} +{"pcdb_id": 15828, "brand_name": "Radiant", "model_name": "RKA 18/100", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 81.6, "comparative_hot_water_efficiency_pct": 36.8, "output_kw_max": 17.7, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015828", "000088", "0", "2024/Jan/31 10:17", "Radiant Bruciatori SpA", "Radiant", "RKA 18/100", "", "", "2008", "current", "1", "1", "1", "2", "0", "", "", "2", "2", "2", "17.7", "17.7", "", "", "88.3", "81.6", "", "36.8", "", "2", "", "", "106", "1", "2", "150", "5.4", "2", "2", "0", "105", "0", "15", "2", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.6", "97.4", "", "", "", "", "95.7"]} +{"pcdb_id": 15829, "brand_name": "Radiant", "model_name": "RKA 18/8", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 56.1, "output_kw_max": 17.7, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015829", "000088", "0", "2008/Apr/18 11:36", "Radiant Bruciatori SpA", "Radiant", "RKA 18/8", "", "", "2008", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "17.7", "17.7", "", "", "88.3", "79.7", "", "56.1", "", "2", "", "", "104", "1", "2", "133", "5.4", "0", "", "", "13", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.6", "97.4", "", "", "", "", "95.7"]} +{"pcdb_id": 15830, "brand_name": "Radiant", "model_name": "RKA 18", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 81.1, "comparative_hot_water_efficiency_pct": 46.7, "output_kw_max": 17.7, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015830", "000088", "0", "2024/Jan/31 10:17", "Radiant Bruciatori SpA", "Radiant", "RKA 18", "", "", "2008", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "17.7", "17.7", "", "", "88.3", "81.1", "", "46.7", "", "2", "", "", "106", "1", "2", "133", "5.4", "2", "2", "0", "20", "0", "15", "2", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.6", "97.4", "", "", "", "", "95.7"]} +{"pcdb_id": 15831, "brand_name": "Radiant", "model_name": "RK 18/B", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 17.7, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015831", "000088", "0", "2012/Mar/27 10:12", "Radiant Bruciatori SpA", "Radiant", "RK 18/B", "", "", "2008", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "17.7", "17.7", "", "", "88.3", "79.3", "", "57.9", "", "2", "", "", "102", "1", "2", "130", "5.4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.6", "97.4", "", "", "", "", "95.7"]} +{"pcdb_id": 15832, "brand_name": "Radiant", "model_name": "RK 18", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 17.7, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015832", "000088", "0", "2012/Mar/27 10:12", "Radiant Bruciatori SpA", "Radiant", "RK 18", "", "", "2008", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "17.7", "17.7", "", "", "88.3", "79.3", "", "57.9", "", "2", "", "", "102", "1", "2", "130", "5.4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.6", "97.4", "", "", "", "", "95.7"]} +{"pcdb_id": 15833, "brand_name": "Glow-worm", "model_name": "Betacom 30c", "model_qualifier": "", "winter_efficiency_pct": 85.1, "summer_efficiency_pct": 76.5, "comparative_hot_water_efficiency_pct": 53.8, "output_kw_max": 27.6, "final_year_of_manufacture": 2013, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015833", "000207", "0", "2013/Aug/23 09:30", "Vaillant Group UK", "Glow-worm", "Betacom 30c", "", "47-019-09", "2008", "2013", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "27.6", "27.6", "", "", "85.1", "76.5", "", "53.8", "", "2", "", "", "104", "1", "2", "164", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.2", "89.7", "", "", "", "", "89.3"]} +{"pcdb_id": 15834, "brand_name": "Glow-worm", "model_name": "Betacom 24c", "model_qualifier": "", "winter_efficiency_pct": 85.0, "summer_efficiency_pct": 76.4, "comparative_hot_water_efficiency_pct": 53.7, "output_kw_max": 24.7, "final_year_of_manufacture": 2013, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015834", "000207", "0", "2013/Aug/23 09:29", "Vaillant Group UK", "Glow-worm", "Betacom 24c", "", "47-019-08", "2008", "2013", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.7", "24.7", "", "", "85.0", "76.4", "", "53.7", "", "2", "", "", "104", "1", "2", "164", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "86.5", "89.7", "", "", "", "", "89.1"]} +{"pcdb_id": 15835, "brand_name": "Johnson & Starley", "model_name": "RenoXtra", "model_qualifier": "30 CP", "winter_efficiency_pct": 89.8, "summer_efficiency_pct": 81.2, "comparative_hot_water_efficiency_pct": 57.1, "output_kw_max": 25.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015835", "000239", "0", "2008/Sep/29 16:19", "Johnson & Starley", "Johnson & Starley", "RenoXtra", "30 CP", "", "2008", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "25", "25", "", "", "89.8", "81.2", "", "57.1", "", "2", "1", "", "104", "1", "2", "145", "0", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.6", "101.0", "", "", "", "", "98.9"]} +{"pcdb_id": 15836, "brand_name": "Johnson & Starley", "model_name": "RenoXtra", "model_qualifier": "37 CP", "winter_efficiency_pct": 90.1, "summer_efficiency_pct": 81.5, "comparative_hot_water_efficiency_pct": 57.3, "output_kw_max": 30.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015836", "000239", "0", "2008/Sep/29 16:19", "Johnson & Starley", "Johnson & Starley", "RenoXtra", "37 CP", "", "2008", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "30", "30", "", "", "90.1", "81.5", "", "57.3", "", "2", "1", "", "104", "1", "2", "145", "0", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.8", "101.7", "", "", "", "", "99.4"]} +{"pcdb_id": 15837, "brand_name": "Johnson & Starley", "model_name": "RenoXtra", "model_qualifier": "37C", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.4, "comparative_hot_water_efficiency_pct": 56.6, "output_kw_max": 30.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015837", "000239", "0", "2010/Sep/29 12:36", "Johnson & Starley", "Johnson & Starley", "RenoXtra", "37C", "", "2008", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "30", "30", "", "", "89.0", "80.4", "", "56.6", "", "2", "", "", "104", "1", "2", "145", "0", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "99.5", "", "", "", "", "97.3"]} +{"pcdb_id": 15838, "brand_name": "Johnson & Starley", "model_name": "RenoXtra", "model_qualifier": "30C", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 56.4, "output_kw_max": 25.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015838", "000239", "0", "2010/Sep/29 12:36", "Johnson & Starley", "Johnson & Starley", "RenoXtra", "30C", "", "2008", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "25", "25", "", "", "88.8", "80.2", "", "56.4", "", "2", "", "", "104", "1", "2", "145", "0", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.7", "98.8", "", "", "", "", "96.7"]} +{"pcdb_id": 15840, "brand_name": "Grant", "model_name": "Euroflame Condensing", "model_qualifier": "Module 90-120", "winter_efficiency_pct": 87.5, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 34.7, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015840", "000048", "0", "2012/Mar/27 10:12", "Grant Engineering", "Grant", "Euroflame Condensing", "Module 90-120", "", "2008", "current", "4", "1", "2", "1", "0", "", "", "2", "3", "2", "25.6", "34.7", "", "", "87.5", "79.7", "", "58.2", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.3", "93.8", "", "", "", "", "93.1"]} +{"pcdb_id": 15841, "brand_name": "Heatline", "model_name": "Capriz", "model_qualifier": "25", "winter_efficiency_pct": 85.0, "summer_efficiency_pct": 76.4, "comparative_hot_water_efficiency_pct": 53.7, "output_kw_max": 24.7, "final_year_of_manufacture": 2009, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015841", "000215", "0", "2011/Aug/31 10:42", "Turk Demir Dokum Fab AS", "Heatline", "Capriz", "25", "GC No 47-157-12", "2008", "2009", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.7", "24.7", "", "", "85.0", "76.4", "", "53.7", "", "2", "", "", "104", "1", "2", "175", "10", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "86.5", "89.7", "", "", "", "", "89.1"]} +{"pcdb_id": 15842, "brand_name": "Heatline", "model_name": "Capriz", "model_qualifier": "28", "winter_efficiency_pct": 85.1, "summer_efficiency_pct": 76.5, "comparative_hot_water_efficiency_pct": 53.8, "output_kw_max": 27.6, "final_year_of_manufacture": 2009, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015842", "000215", "0", "2011/Aug/31 10:42", "Turk Demir Dokum Fab AS", "Heatline", "Capriz", "28", "GC No 47-157-13", "2008", "2009", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "27.6", "27.6", "", "", "85.1", "76.5", "", "53.8", "", "2", "", "", "104", "1", "2", "175", "10", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.2", "89.7", "", "", "", "", "89.3"]} +{"pcdb_id": 15843, "brand_name": "Heatline", "model_name": "Capriz", "model_qualifier": "25S", "winter_efficiency_pct": 85.0, "summer_efficiency_pct": 76.0, "comparative_hot_water_efficiency_pct": 55.5, "output_kw_max": 24.7, "final_year_of_manufacture": 2009, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015843", "000215", "0", "2012/Mar/27 10:12", "Turk Demir Dokum Fab AS", "Heatline", "Capriz", "25S", "GC No 41-157-10", "2008", "2009", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24.7", "24.7", "", "", "85.0", "76.0", "", "55.5", "", "2", "", "", "102", "1", "2", "175", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "86.5", "89.7", "", "", "", "", "89.1"]} +{"pcdb_id": 15844, "brand_name": "Heatline", "model_name": "Capriz", "model_qualifier": "28S", "winter_efficiency_pct": 85.1, "summer_efficiency_pct": 76.1, "comparative_hot_water_efficiency_pct": 55.6, "output_kw_max": 27.6, "final_year_of_manufacture": 2009, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015844", "000215", "0", "2012/Mar/27 10:12", "Turk Demir Dokum Fab AS", "Heatline", "Capriz", "28S", "GC No 41-157-11", "2008", "2009", "1", "2", "1", "1", "0", "", "", "2", "1", "2", "27.6", "27.6", "", "", "85.1", "76.1", "", "55.6", "", "2", "", "", "102", "1", "2", "175", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.2", "89.7", "", "", "", "", "89.3"]} +{"pcdb_id": 15845, "brand_name": "Hyrdoline", "model_name": "B24", "model_qualifier": "", "winter_efficiency_pct": 85.0, "summer_efficiency_pct": 76.4, "comparative_hot_water_efficiency_pct": 53.7, "output_kw_max": 24.7, "final_year_of_manufacture": 2008, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015845", "000215", "0", "2011/Aug/31 10:42", "Turk Demir Dokum Fab AS", "Hyrdoline", "B24", "", "GC No 47-157-18", "2008", "2008", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.7", "24.7", "", "", "85.0", "76.4", "", "53.7", "", "2", "", "", "104", "1", "2", "175", "10", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "86.5", "89.7", "", "", "", "", "89.1"]} +{"pcdb_id": 15846, "brand_name": "Heatline", "model_name": "Sargon", "model_qualifier": "24", "winter_efficiency_pct": 87.8, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 55.7, "output_kw_max": 19.5, "final_year_of_manufacture": 2009, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015846", "000215", "0", "2011/Aug/31 10:38", "Turk Demir Dokum Fab AS", "Heatline", "Sargon", "24", "GC No 47-157-15", "2008", "2009", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "19.5", "19.5", "", "", "87.8", "79.2", "", "55.7", "", "2", "", "", "104", "1", "2", "175", "10", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "96.4", "", "", "", "", "94.8"]} +{"pcdb_id": 15849, "brand_name": "Heatline", "model_name": "Sargon", "model_qualifier": "30", "winter_efficiency_pct": 87.8, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 55.7, "output_kw_max": 24.4, "final_year_of_manufacture": 2009, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015849", "000215", "0", "2011/Aug/31 10:38", "Turk Demir Dokum Fab AS", "Heatline", "Sargon", "30", "GC No 47-157-16", "2008", "2009", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.4", "24.4", "", "", "87.8", "79.2", "", "55.7", "", "2", "", "", "104", "1", "2", "175", "10", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "96.4", "", "", "", "", "94.8"]} +{"pcdb_id": 15850, "brand_name": "Heatline", "model_name": "Sargon", "model_qualifier": "35", "winter_efficiency_pct": 87.8, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 55.7, "output_kw_max": 29.8, "final_year_of_manufacture": 2009, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015850", "000215", "0", "2011/Aug/31 10:40", "Turk Demir Dokum Fab AS", "Heatline", "Sargon", "35", "GC no 47-157-17", "2008", "2009", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "29.8", "29.8", "", "", "87.8", "79.2", "", "55.7", "", "2", "", "", "104", "1", "2", "175", "10", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "96.3", "", "", "", "", "94.7"]} +{"pcdb_id": 15851, "brand_name": "Heatline", "model_name": "Sargon", "model_qualifier": "20S", "winter_efficiency_pct": 87.8, "summer_efficiency_pct": 78.8, "comparative_hot_water_efficiency_pct": 57.6, "output_kw_max": 19.5, "final_year_of_manufacture": 2009, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015851", "000215", "0", "2012/Mar/27 10:12", "Turk Demir Dokum Fab AS", "Heatline", "Sargon", "20S", "GC No 41-157-12", "2008", "2009", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "19.5", "19.5", "", "", "87.8", "78.8", "", "57.6", "", "2", "", "", "102", "1", "2", "175", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "96.4", "", "", "", "", "94.8"]} +{"pcdb_id": 15852, "brand_name": "Heatline", "model_name": "Sargon", "model_qualifier": "24S", "winter_efficiency_pct": 87.8, "summer_efficiency_pct": 78.8, "comparative_hot_water_efficiency_pct": 57.6, "output_kw_max": 24.4, "final_year_of_manufacture": 2009, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015852", "000215", "0", "2012/Mar/27 10:12", "Turk Demir Dokum Fab AS", "Heatline", "Sargon", "24S", "GC No 41-157-13", "2008", "2009", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24.4", "24.4", "", "", "87.8", "78.8", "", "57.6", "", "2", "", "", "102", "1", "2", "175", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "96.4", "", "", "", "", "94.8"]} +{"pcdb_id": 15853, "brand_name": "Heatline", "model_name": "Sargon", "model_qualifier": "30S", "winter_efficiency_pct": 87.8, "summer_efficiency_pct": 78.8, "comparative_hot_water_efficiency_pct": 57.6, "output_kw_max": 29.8, "final_year_of_manufacture": 2009, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015853", "000215", "0", "2012/Mar/27 10:12", "Turk Demir Dokum Fab AS", "Heatline", "Sargon", "30S", "GC No 41-157-13", "2008", "2009", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "29.8", "29.8", "", "", "87.8", "78.8", "", "57.6", "", "2", "", "", "102", "1", "2", "175", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "96.3", "", "", "", "", "94.7"]} +{"pcdb_id": 15854, "brand_name": "Grant", "model_name": "Euroflame Condensing", "model_qualifier": "Indoor 50-70", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 20.7, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015854", "000048", "0", "2012/Mar/27 10:12", "Grant Engineering", "Grant", "Euroflame Condensing", "Indoor 50-70", "", "2008", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "15", "20.7", "", "", "88.0", "80.2", "", "58.6", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.5", "94.4", "", "", "", "", "93.9"]} +{"pcdb_id": 15855, "brand_name": "Grant", "model_name": "Euroflame Condensing", "model_qualifier": "Indoor 70-90", "winter_efficiency_pct": 87.8, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 25.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015855", "000048", "0", "2012/Mar/27 10:12", "Grant Engineering", "Grant", "Euroflame Condensing", "Indoor 70-90", "", "2008", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "20.7", "25.6", "", "", "87.8", "80.0", "", "58.4", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.4", "94.4", "", "", "", "", "93.6"]} +{"pcdb_id": 15856, "brand_name": "Grant", "model_name": "Euroflame Condensing", "model_qualifier": "Indoor 90-120", "winter_efficiency_pct": 87.5, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 34.7, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015856", "000048", "0", "2012/Mar/27 10:12", "Grant Engineering", "Grant", "Euroflame Condensing", "Indoor 90-120", "", "2008", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "25.6", "34.7", "", "", "87.5", "79.7", "", "58.2", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.3", "93.8", "", "", "", "", "93.1"]} +{"pcdb_id": 15857, "brand_name": "Grant", "model_name": "Euroflame Condensing", "model_qualifier": "Boilerhouse 50-70", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 20.7, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015857", "000048", "0", "2012/Mar/27 10:12", "Grant Engineering", "Grant", "Euroflame Condensing", "Boilerhouse 50-70", "", "2008", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "15", "20.7", "", "", "88.0", "80.2", "", "58.6", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.5", "94.4", "", "", "", "", "93.9"]} +{"pcdb_id": 15858, "brand_name": "Grant", "model_name": "Euroflame Condensing", "model_qualifier": "Boilerhouse 70-90", "winter_efficiency_pct": 87.8, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 25.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015858", "000048", "0", "2012/Mar/27 10:12", "Grant Engineering", "Grant", "Euroflame Condensing", "Boilerhouse 70-90", "", "2008", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "20.7", "25.6", "", "", "87.8", "80.0", "", "58.4", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.4", "94.4", "", "", "", "", "93.6"]} +{"pcdb_id": 15859, "brand_name": "Grant", "model_name": "Euroflame Condensing", "model_qualifier": "Boilerhouse 90-120", "winter_efficiency_pct": 87.5, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 34.7, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015859", "000048", "0", "2012/Mar/27 10:12", "Grant Engineering", "Grant", "Euroflame Condensing", "Boilerhouse 90-120", "", "2008", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "25.6", "34.7", "", "", "87.5", "79.7", "", "58.2", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.3", "93.8", "", "", "", "", "93.1"]} +{"pcdb_id": 15860, "brand_name": "Grant", "model_name": "Euroflame Condensing", "model_qualifier": "Module 50-70", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 20.7, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015860", "000048", "0", "2012/Mar/27 10:12", "Grant Engineering", "Grant", "Euroflame Condensing", "Module 50-70", "", "2008", "current", "4", "1", "2", "1", "0", "", "", "2", "3", "2", "15", "20.7", "", "", "88.0", "80.2", "", "58.6", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.5", "94.4", "", "", "", "", "93.9"]} +{"pcdb_id": 15861, "brand_name": "Grant", "model_name": "Euroflame Condensing", "model_qualifier": "Module 70-90", "winter_efficiency_pct": 87.8, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 25.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015861", "000048", "0", "2012/Mar/27 10:12", "Grant Engineering", "Grant", "Euroflame Condensing", "Module 70-90", "", "2008", "current", "4", "1", "2", "1", "0", "", "", "2", "3", "2", "20.7", "25.6", "", "", "87.8", "80.0", "", "58.4", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.4", "94.4", "", "", "", "", "93.6"]} +{"pcdb_id": 15862, "brand_name": "Viessmann", "model_name": "Vitodens 100-w wb1a", "model_qualifier": "13kW", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 11.8, "final_year_of_manufacture": 2007, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015862", "000033", "0", "2012/Mar/27 10:12", "Viessmann", "Viessmann", "Vitodens 100-w wb1a", "13kW", "", "2007", "2007", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "11.8", "11.8", "", "", "88.7", "79.7", "", "58.2", "", "2", "", "", "102", "1", "2", "55", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.3", "98.1", "", "", "", "", "96.4"]} +{"pcdb_id": 15863, "brand_name": "Viessmann", "model_name": "Vitodens 200-W WB2B", "model_qualifier": "19kW System boiler", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 17.5, "final_year_of_manufacture": 2012, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015863", "000033", "0", "2012/Mar/27 10:12", "Viessmann", "Viessmann", "Vitodens 200-W WB2B", "19kW System boiler", "", "2007", "2012", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "17.5", "17.5", "", "", "88.3", "79.3", "", "58.0", "", "2", "", "", "102", "1", "2", "85", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "97.7", "", "", "", "", "95.8"]} +{"pcdb_id": 15864, "brand_name": "Viessmann", "model_name": "Vitodens 200-W WB2B", "model_qualifier": "19kW System boiler", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 80.4, "comparative_hot_water_efficiency_pct": 58.7, "output_kw_max": 17.5, "final_year_of_manufacture": 2012, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015864", "000033", "0", "2012/Mar/27 10:12", "Viessmann", "Viessmann", "Vitodens 200-W WB2B", "19kW System boiler", "", "2007", "2012", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "17.5", "17.5", "", "", "89.4", "80.4", "", "58.7", "", "2", "1", "", "102", "1", "2", "85", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.0", "99.8", "", "", "", "", "98.0"]} +{"pcdb_id": 15865, "brand_name": "Viessmann", "model_name": "Vitodens 200-W WB2B", "model_qualifier": "26 kW System boiler", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 24.1, "final_year_of_manufacture": 2012, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015865", "000033", "0", "2012/Aug/28 09:47", "Viessmann", "Viessmann", "Vitodens 200-W WB2B", "26 kW System boiler", "", "2007", "2012", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24.1", "24.1", "", "", "88.6", "79.6", "", "58.1", "", "2", "", "", "102", "1", "2", "95", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.9", "97.9", "", "", "", "", "96.2"]} +{"pcdb_id": 15866, "brand_name": "Viessmann", "model_name": "Vitodens 200-W WB2B", "model_qualifier": "26kW System boiler", "winter_efficiency_pct": 89.6, "summer_efficiency_pct": 80.6, "comparative_hot_water_efficiency_pct": 58.9, "output_kw_max": 24.1, "final_year_of_manufacture": 2012, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015866", "000033", "0", "2012/Mar/27 10:12", "Viessmann", "Viessmann", "Vitodens 200-W WB2B", "26kW System boiler", "", "2007", "2012", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "24.1", "24.1", "", "", "89.6", "80.6", "", "58.9", "", "2", "1", "", "102", "1", "2", "95", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.9", "100.1", "", "", "", "", "98.4"]} +{"pcdb_id": 15867, "brand_name": "Viessmann", "model_name": "Vitodens 200-W WB2B", "model_qualifier": "30kW Combi boiler", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 56.2, "output_kw_max": 27.8, "final_year_of_manufacture": 2012, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015867", "000033", "0", "2012/Jun/28 11:05", "Viessmann", "Viessmann", "Vitodens 200-W WB2B", "30kW Combi boiler", "", "2007", "2012", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "27.8", "27.8", "", "", "88.6", "80.0", "", "56.2", "", "2", "", "", "104", "1", "2", "115", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.2", "97.8", "", "", "", "", "96.1"]} +{"pcdb_id": 15868, "brand_name": "Viessmann", "model_name": "Vitodens 200-W WB2B", "model_qualifier": "30kW Combi boiler", "winter_efficiency_pct": 89.6, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 57.0, "output_kw_max": 27.8, "final_year_of_manufacture": 2012, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015868", "000033", "0", "2008/Sep/29 16:10", "Viessmann", "Viessmann", "Vitodens 200-W WB2B", "30kW Combi boiler", "", "2007", "2012", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "27.8", "27.8", "", "", "89.6", "81.0", "", "57.0", "", "2", "1", "", "104", "1", "2", "115", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "91.2", "99.9", "", "", "", "", "98.3"]} +{"pcdb_id": 15869, "brand_name": "Viessmann", "model_name": "Vitodens 200-W WB2B", "model_qualifier": "35kW Combi boiler", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 56.2, "output_kw_max": 32.2, "final_year_of_manufacture": 2012, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015869", "000033", "0", "2012/Jun/28 11:05", "Viessmann", "Viessmann", "Vitodens 200-W WB2B", "35kW Combi boiler", "", "2007", "2012", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "32.2", "32.2", "", "", "88.5", "79.9", "", "56.2", "", "2", "", "", "104", "1", "2", "115", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.7", "97.8", "", "", "", "", "96.0"]} +{"pcdb_id": 15870, "brand_name": "Viessmann", "model_name": "Vitodens 200-W WB2B", "model_qualifier": "35kW Combi boiler", "winter_efficiency_pct": 90.4, "summer_efficiency_pct": 81.8, "comparative_hot_water_efficiency_pct": 57.5, "output_kw_max": 32.2, "final_year_of_manufacture": 2012, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015870", "000033", "0", "2010/Mar/11 12:40", "Viessmann", "Viessmann", "Vitodens 200-W WB2B", "35kW Combi boiler", "", "2007", "2012", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "32.2", "32.2", "", "", "90.4", "81.8", "", "57.5", "", "2", "0", "", "104", "1", "2", "115", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.7", "99.6", "", "", "", "", "97.9"]} +{"pcdb_id": 15871, "brand_name": "Viessmann", "model_name": "Vitodens 343F", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 81.1, "comparative_hot_water_efficiency_pct": 41.7, "output_kw_max": 11.8, "final_year_of_manufacture": 2012, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015871", "000033", "0", "2024/Jan/31 10:17", "Viessmann", "Viessmann", "Vitodens 343F", "", "", "2008", "2012", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "11.8", "11.8", "", "", "88.4", "81.1", "", "41.7", "", "2", "", "", "106", "1", "2", "126", "", "2", "1", "0", "250", "0", "50", "5", "60", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "97.8", "", "", "", "", "95.9"]} +{"pcdb_id": 15872, "brand_name": "Viessmann", "model_name": "Vitodens 343F", "model_qualifier": "", "winter_efficiency_pct": 90.4, "summer_efficiency_pct": 83.1, "comparative_hot_water_efficiency_pct": 42.7, "output_kw_max": 11.8, "final_year_of_manufacture": 2012, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015872", "000033", "0", "2024/Jan/31 10:17", "Viessmann", "Viessmann", "Vitodens 343F", "", "", "2008", "2012", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "11.8", "11.8", "", "", "90.4", "83.1", "", "42.7", "", "2", "0", "", "106", "1", "2", "126", "", "2", "1", "0", "250", "0", "50", "5", "60", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.7", "100.0", "", "", "", "", "98.1"]} +{"pcdb_id": 15873, "brand_name": "Potterton", "model_name": "Promax Combi", "model_qualifier": "24 HE Plus LPG", "winter_efficiency_pct": 90.4, "summer_efficiency_pct": 81.8, "comparative_hot_water_efficiency_pct": 57.5, "output_kw_max": 20.0, "final_year_of_manufacture": 2012, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015873", "000005", "0", "2013/May/07 10:36", "Baxi Heating UK", "Potterton", "Promax Combi", "24 HE Plus LPG", "GC No. 47-393-24", "2008", "2012", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "20.0", "20.0", "", "", "90.4", "81.8", "", "57.5", "", "2", "0", "", "104", "1", "2", "155", "5", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "92.0", "99.0", "", "", "", "", "97.7"]} +{"pcdb_id": 15874, "brand_name": "Potterton", "model_name": "Promax System", "model_qualifier": "24 HE Plus LPG", "winter_efficiency_pct": 90.4, "summer_efficiency_pct": 81.4, "comparative_hot_water_efficiency_pct": 59.4, "output_kw_max": 24.0, "final_year_of_manufacture": 2012, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015874", "000005", "0", "2013/May/07 10:36", "Baxi Heating UK", "Potterton", "Promax System", "24 HE Plus LPG", "GC No. 41-592-11", "2008", "2012", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "24.0", "24.0", "", "", "90.4", "81.4", "", "59.4", "", "2", "0", "", "102", "1", "2", "150", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "91.9", "99.0", "", "", "", "", "97.7"]} +{"pcdb_id": 15875, "brand_name": "Baxi", "model_name": "Duo-tec Combi", "model_qualifier": "28 HE LPG", "winter_efficiency_pct": 90.4, "summer_efficiency_pct": 81.8, "comparative_hot_water_efficiency_pct": 57.5, "output_kw_max": 24.0, "final_year_of_manufacture": 2012, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015875", "000005", "0", "2013/May/07 10:36", "Baxi Heating UK", "Baxi", "Duo-tec Combi", "28 HE LPG", "GC No. 47-075-39", "2008", "2012", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24.0", "24.0", "", "", "90.4", "81.8", "", "57.5", "", "2", "0", "", "104", "1", "2", "155", "5", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "92.0", "99.0", "", "", "", "", "97.7"]} +{"pcdb_id": 15877, "brand_name": "Rinnai UK", "model_name": "E32S", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 28.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015877", "000253", "0", "2012/Mar/27 10:12", "ATAG Verwarming Nederland BV", "Rinnai UK", "E32S", "", "", "2008", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "28.2", "28.2", "", "", "88.8", "79.8", "", "58.3", "", "2", "", "", "102", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "98.8", "", "", "", "", "96.8"]} +{"pcdb_id": 15879, "brand_name": "Vokera", "model_name": "Mynute", "model_qualifier": "15VHE", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 14.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015879", "000011", "0", "2012/Mar/27 10:12", "Vokera", "Vokera", "Mynute", "15VHE", "41-094-68", "2007", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "14.60", "14.60", "", "", "88.6", "79.6", "", "58.2", "", "2", "", "", "102", "1", "2", "150", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.7", "98.5", "", "", "", "", "96.4"]} +{"pcdb_id": 15881, "brand_name": "Vokera", "model_name": "Mynute", "model_qualifier": "15VHE", "winter_efficiency_pct": 90.1, "summer_efficiency_pct": 81.1, "comparative_hot_water_efficiency_pct": 59.3, "output_kw_max": 14.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015881", "000011", "0", "2012/Mar/27 10:12", "Vokera", "Vokera", "Mynute", "15VHE", "41-094-69", "2007", "current", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "14.60", "14.60", "", "", "90.1", "81.1", "", "59.3", "", "2", "0", "", "102", "1", "2", "150", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.3", "99.5", "", "", "", "", "97.5"]} +{"pcdb_id": 15883, "brand_name": "Ariston", "model_name": "E-Combi 24", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 56.0, "output_kw_max": 21.6, "final_year_of_manufacture": 2013, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015883", "000080", "0", "2014/Apr/15 14:58", "Merloni TermoSanitari SpA", "Ariston", "E-Combi 24", "", "47-116-62", "2008", "2013", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "21.6", "21.6", "", "", "88.3", "79.7", "", "56.0", "", "2", "", "", "104", "1", "2", "120", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "97.3", "", "", "", "", "95.6"]} +{"pcdb_id": 15884, "brand_name": "Ariston", "model_name": "E-Combi 30", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 56.1, "output_kw_max": 27.4, "final_year_of_manufacture": 2013, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015884", "000080", "0", "2013/Nov/04 15:30", "Merloni TermoSanitari SpA", "Ariston", "E-Combi 30", "", "47-116-63", "2008", "2013", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "27.4", "27.4", "", "", "88.3", "79.7", "", "56.1", "", "2", "", "", "104", "1", "2", "120", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "97.5", "", "", "", "", "95.7"]} +{"pcdb_id": 15885, "brand_name": "Ariston", "model_name": "E-Combi 38", "model_qualifier": "", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 55.8, "output_kw_max": 30.3, "final_year_of_manufacture": 2013, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015885", "000080", "0", "2014/Apr/15 14:59", "Merloni TermoSanitari SpA", "Ariston", "E-Combi 38", "", "47-116-64", "2008", "2013", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "30.3", "30.3", "", "", "87.9", "79.3", "", "55.8", "", "2", "", "", "104", "1", "2", "120", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "96.6", "", "", "", "", "94.9"]} +{"pcdb_id": 15886, "brand_name": "Viessmann", "model_name": "Vitodens 200-W WB2B", "model_qualifier": "30 kW System Boiler", "winter_efficiency_pct": 89.6, "summer_efficiency_pct": 80.6, "comparative_hot_water_efficiency_pct": 58.9, "output_kw_max": 27.8, "final_year_of_manufacture": 2012, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015886", "000033", "0", "2012/Mar/27 10:12", "Viessmann", "Viessmann", "Vitodens 200-W WB2B", "30 kW System Boiler", "", "2007", "2012", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "27.8", "27.8", "", "", "89.6", "80.6", "", "58.9", "", "2", "1", "", "102", "1", "2", "115", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "91.2", "99.9", "", "", "", "", "98.3"]} +{"pcdb_id": 15887, "brand_name": "Viessmann", "model_name": "Vitodens 200-W WB2B", "model_qualifier": "35kW System Boiler", "winter_efficiency_pct": 89.5, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 58.8, "output_kw_max": 32.2, "final_year_of_manufacture": 2012, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015887", "000033", "0", "2012/Mar/27 10:12", "Viessmann", "Viessmann", "Vitodens 200-W WB2B", "35kW System Boiler", "", "2007", "2012", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "32.2", "32.2", "", "", "89.5", "80.5", "", "58.8", "", "2", "1", "", "102", "1", "2", "115", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.6", "99.9", "", "", "", "", "98.2"]} +{"pcdb_id": 15888, "brand_name": "Viessmann", "model_name": "Vitodens 200-W WB2B", "model_qualifier": "26 kW Combi Boiler", "winter_efficiency_pct": 89.6, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 57.0, "output_kw_max": 24.1, "final_year_of_manufacture": 2012, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015888", "000033", "0", "2010/Jun/22 10:32", "Viessmann", "Viessmann", "Vitodens 200-W WB2B", "26 kW Combi Boiler", "", "2007", "2012", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24.1", "24.1", "", "", "89.6", "81.0", "", "57.0", "", "2", "1", "", "104", "1", "2", "95", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.9", "100.1", "", "", "", "", "98.4"]} +{"pcdb_id": 15889, "brand_name": "Viessmann", "model_name": "Vitodens 200-W WB2B", "model_qualifier": "30kW System Boiler", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 27.8, "final_year_of_manufacture": 2012, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015889", "000033", "0", "2012/Mar/27 10:12", "Viessmann", "Viessmann", "Vitodens 200-W WB2B", "30kW System Boiler", "", "2007", "2012", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "27.8", "27.8", "", "", "88.6", "79.6", "", "58.1", "", "2", "", "", "102", "1", "2", "115", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.2", "97.8", "", "", "", "", "96.1"]} +{"pcdb_id": 15890, "brand_name": "Viessmann", "model_name": "Vitodens 200-W WB2B", "model_qualifier": "35kW System Boiler", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 32.2, "final_year_of_manufacture": 2012, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015890", "000033", "0", "2012/Mar/27 10:12", "Viessmann", "Viessmann", "Vitodens 200-W WB2B", "35kW System Boiler", "", "2007", "2012", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "32.2", "32.2", "", "", "88.5", "79.5", "", "58.1", "", "2", "", "", "102", "1", "2", "115", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.7", "97.8", "", "", "", "", "96.0"]} +{"pcdb_id": 15891, "brand_name": "Viessmann", "model_name": "Vitodens 200-W WB2B", "model_qualifier": "26kW Combi Boiler", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 56.3, "output_kw_max": 24.1, "final_year_of_manufacture": 2012, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015891", "000033", "0", "2012/Aug/28 09:54", "Viessmann", "Viessmann", "Vitodens 200-W WB2B", "26kW Combi Boiler", "", "2007", "2012", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.1", "24.1", "", "", "88.6", "80.0", "", "56.3", "", "2", "", "", "104", "1", "2", "95", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.9", "97.9", "", "", "", "", "96.2"]} +{"pcdb_id": 15892, "brand_name": "Worcester", "model_name": "Greenstar Danesmoor Wall-Mounted", "model_qualifier": "12/18", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 18.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015892", "000035", "0", "2020/Sep/08 10:00", "Bosch Thermotechnology", "Worcester", "Greenstar Danesmoor Wall-Mounted", "12/18", "", "2008", "2015", "4", "2", "1", "1", "0", "", "", "2", "3", "2", "12", "18", "", "", "87.9", "80.1", "", "58.5", "", "2", "", "", "201", "1", "1", "160", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.6", "94.7", "", "", "", "", "93.9"]} +{"pcdb_id": 15893, "brand_name": "Worcester", "model_name": "Greenstar Danesmoor Wall Mounted", "model_qualifier": "18/25", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 25.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015893", "000035", "0", "2020/Sep/08 10:00", "Bosch Thermotechnology", "Worcester", "Greenstar Danesmoor Wall Mounted", "18/25", "", "2008", "2015", "4", "2", "1", "1", "0", "", "", "2", "3", "2", "18", "25", "", "", "87.9", "80.1", "", "58.5", "", "2", "", "", "201", "1", "1", "160", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.3", "94.4", "", "", "", "", "93.8"]} +{"pcdb_id": 15894, "brand_name": "Fondital", "model_name": "Tahiti Dual HC 24 Line", "model_qualifier": "", "winter_efficiency_pct": 85.4, "summer_efficiency_pct": 76.8, "comparative_hot_water_efficiency_pct": 54.0, "output_kw_max": 24.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015894", "000250", "0", "2008/Aug/27 11:47", "Fondital", "Fondital", "Tahiti Dual HC 24 Line", "", "", "2008", "current", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "24.4", "24.4", "", "", "85.4", "76.8", "", "54.0", "", "2", "", "", "104", "1", "2", "142", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "86.3", "90.9", "", "", "", "", "90.0"]} +{"pcdb_id": 15895, "brand_name": "Fondital", "model_name": "Tahiti Dual HR 24 Line", "model_qualifier": "", "winter_efficiency_pct": 85.4, "summer_efficiency_pct": 76.4, "comparative_hot_water_efficiency_pct": 55.8, "output_kw_max": 24.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015895", "000250", "0", "2012/Mar/27 10:12", "Fondital", "Fondital", "Tahiti Dual HR 24 Line", "", "", "2008", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "24.4", "24.4", "", "", "85.4", "76.4", "", "55.8", "", "2", "", "", "102", "1", "2", "142", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "86.3", "90.9", "", "", "", "", "90.0"]} +{"pcdb_id": 15897, "brand_name": "Fondital", "model_name": "Tahiti Dual HRB 24 Line", "model_qualifier": "", "winter_efficiency_pct": 85.4, "summer_efficiency_pct": 76.4, "comparative_hot_water_efficiency_pct": 55.8, "output_kw_max": 24.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015897", "000250", "0", "2012/Mar/27 10:12", "Fondital", "Fondital", "Tahiti Dual HRB 24 Line", "", "", "2008", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "24.4", "24.4", "", "", "85.4", "76.4", "", "55.8", "", "2", "", "", "102", "1", "2", "142", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "86.3", "90.9", "", "", "", "", "90.0"]} +{"pcdb_id": 15898, "brand_name": "Alpha", "model_name": "CD 50 S", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 50.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015898", "000001", "0", "2012/Mar/27 10:12", "Alpha Therm", "Alpha", "CD 50 S", "", "", "2008", "current", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "50", "50", "", "", "88.8", "79.8", "", "58.3", "", "2", "1", "", "102", "1", "2", "180", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.7", "98.1", "", "", "", "", "96.7"]} +{"pcdb_id": 15899, "brand_name": "Alpha", "model_name": "CD 50 S", "model_qualifier": "", "winter_efficiency_pct": 87.8, "summer_efficiency_pct": 78.8, "comparative_hot_water_efficiency_pct": 57.6, "output_kw_max": 50.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015899", "000001", "0", "2012/Mar/27 10:12", "Alpha Therm", "Alpha", "CD 50 S", "", "", "2008", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "50", "50", "", "", "87.8", "78.8", "", "57.6", "", "2", "", "", "102", "1", "2", "180", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.7", "96.0", "", "", "", "", "94.6"]} +{"pcdb_id": 15900, "brand_name": "Alpha", "model_name": "CD 70 S", "model_qualifier": "", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 67.9, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015900", "000001", "0", "2012/Mar/27 10:12", "Alpha Therm", "Alpha", "CD 70 S", "", "", "2008", "current", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "67.9", "67.9", "", "", "89.0", "80.0", "", "58.4", "", "2", "1", "", "102", "1", "2", "270", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.6", "99.1", "", "", "", "", "97.3"]} +{"pcdb_id": 15901, "brand_name": "Alpha", "model_name": "CD 70 S", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 67.9, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015901", "000001", "0", "2012/Mar/27 10:12", "Alpha Therm", "Alpha", "CD 70 S", "", "", "2008", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "67.9", "67.9", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "270", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.7", "96.9", "", "", "", "", "95.2"]} +{"pcdb_id": 15902, "brand_name": "Fondital", "model_name": "Tahiti Dual HRB 24 Line", "model_qualifier": "", "winter_efficiency_pct": 86.4, "summer_efficiency_pct": 77.4, "comparative_hot_water_efficiency_pct": 56.5, "output_kw_max": 24.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015902", "000250", "0", "2012/Mar/27 10:12", "Fondital", "Fondital", "Tahiti Dual HRB 24 Line", "", "", "2008", "current", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "24.4", "24.4", "", "", "86.4", "77.4", "", "56.5", "", "2", "1", "", "102", "1", "2", "142", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.2", "92.9", "", "", "", "", "92.0"]} +{"pcdb_id": 15903, "brand_name": "Fondital", "model_name": "Tahiti Dual HR 24 Line", "model_qualifier": "", "winter_efficiency_pct": 86.4, "summer_efficiency_pct": 77.4, "comparative_hot_water_efficiency_pct": 56.5, "output_kw_max": 24.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015903", "000250", "0", "2012/Mar/27 10:12", "Fondital", "Fondital", "Tahiti Dual HR 24 Line", "", "", "2008", "current", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "24.4", "24.4", "", "", "86.4", "77.4", "", "56.5", "", "2", "1", "", "102", "1", "2", "142", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.2", "92.9", "", "", "", "", "92.0"]} +{"pcdb_id": 15904, "brand_name": "Fondital", "model_name": "Tahiti Dual HC 24 Line", "model_qualifier": "", "winter_efficiency_pct": 86.4, "summer_efficiency_pct": 77.8, "comparative_hot_water_efficiency_pct": 54.7, "output_kw_max": 24.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015904", "000250", "0", "2008/Aug/27 11:48", "Fondital", "Fondital", "Tahiti Dual HC 24 Line", "", "", "2008", "current", "2", "2", "1", "2", "0", "", "", "2", "3", "2", "24.4", "24.4", "", "", "86.4", "77.8", "", "54.7", "", "2", "1", "", "104", "1", "2", "142", "10", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.2", "92.9", "", "", "", "", "92.0"]} +{"pcdb_id": 15910, "brand_name": "HRM", "model_name": "Wallstar", "model_qualifier": "15/19 Condensing Eco", "winter_efficiency_pct": 83.2, "summer_efficiency_pct": 75.4, "comparative_hot_water_efficiency_pct": 55.1, "output_kw_max": 18.7, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015910", "000098", "0", "2012/Mar/27 10:12", "HRM Boilers", "HRM", "Wallstar", "15/19 Condensing Eco", "", "2007", "current", "4", "2", "1", "1", "0", "", "", "2", "2", "2", "15", "18.7", "", "", "83.2", "75.4", "", "55.1", "", "2", "", "", "201", "1", "1", "125", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "86.0", "88.2", "", "", "", "", "87.8"]} +{"pcdb_id": 15911, "brand_name": "HRM", "model_name": "Wallstar", "model_qualifier": "15/19 Condensing EOGB", "winter_efficiency_pct": 82.4, "summer_efficiency_pct": 74.6, "comparative_hot_water_efficiency_pct": 54.5, "output_kw_max": 18.8, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015911", "000098", "0", "2012/Mar/27 10:12", "HRM Boilers", "HRM", "Wallstar", "15/19 Condensing EOGB", "", "2007", "current", "4", "2", "1", "1", "0", "", "", "2", "2", "2", "15", "18.8", "", "", "82.4", "74.6", "", "54.5", "", "2", "", "", "201", "1", "1", "125", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "85.8", "86.9", "", "", "", "", "86.7"]} +{"pcdb_id": 15913, "brand_name": "HRM", "model_name": "Wallstar System", "model_qualifier": "15/19 Condensing Eco", "winter_efficiency_pct": 83.2, "summer_efficiency_pct": 75.4, "comparative_hot_water_efficiency_pct": 55.1, "output_kw_max": 19.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015913", "000098", "0", "2012/Mar/27 10:12", "HRM Boilers", "HRM", "Wallstar System", "15/19 Condensing Eco", "", "2007", "current", "4", "2", "1", "1", "0", "", "", "2", "2", "2", "15", "19", "", "", "83.2", "75.4", "", "55.1", "", "2", "", "", "201", "1", "1", "125", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "86.0", "88.2", "", "", "", "", "87.8"]} +{"pcdb_id": 15914, "brand_name": "HRM", "model_name": "Wallstar System", "model_qualifier": "15/19 Condensing EOGB", "winter_efficiency_pct": 82.4, "summer_efficiency_pct": 74.6, "comparative_hot_water_efficiency_pct": 54.5, "output_kw_max": 19.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015914", "000098", "0", "2012/Mar/27 10:12", "HRM Boilers", "HRM", "Wallstar System", "15/19 Condensing EOGB", "", "2007", "current", "4", "2", "1", "1", "0", "", "", "2", "2", "2", "15", "19", "", "", "82.4", "74.6", "", "54.5", "", "2", "", "", "201", "1", "1", "125", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "85.8", "86.9", "", "", "", "", "86.7"]} +{"pcdb_id": 15915, "brand_name": "HRM", "model_name": "X-Ternal", "model_qualifier": "15/19 Condensing Eco", "winter_efficiency_pct": 83.2, "summer_efficiency_pct": 75.4, "comparative_hot_water_efficiency_pct": 55.1, "output_kw_max": 18.7, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015915", "000098", "0", "2012/Mar/27 10:12", "HRM Boilers", "HRM", "X-Ternal", "15/19 Condensing Eco", "", "2007", "current", "4", "2", "2", "1", "0", "", "", "2", "2", "2", "15", "18.7", "", "", "83.2", "75.4", "", "55.1", "", "2", "", "", "201", "1", "1", "125", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "86.0", "88.2", "", "", "", "", "87.8"]} +{"pcdb_id": 15916, "brand_name": "HRM", "model_name": "X-Ternal", "model_qualifier": "15/19 Condensing EOGB", "winter_efficiency_pct": 82.4, "summer_efficiency_pct": 74.6, "comparative_hot_water_efficiency_pct": 54.5, "output_kw_max": 18.7, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015916", "000098", "0", "2012/Mar/27 10:12", "HRM Boilers", "HRM", "X-Ternal", "15/19 Condensing EOGB", "", "2007", "current", "4", "2", "2", "1", "0", "", "", "2", "2", "2", "15", "18.7", "", "", "82.4", "74.6", "", "54.5", "", "2", "", "", "201", "1", "1", "125", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "85.8", "86.9", "", "", "", "", "86.7"]} +{"pcdb_id": 15917, "brand_name": "HRM", "model_name": "Wallstar", "model_qualifier": "20/24 Condensing Eco", "winter_efficiency_pct": 82.4, "summer_efficiency_pct": 74.6, "comparative_hot_water_efficiency_pct": 54.5, "output_kw_max": 24.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015917", "000098", "0", "2012/Mar/27 10:12", "HRM Boilers", "HRM", "Wallstar", "20/24 Condensing Eco", "", "2007", "current", "4", "2", "1", "1", "0", "", "", "2", "2", "2", "20", "24", "", "", "82.4", "74.6", "", "54.5", "", "2", "", "", "201", "1", "1", "125", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "86.1", "86.5", "", "", "", "", "86.4"]} +{"pcdb_id": 15919, "brand_name": "HRM", "model_name": "Wallstar", "model_qualifier": "20/24 Condensing EOGB", "winter_efficiency_pct": 82.4, "summer_efficiency_pct": 74.6, "comparative_hot_water_efficiency_pct": 54.5, "output_kw_max": 24.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015919", "000098", "0", "2012/Mar/27 10:12", "HRM Boilers", "HRM", "Wallstar", "20/24 Condensing EOGB", "", "2007", "current", "4", "2", "1", "1", "0", "", "", "2", "2", "2", "20", "24", "", "", "82.4", "74.6", "", "54.5", "", "2", "", "", "201", "1", "1", "125", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "85.4", "87.2", "", "", "", "", "86.9"]} +{"pcdb_id": 15921, "brand_name": "Grant", "model_name": "Vortex Eco Wall Hung 12-16", "model_qualifier": "", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 81.3, "comparative_hot_water_efficiency_pct": 59.4, "output_kw_max": 16.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015921", "000048", "0", "2012/Mar/27 10:12", "Grant Engineering (UK)", "Grant", "Vortex Eco Wall Hung 12-16", "", "", "2008", "current", "4", "2", "1", "1", "0", "", "", "2", "3", "2", "12", "16", "", "", "89.1", "81.3", "", "59.4", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "93.1", "96.7", "", "", "", "", "96.0"]} +{"pcdb_id": 15922, "brand_name": "Grant", "model_name": "Vortex Eco Wall Hung 16-21", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 59.2, "output_kw_max": 21.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015922", "000048", "0", "2012/Mar/27 10:12", "Grant Engineering (UK)", "Grant", "Vortex Eco Wall Hung 16-21", "", "", "2008", "current", "4", "2", "1", "1", "0", "", "", "2", "3", "2", "16", "21", "", "", "88.8", "81.0", "", "59.2", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.8", "96.9", "", "", "", "", "95.7"]} +{"pcdb_id": 15923, "brand_name": "Grant", "model_name": "Vortex Eco Wall Hung System 12-16", "model_qualifier": "", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 81.3, "comparative_hot_water_efficiency_pct": 59.4, "output_kw_max": 21.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015923", "000048", "0", "2012/Mar/27 10:12", "Grant Engineering (UK)", "Grant", "Vortex Eco Wall Hung System 12-16", "", "", "2008", "current", "4", "2", "1", "1", "0", "", "", "2", "3", "2", "16", "21", "", "", "89.1", "81.3", "", "59.4", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "93.1", "96.7", "", "", "", "", "96.0"]} +{"pcdb_id": 15924, "brand_name": "Grant", "model_name": "Vortex Eco Wall Hung System 16-21", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 59.2, "output_kw_max": 21.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015924", "000048", "0", "2012/Mar/27 10:12", "Grant Engineering (UK)", "Grant", "Vortex Eco Wall Hung System 16-21", "", "", "2008", "current", "4", "2", "1", "1", "0", "", "", "2", "3", "2", "16", "21", "", "", "88.8", "81.0", "", "59.2", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.8", "96.9", "", "", "", "", "95.7"]} +{"pcdb_id": 15925, "brand_name": "Grant", "model_name": "Vortex Eco Wall Hung External 12-16", "model_qualifier": "", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 81.3, "comparative_hot_water_efficiency_pct": 59.4, "output_kw_max": 16.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015925", "000048", "0", "2012/Mar/27 10:12", "Grant Engineering (UK)", "Grant", "Vortex Eco Wall Hung External 12-16", "", "", "2008", "current", "4", "2", "2", "1", "0", "", "", "2", "3", "2", "12", "16", "", "", "89.1", "81.3", "", "59.4", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "93.1", "96.7", "", "", "", "", "96.0"]} +{"pcdb_id": 15926, "brand_name": "Grant", "model_name": "Vortex Eco Wall Hung External 16-21", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 59.2, "output_kw_max": 21.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015926", "000048", "0", "2012/Mar/27 10:12", "Grant Engineering (UK)", "Grant", "Vortex Eco Wall Hung External 16-21", "", "", "2008", "current", "4", "2", "2", "1", "0", "", "", "2", "3", "2", "16", "21", "", "", "88.8", "81.0", "", "59.2", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.8", "96.9", "", "", "", "", "95.7"]} +{"pcdb_id": 15927, "brand_name": "Grant", "model_name": "Vortex Eco Wall Hung External System 12-16", "model_qualifier": "", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 81.3, "comparative_hot_water_efficiency_pct": 59.4, "output_kw_max": 16.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015927", "000048", "0", "2012/Mar/27 10:12", "Grant Engineering (UK)", "Grant", "Vortex Eco Wall Hung External System 12-16", "", "", "2008", "current", "4", "2", "2", "1", "0", "", "", "2", "3", "2", "12", "16", "", "", "89.1", "81.3", "", "59.4", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "93.1", "96.7", "", "", "", "", "96.0"]} +{"pcdb_id": 15928, "brand_name": "Grant", "model_name": "Vortex Eco Wall Hung External System 16-21", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 59.2, "output_kw_max": 21.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015928", "000048", "0", "2012/Mar/27 10:12", "Grant Engineering (UK)", "Grant", "Vortex Eco Wall Hung External System 16-21", "", "", "2008", "current", "4", "2", "2", "1", "0", "", "", "2", "3", "2", "16", "21", "", "", "88.8", "81.0", "", "59.2", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.8", "96.9", "", "", "", "", "95.7"]} +{"pcdb_id": 15929, "brand_name": "Grant", "model_name": "Vortex Eco", "model_qualifier": "Utility 15-21", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 20.7, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015929", "000048", "0", "2012/Mar/27 10:12", "Grant Engineering (UK)", "Grant", "Vortex Eco", "Utility 15-21", "", "2008", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "15", "20.7", "", "", "88.0", "80.2", "", "58.6", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.5", "94.4", "", "", "", "", "93.9"]} +{"pcdb_id": 15930, "brand_name": "Grant", "model_name": "Vortex Eco", "model_qualifier": "Utility 21-26", "winter_efficiency_pct": 87.8, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 25.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015930", "000048", "0", "2012/Mar/27 10:12", "Grant Engineering (UK)", "Grant", "Vortex Eco", "Utility 21-26", "", "2008", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "20.7", "25.6", "", "", "87.8", "80.0", "", "58.4", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.4", "94.4", "", "", "", "", "93.6"]} +{"pcdb_id": 15931, "brand_name": "Grant", "model_name": "Vortex Eco", "model_qualifier": "Utility 26-35", "winter_efficiency_pct": 87.5, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 34.7, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015931", "000048", "0", "2012/Mar/27 10:12", "Grant Engineering (UK)", "Grant", "Vortex Eco", "Utility 26-35", "", "2008", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "25.6", "34.7", "", "", "87.5", "79.7", "", "58.2", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.3", "93.8", "", "", "", "", "93.1"]} +{"pcdb_id": 15932, "brand_name": "Grant", "model_name": "Vortex Eco", "model_qualifier": "External 15-21", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 20.7, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015932", "000048", "0", "2012/Mar/27 10:12", "Grant Engineering (UK)", "Grant", "Vortex Eco", "External 15-21", "", "2008", "current", "4", "1", "2", "1", "0", "", "", "2", "3", "2", "15", "20.7", "", "", "88.0", "80.2", "", "58.6", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.5", "94.4", "", "", "", "", "93.9"]} +{"pcdb_id": 15933, "brand_name": "Grant", "model_name": "Vortex Eco", "model_qualifier": "External 21-26", "winter_efficiency_pct": 87.8, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 25.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015933", "000048", "0", "2012/Mar/27 10:12", "Grant Engineering (UK)", "Grant", "Vortex Eco", "External 21-26", "", "2008", "current", "4", "1", "2", "1", "0", "", "", "2", "3", "2", "20.7", "25.6", "", "", "87.8", "80.0", "", "58.4", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.4", "94.4", "", "", "", "", "93.6"]} +{"pcdb_id": 15934, "brand_name": "Grant", "model_name": "Vortex Eco", "model_qualifier": "External 26-35", "winter_efficiency_pct": 87.5, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 34.7, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015934", "000048", "0", "2012/Mar/27 10:12", "Grant Engineering (UK)", "Grant", "Vortex Eco", "External 26-35", "", "2008", "current", "4", "1", "2", "1", "0", "", "", "2", "3", "2", "25.6", "34.7", "", "", "87.5", "79.7", "", "58.2", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.3", "93.8", "", "", "", "", "93.1"]} +{"pcdb_id": 15935, "brand_name": "Worcester", "model_name": "Greenstar Highflow", "model_qualifier": "440 CDi", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 86.9, "comparative_hot_water_efficiency_pct": 49.0, "output_kw_max": 29.2, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 1, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0084, "loss_factor_f1_kwh_per_day": 4.47444, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015935", "000035", "0", "2020/Sep/08 10:00", "Bosch Thermotechnology", "Worcester", "Greenstar Highflow", "440 CDi", "47 406 24", "2008", "2015", "1", "1", "1", "2", "0", "", "", "2", "2", "2", "29.2", "29.2", "", "", "88.2", "86.9", "", "49.0", "", "2", "", "", "106", "1", "2", "164", "10", "1", "1", "0", "47", "0", "25", "3", "65", "", "1", "10.7537", "0.4102", "0.0084", "4.47444", "", "", "", "", "", "", "", "", "0305", "", "", "", "", "", "", "", "", "88.6", "97.1", "", "", "", "", "95.5"]} +{"pcdb_id": 15936, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "FS 42 CDi Regular", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 40.8, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015936", "000035", "0", "2020/Sep/08 10:00", "Bosch Thermotechnology", "Worcester", "Greenstar", "FS 42 CDi Regular", "41 406 04", "2008", "2015", "1", "1", "1", "1", "0", "", "", "2", "2", "2", "40.8", "40.8", "", "", "88.1", "79.1", "", "57.8", "", "2", "", "", "102", "1", "2", "80", "9", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.1", "97.0", "", "", "", "", "95.3"]} +{"pcdb_id": 15938, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "FS 42 CDi Regular", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 40.8, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015938", "000035", "0", "2020/Sep/08 10:01", "Bosch Thermotechnology", "Worcester", "Greenstar", "FS 42 CDi Regular", "41 406 06", "2008", "2015", "2", "1", "1", "1", "0", "", "", "2", "2", "2", "40.8", "40.8", "", "", "89.1", "80.1", "", "58.5", "", "2", "1", "", "102", "1", "2", "80", "9", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.1", "99.2", "", "", "", "", "97.5"]} +{"pcdb_id": 15939, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "FS 30 CDi Regular", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 30.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015939", "000035", "0", "2020/Sep/08 10:01", "Bosch Thermotechnology", "Worcester", "Greenstar", "FS 30 CDi Regular", "41 406 03", "2008", "2015", "1", "1", "1", "1", "0", "", "", "2", "2", "2", "30", "30", "", "", "88.2", "79.2", "", "57.9", "", "2", "", "", "102", "1", "2", "60", "9", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.6", "97.1", "", "", "", "", "95.5"]} +{"pcdb_id": 15940, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "FS 30 CDi Regular", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 30.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015940", "000035", "0", "2020/Sep/08 10:01", "Bosch Thermotechnology", "Worcester", "Greenstar", "FS 30 CDi Regular", "41 406 05", "2008", "2015", "2", "1", "1", "1", "0", "", "", "2", "2", "2", "30", "30", "", "", "89.2", "80.2", "", "58.6", "", "2", "1", "", "102", "1", "2", "60", "9", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.5", "99.3", "", "", "", "", "97.6"]} +{"pcdb_id": 15941, "brand_name": "Worcester", "model_name": "Greenstar Highflow", "model_qualifier": "550 CDi", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 86.9, "comparative_hot_water_efficiency_pct": 49.1, "output_kw_max": 30.6, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 1, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.007, "loss_factor_f1_kwh_per_day": 4.4537, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015941", "000035", "0", "2020/Sep/08 10:01", "Bosch Thermotechnology", "Worcester", "Greenstar Highflow", "550 CDi", "47 406 25", "2008", "2015", "1", "1", "1", "2", "0", "", "", "2", "2", "2", "30.6", "30.6", "", "", "88.2", "86.9", "", "49.1", "", "2", "", "", "106", "1", "2", "206", "10", "1", "1", "0", "47", "0", "25", "3", "65", "", "1", "10.7237", "0.3495", "0.007", "4.4537", "", "", "", "", "", "0", "0", "", "0305", "", "", "", "", "", "", "", "", "88.6", "97.1", "", "", "", "", "95.5"]} +{"pcdb_id": 15942, "brand_name": "Worcester", "model_name": "Greenstar Highflow", "model_qualifier": "550 CDi", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 81.9, "comparative_hot_water_efficiency_pct": 44.3, "output_kw_max": 30.6, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 1, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015942", "000035", "0", "2024/Jan/31 10:17", "Bosch Thermotechnology", "Worcester", "Greenstar Highflow", "550 CDi", "47 406 27", "2008", "2015", "2", "1", "1", "2", "0", "", "", "2", "2", "2", "30.6", "30.6", "", "", "89.2", "81.9", "", "44.3", "", "2", "1", "", "106", "1", "2", "206", "10", "1", "1", "0", "47", "0", "25", "3", "65", "", "0", "", "", "", "", "", "", "", "", "", "0", "0", "", "8305", "", "", "", "", "", "", "", "", "90.5", "99.3", "", "", "", "", "97.6"]} +{"pcdb_id": 15943, "brand_name": "Worcester", "model_name": "Greenstar Highflow", "model_qualifier": "440 CDi", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 81.9, "comparative_hot_water_efficiency_pct": 44.3, "output_kw_max": 29.2, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 1, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015943", "000035", "0", "2024/Jan/31 10:17", "Bosch Thermotechnology", "Worcester", "Greenstar Highflow", "440 CDi", "47 406 26", "2008", "2015", "2", "1", "1", "2", "0", "", "", "2", "2", "2", "29.2", "29.2", "", "", "89.2", "81.9", "", "44.3", "", "2", "1", "", "106", "1", "2", "164", "10", "1", "1", "0", "47", "0", "25", "3", "65", "", "0", "", "", "", "", "", "", "", "", "", "0", "0", "", "8305", "", "", "", "", "", "", "", "", "90.5", "99.3", "", "", "", "", "97.6"]} +{"pcdb_id": 15944, "brand_name": "HRM", "model_name": "Wallstar", "model_qualifier": "Combi", "winter_efficiency_pct": 85.9, "summer_efficiency_pct": 78.5, "comparative_hot_water_efficiency_pct": 55.2, "output_kw_max": 24.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015944", "000098", "0", "2008/Sep/30 08:09", "HRM Boilers", "HRM", "Wallstar", "Combi", "", "2008", "current", "4", "2", "1", "2", "0", "", "", "2", "2", "2", "18", "24", "", "", "85.9", "78.5", "", "55.2", "", "2", "", "", "202", "1", "1", "125", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "89.4", "90.1", "", "", "", "", "90.0"]} +{"pcdb_id": 15945, "brand_name": "Firebird", "model_name": "Enviromax Popular C20kW", "model_qualifier": "", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 81.2, "comparative_hot_water_efficiency_pct": 59.3, "output_kw_max": 20.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015945", "000047", "0", "2012/Mar/27 10:12", "Firebird Boilers", "Firebird", "Enviromax Popular C20kW", "", "", "2008", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "15", "20", "", "", "89.0", "81.2", "", "59.3", "", "2", "", "", "201", "1", "1", "38", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "93.3", "96.2", "", "", "", "", "95.7"]} +{"pcdb_id": 15947, "brand_name": "Ariston", "model_name": "Clas HE R 24", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 24.1, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015947", "000080", "0", "2015/Apr/09 12:40", "Merloni TermoSanitari", "Ariston", "Clas HE R 24", "", "41-116-32", "2008", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24.1", "24.1", "", "", "88.3", "79.3", "", "57.9", "", "2", "", "", "102", "1", "2", "144", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "97.3", "", "", "", "", "95.6"]} +{"pcdb_id": 15948, "brand_name": "Ariston", "model_name": "Clas HE R 18", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 17.6, "final_year_of_manufacture": 2013, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015948", "000080", "0", "2013/Nov/04 15:24", "Merloni TermoSanitari", "Ariston", "Clas HE R 18", "", "41-116-31", "2008", "2013", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "17.6", "17.6", "", "", "88.6", "79.6", "", "58.1", "", "2", "", "", "102", "1", "2", "142", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "98.2", "", "", "", "", "96.3"]} +{"pcdb_id": 15949, "brand_name": "Ariston", "model_name": "Clas HE R 12", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 11.7, "final_year_of_manufacture": 2013, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015949", "000080", "0", "2013/Nov/04 15:25", "Merloni TermoSanitari", "Ariston", "Clas HE R 12", "", "41-116-30", "2008", "2013", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "11.7", "11.7", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "135", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "97.9", "", "", "", "", "96.0"]} +{"pcdb_id": 15950, "brand_name": "Biasi", "model_name": "Riva Advance HE", "model_qualifier": "M110B.24SR/C", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 25.1, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015950", "000208", "0", "2013/Feb/27 12:41", "Biasi", "Biasi", "Riva Advance HE", "M110B.24SR/C", "41-583-07", "2008", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "25.1", "25.1", "", "", "88.5", "79.5", "", "58.0", "", "2", "", "", "102", "1", "2", "108", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.1", "97.9", "", "", "", "", "96.1"]} +{"pcdb_id": 15951, "brand_name": "Biasi", "model_name": "Riva Advance HE", "model_qualifier": "M110B.24SR/C", "winter_efficiency_pct": 89.5, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 58.8, "output_kw_max": 25.1, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015951", "000208", "0", "2012/Mar/27 10:12", "Biasi", "Biasi", "Riva Advance HE", "M110B.24SR/C", "", "2008", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "25.1", "25.1", "", "", "89.5", "80.5", "", "58.8", "", "2", "1", "", "102", "1", "2", "108", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.1", "100.1", "", "", "", "", "98.2"]} +{"pcdb_id": 15952, "brand_name": "Intergas", "model_name": "Combi Compact HRE 36/30", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 87.0, "comparative_hot_water_efficiency_pct": 74.4, "output_kw_max": 26.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0009, "loss_factor_f1_kwh_per_day": 0.98426, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015952", "000256", "0", "2014/Dec/01 15:12", "Intergas Verwarming", "Intergas", "Combi Compact HRE 36/30", "", "47-291-03", "2008", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "26.6", "26.6", "", "", "88.5", "87.0", "", "74.4", "", "2", "", "", "104", "1", "2", "130", "1.9", "0", "", "", "0", "0", "", "", "", "", "1", "7.079", "0.05", "0.0009", "0.98426", "", "", "", "", "", "1", "0", "", "0005", "", "", "", "", "", "", "", "", "88.9", "97.6", "", "", "", "", "95.9"]} +{"pcdb_id": 15953, "brand_name": "Firebird", "model_name": "Enviromax Systempac C35kW", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 59.0, "output_kw_max": 35.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015953", "000047", "0", "2012/Mar/27 10:12", "Firebird Boilers", "Firebird", "Enviromax Systempac C35kW", "", "", "2008", "current", "4", "1", "2", "1", "0", "", "", "2", "1", "1", "26", "35", "", "", "88.6", "80.8", "", "59.0", "", "2", "", "", "201", "1", "1", "38", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "93.5", "95.3", "", "", "", "", "95.0"]} +{"pcdb_id": 15954, "brand_name": "Firebird", "model_name": "Enviromax Systempac C26kW", "model_qualifier": "", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 81.2, "comparative_hot_water_efficiency_pct": 59.3, "output_kw_max": 26.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015954", "000047", "0", "2012/Mar/27 10:12", "Firebird Boilers", "Firebird", "Enviromax Systempac C26kW", "", "", "2008", "current", "4", "1", "2", "1", "0", "", "", "2", "1", "1", "15", "26", "", "", "89.0", "81.2", "", "59.3", "", "2", "", "", "201", "1", "1", "38", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "93.2", "96.4", "", "", "", "", "95.8"]} +{"pcdb_id": 15955, "brand_name": "Firebird", "model_name": "Enviromax Systempac C20kW", "model_qualifier": "", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 81.2, "comparative_hot_water_efficiency_pct": 59.3, "output_kw_max": 20.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015955", "000047", "0", "2012/Mar/27 10:12", "Firebird Boilers", "Firebird", "Enviromax Systempac C20kW", "", "", "2008", "current", "4", "1", "2", "1", "0", "", "", "2", "1", "1", "15", "20", "", "", "89.0", "81.2", "", "59.3", "", "2", "", "", "201", "1", "1", "38", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "93.3", "96.2", "", "", "", "", "95.7"]} +{"pcdb_id": 15956, "brand_name": "Firebird", "model_name": "Enviromax Combipac C20kW", "model_qualifier": "", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 82.9, "comparative_hot_water_efficiency_pct": 50.7, "output_kw_max": 20.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015956", "000047", "0", "2024/Jan/31 10:17", "Firebird Boilers", "Firebird", "Enviromax Combipac C20kW", "", "", "2008", "current", "4", "1", "2", "2", "0", "", "", "2", "1", "1", "15", "20", "", "", "89.0", "82.9", "", "50.7", "", "2", "", "", "203", "1", "1", "38", "0", "2", "", "0", "40", "0", "25", "1", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "93.3", "96.2", "", "", "", "", "95.7"]} +{"pcdb_id": 15957, "brand_name": "Firebird", "model_name": "Enviromax Combipac C26kW", "model_qualifier": "", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 82.9, "comparative_hot_water_efficiency_pct": 50.8, "output_kw_max": 26.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015957", "000047", "0", "2024/Jan/31 10:17", "Firebird Boilers", "Firebird", "Enviromax Combipac C26kW", "", "", "2008", "current", "4", "1", "2", "2", "0", "", "", "2", "1", "1", "15", "26", "", "", "89.0", "82.9", "", "50.8", "", "2", "", "", "203", "1", "1", "38", "0", "2", "", "0", "40", "0", "25", "1", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "93.2", "96.4", "", "", "", "", "95.8"]} +{"pcdb_id": 15958, "brand_name": "Firebird", "model_name": "Enviromax Combipac C35kW", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 82.5, "comparative_hot_water_efficiency_pct": 50.5, "output_kw_max": 35.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015958", "000047", "0", "2024/Jan/31 10:17", "Firebird Boilers", "Firebird", "Enviromax Combipac C35kW", "", "", "2008", "current", "4", "1", "2", "2", "0", "", "", "2", "1", "1", "26", "35", "", "", "88.6", "82.5", "", "50.5", "", "2", "", "", "203", "1", "1", "38", "0", "2", "", "0", "40", "0", "25", "1", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "93.5", "95.3", "", "", "", "", "95.0"]} +{"pcdb_id": 15959, "brand_name": "Firebird", "model_name": "Enviromax Combi C20kW", "model_qualifier": "", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 82.9, "comparative_hot_water_efficiency_pct": 50.7, "output_kw_max": 20.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015959", "000047", "0", "2024/Jan/31 10:17", "Firebird Boilers", "Firebird", "Enviromax Combi C20kW", "", "", "2008", "current", "4", "1", "1", "2", "0", "", "", "2", "3", "1", "15", "20", "", "", "89.0", "82.9", "", "50.7", "", "2", "", "", "203", "1", "1", "38", "0", "2", "", "0", "40", "0", "25", "1", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "93.3", "96.2", "", "", "", "", "95.7"]} +{"pcdb_id": 15960, "brand_name": "Firebird", "model_name": "Enviromax Combi C26kW", "model_qualifier": "", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 82.9, "comparative_hot_water_efficiency_pct": 50.8, "output_kw_max": 26.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015960", "000047", "0", "2024/Jan/31 10:17", "Firebird Boilers", "Firebird", "Enviromax Combi C26kW", "", "", "2008", "current", "4", "1", "1", "2", "0", "", "", "2", "3", "1", "15", "26", "", "", "89.0", "82.9", "", "50.8", "", "2", "", "", "203", "1", "1", "38", "0", "2", "", "0", "40", "0", "25", "1", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "93.2", "96.4", "", "", "", "", "95.8"]} +{"pcdb_id": 15961, "brand_name": "Firebird", "model_name": "Enviromax Combi C35kW", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 82.5, "comparative_hot_water_efficiency_pct": 50.5, "output_kw_max": 35.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015961", "000047", "0", "2024/Jan/31 10:17", "Firebird Boilers", "Firebird", "Enviromax Combi C35kW", "", "", "2008", "current", "4", "1", "1", "2", "0", "", "", "2", "3", "1", "26", "35", "", "", "88.6", "82.5", "", "50.5", "", "2", "", "", "203", "1", "1", "38", "0", "2", "", "0", "40", "0", "25", "1", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "93.5", "95.3", "", "", "", "", "95.0"]} +{"pcdb_id": 15962, "brand_name": "Firebird", "model_name": "Enviromax System C20kW", "model_qualifier": "", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 81.2, "comparative_hot_water_efficiency_pct": 59.3, "output_kw_max": 20.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015962", "000047", "0", "2012/Mar/27 10:12", "Firebird Boilers", "Firebird", "Enviromax System C20kW", "", "", "2008", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "15", "20", "", "", "89.0", "81.2", "", "59.3", "", "2", "", "", "201", "1", "1", "38", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "93.3", "96.2", "", "", "", "", "95.7"]} +{"pcdb_id": 15963, "brand_name": "Firebird", "model_name": "Enviromax System C26kW", "model_qualifier": "", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 81.2, "comparative_hot_water_efficiency_pct": 59.3, "output_kw_max": 26.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015963", "000047", "0", "2012/Mar/27 10:12", "Firebird Boilers", "Firebird", "Enviromax System C26kW", "", "", "2008", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "15", "26", "", "", "89.0", "81.2", "", "59.3", "", "2", "", "", "201", "1", "1", "38", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "93.2", "96.4", "", "", "", "", "95.8"]} +{"pcdb_id": 15964, "brand_name": "Firebird", "model_name": "Enviromax System C35kW", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 59.0, "output_kw_max": 35.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015964", "000047", "0", "2012/Mar/27 10:12", "Firebird Boilers", "Firebird", "Enviromax System C35kW", "", "", "2008", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "26", "35", "", "", "88.6", "80.8", "", "59.0", "", "2", "", "", "201", "1", "1", "38", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "93.5", "95.3", "", "", "", "", "95.0"]} +{"pcdb_id": 15965, "brand_name": "Firebird", "model_name": "Enviromax Popular C26kW", "model_qualifier": "", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 81.2, "comparative_hot_water_efficiency_pct": 59.3, "output_kw_max": 26.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015965", "000047", "0", "2012/Mar/27 10:12", "Firebird Boilers", "Firebird", "Enviromax Popular C26kW", "", "", "2008", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "15", "26", "", "", "89.0", "81.2", "", "59.3", "", "2", "", "", "201", "1", "1", "38", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "93.2", "96.4", "", "", "", "", "95.8"]} +{"pcdb_id": 15966, "brand_name": "Firebird", "model_name": "Enviromax Popular C35kW", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 59.0, "output_kw_max": 35.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015966", "000047", "0", "2012/Mar/27 10:12", "Firebird Boilers", "Firebird", "Enviromax Popular C35kW", "", "", "2008", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "26", "35", "", "", "88.6", "80.8", "", "59.0", "", "2", "", "", "201", "1", "1", "38", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "93.5", "95.3", "", "", "", "", "95.0"]} +{"pcdb_id": 15967, "brand_name": "Firebird", "model_name": "Enviromax Heatpac C20kW", "model_qualifier": "", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 81.2, "comparative_hot_water_efficiency_pct": 59.3, "output_kw_max": 20.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015967", "000047", "0", "2012/Mar/27 10:12", "Firebird Boilers", "Firebird", "Enviromax Heatpac C20kW", "", "", "2008", "current", "4", "1", "2", "1", "0", "", "", "2", "1", "1", "15", "20", "", "", "89.0", "81.2", "", "59.3", "", "2", "", "", "201", "1", "1", "38", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "93.3", "96.2", "", "", "", "", "95.7"]} +{"pcdb_id": 15968, "brand_name": "Firebird", "model_name": "Enviromax Heatpac C26kW", "model_qualifier": "", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 81.2, "comparative_hot_water_efficiency_pct": 59.3, "output_kw_max": 26.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015968", "000047", "0", "2012/Mar/27 10:12", "Firebird Boilers", "Firebird", "Enviromax Heatpac C26kW", "", "", "2008", "current", "4", "1", "2", "1", "0", "", "", "2", "1", "1", "15", "26", "", "", "89.0", "81.2", "", "59.3", "", "2", "", "", "201", "1", "1", "38", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "93.2", "96.4", "", "", "", "", "95.8"]} +{"pcdb_id": 15969, "brand_name": "Firebird", "model_name": "Enviromax Heatpac C35kW", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 59.0, "output_kw_max": 35.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015969", "000047", "0", "2012/Mar/27 10:12", "Firebird Boilers", "Firebird", "Enviromax Heatpac C35kW", "", "", "2008", "current", "4", "1", "2", "1", "0", "", "", "2", "1", "1", "26", "35", "", "", "88.6", "80.8", "", "59.0", "", "2", "", "", "201", "1", "1", "38", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "93.5", "95.3", "", "", "", "", "95.0"]} +{"pcdb_id": 15970, "brand_name": "Firebird", "model_name": "Enviromax Utility C35kW", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 59.0, "output_kw_max": 35.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015970", "000047", "0", "2012/Jun/28 11:04", "Firebird Boilers", "Firebird", "Enviromax Utility C35kW", "", "", "2008", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "26", "35", "", "", "88.6", "80.8", "", "59.0", "", "2", "", "", "201", "1", "1", "38", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "93.5", "95.3", "", "", "", "", "95.0"]} +{"pcdb_id": 15971, "brand_name": "Firebird", "model_name": "Enviromax Utility C26kW", "model_qualifier": "", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 81.2, "comparative_hot_water_efficiency_pct": 59.3, "output_kw_max": 26.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015971", "000047", "0", "2012/Jun/28 11:04", "Firebird Boilers", "Firebird", "Enviromax Utility C26kW", "", "", "2008", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "15", "26", "", "", "89.0", "81.2", "", "59.3", "", "2", "", "", "201", "1", "1", "38", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "93.2", "96.4", "", "", "", "", "95.8"]} +{"pcdb_id": 15972, "brand_name": "Firebird", "model_name": "Enviromax Utility C20kW", "model_qualifier": "", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 81.2, "comparative_hot_water_efficiency_pct": 59.3, "output_kw_max": 20.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015972", "000047", "0", "2012/Jun/28 11:04", "Firebird Boilers", "Firebird", "Enviromax Utility C20kW", "", "", "2008", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "15", "20", "", "", "89.0", "81.2", "", "59.3", "", "2", "", "", "201", "1", "1", "38", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "93.3", "96.2", "", "", "", "", "95.7"]} +{"pcdb_id": 15973, "brand_name": "Firebird", "model_name": "Enviromax Kitchen C20kW", "model_qualifier": "", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 81.2, "comparative_hot_water_efficiency_pct": 59.3, "output_kw_max": 20.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015973", "000047", "0", "2012/Mar/27 10:12", "Firebird Boilers", "Firebird", "Enviromax Kitchen C20kW", "", "", "2008", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "15", "20", "", "", "89.0", "81.2", "", "59.3", "", "2", "", "", "201", "1", "1", "38", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "93.3", "96.2", "", "", "", "", "95.7"]} +{"pcdb_id": 15974, "brand_name": "Firebird", "model_name": "Enviromax Kitchen C26kW", "model_qualifier": "", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 81.2, "comparative_hot_water_efficiency_pct": 59.3, "output_kw_max": 26.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015974", "000047", "0", "2012/Mar/27 10:12", "Firebird Boilers", "Firebird", "Enviromax Kitchen C26kW", "", "", "2008", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "15", "26", "", "", "89.0", "81.2", "", "59.3", "", "2", "", "", "201", "1", "1", "38", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "93.2", "96.4", "", "", "", "", "95.8"]} +{"pcdb_id": 15975, "brand_name": "Firebird", "model_name": "Enviromax Kitchen C35kW", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 59.0, "output_kw_max": 35.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015975", "000047", "0", "2012/Mar/27 10:12", "Firebird Boilers", "Firebird", "Enviromax Kitchen C35kW", "", "", "2008", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "26", "35", "", "", "88.6", "80.8", "", "59.0", "", "2", "", "", "201", "1", "1", "38", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "93.5", "95.3", "", "", "", "", "95.0"]} +{"pcdb_id": 15977, "brand_name": "Viessmann", "model_name": "Vitodens 100 W WB1B", "model_qualifier": "26kW Combi Boiler", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 62.3, "output_kw_max": 23.7, "final_year_of_manufacture": 2012, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015977", "000033", "0", "2010/Sep/29 12:25", "Viessmann", "Viessmann", "Vitodens 100 W WB1B", "26kW Combi Boiler", "GC No 47-819-18", "2008", "2012", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "23.7", "23.7", "", "", "88.4", "79.8", "", "62.3", "", "2", "", "", "104", "1", "2", "111", "7", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "", "0005", "", "", "", "", "", "", "", "", "87.8", "97.8", "", "", "", "", "95.9"]} +{"pcdb_id": 15978, "brand_name": "Viessmann", "model_name": "Vitodens 100 W WB1B", "model_qualifier": "26kw Combi Boiler", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 63.1, "output_kw_max": 23.7, "final_year_of_manufacture": 2012, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015978", "000033", "0", "2008/Nov/24 09:32", "Viessmann", "Viessmann", "Vitodens 100 W WB1B", "26kw Combi Boiler", "", "2008", "2012", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "23.7", "23.7", "", "", "89.4", "80.8", "", "63.1", "", "2", "1", "", "104", "1", "2", "111", "7", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "", "0005", "", "", "", "", "", "", "", "", "89.8", "100.0", "", "", "", "", "98.1"]} +{"pcdb_id": 15979, "brand_name": "Viessmann", "model_name": "Vitodens 100 W WB1B", "model_qualifier": "30kW Combi Boiler", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 62.5, "output_kw_max": 23.7, "final_year_of_manufacture": 2012, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015979", "000033", "0", "2010/Sep/29 12:25", "Viessmann", "Viessmann", "Vitodens 100 W WB1B", "30kW Combi Boiler", "GC No. 47-819-19", "2008", "2012", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "23.7", "23.7", "", "", "88.7", "80.1", "", "62.5", "", "2", "", "", "104", "1", "2", "125", "7", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "", "0005", "", "", "", "", "", "", "", "", "88.5", "98.3", "", "", "", "", "96.4"]} +{"pcdb_id": 15980, "brand_name": "Viessmann", "model_name": "Vitodens 100 W WB1B", "model_qualifier": "30 kW Combi Boiler", "winter_efficiency_pct": 89.7, "summer_efficiency_pct": 81.1, "comparative_hot_water_efficiency_pct": 63.3, "output_kw_max": 23.7, "final_year_of_manufacture": 2012, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015980", "000033", "0", "2008/Nov/24 09:34", "Viessmann", "Viessmann", "Vitodens 100 W WB1B", "30 kW Combi Boiler", "", "2008", "2012", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "23.7", "23.7", "", "", "89.7", "81.1", "", "63.3", "", "2", "1", "", "104", "1", "2", "125", "7", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "", "0005", "", "", "", "", "", "", "", "", "90.4", "100.5", "", "", "", "", "98.6"]} +{"pcdb_id": 15981, "brand_name": "Viessmann", "model_name": "Vitodens 100 W WB1B", "model_qualifier": "35kW Combi Boiler", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 62.5, "output_kw_max": 23.7, "final_year_of_manufacture": 2012, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015981", "000033", "0", "2010/Sep/29 12:25", "Viessmann", "Viessmann", "Vitodens 100 W WB1B", "35kW Combi Boiler", "GC No 47-819-20", "2008", "2012", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "23.7", "23.7", "", "", "88.7", "80.1", "", "62.5", "", "2", "", "", "104", "1", "2", "125", "7", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "", "0005", "", "", "", "", "", "", "", "", "88.5", "98.3", "", "", "", "", "96.4"]} +{"pcdb_id": 15982, "brand_name": "Viessmann", "model_name": "Vitodens 100 W WB1B", "model_qualifier": "35kW Combi Boiler", "winter_efficiency_pct": 89.7, "summer_efficiency_pct": 81.1, "comparative_hot_water_efficiency_pct": 63.3, "output_kw_max": 23.7, "final_year_of_manufacture": 2012, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015982", "000033", "0", "2008/Nov/24 09:36", "Viessmann", "Viessmann", "Vitodens 100 W WB1B", "35kW Combi Boiler", "", "2008", "2012", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "23.7", "23.7", "", "", "89.7", "81.1", "", "63.3", "", "2", "1", "", "104", "1", "2", "125", "7", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "", "0005", "", "", "", "", "", "", "", "", "90.4", "100.5", "", "", "", "", "98.6"]} +{"pcdb_id": 15983, "brand_name": "Viessmann", "model_name": "Vitodens 100 W WB1B", "model_qualifier": "26kW System Boiler", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 78.9, "comparative_hot_water_efficiency_pct": 57.6, "output_kw_max": 23.7, "final_year_of_manufacture": 2012, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015983", "000033", "0", "2012/Aug/28 09:57", "Viessmann", "Viessmann", "Vitodens 100 W WB1B", "26kW System Boiler", "GC No 41-819-12", "2008", "2012", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "23.7", "23.7", "", "", "87.9", "78.9", "", "57.6", "", "2", "", "", "102", "1", "2", "107", "7", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.1", "96.4", "", "", "", "", "94.8"]} +{"pcdb_id": 15984, "brand_name": "Viessmann", "model_name": "Vitodens 100 W WB1B", "model_qualifier": "26kW System Boiler", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 23.7, "final_year_of_manufacture": 2012, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015984", "000033", "0", "2012/Mar/27 10:12", "Viessmann", "Viessmann", "Vitodens 100 W WB1B", "26kW System Boiler", "", "2008", "2012", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "23.7", "23.7", "", "", "88.9", "79.9", "", "58.3", "", "2", "1", "", "102", "1", "2", "107", "7", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.1", "98.5", "", "", "", "", "96.9"]} +{"pcdb_id": 15985, "brand_name": "Viessmann", "model_name": "Vitodens 100 W WB1B", "model_qualifier": "30kW System Boiler", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 27.3, "final_year_of_manufacture": 2012, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015985", "000033", "0", "2012/Aug/28 09:57", "Viessmann", "Viessmann", "Vitodens 100 W WB1B", "30kW System Boiler", "GC No. 41-819-13", "2008", "2012", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "27.3", "27.3", "", "", "88.7", "79.7", "", "58.2", "", "2", "", "", "102", "1", "2", "111", "7", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "98.4", "", "", "", "", "96.5"]} +{"pcdb_id": 15986, "brand_name": "Viessmann", "model_name": "Vitodens 100 W WB1B", "model_qualifier": "30kW System Boiler", "winter_efficiency_pct": 89.7, "summer_efficiency_pct": 80.7, "comparative_hot_water_efficiency_pct": 58.9, "output_kw_max": 27.3, "final_year_of_manufacture": 2012, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015986", "000033", "0", "2012/Mar/27 10:12", "Viessmann", "Viessmann", "Vitodens 100 W WB1B", "30kW System Boiler", "", "2008", "2012", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "27.3", "27.3", "", "", "89.7", "80.7", "", "58.9", "", "2", "1", "", "102", "1", "2", "111", "7", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.3", "100.6", "", "", "", "", "98.6"]} +{"pcdb_id": 15987, "brand_name": "Viessmann", "model_name": "Vitodens 100 W WB1B", "model_qualifier": "35kW System Boiler", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 31.9, "final_year_of_manufacture": 2012, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015987", "000033", "0", "2012/Aug/28 09:57", "Viessmann", "Viessmann", "Vitodens 100 W WB1B", "35kW System Boiler", "GC No. 41-819-14", "2008", "2012", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "31.9", "31.9", "", "", "88.8", "79.8", "", "58.3", "", "2", "", "", "102", "1", "2", "154", "7", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.6", "98.6", "", "", "", "", "96.7"]} +{"pcdb_id": 15988, "brand_name": "Viessmann", "model_name": "Vitodens 100 W WB1B", "model_qualifier": "35kW System Boiler", "winter_efficiency_pct": 89.8, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 59.0, "output_kw_max": 31.9, "final_year_of_manufacture": 2012, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015988", "000033", "0", "2012/Mar/27 10:12", "Viessmann", "Viessmann", "Vitodens 100 W WB1B", "35kW System Boiler", "", "2008", "2012", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "31.9", "31.9", "", "", "89.8", "80.8", "", "59.0", "", "2", "1", "", "102", "1", "2", "154", "7", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.5", "100.8", "", "", "", "", "98.8"]} +{"pcdb_id": 15989, "brand_name": "Viessmann", "model_name": "Vitodens 333", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 81.1, "comparative_hot_water_efficiency_pct": 54.0, "output_kw_max": 24.1, "final_year_of_manufacture": 2012, "subsidiary_type": 0, "store_type": 1, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015989", "000033", "0", "2024/Jan/31 10:17", "Viessmann", "Viessmann", "Vitodens 333", "", "GC No 47-819-07", "2007", "2012", "1", "1", "1", "2", "0", "", "", "2", "2", "2", "24.1", "24.1", "", "", "88.4", "81.1", "", "54.0", "", "2", "", "", "106", "1", "2", "65", "7", "1", "", "0", "86", "0", "50", "5", "60", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "97.8", "", "", "", "", "95.9"]} +{"pcdb_id": 15990, "brand_name": "Viessmann", "model_name": "Vitodens 333", "model_qualifier": "", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 82.1, "comparative_hot_water_efficiency_pct": 54.7, "output_kw_max": 24.1, "final_year_of_manufacture": 2012, "subsidiary_type": 0, "store_type": 1, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015990", "000033", "0", "2024/Jan/31 10:17", "Viessmann", "Viessmann", "Vitodens 333", "", "", "2007", "2012", "2", "1", "1", "2", "0", "", "", "2", "2", "2", "24.1", "24.1", "", "", "89.4", "82.1", "", "54.7", "", "2", "1", "", "106", "1", "2", "65", "7", "1", "", "0", "86", "0", "50", "5", "60", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.8", "100.0", "", "", "", "", "98.1"]} +{"pcdb_id": 15991, "brand_name": "Vaillant", "model_name": "ecoTEC VU GB 466/4-5", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 44.1, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015991", "000031", "0", "2019/Jul/31 15:29", "Vaillant", "Vaillant", "ecoTEC VU GB 466/4-5", "", "GC No. 41-044-058", "2007", "2018", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "44.1", "44.1", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "180", "4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0045", "", "", "", "", "", "", "", "", "88.7", "97.6", "", "", "", "", "95.9"]} +{"pcdb_id": 15993, "brand_name": "Vaillant", "model_name": "ecoTEC VU GB 656/4-5-H", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 63.7, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015993", "000031", "0", "2019/Jul/31 15:32", "Vaillant", "Vaillant", "ecoTEC VU GB 656/4-5-H", "", "GC no 41-044-059", "2007", "2018", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "63.7", "63.7", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "260", "4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0045", "", "", "", "", "", "", "", "", "87.8", "96.9", "", "", "", "", "95.2"]} +{"pcdb_id": 15994, "brand_name": "Halstead", "model_name": "iheat", "model_qualifier": "20", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 19.68, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015994", "000019", "0", "2012/Mar/27 10:12", "Halstead Boilers", "Halstead", "iheat", "20", "4126025", "2008", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "19.68", "19.68", "", "", "88.1", "79.1", "", "57.8", "", "2", "", "", "102", "1", "2", "150", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.7", "96.9", "", "", "", "", "95.3"]} +{"pcdb_id": 15995, "brand_name": "Halstead", "model_name": "iheat", "model_qualifier": "25c", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 56.0, "output_kw_max": 19.64, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015995", "000019", "0", "2010/Jan/28 11:55", "Halstead Boilers", "Halstead", "iheat", "25c", "4726016", "2008", "current", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "19.64", "19.64", "", "", "88.2", "79.6", "", "56.0", "", "2", "", "", "104", "1", "2", "150", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.5", "97.0", "", "", "", "", "95.4"]} +{"pcdb_id": 15996, "brand_name": "Halstead", "model_name": "iheat", "model_qualifier": "25s", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 24.53, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015996", "000019", "0", "2012/Mar/27 10:12", "Halstead Boilers", "Halstead", "iheat", "25s", "4126024", "2008", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "24.53", "24.53", "", "", "88.1", "79.1", "", "57.8", "", "2", "", "", "102", "1", "2", "150", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.4", "96.9", "", "", "", "", "95.3"]} +{"pcdb_id": 15997, "brand_name": "Halstead", "model_name": "iheat", "model_qualifier": "30c", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 55.9, "output_kw_max": 24.45, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015997", "000019", "0", "2010/Jan/28 11:55", "Halstead Boilers", "Halstead", "iheat", "30c", "4726017", "2008", "current", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "24.45", "24.45", "", "", "88.2", "79.6", "", "55.9", "", "2", "", "", "104", "1", "2", "150", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.1", "97.1", "", "", "", "", "95.4"]} +{"pcdb_id": 15998, "brand_name": "Halstead", "model_name": "iheat", "model_qualifier": "35c", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 55.9, "output_kw_max": 29.31, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015998", "000019", "0", "2010/Jan/28 11:56", "Halstead Boilers", "Halstead", "iheat", "35c", "4726018", "2008", "current", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "29.31", "29.31", "", "", "88.1", "79.5", "", "55.9", "", "2", "", "", "104", "1", "2", "150", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "97.1", "", "", "", "", "95.4"]} +{"pcdb_id": 15999, "brand_name": "Halstead", "model_name": "Iheat", "model_qualifier": "29c", "winter_efficiency_pct": 85.2, "summer_efficiency_pct": 76.6, "comparative_hot_water_efficiency_pct": 53.9, "output_kw_max": 28.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["015999", "000019", "0", "2009/Jan/20 16:27", "Halstead Boilers", "Halstead", "Iheat", "29c", "4726020", "2008", "current", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "28.30", "28.30", "", "", "85.2", "76.6", "", "53.9", "", "2", "", "", "104", "1", "2", "150", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "89.6", "", "", "", "", "89.3"]} +{"pcdb_id": 16005, "brand_name": "Dimplex", "model_name": "OV 18", "model_qualifier": "", "winter_efficiency_pct": 90.2, "summer_efficiency_pct": 81.2, "comparative_hot_water_efficiency_pct": 59.3, "output_kw_max": 18.1, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016005", "000019", "0", "2012/Mar/27 10:12", "Dimplex", "Dimplex", "OV 18", "", "", "2008", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "18.1", "18.1", "", "", "90.2", "81.2", "", "59.3", "", "2", "1", "", "102", "1", "2", "15.5", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "91.7", "101.3", "", "", "", "", "99.5"]} +{"pcdb_id": 16006, "brand_name": "Dimplex", "model_name": "OV 18", "model_qualifier": "", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 18.1, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016006", "000019", "0", "2012/Mar/27 10:12", "Dimplex", "Dimplex", "OV 18", "", "GC No. 41-149-04", "2008", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18.1", "18.1", "", "", "89.2", "80.2", "", "58.6", "", "2", "", "", "102", "1", "2", "15.5", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.7", "99.1", "", "", "", "", "97.3"]} +{"pcdb_id": 16007, "brand_name": "Dimplex", "model_name": "OV 32", "model_qualifier": "", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 80.4, "comparative_hot_water_efficiency_pct": 58.7, "output_kw_max": 30.7, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016007", "000019", "0", "2012/Mar/27 10:12", "Dimplex", "Dimplex", "OV 32", "", "", "2008", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "30.7", "30.7", "", "", "89.4", "80.4", "", "58.7", "", "2", "1", "", "102", "1", "2", "41.4", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.0", "99.8", "", "", "", "", "98.0"]} +{"pcdb_id": 16008, "brand_name": "Dimplex", "model_name": "OV 32", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 30.7, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016008", "000019", "0", "2012/Mar/27 10:12", "Dimplex", "Dimplex", "OV 32", "", "GC No. 41-149-03", "2008", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "30.7", "30.7", "", "", "88.3", "79.3", "", "58.0", "", "2", "", "", "102", "1", "2", "41.4", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "97.7", "", "", "", "", "95.8"]} +{"pcdb_id": 16009, "brand_name": "Dimplex", "model_name": "Combi 38", "model_qualifier": "", "winter_efficiency_pct": 90.0, "summer_efficiency_pct": 81.4, "comparative_hot_water_efficiency_pct": 57.2, "output_kw_max": 30.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016009", "000019", "0", "2011/Jun/14 10:11", "Dimplex", "Dimplex", "Combi 38", "", "", "2008", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "30", "30", "", "", "90.0", "81.4", "", "57.2", "", "2", "1", "", "104", "1", "2", "127", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.4", "101.3", "", "", "", "", "99.2"]} +{"pcdb_id": 16010, "brand_name": "Dimplex", "model_name": "Combi 38", "model_qualifier": "", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.4, "comparative_hot_water_efficiency_pct": 56.5, "output_kw_max": 30.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016010", "000019", "0", "2011/Jun/30 09:50", "Dimplex", "Dimplex", "Combi 38", "", "GC No. 47-149-01", "2008", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "30", "30", "", "", "89.0", "80.4", "", "56.5", "", "2", "", "", "104", "1", "2", "127", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.4", "99.1", "", "", "", "", "97.1"]} +{"pcdb_id": 16011, "brand_name": "Dimplex", "model_name": "Combi 30", "model_qualifier": "", "winter_efficiency_pct": 89.5, "summer_efficiency_pct": 80.9, "comparative_hot_water_efficiency_pct": 56.9, "output_kw_max": 23.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016011", "000019", "0", "2011/Jun/14 10:11", "Dimplex", "Dimplex", "Combi 30", "", "", "2008", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "23.3", "23.3", "", "", "89.5", "80.9", "", "56.9", "", "2", "1", "", "104", "1", "2", "121", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.9", "100.1", "", "", "", "", "98.2"]} +{"pcdb_id": 16012, "brand_name": "Dimplex", "model_name": "Combi 30", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 56.1, "output_kw_max": 23.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016012", "000019", "0", "2011/Jun/14 10:11", "Dimplex", "Dimplex", "Combi 30", "", "GC No. 47-149-02", "2008", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "23.3", "23.3", "", "", "88.4", "79.8", "", "56.1", "", "2", "", "", "104", "1", "2", "121", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "97.9", "", "", "", "", "96.0"]} +{"pcdb_id": 16013, "brand_name": "Dimplex", "model_name": "Combi 24", "model_qualifier": "", "winter_efficiency_pct": 90.2, "summer_efficiency_pct": 81.6, "comparative_hot_water_efficiency_pct": 57.4, "output_kw_max": 18.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016013", "000019", "0", "2011/Jun/14 10:11", "Dimplex", "Dimplex", "Combi 24", "", "", "2008", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "18", "18", "", "", "90.2", "81.6", "", "57.4", "", "2", "1", "", "104", "1", "2", "96", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.3", "101.9", "", "", "", "", "99.7"]} +{"pcdb_id": 16014, "brand_name": "Dimplex", "model_name": "Combi 24", "model_qualifier": "", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 80.6, "comparative_hot_water_efficiency_pct": 56.7, "output_kw_max": 18.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016014", "000019", "0", "2011/Jun/30 09:50", "Dimplex", "Dimplex", "Combi 24", "", "GC No. 47-149-03", "2008", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "18", "18", "", "", "89.2", "80.6", "", "56.7", "", "2", "", "", "104", "1", "2", "96", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "99.7", "", "", "", "", "97.5"]} +{"pcdb_id": 16015, "brand_name": "Dimplex", "model_name": "System 30", "model_qualifier": "", "winter_efficiency_pct": 90.1, "summer_efficiency_pct": 81.1, "comparative_hot_water_efficiency_pct": 59.3, "output_kw_max": 29.8, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016015", "000019", "0", "2012/Mar/27 10:12", "Dimplex", "Dimplex", "System 30", "", "", "2008", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "29.8", "29.8", "", "", "90.1", "81.1", "", "59.3", "", "2", "1", "", "102", "1", "2", "123", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.3", "101.7", "", "", "", "", "99.5"]} +{"pcdb_id": 16016, "brand_name": "Dimplex", "model_name": "System 30", "model_qualifier": "", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 29.8, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016016", "000019", "0", "2012/Mar/27 10:12", "Dimplex", "Dimplex", "System 30", "", "GC No. 41-149-01", "2008", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "29.8", "29.8", "", "", "89.1", "80.1", "", "58.5", "", "2", "", "", "102", "1", "2", "123", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "99.5", "", "", "", "", "97.3"]} +{"pcdb_id": 16017, "brand_name": "Dimplex", "model_name": "System 18", "model_qualifier": "", "winter_efficiency_pct": 90.2, "summer_efficiency_pct": 81.2, "comparative_hot_water_efficiency_pct": 59.3, "output_kw_max": 18.1, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016017", "000019", "0", "2012/Mar/27 10:12", "Dimplex", "Dimplex", "System 18", "", "", "2008", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "18.1", "18.1", "", "", "90.2", "81.2", "", "59.3", "", "2", "1", "", "102", "1", "2", "98.7", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "91.7", "101.3", "", "", "", "", "99.5"]} +{"pcdb_id": 16018, "brand_name": "Dimplex", "model_name": "System 18", "model_qualifier": "", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 18.1, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016018", "000019", "0", "2012/Mar/27 10:12", "Dimplex", "Dimplex", "System 18", "", "GC No. 41-149-02", "2008", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18.1", "18.1", "", "", "89.2", "80.2", "", "58.6", "", "2", "", "", "102", "1", "2", "98.7", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.7", "99.1", "", "", "", "", "97.3"]} +{"pcdb_id": 16019, "brand_name": "Halstead", "model_name": "Iheat", "model_qualifier": "24c", "winter_efficiency_pct": 85.4, "summer_efficiency_pct": 76.8, "comparative_hot_water_efficiency_pct": 54.0, "output_kw_max": 24.35, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016019", "000019", "0", "2009/Jan/20 16:27", "Halstead Boilers", "Halstead", "Iheat", "24c", "4726019", "2008", "current", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "24.35", "24.35", "", "", "85.4", "76.8", "", "54.0", "", "2", "", "", "104", "1", "2", "150", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "90.2", "", "", "", "", "89.7"]} +{"pcdb_id": 16020, "brand_name": "Grandee", "model_name": "GSCF 10-15", "model_qualifier": "", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 78.9, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 12.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016020", "000259", "0", "2012/Mar/27 10:12", "Grandee Boilers", "Grandee", "GSCF 10-15", "", "", "2008", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "10", "12", "", "", "86.7", "78.9", "", "57.7", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "89.3", "92.4", "", "", "", "", "91.8"]} +{"pcdb_id": 16021, "brand_name": "Grandee", "model_name": "GCF 10-15", "model_qualifier": "", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 78.9, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 12.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016021", "000259", "0", "2012/Mar/27 10:12", "Grandee Boilers", "Grandee", "GCF 10-15", "", "", "2008", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "10", "12", "", "", "86.7", "78.9", "", "57.7", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "89.3", "92.4", "", "", "", "", "91.8"]} +{"pcdb_id": 16022, "brand_name": "Grandee", "model_name": "GCCF 15/23", "model_qualifier": "", "winter_efficiency_pct": 87.4, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 56.2, "output_kw_max": 20.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016022", "000259", "0", "2009/Mar/31 13:53", "Grandee Boilers", "Grandee", "GCCF 15/23", "", "", "2008", "current", "4", "1", "1", "2", "0", "", "", "2", "3", "1", "15", "20", "", "", "87.4", "80.0", "", "56.2", "", "2", "", "", "202", "1", "1", "", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.4", "93.3", "", "", "", "", "92.8"]} +{"pcdb_id": 16024, "brand_name": "Grandee", "model_name": "GSCW 10-15", "model_qualifier": "", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 78.9, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 12.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016024", "000259", "0", "2012/Mar/27 10:12", "Grandee Boilers", "Grandee", "GSCW 10-15", "", "", "2008", "current", "4", "2", "1", "1", "0", "", "", "2", "3", "1", "10", "12", "", "", "86.7", "78.9", "", "57.7", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "89.3", "92.4", "", "", "", "", "91.8"]} +{"pcdb_id": 16025, "brand_name": "Grandee", "model_name": "GSCW 10-15 Ext", "model_qualifier": "", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 78.9, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 15.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016025", "000259", "0", "2012/Mar/27 10:12", "Grandee Boilers", "Grandee", "GSCW 10-15 Ext", "", "", "2008", "current", "4", "2", "2", "1", "0", "", "", "2", "3", "1", "10", "15", "", "", "86.7", "78.9", "", "57.7", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "89.3", "92.4", "", "", "", "", "91.8"]} +{"pcdb_id": 16026, "brand_name": "Grandee", "model_name": "GCW 10-15 Ext", "model_qualifier": "", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 78.9, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 15.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016026", "000259", "0", "2012/Mar/27 10:12", "Grandee Boilers", "Grandee", "GCW 10-15 Ext", "", "", "2008", "current", "4", "2", "2", "1", "0", "", "", "2", "3", "1", "10", "15", "", "", "86.7", "78.9", "", "57.7", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "89.3", "92.4", "", "", "", "", "91.8"]} +{"pcdb_id": 16027, "brand_name": "Grandee", "model_name": "GCW 10-15", "model_qualifier": "", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 78.9, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 12.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016027", "000259", "0", "2012/Mar/27 10:12", "Grandee Boilers", "Grandee", "GCW 10-15", "", "", "2008", "current", "4", "2", "1", "1", "0", "", "", "2", "3", "1", "10", "12", "", "", "86.7", "78.9", "", "57.7", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "89.3", "92.4", "", "", "", "", "91.8"]} +{"pcdb_id": 16030, "brand_name": "Grandee", "model_name": "GSCF 15/23", "model_qualifier": "", "winter_efficiency_pct": 87.4, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 20.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016030", "000259", "0", "2012/Mar/27 10:12", "Grandee Boilers", "Grandee", "GSCF 15/23", "", "", "2008", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "15", "20", "", "", "87.4", "79.6", "", "58.1", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.4", "93.3", "", "", "", "", "92.8"]} +{"pcdb_id": 16032, "brand_name": "Grandee", "model_name": "GCF 15/23", "model_qualifier": "", "winter_efficiency_pct": 87.4, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 20.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016032", "000259", "0", "2012/Mar/27 10:12", "Grandee Boilers", "Grandee", "GCF 15/23", "", "", "2008", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "15", "20", "", "", "87.4", "79.6", "", "58.1", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.4", "93.3", "", "", "", "", "92.8"]} +{"pcdb_id": 16034, "brand_name": "Grandee", "model_name": "GCCF 23/30", "model_qualifier": "", "winter_efficiency_pct": 87.0, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 56.0, "output_kw_max": 26.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016034", "000259", "0", "2009/Mar/31 14:00", "Grandee Boilers", "Grandee", "GCCF 23/30", "", "", "2008", "current", "4", "1", "1", "2", "0", "", "", "2", "3", "1", "23", "26", "", "", "87.0", "79.6", "", "56.0", "", "2", "", "", "202", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.1", "92.6", "", "", "", "", "92.1"]} +{"pcdb_id": 16036, "brand_name": "Grandee", "model_name": "GSCF 23/30", "model_qualifier": "", "winter_efficiency_pct": 87.0, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 26.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016036", "000259", "0", "2012/Mar/27 10:12", "Grandee Boilers", "Grandee", "GSCF 23/30", "", "", "2008", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "23", "26", "", "", "87.0", "79.2", "", "57.9", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.1", "92.6", "", "", "", "", "92.1"]} +{"pcdb_id": 16038, "brand_name": "Grandee", "model_name": "GCCW 23/28 Ext", "model_qualifier": "", "winter_efficiency_pct": 87.0, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 56.0, "output_kw_max": 26.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016038", "000259", "0", "2009/Aug/24 17:03", "Grandee Boilers", "Grandee", "GCCW 23/28 Ext", "", "", "2008", "current", "4", "2", "2", "2", "0", "", "", "2", "3", "1", "23", "26", "", "", "87.0", "79.6", "", "56.0", "", "2", "", "", "202", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.1", "92.6", "", "", "", "", "92.1"]} +{"pcdb_id": 16039, "brand_name": "Grandee", "model_name": "GCF 23/30", "model_qualifier": "", "winter_efficiency_pct": 87.0, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 26.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016039", "000259", "0", "2012/Mar/27 10:12", "Grandee Boilers", "Grandee", "GCF 23/30", "", "", "2008", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "23", "26", "", "", "87.0", "79.2", "", "57.9", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.1", "92.6", "", "", "", "", "92.1"]} +{"pcdb_id": 16040, "brand_name": "Grandee", "model_name": "GCCW 23/28", "model_qualifier": "", "winter_efficiency_pct": 87.0, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 56.0, "output_kw_max": 26.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016040", "000259", "0", "2009/Mar/31 13:59", "Grandee Boilers", "Grandee", "GCCW 23/28", "", "", "2008", "current", "4", "2", "1", "2", "0", "", "", "2", "3", "1", "23", "26", "", "", "87.0", "79.6", "", "56.0", "", "2", "", "", "202", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.1", "92.6", "", "", "", "", "92.1"]} +{"pcdb_id": 16041, "brand_name": "Grandee", "model_name": "GSCW 23/28 Ext", "model_qualifier": "", "winter_efficiency_pct": 87.0, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 26.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016041", "000259", "0", "2012/Mar/27 10:12", "Grandee Boilers", "Grandee", "GSCW 23/28 Ext", "", "", "2008", "current", "4", "2", "2", "1", "0", "", "", "2", "3", "1", "23", "26", "", "", "87.0", "79.2", "", "57.9", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.1", "92.6", "", "", "", "", "92.1"]} +{"pcdb_id": 16042, "brand_name": "Grandee", "model_name": "GCW 23/28 Ext", "model_qualifier": "", "winter_efficiency_pct": 87.0, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 26.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016042", "000259", "0", "2012/Mar/27 10:12", "Grandee Boilers", "Grandee", "GCW 23/28 Ext", "", "", "2008", "current", "4", "2", "2", "1", "0", "", "", "2", "3", "1", "23", "26", "", "", "87.0", "79.2", "", "57.9", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.1", "92.6", "", "", "", "", "92.1"]} +{"pcdb_id": 16043, "brand_name": "Grandee", "model_name": "GSCW 23/28", "model_qualifier": "", "winter_efficiency_pct": 87.0, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 26.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016043", "000259", "0", "2012/Mar/27 10:12", "Grandee Boilers", "Grandee", "GSCW 23/28", "", "", "2008", "current", "4", "2", "1", "1", "0", "", "", "2", "3", "1", "23", "26", "", "", "87.0", "79.2", "", "57.9", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.1", "92.6", "", "", "", "", "92.1"]} +{"pcdb_id": 16044, "brand_name": "Grandee", "model_name": "GCW 23/28", "model_qualifier": "", "winter_efficiency_pct": 87.0, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 26.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016044", "000259", "0", "2012/Mar/27 10:12", "Grandee Boilers", "Grandee", "GCW 23/28", "", "", "2008", "current", "4", "2", "1", "1", "0", "", "", "2", "3", "1", "23", "26", "", "", "87.0", "79.2", "", "57.9", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.1", "92.6", "", "", "", "", "92.1"]} +{"pcdb_id": 16045, "brand_name": "Grandee", "model_name": "GCW 15/22", "model_qualifier": "", "winter_efficiency_pct": 87.4, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 20.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016045", "000259", "0", "2012/Mar/27 10:12", "Grandee Boilers", "Grandee", "GCW 15/22", "", "", "2008", "current", "4", "2", "1", "1", "0", "", "", "2", "3", "1", "15", "20", "", "", "87.4", "79.6", "", "58.1", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.4", "93.3", "", "", "", "", "92.8"]} +{"pcdb_id": 16046, "brand_name": "Grandee", "model_name": "GCW 15/22 Ext", "model_qualifier": "", "winter_efficiency_pct": 87.4, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 20.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016046", "000259", "0", "2012/Mar/27 10:12", "Grandee Boilers", "Grandee", "GCW 15/22 Ext", "", "", "2008", "current", "4", "2", "2", "1", "0", "", "", "2", "3", "1", "15", "20", "", "", "87.4", "79.6", "", "58.1", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.4", "93.3", "", "", "", "", "92.8"]} +{"pcdb_id": 16047, "brand_name": "Grandee", "model_name": "GSCW 15/22 Ext", "model_qualifier": "", "winter_efficiency_pct": 87.4, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 20.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016047", "000259", "0", "2012/Mar/27 10:12", "Grandee Boilers", "Grandee", "GSCW 15/22 Ext", "", "", "2008", "current", "4", "2", "2", "1", "0", "", "", "2", "3", "1", "15", "20", "", "", "87.4", "79.6", "", "58.1", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.4", "93.3", "", "", "", "", "92.8"]} +{"pcdb_id": 16048, "brand_name": "Grandee", "model_name": "GSCW 15/22", "model_qualifier": "", "winter_efficiency_pct": 87.4, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 20.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016048", "000259", "0", "2012/Mar/27 10:12", "Grandee Boilers", "Grandee", "GSCW 15/22", "", "", "2008", "current", "4", "2", "1", "1", "0", "", "", "2", "3", "1", "15", "20", "", "", "87.4", "79.6", "", "58.1", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.4", "93.3", "", "", "", "", "92.8"]} +{"pcdb_id": 16049, "brand_name": "Grandee", "model_name": "GCCW 15/22", "model_qualifier": "", "winter_efficiency_pct": 87.4, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 56.2, "output_kw_max": 20.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016049", "000259", "0", "2009/Mar/31 13:41", "Grandee Boilers", "Grandee", "GCCW 15/22", "", "", "2008", "current", "4", "2", "1", "2", "0", "", "", "2", "3", "1", "15", "20", "", "", "87.4", "80.0", "", "56.2", "", "2", "", "", "202", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.4", "93.3", "", "", "", "", "92.8"]} +{"pcdb_id": 16050, "brand_name": "Grandee", "model_name": "GCCW 15/22 Ext", "model_qualifier": "", "winter_efficiency_pct": 87.4, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 56.2, "output_kw_max": 20.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016050", "000259", "0", "2009/Aug/24 17:02", "Grandee Boilers", "Grandee", "GCCW 15/22 Ext", "", "", "2008", "current", "4", "2", "2", "2", "0", "", "", "2", "3", "1", "15", "20", "", "", "87.4", "80.0", "", "56.2", "", "2", "", "", "202", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.4", "93.3", "", "", "", "", "92.8"]} +{"pcdb_id": 16052, "brand_name": "Halstead", "model_name": "Ace HE35", "model_qualifier": "", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 56.3, "output_kw_max": 24.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016052", "000019", "0", "2009/May/21 12:53", "Halstead Boilers", "Halstead", "Ace HE35", "", "GC No. 47-260-13", "2007", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "88.7", "80.1", "", "56.3", "", "2", "", "", "104", "1", "2", "145", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.9", "98.2", "", "", "", "", "96.4"]} +{"pcdb_id": 16053, "brand_name": "Halstead", "model_name": "Eden CBX 38", "model_qualifier": "", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.4, "comparative_hot_water_efficiency_pct": 56.5, "output_kw_max": 30.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016053", "000019", "0", "2009/May/21 12:54", "Halstead Boilers", "Halstead", "Eden CBX 38", "", "", "2008", "current", "2", "2", "1", "2", "0", "", "", "2", "3", "2", "30", "30", "", "", "89.0", "80.4", "", "56.5", "", "2", "1", "", "104", "1", "2", "148", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.3", "98.7", "", "", "", "", "97.1"]} +{"pcdb_id": 16054, "brand_name": "Halstead", "model_name": "Eden CBX 38", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 55.8, "output_kw_max": 30.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016054", "000019", "0", "2009/May/21 12:54", "Halstead Boilers", "Halstead", "Eden CBX 38", "", "GC 47-260-14", "2008", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "30", "30", "", "", "88.0", "79.4", "", "55.8", "", "2", "", "", "104", "1", "2", "148", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "96.6", "", "", "", "", "95.0"]} +{"pcdb_id": 16064, "brand_name": "Halstead", "model_name": "Pulsejet 20", "model_qualifier": "", "winter_efficiency_pct": 87.1, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 20.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016064", "000019", "0", "2012/Mar/27 10:12", "Halstead Boilers", "Halstead", "Pulsejet 20", "", "955490", "2009", "current", "1", "1", "1", "1", "0", "", "", "2", "3", "2", "20", "20", "", "", "87.1", "79.5", "", "58.1", "", "2", "", "", "101", "1", "1", "25", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "88.9", "97.7", "", "", "", "", "96.0"]} +{"pcdb_id": 16065, "brand_name": "Halstead", "model_name": "Pulsejet 20", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 58.8, "output_kw_max": 20.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016065", "000019", "0", "2012/Mar/27 10:12", "Halstead Boilers", "Halstead", "Pulsejet 20", "", "", "2009", "current", "2", "1", "1", "1", "0", "", "", "2", "3", "2", "20", "20", "", "", "88.1", "80.5", "", "58.8", "", "2", "1", "", "101", "1", "1", "25", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.7", "99.8", "", "", "", "", "98.1"]} +{"pcdb_id": 16066, "brand_name": "Halstead", "model_name": "Pulsejet 32", "model_qualifier": "", "winter_efficiency_pct": 87.0, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 33.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016066", "000019", "0", "2012/Mar/27 10:12", "Halstead Boilers", "Halstead", "Pulsejet 32", "", "955491", "2009", "current", "1", "1", "1", "1", "0", "", "", "2", "3", "2", "33.2", "33.2", "", "", "87.0", "79.4", "", "58.0", "", "2", "", "", "101", "1", "1", "25", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "88.7", "97.4", "", "", "", "", "95.8"]} +{"pcdb_id": 16067, "brand_name": "Halstead", "model_name": "Pulsejet 32", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 80.4, "comparative_hot_water_efficiency_pct": 58.7, "output_kw_max": 33.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016067", "000019", "0", "2012/Mar/27 10:12", "Halstead Boilers", "Halstead", "Pulsejet 32", "", "", "2009", "current", "2", "1", "1", "1", "0", "", "", "2", "3", "2", "33.2", "33.2", "", "", "88.0", "80.4", "", "58.7", "", "2", "1", "", "101", "1", "1", "25", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.7", "99.6", "", "", "", "", "97.9"]} +{"pcdb_id": 16068, "brand_name": "Halstead", "model_name": "Pulsejet 40", "model_qualifier": "", "winter_efficiency_pct": 87.0, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 40.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016068", "000019", "0", "2012/Mar/27 10:12", "Halstead Boilers", "Halstead", "Pulsejet 40", "", "955492", "2009", "current", "1", "1", "1", "1", "0", "", "", "2", "3", "2", "40", "40", "", "", "87.0", "79.4", "", "58.0", "", "2", "", "", "101", "1", "1", "25", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "88.7", "97.5", "", "", "", "", "95.8"]} +{"pcdb_id": 16069, "brand_name": "Halstead", "model_name": "Pulsejet 40", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 80.4, "comparative_hot_water_efficiency_pct": 58.7, "output_kw_max": 40.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016069", "000019", "0", "2012/Mar/27 10:12", "Halstead Boilers", "Halstead", "Pulsejet 40", "", "", "2009", "current", "2", "1", "1", "1", "0", "", "", "2", "3", "2", "40", "40", "", "", "88.0", "80.4", "", "58.7", "", "2", "1", "", "101", "1", "1", "25", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.7", "99.7", "", "", "", "", "98.0"]} +{"pcdb_id": 16070, "brand_name": "Fondital", "model_name": "Tahiti Dual HC 32 Line", "model_qualifier": "", "winter_efficiency_pct": 86.1, "summer_efficiency_pct": 77.5, "comparative_hot_water_efficiency_pct": 54.5, "output_kw_max": 30.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016070", "000250", "0", "2009/Apr/24 09:31", "Fondital", "Fondital", "Tahiti Dual HC 32 Line", "", "", "2009", "current", "2", "2", "1", "2", "0", "", "", "2", "3", "2", "30.3", "30.3", "", "", "86.1", "77.5", "", "54.5", "", "2", "1", "", "104", "1", "2", "177", "10", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.5", "92.1", "", "", "", "", "91.4"]} +{"pcdb_id": 16071, "brand_name": "Fondital", "model_name": "Tahiti Dual HR 32 Line", "model_qualifier": "", "winter_efficiency_pct": 86.1, "summer_efficiency_pct": 77.1, "comparative_hot_water_efficiency_pct": 56.3, "output_kw_max": 30.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016071", "000250", "0", "2012/Mar/27 10:12", "Fondital", "Fondital", "Tahiti Dual HR 32 Line", "", "", "2009", "current", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "30.3", "30.3", "", "", "86.1", "77.1", "", "56.3", "", "2", "1", "", "102", "1", "2", "177", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.5", "92.1", "", "", "", "", "91.4"]} +{"pcdb_id": 16072, "brand_name": "Fondital", "model_name": "Tahiti Dual HRB 32 Line", "model_qualifier": "", "winter_efficiency_pct": 86.1, "summer_efficiency_pct": 77.1, "comparative_hot_water_efficiency_pct": 56.3, "output_kw_max": 30.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016072", "000250", "0", "2012/Mar/27 10:12", "Fondital", "Fondital", "Tahiti Dual HRB 32 Line", "", "", "2009", "current", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "30.3", "30.3", "", "", "86.1", "77.1", "", "56.3", "", "2", "1", "", "102", "1", "2", "177", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.5", "92.1", "", "", "", "", "91.4"]} +{"pcdb_id": 16073, "brand_name": "Fondital", "model_name": "Tahiti Dual HC 32 Line", "model_qualifier": "", "winter_efficiency_pct": 85.1, "summer_efficiency_pct": 76.5, "comparative_hot_water_efficiency_pct": 53.8, "output_kw_max": 30.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016073", "000250", "0", "2009/Apr/24 09:32", "Fondital", "Fondital", "Tahiti Dual HC 32 Line", "", "", "2009", "current", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "30.3", "30.3", "", "", "85.1", "76.5", "", "53.8", "", "2", "", "", "104", "1", "2", "177", "10", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "86.6", "90.1", "", "", "", "", "89.4"]} +{"pcdb_id": 16074, "brand_name": "Fondital", "model_name": "Tahiti Dual HR 32 Line", "model_qualifier": "", "winter_efficiency_pct": 85.1, "summer_efficiency_pct": 76.1, "comparative_hot_water_efficiency_pct": 55.6, "output_kw_max": 30.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016074", "000250", "0", "2012/Mar/27 10:12", "Fondital", "Fondital", "Tahiti Dual HR 32 Line", "", "", "2009", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "30.3", "30.3", "", "", "85.1", "76.1", "", "55.6", "", "2", "", "", "102", "1", "2", "177", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "86.6", "90.1", "", "", "", "", "89.4"]} +{"pcdb_id": 16075, "brand_name": "Fondital", "model_name": "Tahiti Dual HRB 32 Line", "model_qualifier": "", "winter_efficiency_pct": 85.1, "summer_efficiency_pct": 76.1, "comparative_hot_water_efficiency_pct": 55.6, "output_kw_max": 30.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016075", "000250", "0", "2012/Mar/27 10:12", "Fondital", "Fondital", "Tahiti Dual HRB 32 Line", "", "", "2009", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "30.3", "30.3", "", "", "85.1", "76.1", "", "55.6", "", "2", "", "", "102", "1", "2", "177", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "86.6", "90.1", "", "", "", "", "89.4"]} +{"pcdb_id": 16080, "brand_name": "Ferroli", "model_name": "Optimax HE Plus", "model_qualifier": "18 S", "winter_efficiency_pct": 89.7, "summer_efficiency_pct": 80.7, "comparative_hot_water_efficiency_pct": 58.9, "output_kw_max": 17.7, "final_year_of_manufacture": 2017, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016080", "000097", "0", "2017/Aug/21 13:41", "Ferroli", "Ferroli", "Optimax HE Plus", "18 S", "", "2009", "2017", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "17.7", "17.7", "", "", "89.7", "80.7", "", "58.9", "", "2", "1", "", "102", "1", "2", "115", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.5", "100.5", "", "", "", "", "98.6"]} +{"pcdb_id": 16081, "brand_name": "Ferroli", "model_name": "Optimax HE Plus", "model_qualifier": "18 OV", "winter_efficiency_pct": 89.7, "summer_efficiency_pct": 80.7, "comparative_hot_water_efficiency_pct": 58.9, "output_kw_max": 17.7, "final_year_of_manufacture": 2017, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016081", "000097", "0", "2017/Aug/21 13:44", "Ferroli", "Ferroli", "Optimax HE Plus", "18 OV", "", "2009", "2017", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "17.7", "17.7", "", "", "89.7", "80.7", "", "58.9", "", "2", "1", "", "102", "1", "2", "50", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.5", "100.5", "", "", "", "", "98.6"]} +{"pcdb_id": 16082, "brand_name": "Ferroli", "model_name": "Optimax HE Plus", "model_qualifier": "25 OV", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 80.4, "comparative_hot_water_efficiency_pct": 58.7, "output_kw_max": 24.6, "final_year_of_manufacture": 2017, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016082", "000097", "0", "2017/Aug/21 13:44", "Ferroli", "Ferroli", "Optimax HE Plus", "25 OV", "", "2009", "2017", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "24.6", "24.6", "", "", "89.4", "80.4", "", "58.7", "", "2", "1", "", "102", "1", "2", "50", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.5", "99.7", "", "", "", "", "98.0"]} +{"pcdb_id": 16083, "brand_name": "Ferroli", "model_name": "Optimax HE Plus", "model_qualifier": "25 S", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 80.4, "comparative_hot_water_efficiency_pct": 58.7, "output_kw_max": 24.6, "final_year_of_manufacture": 2017, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016083", "000097", "0", "2017/Aug/21 13:45", "Ferroli", "Ferroli", "Optimax HE Plus", "25 S", "", "2009", "2017", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "24.6", "24.6", "", "", "89.4", "80.4", "", "58.7", "", "2", "1", "", "102", "1", "2", "115", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.5", "99.7", "", "", "", "", "98.0"]} +{"pcdb_id": 16084, "brand_name": "Ferroli", "model_name": "Optimax HE Plus", "model_qualifier": "31 C", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 56.8, "output_kw_max": 24.6, "final_year_of_manufacture": 2017, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016084", "000097", "0", "2017/Aug/21 13:45", "Ferroli", "Ferroli", "Optimax HE Plus", "31 C", "", "2009", "2017", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24.6", "24.6", "", "", "89.4", "80.8", "", "56.8", "", "2", "1", "", "104", "1", "2", "130", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "0", "", "0005", "", "", "", "", "", "", "", "", "90.5", "99.7", "", "", "", "", "98.0"]} +{"pcdb_id": 16085, "brand_name": "Ferroli", "model_name": "Optimax HE Plus", "model_qualifier": "35 S", "winter_efficiency_pct": 89.7, "summer_efficiency_pct": 80.7, "comparative_hot_water_efficiency_pct": 59.0, "output_kw_max": 30.2, "final_year_of_manufacture": 2017, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016085", "000097", "0", "2017/Aug/21 13:46", "Ferroli", "Ferroli", "Optimax HE Plus", "35 S", "", "2009", "2017", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "30.2", "30.2", "", "", "89.7", "80.7", "", "59.0", "", "2", "1", "", "102", "1", "2", "125", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.7", "100.5", "", "", "", "", "98.6"]} +{"pcdb_id": 16086, "brand_name": "Ferroli", "model_name": "Optimax HE Plus", "model_qualifier": "38 C", "winter_efficiency_pct": 89.7, "summer_efficiency_pct": 81.1, "comparative_hot_water_efficiency_pct": 57.1, "output_kw_max": 30.2, "final_year_of_manufacture": 2017, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016086", "000097", "0", "2017/Aug/21 13:39", "Ferroli", "Ferroli", "Optimax HE Plus", "38 C", "", "2009", "2017", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "30.2", "30.2", "", "", "89.7", "81.1", "", "57.1", "", "2", "1", "", "104", "1", "2", "140", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "0", "", "0005", "", "", "", "", "", "", "", "", "90.7", "100.5", "", "", "", "", "98.6"]} +{"pcdb_id": 16087, "brand_name": "Ferroli", "model_name": "Optimax HE Plus", "model_qualifier": "18 S", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 17.7, "final_year_of_manufacture": 2017, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016087", "000097", "0", "2017/Aug/07 16:54", "Ferroli", "Ferroli", "Optimax HE Plus", "18 S", "41-267-31", "2009", "2017", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "17.7", "17.7", "", "", "88.7", "79.7", "", "58.2", "", "2", "", "", "102", "1", "2", "115", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.6", "98.3", "", "", "", "", "96.5"]} +{"pcdb_id": 16089, "brand_name": "Ferroli", "model_name": "Optimax HE Plus", "model_qualifier": "18 OV", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 17.7, "final_year_of_manufacture": 2017, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016089", "000097", "0", "2017/Aug/07 17:01", "Ferroli", "Ferroli", "Optimax HE Plus", "18 OV", "41-267-29", "2009", "2017", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "17.7", "17.7", "", "", "88.7", "79.7", "", "58.2", "", "2", "", "", "102", "1", "2", "50", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.6", "98.3", "", "", "", "", "96.5"]} +{"pcdb_id": 16090, "brand_name": "Ferroli", "model_name": "Optimax HE Plus", "model_qualifier": "25 OV", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 24.6, "final_year_of_manufacture": 2017, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016090", "000097", "0", "2017/Aug/07 16:53", "Ferroli", "Ferroli", "Optimax HE Plus", "25 OV", "41-267-30", "2009", "2017", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24.6", "24.6", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "50", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.6", "97.6", "", "", "", "", "95.9"]} +{"pcdb_id": 16092, "brand_name": "Ferroli", "model_name": "Optimax HE Plus", "model_qualifier": "25 S", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 24.6, "final_year_of_manufacture": 2017, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016092", "000097", "0", "2017/Aug/07 16:59", "Ferroli", "Ferroli", "Optimax HE Plus", "25 S", "41-267-32", "2009", "2017", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24.6", "24.6", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "115", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.6", "97.6", "", "", "", "", "95.9"]} +{"pcdb_id": 16093, "brand_name": "Ferroli", "model_name": "Optimax HE Plus", "model_qualifier": "31 C", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 56.1, "output_kw_max": 24.6, "final_year_of_manufacture": 2017, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016093", "000097", "0", "2017/Aug/07 17:06", "Ferroli", "Ferroli", "Optimax HE Plus", "31 C", "47-267-44", "2009", "2017", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.6", "24.6", "", "", "88.4", "79.8", "", "56.1", "", "2", "", "", "104", "1", "2", "130", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "0", "", "0005", "", "", "", "", "", "", "", "", "88.6", "97.6", "", "", "", "", "95.9"]} +{"pcdb_id": 16094, "brand_name": "Ferroli", "model_name": "Optimax HE Plus", "model_qualifier": "35 S", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 30.2, "final_year_of_manufacture": 2017, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016094", "000097", "0", "2017/Aug/21 13:34", "Ferroli", "Ferroli", "Optimax HE Plus", "35 S", "41-267-33", "2009", "2017", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "30.2", "30.2", "", "", "88.7", "79.7", "", "58.2", "", "2", "", "", "102", "1", "2", "125", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.7", "98.3", "", "", "", "", "96.5"]} +{"pcdb_id": 16095, "brand_name": "Ferroli", "model_name": "Optimax HE Plus", "model_qualifier": "38 C", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 56.3, "output_kw_max": 30.2, "final_year_of_manufacture": 2017, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016095", "000097", "0", "2017/Aug/21 13:34", "Ferroli", "Ferroli", "Optimax HE Plus", "38 C", "47-267-45", "2009", "2017", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "30.2", "30.2", "", "", "88.7", "80.1", "", "56.3", "", "2", "", "", "104", "1", "2", "140", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "0", "", "0005", "", "", "", "", "", "", "", "", "88.7", "98.3", "", "", "", "", "96.5"]} +{"pcdb_id": 16096, "brand_name": "Vokera", "model_name": "Mynute", "model_qualifier": "24M", "winter_efficiency_pct": 81.1, "summer_efficiency_pct": 70.4, "comparative_hot_water_efficiency_pct": 51.4, "output_kw_max": 24.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016096", "000011", "0", "2012/Mar/27 10:12", "Vokera", "Vokera", "Mynute", "24M", "4109441", "2005", "current", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "24", "24", "", "", "81.1", "70.4", "", "51.4", "", "2", "", "", "102", "1", "2", "150", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0004", "", "", "", "", "", "", "", "", "82.6", "81.6", "", "", "", "", "81.8"]} +{"pcdb_id": 16097, "brand_name": "Firebird", "model_name": "Silverpac", "model_qualifier": "CR20", "winter_efficiency_pct": 87.7, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 20.0, "final_year_of_manufacture": 2010, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016097", "000047", "0", "2012/Mar/27 10:12", "Firebird Boilers", "Firebird", "Silverpac", "CR20", "", "2008", "2010", "4", "1", "2", "1", "0", "", "", "2", "1", "1", "15", "20", "", "", "87.7", "79.9", "", "58.3", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.6", "93.6", "", "", "", "", "93.2"]} +{"pcdb_id": 16098, "brand_name": "Firebird", "model_name": "Silverpac", "model_qualifier": "CR26", "winter_efficiency_pct": 87.4, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 26.0, "final_year_of_manufacture": 2010, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016098", "000047", "0", "2012/Mar/27 10:12", "Firebird Boilers", "Firebird", "Silverpac", "CR26", "", "2008", "2010", "4", "1", "2", "1", "0", "", "", "2", "1", "1", "15", "26", "", "", "87.4", "79.6", "", "58.1", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.8", "92.8", "", "", "", "", "92.6"]} +{"pcdb_id": 16099, "brand_name": "Firebird", "model_name": "Silverpac", "model_qualifier": "CR35", "winter_efficiency_pct": 86.2, "summer_efficiency_pct": 78.4, "comparative_hot_water_efficiency_pct": 57.3, "output_kw_max": 35.0, "final_year_of_manufacture": 2010, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016099", "000047", "0", "2012/Mar/27 10:12", "Firebird Boilers", "Firebird", "Silverpac", "CR35", "", "2008", "2010", "4", "1", "2", "1", "0", "", "", "2", "1", "1", "26", "35", "", "", "86.2", "78.4", "", "57.3", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "89.3", "91.1", "", "", "", "", "90.7"]} +{"pcdb_id": 16100, "brand_name": "Firebird", "model_name": "Silver Utility", "model_qualifier": "CR20", "winter_efficiency_pct": 87.7, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 20.0, "final_year_of_manufacture": 2010, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016100", "000047", "0", "2012/Mar/27 10:12", "Firebird Boilers", "Firebird", "Silver Utility", "CR20", "", "2008", "2010", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "15", "20", "", "", "87.7", "79.9", "", "58.3", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.6", "93.6", "", "", "", "", "93.2"]} +{"pcdb_id": 16101, "brand_name": "Firebird", "model_name": "Silver Utility", "model_qualifier": "CR26", "winter_efficiency_pct": 87.4, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 26.0, "final_year_of_manufacture": 2010, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016101", "000047", "0", "2012/Mar/27 10:12", "Firebird Boilers", "Firebird", "Silver Utility", "CR26", "", "2008", "2010", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "15", "26", "", "", "87.4", "79.6", "", "58.1", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.8", "92.8", "", "", "", "", "92.6"]} +{"pcdb_id": 16102, "brand_name": "Firebird", "model_name": "Silver Utility", "model_qualifier": "CR35", "winter_efficiency_pct": 86.2, "summer_efficiency_pct": 78.4, "comparative_hot_water_efficiency_pct": 57.3, "output_kw_max": 35.0, "final_year_of_manufacture": 2010, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016102", "000047", "0", "2012/Mar/27 10:12", "Firebird Boilers", "Firebird", "Silver Utility", "CR35", "", "2008", "2010", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "26", "35", "", "", "86.2", "78.4", "", "57.3", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "89.3", "91.1", "", "", "", "", "90.7"]} +{"pcdb_id": 16103, "brand_name": "Firebird", "model_name": "Silver Boilerhouse", "model_qualifier": "CR20", "winter_efficiency_pct": 87.7, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 20.0, "final_year_of_manufacture": 2010, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016103", "000047", "0", "2012/Mar/27 10:12", "Firebird Boilers", "Firebird", "Silver Boilerhouse", "CR20", "", "2008", "2010", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "15", "20", "", "", "87.7", "79.9", "", "58.3", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.6", "93.6", "", "", "", "", "93.2"]} +{"pcdb_id": 16104, "brand_name": "Firebird", "model_name": "Silver Boilerhouse", "model_qualifier": "CR26", "winter_efficiency_pct": 87.4, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 26.0, "final_year_of_manufacture": 2010, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016104", "000047", "0", "2012/Mar/27 10:12", "Firebird Boilers", "Firebird", "Silver Boilerhouse", "CR26", "", "2008", "2010", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "15", "26", "", "", "87.4", "79.6", "", "58.1", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.8", "92.8", "", "", "", "", "92.6"]} +{"pcdb_id": 16105, "brand_name": "Firebird", "model_name": "Silver Boilerhouse", "model_qualifier": "CR35", "winter_efficiency_pct": 86.2, "summer_efficiency_pct": 78.4, "comparative_hot_water_efficiency_pct": 57.3, "output_kw_max": 35.0, "final_year_of_manufacture": 2010, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016105", "000047", "0", "2012/Mar/27 10:12", "Firebird Boilers", "Firebird", "Silver Boilerhouse", "CR35", "", "2008", "2010", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "26", "35", "", "", "86.2", "78.4", "", "57.3", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "89.3", "91.1", "", "", "", "", "90.7"]} +{"pcdb_id": 16106, "brand_name": "GEM", "model_name": "CKUT1 15/20", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 20.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016106", "000260", "0", "2012/Mar/27 10:12", "GEM", "GEM", "CKUT1 15/20", "", "", "2007", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "15", "20", "", "", "88.0", "80.2", "", "58.6", "", "2", "", "", "201", "1", "1", "230", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.8", "94.8", "", "", "", "", "94.1"]} +{"pcdb_id": 16107, "brand_name": "GEM", "model_name": "CKUT2 20/26", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 26.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016107", "000260", "0", "2012/Mar/27 10:12", "GEM Heating Products", "GEM", "CKUT2 20/26", "", "", "2007", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "20", "26", "", "", "88.0", "80.2", "", "58.6", "", "2", "", "", "201", "1", "1", "230", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.8", "94.8", "", "", "", "", "94.1"]} +{"pcdb_id": 16108, "brand_name": "GEM", "model_name": "CKUT3 26/35", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 58.7, "output_kw_max": 35.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016108", "000260", "0", "2012/Mar/27 10:12", "GEM Heating Products", "GEM", "CKUT3 26/35", "", "", "2007", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "26", "35", "", "", "88.1", "80.3", "", "58.7", "", "2", "", "", "201", "1", "1", "230", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.7", "95.2", "", "", "", "", "94.3"]} +{"pcdb_id": 16109, "brand_name": "GEM", "model_name": "CKUT4 35/41", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 58.7, "output_kw_max": 40.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016109", "000260", "0", "2012/Mar/27 10:12", "GEM Heating Products", "GEM", "CKUT4 35/41", "", "", "2007", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "35", "40", "", "", "88.1", "80.3", "", "58.7", "", "2", "", "", "201", "1", "1", "230", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.7", "95.2", "", "", "", "", "94.3"]} +{"pcdb_id": 16110, "brand_name": "GEM", "model_name": "CC1 15/20", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 81.9, "comparative_hot_water_efficiency_pct": 50.3, "output_kw_max": 20.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016110", "000260", "0", "2024/Jan/31 10:17", "GEM Heating Products", "GEM", "CC1 15/20", "", "", "2007", "current", "4", "1", "1", "2", "0", "", "", "2", "3", "2", "15", "20.5", "", "", "88.0", "81.9", "", "50.3", "", "2", "", "", "203", "1", "1", "230", "", "2", "1", "0", "35", "0", "25", "3", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.8", "94.8", "", "", "", "", "94.1"]} +{"pcdb_id": 16111, "brand_name": "GEM", "model_name": "CC2 20/26", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 81.9, "comparative_hot_water_efficiency_pct": 50.3, "output_kw_max": 26.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016111", "000260", "0", "2024/Jan/31 10:17", "GEM Heating Products", "GEM", "CC2 20/26", "", "", "2007", "current", "4", "1", "1", "2", "0", "", "", "2", "3", "2", "20", "26", "", "", "88.0", "81.9", "", "50.3", "", "2", "", "", "203", "1", "1", "230", "", "2", "1", "0", "35", "0", "25", "3", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.8", "94.8", "", "", "", "", "94.1"]} +{"pcdb_id": 16112, "brand_name": "GEM", "model_name": "CC3 26/35", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 82.0, "comparative_hot_water_efficiency_pct": 50.4, "output_kw_max": 35.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016112", "000260", "0", "2024/Jan/31 10:17", "GEM Heating Products", "GEM", "CC3 26/35", "", "", "2007", "current", "4", "1", "1", "2", "0", "", "", "2", "3", "2", "26", "35", "", "", "88.1", "82.0", "", "50.4", "", "2", "", "", "203", "1", "1", "", "", "2", "1", "0", "35", "0", "25", "3", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.7", "95.2", "", "", "", "", "94.3"]} +{"pcdb_id": 16113, "brand_name": "GEM", "model_name": "CC4 35/41", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 82.0, "comparative_hot_water_efficiency_pct": 50.4, "output_kw_max": 40.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016113", "000260", "0", "2024/Jan/31 10:17", "GEM Heating Products", "GEM", "CC4 35/41", "", "", "2007", "current", "4", "1", "2", "2", "0", "", "", "2", "3", "2", "35", "40", "", "", "88.1", "82.0", "", "50.4", "", "2", "", "", "203", "1", "1", "230", "", "2", "1", "0", "35", "0", "25", "3", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.7", "95.2", "", "", "", "", "94.3"]} +{"pcdb_id": 16114, "brand_name": "GEM", "model_name": "CS1 15/20", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 20.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016114", "000260", "0", "2012/Mar/27 10:12", "GEM Heating Products", "GEM", "CS1 15/20", "", "", "2007", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "15", "20.5", "", "", "88.0", "80.2", "", "58.6", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.8", "94.8", "", "", "", "", "94.1"]} +{"pcdb_id": 16115, "brand_name": "GEM", "model_name": "CS2 20/26", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 26.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016115", "000260", "0", "2012/Mar/27 10:12", "GEM Heating Products", "GEM", "CS2 20/26", "", "", "2007", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "20.5", "26.4", "", "", "88.0", "80.2", "", "58.6", "", "2", "", "", "201", "1", "1", "230", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.8", "94.8", "", "", "", "", "94.1"]} +{"pcdb_id": 16116, "brand_name": "GEM", "model_name": "CS3 26/35", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 58.7, "output_kw_max": 35.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016116", "000260", "0", "2012/Mar/27 10:12", "GEM Heating Products", "GEM", "CS3 26/35", "", "", "2007", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "26", "35", "", "", "88.1", "80.3", "", "58.7", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.7", "95.2", "", "", "", "", "94.3"]} +{"pcdb_id": 16117, "brand_name": "GEM", "model_name": "CS4 35/41", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 58.7, "output_kw_max": 40.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016117", "000260", "0", "2012/Mar/27 10:12", "GEM Heating Products", "GEM", "CS4 35/41", "", "", "2007", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "35", "40", "", "", "88.1", "80.3", "", "58.7", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.7", "95.2", "", "", "", "", "94.3"]} +{"pcdb_id": 16118, "brand_name": "GEM", "model_name": "COD1 15/20", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 20.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016118", "000260", "0", "2012/Mar/27 10:12", "GEM Heating Products", "GEM", "COD1 15/20", "", "", "2007", "current", "4", "1", "2", "1", "0", "", "", "2", "3", "2", "15", "20", "", "", "88.0", "80.2", "", "58.6", "", "2", "", "", "201", "1", "1", "230", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.8", "94.8", "", "", "", "", "94.1"]} +{"pcdb_id": 16119, "brand_name": "GEM", "model_name": "COD C1 15/20", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 81.9, "comparative_hot_water_efficiency_pct": 50.3, "output_kw_max": 20.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016119", "000260", "0", "2024/Jan/31 10:17", "GEM Heating Products", "GEM", "COD C1 15/20", "", "", "2007", "current", "4", "1", "2", "2", "0", "", "", "2", "3", "2", "15", "20", "", "", "88.0", "81.9", "", "50.3", "", "2", "", "", "203", "1", "1", "230", "", "2", "1", "0", "35", "0", "25", "3", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "0", "", "0003", "", "", "", "", "", "", "", "", "90.8", "94.8", "", "", "", "", "94.1"]} +{"pcdb_id": 16120, "brand_name": "GEM", "model_name": "COD1 SS 15/20", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 20.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016120", "000260", "0", "2012/Mar/27 10:12", "GEM Heating Products", "GEM", "COD1 SS 15/20", "", "", "2007", "current", "4", "1", "2", "1", "0", "", "", "2", "3", "2", "15", "20", "", "", "88.0", "80.2", "", "58.6", "", "2", "", "", "201", "1", "1", "230", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.8", "94.8", "", "", "", "", "94.1"]} +{"pcdb_id": 16121, "brand_name": "GEM", "model_name": "COD2 20/26", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 26.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016121", "000260", "0", "2012/Mar/27 10:12", "GEM Heating Products", "GEM", "COD2 20/26", "", "", "2007", "current", "4", "1", "2", "1", "0", "", "", "2", "3", "2", "20", "26", "", "", "88.0", "80.2", "", "58.6", "", "2", "", "", "201", "1", "1", "230", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.8", "94.8", "", "", "", "", "94.1"]} +{"pcdb_id": 16122, "brand_name": "GEM", "model_name": "COD C2 20/26", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 81.9, "comparative_hot_water_efficiency_pct": 50.3, "output_kw_max": 26.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016122", "000260", "0", "2024/Jan/31 10:17", "GEM Heating Products", "GEM", "COD C2 20/26", "", "", "2007", "current", "4", "1", "2", "2", "0", "", "", "2", "3", "2", "20", "26", "", "", "88.0", "81.9", "", "50.3", "", "2", "", "", "203", "1", "1", "230", "", "2", "1", "0", "35", "0", "25", "3", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.8", "94.8", "", "", "", "", "94.1"]} +{"pcdb_id": 16123, "brand_name": "GEM", "model_name": "COD2 SS 20/26", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 26.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016123", "000260", "0", "2012/Mar/27 10:12", "GEM Heating Products", "GEM", "COD2 SS 20/26", "", "", "2007", "current", "4", "1", "2", "1", "0", "", "", "2", "3", "2", "20.5", "26.4", "", "", "88.0", "80.2", "", "58.6", "", "2", "", "", "201", "1", "1", "230", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.8", "94.8", "", "", "", "", "94.1"]} +{"pcdb_id": 16124, "brand_name": "GEM", "model_name": "COD3 26/35", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 58.7, "output_kw_max": 35.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016124", "000260", "0", "2012/Mar/27 10:12", "GEM Heating Products", "GEM", "COD3 26/35", "", "", "2007", "current", "4", "1", "2", "1", "0", "", "", "2", "3", "2", "26", "35", "", "", "88.1", "80.3", "", "58.7", "", "2", "", "", "201", "1", "1", "230", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.7", "95.2", "", "", "", "", "94.3"]} +{"pcdb_id": 16125, "brand_name": "GEM", "model_name": "COD C3 26/35", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 82.0, "comparative_hot_water_efficiency_pct": 50.4, "output_kw_max": 35.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016125", "000260", "0", "2024/Jan/31 10:17", "GEM Heating Products", "GEM", "COD C3 26/35", "", "", "2007", "current", "4", "1", "2", "2", "0", "", "", "2", "3", "2", "26", "35", "", "", "88.1", "82.0", "", "50.4", "", "2", "", "", "203", "1", "1", "230", "", "2", "1", "0", "35", "0", "25", "3", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.7", "95.2", "", "", "", "", "94.3"]} +{"pcdb_id": 16126, "brand_name": "GEM", "model_name": "COD3 SS 26/35", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 58.7, "output_kw_max": 35.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016126", "000260", "0", "2012/Mar/27 10:12", "GEM Heating Products", "GEM", "COD3 SS 26/35", "", "", "2007", "current", "4", "1", "2", "1", "0", "", "", "2", "3", "2", "26", "35", "", "", "88.1", "80.3", "", "58.7", "", "2", "", "", "201", "1", "1", "230", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.7", "95.2", "", "", "", "", "94.3"]} +{"pcdb_id": 16127, "brand_name": "GEM", "model_name": "COD4 35/41", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 58.7, "output_kw_max": 40.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016127", "000260", "0", "2012/Mar/27 10:12", "GEM Heating Products", "GEM", "COD4 35/41", "", "", "2007", "current", "4", "1", "2", "1", "0", "", "", "2", "3", "2", "35", "40", "", "", "88.1", "80.3", "", "58.7", "", "2", "", "", "201", "1", "1", "230", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.7", "95.2", "", "", "", "", "94.3"]} +{"pcdb_id": 16128, "brand_name": "GEM", "model_name": "COD C4 35/41", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 82.0, "comparative_hot_water_efficiency_pct": 50.4, "output_kw_max": 40.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016128", "000260", "0", "2024/Jan/31 10:17", "GEM Heating Products", "GEM", "COD C4 35/41", "", "", "2007", "current", "4", "1", "2", "2", "0", "", "", "2", "3", "2", "35", "40", "", "", "88.1", "82.0", "", "50.4", "", "2", "", "", "203", "1", "1", "230", "", "2", "1", "0", "35", "0", "25", "3", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.7", "95.2", "", "", "", "", "94.3"]} +{"pcdb_id": 16129, "brand_name": "GEM", "model_name": "COD4 SS 35/41", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 58.7, "output_kw_max": 40.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016129", "000260", "0", "2012/Mar/27 10:12", "GEM Heating Products", "GEM", "COD4 SS 35/41", "", "", "2007", "current", "4", "1", "2", "1", "0", "", "", "2", "3", "1", "35", "40", "", "", "88.1", "80.3", "", "58.7", "", "2", "", "", "201", "1", "1", "230", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.7", "95.2", "", "", "", "", "94.3"]} +{"pcdb_id": 16130, "brand_name": "Warmflow", "model_name": "Boilerhouse", "model_qualifier": "B70HE", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 21.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016130", "000063", "0", "2013/Mar/28 08:29", "Warmflow Engineering", "Warmflow", "Boilerhouse", "B70HE", "", "2009", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "15", "21", "", "", "87.9", "80.1", "", "58.5", "", "2", "", "", "201", "1", "1", "160", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "89.9", "95.0", "", "", "", "", "94.0"]} +{"pcdb_id": 16132, "brand_name": "Warmflow", "model_name": "Boilerhouse", "model_qualifier": "B90HE", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 26.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016132", "000063", "0", "2013/Mar/28 08:29", "Warmflow Engineering", "Warmflow", "Boilerhouse", "B90HE", "", "2009", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "21", "26", "", "", "87.9", "80.1", "", "58.5", "", "2", "", "", "201", "1", "1", "160", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.3", "94.8", "", "", "", "", "94.0"]} +{"pcdb_id": 16133, "brand_name": "Warmflow", "model_name": "Boilerhouse", "model_qualifier": "B120HE", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 33.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016133", "000063", "0", "2013/Mar/28 08:30", "Warmflow Engineering", "Warmflow", "Boilerhouse", "B120HE", "", "2009", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "26", "33", "", "", "88.0", "80.2", "", "58.6", "", "2", "", "", "201", "1", "1", "160", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.7", "94.7", "", "", "", "", "94.0"]} +{"pcdb_id": 16134, "brand_name": "Ariston", "model_name": "Clas HE 38", "model_qualifier": "", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 55.8, "output_kw_max": 30.3, "final_year_of_manufacture": 2013, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016134", "000080", "0", "2014/Apr/15 15:00", "Merloni TermoSanitari", "Ariston", "Clas HE 38", "", "47-116-53", "2007", "2013", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "30.3", "30.3", "", "", "87.9", "79.3", "", "55.8", "", "2", "", "", "104", "1", "2", "120", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "96.6", "", "", "", "", "94.9"]} +{"pcdb_id": 16135, "brand_name": "Intergas", "model_name": "Combi Compact HRE 28/24", "model_qualifier": "", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 86.7, "comparative_hot_water_efficiency_pct": 72.3, "output_kw_max": 23.1, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0094, "loss_factor_f1_kwh_per_day": 1.1037, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016135", "000256", "0", "2014/Dec/01 15:18", "Intergas Heating Ltd", "Intergas", "Combi Compact HRE 28/24", "", "", "2009", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "23.1", "23.1", "", "", "88.2", "86.7", "", "72.3", "", "2", "", "", "104", "1", "2", "130", "1.9", "0", "", "", "", "0", "", "", "", "", "1", "7.281", "0.138", "0.0094", "1.1037", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "97.2", "", "", "", "", "95.5"]} +{"pcdb_id": 16136, "brand_name": "Ideal", "model_name": "Logic combi", "model_qualifier": "24", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 69.3, "output_kw_max": 24.2, "final_year_of_manufacture": 2016, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.008, "loss_factor_f1_kwh_per_day": 1.46665, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016136", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "Logic combi", "24", "47-348-56", "2009", "2016", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "88.4", "87.3", "", "69.3", "", "2", "", "", "104", "1", "2", "146", "1", "0", "", "", "0", "0", "", "", "", "", "1", "7.5959", "0.1755", "0.008", "1.46665", "", "", "", "", "", "1", "1", "0", "0035", "", "", "", "", "", "", "", "", "89.8", "96.9", "", "", "", "", "95.6"]} +{"pcdb_id": 16137, "brand_name": "Ideal", "model_name": "Logic combi", "model_qualifier": "30", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 69.8, "output_kw_max": 24.2, "final_year_of_manufacture": 2016, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0099, "loss_factor_f1_kwh_per_day": 1.41408, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016137", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "Logic combi", "30", "47-348-57", "2009", "2016", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "88.4", "87.3", "", "69.8", "", "2", "", "", "104", "1", "2", "152", "1", "0", "", "", "0", "0", "", "", "", "", "1", "7.548", "0.1749", "0.0099", "1.41408", "", "", "", "", "", "1", "1", "0", "0035", "", "", "", "", "", "", "", "", "90.0", "96.9", "", "", "", "", "95.6"]} +{"pcdb_id": 16138, "brand_name": "Ideal", "model_name": "Logic combi", "model_qualifier": "35", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 71.0, "output_kw_max": 24.2, "final_year_of_manufacture": 2016, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0087, "loss_factor_f1_kwh_per_day": 1.2937, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016138", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "Logic combi", "35", "47-348-58", "2009", "2016", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "88.3", "87.3", "", "71.0", "", "2", "", "", "104", "1", "2", "177", "1", "0", "", "", "0", "0", "", "", "", "", "1", "7.4216", "0.171", "0.0087", "1.2937", "", "", "", "", "", "1", "1", "0", "0035", "", "", "", "", "", "", "", "", "89.8", "96.9", "", "", "", "", "95.5"]} +{"pcdb_id": 16139, "brand_name": "Worcester", "model_name": "Greenstar Camray External System", "model_qualifier": "12/18", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 58.7, "output_kw_max": 18.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016139", "000035", "0", "2020/Sep/08 10:23", "Bosch Thermotechnology", "Worcester", "Greenstar Camray External System", "12/18", "Greenstar Camray 12/18-ROO-GB Ext Sys", "2009", "2015", "4", "1", "2", "1", "0", "", "", "2", "2", "2", "12", "18", "", "", "88.1", "80.3", "", "58.7", "", "2", "", "", "201", "1", "1", "265", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.4", "94.8", "", "", "", "", "94.2"]} +{"pcdb_id": 16140, "brand_name": "Worcester", "model_name": "Greenstar Camray External System", "model_qualifier": "18/25", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 80.6, "comparative_hot_water_efficiency_pct": 58.9, "output_kw_max": 25.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016140", "000035", "0", "2020/Sep/08 10:24", "Bosch Thermotechnology", "Worcester", "Greenstar Camray External System", "18/25", "Greenstar Camray 18/25-ROO0GB Ext Sys", "2009", "2015", "4", "1", "2", "1", "0", "", "", "2", "2", "2", "18", "25", "", "", "88.4", "80.6", "", "58.9", "", "2", "", "", "201", "1", "1", "265", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.5", "95.9", "", "", "", "", "94.8"]} +{"pcdb_id": 16141, "brand_name": "Worcester", "model_name": "Greenstar Camray External System", "model_qualifier": "25/32", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 81.1, "comparative_hot_water_efficiency_pct": 59.3, "output_kw_max": 30.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016141", "000035", "0", "2020/Sep/08 10:24", "Bosch Thermotechnology", "Worcester", "Greenstar Camray External System", "25/32", "", "2009", "2015", "4", "1", "2", "1", "0", "", "", "2", "2", "2", "25", "30", "", "", "88.9", "81.1", "", "59.3", "", "2", "", "", "201", "1", "1", "265", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.5", "96.9", "", "", "", "", "95.9"]} +{"pcdb_id": 16142, "brand_name": "Wolf", "model_name": "COB-29", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 59.0, "output_kw_max": 29.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016142", "000240", "0", "2012/Mar/27 10:12", "Wolf", "Wolf", "COB-29", "", "", "2007", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "19.6", "29.6", "", "", "88.6", "80.8", "", "59.0", "", "2", "", "", "201", "1", "2", "73.5", "4.5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.5", "96.5", "", "", "", "", "95.4"]} +{"pcdb_id": 16143, "brand_name": "Wolf", "model_name": "COB-20", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 59.0, "output_kw_max": 20.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016143", "000240", "0", "2012/Mar/27 10:12", "Wolf", "Wolf", "COB-20", "", "", "2007", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "13.9", "20.0", "", "", "88.6", "80.8", "", "59.0", "", "2", "", "", "201", "1", "2", "63.5", "5.9", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "91.0", "96.2", "", "", "", "", "95.2"]} +{"pcdb_id": 16144, "brand_name": "Potterton", "model_name": "Heatmax Combi", "model_qualifier": "24 HE", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 56.1, "output_kw_max": 20.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016144", "000005", "0", "2015/Aug/06 12:58", "Baxi Heating", "Potterton", "Heatmax Combi", "24 HE", "GC No. 47-393-27", "2009", "2015", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "20.0", "20.0", "", "", "88.4", "79.8", "", "56.1", "", "2", "", "", "104", "1", "2", "155", "5", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "90.0", "96.9", "", "", "", "", "95.6"]} +{"pcdb_id": 16145, "brand_name": "Potterton", "model_name": "Heatmax Combi", "model_qualifier": "28 HE", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 56.1, "output_kw_max": 24.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016145", "000005", "0", "2015/Aug/06 12:58", "Baxi", "Potterton", "Heatmax Combi", "28 HE", "GC No 47-393-28", "2009", "2015", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.0", "24.0", "", "", "88.4", "79.8", "", "56.1", "", "2", "", "", "104", "1", "2", "155", "5", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "90.0", "96.9", "", "", "", "", "95.6"]} +{"pcdb_id": 16146, "brand_name": "Potterton", "model_name": "Heatmax Combi", "model_qualifier": "33 HE", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 56.0, "output_kw_max": 28.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016146", "000005", "0", "2015/Aug/06 12:59", "Baxi", "Potterton", "Heatmax Combi", "33 HE", "GC No. 47-393-29", "2009", "2015", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28.0", "28.0", "", "", "88.3", "79.7", "", "56.0", "", "2", "", "", "104", "1", "2", "160", "5", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "90.0", "96.7", "", "", "", "", "95.4"]} +{"pcdb_id": 16147, "brand_name": "Intergas", "model_name": "Combi Compact HRE 24/18", "model_qualifier": "", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 86.6, "comparative_hot_water_efficiency_pct": 72.1, "output_kw_max": 18.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.011, "loss_factor_f1_kwh_per_day": 1.10948, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016147", "000256", "0", "2014/Dec/01 15:19", "Intergas Heating Ltd", "Intergas", "Combi Compact HRE 24/18", "", "", "2009", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "18.2", "18.2", "", "", "88.2", "86.6", "", "72.1", "", "2", "", "", "104", "1", "2", "130", "1.9", "0", "", "", "", "0", "", "", "", "", "1", "7.302", "0.141", "0.011", "1.10948", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "97.4", "", "", "", "", "95.6"]} +{"pcdb_id": 16148, "brand_name": "Pro", "model_name": "A28", "model_qualifier": "", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 56.0, "output_kw_max": 19.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016148", "000011", "0", "2009/Jul/29 07:37", "Vokera", "Pro", "A28", "", "47-094-96", "2008", "current", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "19.6", "19.6", "", "", "88.2", "79.6", "", "56.0", "", "2", "", "", "104", "1", "2", "150", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.5", "97.0", "", "", "", "", "95.4"]} +{"pcdb_id": 16149, "brand_name": "Pro", "model_name": "A32", "model_qualifier": "", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 55.9, "output_kw_max": 24.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016149", "000011", "0", "2009/Jul/29 07:37", "Vokera", "Pro", "A32", "", "47-094-97", "2008", "current", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "24.4", "24.4", "", "", "88.2", "79.6", "", "55.9", "", "2", "", "", "104", "1", "2", "150", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.1", "97.1", "", "", "", "", "95.4"]} +{"pcdb_id": 16150, "brand_name": "Pro", "model_name": "A36", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 55.9, "output_kw_max": 29.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016150", "000011", "0", "2009/Jul/29 07:37", "Vokera", "Pro", "A36", "", "47-094-98", "2008", "current", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "29.3", "29.3", "", "", "88.1", "79.5", "", "55.9", "", "2", "", "", "104", "1", "2", "150", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "97.1", "", "", "", "", "95.4"]} +{"pcdb_id": 16151, "brand_name": "Vokera", "model_name": "Mynute", "model_qualifier": "29EHE", "winter_efficiency_pct": 85.2, "summer_efficiency_pct": 76.2, "comparative_hot_water_efficiency_pct": 55.6, "output_kw_max": 28.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016151", "000011", "0", "2012/Mar/27 10:12", "Vokera", "Vokera", "Mynute", "29EHE", "", "2008", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "28.30", "28.30", "", "", "85.2", "76.2", "", "55.6", "", "2", "", "", "102", "1", "2", "150", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "89.6", "", "", "", "", "89.3"]} +{"pcdb_id": 16152, "brand_name": "Vokera", "model_name": "Mynute", "model_qualifier": "25EHE", "winter_efficiency_pct": 85.4, "summer_efficiency_pct": 76.4, "comparative_hot_water_efficiency_pct": 55.8, "output_kw_max": 24.35, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016152", "000011", "0", "2012/Mar/27 10:12", "Vokera", "Vokera", "Mynute", "25EHE", "", "2008", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "24.35", "24.35", "", "", "85.4", "76.4", "", "55.8", "", "2", "", "", "102", "1", "2", "150", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "90.2", "", "", "", "", "89.7"]} +{"pcdb_id": 16154, "brand_name": "ARCA", "model_name": "Pixel 31 FCR", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 30.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016154", "000261", "0", "2012/Mar/27 10:12", "ARCA", "ARCA", "Pixel 31 FCR", "", "", "2005", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "30.2", "30.2", "", "", "88.5", "79.5", "", "58.1", "", "2", "", "", "102", "1", "2", "150", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "98.0", "", "", "", "", "96.1"]} +{"pcdb_id": 16155, "brand_name": "Intergas", "model_name": "Compact HRE 18 SB", "model_qualifier": "", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 18.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016155", "000256", "0", "2012/Mar/27 10:12", "Intergas Heating Ltd", "Intergas", "Compact HRE 18 SB", "", "", "2009", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18.2", "18.2", "", "", "88.2", "79.2", "", "57.9", "", "2", "", "", "102", "1", "2", "130", "1.9", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "97.4", "", "", "", "", "95.6"]} +{"pcdb_id": 16156, "brand_name": "Intergas", "model_name": "Compact HRE 24 SB", "model_qualifier": "", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 23.1, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016156", "000256", "0", "2012/Mar/27 10:12", "Intergas Heating Ltd", "Intergas", "Compact HRE 24 SB", "", "", "2009", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "23.1", "23.1", "", "", "88.2", "79.2", "", "57.8", "", "2", "", "", "102", "1", "2", "130", "1.9", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "97.2", "", "", "", "", "95.5"]} +{"pcdb_id": 16157, "brand_name": "Intergas", "model_name": "Compact HRE 30 SB", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 26.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016157", "000256", "0", "2012/Mar/27 10:12", "Intergas Heating Ltd", "Intergas", "Compact HRE 30 SB", "", "", "2009", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "26.6", "26.6", "", "", "88.5", "79.5", "", "58.0", "", "2", "", "", "102", "1", "2", "130", "1.9", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.9", "97.6", "", "", "", "", "95.9"]} +{"pcdb_id": 16159, "brand_name": "ARCA", "model_name": "Pixel 31 FC", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 56.2, "output_kw_max": 30.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016159", "000261", "0", "2009/Jul/30 14:29", "ARCA", "ARCA", "Pixel 31 FC", "", "", "2005", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "30.2", "30.2", "", "", "88.5", "79.9", "", "56.2", "", "2", "", "", "104", "1", "2", "150", "5", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "97.9", "", "", "", "", "96.1"]} +{"pcdb_id": 16161, "brand_name": "ARCA", "model_name": "Pixel 25 FCR", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 24.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016161", "000261", "0", "2012/Mar/27 10:12", "ARCA", "ARCA", "Pixel 25 FCR", "", "", "2005", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24.4", "24.4", "", "", "88.5", "79.5", "", "58.0", "", "2", "", "", "102", "1", "2", "150", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "97.9", "", "", "", "", "96.1"]} +{"pcdb_id": 16164, "brand_name": "ARCA", "model_name": "Pixel 25 FC", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 56.2, "output_kw_max": 24.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016164", "000261", "0", "2009/Jul/30 14:30", "ARCA", "ARCA", "Pixel 25 FC", "", "", "2005", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.4", "24.4", "", "", "88.5", "79.9", "", "56.2", "", "2", "", "", "104", "1", "2", "150", "5", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "97.9", "", "", "", "", "96.1"]} +{"pcdb_id": 16165, "brand_name": "ATAG", "model_name": "A200S", "model_qualifier": "", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 17.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016165", "000227", "0", "2012/Mar/27 10:12", "ATAG Verwarming Nederland BV", "ATAG", "A200S", "", "", "2009", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "17.6", "17.6", "", "", "88.7", "79.7", "", "58.2", "", "2", "", "", "102", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.2", "98.4", "", "", "", "", "96.5"]} +{"pcdb_id": 16166, "brand_name": "ATAG", "model_name": "A200S OV", "model_qualifier": "", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 17.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016166", "000227", "0", "2012/Mar/27 10:12", "ATAG Verwarming Nederland BV", "ATAG", "A200S OV", "", "", "2009", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "17.6", "17.6", "", "", "88.7", "79.7", "", "58.2", "", "2", "", "", "102", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.2", "98.4", "", "", "", "", "96.5"]} +{"pcdb_id": 16167, "brand_name": "ATAG", "model_name": "A203C", "model_qualifier": "", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 56.3, "output_kw_max": 17.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016167", "000227", "0", "2009/Oct/22 11:42", "ATAG Verwarming Nederland BV", "ATAG", "A203C", "", "", "2009", "current", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "17.6", "17.6", "", "", "88.7", "80.1", "", "56.3", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.2", "98.4", "", "", "", "", "96.5"]} +{"pcdb_id": 16169, "brand_name": "ATAG", "model_name": "A320S", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 28.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016169", "000227", "0", "2012/Mar/27 10:12", "ATAG Verwarming Nederland BV", "ATAG", "A320S", "", "", "2009", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "28.2", "28.2", "", "", "88.8", "79.8", "", "58.3", "", "2", "", "", "102", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.2", "98.8", "", "", "", "", "96.8"]} +{"pcdb_id": 16170, "brand_name": "ATAG", "model_name": "A325C", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 56.4, "output_kw_max": 28.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016170", "000227", "0", "2009/Oct/22 11:42", "ATAG Verwarming Nederland BV", "ATAG", "A325C", "", "", "2009", "current", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "28.2", "28.2", "", "", "88.8", "80.2", "", "56.4", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.2", "98.8", "", "", "", "", "96.8"]} +{"pcdb_id": 16171, "brand_name": "ATAG", "model_name": "A325EC", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 56.3, "output_kw_max": 28.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016171", "000227", "0", "2009/Oct/22 11:43", "ATAG Verwarming Nederland BV", "ATAG", "A325EC", "", "", "2009", "current", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "28.2", "28.2", "", "", "88.6", "80.0", "", "56.3", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "98.3", "", "", "", "", "96.4"]} +{"pcdb_id": 16172, "brand_name": "Glow-worm", "model_name": "Betacom 24c", "model_qualifier": "", "winter_efficiency_pct": 85.9, "summer_efficiency_pct": 77.3, "comparative_hot_water_efficiency_pct": 54.4, "output_kw_max": 24.7, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016172", "000207", "0", "2010/Mar/06 17:48", "Vaillant Group UK", "Glow-worm", "Betacom 24c", "", "", "2008", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24.7", "24.7", "", "", "85.9", "77.3", "", "54.4", "", "2", "1", "", "104", "1", "2", "164", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.4", "91.7", "", "", "", "", "91.1"]} +{"pcdb_id": 16173, "brand_name": "Glow-worm", "model_name": "Betacom 30c", "model_qualifier": "", "winter_efficiency_pct": 86.0, "summer_efficiency_pct": 77.4, "comparative_hot_water_efficiency_pct": 54.5, "output_kw_max": 27.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016173", "000207", "0", "2010/Mar/06 17:48", "Vaillant Group UK", "Glow-worm", "Betacom 30c", "", "", "2008", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "27.6", "27.6", "", "", "86.0", "77.4", "", "54.5", "", "2", "1", "", "104", "1", "2", "164", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.2", "91.7", "", "", "", "", "91.2"]} +{"pcdb_id": 16174, "brand_name": "Heatline", "model_name": "Sargon 18S", "model_qualifier": "", "winter_efficiency_pct": 87.8, "summer_efficiency_pct": 78.8, "comparative_hot_water_efficiency_pct": 57.6, "output_kw_max": 19.5, "final_year_of_manufacture": 2009, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016174", "000215", "0", "2012/Mar/27 10:12", "DD Heating", "Heatline", "Sargon 18S", "", "41-157-12", "2008", "2009", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "19.5", "19.5", "", "", "87.8", "78.8", "", "57.6", "", "2", "", "", "102", "1", "2", "175", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "96.4", "", "", "", "", "94.8"]} +{"pcdb_id": 16176, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "15 i System", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 15.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016176", "000035", "0", "2020/Sep/08 10:24", "Bosch Thermotechnology", "Worcester", "Greenstar", "15 i System", "", "2009", "2015", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "15", "15", "", "", "89.1", "80.1", "", "58.5", "", "2", "1", "", "102", "1", "2", "140", "9.6", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0305", "", "", "", "", "", "", "", "", "89.7", "99.2", "", "", "", "", "97.4"]} +{"pcdb_id": 16177, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "15 i System", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 15.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016177", "000035", "0", "2020/Sep/08 10:25", "Bosch Thermotechnology", "Worcester", "Greenstar", "15 i System", "41-311-84", "2009", "2015", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "15.0", "15.0", "", "", "88.1", "79.1", "", "57.7", "", "2", "", "", "102", "1", "2", "140", "9.6", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0305", "", "", "", "", "", "", "", "", "87.8", "97.0", "", "", "", "", "95.3"]} +{"pcdb_id": 16178, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "18 i System", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 18.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016178", "000035", "0", "2020/Sep/08 10:25", "Bosch Thermotechnology", "Worcester", "Greenstar", "18 i System", "", "2009", "2015", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "18.0", "18.0", "", "", "89.1", "80.1", "", "58.5", "", "2", "1", "", "102", "1", "2", "140", "9.6", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0305", "", "", "", "", "", "", "", "", "89.7", "99.2", "", "", "", "", "97.4"]} +{"pcdb_id": 16179, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "18 i System", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 18.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016179", "000035", "0", "2020/Sep/08 10:25", "Bosch Thermotechnology", "Worcester", "Greenstar", "18 i System", "41-311-86", "2009", "2015", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18.0", "18.0", "", "", "88.1", "79.1", "", "57.7", "", "2", "", "", "102", "1", "2", "140", "9.6", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0305", "", "", "", "", "", "", "", "", "87.8", "97.0", "", "", "", "", "95.3"]} +{"pcdb_id": 16180, "brand_name": "Viessmann", "model_name": "Vitodens 100 W WB1B", "model_qualifier": "13kW Regular Boiler open vent", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 80.4, "comparative_hot_water_efficiency_pct": 58.7, "output_kw_max": 11.9, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016180", "000033", "0", "2017/Feb/20 10:57", "Viessmann", "Viessmann", "Vitodens 100 W WB1B", "13kW Regular Boiler open vent", "", "2009", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "11.9", "11.9", "", "", "89.4", "80.4", "", "58.7", "", "2", "1", "", "102", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "", "", "", "", "90.0", "99.8", "", "", "", "", "98.0"]} +{"pcdb_id": 16181, "brand_name": "Viessmann", "model_name": "Vitodens 100 W WB1B", "model_qualifier": "13kW Regular Boiler open vent", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 11.9, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016181", "000033", "0", "2017/Feb/20 10:57", "Viessmann", "Viessmann", "Vitodens 100 W WB1B", "13kW Regular Boiler open vent", "41-819-21", "2009", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "11.9", "11.9", "", "", "88.3", "79.3", "", "58.0", "", "2", "", "", "102", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "", "", "", "", "88.0", "97.7", "", "", "", "", "95.8"]} +{"pcdb_id": 16182, "brand_name": "Viessmann", "model_name": "Vitodens 100 W WB1B", "model_qualifier": "16kW Regular Boiler open vent", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 80.4, "comparative_hot_water_efficiency_pct": 58.7, "output_kw_max": 14.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016182", "000033", "0", "2017/Feb/20 10:57", "Viessmann", "Viessmann", "Vitodens 100 W WB1B", "16kW Regular Boiler open vent", "", "2009", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "14.6", "14.6", "", "", "89.4", "80.4", "", "58.7", "", "2", "1", "", "102", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "", "", "", "", "90.1", "99.8", "", "", "", "", "98.0"]} +{"pcdb_id": 16183, "brand_name": "Viessmann", "model_name": "Vitodens 100 W WB1B", "model_qualifier": "16kW Regular Boiler open vent", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 14.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016183", "000033", "0", "2017/Feb/20 10:57", "Viessmann", "Viessmann", "Vitodens 100 W WB1B", "16kW Regular Boiler open vent", "41-819-22", "2009", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "14.6", "14.6", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "", "", "", "", "88.1", "97.7", "", "", "", "", "95.9"]} +{"pcdb_id": 16184, "brand_name": "Viessmann", "model_name": "Vitodens 100 W WB1B", "model_qualifier": "19kW Regular Boiler open vent", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 80.4, "comparative_hot_water_efficiency_pct": 58.7, "output_kw_max": 17.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016184", "000033", "0", "2017/Feb/20 10:57", "Viessmann", "Viessmann", "Vitodens 100 W WB1B", "19kW Regular Boiler open vent", "", "2009", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "17.3", "17.3", "", "", "89.4", "80.4", "", "58.7", "", "2", "1", "", "102", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "", "", "", "", "90.0", "99.8", "", "", "", "", "98.0"]} +{"pcdb_id": 16185, "brand_name": "Viessmann", "model_name": "Vitodens 100 W WB1B", "model_qualifier": "19kW Regular Boiler open vent", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 17.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016185", "000033", "0", "2017/Feb/20 10:57", "Viessmann", "Viessmann", "Vitodens 100 W WB1B", "19kW Regular Boiler open vent", "41-819-23", "2009", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "1", "17.3", "17.3", "", "", "88.3", "79.3", "", "58.0", "", "2", "", "", "102", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "", "", "", "", "88.0", "97.7", "", "", "", "", "95.8"]} +{"pcdb_id": 16186, "brand_name": "Viessmann", "model_name": "Vitodens 100 W WB1B", "model_qualifier": "26kW Regular Boiler open vent", "winter_efficiency_pct": 89.6, "summer_efficiency_pct": 80.6, "comparative_hot_water_efficiency_pct": 58.9, "output_kw_max": 23.7, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016186", "000033", "0", "2017/Feb/20 10:57", "Viessmann", "Viessmann", "Vitodens 100 W WB1B", "26kW Regular Boiler open vent", "", "2009", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "23.7", "23.7", "", "", "89.6", "80.6", "", "58.9", "", "2", "1", "", "102", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "", "", "", "", "90.3", "100.4", "", "", "", "", "98.5"]} +{"pcdb_id": 16187, "brand_name": "Viessmann", "model_name": "Vitodens 100 W WB1B", "model_qualifier": "26kW Regular Boiler open vent", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 23.7, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016187", "000033", "0", "2012/Aug/28 09:58", "Viessmann", "Viessmann", "Vitodens 100 W WB1B", "26kW Regular Boiler open vent", "41-819-24", "2009", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "23.7", "23.7", "", "", "88.6", "79.6", "", "58.1", "", "2", "", "", "102", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "98.2", "", "", "", "", "96.3"]} +{"pcdb_id": 16189, "brand_name": "Ferroli", "model_name": "DOMIcondens", "model_qualifier": "F28", "winter_efficiency_pct": 86.4, "summer_efficiency_pct": 77.8, "comparative_hot_water_efficiency_pct": 54.7, "output_kw_max": 26.2, "final_year_of_manufacture": 2017, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016189", "000097", "0", "2017/Aug/21 13:37", "Ferroli", "Ferroli", "DOMIcondens", "F28", "47-267-46", "2009", "2017", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "26.2", "26.2", "", "", "86.4", "77.8", "", "54.7", "", "2", "", "", "104", "1", "2", "135", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "0", "", "0005", "", "", "", "", "", "", "", "", "86.9", "93.3", "", "", "", "", "92.1"]} +{"pcdb_id": 16190, "brand_name": "Ferroli", "model_name": "DOMIcondens", "model_qualifier": "F28", "winter_efficiency_pct": 87.4, "summer_efficiency_pct": 78.8, "comparative_hot_water_efficiency_pct": 55.4, "output_kw_max": 26.2, "final_year_of_manufacture": 2017, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016190", "000097", "0", "2017/Aug/21 13:38", "Ferroli", "Ferroli", "DOMIcondens", "F28", "", "2009", "2017", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "26.2", "26.2", "", "", "87.4", "78.8", "", "55.4", "", "2", "1", "", "104", "1", "2", "135", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "0", "", "0005", "", "", "", "", "", "", "", "", "88.9", "95.3", "", "", "", "", "94.1"]} +{"pcdb_id": 16191, "brand_name": "HRM", "model_name": "X-Ternal System", "model_qualifier": "12/14 Condensing a", "winter_efficiency_pct": 86.9, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 15.7, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016191", "000098", "0", "2012/Mar/27 10:12", "HRM Boilers", "HRM", "X-Ternal System", "12/14 Condensing a", "", "2009", "current", "4", "2", "2", "1", "0", "", "", "2", "2", "2", "12", "15.7", "", "", "86.9", "79.1", "", "57.8", "", "2", "", "", "201", "1", "1", "110", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.0", "92.3", "", "", "", "", "91.8"]} +{"pcdb_id": 16193, "brand_name": "HRM", "model_name": "Wallstar", "model_qualifier": "12/14 Condensing a", "winter_efficiency_pct": 86.9, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 15.7, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016193", "000098", "0", "2012/Mar/27 10:12", "HRM Boilers", "HRM", "Wallstar", "12/14 Condensing a", "", "2009", "current", "4", "2", "1", "1", "0", "", "", "2", "2", "2", "12", "15.7", "", "", "86.9", "79.1", "", "57.8", "", "2", "", "", "201", "1", "1", "110", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.0", "92.3", "", "", "", "", "91.8"]} +{"pcdb_id": 16194, "brand_name": "HRM", "model_name": "Wallstar", "model_qualifier": "15/19 Condensing a", "winter_efficiency_pct": 86.8, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 19.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016194", "000098", "0", "2012/Mar/27 10:12", "HRM Boilers", "HRM", "Wallstar", "15/19 Condensing a", "", "2009", "current", "4", "2", "1", "1", "0", "", "", "2", "2", "2", "15", "19", "", "", "86.8", "79.0", "", "57.7", "", "2", "", "", "201", "1", "1", "110", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.5", "91.5", "", "", "", "", "91.5"]} +{"pcdb_id": 16195, "brand_name": "HRM", "model_name": "Wallstar System", "model_qualifier": "15/19 Condensing a", "winter_efficiency_pct": 86.8, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 19.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016195", "000098", "0", "2012/Mar/27 10:12", "HRM Boilers", "HRM", "Wallstar System", "15/19 Condensing a", "", "2009", "current", "4", "2", "1", "1", "0", "", "", "2", "2", "2", "15", "19", "", "", "86.8", "79.0", "", "57.7", "", "2", "", "", "201", "1", "1", "110", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.5", "91.5", "", "", "", "", "91.5"]} +{"pcdb_id": 16196, "brand_name": "HRM", "model_name": "X-Ternal", "model_qualifier": "15/19 Condensing a", "winter_efficiency_pct": 86.8, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 19.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016196", "000098", "0", "2012/Mar/27 10:12", "HRM Boilers", "HRM", "X-Ternal", "15/19 Condensing a", "", "2009", "current", "4", "2", "2", "1", "0", "", "", "2", "2", "2", "15", "19", "", "", "86.8", "79.0", "", "57.7", "", "2", "", "", "201", "1", "1", "110", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.5", "91.5", "", "", "", "", "91.5"]} +{"pcdb_id": 16197, "brand_name": "Biasi", "model_name": "ActivA", "model_qualifier": "25S", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 24.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016197", "000208", "0", "2012/Jun/28 11:08", "Biasi (UK)", "Biasi", "ActivA", "25S", "41-583-12", "2009", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24.5", "24.5", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "140", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.1", "96.9", "", "", "", "", "95.2"]} +{"pcdb_id": 16198, "brand_name": "Biasi", "model_name": "ActivA", "model_qualifier": "18S", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 17.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016198", "000208", "0", "2012/Jun/28 11:08", "Biasi (UK)", "Biasi", "ActivA", "18S", "41-583-11", "2009", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "17.6", "17.6", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "140", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.1", "96.8", "", "", "", "", "95.1"]} +{"pcdb_id": 16200, "brand_name": "Biasi", "model_name": "ActivA", "model_qualifier": "35C", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 56.0, "output_kw_max": 29.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016200", "000208", "0", "2011/Sep/30 11:49", "Biasi (UK)", "Biasi", "ActivA", "35C", "47-583-23", "2009", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "29.2", "29.2", "", "", "88.2", "79.6", "", "56.0", "", "2", "", "", "104", "1", "2", "140", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.1", "97.3", "", "", "", "", "95.6"]} +{"pcdb_id": 16201, "brand_name": "Biasi", "model_name": "ActivA", "model_qualifier": "30C", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 55.9, "output_kw_max": 24.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016201", "000208", "0", "2011/Sep/30 11:49", "Biasi (UK)", "Biasi", "ActivA", "30C", "47-583-22", "2009", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.5", "24.5", "", "", "88.0", "79.4", "", "55.9", "", "2", "", "", "104", "1", "2", "140", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.1", "96.9", "", "", "", "", "95.2"]} +{"pcdb_id": 16202, "brand_name": "Biasi", "model_name": "ActivA", "model_qualifier": "25C", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 56.0, "output_kw_max": 19.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016202", "000208", "0", "2011/Sep/30 11:49", "Biasi (UK)", "Biasi", "ActivA", "25C", "47-583-21", "2009", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "19.5", "19.5", "", "", "88.2", "79.6", "", "56.0", "", "2", "", "", "104", "1", "2", "140", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.1", "97.3", "", "", "", "", "95.6"]} +{"pcdb_id": 16203, "brand_name": "Biasi", "model_name": "ActivA", "model_qualifier": "30S", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 29.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016203", "000208", "0", "2012/Jun/28 11:08", "Biasi (UK)", "Biasi", "ActivA", "30S", "41-583-13", "2009", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "29.2", "29.2", "", "", "88.2", "79.2", "", "57.9", "", "2", "", "", "102", "1", "2", "140", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.1", "97.3", "", "", "", "", "95.6"]} +{"pcdb_id": 16204, "brand_name": "Biasi", "model_name": "ActivA", "model_qualifier": "25S", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 24.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016204", "000208", "0", "2012/Mar/27 10:12", "Biasi (UK)", "Biasi", "ActivA", "25S", "", "2009", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "24.5", "24.5", "", "", "89.0", "80.0", "", "58.5", "", "2", "1", "", "102", "1", "2", "140", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.1", "99.0", "", "", "", "", "97.3"]} +{"pcdb_id": 16205, "brand_name": "Biasi", "model_name": "ActivA", "model_qualifier": "18S", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 17.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016205", "000208", "0", "2012/Mar/27 10:12", "Biasi (UK)", "Biasi", "ActivA", "18S", "", "2009", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "17.6", "17.6", "", "", "89.0", "80.0", "", "58.4", "", "2", "1", "", "102", "1", "2", "140", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.1", "98.9", "", "", "", "", "97.2"]} +{"pcdb_id": 16206, "brand_name": "Biasi", "model_name": "ActivA", "model_qualifier": "35C", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 80.6, "comparative_hot_water_efficiency_pct": 56.7, "output_kw_max": 29.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016206", "000208", "0", "2009/Sep/24 12:10", "Biasi (UK)", "Biasi", "ActivA", "35C", "", "2009", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "29.2", "29.2", "", "", "89.2", "80.6", "", "56.7", "", "2", "1", "", "104", "1", "2", "140", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.1", "99.5", "", "", "", "", "97.7"]} +{"pcdb_id": 16207, "brand_name": "Biasi", "model_name": "ActivA", "model_qualifier": "30C", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.4, "comparative_hot_water_efficiency_pct": 56.6, "output_kw_max": 24.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016207", "000208", "0", "2009/Sep/24 12:09", "Biasi (UK)", "Biasi", "ActivA", "30C", "", "2009", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24.5", "24.5", "", "", "89.0", "80.4", "", "56.6", "", "2", "1", "", "104", "1", "2", "140", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.1", "99.0", "", "", "", "", "97.3"]} +{"pcdb_id": 16208, "brand_name": "Biasi", "model_name": "ActivA", "model_qualifier": "25C", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 80.6, "comparative_hot_water_efficiency_pct": 56.7, "output_kw_max": 19.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016208", "000208", "0", "2009/Sep/24 12:09", "Biasi (UK)", "Biasi", "ActivA", "25C", "", "2009", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "19.5", "19.5", "", "", "89.2", "80.6", "", "56.7", "", "2", "1", "", "104", "1", "2", "140", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.1", "99.5", "", "", "", "", "97.7"]} +{"pcdb_id": 16209, "brand_name": "Biasi", "model_name": "ActivA", "model_qualifier": "30S", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 29.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016209", "000208", "0", "2012/Mar/27 10:12", "Biasi (UK)", "Biasi", "ActivA", "30S", "", "2009", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "29.2", "29.2", "", "", "89.2", "80.2", "", "58.6", "", "2", "1", "", "102", "1", "2", "140", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.1", "99.5", "", "", "", "", "97.7"]} +{"pcdb_id": 16210, "brand_name": "Ideal", "model_name": "Logic+ combi", "model_qualifier": "30", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 69.8, "output_kw_max": 24.2, "final_year_of_manufacture": 2016, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0099, "loss_factor_f1_kwh_per_day": 1.41408, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016210", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "Logic+ combi", "30", "47-348-66", "2009", "2016", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "88.4", "87.3", "", "69.8", "", "2", "", "", "104", "1", "2", "152", "1", "0", "", "", "0", "0", "", "", "", "", "1", "7.548", "0.1749", "0.0099", "1.41408", "", "", "", "", "", "1", "1", "0", "0035", "", "", "", "", "", "", "", "", "90.0", "96.9", "", "", "", "", "95.6"]} +{"pcdb_id": 16211, "brand_name": "Ideal", "model_name": "Logic+ combi", "model_qualifier": "35", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 71.0, "output_kw_max": 24.2, "final_year_of_manufacture": 2016, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0087, "loss_factor_f1_kwh_per_day": 1.2937, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016211", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "Logic+ combi", "35", "47-348-67", "2009", "2016", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "88.3", "87.3", "", "71.0", "", "2", "", "", "104", "1", "2", "177", "1", "0", "", "", "0", "0", "", "", "", "", "1", "7.4216", "0.171", "0.0087", "1.2937", "", "", "", "", "", "1", "1", "0", "0035", "", "", "", "", "", "", "", "", "89.8", "96.9", "", "", "", "", "95.5"]} +{"pcdb_id": 16212, "brand_name": "Ideal", "model_name": "Logic+ combi", "model_qualifier": "24", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 69.3, "output_kw_max": 24.2, "final_year_of_manufacture": 2016, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.008, "loss_factor_f1_kwh_per_day": 1.46665, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016212", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "Logic+ combi", "24", "47-348-65", "2009", "2016", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "88.4", "87.3", "", "69.3", "", "2", "", "", "104", "1", "2", "146", "1", "0", "", "", "0", "0", "", "", "", "", "1", "7.5959", "0.1755", "0.008", "1.46665", "", "", "", "", "", "1", "1", "0", "0035", "", "", "", "", "", "", "", "", "89.8", "96.9", "", "", "", "", "95.6"]} +{"pcdb_id": 16213, "brand_name": "Johnson & Starley", "model_name": "RenoXtra", "model_qualifier": "30CA", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 56.4, "output_kw_max": 24.8, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016213", "000239", "0", "2012/Feb/24 10:18", "Johnson & Starley", "Johnson & Starley", "RenoXtra", "30CA", "", "2008", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.8", "24.8", "", "", "88.8", "80.2", "", "56.4", "", "2", "", "", "104", "1", "2", "170", "4.59", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "98.8", "", "", "", "", "96.8"]} +{"pcdb_id": 16214, "brand_name": "Baxi", "model_name": "Duo-tec Combi", "model_qualifier": "24 HE LPG", "winter_efficiency_pct": 90.4, "summer_efficiency_pct": 81.8, "comparative_hot_water_efficiency_pct": 57.5, "output_kw_max": 20.0, "final_year_of_manufacture": 2012, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016214", "000005", "0", "2013/May/07 10:36", "Baxi Heating UK", "Baxi", "Duo-tec Combi", "24 HE LPG", "GC No. 47-075-48", "2009", "2012", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "20.0", "20.0", "", "", "90.4", "81.8", "", "57.5", "", "2", "0", "", "104", "1", "2", "155", "4.76", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "92.0", "99.0", "", "", "", "", "97.7"]} +{"pcdb_id": 16215, "brand_name": "Baxi", "model_name": "Duo-tec Combi", "model_qualifier": "33 HE LPG", "winter_efficiency_pct": 90.3, "summer_efficiency_pct": 81.7, "comparative_hot_water_efficiency_pct": 57.5, "output_kw_max": 28.0, "final_year_of_manufacture": 2012, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016215", "000005", "0", "2013/May/07 10:36", "Baxi Heating UK", "Baxi", "Duo-tec Combi", "33 HE LPG", "GC No. 47-075-49", "2009", "2012", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "28.0", "28.0", "", "", "90.3", "81.7", "", "57.5", "", "2", "0", "", "104", "1", "2", "160", "4.74", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "92.0", "98.8", "", "", "", "", "97.5"]} +{"pcdb_id": 16216, "brand_name": "Baxi", "model_name": "Megaflo System", "model_qualifier": "18 HE LPG", "winter_efficiency_pct": 90.4, "summer_efficiency_pct": 81.4, "comparative_hot_water_efficiency_pct": 59.4, "output_kw_max": 18.0, "final_year_of_manufacture": 2012, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016216", "000005", "0", "2013/May/07 10:36", "Baxi Heating UK", "Baxi", "Megaflo System", "18 HE LPG", "GC No. 47-075-61", "2009", "2012", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "18.0", "18.0", "", "", "90.4", "81.4", "", "59.4", "", "2", "0", "", "102", "1", "2", "140", "4.76", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "91.9", "99.0", "", "", "", "", "97.7"]} +{"pcdb_id": 16217, "brand_name": "Baxi", "model_name": "Megaflo System", "model_qualifier": "28 HE LPG", "winter_efficiency_pct": 90.3, "summer_efficiency_pct": 81.3, "comparative_hot_water_efficiency_pct": 59.4, "output_kw_max": 28.0, "final_year_of_manufacture": 2012, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016217", "000005", "0", "2013/May/07 10:37", "Baxi Heating UK", "Baxi", "Megaflo System", "28 HE LPG", "GC No 47-075-62", "2009", "2012", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "28", "28", "", "", "90.3", "81.3", "", "59.4", "", "2", "0", "", "102", "1", "2", "160", "4.73", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "91.9", "98.8", "", "", "", "", "97.5"]} +{"pcdb_id": 16218, "brand_name": "Baxi", "model_name": "Megaflo System", "model_qualifier": "32 HE LPG", "winter_efficiency_pct": 90.3, "summer_efficiency_pct": 81.3, "comparative_hot_water_efficiency_pct": 59.4, "output_kw_max": 32.0, "final_year_of_manufacture": 2012, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016218", "000005", "0", "2013/May/07 10:37", "Baxi Heating UK", "Baxi", "Megaflo System", "32 HE LPG", "GC No. 47-075-63", "2009", "2012", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "32.0", "32.0", "", "", "90.3", "81.3", "", "59.4", "", "2", "0", "", "102", "1", "2", "160", "4.74", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "91.9", "98.8", "", "", "", "", "97.5"]} +{"pcdb_id": 16219, "brand_name": "Baxi", "model_name": "Bermuda BBU", "model_qualifier": "15 HE", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 15.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016219", "000005", "0", "2015/Aug/06 11:55", "Baxi Heating UK", "Baxi", "Bermuda BBU", "15 HE", "GC No. 44-075-09", "2009", "2015", "1", "4", "1", "1", "0", "", "", "2", "2", "2", "15.0", "15.0", "", "", "88.1", "79.1", "", "57.8", "", "2", "", "", "102", "1", "2", "112", "9.7", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "97.0", "", "", "", "", "95.3"]} +{"pcdb_id": 16220, "brand_name": "Firebird", "model_name": "Silver System CR20", "model_qualifier": "", "winter_efficiency_pct": 87.7, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 20.0, "final_year_of_manufacture": 2010, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016220", "000047", "0", "2012/Mar/27 10:12", "Firebird Boilers", "Firebird", "Silver System CR20", "", "", "2009", "2010", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "15", "20", "", "", "87.7", "79.9", "", "58.3", "", "2", "", "", "201", "1", "1", "38", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.6", "93.6", "", "", "", "", "93.2"]} +{"pcdb_id": 16221, "brand_name": "Firebird", "model_name": "Silver System CR26", "model_qualifier": "", "winter_efficiency_pct": 87.4, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 26.0, "final_year_of_manufacture": 2010, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016221", "000047", "0", "2012/Mar/27 10:12", "Firebird Boilers", "Firebird", "Silver System CR26", "", "", "2009", "2010", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "20", "26", "", "", "87.4", "79.6", "", "58.1", "", "2", "", "", "201", "1", "1", "38", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.8", "92.8", "", "", "", "", "92.6"]} +{"pcdb_id": 16222, "brand_name": "Firebird", "model_name": "Silver System CR35", "model_qualifier": "", "winter_efficiency_pct": 86.2, "summer_efficiency_pct": 78.4, "comparative_hot_water_efficiency_pct": 57.3, "output_kw_max": 35.0, "final_year_of_manufacture": 2010, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016222", "000047", "0", "2012/Mar/27 10:12", "Firebird Boilers", "Firebird", "Silver System CR35", "", "", "2009", "2010", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "26", "35", "", "", "86.2", "78.4", "", "57.3", "", "2", "", "", "201", "1", "1", "38", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "89.3", "91.1", "", "", "", "", "90.7"]} +{"pcdb_id": 16223, "brand_name": "Thermeco", "model_name": "12-20 Slimline", "model_qualifier": "12-20 BFILC", "winter_efficiency_pct": 87.8, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 20.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016223", "000051", "0", "2012/Mar/27 10:12", "GAH Heating Products", "Thermeco", "12-20 Slimline", "12-20 BFILC", "", "2009", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "12", "20", "", "", "87.8", "80.0", "", "58.5", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.4", "94.2", "", "", "", "", "93.6"]} +{"pcdb_id": 16224, "brand_name": "Fondital", "model_name": "Tahiti Condensing KR 55 Line Tech", "model_qualifier": "", "winter_efficiency_pct": 89.5, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 58.8, "output_kw_max": 53.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016224", "000250", "0", "2012/Mar/27 10:12", "Fondital", "Fondital", "Tahiti Condensing KR 55 Line Tech", "", "", "2008", "current", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "53.5", "53.5", "", "", "89.5", "80.5", "", "58.8", "", "2", "1", "", "102", "1", "2", "245", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.6", "100.3", "", "", "", "", "98.3"]} +{"pcdb_id": 16225, "brand_name": "Fondital", "model_name": "Tahiti Condensing KR 55 Line Tech", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 53.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016225", "000250", "0", "2012/Mar/27 10:12", "Fondital", "Fondital", "Tahiti Condensing KR 55 Line Tech", "", "", "2008", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "53.5", "53.5", "", "", "88.5", "79.5", "", "58.0", "", "2", "", "", "102", "1", "2", "245", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.7", "98.1", "", "", "", "", "96.1"]} +{"pcdb_id": 16226, "brand_name": "Sime", "model_name": "Murelle EV HE", "model_qualifier": "30/55", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 81.8, "comparative_hot_water_efficiency_pct": 47.2, "output_kw_max": 28.9, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016226", "000213", "0", "2024/Jan/31 10:17", "Fonderie Sime S.p.A.", "Sime", "Murelle EV HE", "30/55", "", "2009", "2018", "2", "2", "1", "2", "0", "", "", "2", "3", "2", "28.9", "28.9", "", "", "89.1", "81.8", "", "47.2", "", "2", "1", "", "106", "1", "2", "115", "8", "2", "1", "0", "48", "0", "20", "5", "60", "275", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.6", "98.9", "", "", "", "", "97.3"]} +{"pcdb_id": 16227, "brand_name": "Sime", "model_name": "Murelle EV HE", "model_qualifier": "30/55", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 46.7, "output_kw_max": 28.9, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016227", "000213", "0", "2024/Jan/31 10:17", "Fonderie Sime S.p.A.", "Sime", "Murelle EV HE", "30/55", "", "2009", "2018", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "28.9", "28.9", "", "", "88.1", "80.8", "", "46.7", "", "2", "", "", "106", "1", "2", "115", "8", "2", "1", "0", "48", "0", "20", "5", "60", "275", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.7", "96.8", "", "", "", "", "95.2"]} +{"pcdb_id": 16228, "brand_name": "Sime", "model_name": "Murelle EV HE", "model_qualifier": "25/55", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 80.7, "comparative_hot_water_efficiency_pct": 46.6, "output_kw_max": 23.9, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016228", "000213", "0", "2024/Jan/31 10:17", "Fonderie Sime S.p.A.", "Sime", "Murelle EV HE", "25/55", "", "2009", "2018", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "23.9", "23.9", "", "", "88.0", "80.7", "", "46.6", "", "2", "", "", "106", "1", "2", "115", "8", "2", "1", "0", "48", "0", "20", "5", "60", "275", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "96.6", "", "", "", "", "95.0"]} +{"pcdb_id": 16229, "brand_name": "Sime", "model_name": "Murelle EV HE", "model_qualifier": "25/55", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 81.7, "comparative_hot_water_efficiency_pct": 47.2, "output_kw_max": 23.9, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016229", "000213", "0", "2024/Jan/31 10:17", "Fonderie Sime S.p.A.", "Sime", "Murelle EV HE", "25/55", "", "2009", "2018", "2", "2", "1", "2", "0", "", "", "2", "3", "2", "23.9", "23.9", "", "", "89.0", "81.7", "", "47.2", "", "2", "1", "", "106", "1", "2", "115", "8", "2", "1", "0", "48", "0", "20", "5", "60", "275", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.3", "98.7", "", "", "", "", "97.1"]} +{"pcdb_id": 16230, "brand_name": "Sime", "model_name": "Murelle EV HE", "model_qualifier": "35", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 55.8, "output_kw_max": 34.1, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016230", "000213", "0", "2018/Mar/05 16:35", "Fonderie Sime S.p.A.", "Sime", "Murelle EV HE", "35", "", "2009", "2018", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "34.1", "34.1", "", "", "88.0", "79.4", "", "55.8", "", "2", "", "", "104", "1", "2", "140", "8", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.5", "96.2", "", "", "", "", "94.9"]} +{"pcdb_id": 16231, "brand_name": "Sime", "model_name": "Murelle EV HE", "model_qualifier": "35", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.4, "comparative_hot_water_efficiency_pct": 56.6, "output_kw_max": 34.1, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016231", "000213", "0", "2018/Mar/05 16:35", "Fonderie Sime S.p.A.", "Sime", "Murelle EV HE", "35", "", "2009", "2018", "2", "2", "1", "2", "0", "", "", "2", "3", "2", "34.1", "34.1", "", "", "89.0", "80.4", "", "56.6", "", "2", "1", "", "104", "1", "2", "140", "8", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "91.5", "98.4", "", "", "", "", "97.1"]} +{"pcdb_id": 16232, "brand_name": "Sime", "model_name": "Murelle EV HE", "model_qualifier": "30", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 56.0, "output_kw_max": 28.9, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016232", "000213", "0", "2018/Mar/05 14:23", "Fonderie Sime S.p.A.", "Sime", "Murelle EV HE", "30", "", "2009", "2018", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "28.9", "28.9", "", "", "88.2", "79.6", "", "56.0", "", "2", "", "", "104", "1", "2", "130", "8", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.7", "97.0", "", "", "", "", "95.4"]} +{"pcdb_id": 16233, "brand_name": "Sime", "model_name": "Murelle EV HE", "model_qualifier": "30", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 80.6, "comparative_hot_water_efficiency_pct": 56.7, "output_kw_max": 28.9, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016233", "000213", "0", "2018/Mar/05 14:24", "Fonderie Sime S.p.A.", "Sime", "Murelle EV HE", "30", "", "2009", "2018", "2", "2", "1", "2", "0", "", "", "2", "3", "2", "28.9", "28.9", "", "", "89.2", "80.6", "", "56.7", "", "2", "1", "", "104", "1", "2", "130", "8", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.6", "99.2", "", "", "", "", "97.6"]} +{"pcdb_id": 16234, "brand_name": "Sime", "model_name": "Murelle EV HE", "model_qualifier": "25", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 56.0, "output_kw_max": 23.9, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016234", "000213", "0", "2018/Mar/05 14:19", "Fonderie Sime S.p.A.", "Sime", "Murelle EV HE", "25", "", "2009", "2018", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "23.9", "23.9", "", "", "88.2", "79.6", "", "56.0", "", "2", "", "", "104", "1", "2", "125", "8", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.5", "97.1", "", "", "", "", "95.5"]} +{"pcdb_id": 16235, "brand_name": "Sime", "model_name": "Murelle EV HE", "model_qualifier": "25", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 80.6, "comparative_hot_water_efficiency_pct": 56.7, "output_kw_max": 23.9, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016235", "000213", "0", "2018/Mar/05 14:20", "Fonderie Sime S.p.A.", "Sime", "Murelle EV HE", "25", "", "2009", "2018", "2", "2", "1", "2", "0", "", "", "2", "3", "2", "23.9", "23.9", "", "", "89.2", "80.6", "", "56.7", "", "2", "1", "", "104", "1", "2", "125", "8", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.4", "99.3", "", "", "", "", "97.6"]} +{"pcdb_id": 16236, "brand_name": "Sime", "model_name": "Murelle EV HE", "model_qualifier": "35 System", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 34.1, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016236", "000213", "0", "2018/Mar/05 16:35", "Fonderie Sime S.p.A.", "Sime", "Murelle EV HE", "35 System", "", "2009", "2018", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "34.1", "34.1", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "140", "8", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.5", "96.2", "", "", "", "", "94.9"]} +{"pcdb_id": 16237, "brand_name": "Sime", "model_name": "Murelle EV HE", "model_qualifier": "35 System", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 34.1, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016237", "000213", "0", "2018/Mar/05 16:36", "Fonderie Sime S.p.A.", "Sime", "Murelle EV HE", "35 System", "", "2009", "2018", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "34.1", "34.1", "", "", "89.0", "80.0", "", "58.4", "", "2", "1", "", "102", "1", "2", "140", "8", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "91.5", "98.4", "", "", "", "", "97.1"]} +{"pcdb_id": 16238, "brand_name": "Sime", "model_name": "Murelle EV HE", "model_qualifier": "30 System", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 28.9, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016238", "000213", "0", "2018/Mar/05 14:25", "Fonderie Sime S.p.A.", "Sime", "Murelle EV HE", "30 System", "", "2009", "2018", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "28.9", "28.9", "", "", "88.2", "79.2", "", "57.9", "", "2", "", "", "102", "1", "2", "130", "8", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.7", "97.0", "", "", "", "", "95.4"]} +{"pcdb_id": 16239, "brand_name": "Sime", "model_name": "Murelle EV HE", "model_qualifier": "30 System", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 28.9, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016239", "000213", "0", "2018/Mar/05 16:32", "Fonderie Sime S.p.A.", "Sime", "Murelle EV HE", "30 System", "", "2009", "2018", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "28.9", "28.9", "", "", "89.2", "80.2", "", "58.6", "", "2", "1", "", "102", "1", "2", "130", "8", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.6", "99.2", "", "", "", "", "97.6"]} +{"pcdb_id": 16240, "brand_name": "Sime", "model_name": "Murelle EV HE", "model_qualifier": "25 System", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 23.9, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016240", "000213", "0", "2018/Mar/05 14:20", "Fonderie Sime S.p.A.", "Sime", "Murelle EV HE", "25 System", "", "2009", "2018", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "23.9", "23.9", "", "", "88.2", "79.2", "", "57.9", "", "2", "", "", "102", "1", "2", "125", "8", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.5", "97.1", "", "", "", "", "95.5"]} +{"pcdb_id": 16241, "brand_name": "Sime", "model_name": "Murelle EV HE", "model_qualifier": "25 System", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 23.9, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016241", "000213", "0", "2018/Mar/05 14:21", "Fonderie Sime S.p.A.", "Sime", "Murelle EV HE", "25 System", "", "2009", "2018", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "23.9", "23.9", "", "", "89.2", "80.2", "", "58.6", "", "2", "1", "", "102", "1", "2", "125", "8", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.4", "99.3", "", "", "", "", "97.6"]} +{"pcdb_id": 16242, "brand_name": "Sime", "model_name": "Murelle EV HE", "model_qualifier": "20 System", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 19.0, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016242", "000213", "0", "2018/Mar/05 14:18", "Fonderie Sime S.p.A.", "Sime", "Murelle EV HE", "20 System", "", "2009", "2018", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "19", "19", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "120", "8", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.2", "96.8", "", "", "", "", "95.1"]} +{"pcdb_id": 16243, "brand_name": "Sime", "model_name": "Murelle EV HE", "model_qualifier": "20 System", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 19.0, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016243", "000213", "0", "2018/Mar/05 14:18", "Fonderie Sime S.p.A.", "Sime", "Murelle EV HE", "20 System", "", "2009", "2018", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "19", "19", "", "", "89.0", "80.0", "", "58.5", "", "2", "1", "", "102", "1", "2", "120", "8", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.2", "98.9", "", "", "", "", "97.3"]} +{"pcdb_id": 16244, "brand_name": "Sime", "model_name": "Murelle EV HE", "model_qualifier": "12 System", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 11.7, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016244", "000213", "0", "2018/Mar/05 14:15", "Fonderie Sime S.p.A.", "Sime", "Murelle EV HE", "12 System", "", "2009", "2018", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "11.7", "11.7", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "110", "8", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.2", "96.6", "", "", "", "", "95.0"]} +{"pcdb_id": 16245, "brand_name": "Sime", "model_name": "Murelle EV HE", "model_qualifier": "12 System", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 11.7, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016245", "000213", "0", "2018/Mar/05 14:16", "Fonderie Sime S.p.A.", "Sime", "Murelle EV HE", "12 System", "", "2009", "2018", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "11.7", "11.7", "", "", "89.0", "80.0", "", "58.4", "", "2", "1", "", "102", "1", "2", "110", "8", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.2", "98.7", "", "", "", "", "97.1"]} +{"pcdb_id": 16246, "brand_name": "Sime", "model_name": "Murelle EV HE", "model_qualifier": "12 T", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 11.7, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016246", "000213", "0", "2018/Mar/05 14:16", "Fonderie Sime S.p.A.", "Sime", "Murelle EV HE", "12 T", "", "2009", "2018", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "11.7", "11.7", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "115", "8", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.2", "96.6", "", "", "", "", "95.0"]} +{"pcdb_id": 16247, "brand_name": "Sime", "model_name": "Murelle EV HE", "model_qualifier": "12 T", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 11.7, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016247", "000213", "0", "2018/Mar/05 14:17", "Fonderie Sime S.p.A.", "Sime", "Murelle EV HE", "12 T", "", "2009", "2018", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "11.7", "11.7", "", "", "89.0", "80.0", "", "58.4", "", "2", "1", "", "102", "1", "2", "115", "8", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.2", "98.7", "", "", "", "", "97.1"]} +{"pcdb_id": 16248, "brand_name": "Sime", "model_name": "Murelle EV HE", "model_qualifier": "20 T", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 19.0, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016248", "000213", "0", "2018/Mar/05 14:17", "Fonderie Sime S.p.A.", "Sime", "Murelle EV HE", "20 T", "", "2009", "2018", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "19.0", "19.0", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "125", "8", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.2", "96.8", "", "", "", "", "95.1"]} +{"pcdb_id": 16249, "brand_name": "Sime", "model_name": "Murelle EV HE", "model_qualifier": "20 T", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 19.0, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016249", "000213", "0", "2018/Mar/05 14:19", "Fonderie Sime S.p.A.", "Sime", "Murelle EV HE", "20 T", "", "2009", "2018", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "19", "19", "", "", "89.0", "80.0", "", "58.5", "", "2", "1", "", "102", "1", "2", "125", "8", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.2", "98.9", "", "", "", "", "97.3"]} +{"pcdb_id": 16250, "brand_name": "Sime", "model_name": "Murelle EV HE", "model_qualifier": "25 T", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 23.9, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016250", "000213", "0", "2018/Mar/05 14:21", "Fonderie Sime S.p.A.", "Sime", "Murelle EV HE", "25 T", "", "2009", "2018", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "23.9", "23.9", "", "", "88.2", "79.2", "", "57.9", "", "2", "", "", "102", "1", "2", "130", "8", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.5", "97.1", "", "", "", "", "95.5"]} +{"pcdb_id": 16251, "brand_name": "Sime", "model_name": "Murelle EV HE", "model_qualifier": "25 T", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 23.9, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016251", "000213", "0", "2018/Mar/05 14:22", "Fonderie Sime S.p.A.", "Sime", "Murelle EV HE", "25 T", "", "2009", "2018", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "23.9", "23.9", "", "", "89.2", "80.2", "", "58.6", "", "2", "1", "", "102", "1", "2", "130", "8", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.4", "99.3", "", "", "", "", "97.6"]} +{"pcdb_id": 16252, "brand_name": "Sime", "model_name": "Murelle EV HE", "model_qualifier": "30 T", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 28.9, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016252", "000213", "0", "2018/Mar/05 16:33", "Fonderie Sime S.p.A.", "Sime", "Murelle EV HE", "30 T", "", "2009", "2018", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "28.9", "28.9", "", "", "88.2", "79.2", "", "57.9", "", "2", "", "", "102", "1", "2", "135", "8", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.7", "97.0", "", "", "", "", "95.4"]} +{"pcdb_id": 16253, "brand_name": "Sime", "model_name": "Murelle EV HE", "model_qualifier": "30 T", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 28.9, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016253", "000213", "0", "2018/Mar/05 16:33", "Fonderie Sime S.p.A.", "Sime", "Murelle EV HE", "30 T", "", "2009", "2018", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "28.9", "28.9", "", "", "89.2", "80.2", "", "58.6", "", "2", "1", "", "102", "1", "2", "135", "8", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.6", "99.2", "", "", "", "", "97.6"]} +{"pcdb_id": 16254, "brand_name": "Sime", "model_name": "Murelle EV HE", "model_qualifier": "35 T", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 34.1, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016254", "000213", "0", "2018/Mar/05 16:36", "Fonderie Sime S.p.A.", "Sime", "Murelle EV HE", "35 T", "", "2009", "2018", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "34.1", "34.1", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "145", "8", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.5", "96.2", "", "", "", "", "94.9"]} +{"pcdb_id": 16255, "brand_name": "Sime", "model_name": "Murelle EV HE", "model_qualifier": "35 T", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 34.1, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016255", "000213", "0", "2018/Mar/05 16:37", "Fonderie Sime S.p.A.", "Sime", "Murelle EV HE", "35 T", "", "2009", "2018", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "34.1", "34.1", "", "", "89.0", "80.0", "", "58.4", "", "2", "1", "", "102", "1", "2", "145", "8", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "91.5", "98.4", "", "", "", "", "97.1"]} +{"pcdb_id": 16256, "brand_name": "Sime", "model_name": "Format DGT HE", "model_qualifier": "25/15", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 55.8, "output_kw_max": 19.5, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016256", "000213", "0", "2018/Feb/28 16:52", "Fonderie Sime S.p.A.", "Sime", "Format DGT HE", "25/15", "", "2009", "2018", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "19.5", "19.5", "", "", "88.0", "79.4", "", "55.8", "", "2", "", "", "104", "1", "2", "125", "8", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "96.9", "", "", "", "", "95.1"]} +{"pcdb_id": 16257, "brand_name": "Sime", "model_name": "Format DGT HE", "model_qualifier": "25/15", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.4, "comparative_hot_water_efficiency_pct": 56.5, "output_kw_max": 19.5, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016257", "000213", "0", "2018/Feb/28 16:53", "Fonderie Sime S.p.A.", "Sime", "Format DGT HE", "25/15", "", "2009", "2018", "2", "2", "1", "2", "0", "", "", "2", "3", "2", "19.5", "19.5", "", "", "89.0", "80.4", "", "56.5", "", "2", "1", "", "104", "1", "2", "125", "8", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.8", "99.0", "", "", "", "", "97.3"]} +{"pcdb_id": 16258, "brand_name": "Sime", "model_name": "Format DGT HE", "model_qualifier": "35", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 56.2, "output_kw_max": 29.4, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016258", "000213", "0", "2018/Feb/28 16:55", "Fonderie Sime S.p.A.", "Sime", "Format DGT HE", "35", "", "2009", "2018", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "29.4", "29.4", "", "", "88.5", "79.9", "", "56.2", "", "2", "", "", "104", "1", "2", "130", "8", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.5", "97.8", "", "", "", "", "96.0"]} +{"pcdb_id": 16259, "brand_name": "Sime", "model_name": "Format DGT HE", "model_qualifier": "35", "winter_efficiency_pct": 89.5, "summer_efficiency_pct": 80.9, "comparative_hot_water_efficiency_pct": 56.9, "output_kw_max": 29.4, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016259", "000213", "0", "2018/Feb/28 16:56", "Fonderie Sime S.p.A.", "Sime", "Format DGT HE", "35", "", "2009", "2018", "2", "2", "1", "2", "0", "", "", "2", "3", "2", "29.4", "29.4", "", "", "89.5", "80.9", "", "56.9", "", "2", "1", "", "104", "1", "2", "130", "8", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.4", "99.9", "", "", "", "", "98.1"]} +{"pcdb_id": 16260, "brand_name": "Sime", "model_name": "Format DGT HE", "model_qualifier": "30", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 56.0, "output_kw_max": 24.6, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016260", "000213", "0", "2018/Feb/28 16:53", "Fonderie Sime S.p.A.", "Sime", "Format DGT HE", "30", "", "2009", "2018", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "24.6", "24.6", "", "", "88.2", "79.6", "", "56.0", "", "2", "", "", "104", "1", "2", "125", "8", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.5", "97.2", "", "", "", "", "95.6"]} +{"pcdb_id": 16261, "brand_name": "Sime", "model_name": "Format DGT HE", "model_qualifier": "30", "winter_efficiency_pct": 89.3, "summer_efficiency_pct": 80.7, "comparative_hot_water_efficiency_pct": 56.7, "output_kw_max": 24.6, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016261", "000213", "0", "2018/Feb/28 16:54", "Fonderie Sime S.p.A.", "Sime", "Format DGT HE", "30", "", "2009", "2018", "2", "2", "1", "2", "0", "", "", "2", "3", "2", "24.6", "24.6", "", "", "89.3", "80.7", "", "56.7", "", "2", "1", "", "104", "1", "2", "125", "8", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.4", "99.4", "", "", "", "", "97.7"]} +{"pcdb_id": 16262, "brand_name": "Sime", "model_name": "Format DGT HE", "model_qualifier": "25", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 55.8, "output_kw_max": 19.5, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016262", "000213", "0", "2018/Feb/28 16:50", "Fonderie Sime S.p.A.", "Sime", "Format DGT HE", "25", "", "2009", "2018", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "19.5", "19.5", "", "", "88.0", "79.4", "", "55.8", "", "2", "", "", "104", "1", "2", "125", "8", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "96.9", "", "", "", "", "95.1"]} +{"pcdb_id": 16263, "brand_name": "Sime", "model_name": "Format DGT HE", "model_qualifier": "25", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.4, "comparative_hot_water_efficiency_pct": 56.5, "output_kw_max": 19.5, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016263", "000213", "0", "2018/Feb/28 16:51", "Fonderie Sime S.p.A.", "Sime", "Format DGT HE", "25", "", "2009", "2018", "2", "2", "1", "2", "0", "", "", "2", "3", "2", "19.5", "19.5", "", "", "89.0", "80.4", "", "56.5", "", "2", "1", "", "104", "1", "2", "125", "8", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.8", "99.0", "", "", "", "", "97.3"]} +{"pcdb_id": 16272, "brand_name": "Fer", "model_name": "tech", "model_qualifier": "18ov", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 17.7, "final_year_of_manufacture": 2017, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016272", "000097", "0", "2017/Aug/21 13:35", "Ferroli", "Fer", "tech", "18ov", "41-267-38", "2009", "2017", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "17.7", "17.7", "", "", "88.7", "79.7", "", "58.2", "", "2", "", "", "102", "1", "2", "50", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.6", "98.3", "", "", "", "", "96.5"]} +{"pcdb_id": 16273, "brand_name": "Fer", "model_name": "tech", "model_qualifier": "18ov", "winter_efficiency_pct": 89.7, "summer_efficiency_pct": 80.7, "comparative_hot_water_efficiency_pct": 58.9, "output_kw_max": 17.7, "final_year_of_manufacture": 2017, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016273", "000097", "0", "2017/Aug/21 13:44", "Ferroli", "Fer", "tech", "18ov", "", "2009", "2017", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "17.7", "17.7", "", "", "89.7", "80.7", "", "58.9", "", "2", "1", "", "102", "1", "2", "50", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.5", "100.5", "", "", "", "", "98.6"]} +{"pcdb_id": 16274, "brand_name": "Fer", "model_name": "tech", "model_qualifier": "25ov", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 24.6, "final_year_of_manufacture": 2017, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016274", "000097", "0", "2017/Aug/21 13:36", "Ferroli", "Fer", "tech", "25ov", "41-267-39", "2009", "2017", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24.6", "24.6", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "50", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.6", "97.6", "", "", "", "", "95.9"]} +{"pcdb_id": 16275, "brand_name": "Fer", "model_name": "tech", "model_qualifier": "25ov", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 80.4, "comparative_hot_water_efficiency_pct": 58.7, "output_kw_max": 24.6, "final_year_of_manufacture": 2017, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016275", "000097", "0", "2017/Aug/21 13:43", "Ferroli", "Fer", "tech", "25ov", "", "2009", "2017", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "24.6", "24.6", "", "", "89.4", "80.4", "", "58.7", "", "2", "1", "", "102", "1", "2", "50", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.5", "99.7", "", "", "", "", "98.0"]} +{"pcdb_id": 16276, "brand_name": "Fer", "model_name": "tech", "model_qualifier": "31C", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 56.1, "output_kw_max": 24.6, "final_year_of_manufacture": 2017, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016276", "000097", "0", "2017/Aug/21 13:36", "Ferroli", "Fer", "tech", "31C", "47-267-51", "2009", "2017", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.6", "24.6", "", "", "88.4", "79.8", "", "56.1", "", "2", "", "", "104", "1", "2", "130", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "", "", "0005", "", "", "", "", "", "", "", "", "88.6", "97.6", "", "", "", "", "95.9"]} +{"pcdb_id": 16277, "brand_name": "Fer", "model_name": "tech", "model_qualifier": "31C", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 56.8, "output_kw_max": 24.6, "final_year_of_manufacture": 2017, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016277", "000097", "0", "2017/Aug/21 13:38", "Ferroli", "Fer", "tech", "31C", "", "2009", "2017", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24.6", "24.6", "", "", "89.4", "80.8", "", "56.8", "", "2", "1", "", "104", "1", "2", "130", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "", "", "0005", "", "", "", "", "", "", "", "", "90.5", "99.7", "", "", "", "", "98.0"]} +{"pcdb_id": 16278, "brand_name": "Fer", "model_name": "tech", "model_qualifier": "38C", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 56.3, "output_kw_max": 30.2, "final_year_of_manufacture": 2017, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016278", "000097", "0", "2017/Aug/21 13:36", "Ferroli", "Fer", "tech", "38C", "47-267-52", "2009", "2017", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "30.2", "30.2", "", "", "88.7", "80.1", "", "56.3", "", "2", "", "", "104", "1", "2", "140", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "", "", "0005", "", "", "", "", "", "", "", "", "88.7", "98.3", "", "", "", "", "96.5"]} +{"pcdb_id": 16279, "brand_name": "Fer", "model_name": "tech", "model_qualifier": "38C", "winter_efficiency_pct": 89.7, "summer_efficiency_pct": 81.1, "comparative_hot_water_efficiency_pct": 57.1, "output_kw_max": 30.2, "final_year_of_manufacture": 2017, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016279", "000097", "0", "2017/Aug/21 13:38", "Ferroli", "Fer", "tech", "38C", "", "2009", "2017", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "30.2", "30.2", "", "", "89.7", "81.1", "", "57.1", "", "2", "1", "", "104", "1", "2", "140", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "", "", "0005", "", "", "", "", "", "", "", "", "90.7", "100.5", "", "", "", "", "98.6"]} +{"pcdb_id": 16281, "brand_name": "Remeha", "model_name": "Avanta", "model_qualifier": "12 V", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 12.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016281", "000005", "0", "2012/Apr/11 14:49", "Remeha", "Remeha", "Avanta", "12 V", "41-288-09", "2009", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "12", "12", "", "", "88.1", "79.1", "", "57.8", "", "2", "", "", "102", "1", "2", "50", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.1", "97.0", "", "", "", "", "95.3"]} +{"pcdb_id": 16282, "brand_name": "Remeha", "model_name": "Avanta", "model_qualifier": "28 ECO", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 62.4, "output_kw_max": 21.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016282", "000006", "0", "2009/Dec/08 15:34", "Remeha", "Remeha", "Avanta", "28 ECO", "47-288-02", "2009", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "21.6", "21.6", "", "", "88.5", "79.9", "", "62.4", "", "2", "", "", "104", "1", "2", "115", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "3", "1", "", "0005", "", "", "", "", "", "", "", "", "88.6", "97.9", "", "", "", "", "96.2"]} +{"pcdb_id": 16283, "brand_name": "Remeha", "model_name": "Avanta", "model_qualifier": "30 V", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 29.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016283", "000005", "0", "2012/Apr/11 14:49", "Remeha", "Remeha", "Avanta", "30 V", "41-288-14", "2009", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "29.4", "29.4", "", "", "88.2", "79.2", "", "57.9", "", "2", "", "", "102", "1", "2", "115", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.5", "97.1", "", "", "", "", "95.5"]} +{"pcdb_id": 16284, "brand_name": "Remeha", "model_name": "Avanta Plus", "model_qualifier": "18S", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 18.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016284", "000005", "0", "2012/Apr/11 14:49", "Remeha", "Remeha", "Avanta Plus", "18S", "41-288-11", "2008", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18", "18", "", "", "88.1", "79.1", "", "57.8", "", "2", "", "", "102", "1", "2", "115", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.1", "97.0", "", "", "", "", "95.3"]} +{"pcdb_id": 16285, "brand_name": "Remeha", "model_name": "Avanta", "model_qualifier": "15v", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 15.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016285", "000005", "0", "2012/Apr/11 14:49", "Remeha", "Remeha", "Avanta", "15v", "41-288-13", "2009", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "15", "15", "", "", "88.2", "79.2", "", "57.8", "", "2", "", "", "102", "1", "2", "50", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.4", "97.0", "", "", "", "", "95.4"]} +{"pcdb_id": 16286, "brand_name": "Remeha", "model_name": "Avanta Plus", "model_qualifier": "24 C", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 55.9, "output_kw_max": 20.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016286", "000005", "0", "2012/Apr/11 14:49", "Remeha", "Remeha", "Avanta Plus", "24 C", "47-288-01", "2008", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "20.0", "20.0", "", "", "88.1", "79.5", "", "55.9", "", "2", "", "", "104", "1", "2", "115", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "0", "", "0005", "", "", "", "", "", "", "", "", "88.1", "97.0", "", "", "", "", "95.3"]} +{"pcdb_id": 16287, "brand_name": "Remeha", "model_name": "Avanta Plus", "model_qualifier": "30 S", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 29.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016287", "000005", "0", "2012/Apr/11 14:49", "Remeha", "Remeha", "Avanta Plus", "30 S", "41-288-12", "2008", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "29.4", "29.4", "", "", "88.2", "79.2", "", "57.9", "", "2", "", "", "102", "1", "2", "150", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.5", "97.1", "", "", "", "", "95.5"]} +{"pcdb_id": 16289, "brand_name": "Remeha", "model_name": "Avanta", "model_qualifier": "24 V", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 24.7, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016289", "000005", "0", "2012/Apr/11 14:49", "Remeha", "Remeha", "Avanta", "24 V", "41-288-10", "2008", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24.7", "24.7", "", "", "88.2", "79.2", "", "57.8", "", "2", "", "", "102", "1", "2", "50", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.2", "97.1", "", "", "", "", "95.4"]} +{"pcdb_id": 16291, "brand_name": "Ferroli", "model_name": "DOMIcondens", "model_qualifier": "F24", "winter_efficiency_pct": 86.4, "summer_efficiency_pct": 77.8, "comparative_hot_water_efficiency_pct": 54.7, "output_kw_max": 24.1, "final_year_of_manufacture": 2017, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016291", "000097", "0", "2017/Aug/21 13:37", "Ferroli", "Ferroli", "DOMIcondens", "F24", "", "2009", "2017", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.1", "24.1", "", "", "86.4", "77.8", "", "54.7", "", "2", "", "", "104", "1", "2", "135", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "86.9", "93.3", "", "", "", "", "92.1"]} +{"pcdb_id": 16292, "brand_name": "Ferroli", "model_name": "DOMIcondens", "model_qualifier": "F24", "winter_efficiency_pct": 87.4, "summer_efficiency_pct": 78.8, "comparative_hot_water_efficiency_pct": 55.4, "output_kw_max": 24.1, "final_year_of_manufacture": 2017, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016292", "000097", "0", "2017/Aug/21 13:38", "Ferroli", "Ferroli", "DOMIcondens", "F24", "", "2009", "2017", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24.1", "24.1", "", "", "87.4", "78.8", "", "55.4", "", "2", "1", "", "104", "1", "2", "135", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.9", "95.3", "", "", "", "", "94.1"]} +{"pcdb_id": 16294, "brand_name": "Keston", "model_name": "Q37", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 33.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016294", "000022", "0", "2012/Mar/27 10:12", "Keston Boilers", "Keston", "Q37", "", "", "2010", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "33.6", "33.6", "", "", "88.6", "79.6", "", "58.1", "", "2", "", "", "102", "1", "2", "198", "4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.4", "98.1", "", "", "", "", "96.3"]} +{"pcdb_id": 16295, "brand_name": "Keston", "model_name": "Q37P", "model_qualifier": "", "winter_efficiency_pct": 89.6, "summer_efficiency_pct": 80.6, "comparative_hot_water_efficiency_pct": 58.9, "output_kw_max": 33.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016295", "000022", "0", "2012/Mar/27 10:12", "Keston Boilers", "Keston", "Q37P", "", "", "2010", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "33.6", "33.6", "", "", "89.6", "80.6", "", "58.9", "", "2", "1", "", "102", "1", "2", "198", "4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.4", "100.3", "", "", "", "", "98.4"]} +{"pcdb_id": 16296, "brand_name": "ARCA", "model_name": "PIXELfast 25 FC", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 56.2, "output_kw_max": 24.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016296", "000261", "0", "2010/Jan/28 12:31", "ARCA", "ARCA", "PIXELfast 25 FC", "", "", "2008", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.4", "24.4", "", "", "88.5", "79.9", "", "56.2", "", "2", "", "", "104", "1", "2", "150", "5", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "97.9", "", "", "", "", "96.1"]} +{"pcdb_id": 16297, "brand_name": "ARCA", "model_name": "PIXELfast 25FCR", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 24.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016297", "000261", "0", "2012/Mar/27 10:12", "ARCA", "ARCA", "PIXELfast 25FCR", "", "", "2008", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24.4", "24.4", "", "", "88.5", "79.5", "", "58.0", "", "2", "", "", "102", "1", "2", "150", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "97.9", "", "", "", "", "96.1"]} +{"pcdb_id": 16298, "brand_name": "ARCA", "model_name": "PIXELfast 31 FC", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 56.2, "output_kw_max": 30.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016298", "000261", "0", "2010/Jan/28 12:31", "ARCA", "ARCA", "PIXELfast 31 FC", "", "", "2008", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "30.2", "30.2", "", "", "88.5", "79.9", "", "56.2", "", "2", "", "", "104", "1", "2", "150", "5", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "97.9", "", "", "", "", "96.1"]} +{"pcdb_id": 16299, "brand_name": "ARCA", "model_name": "PIXELfast 31 FCR", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 30.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016299", "000261", "0", "2012/Mar/27 10:12", "ARCA", "ARCA", "PIXELfast 31 FCR", "", "", "2008", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "30.2", "30.2", "", "", "88.5", "79.5", "", "58.0", "", "2", "", "", "102", "1", "2", "150", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "97.9", "", "", "", "", "96.1"]} +{"pcdb_id": 16300, "brand_name": "ARCA", "model_name": "PIXELfast 26 FCX", "model_qualifier": "", "winter_efficiency_pct": 87.4, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 56.4, "output_kw_max": 25.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016300", "000261", "0", "2012/Jul/03 16:27", "ARCA", "ARCA", "PIXELfast 26 FCX", "", "", "2007", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "25.4", "25.4", "", "", "87.4", "80.2", "", "56.4", "", "2", "", "", "103", "1", "1", "150", "5", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "88.7", "98.6", "", "", "", "", "96.7"]} +{"pcdb_id": 16301, "brand_name": "ARCA", "model_name": "PIXELfast 26 FCXR", "model_qualifier": "", "winter_efficiency_pct": 87.4, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 25.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016301", "000261", "0", "2012/Jul/03 16:27", "ARCA", "ARCA", "PIXELfast 26 FCXR", "", "", "2007", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "25.4", "25.4", "", "", "87.4", "79.8", "", "58.3", "", "2", "", "", "101", "1", "1", "150", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "88.7", "98.6", "", "", "", "", "96.7"]} +{"pcdb_id": 16302, "brand_name": "ARCA", "model_name": "PIXELfast B 26 FCX", "model_qualifier": "", "winter_efficiency_pct": 87.4, "summer_efficiency_pct": 81.5, "comparative_hot_water_efficiency_pct": 78.7, "output_kw_max": 25.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016302", "000261", "0", "2024/Jan/31 10:17", "ARCA", "ARCA", "PIXELfast B 26 FCX", "", "", "2007", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "25.4", "25.4", "", "", "87.4", "81.5", "", "78.7", "", "2", "", "", "105", "1", "1", "150", "5", "0", "1", "", "50", "0", "11", "2", "60", "62", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "88.7", "98.6", "", "", "", "", "96.7"]} +{"pcdb_id": 16303, "brand_name": "ARCA", "model_name": "PIXELfast 120/25 FC", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 56.2, "output_kw_max": 24.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016303", "000261", "0", "2010/Jan/28 12:30", "ARCA", "ARCA", "PIXELfast 120/25 FC", "", "", "2009", "current", "1", "1", "1", "2", "0", "", "", "2", "2", "2", "24.4", "24.4", "", "", "88.5", "79.9", "", "56.2", "", "2", "", "", "104", "1", "2", "150", "5", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "97.9", "", "", "", "", "96.1"]} +{"pcdb_id": 16304, "brand_name": "ARCA", "model_name": "PIXELfast 120/26 FCX", "model_qualifier": "", "winter_efficiency_pct": 87.4, "summer_efficiency_pct": 81.5, "comparative_hot_water_efficiency_pct": 81.5, "output_kw_max": 25.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016304", "000261", "0", "2024/Jan/31 10:17", "ARCA", "ARCA", "PIXELfast 120/26 FCX", "", "", "2009", "current", "1", "1", "1", "2", "0", "", "", "2", "2", "2", "25.4", "25.4", "", "", "87.4", "81.5", "", "81.5", "", "2", "", "", "105", "1", "1", "150", "5", "0", "1", "", "100", "0", "18", "2", "60", "86", "0", "", "", "", "", "", "", "", "", "", "0", "0", "", "0003", "", "", "", "", "", "", "", "", "88.7", "98.6", "", "", "", "", "96.7"]} +{"pcdb_id": 16305, "brand_name": "ARCA", "model_name": "PIXELfast 120/31 FC", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 56.2, "output_kw_max": 30.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016305", "000261", "0", "2010/Jan/28 12:30", "ARCA", "ARCA", "PIXELfast 120/31 FC", "", "", "2009", "current", "1", "1", "1", "2", "0", "", "", "2", "2", "2", "30.2", "30.2", "", "", "88.5", "79.9", "", "56.2", "", "2", "", "", "104", "1", "2", "150", "5", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "97.9", "", "", "", "", "96.1"]} +{"pcdb_id": 16306, "brand_name": "ARCA", "model_name": "PIXELfast 26 FCX Sun", "model_qualifier": "", "winter_efficiency_pct": 87.4, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 56.4, "output_kw_max": 25.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016306", "000261", "0", "2012/Jul/03 16:28", "ARCA", "ARCA", "PIXELfast 26 FCX Sun", "", "", "2008", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "25.4", "25.4", "", "", "87.4", "80.2", "", "56.4", "", "2", "", "", "103", "1", "1", "150", "5", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "88.7", "98.6", "", "", "", "", "96.7"]} +{"pcdb_id": 16307, "brand_name": "ARCA", "model_name": "PIXELfast 31 FC Sun", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 56.2, "output_kw_max": 30.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016307", "000261", "0", "2010/Jan/28 12:30", "ARCA", "ARCA", "PIXELfast 31 FC Sun", "", "", "2005", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "30.2", "30.2", "", "", "88.5", "79.9", "", "56.2", "", "2", "", "", "104", "1", "2", "150", "5", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "97.9", "", "", "", "", "96.1"]} +{"pcdb_id": 16308, "brand_name": "ARCA", "model_name": "PIXELfast 25 FC Sun", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 56.2, "output_kw_max": 24.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016308", "000261", "0", "2010/Jan/28 12:29", "ARCA", "ARCA", "PIXELfast 25 FC Sun", "", "", "2008", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.4", "24.4", "", "", "88.5", "79.9", "", "56.2", "", "2", "", "", "104", "1", "2", "150", "5", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "97.9", "", "", "", "", "96.1"]} +{"pcdb_id": 16311, "brand_name": "Termet", "model_name": "Ecocondens Plus", "model_qualifier": "25", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 22.9, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016311", "000262", "0", "2012/Mar/27 10:12", "Termet", "Termet", "Ecocondens Plus", "25", "", "2009", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "22.9", "22.9", "", "", "88.1", "79.1", "", "57.8", "", "2", "", "", "102", "1", "2", "200", "8", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "97.2", "", "", "", "", "95.4"]} +{"pcdb_id": 16312, "brand_name": "Termet", "model_name": "Ecocondens Plus", "model_qualifier": "25 combi", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 55.9, "output_kw_max": 22.9, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016312", "000262", "0", "2010/Feb/08 15:42", "Termet", "Termet", "Ecocondens Plus", "25 combi", "", "2009", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "22.9", "22.9", "", "", "88.1", "79.5", "", "55.9", "", "2", "", "", "104", "1", "2", "200", "8", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "97.2", "", "", "", "", "95.4"]} +{"pcdb_id": 16313, "brand_name": "Termet", "model_name": "Ecocondens Plus", "model_qualifier": "30", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 28.8, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016313", "000262", "0", "2012/Mar/27 10:12", "Termet", "Termet", "Ecocondens Plus", "30", "", "2009", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "28.8", "28.8", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "200", "8", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "96.9", "", "", "", "", "95.1"]} +{"pcdb_id": 16314, "brand_name": "Termet", "model_name": "Ecocondens Plus", "model_qualifier": "30 combi", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 55.8, "output_kw_max": 28.8, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016314", "000262", "0", "2013/Feb/21 14:42", "Termet", "Termet", "Ecocondens Plus", "30 combi", "", "2009", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28.8", "28.8", "", "", "88.0", "79.4", "", "55.8", "", "2", "", "", "104", "1", "2", "200", "8", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "96.9", "", "", "", "", "95.1"]} +{"pcdb_id": 16315, "brand_name": "Termet", "model_name": "Ecocondens Plus", "model_qualifier": "50", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 45.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016315", "000262", "0", "2012/Mar/27 10:12", "Termet", "Termet", "Ecocondens Plus", "50", "", "2009", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "45.3", "45.3", "", "", "88.1", "79.1", "", "57.7", "", "2", "", "", "102", "1", "2", "200", "8", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "97.0", "", "", "", "", "95.3"]} +{"pcdb_id": 16316, "brand_name": "Termet", "model_name": "Windsor Plus", "model_qualifier": "25", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 22.9, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016316", "000262", "0", "2012/Mar/27 10:12", "Termet", "Termet", "Windsor Plus", "25", "", "2009", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "22.9", "22.9", "", "", "88.1", "79.1", "", "57.8", "", "2", "", "", "102", "1", "2", "200", "8", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "97.2", "", "", "", "", "95.4"]} +{"pcdb_id": 16317, "brand_name": "Termet", "model_name": "Windsor Plus", "model_qualifier": "25 combi", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 55.9, "output_kw_max": 22.9, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016317", "000262", "0", "2010/Feb/08 15:42", "Termet", "Termet", "Windsor Plus", "25 combi", "", "2009", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "22.9", "22.9", "", "", "88.1", "79.5", "", "55.9", "", "2", "", "", "104", "1", "2", "200", "8", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "97.2", "", "", "", "", "95.4"]} +{"pcdb_id": 16318, "brand_name": "Termet", "model_name": "Windsor Plus", "model_qualifier": "30", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 28.8, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016318", "000262", "0", "2012/Mar/27 10:12", "Termet", "Termet", "Windsor Plus", "30", "", "2009", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "28.8", "28.8", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "200", "8", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "96.9", "", "", "", "", "95.1"]} +{"pcdb_id": 16319, "brand_name": "Termet", "model_name": "Windsor Plus", "model_qualifier": "30 combi", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 55.8, "output_kw_max": 28.8, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016319", "000262", "0", "2010/Feb/08 15:42", "Termet", "Termet", "Windsor Plus", "30 combi", "", "2009", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28.8", "28.8", "", "", "88.0", "79.4", "", "55.8", "", "2", "", "", "104", "1", "2", "200", "8", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "96.9", "", "", "", "", "95.1"]} +{"pcdb_id": 16320, "brand_name": "Termet", "model_name": "Windsor Plus", "model_qualifier": "50", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 45.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016320", "000262", "0", "2012/Mar/27 10:12", "Termet", "Termet", "Windsor Plus", "50", "", "2009", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "45.3", "45.3", "", "", "88.1", "79.1", "", "57.7", "", "2", "", "", "102", "1", "2", "200", "8", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "97.0", "", "", "", "", "95.3"]} +{"pcdb_id": 16321, "brand_name": "Glow-worm", "model_name": "Ultracom 2 12sxi", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 12.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016321", "000207", "0", "2012/Mar/27 10:12", "Vaillant Group UK", "Glow-worm", "Ultracom 2 12sxi", "", "G.C.No.41-019-12", "2010", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "12.0", "12.0", "", "", "88.8", "79.8", "", "58.3", "", "2", "", "", "102", "1", "2", "151", "6", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0085", "", "", "", "", "", "", "", "", "88.5", "98.7", "", "", "", "", "96.7"]} +{"pcdb_id": 16323, "brand_name": "Glow-worm", "model_name": "Ultracom 2 18sxi", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 18.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016323", "000207", "0", "2012/Mar/27 10:12", "Vaillant Group UK", "Glow-worm", "Ultracom 2 18sxi", "", "G.C.No.41-019-13", "2010", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18.2", "18.2", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "151", "6", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0085", "", "", "", "", "", "", "", "", "88.5", "97.7", "", "", "", "", "95.9"]} +{"pcdb_id": 16324, "brand_name": "Glow-worm", "model_name": "Ultracom 2 18sxi", "model_qualifier": "", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 80.4, "comparative_hot_water_efficiency_pct": 58.8, "output_kw_max": 18.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016324", "000207", "0", "2012/Mar/27 10:12", "Vaillant Group UK", "Glow-worm", "Ultracom 2 18sxi", "", "", "2010", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "18.2", "18.2", "", "", "89.4", "80.4", "", "58.8", "", "2", "1", "", "102", "1", "2", "151", "6", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.4", "99.8", "", "", "", "", "98.1"]} +{"pcdb_id": 16325, "brand_name": "Glow-worm", "model_name": "Ultracom 2 24cxi", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 86.8, "comparative_hot_water_efficiency_pct": 73.9, "output_kw_max": 18.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0002, "loss_factor_f1_kwh_per_day": 1.02333, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016325", "000207", "0", "2012/Jul/20 11:52", "Vaillant Group UK", "Glow-worm", "Ultracom 2 24cxi", "", "G.C.No.41-019-10", "2010", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "18.2", "18.2", "", "", "88.4", "86.8", "", "73.9", "", "2", "", "", "104", "1", "2", "151", "6", "0", "", "", "0", "0", "", "", "", "", "1", "7.127", "0.111", "0.0002", "1.02333", "", "", "", "", "", "", "", "", "0085", "", "", "", "", "", "", "", "", "88.5", "97.7", "", "", "", "", "95.9"]} +{"pcdb_id": 16326, "brand_name": "Glow-worm", "model_name": "Ultracom 2 24cxi", "model_qualifier": "", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 56.8, "output_kw_max": 18.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016326", "000207", "0", "2010/May/27 08:28", "Vaillant Group UK", "Glow-worm", "Ultracom 2 24cxi", "", "", "2010", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "18.2", "18.2", "", "", "89.4", "80.8", "", "56.8", "", "2", "1", "", "104", "1", "2", "151", "6", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.4", "99.8", "", "", "", "", "98.1"]} +{"pcdb_id": 16327, "brand_name": "Glow-worm", "model_name": "Ultracom 2 30cxi", "model_qualifier": "", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 86.8, "comparative_hot_water_efficiency_pct": 73.6, "output_kw_max": 24.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0007, "loss_factor_f1_kwh_per_day": 1.04421, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016327", "000207", "0", "2012/Jul/20 11:55", "Vaillant Group UK", "Glow-worm", "Ultracom 2 30cxi", "", "G.C.No.47-019-11", "2010", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.6", "24.6", "", "", "88.7", "86.8", "", "73.6", "", "2", "", "", "104", "1", "2", "151", "6", "0", "", "", "0", "0", "", "", "", "", "1", "7.152", "0.11", "0.0007", "1.04421", "", "", "", "", "", "", "", "", "0085", "", "", "", "", "", "", "", "", "88.5", "98.4", "", "", "", "", "96.5"]} +{"pcdb_id": 16328, "brand_name": "Glow-worm", "model_name": "Ultracom 2 30cxi", "model_qualifier": "", "winter_efficiency_pct": 89.7, "summer_efficiency_pct": 81.1, "comparative_hot_water_efficiency_pct": 57.0, "output_kw_max": 24.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016328", "000207", "0", "2010/May/26 07:53", "Vaillant Group UK", "Glow-worm", "Ultracom 2 30cxi", "", "G.C.No.47-019-11", "2010", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24.6", "24.6", "", "", "89.7", "81.1", "", "57.0", "", "2", "1", "", "104", "1", "2", "151", "6", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.4", "100.6", "", "", "", "", "98.6"]} +{"pcdb_id": 16331, "brand_name": "Lamborghini Caloreclima", "model_name": "Extrema", "model_qualifier": "30 C", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 56.2, "output_kw_max": 24.6, "final_year_of_manufacture": 2017, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016331", "000097", "0", "2017/Aug/21 13:37", "Ferroli", "Lamborghini Caloreclima", "Extrema", "30 C", "", "2009", "2017", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.6", "24.6", "", "", "88.5", "79.9", "", "56.2", "", "2", "", "", "104", "1", "2", "130", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "98.2", "", "", "", "", "96.3"]} +{"pcdb_id": 16332, "brand_name": "Lamborghini Caloreclima", "model_name": "Extrema", "model_qualifier": "30 C", "winter_efficiency_pct": 89.6, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 56.9, "output_kw_max": 24.6, "final_year_of_manufacture": 2017, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016332", "000097", "0", "2017/Aug/21 13:39", "Ferroli", "Lamborghini Caloreclima", "Extrema", "30 C", "", "2009", "2017", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24.6", "24.6", "", "", "89.6", "81.0", "", "56.9", "", "2", "1", "", "104", "1", "2", "130", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "", "", "0005", "", "", "", "", "", "", "", "", "89.9", "100.4", "", "", "", "", "98.4"]} +{"pcdb_id": 16333, "brand_name": "Lamborghini Caloreclima", "model_name": "Extrema", "model_qualifier": "38 C", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 56.2, "output_kw_max": 31.4, "final_year_of_manufacture": 2017, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016333", "000097", "0", "2017/Aug/21 13:37", "Ferroli", "Lamborghini Caloreclima", "Extrema", "38 C", "", "2009", "2017", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "31.4", "31.4", "", "", "88.5", "79.9", "", "56.2", "", "2", "", "", "104", "1", "2", "150", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "98.2", "", "", "", "", "96.3"]} +{"pcdb_id": 16335, "brand_name": "Lamborghini Caloreclima", "model_name": "Extrema", "model_qualifier": "38 C", "winter_efficiency_pct": 89.6, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 56.9, "output_kw_max": 31.4, "final_year_of_manufacture": 2017, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016335", "000097", "0", "2017/Aug/21 13:41", "Ferroli", "Lamborghini Caloreclima", "Extrema", "38 C", "", "2009", "2017", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "31.4", "31.4", "", "", "89.6", "81.0", "", "56.9", "", "2", "1", "", "104", "1", "2", "150", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "", "", "0005", "", "", "", "", "", "", "", "", "89.9", "100.4", "", "", "", "", "98.4"]} +{"pcdb_id": 16348, "brand_name": "ATAG", "model_name": "A325C", "model_qualifier": "X", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 56.6, "output_kw_max": 28.8, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016348", "000227", "0", "2013/Oct/23 12:58", "ATAG Verwarming Nederland BV", "ATAG", "A325C", "X", "", "2010", "current", "1", "3", "1", "2", "0", "", "", "2", "3", "2", "28.8", "28.8", "", "", "89.1", "80.5", "", "56.6", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.8", "98.8", "", "", "", "", "97.1"]} +{"pcdb_id": 16349, "brand_name": "ATAG", "model_name": "A320S", "model_qualifier": "X", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 28.8, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016349", "000227", "0", "2013/Oct/23 12:58", "ATAG Verwarming Nederland BV", "ATAG", "A320S", "X", "", "2010", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "28.8", "28.8", "", "", "89.1", "80.1", "", "58.5", "", "2", "", "", "102", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.8", "98.8", "", "", "", "", "97.1"]} +{"pcdb_id": 16353, "brand_name": "ATAG", "model_name": "A325EC", "model_qualifier": "X", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 85.2, "output_kw_max": 28.8, "final_year_of_manufacture": null, "subsidiary_type": 1, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0008, "loss_factor_f1_kwh_per_day": 0.13684, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016353", "000227", "3", "2021/Nov/29 20:19", "ATAG Verwarming Nederland BV", "ATAG", "A325EC", "X", "", "2010", "current", "1", "2", "1", "2", "1", "313", "060023", "2", "3", "2", "28.8", "28.8", "", "", "89.1", "87.3", "", "85.2", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "", "0", "", "", "", "", "1", "6.18", "0.178", "0.0008", "0.13684", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.8", "98.8", "", "", "", "", "97.1"]} +{"pcdb_id": 16356, "brand_name": "Unical", "model_name": "Alkon R 18 HE", "model_qualifier": "", "winter_efficiency_pct": 87.7, "summer_efficiency_pct": 78.7, "comparative_hot_water_efficiency_pct": 57.5, "output_kw_max": 17.7, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016356", "000263", "0", "2012/Mar/27 10:12", "Unical AG", "Unical", "Alkon R 18 HE", "", "", "2010", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "17.7", "17.7", "", "", "87.7", "78.7", "", "57.5", "", "2", "", "", "102", "1", "2", "132", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.6", "95.9", "", "", "", "", "94.5"]} +{"pcdb_id": 16357, "brand_name": "Unical", "model_name": "Alkon C 18 HE", "model_qualifier": "", "winter_efficiency_pct": 87.7, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 55.6, "output_kw_max": 17.7, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016357", "000263", "0", "2010/May/27 11:09", "Unical AG", "Unical", "Alkon C 18 HE", "", "", "2010", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "17.7", "17.7", "", "", "87.7", "79.1", "", "55.6", "", "2", "", "", "104", "1", "2", "132", "5", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.6", "95.9", "", "", "", "", "94.5"]} +{"pcdb_id": 16358, "brand_name": "Unical", "model_name": "Alkon C 24 HE", "model_qualifier": "", "winter_efficiency_pct": 87.8, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 55.7, "output_kw_max": 23.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016358", "000263", "0", "2010/May/27 11:09", "Unical AG", "Unical", "Alkon C 24 HE", "", "", "2010", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "23.3", "23.3", "", "", "87.8", "79.2", "", "55.7", "", "2", "", "", "104", "1", "2", "132", "5", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "96.3", "", "", "", "", "94.7"]} +{"pcdb_id": 16359, "brand_name": "Unical", "model_name": "Alkon R 24 HE", "model_qualifier": "", "winter_efficiency_pct": 87.8, "summer_efficiency_pct": 78.8, "comparative_hot_water_efficiency_pct": 57.6, "output_kw_max": 23.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016359", "000263", "0", "2012/Mar/27 10:12", "Unical AG", "Unical", "Alkon R 24 HE", "", "", "2010", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "23.3", "23.3", "", "", "87.8", "78.8", "", "57.6", "", "2", "", "", "102", "1", "2", "132", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "96.3", "", "", "", "", "94.7"]} +{"pcdb_id": 16360, "brand_name": "Unical", "model_name": "Alkon 28 SR HE", "model_qualifier": "", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 78.9, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 27.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016360", "000263", "0", "2012/Mar/27 10:12", "Unical AG", "Unical", "Alkon 28 SR HE", "", "", "2010", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "27.3", "27.3", "", "", "87.9", "78.9", "", "57.7", "", "2", "", "", "102", "1", "2", "130", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "96.7", "", "", "", "", "95.0"]} +{"pcdb_id": 16361, "brand_name": "Unical", "model_name": "Alkon 28 SC HE", "model_qualifier": "", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 55.8, "output_kw_max": 27.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016361", "000263", "0", "2010/May/27 11:11", "Unical AG", "Unical", "Alkon 28 SC HE", "", "", "2010", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "27.3", "27.3", "", "", "87.9", "79.3", "", "55.8", "", "2", "", "", "104", "1", "2", "130", "5", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "96.7", "", "", "", "", "95.0"]} +{"pcdb_id": 16362, "brand_name": "Unical", "model_name": "Alkon Slim 28 HE", "model_qualifier": "", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 56.0, "output_kw_max": 27.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016362", "000263", "0", "2010/May/27 11:08", "Unical AG", "Unical", "Alkon Slim 28 HE", "", "", "2010", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "27.5", "27.5", "", "", "88.2", "79.6", "", "56.0", "", "2", "", "", "104", "1", "2", "163", "5", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.4", "97.1", "", "", "", "", "95.5"]} +{"pcdb_id": 16363, "brand_name": "Unical", "model_name": "Alkon Slim 35 HE", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 55.9, "output_kw_max": 33.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016363", "000263", "0", "2010/May/27 11:08", "Unical AG", "Unical", "Alkon Slim 35 HE", "", "", "2010", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "33.3", "33.3", "", "", "88.1", "79.5", "", "55.9", "", "2", "", "", "104", "1", "2", "163", "5", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "96.9", "", "", "", "", "95.2"]} +{"pcdb_id": 16364, "brand_name": "Glow-worm", "model_name": "Ultracom 2 30sxi", "model_qualifier": "", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 30.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016364", "000207", "0", "2013/Jan/30 14:46", "Vaillant Group UK", "Glow-worm", "Ultracom 2 30sxi", "", "G.C.No.41-019-14", "2010", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "30.0", "30.0", "", "", "88.7", "79.7", "", "58.2", "", "2", "", "", "102", "1", "2", "151", "6", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0085", "", "", "", "", "", "", "", "", "88.6", "98.4", "", "", "", "", "96.5"]} +{"pcdb_id": 16365, "brand_name": "Glow-worm", "model_name": "Ultracom 2 30sxi", "model_qualifier": "", "winter_efficiency_pct": 89.7, "summer_efficiency_pct": 80.7, "comparative_hot_water_efficiency_pct": 59.0, "output_kw_max": 30.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016365", "000207", "0", "2013/Jan/30 14:46", "Vaillant Group UK", "Glow-worm", "Ultracom 2 30sxi", "", "G.C.No.41-019-14", "2010", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "30.0", "30.0", "", "", "89.7", "80.7", "", "59.0", "", "2", "1", "", "102", "1", "2", "151", "6", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.5", "100.6", "", "", "", "", "98.7"]} +{"pcdb_id": 16366, "brand_name": "Glow-worm", "model_name": "Ultracom 2 35cxi", "model_qualifier": "", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 86.9, "comparative_hot_water_efficiency_pct": 72.2, "output_kw_max": 30.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0006, "loss_factor_f1_kwh_per_day": 1.18145, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016366", "000207", "0", "2013/Jan/30 14:47", "Vaillant Group UK", "Glow-worm", "Ultracom 2 35cxi", "", "G.C.No.47-019-12", "2010", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "30.0", "30.0", "", "", "88.7", "86.9", "", "72.2", "", "2", "", "", "104", "1", "2", "151", "6", "0", "", "", "0", "0", "", "", "", "", "1", "7.291", "0.109", "0.0006", "1.18145", "", "", "", "", "", "", "", "", "0085", "", "", "", "", "", "", "", "", "88.6", "98.4", "", "", "", "", "96.5"]} +{"pcdb_id": 16367, "brand_name": "Glow-worm", "model_name": "Ultracom 2 35cxi", "model_qualifier": "", "winter_efficiency_pct": 89.7, "summer_efficiency_pct": 81.1, "comparative_hot_water_efficiency_pct": 57.1, "output_kw_max": 30.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016367", "000207", "0", "2013/Jan/30 14:47", "Vaillant Group UK", "Glow-worm", "Ultracom 2 35cxi", "", "G.C.No.47-019-12", "2010", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "30.0", "30.0", "", "", "89.7", "81.1", "", "57.1", "", "2", "1", "", "104", "1", "2", "151", "6", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.5", "100.6", "", "", "", "", "98.7"]} +{"pcdb_id": 16368, "brand_name": "Intergas", "model_name": "Compact HRE 30 OV", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 26.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016368", "000256", "0", "2012/Mar/27 10:12", "Intergas Heating Ltd", "Intergas", "Compact HRE 30 OV", "", "", "2009", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "26.6", "26.6", "", "", "88.5", "79.5", "", "58.0", "", "2", "", "", "102", "1", "2", "130", "1.9", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.9", "97.6", "", "", "", "", "95.9"]} +{"pcdb_id": 16369, "brand_name": "Intergas", "model_name": "Compact HRE 24 OV", "model_qualifier": "", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 23.1, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016369", "000256", "0", "2012/Mar/27 10:12", "Intergas Heating Ltd", "Intergas", "Compact HRE 24 OV", "", "", "2009", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "23.1", "23.1", "", "", "88.2", "79.2", "", "57.8", "", "2", "", "", "102", "1", "2", "130", "1.9", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "97.2", "", "", "", "", "95.5"]} +{"pcdb_id": 16371, "brand_name": "Intergas", "model_name": "Compact HRE 18 OV", "model_qualifier": "", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 18.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016371", "000256", "0", "2014/Nov/24 13:35", "Intergas Heating Ltd", "Intergas", "Compact HRE 18 OV", "", "", "2009", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18.2", "18.2", "", "", "88.2", "79.2", "", "57.9", "", "2", "", "", "102", "1", "2", "130", "1.9", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "97.4", "", "", "", "", "95.6"]} +{"pcdb_id": 16372, "brand_name": "Unical", "model_name": "Alkon 35 SC HE", "model_qualifier": "", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 55.7, "output_kw_max": 33.8, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016372", "000263", "0", "2010/May/27 11:08", "Unical", "Unical", "Alkon 35 SC HE", "", "", "2010", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "33.8", "33.8", "", "", "87.9", "79.3", "", "55.7", "", "2", "", "", "104", "1", "2", "130", "5", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.1", "96.4", "", "", "", "", "94.8"]} +{"pcdb_id": 16373, "brand_name": "Unical", "model_name": "Alkon 35 SR HE", "model_qualifier": "", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 78.9, "comparative_hot_water_efficiency_pct": 57.6, "output_kw_max": 33.8, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016373", "000263", "0", "2012/Mar/27 10:12", "Unical", "Unical", "Alkon 35 SR HE", "", "", "2010", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "33.8", "33.8", "", "", "87.9", "78.9", "", "57.6", "", "2", "", "", "102", "1", "2", "130", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.1", "96.4", "", "", "", "", "94.8"]} +{"pcdb_id": 16374, "brand_name": "Ideal", "model_name": "Independent", "model_qualifier": "C24", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 69.3, "output_kw_max": 24.2, "final_year_of_manufacture": 2016, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.008, "loss_factor_f1_kwh_per_day": 1.46665, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016374", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "Independent", "C24", "47-348-68", "2010", "2016", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "88.4", "87.3", "", "69.3", "", "2", "", "", "104", "1", "2", "146", "1", "0", "", "", "0", "0", "", "", "", "", "1", "7.5959", "0.1755", "0.008", "1.46665", "", "", "", "", "", "1", "1", "0", "0035", "", "", "", "", "", "", "", "", "89.8", "96.9", "", "", "", "", "95.6"]} +{"pcdb_id": 16375, "brand_name": "Ideal", "model_name": "Independent", "model_qualifier": "C30", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 69.8, "output_kw_max": 24.2, "final_year_of_manufacture": 2016, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0099, "loss_factor_f1_kwh_per_day": 1.41408, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016375", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "Independent", "C30", "47-348-69", "2010", "2016", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "88.4", "87.3", "", "69.8", "", "2", "", "", "104", "1", "2", "152", "1", "0", "", "", "0", "0", "", "", "", "", "1", "7.548", "0.1749", "0.0099", "1.41408", "", "", "", "", "", "1", "1", "0", "0035", "", "", "", "", "", "", "", "", "90.0", "96.9", "", "", "", "", "95.6"]} +{"pcdb_id": 16376, "brand_name": "Ideal", "model_name": "Independent", "model_qualifier": "C35", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 71.0, "output_kw_max": 24.2, "final_year_of_manufacture": 2016, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0087, "loss_factor_f1_kwh_per_day": 1.2937, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016376", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "Independent", "C35", "47-348-70", "2010", "2016", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "88.3", "87.3", "", "71.0", "", "2", "", "", "104", "1", "2", "177", "1", "0", "", "", "0", "0", "", "", "", "", "1", "7.4216", "0.171", "0.0087", "1.2937", "", "", "", "", "", "1", "1", "0", "0035", "", "", "", "", "", "", "", "", "89.8", "96.9", "", "", "", "", "95.5"]} +{"pcdb_id": 16378, "brand_name": "Sime", "model_name": "Format DGT HE", "model_qualifier": "20 System", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 19.5, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016378", "000213", "0", "2018/Feb/26 17:09", "Fonderie Sime S.p.A.", "Sime", "Format DGT HE", "20 System", "", "2009", "2018", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "19.5", "19.5", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "125", "8", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "96.9", "", "", "", "", "95.1"]} +{"pcdb_id": 16379, "brand_name": "Sime", "model_name": "Format DGT HE", "model_qualifier": "20 System", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 19.5, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016379", "000213", "0", "2018/Feb/28 16:49", "Fonderie Sime S.p.A.", "Sime", "Format DGT HE", "20 System", "", "2009", "2018", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "19.5", "19.5", "", "", "89.0", "80.0", "", "58.4", "", "2", "1", "", "102", "1", "2", "125", "8", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.8", "99.0", "", "", "", "", "97.3"]} +{"pcdb_id": 16380, "brand_name": "Navien", "model_name": "NCN-21K", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 56.4, "output_kw_max": 19.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016380", "000265", "0", "2011/May/27 12:32", "KD Navien", "Navien", "NCN-21K", "", "", "2010", "current", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "19.3", "19.3", "", "", "88.8", "80.2", "", "56.4", "", "2", "", "", "104", "1", "2", "130", "6.81", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.5", "98.6", "", "", "", "", "96.7"]} +{"pcdb_id": 16381, "brand_name": "Navien", "model_name": "NCN-21K", "model_qualifier": "", "winter_efficiency_pct": 89.8, "summer_efficiency_pct": 81.2, "comparative_hot_water_efficiency_pct": 57.1, "output_kw_max": 19.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016381", "000265", "0", "2011/May/27 12:32", "KD Navien", "Navien", "NCN-21K", "", "", "2010", "current", "2", "2", "1", "2", "0", "", "", "2", "3", "2", "19.3", "19.3", "", "", "89.8", "81.2", "", "57.1", "", "2", "1", "", "104", "1", "2", "130", "6.81", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.4", "100.8", "", "", "", "", "98.8"]} +{"pcdb_id": 16382, "brand_name": "Navien", "model_name": "NCN-25K", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 56.1, "output_kw_max": 23.1, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016382", "000265", "0", "2010/Jul/30 10:37", "KD Navien", "Navien", "NCN-25K", "", "", "2010", "current", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "23.1", "23.1", "", "", "88.4", "79.8", "", "56.1", "", "2", "", "", "104", "1", "2", "130", "6.81", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.4", "97.7", "", "", "", "", "95.9"]} +{"pcdb_id": 16383, "brand_name": "Navien", "model_name": "NCN-25K", "model_qualifier": "", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 56.8, "output_kw_max": 23.1, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016383", "000265", "0", "2010/Jul/30 10:37", "KD Navien", "Navien", "NCN-25K", "", "", "2010", "current", "2", "2", "1", "2", "0", "", "", "2", "3", "2", "23.1", "23.1", "", "", "89.4", "80.8", "", "56.8", "", "2", "1", "", "104", "1", "2", "130", "6.81", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.4", "99.8", "", "", "", "", "98.0"]} +{"pcdb_id": 16384, "brand_name": "Navien", "model_name": "NCN-32K", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 56.2, "output_kw_max": 29.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016384", "000265", "0", "2010/Jul/30 10:37", "KD Navien", "Navien", "NCN-32K", "", "", "2010", "current", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "29.5", "29.5", "", "", "88.5", "79.9", "", "56.2", "", "2", "", "", "104", "1", "2", "130", "6.81", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.7", "97.7", "", "", "", "", "96.0"]} +{"pcdb_id": 16385, "brand_name": "Navien", "model_name": "NCN-32K", "model_qualifier": "", "winter_efficiency_pct": 89.5, "summer_efficiency_pct": 80.9, "comparative_hot_water_efficiency_pct": 56.9, "output_kw_max": 29.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016385", "000265", "0", "2010/Aug/23 16:09", "KD Navien", "Navien", "NCN-32K", "", "", "2010", "current", "2", "2", "1", "2", "0", "", "", "2", "3", "2", "29.5", "29.5", "", "", "89.5", "80.9", "", "56.9", "", "2", "1", "", "104", "1", "2", "130", "6.81", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.6", "99.8", "", "", "", "", "98.1"]} +{"pcdb_id": 16386, "brand_name": "Navien", "model_name": "NCN-37K", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 56.1, "output_kw_max": 34.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016386", "000265", "0", "2010/Jul/30 10:38", "KD Navien", "Navien", "NCN-37K", "", "", "2010", "current", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "34.2", "34.2", "", "", "88.3", "79.7", "", "56.1", "", "2", "", "", "104", "1", "2", "130", "6.81", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "97.5", "", "", "", "", "95.7"]} +{"pcdb_id": 16387, "brand_name": "Navien", "model_name": "NCN-37K", "model_qualifier": "", "winter_efficiency_pct": 89.3, "summer_efficiency_pct": 80.7, "comparative_hot_water_efficiency_pct": 56.8, "output_kw_max": 34.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016387", "000265", "0", "2016/Jan/06 17:02", "KD Navien", "Navien", "NCN-37K", "", "", "2010", "current", "2", "2", "1", "2", "0", "", "", "2", "3", "2", "34.2", "34.2", "", "", "89.3", "80.7", "", "56.8", "", "2", "1", "", "104", "1", "2", "130", "6.81", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.3", "99.7", "", "", "", "", "97.9"]} +{"pcdb_id": 16388, "brand_name": "Ideal", "model_name": "Esprit 2", "model_qualifier": "24", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 62.1, "output_kw_max": 23.4, "final_year_of_manufacture": 2011, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016388", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "Esprit 2", "24", "47-348-71", "2010", "2011", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "23.4", "23.4", "", "", "88.1", "79.5", "", "62.1", "", "2", "", "", "104", "1", "2", "148", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "0", "0005", "", "", "", "", "", "", "", "", "87.9", "97.1", "", "", "", "", "95.4"]} +{"pcdb_id": 16389, "brand_name": "Ideal", "model_name": "Esprit 2", "model_qualifier": "30", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 62.1, "output_kw_max": 23.4, "final_year_of_manufacture": 2011, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016389", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "Esprit 2", "30", "47-348-72", "2010", "2011", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "23.4", "23.4", "", "", "88.1", "79.5", "", "62.1", "", "2", "", "", "104", "1", "2", "148", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "0", "0005", "", "", "", "", "", "", "", "", "87.9", "97.1", "", "", "", "", "95.4"]} +{"pcdb_id": 16390, "brand_name": "Ideal", "model_name": "Esprit 2", "model_qualifier": "35", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 62.1, "output_kw_max": 23.4, "final_year_of_manufacture": 2011, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016390", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "Esprit 2", "35", "47-348-73", "2010", "2011", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "23.4", "23.4", "", "", "88.1", "79.5", "", "62.1", "", "2", "", "", "104", "1", "2", "152", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "0", "0005", "", "", "", "", "", "", "", "", "87.9", "97.1", "", "", "", "", "95.4"]} +{"pcdb_id": 16393, "brand_name": "Ideal", "model_name": "Logic System", "model_qualifier": "30", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 30.3, "final_year_of_manufacture": 2016, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016393", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "Logic System", "30", "41-750-27", "2010", "2016", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "30.3", "30.3", "", "", "88.9", "79.9", "", "58.3", "", "2", "", "", "102", "1", "2", "152", "1", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "89.8", "98.2", "", "", "", "", "96.6"]} +{"pcdb_id": 16394, "brand_name": "Ideal", "model_name": "Logic System", "model_qualifier": "24", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 24.2, "final_year_of_manufacture": 2016, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016394", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "Logic System", "24", "41-750-26", "2010", "2016", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "88.8", "79.8", "", "58.3", "", "2", "", "", "102", "1", "2", "146", "1", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "89.6", "98.0", "", "", "", "", "96.4"]} +{"pcdb_id": 16395, "brand_name": "Ideal", "model_name": "Logic System", "model_qualifier": "18", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 18.0, "final_year_of_manufacture": 2016, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016395", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "Logic System", "18", "41-750-25", "2010", "2016", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18", "18", "", "", "88.5", "79.5", "", "58.1", "", "2", "", "", "102", "1", "2", "131", "1", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "89.6", "97.4", "", "", "", "", "95.9"]} +{"pcdb_id": 16396, "brand_name": "Ideal", "model_name": "Logic System", "model_qualifier": "15", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 15.0, "final_year_of_manufacture": 2016, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016396", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "Logic System", "15", "41-750-24", "2010", "2016", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "15", "15", "", "", "88.6", "79.6", "", "58.2", "", "2", "", "", "102", "1", "2", "126", "1", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "89.7", "97.7", "", "", "", "", "96.2"]} +{"pcdb_id": 16397, "brand_name": "Ideal", "model_name": "Logic Heat", "model_qualifier": "30", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 30.3, "final_year_of_manufacture": 2016, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016397", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "Logic Heat", "30", "41-409-96", "2010", "2016", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "30.3", "30.3", "", "", "88.9", "79.9", "", "58.3", "", "2", "", "", "102", "1", "2", "48", "1", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "89.8", "98.2", "", "", "", "", "96.6"]} +{"pcdb_id": 16398, "brand_name": "Ideal", "model_name": "Logic Heat", "model_qualifier": "24", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 24.2, "final_year_of_manufacture": 2016, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016398", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "Logic Heat", "24", "41-409-95", "2010", "2016", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "88.8", "79.8", "", "58.3", "", "2", "", "", "102", "1", "2", "46", "1", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "89.6", "98.0", "", "", "", "", "96.4"]} +{"pcdb_id": 16399, "brand_name": "Ideal", "model_name": "Logic Heat", "model_qualifier": "18", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 18.0, "final_year_of_manufacture": 2016, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016399", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "Logic Heat", "18", "41-409-94", "2010", "2016", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18", "18", "", "", "88.5", "79.5", "", "58.1", "", "2", "", "", "102", "1", "2", "31", "1", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "89.6", "97.4", "", "", "", "", "95.9"]} +{"pcdb_id": 16400, "brand_name": "Ideal", "model_name": "Logic Heat", "model_qualifier": "15", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 15.0, "final_year_of_manufacture": 2016, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016400", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "Logic Heat", "15", "41-409-93", "2010", "2016", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "15", "15", "", "", "88.6", "79.6", "", "58.2", "", "2", "", "", "102", "1", "2", "26", "1", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "89.7", "97.7", "", "", "", "", "96.2"]} +{"pcdb_id": 16401, "brand_name": "Ideal", "model_name": "Logic Heat", "model_qualifier": "12", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 12.0, "final_year_of_manufacture": 2016, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016401", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "Logic Heat", "12", "41-399-99", "2010", "2016", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "12", "12", "", "", "88.7", "79.7", "", "58.2", "", "2", "", "", "102", "1", "2", "23", "1", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "89.9", "97.7", "", "", "", "", "96.2"]} +{"pcdb_id": 16402, "brand_name": "Ideal", "model_name": "Logic + System", "model_qualifier": "15", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 15.0, "final_year_of_manufacture": 2016, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016402", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "Logic + System", "15", "41-750-29", "2010", "2016", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "15", "15", "", "", "88.6", "79.6", "", "58.2", "", "2", "", "", "102", "1", "2", "126", "1", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "89.7", "97.7", "", "", "", "", "96.2"]} +{"pcdb_id": 16403, "brand_name": "Ideal", "model_name": "Logic + System", "model_qualifier": "18", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 18.0, "final_year_of_manufacture": 2016, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016403", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "Logic + System", "18", "41-750-30", "2010", "2016", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18", "18", "", "", "88.5", "79.5", "", "58.1", "", "2", "", "", "102", "1", "2", "131", "1", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "89.6", "97.4", "", "", "", "", "95.9"]} +{"pcdb_id": 16404, "brand_name": "Ideal", "model_name": "Logic + System", "model_qualifier": "24", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 24.2, "final_year_of_manufacture": 2016, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016404", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "Logic + System", "24", "41-750-31", "2010", "2016", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "88.8", "79.8", "", "58.3", "", "2", "", "", "102", "1", "2", "146", "1", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "89.6", "98.0", "", "", "", "", "96.4"]} +{"pcdb_id": 16405, "brand_name": "Ideal", "model_name": "Logic + System", "model_qualifier": "30", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 30.3, "final_year_of_manufacture": 2016, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016405", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "Logic + System", "30", "41-750-32", "2010", "2016", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "30.3", "30.3", "", "", "88.9", "79.9", "", "58.3", "", "2", "", "", "102", "1", "2", "152", "1", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "89.8", "98.2", "", "", "", "", "96.6"]} +{"pcdb_id": 16406, "brand_name": "Ideal", "model_name": "Logic + Heat", "model_qualifier": "30", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 30.3, "final_year_of_manufacture": 2016, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016406", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "Logic + Heat", "30", "41-750-22", "2010", "2016", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "30.3", "30.3", "", "", "88.9", "79.9", "", "58.3", "", "2", "", "", "102", "1", "2", "48", "1", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "89.8", "98.2", "", "", "", "", "96.6"]} +{"pcdb_id": 16407, "brand_name": "Ideal", "model_name": "Logic + Heat", "model_qualifier": "24", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 24.2, "final_year_of_manufacture": 2016, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016407", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "Logic + Heat", "24", "41-750-21", "2010", "2016", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "88.8", "79.8", "", "58.3", "", "2", "", "", "102", "1", "2", "46", "1", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "89.6", "98.0", "", "", "", "", "96.4"]} +{"pcdb_id": 16408, "brand_name": "Ideal", "model_name": "Logic + Heat", "model_qualifier": "18", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 18.0, "final_year_of_manufacture": 2016, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016408", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "Logic + Heat", "18", "41-409-99", "2010", "2016", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18", "18", "", "", "88.5", "79.5", "", "58.1", "", "2", "", "", "102", "1", "2", "31", "1", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "89.6", "97.4", "", "", "", "", "95.9"]} +{"pcdb_id": 16409, "brand_name": "Ideal", "model_name": "Logic + Heat", "model_qualifier": "15", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 15.0, "final_year_of_manufacture": 2016, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016409", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "Logic + Heat", "15", "41-409-98", "2010", "2016", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "15", "15", "", "", "88.6", "79.6", "", "58.2", "", "2", "", "", "102", "1", "2", "26", "1", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "89.7", "97.7", "", "", "", "", "96.2"]} +{"pcdb_id": 16410, "brand_name": "Ideal", "model_name": "Logic + Heat", "model_qualifier": "12", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 12.0, "final_year_of_manufacture": 2016, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016410", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "Logic + Heat", "12", "41-409-97", "2010", "2016", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "12", "12", "", "", "88.7", "79.7", "", "58.2", "", "2", "", "", "102", "1", "2", "23", "1", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "89.9", "97.7", "", "", "", "", "96.2"]} +{"pcdb_id": 16411, "brand_name": "Keston", "model_name": "Keston", "model_qualifier": "30C", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 69.8, "output_kw_max": 24.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0099, "loss_factor_f1_kwh_per_day": 1.41408, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016411", "000022", "0", "2011/Oct/28 08:08", "Keston Boilers", "Keston", "Keston", "30C", "47-930-03", "2010", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "88.4", "87.3", "", "69.8", "", "2", "", "", "104", "1", "2", "152", "1", "0", "", "", "0", "0", "", "", "", "", "1", "7.548", "0.1749", "0.0099", "1.41408", "", "", "", "", "", "1", "1", "0", "0005", "", "", "", "", "", "", "", "", "90.0", "96.9", "", "", "", "", "95.6"]} +{"pcdb_id": 16412, "brand_name": "Viessmann", "model_name": "Vitodens 200W WB2C", "model_qualifier": "35kW System", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 32.2, "final_year_of_manufacture": 2013, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016412", "000033", "0", "2012/Mar/27 10:12", "Viessmann", "Viessmann", "Vitodens 200W WB2C", "35kW System", "41-819-17", "2009", "2013", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "32.2", "32.2", "", "", "88.5", "79.5", "", "58.1", "", "2", "", "", "102", "1", "2", "137", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.7", "97.8", "", "", "", "", "96.0"]} +{"pcdb_id": 16413, "brand_name": "Viessmann", "model_name": "Vitodens 200W WB2C", "model_qualifier": "35kW System", "winter_efficiency_pct": 89.5, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 58.8, "output_kw_max": 32.2, "final_year_of_manufacture": 2013, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016413", "000033", "0", "2012/Mar/27 10:12", "Viessmann", "Viessmann", "Vitodens 200W WB2C", "35kW System", "", "2009", "2013", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "32.2", "32.2", "", "", "89.5", "80.5", "", "58.8", "", "2", "1", "", "102", "1", "2", "137", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.6", "99.9", "", "", "", "", "98.2"]} +{"pcdb_id": 16414, "brand_name": "Viessmann", "model_name": "Vitodens 200W WB2C", "model_qualifier": "35kW Combi", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 56.2, "output_kw_max": 32.2, "final_year_of_manufacture": 2013, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016414", "000033", "0", "2012/Aug/28 09:59", "Viessmann", "Viessmann", "Vitodens 200W WB2C", "35kW Combi", "47-819-11", "2009", "2013", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "32.2", "32.2", "", "", "88.5", "79.9", "", "56.2", "", "2", "", "", "104", "1", "2", "137", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.7", "97.8", "", "", "", "", "96.0"]} +{"pcdb_id": 16415, "brand_name": "Viessmann", "model_name": "Vitodens 200W WB2C", "model_qualifier": "35kW Combi", "winter_efficiency_pct": 89.5, "summer_efficiency_pct": 80.9, "comparative_hot_water_efficiency_pct": 56.9, "output_kw_max": 32.2, "final_year_of_manufacture": 2013, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016415", "000033", "0", "2010/Aug/17 09:24", "Viessmann", "Viessmann", "Vitodens 200W WB2C", "35kW Combi", "", "2009", "2013", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "32.2", "32.2", "", "", "89.5", "80.9", "", "56.9", "", "2", "1", "", "104", "1", "2", "137", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.6", "99.9", "", "", "", "", "98.2"]} +{"pcdb_id": 16416, "brand_name": "Viessmann", "model_name": "Vitodens 200W WB2C", "model_qualifier": "30kW System", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 27.8, "final_year_of_manufacture": 2013, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016416", "000033", "0", "2012/Mar/27 10:12", "Viessmann", "Viessmann", "Vitodens 200W WB2C", "30kW System", "41-819-16", "2009", "2013", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "27.8", "27.8", "", "", "88.6", "79.6", "", "58.1", "", "2", "", "", "102", "1", "2", "100", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.2", "97.8", "", "", "", "", "96.1"]} +{"pcdb_id": 16417, "brand_name": "Viessmann", "model_name": "Vitodens 200W WB2C", "model_qualifier": "30kW System", "winter_efficiency_pct": 89.6, "summer_efficiency_pct": 80.6, "comparative_hot_water_efficiency_pct": 58.9, "output_kw_max": 27.8, "final_year_of_manufacture": 2013, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016417", "000033", "0", "2012/Mar/27 10:12", "Viessmann", "Viessmann", "Vitodens 200W WB2C", "30kW System", "", "2009", "2013", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "27.8", "27.8", "", "", "89.6", "80.6", "", "58.9", "", "2", "1", "", "102", "1", "2", "100", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "91.2", "99.9", "", "", "", "", "98.3"]} +{"pcdb_id": 16418, "brand_name": "Viessmann", "model_name": "Vitodens 200W WB2C", "model_qualifier": "30kW Combi", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 56.2, "output_kw_max": 27.8, "final_year_of_manufacture": 2013, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016418", "000033", "0", "2011/Jun/30 09:44", "Viessmann", "Viessmann", "Vitodens 200W WB2C", "30kW Combi", "47-819-10", "2009", "2013", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "27.8", "27.8", "", "", "88.6", "80.0", "", "56.2", "", "2", "", "", "104", "1", "2", "100", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.2", "97.8", "", "", "", "", "96.1"]} +{"pcdb_id": 16419, "brand_name": "Viessmann", "model_name": "Vitodens 200W WB2C", "model_qualifier": "30kW Combi", "winter_efficiency_pct": 89.6, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 57.0, "output_kw_max": 27.8, "final_year_of_manufacture": 2013, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016419", "000033", "0", "2010/Aug/17 09:33", "Viessmann", "Viessmann", "Vitodens 200W WB2C", "30kW Combi", "", "2009", "2013", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "27.8", "27.8", "", "", "89.6", "81.0", "", "57.0", "", "2", "1", "", "104", "1", "2", "100", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "91.2", "99.9", "", "", "", "", "98.3"]} +{"pcdb_id": 16420, "brand_name": "Viessmann", "model_name": "Vitodens 200W WB2C", "model_qualifier": "26kW System", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 24.1, "final_year_of_manufacture": 2013, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016420", "000033", "0", "2012/Mar/27 10:12", "Viessmann", "Viessmann", "Vitodens 200W WB2C", "26kW System", "41-819-15", "2009", "2013", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24.1", "24.1", "", "", "88.6", "79.6", "", "58.1", "", "2", "", "", "102", "1", "2", "95", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.9", "97.9", "", "", "", "", "96.2"]} +{"pcdb_id": 16421, "brand_name": "Viessmann", "model_name": "Vitodens 200W WB2C", "model_qualifier": "26kW System", "winter_efficiency_pct": 89.6, "summer_efficiency_pct": 80.6, "comparative_hot_water_efficiency_pct": 58.9, "output_kw_max": 24.1, "final_year_of_manufacture": 2013, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016421", "000033", "0", "2012/Mar/27 10:12", "Viessmann", "Viessmann", "Vitodens 200W WB2C", "26kW System", "", "2009", "2013", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "24.1", "24.1", "", "", "89.6", "80.6", "", "58.9", "", "2", "1", "", "102", "1", "2", "95", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.9", "100.1", "", "", "", "", "98.4"]} +{"pcdb_id": 16422, "brand_name": "Viessmann", "model_name": "Vitodens 200W WB2C", "model_qualifier": "26kW Combi", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 56.3, "output_kw_max": 24.1, "final_year_of_manufacture": 2013, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016422", "000033", "0", "2011/Jun/30 09:49", "Viessmann", "Viessmann", "Vitodens 200W WB2C", "26kW Combi", "47-819-09", "2009", "2013", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.1", "24.1", "", "", "88.6", "80.0", "", "56.3", "", "2", "", "", "104", "1", "2", "95", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.9", "97.9", "", "", "", "", "96.2"]} +{"pcdb_id": 16423, "brand_name": "Viessmann", "model_name": "Vitodens 200W WB2C", "model_qualifier": "26kW Combi", "winter_efficiency_pct": 89.6, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 57.0, "output_kw_max": 24.1, "final_year_of_manufacture": 2013, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016423", "000033", "0", "2010/Aug/16 08:12", "Viessmann", "Viessmann", "Vitodens 200W WB2C", "26kW Combi", "", "2009", "2013", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24.1", "24.1", "", "", "89.6", "81.0", "", "57.0", "", "2", "1", "", "104", "1", "2", "95", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.9", "100.1", "", "", "", "", "98.4"]} +{"pcdb_id": 16424, "brand_name": "Viessmann", "model_name": "Vitodens 200W WB2C", "model_qualifier": "19kW System", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 17.5, "final_year_of_manufacture": 2013, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016424", "000033", "0", "2012/Mar/27 10:12", "Viessmann", "Viessmann", "Vitodens 200W WB2C", "19kW System", "41-819-14", "2009", "2013", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "17.5", "17.5", "", "", "88.3", "79.3", "", "58.0", "", "2", "", "", "102", "1", "2", "85", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "97.7", "", "", "", "", "95.8"]} +{"pcdb_id": 16425, "brand_name": "Viessmann", "model_name": "Vitodens 200W WB2C", "model_qualifier": "19kW System", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 80.4, "comparative_hot_water_efficiency_pct": 58.7, "output_kw_max": 17.5, "final_year_of_manufacture": 2013, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016425", "000033", "0", "2012/Mar/27 10:12", "Viessmann", "Viessmann", "Vitodens 200W WB2C", "19kW System", "", "2009", "2013", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "17.5", "17.5", "", "", "89.4", "80.4", "", "58.7", "", "2", "1", "", "102", "1", "2", "85", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.0", "99.8", "", "", "", "", "98.0"]} +{"pcdb_id": 16426, "brand_name": "Viessmann", "model_name": "Vitodens 222F FS2B", "model_qualifier": "19kW Combi with Store", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 52.8, "output_kw_max": 17.5, "final_year_of_manufacture": 2012, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016426", "000033", "0", "2024/Jan/31 10:17", "Viessmann", "Viessmann", "Vitodens 222F FS2B", "19kW Combi with Store", "47-819-15", "2009", "2012", "1", "1", "1", "2", "0", "", "", "2", "2", "2", "17.5", "17.5", "", "", "88.3", "81.0", "", "52.8", "", "2", "", "", "106", "1", "2", "90", "", "2", "", "0", "100", "0", "50", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "97.7", "", "", "", "", "95.8"]} +{"pcdb_id": 16427, "brand_name": "Viessmann", "model_name": "Vitodens 222F FS2B", "model_qualifier": "19kW Combi with Store", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 82.1, "comparative_hot_water_efficiency_pct": 53.5, "output_kw_max": 17.5, "final_year_of_manufacture": 2012, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016427", "000033", "0", "2024/Jan/31 10:17", "Viessmann", "Viessmann", "Vitodens 222F FS2B", "19kW Combi with Store", "", "2009", "2012", "2", "1", "1", "2", "0", "", "", "2", "2", "2", "17.5", "17.5", "", "", "89.4", "82.1", "", "53.5", "", "2", "1", "", "106", "1", "2", "90", "", "2", "", "0", "100", "0", "50", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.0", "99.8", "", "", "", "", "98.0"]} +{"pcdb_id": 16428, "brand_name": "Viessmann", "model_name": "Vitodens 222F FS2B", "model_qualifier": "26kW Combi with Store", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 81.3, "comparative_hot_water_efficiency_pct": 53.0, "output_kw_max": 24.1, "final_year_of_manufacture": 2012, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016428", "000033", "0", "2024/Jan/31 10:17", "Viessmann", "Viessmann", "Vitodens 222F FS2B", "26kW Combi with Store", "47-819-16", "2009", "2012", "1", "1", "1", "2", "0", "", "", "2", "2", "2", "24.1", "24.1", "", "", "88.6", "81.3", "", "53.0", "", "2", "", "", "106", "1", "2", "105", "", "2", "", "0", "100", "0", "50", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.9", "97.9", "", "", "", "", "96.2"]} +{"pcdb_id": 16429, "brand_name": "Viessmann", "model_name": "Vitodens 222F FS2B", "model_qualifier": "26kW Combi with Store", "winter_efficiency_pct": 89.6, "summer_efficiency_pct": 82.3, "comparative_hot_water_efficiency_pct": 53.7, "output_kw_max": 24.1, "final_year_of_manufacture": 2012, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016429", "000033", "0", "2024/Jan/31 10:17", "Viessmann", "Viessmann", "Vitodens 222F FS2B", "26kW Combi with Store", "", "2009", "2012", "2", "1", "1", "2", "0", "", "", "2", "2", "2", "24.1", "24.1", "", "", "89.6", "82.3", "", "53.7", "", "2", "1", "", "106", "1", "2", "105", "", "2", "", "0", "100", "0", "50", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.9", "100.1", "", "", "", "", "98.4"]} +{"pcdb_id": 16430, "brand_name": "Viessmann", "model_name": "Vitodens 222F FS2B", "model_qualifier": "35kW Combi with Store", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 81.2, "comparative_hot_water_efficiency_pct": 50.4, "output_kw_max": 32.2, "final_year_of_manufacture": 2012, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016430", "000033", "0", "2024/Jan/31 10:17", "Viessmann", "Viessmann", "Vitodens 222F FS2B", "35kW Combi with Store", "47-819-17", "2009", "2012", "1", "1", "1", "2", "0", "", "", "2", "2", "2", "32.2", "32.2", "", "", "88.5", "81.2", "", "50.4", "", "2", "", "", "106", "1", "2", "138", "", "2", "", "0", "130", "0", "50", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.7", "97.8", "", "", "", "", "96.0"]} +{"pcdb_id": 16431, "brand_name": "Viessmann", "model_name": "Vitodens 222F FS2B", "model_qualifier": "35kW Combi with Store", "winter_efficiency_pct": 89.5, "summer_efficiency_pct": 82.2, "comparative_hot_water_efficiency_pct": 51.0, "output_kw_max": 32.2, "final_year_of_manufacture": 2012, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016431", "000033", "0", "2024/Jan/31 10:17", "Viessmann", "Viessmann", "Vitodens 222F FS2B", "35kW Combi with Store", "", "2009", "2012", "2", "1", "1", "2", "0", "", "", "2", "2", "2", "32.2", "32.2", "", "", "89.5", "82.2", "", "51.0", "", "2", "1", "", "106", "1", "2", "138", "", "2", "", "0", "130", "0", "50", "", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "0", "", "0005", "", "", "", "", "", "", "", "", "90.6", "99.9", "", "", "", "", "98.2"]} +{"pcdb_id": 16432, "brand_name": "Viessmann", "model_name": "Vitodens 242F FB2B", "model_qualifier": "19kW Combi with Store", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 46.8, "output_kw_max": 17.5, "final_year_of_manufacture": 2012, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016432", "000033", "0", "2024/Jan/31 10:17", "Viessmann", "Viessmann", "Vitodens 242F FB2B", "19kW Combi with Store", "47-819-18", "2009", "2012", "1", "1", "1", "2", "0", "", "", "2", "2", "2", "17.5", "17.5", "", "", "88.3", "81.0", "", "46.8", "", "2", "", "", "106", "1", "2", "90", "", "2", "", "0", "170", "0", "50", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "97.7", "", "", "", "", "95.8"]} +{"pcdb_id": 16433, "brand_name": "Viessmann", "model_name": "Vitodens 242F FB2B", "model_qualifier": "19kW Combi with Store", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 82.1, "comparative_hot_water_efficiency_pct": 47.4, "output_kw_max": 17.5, "final_year_of_manufacture": 2012, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016433", "000033", "0", "2024/Jan/31 10:17", "Viessmann", "Viessmann", "Vitodens 242F FB2B", "19kW Combi with Store", "", "2009", "2012", "2", "1", "1", "2", "0", "", "", "2", "2", "2", "17.5", "17.5", "", "", "89.4", "82.1", "", "47.4", "", "2", "1", "", "106", "1", "2", "90", "", "2", "", "0", "170", "0", "50", "", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "0", "", "0005", "", "", "", "", "", "", "", "", "90.0", "99.8", "", "", "", "", "98.0"]} +{"pcdb_id": 16434, "brand_name": "Viessmann", "model_name": "Vitodens 242F FB2B", "model_qualifier": "26kW Combi with Store", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 81.3, "comparative_hot_water_efficiency_pct": 47.0, "output_kw_max": 24.1, "final_year_of_manufacture": 2012, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016434", "000033", "0", "2024/Jan/31 10:17", "Viessmann", "Viessmann", "Vitodens 242F FB2B", "26kW Combi with Store", "47-819-19", "2009", "2012", "1", "1", "1", "2", "0", "", "", "2", "2", "2", "24.1", "24.1", "", "", "88.6", "81.3", "", "47.0", "", "2", "", "", "106", "1", "2", "105", "", "2", "", "0", "170", "0", "50", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.9", "97.9", "", "", "", "", "96.2"]} +{"pcdb_id": 16435, "brand_name": "Viessmann", "model_name": "Vitodens 242F FB2B", "model_qualifier": "26kW Combi with Store", "winter_efficiency_pct": 89.6, "summer_efficiency_pct": 82.3, "comparative_hot_water_efficiency_pct": 47.5, "output_kw_max": 24.1, "final_year_of_manufacture": 2012, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016435", "000033", "0", "2024/Jan/31 10:17", "Viessmann", "Viessmann", "Vitodens 242F FB2B", "26kW Combi with Store", "", "2009", "2012", "2", "1", "1", "2", "0", "", "", "2", "2", "2", "24.1", "24.1", "", "", "89.6", "82.3", "", "47.5", "", "2", "1", "", "106", "1", "2", "", "", "2", "", "0", "170", "0", "50", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.9", "100.1", "", "", "", "", "98.4"]} +{"pcdb_id": 16437, "brand_name": "EHC", "model_name": "Eco Save 32K", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 56.2, "output_kw_max": 29.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016437", "000266", "0", "2010/Jul/30 10:23", "KD Navien", "EHC", "Eco Save 32K", "", "", "2010", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "29.5", "29.5", "", "", "88.5", "79.9", "", "56.2", "", "2", "", "", "104", "1", "2", "135", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.7", "97.7", "", "", "", "", "96.0"]} +{"pcdb_id": 16438, "brand_name": "EHC", "model_name": "Eco Save 32k", "model_qualifier": "", "winter_efficiency_pct": 89.5, "summer_efficiency_pct": 80.9, "comparative_hot_water_efficiency_pct": 56.9, "output_kw_max": 29.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016438", "000266", "0", "2010/Aug/24 08:19", "KD Navien", "EHC", "Eco Save 32k", "", "", "2010", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "29.5", "29.5", "", "", "89.5", "80.9", "", "56.9", "", "2", "1", "", "104", "1", "2", "135", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.6", "99.8", "", "", "", "", "98.1"]} +{"pcdb_id": 16439, "brand_name": "EHC", "model_name": "Eco Save 25K", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 56.1, "output_kw_max": 23.1, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016439", "000266", "0", "2010/Jul/30 10:22", "KD Navien", "EHC", "Eco Save 25K", "", "", "2010", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "23.1", "23.1", "", "", "88.4", "79.8", "", "56.1", "", "2", "", "", "104", "1", "2", "130", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.4", "97.7", "", "", "", "", "95.9"]} +{"pcdb_id": 16440, "brand_name": "EHC", "model_name": "Eco Save 25K", "model_qualifier": "", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 56.8, "output_kw_max": 23.1, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016440", "000266", "0", "2010/Jul/30 10:23", "KD Navien", "EHC", "Eco Save 25K", "", "", "2010", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "23.1", "23.1", "", "", "89.4", "80.8", "", "56.8", "", "2", "1", "", "104", "1", "2", "130", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.4", "99.8", "", "", "", "", "98.0"]} +{"pcdb_id": 16441, "brand_name": "EHC", "model_name": "Eco Save 21K", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 56.4, "output_kw_max": 19.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016441", "000266", "0", "2011/May/25 09:28", "KD Navien", "EHC", "Eco Save 21K", "", "", "2010", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "19.3", "19.3", "", "", "88.8", "80.2", "", "56.4", "", "2", "", "", "104", "1", "2", "130", "6.81", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.5", "98.6", "", "", "", "", "96.7"]} +{"pcdb_id": 16442, "brand_name": "EHC", "model_name": "Eco Save 21K", "model_qualifier": "", "winter_efficiency_pct": 89.8, "summer_efficiency_pct": 81.2, "comparative_hot_water_efficiency_pct": 57.1, "output_kw_max": 19.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016442", "000266", "0", "2011/May/25 09:28", "KD Navien", "EHC", "Eco Save 21K", "", "", "2010", "current", "2", "2", "1", "2", "0", "", "", "2", "3", "2", "19.3", "19.3", "", "", "89.8", "81.2", "", "57.1", "", "2", "1", "", "104", "1", "2", "130", "6.81", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.4", "100.8", "", "", "", "", "98.8"]} +{"pcdb_id": 16443, "brand_name": "EHC", "model_name": "Eco Save 37k", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 56.1, "output_kw_max": 34.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016443", "000266", "0", "2010/Jul/30 10:24", "KD Navien", "EHC", "Eco Save 37k", "", "", "2010", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "34.2", "34.2", "", "", "88.3", "79.7", "", "56.1", "", "2", "", "", "104", "1", "2", "135", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "97.5", "", "", "", "", "95.7"]} +{"pcdb_id": 16444, "brand_name": "EHC", "model_name": "Eco Save 37k", "model_qualifier": "", "winter_efficiency_pct": 89.3, "summer_efficiency_pct": 80.7, "comparative_hot_water_efficiency_pct": 56.8, "output_kw_max": 34.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016444", "000266", "0", "2010/Jul/30 10:24", "KD Navien", "EHC", "Eco Save 37k", "", "", "2010", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "34.2", "34.2", "", "", "89.3", "80.7", "", "56.8", "", "2", "1", "", "104", "1", "2", "135", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.3", "99.7", "", "", "", "", "97.9"]} +{"pcdb_id": 16445, "brand_name": "ARCA", "model_name": "PIXELfast B 31 FC", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 81.5, "comparative_hot_water_efficiency_pct": 39.3, "output_kw_max": 30.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016445", "000261", "0", "2024/Jan/31 10:17", "ARCA", "ARCA", "PIXELfast B 31 FC", "", "", "2005", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "30.2", "30.2", "", "", "88.5", "81.5", "", "39.3", "", "2", "", "", "106", "1", "2", "150", "5", "2", "2", "0", "50", "0", "11", "2", "60", "62", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "97.9", "", "", "", "", "96.1"]} +{"pcdb_id": 16446, "brand_name": "ARCA", "model_name": "PIXELfast B 25 FC", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 81.5, "comparative_hot_water_efficiency_pct": 39.3, "output_kw_max": 24.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016446", "000261", "0", "2024/Jan/31 10:17", "ARCA", "ARCA", "PIXELfast B 25 FC", "", "", "2005", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.4", "24.4", "", "", "88.5", "81.5", "", "39.3", "", "2", "", "", "106", "1", "2", "150", "50", "2", "2", "0", "50", "0", "11", "2", "60", "62", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "97.9", "", "", "", "", "96.1"]} +{"pcdb_id": 16447, "brand_name": "Main", "model_name": "12 HE A", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 11.82, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016447", "000005", "0", "2015/Aug/06 13:11", "Baxi Heating UK", "Main", "12 HE A", "", "GC No. 41-467-16", "2010", "2015", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "11.82", "11.82", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "80", "1.07", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.6", "96.5", "", "", "", "", "95.0"]} +{"pcdb_id": 16448, "brand_name": "Main", "model_name": "15 HE A", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 15.24, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016448", "000005", "0", "2015/Aug/06 13:12", "Baxi Heating UK", "Main", "15 HE A", "", "GC No. 41-467-17", "2010", "2015", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "15.24", "15.24", "", "", "88.3", "79.3", "", "57.9", "", "2", "", "", "102", "1", "2", "80", "2.49", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.3", "96.5", "", "", "", "", "95.3"]} +{"pcdb_id": 16449, "brand_name": "Main", "model_name": "18 HE A", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 17.81, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016449", "000005", "0", "2015/Aug/06 13:12", "Baxi Heating UK", "Main", "18 HE A", "", "GC No. 41-467-18", "2010", "2015", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "17.81", "17.81", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "80", "2.49", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "96.8", "", "", "", "", "95.2"]} +{"pcdb_id": 16450, "brand_name": "Main", "model_name": "24 HE A", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 22.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016450", "000005", "0", "2015/Aug/06 13:13", "Baxi Heating UK", "Main", "24 HE A", "", "GC No. 41-467-19", "2010", "2015", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "22.00", "22.00", "", "", "88.1", "79.1", "", "57.8", "", "2", "", "", "102", "1", "2", "80", "2.49", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.5", "96.5", "", "", "", "", "95.2"]} +{"pcdb_id": 16451, "brand_name": "Main", "model_name": "30 HE A", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 30.18, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016451", "000005", "0", "2015/Aug/06 13:13", "Baxi Heating UK", "Main", "30 HE A", "", "GC No. 41-467-20", "2010", "2015", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "30.18", "30.18", "", "", "88.1", "79.1", "", "57.8", "", "2", "", "", "102", "1", "2", "80", "2.49", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.4", "96.4", "", "", "", "", "95.1"]} +{"pcdb_id": 16452, "brand_name": "Baxi", "model_name": "Solo", "model_qualifier": "12 HE A", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 11.82, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016452", "000005", "0", "2015/Aug/06 11:56", "Baxi Heating UK", "Baxi", "Solo", "12 HE A", "GC No. 41-075-65", "2010", "2015", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "11.82", "11.82", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "80", "1.07", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.6", "96.5", "", "", "", "", "95.0"]} +{"pcdb_id": 16453, "brand_name": "Baxi", "model_name": "Solo", "model_qualifier": "15 HE A", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 15.24, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016453", "000005", "0", "2015/Aug/06 11:56", "Baxi Heating UK", "Baxi", "Solo", "15 HE A", "GC No. 41-075-66", "2010", "2015", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "15.24", "15.24", "", "", "88.7", "79.7", "", "58.2", "", "2", "", "", "102", "1", "2", "80", "2.49", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.3", "97.7", "", "", "", "", "96.3"]} +{"pcdb_id": 16454, "brand_name": "Baxi", "model_name": "Solo", "model_qualifier": "18 HE A", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 17.81, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016454", "000005", "0", "2015/Aug/06 11:57", "Baxi Heating UK", "Baxi", "Solo", "18 HE A", "GC No. 41-075-67", "2010", "2015", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "17.81", "17.81", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "80", "2.49", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "96.8", "", "", "", "", "95.2"]} +{"pcdb_id": 16455, "brand_name": "Baxi", "model_name": "Solo", "model_qualifier": "24 HE A", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 22.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016455", "000005", "0", "2015/Aug/06 11:58", "Baxi Heating UK", "Baxi", "Solo", "24 HE A", "GC No. 41-075-68", "2010", "2015", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "22.0", "22.0", "", "", "88.1", "79.1", "", "57.8", "", "2", "", "", "102", "1", "2", "80", "2.49", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.5", "96.5", "", "", "", "", "95.2"]} +{"pcdb_id": 16456, "brand_name": "Baxi", "model_name": "Solo", "model_qualifier": "30 HE A", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 30.18, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016456", "000005", "0", "2015/Aug/06 11:59", "Baxi Heating UK", "Baxi", "Solo", "30 HE A", "GC No. 41-075-69", "2010", "2015", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "30.18", "30.18", "", "", "88.1", "79.1", "", "57.8", "", "2", "", "", "102", "1", "2", "80", "2.49", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.4", "96.4", "", "", "", "", "95.1"]} +{"pcdb_id": 16457, "brand_name": "Nova Florida", "model_name": "Pictor Condensing KC 24 Line Tech", "model_qualifier": "", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 55.7, "output_kw_max": 23.1, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016457", "000250", "0", "2010/Sep/14 11:43", "Fondital", "Nova Florida", "Pictor Condensing KC 24 Line Tech", "", "", "2006", "current", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "23.1", "23.1", "", "", "87.9", "79.3", "", "55.7", "", "2", "", "", "104", "1", "2", "155", "10", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "96.5", "", "", "", "", "94.9"]} +{"pcdb_id": 16458, "brand_name": "Nova Florida", "model_name": "Pictor Condensing KC 24 Line Tech", "model_qualifier": "", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 56.5, "output_kw_max": 23.1, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016458", "000250", "0", "2010/Sep/14 11:43", "Fondital", "Nova Florida", "Pictor Condensing KC 24 Line Tech", "", "", "2006", "current", "2", "2", "1", "2", "0", "", "", "2", "3", "2", "23.1", "23.1", "", "", "88.9", "80.3", "", "56.5", "", "2", "1", "", "104", "1", "2", "155", "10", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.8", "98.7", "", "", "", "", "97.0"]} +{"pcdb_id": 16459, "brand_name": "Nova Florida", "model_name": "Pictor Condensing KC 28 Line Tech", "model_qualifier": "", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 55.7, "output_kw_max": 25.55, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016459", "000250", "0", "2010/Sep/14 11:39", "Fondital", "Nova Florida", "Pictor Condensing KC 28 Line Tech", "", "", "2007", "current", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "25.55", "25.55", "", "", "87.9", "79.3", "", "55.7", "", "2", "", "", "104", "1", "2", "155", "10", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "96.5", "", "", "", "", "94.9"]} +{"pcdb_id": 16460, "brand_name": "Nova Florida", "model_name": "Pictor Condensing KC 28 Line Tech", "model_qualifier": "", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 56.4, "output_kw_max": 25.55, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016460", "000250", "0", "2010/Sep/14 11:39", "Fondital", "Nova Florida", "Pictor Condensing KC 28 Line Tech", "", "", "2007", "current", "2", "2", "1", "2", "0", "", "", "2", "3", "2", "25.55", "25.55", "", "", "88.9", "80.3", "", "56.4", "", "2", "1", "", "104", "1", "2", "155", "10", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.8", "98.6", "", "", "", "", "97.0"]} +{"pcdb_id": 16461, "brand_name": "Nova Florida", "model_name": "Pictor Condensing KC 32 Line Tech", "model_qualifier": "", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 55.8, "output_kw_max": 30.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016461", "000250", "0", "2010/Sep/14 11:40", "Fondital", "Nova Florida", "Pictor Condensing KC 32 Line Tech", "", "", "2006", "current", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "30.6", "30.6", "", "", "87.9", "79.3", "", "55.8", "", "2", "", "", "104", "1", "2", "155", "10", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "96.6", "", "", "", "", "94.9"]} +{"pcdb_id": 16462, "brand_name": "Nova Florida", "model_name": "Pictor Condensing KC 32 Line Tech", "model_qualifier": "", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 56.5, "output_kw_max": 30.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016462", "000250", "0", "2010/Sep/14 11:40", "Fondital", "Nova Florida", "Pictor Condensing KC 32 Line Tech", "", "", "2006", "current", "2", "2", "1", "2", "0", "", "", "2", "3", "1", "30.6", "30.6", "", "", "88.9", "80.3", "", "56.5", "", "2", "1", "", "104", "1", "2", "155", "10", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.9", "98.7", "", "", "", "", "97.1"]} +{"pcdb_id": 16463, "brand_name": "Nova Florida", "model_name": "Pictor Condensing KR 24 Line Tech", "model_qualifier": "", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 78.9, "comparative_hot_water_efficiency_pct": 57.6, "output_kw_max": 23.1, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016463", "000250", "0", "2012/Mar/27 10:12", "Fondital", "Nova Florida", "Pictor Condensing KR 24 Line Tech", "", "", "2006", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "23.1", "23.1", "", "", "87.9", "78.9", "", "57.6", "", "2", "", "", "102", "1", "2", "155", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "96.5", "", "", "", "", "94.9"]} +{"pcdb_id": 16464, "brand_name": "Nova Florida", "model_name": "Pictor Condensing KR 24 Line Tech", "model_qualifier": "", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 23.1, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016464", "000250", "0", "2012/Mar/27 10:12", "Fondital", "Nova Florida", "Pictor Condensing KR 24 Line Tech", "", "", "2006", "current", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "23.1", "23.1", "", "", "88.9", "79.9", "", "58.3", "", "2", "1", "", "102", "1", "2", "155", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.8", "98.6", "", "", "", "", "97.0"]} +{"pcdb_id": 16465, "brand_name": "Nova Florida", "model_name": "Pictor Condensing KR 28 Line Tech", "model_qualifier": "", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 78.9, "comparative_hot_water_efficiency_pct": 57.6, "output_kw_max": 25.55, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016465", "000250", "0", "2012/Mar/27 10:12", "Fondital", "Nova Florida", "Pictor Condensing KR 28 Line Tech", "", "", "2007", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "25.55", "25.55", "", "", "87.9", "78.9", "", "57.6", "", "2", "", "", "102", "1", "2", "155", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "96.5", "", "", "", "", "94.9"]} +{"pcdb_id": 16466, "brand_name": "Nova Florida", "model_name": "Pictor Condensing KR 28 Line Tech", "model_qualifier": "", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 25.55, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016466", "000250", "0", "2012/Mar/27 10:12", "Fondital", "Nova Florida", "Pictor Condensing KR 28 Line Tech", "", "", "2008", "current", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "25.55", "25.55", "", "", "88.9", "79.9", "", "58.3", "", "2", "1", "", "102", "1", "2", "155", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.8", "98.6", "", "", "", "", "97.0"]} +{"pcdb_id": 16467, "brand_name": "Nova Florida", "model_name": "Pictor Condensing KR 32 Line Tech", "model_qualifier": "", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 78.9, "comparative_hot_water_efficiency_pct": 57.6, "output_kw_max": 30.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016467", "000250", "0", "2012/Mar/27 10:12", "Fondital", "Nova Florida", "Pictor Condensing KR 32 Line Tech", "", "", "2006", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "30.6", "30.6", "", "", "87.9", "78.9", "", "57.6", "", "2", "", "", "102", "1", "2", "155", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "96.6", "", "", "", "", "94.9"]} +{"pcdb_id": 16468, "brand_name": "Nova Florida", "model_name": "Pictor Condensing KR 32 Line Tech", "model_qualifier": "", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 30.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016468", "000250", "0", "2012/Mar/27 10:12", "Fondital", "Nova Florida", "Pictor Condensing KR 32 Line Tech", "", "", "2006", "current", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "30.6", "30.6", "", "", "88.9", "79.9", "", "58.4", "", "2", "1", "", "102", "1", "2", "155", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.9", "98.7", "", "", "", "", "97.1"]} +{"pcdb_id": 16469, "brand_name": "Nova Florida", "model_name": "Pictor Condensing KRB 24 Line Tech", "model_qualifier": "", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 78.9, "comparative_hot_water_efficiency_pct": 57.6, "output_kw_max": 23.1, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016469", "000250", "0", "2012/Mar/27 10:12", "Fondital", "Nova Florida", "Pictor Condensing KRB 24 Line Tech", "", "", "2007", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "23.1", "23.1", "", "", "87.9", "78.9", "", "57.6", "", "2", "", "", "102", "1", "2", "155", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "96.5", "", "", "", "", "94.9"]} +{"pcdb_id": 16470, "brand_name": "Nova Florida", "model_name": "Pictor Condensing KRB 28 Line Tech", "model_qualifier": "", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 78.9, "comparative_hot_water_efficiency_pct": 57.6, "output_kw_max": 25.55, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016470", "000250", "0", "2012/Mar/27 10:12", "Fondital", "Nova Florida", "Pictor Condensing KRB 28 Line Tech", "", "", "2007", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "25.55", "25.55", "", "", "87.9", "78.9", "", "57.6", "", "2", "", "", "102", "1", "2", "155", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "96.5", "", "", "", "", "94.9"]} +{"pcdb_id": 16471, "brand_name": "Nova Florida", "model_name": "Pictor Condensing KRB 28 Line Tech", "model_qualifier": "", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 25.55, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016471", "000250", "0", "2012/Mar/27 10:12", "Fondital", "Nova Florida", "Pictor Condensing KRB 28 Line Tech", "", "", "2007", "current", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "25.55", "25.55", "", "", "88.9", "79.9", "", "58.3", "", "2", "1", "", "102", "1", "2", "155", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.8", "98.6", "", "", "", "", "97.0"]} +{"pcdb_id": 16472, "brand_name": "Nova Florida", "model_name": "Pictor Condensing KRB 32 Line Tech", "model_qualifier": "", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 78.9, "comparative_hot_water_efficiency_pct": 57.6, "output_kw_max": 30.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016472", "000250", "0", "2012/Mar/27 10:12", "Fondital", "Nova Florida", "Pictor Condensing KRB 32 Line Tech", "", "", "2007", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "30.6", "30.6", "", "", "87.9", "78.9", "", "57.6", "", "2", "", "", "102", "1", "2", "155", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "96.6", "", "", "", "", "94.9"]} +{"pcdb_id": 16473, "brand_name": "Nova Florida", "model_name": "Pictor Condensing KRB 32 Line Tech", "model_qualifier": "", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 30.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016473", "000250", "0", "2012/Mar/27 10:12", "Fondital", "Nova Florida", "Pictor Condensing KRB 32 Line Tech", "", "", "2007", "current", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "30.6", "30.6", "", "", "88.9", "79.9", "", "58.4", "", "2", "1", "", "102", "1", "2", "155", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.9", "98.7", "", "", "", "", "97.1"]} +{"pcdb_id": 16475, "brand_name": "Biasi", "model_name": "Activ A", "model_qualifier": "12OV", "winter_efficiency_pct": 87.7, "summer_efficiency_pct": 78.7, "comparative_hot_water_efficiency_pct": 57.5, "output_kw_max": 11.8, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016475", "000208", "0", "2012/Jun/28 11:09", "Biasi", "Biasi", "Activ A", "12OV", "41-583-14", "2010", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "11.8", "11.8", "", "", "87.7", "78.7", "", "57.5", "", "2", "", "", "102", "1", "2", "121", "5.4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "95.9", "", "", "", "", "94.4"]} +{"pcdb_id": 16477, "brand_name": "Biasi", "model_name": "Activ A", "model_qualifier": "12OV", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 11.8, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016477", "000208", "0", "2012/Mar/27 10:12", "Biasi", "Biasi", "Activ A", "12OV", "", "2010", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "11.8", "11.8", "", "", "88.7", "79.7", "", "58.2", "", "2", "1", "", "102", "1", "2", "121", "5.4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.3", "98.0", "", "", "", "", "96.5"]} +{"pcdb_id": 16478, "brand_name": "Biasi", "model_name": "Activ A", "model_qualifier": "15OV", "winter_efficiency_pct": 87.7, "summer_efficiency_pct": 78.7, "comparative_hot_water_efficiency_pct": 57.5, "output_kw_max": 14.7, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016478", "000208", "0", "2012/Jun/28 11:09", "Biasi", "Biasi", "Activ A", "15OV", "41-583-15", "2010", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "14.7", "14.7", "", "", "87.7", "78.7", "", "57.5", "", "2", "", "", "102", "1", "2", "125", "5.4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.1", "96.0", "", "", "", "", "94.5"]} +{"pcdb_id": 16480, "brand_name": "Biasi", "model_name": "Activ A", "model_qualifier": "15OV", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 14.7, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016480", "000208", "0", "2012/Mar/27 10:12", "Biasi", "Biasi", "Activ A", "15OV", "", "2010", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "14.7", "14.7", "", "", "88.7", "79.7", "", "58.2", "", "2", "1", "", "102", "1", "2", "125", "5.4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.1", "98.1", "", "", "", "", "96.6"]} +{"pcdb_id": 16481, "brand_name": "Biasi", "model_name": "Activ A", "model_qualifier": "20OV", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 19.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016481", "000208", "0", "2012/Jun/28 11:09", "Biasi", "Biasi", "Activ A", "20OV", "41-583-16", "2010", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "19.5", "19.5", "", "", "88.2", "79.2", "", "57.9", "", "2", "", "", "102", "1", "2", "139", "5.4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.1", "97.3", "", "", "", "", "95.6"]} +{"pcdb_id": 16482, "brand_name": "Biasi", "model_name": "Activ A", "model_qualifier": "20OV", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 19.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016482", "000208", "0", "2012/Mar/27 10:12", "Biasi", "Biasi", "Activ A", "20OV", "", "2010", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "19.5", "19.5", "", "", "89.2", "80.2", "", "58.6", "", "2", "1", "", "102", "1", "2", "139", "5.4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.1", "99.5", "", "", "", "", "97.7"]} +{"pcdb_id": 16483, "brand_name": "Biasi", "model_name": "Activ A", "model_qualifier": "25OV", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 24.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016483", "000208", "0", "2012/Jun/28 11:09", "Biasi", "Biasi", "Activ A", "25OV", "41-583-17", "2010", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24.5", "24.5", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "150", "5.4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.1", "96.9", "", "", "", "", "95.2"]} +{"pcdb_id": 16484, "brand_name": "Biasi", "model_name": "Activ A", "model_qualifier": "25OV", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 24.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016484", "000208", "0", "2012/Mar/27 10:12", "Biasi", "Biasi", "Activ A", "25OV", "", "2010", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "24.5", "24.5", "", "", "89.0", "80.0", "", "58.5", "", "2", "1", "", "102", "1", "2", "150", "5.4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.1", "99.0", "", "", "", "", "97.3"]} +{"pcdb_id": 16486, "brand_name": "Potterton", "model_name": "Gold", "model_qualifier": "H 24", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 22.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016486", "000005", "0", "2015/Aug/06 12:59", "Baxi Heating UK", "Potterton", "Gold", "H 24", "GC No 41-592-14", "2010", "2015", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "22.0", "22.0", "", "", "88.1", "79.1", "", "57.8", "", "2", "", "", "102", "1", "2", "80", "2.49", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.5", "96.5", "", "", "", "", "95.2"]} +{"pcdb_id": 16487, "brand_name": "Potterton", "model_name": "Gold", "model_qualifier": "H 18", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 17.81, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016487", "000005", "0", "2015/Aug/06 13:00", "Baxi Heating UK", "Potterton", "Gold", "H 18", "GC No 41-592-13", "2010", "2015", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "17.81", "17.81", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "80", "2.49", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "96.8", "", "", "", "", "95.2"]} +{"pcdb_id": 16488, "brand_name": "Potterton", "model_name": "Gold", "model_qualifier": "H 15", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 15.24, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016488", "000005", "0", "2015/Aug/06 13:00", "Baxi Heating UK", "Potterton", "Gold", "H 15", "GC No 41-592-12", "2010", "2015", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "15.24", "15.24", "", "", "88.3", "79.3", "", "57.9", "", "2", "", "", "102", "1", "2", "80", "2.49", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.3", "96.5", "", "", "", "", "95.3"]} +{"pcdb_id": 16489, "brand_name": "Nova Florida", "model_name": "Pictor Condensing KRB 24 Line Tech", "model_qualifier": "", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 23.1, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016489", "000250", "0", "2012/Mar/27 10:12", "Fondital", "Nova Florida", "Pictor Condensing KRB 24 Line Tech", "", "", "2001", "current", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "23.1", "23.1", "", "", "88.9", "79.9", "", "58.3", "", "2", "1", "", "102", "1", "2", "155", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.8", "98.6", "", "", "", "", "97.0"]} +{"pcdb_id": 16490, "brand_name": "Baxi Heating", "model_name": "Bermuda", "model_qualifier": "45/3M", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 13.19, "final_year_of_manufacture": 1997, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016490", "000005", "0", "2010/Sep/13 17:32", "Baxi Heating", "Baxi Heating", "Bermuda", "45/3M", "4407761", "1995", "1997", "1", "4", "1", "1", "0", "", "", "1", "1", "1", "10.26", "13.19", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "1", "", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 16491, "brand_name": "Baxi Heating", "model_name": "Bermuda", "model_qualifier": "57/3M", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 16.85, "final_year_of_manufacture": 1997, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016491", "000005", "0", "2010/Sep/13 17:32", "Baxi Heating", "Baxi Heating", "Bermuda", "57/3M", "4407763", "1995", "1997", "1", "4", "1", "1", "0", "", "", "1", "1", "1", "13.19", "16.85", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "1", "", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 16492, "brand_name": "Baxi Heating", "model_name": "Bermuda", "model_qualifier": "45/3E", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 13.19, "final_year_of_manufacture": 1997, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016492", "000005", "0", "2010/Sep/13 17:32", "Baxi Heating", "Baxi Heating", "Bermuda", "45/3E", "4407760", "1995", "1997", "1", "4", "1", "1", "0", "", "", "1", "1", "1", "10.26", "13.19", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "1", "1", "", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 16493, "brand_name": "Baxi Heating", "model_name": "Bermuda", "model_qualifier": "57/3E", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 16.85, "final_year_of_manufacture": 1997, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016493", "000005", "0", "2010/Sep/13 17:32", "Baxi Heating", "Baxi Heating", "Bermuda", "57/3E", "4407762", "1995", "1997", "1", "4", "1", "1", "0", "", "", "1", "1", "1", "13.19", "16.85", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "1", "1", "", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 16494, "brand_name": "Baxi Heating", "model_name": "Bermuda", "model_qualifier": "25/1", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 7.3, "final_year_of_manufacture": 1995, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016494", "000005", "0", "2010/Sep/13 17:32", "Baxi Heating", "Baxi Heating", "Bermuda", "25/1", "4407751", "1985", "1995", "1", "4", "1", "1", "0", "", "", "1", "1", "1", "4.40", "7.30", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "1", "1", "", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 16495, "brand_name": "Baxi Heating", "model_name": "Bermuda", "model_qualifier": "401", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 11.7, "final_year_of_manufacture": 1995, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016495", "000005", "0", "2010/Sep/13 17:32", "Baxi Heating", "Baxi Heating", "Bermuda", "401", "4407749", "1977", "1995", "1", "4", "1", "1", "0", "", "", "1", "1", "1", "4.40", "11.70", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "1", "1", "", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 16496, "brand_name": "Baxi Heating", "model_name": "Bermuda", "model_qualifier": "551", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 16.0, "final_year_of_manufacture": 1980, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016496", "000005", "0", "2010/Sep/13 17:32", "Baxi Heating", "Baxi Heating", "Bermuda", "551", "4407748", "1976", "1980", "1", "4", "1", "1", "0", "", "", "1", "1", "1", "10.00", "16.00", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "1", "1", "", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 16497, "brand_name": "Baxi Heating", "model_name": "Bermuda", "model_qualifier": "552", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 16.0, "final_year_of_manufacture": 1995, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016497", "000005", "0", "2010/Sep/13 17:32", "Baxi Heating", "Baxi Heating", "Bermuda", "552", "4407750", "1980", "1995", "1", "4", "1", "1", "0", "", "", "1", "1", "1", "10.00", "16.00", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "1", "1", "", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 16498, "brand_name": "Baxi Heating", "model_name": "Solo", "model_qualifier": "20/4 RS", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 5.86, "final_year_of_manufacture": 1993, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016498", "000005", "0", "2010/Sep/13 17:32", "Baxi Heating", "Baxi Heating", "Solo", "20/4 RS", "4107746", "1989", "1993", "1", "2", "1", "1", "0", "", "", "1", "2", "1", "3.22", "5.86", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "1", "", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 16499, "brand_name": "Baxi Heating", "model_name": "Solo", "model_qualifier": "30/4 RS", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 8.79, "final_year_of_manufacture": 1993, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016499", "000005", "0", "2010/Sep/13 17:32", "Baxi Heating", "Baxi Heating", "Solo", "30/4 RS", "4107747", "1989", "1993", "1", "2", "1", "1", "0", "", "", "1", "2", "1", "6.15", "8.79", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "1", "", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 16500, "brand_name": "Baxi Heating", "model_name": "Solo", "model_qualifier": "40/4 RS", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 11.72, "final_year_of_manufacture": 1993, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016500", "000005", "0", "2010/Sep/13 17:32", "Baxi Heating", "Baxi Heating", "Solo", "40/4 RS", "4107748", "1989", "1993", "1", "2", "1", "1", "0", "", "", "1", "2", "1", "9.09", "11.72", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "1", "", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 16501, "brand_name": "Baxi Heating", "model_name": "Solo", "model_qualifier": "50/4 RS", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 14.7, "final_year_of_manufacture": 1993, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016501", "000005", "0", "2010/Sep/13 17:32", "Baxi Heating", "Baxi Heating", "Solo", "50/4 RS", "4107749", "1989", "1993", "1", "2", "1", "1", "0", "", "", "1", "2", "1", "12", "14.7", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "1", "", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 16502, "brand_name": "Baxi Heating", "model_name": "Solo", "model_qualifier": "60/4 RS", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 17.58, "final_year_of_manufacture": 1993, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016502", "000005", "0", "2010/Sep/13 17:32", "Baxi Heating", "Baxi Heating", "Solo", "60/4 RS", "4107750", "1989", "1993", "1", "2", "1", "1", "0", "", "", "1", "2", "1", "14.95", "17.58", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "1", "", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 16503, "brand_name": "Baxi Heating", "model_name": "Solo", "model_qualifier": "20/4 RS SS", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 5.86, "final_year_of_manufacture": 1994, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016503", "000005", "0", "2010/Sep/13 17:32", "Baxi Heating", "Baxi Heating", "Solo", "20/4 RS SS", "4107756", "1991", "1994", "1", "2", "1", "1", "0", "", "", "1", "2", "1", "3.22", "5.86", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "1", "", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 16504, "brand_name": "Baxi Heating", "model_name": "Solo", "model_qualifier": "30/4 RS SS", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 8.79, "final_year_of_manufacture": 1994, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016504", "000005", "0", "2010/Sep/13 17:32", "Baxi Heating", "Baxi Heating", "Solo", "30/4 RS SS", "4107757", "1991", "1994", "1", "2", "1", "1", "0", "", "", "1", "2", "1", "6.15", "8.79", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "1", "", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 16505, "brand_name": "Baxi Heating", "model_name": "Solo", "model_qualifier": "40/4 RS SS", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 11.72, "final_year_of_manufacture": 1994, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016505", "000005", "0", "2010/Sep/13 17:32", "Baxi Heating", "Baxi Heating", "Solo", "40/4 RS SS", "4107758", "1991", "1994", "1", "2", "1", "1", "0", "", "", "1", "2", "1", "9.09", "11.72", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "1", "", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 16506, "brand_name": "Baxi Heating", "model_name": "Solo", "model_qualifier": "50/4 RS SS", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 14.7, "final_year_of_manufacture": 1994, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016506", "000005", "0", "2010/Sep/13 17:32", "Baxi Heating", "Baxi Heating", "Solo", "50/4 RS SS", "4107759", "1991", "1994", "1", "2", "1", "1", "0", "", "", "1", "2", "1", "12", "14.7", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "1", "", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 16507, "brand_name": "Baxi Heating", "model_name": "Solo", "model_qualifier": "60/4 RS SS", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 17.58, "final_year_of_manufacture": 1994, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016507", "000005", "0", "2010/Sep/13 17:32", "Baxi Heating", "Baxi Heating", "Solo", "60/4 RS SS", "4107760", "1991", "1994", "1", "2", "1", "1", "0", "", "", "1", "2", "1", "14.95", "17.58", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "1", "", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 16508, "brand_name": "Baxi Heating", "model_name": "Solo", "model_qualifier": "WM 30/4 PF", "winter_efficiency_pct": 69.0, "summer_efficiency_pct": 59.0, "comparative_hot_water_efficiency_pct": 43.0, "output_kw_max": 8.79, "final_year_of_manufacture": 1993, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016508", "000005", "0", "2010/Sep/13 17:32", "Baxi Heating", "Baxi Heating", "Solo", "WM 30/4 PF", "4107752", "1990", "1993", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "6.15", "8.79", "", "", "69.0", "59.0", "", "43.0", "", "3", "", "", "0", "1", "1", "", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 16509, "brand_name": "Baxi Heating", "model_name": "Solo", "model_qualifier": "WM 40/4 PF", "winter_efficiency_pct": 69.0, "summer_efficiency_pct": 59.0, "comparative_hot_water_efficiency_pct": 43.0, "output_kw_max": 11.72, "final_year_of_manufacture": 1993, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016509", "000005", "0", "2010/Sep/13 17:32", "Baxi Heating", "Baxi Heating", "Solo", "WM 40/4 PF", "4107753", "1990", "1993", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "9.08", "11.72", "", "", "69.0", "59.0", "", "43.0", "", "3", "", "", "0", "1", "1", "", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 16510, "brand_name": "Baxi Heating", "model_name": "Solo", "model_qualifier": "WM 50/4 PF", "winter_efficiency_pct": 69.0, "summer_efficiency_pct": 59.0, "comparative_hot_water_efficiency_pct": 43.0, "output_kw_max": 14.65, "final_year_of_manufacture": 1993, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016510", "000005", "0", "2010/Sep/13 17:32", "Baxi Heating", "Baxi Heating", "Solo", "WM 50/4 PF", "4107754", "1990", "1993", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "12.02", "14.65", "", "", "69.0", "59.0", "", "43.0", "", "3", "", "", "0", "1", "1", "", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 16511, "brand_name": "Baxi Heating", "model_name": "Solo", "model_qualifier": "WM 70/4 PF", "winter_efficiency_pct": 69.0, "summer_efficiency_pct": 59.0, "comparative_hot_water_efficiency_pct": 43.0, "output_kw_max": 20.5, "final_year_of_manufacture": 1993, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016511", "000005", "0", "2010/Sep/13 17:32", "Baxi Heating", "Baxi Heating", "Solo", "WM 70/4 PF", "4107755", "1990", "1993", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "15", "20.5", "", "", "69.0", "59.0", "", "43.0", "", "3", "", "", "0", "1", "1", "", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 16512, "brand_name": "Baxi Heating", "model_name": "Solo 2", "model_qualifier": "30 PF", "winter_efficiency_pct": 69.0, "summer_efficiency_pct": 59.0, "comparative_hot_water_efficiency_pct": 43.0, "output_kw_max": 8.79, "final_year_of_manufacture": 1999, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016512", "000005", "0", "2010/Sep/13 17:32", "Baxi Heating", "Baxi Heating", "Solo 2", "30 PF", "4107771", "1993", "1999", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "5.86", "8.79", "", "", "69.0", "59.0", "", "43.0", "", "3", "", "", "0", "1", "1", "", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 16513, "brand_name": "Baxi Heating", "model_name": "Solo 2", "model_qualifier": "40 PF", "winter_efficiency_pct": 69.0, "summer_efficiency_pct": 59.0, "comparative_hot_water_efficiency_pct": 43.0, "output_kw_max": 11.72, "final_year_of_manufacture": 1999, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016513", "000005", "0", "2010/Sep/13 17:32", "Baxi Heating", "Baxi Heating", "Solo 2", "40 PF", "4107772", "1993", "1999", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "9.09", "11.72", "", "", "69.0", "59.0", "", "43.0", "", "3", "", "", "0", "1", "1", "", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 16514, "brand_name": "Baxi Heating", "model_name": "Solo 2", "model_qualifier": "50 PF", "winter_efficiency_pct": 69.0, "summer_efficiency_pct": 59.0, "comparative_hot_water_efficiency_pct": 43.0, "output_kw_max": 14.65, "final_year_of_manufacture": 1999, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016514", "000005", "0", "2010/Sep/13 17:32", "Baxi Heating", "Baxi Heating", "Solo 2", "50 PF", "4107773", "1993", "1999", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "12.02", "14.65", "", "", "69.0", "59.0", "", "43.0", "", "3", "", "", "0", "1", "1", "", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 16515, "brand_name": "Baxi Heating", "model_name": "Solo 2", "model_qualifier": "60 PF", "winter_efficiency_pct": 69.0, "summer_efficiency_pct": 59.0, "comparative_hot_water_efficiency_pct": 43.0, "output_kw_max": 17.58, "final_year_of_manufacture": 1999, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016515", "000005", "0", "2010/Sep/13 17:32", "Baxi Heating", "Baxi Heating", "Solo 2", "60 PF", "4107774", "1993", "1999", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "14.95", "17.58", "", "", "69.0", "59.0", "", "43.0", "", "3", "", "", "0", "1", "1", "", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 16516, "brand_name": "Baxi Heating", "model_name": "Solo 2", "model_qualifier": "70 PF", "winter_efficiency_pct": 69.0, "summer_efficiency_pct": 59.0, "comparative_hot_water_efficiency_pct": 43.0, "output_kw_max": 20.5, "final_year_of_manufacture": 1999, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016516", "000005", "0", "2010/Sep/13 17:32", "Baxi Heating", "Baxi Heating", "Solo 2", "70 PF", "4107501", "1993", "1999", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "17.88", "20.5", "", "", "69.0", "59.0", "", "43.0", "", "3", "", "", "0", "1", "1", "", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 16517, "brand_name": "Baxi Heating", "model_name": "Solo 2", "model_qualifier": "80 PF", "winter_efficiency_pct": 69.0, "summer_efficiency_pct": 59.0, "comparative_hot_water_efficiency_pct": 43.0, "output_kw_max": 23.45, "final_year_of_manufacture": 1999, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016517", "000005", "0", "2010/Sep/13 17:32", "Baxi Heating", "Baxi Heating", "Solo 2", "80 PF", "4107775", "1993", "1999", "1", "2", "1", "1", "0", "", "", "1", "2", "2", "20.8", "23.45", "", "", "69.0", "59.0", "", "43.0", "", "3", "", "", "0", "1", "1", "", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 16518, "brand_name": "Baxi Heating", "model_name": "Solo 2", "model_qualifier": "30 RS", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 8.79, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016518", "000005", "0", "2010/Sep/13 17:32", "Baxi Heating", "Baxi Heating", "Solo 2", "30 RS", "4107776", "1994", "2001", "1", "2", "1", "1", "0", "", "", "1", "2", "1", "6.15", "8.79", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "1", "", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 16519, "brand_name": "Baxi Heating", "model_name": "Solo 2", "model_qualifier": "40 RS", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 11.72, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016519", "000005", "0", "2010/Sep/13 17:32", "Baxi Heating", "Baxi Heating", "Solo 2", "40 RS", "4107777", "1994", "2001", "1", "2", "1", "1", "0", "", "", "1", "2", "1", "9.09", "11.72", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "1", "", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 16520, "brand_name": "Baxi Heating", "model_name": "Solo 2", "model_qualifier": "50 RS", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 14.65, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016520", "000005", "0", "2010/Sep/13 17:32", "Baxi Heating", "Baxi Heating", "Solo 2", "50 RS", "4107778", "1994", "2001", "1", "2", "1", "1", "0", "", "", "1", "2", "1", "12.02", "14.65", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "1", "", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 16521, "brand_name": "Baxi Heating", "model_name": "Solo 2", "model_qualifier": "60 RS", "winter_efficiency_pct": 66.0, "summer_efficiency_pct": 56.0, "comparative_hot_water_efficiency_pct": 40.8, "output_kw_max": 17.58, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016521", "000005", "0", "2010/Sep/13 17:32", "Baxi Heating", "Baxi Heating", "Solo 2", "60 RS", "4107779", "1994", "2001", "1", "2", "1", "1", "0", "", "", "1", "2", "1", "14.95", "17.58", "", "", "66.0", "56.0", "", "40.8", "", "3", "", "", "0", "2", "1", "", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 16522, "brand_name": "Baxi Heating", "model_name": "Boston", "model_qualifier": "40 RS", "winter_efficiency_pct": 56.0, "summer_efficiency_pct": 46.0, "comparative_hot_water_efficiency_pct": 33.5, "output_kw_max": 11.7, "final_year_of_manufacture": 1995, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016522", "000005", "0", "2010/Sep/13 17:32", "Baxi Heating", "Baxi Heating", "Boston", "40 RS", "4107766", "1993", "1995", "1", "1", "1", "1", "0", "", "", "1", "2", "1", "9.1", "11.7", "", "", "56.0", "46.0", "", "33.5", "", "3", "", "", "0", "2", "1", "", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 16523, "brand_name": "Baxi Heating", "model_name": "Boston", "model_qualifier": "50 RS", "winter_efficiency_pct": 56.0, "summer_efficiency_pct": 46.0, "comparative_hot_water_efficiency_pct": 33.5, "output_kw_max": 14.65, "final_year_of_manufacture": 1995, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016523", "000005", "0", "2010/Sep/13 17:32", "Baxi Heating", "Baxi Heating", "Boston", "50 RS", "4107767", "1993", "1995", "1", "1", "1", "1", "0", "", "", "1", "2", "1", "12.02", "14.65", "", "", "56.0", "46.0", "", "33.5", "", "3", "", "", "0", "2", "1", "", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 16524, "brand_name": "Baxi Heating", "model_name": "Boston", "model_qualifier": "60 RS", "winter_efficiency_pct": 56.0, "summer_efficiency_pct": 46.0, "comparative_hot_water_efficiency_pct": 33.5, "output_kw_max": 17.6, "final_year_of_manufacture": 1995, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016524", "000005", "0", "2010/Sep/13 17:32", "Baxi Heating", "Baxi Heating", "Boston", "60 RS", "4107768", "1993", "1995", "1", "1", "1", "1", "0", "", "", "1", "2", "1", "14.95", "17.6", "", "", "56.0", "46.0", "", "33.5", "", "3", "", "", "0", "2", "1", "", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 16525, "brand_name": "Baxi Heating", "model_name": "Boston", "model_qualifier": "70 RS", "winter_efficiency_pct": 56.0, "summer_efficiency_pct": 46.0, "comparative_hot_water_efficiency_pct": 33.5, "output_kw_max": 20.5, "final_year_of_manufacture": 1995, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016525", "000005", "0", "2010/Sep/13 17:32", "Baxi Heating", "Baxi Heating", "Boston", "70 RS", "4107769", "1993", "1995", "1", "1", "1", "1", "0", "", "", "1", "2", "1", "17.8", "20.5", "", "", "56.0", "46.0", "", "33.5", "", "3", "", "", "0", "2", "1", "", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 16526, "brand_name": "Baxi Heating", "model_name": "Boston", "model_qualifier": "80 RS", "winter_efficiency_pct": 56.0, "summer_efficiency_pct": 46.0, "comparative_hot_water_efficiency_pct": 33.5, "output_kw_max": 23.4, "final_year_of_manufacture": 1995, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016526", "000005", "0", "2010/Sep/13 17:32", "Baxi Heating", "Baxi Heating", "Boston", "80 RS", "4107770", "1993", "1995", "1", "1", "1", "1", "0", "", "", "1", "2", "1", "20.8", "23.4", "", "", "56.0", "46.0", "", "33.5", "", "3", "", "", "0", "2", "1", "", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 16527, "brand_name": "Baxi Heating", "model_name": "Boston", "model_qualifier": "40 OF", "winter_efficiency_pct": 56.0, "summer_efficiency_pct": 46.0, "comparative_hot_water_efficiency_pct": 33.5, "output_kw_max": 11.7, "final_year_of_manufacture": 1995, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016527", "000005", "0", "2010/Sep/13 17:32", "Baxi Heating", "Baxi Heating", "Boston", "40 OF", "4107761", "1993", "1995", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "9.1", "11.7", "", "", "56.0", "46.0", "", "33.5", "", "3", "", "", "0", "2", "1", "", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 16528, "brand_name": "Baxi Heating", "model_name": "Boston", "model_qualifier": "50 OF", "winter_efficiency_pct": 56.0, "summer_efficiency_pct": 46.0, "comparative_hot_water_efficiency_pct": 33.5, "output_kw_max": 14.65, "final_year_of_manufacture": 1995, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016528", "000005", "0", "2010/Sep/13 17:32", "Baxi Heating", "Baxi Heating", "Boston", "50 OF", "4107762", "1993", "1995", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "12.02", "14.65", "", "", "56.0", "46.0", "", "33.5", "", "3", "", "", "0", "2", "1", "", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 16529, "brand_name": "Baxi Heating", "model_name": "Boston", "model_qualifier": "60 OF", "winter_efficiency_pct": 56.0, "summer_efficiency_pct": 46.0, "comparative_hot_water_efficiency_pct": 33.5, "output_kw_max": 17.6, "final_year_of_manufacture": 1995, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016529", "000005", "0", "2010/Sep/13 17:32", "Baxi Heating", "Baxi Heating", "Boston", "60 OF", "4107763", "1993", "1995", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "14.95", "17.6", "", "", "56.0", "46.0", "", "33.5", "", "3", "", "", "0", "2", "1", "", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 16530, "brand_name": "Baxi Heating", "model_name": "Boston", "model_qualifier": "70 OF", "winter_efficiency_pct": 56.0, "summer_efficiency_pct": 46.0, "comparative_hot_water_efficiency_pct": 33.5, "output_kw_max": 20.5, "final_year_of_manufacture": 1995, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016530", "000005", "0", "2010/Sep/13 17:32", "Baxi Heating", "Baxi Heating", "Boston", "70 OF", "4107764", "1993", "1995", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "17.8", "20.5", "", "", "56.0", "46.0", "", "33.5", "", "3", "", "", "0", "2", "1", "", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 16531, "brand_name": "Baxi Heating", "model_name": "Boston", "model_qualifier": "80 OF", "winter_efficiency_pct": 56.0, "summer_efficiency_pct": 46.0, "comparative_hot_water_efficiency_pct": 33.5, "output_kw_max": 23.4, "final_year_of_manufacture": 1995, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016531", "000005", "0", "2010/Sep/13 17:32", "Baxi Heating", "Baxi Heating", "Boston", "80 OF", "4107765", "1993", "1995", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "20.8", "23.4", "", "", "56.0", "46.0", "", "33.5", "", "3", "", "", "0", "2", "1", "", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 16532, "brand_name": "Baxi Heating", "model_name": "Boston 2", "model_qualifier": "40 RS", "winter_efficiency_pct": 56.0, "summer_efficiency_pct": 46.0, "comparative_hot_water_efficiency_pct": 33.5, "output_kw_max": 11.72, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016532", "000005", "0", "2010/Sep/13 17:32", "Baxi Heating", "Baxi Heating", "Boston 2", "40 RS", "4107785", "1995", "2001", "1", "1", "1", "1", "0", "", "", "1", "2", "1", "9.08", "11.72", "", "", "56.0", "46.0", "", "33.5", "", "3", "", "", "0", "2", "1", "", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 16533, "brand_name": "Baxi Heating", "model_name": "Boston 2", "model_qualifier": "50 RS", "winter_efficiency_pct": 56.0, "summer_efficiency_pct": 46.0, "comparative_hot_water_efficiency_pct": 33.5, "output_kw_max": 14.65, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016533", "000005", "0", "2010/Sep/13 17:32", "Baxi Heating", "Baxi Heating", "Boston 2", "50 RS", "4107786", "1995", "2001", "1", "1", "1", "1", "0", "", "", "1", "2", "1", "12.02", "14.65", "", "", "56.0", "46.0", "", "33.5", "", "3", "", "", "0", "2", "1", "", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 16534, "brand_name": "Baxi Heating", "model_name": "Boston 2", "model_qualifier": "60 RS", "winter_efficiency_pct": 56.0, "summer_efficiency_pct": 46.0, "comparative_hot_water_efficiency_pct": 33.5, "output_kw_max": 17.58, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016534", "000005", "0", "2010/Sep/13 17:32", "Baxi Heating", "Baxi Heating", "Boston 2", "60 RS", "4107787", "1995", "2001", "1", "1", "1", "1", "0", "", "", "1", "2", "1", "14.95", "17.58", "", "", "56.0", "46.0", "", "33.5", "", "3", "", "", "0", "2", "1", "", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 16535, "brand_name": "Baxi Heating", "model_name": "Boston 2", "model_qualifier": "70 RS", "winter_efficiency_pct": 56.0, "summer_efficiency_pct": 46.0, "comparative_hot_water_efficiency_pct": 33.5, "output_kw_max": 20.51, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016535", "000005", "0", "2010/Sep/13 17:32", "Baxi Heating", "Baxi Heating", "Boston 2", "70 RS", "4107788", "1995", "2001", "1", "1", "1", "1", "0", "", "", "1", "2", "1", "17.88", "20.51", "", "", "56.0", "46.0", "", "33.5", "", "3", "", "", "0", "2", "1", "", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 16536, "brand_name": "Baxi Heating", "model_name": "Boston 2", "model_qualifier": "80 RS", "winter_efficiency_pct": 56.0, "summer_efficiency_pct": 46.0, "comparative_hot_water_efficiency_pct": 33.5, "output_kw_max": 23.45, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016536", "000005", "0", "2010/Sep/13 17:32", "Baxi Heating", "Baxi Heating", "Boston 2", "80 RS", "4107789", "1995", "2001", "1", "1", "1", "1", "0", "", "", "1", "2", "1", "20.81", "23.45", "", "", "56.0", "46.0", "", "33.5", "", "3", "", "", "0", "2", "1", "", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 16537, "brand_name": "Baxi Heating", "model_name": "Boston 2", "model_qualifier": "40 OF", "winter_efficiency_pct": 56.0, "summer_efficiency_pct": 46.0, "comparative_hot_water_efficiency_pct": 33.5, "output_kw_max": 11.72, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016537", "000005", "0", "2010/Sep/13 17:32", "Baxi Heating", "Baxi Heating", "Boston 2", "40 OF", "4107780", "1995", "2001", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "9.08", "11.72", "", "", "56.0", "46.0", "", "33.5", "", "3", "", "", "0", "2", "1", "", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 16538, "brand_name": "Baxi Heating", "model_name": "Boston 2", "model_qualifier": "50 OF", "winter_efficiency_pct": 56.0, "summer_efficiency_pct": 46.0, "comparative_hot_water_efficiency_pct": 33.5, "output_kw_max": 14.65, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016538", "000005", "0", "2010/Sep/13 17:32", "Baxi Heating", "Baxi Heating", "Boston 2", "50 OF", "4107781", "1995", "2001", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "12.02", "14.65", "", "", "56.0", "46.0", "", "33.5", "", "3", "", "", "0", "2", "1", "", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 16539, "brand_name": "Baxi Heating", "model_name": "Boston 2", "model_qualifier": "60 OF", "winter_efficiency_pct": 56.0, "summer_efficiency_pct": 46.0, "comparative_hot_water_efficiency_pct": 33.5, "output_kw_max": 17.58, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016539", "000005", "0", "2010/Sep/13 17:32", "Baxi Heating", "Baxi Heating", "Boston 2", "60 OF", "4107782", "1995", "2001", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "14.95", "17.58", "", "", "56.0", "46.0", "", "33.5", "", "3", "", "", "0", "2", "1", "", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 16540, "brand_name": "Baxi Heating", "model_name": "Boston 2", "model_qualifier": "70 OF", "winter_efficiency_pct": 56.0, "summer_efficiency_pct": 46.0, "comparative_hot_water_efficiency_pct": 33.5, "output_kw_max": 20.51, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016540", "000005", "0", "2010/Sep/13 17:32", "Baxi Heating", "Baxi Heating", "Boston 2", "70 OF", "4107783", "1995", "2001", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "17.88", "20.51", "", "", "56.0", "46.0", "", "33.5", "", "3", "", "", "0", "2", "1", "", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 16541, "brand_name": "Baxi Heating", "model_name": "Boston 2", "model_qualifier": "80 OF", "winter_efficiency_pct": 56.0, "summer_efficiency_pct": 46.0, "comparative_hot_water_efficiency_pct": 33.5, "output_kw_max": 23.45, "final_year_of_manufacture": 2001, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016541", "000005", "0", "2010/Sep/13 17:32", "Baxi Heating", "Baxi Heating", "Boston 2", "80 OF", "4107784", "1995", "2001", "1", "1", "1", "1", "0", "", "", "1", "1", "1", "20.81", "23.45", "", "", "56.0", "46.0", "", "33.5", "", "3", "", "", "0", "2", "1", "", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 16542, "brand_name": "Baxi Heating", "model_name": "Genesis", "model_qualifier": "80", "winter_efficiency_pct": 71.0, "summer_efficiency_pct": 62.0, "comparative_hot_water_efficiency_pct": 43.2, "output_kw_max": 23.25, "final_year_of_manufacture": 2000, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016542", "000005", "0", "2010/Sep/13 17:32", "Baxi Heating", "Baxi Heating", "Genesis", "80", "4707701", "1995", "2000", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "23.25", "23.25", "", "", "71.0", "62.0", "", "43.2", "", "3", "", "", "0", "2", "1", "", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 16543, "brand_name": "Baxi Heating", "model_name": "Genesis", "model_qualifier": "96", "winter_efficiency_pct": 71.0, "summer_efficiency_pct": 62.0, "comparative_hot_water_efficiency_pct": 43.2, "output_kw_max": 28.0, "final_year_of_manufacture": 1998, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016543", "000005", "0", "2010/Sep/13 17:32", "Baxi Heating", "Baxi Heating", "Genesis", "96", "4707702", "1996", "1998", "1", "2", "1", "2", "0", "", "", "1", "2", "2", "28", "28", "", "", "71.0", "62.0", "", "43.2", "", "3", "", "", "0", "2", "1", "", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 16544, "brand_name": "Baxi", "model_name": "Combi", "model_qualifier": "105 HE A", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 55.9, "output_kw_max": 28.63, "final_year_of_manufacture": 2012, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016544", "000005", "0", "2013/May/07 10:37", "Baxi Heating UK", "Baxi", "Combi", "105 HE A", "GC No. 47-075-50", "2010", "2012", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28.63", "28.63", "", "", "88.1", "79.5", "", "55.9", "", "2", "", "", "104", "1", "2", "150", "4.09", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "97.0", "", "", "", "", "95.3"]} +{"pcdb_id": 16545, "brand_name": "Potterton", "model_name": "Gold Combi", "model_qualifier": "28 HE LPG", "winter_efficiency_pct": 90.4, "summer_efficiency_pct": 81.8, "comparative_hot_water_efficiency_pct": 57.5, "output_kw_max": 24.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016545", "000005", "0", "2010/Oct/27 07:56", "Baxi Heating UK", "Potterton", "Gold Combi", "28 HE LPG", "GC No. 47-393-30", "2010", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24.0", "24.0", "", "", "90.4", "81.8", "", "57.5", "", "2", "0", "", "104", "1", "2", "155", "4.75", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "92.0", "99.0", "", "", "", "", "97.7"]} +{"pcdb_id": 16546, "brand_name": "Potterton", "model_name": "Gold System", "model_qualifier": "28 HE A", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 28.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016546", "000005", "0", "2015/Aug/06 13:01", "Baxi Heating UK", "Potterton", "Gold System", "28 HE A", "GC No. 41-592-17", "2010", "2015", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "28.0", "28.0", "", "", "88.3", "79.3", "", "57.9", "", "2", "", "", "102", "1", "2", "160", "8.32", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.9", "96.7", "", "", "", "", "95.4"]} +{"pcdb_id": 16547, "brand_name": "Potterton", "model_name": "Gold System", "model_qualifier": "24 HE A", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 24.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016547", "000005", "0", "2015/Aug/06 13:02", "Baxi Heating UK", "Potterton", "Gold System", "24 HE A", "GC No. 41-592-16", "2010", "2015", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24.0", "24.0", "", "", "88.3", "79.3", "", "58.0", "", "2", "", "", "102", "1", "2", "150", "7.58", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.9", "96.9", "", "", "", "", "95.5"]} +{"pcdb_id": 16548, "brand_name": "Potterton", "model_name": "Gold System", "model_qualifier": "18 HE A", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 18.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016548", "000005", "0", "2015/Aug/06 13:03", "Baxi Heating UK", "Potterton", "Gold System", "18 HE A", "GC No. 41-592-15", "2010", "2015", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18.00", "18.00", "", "", "88.3", "79.3", "", "58.0", "", "2", "", "", "102", "1", "2", "140", "7.57", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.9", "96.9", "", "", "", "", "95.5"]} +{"pcdb_id": 16549, "brand_name": "Grant", "model_name": "Vortex 26-36 Boilerhouse", "model_qualifier": "", "winter_efficiency_pct": 90.5, "summer_efficiency_pct": 82.7, "comparative_hot_water_efficiency_pct": 60.4, "output_kw_max": 36.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016549", "000048", "0", "2012/Mar/27 10:12", "Grant Engineering UK Ltd", "Grant", "Vortex 26-36 Boilerhouse", "", "", "2010", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "26", "36", "", "", "90.5", "82.7", "", "60.4", "", "2", "", "", "201", "1", "1", "26", "36", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "95.1", "99.3", "", "", "", "", "98.5"]} +{"pcdb_id": 16550, "brand_name": "Grant", "model_name": "Vortex 26-36 Boilerhouse System", "model_qualifier": "", "winter_efficiency_pct": 90.5, "summer_efficiency_pct": 82.7, "comparative_hot_water_efficiency_pct": 60.4, "output_kw_max": 36.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016550", "000048", "0", "2012/Mar/27 10:12", "Grant Engineering UK Ltd", "Grant", "Vortex 26-36 Boilerhouse System", "", "", "2010", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "26", "36", "", "", "90.5", "82.7", "", "60.4", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "95.1", "99.8", "", "", "", "", "98.9"]} +{"pcdb_id": 16551, "brand_name": "Grant", "model_name": "Vortex 26-36 Outdoor Module System", "model_qualifier": "", "winter_efficiency_pct": 90.5, "summer_efficiency_pct": 82.7, "comparative_hot_water_efficiency_pct": 60.4, "output_kw_max": 36.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016551", "000048", "0", "2012/Mar/27 10:12", "Grant Engineering UK Ltd", "Grant", "Vortex 26-36 Outdoor Module System", "", "", "2010", "current", "4", "1", "2", "1", "0", "", "", "2", "3", "2", "26", "36", "", "", "90.5", "82.7", "", "60.4", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "95.1", "99.3", "", "", "", "", "98.5"]} +{"pcdb_id": 16552, "brand_name": "Grant", "model_name": "Vortex 20G Utility", "model_qualifier": "", "winter_efficiency_pct": 90.1, "summer_efficiency_pct": 82.3, "comparative_hot_water_efficiency_pct": 60.1, "output_kw_max": 20.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016552", "000048", "0", "2012/Mar/27 10:12", "Grant Engineering UK Ltd", "Grant", "Vortex 20G Utility", "", "", "2010", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "20", "20", "", "", "90.1", "82.3", "", "60.1", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "93.1", "99.0", "", "", "", "", "97.9"]} +{"pcdb_id": 16553, "brand_name": "Grant", "model_name": "Vortex 20G Utility System", "model_qualifier": "", "winter_efficiency_pct": 90.1, "summer_efficiency_pct": 82.3, "comparative_hot_water_efficiency_pct": 60.1, "output_kw_max": 20.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016553", "000048", "0", "2012/Mar/27 10:12", "Grant Engineering (UK)", "Grant", "Vortex 20G Utility System", "", "", "2010", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "20", "20", "", "", "90.1", "82.3", "", "60.1", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "93.1", "99.0", "", "", "", "", "97.9"]} +{"pcdb_id": 16554, "brand_name": "Grant", "model_name": "Vortex 20G Outdoor Module", "model_qualifier": "", "winter_efficiency_pct": 90.1, "summer_efficiency_pct": 82.3, "comparative_hot_water_efficiency_pct": 60.1, "output_kw_max": 20.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016554", "000048", "0", "2012/Mar/27 10:12", "Grant Engineering (UK)", "Grant", "Vortex 20G Outdoor Module", "", "", "2010", "current", "4", "1", "2", "1", "0", "", "", "2", "3", "2", "20", "20", "", "", "90.1", "82.3", "", "60.1", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "93.1", "99.0", "", "", "", "", "97.9"]} +{"pcdb_id": 16555, "brand_name": "Grant", "model_name": "Vortex 20G Outdoor Module System", "model_qualifier": "", "winter_efficiency_pct": 90.1, "summer_efficiency_pct": 82.3, "comparative_hot_water_efficiency_pct": 60.1, "output_kw_max": 20.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016555", "000048", "0", "2012/Mar/27 10:12", "Grant Engineering (UK)", "Grant", "Vortex 20G Outdoor Module System", "", "", "2010", "current", "4", "1", "2", "1", "0", "", "", "2", "3", "2", "20", "20", "", "", "90.1", "82.3", "", "60.1", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "93.1", "99.0", "", "", "", "", "97.9"]} +{"pcdb_id": 16556, "brand_name": "Grant", "model_name": "Vortex 20G Boilerhouse", "model_qualifier": "", "winter_efficiency_pct": 90.1, "summer_efficiency_pct": 82.3, "comparative_hot_water_efficiency_pct": 60.1, "output_kw_max": 20.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016556", "000048", "0", "2012/Mar/27 10:12", "Grant Engineering (UK)", "Grant", "Vortex 20G Boilerhouse", "", "", "2010", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "20", "20", "", "", "90.1", "82.3", "", "60.1", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "93.1", "99.0", "", "", "", "", "97.9"]} +{"pcdb_id": 16557, "brand_name": "Grant", "model_name": "Vortex 20G Boilerhouse System", "model_qualifier": "", "winter_efficiency_pct": 90.1, "summer_efficiency_pct": 82.3, "comparative_hot_water_efficiency_pct": 60.1, "output_kw_max": 20.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016557", "000048", "0", "2012/Mar/27 10:12", "Grant Engineering (UK)", "Grant", "Vortex 20G Boilerhouse System", "", "", "2010", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "20", "20", "", "", "90.1", "82.3", "", "60.1", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "93.1", "99.0", "", "", "", "", "97.9"]} +{"pcdb_id": 16558, "brand_name": "Grant", "model_name": "Vortex 30G Utility System", "model_qualifier": "", "winter_efficiency_pct": 89.7, "summer_efficiency_pct": 81.9, "comparative_hot_water_efficiency_pct": 59.8, "output_kw_max": 30.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016558", "000048", "0", "2012/Mar/27 10:12", "Grant Engineering (UK)", "Grant", "Vortex 30G Utility System", "", "", "2010", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "30", "30", "", "", "89.7", "81.9", "", "59.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "93.0", "98.3", "", "", "", "", "97.3"]} +{"pcdb_id": 16559, "brand_name": "Grant", "model_name": "Vortex 30G Outdoor Module", "model_qualifier": "", "winter_efficiency_pct": 89.7, "summer_efficiency_pct": 81.9, "comparative_hot_water_efficiency_pct": 59.8, "output_kw_max": 30.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016559", "000048", "0", "2012/Mar/27 10:12", "Grant Engineering (UK)", "Grant", "Vortex 30G Outdoor Module", "", "", "2010", "current", "4", "1", "2", "1", "0", "", "", "2", "3", "2", "30", "30", "", "", "89.7", "81.9", "", "59.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "93.0", "98.3", "", "", "", "", "97.3"]} +{"pcdb_id": 16560, "brand_name": "Grant", "model_name": "Vortex 30G Outdoor Module System", "model_qualifier": "", "winter_efficiency_pct": 89.7, "summer_efficiency_pct": 81.9, "comparative_hot_water_efficiency_pct": 59.8, "output_kw_max": 30.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016560", "000048", "0", "2012/Mar/27 10:12", "Grant Engineering (UK)", "Grant", "Vortex 30G Outdoor Module System", "", "", "2010", "current", "4", "1", "2", "1", "0", "", "", "2", "3", "2", "30", "30", "", "", "89.7", "81.9", "", "59.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "93.0", "98.3", "", "", "", "", "97.3"]} +{"pcdb_id": 16561, "brand_name": "Grant", "model_name": "Vortex 30G Boilerhouse", "model_qualifier": "", "winter_efficiency_pct": 89.7, "summer_efficiency_pct": 81.9, "comparative_hot_water_efficiency_pct": 59.8, "output_kw_max": 30.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016561", "000048", "0", "2012/Mar/27 10:12", "Grant Engineering (UK)", "Grant", "Vortex 30G Boilerhouse", "", "", "2010", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "30", "30", "", "", "89.7", "81.9", "", "59.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "93.0", "98.3", "", "", "", "", "97.3"]} +{"pcdb_id": 16562, "brand_name": "Grant", "model_name": "Vortex 30G Boilerhouse System", "model_qualifier": "", "winter_efficiency_pct": 89.7, "summer_efficiency_pct": 81.9, "comparative_hot_water_efficiency_pct": 59.8, "output_kw_max": 30.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016562", "000048", "0", "2012/Mar/27 10:12", "Grant Engineering (UK)", "Grant", "Vortex 30G Boilerhouse System", "", "", "2010", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "30", "30", "", "", "89.7", "81.9", "", "59.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "93.0", "98.3", "", "", "", "", "97.3"]} +{"pcdb_id": 16563, "brand_name": "Grant", "model_name": "Vortex 30G Utility", "model_qualifier": "", "winter_efficiency_pct": 89.7, "summer_efficiency_pct": 81.9, "comparative_hot_water_efficiency_pct": 59.8, "output_kw_max": 30.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016563", "000048", "0", "2012/Mar/27 10:12", "Grant Engineering (UK)", "Grant", "Vortex 30G Utility", "", "", "2010", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "30", "30", "", "", "89.7", "81.9", "", "59.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "93.0", "98.3", "", "", "", "", "97.3"]} +{"pcdb_id": 16564, "brand_name": "Sime", "model_name": "Format DGT HE", "model_qualifier": "12 System", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 11.3, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016564", "000213", "0", "2018/Feb/26 17:07", "Fonderie Sime S.p.A.", "Sime", "Format DGT HE", "12 System", "", "2009", "2018", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "11.3", "11.3", "", "", "88.5", "79.5", "", "58.0", "", "2", "", "", "102", "1", "2", "125", "8", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.5", "97.8", "", "", "", "", "96.0"]} +{"pcdb_id": 16565, "brand_name": "Sime", "model_name": "Format DGT HE", "model_qualifier": "12 System", "winter_efficiency_pct": 89.5, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 58.8, "output_kw_max": 11.3, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016565", "000213", "0", "2018/Feb/26 17:08", "Fonderie Sime S.p.A.", "Sime", "Format DGT HE", "12 System", "", "2009", "2018", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "11.3", "11.3", "", "", "89.5", "80.5", "", "58.8", "", "2", "1", "", "102", "1", "2", "125", "8", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.4", "99.9", "", "", "", "", "98.1"]} +{"pcdb_id": 16566, "brand_name": "Remeha", "model_name": "Quinta Pro 65", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 61.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016566", "000006", "0", "2012/Mar/27 10:12", "Broag Remeha", "Remeha", "Quinta Pro 65", "", "", "2010", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "61", "61", "", "", "88.6", "79.6", "", "58.2", "", "2", "", "", "102", "1", "2", "88", "6", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.6", "98.1", "", "", "", "", "96.3"]} +{"pcdb_id": 16567, "brand_name": "Remeha", "model_name": "Quinta Pro 45", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 40.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016567", "000006", "0", "2012/Mar/27 10:12", "Broag Remeha", "Remeha", "Quinta Pro 45", "", "", "2010", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "40", "40", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "68", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.6", "97.0", "", "", "", "", "95.2"]} +{"pcdb_id": 16570, "brand_name": "Glow-worm", "model_name": "Betacom 24a", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 56.1, "output_kw_max": 18.0, "final_year_of_manufacture": 2013, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016570", "000207", "0", "2013/Aug/23 09:29", "Glow-worm", "Glow-worm", "Betacom 24a", "", "GC No 47-019-13", "2010", "2013", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "18", "18", "", "", "88.4", "79.8", "", "56.1", "", "2", "", "", "104", "1", "2", "68", "6", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "97.8", "", "", "", "", "95.9"]} +{"pcdb_id": 16572, "brand_name": "Glow-worm", "model_name": "Betacom 24a", "model_qualifier": "", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 56.8, "output_kw_max": 18.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016572", "000207", "0", "2013/Jan/30 14:28", "Vaillant Industrial UK", "Glow-worm", "Betacom 24a", "", "", "2010", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "18", "18", "", "", "89.4", "80.8", "", "56.8", "", "2", "1", "", "104", "1", "2", "68", "6", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.8", "99.9", "", "", "", "", "98.0"]} +{"pcdb_id": 16573, "brand_name": "Glow-worm", "model_name": "Betacom 28a", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 56.2, "output_kw_max": 24.5, "final_year_of_manufacture": 2013, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016573", "000207", "0", "2013/Aug/23 09:29", "Vaillant", "Glow-worm", "Betacom 28a", "", "GC No 47-019-14", "2010", "2013", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.5", "24.5", "", "", "88.6", "80.0", "", "56.2", "", "2", "", "", "104", "1", "2", "68", "6", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "98.3", "", "", "", "", "96.3"]} +{"pcdb_id": 16574, "brand_name": "Glow-worm", "model_name": "Betacom 28a", "model_qualifier": "", "winter_efficiency_pct": 89.6, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 57.0, "output_kw_max": 24.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016574", "000207", "0", "2013/Jan/30 14:29", "Vaillant Industrial UK", "Glow-worm", "Betacom 28a", "", "", "2010", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24.5", "24.5", "", "", "89.6", "81.0", "", "57.0", "", "2", "1", "", "104", "1", "2", "68", "6", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.9", "100.5", "", "", "", "", "98.5"]} +{"pcdb_id": 16575, "brand_name": "Mistral", "model_name": "Lo-Nox BF CKUT 1 15/20", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 59.2, "output_kw_max": 20.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016575", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "Lo-Nox BF CKUT 1 15/20", "", "", "2010", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "15", "20", "", "", "88.8", "81.0", "", "59.2", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.9", "96.3", "", "", "", "", "95.5"]} +{"pcdb_id": 16576, "brand_name": "Mistral", "model_name": "Lo-Nox BF CKUT 2 20/27", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 59.2, "output_kw_max": 27.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016576", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "Lo-Nox BF CKUT 2 20/27", "", "", "2010", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "20", "27", "", "", "88.8", "81.0", "", "59.2", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.9", "96.3", "", "", "", "", "95.5"]} +{"pcdb_id": 16577, "brand_name": "Mistral", "model_name": "Lo-Nox BF CKUT 3 27/35", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 59.2, "output_kw_max": 35.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016577", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "Lo-Nox BF CKUT 3 27/35", "", "", "2010", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "27", "35", "", "", "88.8", "81.0", "", "59.2", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.9", "96.3", "", "", "", "", "95.5"]} +{"pcdb_id": 16578, "brand_name": "Mistral", "model_name": "Lo-Nox BF CKUT 4 35/42", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 59.2, "output_kw_max": 42.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016578", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "Lo-Nox BF CKUT 4 35/42", "", "", "2010", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "35", "42", "", "", "88.8", "81.0", "", "59.2", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.9", "96.3", "", "", "", "", "95.5"]} +{"pcdb_id": 16579, "brand_name": "Mistral", "model_name": "Lo-Nox BF CS1 15/20", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 59.2, "output_kw_max": 20.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016579", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "Lo-Nox BF CS1 15/20", "", "", "2010", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "15", "20", "", "", "88.8", "81.0", "", "59.2", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.9", "96.3", "", "", "", "", "95.5"]} +{"pcdb_id": 16580, "brand_name": "Mistral", "model_name": "Lo-Nox BF CS2 20/27", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 59.2, "output_kw_max": 27.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016580", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "Lo-Nox BF CS2 20/27", "", "", "2010", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "20", "27", "", "", "88.8", "81.0", "", "59.2", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.9", "96.3", "", "", "", "", "95.5"]} +{"pcdb_id": 16581, "brand_name": "Mistral", "model_name": "Lo-Nox BF CS3 27/35", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 59.2, "output_kw_max": 35.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016581", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "Lo-Nox BF CS3 27/35", "", "", "2010", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "27", "35", "", "", "88.8", "81.0", "", "59.2", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.9", "96.3", "", "", "", "", "95.5"]} +{"pcdb_id": 16582, "brand_name": "Mistral", "model_name": "Lo-Nox BF CS4 35/42", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 59.2, "output_kw_max": 42.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016582", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "Lo-Nox BF CS4 35/42", "", "", "2010", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "35", "42", "", "", "88.8", "81.0", "", "59.2", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.9", "96.3", "", "", "", "", "95.5"]} +{"pcdb_id": 16584, "brand_name": "Mistral", "model_name": "Lo-Nox BF CBH 1 15/20", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 59.2, "output_kw_max": 20.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016584", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "Lo-Nox BF CBH 1 15/20", "", "", "2010", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "15", "20", "", "", "88.8", "81.0", "", "59.2", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.9", "96.3", "", "", "", "", "95.5"]} +{"pcdb_id": 16585, "brand_name": "Mistral", "model_name": "Lo-Nox BF CBH 2 20/27", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 59.2, "output_kw_max": 27.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016585", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "Lo-Nox BF CBH 2 20/27", "", "", "2010", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "20", "27", "", "", "88.8", "81.0", "", "59.2", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.9", "96.3", "", "", "", "", "95.5"]} +{"pcdb_id": 16586, "brand_name": "Mistral", "model_name": "Lo-Nox BF CBH 3 27/35", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 59.2, "output_kw_max": 35.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016586", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "Lo-Nox BF CBH 3 27/35", "", "", "2010", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "27", "35", "", "", "88.8", "81.0", "", "59.2", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.9", "96.3", "", "", "", "", "95.5"]} +{"pcdb_id": 16587, "brand_name": "Mistral", "model_name": "Lo-Nox BF CBH 4 35/42", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 59.2, "output_kw_max": 42.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016587", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "Lo-Nox BF CBH 4 35/42", "", "", "2010", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "35", "42", "", "", "88.8", "81.0", "", "59.2", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.9", "96.3", "", "", "", "", "95.5"]} +{"pcdb_id": 16588, "brand_name": "Mistral", "model_name": "Lo-Nox BF CC1 15/20", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 81.4, "comparative_hot_water_efficiency_pct": 57.2, "output_kw_max": 20.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016588", "000056", "0", "2010/Nov/30 10:26", "Mistral Boilers", "Mistral", "Lo-Nox BF CC1 15/20", "", "", "2010", "current", "4", "1", "1", "2", "0", "", "", "2", "3", "1", "15", "20", "", "", "88.8", "81.4", "", "57.2", "", "2", "", "", "202", "1", "1", "", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.9", "96.3", "", "", "", "", "95.5"]} +{"pcdb_id": 16589, "brand_name": "Mistral", "model_name": "Lo-Nox BF CC2 20/27", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 81.4, "comparative_hot_water_efficiency_pct": 57.2, "output_kw_max": 27.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016589", "000056", "0", "2010/Nov/30 10:26", "Mistral Boilers", "Mistral", "Lo-Nox BF CC2 20/27", "", "", "2010", "current", "4", "1", "1", "2", "0", "", "", "2", "3", "1", "20", "27", "", "", "88.8", "81.4", "", "57.2", "", "2", "", "", "202", "1", "1", "", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.9", "96.3", "", "", "", "", "95.5"]} +{"pcdb_id": 16590, "brand_name": "Mistral", "model_name": "Lo-Nox BF CC3 27/35", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 81.4, "comparative_hot_water_efficiency_pct": 57.2, "output_kw_max": 35.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016590", "000056", "0", "2010/Nov/30 10:26", "Mistral Boilers", "Mistral", "Lo-Nox BF CC3 27/35", "", "", "2010", "current", "4", "1", "1", "2", "0", "", "", "2", "3", "1", "27", "35", "", "", "88.8", "81.4", "", "57.2", "", "2", "", "", "202", "1", "1", "", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.9", "96.3", "", "", "", "", "95.5"]} +{"pcdb_id": 16591, "brand_name": "Mistral", "model_name": "Lo-Nox BF CC4 35/42", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 81.4, "comparative_hot_water_efficiency_pct": 57.2, "output_kw_max": 42.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016591", "000056", "0", "2010/Nov/30 10:26", "Mistral Boilers", "Mistral", "Lo-Nox BF CC4 35/42", "", "", "2010", "current", "4", "1", "1", "2", "0", "", "", "2", "3", "1", "35", "42", "", "", "88.8", "81.4", "", "57.2", "", "2", "", "", "202", "1", "1", "", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.9", "96.3", "", "", "", "", "95.5"]} +{"pcdb_id": 16592, "brand_name": "Mistral", "model_name": "Lo-Nox BF CC1 Plus 15/20", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 81.4, "comparative_hot_water_efficiency_pct": 57.2, "output_kw_max": 20.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016592", "000056", "0", "2010/Nov/30 10:26", "Mistral Boilers", "Mistral", "Lo-Nox BF CC1 Plus 15/20", "", "", "2010", "current", "4", "1", "1", "2", "0", "", "", "2", "3", "1", "15", "20", "", "", "88.8", "81.4", "", "57.2", "", "2", "", "", "202", "1", "1", "", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.9", "96.3", "", "", "", "", "95.5"]} +{"pcdb_id": 16593, "brand_name": "Mistral", "model_name": "Lo-Nox BF CC2 Plus 20/27", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 81.4, "comparative_hot_water_efficiency_pct": 57.2, "output_kw_max": 27.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016593", "000056", "0", "2010/Nov/30 10:26", "Mistral Boilers", "Mistral", "Lo-Nox BF CC2 Plus 20/27", "", "", "2010", "current", "4", "1", "1", "2", "0", "", "", "2", "3", "1", "20", "27", "", "", "88.8", "81.4", "", "57.2", "", "2", "", "", "202", "1", "1", "", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.9", "96.3", "", "", "", "", "95.5"]} +{"pcdb_id": 16594, "brand_name": "Mistral", "model_name": "Lo-Nox BF CC3 Plus 27/35", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 81.4, "comparative_hot_water_efficiency_pct": 57.2, "output_kw_max": 35.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016594", "000056", "0", "2010/Nov/30 10:26", "Mistral Boilers", "Mistral", "Lo-Nox BF CC3 Plus 27/35", "", "", "2010", "current", "4", "1", "1", "2", "0", "", "", "2", "3", "1", "27", "35", "", "", "88.8", "81.4", "", "57.2", "", "2", "", "", "202", "1", "1", "", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.9", "96.3", "", "", "", "", "95.5"]} +{"pcdb_id": 16595, "brand_name": "Mistral", "model_name": "Lo-Nox BF CC4 Plus 35/42", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 81.4, "comparative_hot_water_efficiency_pct": 57.2, "output_kw_max": 42.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016595", "000056", "0", "2010/Nov/30 10:26", "Mistral Boilers", "Mistral", "Lo-Nox BF CC4 Plus 35/42", "", "", "2010", "current", "4", "1", "1", "2", "0", "", "", "2", "3", "1", "35", "42", "", "", "88.8", "81.4", "", "57.2", "", "2", "", "", "202", "1", "1", "", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.9", "96.3", "", "", "", "", "95.5"]} +{"pcdb_id": 16596, "brand_name": "Mistral", "model_name": "Lo-Nox BF COD1 15/20", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 59.2, "output_kw_max": 20.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016596", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "Lo-Nox BF COD1 15/20", "", "", "2010", "current", "4", "1", "2", "1", "0", "", "", "2", "3", "1", "15", "20", "", "", "88.8", "81.0", "", "59.2", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.9", "96.3", "", "", "", "", "95.5"]} +{"pcdb_id": 16597, "brand_name": "Mistral", "model_name": "Lo-Nox BF COD2 20/27", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 59.2, "output_kw_max": 27.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016597", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "Lo-Nox BF COD2 20/27", "", "", "2010", "current", "4", "1", "2", "1", "0", "", "", "2", "3", "1", "20", "27", "", "", "88.8", "81.0", "", "59.2", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.9", "96.3", "", "", "", "", "95.5"]} +{"pcdb_id": 16598, "brand_name": "Mistral", "model_name": "Lo-Nox BF COD3 27/35", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 59.2, "output_kw_max": 35.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016598", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "Lo-Nox BF COD3 27/35", "", "", "2010", "current", "4", "1", "2", "1", "0", "", "", "2", "3", "1", "27", "35", "", "", "88.8", "81.0", "", "59.2", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.9", "96.3", "", "", "", "", "95.5"]} +{"pcdb_id": 16599, "brand_name": "Mistral", "model_name": "Lo-Nox BF COD4 35/42", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 59.2, "output_kw_max": 42.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016599", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "Lo-Nox BF COD4 35/42", "", "", "2010", "current", "4", "1", "2", "1", "0", "", "", "2", "3", "1", "35", "42", "", "", "88.8", "81.0", "", "59.2", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.9", "96.3", "", "", "", "", "95.5"]} +{"pcdb_id": 16600, "brand_name": "Mistral", "model_name": "Lo-Nox BF CODSS1 15/20", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 59.2, "output_kw_max": 20.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016600", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "Lo-Nox BF CODSS1 15/20", "", "", "2010", "current", "4", "1", "2", "1", "0", "", "", "2", "3", "1", "15", "20", "", "", "88.8", "81.0", "", "59.2", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.9", "96.3", "", "", "", "", "95.5"]} +{"pcdb_id": 16601, "brand_name": "Mistral", "model_name": "Lo-Nox BF CODSS2 20/27", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 59.2, "output_kw_max": 27.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016601", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "Lo-Nox BF CODSS2 20/27", "", "", "2010", "current", "4", "1", "2", "1", "0", "", "", "2", "3", "1", "20", "27", "", "", "88.8", "81.0", "", "59.2", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.9", "96.3", "", "", "", "", "95.5"]} +{"pcdb_id": 16602, "brand_name": "Mistral", "model_name": "Lo-Nox BF CODSS3 27/35", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 59.2, "output_kw_max": 35.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016602", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "Lo-Nox BF CODSS3 27/35", "", "", "2010", "current", "4", "1", "2", "1", "0", "", "", "2", "3", "1", "27", "35", "", "", "88.8", "81.0", "", "59.2", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.9", "96.3", "", "", "", "", "95.5"]} +{"pcdb_id": 16603, "brand_name": "Mistral", "model_name": "Lo-Nox BF CODSS4 35/42", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 59.2, "output_kw_max": 42.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016603", "000056", "0", "2012/Mar/27 10:12", "Mistral Boilers", "Mistral", "Lo-Nox BF CODSS4 35/42", "", "", "2010", "current", "4", "1", "2", "1", "0", "", "", "2", "3", "1", "35", "42", "", "", "88.8", "81.0", "", "59.2", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.9", "96.3", "", "", "", "", "95.5"]} +{"pcdb_id": 16604, "brand_name": "Mistral", "model_name": "Lo-Nox BF CODC1 15/20", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 81.4, "comparative_hot_water_efficiency_pct": 57.2, "output_kw_max": 20.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016604", "000056", "0", "2010/Nov/30 10:27", "Mistral Boilers", "Mistral", "Lo-Nox BF CODC1 15/20", "", "", "2010", "current", "4", "1", "2", "2", "0", "", "", "2", "3", "1", "15", "20", "", "", "88.8", "81.4", "", "57.2", "", "2", "", "", "202", "1", "1", "", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.9", "96.3", "", "", "", "", "95.5"]} +{"pcdb_id": 16605, "brand_name": "Mistral", "model_name": "Lo-Nox BF CODC2 20/27", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 81.4, "comparative_hot_water_efficiency_pct": 57.2, "output_kw_max": 27.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016605", "000056", "0", "2010/Nov/30 10:27", "Mistral Boilers", "Mistral", "Lo-Nox BF CODC2 20/27", "", "", "2010", "current", "4", "1", "2", "2", "0", "", "", "2", "3", "1", "20", "27", "", "", "88.8", "81.4", "", "57.2", "", "2", "", "", "202", "1", "1", "", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.9", "96.3", "", "", "", "", "95.5"]} +{"pcdb_id": 16606, "brand_name": "Mistral", "model_name": "Lo-Nox BF CODC3 Plus 27/35", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 81.4, "comparative_hot_water_efficiency_pct": 57.2, "output_kw_max": 35.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016606", "000056", "0", "2010/Nov/30 10:27", "Mistral Boilers", "Mistral", "Lo-Nox BF CODC3 Plus 27/35", "", "", "2010", "current", "4", "1", "2", "2", "0", "", "", "2", "3", "1", "27", "35", "", "", "88.8", "81.4", "", "57.2", "", "2", "", "", "202", "1", "1", "", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.9", "96.3", "", "", "", "", "95.5"]} +{"pcdb_id": 16607, "brand_name": "Mistral", "model_name": "Lo-Nox BF CODC4 35/42", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 81.4, "comparative_hot_water_efficiency_pct": 57.2, "output_kw_max": 42.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016607", "000056", "0", "2010/Nov/30 10:27", "Mistral Boilers", "Mistral", "Lo-Nox BF CODC4 35/42", "", "", "2010", "current", "4", "1", "2", "2", "0", "", "", "2", "3", "1", "35", "42", "", "", "88.8", "81.4", "", "57.2", "", "2", "", "", "202", "1", "1", "", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.9", "96.3", "", "", "", "", "95.5"]} +{"pcdb_id": 16608, "brand_name": "Mistral", "model_name": "Lo-Nox BF CODC1 Plus 15/20", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 81.4, "comparative_hot_water_efficiency_pct": 57.2, "output_kw_max": 20.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016608", "000056", "0", "2010/Nov/30 10:27", "Mistral Boilers", "Mistral", "Lo-Nox BF CODC1 Plus 15/20", "", "", "2010", "current", "4", "1", "2", "2", "0", "", "", "2", "3", "1", "15", "20", "", "", "88.8", "81.4", "", "57.2", "", "2", "", "", "202", "1", "1", "", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.9", "96.3", "", "", "", "", "95.5"]} +{"pcdb_id": 16609, "brand_name": "Mistral", "model_name": "Lo-Nox BF CODC2 Plus 20/27", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 81.4, "comparative_hot_water_efficiency_pct": 57.2, "output_kw_max": 27.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016609", "000056", "0", "2010/Nov/30 10:27", "Mistral Boilers", "Mistral", "Lo-Nox BF CODC2 Plus 20/27", "", "", "2010", "current", "4", "1", "2", "2", "0", "", "", "2", "3", "1", "20", "27", "", "", "88.8", "81.4", "", "57.2", "", "2", "", "", "202", "1", "1", "", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.9", "96.3", "", "", "", "", "95.5"]} +{"pcdb_id": 16610, "brand_name": "Mistral", "model_name": "Lo-Nox BF CODC3 27/35", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 81.4, "comparative_hot_water_efficiency_pct": 57.2, "output_kw_max": 35.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016610", "000056", "0", "2010/Nov/30 10:27", "Mistral Boilers", "Mistral", "Lo-Nox BF CODC3 27/35", "", "", "2010", "current", "4", "1", "2", "2", "0", "", "", "2", "3", "1", "27", "35", "", "", "88.8", "81.4", "", "57.2", "", "2", "", "", "202", "1", "1", "", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.9", "96.3", "", "", "", "", "95.5"]} +{"pcdb_id": 16611, "brand_name": "Mistral", "model_name": "Lo-Nox BF CODC4 Plus 35/42", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 81.4, "comparative_hot_water_efficiency_pct": 57.2, "output_kw_max": 42.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016611", "000056", "0", "2010/Nov/30 10:27", "Mistral Boilers", "Mistral", "Lo-Nox BF CODC4 Plus 35/42", "", "", "2010", "current", "4", "1", "2", "2", "0", "", "", "2", "3", "1", "35", "42", "", "", "88.8", "81.4", "", "57.2", "", "2", "", "", "202", "1", "1", "", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.9", "96.3", "", "", "", "", "95.5"]} +{"pcdb_id": 16612, "brand_name": "Ravenheat", "model_name": "Combiplus 32", "model_qualifier": "Natural Gas", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 87.1, "comparative_hot_water_efficiency_pct": 81.2, "output_kw_max": 25.74, "final_year_of_manufacture": null, "subsidiary_type": 1, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0057, "loss_factor_f1_kwh_per_day": 0.39333, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016612", "000026", "0", "2011/Mar/25 16:31", "Ravenheat", "Ravenheat", "Combiplus 32", "Natural Gas", "", "2009", "current", "1", "2", "1", "2", "1", "", "", "2", "2", "2", "25.74", "25.74", "", "", "88.8", "87.1", "", "81.2", "", "2", "", "", "104", "1", "2", "160", "0", "0", "", "", "", "0", "", "", "", "", "1", "6.4894", "0.2674", "0.0057", "0.39333", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.2", "98.4", "", "", "", "", "96.6"]} +{"pcdb_id": 16613, "brand_name": "Ravenheat", "model_name": "Combiplus 32", "model_qualifier": "LPG", "winter_efficiency_pct": 89.8, "summer_efficiency_pct": 81.2, "comparative_hot_water_efficiency_pct": 57.1, "output_kw_max": 25.74, "final_year_of_manufacture": null, "subsidiary_type": 1, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016613", "000026", "0", "2013/Apr/08 09:36", "Ravenheat", "Ravenheat", "Combiplus 32", "LPG", "", "2009", "current", "2", "2", "1", "2", "1", "", "", "2", "2", "2", "25.74", "25.74", "", "", "89.8", "81.2", "", "57.1", "", "2", "1", "", "104", "1", "2", "160", "0", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "91.2", "100.6", "", "", "", "", "98.8"]} +{"pcdb_id": 16614, "brand_name": "Ravenheat", "model_name": "Combiplus 32 (T)", "model_qualifier": "Natural Gas", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 87.1, "comparative_hot_water_efficiency_pct": 81.2, "output_kw_max": 25.74, "final_year_of_manufacture": null, "subsidiary_type": 1, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0057, "loss_factor_f1_kwh_per_day": 0.39333, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016614", "000026", "0", "2011/Mar/25 16:32", "Ravenheat", "Ravenheat", "Combiplus 32 (T)", "Natural Gas", "", "2009", "current", "1", "2", "1", "2", "1", "", "", "2", "2", "2", "25.74", "25.74", "", "", "88.8", "87.1", "", "81.2", "", "2", "", "", "104", "1", "2", "160", "0", "0", "", "", "", "0", "", "", "", "", "1", "6.4894", "0.2674", "0.0057", "0.39333", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.2", "98.4", "", "", "", "", "96.6"]} +{"pcdb_id": 16615, "brand_name": "Ravenheat", "model_name": "Combiplus 32 (T)", "model_qualifier": "LPG", "winter_efficiency_pct": 89.8, "summer_efficiency_pct": 81.2, "comparative_hot_water_efficiency_pct": 57.1, "output_kw_max": 25.74, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016615", "000026", "0", "2013/Apr/08 09:39", "Ravenheat", "Ravenheat", "Combiplus 32 (T)", "LPG", "", "2009", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "25.74", "25.74", "", "", "89.8", "81.2", "", "57.1", "", "2", "1", "", "104", "1", "2", "160", "0", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "91.2", "100.6", "", "", "", "", "98.8"]} +{"pcdb_id": 16616, "brand_name": "Ravenheat", "model_name": "Combistore 32", "model_qualifier": "Natural Gas", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 87.1, "comparative_hot_water_efficiency_pct": 82.5, "output_kw_max": 25.74, "final_year_of_manufacture": null, "subsidiary_type": 1, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0064, "loss_factor_f1_kwh_per_day": 0.28564, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016616", "000026", "0", "2011/Mar/25 16:32", "Ravenheat", "Ravenheat", "Combistore 32", "Natural Gas", "", "2009", "current", "1", "2", "1", "2", "1", "", "", "2", "2", "2", "25.74", "25.74", "", "", "88.8", "87.1", "", "82.5", "", "2", "", "", "104", "1", "2", "160", "0", "0", "", "", "", "0", "", "", "", "", "1", "6.3819", "0.2665", "0.0064", "0.28564", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.2", "98.4", "", "", "", "", "96.6"]} +{"pcdb_id": 16617, "brand_name": "Ravenheat", "model_name": "Combistore 32", "model_qualifier": "LPG", "winter_efficiency_pct": 89.8, "summer_efficiency_pct": 81.2, "comparative_hot_water_efficiency_pct": 57.1, "output_kw_max": 25.74, "final_year_of_manufacture": null, "subsidiary_type": 1, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016617", "000026", "0", "2013/Apr/08 09:39", "Ravenheat", "Ravenheat", "Combistore 32", "LPG", "", "2009", "current", "2", "2", "1", "2", "1", "", "", "2", "2", "2", "25.74", "25.74", "", "", "89.8", "81.2", "", "57.1", "", "2", "1", "", "104", "1", "2", "160", "0", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "91.2", "100.6", "", "", "", "", "98.8"]} +{"pcdb_id": 16618, "brand_name": "Ravenheat", "model_name": "Combistore 32 (T)", "model_qualifier": "Natural Gas", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 87.1, "comparative_hot_water_efficiency_pct": 82.5, "output_kw_max": 25.74, "final_year_of_manufacture": null, "subsidiary_type": 1, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0064, "loss_factor_f1_kwh_per_day": 0.28564, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016618", "000026", "0", "2011/Mar/25 16:33", "Ravenheat", "Ravenheat", "Combistore 32 (T)", "Natural Gas", "", "2009", "current", "1", "2", "1", "2", "1", "", "", "2", "2", "2", "25.74", "25.74", "", "", "88.8", "87.1", "", "82.5", "", "2", "", "", "104", "1", "2", "160", "0", "0", "", "", "", "0", "", "", "", "", "1", "6.3819", "0.2665", "0.0064", "0.28564", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.2", "98.4", "", "", "", "", "96.6"]} +{"pcdb_id": 16619, "brand_name": "Ravenheat", "model_name": "Combistore 32 (T)", "model_qualifier": "LPG", "winter_efficiency_pct": 89.8, "summer_efficiency_pct": 81.2, "comparative_hot_water_efficiency_pct": 57.1, "output_kw_max": 25.74, "final_year_of_manufacture": null, "subsidiary_type": 1, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016619", "000026", "0", "2013/Apr/08 09:42", "Ravenheat", "Ravenheat", "Combistore 32 (T)", "LPG", "", "2009", "current", "2", "2", "1", "2", "1", "", "", "2", "2", "2", "25.74", "25.74", "", "", "89.8", "81.2", "", "57.1", "", "2", "1", "", "104", "1", "2", "160", "0", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "91.2", "100.6", "", "", "", "", "98.8"]} +{"pcdb_id": 16620, "brand_name": "Firebird", "model_name": "Silver System", "model_qualifier": "C20kW", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 80.7, "comparative_hot_water_efficiency_pct": 58.9, "output_kw_max": 20.0, "final_year_of_manufacture": 2017, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016620", "000047", "0", "2018/Jan/03 11:52", "Firebird Boilers", "Firebird", "Silver System", "C20kW", "", "2010", "2017", "4", "1", "1", "1", "0", "", "", "2", "2", "1", "15", "20", "", "", "88.5", "80.7", "", "58.9", "", "2", "", "", "201", "1", "1", "38", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "92.2", "95.4", "", "", "", "", "94.8"]} +{"pcdb_id": 16621, "brand_name": "Firebird", "model_name": "Silver System", "model_qualifier": "C26kW", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 80.6, "comparative_hot_water_efficiency_pct": 58.9, "output_kw_max": 26.0, "final_year_of_manufacture": 2017, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016621", "000047", "0", "2018/Jan/03 11:55", "Firebird Boilers", "Firebird", "Silver System", "C26kW", "", "2010", "2017", "4", "1", "1", "1", "0", "", "", "2", "2", "1", "20", "26", "", "", "88.4", "80.6", "", "58.9", "", "2", "", "", "201", "1", "1", "38", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.8", "95.5", "", "", "", "", "94.8"]} +{"pcdb_id": 16622, "brand_name": "Firebird", "model_name": "Silver System", "model_qualifier": "C35kW", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 35.0, "final_year_of_manufacture": 2017, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016622", "000047", "0", "2018/Jan/03 11:56", "Firebird Boilers", "Firebird", "Silver System", "C35kW", "", "2010", "2017", "4", "1", "1", "1", "0", "", "", "2", "2", "1", "26", "35", "", "", "87.9", "80.1", "", "58.5", "", "2", "", "", "201", "1", "1", "38", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.5", "94.4", "", "", "", "", "93.8"]} +{"pcdb_id": 16623, "brand_name": "Firebird", "model_name": "Silver Utility", "model_qualifier": "C20kW", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 80.7, "comparative_hot_water_efficiency_pct": 58.9, "output_kw_max": 20.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016623", "000047", "0", "2012/Mar/27 10:12", "Firebird Boilers", "Firebird", "Silver Utility", "C20kW", "", "2010", "current", "4", "1", "1", "1", "0", "", "", "2", "2", "1", "15", "20", "", "", "88.5", "80.7", "", "58.9", "", "2", "", "", "201", "1", "1", "38", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "92.2", "95.4", "", "", "", "", "94.8"]} +{"pcdb_id": 16624, "brand_name": "Firebird", "model_name": "Silver Utility", "model_qualifier": "C26kW", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 80.6, "comparative_hot_water_efficiency_pct": 58.9, "output_kw_max": 26.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016624", "000047", "0", "2012/Mar/27 10:12", "Firebird Boilers", "Firebird", "Silver Utility", "C26kW", "", "2010", "current", "4", "1", "1", "1", "0", "", "", "2", "2", "1", "20", "26", "", "", "88.4", "80.6", "", "58.9", "", "2", "", "", "201", "1", "1", "38", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.8", "95.5", "", "", "", "", "94.8"]} +{"pcdb_id": 16625, "brand_name": "Firebird", "model_name": "Silver Utility", "model_qualifier": "C35kW", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 35.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016625", "000047", "0", "2012/Mar/27 10:12", "Firebird Boilers", "Firebird", "Silver Utility", "C35kW", "", "2010", "current", "4", "1", "1", "1", "0", "", "", "2", "2", "1", "26", "35", "", "", "87.9", "80.1", "", "58.5", "", "2", "", "", "201", "1", "1", "38", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.5", "94.4", "", "", "", "", "93.8"]} +{"pcdb_id": 16626, "brand_name": "Firebird", "model_name": "Silver Boiilerhouse", "model_qualifier": "C20kW", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 80.7, "comparative_hot_water_efficiency_pct": 58.9, "output_kw_max": 20.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016626", "000047", "0", "2012/Mar/27 10:12", "Firebird Boilers", "Firebird", "Silver Boiilerhouse", "C20kW", "", "2010", "current", "4", "1", "2", "1", "0", "", "", "2", "2", "1", "15", "20", "", "", "88.5", "80.7", "", "58.9", "", "2", "", "", "201", "1", "1", "38", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "92.2", "95.4", "", "", "", "", "94.8"]} +{"pcdb_id": 16627, "brand_name": "Firebird", "model_name": "Silver Boilerhouse", "model_qualifier": "C26kW", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 80.6, "comparative_hot_water_efficiency_pct": 58.9, "output_kw_max": 26.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016627", "000047", "0", "2015/Nov/13 11:01", "Firebird Boilers", "Firebird", "Silver Boilerhouse", "C26kW", "", "2010", "current", "4", "1", "2", "1", "0", "", "", "2", "2", "1", "20", "26", "", "", "88.4", "80.6", "", "58.9", "", "2", "", "", "201", "1", "1", "38", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.8", "95.5", "", "", "", "", "94.8"]} +{"pcdb_id": 16628, "brand_name": "Firebird", "model_name": "Silver Boiilerhouse", "model_qualifier": "C35KW", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 35.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016628", "000047", "0", "2012/Mar/27 10:12", "Firebird Boilers", "Firebird", "Silver Boiilerhouse", "C35KW", "", "2010", "current", "4", "1", "2", "1", "0", "", "", "2", "2", "1", "26", "35", "", "", "87.9", "80.1", "", "58.5", "", "2", "", "", "201", "1", "1", "38", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.5", "94.4", "", "", "", "", "93.8"]} +{"pcdb_id": 16629, "brand_name": "Firebird", "model_name": "Silverpac", "model_qualifier": "C20kW", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 80.7, "comparative_hot_water_efficiency_pct": 58.9, "output_kw_max": 20.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016629", "000047", "0", "2012/Mar/27 10:12", "Firebird Boilers", "Firebird", "Silverpac", "C20kW", "", "2010", "current", "4", "1", "2", "1", "0", "", "", "2", "2", "1", "15", "20", "", "", "88.5", "80.7", "", "58.9", "", "2", "", "", "201", "1", "1", "38", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "92.2", "95.4", "", "", "", "", "94.8"]} +{"pcdb_id": 16630, "brand_name": "Firebird", "model_name": "Silverpac", "model_qualifier": "C26kW", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 80.6, "comparative_hot_water_efficiency_pct": 58.9, "output_kw_max": 26.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016630", "000047", "0", "2012/Mar/27 10:12", "Firebird Boilers", "Firebird", "Silverpac", "C26kW", "", "2010", "current", "4", "1", "2", "1", "0", "", "", "2", "2", "1", "20", "26", "", "", "88.4", "80.6", "", "58.9", "", "2", "", "", "201", "1", "1", "38", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.8", "95.5", "", "", "", "", "94.8"]} +{"pcdb_id": 16631, "brand_name": "Firebird", "model_name": "Silverpac", "model_qualifier": "C35kW", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 35.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016631", "000047", "0", "2012/Mar/27 10:12", "Firebird Boilers", "Firebird", "Silverpac", "C35kW", "", "2010", "current", "4", "1", "2", "1", "0", "", "", "2", "2", "1", "26", "35", "", "", "87.9", "80.1", "", "58.5", "", "2", "", "", "201", "1", "1", "38", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.5", "94.4", "", "", "", "", "93.8"]} +{"pcdb_id": 16632, "brand_name": "i-mini", "model_name": "24", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 62.3, "output_kw_max": 24.2, "final_year_of_manufacture": 2016, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016632", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "i-mini", "24", "", "47-348-77", "2011", "2016", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "88.4", "79.8", "", "62.3", "", "2", "", "", "104", "1", "2", "146", "1", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "", "0035", "", "", "", "", "", "", "", "", "89.8", "96.9", "", "", "", "", "95.6"]} +{"pcdb_id": 16633, "brand_name": "i-mini", "model_name": "30", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 62.3, "output_kw_max": 24.2, "final_year_of_manufacture": 2016, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016633", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "i-mini", "30", "", "47-348-78", "2011", "2016", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "88.4", "79.8", "", "62.3", "", "2", "", "", "104", "1", "2", "152", "1", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "", "0035", "", "", "", "", "", "", "", "", "90.0", "96.9", "", "", "", "", "95.6"]} +{"pcdb_id": 16634, "brand_name": "Ideal", "model_name": "Logic Code Combi", "model_qualifier": "26", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 75.1, "output_kw_max": 24.2, "final_year_of_manufacture": 2013, "subsidiary_type": 1, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0048, "loss_factor_f1_kwh_per_day": 0.92126, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016634", "000008", "3", "2021/Nov/29 20:19", "Ideal Boilers", "Ideal", "Logic Code Combi", "26", "47-348-74", "2011", "2013", "1", "2", "1", "2", "1", "313", "060024", "2", "2", "2", "24.2", "24.2", "", "", "88.4", "87.3", "", "75.1", "", "2", "", "", "104", "1", "2", "146", "1", "0", "", "", "0", "0", "", "", "", "", "1", "7.0133", "0.1547", "0.0048", "0.92126", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.8", "96.9", "", "", "", "", "95.6"]} +{"pcdb_id": 16635, "brand_name": "Ideal", "model_name": "Logic Code Combi", "model_qualifier": "33", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 75.8, "output_kw_max": 24.2, "final_year_of_manufacture": 2013, "subsidiary_type": 1, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0045, "loss_factor_f1_kwh_per_day": 0.86711, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016635", "000008", "3", "2021/Nov/29 20:19", "Ideal Boilers", "Ideal", "Logic Code Combi", "33", "47-348-75", "2011", "2013", "1", "2", "1", "2", "1", "313", "060025", "2", "2", "2", "24.2", "24.2", "", "", "88.4", "87.3", "", "75.8", "", "2", "", "", "104", "1", "2", "152", "1", "0", "", "", "0", "0", "", "", "", "", "1", "6.9512", "0.1528", "0.0045", "0.86711", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.0", "96.9", "", "", "", "", "95.6"]} +{"pcdb_id": 16636, "brand_name": "Ideal", "model_name": "Logic Code Combi", "model_qualifier": "38", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 75.8, "output_kw_max": 24.2, "final_year_of_manufacture": 2013, "subsidiary_type": 1, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0082, "loss_factor_f1_kwh_per_day": 0.83483, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016636", "000008", "3", "2021/Nov/29 20:19", "Ideal Boilers", "Ideal", "Logic Code Combi", "38", "47-348-76", "2011", "2013", "1", "2", "1", "2", "1", "313", "060026", "2", "2", "2", "24.2", "24.2", "", "", "88.3", "87.3", "", "75.8", "", "2", "", "", "104", "1", "2", "177", "1", "0", "", "", "0", "0", "", "", "", "", "1", "6.9449", "0.1539", "0.0082", "0.83483", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.8", "96.9", "", "", "", "", "95.5"]} +{"pcdb_id": 16637, "brand_name": "Vokera", "model_name": "Compact", "model_qualifier": "25", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 86.6, "comparative_hot_water_efficiency_pct": 72.0, "output_kw_max": 19.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.003, "loss_factor_f1_kwh_per_day": 1.17113, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016637", "000011", "0", "2012/Sep/19 14:28", "Vokera", "Vokera", "Compact", "25", "4736401", "2010", "current", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "19.5", "19.5", "", "", "88.4", "86.6", "", "72.0", "", "2", "", "", "104", "1", "2", "123", "4.5", "0", "", "", "0", "0", "", "", "", "", "1", "7.315", "0.105", "0.003", "1.17113", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "97.8", "", "", "", "", "95.9"]} +{"pcdb_id": 16638, "brand_name": "Glow-worm", "model_name": "Ultracom 2 35 Store", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 86.8, "comparative_hot_water_efficiency_pct": 59.2, "output_kw_max": 30.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0009, "loss_factor_f1_kwh_per_day": 2.70975, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016638", "000207", "0", "2014/May/02 14:44", "Glow-worm", "Glow-worm", "Ultracom 2 35 Store", "", "GC No 47-019-15", "2011", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "30", "30", "", "", "88.4", "86.8", "", "59.2", "", "2", "", "", "106", "1", "2", "68", "7.1", "2", "", "0", "40", "0", "7", "2", "60", "", "1", "8.89", "0.263", "0.0009", "2.70975", "", "", "", "", "", "", "", "", "0085", "", "", "", "", "", "", "", "", "88.2", "97.8", "", "", "", "", "96.0"]} +{"pcdb_id": 16639, "brand_name": "Glow-worm", "model_name": "Ultracom 2 35 Store", "model_qualifier": "", "winter_efficiency_pct": 89.5, "summer_efficiency_pct": 82.2, "comparative_hot_water_efficiency_pct": 35.5, "output_kw_max": 30.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016639", "000207", "0", "2024/Jan/31 10:17", "Glow-worm", "Glow-worm", "Ultracom 2 35 Store", "", "", "2011", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "30", "30", "", "", "89.5", "82.2", "", "35.5", "", "2", "1", "", "106", "1", "2", "68", "7.1", "2", "", "0", "40", "0", "7", "2", "60", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.2", "100.0", "", "", "", "", "98.1"]} +{"pcdb_id": 16640, "brand_name": "Remeha", "model_name": "Quinta Pro 30", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 32.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016640", "000006", "0", "2012/Mar/27 10:12", "Broag Remeha", "Remeha", "Quinta Pro 30", "", "", "2010", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "32", "32", "", "", "88.1", "79.1", "", "57.8", "", "2", "", "", "102", "1", "2", "39", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "97.0", "", "", "", "", "95.3"]} +{"pcdb_id": 16642, "brand_name": "Heatline", "model_name": "CaprizPlus", "model_qualifier": "28", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 56.0, "output_kw_max": 23.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016642", "000215", "0", "2011/Feb/22 12:50", "Heatline", "Heatline", "CaprizPlus", "28", "GCN 47-157-20", "2001", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "23.4", "23.4", "", "", "88.2", "79.6", "", "56.0", "", "2", "", "", "104", "1", "2", "130", "3", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "97.3", "", "", "", "", "95.5"]} +{"pcdb_id": 16643, "brand_name": "Heatline", "model_name": "CaprizPlus", "model_qualifier": "24", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 56.0, "output_kw_max": 17.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016643", "000215", "0", "2011/Feb/22 12:50", "Heatline", "Heatline", "CaprizPlus", "24", "GCN 47-157-19", "2011", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "17.6", "17.6", "", "", "88.3", "79.7", "", "56.0", "", "2", "", "", "104", "1", "2", "130", "3", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "97.6", "", "", "", "", "95.7"]} +{"pcdb_id": 16644, "brand_name": "Heatline", "model_name": "Monza", "model_qualifier": "28", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 56.0, "output_kw_max": 23.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016644", "000215", "0", "2011/Feb/22 12:50", "Heatline", "Heatline", "Monza", "28", "GCN 47-157-22", "2011", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "23.4", "23.4", "", "", "88.2", "79.6", "", "56.0", "", "2", "", "", "104", "1", "2", "130", "3", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "97.3", "", "", "", "", "95.5"]} +{"pcdb_id": 16645, "brand_name": "Heatline", "model_name": "Monza", "model_qualifier": "24", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 56.0, "output_kw_max": 17.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016645", "000215", "0", "2011/Feb/22 12:51", "Heatline", "Heatline", "Monza", "24", "GCN 47-157-21", "2011", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "17.6", "17.6", "", "", "88.3", "79.7", "", "56.0", "", "2", "", "", "104", "1", "2", "130", "3", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "97.6", "", "", "", "", "95.7"]} +{"pcdb_id": 16646, "brand_name": "Vokera", "model_name": "Linea", "model_qualifier": "One", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 56.3, "output_kw_max": 29.34, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016646", "000011", "0", "2014/Oct/15 11:21", "Vokera", "Vokera", "Linea", "One", "4736403", "2010", "current", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "29.34", "29.34", "", "", "88.6", "80.0", "", "56.3", "", "2", "", "", "104", "1", "2", "153", "4.5", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "", "", "", "", "88.1", "98.3", "", "", "", "", "96.4"]} +{"pcdb_id": 16647, "brand_name": "Vokera", "model_name": "Compact", "model_qualifier": "29", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 86.7, "comparative_hot_water_efficiency_pct": 71.9, "output_kw_max": 24.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.003, "loss_factor_f1_kwh_per_day": 1.18314, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016647", "000011", "0", "2012/Sep/27 08:46", "Vokera", "Vokera", "Compact", "29", "4736402", "2010", "current", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "24.4", "24.4", "", "", "88.3", "86.7", "", "71.9", "", "2", "", "", "104", "1", "2", "128", "4.5", "0", "", "", "", "0", "", "", "", "", "1", "7.325", "0.103", "0.003", "1.18314", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "97.6", "", "", "", "", "95.7"]} +{"pcdb_id": 16648, "brand_name": "Ferroli", "model_name": "DOMIcondens HE", "model_qualifier": "26C", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 86.6, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 24.4, "final_year_of_manufacture": 2017, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0049, "loss_factor_f1_kwh_per_day": 2.8838, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016648", "000097", "0", "2017/Aug/07 17:02", "Ferroli", "Ferroli", "DOMIcondens HE", "26C", "", "2011", "2017", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.4", "24.4", "", "", "87.9", "86.6", "", "57.8", "", "2", "", "", "104", "1", "2", "135", "2.0", "0", "", "", "", "0", "", "", "", "", "1", "9.1075", "0.0699", "0.0049", "2.8838", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "96.5", "", "", "", "", "94.9"]} +{"pcdb_id": 16649, "brand_name": "Ferroli", "model_name": "DOMIcondens HE", "model_qualifier": "26C", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 56.4, "output_kw_max": 24.4, "final_year_of_manufacture": 2017, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016649", "000097", "0", "2017/Aug/21 13:40", "Ferroli", "Ferroli", "DOMIcondens HE", "26C", "", "2011", "2017", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24.4", "24.4", "", "", "88.9", "80.3", "", "56.4", "", "2", "1", "", "104", "1", "2", "135", "2.0", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.8", "98.6", "", "", "", "", "97.0"]} +{"pcdb_id": 16650, "brand_name": "Vokera", "model_name": "Unica", "model_qualifier": "36HE", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 55.9, "output_kw_max": 29.31, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016650", "000011", "0", "2011/Mar/24 12:36", "Vokera", "Vokera", "Unica", "36HE", "4709487", "2006", "current", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "29.31", "29.31", "", "", "88.1", "79.5", "", "55.9", "", "2", "", "", "104", "1", "2", "150", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "97.1", "", "", "", "", "95.4"]} +{"pcdb_id": 16651, "brand_name": "GEM", "model_name": "E-Compact 50/70", "model_qualifier": "Cosyman", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 81.4, "comparative_hot_water_efficiency_pct": 59.5, "output_kw_max": 22.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016651", "000260", "0", "2012/Mar/27 10:12", "GEM Heating Products", "GEM", "E-Compact 50/70", "Cosyman", "", "2007", "current", "4", "1", "2", "1", "0", "", "", "2", "3", "2", "15", "22.3", "", "", "89.2", "81.4", "", "59.5", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.3", "97.7", "", "", "", "", "96.5"]} +{"pcdb_id": 16652, "brand_name": "GEM", "model_name": "E-Compact 50/70", "model_qualifier": "Boiler House", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 81.4, "comparative_hot_water_efficiency_pct": 59.5, "output_kw_max": 22.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016652", "000260", "0", "2012/Mar/27 10:12", "GEM Heating Products", "GEM", "E-Compact 50/70", "Boiler House", "", "2007", "current", "4", "1", "2", "1", "0", "", "", "2", "3", "2", "15", "22.3", "", "", "89.2", "81.4", "", "59.5", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.3", "97.7", "", "", "", "", "96.5"]} +{"pcdb_id": 16653, "brand_name": "GEM", "model_name": "E-Compact 70/90", "model_qualifier": "Boiler House", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 59.2, "output_kw_max": 27.9, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016653", "000260", "0", "2012/Mar/27 10:12", "GEM Heating Products", "GEM", "E-Compact 70/90", "Boiler House", "", "2007", "current", "4", "1", "2", "1", "0", "", "", "2", "3", "2", "20", "27.9", "", "", "88.8", "81.0", "", "59.2", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "89.5", "97.4", "", "", "", "", "95.9"]} +{"pcdb_id": 16654, "brand_name": "GEM", "model_name": "E-Compact 70/90", "model_qualifier": "Cosyman", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 59.2, "output_kw_max": 27.9, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016654", "000260", "0", "2012/Mar/27 10:12", "GEM Heating Products", "GEM", "E-Compact 70/90", "Cosyman", "", "2007", "current", "4", "1", "2", "1", "0", "", "", "2", "3", "2", "20", "27.9", "", "", "88.8", "81.0", "", "59.2", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "89.5", "97.4", "", "", "", "", "95.9"]} +{"pcdb_id": 16655, "brand_name": "Alpha", "model_name": "InTec 28S", "model_qualifier": "", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 28.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016655", "000001", "0", "2013/May/24 12:32", "Alpha Therm", "Alpha", "InTec 28S", "", "", "2011", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "28", "28", "", "", "88.2", "79.2", "", "57.8", "", "2", "", "", "102", "1", "2", "125", "6", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.8", "96.9", "", "", "", "", "95.3"]} +{"pcdb_id": 16656, "brand_name": "Alpha", "model_name": "InTec 28S", "model_qualifier": "", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 28.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016656", "000001", "0", "2013/Mar/28 08:26", "Alpha Therm", "Alpha", "InTec 28S", "", "", "2011", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "28", "28", "", "", "89.2", "80.2", "", "58.6", "", "2", "1", "", "102", "1", "2", "125", "6", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.8", "99.0", "", "", "", "", "97.5"]} +{"pcdb_id": 16657, "brand_name": "Alpha", "model_name": "InTec 18S", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 18.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016657", "000001", "0", "2013/Mar/28 08:26", "Alpha Therm", "Alpha", "InTec 18S", "", "", "2011", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18.3", "18.3", "", "", "88.6", "79.6", "", "58.1", "", "2", "", "", "102", "1", "2", "115", "6", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.5", "98.1", "", "", "", "", "96.3"]} +{"pcdb_id": 16658, "brand_name": "Alpha", "model_name": "InTec 18S", "model_qualifier": "", "winter_efficiency_pct": 89.6, "summer_efficiency_pct": 80.6, "comparative_hot_water_efficiency_pct": 58.9, "output_kw_max": 18.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016658", "000001", "0", "2013/Mar/28 08:26", "Alpha Therm", "Alpha", "InTec 18S", "", "", "2011", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "18.3", "18.3", "", "", "89.6", "80.6", "", "58.9", "", "2", "1", "", "102", "1", "2", "115", "6", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.4", "100.3", "", "", "", "", "98.4"]} +{"pcdb_id": 16659, "brand_name": "Alpha", "model_name": "InTec 12S", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 12.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016659", "000001", "0", "2013/Mar/28 08:26", "Alpha Therm", "Alpha", "InTec 12S", "", "", "2011", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "12", "12", "", "", "88.1", "79.1", "", "57.7", "", "2", "", "", "102", "1", "2", "115", "6", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "97.0", "", "", "", "", "95.3"]} +{"pcdb_id": 16660, "brand_name": "Alpha", "model_name": "InTec 12S", "model_qualifier": "", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 12.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016660", "000001", "0", "2013/Mar/28 08:26", "Alpha Therm", "Alpha", "InTec 12S", "", "", "2011", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "12", "12", "", "", "89.1", "80.1", "", "58.5", "", "2", "1", "", "102", "1", "2", "115", "6", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.7", "99.2", "", "", "", "", "97.4"]} +{"pcdb_id": 16661, "brand_name": "Alpha", "model_name": "InTec 34C", "model_qualifier": "", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 87.0, "comparative_hot_water_efficiency_pct": 76.8, "output_kw_max": 28.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0029, "loss_factor_f1_kwh_per_day": 0.75503, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016661", "000001", "0", "2016/Sep/20 00:00", "Alpha Therm", "Alpha", "InTec 34C", "", "", "2011", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28", "28", "", "", "88.2", "87.0", "", "76.8", "", "2", "", "", "104", "1", "2", "125", "6", "0", "", "", "", "0", "", "", "", "", "1", "6.856", "0.14", "0.0029", "0.75503", "", "", "", "", "", "", "", "", "1005", "", "", "", "", "", "", "", "", "88.8", "96.9", "", "", "", "", "95.3"]} +{"pcdb_id": 16662, "brand_name": "Alpha", "model_name": "InTec 34C", "model_qualifier": "", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 80.6, "comparative_hot_water_efficiency_pct": 56.7, "output_kw_max": 28.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016662", "000001", "0", "2016/Sep/20 00:00", "Alpha Therm", "Alpha", "InTec 34C", "", "", "2011", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "28", "28", "", "", "89.2", "80.6", "", "56.7", "", "2", "1", "", "104", "1", "2", "125", "6", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "1005", "", "", "", "", "", "", "", "", "90.8", "99.0", "", "", "", "", "97.5"]} +{"pcdb_id": 16663, "brand_name": "Alpha", "model_name": "InTec 30C", "model_qualifier": "", "winter_efficiency_pct": 87.6, "summer_efficiency_pct": 86.9, "comparative_hot_water_efficiency_pct": 74.8, "output_kw_max": 24.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0049, "loss_factor_f1_kwh_per_day": 0.91795, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016663", "000001", "0", "2016/Sep/20 00:00", "Alpha Therm", "Alpha", "InTec 30C", "", "", "2011", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.0", "24.0", "", "", "87.6", "86.9", "", "74.8", "", "2", "", "", "104", "1", "2", "120", "6", "0", "", "", "", "0", "", "", "", "", "1", "7.039", "0.15", "0.0049", "0.91795", "", "", "", "", "", "", "", "", "1005", "", "", "", "", "", "", "", "", "88.7", "95.5", "", "", "", "", "94.2"]} +{"pcdb_id": 16664, "brand_name": "Alpha", "model_name": "InTec 30C", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 56.3, "output_kw_max": 24.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016664", "000001", "0", "2016/Sep/20 00:00", "Alpha Therm", "Alpha", "InTec 30C", "", "", "2011", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24.0", "24.0", "", "", "88.6", "80.0", "", "56.3", "", "2", "1", "", "104", "1", "2", "120", "6", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "1005", "", "", "", "", "", "", "", "", "90.7", "97.6", "", "", "", "", "96.3"]} +{"pcdb_id": 16665, "brand_name": "Alpha", "model_name": "InTec 26C", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 86.8, "comparative_hot_water_efficiency_pct": 76.6, "output_kw_max": 18.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0025, "loss_factor_f1_kwh_per_day": 0.76768, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016665", "000001", "0", "2011/Oct/28 08:07", "Alpha Therm", "Alpha", "InTec 26C", "", "", "2011", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "18.3", "18.3", "", "", "88.6", "86.8", "", "76.6", "", "2", "", "", "104", "1", "2", "115", "6", "0", "", "", "", "0", "", "", "", "", "1", "6.876", "0.14", "0.0025", "0.76768", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.5", "98.1", "", "", "", "", "96.3"]} +{"pcdb_id": 16666, "brand_name": "Alpha", "model_name": "InTec 26C", "model_qualifier": "", "winter_efficiency_pct": 89.6, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 57.0, "output_kw_max": 18.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016666", "000001", "0", "2013/Apr/08 09:44", "Alpha Therm", "Alpha", "InTec 26C", "", "", "2011", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "18.3", "18.3", "", "", "89.6", "81.0", "", "57.0", "", "2", "1", "", "104", "1", "2", "115", "6", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.4", "100.3", "", "", "", "", "98.4"]} +{"pcdb_id": 16667, "brand_name": "Alpha", "model_name": "InTec 24X", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 86.8, "comparative_hot_water_efficiency_pct": 75.4, "output_kw_max": 18.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.004, "loss_factor_f1_kwh_per_day": 0.86204, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016667", "000001", "0", "2011/Jul/28 11:07", "Alpha Therm", "Alpha", "InTec 24X", "", "", "2011", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "18.3", "18.3", "", "", "88.6", "86.8", "", "75.4", "", "2", "", "", "104", "1", "2", "115", "6", "0", "", "", "", "0", "", "", "", "", "1", "6.983", "0.13", "0.004", "0.86204", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.5", "98.1", "", "", "", "", "96.3"]} +{"pcdb_id": 16668, "brand_name": "Alpha", "model_name": "InTec 24X", "model_qualifier": "", "winter_efficiency_pct": 89.6, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 57.0, "output_kw_max": 18.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016668", "000001", "0", "2013/Apr/08 09:44", "Alpha Therm", "Alpha", "InTec 24X", "", "", "2011", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "18.3", "18.3", "", "", "89.6", "81.0", "", "57.0", "", "2", "1", "", "104", "1", "2", "115", "6", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.4", "100.3", "", "", "", "", "98.4"]} +{"pcdb_id": 16669, "brand_name": "Alpha", "model_name": "InTec 28X", "model_qualifier": "", "winter_efficiency_pct": 87.6, "summer_efficiency_pct": 86.9, "comparative_hot_water_efficiency_pct": 77.2, "output_kw_max": 24.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0025, "loss_factor_f1_kwh_per_day": 0.72165, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016669", "000001", "0", "2011/Jul/28 11:08", "Alpha Therm", "Alpha", "InTec 28X", "", "", "2011", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "87.6", "86.9", "", "77.2", "", "2", "", "", "104", "1", "2", "120", "6", "0", "", "", "", "0", "", "", "", "", "1", "6.821", "0.15", "0.0025", "0.72165", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.7", "95.5", "", "", "", "", "94.2"]} +{"pcdb_id": 16670, "brand_name": "Alpha", "model_name": "InTec 28X", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 56.3, "output_kw_max": 24.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016670", "000001", "0", "2013/Apr/08 09:44", "Alpha Therm", "Alpha", "InTec 28X", "", "", "2011", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "88.6", "80.0", "", "56.3", "", "2", "1", "", "104", "1", "2", "120", "6", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.7", "97.6", "", "", "", "", "96.3"]} +{"pcdb_id": 16673, "brand_name": "Ariston", "model_name": "E-System 24", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 21.6, "final_year_of_manufacture": 2013, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016673", "000080", "0", "2013/Nov/04 15:27", "Ariston Thermo UK", "Ariston", "E-System 24", "", "", "2010", "2013", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "21.6", "21.6", "", "", "88.3", "79.3", "", "57.9", "", "2", "", "", "102", "1", "2", "120", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "97.3", "", "", "", "", "95.6"]} +{"pcdb_id": 16674, "brand_name": "Ariston", "model_name": "E-System 30", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 27.4, "final_year_of_manufacture": 2013, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016674", "000080", "0", "2013/Nov/04 15:27", "Ariston Thermo UK", "Ariston", "E-System 30", "", "", "2010", "2013", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "27.4", "27.4", "", "", "88.3", "79.3", "", "57.9", "", "2", "", "", "102", "1", "2", "120", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "97.5", "", "", "", "", "95.7"]} +{"pcdb_id": 16675, "brand_name": "Baxi", "model_name": "Megaflo 2 System", "model_qualifier": "28 Compact GA", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 28.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016675", "000005", "0", "2015/Aug/06 12:01", "Baxi Heating UK", "Baxi", "Megaflo 2 System", "28 Compact GA", "GC No 41-075-74", "2011", "2015", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "28", "28", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "135", "3.5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "90.0", "96.9", "", "", "", "", "95.6"]} +{"pcdb_id": 16676, "brand_name": "Baxi", "model_name": "Megaflo 2 System", "model_qualifier": "32 Compact GA", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 32.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016676", "000005", "0", "2015/Aug/06 11:59", "Baxi Heating UK", "Baxi", "Megaflo 2 System", "32 Compact GA", "GC No 41-075-75", "2011", "2015", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "32", "32", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "132", "3.5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "90.0", "96.9", "", "", "", "", "95.6"]} +{"pcdb_id": 16677, "brand_name": "Baxi", "model_name": "Megaflo 2 System", "model_qualifier": "24 Compact GA", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 24.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016677", "000005", "0", "2015/Aug/06 12:01", "Baxi Heating UK", "Baxi", "Megaflo 2 System", "24 Compact GA", "41-075-73", "2011", "2015", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24", "24", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "104", "3.5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "90.0", "96.9", "", "", "", "", "95.6"]} +{"pcdb_id": 16679, "brand_name": "Baxi", "model_name": "Megaflo 2 System", "model_qualifier": "18 Compact GA", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 18.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016679", "000005", "0", "2015/Aug/06 12:02", "Baxi Heating UK", "Baxi", "Megaflo 2 System", "18 Compact GA", "GC No 41-075-72", "2011", "2015", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18", "18", "", "", "88.2", "79.2", "", "57.8", "", "2", "", "", "102", "1", "2", "125", "3.5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "90.0", "96.4", "", "", "", "", "95.2"]} +{"pcdb_id": 16680, "brand_name": "Baxi", "model_name": "Megaflo 2 System", "model_qualifier": "15 Compact GA", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 15.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016680", "000005", "0", "2015/Aug/06 12:03", "Baxi Heating UK", "Baxi", "Megaflo 2 System", "15 Compact GA", "GC No 41-075-71", "2011", "2015", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "15", "15", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "108", "3.5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "90.0", "97.0", "", "", "", "", "95.7"]} +{"pcdb_id": 16681, "brand_name": "Baxi", "model_name": "Megaflo 2 System", "model_qualifier": "12 Compact GA", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 12.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016681", "000005", "0", "2015/Aug/06 12:04", "Baxi Heating UK", "Baxi", "Megaflo 2 System", "12 Compact GA", "GC No 41-075-70", "2011", "2015", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "12", "12", "", "", "88.5", "79.5", "", "58.0", "", "2", "", "", "102", "1", "2", "110", "3.5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "90.0", "97.1", "", "", "", "", "95.8"]} +{"pcdb_id": 16682, "brand_name": "Baxi", "model_name": "Neta-tec Combi", "model_qualifier": "33 GA", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 77.2, "output_kw_max": 28.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0045, "loss_factor_f1_kwh_per_day": 0.74098, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016682", "000005", "0", "2015/Aug/06 12:04", "Baxi Heating UK", "Baxi", "Neta-tec Combi", "33 GA", "GC No 47-075-53", "2011", "2015", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28", "28", "", "", "88.4", "87.3", "", "77.2", "", "2", "", "", "104", "1", "2", "133", "3.5", "0", "", "", "", "0", "", "", "", "", "1", "6.821", "0.106", "0.0045", "0.74098", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "90.0", "97.0", "", "", "", "", "95.7"]} +{"pcdb_id": 16683, "brand_name": "Baxi", "model_name": "Neta-tec Combi", "model_qualifier": "28 GA", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 77.3, "output_kw_max": 24.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0044, "loss_factor_f1_kwh_per_day": 0.73349, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016683", "000005", "0", "2015/Aug/06 12:05", "Baxi Heating UK", "Baxi", "Neta-tec Combi", "28 GA", "GC No 47-075-52", "2011", "2015", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "88.4", "87.3", "", "77.3", "", "2", "", "", "104", "1", "2", "116", "3.5", "0", "", "", "", "0", "", "", "", "", "1", "6.813", "0.118", "0.0044", "0.73349", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "90.0", "96.9", "", "", "", "", "95.6"]} +{"pcdb_id": 16684, "brand_name": "Baxi", "model_name": "Neta-tec Combi", "model_qualifier": "24 GA", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 77.6, "output_kw_max": 20.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0043, "loss_factor_f1_kwh_per_day": 0.70793, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016684", "000005", "0", "2015/Aug/06 12:05", "Baxi Heating UK", "Baxi", "Neta-tec Combi", "24 GA", "GC No 47-075-51", "2011", "2015", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "20", "20", "", "", "88.4", "87.3", "", "77.6", "", "2", "", "", "104", "1", "2", "104", "3.5", "0", "", "", "", "0", "", "", "", "", "1", "6.786", "0.118", "0.0043", "0.70793", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "90.0", "96.9", "", "", "", "", "95.6"]} +{"pcdb_id": 16685, "brand_name": "Baxi", "model_name": "Duo-tec 2 Combi", "model_qualifier": "40 GA", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 77.8, "output_kw_max": 32.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0036, "loss_factor_f1_kwh_per_day": 0.69163, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016685", "000005", "0", "2015/Aug/06 12:06", "Baxi Heating UK", "Baxi", "Duo-tec 2 Combi", "40 GA", "GC No 47-075-57", "2011", "2015", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "32", "32", "", "", "88.4", "87.3", "", "77.8", "", "2", "", "", "104", "1", "2", "142", "3.5", "0", "", "", "", "0", "", "", "", "", "1", "6.765", "0.111", "0.0036", "0.69163", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "90.0", "96.9", "", "", "", "", "95.6"]} +{"pcdb_id": 16686, "brand_name": "Baxi", "model_name": "Duo-tec 2 Combi", "model_qualifier": "24 GA", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 77.6, "output_kw_max": 20.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0043, "loss_factor_f1_kwh_per_day": 0.70793, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016686", "000005", "0", "2015/Aug/06 12:06", "Baxi Heating UK", "Baxi", "Duo-tec 2 Combi", "24 GA", "GC No 41-075-54", "2011", "2015", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "20", "20", "", "", "88.4", "87.3", "", "77.6", "", "2", "", "", "104", "1", "2", "104", "3.5", "0", "", "", "", "0", "", "", "", "", "1", "6.786", "0.118", "0.0043", "0.70793", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "90.0", "96.9", "", "", "", "", "95.6"]} +{"pcdb_id": 16687, "brand_name": "Baxi", "model_name": "Duo-tec 2 Combi", "model_qualifier": "28 GA", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 77.3, "output_kw_max": 24.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0044, "loss_factor_f1_kwh_per_day": 0.73349, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016687", "000005", "0", "2015/Aug/06 12:07", "Baxi Heating UK", "Baxi", "Duo-tec 2 Combi", "28 GA", "GC No 41-075-55", "2011", "2015", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "88.4", "87.3", "", "77.3", "", "2", "", "", "104", "1", "2", "116", "3.5", "0", "", "", "", "0", "", "", "", "", "1", "6.813", "0.118", "0.0044", "0.73349", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "90.0", "96.9", "", "", "", "", "95.6"]} +{"pcdb_id": 16688, "brand_name": "Baxi", "model_name": "Duo-tec 2 Combi", "model_qualifier": "33 GA", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 77.2, "output_kw_max": 28.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0045, "loss_factor_f1_kwh_per_day": 0.74098, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016688", "000005", "0", "2015/Aug/06 12:07", "Baxi Heating UK", "Baxi", "Duo-tec 2 Combi", "33 GA", "GC No. 47-075-56", "2011", "2015", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28", "28", "", "", "88.4", "87.3", "", "77.2", "", "2", "", "", "104", "1", "2", "132", "3.5", "0", "", "", "", "0", "", "", "", "", "1", "6.821", "0.106", "0.0045", "0.74098", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "90.0", "97.0", "", "", "", "", "95.7"]} +{"pcdb_id": 16689, "brand_name": "Unical", "model_name": "Alkon C 28 HE", "model_qualifier": "", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 56.3, "output_kw_max": 27.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016689", "000263", "0", "2011/Sep/28 09:21", "Unical AG", "Unical", "Alkon C 28 HE", "", "41010159GB", "2011", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "27.3", "27.3", "", "", "88.7", "80.1", "", "56.3", "", "2", "", "", "104", "1", "2", "133", "4", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "98.5", "", "", "", "", "96.5"]} +{"pcdb_id": 16690, "brand_name": "Unical", "model_name": "Alkon R 28 HE", "model_qualifier": "", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 27.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016690", "000263", "0", "2012/Mar/27 10:12", "Unical AG", "Unical", "Alkon R 28 HE", "", "41010181GB", "2011", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "27.3", "27.3", "", "", "88.7", "79.7", "", "58.2", "", "2", "", "", "102", "1", "2", "130", "4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "98.5", "", "", "", "", "96.5"]} +{"pcdb_id": 16691, "brand_name": "Unical", "model_name": "Alkon R 35 HE", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 33.8, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016691", "000263", "0", "2012/Mar/27 10:12", "Unical AG", "Unical", "Alkon R 35 HE", "", "41010182GB", "2011", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "33.8", "33.8", "", "", "88.8", "79.8", "", "58.3", "", "2", "", "", "102", "1", "2", "130", "4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.2", "98.7", "", "", "", "", "96.7"]} +{"pcdb_id": 16692, "brand_name": "Unical", "model_name": "Alkon C 35 HE", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 56.4, "output_kw_max": 33.8, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016692", "000263", "0", "2011/Sep/28 09:26", "Unical AG", "Unical", "Alkon C 35 HE", "", "41010160GB", "2011", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "33.8", "33.8", "", "", "88.8", "80.2", "", "56.4", "", "2", "", "", "104", "1", "2", "133", "4", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.2", "98.7", "", "", "", "", "96.7"]} +{"pcdb_id": 16693, "brand_name": "Vokera", "model_name": "Mynute", "model_qualifier": "25A", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 24.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016693", "000011", "0", "2012/Mar/27 10:12", "Vokera", "Vokera", "Mynute", "25A", "41 094 72", "2010", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "24.4", "24.4", "", "", "88.3", "79.3", "", "57.9", "", "2", "", "", "102", "1", "2", "128", "4.5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "97.6", "", "", "", "", "95.7"]} +{"pcdb_id": 16694, "brand_name": "Biasi", "model_name": "Riva Plus HE", "model_qualifier": "M296.24SM/C", "winter_efficiency_pct": 87.4, "summer_efficiency_pct": 86.6, "comparative_hot_water_efficiency_pct": 67.4, "output_kw_max": 24.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.005, "loss_factor_f1_kwh_per_day": 1.63862, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016694", "000208", "0", "2011/Jun/20 11:20", "Biasi UK", "Biasi", "Riva Plus HE", "M296.24SM/C", "47-583-24", "2011", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.4", "24.4", "", "", "87.4", "86.6", "", "67.4", "", "2", "", "", "104", "1", "2", "140", "3", "0", "", "", "", "0", "", "", "", "", "1", "7.816", "0.131", "0.005", "1.63862", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "95.4", "", "", "", "", "94.0"]} +{"pcdb_id": 16695, "brand_name": "Biasi", "model_name": "Riva Plus HE", "model_qualifier": "M296.24SM/C", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 56.1, "output_kw_max": 24.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016695", "000208", "0", "2013/Apr/08 09:45", "Biasi UK", "Biasi", "Riva Plus HE", "M296.24SM/C", "", "2011", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24.4", "24.4", "", "", "88.4", "79.8", "", "56.1", "", "2", "1", "", "104", "1", "2", "140", "3", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.7", "97.5", "", "", "", "", "96.0"]} +{"pcdb_id": 16696, "brand_name": "Biasi", "model_name": "Riva Plus HE", "model_qualifier": "M296.28SM/C", "winter_efficiency_pct": 87.4, "summer_efficiency_pct": 86.7, "comparative_hot_water_efficiency_pct": 68.0, "output_kw_max": 28.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.013, "loss_factor_f1_kwh_per_day": 1.53602, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016696", "000208", "0", "2011/Jun/20 11:22", "Biasi UK", "Biasi", "Riva Plus HE", "M296.28SM/C", "47-583-25", "2011", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28.3", "28.3", "", "", "87.4", "86.7", "", "68.0", "", "2", "", "", "104", "1", "2", "150", "3", "0", "", "", "", "0", "", "", "", "", "1", "7.75", "0.137", "0.013", "1.53602", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "95.2", "", "", "", "", "93.9"]} +{"pcdb_id": 16697, "brand_name": "Biasi", "model_name": "Riva Plus HE", "model_qualifier": "M296.28SM/C", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 56.1, "output_kw_max": 28.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016697", "000208", "0", "2013/Apr/08 09:45", "Biasi UK", "Biasi", "Riva Plus HE", "M296.28SM/C", "", "2011", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "28.3", "28.3", "", "", "88.4", "79.8", "", "56.1", "", "2", "1", "", "104", "1", "2", "150", "3", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.0", "97.3", "", "", "", "", "95.9"]} +{"pcdb_id": 16698, "brand_name": "Biasi", "model_name": "Riva Plus HE", "model_qualifier": "M296.24SR/C", "winter_efficiency_pct": 87.4, "summer_efficiency_pct": 78.4, "comparative_hot_water_efficiency_pct": 57.3, "output_kw_max": 24.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016698", "000208", "0", "2012/Mar/27 10:12", "Biasi UK", "Biasi", "Riva Plus HE", "M296.24SR/C", "41-583-18", "2011", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24.4", "24.4", "", "", "87.4", "78.4", "", "57.3", "", "2", "", "", "102", "1", "2", "140", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "95.4", "", "", "", "", "94.0"]} +{"pcdb_id": 16699, "brand_name": "Biasi", "model_name": "Riva Plus HE", "model_qualifier": "M296.24SR/C", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 24.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016699", "000208", "0", "2012/Mar/27 10:12", "Biasi UK", "Biasi", "Riva Plus HE", "M296.24SR/C", "", "2011", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "24.4", "24.4", "", "", "88.4", "79.4", "", "58.0", "", "2", "1", "", "102", "1", "2", "140", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.7", "97.5", "", "", "", "", "96.0"]} +{"pcdb_id": 16700, "brand_name": "Biasi", "model_name": "Riva Plus HE", "model_qualifier": "M296.28SR/C", "winter_efficiency_pct": 87.4, "summer_efficiency_pct": 78.4, "comparative_hot_water_efficiency_pct": 57.3, "output_kw_max": 28.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016700", "000208", "0", "2012/Mar/27 10:12", "Biasi UK", "Biasi", "Riva Plus HE", "M296.28SR/C", "41-583-19", "2011", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "28.3", "28.3", "", "", "87.4", "78.4", "", "57.3", "", "2", "", "", "102", "1", "2", "150", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "95.2", "", "", "", "", "93.9"]} +{"pcdb_id": 16701, "brand_name": "Biasi", "model_name": "Riva Plus HE", "model_qualifier": "M296.28SR/C", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 28.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016701", "000208", "0", "2012/Mar/27 10:12", "Biasi UK", "Biasi", "Riva Plus HE", "M296.28SR/C", "", "2011", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "28.3", "28.3", "", "", "88.4", "79.4", "", "58.0", "", "2", "1", "", "102", "1", "2", "150", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.0", "97.3", "", "", "", "", "95.9"]} +{"pcdb_id": 16702, "brand_name": "Baxi", "model_name": "Neta-tec Combi", "model_qualifier": "24 GA", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 56.8, "output_kw_max": 20.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016702", "000005", "0", "2013/Apr/08 09:50", "Baxi Heating UK", "Baxi", "Neta-tec Combi", "24 GA", "", "2011", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "20", "20", "", "", "89.4", "80.8", "", "56.8", "", "2", "1", "", "104", "1", "2", "104", "3.5", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "92.0", "99.1", "", "", "", "", "97.8"]} +{"pcdb_id": 16703, "brand_name": "Baxi", "model_name": "Neta-tec Combi", "model_qualifier": "28 GA", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 56.8, "output_kw_max": 24.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016703", "000005", "0", "2013/Apr/08 09:50", "Baxi Heating UK", "Baxi", "Neta-tec Combi", "28 GA", "", "2011", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "89.4", "80.8", "", "56.8", "", "2", "1", "", "104", "1", "2", "116", "3.5", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "92.0", "99.1", "", "", "", "", "97.8"]} +{"pcdb_id": 16704, "brand_name": "Baxi", "model_name": "Neta-tec Combi", "model_qualifier": "33 GA", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 56.8, "output_kw_max": 28.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016704", "000005", "0", "2013/Apr/08 09:50", "Baxi Heating UK", "Baxi", "Neta-tec Combi", "33 GA", "", "2011", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "28", "28", "", "", "89.4", "80.8", "", "56.8", "", "2", "1", "", "104", "1", "2", "133", "3.5", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "92.0", "99.2", "", "", "", "", "97.8"]} +{"pcdb_id": 16705, "brand_name": "Baxi", "model_name": "Duo-tec 2 Combi", "model_qualifier": "24 GA", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 56.8, "output_kw_max": 20.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016705", "000005", "0", "2013/Apr/08 09:51", "Baxi Heating UK", "Baxi", "Duo-tec 2 Combi", "24 GA", "", "2011", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "20", "20", "", "", "89.4", "80.8", "", "56.8", "", "2", "1", "", "104", "1", "2", "104", "3.5", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "92.0", "99.1", "", "", "", "", "97.8"]} +{"pcdb_id": 16706, "brand_name": "Baxi", "model_name": "Duo-tec 2 Combi", "model_qualifier": "28 GA", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 56.8, "output_kw_max": 24.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016706", "000005", "0", "2013/Apr/08 09:51", "Baxi Heating UK", "Baxi", "Duo-tec 2 Combi", "28 GA", "", "2011", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "89.4", "80.8", "", "56.8", "", "2", "1", "", "104", "1", "2", "116", "3.5", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "92.0", "99.1", "", "", "", "", "97.8"]} +{"pcdb_id": 16707, "brand_name": "Baxi", "model_name": "Duo-tec 2 Combi", "model_qualifier": "33 GA", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 56.8, "output_kw_max": 28.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016707", "000005", "0", "2013/Apr/08 09:51", "Baxi Heating UK", "Baxi", "Duo-tec 2 Combi", "33 GA", "", "2011", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "28", "28", "", "", "89.4", "80.8", "", "56.8", "", "2", "1", "", "104", "1", "2", "132", "3.5", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "92.0", "99.2", "", "", "", "", "97.8"]} +{"pcdb_id": 16708, "brand_name": "Baxi", "model_name": "Duo-tec 2 Combi", "model_qualifier": "40 GA", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 56.8, "output_kw_max": 32.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016708", "000005", "0", "2013/Apr/08 09:52", "Baxi Heating UK", "Baxi", "Duo-tec 2 Combi", "40 GA", "", "2011", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "32", "32", "", "", "89.4", "80.8", "", "56.8", "", "2", "1", "", "104", "1", "2", "142", "3.5", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "92.0", "99.1", "", "", "", "", "97.8"]} +{"pcdb_id": 16709, "brand_name": "Baxi", "model_name": "Megaflo 2 System", "model_qualifier": "12 Compact GA", "winter_efficiency_pct": 89.5, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 58.8, "output_kw_max": 12.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016709", "000005", "0", "2012/Mar/27 10:12", "Baxi Heating UK", "Baxi", "Megaflo 2 System", "12 Compact GA", "", "2011", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "12", "12", "", "", "89.5", "80.5", "", "58.8", "", "2", "1", "", "102", "1", "2", "110", "3.5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "92.0", "99.3", "", "", "", "", "97.9"]} +{"pcdb_id": 16710, "brand_name": "Baxi", "model_name": "Megaflo 2 System", "model_qualifier": "15 Compact GA", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 80.4, "comparative_hot_water_efficiency_pct": 58.8, "output_kw_max": 15.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016710", "000005", "0", "2012/Mar/27 10:12", "Baxi Heating UK", "Baxi", "Megaflo 2 System", "15 Compact GA", "", "2011", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "15", "15", "", "", "89.4", "80.4", "", "58.8", "", "2", "1", "", "102", "1", "2", "108", "3.5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "92.0", "99.2", "", "", "", "", "97.8"]} +{"pcdb_id": 16711, "brand_name": "Baxi", "model_name": "Megaflo 2 System", "model_qualifier": "18 Compact GA", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 80.4, "comparative_hot_water_efficiency_pct": 58.8, "output_kw_max": 18.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016711", "000005", "0", "2012/Mar/27 10:12", "Baxi Heating UK", "Baxi", "Megaflo 2 System", "18 Compact GA", "", "2011", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "18", "18", "", "", "89.4", "80.4", "", "58.8", "", "2", "1", "", "102", "1", "2", "125", "3.5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "92.0", "99.2", "", "", "", "", "97.8"]} +{"pcdb_id": 16712, "brand_name": "Baxi", "model_name": "Megaflo 2 System", "model_qualifier": "24 Compact GA", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 80.4, "comparative_hot_water_efficiency_pct": 58.7, "output_kw_max": 24.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016712", "000005", "0", "2012/Mar/27 10:12", "Baxi Heating UK", "Baxi", "Megaflo 2 System", "24 Compact GA", "", "2011", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "24", "24", "", "", "89.4", "80.4", "", "58.7", "", "2", "1", "", "102", "1", "2", "104", "3.5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "92.0", "99.1", "", "", "", "", "97.8"]} +{"pcdb_id": 16713, "brand_name": "Baxi", "model_name": "Megaflo 2 System", "model_qualifier": "28 Compact GA", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 80.4, "comparative_hot_water_efficiency_pct": 58.7, "output_kw_max": 28.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016713", "000005", "0", "2012/Mar/27 10:12", "Baxi Heating UK", "Baxi", "Megaflo 2 System", "28 Compact GA", "", "2011", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "28", "28", "", "", "89.4", "80.4", "", "58.7", "", "2", "1", "", "102", "1", "2", "135", "3.5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "92.0", "99.1", "", "", "", "", "97.8"]} +{"pcdb_id": 16714, "brand_name": "Baxi", "model_name": "Megaflo 2 System", "model_qualifier": "32 Compact GA", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 80.4, "comparative_hot_water_efficiency_pct": 58.7, "output_kw_max": 32.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016714", "000005", "0", "2012/Mar/27 10:12", "Baxi Heating UK", "Baxi", "Megaflo 2 System", "32 Compact GA", "", "2011", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "32", "32", "", "", "89.4", "80.4", "", "58.7", "", "2", "1", "", "102", "1", "2", "132", "3.5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "92.0", "99.1", "", "", "", "", "97.8"]} +{"pcdb_id": 16715, "brand_name": "Sime", "model_name": "Estelle HE", "model_qualifier": "5", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 80.7, "comparative_hot_water_efficiency_pct": 59.0, "output_kw_max": 38.8, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016715", "000213", "0", "2015/Oct/08 11:02", "Fonderie Sime S.p.A.", "Sime", "Estelle HE", "5", "", "2010", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "38.8", "38.8", "", "", "88.5", "80.7", "", "59.0", "", "2", "", "", "201", "1", "1", "260", "0.1", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.9", "96.0", "", "", "", "", "95.1"]} +{"pcdb_id": 16716, "brand_name": "Sime", "model_name": "Estelle HE", "model_qualifier": "4", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 80.7, "comparative_hot_water_efficiency_pct": 59.0, "output_kw_max": 28.8, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016716", "000213", "0", "2015/Oct/08 11:02", "Fonderie Sime S.p.A.", "Sime", "Estelle HE", "4", "", "2010", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "28.8", "28.8", "", "", "88.5", "80.7", "", "59.0", "", "2", "", "", "201", "1", "1", "260", "0.1", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.0", "96.5", "", "", "", "", "95.3"]} +{"pcdb_id": 16717, "brand_name": "Sime", "model_name": "Estelle HE", "model_qualifier": "B4 INOX", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 81.1, "comparative_hot_water_efficiency_pct": 57.1, "output_kw_max": 28.8, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016717", "000213", "0", "2015/Oct/08 11:39", "Fonderie Sime S.p.A.", "Sime", "Estelle HE", "B4 INOX", "", "2010", "current", "4", "1", "1", "2", "0", "", "", "2", "3", "2", "28.8", "28.8", "", "", "88.5", "81.1", "", "57.1", "", "2", "", "", "202", "1", "1", "260", "0.1", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.0", "96.5", "", "", "", "", "95.3"]} +{"pcdb_id": 16720, "brand_name": "Saturn", "model_name": "NHC", "model_qualifier": "25B", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 80.9, "comparative_hot_water_efficiency_pct": 56.9, "output_kw_max": 24.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016720", "000268", "0", "2011/Nov/09 10:04", "KD Navien", "Saturn", "NHC", "25B", "", "2006", "current", "4", "1", "1", "2", "0", "", "", "2", "1", "2", "24", "24", "", "", "88.3", "80.9", "", "56.9", "", "2", "", "", "202", "1", "1", "143", "115", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "93.6", "94.4", "", "", "", "", "94.3"]} +{"pcdb_id": 16721, "brand_name": "Saturn", "model_name": "NHC", "model_qualifier": "41B", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 56.8, "output_kw_max": 38.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016721", "000268", "0", "2011/Nov/09 10:04", "KD Navien", "Saturn", "NHC", "41B", "", "2006", "current", "4", "1", "1", "2", "0", "", "", "2", "1", "2", "38", "38", "", "", "88.2", "80.8", "", "56.8", "", "2", "", "", "202", "1", "1", "199", "140", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "93.6", "94.1", "", "", "", "", "94.0"]} +{"pcdb_id": 16722, "brand_name": "Saturn", "model_name": "NHC", "model_qualifier": "30B", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 56.9, "output_kw_max": 30.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016722", "000268", "0", "2014/Nov/25 09:39", "KD Navien", "Saturn", "NHC", "30B", "", "2006", "current", "4", "1", "1", "2", "0", "", "", "2", "1", "2", "30", "30", "", "", "88.2", "80.8", "", "56.9", "", "2", "", "", "202", "1", "1", "150", "121", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "93.6", "94.3", "", "", "", "", "94.1"]} +{"pcdb_id": 16723, "brand_name": "Fondital", "model_name": "Antea KRB 24", "model_qualifier": "", "winter_efficiency_pct": 87.5, "summer_efficiency_pct": 78.5, "comparative_hot_water_efficiency_pct": 57.4, "output_kw_max": 22.9, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016723", "000250", "0", "2012/Mar/27 10:12", "Fondital", "Fondital", "Antea KRB 24", "", "", "2011", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "22.9", "22.9", "", "", "87.5", "78.5", "", "57.4", "", "2", "", "", "102", "1", "2", "131", "80", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.1", "96.0", "", "", "", "", "94.3"]} +{"pcdb_id": 16724, "brand_name": "Fondital", "model_name": "Antea KRB 24", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 22.9, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016724", "000250", "0", "2012/Mar/27 10:12", "Fondital", "Fondital", "Antea KRB 24", "", "", "2011", "current", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "22.9", "22.9", "", "", "88.5", "79.5", "", "58.1", "", "2", "1", "", "102", "1", "2", "131", "80", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.1", "98.1", "", "", "", "", "96.4"]} +{"pcdb_id": 16725, "brand_name": "Fondital", "model_name": "Antea KC 24", "model_qualifier": "", "winter_efficiency_pct": 87.5, "summer_efficiency_pct": 86.4, "comparative_hot_water_efficiency_pct": 74.3, "output_kw_max": 22.9, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.01, "loss_factor_f1_kwh_per_day": 0.89532, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016725", "000250", "0", "2011/Aug/25 09:32", "Fondital", "Fondital", "Antea KC 24", "", "", "2011", "current", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "22.9", "22.9", "", "", "87.5", "86.4", "", "74.3", "", "2", "", "", "104", "1", "2", "131", "80", "0", "", "", "", "0", "", "", "", "", "1", "7.09", "0.1", "0.01", "0.89532", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.1", "96.0", "", "", "", "", "94.3"]} +{"pcdb_id": 16726, "brand_name": "Fondital", "model_name": "Antea KC 24", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 56.2, "output_kw_max": 22.9, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016726", "000250", "0", "2013/Apr/08 09:55", "Fondital", "Fondital", "Antea KC 24", "", "", "2011", "current", "2", "2", "1", "2", "0", "", "", "2", "3", "2", "22.9", "22.9", "", "", "88.5", "79.9", "", "56.2", "", "2", "1", "", "104", "1", "2", "131", "80", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.1", "98.1", "", "", "", "", "96.4"]} +{"pcdb_id": 16727, "brand_name": "Fondital", "model_name": "Antea KR 24", "model_qualifier": "", "winter_efficiency_pct": 87.5, "summer_efficiency_pct": 78.5, "comparative_hot_water_efficiency_pct": 57.4, "output_kw_max": 22.9, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016727", "000250", "0", "2012/Mar/27 10:12", "Fondital", "Fondital", "Antea KR 24", "", "", "2011", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "22.9", "22.9", "", "", "87.5", "78.5", "", "57.4", "", "2", "", "", "102", "1", "2", "131", "80", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.1", "96.0", "", "", "", "", "94.3"]} +{"pcdb_id": 16728, "brand_name": "Fondital", "model_name": "Antea KR 24", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 22.9, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016728", "000250", "0", "2012/Mar/27 10:12", "Fondital", "Fondital", "Antea KR 24", "", "", "2011", "current", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "22.9", "22.9", "", "", "88.5", "79.5", "", "58.1", "", "2", "1", "", "102", "1", "2", "131", "80", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.1", "98.1", "", "", "", "", "96.4"]} +{"pcdb_id": 16729, "brand_name": "Baxi", "model_name": "Platinum 2 Combi", "model_qualifier": "28 GA", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 77.3, "output_kw_max": 24.0, "final_year_of_manufacture": 2012, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0044, "loss_factor_f1_kwh_per_day": 0.73349, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016729", "000005", "0", "2013/May/07 10:37", "Baxi Heating UK", "Baxi", "Platinum 2 Combi", "28 GA", "GL No 41-075-61", "2011", "2012", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "88.4", "87.3", "", "77.3", "", "2", "", "", "104", "1", "2", "135", "3.5", "0", "", "", "", "0", "", "", "", "", "1", "6.813", "0.118", "0.0044", "0.73349", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.0", "96.9", "", "", "", "", "95.6"]} +{"pcdb_id": 16730, "brand_name": "Baxi", "model_name": "Platinum 2 Combi", "model_qualifier": "33 GA", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 77.2, "output_kw_max": 28.0, "final_year_of_manufacture": 2012, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0045, "loss_factor_f1_kwh_per_day": 0.74098, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016730", "000005", "0", "2013/May/07 10:37", "Baxi Heating UK", "Baxi", "Platinum 2 Combi", "33 GA", "GC No 47-075-62", "2011", "2012", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28", "28", "", "", "88.4", "87.3", "", "77.2", "", "2", "", "", "104", "1", "2", "145", "3.5", "0", "", "", "", "0", "", "", "", "", "1", "6.821", "0.106", "0.0045", "0.74098", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.0", "97.0", "", "", "", "", "95.7"]} +{"pcdb_id": 16731, "brand_name": "Baxi", "model_name": "Platinum 2 Combi", "model_qualifier": "40 GA", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 77.8, "output_kw_max": 32.0, "final_year_of_manufacture": 2012, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0036, "loss_factor_f1_kwh_per_day": 0.69163, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016731", "000005", "0", "2013/May/07 10:38", "Baxi Heating UK", "Baxi", "Platinum 2 Combi", "40 GA", "GC No 47-075-63", "2011", "2012", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "32", "32", "", "", "88.4", "87.3", "", "77.8", "", "2", "", "", "104", "1", "2", "140", "3.5", "0", "", "", "", "0", "", "", "", "", "1", "6.765", "0.111", "0.0036", "0.69163", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.0", "96.9", "", "", "", "", "95.6"]} +{"pcdb_id": 16732, "brand_name": "Pro", "model_name": "Procombi Exclusive", "model_qualifier": "24", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 62.2, "output_kw_max": 24.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016732", "000247", "0", "2011/Nov/07 13:46", "Ideal Boilers", "Pro", "Procombi Exclusive", "24", "47-348-79", "2011", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "88.3", "79.7", "", "62.2", "", "2", "", "", "104", "1", "2", "146", "1", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "", "0035", "", "", "", "", "", "", "", "", "89.8", "96.9", "", "", "", "", "95.5"]} +{"pcdb_id": 16733, "brand_name": "Pro", "model_name": "Procombi Exclusive", "model_qualifier": "30", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 62.3, "output_kw_max": 24.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016733", "000247", "0", "2011/Nov/07 13:46", "Ideal Boilers", "Pro", "Procombi Exclusive", "30", "47-348-80", "2011", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "88.4", "79.8", "", "62.3", "", "2", "", "", "104", "1", "2", "152", "1", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "", "0035", "", "", "", "", "", "", "", "", "90.0", "96.9", "", "", "", "", "95.6"]} +{"pcdb_id": 16734, "brand_name": "Pro", "model_name": "Procombi Exclusive", "model_qualifier": "35", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 62.3, "output_kw_max": 24.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016734", "000247", "0", "2011/Nov/07 13:47", "Ideal Boilers", "Pro", "Procombi Exclusive", "35", "47-348-81", "2011", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "88.4", "79.8", "", "62.3", "", "2", "", "", "104", "1", "2", "177", "1", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "", "0035", "", "", "", "", "", "", "", "", "89.8", "96.9", "", "", "", "", "95.6"]} +{"pcdb_id": 16736, "brand_name": "i", "model_name": "35", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 62.3, "output_kw_max": 24.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016736", "000008", "0", "2013/Sep/12 14:49", "Ideal Boilers", "i", "35", "", "47-348-84", "2011", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "88.4", "79.8", "", "62.3", "", "2", "", "", "104", "1", "2", "177", "1", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "", "0035", "", "", "", "", "", "", "", "", "89.8", "96.9", "", "", "", "", "95.6"]} +{"pcdb_id": 16737, "brand_name": "i", "model_name": "30", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 62.3, "output_kw_max": 24.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016737", "000008", "0", "2013/Sep/12 14:49", "Ideal Boilers", "i", "30", "", "47-348-83", "2011", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "88.4", "79.8", "", "62.3", "", "2", "", "", "104", "1", "2", "152", "1", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "", "0035", "", "", "", "", "", "", "", "", "90.0", "96.9", "", "", "", "", "95.6"]} +{"pcdb_id": 16738, "brand_name": "i", "model_name": "24", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 62.2, "output_kw_max": 24.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016738", "000008", "0", "2013/Sep/12 14:49", "Ideal Boilers", "i", "24", "", "47-348-82", "2011", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "88.3", "79.7", "", "62.2", "", "2", "", "", "104", "1", "2", "146", "1", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "", "0035", "", "", "", "", "", "", "", "", "89.8", "96.9", "", "", "", "", "95.5"]} +{"pcdb_id": 16739, "brand_name": "Ideal", "model_name": "Independent +", "model_qualifier": "C24", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 69.3, "output_kw_max": 24.2, "final_year_of_manufacture": 2016, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.008, "loss_factor_f1_kwh_per_day": 1.46665, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016739", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "Independent +", "C24", "47-348-85", "2011", "2016", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "88.4", "87.3", "", "69.3", "", "2", "", "", "104", "1", "2", "146", "1", "0", "", "", "", "0", "", "", "", "", "1", "7.5959", "0.1755", "0.008", "1.46665", "", "", "", "", "", "1", "1", "", "0035", "", "", "", "", "", "", "", "", "89.8", "96.9", "", "", "", "", "95.6"]} +{"pcdb_id": 16740, "brand_name": "Ideal", "model_name": "Independent +", "model_qualifier": "C30", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 69.8, "output_kw_max": 24.2, "final_year_of_manufacture": 2016, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0099, "loss_factor_f1_kwh_per_day": 1.41408, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016740", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "Independent +", "C30", "47-348-86", "2011", "2016", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "88.4", "87.3", "", "69.8", "", "2", "", "", "104", "1", "2", "152", "1", "0", "", "", "", "0", "", "", "", "", "1", "7.548", "0.1749", "0.0099", "1.41408", "", "", "", "", "", "1", "1", "", "0035", "", "", "", "", "", "", "", "", "90.0", "96.9", "", "", "", "", "95.6"]} +{"pcdb_id": 16741, "brand_name": "Ideal", "model_name": "Independent +", "model_qualifier": "C35", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 71.0, "output_kw_max": 24.2, "final_year_of_manufacture": 2016, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0087, "loss_factor_f1_kwh_per_day": 1.2937, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016741", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "Independent +", "C35", "47-348-87", "2011", "2016", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "88.3", "87.3", "", "71.0", "", "2", "", "", "104", "1", "2", "177", "1", "0", "", "", "", "0", "", "", "", "", "1", "7.4216", "0.171", "0.0087", "1.2937", "", "", "", "", "", "1", "1", "", "0035", "", "", "", "", "", "", "", "", "89.8", "96.9", "", "", "", "", "95.5"]} +{"pcdb_id": 16742, "brand_name": "Ideal", "model_name": "Independent System", "model_qualifier": "15", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 15.0, "final_year_of_manufacture": 2016, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016742", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "Independent System", "15", "41-750-48", "2011", "2016", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "15", "15", "", "", "88.6", "79.6", "", "58.2", "", "2", "", "", "102", "1", "2", "126", "1", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "89.7", "97.7", "", "", "", "", "96.2"]} +{"pcdb_id": 16743, "brand_name": "Ideal", "model_name": "Independent System", "model_qualifier": "18", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 18.0, "final_year_of_manufacture": 2016, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016743", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "Independent System", "18", "47-750-49", "2011", "2016", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18", "18", "", "", "88.5", "79.5", "", "58.1", "", "2", "", "", "102", "1", "2", "131", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "89.6", "97.4", "", "", "", "", "95.9"]} +{"pcdb_id": 16744, "brand_name": "Ideal", "model_name": "Independent System", "model_qualifier": "24", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 24.2, "final_year_of_manufacture": 2016, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016744", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "Independent System", "24", "41-750-50", "2011", "2016", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "88.8", "79.8", "", "58.3", "", "2", "", "", "102", "1", "2", "146", "1", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "89.6", "98.0", "", "", "", "", "96.4"]} +{"pcdb_id": 16745, "brand_name": "Ideal", "model_name": "Independent System", "model_qualifier": "30", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 30.3, "final_year_of_manufacture": 2016, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016745", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "Independent System", "30", "41/750/51", "2011", "2016", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "30.3", "30.3", "", "", "88.9", "79.9", "", "58.3", "", "2", "", "", "102", "1", "2", "152", "1", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "89.8", "98.2", "", "", "", "", "96.6"]} +{"pcdb_id": 16746, "brand_name": "Vokera", "model_name": "Mynute", "model_qualifier": "35 HE", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 33.67, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016746", "000011", "0", "2012/Mar/27 10:12", "Vokera", "Vokera", "Mynute", "35 HE", "4109464", "2006", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "33.67", "33.67", "", "", "88.1", "79.1", "", "57.8", "", "2", "", "", "102", "1", "2", "165", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.7", "97.1", "", "", "", "", "95.3"]} +{"pcdb_id": 16747, "brand_name": "Sime", "model_name": "Murelle Equipe", "model_qualifier": "50BOX", "winter_efficiency_pct": 89.3, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 58.7, "output_kw_max": 46.7, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016747", "000213", "0", "2018/Jul/11 10:02", "Fonderie Sime S.p.A.", "Sime", "Murelle Equipe", "50BOX", "", "2011", "2018", "2", "2", "2", "1", "0", "", "", "2", "2", "2", "46.7", "46.7", "", "", "89.3", "80.3", "", "58.7", "", "2", "1", "", "102", "1", "2", "180", "4.4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.7", "99.9", "", "", "", "", "98.0"]} +{"pcdb_id": 16748, "brand_name": "Sime", "model_name": "Murelle Equipe", "model_qualifier": "50BOX", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 46.7, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016748", "000213", "0", "2015/Oct/08 12:07", "Fonderie Sime S.p.A.", "Sime", "Murelle Equipe", "50BOX", "", "2011", "current", "1", "2", "2", "1", "0", "", "", "2", "2", "2", "46.7", "46.7", "", "", "88.3", "79.3", "", "58.0", "", "2", "", "", "102", "1", "2", "180", "4.4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "97.8", "", "", "", "", "95.9"]} +{"pcdb_id": 16749, "brand_name": "Sime", "model_name": "Murelle HE", "model_qualifier": "50R", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 80.4, "comparative_hot_water_efficiency_pct": 58.7, "output_kw_max": 46.8, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016749", "000213", "0", "2018/Mar/07 10:12", "Fonderie Sime S.p.A.", "Sime", "Murelle HE", "50R", "", "2011", "2018", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "46.8", "46.8", "", "", "89.4", "80.4", "", "58.7", "", "2", "1", "", "102", "1", "2", "180", "4.4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.1", "99.9", "", "", "", "", "98.1"]} +{"pcdb_id": 16750, "brand_name": "Sime", "model_name": "Murelle HE", "model_qualifier": "50R", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 46.8, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016750", "000213", "0", "2018/Mar/07 10:11", "Fonderie Sime S.p.A.", "Sime", "Murelle HE", "50R", "", "2011", "2018", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "46.8", "46.8", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "180", "4.4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.1", "97.8", "", "", "", "", "95.9"]} +{"pcdb_id": 16751, "brand_name": "Sime", "model_name": "Murelle HE", "model_qualifier": "35R", "winter_efficiency_pct": 89.5, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 58.8, "output_kw_max": 33.8, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016751", "000213", "0", "2018/Mar/05 17:00", "Fonderie Sime S.p.A.", "Sime", "Murelle HE", "35R", "", "2011", "2018", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "33.8", "33.8", "", "", "89.5", "80.5", "", "58.8", "", "2", "1", "", "102", "1", "2", "105", "4.6", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.7", "100.3", "", "", "", "", "98.3"]} +{"pcdb_id": 16752, "brand_name": "Sime", "model_name": "Murelle HE", "model_qualifier": "35R", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 33.8, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016752", "000213", "0", "2018/Mar/05 16:59", "Fonderie Sime S.p.A.", "Sime", "Murelle HE", "35R", "", "2011", "2018", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "33.8", "33.8", "", "", "88.5", "79.5", "", "58.1", "", "2", "", "", "102", "1", "2", "105", "4.6", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "98.1", "", "", "", "", "96.2"]} +{"pcdb_id": 16753, "brand_name": "Sime", "model_name": "Murelle HM", "model_qualifier": "35T", "winter_efficiency_pct": 89.7, "summer_efficiency_pct": 80.7, "comparative_hot_water_efficiency_pct": 59.0, "output_kw_max": 34.1, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016753", "000213", "0", "2018/Mar/07 10:20", "Fonderie Sime S.p.A.", "Sime", "Murelle HM", "35T", "", "2011", "2018", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "34.1", "34.1", "", "", "89.7", "80.7", "", "59.0", "", "2", "1", "", "102", "1", "2", "105", "4.6", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "91.1", "100.3", "", "", "", "", "98.5"]} +{"pcdb_id": 16754, "brand_name": "Sime", "model_name": "Murelle HM", "model_qualifier": "35T", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 34.1, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016754", "000213", "0", "2018/Mar/07 10:19", "Fonderie Sime S.p.A.", "Sime", "Murelle HM", "35T", "", "2011", "2018", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "34.1", "34.1", "", "", "88.7", "79.7", "", "58.2", "", "2", "", "", "102", "1", "2", "105", "4.6", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.1", "98.1", "", "", "", "", "96.4"]} +{"pcdb_id": 16755, "brand_name": "Sime", "model_name": "Murelle HM", "model_qualifier": "25T", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 80.4, "comparative_hot_water_efficiency_pct": 58.7, "output_kw_max": 23.9, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016755", "000213", "0", "2018/Mar/07 10:16", "Fonderie Sime S.p.A.", "Sime", "Murelle HM", "25T", "", "2011", "2018", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "23.9", "23.9", "", "", "89.4", "80.4", "", "58.7", "", "2", "1", "", "102", "1", "2", "90", "3.4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "91.1", "99.6", "", "", "", "", "98.0"]} +{"pcdb_id": 16756, "brand_name": "Sime", "model_name": "Murelle HM", "model_qualifier": "25T", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 23.9, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016756", "000213", "0", "2018/Mar/07 10:15", "Fonderie Sime S.p.A.", "Sime", "Murelle HM", "25T", "", "2011", "2018", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "23.9", "23.9", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "90", "3.4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.1", "97.4", "", "", "", "", "95.8"]} +{"pcdb_id": 16757, "brand_name": "Sime", "model_name": "Murelle HM", "model_qualifier": "25", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 56.8, "output_kw_max": 23.9, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016757", "000213", "0", "2018/Mar/07 10:14", "Fonderie Sime S.p.A.", "Sime", "Murelle HM", "25", "", "2011", "2018", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "23.9", "23.9", "", "", "89.4", "80.8", "", "56.8", "", "2", "1", "", "104", "1", "2", "90", "3.4", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "91.1", "99.6", "", "", "", "", "98.0"]} +{"pcdb_id": 16758, "brand_name": "Sime", "model_name": "Murelle HM", "model_qualifier": "25", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 56.1, "output_kw_max": 23.9, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016758", "000213", "0", "2018/Mar/07 10:14", "Fonderie Sime S.p.A.", "Sime", "Murelle HM", "25", "", "2011", "2018", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "23.9", "23.9", "", "", "88.4", "79.8", "", "56.1", "", "2", "", "", "104", "1", "2", "90", "3.4", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.1", "97.4", "", "", "", "", "95.8"]} +{"pcdb_id": 16759, "brand_name": "Sime", "model_name": "Murelle HM", "model_qualifier": "35", "winter_efficiency_pct": 89.7, "summer_efficiency_pct": 81.1, "comparative_hot_water_efficiency_pct": 57.0, "output_kw_max": 34.1, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016759", "000213", "0", "2018/Mar/07 10:19", "Fonderie Sime S.p.A.", "Sime", "Murelle HM", "35", "", "2011", "2018", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "34.1", "34.1", "", "", "89.7", "81.1", "", "57.0", "", "2", "1", "", "104", "1", "2", "105", "4.6", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "91.1", "100.3", "", "", "", "", "98.5"]} +{"pcdb_id": 16760, "brand_name": "Sime", "model_name": "Murelle HM", "model_qualifier": "35", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 56.3, "output_kw_max": 34.1, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016760", "000213", "0", "2018/Mar/07 10:18", "Fonderie Sime S.p.A.", "Sime", "Murelle HM", "35", "", "2011", "2018", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "34.1", "34.1", "", "", "88.7", "80.1", "", "56.3", "", "2", "", "", "104", "1", "2", "105", "4.6", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.1", "98.1", "", "", "", "", "96.4"]} +{"pcdb_id": 16761, "brand_name": "Sime", "model_name": "Murelle HM", "model_qualifier": "30", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 56.5, "output_kw_max": 28.8, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016761", "000213", "0", "2018/Mar/07 10:17", "Fonderie Sime S.p.A.", "Sime", "Murelle HM", "30", "", "2011", "2018", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "28.8", "28.8", "", "", "88.9", "80.3", "", "56.5", "", "2", "1", "", "104", "1", "2", "90", "3.4", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.9", "98.7", "", "", "", "", "97.1"]} +{"pcdb_id": 16762, "brand_name": "Sime", "model_name": "Murelle HM", "model_qualifier": "30", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 55.8, "output_kw_max": 28.8, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016762", "000213", "0", "2018/Mar/07 10:16", "Fonderie Sime S.p.A.", "Sime", "Murelle HM", "30", "", "2011", "2018", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28.8", "28.8", "", "", "87.9", "79.3", "", "55.8", "", "2", "", "", "104", "1", "2", "90", "3.4", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "96.6", "", "", "", "", "94.9"]} +{"pcdb_id": 16763, "brand_name": "Alpha", "model_name": "InTec 30GS", "model_qualifier": "", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 80.6, "comparative_hot_water_efficiency_pct": 56.7, "output_kw_max": 18.3, "final_year_of_manufacture": null, "subsidiary_type": 1, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016763", "000001", "3", "2021/Nov/29 20:19", "Alpha Therm", "Alpha", "InTec 30GS", "", "", "2011", "current", "2", "2", "1", "2", "1", "313", "060040", "2", "2", "2", "18.3", "18.3", "", "", "89.2", "80.6", "", "56.7", "", "2", "1", "", "104", "1", "2", "120", "6", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "1005", "", "", "", "", "", "", "", "", "90.7", "99.1", "", "", "", "", "97.5"]} +{"pcdb_id": 16764, "brand_name": "Alpha", "model_name": "InTec 30GS", "model_qualifier": "", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 86.9, "comparative_hot_water_efficiency_pct": 81.0, "output_kw_max": 18.3, "final_year_of_manufacture": null, "subsidiary_type": 1, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0085, "loss_factor_f1_kwh_per_day": 0.37658, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016764", "000001", "3", "2021/Nov/29 20:19", "Alpha Therm", "Alpha", "InTec 30GS", "", "", "2011", "current", "1", "2", "1", "2", "1", "313", "060039", "2", "2", "2", "18.3", "18.3", "", "", "88.2", "86.9", "", "81.0", "", "2", "", "", "104", "1", "2", "120", "6", "0", "", "", "", "0", "", "", "", "", "1", "6.5", "0.147", "0.0085", "0.37658", "", "", "", "", "", "", "", "", "1005", "", "", "", "", "", "", "", "", "88.7", "96.9", "", "", "", "", "95.4"]} +{"pcdb_id": 16765, "brand_name": "Alpha", "model_name": "InTec 40GS", "model_qualifier": "", "winter_efficiency_pct": 89.3, "summer_efficiency_pct": 80.7, "comparative_hot_water_efficiency_pct": 56.8, "output_kw_max": 28.0, "final_year_of_manufacture": null, "subsidiary_type": 1, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016765", "000001", "3", "2021/Nov/29 20:19", "Alpha Therm", "Alpha", "InTec 40GS", "", "", "2011", "current", "2", "2", "1", "2", "1", "313", "060040", "2", "2", "2", "28", "28", "", "", "89.3", "80.7", "", "56.8", "", "2", "1", "", "104", "1", "2", "125", "6", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "1005", "", "", "", "", "", "", "", "", "91.4", "99.2", "", "", "", "", "97.7"]} +{"pcdb_id": 16766, "brand_name": "Alpha", "model_name": "InTec 40GS", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 87.1, "comparative_hot_water_efficiency_pct": 79.4, "output_kw_max": 28.0, "final_year_of_manufacture": null, "subsidiary_type": 1, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.007, "loss_factor_f1_kwh_per_day": 0.52692, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016766", "000001", "3", "2021/Nov/29 20:19", "Alpha Therm", "Alpha", "InTec 40GS", "", "", "2011", "current", "1", "2", "1", "2", "1", "313", "060039", "2", "2", "2", "28", "28", "", "", "88.3", "87.1", "", "79.4", "", "2", "", "", "104", "1", "2", "125", "6", "0", "", "", "", "0", "", "", "", "", "1", "6.631", "0.121", "0.007", "0.52692", "", "", "", "", "", "", "", "", "1005", "", "", "", "", "", "", "", "", "89.4", "97.0", "", "", "", "", "95.6"]} +{"pcdb_id": 16767, "brand_name": "Ideal", "model_name": "Evomax", "model_qualifier": "60P", "winter_efficiency_pct": 89.8, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 59.0, "output_kw_max": 60.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016767", "000008", "0", "2012/Mar/27 10:12", "Ideal Boilers", "Ideal", "Evomax", "60P", "GC No 41-750-42", "2011", "current", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "60", "60", "", "", "89.8", "80.8", "", "59.0", "", "2", "1", "", "102", "1", "2", "74", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "91.7", "100.1", "", "", "", "", "98.5"]} +{"pcdb_id": 16768, "brand_name": "Ideal", "model_name": "Evomax", "model_qualifier": "40P", "winter_efficiency_pct": 89.6, "summer_efficiency_pct": 80.6, "comparative_hot_water_efficiency_pct": 58.9, "output_kw_max": 40.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016768", "000008", "0", "2012/Mar/27 10:12", "Ideal Boilers", "Ideal", "Evomax", "40P", "GC No 41-750-41", "2011", "current", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "40", "40", "", "", "89.6", "80.6", "", "58.9", "", "1", "1", "", "102", "1", "2", "148", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "91.5", "99.9", "", "", "", "", "98.3"]} +{"pcdb_id": 16769, "brand_name": "Ideal", "model_name": "Evomax", "model_qualifier": "30P", "winter_efficiency_pct": 89.9, "summer_efficiency_pct": 80.9, "comparative_hot_water_efficiency_pct": 59.1, "output_kw_max": 30.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016769", "000008", "0", "2012/Mar/27 10:12", "Ideal Boilers", "Ideal", "Evomax", "30P", "GB No 41-750-40", "2011", "current", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "30", "30", "", "", "89.9", "80.9", "", "59.1", "", "2", "1", "", "102", "1", "2", "67", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "91.6", "100.6", "", "", "", "", "98.9"]} +{"pcdb_id": 16770, "brand_name": "Ideal", "model_name": "Evomax", "model_qualifier": "60", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 60.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016770", "000008", "0", "2012/Mar/27 10:12", "Ideal Boilers", "Ideal", "Evomax", "60", "GC No 41-750-35A", "2001", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "60", "60", "", "", "88.7", "79.7", "", "58.2", "", "2", "", "", "102", "1", "2", "74", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.7", "97.9", "", "", "", "", "96.4"]} +{"pcdb_id": 16771, "brand_name": "Ideal", "model_name": "Evomax", "model_qualifier": "40", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 40.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016771", "000008", "0", "2012/Mar/27 10:12", "Ideal Boilers", "Ideal", "Evomax", "40", "GC No 41-750-34A", "2011", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "40", "40", "", "", "88.6", "79.6", "", "58.2", "", "2", "", "", "102", "1", "2", "148", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.6", "97.8", "", "", "", "", "96.2"]} +{"pcdb_id": 16772, "brand_name": "Ideal", "model_name": "Evomax", "model_qualifier": "30", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 30.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016772", "000008", "0", "2012/Mar/27 10:12", "Ideal Boilers", "Ideal", "Evomax", "30", "GC No 41-750-33A", "2011", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "30", "30", "", "", "88.9", "79.9", "", "58.4", "", "2", "", "", "102", "1", "2", "67", "10", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.6", "98.4", "", "", "", "", "96.7"]} +{"pcdb_id": 16773, "brand_name": "Potterton", "model_name": "Gold FSB", "model_qualifier": "30 HE", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 30.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016773", "000005", "0", "2015/Aug/06 13:03", "Baxi Heating UK", "Potterton", "Gold FSB", "30 HE", "GC No 41-592-32", "2011", "2015", "1", "1", "1", "1", "0", "", "", "2", "2", "2", "30", "30", "", "", "88.1", "79.1", "", "57.8", "", "2", "", "", "102", "1", "2", "1", "80", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.4", "96.4", "", "", "", "", "95.1"]} +{"pcdb_id": 16774, "brand_name": "Ideal", "model_name": "LOGIC COMBI", "model_qualifier": "E24", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 69.3, "output_kw_max": 24.2, "final_year_of_manufacture": 2012, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.008, "loss_factor_f1_kwh_per_day": 1.46665, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016774", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "LOGIC COMBI", "E24", "47-348-88", "2011", "2012", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "88.4", "87.3", "", "69.3", "", "1", "", "", "104", "1", "2", "146", "1", "0", "", "", "", "0", "", "", "", "", "1", "7.5959", "0.1755", "0.008", "1.46665", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.8", "96.9", "", "", "", "", "95.6"]} +{"pcdb_id": 16775, "brand_name": "Ideal", "model_name": "LOGIC COMBI", "model_qualifier": "E35", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 71.0, "output_kw_max": 24.2, "final_year_of_manufacture": 2012, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0087, "loss_factor_f1_kwh_per_day": 1.2937, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016775", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "LOGIC COMBI", "E35", "47-348-90", "2011", "2012", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "88.3", "87.3", "", "71.0", "", "2", "", "", "104", "1", "2", "177", "1", "0", "", "", "", "0", "", "", "", "", "1", "7.4216", "0.171", "0.0087", "1.2937", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.8", "96.9", "", "", "", "", "95.5"]} +{"pcdb_id": 16776, "brand_name": "Ideal", "model_name": "LOGIC COMBI", "model_qualifier": "E30", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 69.8, "output_kw_max": 24.2, "final_year_of_manufacture": 2012, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0099, "loss_factor_f1_kwh_per_day": 1.41408, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016776", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "LOGIC COMBI", "E30", "47-348-89", "2011", "2012", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "88.4", "87.3", "", "69.8", "", "2", "", "", "104", "1", "2", "152", "1", "0", "", "", "", "0", "", "", "", "", "1", "7.548", "0.1749", "0.0099", "1.41408", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.0", "96.9", "", "", "", "", "95.6"]} +{"pcdb_id": 16777, "brand_name": "Potterton", "model_name": "British Gas Potterton Precision", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 30.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016777", "000005", "0", "2015/Aug/06 13:04", "Baxi Heating UK", "Potterton", "British Gas Potterton Precision", "", "GC 41-592-33", "2001", "2015", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "30", "30", "", "", "88.1", "79.1", "", "57.8", "", "2", "", "", "102", "1", "2", "80", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.4", "96.5", "", "", "", "", "95.1"]} +{"pcdb_id": 16778, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "36LXi", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 87.0, "comparative_hot_water_efficiency_pct": 78.1, "output_kw_max": 24.0, "final_year_of_manufacture": 2012, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0009, "loss_factor_f1_kwh_per_day": 0.65506, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016778", "000035", "0", "2012/Dec/11 10:30", "Worcester Bosch Group", "Worcester", "Greenstar", "36LXi", "47-406-30", "2011", "2012", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "89.2", "87.0", "", "78.1", "", "2", "", "", "104", "1", "2", "141", "1", "0", "", "", "", "0", "", "", "", "", "1", "6.74", "0.087", "0.0009", "0.65506", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.8", "99.6", "", "", "", "", "97.5"]} +{"pcdb_id": 16779, "brand_name": "Rotex", "model_name": "GSU 320-e", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 81.4, "comparative_hot_water_efficiency_pct": 43.9, "output_kw_max": 20.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016779", "000246", "0", "2024/Jan/31 10:17", "Rotex Heating Systems", "Rotex", "GSU 320-e", "", "", "2007", "current", "1", "1", "1", "2", "0", "", "", "2", "3", "2", "20", "20", "", "", "88.3", "81.4", "", "43.9", "", "2", "", "", "106", "1", "2", "53", "8", "2", "2", "1", "289", "0", "70", "2", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.2", "97.9", "", "", "", "", "95.9"]} +{"pcdb_id": 16780, "brand_name": "Rotex", "model_name": "GSU 320F-e", "model_qualifier": "", "winter_efficiency_pct": 89.3, "summer_efficiency_pct": 82.4, "comparative_hot_water_efficiency_pct": 44.5, "output_kw_max": 20.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016780", "000246", "0", "2024/Jan/31 10:17", "Rotex Heating Systems", "Rotex", "GSU 320F-e", "", "", "2007", "current", "2", "1", "1", "2", "0", "", "", "2", "3", "2", "20", "20", "", "", "89.3", "82.4", "", "44.5", "", "2", "1", "", "106", "1", "2", "53", "8", "2", "2", "1", "289", "0", "70", "2", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "0", "", "0005", "", "", "", "", "", "", "", "", "89.2", "100.1", "", "", "", "", "98.0"]} +{"pcdb_id": 16781, "brand_name": "Rotex", "model_name": "GSU 520 S-e", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 81.6, "comparative_hot_water_efficiency_pct": 36.6, "output_kw_max": 20.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016781", "000246", "0", "2024/Jan/31 10:17", "Rotex Heating Systems", "Rotex", "GSU 520 S-e", "", "", "2007", "current", "1", "1", "1", "2", "0", "", "", "2", "3", "2", "20", "20", "", "", "88.3", "81.6", "", "36.6", "", "2", "", "", "106", "1", "2", "53", "8", "2", "2", "", "500", "0", "70", "2", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "0", "", "0005", "", "", "", "", "", "", "", "", "87.2", "97.9", "", "", "", "", "95.9"]} +{"pcdb_id": 16782, "brand_name": "Rotex", "model_name": "GSU 520SF-e", "model_qualifier": "", "winter_efficiency_pct": 89.3, "summer_efficiency_pct": 82.6, "comparative_hot_water_efficiency_pct": 37.1, "output_kw_max": 20.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016782", "000246", "0", "2024/Jan/31 10:17", "Rotex Heating Systems", "Rotex", "GSU 520SF-e", "", "", "2007", "current", "2", "1", "1", "2", "0", "", "", "2", "3", "2", "20", "20", "", "", "89.3", "82.6", "", "37.1", "", "2", "1", "", "106", "1", "2", "53", "8", "2", "2", "1", "500", "0", "70", "2", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "0", "", "0005", "", "", "", "", "", "", "", "", "89.2", "100.1", "", "", "", "", "98.0"]} +{"pcdb_id": 16783, "brand_name": "Rotex", "model_name": "GSU 530S-e", "model_qualifier": "", "winter_efficiency_pct": 87.5, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 36.3, "output_kw_max": 30.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016783", "000246", "0", "2024/Jan/31 10:17", "Rotex Heating Systems", "Rotex", "GSU 530S-e", "", "", "2007", "current", "1", "1", "1", "2", "0", "", "", "2", "3", "2", "30", "30", "", "", "87.5", "80.8", "", "36.3", "", "2", "", "", "106", "1", "2", "64", "8", "2", "2", "1", "500", "0", "70", "2", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "0", "", "0005", "", "", "", "", "", "", "", "", "86.5", "96.2", "", "", "", "", "94.4"]} +{"pcdb_id": 16784, "brand_name": "Rotex", "model_name": "GSU 530SF-e", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 81.8, "comparative_hot_water_efficiency_pct": 36.7, "output_kw_max": 30.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016784", "000246", "0", "2024/Jan/31 10:17", "Rotex Heating Systems", "Rotex", "GSU 530SF-e", "", "", "2007", "current", "2", "1", "1", "2", "0", "", "", "2", "3", "2", "30", "30", "", "", "88.5", "81.8", "", "36.7", "", "2", "1", "", "106", "1", "2", "64", "8", "2", "2", "1", "500", "0", "70", "2", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "0", "", "0005", "", "", "", "", "", "", "", "", "88.4", "98.4", "", "", "", "", "96.5"]} +{"pcdb_id": 16785, "brand_name": "Rotex", "model_name": "GSU 535-e", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 81.4, "comparative_hot_water_efficiency_pct": 36.5, "output_kw_max": 35.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016785", "000246", "0", "2024/Jan/31 10:17", "Rotex Heating Systems", "Rotex", "GSU 535-e", "", "", "2007", "current", "1", "1", "1", "2", "0", "", "", "2", "3", "2", "35", "35", "", "", "88.1", "81.4", "", "36.5", "", "2", "", "", "106", "1", "2", "85", "8", "2", "2", "1", "500", "0", "70", "2", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "0", "", "0005", "", "", "", "", "", "", "", "", "86.7", "97.6", "", "", "", "", "95.5"]} +{"pcdb_id": 16786, "brand_name": "Rotex", "model_name": "GSU 535F-e", "model_qualifier": "", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 82.4, "comparative_hot_water_efficiency_pct": 37.0, "output_kw_max": 35.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016786", "000246", "0", "2024/Jan/31 10:17", "Rotex Heating Systems", "Rotex", "GSU 535F-e", "", "", "2007", "current", "2", "1", "1", "2", "0", "", "", "2", "3", "2", "35", "35", "", "", "89.1", "82.4", "", "37.0", "", "2", "1", "", "106", "1", "2", "85", "8", "2", "2", "1", "500", "0", "70", "2", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "0", "", "0005", "", "", "", "", "", "", "", "", "88.6", "99.7", "", "", "", "", "97.6"]} +{"pcdb_id": 16787, "brand_name": "Potterton", "model_name": "Scottish Gas Potterton Precision", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 30.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016787", "000005", "0", "2015/Aug/06 13:06", "Baxi Heating UK", "Potterton", "Scottish Gas Potterton Precision", "", "GC 41-592-33", "2001", "2015", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "30", "30", "", "", "88.1", "79.1", "", "57.8", "", "2", "", "", "102", "1", "2", "80", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.4", "96.5", "", "", "", "", "95.1"]} +{"pcdb_id": 16788, "brand_name": "Biasi", "model_name": "Activ A Plus", "model_qualifier": "16S", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 15.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016788", "000208", "0", "2012/May/15 08:29", "Biasi UK", "Biasi", "Activ A Plus", "16S", "", "2011", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "15.6", "15.6", "", "", "89.0", "80.0", "", "58.4", "", "2", "1", "", "102", "1", "2", "94", "8.6", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.0", "98.9", "", "", "", "", "97.2"]} +{"pcdb_id": 16789, "brand_name": "Biasi", "model_name": "Activ A Plus", "model_qualifier": "16S", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 15.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016789", "000208", "0", "2012/May/15 08:29", "Biasi UK", "Biasi", "Activ A Plus", "16S", "41-583-20", "2011", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "15.6", "15.6", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "94", "8.6", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "96.8", "", "", "", "", "95.1"]} +{"pcdb_id": 16790, "brand_name": "Biasi", "model_name": "Activ A Plus", "model_qualifier": "25S", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 19.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016790", "000208", "0", "2012/May/15 08:29", "Biasi UK", "Biasi", "Activ A Plus", "25S", "41-583-21", "2011", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "19.5", "19.5", "", "", "89.1", "80.1", "", "58.5", "", "2", "1", "", "102", "1", "2", "102", "8.6", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.7", "99.2", "", "", "", "", "97.4"]} +{"pcdb_id": 16791, "brand_name": "Biasi", "model_name": "Activ A Plus", "model_qualifier": "25S", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 19.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016791", "000208", "0", "2012/May/15 08:29", "Biasi UK", "Biasi", "Activ A Plus", "25S", "41-583-21", "2011", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "19.5", "19.5", "", "", "88.1", "79.1", "", "57.7", "", "2", "", "", "102", "1", "2", "102", "8.6", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "97.0", "", "", "", "", "95.3"]} +{"pcdb_id": 16792, "brand_name": "Biasi", "model_name": "Activ A Plus", "model_qualifier": "30C", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.4, "comparative_hot_water_efficiency_pct": 56.5, "output_kw_max": 24.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016792", "000208", "0", "2013/Apr/08 09:56", "Biasi UK", "Biasi", "Activ A Plus", "30C", "47/583-26", "2011", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24.4", "24.4", "", "", "89.0", "80.4", "", "56.5", "", "2", "1", "", "104", "1", "2", "130", "8.6", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.3", "98.8", "", "", "", "", "97.2"]} +{"pcdb_id": 16793, "brand_name": "Biasi", "model_name": "Activ A Plus", "model_qualifier": "30C", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 86.8, "comparative_hot_water_efficiency_pct": 74.1, "output_kw_max": 24.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.002, "loss_factor_f1_kwh_per_day": 0.98571, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016793", "000208", "0", "2012/May/15 08:30", "Biasi UK", "Biasi", "Activ A Plus", "30C", "47-583-26", "2011", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.4", "24.4", "", "", "88.0", "86.8", "", "74.1", "", "2", "", "", "104", "1", "2", "130", "8.6", "0", "", "", "", "0", "", "", "", "", "1", "7.104", "0.163", "0.002", "0.98571", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "96.7", "", "", "", "", "95.1"]} +{"pcdb_id": 16794, "brand_name": "Biasi", "model_name": "Activ A Plus", "model_qualifier": "35C", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.4, "comparative_hot_water_efficiency_pct": 56.6, "output_kw_max": 29.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016794", "000208", "0", "2013/Apr/08 10:02", "Biasi (UK)", "Biasi", "Activ A Plus", "35C", "47-583-27", "2011", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "29.5", "29.5", "", "", "89.0", "80.4", "", "56.6", "", "2", "1", "", "104", "1", "2", "135", "8.6", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.4", "98.8", "", "", "", "", "97.2"]} +{"pcdb_id": 16795, "brand_name": "Biasi", "model_name": "Activ A Plus", "model_qualifier": "35C", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 86.8, "comparative_hot_water_efficiency_pct": 74.0, "output_kw_max": 29.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.002, "loss_factor_f1_kwh_per_day": 1.00577, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016795", "000208", "0", "2011/Oct/11 14:34", "Biasi (UK)", "Biasi", "Activ A Plus", "35C", "47-583-27", "2011", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "29.5", "29.5", "", "", "88.0", "86.8", "", "74.0", "", "2", "", "", "104", "1", "2", "135", "8.6", "0", "", "", "", "0", "", "", "", "", "1", "7.12", "0.152", "0.002", "1.00577", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.5", "96.7", "", "", "", "", "95.1"]} +{"pcdb_id": 16796, "brand_name": "Potterton", "model_name": "Apollo", "model_qualifier": "30", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 55.9, "output_kw_max": 28.6, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016796", "000005", "0", "2015/Aug/06 13:07", "Baxi Heating UK", "Potterton", "Apollo", "30", "GC No. 47-393-37", "2011", "2015", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28.6", "28.6", "", "", "88.1", "79.5", "", "55.9", "", "2", "", "", "104", "1", "2", "150", "3.5", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "88.0", "97.0", "", "", "", "", "95.3"]} +{"pcdb_id": 16797, "brand_name": "Potterton", "model_name": "Apollo", "model_qualifier": "25", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 56.1, "output_kw_max": 25.9, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016797", "000005", "0", "2015/Aug/06 13:07", "Baxi Heating UK", "Potterton", "Apollo", "25", "GC No 47-393-38", "2011", "2015", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "25.9", "25.9", "", "", "88.4", "79.8", "", "56.1", "", "2", "", "", "104", "1", "2", "150", "3.5", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "89.7", "97.0", "", "", "", "", "95.7"]} +{"pcdb_id": 16798, "brand_name": "Firebird", "model_name": "Enviromax Heatpac", "model_qualifier": "C12/18 kW", "winter_efficiency_pct": 89.5, "summer_efficiency_pct": 81.7, "comparative_hot_water_efficiency_pct": 59.7, "output_kw_max": 18.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016798", "000047", "0", "2012/Mar/27 10:12", "Firebird Boilers", "Firebird", "Enviromax Heatpac", "C12/18 kW", "", "2011", "current", "4", "1", "2", "1", "0", "", "", "2", "1", "1", "12", "18", "", "", "89.5", "81.7", "", "59.7", "", "2", "", "", "201", "1", "1", "38", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "92.7", "97.8", "", "", "", "", "96.8"]} +{"pcdb_id": 16799, "brand_name": "Firebird", "model_name": "Enviromax Popular", "model_qualifier": "C12/18KW", "winter_efficiency_pct": 89.5, "summer_efficiency_pct": 81.7, "comparative_hot_water_efficiency_pct": 59.7, "output_kw_max": 18.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016799", "000047", "0", "2012/Mar/27 10:12", "Firebird Boilers", "Firebird", "Enviromax Popular", "C12/18KW", "", "2011", "current", "4", "1", "1", "1", "0", "", "", "2", "2", "1", "12", "18", "", "", "89.5", "81.7", "", "59.7", "", "2", "", "", "201", "1", "1", "38", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "92.7", "97.8", "", "", "", "", "96.8"]} +{"pcdb_id": 16801, "brand_name": "ATAG", "model_name": "XL70", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 60.1, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016801", "000227", "0", "2013/Oct/23 12:58", "ATAG Verwarming Nederland BV", "ATAG", "XL70", "", "", "2011", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "60.1", "60.1", "", "", "88.8", "79.8", "", "58.3", "", "2", "", "", "102", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.7", "98.9", "", "", "", "", "96.8"]} +{"pcdb_id": 16804, "brand_name": "Vokera", "model_name": "Verve", "model_qualifier": "", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 45.78, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016804", "000011", "0", "2012/Mar/27 10:12", "Vokera", "Vokera", "Verve", "", "4109475", "2001", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "45.78", "45.78", "", "", "88.2", "79.2", "", "57.8", "", "2", "", "", "102", "1", "2", "164", "4.5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "87.8", "97.3", "", "", "", "", "95.5"]} +{"pcdb_id": 16805, "brand_name": "Biasi", "model_name": "ActivA Plus", "model_qualifier": "25C", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 86.6, "comparative_hot_water_efficiency_pct": 74.1, "output_kw_max": 19.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0, "loss_factor_f1_kwh_per_day": 0.98922, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016805", "000208", "0", "2012/Feb/08 08:22", "Biasi", "Biasi", "ActivA Plus", "25C", "47-583-28", "2012", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "19.5", "19.5", "", "", "88.1", "86.6", "", "74.1", "", "2", "", "", "104", "1", "2", "102", "8.6", "0", "", "", "", "0", "", "", "", "", "1", "7.11", "0.15", "0.0", "0.98922", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "97.0", "", "", "", "", "95.3"]} +{"pcdb_id": 16806, "brand_name": "Biasi", "model_name": "ActivA Plus", "model_qualifier": "25C", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 56.6, "output_kw_max": 19.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016806", "000208", "0", "2013/Apr/08 10:02", "Biasi UK", "Biasi", "ActivA Plus", "25C", "", "2012", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "19.5", "19.5", "", "", "89.1", "80.5", "", "56.6", "", "2", "1", "", "104", "1", "2", "102", "8.6", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.7", "99.2", "", "", "", "", "97.4"]} +{"pcdb_id": 16807, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "30 LXi System", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 30.0, "final_year_of_manufacture": 2012, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016807", "000035", "0", "2020/Sep/08 10:25", "Worcester Bosch Group", "Worcester", "Greenstar", "30 LXi System", "41-406-11", "2012", "2012", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "30", "30", "", "", "88.3", "79.3", "", "57.9", "", "2", "", "", "102", "1", "2", "116", "1", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.2", "97.4", "", "", "", "", "95.7"]} +{"pcdb_id": 16808, "brand_name": "Pro", "model_name": "Procombi CT", "model_qualifier": "25", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 56.1, "output_kw_max": 19.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016808", "000011", "0", "2012/Feb/02 15:21", "Vokera", "Pro", "Procombi CT", "25", "47 364 04", "2010", "current", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "19.5", "19.5", "", "", "88.4", "79.8", "", "56.1", "", "2", "", "", "104", "1", "2", "125", "4.5", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "97.8", "", "", "", "", "95.9"]} +{"pcdb_id": 16809, "brand_name": "Pro", "model_name": "Procombi CT", "model_qualifier": "29", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 56.0, "output_kw_max": 24.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016809", "000011", "0", "2012/Feb/02 15:21", "Vokera", "Pro", "Procombi CT", "29", "47 364 05", "2010", "current", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "24.4", "24.4", "", "", "88.3", "79.7", "", "56.0", "", "2", "", "", "104", "1", "2", "128", "4.5", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "97.6", "", "", "", "", "95.7"]} +{"pcdb_id": 16810, "brand_name": "Glow-worm", "model_name": "Betacom2 28", "model_qualifier": "", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 86.5, "comparative_hot_water_efficiency_pct": 73.5, "output_kw_max": 23.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0011, "loss_factor_f1_kwh_per_day": 1.03013, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016810", "000207", "0", "2013/Jan/30 14:32", "Vaillant Industrial UK", "Glow-worm", "Betacom2 28", "", "GC No 47-019-17", "2012", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "23.3", "23.3", "", "", "87.9", "86.5", "", "73.5", "", "2", "", "", "104", "1", "2", "68", "6", "0", "", "", "", "0", "", "", "", "", "1", "7.169", "0.101", "0.0011", "1.03013", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.4", "96.7", "", "", "", "", "94.9"]} +{"pcdb_id": 16811, "brand_name": "Glow-worm", "model_name": "Betacom2 28", "model_qualifier": "", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 56.4, "output_kw_max": 23.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016811", "000207", "0", "2013/Jan/30 14:31", "Vaillant Industrial UK", "Glow-worm", "Betacom2 28", "", "", "2012", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "23.3", "23.3", "", "", "88.9", "80.3", "", "56.4", "", "2", "1", "", "104", "1", "2", "68", "6", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.3", "98.8", "", "", "", "", "97.0"]} +{"pcdb_id": 16812, "brand_name": "Glow-worm", "model_name": "Easicom 28", "model_qualifier": "", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 86.5, "comparative_hot_water_efficiency_pct": 73.5, "output_kw_max": 23.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0011, "loss_factor_f1_kwh_per_day": 1.03013, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016812", "000207", "0", "2013/Jan/30 14:46", "Vaillant Industrial UK", "Glow-worm", "Easicom 28", "", "GC No 47-019-19", "2012", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "23.3", "23.3", "", "", "87.9", "86.5", "", "73.5", "", "2", "", "", "104", "1", "2", "68", "6", "0", "", "", "", "0", "", "", "", "", "1", "7.169", "0.101", "0.0011", "1.03013", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.4", "96.7", "", "", "", "", "94.9"]} +{"pcdb_id": 16813, "brand_name": "Glow-worm", "model_name": "Easicom 28", "model_qualifier": "", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 56.4, "output_kw_max": 23.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016813", "000207", "0", "2013/Jan/30 14:46", "Vaillant Industrial UK", "Glow-worm", "Easicom 28", "", "", "2012", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "23.3", "23.3", "", "", "88.9", "80.3", "", "56.4", "", "2", "1", "", "104", "1", "2", "68", "6", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.3", "98.8", "", "", "", "", "97.0"]} +{"pcdb_id": 16814, "brand_name": "Glow-worm", "model_name": "Betacom2 24", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 86.6, "comparative_hot_water_efficiency_pct": 73.5, "output_kw_max": 18.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0019, "loss_factor_f1_kwh_per_day": 1.03651, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016814", "000207", "0", "2013/Jan/30 14:30", "Vaillant Industrial UK", "Glow-worm", "Betacom2 24", "", "GC No 47-019-16", "2012", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "18", "18", "", "", "88.4", "86.6", "", "73.5", "", "2", "", "", "104", "1", "2", "68", "6", "0", "", "", "", "0", "", "", "", "", "1", "7.168", "0.101", "0.0019", "1.03651", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "97.8", "", "", "", "", "95.9"]} +{"pcdb_id": 16815, "brand_name": "Glow-worm", "model_name": "Betacom2 24", "model_qualifier": "", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 56.8, "output_kw_max": 18.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016815", "000207", "0", "2013/Jan/30 14:30", "Vaillant Industrial UK", "Glow-worm", "Betacom2 24", "", "", "2012", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "18", "18", "", "", "89.4", "80.8", "", "56.8", "", "2", "1", "", "104", "1", "2", "68", "6", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.8", "99.9", "", "", "", "", "98.0"]} +{"pcdb_id": 16816, "brand_name": "Glow-worm", "model_name": "Easicom 24", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 86.6, "comparative_hot_water_efficiency_pct": 73.5, "output_kw_max": 18.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0019, "loss_factor_f1_kwh_per_day": 1.03651, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016816", "000207", "0", "2013/Jan/30 14:45", "Vaillant Industrial UK", "Glow-worm", "Easicom 24", "", "GC No 47-019-18", "2012", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "18", "18", "", "", "88.4", "86.6", "", "73.5", "", "2", "", "", "104", "1", "2", "68", "6", "0", "", "", "", "0", "", "", "", "", "1", "7.168", "0.101", "0.0019", "1.03651", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "97.8", "", "", "", "", "95.9"]} +{"pcdb_id": 16817, "brand_name": "Glow-worm", "model_name": "Easicom 24", "model_qualifier": "", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 56.8, "output_kw_max": 18.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016817", "000207", "0", "2013/Jan/30 14:45", "Vaillant Industrial UK", "Glow-worm", "Easicom 24", "", "", "2012", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "18", "18", "", "", "89.4", "80.8", "", "56.8", "", "2", "1", "", "104", "1", "2", "68", "6", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.8", "99.9", "", "", "", "", "98.0"]} +{"pcdb_id": 16818, "brand_name": "Sime", "model_name": "Murelle HE", "model_qualifier": "35 R M", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 33.8, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016818", "000213", "0", "2018/Mar/05 16:58", "Fonderie Sime S.p.A.", "Sime", "Murelle HE", "35 R M", "", "2011", "2018", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "33.8", "33.8", "", "", "88.5", "79.5", "", "58.1", "", "2", "", "", "102", "1", "2", "105", "4.6", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "98.1", "", "", "", "", "96.2"]} +{"pcdb_id": 16819, "brand_name": "Sime", "model_name": "Murelle HE", "model_qualifier": "35R M", "winter_efficiency_pct": 89.5, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 58.8, "output_kw_max": 33.8, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016819", "000213", "0", "2018/Mar/07 09:47", "Fonderie Sime S.p.A.", "Sime", "Murelle HE", "35R M", "", "2011", "2018", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "33.8", "33.8", "", "", "89.5", "80.5", "", "58.8", "", "2", "1", "", "102", "1", "2", "105", "4.6", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.7", "100.3", "", "", "", "", "98.3"]} +{"pcdb_id": 16820, "brand_name": "Sime", "model_name": "Murelle HE 50R M", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 46.8, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016820", "000213", "0", "2018/Jul/11 10:04", "Fonderie Sime S.p.A.", "Sime", "Murelle HE 50R M", "", "", "2011", "2018", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "46.8", "46.8", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "130", "4.4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.1", "97.8", "", "", "", "", "95.9"]} +{"pcdb_id": 16821, "brand_name": "Sime", "model_name": "Murelle HE", "model_qualifier": "50R M", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 80.4, "comparative_hot_water_efficiency_pct": 58.7, "output_kw_max": 46.8, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016821", "000213", "0", "2018/Mar/07 10:13", "Fonderie Sime S.p.A.", "Sime", "Murelle HE", "50R M", "", "2011", "2018", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "46.8", "46.8", "", "", "89.4", "80.4", "", "58.7", "", "2", "1", "", "102", "1", "2", "130", "4.4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.1", "99.9", "", "", "", "", "98.1"]} +{"pcdb_id": 16822, "brand_name": "Ideal", "model_name": "LOGIC COMBI", "model_qualifier": "EC35", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 74.2, "output_kw_max": 24.2, "final_year_of_manufacture": 2013, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0089, "loss_factor_f1_kwh_per_day": 0.97663, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016822", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "LOGIC COMBI", "EC35", "47-348-96", "2012", "2013", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "88.3", "87.3", "", "74.2", "", "2", "", "", "104", "1", "2", "177", "1", "0", "", "", "", "0", "", "", "", "", "1", "7.0952", "0.1707", "0.0089", "0.97663", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.8", "96.9", "", "", "", "", "95.5"]} +{"pcdb_id": 16823, "brand_name": "Ideal", "model_name": "LOGIC COMBI", "model_qualifier": "EC30", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 73.2, "output_kw_max": 24.2, "final_year_of_manufacture": 2013, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0183, "loss_factor_f1_kwh_per_day": 1.0224, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016823", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "LOGIC COMBI", "EC30", "47-348-95", "2012", "2013", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "88.4", "87.3", "", "73.2", "", "2", "", "", "104", "1", "2", "152", "1", "0", "", "", "", "0", "", "", "", "", "1", "7.1946", "0.1567", "0.0183", "1.0224", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.0", "96.9", "", "", "", "", "95.6"]} +{"pcdb_id": 16824, "brand_name": "Ideal", "model_name": "LOGIC COMBI", "model_qualifier": "EC24", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 72.6, "output_kw_max": 24.2, "final_year_of_manufacture": 2013, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0157, "loss_factor_f1_kwh_per_day": 1.09285, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016824", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "LOGIC COMBI", "EC24", "47-348-94", "2012", "2013", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "88.4", "87.3", "", "72.6", "", "2", "", "", "104", "1", "2", "146", "1", "0", "", "", "", "0", "", "", "", "", "1", "7.2565", "0.1564", "0.0157", "1.09285", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.8", "96.9", "", "", "", "", "95.6"]} +{"pcdb_id": 16825, "brand_name": "The White Boiler Company", "model_name": "WH100 (T)", "model_qualifier": "", "winter_efficiency_pct": 89.3, "summer_efficiency_pct": 80.7, "comparative_hot_water_efficiency_pct": 56.8, "output_kw_max": 24.1, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016825", "000270", "0", "2013/Apr/08 10:02", "The White Boiler Company", "The White Boiler Company", "WH100 (T)", "", "", "2011", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24.1", "24.1", "", "", "89.3", "80.7", "", "56.8", "", "2", "1", "", "104", "1", "2", "160", "3", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.4", "99.6", "", "", "", "", "97.8"]} +{"pcdb_id": 16826, "brand_name": "The White Boiler Company", "model_name": "WH100 (T)", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 86.8, "comparative_hot_water_efficiency_pct": 67.3, "output_kw_max": 24.1, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0052, "loss_factor_f1_kwh_per_day": 1.66676, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016826", "000270", "0", "2012/Oct/26 10:48", "The White Boiler Company", "The White Boiler Company", "WH100 (T)", "", "", "2011", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.1", "24.1", "", "", "88.3", "86.8", "", "67.3", "", "2", "", "", "104", "1", "2", "160", "3", "0", "", "", "", "0", "", "", "", "", "1", "7.8249", "0.127", "0.0052", "1.66676", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.5", "97.4", "", "", "", "", "95.7"]} +{"pcdb_id": 16827, "brand_name": "The White Boiler Company", "model_name": "WH130 (T)", "model_qualifier": "", "winter_efficiency_pct": 89.3, "summer_efficiency_pct": 80.7, "comparative_hot_water_efficiency_pct": 56.8, "output_kw_max": 29.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016827", "000270", "0", "2013/Apr/08 10:03", "The White Boiler Company", "The White Boiler Company", "WH130 (T)", "", "", "2011", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "29", "29", "", "", "89.3", "80.7", "", "56.8", "", "2", "1", "", "104", "1", "2", "160", "3", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.3", "99.7", "", "", "", "", "97.9"]} +{"pcdb_id": 16828, "brand_name": "The White Boiler Company", "model_name": "WH130 (T)", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 86.8, "comparative_hot_water_efficiency_pct": 67.0, "output_kw_max": 29.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0049, "loss_factor_f1_kwh_per_day": 1.6922, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016828", "000270", "0", "2012/Oct/26 10:48", "The White Boiler Company", "The White Boiler Company", "WH130 (T)", "", "", "2011", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "29", "29", "", "", "88.3", "86.8", "", "67.0", "", "2", "", "", "104", "1", "2", "160", "3", "0", "", "", "", "0", "", "", "", "", "1", "7.8551", "0.1118", "0.0049", "1.6922", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "97.5", "", "", "", "", "95.7"]} +{"pcdb_id": 16829, "brand_name": "The White Boiler Company", "model_name": "WH Regular 6-24 (T)", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 24.1, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016829", "000270", "0", "2012/Apr/27 14:47", "The White Boiler Company", "The White Boiler Company", "WH Regular 6-24 (T)", "", "", "2011", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24.1", "24.1", "", "", "88.3", "79.3", "", "57.9", "", "2", "", "", "102", "1", "2", "160", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.5", "97.4", "", "", "", "", "95.7"]} +{"pcdb_id": 16830, "brand_name": "The White Boiler Company", "model_name": "WH Regular 9-32 (T)", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 29.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016830", "000270", "0", "2012/Apr/27 14:46", "The White Boiler Company", "The White Boiler Company", "WH Regular 9-32 (T)", "", "", "2011", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "29", "29", "", "", "88.3", "79.3", "", "57.9", "", "2", "", "", "102", "1", "2", "160", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "97.5", "", "", "", "", "95.7"]} +{"pcdb_id": 16831, "brand_name": "The White Boiler Company", "model_name": "WH System 6-24 (T)", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 24.1, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016831", "000270", "0", "2012/Apr/27 14:46", "The White Boiler Company", "The White Boiler Company", "WH System 6-24 (T)", "", "", "2011", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24.1", "24.1", "", "", "88.3", "79.3", "", "57.9", "", "2", "", "", "102", "1", "2", "160", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.5", "97.4", "", "", "", "", "95.7"]} +{"pcdb_id": 16832, "brand_name": "The White Boiler Company", "model_name": "WH System 9-32 (T)", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 29.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016832", "000270", "0", "2012/Apr/27 14:46", "The White Boiler Company", "The White Boiler Company", "WH System 9-32 (T)", "", "", "2011", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "29.0", "29.0", "", "", "88.3", "79.3", "", "57.9", "", "2", "", "", "102", "1", "2", "160", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "97.5", "", "", "", "", "95.7"]} +{"pcdb_id": 16833, "brand_name": "Vaillant", "model_name": "ecoTEC plus 637", "model_qualifier": "VU GB 376/5-5", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 37.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016833", "000031", "0", "2012/May/01 13:29", "Vaillant", "Vaillant", "ecoTEC plus 637", "VU GB 376/5-5", "GC 41-044-65", "2012", "2015", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "37", "37", "", "", "88.5", "79.5", "", "58.1", "", "2", "", "", "102", "1", "2", "130", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0045", "", "", "", "", "", "", "", "", "88.8", "97.8", "", "", "", "", "96.1"]} +{"pcdb_id": 16834, "brand_name": "Vaillant", "model_name": "ecoTEC plus 630", "model_qualifier": "VU GB 306/5-5", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 30.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016834", "000031", "0", "2012/May/30 09:07", "Vaillant", "Vaillant", "ecoTEC plus 630", "VU GB 306/5-5", "GC 41-044-64", "2012", "2015", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "30", "30", "", "", "88.7", "79.7", "", "58.2", "", "2", "", "", "102", "1", "2", "110", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0045", "", "", "", "", "", "", "", "", "88.7", "98.2", "", "", "", "", "96.4"]} +{"pcdb_id": 16835, "brand_name": "Vaillant", "model_name": "ecoTEC plus 624", "model_qualifier": "VU GB 246/5-5", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 24.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016835", "000031", "0", "2012/May/30 09:07", "Vaillant", "Vaillant", "ecoTEC plus 624", "VU GB 246/5-5", "GC 41-044-63", "2012", "2015", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24", "24", "", "", "88.7", "79.7", "", "58.2", "", "2", "", "", "102", "1", "2", "100", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0045", "", "", "", "", "", "", "", "", "89.0", "98.2", "", "", "", "", "96.5"]} +{"pcdb_id": 16836, "brand_name": "Vaillant", "model_name": "ecoTEC plus 618", "model_qualifier": "VU GB 186/5-5", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 18.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016836", "000031", "0", "2012/Apr/27 14:33", "Vaillant", "Vaillant", "ecoTEC plus 618", "VU GB 186/5-5", "GC 41-044-62", "2012", "2015", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18", "18", "", "", "88.6", "79.6", "", "58.2", "", "2", "", "", "102", "1", "2", "100", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0045", "", "", "", "", "", "", "", "", "89.5", "97.8", "", "", "", "", "96.2"]} +{"pcdb_id": 16837, "brand_name": "Vaillant", "model_name": "ecoTEC plus 615", "model_qualifier": "VU GB 156/5-5", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 15.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016837", "000031", "0", "2012/Apr/27 14:32", "Vaillant", "Vaillant", "ecoTEC plus 615", "VU GB 156/5-5", "GC 41-044-61", "2012", "2015", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "15", "15", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "95", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0045", "", "", "", "", "", "", "", "", "89.4", "97.3", "", "", "", "", "95.8"]} +{"pcdb_id": 16838, "brand_name": "Vaillant", "model_name": "ecoTEC plus 612", "model_qualifier": "VU GB 126/5-5", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 12.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016838", "000031", "0", "2012/Apr/27 14:32", "Vaillant", "Vaillant", "ecoTEC plus 612", "VU GB 126/5-5", "GC 41-044-60", "2012", "2015", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "12", "12", "", "", "88.3", "79.3", "", "57.9", "", "2", "", "", "102", "1", "2", "90", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0045", "", "", "", "", "", "", "", "", "88.7", "97.3", "", "", "", "", "95.7"]} +{"pcdb_id": 16839, "brand_name": "Vaillant", "model_name": "ecoTEC pro 28", "model_qualifier": "VUW GB 286/5-3", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 87.0, "comparative_hot_water_efficiency_pct": 75.1, "output_kw_max": 24.4, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0025, "loss_factor_f1_kwh_per_day": 0.91251, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016839", "000031", "0", "2019/Mar/04 10:28", "Vaillant", "Vaillant", "ecoTEC pro 28", "VUW GB 286/5-3", "GC 47-044-45", "2005", "2015", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.4", "24.4", "", "", "88.7", "87.0", "", "75.1", "", "2", "", "", "104", "1", "2", "105", "2", "0", "", "", "", "0", "", "", "", "", "1", "7.012", "0.133", "0.0025", "0.91251", "", "", "", "", "", "1", "1", "", "0045", "", "", "", "", "", "", "", "", "89.0", "98.0", "", "", "", "", "96.3"]} +{"pcdb_id": 16840, "brand_name": "Vaillant", "model_name": "ecoTEC pro 24", "model_qualifier": "VUW GB 246/5-3", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 87.0, "comparative_hot_water_efficiency_pct": 76.3, "output_kw_max": 18.9, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.003, "loss_factor_f1_kwh_per_day": 0.80529, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016840", "000031", "0", "2019/Mar/04 10:26", "Vaillant", "Vaillant", "ecoTEC pro 24", "VUW GB 246/5-3", "GC 47-044-44", "2005", "2015", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "18.9", "18.9", "", "", "88.5", "87.0", "", "76.3", "", "2", "", "", "104", "1", "2", "105", "2", "0", "", "", "", "0", "", "", "", "", "1", "6.904", "0.129", "0.003", "0.80529", "", "", "", "", "", "1", "1", "", "0045", "", "", "", "", "", "", "", "", "89.0", "97.8", "", "", "", "", "96.1"]} +{"pcdb_id": 16841, "brand_name": "Vaillant", "model_name": "ecoTEC plus 824", "model_qualifier": "VUW GB 246/5-5", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 87.0, "comparative_hot_water_efficiency_pct": 76.1, "output_kw_max": 19.3, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.003, "loss_factor_f1_kwh_per_day": 0.81911, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016841", "000031", "0", "2019/Mar/04 10:13", "Vaillant", "Vaillant", "ecoTEC plus 824", "VUW GB 246/5-5", "GC 47-044-40", "2005", "2015", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "19.3", "19.3", "", "", "88.5", "87.0", "", "76.1", "", "2", "", "", "104", "1", "2", "105", "2", "0", "", "", "", "0", "", "", "", "", "1", "6.923", "0.12", "0.003", "0.81911", "", "", "", "", "", "1", "1", "", "0045", "", "", "", "", "", "", "", "", "88.8", "97.8", "", "", "", "", "96.1"]} +{"pcdb_id": 16842, "brand_name": "Vaillant", "model_name": "ecoTEC plus 831", "model_qualifier": "VUW GB 316/5-5", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 87.0, "comparative_hot_water_efficiency_pct": 74.4, "output_kw_max": 24.4, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.003, "loss_factor_f1_kwh_per_day": 0.96947, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016842", "000031", "0", "2019/Mar/04 10:15", "Vaillant", "Vaillant", "ecoTEC plus 831", "VUW GB 316/5-5", "GC 47-044-41", "2005", "2015", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.4", "24.4", "", "", "88.7", "87.0", "", "74.4", "", "2", "", "", "104", "1", "2", "105", "2", "0", "", "", "", "0", "", "", "", "", "1", "7.074", "0.119", "0.003", "0.96947", "", "", "", "", "", "", "", "", "0045", "", "", "", "", "", "", "", "", "89.0", "98.2", "", "", "", "", "96.5"]} +{"pcdb_id": 16843, "brand_name": "Vaillant", "model_name": "ecoTEC plus 837", "model_qualifier": "VUW GB 376/5-5", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 87.0, "comparative_hot_water_efficiency_pct": 73.9, "output_kw_max": 28.6, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.003, "loss_factor_f1_kwh_per_day": 1.01583, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016843", "000031", "0", "2019/Mar/04 10:19", "Vaillant", "Vaillant", "ecoTEC plus 837", "VUW GB 376/5-5", "GC 47-044-42", "2005", "2015", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28.6", "28.6", "", "", "88.7", "87.0", "", "73.9", "", "2", "", "", "104", "1", "2", "130", "2", "0", "", "", "", "0", "", "", "", "", "1", "7.122", "0.126", "0.003", "1.01583", "", "", "", "", "", "1", "1", "", "0045", "", "", "", "", "", "", "", "", "89.0", "98.2", "", "", "", "", "96.5"]} +{"pcdb_id": 16844, "brand_name": "Vaillant", "model_name": "ecoTEC pro 28", "model_qualifier": "VUW GB 286/5-3", "winter_efficiency_pct": 89.7, "summer_efficiency_pct": 81.1, "comparative_hot_water_efficiency_pct": 63.3, "output_kw_max": 24.4, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016844", "000031", "0", "2013/Apr/08 10:03", "Vaillant", "Vaillant", "ecoTEC pro 28", "VUW GB 286/5-3", "GC 47-044-47", "2005", "2015", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24.4", "24.4", "", "", "89.7", "81.1", "", "63.3", "", "2", "1", "0", "104", "1", "2", "105", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "", "0045", "", "", "", "", "", "", "", "", "91.0", "100.2", "", "", "", "", "98.5"]} +{"pcdb_id": 16845, "brand_name": "Vaillant", "model_name": "ecoTEC plus 630", "model_qualifier": "VU GB 306/5-5", "winter_efficiency_pct": 89.7, "summer_efficiency_pct": 80.7, "comparative_hot_water_efficiency_pct": 58.9, "output_kw_max": 30.4, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016845", "000031", "0", "2012/May/30 09:06", "Vaillant", "Vaillant", "ecoTEC plus 630", "VU GB 306/5-5", "GC 47-044-67", "2005", "2015", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "30.4", "30.4", "", "", "89.7", "80.7", "", "58.9", "", "2", "1", "", "102", "1", "2", "110", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0045", "", "", "", "", "", "", "", "", "90.7", "100.4", "", "", "", "", "98.6"]} +{"pcdb_id": 16846, "brand_name": "Vaillant", "model_name": "ecoTEC plus 831", "model_qualifier": "VUW GB 316/5-5", "winter_efficiency_pct": 89.7, "summer_efficiency_pct": 81.1, "comparative_hot_water_efficiency_pct": 63.3, "output_kw_max": 24.4, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016846", "000031", "0", "2013/Apr/08 10:04", "Vaillant", "Vaillant", "ecoTEC plus 831", "VUW GB 316/5-5", "GC 47-044-41", "2005", "2015", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24.4", "24.4", "", "", "89.7", "81.1", "", "63.3", "", "2", "1", "", "104", "1", "2", "105", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "", "0045", "", "", "", "", "", "", "", "", "91.0", "100.4", "", "", "", "", "98.6"]} +{"pcdb_id": 16847, "brand_name": "Vaillant", "model_name": "ecoTEC plus 618", "model_qualifier": "VU GB 186/5-5", "winter_efficiency_pct": 89.6, "summer_efficiency_pct": 80.6, "comparative_hot_water_efficiency_pct": 58.9, "output_kw_max": 18.5, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016847", "000031", "0", "2012/May/28 10:46", "Vaillant", "Vaillant", "ecoTEC plus 618", "VU GB 186/5-5", "GC 41-044-66", "2005", "2015", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "18.5", "18.5", "", "", "89.6", "80.6", "", "58.9", "", "2", "1", "", "102", "1", "2", "100", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0045", "", "", "", "", "", "", "", "", "91.5", "99.9", "", "", "", "", "98.3"]} +{"pcdb_id": 16848, "brand_name": "Ideal", "model_name": "Esprit Eco", "model_qualifier": "24", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 62.2, "output_kw_max": 24.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016848", "000008", "0", "2012/Aug/28 09:53", "Ideal Boilers", "Ideal", "Esprit Eco", "24", "47-348-91", "2012", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "88.3", "79.7", "", "62.2", "", "2", "", "", "104", "1", "2", "146", "1", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "", "0035", "", "", "", "", "", "", "", "", "89.8", "96.9", "", "", "", "", "95.5"]} +{"pcdb_id": 16849, "brand_name": "Ideal", "model_name": "Esprit Eco", "model_qualifier": "30", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 62.3, "output_kw_max": 24.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016849", "000008", "0", "2012/Aug/28 09:53", "Ideal Boilers", "Ideal", "Esprit Eco", "30", "47-348-92", "2012", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "88.4", "79.8", "", "62.3", "", "2", "", "", "104", "1", "2", "152", "1", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "", "0035", "", "", "", "", "", "", "", "", "90.0", "96.9", "", "", "", "", "95.6"]} +{"pcdb_id": 16850, "brand_name": "Vaillant", "model_name": "ecoTEC plus 937", "model_qualifier": "VUI GB 376/5-5", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 87.0, "comparative_hot_water_efficiency_pct": 65.8, "output_kw_max": 28.6, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0, "loss_factor_f1_kwh_per_day": 1.8794, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016850", "000031", "0", "2019/Mar/04 10:22", "Vaillant", "Vaillant", "ecoTEC plus 937", "VUI GB 376/5-5", "GC 47-044-43", "2005", "2015", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28.6", "28.6", "", "", "88.7", "87.0", "", "65.8", "", "2", "", "", "104", "1", "2", "130", "2", "0", "", "", "", "0", "", "", "", "", "1", "7.998", "0.214", "0.0", "1.8794", "", "", "", "", "", "1", "1", "", "0045", "", "", "", "", "", "", "", "", "89.0", "98.2", "", "", "", "", "96.5"]} +{"pcdb_id": 16851, "brand_name": "The White Boiler Company", "model_name": "CSE30 (T)", "model_qualifier": "", "winter_efficiency_pct": 89.3, "summer_efficiency_pct": 80.7, "comparative_hot_water_efficiency_pct": 56.8, "output_kw_max": 24.1, "final_year_of_manufacture": null, "subsidiary_type": 1, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016851", "000270", "0", "2013/Apr/08 10:04", "The White Boiler Company", "The White Boiler Company", "CSE30 (T)", "", "", "2001", "current", "2", "2", "1", "2", "1", "", "", "2", "2", "2", "24.1", "24.1", "", "", "89.3", "80.7", "", "56.8", "", "2", "1", "", "104", "1", "2", "160", "3", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.4", "99.6", "", "", "", "", "97.8"]} +{"pcdb_id": 16852, "brand_name": "The White Boiler Company", "model_name": "CSE30 (T)", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 86.8, "comparative_hot_water_efficiency_pct": 75.3, "output_kw_max": 24.1, "final_year_of_manufacture": null, "subsidiary_type": 1, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0049, "loss_factor_f1_kwh_per_day": 0.86314, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016852", "000270", "0", "2012/May/28 10:32", "The White Boiler Company", "The White Boiler Company", "CSE30 (T)", "", "", "2011", "current", "1", "2", "1", "2", "1", "", "", "2", "2", "2", "24.1", "24.1", "", "", "88.3", "86.8", "", "75.3", "", "2", "", "", "104", "1", "2", "160", "3", "0", "", "", "", "0", "", "", "", "", "1", "6.9896", "0.1252", "0.0049", "0.86314", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.5", "97.4", "", "", "", "", "95.7"]} +{"pcdb_id": 16853, "brand_name": "Remeha", "model_name": "Avanta Exclusive", "model_qualifier": "39c", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 56.6, "output_kw_max": 34.8, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016853", "000005", "0", "2012/Sep/27 15:40", "Remeha", "Remeha", "Avanta Exclusive", "39c", "", "2012", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "34.8", "34.8", "", "", "89.1", "80.5", "", "56.6", "", "2", "", "", "104", "1", "2", "180", "3", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "99.6", "", "", "", "", "97.4"]} +{"pcdb_id": 16854, "brand_name": "Remeha", "model_name": "Avanta Exclusive", "model_qualifier": "35c", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 56.5, "output_kw_max": 29.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016854", "000005", "0", "2012/Sep/27 15:40", "Remeha", "Remeha", "Avanta Exclusive", "35c", "", "2012", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "29.5", "29.5", "", "", "88.9", "80.3", "", "56.5", "", "2", "", "", "104", "1", "2", "115", "3", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.5", "98.8", "", "", "", "", "96.9"]} +{"pcdb_id": 16855, "brand_name": "Remeha", "model_name": "Avanta Exclusive", "model_qualifier": "28c", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 56.2, "output_kw_max": 22.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016855", "000005", "0", "2012/Sep/27 15:40", "Remeha", "Remeha", "Avanta Exclusive", "28c", "", "2012", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "22", "22", "", "", "88.5", "79.9", "", "56.2", "", "2", "", "", "104", "1", "2", "115", "3", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.6", "97.9", "", "", "", "", "96.2"]} +{"pcdb_id": 16856, "brand_name": "HRM", "model_name": "Wallstar", "model_qualifier": "20/24 Condensing A", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 81.2, "comparative_hot_water_efficiency_pct": 59.3, "output_kw_max": 24.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016856", "000098", "0", "2012/May/30 09:10", "HRM Boilers", "HRM", "Wallstar", "20/24 Condensing A", "", "2010", "current", "4", "2", "1", "1", "0", "", "", "2", "2", "2", "20", "24", "", "", "89.0", "81.2", "", "59.3", "", "2", "", "", "201", "1", "1", "110", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "92.6", "96.7", "", "", "", "", "95.9"]} +{"pcdb_id": 16857, "brand_name": "Biasi", "model_name": "Advance Plus", "model_qualifier": "16S", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 15.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016857", "000208", "0", "2012/Jun/28 11:09", "Biasi UK", "Biasi", "Advance Plus", "16S", "41-583-22", "2012", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "15.6", "15.6", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "94", "8.6", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "96.8", "", "", "", "", "95.1"]} +{"pcdb_id": 16858, "brand_name": "Biasi", "model_name": "Advance Plus", "model_qualifier": "16S", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 15.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016858", "000208", "0", "2012/May/22 11:59", "Biasi UK", "Biasi", "Advance Plus", "16S", "", "2012", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "15.6", "15.6", "", "", "89.0", "80.0", "", "58.4", "", "2", "1", "", "102", "1", "2", "94", "8.6", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.0", "98.9", "", "", "", "", "97.2"]} +{"pcdb_id": 16859, "brand_name": "Biasi", "model_name": "Advance Plus", "model_qualifier": "25C", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 86.6, "comparative_hot_water_efficiency_pct": 74.1, "output_kw_max": 19.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0, "loss_factor_f1_kwh_per_day": 0.98922, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016859", "000208", "0", "2012/Jun/28 11:09", "Biasi UK", "Biasi", "Advance Plus", "25C", "47-583-29", "2012", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "19.5", "19.5", "", "", "88.1", "86.6", "", "74.1", "", "2", "", "", "104", "1", "2", "102", "8.6", "0", "", "", "", "0", "", "", "", "", "1", "7.11", "0.149", "0.0", "0.98922", "", "", "", "", "", "1", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "97.0", "", "", "", "", "95.3"]} +{"pcdb_id": 16860, "brand_name": "Biasi", "model_name": "Advance Plus", "model_qualifier": "25C", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 56.6, "output_kw_max": 19.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016860", "000208", "0", "2013/Apr/08 10:04", "Biasi UK", "Biasi", "Advance Plus", "25C", "", "2012", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "19.5", "19.5", "", "", "89.1", "80.5", "", "56.6", "", "2", "1", "", "104", "1", "2", "102", "8.6", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "0", "", "0005", "", "", "", "", "", "", "", "", "89.7", "99.2", "", "", "", "", "97.4"]} +{"pcdb_id": 16861, "brand_name": "Biasi", "model_name": "Advance Plus", "model_qualifier": "25S", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 24.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016861", "000208", "0", "2012/Jun/28 11:09", "Biasi UK", "Biasi", "Advance Plus", "25S", "41-583-23", "2012", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24.4", "24.4", "", "", "88.1", "79.1", "", "57.7", "", "2", "", "", "102", "1", "2", "102", "8.6", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "97.0", "", "", "", "", "95.3"]} +{"pcdb_id": 16862, "brand_name": "Biasi", "model_name": "Advance Plus", "model_qualifier": "25S", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 24.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016862", "000208", "0", "2012/May/22 12:01", "Biasi UK", "Biasi", "Advance Plus", "25S", "", "2012", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "24.4", "24.4", "", "", "89.1", "80.1", "", "58.5", "", "2", "1", "", "102", "1", "2", "102", "8.6", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.7", "99.2", "", "", "", "", "97.4"]} +{"pcdb_id": 16863, "brand_name": "Biasi", "model_name": "Advance Plus", "model_qualifier": "30C", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 86.8, "comparative_hot_water_efficiency_pct": 74.1, "output_kw_max": 24.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.002, "loss_factor_f1_kwh_per_day": 0.98571, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016863", "000208", "0", "2012/Jun/28 11:10", "Biasi UK", "Biasi", "Advance Plus", "30C", "47-583-30", "2012", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.4", "24.4", "", "", "88.0", "86.8", "", "74.1", "", "2", "", "", "104", "1", "2", "130", "8.6", "0", "", "", "", "0", "", "", "", "", "1", "7.104", "0.163", "0.002", "0.98571", "", "", "", "", "", "1", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "96.7", "", "", "", "", "95.1"]} +{"pcdb_id": 16864, "brand_name": "Biasi", "model_name": "Advance Plus", "model_qualifier": "30C", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.4, "comparative_hot_water_efficiency_pct": 56.5, "output_kw_max": 24.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016864", "000208", "0", "2013/Apr/08 10:05", "Biasi UK", "Biasi", "Advance Plus", "30C", "", "2012", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24.4", "24.4", "", "", "89.0", "80.4", "", "56.5", "", "2", "1", "", "104", "1", "2", "130", "8.6", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "0", "", "0005", "", "", "", "", "", "", "", "", "90.3", "98.8", "", "", "", "", "97.2"]} +{"pcdb_id": 16865, "brand_name": "Biasi", "model_name": "Advance Plus", "model_qualifier": "30S", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 27.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016865", "000208", "0", "2012/Jun/28 11:10", "Biasi UK", "Biasi", "Advance Plus", "30S", "41-583-24", "2012", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "27.5", "27.5", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "102", "8.6", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.5", "96.7", "", "", "", "", "95.1"]} +{"pcdb_id": 16866, "brand_name": "Biasi", "model_name": "Advance Plus", "model_qualifier": "30S", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 27.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016866", "000208", "0", "2012/May/22 12:02", "Biasi UK", "Biasi", "Advance Plus", "30S", "", "2012", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "27.5", "27.5", "", "", "89.0", "80.0", "", "58.5", "", "2", "1", "", "102", "1", "2", "102", "8.6", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.4", "98.8", "", "", "", "", "97.2"]} +{"pcdb_id": 16867, "brand_name": "Biasi", "model_name": "Advance Plus", "model_qualifier": "35C", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 86.8, "comparative_hot_water_efficiency_pct": 74.0, "output_kw_max": 29.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.002, "loss_factor_f1_kwh_per_day": 1.00577, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016867", "000208", "0", "2012/Jun/28 11:10", "Biasi UK", "Biasi", "Advance Plus", "35C", "47-583-31", "2012", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "29.5", "29.5", "", "", "88.0", "86.8", "", "74.0", "", "2", "", "", "104", "1", "2", "135", "8.6", "0", "", "", "", "0", "", "", "", "", "1", "7.12", "0.152", "0.002", "1.00577", "", "", "", "", "", "1", "", "", "0005", "", "", "", "", "", "", "", "", "88.5", "96.7", "", "", "", "", "95.1"]} +{"pcdb_id": 16868, "brand_name": "Biasi", "model_name": "Advance Plus", "model_qualifier": "35C", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.4, "comparative_hot_water_efficiency_pct": 56.6, "output_kw_max": 29.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016868", "000208", "0", "2013/Apr/08 10:05", "Biasi UK", "Biasi", "Advance Plus", "35C", "", "2012", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "29.5", "29.5", "", "", "89.0", "80.4", "", "56.6", "", "2", "1", "", "104", "1", "2", "135", "8.6", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "0", "", "0005", "", "", "", "", "", "", "", "", "90.4", "98.8", "", "", "", "", "97.2"]} +{"pcdb_id": 16869, "brand_name": "Biasi", "model_name": "Inovia", "model_qualifier": "25C", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 86.6, "comparative_hot_water_efficiency_pct": 74.1, "output_kw_max": 19.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0, "loss_factor_f1_kwh_per_day": 0.98922, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016869", "000208", "0", "2012/Jun/28 11:10", "Biasi UK", "Biasi", "Inovia", "25C", "47-583-32", "2012", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "19.5", "19.5", "", "", "88.1", "86.6", "", "74.1", "", "2", "", "", "104", "1", "2", "102", "8.6", "0", "", "", "", "0", "", "", "", "", "1", "7.11", "0.149", "0.0", "0.98922", "", "", "", "", "", "1", "1", "", "0005", "", "", "", "", "", "", "", "", "87.8", "97.0", "", "", "", "", "95.3"]} +{"pcdb_id": 16870, "brand_name": "Biasi", "model_name": "Inovia", "model_qualifier": "25C", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 62.8, "output_kw_max": 19.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016870", "000208", "0", "2013/Apr/08 10:07", "Biasi UK", "Biasi", "Inovia", "25C", "", "2012", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "19.50", "19.50", "", "", "89.1", "80.5", "", "62.8", "", "2", "1", "", "104", "1", "2", "102", "8.6", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "", "0005", "", "", "", "", "", "", "", "", "89.7", "99.2", "", "", "", "", "97.4"]} +{"pcdb_id": 16871, "brand_name": "Biasi", "model_name": "Inovia", "model_qualifier": "25S", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 24.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016871", "000208", "0", "2012/Jun/28 11:10", "Biasi UK", "Biasi", "Inovia", "25S", "41-583-26", "2012", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24.4", "24.4", "", "", "88.1", "79.1", "", "57.7", "", "2", "", "", "102", "1", "2", "102", "8.6", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "97.0", "", "", "", "", "95.3"]} +{"pcdb_id": 16872, "brand_name": "Biasi", "model_name": "Inovia", "model_qualifier": "25S", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 24.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016872", "000208", "0", "2012/May/22 12:04", "Biasi UK", "Biasi", "Inovia", "25S", "", "2012", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "24.4", "24.4", "", "", "89.1", "80.1", "", "58.5", "", "2", "1", "", "102", "1", "2", "102", "8.6", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.7", "99.2", "", "", "", "", "97.4"]} +{"pcdb_id": 16873, "brand_name": "Biasi", "model_name": "Inovia", "model_qualifier": "30C", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 86.8, "comparative_hot_water_efficiency_pct": 74.1, "output_kw_max": 24.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.002, "loss_factor_f1_kwh_per_day": 0.98571, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016873", "000208", "0", "2012/Jun/28 11:10", "Biasi UK", "Biasi", "Inovia", "30C", "47-583-33", "2012", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.4", "24.4", "", "", "88.0", "86.8", "", "74.1", "", "2", "", "", "104", "1", "2", "130", "8.6", "0", "", "", "", "0", "", "", "", "", "1", "7.104", "0.163", "0.002", "0.98571", "", "", "", "", "", "1", "1", "", "0005", "", "", "", "", "", "", "", "", "88.3", "96.7", "", "", "", "", "95.1"]} +{"pcdb_id": 16874, "brand_name": "Biasi", "model_name": "Inovia", "model_qualifier": "30C", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.4, "comparative_hot_water_efficiency_pct": 62.8, "output_kw_max": 24.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016874", "000208", "0", "2013/Apr/08 10:20", "Biasi UK", "Biasi", "Inovia", "30C", "", "2012", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24.4", "24.4", "", "", "89.0", "80.4", "", "62.8", "", "2", "1", "", "104", "1", "2", "130", "8.6", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "", "0005", "", "", "", "", "", "", "", "", "90.3", "98.8", "", "", "", "", "97.2"]} +{"pcdb_id": 16875, "brand_name": "Biasi", "model_name": "Inovia", "model_qualifier": "35C", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 86.8, "comparative_hot_water_efficiency_pct": 74.0, "output_kw_max": 29.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.002, "loss_factor_f1_kwh_per_day": 1.00577, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016875", "000208", "0", "2012/Jun/28 11:10", "Biasi UK", "Biasi", "Inovia", "35C", "47-583-34", "2012", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "29.5", "29.5", "", "", "88.0", "86.8", "", "74.0", "", "2", "", "", "104", "1", "2", "135", "8.6", "0", "", "", "", "0", "", "", "", "", "1", "7.12", "0.152", "0.002", "1.00577", "", "", "", "", "", "1", "1", "", "0005", "", "", "", "", "", "", "", "", "88.5", "96.7", "", "", "", "", "95.1"]} +{"pcdb_id": 16876, "brand_name": "Biasi", "model_name": "Inovia", "model_qualifier": "35C", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.4, "comparative_hot_water_efficiency_pct": 62.8, "output_kw_max": 29.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016876", "000208", "0", "2013/Apr/08 10:21", "Biasi UK", "Biasi", "Inovia", "35C", "", "2012", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "29.5", "29.5", "", "", "89.0", "80.4", "", "62.8", "", "2", "1", "", "104", "1", "2", "135", "8.6", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "", "0005", "", "", "", "", "", "", "", "", "90.4", "98.8", "", "", "", "", "97.2"]} +{"pcdb_id": 16877, "brand_name": "Potterton", "model_name": "Titanium", "model_qualifier": "24", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 56.1, "output_kw_max": 20.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016877", "000005", "0", "2015/Aug/06 13:08", "Baxi Heating UK", "Potterton", "Titanium", "24", "GC 47-393-39", "2012", "2015", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "20", "20", "", "", "88.4", "79.8", "", "56.1", "", "2", "", "", "104", "1", "2", "155", "5", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "90.0", "96.9", "", "", "", "", "95.6"]} +{"pcdb_id": 16878, "brand_name": "Potterton", "model_name": "Titanium", "model_qualifier": "28", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 56.1, "output_kw_max": 24.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016878", "000005", "0", "2015/Aug/06 13:08", "Baxi Heating UK", "Potterton", "Titanium", "28", "GC No 47-393-40", "2012", "2015", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "88.4", "79.8", "", "56.1", "", "2", "", "", "104", "1", "2", "155", "5", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "90.0", "96.9", "", "", "", "", "95.6"]} +{"pcdb_id": 16879, "brand_name": "Potterton", "model_name": "Titanium", "model_qualifier": "33", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 56.0, "output_kw_max": 28.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016879", "000005", "0", "2015/Aug/06 13:09", "Baxi Heating UK", "Potterton", "Titanium", "33", "GC No 47-393-41", "2012", "2015", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28", "28", "", "", "88.3", "79.7", "", "56.0", "", "2", "", "", "104", "1", "2", "160", "5", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "90.0", "96.7", "", "", "", "", "95.4"]} +{"pcdb_id": 16880, "brand_name": "Potterton", "model_name": "Titanium", "model_qualifier": "40", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 56.0, "output_kw_max": 32.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016880", "000005", "0", "2015/Aug/06 13:09", "Baxi Heating UK", "Potterton", "Titanium", "40", "GC No 47-393-42", "2012", "2015", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "32", "32", "", "", "88.3", "79.7", "", "56.0", "", "2", "", "", "104", "1", "2", "160", "5", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "90.0", "96.7", "", "", "", "", "95.4"]} +{"pcdb_id": 16881, "brand_name": "British Gas", "model_name": "539/i", "model_qualifier": "", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 63.1, "output_kw_max": 30.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016881", "000035", "0", "2012/May/22 15:44", "Bosch Thermotechnology", "British Gas", "539/i", "", "47-406-43", "2012", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "30", "30", "", "", "89.4", "80.8", "", "63.1", "", "2", "1", "", "104", "1", "2", "52", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "", "0005", "", "", "", "", "", "", "", "", "90.1", "99.9", "", "", "", "", "98.1"]} +{"pcdb_id": 16882, "brand_name": "British Gas", "model_name": "539/i", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 62.3, "output_kw_max": 30.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016882", "000035", "0", "2012/May/22 15:45", "Bosch Thermotechnology", "British Gas", "539/i", "", "47-406-42", "2012", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "30.0", "30.0", "", "", "88.4", "79.8", "", "62.3", "", "2", "", "", "104", "1", "2", "52", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "", "0005", "", "", "", "", "", "", "", "", "88.1", "97.8", "", "", "", "", "95.9"]} +{"pcdb_id": 16883, "brand_name": "British Gas", "model_name": "535/i", "model_qualifier": "", "winter_efficiency_pct": 89.5, "summer_efficiency_pct": 80.9, "comparative_hot_water_efficiency_pct": 63.2, "output_kw_max": 30.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016883", "000035", "0", "2012/May/22 15:46", "Bosch Thermotechnology", "British Gas", "535/i", "", "47-406-41", "2012", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "30.0", "30.0", "", "", "89.5", "80.9", "", "63.2", "", "2", "1", "", "104", "1", "2", "58", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "", "0005", "", "", "", "", "", "", "", "", "90.0", "100.2", "", "", "", "", "98.3"]} +{"pcdb_id": 16884, "brand_name": "British Gas", "model_name": "535/i", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 62.4, "output_kw_max": 30.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016884", "000035", "0", "2012/May/22 15:47", "Bosch Thermotechnology", "British Gas", "535/i", "", "47-406-40", "2012", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "30", "30", "", "", "88.5", "79.9", "", "62.4", "", "2", "", "", "104", "1", "2", "58", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "", "0005", "", "", "", "", "", "", "", "", "88.0", "98.0", "", "", "", "", "96.1"]} +{"pcdb_id": 16885, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "38CDi Combi", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 63.1, "output_kw_max": 30.0, "final_year_of_manufacture": 2014, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016885", "000035", "0", "2020/Sep/08 10:26", "Bosch Thermotechnology", "Worcester", "Greenstar", "38CDi Combi", "", "2012", "2014", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "30", "30", "", "", "89.4", "80.8", "", "63.1", "", "2", "1", "", "104", "1", "2", "52", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "", "0305", "", "", "", "", "", "", "", "", "90.1", "99.9", "", "", "", "", "98.1"]} +{"pcdb_id": 16886, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "38CDi Combi", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 62.3, "output_kw_max": 30.0, "final_year_of_manufacture": 2014, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016886", "000035", "0", "2020/Sep/08 10:26", "Bosch Thermotechnology", "Worcester", "Greenstar", "38CDi Combi", "", "2012", "2014", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "30.0", "30.0", "", "", "88.4", "79.8", "", "62.3", "", "2", "", "", "104", "1", "2", "52", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "", "0305", "", "", "", "", "", "", "", "", "88.1", "97.8", "", "", "", "", "95.9"]} +{"pcdb_id": 16887, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "34 CDi Combi", "winter_efficiency_pct": 89.5, "summer_efficiency_pct": 80.9, "comparative_hot_water_efficiency_pct": 63.2, "output_kw_max": 30.0, "final_year_of_manufacture": 2014, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016887", "000035", "0", "2020/Sep/08 10:26", "Bosch Thermotechnology", "Worcester", "Greenstar", "34 CDi Combi", "", "2012", "2014", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "30.0", "30.0", "", "", "89.5", "80.9", "", "63.2", "", "2", "1", "", "104", "1", "2", "58", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "", "0305", "", "", "", "", "", "", "", "", "90.0", "100.2", "", "", "", "", "98.3"]} +{"pcdb_id": 16888, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "34CDi Combi", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 62.4, "output_kw_max": 30.0, "final_year_of_manufacture": 2014, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016888", "000035", "0", "2020/Sep/08 10:26", "Bosch Thermotechnology", "Worcester", "Greenstar", "34CDi Combi", "", "2012", "2014", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "30", "30", "", "", "88.5", "79.9", "", "62.4", "", "2", "", "", "104", "1", "2", "58", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "", "0305", "", "", "", "", "", "", "", "", "88.0", "98.0", "", "", "", "", "96.1"]} +{"pcdb_id": 16889, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "29CDi Combi", "winter_efficiency_pct": 89.5, "summer_efficiency_pct": 80.9, "comparative_hot_water_efficiency_pct": 63.2, "output_kw_max": 30.0, "final_year_of_manufacture": 2014, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016889", "000035", "0", "2020/Sep/08 10:26", "Bosch Thermotechnology", "Worcester", "Greenstar", "29CDi Combi", "", "2012", "2014", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "30", "30", "", "", "89.5", "80.9", "", "63.2", "", "2", "1", "", "104", "1", "2", "58", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "", "0305", "", "", "", "", "", "", "", "", "90.0", "100.2", "", "", "", "", "98.3"]} +{"pcdb_id": 16890, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "29CDi Combi", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 62.4, "output_kw_max": 30.0, "final_year_of_manufacture": 2014, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016890", "000035", "0", "2020/Sep/08 10:35", "Bosch Thermotechnology", "Worcester", "Greenstar", "29CDi Combi", "", "2012", "2014", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "30", "30", "", "", "88.5", "79.9", "", "62.4", "", "2", "", "", "104", "1", "2", "58", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "", "0305", "", "", "", "", "", "", "", "", "88.0", "98.0", "", "", "", "", "96.1"]} +{"pcdb_id": 16891, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "24", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 86.6, "comparative_hot_water_efficiency_pct": 69.7, "output_kw_max": 20.3, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0065, "loss_factor_f1_kwh_per_day": 1.38186, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016891", "000035", "0", "2020/Sep/08 10:36", "Worcester Bosch Group", "Worcester", "Greenstar", "24", "47-406-32", "2012", "2015", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "20.3", "20.3", "", "", "88.0", "86.6", "", "69.7", "", "2", "", "", "104", "1", "2", "125", "9", "0", "", "", "", "0", "", "", "", "", "1", "7.558", "0.113", "0.0065", "1.38186", "", "", "", "", "", "", "", "", "0305", "", "", "", "", "", "", "", "", "87.8", "96.9", "", "", "", "", "95.1"]} +{"pcdb_id": 16892, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "28", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 86.6, "comparative_hot_water_efficiency_pct": 59.1, "output_kw_max": 20.3, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0296, "loss_factor_f1_kwh_per_day": 2.54937, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016892", "000035", "0", "2020/Sep/08 10:36", "Worcester Bosch Group", "Worcester", "Greenstar", "28", "47-406-33", "2012", "2015", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "20.3", "20.3", "", "", "88.0", "86.6", "", "59.1", "", "2", "", "", "104", "1", "2", "125", "9", "0", "", "", "", "0", "", "", "", "", "1", "8.913", "0.199", "0.0296", "2.54937", "", "", "", "", "", "", "", "", "0305", "", "", "", "", "", "", "", "", "87.8", "96.9", "", "", "", "", "95.1"]} +{"pcdb_id": 16893, "brand_name": "Worcester", "model_name": "GB162-65kW", "model_qualifier": "", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 65.0, "final_year_of_manufacture": 2016, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016893", "000035", "0", "2020/Sep/08 10:36", "Bosch Thermotechnology", "Worcester", "GB162-65kW", "", "", "2008", "2016", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "65", "65", "", "", "88.2", "79.2", "", "57.8", "", "2", "", "", "102", "1", "2", "99", "21", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "97.1", "", "", "", "", "95.5"]} +{"pcdb_id": 16894, "brand_name": "Heatline", "model_name": "Monza", "model_qualifier": "24a", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 62.2, "output_kw_max": 17.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016894", "000215", "0", "2012/Jun/26 14:26", "Heatline", "Heatline", "Monza", "24a", "GC 47-157-25", "2012", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "17.6", "17.6", "", "", "88.3", "79.7", "", "62.2", "", "2", "", "", "104", "1", "2", "130", "10", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "", "0005", "", "", "", "", "", "", "", "", "87.8", "97.6", "", "", "", "", "95.7"]} +{"pcdb_id": 16895, "brand_name": "Heatline", "model_name": "Monza", "model_qualifier": "28a", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 61.9, "output_kw_max": 23.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016895", "000215", "0", "2012/Jun/26 14:26", "Heatline", "Heatline", "Monza", "28a", "GC 47-157-26", "2012", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "23.2", "23.2", "", "", "87.9", "79.3", "", "61.9", "", "2", "", "", "104", "1", "2", "130", "10", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "", "0005", "", "", "", "", "", "", "", "", "87.2", "96.9", "", "", "", "", "95.1"]} +{"pcdb_id": 16896, "brand_name": "Heatline", "model_name": "CaprizPlus", "model_qualifier": "24a", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 62.2, "output_kw_max": 17.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016896", "000215", "0", "2012/Jun/26 14:26", "Heatline", "Heatline", "CaprizPlus", "24a", "GC 47-157-23", "2012", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "17.6", "17.6", "", "", "88.3", "79.7", "", "62.2", "", "2", "", "", "104", "1", "2", "130", "10", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "", "0005", "", "", "", "", "", "", "", "", "87.8", "97.6", "", "", "", "", "95.7"]} +{"pcdb_id": 16897, "brand_name": "Heatline", "model_name": "CaprizPlus", "model_qualifier": "28a", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 61.9, "output_kw_max": 23.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016897", "000215", "0", "2012/Jun/26 14:26", "Heatline", "Heatline", "CaprizPlus", "28a", "GC 47-157-24", "2012", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "23.2", "23.2", "", "", "87.9", "79.3", "", "61.9", "", "2", "", "", "104", "1", "2", "130", "10", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "", "0005", "", "", "", "", "", "", "", "", "87.2", "96.9", "", "", "", "", "95.1"]} +{"pcdb_id": 16899, "brand_name": "Morco", "model_name": "Morco 24 CPM", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 86.7, "comparative_hot_water_efficiency_pct": 71.8, "output_kw_max": 22.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0144, "loss_factor_f1_kwh_per_day": 1.1294, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016899", "000248", "0", "2012/Jul/05 08:34", "Emas Makina Sanayi", "Morco", "Morco 24 CPM", "", "", "2012", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "22.2", "22.2", "", "", "88.1", "86.7", "", "71.8", "", "2", "", "", "104", "1", "2", "127", "5", "0", "", "", "0", "0", "", "", "", "", "1", "7.3381", "0.2007", "0.0144", "1.1294", "", "", "", "", "", "1", "1", "", "0005", "", "", "", "", "", "", "", "", "87.9", "97.0", "", "", "", "", "95.3"]} +{"pcdb_id": 16900, "brand_name": "Morco", "model_name": "Morco 24 CPM", "model_qualifier": "", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 62.8, "output_kw_max": 22.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016900", "000248", "0", "2013/Apr/08 10:24", "Emas Makina Sanayi", "Morco", "Morco 24 CPM", "", "", "2012", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "22.2", "22.2", "", "", "89.1", "80.5", "", "62.8", "", "2", "1", "", "104", "1", "2", "127", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "", "0005", "", "", "", "", "", "", "", "", "89.9", "99.2", "", "", "", "", "97.4"]} +{"pcdb_id": 16901, "brand_name": "Morco", "model_name": "Morco 30 CPM", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 86.7, "comparative_hot_water_efficiency_pct": 70.5, "output_kw_max": 27.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.008, "loss_factor_f1_kwh_per_day": 1.29467, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016901", "000248", "0", "2012/Jul/05 08:34", "Emas Makina Sanayi", "Morco", "Morco 30 CPM", "", "", "2012", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "27.3", "27.3", "", "", "88.1", "86.7", "", "70.5", "", "2", "", "", "104", "1", "2", "134", "5", "0", "", "", "0", "0", "", "", "", "", "1", "7.4688", "0.225", "0.008", "1.29467", "", "", "", "", "", "1", "1", "", "0005", "", "", "", "", "", "", "", "", "88.0", "97.0", "", "", "", "", "95.3"]} +{"pcdb_id": 16902, "brand_name": "Morco", "model_name": "Morco 30 CPM", "model_qualifier": "", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.4, "comparative_hot_water_efficiency_pct": 62.8, "output_kw_max": 27.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016902", "000248", "0", "2013/Apr/08 10:24", "Emas Makina Sanayi", "Morco", "Morco 30 CPM", "", "", "2012", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "27.3", "27.3", "", "", "89.0", "80.4", "", "62.8", "", "2", "1", "", "104", "1", "2", "134", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "", "0005", "", "", "", "", "", "", "", "", "90.0", "99.0", "", "", "", "", "97.3"]} +{"pcdb_id": 16903, "brand_name": "Alpha", "model_name": "Eco", "model_qualifier": "", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 86.8, "comparative_hot_water_efficiency_pct": 79.6, "output_kw_max": 23.7, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.005, "loss_factor_f1_kwh_per_day": 0.50223, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016903", "000001", "0", "2012/Jun/27 13:03", "Alpha Therm", "Alpha", "Eco", "", "", "2012", "2015", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "23.7", "23.7", "", "", "88.2", "86.8", "", "79.6", "", "2", "", "", "104", "1", "2", "115", "6.4", "0", "", "", "", "0", "", "", "", "", "1", "6.618", "0.18", "0.005", "0.50223", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.4", "97.0", "", "", "", "", "95.4"]} +{"pcdb_id": 16904, "brand_name": "Sime", "model_name": "Brava DGT HE", "model_qualifier": "25", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 56.2, "output_kw_max": 23.9, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016904", "000213", "0", "2018/Feb/26 16:31", "Fonderie Sime S.p.A.", "Sime", "Brava DGT HE", "25", "", "2012", "2018", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "23.9", "23.9", "", "", "88.5", "79.9", "", "56.2", "", "2", "", "", "104", "1", "2", "105", "4.9", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.6", "97.9", "", "", "", "", "96.2"]} +{"pcdb_id": 16905, "brand_name": "Sime", "model_name": "Brava DGT HE", "model_qualifier": "25", "winter_efficiency_pct": 89.6, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 56.9, "output_kw_max": 23.9, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016905", "000213", "0", "2018/Feb/26 16:32", "Fonderie Sime S.p.A.", "Sime", "Brava DGT HE", "25", "", "2012", "2018", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "23.9", "23.9", "", "", "89.6", "81.0", "", "56.9", "", "2", "1", "", "104", "1", "2", "105", "4.9", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.5", "100.1", "", "", "", "", "98.3"]} +{"pcdb_id": 16906, "brand_name": "Sime", "model_name": "Brava DGT HE", "model_qualifier": "30", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 56.0, "output_kw_max": 28.9, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016906", "000213", "0", "2018/Feb/26 16:33", "Fonderie Sime S.p.A.", "Sime", "Brava DGT HE", "30", "", "2012", "2018", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28.9", "28.9", "", "", "88.3", "79.7", "", "56.0", "", "2", "", "", "104", "1", "2", "115", "4.9", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "97.4", "", "", "", "", "95.7"]} +{"pcdb_id": 16907, "brand_name": "Sime", "model_name": "Brava DGT HE", "model_qualifier": "30", "winter_efficiency_pct": 89.3, "summer_efficiency_pct": 80.7, "comparative_hot_water_efficiency_pct": 56.7, "output_kw_max": 28.9, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016907", "000213", "0", "2018/Feb/26 16:34", "Fonderie Sime S.p.A.", "Sime", "Brava DGT HE", "30", "", "2012", "2018", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "28.9", "28.9", "", "", "89.3", "80.7", "", "56.7", "", "2", "1", "", "104", "1", "2", "115", "4.9", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.3", "99.6", "", "", "", "", "97.8"]} +{"pcdb_id": 16908, "brand_name": "Ariston", "model_name": "E-Combi evo 24", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 86.6, "comparative_hot_water_efficiency_pct": 70.5, "output_kw_max": 21.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0083, "loss_factor_f1_kwh_per_day": 1.29141, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016908", "000080", "0", "2013/Jan/30 09:37", "Ariston Thermo UK", "Ariston", "E-Combi evo 24", "", "", "2012", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "21.5", "21.5", "", "", "88.1", "86.6", "", "70.5", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "", "0", "", "", "", "", "1", "7.472", "0.129", "0.0083", "1.29141", "", "", "", "", "", "1", "0", "", "0805", "", "", "", "", "", "", "", "", "87.8", "97.0", "", "", "", "", "95.3"]} +{"pcdb_id": 16909, "brand_name": "Ariston", "model_name": "E-Combi evo 30", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 86.7, "comparative_hot_water_efficiency_pct": 70.8, "output_kw_max": 27.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0076, "loss_factor_f1_kwh_per_day": 1.26812, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016909", "000080", "0", "2013/Jan/30 09:36", "Ariston Thermo UK", "Ariston", "E-Combi evo 30", "", "", "2012", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "27.3", "27.3", "", "", "88.1", "86.7", "", "70.8", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "", "0", "", "", "", "", "1", "7.441", "0.136", "0.0076", "1.26812", "", "", "", "", "", "1", "0", "", "0805", "", "", "", "", "", "", "", "", "87.9", "97.0", "", "", "", "", "95.3"]} +{"pcdb_id": 16910, "brand_name": "Ariston", "model_name": "E-Combi evo 38", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 86.7, "comparative_hot_water_efficiency_pct": 69.4, "output_kw_max": 30.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0056, "loss_factor_f1_kwh_per_day": 1.42284, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016910", "000080", "0", "2013/Jan/30 09:35", "Ariston Thermo UK", "Ariston", "E-Combi evo 38", "", "", "2012", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "30.2", "30.2", "", "", "88.1", "86.7", "", "69.4", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "", "0", "", "", "", "", "1", "7.59", "0.13", "0.0056", "1.42284", "", "", "", "", "", "1", "0", "", "0805", "", "", "", "", "", "", "", "", "87.9", "97.0", "", "", "", "", "95.3"]} +{"pcdb_id": 16911, "brand_name": "Ariston", "model_name": "Clas HE evo 24", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 86.6, "comparative_hot_water_efficiency_pct": 70.5, "output_kw_max": 21.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0083, "loss_factor_f1_kwh_per_day": 1.29141, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016911", "000080", "0", "2013/Jan/30 09:30", "Ariston Thermo UK", "Ariston", "Clas HE evo 24", "", "", "2012", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "21.5", "21.5", "", "", "88.1", "86.6", "", "70.5", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "", "0", "", "", "", "", "1", "7.472", "0.129", "0.0083", "1.29141", "", "", "", "", "", "1", "0", "", "0805", "", "", "", "", "", "", "", "", "87.8", "97.0", "", "", "", "", "95.3"]} +{"pcdb_id": 16912, "brand_name": "Ariston", "model_name": "Clas HE evo 30", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 86.7, "comparative_hot_water_efficiency_pct": 70.8, "output_kw_max": 27.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0076, "loss_factor_f1_kwh_per_day": 1.26812, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016912", "000080", "0", "2013/Jan/30 09:30", "Ariston Thermo UK", "Ariston", "Clas HE evo 30", "", "", "2012", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "27.3", "27.3", "", "", "88.1", "86.7", "", "70.8", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "", "0", "", "", "", "", "1", "7.441", "0.136", "0.0076", "1.26812", "", "", "", "", "", "1", "0", "", "0805", "", "", "", "", "", "", "", "", "87.9", "97.0", "", "", "", "", "95.3"]} +{"pcdb_id": 16913, "brand_name": "Ariston", "model_name": "Clas HE evo 38", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 86.7, "comparative_hot_water_efficiency_pct": 69.4, "output_kw_max": 30.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0056, "loss_factor_f1_kwh_per_day": 1.42284, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016913", "000080", "0", "2013/Jan/30 09:33", "Ariston Thermo UK", "Ariston", "Clas HE evo 38", "", "", "2012", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "30.2", "30.2", "", "", "88.1", "86.7", "", "69.4", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "", "0", "", "", "", "", "1", "7.59", "0.13", "0.0056", "1.42284", "", "", "", "", "", "1", "0", "", "0805", "", "", "", "", "", "", "", "", "87.9", "97.0", "", "", "", "", "95.3"]} +{"pcdb_id": 16914, "brand_name": "Ariston", "model_name": "E-System evo 24", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 21.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016914", "000080", "0", "2013/Jan/28 14:57", "Ariston Thermo UK", "Ariston", "E-System evo 24", "", "", "2012", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "21.6", "21.6", "", "", "88.1", "79.1", "", "57.8", "", "2", "", "", "102", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0805", "", "", "", "", "", "", "", "", "87.8", "97.0", "", "", "", "", "95.3"]} +{"pcdb_id": 16915, "brand_name": "Ariston", "model_name": "E-System evo 30", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 27.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016915", "000080", "0", "2013/Jan/28 14:57", "Ariston Thermo UK", "Ariston", "E-System evo 30", "", "", "2012", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "27.3", "27.3", "", "", "88.1", "79.1", "", "57.8", "", "2", "", "", "102", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0805", "", "", "", "", "", "", "", "", "87.9", "97.0", "", "", "", "", "95.3"]} +{"pcdb_id": 16916, "brand_name": "Ariston", "model_name": "Clas HE System evo 18", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 17.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016916", "000080", "0", "2013/Jan/28 14:57", "Ariston Thermo UK", "Ariston", "Clas HE System evo 18", "", "", "2012", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "17.6", "17.6", "", "", "88.1", "79.1", "", "57.8", "", "2", "", "", "102", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0805", "", "", "", "", "", "", "", "", "87.9", "97.0", "", "", "", "", "95.3"]} +{"pcdb_id": 16917, "brand_name": "Ariston", "model_name": "Clas HE System evo 24", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 21.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016917", "000080", "0", "2013/Jan/28 14:58", "Ariston Thermo UK", "Ariston", "Clas HE System evo 24", "", "", "2012", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "21.5", "21.5", "", "", "88.1", "79.1", "", "57.8", "", "2", "", "", "102", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0805", "", "", "", "", "", "", "", "", "87.8", "97.0", "", "", "", "", "95.3"]} +{"pcdb_id": 16918, "brand_name": "Ariston", "model_name": "Clas HE System evo 30", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 27.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016918", "000080", "0", "2013/Jan/28 14:58", "Ariston Thermo UK", "Ariston", "Clas HE System evo 30", "", "", "2012", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "27.3", "27.3", "", "", "88.1", "79.1", "", "57.8", "", "2", "", "", "102", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0805", "", "", "", "", "", "", "", "", "87.9", "97.0", "", "", "", "", "95.3"]} +{"pcdb_id": 16919, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "29CDi Classic", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 86.7, "comparative_hot_water_efficiency_pct": 71.2, "output_kw_max": 30.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0061, "loss_factor_f1_kwh_per_day": 1.23987, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016919", "000035", "0", "2020/Sep/08 10:36", "Bosch Thermotechnology", "Worcester", "Greenstar", "29CDi Classic", "", "2012", "2015", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "30", "30", "", "", "88.5", "86.7", "", "71.2", "", "2", "", "", "104", "1", "2", "58", "2", "0", "", "", "", "0", "", "", "", "", "1", "7.4", "0.122", "0.0061", "1.23987", "", "", "", "", "", "1", "1", "", "0305", "", "", "", "", "", "", "", "", "88.0", "98.0", "", "", "", "", "96.1"]} +{"pcdb_id": 16921, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "34CDi Classic", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 86.7, "comparative_hot_water_efficiency_pct": 72.3, "output_kw_max": 30.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0039, "loss_factor_f1_kwh_per_day": 1.13727, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016921", "000035", "0", "2020/Sep/08 10:36", "Bosch Thermotechnology", "Worcester", "Greenstar", "34CDi Classic", "", "2012", "2015", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "30", "30", "", "", "88.5", "86.7", "", "72.3", "", "2", "", "", "104", "1", "2", "58", "2", "0", "", "", "", "0", "", "", "", "", "1", "7.28", "0.123", "0.0039", "1.13727", "", "", "", "", "", "1", "1", "", "0305", "", "", "", "", "", "", "", "", "88.0", "98.0", "", "", "", "", "96.1"]} +{"pcdb_id": 16922, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "38CDi Classic", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 86.7, "comparative_hot_water_efficiency_pct": 71.5, "output_kw_max": 30.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0039, "loss_factor_f1_kwh_per_day": 1.22598, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016922", "000035", "0", "2020/Sep/08 10:36", "Bosch Thermotechnology", "Worcester", "Greenstar", "38CDi Classic", "", "2012", "2015", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "30", "30", "", "", "88.4", "86.7", "", "71.5", "", "2", "", "", "104", "1", "2", "52", "2", "0", "", "0", "", "0", "", "", "", "", "1", "7.37", "0.129", "0.0039", "1.22598", "", "", "", "", "", "1", "1", "", "0305", "", "", "", "", "", "", "", "", "88.1", "97.8", "", "", "", "", "95.9"]} +{"pcdb_id": 16923, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "42CDi Classic", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 86.7, "comparative_hot_water_efficiency_pct": 72.0, "output_kw_max": 30.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0049, "loss_factor_f1_kwh_per_day": 1.16268, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016923", "000035", "0", "2020/Sep/08 10:37", "Bosch Thermotechnology", "Worcester", "Greenstar", "42CDi Classic", "", "2012", "2015", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "30.0", "30.0", "", "", "88.8", "86.7", "", "72.0", "", "2", "", "", "104", "1", "2", "51", "2", "0", "", "", "", "0", "", "", "", "", "1", "7.31", "0.128", "0.0049", "1.16268", "", "", "", "", "", "1", "1", "", "0305", "", "", "", "", "", "", "", "", "88.1", "98.8", "", "", "", "", "96.8"]} +{"pcdb_id": 16924, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "29CDi Classic", "winter_efficiency_pct": 89.5, "summer_efficiency_pct": 80.9, "comparative_hot_water_efficiency_pct": 63.2, "output_kw_max": 30.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016924", "000035", "0", "2020/Sep/08 10:37", "Bosch Thermotechnology", "Worcester", "Greenstar", "29CDi Classic", "", "2012", "2015", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "30", "30", "", "", "89.5", "80.9", "", "63.2", "", "2", "1", "", "104", "1", "2", "58", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "", "0305", "", "", "", "", "", "", "", "", "90.0", "100.2", "", "", "", "", "98.3"]} +{"pcdb_id": 16925, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "34CDi Classic", "winter_efficiency_pct": 89.5, "summer_efficiency_pct": 80.9, "comparative_hot_water_efficiency_pct": 63.2, "output_kw_max": 30.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016925", "000035", "0", "2020/Sep/08 10:37", "Bosch Thermotechnology", "Worcester", "Greenstar", "34CDi Classic", "", "2012", "2015", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "30.0", "30.0", "", "", "89.5", "80.9", "", "63.2", "", "2", "1", "", "104", "1", "2", "58", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "", "0305", "", "", "", "", "", "", "", "", "90.0", "100.2", "", "", "", "", "98.3"]} +{"pcdb_id": 16926, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "38CDi Classic", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 63.1, "output_kw_max": 30.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016926", "000035", "0", "2020/Sep/08 10:37", "Bosch Thermotechnology", "Worcester", "Greenstar", "38CDi Classic", "", "2012", "2015", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "30.0", "30.0", "", "", "89.4", "80.8", "", "63.1", "", "2", "1", "", "104", "1", "2", "52", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "", "0305", "", "", "", "", "", "", "", "", "90.1", "99.9", "", "", "", "", "98.1"]} +{"pcdb_id": 16927, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "42CDi Classic", "winter_efficiency_pct": 89.8, "summer_efficiency_pct": 81.2, "comparative_hot_water_efficiency_pct": 63.4, "output_kw_max": 30.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016927", "000035", "0", "2020/Sep/08 10:37", "Bosch Thermotechnology", "Worcester", "Greenstar", "42CDi Classic", "", "2012", "2015", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "30.0", "30.0", "", "", "89.8", "81.2", "", "63.4", "", "2", "1", "", "104", "1", "2", "51", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "", "0305", "", "", "", "", "", "", "", "", "90.1", "101.0", "", "", "", "", "99.0"]} +{"pcdb_id": 16928, "brand_name": "Main", "model_name": "System Eco Elite", "model_qualifier": "24", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 25.94, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016928", "000005", "0", "2015/Aug/06 13:13", "Baxi Heating UK", "Main", "System Eco Elite", "24", "GC No 41-467-21", "2012", "2015", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "25.94", "25.94", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "150", "3.5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.7", "97.0", "", "", "", "", "95.7"]} +{"pcdb_id": 16929, "brand_name": "Main", "model_name": "System Eco Elite", "model_qualifier": "28", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 28.63, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016929", "000005", "0", "2015/Aug/06 13:14", "Baxi Heating UK", "Main", "System Eco Elite", "28", "GC No 41-467-22", "2012", "2015", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "28.63", "28.63", "", "", "88.1", "79.1", "", "57.8", "", "2", "", "", "102", "1", "2", "150", "3.5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "97.0", "", "", "", "", "95.3"]} +{"pcdb_id": 16930, "brand_name": "Main", "model_name": "Combi Eco Elite", "model_qualifier": "25", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 56.1, "output_kw_max": 25.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016930", "000005", "0", "2015/Aug/06 13:14", "Baxi Heating UK", "Main", "Combi Eco Elite", "25", "GC No 47-467-08", "2012", "2015", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "25", "25", "", "", "88.4", "79.8", "", "56.1", "", "2", "", "", "104", "1", "2", "150", "3.5", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "89.7", "97.0", "", "", "", "", "95.7"]} +{"pcdb_id": 16931, "brand_name": "Main", "model_name": "Combi Eco Elite", "model_qualifier": "30", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 55.9, "output_kw_max": 30.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016931", "000005", "0", "2015/Aug/06 13:15", "Baxi Heating UK", "Main", "Combi Eco Elite", "30", "GC No 47-467-09", "2012", "2015", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "30", "30", "", "", "88.1", "79.5", "", "55.9", "", "2", "", "", "104", "1", "2", "150", "3.5", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "88.0", "97.0", "", "", "", "", "95.3"]} +{"pcdb_id": 16932, "brand_name": "De Dietrich Thermique", "model_name": "EMC-M", "model_qualifier": "24", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 23.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016932", "000272", "0", "2012/Nov/12 10:42", "Remeha B.V", "De Dietrich Thermique", "EMC-M", "24", "0063CM3019", "2012", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "1", "23.4", "23.4", "", "", "88.7", "79.7", "", "58.2", "", "2", "", "", "102", "1", "2", "117", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.4", "98.5", "", "", "", "", "96.6"]} +{"pcdb_id": 16933, "brand_name": "De Dietrich Thermique", "model_name": "EMC-M", "model_qualifier": "24/28MI", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 23.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016933", "000272", "0", "2012/Nov/12 10:42", "Remeha B.V", "De Dietrich Thermique", "EMC-M", "24/28MI", "", "2012", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "23.4", "23.4", "", "", "88.6", "79.6", "", "58.2", "", "2", "", "", "102", "1", "2", "117", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "98.4", "", "", "", "", "96.4"]} +{"pcdb_id": 16934, "brand_name": "De Dietrich Thermique", "model_name": "EMC-M", "model_qualifier": "30/35MI", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 29.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016934", "000272", "0", "2012/Nov/12 10:42", "Remeha B.V", "De Dietrich Thermique", "EMC-M", "30/35MI", "", "2012", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "29.2", "29.2", "", "", "88.5", "79.5", "", "58.1", "", "2", "", "", "102", "1", "2", "145", "30", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.6", "98.2", "", "", "", "", "96.2"]} +{"pcdb_id": 16935, "brand_name": "De Dietrich Thermique", "model_name": "EMC-M", "model_qualifier": "34/39MI", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 33.8, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016935", "000272", "0", "2012/Nov/12 10:41", "Remeha B.V", "De Dietrich Thermique", "EMC-M", "34/39MI", "", "2012", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "33.8", "33.8", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "159", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.3", "98.0", "", "", "", "", "96.0"]} +{"pcdb_id": 16936, "brand_name": "De Dietrich Thermique", "model_name": "EMC-M", "model_qualifier": "24", "winter_efficiency_pct": 89.7, "summer_efficiency_pct": 80.7, "comparative_hot_water_efficiency_pct": 59.0, "output_kw_max": 23.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016936", "000272", "0", "2012/Nov/12 10:41", "Remeha B.V", "De Dietrich Thermique", "EMC-M", "24", "", "2012", "current", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "23.4", "23.4", "", "", "89.7", "80.7", "", "59.0", "", "2", "1", "", "102", "1", "2", "117", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.4", "100.7", "", "", "", "", "98.7"]} +{"pcdb_id": 16937, "brand_name": "De Dietrich Thermique", "model_name": "EMC-M", "model_qualifier": "24/28MI", "winter_efficiency_pct": 89.6, "summer_efficiency_pct": 80.6, "comparative_hot_water_efficiency_pct": 58.9, "output_kw_max": 23.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016937", "000272", "0", "2012/Nov/12 10:41", "Remeha B.V", "De Dietrich Thermique", "EMC-M", "24/28MI", "", "2012", "current", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "23.4", "23.4", "", "", "89.6", "80.6", "", "58.9", "", "2", "1", "", "102", "1", "2", "117", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.9", "100.6", "", "", "", "", "98.5"]} +{"pcdb_id": 16939, "brand_name": "De Dietrich Thermique", "model_name": "EMC-M", "model_qualifier": "30/35MI", "winter_efficiency_pct": 89.5, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 58.8, "output_kw_max": 29.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016939", "000272", "0", "2012/Nov/12 10:41", "Remeha B.V", "De Dietrich Thermique", "EMC-M", "30/35MI", "", "2012", "current", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "29.2", "29.2", "", "", "89.5", "80.5", "", "58.8", "", "2", "1", "", "102", "1", "2", "145", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.5", "100.4", "", "", "", "", "98.3"]} +{"pcdb_id": 16940, "brand_name": "De Dietrich Thermique", "model_name": "EMC-M", "model_qualifier": "34/39MI", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 80.4, "comparative_hot_water_efficiency_pct": 58.7, "output_kw_max": 33.8, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016940", "000272", "0", "2013/Feb/11 10:02", "Remeha B.V", "De Dietrich Thermique", "EMC-M", "34/39MI", "", "2012", "current", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "33.8", "33.8", "", "", "89.4", "80.4", "", "58.7", "", "2", "1", "", "102", "1", "2", "159", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.2", "100.2", "", "", "", "", "98.1"]} +{"pcdb_id": 16941, "brand_name": "Ferroli", "model_name": "Modena 18S HE", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 17.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016941", "000097", "0", "2013/Mar/28 08:32", "Ferroli", "Ferroli", "Modena 18S HE", "", "", "2012", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "17", "17", "", "", "88.5", "79.5", "", "58.1", "", "2", "", "", "102", "1", "2", "90", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "98.0", "", "", "", "", "96.2"]} +{"pcdb_id": 16942, "brand_name": "Ferroli", "model_name": "Modena 25S HE", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 24.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016942", "000097", "0", "2013/Mar/28 08:32", "Ferroli", "Ferroli", "Modena 25S HE", "", "", "2012", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24.5", "24.5", "", "", "88.6", "79.6", "", "58.1", "", "2", "", "", "102", "1", "2", "100", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.5", "98.0", "", "", "", "", "96.2"]} +{"pcdb_id": 16943, "brand_name": "Ferroli", "model_name": "Modena 25C HE", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 56.2, "output_kw_max": 24.5, "final_year_of_manufacture": 2012, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016943", "000097", "0", "2016/Apr/04 12:50", "Ferroli", "Ferroli", "Modena 25C HE", "", "", "2011", "2012", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.5", "24.5", "", "", "88.5", "79.9", "", "56.2", "", "2", "", "", "104", "1", "2", "100", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "98.0", "", "", "", "", "96.2"]} +{"pcdb_id": 16944, "brand_name": "Ferroli", "model_name": "Modena 27C HE", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 86.8, "comparative_hot_water_efficiency_pct": 71.8, "output_kw_max": 24.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0043, "loss_factor_f1_kwh_per_day": 1.20061, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016944", "000097", "0", "2016/Apr/11 08:57", "Ferroli", "Ferroli", "Modena 27C HE", "", "", "2012", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.5", "24.5", "", "", "88.6", "86.8", "", "71.8", "", "2", "", "", "104", "1", "2", "80", "3", "0", "", "", "", "0", "", "", "", "", "1", "7.3361", "0.07487", "0.0043", "1.20061", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.5", "98.0", "", "", "", "", "96.2"]} +{"pcdb_id": 16945, "brand_name": "Ferroli", "model_name": "Modena 30C HE", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 56.2, "output_kw_max": 28.9, "final_year_of_manufacture": 2012, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016945", "000097", "0", "2012/Oct/15 08:36", "Ferroli", "Ferroli", "Modena 30C HE", "", "", "2011", "2012", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28.9", "28.9", "", "", "88.6", "80.0", "", "56.2", "", "2", "", "", "104", "1", "2", "120", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.4", "98.1", "", "", "", "", "96.3"]} +{"pcdb_id": 16946, "brand_name": "Ferroli", "model_name": "Modena 32C HE", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 86.8, "comparative_hot_water_efficiency_pct": 74.6, "output_kw_max": 28.9, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0004, "loss_factor_f1_kwh_per_day": 0.95699, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016946", "000097", "0", "2016/Apr/11 08:58", "Ferroli", "Ferroli", "Modena 32C HE", "", "", "2012", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28.9", "28.9", "", "", "88.6", "86.8", "", "74.6", "", "2", "", "", "104", "1", "2", "95", "3", "0", "", "", "", "0", "", "", "", "", "1", "7.0622", "0.07685", "0.0004", "0.95699", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.4", "98.1", "", "", "", "", "96.3"]} +{"pcdb_id": 16947, "brand_name": "Fondital", "model_name": "Antea KC 28", "model_qualifier": "", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 56.3, "output_kw_max": 25.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016947", "000250", "0", "2013/Apr/08 10:25", "Fondital", "Fondital", "Antea KC 28", "", "", "2011", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "25.4", "25.4", "", "", "88.7", "80.1", "", "56.3", "", "2", "1", "", "104", "1", "2", "133", "2.3", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.8", "98.5", "", "", "", "", "96.7"]} +{"pcdb_id": 16948, "brand_name": "Fondital", "model_name": "Antea KC 28", "model_qualifier": "", "winter_efficiency_pct": 87.7, "summer_efficiency_pct": 86.3, "comparative_hot_water_efficiency_pct": 75.0, "output_kw_max": 25.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0085, "loss_factor_f1_kwh_per_day": 0.83037, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016948", "000250", "0", "2012/Nov/29 12:57", "Fondital", "Fondital", "Antea KC 28", "", "", "2011", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "25.4", "25.4", "", "", "87.7", "86.3", "", "75.0", "", "2", "", "", "104", "1", "2", "133", "2.3", "0", "", "", "", "0", "", "", "", "", "1", "7.02", "0.072", "0.0085", "0.83037", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "86.9", "96.4", "", "", "", "", "94.6"]} +{"pcdb_id": 16949, "brand_name": "Fondital", "model_name": "Antea KR 28", "model_qualifier": "", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 25.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016949", "000250", "0", "2012/Nov/29 12:57", "Fondital", "Fondital", "Antea KR 28", "", "", "2011", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "25.4", "25.4", "", "", "88.7", "79.7", "", "58.2", "", "2", "1", "", "102", "1", "2", "133", "2.3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.8", "98.5", "", "", "", "", "96.7"]} +{"pcdb_id": 16950, "brand_name": "Fondital", "model_name": "Antea KR 28", "model_qualifier": "", "winter_efficiency_pct": 87.7, "summer_efficiency_pct": 78.7, "comparative_hot_water_efficiency_pct": 57.5, "output_kw_max": 25.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016950", "000250", "0", "2012/Nov/29 12:58", "Fondital", "Fondital", "Antea KR 28", "", "", "2011", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "25.4", "25.4", "", "", "87.7", "78.7", "", "57.5", "", "2", "", "", "102", "1", "2", "133", "2.3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "86.9", "96.4", "", "", "", "", "94.6"]} +{"pcdb_id": 16951, "brand_name": "Fondital", "model_name": "Itaca KC 24", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 56.2, "output_kw_max": 22.9, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016951", "000250", "0", "2012/Nov/29 12:58", "Fondital", "Fondital", "Itaca KC 24", "", "", "2012", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "22.9", "22.9", "", "", "88.5", "79.9", "", "56.2", "", "2", "1", "", "104", "1", "2", "121", "2.4", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.1", "98.1", "", "", "", "", "96.4"]} +{"pcdb_id": 16952, "brand_name": "Fondital", "model_name": "Itaca KC 24", "model_qualifier": "", "winter_efficiency_pct": 87.5, "summer_efficiency_pct": 88.2, "comparative_hot_water_efficiency_pct": 74.3, "output_kw_max": 22.9, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 3, "rejected_energy_proportion_r1": 0.0011, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": 0.95054, "rejected_factor_f3_per_litre": 4e-05, "raw": ["016952", "000250", "0", "2020/Apr/09 16:27", "Fondital", "Fondital", "Itaca KC 24", "", "", "2012", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "22.9", "22.9", "", "", "87.5", "88.2", "", "74.3", "", "2", "", "", "104", "1", "2", "121", "2.4", "0", "", "", "", "0", "", "", "", "", "3", "7.09", "0.083", "0.0011", "", "3.42", "0.078", "0.0034", "0.95054", "0.00004", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.1", "96.0", "", "", "", "", "94.3"]} +{"pcdb_id": 16954, "brand_name": "Fondital", "model_name": "Itaca KC 28", "model_qualifier": "", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 62.5, "output_kw_max": 25.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016954", "000250", "0", "2012/Nov/29 12:59", "Fondital", "Fondital", "Itaca KC 28", "", "", "2012", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "25.4", "25.4", "", "", "88.7", "80.1", "", "62.5", "", "2", "1", "", "104", "1", "2", "121", "2.4", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "", "0005", "", "", "", "", "", "", "", "", "88.8", "98.5", "", "", "", "", "96.7"]} +{"pcdb_id": 16955, "brand_name": "Fondital", "model_name": "Itaca KC 28", "model_qualifier": "", "winter_efficiency_pct": 87.7, "summer_efficiency_pct": 81.7, "comparative_hot_water_efficiency_pct": 59.4, "output_kw_max": 25.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 3, "rejected_energy_proportion_r1": 0.0236, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": 1.89165, "rejected_factor_f3_per_litre": -0.00022, "raw": ["016955", "000250", "0", "2020/Apr/09 16:27", "Fondital", "Fondital", "Itaca KC 28", "", "", "2012", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "25.4", "25.4", "", "", "87.7", "81.7", "", "59.4", "", "2", "", "", "104", "1", "2", "121", "2.4", "0", "", "", "", "0", "", "", "", "", "3", "8.86", "0.171", "0.0236", "", "4.6", "0.165", "0.0092", "1.89165", "-0.00022", "1", "1", "", "0005", "", "", "", "", "", "", "", "", "86.9", "96.4", "", "", "", "", "94.6"]} +{"pcdb_id": 16956, "brand_name": "Fondital", "model_name": "Itaca KC 32", "model_qualifier": "", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 80.6, "comparative_hot_water_efficiency_pct": 62.9, "output_kw_max": 29.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016956", "000250", "0", "2012/Nov/29 13:02", "Fondital", "Fondital", "Itaca KC 32", "", "", "2012", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "29.4", "29.4", "", "", "89.2", "80.6", "", "62.9", "", "2", "1", "", "104", "1", "2", "121", "2.4", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "", "0005", "", "", "", "", "", "", "", "", "89.2", "99.7", "", "", "", "", "97.7"]} +{"pcdb_id": 16957, "brand_name": "Fondital", "model_name": "Itaca KC 32", "model_qualifier": "", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 81.7, "comparative_hot_water_efficiency_pct": 59.4, "output_kw_max": 29.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 3, "rejected_energy_proportion_r1": 0.0236, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": 1.89165, "rejected_factor_f3_per_litre": -0.00022, "raw": ["016957", "000250", "0", "2020/Apr/09 16:26", "Fondital", "Fondital", "Itaca KC 32", "", "", "2012", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "29.4", "29.4", "", "", "88.2", "81.7", "", "59.4", "", "2", "", "", "104", "1", "2", "121", "2.4", "0", "", "", "", "0", "", "", "", "", "3", "8.86", "0.171", "0.0236", "", "4.6", "0.165", "0.0092", "1.89165", "-0.00022", "1", "1", "", "0005", "", "", "", "", "", "", "", "", "87.2", "97.6", "", "", "", "", "95.6"]} +{"pcdb_id": 16958, "brand_name": "Fondital", "model_name": "Itaca KR 24", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 22.9, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016958", "000250", "0", "2012/Nov/29 13:03", "Fondital", "Fondital", "Itaca KR 24", "", "", "2012", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "22.9", "22.9", "", "", "88.5", "79.5", "", "58.1", "", "2", "1", "", "102", "1", "2", "121", "2.4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.1", "98.1", "", "", "", "", "96.4"]} +{"pcdb_id": 16959, "brand_name": "Fondital", "model_name": "Itaca KR 24", "model_qualifier": "", "winter_efficiency_pct": 87.5, "summer_efficiency_pct": 78.5, "comparative_hot_water_efficiency_pct": 57.4, "output_kw_max": 22.9, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016959", "000250", "0", "2012/Nov/29 13:03", "Fondital", "Fondital", "Itaca KR 24", "", "", "2012", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "22.9", "22.9", "", "", "87.5", "78.5", "", "57.4", "", "2", "", "", "102", "1", "2", "121", "2.4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.1", "96.0", "", "", "", "", "94.3"]} +{"pcdb_id": 16960, "brand_name": "Fondital", "model_name": "Itaca KR 32", "model_qualifier": "", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 29.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016960", "000250", "0", "2012/Nov/29 13:04", "Fondital", "Fondital", "Itaca KR 32", "", "", "2012", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "29.4", "29.4", "", "", "89.2", "80.2", "", "58.6", "", "2", "1", "", "102", "1", "2", "121", "2.4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.2", "99.7", "", "", "", "", "97.7"]} +{"pcdb_id": 16961, "brand_name": "Fondital", "model_name": "Itaca KR 32", "model_qualifier": "", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 29.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016961", "000250", "0", "2012/Nov/29 13:06", "Fondital", "Fondital", "Itaca KR 32", "", "", "2012", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "29.4", "29.4", "", "", "88.2", "79.2", "", "57.8", "", "2", "", "", "102", "1", "2", "121", "2.4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.2", "97.6", "", "", "", "", "95.6"]} +{"pcdb_id": 16962, "brand_name": "iQE", "model_name": "Simplicity", "model_qualifier": "20T", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 19.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016962", "000273", "0", "2015/Oct/01 13:32", "Fonderie Sime S.p.A.", "iQE", "Simplicity", "20T", "41-283-35", "2012", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "19.0", "19.0", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "120", "8", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.2", "96.8", "", "", "", "", "95.1"]} +{"pcdb_id": 16963, "brand_name": "iQE", "model_name": "Simplicity", "model_qualifier": "20T", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 19.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016963", "000273", "0", "2015/Oct/01 13:32", "Fonderie Sime S.p.A.", "iQE", "Simplicity", "20T", "", "2012", "current", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "19.0", "19.0", "", "", "89.0", "80.0", "", "58.5", "", "2", "1", "", "102", "1", "2", "120", "8", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.2", "98.9", "", "", "", "", "97.3"]} +{"pcdb_id": 16964, "brand_name": "iQE", "model_name": "Simplicity", "model_qualifier": "25", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 56.0, "output_kw_max": 23.9, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016964", "000273", "0", "2015/Oct/01 13:33", "Fonderie Sime S.p.A.", "iQE", "Simplicity", "25", "47-283-41", "2009", "current", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "23.9", "23.9", "", "", "88.2", "79.6", "", "56.0", "", "2", "", "", "104", "1", "2", "125", "8", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.5", "97.1", "", "", "", "", "95.5"]} +{"pcdb_id": 16965, "brand_name": "iQE", "model_name": "Simplicity", "model_qualifier": "25", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 80.6, "comparative_hot_water_efficiency_pct": 56.7, "output_kw_max": 23.9, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016965", "000273", "0", "2015/Oct/01 13:34", "Fonderie Sime S.p.A.", "iQE", "Simplicity", "25", "", "2009", "current", "2", "2", "1", "2", "0", "", "", "2", "3", "2", "23.9", "23.9", "", "", "89.2", "80.6", "", "56.7", "", "2", "1", "", "104", "1", "2", "125", "8", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.4", "99.3", "", "", "", "", "97.6"]} +{"pcdb_id": 16966, "brand_name": "iQE", "model_name": "Simplicity", "model_qualifier": "25T", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 23.9, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016966", "000273", "0", "2015/Oct/01 13:35", "Fonderie Sime S.p.A.", "iQE", "Simplicity", "25T", "41-283-36", "2012", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "23.9", "23.9", "", "", "88.2", "79.2", "", "57.9", "", "2", "", "", "102", "1", "2", "125", "8", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.5", "97.1", "", "", "", "", "95.5"]} +{"pcdb_id": 16967, "brand_name": "iQE", "model_name": "Simplicity", "model_qualifier": "25T", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 23.9, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016967", "000273", "0", "2015/Oct/01 13:35", "Fonderie Sime S.p.A.", "iQE", "Simplicity", "25T", "", "2012", "current", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "23.9", "23.9", "", "", "89.2", "80.2", "", "58.6", "", "2", "1", "", "102", "1", "2", "125", "8", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.4", "99.3", "", "", "", "", "97.6"]} +{"pcdb_id": 16968, "brand_name": "iQE", "model_name": "Simplicity", "model_qualifier": "30T", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": null, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016968", "000273", "0", "2015/Oct/01 13:36", "Fonderie Sime S.p.A.", "iQE", "Simplicity", "30T", "41-283-37", "2012", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "28.9", ">70kW", "", "", "88.2", "79.2", "", "57.9", "", "2", "", "", "102", "1", "2", "130", "8", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.7", "97.0", "", "", "", "", "95.4"]} +{"pcdb_id": 16969, "brand_name": "iQE", "model_name": "Simplicity", "model_qualifier": "30T", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 28.9, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016969", "000273", "0", "2015/Oct/01 13:37", "Fonderie Sime S.p.A.", "iQE", "Simplicity", "30T", "", "2012", "current", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "28.9", "28.9", "", "", "89.2", "80.2", "", "58.6", "", "2", "1", "", "102", "1", "2", "130", "8", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.6", "99.2", "", "", "", "", "97.6"]} +{"pcdb_id": 16970, "brand_name": "iQE", "model_name": "Simplicity", "model_qualifier": "30", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 56.0, "output_kw_max": 28.9, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016970", "000273", "0", "2015/Oct/01 13:39", "Fonderie Sime S.p.A.", "iQE", "Simplicity", "30", "47-283-42", "2012", "current", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "28.9", "28.9", "", "", "88.2", "79.6", "", "56.0", "", "2", "", "", "104", "1", "2", "130", "8", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.7", "97.0", "", "", "", "", "95.4"]} +{"pcdb_id": 16971, "brand_name": "iQE", "model_name": "Simplicity", "model_qualifier": "30", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 80.6, "comparative_hot_water_efficiency_pct": 56.7, "output_kw_max": 28.9, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016971", "000273", "0", "2015/Oct/01 13:40", "Fonderie Sime S.p.A.", "iQE", "Simplicity", "30", "", "2012", "current", "2", "2", "1", "2", "0", "", "", "2", "3", "2", "28.9", "28.9", "", "", "89.2", "80.6", "", "56.7", "", "2", "1", "", "104", "1", "2", "130", "8", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.6", "99.2", "", "", "", "", "97.6"]} +{"pcdb_id": 16972, "brand_name": "iQE", "model_name": "Simplicity", "model_qualifier": "35", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 55.8, "output_kw_max": 34.1, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016972", "000273", "0", "2015/Oct/01 13:41", "Fonderie Sime S.p.A.", "iQE", "Simplicity", "35", "47-283-43", "2012", "current", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "34.1", "34.1", "", "", "88.0", "79.4", "", "55.8", "", "2", "", "", "104", "1", "2", "140", "8", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.5", "96.2", "", "", "", "", "94.9"]} +{"pcdb_id": 16973, "brand_name": "iQE", "model_name": "Simplicity", "model_qualifier": "35", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.4, "comparative_hot_water_efficiency_pct": 56.6, "output_kw_max": 34.1, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016973", "000273", "0", "2015/Oct/01 13:43", "Fonderie Sime S.p.A.", "iQE", "Simplicity", "35", "", "2012", "current", "2", "2", "1", "2", "0", "", "", "2", "3", "2", "34.1", "34.1", "", "", "89.0", "80.4", "", "56.6", "", "2", "1", "", "104", "1", "2", "140", "8", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "91.5", "98.4", "", "", "", "", "97.1"]} +{"pcdb_id": 16974, "brand_name": "Vokera", "model_name": "Vision", "model_qualifier": "20S", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 19.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016974", "000011", "0", "2012/Nov/07 12:42", "Vokera", "Vokera", "Vision", "20S", "41 094 76", "2012", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "19.50", "19.50", "", "", "88.5", "79.5", "", "58.1", "", "2", "", "", "102", "1", "2", "96", "4.5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "87.8", "98.1", "", "", "", "", "96.2"]} +{"pcdb_id": 16975, "brand_name": "Vokera", "model_name": "Vision", "model_qualifier": "25S", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 24.45, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016975", "000011", "0", "2012/Nov/07 12:43", "Vokera", "Vokera", "Vision", "25S", "41 094 77", "2012", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "24.45", "24.45", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "107", "4.5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "88.1", "97.7", "", "", "", "", "95.9"]} +{"pcdb_id": 16976, "brand_name": "Vokera", "model_name": "Vision", "model_qualifier": "25C", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 86.6, "comparative_hot_water_efficiency_pct": 72.0, "output_kw_max": 19.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.003, "loss_factor_f1_kwh_per_day": 1.17113, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016976", "000011", "0", "2014/Oct/15 10:57", "Vokera", "Vokera", "Vision", "25C", "47 364 10", "2012", "current", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "19.5", "19.5", "", "", "88.5", "86.6", "", "72.0", "", "2", "", "", "104", "1", "2", "110", "4.5", "0", "", "", "", "0", "", "", "", "", "1", "7.315", "0.105", "0.003", "1.17113", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "", "", "", "", "87.8", "98.1", "", "", "", "", "96.2"]} +{"pcdb_id": 16977, "brand_name": "Vokera", "model_name": "Vision", "model_qualifier": "30C", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 86.7, "comparative_hot_water_efficiency_pct": 71.9, "output_kw_max": 24.45, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.003, "loss_factor_f1_kwh_per_day": 1.18793, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016977", "000011", "0", "2014/Oct/15 10:58", "Vokera", "Vokera", "Vision", "30C", "47 364 11", "2012", "current", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "24.45", "24.45", "", "", "88.4", "86.7", "", "71.9", "", "2", "", "", "104", "1", "2", "119", "4.5", "0", "", "", "", "0", "", "", "", "", "1", "7.325", "0.103", "0.003", "1.18793", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "", "", "", "", "88.1", "97.7", "", "", "", "", "95.9"]} +{"pcdb_id": 16978, "brand_name": "Sime", "model_name": "Brava DGT HE", "model_qualifier": "35", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 56.2, "output_kw_max": 34.1, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016978", "000213", "0", "2018/Feb/26 16:35", "Fonderie Sime S.p.A.", "Sime", "Brava DGT HE", "35", "47-283-40", "2012", "2018", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "34.1", "34.1", "", "", "88.5", "79.9", "", "56.2", "", "2", "", "", "104", "1", "2", "135", "4.9", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.7", "97.8", "", "", "", "", "96.0"]} +{"pcdb_id": 16979, "brand_name": "Sime", "model_name": "Brava DGT HE", "model_qualifier": "35", "winter_efficiency_pct": 89.5, "summer_efficiency_pct": 80.9, "comparative_hot_water_efficiency_pct": 56.9, "output_kw_max": 34.1, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016979", "000213", "0", "2018/Feb/26 16:34", "Fonderie Sime S.p.A.", "Sime", "Brava DGT HE", "35", "", "2012", "2018", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "34.1", "34.1", "", "", "89.5", "80.9", "", "56.9", "", "2", "1", "", "104", "1", "2", "135", "4.9", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.7", "99.9", "", "", "", "", "98.2"]} +{"pcdb_id": 16980, "brand_name": "Johnson & Starley", "model_name": "QuanTec", "model_qualifier": "HR28C", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 86.6, "comparative_hot_water_efficiency_pct": 85.4, "output_kw_max": 21.1, "final_year_of_manufacture": null, "subsidiary_type": 1, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0044, "loss_factor_f1_kwh_per_day": 0.06006, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016980", "000239", "0", "2015/Sep/22 16:29", "Johnson & Starley", "Johnson & Starley", "QuanTec", "HR28C", "47-416-11", "2012", "current", "1", "2", "1", "2", "1", "", "", "2", "2", "2", "21.1", "21.1", "", "", "88.7", "86.6", "", "85.4", "", "2", "", "", "104", "1", "2", "100", "2.17", "0", "", "", "", "0", "", "", "", "", "1", "6.1677", "0.1349", "0.0044", "0.06006", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "", "", "", "", "87.8", "98.7", "", "", "", "", "96.7"]} +{"pcdb_id": 16982, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "32 CDi Compact", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 87.9, "comparative_hot_water_efficiency_pct": 72.7, "output_kw_max": 24.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.0017, "loss_factor_f1_kwh_per_day": 1.13266, "loss_factor_f2_kwh_per_day": 1.06911, "rejected_factor_f3_per_litre": 1e-05, "raw": ["016982", "000035", "0", "2020/Sep/08 10:37", "Bosch Thermotechnology", "Worcester", "Greenstar", "32 CDi Compact", "47-406-46", "2012", "2015", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "89.2", "87.9", "", "72.7", "", "2", "", "", "104", "1", "2", "121", "1.0", "0", "", "", "", "0", "", "", "", "", "2", "7.24", "0.088", "0.0017", "1.13266", "13.19", "0.109", "0.0006", "1.06911", "0.00001", "1", "1", "", "0305", "", "", "", "", "", "", "", "", "88.8", "99.6", "", "", "", "", "97.5"]} +{"pcdb_id": 16983, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "28 CDi Compact", "winter_efficiency_pct": 90.3, "summer_efficiency_pct": 90.3, "comparative_hot_water_efficiency_pct": 74.7, "output_kw_max": 24.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.0014, "loss_factor_f1_kwh_per_day": 1.10575, "loss_factor_f2_kwh_per_day": 1.07482, "rejected_factor_f3_per_litre": 0.0, "raw": ["016983", "000035", "0", "2020/Sep/08 10:37", "Bosch Thermotechnology", "Worcester", "Greenstar", "28 CDi Compact", "47-406-45", "2012", "2015", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "90.3", "90.3", "", "74.7", "", "2", "1", "", "104", "1", "2", "108", "1.0", "0", "", "", "", "0", "", "", "", "", "2", "7.21", "0.087", "0.0014", "1.10575", "13.13", "0.107", "0.0009", "1.07482", "0.0", "1", "1", "", "0305", "", "", "", "", "", "", "", "", "90.8", "101.8", "", "", "", "", "99.7"]} +{"pcdb_id": 16984, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "32 CDi Compact", "winter_efficiency_pct": 90.3, "summer_efficiency_pct": 90.3, "comparative_hot_water_efficiency_pct": 73.7, "output_kw_max": 24.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.0007, "loss_factor_f1_kwh_per_day": 1.19641, "loss_factor_f2_kwh_per_day": 1.16509, "rejected_factor_f3_per_litre": 0.0, "raw": ["016984", "000035", "0", "2020/Sep/08 10:37", "Bosch Thermotechnology", "Worcester", "Greenstar", "32 CDi Compact", "47-406-47", "2012", "2015", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "90.3", "90.3", "", "73.7", "", "2", "1", "", "104", "1", "2", "120", "1.0", "0", "", "", "", "0", "", "", "", "", "2", "7.3", "0.089", "0.0007", "1.19641", "13.15", "0.106", "0.0008", "1.16509", "0.0", "1", "1", "", "0305", "", "", "", "", "", "", "", "", "90.8", "101.8", "", "", "", "", "99.7"]} +{"pcdb_id": 16985, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "36 CDi Compact", "winter_efficiency_pct": 90.3, "summer_efficiency_pct": 90.3, "comparative_hot_water_efficiency_pct": 73.4, "output_kw_max": 24.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.0021, "loss_factor_f1_kwh_per_day": 1.21747, "loss_factor_f2_kwh_per_day": 1.18603, "rejected_factor_f3_per_litre": 1e-05, "raw": ["016985", "000035", "0", "2020/Sep/08 10:38", "Bosch Thermotechnology", "Worcester", "Greenstar", "36 CDi Compact", "47-406-49", "2012", "2015", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "90.3", "90.3", "", "73.4", "", "2", "1", "", "104", "1", "2", "134", "1.0", "0", "", "", "", "0", "", "", "", "", "2", "7.33", "0.088", "0.0021", "1.21747", "13.17", "0.107", "0.0008", "1.18603", "0.00001", "1", "1", "", "0305", "", "", "", "", "", "", "", "", "90.8", "101.8", "", "", "", "", "99.7"]} +{"pcdb_id": 16986, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "28 CDi Compact", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 87.5, "comparative_hot_water_efficiency_pct": 73.9, "output_kw_max": 24.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.0014, "loss_factor_f1_kwh_per_day": 1.02854, "loss_factor_f2_kwh_per_day": 0.93618, "rejected_factor_f3_per_litre": 1e-05, "raw": ["016986", "000035", "0", "2020/Sep/08 10:38", "Bosch Thermotechnology", "Worcester", "Greenstar", "28 CDi Compact", "47-406-44", "2012", "2015", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "89.2", "87.5", "", "73.9", "", "2", "", "", "104", "1", "2", "108", "1.0", "0", "", "", "", "0", "", "", "", "", "2", "7.13", "0.087", "0.0014", "1.02854", "13.11", "0.108", "0.0007", "0.93618", "0.00001", "1", "1", "", "0305", "", "", "", "", "", "", "", "", "88.8", "99.6", "", "", "", "", "97.5"]} +{"pcdb_id": 16987, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "36 CDi Compact", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 88.2, "comparative_hot_water_efficiency_pct": 72.4, "output_kw_max": 24.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.0011, "loss_factor_f1_kwh_per_day": 1.16541, "loss_factor_f2_kwh_per_day": 1.12322, "rejected_factor_f3_per_litre": -1e-05, "raw": ["016987", "000035", "0", "2020/Apr/09 16:29", "Bosch Thermotechnology", "Worcester", "Greenstar", "36 CDi Compact", "47-406-48", "2012", "2015", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "89.2", "88.2", "", "72.4", "", "2", "", "", "104", "1", "2", "130", "1.0", "0", "", "", "", "0", "", "", "", "", "2", "7.27", "0.088", "0.0011", "1.16541", "12.54", "0.099", "0.0017", "1.12322", "-0.00001", "1", "1", "", "0305", "", "", "", "", "", "", "", "", "88.8", "99.6", "", "", "", "", "97.5"]} +{"pcdb_id": 16988, "brand_name": "Baxi", "model_name": "Neta-tec Plus", "model_qualifier": "24 GA", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 77.6, "output_kw_max": 20.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0043, "loss_factor_f1_kwh_per_day": 0.70793, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016988", "000005", "0", "2015/Aug/06 12:10", "Baxi", "Baxi", "Neta-tec Plus", "24 GA", "", "2011", "2015", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "20", "20", "", "", "88.4", "87.3", "", "77.6", "", "2", "", "", "104", "1", "2", "104", "3.5", "0", "", "", "", "0", "", "", "", "", "1", "6.786", "0.118", "0.0043", "0.70793", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "90.0", "96.9", "", "", "", "", "95.6"]} +{"pcdb_id": 16989, "brand_name": "Baxi", "model_name": "Neta-tec Plus", "model_qualifier": "28 GA", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 77.3, "output_kw_max": 24.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0044, "loss_factor_f1_kwh_per_day": 0.73349, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016989", "000005", "0", "2015/Aug/06 12:11", "Baxi Heating UK", "Baxi", "Neta-tec Plus", "28 GA", "", "", "2015", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "88.4", "87.3", "", "77.3", "", "2", "", "", "104", "1", "2", "116", "3.5", "0", "", "", "", "0", "", "", "", "", "1", "6.813", "0.118", "0.0044", "0.73349", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "90.0", "96.9", "", "", "", "", "95.6"]} +{"pcdb_id": 16990, "brand_name": "Baxi", "model_name": "Neta-tec Plus", "model_qualifier": "33 GA", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 77.2, "output_kw_max": 28.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0045, "loss_factor_f1_kwh_per_day": 0.74098, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016990", "000005", "0", "2015/Aug/06 12:11", "Baxi Heating UK", "Baxi", "Neta-tec Plus", "33 GA", "", "2011", "2015", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28", "28", "", "", "88.4", "87.3", "", "77.2", "", "2", "", "", "104", "1", "2", "133", "3.5", "0", "", "", "", "0", "", "", "", "", "1", "6.821", "0.106", "0.0045", "0.74098", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "90.0", "97.0", "", "", "", "", "95.7"]} +{"pcdb_id": 16991, "brand_name": "Baxi", "model_name": "Neta-tec Plus", "model_qualifier": "24 GA", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 56.8, "output_kw_max": 20.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016991", "000005", "0", "2012/Nov/29 08:50", "Baxi Heating UK", "Baxi", "Neta-tec Plus", "24 GA", "", "2011", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "20", "20", "", "", "89.4", "80.8", "", "56.8", "", "2", "1", "", "104", "1", "2", "104", "3.5", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "92.0", "99.1", "", "", "", "", "97.8"]} +{"pcdb_id": 16992, "brand_name": "Baxi", "model_name": "Neta-tec Plus", "model_qualifier": "28 GA", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 56.8, "output_kw_max": 24.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016992", "000005", "0", "2012/Nov/29 08:50", "Baxi Heating UK", "Baxi", "Neta-tec Plus", "28 GA", "", "2011", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "89.4", "80.8", "", "56.8", "", "2", "1", "", "104", "1", "2", "116", "3.5", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "92.0", "99.1", "", "", "", "", "97.8"]} +{"pcdb_id": 16993, "brand_name": "Baxi", "model_name": "Neta-tec Plus", "model_qualifier": "33 GA", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 56.8, "output_kw_max": 28.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016993", "000005", "0", "2012/Nov/29 08:51", "Baxi Heating UK", "Baxi", "Neta-tec Plus", "33 GA", "", "2011", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "28", "28", "", "", "89.4", "80.8", "", "56.8", "", "2", "1", "", "104", "1", "2", "133", "3.5", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "92.0", "99.2", "", "", "", "", "97.8"]} +{"pcdb_id": 16994, "brand_name": "Viessmann", "model_name": "Vitodens 100-W", "model_qualifier": "WB1C 19kW System Boiler", "winter_efficiency_pct": 89.5, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 58.8, "output_kw_max": 17.3, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016994", "000033", "0", "2013/Sep/20 08:26", "Viessmann", "Viessmann", "Vitodens 100-W", "WB1C 19kW System Boiler", "", "2012", "2015", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "17.3", "17.3", "", "", "89.5", "80.5", "", "58.8", "", "2", "1", "", "102", "1", "2", "77.0", "4.92", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.2", "100.1", "", "", "", "", "98.2"]} +{"pcdb_id": 16995, "brand_name": "Viessmann", "model_name": "Vitodens 100-W", "model_qualifier": "WB1C 19kW System Boiler", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 17.3, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016995", "000033", "0", "2013/Sep/20 08:25", "Viessmann", "Viessmann", "Vitodens 100-W", "WB1C 19kW System Boiler", "", "2012", "2015", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "17.3", "17.3", "", "", "88.5", "79.5", "", "58.1", "", "2", "", "", "102", "1", "2", "77.0", "4.92", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.2", "97.9", "", "", "", "", "96.1"]} +{"pcdb_id": 16996, "brand_name": "Viessmann", "model_name": "Vitodens 100-W", "model_qualifier": "WB1C 35kW System Boiler", "winter_efficiency_pct": 89.7, "summer_efficiency_pct": 80.7, "comparative_hot_water_efficiency_pct": 59.0, "output_kw_max": 31.9, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016996", "000033", "0", "2013/Sep/20 08:14", "Viessmann", "Viessmann", "Vitodens 100-W", "WB1C 35kW System Boiler", "", "2012", "2015", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "31.9", "31.9", "", "", "89.7", "80.7", "", "59.0", "", "2", "1", "", "102", "1", "2", "143", "4.76", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.2", "100.7", "", "", "", "", "98.7"]} +{"pcdb_id": 16997, "brand_name": "Viessmann", "model_name": "Vitodens 100-W", "model_qualifier": "WB1C 35kW System Boiler", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 31.9, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016997", "000033", "0", "2013/Sep/20 08:14", "Viessmann", "Viessmann", "Vitodens 100-W", "WB1C 35kW System Boiler", "", "2012", "2015", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "31.9", "31.9", "", "", "88.7", "79.7", "", "58.2", "", "2", "", "", "102", "1", "2", "143", "4.76", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.2", "98.5", "", "", "", "", "96.5"]} +{"pcdb_id": 16998, "brand_name": "Viessmann", "model_name": "Vitodens 100-W", "model_qualifier": "WB1C 26kW System Boiler", "winter_efficiency_pct": 89.5, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 58.8, "output_kw_max": 23.7, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016998", "000033", "0", "2013/Sep/20 08:23", "Viessmann", "Viessmann", "Vitodens 100-W", "WB1C 26kW System Boiler", "", "2012", "2015", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "23.7", "23.7", "", "", "89.5", "80.5", "", "58.8", "", "2", "1", "", "102", "1", "2", "87.3", "4.92", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.3", "100.0", "", "", "", "", "98.2"]} +{"pcdb_id": 16999, "brand_name": "Viessmann", "model_name": "Vitodens 100-W", "model_qualifier": "WB1C 26kW System Boiler", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 23.7, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["016999", "000033", "0", "2013/Sep/20 08:23", "Viessmann", "Viessmann", "Vitodens 100-W", "WB1C 26kW System Boiler", "", "2012", "2015", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "23.7", "23.7", "", "", "88.5", "79.5", "", "58.0", "", "2", "", "", "102", "1", "2", "87.3", "4.92", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "97.8", "", "", "", "", "96.0"]} +{"pcdb_id": 17000, "brand_name": "Viessmann", "model_name": "Vitodens 100-W", "model_qualifier": "WB1C 26kW Combi Boiler", "winter_efficiency_pct": 89.5, "summer_efficiency_pct": 80.9, "comparative_hot_water_efficiency_pct": 56.9, "output_kw_max": 23.7, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017000", "000033", "0", "2013/Sep/20 08:25", "Viessmann", "Viessmann", "Vitodens 100-W", "WB1C 26kW Combi Boiler", "", "2012", "2015", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "23.7", "23.7", "", "", "89.5", "80.9", "", "56.9", "", "2", "1", "", "104", "1", "2", "87.3", "4.92", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.3", "100.0", "", "", "", "", "98.2"]} +{"pcdb_id": 17001, "brand_name": "Viessmann", "model_name": "Vitodens 100-W", "model_qualifier": "WB1C 26kW Combi Boiler", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 88.2, "comparative_hot_water_efficiency_pct": 70.3, "output_kw_max": 23.7, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.0065, "loss_factor_f1_kwh_per_day": 1.33028, "loss_factor_f2_kwh_per_day": 1.30152, "rejected_factor_f3_per_litre": 5e-05, "raw": ["017001", "000033", "0", "2020/Apr/09 16:23", "Viessmann", "Viessmann", "Vitodens 100-W", "WB1C 26kW Combi Boiler", "", "2012", "2015", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "23.7", "23.7", "", "", "88.5", "88.2", "", "70.3", "", "2", "", "", "104", "1", "2", "87.3", "4.92", "0", "", "", "", "0", "", "", "", "", "2", "7.489", "0.174", "0.0065", "1.33028", "13.26", "0.199", "0.0016", "1.30152", "0.00005", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "97.8", "", "", "", "", "96.0"]} +{"pcdb_id": 17002, "brand_name": "Viessmann", "model_name": "Vitodens 100-W", "model_qualifier": "WB1C 30kW System Boiler", "winter_efficiency_pct": 89.3, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 58.7, "output_kw_max": 27.3, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017002", "000033", "0", "2013/Sep/20 08:21", "Viessmann", "Viessmann", "Vitodens 100-W", "WB1C 30kW System Boiler", "", "2012", "2015", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "27.3", "27.3", "", "", "89.3", "80.3", "", "58.7", "", "2", "1", "", "102", "1", "2", "93.6", "4.76", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.3", "99.7", "", "", "", "", "97.9"]} +{"pcdb_id": 17003, "brand_name": "Viessmann", "model_name": "Vitodens 100-W", "model_qualifier": "WB1C 30kW System Boiler", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 27.3, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017003", "000033", "0", "2015/Nov/02 11:33", "Viessmann", "Viessmann", "Vitodens 100-W", "WB1C 30kW System Boiler", "", "2012", "2015", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "27.3", "27.3", "", "", "88.3", "79.3", "", "57.9", "", "2", "", "", "102", "1", "2", "93.6", "4.76", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "97.5", "", "", "", "", "95.7"]} +{"pcdb_id": 17004, "brand_name": "Viessmann", "model_name": "Vitodens 100-W", "model_qualifier": "WB1C 35kW Combi Boiler", "winter_efficiency_pct": 89.7, "summer_efficiency_pct": 81.1, "comparative_hot_water_efficiency_pct": 57.0, "output_kw_max": 31.9, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017004", "000033", "0", "2013/Sep/20 08:18", "Viessmann", "Viessmann", "Vitodens 100-W", "WB1C 35kW Combi Boiler", "", "2012", "2015", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "31.9", "31.9", "", "", "89.7", "81.1", "", "57.0", "", "2", "1", "", "104", "1", "2", "143", "4.76", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.2", "100.7", "", "", "", "", "98.7"]} +{"pcdb_id": 17005, "brand_name": "Viessmann", "model_name": "Vitodens 100-W", "model_qualifier": "WB1C 35kW Combi", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 88.2, "comparative_hot_water_efficiency_pct": 72.5, "output_kw_max": 31.9, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.0025, "loss_factor_f1_kwh_per_day": 1.13548, "loss_factor_f2_kwh_per_day": 1.10995, "rejected_factor_f3_per_litre": 2e-05, "raw": ["017005", "000033", "0", "2020/Apr/09 16:23", "Viessmann", "Viessmann", "Vitodens 100-W", "WB1C 35kW Combi", "", "2012", "2015", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "31.9", "31.9", "", "", "88.7", "88.2", "", "72.5", "", "2", "", "", "104", "1", "2", "143", "4.76", "0", "", "", "0", "0", "", "", "", "", "2", "7.265", "0.194", "0.0025", "1.13548", "13.113", "0.221", "0.0006", "1.10995", "0.00002", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.2", "98.5", "", "", "", "", "96.5"]} +{"pcdb_id": 17006, "brand_name": "Viessmann", "model_name": "Vitodens 100-W WB1B", "model_qualifier": "35kW Regular Boiler Open Vent", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 31.9, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017006", "000033", "0", "2017/Feb/20 10:57", "Viessmann", "Viessmann", "Vitodens 100-W WB1B", "35kW Regular Boiler Open Vent", "", "2012", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "31.9", "31.9", "", "", "89.0", "80.0", "", "58.5", "", "2", "1", "", "102", "1", "2", "143", "4.76", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "", "", "", "", "89.8", "99.1", "", "", "", "", "97.3"]} +{"pcdb_id": 17007, "brand_name": "Viessmann", "model_name": "Vitodens 100W WB1B", "model_qualifier": "35kW Regular Boiler Open Vent", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 31.9, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017007", "000033", "0", "2017/Feb/20 10:57", "Viessmann", "Viessmann", "Vitodens 100W WB1B", "35kW Regular Boiler Open Vent", "", "2012", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "31.9", "31.9", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "143", "4.76", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "", "", "", "", "87.8", "96.9", "", "", "", "", "95.2"]} +{"pcdb_id": 17008, "brand_name": "Viessmann", "model_name": "Vitodens 111-W", "model_qualifier": "B1LA 26kW", "winter_efficiency_pct": 89.5, "summer_efficiency_pct": 82.2, "comparative_hot_water_efficiency_pct": 44.5, "output_kw_max": 23.7, "final_year_of_manufacture": 2016, "subsidiary_type": 0, "store_type": 1, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017008", "000033", "0", "2024/Jan/31 10:17", "Viessmann", "Viessmann", "Vitodens 111-W", "B1LA 26kW", "", "2012", "2016", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "23.7", "23.7", "", "", "89.5", "82.2", "", "44.5", "", "2", "1", "0", "106", "1", "2", "160", "2.11", "1", "", "", "46", "0", "25", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.3", "100.0", "", "", "", "", "98.2"]} +{"pcdb_id": 17009, "brand_name": "Viessmann", "model_name": "Vitodens 111-W", "model_qualifier": "B1LA 26kW", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 81.2, "comparative_hot_water_efficiency_pct": 44.0, "output_kw_max": 23.7, "final_year_of_manufacture": 2016, "subsidiary_type": 0, "store_type": 1, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017009", "000033", "0", "2024/Jan/31 10:17", "Viessmann", "Viessmann", "Vitodens 111-W", "B1LA 26kW", "", "2012", "2016", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "23.7", "23.7", "", "", "88.5", "81.2", "", "44.0", "", "2", "", "", "106", "1", "2", "160", "2.11", "1", "", "", "46", "0", "25", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "97.8", "", "", "", "", "96.0"]} +{"pcdb_id": 17010, "brand_name": "Viessmann", "model_name": "Vitodens 111-W", "model_qualifier": "B1LA 35kW", "winter_efficiency_pct": 89.7, "summer_efficiency_pct": 82.4, "comparative_hot_water_efficiency_pct": 44.7, "output_kw_max": 31.9, "final_year_of_manufacture": 2016, "subsidiary_type": 0, "store_type": 1, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017010", "000033", "0", "2024/Jan/31 10:17", "Viessmann", "Viessmann", "Vitodens 111-W", "B1LA 35kW", "", "2012", "2016", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "31.9", "31.9", "", "", "89.7", "82.4", "", "44.7", "", "2", "1", "", "106", "1", "2", "160", "2.11", "1", "", "", "46", "0", "25", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.2", "100.7", "", "", "", "", "98.7"]} +{"pcdb_id": 17011, "brand_name": "Viessmann", "model_name": "Vitodens 111-W", "model_qualifier": "B1LA 35kW", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 81.4, "comparative_hot_water_efficiency_pct": 44.1, "output_kw_max": 31.9, "final_year_of_manufacture": 2016, "subsidiary_type": 0, "store_type": 1, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017011", "000033", "0", "2024/Jan/31 10:17", "Viessmann", "Viessmann", "Vitodens 111-W", "B1LA 35kW", "", "2012", "2016", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "31.9", "31.9", "", "", "88.7", "81.4", "", "44.1", "", "2", "", "", "106", "1", "2", "160", "2.11", "1", "", "", "46", "0", "25", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.2", "98.5", "", "", "", "", "96.5"]} +{"pcdb_id": 17012, "brand_name": "Viessmann", "model_name": "Vitodens 100-W", "model_qualifier": "WB1C 30kW Combi Boiler", "winter_efficiency_pct": 89.3, "summer_efficiency_pct": 80.7, "comparative_hot_water_efficiency_pct": 56.8, "output_kw_max": 27.3, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017012", "000033", "0", "2013/Sep/20 08:22", "Viessmann", "Viessmann", "Vitodens 100-W", "WB1C 30kW Combi Boiler", "", "2012", "2015", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "27.3", "27.3", "", "", "89.3", "80.7", "", "56.8", "", "2", "1", "", "104", "1", "2", "93.6", "4.76", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.3", "99.7", "", "", "", "", "97.9"]} +{"pcdb_id": 17013, "brand_name": "Viessmann", "model_name": "Vitodens 100-W", "model_qualifier": "WB1C 30kW Combi Boiler", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 87.8, "comparative_hot_water_efficiency_pct": 72.0, "output_kw_max": 27.3, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.0393, "loss_factor_f1_kwh_per_day": 0.96995, "loss_factor_f2_kwh_per_day": 0.91208, "rejected_factor_f3_per_litre": 0.00038, "raw": ["017013", "000033", "0", "2020/Apr/09 16:22", "Viessmann", "Viessmann", "Vitodens 100-W", "WB1C 30kW Combi Boiler", "", "2012", "2015", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "27.3", "27.3", "", "", "88.3", "87.8", "", "72.0", "", "2", "", "", "104", "1", "2", "93.6", "4.76", "0", "", "", "0", "0", "", "", "", "", "2", "7.314", "0.187", "0.0393", "0.96995", "13.051", "0.212", "0.001", "0.91208", "0.00038", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "97.5", "", "", "", "", "95.7"]} +{"pcdb_id": 17014, "brand_name": "Viessmann", "model_name": "Vitodens 100-W", "model_qualifier": "BPJA 25kW P29", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 56.2, "output_kw_max": 22.8, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017014", "000033", "0", "2013/Sep/20 08:27", "Viessmann", "Viessmann", "Vitodens 100-W", "BPJA 25kW P29", "", "2012", "2015", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "22.8", "22.8", "", "", "88.5", "79.9", "", "56.2", "", "2", "", "", "104", "1", "2", "92.0", "4.76", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.5", "97.9", "", "", "", "", "96.1"]} +{"pcdb_id": 17015, "brand_name": "Viessmann", "model_name": "Vitodens 100-W", "model_qualifier": "BPJA 25 kW P29", "winter_efficiency_pct": 89.5, "summer_efficiency_pct": 80.9, "comparative_hot_water_efficiency_pct": 56.9, "output_kw_max": 22.8, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017015", "000033", "0", "2013/Sep/20 08:27", "Viessmann", "Viessmann", "Vitodens 100-W", "BPJA 25 kW P29", "", "2012", "2015", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "22.8", "22.8", "", "", "89.5", "80.9", "", "56.9", "", "2", "1", "", "104", "1", "2", "92.0", "4.76", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.4", "100.1", "", "", "", "", "98.3"]} +{"pcdb_id": 17016, "brand_name": "Viessmann", "model_name": "Vitodens 100-W", "model_qualifier": "BPJA 21kW P25", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 56.2, "output_kw_max": 19.1, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017016", "000033", "0", "2013/Sep/20 08:28", "Viessmann", "Viessmann", "Vitodens 100-W", "BPJA 21kW P25", "", "2012", "2015", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "19.1", "19.1", "", "", "88.5", "79.9", "", "56.2", "", "2", "", "", "104", "1", "2", "85.0", "4.76", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.2", "97.9", "", "", "", "", "96.1"]} +{"pcdb_id": 17017, "brand_name": "Viessmann", "model_name": "Vitodens 100-W", "model_qualifier": "BPJA 21kW P25", "winter_efficiency_pct": 89.5, "summer_efficiency_pct": 80.9, "comparative_hot_water_efficiency_pct": 56.9, "output_kw_max": 19.1, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017017", "000033", "0", "2013/Sep/20 08:30", "Viessmann", "Viessmann", "Vitodens 100-W", "BPJA 21kW P25", "", "2012", "2015", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "19.1", "19.1", "", "", "89.5", "80.9", "", "56.9", "", "2", "1", "", "104", "1", "2", "85.0", "4.76", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.2", "100.1", "", "", "", "", "98.2"]} +{"pcdb_id": 17018, "brand_name": "Rhino Savannah", "model_name": "RH15/20 Heatpac", "model_qualifier": "", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 81.4, "comparative_hot_water_efficiency_pct": 59.5, "output_kw_max": 20.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017018", "000223", "0", "2013/Aug/29 14:35", "Firebird Boilers", "Rhino Savannah", "RH15/20 Heatpac", "", "", "2012", "current", "4", "1", "2", "1", "0", "", "", "2", "1", "1", "15", "20", "", "", "89.2", "81.4", "", "59.5", "", "2", "", "", "201", "1", "1", "38", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "93.0", "97.0", "", "", "", "", "96.2"]} +{"pcdb_id": 17019, "brand_name": "Rhino Savannah", "model_name": "RB 15/20 Boilerhouse", "model_qualifier": "", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 81.4, "comparative_hot_water_efficiency_pct": 59.5, "output_kw_max": 20.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017019", "000223", "0", "2013/Aug/29 14:35", "Firebird Boilers", "Rhino Savannah", "RB 15/20 Boilerhouse", "", "", "2012", "current", "4", "1", "1", "1", "0", "", "", "2", "2", "1", "15", "20", "", "", "89.2", "81.4", "", "59.5", "", "2", "", "", "201", "1", "1", "38", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "93.0", "97.0", "", "", "", "", "96.2"]} +{"pcdb_id": 17020, "brand_name": "Rhino Savannah", "model_name": "R15/20 Kitchen", "model_qualifier": "", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 81.4, "comparative_hot_water_efficiency_pct": 59.5, "output_kw_max": 20.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017020", "000223", "0", "2013/Aug/29 14:35", "Firebird Boilers", "Rhino Savannah", "R15/20 Kitchen", "", "", "2012", "current", "4", "1", "1", "1", "0", "", "", "2", "2", "1", "15", "20", "", "", "89.2", "81.4", "", "59.5", "", "2", "", "", "201", "1", "1", "38", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "93.0", "97.0", "", "", "", "", "96.2"]} +{"pcdb_id": 17021, "brand_name": "Rhino Savannah", "model_name": "RC15/20 Combi Boiler", "model_qualifier": "", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 81.8, "comparative_hot_water_efficiency_pct": 57.5, "output_kw_max": 20.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017021", "000223", "0", "2013/Aug/29 14:35", "Firebird Boilers", "Rhino Savannah", "RC15/20 Combi Boiler", "", "", "2012", "current", "4", "1", "1", "2", "0", "", "", "2", "2", "1", "15", "20", "", "", "89.2", "81.8", "", "57.5", "", "2", "", "", "202", "1", "1", "38", "0", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "93.0", "97.0", "", "", "", "", "96.2"]} +{"pcdb_id": 17022, "brand_name": "Rhino Savannah", "model_name": "RP15/20 Combipac", "model_qualifier": "", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 81.8, "comparative_hot_water_efficiency_pct": 57.5, "output_kw_max": 20.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017022", "000223", "0", "2013/Aug/29 14:35", "Firebird Boilers", "Rhino Savannah", "RP15/20 Combipac", "", "", "2012", "current", "4", "1", "2", "2", "0", "", "", "2", "1", "1", "15", "20", "", "", "89.2", "81.8", "", "57.5", "", "2", "", "", "202", "1", "1", "38", "0", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "93.0", "97.0", "", "", "", "", "96.2"]} +{"pcdb_id": 17023, "brand_name": "Rhino Savannah", "model_name": "RH20/26 Heatpac", "model_qualifier": "", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 81.4, "comparative_hot_water_efficiency_pct": 59.5, "output_kw_max": 26.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017023", "000223", "0", "2013/Aug/29 14:35", "Firebird Boilers", "Rhino Savannah", "RH20/26 Heatpac", "", "", "2012", "current", "4", "1", "2", "1", "0", "", "", "2", "1", "1", "20", "26", "", "", "89.2", "81.4", "", "59.5", "", "2", "", "", "201", "1", "1", "38", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "93.1", "96.9", "", "", "", "", "96.2"]} +{"pcdb_id": 17024, "brand_name": "Rhino Savannah", "model_name": "RB20/26 Boilerhouse", "model_qualifier": "", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 81.4, "comparative_hot_water_efficiency_pct": 59.5, "output_kw_max": 26.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017024", "000223", "0", "2013/Aug/29 14:35", "Firebird Boilers", "Rhino Savannah", "RB20/26 Boilerhouse", "", "", "2012", "current", "4", "1", "1", "1", "0", "", "", "2", "2", "1", "20", "26", "", "", "89.2", "81.4", "", "59.5", "", "2", "", "", "201", "1", "1", "38", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "93.1", "96.9", "", "", "", "", "96.2"]} +{"pcdb_id": 17025, "brand_name": "Rhino Savannah", "model_name": "R20/26 Kitchen", "model_qualifier": "", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 81.4, "comparative_hot_water_efficiency_pct": 59.5, "output_kw_max": 26.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017025", "000223", "0", "2013/Aug/29 14:35", "Firebird Boilers", "Rhino Savannah", "R20/26 Kitchen", "", "", "2012", "current", "4", "1", "1", "1", "0", "", "", "2", "2", "1", "20", "26", "", "", "89.2", "81.4", "", "59.5", "", "2", "", "", "201", "1", "1", "38", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "93.1", "96.9", "", "", "", "", "96.2"]} +{"pcdb_id": 17026, "brand_name": "Rhino Savannah", "model_name": "RC20/26 Combi Boiler", "model_qualifier": "", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 81.8, "comparative_hot_water_efficiency_pct": 57.5, "output_kw_max": 26.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017026", "000223", "0", "2013/Aug/29 14:35", "Firebird Boilers", "Rhino Savannah", "RC20/26 Combi Boiler", "", "", "2012", "current", "4", "1", "1", "2", "0", "", "", "2", "2", "1", "20", "26", "", "", "89.2", "81.8", "", "57.5", "", "2", "", "", "202", "1", "1", "38", "0", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "93.1", "96.9", "", "", "", "", "96.2"]} +{"pcdb_id": 17027, "brand_name": "Rhino Savannah", "model_name": "RP20/26 Combipac", "model_qualifier": "", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 81.8, "comparative_hot_water_efficiency_pct": 57.5, "output_kw_max": 26.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017027", "000223", "0", "2013/Aug/29 14:34", "Firebird Boilers", "Rhino Savannah", "RP20/26 Combipac", "", "", "2012", "current", "4", "1", "2", "2", "0", "", "", "2", "1", "1", "20", "26", "", "", "89.2", "81.8", "", "57.5", "", "2", "", "", "202", "1", "1", "38", "0", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "93.1", "96.9", "", "", "", "", "96.2"]} +{"pcdb_id": 17028, "brand_name": "Rhino Savannah", "model_name": "RH26/35 Heatpac", "model_qualifier": "", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 80.4, "comparative_hot_water_efficiency_pct": 58.7, "output_kw_max": 35.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017028", "000223", "0", "2013/Aug/29 14:34", "Firebird Boilers", "Rhino Savannah", "RH26/35 Heatpac", "", "", "2012", "current", "4", "1", "2", "1", "0", "", "", "2", "1", "1", "26", "35", "", "", "88.2", "80.4", "", "58.7", "", "2", "", "", "201", "1", "1", "38", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "92.2", "94.6", "", "", "", "", "94.2"]} +{"pcdb_id": 17029, "brand_name": "Rhino Savannah", "model_name": "RB26/35 Boilerhouse", "model_qualifier": "", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 80.4, "comparative_hot_water_efficiency_pct": 58.7, "output_kw_max": 35.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017029", "000223", "0", "2013/Aug/29 14:34", "Firebird Boilers", "Rhino Savannah", "RB26/35 Boilerhouse", "", "", "2012", "current", "4", "1", "1", "1", "0", "", "", "2", "2", "1", "26", "35", "", "", "88.2", "80.4", "", "58.7", "", "2", "", "", "201", "1", "1", "38", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "92.2", "94.6", "", "", "", "", "94.2"]} +{"pcdb_id": 17030, "brand_name": "Rhino Savannah", "model_name": "R26/35 Kitchen", "model_qualifier": "", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 80.4, "comparative_hot_water_efficiency_pct": 58.7, "output_kw_max": 35.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017030", "000223", "0", "2013/Aug/29 14:34", "Firebird Boilers", "Rhino Savannah", "R26/35 Kitchen", "", "", "2012", "current", "4", "1", "1", "1", "0", "", "", "2", "2", "1", "26", "35", "", "", "88.2", "80.4", "", "58.7", "", "2", "", "", "201", "1", "1", "38", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "92.2", "94.6", "", "", "", "", "94.2"]} +{"pcdb_id": 17031, "brand_name": "Rhino Savannah", "model_name": "RC26/35 Combi Boiler", "model_qualifier": "", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 56.8, "output_kw_max": 35.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017031", "000223", "0", "2013/Aug/29 14:34", "Firebird Boilers", "Rhino Savannah", "RC26/35 Combi Boiler", "", "", "2012", "current", "4", "1", "1", "2", "0", "", "", "2", "2", "1", "26", "35", "", "", "88.2", "80.8", "", "56.8", "", "2", "", "", "202", "1", "1", "38", "0", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "92.2", "94.6", "", "", "", "", "94.2"]} +{"pcdb_id": 17032, "brand_name": "Rhino Savannah", "model_name": "RP26/35 Combipac", "model_qualifier": "", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 56.8, "output_kw_max": 35.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017032", "000223", "0", "2013/Aug/29 14:34", "Firebird Boilers", "Rhino Savannah", "RP26/35 Combipac", "", "", "2012", "current", "4", "1", "2", "2", "0", "", "", "2", "1", "1", "26", "35", "", "", "88.2", "80.8", "", "56.8", "", "2", "", "", "202", "1", "1", "38", "0", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "92.2", "94.6", "", "", "", "", "94.2"]} +{"pcdb_id": 17033, "brand_name": "Ideal", "model_name": "VOGUE", "model_qualifier": "s32", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 32.0, "final_year_of_manufacture": 2017, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017033", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "VOGUE", "s32", "41-750-53", "2012", "2017", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "32", "32", "", "", "88.7", "79.7", "", "58.2", "", "2", "", "", "102", "1", "2", "117", "1", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "89.8", "97.8", "", "", "", "", "96.3"]} +{"pcdb_id": 17034, "brand_name": "Ideal", "model_name": "VOGUE", "model_qualifier": "s26", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 26.0, "final_year_of_manufacture": 2017, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017034", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "VOGUE", "s26", "41-750-54", "2012", "2017", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "26", "26", "", "", "88.7", "79.7", "", "58.2", "", "2", "", "", "102", "1", "2", "102", "1", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "89.7", "97.8", "", "", "", "", "96.2"]} +{"pcdb_id": 17035, "brand_name": "Ideal", "model_name": "VOGUE", "model_qualifier": "s18", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 18.0, "final_year_of_manufacture": 2017, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017035", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "VOGUE", "s18", "41-750-55", "2012", "2017", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18", "18", "", "", "88.7", "79.7", "", "58.2", "", "2", "", "", "102", "1", "2", "92", "1", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "89.8", "97.8", "", "", "", "", "96.3"]} +{"pcdb_id": 17036, "brand_name": "Ideal", "model_name": "VOGUE", "model_qualifier": "s15", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 15.0, "final_year_of_manufacture": 2017, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017036", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "VOGUE", "s15", "41-750-56", "2012", "2017", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "15", "15", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "83", "1", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "89.6", "97.0", "", "", "", "", "95.6"]} +{"pcdb_id": 17037, "brand_name": "Ideal", "model_name": "VOGUE", "model_qualifier": "c26", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 76.4, "output_kw_max": 18.0, "final_year_of_manufacture": 2017, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0286, "loss_factor_f1_kwh_per_day": 0.66626, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017037", "000008", "0", "2018/Oct/28 12:00", "Ideal Boilers", "Ideal", "VOGUE", "c26", "47-348-99", "2012", "2017", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "18", "18", "", "", "88.6", "87.3", "", "76.4", "", "2", "", "", "104", "1", "2", "108", "1", "0", "", "", "", "0", "", "", "", "", "1", "6.8963", "0.2267", "0.0286", "0.66626", "", "", "", "", "", "1", "1", "", "0035", "", "", "", "", "", "", "", "", "89.7", "97.7", "", "", "", "", "96.2"]} +{"pcdb_id": 17038, "brand_name": "Ideal", "model_name": "VOGUE", "model_qualifier": "c32", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 76.7, "output_kw_max": 26.0, "final_year_of_manufacture": 2017, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0075, "loss_factor_f1_kwh_per_day": 0.76726, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017038", "000008", "0", "2018/Oct/28 12:00", "Ideal Boilers", "Ideal", "VOGUE", "c32", "47-348-98", "2012", "2017", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "26", "26", "", "", "88.7", "87.3", "", "76.7", "", "2", "", "", "104", "1", "2", "137", "1", "0", "", "", "", "0", "", "", "", "", "1", "6.8683", "0.1702", "0.0075", "0.76726", "", "", "", "", "", "1", "1", "", "0035", "", "", "", "", "", "", "", "", "89.9", "97.8", "", "", "", "", "96.3"]} +{"pcdb_id": 17039, "brand_name": "Ideal", "model_name": "VOGUE", "model_qualifier": "c40", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 76.8, "output_kw_max": 32.0, "final_year_of_manufacture": 2017, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0292, "loss_factor_f1_kwh_per_day": 0.62576, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017039", "000008", "0", "2018/Oct/28 12:00", "Ideal Boilers", "Ideal", "VOGUE", "c40", "47-348-97", "2012", "2017", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "32", "32", "", "", "88.6", "87.3", "", "76.8", "", "2", "", "", "104", "1", "2", "133", "1", "0", "", "", "", "0", "", "", "", "", "1", "6.8578", "0.1994", "0.0292", "0.62576", "", "", "", "", "", "1", "1", "", "0035", "", "", "", "", "", "", "", "", "89.7", "97.5", "", "", "", "", "96.0"]} +{"pcdb_id": 17040, "brand_name": "Keston", "model_name": "Combi", "model_qualifier": "30", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 69.8, "output_kw_max": 24.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0099, "loss_factor_f1_kwh_per_day": 1.41408, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017040", "000022", "0", "2013/Feb/27 12:37", "Keston Boilers", "Keston", "Combi", "30", "47-930-04", "2013", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "88.4", "87.3", "", "69.8", "", "2", "", "", "104", "1", "2", "1", "152", "0", "", "", "", "0", "", "", "", "", "1", "7.548", "0.1749", "0.0099", "1.41408", "", "", "", "", "", "1", "1", "", "0025", "", "", "", "", "", "", "", "", "90.0", "96.9", "", "", "", "", "95.6"]} +{"pcdb_id": 17041, "brand_name": "Keston", "model_name": "System", "model_qualifier": "30", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 30.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017041", "000022", "0", "2013/Feb/27 12:38", "Keston Boilers", "Keston", "System", "30", "41-750-32", "2013", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "30.3", "30.3", "", "", "88.9", "79.9", "", "58.3", "", "2", "", "", "102", "1", "2", "1", "152", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "89.8", "98.2", "", "", "", "", "96.6"]} +{"pcdb_id": 17042, "brand_name": "Keston", "model_name": "Combi", "model_qualifier": "35", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 71.0, "output_kw_max": 24.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0087, "loss_factor_f1_kwh_per_day": 1.2937, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017042", "000022", "0", "2013/Feb/27 12:38", "Keston Boilers", "Keston", "Combi", "35", "47-930-05", "2013", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "88.3", "87.3", "", "71.0", "", "2", "", "", "104", "1", "2", "1", "177", "0", "", "", "", "0", "", "", "", "", "1", "7.4216", "0.171", "0.0087", "1.2937", "", "", "", "", "", "1", "1", "", "0025", "", "", "", "", "", "", "", "", "89.8", "96.9", "", "", "", "", "95.5"]} +{"pcdb_id": 17043, "brand_name": "Ideal", "model_name": "LOGIC COMBI", "model_qualifier": "ES24", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 76.9, "output_kw_max": 24.2, "final_year_of_manufacture": 2016, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0257, "loss_factor_f1_kwh_per_day": 0.63741, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017043", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "LOGIC COMBI", "ES24", "47-349-01", "2013", "2016", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "88.4", "87.3", "", "76.9", "", "2", "", "", "104", "1", "2", "146", "1", "0", "", "", "", "0", "", "", "", "", "1", "6.8467", "0.1294", "0.0257", "0.63741", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "", "", "", "", "89.8", "96.9", "", "", "", "", "95.6"]} +{"pcdb_id": 17044, "brand_name": "Ideal", "model_name": "LOGIC COMBI", "model_qualifier": "ES30", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 76.5, "output_kw_max": 24.2, "final_year_of_manufacture": 2016, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0177, "loss_factor_f1_kwh_per_day": 0.72229, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017044", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "LOGIC COMBI", "ES30", "47-349-02", "2012", "2016", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "88.4", "87.3", "", "76.5", "", "2", "", "", "104", "1", "2", "152", "1", "0", "", "", "", "0", "", "", "", "", "1", "6.8814", "0.113", "0.0177", "0.72229", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "", "", "", "", "90.0", "96.9", "", "", "", "", "95.6"]} +{"pcdb_id": 17045, "brand_name": "Ideal", "model_name": "LOGIC COMBI", "model_qualifier": "ES35", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 76.0, "output_kw_max": 24.2, "final_year_of_manufacture": 2016, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0156, "loss_factor_f1_kwh_per_day": 0.77685, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017045", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "LOGIC COMBI", "ES35", "47-349-03", "2013", "2016", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "88.3", "87.3", "", "76.0", "", "2", "", "", "104", "1", "2", "177", "1", "0", "", "", "", "0", "", "", "", "", "1", "6.9297", "0.1257", "0.0156", "0.77685", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "", "", "", "", "89.8", "96.9", "", "", "", "", "95.5"]} +{"pcdb_id": 17046, "brand_name": "Alpha", "model_name": "InTec 50 CS", "model_qualifier": "", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 81.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 28.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017046", "000001", "0", "2024/Jan/31 10:17", "Alpha Therm", "Alpha", "InTec 50 CS", "", "", "2012", "current", "2", "1", "1", "2", "0", "", "", "2", "2", "2", "28", "28", "", "", "89.0", "81.7", "", "58.2", "", "2", "1", "", "106", "1", "2", "165", "4.4", "2", "", "", "54", "0", "50", "2", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.1", "98.8", "", "", "", "", "97.2"]} +{"pcdb_id": 17047, "brand_name": "Alpha", "model_name": "InTec 50 CS", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 86.7, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 28.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0045, "loss_factor_f1_kwh_per_day": 2.91007, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017047", "000001", "0", "2019/Dec/16 13:35", "Alpha Therm", "Alpha", "InTec 50 CS", "", "", "2012", "current", "1", "1", "1", "2", "0", "", "", "2", "2", "2", "28", "28", "", "", "88.0", "86.7", "", "57.7", "", "2", "", "", "106", "1", "2", "165", "4.4", "2", "", "", "54", "0", "50", "2", "", "", "1", "9.123", "0.205", "0.0045", "2.91007", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.1", "96.7", "", "", "", "", "95.1"]} +{"pcdb_id": 17048, "brand_name": "Johnson & Starley", "model_name": "QuanTec", "model_qualifier": "16R", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 16.27, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017048", "000239", "0", "2015/Sep/21 14:23", "Johnson & Starley", "Johnson & Starley", "QuanTec", "16R", "", "2013", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "16.27", "16.27", "", "", "89.0", "80.0", "", "58.4", "", "2", "", "", "102", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "", "", "", "", "88.7", "98.9", "", "", "", "", "97.0"]} +{"pcdb_id": 17049, "brand_name": "Johnson & Starley", "model_name": "QuanTec", "model_qualifier": "24R", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 23.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017049", "000239", "0", "2015/Sep/21 14:23", "Johnson & Starley", "Johnson & Starley", "QuanTec", "24R", "", "2013", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "23.4", "23.4", "", "", "88.9", "79.9", "", "58.4", "", "2", "", "", "102", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "", "", "", "", "87.9", "99.1", "", "", "", "", "97.0"]} +{"pcdb_id": 17050, "brand_name": "Johnson & Starley", "model_name": "QuanTec", "model_qualifier": "24S", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 23.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017050", "000239", "0", "2015/Sep/21 14:23", "Johnson & Starley", "Johnson & Starley", "QuanTec", "24S", "", "2013", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "23.4", "23.4", "", "", "88.9", "79.9", "", "58.4", "", "2", "", "", "102", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "", "", "", "", "87.9", "99.1", "", "", "", "", "97.0"]} +{"pcdb_id": 17051, "brand_name": "Johnson & Starley", "model_name": "QuanTec", "model_qualifier": "24C", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 86.9, "comparative_hot_water_efficiency_pct": 76.5, "output_kw_max": 16.27, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0145, "loss_factor_f1_kwh_per_day": 0.71547, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017051", "000239", "0", "2015/Sep/21 14:23", "Johnson & Starley", "Johnson & Starley", "QuanTec", "24C", "CE595890", "2013", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "16.27", "16.27", "", "", "89.0", "86.9", "", "76.5", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "", "0", "", "", "", "", "1", "6.8876", "0.1134", "0.0145", "0.71547", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "", "", "", "", "88.7", "98.9", "", "", "", "", "97.0"]} +{"pcdb_id": 17052, "brand_name": "Johnson & Starley", "model_name": "QuanTec", "model_qualifier": "30C", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 86.7, "comparative_hot_water_efficiency_pct": 70.0, "output_kw_max": 23.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0103, "loss_factor_f1_kwh_per_day": 1.33381, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017052", "000239", "0", "2015/Sep/21 14:23", "Johnson & Starley", "Johnson & Starley", "QuanTec", "30C", "", "2013", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "23.4", "23.4", "", "", "88.9", "86.7", "", "70.0", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "", "0", "", "", "", "", "1", "7.526", "0.1115", "0.0103", "1.33381", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "", "", "", "", "87.9", "99.1", "", "", "", "", "97.0"]} +{"pcdb_id": 17053, "brand_name": "Keston", "model_name": "Heat 55", "model_qualifier": "", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 52.1, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017053", "000022", "0", "2013/May/24 12:33", "Keston Boilers", "Keston", "Heat 55", "", "41-930-41", "2013", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "52.1", "52.1", "", "", "88.9", "79.9", "", "58.4", "", "2", "", "", "102", "1", "2", "262", "8.91", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "89.7", "98.5", "", "", "", "", "96.8"]} +{"pcdb_id": 17054, "brand_name": "Keston", "model_name": "Heat 45", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 42.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017054", "000022", "0", "2013/May/24 12:33", "Keston Boilers", "Keston", "Heat 45", "", "41-930-40", "2013", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "42.6", "42.6", "", "", "88.5", "79.5", "", "58.0", "", "2", "", "", "102", "1", "2", "202", "8.91", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "88.7", "97.7", "", "", "", "", "96.0"]} +{"pcdb_id": 17055, "brand_name": "Glow-worm", "model_name": "Ultimate 30c", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 86.5, "comparative_hot_water_efficiency_pct": 73.9, "output_kw_max": 24.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0, "loss_factor_f1_kwh_per_day": 0.99665, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017055", "000207", "0", "2013/Feb/28 09:24", "Vaillant Industrial UK", "Glow-worm", "Ultimate 30c", "", "GC No 47-019-20", "2013", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "88.3", "86.5", "", "73.9", "", "2", "", "", "104", "1", "2", "35", "3.5", "0", "", "", "", "0", "", "", "", "", "1", "7.125", "0.095", "0.0", "0.99665", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.5", "97.7", "", "", "", "", "95.7"]} +{"pcdb_id": 17056, "brand_name": "Glow-worm", "model_name": "Ultimate 30c", "model_qualifier": "", "winter_efficiency_pct": 89.3, "summer_efficiency_pct": 80.7, "comparative_hot_water_efficiency_pct": 56.7, "output_kw_max": 24.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017056", "000207", "0", "2013/Feb/28 11:27", "Vaillant Industrial UK", "Glow-worm", "Ultimate 30c", "", "", "2013", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "89.3", "80.7", "", "56.7", "", "2", "1", "", "104", "1", "2", "35", "3.5", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.4", "99.8", "", "", "", "", "97.9"]} +{"pcdb_id": 17057, "brand_name": "Ferroli", "model_name": "Modena 32S HE", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 31.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017057", "000097", "0", "2013/Jul/30 12:07", "Ferroli", "Ferroli", "Modena 32S HE", "", "", "2012", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "31.4", "31.4", "", "", "88.6", "79.6", "", "58.1", "", "2", "", "", "102", "1", "2", "100", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.4", "98.1", "", "", "", "", "96.3"]} +{"pcdb_id": 17058, "brand_name": "Glow-worm", "model_name": "Ultimate", "model_qualifier": "24h", "winter_efficiency_pct": 87.7, "summer_efficiency_pct": 78.7, "comparative_hot_water_efficiency_pct": 57.5, "output_kw_max": 24.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017058", "000207", "0", "2013/Feb/28 09:23", "Glow-worm", "Glow-worm", "Ultimate", "24h", "GC 41-019-15", "2006", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24", "24", "", "", "87.7", "78.7", "", "57.5", "", "2", "", "", "102", "1", "2", "60", "6", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.8", "95.7", "", "", "", "", "94.4"]} +{"pcdb_id": 17059, "brand_name": "Grant", "model_name": "Vortex Pro Boilerhouse 36-46", "model_qualifier": "", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 46.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017059", "000048", "0", "2014/Aug/15 12:54", "Grant Engineering (UK)", "Grant", "Vortex Pro Boilerhouse 36-46", "", "", "2012", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "36", "46", "", "", "87.9", "80.1", "", "58.5", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.8", "94.4", "", "", "", "", "93.8"]} +{"pcdb_id": 17060, "brand_name": "Grant", "model_name": "Vortex Pro Boilerhouse 46-58", "model_qualifier": "", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 81.1, "comparative_hot_water_efficiency_pct": 59.2, "output_kw_max": 58.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017060", "000048", "0", "2013/Feb/27 15:44", "Grant Engineering (UK)", "Grant", "Vortex Pro Boilerhouse 46-58", "", "", "2012", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "46", "58", "", "", "88.9", "81.1", "", "59.2", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.5", "96.7", "", "", "", "", "95.7"]} +{"pcdb_id": 17061, "brand_name": "Grant", "model_name": "Vortex Pro Boilerhouse 58-70", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 59.0, "output_kw_max": 70.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017061", "000048", "0", "2013/Feb/27 15:44", "Grant Engineering (UK)", "Grant", "Vortex Pro Boilerhouse 58-70", "", "", "2012", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "58", "70", "", "", "88.6", "80.8", "", "59.0", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.9", "96.2", "", "", "", "", "95.2"]} +{"pcdb_id": 17062, "brand_name": "Grant", "model_name": "Vortex Pro External 58-70", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 59.0, "output_kw_max": 70.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017062", "000048", "0", "2014/Aug/15 12:57", "Grant Engineering (UK)", "Grant", "Vortex Pro External 58-70", "", "", "2012", "current", "4", "1", "2", "1", "0", "", "", "2", "3", "2", "58", "70", "", "", "88.6", "80.8", "", "59.0", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.9", "96.2", "", "", "", "", "95.2"]} +{"pcdb_id": 17063, "brand_name": "Grant", "model_name": "Vortex Pro External 46-58", "model_qualifier": "", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 81.1, "comparative_hot_water_efficiency_pct": 59.2, "output_kw_max": 58.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017063", "000048", "0", "2013/Feb/27 15:44", "Grant Engineering (UK)", "Grant", "Vortex Pro External 46-58", "", "", "2012", "current", "4", "1", "2", "1", "0", "", "", "2", "3", "2", "46", "58", "", "", "88.9", "81.1", "", "59.2", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.5", "96.7", "", "", "", "", "95.7"]} +{"pcdb_id": 17064, "brand_name": "Sime", "model_name": "Meridian HE", "model_qualifier": "30", "winter_efficiency_pct": 89.3, "summer_efficiency_pct": 80.7, "comparative_hot_water_efficiency_pct": 56.7, "output_kw_max": 28.9, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017064", "000213", "0", "2018/Mar/05 14:11", "Fonderie Sime S.p.A.", "Sime", "Meridian HE", "30", "", "2013", "2018", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "28.9", "28.9", "", "", "89.3", "80.7", "", "56.7", "", "2", "1", "", "104", "1", "2", "115", "4.9", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.3", "99.6", "", "", "", "", "97.8"]} +{"pcdb_id": 17066, "brand_name": "Sime", "model_name": "Meridian HE", "model_qualifier": "30", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 56.0, "output_kw_max": 28.9, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017066", "000213", "0", "2018/Mar/05 14:12", "Fonderie Sime S.p.A.", "Sime", "Meridian HE", "30", "47-283-45", "2013", "2018", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28.9", "28.9", "", "", "88.3", "79.7", "", "56.0", "", "2", "", "", "104", "1", "2", "115", "4.9", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "97.4", "", "", "", "", "95.7"]} +{"pcdb_id": 17067, "brand_name": "Sime", "model_name": "Meridian HE", "model_qualifier": "25", "winter_efficiency_pct": 89.6, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 56.9, "output_kw_max": 23.9, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017067", "000213", "0", "2018/Mar/05 14:10", "Fonderie Sime S.p.A.", "Sime", "Meridian HE", "25", "", "2013", "2018", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "23.9", "23.9", "", "", "89.6", "81.0", "", "56.9", "", "2", "1", "", "104", "1", "2", "105", "4.9", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.5", "100.1", "", "", "", "", "98.3"]} +{"pcdb_id": 17068, "brand_name": "Sime", "model_name": "Meridian HE", "model_qualifier": "25", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 56.2, "output_kw_max": 23.9, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017068", "000213", "0", "2018/Mar/05 14:11", "Fonderie Sime S.p.A.", "Sime", "Meridian HE", "25", "47-283-44", "2013", "2018", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "23.9", "23.9", "", "", "88.5", "79.9", "", "56.2", "", "2", "", "", "104", "1", "2", "105", "4.9", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.6", "97.9", "", "", "", "", "96.2"]} +{"pcdb_id": 17069, "brand_name": "Baxi", "model_name": "Avanta 35c Exclusive", "model_qualifier": "", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 29.4, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017069", "000005", "0", "2015/Aug/06 12:12", "Remeha", "Baxi", "Avanta 35c Exclusive", "", "47-288-05", "2012", "2015", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "29.4", "29.4", "", "", "88.9", "79.9", "", "58.4", "", "2", "", "", "102", "1", "2", "115", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.5", "98.8", "", "", "", "", "96.9"]} +{"pcdb_id": 17070, "brand_name": "Baxi", "model_name": "Avanta 39c Exclusive", "model_qualifier": "", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 33.3, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017070", "000005", "0", "2015/Aug/06 12:12", "Remeha", "Baxi", "Avanta 39c Exclusive", "", "47-288-05", "2012", "2015", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "33.3", "33.3", "", "", "89.1", "80.1", "", "58.5", "", "2", "", "", "102", "1", "2", "180", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "99.6", "", "", "", "", "97.4"]} +{"pcdb_id": 17071, "brand_name": "Baxi", "model_name": "Avanta Plus 35c Combi", "model_qualifier": "", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 56.5, "output_kw_max": 29.4, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017071", "000005", "0", "2015/Aug/06 12:13", "Remeha", "Baxi", "Avanta Plus 35c Combi", "", "47-673-03", "2005", "2015", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "29.4", "29.4", "", "", "88.9", "80.3", "", "56.5", "", "2", "", "", "104", "1", "2", "115", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.5", "98.8", "", "", "", "", "96.9"]} +{"pcdb_id": 17072, "brand_name": "Baxi", "model_name": "Avanta Plus 39c Combi", "model_qualifier": "", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 56.6, "output_kw_max": 33.3, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017072", "000005", "0", "2015/Aug/06 12:13", "Remeha", "Baxi", "Avanta Plus 39c Combi", "", "47-673-04", "2005", "2015", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "33.3", "33.3", "", "", "89.1", "80.5", "", "56.6", "", "2", "", "", "104", "1", "2", "180", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "99.6", "", "", "", "", "97.4"]} +{"pcdb_id": 17073, "brand_name": "Baxi", "model_name": "Avanta Plus 28c Combi", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 56.2, "output_kw_max": 21.6, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017073", "000005", "0", "2015/Aug/06 12:14", "Remeha", "Baxi", "Avanta Plus 28c Combi", "", "47-673-02", "2005", "2015", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "21.6", "21.6", "", "", "88.5", "79.9", "", "56.2", "", "2", "", "", "104", "1", "2", "115", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.6", "97.9", "", "", "", "", "96.2"]} +{"pcdb_id": 17074, "brand_name": "Baxi", "model_name": "Avanta 18 h Heat Only", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 17.6, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017074", "000005", "0", "2015/Aug/06 12:14", "Remeha", "Baxi", "Avanta 18 h Heat Only", "", "41-288-06", "2006", "2015", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "17.6", "17.6", "", "", "88.5", "79.5", "", "58.1", "", "2", "", "", "102", "1", "2", "50", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.6", "97.9", "", "", "", "", "96.2"]} +{"pcdb_id": 17075, "brand_name": "Baxi", "model_name": "Avanta 30h Heat Only", "model_qualifier": "", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 29.4, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017075", "000005", "0", "2015/Aug/06 12:15", "Remeha", "Baxi", "Avanta 30h Heat Only", "", "41-288-14", "2009", "2015", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "29.4", "29.4", "", "", "88.2", "79.2", "", "57.9", "", "2", "", "", "102", "1", "2", "115", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.5", "97.1", "", "", "", "", "95.5"]} +{"pcdb_id": 17076, "brand_name": "Baxi", "model_name": "Avanta Plus 30s system", "model_qualifier": "", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 29.4, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017076", "000005", "0", "2015/Aug/06 12:15", "Remeha", "Baxi", "Avanta Plus 30s system", "", "41-288-12", "2008", "2015", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "29.4", "29.4", "", "", "88.2", "79.2", "", "57.9", "", "2", "", "", "102", "1", "2", "150", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.5", "97.1", "", "", "", "", "95.5"]} +{"pcdb_id": 17077, "brand_name": "Baxi", "model_name": "Avanta 28c Exclusive", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 21.6, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017077", "000005", "0", "2015/Aug/06 12:16", "Remeha", "Baxi", "Avanta 28c Exclusive", "", "47-288-03", "2012", "2015", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "21.6", "21.6", "", "", "88.5", "79.5", "", "58.1", "", "2", "", "", "102", "1", "2", "115", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.6", "97.9", "", "", "", "", "96.2"]} +{"pcdb_id": 17078, "brand_name": "Baxi", "model_name": "Avanta 15h Heat Only", "model_qualifier": "", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 15.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017078", "000005", "0", "2015/Aug/06 12:17", "Remeha", "Baxi", "Avanta 15h Heat Only", "", "41-288-13", "2012", "2015", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "15", "15", "", "", "88.2", "79.2", "", "57.8", "", "2", "", "", "102", "1", "2", "50", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.4", "97.0", "", "", "", "", "95.4"]} +{"pcdb_id": 17079, "brand_name": "Baxi", "model_name": "Avanta Plus 24c Combi", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 55.9, "output_kw_max": 20.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017079", "000005", "0", "2015/Aug/06 12:17", "Remeha", "Baxi", "Avanta Plus 24c Combi", "", "47-288-01", "2008", "2015", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "20", "20", "", "", "88.1", "79.5", "", "55.9", "", "2", "", "", "104", "1", "2", "115", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.1", "97.0", "", "", "", "", "95.3"]} +{"pcdb_id": 17080, "brand_name": "Baxi", "model_name": "Avanta Plus 18s system", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 17.6, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017080", "000005", "0", "2015/Aug/06 12:19", "Remeha", "Baxi", "Avanta Plus 18s system", "", "41-288-11", "2008", "2015", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "17.6", "17.6", "", "", "88.1", "79.1", "", "57.8", "", "2", "", "", "102", "1", "2", "115", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.1", "97.0", "", "", "", "", "95.3"]} +{"pcdb_id": 17081, "brand_name": "Baxi", "model_name": "Avanta Plus 24s System", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 21.6, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017081", "000005", "0", "2015/Aug/06 12:20", "Remeha", "Baxi", "Avanta Plus 24s System", "", "41-288-05", "2005", "2015", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "21.6", "21.6", "", "", "88.5", "79.5", "", "58.1", "", "2", "", "", "102", "1", "2", "115", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.6", "97.9", "", "", "", "", "96.2"]} +{"pcdb_id": 17082, "brand_name": "Baxi", "model_name": "Avanta 24h Heat Only", "model_qualifier": "", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 24.7, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017082", "000005", "0", "2015/Aug/06 12:21", "Remeha", "Baxi", "Avanta 24h Heat Only", "", "41-288-10", "2008", "2015", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "24.7", "24.7", "", "", "88.2", "79.2", "", "57.8", "", "2", "", "", "102", "1", "2", "50", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.2", "97.1", "", "", "", "", "95.4"]} +{"pcdb_id": 17083, "brand_name": "Glow-worm", "model_name": "Ultimate", "model_qualifier": "35c", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 86.6, "comparative_hot_water_efficiency_pct": 73.4, "output_kw_max": 30.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0, "loss_factor_f1_kwh_per_day": 1.04455, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017083", "000207", "0", "2013/Apr/22 17:06", "Glow-worm", "Glow-worm", "Ultimate", "35c", "47-019-21", "2013", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "8.5", "30", "", "", "88.2", "86.6", "", "73.4", "", "2", "", "", "104", "1", "2", "41", "3.5", "0", "", "", "", "0", "", "", "", "", "1", "7.17", "0.114", "0.0", "1.04455", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.7", "97.4", "", "", "", "", "95.5"]} +{"pcdb_id": 17084, "brand_name": "Glow-worm", "model_name": "Ultimate", "model_qualifier": "35c", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 80.6, "comparative_hot_water_efficiency_pct": 56.7, "output_kw_max": 30.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017084", "000207", "0", "2013/Apr/22 17:06", "Glow-worm", "Glow-worm", "Ultimate", "35c", "", "2013", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "8.5", "30", "", "", "89.2", "80.6", "", "56.7", "", "2", "1", "", "104", "1", "2", "41", "3.5", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.6", "99.6", "", "", "", "", "97.7"]} +{"pcdb_id": 17085, "brand_name": "Baxi", "model_name": "Avanta 35c Exclusive", "model_qualifier": "", "winter_efficiency_pct": 89.9, "summer_efficiency_pct": 80.9, "comparative_hot_water_efficiency_pct": 59.1, "output_kw_max": 29.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017085", "000005", "0", "2013/Apr/15 09:06", "Remeha", "Baxi", "Avanta 35c Exclusive", "", "", "2012", "current", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "29.4", "29.4", "", "", "89.9", "80.9", "", "59.1", "", "2", "1", "", "102", "1", "2", "115", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.4", "101.0", "", "", "", "", "99.0"]} +{"pcdb_id": 17086, "brand_name": "Baxi", "model_name": "Avanta 39c Exclusive", "model_qualifier": "", "winter_efficiency_pct": 90.2, "summer_efficiency_pct": 81.2, "comparative_hot_water_efficiency_pct": 59.3, "output_kw_max": 33.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017086", "000005", "0", "2013/Apr/15 09:05", "Remeha", "Baxi", "Avanta 39c Exclusive", "", "", "2012", "current", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "33.3", "33.3", "", "", "90.2", "81.2", "", "59.3", "", "2", "1", "", "102", "1", "2", "180", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.3", "101.8", "", "", "", "", "99.6"]} +{"pcdb_id": 17087, "brand_name": "Baxi", "model_name": "Avanta Plus 35c Combi", "model_qualifier": "", "winter_efficiency_pct": 89.9, "summer_efficiency_pct": 81.3, "comparative_hot_water_efficiency_pct": 57.2, "output_kw_max": 29.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017087", "000005", "0", "2013/May/13 09:31", "Remeha", "Baxi", "Avanta Plus 35c Combi", "", "", "2005", "current", "2", "2", "1", "2", "0", "", "", "2", "3", "2", "29.4", "29.4", "", "", "89.9", "81.3", "", "57.2", "", "2", "1", "", "104", "1", "2", "115", "3", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.4", "101.0", "", "", "", "", "99.0"]} +{"pcdb_id": 17088, "brand_name": "Baxi", "model_name": "Avanta Plus 39c Combi", "model_qualifier": "", "winter_efficiency_pct": 90.2, "summer_efficiency_pct": 81.6, "comparative_hot_water_efficiency_pct": 57.4, "output_kw_max": 33.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017088", "000005", "0", "2013/Apr/15 09:05", "Remeha", "Baxi", "Avanta Plus 39c Combi", "", "", "2005", "current", "2", "2", "1", "2", "0", "", "", "2", "3", "2", "33.3", "33.3", "", "", "90.2", "81.6", "", "57.4", "", "2", "1", "", "104", "1", "2", "180", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.3", "101.8", "", "", "", "", "99.6"]} +{"pcdb_id": 17089, "brand_name": "Baxi", "model_name": "Avanta Plus 28c Combi", "model_qualifier": "", "winter_efficiency_pct": 89.6, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 56.9, "output_kw_max": 21.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017089", "000005", "0", "2013/Apr/15 09:04", "Remeha", "Baxi", "Avanta Plus 28c Combi", "", "", "2005", "current", "2", "2", "1", "2", "0", "", "", "2", "3", "2", "21.6", "21.6", "", "", "89.6", "81.0", "", "56.9", "", "2", "1", "", "104", "1", "2", "115", "3", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.5", "100.1", "", "", "", "", "98.3"]} +{"pcdb_id": 17090, "brand_name": "Baxi", "model_name": "Avanta 18h Heat Only", "model_qualifier": "", "winter_efficiency_pct": 89.6, "summer_efficiency_pct": 80.6, "comparative_hot_water_efficiency_pct": 58.8, "output_kw_max": 17.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017090", "000005", "0", "2013/Apr/15 09:04", "Remeha", "Baxi", "Avanta 18h Heat Only", "", "", "2006", "current", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "17.6", "17.6", "", "", "89.6", "80.6", "", "58.8", "", "2", "1", "", "102", "1", "2", "50", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.5", "100.1", "", "", "", "", "98.3"]} +{"pcdb_id": 17091, "brand_name": "Baxi", "model_name": "Avanta 30h Heat Only", "model_qualifier": "", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 29.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017091", "000005", "0", "2013/Apr/15 09:01", "Remeha", "Baxi", "Avanta 30h Heat Only", "", "", "2006", "current", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "29.4", "29.4", "", "", "89.2", "80.2", "", "58.6", "", "2", "1", "", "102", "1", "2", "115", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.4", "99.3", "", "", "", "", "97.6"]} +{"pcdb_id": 17092, "brand_name": "Baxi", "model_name": "Avanta Plus 30s System", "model_qualifier": "", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 29.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017092", "000005", "0", "2013/Apr/15 09:00", "Remeha", "Baxi", "Avanta Plus 30s System", "", "", "2008", "current", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "29.4", "29.4", "", "", "89.2", "80.2", "", "58.6", "", "2", "1", "", "102", "1", "2", "150", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.5", "99.3", "", "", "", "", "97.6"]} +{"pcdb_id": 17093, "brand_name": "Baxi", "model_name": "Avanta 28c Exclusive", "model_qualifier": "", "winter_efficiency_pct": 89.6, "summer_efficiency_pct": 80.6, "comparative_hot_water_efficiency_pct": 58.8, "output_kw_max": 21.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017093", "000005", "0", "2013/Apr/15 08:59", "Remeha", "Baxi", "Avanta 28c Exclusive", "", "", "2012", "current", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "21.6", "21.6", "", "", "89.6", "80.6", "", "58.8", "", "2", "1", "", "102", "1", "2", "115", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.5", "100.1", "", "", "", "", "98.3"]} +{"pcdb_id": 17094, "brand_name": "Baxi", "model_name": "Avanta 15h Heat Only", "model_qualifier": "", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 15.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017094", "000005", "0", "2013/Apr/15 08:57", "Remeha", "Baxi", "Avanta 15h Heat Only", "", "", "2012", "current", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "15", "15", "", "", "89.2", "80.2", "", "58.6", "", "2", "1", "", "102", "1", "2", "50", "33", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.4", "99.2", "", "", "", "", "97.5"]} +{"pcdb_id": 17095, "brand_name": "Baxi", "model_name": "Avanta Plus 24c Combi", "model_qualifier": "", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 56.6, "output_kw_max": 20.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017095", "000005", "0", "2013/Apr/15 08:56", "Remeha", "Baxi", "Avanta Plus 24c Combi", "", "", "2008", "current", "2", "2", "1", "2", "0", "", "", "2", "3", "2", "20", "20", "", "", "89.1", "80.5", "", "56.6", "", "2", "1", "", "104", "1", "2", "115", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.1", "99.2", "", "", "", "", "97.5"]} +{"pcdb_id": 17096, "brand_name": "Baxi", "model_name": "Avanta Plus 18s System", "model_qualifier": "", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 17.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017096", "000005", "0", "2013/May/13 09:21", "Remeha", "Baxi", "Avanta Plus 18s System", "", "", "2008", "current", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "17.6", "17.6", "", "", "89.1", "80.1", "", "58.5", "", "2", "1", "", "102", "1", "2", "115", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.1", "99.2", "", "", "", "", "97.5"]} +{"pcdb_id": 17097, "brand_name": "Baxi", "model_name": "Avanta Plus 24s System", "model_qualifier": "", "winter_efficiency_pct": 89.6, "summer_efficiency_pct": 80.6, "comparative_hot_water_efficiency_pct": 58.8, "output_kw_max": 21.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017097", "000005", "0", "2013/Apr/15 08:55", "Remeha", "Baxi", "Avanta Plus 24s System", "", "", "2005", "current", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "21.6", "21.6", "", "", "89.6", "80.6", "", "58.8", "", "2", "1", "", "102", "1", "2", "115", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.5", "100.1", "", "", "", "", "98.3"]} +{"pcdb_id": 17098, "brand_name": "Baxi", "model_name": "Avanta 24h Heat Only", "model_qualifier": "", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 24.7, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017098", "000005", "0", "2013/Apr/15 09:20", "Remeha", "Baxi", "Avanta 24h Heat Only", "", "", "2008", "current", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "24.7", "24.7", "", "", "89.2", "80.2", "", "58.6", "", "2", "1", "", "102", "1", "2", "50", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.2", "99.3", "", "", "", "", "97.6"]} +{"pcdb_id": 17099, "brand_name": "Main", "model_name": "Combi Eco Classic", "model_qualifier": "30", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 55.9, "output_kw_max": 28.63, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017099", "000005", "0", "2015/Aug/06 13:17", "Baxi Heating UK", "Main", "Combi Eco Classic", "30", "GC 47-467-11", "2013", "2015", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28.63", "28.63", "", "", "88.1", "79.5", "", "55.9", "", "2", "", "", "104", "1", "2", "150", "3.5", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "97.0", "", "", "", "", "95.3"]} +{"pcdb_id": 17100, "brand_name": "Main", "model_name": "Combi Eco Classic", "model_qualifier": "24", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 56.1, "output_kw_max": 25.94, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017100", "000005", "0", "2015/Aug/06 13:17", "Baxi Heating UK", "Main", "Combi Eco Classic", "24", "GC No. 47-467-10", "2013", "2015", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "25.94", "25.94", "", "", "88.4", "79.8", "", "56.1", "", "2", "", "", "104", "1", "2", "150", "3.5", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.7", "97.0", "", "", "", "", "95.7"]} +{"pcdb_id": 17103, "brand_name": "Worcester", "model_name": "Greenstar Danesmoor External", "model_qualifier": "12/18", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 58.8, "output_kw_max": 18.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017103", "000035", "0", "2020/Sep/08 10:38", "Worcester Bosch Group", "Worcester", "Greenstar Danesmoor External", "12/18", "", "2013", "2015", "4", "1", "2", "1", "0", "", "", "2", "2", "1", "12", "18", "", "", "88.3", "80.5", "", "58.8", "", "2", "", "", "201", "1", "1", "145", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.1", "95.4", "", "", "", "", "94.6"]} +{"pcdb_id": 17104, "brand_name": "Worcester", "model_name": "Greenstar Danesmoor", "model_qualifier": "12/18", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 58.8, "output_kw_max": 18.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017104", "000035", "0", "2020/Sep/08 10:38", "Worcester Bosch Group", "Worcester", "Greenstar Danesmoor", "12/18", "", "2013", "2015", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "12", "18", "", "", "88.3", "80.5", "", "58.8", "", "2", "", "", "201", "1", "1", "145", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.1", "95.4", "", "", "", "", "94.6"]} +{"pcdb_id": 17105, "brand_name": "Worcester", "model_name": "Greenstar Danesmoor Utility", "model_qualifier": "12/18", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 58.8, "output_kw_max": 18.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017105", "000035", "0", "2020/Sep/08 10:38", "Worcester Bosch Group", "Worcester", "Greenstar Danesmoor Utility", "12/18", "", "2013", "2015", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "12", "18", "", "", "88.3", "80.5", "", "58.8", "", "2", "", "", "201", "1", "1", "145", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.1", "95.4", "", "", "", "", "94.6"]} +{"pcdb_id": 17106, "brand_name": "Worcester", "model_name": "Greenstar Danesmoor External", "model_qualifier": "18/25", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 58.7, "output_kw_max": 25.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017106", "000035", "0", "2020/Sep/08 10:39", "Worcester Bosch Group", "Worcester", "Greenstar Danesmoor External", "18/25", "", "2013", "2015", "4", "1", "2", "1", "0", "", "", "2", "2", "1", "18", "25", "", "", "88.1", "80.3", "", "58.7", "", "2", "", "", "201", "1", "1", "145", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.9", "95.1", "", "", "", "", "94.3"]} +{"pcdb_id": 17107, "brand_name": "Worcester", "model_name": "Greenstar Danesmoor", "model_qualifier": "18/25", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 58.7, "output_kw_max": 25.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017107", "000035", "0", "2020/Sep/08 10:39", "Worcester Bosch Group", "Worcester", "Greenstar Danesmoor", "18/25", "", "2013", "2015", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "18", "25", "", "", "88.1", "80.3", "", "58.7", "", "2", "", "", "201", "1", "1", "145", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.9", "95.1", "", "", "", "", "94.3"]} +{"pcdb_id": 17108, "brand_name": "Worcester", "model_name": "Greenstar Danesmoor Utility", "model_qualifier": "18/25", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 58.7, "output_kw_max": 25.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017108", "000035", "0", "2020/Sep/08 10:39", "Worcester Bosch Group", "Worcester", "Greenstar Danesmoor Utility", "18/25", "", "2013", "2015", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "18", "25", "", "", "88.1", "80.3", "", "58.7", "", "2", "", "", "201", "1", "1", "145", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.9", "95.1", "", "", "", "", "94.3"]} +{"pcdb_id": 17109, "brand_name": "Worcester", "model_name": "Greenstar Danesmoor External", "model_qualifier": "25/32", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 32.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017109", "000035", "0", "2020/Sep/08 10:39", "Worcester Bosch Group", "Worcester", "Greenstar Danesmoor External", "25/32", "", "2013", "2015", "4", "1", "2", "1", "0", "", "", "2", "2", "1", "25", "32", "", "", "87.9", "80.1", "", "58.5", "", "2", "", "", "201", "1", "1", "150", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.4", "94.3", "", "", "", "", "93.7"]} +{"pcdb_id": 17110, "brand_name": "Worcester", "model_name": "Greenstar Danesmoor", "model_qualifier": "25/32", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 32.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017110", "000035", "0", "2020/Sep/08 10:39", "Worcester Bosch Group", "Worcester", "Greenstar Danesmoor", "25/32", "", "2013", "2015", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "25", "32", "", "", "87.9", "80.1", "", "58.5", "", "2", "", "", "201", "1", "1", "150", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.4", "94.3", "", "", "", "", "93.7"]} +{"pcdb_id": 17111, "brand_name": "Worcester", "model_name": "Greenstar Danesmoor Utility", "model_qualifier": "25/32", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 32.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017111", "000035", "0", "2020/Sep/08 10:40", "Worcester Bosch Group", "Worcester", "Greenstar Danesmoor Utility", "25/32", "", "2013", "2015", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "25", "32", "", "", "87.9", "80.1", "", "58.5", "", "2", "", "", "201", "1", "1", "150", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.4", "94.3", "", "", "", "", "93.7"]} +{"pcdb_id": 17113, "brand_name": "Vokera", "model_name": "Unica", "model_qualifier": "I28", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 86.9, "comparative_hot_water_efficiency_pct": 73.4, "output_kw_max": 19.62, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0095, "loss_factor_f1_kwh_per_day": 1.02018, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017113", "000011", "0", "2015/Jan/19 11:04", "Vokera", "Vokera", "Unica", "I28", "4709412", "2013", "current", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "19.62", "19.62", "", "", "89.0", "86.9", "", "73.4", "", "2", "", "", "104", "1", "2", "120", "4.9", "0", "", "", "", "0", "", "", "", "", "1", "7.178", "0.122", "0.0095", "1.02018", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "", "", "", "", "88.6", "99.0", "", "", "", "", "97.0"]} +{"pcdb_id": 17114, "brand_name": "Vokera", "model_name": "Unica", "model_qualifier": "I32", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 86.9, "comparative_hot_water_efficiency_pct": 72.2, "output_kw_max": 24.58, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0055, "loss_factor_f1_kwh_per_day": 1.15348, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017114", "000011", "0", "2016/Sep/21 11:28", "Vokera", "Vokera", "Unica", "I32", "4736415", "2013", "current", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "24.58", "24.58", "", "", "89.0", "86.9", "", "72.2", "", "2", "", "", "104", "1", "2", "126", "4.9", "0", "", "", "", "0", "", "", "", "", "1", "7.292", "0.14", "0.0055", "1.15348", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "", "", "", "", "88.6", "99.0", "", "", "", "", "97.0"]} +{"pcdb_id": 17115, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "30 Si Compact", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 87.1, "comparative_hot_water_efficiency_pct": 75.0, "output_kw_max": 24.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.001, "loss_factor_f1_kwh_per_day": 0.92442, "loss_factor_f2_kwh_per_day": 0.7998, "rejected_factor_f3_per_litre": 1e-05, "raw": ["017115", "000035", "0", "2020/Apr/09 16:38", "Worcester Bosch Group", "Worcester", "Greenstar", "30 Si Compact", "47-406-52", "2013", "2015", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "89.2", "87.1", "", "75.0", "", "2", "", "", "104", "1", "2", "114", "1.0", "0", "", "", "", "0", "", "", "", "", "2", "7.02", "0.076", "0.001", "0.92442", "13.03", "0.098", "0.0005", "0.7998", "0.00001", "1", "1", "", "0305", "", "", "", "", "", "", "", "", "88.8", "99.6", "", "", "", "", "97.5"]} +{"pcdb_id": 17116, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "30 Si Compact", "winter_efficiency_pct": 90.3, "summer_efficiency_pct": 90.3, "comparative_hot_water_efficiency_pct": 75.2, "output_kw_max": 24.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.0014, "loss_factor_f1_kwh_per_day": 1.05749, "loss_factor_f2_kwh_per_day": 1.02677, "rejected_factor_f3_per_litre": 0.0, "raw": ["017116", "000035", "0", "2020/Apr/09 16:37", "Worcester Bosch Group", "Worcester", "Greenstar", "30 Si Compact", "47-406-53", "2013", "2015", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "90.3", "90.3", "", "75.2", "", "2", "1", "", "104", "1", "2", "114", "1.0", "0", "", "", "", "0", "", "", "", "", "2", "7.16", "0.089", "0.0014", "1.05749", "12.99", "0.105", "0.0015", "1.02677", "0.0", "1", "1", "", "0305", "", "", "", "", "", "", "", "", "90.8", "101.8", "", "", "", "", "99.7"]} +{"pcdb_id": 17117, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "25 Si Compact", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 88.2, "comparative_hot_water_efficiency_pct": 74.6, "output_kw_max": 24.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.0013, "loss_factor_f1_kwh_per_day": 0.96127, "loss_factor_f2_kwh_per_day": 0.9203, "rejected_factor_f3_per_litre": 1e-05, "raw": ["017117", "000035", "0", "2020/Apr/09 16:37", "Worcester Bosch Group", "Worcester", "Greenstar", "25 Si Compact", "47-406-50", "2013", "2015", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "89.2", "88.2", "", "74.6", "", "2", "", "", "104", "1", "2", "104", "1.0", "0", "", "", "", "0", "", "", "", "", "2", "7.06", "0.091", "0.0013", "0.96127", "12.8", "0.114", "0.0007", "0.9203", "0.00001", "1", "1", "", "0305", "", "", "", "", "", "", "", "", "88.8", "99.6", "", "", "", "", "97.5"]} +{"pcdb_id": 17118, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "25 Si Compact", "winter_efficiency_pct": 90.3, "summer_efficiency_pct": 90.3, "comparative_hot_water_efficiency_pct": 75.8, "output_kw_max": 24.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.0014, "loss_factor_f1_kwh_per_day": 0.99958, "loss_factor_f2_kwh_per_day": 0.96912, "rejected_factor_f3_per_litre": 1e-05, "raw": ["017118", "000035", "0", "2020/Apr/09 16:36", "Worcester Bosch Group", "Worcester", "Greenstar", "25 Si Compact", "47-406-51", "2013", "2015", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "90.3", "90.3", "", "75.8", "", "2", "1", "", "104", "1", "2", "104", "1.0", "0", "", "", "", "0", "", "", "", "", "2", "7.1", "0.09", "0.0014", "0.99958", "12.83", "0.111", "0.0007", "0.96912", "0.00001", "1", "1", "", "0305", "", "", "", "", "", "", "", "", "90.8", "101.8", "", "", "", "", "99.7"]} +{"pcdb_id": 17119, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "30 Ri Compact", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 30.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017119", "000035", "0", "2020/Sep/08 10:40", "Worcester Bosch Group", "Worcester", "Greenstar", "30 Ri Compact", "47-406-19", "2013", "2015", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "30", "30", "", "", "88.3", "79.3", "", "57.9", "", "2", "", "", "102", "1", "2", "41.0", "1.0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0305", "", "", "", "", "", "", "", "", "88.2", "97.4", "", "", "", "", "95.7"]} +{"pcdb_id": 17120, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "30 Ri Compact", "winter_efficiency_pct": 89.3, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 30.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017120", "000035", "0", "2020/Sep/08 10:40", "Worcester Bosch Group", "Worcester", "Greenstar", "30 Ri Compact", "47-406-20", "2013", "2015", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "30", "30", "", "", "89.3", "80.3", "", "58.6", "", "2", "1", "", "102", "1", "2", "41.0", "1.0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0305", "", "", "", "", "", "", "", "", "90.2", "99.6", "", "", "", "", "97.8"]} +{"pcdb_id": 17121, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "27 Ri Compact", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 27.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017121", "000035", "0", "2020/Sep/08 10:40", "Worcester Bosch Group", "Worcester", "Greenstar", "27 Ri Compact", "47-406-17", "2013", "2015", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "27", "27", "", "", "88.3", "79.3", "", "57.9", "", "2", "", "", "102", "1", "2", "35", "1.0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0305", "", "", "", "", "", "", "", "", "88.2", "97.4", "", "", "", "", "95.7"]} +{"pcdb_id": 17122, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "27 Ri Compact", "winter_efficiency_pct": 89.3, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 27.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017122", "000035", "0", "2020/Sep/08 10:40", "Worcester Bosch Group", "Worcester", "Greenstar", "27 Ri Compact", "47-406-18", "2013", "2015", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "27", "27", "", "", "89.3", "80.3", "", "58.6", "", "2", "1", "", "102", "1", "2", "35", "1.0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0305", "", "", "", "", "", "", "", "", "90.2", "99.6", "", "", "", "", "97.8"]} +{"pcdb_id": 17123, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "27 I System Compact", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 27.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017123", "000035", "0", "2020/Sep/08 10:40", "Worcester Bosch Group", "Worcester", "Greenstar", "27 I System Compact", "47-406-13", "2013", "2015", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "27", "27", "", "", "88.3", "79.3", "", "57.9", "", "2", "", "", "102", "1", "2", "102", "1.0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0305", "", "", "", "", "", "", "", "", "88.2", "97.4", "", "", "", "", "95.7"]} +{"pcdb_id": 17124, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "27 I System Compact", "winter_efficiency_pct": 89.3, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 27.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017124", "000035", "0", "2020/Sep/08 10:40", "Worcester Bosch Group", "Worcester", "Greenstar", "27 I System Compact", "47-406-14", "2013", "2015", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "27", "27", "", "", "89.3", "80.3", "", "58.6", "", "2", "1", "", "102", "1", "2", "102", "1.0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0305", "", "", "", "", "", "", "", "", "90.2", "99.6", "", "", "", "", "97.8"]} +{"pcdb_id": 17125, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "30 I System Compact", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 30.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017125", "000035", "0", "2020/Sep/08 10:40", "Worcester Bosch Group", "Worcester", "Greenstar", "30 I System Compact", "47-406-15", "2013", "2015", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "30", "30", "", "", "88.3", "79.3", "", "57.9", "", "2", "", "", "102", "1", "2", "108", "1.0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0305", "", "", "", "", "", "", "", "", "88.2", "97.4", "", "", "", "", "95.7"]} +{"pcdb_id": 17126, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "30 I System Compact", "winter_efficiency_pct": 89.3, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 30.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017126", "000035", "0", "2020/Sep/08 10:40", "Worcester Bosch Group", "Worcester", "Greenstar", "30 I System Compact", "47-406-16", "2013", "2015", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "30", "30", "", "", "89.3", "80.3", "", "58.6", "", "2", "1", "", "102", "1", "2", "108", "1.0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0305", "", "", "", "", "", "", "", "", "90.2", "99.6", "", "", "", "", "97.8"]} +{"pcdb_id": 17127, "brand_name": "Ferroli", "model_name": "Modena 18S HE", "model_qualifier": "", "winter_efficiency_pct": 89.6, "summer_efficiency_pct": 80.6, "comparative_hot_water_efficiency_pct": 58.9, "output_kw_max": 17.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017127", "000097", "0", "2013/Jun/25 12:56", "Ferroli", "Ferroli", "Modena 18S HE", "", "", "2012", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "17.4", "17.4", "", "", "89.6", "80.6", "", "58.9", "", "2", "1", "", "102", "1", "2", "100", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.3", "100.3", "", "", "", "", "98.4"]} +{"pcdb_id": 17128, "brand_name": "A O Smith", "model_name": "UB70 G", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 60.1, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017128", "000275", "0", "2013/Jun/26 07:55", "ATAG Verwarming Nederland BV", "A O Smith", "UB70 G", "", "", "2011", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "60.1", "60.1", "", "", "88.8", "79.8", "", "58.3", "", "2", "", "", "102", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.7", "98.9", "", "", "", "", "96.8"]} +{"pcdb_id": 17130, "brand_name": "Ferroli", "model_name": "Modena 27C HE", "model_qualifier": "", "winter_efficiency_pct": 89.6, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 56.9, "output_kw_max": 24.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017130", "000097", "0", "2013/Jun/27 16:52", "Ferroli", "Ferroli", "Modena 27C HE", "", "", "2012", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24.5", "24.5", "", "", "89.6", "81.0", "", "56.9", "", "2", "1", "", "104", "1", "2", "100", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.4", "100.2", "", "", "", "", "98.3"]} +{"pcdb_id": 17131, "brand_name": "Ferroli", "model_name": "Modena 32S HE", "model_qualifier": "", "winter_efficiency_pct": 89.6, "summer_efficiency_pct": 80.6, "comparative_hot_water_efficiency_pct": 58.9, "output_kw_max": 31.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017131", "000097", "0", "2013/Jun/27 16:53", "Ferroli", "Ferroli", "Modena 32S HE", "", "", "2012", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "31.4", "31.4", "", "", "89.6", "80.6", "", "58.9", "", "2", "1", "", "102", "1", "2", "100", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.4", "100.3", "", "", "", "", "98.4"]} +{"pcdb_id": 17132, "brand_name": "Ferroli", "model_name": "Modena 25S HE", "model_qualifier": "", "winter_efficiency_pct": 89.6, "summer_efficiency_pct": 80.6, "comparative_hot_water_efficiency_pct": 58.9, "output_kw_max": 24.55, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017132", "000097", "0", "2013/Jun/27 16:53", "Ferroli", "Ferroli", "Modena 25S HE", "", "", "2012", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "24.55", "24.55", "", "", "89.6", "80.6", "", "58.9", "", "2", "1", "", "102", "1", "2", "100", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.4", "100.2", "", "", "", "", "98.3"]} +{"pcdb_id": 17133, "brand_name": "Sime", "model_name": "Meridian HE", "model_qualifier": "30 C", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 56.0, "output_kw_max": 28.9, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017133", "000213", "0", "2018/Mar/05 14:13", "Fonderie Sime S.p.A.", "Sime", "Meridian HE", "30 C", "", "2013", "2018", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28.9", "28.9", "", "", "88.3", "79.7", "", "56.0", "", "2", "", "", "104", "1", "2", "115", "4.9", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "97.4", "", "", "", "", "95.7"]} +{"pcdb_id": 17134, "brand_name": "Sime", "model_name": "Meridian HE", "model_qualifier": "30 C", "winter_efficiency_pct": 89.3, "summer_efficiency_pct": 80.7, "comparative_hot_water_efficiency_pct": 56.7, "output_kw_max": 28.9, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017134", "000213", "0", "2018/Mar/05 14:13", "Fonderie Sime S.p.A.", "Sime", "Meridian HE", "30 C", "", "2013", "2018", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "28.9", "28.9", "", "", "89.3", "80.7", "", "56.7", "", "2", "1", "", "104", "1", "2", "115", "4.9", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.3", "99.6", "", "", "", "", "97.8"]} +{"pcdb_id": 17135, "brand_name": "Worcester", "model_name": "Greenstar Heatslave II", "model_qualifier": "12/18", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 82.2, "comparative_hot_water_efficiency_pct": 44.8, "output_kw_max": 18.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 1, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017135", "000035", "0", "2024/Jan/31 10:17", "Worcester Bosch Group", "Worcester", "Greenstar Heatslave II", "12/18", "", "2013", "2015", "4", "1", "1", "2", "0", "", "", "2", "3", "1", "12", "18", "", "", "88.3", "82.2", "", "44.8", "", "2", "", "", "203", "1", "1", "230", "1.7", "1", "1", "", "42", "0", "25", "3", "84", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0123", "", "", "", "", "", "", "", "", "91.1", "95.4", "", "", "", "", "94.6"]} +{"pcdb_id": 17136, "brand_name": "Worcester", "model_name": "Greenstar Heatslave II External", "model_qualifier": "12/18", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 82.2, "comparative_hot_water_efficiency_pct": 44.8, "output_kw_max": 18.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 1, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017136", "000035", "0", "2024/Jan/31 10:17", "Worcester Bosch Group", "Worcester", "Greenstar Heatslave II External", "12/18", "", "2013", "2015", "4", "1", "2", "2", "0", "", "", "2", "2", "1", "12", "18", "", "", "88.3", "82.2", "", "44.8", "", "2", "", "", "203", "1", "1", "230", "1.7", "1", "1", "", "42", "0", "25", "3", "84", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0123", "", "", "", "", "", "", "", "", "91.1", "95.4", "", "", "", "", "94.6"]} +{"pcdb_id": 17137, "brand_name": "Worcester", "model_name": "Greenstar Heatslave II", "model_qualifier": "18/25", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 82.0, "comparative_hot_water_efficiency_pct": 44.7, "output_kw_max": 25.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 1, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017137", "000035", "0", "2024/Jan/31 10:17", "Worcester Bosch Group", "Worcester", "Greenstar Heatslave II", "18/25", "", "2013", "2015", "4", "1", "1", "2", "0", "", "", "2", "3", "1", "18", "25", "", "", "88.1", "82.0", "", "44.7", "", "2", "", "", "203", "1", "1", "230", "1.7", "1", "1", "", "42", "0", "25", "3", "86", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0123", "", "", "", "", "", "", "", "", "90.9", "95.1", "", "", "", "", "94.3"]} +{"pcdb_id": 17138, "brand_name": "Worcester", "model_name": "Greenstar Heatslave II External", "model_qualifier": "18/25", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 82.0, "comparative_hot_water_efficiency_pct": 44.7, "output_kw_max": 25.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 1, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017138", "000035", "0", "2024/Jan/31 10:17", "Worcester Bosch Group", "Worcester", "Greenstar Heatslave II External", "18/25", "", "2013", "2015", "4", "1", "2", "2", "0", "", "", "2", "2", "1", "18", "25", "", "", "88.1", "82.0", "", "44.7", "", "2", "", "", "203", "1", "1", "230", "1.7", "1", "1", "", "42", "0", "25", "3", "86", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0123", "", "", "", "", "", "", "", "", "90.9", "95.1", "", "", "", "", "94.3"]} +{"pcdb_id": 17139, "brand_name": "Worcester", "model_name": "Greenstar Heatslave II", "model_qualifier": "25/32", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 81.8, "comparative_hot_water_efficiency_pct": 44.6, "output_kw_max": 32.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 1, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017139", "000035", "0", "2024/Jan/31 10:17", "Worcester Bosch Group", "Worcester", "Greenstar Heatslave II", "25/32", "", "2013", "2015", "4", "1", "1", "2", "0", "", "", "2", "3", "1", "25", "32", "", "", "87.9", "81.8", "", "44.6", "", "2", "", "", "203", "1", "1", "250", "1.7", "1", "1", "", "42", "0", "25", "3", "88", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0123", "", "", "", "", "", "", "", "", "91.4", "94.3", "", "", "", "", "93.7"]} +{"pcdb_id": 17140, "brand_name": "Worcester", "model_name": "Greenstar Heatslave II External", "model_qualifier": "25/32", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 81.8, "comparative_hot_water_efficiency_pct": 44.6, "output_kw_max": 32.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 1, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017140", "000035", "0", "2024/Jan/31 10:17", "Worcester Bosch Group", "Worcester", "Greenstar Heatslave II External", "25/32", "", "2013", "2015", "4", "1", "2", "2", "0", "", "", "2", "2", "1", "25", "32", "", "", "87.9", "81.8", "", "44.6", "", "2", "", "", "203", "1", "1", "250", "1.7", "1", "1", "", "42", "0", "25", "3", "88", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0123", "", "", "", "", "", "", "", "", "91.4", "94.3", "", "", "", "", "93.7"]} +{"pcdb_id": 17141, "brand_name": "Baxi", "model_name": "Duo-tec 2 Combi", "model_qualifier": "40", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 77.8, "output_kw_max": 32.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0036, "loss_factor_f1_kwh_per_day": 0.69163, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017141", "000005", "0", "2015/Aug/06 12:22", "Baxi Heating UK", "Baxi", "Duo-tec 2 Combi", "40", "GC No. 47-075-70", "2011", "2015", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "32", "32", "", "", "88.4", "87.3", "", "77.8", "", "2", "", "", "104", "1", "2", "142", "3.5", "0", "", "", "", "0", "", "", "", "", "1", "6.765", "0.111", "0.0036", "0.69163", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.0", "96.9", "", "", "", "", "95.6"]} +{"pcdb_id": 17142, "brand_name": "Baxi", "model_name": "Duo-tec 2 Combi", "model_qualifier": "28 Compact", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 77.3, "output_kw_max": 24.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0044, "loss_factor_f1_kwh_per_day": 0.73349, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017142", "000005", "0", "2015/Aug/06 12:23", "Baxi Heating UK", "Baxi", "Duo-tec 2 Combi", "28 Compact", "GC No. 47-075-72", "2013", "2015", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "88.4", "87.3", "", "77.3", "", "2", "", "", "104", "1", "2", "116", "3.5", "0", "", "", "", "0", "", "", "", "", "1", "6.813", "0.118", "0.0044", "0.73349", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.0", "96.9", "", "", "", "", "95.6"]} +{"pcdb_id": 17143, "brand_name": "Baxi", "model_name": "Duo-tec 2 Combi", "model_qualifier": "28", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 77.3, "output_kw_max": 24.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0044, "loss_factor_f1_kwh_per_day": 0.73349, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017143", "000005", "0", "2015/Aug/06 12:23", "Baxi Heating UK", "Baxi", "Duo-tec 2 Combi", "28", "GV No. 47-075-68", "2013", "2015", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "88.4", "87.3", "", "77.3", "", "2", "", "", "104", "1", "2", "116", "3.5", "0", "", "", "", "0", "", "", "", "", "1", "6.813", "0.118", "0.0044", "0.73349", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.0", "96.9", "", "", "", "", "95.6"]} +{"pcdb_id": 17144, "brand_name": "Baxi", "model_name": "Megaflow 2 System", "model_qualifier": "24 Compact", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 24.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017144", "000005", "0", "2015/Aug/06 12:25", "Baxi Heating UK", "Baxi", "Megaflow 2 System", "24 Compact", "GV No. 41-075-092", "2011", "2015", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24", "24", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "104", "3.5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.0", "96.9", "", "", "", "", "95.6"]} +{"pcdb_id": 17145, "brand_name": "Baxi", "model_name": "Duo-tec 2 Combi", "model_qualifier": "24", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 77.6, "output_kw_max": 20.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0043, "loss_factor_f1_kwh_per_day": 0.70793, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017145", "000005", "0", "2015/Aug/06 12:25", "Baxi Heating UK", "Baxi", "Duo-tec 2 Combi", "24", "GC No. 47-075-67", "2011", "2015", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "20", "20", "", "", "88.4", "87.3", "", "77.6", "", "2", "", "", "104", "1", "2", "104", "3.5", "0", "", "", "", "0", "", "", "", "", "1", "6.786", "0.118", "0.0043", "0.70793", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.0", "96.9", "", "", "", "", "95.6"]} +{"pcdb_id": 17146, "brand_name": "Johnson & Starley", "model_name": "QuanTec", "model_qualifier": "24RK", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 23.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017146", "000239", "0", "2015/Sep/21 14:23", "Johnson & Starley", "Johnson & Starley", "QuanTec", "24RK", "41-416-20", "2013", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "23.4", "23.4", "", "", "88.9", "79.9", "", "58.4", "", "2", "", "", "102", "1", "2", "20", "6.87", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "", "", "", "", "87.9", "99.1", "", "", "", "", "97.0"]} +{"pcdb_id": 17147, "brand_name": "Johnson & Starley", "model_name": "QuanTec", "model_qualifier": "16RK", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 16.76, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017147", "000239", "0", "2015/Sep/21 14:23", "Johnson & Starley", "Johnson & Starley", "QuanTec", "16RK", "41-416-19", "2013", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "16.76", "16.76", "", "", "89.0", "80.0", "", "58.4", "", "2", "", "", "102", "1", "2", "20", "6.87", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "", "", "", "", "88.7", "98.9", "", "", "", "", "97.0"]} +{"pcdb_id": 17149, "brand_name": "Rotex", "model_name": "A1 BO 15-e", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 80.7, "comparative_hot_water_efficiency_pct": 59.0, "output_kw_max": 15.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017149", "000246", "0", "2013/Aug/23 11:31", "Rotex Heating Systems", "Rotex", "A1 BO 15-e", "", "", "2013", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "15", "15", "", "", "88.5", "80.7", "", "59.0", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.5", "95.9", "", "", "", "", "95.0"]} +{"pcdb_id": 17150, "brand_name": "Rotex", "model_name": "A1 BO 20-e", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 80.6, "comparative_hot_water_efficiency_pct": 58.9, "output_kw_max": 20.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017150", "000246", "0", "2013/Aug/23 11:31", "Rotex Heating Systems", "Rotex", "A1 BO 20-e", "", "", "2013", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "20", "20", "", "", "88.4", "80.6", "", "58.9", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.5", "95.5", "", "", "", "", "94.7"]} +{"pcdb_id": 17151, "brand_name": "Rotex", "model_name": "A1 BO 27-e", "model_qualifier": "", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 27.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017151", "000246", "0", "2013/Aug/23 11:31", "Rotex Heating Systems", "Rotex", "A1 BO 27-e", "", "", "2013", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "27", "27", "", "", "87.9", "80.1", "", "58.5", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.9", "94.5", "", "", "", "", "93.8"]} +{"pcdb_id": 17152, "brand_name": "Rotex", "model_name": "A1 BO 34-e", "model_qualifier": "", "winter_efficiency_pct": 87.6, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 34.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017152", "000246", "0", "2013/Aug/23 11:32", "Rotex Heating Systems", "Rotex", "A1 BO 34-e", "", "", "2013", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "34", "34", "", "", "87.6", "79.8", "", "58.3", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.5", "93.8", "", "", "", "", "93.2"]} +{"pcdb_id": 17157, "brand_name": "Ferroli", "model_name": "T-One", "model_qualifier": "25C HE", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 86.8, "comparative_hot_water_efficiency_pct": 71.8, "output_kw_max": 24.1, "final_year_of_manufacture": 2017, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0043, "loss_factor_f1_kwh_per_day": 1.19581, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017157", "000097", "0", "2017/Aug/07 17:02", "Ferroli", "Ferroli", "T-One", "25C HE", "", "2013", "2017", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.1", "24.1", "", "", "88.5", "86.8", "", "71.8", "", "2", "", "", "104", "1", "2", "100", "", "0", "", "", "", "0", "", "", "", "", "1", "7.3361", "0.07487", "0.0043", "1.19581", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "98.0", "", "", "", "", "96.2"]} +{"pcdb_id": 17158, "brand_name": "Ferroli", "model_name": "Modena 32C HE", "model_qualifier": "", "winter_efficiency_pct": 89.6, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 57.0, "output_kw_max": 29.04, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017158", "000097", "0", "2013/Oct/18 11:19", "Ferroli", "Ferroli", "Modena 32C HE", "", "", "2012", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "29.04", "29.04", "", "", "89.6", "81.0", "", "57.0", "", "2", "1", "", "104", "1", "2", "100", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.4", "100.3", "", "", "", "", "98.4"]} +{"pcdb_id": 17159, "brand_name": "iQE", "model_name": "Horizon", "model_qualifier": "15/26", "winter_efficiency_pct": 87.8, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 26.4, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017159", "000276", "0", "2016/May/16 13:21", "Grant Engineering", "iQE", "Horizon", "15/26", "", "2013", "2015", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "15.9", "26.4", "", "", "87.8", "80.0", "", "58.4", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.4", "94.4", "", "", "", "", "93.6"]} +{"pcdb_id": 17160, "brand_name": "iQE", "model_name": "Horizon", "model_qualifier": "26/35", "winter_efficiency_pct": 87.5, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 35.3, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017160", "000276", "0", "2016/May/16 13:21", "Grant Engineering", "iQE", "Horizon", "26/35", "", "2013", "2015", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "26.3", "35.3", "", "", "87.5", "79.7", "", "58.2", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.3", "93.8", "", "", "", "", "93.1"]} +{"pcdb_id": 17161, "brand_name": "iQE", "model_name": "Horizon", "model_qualifier": "OM15/26", "winter_efficiency_pct": 87.8, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 26.3, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017161", "000276", "0", "2016/May/16 13:22", "Grant Engineering", "iQE", "Horizon", "OM15/26", "", "2013", "2015", "4", "1", "2", "1", "0", "", "", "2", "3", "2", "15.9", "26.3", "", "", "87.8", "80.0", "", "58.4", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.4", "94.4", "", "", "", "", "93.6"]} +{"pcdb_id": 17162, "brand_name": "iQE", "model_name": "Horizon", "model_qualifier": "OM26/35", "winter_efficiency_pct": 87.5, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 35.3, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017162", "000276", "0", "2016/May/16 13:22", "Grant Engineering", "iQE", "Horizon", "OM26/35", "", "2013", "2015", "4", "1", "2", "1", "0", "", "", "2", "3", "2", "26.3", "35.3", "", "", "87.5", "79.7", "", "58.2", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.3", "93.8", "", "", "", "", "93.1"]} +{"pcdb_id": 17163, "brand_name": "iQE", "model_name": "Horizon", "model_qualifier": "COMBI26", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 81.7, "comparative_hot_water_efficiency_pct": 57.5, "output_kw_max": 26.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017163", "000276", "0", "2016/May/16 13:22", "Grant Engineering", "iQE", "Horizon", "COMBI26", "", "2013", "2015", "4", "1", "1", "2", "0", "", "", "2", "3", "2", "26", "26", "", "", "89.1", "81.7", "", "57.5", "", "2", "", "", "202", "1", "1", "", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "93.6", "96.4", "", "", "", "", "95.9"]} +{"pcdb_id": 17164, "brand_name": "iQE", "model_name": "Horizon", "model_qualifier": "OMCOMBI26", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 81.7, "comparative_hot_water_efficiency_pct": 57.5, "output_kw_max": 26.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017164", "000276", "0", "2016/May/16 13:22", "Grant Engineering", "iQE", "Horizon", "OMCOMBI26", "", "2013", "2015", "4", "1", "2", "2", "0", "", "", "2", "3", "2", "26", "26", "", "", "89.1", "81.7", "", "57.5", "", "2", "", "", "202", "1", "1", "", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "93.6", "96.4", "", "", "", "", "95.9"]} +{"pcdb_id": 17166, "brand_name": "Daikin", "model_name": "EHYKOMB33AA", "model_qualifier": "", "winter_efficiency_pct": 89.5, "summer_efficiency_pct": 80.9, "comparative_hot_water_efficiency_pct": 56.9, "output_kw_max": 26.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017166", "000278", "0", "2014/Oct/15 10:21", "Daikin Europe NV", "Daikin", "EHYKOMB33AA", "", "", "2013", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "26.6", "26.6", "", "", "89.5", "80.9", "", "56.9", "", "2", "1", "", "104", "1", "2", "55", "1.9", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.9", "99.7", "", "", "", "", "98.1"]} +{"pcdb_id": 17167, "brand_name": "Daikin", "model_name": "EHYKOMB33AA", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 56.2, "output_kw_max": 26.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017167", "000278", "0", "2013/Sep/27 09:18", "Daikin Europe NV", "Daikin", "EHYKOMB33AA", "", "GC 47-464-01", "2013", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "26.6", "26.6", "", "", "88.5", "79.9", "", "56.2", "", "2", "", "", "104", "1", "2", "55", "1.9", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.9", "97.6", "", "", "", "", "95.9"]} +{"pcdb_id": 17168, "brand_name": "Rotex", "model_name": "GCU Compact 533 BIV", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 81.2, "comparative_hot_water_efficiency_pct": 37.9, "output_kw_max": 31.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017168", "000246", "0", "2024/Jan/31 10:17", "Rotex Heating Systems", "Rotex", "GCU Compact 533 BIV", "", "", "2013", "current", "1", "1", "1", "2", "0", "", "", "2", "3", "2", "31", "31", "", "", "88.0", "81.2", "", "37.9", "", "2", "", "", "106", "1", "2", "114", "6.7", "2", "2", "0", "500", "0", "80", "2", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "96.8", "", "", "", "", "95.1"]} +{"pcdb_id": 17169, "brand_name": "Rotex", "model_name": "GCU Compact 533", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 81.2, "comparative_hot_water_efficiency_pct": 37.9, "output_kw_max": 31.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017169", "000246", "0", "2024/Jan/31 10:17", "Rotex Heating Systems", "Rotex", "GCU Compact 533", "", "", "2013", "current", "1", "1", "1", "2", "0", "", "", "2", "3", "2", "31", "31", "", "", "88.0", "81.2", "", "37.9", "", "2", "", "", "106", "1", "2", "114", "6.7", "2", "2", "0", "500", "0", "80", "2", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "96.8", "", "", "", "", "95.1"]} +{"pcdb_id": 17170, "brand_name": "Rotex", "model_name": "GCU Compact 524 BIV", "model_qualifier": "", "winter_efficiency_pct": 87.3, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 37.6, "output_kw_max": 24.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017170", "000246", "0", "2024/Jan/31 10:17", "Rotex Heating Systems", "Rotex", "GCU Compact 524 BIV", "", "", "2013", "current", "1", "1", "1", "2", "0", "", "", "2", "3", "2", "24", "24", "", "", "87.3", "80.5", "", "37.6", "", "2", "", "", "106", "1", "2", "112", "6.7", "2", "2", "0", "500", "0", "80", "2", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "85.8", "96.0", "", "", "", "", "94.1"]} +{"pcdb_id": 17171, "brand_name": "Rotex", "model_name": "GCU Compact 524", "model_qualifier": "", "winter_efficiency_pct": 87.3, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 37.6, "output_kw_max": 24.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017171", "000246", "0", "2024/Jan/31 10:17", "Rotex Heating Systems", "Rotex", "GCU Compact 524", "", "", "2013", "current", "1", "1", "1", "2", "0", "", "", "2", "3", "2", "24", "24", "", "", "87.3", "80.5", "", "37.6", "", "2", "", "", "106", "1", "2", "112", "6.7", "2", "2", "0", "500", "0", "80", "2", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "85.8", "96.0", "", "", "", "", "94.1"]} +{"pcdb_id": 17172, "brand_name": "Rotex", "model_name": "GCU Compact 515 BIV", "model_qualifier": "", "winter_efficiency_pct": 87.7, "summer_efficiency_pct": 80.9, "comparative_hot_water_efficiency_pct": 37.8, "output_kw_max": 33.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017172", "000246", "0", "2024/Jan/31 10:17", "Rotex Heating Systems", "Rotex", "GCU Compact 515 BIV", "", "", "2013", "current", "1", "1", "1", "2", "0", "", "", "2", "3", "2", "33", "33", "", "", "87.7", "80.9", "", "37.8", "", "2", "", "", "106", "1", "2", "96.1", "6.7", "2", "2", "0", "500", "0", "80", "2", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.1", "96.3", "", "", "", "", "94.6"]} +{"pcdb_id": 17173, "brand_name": "Rotex", "model_name": "GCU Compact 515", "model_qualifier": "", "winter_efficiency_pct": 87.7, "summer_efficiency_pct": 80.9, "comparative_hot_water_efficiency_pct": 37.8, "output_kw_max": 15.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017173", "000246", "0", "2024/Jan/31 10:17", "Rotex Heating Systems", "Rotex", "GCU Compact 515", "", "", "2013", "current", "1", "1", "1", "2", "0", "", "", "2", "3", "2", "15", "15", "", "", "87.7", "80.9", "", "37.8", "", "2", "", "", "106", "1", "2", "96.1", "6.7", "2", "2", "0", "500", "0", "80", "2", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.1", "96.3", "", "", "", "", "94.6"]} +{"pcdb_id": 17174, "brand_name": "Rotex", "model_name": "GCU Compact 324 BIV", "model_qualifier": "", "winter_efficiency_pct": 87.3, "summer_efficiency_pct": 80.4, "comparative_hot_water_efficiency_pct": 39.4, "output_kw_max": 24.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017174", "000246", "0", "2024/Jan/31 10:17", "Rotex Heating Systems", "Rotex", "GCU Compact 324 BIV", "", "", "2013", "current", "1", "1", "1", "2", "0", "", "", "2", "3", "2", "24", "24", "", "", "87.3", "80.4", "", "39.4", "", "2", "", "", "106", "1", "2", "112", "6.7", "2", "2", "0", "300", "0", "52", "2", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "85.8", "96.0", "", "", "", "", "94.1"]} +{"pcdb_id": 17175, "brand_name": "Rotex", "model_name": "GCU Compact 324", "model_qualifier": "", "winter_efficiency_pct": 87.3, "summer_efficiency_pct": 80.4, "comparative_hot_water_efficiency_pct": 39.4, "output_kw_max": 24.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017175", "000246", "0", "2024/Jan/31 10:17", "Rotex Heating Systems", "Rotex", "GCU Compact 324", "", "", "2013", "current", "1", "1", "1", "2", "0", "", "", "2", "3", "2", "24", "24", "", "", "87.3", "80.4", "", "39.4", "", "2", "", "", "106", "1", "2", "112", "6.7", "2", "2", "0", "300", "0", "52", "2", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "85.8", "96.0", "", "", "", "", "94.1"]} +{"pcdb_id": 17176, "brand_name": "Rotex", "model_name": "GCU Compact 315 BIV", "model_qualifier": "", "winter_efficiency_pct": 87.7, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 39.6, "output_kw_max": 15.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017176", "000246", "0", "2024/Jan/31 10:17", "Rotex Heating Systems", "Rotex", "GCU Compact 315 BIV", "", "", "2013", "current", "1", "1", "1", "2", "0", "", "", "2", "3", "2", "15", "15", "", "", "87.7", "80.8", "", "39.6", "", "2", "", "", "106", "1", "2", "96.1", "6.7", "2", "2", "0", "300", "0", "52", "2", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.1", "96.3", "", "", "", "", "94.6"]} +{"pcdb_id": 17177, "brand_name": "Rotex", "model_name": "GCU Compact 315", "model_qualifier": "", "winter_efficiency_pct": 87.7, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 39.6, "output_kw_max": 15.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017177", "000246", "0", "2024/Jan/31 10:17", "Rotex Heating Systems", "Rotex", "GCU Compact 315", "", "", "2013", "current", "1", "1", "1", "2", "0", "", "", "2", "3", "2", "15", "15", "", "", "87.7", "80.8", "", "39.6", "", "2", "", "", "106", "1", "2", "96.1", "6.7", "2", "2", "0", "300", "0", "52", "2", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.1", "96.3", "", "", "", "", "94.6"]} +{"pcdb_id": 17178, "brand_name": "Ideal", "model_name": "LOGIC CODE COMBI", "model_qualifier": "ES26", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 79.0, "output_kw_max": 24.2, "final_year_of_manufacture": 2016, "subsidiary_type": 1, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0013, "loss_factor_f1_kwh_per_day": 0.60624, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017178", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "LOGIC CODE COMBI", "ES26", "47-349-04", "2013", "2016", "1", "2", "1", "2", "1", "", "", "2", "2", "2", "24.2", "24.2", "", "", "88.4", "87.3", "", "79.0", "", "2", "", "", "104", "1", "2", "146", "1", "0", "", "", "", "0", "", "", "", "", "1", "6.667", "0.1818", "0.0013", "0.60624", "", "", "", "", "", "0", "", "", "0035", "", "", "", "", "", "", "", "", "89.8", "96.9", "", "", "", "", "95.6"]} +{"pcdb_id": 17179, "brand_name": "Ideal", "model_name": "LOGIC CODE COMBI", "model_qualifier": "ES33", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 81.4, "output_kw_max": 24.2, "final_year_of_manufacture": 2016, "subsidiary_type": 1, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.003, "loss_factor_f1_kwh_per_day": 0.40776, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017179", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "LOGIC CODE COMBI", "ES33", "47-349-05", "2013", "2016", "1", "2", "1", "2", "1", "", "", "2", "2", "2", "24.2", "24.2", "", "", "88.4", "87.3", "", "81.4", "", "2", "", "", "104", "1", "2", "152", "1", "0", "", "", "", "0", "", "", "", "", "1", "6.468", "0.1831", "0.003", "0.40776", "", "", "", "", "", "0", "", "", "0035", "", "", "", "", "", "", "", "", "90.0", "96.9", "", "", "", "", "95.6"]} +{"pcdb_id": 17180, "brand_name": "Ideal", "model_name": "LOGIC CODE COMBI", "model_qualifier": "ES38", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 80.4, "output_kw_max": 24.2, "final_year_of_manufacture": 2016, "subsidiary_type": 1, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0011, "loss_factor_f1_kwh_per_day": 0.49271, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017180", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "LOGIC CODE COMBI", "ES38", "47-349-06", "2013", "2016", "1", "2", "1", "2", "1", "", "", "2", "2", "2", "24.2", "24.2", "", "", "88.3", "87.3", "", "80.4", "", "2", "", "", "104", "1", "2", "177", "1", "0", "", "", "", "0", "", "", "", "", "1", "6.5486", "0.1612", "0.0011", "0.49271", "", "", "", "", "", "0", "", "", "0035", "", "", "", "", "", "", "", "", "89.8", "96.9", "", "", "", "", "95.5"]} +{"pcdb_id": 17181, "brand_name": "Ideal", "model_name": "Project Heat", "model_qualifier": "15", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 15.0, "final_year_of_manufacture": 2014, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017181", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "Project Heat", "15", "41-750-57", "2013", "2014", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "15", "15", "", "", "88.6", "79.6", "", "58.2", "", "2", "", "", "102", "1", "2", "26", "1", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.7", "97.7", "", "", "", "", "96.2"]} +{"pcdb_id": 17182, "brand_name": "Ideal", "model_name": "Project Heat", "model_qualifier": "24", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 24.2, "final_year_of_manufacture": 2014, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017182", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "Project Heat", "24", "41-750-58", "2013", "2014", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "88.8", "79.8", "", "58.3", "", "2", "", "", "102", "1", "2", "46", "1", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.6", "98.0", "", "", "", "", "96.4"]} +{"pcdb_id": 17183, "brand_name": "Ideal", "model_name": "Project System", "model_qualifier": "15", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 15.0, "final_year_of_manufacture": 2014, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017183", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "Project System", "15", "41-750-59", "2013", "2014", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "15", "15", "", "", "88.6", "79.6", "", "58.2", "", "2", "", "", "102", "1", "2", "126", "1", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.7", "97.7", "", "", "", "", "96.2"]} +{"pcdb_id": 17184, "brand_name": "Ideal", "model_name": "Project System", "model_qualifier": "24", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 24.2, "final_year_of_manufacture": 2014, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017184", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "Project System", "24", "41-750-60", "2013", "2014", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "88.8", "79.8", "", "58.3", "", "2", "", "", "102", "1", "2", "146", "1", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.6", "98.0", "", "", "", "", "96.4"]} +{"pcdb_id": 17185, "brand_name": "iQE", "model_name": "Comfort", "model_qualifier": "30", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 56.0, "output_kw_max": 28.9, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017185", "000273", "0", "2015/Oct/01 13:44", "Fonderie Sime S.p.A.", "iQE", "Comfort", "30", "47-283-47", "2013", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28.9", "28.9", "", "", "88.3", "79.7", "", "56.0", "", "2", "", "", "104", "1", "2", "115", "4.9", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "97.4", "", "", "", "", "95.7"]} +{"pcdb_id": 17186, "brand_name": "iQE", "model_name": "Comfort", "model_qualifier": "30", "winter_efficiency_pct": 89.3, "summer_efficiency_pct": 80.7, "comparative_hot_water_efficiency_pct": 56.7, "output_kw_max": 28.9, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017186", "000273", "0", "2015/Oct/01 13:44", "Fonderie Sime S.p.A.", "iQE", "Comfort", "30", "", "2013", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "28.9", "28.9", "", "", "89.3", "80.7", "", "56.7", "", "2", "1", "", "104", "1", "2", "115", "4.9", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.3", "99.6", "", "", "", "", "97.8"]} +{"pcdb_id": 17187, "brand_name": "Worcester", "model_name": "Greenstar Danesmoor System External", "model_qualifier": "12/18", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 58.8, "output_kw_max": 18.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017187", "000035", "0", "2020/Sep/08 10:41", "Bosch Thermotechnology", "Worcester", "Greenstar Danesmoor System External", "12/18", "", "2013", "2015", "4", "1", "2", "1", "0", "", "", "2", "2", "1", "12", "18", "", "", "88.3", "80.5", "", "58.8", "", "2", "", "", "201", "1", "1", "208", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.1", "95.4", "", "", "", "", "94.6"]} +{"pcdb_id": 17188, "brand_name": "Worcester", "model_name": "Greenstar Danesmoor System External", "model_qualifier": "18/25", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 58.7, "output_kw_max": 25.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017188", "000035", "0", "2020/Sep/08 10:42", "Bosch Thermotechnology", "Worcester", "Greenstar Danesmoor System External", "18/25", "", "2013", "2015", "4", "1", "2", "1", "0", "", "", "2", "2", "1", "18", "25", "", "", "88.1", "80.3", "", "58.7", "", "2", "", "", "201", "1", "1", "208", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.9", "95.1", "", "", "", "", "94.3"]} +{"pcdb_id": 17189, "brand_name": "Worcester", "model_name": "Greenstar Danesmoor System External", "model_qualifier": "25/32", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 32.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017189", "000035", "0", "2020/Sep/08 10:42", "Bosch Thermotechnology", "Worcester", "Greenstar Danesmoor System External", "25/32", "", "2013", "2015", "4", "1", "2", "1", "0", "", "", "2", "2", "1", "25", "32", "", "", "87.9", "80.1", "", "58.5", "", "2", "", "", "201", "1", "1", "208", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.4", "94.3", "", "", "", "", "93.7"]} +{"pcdb_id": 17190, "brand_name": "Worcester", "model_name": "Greenstar Danesmoor System", "model_qualifier": "12/18", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 58.8, "output_kw_max": 18.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017190", "000035", "0", "2020/Sep/08 10:42", "Bosch Thermotechnology", "Worcester", "Greenstar Danesmoor System", "12/18", "", "2013", "2015", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "12", "18", "", "", "88.3", "80.5", "", "58.8", "", "2", "", "", "201", "1", "1", "208", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.1", "95.4", "", "", "", "", "94.6"]} +{"pcdb_id": 17191, "brand_name": "Worcester", "model_name": "Greenstar Danesmoor System", "model_qualifier": "18/25", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 58.7, "output_kw_max": 25.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017191", "000035", "0", "2020/Sep/08 10:42", "Bosch Thermotechnology", "Worcester", "Greenstar Danesmoor System", "18/25", "", "2013", "2015", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "18", "25", "", "", "88.1", "80.3", "", "58.7", "", "2", "", "", "201", "1", "1", "208", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.9", "95.1", "", "", "", "", "94.3"]} +{"pcdb_id": 17192, "brand_name": "Worcester", "model_name": "Greenstar Danesmoor System", "model_qualifier": "25/32", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 32.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017192", "000035", "0", "2020/Sep/08 10:42", "Bosch Thermotechnology", "Worcester", "Greenstar Danesmoor System", "25/32", "", "2013", "2015", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "25", "32", "", "", "87.9", "80.1", "", "58.5", "", "2", "", "", "201", "1", "1", "208", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.4", "94.3", "", "", "", "", "93.7"]} +{"pcdb_id": 17193, "brand_name": "Worcester", "model_name": "Greenstar Danesmoor System Utility", "model_qualifier": "12/18", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 58.8, "output_kw_max": 18.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017193", "000035", "0", "2020/Sep/08 10:42", "Bosch Thermotechnology", "Worcester", "Greenstar Danesmoor System Utility", "12/18", "", "2013", "2015", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "12", "18", "", "", "88.3", "80.5", "", "58.8", "", "2", "", "", "201", "1", "1", "208", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.1", "95.4", "", "", "", "", "94.6"]} +{"pcdb_id": 17194, "brand_name": "Worcester", "model_name": "Greenstar Danesmoor System Utility", "model_qualifier": "18/25", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 58.7, "output_kw_max": 25.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017194", "000035", "0", "2020/Sep/08 10:42", "Bosch Thermotechnology", "Worcester", "Greenstar Danesmoor System Utility", "18/25", "", "2013", "2015", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "18", "25", "", "", "88.1", "80.3", "", "58.7", "", "2", "", "", "201", "1", "1", "208", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.9", "95.1", "", "", "", "", "94.3"]} +{"pcdb_id": 17195, "brand_name": "Worcester", "model_name": "Greenstar Danesmoor System Utility", "model_qualifier": "25/32", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 32.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017195", "000035", "0", "2020/Sep/08 10:42", "Bosch Thermotechnology", "Worcester", "Greenstar Danesmoor System Utility", "25/32", "", "2013", "2015", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "25", "32", "", "", "87.9", "80.1", "", "58.5", "", "2", "", "", "201", "1", "1", "208", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.4", "94.3", "", "", "", "", "93.7"]} +{"pcdb_id": 17196, "brand_name": "Rotex", "model_name": "GCU Compact 315", "model_qualifier": "", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 81.8, "comparative_hot_water_efficiency_pct": 40.1, "output_kw_max": 15.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017196", "000246", "0", "2024/Jan/31 10:17", "Rotex Heating Systems", "Rotex", "GCU Compact 315", "", "", "2013", "current", "2", "1", "1", "2", "0", "", "", "2", "3", "2", "15", "15", "", "", "88.7", "81.8", "", "40.1", "", "2", "1", "", "106", "1", "2", "96.1", "6.7", "2", "2", "1", "300", "0", "52", "2", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.1", "98.5", "", "", "", "", "96.7"]} +{"pcdb_id": 17197, "brand_name": "Rotex", "model_name": "GCU Compact 315 BIV", "model_qualifier": "", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 81.8, "comparative_hot_water_efficiency_pct": 40.1, "output_kw_max": 15.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017197", "000246", "0", "2024/Jan/31 10:17", "Rotex Heating Systems", "Rotex", "GCU Compact 315 BIV", "", "", "2013", "current", "2", "1", "2", "2", "0", "", "", "2", "3", "2", "15", "15", "", "", "88.7", "81.8", "", "40.1", "", "2", "1", "", "106", "1", "2", "96.1", "6.7", "2", "2", "", "300", "0", "52", "2", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.1", "98.5", "", "", "", "", "96.7"]} +{"pcdb_id": 17198, "brand_name": "Rotex", "model_name": "GCU Compact 324", "model_qualifier": "", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 81.4, "comparative_hot_water_efficiency_pct": 39.9, "output_kw_max": 24.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017198", "000246", "0", "2024/Jan/31 10:17", "Rotex Heating Systems", "Rotex", "GCU Compact 324", "", "", "2013", "current", "2", "1", "1", "2", "0", "", "", "2", "3", "2", "24", "24", "", "", "88.2", "81.4", "", "39.9", "", "2", "1", "", "106", "1", "2", "112", "6.7", "2", "2", "0", "300", "0", "52", "2", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.7", "98.2", "", "", "", "", "96.2"]} +{"pcdb_id": 17199, "brand_name": "Rotex", "model_name": "GCU Compact 324 BIV", "model_qualifier": "", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 81.4, "comparative_hot_water_efficiency_pct": 39.9, "output_kw_max": 24.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017199", "000246", "0", "2024/Jan/31 10:17", "Rotex Heating Systems", "Rotex", "GCU Compact 324 BIV", "", "", "2013", "current", "2", "1", "1", "2", "0", "", "", "2", "3", "2", "24", "24", "", "", "88.2", "81.4", "", "39.9", "", "2", "1", "", "106", "1", "2", "112", "6.7", "2", "2", "0", "300", "0", "52", "2", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.7", "98.2", "", "", "", "", "96.2"]} +{"pcdb_id": 17200, "brand_name": "Rotex", "model_name": "GCU Compact 515", "model_qualifier": "", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 81.9, "comparative_hot_water_efficiency_pct": 38.2, "output_kw_max": 15.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017200", "000246", "0", "2024/Jan/31 10:17", "Rotex Heating Systems", "Rotex", "GCU Compact 515", "", "", "2013", "current", "2", "1", "1", "2", "0", "", "", "2", "3", "2", "15", "15", "", "", "88.7", "81.9", "", "38.2", "", "2", "1", "", "106", "1", "2", "96.1", "6.7", "2", "2", "0", "500", "0", "80", "2", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.1", "98.5", "", "", "", "", "96.7"]} +{"pcdb_id": 17201, "brand_name": "Rotex", "model_name": "GCU Compact 515 BIV", "model_qualifier": "", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 81.9, "comparative_hot_water_efficiency_pct": 38.2, "output_kw_max": 15.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017201", "000246", "0", "2024/Jan/31 10:17", "Rotex Heating Systems", "Rotex", "GCU Compact 515 BIV", "", "", "2013", "current", "2", "1", "1", "2", "0", "", "", "2", "3", "2", "15", "15", "", "", "88.7", "81.9", "", "38.2", "", "2", "1", "", "106", "1", "2", "96.1", "6.7", "2", "2", "0", "500", "0", "80", "2", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.1", "98.5", "", "", "", "", "96.7"]} +{"pcdb_id": 17202, "brand_name": "Rotex", "model_name": "GCU Compact 524", "model_qualifier": "", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 81.4, "comparative_hot_water_efficiency_pct": 38.0, "output_kw_max": 24.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017202", "000246", "0", "2024/Jan/31 10:17", "Rotex Heating Systems", "Rotex", "GCU Compact 524", "", "", "2013", "current", "2", "1", "1", "2", "0", "", "", "2", "3", "2", "24", "24", "", "", "88.2", "81.4", "", "38.0", "", "2", "1", "", "106", "1", "2", "112", "6.7", "2", "2", "0", "500", "0", "80", "2", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.7", "98.2", "", "", "", "", "96.2"]} +{"pcdb_id": 17203, "brand_name": "Rotex", "model_name": "GCU Compact 524 BIV", "model_qualifier": "", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 81.4, "comparative_hot_water_efficiency_pct": 38.0, "output_kw_max": 24.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017203", "000246", "0", "2024/Jan/31 10:17", "Rotex Heating Systems", "Rotex", "GCU Compact 524 BIV", "", "", "2013", "current", "2", "1", "1", "2", "0", "", "", "2", "3", "2", "24", "24", "", "", "88.2", "81.4", "", "38.0", "", "2", "1", "", "106", "1", "2", "112", "6.7", "2", "2", "0", "500", "0", "80", "2", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.7", "98.2", "", "", "", "", "96.2"]} +{"pcdb_id": 17204, "brand_name": "Rotex", "model_name": "GCU Compact 533", "model_qualifier": "", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 82.2, "comparative_hot_water_efficiency_pct": 38.4, "output_kw_max": 29.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017204", "000246", "0", "2024/Jan/31 10:17", "Rotex Heating Systems", "Rotex", "GCU Compact 533", "", "", "2013", "current", "2", "1", "1", "2", "0", "", "", "2", "3", "2", "29", "29", "", "", "88.9", "82.2", "", "38.4", "", "2", "1", "", "106", "1", "2", "114", "6.7", "2", "2", "0", "500", "0", "80", "2", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.7", "98.9", "", "", "", "", "97.2"]} +{"pcdb_id": 17205, "brand_name": "Rotex", "model_name": "GCU Compact 533 BIV", "model_qualifier": "", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 82.2, "comparative_hot_water_efficiency_pct": 38.4, "output_kw_max": 29.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017205", "000246", "0", "2024/Jan/31 10:17", "Rotex Heating Systems", "Rotex", "GCU Compact 533 BIV", "", "", "2013", "current", "2", "1", "1", "2", "0", "", "", "2", "3", "2", "29", "29", "", "", "88.9", "82.2", "", "38.4", "", "2", "1", "", "106", "1", "2", "114", "6.7", "2", "2", "0", "500", "0", "80", "2", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.7", "98.9", "", "", "", "", "97.2"]} +{"pcdb_id": 17206, "brand_name": "Ferroli", "model_name": "T-One", "model_qualifier": "30C HE", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 86.8, "comparative_hot_water_efficiency_pct": 74.6, "output_kw_max": 29.5, "final_year_of_manufacture": 2017, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0004, "loss_factor_f1_kwh_per_day": 0.95759, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017206", "000097", "0", "2017/Aug/07 17:02", "Ferroli", "Ferroli", "T-One", "30C HE", "", "2013", "2017", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "29.5", "29.5", "", "", "88.6", "86.8", "", "74.6", "", "2", "", "", "104", "1", "2", "100", "", "0", "", "", "", "0", "", "", "", "", "1", "7.0627", "0.07685", "0.0004", "0.95759", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.4", "98.1", "", "", "", "", "96.3"]} +{"pcdb_id": 17211, "brand_name": "Morco", "model_name": "GB30", "model_qualifier": "", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 63.0, "output_kw_max": 24.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017211", "000282", "0", "2013/Nov/29 09:25", "Morco Products Ltd", "Morco", "GB30", "", "", "2013", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "89.4", "80.8", "", "63.0", "", "2", "1", "", "104", "1", "2", "152", "1", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "", "0035", "", "", "", "", "", "", "", "", "92.0", "99.0", "", "", "", "", "97.7"]} +{"pcdb_id": 17212, "brand_name": "Morco", "model_name": "GB24-NG", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 62.2, "output_kw_max": 24.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017212", "000282", "0", "2013/Nov/29 09:25", "Morco Products Ltd", "Morco", "GB24-NG", "", "", "2013", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "88.3", "79.7", "", "62.2", "", "2", "", "", "104", "1", "2", "146", "1", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "", "0035", "", "", "", "", "", "", "", "", "89.8", "96.9", "", "", "", "", "95.5"]} +{"pcdb_id": 17213, "brand_name": "Morco", "model_name": "GB24", "model_qualifier": "", "winter_efficiency_pct": 89.3, "summer_efficiency_pct": 80.7, "comparative_hot_water_efficiency_pct": 63.0, "output_kw_max": 24.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017213", "000282", "0", "2013/Nov/29 09:25", "Morco Products Ltd", "Morco", "GB24", "", "", "2013", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "89.3", "80.7", "", "63.0", "", "2", "1", "", "104", "1", "2", "146", "1", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "", "0035", "", "", "", "", "", "", "", "", "91.8", "99.0", "", "", "", "", "97.6"]} +{"pcdb_id": 17214, "brand_name": "Morco", "model_name": "GB30-NG", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 62.3, "output_kw_max": 24.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017214", "000282", "0", "2013/Nov/29 09:25", "Morco Products Ltd", "Morco", "GB30-NG", "", "", "2013", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "88.4", "79.8", "", "62.3", "", "2", "", "", "104", "1", "2", "152", "1", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "", "0035", "", "", "", "", "", "", "", "", "90.0", "96.9", "", "", "", "", "95.6"]} +{"pcdb_id": 17215, "brand_name": "Vokera", "model_name": "Excel", "model_qualifier": "29", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 86.7, "comparative_hot_water_efficiency_pct": 71.9, "output_kw_max": 24.45, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.003, "loss_factor_f1_kwh_per_day": 1.18793, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017215", "000011", "0", "2015/Mar/04 16:44", "Vokera", "Vokera", "Excel", "29", "47 364 13", "2013", "current", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "24.45", "24.45", "", "", "88.4", "86.7", "", "71.9", "", "2", "", "", "104", "1", "2", "110", "4.5", "0", "", "", "", "0", "", "", "", "", "1", "7.325", "0.103", "0.003", "1.18793", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "", "", "", "", "88.1", "97.7", "", "", "", "", "95.9"]} +{"pcdb_id": 17216, "brand_name": "Vokera", "model_name": "Excel", "model_qualifier": "25", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 86.6, "comparative_hot_water_efficiency_pct": 72.0, "output_kw_max": 19.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.003, "loss_factor_f1_kwh_per_day": 1.17113, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017216", "000011", "0", "2015/Mar/04 16:44", "Vokera", "Vokera", "Excel", "25", "47 364 12", "2013", "current", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "19.5", "19.5", "", "", "88.5", "86.6", "", "72.0", "", "2", "", "", "104", "1", "2", "110", "4.5", "0", "", "", "", "0", "", "", "", "", "1", "7.315", "0.105", "0.003", "1.17113", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "", "", "", "", "87.8", "98.1", "", "", "", "", "96.2"]} +{"pcdb_id": 17217, "brand_name": "Ferroli", "model_name": "T-One", "model_qualifier": "25C HE", "winter_efficiency_pct": 89.6, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 56.9, "output_kw_max": 24.5, "final_year_of_manufacture": 2017, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017217", "000097", "0", "2017/Aug/21 13:41", "Ferroli", "Ferroli", "T-One", "25C HE", "", "2013", "2017", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24.5", "24.5", "", "", "89.6", "81.0", "", "56.9", "", "2", "1", "", "104", "1", "2", "100", "3.2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.4", "100.2", "", "", "", "", "98.3"]} +{"pcdb_id": 17218, "brand_name": "Sabre", "model_name": "25 HE Plus", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 56.1, "output_kw_max": 19.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017218", "000011", "0", "2013/Dec/12 12:24", "Vokera", "Sabre", "25 HE Plus", "", "47 364 08", "2010", "current", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "19.5", "19.5", "", "", "88.4", "79.8", "", "56.1", "", "2", "", "", "104", "1", "2", "123", "4.5", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "97.8", "", "", "", "", "95.9"]} +{"pcdb_id": 17219, "brand_name": "Sabre", "model_name": "29 HE Plus", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 56.0, "output_kw_max": 24.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017219", "000011", "0", "2013/Dec/12 12:24", "Vokera", "Sabre", "29 HE Plus", "", "47 364 09", "2010", "current", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "24.4", "24.4", "", "", "88.3", "79.7", "", "56.0", "", "2", "", "", "104", "1", "2", "140", "4.5", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "97.6", "", "", "", "", "95.7"]} +{"pcdb_id": 17220, "brand_name": "Potterton", "model_name": "Profile", "model_qualifier": "18HO", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 17.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017220", "000005", "0", "2014/Jan/27 10:41", "Baxi Heating UK", "Potterton", "Profile", "18HO", "", "2014", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "17.6", "17.6", "", "", "88.5", "79.5", "", "58.1", "", "2", "", "", "102", "1", "2", "50", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.6", "97.9", "", "", "", "", "96.2"]} +{"pcdb_id": 17221, "brand_name": "Potterton", "model_name": "Profile", "model_qualifier": "18HO", "winter_efficiency_pct": 89.6, "summer_efficiency_pct": 80.6, "comparative_hot_water_efficiency_pct": 58.8, "output_kw_max": 17.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017221", "000005", "0", "2014/Jan/27 10:42", "Baxi Heating UK", "Potterton", "Profile", "18HO", "", "2014", "current", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "17.6", "17.6", "", "", "89.6", "80.6", "", "58.8", "", "2", "1", "", "102", "1", "2", "50", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.5", "100.1", "", "", "", "", "98.3"]} +{"pcdb_id": 17222, "brand_name": "Potterton", "model_name": "Profile", "model_qualifier": "24HO", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 24.7, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017222", "000005", "0", "2014/Jan/27 10:42", "Baxi Heating UK", "Potterton", "Profile", "24HO", "", "2014", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "24.7", "24.7", "", "", "88.9", "79.9", "", "58.4", "", "2", "", "", "102", "1", "2", "50", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.5", "98.8", "", "", "", "", "96.9"]} +{"pcdb_id": 17223, "brand_name": "Potterton", "model_name": "Profile", "model_qualifier": "24HO", "winter_efficiency_pct": 89.9, "summer_efficiency_pct": 80.9, "comparative_hot_water_efficiency_pct": 59.1, "output_kw_max": 24.7, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017223", "000005", "0", "2014/Jan/27 10:42", "Baxi Heating UK", "Potterton", "Profile", "24HO", "", "2014", "current", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "24.7", "24.7", "", "", "89.9", "80.9", "", "59.1", "", "2", "1", "", "102", "1", "2", "50", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.4", "101.0", "", "", "", "", "99.0"]} +{"pcdb_id": 17224, "brand_name": "Potterton", "model_name": "Profile", "model_qualifier": "30HO", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 29.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017224", "000005", "0", "2014/Jan/27 10:42", "Baxi Heating UK", "Potterton", "Profile", "30HO", "", "2014", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "29.4", "29.4", "", "", "88.9", "79.9", "", "58.4", "", "2", "", "", "102", "1", "2", "115", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.5", "98.8", "", "", "", "", "96.9"]} +{"pcdb_id": 17225, "brand_name": "Potterton", "model_name": "Profile", "model_qualifier": "30HO", "winter_efficiency_pct": 89.9, "summer_efficiency_pct": 80.9, "comparative_hot_water_efficiency_pct": 59.1, "output_kw_max": 29.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017225", "000005", "0", "2014/Jan/27 10:42", "Baxi Heating UK", "Potterton", "Profile", "30HO", "", "2014", "current", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "29.4", "29.4", "", "", "89.9", "80.9", "", "59.1", "", "2", "1", "", "102", "1", "2", "115", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.4", "101.0", "", "", "", "", "99.0"]} +{"pcdb_id": 17226, "brand_name": "Potterton", "model_name": "Profile", "model_qualifier": "18S", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 17.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017226", "000005", "0", "2014/Jan/27 10:42", "Baxi Heating UK", "Potterton", "Profile", "18S", "", "2014", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "17.6", "17.6", "", "", "88.5", "79.5", "", "58.1", "", "2", "", "", "102", "1", "2", "115", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.6", "97.9", "", "", "", "", "96.2"]} +{"pcdb_id": 17227, "brand_name": "Potterton", "model_name": "Profile", "model_qualifier": "18S", "winter_efficiency_pct": 89.6, "summer_efficiency_pct": 80.6, "comparative_hot_water_efficiency_pct": 58.8, "output_kw_max": 17.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017227", "000005", "0", "2014/Jan/27 10:42", "Baxi Heating UK", "Potterton", "Profile", "18S", "", "2014", "current", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "17.6", "17.6", "", "", "89.6", "80.6", "", "58.8", "", "2", "1", "", "102", "1", "2", "115", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.5", "100.1", "", "", "", "", "98.3"]} +{"pcdb_id": 17228, "brand_name": "Potterton", "model_name": "Profile", "model_qualifier": "24S", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 21.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017228", "000005", "0", "2014/Jan/27 10:42", "Baxi Heating UK", "Potterton", "Profile", "24S", "", "2014", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "21.6", "21.6", "", "", "88.5", "79.5", "", "58.1", "", "2", "", "", "102", "1", "2", "115", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.6", "97.9", "", "", "", "", "96.2"]} +{"pcdb_id": 17229, "brand_name": "Potterton", "model_name": "Profile", "model_qualifier": "24s", "winter_efficiency_pct": 89.6, "summer_efficiency_pct": 80.6, "comparative_hot_water_efficiency_pct": 58.8, "output_kw_max": 21.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017229", "000005", "0", "2014/Feb/24 11:09", "Baxi Heating UK", "Potterton", "Profile", "24s", "", "2014", "current", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "21.6", "21.6", "", "", "89.6", "80.6", "", "58.8", "", "2", "1", "", "102", "1", "2", "115", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.5", "100.1", "", "", "", "", "98.3"]} +{"pcdb_id": 17230, "brand_name": "Potterton", "model_name": "Profile", "model_qualifier": "30S", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 29.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017230", "000005", "0", "2014/Jan/27 10:43", "Baxi Heating UK", "Potterton", "Profile", "30S", "", "2013", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "29.4", "29.4", "", "", "88.9", "79.9", "", "58.4", "", "2", "", "", "102", "1", "2", "150", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.5", "98.8", "", "", "", "", "96.9"]} +{"pcdb_id": 17231, "brand_name": "Potterton", "model_name": "Profile", "model_qualifier": "30S", "winter_efficiency_pct": 89.9, "summer_efficiency_pct": 80.9, "comparative_hot_water_efficiency_pct": 59.1, "output_kw_max": 29.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017231", "000005", "0", "2014/Jan/27 10:43", "Baxi Heating UK", "Potterton", "Profile", "30S", "", "2013", "current", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "29.4", "29.4", "", "", "89.9", "80.9", "", "59.1", "", "2", "1", "", "102", "1", "2", "150", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.4", "101.0", "", "", "", "", "99.0"]} +{"pcdb_id": 17232, "brand_name": "Vokera", "model_name": "Compact", "model_qualifier": "25A", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 86.6, "comparative_hot_water_efficiency_pct": 72.0, "output_kw_max": 19.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.003, "loss_factor_f1_kwh_per_day": 1.17113, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017232", "000011", "0", "2015/Mar/04 16:46", "Vokera", "Vokera", "Compact", "25A", "47 364 17", "2013", "current", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "19.5", "19.5", "", "", "88.5", "86.6", "", "72.0", "", "2", "", "", "104", "1", "2", "123", "4.5", "0", "", "", "", "0", "", "", "", "", "1", "7.315", "0.105", "0.003", "1.17113", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "", "", "", "", "87.8", "98.1", "", "", "", "", "96.2"]} +{"pcdb_id": 17233, "brand_name": "Vokera", "model_name": "Compact", "model_qualifier": "29A", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 86.7, "comparative_hot_water_efficiency_pct": 71.9, "output_kw_max": 24.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.003, "loss_factor_f1_kwh_per_day": 1.18793, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017233", "000011", "0", "2015/Mar/04 16:46", "Vokera", "Vokera", "Compact", "29A", "47 364 18", "2013", "current", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "24.5", "24.5", "", "", "88.4", "86.7", "", "71.9", "", "2", "", "", "104", "1", "2", "123", "4.5", "0", "", "", "", "0", "", "", "", "", "1", "7.325", "0.103", "0.003", "1.18793", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "", "", "", "", "88.1", "97.7", "", "", "", "", "95.9"]} +{"pcdb_id": 17234, "brand_name": "Ferroli", "model_name": "T-One", "model_qualifier": "30C HE", "winter_efficiency_pct": 89.6, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 57.0, "output_kw_max": 28.9, "final_year_of_manufacture": 2017, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017234", "000097", "0", "2017/Aug/21 13:41", "Ferroli", "Ferroli", "T-One", "30C HE", "", "2013", "2017", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "28.9", "28.9", "", "", "89.6", "81.0", "", "57.0", "", "2", "1", "", "104", "1", "2", "100", "3.2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.4", "100.3", "", "", "", "", "98.4"]} +{"pcdb_id": 17236, "brand_name": "Motan", "model_name": "MKDens 25", "model_qualifier": "", "winter_efficiency_pct": 87.6, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 55.6, "output_kw_max": 24.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017236", "000283", "0", "2014/Jan/31 11:39", "Kober", "Motan", "MKDens 25", "", "", "2012", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.3", "24.3", "", "", "87.6", "79.0", "", "55.6", "", "2", "", "", "104", "1", "2", "175", "0", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.1", "96.1", "", "", "", "", "94.4"]} +{"pcdb_id": 17238, "brand_name": "Motan", "model_name": "MKDens 36", "model_qualifier": "", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 55.7, "output_kw_max": 32.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017238", "000283", "0", "2014/Jan/31 11:39", "Kober", "Motan", "MKDens 36", "", "", "2012", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "32.3", "32.3", "", "", "87.9", "79.3", "", "55.7", "", "2", "", "", "104", "1", "2", "175", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.2", "96.0", "", "", "", "", "94.7"]} +{"pcdb_id": 17239, "brand_name": "Mistral", "model_name": "DKUT 17/33", "model_qualifier": "", "winter_efficiency_pct": 86.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 54.8, "output_kw_max": 33.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017239", "000056", "0", "2014/Apr/23 14:08", "Mistral Energy Products Ltd", "Mistral", "DKUT 17/33", "", "", "2013", "current", "4", "1", "1", "1", "0", "", "", "1", "3", "1", "17", "33", "", "", "86.7", "75.0", "", "54.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "87.4", "89.2", "", "", "", "", "88.9"]} +{"pcdb_id": 17240, "brand_name": "Hoval", "model_name": "TopGas (30)", "model_qualifier": "", "winter_efficiency_pct": 87.5, "summer_efficiency_pct": 78.5, "comparative_hot_water_efficiency_pct": 57.3, "output_kw_max": 27.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017240", "000284", "0", "2014/Apr/29 14:07", "Hoval", "Hoval", "TopGas (30)", "", "", "", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "27.4", "27.4", "", "", "87.5", "78.5", "", "57.3", "", "2", "", "", "102", "1", "2", "43", "13", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.3", "95.8", "", "", "", "", "94.2"]} +{"pcdb_id": 17241, "brand_name": "Hoval", "model_name": "TopGas (35)", "model_qualifier": "", "winter_efficiency_pct": 87.3, "summer_efficiency_pct": 78.3, "comparative_hot_water_efficiency_pct": 57.2, "output_kw_max": 31.8, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017241", "000284", "0", "2014/Apr/29 14:07", "Hoval", "Hoval", "TopGas (35)", "", "", "", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "31.8", "31.8", "", "", "87.3", "78.3", "", "57.2", "", "2", "", "", "102", "1", "2", "62", "13", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "86.9", "95.6", "", "", "", "", "93.9"]} +{"pcdb_id": 17242, "brand_name": "Hoval", "model_name": "TopGas (45)", "model_qualifier": "", "winter_efficiency_pct": 87.3, "summer_efficiency_pct": 78.3, "comparative_hot_water_efficiency_pct": 57.2, "output_kw_max": 41.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017242", "000284", "0", "2014/Apr/29 14:07", "Hoval", "Hoval", "TopGas (45)", "", "", "", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "41.0", "41.0", "", "", "87.3", "78.3", "", "57.2", "", "2", "", "", "102", "1", "2", "66", "13", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "86.9", "95.4", "", "", "", "", "93.8"]} +{"pcdb_id": 17243, "brand_name": "Hoval", "model_name": "TopGas (60)", "model_qualifier": "", "winter_efficiency_pct": 87.3, "summer_efficiency_pct": 78.3, "comparative_hot_water_efficiency_pct": 57.2, "output_kw_max": 55.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017243", "000284", "0", "2014/Apr/29 14:07", "Hoval", "Hoval", "TopGas (60)", "", "", "", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "55.3", "55.3", "", "", "87.3", "78.3", "", "57.2", "", "2", "", "", "102", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "86.9", "95.4", "", "", "", "", "93.8"]} +{"pcdb_id": 17244, "brand_name": "Glow-worm", "model_name": "Glow-Worm", "model_qualifier": "18si", "winter_efficiency_pct": 77.7, "summer_efficiency_pct": 67.6, "comparative_hot_water_efficiency_pct": 49.4, "output_kw_max": 18.4, "final_year_of_manufacture": 2007, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017244", "000207", "0", "2014/Apr/16 08:09", "Hepworth Heating", "Glow-worm", "Glow-Worm", "18si", "41-047-61", "2001", "2007", "1", "1", "1", "1", "0", "", "", "1", "2", "1", "8.9", "18.4", "", "", "77.7", "67.6", "", "49.4", "", "2", "", "", "101", "1", "1", "122", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0002", "", "", "", "", "", "", "", "", "81.5", "77.2", "", "", "", "", "78.0"]} +{"pcdb_id": 17245, "brand_name": "Ideal", "model_name": "Classic", "model_qualifier": "30", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 62.3, "output_kw_max": 24.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017245", "000008", "0", "2014/Apr/28 09:04", "Ideal Boilers", "Ideal", "Classic", "30", "47-349-08", "2014", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "88.4", "79.8", "", "62.3", "", "2", "", "", "104", "1", "2", "152", "1", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "", "0035", "", "", "", "", "", "", "", "", "90.0", "96.9", "", "", "", "", "95.6"]} +{"pcdb_id": 17246, "brand_name": "Ideal", "model_name": "Classic", "model_qualifier": "24", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 62.2, "output_kw_max": 24.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017246", "000008", "0", "2014/Apr/28 09:05", "Ideal Boilers", "Ideal", "Classic", "24", "47-349-07", "2014", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "88.3", "79.7", "", "62.2", "", "2", "", "", "104", "1", "2", "146", "1", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "", "0035", "", "", "", "", "", "", "", "", "89.8", "96.9", "", "", "", "", "95.5"]} +{"pcdb_id": 17247, "brand_name": "Vokera", "model_name": "Mynute", "model_qualifier": "i20", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 21.44, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017247", "000011", "0", "2014/Jul/17 12:28", "Vokera", "Vokera", "Mynute", "i20", "41 094 81", "2013", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "21.44", "21.44", "", "", "88.8", "79.8", "", "58.3", "", "2", "", "", "102", "1", "2", "102", "4.5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "88.4", "98.7", "", "", "", "", "96.8"]} +{"pcdb_id": 17248, "brand_name": "Vokera", "model_name": "Mynute", "model_qualifier": "i30", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 31.77, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017248", "000011", "0", "2015/Mar/04 16:16", "Vokera", "Vokera", "Mynute", "i30", "41 094 82", "2014", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "31.77", "31.77", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "118", "4.5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "97.8", "", "", "", "", "95.9"]} +{"pcdb_id": 17249, "brand_name": "ROC", "model_name": "LJLGB26-B28CV", "model_qualifier": "", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.4, "comparative_hot_water_efficiency_pct": 56.6, "output_kw_max": 28.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017249", "000285", "0", "2014/Nov/14 10:16", "Guangdong ROC Cool and Heat Equipment Co Ltd", "ROC", "LJLGB26-B28CV", "", "", "2013", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28", "28", "", "", "89.0", "80.4", "", "56.6", "", "2", "", "", "104", "1", "2", "110", "1", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.0", "99.0", "", "", "", "", "97.1"]} +{"pcdb_id": 17250, "brand_name": "ROC", "model_name": "LJLGB26-B28CP", "model_qualifier": "", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.4, "comparative_hot_water_efficiency_pct": 56.6, "output_kw_max": 28.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017250", "000285", "0", "2014/Nov/14 10:16", "Guangdong ROC Cool and Heat Equipment Co Ltd", "ROC", "LJLGB26-B28CP", "", "", "2014", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28", "28", "", "", "89.0", "80.4", "", "56.6", "", "2", "", "", "104", "1", "2", "110", "1", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.0", "99.0", "", "", "", "", "97.1"]} +{"pcdb_id": 17251, "brand_name": "The White Boiler Company", "model_name": "WH 80 (T)", "model_qualifier": "", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 56.4, "output_kw_max": 19.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017251", "000270", "0", "2014/Sep/10 12:09", "The White Boiler Company", "The White Boiler Company", "WH 80 (T)", "", "", "2014", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "19.4", "19.4", "", "", "88.9", "80.3", "", "56.4", "", "2", "1", "", "104", "1", "2", "110", "3", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.8", "98.6", "", "", "", "", "97.0"]} +{"pcdb_id": 17252, "brand_name": "The White Boiler Company", "model_name": "WH 80 (T)", "model_qualifier": "", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 86.6, "comparative_hot_water_efficiency_pct": 76.8, "output_kw_max": 19.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0104, "loss_factor_f1_kwh_per_day": 0.68941, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017252", "000270", "0", "2014/Sep/10 12:10", "The White Boiler Company", "The White Boiler Company", "WH 80 (T)", "", "", "2014", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "19.5", "19.5", "", "", "87.9", "86.6", "", "76.8", "", "2", "", "", "104", "1", "2", "110", "3", "0", "", "", "", "0", "", "", "", "", "1", "6.859", "0.134", "0.0104", "0.68941", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "96.5", "", "", "", "", "94.9"]} +{"pcdb_id": 17253, "brand_name": "The White Boiler Company", "model_name": "WH 90 (T)", "model_qualifier": "", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 56.6, "output_kw_max": 23.8, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017253", "000270", "0", "2014/Sep/10 12:10", "The White Boiler Company", "The White Boiler Company", "WH 90 (T)", "", "", "2014", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "23.8", "23.8", "", "", "89.1", "80.5", "", "56.6", "", "2", "1", "", "104", "1", "2", "160", "3", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.8", "99.3", "", "", "", "", "97.5"]} +{"pcdb_id": 17254, "brand_name": "The White Boiler Company", "model_name": "WH 90 (T)", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 86.6, "comparative_hot_water_efficiency_pct": 69.1, "output_kw_max": 23.8, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0065, "loss_factor_f1_kwh_per_day": 1.44231, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017254", "000270", "0", "2014/Sep/10 12:10", "The White Boiler Company", "The White Boiler Company", "WH 90 (T)", "", "", "2014", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "23.8", "23.8", "", "", "88.1", "86.6", "", "69.1", "", "2", "", "", "104", "1", "2", "160", "3", "0", "", "", "", "0", "", "", "", "", "1", "7.618", "0.129", "0.0065", "1.44231", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "97.1", "", "", "", "", "95.4"]} +{"pcdb_id": 17267, "brand_name": "Firebird", "model_name": "Blue Flame Enviromax Heatpac", "model_qualifier": "26kW", "winter_efficiency_pct": 89.7, "summer_efficiency_pct": 81.9, "comparative_hot_water_efficiency_pct": 59.8, "output_kw_max": 26.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017267", "000047", "0", "2014/Jun/30 08:57", "Firebird Boilers", "Firebird", "Blue Flame Enviromax Heatpac", "26kW", "", "2014", "current", "4", "1", "2", "1", "0", "", "", "2", "2", "1", "26", "26", "", "", "89.7", "81.9", "", "59.8", "", "2", "", "", "201", "1", "1", "38", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "94.2", "97.6", "", "", "", "", "97.0"]} +{"pcdb_id": 17268, "brand_name": "Baxi", "model_name": "Ecoblue 32 System", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 32.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017268", "000005", "0", "2015/Aug/06 12:31", "Baxi Heating UK", "Baxi", "Ecoblue 32 System", "", "GC No 41-470-01", "2014", "2015", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "32", "32", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "140", "3.5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "90.0", "96.9", "", "", "", "", "95.6"]} +{"pcdb_id": 17269, "brand_name": "Baxi", "model_name": "Ecoblue 28 System", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 28.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017269", "000005", "0", "2015/Aug/06 12:32", "Baxi Heating UK", "Baxi", "Ecoblue 28 System", "", "GC No 41-077-99", "2014", "2015", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "28", "28", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "137", "3.5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "90.0", "96.9", "", "", "", "", "95.6"]} +{"pcdb_id": 17270, "brand_name": "Baxi", "model_name": "Ecoblue 24 System", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 24.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017270", "000005", "0", "2015/Aug/06 12:32", "Baxi Heating UK", "Baxi", "Ecoblue 24 System", "", "GC No 41-077-98", "2014", "2015", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24", "24", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "123", "3.5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "90.0", "96.9", "", "", "", "", "95.6"]} +{"pcdb_id": 17271, "brand_name": "Baxi", "model_name": "Ecoblue 18 System", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 18.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017271", "000005", "0", "2015/Aug/06 12:33", "Baxi Heating UK", "Baxi", "Ecoblue 18 System", "", "GC No 41-077-97", "2014", "2015", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18", "18", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "125", "3.5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "90.0", "97.0", "", "", "", "", "95.7"]} +{"pcdb_id": 17272, "brand_name": "Baxi", "model_name": "Ecoblue 15 System", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 15.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017272", "000005", "0", "2015/Aug/06 12:33", "Baxi Heating UK", "Baxi", "Ecoblue 15 System", "", "GC No 41-077-96", "2014", "2015", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "15", "15", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "108", "3.5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "90.0", "97.0", "", "", "", "", "95.7"]} +{"pcdb_id": 17273, "brand_name": "Baxi", "model_name": "Ecoblue 12 System", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 12.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017273", "000005", "0", "2015/Aug/06 12:34", "Baxi Heating UK", "Baxi", "Ecoblue 12 System", "", "GC No 41-077-95", "2014", "2015", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "12", "12", "", "", "88.5", "79.5", "", "58.0", "", "2", "", "", "102", "1", "2", "108", "3.5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "90.0", "97.1", "", "", "", "", "95.8"]} +{"pcdb_id": 17274, "brand_name": "Baxi", "model_name": "Ecoblue Plus 33 Combi", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 77.2, "output_kw_max": 28.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0045, "loss_factor_f1_kwh_per_day": 0.74098, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017274", "000005", "0", "2015/Aug/06 12:34", "Baxi Heating UK", "Baxi", "Ecoblue Plus 33 Combi", "", "GC No 41-075-86", "2014", "2015", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28", "28", "", "", "88.4", "87.3", "", "77.2", "", "2", "", "", "104", "1", "2", "135", "3.5", "0", "", "", "", "0", "", "", "", "", "1", "6.821", "0.106", "0.0045", "0.74098", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "90.0", "97.0", "", "", "", "", "95.7"]} +{"pcdb_id": 17275, "brand_name": "Baxi", "model_name": "Ecoblue Plus 28 Combi", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 77.3, "output_kw_max": 24.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0044, "loss_factor_f1_kwh_per_day": 0.73349, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017275", "000005", "0", "2015/Aug/06 12:34", "Baxi Heating UK", "Baxi", "Ecoblue Plus 28 Combi", "", "GC No 41-077-85", "2014", "2015", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "88.4", "87.3", "", "77.3", "", "2", "", "", "104", "1", "2", "130", "3.5", "0", "", "", "", "0", "", "", "", "", "1", "6.813", "0.118", "0.0044", "0.73349", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "90.0", "96.9", "", "", "", "", "95.6"]} +{"pcdb_id": 17276, "brand_name": "Baxi", "model_name": "Ecoblue Plus 24 Combi", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 77.6, "output_kw_max": 20.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0043, "loss_factor_f1_kwh_per_day": 0.70793, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017276", "000005", "0", "2015/Aug/06 12:35", "Baxi Heating UK", "Baxi", "Ecoblue Plus 24 Combi", "", "GC No 41-075-84", "2014", "2015", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "20", "20", "", "", "88.4", "87.3", "", "77.6", "", "2", "", "", "104", "1", "2", "120", "3.5", "0", "", "", "", "0", "", "", "", "", "1", "6.786", "0.118", "0.0043", "0.70793", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "90.0", "96.9", "", "", "", "", "95.6"]} +{"pcdb_id": 17277, "brand_name": "Baxi", "model_name": "Ecoblue 33 Combi", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 77.2, "output_kw_max": 28.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0045, "loss_factor_f1_kwh_per_day": 0.74098, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017277", "000005", "0", "2015/Aug/06 12:36", "Baxi Heating UK", "Baxi", "Ecoblue 33 Combi", "", "GC No 41-075-83", "2014", "2015", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28", "28", "", "", "88.4", "87.3", "", "77.2", "", "2", "", "", "104", "1", "2", "135", "3.5", "0", "", "", "", "0", "", "", "", "", "1", "6.821", "0.106", "0.0045", "0.74098", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "90.0", "97.0", "", "", "", "", "95.7"]} +{"pcdb_id": 17278, "brand_name": "Baxi", "model_name": "Ecoblue 28 Combi", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 77.3, "output_kw_max": 24.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0044, "loss_factor_f1_kwh_per_day": 0.73349, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017278", "000005", "0", "2015/Aug/06 12:36", "Baxi Heating UK", "Baxi", "Ecoblue 28 Combi", "", "GC No 41-075-82", "2014", "2015", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "88.4", "87.3", "", "77.3", "", "2", "", "", "104", "1", "2", "130", "3.5", "0", "", "", "", "0", "", "", "", "", "1", "6.813", "0.118", "0.0044", "0.73349", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "90.0", "96.9", "", "", "", "", "95.6"]} +{"pcdb_id": 17279, "brand_name": "Baxi", "model_name": "Ecoblue 24 Combi", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 77.6, "output_kw_max": 20.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0043, "loss_factor_f1_kwh_per_day": 0.70793, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017279", "000005", "0", "2015/Aug/06 12:37", "Baxi Heating UK", "Baxi", "Ecoblue 24 Combi", "", "GC No 41-075-81", "2014", "2015", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "20", "20", "", "", "88.4", "87.3", "", "77.6", "", "2", "", "", "104", "1", "2", "120", "3.5", "0", "", "", "", "0", "", "", "", "", "1", "6.786", "0.118", "0.0043", "0.70793", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "90.0", "96.9", "", "", "", "", "95.6"]} +{"pcdb_id": 17280, "brand_name": "Baxi", "model_name": "Ecoblue Advance 33 Combi ERP", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 77.2, "output_kw_max": 28.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0045, "loss_factor_f1_kwh_per_day": 0.74098, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017280", "000005", "0", "2015/Aug/06 12:37", "Baxi Heating UK", "Baxi", "Ecoblue Advance 33 Combi ERP", "", "GC No 41-075-92", "2014", "2015", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28", "28", "", "", "88.4", "87.3", "", "77.2", "", "2", "", "", "104", "1", "2", "135", "3.5", "0", "", "", "", "0", "", "", "", "", "1", "6.821", "0.106", "0.0045", "0.74098", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "90.0", "97.0", "", "", "", "", "95.7"]} +{"pcdb_id": 17281, "brand_name": "Baxi", "model_name": "Ecoblue Advance 28 Combi ERP", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 77.3, "output_kw_max": 24.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0044, "loss_factor_f1_kwh_per_day": 0.73349, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017281", "000005", "0", "2015/Aug/06 12:38", "Baxi Heating UK", "Baxi", "Ecoblue Advance 28 Combi ERP", "", "GC No 41-075-91", "2014", "2015", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "88.4", "87.3", "", "77.3", "", "2", "", "", "104", "1", "2", "130", "3.5", "0", "", "", "", "0", "", "", "", "", "1", "6.813", "0.118", "0.0044", "0.73349", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "90.0", "96.9", "", "", "", "", "95.6"]} +{"pcdb_id": 17282, "brand_name": "Baxi", "model_name": "Ecoblue Advance 40 Combi", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 77.8, "output_kw_max": 32.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0036, "loss_factor_f1_kwh_per_day": 0.69163, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017282", "000005", "0", "2015/Aug/06 12:38", "Baxi Heating UK", "Baxi", "Ecoblue Advance 40 Combi", "", "GC No 41-075-90", "2014", "2015", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "32", "32", "", "", "88.4", "87.3", "", "77.8", "", "2", "", "", "104", "1", "2", "175", "3.5", "0", "", "", "", "0", "", "", "", "", "1", "6.765", "0.111", "0.0036", "0.69163", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.0", "96.9", "", "", "", "", "95.6"]} +{"pcdb_id": 17283, "brand_name": "Baxi", "model_name": "Ecoblue Advance 33 Combi", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 77.2, "output_kw_max": 28.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0045, "loss_factor_f1_kwh_per_day": 0.74098, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017283", "000005", "0", "2015/Aug/06 12:40", "Baxi Heating UK", "Baxi", "Ecoblue Advance 33 Combi", "", "GC No 41-075-89", "2014", "2015", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28", "28", "", "", "88.4", "87.3", "", "77.2", "", "2", "", "", "104", "1", "2", "135", "3.5", "0", "", "", "", "0", "", "", "", "", "1", "6.821", "0.106", "0.0045", "0.74098", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "90.0", "97.0", "", "", "", "", "95.7"]} +{"pcdb_id": 17284, "brand_name": "Baxi", "model_name": "Ecoblue Advance 28 Combi", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 77.3, "output_kw_max": 24.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0044, "loss_factor_f1_kwh_per_day": 0.73349, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017284", "000005", "0", "2015/Aug/06 12:40", "Baxi Heating UK", "Baxi", "Ecoblue Advance 28 Combi", "", "GC No 41-075-88", "2014", "2015", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "88.4", "87.3", "", "77.3", "", "2", "", "", "104", "1", "2", "130", "3.5", "0", "", "", "", "0", "", "", "", "", "1", "6.813", "0.118", "0.0044", "0.73349", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "90.0", "96.9", "", "", "", "", "95.6"]} +{"pcdb_id": 17285, "brand_name": "Baxi", "model_name": "Ecoblue Advance 24 Combi", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 77.6, "output_kw_max": 20.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0043, "loss_factor_f1_kwh_per_day": 0.70793, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017285", "000005", "0", "2015/Aug/06 12:40", "Baxi Heating UK", "Baxi", "Ecoblue Advance 24 Combi", "", "GC No 41-075-87", "2014", "2015", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "20", "20", "", "", "88.4", "87.3", "", "77.6", "", "2", "", "", "104", "1", "2", "120", "3.5", "0", "", "", "", "0", "", "", "", "", "1", "6.786", "0.118", "0.0043", "0.70793", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "90.0", "96.9", "", "", "", "", "95.6"]} +{"pcdb_id": 17286, "brand_name": "Firebird", "model_name": "Enviromax Blue Supreme Popular 26", "model_qualifier": "", "winter_efficiency_pct": 90.6, "summer_efficiency_pct": 82.8, "comparative_hot_water_efficiency_pct": 60.5, "output_kw_max": 26.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017286", "000047", "0", "2015/Nov/13 11:00", "Firebird Heating Solutions Ltd", "Firebird", "Enviromax Blue Supreme Popular 26", "", "", "2014", "current", "4", "1", "2", "1", "0", "", "", "2", "2", "1", "26", "26", "", "", "90.6", "82.8", "", "60.5", "", "2", "", "", "201", "1", "1", "38", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "95.6", "101.4", "", "", "", "", "100.3"]} +{"pcdb_id": 17287, "brand_name": "Firebird", "model_name": "Enviromax Blue Supreme Utility 26", "model_qualifier": "", "winter_efficiency_pct": 90.6, "summer_efficiency_pct": 82.8, "comparative_hot_water_efficiency_pct": 60.5, "output_kw_max": 26.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017287", "000047", "0", "2015/Nov/13 11:00", "Firebird Heating Solutions Ltd", "Firebird", "Enviromax Blue Supreme Utility 26", "", "", "2014", "current", "4", "1", "1", "1", "0", "", "", "2", "2", "1", "26", "26", "", "", "90.6", "82.8", "", "60.5", "", "2", "", "", "201", "1", "1", "38", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "95.6", "101.4", "", "", "", "", "100.3"]} +{"pcdb_id": 17289, "brand_name": "Firebird", "model_name": "Enviromax Blue Supreme Heatpac 26", "model_qualifier": "", "winter_efficiency_pct": 90.6, "summer_efficiency_pct": 82.8, "comparative_hot_water_efficiency_pct": 60.5, "output_kw_max": 26.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017289", "000047", "0", "2015/Nov/13 10:59", "firebird Heating Solutions Ltd", "Firebird", "Enviromax Blue Supreme Heatpac 26", "", "", "2014", "current", "4", "1", "2", "1", "0", "", "", "2", "2", "1", "26", "26", "", "", "90.6", "82.8", "", "60.5", "", "2", "", "", "201", "1", "1", "38", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "95.6", "101.4", "", "", "", "", "100.3"]} +{"pcdb_id": 17290, "brand_name": "Firebird", "model_name": "Enviromax Blue Supreme Popular 20", "model_qualifier": "", "winter_efficiency_pct": 90.6, "summer_efficiency_pct": 82.8, "comparative_hot_water_efficiency_pct": 60.5, "output_kw_max": 20.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017290", "000047", "0", "2015/Nov/13 10:59", "firebird Heating Solutions Ltd", "Firebird", "Enviromax Blue Supreme Popular 20", "", "", "2014", "current", "4", "1", "2", "1", "0", "", "", "2", "2", "1", "20", "20", "", "", "90.6", "82.8", "", "60.5", "", "2", "", "", "201", "1", "1", "38", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "95.7", "101.3", "", "", "", "", "100.2"]} +{"pcdb_id": 17291, "brand_name": "Firebird", "model_name": "Enviromax Blue Supreme Heatpac 20", "model_qualifier": "", "winter_efficiency_pct": 90.6, "summer_efficiency_pct": 82.8, "comparative_hot_water_efficiency_pct": 60.5, "output_kw_max": 20.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017291", "000047", "0", "2015/Nov/13 10:59", "firebird Heating Solutions Ltd", "Firebird", "Enviromax Blue Supreme Heatpac 20", "", "", "2014", "current", "4", "1", "2", "1", "0", "", "", "2", "2", "1", "20", "20", "", "", "90.6", "82.8", "", "60.5", "", "2", "", "", "201", "1", "1", "38", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "95.7", "101.3", "", "", "", "", "100.2"]} +{"pcdb_id": 17292, "brand_name": "Firebird", "model_name": "Enviromax Blue Supreme Utility 20", "model_qualifier": "", "winter_efficiency_pct": 90.6, "summer_efficiency_pct": 82.8, "comparative_hot_water_efficiency_pct": 60.5, "output_kw_max": 20.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017292", "000047", "0", "2015/Nov/13 10:58", "firebird Heating Solutions Ltd", "Firebird", "Enviromax Blue Supreme Utility 20", "", "", "2014", "current", "4", "1", "1", "1", "0", "", "", "2", "2", "1", "20", "20", "", "", "90.6", "82.8", "", "60.5", "", "2", "", "", "201", "1", "1", "38", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "95.7", "101.3", "", "", "", "", "100.2"]} +{"pcdb_id": 17293, "brand_name": "Firebird", "model_name": "Enviromax Amber Supreme Popular 26", "model_qualifier": "", "winter_efficiency_pct": 90.4, "summer_efficiency_pct": 82.6, "comparative_hot_water_efficiency_pct": 60.4, "output_kw_max": 25.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017293", "000047", "0", "2015/Nov/13 10:58", "firebird Heating Solutions Ltd", "Firebird", "Enviromax Amber Supreme Popular 26", "", "", "2014", "current", "4", "1", "2", "1", "0", "", "", "2", "2", "1", "25.5", "25", "", "", "90.4", "82.6", "", "60.4", "", "2", "", "", "201", "1", "1", "38", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "94.7", "100.7", "", "", "", "", "99.6"]} +{"pcdb_id": 17294, "brand_name": "Firebird", "model_name": "Enviromax Amber Supreme Utility 26", "model_qualifier": "", "winter_efficiency_pct": 90.4, "summer_efficiency_pct": 82.6, "comparative_hot_water_efficiency_pct": 60.4, "output_kw_max": 25.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017294", "000047", "0", "2015/Nov/13 10:58", "firebird Heating Solutions Ltd", "Firebird", "Enviromax Amber Supreme Utility 26", "", "", "2014", "current", "4", "1", "1", "1", "0", "", "", "2", "2", "1", "25.5", "25.5", "", "", "90.4", "82.6", "", "60.4", "", "2", "", "", "201", "1", "1", "38", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "94.7", "100.7", "", "", "", "", "99.6"]} +{"pcdb_id": 17295, "brand_name": "Firebird", "model_name": "Enviromax Amber Supreme Heatpac 26", "model_qualifier": "", "winter_efficiency_pct": 90.4, "summer_efficiency_pct": 82.6, "comparative_hot_water_efficiency_pct": 60.4, "output_kw_max": 25.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017295", "000047", "0", "2015/Nov/13 10:57", "firebird Heating Solutions Ltd", "Firebird", "Enviromax Amber Supreme Heatpac 26", "", "", "2014", "current", "4", "1", "2", "1", "0", "", "", "2", "2", "1", "25.5", "25.5", "", "", "90.4", "82.6", "", "60.4", "", "2", "", "", "201", "1", "1", "38", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "94.7", "100.7", "", "", "", "", "99.6"]} +{"pcdb_id": 17296, "brand_name": "Baxi", "model_name": "Precision +", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 30.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017296", "000005", "0", "2015/Aug/06 12:41", "Baxi Heating UK", "Baxi", "Precision +", "", "41-470-12", "2014", "2015", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "12", "30", "", "", "88.5", "79.5", "", "58.0", "", "2", "", "", "102", "1", "2", "44", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "98.0", "", "", "", "", "96.1"]} +{"pcdb_id": 17297, "brand_name": "Baxi", "model_name": "EcoBlue Advance Heat", "model_qualifier": "30", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 30.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017297", "000005", "0", "2015/Aug/06 12:42", "Baxi Heating UK", "Baxi", "EcoBlue Advance Heat", "30", "", "2014", "2015", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "30", "30", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "44", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.5", "98.0", "", "", "", "", "96.0"]} +{"pcdb_id": 17298, "brand_name": "Baxi", "model_name": "EcoBlue Advance Heat", "model_qualifier": "25", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 25.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017298", "000005", "0", "2015/Aug/06 12:42", "Baxi Heating UK", "Baxi", "EcoBlue Advance Heat", "25", "", "2014", "2015", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "25", "25", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "33", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.7", "98.0", "", "", "", "", "96.1"]} +{"pcdb_id": 17299, "brand_name": "Baxi", "model_name": "EcoBlue Advance Heat", "model_qualifier": "19", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 19.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017299", "000005", "0", "2015/Aug/06 12:43", "Baxi Heating UK", "Baxi", "EcoBlue Advance Heat", "19", "", "2014", "2015", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "19", "19", "", "", "88.5", "79.5", "", "58.0", "", "2", "", "", "102", "1", "2", "23", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "98.0", "", "", "", "", "96.1"]} +{"pcdb_id": 17300, "brand_name": "Baxi", "model_name": "EcoBlue Advance Heat", "model_qualifier": "16", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 16.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017300", "000005", "0", "2015/Aug/06 12:43", "Baxi Heating UK", "Baxi", "EcoBlue Advance Heat", "16", "", "2014", "2015", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "16", "16", "", "", "88.5", "79.5", "", "58.1", "", "2", "", "", "102", "1", "2", "20", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "98.0", "", "", "", "", "96.1"]} +{"pcdb_id": 17301, "brand_name": "Baxi", "model_name": "EcoBlue Advance Heat", "model_qualifier": "13", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 13.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017301", "000005", "0", "2015/Aug/06 12:44", "Baxi Heating UK", "Baxi", "EcoBlue Advance Heat", "13", "41-470-07", "2014", "2015", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "13", "13", "", "", "88.5", "79.5", "", "58.1", "", "2", "", "", "102", "1", "2", "17", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "98.0", "", "", "", "", "96.1"]} +{"pcdb_id": 17302, "brand_name": "Baxi", "model_name": "EcoBlue Heat", "model_qualifier": "12", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 13.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017302", "000005", "0", "2015/Aug/06 12:44", "Baxi Heating UK", "Baxi", "EcoBlue Heat", "12", "41-470-02", "2014", "2015", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "13", "13", "", "", "88.5", "79.5", "", "58.1", "", "2", "", "", "102", "1", "2", "17", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "98.0", "", "", "", "", "96.1"]} +{"pcdb_id": 17303, "brand_name": "Baxi", "model_name": "EcoBlue Heat", "model_qualifier": "18", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 19.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017303", "000005", "0", "2015/Aug/06 12:44", "Baxi Heating UK", "Baxi", "EcoBlue Heat", "18", "", "2014", "2015", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "19", "19", "", "", "88.5", "79.5", "", "58.0", "", "2", "", "", "102", "1", "2", "23", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "98.0", "", "", "", "", "96.1"]} +{"pcdb_id": 17304, "brand_name": "Baxi", "model_name": "EcoBlue Heat", "model_qualifier": "21", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 21.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017304", "000005", "0", "2015/Aug/06 12:45", "Baxi Heating UK", "Baxi", "EcoBlue Heat", "21", "", "2014", "2015", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "21", "21", "", "", "88.5", "79.5", "", "58.0", "", "2", "", "", "102", "1", "2", "25", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "98.0", "", "", "", "", "96.1"]} +{"pcdb_id": 17305, "brand_name": "Baxi", "model_name": "EcoBlue Heat", "model_qualifier": "24", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 25.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017305", "000005", "0", "2015/Aug/06 12:45", "Baxi Heating UK", "Baxi", "EcoBlue Heat", "24", "", "2014", "2015", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "25", "25", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "33", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.7", "98.0", "", "", "", "", "96.1"]} +{"pcdb_id": 17306, "brand_name": "Baxi", "model_name": "EcoBlue Heat", "model_qualifier": "15", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 16.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017306", "000005", "0", "2015/Aug/06 12:46", "Baxi Heating UK", "Baxi", "EcoBlue Heat", "15", "", "2014", "2015", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "16", "16", "", "", "88.5", "79.5", "", "58.1", "", "2", "", "", "102", "1", "2", "20", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "98.0", "", "", "", "", "96.1"]} +{"pcdb_id": 17307, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "30", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 86.6, "comparative_hot_water_efficiency_pct": 69.2, "output_kw_max": 20.2, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0047, "loss_factor_f1_kwh_per_day": 1.44724, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017307", "000035", "0", "2020/Sep/08 10:43", "Bosch Thermotechnology", "Worcester", "Greenstar", "30", "47-406-64", "2014", "2015", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "20.2", "20.2", "", "", "88.0", "86.6", "", "69.2", "", "2", "", "", "104", "1", "2", "130", "9", "0", "", "", "", "0", "", "", "", "", "1", "7.615", "0.1348", "0.0047", "1.44724", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "96.9", "", "", "", "", "95.1"]} +{"pcdb_id": 17309, "brand_name": "Worcester", "model_name": "535 Compact NG", "model_qualifier": "", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 87.9, "comparative_hot_water_efficiency_pct": 76.5, "output_kw_max": 24.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.0015, "loss_factor_f1_kwh_per_day": 0.78638, "loss_factor_f2_kwh_per_day": 0.72553, "rejected_factor_f3_per_litre": 1e-05, "raw": ["017309", "000035", "0", "2020/Apr/09 16:20", "Bosch Thermotechnology", "Worcester", "535 Compact NG", "", "47-406-59", "2014", "2015", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "89.2", "87.9", "", "76.5", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "", "0", "", "", "", "", "2", "6.88", "0.092", "0.0015", "0.78638", "12.834", "0.114", "0.0008", "0.72553", "0.00001", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.8", "99.6", "", "", "", "", "97.5"]} +{"pcdb_id": 17310, "brand_name": "Worcester", "model_name": "533 Compact NG", "model_qualifier": "", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 88.2, "comparative_hot_water_efficiency_pct": 76.3, "output_kw_max": 24.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.0015, "loss_factor_f1_kwh_per_day": 0.80471, "loss_factor_f2_kwh_per_day": 0.76468, "rejected_factor_f3_per_litre": 1e-05, "raw": ["017310", "000035", "0", "2020/Sep/08 10:43", "Bosch Thermotechnology", "Worcester", "533 Compact NG", "", "47-406-58", "2014", "2015", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "89.2", "88.2", "", "76.3", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "", "0", "", "", "", "", "2", "6.899", "0.091", "0.0015", "0.80471", "12.831", "0.113", "0.0008", "0.76468", "0.00001", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.8", "99.6", "", "", "", "", "97.5"]} +{"pcdb_id": 17311, "brand_name": "Vokera", "model_name": "Unica", "model_qualifier": "i36", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 86.6, "comparative_hot_water_efficiency_pct": 71.3, "output_kw_max": 29.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.002, "loss_factor_f1_kwh_per_day": 1.24813, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017311", "000011", "0", "2016/Sep/21 11:27", "Vokera", "Vokera", "Unica", "i36", "4736416", "2014", "current", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "29.5", "29.5", "", "", "88.6", "86.6", "", "71.3", "", "2", "", "", "104", "1", "2", "136", "4.9", "0", "", "", "", "0", "", "", "", "", "1", "7.389", "0.161", "0.002", "1.24813", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "", "", "", "", "87.8", "98.4", "", "", "", "", "96.4"]} +{"pcdb_id": 17312, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "30 CDi Classic System", "winter_efficiency_pct": 89.5, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 58.8, "output_kw_max": 30.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017312", "000035", "0", "2020/Sep/08 10:43", "Bosch Thermotechnology", "Worcester", "Greenstar", "30 CDi Classic System", "41-406-38", "2014", "2015", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "30.0", "30.0", "", "", "89.5", "80.5", "", "58.8", "", "2", "1", "", "102", "1", "2", "58", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0305", "", "", "", "", "", "", "", "", "90.0", "100.2", "", "", "", "", "98.3"]} +{"pcdb_id": 17313, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "30 CDi Classic System", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 30.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017313", "000035", "0", "2020/Sep/08 10:43", "Bosch Thermotechnology", "Worcester", "Greenstar", "30 CDi Classic System", "41-406-37", "2014", "2015", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "30.0", "30.0", "", "", "88.5", "79.5", "", "58.1", "", "2", "", "", "102", "1", "2", "58", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0305", "", "", "", "", "", "", "", "", "88.0", "98.0", "", "", "", "", "96.1"]} +{"pcdb_id": 17314, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "40 CDi Classic Regular", "winter_efficiency_pct": 89.5, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 58.8, "output_kw_max": 40.8, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017314", "000035", "0", "2020/Sep/08 10:43", "Bosch Thermotechnology", "Worcester", "Greenstar", "40 CDi Classic Regular", "41-406-36", "2014", "2015", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "40.8", "40.8", "", "", "89.5", "80.5", "", "58.8", "", "2", "1", "", "102", "1", "2", "90", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.8", "100.3", "", "", "", "", "98.3"]} +{"pcdb_id": 17315, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "40 CDi Classic Regular", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 40.8, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017315", "000035", "0", "2020/Sep/08 10:43", "Bosch Thermotechnology", "Worcester", "Greenstar", "40 CDi Classic Regular", "41-406-35", "2014", "2015", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "40.8", "40.8", "", "", "88.5", "79.5", "", "58.1", "", "2", "", "", "102", "1", "2", "90", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "98.1", "", "", "", "", "96.2"]} +{"pcdb_id": 17316, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "30 CDi Classic Regular", "winter_efficiency_pct": 89.5, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 58.8, "output_kw_max": 30.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017316", "000035", "0", "2020/Sep/08 10:43", "Bosch Thermotechnology", "Worcester", "Greenstar", "30 CDi Classic Regular", "41-406-34", "2014", "2015", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "30.0", "30.0", "", "", "89.5", "80.5", "", "58.8", "", "2", "1", "", "102", "1", "2", "58", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.0", "100.2", "", "", "", "", "98.3"]} +{"pcdb_id": 17317, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "30 CDi Classic Regular", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 30.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017317", "000035", "0", "2020/Sep/08 10:43", "Bosch Thermotechnology", "Worcester", "Greenstar", "30 CDi Classic Regular", "41-406-33", "2014", "2015", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "30", "30", "", "", "88.5", "79.5", "", "58.1", "", "2", "", "", "102", "1", "2", "58", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "98.0", "", "", "", "", "96.1"]} +{"pcdb_id": 17318, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "35 CDi Classic System", "winter_efficiency_pct": 89.5, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 58.8, "output_kw_max": 34.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017318", "000035", "0", "2020/Sep/08 10:43", "Bosch Thermotechnology", "Worcester", "Greenstar", "35 CDi Classic System", "41-406-40", "2014", "2015", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "34", "34", "", "", "89.5", "80.5", "", "58.8", "", "2", "1", "", "102", "1", "2", "60", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0305", "", "", "", "", "", "", "", "", "89.8", "100.3", "", "", "", "", "98.3"]} +{"pcdb_id": 17320, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "35 CDi Classic System", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 34.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017320", "000035", "0", "2020/Sep/08 10:44", "Bosch Thermotechnology", "Worcester", "Greenstar", "35 CDi Classic System", "41-406-39", "2014", "2015", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "34", "34", "", "", "88.5", "79.5", "", "58.1", "", "2", "", "", "102", "1", "2", "60", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0305", "", "", "", "", "", "", "", "", "87.8", "98.1", "", "", "", "", "96.2"]} +{"pcdb_id": 17321, "brand_name": "Saturn", "model_name": "NHC 25 E", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 80.9, "comparative_hot_water_efficiency_pct": 56.9, "output_kw_max": 25.129, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017321", "000268", "0", "2014/Oct/17 09:16", "KD Navien", "Saturn", "NHC 25 E", "", "", "2006", "current", "4", "1", "2", "2", "0", "", "", "2", "1", "2", "25.129", "25.129", "", "", "88.3", "80.9", "", "56.9", "", "2", "", "", "202", "1", "1", "143", "115", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "93.6", "94.4", "", "", "", "", "94.3"]} +{"pcdb_id": 17322, "brand_name": "Saturn", "model_name": "NHC 30 E", "model_qualifier": "", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 56.9, "output_kw_max": 30.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017322", "000268", "0", "2014/Nov/26 08:51", "KD Navien", "Saturn", "NHC 30 E", "", "", "2006", "current", "4", "1", "2", "2", "0", "", "", "2", "1", "2", "30", "30", "", "", "88.2", "80.8", "", "56.9", "", "2", "", "", "202", "1", "1", "150", "121", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "93.6", "94.3", "", "", "", "", "94.1"]} +{"pcdb_id": 17323, "brand_name": "Saturn", "model_name": "NHC 41 E", "model_qualifier": "", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 56.8, "output_kw_max": 36.849, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017323", "000268", "0", "2014/Oct/17 09:16", "KD Navien", "Saturn", "NHC 41 E", "", "", "2006", "current", "4", "1", "2", "2", "0", "", "", "2", "1", "2", "36.849", "36.849", "", "", "88.2", "80.8", "", "56.8", "", "2", "", "", "202", "1", "1", "199", "140", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "93.6", "94.1", "", "", "", "", "94.0"]} +{"pcdb_id": 17324, "brand_name": "Baxi", "model_name": "MainEco Combi", "model_qualifier": "35", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 56.1, "output_kw_max": 29.2, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017324", "000005", "0", "2015/Aug/06 12:46", "Baxi Heating UK", "Baxi", "MainEco Combi", "35", "", "2014", "2015", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "29.2", "29.2", "", "", "88.4", "79.8", "", "56.1", "", "2", "", "", "104", "1", "2", "145", "3", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.6", "98.0", "", "", "", "", "96.0"]} +{"pcdb_id": 17325, "brand_name": "Baxi", "model_name": "MainEco Combi", "model_qualifier": "24", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 56.3, "output_kw_max": 19.5, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017325", "000005", "0", "2015/Aug/06 12:47", "Baxi Heating UK", "Baxi", "MainEco Combi", "24", "", "2014", "2015", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "19.5", "19.5", "", "", "88.7", "80.1", "", "56.3", "", "2", "", "", "104", "1", "2", "105", "3", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.4", "98.5", "", "", "", "", "96.6"]} +{"pcdb_id": 17326, "brand_name": "Baxi", "model_name": "MainEco Combi", "model_qualifier": "28", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 56.3, "output_kw_max": 23.4, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017326", "000005", "0", "2015/Aug/06 12:48", "Baxi Heating UK", "Baxi", "MainEco Combi", "28", "", "2014", "2015", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "23.4", "23.4", "", "", "88.6", "80.0", "", "56.3", "", "2", "", "", "104", "1", "2", "117", "3", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "98.4", "", "", "", "", "96.4"]} +{"pcdb_id": 17327, "brand_name": "Baxi", "model_name": "MainEco Heat", "model_qualifier": "15", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 16.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017327", "000005", "0", "2015/Aug/06 12:48", "Baxi Heating UK", "Baxi", "MainEco Heat", "15", "", "2014", "2015", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "16", "16", "", "", "88.5", "79.5", "", "58.1", "", "2", "", "", "102", "1", "2", "20", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "98.0", "", "", "", "", "96.1"]} +{"pcdb_id": 17328, "brand_name": "Baxi", "model_name": "MainEco Heat", "model_qualifier": "18", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 19.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017328", "000005", "0", "2015/Aug/06 12:48", "Baxi Heating UK", "Baxi", "MainEco Heat", "18", "", "2014", "2015", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "19", "19", "", "", "88.5", "79.5", "", "58.0", "", "2", "", "", "102", "1", "2", "23", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "98.0", "", "", "", "", "96.1"]} +{"pcdb_id": 17329, "brand_name": "Baxi", "model_name": "MainEco Heat", "model_qualifier": "24", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 25.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017329", "000005", "0", "2015/Aug/06 12:49", "Baxi Heating UK", "Baxi", "MainEco Heat", "24", "", "2014", "2015", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "25", "25", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "33", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.7", "98.0", "", "", "", "", "96.1"]} +{"pcdb_id": 17330, "brand_name": "Baxi", "model_name": "MainEco System", "model_qualifier": "24", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 23.4, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017330", "000005", "0", "2015/Aug/06 12:49", "Baxi Heating UK", "Baxi", "MainEco System", "24", "", "2014", "2015", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "23.4", "23.4", "", "", "88.6", "79.6", "", "58.2", "", "2", "", "", "102", "1", "2", "103", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "98.4", "", "", "", "", "96.4"]} +{"pcdb_id": 17331, "brand_name": "Baxi", "model_name": "MainEco System", "model_qualifier": "18", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 17.7, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017331", "000005", "0", "2015/Aug/06 12:50", "Baxi Heating UK", "Baxi", "MainEco System", "18", "", "2014", "2015", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "17.7", "17.7", "", "", "88.7", "79.7", "", "58.2", "", "2", "", "", "102", "1", "2", "92", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.5", "98.5", "", "", "", "", "96.6"]} +{"pcdb_id": 17332, "brand_name": "Sime", "model_name": "Murelle Pro HE", "model_qualifier": "25", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 86.9, "comparative_hot_water_efficiency_pct": 67.6, "output_kw_max": 21.4, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0061, "loss_factor_f1_kwh_per_day": 1.63545, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017332", "000213", "0", "2018/Jul/11 10:08", "Fonderie Sime S.p.A.", "Sime", "Murelle Pro HE", "25", "", "2014", "2018", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "21.4", "21.4", "", "", "88.0", "86.9", "", "67.6", "", "2", "", "", "104", "1", "2", "105", "", "0", "", "", "", "0", "", "", "", "", "1", "7.79", "0.129", "0.0061", "1.63545", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.7", "96.4", "", "", "", "", "95.0"]} +{"pcdb_id": 17333, "brand_name": "Sime", "model_name": "Murelle Pro HE", "model_qualifier": "30", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 86.9, "comparative_hot_water_efficiency_pct": 66.4, "output_kw_max": 29.5, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0052, "loss_factor_f1_kwh_per_day": 1.77051, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017333", "000213", "0", "2018/Jul/11 10:32", "Fonderie Sime S.p.A.", "Sime", "Murelle Pro HE", "30", "", "2014", "2018", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "29.5", "29.5", "", "", "87.9", "86.9", "", "66.4", "", "2", "", "", "104", "1", "2", "135", "", "0", "", "", "", "0", "", "", "", "", "1", "7.93", "0.13", "0.0052", "1.77051", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.6", "96.4", "", "", "", "", "94.9"]} +{"pcdb_id": 17334, "brand_name": "Sime", "model_name": "Murelle Pro HE", "model_qualifier": "20 R", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 19.7, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017334", "000213", "0", "2018/Jul/11 10:06", "Fonderie Sime S.p.A.", "Sime", "Murelle Pro HE", "20 R", "", "2014", "2018", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "19.7", "19.7", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "105", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.7", "96.4", "", "", "", "", "95.0"]} +{"pcdb_id": 17335, "brand_name": "Sime", "model_name": "Murelle Pro HE", "model_qualifier": "25", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.4, "comparative_hot_water_efficiency_pct": 56.5, "output_kw_max": 21.4, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017335", "000213", "0", "2018/Jul/11 10:09", "Fonderie Sime S.p.A.", "Sime", "Murelle Pro HE", "25", "", "2014", "2018", "2", "2", "1", "2", "0", "", "", "2", "3", "2", "21.4", "21.4", "", "", "89.0", "80.4", "", "56.5", "", "2", "1", "", "104", "1", "2", "105", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.7", "98.5", "", "", "", "", "97.1"]} +{"pcdb_id": 17336, "brand_name": "Sime", "model_name": "Murelle Pro HE", "model_qualifier": "30", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 56.5, "output_kw_max": 23.6, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017336", "000213", "0", "2018/Jul/11 10:32", "Fonderie Sime S.p.A.", "Sime", "Murelle Pro HE", "30", "", "2014", "2018", "2", "2", "1", "2", "0", "", "", "2", "3", "2", "23.6", "23.6", "", "", "88.9", "80.3", "", "56.5", "", "2", "1", "", "104", "1", "2", "114", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.5", "98.5", "", "", "", "", "97.0"]} +{"pcdb_id": 17337, "brand_name": "Sime", "model_name": "Murelle Pro HE", "model_qualifier": "20 R", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 19.7, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017337", "000213", "0", "2018/Jul/11 10:06", "Fonderie Sime S.p.A.", "Sime", "Murelle Pro HE", "20 R", "", "2014", "2018", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "19.7", "19.7", "", "", "89.0", "80.0", "", "58.4", "", "2", "1", "", "102", "1", "2", "105", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.7", "98.5", "", "", "", "", "97.1"]} +{"pcdb_id": 17338, "brand_name": "Sime", "model_name": "Murelle Pro HE", "model_qualifier": "30 R", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 78.9, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 29.5, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017338", "000213", "0", "2018/Jul/11 10:35", "Fonderie Sime S.p.A.", "Sime", "Murelle Pro HE", "30 R", "", "2014", "2018", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "29.5", "29.5", "", "", "87.9", "78.9", "", "57.7", "", "2", "", "", "102", "1", "2", "135", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.6", "96.4", "", "", "", "", "94.9"]} +{"pcdb_id": 17339, "brand_name": "Sime", "model_name": "Murelle Pro HE", "model_qualifier": "30 R", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 29.5, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017339", "000213", "0", "2018/Jul/11 10:36", "Fonderie Sime S.p.A.", "Sime", "Murelle Pro HE", "30 R", "", "2014", "2018", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "29.5", "29.5", "", "", "88.9", "79.9", "", "58.4", "", "2", "1", "", "102", "1", "2", "135", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.5", "98.5", "", "", "", "", "97.0"]} +{"pcdb_id": 17340, "brand_name": "Sime", "model_name": "Murelle Pro HE", "model_qualifier": "25 LPG", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.4, "comparative_hot_water_efficiency_pct": 56.5, "output_kw_max": 19.7, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017340", "000213", "0", "2018/Jul/11 10:12", "Fonderie Sime S.p.A.", "Sime", "Murelle Pro HE", "25 LPG", "", "2014", "2018", "2", "2", "1", "2", "0", "", "", "2", "3", "2", "19.7", "19.7", "", "", "89.0", "80.4", "", "56.5", "", "2", "1", "", "104", "1", "2", "105", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.7", "98.5", "", "", "", "", "97.1"]} +{"pcdb_id": 17341, "brand_name": "Sime", "model_name": "Murelle Pro HE", "model_qualifier": "25 HO", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 78.9, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 23.6, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017341", "000213", "0", "2018/Jul/11 10:10", "Fonderie Sime S.p.A.", "Sime", "Murelle Pro HE", "25 HO", "", "2014", "2018", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "23.6", "23.6", "", "", "87.9", "78.9", "", "57.7", "", "2", "", "", "102", "1", "2", "35", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.6", "96.4", "", "", "", "", "94.9"]} +{"pcdb_id": 17342, "brand_name": "Sime", "model_name": "Murelle Pro HE", "model_qualifier": "25 HO", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 23.6, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017342", "000213", "0", "2018/Jul/11 10:10", "Fonderie Sime S.p.A.", "Sime", "Murelle Pro HE", "25 HO", "", "2014", "2018", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "23.6", "23.6", "", "", "88.9", "79.9", "", "58.4", "", "2", "1", "", "102", "1", "2", "35", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.5", "98.5", "", "", "", "", "97.0"]} +{"pcdb_id": 17343, "brand_name": "Sime", "model_name": "Murelle Advanced HE", "model_qualifier": "30", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 86.9, "comparative_hot_water_efficiency_pct": 68.0, "output_kw_max": 23.6, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0047, "loss_factor_f1_kwh_per_day": 1.58981, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017343", "000213", "0", "2018/Jul/11 09:47", "Fonderie Sime S.p.A.", "Sime", "Murelle Advanced HE", "30", "", "2014", "2018", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "23.6", "23.6", "", "", "87.9", "86.9", "", "68.0", "", "2", "", "", "104", "1", "2", "114", "", "0", "", "", "", "0", "", "", "", "", "1", "7.74", "0.132", "0.0047", "1.58981", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.6", "96.4", "", "", "", "", "94.9"]} +{"pcdb_id": 17344, "brand_name": "Sime", "model_name": "Murelle Advanced HE", "model_qualifier": "30", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 56.5, "output_kw_max": 23.6, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017344", "000213", "0", "2018/Jul/11 09:47", "Fonderie Sime S.p.A.", "Sime", "Murelle Advanced HE", "30", "", "2014", "2018", "2", "2", "1", "2", "0", "", "", "2", "3", "2", "23.6", "23.6", "", "", "88.9", "80.3", "", "56.5", "", "2", "1", "", "104", "1", "2", "114", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.5", "98.5", "", "", "", "", "97.0"]} +{"pcdb_id": 17345, "brand_name": "Sime", "model_name": "Murelle Advanced HE", "model_qualifier": "40", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 87.0, "comparative_hot_water_efficiency_pct": 60.6, "output_kw_max": 34.5, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0045, "loss_factor_f1_kwh_per_day": 2.51603, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017345", "000213", "0", "2018/Jul/11 09:48", "Fonderie Sime S.p.A.", "Sime", "Murelle Advanced HE", "40", "", "2014", "2018", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "34.5", "34.5", "", "", "88.0", "87.0", "", "60.6", "", "2", "", "", "104", "1", "2", "135", "", "0", "", "", "", "0", "", "", "", "", "1", "8.69", "0.124", "0.0045", "2.51603", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.8", "96.4", "", "", "", "", "95.0"]} +{"pcdb_id": 17346, "brand_name": "Sime", "model_name": "Murelle Advanced HE", "model_qualifier": "40", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.4, "comparative_hot_water_efficiency_pct": 56.5, "output_kw_max": 34.5, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017346", "000213", "0", "2018/Jul/11 09:49", "Fonderie Sime S.p.A.", "Sime", "Murelle Advanced HE", "40", "", "2014", "2018", "2", "2", "1", "2", "0", "", "", "2", "3", "2", "34.5", "34.5", "", "", "89.0", "80.4", "", "56.5", "", "2", "1", "", "104", "1", "2", "135", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.8", "98.5", "", "", "", "", "97.1"]} +{"pcdb_id": 17347, "brand_name": "Sime", "model_name": "Murelle Elite HE", "model_qualifier": "25", "winter_efficiency_pct": 87.8, "summer_efficiency_pct": 86.6, "comparative_hot_water_efficiency_pct": 68.9, "output_kw_max": 23.9, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0031, "loss_factor_f1_kwh_per_day": 1.48334, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017347", "000213", "0", "2018/Jul/11 09:53", "Fonderie Sime S.p.A.", "Sime", "Murelle Elite HE", "25", "", "2014", "2018", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "23.9", "23.9", "", "", "87.8", "86.6", "", "68.9", "", "2", "", "", "104", "1", "2", "125", "", "0", "", "", "", "0", "", "", "", "", "1", "7.64", "0.125", "0.0031", "1.48334", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "96.4", "", "", "", "", "94.8"]} +{"pcdb_id": 17348, "brand_name": "Sime", "model_name": "Murelle Elite HE", "model_qualifier": "25", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 56.4, "output_kw_max": 23.9, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017348", "000213", "0", "2018/Jul/11 09:53", "Fonderie Sime S.p.A.", "Sime", "Murelle Elite HE", "25", "", "2014", "2018", "2", "2", "1", "2", "0", "", "", "2", "3", "2", "23.9", "23.9", "", "", "88.8", "80.2", "", "56.4", "", "2", "1", "", "104", "1", "2", "125", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.8", "98.5", "", "", "", "", "96.9"]} +{"pcdb_id": 17349, "brand_name": "Sime", "model_name": "Murelle Elite HE", "model_qualifier": "30", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 86.8, "comparative_hot_water_efficiency_pct": 68.2, "output_kw_max": 28.9, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0049, "loss_factor_f1_kwh_per_day": 1.56207, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017349", "000213", "0", "2018/Jul/11 09:54", "Fonderie Sime S.p.A.", "Sime", "Murelle Elite HE", "30", "", "2014", "2018", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28.9", "28.9", "", "", "87.9", "86.8", "", "68.2", "", "2", "", "", "104", "1", "2", "130", "0", "0", "", "", "", "0", "", "", "", "", "1", "7.72", "0.122", "0.0049", "1.56207", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "96.4", "", "", "", "", "94.9"]} +{"pcdb_id": 17350, "brand_name": "Sime", "model_name": "Murelle Elite HE", "model_qualifier": "30", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 56.5, "output_kw_max": 28.9, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017350", "000213", "0", "2018/Jul/11 09:55", "Fonderie Sime S.p.A.", "Sime", "Murelle Elite HE", "30", "", "2014", "2018", "2", "2", "1", "2", "0", "", "", "2", "3", "2", "28.9", "28.9", "", "", "88.9", "80.3", "", "56.5", "", "2", "1", "", "104", "1", "2", "130", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.3", "98.5", "", "", "", "", "97.0"]} +{"pcdb_id": 17351, "brand_name": "Sime", "model_name": "Murelle Elite HE", "model_qualifier": "35", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 86.8, "comparative_hot_water_efficiency_pct": 65.4, "output_kw_max": 34.1, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0075, "loss_factor_f1_kwh_per_day": 1.86473, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017351", "000213", "0", "2018/Jul/11 09:56", "Fonderie Sime S.p.A.", "Sime", "Murelle Elite HE", "35", "", "2014", "2018", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "34.1", "34.1", "", "", "87.9", "86.8", "", "65.4", "", "2", "", "", "104", "1", "2", "135", "", "0", "", "", "", "0", "", "", "", "", "1", "8.05", "0.131", "0.0075", "1.86473", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "96.4", "", "", "", "", "94.9"]} +{"pcdb_id": 17353, "brand_name": "Sime", "model_name": "Murelle Elite HE", "model_qualifier": "35", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 56.5, "output_kw_max": 34.1, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017353", "000213", "0", "2018/Jul/11 09:56", "Fonderie Sime S.p.A.", "Sime", "Murelle Elite HE", "35", "", "2014", "2018", "2", "2", "1", "2", "0", "", "", "2", "3", "2", "34.1", "34.1", "", "", "88.9", "80.3", "", "56.5", "", "2", "1", "", "104", "1", "2", "140", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.3", "98.5", "", "", "", "", "97.0"]} +{"pcdb_id": 17354, "brand_name": "Sime", "model_name": "Murelle Elite HE", "model_qualifier": "35 T", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 78.9, "comparative_hot_water_efficiency_pct": 57.6, "output_kw_max": 34.1, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017354", "000213", "0", "2018/Jul/11 09:57", "Fonderie Sime S.p.A.", "Sime", "Murelle Elite HE", "35 T", "", "2014", "2018", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "34.1", "34.1", "", "", "87.9", "78.9", "", "57.6", "", "2", "", "", "102", "1", "2", "140", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "96.4", "", "", "", "", "94.9"]} +{"pcdb_id": 17355, "brand_name": "Sime", "model_name": "Murelle Elite HE", "model_qualifier": "35 T", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 34.1, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017355", "000213", "0", "2018/Jul/11 09:57", "Fonderie Sime S.p.A.", "Sime", "Murelle Elite HE", "35 T", "", "2014", "2018", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "34.1", "34.1", "", "", "88.9", "79.9", "", "58.4", "", "2", "1", "", "102", "1", "2", "140", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.3", "98.5", "", "", "", "", "97.0"]} +{"pcdb_id": 17356, "brand_name": "Sime", "model_name": "Murelle Pro HE", "model_qualifier": "25 R IE", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 78.9, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 23.6, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017356", "000213", "0", "2018/Jul/11 10:30", "Fonderie Sime S.p.A.", "Sime", "Murelle Pro HE", "25 R IE", "", "2014", "2018", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "23.6", "23.6", "", "", "87.9", "78.9", "", "57.7", "", "2", "", "", "102", "1", "2", "105", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.6", "96.4", "", "", "", "", "94.9"]} +{"pcdb_id": 17357, "brand_name": "Sime", "model_name": "Murelle Pro HE", "model_qualifier": "25 R IE", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 23.6, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017357", "000213", "0", "2018/Jul/11 10:31", "Fonderie Sime S.p.A.", "Sime", "Murelle Pro HE", "25 R IE", "", "2014", "2018", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "23.6", "23.6", "", "", "88.9", "79.9", "", "58.4", "", "2", "1", "", "102", "1", "2", "135", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.5", "98.5", "", "", "", "", "97.0"]} +{"pcdb_id": 17358, "brand_name": "Sime", "model_name": "Murelle Pro HE", "model_qualifier": "30 R IE", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 78.9, "comparative_hot_water_efficiency_pct": 57.6, "output_kw_max": 29.5, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017358", "000213", "0", "2018/Jul/11 10:37", "Fonderie Sime S.p.A.", "Sime", "Murelle Pro HE", "30 R IE", "", "2014", "2018", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "29.5", "29.5", "", "", "87.9", "78.9", "", "57.6", "", "2", "", "", "102", "1", "2", "135", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "96.4", "", "", "", "", "94.9"]} +{"pcdb_id": 17359, "brand_name": "Sime", "model_name": "Murelle Pro HE", "model_qualifier": "30 R IE", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 29.5, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017359", "000213", "0", "2018/Jul/11 10:39", "Fonderie Sime S.p.A.", "Sime", "Murelle Pro HE", "30 R IE", "", "2014", "2018", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "29.5", "29.5", "", "", "88.9", "79.9", "", "58.4", "", "2", "1", "", "102", "1", "2", "135", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.5", "98.5", "", "", "", "", "97.0"]} +{"pcdb_id": 17360, "brand_name": "Sime", "model_name": "Murelle Pro HE", "model_qualifier": "35 R IE", "winter_efficiency_pct": 87.8, "summer_efficiency_pct": 78.8, "comparative_hot_water_efficiency_pct": 57.6, "output_kw_max": 34.1, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017360", "000213", "0", "2018/Jul/11 10:39", "Fonderie Sime S.p.A.", "Sime", "Murelle Pro HE", "35 R IE", "", "2014", "2018", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "34.1", "34.1", "", "", "87.8", "78.8", "", "57.6", "", "2", "", "", "102", "1", "2", "135", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "96.4", "", "", "", "", "94.8"]} +{"pcdb_id": 17361, "brand_name": "Sime", "model_name": "Murelle Pro HE", "model_qualifier": "35 R IE", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 34.1, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017361", "000213", "0", "2018/Jul/11 11:02", "Fonderie Sime S.p.A.", "Sime", "Murelle Pro HE", "35 R IE", "", "2014", "2018", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "34.1", "34.1", "", "", "88.8", "79.8", "", "58.3", "", "2", "1", "", "102", "1", "2", "135", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.8", "98.5", "", "", "", "", "96.9"]} +{"pcdb_id": 17362, "brand_name": "Sime", "model_name": "Murelle Pro HE", "model_qualifier": "40 R IE", "winter_efficiency_pct": 87.8, "summer_efficiency_pct": 78.8, "comparative_hot_water_efficiency_pct": 57.6, "output_kw_max": 39.1, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017362", "000213", "0", "2018/Jul/11 11:02", "Fonderie Sime S.p.A.", "Sime", "Murelle Pro HE", "40 R IE", "", "2014", "2018", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "39.1", "39.1", "", "", "87.8", "78.8", "", "57.6", "", "2", "", "", "102", "1", "2", "135", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "96.4", "", "", "", "", "94.8"]} +{"pcdb_id": 17363, "brand_name": "Sime", "model_name": "Murelle Pro HE", "model_qualifier": "40 R IE", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 39.1, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017363", "000213", "0", "2018/Jul/11 11:03", "Fonderie Sime S.p.A.", "Sime", "Murelle Pro HE", "40 R IE", "", "2014", "2018", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "39.1", "39.1", "", "", "88.8", "79.8", "", "58.3", "", "2", "1", "", "102", "1", "2", "135", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.9", "98.5", "", "", "", "", "96.9"]} +{"pcdb_id": 17364, "brand_name": "Sime", "model_name": "Murelle Pro HE", "model_qualifier": "30 IE", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 86.9, "comparative_hot_water_efficiency_pct": 66.4, "output_kw_max": 23.6, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0052, "loss_factor_f1_kwh_per_day": 1.77051, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017364", "000213", "0", "2018/Jul/11 10:33", "Fonderie Sime S.p.A.", "Sime", "Murelle Pro HE", "30 IE", "", "2014", "2018", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "23.6", "23.6", "", "", "87.9", "86.9", "", "66.4", "", "2", "", "", "104", "1", "2", "114", "", "0", "", "", "", "0", "", "", "", "", "1", "7.93", "0.13", "0.0052", "1.77051", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.6", "96.4", "", "", "", "", "94.9"]} +{"pcdb_id": 17365, "brand_name": "Sime", "model_name": "Murelle Pro HE", "model_qualifier": "30 IE", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 56.5, "output_kw_max": 23.6, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017365", "000213", "0", "2018/Jul/11 10:34", "Fonderie Sime S.p.A.", "Sime", "Murelle Pro HE", "30 IE", "", "2014", "2018", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "23.6", "23.6", "", "", "88.9", "80.3", "", "56.5", "", "2", "1", "", "104", "1", "2", "114", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.5", "98.5", "", "", "", "", "97.0"]} +{"pcdb_id": 17367, "brand_name": "Daikin", "model_name": "EKOMBU28AAV1", "model_qualifier": "", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 62.1, "output_kw_max": 23.1, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017367", "000278", "0", "2016/Feb/15 12:00", "Daikin Europe NV", "Daikin", "EKOMBU28AAV1", "", "GC 47-464-06", "2014", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "23.1", "23.1", "", "", "88.2", "79.6", "", "62.1", "", "2", "", "", "104", "1", "2", "105", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "", "0005", "", "", "", "", "", "", "", "", "87.9", "97.2", "", "", "", "", "95.5"]} +{"pcdb_id": 17369, "brand_name": "Daikin", "model_name": "EKOMBU33AAV1", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 62.3, "output_kw_max": 26.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017369", "000278", "0", "2016/Feb/15 12:01", "Daikin Europe NV", "Daikin", "EKOMBU33AAV1", "", "GC 47-464-07", "2014", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "26.6", "26.6", "", "", "88.5", "79.9", "", "62.3", "", "2", "", "", "104", "1", "2", "105", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "", "0005", "", "", "", "", "", "", "", "", "88.9", "97.6", "", "", "", "", "95.9"]} +{"pcdb_id": 17371, "brand_name": "Daikin", "model_name": "EKOMBGU28AAV1", "model_qualifier": "", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 62.1, "output_kw_max": 23.1, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017371", "000278", "0", "2016/Feb/15 12:02", "Daikin Europe NV", "Daikin", "EKOMBGU28AAV1", "", "GC 47-464-03", "2014", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "23.1", "23.1", "", "", "88.2", "79.6", "", "62.1", "", "2", "", "", "104", "1", "2", "80", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "", "0005", "", "", "", "", "", "", "", "", "87.9", "97.2", "", "", "", "", "95.5"]} +{"pcdb_id": 17373, "brand_name": "Daikin", "model_name": "EKOMBGU22AAV1", "model_qualifier": "", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 62.1, "output_kw_max": 18.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017373", "000278", "0", "2016/Feb/15 12:02", "Daikin Europe NV", "Daikin", "EKOMBGU22AAV1", "", "GC 47-464-02", "2014", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "18.2", "18.2", "", "", "88.2", "79.6", "", "62.1", "", "2", "", "", "104", "1", "2", "80", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "", "0005", "", "", "", "", "", "", "", "", "87.8", "97.4", "", "", "", "", "95.6"]} +{"pcdb_id": 17375, "brand_name": "Daikin", "model_name": "EKOMBU22AAV1", "model_qualifier": "", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 62.1, "output_kw_max": 18.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017375", "000278", "0", "2016/Feb/15 12:03", "Daikin Europe NV", "Daikin", "EKOMBU22AAV1", "", "GC 47-464-05", "2014", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "18.2", "18.2", "", "", "88.2", "79.6", "", "62.1", "", "2", "", "", "104", "1", "2", "105", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "", "0005", "", "", "", "", "", "", "", "", "87.8", "97.4", "", "", "", "", "95.6"]} +{"pcdb_id": 17377, "brand_name": "Daikin", "model_name": "EKOMBGU33AAV1", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 62.3, "output_kw_max": 26.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017377", "000278", "0", "2016/Feb/15 12:04", "Daikin Europe NV", "Daikin", "EKOMBGU33AAV1", "", "GC 47-464-04", "2014", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "26.6", "26.6", "", "", "88.5", "79.9", "", "62.3", "", "2", "", "", "104", "1", "2", "80", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "", "0005", "", "", "", "", "", "", "", "", "88.9", "97.6", "", "", "", "", "95.9"]} +{"pcdb_id": 17378, "brand_name": "Vokera", "model_name": "Vibe", "model_qualifier": "25A", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 24.45, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017378", "000011", "0", "2014/Oct/10 08:56", "Vokera", "Vokera", "Vibe", "25A", "41 094 85", "2014", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "24.45", "24.45", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "107", "4.5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "88.1", "97.7", "", "", "", "", "95.9"]} +{"pcdb_id": 17379, "brand_name": "Vokera", "model_name": "Vibe", "model_qualifier": "20A", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 19.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017379", "000011", "0", "2014/Oct/10 08:56", "Vokera", "Vokera", "Vibe", "20A", "41 094 84", "2014", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "19.50", "19.50", "", "", "88.5", "79.5", "", "58.1", "", "2", "", "", "102", "1", "2", "96", "4.5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "87.8", "98.1", "", "", "", "", "96.2"]} +{"pcdb_id": 17380, "brand_name": "ROC", "model_name": "L1GB37-B40CP", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 56.2, "output_kw_max": 37.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017380", "000285", "0", "2014/Nov/14 10:16", "Guangdong ROC Cool and Heat Equipment Co Ltd", "ROC", "L1GB37-B40CP", "", "", "2014", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "37", "37", "", "", "88.5", "79.9", "", "56.2", "", "2", "", "", "104", "1", "2", "110", "1", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.1", "97.9", "", "", "", "", "96.1"]} +{"pcdb_id": 17381, "brand_name": "Alpha", "model_name": "Eco2", "model_qualifier": "", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 88.5, "comparative_hot_water_efficiency_pct": 73.9, "output_kw_max": 24.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.009, "loss_factor_f1_kwh_per_day": 1.10772, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017381", "000001", "0", "2015/Mar/16 14:39", "Alpha Therm", "Alpha", "Eco2", "", "", "2014", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "89.2", "88.5", "", "73.9", "", "2", "1", "", "104", "1", "2", "115", "4.5", "0", "", "", "", "0", "", "", "", "", "1", "7.288", "0.129", "0.009", "1.10772", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.7", "99.6", "", "", "", "", "97.7"]} +{"pcdb_id": 17382, "brand_name": "Alpha", "model_name": "Eco2", "model_qualifier": "", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 86.6, "comparative_hot_water_efficiency_pct": 72.1, "output_kw_max": 24.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0145, "loss_factor_f1_kwh_per_day": 1.09508, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017382", "000001", "0", "2015/Apr/13 09:31", "Alpha Therm", "Alpha", "Eco2", "", "", "2014", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "88.2", "86.6", "", "72.1", "", "2", "", "", "104", "1", "2", "115", "4.5", "0", "", "", "", "0", "", "", "", "", "1", "7.308", "0.134", "0.0145", "1.09508", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "97.4", "", "", "", "", "95.6"]} +{"pcdb_id": 17383, "brand_name": "Alpha", "model_name": "InTec2 25 X", "model_qualifier": "", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 88.5, "comparative_hot_water_efficiency_pct": 74.7, "output_kw_max": 20.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.017, "loss_factor_f1_kwh_per_day": 0.98598, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017383", "000001", "0", "2015/Mar/16 14:39", "Alpha Therm", "Alpha", "InTec2 25 X", "", "", "2014", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "20.0", "20.0", "", "", "89.2", "88.5", "", "74.7", "", "2", "1", "", "104", "1", "2", "110", "4.5", "0", "", "", "", "0", "", "", "", "", "1", "7.21", "0.132", "0.017", "0.98598", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.7", "99.5", "", "", "", "", "97.6"]} +{"pcdb_id": 17384, "brand_name": "Alpha", "model_name": "InTec2 25 X", "model_qualifier": "", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 86.6, "comparative_hot_water_efficiency_pct": 73.0, "output_kw_max": 20.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0147, "loss_factor_f1_kwh_per_day": 1.00537, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017384", "000001", "0", "2015/Apr/13 09:31", "Alpha Therm", "Alpha", "InTec2 25 X", "", "", "2014", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "20.0", "20.0", "", "", "88.2", "86.6", "", "73.0", "", "2", "", "", "104", "1", "2", "110", "4.5", "0", "", "", "", "0", "", "", "", "", "1", "7.216", "0.133", "0.0147", "1.00537", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "97.3", "", "", "", "", "95.5"]} +{"pcdb_id": 17385, "brand_name": "Alpha", "model_name": "InTec2 28 X", "model_qualifier": "", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 88.5, "comparative_hot_water_efficiency_pct": 73.9, "output_kw_max": 24.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0091, "loss_factor_f1_kwh_per_day": 1.10713, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017385", "000001", "0", "2015/Mar/16 14:40", "Alpha Therm", "Alpha", "InTec2 28 X", "", "", "2014", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24.0", "24.0", "", "", "89.2", "88.5", "", "73.9", "", "2", "1", "", "104", "1", "2", "115", "4.5", "0", "", "", "", "0", "", "", "", "", "1", "7.288", "0.129", "0.0091", "1.10713", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.7", "99.6", "", "", "", "", "97.7"]} +{"pcdb_id": 17386, "brand_name": "Alpha", "model_name": "InTec2 28X", "model_qualifier": "", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 86.6, "comparative_hot_water_efficiency_pct": 72.1, "output_kw_max": 24.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0145, "loss_factor_f1_kwh_per_day": 1.09508, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017386", "000001", "0", "2015/Apr/13 09:31", "Alpha Therm", "Alpha", "InTec2 28X", "", "", "2014", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.0", "24.0", "", "", "88.2", "86.6", "", "72.1", "", "2", "", "", "104", "1", "2", "115", "4.5", "0", "", "", "", "0", "", "", "", "", "1", "7.308", "0.134", "0.0145", "1.09508", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "97.4", "", "", "", "", "95.6"]} +{"pcdb_id": 17387, "brand_name": "Worcester", "model_name": "GB 162-50 kW", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 50.0, "final_year_of_manufacture": 2016, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017387", "000035", "0", "2020/Sep/08 10:44", "Bosch Thermotechnology", "Worcester", "GB 162-50 kW", "", "7736700642", "2015", "2016", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "50", "50", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "9", "45", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.4", "96.6", "", "", "", "", "95.0"]} +{"pcdb_id": 17388, "brand_name": "Intergas", "model_name": "Combi Compact ECO RF 36", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 87.0, "comparative_hot_water_efficiency_pct": 77.0, "output_kw_max": 26.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0116, "loss_factor_f1_kwh_per_day": 0.68904, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017388", "000256", "0", "2018/Dec/05 13:02", "Intergas Heating Ltd", "Intergas", "Combi Compact ECO RF 36", "", "", "2013", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "26.6", "26.6", "", "", "88.5", "87.0", "", "77.0", "", "2", "", "", "104", "1", "2", "80", "2", "0", "", "", "", "0", "", "", "", "", "1", "6.838", "0.06", "0.0116", "0.68904", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.9", "97.6", "", "", "", "", "95.9"]} +{"pcdb_id": 17389, "brand_name": "Intergas", "model_name": "Combi Compact ECO RF 30", "model_qualifier": "", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 86.7, "comparative_hot_water_efficiency_pct": 76.8, "output_kw_max": 23.1, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0, "loss_factor_f1_kwh_per_day": 0.74956, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017389", "000256", "0", "2014/Nov/25 08:57", "Intergas Heating Ltd", "Intergas", "Combi Compact ECO RF 30", "", "", "2013", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "23.1", "23.1", "", "", "88.2", "86.7", "", "76.8", "", "2", "", "", "104", "1", "2", "80", "2", "0", "", "", "", "0", "", "", "", "", "1", "6.856", "0.057", "0.0", "0.74956", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "97.2", "", "", "", "", "95.5"]} +{"pcdb_id": 17390, "brand_name": "Intergas", "model_name": "Combi Compact ECO RF 24", "model_qualifier": "", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 86.6, "comparative_hot_water_efficiency_pct": 76.1, "output_kw_max": 18.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0005, "loss_factor_f1_kwh_per_day": 0.80108, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017390", "000256", "0", "2014/Nov/25 08:57", "Intergas Heating Ltd", "Intergas", "Combi Compact ECO RF 24", "", "", "2013", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "18.2", "18.2", "", "", "88.2", "86.6", "", "76.1", "", "2", "", "", "104", "1", "2", "80", "2", "0", "", "", "", "0", "", "", "", "", "1", "6.917", "0.6", "0.0005", "0.80108", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "97.4", "", "", "", "", "95.6"]} +{"pcdb_id": 17392, "brand_name": "Viadrus", "model_name": "K4", "model_qualifier": "K4G2H24PW", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 56.1, "output_kw_max": 22.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017392", "000292", "0", "2016/Jan/06 09:27", "Viadrus a.s", "Viadrus", "K4", "K4G2H24PW", "", "2014", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "22.2", "22.2", "", "", "88.3", "79.7", "", "56.1", "", "2", "1", "", "104", "1", "2", "65", "4", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.8", "97.3", "", "", "", "", "95.9"]} +{"pcdb_id": 17393, "brand_name": "Viadrus", "model_name": "K4", "model_qualifier": "K4G3H24PB", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 22.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017393", "000292", "0", "2016/Jan/06 09:25", "Viadrus a.s", "Viadrus", "K4", "K4G3H24PB", "", "2014", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "22.2", "22.2", "", "", "88.3", "79.3", "", "58.0", "", "2", "1", "", "102", "1", "2", "65", "4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.8", "97.3", "", "", "", "", "95.9"]} +{"pcdb_id": 17394, "brand_name": "Viadrus", "model_name": "K4", "model_qualifier": "K4G3H24ZW", "winter_efficiency_pct": 87.4, "summer_efficiency_pct": 78.4, "comparative_hot_water_efficiency_pct": 57.2, "output_kw_max": 22.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017394", "000292", "0", "2016/Jan/06 09:41", "Viadrus a.s", "Viadrus", "K4", "K4G3H24ZW", "", "2014", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "22.3", "22.3", "", "", "87.4", "78.4", "", "57.2", "", "2", "", "", "102", "1", "2", "65", "4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "95.2", "", "", "", "", "93.8"]} +{"pcdb_id": 17395, "brand_name": "Viadrus", "model_name": "K4", "model_qualifier": "K4G3H24ZR", "winter_efficiency_pct": 87.4, "summer_efficiency_pct": 78.4, "comparative_hot_water_efficiency_pct": 57.2, "output_kw_max": 22.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017395", "000292", "0", "2016/Jan/06 09:40", "Viadrus a.s", "Viadrus", "K4", "K4G3H24ZR", "", "2014", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "22.3", "22.3", "", "", "87.4", "78.4", "", "57.2", "", "2", "", "", "102", "1", "2", "65", "4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "95.2", "", "", "", "", "93.8"]} +{"pcdb_id": 17396, "brand_name": "Viadrus", "model_name": "K4", "model_qualifier": "K4G3H24ZB", "winter_efficiency_pct": 87.4, "summer_efficiency_pct": 78.4, "comparative_hot_water_efficiency_pct": 57.2, "output_kw_max": 22.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017396", "000292", "0", "2016/Jan/06 09:39", "Viadrus a.s", "Viadrus", "K4", "K4G3H24ZB", "", "2014", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "22.3", "22.3", "", "", "87.4", "78.4", "", "57.2", "", "2", "", "", "102", "1", "2", "65", "4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "95.2", "", "", "", "", "93.8"]} +{"pcdb_id": 17397, "brand_name": "Viadrus", "model_name": "K4", "model_qualifier": "K4G3H24PW", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 22.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017397", "000292", "0", "2016/Jan/06 09:30", "Viadrus a.s", "Viadrus", "K4", "K4G3H24PW", "", "2014", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "22.2", "22.2", "", "", "88.3", "79.3", "", "58.0", "", "2", "1", "", "102", "1", "2", "65", "4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.8", "97.3", "", "", "", "", "95.9"]} +{"pcdb_id": 17398, "brand_name": "Viadrus", "model_name": "K4", "model_qualifier": "K4G3H24ZS", "winter_efficiency_pct": 87.4, "summer_efficiency_pct": 78.4, "comparative_hot_water_efficiency_pct": 57.2, "output_kw_max": 22.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017398", "000292", "0", "2016/Jan/06 09:35", "Viadrus a.s", "Viadrus", "K4", "K4G3H24ZS", "", "2014", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "22.3", "22.3", "", "", "87.4", "78.4", "", "57.2", "", "2", "", "", "102", "1", "2", "65", "4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "95.2", "", "", "", "", "93.8"]} +{"pcdb_id": 17399, "brand_name": "Viadrus", "model_name": "K4", "model_qualifier": "K4G2H24ZB", "winter_efficiency_pct": 87.4, "summer_efficiency_pct": 78.8, "comparative_hot_water_efficiency_pct": 55.4, "output_kw_max": 22.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017399", "000292", "0", "2016/Jan/06 09:33", "Viadrus a.s", "Viadrus", "K4", "K4G2H24ZB", "", "2014", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "22.3", "22.3", "", "", "87.4", "78.8", "", "55.4", "", "2", "", "", "104", "1", "2", "65", "4", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "95.2", "", "", "", "", "93.8"]} +{"pcdb_id": 17400, "brand_name": "Viadrus", "model_name": "K4", "model_qualifier": "K4G2H24ZR", "winter_efficiency_pct": 87.4, "summer_efficiency_pct": 78.8, "comparative_hot_water_efficiency_pct": 55.4, "output_kw_max": 22.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017400", "000292", "0", "2016/Jan/06 09:35", "Viadrus a.s", "Viadrus", "K4", "K4G2H24ZR", "", "2014", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "22.3", "22.3", "", "", "87.4", "78.8", "", "55.4", "", "2", "", "", "104", "1", "2", "65", "4", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "95.2", "", "", "", "", "93.8"]} +{"pcdb_id": 17401, "brand_name": "Viadrus", "model_name": "K4", "model_qualifier": "K4G2H24ZW", "winter_efficiency_pct": 87.4, "summer_efficiency_pct": 78.8, "comparative_hot_water_efficiency_pct": 55.4, "output_kw_max": 22.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017401", "000292", "0", "2016/Jan/06 09:36", "Viadrus a.s", "Viadrus", "K4", "K4G2H24ZW", "", "2014", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "22.3", "22.3", "", "", "87.4", "78.8", "", "55.4", "", "2", "", "", "104", "1", "2", "65", "4", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "95.2", "", "", "", "", "93.8"]} +{"pcdb_id": 17402, "brand_name": "Viadrus", "model_name": "K4", "model_qualifier": "K4G2H24ZS", "winter_efficiency_pct": 87.4, "summer_efficiency_pct": 78.8, "comparative_hot_water_efficiency_pct": 55.4, "output_kw_max": 22.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017402", "000292", "0", "2016/Jan/06 09:37", "Viadrus a.s", "Viadrus", "K4", "K4G2H24ZS", "", "2014", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "22.3", "22.3", "", "", "87.4", "78.8", "", "55.4", "", "2", "", "", "104", "1", "2", "65", "4", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "95.2", "", "", "", "", "93.8"]} +{"pcdb_id": 17403, "brand_name": "Viadrus", "model_name": "K4", "model_qualifier": "K4G1H24PW", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 22.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017403", "000292", "0", "2016/Jan/06 09:23", "Viadrus a.s", "Viadrus", "K4", "K4G1H24PW", "", "2014", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "22.2", "22.2", "", "", "88.3", "79.3", "", "58.0", "", "2", "1", "", "102", "1", "2", "65", "4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.8", "97.3", "", "", "", "", "95.9"]} +{"pcdb_id": 17404, "brand_name": "Viadrus", "model_name": "K4", "model_qualifier": "K4G1H24ZW", "winter_efficiency_pct": 87.4, "summer_efficiency_pct": 78.4, "comparative_hot_water_efficiency_pct": 57.2, "output_kw_max": 22.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017404", "000292", "0", "2016/Jan/06 09:38", "Viadrus a.s", "Viadrus", "K4", "K4G1H24ZW", "", "2014", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "22.3", "22.3", "", "", "87.4", "78.4", "", "57.2", "", "2", "", "", "102", "1", "2", "65", "4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "95.2", "", "", "", "", "93.8"]} +{"pcdb_id": 17405, "brand_name": "Viadrus", "model_name": "K4", "model_qualifier": "K4G2H24PB", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 56.1, "output_kw_max": 22.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 3, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017405", "000292", "0", "2016/Jan/06 09:23", "Viadrus a.s", "Viadrus", "K4", "K4G2H24PB", "", "2014", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "22.2", "22.2", "", "", "88.3", "79.7", "", "56.1", "", "2", "1", "", "104", "1", "2", "65", "4", "3", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.8", "97.3", "", "", "", "", "95.9"]} +{"pcdb_id": 17406, "brand_name": "Viadrus", "model_name": "K4", "model_qualifier": "K4G1H24PR", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 22.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017406", "000292", "0", "2016/Jan/06 09:22", "Viadrus a.s", "Viadrus", "K4", "K4G1H24PR", "", "2014", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "22.2", "22.2", "", "", "88.3", "79.3", "", "58.0", "", "2", "1", "", "102", "1", "2", "65", "4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.8", "97.3", "", "", "", "", "95.9"]} +{"pcdb_id": 17407, "brand_name": "Viadrus", "model_name": "K4", "model_qualifier": "K4G1H24PS", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 22.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017407", "000292", "0", "2016/Jan/06 09:22", "Viadrus a.s", "Viadrus", "K4", "K4G1H24PS", "", "2014", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "22.2", "22.2", "", "", "88.3", "79.3", "", "58.0", "", "2", "1", "", "102", "1", "2", "65", "4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.8", "97.3", "", "", "", "", "95.9"]} +{"pcdb_id": 17408, "brand_name": "Viadrus", "model_name": "K4", "model_qualifier": "K4G1H24ZS", "winter_efficiency_pct": 87.4, "summer_efficiency_pct": 78.4, "comparative_hot_water_efficiency_pct": 57.2, "output_kw_max": 22.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017408", "000292", "0", "2016/Jan/06 09:42", "Viadrus a.s", "Viadrus", "K4", "K4G1H24ZS", "", "2014", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "22.3", "22.3", "", "", "87.4", "78.4", "", "57.2", "", "2", "", "", "102", "1", "2", "65", "4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "95.2", "", "", "", "", "93.8"]} +{"pcdb_id": 17409, "brand_name": "Viadrus", "model_name": "K4", "model_qualifier": "K4G1H24ZB", "winter_efficiency_pct": 87.4, "summer_efficiency_pct": 78.4, "comparative_hot_water_efficiency_pct": 57.2, "output_kw_max": 22.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017409", "000292", "0", "2016/Jan/06 09:34", "Viadrus a.s", "Viadrus", "K4", "K4G1H24ZB", "", "2014", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "22.3", "22.3", "", "", "87.4", "78.4", "", "57.2", "", "2", "", "", "102", "1", "2", "65", "4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "95.2", "", "", "", "", "93.8"]} +{"pcdb_id": 17410, "brand_name": "Viadrus", "model_name": "K4", "model_qualifier": "K4G1H24PB", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 22.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017410", "000292", "0", "2016/Jan/06 09:29", "Viadrus a.s", "Viadrus", "K4", "K4G1H24PB", "", "2014", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "22.2", "22.2", "", "", "88.3", "79.3", "", "58.0", "", "2", "1", "", "102", "1", "2", "65", "4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.8", "97.3", "", "", "", "", "95.9"]} +{"pcdb_id": 17411, "brand_name": "Viadrus", "model_name": "K4", "model_qualifier": "K4G2H24PR", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 56.1, "output_kw_max": 22.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017411", "000292", "0", "2016/Jan/06 09:28", "Viadrus a.s", "Viadrus", "K4", "K4G2H24PR", "", "2014", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "22.4", "22.4", "", "", "88.3", "79.7", "", "56.1", "", "2", "1", "", "104", "1", "2", "65", "4", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.8", "97.3", "", "", "", "", "95.9"]} +{"pcdb_id": 17412, "brand_name": "Viadrus", "model_name": "K4", "model_qualifier": "K4G1H24ZR", "winter_efficiency_pct": 87.4, "summer_efficiency_pct": 78.4, "comparative_hot_water_efficiency_pct": 57.2, "output_kw_max": 22.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017412", "000292", "0", "2016/Jan/06 09:31", "Viadrus a.s", "Viadrus", "K4", "K4G1H24ZR", "", "2014", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "22.3", "22.3", "", "", "87.4", "78.4", "", "57.2", "", "2", "", "", "102", "1", "2", "65", "4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "95.2", "", "", "", "", "93.8"]} +{"pcdb_id": 17413, "brand_name": "Viadrus", "model_name": "K4", "model_qualifier": "K4G2H24PS", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 56.1, "output_kw_max": 22.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017413", "000292", "0", "2016/Jan/06 09:21", "Viadrus a.s", "Viadrus", "K4", "K4G2H24PS", "", "2014", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "22.2", "22.2", "", "", "88.3", "79.7", "", "56.1", "", "2", "1", "", "104", "1", "2", "65", "4", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.8", "97.3", "", "", "", "", "95.9"]} +{"pcdb_id": 17414, "brand_name": "Viadrus", "model_name": "K4", "model_qualifier": "K4G3H24PR", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 22.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017414", "000292", "0", "2016/Jan/06 09:26", "Viadrus a.s", "Viadrus", "K4", "K4G3H24PR", "", "2014", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "22.2", "22.2", "", "", "88.3", "79.3", "", "58.0", "", "2", "1", "", "102", "1", "2", "65", "4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.8", "97.3", "", "", "", "", "95.9"]} +{"pcdb_id": 17415, "brand_name": "Viadrus", "model_name": "K4", "model_qualifier": "K4G3H24PS", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 22.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017415", "000292", "0", "2016/Jan/06 09:31", "Viadrus a.s", "Viadrus", "K4", "K4G3H24PS", "", "2014", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "22.2", "22.2", "", "", "88.3", "79.3", "", "58.0", "", "2", "1", "", "102", "1", "2", "65", "4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.8", "97.3", "", "", "", "", "95.9"]} +{"pcdb_id": 17417, "brand_name": "Viessmann", "model_name": "Vitodens 050-W BPJC", "model_qualifier": "29kW Combi Boiler", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 84.7, "comparative_hot_water_efficiency_pct": 64.0, "output_kw_max": 21.8, "final_year_of_manufacture": 2016, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.0111, "loss_factor_f1_kwh_per_day": 2.00571, "loss_factor_f2_kwh_per_day": 1.67227, "rejected_factor_f3_per_litre": 7e-05, "raw": ["017417", "000033", "0", "2020/Apr/09 16:18", "Viessmann", "Viessmann", "Vitodens 050-W BPJC", "29kW Combi Boiler", "GC 47 819 31", "2014", "2016", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "21.8", "21.8", "", "", "88.4", "84.7", "", "64.0", "", "2", "", "", "104", "1", "2", "97", "2.71", "0", "", "", "0", "0", "", "", "", "", "2", "8.235", "0.114", "0.0111", "2.00571", "14.399", "0.134", "0.004", "1.67227", "0.00007", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "98.0", "", "", "", "", "96.1"]} +{"pcdb_id": 17419, "brand_name": "Viessmann", "model_name": "Vitodens 050-W BPJC", "model_qualifier": "35kW Combi Boiler", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 84.1, "comparative_hot_water_efficiency_pct": 64.2, "output_kw_max": 30.1, "final_year_of_manufacture": 2016, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.0054, "loss_factor_f1_kwh_per_day": 2.00903, "loss_factor_f2_kwh_per_day": 1.62647, "rejected_factor_f3_per_litre": 3e-05, "raw": ["017419", "000033", "0", "2020/Apr/09 16:18", "Viessmann", "Viessmann", "Vitodens 050-W BPJC", "35kW Combi Boiler", "GC 47 819 32", "2014", "2016", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "30.1", "30.1", "", "", "88.4", "84.1", "", "64.2", "", "2", "", "", "104", "1", "2", "141", "2.71", "0", "", "", "", "0", "", "", "", "", "2", "8.201", "0.121", "0.0054", "2.00903", "14.415", "0.141", "0.002", "1.62647", "0.00003", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "97.9", "", "", "", "", "96.0"]} +{"pcdb_id": 17422, "brand_name": "Unical", "model_name": "KON C HE", "model_qualifier": "Combi Boiler", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 56.1, "output_kw_max": 17.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017422", "000263", "0", "2015/Feb/24 10:54", "Unical AG", "Unical", "KON C HE", "Combi Boiler", "", "2013", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "17.4", "17.4", "", "", "88.4", "79.8", "", "56.1", "", "2", "", "", "104", "1", "2", "108", "9", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.1", "97.8", "", "", "", "", "95.9"]} +{"pcdb_id": 17423, "brand_name": "Unical", "model_name": "KON R HE", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 17.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017423", "000263", "0", "2015/Feb/24 10:54", "Unical AG", "Unical", "KON R HE", "", "", "2013", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "17.4", "17.4", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "108", "9", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.1", "97.8", "", "", "", "", "95.9"]} +{"pcdb_id": 17424, "brand_name": "Unical", "model_name": "KON C 28 HE", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 56.2, "output_kw_max": 27.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017424", "000263", "0", "2015/Feb/24 10:55", "Unical AG", "Unical", "KON C 28 HE", "", "", "2014", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "27.2", "27.2", "", "", "88.5", "79.9", "", "56.2", "", "2", "", "", "104", "1", "2", "116", "9", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "97.9", "", "", "", "", "96.1"]} +{"pcdb_id": 17425, "brand_name": "Unical", "model_name": "KON R 28 HE", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 27.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017425", "000263", "0", "2015/Feb/24 10:55", "Unical AG", "Unical", "KON R 28 HE", "", "", "2014", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "27.2", "27.2", "", "", "88.5", "79.5", "", "58.0", "", "2", "", "", "102", "1", "2", "116", "9", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "97.9", "", "", "", "", "96.1"]} +{"pcdb_id": 17430, "brand_name": "Ravenheat", "model_name": "CS 80(T)", "model_qualifier": "Natural Gas", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 86.6, "comparative_hot_water_efficiency_pct": 76.3, "output_kw_max": 19.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0104, "loss_factor_f1_kwh_per_day": 0.73076, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017430", "000026", "0", "2015/May/06 11:50", "Ravenheat Manufacturing", "Ravenheat", "CS 80(T)", "Natural Gas", "", "2015", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "19.5", "19.5", "", "", "88.0", "86.6", "", "76.3", "", "2", "", "", "104", "1", "2", "110", "3", "0", "", "", "", "0", "", "", "", "", "1", "6.902", "0.134", "0.0104", "0.73076", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "96.9", "", "", "", "", "95.2"]} +{"pcdb_id": 17434, "brand_name": "Ravenheat", "model_name": "CS 90 (T)", "model_qualifier": "Natural Gas", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 86.7, "comparative_hot_water_efficiency_pct": 68.6, "output_kw_max": 23.9, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0065, "loss_factor_f1_kwh_per_day": 1.49867, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017434", "000026", "0", "2015/May/06 11:50", "Ravenheat Manufacturing", "Ravenheat", "CS 90 (T)", "Natural Gas", "", "2015", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "23.9", "23.9", "", "", "88.1", "86.7", "", "68.6", "", "2", "", "", "104", "1", "2", "160", "3", "0", "", "", "", "0", "", "", "", "", "1", "7.674", "0.129", "0.0065", "1.49867", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "96.9", "", "", "", "", "95.2"]} +{"pcdb_id": 17435, "brand_name": "Firebird", "model_name": "Enviromax Kitchen", "model_qualifier": "C12/18kW", "winter_efficiency_pct": 89.5, "summer_efficiency_pct": 81.7, "comparative_hot_water_efficiency_pct": 59.7, "output_kw_max": 18.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017435", "000047", "0", "2015/Mar/05 11:16", "Firebird Heating Solutions Ltd", "Firebird", "Enviromax Kitchen", "C12/18kW", "", "2011", "current", "4", "1", "1", "1", "0", "", "", "2", "2", "1", "12", "18", "", "", "89.5", "81.7", "", "59.7", "", "2", "", "", "201", "1", "1", "38", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "92.7", "97.8", "", "", "", "", "96.8"]} +{"pcdb_id": 17436, "brand_name": "Firebird", "model_name": "Blue Flame Enviromax Popular", "model_qualifier": "26kW", "winter_efficiency_pct": 89.7, "summer_efficiency_pct": 81.9, "comparative_hot_water_efficiency_pct": 59.8, "output_kw_max": 26.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017436", "000047", "0", "2015/Mar/05 11:16", "Firebird Heating Solutions Ltd", "Firebird", "Blue Flame Enviromax Popular", "26kW", "", "2014", "current", "4", "1", "1", "1", "0", "", "", "2", "2", "1", "26", "26", "", "", "89.7", "81.9", "", "59.8", "", "2", "", "", "201", "1", "1", "38", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "94.2", "97.6", "", "", "", "", "97.0"]} +{"pcdb_id": 17437, "brand_name": "Sime", "model_name": "Murelle Elite HE 35 ErP", "model_qualifier": "", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 86.8, "comparative_hot_water_efficiency_pct": 69.1, "output_kw_max": 34.1, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0054, "loss_factor_f1_kwh_per_day": 1.46283, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017437", "000213", "0", "2015/Jun/12 09:59", "Fonderie Sime S.p.A.", "Sime", "Murelle Elite HE 35 ErP", "", "47-283-71", "2015", "current", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "34.1", "34.1", "", "", "87.9", "86.8", "", "69.1", "", "2", "", "", "104", "1", "2", "93", "", "0", "", "", "", "0", "", "", "", "", "1", "7.62", "0.107", "0.0054", "1.46283", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "96.4", "", "", "", "", "94.9"]} +{"pcdb_id": 17438, "brand_name": "Sime", "model_name": "Murelle Elite HE 35 ErP", "model_qualifier": "", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 88.7, "comparative_hot_water_efficiency_pct": 70.8, "output_kw_max": 34.1, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0046, "loss_factor_f1_kwh_per_day": 1.44824, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017438", "000213", "0", "2018/Jul/11 10:01", "Fonderie Sime S.p.A.", "Sime", "Murelle Elite HE 35 ErP", "", "47-283-71", "2015", "2018", "2", "2", "1", "2", "0", "", "", "2", "3", "2", "34.1", "34.1", "", "", "88.9", "88.7", "", "70.8", "", "2", "1", "", "104", "1", "2", "93", "4.3", "0", "", "", "", "0", "", "", "", "", "1", "7.6", "0.11", "0.0046", "1.44824", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.3", "98.5", "", "", "", "", "97.0"]} +{"pcdb_id": 17439, "brand_name": "Sime", "model_name": "Murelle Elite HE 35 T ErP", "model_qualifier": "", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 78.9, "comparative_hot_water_efficiency_pct": 57.6, "output_kw_max": 34.1, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017439", "000213", "0", "2015/May/05 09:20", "Fonderie Sime S.p.A.", "Sime", "Murelle Elite HE 35 T ErP", "", "41-283-54", "2015", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "34.1", "34.1", "", "", "87.9", "78.9", "", "57.6", "", "2", "", "", "102", "1", "2", "93", "4.3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "96.4", "", "", "", "", "94.9"]} +{"pcdb_id": 17442, "brand_name": "Sime", "model_name": "Murelle Elite HE 35 T ErP", "model_qualifier": "", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 34.1, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017442", "000213", "0", "2018/Jul/11 10:02", "Fonderie Sime S.p.A.", "Sime", "Murelle Elite HE 35 T ErP", "", "41-283-54", "2015", "2018", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "34.1", "34.1", "", "", "88.9", "79.9", "", "58.4", "", "2", "1", "", "102", "1", "2", "93", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.3", "98.5", "", "", "", "", "97.0"]} +{"pcdb_id": 17444, "brand_name": "Sime", "model_name": "Murelle Elite HE 30 ErP", "model_qualifier": "", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 86.8, "comparative_hot_water_efficiency_pct": 70.3, "output_kw_max": 28.9, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0061, "loss_factor_f1_kwh_per_day": 1.33382, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017444", "000213", "0", "2015/Jun/12 10:05", "Fonderie Sime S.p.A.", "Sime", "Murelle Elite HE 30 ErP", "", "", "2015", "current", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "28.9", "28.9", "", "", "87.9", "86.8", "", "70.3", "", "2", "", "", "104", "1", "2", "83", "4.3", "0", "", "", "", "0", "", "", "", "", "1", "7.49", "0.11", "0.0061", "1.33382", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "96.4", "", "", "", "", "94.9"]} +{"pcdb_id": 17446, "brand_name": "Sime", "model_name": "Murelle Elite HE 30 ErP", "model_qualifier": "", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 88.7, "comparative_hot_water_efficiency_pct": 71.5, "output_kw_max": 28.9, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0059, "loss_factor_f1_kwh_per_day": 1.37322, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017446", "000213", "0", "2018/Jul/11 09:59", "Fonderie Sime S.p.A.", "Sime", "Murelle Elite HE 30 ErP", "", "47-283-70", "2015", "2018", "2", "2", "1", "2", "0", "", "", "2", "3", "2", "28.9", "28.9", "", "", "88.9", "88.7", "", "71.5", "", "2", "1", "", "104", "1", "2", "83", "", "0", "", "", "", "0", "", "", "", "", "1", "7.53", "0.104", "0.0059", "1.37322", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.3", "98.5", "", "", "", "", "97.0"]} +{"pcdb_id": 17448, "brand_name": "Sime", "model_name": "Murelle Elite HE 25 ErP", "model_qualifier": "", "winter_efficiency_pct": 87.8, "summer_efficiency_pct": 86.6, "comparative_hot_water_efficiency_pct": 71.6, "output_kw_max": 23.9, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0053, "loss_factor_f1_kwh_per_day": 1.20125, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017448", "000213", "0", "2018/Jul/11 09:58", "Fonderie Sime S.p.A.", "Sime", "Murelle Elite HE 25 ErP", "", "", "2015", "2018", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "23.9", "23.9", "", "", "87.8", "86.6", "", "71.6", "", "2", "", "", "104", "1", "2", "84", "4.3", "0", "", "", "", "0", "", "", "", "", "1", "7.36", "0.101", "0.0053", "1.20125", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "96.4", "", "", "", "", "94.8"]} +{"pcdb_id": 17449, "brand_name": "Sime", "model_name": "Murelle Elite HE 25 ErP", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 88.6, "comparative_hot_water_efficiency_pct": 73.2, "output_kw_max": 23.9, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0057, "loss_factor_f1_kwh_per_day": 1.189, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017449", "000213", "0", "2018/Jul/11 09:59", "Fonderie Sime S.p.A.", "Sime", "Murelle Elite HE 25 ErP", "", "", "2015", "2018", "2", "2", "1", "2", "0", "", "", "2", "3", "2", "23.9", "23.9", "", "", "88.8", "88.6", "", "73.2", "", "2", "1", "", "104", "1", "2", "84", "4.3", "0", "", "", "", "0", "", "", "", "", "1", "7.35", "0.106", "0.0057", "1.189", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.8", "98.5", "", "", "", "", "96.9"]} +{"pcdb_id": 17450, "brand_name": "Sime", "model_name": "Murelle PRO HE 40 R IE ErP", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 39.1, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017450", "000213", "0", "2018/Jul/11 11:25", "Fonderie Sime S.p.A.", "Sime", "Murelle PRO HE 40 R IE ErP", "", "", "2015", "2018", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "39.1", "39.1", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "111", "3.6", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.7", "96.4", "", "", "", "", "95.0"]} +{"pcdb_id": 17451, "brand_name": "Sime", "model_name": "Murelle PRO HE 40 R IE ErP", "model_qualifier": "", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 39.1, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017451", "000213", "0", "2018/Jul/11 11:26", "Fonderie Sime S.p.A.", "Sime", "Murelle PRO HE 40 R IE ErP", "", "", "2015", "2018", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "39.1", "39.1", "", "", "89.0", "80.0", "", "58.4", "", "2", "1", "", "102", "1", "2", "111", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.7", "98.5", "", "", "", "", "97.1"]} +{"pcdb_id": 17452, "brand_name": "Sime", "model_name": "Murelle PRO HE 35 R IE ErP", "model_qualifier": "", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 78.9, "comparative_hot_water_efficiency_pct": 57.6, "output_kw_max": 34.1, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017452", "000213", "0", "2018/Jul/11 11:25", "Fonderie Sime S.p.A.", "Sime", "Murelle PRO HE 35 R IE ErP", "", "", "2015", "2018", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "34.1", "34.1", "", "", "87.9", "78.9", "", "57.6", "", "2", "", "", "102", "1", "2", "92", "3.6", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.4", "96.4", "", "", "", "", "94.9"]} +{"pcdb_id": 17453, "brand_name": "Sime", "model_name": "Murelle PRO HE 35 R IE ErP", "model_qualifier": "", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 34.1, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017453", "000213", "0", "2018/Jul/11 11:25", "Fonderie Sime S.p.A.", "Sime", "Murelle PRO HE 35 R IE ErP", "", "", "2015", "2018", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "34.1", "34.1", "", "", "88.9", "79.9", "", "58.4", "", "2", "1", "", "102", "1", "2", "92", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.4", "98.5", "", "", "", "", "97.0"]} +{"pcdb_id": 17454, "brand_name": "Sime", "model_name": "Murelle PRO HE 30 R IE ErP", "model_qualifier": "", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 78.9, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 29.5, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017454", "000213", "0", "2018/Jul/11 11:24", "Fonderie Sime S.p.A.", "Sime", "Murelle PRO HE 30 R IE ErP", "", "", "2015", "2018", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "29.5", "29.5", "", "", "87.9", "78.9", "", "57.7", "", "2", "", "", "102", "1", "2", "78", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.6", "96.4", "", "", "", "", "94.9"]} +{"pcdb_id": 17455, "brand_name": "Sime", "model_name": "Murelle PRO HE 30 R IE ErP", "model_qualifier": "", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 29.5, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017455", "000213", "0", "2018/Jul/11 11:24", "Fonderie Sime S.p.A.", "Sime", "Murelle PRO HE 30 R IE ErP", "", "", "2015", "2018", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "29.5", "29.5", "", "", "88.9", "79.9", "", "58.4", "", "2", "1", "", "102", "1", "2", "78", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.5", "98.5", "", "", "", "", "97.0"]} +{"pcdb_id": 17456, "brand_name": "Sime", "model_name": "Murelle PRO HE 30 IE ErP", "model_qualifier": "", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 86.9, "comparative_hot_water_efficiency_pct": 73.2, "output_kw_max": 23.6, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0051, "loss_factor_f1_kwh_per_day": 1.05776, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017456", "000213", "0", "2018/Jul/11 11:21", "Fonderie Sime S.p.A.", "Sime", "Murelle PRO HE 30 IE ErP", "", "", "2015", "2018", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "23.6", "23.6", "", "", "87.9", "86.9", "", "73.2", "", "2", "", "", "104", "1", "2", "85", "3.6", "0", "", "", "", "0", "", "", "", "", "1", "7.19", "0.115", "0.0051", "1.05776", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.6", "96.4", "", "", "", "", "94.9"]} +{"pcdb_id": 17457, "brand_name": "Sime", "model_name": "Murelle PRO HE 30 IE ErP", "model_qualifier": "", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 88.8, "comparative_hot_water_efficiency_pct": 74.5, "output_kw_max": 23.6, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.004, "loss_factor_f1_kwh_per_day": 1.10276, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017457", "000213", "0", "2018/Jul/11 11:21", "Fonderie Sime S.p.A.", "Sime", "Murelle PRO HE 30 IE ErP", "", "", "2015", "2018", "2", "2", "1", "2", "0", "", "", "2", "3", "2", "23.6", "23.6", "", "", "88.9", "88.8", "", "74.5", "", "2", "1", "", "104", "1", "2", "85", "", "0", "", "", "", "0", "", "", "", "", "1", "7.23", "0.111", "0.004", "1.10276", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.5", "98.5", "", "", "", "", "97.0"]} +{"pcdb_id": 17458, "brand_name": "Sime", "model_name": "Murelle PRO HE 25 R IE ErP", "model_qualifier": "", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 78.9, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 23.6, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017458", "000213", "0", "2018/Jul/11 11:16", "Fonderie Sime S.p.A.", "Sime", "Murelle PRO HE 25 R IE ErP", "", "", "2015", "2018", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "23.6", "23.6", "", "", "87.9", "78.9", "", "57.7", "", "2", "", "", "102", "1", "2", "73", "3.6", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.6", "96.4", "", "", "", "", "94.9"]} +{"pcdb_id": 17459, "brand_name": "Sime", "model_name": "Murelle PRO HE 25 R IE ErP", "model_qualifier": "", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 23.6, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017459", "000213", "0", "2018/Jul/11 11:18", "Fonderie Sime S.p.A.", "Sime", "Murelle PRO HE 25 R IE ErP", "", "", "2015", "2018", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "23.6", "23.6", "", "", "88.9", "79.9", "", "58.4", "", "2", "1", "", "102", "1", "2", "73", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.5", "98.5", "", "", "", "", "97.0"]} +{"pcdb_id": 17460, "brand_name": "Sime", "model_name": "Murelle PRO HE 30 R ErP", "model_qualifier": "", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 78.9, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 29.5, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017460", "000213", "0", "2018/Jul/11 11:22", "Fonderie Sime S.p.A.", "Sime", "Murelle PRO HE 30 R ErP", "", "", "2015", "2018", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "29.5", "29.5", "", "", "87.9", "78.9", "", "57.7", "", "2", "", "", "102", "1", "2", "78", "3.6", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.6", "96.4", "", "", "", "", "94.9"]} +{"pcdb_id": 17461, "brand_name": "Sime", "model_name": "Murelle PRO HE 30 R ErP", "model_qualifier": "", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 29.5, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017461", "000213", "0", "2018/Jul/11 11:23", "Fonderie Sime S.p.A.", "Sime", "Murelle PRO HE 30 R ErP", "", "", "2015", "2018", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "29.5", "29.5", "", "", "88.9", "79.9", "", "58.4", "", "2", "1", "", "102", "1", "2", "78", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.5", "98.5", "", "", "", "", "97.0"]} +{"pcdb_id": 17462, "brand_name": "Sime", "model_name": "Murelle PRO HE 30 ErP", "model_qualifier": "", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 86.9, "comparative_hot_water_efficiency_pct": 73.2, "output_kw_max": 23.6, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0051, "loss_factor_f1_kwh_per_day": 1.05776, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017462", "000213", "0", "2018/Jul/11 11:20", "Fonderie Sime S.p.A.", "Sime", "Murelle PRO HE 30 ErP", "", "47-283-66", "2015", "2018", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "23.6", "23.6", "", "", "87.9", "86.9", "", "73.2", "", "2", "", "", "104", "1", "2", "85", "3.6", "0", "", "", "", "0", "", "", "", "", "1", "7.19", "0.115", "0.0051", "1.05776", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.6", "96.4", "", "", "", "", "94.9"]} +{"pcdb_id": 17463, "brand_name": "Sime", "model_name": "Murelle PRO HE 30 ErP", "model_qualifier": "", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 88.8, "comparative_hot_water_efficiency_pct": 74.5, "output_kw_max": 23.6, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.004, "loss_factor_f1_kwh_per_day": 1.10276, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017463", "000213", "0", "2018/Jul/11 11:20", "Fonderie Sime S.p.A.", "Sime", "Murelle PRO HE 30 ErP", "", "47-283-66", "2015", "2018", "2", "2", "1", "2", "0", "", "", "2", "3", "2", "23.6", "23.6", "", "", "88.9", "88.8", "", "74.5", "", "2", "1", "", "104", "1", "2", "85", "", "0", "", "", "0", "0", "", "", "", "", "1", "7.23", "0.111", "0.004", "1.10276", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.5", "98.5", "", "", "", "", "97.0"]} +{"pcdb_id": 17464, "brand_name": "Sime", "model_name": "Murelle PRO HE 25 LPG ErP", "model_qualifier": "", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 88.8, "comparative_hot_water_efficiency_pct": 70.6, "output_kw_max": 19.7, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.008, "loss_factor_f1_kwh_per_day": 1.4554, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017464", "000213", "0", "2018/Jul/11 11:15", "Fonderie Sime S.p.A.", "Sime", "Murelle PRO HE 25 LPG ErP", "", "", "2015", "2018", "2", "2", "1", "2", "0", "", "", "2", "3", "2", "19.7", "19.7", "", "", "88.9", "88.8", "", "70.6", "", "2", "1", "", "104", "1", "2", "70", "3.6", "0", "", "", "", "0", "", "", "", "", "1", "7.62", "0.108", "0.008", "1.4554", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.5", "98.5", "", "", "", "", "97.0"]} +{"pcdb_id": 17465, "brand_name": "Sime", "model_name": "Murelle PRO HE 25 HO ErP", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 23.6, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017465", "000213", "0", "2018/Jul/11 11:09", "Fonderie Sime S.p.A.", "Sime", "Murelle PRO HE 25 HO ErP", "", "41-283-53", "2015", "2018", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "23.6", "23.6", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "34", "3.6", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.7", "96.4", "", "", "", "", "95.0"]} +{"pcdb_id": 17466, "brand_name": "Sime", "model_name": "Murelle PRO HE 25 HO ErP", "model_qualifier": "", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 23.6, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017466", "000213", "0", "2018/Jul/11 11:15", "Fonderie Sime S.p.A.", "Sime", "Murelle PRO HE 25 HO ErP", "", "41-283-53", "2015", "2018", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "23.6", "23.6", "", "", "89.0", "80.0", "", "58.4", "", "2", "1", "", "102", "1", "2", "34", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.7", "98.5", "", "", "", "", "97.1"]} +{"pcdb_id": 17467, "brand_name": "Sime", "model_name": "Murelle PRO HE 25 ErP", "model_qualifier": "", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 86.9, "comparative_hot_water_efficiency_pct": 68.8, "output_kw_max": 19.7, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.007, "loss_factor_f1_kwh_per_day": 1.48988, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017467", "000213", "0", "2018/Jul/11 11:05", "Fonderie Sime S.p.A.", "Sime", "Murelle PRO HE 25 ErP", "", "", "2015", "2018", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "19.7", "19.7", "", "", "87.9", "86.9", "", "68.8", "", "2", "", "", "104", "1", "2", "70", "3.6", "0", "", "", "", "0", "", "", "", "", "1", "7.65", "0.105", "0.007", "1.48988", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.6", "96.4", "", "", "", "", "94.9"]} +{"pcdb_id": 17468, "brand_name": "Sime", "model_name": "Murelle PRO HE 25 ErP", "model_qualifier": "", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 88.8, "comparative_hot_water_efficiency_pct": 70.6, "output_kw_max": 19.7, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.008, "loss_factor_f1_kwh_per_day": 1.4554, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017468", "000213", "0", "2018/Jul/11 11:06", "Fonderie Sime S.p.A.", "Sime", "Murelle PRO HE 25 ErP", "", "47-283-65", "2015", "2018", "2", "2", "1", "2", "0", "", "", "2", "3", "2", "19.7", "19.7", "", "", "88.9", "88.8", "", "70.6", "", "2", "1", "", "104", "1", "2", "70", "", "0", "", "", "", "0", "", "", "", "", "1", "7.62", "0.108", "0.008", "1.4554", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.5", "98.5", "", "", "", "", "97.0"]} +{"pcdb_id": 17469, "brand_name": "Sime", "model_name": "Murelle PRO HE 20 R ErP", "model_qualifier": "", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 78.9, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 19.7, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017469", "000213", "0", "2018/Jul/11 11:03", "Fonderie Sime S.p.A.", "Sime", "Murelle PRO HE 20 R ErP", "", "41-283-51", "2015", "2018", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "19.7", "19.7", "", "", "87.9", "78.9", "", "57.7", "", "2", "", "", "102", "1", "2", "65", "3.6", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.6", "96.4", "", "", "", "", "94.9"]} +{"pcdb_id": 17470, "brand_name": "Sime", "model_name": "Murelle PRO HE 20 R ErP", "model_qualifier": "", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 19.7, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017470", "000213", "0", "2018/Jul/11 11:04", "Fonderie Sime S.p.A.", "Sime", "Murelle PRO HE 20 R ErP", "", "41-283-51", "2015", "2018", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "19.7", "19.7", "", "", "88.9", "79.9", "", "58.4", "", "2", "1", "", "102", "1", "2", "65", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.5", "98.5", "", "", "", "", "97.0"]} +{"pcdb_id": 17471, "brand_name": "Sime", "model_name": "Murelle Advanced HE 40 ErP", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 87.0, "comparative_hot_water_efficiency_pct": 65.8, "output_kw_max": 34.5, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0056, "loss_factor_f1_kwh_per_day": 1.84143, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017471", "000213", "0", "2018/Jul/11 09:51", "Fonderie Sime S.p.A.", "Sime", "Murelle Advanced HE 40 ErP", "", "47-283-69", "2015", "2018", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "34.5", "34.5", "", "", "88.0", "87.0", "", "65.8", "", "2", "", "", "104", "1", "2", "111", "", "0", "", "", "", "0", "", "", "", "", "1", "7.998", "0.108", "0.0056", "1.84143", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.8", "96.4", "", "", "", "", "95.0"]} +{"pcdb_id": 17472, "brand_name": "Sime", "model_name": "Murelle Advanced HE 40 ErP", "model_qualifier": "", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 88.9, "comparative_hot_water_efficiency_pct": 67.0, "output_kw_max": 34.5, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0055, "loss_factor_f1_kwh_per_day": 1.87319, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017472", "000213", "0", "2018/Jul/11 09:52", "Fonderie Sime S.p.A.", "Sime", "Murelle Advanced HE 40 ErP", "", "47-283-69", "2015", "2018", "2", "2", "1", "2", "0", "", "", "2", "3", "2", "34.5", "34.5", "", "", "89.0", "88.9", "", "67.0", "", "2", "1", "", "104", "1", "2", "111", "3.6", "0", "", "", "", "0", "", "", "", "", "1", "8.03", "0.111", "0.0055", "1.87319", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.8", "98.5", "", "", "", "", "97.1"]} +{"pcdb_id": 17473, "brand_name": "Sime", "model_name": "Murelle Advanced HE 30 ErP", "model_qualifier": "", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 86.9, "comparative_hot_water_efficiency_pct": 69.0, "output_kw_max": 23.6, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0058, "loss_factor_f1_kwh_per_day": 1.4779, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017473", "000213", "0", "2018/Jul/11 09:50", "Fonderie Sime S.p.A.", "Sime", "Murelle Advanced HE 30 ErP", "", "47-283-68", "2015", "2018", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "23.6", "23.6", "", "", "87.9", "86.9", "", "69.0", "", "2", "", "", "104", "1", "2", "85", "3.6", "0", "", "", "", "0", "", "", "", "", "1", "7.63", "0.118", "0.0058", "1.4779", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.6", "96.4", "", "", "", "", "94.9"]} +{"pcdb_id": 17474, "brand_name": "Sime", "model_name": "Murelle Advanced HE 30 ErP", "model_qualifier": "", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 88.8, "comparative_hot_water_efficiency_pct": 70.6, "output_kw_max": 23.6, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0059, "loss_factor_f1_kwh_per_day": 1.47732, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017474", "000213", "0", "2018/Jul/11 09:50", "Fonderie Sime S.p.A.", "Sime", "Murelle Advanced HE 30 ErP", "", "47-283-68", "2015", "2018", "2", "2", "1", "2", "0", "", "", "2", "3", "2", "23.6", "23.6", "", "", "88.9", "88.8", "", "70.6", "", "2", "1", "", "104", "1", "2", "85", "", "0", "", "", "", "0", "", "", "", "", "1", "7.63", "0.122", "0.0059", "1.47732", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.5", "98.5", "", "", "", "", "97.0"]} +{"pcdb_id": 17475, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "9i System ErP LPG", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 9.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017475", "000035", "0", "2017/May/15 15:31", "Bosch Thermotechnology", "Worcester", "Greenstar", "9i System ErP LPG", "41-406-22", "2015", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "9.0", "9.0", "", "", "89.1", "80.1", "", "58.5", "", "2", "0", "0", "102", "1", "2", "95", "1.7", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "8325", "", "", "", "", "", "", "", "", "89.2", "97.0", "", "", "", "", "95.5"]} +{"pcdb_id": 17476, "brand_name": "Ideal", "model_name": "INSTINCT", "model_qualifier": "24", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 62.2, "output_kw_max": 24.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017476", "000008", "0", "2015/Apr/20 13:08", "Ideal Boilers", "Ideal", "INSTINCT", "24", "47-349-09", "2015", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "88.3", "79.7", "", "62.2", "", "2", "", "", "104", "1", "2", "146", "1", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "", "0035", "", "", "", "", "", "", "", "", "89.8", "96.9", "", "", "", "", "95.5"]} +{"pcdb_id": 17477, "brand_name": "Ideal", "model_name": "INSTINCT", "model_qualifier": "30", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 62.3, "output_kw_max": 24.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017477", "000008", "0", "2015/Apr/20 13:06", "Ideal Boilers", "Ideal", "INSTINCT", "30", "47-349-10", "2015", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "88.4", "79.8", "", "62.3", "", "2", "", "", "104", "1", "2", "152", "1", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "", "0035", "", "", "", "", "", "", "", "", "90.0", "96.9", "", "", "", "", "95.6"]} +{"pcdb_id": 17478, "brand_name": "Ideal", "model_name": "INSTINCT", "model_qualifier": "35", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 62.3, "output_kw_max": 24.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017478", "000008", "0", "2015/Apr/20 13:07", "Ideal Boilers", "Ideal", "INSTINCT", "35", "47-349-11", "2015", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "88.4", "79.8", "", "62.3", "", "2", "", "", "104", "1", "2", "177", "1", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "", "0035", "", "", "", "", "", "", "", "", "89.8", "96.9", "", "", "", "", "95.6"]} +{"pcdb_id": 17479, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "9i System ErP", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 9.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017479", "000035", "0", "2015/May/06 14:33", "Bosch Thermotechnology", "Worcester", "Greenstar", "9i System ErP", "41-406-21", "2015", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "9", "9", "", "", "89.1", "80.1", "", "58.5", "", "2", "", "", "102", "1", "2", "94", "1.7", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "8325", "", "", "", "", "", "", "", "", "88.3", "99.6", "", "", "", "", "97.4"]} +{"pcdb_id": 17480, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "12i System ErP LPG", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 12.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017480", "000035", "0", "2017/May/15 15:31", "Bosch Thermotechnology", "Worcester", "Greenstar", "12i System ErP LPG", "41-406-24", "2015", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "12.0", "12.0", "", "", "89.1", "80.1", "", "58.5", "", "2", "0", "0", "102", "1", "2", "109", "1.7", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "8325", "", "", "", "", "", "", "", "", "89.2", "97.0", "", "", "", "", "95.5"]} +{"pcdb_id": 17481, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "12i System ErP", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 12.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017481", "000035", "0", "2015/May/06 13:18", "Bosch Thermotechnology", "Worcester", "Greenstar", "12i System ErP", "41-406-23", "2015", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "12.0", "12.0", "", "", "89.1", "80.1", "", "58.5", "", "2", "", "", "102", "1", "2", "107", "1.7", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "8325", "", "", "", "", "", "", "", "", "88.3", "99.6", "", "", "", "", "97.4"]} +{"pcdb_id": 17482, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "15i System ErP LPG", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 15.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017482", "000035", "0", "2017/May/15 15:31", "Bosch Thermotechnology", "Worcester", "Greenstar", "15i System ErP LPG", "41-406-26", "2015", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "15.0", "15.0", "", "", "88.4", "79.4", "", "58.0", "", "2", "0", "0", "102", "1", "2", "105", "1.7", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "8325", "", "", "", "", "", "", "", "", "89.4", "95.0", "", "", "", "", "94.0"]} +{"pcdb_id": 17483, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "15i System ErP", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 15.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017483", "000035", "0", "2015/May/06 13:19", "Bosch Thermotechnology", "Worcester", "Greenstar", "15i System ErP", "41-406-25", "2015", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "15.0", "15.0", "", "", "89.0", "80.0", "", "58.4", "", "2", "", "", "102", "1", "2", "102", "1.7", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "8325", "", "", "", "", "", "", "", "", "87.9", "99.4", "", "", "", "", "97.2"]} +{"pcdb_id": 17484, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "18i System ErP LPG", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 18.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017484", "000035", "0", "2017/May/15 15:31", "Bosch Thermotechnology", "Worcester", "Greenstar", "18i System ErP LPG", "41-406-28", "2015", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "18.0", "18.0", "", "", "88.4", "79.4", "", "58.0", "", "2", "0", "0", "102", "1", "2", "119", "1.7", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "8325", "", "", "", "", "", "", "", "", "89.4", "95.0", "", "", "", "", "94.0"]} +{"pcdb_id": 17485, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "18i System ErP", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 18.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017485", "000035", "0", "2015/May/06 13:20", "Bosch Thermotechnology", "Worcester", "Greenstar", "18i System ErP", "41-406-27", "2015", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18.0", "18.0", "", "", "89.0", "80.0", "", "58.4", "", "2", "", "", "102", "1", "2", "117", "1.7", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "8325", "", "", "", "", "", "", "", "", "87.9", "99.4", "", "", "", "", "97.2"]} +{"pcdb_id": 17486, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "21i System ErP LPG", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 21.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017486", "000035", "0", "2017/May/15 15:31", "Bosch Thermotechnology", "Worcester", "Greenstar", "21i System ErP LPG", "41-406-30", "2015", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "21.0", "21.0", "", "", "88.4", "79.4", "", "58.0", "", "2", "0", "0", "102", "1", "2", "107", "1.7", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "8325", "", "", "", "", "", "", "", "", "89.7", "95.0", "", "", "", "", "94.0"]} +{"pcdb_id": 17487, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "21i System ErP", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 21.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017487", "000035", "0", "2015/May/06 13:21", "Bosch Thermotechnology", "Worcester", "Greenstar", "21i System ErP", "41-406-29", "2015", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "21.0", "21.0", "", "", "89.0", "80.0", "", "58.4", "", "2", "", "", "102", "1", "2", "102", "1.7", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "8325", "", "", "", "", "", "", "", "", "87.8", "99.5", "", "", "", "", "97.2"]} +{"pcdb_id": 17488, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "24i System ErP LPG", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 24.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017488", "000035", "0", "2017/May/15 15:31", "Bosch Thermotechnology", "Worcester", "Greenstar", "24i System ErP LPG", "41-406-32", "2015", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "24", "24", "", "", "88.4", "79.4", "", "58.0", "", "2", "0", "0", "102", "1", "2", "109", "1.7", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "8325", "", "", "", "", "", "", "", "", "89.7", "95.0", "", "", "", "", "94.0"]} +{"pcdb_id": 17489, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "24i System ErP", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 24.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017489", "000035", "0", "2015/May/06 13:21", "Bosch Thermotechnology", "Worcester", "Greenstar", "24i System ErP", "41-406-31", "2015", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24", "24", "", "", "89.0", "80.0", "", "58.4", "", "2", "", "", "102", "1", "2", "106", "1.7", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "8325", "", "", "", "", "", "", "", "", "87.8", "99.5", "", "", "", "", "97.2"]} +{"pcdb_id": 17490, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "27i System Compact ErP LPG", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 27.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017490", "000035", "0", "2018/Jan/26 14:11", "Bosch Thermotechnology", "Worcester", "Greenstar", "27i System Compact ErP LPG", "41-406-59", "2015", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "27", "27", "", "", "89.2", "80.2", "", "58.6", "", "2", "0", "0", "102", "1", "2", "102", "1", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "8325", "", "", "", "", "", "", "", "", "90.2", "96.8", "", "", "", "", "95.5"]} +{"pcdb_id": 17491, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "27i System Compact ErP", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 27.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017491", "000035", "0", "2015/Apr/15 14:33", "Bosch Thermotechnology", "Worcester", "Greenstar", "27i System Compact ErP", "41-406-58", "2015", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "27", "27", "", "", "88.3", "79.3", "", "57.9", "", "2", "", "", "102", "1", "2", "102", "1", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "8325", "", "", "", "", "", "", "", "", "88.2", "97.4", "", "", "", "", "95.7"]} +{"pcdb_id": 17492, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "30i System Compact ErP LPG", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 30.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017492", "000035", "0", "2018/Jan/26 14:11", "Bosch Thermotechnology", "Worcester", "Greenstar", "30i System Compact ErP LPG", "41-406-61", "2015", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "30", "30", "", "", "89.2", "80.2", "", "58.6", "", "2", "0", "0", "102", "1", "2", "109", "1", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "8325", "", "", "", "", "", "", "", "", "90.2", "96.8", "", "", "", "", "95.5"]} +{"pcdb_id": 17493, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "30i System Compact ErP", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 30.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017493", "000035", "0", "2015/Apr/15 14:40", "Bosch Thermotechnology", "Worcester", "Greenstar", "30i System Compact ErP", "41-406-60", "2015", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "30", "30", "", "", "88.3", "79.3", "", "57.9", "", "2", "", "", "102", "1", "2", "109", "1", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "8325", "", "", "", "", "", "", "", "", "88.2", "97.4", "", "", "", "", "95.7"]} +{"pcdb_id": 17495, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "27Ri Compact ErP LPG", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 27.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017495", "000035", "0", "2018/Jan/26 14:11", "Bosch Thermotechnology", "Worcester", "Greenstar", "27Ri Compact ErP LPG", "41-406-55", "2015", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "27", "27", "", "", "89.2", "80.2", "", "58.6", "", "2", "0", "0", "102", "1", "2", "33", "1", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0325", "", "", "", "", "", "", "", "", "90.2", "96.8", "", "", "", "", "95.5"]} +{"pcdb_id": 17496, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "27Ri Compact ErP", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 27.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017496", "000035", "0", "2018/Jan/26 14:11", "Bosch Thermotechnology", "Worcester", "Greenstar", "27Ri Compact ErP", "41-406-54", "2015", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "27", "27", "", "", "88.3", "79.3", "", "57.9", "", "2", "", "", "102", "1", "2", "34", "1", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0325", "", "", "", "", "", "", "", "", "88.2", "97.4", "", "", "", "", "95.7"]} +{"pcdb_id": 17497, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "30Ri Compact ErP LPG", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 30.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017497", "000035", "0", "2018/Jan/26 14:11", "Bosch Thermotechnology", "Worcester", "Greenstar", "30Ri Compact ErP LPG", "41-406-57", "2015", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "30", "30", "", "", "89.2", "80.2", "", "58.6", "", "2", "0", "0", "102", "1", "2", "39", "1", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0325", "", "", "", "", "", "", "", "", "90.2", "96.8", "", "", "", "", "95.5"]} +{"pcdb_id": 17498, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "30Ri Compact ErP", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 30.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017498", "000035", "0", "2018/Jan/26 14:11", "Bosch Thermotechnology", "Worcester", "Greenstar", "30Ri Compact ErP", "41-406-56", "2015", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "30", "30", "", "", "88.3", "79.3", "", "57.9", "", "2", "", "", "102", "1", "2", "40", "1", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0325", "", "", "", "", "", "", "", "", "88.2", "97.4", "", "", "", "", "95.7"]} +{"pcdb_id": 17500, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "25Si Compact ErP LPG", "winter_efficiency_pct": 89.8, "summer_efficiency_pct": 88.8, "comparative_hot_water_efficiency_pct": 75.8, "output_kw_max": 24.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0013, "loss_factor_f1_kwh_per_day": 0.99038, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017500", "000035", "0", "2020/Jul/17 10:33", "Bosch Thermotechnology", "Worcester", "Greenstar", "25Si Compact ErP LPG", "47-406-74", "2015", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "89.8", "88.8", "", "75.8", "", "2", "0", "", "104", "1", "2", "97", "1", "0", "", "", "", "0", "", "", "", "", "1", "7.1", "0.09", "0.0013", "0.99038", "", "", "", "", "", "1", "1", "", "8325", "", "", "", "", "", "", "", "", "90.4", "98.2", "", "", "", "", "96.7"]} +{"pcdb_id": 17501, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "25Si Compact ErP", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 87.0, "comparative_hot_water_efficiency_pct": 74.7, "output_kw_max": 24.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0015, "loss_factor_f1_kwh_per_day": 0.95138, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017501", "000035", "0", "2020/Jul/17 10:39", "Bosch Thermotechnology", "Worcester", "Greenstar", "25Si Compact ErP", "47-406-73", "2015", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "89.2", "87.0", "", "74.7", "", "2", "", "", "104", "1", "2", "97", "1", "0", "", "", "", "0", "", "", "", "", "1", "7.051", "0.08", "0.0015", "0.95138", "", "", "", "", "", "1", "1", "", "8325", "", "", "", "", "", "", "", "", "88.8", "99.6", "", "", "", "", "97.5"]} +{"pcdb_id": 17502, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "30Si Compact ErP LPG", "winter_efficiency_pct": 89.8, "summer_efficiency_pct": 88.8, "comparative_hot_water_efficiency_pct": 75.2, "output_kw_max": 24.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0013, "loss_factor_f1_kwh_per_day": 1.04824, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017502", "000035", "0", "2020/Jul/17 11:16", "Bosch Thermotechnology", "Worcester", "Greenstar", "30Si Compact ErP LPG", "47-406-76", "2015", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "89.8", "88.8", "", "75.2", "", "2", "0", "", "104", "1", "2", "97", "1", "0", "", "", "", "0", "", "", "", "", "1", "7.16", "0.089", "0.0013", "1.04824", "", "", "", "", "", "1", "1", "", "8325", "", "", "", "", "", "", "", "", "90.4", "98.2", "", "", "", "", "96.7"]} +{"pcdb_id": 17503, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "30Si Compact ErP", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 87.0, "comparative_hot_water_efficiency_pct": 74.2, "output_kw_max": 24.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0019, "loss_factor_f1_kwh_per_day": 0.99839, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017503", "000035", "0", "2021/Nov/17 12:53", "Bosch Thermotechnology", "Worcester", "Greenstar", "30Si Compact ErP", "47-406-75", "2015", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "89.2", "87.0", "", "74.2", "", "2", "", "", "104", "1", "2", "97", "1", "0", "", "", "", "0", "", "", "", "", "1", "7.102", "0.078", "0.0019", "0.99839", "", "", "", "", "", "1", "1", "", "8325", "", "", "", "", "", "", "", "", "88.8", "99.6", "", "", "", "", "97.5"]} +{"pcdb_id": 17504, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "25i ErP LPG", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 88.6, "comparative_hot_water_efficiency_pct": 71.1, "output_kw_max": 24.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0015, "loss_factor_f1_kwh_per_day": 1.42427, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017504", "000035", "0", "2021/Nov/17 12:53", "Bosch Thermotechnology", "Worcester", "Greenstar", "25i ErP LPG", "47-406-61", "2015", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24.0", "24.0", "", "", "88.5", "88.6", "", "71.1", "", "2", "0", "0", "104", "1", "2", "109", "1.7", "0", "", "", "", "0", "", "", "", "", "1", "7.569", "0.093", "0.0015", "1.42427", "", "", "", "", "", "", "", "", "8325", "", "", "", "", "", "", "", "", "89.8", "95.0", "", "", "", "", "94.0"]} +{"pcdb_id": 17505, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "25i ErP", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 86.6, "comparative_hot_water_efficiency_pct": 73.2, "output_kw_max": 24.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0016, "loss_factor_f1_kwh_per_day": 1.05659, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017505", "000035", "0", "2020/Jul/17 11:37", "Bosch Thermotechnology", "Worcester", "Greenstar", "25i ErP", "47-406-60", "2015", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "89.0", "86.6", "", "73.2", "", "2", "", "", "104", "1", "2", "106", "1.7", "0", "", "", "", "0", "", "", "", "", "1", "7.19", "0.073", "0.0016", "1.05659", "", "", "", "", "", "1", "1", "", "8325", "", "", "", "", "", "", "", "", "87.8", "99.5", "", "", "", "", "97.2"]} +{"pcdb_id": 17506, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "30i ErP LPG", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 88.6, "comparative_hot_water_efficiency_pct": 69.7, "output_kw_max": 24.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0015, "loss_factor_f1_kwh_per_day": 1.57614, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017506", "000035", "0", "2022/Jan/05 09:48", "Bosch Thermotechnology", "Worcester", "Greenstar", "30i ErP LPG", "47-406-63", "2015", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24.0", "24.0", "", "", "88.5", "88.6", "", "69.7", "", "2", "0", "0", "104", "1", "2", "109", "1.7", "0", "", "", "", "0", "", "", "", "", "1", "7.727", "0.096", "0.0015", "1.57614", "", "", "", "", "", "", "", "", "8325", "", "", "", "", "", "", "", "", "89.8", "95.0", "", "", "", "", "94.0"]} +{"pcdb_id": 17507, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "30i ErP", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 86.6, "comparative_hot_water_efficiency_pct": 72.1, "output_kw_max": 24.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0015, "loss_factor_f1_kwh_per_day": 1.16717, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017507", "000035", "0", "2020/Jul/17 11:55", "Bosch Thermotechnology", "Worcester", "Greenstar", "30i ErP", "47-406-62", "2015", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "89.0", "86.6", "", "72.1", "", "2", "", "", "104", "1", "2", "106", "1.7", "0", "", "", "", "0", "", "", "", "", "1", "7.304", "0.076", "0.0015", "1.16717", "", "", "", "", "", "1", "1", "", "8325", "", "", "", "", "", "", "", "", "87.8", "99.5", "", "", "", "", "97.2"]} +{"pcdb_id": 17508, "brand_name": "Worcester", "model_name": "533 Compact ErP", "model_qualifier": "", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 87.0, "comparative_hot_water_efficiency_pct": 74.8, "output_kw_max": 24.0, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0015, "loss_factor_f1_kwh_per_day": 0.94279, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017508", "000035", "0", "2020/Sep/08 10:44", "Bosch Thermotechnology", "Worcester", "533 Compact ErP", "", "47-406-83", "2015", "2018", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "89.2", "87.0", "", "74.8", "", "2", "", "", "104", "1", "2", "97", "1", "0", "", "", "", "0", "", "", "", "", "1", "7.042", "0.079", "0.0015", "0.94279", "", "", "", "", "", "1", "1", "", "0005", "", "", "", "", "", "", "", "", "88.8", "99.6", "", "", "", "", "97.5"]} +{"pcdb_id": 17509, "brand_name": "Worcester", "model_name": "535 Compact ErP", "model_qualifier": "", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 87.0, "comparative_hot_water_efficiency_pct": 74.2, "output_kw_max": 24.0, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0015, "loss_factor_f1_kwh_per_day": 0.99382, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017509", "000035", "0", "2020/Sep/08 10:45", "Bosch Thermotechnology", "Worcester", "535 Compact ErP", "", "47-406-84", "2015", "2018", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "89.2", "87.0", "", "74.2", "", "2", "", "", "104", "1", "2", "97", "1", "0", "", "", "", "0", "", "", "", "", "1", "7.095", "0.079", "0.0015", "0.99382", "", "", "", "", "", "1", "1", "", "0005", "", "", "", "", "", "", "", "", "88.8", "99.6", "", "", "", "", "97.5"]} +{"pcdb_id": 17510, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "28CDi Compact ErP LPG", "winter_efficiency_pct": 89.8, "summer_efficiency_pct": 88.8, "comparative_hot_water_efficiency_pct": 74.8, "output_kw_max": 24.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0014, "loss_factor_f1_kwh_per_day": 1.08665, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017510", "000035", "0", "2020/Jul/17 11:59", "Bosch Thermotechnology", "Worcester", "Greenstar", "28CDi Compact ErP LPG", "47-406-78", "2015", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "89.8", "88.8", "", "74.8", "", "2", "0", "", "104", "1", "2", "97", "1", "0", "", "", "", "0", "", "", "", "", "1", "7.2", "0.087", "0.0014", "1.08665", "", "", "", "", "", "1", "1", "", "8325", "", "", "", "", "", "", "", "", "90.4", "98.2", "", "", "", "", "96.7"]} +{"pcdb_id": 17511, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "28CDi Compact ErP", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 87.2, "comparative_hot_water_efficiency_pct": 74.9, "output_kw_max": 24.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.0015, "loss_factor_f1_kwh_per_day": 0.93299, "loss_factor_f2_kwh_per_day": 0.81383, "rejected_factor_f3_per_litre": -1e-05, "raw": ["017511", "000035", "0", "2020/Jul/27 16:00", "Bosch Thermotechnology", "Worcester", "Greenstar", "28CDi Compact ErP", "47-406-77", "2015", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "89.2", "87.2", "", "74.9", "", "2", "", "", "104", "1", "2", "97", "1", "0", "", "", "", "0", "", "", "", "", "2", "7.032", "0.078", "0.0015", "0.93299", "13.056", "0.102", "0.0023", "0.81383", "-0.00001", "1", "1", "", "8325", "", "", "", "", "", "", "", "", "88.8", "99.6", "", "", "", "", "97.5"]} +{"pcdb_id": 17512, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "32CDi Compact ErP LPG", "winter_efficiency_pct": 89.8, "summer_efficiency_pct": 88.8, "comparative_hot_water_efficiency_pct": 73.7, "output_kw_max": 24.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0007, "loss_factor_f1_kwh_per_day": 1.18698, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017512", "000035", "0", "2020/Jul/17 12:04", "Bosch Thermotechnology", "Worcester", "Greenstar", "32CDi Compact ErP LPG", "47-406-80", "2015", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "89.8", "88.8", "", "73.7", "", "2", "0", "", "104", "1", "2", "97", "1", "0", "", "", "", "0", "", "", "", "", "1", "7.3", "0.089", "0.0007", "1.18698", "", "", "", "", "", "1", "1", "", "8325", "", "", "", "", "", "", "", "", "90.4", "98.2", "", "", "", "", "96.7"]} +{"pcdb_id": 17513, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "32CDi Compact ErP", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 87.2, "comparative_hot_water_efficiency_pct": 75.0, "output_kw_max": 24.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.0027, "loss_factor_f1_kwh_per_day": 0.91849, "loss_factor_f2_kwh_per_day": 0.80367, "rejected_factor_f3_per_litre": 2e-05, "raw": ["017513", "000035", "0", "2020/Jul/27 16:09", "Bosch Thermotechnology", "Worcester", "Greenstar", "32CDi Compact ErP", "47-406-79", "2015", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "89.2", "87.2", "", "75.0", "", "2", "", "", "104", "1", "2", "97", "1", "0", "", "", "", "0", "", "", "", "", "2", "7.024", "0.08", "0.0027", "0.91849", "13.021", "0.103", "0.001", "0.80367", "0.00002", "1", "1", "", "8325", "", "", "", "", "", "", "", "", "88.8", "99.6", "", "", "", "", "97.5"]} +{"pcdb_id": 17514, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "36CDi Compact ErP LPG", "winter_efficiency_pct": 89.8, "summer_efficiency_pct": 88.8, "comparative_hot_water_efficiency_pct": 73.4, "output_kw_max": 24.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.002, "loss_factor_f1_kwh_per_day": 1.208, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017514", "000035", "0", "2020/Jul/17 12:20", "Bosch Thermotechnology", "Worcester", "Greenstar", "36CDi Compact ErP LPG", "47-406-82", "2015", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "89.8", "88.8", "", "73.4", "", "2", "0", "", "104", "1", "2", "97", "1", "0", "", "", "", "0", "", "", "", "", "1", "7.33", "0.088", "0.002", "1.208", "", "", "", "", "", "1", "1", "", "8325", "", "", "", "", "", "", "", "", "90.4", "98.2", "", "", "", "", "96.7"]} +{"pcdb_id": 17515, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "36CDi Compact ErP", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 87.9, "comparative_hot_water_efficiency_pct": 74.7, "output_kw_max": 24.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.0017, "loss_factor_f1_kwh_per_day": 0.94834, "loss_factor_f2_kwh_per_day": 0.88074, "rejected_factor_f3_per_litre": 1e-05, "raw": ["017515", "000035", "0", "2020/Jul/27 16:20", "Bosch Thermotechnology", "Worcester", "Greenstar", "36CDi Compact ErP", "47-406-81", "2015", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "89.2", "87.9", "", "74.7", "", "2", "", "", "104", "1", "2", "97", "1", "0", "", "", "", "0", "", "", "", "", "2", "7.049", "0.086", "0.0017", "0.94834", "13.009", "0.105", "0.001", "0.88074", "0.00001", "1", "1", "", "8325", "", "", "", "", "", "", "", "", "88.8", "99.6", "", "", "", "", "97.5"]} +{"pcdb_id": 17516, "brand_name": "Worcester", "model_name": "Greenstar Heatslave II External", "model_qualifier": "12/18 ErP", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 82.2, "comparative_hot_water_efficiency_pct": 44.8, "output_kw_max": 18.0, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 1, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017516", "000035", "0", "2024/Jan/31 10:17", "Bosch Thermotechnology", "Worcester", "Greenstar Heatslave II External", "12/18 ErP", "", "2015", "2018", "4", "1", "2", "2", "0", "", "", "2", "2", "1", "12", "18", "", "", "88.3", "82.2", "", "44.8", "", "2", "", "", "203", "1", "1", "194", "1.7", "1", "1", "", "42", "0", "25", "1", "84", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0123", "", "", "", "", "", "", "", "", "91.1", "95.4", "", "", "", "", "94.6"]} +{"pcdb_id": 17517, "brand_name": "Worcester", "model_name": "Greenstar Heatslave II External", "model_qualifier": "18/25 ErP", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 82.0, "comparative_hot_water_efficiency_pct": 44.7, "output_kw_max": 25.0, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 1, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017517", "000035", "0", "2024/Jan/31 10:17", "Bosch Thermotechnology", "Worcester", "Greenstar Heatslave II External", "18/25 ErP", "", "2015", "2018", "4", "1", "2", "2", "0", "", "", "2", "2", "1", "18", "25", "", "", "88.1", "82.0", "", "44.7", "", "2", "", "", "203", "1", "1", "194", "1.7", "1", "1", "", "42", "0", "25", "1", "86", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0123", "", "", "", "", "", "", "", "", "90.9", "95.1", "", "", "", "", "94.3"]} +{"pcdb_id": 17518, "brand_name": "Worcester", "model_name": "Greenstar Heatslave II External", "model_qualifier": "25/32 ErP", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 81.8, "comparative_hot_water_efficiency_pct": 44.6, "output_kw_max": 32.0, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 1, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017518", "000035", "0", "2024/Jan/31 10:17", "Bosch Thermotechnology", "Worcester", "Greenstar Heatslave II External", "25/32 ErP", "", "2015", "2018", "4", "1", "2", "2", "0", "", "", "2", "2", "1", "25", "32", "", "", "87.9", "81.8", "", "44.6", "", "2", "", "", "203", "1", "1", "233", "1.7", "1", "1", "", "42", "0", "25", "1", "88", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0123", "", "", "", "", "", "", "", "", "91.4", "94.3", "", "", "", "", "93.7"]} +{"pcdb_id": 17519, "brand_name": "Worcester", "model_name": "Greenstar Heatslave II", "model_qualifier": "12/18 ErP", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 82.2, "comparative_hot_water_efficiency_pct": 44.8, "output_kw_max": 18.0, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 1, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017519", "000035", "0", "2024/Jan/31 10:17", "Bosch Thermotechnology", "Worcester", "Greenstar Heatslave II", "12/18 ErP", "", "2015", "2018", "4", "1", "1", "2", "0", "", "", "2", "3", "1", "12", "18", "", "", "88.3", "82.2", "", "44.8", "", "2", "", "", "203", "1", "1", "194", "1.7", "1", "1", "", "42", "0", "25", "1", "84", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0123", "", "", "", "", "", "", "", "", "91.1", "95.4", "", "", "", "", "94.6"]} +{"pcdb_id": 17520, "brand_name": "Worcester", "model_name": "Greenstar Heatslave II", "model_qualifier": "18/25 ErP", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 82.0, "comparative_hot_water_efficiency_pct": 44.7, "output_kw_max": 25.0, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 1, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017520", "000035", "0", "2024/Jan/31 10:17", "Bosch Thermotechnology", "Worcester", "Greenstar Heatslave II", "18/25 ErP", "", "2015", "2018", "4", "1", "1", "2", "0", "", "", "2", "3", "1", "18", "25", "", "", "88.1", "82.0", "", "44.7", "", "2", "", "", "203", "1", "1", "209", "1.7", "1", "1", "", "42", "0", "25", "1", "86", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0123", "", "", "", "", "", "", "", "", "90.9", "95.1", "", "", "", "", "94.3"]} +{"pcdb_id": 17521, "brand_name": "Worcester", "model_name": "Greenstar Heatslave II", "model_qualifier": "25/32 ErP", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 81.8, "comparative_hot_water_efficiency_pct": 44.6, "output_kw_max": 32.0, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 1, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017521", "000035", "0", "2024/Jan/31 10:17", "Bosch Thermotechnology", "Worcester", "Greenstar Heatslave II", "25/32 ErP", "", "2015", "2018", "4", "1", "1", "2", "0", "", "", "2", "3", "1", "25", "32", "", "", "87.9", "81.8", "", "44.6", "", "2", "", "", "203", "1", "1", "233", "1.7", "1", "1", "", "42", "0", "25", "1", "88", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0123", "", "", "", "", "", "", "", "", "91.4", "94.3", "", "", "", "", "93.7"]} +{"pcdb_id": 17522, "brand_name": "Worcester", "model_name": "Greenstar Danesmoor", "model_qualifier": "12/18 ErP", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 58.8, "output_kw_max": 18.0, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017522", "000035", "0", "2020/Sep/08 10:45", "Bosch Thermotechnology", "Worcester", "Greenstar Danesmoor", "12/18 ErP", "", "2015", "2018", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "12", "18", "", "", "88.3", "80.5", "", "58.8", "", "2", "", "", "201", "1", "1", "143", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.1", "95.4", "", "", "", "", "94.6"]} +{"pcdb_id": 17524, "brand_name": "Worcester", "model_name": "Greenstar Danesmoor", "model_qualifier": "18/25 ErP", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 58.7, "output_kw_max": 25.0, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017524", "000035", "0", "2020/Sep/08 10:46", "Bosch Thermotechnology", "Worcester", "Greenstar Danesmoor", "18/25 ErP", "", "2015", "2018", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "18", "25", "", "", "88.1", "80.3", "", "58.7", "", "2", "", "", "201", "1", "1", "160", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.9", "95.1", "", "", "", "", "94.3"]} +{"pcdb_id": 17525, "brand_name": "Worcester", "model_name": "Greenstar Danesmoor", "model_qualifier": "25/32 ErP", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 32.0, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017525", "000035", "0", "2020/Sep/08 10:46", "Bosch Thermotechnology", "Worcester", "Greenstar Danesmoor", "25/32 ErP", "", "2015", "2018", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "25", "32", "", "", "87.9", "80.1", "", "58.5", "", "2", "", "", "201", "1", "1", "160", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.4", "94.3", "", "", "", "", "93.7"]} +{"pcdb_id": 17526, "brand_name": "Worcester", "model_name": "Greenstar Danesmoor External", "model_qualifier": "12/18 ErP", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 58.8, "output_kw_max": 18.0, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017526", "000035", "0", "2020/Sep/08 10:46", "Bosch Thermotechnology", "Worcester", "Greenstar Danesmoor External", "12/18 ErP", "", "2015", "2018", "4", "1", "2", "1", "0", "", "", "2", "2", "1", "12", "18", "", "", "88.3", "80.5", "", "58.8", "", "2", "", "", "201", "1", "1", "143", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.1", "95.4", "", "", "", "", "94.6"]} +{"pcdb_id": 17527, "brand_name": "Worcester", "model_name": "Greenstar Danesmoor External", "model_qualifier": "18/25 ErP", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 58.7, "output_kw_max": 25.0, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017527", "000035", "0", "2020/Sep/08 10:46", "Bosch Thermotechnology", "Worcester", "Greenstar Danesmoor External", "18/25 ErP", "", "2015", "2018", "4", "1", "2", "1", "0", "", "", "2", "2", "1", "18", "25", "", "", "88.1", "80.3", "", "58.7", "", "2", "", "", "201", "1", "1", "160", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.9", "95.1", "", "", "", "", "94.3"]} +{"pcdb_id": 17528, "brand_name": "Worcester", "model_name": "Greenstar Danesmoor External", "model_qualifier": "25/32 ErP", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 32.0, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017528", "000035", "0", "2020/Sep/08 10:46", "Bosch Thermotechnology", "Worcester", "Greenstar Danesmoor External", "25/32 ErP", "", "2015", "2018", "4", "1", "2", "1", "0", "", "", "2", "2", "1", "25", "32", "", "", "87.9", "80.1", "", "58.5", "", "2", "", "", "201", "1", "1", "160", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.4", "94.3", "", "", "", "", "93.7"]} +{"pcdb_id": 17529, "brand_name": "Worcester", "model_name": "Greenstar Danesmoor Utility", "model_qualifier": "12/18 ErP", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 58.8, "output_kw_max": 18.0, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017529", "000035", "0", "2020/Sep/08 10:46", "Bosch Thermotechnology", "Worcester", "Greenstar Danesmoor Utility", "12/18 ErP", "", "2015", "2018", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "12", "18", "", "", "88.3", "80.5", "", "58.8", "", "2", "", "", "201", "1", "1", "143", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.1", "95.4", "", "", "", "", "94.6"]} +{"pcdb_id": 17530, "brand_name": "Worcester", "model_name": "Greenstar Danesmoor Utility", "model_qualifier": "18/25 ErP", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 58.7, "output_kw_max": 25.0, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017530", "000035", "0", "2020/Sep/08 10:47", "Bosch Thermotechnology", "Worcester", "Greenstar Danesmoor Utility", "18/25 ErP", "", "2015", "2018", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "18", "25", "", "", "88.1", "80.3", "", "58.7", "", "2", "", "", "201", "1", "1", "160", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.9", "95.1", "", "", "", "", "94.3"]} +{"pcdb_id": 17531, "brand_name": "Worcester", "model_name": "Greenstar Danesmoor Utility", "model_qualifier": "25/32 ErP", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 32.0, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017531", "000035", "0", "2020/Sep/08 10:47", "Bosch Thermotechnology", "Worcester", "Greenstar Danesmoor Utility", "25/32 ErP", "", "2015", "2018", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "25", "32", "", "", "87.9", "80.1", "", "58.5", "", "2", "", "", "201", "1", "1", "160", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.4", "94.3", "", "", "", "", "93.7"]} +{"pcdb_id": 17532, "brand_name": "Worcester", "model_name": "Greenstar Danesmoor System", "model_qualifier": "12/18 ErP", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 58.8, "output_kw_max": 18.0, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017532", "000035", "0", "2020/Sep/08 10:47", "Bosch Thermotechnology", "Worcester", "Greenstar Danesmoor System", "12/18 ErP", "", "2015", "2018", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "12", "18", "", "", "88.3", "80.5", "", "58.8", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.1", "95.4", "", "", "", "", "94.6"]} +{"pcdb_id": 17533, "brand_name": "Worcester", "model_name": "Greenstar Danesmoor System", "model_qualifier": "18/25 ErP", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 58.7, "output_kw_max": 25.0, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017533", "000035", "0", "2020/Sep/08 10:47", "Bosch Thermotechnology", "Worcester", "Greenstar Danesmoor System", "18/25 ErP", "", "2015", "2018", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "18", "25", "", "", "88.1", "80.3", "", "58.7", "", "2", "", "", "201", "1", "1", "208", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.9", "95.1", "", "", "", "", "94.3"]} +{"pcdb_id": 17534, "brand_name": "Worcester", "model_name": "Greenstar Danesmoor System", "model_qualifier": "25/32 ErP", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 32.0, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017534", "000035", "0", "2020/Sep/08 10:47", "Bosch Thermotechnology", "Worcester", "Greenstar Danesmoor System", "25/32 ErP", "", "2015", "2018", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "25", "32", "", "", "87.9", "80.1", "", "58.5", "", "2", "", "", "201", "1", "1", "208", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.4", "94.3", "", "", "", "", "93.7"]} +{"pcdb_id": 17535, "brand_name": "Worcester", "model_name": "Greenstar Danesmoor System External", "model_qualifier": "12/18 ErP", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 58.8, "output_kw_max": 18.0, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017535", "000035", "0", "2020/Sep/08 10:47", "Bosch Thermotechnology", "Worcester", "Greenstar Danesmoor System External", "12/18 ErP", "", "2015", "2018", "4", "1", "2", "1", "0", "", "", "2", "2", "1", "12", "18", "", "", "88.3", "80.5", "", "58.8", "", "2", "", "", "201", "1", "1", "191", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.1", "95.4", "", "", "", "", "94.6"]} +{"pcdb_id": 17536, "brand_name": "Worcester", "model_name": "Greenstar Danesmoor System External", "model_qualifier": "18/25 ErP", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 58.7, "output_kw_max": 25.0, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017536", "000035", "0", "2020/Sep/08 10:47", "Bosch Thermotechnology", "Worcester", "Greenstar Danesmoor System External", "18/25 ErP", "", "2015", "2018", "4", "1", "2", "1", "0", "", "", "2", "2", "1", "18", "25", "", "", "88.1", "80.3", "", "58.7", "", "2", "", "", "201", "1", "1", "208", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.9", "95.1", "", "", "", "", "94.3"]} +{"pcdb_id": 17537, "brand_name": "Worcester", "model_name": "Greenstar Danesmoor System External", "model_qualifier": "25/32 ErP", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 32.0, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017537", "000035", "0", "2020/Sep/08 10:47", "Bosch Thermotechnology", "Worcester", "Greenstar Danesmoor System External", "25/32 ErP", "", "2015", "2018", "4", "1", "2", "1", "0", "", "", "2", "2", "1", "25", "32", "", "", "87.9", "80.1", "", "58.5", "", "2", "", "", "201", "1", "1", "208", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.4", "94.3", "", "", "", "", "93.7"]} +{"pcdb_id": 17538, "brand_name": "Worcester", "model_name": "Greenstar Danesmoor System Utility", "model_qualifier": "12/18 ErP", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 58.8, "output_kw_max": 18.0, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017538", "000035", "0", "2020/Sep/08 10:47", "Bosch Thermotechnology", "Worcester", "Greenstar Danesmoor System Utility", "12/18 ErP", "", "2015", "2018", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "12", "18", "", "", "88.3", "80.5", "", "58.8", "", "2", "", "", "201", "1", "1", "191", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.1", "95.4", "", "", "", "", "94.6"]} +{"pcdb_id": 17539, "brand_name": "Worcester", "model_name": "Greenstar Danesmoor System Utility", "model_qualifier": "18/25 ErP", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 58.7, "output_kw_max": 25.0, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017539", "000035", "0", "2020/Sep/08 10:47", "Bosch Thermotechnology", "Worcester", "Greenstar Danesmoor System Utility", "18/25 ErP", "", "2015", "2018", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "18", "25", "", "", "88.1", "80.3", "", "58.7", "", "2", "", "", "201", "1", "1", "208", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.9", "95.1", "", "", "", "", "94.3"]} +{"pcdb_id": 17540, "brand_name": "Worcester", "model_name": "Greenstar Danesmoor System Utility", "model_qualifier": "25/32 ErP", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 32.0, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017540", "000035", "0", "2020/Sep/08 10:48", "Bosch Thermotechnology", "Worcester", "Greenstar Danesmoor System Utility", "25/32 ErP", "", "2015", "2018", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "25", "32", "", "", "87.9", "80.1", "", "58.5", "", "2", "", "", "201", "1", "1", "208", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.4", "94.3", "", "", "", "", "93.7"]} +{"pcdb_id": 17541, "brand_name": "Worcester", "model_name": "Greenstar Danesmoor Utility", "model_qualifier": "32/50 ErP", "winter_efficiency_pct": 87.7, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 50.0, "final_year_of_manufacture": 2019, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017541", "000035", "0", "2020/Sep/08 10:48", "Bosch Thermotechnology", "Worcester", "Greenstar Danesmoor Utility", "32/50 ErP", "", "2015", "2019", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "32", "50", "", "", "87.7", "79.9", "", "58.4", "", "2", "", "", "201", "1", "1", "188", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.0", "94.0", "", "", "", "", "93.4"]} +{"pcdb_id": 17542, "brand_name": "Worcester", "model_name": "Greenstar Danesmoor Utility", "model_qualifier": "50/70 ErP", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 70.0, "final_year_of_manufacture": 2019, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017542", "000035", "0", "2020/Sep/08 10:48", "Bosch Thermotechnology", "Worcester", "Greenstar Danesmoor Utility", "50/70 ErP", "", "2015", "2019", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "50", "70", "", "", "87.9", "80.1", "", "58.5", "", "2", "", "", "201", "1", "1", "176", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.6", "94.3", "", "", "", "", "93.8"]} +{"pcdb_id": 17543, "brand_name": "Ravenheat", "model_name": "HE 80(T)", "model_qualifier": "Natural Gas", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 86.6, "comparative_hot_water_efficiency_pct": 76.8, "output_kw_max": 19.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0104, "loss_factor_f1_kwh_per_day": 0.68941, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017543", "000026", "0", "2015/May/06 11:53", "Ravenheat Manufacturing", "Ravenheat", "HE 80(T)", "Natural Gas", "", "2015", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "19.5", "19.5", "", "", "88.0", "86.6", "", "76.8", "", "2", "", "", "104", "1", "2", "110", "3", "0", "", "", "", "0", "", "", "", "", "1", "6.859", "0.134", "0.0104", "0.68941", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "96.9", "", "", "", "", "95.2"]} +{"pcdb_id": 17544, "brand_name": "Ravenheat", "model_name": "HE 90(T)", "model_qualifier": "Natural gas", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 86.6, "comparative_hot_water_efficiency_pct": 69.1, "output_kw_max": 23.9, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0065, "loss_factor_f1_kwh_per_day": 1.44231, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017544", "000026", "0", "2015/May/06 11:53", "Ravenheat Manufacturing", "Ravenheat", "HE 90(T)", "Natural gas", "", "2015", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "23.9", "23.9", "", "", "88.1", "86.6", "", "69.1", "", "2", "", "", "104", "1", "2", "160", "3", "0", "", "", "", "0", "", "", "", "", "1", "7.618", "0.129", "0.0065", "1.44231", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "97.1", "", "", "", "", "95.4"]} +{"pcdb_id": 17545, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "12Ri ErP LPG", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 12.0, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017545", "000035", "0", "2020/Sep/08 10:48", "Bosch Thermotechnology", "Worcester", "Greenstar", "12Ri ErP LPG", "41-406-42", "2015", "2018", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "12", "12", "", "", "88.3", "79.3", "", "57.9", "", "2", "0", "0", "102", "1", "2", "36", "6.2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.5", "94.8", "", "", "", "", "93.8"]} +{"pcdb_id": 17546, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "12Ri ErP", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 12.0, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017546", "000035", "0", "2020/Sep/08 10:48", "Bosch Thermotechnology", "Worcester", "Greenstar", "12Ri ErP", "41-406-41", "2015", "2018", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "12", "12", "", "", "88.1", "79.1", "", "57.7", "", "2", "", "", "102", "1", "2", "37", "6.2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "97.0", "", "", "", "", "95.3"]} +{"pcdb_id": 17547, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "15Ri ErP LPG", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 15.0, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017547", "000035", "0", "2020/Sep/08 10:48", "Bosch Thermotechnology", "Worcester", "Greenstar", "15Ri ErP LPG", "41-406-44", "2015", "2018", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "15", "15", "", "", "88.4", "79.4", "", "58.0", "", "2", "0", "0", "102", "1", "2", "48", "6.2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.0", "95.0", "", "", "", "", "94.0"]} +{"pcdb_id": 17548, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "15Ri ErP", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 15.0, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017548", "000035", "0", "2020/Sep/08 10:48", "Bosch Thermotechnology", "Worcester", "Greenstar", "15Ri ErP", "41-406-43", "2015", "2018", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "15", "15", "", "", "88.1", "79.1", "", "57.7", "", "2", "", "", "102", "1", "2", "50", "6.2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "97.0", "", "", "", "", "95.3"]} +{"pcdb_id": 17549, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "18Ri ErP LPG", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 18.0, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017549", "000035", "0", "2020/Sep/08 10:48", "Bosch Thermotechnology", "Worcester", "Greenstar", "18Ri ErP LPG", "41-406-46", "2015", "2018", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "18.0", "18.0", "", "", "88.5", "79.5", "", "58.1", "", "2", "0", "0", "102", "1", "2", "52", "6.2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.7", "95.1", "", "", "", "", "94.1"]} +{"pcdb_id": 17550, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "18Ri ErP", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 18.0, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017550", "000035", "0", "2020/Sep/08 10:49", "Bosch Thermotechnology", "Worcester", "Greenstar", "18Ri ErP", "41-406-45", "2015", "2018", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18", "18", "", "", "88.1", "79.1", "", "57.7", "", "2", "", "", "102", "1", "2", "53", "6.2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "97.0", "", "", "", "", "95.3"]} +{"pcdb_id": 17551, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "24Ri ErP LPG", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 24.0, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017551", "000035", "0", "2020/Sep/08 10:49", "Bosch Thermotechnology", "Worcester", "Greenstar", "24Ri ErP LPG", "41-406-48", "2015", "2018", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "24", "24", "", "", "88.2", "79.2", "", "57.8", "", "2", "0", "0", "102", "1", "2", "58", "6.2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.7", "94.3", "", "", "", "", "93.4"]} +{"pcdb_id": 17553, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "24Ri ErP", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 24.0, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017553", "000035", "0", "2020/Sep/08 10:49", "Bosch Thermotechnology", "Worcester", "Greenstar", "24Ri ErP", "41-406-47", "2015", "2018", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24", "24", "", "", "88.5", "79.5", "", "58.0", "", "2", "", "", "102", "1", "2", "54", "6.2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "97.9", "", "", "", "", "96.1"]} +{"pcdb_id": 17554, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "29CDi Classic ErP LPG", "winter_efficiency_pct": 89.5, "summer_efficiency_pct": 80.9, "comparative_hot_water_efficiency_pct": 56.9, "output_kw_max": 30.0, "final_year_of_manufacture": 2019, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017554", "000035", "0", "2020/Jul/22 15:05", "Bosch Thermotechnology", "Worcester", "Greenstar", "29CDi Classic ErP LPG", "47-406-66", "2015", "2019", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "30.0", "30.0", "", "", "89.5", "80.9", "", "56.9", "", "2", "1", "", "104", "1", "2", "58", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "8305", "", "", "", "", "", "", "", "", "90.0", "100.2", "", "", "", "", "98.3"]} +{"pcdb_id": 17556, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "29CDi Classic ErP", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 86.7, "comparative_hot_water_efficiency_pct": 71.2, "output_kw_max": 30.0, "final_year_of_manufacture": 2019, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0061, "loss_factor_f1_kwh_per_day": 1.23987, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017556", "000035", "0", "2020/Jul/22 15:07", "Bosch Thermotechnology", "Worcester", "Greenstar", "29CDi Classic ErP", "47-406-65", "2015", "2019", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "30.0", "30.0", "", "", "88.5", "86.7", "", "71.2", "", "2", "", "", "104", "1", "2", "58", "2", "0", "", "", "", "0", "", "", "", "", "1", "7.4", "0.122", "0.0061", "1.23987", "", "", "", "", "", "", "", "", "8305", "", "", "", "", "", "", "", "", "88.0", "98.0", "", "", "", "", "96.1"]} +{"pcdb_id": 17557, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "34CDi Classic ErP LPG", "winter_efficiency_pct": 89.5, "summer_efficiency_pct": 80.9, "comparative_hot_water_efficiency_pct": 56.9, "output_kw_max": 30.0, "final_year_of_manufacture": 2019, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017557", "000035", "0", "2020/Jul/22 15:10", "Bosch Thermotechnology", "Worcester", "Greenstar", "34CDi Classic ErP LPG", "47-406-68", "2015", "2019", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "30.0", "30.0", "", "", "89.5", "80.9", "", "56.9", "", "2", "1", "", "104", "1", "2", "58", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "8305", "", "", "", "", "", "", "", "", "90.0", "100.2", "", "", "", "", "98.3"]} +{"pcdb_id": 17558, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "34CDi Classic ErP", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 86.7, "comparative_hot_water_efficiency_pct": 72.3, "output_kw_max": 30.0, "final_year_of_manufacture": 2019, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0039, "loss_factor_f1_kwh_per_day": 1.13727, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017558", "000035", "0", "2020/Jul/22 15:15", "Bosch Thermotechnology", "Worcester", "Greenstar", "34CDi Classic ErP", "47-406-67", "2015", "2019", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "30.0", "30.0", "", "", "88.5", "86.7", "", "72.3", "", "2", "", "", "104", "1", "2", "58", "2", "0", "", "", "", "0", "", "", "", "", "1", "7.28", "0.123", "0.0039", "1.13727", "", "", "", "", "", "", "", "", "8305", "", "", "", "", "", "", "", "", "88.0", "98.0", "", "", "", "", "96.1"]} +{"pcdb_id": 17559, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "38CDi Classic ErP LPG", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 56.8, "output_kw_max": 30.0, "final_year_of_manufacture": 2019, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017559", "000035", "0", "2020/Sep/08 13:44", "Bosch Thermotechnology", "Worcester", "Greenstar", "38CDi Classic ErP LPG", "47-406-70", "2015", "2019", "2", "2", "1", "2", "0", "", "", "2", "2", "1", "30.0", "30.0", "", "", "89.4", "80.8", "", "56.8", "", "2", "1", "", "104", "1", "2", "52", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "8305", "", "", "", "", "", "", "", "", "90.1", "99.9", "", "", "", "", "98.1"]} +{"pcdb_id": 17560, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "38CDi Classic ErP", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 86.7, "comparative_hot_water_efficiency_pct": 71.5, "output_kw_max": 30.0, "final_year_of_manufacture": 2019, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0039, "loss_factor_f1_kwh_per_day": 1.22598, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017560", "000035", "0", "2020/Sep/08 13:45", "Bosch Thermotechnology", "Worcester", "Greenstar", "38CDi Classic ErP", "47-406-69", "2015", "2019", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "30.0", "30.0", "", "", "88.4", "86.7", "", "71.5", "", "2", "", "", "104", "1", "2", "52", "2", "0", "", "", "", "0", "", "", "", "", "1", "7.37", "0.129", "0.0039", "1.22598", "", "", "", "", "", "", "", "", "8305", "", "", "", "", "", "", "", "", "88.1", "97.8", "", "", "", "", "95.9"]} +{"pcdb_id": 17561, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "42CDi Classic ErP LPG", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 56.8, "output_kw_max": 30.0, "final_year_of_manufacture": 2019, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017561", "000035", "0", "2020/Sep/08 13:45", "Bosch Thermotechnology", "Worcester", "Greenstar", "42CDi Classic ErP LPG", "47-406-72", "2015", "2019", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "30.0", "30.0", "", "", "89.4", "80.8", "", "56.8", "", "2", "1", "", "104", "1", "2", "51", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "8305", "", "", "", "", "", "", "", "", "90.1", "99.9", "", "", "", "", "98.1"]} +{"pcdb_id": 17562, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "42CDi Classic ErP", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 86.7, "comparative_hot_water_efficiency_pct": 72.0, "output_kw_max": 30.0, "final_year_of_manufacture": 2019, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0049, "loss_factor_f1_kwh_per_day": 1.16268, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017562", "000035", "0", "2020/Sep/08 13:45", "Bosch Thermotechnology", "Worcester", "Greenstar", "42CDi Classic ErP", "47-406-71", "2015", "2019", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "30.0", "30.0", "", "", "88.4", "86.7", "", "72.0", "", "2", "", "", "104", "1", "2", "51", "2", "0", "", "", "", "0", "", "", "", "", "1", "7.31", "0.128", "0.0049", "1.16268", "", "", "", "", "", "", "", "", "8305", "", "", "", "", "", "", "", "", "88.1", "97.8", "", "", "", "", "95.9"]} +{"pcdb_id": 17563, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "30CDi Classic Regular ErP LPG", "winter_efficiency_pct": 89.5, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 58.8, "output_kw_max": 30.0, "final_year_of_manufacture": 2019, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017563", "000035", "0", "2020/Sep/08 13:45", "Bosch Thermotechnology", "Worcester", "Greenstar", "30CDi Classic Regular ErP LPG", "41-406-34", "2015", "2019", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "30.0", "30.0", "", "", "89.5", "80.5", "", "58.8", "", "2", "1", "", "102", "1", "2", "58", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.0", "100.2", "", "", "", "", "98.3"]} +{"pcdb_id": 17564, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "30CDi Classic Regular ErP", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 30.0, "final_year_of_manufacture": 2019, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017564", "000035", "0", "2020/Sep/08 13:46", "Bosch Thermotechnology", "Worcester", "Greenstar", "30CDi Classic Regular ErP", "41-406-33", "2015", "2019", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "30.0", "30.0", "", "", "88.5", "79.5", "", "58.1", "", "2", "", "", "102", "1", "2", "58", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "98.0", "", "", "", "", "96.1"]} +{"pcdb_id": 17565, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "40CDi Classic Regular ErP LPG", "winter_efficiency_pct": 89.5, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 58.8, "output_kw_max": 40.8, "final_year_of_manufacture": 2019, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017565", "000035", "0", "2020/Sep/08 13:46", "Bosch Thermotechnology", "Worcester", "Greenstar", "40CDi Classic Regular ErP LPG", "41-406-36", "2015", "2019", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "40.8", "40.8", "", "", "89.5", "80.5", "", "58.8", "", "2", "1", "", "102", "1", "2", "90", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.8", "100.3", "", "", "", "", "98.3"]} +{"pcdb_id": 17566, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "40CDi Classic Regular ErP", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 40.8, "final_year_of_manufacture": 2019, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017566", "000035", "0", "2020/Sep/08 13:46", "Bosch Thermotechnology", "Worcester", "Greenstar", "40CDi Classic Regular ErP", "41-406-35", "2015", "2019", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "40.8", "40.8", "", "", "88.5", "79.5", "", "58.1", "", "2", "", "", "102", "1", "2", "90", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "98.1", "", "", "", "", "96.2"]} +{"pcdb_id": 17567, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "30CDi Classic System ErP LPG", "winter_efficiency_pct": 89.5, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 58.8, "output_kw_max": 30.0, "final_year_of_manufacture": 2019, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017567", "000035", "0", "2020/Sep/08 13:46", "Bosch Thermotechnology", "Worcester", "Greenstar", "30CDi Classic System ErP LPG", "41-406-38", "2015", "2019", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "30.0", "30.0", "", "", "89.5", "80.5", "", "58.8", "", "2", "1", "", "102", "1", "2", "58", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "8305", "", "", "", "", "", "", "", "", "90.0", "100.2", "", "", "", "", "98.3"]} +{"pcdb_id": 17568, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "30CDi Classic System ErP", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 30.0, "final_year_of_manufacture": 2019, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017568", "000035", "0", "2020/Sep/08 13:46", "Bosch Thermotechnology", "Worcester", "Greenstar", "30CDi Classic System ErP", "41-406-37", "2015", "2019", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "30.0", "30.0", "", "", "88.5", "79.5", "", "58.1", "", "2", "", "", "102", "1", "2", "58", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "8305", "", "", "", "", "", "", "", "", "88.0", "98.0", "", "", "", "", "96.1"]} +{"pcdb_id": 17569, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "35CDi Classic System ErP LPG", "winter_efficiency_pct": 89.5, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 58.8, "output_kw_max": 34.0, "final_year_of_manufacture": 2019, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017569", "000035", "0", "2020/Sep/08 13:46", "Bosch Thermotechnology", "Worcester", "Greenstar", "35CDi Classic System ErP LPG", "41-406-40", "2015", "2019", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "34.0", "34.0", "", "", "89.5", "80.5", "", "58.8", "", "2", "1", "", "102", "1", "2", "60", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "8305", "", "", "", "", "", "", "", "", "89.8", "100.3", "", "", "", "", "98.3"]} +{"pcdb_id": 17570, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "35CDi Classic System ErP", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 34.0, "final_year_of_manufacture": 2019, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017570", "000035", "0", "2020/Sep/08 13:46", "Bosch Thermotechnology", "Worcester", "Greenstar", "35CDi Classic System ErP", "41-406-39", "2015", "2019", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "34.0", "34.0", "", "", "88.5", "79.5", "", "58.1", "", "2", "", "", "102", "1", "2", "60", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "8305", "", "", "", "", "", "", "", "", "87.8", "98.1", "", "", "", "", "96.2"]} +{"pcdb_id": 17572, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "FS 30CDi Regular ErP", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 30.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017572", "000035", "0", "2015/Apr/27 15:10", "Bosch Thermotechnology", "Worcester", "Greenstar", "FS 30CDi Regular ErP", "41-406-03", "2008", "current", "1", "1", "1", "1", "0", "", "", "2", "2", "2", "30", "30", "", "", "88.2", "79.2", "", "57.9", "", "2", "", "", "102", "1", "2", "60", "9", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.6", "97.1", "", "", "", "", "95.5"]} +{"pcdb_id": 17574, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "FS 42CDi Regular ErP", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 40.8, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017574", "000035", "0", "2015/Apr/27 15:09", "Bosch Thermotechnology", "Worcester", "Greenstar", "FS 42CDi Regular ErP", "41-406-04", "2008", "current", "1", "1", "1", "1", "0", "", "", "2", "2", "2", "40.8", "40.8", "", "", "88.1", "79.1", "", "57.8", "", "2", "", "", "102", "1", "2", "80", "9", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.1", "97.0", "", "", "", "", "95.3"]} +{"pcdb_id": 17576, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "Highflow 440CDi ErP", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 80.9, "comparative_hot_water_efficiency_pct": 43.8, "output_kw_max": 29.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 1, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017576", "000035", "0", "2024/Jan/31 10:17", "Bosch Thermotechnology", "Worcester", "Greenstar", "Highflow 440CDi ErP", "47-406-85", "2008", "current", "1", "1", "1", "2", "0", "", "", "2", "2", "2", "29.2", "29.2", "", "", "88.2", "80.9", "", "43.8", "", "2", "", "", "106", "1", "2", "164", "10", "1", "1", "", "47", "0", "25", "3", "65", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "8305", "", "", "", "", "", "", "", "", "88.6", "97.1", "", "", "", "", "95.5"]} +{"pcdb_id": 17578, "brand_name": "Worcester", "model_name": "Greenstar", "model_qualifier": "Highflow 550CDi ErP", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 80.9, "comparative_hot_water_efficiency_pct": 43.8, "output_kw_max": 30.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 1, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017578", "000035", "0", "2024/Jan/31 10:17", "Bosch Thermotechnology", "Worcester", "Greenstar", "Highflow 550CDi ErP", "47-406-87", "2008", "current", "1", "1", "1", "2", "0", "", "", "2", "2", "2", "30.6", "30.6", "", "", "88.2", "80.9", "", "43.8", "", "2", "", "", "106", "1", "2", "164", "10", "1", "1", "", "47", "0", "25", "3", "65", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "8305", "", "", "", "", "", "", "", "", "88.6", "97.1", "", "", "", "", "95.5"]} +{"pcdb_id": 17580, "brand_name": "ATAG", "model_name": "iR15", "model_qualifier": "", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 13.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017580", "000299", "0", "2015/Jun/08 16:04", "ATAG Verwarming Nederland BV", "ATAG", "iR15", "", "41-310-32", "2015", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "13.3", "13.3", "", "", "89.1", "80.1", "", "58.5", "", "2", "", "", "102", "1", "2", "23", "4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.8", "99.2", "", "", "", "", "97.2"]} +{"pcdb_id": 17581, "brand_name": "ATAG", "model_name": "iS32", "model_qualifier": "", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 18.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017581", "000299", "0", "2015/Jun/08 16:05", "ATAG Verwarming Nederland BV", "ATAG", "iS32", "", "41-310-26", "2015", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "18", "18", "", "", "89.1", "80.1", "", "58.5", "", "2", "", "", "102", "1", "2", "74", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.6", "99.5", "", "", "", "", "97.4"]} +{"pcdb_id": 17582, "brand_name": "ATAG", "model_name": "iS15", "model_qualifier": "", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 13.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017582", "000299", "0", "2015/Jun/08 16:10", "ATAG Verwarming Nederland BV", "ATAG", "iS15", "", "41-310-20", "2015", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "13.3", "13.3", "", "", "89.1", "80.1", "", "58.5", "", "2", "", "", "102", "1", "2", "68", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.8", "99.2", "", "", "", "", "97.2"]} +{"pcdb_id": 17583, "brand_name": "ATAG", "model_name": "iS24", "model_qualifier": "", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 21.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017583", "000299", "0", "2015/Jun/08 16:10", "ATAG Verwarming Nederland BV", "ATAG", "iS24", "", "41-310-24", "2015", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "21.2", "21.2", "", "", "89.1", "80.1", "", "58.5", "", "2", "", "", "102", "1", "2", "96", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "99.4", "", "", "", "", "97.3"]} +{"pcdb_id": 17585, "brand_name": "ATAG", "model_name": "iR32", "model_qualifier": "", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 28.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017585", "000299", "0", "2015/Jun/08 16:11", "ATAG Verwarming Nederland BV", "ATAG", "iR32", "", "41-310-38", "2015", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "28.4", "28.4", "", "", "89.1", "80.1", "", "58.5", "", "2", "", "", "102", "1", "2", "40", "4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.6", "99.5", "", "", "", "", "97.4"]} +{"pcdb_id": 17586, "brand_name": "ATAG", "model_name": "iR24", "model_qualifier": "", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 21.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017586", "000299", "0", "2015/Jun/08 16:12", "ATAG Verwarming Nederland BV", "ATAG", "iR24", "", "41-310-36", "2015", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "21.2", "21.2", "", "", "89.1", "80.1", "", "58.5", "", "2", "", "", "102", "1", "2", "36", "4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "99.4", "", "", "", "", "97.3"]} +{"pcdb_id": 17587, "brand_name": "ATAG", "model_name": "iC40", "model_qualifier": "", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 88.2, "comparative_hot_water_efficiency_pct": 76.5, "output_kw_max": 28.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.0008, "loss_factor_f1_kwh_per_day": 0.78828, "loss_factor_f2_kwh_per_day": 0.75508, "rejected_factor_f3_per_litre": 0.0, "raw": ["017587", "000299", "0", "2020/Apr/09 16:13", "ATAG Verwarming Nederland BV", "ATAG", "iC40", "", "47-310-25", "2015", "current", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "28.3", "28.3", "", "", "89.1", "88.2", "", "76.5", "", "2", "", "", "104", "1", "2", "74", "5", "0", "", "", "", "0", "", "", "", "", "2", "6.885", "0.179", "0.0008", "0.78828", "12.646", "0.196", "0.0004", "0.75508", "0.0", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.6", "99.5", "", "", "", "", "97.4"]} +{"pcdb_id": 17588, "brand_name": "ATAG", "model_name": "iR18", "model_qualifier": "", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 15.9, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017588", "000299", "0", "2015/Jun/08 16:19", "ATAG Verwarming Nederland BV", "ATAG", "iR18", "", "41-310-34", "2015", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "15.9", "15.9", "", "", "89.1", "80.1", "", "58.5", "", "2", "", "", "102", "1", "2", "28", "4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.6", "99.4", "", "", "", "", "97.3"]} +{"pcdb_id": 17589, "brand_name": "ATAG", "model_name": "iC36", "model_qualifier": "", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 86.9, "comparative_hot_water_efficiency_pct": 76.6, "output_kw_max": 28.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0008, "loss_factor_f1_kwh_per_day": 0.77574, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017589", "000299", "0", "2020/Jan/22 13:14", "ATAG Verwarming Nederland BV", "ATAG", "iC36", "", "47-310-23", "2015", "current", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "28.3", "28.3", "", "", "89.1", "86.9", "", "76.6", "", "2", "", "", "104", "1", "2", "74", "5", "0", "", "", "", "0", "", "", "", "", "1", "6.872", "0.182", "0.0008", "0.77574", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.6", "99.5", "", "", "", "", "97.4"]} +{"pcdb_id": 17590, "brand_name": "ATAG", "model_name": "iC28", "model_qualifier": "", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 88.2, "comparative_hot_water_efficiency_pct": 77.4, "output_kw_max": 21.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.0008, "loss_factor_f1_kwh_per_day": 0.70169, "loss_factor_f2_kwh_per_day": 0.67557, "rejected_factor_f3_per_litre": 0.0, "raw": ["017590", "000299", "0", "2020/Apr/09 16:13", "ATAG Verwarming Nederland BV", "ATAG", "iC28", "", "47-310-21", "2015", "current", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "21.2", "21.2", "", "", "89.1", "88.2", "", "77.4", "", "2", "", "", "104", "1", "2", "74", "5", "0", "", "", "", "0", "", "", "", "", "2", "6.802", "0.169", "0.0008", "0.70169", "12.464", "0.178", "0.0004", "0.67557", "0.0", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "99.4", "", "", "", "", "97.3"]} +{"pcdb_id": 17591, "brand_name": "ATAG", "model_name": "iC24", "model_qualifier": "", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 88.2, "comparative_hot_water_efficiency_pct": 77.4, "output_kw_max": 21.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.0008, "loss_factor_f1_kwh_per_day": 0.70552, "loss_factor_f2_kwh_per_day": 0.67938, "rejected_factor_f3_per_litre": 0.0, "raw": ["017591", "000299", "0", "2020/Apr/09 16:12", "ATAG Verwarming Nederland BV", "ATAG", "iC24", "", "47-310-19", "2015", "current", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "21.2", "21.2", "", "", "89.1", "88.2", "", "77.4", "", "2", "", "", "104", "1", "2", "74", "5", "0", "", "", "", "0", "", "", "", "", "2", "6.806", "0.168", "0.0008", "0.70552", "12.475", "0.188", "0.0004", "0.67938", "0.0", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "99.4", "", "", "", "", "97.3"]} +{"pcdb_id": 17592, "brand_name": "ATAG", "model_name": "iS40", "model_qualifier": "", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 35.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017592", "000299", "0", "2015/Jun/08 16:21", "ATAG Verwarming Nederland BV", "ATAG", "iS40", "", "41-310-28", "2015", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "35.4", "35.4", "", "", "89.1", "80.1", "", "58.5", "", "2", "", "", "102", "1", "2", "99", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.4", "99.4", "", "", "", "", "97.3"]} +{"pcdb_id": 17593, "brand_name": "ATAG", "model_name": "iR40", "model_qualifier": "", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 35.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017593", "000299", "0", "2015/Jun/08 16:22", "ATAG Verwarming Nederland BV", "ATAG", "iR40", "", "41-310-40", "2015", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "35.4", "35.4", "", "", "89.1", "80.1", "", "58.5", "", "2", "", "", "102", "1", "2", "46", "4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.4", "99.4", "", "", "", "", "97.3"]} +{"pcdb_id": 17594, "brand_name": "ATAG", "model_name": "iS18", "model_qualifier": "", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 15.9, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017594", "000299", "0", "2015/Jun/08 16:22", "ATAG Verwarming Nederland BV", "ATAG", "iS18", "", "41-310-22", "2015", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "15.9", "15.9", "", "", "89.1", "80.1", "", "58.5", "", "2", "", "", "102", "1", "2", "77", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.6", "99.4", "", "", "", "", "97.3"]} +{"pcdb_id": 17595, "brand_name": "Alpha", "model_name": "InTec2 35CE", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 86.7, "comparative_hot_water_efficiency_pct": 72.1, "output_kw_max": 28.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0112, "loss_factor_f1_kwh_per_day": 1.11644, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017595", "000001", "0", "2016/Sep/20 00:00", "Alpha Therm", "Alpha", "InTec2 35CE", "", "", "2015", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28", "28", "", "", "88.3", "86.7", "", "72.1", "", "2", "", "", "104", "1", "2", "105", "6", "0", "", "", "", "0", "", "", "", "", "1", "7.303", "0.104", "0.0112", "1.11644", "", "", "", "", "", "", "", "", "1005", "", "", "", "", "", "", "", "", "88.0", "97.6", "", "", "", "", "95.8"]} +{"pcdb_id": 17596, "brand_name": "Alpha", "model_name": "InTec2 30CE", "model_qualifier": "", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 86.6, "comparative_hot_water_efficiency_pct": 75.0, "output_kw_max": 24.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0045, "loss_factor_f1_kwh_per_day": 0.87804, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017596", "000001", "0", "2016/Sep/20 00:00", "Alpha Therm", "Alpha", "InTec2 30CE", "", "", "2015", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "88.2", "86.6", "", "75.0", "", "2", "", "", "104", "1", "2", "95", "6", "0", "", "", "", "0", "", "", "", "", "1", "7.019", "0.125", "0.0045", "0.87804", "", "", "", "", "", "", "", "", "1005", "", "", "", "", "", "", "", "", "87.8", "97.4", "", "", "", "", "95.6"]} +{"pcdb_id": 17597, "brand_name": "Alpha", "model_name": "InTec2 30SE", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 28.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017597", "000001", "0", "2016/Sep/20 00:00", "Alpha Therm", "Alpha", "InTec2 30SE", "", "", "2015", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "28", "28", "", "", "88.3", "79.3", "", "57.9", "", "2", "", "", "102", "1", "2", "105", "6", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "1005", "", "", "", "", "", "", "", "", "88.0", "97.6", "", "", "", "", "95.8"]} +{"pcdb_id": 17598, "brand_name": "Alpha", "model_name": "InTec2 26CE", "model_qualifier": "", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 86.6, "comparative_hot_water_efficiency_pct": 73.7, "output_kw_max": 20.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0122, "loss_factor_f1_kwh_per_day": 0.95089, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017598", "000001", "0", "2016/Sep/20 00:00", "Alpha Therm", "Alpha", "InTec2 26CE", "", "", "2015", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "20", "20", "", "", "88.2", "86.6", "", "73.7", "", "2", "", "", "104", "1", "2", "90", "6", "0", "", "", "", "0", "", "", "", "", "1", "7.144", "0.117", "0.0122", "0.95089", "", "", "", "", "", "", "", "", "1005", "", "", "", "", "", "", "", "", "87.8", "97.4", "", "", "", "", "95.6"]} +{"pcdb_id": 17599, "brand_name": "Alpha", "model_name": "InTec2 20SE", "model_qualifier": "", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 18.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017599", "000001", "0", "2016/Sep/20 00:00", "Alpha Therm", "Alpha", "InTec2 20SE", "", "", "2015", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18", "18", "", "", "88.2", "79.2", "", "57.9", "", "2", "", "", "102", "1", "2", "85", "6", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "1005", "", "", "", "", "", "", "", "", "87.8", "97.4", "", "", "", "", "95.6"]} +{"pcdb_id": 17600, "brand_name": "Alpha", "model_name": "InTec2 20SE", "model_qualifier": "", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 18.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017600", "000001", "0", "2016/Sep/20 00:00", "Alpha Therm", "Alpha", "InTec2 20SE", "", "", "2015", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "18", "18", "", "", "89.2", "80.2", "", "58.6", "", "2", "1", "", "102", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "1005", "", "", "", "", "", "", "", "", "89.7", "99.6", "", "", "", "", "97.7"]} +{"pcdb_id": 17601, "brand_name": "Alpha", "model_name": "InTec2 26CE", "model_qualifier": "", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 88.5, "comparative_hot_water_efficiency_pct": 74.9, "output_kw_max": 20.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0079, "loss_factor_f1_kwh_per_day": 1.0182, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017601", "000001", "0", "2016/Sep/20 00:00", "Alpha Therm", "Alpha", "InTec2 26CE", "", "", "2015", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "20", "20", "", "", "89.2", "88.5", "", "74.9", "", "2", "1", "", "104", "1", "2", "90", "6", "0", "", "", "", "0", "", "", "", "", "1", "7.188", "0.126", "0.0079", "1.0182", "", "", "", "", "", "", "", "", "1005", "", "", "", "", "", "", "", "", "89.7", "99.6", "", "", "", "", "97.7"]} +{"pcdb_id": 17602, "brand_name": "Alpha", "model_name": "InTec2 30CE", "model_qualifier": "", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 88.6, "comparative_hot_water_efficiency_pct": 74.5, "output_kw_max": 24.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0086, "loss_factor_f1_kwh_per_day": 1.05571, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017602", "000001", "0", "2016/Sep/20 00:00", "Alpha Therm", "Alpha", "InTec2 30CE", "", "", "2015", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "89.2", "88.6", "", "74.5", "", "2", "1", "", "104", "1", "2", "105", "6", "0", "", "", "", "0", "", "", "", "", "1", "7.229", "0.122", "0.0086", "1.05571", "", "", "", "", "", "", "", "", "1005", "", "", "", "", "", "", "", "", "89.8", "99.6", "", "", "", "", "97.7"]} +{"pcdb_id": 17603, "brand_name": "Alpha", "model_name": "InTec2 30SE", "model_qualifier": "", "winter_efficiency_pct": 89.3, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 58.7, "output_kw_max": 28.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017603", "000001", "0", "2016/Sep/20 00:00", "Alpha Therm", "Alpha", "InTec2 30SE", "", "", "2015", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "28", "28", "", "", "89.3", "80.3", "", "58.7", "", "2", "1", "", "102", "1", "2", "105", "6", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "1005", "", "", "", "", "", "", "", "", "90.0", "99.7", "", "", "", "", "97.9"]} +{"pcdb_id": 17604, "brand_name": "Alpha", "model_name": "InTec2 35CE", "model_qualifier": "", "winter_efficiency_pct": 89.3, "summer_efficiency_pct": 88.6, "comparative_hot_water_efficiency_pct": 72.6, "output_kw_max": 28.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0085, "loss_factor_f1_kwh_per_day": 1.24124, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017604", "000001", "0", "2016/Sep/20 00:00", "Alpha Therm", "Alpha", "InTec2 35CE", "", "", "2015", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "28", "28", "", "", "89.3", "88.6", "", "72.6", "", "2", "1", "", "104", "1", "2", "", "", "0", "", "", "", "0", "", "", "", "", "1", "7.416", "0.104", "0.0085", "1.24124", "", "", "", "", "", "", "", "", "1005", "", "", "", "", "", "", "", "", "90.0", "99.7", "", "", "", "", "97.9"]} +{"pcdb_id": 17606, "brand_name": "Alpha", "model_name": "Eco2 Plus", "model_qualifier": "", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 86.6, "comparative_hot_water_efficiency_pct": 72.8, "output_kw_max": 24.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0159, "loss_factor_f1_kwh_per_day": 1.01136, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017606", "000001", "0", "2016/Sep/20 00:00", "Alpha Therm", "Alpha", "Eco2 Plus", "", "", "2015", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.0", "24.0", "", "", "88.2", "86.6", "", "72.8", "", "2", "", "", "104", "1", "2", "95", "4.5", "0", "", "", "", "0", "", "", "", "", "1", "7.23", "0.121", "0.0159", "1.01136", "", "", "", "", "", "", "", "", "1005", "", "", "", "", "", "", "", "", "87.8", "97.4", "", "", "", "", "95.6"]} +{"pcdb_id": 17609, "brand_name": "Alpha", "model_name": "Eco2 Plus", "model_qualifier": "", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 88.5, "comparative_hot_water_efficiency_pct": 73.2, "output_kw_max": 24.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0081, "loss_factor_f1_kwh_per_day": 1.17575, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017609", "000001", "0", "2016/Sep/20 00:00", "Alpha Therm", "Alpha", "Eco2 Plus", "", "", "2015", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24.0", "24.0", "", "", "89.2", "88.5", "", "73.2", "", "2", "1", "", "104", "1", "2", "95", "4.5", "0", "", "", "", "0", "", "", "", "", "1", "7.353", "0.123", "0.0081", "1.17575", "", "", "", "", "", "", "", "", "1005", "", "", "", "", "", "", "", "", "89.7", "99.6", "", "", "", "", "97.7"]} +{"pcdb_id": 17610, "brand_name": "Alpha", "model_name": "InTec2 25XE", "model_qualifier": "", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 86.6, "comparative_hot_water_efficiency_pct": 73.1, "output_kw_max": 20.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0171, "loss_factor_f1_kwh_per_day": 0.98444, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017610", "000001", "0", "2016/Sep/20 00:00", "Alpha Therm", "Alpha", "InTec2 25XE", "", "", "2015", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "20.0", "20.0", "", "", "88.2", "86.6", "", "73.1", "", "2", "", "", "104", "1", "2", "90", "4.5", "0", "", "", "", "0", "", "", "", "", "1", "7.209", "0.126", "0.0171", "0.98444", "", "", "", "", "", "", "", "", "1005", "", "", "", "", "", "", "", "", "87.8", "97.3", "", "", "", "", "95.5"]} +{"pcdb_id": 17611, "brand_name": "Alpha", "model_name": "InTec2 25XE", "model_qualifier": "", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 88.5, "comparative_hot_water_efficiency_pct": 75.2, "output_kw_max": 20.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0088, "loss_factor_f1_kwh_per_day": 0.98297, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017611", "000001", "0", "2016/Sep/20 00:00", "Alpha Therm", "Alpha", "InTec2 25XE", "", "", "2015", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "20.0", "20.0", "", "", "89.2", "88.5", "", "75.2", "", "2", "1", "", "104", "1", "2", "90", "4.5", "0", "", "", "", "0", "", "", "", "", "1", "7.157", "0.119", "0.0088", "0.98297", "", "", "", "", "", "", "", "", "1005", "", "", "", "", "", "", "", "", "89.7", "99.5", "", "", "", "", "97.6"]} +{"pcdb_id": 17612, "brand_name": "Alpha", "model_name": "InTec2 28XE", "model_qualifier": "", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 86.6, "comparative_hot_water_efficiency_pct": 72.8, "output_kw_max": 24.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.016, "loss_factor_f1_kwh_per_day": 1.0123, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017612", "000001", "0", "2016/Sep/20 00:00", "Alpha Therm", "Alpha", "InTec2 28XE", "", "", "2015", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.0", "24.0", "", "", "88.2", "86.6", "", "72.8", "", "2", "", "", "104", "1", "2", "95", "4.5", "0", "", "", "", "0", "", "", "", "", "1", "7.231", "0.121", "0.016", "1.0123", "", "", "", "", "", "", "", "", "1005", "", "", "", "", "", "", "", "", "87.8", "97.4", "", "", "", "", "95.6"]} +{"pcdb_id": 17613, "brand_name": "Alpha", "model_name": "InTec2 28XE", "model_qualifier": "", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 88.5, "comparative_hot_water_efficiency_pct": 73.2, "output_kw_max": 24.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0081, "loss_factor_f1_kwh_per_day": 1.17575, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017613", "000001", "0", "2016/Sep/20 00:00", "Alpha Therm", "Alpha", "InTec2 28XE", "", "", "2015", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24.0", "24.0", "", "", "89.2", "88.5", "", "73.2", "", "2", "1", "", "104", "1", "2", "95", "4.5", "0", "", "", "", "0", "", "", "", "", "1", "7.353", "0.123", "0.0081", "1.17575", "", "", "", "", "", "", "", "", "1005", "", "", "", "", "", "", "", "", "89.7", "99.6", "", "", "", "", "97.7"]} +{"pcdb_id": 17614, "brand_name": "Potterton", "model_name": "Promax Ultra", "model_qualifier": "Combi 24 ErP", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 86.7, "comparative_hot_water_efficiency_pct": 77.6, "output_kw_max": 20.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0043, "loss_factor_f1_kwh_per_day": 0.65911, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017614", "000005", "0", "2015/Sep/21 14:23", "Baxi Heating UK", "Potterton", "Promax Ultra", "Combi 24 ErP", "GC No. 47-393-54", "2015", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "20", "20", "", "", "88.5", "86.7", "", "77.6", "", "2", "", "", "104", "1", "2", "85", "3.5", "0", "", "", "", "0", "", "", "", "", "1", "6.786", "0.098", "0.0043", "0.65911", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "88.0", "98.0", "", "", "", "", "96.1"]} +{"pcdb_id": 17615, "brand_name": "Potterton", "model_name": "Promax Ultra", "model_qualifier": "Combi 28 ErP", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 86.7, "comparative_hot_water_efficiency_pct": 77.3, "output_kw_max": 24.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0044, "loss_factor_f1_kwh_per_day": 0.68225, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017615", "000005", "0", "2016/Jul/13 14:38", "Baxi Heating UK", "Potterton", "Promax Ultra", "Combi 28 ErP", "GC No. 47-393-55", "2015", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "88.5", "86.7", "", "77.3", "", "2", "", "", "104", "1", "2", "90", "3.5", "0", "", "", "", "0", "", "", "", "", "1", "6.813", "0.098", "0.0044", "0.68225", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "87.9", "98.0", "", "", "", "", "96.1"]} +{"pcdb_id": 17616, "brand_name": "Potterton", "model_name": "Promax Ultra", "model_qualifier": "Combi 33 ErP", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 86.7, "comparative_hot_water_efficiency_pct": 77.3, "output_kw_max": 28.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0045, "loss_factor_f1_kwh_per_day": 0.68548, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017616", "000005", "0", "2015/Sep/21 14:23", "Baxi Heating UK", "Potterton", "Promax Ultra", "Combi 33 ErP", "GC No. 47-393-56", "2015", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28", "28", "", "", "88.5", "86.7", "", "77.3", "", "2", "", "", "104", "1", "2", "95", "3.5", "0", "", "", "", "0", "", "", "", "", "1", "6.812", "0.086", "0.0045", "0.68548", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "88.1", "98.1", "", "", "", "", "96.2"]} +{"pcdb_id": 17617, "brand_name": "Potterton", "model_name": "Promax Ultra", "model_qualifier": "Combi 40 ErP", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 86.7, "comparative_hot_water_efficiency_pct": 77.6, "output_kw_max": 32.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0043, "loss_factor_f1_kwh_per_day": 0.65689, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017617", "000005", "0", "2015/Sep/21 14:23", "Baxi Heating UK", "Potterton", "Promax Ultra", "Combi 40 ErP", "GC No. 47-393-57", "2015", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "32", "32", "", "", "88.5", "86.7", "", "77.6", "", "2", "", "", "104", "1", "2", "100", "3.5", "0", "", "", "", "0", "", "", "", "", "1", "6.786", "0.098", "0.0043", "0.65689", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "87.9", "98.0", "", "", "", "", "96.1"]} +{"pcdb_id": 17619, "brand_name": "Grant", "model_name": "Vortex Eco", "model_qualifier": "Utility System 15-21", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 21.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017619", "000048", "0", "2015/Jul/16 14:45", "Grant Engineering (UK)", "Grant", "Vortex Eco", "Utility System 15-21", "", "2015", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "15.5", "21.5", "", "", "88.0", "80.2", "", "58.6", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.5", "94.4", "", "", "", "", "93.9"]} +{"pcdb_id": 17623, "brand_name": "Grant", "model_name": "Vortex Eco", "model_qualifier": "Utility System 21-26", "winter_efficiency_pct": 87.8, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 26.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017623", "000048", "0", "2015/Jul/16 14:46", "Grant Engineering (UK)", "Grant", "Vortex Eco", "Utility System 21-26", "", "2015", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "21.5", "26.3", "", "", "87.8", "80.0", "", "58.4", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.4", "94.4", "", "", "", "", "93.6"]} +{"pcdb_id": 17624, "brand_name": "Grant", "model_name": "Vortex Eco", "model_qualifier": "Utility System 26-35", "winter_efficiency_pct": 87.5, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 35.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017624", "000048", "0", "2015/Jul/16 14:47", "Grant Engineering (UK)", "Grant", "Vortex Eco", "Utility System 26-35", "", "2015", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "26.3", "35.3", "", "", "87.5", "79.7", "", "58.2", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.3", "93.8", "", "", "", "", "93.1"]} +{"pcdb_id": 17625, "brand_name": "Grant", "model_name": "Vortex Eco", "model_qualifier": "External System 15-21", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 21.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017625", "000048", "0", "2015/Jul/16 14:48", "Grant Engineering (UK)", "Grant", "Vortex Eco", "External System 15-21", "", "2015", "current", "4", "1", "2", "1", "0", "", "", "2", "3", "2", "15.5", "21.5", "", "", "88.0", "80.2", "", "58.6", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.5", "94.4", "", "", "", "", "93.9"]} +{"pcdb_id": 17626, "brand_name": "Grant", "model_name": "Vortex Eco", "model_qualifier": "External System 21-26", "winter_efficiency_pct": 87.8, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 26.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017626", "000048", "0", "2015/Jul/16 14:49", "Grant Engineering (UK)", "Grant", "Vortex Eco", "External System 21-26", "", "2015", "current", "4", "1", "2", "1", "0", "", "", "2", "3", "1", "21.5", "26.3", "", "", "87.8", "80.0", "", "58.4", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.4", "94.4", "", "", "", "", "93.6"]} +{"pcdb_id": 17627, "brand_name": "Grant", "model_name": "Vortex Eco", "model_qualifier": "External System 26-35", "winter_efficiency_pct": 87.5, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 35.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017627", "000048", "0", "2015/Jul/16 14:49", "Grant Engineering (UK)", "Grant", "Vortex Eco", "External System 26-35", "", "2015", "current", "4", "1", "2", "1", "0", "", "", "2", "3", "2", "26.3", "35.3", "", "", "87.5", "79.7", "", "58.2", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.3", "93.8", "", "", "", "", "93.1"]} +{"pcdb_id": 17628, "brand_name": "Baxi", "model_name": "Ecoblue Advance 24 Combi ErPD", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 86.7, "comparative_hot_water_efficiency_pct": 77.6, "output_kw_max": 20.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0043, "loss_factor_f1_kwh_per_day": 0.65911, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017628", "000005", "0", "2015/Sep/21 14:23", "Baxi Heating UK", "Baxi", "Ecoblue Advance 24 Combi ErPD", "", "GC No. 47-077-14", "2015", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "20", "20", "", "", "88.5", "86.7", "", "77.6", "", "2", "", "", "104", "1", "2", "85", "3.5", "0", "", "", "", "0", "", "", "", "", "1", "6.786", "0.098", "0.0043", "0.65911", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "88.0", "98.0", "", "", "", "", "96.1"]} +{"pcdb_id": 17629, "brand_name": "Baxi", "model_name": "Ecoblue Advance 28 Combi ErPD", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 86.7, "comparative_hot_water_efficiency_pct": 77.3, "output_kw_max": 24.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0044, "loss_factor_f1_kwh_per_day": 0.68225, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017629", "000005", "0", "2015/Sep/21 14:23", "Baxi Heating UK", "Baxi", "Ecoblue Advance 28 Combi ErPD", "", "GC No. 47-077-15", "2015", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "88.5", "86.7", "", "77.3", "", "2", "", "", "104", "1", "2", "90", "3.5", "0", "", "", "", "0", "", "", "", "", "1", "6.813", "0.098", "0.0044", "0.68225", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "87.9", "98.0", "", "", "", "", "96.1"]} +{"pcdb_id": 17630, "brand_name": "Baxi", "model_name": "Ecoblue Advance 33 Combi ErPD", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 86.7, "comparative_hot_water_efficiency_pct": 77.2, "output_kw_max": 28.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0045, "loss_factor_f1_kwh_per_day": 0.69191, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017630", "000005", "0", "2015/Sep/21 14:23", "Baxi Heating UK", "Baxi", "Ecoblue Advance 33 Combi ErPD", "", "GC No. 47-077-16", "2015", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28", "28", "", "", "88.5", "86.7", "", "77.2", "", "2", "", "", "104", "1", "2", "95", "3.5", "0", "", "", "", "0", "", "", "", "", "1", "6.821", "0.086", "0.0045", "0.69191", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "88.0", "98.1", "", "", "", "", "96.2"]} +{"pcdb_id": 17631, "brand_name": "Baxi", "model_name": "Ecoblue Advance 40 Combi ErPD", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 86.7, "comparative_hot_water_efficiency_pct": 77.6, "output_kw_max": 32.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0043, "loss_factor_f1_kwh_per_day": 0.65689, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017631", "000005", "0", "2015/Sep/21 14:23", "Baxi Heating UK", "Baxi", "Ecoblue Advance 40 Combi ErPD", "", "GC No. 47-077-17", "2015", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "32", "32", "", "", "88.5", "86.7", "", "77.6", "", "2", "", "", "104", "1", "2", "100", "3.5", "0", "", "", "", "0", "", "", "", "", "1", "6.786", "0.098", "0.0043", "0.65689", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "87.9", "98.0", "", "", "", "", "96.1"]} +{"pcdb_id": 17632, "brand_name": "Baxi", "model_name": "Ecoblue 24 Combi ErP", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 86.7, "comparative_hot_water_efficiency_pct": 77.6, "output_kw_max": 20.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0043, "loss_factor_f1_kwh_per_day": 0.65911, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017632", "000005", "0", "2015/Sep/21 14:23", "Baxi Heating UK", "Baxi", "Ecoblue 24 Combi ErP", "", "GC No. 47-077-11", "2015", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "20", "20", "", "", "88.5", "86.7", "", "77.6", "", "2", "", "", "104", "1", "2", "85", "3.5", "0", "", "", "", "0", "", "", "", "", "1", "6.786", "0.098", "0.0043", "0.65911", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "88.0", "98.0", "", "", "", "", "96.1"]} +{"pcdb_id": 17633, "brand_name": "Baxi", "model_name": "Ecoblue 28 Combi ErP", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 86.7, "comparative_hot_water_efficiency_pct": 77.3, "output_kw_max": 24.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0044, "loss_factor_f1_kwh_per_day": 0.68225, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017633", "000005", "0", "2015/Sep/21 14:23", "Baxi Heating UK", "Baxi", "Ecoblue 28 Combi ErP", "", "GC No. 47-077-12", "2015", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "88.5", "86.7", "", "77.3", "", "2", "", "", "104", "1", "2", "90", "3.5", "0", "", "", "", "0", "", "", "", "", "1", "6.813", "0.098", "0.0044", "0.68225", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "87.9", "98.0", "", "", "", "", "96.1"]} +{"pcdb_id": 17634, "brand_name": "Baxi", "model_name": "Ecoblue33 Combi ErP", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 86.7, "comparative_hot_water_efficiency_pct": 77.2, "output_kw_max": 28.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0045, "loss_factor_f1_kwh_per_day": 0.69191, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017634", "000005", "0", "2015/Sep/21 14:23", "Baxi Heating UK", "Baxi", "Ecoblue33 Combi ErP", "", "GC No. 47-077-13", "2014", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28", "28", "", "", "88.5", "86.7", "", "77.2", "", "2", "", "", "104", "1", "2", "95", "3.5", "0", "", "", "", "0", "", "", "", "", "1", "6.821", "0.086", "0.0045", "0.69191", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "88.0", "98.1", "", "", "", "", "96.2"]} +{"pcdb_id": 17635, "brand_name": "Baxi", "model_name": "Ecoblue + 24 Combi ErP", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 86.7, "comparative_hot_water_efficiency_pct": 77.6, "output_kw_max": 20.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0043, "loss_factor_f1_kwh_per_day": 0.65911, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017635", "000005", "0", "2015/Sep/21 14:23", "Baxi Heating UK", "Baxi", "Ecoblue + 24 Combi ErP", "", "GC No. 47-077-08", "2015", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "20", "20", "", "", "88.5", "86.7", "", "77.6", "", "2", "", "", "104", "1", "2", "85", "3.5", "0", "", "", "", "0", "", "", "", "", "1", "6.786", "0.098", "0.0043", "0.65911", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "88.0", "98.0", "", "", "", "", "96.1"]} +{"pcdb_id": 17636, "brand_name": "Baxi", "model_name": "Ecoblue + 28 Combi ErP", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 86.7, "comparative_hot_water_efficiency_pct": 77.3, "output_kw_max": 24.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0044, "loss_factor_f1_kwh_per_day": 0.68225, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017636", "000005", "0", "2015/Sep/21 14:23", "Baxi Heating UK", "Baxi", "Ecoblue + 28 Combi ErP", "", "GC No. 47-077-09", "2015", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "88.5", "86.7", "", "77.3", "", "2", "", "", "104", "1", "2", "90", "3.5", "0", "", "", "", "0", "", "", "", "", "1", "6.813", "0.098", "0.0044", "0.68225", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "87.9", "98.0", "", "", "", "", "96.1"]} +{"pcdb_id": 17637, "brand_name": "Baxi", "model_name": "Ecoblue + 33 Combi ErP", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 86.7, "comparative_hot_water_efficiency_pct": 77.2, "output_kw_max": 28.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0045, "loss_factor_f1_kwh_per_day": 0.69191, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017637", "000005", "0", "2015/Sep/21 14:23", "Baxi Heating UK", "Baxi", "Ecoblue + 33 Combi ErP", "", "GC No. 47-077-10", "2015", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28", "28", "", "", "88.5", "86.7", "", "77.2", "", "2", "", "", "104", "1", "2", "95", "3.5", "0", "", "", "", "0", "", "", "", "", "1", "6.821", "0.086", "0.0045", "0.69191", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "88.0", "98.1", "", "", "", "", "96.2"]} +{"pcdb_id": 17638, "brand_name": "Baxi", "model_name": "Ecoblue 12 System ErP", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 12.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017638", "000005", "0", "2015/Sep/21 14:23", "Baxi Heating UK", "Baxi", "Ecoblue 12 System ErP", "", "GC No. 41-470-23", "2015", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "12", "12", "", "", "88.6", "79.6", "", "58.1", "", "2", "", "", "102", "1", "2", "75", "3.5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "88.1", "98.2", "", "", "", "", "96.3"]} +{"pcdb_id": 17639, "brand_name": "Baxi", "model_name": "Ecoblue 15 System ErP", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 15.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017639", "000005", "0", "2015/Sep/21 14:23", "Baxi Heating UK", "Baxi", "Ecoblue 15 System ErP", "", "GC No. 41-470-24", "2015", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "15", "15", "", "", "88.5", "79.5", "", "58.1", "", "2", "", "", "102", "1", "2", "80", "3.5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "88.0", "98.1", "", "", "", "", "96.2"]} +{"pcdb_id": 17640, "brand_name": "Baxi", "model_name": "Ecoblue18 System ErP", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 18.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017640", "000005", "0", "2015/Sep/21 14:23", "Baxi Heating UK", "Baxi", "Ecoblue18 System ErP", "", "GC No. 41-470-25", "2015", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18", "18", "", "", "88.5", "79.5", "", "58.1", "", "2", "", "", "102", "1", "2", "80", "3.5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "88.0", "98.1", "", "", "", "", "96.2"]} +{"pcdb_id": 17641, "brand_name": "Baxi", "model_name": "Ecoblue 24 System ErP", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 24.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017641", "000005", "0", "2015/Sep/21 14:23", "Baxi Heating UK", "Baxi", "Ecoblue 24 System ErP", "", "GC No. 41-470-26", "2015", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24", "24", "", "", "88.5", "79.5", "", "58.1", "", "2", "", "", "102", "1", "2", "85", "3.5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "87.9", "98.0", "", "", "", "", "96.1"]} +{"pcdb_id": 17642, "brand_name": "Baxi", "model_name": "Ecoblue 28 System ErP", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 28.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017642", "000005", "0", "2015/Sep/21 14:23", "Baxi Heating UK", "Baxi", "Ecoblue 28 System ErP", "", "GC No. 41-470-27", "2015", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "28", "28", "", "", "88.5", "79.5", "", "58.1", "", "2", "", "", "102", "1", "2", "90", "3.5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "87.9", "98.0", "", "", "", "", "96.1"]} +{"pcdb_id": 17643, "brand_name": "Baxi", "model_name": "Ecoblue 32 System ErP", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 32.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017643", "000005", "0", "2015/Sep/21 14:23", "Baxi Heating UK", "Baxi", "Ecoblue 32 System ErP", "", "GC No. 41-470-28", "2015", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "32", "32", "", "", "88.5", "79.5", "", "58.1", "", "2", "", "", "102", "1", "2", "90", "3.5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "87.9", "98.0", "", "", "", "", "96.1"]} +{"pcdb_id": 17644, "brand_name": "Vaillant", "model_name": "ecoTEC plus 825 H combi A", "model_qualifier": "VUW GB 256/5-5", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 87.0, "comparative_hot_water_efficiency_pct": 76.1, "output_kw_max": 19.3, "final_year_of_manufacture": 2017, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.003, "loss_factor_f1_kwh_per_day": 0.81911, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017644", "000031", "0", "2019/Mar/04 11:01", "Vaillant Group UK", "Vaillant", "ecoTEC plus 825 H combi A", "VUW GB 256/5-5", "47-044-57", "2015", "2017", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "19.3", "19.3", "", "", "88.5", "87.0", "", "76.1", "", "2", "", "", "104", "1", "2", "31", "2", "0", "", "", "", "0", "", "", "", "", "1", "6.923", "0.12", "0.003", "0.81911", "", "", "", "", "", "1", "1", "", "0045", "", "", "", "", "", "", "", "", "88.8", "97.8", "", "", "", "", "96.1"]} +{"pcdb_id": 17645, "brand_name": "Vaillant", "model_name": "ecoTEC pro 24 H combi A", "model_qualifier": "VUW 246/5-3 A", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 87.0, "comparative_hot_water_efficiency_pct": 76.3, "output_kw_max": 18.9, "final_year_of_manufacture": 2017, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.003, "loss_factor_f1_kwh_per_day": 0.80529, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017645", "000031", "0", "2019/Mar/04 11:05", "Vaillant Group UK", "Vaillant", "ecoTEC pro 24 H combi A", "VUW 246/5-3 A", "47-044-54", "2015", "2017", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "18.9", "18.9", "", "", "88.5", "87.0", "", "76.3", "", "2", "", "", "104", "1", "2", "32", "2", "0", "", "", "", "0", "", "", "", "", "1", "6.904", "0.129", "0.003", "0.80529", "", "", "", "", "", "1", "1", "", "0045", "", "", "", "", "", "", "", "", "89.0", "97.8", "", "", "", "", "96.1"]} +{"pcdb_id": 17646, "brand_name": "Vokera", "model_name": "Vision", "model_qualifier": "25S", "winter_efficiency_pct": 89.7, "summer_efficiency_pct": 80.7, "comparative_hot_water_efficiency_pct": 58.9, "output_kw_max": 23.74, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017646", "000011", "0", "2015/Jul/15 16:41", "Vokera", "Vokera", "Vision", "25S", "41 094 86", "2014", "current", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "23.74", "23.74", "", "", "89.7", "80.7", "", "58.9", "", "2", "0", "", "102", "1", "2", "77", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.1", "98.0", "", "", "", "", "96.5"]} +{"pcdb_id": 17647, "brand_name": "Baxi", "model_name": "Megaflo 15 System ErP", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 15.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017647", "000005", "0", "2015/Jul/16 11:26", "Baxi Heating UK", "Baxi", "Megaflo 15 System ErP", "", "GC No. 41-470-18", "2015", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "15", "15", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "95", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "87.9", "96.8", "", "", "", "", "95.1"]} +{"pcdb_id": 17648, "brand_name": "Baxi", "model_name": "Megaflo 18 System ErP", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 18.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017648", "000005", "0", "2015/Jul/16 11:27", "Baxi Heating UK", "Baxi", "Megaflo 18 System ErP", "", "GC No. 41-470-19", "2015", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18", "18", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "105", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "87.9", "96.9", "", "", "", "", "95.2"]} +{"pcdb_id": 17649, "brand_name": "Baxi", "model_name": "Megaflo 24 System ErP", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 24.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017649", "000005", "0", "2015/Jul/16 11:27", "Baxi Heating UK", "Baxi", "Megaflo 24 System ErP", "", "GC No. 41-470-20", "2015", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24", "24", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "115", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "87.9", "96.9", "", "", "", "", "95.2"]} +{"pcdb_id": 17650, "brand_name": "Baxi", "model_name": "Megaflo 28 System ErP", "model_qualifier": "", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 78.9, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 24.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017650", "000005", "0", "2015/Jul/16 11:27", "Baxi Heating UK", "Baxi", "Megaflo 28 System ErP", "", "GC No. 41-470-21", "2015", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24", "24", "", "", "87.9", "78.9", "", "57.7", "", "2", "", "", "102", "1", "2", "125", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "87.9", "96.7", "", "", "", "", "95.0"]} +{"pcdb_id": 17651, "brand_name": "Baxi", "model_name": "Megaflo 32 System ErP", "model_qualifier": "", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 78.9, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 32.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017651", "000005", "0", "2015/Jul/16 11:28", "Baxi Heating UK", "Baxi", "Megaflo 32 System ErP", "", "GC No. 41-470-22", "2015", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "32", "32", "", "", "87.9", "78.9", "", "57.7", "", "2", "", "", "102", "1", "2", "125", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "87.8", "96.7", "", "", "", "", "95.0"]} +{"pcdb_id": 17652, "brand_name": "Baxi", "model_name": "Megaflo 15 System IE ErP", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 15.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017652", "000005", "0", "2015/Jul/16 11:28", "Baxi Heating UK", "Baxi", "Megaflo 15 System IE ErP", "", "", "2015", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "15", "15", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "95", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "96.8", "", "", "", "", "95.1"]} +{"pcdb_id": 17653, "brand_name": "Baxi", "model_name": "Megaflo 18 System IE ErP", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 18.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017653", "000005", "0", "2015/Jul/16 11:29", "Baxi Heating UK", "Baxi", "Megaflo 18 System IE ErP", "", "", "2015", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18", "18", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "105", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "96.9", "", "", "", "", "95.2"]} +{"pcdb_id": 17654, "brand_name": "Baxi", "model_name": "Megaflo 24 System IE ErP", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 24.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017654", "000005", "0", "2015/Jul/16 11:30", "Baxi Heating UK", "Baxi", "Megaflo 24 System IE ErP", "", "", "2015", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24", "24", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "115", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "96.9", "", "", "", "", "95.2"]} +{"pcdb_id": 17655, "brand_name": "Baxi", "model_name": "Platinum 24 Combi ErP", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 86.7, "comparative_hot_water_efficiency_pct": 73.5, "output_kw_max": 20.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0065, "loss_factor_f1_kwh_per_day": 1.00715, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017655", "000005", "0", "2015/Sep/21 14:23", "Baxi Heating UK", "Baxi", "Platinum 24 Combi ErP", "", "GC No. 47-077-04", "2015", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "20", "20", "", "", "88.0", "86.7", "", "73.5", "", "2", "", "", "104", "1", "2", "85", "5", "0", "", "", "0", "0", "", "", "", "", "1", "7.163", "0.085", "0.0065", "1.00715", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "87.9", "96.9", "", "", "", "", "95.2"]} +{"pcdb_id": 17656, "brand_name": "Baxi", "model_name": "Platinum 28 Combi ErP", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 86.7, "comparative_hot_water_efficiency_pct": 73.4, "output_kw_max": 24.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0072, "loss_factor_f1_kwh_per_day": 1.00979, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017656", "000005", "0", "2017/Sep/15 11:43", "Baxi Heating UK", "Baxi", "Platinum 28 Combi ErP", "", "GC No. 47-077-05", "2015", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "88.0", "86.7", "", "73.4", "", "2", "", "", "104", "1", "2", "120", "5", "0", "", "", "", "0", "", "", "", "", "1", "7.17", "0.093", "0.0072", "1.00979", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "87.9", "96.9", "", "", "", "", "95.2"]} +{"pcdb_id": 17657, "brand_name": "Baxi", "model_name": "Platinum 33 Combi ErP", "model_qualifier": "", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 86.7, "comparative_hot_water_efficiency_pct": 71.1, "output_kw_max": 28.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0047, "loss_factor_f1_kwh_per_day": 1.25141, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017657", "000005", "0", "2015/Sep/21 14:23", "Baxi Heating UK", "Baxi", "Platinum 33 Combi ErP", "", "GC No. 47-077-06", "2015", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28", "28", "", "", "87.9", "86.7", "", "71.1", "", "2", "", "", "104", "1", "2", "125", "5", "0", "", "", "", "0", "", "", "", "", "1", "7.406", "0.092", "0.0047", "1.25141", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "87.9", "96.7", "", "", "", "", "95.0"]} +{"pcdb_id": 17658, "brand_name": "Baxi", "model_name": "Platinum 40 Combi ErP", "model_qualifier": "", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 86.6, "comparative_hot_water_efficiency_pct": 68.9, "output_kw_max": 32.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0048, "loss_factor_f1_kwh_per_day": 1.48176, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017658", "000005", "0", "2015/Sep/21 14:23", "Baxi Heating UK", "Baxi", "Platinum 40 Combi ErP", "", "GC No. 47-077-07", "2015", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "32", "32", "", "", "87.9", "86.6", "", "68.9", "", "2", "", "", "104", "1", "2", "125", "5", "0", "", "", "", "0", "", "", "", "", "1", "7.649", "0.114", "0.0048", "1.48176", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "87.8", "96.7", "", "", "", "", "95.0"]} +{"pcdb_id": 17659, "brand_name": "Baxi", "model_name": "Duo-tec 24 Combi ErP", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 86.7, "comparative_hot_water_efficiency_pct": 73.5, "output_kw_max": 20.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0065, "loss_factor_f1_kwh_per_day": 1.00715, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017659", "000005", "0", "2015/Sep/21 14:23", "Baxi Heating UK", "Baxi", "Duo-tec 24 Combi ErP", "", "GC No. 47-075-96", "2015", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "20", "20", "", "", "88.0", "86.7", "", "73.5", "", "2", "", "", "104", "1", "2", "85", "5", "0", "", "", "", "0", "", "", "", "", "1", "7.163", "0.085", "0.0065", "1.00715", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "87.9", "96.9", "", "", "", "", "95.2"]} +{"pcdb_id": 17660, "brand_name": "Baxi", "model_name": "Duo-tec 28 Combi ErP", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 86.7, "comparative_hot_water_efficiency_pct": 73.4, "output_kw_max": 24.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0072, "loss_factor_f1_kwh_per_day": 1.00979, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017660", "000005", "0", "2015/Sep/21 14:23", "Baxi Heating UK", "Baxi", "Duo-tec 28 Combi ErP", "", "GC No. 47-075-97", "2015", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "88.0", "86.7", "", "73.4", "", "2", "", "", "104", "1", "2", "120", "5", "0", "", "", "", "0", "", "", "", "", "1", "7.17", "0.093", "0.0072", "1.00979", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "87.9", "96.9", "", "", "", "", "95.2"]} +{"pcdb_id": 17662, "brand_name": "Baxi", "model_name": "DUO-TEC 28 LPG COMBI ErP", "model_qualifier": "", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.4, "comparative_hot_water_efficiency_pct": 56.6, "output_kw_max": 24.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017662", "000005", "0", "2016/Jul/20 13:47", "Baxi Heating UK", "Baxi", "DUO-TEC 28 LPG COMBI ErP", "", "47-075-98", "2015", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "89.0", "80.4", "", "56.6", "", "2", "1", "", "104", "1", "2", "42", "3", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.9", "99.0", "", "", "", "", "97.3"]} +{"pcdb_id": 17663, "brand_name": "Baxi", "model_name": "Duo-tec 33 Combi ErP", "model_qualifier": "", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 86.7, "comparative_hot_water_efficiency_pct": 71.1, "output_kw_max": 28.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0047, "loss_factor_f1_kwh_per_day": 1.25141, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017663", "000005", "0", "2015/Sep/21 14:23", "Baxi Heating UK", "Baxi", "Duo-tec 33 Combi ErP", "", "GC No. 47-075-99", "2015", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28", "28", "", "", "87.9", "86.7", "", "71.1", "", "2", "", "", "104", "1", "2", "125", "5", "0", "", "", "", "0", "", "", "", "", "1", "7.406", "0.092", "0.0047", "1.25141", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "87.9", "96.7", "", "", "", "", "95.0"]} +{"pcdb_id": 17664, "brand_name": "Baxi", "model_name": "Duo-tec 40 Combi ErP", "model_qualifier": "", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 86.6, "comparative_hot_water_efficiency_pct": 68.9, "output_kw_max": 32.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0048, "loss_factor_f1_kwh_per_day": 1.48176, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017664", "000005", "0", "2015/Sep/21 14:23", "Baxi Heating UK", "Baxi", "Duo-tec 40 Combi ErP", "", "GC No. 47-077-03", "2015", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "32", "32", "", "", "87.9", "86.6", "", "68.9", "", "2", "", "", "104", "1", "2", "125", "5", "0", "", "", "", "0", "", "", "", "", "1", "7.649", "0.114", "0.0048", "1.48176", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "87.8", "96.7", "", "", "", "", "95.0"]} +{"pcdb_id": 17665, "brand_name": "Baxi", "model_name": "EcoBlue 12 Heat ErP", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 13.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017665", "000005", "0", "2015/Jul/20 10:14", "Baxi Heating UK", "Baxi", "EcoBlue 12 Heat ErP", "", "41-470-29", "2014", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "13", "13", "", "", "88.5", "79.5", "", "58.1", "", "2", "", "", "102", "1", "2", "17", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "98.0", "", "", "", "", "96.1"]} +{"pcdb_id": 17666, "brand_name": "Baxi", "model_name": "EcoBlue 15 Heat ErP", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 16.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017666", "000005", "0", "2015/Aug/14 08:58", "Baxi Heating UK", "Baxi", "EcoBlue 15 Heat ErP", "", "41-470-30", "2014", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "16", "16", "", "", "88.5", "79.5", "", "58.1", "", "2", "", "", "102", "1", "2", "20", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "98.0", "", "", "", "", "96.1"]} +{"pcdb_id": 17667, "brand_name": "Baxi", "model_name": "EcoBlue 18 Heat ErP", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 19.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017667", "000005", "0", "2015/Aug/14 09:18", "Baxi Heating UK", "Baxi", "EcoBlue 18 Heat ErP", "", "41-470-31", "2014", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "19", "19", "", "", "88.5", "79.5", "", "58.0", "", "2", "", "", "102", "1", "2", "23", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "98.0", "", "", "", "", "96.1"]} +{"pcdb_id": 17668, "brand_name": "Baxi", "model_name": "EcoBlue 21 Heat ErP", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 21.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017668", "000005", "0", "2015/Aug/14 09:19", "Baxi Heating UK", "Baxi", "EcoBlue 21 Heat ErP", "", "41-470-32", "2014", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "21", "21", "", "", "88.5", "79.5", "", "58.0", "", "2", "", "", "102", "1", "2", "25", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "98.0", "", "", "", "", "96.1"]} +{"pcdb_id": 17669, "brand_name": "Baxi", "model_name": "EcoBlue 24 Heat ErP", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 25.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017669", "000005", "0", "2015/Aug/14 09:26", "Baxi Heating UK", "Baxi", "EcoBlue 24 Heat ErP", "", "41-470-33", "2014", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "25", "25", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "33", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.7", "98.0", "", "", "", "", "96.1"]} +{"pcdb_id": 17670, "brand_name": "Baxi", "model_name": "EcoBlue Advance 13 Heat ErP", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 13.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017670", "000005", "0", "2015/Jul/20 10:26", "Baxi Heating UK", "Baxi", "EcoBlue Advance 13 Heat ErP", "", "41-470-34", "2014", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "13", "13", "", "", "88.5", "79.5", "", "58.1", "", "2", "", "", "102", "1", "2", "17", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "98.0", "", "", "", "", "96.1"]} +{"pcdb_id": 17671, "brand_name": "Baxi", "model_name": "EcoBlue Advance 16 Heat ErP", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 16.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017671", "000005", "0", "2015/Aug/14 09:27", "Baxi Heating UK", "Baxi", "EcoBlue Advance 16 Heat ErP", "", "41-470-35", "2014", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "16", "16", "", "", "88.5", "79.5", "", "58.1", "", "2", "", "", "102", "1", "2", "20", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "98.0", "", "", "", "", "96.1"]} +{"pcdb_id": 17672, "brand_name": "Baxi", "model_name": "EcoBlue Advance 19 Heat ErP", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 19.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017672", "000005", "0", "2015/Aug/14 09:28", "Baxi Heating UK", "Baxi", "EcoBlue Advance 19 Heat ErP", "", "41-470-36", "2014", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "19", "19", "", "", "88.5", "79.5", "", "58.0", "", "2", "", "", "102", "1", "2", "23", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "98.0", "", "", "", "", "96.1"]} +{"pcdb_id": 17673, "brand_name": "Baxi", "model_name": "EcoBlue Advance 25 Heat ErP", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 25.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017673", "000005", "0", "2015/Aug/14 09:28", "Baxi Heating UK", "Baxi", "EcoBlue Advance 25 Heat ErP", "", "41-470-37", "2014", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "25", "25", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "33", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.7", "98.0", "", "", "", "", "96.1"]} +{"pcdb_id": 17674, "brand_name": "Baxi", "model_name": "EcoBlue Advance 30 Heat ErP", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 30.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017674", "000005", "0", "2015/Aug/14 09:32", "Baxi Heating UK", "Baxi", "EcoBlue Advance 30 Heat ErP", "", "41-470-38", "2014", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "30", "30", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "44", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.5", "98.0", "", "", "", "", "96.0"]} +{"pcdb_id": 17675, "brand_name": "Baxi", "model_name": "MainEco 15 Heat ErP", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 16.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017675", "000005", "0", "2015/Jul/20 10:39", "Baxi Heating UK", "Baxi", "MainEco 15 Heat ErP", "", "41-470-**", "2014", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "1", "16.0", "16.0", "", "", "88.5", "79.5", "", "58.1", "", "2", "", "", "102", "1", "2", "20", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "98.0", "", "", "", "", "96.1"]} +{"pcdb_id": 17676, "brand_name": "Baxi", "model_name": "MainEco 18 Heat ErP", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 19.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017676", "000005", "0", "2015/Jul/20 10:40", "Baxi Heating UK", "Baxi", "MainEco 18 Heat ErP", "", "41-470-**", "2014", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "19.0", "19.0", "", "", "88.5", "79.5", "", "58.0", "", "2", "", "", "102", "1", "2", "23", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "98.0", "", "", "", "", "96.1"]} +{"pcdb_id": 17677, "brand_name": "Baxi", "model_name": "MainEco 24 Heat ErP", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 25.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017677", "000005", "0", "2015/Jul/20 10:42", "Baxi Heating UK", "Baxi", "MainEco 24 Heat ErP", "", "41-470-**", "2014", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "25.0", "25.0", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "33", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.7", "98.0", "", "", "", "", "96.1"]} +{"pcdb_id": 17678, "brand_name": "Baxi", "model_name": "Precision+ ErP", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 30.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017678", "000005", "0", "2015/Jul/20 10:43", "Baxi Heating UK", "Baxi", "Precision+ ErP", "", "41-470-39", "2014", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "12", "30", "", "", "88.5", "79.5", "", "58.0", "", "2", "", "", "102", "1", "2", "44", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "98.0", "", "", "", "", "96.1"]} +{"pcdb_id": 17679, "brand_name": "Vaillant", "model_name": "ecoTEC plus 832 H combi A", "model_qualifier": "VUW GB 326/5-5", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 87.0, "comparative_hot_water_efficiency_pct": 74.4, "output_kw_max": 24.4, "final_year_of_manufacture": 2017, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.003, "loss_factor_f1_kwh_per_day": 0.96947, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017679", "000031", "0", "2019/Mar/04 11:01", "Vaillant Group UK", "Vaillant", "ecoTEC plus 832 H combi A", "VUW GB 326/5-5", "47-044-58", "2015", "2017", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.4", "24.4", "", "", "88.7", "87.0", "", "74.4", "", "2", "", "", "104", "1", "2", "31", "2", "0", "", "", "0", "0", "", "", "", "", "1", "7.074", "0.119", "0.003", "0.96947", "0.0", "0.0", "", "", "", "1", "1", "", "0045", "", "", "", "", "", "", "", "", "89.0", "98.2", "", "", "", "", "96.5"]} +{"pcdb_id": 17680, "brand_name": "Vaillant", "model_name": "ecoTEC plus 832 LPG combi A", "model_qualifier": "VUW GB 326/5-5 R4", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 62.2, "output_kw_max": 24.4, "final_year_of_manufacture": 2017, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017680", "000031", "0", "2019/Mar/04 11:03", "Vaillant Group UK", "Vaillant", "ecoTEC plus 832 LPG combi A", "VUW GB 326/5-5 R4", "47-044-59", "2015", "2017", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24.4", "24.4", "", "", "88.3", "79.7", "", "62.2", "", "2", "1", "", "104", "1", "2", "85", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "", "0045", "", "", "", "", "", "", "", "", "89.4", "97.3", "", "", "", "", "95.8"]} +{"pcdb_id": 17681, "brand_name": "Vaillant", "model_name": "ecoTEC plus 838 H combi A", "model_qualifier": "VUW GB 386/5-5", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 87.0, "comparative_hot_water_efficiency_pct": 73.9, "output_kw_max": 28.6, "final_year_of_manufacture": 2017, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.003, "loss_factor_f1_kwh_per_day": 1.01583, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017681", "000031", "0", "2019/Mar/04 11:04", "Vaillant Group UK", "Vaillant", "ecoTEC plus 838 H combi A", "VUW GB 386/5-5", "47-044-60", "2015", "2017", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28.6", "28.6", "", "", "88.7", "87.0", "", "73.9", "", "2", "", "", "104", "1", "2", "38", "3", "0", "", "", "", "0", "", "", "", "", "1", "7.122", "0.126", "0.003", "1.01583", "", "", "", "", "", "1", "1", "", "0045", "", "", "", "", "", "", "", "", "89.0", "98.2", "", "", "", "", "96.5"]} +{"pcdb_id": 17682, "brand_name": "Vaillant", "model_name": "ecoTEC plus 938 H combi A", "model_qualifier": "VUI GB 386/5-5 A", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 87.0, "comparative_hot_water_efficiency_pct": 65.8, "output_kw_max": 28.6, "final_year_of_manufacture": 2017, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0, "loss_factor_f1_kwh_per_day": 1.8794, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017682", "000031", "0", "2019/Mar/04 11:04", "Vaillant Group UK", "Vaillant", "ecoTEC plus 938 H combi A", "VUI GB 386/5-5 A", "47-044-61", "2015", "2017", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28.6", "28.6", "", "", "88.7", "87.0", "", "65.8", "", "2", "", "", "104", "1", "2", "27", "5", "0", "", "", "", "0", "", "", "", "", "1", "7.998", "0.214", "0.0", "1.8794", "", "", "", "", "", "1", "1", "", "0045", "", "", "", "", "", "", "", "", "89.0", "98.2", "", "", "", "", "96.5"]} +{"pcdb_id": 17683, "brand_name": "Vaillant", "model_name": "ecoTEC pro 28 H combi A", "model_qualifier": "VUW GB 286/5-3 A", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 87.0, "comparative_hot_water_efficiency_pct": 71.0, "output_kw_max": 18.9, "final_year_of_manufacture": 2017, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0017, "loss_factor_f1_kwh_per_day": 1.30916, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017683", "000031", "0", "2019/Mar/04 11:05", "Vaillant Group UK", "Vaillant", "ecoTEC pro 28 H combi A", "VUW GB 286/5-3 A", "47-044-55", "2015", "2017", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "18.9", "18.9", "", "", "88.5", "87.0", "", "71.0", "", "2", "", "", "104", "1", "2", "32", "2", "0", "", "", "", "0", "", "", "", "", "1", "7.418", "0.103", "0.0017", "1.30916", "", "", "", "", "", "1", "1", "", "0045", "", "", "", "", "", "", "", "", "89.0", "97.8", "", "", "", "", "96.1"]} +{"pcdb_id": 17684, "brand_name": "Vaillant", "model_name": "ecoTEC plus 612 H system A", "model_qualifier": "VU GB 126/5-5 A", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 12.2, "final_year_of_manufacture": 2017, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017684", "000031", "0", "2019/Mar/04 10:56", "Vaillant Group UK", "Vaillant", "ecoTEC plus 612 H system A", "VU GB 126/5-5 A", "41-044-78", "2015", "2017", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "12.2", "12.2", "", "", "88.3", "79.3", "", "57.9", "", "2", "", "", "102", "1", "2", "18", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0045", "", "", "", "", "", "", "", "", "88.7", "97.3", "", "", "", "", "95.7"]} +{"pcdb_id": 17685, "brand_name": "Vaillant", "model_name": "ecoTEC plus 615 H system A", "model_qualifier": "VU GB 156/5-5 A", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 15.4, "final_year_of_manufacture": 2017, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017685", "000031", "0", "2019/Mar/04 10:56", "Vaillant Group UK", "Vaillant", "ecoTEC plus 615 H system A", "VU GB 156/5-5 A", "41-044-79", "2015", "2017", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "15.4", "15.4", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "31", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0045", "", "", "", "", "", "", "", "", "89.4", "97.3", "", "", "", "", "95.8"]} +{"pcdb_id": 17686, "brand_name": "Vaillant", "model_name": "ecoTEC plus 618 H system A", "model_qualifier": "VU GB 186/5-5 A", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 18.5, "final_year_of_manufacture": 2017, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017686", "000031", "0", "2019/Mar/04 10:56", "Vaillant Group UK", "Vaillant", "ecoTEC plus 618 H system A", "VU GB 186/5-5 A", "41-044-80", "2015", "2017", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18.5", "18.5", "", "", "88.6", "79.6", "", "58.2", "", "2", "", "", "102", "1", "2", "31", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0045", "", "", "", "", "", "", "", "", "89.5", "97.8", "", "", "", "", "96.2"]} +{"pcdb_id": 17687, "brand_name": "Vaillant", "model_name": "ecoTEC pro 28 LPG combi A", "model_qualifier": "VUW GB 286/5-3 A R4", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 62.1, "output_kw_max": 18.9, "final_year_of_manufacture": 2017, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017687", "000031", "0", "2019/Mar/04 11:06", "Vaillant Group UK", "Vaillant", "ecoTEC pro 28 LPG combi A", "VUW GB 286/5-3 A R4", "47-044-56", "2015", "2017", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "18.9", "18.9", "", "", "88.2", "79.6", "", "62.1", "", "2", "1", "", "104", "1", "2", "80", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "", "0045", "", "", "", "", "", "", "", "", "89.5", "97.0", "", "", "", "", "95.6"]} +{"pcdb_id": 17688, "brand_name": "Vaillant", "model_name": "ecoTEC pro 30 H combi A", "model_qualifier": "VUW GB 306/5-3", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 87.0, "comparative_hot_water_efficiency_pct": 73.2, "output_kw_max": 24.7, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0008, "loss_factor_f1_kwh_per_day": 1.09904, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017688", "000031", "0", "2015/Sep/21 14:23", "Vaillant Group UK", "Vaillant", "ecoTEC pro 30 H combi A", "VUW GB 306/5-3", "47-044-52", "2015", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.7", "24.7", "", "", "88.7", "87.0", "", "73.2", "", "2", "", "", "104", "1", "2", "38", "3", "0", "", "", "", "0", "", "", "", "", "1", "7.195", "0.095", "0.0008", "1.09904", "", "", "", "", "", "", "", "", "0045", "", "", "", "", "", "", "", "", "89.0", "98.0", "", "", "", "", "96.3"]} +{"pcdb_id": 17689, "brand_name": "Vaillant", "model_name": "ecoTEC plus 618 LPG system A", "model_qualifier": "VU GB 186/5-5 A R4", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 18.5, "final_year_of_manufacture": 2017, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017689", "000031", "0", "2019/Mar/04 10:57", "Vaillant Group UK", "Vaillant", "ecoTEC plus 618 LPG system A", "VU GB 186/5-5 A R4", "41-044-81", "2015", "2017", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "18.5", "18.5", "", "", "88.4", "79.4", "", "58.0", "", "2", "1", "", "102", "1", "2", "65", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0045", "", "", "", "", "", "", "", "", "89.7", "97.5", "", "", "", "", "96.0"]} +{"pcdb_id": 17690, "brand_name": "Vaillant", "model_name": "ecoTEC plus 624 H system A", "model_qualifier": "VU GB 246/5-5 A", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 24.4, "final_year_of_manufacture": 2017, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017690", "000031", "0", "2019/Mar/04 10:57", "Vaillant Group UK", "Vaillant", "ecoTEC plus 624 H system A", "VU GB 246/5-5 A", "41-044-82", "2015", "2017", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24.4", "24.4", "", "", "88.7", "79.7", "", "58.2", "", "2", "", "", "102", "1", "2", "31", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0045", "", "", "", "", "", "", "", "", "89.0", "98.2", "", "", "", "", "96.5"]} +{"pcdb_id": 17691, "brand_name": "Vaillant", "model_name": "ecoTEC plus 630 H system A", "model_qualifier": "VU GB 306/5-5 A", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 30.4, "final_year_of_manufacture": 2017, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017691", "000031", "0", "2019/Mar/04 10:57", "Vaillant Group UK", "Vaillant", "ecoTEC plus 630 H system A", "VU GB 306/5-5 A", "41-044-83", "2015", "2017", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "30.4", "30.4", "", "", "88.7", "79.7", "", "58.2", "", "2", "", "", "102", "1", "2", "34", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0045", "", "", "", "", "", "", "", "", "88.7", "98.2", "", "", "", "", "96.4"]} +{"pcdb_id": 17692, "brand_name": "Vaillant", "model_name": "ecoTEC plus 630 LPG system A", "model_qualifier": "VU GB 306/5-5 A R4", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 30.4, "final_year_of_manufacture": 2017, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017692", "000031", "0", "2019/Mar/04 11:00", "Vaillant Group UK", "Vaillant", "ecoTEC plus 630 LPG system A", "VU GB 306/5-5 A R4", "41-044-84", "2015", "2017", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "30.4", "30.4", "", "", "88.4", "79.4", "", "58.0", "", "2", "1", "", "102", "1", "2", "80", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0045", "", "", "", "", "", "", "", "", "89.4", "97.6", "", "", "", "", "96.1"]} +{"pcdb_id": 17693, "brand_name": "Vaillant", "model_name": "ecoTEC plus 637 H system A", "model_qualifier": "VU GB 376/5-5 A", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 37.6, "final_year_of_manufacture": 2017, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017693", "000031", "0", "2019/Mar/04 11:00", "Vaillant Group UK", "Vaillant", "ecoTEC plus 637 H system A", "VU GB 376/5-5 A", "41-044-85", "2015", "2017", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "37.6", "37.6", "", "", "88.5", "79.5", "", "58.1", "", "2", "", "", "102", "1", "2", "38", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0045", "", "", "", "", "", "", "", "", "88.8", "97.8", "", "", "", "", "96.1"]} +{"pcdb_id": 17694, "brand_name": "Potterton", "model_name": "Gold 24 Combi ErP", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 86.7, "comparative_hot_water_efficiency_pct": 73.5, "output_kw_max": 20.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0065, "loss_factor_f1_kwh_per_day": 1.00715, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017694", "000005", "0", "2015/Sep/21 14:23", "Baxi Heating UK", "Potterton", "Gold 24 Combi ErP", "", "GC No. 47-393-43", "2015", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "20", "20", "", "", "88.0", "86.7", "", "73.5", "", "2", "", "", "104", "1", "2", "85", "5", "0", "", "", "", "0", "", "", "", "", "1", "7.163", "0.085", "0.0065", "1.00715", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "87.9", "96.9", "", "", "", "", "95.2"]} +{"pcdb_id": 17695, "brand_name": "Potterton", "model_name": "Gold 28 Combi ErP", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 86.7, "comparative_hot_water_efficiency_pct": 73.4, "output_kw_max": 24.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0072, "loss_factor_f1_kwh_per_day": 1.00979, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017695", "000005", "0", "2015/Sep/21 14:23", "Baxi Heating UK", "Potterton", "Gold 28 Combi ErP", "", "GC No. 47-393-44", "2015", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "88.0", "86.7", "", "73.4", "", "2", "", "", "104", "1", "2", "120", "5", "0", "", "", "", "0", "", "", "", "", "1", "7.17", "0.093", "0.0072", "1.00979", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "87.9", "96.9", "", "", "", "", "95.2"]} +{"pcdb_id": 17696, "brand_name": "Potterton", "model_name": "Gold 33 Combi ErP", "model_qualifier": "", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 86.7, "comparative_hot_water_efficiency_pct": 71.1, "output_kw_max": 28.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0047, "loss_factor_f1_kwh_per_day": 1.25141, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017696", "000005", "0", "2015/Sep/21 14:23", "Baxi Heating UK", "Potterton", "Gold 33 Combi ErP", "", "GC No. 47-393-46", "2015", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28", "28", "", "", "87.9", "86.7", "", "71.1", "", "2", "", "", "104", "1", "2", "125", "5", "0", "", "", "", "0", "", "", "", "", "1", "7.406", "0.092", "0.0047", "1.25141", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "87.9", "96.7", "", "", "", "", "95.0"]} +{"pcdb_id": 17697, "brand_name": "Potterton", "model_name": "GOLD 28 LPG COMBI ErP", "model_qualifier": "", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.4, "comparative_hot_water_efficiency_pct": 56.6, "output_kw_max": 24.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017697", "000005", "0", "2016/Jul/20 13:46", "Baxi Heating UK", "Potterton", "GOLD 28 LPG COMBI ErP", "", "47-393-45", "2015", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "89.0", "80.4", "", "56.6", "", "2", "1", "", "104", "1", "2", "42", "3", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.9", "99.0", "", "", "", "", "97.3"]} +{"pcdb_id": 17698, "brand_name": "Potterton", "model_name": "Gold 18 System ErP", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 18.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017698", "000005", "0", "2015/Jul/17 13:42", "Baxi Heating UK", "Potterton", "Gold 18 System ErP", "", "GC No. 41-592-39", "2015", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18", "18", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "105", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "96.9", "", "", "", "", "95.2"]} +{"pcdb_id": 17699, "brand_name": "Potterton", "model_name": "Gold 24 System ErP", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 24.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017699", "000005", "0", "2015/Jul/17 13:42", "Baxi Heating UK", "Potterton", "Gold 24 System ErP", "", "GC No.41-592-40", "2015", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24", "24", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "115", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "96.9", "", "", "", "", "95.2"]} +{"pcdb_id": 17700, "brand_name": "Potterton", "model_name": "Gold 28 System ErP", "model_qualifier": "", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 78.9, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 28.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017700", "000005", "0", "2015/Jul/17 13:43", "Baxi Heating UK", "Potterton", "Gold 28 System ErP", "", "GC No. 41-592-41", "2015", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "28", "28", "", "", "87.9", "78.9", "", "57.7", "", "2", "", "", "102", "1", "2", "125", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "96.7", "", "", "", "", "95.0"]} +{"pcdb_id": 17701, "brand_name": "Potterton", "model_name": "Titanium 24 Combi ErP", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 86.7, "comparative_hot_water_efficiency_pct": 73.5, "output_kw_max": 20.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0065, "loss_factor_f1_kwh_per_day": 1.00715, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017701", "000005", "0", "2015/Sep/21 14:23", "Baxi Heating UK", "Potterton", "Titanium 24 Combi ErP", "", "GC No. 47-393-50", "2015", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "20", "20", "", "", "88.0", "86.7", "", "73.5", "", "2", "", "", "104", "1", "2", "85", "5", "0", "", "", "", "0", "", "", "", "", "1", "7.163", "0.85", "0.0065", "1.00715", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "87.9", "96.9", "", "", "", "", "95.2"]} +{"pcdb_id": 17702, "brand_name": "Potterton", "model_name": "Titanium 28 Combi ErP", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 86.7, "comparative_hot_water_efficiency_pct": 73.4, "output_kw_max": 24.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0072, "loss_factor_f1_kwh_per_day": 1.00979, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017702", "000005", "0", "2015/Sep/21 14:23", "Baxi Heating UK", "Potterton", "Titanium 28 Combi ErP", "", "GC No. 47-393-51", "2015", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "88.0", "86.7", "", "73.4", "", "2", "", "", "104", "1", "2", "120", "5", "0", "", "", "", "0", "", "", "", "", "1", "7.17", "0.093", "0.0072", "1.00979", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "87.9", "96.9", "", "", "", "", "95.2"]} +{"pcdb_id": 17703, "brand_name": "Potterton", "model_name": "Titanium 33 Combi ErP", "model_qualifier": "", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 86.7, "comparative_hot_water_efficiency_pct": 71.1, "output_kw_max": 28.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0047, "loss_factor_f1_kwh_per_day": 1.25141, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017703", "000005", "0", "2015/Sep/21 14:23", "Baxi Heating UK", "Potterton", "Titanium 33 Combi ErP", "", "GC No. 47-393-52", "2015", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28", "28", "", "", "87.9", "86.7", "", "71.1", "", "2", "", "", "104", "1", "2", "125", "5", "0", "", "", "", "0", "", "", "", "", "1", "7.406", "0.092", "0.0047", "1.25141", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "87.9", "96.7", "", "", "", "", "95.0"]} +{"pcdb_id": 17704, "brand_name": "Potterton", "model_name": "Titanium 40 Combi ErP", "model_qualifier": "", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 86.6, "comparative_hot_water_efficiency_pct": 68.9, "output_kw_max": 32.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0048, "loss_factor_f1_kwh_per_day": 1.48176, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017704", "000005", "0", "2015/Sep/21 14:23", "Baxi Heating UK", "Potterton", "Titanium 40 Combi ErP", "", "GC No. 47-393-53", "2015", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "32", "32", "", "", "87.9", "86.6", "", "68.9", "", "2", "", "", "104", "1", "2", "125", "5", "0", "", "", "", "0", "", "", "", "", "1", "7.649", "0.114", "0.0048", "1.48176", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "87.8", "96.7", "", "", "", "", "95.0"]} +{"pcdb_id": 17705, "brand_name": "Viessmann", "model_name": "Vitodens 200-W B2HA-19", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 17.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017705", "000033", "0", "2016/Feb/15 13:10", "Viessmann", "Viessmann", "Vitodens 200-W B2HA-19", "", "", "2013", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "17.5", "17.5", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "65", "4.21", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "97.8", "", "", "", "", "95.9"]} +{"pcdb_id": 17706, "brand_name": "Viessmann", "model_name": "Vitodens 200-W B2HA-26", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 24.1, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017706", "000033", "0", "2016/Feb/15 13:10", "Viessmann", "Viessmann", "Vitodens 200-W B2HA-26", "", "", "2013", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24.1", "24.1", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "103", "4.21", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "97.8", "", "", "", "", "96.0"]} +{"pcdb_id": 17707, "brand_name": "Viessmann", "model_name": "Vitodens 200-W B2HA-30", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 27.8, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017707", "000033", "0", "2016/Feb/15 13:10", "Viessmann", "Viessmann", "Vitodens 200-W B2HA-30", "", "", "2013", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "27.8", "27.8", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "106", "4.21", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.2", "97.8", "", "", "", "", "96.0"]} +{"pcdb_id": 17708, "brand_name": "Viessmann", "model_name": "Vitodens 200-W B2HA-35", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 32.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017708", "000033", "0", "2016/Feb/15 13:09", "Viessmann", "Viessmann", "Vitodens 200-W B2HA-35", "", "", "2013", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "32.2", "32.2", "", "", "88.5", "79.5", "", "58.1", "", "2", "", "", "102", "1", "2", "119", "4.21", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "98.0", "", "", "", "", "96.1"]} +{"pcdb_id": 17709, "brand_name": "Viessmann", "model_name": "Vitodens 200-W B2KA-26", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 56.1, "output_kw_max": 24.1, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017709", "000033", "0", "2016/Feb/15 13:09", "Viessmann", "Viessmann", "Vitodens 200-W B2KA-26", "", "47-819-28", "2013", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.1", "24.1", "", "", "88.4", "79.8", "", "56.1", "", "2", "", "", "104", "1", "2", "116", "4.21", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "97.8", "", "", "", "", "96.0"]} +{"pcdb_id": 17710, "brand_name": "Viessmann", "model_name": "Vitodens 200-W B2KA-30", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 56.2, "output_kw_max": 27.8, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017710", "000033", "0", "2016/Feb/15 13:09", "Viessmann", "Viessmann", "Vitodens 200-W B2KA-30", "", "47-819-29", "2013", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "27.8", "27.8", "", "", "88.4", "79.8", "", "56.2", "", "2", "", "", "104", "1", "2", "116", "4.21", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.2", "97.8", "", "", "", "", "96.0"]} +{"pcdb_id": 17711, "brand_name": "Viessmann", "model_name": "Vitodens 200-W B2KA-35", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 56.2, "output_kw_max": 32.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017711", "000033", "0", "2016/Feb/15 13:09", "Viessmann", "Viessmann", "Vitodens 200-W B2KA-35", "", "", "2013", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "32.2", "32.2", "", "", "88.5", "79.9", "", "56.2", "", "2", "", "", "104", "1", "2", "126", "4.21", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "98.0", "", "", "", "", "96.1"]} +{"pcdb_id": 17712, "brand_name": "Viessmann", "model_name": "Vitodens 222-F B2TA-19", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 81.1, "comparative_hot_water_efficiency_pct": 52.8, "output_kw_max": 17.2, "final_year_of_manufacture": 2016, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017712", "000033", "0", "2024/Jan/31 10:17", "Viessmann", "Viessmann", "Vitodens 222-F B2TA-19", "", "47-819-15", "2013", "2016", "1", "1", "1", "2", "0", "", "", "2", "2", "2", "17.2", "17.2", "", "", "88.4", "81.1", "", "52.8", "", "2", "", "", "106", "1", "2", "156", "4.21", "2", "", "", "100", "0", "50", "2", "60", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "97.8", "", "", "", "", "95.9"]} +{"pcdb_id": 17713, "brand_name": "Viessmann", "model_name": "Vitodens 222-F B2TA-26", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 81.1, "comparative_hot_water_efficiency_pct": 52.9, "output_kw_max": 23.7, "final_year_of_manufacture": 2016, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017713", "000033", "0", "2024/Jan/31 10:17", "Viessmann", "Viessmann", "Vitodens 222-F B2TA-26", "", "47-819-16", "2013", "2016", "1", "1", "1", "2", "0", "", "", "2", "2", "2", "23.7", "23.7", "", "", "88.4", "81.1", "", "52.9", "", "2", "", "", "106", "1", "2", "105", "4.21", "2", "", "", "100", "0", "50", "2", "60", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "97.8", "", "", "", "", "96.0"]} +{"pcdb_id": 17714, "brand_name": "Viessmann", "model_name": "Vitodens 222-F B2TA-35", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 81.2, "comparative_hot_water_efficiency_pct": 52.9, "output_kw_max": 31.7, "final_year_of_manufacture": 2016, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017714", "000033", "0", "2024/Jan/31 10:17", "Viessmann", "Viessmann", "Vitodens 222-F B2TA-35", "", "47-819-17", "2013", "2016", "1", "1", "1", "2", "0", "", "", "2", "2", "2", "31.7", "31.7", "", "", "88.5", "81.2", "", "52.9", "", "2", "", "", "106", "1", "2", "156", "4.21", "2", "", "", "100", "0", "50", "2", "60", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "98.0", "", "", "", "", "96.1"]} +{"pcdb_id": 17717, "brand_name": "Viessmann", "model_name": "Vitodens 100-W B1HA-19", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 17.3, "final_year_of_manufacture": 2016, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017717", "000033", "0", "2016/Mar/09 14:09", "Viessmann", "Viessmann", "Vitodens 100-W B1HA-19", "", "41-819-36", "2014", "2016", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "17.3", "17.3", "", "", "88.5", "79.5", "", "58.1", "", "2", "", "", "102", "1", "2", "84", "4.92", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.2", "97.9", "", "", "", "", "96.1"]} +{"pcdb_id": 17718, "brand_name": "Viessmann", "model_name": "Vitodens 100-W B1HA-26", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 23.7, "final_year_of_manufacture": 2016, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017718", "000033", "0", "2016/Mar/09 14:09", "Viessmann", "Viessmann", "Vitodens 100-W B1HA-26", "", "41-819-37", "2014", "2016", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "23.7", "23.7", "", "", "88.5", "79.5", "", "58.0", "", "2", "", "", "102", "1", "2", "92", "4.92", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "97.8", "", "", "", "", "96.0"]} +{"pcdb_id": 17719, "brand_name": "Viessmann", "model_name": "Vitodens 100-W B1HA-30", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 27.3, "final_year_of_manufacture": 2016, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017719", "000033", "0", "2016/Mar/09 14:10", "Viessmann", "Viessmann", "Vitodens 100-W B1HA-30", "", "41-819-38", "2014", "2016", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "27.3", "27.3", "", "", "88.3", "79.3", "", "57.9", "", "2", "", "", "102", "1", "2", "98", "4.76", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "97.5", "", "", "", "", "95.7"]} +{"pcdb_id": 17720, "brand_name": "Viessmann", "model_name": "Vitodens 100-W B1HA-35", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 31.9, "final_year_of_manufacture": 2016, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017720", "000033", "0", "2016/Mar/09 14:10", "Viessmann", "Viessmann", "Vitodens 100-W B1HA-35", "", "41-819-39", "2014", "2016", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "31.9", "31.9", "", "", "88.5", "79.5", "", "58.1", "", "2", "", "", "102", "1", "2", "108", "4.92", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.2", "98.0", "", "", "", "", "96.2"]} +{"pcdb_id": 17721, "brand_name": "Viessmann", "model_name": "Vitodens 100-W B1KA-26", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 56.2, "output_kw_max": 23.7, "final_year_of_manufacture": 2016, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017721", "000033", "0", "2016/Mar/09 14:10", "Viessmann", "Viessmann", "Vitodens 100-W B1KA-26", "", "47-819-33", "2014", "2016", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "23.7", "23.7", "", "", "88.5", "79.9", "", "56.2", "", "2", "", "", "104", "1", "2", "97", "4.92", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "97.8", "", "", "", "", "96.0"]} +{"pcdb_id": 17722, "brand_name": "Viessmann", "model_name": "Vitodens 100-W B1KA-30", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 56.1, "output_kw_max": 27.3, "final_year_of_manufacture": 2016, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017722", "000033", "0", "2016/Mar/09 14:10", "Viessmann", "Viessmann", "Vitodens 100-W B1KA-30", "", "47-819-34", "2014", "2016", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "27.3", "27.3", "", "", "88.3", "79.7", "", "56.1", "", "2", "", "", "104", "1", "2", "105", "4.76", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "97.5", "", "", "", "", "95.7"]} +{"pcdb_id": 17723, "brand_name": "Viessmann", "model_name": "Vitodens 100-W B1KA-35", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 56.2, "output_kw_max": 31.9, "final_year_of_manufacture": 2016, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017723", "000033", "0", "2016/Mar/09 14:10", "Viessmann", "Viessmann", "Vitodens 100-W B1KA-35", "", "47-819-35", "2014", "2016", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "31.9", "31.9", "", "", "88.5", "79.9", "", "56.2", "", "2", "", "", "104", "1", "2", "119", "4.92", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.2", "98.0", "", "", "", "", "96.2"]} +{"pcdb_id": 17726, "brand_name": "Viessmann", "model_name": "Vitodens 050-W BPJD", "model_qualifier": "29kW Combi Boiler", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 62.3, "output_kw_max": 21.9, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017726", "000033", "0", "2018/Feb/19 13:43", "Viessmann", "Viessmann", "Vitodens 050-W BPJD", "29kW Combi Boiler", "47-819-38", "2014", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "21.9", "21.9", "", "", "88.4", "79.8", "", "62.3", "", "2", "", "", "104", "1", "2", "97", "2.71", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "", "0035", "", "", "", "", "", "", "", "", "87.8", "98.0", "", "", "", "", "96.1"]} +{"pcdb_id": 17728, "brand_name": "Viessmann", "model_name": "Vitodens 050-W BPJD", "model_qualifier": "35kW Combi Boiler", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 62.3, "output_kw_max": 30.1, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017728", "000033", "0", "2018/Feb/19 13:42", "Viessmann", "Viessmann", "Vitodens 050-W BPJD", "35kW Combi Boiler", "47-819-39", "2014", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "30.1", "30.1", "", "", "88.4", "79.8", "", "62.3", "", "2", "", "", "104", "1", "2", "141", "2.71", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "", "0035", "", "", "", "", "", "", "", "", "87.8", "97.9", "", "", "", "", "96.0"]} +{"pcdb_id": 17729, "brand_name": "Glow-worm", "model_name": "HOME 25c", "model_qualifier": "", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 77.0, "output_kw_max": 15.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0095, "loss_factor_f1_kwh_per_day": 0.71853, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017729", "000207", "0", "2017/Aug/17 12:47", "Glow-worm", "Glow-worm", "HOME 25c", "", "47-019-29", "2015", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "15.2", "15.2", "", "", "88.7", "87.3", "", "77.0", "", "2", "", "", "104", "1", "2", "19", "2", "0", "", "", "", "0", "", "", "", "", "1", "6.835", "0.096", "0.0095", "0.71853", "", "", "", "", "", "1", "1", "", "0085", "", "", "", "", "", "", "", "", "89.7", "97.8", "", "", "", "", "96.2"]} +{"pcdb_id": 17730, "brand_name": "Glow-worm", "model_name": "HOME 30c", "model_qualifier": "", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 75.8, "output_kw_max": 15.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0115, "loss_factor_f1_kwh_per_day": 0.81337, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017730", "000207", "0", "2017/Aug/17 12:40", "Glow-worm", "Glow-worm", "HOME 30c", "", "47-019-30", "2015", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "15.2", "15.2", "", "", "88.7", "87.3", "", "75.8", "", "2", "", "", "104", "1", "2", "19", "2", "0", "", "", "", "0", "", "", "", "", "1", "6.945", "0.085", "0.0115", "0.81337", "", "", "", "", "", "1", "1", "", "0085", "", "", "", "", "", "", "", "", "89.7", "97.8", "", "", "", "", "96.2"]} +{"pcdb_id": 17731, "brand_name": "Glow-worm", "model_name": "HOME 35c", "model_qualifier": "", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 76.1, "output_kw_max": 15.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0045, "loss_factor_f1_kwh_per_day": 0.83104, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017731", "000207", "0", "2017/Jun/23 12:30", "Glow-worm", "Glow-worm", "HOME 35c", "", "47-019-31", "2015", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "15.2", "15.2", "", "", "88.7", "87.3", "", "76.1", "", "2", "", "", "104", "1", "2", "17", "2", "0", "", "", "", "0", "", "", "", "", "1", "6.921", "0.096", "0.0045", "0.83104", "", "", "", "", "", "1", "1", "", "0085", "", "", "", "", "", "", "", "", "89.7", "97.8", "", "", "", "", "96.2"]} +{"pcdb_id": 17732, "brand_name": "Glow-worm", "model_name": "SUSTAIN 25c", "model_qualifier": "", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 77.0, "output_kw_max": 18.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0095, "loss_factor_f1_kwh_per_day": 0.71853, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017732", "000207", "0", "2017/Aug/17 12:47", "Glow-worm", "Glow-worm", "SUSTAIN 25c", "", "47-109-32", "2015", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "18.3", "18.3", "", "", "88.7", "87.3", "", "77.0", "", "2", "", "", "104", "1", "2", "25", "2", "0", "", "", "", "0", "", "", "", "", "1", "6.835", "0.096", "0.0095", "0.71853", "", "", "", "", "", "1", "1", "", "0085", "", "", "", "", "", "", "", "", "89.7", "97.8", "", "", "", "", "96.2"]} +{"pcdb_id": 17733, "brand_name": "Glow-worm", "model_name": "SUSTAIN 30c", "model_qualifier": "", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 75.8, "output_kw_max": 18.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0115, "loss_factor_f1_kwh_per_day": 0.81337, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017733", "000207", "0", "2017/Aug/17 12:50", "Glow-worm", "Glow-worm", "SUSTAIN 30c", "", "47-019-33", "2015", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "18.3", "18.3", "", "", "88.7", "87.3", "", "75.8", "", "2", "", "", "104", "1", "2", "21", "2", "0", "", "", "", "0", "", "", "", "", "1", "6.945", "0.085", "0.0115", "0.81337", "", "", "", "", "", "1", "1", "", "0085", "", "", "", "", "", "", "", "", "89.7", "97.8", "", "", "", "", "96.2"]} +{"pcdb_id": 17734, "brand_name": "Glow-worm", "model_name": "SUSTAIN 35c", "model_qualifier": "", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 76.1, "output_kw_max": 18.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0045, "loss_factor_f1_kwh_per_day": 0.83104, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017734", "000207", "0", "2017/Jun/23 12:32", "Glow-worm", "Glow-worm", "SUSTAIN 35c", "", "47-019-34", "2015", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "18.3", "18.3", "", "", "88.7", "87.3", "", "76.1", "", "2", "", "", "104", "1", "2", "75", "2", "0", "", "", "", "0", "", "", "", "", "1", "6.921", "0.096", "0.0045", "0.83104", "", "", "", "", "", "1", "1", "", "0085", "", "", "", "", "", "", "", "", "89.7", "97.8", "", "", "", "", "96.2"]} +{"pcdb_id": 17735, "brand_name": "Baxi", "model_name": "Solo 30 Heat IE ErP", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 30.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017735", "000005", "0", "2015/Jul/17 13:45", "Baxi Heating UK", "Baxi", "Solo 30 Heat IE ErP", "", "", "2006", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "30.2", "30.2", "", "", "88.1", "79.1", "", "57.8", "", "2", "", "", "102", "1", "2", "80", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.4", "96.4", "", "", "", "", "95.1"]} +{"pcdb_id": 17736, "brand_name": "Baxi", "model_name": "Solo 24 Heat IE ErP", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 22.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017736", "000005", "0", "2017/Aug/17 12:51", "Baxi Heating UK", "Baxi", "Solo 24 Heat IE ErP", "", "", "2006", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "22", "22", "", "", "88.1", "79.1", "", "57.8", "", "2", "", "", "102", "1", "2", "80", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.5", "96.5", "", "", "", "", "95.2"]} +{"pcdb_id": 17737, "brand_name": "Baxi", "model_name": "Solo 18 Heat IE ErP", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 17.81, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017737", "000005", "0", "2015/Jul/17 13:44", "Baxi Heating UK", "Baxi", "Solo 18 Heat IE ErP", "", "", "2006", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "17.81", "17.81", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "80", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "96.8", "", "", "", "", "95.2"]} +{"pcdb_id": 17738, "brand_name": "Baxi", "model_name": "Solo 15 Heat IE ErP", "model_qualifier": "", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 15.24, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017738", "000005", "0", "2015/Jul/17 13:44", "Baxi Heating UK", "Baxi", "Solo 15 Heat IE ErP", "", "", "2006", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "15.24", "15.24", "", "", "88.7", "79.7", "", "58.2", "", "2", "", "", "102", "1", "2", "80", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.3", "97.7", "", "", "", "", "96.3"]} +{"pcdb_id": 17739, "brand_name": "Baxi", "model_name": "Solo 12 Heat IE ErP", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 11.82, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017739", "000005", "0", "2015/Jul/17 13:44", "Baxi Heating UK", "Baxi", "Solo 12 Heat IE ErP", "", "", "2006", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "11.82", "11.82", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "80", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.6", "96.5", "", "", "", "", "95.0"]} +{"pcdb_id": 17740, "brand_name": "Potterton", "model_name": "Promax 24 Combi ErP", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 73.5, "output_kw_max": 20.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0065, "loss_factor_f1_kwh_per_day": 1.06103, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017740", "000005", "0", "2015/Sep/21 14:23", "Baxi Heating UK", "Potterton", "Promax 24 Combi ErP", "", "CG No. 47-393-47", "2008", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "20", "20", "", "", "88.4", "87.3", "", "73.5", "", "2", "", "", "104", "1", "2", "85", "5", "0", "", "", "", "0", "", "", "", "", "1", "7.163", "0.085", "0.0065", "1.06103", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "90.0", "96.9", "", "", "", "", "95.6"]} +{"pcdb_id": 17741, "brand_name": "Potterton", "model_name": "Promax 28 Combi ErP", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 73.4, "output_kw_max": 24.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0072, "loss_factor_f1_kwh_per_day": 1.06372, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017741", "000005", "0", "2015/Sep/21 14:23", "Baxi Heating UK", "Potterton", "Promax 28 Combi ErP", "", "GC No. 47-393-48", "2008", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "88.4", "87.3", "", "73.4", "", "2", "", "", "104", "1", "2", "120", "5", "0", "", "", "", "0", "", "", "", "", "1", "7.17", "0.093", "0.0072", "1.06372", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "90.0", "96.9", "", "", "", "", "95.6"]} +{"pcdb_id": 17742, "brand_name": "Potterton", "model_name": "Promax 33 Combi ErP", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 71.1, "output_kw_max": 28.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0047, "loss_factor_f1_kwh_per_day": 1.30711, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017742", "000005", "0", "2015/Sep/21 14:23", "Baxi Heating UK", "Potterton", "Promax 33 Combi ErP", "", "GC No. 47-393-49", "2008", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28", "28", "", "", "88.3", "87.3", "", "71.1", "", "2", "", "", "104", "1", "2", "125", "5", "0", "", "", "", "0", "", "", "", "", "1", "7.406", "0.092", "0.0047", "1.30711", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "90.0", "96.7", "", "", "", "", "95.4"]} +{"pcdb_id": 17743, "brand_name": "Potterton", "model_name": "Promax 12 System ErP", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 12.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017743", "000005", "0", "2015/Jul/29 16:46", "Baxi Heating UK", "Potterton", "Promax 12 System ErP", "", "GC No. 41-592-42", "2008", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "12.4", "12.4", "", "", "88.3", "79.3", "", "57.9", "", "2", "", "", "102", "1", "2", "110", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "89.9", "96.7", "", "", "", "", "95.4"]} +{"pcdb_id": 17744, "brand_name": "Potterton", "model_name": "Promax 15 System ErP", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 15.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017744", "000005", "0", "2015/Jul/29 16:46", "Baxi Heating UK", "Potterton", "Promax 15 System ErP", "", "GC No. 41-592-43", "2008", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "15", "15", "", "", "88.3", "79.3", "", "57.9", "", "2", "", "", "102", "1", "2", "95", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "89.9", "96.8", "", "", "", "", "95.5"]} +{"pcdb_id": 17745, "brand_name": "Potterton", "model_name": "Promax 18 System ErP", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 18.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017745", "000005", "0", "2015/Jul/29 16:46", "Baxi Heating UK", "Potterton", "Promax 18 System ErP", "", "GC No. 41-592-44", "2008", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18", "18", "", "", "88.3", "79.3", "", "58.0", "", "2", "", "", "102", "1", "2", "105", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "89.9", "96.9", "", "", "", "", "95.5"]} +{"pcdb_id": 17746, "brand_name": "Potterton", "model_name": "Promax 24 System ErP", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 24.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017746", "000005", "0", "2015/Jul/29 16:50", "Baxi Heating UK", "Potterton", "Promax 24 System ErP", "", "GC No. 41-592-45", "2008", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24", "24", "", "", "88.3", "79.3", "", "58.0", "", "2", "", "", "102", "1", "2", "115", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "89.9", "96.9", "", "", "", "", "95.5"]} +{"pcdb_id": 17747, "brand_name": "Potterton", "model_name": "Promax 32 System ErP", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 32.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017747", "000005", "0", "2015/Jul/29 16:51", "Baxi Heating UK", "Potterton", "Promax 32 System ErP", "", "GC No. 41-592-46", "2008", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "32", "32", "", "", "88.3", "79.3", "", "57.9", "", "2", "", "", "102", "0", "2", "125", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "89.9", "96.7", "", "", "", "", "95.4"]} +{"pcdb_id": 17749, "brand_name": "Glow-worm", "model_name": "HOME 12s", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 12.1, "final_year_of_manufacture": 2016, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017749", "000207", "0", "2017/Jun/15 09:27", "Glow-worm", "Glow-worm", "HOME 12s", "", "41-019-27", "2015", "2016", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "12.1", "12.1", "", "", "88.6", "79.6", "", "58.2", "", "2", "", "", "102", "1", "2", "105", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0085", "", "", "", "", "", "", "", "", "89.6", "97.8", "", "", "", "", "96.2"]} +{"pcdb_id": 17750, "brand_name": "Glow-worm", "model_name": "HOME 15s", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 15.2, "final_year_of_manufacture": 2016, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017750", "000207", "0", "2017/Jun/15 09:28", "Glow-worm", "Glow-worm", "HOME 15s", "", "41-019-28", "2015", "2016", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "15.2", "15.2", "", "", "88.6", "79.6", "", "58.2", "", "2", "", "", "102", "1", "2", "105", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0085", "", "", "", "", "", "", "", "", "89.6", "97.8", "", "", "", "", "96.2"]} +{"pcdb_id": 17751, "brand_name": "Glow-worm", "model_name": "HOME 18s", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 18.3, "final_year_of_manufacture": 2016, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017751", "000207", "0", "2017/Jun/15 09:29", "Glow-worm", "Glow-worm", "HOME 18s", "", "41-019-29", "2015", "2016", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18.3", "18.3", "", "", "88.6", "79.6", "", "58.2", "", "2", "", "", "102", "1", "2", "105", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0085", "", "", "", "", "", "", "", "", "89.6", "97.8", "", "", "", "", "96.2"]} +{"pcdb_id": 17752, "brand_name": "Glow-worm", "model_name": "HOME 25s", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 25.4, "final_year_of_manufacture": 2016, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017752", "000207", "0", "2017/Jun/15 09:30", "Glow-worm", "Glow-worm", "HOME 25s", "", "41-019-30", "2015", "2016", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "25.4", "25.4", "", "", "88.6", "79.6", "", "58.2", "", "2", "", "", "102", "1", "2", "110", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0085", "", "", "", "", "", "", "", "", "89.6", "97.8", "", "", "", "", "96.2"]} +{"pcdb_id": 17753, "brand_name": "Glow-worm", "model_name": "SUSTAIN 15s", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 15.2, "final_year_of_manufacture": 2016, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017753", "000207", "0", "2017/Jun/15 09:22", "Glow-worm", "Glow-worm", "SUSTAIN 15s", "", "41-019-37", "2015", "2016", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "15.2", "15.2", "", "", "88.6", "79.6", "", "58.2", "", "2", "", "", "102", "1", "2", "65", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0085", "", "", "", "", "", "", "", "", "89.6", "97.8", "", "", "", "", "96.2"]} +{"pcdb_id": 17754, "brand_name": "Glow-worm", "model_name": "SUSTAIN 18s", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 18.3, "final_year_of_manufacture": 2016, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017754", "000207", "0", "2017/Jun/15 09:22", "Glow-worm", "Glow-worm", "SUSTAIN 18s", "", "41-019-38", "2015", "2016", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18.3", "18.3", "", "", "88.6", "79.6", "", "58.2", "", "2", "", "", "102", "1", "2", "65", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0085", "", "", "", "", "", "", "", "", "89.6", "97.8", "", "", "", "", "96.2"]} +{"pcdb_id": 17755, "brand_name": "Glow-worm", "model_name": "SUSTAIN 12s", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 12.3, "final_year_of_manufacture": 2016, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017755", "000207", "0", "2017/Jun/15 09:20", "Glow-worm", "Glow-worm", "SUSTAIN 12s", "", "41-019-36", "2015", "2016", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "12.3", "12.3", "", "", "88.6", "79.6", "", "58.2", "", "2", "", "", "102", "1", "2", "65", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0085", "", "", "", "", "", "", "", "", "89.6", "97.8", "", "", "", "", "96.2"]} +{"pcdb_id": 17756, "brand_name": "Glow-worm", "model_name": "Easicom 2 24c", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 62.5, "output_kw_max": 20.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017756", "000207", "0", "2015/Sep/21 14:23", "Glow-worm", "Glow-worm", "Easicom 2 24c", "", "47-019-22", "2015", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "20.3", "20.3", "", "", "88.6", "80.0", "", "62.5", "", "2", "", "", "104", "1", "2", "27", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "", "0085", "", "", "", "", "", "", "", "", "89.6", "97.8", "", "", "", "", "96.2"]} +{"pcdb_id": 17757, "brand_name": "Glow-worm", "model_name": "Easicom 2 28c", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 62.5, "output_kw_max": 25.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017757", "000207", "0", "2015/Sep/21 14:23", "Glow-worm", "Glow-worm", "Easicom 2 28c", "", "47-019-23", "2015", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "25.4", "25.4", "", "", "88.6", "80.0", "", "62.5", "", "2", "", "", "104", "1", "2", "29", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "", "0085", "", "", "", "", "", "", "", "", "89.6", "97.8", "", "", "", "", "96.2"]} +{"pcdb_id": 17758, "brand_name": "Glow-worm", "model_name": "Essential 24c", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 62.5, "output_kw_max": 20.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017758", "000207", "0", "2015/Sep/21 14:23", "Glow-worm", "Glow-worm", "Essential 24c", "", "47-019-27", "2015", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "20.3", "20.3", "", "", "88.6", "80.0", "", "62.5", "", "2", "", "", "104", "1", "2", "27", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "", "0085", "", "", "", "", "", "", "", "", "89.6", "97.8", "", "", "", "", "96.2"]} +{"pcdb_id": 17759, "brand_name": "Glow-worm", "model_name": "Essential 28c", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 62.5, "output_kw_max": 24.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017759", "000207", "0", "2015/Sep/21 14:23", "Glow-worm", "Glow-worm", "Essential 28c", "", "47-019-28", "2015", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.6", "24.6", "", "", "88.6", "80.0", "", "62.5", "", "2", "", "", "104", "1", "2", "29", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "", "0085", "", "", "", "", "", "", "", "", "89.6", "97.8", "", "", "", "", "96.2"]} +{"pcdb_id": 17760, "brand_name": "Glow-worm", "model_name": "Energy 25c", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 62.5, "output_kw_max": 18.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017760", "000207", "0", "2015/Sep/21 14:23", "Glow-worm", "Glow-worm", "Energy 25c", "", "47-019-24", "2015", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "18.3", "18.3", "", "", "88.6", "80.0", "", "62.5", "", "2", "", "", "104", "1", "2", "25", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "", "0085", "", "", "", "", "", "", "", "", "89.6", "97.8", "", "", "", "", "96.2"]} +{"pcdb_id": 17761, "brand_name": "Glow-worm", "model_name": "Energy 30c", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 62.5, "output_kw_max": 25.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017761", "000207", "0", "2015/Sep/21 14:23", "Glow-worm", "Glow-worm", "Energy 30c", "", "47-019-25", "2015", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "25.4", "25.4", "", "", "88.6", "80.0", "", "62.5", "", "2", "", "", "104", "1", "2", "75", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "", "0085", "", "", "", "", "", "", "", "", "89.6", "97.8", "", "", "", "", "96.2"]} +{"pcdb_id": 17762, "brand_name": "Glow-worm", "model_name": "Energy 35c", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 62.5, "output_kw_max": 25.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017762", "000207", "0", "2015/Sep/21 14:23", "Glow-worm", "Glow-worm", "Energy 35c", "", "47-019-26", "2015", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "25.6", "25.6", "", "", "88.6", "80.0", "", "62.5", "", "2", "", "", "104", "1", "2", "60", "3", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "", "0085", "", "", "", "", "", "", "", "", "89.6", "97.8", "", "", "", "", "96.2"]} +{"pcdb_id": 17763, "brand_name": "Glow-worm", "model_name": "Energy 35 Store", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 86.8, "comparative_hot_water_efficiency_pct": 59.2, "output_kw_max": 30.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0009, "loss_factor_f1_kwh_per_day": 2.70975, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017763", "000207", "0", "2022/May/10 10:35", "Glow-worm", "Glow-worm", "Energy 35 Store", "", "47-019-37", "2015", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "30", "30", "", "", "88.4", "86.8", "", "59.2", "", "2", "", "", "106", "1", "2", "43", "5", "2", "", "", "40", "0", "7", "2", "60", "", "1", "8.89", "0.263", "0.0009", "2.70975", "", "", "", "", "", "", "", "", "0085", "", "", "", "", "", "", "", "", "88.2", "97.8", "", "", "", "", "96.0"]} +{"pcdb_id": 17765, "brand_name": "Glow-worm", "model_name": "HOME 12r", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 12.3, "final_year_of_manufacture": 2016, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017765", "000207", "0", "2015/Sep/21 14:23", "Glow-worm", "Glow-worm", "HOME 12r", "", "41-019-31", "2015", "2016", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "12.3", "12.3", "", "", "88.6", "79.6", "", "58.2", "", "2", "", "", "102", "1", "2", "65", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0085", "", "", "", "", "", "", "", "", "89.6", "97.8", "", "", "", "", "96.2"]} +{"pcdb_id": 17766, "brand_name": "Glow-worm", "model_name": "HOME 15r", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 15.2, "final_year_of_manufacture": 2016, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017766", "000207", "0", "2017/Jun/15 09:32", "Glow-worm", "Glow-worm", "HOME 15r", "", "41-019-32", "2015", "2016", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "15.2", "15.2", "", "", "88.6", "79.6", "", "58.2", "", "2", "", "", "102", "1", "2", "65", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0085", "", "", "", "", "", "", "", "", "89.6", "97.8", "", "", "", "", "96.2"]} +{"pcdb_id": 17767, "brand_name": "Glow-worm", "model_name": "HOME 18r", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 18.3, "final_year_of_manufacture": 2016, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017767", "000207", "0", "2017/Jun/15 09:32", "Glow-worm", "Glow-worm", "HOME 18r", "", "41-019-33", "2015", "2016", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18.3", "18.3", "", "", "88.6", "79.6", "", "58.2", "", "2", "", "", "102", "1", "2", "66", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0085", "", "", "", "", "", "", "", "", "89.6", "97.8", "", "", "", "", "96.2"]} +{"pcdb_id": 17768, "brand_name": "Glow-worm", "model_name": "HOME 25r", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 25.4, "final_year_of_manufacture": 2016, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017768", "000207", "0", "2017/Jun/15 09:34", "Glow-worm", "Glow-worm", "HOME 25r", "", "41-019-34", "2015", "2016", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "25.4", "25.4", "", "", "88.6", "79.6", "", "58.2", "", "2", "", "", "102", "1", "2", "75", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0085", "", "", "", "", "", "", "", "", "89.6", "97.8", "", "", "", "", "96.2"]} +{"pcdb_id": 17770, "brand_name": "Glow-worm", "model_name": "SUSTAIN 12r", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 12.3, "final_year_of_manufacture": 2016, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017770", "000207", "0", "2017/Jun/15 09:23", "Glow-worm", "Glow-worm", "SUSTAIN 12r", "", "41-019-39", "2015", "2016", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "12.3", "12.3", "", "", "88.6", "79.6", "", "58.2", "", "2", "", "", "102", "1", "2", "65", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0085", "", "", "", "", "", "", "", "", "89.6", "97.8", "", "", "", "", "96.2"]} +{"pcdb_id": 17771, "brand_name": "Glow-worm", "model_name": "SUSTAIN 15r", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 15.2, "final_year_of_manufacture": 2016, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017771", "000207", "0", "2017/Jun/15 09:24", "Glow-worm", "Glow-worm", "SUSTAIN 15r", "", "41-019-40", "2015", "2016", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "15.2", "15.2", "", "", "88.6", "79.6", "", "58.2", "", "2", "", "", "102", "1", "2", "65", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0085", "", "", "", "", "", "", "", "", "89.6", "97.8", "", "", "", "", "96.2"]} +{"pcdb_id": 17772, "brand_name": "Glow-worm", "model_name": "SUSTAIN 18r", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 18.3, "final_year_of_manufacture": 2016, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017772", "000207", "0", "2017/Jun/15 09:25", "Glow-worm", "Glow-worm", "SUSTAIN 18r", "", "41-019-41", "2015", "2016", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18.3", "18.3", "", "", "88.6", "79.6", "", "58.2", "", "2", "", "", "102", "1", "2", "66", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0085", "", "", "", "", "", "", "", "", "89.6", "97.8", "", "", "", "", "96.2"]} +{"pcdb_id": 17773, "brand_name": "Glow-worm", "model_name": "HOME 30r", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 30.5, "final_year_of_manufacture": 2016, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017773", "000207", "0", "2017/Jun/15 09:35", "Glow-worm", "Glow-worm", "HOME 30r", "", "41-019-35", "2015", "2016", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "30.5", "30.5", "", "", "88.5", "79.5", "", "58.1", "", "2", "", "", "102", "1", "2", "60", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0085", "", "", "", "", "", "", "", "", "89.0", "97.8", "", "", "", "", "96.1"]} +{"pcdb_id": 17774, "brand_name": "Glow-worm", "model_name": "ULTIMATE 2 25s", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 25.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017774", "000207", "0", "2015/Sep/21 14:23", "Glow-worm", "Glow-worm", "ULTIMATE 2 25s", "", "47-019-42", "2015", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "25.4", "25.4", "", "", "88.6", "79.6", "", "58.2", "", "2", "", "", "102", "1", "2", "75", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0085", "", "", "", "", "", "", "", "", "89.6", "97.8", "", "", "", "", "96.2"]} +{"pcdb_id": 17775, "brand_name": "Glow-worm", "model_name": "ULTIMATE 2 30C", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 62.5, "output_kw_max": 25.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017775", "000207", "0", "2015/Sep/21 14:23", "Glow-worm", "Glow-worm", "ULTIMATE 2 30C", "", "47-019-35", "2015", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "25.4", "25.4", "", "", "88.6", "80.0", "", "62.5", "", "2", "", "", "104", "1", "2", "110", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "", "0085", "", "", "", "", "", "", "", "", "89.6", "97.8", "", "", "", "", "96.2"]} +{"pcdb_id": 17776, "brand_name": "Glow-worm", "model_name": "ULTIMATE 2 35c", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 62.5, "output_kw_max": 30.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017776", "000207", "0", "2015/Sep/21 14:23", "Glow-worm", "Glow-worm", "ULTIMATE 2 35c", "", "47-019-36", "2015", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "30.4", "30.4", "", "", "88.6", "80.0", "", "62.5", "", "2", "", "", "104", "1", "2", "110", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "", "0085", "", "", "", "", "", "", "", "", "89.6", "97.8", "", "", "", "", "96.2"]} +{"pcdb_id": 17777, "brand_name": "Glow-worm", "model_name": "ENERGY 18r", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 18.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017777", "000207", "0", "2015/Sep/21 14:23", "Glow-worm", "Glow-worm", "ENERGY 18r", "", "41-019-23", "2015", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18.3", "18.3", "", "", "88.6", "79.6", "", "58.2", "", "2", "", "", "102", "1", "2", "66", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0085", "", "", "", "", "", "", "", "", "89.6", "97.8", "", "", "", "", "96.2"]} +{"pcdb_id": 17778, "brand_name": "Glow-worm", "model_name": "ENERGY 25r", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 25.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017778", "000207", "0", "2015/Aug/21 14:21", "Glow-worm", "Glow-worm", "ENERGY 25r", "", "41-019-24", "2015", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "25.4", "25.4", "", "", "88.6", "79.6", "", "58.2", "", "2", "", "", "102", "1", "2", "75", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.6", "97.8", "", "", "", "", "96.2"]} +{"pcdb_id": 17779, "brand_name": "Glow-worm", "model_name": "ENERGY 30r", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 30.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017779", "000207", "0", "2015/Sep/21 14:23", "Glow-worm", "Glow-worm", "ENERGY 30r", "", "41-019-25", "2015", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "30.5", "30.5", "", "", "88.5", "79.5", "", "58.1", "", "2", "", "", "102", "1", "2", "60", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0085", "", "", "", "", "", "", "", "", "89.0", "97.8", "", "", "", "", "96.1"]} +{"pcdb_id": 17781, "brand_name": "Glow-worm", "model_name": "ENERGY 12s", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 12.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017781", "000207", "0", "2015/Sep/21 14:23", "Glow-worm", "Glow-worm", "ENERGY 12s", "", "41-019-16", "2015", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "12.3", "12.3", "", "", "88.6", "79.6", "", "58.2", "", "2", "", "", "102", "1", "2", "65", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0085", "", "", "", "", "", "", "", "", "89.6", "97.8", "", "", "", "", "96.2"]} +{"pcdb_id": 17782, "brand_name": "Glow-worm", "model_name": "ENERGY 15s", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 15.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017782", "000207", "0", "2015/Sep/21 14:23", "Glow-worm", "Glow-worm", "ENERGY 15s", "", "41-019-17", "2015", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "15.2", "15.2", "", "", "88.6", "79.6", "", "58.2", "", "2", "", "", "102", "1", "2", "75", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0085", "", "", "", "", "", "", "", "", "89.6", "97.8", "", "", "", "", "96.2"]} +{"pcdb_id": 17783, "brand_name": "Glow-worm", "model_name": "ENERGY 18s", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 18.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017783", "000207", "0", "2015/Sep/21 14:23", "Glow-worm", "Glow-worm", "ENERGY 18s", "", "41-019-18", "2015", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18.3", "18.3", "", "", "88.6", "79.6", "", "58.2", "", "2", "", "", "102", "1", "2", "66", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0085", "", "", "", "", "", "", "", "", "89.6", "97.8", "", "", "", "", "96.2"]} +{"pcdb_id": 17784, "brand_name": "Glow-worm", "model_name": "ENERGY 25s", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 25.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017784", "000207", "0", "2015/Sep/21 14:23", "Glow-worm", "Glow-worm", "ENERGY 25s", "", "41-019-19", "2015", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "25.4", "25.4", "", "", "88.6", "79.6", "", "58.2", "", "2", "", "", "102", "1", "2", "75", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0085", "", "", "", "", "", "", "", "", "89.6", "97.8", "", "", "", "", "96.2"]} +{"pcdb_id": 17785, "brand_name": "Glow-worm", "model_name": "ENERGY 30s", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 30.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017785", "000207", "0", "2015/Sep/21 14:23", "Glow-worm", "Glow-worm", "ENERGY 30s", "", "41-019-20", "2015", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "30.5", "30.5", "", "", "88.5", "79.5", "", "58.1", "", "2", "", "", "102", "1", "2", "60", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0085", "", "", "", "", "", "", "", "", "89.0", "97.8", "", "", "", "", "96.1"]} +{"pcdb_id": 17789, "brand_name": "Glow-worm", "model_name": "ENERGY 12r", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 12.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017789", "000207", "0", "2015/Sep/21 14:23", "Glow-worm", "Glow-worm", "ENERGY 12r", "", "41-019-21", "2015", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "12.3", "12.3", "", "", "88.6", "79.6", "", "58.2", "", "2", "", "", "102", "1", "2", "65", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0085", "", "", "", "", "", "", "", "", "89.6", "97.8", "", "", "", "", "96.2"]} +{"pcdb_id": 17790, "brand_name": "Glow-worm", "model_name": "ENERGY 15r", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 15.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017790", "000207", "0", "2015/Sep/21 14:23", "Glow-worm", "Glow-worm", "ENERGY 15r", "", "41-019-22", "2015", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "15.2", "15.2", "", "", "88.6", "79.6", "", "58.2", "", "2", "", "", "102", "1", "2", "65", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0085", "", "", "", "", "", "", "", "", "89.6", "97.8", "", "", "", "", "96.2"]} +{"pcdb_id": 17791, "brand_name": "Glow-worm", "model_name": "Ultimate 2 25r", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 25.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017791", "000207", "0", "2015/Aug/21 14:08", "Glow-worm", "Glow-worm", "Ultimate 2 25r", "", "47-019-43", "2015", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "25.4", "25.4", "", "", "88.6", "79.6", "", "58.2", "", "2", "", "", "102", "1", "2", "75", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.6", "97.8", "", "", "", "", "96.2"]} +{"pcdb_id": 17795, "brand_name": "Heatline", "model_name": "CAPRIZ 2 24c", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 62.5, "output_kw_max": 18.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017795", "000031", "0", "2021/Feb/18 14:30", "Vaillant", "Heatline", "CAPRIZ 2 24c", "", "47-157-27", "2015", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "18.3", "18.3", "", "", "88.6", "80.0", "", "62.5", "", "2", "", "", "104", "1", "2", "105", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "", "00010005", "", "", "", "", "", "", "", "", "89.6", "97.8", "", "", "", "", "96.2"]} +{"pcdb_id": 17796, "brand_name": "Heatline", "model_name": "CAPRIZ 2 28c", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 62.5, "output_kw_max": 24.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017796", "000031", "0", "2021/Feb/18 14:38", "Vaillant", "Heatline", "CAPRIZ 2 28c", "", "47-157-28", "2015", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.6", "24.6", "", "", "88.6", "80.0", "", "62.5", "", "2", "", "", "104", "1", "2", "110", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "", "00010005", "", "", "", "", "", "", "", "", "89.6", "97.8", "", "", "", "", "96.2"]} +{"pcdb_id": 17797, "brand_name": "Heatline", "model_name": "MONZA 2 24c", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 62.5, "output_kw_max": 18.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017797", "000031", "0", "2015/Aug/10 11:27", "Vaillant", "Heatline", "MONZA 2 24c", "", "47-157-29", "2015", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "18.3", "18.3", "", "", "88.6", "80.0", "", "62.5", "", "2", "", "", "104", "1", "2", "25", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "", "0005", "", "", "", "", "", "", "", "", "89.6", "97.8", "", "", "", "", "96.2"]} +{"pcdb_id": 17798, "brand_name": "Heatline", "model_name": "MONZA 2 28c", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 62.5, "output_kw_max": 24.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017798", "000031", "0", "2015/Aug/10 11:29", "Vaillant", "Heatline", "MONZA 2 28c", "", "47-157-30", "2015", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.6", "24.6", "", "", "88.6", "80.0", "", "62.5", "", "2", "", "", "104", "1", "2", "29", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "1", "", "0005", "", "", "", "", "", "", "", "", "89.6", "97.8", "", "", "", "", "96.2"]} +{"pcdb_id": 17799, "brand_name": "Potterton", "model_name": "Gold 15 Heat ErP", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 15.24, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017799", "000005", "0", "2015/Aug/17 12:22", "Baxi Heating UK", "Potterton", "Gold 15 Heat ErP", "", "GC No. 41-592-51", "2006", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "15.24", "15.24", "", "", "88.3", "79.3", "", "57.9", "", "2", "", "", "102", "1", "2", "80", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.3", "96.5", "", "", "", "", "95.3"]} +{"pcdb_id": 17800, "brand_name": "Potterton", "model_name": "Gold 18 Heat ErP", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 17.81, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017800", "000005", "0", "2015/Aug/17 12:22", "Baxi Heating UK", "Potterton", "Gold 18 Heat ErP", "", "GC No. 41-592-52", "2006", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "17.81", "17.81", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "80", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "96.8", "", "", "", "", "95.2"]} +{"pcdb_id": 17801, "brand_name": "Potterton", "model_name": "Gold 24 Heat ErP", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 22.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017801", "000005", "0", "2015/Aug/17 12:23", "Baxi Heating UK", "Potterton", "Gold 24 Heat ErP", "", "GC No.41-592-53", "2006", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "22", "22", "", "", "88.1", "79.1", "", "57.8", "", "2", "", "", "102", "1", "2", "80", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.5", "96.5", "", "", "", "", "95.2"]} +{"pcdb_id": 17802, "brand_name": "Potterton", "model_name": "Promax SL 12 Heat ErP", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 11.82, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017802", "000005", "0", "2015/Aug/17 12:24", "Baxi Heating UK", "Potterton", "Promax SL 12 Heat ErP", "", "GC No. 41-592-34", "2006", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "11.82", "11.82", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "80", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.6", "96.5", "", "", "", "", "95.0"]} +{"pcdb_id": 17803, "brand_name": "Potterton", "model_name": "Promax SL 15 Heat ErP", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 15.24, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017803", "000005", "0", "2015/Aug/17 12:25", "Baxi Heating UK", "Potterton", "Promax SL 15 Heat ErP", "", "GC No. 41-592-35", "2006", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "15.24", "15.24", "", "", "88.3", "79.3", "", "57.9", "", "2", "", "", "102", "1", "2", "80", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.3", "96.5", "", "", "", "", "95.3"]} +{"pcdb_id": 17804, "brand_name": "Potterton", "model_name": "Promax SL 18 Heat ErP", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 17.81, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017804", "000005", "0", "2015/Aug/17 12:25", "Baxi Heating UK", "Potterton", "Promax SL 18 Heat ErP", "", "GC No. 41-592-36", "2006", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "17.81", "17.81", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "80", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "96.8", "", "", "", "", "95.2"]} +{"pcdb_id": 17805, "brand_name": "Potterton", "model_name": "Promax SL 24 Heat ErP", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 22.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017805", "000005", "0", "2015/Aug/17 12:25", "Baxi Heating UK", "Potterton", "Promax SL 24 Heat ErP", "", "GC No. 41-592-37", "2006", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "22", "22", "", "", "88.1", "79.1", "", "57.8", "", "2", "", "", "102", "1", "2", "80", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.5", "96.5", "", "", "", "", "95.2"]} +{"pcdb_id": 17806, "brand_name": "Potterton", "model_name": "Promax SL 30 Heat ErP", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 30.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017806", "000005", "0", "2015/Aug/17 12:26", "Baxi Heating UK", "Potterton", "Promax SL 30 Heat ErP", "", "GC No. 41-592-38", "2006", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "30.2", "30.2", "", "", "88.1", "79.1", "", "57.8", "", "2", "", "", "102", "1", "2", "80", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.4", "96.4", "", "", "", "", "95.1"]} +{"pcdb_id": 17807, "brand_name": "Main", "model_name": "12 Heat ErP", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 11.8, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017807", "000005", "0", "2015/Aug/17 11:15", "Baxi Heating UK", "Main", "12 Heat ErP", "", "GC No. 41-467-23", "2006", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "11.8", "11.8", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "80", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.6", "96.5", "", "", "", "", "95.0"]} +{"pcdb_id": 17808, "brand_name": "Main", "model_name": "15 Heat ErP", "model_qualifier": "", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 15.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017808", "000005", "0", "2015/Aug/17 11:16", "Baxi Heating UK", "Main", "15 Heat ErP", "", "GC No. 41-467-24", "2006", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "15.2", "15.2", "", "", "88.7", "79.7", "", "58.2", "", "2", "", "", "102", "1", "2", "80", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.3", "97.7", "", "", "", "", "96.3"]} +{"pcdb_id": 17809, "brand_name": "Main", "model_name": "18 Heat ErP", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 17.8, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017809", "000005", "0", "2015/Aug/17 11:02", "Baxi Heating UK", "Main", "18 Heat ErP", "", "GC No. 41-467-25", "2006", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "17.8", "17.8", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "80", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "96.8", "", "", "", "", "95.2"]} +{"pcdb_id": 17810, "brand_name": "Main", "model_name": "24 Heat ErP", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 22.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017810", "000005", "0", "2015/Aug/17 11:03", "Baxi Heating UK", "Main", "24 Heat ErP", "", "GC No. 41-467-26", "2006", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "22", "22", "", "", "88.1", "79.1", "", "57.8", "", "2", "", "", "102", "1", "2", "80", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.5", "96.5", "", "", "", "", "95.2"]} +{"pcdb_id": 17811, "brand_name": "Main", "model_name": "30 Heat ErP", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 30.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017811", "000005", "0", "2015/Aug/17 11:16", "Baxi Heating UK", "Main", "30 Heat ErP", "", "GC No.41-467-27", "2006", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "30.2", "30.2", "", "", "88.1", "79.1", "", "57.8", "", "2", "", "", "102", "1", "2", "80", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.4", "96.4", "", "", "", "", "95.1"]} +{"pcdb_id": 17812, "brand_name": "Vaillant", "model_name": "ecoTEC plus 835 H combi A", "model_qualifier": "VUW GB 356/5-5", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 86.9, "comparative_hot_water_efficiency_pct": 71.7, "output_kw_max": 30.4, "final_year_of_manufacture": 2017, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0013, "loss_factor_f1_kwh_per_day": 1.23356, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017812", "000031", "0", "2019/Mar/04 11:03", "Vaillant Group UK", "Vaillant", "ecoTEC plus 835 H combi A", "VUW GB 356/5-5", "47-044-53", "2015", "2017", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "30.4", "30.4", "", "", "88.7", "86.9", "", "71.7", "", "2", "", "", "104", "1", "2", "90", "2", "0", "", "", "", "0", "", "", "", "", "1", "7.3444", "0.072", "0.0013", "1.23356", "", "", "", "", "", "1", "1", "", "0045", "", "", "", "", "", "", "", "", "88.7", "98.2", "", "", "", "", "96.4"]} +{"pcdb_id": 17813, "brand_name": "Main", "model_name": "Eco Elite 24 System ErP", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 25.9, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017813", "000005", "0", "2015/Aug/17 11:16", "Baxi Heating UK", "Main", "Eco Elite 24 System ErP", "", "GC No. 41-467-28", "2012", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "25.9", "25.9", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "105", "3.5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.7", "97.0", "", "", "", "", "95.7"]} +{"pcdb_id": 17814, "brand_name": "Main", "model_name": "Eco Elite 28 System ErP", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 28.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017814", "000005", "0", "2015/Aug/17 11:03", "Baxi Heating UK", "Main", "Eco Elite 28 System ErP", "", "GC No. 41-467-29", "2012", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "28.6", "28.6", "", "", "88.1", "79.1", "", "57.8", "", "2", "", "", "102", "1", "2", "105", "3.5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "97.0", "", "", "", "", "95.3"]} +{"pcdb_id": 17815, "brand_name": "Main", "model_name": "Eco Elite 25 Combi ErP", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 56.1, "output_kw_max": 25.9, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017815", "000005", "0", "2015/Sep/21 14:23", "Baxi Heating UK", "Main", "Eco Elite 25 Combi ErP", "", "GC No. 47-467-12", "2012", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "25.9", "25.9", "", "", "88.4", "79.8", "", "56.1", "", "2", "", "", "104", "1", "2", "105", "3.5", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "89.7", "97.0", "", "", "", "", "95.7"]} +{"pcdb_id": 17816, "brand_name": "Main", "model_name": "Eco Elite 30 Combi ErP", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 55.9, "output_kw_max": 28.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017816", "000005", "0", "2015/Sep/21 14:23", "Baxi Heating UK", "Main", "Eco Elite 30 Combi ErP", "", "GC No. 47-467-13", "2012", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28.6", "28.6", "", "", "88.1", "79.5", "", "55.9", "", "2", "", "", "104", "1", "2", "105", "3.5", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "88.0", "97.0", "", "", "", "", "95.3"]} +{"pcdb_id": 17817, "brand_name": "Potterton", "model_name": "Promax 24 Store ErP", "model_qualifier": "90i Cylinder Assembly", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 52.3, "output_kw_max": 24.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017817", "000005", "0", "2024/Jan/31 10:17", "Baxi Heating UK", "Potterton", "Promax 24 Store ErP", "90i Cylinder Assembly", "GC No.41-592-47", "2006", "current", "1", "1", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "87.9", "80.8", "", "52.3", "", "2", "", "", "106", "1", "2", "126", "3", "2", "2", "", "90", "0", "45", "2", "60", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.2", "96.9", "", "", "", "", "95.0"]} +{"pcdb_id": 17818, "brand_name": "Potterton", "model_name": "Promax 24 Store ErP", "model_qualifier": "115i Cylinder Assembly", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 50.4, "output_kw_max": 24.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017818", "000005", "0", "2024/Jan/31 10:17", "Baxi Heating UK", "Potterton", "Promax 24 Store ErP", "115i Cylinder Assembly", "GC No. 41-592-48", "2006", "current", "1", "1", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "87.9", "80.8", "", "50.4", "", "2", "", "", "106", "1", "2", "126", "3", "2", "2", "", "115", "0", "45", "2", "60", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.2", "96.9", "", "", "", "", "95.0"]} +{"pcdb_id": 17819, "brand_name": "Potterton", "model_name": "Promax 24 Store ErP", "model_qualifier": "150i Cylinder Assembly", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 80.9, "comparative_hot_water_efficiency_pct": 47.0, "output_kw_max": 24.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017819", "000005", "0", "2024/Jan/31 10:17", "Baxi Heating UK", "Potterton", "Promax 24 Store ErP", "150i Cylinder Assembly", "GC No.41-592-49", "2006", "current", "1", "1", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "87.9", "80.9", "", "47.0", "", "2", "", "", "106", "1", "2", "126", "3", "2", "2", "", "150", "0", "45", "2", "60", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.2", "96.9", "", "", "", "", "95.0"]} +{"pcdb_id": 17821, "brand_name": "Vaillant", "model_name": "ecoTEC plus 415", "model_qualifier": "VU 156/6-5", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 15.2, "final_year_of_manufacture": 2017, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017821", "000031", "0", "2019/Mar/04 10:03", "Vaillant", "Vaillant", "ecoTEC plus 415", "VU 156/6-5", "41-044-72", "2015", "2017", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "15.2", "15.2", "", "", "88.6", "79.6", "", "58.2", "", "2", "", "", "102", "1", "2", "65", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0045", "", "", "", "", "", "", "", "", "89.6", "97.8", "", "", "", "", "96.2"]} +{"pcdb_id": 17822, "brand_name": "Vaillant", "model_name": "ecoTEC plus 412", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 12.2, "final_year_of_manufacture": 2017, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017822", "000031", "0", "2019/Mar/04 10:04", "Vaillant", "Vaillant", "ecoTEC plus 412", "", "41-044-71", "2015", "2017", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "12.2", "12.2", "", "", "88.6", "79.6", "", "58.2", "", "2", "", "", "102", "1", "2", "65", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0045", "", "", "", "", "", "", "", "", "89.6", "97.8", "", "", "", "", "96.2"]} +{"pcdb_id": 17823, "brand_name": "Vaillant", "model_name": "ecoTEC plus 418", "model_qualifier": "VU 186/6-5", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 18.3, "final_year_of_manufacture": 2017, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017823", "000031", "0", "2019/Mar/04 10:06", "Vaillant", "Vaillant", "ecoTEC plus 418", "VU 186/6-5", "41-044-73", "2015", "2017", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18.3", "18.3", "", "", "88.6", "79.6", "", "58.2", "", "2", "", "", "102", "1", "2", "66", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0045", "", "", "", "", "", "", "", "", "89.6", "97.8", "", "", "", "", "96.2"]} +{"pcdb_id": 17824, "brand_name": "Vaillant", "model_name": "ecoTEC plus 424", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 24.6, "final_year_of_manufacture": 2019, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017824", "000031", "0", "2019/Mar/04 10:06", "Vaillant", "Vaillant", "ecoTEC plus 424", "", "41-044-74", "2015", "2019", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24.6", "24.6", "", "", "88.6", "79.6", "", "58.2", "", "2", "", "", "102", "1", "2", "75", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0045", "", "", "", "", "", "", "", "", "89.6", "97.8", "", "", "", "", "96.2"]} +{"pcdb_id": 17825, "brand_name": "Vaillant", "model_name": "ecoTEC plus 430", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 30.2, "final_year_of_manufacture": 2017, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017825", "000031", "0", "2019/Mar/04 10:08", "Vaillant", "Vaillant", "ecoTEC plus 430", "", "41-044-75", "2015", "2017", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "30.2", "30.2", "", "", "88.5", "79.5", "", "58.1", "", "2", "", "", "102", "1", "2", "60", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0045", "", "", "", "", "", "", "", "", "89.0", "97.8", "", "", "", "", "96.1"]} +{"pcdb_id": 17826, "brand_name": "Johnson & Starley", "model_name": "Quantec HR28CP", "model_qualifier": "", "winter_efficiency_pct": 89.7, "summer_efficiency_pct": 88.6, "comparative_hot_water_efficiency_pct": 83.8, "output_kw_max": 21.1, "final_year_of_manufacture": null, "subsidiary_type": 1, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0025, "loss_factor_f1_kwh_per_day": 0.3154, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017826", "000239", "0", "2015/Dec/24 09:45", "Johnson & Starley", "Johnson & Starley", "Quantec HR28CP", "", "47-416-14", "2015", "current", "2", "2", "1", "2", "1", "", "", "2", "2", "2", "21.1", "21.1", "", "", "89.7", "88.6", "", "83.8", "", "2", "0", "", "104", "1", "2", "68", "2.17", "0", "", "", "", "0", "", "", "", "", "1", "6.422", "0.068", "0.0025", "0.3154", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "", "", "", "", "89.8", "98.3", "", "", "", "", "96.7"]} +{"pcdb_id": 17827, "brand_name": "Vaillant", "model_name": "Home Regular 12", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 12.2, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017827", "000031", "0", "2019/Mar/04 10:46", "Vaillant", "Vaillant", "Home Regular 12", "", "41-044-88", "2015", "2018", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "12.2", "12.2", "", "", "88.6", "79.6", "", "58.2", "", "2", "", "", "102", "1", "2", "65", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0045", "", "", "", "", "", "", "", "", "89.6", "97.8", "", "", "", "", "96.2"]} +{"pcdb_id": 17828, "brand_name": "Vaillant", "model_name": "Home Regular 15", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 15.2, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017828", "000031", "0", "2019/Mar/04 10:48", "Vaillant", "Vaillant", "Home Regular 15", "", "41-44-88", "2015", "2018", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "15.2", "15.2", "", "", "88.6", "79.6", "", "58.2", "", "2", "", "", "102", "1", "2", "65", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0045", "", "", "", "", "", "", "", "", "89.6", "97.8", "", "", "", "", "96.2"]} +{"pcdb_id": 17829, "brand_name": "Vaillant", "model_name": "Home Regular 18", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 18.3, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017829", "000031", "0", "2019/Mar/04 10:48", "Vaillant", "Vaillant", "Home Regular 18", "", "41-44-90", "2015", "2018", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18.3", "18.3", "", "", "88.6", "79.6", "", "58.2", "", "2", "", "", "102", "1", "2", "66", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0045", "", "", "", "", "", "", "", "", "89.6", "97.8", "", "", "", "", "96.2"]} +{"pcdb_id": 17830, "brand_name": "Vaillant", "model_name": "Home Regular 25", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 25.4, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017830", "000031", "0", "2019/Mar/04 10:48", "Vaillant", "Vaillant", "Home Regular 25", "", "41-44-92", "2015", "2018", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "25.4", "25.4", "", "", "88.6", "79.6", "", "58.2", "", "2", "", "", "102", "1", "2", "75", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0045", "", "", "", "", "", "", "", "", "89.6", "97.8", "", "", "", "", "96.2"]} +{"pcdb_id": 17831, "brand_name": "Vaillant", "model_name": "Home Regular 30", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 30.2, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017831", "000031", "0", "2019/Mar/04 10:49", "Vaillant", "Vaillant", "Home Regular 30", "", "41-44-93", "2015", "2018", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "30.2", "30.2", "", "", "88.5", "79.5", "", "58.1", "", "2", "", "", "102", "1", "2", "60", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0045", "", "", "", "", "", "", "", "", "89.0", "97.8", "", "", "", "", "96.1"]} +{"pcdb_id": 17832, "brand_name": "Vaillant", "model_name": "Home System 12", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 12.1, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017832", "000031", "0", "2019/Mar/04 10:49", "Vaillant", "Vaillant", "Home System 12", "", "41-44-94", "2015", "2018", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "12.1", "12.1", "", "", "88.6", "79.6", "", "58.2", "", "2", "", "", "102", "1", "2", "105", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0045", "", "", "", "", "", "", "", "", "89.6", "97.8", "", "", "", "", "96.2"]} +{"pcdb_id": 17833, "brand_name": "Vaillant", "model_name": "Home System 15", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 15.2, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017833", "000031", "0", "2019/Mar/04 10:49", "Vaillant", "Vaillant", "Home System 15", "", "41-44-95", "2015", "2018", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "15.2", "15.2", "", "", "88.6", "79.6", "", "58.2", "", "2", "", "", "102", "1", "2", "105", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0045", "", "", "", "", "", "", "", "", "89.6", "97.8", "", "", "", "", "96.2"]} +{"pcdb_id": 17834, "brand_name": "Vaillant", "model_name": "Home System 18", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 18.3, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017834", "000031", "0", "2019/Mar/04 10:50", "Vaillant", "Vaillant", "Home System 18", "", "41-44-96", "2015", "2018", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18.3", "18.3", "", "", "88.6", "79.6", "", "58.2", "", "2", "", "", "102", "1", "2", "105", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0045", "", "", "", "", "", "", "", "", "89.6", "97.8", "", "", "", "", "96.2"]} +{"pcdb_id": 17835, "brand_name": "Vaillant", "model_name": "Home System 25", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 25.4, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017835", "000031", "0", "2019/Mar/04 10:50", "Vaillant", "Vaillant", "Home System 25", "", "41-44-97", "2015", "2018", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "25.4", "25.4", "", "", "88.6", "79.6", "", "58.2", "", "2", "", "", "102", "1", "2", "110", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0045", "", "", "", "", "", "", "", "", "89.6", "97.8", "", "", "", "", "96.2"]} +{"pcdb_id": 17836, "brand_name": "Vaillant", "model_name": "Home Combi 25", "model_qualifier": "", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 77.0, "output_kw_max": 15.2, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0095, "loss_factor_f1_kwh_per_day": 0.71853, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017836", "000031", "0", "2019/Mar/04 10:36", "Vaillant", "Vaillant", "Home Combi 25", "", "", "2015", "2018", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "15.2", "15.2", "", "", "88.7", "87.3", "", "77.0", "", "2", "", "", "104", "1", "2", "105", "2", "0", "", "", "0", "0", "", "", "", "", "1", "6.835", "0.096", "0.0095", "0.71853", "", "", "", "", "", "1", "1", "", "0045", "", "", "", "", "", "", "", "", "89.7", "97.8", "", "", "", "", "96.2"]} +{"pcdb_id": 17837, "brand_name": "Vaillant", "model_name": "Home Combi 30", "model_qualifier": "", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 75.8, "output_kw_max": 15.2, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0115, "loss_factor_f1_kwh_per_day": 0.81337, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017837", "000031", "0", "2019/Mar/04 10:36", "Vaillant", "Vaillant", "Home Combi 30", "", "", "2015", "2018", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "15.2", "15.2", "", "", "88.7", "87.3", "", "75.8", "", "2", "", "", "104", "1", "2", "110", "2", "0", "", "", "", "0", "", "", "", "", "1", "6.945", "0.085", "0.0115", "0.81337", "", "", "", "", "", "1", "1", "", "0045", "", "", "", "", "", "", "", "", "89.7", "97.8", "", "", "", "", "96.2"]} +{"pcdb_id": 17838, "brand_name": "Vaillant", "model_name": "Home Combi 35", "model_qualifier": "", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 76.1, "output_kw_max": 15.2, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0045, "loss_factor_f1_kwh_per_day": 0.83104, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017838", "000031", "0", "2019/Mar/04 10:37", "Vaillant", "Vaillant", "Home Combi 35", "", "", "2015", "2018", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "15.2", "15.2", "", "", "88.7", "87.3", "", "76.1", "", "2", "", "", "104", "1", "2", "120", "3", "0", "", "", "", "0", "", "", "", "", "1", "6.921", "0.096", "0.0045", "0.83104", "", "", "", "", "", "1", "1", "", "0045", "", "", "", "", "", "", "", "", "89.7", "97.8", "", "", "", "", "96.2"]} +{"pcdb_id": 17839, "brand_name": "ATAG", "model_name": "iC Economiser 27", "model_qualifier": "", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 86.8, "comparative_hot_water_efficiency_pct": 83.2, "output_kw_max": 21.2, "final_year_of_manufacture": null, "subsidiary_type": 1, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0012, "loss_factor_f1_kwh_per_day": 0.24179, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017839", "000299", "0", "2018/Jan/04 15:44", "ATAG Verwarming Nederland BV", "ATAG", "iC Economiser 27", "", "47-310-27", "2015", "current", "1", "2", "1", "2", "1", "", "", "2", "3", "2", "21.2", "21.2", "", "", "89.1", "86.8", "", "83.2", "", "2", "", "", "104", "1", "2", "184", "4", "0", "", "", "", "0", "", "", "", "", "1", "6.327", "0.181", "0.0012", "0.24179", "11.529", "0.204", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "99.4", "", "", "", "", "97.3"]} +{"pcdb_id": 17840, "brand_name": "ATAG", "model_name": "iC Economiser 35", "model_qualifier": "", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 86.9, "comparative_hot_water_efficiency_pct": 78.7, "output_kw_max": 28.3, "final_year_of_manufacture": 2018, "subsidiary_type": 1, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0, "loss_factor_f1_kwh_per_day": 0.6081, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017840", "000299", "0", "2018/Apr/25 14:56", "ATAG Verwarming Nederland BV", "ATAG", "iC Economiser 35", "", "47-310-29", "2015", "2018", "1", "2", "1", "2", "1", "", "", "2", "3", "2", "28.3", "28.3", "", "", "89.1", "86.9", "", "78.7", "", "2", "", "", "104", "1", "2", "112", "5", "0", "", "", "", "0", "", "", "", "", "1", "6.693", "0.172", "0.0", "0.6081", "11.794", "0.192", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.6", "99.5", "", "", "", "", "97.4"]} +{"pcdb_id": 17841, "brand_name": "ATAG", "model_name": "iC Economiser 39", "model_qualifier": "", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 86.9, "comparative_hot_water_efficiency_pct": 78.7, "output_kw_max": 28.3, "final_year_of_manufacture": 2018, "subsidiary_type": 1, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0, "loss_factor_f1_kwh_per_day": 0.6081, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017841", "000299", "0", "2018/Apr/25 14:58", "ATAG Verwarming Nederland BV", "ATAG", "iC Economiser 39", "", "47-310-31", "2015", "2018", "1", "2", "1", "2", "1", "", "", "2", "3", "2", "28.3", "28.3", "", "", "89.1", "86.9", "", "78.7", "", "2", "", "", "104", "1", "2", "112", "4", "0", "", "", "", "0", "", "", "", "", "1", "6.693", "0.172", "0.0", "0.6081", "11.794", "0.192", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.6", "99.5", "", "", "", "", "97.4"]} +{"pcdb_id": 17842, "brand_name": "Intergas", "model_name": "Rapid 25", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 56.1, "output_kw_max": 25.1, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017842", "000256", "0", "2015/Dec/11 11:22", "Intergas Heating Ltd", "Intergas", "Rapid 25", "", "", "2015", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "25.1", "25.1", "", "", "88.4", "79.8", "", "56.1", "", "2", "", "", "104", "1", "2", "80", "1.9", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.1", "97.8", "", "", "", "", "96.0"]} +{"pcdb_id": 17843, "brand_name": "Intergas", "model_name": "Rapid 32", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 56.1, "output_kw_max": 31.9, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017843", "000256", "0", "2015/Dec/11 11:21", "Intergas Heating Ltd", "Intergas", "Rapid 32", "", "", "2015", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "31.9", "31.9", "", "", "88.3", "79.7", "", "56.1", "", "2", "", "", "104", "1", "2", "80", "1.9", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "97.6", "", "", "", "", "95.8"]} +{"pcdb_id": 17845, "brand_name": "Biasi", "model_name": "Advance Plus 16S ErP", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 15.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017845", "000208", "0", "2015/Dec/14 09:52", "Biasi (UK)", "Biasi", "Advance Plus 16S ErP", "", "41-583-27", "2015", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "15.6", "15.6", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "78", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "96.8", "", "", "", "", "95.1"]} +{"pcdb_id": 17846, "brand_name": "Biasi", "model_name": "Advance Plus 25S ErP", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 24.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017846", "000208", "0", "2015/Dec/11 09:27", "Biasi (UK)", "Biasi", "Advance Plus 25S ErP", "", "41-583-28", "2015", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24.4", "24.4", "", "", "88.1", "79.1", "", "57.7", "", "2", "", "", "102", "1", "2", "95", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "97.0", "", "", "", "", "95.3"]} +{"pcdb_id": 17847, "brand_name": "Biasi", "model_name": "Advance Plus 30S ErP", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 29.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017847", "000208", "0", "2015/Dec/11 09:27", "Biasi (UK)", "Biasi", "Advance Plus 30S ErP", "", "41-583-29", "2015", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "29.5", "29.5", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "104", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.5", "96.7", "", "", "", "", "95.1"]} +{"pcdb_id": 17848, "brand_name": "Biasi", "model_name": "Advance Plus 25C ErP", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 86.6, "comparative_hot_water_efficiency_pct": 74.1, "output_kw_max": 19.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0, "loss_factor_f1_kwh_per_day": 0.98922, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017848", "000208", "0", "2015/Dec/11 09:28", "Biasi (UK)", "Biasi", "Advance Plus 25C ErP", "", "47-583-35", "2015", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "19.5", "19.5", "", "", "88.1", "86.6", "", "74.1", "", "2", "", "", "104", "1", "2", "86", "5", "0", "", "", "", "0", "", "", "", "", "1", "7.11", "0.149", "0.0", "0.98922", "", "", "", "", "", "1", "0", "", "0005", "", "", "", "", "", "", "", "", "87.8", "97.0", "", "", "", "", "95.3"]} +{"pcdb_id": 17849, "brand_name": "Biasi", "model_name": "Advance Plus 30C ErP", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 86.8, "comparative_hot_water_efficiency_pct": 74.1, "output_kw_max": 24.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.002, "loss_factor_f1_kwh_per_day": 0.98571, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017849", "000208", "0", "2015/Dec/11 09:28", "Biasi (UK)", "Biasi", "Advance Plus 30C ErP", "", "47-583-36", "2015", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.4", "24.4", "", "", "88.0", "86.8", "", "74.1", "", "2", "", "", "104", "1", "2", "95", "5", "0", "", "", "", "0", "", "", "", "", "1", "7.104", "0.163", "0.002", "0.98571", "", "", "", "", "", "1", "0", "", "0005", "", "", "", "", "", "", "", "", "88.3", "96.7", "", "", "", "", "95.1"]} +{"pcdb_id": 17851, "brand_name": "Biasi", "model_name": "Advance Plus 35C ErP", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 86.8, "comparative_hot_water_efficiency_pct": 74.0, "output_kw_max": 29.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.002, "loss_factor_f1_kwh_per_day": 1.00577, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017851", "000208", "0", "2015/Dec/11 09:29", "Biasi (UK)", "Biasi", "Advance Plus 35C ErP", "", "47-583-37", "2015", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "29.5", "29.5", "", "", "88.0", "86.8", "", "74.0", "", "2", "", "", "104", "1", "2", "104", "5", "0", "", "", "", "0", "", "", "", "", "1", "7.12", "0.152", "0.002", "1.00577", "", "", "", "", "", "1", "0", "", "0005", "", "", "", "", "", "", "", "", "88.5", "96.7", "", "", "", "", "95.1"]} +{"pcdb_id": 17852, "brand_name": "Biasi", "model_name": "Inovia 25S ErP", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 24.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017852", "000208", "0", "2015/Dec/11 09:29", "Biasi (UK)", "Biasi", "Inovia 25S ErP", "", "41-583-30", "2015", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24.4", "24.4", "", "", "88.1", "79.1", "", "57.7", "", "2", "", "", "102", "1", "2", "95", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "97.0", "", "", "", "", "95.3"]} +{"pcdb_id": 17853, "brand_name": "Biasi", "model_name": "Inovia 25C ErP", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 86.6, "comparative_hot_water_efficiency_pct": 74.1, "output_kw_max": 19.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0, "loss_factor_f1_kwh_per_day": 0.98922, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017853", "000208", "0", "2015/Dec/11 09:30", "Biasi (UK)", "Biasi", "Inovia 25C ErP", "", "47-583-38", "2015", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "19.5", "19.5", "", "", "88.1", "86.6", "", "74.1", "", "2", "", "", "104", "1", "2", "86", "5", "0", "", "", "", "0", "", "", "", "", "1", "7.11", "0.149", "0.0", "0.98922", "", "", "", "", "", "1", "1", "", "0005", "", "", "", "", "", "", "", "", "87.8", "97.0", "", "", "", "", "95.3"]} +{"pcdb_id": 17854, "brand_name": "Biasi", "model_name": "Inovia 30C ErP", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 86.8, "comparative_hot_water_efficiency_pct": 74.1, "output_kw_max": 24.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.002, "loss_factor_f1_kwh_per_day": 0.98571, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017854", "000208", "0", "2015/Dec/11 09:30", "Biasi (UK)", "Biasi", "Inovia 30C ErP", "", "47-583-39", "2015", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.4", "24.4", "", "", "88.0", "86.8", "", "74.1", "", "2", "", "", "104", "1", "2", "95", "5", "0", "", "", "", "0", "", "", "", "", "1", "7.104", "0.163", "0.002", "0.98571", "", "", "", "", "", "1", "1", "", "0005", "", "", "", "", "", "", "", "", "88.3", "96.7", "", "", "", "", "95.1"]} +{"pcdb_id": 17855, "brand_name": "Biasi", "model_name": "Inovia 35C ErP", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 86.8, "comparative_hot_water_efficiency_pct": 74.0, "output_kw_max": 29.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.002, "loss_factor_f1_kwh_per_day": 1.00577, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017855", "000208", "0", "2015/Dec/11 09:30", "Biasi (UK)", "Biasi", "Inovia 35C ErP", "", "47-583-40", "2015", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "29.5", "29.5", "", "", "88.0", "86.8", "", "74.0", "", "2", "", "", "104", "1", "2", "104", "5", "0", "", "", "", "0", "", "", "", "", "1", "7.12", "0.152", "0.002", "1.00577", "", "", "", "", "", "1", "1", "", "0005", "", "", "", "", "", "", "", "", "88.5", "96.7", "", "", "", "", "95.1"]} +{"pcdb_id": 17856, "brand_name": "Biasi", "model_name": "Riva Plus HE 24C ErP", "model_qualifier": "", "winter_efficiency_pct": 87.4, "summer_efficiency_pct": 86.6, "comparative_hot_water_efficiency_pct": 67.4, "output_kw_max": 24.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.005, "loss_factor_f1_kwh_per_day": 1.63862, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017856", "000208", "0", "2015/Dec/11 09:30", "Biasi (UK)", "Biasi", "Riva Plus HE 24C ErP", "", "47-583-41", "2015", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.4", "24.4", "", "", "87.4", "86.6", "", "67.4", "", "2", "", "", "104", "1", "2", "79", "3", "0", "", "", "", "0", "", "", "", "", "1", "7.816", "0.131", "0.005", "1.63862", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "95.4", "", "", "", "", "94.0"]} +{"pcdb_id": 17857, "brand_name": "Biasi", "model_name": "Riva Plus HE 28C ErP", "model_qualifier": "", "winter_efficiency_pct": 87.4, "summer_efficiency_pct": 86.7, "comparative_hot_water_efficiency_pct": 68.0, "output_kw_max": 28.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.013, "loss_factor_f1_kwh_per_day": 1.53602, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017857", "000208", "0", "2015/Dec/11 09:31", "Biasi (UK)", "Biasi", "Riva Plus HE 28C ErP", "", "47-583-42", "2015", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28.3", "28.3", "", "", "87.4", "86.7", "", "68.0", "", "2", "", "", "104", "1", "2", "90", "3", "0", "", "", "", "0", "", "", "", "", "1", "7.75", "0.137", "0.013", "1.53602", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "95.2", "", "", "", "", "93.9"]} +{"pcdb_id": 17858, "brand_name": "Biasi", "model_name": "Riva Plus HE 24S ErP", "model_qualifier": "", "winter_efficiency_pct": 87.4, "summer_efficiency_pct": 78.4, "comparative_hot_water_efficiency_pct": 57.3, "output_kw_max": 24.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017858", "000208", "0", "2015/Dec/11 09:31", "Biasi (UK)", "Biasi", "Riva Plus HE 24S ErP", "", "41-583-31", "2015", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24.4", "24.4", "", "", "87.4", "78.4", "", "57.3", "", "2", "", "", "102", "1", "2", "79", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "95.4", "", "", "", "", "94.0"]} +{"pcdb_id": 17859, "brand_name": "Biasi", "model_name": "Riva Plus HE 28S ErP", "model_qualifier": "", "winter_efficiency_pct": 87.4, "summer_efficiency_pct": 78.4, "comparative_hot_water_efficiency_pct": 57.3, "output_kw_max": 28.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017859", "000208", "0", "2015/Dec/11 09:31", "Biasi (UK)", "Biasi", "Riva Plus HE 28S ErP", "", "41-583-32", "2015", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "28.3", "28.3", "", "", "87.4", "78.4", "", "57.3", "", "2", "", "", "102", "1", "2", "90", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "95.2", "", "", "", "", "93.9"]} +{"pcdb_id": 17861, "brand_name": "Ideal", "model_name": "LOGIC COMBI", "model_qualifier": "ESP24", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 76.9, "output_kw_max": 24.2, "final_year_of_manufacture": 2016, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0005, "loss_factor_f1_kwh_per_day": 0.78594, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017861", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "LOGIC COMBI", "ESP24", "47-349-12", "2016", "2016", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "88.4", "87.3", "", "76.9", "", "2", "", "", "104", "1", "2", "42", "0.5", "0", "", "", "", "0", "", "", "", "", "1", "6.848", "0.096", "0.0005", "0.78594", "", "", "", "", "", "0", "", "", "0035", "", "", "", "", "", "", "", "", "89.8", "96.9", "", "", "", "", "95.6"]} +{"pcdb_id": 17862, "brand_name": "Ideal", "model_name": "LOGIC COMBI", "model_qualifier": "ESP30", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 79.4, "output_kw_max": 24.2, "final_year_of_manufacture": 2016, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0005, "loss_factor_f1_kwh_per_day": 0.58118, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017862", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "LOGIC COMBI", "ESP30", "47-349-13", "2016", "2016", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "88.4", "87.3", "", "79.4", "", "2", "", "", "104", "1", "2", "32", "5", "0", "", "", "", "0", "", "", "", "", "1", "6.632", "0.094", "0.0005", "0.58118", "", "", "", "", "", "0", "", "", "0035", "", "", "", "", "", "", "", "", "90.0", "96.9", "", "", "", "", "95.6"]} +{"pcdb_id": 17863, "brand_name": "Ideal", "model_name": "LOGIC COMBI", "model_qualifier": "ESP35", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 79.0, "output_kw_max": 24.2, "final_year_of_manufacture": 2016, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0006, "loss_factor_f1_kwh_per_day": 0.61175, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017863", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "LOGIC COMBI", "ESP35", "47-349-14", "2016", "2016", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "88.3", "87.3", "", "79.0", "", "2", "", "", "104", "1", "2", "29", "5", "0", "", "", "", "0", "", "", "", "", "1", "6.669", "0.094", "0.0006", "0.61175", "", "", "", "", "", "0", "", "", "0035", "", "", "", "", "", "", "", "", "89.8", "96.9", "", "", "", "", "95.5"]} +{"pcdb_id": 17867, "brand_name": "Sime", "model_name": "Murelle HE", "model_qualifier": "50 R ErP", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 46.8, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017867", "000213", "0", "2018/Mar/07 10:10", "Fonderie Sime S.p.A.", "Sime", "Murelle HE", "50 R ErP", "41-283-60", "2015", "2018", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "46.8", "46.8", "", "", "88.8", "79.8", "", "58.3", "", "2", "1", "", "102", "1", "2", "96", "4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.8", "98.5", "", "", "", "", "96.9"]} +{"pcdb_id": 17868, "brand_name": "Sime", "model_name": "Murelle HE", "model_qualifier": "50 R ErP", "winter_efficiency_pct": 87.8, "summer_efficiency_pct": 78.8, "comparative_hot_water_efficiency_pct": 57.6, "output_kw_max": 46.8, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017868", "000213", "0", "2018/Mar/07 09:48", "Fonderie Sime S.p.A.", "Sime", "Murelle HE", "50 R ErP", "41-283-60", "2015", "2018", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "46.8", "46.8", "", "", "87.8", "78.8", "", "57.6", "", "2", "", "", "102", "1", "2", "96", "4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "96.4", "", "", "", "", "94.8"]} +{"pcdb_id": 17869, "brand_name": "Sime", "model_name": "Murelle HE", "model_qualifier": "35 R ErP", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 33.8, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017869", "000213", "0", "2018/Mar/05 16:57", "Fonderie Sime S.p.A.", "Sime", "Murelle HE", "35 R ErP", "41-283-59", "2015", "2018", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "33.8", "33.8", "", "", "88.8", "79.8", "", "58.3", "", "2", "1", "", "102", "1", "2", "64", "4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.5", "98.5", "", "", "", "", "96.8"]} +{"pcdb_id": 17870, "brand_name": "Sime", "model_name": "Murelle HE", "model_qualifier": "35 R ErP", "winter_efficiency_pct": 87.8, "summer_efficiency_pct": 78.8, "comparative_hot_water_efficiency_pct": 57.5, "output_kw_max": 33.8, "final_year_of_manufacture": 2018, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017870", "000213", "0", "2018/Mar/05 16:57", "Fonderie Sime S.p.A.", "Sime", "Murelle HE", "35 R ErP", "41-283-59", "2015", "2018", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "33.8", "33.8", "", "", "87.8", "78.8", "", "57.5", "", "2", "", "", "102", "1", "2", "64", "4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.6", "96.4", "", "", "", "", "94.7"]} +{"pcdb_id": 17873, "brand_name": "Grant", "model_name": "VortexBlue Internal 21kW", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 80.7, "comparative_hot_water_efficiency_pct": 58.9, "output_kw_max": 21.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017873", "000048", "0", "2020/Jan/15 12:18", "Grant Engineering", "Grant", "VortexBlue Internal 21kW", "", "", "2017", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "15", "21", "", "", "88.5", "80.7", "", "58.9", "", "2", "", "", "201", "1", "1", "143", "1", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.4", "95.8", "", "", "", "", "94.9"]} +{"pcdb_id": 17874, "brand_name": "Grant", "model_name": "VortexBlue Internal 26kW", "model_qualifier": "", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 80.9, "comparative_hot_water_efficiency_pct": 59.1, "output_kw_max": 26.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017874", "000048", "0", "2020/Apr/15 08:57", "Grant Engineering", "Grant", "VortexBlue Internal 26kW", "", "", "2017", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "26", "26", "", "", "88.7", "80.9", "", "59.1", "", "2", "", "", "201", "1", "1", "147", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "92.7", "95.9", "", "", "", "", "95.2"]} +{"pcdb_id": 17875, "brand_name": "Grant", "model_name": "VortexBlue Internal Sealed System 21kW", "model_qualifier": "", "winter_efficiency_pct": 87.7, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 21.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017875", "000048", "0", "2020/Jan/15 12:19", "Grant Engineering", "Grant", "VortexBlue Internal Sealed System 21kW", "", "", "2017", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "15", "21", "", "", "87.7", "79.9", "", "58.4", "", "2", "", "", "201", "1", "1", "143", "1", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "88.5", "95.8", "", "", "", "", "94.4"]} +{"pcdb_id": 17876, "brand_name": "Grant", "model_name": "VortexBlue Internal Sealed System 26kW", "model_qualifier": "", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 80.9, "comparative_hot_water_efficiency_pct": 59.1, "output_kw_max": 26.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017876", "000048", "0", "2020/Apr/15 08:57", "Grant Engineering", "Grant", "VortexBlue Internal Sealed System 26kW", "", "", "2017", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "26", "26", "", "", "88.7", "80.9", "", "59.1", "", "2", "", "", "201", "1", "1", "147", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "92.7", "95.9", "", "", "", "", "95.2"]} +{"pcdb_id": 17877, "brand_name": "Grant", "model_name": "VortexBlue Internal Sealed System 36kW", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 59.0, "output_kw_max": 36.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017877", "000048", "0", "2020/Jan/15 12:19", "Grant Engineering", "Grant", "VortexBlue Internal Sealed System 36kW", "", "", "2017", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "26", "36", "", "", "88.6", "80.8", "", "59.0", "", "2", "", "", "201", "1", "1", "150", "1", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.1", "96.1", "", "", "", "", "95.2"]} +{"pcdb_id": 17878, "brand_name": "Grant", "model_name": "VortexBlue External 21kW", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 80.7, "comparative_hot_water_efficiency_pct": 58.9, "output_kw_max": 21.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017878", "000048", "0", "2020/Jan/15 12:20", "Grant Engineering", "Grant", "VortexBlue External 21kW", "", "", "2017", "current", "4", "1", "2", "1", "0", "", "", "2", "3", "2", "15", "21", "", "", "88.5", "80.7", "", "58.9", "", "2", "", "", "201", "1", "1", "143", "1", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.4", "95.8", "", "", "", "", "94.9"]} +{"pcdb_id": 17879, "brand_name": "Grant", "model_name": "VortexBlue External 26kW", "model_qualifier": "", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 80.9, "comparative_hot_water_efficiency_pct": 59.1, "output_kw_max": 26.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017879", "000048", "0", "2020/Apr/15 08:58", "Grant Engineering", "Grant", "VortexBlue External 26kW", "", "", "2017", "current", "4", "1", "2", "1", "0", "", "", "2", "3", "2", "26", "26", "", "", "88.7", "80.9", "", "59.1", "", "2", "", "", "201", "1", "1", "147", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "92.7", "95.9", "", "", "", "", "95.2"]} +{"pcdb_id": 17880, "brand_name": "Grant", "model_name": "VortexBlue External 36kW", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 59.0, "output_kw_max": 36.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017880", "000048", "0", "2020/Jan/15 12:20", "Grant Engineering", "Grant", "VortexBlue External 36kW", "", "", "2017", "current", "4", "1", "2", "1", "0", "", "", "2", "3", "2", "26", "36", "", "", "88.6", "80.8", "", "59.0", "", "2", "", "", "201", "1", "1", "150", "1", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.1", "96.1", "", "", "", "", "95.2"]} +{"pcdb_id": 17887, "brand_name": "Grant", "model_name": "Vortex PRO Combi XS 26", "model_qualifier": "", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 82.8, "comparative_hot_water_efficiency_pct": 45.3, "output_kw_max": 26.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 1, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017887", "000048", "0", "2024/Jan/31 10:17", "Grant Engineering", "Grant", "Vortex PRO Combi XS 26", "", "", "2016", "current", "4", "1", "1", "2", "0", "", "", "2", "3", "2", "26", "26", "", "", "88.9", "82.8", "", "45.3", "", "2", "", "", "203", "1", "1", "", "", "1", "", "", "40", "0", "25", "3", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "92.5", "96.4", "", "", "", "", "95.7"]} +{"pcdb_id": 17888, "brand_name": "Grant", "model_name": "VortexBlue Internal 36kW", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 59.0, "output_kw_max": 36.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017888", "000048", "0", "2020/Jan/15 12:19", "Grant Engineering", "Grant", "VortexBlue Internal 36kW", "", "", "2017", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "26", "36", "", "", "88.6", "80.8", "", "59.0", "", "2", "", "", "201", "1", "1", "150", "1", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.1", "96.1", "", "", "", "", "95.2"]} +{"pcdb_id": 17889, "brand_name": "Daikin", "model_name": "EHYKOMB33AA", "model_qualifier": "EHYKOMB33AAS", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 26.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017889", "000278", "0", "2016/Apr/11 16:37", "Daikin Europe NV", "Daikin", "EHYKOMB33AA", "EHYKOMB33AAS", "47-464-01", "2013", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "26.6", "26.6", "", "", "88.5", "79.5", "", "58.0", "", "2", "", "", "102", "1", "2", "55", "1.9", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.9", "97.6", "", "", "", "", "95.9"]} +{"pcdb_id": 17891, "brand_name": "Vokera", "model_name": "Excel", "model_qualifier": "25", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 56.1, "output_kw_max": 19.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017891", "000011", "0", "2016/Oct/24 11:40", "Vokera", "Vokera", "Excel", "25", "47 364 12", "2013", "current", "2", "2", "1", "2", "0", "", "", "2", "3", "2", "19.5", "19.5", "", "", "88.3", "79.7", "", "56.1", "", "2", "1", "", "104", "1", "2", "29", "6", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.9", "97.3", "", "", "", "", "95.9"]} +{"pcdb_id": 17892, "brand_name": "Vokera", "model_name": "Excel", "model_qualifier": "29", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 56.3, "output_kw_max": 24.45, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017892", "000011", "0", "2016/Oct/24 11:41", "Vokera", "Vokera", "Excel", "29", "47 364 13", "2013", "current", "2", "2", "1", "2", "0", "", "", "2", "3", "2", "24.45", "24.45", "", "", "88.6", "80.0", "", "56.3", "", "2", "1", "", "104", "1", "2", "38", "6", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.1", "98.0", "", "", "", "", "96.5"]} +{"pcdb_id": 17893, "brand_name": "Vokera", "model_name": "Vibe", "model_qualifier": "20A", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 19.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017893", "000011", "0", "2016/Oct/24 11:41", "Vokera", "Vokera", "Vibe", "20A", "41 094 84", "2014", "current", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "19.50", "19.50", "", "", "88.3", "79.3", "", "57.9", "", "2", "1", "", "102", "1", "2", "29", "6", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.9", "97.3", "", "", "", "", "95.9"]} +{"pcdb_id": 17894, "brand_name": "Vokera", "model_name": "Vibe", "model_qualifier": "25A", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 24.45, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017894", "000011", "0", "2016/Oct/24 11:41", "Vokera", "Vokera", "Vibe", "25A", "41 094 85", "2014", "current", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "24.45", "24.45", "", "", "88.6", "79.6", "", "58.2", "", "2", "1", "", "102", "1", "2", "38", "6", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.1", "98.0", "", "", "", "", "96.5"]} +{"pcdb_id": 17895, "brand_name": "Vokera", "model_name": "Compact", "model_qualifier": "25A", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 56.1, "output_kw_max": 19.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017895", "000011", "0", "2016/Oct/24 11:41", "Vokera", "Vokera", "Compact", "25A", "47 364 17", "2013", "current", "2", "2", "1", "2", "0", "", "", "2", "3", "2", "19.50", "19.50", "", "", "88.3", "79.7", "", "56.1", "", "2", "1", "", "104", "1", "2", "29", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.9", "97.3", "", "", "", "", "95.9"]} +{"pcdb_id": 17896, "brand_name": "Vokera", "model_name": "Compact", "model_qualifier": "29A", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 56.3, "output_kw_max": 24.45, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017896", "000011", "0", "2016/Oct/24 11:41", "Vokera", "Vokera", "Compact", "29A", "47 364 18", "2013", "current", "2", "2", "1", "2", "0", "", "", "2", "3", "2", "24.45", "24.45", "", "", "88.6", "80.0", "", "56.3", "", "2", "1", "", "104", "1", "2", "38", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.1", "98.0", "", "", "", "", "96.5"]} +{"pcdb_id": 17899, "brand_name": "Ferroli", "model_name": "MODENA 38C HE", "model_qualifier": "47-267-63", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 86.8, "comparative_hot_water_efficiency_pct": 68.3, "output_kw_max": 34.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.005, "loss_factor_f1_kwh_per_day": 1.55696, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017899", "000097", "0", "2016/Apr/20 10:18", "Ferroli", "Ferroli", "MODENA 38C HE", "47-267-63", "", "2015", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "34.3", "34.3", "", "", "88.5", "86.8", "", "68.3", "", "2", "", "", "104", "1", "2", "110", "3", "0", "", "", "", "0", "", "", "", "", "1", "7.715", "0.0589", "0.005", "1.55696", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "98.0", "", "", "", "", "96.2"]} +{"pcdb_id": 17900, "brand_name": "Ferroli", "model_name": "FERcondens", "model_qualifier": "25 HE", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 86.6, "comparative_hot_water_efficiency_pct": 56.9, "output_kw_max": 24.4, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0036, "loss_factor_f1_kwh_per_day": 3.03782, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017900", "000097", "0", "2016/Apr/25 16:47", "Ferroli", "Ferroli", "FERcondens", "25 HE", "", "2013", "2015", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.4", "24.4", "", "", "87.9", "86.6", "", "56.9", "", "2", "", "", "104", "1", "2", "58", "3", "0", "", "", "", "0", "", "", "", "", "1", "9.26", "0.07469", "0.0036", "3.03782", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "96.5", "", "", "", "", "94.9"]} +{"pcdb_id": 17902, "brand_name": "Worcester", "model_name": "GB162-50 V2", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 46.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017902", "000035", "0", "2016/May/18 11:07", "Worcester Bosch Group", "Worcester", "GB162-50 V2", "", "", "2016", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "46.6", "46.6", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "41", "6", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.5", "97.0", "", "", "", "", "95.2"]} +{"pcdb_id": 17903, "brand_name": "Worcester", "model_name": "GB162-65 V2", "model_qualifier": "", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 78.9, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 62.9, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017903", "000035", "0", "2016/May/18 11:08", "Worcester Bosch Group", "Worcester", "GB162-65 V2", "", "", "2016", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "62.9", "62.9", "", "", "87.9", "78.9", "", "57.7", "", "2", "", "", "102", "1", "2", "82", "6", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.3", "96.9", "", "", "", "", "95.1"]} +{"pcdb_id": 17904, "brand_name": "Vokera", "model_name": "Easi-Heat Plus 25C", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 56.2, "output_kw_max": 19.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017904", "000011", "0", "2016/Jun/01 09:15", "Vokera", "Vokera", "Easi-Heat Plus 25C", "", "47-364-29", "2016", "current", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "19.5", "19.5", "", "", "88.5", "79.9", "", "56.2", "", "2", "", "", "104", "1", "2", "29", "6", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "98.1", "", "", "", "", "96.2"]} +{"pcdb_id": 17905, "brand_name": "Vokera", "model_name": "Easi-Heat Plus 29C", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 56.1, "output_kw_max": 24.45, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017905", "000011", "0", "2016/Jun/01 09:16", "Vokera", "Vokera", "Easi-Heat Plus 29C", "", "47-364-30", "2016", "current", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "24.45", "24.45", "", "", "88.4", "79.8", "", "56.1", "", "2", "", "", "104", "1", "2", "38", "6", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.1", "97.7", "", "", "", "", "95.9"]} +{"pcdb_id": 17906, "brand_name": "Glow-worm", "model_name": "Betacom3 24c", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 56.3, "output_kw_max": 20.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017906", "000207", "0", "2016/Jun/01 10:03", "Glow-worm", "Glow-worm", "Betacom3 24c", "", "47-019-41", "2016", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "20.3", "20.3", "", "", "88.6", "80.0", "", "56.3", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.6", "97.8", "", "", "", "", "96.2"]} +{"pcdb_id": 17908, "brand_name": "Glow-worm", "model_name": "Betacom3 30c", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 56.3, "output_kw_max": 15.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017908", "000207", "0", "2016/Jun/01 10:03", "Glow-worm", "Glow-worm", "Betacom3 30c", "", "47-019-42", "2016", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "15.2", "15.2", "", "", "88.6", "80.0", "", "56.3", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.6", "97.8", "", "", "", "", "96.2"]} +{"pcdb_id": 17909, "brand_name": "Vaillant", "model_name": "ecoTEC plus 624 H system A", "model_qualifier": "VU GB 246/5-5 A R4", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 24.4, "final_year_of_manufacture": 2017, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017909", "000031", "0", "2019/Mar/04 10:10", "Vaillant", "Vaillant", "ecoTEC plus 624 H system A", "VU GB 246/5-5 A R4", "41-044-82", "2015", "2017", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "24.4", "24.4", "", "", "89.2", "80.2", "", "58.6", "", "2", "0", "", "102", "1", "2", "29", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.7", "97.1", "", "", "", "", "95.7"]} +{"pcdb_id": 17910, "brand_name": "Vaillant", "model_name": "ecoTEC plus 637 H system A", "model_qualifier": "VU GB 376/5-5 A R4", "winter_efficiency_pct": 89.8, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 59.0, "output_kw_max": 37.9, "final_year_of_manufacture": 2017, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017910", "000031", "0", "2019/Mar/04 10:11", "Vaillant", "Vaillant", "ecoTEC plus 637 H system A", "VU GB 376/5-5 A R4", "41-044-85", "2015", "2017", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "37.9", "37.9", "", "", "89.8", "80.8", "", "59.0", "", "2", "0", "", "102", "1", "2", "45", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.1", "98.4", "", "", "", "", "96.8"]} +{"pcdb_id": 17912, "brand_name": "Vaillant", "model_name": "ecoTEC plus 825 H combi A", "model_qualifier": "VUW GB 256/5-5 R4", "winter_efficiency_pct": 89.5, "summer_efficiency_pct": 80.9, "comparative_hot_water_efficiency_pct": 56.9, "output_kw_max": 19.0, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017912", "000031", "0", "2019/Mar/04 10:14", "Vaillant", "Vaillant", "ecoTEC plus 825 H combi A", "VUW GB 256/5-5 R4", "41-044-57", "2015", "2015", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "19.0", "19.0", "", "", "89.5", "80.9", "", "56.9", "", "2", "0", "", "104", "1", "2", "29", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "", "", "0005", "", "", "", "", "", "", "", "", "89.8", "97.8", "", "", "", "", "96.3"]} +{"pcdb_id": 17913, "brand_name": "Vaillant", "model_name": "ecoTEC plus 835 H combi A", "model_qualifier": "VUW GB 356/5-5 R4", "winter_efficiency_pct": 89.5, "summer_efficiency_pct": 80.9, "comparative_hot_water_efficiency_pct": 56.9, "output_kw_max": 30.4, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017913", "000031", "0", "2019/Mar/04 10:15", "Vaillant", "Vaillant", "ecoTEC plus 835 H combi A", "VUW GB 356/5-5 R4", "41-044-53", "2015", "2015", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "30.4", "30.4", "", "", "89.5", "80.9", "", "56.9", "", "2", "0", "", "104", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "", "", "0005", "", "", "", "", "", "", "", "", "89.8", "97.8", "", "", "", "", "96.3"]} +{"pcdb_id": 17914, "brand_name": "Vaillant", "model_name": "ecoTEC plus 838 H combi A", "model_qualifier": "VUW GB 386/5-5 A R4", "winter_efficiency_pct": 89.6, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 56.9, "output_kw_max": 28.6, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017914", "000031", "0", "2019/Mar/04 10:21", "Vaillant", "Vaillant", "ecoTEC plus 838 H combi A", "VUW GB 386/5-5 A R4", "41-044-60", "2015", "2015", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "28.6", "28.6", "", "", "89.6", "81.0", "", "56.9", "", "2", "0", "", "104", "1", "2", "28", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "", "", "0005", "", "", "", "", "", "", "", "", "90.3", "97.7", "", "", "", "", "96.3"]} +{"pcdb_id": 17915, "brand_name": "Vaillant", "model_name": "ecoTEC plus 938 H combi A", "model_qualifier": "VUI GB 386/5-5 A R4", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 80.6, "comparative_hot_water_efficiency_pct": 56.7, "output_kw_max": 28.3, "final_year_of_manufacture": 2015, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017915", "000031", "0", "2019/Mar/04 10:24", "Vaillant", "Vaillant", "ecoTEC plus 938 H combi A", "VUI GB 386/5-5 A R4", "41-044-61", "2015", "2015", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "28.3", "28.3", "", "", "89.2", "80.6", "", "56.7", "", "2", "0", "", "104", "1", "2", "28", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "", "", "0005", "", "", "", "", "", "", "", "", "90.1", "96.8", "", "", "", "", "95.5"]} +{"pcdb_id": 17916, "brand_name": "Vaillant", "model_name": "ecoTEC pro 24 H combi A", "model_qualifier": "VUW GB 246/5-3 A R4", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 56.6, "output_kw_max": 18.4, "final_year_of_manufacture": 2017, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017916", "000031", "0", "2019/Mar/04 10:28", "Vaillant", "Vaillant", "ecoTEC pro 24 H combi A", "VUW GB 246/5-3 A R4", "47-044-54", "2015", "2017", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "18.4", "18.4", "", "", "89.1", "80.5", "", "56.6", "", "2", "0", "", "104", "1", "2", "26", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "", "", "0005", "", "", "", "", "", "", "", "", "89.9", "96.5", "", "", "", "", "95.3"]} +{"pcdb_id": 17917, "brand_name": "Vaillant", "model_name": "ecoTEC pro 30 H combi A", "model_qualifier": "VUW GB 306/5-3 R4", "winter_efficiency_pct": 89.5, "summer_efficiency_pct": 80.9, "comparative_hot_water_efficiency_pct": 56.9, "output_kw_max": 24.3, "final_year_of_manufacture": 2017, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017917", "000031", "0", "2019/Mar/04 10:33", "Vaillant", "Vaillant", "ecoTEC pro 30 H combi A", "VUW GB 306/5-3 R4", "47-044-52", "2015", "2017", "2", "2", "1", "2", "0", "", "", "2", "2", "1", "24.3", "24.3", "", "", "89.5", "80.9", "", "56.9", "", "2", "0", "", "104", "1", "2", "42", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "", "", "0005", "", "", "", "", "", "", "", "", "89.5", "97.7", "", "", "", "", "96.2"]} +{"pcdb_id": 17918, "brand_name": "Navien", "model_name": "NCB-24LDWE", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 86.6, "comparative_hot_water_efficiency_pct": 69.6, "output_kw_max": 19.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0115, "loss_factor_f1_kwh_per_day": 1.36183, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017918", "000265", "0", "2020/Jun/02 08:31", "KD Navien", "Navien", "NCB-24LDWE", "", "47-709-01", "2014", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "19.5", "19.5", "", "", "88.4", "86.6", "", "69.6", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "", "0", "", "", "", "", "1", "7.565", "0.209", "0.0115", "1.36183", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "87.8", "97.8", "", "", "", "", "95.9"]} +{"pcdb_id": 17919, "brand_name": "Navien", "model_name": "NCB-28LDWE", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 86.6, "comparative_hot_water_efficiency_pct": 68.8, "output_kw_max": 23.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.006, "loss_factor_f1_kwh_per_day": 1.47667, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017919", "000265", "0", "2020/Jun/02 08:43", "KD Navien", "Navien", "NCB-28LDWE", "", "47-709-02", "2014", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "23.4", "23.4", "", "", "88.5", "86.6", "", "68.8", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "", "0", "", "", "", "", "1", "7.651", "0.235", "0.006", "1.47667", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "87.8", "98.1", "", "", "", "", "96.2"]} +{"pcdb_id": 17920, "brand_name": "Navien", "model_name": "NCB-34LDWE", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 86.7, "comparative_hot_water_efficiency_pct": 69.1, "output_kw_max": 28.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0025, "loss_factor_f1_kwh_per_day": 1.4727, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017920", "000265", "0", "2020/Jun/02 08:49", "KD Navien", "Navien", "NCB-34LDWE", "", "47-709-03", "2014", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28.3", "28.3", "", "", "88.4", "86.7", "", "69.1", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "", "0", "", "", "", "", "1", "7.623", "0.224", "0.0025", "1.4727", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "87.9", "97.8", "", "", "", "", "95.9"]} +{"pcdb_id": 17921, "brand_name": "Navien", "model_name": "NCB-40LDWE", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 86.7, "comparative_hot_water_efficiency_pct": 69.4, "output_kw_max": 33.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.005, "loss_factor_f1_kwh_per_day": 1.42923, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017921", "000265", "0", "2020/Jun/02 08:55", "KD Navien", "Navien", "NCB-40LDWE", "", "47-709-04", "2014", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "33.2", "33.2", "", "", "88.5", "86.7", "", "69.4", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "", "0", "", "", "", "", "1", "7.593", "0.223", "0.005", "1.42923", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "87.9", "98.0", "", "", "", "", "96.1"]} +{"pcdb_id": 17922, "brand_name": "Potterton", "model_name": "PROMAX ULTRA COMBI 24 ErP", "model_qualifier": "", "winter_efficiency_pct": 89.5, "summer_efficiency_pct": 80.9, "comparative_hot_water_efficiency_pct": 56.9, "output_kw_max": 20.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017922", "000005", "0", "2016/Jun/20 15:32", "Baxi Heating UK", "Potterton", "PROMAX ULTRA COMBI 24 ErP", "", "GC No. 47-393-54", "2015", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "20", "20", "", "", "89.5", "80.9", "", "56.9", "", "2", "1", "", "104", "1", "2", "85", "3", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.0", "100.2", "", "", "", "", "98.3"]} +{"pcdb_id": 17923, "brand_name": "Potterton", "model_name": "PROMAX ULTRA COMBI 28 ErP", "model_qualifier": "", "winter_efficiency_pct": 89.5, "summer_efficiency_pct": 80.9, "comparative_hot_water_efficiency_pct": 56.9, "output_kw_max": 24.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017923", "000005", "0", "2016/Jun/20 15:32", "Baxi Heating UK", "Potterton", "PROMAX ULTRA COMBI 28 ErP", "", "GC No. 47-393-55", "2015", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "89.5", "80.9", "", "56.9", "", "2", "1", "", "104", "1", "2", "90", "3", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.9", "100.2", "", "", "", "", "98.2"]} +{"pcdb_id": 17925, "brand_name": "Potterton", "model_name": "PROMAX ULTRA COMBI 33 ErP", "model_qualifier": "", "winter_efficiency_pct": 89.6, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 56.9, "output_kw_max": 28.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017925", "000005", "0", "2016/Jun/20 15:32", "Baxi Heating UK", "Potterton", "PROMAX ULTRA COMBI 33 ErP", "", "GC No. 47-393-56", "2015", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "28", "28", "", "", "89.6", "81.0", "", "56.9", "", "2", "1", "", "104", "1", "2", "95", "3", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.1", "100.3", "", "", "", "", "98.4"]} +{"pcdb_id": 17926, "brand_name": "Potterton", "model_name": "PROMAX ULTRA COMBI 40 ErP", "model_qualifier": "", "winter_efficiency_pct": 89.5, "summer_efficiency_pct": 80.9, "comparative_hot_water_efficiency_pct": 56.9, "output_kw_max": 32.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017926", "000005", "0", "2016/Jun/20 15:33", "Baxi Heating UK", "Potterton", "PROMAX ULTRA COMBI 40 ErP", "", "GC No. 47-393-57", "2015", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "32", "32", "", "", "89.5", "80.9", "", "56.9", "", "2", "1", "", "104", "1", "2", "100", "3", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.9", "100.2", "", "", "", "", "98.2"]} +{"pcdb_id": 17927, "brand_name": "Baxi", "model_name": "124 COMBI", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 86.7, "comparative_hot_water_efficiency_pct": 77.6, "output_kw_max": 20.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0043, "loss_factor_f1_kwh_per_day": 0.65911, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017927", "000005", "0", "2016/Jul/20 12:18", "Baxi Heating UK", "Baxi", "124 COMBI", "", "47-077-25", "2016", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "20", "20", "", "", "88.5", "86.7", "", "77.6", "", "2", "", "", "104", "1", "2", "42", "3", "0", "", "", "", "0", "", "", "", "", "1", "6.786", "0.098", "0.0043", "0.65911", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "98.0", "", "", "", "", "96.1"]} +{"pcdb_id": 17928, "brand_name": "Baxi", "model_name": "128 COMBI", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 86.7, "comparative_hot_water_efficiency_pct": 77.3, "output_kw_max": 24.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0044, "loss_factor_f1_kwh_per_day": 0.68225, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017928", "000005", "0", "2016/Jul/20 12:18", "Baxi Heating UK", "Baxi", "128 COMBI", "", "47-077-26", "2016", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "88.5", "86.7", "", "77.3", "", "2", "", "", "104", "1", "2", "42", "3", "0", "", "", "", "0", "", "", "", "", "1", "6.813", "0.098", "0.0044", "0.68225", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "98.0", "", "", "", "", "96.1"]} +{"pcdb_id": 17929, "brand_name": "Ideal", "model_name": "LOGIC COMBI", "model_qualifier": "ESP1 35", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 81.0, "output_kw_max": 24.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0024, "loss_factor_f1_kwh_per_day": 0.44376, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017929", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "LOGIC COMBI", "ESP1 35", "47-349-23", "2016", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "89.0", "87.3", "", "81.0", "", "2", "", "", "104", "1", "2", "42", "5", "0", "", "", "", "0", "", "", "", "", "1", "6.502", "0.074", "0.0024", "0.44376", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "", "", "", "", "90.0", "98.6", "", "", "", "", "96.9"]} +{"pcdb_id": 17930, "brand_name": "Viessmann", "model_name": "Vitodens 100-W", "model_qualifier": "B1KC-35", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 88.2, "comparative_hot_water_efficiency_pct": 73.2, "output_kw_max": 32.1, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.0, "loss_factor_f1_kwh_per_day": 1.07553, "loss_factor_f2_kwh_per_day": 1.05261, "rejected_factor_f3_per_litre": 0.0, "raw": ["017930", "000033", "0", "2020/Apr/09 16:05", "Viessmann", "Viessmann", "Vitodens 100-W", "B1KC-35", "47-819-42", "2016", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "32.1", "32.1", "", "", "88.5", "88.2", "", "73.2", "", "2", "", "", "104", "1", "2", "25", "58", "0", "", "", "", "0", "", "", "", "", "2", "7.19", "0.142", "0.0", "1.07553", "13.03", "0.161", "0.0", "1.05261", "0.0", "", "", "", "0035", "", "", "", "", "", "", "", "", "88.1", "97.9", "", "", "", "", "96.1"]} +{"pcdb_id": 17931, "brand_name": "Viessmann", "model_name": "Vitodens 100-W", "model_qualifier": "B1KC-30", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 88.2, "comparative_hot_water_efficiency_pct": 71.2, "output_kw_max": 27.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.0, "loss_factor_f1_kwh_per_day": 1.28491, "loss_factor_f2_kwh_per_day": 1.25407, "rejected_factor_f3_per_litre": 0.0, "raw": ["017931", "000033", "0", "2020/Apr/09 16:05", "Viessmann", "Viessmann", "Vitodens 100-W", "B1KC-30", "47-819-41", "2016", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "27.5", "27.5", "", "", "88.5", "88.2", "", "71.2", "", "2", "", "", "104", "1", "2", "24", "58", "0", "", "", "", "0", "", "", "", "", "2", "7.4", "0.155", "0.0", "1.28491", "13.12", "0.174", "0.0", "1.25407", "0.0", "", "", "", "0035", "", "", "", "", "", "", "", "", "88.4", "97.8", "", "", "", "", "96.1"]} +{"pcdb_id": 17932, "brand_name": "Viessmann", "model_name": "Vitodens 100-W", "model_qualifier": "B1KC-26", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 87.8, "comparative_hot_water_efficiency_pct": 66.8, "output_kw_max": 23.8, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.0, "loss_factor_f1_kwh_per_day": 1.73709, "loss_factor_f2_kwh_per_day": 1.68304, "rejected_factor_f3_per_litre": 0.0, "raw": ["017932", "000033", "0", "2020/Apr/09 16:04", "Viessmann", "Viessmann", "Vitodens 100-W", "B1KC-26", "47-819-40", "2016", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "23.8", "23.8", "", "", "88.1", "87.8", "", "66.8", "", "2", "", "", "104", "1", "2", "22", "59", "0", "", "", "", "0", "", "", "", "", "2", "7.88", "0.153", "0.0", "1.73709", "13.84", "0.175", "0.0", "1.68304", "0.0", "", "", "", "0035", "", "", "", "", "", "", "", "", "88.0", "97.0", "", "", "", "", "95.3"]} +{"pcdb_id": 17933, "brand_name": "Viessmann", "model_name": "Vitodens 100-W", "model_qualifier": "B1HC-35", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 32.1, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017933", "000033", "0", "2017/Feb/20 10:57", "Viessmann", "Viessmann", "Vitodens 100-W", "B1HC-35", "41-819-43", "2016", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "32.1", "32.1", "", "", "88.5", "79.5", "", "58.0", "", "2", "", "", "102", "1", "2", "25", "58", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "", "", "", "", "88.1", "97.9", "", "", "", "", "96.1"]} +{"pcdb_id": 17934, "brand_name": "Viessmann", "model_name": "Vitodens 100-W", "model_qualifier": "B1HC-30", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 27.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017934", "000033", "0", "2017/Feb/20 10:57", "Viessmann", "Viessmann", "Vitodens 100-W", "B1HC-30", "41-819-42", "2016", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "27.5", "27.5", "", "", "88.5", "79.5", "", "58.1", "", "2", "", "", "102", "1", "2", "24", "58", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "", "", "", "", "88.4", "97.8", "", "", "", "", "96.1"]} +{"pcdb_id": 17935, "brand_name": "Viessmann", "model_name": "Vitodens 100-W", "model_qualifier": "B1HC-26", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 23.8, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017935", "000033", "0", "2017/Feb/20 10:57", "Viessmann", "Viessmann", "Vitodens 100-W", "B1HC-26", "41-819-41", "2016", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "23.8", "23.8", "", "", "88.1", "79.1", "", "57.8", "", "2", "", "", "102", "1", "2", "22", "59", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "", "", "", "", "88.0", "97.0", "", "", "", "", "95.3"]} +{"pcdb_id": 17936, "brand_name": "Viessmann", "model_name": "Vitodens 100-W", "model_qualifier": "B1HC-19", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 17.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017936", "000033", "0", "2017/Feb/20 10:57", "Viessmann", "Viessmann", "Vitodens 100-W", "B1HC-19", "41-819-40", "2016", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "17.4", "17.4", "", "", "88.3", "79.3", "", "57.9", "", "2", "", "", "102", "1", "2", "19", "60", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "", "", "", "", "87.8", "97.7", "", "", "", "", "95.8"]} +{"pcdb_id": 17937, "brand_name": "Viessmann", "model_name": "Vitodens 111-W", "model_qualifier": "B1LD - 35kW", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 86.2, "comparative_hot_water_efficiency_pct": 59.3, "output_kw_max": 32.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 1, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.0, "loss_factor_f1_kwh_per_day": 2.71671, "loss_factor_f2_kwh_per_day": 2.48464, "rejected_factor_f3_per_litre": 0.0, "raw": ["017937", "000033", "0", "2020/Apr/09 16:03", "Viessmann", "Viessmann", "Vitodens 111-W", "B1LD - 35kW", "", "2016", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "32", "32", "", "", "88.5", "86.2", "", "59.3", "", "2", "", "", "106", "1", "2", "25", "58", "1", "", "0", "46", "0", "10", "2", "", "", "2", "8.88", "0.173", "0.0", "2.71671", "14.95", "0.205", "0.0", "2.48464", "0.0", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.6", "97.8", "", "", "", "", "96.1"]} +{"pcdb_id": 17938, "brand_name": "Viessmann", "model_name": "Vitodens 111-W", "model_qualifier": "B1LD - 26kW", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 87.1, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 23.8, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 1, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.0, "loss_factor_f1_kwh_per_day": 2.85619, "loss_factor_f2_kwh_per_day": 2.7211, "rejected_factor_f3_per_litre": 0.0, "raw": ["017938", "000033", "0", "2020/Apr/09 16:02", "Viessmann", "Viessmann", "Vitodens 111-W", "B1LD - 26kW", "", "2016", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "23.8", "23.8", "", "", "88.4", "87.1", "", "58.3", "", "2", "", "", "106", "1", "2", "22", "59", "1", "1", "0", "46", "0", "10", "2", "", "", "2", "9.04", "0.177", "0.0", "2.85619", "15.05", "0.214", "0.0001", "2.7211", "0.0", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.1", "97.8", "", "", "", "", "95.9"]} +{"pcdb_id": 17939, "brand_name": "Baxi", "model_name": "200", "model_qualifier": "224 COMBI", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 56.1, "output_kw_max": 20.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017939", "000005", "0", "2021/Feb/18 10:24", "Baxi Heating UK", "Baxi", "200", "224 COMBI", "47-077-21", "2016", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "20", "20", "", "", "88.4", "79.8", "", "56.1", "", "2", "", "", "104", "1", "2", "28", "3", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "88.1", "97.8", "", "", "", "", "96.0"]} +{"pcdb_id": 17940, "brand_name": "Baxi", "model_name": "200", "model_qualifier": "228 COMBI", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 56.1, "output_kw_max": 24.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017940", "000005", "0", "2021/Feb/18 10:29", "Baxi Heating UK", "Baxi", "200", "228 COMBI", "47-077-22", "2016", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "88.4", "79.8", "", "56.1", "", "2", "", "", "104", "1", "2", "38", "3", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "88.0", "97.8", "", "", "", "", "95.9"]} +{"pcdb_id": 17941, "brand_name": "Baxi", "model_name": "400", "model_qualifier": "424 COMBI", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 56.1, "output_kw_max": 20.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017941", "000005", "0", "2021/Feb/18 10:33", "Baxi Heating UK", "Baxi", "400", "424 COMBI", "47-077-23", "2016", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "20", "20", "", "", "88.4", "79.8", "", "56.1", "", "2", "", "", "104", "1", "2", "28", "3", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "88.1", "97.8", "", "", "", "", "96.0"]} +{"pcdb_id": 17942, "brand_name": "Baxi", "model_name": "400", "model_qualifier": "428 COMBI", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 56.1, "output_kw_max": 24.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017942", "000005", "0", "2021/Feb/18 10:36", "Baxi Heating UK", "Baxi", "400", "428 COMBI", "47-077-24", "2016", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "88.4", "79.8", "", "56.1", "", "2", "", "", "104", "1", "2", "38", "3", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "88.0", "97.8", "", "", "", "", "95.9"]} +{"pcdb_id": 17943, "brand_name": "Vokera", "model_name": "Maxim", "model_qualifier": "25", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 86.6, "comparative_hot_water_efficiency_pct": 72.1, "output_kw_max": 19.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.004, "loss_factor_f1_kwh_per_day": 1.15471, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017943", "000011", "0", "2016/Aug/22 13:28", "Vokera", "Vokera", "Maxim", "25", "47-364-31", "2016", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "19.5", "19.5", "", "", "88.5", "86.6", "", "72.1", "", "2", "", "", "104", "1", "2", "29", "6", "0", "", "", "", "0", "", "", "", "", "1", "7.304", "0.103", "0.004", "1.15471", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "98.1", "", "", "", "", "96.2"]} +{"pcdb_id": 17944, "brand_name": "Vokera", "model_name": "Maxim", "model_qualifier": "29", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 86.7, "comparative_hot_water_efficiency_pct": 72.9, "output_kw_max": 24.45, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.009, "loss_factor_f1_kwh_per_day": 1.0518, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017944", "000011", "0", "2016/Aug/22 13:28", "Vokera", "Vokera", "Maxim", "29", "47-364-32", "2016", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.45", "24.45", "", "", "88.4", "86.7", "", "72.9", "", "2", "", "", "104", "1", "2", "38", "6", "0", "", "", "", "0", "", "", "", "", "1", "7.22", "0.117", "0.009", "1.0518", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.1", "97.7", "", "", "", "", "95.9"]} +{"pcdb_id": 17945, "brand_name": "Biasi", "model_name": "ALNOVIA 18R", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 17.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017945", "000263", "0", "2016/Oct/03 11:09", "Unical AG", "Biasi", "ALNOVIA 18R", "", "41011161", "2016", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "17.4", "17.4", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "85", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.1", "97.8", "", "", "", "", "95.9"]} +{"pcdb_id": 17946, "brand_name": "Biasi", "model_name": "ALNOVIA 18S", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 56.1, "output_kw_max": 17.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017946", "000263", "0", "2016/Oct/03 11:10", "Unical AG", "Biasi", "ALNOVIA 18S", "", "41011159", "2016", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "17.4", "17.4", "", "", "88.4", "79.8", "", "56.1", "", "2", "", "", "104", "1", "2", "85", "3", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.1", "97.8", "", "", "", "", "95.9"]} +{"pcdb_id": 17947, "brand_name": "Biasi", "model_name": "ALNOVIA 28R", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 27.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017947", "000263", "0", "2016/Oct/03 11:10", "Unical AG", "Biasi", "ALNOVIA 28R", "", "41011165", "2016", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "27.2", "27.2", "", "", "88.5", "79.5", "", "58.0", "", "2", "", "", "102", "1", "2", "11", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "97.9", "", "", "", "", "96.1"]} +{"pcdb_id": 17948, "brand_name": "Biasi", "model_name": "ALNOVIA 28S", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 56.2, "output_kw_max": 27.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017948", "000263", "0", "2016/Oct/03 11:10", "Unical AG", "Biasi", "ALNOVIA 28S", "", "41011163", "2016", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "27.2", "27.2", "", "", "88.5", "79.9", "", "56.2", "", "2", "", "", "104", "1", "2", "11", "3", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "97.9", "", "", "", "", "96.1"]} +{"pcdb_id": 17949, "brand_name": "Elco", "model_name": "THISION S PLUS 46", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 44.7, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017949", "000303", "0", "2017/Apr/05 08:19", "Elco Heating Solutions Ltd", "Elco", "THISION S PLUS 46", "", "", "2016", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "44.7", "44.7", "", "", "88.8", "79.8", "", "58.3", "", "2", "", "", "102", "1", "2", "125", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "98.8", "", "", "", "", "96.8"]} +{"pcdb_id": 17950, "brand_name": "Elco", "model_name": "THISION S PLUS 54", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 52.9, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017950", "000303", "0", "2016/Nov/16 10:56", "Elco Heating Solutions Ltd", "Elco", "THISION S PLUS 54", "", "", "2016", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "52.9", "52.9", "", "", "88.8", "79.8", "", "58.3", "", "2", "", "", "102", "1", "2", "143", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "98.8", "", "", "", "", "96.8"]} +{"pcdb_id": 17951, "brand_name": "Elco", "model_name": "THISION S PLUS 34", "model_qualifier": "", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 33.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017951", "000303", "0", "2016/Nov/16 10:56", "Elco Heating Solutions Ltd", "Elco", "THISION S PLUS 34", "", "", "2016", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "33.6", "33.6", "", "", "88.7", "79.7", "", "58.3", "", "2", "", "", "102", "1", "2", "93", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "98.7", "", "", "", "", "96.7"]} +{"pcdb_id": 17952, "brand_name": "Vaillant", "model_name": "ecoTEC exclusive 627", "model_qualifier": "VU 256/5-7 (H-GB)", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 25.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017952", "000031", "0", "2018/Apr/03 14:01", "Vaillant", "Vaillant", "ecoTEC exclusive 627", "VU 256/5-7 (H-GB)", "41-694-02", "2016", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "25", "25", "", "", "88.9", "79.9", "", "58.4", "", "2", "", "", "102", "1", "2", "32", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0045", "", "", "", "", "", "", "", "", "89.0", "98.7", "", "", "", "", "96.9"]} +{"pcdb_id": 17953, "brand_name": "Vaillant", "model_name": "ecoTEC exclusive 835", "model_qualifier": "VUW 356/5-7 (H-GB)", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 85.0, "comparative_hot_water_efficiency_pct": 84.6, "output_kw_max": 32.7, "final_year_of_manufacture": null, "subsidiary_type": 1, "store_type": 0, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.006, "loss_factor_f1_kwh_per_day": 0.13712, "loss_factor_f2_kwh_per_day": 0.0, "rejected_factor_f3_per_litre": 6e-05, "raw": ["017953", "000031", "0", "2021/Feb/15 12:59", "Vaillant", "Vaillant", "ecoTEC exclusive 835", "VUW 356/5-7 (H-GB)", "47-044-66", "2016", "current", "1", "2", "1", "2", "1", "", "", "2", "2", "2", "32.7", "32.7", "", "", "89.1", "85.0", "", "84.6", "", "2", "", "", "104", "1", "2", "31", "2", "0", "", "", "", "0", "", "", "", "", "2", "6.224", "0.081", "0.006", "0.13712", "12.3532", "0.0833", "0.0005", "0.0", "0.00006", "", "", "", "0045", "", "", "", "", "", "", "", "", "89.3", "99.0", "", "", "", "", "97.2"]} +{"pcdb_id": 17954, "brand_name": "Vaillant", "model_name": "ecoTEC exclusive 843", "model_qualifier": "VUW 436/5-7 (H-GB)", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 83.8, "comparative_hot_water_efficiency_pct": 86.9, "output_kw_max": 40.2, "final_year_of_manufacture": null, "subsidiary_type": 1, "store_type": 0, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.006, "loss_factor_f1_kwh_per_day": 0.0, "loss_factor_f2_kwh_per_day": 0.0, "rejected_factor_f3_per_litre": 5e-05, "raw": ["017954", "000031", "0", "2020/Nov/17 08:45", "Vaillant", "Vaillant", "ecoTEC exclusive 843", "VUW 436/5-7 (H-GB)", "47-044-67", "2016", "current", "1", "2", "1", "2", "1", "", "", "2", "2", "2", "40.2", "40.2", "", "", "89.0", "83.8", "", "86.9", "", "2", "", "", "104", "1", "2", "31", "2", "0", "", "", "", "0", "", "", "", "", "2", "6.057", "0.081", "0.006", "0.0", "12.277", "0.1149", "0.0009", "0.0", "0.00005", "", "", "", "0045", "", "", "", "", "", "", "", "", "89.1", "98.9", "", "", "", "", "97.1"]} +{"pcdb_id": 17955, "brand_name": "Ideal", "model_name": "LOGIC COMBI", "model_qualifier": "ESP1 24", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 80.1, "output_kw_max": 24.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0042, "loss_factor_f1_kwh_per_day": 0.50397, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017955", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "LOGIC COMBI", "ESP1 24", "47-349-21", "2016", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "89.0", "87.3", "", "80.1", "", "2", "", "", "104", "1", "2", "29", "5", "0", "", "", "", "0", "", "", "", "", "1", "6.575", "0.075", "0.0042", "0.50397", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "", "", "", "", "90.0", "98.6", "", "", "", "", "96.9"]} +{"pcdb_id": 17956, "brand_name": "Ideal", "model_name": "LOGIC COMBI", "model_qualifier": "ESP1 30", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 80.8, "output_kw_max": 24.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.003, "loss_factor_f1_kwh_per_day": 0.45861, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017956", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "LOGIC COMBI", "ESP1 30", "47-349-22", "2016", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "89.0", "87.3", "", "80.8", "", "2", "", "", "104", "1", "2", "31", "5", "0", "", "", "", "0", "", "", "", "", "1", "6.521", "0.074", "0.003", "0.45861", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "", "", "", "", "90.0", "98.6", "", "", "", "", "96.9"]} +{"pcdb_id": 17957, "brand_name": "Warmflow", "model_name": "UTILITY COMBI 70 HE ECO", "model_qualifier": "UC70HEE", "winter_efficiency_pct": 87.5, "summer_efficiency_pct": 81.5, "comparative_hot_water_efficiency_pct": 52.4, "output_kw_max": 21.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 1, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017957", "000063", "0", "2024/Jan/31 10:17", "Warmflow Engineering", "Warmflow", "UTILITY COMBI 70 HE ECO", "UC70HEE", "", "2016", "current", "4", "1", "1", "2", "0", "", "", "2", "3", "2", "21.0", "21.0", "", "", "87.5", "81.5", "", "52.4", "", "2", "", "", "203", "1", "1", "200", "0", "1", "2", "", "50", "0", "50", "2", "55", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.3", "93.3", "", "", "", "", "92.9"]} +{"pcdb_id": 17958, "brand_name": "Vaillant", "model_name": "ecoFIT sustain 825", "model_qualifier": "VUW 256/6-3 (H-GB)", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 75.0, "comparative_hot_water_efficiency_pct": 77.0, "output_kw_max": 18.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.0115, "loss_factor_f1_kwh_per_day": 0.70684, "loss_factor_f2_kwh_per_day": 0.0, "rejected_factor_f3_per_litre": 0.0001, "raw": ["017958", "000031", "0", "2020/Nov/23 12:20", "Vaillant", "Vaillant", "ecoFIT sustain 825", "VUW 256/6-3 (H-GB)", "47-044-71", "2016", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "18.3", "18.3", "", "", "88.7", "75.0", "", "77.0", "", "2", "", "", "104", "1", "2", "25", "2", "0", "", "", "", "0", "", "", "", "", "2", "6.835", "0.096", "0.0115", "0.70684", "13.761", "0.11", "0.002", "0.0", "0.0001", "", "", "", "0045", "", "", "", "", "", "", "", "", "89.7", "97.8", "", "", "", "", "96.2"]} +{"pcdb_id": 17959, "brand_name": "Vaillant", "model_name": "ecoFIT sustain 830", "model_qualifier": "VUW 306/6-3 (H-GB)", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 76.2, "comparative_hot_water_efficiency_pct": 75.8, "output_kw_max": 18.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.0115, "loss_factor_f1_kwh_per_day": 0.81337, "loss_factor_f2_kwh_per_day": 0.0, "rejected_factor_f3_per_litre": 0.00011, "raw": ["017959", "000031", "0", "2021/Feb/15 13:01", "Vaillant", "Vaillant", "ecoFIT sustain 830", "VUW 306/6-3 (H-GB)", "47-044-72", "2016", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "18.3", "18.3", "", "", "88.7", "76.2", "", "75.8", "", "2", "", "", "104", "1", "2", "21", "2", "0", "", "", "0", "0", "", "", "", "", "2", "6.945", "0.085", "0.0115", "0.81337", "13.7495", "0.0981", "0.001", "0.0", "0.00011", "", "", "", "0045", "", "", "", "", "", "", "", "", "89.7", "97.8", "", "", "", "", "96.2"]} +{"pcdb_id": 17960, "brand_name": "Vaillant", "model_name": "ecoFIT sustain 835", "model_qualifier": "VUW 356/6-3 (H-GB)", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 76.4, "comparative_hot_water_efficiency_pct": 76.1, "output_kw_max": 18.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.0045, "loss_factor_f1_kwh_per_day": 0.83104, "loss_factor_f2_kwh_per_day": 0.0, "rejected_factor_f3_per_litre": 4e-05, "raw": ["017960", "000031", "0", "2020/Nov/17 08:33", "Vaillant", "Vaillant", "ecoFIT sustain 835", "VUW 356/6-3 (H-GB)", "47-044-73", "2016", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "18.3", "18.3", "", "", "88.7", "76.4", "", "76.1", "", "2", "", "", "104", "1", "2", "20", "2", "0", "", "", "", "0", "", "", "", "", "2", "6.921", "0.096", "0.0045", "0.83104", "13.751", "0.1246", "0.0005", "0.0", "0.00004", "", "", "", "0045", "", "", "", "", "", "", "", "", "89.7", "97.8", "", "", "", "", "96.2"]} +{"pcdb_id": 17962, "brand_name": "Vaillant", "model_name": "ecoFIT pure 412", "model_qualifier": "VU 126/6-3 OV (H-GB)", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 12.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017962", "000031", "0", "2017/Jul/17 09:51", "Vaillant", "Vaillant", "ecoFIT pure 412", "VU 126/6-3 OV (H-GB)", "41-694-08", "2016", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "12.3", "12.3", "", "", "89.1", "80.1", "", "58.5", "", "2", "", "", "102", "1", "2", "19", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0045", "", "", "", "", "", "", "", "", "89.3", "99.0", "", "", "", "", "97.2"]} +{"pcdb_id": 17963, "brand_name": "Vaillant", "model_name": "ecoFIT pure 415", "model_qualifier": "VU 156/6-3 OV (H-GB)", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 15.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017963", "000031", "0", "2017/Jul/17 09:52", "Vaillant", "Vaillant", "ecoFIT pure 415", "VU 156/6-3 OV (H-GB)", "41-694-09", "2016", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "15.3", "15.3", "", "", "89.1", "80.1", "", "58.5", "", "2", "", "", "102", "1", "2", "24", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0045", "", "", "", "", "", "", "", "", "89.1", "99.1", "", "", "", "", "97.2"]} +{"pcdb_id": 17964, "brand_name": "Vaillant", "model_name": "ecoFIT pure 418", "model_qualifier": "VU 186/6-3 OV (H-GB)", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 18.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017964", "000031", "0", "2017/Jul/17 09:52", "Vaillant", "Vaillant", "ecoFIT pure 418", "VU 186/6-3 OV (H-GB)", "41-694-10", "2016", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18.4", "18.4", "", "", "89.0", "80.0", "", "58.4", "", "2", "", "", "102", "1", "2", "25", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0045", "", "", "", "", "", "", "", "", "89.0", "98.9", "", "", "", "", "97.0"]} +{"pcdb_id": 17965, "brand_name": "Vaillant", "model_name": "ecoFIT pure 425", "model_qualifier": "VU 256/6-3 OV (H-GB)", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 30.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017965", "000031", "0", "2017/Jul/17 09:53", "Vaillant", "Vaillant", "ecoFIT pure 425", "VU 256/6-3 OV (H-GB)", "41-694-11", "2016", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "30.0", "30.0", "", "", "89.0", "80.0", "", "58.4", "", "2", "", "", "102", "1", "2", "29", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0045", "", "", "", "", "", "", "", "", "89.0", "98.8", "", "", "", "", "97.0"]} +{"pcdb_id": 17966, "brand_name": "Vaillant", "model_name": "ecoFIT pure 430", "model_qualifier": "VU 306/6-3 OV (H-GB)", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 25.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017966", "000031", "0", "2017/Jul/17 14:42", "Vaillant", "Vaillant", "ecoFIT pure 430", "VU 306/6-3 OV (H-GB)", "41-694-12", "2016", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "25.5", "25.5", "", "", "89.1", "80.1", "", "58.5", "", "2", "", "", "102", "1", "2", "37", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0045", "", "", "", "", "", "", "", "", "89.5", "99.0", "", "", "", "", "97.2"]} +{"pcdb_id": 17968, "brand_name": "Vaillant", "model_name": "ecoFIT pure 612", "model_qualifier": "VU 126/6-3 (H-GB)", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 12.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017968", "000031", "0", "2017/Jul/17 09:53", "Vaillant", "Vaillant", "ecoFIT pure 612", "VU 126/6-3 (H-GB)", "41-694-03", "2016", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "12.3", "12.3", "", "", "89.1", "80.1", "", "58.5", "", "2", "", "", "102", "1", "2", "19", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0045", "", "", "", "", "", "", "", "", "89.3", "99.0", "", "", "", "", "97.2"]} +{"pcdb_id": 17969, "brand_name": "Vaillant", "model_name": "ecoFIT pure 615", "model_qualifier": "VU 156/6-3 (H-GB)", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 15.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017969", "000031", "0", "2017/Jul/17 09:54", "Vaillant", "Vaillant", "ecoFIT pure 615", "VU 156/6-3 (H-GB)", "41-694-04", "2016", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "15.3", "15.3", "", "", "89.1", "80.1", "", "58.5", "", "2", "", "", "102", "1", "2", "24", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0045", "", "", "", "", "", "", "", "", "89.1", "99.1", "", "", "", "", "97.2"]} +{"pcdb_id": 17970, "brand_name": "Vaillant", "model_name": "ecoFIT pure 618", "model_qualifier": "VU 186/6-3 (H-GB)", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 18.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017970", "000031", "0", "2017/Jul/17 09:54", "Vaillant", "Vaillant", "ecoFIT pure 618", "VU 186/6-3 (H-GB)", "41-694-05", "2016", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18.4", "18.4", "", "", "89.0", "80.0", "", "58.4", "", "2", "", "", "102", "1", "2", "25", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0045", "", "", "", "", "", "", "", "", "89.0", "98.9", "", "", "", "", "97.0"]} +{"pcdb_id": 17971, "brand_name": "Vaillant", "model_name": "ecoFIT pure 625", "model_qualifier": "VU 256/6-3 (H-GB)", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 24.7, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017971", "000031", "0", "2017/Jul/17 09:54", "Vaillant", "Vaillant", "ecoFIT pure 625", "VU 256/6-3 (H-GB)", "41-694-08", "2016", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24.7", "24.7", "", "", "89.0", "80.0", "", "58.4", "", "2", "", "", "102", "1", "2", "29", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0045", "", "", "", "", "", "", "", "", "89.2", "98.8", "", "", "", "", "97.0"]} +{"pcdb_id": 17972, "brand_name": "Vaillant", "model_name": "ecoFIT pure 630", "model_qualifier": "VU 306/6-3 (H-GB)", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 25.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017972", "000031", "0", "2017/Jul/17 09:55", "Vaillant", "Vaillant", "ecoFIT pure 630", "VU 306/6-3 (H-GB)", "41-694-07", "2016", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "25.5", "25.5", "", "", "89.2", "80.2", "", "58.5", "", "2", "", "", "102", "1", "2", "37", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0045", "", "", "", "", "", "", "", "", "89.5", "99.1", "", "", "", "", "97.3"]} +{"pcdb_id": 17973, "brand_name": "Vaillant", "model_name": "ecoFIT pure 825", "model_qualifier": "VUW 256/6-3 (H-GB)", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.4, "comparative_hot_water_efficiency_pct": 56.5, "output_kw_max": 18.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017973", "000031", "0", "2017/Jul/17 09:55", "Vaillant", "Vaillant", "ecoFIT pure 825", "VUW 256/6-3 (H-GB)", "47-044-68", "2016", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "18.4", "18.4", "", "", "89.0", "80.4", "", "56.5", "", "2", "", "", "104", "1", "2", "25", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0045", "", "", "", "", "", "", "", "", "89.0", "98.9", "", "", "", "", "97.0"]} +{"pcdb_id": 17974, "brand_name": "Vaillant", "model_name": "ecoFIT pure 830", "model_qualifier": "VUW 306/6-3 (H-GB)", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.4, "comparative_hot_water_efficiency_pct": 56.5, "output_kw_max": 25.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017974", "000031", "0", "2017/Nov/01 12:27", "Vaillant", "Vaillant", "ecoFIT pure 830", "VUW 306/6-3 (H-GB)", "47-044-74", "2016", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "25.5", "25.5", "", "", "89.0", "80.4", "", "56.5", "", "2", "", "", "104", "1", "2", "29", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0045", "", "", "", "", "", "", "", "", "89.0", "98.8", "", "", "", "", "97.0"]} +{"pcdb_id": 17975, "brand_name": "Vaillant", "model_name": "ecoFIT pure 835", "model_qualifier": "VUW 356/6-3 (H-GB)", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 56.6, "output_kw_max": 25.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017975", "000031", "0", "2017/Jul/17 09:57", "Vaillant", "Vaillant", "ecoFIT pure 835", "VUW 356/6-3 (H-GB)", "47-044-70", "2016", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "25.5", "25.5", "", "", "89.1", "80.5", "", "56.6", "", "2", "", "", "104", "1", "2", "27", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0045", "", "", "", "", "", "", "", "", "89.5", "99.0", "", "", "", "", "97.2"]} +{"pcdb_id": 17976, "brand_name": "Vaillant", "model_name": "ecoTEC plus 412", "model_qualifier": "VU 126/6-5 OVZ (H-GB)", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 12.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017976", "000031", "0", "2018/Mar/12 08:57", "Vaillant", "Vaillant", "ecoTEC plus 412", "VU 126/6-5 OVZ (H-GB)", "41-694-13", "2016", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "12", "12", "", "", "89.1", "80.1", "", "58.5", "", "2", "", "", "102", "1", "2", "19", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0045", "", "", "", "", "", "", "", "", "89.3", "99.0", "", "", "", "", "97.2"]} +{"pcdb_id": 17977, "brand_name": "Vaillant", "model_name": "ecoTEC plus 415", "model_qualifier": "VU 156/6-5 OVZ (H-GB)", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 15.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017977", "000031", "0", "2018/Mar/12 08:58", "Vaillant", "Vaillant", "ecoTEC plus 415", "VU 156/6-5 OVZ (H-GB)", "41-694-14", "2016", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "15", "15", "", "", "89.1", "80.1", "", "58.5", "", "2", "", "", "102", "1", "2", "24", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0045", "", "", "", "", "", "", "", "", "89.1", "99.1", "", "", "", "", "97.2"]} +{"pcdb_id": 17978, "brand_name": "Vaillant", "model_name": "ecoTEC plus 418", "model_qualifier": "VU 186/6-5 OVZ (H-GB)", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 18.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017978", "000031", "0", "2018/Mar/12 08:58", "Vaillant", "Vaillant", "ecoTEC plus 418", "VU 186/6-5 OVZ (H-GB)", "41-694-15", "2016", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18", "18", "", "", "89.0", "80.0", "", "58.4", "", "2", "", "", "102", "1", "2", "25", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0045", "", "", "", "", "", "", "", "", "89.0", "98.9", "", "", "", "", "97.0"]} +{"pcdb_id": 17979, "brand_name": "Vaillant", "model_name": "ecoTEC plus 424", "model_qualifier": "VU 246/6-5 OVZ (H-GB)", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 25.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017979", "000031", "0", "2018/Mar/12 08:59", "Vaillant", "Vaillant", "ecoTEC plus 424", "VU 246/6-5 OVZ (H-GB)", "41-694-16", "2016", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "25", "25", "", "", "89.0", "80.0", "", "58.4", "", "2", "", "", "102", "1", "2", "29", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0045", "", "", "", "", "", "", "", "", "89.0", "98.9", "", "", "", "", "97.0"]} +{"pcdb_id": 17980, "brand_name": "Vaillant", "model_name": "ecoTEC plus 430", "model_qualifier": "VU 306/6-5 OVZ (H-GB)", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 25.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017980", "000031", "0", "2018/Mar/12 08:59", "Vaillant", "Vaillant", "ecoTEC plus 430", "VU 306/6-5 OVZ (H-GB)", "41-694-17", "2016", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "25", "25", "", "", "89.1", "80.1", "", "58.5", "", "2", "", "", "102", "1", "2", "37", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0045", "", "", "", "", "", "", "", "", "89.5", "99.0", "", "", "", "", "97.2"]} +{"pcdb_id": 17982, "brand_name": "Ideal", "model_name": "LOGIC COMBI", "model_qualifier": "C24", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 69.8, "output_kw_max": 24.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0026, "loss_factor_f1_kwh_per_day": 1.45745, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017982", "000008", "0", "2021/Apr/29 14:25", "Ideal Boilers", "Ideal", "LOGIC COMBI", "C24", "47-349-18", "2016", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "89.0", "87.3", "", "69.8", "", "2", "", "", "104", "1", "2", "29", "5", "0", "", "", "", "0", "", "", "", "", "1", "7.549", "0.076", "0.0026", "1.45745", "", "", "", "", "", "1", "0", "", "0035", "", "", "", "", "", "", "", "", "90.0", "98.6", "", "", "", "", "96.9"]} +{"pcdb_id": 17983, "brand_name": "Ideal", "model_name": "LOGIC COMBI", "model_qualifier": "C30", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 70.4, "output_kw_max": 24.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0026, "loss_factor_f1_kwh_per_day": 1.38721, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017983", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "LOGIC COMBI", "C30", "47-349-19", "2016", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "89.0", "87.3", "", "70.4", "", "2", "", "", "104", "1", "2", "31", "5", "0", "", "", "", "0", "", "", "", "", "1", "7.476", "0.075", "0.0026", "1.38721", "", "", "", "", "", "1", "0", "", "0025", "", "", "", "", "", "", "", "", "90.0", "98.6", "", "", "", "", "96.9"]} +{"pcdb_id": 17984, "brand_name": "Ideal", "model_name": "LOGIC COMBI", "model_qualifier": "C35", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 71.1, "output_kw_max": 24.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0025, "loss_factor_f1_kwh_per_day": 1.32349, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017984", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "LOGIC COMBI", "C35", "47-349-20", "2016", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "89.0", "87.3", "", "71.1", "", "2", "", "", "104", "1", "2", "42", "5", "0", "", "", "", "0", "", "", "", "", "1", "7.41", "0.074", "0.0025", "1.32349", "", "", "", "", "", "1", "0", "", "0025", "", "", "", "", "", "", "", "", "90.0", "98.6", "", "", "", "", "96.9"]} +{"pcdb_id": 17985, "brand_name": "Ideal", "model_name": "LOGIC + COMBI", "model_qualifier": "C24", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 69.8, "output_kw_max": 24.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0026, "loss_factor_f1_kwh_per_day": 1.45745, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017985", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "LOGIC + COMBI", "C24", "47-349-15", "2016", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "89.0", "87.3", "", "69.8", "", "2", "", "", "104", "1", "2", "29", "5", "0", "", "", "", "0", "", "", "", "", "1", "7.549", "0.076", "0.0026", "1.45745", "", "", "", "", "", "1", "0", "", "0035", "", "", "", "", "", "", "", "", "90.0", "98.6", "", "", "", "", "96.9"]} +{"pcdb_id": 17986, "brand_name": "Ideal", "model_name": "LOGIC + COMBI", "model_qualifier": "C30", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 70.4, "output_kw_max": 24.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0026, "loss_factor_f1_kwh_per_day": 1.38721, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017986", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "LOGIC + COMBI", "C30", "47-349-16", "2016", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "89.0", "87.3", "", "70.4", "", "2", "", "", "104", "1", "2", "31", "5", "0", "", "", "", "0", "", "", "", "", "1", "7.476", "0.075", "0.0026", "1.38721", "", "", "", "", "", "1", "0", "", "0035", "", "", "", "", "", "", "", "", "90.0", "98.6", "", "", "", "", "96.9"]} +{"pcdb_id": 17987, "brand_name": "Ideal", "model_name": "LOGIC + COMBI", "model_qualifier": "C35", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 71.1, "output_kw_max": 24.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0025, "loss_factor_f1_kwh_per_day": 1.32349, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017987", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "LOGIC + COMBI", "C35", "47-349-17", "2016", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "89.0", "87.3", "", "71.1", "", "2", "", "", "104", "1", "2", "42", "5", "0", "", "", "", "0", "", "", "", "", "1", "7.41", "0.074", "0.0025", "1.32349", "", "", "", "", "", "1", "0", "", "0035", "", "", "", "", "", "", "", "", "90.0", "98.6", "", "", "", "", "96.9"]} +{"pcdb_id": 17988, "brand_name": "Keston", "model_name": "COMBI C30", "model_qualifier": "", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 70.4, "output_kw_max": 24.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0026, "loss_factor_f1_kwh_per_day": 1.38721, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017988", "000022", "0", "2017/Feb/20 10:57", "Keston Boilers", "Keston", "COMBI C30", "", "47-930-07", "2016", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "89.0", "87.3", "", "70.4", "", "2", "", "", "104", "1", "2", "31", "5", "0", "", "", "", "0", "", "", "", "", "1", "7.476", "0.075", "0.0026", "1.38721", "", "", "", "", "", "1", "0", "", "0035", "", "", "", "", "", "", "", "", "90.0", "98.6", "", "", "", "", "96.9"]} +{"pcdb_id": 17990, "brand_name": "Keston", "model_name": "COMBI C35", "model_qualifier": "", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 71.1, "output_kw_max": 24.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0025, "loss_factor_f1_kwh_per_day": 1.32349, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017990", "000022", "0", "2017/Feb/20 10:57", "Keston Boilers", "Keston", "COMBI C35", "", "47-930-08", "2016", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "89.0", "87.3", "", "71.1", "", "2", "", "", "104", "1", "2", "42", "5", "0", "", "", "", "0", "", "", "", "", "1", "7.41", "0.074", "0.0025", "1.32349", "", "", "", "", "", "1", "0", "", "0035", "", "", "", "", "", "", "", "", "90.0", "98.6", "", "", "", "", "96.9"]} +{"pcdb_id": 17991, "brand_name": "Ideal", "model_name": "INDEPENDENT COMBI", "model_qualifier": "24", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 69.8, "output_kw_max": 24.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0026, "loss_factor_f1_kwh_per_day": 1.45745, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017991", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "INDEPENDENT COMBI", "24", "47-349-24", "2016", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "89.0", "87.3", "", "69.8", "", "2", "", "", "104", "1", "2", "29", "5", "0", "", "", "", "0", "", "", "", "", "1", "7.549", "0.076", "0.0026", "1.45745", "", "", "", "", "", "1", "0", "", "0025", "", "", "", "", "", "", "", "", "90.0", "98.6", "", "", "", "", "96.9"]} +{"pcdb_id": 17992, "brand_name": "Ideal", "model_name": "INDEPENDENT COMBI", "model_qualifier": "30", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 70.4, "output_kw_max": 24.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0026, "loss_factor_f1_kwh_per_day": 1.38721, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017992", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "INDEPENDENT COMBI", "30", "47-349-25", "2016", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "89.0", "87.3", "", "70.4", "", "2", "", "", "104", "1", "2", "31", "5", "0", "", "", "", "0", "", "", "", "", "1", "7.476", "0.075", "0.0026", "1.38721", "", "", "", "", "", "1", "0", "", "0025", "", "", "", "", "", "", "", "", "90.0", "98.6", "", "", "", "", "96.9"]} +{"pcdb_id": 17993, "brand_name": "Ideal", "model_name": "INDEPENDENT COMBI", "model_qualifier": "35", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 71.1, "output_kw_max": 24.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0025, "loss_factor_f1_kwh_per_day": 1.32349, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017993", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "INDEPENDENT COMBI", "35", "47-349-26", "2016", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "89.0", "87.3", "", "71.1", "", "2", "", "", "104", "1", "2", "42", "5", "0", "", "", "", "0", "", "", "", "", "1", "7.41", "0.074", "0.0025", "1.32349", "", "", "", "", "", "1", "0", "", "0025", "", "", "", "", "", "", "", "", "90.0", "98.6", "", "", "", "", "96.9"]} +{"pcdb_id": 17994, "brand_name": "Ideal", "model_name": "INDEPENDENT + COMBI", "model_qualifier": "24", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 69.8, "output_kw_max": 24.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0026, "loss_factor_f1_kwh_per_day": 1.45745, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017994", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "INDEPENDENT + COMBI", "24", "47-349-27", "2016", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "89.0", "87.3", "", "69.8", "", "2", "", "", "104", "1", "2", "29", "5", "0", "", "", "", "0", "", "", "", "", "1", "7.549", "0.076", "0.0026", "1.45745", "", "", "", "", "", "1", "0", "", "0025", "", "", "", "", "", "", "", "", "90.0", "98.6", "", "", "", "", "96.9"]} +{"pcdb_id": 17995, "brand_name": "Ideal", "model_name": "INDEPENDENT + COMBI", "model_qualifier": "30", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 70.4, "output_kw_max": 24.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0026, "loss_factor_f1_kwh_per_day": 1.38721, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017995", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "INDEPENDENT + COMBI", "30", "47-349-28", "2016", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "89.0", "87.3", "", "70.4", "", "2", "", "", "104", "1", "2", "31", "5", "0", "", "", "", "0", "", "", "", "", "1", "7.476", "0.075", "0.0026", "1.38721", "", "", "", "", "", "1", "0", "", "0025", "", "", "", "", "", "", "", "", "90.0", "98.6", "", "", "", "", "96.9"]} +{"pcdb_id": 17996, "brand_name": "Ideal", "model_name": "INDEPENDENT + COMBI", "model_qualifier": "35", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 71.1, "output_kw_max": 24.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0025, "loss_factor_f1_kwh_per_day": 1.32349, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017996", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "INDEPENDENT + COMBI", "35", "47-349-29", "2016", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "89.0", "87.3", "", "71.1", "", "2", "", "", "104", "1", "2", "42", "5", "0", "", "", "", "0", "", "", "", "", "1", "7.41", "0.074", "0.0025", "1.32349", "", "", "", "", "", "1", "0", "", "0025", "", "", "", "", "", "", "", "", "90.0", "98.6", "", "", "", "", "96.9"]} +{"pcdb_id": 17997, "brand_name": "i-mini", "model_name": "C24", "model_qualifier": "", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 69.8, "output_kw_max": 24.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0026, "loss_factor_f1_kwh_per_day": 1.45745, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017997", "000008", "0", "2016/Nov/14 12:38", "Ideal Boilers", "i-mini", "C24", "", "47-349-30", "2016", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "89.0", "87.3", "", "69.8", "", "2", "", "", "104", "1", "2", "29", "5", "0", "", "", "", "0", "", "", "", "", "1", "7.549", "0.076", "0.0026", "1.45745", "", "", "", "", "", "1", "0", "", "0025", "", "", "", "", "", "", "", "", "90.0", "98.6", "", "", "", "", "96.9"]} +{"pcdb_id": 17998, "brand_name": "i-mini", "model_name": "C30", "model_qualifier": "", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 70.4, "output_kw_max": 24.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0026, "loss_factor_f1_kwh_per_day": 1.38721, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017998", "000008", "0", "2016/Nov/14 12:38", "Ideal Boilers", "i-mini", "C30", "", "47-349-31", "2016", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "89.0", "87.3", "", "70.4", "", "2", "", "", "104", "1", "2", "31", "5", "0", "", "", "0", "0", "", "", "", "", "1", "7.476", "0.075", "0.0026", "1.38721", "", "", "", "", "", "1", "0", "", "0025", "", "", "", "", "", "", "", "", "90.0", "98.6", "", "", "", "", "96.9"]} +{"pcdb_id": 17999, "brand_name": "Glow-worm", "model_name": "EASICOM 3 25r", "model_qualifier": "", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 25.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["017999", "000207", "0", "2019/May/09 11:49", "Glow-worm", "Glow-worm", "EASICOM 3 25r", "", "41-019-50", "2016", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "25.2", "25.2", "", "", "89.0", "80.0", "", "58.4", "", "2", "", "", "102", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0085", "", "", "", "", "", "", "", "", "89.0", "98.8", "", "", "", "", "97.0"]} +{"pcdb_id": 18000, "brand_name": "Glow-worm", "model_name": "EASICOM 3 25s", "model_qualifier": "", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 25.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018000", "000207", "0", "2019/May/09 11:53", "Glow-worm", "Glow-worm", "EASICOM 3 25s", "", "41-019-49", "2016", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "25.2", "25.2", "", "", "89.0", "80.0", "", "58.4", "", "2", "", "", "102", "1", "2", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0085", "", "", "", "", "", "", "", "", "89.2", "98.8", "", "", "", "", "97.0"]} +{"pcdb_id": 18001, "brand_name": "Glow-worm", "model_name": "PROCOMBI ESSENTIAL", "model_qualifier": "24c P - A (H-GB)", "winter_efficiency_pct": 90.5, "summer_efficiency_pct": 81.9, "comparative_hot_water_efficiency_pct": 57.6, "output_kw_max": 24.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018001", "000207", "0", "2017/Jun/12 09:17", "Glow-worm", "Glow-worm", "PROCOMBI ESSENTIAL", "24c P - A (H-GB)", "47-019-46", "2016", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "90.5", "81.9", "", "57.6", "", "2", "0", "", "104", "1", "2", "", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.4", "100.2", "", "", "", "", "98.3"]} +{"pcdb_id": 18002, "brand_name": "Glow-worm", "model_name": "PROCOMBI ESSENTIAL 35c", "model_qualifier": "", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 56.6, "output_kw_max": 35.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018002", "000207", "0", "2017/Jul/17 09:58", "Glow-worm", "Glow-worm", "PROCOMBI ESSENTIAL 35c", "", "47-019-49", "2016", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "35.0", "35.0", "", "", "89.1", "80.5", "", "56.6", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.5", "99.0", "", "", "", "", "97.2"]} +{"pcdb_id": 18004, "brand_name": "Sime", "model_name": "MURELLE ADVANCED HE 30 MkII", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 86.8, "comparative_hot_water_efficiency_pct": 69.0, "output_kw_max": 23.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0058, "loss_factor_f1_kwh_per_day": 1.47541, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018004", "000213", "0", "2016/Nov/02 16:28", "Fonderie Sime S.p.A.", "Sime", "MURELLE ADVANCED HE 30 MkII", "", "47-283-82", "2017", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "23.6", "23.6", "", "", "88.4", "86.8", "", "69.0", "", "2", "", "", "104", "1", "2", "44", "3", "0", "", "", "", "0", "", "", "", "", "1", "7.63", "0.118", "0.0058", "1.47541", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.5", "97.7", "", "", "", "", "95.9"]} +{"pcdb_id": 18005, "brand_name": "Sime", "model_name": "MURELLE ADVANCED HE 40 MkII", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 86.9, "comparative_hot_water_efficiency_pct": 65.8, "output_kw_max": 34.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0056, "loss_factor_f1_kwh_per_day": 1.83882, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018005", "000213", "0", "2016/Nov/02 16:28", "Fonderie Sime S.p.A.", "Sime", "MURELLE ADVANCED HE 40 MkII", "", "47-283-83", "2017", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "34.5", "34.5", "", "", "88.5", "86.9", "", "65.8", "", "2", "", "", "104", "1", "2", "66", "3", "0", "", "", "", "0", "", "", "", "", "1", "7.998", "0.108", "0.0056", "1.83882", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.7", "97.7", "", "", "", "", "96.0"]} +{"pcdb_id": 18006, "brand_name": "Sime", "model_name": "MURELLE PRO HE 30 MkII", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 86.8, "comparative_hot_water_efficiency_pct": 73.2, "output_kw_max": 23.6, "final_year_of_manufacture": 2019, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0051, "loss_factor_f1_kwh_per_day": 1.05541, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018006", "000213", "0", "2019/Feb/28 13:17", "Fonderie Sime S.p.A.", "Sime", "MURELLE PRO HE 30 MkII", "", "47-283-81", "2017", "2019", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "23.6", "23.6", "", "", "88.4", "86.8", "", "73.2", "", "2", "", "", "104", "1", "2", "44", "3", "0", "", "", "", "0", "", "", "", "", "1", "7.19", "0.115", "0.0051", "1.05541", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.5", "97.7", "", "", "", "", "95.9"]} +{"pcdb_id": 18007, "brand_name": "Sime", "model_name": "MURELLE PRO HE 20 R MkII", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 19.7, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018007", "000213", "0", "2016/Nov/02 16:27", "Fonderie Sime S.p.A.", "Sime", "MURELLE PRO HE 20 R MkII", "", "41-283-61", "2017", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "19.7", "19.7", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "24", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.5", "97.7", "", "", "", "", "95.9"]} +{"pcdb_id": 18008, "brand_name": "Sime", "model_name": "MURELLE PRO HE 30 R MkII", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 29.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018008", "000213", "0", "2016/Nov/02 16:29", "Fonderie Sime S.p.A.", "Sime", "MURELLE PRO HE 30 R MkII", "", "41-283-62", "2017", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "29.5", "29.5", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "37", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.5", "97.7", "", "", "", "", "95.9"]} +{"pcdb_id": 18009, "brand_name": "Sime", "model_name": "MURELLE PRO HE 25 HO MkII", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 23.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018009", "000213", "0", "2016/Nov/02 16:30", "Fonderie Sime S.p.A.", "Sime", "MURELLE PRO HE 25 HO MkII", "", "41-283-63", "2017", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "23.6", "23.6", "", "", "88.5", "79.5", "", "58.0", "", "2", "", "", "102", "1", "2", "34", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.7", "97.7", "", "", "", "", "96.0"]} +{"pcdb_id": 18011, "brand_name": "Firebird", "model_name": "Enviromax Slimline Combi", "model_qualifier": "20", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 82.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 20.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018011", "000047", "0", "2017/Jan/25 15:41", "Firebird Heating Solutions Ltd", "Firebird", "Enviromax Slimline Combi", "20", "", "2009", "current", "4", "1", "1", "2", "0", "", "", "2", "2", "2", "20.0", "20.0", "", "", "89.4", "82.0", "", "57.7", "", "2", "", "", "202", "1", "1", "", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "93.1", "97.4", "", "", "", "", "96.6"]} +{"pcdb_id": 18012, "brand_name": "Firebird", "model_name": "Enviromax Slimline Combi", "model_qualifier": "26", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 82.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 26.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018012", "000047", "0", "2017/Jan/25 15:42", "Firebird Heating Solutions Ltd", "Firebird", "Enviromax Slimline Combi", "26", "", "2009", "current", "4", "1", "1", "2", "0", "", "", "2", "2", "2", "26.0", "26.0", "", "", "89.4", "82.0", "", "57.7", "", "2", "", "", "202", "1", "1", "", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "93.0", "97.5", "", "", "", "", "96.7"]} +{"pcdb_id": 18013, "brand_name": "Viessmann", "model_name": "VITODENS 200-W", "model_qualifier": "B2HB-19", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 17.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018013", "000033", "0", "2017/Jul/17 11:21", "Viessmann", "Viessmann", "VITODENS 200-W", "B2HB-19", "", "2016", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "17.6", "17.6", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "16", "4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "2005", "", "", "", "", "", "", "", "", "87.8", "97.8", "", "", "", "", "95.9"]} +{"pcdb_id": 18014, "brand_name": "Viessmann", "model_name": "VITODENS 200-W", "model_qualifier": "B2HB-26", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 24.1, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018014", "000033", "0", "2017/Jul/26 09:04", "Viessmann", "Viessmann", "VITODENS 200-W", "B2HB-26", "", "2016", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24.1", "24.1", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "18", "4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "2005", "", "", "", "", "", "", "", "", "88.3", "97.8", "", "", "", "", "96.0"]} +{"pcdb_id": 18015, "brand_name": "Viessmann", "model_name": "VITODENS 200-W", "model_qualifier": "B2HB-30", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 28.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018015", "000033", "0", "2017/Jul/17 11:22", "Viessmann", "Viessmann", "VITODENS 200-W", "B2HB-30", "", "2016", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "28.0", "28.0", "", "", "88.5", "79.5", "", "58.0", "", "2", "", "", "102", "1", "2", "20", "4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "2005", "", "", "", "", "", "", "", "", "88.3", "97.8", "", "", "", "", "96.0"]} +{"pcdb_id": 18016, "brand_name": "Viessmann", "model_name": "VITODENS 200-W", "model_qualifier": "B2HB-35", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 32.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018016", "000033", "0", "2017/Jul/17 11:22", "Viessmann", "Viessmann", "VITODENS 200-W", "B2HB-35", "", "2016", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "32.5", "32.5", "", "", "88.5", "79.5", "", "58.1", "", "2", "", "", "102", "1", "2", "22", "4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "2005", "", "", "", "", "", "", "", "", "88.0", "98.0", "", "", "", "", "96.1"]} +{"pcdb_id": 18017, "brand_name": "Viessmann", "model_name": "VITODENS 200-W", "model_qualifier": "B2KB-26", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 56.1, "output_kw_max": 24.1, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018017", "000033", "0", "2017/Jul/17 11:22", "Viessmann", "Viessmann", "VITODENS 200-W", "B2KB-26", "", "2016", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.1", "24.1", "", "", "88.4", "79.8", "", "56.1", "", "2", "", "", "104", "1", "2", "18", "4", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "2005", "", "", "", "", "", "", "", "", "88.3", "97.8", "", "", "", "", "96.0"]} +{"pcdb_id": 18019, "brand_name": "Viessmann", "model_name": "VITODENS 200-W", "model_qualifier": "B2KB-30", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 56.2, "output_kw_max": 28.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018019", "000033", "0", "2017/Jul/17 11:22", "Viessmann", "Viessmann", "VITODENS 200-W", "B2KB-30", "", "2016", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28.0", "28.0", "", "", "88.4", "79.8", "", "56.2", "", "2", "", "", "104", "1", "2", "20", "4", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "2005", "", "", "", "", "", "", "", "", "88.2", "97.8", "", "", "", "", "96.0"]} +{"pcdb_id": 18020, "brand_name": "Viessmann", "model_name": "VITODENS 200-W", "model_qualifier": "B2KB-35", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 56.2, "output_kw_max": 32.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018020", "000033", "0", "2017/Jul/17 11:23", "Viessmann", "Viessmann", "VITODENS 200-W", "B2KB-35", "", "2016", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "32.5", "32.5", "", "", "88.5", "79.9", "", "56.2", "", "2", "", "", "104", "1", "2", "22", "4", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "2005", "", "", "", "", "", "", "", "", "88.0", "98.0", "", "", "", "", "96.1"]} +{"pcdb_id": 18027, "brand_name": "Ideal", "model_name": "INDEPENDENT SYSTEM", "model_qualifier": "s15", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 15.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018027", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "INDEPENDENT SYSTEM", "s15", "41-750-69", "2016", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "15.0", "15.0", "", "", "88.7", "79.7", "", "58.2", "", "2", "", "", "102", "1", "2", "48", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "90.0", "97.8", "", "", "", "", "96.4"]} +{"pcdb_id": 18028, "brand_name": "Ideal", "model_name": "INDEPENDENT SYSTEM", "model_qualifier": "s18", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 18.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018028", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "INDEPENDENT SYSTEM", "s18", "41-750-70", "2016", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18.0", "18.0", "", "", "88.9", "79.9", "", "58.4", "", "2", "", "", "102", "1", "2", "26", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "89.7", "98.5", "", "", "", "", "96.8"]} +{"pcdb_id": 18029, "brand_name": "Ideal", "model_name": "INDEPENDENT SYSTEM", "model_qualifier": "s24", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 24.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018029", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "INDEPENDENT SYSTEM", "s24", "41-750-71", "2016", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "89.1", "80.1", "", "58.5", "", "2", "", "", "102", "1", "2", "42", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "90.0", "98.7", "", "", "", "", "97.0"]} +{"pcdb_id": 18030, "brand_name": "Ideal", "model_name": "INDEPENDENT SYSTEM", "model_qualifier": "s30", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 30.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018030", "000008", "0", "2017/May/15 15:31", "Ideal Boilers", "Ideal", "INDEPENDENT SYSTEM", "s30", "41-750-72", "2016", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "30.3", "30.3", "", "", "88.8", "79.8", "", "58.3", "", "2", "", "", "102", "1", "2", "48", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "89.6", "98.2", "", "", "", "", "96.6"]} +{"pcdb_id": 18031, "brand_name": "Ideal", "model_name": "LOGIC+ HEAT", "model_qualifier": "H12", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 12.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018031", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "LOGIC+ HEAT", "H12", "41-750-82", "2016", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "12.0", "12.0", "", "", "88.7", "79.7", "", "58.2", "", "2", "", "", "102", "1", "2", "20", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "89.9", "97.7", "", "", "", "", "96.2"]} +{"pcdb_id": 18032, "brand_name": "Ideal", "model_name": "LOGIC+ HEAT", "model_qualifier": "H15", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 15.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018032", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "LOGIC+ HEAT", "H15", "41-750-83", "2016", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "15.0", "15.0", "", "", "88.7", "79.7", "", "58.2", "", "2", "", "", "102", "1", "2", "26", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "90.0", "97.8", "", "", "", "", "96.3"]} +{"pcdb_id": 18033, "brand_name": "Ideal", "model_name": "LOGIC+ HEAT", "model_qualifier": "H18", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 18.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018033", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "LOGIC+ HEAT", "H18", "41-750-84", "2016", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18.0", "18.0", "", "", "88.9", "79.9", "", "58.4", "", "2", "", "", "102", "1", "2", "26", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "89.7", "98.5", "", "", "", "", "96.8"]} +{"pcdb_id": 18034, "brand_name": "Ideal", "model_name": "LOGIC+ HEAT", "model_qualifier": "H24", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 24.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018034", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "LOGIC+ HEAT", "H24", "41-750-85", "2016", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "89.1", "80.1", "", "58.5", "", "2", "", "", "102", "1", "2", "48", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "90.0", "98.7", "", "", "", "", "97.0"]} +{"pcdb_id": 18035, "brand_name": "Ideal", "model_name": "LOGIC+ HEAT", "model_qualifier": "H30", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 30.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018035", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "LOGIC+ HEAT", "H30", "41-750-86", "2016", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "30.3", "30.3", "", "", "88.8", "79.8", "", "58.3", "", "2", "", "", "102", "1", "2", "48", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "89.6", "98.2", "", "", "", "", "96.6"]} +{"pcdb_id": 18036, "brand_name": "Ideal", "model_name": "LOGIC+ SYSTEM", "model_qualifier": "s15", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 15.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018036", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "LOGIC+ SYSTEM", "s15", "41-750-85", "2016", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "15.0", "15.0", "", "", "88.7", "79.7", "", "58.2", "", "2", "", "", "102", "1", "2", "21", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "90.0", "97.8", "", "", "", "", "96.3"]} +{"pcdb_id": 18037, "brand_name": "Ideal", "model_name": "LOGIC+ SYSTEM", "model_qualifier": "s18", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 18.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018037", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "LOGIC+ SYSTEM", "s18", "41-750-66", "2016", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18.0", "18.0", "", "", "88.9", "79.9", "", "58.4", "", "2", "", "", "102", "1", "2", "26", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "89.7", "98.5", "", "", "", "", "96.8"]} +{"pcdb_id": 18038, "brand_name": "Ideal", "model_name": "LOGIC+ SYSTEM", "model_qualifier": "s24", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 24.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018038", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "LOGIC+ SYSTEM", "s24", "41-750-67", "2016", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "89.1", "80.1", "", "58.5", "", "2", "", "", "102", "1", "2", "42", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "90.0", "98.7", "", "", "", "", "97.0"]} +{"pcdb_id": 18039, "brand_name": "Ideal", "model_name": "LOGIC+ SYSTEM", "model_qualifier": "s30", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 30.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018039", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "LOGIC+ SYSTEM", "s30", "41-750-68", "2016", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "30.3", "30.3", "", "", "88.8", "79.8", "", "58.3", "", "2", "", "", "102", "1", "2", "48", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "89.6", "98.2", "", "", "", "", "96.6"]} +{"pcdb_id": 18040, "brand_name": "Ideal", "model_name": "LOGIC HEAT", "model_qualifier": "H12", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 12.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018040", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "LOGIC HEAT", "H12", "41-750-77", "2016", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "12.0", "12.0", "", "", "88.7", "79.7", "", "58.2", "", "2", "", "", "102", "1", "2", "20", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "89.9", "97.7", "", "", "", "", "96.2"]} +{"pcdb_id": 18041, "brand_name": "Ideal", "model_name": "LOGIC HEAT", "model_qualifier": "H15", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 15.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018041", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "LOGIC HEAT", "H15", "41-750-78", "2016", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "15.0", "15.0", "", "", "88.7", "79.7", "", "58.2", "", "2", "", "", "102", "1", "2", "21", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "90.0", "97.8", "", "", "", "", "96.3"]} +{"pcdb_id": 18042, "brand_name": "Ideal", "model_name": "LOGIC HEAT", "model_qualifier": "H18", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 18.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018042", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "LOGIC HEAT", "H18", "41-750-79", "2016", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18.0", "18.0", "", "", "88.9", "79.9", "", "58.4", "", "2", "", "", "102", "1", "2", "26", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "89.7", "98.5", "", "", "", "", "96.8"]} +{"pcdb_id": 18043, "brand_name": "Ideal", "model_name": "LOGIC HEAT", "model_qualifier": "H24", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 24.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018043", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "LOGIC HEAT", "H24", "41-750-80", "2016", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "89.1", "80.1", "", "58.5", "", "2", "", "", "102", "1", "2", "42", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "90.0", "98.7", "", "", "", "", "97.0"]} +{"pcdb_id": 18044, "brand_name": "Ideal", "model_name": "LOGIC HEAT", "model_qualifier": "H30", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 30.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018044", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "LOGIC HEAT", "H30", "41-750-81", "2016", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "30.3", "30.3", "", "", "88.8", "79.8", "", "58.3", "", "2", "", "", "102", "1", "2", "48", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "89.6", "98.2", "", "", "", "", "96.6"]} +{"pcdb_id": 18045, "brand_name": "Ideal", "model_name": "LOGIC SYSTEM", "model_qualifier": "s15", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 15.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018045", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "LOGIC SYSTEM", "s15", "41-750-61", "2016", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "15.0", "15.0", "", "", "88.7", "79.7", "", "58.2", "", "2", "", "", "102", "1", "2", "21", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "90.0", "97.8", "", "", "", "", "96.3"]} +{"pcdb_id": 18046, "brand_name": "Ideal", "model_name": "LOGIC SYSTEM", "model_qualifier": "s15IE", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 15.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018046", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "LOGIC SYSTEM", "s15IE", "41-750-73", "2016", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "15.0", "15.0", "", "", "88.7", "79.7", "", "58.2", "", "2", "", "", "102", "1", "2", "21", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "90.0", "97.8", "", "", "", "", "96.3"]} +{"pcdb_id": 18047, "brand_name": "Ideal", "model_name": "LOGIC SYSTEM", "model_qualifier": "s18", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 18.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018047", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "LOGIC SYSTEM", "s18", "41-750-62", "2016", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18.0", "18.0", "", "", "88.9", "79.9", "", "58.4", "", "2", "", "", "102", "1", "2", "26", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "89.7", "98.5", "", "", "", "", "96.8"]} +{"pcdb_id": 18048, "brand_name": "Ideal", "model_name": "LOGIC SYSTEM", "model_qualifier": "s18IE", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 18.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018048", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "LOGIC SYSTEM", "s18IE", "41-750-74", "2016", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18.0", "18.0", "", "", "88.9", "79.9", "", "58.4", "", "2", "", "", "102", "1", "2", "26", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "89.7", "98.5", "", "", "", "", "96.8"]} +{"pcdb_id": 18049, "brand_name": "Ideal", "model_name": "LOGIC SYSTEM", "model_qualifier": "s24", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 24.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018049", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "LOGIC SYSTEM", "s24", "41-750-63", "2016", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "89.1", "80.1", "", "58.5", "", "2", "", "", "102", "1", "2", "42", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "90.0", "98.7", "", "", "", "", "97.0"]} +{"pcdb_id": 18050, "brand_name": "Ideal", "model_name": "LOGIC SYSTEM", "model_qualifier": "s24IE", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 24.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018050", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "LOGIC SYSTEM", "s24IE", "41-750-75", "2016", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "89.1", "80.1", "", "58.5", "", "2", "", "", "102", "1", "2", "42", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "90.0", "98.7", "", "", "", "", "97.0"]} +{"pcdb_id": 18051, "brand_name": "Ideal", "model_name": "LOGIC SYSTEM", "model_qualifier": "s30", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 30.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018051", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "LOGIC SYSTEM", "s30", "41-750-64", "2016", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "30.3", "30.3", "", "", "88.8", "79.8", "", "58.3", "", "2", "", "", "102", "1", "2", "48", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "89.6", "98.2", "", "", "", "", "96.6"]} +{"pcdb_id": 18052, "brand_name": "Ideal", "model_name": "LOGIC SYSTEM", "model_qualifier": "s30IE", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 30.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018052", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "LOGIC SYSTEM", "s30IE", "41-750-76", "2016", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "30.3", "30.3", "", "", "88.8", "79.8", "", "58.3", "", "2", "", "", "102", "1", "2", "48", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "89.6", "98.2", "", "", "", "", "96.6"]} +{"pcdb_id": 18053, "brand_name": "Keston", "model_name": "KESTON SYSTEM S30", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 30.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018053", "000022", "0", "2017/May/15 15:31", "Keston Boilers", "Keston", "KESTON SYSTEM S30", "", "41-930-45", "2016", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "30.3", "30.3", "", "", "88.8", "79.8", "", "58.3", "", "2", "", "", "102", "1", "2", "48", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "", "", "", "", "89.6", "98.2", "", "", "", "", "96.6"]} +{"pcdb_id": 18054, "brand_name": "Ideal", "model_name": "INDEPENDENT + COMBI 30P", "model_qualifier": "", "winter_efficiency_pct": 90.1, "summer_efficiency_pct": 81.5, "comparative_hot_water_efficiency_pct": 57.3, "output_kw_max": 24.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018054", "000008", "0", "2017/Jan/23 13:46", "Ideal Boilers", "Ideal", "INDEPENDENT + COMBI 30P", "", "47-349-28", "2016", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "90.1", "81.5", "", "57.3", "", "2", "1", "", "104", "1", "2", "31", "5", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "", "", "", "", "92.0", "100.8", "", "", "", "", "99.2"]} +{"pcdb_id": 18055, "brand_name": "Ideal", "model_name": "INDEPENDENT COMBI", "model_qualifier": "30P", "winter_efficiency_pct": 90.1, "summer_efficiency_pct": 81.5, "comparative_hot_water_efficiency_pct": 57.3, "output_kw_max": 24.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018055", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "INDEPENDENT COMBI", "30P", "47-349-25", "2016", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "90.1", "81.5", "", "57.3", "", "2", "1", "", "104", "1", "2", "31", "5", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "", "", "", "", "92.0", "100.8", "", "", "", "", "99.2"]} +{"pcdb_id": 18056, "brand_name": "Ideal", "model_name": "INDEPENDENT SYSTEM S30P", "model_qualifier": "", "winter_efficiency_pct": 89.8, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 59.1, "output_kw_max": 30.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018056", "000008", "0", "2017/May/15 15:31", "Ideal Boilers", "Ideal", "INDEPENDENT SYSTEM S30P", "", "41-750-72", "2016", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "30.3", "30.3", "", "", "89.8", "80.8", "", "59.1", "", "2", "1", "", "102", "1", "2", "48", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0015", "", "", "", "", "", "", "", "", "91.6", "100.4", "", "", "", "", "98.7"]} +{"pcdb_id": 18057, "brand_name": "Ideal", "model_name": "LOGIC + COMBI C30P", "model_qualifier": "", "winter_efficiency_pct": 90.1, "summer_efficiency_pct": 81.5, "comparative_hot_water_efficiency_pct": 57.3, "output_kw_max": 24.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018057", "000008", "0", "2017/Jan/23 13:46", "Ideal Boilers", "Ideal", "LOGIC + COMBI C30P", "", "47-349-16", "2016", "current", "2", "1", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "90.1", "81.5", "", "57.3", "", "2", "1", "", "104", "1", "2", "31", "5", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "", "", "", "", "92.0", "100.8", "", "", "", "", "99.2"]} +{"pcdb_id": 18058, "brand_name": "Ideal", "model_name": "LOGIC + HEAT H30P", "model_qualifier": "", "winter_efficiency_pct": 89.8, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 59.1, "output_kw_max": 30.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018058", "000008", "0", "2017/May/15 15:31", "Ideal Boilers", "Ideal", "LOGIC + HEAT H30P", "", "41-750-86", "2016", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "30.3", "30.3", "", "", "89.8", "80.8", "", "59.1", "", "2", "1", "", "102", "1", "2", "48", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0015", "", "", "", "", "", "", "", "", "91.6", "100.4", "", "", "", "", "98.7"]} +{"pcdb_id": 18059, "brand_name": "Ideal", "model_name": "LOGIC + SYSTEM S30P", "model_qualifier": "", "winter_efficiency_pct": 89.8, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 59.1, "output_kw_max": 30.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018059", "000008", "0", "2017/May/15 15:31", "Ideal Boilers", "Ideal", "LOGIC + SYSTEM S30P", "", "41-750-68", "2016", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "30.3", "30.3", "", "", "89.8", "80.8", "", "59.1", "", "2", "1", "", "102", "1", "2", "48", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0015", "", "", "", "", "", "", "", "", "91.6", "100.4", "", "", "", "", "98.7"]} +{"pcdb_id": 18060, "brand_name": "Ideal", "model_name": "LOGIC COMBI", "model_qualifier": "ESP1 35P", "winter_efficiency_pct": 90.1, "summer_efficiency_pct": 81.5, "comparative_hot_water_efficiency_pct": 57.3, "output_kw_max": 24.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018060", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "LOGIC COMBI", "ESP1 35P", "47-349-23", "2016", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "90.1", "81.5", "", "57.3", "", "2", "1", "", "104", "1", "2", "42", "5", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "", "", "", "", "92.0", "100.8", "", "", "", "", "99.2"]} +{"pcdb_id": 18061, "brand_name": "Ideal", "model_name": "LOGIC HEAT H30P", "model_qualifier": "", "winter_efficiency_pct": 89.8, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 59.1, "output_kw_max": 30.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018061", "000008", "0", "2017/May/15 15:31", "Ideal Boilers", "Ideal", "LOGIC HEAT H30P", "", "41-750-81", "2016", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "30.3", "30.3", "", "", "89.8", "80.8", "", "59.1", "", "2", "1", "", "102", "1", "2", "48", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0015", "", "", "", "", "", "", "", "", "91.6", "100.4", "", "", "", "", "98.7"]} +{"pcdb_id": 18062, "brand_name": "Ideal", "model_name": "LOGIC SYSTEM S24P IE", "model_qualifier": "", "winter_efficiency_pct": 90.1, "summer_efficiency_pct": 81.1, "comparative_hot_water_efficiency_pct": 59.2, "output_kw_max": 24.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018062", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "LOGIC SYSTEM S24P IE", "", "41-750-75", "2016", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "90.1", "81.1", "", "59.2", "", "2", "1", "", "102", "1", "2", "42", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "92.0", "100.8", "", "", "", "", "99.2"]} +{"pcdb_id": 18063, "brand_name": "Ideal", "model_name": "LOGIC SYSTEM S30P IE", "model_qualifier": "", "winter_efficiency_pct": 89.8, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 59.1, "output_kw_max": 30.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018063", "000008", "0", "2017/May/15 15:31", "Ideal Boilers", "Ideal", "LOGIC SYSTEM S30P IE", "", "41-750-76", "2016", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "30.3", "30.3", "", "", "89.8", "80.8", "", "59.1", "", "2", "1", "", "102", "1", "2", "48", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0015", "", "", "", "", "", "", "", "", "91.6", "100.4", "", "", "", "", "98.7"]} +{"pcdb_id": 18064, "brand_name": "Ideal", "model_name": "LOGIC SYSTEM S30P", "model_qualifier": "", "winter_efficiency_pct": 89.8, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 59.1, "output_kw_max": 30.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018064", "000008", "0", "2017/May/15 15:31", "Ideal Boilers", "Ideal", "LOGIC SYSTEM S30P", "", "41-750-64", "2016", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "30.3", "30.3", "", "", "89.8", "80.8", "", "59.1", "", "2", "1", "", "102", "1", "2", "48", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0015", "", "", "", "", "", "", "", "", "91.6", "100.4", "", "", "", "", "98.7"]} +{"pcdb_id": 18065, "brand_name": "Ideal", "model_name": "LOGIC COMBI C24P", "model_qualifier": "", "winter_efficiency_pct": 90.1, "summer_efficiency_pct": 81.5, "comparative_hot_water_efficiency_pct": 57.3, "output_kw_max": 24.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018065", "000008", "0", "2017/Jan/23 13:46", "Ideal Boilers", "Ideal", "LOGIC COMBI C24P", "", "47-349-18", "2016", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "90.1", "81.5", "", "57.3", "", "2", "1", "", "104", "1", "2", "29", "5", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "", "", "", "", "92.0", "100.8", "", "", "", "", "99.2"]} +{"pcdb_id": 18066, "brand_name": "Ideal", "model_name": "LOGIC COMBI C30P", "model_qualifier": "", "winter_efficiency_pct": 90.1, "summer_efficiency_pct": 81.5, "comparative_hot_water_efficiency_pct": 57.3, "output_kw_max": 24.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018066", "000008", "0", "2017/Jan/23 13:46", "Ideal Boilers", "Ideal", "LOGIC COMBI C30P", "", "47-349-19", "2016", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "90.1", "81.5", "", "57.3", "", "2", "1", "", "104", "1", "2", "31", "5", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "", "", "", "", "92.0", "100.8", "", "", "", "", "99.2"]} +{"pcdb_id": 18067, "brand_name": "Ideal", "model_name": "LOGIC COMBI", "model_qualifier": "ESP1 30P", "winter_efficiency_pct": 90.1, "summer_efficiency_pct": 81.5, "comparative_hot_water_efficiency_pct": 57.3, "output_kw_max": 24.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018067", "000008", "0", "2018/Oct/15 12:00", "Ideal Boilers", "Ideal", "LOGIC COMBI", "ESP1 30P", "47-349-22", "2016", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "90.1", "81.5", "", "57.3", "", "2", "1", "", "104", "1", "2", "31", "5", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "", "", "", "", "92.0", "100.8", "", "", "", "", "99.2"]} +{"pcdb_id": 18068, "brand_name": "Ideal", "model_name": "LOGIC HEAT H24P", "model_qualifier": "", "winter_efficiency_pct": 90.1, "summer_efficiency_pct": 81.1, "comparative_hot_water_efficiency_pct": 59.2, "output_kw_max": 24.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018068", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "LOGIC HEAT H24P", "", "41-750-80", "2016", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "90.1", "81.1", "", "59.2", "", "2", "1", "", "102", "1", "2", "42", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "92.0", "100.8", "", "", "", "", "99.2"]} +{"pcdb_id": 18069, "brand_name": "Keston", "model_name": "KESTON COMBI C30P", "model_qualifier": "", "winter_efficiency_pct": 90.1, "summer_efficiency_pct": 81.5, "comparative_hot_water_efficiency_pct": 57.3, "output_kw_max": 24.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018069", "000022", "0", "2017/Jan/23 13:46", "Keston Boilers", "Keston", "KESTON COMBI C30P", "", "47-930-07", "2016", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "90.1", "81.5", "", "57.3", "", "2", "1", "", "104", "1", "2", "31", "5", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "", "", "", "", "92.0", "100.8", "", "", "", "", "99.2"]} +{"pcdb_id": 18070, "brand_name": "Keston", "model_name": "KESTON SYSTEM S30P", "model_qualifier": "", "winter_efficiency_pct": 89.8, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 59.1, "output_kw_max": 30.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018070", "000022", "0", "2017/May/15 15:31", "Keston Boilers", "Keston", "KESTON SYSTEM S30P", "", "41-930-45", "2016", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "30.3", "30.3", "", "", "89.8", "80.8", "", "59.1", "", "2", "1", "", "102", "1", "2", "48", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "", "", "", "", "91.6", "100.4", "", "", "", "", "98.7"]} +{"pcdb_id": 18071, "brand_name": "Navien", "model_name": "NCB-20LHWE", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 19.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018071", "000265", "0", "2020/Jun/02 09:22", "KD Navien", "Navien", "NCB-20LHWE", "", "41-709-01", "2014", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "19.5", "19.5", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "36", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "87.8", "97.8", "", "", "", "", "95.9"]} +{"pcdb_id": 18072, "brand_name": "Navien", "model_name": "NCB-23LHWE", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 23.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018072", "000265", "0", "2020/Jun/02 09:39", "KD Navien", "Navien", "NCB-23LHWE", "", "41-709-02", "2014", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "23.4", "23.4", "", "", "88.5", "79.5", "", "58.1", "", "2", "", "", "102", "1", "2", "45", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "87.9", "98.1", "", "", "", "", "96.2"]} +{"pcdb_id": 18073, "brand_name": "Navien", "model_name": "NCB-28LHWE", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 28.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018073", "000265", "0", "2020/Jun/02 09:46", "KD Navien", "Navien", "NCB-28LHWE", "", "41-709-03", "2014", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "28.3", "28.3", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "48", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "87.9", "97.8", "", "", "", "", "95.9"]} +{"pcdb_id": 18074, "brand_name": "Navien", "model_name": "NCB-33LHWE", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 33.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018074", "000265", "0", "2020/Jun/02 10:03", "KD Navien", "Navien", "NCB-33LHWE", "", "41-709-04", "2014", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "33.2", "33.2", "", "", "88.5", "79.5", "", "58.0", "", "2", "", "", "102", "1", "2", "45", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "87.8", "98.0", "", "", "", "", "96.1"]} +{"pcdb_id": 18089, "brand_name": "Ideal", "model_name": "VOGUE", "model_qualifier": "C26 GEN2", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 76.2, "output_kw_max": 26.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.001, "loss_factor_f1_kwh_per_day": 0.84569, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018089", "000008", "0", "2017/May/15 15:31", "Ideal Boilers", "Ideal", "VOGUE", "C26 GEN2", "47-349-38", "2017", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "26", "26", "", "", "88.6", "87.3", "", "76.2", "", "2", "", "", "104", "1", "2", "47", "3", "0", "", "", "", "0", "", "", "", "", "1", "6.915", "0.085", "0.001", "0.84569", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "", "", "", "", "89.7", "97.7", "", "", "", "", "96.2"]} +{"pcdb_id": 18090, "brand_name": "Ideal", "model_name": "VOGUE", "model_qualifier": "C32 GEN2", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 77.6, "output_kw_max": 32.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.001, "loss_factor_f1_kwh_per_day": 0.72908, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018090", "000008", "0", "2017/May/15 15:31", "Ideal Boilers", "Ideal", "VOGUE", "C32 GEN2", "47-349-39", "2017", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "32", "32", "", "", "88.7", "87.3", "", "77.6", "", "2", "", "", "104", "1", "2", "63", "3", "0", "", "", "", "0", "", "", "", "", "1", "6.79", "0.087", "0.001", "0.72908", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "", "", "", "", "89.9", "97.8", "", "", "", "", "96.3"]} +{"pcdb_id": 18091, "brand_name": "Ideal", "model_name": "VOGUE", "model_qualifier": "C40 GEN2", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 77.2, "output_kw_max": 40.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.001, "loss_factor_f1_kwh_per_day": 0.75466, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018091", "000008", "0", "2017/May/15 15:31", "Ideal Boilers", "Ideal", "VOGUE", "C40 GEN2", "47-349-40", "2017", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "40", "40", "", "", "88.6", "87.3", "", "77.2", "", "2", "", "", "104", "1", "2", "44", "3", "0", "", "", "", "0", "", "", "", "", "1", "6.821", "0.086", "0.001", "0.75466", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "", "", "", "", "89.7", "97.5", "", "", "", "", "96.0"]} +{"pcdb_id": 18092, "brand_name": "Ideal", "model_name": "VOGUE", "model_qualifier": "C26P GEN2", "winter_efficiency_pct": 89.6, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 57.0, "output_kw_max": 26.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018092", "000008", "0", "2017/May/15 15:31", "Ideal Boilers", "Ideal", "VOGUE", "C26P GEN2", "47-349-38", "2017", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "26", "26", "", "", "89.6", "81.0", "", "57.0", "", "2", "1", "", "104", "1", "2", "47", "3", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0015", "", "", "", "", "", "", "", "", "91.7", "99.8", "", "", "", "", "98.3"]} +{"pcdb_id": 18093, "brand_name": "Ideal", "model_name": "VOGUE", "model_qualifier": "C32P GEN2", "winter_efficiency_pct": 89.7, "summer_efficiency_pct": 81.1, "comparative_hot_water_efficiency_pct": 57.1, "output_kw_max": 32.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018093", "000008", "0", "2017/May/15 15:31", "Ideal Boilers", "Ideal", "VOGUE", "C32P GEN2", "47-349-39", "2017", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "32", "32", "", "", "89.7", "81.1", "", "57.1", "", "2", "1", "", "104", "1", "2", "63", "3", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0015", "", "", "", "", "", "", "", "", "91.9", "100.0", "", "", "", "", "98.5"]} +{"pcdb_id": 18094, "brand_name": "Ideal", "model_name": "VOGUE", "model_qualifier": "S15 GEN2", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 15.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018094", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "VOGUE", "S15 GEN2", "41-750-86", "2017", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "15", "15", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "25", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "89.6", "97.0", "", "", "", "", "95.6"]} +{"pcdb_id": 18095, "brand_name": "Ideal", "model_name": "VOGUE", "model_qualifier": "S18 GEN2", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 18.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018095", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "VOGUE", "S18 GEN2", "41-750-89", "2017", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18", "18", "", "", "88.7", "79.7", "", "58.2", "", "2", "", "", "102", "1", "2", "40", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "89.8", "97.8", "", "", "", "", "96.3"]} +{"pcdb_id": 18096, "brand_name": "Ideal", "model_name": "VOGUE", "model_qualifier": "S26 GEN2", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 26.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018096", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "VOGUE", "S26 GEN2", "41-750-90", "2017", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "26", "26", "", "", "88.7", "79.7", "", "58.2", "", "2", "", "", "102", "1", "2", "45", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "89.7", "97.8", "", "", "", "", "96.2"]} +{"pcdb_id": 18097, "brand_name": "Ideal", "model_name": "VOGUE", "model_qualifier": "S32 GEN2", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 32.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018097", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "VOGUE", "S32 GEN2", "41-750-91", "2017", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "32", "32", "", "", "88.7", "79.7", "", "58.2", "", "2", "", "", "102", "1", "2", "49", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "89.8", "97.8", "", "", "", "", "96.3"]} +{"pcdb_id": 18098, "brand_name": "Ideal", "model_name": "VOGUE", "model_qualifier": "S15P GEN2", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 80.4, "comparative_hot_water_efficiency_pct": 58.7, "output_kw_max": 15.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018098", "000008", "0", "2017/May/15 15:31", "Ideal Boilers", "Ideal", "VOGUE", "S15P GEN2", "41-750-88", "2017", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "15", "15", "", "", "89.4", "80.4", "", "58.7", "", "2", "1", "", "102", "1", "2", "25", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0015", "", "", "", "", "", "", "", "", "91.5", "99.2", "", "", "", "", "97.7"]} +{"pcdb_id": 18099, "brand_name": "Ideal", "model_name": "VOGUE", "model_qualifier": "S18P GEN2", "winter_efficiency_pct": 89.7, "summer_efficiency_pct": 80.7, "comparative_hot_water_efficiency_pct": 59.0, "output_kw_max": 18.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018099", "000008", "0", "2017/May/15 15:31", "Ideal Boilers", "Ideal", "VOGUE", "S18P GEN2", "41-750-89", "2017", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "18", "18", "", "", "89.7", "80.7", "", "59.0", "", "2", "1", "", "102", "1", "2", "40", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0015", "", "", "", "", "", "", "", "", "91.8", "100.0", "", "", "", "", "98.5"]} +{"pcdb_id": 18100, "brand_name": "Ideal", "model_name": "VOGUE", "model_qualifier": "S26P GEN2", "winter_efficiency_pct": 89.7, "summer_efficiency_pct": 80.7, "comparative_hot_water_efficiency_pct": 58.9, "output_kw_max": 26.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018100", "000008", "0", "2017/May/15 15:31", "Ideal Boilers", "Ideal", "VOGUE", "S26P GEN2", "41-750-90", "2017", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "26", "26", "", "", "89.7", "80.7", "", "58.9", "", "2", "1", "", "102", "1", "2", "45", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0015", "", "", "", "", "", "", "", "", "91.7", "99.9", "", "", "", "", "98.4"]} +{"pcdb_id": 18101, "brand_name": "Ideal", "model_name": "VOGUE", "model_qualifier": "S32P GEN2", "winter_efficiency_pct": 89.7, "summer_efficiency_pct": 80.7, "comparative_hot_water_efficiency_pct": 59.0, "output_kw_max": 32.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018101", "000008", "0", "2017/May/15 15:31", "Ideal Boilers", "Ideal", "VOGUE", "S32P GEN2", "41-750-91", "2017", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "32", "32", "", "", "89.7", "80.7", "", "59.0", "", "2", "1", "", "102", "1", "2", "49", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0015", "", "", "", "", "", "", "", "", "91.8", "100.0", "", "", "", "", "98.5"]} +{"pcdb_id": 18102, "brand_name": "Ideal", "model_name": "VOGUE", "model_qualifier": "C40P GEN2", "winter_efficiency_pct": 89.6, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 56.9, "output_kw_max": 40.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018102", "000008", "0", "2017/May/15 15:31", "Ideal Boilers", "Ideal", "VOGUE", "C40P GEN2", "47-349-40", "2017", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "40", "40", "", "", "89.6", "81.0", "", "56.9", "", "2", "1", "", "104", "1", "2", "44", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0015", "", "", "", "", "", "", "", "", "91.7", "99.7", "", "", "", "", "98.1"]} +{"pcdb_id": 18103, "brand_name": "Sime", "model_name": "MURELLE ONE HE 25", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 87.0, "comparative_hot_water_efficiency_pct": 67.1, "output_kw_max": 20.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.005, "loss_factor_f1_kwh_per_day": 1.70563, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018103", "000213", "0", "2017/Mar/10 11:26", "Fonderie Sime S.p.A.", "Sime", "MURELLE ONE HE 25", "", "8115010", "2017", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "20", "20", "", "", "88.5", "87.0", "", "67.1", "", "2", "", "", "104", "1", "2", "26", "4", "0", "", "", "", "0", "", "", "", "", "1", "7.851", "0.031", "0.005", "1.70563", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.9", "97.6", "", "", "", "", "95.9"]} +{"pcdb_id": 18104, "brand_name": "Baxi", "model_name": "HEAT", "model_qualifier": "212", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 13.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018104", "000005", "0", "2018/Jun/18 14:27", "Baxi Heating", "Baxi", "HEAT", "212", "41-470-45", "2017", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "13.0", "13.0", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "17", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.3", "98.0", "", "", "", "", "96.0"]} +{"pcdb_id": 18105, "brand_name": "Baxi", "model_name": "HEAT", "model_qualifier": "215", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 16.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018105", "000005", "0", "2018/Jun/18 14:27", "Baxi Heating", "Baxi", "HEAT", "215", "41-470-46", "2017", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "16.0", "16.0", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "20", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.3", "98.0", "", "", "", "", "96.0"]} +{"pcdb_id": 18106, "brand_name": "Baxi", "model_name": "HEAT", "model_qualifier": "218", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 19.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018106", "000005", "0", "2018/Jun/18 14:28", "Baxi Heating", "Baxi", "HEAT", "218", "41-470-47", "2017", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "19.0", "19.0", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "23", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.3", "98.0", "", "", "", "", "96.0"]} +{"pcdb_id": 18107, "brand_name": "Baxi", "model_name": "HEAT", "model_qualifier": "224", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 25.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018107", "000005", "0", "2018/Jun/18 14:28", "Baxi Heating", "Baxi", "HEAT", "224", "41-470-48", "2017", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "25.0", "25.0", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "33", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.3", "98.0", "", "", "", "", "96.0"]} +{"pcdb_id": 18108, "brand_name": "Baxi", "model_name": "HEAT", "model_qualifier": "230", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 30.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018108", "000005", "0", "2018/Jun/18 14:29", "Baxi Heating", "Baxi", "HEAT", "230", "41-470-49", "2017", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "30.0", "30.0", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "44", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.3", "98.0", "", "", "", "", "96.0"]} +{"pcdb_id": 18109, "brand_name": "Baxi", "model_name": "HEAT", "model_qualifier": "412", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 13.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018109", "000005", "0", "2018/Jun/18 14:30", "Baxi Heating", "Baxi", "HEAT", "412", "41-470-50", "2017", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "13.0", "13.0", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "17", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.3", "98.0", "", "", "", "", "96.0"]} +{"pcdb_id": 18110, "brand_name": "Baxi", "model_name": "HEAT", "model_qualifier": "415", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 16.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018110", "000005", "0", "2018/Jun/18 14:30", "Baxi Heating", "Baxi", "HEAT", "415", "41-470-51", "2017", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "16.0", "16.0", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "20", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.3", "98.0", "", "", "", "", "96.0"]} +{"pcdb_id": 18111, "brand_name": "Baxi", "model_name": "HEAT", "model_qualifier": "418", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 19.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018111", "000005", "0", "2018/Jun/18 14:31", "Baxi Heating", "Baxi", "HEAT", "418", "41-470-52", "2017", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "19.0", "19.0", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "23", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.3", "98.0", "", "", "", "", "96.0"]} +{"pcdb_id": 18112, "brand_name": "Baxi", "model_name": "HEAT", "model_qualifier": "424", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 25.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018112", "000005", "0", "2018/Jun/18 14:31", "Baxi Heating", "Baxi", "HEAT", "424", "41-470-53", "2017", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "25.0", "25.0", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "33", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.3", "98.0", "", "", "", "", "96.0"]} +{"pcdb_id": 18113, "brand_name": "Baxi", "model_name": "HEAT", "model_qualifier": "430", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 30.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018113", "000005", "0", "2018/Jun/18 14:31", "Baxi Heating", "Baxi", "HEAT", "430", "41-470-54", "2017", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "30.0", "30.0", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "44", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.3", "98.0", "", "", "", "", "96.0"]} +{"pcdb_id": 18115, "brand_name": "icon Heating", "model_name": "Base Cube", "model_qualifier": "24/35 UK", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 55.8, "output_kw_max": 24.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018115", "000304", "0", "2017/Jun/19 09:16", "Icon Heating Solutions", "icon Heating", "Base Cube", "24/35 UK", "03-00259", "2011", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.0", "24.0", "", "", "87.9", "79.3", "", "55.8", "", "2", "", "", "104", "1", "2", "30", "4", "0", "", "", "0.02", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "86.6", "97.1", "", "", "", "", "95.1"]} +{"pcdb_id": 18116, "brand_name": "icon Heating", "model_name": "Base Cube", "model_qualifier": "30/35 UK", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 86.2, "comparative_hot_water_efficiency_pct": 82.0, "output_kw_max": 30.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0009, "loss_factor_f1_kwh_per_day": 0.29516, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018116", "000304", "0", "2017/Oct/18 12:51", "Icon Heating Solutions", "icon Heating", "Base Cube", "30/35 UK", "03-00261", "2011", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "30.0", "30.0", "", "", "88.1", "86.2", "", "82.0", "", "2", "", "", "104", "1", "2", "30", "4", "0", "", "", "0.02", "0", "", "", "", "", "1", "6.424", "0.109", "0.0009", "0.29516", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "86.5", "97.6", "", "", "", "", "95.5"]} +{"pcdb_id": 18117, "brand_name": "icon Heating", "model_name": "Base Cube", "model_qualifier": "Duo 24/35 UK", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 86.2, "comparative_hot_water_efficiency_pct": 82.0, "output_kw_max": 24.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0009, "loss_factor_f1_kwh_per_day": 0.29726, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018117", "000304", "0", "2017/Oct/18 12:50", "Icon Heating Solutions", "icon Heating", "Base Cube", "Duo 24/35 UK", "03-00262", "2011", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.0", "24.0", "", "", "87.9", "86.2", "", "82.0", "", "2", "", "", "104", "1", "2", "30", "4", "0", "", "", "0.02", "0", "", "", "", "", "1", "6.424", "0.109", "0.0009", "0.29726", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "86.6", "97.1", "", "", "", "", "95.1"]} +{"pcdb_id": 18118, "brand_name": "Vaillant", "model_name": "ecoTEC sustain 24", "model_qualifier": "VUW 246/7-2 (H-GB)", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 75.7, "comparative_hot_water_efficiency_pct": 76.3, "output_kw_max": 18.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.015, "loss_factor_f1_kwh_per_day": 0.73143, "loss_factor_f2_kwh_per_day": 0.0, "rejected_factor_f3_per_litre": 0.00014, "raw": ["018118", "000031", "0", "2020/Nov/17 08:51", "Vaillant", "Vaillant", "ecoTEC sustain 24", "VUW 246/7-2 (H-GB)", "47-044-79", "2017", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "18.5", "18.5", "", "", "88.6", "75.7", "", "76.3", "", "2", "", "", "104", "1", "2", "19", "2", "0", "", "", "", "0", "", "", "", "", "2", "6.9", "0.0826", "0.015", "0.73143", "13.729", "0.115", "0.0015", "0.0", "0.00014", "", "", "", "0045", "", "", "", "", "", "", "", "", "89.0", "97.9", "", "", "", "", "96.2"]} +{"pcdb_id": 18119, "brand_name": "Vaillant", "model_name": "ecoTEC sustain 28", "model_qualifier": "VUW 286/7-2 (H-GB)", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 87.0, "comparative_hot_water_efficiency_pct": 78.8, "output_kw_max": 18.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0101, "loss_factor_f1_kwh_per_day": 0.55445, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018119", "000031", "0", "2020/Nov/17 08:57", "Vaillant", "Vaillant", "ecoTEC sustain 28", "VUW 286/7-2 (H-GB)", "47-044-80", "2017", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "18.5", "18.5", "", "", "88.5", "87.0", "", "78.8", "", "2", "", "", "104", "1", "2", "23", "2", "0", "", "", "", "0", "", "", "", "", "1", "6.6848", "0.0935", "0.0101", "0.55445", "13.492", "0.111", "", "", "", "", "", "", "0045", "", "", "", "", "", "", "", "", "89.1", "97.6", "", "", "", "", "96.0"]} +{"pcdb_id": 18120, "brand_name": "Vaillant", "model_name": "ecoTEC sustain 34", "model_qualifier": "VUW 346/7-2 (H-GB)", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 76.9, "output_kw_max": 18.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.0196, "loss_factor_f1_kwh_per_day": 0.65323, "loss_factor_f2_kwh_per_day": 0.0, "rejected_factor_f3_per_litre": 0.00019, "raw": ["018120", "000031", "0", "2021/Feb/15 12:44", "Vaillant", "Vaillant", "ecoTEC sustain 34", "VUW 346/7-2 (H-GB)", "47-044-81", "2017", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "18.5", "18.5", "", "", "88.6", "79.6", "", "76.9", "", "2", "", "", "104", "1", "2", "13", "3", "0", "", "", "", "0", "", "", "", "", "2", "6.8447", "0.1233", "0.0196", "0.65323", "13.3017", "0.1249", "0.0007", "0.0", "0.00019", "", "", "", "0045", "", "", "", "", "", "", "", "", "89.1", "97.8", "", "", "", "", "96.1"]} +{"pcdb_id": 18121, "brand_name": "Ideal", "model_name": "LOGIC CODE COMBI ESP1", "model_qualifier": "26", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 85.7, "output_kw_max": 24.3, "final_year_of_manufacture": null, "subsidiary_type": 1, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.002, "loss_factor_f1_kwh_per_day": 0.09826, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018121", "000008", "0", "2018/Apr/03 13:51", "Ideal Boilers", "Ideal", "LOGIC CODE COMBI ESP1", "26", "47-349-35", "2016", "current", "1", "2", "1", "2", "1", "", "", "2", "2", "2", "24.3", "24.3", "", "", "89.0", "87.3", "", "85.7", "", "2", "", "", "104", "1", "2", "34", "3", "0", "", "", "", "0", "", "", "", "", "1", "6.143", "0.074", "0.002", "0.09826", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "", "", "", "", "90.0", "98.6", "", "", "", "", "96.9"]} +{"pcdb_id": 18122, "brand_name": "Ideal", "model_name": "LOGIC CODE COMBI ESP1", "model_qualifier": "33", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 85.9, "output_kw_max": 24.3, "final_year_of_manufacture": null, "subsidiary_type": 1, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0015, "loss_factor_f1_kwh_per_day": 0.08761, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018122", "000008", "0", "2017/May/25 12:26", "Ideal Boilers", "Ideal", "LOGIC CODE COMBI ESP1", "33", "47-349-36", "2016", "current", "1", "2", "1", "2", "1", "", "", "2", "2", "2", "24.3", "24.3", "", "", "89.0", "87.3", "", "85.9", "", "2", "", "", "104", "1", "2", "41", "3", "0", "", "", "", "0", "", "", "", "", "1", "6.129", "0.073", "0.0015", "0.08761", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "", "", "", "", "90.0", "98.6", "", "", "", "", "96.9"]} +{"pcdb_id": 18123, "brand_name": "Ideal", "model_name": "LOGIC CODE COMBI ESP1", "model_qualifier": "38", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 84.8, "output_kw_max": 24.3, "final_year_of_manufacture": null, "subsidiary_type": 1, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.002, "loss_factor_f1_kwh_per_day": 0.16321, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018123", "000008", "0", "2017/May/25 12:19", "Ideal Boilers", "Ideal", "LOGIC CODE COMBI ESP1", "38", "47-349-37", "2016", "current", "1", "2", "1", "2", "1", "", "", "2", "2", "2", "24.3", "24.3", "", "", "89.0", "87.3", "", "84.8", "", "2", "", "", "104", "1", "2", "41", "3", "0", "", "", "", "0", "", "", "", "", "1", "6.21", "0.074", "0.002", "0.16321", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "", "", "", "", "90.0", "98.6", "", "", "", "", "96.9"]} +{"pcdb_id": 18124, "brand_name": "Ideal", "model_name": "LOGIC CODE COMBI ESP1", "model_qualifier": "33P", "winter_efficiency_pct": 90.1, "summer_efficiency_pct": 81.5, "comparative_hot_water_efficiency_pct": 57.3, "output_kw_max": 24.3, "final_year_of_manufacture": null, "subsidiary_type": 1, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018124", "000008", "0", "2017/May/25 12:32", "Ideal Boilers", "Ideal", "LOGIC CODE COMBI ESP1", "33P", "47-349-36", "2016", "current", "2", "2", "1", "2", "1", "", "", "2", "2", "2", "24.3", "24.3", "", "", "90.1", "81.5", "", "57.3", "", "2", "1", "", "104", "1", "2", "41", "3", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "", "", "", "", "92.0", "100.8", "", "", "", "", "99.1"]} +{"pcdb_id": 18125, "brand_name": "Ideal", "model_name": "LOGIC CODE COMBI ESP1", "model_qualifier": "38P", "winter_efficiency_pct": 90.1, "summer_efficiency_pct": 81.5, "comparative_hot_water_efficiency_pct": 57.3, "output_kw_max": 24.3, "final_year_of_manufacture": null, "subsidiary_type": 1, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018125", "000008", "0", "2017/May/25 12:31", "Ideal Boilers", "Ideal", "LOGIC CODE COMBI ESP1", "38P", "47-349-37", "2016", "current", "2", "2", "1", "2", "1", "", "", "2", "2", "2", "24.3", "24.3", "", "", "90.1", "81.5", "", "57.3", "", "2", "1", "", "104", "1", "2", "41", "3", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "", "", "", "", "92.0", "100.8", "", "", "", "", "99.1"]} +{"pcdb_id": 18127, "brand_name": "Viessmann", "model_name": "Vitodens 100-W", "model_qualifier": "B1HC-19", "winter_efficiency_pct": 89.6, "summer_efficiency_pct": 80.6, "comparative_hot_water_efficiency_pct": 58.8, "output_kw_max": 17.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018127", "000033", "0", "2017/Apr/12 16:53", "Viessmann", "Viessmann", "Vitodens 100-W", "B1HC-19", "41-819-40", "2016", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "17.4", "17.4", "", "", "89.6", "80.6", "", "58.8", "", "2", "0", "", "102", "1", "2", "19", "60", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.8", "97.4", "", "", "", "", "96.2"]} +{"pcdb_id": 18128, "brand_name": "Viessmann", "model_name": "Vitodens 100-W", "model_qualifier": "B1HC-26", "winter_efficiency_pct": 89.8, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 59.0, "output_kw_max": 23.8, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018128", "000033", "0", "2017/Apr/12 16:53", "Viessmann", "Viessmann", "Vitodens 100-W", "B1HC-26", "41-819-41", "2016", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "23.8", "23.8", "", "", "89.8", "80.8", "", "59.0", "", "2", "0", "", "102", "1", "2", "19", "60", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.8", "98.0", "", "", "", "", "96.6"]} +{"pcdb_id": 18129, "brand_name": "Viessmann", "model_name": "Vitodens 100-W", "model_qualifier": "B1HC-30", "winter_efficiency_pct": 90.0, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 59.1, "output_kw_max": 27.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018129", "000033", "0", "2017/Apr/12 16:53", "Viessmann", "Viessmann", "Vitodens 100-W", "B1HC-30", "41-819-412", "2016", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "27.5", "27.5", "", "", "90.0", "81.0", "", "59.1", "", "2", "0", "", "102", "1", "2", "24", "58", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "91.0", "98.4", "", "", "", "", "97.0"]} +{"pcdb_id": 18130, "brand_name": "Viessmann", "model_name": "Vitodens 100-W", "model_qualifier": "B1HC-35", "winter_efficiency_pct": 90.1, "summer_efficiency_pct": 81.1, "comparative_hot_water_efficiency_pct": 59.3, "output_kw_max": 32.1, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018130", "000033", "0", "2017/Apr/12 16:53", "Viessmann", "Viessmann", "Vitodens 100-W", "B1HC-35", "41-819-43", "2016", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "32.1", "32.1", "", "", "90.1", "81.1", "", "59.3", "", "2", "0", "", "102", "1", "2", "25", "58", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "91.4", "98.6", "", "", "", "", "97.3"]} +{"pcdb_id": 18131, "brand_name": "Viessmann", "model_name": "Vitodens 100-W", "model_qualifier": "B1KC-26", "winter_efficiency_pct": 89.8, "summer_efficiency_pct": 81.2, "comparative_hot_water_efficiency_pct": 57.1, "output_kw_max": 23.8, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018131", "000033", "0", "2017/Apr/12 16:53", "Viessmann", "Viessmann", "Vitodens 100-W", "B1KC-26", "47-819-40", "2016", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "23.8", "23.8", "", "", "89.8", "81.2", "", "57.1", "", "2", "0", "", "104", "1", "2", "22", "59", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.8", "98.0", "", "", "", "", "96.6"]} +{"pcdb_id": 18132, "brand_name": "Viessmann", "model_name": "Vitodens 100-W", "model_qualifier": "B1KC-30", "winter_efficiency_pct": 90.0, "summer_efficiency_pct": 81.4, "comparative_hot_water_efficiency_pct": 57.2, "output_kw_max": 27.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018132", "000033", "0", "2017/Apr/12 16:53", "Viessmann", "Viessmann", "Vitodens 100-W", "B1KC-30", "47-819-41", "2016", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "27.5", "27.5", "", "", "90.0", "81.4", "", "57.2", "", "2", "0", "", "104", "1", "2", "24", "58", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "91.0", "98.4", "", "", "", "", "97.0"]} +{"pcdb_id": 18133, "brand_name": "Viessmann", "model_name": "Vitodens 100-W", "model_qualifier": "B1KC-35", "winter_efficiency_pct": 90.1, "summer_efficiency_pct": 81.5, "comparative_hot_water_efficiency_pct": 57.3, "output_kw_max": 32.1, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018133", "000033", "0", "2017/Apr/12 16:54", "Viessmann", "Viessmann", "Vitodens 100-W", "B1KC-35", "47-819-42", "2016", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "32.1", "32.1", "", "", "90.1", "81.5", "", "57.3", "", "2", "0", "", "104", "1", "2", "25", "58", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "91.4", "98.6", "", "", "", "", "97.3"]} +{"pcdb_id": 18134, "brand_name": "Viessmann", "model_name": "Vitodens 050-W BPJD", "model_qualifier": "29kW", "winter_efficiency_pct": 89.3, "summer_efficiency_pct": 90.3, "comparative_hot_water_efficiency_pct": 72.5, "output_kw_max": 21.9, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.002, "loss_factor_f1_kwh_per_day": 1.30217, "loss_factor_f2_kwh_per_day": 1.2776, "rejected_factor_f3_per_litre": 1e-05, "raw": ["018134", "000033", "0", "2020/Apr/09 16:01", "Viessmann", "Viessmann", "Vitodens 050-W BPJD", "29kW", "47-819-38", "2016", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "21.9", "21.9", "", "", "89.3", "90.3", "", "72.5", "", "2", "0", "", "104", "1", "2", "17", " 3", "0", "", "", "", "0", "", "", "", "", "2", "7.425", "0.106", "0.002", "1.30217", "13.336", "0.12", "0.001", "1.2776", "0.00001", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.5", "97.0", "", "", "", "", "95.8"]} +{"pcdb_id": 18136, "brand_name": "Sime", "model_name": "MURELLE HE 70 R ErP", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 63.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018136", "000213", "0", "2017/May/10 17:02", "Fonderie Sime S.p.A.", "Sime", "MURELLE HE 70 R ErP", "", "8104981", "2017", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "63.4", "63.4", "", "", "88.3", "79.3", "", "57.9", "", "2", "", "", "102", "1", "2", "18", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "97.6", "", "", "", "", "95.7"]} +{"pcdb_id": 18137, "brand_name": "Trianco", "model_name": "Slimline Combi", "model_qualifier": "26", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 82.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 26.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018137", "000047", "0", "2017/May/17 11:52", "Firebird Heating Solutions Ltd", "Trianco", "Slimline Combi", "26", "", "2009", "current", "4", "1", "1", "2", "0", "", "", "2", "2", "1", "26", "26", "", "", "89.4", "82.0", "", "57.7", "", "2", "", "", "202", "1", "1", "148", "3", "0", "", "", "11.01", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "93.0", "97.5", "", "", "", "", "96.7"]} +{"pcdb_id": 18138, "brand_name": "Trianco", "model_name": "Heatpac Condensing Boiler", "model_qualifier": "12-20kW", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 81.6, "comparative_hot_water_efficiency_pct": 59.6, "output_kw_max": 20.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018138", "000047", "0", "2017/May/04 16:34", "Firebird Heating Solutions Ltd", "Trianco", "Heatpac Condensing Boiler", "12-20kW", "", "2009", "current", "4", "1", "2", "1", "0", "", "", "2", "1", "1", "12.0", "20.0", "", "", "89.4", "81.6", "", "59.6", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "93.1", "97.4", "", "", "", "", "96.6"]} +{"pcdb_id": 18139, "brand_name": "Trianco", "model_name": "Heatpac Condensing Boiler", "model_qualifier": "20/26kW", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 81.6, "comparative_hot_water_efficiency_pct": 59.6, "output_kw_max": 26.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018139", "000047", "0", "2017/May/17 11:51", "Firebird Heating Solutions Ltd", "Trianco", "Heatpac Condensing Boiler", "20/26kW", "", "2009", "current", "4", "1", "2", "1", "0", "", "", "2", "1", "1", "20", "26", "", "", "89.4", "81.6", "", "59.6", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "93.0", "97.5", "", "", "", "", "96.7"]} +{"pcdb_id": 18140, "brand_name": "Trianco", "model_name": "Slimline Combi", "model_qualifier": "20", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 82.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 20.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018140", "000047", "0", "2017/May/17 11:51", "Firebird Heating Solutions Ltd", "Trianco", "Slimline Combi", "20", "", "2009", "current", "4", "1", "1", "2", "0", "", "", "2", "2", "1", "20", "20", "", "", "89.4", "82.0", "", "57.7", "", "2", "", "", "202", "1", "1", "", "", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "93.1", "97.4", "", "", "", "", "96.6"]} +{"pcdb_id": 18141, "brand_name": "Saturn", "model_name": "NHC 25H", "model_qualifier": "", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 81.1, "comparative_hot_water_efficiency_pct": 59.2, "output_kw_max": 24.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018141", "000268", "0", "2017/Jun/13 10:28", "KD Navien", "Saturn", "NHC 25H", "", "", "2006", "current", "4", "1", "1", "1", "0", "", "", "2", "1", "2", "24.0", "24.0", "", "", "88.9", "81.1", "", "59.2", "", "2", "", "", "201", "1", "1", "136", "13", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.5", "96.7", "", "", "", "", "95.7"]} +{"pcdb_id": 18142, "brand_name": "Saturn", "model_name": "NHC 25EH", "model_qualifier": "", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 81.1, "comparative_hot_water_efficiency_pct": 59.2, "output_kw_max": 24.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018142", "000268", "0", "2017/Jun/13 10:27", "KD Navien", "Saturn", "NHC 25EH", "", "", "2006", "current", "4", "1", "2", "1", "0", "", "", "2", "1", "2", "24.0", "24.0", "", "", "88.9", "81.1", "", "59.2", "", "2", "", "", "201", "1", "1", "136", "13", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.5", "96.7", "", "", "", "", "95.7"]} +{"pcdb_id": 18143, "brand_name": "Saturn", "model_name": "NCH 30H", "model_qualifier": "", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 80.4, "comparative_hot_water_efficiency_pct": 58.7, "output_kw_max": 27.9, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018143", "000268", "0", "2017/Jun/13 10:27", "KD Navien", "Saturn", "NCH 30H", "", "", "2006", "current", "4", "1", "1", "1", "0", "", "", "2", "1", "2", "27.9", "27.9", "", "", "88.2", "80.4", "", "58.7", "", "2", "", "", "201", "1", "1", "145", "14", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.7", "95.4", "", "", "", "", "94.5"]} +{"pcdb_id": 18144, "brand_name": "Saturn", "model_name": "NHC 30EH", "model_qualifier": "", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 80.4, "comparative_hot_water_efficiency_pct": 58.7, "output_kw_max": 27.9, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018144", "000268", "0", "2017/Jun/13 10:26", "KD Navien", "Saturn", "NHC 30EH", "", "", "2006", "current", "4", "1", "2", "1", "0", "", "", "2", "1", "2", "27.9", "27.9", "", "", "88.2", "80.4", "", "58.7", "", "2", "", "", "201", "1", "1", "145", "14", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.7", "95.4", "", "", "", "", "94.5"]} +{"pcdb_id": 18145, "brand_name": "Saturn", "model_name": "NHC 41H", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 80.7, "comparative_hot_water_efficiency_pct": 58.9, "output_kw_max": 36.8, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018145", "000268", "0", "2017/Jun/13 10:25", "KD Navien", "Saturn", "NHC 41H", "", "", "2006", "current", "4", "1", "1", "1", "0", "", "", "2", "1", "2", "36.8", "36.8", "", "", "88.5", "80.7", "", "58.9", "", "2", "", "", "201", "1", "1", "163", "12", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.1", "95.9", "", "", "", "", "95.0"]} +{"pcdb_id": 18146, "brand_name": "Saturn", "model_name": "NHC 41EH", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 80.7, "comparative_hot_water_efficiency_pct": 58.9, "output_kw_max": 36.8, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018146", "000268", "0", "2017/Jun/14 09:43", "KD Navien", "Saturn", "NHC 41EH", "", "", "2006", "current", "4", "1", "2", "1", "0", "", "", "2", "1", "2", "36.8", "36.8", "", "", "88.5", "80.7", "", "58.9", "", "2", "", "", "201", "1", "1", "163", "12", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.1", "95.9", "", "", "", "", "95.0"]} +{"pcdb_id": 18147, "brand_name": "Trianco", "model_name": "Kitchen Condensing Boiler", "model_qualifier": "12-18kW", "winter_efficiency_pct": 89.3, "summer_efficiency_pct": 81.5, "comparative_hot_water_efficiency_pct": 59.5, "output_kw_max": 18.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018147", "000047", "0", "2017/May/17 11:53", "Firebird Heating Solutions Ltd", "Trianco", "Kitchen Condensing Boiler", "12-18kW", "", "2015", "current", "4", "1", "1", "1", "0", "", "", "2", "2", "1", "12", "18", "", "", "89.3", "81.5", "", "59.5", "", "2", "", "", "201", "1", "1", "163", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "92.8", "97.3", "", "", "", "", "96.4"]} +{"pcdb_id": 18148, "brand_name": "Trianco", "model_name": "Kitchen Condensing Boiler", "model_qualifier": "12-20kW", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 81.6, "comparative_hot_water_efficiency_pct": 59.6, "output_kw_max": 20.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018148", "000047", "0", "2017/May/17 11:53", "Firebird Heating Solutions Ltd", "Trianco", "Kitchen Condensing Boiler", "12-20kW", "", "2009", "current", "4", "1", "1", "1", "0", "", "", "2", "2", "1", "12", "20", "", "", "89.4", "81.6", "", "59.6", "", "2", "", "", "201", "1", "1", "158", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "93.1", "97.4", "", "", "", "", "96.6"]} +{"pcdb_id": 18149, "brand_name": "Trianco", "model_name": "Kitchen Condensing Boiler", "model_qualifier": "20-26kW", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 81.6, "comparative_hot_water_efficiency_pct": 59.6, "output_kw_max": 26.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018149", "000047", "0", "2017/May/17 11:53", "Firebird Heating Solutions Ltd", "Trianco", "Kitchen Condensing Boiler", "20-26kW", "", "2009", "current", "4", "1", "1", "1", "0", "", "", "2", "2", "1", "20", "26", "", "", "89.4", "81.6", "", "59.6", "", "2", "", "", "201", "1", "1", "14.8", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "93.0", "97.5", "", "", "", "", "96.7"]} +{"pcdb_id": 18150, "brand_name": "Alpha", "model_name": "Evoke", "model_qualifier": "33 LPG", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 90.3, "comparative_hot_water_efficiency_pct": 77.1, "output_kw_max": 28.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.0045, "loss_factor_f1_kwh_per_day": 0.84841, "loss_factor_f2_kwh_per_day": 0.83445, "rejected_factor_f3_per_litre": 1e-05, "raw": ["018150", "000001", "0", "2020/Apr/09 15:58", "Alpha Therm", "Alpha", "Evoke", "33 LPG", "3.027377GPL", "2017", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "28", "28", "", "", "89.4", "90.3", "", "77.1", "", "2", "1", "", "104", "1", "2", "12", "2", "0", "", "", "", "0", "", "", "", "", "2", "6.979", "0.096", "0.0045", "0.84841", "12.541", "0.117", "0.004", "0.83445", "0.00001", "", "", "", "1005", "", "", "", "", "", "", "", "", "90.2", "99.8", "", "", "", "", "98.0"]} +{"pcdb_id": 18151, "brand_name": "Alpha", "model_name": "Evoke", "model_qualifier": "28 LPG", "winter_efficiency_pct": 89.3, "summer_efficiency_pct": 88.9, "comparative_hot_water_efficiency_pct": 77.5, "output_kw_max": 24.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.009, "loss_factor_f1_kwh_per_day": 0.7871, "loss_factor_f2_kwh_per_day": 0.67526, "rejected_factor_f3_per_litre": 5e-05, "raw": ["018151", "000001", "0", "2020/Apr/09 15:57", "Alpha Therm", "Alpha", "Evoke", "28 LPG", "3.027376GPL", "2017", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "89.3", "88.9", "", "77.5", "", "2", "1", "", "104", "1", "2", "10", "2", "0", "", "", "", "0", "", "", "", "", "2", "6.945", "0.08", "0.009", "0.7871", "12.961", "0.11", "0.0045", "0.67526", "0.00005", "", "", "", "1005", "", "", "", "", "", "", "", "", "90.1", "99.7", "", "", "", "", "97.9"]} +{"pcdb_id": 18152, "brand_name": "Alpha", "model_name": "E-Tec", "model_qualifier": "33 LPG", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 90.3, "comparative_hot_water_efficiency_pct": 77.1, "output_kw_max": 28.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.0045, "loss_factor_f1_kwh_per_day": 0.84841, "loss_factor_f2_kwh_per_day": 0.83445, "rejected_factor_f3_per_litre": 1e-05, "raw": ["018152", "000001", "0", "2020/Apr/09 15:55", "Alpha Therm", "Alpha", "E-Tec", "33 LPG", "3.027375GPL", "2017", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "28", "28", "", "", "89.4", "90.3", "", "77.1", "", "2", "1", "", "104", "1", "2", "12", "2", "0", "", "", "", "0", "", "", "", "", "2", "6.979", "0.096", "0.0045", "0.84841", "12.541", "0.117", "0.004", "0.83445", "0.00001", "", "", "", "1005", "", "", "", "", "", "", "", "", "90.2", "99.8", "", "", "", "", "98.0"]} +{"pcdb_id": 18153, "brand_name": "Alpha", "model_name": "E-Tec", "model_qualifier": "28 LPG", "winter_efficiency_pct": 89.3, "summer_efficiency_pct": 90.3, "comparative_hot_water_efficiency_pct": 77.5, "output_kw_max": 24.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.009, "loss_factor_f1_kwh_per_day": 0.7871, "loss_factor_f2_kwh_per_day": 0.77548, "rejected_factor_f3_per_litre": 5e-05, "raw": ["018153", "000001", "0", "2020/Apr/09 15:54", "Alpha Therm", "Alpha", "E-Tec", "28 LPG", "3.027374GPL", "2017", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "89.3", "90.3", "", "77.5", "", "2", "1", "", "104", "1", "2", "10", "2", "0", "", "", "", "0", "", "", "", "", "2", "6.945", "0.119", "0.009", "0.7871", "12.691", "0.11", "0.0045", "0.77548", "0.00005", "", "", "", "1005", "", "", "", "", "", "", "", "", "90.1", "99.7", "", "", "", "", "97.9"]} +{"pcdb_id": 18154, "brand_name": "Alpha", "model_name": "E-Tec", "model_qualifier": "33", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 88.2, "comparative_hot_water_efficiency_pct": 74.7, "output_kw_max": 28.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.0085, "loss_factor_f1_kwh_per_day": 0.89436, "loss_factor_f2_kwh_per_day": 0.86958, "rejected_factor_f3_per_litre": 5e-05, "raw": ["018154", "000001", "0", "2020/Apr/09 15:52", "Alpha Therm", "Alpha", "E-Tec", "33", "3.027375", "2017", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28", "28", "", "", "88.4", "88.2", "", "74.7", "", "2", "", "", "104", "1", "2", "12", "2", "0", "", "", "", "0", "", "", "", "", "2", "7.051", "0.095", "0.0085", "0.89436", "12.849", "0.125", "0.004", "0.86958", "0.00005", "", "", "", "1005", "", "", "", "", "", "", "", "", "88.2", "97.7", "", "", "", "", "95.9"]} +{"pcdb_id": 18155, "brand_name": "Alpha", "model_name": "E-Tec", "model_qualifier": "28", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 88.2, "comparative_hot_water_efficiency_pct": 75.2, "output_kw_max": 24.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.0055, "loss_factor_f1_kwh_per_day": 0.86242, "loss_factor_f2_kwh_per_day": 0.84011, "rejected_factor_f3_per_litre": 1e-05, "raw": ["018155", "000001", "0", "2020/Apr/09 15:51", "Alpha Therm", "Alpha", "E-Tec", "28", "3.027374", "2017", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "88.3", "88.2", "", "75.2", "", "2", "", "", "104", "1", "2", "10", "2", "0", "", "", "", "0", "", "", "", "", "2", "7.002", "0.082", "0.0055", "0.86242", "12.57", "0.112", "0.0045", "0.84011", "0.00001", "", "", "", "1005", "", "", "", "", "", "", "", "", "88.1", "97.6", "", "", "", "", "95.8"]} +{"pcdb_id": 18156, "brand_name": "Alpha", "model_name": "Evoke", "model_qualifier": "33", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 88.2, "comparative_hot_water_efficiency_pct": 74.7, "output_kw_max": 28.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.0085, "loss_factor_f1_kwh_per_day": 0.89436, "loss_factor_f2_kwh_per_day": 0.86958, "rejected_factor_f3_per_litre": 5e-05, "raw": ["018156", "000001", "0", "2020/Apr/09 15:49", "Alpha Therm", "Alpha", "Evoke", "33", "3.027377", "2017", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28", "28", "", "", "88.4", "88.2", "", "74.7", "", "2", "", "", "104", "1", "2", "12", "2", "0", "", "", "", "0", "", "", "", "", "2", "7.051", "0.095", "0.0085", "0.89436", "12.849", "0.125", "0.004", "0.86958", "0.00005", "", "", "", "1005", "", "", "", "", "", "", "", "", "88.2", "97.7", "", "", "", "", "95.9"]} +{"pcdb_id": 18157, "brand_name": "Alpha", "model_name": "Evoke", "model_qualifier": "28", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 88.2, "comparative_hot_water_efficiency_pct": 75.2, "output_kw_max": 24.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.0055, "loss_factor_f1_kwh_per_day": 0.86242, "loss_factor_f2_kwh_per_day": 0.84011, "rejected_factor_f3_per_litre": 1e-05, "raw": ["018157", "000001", "0", "2020/Apr/09 15:45", "Alpha Therm", "Alpha", "Evoke", "28", "3.027376", "2017", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "88.3", "88.2", "", "75.2", "", "2", "", "", "104", "1", "2", "10", "2", "0", "", "", "", "0", "", "", "", "", "2", "7.002", "0.082", "0.0055", "0.86242", "12.57", "0.112", "0.0045", "0.84011", "0.00001", "", "", "", "1005", "", "", "", "", "", "", "", "", "88.1", "97.6", "", "", "", "", "95.8"]} +{"pcdb_id": 18158, "brand_name": "Firebird Enviromax", "model_name": "Combipac HE", "model_qualifier": "26kW", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 81.7, "comparative_hot_water_efficiency_pct": 57.5, "output_kw_max": 26.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018158", "000047", "0", "2017/May/17 11:56", "Firebird Heating Solutions Ltd", "Firebird Enviromax", "Combipac HE", "26kW", "", "2017", "current", "4", "1", "2", "2", "0", "", "", "2", "3", "1", "26", "26", "", "", "89.1", "81.7", "", "57.5", "", "2", "", "", "202", "1", "1", "143", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "92.7", "96.9", "", "", "", "", "96.1"]} +{"pcdb_id": 18159, "brand_name": "Trianco", "model_name": "Combipac HE", "model_qualifier": "26", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 81.7, "comparative_hot_water_efficiency_pct": 57.5, "output_kw_max": 26.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018159", "000047", "0", "2017/May/17 11:56", "Firebird Heating Solutions Ltd", "Trianco", "Combipac HE", "26", "", "2017", "current", "4", "1", "2", "2", "0", "", "", "2", "3", "1", "26", "26", "", "", "89.1", "81.7", "", "57.5", "", "2", "", "", "202", "1", "1", "143", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "92.7", "96.9", "", "", "", "", "96.1"]} +{"pcdb_id": 18160, "brand_name": "Ravenheat", "model_name": "HE 98 (T)", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 55.9, "output_kw_max": 23.8, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018160", "000026", "0", "2017/Aug/09 16:15", "Ravenheat Manufacturing", "Ravenheat", "HE 98 (T)", "", "", "2016", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "23.8", "23.8", "", "", "88.1", "79.5", "", "55.9", "", "2", "", "", "104", "1", "2", "810", "5.2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "96.9", "", "", "", "", "95.2"]} +{"pcdb_id": 18161, "brand_name": "Firebird", "model_name": "Enviromax Heatpac", "model_qualifier": "C12/20kW", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 81.6, "comparative_hot_water_efficiency_pct": 59.6, "output_kw_max": 20.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018161", "000047", "0", "2017/Aug/14 15:49", "Firebird Heating Solutions Ltd", "Firebird", "Enviromax Heatpac", "C12/20kW", "", "2009", "current", "4", "1", "2", "1", "0", "", "", "2", "1", "1", "12", "20", "", "", "89.4", "81.6", "", "59.6", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "93.1", "97.4", "", "", "", "", "96.6"]} +{"pcdb_id": 18162, "brand_name": "Firebird", "model_name": "Enviromax Kitchen System", "model_qualifier": "C12/20kW", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 81.6, "comparative_hot_water_efficiency_pct": 59.6, "output_kw_max": 20.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018162", "000047", "0", "2017/Aug/14 15:49", "Firebird Heating Solutions Ltd", "Firebird", "Enviromax Kitchen System", "C12/20kW", "", "2009", "current", "4", "1", "1", "1", "0", "", "", "2", "2", "1", "12", "20", "", "", "89.4", "81.6", "", "59.6", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "93.1", "97.4", "", "", "", "", "96.6"]} +{"pcdb_id": 18163, "brand_name": "Firebird", "model_name": "Enviromax Popular", "model_qualifier": "C12/20kW", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 81.6, "comparative_hot_water_efficiency_pct": 59.6, "output_kw_max": 20.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018163", "000047", "0", "2017/Aug/14 15:50", "Firebird Heating Solutions Ltd", "Firebird", "Enviromax Popular", "C12/20kW", "", "2009", "current", "4", "1", "1", "1", "0", "", "", "2", "2", "1", "12", "20", "", "", "89.4", "81.6", "", "59.6", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "93.1", "97.4", "", "", "", "", "96.6"]} +{"pcdb_id": 18164, "brand_name": "Potterton", "model_name": "Ultra 12 System", "model_qualifier": "12", "winter_efficiency_pct": 89.6, "summer_efficiency_pct": 80.6, "comparative_hot_water_efficiency_pct": 58.8, "output_kw_max": 12.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018164", "000005", "0", "2017/Aug/07 13:34", "Baxi Heating", "Potterton", "Ultra 12 System", "12", "41-592-71", "2017", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "12", "12", "", "", "89.6", "80.6", "", "58.8", "", "2", "1", "", "102", "1", "2", "30", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.1", "100.3", "", "", "", "", "98.4"]} +{"pcdb_id": 18165, "brand_name": "Potterton", "model_name": "Ultra 12 System", "model_qualifier": "12", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 12.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018165", "000005", "0", "2017/Aug/07 13:34", "Baxi Heating", "Potterton", "Ultra 12 System", "12", "41-592-71", "2017", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "12", "12", "", "", "88.5", "79.5", "", "58.1", "", "2", "", "", "102", "1", "2", "30", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.1", "98.1", "", "", "", "", "96.2"]} +{"pcdb_id": 18166, "brand_name": "Potterton", "model_name": "Ultra 15 System", "model_qualifier": "15", "winter_efficiency_pct": 89.5, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 58.8, "output_kw_max": 15.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018166", "000005", "0", "2017/Aug/07 13:35", "Baxi Heating", "Potterton", "Ultra 15 System", "15", "41-592-72", "2017", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "15", "15", "", "", "89.5", "80.5", "", "58.8", "", "2", "1", "", "102", "1", "2", "30", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.0", "100.3", "", "", "", "", "98.3"]} +{"pcdb_id": 18167, "brand_name": "Potterton", "model_name": "Ultra 15 System", "model_qualifier": "15", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 15.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018167", "000005", "0", "2017/Aug/07 13:35", "Baxi Heating", "Potterton", "Ultra 15 System", "15", "41-592-72", "2017", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "15", "15", "", "", "88.5", "79.5", "", "58.1", "", "2", "", "", "102", "1", "2", "30", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "98.1", "", "", "", "", "96.2"]} +{"pcdb_id": 18168, "brand_name": "Potterton", "model_name": "Ultra 18 System", "model_qualifier": "18", "winter_efficiency_pct": 89.5, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 58.8, "output_kw_max": 18.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018168", "000005", "0", "2017/Aug/07 13:36", "Baxi Heating", "Potterton", "Ultra 18 System", "18", "41-592-73", "2017", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "18", "18", "", "", "89.5", "80.5", "", "58.8", "", "2", "1", "", "102", "1", "2", "30", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.0", "100.3", "", "", "", "", "98.3"]} +{"pcdb_id": 18169, "brand_name": "Potterton", "model_name": "Ultra 18 System", "model_qualifier": "18", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 18.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018169", "000005", "0", "2017/Aug/07 13:36", "Baxi Heating", "Potterton", "Ultra 18 System", "18", "41-592-73", "2017", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18", "18", "", "", "88.5", "79.5", "", "58.1", "", "2", "", "", "102", "1", "2", "30", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "98.1", "", "", "", "", "96.2"]} +{"pcdb_id": 18170, "brand_name": "Potterton", "model_name": "Ultra 24 System", "model_qualifier": "24", "winter_efficiency_pct": 89.5, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 58.8, "output_kw_max": 24.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018170", "000005", "0", "2017/Aug/07 13:37", "Baxi Heating", "Potterton", "Ultra 24 System", "24", "41-592-74", "2017", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "24", "24", "", "", "89.5", "80.5", "", "58.8", "", "2", "1", "", "102", "1", "2", "42", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.9", "100.2", "", "", "", "", "98.2"]} +{"pcdb_id": 18171, "brand_name": "Potterton", "model_name": "Ultra 24 System", "model_qualifier": "24", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 24.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018171", "000005", "0", "2017/Aug/07 13:37", "Baxi Heating", "Potterton", "Ultra 24 System", "24", "41-592-74", "2017", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24", "24", "", "", "88.5", "79.5", "", "58.1", "", "2", "", "", "102", "1", "2", "42", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "98.0", "", "", "", "", "96.1"]} +{"pcdb_id": 18172, "brand_name": "Potterton", "model_name": "Ultra 28 System", "model_qualifier": "28", "winter_efficiency_pct": 89.5, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 58.8, "output_kw_max": 28.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018172", "000005", "0", "2017/Aug/07 14:30", "Baxi Heating", "Potterton", "Ultra 28 System", "28", "41-592-75", "2017", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "28", "28", "", "", "89.5", "80.5", "", "58.8", "", "2", "1", "", "102", "1", "2", "47", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.9", "100.2", "", "", "", "", "98.2"]} +{"pcdb_id": 18173, "brand_name": "Potterton", "model_name": "Ultra 28 System", "model_qualifier": "28", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 28.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018173", "000005", "0", "2017/Aug/07 13:39", "Baxi Heating", "Potterton", "Ultra 28 System", "28", "41-592-75", "2017", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "28", "28", "", "", "88.5", "79.5", "", "58.1", "", "2", "", "", "102", "1", "2", "47", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "98.0", "", "", "", "", "96.1"]} +{"pcdb_id": 18174, "brand_name": "Firebird", "model_name": "Envirormax Kitchen", "model_qualifier": "C12/20kW", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 81.6, "comparative_hot_water_efficiency_pct": 59.6, "output_kw_max": 20.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018174", "000047", "0", "2017/Aug/14 15:50", "Firebird Heating Solutions Ltd", "Firebird", "Envirormax Kitchen", "C12/20kW", "", "2009", "current", "4", "1", "1", "1", "0", "", "", "2", "2", "1", "12", "20", "", "", "89.4", "81.6", "", "59.6", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "93.1", "97.4", "", "", "", "", "96.6"]} +{"pcdb_id": 18175, "brand_name": "Firebird", "model_name": "Enviromax Systempac", "model_qualifier": "C12/20kW", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 81.6, "comparative_hot_water_efficiency_pct": 59.6, "output_kw_max": 20.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018175", "000047", "0", "2017/Aug/14 15:50", "Firebird Heating Solutions Ltd", "Firebird", "Enviromax Systempac", "C12/20kW", "", "2009", "current", "4", "1", "2", "1", "0", "", "", "2", "1", "1", "12", "20", "", "", "89.4", "81.6", "", "59.6", "", "2", "", "", "201", "1", "1", "", "", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "93.1", "97.4", "", "", "", "", "96.6"]} +{"pcdb_id": 18176, "brand_name": "Potterton", "model_name": "Ultra 12 Heat", "model_qualifier": "12", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 13.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018176", "000005", "0", "2017/Aug/07 13:39", "Baxi Heating", "Potterton", "Ultra 12 Heat", "12", "41-592-56", "2017", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "13", "13", "", "", "88.5", "79.5", "", "58.1", "", "2", "", "", "102", "1", "2", "17", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "98.0", "", "", "", "", "96.1"]} +{"pcdb_id": 18177, "brand_name": "Potterton", "model_name": "Ultra 15 Heat", "model_qualifier": "15", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 16.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018177", "000005", "0", "2017/Aug/07 13:40", "Baxi Heating", "Potterton", "Ultra 15 Heat", "15", "41-592-57", "2017", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "16", "16", "", "", "88.5", "79.5", "", "58.1", "", "2", "", "", "102", "1", "2", "20", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.1", "98.0", "", "", "", "", "96.1"]} +{"pcdb_id": 18178, "brand_name": "Potterton", "model_name": "Ultra 18 Heat", "model_qualifier": "18", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 19.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018178", "000005", "0", "2017/Aug/07 13:40", "Baxi Heating", "Potterton", "Ultra 18 Heat", "18", "41-592-58", "2017", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "19", "19", "", "", "88.5", "79.5", "", "58.0", "", "2", "", "", "102", "1", "2", "23", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "98.0", "", "", "", "", "96.1"]} +{"pcdb_id": 18179, "brand_name": "Potterton", "model_name": "Ultra 21 Heat", "model_qualifier": "21", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 21.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018179", "000005", "0", "2017/Aug/07 13:40", "Baxi Heating", "Potterton", "Ultra 21 Heat", "21", "41-592-59", "2017", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "21", "21", "", "", "88.5", "79.5", "", "58.0", "", "2", "", "", "102", "1", "2", "25", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "98.0", "", "", "", "", "96.1"]} +{"pcdb_id": 18180, "brand_name": "Potterton", "model_name": "Ultra 24 Heat", "model_qualifier": "24", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 25.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018180", "000005", "0", "2017/Aug/07 13:41", "Baxi Heating", "Potterton", "Ultra 24 Heat", "24", "41-592-60", "2017", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "25", "25", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "33", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.7", "98.0", "", "", "", "", "96.1"]} +{"pcdb_id": 18181, "brand_name": "Grant", "model_name": "VORTEX", "model_qualifier": "BOILERHOUSE 15-21", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 20.7, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018181", "000048", "0", "2017/Dec/04 09:59", "Grant Engineering", "Grant", "VORTEX", "BOILERHOUSE 15-21", "", "2017", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "15", "20.7", "", "", "88.0", "80.2", "", "58.6", "", "2", "", "", "201", "1", "1", "113", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.5", "94.4", "", "", "", "", "93.9"]} +{"pcdb_id": 18182, "brand_name": "Grant", "model_name": "VORTEX", "model_qualifier": "BOILERHOUSE 21-26", "winter_efficiency_pct": 87.8, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 25.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018182", "000048", "0", "2017/Dec/04 10:00", "Grant Engineering", "Grant", "VORTEX", "BOILERHOUSE 21-26", "", "2017", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "21", "25.6", "", "", "87.8", "80.0", "", "58.4", "", "2", "", "", "201", "1", "1", "154", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.4", "94.4", "", "", "", "", "93.6"]} +{"pcdb_id": 18183, "brand_name": "Grant", "model_name": "VORTEX", "model_qualifier": "BOILERHOUSE 26-35", "winter_efficiency_pct": 87.5, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 34.7, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018183", "000048", "0", "2017/Dec/04 10:01", "Grant Engineering", "Grant", "VORTEX", "BOILERHOUSE 26-35", "", "2017", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "26", "34.7", "", "", "87.5", "79.7", "", "58.2", "", "2", "", "", "201", "1", "1", "146", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.3", "93.8", "", "", "", "", "93.1"]} +{"pcdb_id": 18184, "brand_name": "Trianco", "model_name": "TRO EVOLUTION 20 BH", "model_qualifier": "", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 81.4, "comparative_hot_water_efficiency_pct": 59.4, "output_kw_max": 19.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018184", "000062", "0", "2017/Nov/15 16:40", "TR Engineering Ltd", "Trianco", "TRO EVOLUTION 20 BH", "", "", "2017", "current", "4", "1", "1", "1", "0", "", "", "2", "2", "2", "19.0", "19.0", "", "", "89.2", "81.4", "", "59.4", "", "2", "", "", "201", "1", "1", "226", "1", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.1", "97.6", "", "", "", "", "96.4"]} +{"pcdb_id": 18185, "brand_name": "Trianco", "model_name": "TRO EVOLUTION 20 HEAT ONLY OUTDOOR", "model_qualifier": "", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 81.4, "comparative_hot_water_efficiency_pct": 59.4, "output_kw_max": 19.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018185", "000062", "0", "2017/Nov/15 16:45", "TR Engineering Ltd", "Trianco", "TRO EVOLUTION 20 HEAT ONLY OUTDOOR", "", "", "2017", "current", "4", "1", "2", "1", "0", "", "", "2", "1", "2", "19.0", "19.0", "", "", "89.2", "81.4", "", "59.4", "", "2", "", "", "201", "1", "1", "226", "1", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.1", "97.6", "", "", "", "", "96.4"]} +{"pcdb_id": 18186, "brand_name": "Trianco", "model_name": "EVOLUTION 20 INC DHW ACCU", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 82.7, "comparative_hot_water_efficiency_pct": 50.0, "output_kw_max": 19.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018186", "000062", "0", "2024/Jan/31 10:17", "TR Engineering Ltd", "Trianco", "EVOLUTION 20 INC DHW ACCU", "", "", "2017", "current", "4", "1", "1", "2", "0", "", "", "2", "2", "2", "19", "19", "", "", "88.8", "82.7", "", "50.0", "", "2", "", "", "203", "1", "1", "226", "1", "2", "1", "", "144", "0", "50", "2", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.5", "97.1", "", "", "", "", "95.8"]} +{"pcdb_id": 18187, "brand_name": "Trianco", "model_name": "TRO EVOLUTION 20 SYSTEM", "model_qualifier": "", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 81.4, "comparative_hot_water_efficiency_pct": 59.4, "output_kw_max": 19.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018187", "000062", "0", "2017/Nov/15 16:41", "TR Engineering Ltd", "Trianco", "TRO EVOLUTION 20 SYSTEM", "", "", "2017", "current", "4", "1", "1", "1", "0", "", "", "2", "2", "2", "19", "19", "", "", "89.2", "81.4", "", "59.4", "", "2", "", "", "201", "1", "1", "226", "1", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.1", "97.6", "", "", "", "", "96.4"]} +{"pcdb_id": 18188, "brand_name": "Trianco", "model_name": "TRO EVOLUTION 30 BH", "model_qualifier": "", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 81.4, "comparative_hot_water_efficiency_pct": 59.5, "output_kw_max": 30.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018188", "000062", "0", "2017/Nov/15 16:41", "TR Engineering Ltd", "Trianco", "TRO EVOLUTION 30 BH", "", "", "2017", "current", "4", "1", "1", "1", "0", "", "", "2", "2", "2", "30", "30", "", "", "89.2", "81.4", "", "59.5", "", "2", "", "", "201", "1", "1", "226", "1", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.4", "97.7", "", "", "", "", "96.5"]} +{"pcdb_id": 18189, "brand_name": "Trianco", "model_name": "TRO EVOLUTION 30 COMBI", "model_qualifier": "", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 81.8, "comparative_hot_water_efficiency_pct": 57.6, "output_kw_max": 30.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018189", "000062", "0", "2017/Nov/15 16:42", "TR Engineering Ltd", "Trianco", "TRO EVOLUTION 30 COMBI", "", "", "2017", "current", "4", "1", "1", "2", "0", "", "", "2", "2", "2", "30", "30", "", "", "89.2", "81.8", "", "57.6", "", "2", "", "", "202", "1", "1", "226", "1", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.4", "97.7", "", "", "", "", "96.5"]} +{"pcdb_id": 18190, "brand_name": "Trianco", "model_name": "TRO EVOLUTION 30 COMBI OUTDOOR", "model_qualifier": "", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 81.8, "comparative_hot_water_efficiency_pct": 57.6, "output_kw_max": 30.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018190", "000062", "0", "2017/Nov/15 16:42", "TR Engineering Ltd", "Trianco", "TRO EVOLUTION 30 COMBI OUTDOOR", "", "", "2017", "current", "4", "1", "2", "2", "0", "", "", "2", "1", "2", "30", "30", "", "", "89.2", "81.8", "", "57.6", "", "2", "", "", "202", "1", "1", "226", "1", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.4", "97.7", "", "", "", "", "96.5"]} +{"pcdb_id": 18191, "brand_name": "Trianco", "model_name": "TRO EVOLUTION 30 HEAT ONLY OUTDOOR", "model_qualifier": "", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 81.4, "comparative_hot_water_efficiency_pct": 59.5, "output_kw_max": 30.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018191", "000062", "0", "2017/Nov/15 16:43", "TR Engineering Ltd", "Trianco", "TRO EVOLUTION 30 HEAT ONLY OUTDOOR", "", "", "2017", "current", "4", "1", "2", "1", "0", "", "", "2", "1", "2", "30", "30", "", "", "89.2", "81.4", "", "59.5", "", "2", "", "", "201", "1", "1", "226", "1", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.4", "97.7", "", "", "", "", "96.5"]} +{"pcdb_id": 18192, "brand_name": "Trianco", "model_name": "TRO EVOLUTION 30 INC DHW ACCU", "model_qualifier": "", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 82.8, "comparative_hot_water_efficiency_pct": 49.6, "output_kw_max": 30.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018192", "000062", "0", "2024/Jan/31 10:17", "TR Engineering Ltd", "Trianco", "TRO EVOLUTION 30 INC DHW ACCU", "", "", "2017", "current", "4", "1", "1", "2", "0", "", "", "2", "2", "2", "30", "30", "", "", "88.9", "82.8", "", "49.6", "", "2", "", "", "203", "1", "1", "226", "1", "2", "1", "0", "149.2", "0", "50", "2", "65", "135", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.8", "97.1", "", "", "", "", "95.9"]} +{"pcdb_id": 18193, "brand_name": "Trianco", "model_name": "TRO EVOLUTION 30 SYSTEM", "model_qualifier": "", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 81.4, "comparative_hot_water_efficiency_pct": 59.5, "output_kw_max": 30.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018193", "000062", "0", "2017/Nov/15 16:43", "TR Engineering Ltd", "Trianco", "TRO EVOLUTION 30 SYSTEM", "", "", "2017", "current", "4", "1", "1", "1", "0", "", "", "2", "2", "2", "30", "30", "", "", "89.2", "81.4", "", "59.5", "", "2", "", "", "201", "1", "1", "226", "1", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.4", "97.7", "", "", "", "", "96.5"]} +{"pcdb_id": 18194, "brand_name": "Trianco", "model_name": "TRO EVOLUTION 40 COMBI", "model_qualifier": "", "winter_efficiency_pct": 89.3, "summer_efficiency_pct": 81.9, "comparative_hot_water_efficiency_pct": 57.6, "output_kw_max": 40.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018194", "000062", "0", "2017/Nov/15 16:43", "TR Engineering Ltd", "Trianco", "TRO EVOLUTION 40 COMBI", "", "", "2017", "current", "4", "1", "1", "2", "0", "", "", "2", "2", "2", "40", "40", "", "", "89.3", "81.9", "", "57.6", "", "2", "", "", "202", "1", "1", "226", "1", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.7", "97.8", "", "", "", "", "96.7"]} +{"pcdb_id": 18195, "brand_name": "Trianco", "model_name": "TRO EVOLUTION 40 COMBI OUTDOOR", "model_qualifier": "", "winter_efficiency_pct": 89.3, "summer_efficiency_pct": 81.9, "comparative_hot_water_efficiency_pct": 57.6, "output_kw_max": 40.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018195", "000062", "0", "2017/Nov/15 16:43", "TR Engineering Ltd", "Trianco", "TRO EVOLUTION 40 COMBI OUTDOOR", "", "", "2017", "current", "4", "1", "2", "2", "0", "", "", "2", "1", "2", "40", "40", "", "", "89.3", "81.9", "", "57.6", "", "2", "", "", "202", "1", "1", "226", "1", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.7", "97.8", "", "", "", "", "96.7"]} +{"pcdb_id": 18196, "brand_name": "Trianco", "model_name": "TRO EVOLUTION 40 HEAT ONLY OUTDOOR", "model_qualifier": "", "winter_efficiency_pct": 89.3, "summer_efficiency_pct": 81.5, "comparative_hot_water_efficiency_pct": 59.6, "output_kw_max": 40.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018196", "000062", "0", "2017/Nov/15 16:43", "TR Engineering Ltd", "Trianco", "TRO EVOLUTION 40 HEAT ONLY OUTDOOR", "", "", "2017", "current", "4", "1", "2", "1", "0", "", "", "2", "1", "2", "40", "40", "", "", "89.3", "81.5", "", "59.6", "", "2", "", "", "201", "1", "1", "226", "1", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.7", "97.8", "", "", "", "", "96.7"]} +{"pcdb_id": 18197, "brand_name": "Trianco", "model_name": "TRO EVOLUTION 40 INC DHW ACCU", "model_qualifier": "", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 82.9, "comparative_hot_water_efficiency_pct": 49.3, "output_kw_max": 40.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018197", "000062", "0", "2024/Jan/31 10:17", "TR Engineering Ltd", "Trianco", "TRO EVOLUTION 40 INC DHW ACCU", "", "", "2017", "current", "4", "1", "1", "2", "0", "", "", "2", "2", "2", "40", "40", "", "", "89.0", "82.9", "", "49.3", "", "2", "", "", "203", "1", "1", "226", "1", "2", "1", "0", "153.2", "0", "50", "2", "65", "170", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.2", "97.2", "", "", "", "", "96.0"]} +{"pcdb_id": 18198, "brand_name": "Trianco", "model_name": "TRO EVOLUTION 40 SYSTEM", "model_qualifier": "", "winter_efficiency_pct": 89.3, "summer_efficiency_pct": 81.5, "comparative_hot_water_efficiency_pct": 59.6, "output_kw_max": 40.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018198", "000062", "0", "2017/Nov/15 16:44", "TR Engineering Ltd", "Trianco", "TRO EVOLUTION 40 SYSTEM", "", "", "2017", "current", "4", "1", "1", "1", "0", "", "", "2", "2", "2", "40", "40", "", "", "89.3", "81.5", "", "59.6", "", "2", "", "", "201", "1", "1", "226", "1", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.7", "97.8", "", "", "", "", "96.7"]} +{"pcdb_id": 18199, "brand_name": "EUROTERM", "model_name": "E27 PLUS", "model_qualifier": "", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 86.7, "comparative_hot_water_efficiency_pct": 73.8, "output_kw_max": 24.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.016, "loss_factor_f1_kwh_per_day": 0.92714, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018199", "000097", "0", "2017/Nov/08 09:59", "Ferroli", "EUROTERM", "E27 PLUS", "", "47-267-66", "2017", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.5", "24.5", "", "", "88.9", "86.7", "", "73.8", "", "2", "", "", "104", "1", "2", "39", "3", "0", "", "", "", "0", "", "", "", "", "1", "7.133", "0.084", "0.016", "0.92714", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.1", "98.9", "", "", "", "", "96.9"]} +{"pcdb_id": 18200, "brand_name": "EUROTERM", "model_name": "E32 PLUS", "model_qualifier": "", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 86.7, "comparative_hot_water_efficiency_pct": 72.4, "output_kw_max": 28.9, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0085, "loss_factor_f1_kwh_per_day": 1.10862, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018200", "000097", "0", "2017/Nov/08 09:59", "Ferroli", "EUROTERM", "E32 PLUS", "", "47-267-67", "2017", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28.9", "28.9", "", "", "88.9", "86.7", "", "72.4", "", "2", "", "", "104", "1", "2", "54", "3", "0", "", "", "", "0", "", "", "", "", "1", "7.276", "0.087", "0.0085", "1.10862", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.1", "98.9", "", "", "", "", "96.9"]} +{"pcdb_id": 18201, "brand_name": "Potterton", "model_name": "Assure", "model_qualifier": "15 System", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 15.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018201", "000005", "0", "2019/Jan/10 14:17", "Baxi Heating", "Potterton", "Assure", "15 System", "41-592-54", "2017", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "15", "15", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "57", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "88.2", "97.8", "", "", "", "", "95.9"]} +{"pcdb_id": 18202, "brand_name": "Potterton", "model_name": "Assure", "model_qualifier": "18 System", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 18.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018202", "000005", "0", "2019/Jan/10 14:18", "Baxi Heating", "Potterton", "Assure", "18 System", "41-592-55", "2017", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18", "18", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "65", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "88.2", "97.8", "", "", "", "", "96.0"]} +{"pcdb_id": 18203, "brand_name": "Potterton", "model_name": "Assure", "model_qualifier": "25 Combi", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 86.7, "comparative_hot_water_efficiency_pct": 80.2, "output_kw_max": 20.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0004, "loss_factor_f1_kwh_per_day": 0.46731, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018203", "000005", "0", "2020/Jan/22 13:16", "Baxi Heating", "Potterton", "Assure", "25 Combi", "47-393-58", "2017", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "20", "20", "", "", "88.4", "86.7", "", "80.2", "", "2", "", "", "104", "1", "2", "68", "3", "0", "", "", "", "0", "", "", "", "", "1", "6.563", "0.102", "0.0004", "0.46731", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "88.0", "97.8", "", "", "", "", "95.9"]} +{"pcdb_id": 18204, "brand_name": "Potterton", "model_name": "Assure", "model_qualifier": "30 Combi", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 86.7, "comparative_hot_water_efficiency_pct": 79.3, "output_kw_max": 25.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0009, "loss_factor_f1_kwh_per_day": 0.54193, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018204", "000005", "0", "2020/Jan/22 13:16", "Baxi Heating", "Potterton", "Assure", "30 Combi", "47-393-59", "2017", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "25", "25", "", "", "88.4", "86.7", "", "79.3", "", "2", "", "", "104", "1", "2", "78", "3", "0", "", "", "", "0", "", "", "", "", "1", "6.641", "0.105", "0.0009", "0.54193", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "88.1", "97.8", "", "", "", "", "96.0"]} +{"pcdb_id": 18205, "brand_name": "Potterton", "model_name": "Assure", "model_qualifier": "13 Heat", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 13.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018205", "000005", "0", "2017/Aug/16 11:02", "Baxi Heating", "Potterton", "Assure", "13 Heat", "41-592-66", "2017", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "13", "13", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "17", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.3", "98.0", "", "", "", "", "96.0"]} +{"pcdb_id": 18206, "brand_name": "Potterton", "model_name": "Assure", "model_qualifier": "16 Heat", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 16.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018206", "000005", "0", "2017/Aug/16 11:03", "Baxi Heating", "Potterton", "Assure", "16 Heat", "41-592-67", "2017", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "16", "16", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "17", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.3", "98.0", "", "", "", "", "96.0"]} +{"pcdb_id": 18207, "brand_name": "Potterton", "model_name": "Assure", "model_qualifier": "19 Heat", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 19.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018207", "000005", "0", "2017/Aug/16 11:03", "Baxi Heating", "Potterton", "Assure", "19 Heat", "41-592-68", "2017", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "19", "19", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "23", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.3", "98.0", "", "", "", "", "96.0"]} +{"pcdb_id": 18208, "brand_name": "Potterton", "model_name": "Assure", "model_qualifier": "25 Heat", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 25.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018208", "000005", "0", "2017/Aug/16 11:03", "Baxi Heating", "Potterton", "Assure", "25 Heat", "41-592-69", "2017", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "25", "25", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "33", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.3", "98.0", "", "", "", "", "96.0"]} +{"pcdb_id": 18209, "brand_name": "Potterton", "model_name": "Assure", "model_qualifier": "30 Heat", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 30.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018209", "000005", "0", "2017/Aug/16 11:03", "Baxi Heating", "Potterton", "Assure", "30 Heat", "41-592-70", "2017", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "30", "30", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "44", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.3", "98.0", "", "", "", "", "96.0"]} +{"pcdb_id": 18210, "brand_name": "Vaillant", "model_name": "ecoTEC plus 612", "model_qualifier": "VU 126/5-5 (H-GB) R6", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 12.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018210", "000031", "0", "2018/Mar/21 08:22", "Vaillant", "Vaillant", "ecoTEC plus 612", "VU 126/5-5 (H-GB) R6", "41-694-20", "2017", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "12.4", "12.4", "", "", "88.6", "79.6", "", "58.1", "", "2", "", "", "102", "1", "2", "22", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0045", "", "", "", "", "", "", "", "", "88.8", "97.8", "", "", "", "", "96.1"]} +{"pcdb_id": 18211, "brand_name": "Vaillant", "model_name": "ecoTEC plus 615", "model_qualifier": "VU 156/5-5 (H-GB) R6", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 15.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018211", "000031", "0", "2018/Mar/19 11:25", "Vaillant", "Vaillant", "ecoTEC plus 615", "VU 156/5-5 (H-GB) R6", "41-694-21", "2017", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "15.5", "15.5", "", "", "88.5", "79.5", "", "58.1", "", "2", "", "", "102", "1", "2", "28", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0045", "", "", "", "", "", "", "", "", "88.6", "97.8", "", "", "", "", "96.1"]} +{"pcdb_id": 18212, "brand_name": "Vaillant", "model_name": "ecoTEC plus 618", "model_qualifier": "VU 186/5-5 (H-GB) R6", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 18.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018212", "000031", "0", "2019/Jan/18 11:52", "Vaillant", "Vaillant", "ecoTEC plus 618", "VU 186/5-5 (H-GB) R6", "41-694-22", "2017", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18.6", "18.6", "", "", "88.9", "79.9", "", "58.3", "", "2", "", "", "102", "1", "2", "29", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0045", "", "", "", "", "", "", "", "", "88.7", "98.7", "", "", "", "", "96.8"]} +{"pcdb_id": 18213, "brand_name": "Vaillant", "model_name": "ecoTEC plus 618", "model_qualifier": "VU 186/5-5 (P-GB) R6", "winter_efficiency_pct": 89.9, "summer_efficiency_pct": 80.9, "comparative_hot_water_efficiency_pct": 59.1, "output_kw_max": 18.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018213", "000031", "0", "2018/Mar/19 11:25", "Vaillant", "Vaillant", "ecoTEC plus 618", "VU 186/5-5 (P-GB) R6", "41-694-23", "2017", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "18.6", "18.6", "", "", "89.9", "80.9", "", "59.1", "", "2", "0", "", "102", "1", "2", "25", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0045", "", "", "", "", "", "", "", "", "90.4", "98.5", "", "", "", "", "97.0"]} +{"pcdb_id": 18214, "brand_name": "Vaillant", "model_name": "ecoTEC plus 624", "model_qualifier": "VU 246/5-5 (H-GB) R6", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 24.7, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018214", "000031", "0", "2018/Aug/20 09:30", "Vaillant", "Vaillant", "ecoTEC plus 624", "VU 246/5-5 (H-GB) R6", "41-694-24", "2017", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24.7", "24.7", "", "", "88.9", "79.9", "", "58.4", "", "2", "", "", "102", "1", "2", "25", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0045", "", "", "", "", "", "", "", "", "88.5", "98.9", "", "", "", "", "96.9"]} +{"pcdb_id": 18215, "brand_name": "Vaillant", "model_name": "ecoTEC plus 630", "model_qualifier": "VU 306/5-5 (H-GB) R6", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 30.9, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018215", "000031", "0", "2018/Aug/20 09:31", "Vaillant", "Vaillant", "ecoTEC plus 630", "VU 306/5-5 (H-GB) R6", "41-694-25", "2017", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "30.9", "30.9", "", "", "88.8", "79.8", "", "58.3", "", "2", "", "", "102", "1", "2", "33", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0045", "", "", "", "", "", "", "", "", "88.5", "98.6", "", "", "", "", "96.7"]} +{"pcdb_id": 18216, "brand_name": "Vaillant", "model_name": "ecoTEC plus 630", "model_qualifier": "VU 306/5-5 (P-GB) R6", "winter_efficiency_pct": 90.0, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 59.2, "output_kw_max": 30.9, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018216", "000031", "0", "2018/Mar/19 11:26", "Vaillant", "Vaillant", "ecoTEC plus 630", "VU 306/5-5 (P-GB) R6", "41-694-26", "2017", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "30.9", "30.9", "", "", "90.0", "81.0", "", "59.2", "", "2", "0", "", "102", "1", "2", "32", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0045", "", "", "", "", "", "", "", "", "90.2", "98.8", "", "", "", "", "97.2"]} +{"pcdb_id": 18217, "brand_name": "Vaillant", "model_name": "ecoTEC plus 637", "model_qualifier": "VU 386/5-5 (H-GB) R6", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 38.1, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018217", "000031", "0", "2018/Aug/20 09:31", "Vaillant", "Vaillant", "ecoTEC plus 637", "VU 386/5-5 (H-GB) R6", "41-694-27", "2017", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "38.1", "38.1", "", "", "88.8", "79.8", "", "58.3", "", "2", "", "", "102", "1", "2", "45", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0045", "", "", "", "", "", "", "", "", "88.7", "98.5", "", "", "", "", "96.6"]} +{"pcdb_id": 18218, "brand_name": "Vaillant", "model_name": "ecoTEC plus 825", "model_qualifier": "VUW 196/5-5 (H-GB) R6", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 56.5, "output_kw_max": 19.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018218", "000031", "0", "2019/Jan/18 11:51", "Vaillant", "Vaillant", "ecoTEC plus 825", "VUW 196/5-5 (H-GB) R6", "47-044-83", "2017", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "19.6", "19.6", "", "", "88.9", "80.3", "", "56.5", "", "2", "", "", "104", "1", "2", "29", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0045", "", "", "", "", "", "", "", "", "88.7", "98.7", "", "", "", "", "96.8"]} +{"pcdb_id": 18219, "brand_name": "Vaillant", "model_name": "ecoTEC plus 832", "model_qualifier": "VUW 246/5-5 (H-GB) R6", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 56.5, "output_kw_max": 24.7, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018219", "000031", "0", "2019/Jan/18 11:51", "Vaillant", "Vaillant", "ecoTEC plus 832", "VUW 246/5-5 (H-GB) R6", "47-044-84", "2017", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.7", "24.7", "", "", "88.9", "80.3", "", "56.5", "", "2", "", "", "104", "1", "2", "25", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0045", "", "", "", "", "", "", "", "", "88.5", "98.9", "", "", "", "", "96.9"]} +{"pcdb_id": 18220, "brand_name": "Vaillant", "model_name": "ecoTEC plus 832", "model_qualifier": "VUW 246/5-5 (P-GB) R6", "winter_efficiency_pct": 89.9, "summer_efficiency_pct": 81.3, "comparative_hot_water_efficiency_pct": 57.2, "output_kw_max": 24.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018220", "000031", "0", "2018/Mar/19 11:26", "Vaillant", "Vaillant", "ecoTEC plus 832", "VUW 246/5-5 (P-GB) R6", "47-044-85", "2017", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "89.9", "81.3", "", "57.2", "", "2", "0", "", "104", "1", "2", "39", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0045", "", "", "", "", "", "", "", "", "90.4", "98.5", "", "", "", "", "96.9"]} +{"pcdb_id": 18221, "brand_name": "Vaillant", "model_name": "ecoTEC plus 835", "model_qualifier": "VUW 306/5-5 (H-GB) R6", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 56.4, "output_kw_max": 30.9, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018221", "000031", "0", "2019/Jan/18 11:52", "Vaillant", "Vaillant", "ecoTEC plus 835", "VUW 306/5-5 (H-GB) R6", "47-044-82", "2017", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "30.9", "30.9", "", "", "88.8", "80.2", "", "56.4", "", "2", "", "", "104", "1", "2", "33", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0045", "", "", "", "", "", "", "", "", "88.5", "98.6", "", "", "", "", "96.7"]} +{"pcdb_id": 18222, "brand_name": "Vaillant", "model_name": "ecoTEC plus 838", "model_qualifier": "VUW 286/5-5 (H-GB) R6", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 56.4, "output_kw_max": 28.9, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018222", "000031", "0", "2019/Jan/18 11:52", "Vaillant", "Vaillant", "ecoTEC plus 838", "VUW 286/5-5 (H-GB) R6", "47-044-86", "2017", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28.9", "28.9", "", "", "88.8", "80.2", "", "56.4", "", "2", "", "", "104", "1", "2", "29", "3", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0045", "", "", "", "", "", "", "", "", "88.7", "98.6", "", "", "", "", "96.7"]} +{"pcdb_id": 18223, "brand_name": "Vaillant", "model_name": "ecoTEC plus 938", "model_qualifier": "VUI 286/5-5 (H-GB) R6", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 56.4, "output_kw_max": 28.9, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018223", "000031", "0", "2019/Mar/11 09:21", "Vaillant", "Vaillant", "ecoTEC plus 938", "VUI 286/5-5 (H-GB) R6", "47-044-87", "2017", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28.9", "28.9", "", "", "88.8", "80.2", "", "56.4", "", "2", "", "", "104", "1", "2", "28", "3", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0045", "", "", "", "", "", "", "", "", "88.7", "98.6", "", "", "", "", "96.7"]} +{"pcdb_id": 18224, "brand_name": "Vaillant", "model_name": "ecoTEC pro 24", "model_qualifier": "VUW 246/5-3 (H-GB) R6", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 56.5, "output_kw_max": 23.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018224", "000031", "0", "2019/Jan/18 11:52", "Vaillant", "Vaillant", "ecoTEC pro 24", "VUW 246/5-3 (H-GB) R6", "47-044-88", "2017", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "23.5", "23.5", "", "", "88.9", "80.3", "", "56.5", "", "2", "", "", "104", "1", "2", "32", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0045", "", "", "", "", "", "", "", "", "88.7", "98.7", "", "", "", "", "96.8"]} +{"pcdb_id": 18225, "brand_name": "Vaillant", "model_name": "ecoTEC pro 28", "model_qualifier": "VUW 286/5-3 (H-GB) R6", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 56.5, "output_kw_max": 24.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018225", "000031", "0", "2019/Jan/18 11:52", "Vaillant", "Vaillant", "ecoTEC pro 28", "VUW 286/5-3 (H-GB) R6", "47-044-89", "2017", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.5", "24.5", "", "", "88.9", "80.3", "", "56.5", "", "2", "", "", "104", "1", "2", "32", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0045", "", "", "", "", "", "", "", "", "88.7", "98.7", "", "", "", "", "96.8"]} +{"pcdb_id": 18226, "brand_name": "Vaillant", "model_name": "ecoTEC pro 28", "model_qualifier": "VUW 286/5-3 (P-GB)", "winter_efficiency_pct": 90.1, "summer_efficiency_pct": 81.5, "comparative_hot_water_efficiency_pct": 57.3, "output_kw_max": 24.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018226", "000031", "0", "2018/Mar/19 11:27", "Vaillant", "Vaillant", "ecoTEC pro 28", "VUW 286/5-3 (P-GB)", "47-044-89", "2017", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "90.1", "81.5", "", "57.3", "", "2", "0", "", "104", "1", "2", "32", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0045", "", "", "", "", "", "", "", "", "90.4", "99.1", "", "", "", "", "97.4"]} +{"pcdb_id": 18227, "brand_name": "Glow-worm", "model_name": "EASICOM 3", "model_qualifier": "24c-A (H-GB)", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.4, "comparative_hot_water_efficiency_pct": 56.6, "output_kw_max": 20.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018227", "000207", "0", "2018/Mar/19 11:40", "Glow-worm", "Glow-worm", "EASICOM 3", "24c-A (H-GB)", "47-019-50", "2017", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "20.4", "20.4", "", "", "89.0", "80.4", "", "56.6", "", "2", "", "", "104", "1", "2", "27", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0085", "", "", "", "", "", "", "", "", "89.1", "98.9", "", "", "", "", "97.1"]} +{"pcdb_id": 18228, "brand_name": "Glow-worm", "model_name": "EASICOM 3", "model_qualifier": "28c-A (H-GB)", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.4, "comparative_hot_water_efficiency_pct": 56.5, "output_kw_max": 25.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018228", "000207", "0", "2019/May/09 11:58", "Glow-worm", "Glow-worm", "EASICOM 3", "28c-A (H-GB)", "47-019-51", "2017", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "25", "25", "", "", "89.0", "80.4", "", "56.5", "", "2", "", "", "104", "1", "2", "29", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0085", "", "", "", "", "", "", "", "", "89.0", "98.8", "", "", "", "", "97.0"]} +{"pcdb_id": 18229, "brand_name": "Glow-worm", "model_name": "ULTIMATE 3", "model_qualifier": "30c-A (H-GB)", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.4, "comparative_hot_water_efficiency_pct": 56.5, "output_kw_max": 25.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018229", "000207", "0", "2019/May/09 12:01", "Glow-worm", "Glow-worm", "ULTIMATE 3", "30c-A (H-GB)", "47-019-55", "2017", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "25", "25", "", "", "89.0", "80.4", "", "56.5", "", "2", "", "", "104", "1", "2", "29", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0085", "", "", "", "", "", "", "", "", "89.0", "98.8", "", "", "", "", "97.0"]} +{"pcdb_id": 18230, "brand_name": "Glow-worm", "model_name": "ULTIMATE 3", "model_qualifier": "35c-A (H-GB)", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 56.6, "output_kw_max": 25.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018230", "000207", "0", "2019/May/09 12:02", "Glow-worm", "Glow-worm", "ULTIMATE 3", "35c-A (H-GB)", "47-019-57", "2017", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "25", "25", "", "", "89.1", "80.5", "", "56.6", "", "2", "", "", "104", "1", "2", "27", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0085", "", "", "", "", "", "", "", "", "89.5", "99.0", "", "", "", "", "97.2"]} +{"pcdb_id": 18231, "brand_name": "Glow-worm", "model_name": "ULTIMATE 3", "model_qualifier": "25s-A (H-GB)", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 25.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018231", "000207", "0", "2019/May/09 12:04", "Glow-worm", "Glow-worm", "ULTIMATE 3", "25s-A (H-GB)", "41-019-51", "2017", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "25", "25", "", "", "89.0", "80.0", "", "58.4", "", "2", "", "", "102", "1", "2", "29", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0085", "", "", "", "", "", "", "", "", "89.0", "98.8", "", "", "", "", "97.0"]} +{"pcdb_id": 18232, "brand_name": "Glow-worm", "model_name": "ULTIMATE 3", "model_qualifier": "25r-A (H-GB)", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 25.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018232", "000207", "0", "2022/May/10 10:35", "Glow-worm", "Glow-worm", "ULTIMATE 3", "25r-A (H-GB)", "41-019-52", "2017", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "25.2", "25.2", "", "", "89.0", "80.0", "", "58.4", "", "2", "", "", "102", "1", "2", "29", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0085", "", "", "", "", "", "", "", "", "89.0", "98.8", "", "", "", "", "97.0"]} +{"pcdb_id": 18233, "brand_name": "Glow-worm", "model_name": "BETACOM 4", "model_qualifier": "24c-A (H-GB)", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.4, "comparative_hot_water_efficiency_pct": 56.6, "output_kw_max": 20.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018233", "000207", "0", "2018/Mar/19 11:40", "Glow-worm", "Glow-worm", "BETACOM 4", "24c-A (H-GB)", "47-019-52", "2017", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "20.4", "20.4", "", "", "89.0", "80.4", "", "56.6", "", "2", "", "", "104", "1", "2", "27", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0085", "", "", "", "", "", "", "", "", "89.1", "98.9", "", "", "", "", "97.1"]} +{"pcdb_id": 18234, "brand_name": "Glow-worm", "model_name": "BETACOM 4", "model_qualifier": "30c-A (H-GB)", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.4, "comparative_hot_water_efficiency_pct": 56.5, "output_kw_max": 25.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018234", "000207", "0", "2019/May/09 12:07", "Glow-worm", "Glow-worm", "BETACOM 4", "30c-A (H-GB)", "47-019-53", "2017", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "25", "25", "", "", "89.0", "80.4", "", "56.5", "", "2", "", "", "104", "1", "2", "29", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0085", "", "", "", "", "", "", "", "", "89.0", "98.8", "", "", "", "", "97.0"]} +{"pcdb_id": 18236, "brand_name": "Ariston", "model_name": "CLAS SYSTEM ONE 18", "model_qualifier": "", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 17.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018236", "000080", "0", "2018/Apr/09 11:33", "Ariston Thermo S.p.A", "Ariston", "CLAS SYSTEM ONE 18", "", "3301046", "2017", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "17.6", "17.6", "", "", "88.7", "79.7", "", "58.2", "", "2", "", "", "102", "1", "2", "24", "4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0805", "", "", "", "", "", "", "", "", "87.9", "98.6", "", "", "", "", "96.5"]} +{"pcdb_id": 18237, "brand_name": "Ariston", "model_name": "CLAS ONE 24", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 86.6, "comparative_hot_water_efficiency_pct": 75.2, "output_kw_max": 21.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.003, "loss_factor_f1_kwh_per_day": 0.87401, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018237", "000080", "0", "2020/Jan/22 13:16", "Ariston Thermo S.p.A", "Ariston", "CLAS ONE 24", "", "3301043", "2017", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "21.4", "21.4", "", "", "88.8", "86.6", "", "75.2", "", "2", "", "", "104", "1", "2", "30", "4", "0", "", "", "", "0", "", "", "", "", "1", "7.006", "0.121", "0.003", "0.87401", "", "", "", "", "", "", "", "", "0805", "", "", "", "", "", "", "", "", "87.8", "98.9", "", "", "", "", "96.8"]} +{"pcdb_id": 18238, "brand_name": "Ariston", "model_name": "CLAS SYSTEM ONE 24", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 21.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018238", "000080", "0", "2018/Apr/09 11:36", "Ariston Thermo S.p.A", "Ariston", "CLAS SYSTEM ONE 24", "", "3301047", "2017", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "21.4", "21.4", "", "", "88.8", "79.8", "", "58.3", "", "2", "", "", "102", "1", "2", "30", "4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0805", "", "", "", "", "", "", "", "", "87.8", "98.9", "", "", "", "", "96.8"]} +{"pcdb_id": 18239, "brand_name": "Ariston", "model_name": "CLAS NET ONE 24", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 86.6, "comparative_hot_water_efficiency_pct": 75.2, "output_kw_max": 21.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.003, "loss_factor_f1_kwh_per_day": 0.87401, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018239", "000080", "0", "2020/Jan/22 13:16", "Ariston Thermo S.p.A", "Ariston", "CLAS NET ONE 24", "", "3301049", "2017", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "21.4", "21.4", "", "", "88.8", "86.6", "", "75.2", "", "2", "", "", "104", "1", "2", "30", "4", "0", "", "", "", "0", "", "", "", "", "1", "7.006", "0.121", "0.003", "0.87401", "", "", "", "", "", "", "", "", "0805", "", "", "", "", "", "", "", "", "87.8", "98.9", "", "", "", "", "96.8"]} +{"pcdb_id": 18240, "brand_name": "Ariston", "model_name": "E-COMBI ONE 24", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 86.6, "comparative_hot_water_efficiency_pct": 75.2, "output_kw_max": 21.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.003, "loss_factor_f1_kwh_per_day": 0.87401, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018240", "000080", "0", "2020/Jan/22 13:17", "Ariston Thermo S.p.A", "Ariston", "E-COMBI ONE 24", "", "3301131", "2017", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "21.4", "21.4", "", "", "88.8", "86.6", "", "75.2", "", "2", "", "", "104", "1", "2", "30", "4", "0", "", "", "", "0", "", "", "", "", "1", "7.006", "0.121", "0.003", "0.87401", "", "", "", "", "", "", "", "", "0805", "", "", "", "", "", "", "", "", "87.8", "98.9", "", "", "", "", "96.8"]} +{"pcdb_id": 18241, "brand_name": "Ariston", "model_name": "E-SYSTEM ONE 24", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 21.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018241", "000080", "0", "2018/Apr/09 11:41", "Ariston Thermo S.p.A", "Ariston", "E-SYSTEM ONE 24", "", "3301056", "2017", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "21.4", "21.4", "", "", "88.8", "79.8", "", "58.3", "", "2", "", "", "102", "1", "2", "30", "4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0805", "", "", "", "", "", "", "", "", "87.8", "98.9", "", "", "", "", "96.8"]} +{"pcdb_id": 18242, "brand_name": "Ariston", "model_name": "CLAS ONE 30", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 86.8, "comparative_hot_water_efficiency_pct": 72.7, "output_kw_max": 27.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.007, "loss_factor_f1_kwh_per_day": 1.08414, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018242", "000080", "0", "2020/Jan/22 13:17", "Ariston Thermo S.p.A", "Ariston", "CLAS ONE 30", "", "3301044", "2017", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "27.4", "27.4", "", "", "88.8", "86.8", "", "72.7", "", "2", "", "", "104", "1", "2", "39", "4", "0", "", "", "", "0", "", "", "", "", "1", "7.239", "0.14", "0.007", "1.08414", "", "", "", "", "", "", "", "", "0805", "", "", "", "", "", "", "", "", "88.2", "98.7", "", "", "", "", "96.7"]} +{"pcdb_id": 18243, "brand_name": "Ariston", "model_name": "CLAS NET ONE 30", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 86.8, "comparative_hot_water_efficiency_pct": 72.7, "output_kw_max": 27.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.007, "loss_factor_f1_kwh_per_day": 1.08414, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018243", "000080", "0", "2020/Jan/22 13:17", "Ariston Thermo S.p.A", "Ariston", "CLAS NET ONE 30", "", "3301050", "2017", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "27.4", "27.4", "", "", "88.8", "86.8", "", "72.7", "", "2", "", "", "104", "1", "2", "39", "4", "0", "", "", "", "0", "", "", "", "", "1", "7.239", "0.14", "0.007", "1.08414", "", "", "", "", "", "", "", "", "0805", "", "", "", "", "", "", "", "", "88.2", "98.7", "", "", "", "", "96.7"]} +{"pcdb_id": 18244, "brand_name": "Ariston", "model_name": "CLAS SYSTEM ONE 30", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 27.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018244", "000080", "0", "2018/Apr/09 12:16", "Ariston Thermo S.p.A", "Ariston", "CLAS SYSTEM ONE 30", "", "3301048", "2017", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "27.4", "27.4", "", "", "88.8", "79.8", "", "58.3", "", "2", "", "", "102", "1", "2", "39", "4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0805", "", "", "", "", "", "", "", "", "88.2", "98.7", "", "", "", "", "96.7"]} +{"pcdb_id": 18245, "brand_name": "Ariston", "model_name": "E-COMBI ONE 30", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 86.8, "comparative_hot_water_efficiency_pct": 72.7, "output_kw_max": 27.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.007, "loss_factor_f1_kwh_per_day": 1.08414, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018245", "000080", "0", "2020/Jan/22 13:17", "Ariston Thermo S.p.A", "Ariston", "E-COMBI ONE 30", "", "3301132", "2017", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "27.4", "27.4", "", "", "88.8", "86.8", "", "72.7", "", "2", "", "", "104", "1", "2", "39", "4", "0", "", "", "", "0", "", "", "", "", "1", "7.239", "0.14", "0.007", "1.08414", "", "", "", "", "", "", "", "", "0805", "", "", "", "", "", "", "", "", "88.2", "98.7", "", "", "", "", "96.7"]} +{"pcdb_id": 18246, "brand_name": "Ariston", "model_name": "E-SYSTEM ONE 30", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 27.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018246", "000080", "0", "2018/Apr/09 12:18", "Ariston Thermo S.p.A", "Ariston", "E-SYSTEM ONE 30", "", "3301057", "2017", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "27.4", "27.4", "", "", "88.8", "79.8", "", "58.3", "", "2", "", "", "102", "1", "2", "39", "4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0805", "", "", "", "", "", "", "", "", "88.2", "98.7", "", "", "", "", "96.7"]} +{"pcdb_id": 18247, "brand_name": "Ariston", "model_name": "CLAS ONE 38", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 86.6, "comparative_hot_water_efficiency_pct": 68.2, "output_kw_max": 30.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.006, "loss_factor_f1_kwh_per_day": 1.54975, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018247", "000080", "0", "2020/Jan/22 13:17", "Ariston Thermo S.p.A", "Ariston", "CLAS ONE 38", "", "3301045", "2017", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "30.2", "30.2", "", "", "88.8", "86.6", "", "68.2", "", "2", "", "", "104", "1", "2", "35", "4", "0", "", "", "", "0", "", "", "", "", "1", "7.727", "0.144", "0.006", "1.54975", "", "", "", "", "", "", "", "", "0805", "", "", "", "", "", "", "", "", "87.8", "98.8", "", "", "", "", "96.8"]} +{"pcdb_id": 18248, "brand_name": "Ariston", "model_name": "CLAS NET ONE 38", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 86.6, "comparative_hot_water_efficiency_pct": 68.2, "output_kw_max": 30.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.006, "loss_factor_f1_kwh_per_day": 1.54975, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018248", "000080", "0", "2020/Jan/22 13:17", "Ariston Thermo S.p.A", "Ariston", "CLAS NET ONE 38", "", "3301051", "2017", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "30.2", "30.2", "", "", "88.8", "86.6", "", "68.2", "", "2", "", "", "104", "1", "2", "35", "4", "0", "", "", "", "0", "", "", "", "", "1", "7.727", "0.144", "0.006", "1.54975", "", "", "", "", "", "", "", "", "0805", "", "", "", "", "", "", "", "", "87.8", "98.8", "", "", "", "", "96.8"]} +{"pcdb_id": 18249, "brand_name": "Vokera BY RIELLO", "model_name": "evolve", "model_qualifier": "24C", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 86.7, "comparative_hot_water_efficiency_pct": 77.0, "output_kw_max": 17.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.004, "loss_factor_f1_kwh_per_day": 0.71045, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018249", "000011", "0", "2019/Aug/15 08:24", "Vokera", "Vokera BY RIELLO", "evolve", "24C", "20119408", "2017", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "17.6", "17.6", "", "", "88.9", "86.7", "", "77.0", "", "2", "", "", "104", "1", "2", "28", "3", "0", "", "", "0", "0", "", "", "", "", "1", "6.835", "0.109", "0.004", "0.71045", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "88.1", "98.9", "", "", "", "", "96.9"]} +{"pcdb_id": 18250, "brand_name": "Baxi", "model_name": "630 Combi", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 86.7, "comparative_hot_water_efficiency_pct": 79.3, "output_kw_max": 20.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0009, "loss_factor_f1_kwh_per_day": 0.53976, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018250", "000005", "0", "2020/Jan/22 13:17", "Baxi", "Baxi", "630 Combi", "", "GC No 47-077-29", "2017", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "20", "20", "", "", "88.4", "86.7", "", "79.3", "", "2", "", "", "104", "1", "2", "78", "3", "0", "", "", "", "0", "", "", "", "", "1", "6.641", "0.105", "0.0009", "0.53976", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "88.0", "97.8", "", "", "", "", "95.9"]} +{"pcdb_id": 18251, "brand_name": "Baxi", "model_name": "624 Combi", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 86.7, "comparative_hot_water_efficiency_pct": 80.2, "output_kw_max": 20.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0004, "loss_factor_f1_kwh_per_day": 0.46731, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018251", "000005", "0", "2020/Jan/22 13:17", "Baxi", "Baxi", "624 Combi", "", "GC No 47-077-28", "2017", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "20", "20", "", "", "88.4", "86.7", "", "80.2", "", "2", "", "", "104", "1", "2", "68", "3", "0", "", "", "", "0", "", "", "", "", "1", "6.563", "0.102", "0.0004", "0.46731", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "88.0", "97.8", "", "", "", "", "95.9"]} +{"pcdb_id": 18252, "brand_name": "Vokera BY RIELLO", "model_name": "evolve", "model_qualifier": "18S", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 17.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018252", "000011", "0", "2019/Aug/15 08:45", "Vokera", "Vokera BY RIELLO", "evolve", "18S", "20127447", "2017", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "17.6", "17.6", "", "", "88.9", "79.9", "", "58.3", "", "2", "", "", "102", "1", "2", "28", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "88.1", "98.9", "", "", "", "", "96.9"]} +{"pcdb_id": 18253, "brand_name": "Vokera BY RIELLO", "model_name": "evolve", "model_qualifier": "24S", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 23.54, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018253", "000011", "0", "2019/Aug/15 08:59", "Vokera", "Vokera BY RIELLO", "evolve", "24S", "20127448", "2017", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "23.54", "23.54", "", "", "88.9", "79.9", "", "58.4", "", "2", "", "", "102", "1", "2", "37", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "88.4", "98.9", "", "", "", "", "96.9"]} +{"pcdb_id": 18254, "brand_name": "Vokera BY RIELLO", "model_name": "evolve", "model_qualifier": "28C", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 86.8, "comparative_hot_water_efficiency_pct": 77.0, "output_kw_max": 23.54, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0035, "loss_factor_f1_kwh_per_day": 0.72201, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018254", "000011", "0", "2019/Aug/15 09:01", "Vokera", "Vokera BY RIELLO", "evolve", "28C", "20119409", "2017", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "23.54", "23.54", "", "", "88.9", "86.8", "", "77.0", "", "2", "", "", "104", "1", "2", "37", "3", "0", "", "", "", "0", "", "", "", "", "1", "6.837", "0.109", "0.0035", "0.72201", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "88.4", "98.9", "", "", "", "", "96.9"]} +{"pcdb_id": 18255, "brand_name": "Vokera BY RIELLO", "model_name": "evolve", "model_qualifier": "32C", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 86.8, "comparative_hot_water_efficiency_pct": 77.0, "output_kw_max": 29.37, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.003, "loss_factor_f1_kwh_per_day": 0.72142, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018255", "000011", "0", "2019/Aug/15 09:04", "Vokera", "Vokera BY RIELLO", "evolve", "32C", "20131015", "2017", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "29.37", "29.37", "", "", "88.8", "86.8", "", "77.0", "", "2", "", "", "104", "1", "2", "40", "3", "0", "", "", "", "0", "", "", "", "", "1", "6.838", "0.116", "0.003", "0.72142", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "88.2", "98.7", "", "", "", "", "96.7"]} +{"pcdb_id": 18256, "brand_name": "Warmflow", "model_name": "UTILITY COMBI 90 HE ECO", "model_qualifier": "UC90HEE", "winter_efficiency_pct": 87.5, "summer_efficiency_pct": 81.4, "comparative_hot_water_efficiency_pct": 52.4, "output_kw_max": 27.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 1, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018256", "000063", "0", "2024/Jan/31 10:17", "Warmflow Engineering", "Warmflow", "UTILITY COMBI 90 HE ECO", "UC90HEE", "", "2016", "current", "4", "1", "1", "2", "0", "", "", "2", "3", "2", "27", "27", "", "", "87.5", "81.4", "", "52.4", "", "2", "", "", "203", "1", "1", "200", "0", "1", "2", "", "50", "0", "50", "2", "55", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.6", "93.5", "", "", "", "", "93.0"]} +{"pcdb_id": 18257, "brand_name": "Warmflow", "model_name": "UTILITY COMBI 120 HE ECO", "model_qualifier": "UC120HEE", "winter_efficiency_pct": 86.9, "summer_efficiency_pct": 80.9, "comparative_hot_water_efficiency_pct": 52.1, "output_kw_max": 33.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 1, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018257", "000063", "0", "2024/Jan/31 10:17", "Warmflow Engineering", "Warmflow", "UTILITY COMBI 120 HE ECO", "UC120HEE", "", "2016", "current", "4", "1", "1", "2", "0", "", "", "2", "3", "2", "33", "33", "", "", "86.9", "80.9", "", "52.1", "", "2", "", "", "203", "1", "1", "100", "0", "1", "2", "", "50", "0", "50", "2", "55", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "89.5", "92.6", "", "", "", "", "92.0"]} +{"pcdb_id": 18258, "brand_name": "Warmflow", "model_name": "KABIN PAK COMBI 70 HE ECO", "model_qualifier": "KC70HEE", "winter_efficiency_pct": 87.5, "summer_efficiency_pct": 81.5, "comparative_hot_water_efficiency_pct": 52.4, "output_kw_max": 21.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 1, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018258", "000063", "0", "2024/Jan/31 10:17", "Warmflow Engineering", "Warmflow", "KABIN PAK COMBI 70 HE ECO", "KC70HEE", "", "2016", "current", "4", "1", "2", "2", "0", "", "", "2", "3", "2", "21", "21", "", "", "87.5", "81.5", "", "52.4", "", "2", "", "", "203", "1", "1", "200", "0", "1", "2", "", "50", "0", "50", "2", "55", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.3", "93.3", "", "", "", "", "92.9"]} +{"pcdb_id": 18259, "brand_name": "Warmflow", "model_name": "KABIN PAK COMBI 90 HE ECO", "model_qualifier": "KC90HEE", "winter_efficiency_pct": 87.5, "summer_efficiency_pct": 81.4, "comparative_hot_water_efficiency_pct": 52.4, "output_kw_max": 27.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 1, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018259", "000063", "0", "2024/Jan/31 10:17", "Warmflow Engineering", "Warmflow", "KABIN PAK COMBI 90 HE ECO", "KC90HEE", "", "2016", "current", "4", "1", "2", "2", "0", "", "", "2", "3", "2", "27", "27", "", "", "87.5", "81.4", "", "52.4", "", "2", "", "", "203", "1", "1", "200", "0", "1", "2", "", "50", "0", "50", "2", "55", "", "0", "", "", "", "", "", "", "", "", "", "0", "0", "", "0003", "", "", "", "", "", "", "", "", "90.6", "93.5", "", "", "", "", "93.0"]} +{"pcdb_id": 18260, "brand_name": "Warmflow", "model_name": "KABIN PAK COMBI 120 HE ECO", "model_qualifier": "KC120HEE", "winter_efficiency_pct": 86.9, "summer_efficiency_pct": 80.9, "comparative_hot_water_efficiency_pct": 52.1, "output_kw_max": 33.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 1, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018260", "000063", "0", "2024/Jan/31 10:17", "Warmflow Engineering", "Warmflow", "KABIN PAK COMBI 120 HE ECO", "KC120HEE", "", "2016", "current", "4", "1", "2", "2", "0", "", "", "2", "3", "2", "33", "33", "", "", "86.9", "80.9", "", "52.1", "", "2", "", "", "203", "1", "1", "100", "0", "1", "2", "", "50", "0", "50", "2", "55", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "89.5", "92.6", "", "", "", "", "92.0"]} +{"pcdb_id": 18261, "brand_name": "Ferroli", "model_name": "i25", "model_qualifier": "", "winter_efficiency_pct": 87.4, "summer_efficiency_pct": 86.2, "comparative_hot_water_efficiency_pct": 88.1, "output_kw_max": 24.1, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.004, "loss_factor_f1_kwh_per_day": 0.0, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018261", "000097", "0", "2017/Dec/18 14:17", "Ferroli", "Ferroli", "i25", "", "GC No 47-267-64", "2017", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.1", "24.1", "", "", "87.4", "86.2", "", "88.1", "", "2", "", "", "104", "1", "2", "55", "3", "0", "", "", "", "0", "", "", "", "", "1", "5.976", "0.11", "0.004", "0.0", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "86.6", "95.8", "", "", "", "", "94.0"]} +{"pcdb_id": 18262, "brand_name": "Ferroli", "model_name": "i29", "model_qualifier": "", "winter_efficiency_pct": 87.4, "summer_efficiency_pct": 86.3, "comparative_hot_water_efficiency_pct": 88.1, "output_kw_max": 27.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.004, "loss_factor_f1_kwh_per_day": 0.0, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018262", "000097", "0", "2017/Dec/18 14:17", "Ferroli", "Ferroli", "i29", "", "GC No 47-267-65", "2017", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "27", "27", "", "", "87.4", "86.3", "", "88.1", "", "2", "", "", "104", "1", "2", "75", "3", "0", "", "", "", "0", "", "", "", "", "1", "5.976", "0.11", "0.004", "0.0", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "86.8", "95.8", "", "", "", "", "94.1"]} +{"pcdb_id": 18263, "brand_name": "EUROTERM", "model_name": "E25", "model_qualifier": "", "winter_efficiency_pct": 87.4, "summer_efficiency_pct": 86.2, "comparative_hot_water_efficiency_pct": 88.1, "output_kw_max": 24.1, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.004, "loss_factor_f1_kwh_per_day": 0.0, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018263", "000097", "0", "2017/Dec/18 14:17", "Ferroli", "EUROTERM", "E25", "", "GC No 47-267-69", "2017", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.1", "24.1", "", "", "87.4", "86.2", "", "88.1", "", "2", "", "", "104", "1", "2", "55", "3", "0", "", "", "", "0", "", "", "", "", "1", "5.976", "0.11", "0.004", "0.0", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "86.6", "95.8", "", "", "", "", "94.0"]} +{"pcdb_id": 18264, "brand_name": "EUROTERM", "model_name": "E29", "model_qualifier": "", "winter_efficiency_pct": 87.4, "summer_efficiency_pct": 86.3, "comparative_hot_water_efficiency_pct": 88.1, "output_kw_max": 27.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.004, "loss_factor_f1_kwh_per_day": 0.0, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018264", "000097", "0", "2017/Dec/18 14:18", "Ferroli", "EUROTERM", "E29", "", "GC No 47-267-70", "2017", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "27", "27", "", "", "87.4", "86.3", "", "88.1", "", "2", "", "", "104", "1", "2", "82", "3", "0", "", "", "", "0", "", "", "", "", "1", "5.976", "0.011", "0.004", "0.0", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "86.8", "95.8", "", "", "", "", "94.1"]} +{"pcdb_id": 18265, "brand_name": "Sime", "model_name": "MURELLE PRO HE 35 MkII", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 86.8, "comparative_hot_water_efficiency_pct": 68.4, "output_kw_max": 30.0, "final_year_of_manufacture": 2019, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.005, "loss_factor_f1_kwh_per_day": 1.54919, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018265", "000213", "0", "2019/Feb/28 13:17", "Fonderie Sime S.p.A.", "Sime", "MURELLE PRO HE 35 MkII", "", "8114248", "2017", "2019", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "30", "30", "", "", "88.4", "86.8", "", "68.4", "", "2", "", "", "104", "1", "2", "47", "3", "0", "", "", "", "0", "", "", "", "", "1", "7.702", "0.237", "0.005", "1.54919", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.5", "97.7", "", "", "", "", "95.9"]} +{"pcdb_id": 18266, "brand_name": "Vaillant", "model_name": "ecoTEC sustain 24", "model_qualifier": "VUW 246/7-2 (H-GB)", "winter_efficiency_pct": 89.9, "summer_efficiency_pct": 81.3, "comparative_hot_water_efficiency_pct": 57.1, "output_kw_max": 18.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018266", "000031", "0", "2017/Dec/13 09:05", "Vaillant", "Vaillant", "ecoTEC sustain 24", "VUW 246/7-2 (H-GB)", "47-044-79", "2017", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "18.5", "18.5", "", "", "89.9", "81.3", "", "57.1", "", "2", "0", "", "104", "1", "2", "19", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.2", "98.8", "", "", "", "", "97.0"]} +{"pcdb_id": 18267, "brand_name": "Vaillant", "model_name": "ecoTEC sustain 28", "model_qualifier": "VUW 286/7-2 (H-GB)", "winter_efficiency_pct": 89.8, "summer_efficiency_pct": 81.2, "comparative_hot_water_efficiency_pct": 57.1, "output_kw_max": 18.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018267", "000031", "0", "2017/Dec/13 09:05", "Vaillant", "Vaillant", "ecoTEC sustain 28", "VUW 286/7-2 (H-GB)", "47-044-80", "2017", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "18.5", "18.5", "", "", "89.8", "81.2", "", "57.1", "", "2", "0", "", "104", "1", "2", "23", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.3", "98.6", "", "", "", "", "96.9"]} +{"pcdb_id": 18268, "brand_name": "Vaillant", "model_name": "ecoTEC sustain 34", "model_qualifier": "VUW 346/7-2 (H-GB)", "winter_efficiency_pct": 89.8, "summer_efficiency_pct": 81.2, "comparative_hot_water_efficiency_pct": 57.1, "output_kw_max": 18.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018268", "000031", "0", "2017/Dec/13 09:06", "Vaillant", "Vaillant", "ecoTEC sustain 34", "VUW 346/7-2 (H-GB)", "47-044-81", "2017", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "18.5", "18.5", "", "", "89.8", "81.2", "", "57.1", "", "2", "0", "", "104", "1", "2", "13", "3", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.6", "98.5", "", "", "", "", "96.8"]} +{"pcdb_id": 18269, "brand_name": "Alpha", "model_name": "InTec 40 GS2", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 98.9, "comparative_hot_water_efficiency_pct": 81.0, "output_kw_max": 28.0, "final_year_of_manufacture": null, "subsidiary_type": 1, "store_type": 0, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.0035, "loss_factor_f1_kwh_per_day": 0.42069, "loss_factor_f2_kwh_per_day": 1.1267, "rejected_factor_f3_per_litre": 2e-05, "raw": ["018269", "000001", "3", "2021/Nov/29 20:19", "Alpha Therm", "Alpha", "InTec 40 GS2", "", "3.028276", "2017", "current", "1", "2", "1", "2", "1", "313", "060041", "2", "2", "2", "28.0", "28.0", "", "", "88.3", "98.9", "", "81.0", "", "2", "", "", "104", "1", "2", "37", "6", "0", "", "", "", "0", "", "", "", "", "2", "6.5", "0.208", "0.0035", "0.42069", "11.79", "0.23", "0.0015", "1.1267", "0.00002", "", "", "", "1005", "", "", "", "", "", "", "", "", "89.4", "97.0", "", "", "", "", "95.6"]} +{"pcdb_id": 18270, "brand_name": "Potterton", "model_name": "Titanium", "model_qualifier": "12 Heat", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 13.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018270", "000005", "0", "2017/Dec/13 17:10", "Baxi Heating UK", "Potterton", "Titanium", "12 Heat", "41-592-61", "2017", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "13.0", "13.0", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "17", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.3", "98.0", "", "", "", "", "96.0"]} +{"pcdb_id": 18271, "brand_name": "Potterton", "model_name": "Titanium", "model_qualifier": "15 Heat", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 16.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018271", "000005", "0", "2017/Dec/13 17:10", "Baxi Heating UK", "Potterton", "Titanium", "15 Heat", "41-592-62", "2017", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "16.0", "16.0", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "20", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.3", "98.0", "", "", "", "", "96.0"]} +{"pcdb_id": 18272, "brand_name": "Potterton", "model_name": "Titanium", "model_qualifier": "18 Heat", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 19.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018272", "000005", "0", "2017/Dec/13 17:12", "Baxi Heating UK", "Potterton", "Titanium", "18 Heat", "41-592-63", "2017", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "19.0", "19.0", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "23", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.3", "98.0", "", "", "", "", "96.0"]} +{"pcdb_id": 18273, "brand_name": "Potterton", "model_name": "Titanium", "model_qualifier": "24 Heat", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 25.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018273", "000005", "0", "2017/Dec/13 17:14", "Baxi Heating UK", "Potterton", "Titanium", "24 Heat", "41-592-64", "2017", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "25.0", "25.0", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "33", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.3", "98.0", "", "", "", "", "96.0"]} +{"pcdb_id": 18274, "brand_name": "Potterton", "model_name": "Titanium", "model_qualifier": "30 Heat", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 30.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018274", "000005", "0", "2017/Dec/13 17:14", "Baxi Heating UK", "Potterton", "Titanium", "30 Heat", "41-592-65", "2017", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "30.0", "30.0", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "44", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.3", "98.0", "", "", "", "", "96.0"]} +{"pcdb_id": 18275, "brand_name": "Ideal", "model_name": "Exclusive", "model_qualifier": "24", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 71.7, "output_kw_max": 24.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0022, "loss_factor_f1_kwh_per_day": 1.2604, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018275", "000008", "0", "2017/Nov/15 13:17", "Ideal Boilers", "Ideal", "Exclusive", "24", "47-349-41", "2017", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "88.3", "87.3", "", "71.7", "", "2", "", "", "104", "1", "2", "42", "5", "0", "", "", "", "0", "", "", "", "", "1", "7.348", "0.11", "0.0022", "1.2604", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "", "", "", "", "89.8", "96.9", "", "", "", "", "95.5"]} +{"pcdb_id": 18276, "brand_name": "Ideal", "model_name": "Exclusive", "model_qualifier": "30", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 71.4, "output_kw_max": 24.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0023, "loss_factor_f1_kwh_per_day": 1.28692, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018276", "000008", "0", "2017/Nov/15 13:17", "Ideal Boilers", "Ideal", "Exclusive", "30", "47-349-42", "2017", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "88.4", "87.3", "", "71.4", "", "2", "", "", "104", "1", "2", "32", "5", "0", "", "", "", "0", "", "", "", "", "1", "7.371", "0.109", "0.0023", "1.28692", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "", "", "", "", "90.0", "96.9", "", "", "", "", "95.6"]} +{"pcdb_id": 18277, "brand_name": "Ideal", "model_name": "Exclusive", "model_qualifier": "35", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 72.1, "output_kw_max": 24.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0023, "loss_factor_f1_kwh_per_day": 1.2201, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018277", "000008", "0", "2017/Nov/15 13:18", "Ideal Boilers", "Ideal", "Exclusive", "35", "47-349-43", "2017", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "88.3", "87.3", "", "72.1", "", "2", "", "", "104", "1", "2", "29", "5", "0", "", "", "", "0", "", "", "", "", "1", "7.307", "0.108", "0.0023", "1.2201", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "", "", "", "", "89.8", "96.9", "", "", "", "", "95.5"]} +{"pcdb_id": 18278, "brand_name": "Baxi", "model_name": "EcoBlue Advance", "model_qualifier": "21 Heat ErP", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 21.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018278", "000005", "0", "2018/Jan/11 14:04", "Baxi Heating UK", "Baxi", "EcoBlue Advance", "21 Heat ErP", "41-470-55", "2017", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "21.0", "21.0", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "25", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.3", "98.0", "", "", "", "", "96.0"]} +{"pcdb_id": 18280, "brand_name": "Firebird", "model_name": "Enviromax Combi HE", "model_qualifier": "20kW", "winter_efficiency_pct": 89.3, "summer_efficiency_pct": 83.4, "comparative_hot_water_efficiency_pct": 45.3, "output_kw_max": 20.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 1, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018280", "000047", "0", "2024/Jan/31 10:17", "Firebird Heating Solutions Ltd", "Firebird", "Enviromax Combi HE", "20kW", "", "2017", "current", "4", "1", "1", "2", "0", "", "", "2", "2", "1", "20", "20", "", "", "89.3", "83.4", "", "45.3", "", "2", "", "", "203", "1", "1", "", "", "1", "2", "0", "44.02", "0", "25", "1", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "92.8", "97.4", "", "", "", "", "96.5"]} +{"pcdb_id": 18281, "brand_name": "Firebird", "model_name": "Enviromax Combi HE", "model_qualifier": "26kW", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 83.2, "comparative_hot_water_efficiency_pct": 45.2, "output_kw_max": 26.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 1, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018281", "000047", "0", "2024/Jan/31 10:17", "Firebird Heating Solutions Ltd", "Firebird", "Enviromax Combi HE", "26kW", "", "2017", "current", "4", "1", "1", "2", "0", "", "", "2", "2", "1", "26.0", "26.0", "", "", "89.1", "83.2", "", "45.2", "", "2", "", "", "203", "1", "1", "", "", "1", "2", "0", "44.02", "0", "25", "1", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "92.7", "96.9", "", "", "", "", "96.1"]} +{"pcdb_id": 18282, "brand_name": "Firebird", "model_name": "Enviromax Combi HE", "model_qualifier": "35kW", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 82.7, "comparative_hot_water_efficiency_pct": 45.0, "output_kw_max": 35.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 1, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018282", "000047", "0", "2024/Jan/31 10:17", "Firebird Heating Solutions Ltd", "Firebird", "Enviromax Combi HE", "35kW", "", "2017", "current", "4", "1", "1", "2", "0", "", "", "2", "2", "1", "35.0", "35.0", "", "", "88.7", "82.7", "", "45.0", "", "2", "", "", "203", "1", "1", "", "", "1", "2", "0", "44.02", "0", "25", "1", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "92.5", "95.9", "", "", "", "", "95.2"]} +{"pcdb_id": 18283, "brand_name": "Biasi", "model_name": "ADVANCE 25C", "model_qualifier": "", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 55.8, "output_kw_max": 20.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018283", "000208", "0", "2018/Jan/15 11:13", "Biasi", "Biasi", "ADVANCE 25C", "", "47-583-43", "2017", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "20.3", "20.3", "", "", "87.9", "79.3", "", "55.8", "", "2", "", "", "104", "1", "2", "36", "3", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.0", "96.9", "", "", "", "", "95.1"]} +{"pcdb_id": 18284, "brand_name": "Biasi", "model_name": "ADVANCE 30C", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 55.8, "output_kw_max": 24.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018284", "000208", "0", "2018/Jan/15 11:14", "Biasi", "Biasi", "ADVANCE 30C", "", "47-583-44", "2017", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.4", "24.4", "", "", "88.0", "79.4", "", "55.8", "", "2", "", "", "104", "1", "2", "40", "3", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "96.8", "", "", "", "", "95.1"]} +{"pcdb_id": 18285, "brand_name": "Biasi", "model_name": "ADVANCE 35C", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 55.8, "output_kw_max": 28.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018285", "000208", "0", "2018/Jan/15 11:14", "Biasi", "Biasi", "ADVANCE 35C", "", "47-583-45", "2017", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28.2", "28.2", "", "", "88.0", "79.4", "", "55.8", "", "2", "", "", "104", "1", "2", "53", "3", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "96.8", "", "", "", "", "95.1"]} +{"pcdb_id": 18286, "brand_name": "Biasi", "model_name": "ADVANCE 25S", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 24.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018286", "000208", "0", "2018/Jan/15 11:15", "Biasi", "Biasi", "ADVANCE 25S", "", "41-583-33", "2017", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24.4", "24.4", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "40", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "96.8", "", "", "", "", "95.1"]} +{"pcdb_id": 18287, "brand_name": "Biasi", "model_name": "ADVANCE 30S", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 28.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018287", "000208", "0", "2018/Jan/15 11:15", "Biasi", "Biasi", "ADVANCE 30S", "", "41-583-34", "2017", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "28.2", "28.2", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "53", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "96.8", "", "", "", "", "95.1"]} +{"pcdb_id": 18288, "brand_name": "Keston", "model_name": "COMBI C35P", "model_qualifier": "", "winter_efficiency_pct": 90.1, "summer_efficiency_pct": 81.5, "comparative_hot_water_efficiency_pct": 57.3, "output_kw_max": 24.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018288", "000022", "0", "2018/Jan/15 10:42", "Keston Boilers", "Keston", "COMBI C35P", "", "", "2017", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "90.1", "81.5", "", "57.3", "", "2", "1", "", "104", "1", "2", "29", "5", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "92.0", "100.8", "", "", "", "", "99.1"]} +{"pcdb_id": 18289, "brand_name": "De Dietrich", "model_name": "MPX", "model_qualifier": "24 COMPACT", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 24.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018289", "000305", "0", "2018/Jan/17 15:42", "De Dietrich Thermique", "De Dietrich", "MPX", "24 COMPACT", "", "2018", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24.0", "24.0", "", "", "88.5", "79.5", "", "58.1", "", "2", "", "", "102", "1", "2", "42", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "98.0", "", "", "", "", "96.1"]} +{"pcdb_id": 18290, "brand_name": "De Dietrich", "model_name": "MPX", "model_qualifier": "24 COMPACT", "winter_efficiency_pct": 89.5, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 58.8, "output_kw_max": 24.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018290", "000305", "0", "2018/Jan/17 15:42", "De Dietrich Thermique", "De Dietrich", "MPX", "24 COMPACT", "", "2018", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "24.0", "24.0", "", "", "89.5", "80.5", "", "58.8", "", "2", "1", "", "102", "1", "2", "42", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.9", "100.2", "", "", "", "", "98.2"]} +{"pcdb_id": 18291, "brand_name": "De Dietrich", "model_name": "MPX", "model_qualifier": "20/24 MI COMPACT", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 56.2, "output_kw_max": 24.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018291", "000305", "0", "2018/Jan/17 15:42", "De Dietrich Thermique", "De Dietrich", "MPX", "20/24 MI COMPACT", "", "2018", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.0", "24.0", "", "", "88.5", "79.9", "", "56.2", "", "2", "", "", "104", "1", "2", "30", "3", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "98.0", "", "", "", "", "96.1"]} +{"pcdb_id": 18292, "brand_name": "De Dietrich", "model_name": "MPX", "model_qualifier": "20/24 MI COMPACT", "winter_efficiency_pct": 89.5, "summer_efficiency_pct": 80.9, "comparative_hot_water_efficiency_pct": 56.9, "output_kw_max": 24.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018292", "000305", "0", "2018/Jan/17 15:42", "De Dietrich Thermique", "De Dietrich", "MPX", "20/24 MI COMPACT", "", "2018", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24.0", "24.0", "", "", "89.5", "80.9", "", "56.9", "", "2", "1", "", "104", "1", "2", "30", "3", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.0", "100.2", "", "", "", "", "98.3"]} +{"pcdb_id": 18293, "brand_name": "De Dietrich", "model_name": "MPX", "model_qualifier": "24/28 MI COMPACT", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 56.2, "output_kw_max": 28.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018293", "000305", "0", "2018/Jan/17 15:43", "De Dietrich Thermique", "De Dietrich", "MPX", "24/28 MI COMPACT", "", "2018", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28.0", "28.0", "", "", "88.5", "79.9", "", "56.2", "", "2", "", "", "104", "1", "2", "42", "3", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "98.0", "", "", "", "", "96.1"]} +{"pcdb_id": 18295, "brand_name": "De Dietrich", "model_name": "MPX", "model_qualifier": "24/28 MI COMPACT", "winter_efficiency_pct": 89.5, "summer_efficiency_pct": 80.9, "comparative_hot_water_efficiency_pct": 56.9, "output_kw_max": 28.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018295", "000305", "0", "2018/Jan/17 17:00", "De Dietrich Thermique", "De Dietrich", "MPX", "24/28 MI COMPACT", "", "2018", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "28.0", "28.0", "", "", "89.5", "80.9", "", "56.9", "", "2", "1", "", "104", "1", "2", "42", "3", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.9", "100.2", "", "", "", "", "98.2"]} +{"pcdb_id": 18296, "brand_name": "De Dietrich", "model_name": "MPX", "model_qualifier": "28/33 MI COMPACT", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 56.2, "output_kw_max": 33.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018296", "000305", "0", "2018/Jan/17 15:43", "De Dietrich Thermique", "De Dietrich", "MPX", "28/33 MI COMPACT", "", "2018", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "33.0", "33.0", "", "", "88.5", "79.9", "", "56.2", "", "2", "", "", "104", "1", "2", "41", "3", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.1", "98.1", "", "", "", "", "96.2"]} +{"pcdb_id": 18297, "brand_name": "De Dietrich", "model_name": "MPX", "model_qualifier": "28/33 MI COMPACT", "winter_efficiency_pct": 89.6, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 56.9, "output_kw_max": 33.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018297", "000305", "0", "2018/Jan/17 17:04", "De Dietrich Thermique", "De Dietrich", "MPX", "28/33 MI COMPACT", "", "2018", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "33.0", "33.0", "", "", "89.6", "81.0", "", "56.9", "", "2", "1", "", "104", "1", "2", "41", "3", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.1", "100.3", "", "", "", "", "98.4"]} +{"pcdb_id": 18298, "brand_name": "De Dietrich", "model_name": "MPX", "model_qualifier": "28/33 BIC", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 56.2, "output_kw_max": 33.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018298", "000305", "0", "2018/Jan/17 15:43", "De Dietrich Thermique", "De Dietrich", "MPX", "28/33 BIC", "", "2018", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "33.0", "33.0", "", "", "88.5", "79.9", "", "56.2", "", "2", "", "", "104", "1", "2", "41", "3", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.1", "98.1", "", "", "", "", "96.2"]} +{"pcdb_id": 18299, "brand_name": "De Dietrich", "model_name": "MPX", "model_qualifier": "28/33 BIC", "winter_efficiency_pct": 89.6, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 56.9, "output_kw_max": 33.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018299", "000305", "0", "2018/Jan/17 15:43", "De Dietrich Thermique", "De Dietrich", "MPX", "28/33 BIC", "", "2018", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "33.0", "33.0", "", "", "89.6", "81.0", "", "56.9", "", "2", "1", "", "104", "1", "2", "41", "3", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.1", "100.3", "", "", "", "", "98.4"]} +{"pcdb_id": 18300, "brand_name": "Warmhaus", "model_name": "Enerwa", "model_qualifier": "Plus 2530 C", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 56.1, "output_kw_max": 23.7, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018300", "000306", "0", "2018/Apr/09 14:42", "Warmhaus Heating Ltd", "Warmhaus", "Enerwa", "Plus 2530 C", "CE-1015CR0544 16", "2016", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "23.7", "23.7", "", "", "88.4", "79.8", "", "56.1", "", "2", "", "", "104", "1", "2", "70", "5", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "97.6", "", "", "", "", "95.8"]} +{"pcdb_id": 18301, "brand_name": "Warmhaus", "model_name": "Enerwa", "model_qualifier": "Plus 3035 C", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 55.9, "output_kw_max": 28.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018301", "000306", "0", "2018/Apr/09 14:42", "Warmhaus Heating Ltd", "Warmhaus", "Enerwa", "Plus 3035 C", "CE-1015CR0553 17", "2016", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28.0", "28.0", "", "", "88.1", "79.5", "", "55.9", "", "2", "", "", "104", "1", "2", "70", "5", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.2", "96.9", "", "", "", "", "95.2"]} +{"pcdb_id": 18302, "brand_name": "Warmhaus", "model_name": "Enerwa", "model_qualifier": "3540 C", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 55.8, "output_kw_max": 33.02, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018302", "000306", "0", "2018/Apr/09 14:42", "Warmhaus Heating Ltd", "Warmhaus", "Enerwa", "3540 C", "CE-1015CS0565 17", "2016", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "33.02", "33.02", "", "", "88.0", "79.4", "", "55.8", "", "2", "", "", "104", "1", "2", "70", "5", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.3", "96.6", "", "", "", "", "95.0"]} +{"pcdb_id": 18319, "brand_name": "Vokera BY RIELLO", "model_name": "evolve", "model_qualifier": "36c", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 86.8, "comparative_hot_water_efficiency_pct": 77.2, "output_kw_max": 31.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0005, "loss_factor_f1_kwh_per_day": 0.72894, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018319", "000011", "0", "2020/Jan/22 13:18", "Vokera", "Vokera BY RIELLO", "evolve", "36c", "20131016", "2017", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "31", "31", "", "", "88.8", "86.8", "", "77.2", "", "2", "", "", "104", "1", "2", "31", "3", "0", "", "", "", "0", "", "", "", "", "1", "6.826", "0.116", "0.0005", "0.72894", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "88.4", "98.7", "", "", "", "", "96.7"]} +{"pcdb_id": 18320, "brand_name": "Vokera BY RIELLO", "model_name": "evolve", "model_qualifier": "30s", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 31.39, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018320", "000011", "0", "2019/Aug/15 09:23", "Vokera", "Vokera BY RIELLO", "evolve", "30s", "20131081", "2017", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "31.39", "31.39", "", "", "88.8", "79.8", "", "58.3", "", "2", "", "", "102", "1", "2", "31", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "88.4", "98.7", "", "", "", "", "96.7"]} +{"pcdb_id": 18322, "brand_name": "ATAG", "model_name": "IC Economiser Plus 35", "model_qualifier": "", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 97.8, "comparative_hot_water_efficiency_pct": 79.9, "output_kw_max": 28.3, "final_year_of_manufacture": null, "subsidiary_type": 1, "store_type": 0, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.0013, "loss_factor_f1_kwh_per_day": 0.50098, "loss_factor_f2_kwh_per_day": 1.1609, "rejected_factor_f3_per_litre": 1e-05, "raw": ["018322", "000299", "3", "2021/Nov/29 20:19", "ATAG Verwarming Nederland BV", "ATAG", "IC Economiser Plus 35", "", "", "2018", "current", "1", "2", "1", "2", "1", "313", "060043", "2", "3", "2", "28.3", "28.3", "", "", "89.1", "97.8", "", "79.9", "", "2", "", "", "104", "1", "2", "74", "4", "0", "", "", "", "0", "", "", "", "", "2", "6.59", "0.168", "0.0013", "0.50098", "11.94", "0.183", "0.0007", "1.1609", "0.00001", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.6", "99.5", "", "", "", "", "97.4"]} +{"pcdb_id": 18323, "brand_name": "ATAG", "model_name": "IC Economiser Plus 39", "model_qualifier": "", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 97.8, "comparative_hot_water_efficiency_pct": 79.9, "output_kw_max": 28.3, "final_year_of_manufacture": null, "subsidiary_type": 1, "store_type": 0, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.0013, "loss_factor_f1_kwh_per_day": 0.50098, "loss_factor_f2_kwh_per_day": 1.1609, "rejected_factor_f3_per_litre": 1e-05, "raw": ["018323", "000299", "3", "2021/Nov/29 20:19", "ATAG Verwarming Nederland BV", "ATAG", "IC Economiser Plus 39", "", "", "2018", "current", "1", "2", "1", "2", "1", "313", "060043", "2", "3", "2", "28.3", "28.3", "", "", "89.1", "97.8", "", "79.9", "", "2", "", "", "104", "1", "2", "74", "4", "0", "", "", "", "0", "", "", "", "", "2", "6.59", "0.168", "0.0013", "0.50098", "11.94", "0.183", "0.0007", "1.1609", "0.00001", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.6", "99.5", "", "", "", "", "97.4"]} +{"pcdb_id": 18324, "brand_name": "Vokera BY RIELLO", "model_name": "evolve", "model_qualifier": "42C", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 86.8, "comparative_hot_water_efficiency_pct": 77.0, "output_kw_max": 34.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.002, "loss_factor_f1_kwh_per_day": 0.73046, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018324", "000011", "0", "2020/Jan/22 12:59", "Vokera", "Vokera BY RIELLO", "evolve", "42C", "20131017", "2017", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "34.3", "34.3", "", "", "88.7", "86.8", "", "77.0", "", "2", "", "", "104", "1", "2", "34", "3", "0", "", "", "", "0", "", "", "", "", "1", "6.839", "0.121", "0.002", "0.73046", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "", "", "", "", "88.3", "98.6", "", "", "", "", "96.6"]} +{"pcdb_id": 18325, "brand_name": "Trianco", "model_name": "TRO EVOLUTION 20 KITCHEN SYSTEM", "model_qualifier": "", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 81.4, "comparative_hot_water_efficiency_pct": 59.4, "output_kw_max": 20.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018325", "000062", "0", "2020/Jan/22 12:59", "TR Engineering Ltd", "Trianco", "TRO EVOLUTION 20 KITCHEN SYSTEM", "", "", "2018", "current", "4", "1", "1", "1", "0", "", "", "2", "2", "2", "20", "20", "", "", "89.2", "81.4", "", "59.4", "", "2", "", "", "201", "1", "1", "217", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.7", "97.4", "", "", "", "", "96.3"]} +{"pcdb_id": 18326, "brand_name": "Trianco", "model_name": "TRO EVOLUTION 30 KITCHEN SYSTEM", "model_qualifier": "", "winter_efficiency_pct": 89.3, "summer_efficiency_pct": 81.5, "comparative_hot_water_efficiency_pct": 59.5, "output_kw_max": 30.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018326", "000062", "0", "2018/Mar/26 09:30", "TR Engineering Ltd", "Trianco", "TRO EVOLUTION 30 KITCHEN SYSTEM", "", "", "2018", "current", "4", "1", "1", "1", "0", "", "", "2", "2", "2", "30", "30", "", "", "89.3", "81.5", "", "59.5", "", "2", "", "", "201", "1", "1", "217", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.5", "97.8", "", "", "", "", "96.6"]} +{"pcdb_id": 18327, "brand_name": "Vokera BY RIELLO", "model_name": "evolve", "model_qualifier": "35s", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 34.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018327", "000011", "0", "2019/Nov/22 09:56", "Vokera", "Vokera BY RIELLO", "evolve", "35s", "20131082", "2017", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "34.3", "34.3", "", "", "88.7", "79.7", "", "58.3", "", "2", "", "", "102", "1", "2", "34", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "", "", "", "", "88.3", "98.6", "", "", "", "", "96.6"]} +{"pcdb_id": 18329, "brand_name": "Ideal", "model_name": "LOGIC COMBI", "model_qualifier": "C24IE", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 69.8, "output_kw_max": 24.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0025, "loss_factor_f1_kwh_per_day": 1.4583, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018329", "000008", "0", "2020/Jan/22 13:00", "Ideal Boilers", "Ideal", "LOGIC COMBI", "C24IE", "47-349-44", "2018", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "89.0", "87.3", "", "69.8", "", "2", "", "", "104", "1", "2", "70", "5", "0", "", "", "", "0", "", "", "", "", "1", "7.549", "0.076", "0.0025", "1.4583", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.0", "98.6", "", "", "", "", "96.9"]} +{"pcdb_id": 18330, "brand_name": "Ideal", "model_name": "LOGIC COMBI", "model_qualifier": "C30IE", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 70.4, "output_kw_max": 24.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0025, "loss_factor_f1_kwh_per_day": 1.38753, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018330", "000008", "0", "2020/Jan/22 13:00", "Ideal Boilers", "Ideal", "LOGIC COMBI", "C30IE", "47-349-45", "2018", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "89.0", "87.3", "", "70.4", "", "2", "", "", "104", "1", "2", "70", "5", "0", "", "", "", "0", "", "", "", "", "1", "7.476", "0.74", "0.0025", "1.38753", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.0", "98.6", "", "", "", "", "96.9"]} +{"pcdb_id": 18331, "brand_name": "Ideal", "model_name": "LOGIC COMBI", "model_qualifier": "C35IE", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 71.1, "output_kw_max": 24.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0025, "loss_factor_f1_kwh_per_day": 1.3247, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018331", "000008", "0", "2020/Jan/22 13:00", "Ideal Boilers", "Ideal", "LOGIC COMBI", "C35IE", "47-349-46", "2018", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "89.0", "87.3", "", "71.1", "", "2", "", "", "104", "1", "2", "70", "5", "0", "", "", "", "0", "", "", "", "", "1", "7.411", "0.074", "0.0025", "1.3247", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.0", "98.6", "", "", "", "", "96.9"]} +{"pcdb_id": 18335, "brand_name": "Vaillant", "model_name": "ecoTEC plus", "model_qualifier": "VU 446/5-5 (H-GB)", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 45.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018335", "000031", "0", "2020/Jan/22 13:00", "Vaillant", "Vaillant", "ecoTEC plus", "VU 446/5-5 (H-GB)", "41-649-28", "2018", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "45.2", "45.2", "", "", "88.6", "79.6", "", "58.1", "", "2", "", "", "102", "1", "2", "24", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0045", "", "", "", "", "", "", "", "", "87.8", "98.3", "", "", "", "", "96.3"]} +{"pcdb_id": 18336, "brand_name": "Vaillant", "model_name": "ecoTEC plus", "model_qualifier": "VU 446/5-5 (H-GB)", "winter_efficiency_pct": 89.3, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 58.7, "output_kw_max": 45.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018336", "000031", "0", "2019/Jul/31 11:50", "Vaillant", "Vaillant", "ecoTEC plus", "VU 446/5-5 (H-GB)", "41-649-28", "2018", "current", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "45.2", "45.2", "", "", "89.3", "80.3", "", "58.7", "", "2", "0", "", "102", "1", "2", "24", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0045", "", "", "", "", "", "", "", "", "89.7", "97.3", "", "", "", "", "95.8"]} +{"pcdb_id": 18337, "brand_name": "Vaillant", "model_name": "ecoTEC plus", "model_qualifier": "VU 606/5-5 (H-GB)", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 60.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018337", "000031", "0", "2019/Jul/31 11:51", "Vaillant", "Vaillant", "ecoTEC plus", "VU 606/5-5 (H-GB)", "41-649-29", "2018", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "60", "60", "", "", "88.8", "79.8", "", "58.3", "", "2", "", "", "102", "1", "2", "31", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0045", "", "", "", "", "", "", "", "", "88.1", "98.7", "", "", "", "", "96.7"]} +{"pcdb_id": 18338, "brand_name": "Vaillant", "model_name": "ecoTEC plus", "model_qualifier": "VU 606/5-5 (H-GB)", "winter_efficiency_pct": 89.7, "summer_efficiency_pct": 80.7, "comparative_hot_water_efficiency_pct": 59.0, "output_kw_max": 60.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018338", "000031", "0", "2019/Jul/31 11:51", "Vaillant", "Vaillant", "ecoTEC plus", "VU 606/5-5 (H-GB)", "41-649-29", "2018", "current", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "60", "60", "", "", "89.7", "80.7", "", "59.0", "", "2", "0", "", "102", "1", "2", "31", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0045", "", "", "", "", "", "", "", "", "89.7", "98.3", "", "", "", "", "96.6"]} +{"pcdb_id": 18339, "brand_name": "Ideal", "model_name": "LOGIC COMBI C IE", "model_qualifier": "C24P IE", "winter_efficiency_pct": 90.1, "summer_efficiency_pct": 81.5, "comparative_hot_water_efficiency_pct": 57.3, "output_kw_max": 24.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018339", "000008", "0", "2018/May/16 14:16", "Ideal Boilers", "Ideal", "LOGIC COMBI C IE", "C24P IE", "", "2018", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "90.1", "81.5", "", "57.3", "", "2", "1", "", "104", "1", "2", "42", "5", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "92.0", "100.8", "", "", "", "", "99.1"]} +{"pcdb_id": 18340, "brand_name": "Ideal", "model_name": "LOGIC COMBI C IE", "model_qualifier": "C30P IE", "winter_efficiency_pct": 90.1, "summer_efficiency_pct": 81.5, "comparative_hot_water_efficiency_pct": 57.3, "output_kw_max": 24.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018340", "000008", "0", "2018/May/16 14:16", "Ideal Boilers", "Ideal", "LOGIC COMBI C IE", "C30P IE", "", "2018", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "90.1", "81.5", "", "57.3", "", "2", "1", "", "104", "1", "2", "31", "5", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "92.0", "100.8", "", "", "", "", "99.1"]} +{"pcdb_id": 18341, "brand_name": "Ideal", "model_name": "LOGIC HEAT", "model_qualifier": "H12IE", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 12.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018341", "000008", "0", "2018/Apr/19 12:49", "Ideal Boilers", "Ideal", "LOGIC HEAT", "H12IE", "41-750-92", "2018", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "12", "12", "", "", "88.8", "79.8", "", "58.3", "", "2", "", "", "102", "1", "2", "20", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.0", "97.9", "", "", "", "", "96.4"]} +{"pcdb_id": 18342, "brand_name": "Ideal", "model_name": "LOGIC HEAT", "model_qualifier": "H15IE", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 15.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018342", "000008", "0", "2018/Apr/19 12:50", "Ideal Boilers", "Ideal", "LOGIC HEAT", "H15IE", "41-750-93", "2018", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "15.0", "15.0", "", "", "88.7", "79.7", "", "58.2", "", "2", "", "", "102", "1", "2", "21", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.0", "97.8", "", "", "", "", "96.4"]} +{"pcdb_id": 18343, "brand_name": "Ideal", "model_name": "LOGIC HEAT", "model_qualifier": "H18IE", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 18.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018343", "000008", "0", "2018/Apr/19 12:51", "Ideal Boilers", "Ideal", "LOGIC HEAT", "H18IE", "41-750-94", "2018", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18.0", "18.0", "", "", "89.0", "80.0", "", "58.4", "", "2", "", "", "102", "1", "2", "26", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.8", "98.5", "", "", "", "", "96.8"]} +{"pcdb_id": 18344, "brand_name": "Ideal", "model_name": "LOGIC HEAT", "model_qualifier": "H24IE", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 24.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018344", "000008", "0", "2018/Apr/19 12:51", "Ideal Boilers", "Ideal", "LOGIC HEAT", "H24IE", "41-750-95", "2018", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "89.0", "80.0", "", "58.5", "", "2", "", "", "102", "1", "2", "42", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.0", "98.6", "", "", "", "", "96.9"]} +{"pcdb_id": 18345, "brand_name": "Ideal", "model_name": "LOGIC HEAT", "model_qualifier": "H30IE", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 30.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018345", "000008", "0", "2018/Apr/19 12:52", "Ideal Boilers", "Ideal", "LOGIC HEAT", "H30IE", "41-750-96", "2018", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "30.3", "30.3", "", "", "88.8", "79.8", "", "58.3", "", "2", "", "", "102", "1", "2", "48", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.6", "98.2", "", "", "", "", "96.6"]} +{"pcdb_id": 18346, "brand_name": "Ideal", "model_name": "LOGIC HEAT HIE", "model_qualifier": "H24P IE", "winter_efficiency_pct": 90.1, "summer_efficiency_pct": 81.1, "comparative_hot_water_efficiency_pct": 59.2, "output_kw_max": 24.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018346", "000008", "0", "2018/May/16 14:17", "Ideal Boilers", "Ideal", "LOGIC HEAT HIE", "H24P IE", "", "2018", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "90.1", "81.1", "", "59.2", "", "2", "1", "", "102", "1", "2", "42", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "92.0", "100.8", "", "", "", "", "99.1"]} +{"pcdb_id": 18347, "brand_name": "Ideal", "model_name": "LOGIC HEAT HIE", "model_qualifier": "H30P IE", "winter_efficiency_pct": 89.8, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 59.1, "output_kw_max": 30.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018347", "000008", "0", "2018/May/16 14:17", "Ideal Boilers", "Ideal", "LOGIC HEAT HIE", "H30P IE", "", "2018", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "30.3", "30.3", "", "", "89.8", "80.8", "", "59.1", "", "2", "1", "", "102", "1", "2", "31", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "91.6", "100.4", "", "", "", "", "98.7"]} +{"pcdb_id": 18348, "brand_name": "Ideal", "model_name": "VOGUE", "model_qualifier": "C26IE GEN2", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 76.2, "output_kw_max": 18.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0011, "loss_factor_f1_kwh_per_day": 0.8454, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018348", "000008", "0", "2020/Jan/22 13:00", "Ideal Boilers", "Ideal", "VOGUE", "C26IE GEN2", "47-349-47", "2018", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "18.0", "18.0", "", "", "88.6", "87.3", "", "76.2", "", "2", "", "", "104", "1", "2", "47", "3", "0", "", "", "", "0", "", "", "", "", "1", "6.915", "0.085", "0.0011", "0.8454", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.7", "97.7", "", "", "", "", "96.2"]} +{"pcdb_id": 18349, "brand_name": "Ideal", "model_name": "VOGUE", "model_qualifier": "C32IE GEN2", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 77.7, "output_kw_max": 26.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.001, "loss_factor_f1_kwh_per_day": 0.71939, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018349", "000008", "0", "2020/Jan/22 13:00", "Ideal Boilers", "Ideal", "VOGUE", "C32IE GEN2", "47-349-48", "2018", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "26.0", "26.0", "", "", "88.7", "87.3", "", "77.7", "", "2", "", "", "104", "1", "2", "63", "3", "0", "", "", "", "0", "", "", "", "", "1", "6.78", "0.086", "0.001", "0.71939", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.9", "97.8", "", "", "", "", "96.3"]} +{"pcdb_id": 18350, "brand_name": "Ideal", "model_name": "VOGUE", "model_qualifier": "C40IE GEN2", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 77.2, "output_kw_max": 32.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.001, "loss_factor_f1_kwh_per_day": 0.75466, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018350", "000008", "0", "2020/Jan/22 13:01", "Ideal Boilers", "Ideal", "VOGUE", "C40IE GEN2", "47-349-49", "2018", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "32.0", "32.0", "", "", "88.6", "87.3", "", "77.2", "", "2", "", "", "104", "1", "2", "44", "3", "0", "", "", "", "0", "", "", "", "", "1", "6.821", "0.086", "0.001", "0.75466", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.7", "97.5", "", "", "", "", "96.0"]} +{"pcdb_id": 18351, "brand_name": "Ideal", "model_name": "VOGUE", "model_qualifier": "C26P IE GEN2", "winter_efficiency_pct": 89.6, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 57.0, "output_kw_max": 18.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018351", "000008", "0", "2018/Apr/19 12:55", "Ideal Boilers", "Ideal", "VOGUE", "C26P IE GEN2", "", "2018", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "18.0", "18.0", "", "", "89.6", "81.0", "", "57.0", "", "2", "1", "", "104", "1", "2", "47", "3", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "91.7", "99.8", "", "", "", "", "98.3"]} +{"pcdb_id": 18352, "brand_name": "Ideal", "model_name": "VOGUE", "model_qualifier": "C32P IE GEN2", "winter_efficiency_pct": 89.7, "summer_efficiency_pct": 81.1, "comparative_hot_water_efficiency_pct": 57.1, "output_kw_max": 26.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018352", "000008", "0", "2018/Apr/19 12:56", "Ideal Boilers", "Ideal", "VOGUE", "C32P IE GEN2", "", "2018", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "26.0", "26.0", "", "", "89.7", "81.1", "", "57.1", "", "2", "1", "", "104", "1", "2", "63", "3", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "91.9", "100.0", "", "", "", "", "98.5"]} +{"pcdb_id": 18353, "brand_name": "Ideal", "model_name": "VOGUE", "model_qualifier": "C40P IE GEN2", "winter_efficiency_pct": 89.6, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 56.9, "output_kw_max": 32.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018353", "000008", "0", "2018/Apr/19 12:56", "Ideal Boilers", "Ideal", "VOGUE", "C40P IE GEN2", "", "2018", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "32.0", "32.0", "", "", "89.6", "81.0", "", "56.9", "", "2", "1", "", "104", "1", "2", "44", "3", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "91.7", "99.7", "", "", "", "", "98.1"]} +{"pcdb_id": 18354, "brand_name": "Ideal", "model_name": "VOGUE", "model_qualifier": "S15IE GEN2", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 15.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018354", "000008", "0", "2018/Apr/19 12:56", "Ideal Boilers", "Ideal", "VOGUE", "S15IE GEN2", "41-750-97", "2018", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "15.0", "15.0", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "25", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.6", "97.0", "", "", "", "", "95.6"]} +{"pcdb_id": 18355, "brand_name": "Ideal", "model_name": "VOGUE", "model_qualifier": "S18IE GEN2", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 18.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018355", "000008", "0", "2018/Apr/19 12:56", "Ideal Boilers", "Ideal", "VOGUE", "S18IE GEN2", "41-750-98", "2018", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18.0", "18.0", "", "", "88.7", "79.7", "", "58.2", "", "2", "", "", "102", "1", "2", "40", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.8", "97.8", "", "", "", "", "96.3"]} +{"pcdb_id": 18356, "brand_name": "Ideal", "model_name": "VOGUE", "model_qualifier": "S26IE GEN2", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 26.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018356", "000008", "0", "2018/Apr/19 12:57", "Ideal Boilers", "Ideal", "VOGUE", "S26IE GEN2", "41-750-99", "2018", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "26.0", "26.0", "", "", "88.7", "79.7", "", "58.2", "", "2", "", "", "102", "1", "2", "45", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.7", "97.8", "", "", "", "", "96.2"]} +{"pcdb_id": 18357, "brand_name": "Ideal", "model_name": "VOGUE", "model_qualifier": "S32IE GEN2", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 32.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018357", "000008", "0", "2018/Apr/19 12:57", "Ideal Boilers", "Ideal", "VOGUE", "S32IE GEN2", "41-796-01", "2018", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "32.0", "32.0", "", "", "88.7", "79.7", "", "58.2", "", "2", "", "", "102", "1", "2", "49", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.8", "97.8", "", "", "", "", "96.3"]} +{"pcdb_id": 18358, "brand_name": "Ideal", "model_name": "VOGUE", "model_qualifier": "S15P IE GEN2", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 80.4, "comparative_hot_water_efficiency_pct": 58.7, "output_kw_max": 15.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018358", "000008", "0", "2018/Apr/19 12:57", "Ideal Boilers", "Ideal", "VOGUE", "S15P IE GEN2", "", "2018", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "15.0", "15.0", "", "", "89.4", "80.4", "", "58.7", "", "2", "1", "", "102", "1", "2", "25", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "91.5", "99.2", "", "", "", "", "97.7"]} +{"pcdb_id": 18359, "brand_name": "Ideal", "model_name": "VOGUE", "model_qualifier": "S18P IE GEN2", "winter_efficiency_pct": 89.7, "summer_efficiency_pct": 80.7, "comparative_hot_water_efficiency_pct": 59.0, "output_kw_max": 18.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018359", "000008", "0", "2018/Apr/19 12:58", "Ideal Boilers", "Ideal", "VOGUE", "S18P IE GEN2", "", "2018", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "18.0", "18.0", "", "", "89.7", "80.7", "", "59.0", "", "2", "1", "", "102", "1", "2", "40", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "91.8", "100.0", "", "", "", "", "98.5"]} +{"pcdb_id": 18360, "brand_name": "Ideal", "model_name": "VOGUE", "model_qualifier": "S26P IE GEN2", "winter_efficiency_pct": 89.7, "summer_efficiency_pct": 80.7, "comparative_hot_water_efficiency_pct": 58.9, "output_kw_max": 26.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018360", "000008", "0", "2018/Apr/19 12:58", "Ideal Boilers", "Ideal", "VOGUE", "S26P IE GEN2", "", "2018", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "26.0", "26.0", "", "", "89.7", "80.7", "", "58.9", "", "2", "1", "", "102", "1", "2", "45", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "91.7", "99.9", "", "", "", "", "98.4"]} +{"pcdb_id": 18361, "brand_name": "Ideal", "model_name": "VOGUE", "model_qualifier": "S32P IE GEN2", "winter_efficiency_pct": 89.7, "summer_efficiency_pct": 80.7, "comparative_hot_water_efficiency_pct": 59.0, "output_kw_max": 32.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018361", "000008", "0", "2018/Apr/19 12:58", "Ideal Boilers", "Ideal", "VOGUE", "S32P IE GEN2", "", "2018", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "32.0", "32.0", "", "", "89.7", "80.7", "", "59.0", "", "2", "1", "", "102", "1", "2", "49", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "91.8", "100.0", "", "", "", "", "98.5"]} +{"pcdb_id": 18368, "brand_name": "Vokera BY RIELLO", "model_name": "evolve", "model_qualifier": "28C", "winter_efficiency_pct": 89.9, "summer_efficiency_pct": 81.3, "comparative_hot_water_efficiency_pct": 57.2, "output_kw_max": 24.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018368", "000011", "0", "2021/Feb/22 13:09", "Vokera", "Vokera BY RIELLO", "evolve", "28C", "40 364 57", "2017", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24.0", "24.0", "", "", "89.9", "81.3", "", "57.2", "", "2", "0", "", "104", "1", "2", "37", "3", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.4", "98.8", "", "", "", "", "97.0"]} +{"pcdb_id": 18372, "brand_name": "Ideal", "model_name": "Classic", "model_qualifier": "35", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 69.0, "output_kw_max": 24.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0023, "loss_factor_f1_kwh_per_day": 1.53009, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018372", "000008", "0", "2020/Jan/22 13:01", "Ideal Boilers", "Ideal", "Classic", "35", "86CM68", "2018", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "88.4", "87.3", "", "69.0", "", "2", "", "", "104", "1", "2", "29", "5", "0", "", "", "0", "0", "", "", "", "", "1", "7.627", "0.074", "0.0023", "1.53009", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.8", "96.9", "", "", "", "", "95.6"]} +{"pcdb_id": 18373, "brand_name": "Daikin", "model_name": "D2CND024A4AA", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 56.1, "output_kw_max": 23.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018373", "000278", "0", "2018/Sep/25 15:39", "Daikin Europe NV", "Daikin", "D2CND024A4AA", "", "47-464-08", "2017", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "23.5", "23.5", "", "", "88.3", "79.7", "", "56.1", "", "2", "", "", "104", "1", "2", "27", "3", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.3", "97.9", "", "", "", "", "95.9"]} +{"pcdb_id": 18374, "brand_name": "Daikin", "model_name": "D2CND024A4AA", "model_qualifier": "D2CND024A4AAS", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 23.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018374", "000278", "0", "2018/Sep/25 15:40", "Daikin Europe NV", "Daikin", "D2CND024A4AA", "D2CND024A4AAS", "47-464-08", "2017", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "23.5", "23.5", "", "", "88.3", "79.3", "", "58.0", "", "2", "", "", "102", "1", "2", "27", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.3", "97.9", "", "", "", "", "95.9"]} +{"pcdb_id": 18375, "brand_name": "Daikin", "model_name": "D2CND028A4AA", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 56.2, "output_kw_max": 27.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018375", "000278", "0", "2018/Sep/24 13:01", "Daikin Europe NV", "Daikin", "D2CND028A4AA", "", "47-464-10", "2017", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "27.0", "27.0", "", "", "88.5", "79.9", "", "56.2", "", "2", "", "", "104", "1", "2", "37", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "98.1", "", "", "", "", "96.2"]} +{"pcdb_id": 18376, "brand_name": "Daikin", "model_name": "D2CND028A4AA", "model_qualifier": "D2CND028A4AAS", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 27.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018376", "000278", "0", "2018/Sep/24 15:59", "Daikin Europe NV", "Daikin", "D2CND028A4AA", "D2CND028A4AAS", "47-464-10", "2017", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "27.0", "27.0", "", "", "88.5", "79.5", "", "58.1", "", "2", "", "", "102", "1", "2", "37", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "98.1", "", "", "", "", "96.2"]} +{"pcdb_id": 18377, "brand_name": "Daikin", "model_name": "D2CND035A4AA", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 56.1, "output_kw_max": 34.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018377", "000278", "0", "2018/Sep/24 13:01", "Daikin Europe NV", "Daikin", "D2CND035A4AA", "", "47-464-09", "2017", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "34.0", "34.0", "", "", "88.4", "79.8", "", "56.1", "", "2", "", "", "104", "1", "2", "37", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "97.9", "", "", "", "", "96.0"]} +{"pcdb_id": 18378, "brand_name": "Daikin", "model_name": "D2CND035A4AA", "model_qualifier": "D2CND035A4AAS", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 34.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018378", "000278", "0", "2018/Sep/24 16:00", "Daikin Europe NV", "Daikin", "D2CND035A4AA", "D2CND035A4AAS", "47-464-09", "2017", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "34.0", "34.0", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "37", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "97.9", "", "", "", "", "96.0"]} +{"pcdb_id": 18379, "brand_name": "Daikin", "model_name": "D2TND012A4AA", "model_qualifier": "", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 11.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018379", "000278", "0", "2019/Jan/14 15:06", "Daikin Europe NV", "Daikin", "D2TND012A4AA", "", "41-464-03", "2017", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "11.0", "11.0", "", "", "88.7", "79.7", "", "58.2", "", "2", "", "", "102", "1", "2", "12", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "98.7", "", "", "", "", "96.6"]} +{"pcdb_id": 18380, "brand_name": "Daikin", "model_name": "D2TND018A4AA", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 17.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018380", "000278", "0", "2019/Jan/14 15:06", "Daikin Europe NV", "Daikin", "D2TND018A4AA", "", "41-464-02", "2017", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "17.4", "17.4", "", "", "88.5", "79.5", "", "58.1", "", "2", "", "", "102", "1", "2", "19", "4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.5", "98.3", "", "", "", "", "96.2"]} +{"pcdb_id": 18381, "brand_name": "Daikin", "model_name": "D2TND024A4AA", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 23.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018381", "000278", "0", "2018/Sep/25 15:40", "Daikin Europe NV", "Daikin", "D2TND024A4AA", "", "41-464-01", "2017", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "23.5", "23.5", "", "", "88.3", "79.3", "", "58.0", "", "2", "", "", "102", "1", "2", "27", "4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.3", "97.9", "", "", "", "", "95.9"]} +{"pcdb_id": 18382, "brand_name": "Daikin", "model_name": "D2TND028A4AA", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 27.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018382", "000278", "0", "2018/Sep/25 15:40", "Daikin Europe NV", "Daikin", "D2TND028A4AA", "", "41-464-05", "2017", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "27.0", "27.0", "", "", "88.5", "79.5", "", "58.1", "", "2", "", "", "102", "1", "2", "35.6", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "98.1", "", "", "", "", "96.2"]} +{"pcdb_id": 18383, "brand_name": "Daikin", "model_name": "D2TND035A4AA", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 34.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018383", "000278", "0", "2018/Sep/25 15:39", "Daikin Europe NV", "Daikin", "D2TND035A4AA", "", "41-464-04", "2017", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "34.0", "34.0", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "54", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "97.9", "", "", "", "", "96.0"]} +{"pcdb_id": 18384, "brand_name": "Cosmogas", "model_name": "MYDENS", "model_qualifier": "24B", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 25.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018384", "000309", "0", "2018/Apr/25 09:31", "Cosmogas srl", "Cosmogas", "MYDENS", "24B", "", "2013", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "25.5", "25.5", "", "", "88.3", "79.3", "", "57.9", "", "2", "", "", "102", "1", "2", "12", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.5", "97.8", "", "", "", "", "95.8"]} +{"pcdb_id": 18385, "brand_name": "Cosmogas", "model_name": "MYDENS", "model_qualifier": "24C", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 25.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018385", "000309", "0", "2018/Apr/25 09:30", "Cosmogas srl", "Cosmogas", "MYDENS", "24C", "", "2013", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "25.5", "25.5", "", "", "88.3", "79.3", "", "57.9", "", "2", "", "", "102", "1", "2", "12", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.5", "97.8", "", "", "", "", "95.8"]} +{"pcdb_id": 18386, "brand_name": "Cosmogas", "model_name": "MYDENS", "model_qualifier": "24P", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 56.0, "output_kw_max": 25.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018386", "000309", "0", "2018/Apr/25 09:30", "Cosmogas srl", "Cosmogas", "MYDENS", "24P", "", "2013", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "25.5", "25.5", "", "", "88.3", "79.7", "", "56.0", "", "2", "", "", "104", "1", "2", "12", "5", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.5", "97.8", "", "", "", "", "95.8"]} +{"pcdb_id": 18387, "brand_name": "Cosmogas", "model_name": "MYDENS", "model_qualifier": "34B", "winter_efficiency_pct": 87.7, "summer_efficiency_pct": 78.7, "comparative_hot_water_efficiency_pct": 57.5, "output_kw_max": 32.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018387", "000309", "0", "2018/Apr/25 09:29", "Cosmogas srl", "Cosmogas", "MYDENS", "34B", "", "2013", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "32.0", "32.0", "", "", "87.7", "78.7", "", "57.5", "", "2", "", "", "102", "1", "2", "12", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.1", "96.4", "", "", "", "", "94.6"]} +{"pcdb_id": 18388, "brand_name": "Cosmogas", "model_name": "MYDENS", "model_qualifier": "34C", "winter_efficiency_pct": 87.7, "summer_efficiency_pct": 78.7, "comparative_hot_water_efficiency_pct": 57.5, "output_kw_max": 32.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018388", "000309", "0", "2018/Apr/25 09:28", "Cosmogas srl", "Cosmogas", "MYDENS", "34C", "", "2013", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "32.0", "32.0", "", "", "87.7", "78.7", "", "57.5", "", "2", "", "", "102", "1", "2", "12", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.1", "96.4", "", "", "", "", "94.6"]} +{"pcdb_id": 18389, "brand_name": "Cosmogas", "model_name": "MYDENS", "model_qualifier": "34P", "winter_efficiency_pct": 87.7, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 55.6, "output_kw_max": 32.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018389", "000309", "0", "2018/Apr/25 09:25", "Cosmogas srl", "Cosmogas", "MYDENS", "34P", "", "2013", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "32.0", "32.0", "", "", "87.7", "79.1", "", "55.6", "", "2", "", "", "104", "1", "2", "12", "5", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.1", "96.4", "", "", "", "", "94.6"]} +{"pcdb_id": 18390, "brand_name": "Cosmogas", "model_name": "MYDENS", "model_qualifier": "60C", "winter_efficiency_pct": 87.8, "summer_efficiency_pct": 78.8, "comparative_hot_water_efficiency_pct": 57.5, "output_kw_max": 57.8, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018390", "000309", "0", "2018/Apr/25 09:44", "Cosmogas srl", "Cosmogas", "MYDENS", "60C", "", "2013", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "57.8", "57.8", "", "", "87.8", "78.8", "", "57.5", "", "2", "", "", "102", "1", "2", "24", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.5", "96.4", "", "", "", "", "94.7"]} +{"pcdb_id": 18391, "brand_name": "Ariston", "model_name": "CLAS ONE 24", "model_qualifier": "", "winter_efficiency_pct": 89.7, "summer_efficiency_pct": 81.1, "comparative_hot_water_efficiency_pct": 57.1, "output_kw_max": 21.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018391", "000080", "0", "2018/Dec/12 10:42", "Ariston Thermo S.p.A", "Ariston", "CLAS ONE 24", "", "3301043", "2017", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "21.4", "21.4", "", "", "89.7", "81.1", "", "57.1", "", "2", "0", "", "104", "1", "2", "30", "4", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0805", "", "", "", "", "", "", "", "", "89.4", "98.5", "", "", "", "", "96.7"]} +{"pcdb_id": 18394, "brand_name": "Vokera BY RIELLO", "model_name": "Easi-Heat Plus", "model_qualifier": "24S", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 24.18, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018394", "000011", "0", "2019/Mar/06 09:44", "Vokera", "Vokera BY RIELLO", "Easi-Heat Plus", "24S", "20136547", "2017", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24.18", "24.18", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "43", "6", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.0", "97.2", "", "", "", "", "95.3"]} +{"pcdb_id": 18395, "brand_name": "Vokera BY RIELLO", "model_name": "Easi-Heat Plus", "model_qualifier": "30S", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 28.1, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018395", "000011", "0", "2019/Mar/06 09:44", "Vokera", "Vokera BY RIELLO", "Easi-Heat Plus", "30S", "20136551", "2017", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "28.1", "28.1", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "50", "6", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "86.9", "97.3", "", "", "", "", "95.3"]} +{"pcdb_id": 18396, "brand_name": "Vokera BY RIELLO", "model_name": "Easi-Heat Plus", "model_qualifier": "18V", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 19.68, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018396", "000011", "0", "2019/Jan/17 13:49", "Vokera", "Vokera BY RIELLO", "Easi-Heat Plus", "18V", "20136845", "2017", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "19.68", "19.68", "", "", "88.2", "79.2", "", "57.8", "", "2", "", "", "102", "1", "2", "75", "4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "97.3", "", "", "", "", "95.5"]} +{"pcdb_id": 18397, "brand_name": "Vaillant", "model_name": "ecoTEC exclusive 627", "model_qualifier": "VU 256/5-7 (H-GB)", "winter_efficiency_pct": 89.6, "summer_efficiency_pct": 80.6, "comparative_hot_water_efficiency_pct": 58.9, "output_kw_max": 25.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018397", "000031", "0", "2018/Aug/21 09:27", "Vaillant", "Vaillant", "ecoTEC exclusive 627", "VU 256/5-7 (H-GB)", "41-694-02", "2016", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "25.0", "25.0", "", "", "89.6", "80.6", "", "58.9", "", "2", "0", "", "102", "1", "2", "32", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0045", "", "", "", "", "", "", "", "", "89.5", "98.0", "", "", "", "", "96.4"]} +{"pcdb_id": 18398, "brand_name": "Vaillant", "model_name": "ecoTEC exclusive 835", "model_qualifier": "VUW 356/5-7 (H-GB)", "winter_efficiency_pct": 89.6, "summer_efficiency_pct": 88.6, "comparative_hot_water_efficiency_pct": 86.0, "output_kw_max": 25.0, "final_year_of_manufacture": null, "subsidiary_type": 1, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0051, "loss_factor_f1_kwh_per_day": 0.14701, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018398", "000031", "0", "2020/Jan/22 13:02", "Vaillant", "Vaillant", "ecoTEC exclusive 835", "VUW 356/5-7 (H-GB)", "47-044-66", "2016", "current", "2", "2", "1", "2", "1", "", "", "2", "2", "2", "25", "25", "", "", "89.6", "88.6", "", "86.0", "", "2", "0", "", "104", "1", "2", "31", "2", "0", "", "", "", "0", "", "", "", "", "1", "6.256", "0.074", "0.0051", "0.14701", "", "", "", "", "", "3", "1", "", "0045", "", "", "", "", "", "", "", "", "90.1", "97.8", "", "", "", "", "96.3"]} +{"pcdb_id": 18399, "brand_name": "Vaillant", "model_name": "ecoTEC exclusive 843", "model_qualifier": "VUW 436/5-7 (H-GB)", "winter_efficiency_pct": 89.8, "summer_efficiency_pct": 88.7, "comparative_hot_water_efficiency_pct": 86.4, "output_kw_max": 33.0, "final_year_of_manufacture": null, "subsidiary_type": 1, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.006, "loss_factor_f1_kwh_per_day": 0.12351, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018399", "000031", "0", "2020/Jan/22 13:02", "Vaillant", "Vaillant", "ecoTEC exclusive 843", "VUW 436/5-7 (H-GB)", "47-044-67", "2016", "current", "2", "2", "1", "2", "1", "", "", "2", "2", "2", "33", "33", "", "", "89.8", "88.7", "", "86.4", "", "2", "0", "", "104", "1", "2", "45", "2", "0", "", "", "", "0", "", "", "", "", "1", "6.231", "0.092", "0.006", "0.12351", "", "", "", "", "", "3", "1", "", "0045", "", "", "", "", "", "", "", "", "90.4", "98.3", "", "", "", "", "96.8"]} +{"pcdb_id": 18400, "brand_name": "Vaillant", "model_name": "ecoFIT sustain 415", "model_qualifier": "VU 156/6-3 OV (H-GB)", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 15.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018400", "000031", "0", "2018/Jun/27 11:01", "Vaillant", "Vaillant", "ecoFIT sustain 415", "VU 156/6-3 OV (H-GB)", "41-694-33", "2018", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "15.3", "15.3", "", "", "89.1", "80.1", "", "58.5", "", "2", "", "", "102", "1", "2", "24", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0045", "", "", "", "", "", "", "", "", "89.1", "99.1", "", "", "", "", "97.2"]} +{"pcdb_id": 18401, "brand_name": "Vaillant", "model_name": "ecoFIT sustain 418", "model_qualifier": "VU 186/6-3 OV (H-GB)", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 18.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018401", "000031", "0", "2018/Jun/27 11:02", "Vaillant", "Vaillant", "ecoFIT sustain 418", "VU 186/6-3 OV (H-GB)", "41-694-34", "2018", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18.4", "18.4", "", "", "89.0", "80.0", "", "58.4", "", "2", "", "", "102", "1", "2", "25", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0045", "", "", "", "", "", "", "", "", "89.0", "98.9", "", "", "", "", "97.0"]} +{"pcdb_id": 18402, "brand_name": "Vaillant", "model_name": "ecoFIT sustain 430", "model_qualifier": "VU 306/6-3 OV (H-GB)", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 25.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018402", "000031", "0", "2018/Jun/27 11:03", "Vaillant", "Vaillant", "ecoFIT sustain 430", "VU 306/6-3 OV (H-GB)", "41-694-35", "2018", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "25.5", "25.5", "", "", "89.1", "80.1", "", "58.5", "", "2", "", "", "102", "1", "2", "37", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0045", "", "", "", "", "", "", "", "", "89.5", "99.0", "", "", "", "", "97.2"]} +{"pcdb_id": 18403, "brand_name": "Vaillant", "model_name": "ecoFIT sustain 615", "model_qualifier": "VU 156/6-3 (H-GB)", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 15.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018403", "000031", "0", "2018/Jun/27 11:03", "Vaillant", "Vaillant", "ecoFIT sustain 615", "VU 156/6-3 (H-GB)", "41-694-30", "2018", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "15.3", "15.3", "", "", "89.1", "80.1", "", "58.5", "", "2", "", "", "102", "1", "2", "24", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0045", "", "", "", "", "", "", "", "", "89.1", "99.1", "", "", "", "", "97.2"]} +{"pcdb_id": 18404, "brand_name": "Vaillant", "model_name": "ecoFIT sustain 618", "model_qualifier": "VU186/6-3 (H-GB)", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 18.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018404", "000031", "0", "2018/Jun/27 11:03", "Vaillant", "Vaillant", "ecoFIT sustain 618", "VU186/6-3 (H-GB)", "41-694-31", "2018", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18.4", "18.4", "", "", "89.0", "80.0", "", "58.4", "", "2", "", "", "102", "1", "2", "25", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0045", "", "", "", "", "", "", "", "", "89.0", "98.9", "", "", "", "", "97.0"]} +{"pcdb_id": 18405, "brand_name": "Vaillant", "model_name": "ecoFIT sustain 630", "model_qualifier": "VU 306/6-3 (H-GB)", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 25.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018405", "000031", "0", "2018/Jun/27 11:03", "Vaillant", "Vaillant", "ecoFIT sustain 630", "VU 306/6-3 (H-GB)", "41-694-32", "2018", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "25.5", "25.5", "", "", "89.1", "80.1", "", "58.5", "", "2", "", "", "102", "1", "2", "37", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0045", "", "", "", "", "", "", "", "", "89.5", "99.0", "", "", "", "", "97.2"]} +{"pcdb_id": 18406, "brand_name": "Worcester", "model_name": "GREENSTAR DANESMOOR", "model_qualifier": "12/18 ErP+", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 18.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018406", "000035", "0", "2018/Aug/13 14:15", "Bosch Thermotechnology", "Worcester", "GREENSTAR DANESMOOR", "12/18 ErP+", "", "2018", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "12", "18", "", "", "87.9", "80.1", "", "58.5", "", "2", "", "", "201", "1", "1", "158", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "92.0", "94.0", "", "", "", "", "93.6"]} +{"pcdb_id": 18407, "brand_name": "Worcester", "model_name": "GREENSTAR DANESMOOR EXTERNAL", "model_qualifier": "12/18 ErP+", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 18.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018407", "000035", "0", "2018/Aug/13 14:16", "Bosch Thermotechnology", "Worcester", "GREENSTAR DANESMOOR EXTERNAL", "12/18 ErP+", "", "2018", "current", "4", "1", "2", "1", "0", "", "", "2", "2", "2", "12", "18", "", "", "87.9", "80.1", "", "58.5", "", "2", "", "", "201", "1", "1", "158", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "92.0", "94.0", "", "", "", "", "93.6"]} +{"pcdb_id": 18408, "brand_name": "Worcester", "model_name": "GREENSTAR DANESMOOR UTILITY", "model_qualifier": "12/18 ErP+", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 18.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018408", "000035", "0", "2018/Aug/13 14:16", "Bosch Thermotechnology", "Worcester", "GREENSTAR DANESMOOR UTILITY", "12/18 ErP+", "", "2018", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "12", "18", "", "", "87.9", "80.1", "", "58.5", "", "2", "", "", "201", "1", "1", "158", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "92.0", "94.0", "", "", "", "", "93.6"]} +{"pcdb_id": 18409, "brand_name": "Worcester", "model_name": "GREENSTAR DANESMOOR SYSTEM UTY", "model_qualifier": "12/18 ErP+", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 18.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018409", "000035", "0", "2018/Aug/13 14:16", "Bosch Thermotechnology", "Worcester", "GREENSTAR DANESMOOR SYSTEM UTY", "12/18 ErP+", "", "2018", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "12", "18", "", "", "87.9", "80.1", "", "58.5", "", "2", "", "", "201", "1", "1", "158", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "92.0", "94.0", "", "", "", "", "93.6"]} +{"pcdb_id": 18410, "brand_name": "Worcester", "model_name": "GREENSTAR DANESMOOR SYSTEM EXTERNAL", "model_qualifier": "12/18 ErP+", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 18.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018410", "000035", "0", "2018/Aug/13 14:17", "Bosch Thermotechnology", "Worcester", "GREENSTAR DANESMOOR SYSTEM EXTERNAL", "12/18 ErP+", "", "2018", "current", "4", "1", "2", "1", "0", "", "", "2", "2", "2", "12", "18", "", "", "87.9", "80.1", "", "58.5", "", "2", "", "", "201", "1", "1", "158", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "92.0", "94.0", "", "", "", "", "93.6"]} +{"pcdb_id": 18411, "brand_name": "Worcester", "model_name": "GREENSTAR DANESMOOR SYSTEM", "model_qualifier": "12/18 ErP+", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 18.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018411", "000035", "0", "2018/Aug/13 14:17", "Bosch Thermotechnology", "Worcester", "GREENSTAR DANESMOOR SYSTEM", "12/18 ErP+", "", "2018", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "12", "18", "", "", "87.9", "80.1", "", "58.5", "", "2", "", "", "201", "1", "1", "158", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "92.0", "94.0", "", "", "", "", "93.6"]} +{"pcdb_id": 18412, "brand_name": "Worcester", "model_name": "GREENSTAR HEATSLAVE II", "model_qualifier": "12/18 ErP+", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 81.8, "comparative_hot_water_efficiency_pct": 42.6, "output_kw_max": 18.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 1, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018412", "000035", "0", "2024/Jan/31 10:17", "Bosch Thermotechnology", "Worcester", "GREENSTAR HEATSLAVE II", "12/18 ErP+", "", "2018", "current", "4", "1", "1", "2", "0", "", "", "2", "3", "2", "12", "18", "", "", "87.9", "81.8", "", "42.6", "", "2", "", "", "203", "1", "1", "156", "2", "1", "1", "", "62", "0", "25", "3", "84", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "92.0", "94.0", "", "", "", "", "93.6"]} +{"pcdb_id": 18413, "brand_name": "Worcester", "model_name": "GREENSTAR HEATSLAVE II EXT", "model_qualifier": "12/18 ErP+", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 81.8, "comparative_hot_water_efficiency_pct": 42.6, "output_kw_max": 18.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 1, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018413", "000035", "0", "2024/Jan/31 10:17", "Bosch Thermotechnology", "Worcester", "GREENSTAR HEATSLAVE II EXT", "12/18 ErP+", "", "2018", "current", "4", "1", "2", "2", "0", "", "", "2", "2", "2", "12", "18", "", "", "87.9", "81.8", "", "42.6", "", "2", "", "", "203", "1", "1", "156", "2", "1", "1", "", "62", "0", "25", "3", "84", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "92.0", "94.0", "", "", "", "", "93.6"]} +{"pcdb_id": 18414, "brand_name": "Worcester", "model_name": "GREENSTAR HEATSLAVE II EXTERNAL", "model_qualifier": "18/25 ErP+", "winter_efficiency_pct": 87.8, "summer_efficiency_pct": 81.7, "comparative_hot_water_efficiency_pct": 42.4, "output_kw_max": 25.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 1, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018414", "000035", "0", "2024/Jan/31 10:17", "Bosch Thermotechnology", "Worcester", "GREENSTAR HEATSLAVE II EXTERNAL", "18/25 ErP+", "", "2018", "current", "4", "1", "2", "2", "0", "", "", "2", "2", "2", "18", "25", "", "", "87.8", "81.7", "", "42.4", "", "2", "", "", "203", "1", "1", "145", "2", "1", "1", "", "63", "0", "25", "3", "86", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.9", "93.8", "", "", "", "", "93.4"]} +{"pcdb_id": 18415, "brand_name": "Worcester", "model_name": "GREENSTAR HEATSLAVE II", "model_qualifier": "18/25 ErP+", "winter_efficiency_pct": 87.8, "summer_efficiency_pct": 81.7, "comparative_hot_water_efficiency_pct": 42.4, "output_kw_max": 25.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 1, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018415", "000035", "0", "2024/Jan/31 10:17", "Bosch Thermotechnology", "Worcester", "GREENSTAR HEATSLAVE II", "18/25 ErP+", "", "2018", "current", "4", "1", "1", "2", "0", "", "", "2", "3", "2", "18", "25", "", "", "87.8", "81.7", "", "42.4", "", "2", "", "", "203", "1", "1", "145", "2", "1", "1", "", "63", "0", "25", "3", "86", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.9", "93.8", "", "", "", "", "93.4"]} +{"pcdb_id": 18416, "brand_name": "Worcester", "model_name": "GREENSTAR DANESMOOR", "model_qualifier": "18/25 ErP+", "winter_efficiency_pct": 87.8, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 25.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018416", "000035", "0", "2018/Aug/13 14:18", "Bosch Thermotechnology", "Worcester", "GREENSTAR DANESMOOR", "18/25 ErP+", "", "2018", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "18", "25", "", "", "87.8", "80.0", "", "58.4", "", "2", "", "", "201", "1", "1", "152", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.9", "93.8", "", "", "", "", "93.4"]} +{"pcdb_id": 18417, "brand_name": "Worcester", "model_name": "GREENSTAR DANESMOOR EXTERNAL", "model_qualifier": "18/25 ErP+", "winter_efficiency_pct": 87.8, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 25.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018417", "000035", "0", "2018/Aug/13 14:19", "Bosch Thermotechnology", "Worcester", "GREENSTAR DANESMOOR EXTERNAL", "18/25 ErP+", "", "2018", "current", "4", "1", "2", "1", "0", "", "", "2", "2", "2", "18", "25", "", "", "87.8", "80.0", "", "58.4", "", "2", "", "", "201", "1", "1", "152", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.9", "93.8", "", "", "", "", "93.4"]} +{"pcdb_id": 18418, "brand_name": "Worcester", "model_name": "GREENSTAR DANESMOOR SYSTEM EXTERNAL", "model_qualifier": "18/25 ErP+", "winter_efficiency_pct": 87.8, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 25.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018418", "000035", "0", "2018/Aug/13 14:19", "Bosch Thermotechnology", "Worcester", "GREENSTAR DANESMOOR SYSTEM EXTERNAL", "18/25 ErP+", "", "2018", "current", "4", "1", "2", "1", "0", "", "", "2", "2", "2", "18", "25", "", "", "87.8", "80.0", "", "58.4", "", "2", "", "", "201", "1", "1", "152", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.9", "93.8", "", "", "", "", "93.4"]} +{"pcdb_id": 18419, "brand_name": "Worcester", "model_name": "GREENSTAR DANESMOOR SYSTEM", "model_qualifier": "18/25 ErP+", "winter_efficiency_pct": 87.8, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 25.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018419", "000035", "0", "2018/Aug/13 14:19", "Bosch Thermotechnology", "Worcester", "GREENSTAR DANESMOOR SYSTEM", "18/25 ErP+", "", "2018", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "18", "25", "", "", "87.8", "80.0", "", "58.4", "", "2", "", "", "201", "1", "1", "152", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.9", "93.8", "", "", "", "", "93.4"]} +{"pcdb_id": 18420, "brand_name": "Worcester", "model_name": "GREENSTAR DANESMOOR UTILITY", "model_qualifier": "18/25 ErP+", "winter_efficiency_pct": 87.8, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 25.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018420", "000035", "0", "2018/Aug/13 14:19", "Bosch Thermotechnology", "Worcester", "GREENSTAR DANESMOOR UTILITY", "18/25 ErP+", "", "2018", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "18", "25", "", "", "87.8", "80.0", "", "58.4", "", "2", "", "", "201", "1", "1", "152", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.9", "93.8", "", "", "", "", "93.4"]} +{"pcdb_id": 18421, "brand_name": "Worcester", "model_name": "GREENSTAR DANESMOOR SYSTEM UTY", "model_qualifier": "18/25 ErP+", "winter_efficiency_pct": 87.8, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 25.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018421", "000035", "0", "2018/Aug/13 14:20", "Bosch Thermotechnology", "Worcester", "GREENSTAR DANESMOOR SYSTEM UTY", "18/25 ErP+", "", "2018", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "18", "25", "", "", "87.8", "80.0", "", "58.4", "", "2", "", "", "201", "1", "1", "152", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.9", "93.8", "", "", "", "", "93.4"]} +{"pcdb_id": 18422, "brand_name": "Worcester", "model_name": "GREENSTAR HEATSLAVE II", "model_qualifier": "25/32 ErP+", "winter_efficiency_pct": 87.7, "summer_efficiency_pct": 81.6, "comparative_hot_water_efficiency_pct": 42.2, "output_kw_max": 32.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 1, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018422", "000035", "0", "2024/Jan/31 10:17", "Bosch Thermotechnology", "Worcester", "GREENSTAR HEATSLAVE II", "25/32 ErP+", "", "2018", "current", "4", "1", "1", "2", "0", "", "", "2", "3", "2", "25", "32", "", "", "87.7", "81.6", "", "42.2", "", "2", "", "", "203", "1", "1", "144", "2", "1", "1", "", "64", "0", "25", "3", "88", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.7", "93.7", "", "", "", "", "93.3"]} +{"pcdb_id": 18423, "brand_name": "Worcester", "model_name": "GREENSTAR HEATSLAVE II EXTERNAL", "model_qualifier": "25/32 ErP+", "winter_efficiency_pct": 87.7, "summer_efficiency_pct": 81.6, "comparative_hot_water_efficiency_pct": 42.2, "output_kw_max": 32.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 1, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018423", "000035", "0", "2024/Jan/31 10:17", "Bosch Thermotechnology", "Worcester", "GREENSTAR HEATSLAVE II EXTERNAL", "25/32 ErP+", "", "2018", "current", "4", "1", "2", "2", "0", "", "", "2", "2", "2", "25", "32", "", "", "87.7", "81.6", "", "42.2", "", "2", "", "", "203", "1", "1", "144", "2", "1", "1", "", "64", "0", "25", "3", "88", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.7", "93.7", "", "", "", "", "93.3"]} +{"pcdb_id": 18424, "brand_name": "Worcester", "model_name": "GREENSTAR DANESMOOR", "model_qualifier": "25/32 ErP+", "winter_efficiency_pct": 87.7, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 32.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018424", "000035", "0", "2018/Aug/13 14:21", "Bosch Thermotechnology", "Worcester", "GREENSTAR DANESMOOR", "25/32 ErP+", "", "2018", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "25", "32", "", "", "87.7", "79.9", "", "58.4", "", "2", "", "", "201", "1", "1", "147", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.7", "93.7", "", "", "", "", "93.3"]} +{"pcdb_id": 18425, "brand_name": "Worcester", "model_name": "GREENSTAR DANESMOOR EXTERNAL", "model_qualifier": "25/32 ErP+", "winter_efficiency_pct": 87.7, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 32.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018425", "000035", "0", "2018/Aug/13 14:21", "Bosch Thermotechnology", "Worcester", "GREENSTAR DANESMOOR EXTERNAL", "25/32 ErP+", "", "2018", "current", "4", "1", "2", "1", "0", "", "", "2", "2", "2", "25", "32", "", "", "87.7", "79.9", "", "58.4", "", "2", "", "", "201", "1", "1", "147", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.7", "93.7", "", "", "", "", "93.3"]} +{"pcdb_id": 18426, "brand_name": "Worcester", "model_name": "GREENSTAR DANESMOOR SYSTEM EXTERNAL", "model_qualifier": "25/32 ErP+", "winter_efficiency_pct": 87.7, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 32.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018426", "000035", "0", "2018/Aug/13 14:21", "Bosch Thermotechnology", "Worcester", "GREENSTAR DANESMOOR SYSTEM EXTERNAL", "25/32 ErP+", "", "2018", "current", "4", "1", "2", "1", "0", "", "", "2", "2", "2", "25", "32", "", "", "87.7", "79.9", "", "58.4", "", "2", "", "", "201", "1", "1", "147", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.7", "93.7", "", "", "", "", "93.3"]} +{"pcdb_id": 18427, "brand_name": "Worcester", "model_name": "GREENSTAR DANESMOOR SYSTEM", "model_qualifier": "25/32 ErP+", "winter_efficiency_pct": 87.7, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 32.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018427", "000035", "0", "2018/Aug/13 14:22", "Bosch Thermotechnology", "Worcester", "GREENSTAR DANESMOOR SYSTEM", "25/32 ErP+", "", "2018", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "25", "32", "", "", "87.7", "79.9", "", "58.4", "", "2", "", "", "201", "1", "1", "147", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.7", "93.7", "", "", "", "", "93.3"]} +{"pcdb_id": 18428, "brand_name": "Worcester", "model_name": "GREENSTAR DANESMOOR UTILITY", "model_qualifier": "25/32 ErP+", "winter_efficiency_pct": 87.7, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 32.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018428", "000035", "0", "2018/Aug/13 14:22", "Bosch Thermotechnology", "Worcester", "GREENSTAR DANESMOOR UTILITY", "25/32 ErP+", "", "2018", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "25", "32", "", "", "87.7", "79.9", "", "58.4", "", "2", "", "", "201", "1", "1", "147", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.7", "93.7", "", "", "", "", "93.3"]} +{"pcdb_id": 18429, "brand_name": "Worcester", "model_name": "GREENSTAR DANESMOOR SYSTEM UTY", "model_qualifier": "25/32 ErP+", "winter_efficiency_pct": 87.7, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 32.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018429", "000035", "0", "2018/Aug/13 14:22", "Bosch Thermotechnology", "Worcester", "GREENSTAR DANESMOOR SYSTEM UTY", "25/32 ErP+", "", "2018", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "25", "32", "", "", "87.7", "79.9", "", "58.4", "", "2", "", "", "201", "1", "1", "147", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.7", "93.7", "", "", "", "", "93.3"]} +{"pcdb_id": 18430, "brand_name": "Worcester", "model_name": "GREENSTAR", "model_qualifier": "9Ri ErP+", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 9.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018430", "000035", "0", "2018/Aug/13 09:14", "Bosch Thermotechnology", "Worcester", "GREENSTAR", "9Ri ErP+", "41-406-74", "2018", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "9.0", "9.0", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "25", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.2", "98.1", "", "", "", "", "96.0"]} +{"pcdb_id": 18431, "brand_name": "Worcester", "model_name": "GREENSTAR", "model_qualifier": "12Ri ErP+", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 12.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018431", "000035", "0", "2018/Aug/13 09:14", "Bosch Thermotechnology", "Worcester", "GREENSTAR", "12Ri ErP+", "41-406-75", "2018", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "12", "12", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "33", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.2", "98.1", "", "", "", "", "96.0"]} +{"pcdb_id": 18432, "brand_name": "Worcester", "model_name": "GREENSTAR", "model_qualifier": "15Ri ErP+", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 15.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018432", "000035", "0", "2018/Aug/13 09:15", "Bosch Thermotechnology", "Worcester", "GREENSTAR", "15Ri ErP+", "41-406-76", "2018", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "15", "15", "", "", "88.1", "79.1", "", "57.8", "", "2", "", "", "102", "1", "2", "44", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "86.9", "97.6", "", "", "", "", "95.6"]} +{"pcdb_id": 18433, "brand_name": "Worcester", "model_name": "GREENSTAR", "model_qualifier": "18Ri ErP+", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 18.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018433", "000035", "0", "2018/Aug/13 09:15", "Bosch Thermotechnology", "Worcester", "GREENSTAR", "18Ri ErP+", "41-406-77", "2018", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18", "18", "", "", "88.1", "79.1", "", "57.8", "", "2", "", "", "102", "1", "2", "49", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "86.9", "97.6", "", "", "", "", "95.6"]} +{"pcdb_id": 18434, "brand_name": "Worcester", "model_name": "GREENSTAR", "model_qualifier": "21Ri ErP+", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 21.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018434", "000035", "0", "2018/Aug/13 09:16", "Bosch Thermotechnology", "Worcester", "GREENSTAR", "21Ri ErP+", "41-406-78", "2018", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "21", "21", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "42", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "86.8", "97.2", "", "", "", "", "95.2"]} +{"pcdb_id": 18435, "brand_name": "Worcester", "model_name": "GREENSTAR", "model_qualifier": "24Ri ErP+", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 24.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018435", "000035", "0", "2018/Aug/13 09:16", "Bosch Thermotechnology", "Worcester", "GREENSTAR", "24Ri ErP+", "41-406-79", "2018", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24", "24", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "51", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "86.8", "97.2", "", "", "", "", "95.2"]} +{"pcdb_id": 18436, "brand_name": "Worcester", "model_name": "GREENSTAR", "model_qualifier": "9Ri ErP+ LPG", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 9.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018436", "000035", "0", "2018/Sep/05 10:10", "Bosch Thermotechnology", "Worcester", "GREENSTAR", "9Ri ErP+ LPG", "41-406-68", "2018", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "9", "9", "", "", "88.3", "79.3", "", "57.9", "", "2", "0", "", "102", "1", "2", "26", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.5", "94.8", "", "", "", "", "93.8"]} +{"pcdb_id": 18437, "brand_name": "Worcester", "model_name": "GREENSTAR", "model_qualifier": "12Ri ErP+ LPG", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 12.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018437", "000035", "0", "2018/Sep/05 10:10", "Bosch Thermotechnology", "Worcester", "GREENSTAR", "12Ri ErP+ LPG", "41-406-69", "2018", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "12", "12", "", "", "88.3", "79.3", "", "57.9", "", "2", "0", "", "102", "1", "2", "36", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.5", "94.8", "", "", "", "", "93.8"]} +{"pcdb_id": 18438, "brand_name": "Worcester", "model_name": "GREENSTAR", "model_qualifier": "15Ri ErP+ LPG", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 15.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018438", "000035", "0", "2018/Sep/05 10:11", "Bosch Thermotechnology", "Worcester", "GREENSTAR", "15Ri ErP+ LPG", "41-406-70", "2018", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "15", "15", "", "", "88.4", "79.4", "", "58.0", "", "2", "0", "", "102", "1", "2", "52", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.0", "95.0", "", "", "", "", "94.0"]} +{"pcdb_id": 18439, "brand_name": "Worcester", "model_name": "GREENSTAR", "model_qualifier": "18Ri ErP+ LPG", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 18.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018439", "000035", "0", "2018/Sep/05 10:11", "Bosch Thermotechnology", "Worcester", "GREENSTAR", "18Ri ErP+ LPG", "41-406-71", "2018", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "18", "18", "", "", "88.5", "79.5", "", "58.1", "", "2", "0", "", "102", "1", "2", "55", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.7", "95.1", "", "", "", "", "94.1"]} +{"pcdb_id": 18440, "brand_name": "Worcester", "model_name": "GREENSTAR", "model_qualifier": "21Ri ErP+ LPG", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 21.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018440", "000035", "0", "2018/Sep/05 10:11", "Bosch Thermotechnology", "Worcester", "GREENSTAR", "21Ri ErP+ LPG", "41-406-72", "2018", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "21", "21", "", "", "88.2", "79.2", "", "57.8", "", "2", "0", "", "102", "1", "2", "44", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.7", "94.3", "", "", "", "", "93.4"]} +{"pcdb_id": 18441, "brand_name": "Worcester", "model_name": "GREENSTAR", "model_qualifier": "24Ri ErP+ LPG", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 24.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018441", "000035", "0", "2018/Sep/05 10:11", "Bosch Thermotechnology", "Worcester", "GREENSTAR", "24Ri ErP+ LPG", "41-406-73", "2018", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "24", "24", "", "", "88.2", "79.2", "", "57.8", "", "2", "0", "", "102", "1", "2", "54", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.7", "94.3", "", "", "", "", "93.4"]} +{"pcdb_id": 18442, "brand_name": "Worcester", "model_name": "Greenstar 8000 Style", "model_qualifier": "GR8700iW 30 C NG", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 88.2, "comparative_hot_water_efficiency_pct": 73.5, "output_kw_max": 29.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.001, "loss_factor_f1_kwh_per_day": 1.05319, "loss_factor_f2_kwh_per_day": 1.02566, "rejected_factor_f3_per_litre": 0.0, "raw": ["018442", "000035", "0", "2020/Jul/27 16:45", "Bosch Thermotechnology", "Worcester", "Greenstar 8000 Style", "GR8700iW 30 C NG", "47-800-03", "2018", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "29.5", "29.5", "", "", "88.8", "88.2", "", "73.5", "", "2", "", "", "104", "1", "2", "67", "1", "0", "", "", "", "0", "", "", "", "", "2", "7.168", "0.098", "0.001", "1.05319", "13.007", "0.118", "0.001", "1.02566", "0.0", "", "", "", "8325", "", "", "", "", "", "", "", "", "88.3", "98.7", "", "", "", "", "96.7"]} +{"pcdb_id": 18443, "brand_name": "Worcester", "model_name": "Greenstar 8000 Style", "model_qualifier": "GR8700iW 35 C NG", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 88.2, "comparative_hot_water_efficiency_pct": 75.1, "output_kw_max": 33.7, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.0045, "loss_factor_f1_kwh_per_day": 0.84809, "loss_factor_f2_kwh_per_day": 0.85555, "rejected_factor_f3_per_litre": 4e-05, "raw": ["018443", "000035", "0", "2020/Jul/27 16:39", "Bosch Thermotechnology", "Worcester", "Greenstar 8000 Style", "GR8700iW 35 C NG", "47-800-02", "2018", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "33.7", "33.7", "", "", "88.6", "88.2", "", "75.1", "", "2", "", "", "104", "1", "2", "48", "1", "0", "", "", "", "0", "", "", "", "", "2", "7.012", "0.103", "0.0045", "0.84809", "12.813", "0.118", "0.0005", "0.85555", "0.00004", "", "", "", "8325", "", "", "", "", "", "", "", "", "86.9", "98.8", "", "", "", "", "96.6"]} +{"pcdb_id": 18444, "brand_name": "Worcester", "model_name": "Greenstar 8000 Style", "model_qualifier": "GR8700iW 40 C NG", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 88.2, "comparative_hot_water_efficiency_pct": 73.4, "output_kw_max": 33.7, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.001, "loss_factor_f1_kwh_per_day": 1.03647, "loss_factor_f2_kwh_per_day": 1.03238, "rejected_factor_f3_per_litre": 1e-05, "raw": ["018444", "000035", "0", "2020/Jul/27 16:56", "Bosch Thermotechnology", "Worcester", "Greenstar 8000 Style", "GR8700iW 40 C NG", "47-800-01", "2018", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "33.7", "33.7", "", "", "88.7", "88.2", "", "73.4", "", "2", "", "", "104", "1", "2", "48", "1", "0", "", "", "", "0", "", "", "", "", "2", "7.175", "0.107", "0.001", "1.03647", "13.05", "0.126", "0.0005", "1.03238", "0.00001", "", "", "", "8325", "", "", "", "", "", "", "", "", "87.4", "98.7", "", "", "", "", "96.6"]} +{"pcdb_id": 18445, "brand_name": "Worcester", "model_name": "Greenstar 8000 Style", "model_qualifier": "GR8700iW 45 C NG", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 88.2, "comparative_hot_water_efficiency_pct": 74.1, "output_kw_max": 33.7, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.0075, "loss_factor_f1_kwh_per_day": 0.96653, "loss_factor_f2_kwh_per_day": 0.92531, "rejected_factor_f3_per_litre": 4e-05, "raw": ["018445", "000035", "0", "2020/Jul/27 17:02", "Bosch Thermotechnology", "Worcester", "Greenstar 8000 Style", "GR8700iW 45 C NG", "47-406-99", "2018", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "33.7", "33.7", "", "", "88.9", "88.2", "", "74.1", "", "2", "", "", "104", "1", "2", "48", "1", "0", "", "", "", "0", "", "", "", "", "2", "7.103", "0.104", "0.0075", "0.96653", "12.953", "0.121", "0.0035", "0.92531", "0.00004", "", "", "", "8325", "", "", "", "", "", "", "", "", "88.8", "98.8", "", "", "", "", "96.9"]} +{"pcdb_id": 18446, "brand_name": "Worcester", "model_name": "Greenstar 8000 Style", "model_qualifier": "GR8700iW 50 C NG", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 88.2, "comparative_hot_water_efficiency_pct": 74.2, "output_kw_max": 33.7, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.001, "loss_factor_f1_kwh_per_day": 0.9997, "loss_factor_f2_kwh_per_day": 0.95851, "rejected_factor_f3_per_litre": 0.0, "raw": ["018446", "000035", "0", "2020/Jul/27 17:06", "Bosch Thermotechnology", "Worcester", "Greenstar 8000 Style", "GR8700iW 50 C NG", "47-406-98", "2018", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "33.7", "33.7", "", "", "88.9", "88.2", "", "74.2", "", "2", "", "", "104", "1", "2", "48", "1", "0", "", "", "", "0", "", "", "", "", "2", "7.098", "0.101", "0.001", "0.9997", "12.909", "0.121", "0.001", "0.95851", "0.0", "", "", "", "8325", "", "", "", "", "", "", "", "", "88.8", "98.8", "", "", "", "", "96.9"]} +{"pcdb_id": 18447, "brand_name": "Worcester", "model_name": "Greenstar 8000 Style", "model_qualifier": "GR8700iW 30 CB NG", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 88.2, "comparative_hot_water_efficiency_pct": 73.5, "output_kw_max": 29.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.001, "loss_factor_f1_kwh_per_day": 1.05319, "loss_factor_f2_kwh_per_day": 1.02566, "rejected_factor_f3_per_litre": 0.0, "raw": ["018447", "000035", "0", "2020/Jul/27 17:14", "Bosch Thermotechnology", "Worcester", "Greenstar 8000 Style", "GR8700iW 30 CB NG", "47-406-97", "2018", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "29.5", "29.5", "", "", "88.8", "88.2", "", "73.5", "", "2", "", "", "104", "1", "2", "67", "1", "0", "", "", "", "0", "", "", "", "", "2", "7.168", "0.098", "0.001", "1.05319", "13.007", "0.118", "0.001", "1.02566", "0.0", "", "", "", "8325", "", "", "", "", "", "", "", "", "88.3", "98.7", "", "", "", "", "96.7"]} +{"pcdb_id": 18448, "brand_name": "Worcester", "model_name": "Greenstar 8000 Style", "model_qualifier": "GR8700iW 35 CB NG", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 88.2, "comparative_hot_water_efficiency_pct": 75.1, "output_kw_max": 33.7, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.0045, "loss_factor_f1_kwh_per_day": 0.84809, "loss_factor_f2_kwh_per_day": 0.85555, "rejected_factor_f3_per_litre": 4e-05, "raw": ["018448", "000035", "0", "2020/Jul/27 17:17", "Bosch Thermotechnology", "Worcester", "Greenstar 8000 Style", "GR8700iW 35 CB NG", "47-406-96", "2018", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "33.7", "33.7", "", "", "88.6", "88.2", "", "75.1", "", "2", "", "", "104", "1", "2", "48", "1", "0", "", "", "", "0", "", "", "", "", "2", "7.012", "0.103", "0.0045", "0.84809", "12.813", "0.118", "0.0005", "0.85555", "0.00004", "", "", "", "8325", "", "", "", "", "", "", "", "", "86.9", "98.8", "", "", "", "", "96.6"]} +{"pcdb_id": 18449, "brand_name": "Worcester", "model_name": "Greenstar 8000 Style", "model_qualifier": "GR8700iW 40 CB NG", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 88.2, "comparative_hot_water_efficiency_pct": 73.4, "output_kw_max": 33.7, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.001, "loss_factor_f1_kwh_per_day": 1.03647, "loss_factor_f2_kwh_per_day": 1.03238, "rejected_factor_f3_per_litre": 1e-05, "raw": ["018449", "000035", "0", "2020/Jul/27 17:21", "Bosch Thermotechnology", "Worcester", "Greenstar 8000 Style", "GR8700iW 40 CB NG", "47-406-95", "2018", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "33.7", "33.7", "", "", "88.7", "88.2", "", "73.4", "", "2", "", "", "104", "1", "2", "48", "1", "0", "", "", "", "0", "", "", "", "", "2", "7.175", "0.107", "0.001", "1.03647", "13.05", "0.126", "0.0005", "1.03238", "0.00001", "", "", "", "8325", "", "", "", "", "", "", "", "", "87.4", "98.7", "", "", "", "", "96.6"]} +{"pcdb_id": 18450, "brand_name": "Worcester", "model_name": "Greenstar 8000 Style", "model_qualifier": "GR8700iW 45 CB NG", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 88.2, "comparative_hot_water_efficiency_pct": 74.1, "output_kw_max": 33.7, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.0075, "loss_factor_f1_kwh_per_day": 0.96653, "loss_factor_f2_kwh_per_day": 0.92531, "rejected_factor_f3_per_litre": 4e-05, "raw": ["018450", "000035", "0", "2020/Jul/27 17:25", "Bosch Thermotechnology", "Worcester", "Greenstar 8000 Style", "GR8700iW 45 CB NG", "47-406-94", "2018", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "33.7", "33.7", "", "", "88.9", "88.2", "", "74.1", "", "2", "", "", "104", "1", "2", "48", "1", "0", "", "", "", "0", "", "", "", "", "2", "7.103", "0.104", "0.0075", "0.96653", "12.953", "0.121", "0.0035", "0.92531", "0.00004", "", "", "", "8325", "", "", "", "", "", "", "", "", "88.8", "98.8", "", "", "", "", "96.9"]} +{"pcdb_id": 18451, "brand_name": "Worcester", "model_name": "Greenstar 8000 Style", "model_qualifier": "GR8700iW 50 CB NG", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 88.2, "comparative_hot_water_efficiency_pct": 74.2, "output_kw_max": 33.7, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.001, "loss_factor_f1_kwh_per_day": 0.9997, "loss_factor_f2_kwh_per_day": 0.95851, "rejected_factor_f3_per_litre": 0.0, "raw": ["018451", "000035", "0", "2020/Jul/27 17:30", "Bosch Thermotechnology", "Worcester", "Greenstar 8000 Style", "GR8700iW 50 CB NG", "47-406-93", "2018", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "33.7", "33.7", "", "", "88.9", "88.2", "", "74.2", "", "2", "", "", "104", "1", "2", "48", "1", "0", "", "", "", "0", "", "", "", "", "2", "7.098", "0.101", "0.001", "0.9997", "12.909", "0.121", "0.001", "0.95851", "0.0", "", "", "", "8325", "", "", "", "", "", "", "", "", "88.8", "98.8", "", "", "", "", "96.9"]} +{"pcdb_id": 18452, "brand_name": "Worcester", "model_name": "Greenstar 8000 Style", "model_qualifier": "GR8700iW 30 S NG", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 29.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018452", "000035", "0", "2020/Jan/22 13:03", "Bosch Thermotechnology", "Worcester", "Greenstar 8000 Style", "GR8700iW 30 S NG", "41-406-87", "2018", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "29.5", "29.5", "", "", "88.8", "79.8", "", "58.3", "", "2", "", "", "102", "1", "2", "67", "1", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "8325", "", "", "", "", "", "", "", "", "88.3", "98.7", "", "", "", "", "96.7"]} +{"pcdb_id": 18453, "brand_name": "Worcester", "model_name": "Greenstar 8000 Style", "model_qualifier": "GR8700iW 35 S NG", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 33.7, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018453", "000035", "0", "2019/Aug/21 17:21", "Bosch Thermotechnology", "Worcester", "Greenstar 8000 Style", "GR8700iW 35 S NG", "41-406-86", "2018", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "33.7", "33.7", "", "", "88.6", "79.6", "", "58.2", "", "2", "", "", "102", "1", "2", "48", "1", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "8325", "", "", "", "", "", "", "", "", "86.9", "98.8", "", "", "", "", "96.6"]} +{"pcdb_id": 18454, "brand_name": "Worcester", "model_name": "Greenstar 8000 Style", "model_qualifier": "GR8700iW 30 SB NG", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 29.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018454", "000035", "0", "2020/Apr/08 13:26", "Bosch Thermotechnology", "Worcester", "Greenstar 8000 Style", "GR8700iW 30 SB NG", "41-406-83", "2018", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "29.5", "29.5", "", "", "88.8", "79.8", "", "58.3", "", "2", "", "", "102", "1", "2", "67", "1", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "8325", "", "", "", "", "", "", "", "", "88.3", "98.7", "", "", "", "", "96.7"]} +{"pcdb_id": 18455, "brand_name": "Worcester", "model_name": "Greenstar 8000 Style", "model_qualifier": "GR8700iW 35 SB NG", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 33.7, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018455", "000035", "0", "2019/Aug/22 14:11", "Bosch Thermotechnology", "Worcester", "Greenstar 8000 Style", "GR8700iW 35 SB NG", "41-406-82", "2018", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "33.7", "33.7", "", "", "88.6", "79.6", "", "58.2", "", "2", "", "", "102", "1", "2", "48", "1", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "8325", "", "", "", "", "", "", "", "", "86.9", "98.8", "", "", "", "", "96.6"]} +{"pcdb_id": 18456, "brand_name": "Worcester", "model_name": "Greenstar 8000 Style", "model_qualifier": "GR8700iW 30 C LPG", "winter_efficiency_pct": 90.5, "summer_efficiency_pct": 88.9, "comparative_hot_water_efficiency_pct": 74.1, "output_kw_max": 29.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.008, "loss_factor_f1_kwh_per_day": 1.12085, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018456", "000035", "0", "2020/Jul/16 16:47", "Bosch Thermotechnology", "Worcester", "Greenstar 8000 Style", "GR8700iW 30 C LPG", "47-800-13", "2018", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "29.5", "29.5", "", "", "90.5", "88.9", "", "74.1", "", "2", "0", "", "104", "1", "2", "67", "1", "0", "", "", "", "0", "", "", "", "", "1", "7.261", "0.112", "0.008", "1.12085", "", "", "", "", "", "", "", "", "8325", "", "", "", "", "", "", "", "", "91.0", "99.7", "", "", "", "", "98.1"]} +{"pcdb_id": 18457, "brand_name": "Worcester", "model_name": "Greenstar 8000 Style", "model_qualifier": "GR8700iW 35 C LPG", "winter_efficiency_pct": 90.5, "summer_efficiency_pct": 88.9, "comparative_hot_water_efficiency_pct": 74.9, "output_kw_max": 33.7, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.011, "loss_factor_f1_kwh_per_day": 1.02853, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018457", "000035", "0", "2020/Jul/16 16:50", "Bosch Thermotechnology", "Worcester", "Greenstar 8000 Style", "GR8700iW 35 C LPG", "47-800-12", "2018", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "33.7", "33.7", "", "", "90.5", "88.9", "", "74.9", "", "2", "0", "", "104", "1", "2", "48", "1", "0", "", "", "", "0", "", "", "", "", "1", "7.186", "0.109", "0.011", "1.02853", "", "", "", "", "", "", "", "", "8325", "", "", "", "", "", "", "", "", "90.9", "99.7", "", "", "", "", "98.1"]} +{"pcdb_id": 18458, "brand_name": "Worcester", "model_name": "Greenstar 8000 Style", "model_qualifier": "GR8700iW 40 C LPG", "winter_efficiency_pct": 90.4, "summer_efficiency_pct": 88.9, "comparative_hot_water_efficiency_pct": 73.5, "output_kw_max": 33.7, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.01, "loss_factor_f1_kwh_per_day": 1.16904, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018458", "000035", "0", "2020/Jul/16 17:02", "Bosch Thermotechnology", "Worcester", "Greenstar 8000 Style", "GR8700iW 40 C LPG", "47-800-11", "2018", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "33.7", "33.7", "", "", "90.4", "88.9", "", "73.5", "", "2", "0", "", "104", "1", "2", "48", "1", "0", "", "", "", "0", "", "", "", "", "1", "7.323", "0.112", "0.01", "1.16904", "", "", "", "", "", "", "", "", "8325", "", "", "", "", "", "", "", "", "91.0", "99.6", "", "", "", "", "97.9"]} +{"pcdb_id": 18459, "brand_name": "Worcester", "model_name": "Greenstar 8000 Style", "model_qualifier": "GR8700iW 45 C LPG", "winter_efficiency_pct": 90.7, "summer_efficiency_pct": 89.1, "comparative_hot_water_efficiency_pct": 72.5, "output_kw_max": 33.7, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.002, "loss_factor_f1_kwh_per_day": 1.32645, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018459", "000035", "0", "2020/Jul/16 17:06", "Bosch Thermotechnology", "Worcester", "Greenstar 8000 Style", "GR8700iW 45 C LPG", "47-800-10", "2018", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "33.7", "33.7", "", "", "90.7", "89.1", "", "72.5", "", "2", "0", "", "104", "1", "2", "48", "1", "0", "", "", "", "0", "", "", "", "", "1", "7.425", "0.106", "0.002", "1.32645", "", "", "", "", "", "", "", "", "8325", "", "", "", "", "", "", "", "", "91.5", "100.2", "", "", "", "", "98.5"]} +{"pcdb_id": 18460, "brand_name": "Worcester", "model_name": "Greenstar 8000 Style", "model_qualifier": "GR8700iW 50 C LPG", "winter_efficiency_pct": 90.6, "summer_efficiency_pct": 89.1, "comparative_hot_water_efficiency_pct": 74.5, "output_kw_max": 33.7, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0025, "loss_factor_f1_kwh_per_day": 1.13294, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018460", "000035", "0", "2020/Jul/16 17:17", "Bosch Thermotechnology", "Worcester", "Greenstar 8000 Style", "GR8700iW 50 C LPG", "47-800-09", "2018", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "33.7", "33.7", "", "", "90.6", "89.1", "", "74.5", "", "2", "0", "", "104", "1", "2", "48", "1", "0", "", "", "", "0", "", "", "", "", "1", "7.228", "0.115", "0.0025", "1.13294", "", "", "", "", "", "", "", "", "8325", "", "", "", "", "", "", "", "", "91.5", "99.9", "", "", "", "", "98.3"]} +{"pcdb_id": 18461, "brand_name": "Worcester", "model_name": "Greenstar 8000 Style", "model_qualifier": "GR8700iW 30 S LPG", "winter_efficiency_pct": 90.5, "summer_efficiency_pct": 81.5, "comparative_hot_water_efficiency_pct": 59.5, "output_kw_max": 29.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018461", "000035", "0", "2020/Apr/15 11:15", "Bosch Thermotechnology", "Worcester", "Greenstar 8000 Style", "GR8700iW 30 S LPG", "41-406-89", "2018", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "29.5", "29.5", "", "", "90.5", "81.5", "", "59.5", "", "2", "0", "", "102", "1", "2", "67", "1", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "8325", "", "", "", "", "", "", "", "", "91.0", "99.7", "", "", "", "", "98.1"]} +{"pcdb_id": 18462, "brand_name": "Worcester", "model_name": "Greenstar 8000 Style", "model_qualifier": "GR8700iW 35 S LPG", "winter_efficiency_pct": 90.5, "summer_efficiency_pct": 81.5, "comparative_hot_water_efficiency_pct": 59.5, "output_kw_max": 33.7, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018462", "000035", "0", "2020/Apr/15 11:16", "Bosch Thermotechnology", "Worcester", "Greenstar 8000 Style", "GR8700iW 35 S LPG", "41-406-88", "2018", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "33.7", "33.7", "", "", "90.5", "81.5", "", "59.5", "", "2", "0", "", "102", "1", "2", "48", "1", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "8325", "", "", "", "", "", "", "", "", "90.9", "99.7", "", "", "", "", "98.1"]} +{"pcdb_id": 18463, "brand_name": "Worcester", "model_name": "Greenstar 8000 Style", "model_qualifier": "GR8700iW 30 CB LPG", "winter_efficiency_pct": 90.5, "summer_efficiency_pct": 88.9, "comparative_hot_water_efficiency_pct": 74.1, "output_kw_max": 29.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.008, "loss_factor_f1_kwh_per_day": 1.12085, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018463", "000035", "0", "2020/Jul/16 17:31", "Bosch Thermotechnology", "Worcester", "Greenstar 8000 Style", "GR8700iW 30 CB LPG", "47-800-08", "2018", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "29.5", "29.5", "", "", "90.5", "88.9", "", "74.1", "", "2", "0", "", "104", "1", "2", "67", "1", "0", "", "", "", "0", "", "", "", "", "1", "7.261", "0.112", "0.008", "1.12085", "", "", "", "", "", "", "", "", "8325", "", "", "", "", "", "", "", "", "91.0", "99.7", "", "", "", "", "98.1"]} +{"pcdb_id": 18464, "brand_name": "Worcester", "model_name": "Greenstar 8000 Style", "model_qualifier": "GR8700iW 35 CB LPG", "winter_efficiency_pct": 90.5, "summer_efficiency_pct": 88.9, "comparative_hot_water_efficiency_pct": 74.9, "output_kw_max": 33.7, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.011, "loss_factor_f1_kwh_per_day": 1.02853, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018464", "000035", "0", "2020/Jul/16 17:35", "Bosch Thermotechnology", "Worcester", "Greenstar 8000 Style", "GR8700iW 35 CB LPG", "47-800-07", "2018", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "33.7", "33.7", "", "", "90.5", "88.9", "", "74.9", "", "2", "0", "", "104", "1", "2", "48", "1", "0", "", "", "", "0", "", "", "", "", "1", "7.186", "0.109", "0.011", "1.02853", "", "", "", "", "", "", "", "", "8325", "", "", "", "", "", "", "", "", "90.9", "99.7", "", "", "", "", "98.1"]} +{"pcdb_id": 18465, "brand_name": "Worcester", "model_name": "Greenstar 8000 Style", "model_qualifier": "GR8700iW 40 CB LPG", "winter_efficiency_pct": 90.4, "summer_efficiency_pct": 88.9, "comparative_hot_water_efficiency_pct": 73.5, "output_kw_max": 33.7, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.01, "loss_factor_f1_kwh_per_day": 1.16904, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018465", "000035", "0", "2020/Jul/16 17:42", "Bosch Thermotechnology", "Worcester", "Greenstar 8000 Style", "GR8700iW 40 CB LPG", "47-800-06", "2018", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "33.7", "33.7", "", "", "90.4", "88.9", "", "73.5", "", "2", "0", "", "104", "1", "2", "48", "1", "0", "", "", "", "0", "", "", "", "", "1", "7.323", "0.112", "0.01", "1.16904", "", "", "", "", "", "", "", "", "8325", "", "", "", "", "", "", "", "", "91.0", "99.6", "", "", "", "", "97.9"]} +{"pcdb_id": 18466, "brand_name": "Worcester", "model_name": "Greenstar 8000 Style", "model_qualifier": "GR8700iW 45 CB LPG", "winter_efficiency_pct": 90.7, "summer_efficiency_pct": 89.1, "comparative_hot_water_efficiency_pct": 72.5, "output_kw_max": 33.7, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.002, "loss_factor_f1_kwh_per_day": 1.32645, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018466", "000035", "0", "2020/Jul/16 17:46", "Bosch Thermotechnology", "Worcester", "Greenstar 8000 Style", "GR8700iW 45 CB LPG", "47-800-05", "2018", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "33.7", "33.7", "", "", "90.7", "89.1", "", "72.5", "", "2", "0", "", "104", "1", "2", "48", "1", "0", "", "", "", "0", "", "", "", "", "1", "7.425", "0.106", "0.002", "1.32645", "", "", "", "", "", "", "", "", "8325", "", "", "", "", "", "", "", "", "91.5", "100.2", "", "", "", "", "98.5"]} +{"pcdb_id": 18467, "brand_name": "Worcester", "model_name": "Greenstar 8000 Style", "model_qualifier": "GR8700iW 50 CB LPG", "winter_efficiency_pct": 90.6, "summer_efficiency_pct": 89.1, "comparative_hot_water_efficiency_pct": 74.5, "output_kw_max": 33.7, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0025, "loss_factor_f1_kwh_per_day": 1.13294, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018467", "000035", "0", "2020/Jul/16 17:47", "Bosch Thermotechnology", "Worcester", "Greenstar 8000 Style", "GR8700iW 50 CB LPG", "47-800-04", "2018", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "33.7", "33.7", "", "", "90.6", "89.1", "", "74.5", "", "2", "0", "", "104", "1", "2", "48", "1", "0", "", "", "", "0", "", "", "", "", "1", "7.228", "0.115", "0.0025", "1.13294", "", "", "", "", "", "", "", "", "8325", "", "", "", "", "", "", "", "", "91.5", "99.9", "", "", "", "", "98.3"]} +{"pcdb_id": 18468, "brand_name": "Worcester", "model_name": "Greenstar 8000 Style", "model_qualifier": "GR8700iW 30 SB LPG", "winter_efficiency_pct": 90.5, "summer_efficiency_pct": 81.5, "comparative_hot_water_efficiency_pct": 59.5, "output_kw_max": 29.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018468", "000035", "0", "2020/Apr/15 11:17", "Bosch Thermotechnology", "Worcester", "Greenstar 8000 Style", "GR8700iW 30 SB LPG", "41-406-85", "2018", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "29.5", "29.5", "", "", "90.5", "81.5", "", "59.5", "", "2", "0", "", "102", "1", "2", "67", "1", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "8325", "", "", "", "", "", "", "", "", "91.0", "99.7", "", "", "", "", "98.1"]} +{"pcdb_id": 18469, "brand_name": "Worcester", "model_name": "Greenstar 8000 Style", "model_qualifier": "GR8700iW 35 SB LPG", "winter_efficiency_pct": 90.5, "summer_efficiency_pct": 81.5, "comparative_hot_water_efficiency_pct": 59.5, "output_kw_max": 33.7, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018469", "000035", "0", "2020/Apr/15 11:17", "Bosch Thermotechnology", "Worcester", "Greenstar 8000 Style", "GR8700iW 35 SB LPG", "41-406-84", "2018", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "33.7", "33.7", "", "", "90.5", "81.5", "", "59.5", "", "2", "0", "", "102", "1", "2", "48", "1", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "8325", "", "", "", "", "", "", "", "", "90.9", "99.7", "", "", "", "", "98.1"]} +{"pcdb_id": 18470, "brand_name": "Ravenheat", "model_name": "HE 30 S Compact", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 55.9, "output_kw_max": 24.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018470", "000026", "0", "2018/Oct/22 11:03", "Ravenheat Manufacturing", "Ravenheat", "HE 30 S Compact", "", "", "2018", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.3", "24.3", "", "", "88.0", "79.4", "", "55.9", "", "2", "", "", "104", "1", "2", "34", "5", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.5", "97.1", "", "", "", "", "95.3"]} +{"pcdb_id": 18471, "brand_name": "Ravenheat", "model_name": "HE 98 S", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 55.9, "output_kw_max": 24.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018471", "000026", "0", "2018/Oct/22 11:03", "Ravenheat Manufacturing", "Ravenheat", "HE 98 S", "", "", "2017", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.3", "24.3", "", "", "88.0", "79.4", "", "55.9", "", "2", "", "", "104", "1", "2", "34", "5", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.5", "97.1", "", "", "", "", "95.3"]} +{"pcdb_id": 18472, "brand_name": "Firebird", "model_name": "Envirogreen Heatpac Condensing Boiler", "model_qualifier": "12-20kW", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 81.4, "comparative_hot_water_efficiency_pct": 59.5, "output_kw_max": 20.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018472", "000047", "0", "2018/Sep/05 10:28", "Firebird Heating Solutions Ltd", "Firebird", "Envirogreen Heatpac Condensing Boiler", "12-20kW", "", "2018", "current", "4", "1", "2", "1", "0", "", "", "2", "2", "1", "12.0", "20.0", "", "", "89.2", "81.4", "", "59.5", "", "2", "", "", "201", "1", "1", "178", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "92.8", "97.1", "", "", "", "", "96.3"]} +{"pcdb_id": 18473, "brand_name": "Firebird", "model_name": "Envirogreen Heatpac Condensing Boiler", "model_qualifier": "20-26kW", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 81.2, "comparative_hot_water_efficiency_pct": 59.3, "output_kw_max": 26.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018473", "000047", "0", "2018/Sep/05 10:29", "Firebird Heating Solutions Ltd", "Firebird", "Envirogreen Heatpac Condensing Boiler", "20-26kW", "", "2018", "current", "4", "1", "2", "1", "0", "", "", "2", "2", "1", "20", "26", "", "", "89.0", "81.2", "", "59.3", "", "2", "", "", "201", "1", "1", "184", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "92.7", "96.6", "", "", "", "", "95.9"]} +{"pcdb_id": 18474, "brand_name": "Firebird", "model_name": "Envirogreen Heatpac Condensing Boiler", "model_qualifier": "35kW", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 80.9, "comparative_hot_water_efficiency_pct": 59.1, "output_kw_max": 35.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018474", "000047", "0", "2018/Sep/05 10:29", "Firebird Heating Solutions Ltd", "Firebird", "Envirogreen Heatpac Condensing Boiler", "35kW", "", "2018", "current", "4", "1", "2", "1", "0", "", "", "2", "2", "1", "26.0", "35.0", "", "", "88.7", "80.9", "", "59.1", "", "2", "", "", "201", "1", "1", "165", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "92.0", "96.1", "", "", "", "", "95.4"]} +{"pcdb_id": 18475, "brand_name": "Firebird", "model_name": "Envirogreen Kitchen Condensing Boiler", "model_qualifier": "12-20kW", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 81.4, "comparative_hot_water_efficiency_pct": 59.5, "output_kw_max": 20.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018475", "000047", "0", "2018/Sep/05 10:29", "Firebird Heating Solutions Ltd", "Firebird", "Envirogreen Kitchen Condensing Boiler", "12-20kW", "", "2018", "current", "4", "1", "1", "1", "0", "", "", "2", "2", "1", "12.0", "20.0", "", "", "89.2", "81.4", "", "59.5", "", "2", "", "", "201", "1", "1", "178", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "92.8", "97.1", "", "", "", "", "96.3"]} +{"pcdb_id": 18476, "brand_name": "Firebird", "model_name": "Envirogreen Kitchen Condensing Boiler", "model_qualifier": "20-26kW", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 81.2, "comparative_hot_water_efficiency_pct": 59.3, "output_kw_max": 26.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018476", "000047", "0", "2018/Sep/05 10:29", "Firebird Heating Solutions Ltd", "Firebird", "Envirogreen Kitchen Condensing Boiler", "20-26kW", "", "2018", "current", "4", "1", "1", "1", "0", "", "", "2", "2", "1", "20.0", "26.0", "", "", "89.0", "81.2", "", "59.3", "", "2", "", "", "201", "1", "1", "184", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "92.7", "96.6", "", "", "", "", "95.9"]} +{"pcdb_id": 18477, "brand_name": "Firebird", "model_name": "Envirogreen Kitchen Condensing Boiler", "model_qualifier": "35kW", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 80.9, "comparative_hot_water_efficiency_pct": 59.1, "output_kw_max": 35.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018477", "000047", "0", "2018/Sep/05 10:30", "Firebird Heating Solutions Ltd", "Firebird", "Envirogreen Kitchen Condensing Boiler", "35kW", "", "2018", "current", "4", "1", "1", "1", "0", "", "", "2", "2", "1", "26.0", "35.0", "", "", "88.7", "80.9", "", "59.1", "", "2", "", "", "201", "1", "1", "165", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "92.0", "96.1", "", "", "", "", "95.4"]} +{"pcdb_id": 18478, "brand_name": "Firebird", "model_name": "Envirogreen Popular Condensing Boiler", "model_qualifier": "12-20kW", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 81.4, "comparative_hot_water_efficiency_pct": 59.5, "output_kw_max": 20.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018478", "000047", "0", "2018/Sep/05 10:30", "Firebird Heating Solutions Ltd", "Firebird", "Envirogreen Popular Condensing Boiler", "12-20kW", "", "2018", "current", "4", "1", "1", "1", "0", "", "", "2", "2", "1", "12.0", "20.0", "", "", "89.2", "81.4", "", "59.5", "", "2", "", "", "201", "1", "1", "178", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "92.8", "97.1", "", "", "", "", "96.3"]} +{"pcdb_id": 18479, "brand_name": "Firebird", "model_name": "Envirogreen Popular Condensing Boiler", "model_qualifier": "20-26kW", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 81.2, "comparative_hot_water_efficiency_pct": 59.3, "output_kw_max": 26.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018479", "000047", "0", "2018/Sep/05 10:30", "Firebird Heating Solutions Ltd", "Firebird", "Envirogreen Popular Condensing Boiler", "20-26kW", "", "2018", "current", "4", "1", "1", "1", "0", "", "", "2", "2", "1", "20.0", "26.0", "", "", "89.0", "81.2", "", "59.3", "", "2", "", "", "201", "1", "1", "184", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "92.7", "96.6", "", "", "", "", "95.9"]} +{"pcdb_id": 18480, "brand_name": "Firebird", "model_name": "Envirogreen Popular Condensing Boiler", "model_qualifier": "35kW", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 80.9, "comparative_hot_water_efficiency_pct": 59.1, "output_kw_max": 35.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018480", "000047", "0", "2018/Sep/05 10:31", "Firebird Heating Solutions Ltd", "Firebird", "Envirogreen Popular Condensing Boiler", "35kW", "", "2018", "current", "4", "1", "1", "1", "0", "", "", "2", "2", "1", "26.0", "35.0", "", "", "88.7", "80.9", "", "59.1", "", "2", "", "", "201", "1", "1", "165", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "92.0", "96.1", "", "", "", "", "95.4"]} +{"pcdb_id": 18481, "brand_name": "Firebird", "model_name": "Envirogreen Slimline Heatpac Condensing", "model_qualifier": "12-20kW", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 81.4, "comparative_hot_water_efficiency_pct": 59.5, "output_kw_max": 20.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018481", "000047", "0", "2018/Sep/05 10:31", "Firebird Heating Solutions Ltd", "Firebird", "Envirogreen Slimline Heatpac Condensing", "12-20kW", "", "2018", "current", "4", "1", "2", "1", "0", "", "", "2", "2", "1", "12.0", "20.0", "", "", "89.2", "81.4", "", "59.5", "", "2", "", "", "201", "1", "1", "178", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "92.8", "97.1", "", "", "", "", "96.3"]} +{"pcdb_id": 18482, "brand_name": "Firebird", "model_name": "Envirogreen Slimline Heatpac Condensing", "model_qualifier": "20-26", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 81.2, "comparative_hot_water_efficiency_pct": 59.3, "output_kw_max": 26.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018482", "000047", "0", "2018/Sep/05 10:31", "Firebird Heating Solutions Ltd", "Firebird", "Envirogreen Slimline Heatpac Condensing", "20-26", "", "2018", "current", "4", "1", "2", "1", "0", "", "", "2", "2", "1", "20.0", "26.0", "", "", "89.0", "81.2", "", "59.3", "", "2", "", "", "201", "1", "1", "184", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "92.7", "96.6", "", "", "", "", "95.9"]} +{"pcdb_id": 18483, "brand_name": "Firebird", "model_name": "Envirogreen Slimline Heatpac Condensing", "model_qualifier": "35kW", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 80.9, "comparative_hot_water_efficiency_pct": 59.1, "output_kw_max": 35.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018483", "000047", "0", "2018/Sep/05 10:31", "Firebird Heating Solutions Ltd", "Firebird", "Envirogreen Slimline Heatpac Condensing", "35kW", "", "2018", "current", "4", "1", "2", "1", "0", "", "", "2", "2", "1", "26.0", "35.0", "", "", "88.7", "80.9", "", "59.1", "", "2", "", "", "201", "1", "1", "165", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "92.0", "96.1", "", "", "", "", "95.4"]} +{"pcdb_id": 18484, "brand_name": "Alpha", "model_name": "E-Tec PLUS", "model_qualifier": "28", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 88.2, "comparative_hot_water_efficiency_pct": 75.2, "output_kw_max": 24.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.0055, "loss_factor_f1_kwh_per_day": 0.86242, "loss_factor_f2_kwh_per_day": 0.84011, "rejected_factor_f3_per_litre": 1e-05, "raw": ["018484", "000001", "0", "2020/Apr/09 16:35", "Alpha Therm", "Alpha", "E-Tec PLUS", "28", "3.028466", "2018", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.0", "24.0", "", "", "88.3", "88.2", "", "75.2", "", "2", "", "", "104", "1", "2", "10", "2", "0", "", "", "", "0", "", "", "", "", "2", "7.002", "0.082", "0.0055", "0.86242", "12.57", "0.112", "0.0045", "0.84011", "0.00001", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.1", "97.6", "", "", "", "", "95.8"]} +{"pcdb_id": 18486, "brand_name": "Alpha", "model_name": "E-Tec PLUS", "model_qualifier": "33", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 88.2, "comparative_hot_water_efficiency_pct": 74.7, "output_kw_max": 28.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.0085, "loss_factor_f1_kwh_per_day": 0.89436, "loss_factor_f2_kwh_per_day": 0.86958, "rejected_factor_f3_per_litre": 5e-05, "raw": ["018486", "000001", "0", "2020/Apr/09 16:34", "Alpha Therm", "Alpha", "E-Tec PLUS", "33", "3.028467", "2017", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28.0", "28.0", "", "", "88.4", "88.2", "", "74.7", "", "2", "", "", "104", "1", "2", "12", "2", "0", "", "", "", "0", "", "", "", "", "2", "7.051", "0.095", "0.0085", "0.89436", "12.849", "0.125", "0.004", "0.86958", "0.00005", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.2", "97.7", "", "", "", "", "95.9"]} +{"pcdb_id": 18487, "brand_name": "Alpha", "model_name": "E-Tec PLUS", "model_qualifier": "33 LPG", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 90.3, "comparative_hot_water_efficiency_pct": 77.1, "output_kw_max": 28.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.0045, "loss_factor_f1_kwh_per_day": 0.84841, "loss_factor_f2_kwh_per_day": 0.83445, "rejected_factor_f3_per_litre": 1e-05, "raw": ["018487", "000001", "0", "2020/Apr/09 16:30", "Alpha Therm", "Alpha", "E-Tec PLUS", "33 LPG", "3.028467GPL", "2018", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "28.0", "28.0", "", "", "89.4", "90.3", "", "77.1", "", "2", "1", "", "104", "1", "2", "12", "2", "0", "", "", "", "0", "", "", "", "", "2", "6.979", "0.096", "0.0045", "0.84841", "12.541", "0.117", "0.004", "0.83445", "0.00001", "", "", "", "1005", "", "", "", "", "", "", "", "", "90.2", "99.8", "", "", "", "", "98.0"]} +{"pcdb_id": 18489, "brand_name": "Alpha", "model_name": "E-Tec", "model_qualifier": "30S", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 28.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018489", "000001", "0", "2019/Apr/26 09:20", "Alpha Therm", "Alpha", "E-Tec", "30S", "3.028470", "2018", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "28.0", "28.0", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "12", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.2", "97.7", "", "", "", "", "95.9"]} +{"pcdb_id": 18490, "brand_name": "Alpha", "model_name": "E-Tec", "model_qualifier": "30S LPG", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 80.4, "comparative_hot_water_efficiency_pct": 58.7, "output_kw_max": 28.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018490", "000001", "0", "2019/Sep/11 10:49", "Alpha Therm", "Alpha", "E-Tec", "30S LPG", "3.028470GPL", "2018", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "28.0", "28.0", "", "", "89.4", "80.4", "", "58.7", "", "2", "1", "", "102", "1", "2", "12", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "1005", "", "", "", "", "", "", "", "", "90.2", "99.8", "", "", "", "", "98.0"]} +{"pcdb_id": 18491, "brand_name": "Alpha", "model_name": "E-Tec", "model_qualifier": "20S", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 24.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018491", "000001", "0", "2019/Apr/26 09:21", "Alpha Therm", "Alpha", "E-Tec", "20S", "3.028469", "2018", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24.0", "24.0", "", "", "88.3", "79.3", "", "57.9", "", "2", "", "", "102", "1", "2", "10", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.1", "97.6", "", "", "", "", "95.8"]} +{"pcdb_id": 18492, "brand_name": "Baxi", "model_name": "636 COMBI", "model_qualifier": "36", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 86.7, "comparative_hot_water_efficiency_pct": 81.4, "output_kw_max": 25.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0015, "loss_factor_f1_kwh_per_day": 0.37471, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018492", "000005", "0", "2020/Jan/22 13:05", "Baxi Heating UK", "Baxi", "636 COMBI", "36", "47-077-30", "2018", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "25.0", "25.0", "", "", "88.4", "86.7", "", "81.4", "", "2", "", "", "104", "1", "2", "112", "3", "0", "", "", "", "0", "", "", "", "", "1", "6.471", "0.102", "0.0015", "0.37471", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "88.1", "97.8", "", "", "", "", "96.0"]} +{"pcdb_id": 18493, "brand_name": "Potterton", "model_name": "ASSURE", "model_qualifier": "36 COMBI", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 86.7, "comparative_hot_water_efficiency_pct": 81.4, "output_kw_max": 25.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0015, "loss_factor_f1_kwh_per_day": 0.37471, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018493", "000005", "0", "2020/Jan/22 13:05", "Baxi Heating UK", "Potterton", "ASSURE", "36 COMBI", "47-393-67", "2018", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "25.0", "25.0", "", "", "88.4", "86.7", "", "81.4", "", "2", "", "", "104", "1", "2", "112", "3", "0", "", "", "", "0", "", "", "", "", "1", "6.471", "0.102", "0.0015", "0.37471", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "88.1", "97.8", "", "", "", "", "96.0"]} +{"pcdb_id": 18495, "brand_name": "Ideal", "model_name": "LOGIC MAX COMBI", "model_qualifier": "C24P", "winter_efficiency_pct": 90.1, "summer_efficiency_pct": 81.5, "comparative_hot_water_efficiency_pct": 57.3, "output_kw_max": 24.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018495", "000008", "0", "2021/Jan/07 16:05", "Ideal Boilers", "Ideal", "LOGIC MAX COMBI", "C24P", "47-349-55", "2018", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24.0", "24.0", "", "", "90.1", "81.5", "", "57.3", "", "2", "1", "", "104", "1", "2", "42", "5", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "", "", "", "", "92.0", "100.8", "", "", "", "", "99.1"]} +{"pcdb_id": 18496, "brand_name": "Ideal", "model_name": "LOGIC MAX COMBI", "model_qualifier": "C30", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 70.4, "output_kw_max": 30.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0025, "loss_factor_f1_kwh_per_day": 1.38753, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018496", "000008", "0", "2021/Jan/08 17:35", "Ideal Boilers", "Ideal", "LOGIC MAX COMBI", "C30", "47-349-57", "2018", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "30.0", "30.0", "", "", "89.0", "87.3", "", "70.4", "", "2", "", "", "104", "1", "2", "32", "5", "0", "", "", "", "0", "", "", "", "", "1", "7.476", "0.075", "0.0025", "1.38753", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "", "", "", "", "90.0", "98.6", "", "", "", "", "96.9"]} +{"pcdb_id": 18497, "brand_name": "Ideal", "model_name": "LOGIC MAX COMBI", "model_qualifier": "C30P", "winter_efficiency_pct": 90.1, "summer_efficiency_pct": 81.5, "comparative_hot_water_efficiency_pct": 57.3, "output_kw_max": 30.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018497", "000008", "0", "2019/Oct/21 13:02", "Ideal Boilers", "Ideal", "LOGIC MAX COMBI", "C30P", "47-349-75", "2018", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "30.0", "30.0", "", "", "90.1", "81.5", "", "57.3", "", "2", "1", "", "104", "1", "2", "32", "5", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "", "", "", "", "92.0", "100.8", "", "", "", "", "99.1"]} +{"pcdb_id": 18498, "brand_name": "Ideal", "model_name": "LOGIC MAX COMBI", "model_qualifier": "C35", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 71.1, "output_kw_max": 35.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0025, "loss_factor_f1_kwh_per_day": 1.32452, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018498", "000008", "0", "2020/Jan/22 13:07", "Ideal Boilers", "Ideal", "LOGIC MAX COMBI", "C35", "47-349-58", "2018", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "35.0", "35.0", "", "", "89.0", "87.3", "", "71.1", "", "2", "", "", "104", "1", "2", "29", "5", "0", "", "", "", "0", "", "", "", "", "1", "7.411", "0.074", "0.0025", "1.32452", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "", "", "", "", "90.0", "98.6", "", "", "", "", "96.9"]} +{"pcdb_id": 18499, "brand_name": "Ideal", "model_name": "LOGIC MAX HEAT", "model_qualifier": "H12", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 12.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018499", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "LOGIC MAX HEAT", "H12", "41-796-17", "2018", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "12.0", "12.0", "", "", "88.8", "79.8", "", "58.3", "", "2", "", "", "102", "1", "2", "20", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "90.0", "97.9", "", "", "", "", "96.4"]} +{"pcdb_id": 18500, "brand_name": "Ideal", "model_name": "LOGIC MAX HEAT", "model_qualifier": "H15", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 15.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018500", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "LOGIC MAX HEAT", "H15", "41-796-18", "2018", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "15.0", "15.0", "", "", "88.7", "79.7", "", "58.2", "", "2", "", "", "102", "1", "2", "21", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "90.0", "97.8", "", "", "", "", "96.4"]} +{"pcdb_id": 18501, "brand_name": "Ideal", "model_name": "LOGIC MAX HEAT", "model_qualifier": "H18", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 18.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018501", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "LOGIC MAX HEAT", "H18", "41-796-19", "2018", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18.0", "18.0", "", "", "89.0", "80.0", "", "58.4", "", "2", "", "", "102", "1", "2", "26", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "90.0", "98.5", "", "", "", "", "96.9"]} +{"pcdb_id": 18502, "brand_name": "Ideal", "model_name": "LOGIC MAX HEAT", "model_qualifier": "H24", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 24.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018502", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "LOGIC MAX HEAT", "H24", "41-796-20", "2018", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24.0", "24.0", "", "", "89.0", "80.0", "", "58.5", "", "2", "", "", "102", "1", "2", "42", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "90.0", "98.6", "", "", "", "", "96.9"]} +{"pcdb_id": 18503, "brand_name": "Ideal", "model_name": "LOGIC MAX HEAT", "model_qualifier": "H24P", "winter_efficiency_pct": 90.1, "summer_efficiency_pct": 81.1, "comparative_hot_water_efficiency_pct": 59.2, "output_kw_max": 24.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018503", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "LOGIC MAX HEAT", "H24P", "41-796-20", "2018", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "24.0", "24.0", "", "", "90.1", "81.1", "", "59.2", "", "2", "1", "", "102", "1", "2", "42", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "92.0", "100.8", "", "", "", "", "99.1"]} +{"pcdb_id": 18504, "brand_name": "Ideal", "model_name": "LOGIC MAX HEAT", "model_qualifier": "H30", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 30.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018504", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "LOGIC MAX HEAT", "H30", "41-796-21", "2018", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "30.0", "30.0", "", "", "88.8", "79.8", "", "58.3", "", "2", "", "", "102", "1", "2", "48", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "89.6", "98.2", "", "", "", "", "96.6"]} +{"pcdb_id": 18505, "brand_name": "Ideal", "model_name": "LOGIC MAX HEAT", "model_qualifier": "H30P", "winter_efficiency_pct": 89.8, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 59.1, "output_kw_max": 30.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018505", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "LOGIC MAX HEAT", "H30P", "41-796-21", "2018", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "30.0", "30.0", "", "", "89.8", "80.8", "", "59.1", "", "2", "1", "", "102", "1", "2", "48", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "91.6", "100.4", "", "", "", "", "98.7"]} +{"pcdb_id": 18506, "brand_name": "Ideal", "model_name": "LOGIC MAX SYSTEM", "model_qualifier": "S15", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 15.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018506", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "LOGIC MAX SYSTEM", "S15", "41-796-13", "2018", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "15.0", "15.0", "", "", "88.7", "79.7", "", "58.2", "", "2", "", "", "102", "1", "2", "21", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "90.0", "97.8", "", "", "", "", "96.4"]} +{"pcdb_id": 18507, "brand_name": "Ideal", "model_name": "LOGIC MAX SYSTEM", "model_qualifier": "S18", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 18.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018507", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "LOGIC MAX SYSTEM", "S18", "41-796-14", "2018", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18.0", "18.0", "", "", "89.0", "80.0", "", "58.4", "", "2", "", "", "102", "1", "2", "26", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "89.8", "98.5", "", "", "", "", "96.8"]} +{"pcdb_id": 18508, "brand_name": "Ideal", "model_name": "LOGIC MAX SYSTEM", "model_qualifier": "S24", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 24.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018508", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "LOGIC MAX SYSTEM", "S24", "41-796-15", "2018", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24.0", "24.0", "", "", "89.0", "80.0", "", "58.5", "", "2", "", "", "102", "1", "2", "42", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "90.0", "98.6", "", "", "", "", "96.9"]} +{"pcdb_id": 18509, "brand_name": "Ideal", "model_name": "LOGIC MAX SYSTEM", "model_qualifier": "S30", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 30.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018509", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "LOGIC MAX SYSTEM", "S30", "41-796-16", "2018", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "30.0", "30.0", "", "", "88.8", "79.8", "", "58.3", "", "2", "", "", "102", "1", "2", "48", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "89.6", "98.2", "", "", "", "", "96.6"]} +{"pcdb_id": 18510, "brand_name": "Ideal", "model_name": "LOGIC MAX SYSTEM", "model_qualifier": "S30P", "winter_efficiency_pct": 89.8, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 59.1, "output_kw_max": 30.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018510", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "LOGIC MAX SYSTEM", "S30P", "41-796-16", "2018", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "30.0", "30.0", "", "", "89.8", "80.8", "", "59.1", "", "2", "1", "", "102", "1", "2", "48", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "91.6", "100.4", "", "", "", "", "98.7"]} +{"pcdb_id": 18511, "brand_name": "Ideal", "model_name": "LOGIC MAX COMBI", "model_qualifier": "C24", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 69.8, "output_kw_max": 24.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0025, "loss_factor_f1_kwh_per_day": 1.4583, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018511", "000008", "0", "2021/Jan/08 17:40", "Ideal Boilers", "Ideal", "LOGIC MAX COMBI", "C24", "47-349-56", "2018", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.0", "24.0", "", "", "89.0", "87.3", "", "69.8", "", "2", "", "", "104", "1", "2", "42", "5", "0", "", "", "", "0", "", "", "", "", "1", "7.549", "0.076", "0.0025", "1.4583", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "", "", "", "", "90.0", "98.6", "", "", "", "", "96.9"]} +{"pcdb_id": 18512, "brand_name": "Ideal", "model_name": "VOGUE MAX COMBI", "model_qualifier": "26", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 76.2, "output_kw_max": 26.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.001, "loss_factor_f1_kwh_per_day": 0.84569, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018512", "000008", "0", "2021/Jan/08 17:45", "Ideal Boilers", "Ideal", "VOGUE MAX COMBI", "26", "47-349-59", "2018", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "26.0", "26.0", "", "", "88.6", "87.3", "", "76.2", "", "2", "", "", "104", "1", "2", "47", "3", "0", "", "", "", "0", "", "", "", "", "1", "6.915", "0.085", "0.001", "0.84569", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "", "", "", "", "89.7", "97.7", "", "", "", "", "96.2"]} +{"pcdb_id": 18513, "brand_name": "Ideal", "model_name": "VOGUE MAX COMBI", "model_qualifier": "26P", "winter_efficiency_pct": 89.6, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 57.0, "output_kw_max": 26.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018513", "000008", "0", "2019/Oct/21 13:27", "Ideal Boilers", "Ideal", "VOGUE MAX COMBI", "26P", "47-349-59", "2018", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "26.0", "26.0", "", "", "89.6", "81.0", "", "57.0", "", "2", "1", "", "104", "1", "2", "47", "3", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "", "", "", "", "91.7", "99.8", "", "", "", "", "98.3"]} +{"pcdb_id": 18514, "brand_name": "Ideal", "model_name": "VOGUE MAX COMBI", "model_qualifier": "32", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 77.6, "output_kw_max": 32.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.001, "loss_factor_f1_kwh_per_day": 0.72908, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018514", "000008", "0", "2021/Jan/08 17:49", "Ideal Boilers", "Ideal", "VOGUE MAX COMBI", "32", "47-349-60", "2018", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "32.0", "32.0", "", "", "88.7", "87.3", "", "77.6", "", "2", "", "", "104", "1", "2", "63", "3", "0", "", "", "", "0", "", "", "", "", "1", "6.79", "0.087", "0.001", "0.72908", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "", "", "", "", "89.9", "97.8", "", "", "", "", "96.3"]} +{"pcdb_id": 18515, "brand_name": "Ideal", "model_name": "VOGUE MAX COMBI", "model_qualifier": "32P", "winter_efficiency_pct": 89.7, "summer_efficiency_pct": 81.1, "comparative_hot_water_efficiency_pct": 57.1, "output_kw_max": 32.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018515", "000008", "0", "2019/Oct/21 13:30", "Ideal Boilers", "Ideal", "VOGUE MAX COMBI", "32P", "47-349-60", "2018", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "32.0", "32.0", "", "", "89.7", "81.1", "", "57.1", "", "2", "1", "", "104", "1", "2", "63", "3", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "", "", "", "", "91.9", "100.0", "", "", "", "", "98.5"]} +{"pcdb_id": 18516, "brand_name": "Ideal", "model_name": "VOGUE MAX COMBI", "model_qualifier": "40", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 77.2, "output_kw_max": 40.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.001, "loss_factor_f1_kwh_per_day": 0.75466, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018516", "000008", "0", "2021/Jan/08 17:51", "Ideal Boilers", "Ideal", "VOGUE MAX COMBI", "40", "47-349-61", "2018", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "40.0", "40.0", "", "", "88.6", "87.3", "", "77.2", "", "2", "", "", "104", "1", "2", "44", "3", "0", "", "", "", "0", "", "", "", "", "1", "6.821", "0.086", "0.001", "0.75466", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "", "", "", "", "89.7", "97.5", "", "", "", "", "96.0"]} +{"pcdb_id": 18517, "brand_name": "Ideal", "model_name": "VOGUE MAX COMBI", "model_qualifier": "40P", "winter_efficiency_pct": 89.6, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 56.9, "output_kw_max": 40.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018517", "000008", "0", "2019/Oct/21 13:33", "Ideal Boilers", "Ideal", "VOGUE MAX COMBI", "40P", "47-349-61", "2018", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "40.0", "40.0", "", "", "89.6", "81.0", "", "56.9", "", "2", "1", "", "104", "1", "2", "44", "3", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "", "", "", "", "91.7", "99.7", "", "", "", "", "98.1"]} +{"pcdb_id": 18518, "brand_name": "Ideal", "model_name": "VOGUE MAX SYSTEM", "model_qualifier": "15", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 15.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018518", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "VOGUE MAX SYSTEM", "15", "41-796-22", "2018", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "15.0", "15.0", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "25", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "89.6", "97.0", "", "", "", "", "95.6"]} +{"pcdb_id": 18519, "brand_name": "Ideal", "model_name": "VOGUE MAX SYSTEM", "model_qualifier": "15P", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 80.4, "comparative_hot_water_efficiency_pct": 58.7, "output_kw_max": 15.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018519", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "VOGUE MAX SYSTEM", "15P", "41-796-22", "2018", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "15.0", "15.0", "", "", "89.4", "80.4", "", "58.7", "", "2", "1", "", "102", "1", "2", "25", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "91.5", "99.2", "", "", "", "", "97.7"]} +{"pcdb_id": 18520, "brand_name": "Ideal", "model_name": "VOGUE MAX SYSTEM", "model_qualifier": "18", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 18.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018520", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "VOGUE MAX SYSTEM", "18", "41-796-23", "2018", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18.0", "18.0", "", "", "88.7", "79.7", "", "58.2", "", "2", "", "", "102", "1", "2", "40", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "89.8", "97.8", "", "", "", "", "96.3"]} +{"pcdb_id": 18521, "brand_name": "Ideal", "model_name": "VOGUE MAX SYSTEM", "model_qualifier": "18P", "winter_efficiency_pct": 89.7, "summer_efficiency_pct": 80.7, "comparative_hot_water_efficiency_pct": 59.0, "output_kw_max": 18.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018521", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "VOGUE MAX SYSTEM", "18P", "41-796-23", "2018", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "18.0", "18.0", "", "", "89.7", "80.7", "", "59.0", "", "2", "1", "", "102", "1", "2", "40", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "91.8", "100.0", "", "", "", "", "98.5"]} +{"pcdb_id": 18522, "brand_name": "Ideal", "model_name": "VOGUE MAX SYSTEM", "model_qualifier": "26", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 26.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018522", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "VOGUE MAX SYSTEM", "26", "41-796-24", "2018", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "26.0", "26.0", "", "", "88.7", "79.7", "", "58.2", "", "2", "", "", "102", "1", "2", "45", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "89.7", "97.8", "", "", "", "", "96.2"]} +{"pcdb_id": 18523, "brand_name": "Ideal", "model_name": "VOGUE MAX SYSTEM", "model_qualifier": "26P", "winter_efficiency_pct": 89.7, "summer_efficiency_pct": 80.7, "comparative_hot_water_efficiency_pct": 58.9, "output_kw_max": 26.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018523", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "VOGUE MAX SYSTEM", "26P", "41-796-24", "2018", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "26.0", "26.0", "", "", "89.7", "80.7", "", "58.9", "", "2", "1", "", "102", "1", "2", "45", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "91.7", "99.9", "", "", "", "", "98.4"]} +{"pcdb_id": 18524, "brand_name": "Ideal", "model_name": "VOGUE MAX SYSTEM", "model_qualifier": "32", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 32.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018524", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "VOGUE MAX SYSTEM", "32", "41-796-25", "2018", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "32.0", "32.0", "", "", "88.7", "79.7", "", "58.2", "", "2", "", "", "102", "1", "2", "49", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "89.8", "97.8", "", "", "", "", "96.3"]} +{"pcdb_id": 18525, "brand_name": "Ideal", "model_name": "VOGUE MAX SYSTEM", "model_qualifier": "32P", "winter_efficiency_pct": 89.7, "summer_efficiency_pct": 80.7, "comparative_hot_water_efficiency_pct": 59.0, "output_kw_max": 32.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018525", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "VOGUE MAX SYSTEM", "32P", "41-796-25", "2018", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "32.0", "32.0", "", "", "89.7", "80.7", "", "59.0", "", "2", "1", "", "102", "1", "2", "49", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "91.8", "100.0", "", "", "", "", "98.5"]} +{"pcdb_id": 18526, "brand_name": "HRM", "model_name": "WALLSTAR1", "model_qualifier": "LOW NOX CONDENSING 12 - 16 Kw", "winter_efficiency_pct": 86.6, "summer_efficiency_pct": 78.8, "comparative_hot_water_efficiency_pct": 57.6, "output_kw_max": 16.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018526", "000098", "0", "2019/Sep/10 13:23", "HRM Boilers", "HRM", "WALLSTAR1", "LOW NOX CONDENSING 12 - 16 Kw", "", "2018", "current", "4", "2", "1", "1", "0", "", "", "2", "2", "2", "12.0", "16.0", "", "", "86.6", "78.8", "", "57.6", "", "2", "", "", "201", "1", "1", "138", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "89.4", "91.9", "", "", "", "", "91.4"]} +{"pcdb_id": 18527, "brand_name": "Sime", "model_name": "MURELLE REVOLUTION", "model_qualifier": "30", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 86.9, "comparative_hot_water_efficiency_pct": 64.9, "output_kw_max": 19.7, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0008, "loss_factor_f1_kwh_per_day": 1.97056, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018527", "000213", "0", "2020/Jan/22 13:07", "Fonderie Sime S.p.A", "Sime", "MURELLE REVOLUTION", "30", "8116102", "2018", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "19.7", "19.7", "", "", "88.0", "86.9", "", "64.9", "", "2", "", "", "104", "1", "2", "29", "4", "0", "", "", "", "0", "", "", "", "", "1", "8.111", "0.279", "0.0008", "1.97056", "13.726", "0.295", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.6", "96.6", "", "", "", "", "95.1"]} +{"pcdb_id": 18528, "brand_name": "HRM", "model_name": "WALLSTAR2", "model_qualifier": "LOW NOX CONDENSING 12 - 20Kw", "winter_efficiency_pct": 87.8, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 20.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018528", "000098", "0", "2019/Sep/10 13:35", "HRM Boilers", "HRM", "WALLSTAR2", "LOW NOX CONDENSING 12 - 20Kw", "", "2018", "current", "4", "2", "1", "1", "0", "", "", "2", "2", "2", "12", "20", "", "", "87.8", "80.0", "", "58.4", "", "2", "", "", "201", "1", "1", "130", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.3", "94.4", "", "", "", "", "93.7"]} +{"pcdb_id": 18529, "brand_name": "HRM", "model_name": "WALLSTAR3", "model_qualifier": "LOW NOX CONDENSING 20 - 24Kw", "winter_efficiency_pct": 87.2, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 24.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018529", "000098", "0", "2019/Sep/10 13:40", "HRM Boilers", "HRM", "WALLSTAR3", "LOW NOX CONDENSING 20 - 24Kw", "", "2018", "current", "4", "2", "1", "1", "0", "", "", "2", "2", "2", "20", "24", "", "", "87.2", "79.4", "", "58.0", "", "2", "", "", "201", "1", "1", "139", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.1", "92.8", "", "", "", "", "92.4"]} +{"pcdb_id": 18530, "brand_name": "HRM", "model_name": "WALLSTAR COMBI", "model_qualifier": "LOW NOX CONDENSING", "winter_efficiency_pct": 87.4, "summer_efficiency_pct": 89.8, "comparative_hot_water_efficiency_pct": 49.4, "output_kw_max": 24.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0008, "loss_factor_f1_kwh_per_day": 4.77948, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018530", "000098", "0", "2020/Jan/22 13:08", "HRM Boilers", "HRM", "WALLSTAR COMBI", "LOW NOX CONDENSING", "", "2018", "current", "4", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "", "", "87.4", "89.8", "", "49.4", "", "2", "", "", "202", "1", "1", "131", "1", "0", "", "", "", "0", "", "", "", "", "1", "11.092", "0.099", "0.0008", "4.77948", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.4", "93.3", "", "", "", "", "92.8"]} +{"pcdb_id": 18531, "brand_name": "HRM", "model_name": "WALLSTAR 2 SYSTEM", "model_qualifier": "LOW NOX CONDENSING 12 - 20Kw", "winter_efficiency_pct": 87.8, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 20.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018531", "000098", "0", "2019/Sep/10 13:37", "HRM Boilers", "HRM", "WALLSTAR 2 SYSTEM", "LOW NOX CONDENSING 12 - 20Kw", "", "2018", "current", "4", "2", "1", "1", "0", "", "", "2", "2", "2", "12", "20", "", "", "87.8", "80.0", "", "58.4", "", "2", "", "", "201", "1", "1", "130", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.3", "94.4", "", "", "", "", "93.7"]} +{"pcdb_id": 18532, "brand_name": "EOGB", "model_name": "KERRO GREEN", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 80.6, "comparative_hot_water_efficiency_pct": 58.8, "output_kw_max": 20.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018532", "000311", "0", "2019/Mar/18 14:05", "EOGB Energy Products Ltd", "EOGB", "KERRO GREEN", "", "", "2018", "current", "4", "1", "1", "1", "0", "", "", "2", "2", "2", "20.5", "20.5", "", "", "88.4", "80.6", "", "58.8", "", "2", "", "", "201", "1", "2", "109", "7", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "4005", "", "", "", "", "", "", "", "", "92.0", "95.2", "", "", "", "", "94.6"]} +{"pcdb_id": 18533, "brand_name": "Ariston", "model_name": "CLAS ONE 30", "model_qualifier": "", "winter_efficiency_pct": 89.7, "summer_efficiency_pct": 81.1, "comparative_hot_water_efficiency_pct": 57.0, "output_kw_max": 27.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018533", "000080", "0", "2018/Dec/12 10:42", "Ariston Thermo S.p.A", "Ariston", "CLAS ONE 30", "", "3301044", "2017", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "27.4", "27.4", "", "", "89.7", "81.1", "", "57.0", "", "2", "0", "", "104", "1", "2", "39", "4", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0805", "", "", "", "", "", "", "", "", "89.9", "98.2", "", "", "", "", "96.6"]} +{"pcdb_id": 18534, "brand_name": "Ariston", "model_name": "CLAS ONE 38", "model_qualifier": "", "winter_efficiency_pct": 89.6, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 57.0, "output_kw_max": 30.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018534", "000080", "0", "2018/Dec/12 10:43", "Ariston Thermo S.p.A", "Ariston", "CLAS ONE 38", "", "3301045", "2017", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "30.2", "30.2", "", "", "89.6", "81.0", "", "57.0", "", "2", "0", "", "104", "1", "2", "35", "4", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0805", "", "", "", "", "", "", "", "", "89.6", "98.1", "", "", "", "", "96.5"]} +{"pcdb_id": 18535, "brand_name": "Ariston", "model_name": "CLAS SYSTEM ONE 18", "model_qualifier": "", "winter_efficiency_pct": 89.7, "summer_efficiency_pct": 80.7, "comparative_hot_water_efficiency_pct": 59.0, "output_kw_max": 17.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018535", "000080", "0", "2018/Dec/12 10:45", "Ariston Thermo S.p.A", "Ariston", "CLAS SYSTEM ONE 18", "", "3301046", "2017", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "17.6", "17.6", "", "", "89.7", "80.7", "", "59.0", "", "2", "0", "", "102", "1", "2", "24", "4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0805", "", "", "", "", "", "", "", "", "89.5", "98.4", "", "", "", "", "96.7"]} +{"pcdb_id": 18536, "brand_name": "Ariston", "model_name": "CLAS SYSTEM ONE 24", "model_qualifier": "", "winter_efficiency_pct": 89.7, "summer_efficiency_pct": 80.7, "comparative_hot_water_efficiency_pct": 59.0, "output_kw_max": 21.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018536", "000080", "0", "2018/Dec/12 10:45", "Ariston Thermo S.p.A", "Ariston", "CLAS SYSTEM ONE 24", "", "3301047", "2017", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "21.4", "21.4", "", "", "89.7", "80.7", "", "59.0", "", "2", "0", "", "102", "1", "2", "30", "4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0805", "", "", "", "", "", "", "", "", "89.4", "98.5", "", "", "", "", "96.7"]} +{"pcdb_id": 18537, "brand_name": "Ariston", "model_name": "CLAS SYSTEM ONE 30", "model_qualifier": "", "winter_efficiency_pct": 89.7, "summer_efficiency_pct": 80.7, "comparative_hot_water_efficiency_pct": 58.9, "output_kw_max": 27.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018537", "000080", "0", "2018/Dec/12 10:45", "Ariston Thermo S.p.A", "Ariston", "CLAS SYSTEM ONE 30", "", "3301048", "2017", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "27.4", "27.4", "", "", "89.7", "80.7", "", "58.9", "", "2", "0", "", "102", "1", "2", "35", "4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0805", "", "", "", "", "", "", "", "", "89.9", "98.2", "", "", "", "", "96.6"]} +{"pcdb_id": 18538, "brand_name": "Ariston", "model_name": "CLAS NET ONE 24", "model_qualifier": "", "winter_efficiency_pct": 89.7, "summer_efficiency_pct": 81.1, "comparative_hot_water_efficiency_pct": 57.1, "output_kw_max": 21.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018538", "000080", "0", "2018/Dec/12 10:46", "Ariston Thermo S.p.A", "Ariston", "CLAS NET ONE 24", "", "3301049", "2017", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "21.4", "21.4", "", "", "89.7", "81.1", "", "57.1", "", "2", "0", "", "104", "1", "2", "30", "4", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0805", "", "", "", "", "", "", "", "", "89.4", "98.5", "", "", "", "", "96.7"]} +{"pcdb_id": 18539, "brand_name": "Ariston", "model_name": "CLAS NET ONE 30", "model_qualifier": "", "winter_efficiency_pct": 89.7, "summer_efficiency_pct": 81.1, "comparative_hot_water_efficiency_pct": 57.0, "output_kw_max": 27.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018539", "000080", "0", "2018/Dec/12 10:46", "Ariston Thermo S.p.A", "Ariston", "CLAS NET ONE 30", "", "3301050", "2017", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "27.4", "27.4", "", "", "89.7", "81.1", "", "57.0", "", "2", "0", "", "104", "1", "2", "39", "4", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0805", "", "", "", "", "", "", "", "", "89.9", "98.2", "", "", "", "", "96.6"]} +{"pcdb_id": 18540, "brand_name": "Ariston", "model_name": "CLAS NET ONE 38", "model_qualifier": "", "winter_efficiency_pct": 89.6, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 57.0, "output_kw_max": 30.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018540", "000080", "0", "2018/Dec/12 10:46", "Ariston Thermo S.p.A", "Ariston", "CLAS NET ONE 38", "", "3301051", "2017", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "30.2", "30.2", "", "", "89.6", "81.0", "", "57.0", "", "2", "0", "", "104", "1", "2", "35", "4", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0805", "", "", "", "", "", "", "", "", "89.6", "98.1", "", "", "", "", "96.5"]} +{"pcdb_id": 18541, "brand_name": "Ariston", "model_name": "E-SYSTEM ONE 24", "model_qualifier": "", "winter_efficiency_pct": 89.7, "summer_efficiency_pct": 80.7, "comparative_hot_water_efficiency_pct": 59.0, "output_kw_max": 21.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018541", "000080", "0", "2018/Dec/12 10:46", "Ariston Thermo S.p.A", "Ariston", "E-SYSTEM ONE 24", "", "3301056", "2017", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "21.4", "21.4", "", "", "89.7", "80.7", "", "59.0", "", "2", "0", "", "102", "1", "2", "30", "4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0805", "", "", "", "", "", "", "", "", "89.4", "98.5", "", "", "", "", "96.7"]} +{"pcdb_id": 18542, "brand_name": "Ariston", "model_name": "E-SYSTEM ONE 30", "model_qualifier": "", "winter_efficiency_pct": 89.7, "summer_efficiency_pct": 80.7, "comparative_hot_water_efficiency_pct": 58.9, "output_kw_max": 27.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018542", "000080", "0", "2018/Dec/12 10:47", "Ariston Thermo S.p.A", "Ariston", "E-SYSTEM ONE 30", "", "3301057", "2017", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "27.4", "27.4", "", "", "89.7", "80.7", "", "58.9", "", "2", "0", "", "102", "1", "2", "39", "4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0805", "", "", "", "", "", "", "", "", "89.9", "98.2", "", "", "", "", "96.6"]} +{"pcdb_id": 18543, "brand_name": "Ariston", "model_name": "E-COMBI ONE 24", "model_qualifier": "", "winter_efficiency_pct": 89.7, "summer_efficiency_pct": 81.1, "comparative_hot_water_efficiency_pct": 57.1, "output_kw_max": 21.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018543", "000080", "0", "2018/Dec/12 10:47", "Ariston Thermo S.p.A", "Ariston", "E-COMBI ONE 24", "", "3301131", "2017", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "21.4", "21.4", "", "", "89.7", "81.1", "", "57.1", "", "2", "0", "", "104", "1", "2", "30", "4", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0805", "", "", "", "", "", "", "", "", "89.4", "98.5", "", "", "", "", "96.7"]} +{"pcdb_id": 18544, "brand_name": "Ariston", "model_name": "E-COMBI ONE 30", "model_qualifier": "", "winter_efficiency_pct": 89.7, "summer_efficiency_pct": 81.1, "comparative_hot_water_efficiency_pct": 57.0, "output_kw_max": 27.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018544", "000080", "0", "2018/Dec/12 10:47", "Ariston Thermo S.p.A", "Ariston", "E-COMBI ONE 30", "", "3301132", "2017", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "27.4", "27.4", "", "", "89.7", "81.1", "", "57.0", "", "2", "0", "", "104", "1", "2", "39", "4", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0805", "", "", "", "", "", "", "", "", "89.9", "98.2", "", "", "", "", "96.6"]} +{"pcdb_id": 18546, "brand_name": "Ferroli", "model_name": "BLUEHELIX TECH RRT", "model_qualifier": "24C", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 86.8, "comparative_hot_water_efficiency_pct": 75.6, "output_kw_max": 20.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0066, "loss_factor_f1_kwh_per_day": 0.82777, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018546", "000097", "0", "2020/Jan/22 13:08", "Ferroli", "Ferroli", "BLUEHELIX TECH RRT", "24C", "47-267-71", "2018", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "20.0", "20.0", "", "", "88.9", "86.8", "", "75.6", "", "2", "", "", "104", "1", "2", "22", "3", "0", "", "", "", "0", "", "", "", "", "1", "6.97", "0.119", "0.0066", "0.82777", "", "", "", "", "", "", "", "", "0015", "", "", "", "", "", "", "", "", "88.2", "99.0", "", "", "", "", "97.0"]} +{"pcdb_id": 18548, "brand_name": "Ferroli", "model_name": "BLUEHELIX TECH RRT", "model_qualifier": "28C", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 86.8, "comparative_hot_water_efficiency_pct": 76.0, "output_kw_max": 24.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0066, "loss_factor_f1_kwh_per_day": 0.78925, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018548", "000097", "0", "2020/Jan/22 13:08", "Ferroli", "Ferroli", "BLUEHELIX TECH RRT", "28C", "47-267-72", "2018", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.0", "24.0", "", "", "88.8", "86.8", "", "76.0", "", "2", "", "", "104", "1", "2", "28", "3", "0", "", "", "", "0", "", "", "", "", "1", "6.93", "0.12", "0.0066", "0.78925", "", "", "", "", "", "", "", "", "0015", "", "", "", "", "", "", "", "", "88.2", "98.8", "", "", "", "", "96.8"]} +{"pcdb_id": 18550, "brand_name": "Ferroli", "model_name": "BLUEHELIX TECH RRT", "model_qualifier": "34C", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 86.7, "comparative_hot_water_efficiency_pct": 74.8, "output_kw_max": 30.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0066, "loss_factor_f1_kwh_per_day": 0.88998, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018550", "000097", "0", "2020/Jan/22 13:08", "Ferroli", "Ferroli", "BLUEHELIX TECH RRT", "34C", "47-267-73", "2018", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "30.0", "30.0", "", "", "88.8", "86.7", "", "74.8", "", "2", "", "", "104", "1", "2", "36", "3", "0", "", "", "", "0", "", "", "", "", "1", "7.037", "0.118", "0.0066", "0.88998", "", "", "", "", "", "", "", "", "0015", "", "", "", "", "", "", "", "", "88.1", "98.8", "", "", "", "", "96.8"]} +{"pcdb_id": 18551, "brand_name": "Baxi", "model_name": "624 COMBI LPG", "model_qualifier": "24", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 56.8, "output_kw_max": 20.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018551", "000005", "0", "2018/Nov/23 14:12", "Baxi Heating UK", "Baxi", "624 COMBI LPG", "24", "47-077-33", "2018", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "20.0", "20.0", "", "", "89.4", "80.8", "", "56.8", "", "2", "1", "", "104", "1", "2", "28", "3", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "90.0", "99.9", "", "", "", "", "98.0"]} +{"pcdb_id": 18552, "brand_name": "Baxi", "model_name": "630 COMBI LPG", "model_qualifier": "30", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 56.8, "output_kw_max": 20.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018552", "000005", "0", "2018/Nov/23 14:13", "Baxi Heating", "Baxi", "630 COMBI LPG", "30", "47-077-32", "2018", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "20.0", "20.0", "", "", "89.4", "80.8", "", "56.8", "", "2", "1", "", "104", "1", "2", "38", "3", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "90.0", "99.9", "", "", "", "", "98.0"]} +{"pcdb_id": 18553, "brand_name": "Potterton", "model_name": "ASSURE 25 COMBI LPG", "model_qualifier": "25", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 56.8, "output_kw_max": 20.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018553", "000005", "0", "2018/Dec/10 11:14", "Baxi Heating", "Potterton", "ASSURE 25 COMBI LPG", "25", "47-393-70", "2018", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "20.0", "20.0", "", "", "89.4", "80.8", "", "56.8", "", "2", "1", "", "104", "1", "2", "28", "3", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "90.0", "99.9", "", "", "", "", "98.0"]} +{"pcdb_id": 18554, "brand_name": "Potterton", "model_name": "ASSURE 30 COMBI LPG", "model_qualifier": "30", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 56.9, "output_kw_max": 25.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018554", "000005", "0", "2019/Sep/12 10:16", "Baxi Heating", "Potterton", "ASSURE 30 COMBI LPG", "30", "47-393-69", "2018", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "25.0", "25.0", "", "", "89.4", "80.8", "", "56.9", "", "2", "1", "", "104", "1", "2", "38", "3", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "90.1", "100.0", "", "", "", "", "98.1"]} +{"pcdb_id": 18555, "brand_name": "Trianco", "model_name": "TRO EVOLUTION 20 KITCHEN HEAT ONLY", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 59.2, "output_kw_max": 20.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018555", "000062", "0", "2018/Nov/14 16:10", "TR Engineering Ltd", "Trianco", "TRO EVOLUTION 20 KITCHEN HEAT ONLY", "", "", "2018", "current", "4", "1", "1", "1", "0", "", "", "2", "2", "2", "20.0", "20.0", "", "", "88.8", "81.0", "", "59.2", "", "2", "", "", "201", "1", "1", "217", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.1", "96.8", "", "", "", "", "95.7"]} +{"pcdb_id": 18556, "brand_name": "Trianco", "model_name": "TRO EVOLUTION 30 KITCHEN HEAT ONLY", "model_qualifier": "", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 81.1, "comparative_hot_water_efficiency_pct": 59.3, "output_kw_max": 30.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018556", "000062", "0", "2018/Nov/14 16:10", "TR Engineering Ltd", "Trianco", "TRO EVOLUTION 30 KITCHEN HEAT ONLY", "", "", "2018", "current", "4", "1", "1", "1", "0", "", "", "2", "2", "2", "30.0", "30.0", "", "", "88.9", "81.1", "", "59.3", "", "2", "", "", "201", "1", "1", "217", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.9", "97.2", "", "", "", "", "96.0"]} +{"pcdb_id": 18557, "brand_name": "Sime", "model_name": "MURELLE ONE HE", "model_qualifier": "30", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 75.7, "comparative_hot_water_efficiency_pct": 62.1, "output_kw_max": 23.7, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.0, "loss_factor_f1_kwh_per_day": 2.3402, "loss_factor_f2_kwh_per_day": 1.13131, "rejected_factor_f3_per_litre": -4e-05, "raw": ["018557", "000213", "0", "2020/Apr/09 16:21", "Fonderie Sime", "Sime", "MURELLE ONE HE", "30", "8115012", "2018", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "23.7", "23.7", "", "", "88.5", "75.7", "", "62.1", "", "2", "", "", "104", "1", "2", "32", "4", "0", "", "", "", "0", "", "", "", "", "2", "8.478", "0.114", "0.0", "2.3402", "15.446", "0.127", "0.0035", "1.13131", "-0.00004", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.9", "97.8", "", "", "", "", "96.1"]} +{"pcdb_id": 18559, "brand_name": "Main", "model_name": "ECO COMPACT 25 COMBI", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 56.1, "output_kw_max": 20.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018559", "000005", "0", "2018/Dec/13 10:26", "Baxi Heating", "Main", "ECO COMPACT 25 COMBI", "", "47-467-14", "2018", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "20.0", "20.0", "", "", "88.4", "79.8", "", "56.1", "", "2", "", "", "104", "1", "2", "28", "3", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "88.0", "97.8", "", "", "", "", "95.9"]} +{"pcdb_id": 18560, "brand_name": "Main", "model_name": "ECO COMPACT 30 COMBI", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 56.1, "output_kw_max": 25.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018560", "000005", "0", "2018/Dec/13 10:26", "Baxi Heating", "Main", "ECO COMPACT 30 COMBI", "", "47-467-15", "2018", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "25.0", "25.0", "", "", "88.4", "79.8", "", "56.1", "", "2", "", "", "104", "1", "2", "28", "3", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "88.0", "97.8", "", "", "", "", "95.9"]} +{"pcdb_id": 18561, "brand_name": "Main", "model_name": "ECO COMPACT 15 SYSTEM", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 15.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018561", "000005", "0", "2018/Dec/13 09:27", "Baxi Heating", "Main", "ECO COMPACT 15 SYSTEM", "", "41-467-30", "2018", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "15.0", "15.0", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "25", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "88.2", "97.8", "", "", "", "", "95.9"]} +{"pcdb_id": 18562, "brand_name": "Main", "model_name": "ECO COMPACT 18 SYSTEM", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 18.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018562", "000005", "0", "2018/Dec/13 09:27", "Baxi Heating", "Main", "ECO COMPACT 18 SYSTEM", "", "47-467-31", "2018", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18.0", "18.0", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "25", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "88.2", "97.8", "", "", "", "", "96.0"]} +{"pcdb_id": 18563, "brand_name": "Worcester", "model_name": "GREENSTAR UTILITY REGULAR ErP+", "model_qualifier": "50/70", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 70.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018563", "000035", "0", "2018/Nov/26 16:42", "Bosch Thermotechnology", "Worcester", "GREENSTAR UTILITY REGULAR ErP+", "50/70", "", "2018", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "50.0", "70.0", "", "", "88.0", "80.2", "", "58.6", "", "2", "", "", "201", "1", "1", "182", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.4", "94.5", "", "", "", "", "93.9"]} +{"pcdb_id": 18564, "brand_name": "Ariston", "model_name": "CARES ONE 24", "model_qualifier": "", "winter_efficiency_pct": 87.7, "summer_efficiency_pct": 85.1, "comparative_hot_water_efficiency_pct": 75.2, "output_kw_max": 21.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.003, "loss_factor_f1_kwh_per_day": 0.75113, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018564", "000080", "0", "2020/Jan/22 13:08", "Ariston Thermo S.p.A", "Ariston", "CARES ONE 24", "", "3301054", "2017", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "21.3", "21.3", "", "", "87.7", "85.1", "", "75.2", "", "2", "", "", "104", "1", "2", "33", "4", "0", "", "", "", "0", "", "", "", "", "1", "7.006", "0.121", "0.003", "0.75113", "", "", "", "", "", "", "", "", "0805", "", "", "", "", "", "", "", "", "85.1", "98.1", "", "", "", "", "95.6"]} +{"pcdb_id": 18565, "brand_name": "Ariston", "model_name": "CARES ONE 30", "model_qualifier": "", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 86.8, "comparative_hot_water_efficiency_pct": 72.7, "output_kw_max": 27.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.007, "loss_factor_f1_kwh_per_day": 1.08414, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018565", "000080", "0", "2020/Jan/22 13:08", "Ariston Thermo S.p.A", "Ariston", "CARES ONE 30", "", "3301055", "2017", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "27.4", "27.4", "", "", "88.9", "86.8", "", "72.7", "", "2", "", "", "104", "1", "2", "40", "4", "0", "", "", "", "0", "", "", "", "", "1", "7.239", "0.14", "0.007", "1.08414", "", "", "", "", "", "", "", "", "0805", "", "", "", "", "", "", "", "", "88.2", "98.9", "", "", "", "", "96.9"]} +{"pcdb_id": 18566, "brand_name": "Vaillant", "model_name": "ecoFIT pure 830 P", "model_qualifier": "VUW 306/6-3 (P-GB)", "winter_efficiency_pct": 90.4, "summer_efficiency_pct": 81.8, "comparative_hot_water_efficiency_pct": 57.5, "output_kw_max": 30.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018566", "000031", "0", "2019/Feb/18 16:30", "Vaillant", "Vaillant", "ecoFIT pure 830 P", "VUW 306/6-3 (P-GB)", "47-044-75", "2018", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "30.6", "30.6", "", "", "90.4", "81.8", "", "57.5", "", "2", "0", "", "104", "1", "2", "31", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0045", "", "", "", "", "", "", "", "", "90.7", "99.7", "", "", "", "", "98.0"]} +{"pcdb_id": 18567, "brand_name": "Worcester", "model_name": "Greenstar Utility Regular 32/50 ErP +", "model_qualifier": "", "winter_efficiency_pct": 87.5, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 50.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018567", "000035", "0", "2019/Jan/02 15:38", "Bosch Thermotechnology", "Worcester", "Greenstar Utility Regular 32/50 ErP +", "", "", "2018", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "32", "50", "", "", "87.5", "79.7", "", "58.2", "", "2", "", "", "201", "1", "1", "192", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.2", "93.4", "", "", "", "", "93.0"]} +{"pcdb_id": 18568, "brand_name": "Ariston", "model_name": "ALTEAS ONE NET 30", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 86.9, "comparative_hot_water_efficiency_pct": 73.0, "output_kw_max": 27.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.008, "loss_factor_f1_kwh_per_day": 1.06506, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018568", "000080", "0", "2020/Jan/22 13:09", "Ariston Thermo S.p.A", "Ariston", "ALTEAS ONE NET 30", "", "3301449", "2017", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "27.5", "27.5", "", "", "88.8", "86.9", "", "73.0", "", "2", "", "", "104", "1", "2", "42", "5", "0", "", "", "", "0", "", "", "", "", "1", "7.213", "0.166", "0.008", "1.06506", "", "", "", "", "", "", "", "", "0805", "", "", "", "", "", "", "", "", "88.7", "98.7", "", "", "", "", "96.8"]} +{"pcdb_id": 18569, "brand_name": "Ariston", "model_name": "ALTEAS ONE NET 35", "model_qualifier": "", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 86.7, "comparative_hot_water_efficiency_pct": 73.0, "output_kw_max": 31.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0041, "loss_factor_f1_kwh_per_day": 1.06942, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018569", "000080", "0", "2020/Jan/22 13:09", "Ariston Thermo S.p.A", "Ariston", "ALTEAS ONE NET 35", "", "3301450", "2017", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "31.0", "31.0", "", "", "88.7", "86.7", "", "73.0", "", "2", "", "", "104", "1", "2", "42", "5", "0", "", "", "", "0", "", "", "", "", "1", "7.211", "0.157", "0.0041", "1.06942", "", "", "", "", "", "", "", "", "0805", "", "", "", "", "", "", "", "", "88.0", "98.7", "", "", "", "", "96.6"]} +{"pcdb_id": 18570, "brand_name": "Ariston", "model_name": "GENUS ONE NET 30", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 86.9, "comparative_hot_water_efficiency_pct": 73.0, "output_kw_max": 27.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0082, "loss_factor_f1_kwh_per_day": 1.06389, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018570", "000080", "0", "2020/Jan/22 13:09", "Ariston Thermo S.p.A", "Ariston", "GENUS ONE NET 30", "", "3301452", "2017", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "27.5", "27.5", "", "", "88.8", "86.9", "", "73.0", "", "2", "", "", "104", "1", "2", "42", "5", "0", "", "", "", "0", "", "", "", "", "1", "7.213", "0.166", "0.0082", "1.06389", "", "", "", "", "", "", "", "", "0805", "", "", "", "", "", "", "", "", "88.7", "98.7", "", "", "", "", "96.8"]} +{"pcdb_id": 18571, "brand_name": "Ariston", "model_name": "GENUS ONE NET 24", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 86.7, "comparative_hot_water_efficiency_pct": 70.9, "output_kw_max": 21.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.008, "loss_factor_f1_kwh_per_day": 1.25927, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018571", "000080", "0", "2020/Jan/22 13:09", "Ariston Thermo S.p.A", "Ariston", "GENUS ONE NET 24", "", "3301451", "2017", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "21.5", "21.5", "", "", "88.8", "86.7", "", "70.9", "", "2", "", "", "104", "1", "2", "33", "6", "0", "", "", "", "0", "", "", "", "", "1", "7.432", "0.128", "0.008", "1.25927", "", "", "", "", "", "", "", "", "0805", "", "", "", "", "", "", "", "", "88.0", "98.9", "", "", "", "", "96.9"]} +{"pcdb_id": 18572, "brand_name": "Ariston", "model_name": "GENUS ONE NET 35", "model_qualifier": "", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 86.7, "comparative_hot_water_efficiency_pct": 73.0, "output_kw_max": 31.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0041, "loss_factor_f1_kwh_per_day": 1.06942, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018572", "000080", "0", "2020/Jan/22 13:09", "Ariston Thermo S.p.A", "Ariston", "GENUS ONE NET 35", "", "3301453", "2017", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "31.0", "31.0", "", "", "88.7", "86.7", "", "73.0", "", "2", "", "", "104", "1", "2", "42", "5", "0", "", "", "", "0", "", "", "", "", "1", "7.211", "0.157", "0.0041", "1.06942", "", "", "", "", "", "", "", "", "0805", "", "", "", "", "", "", "", "", "88.0", "98.7", "", "", "", "", "96.6"]} +{"pcdb_id": 18573, "brand_name": "Firebird", "model_name": "Envirogreen Combi HE Condensing Boiler", "model_qualifier": "20kW", "winter_efficiency_pct": 89.3, "summer_efficiency_pct": 81.9, "comparative_hot_water_efficiency_pct": 57.6, "output_kw_max": 20.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018573", "000047", "0", "2019/Jan/18 10:25", "Firebird Heating Solutions Ltd", "Firebird", "Envirogreen Combi HE Condensing Boiler", "20kW", "", "2018", "current", "4", "1", "1", "2", "0", "", "", "2", "2", "1", "20.0", "20.0", "", "", "89.3", "81.9", "", "57.6", "", "2", "", "", "202", "1", "1", "155", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "", "", "0003", "", "", "", "", "", "", "", "", "92.8", "97.4", "", "", "", "", "96.5"]} +{"pcdb_id": 18574, "brand_name": "Firebird", "model_name": "Envirogreen Combi HE Condensing Boiler", "model_qualifier": "26kW", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 81.7, "comparative_hot_water_efficiency_pct": 57.5, "output_kw_max": 26.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018574", "000047", "0", "2019/Jan/18 10:25", "Firebird Heating Solutions Ltd", "Firebird", "Envirogreen Combi HE Condensing Boiler", "26kW", "", "2018", "current", "4", "1", "1", "2", "0", "", "", "2", "2", "1", "26.0", "26.0", "", "", "89.1", "81.7", "", "57.5", "", "2", "", "", "202", "1", "1", "143", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "92.7", "96.9", "", "", "", "", "96.1"]} +{"pcdb_id": 18575, "brand_name": "Firebird", "model_name": "Envirogreen Combi HE Condensing Boiler", "model_qualifier": "35kW", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 81.3, "comparative_hot_water_efficiency_pct": 57.2, "output_kw_max": 35.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018575", "000047", "0", "2019/Jan/18 10:24", "Firebird Heating Solutions Ltd", "Firebird", "Envirogreen Combi HE Condensing Boiler", "35kW", "", "2018", "current", "4", "1", "1", "2", "0", "", "", "2", "2", "1", "35.0", "35.0", "", "", "88.7", "81.3", "", "57.2", "", "2", "", "", "202", "1", "1", "138", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "92.5", "95.9", "", "", "", "", "95.2"]} +{"pcdb_id": 18576, "brand_name": "Firebird", "model_name": "Envirogreen Combipac HE", "model_qualifier": "20kW", "winter_efficiency_pct": 89.3, "summer_efficiency_pct": 81.9, "comparative_hot_water_efficiency_pct": 57.6, "output_kw_max": 20.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018576", "000047", "0", "2019/Jan/18 10:24", "Firebird Heating Solutions Ltd", "Firebird", "Envirogreen Combipac HE", "20kW", "", "2018", "current", "4", "1", "1", "2", "0", "", "", "2", "2", "1", "20.0", "20.0", "", "", "89.3", "81.9", "", "57.6", "", "2", "", "", "202", "1", "1", "155", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "92.8", "97.4", "", "", "", "", "96.5"]} +{"pcdb_id": 18577, "brand_name": "Firebird", "model_name": "Envirogreen Combipac HE", "model_qualifier": "26kW", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 81.7, "comparative_hot_water_efficiency_pct": 57.5, "output_kw_max": 26.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018577", "000047", "0", "2019/Jan/18 10:24", "Firebird Heating Solutions Ltd", "Firebird", "Envirogreen Combipac HE", "26kW", "", "2018", "current", "4", "1", "1", "2", "0", "", "", "2", "2", "1", "26.0", "26.0", "", "", "89.1", "81.7", "", "57.5", "", "2", "", "", "202", "1", "1", "143", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "92.7", "96.9", "", "", "", "", "96.1"]} +{"pcdb_id": 18578, "brand_name": "Firebird", "model_name": "Envirogreen Combipac HE", "model_qualifier": "35kW", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 81.3, "comparative_hot_water_efficiency_pct": 57.2, "output_kw_max": 35.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018578", "000047", "0", "2019/Jan/18 10:24", "Firebird Heating Solutions Ltd", "Firebird", "Envirogreen Combipac HE", "35kW", "", "2018", "current", "4", "1", "1", "2", "0", "", "", "2", "2", "1", "35.0", "35.0", "", "", "88.7", "81.3", "", "57.2", "", "2", "", "", "202", "1", "1", "138", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "92.5", "95.9", "", "", "", "", "95.2"]} +{"pcdb_id": 18579, "brand_name": "Potterton", "model_name": "ASSURE", "model_qualifier": "12 SYSTEM", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 12.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018579", "000005", "0", "2019/Aug/09 14:26", "Baxi Heating UK", "Potterton", "ASSURE", "12 SYSTEM", "41-594-12", "2018", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "12.0", "12.0", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "20", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "88.2", "97.8", "", "", "", "", "96.0"]} +{"pcdb_id": 18580, "brand_name": "Potterton", "model_name": "ASSURE", "model_qualifier": "24 SYSTEM", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 24.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018580", "000005", "0", "2019/Aug/09 14:34", "Baxi Heating UK", "Potterton", "ASSURE", "24 SYSTEM", "41-594-13", "2018", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24.0", "24.0", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "60", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "88.0", "97.8", "", "", "", "", "95.9"]} +{"pcdb_id": 18581, "brand_name": "Potterton", "model_name": "ASSURE", "model_qualifier": "18 SYSTEM LPG", "winter_efficiency_pct": 89.5, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 58.8, "output_kw_max": 18.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018581", "000005", "0", "2019/Aug/09 14:36", "Baxi Heating UK", "Potterton", "ASSURE", "18 SYSTEM LPG", "41-592-96", "2018", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "18.0", "18.0", "", "", "89.5", "80.5", "", "58.8", "", "2", "1", "", "102", "1", "2", "30", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "90.2", "100.0", "", "", "", "", "98.1"]} +{"pcdb_id": 18582, "brand_name": "Potterton", "model_name": "ASSURE", "model_qualifier": "24 SYSTEM LPG", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 80.4, "comparative_hot_water_efficiency_pct": 58.7, "output_kw_max": 24.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018582", "000005", "0", "2019/Aug/09 14:39", "Baxi Heating UK", "Potterton", "ASSURE", "24 SYSTEM LPG", "41-594-16", "2018", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "24.0", "24.0", "", "", "89.4", "80.4", "", "58.7", "", "2", "1", "", "102", "1", "2", "60", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "90.0", "99.9", "", "", "", "", "98.0"]} +{"pcdb_id": 18583, "brand_name": "Baxi", "model_name": "615 SYSTEM", "model_qualifier": "15", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 15.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018583", "000005", "0", "2019/Aug/09 14:03", "Baxi Heating UK", "Baxi", "615 SYSTEM", "15", "41-470-56", "2018", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "15.0", "15.0", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "25", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "88.2", "97.8", "", "", "", "", "95.9"]} +{"pcdb_id": 18584, "brand_name": "Baxi", "model_name": "618 SYSTEM", "model_qualifier": "18", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 18.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018584", "000005", "0", "2019/Aug/09 14:13", "Baxi Heating UK", "Baxi", "618 SYSTEM", "18", "41-470-57", "2018", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18.0", "18.0", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "30", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "88.2", "97.8", "", "", "", "", "96.0"]} +{"pcdb_id": 18585, "brand_name": "Baxi", "model_name": "624 SYSTEM", "model_qualifier": "24", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 24.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018585", "000005", "0", "2019/Aug/09 14:15", "Baxi Heating UK", "Baxi", "624 SYSTEM", "24", "41-470-59", "2018", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24.0", "24.0", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "60", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "88.0", "97.8", "", "", "", "", "95.9"]} +{"pcdb_id": 18586, "brand_name": "Baxi", "model_name": "624 SYSTEM", "model_qualifier": "24 LPG", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 80.4, "comparative_hot_water_efficiency_pct": 58.7, "output_kw_max": 24.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018586", "000005", "0", "2019/Aug/09 14:20", "Baxi Heating UK", "Baxi", "624 SYSTEM", "24 LPG", "41-470-64", "2018", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "24.0", "24.0", "", "", "89.4", "80.4", "", "58.7", "", "2", "1", "", "102", "1", "2", "60", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "90.0", "99.9", "", "", "", "", "98.0"]} +{"pcdb_id": 18587, "brand_name": "Intergas", "model_name": "Xclusive 24", "model_qualifier": "", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 86.6, "comparative_hot_water_efficiency_pct": 73.3, "output_kw_max": 18.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0, "loss_factor_f1_kwh_per_day": 1.05872, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018587", "000256", "0", "2020/Jan/22 13:09", "Intergas Heating Ltd", "Intergas", "Xclusive 24", "", "47-291-13", "2018", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "18.2", "18.2", "", "", "88.2", "86.6", "", "73.3", "", "2", "", "", "104", "1", "2", "100", "2", "0", "", "", "", "0", "", "", "", "", "1", "7.1823", "0.0437", "0.0", "1.05872", "", "", "", "", "", "", "", "", "0015", "", "", "", "", "", "", "", "", "87.8", "97.4", "", "", "", "", "95.6"]} +{"pcdb_id": 18588, "brand_name": "Intergas", "model_name": "Xclusive 30", "model_qualifier": "", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 86.7, "comparative_hot_water_efficiency_pct": 73.8, "output_kw_max": 23.7, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0, "loss_factor_f1_kwh_per_day": 1.01523, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018588", "000256", "0", "2020/Jan/22 13:09", "Intergas Heating Ltd", "Intergas", "Xclusive 30", "", "47-291-14", "2018", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "23.7", "23.7", "", "", "88.2", "86.7", "", "73.8", "", "2", "", "", "104", "1", "2", "100", "2", "0", "", "", "", "0", "", "", "", "", "1", "7.1322", "0.039", "0.0", "1.01523", "", "", "", "", "", "", "", "", "0015", "", "", "", "", "", "", "", "", "87.9", "97.2", "", "", "", "", "95.5"]} +{"pcdb_id": 18589, "brand_name": "Intergas", "model_name": "Xclusive 36", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 87.0, "comparative_hot_water_efficiency_pct": 76.7, "output_kw_max": 27.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0, "loss_factor_f1_kwh_per_day": 0.78648, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018589", "000256", "0", "2020/Jan/22 13:09", "Intergas Heating Ltd", "Intergas", "Xclusive 36", "", "47-291-15", "2018", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "27.0", "27.0", "", "", "88.5", "87.0", "", "76.7", "", "2", "", "", "104", "1", "2", "100", "2", "0", "", "", "", "0", "", "", "", "", "1", "6.8687", "0.0371", "0.0", "0.78648", "", "", "", "", "", "", "", "", "0015", "", "", "", "", "", "", "", "", "88.9", "97.6", "", "", "", "", "95.9"]} +{"pcdb_id": 18590, "brand_name": "Intergas", "model_name": "Xtreme 24", "model_qualifier": "", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 86.6, "comparative_hot_water_efficiency_pct": 82.8, "output_kw_max": 18.7, "final_year_of_manufacture": null, "subsidiary_type": 1, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0005, "loss_factor_f1_kwh_per_day": 0.26225, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018590", "000256", "0", "2020/Jan/22 13:09", "Intergas Heating Ltd", "Intergas", "Xtreme 24", "", "47-291-10", "2018", "current", "1", "2", "1", "2", "1", "", "", "2", "2", "2", "18.7", "18.7", "", "", "88.2", "86.6", "", "82.8", "", "2", "", "", "104", "1", "2", "100", "2", "0", "", "", "", "0", "", "", "", "", "1", "6.357", "0.039", "0.0005", "0.26225", "", "", "", "", "", "", "", "", "0015", "", "", "", "", "", "", "", "", "87.8", "97.4", "", "", "", "", "95.6"]} +{"pcdb_id": 18591, "brand_name": "Intergas", "model_name": "Xtreme 30", "model_qualifier": "", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 86.7, "comparative_hot_water_efficiency_pct": 82.0, "output_kw_max": 23.7, "final_year_of_manufacture": null, "subsidiary_type": 1, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0, "loss_factor_f1_kwh_per_day": 0.33115, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018591", "000256", "0", "2020/Jan/22 13:09", "Intergas Heating Ltd", "Intergas", "Xtreme 30", "", "47-291-11", "2018", "current", "1", "2", "1", "2", "1", "", "", "2", "2", "2", "23.7", "23.7", "", "", "88.2", "86.7", "", "82.0", "", "2", "", "", "104", "1", "2", "100", "2", "0", "", "", "", "0", "", "", "", "", "1", "6.421", "0.0385", "0.0", "0.33115", "", "", "", "", "", "", "", "", "0015", "", "", "", "", "", "", "", "", "87.9", "97.2", "", "", "", "", "95.5"]} +{"pcdb_id": 18592, "brand_name": "Intergas", "model_name": "Xtreme 36", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 87.0, "comparative_hot_water_efficiency_pct": 82.1, "output_kw_max": 27.0, "final_year_of_manufacture": null, "subsidiary_type": 1, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0, "loss_factor_f1_kwh_per_day": 0.34845, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018592", "000256", "0", "2020/Jan/22 13:09", "Intergas Heating Ltd", "Intergas", "Xtreme 36", "", "47-291-12", "2018", "current", "1", "2", "1", "2", "1", "", "", "2", "2", "2", "27.0", "27.0", "", "", "88.5", "87.0", "", "82.1", "", "2", "", "", "104", "1", "2", "100", "2", "0", "", "", "", "0", "", "", "", "", "1", "6.415", "0.037", "0.0", "0.34845", "", "", "", "", "", "", "", "", "0015", "", "", "", "", "", "", "", "", "88.9", "97.6", "", "", "", "", "95.9"]} +{"pcdb_id": 18593, "brand_name": "Glow-worm", "model_name": "Energy2 30c", "model_qualifier": "-A (P-GB)", "winter_efficiency_pct": 90.4, "summer_efficiency_pct": 81.8, "comparative_hot_water_efficiency_pct": 57.5, "output_kw_max": 30.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018593", "000207", "0", "2019/May/01 15:21", "Glow-worm", "Glow-worm", "Energy2 30c", "-A (P-GB)", "47-019-38", "2018", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "1", "30.6", "30.6", "", "", "90.4", "81.8", "", "57.5", "", "2", "0", "", "104", "1", "2", "31", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0085", "", "", "", "", "", "", "", "", "90.7", "99.7", "", "", "", "", "98.0"]} +{"pcdb_id": 18598, "brand_name": "Daikin", "model_name": "EHY2KOMB28AA", "model_qualifier": "", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 86.7, "comparative_hot_water_efficiency_pct": 72.3, "output_kw_max": 23.1, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0094, "loss_factor_f1_kwh_per_day": 1.1037, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018598", "000278", "0", "2020/Jan/22 13:09", "Daikin Europe NV", "Daikin", "EHY2KOMB28AA", "", "", "2019", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "23.1", "23.1", "", "", "88.2", "86.7", "", "72.3", "", "2", "", "", "104", "1", "2", "45", "2", "0", "", "", "", "0", "", "", "", "", "1", "7.281", "0.138", "0.0094", "1.1037", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "97.2", "", "", "", "", "95.5"]} +{"pcdb_id": 18599, "brand_name": "Daikin", "model_name": "EHY2KOMB32AA", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 87.0, "comparative_hot_water_efficiency_pct": 74.4, "output_kw_max": 26.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0009, "loss_factor_f1_kwh_per_day": 0.98426, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018599", "000278", "0", "2020/Jan/22 13:10", "Daikin Europe NV", "Daikin", "EHY2KOMB32AA", "", "", "2019", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "26.2", "26.2", "", "", "88.5", "87.0", "", "74.4", "", "2", "", "", "104", "1", "2", "45", "2", "0", "", "", "", "0", "", "", "", "", "1", "7.079", "0.05", "0.0009", "0.98426", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.9", "97.6", "", "", "", "", "95.9"]} +{"pcdb_id": 18600, "brand_name": "Firebird", "model_name": "Envirogreen Kitchen Condensing Boiler", "model_qualifier": "12-18kW", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 59.1, "output_kw_max": 18.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018600", "000047", "0", "2019/Oct/21 15:46", "Firebird Heating Solutions Ltd", "Firebird", "Envirogreen Kitchen Condensing Boiler", "12-18kW", "", "2018", "current", "4", "1", "1", "1", "0", "", "", "2", "2", "1", "12.0", "18.0", "", "", "88.8", "81.0", "", "59.1", "", "2", "", "", "201", "1", "1", "187", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "92.2", "96.1", "", "", "", "", "95.4"]} +{"pcdb_id": 18601, "brand_name": "Firebird", "model_name": "Envirogreen Heatpac Condensing Boiler", "model_qualifier": "12-18kW", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 59.1, "output_kw_max": 18.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018601", "000047", "0", "2019/Jul/08 15:16", "Firebird Heating Solutions Ltd", "Firebird", "Envirogreen Heatpac Condensing Boiler", "12-18kW", "", "2018", "current", "4", "1", "2", "1", "0", "", "", "2", "2", "1", "12.0", "18.0", "", "", "88.8", "81.0", "", "59.1", "", "2", "", "", "201", "1", "1", "187", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "92.2", "96.1", "", "", "", "", "95.4"]} +{"pcdb_id": 18602, "brand_name": "Firebird", "model_name": "Envirogreen Popular Condensing Boiler", "model_qualifier": "12-18kW", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 59.1, "output_kw_max": 18.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018602", "000047", "0", "2019/Jul/08 15:16", "Firebird Heating Solutions Ltd", "Firebird", "Envirogreen Popular Condensing Boiler", "12-18kW", "", "2018", "current", "4", "1", "1", "1", "0", "", "", "2", "2", "1", "12.0", "18.0", "", "", "88.8", "81.0", "", "59.1", "", "2", "", "", "201", "1", "1", "187", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "92.2", "96.1", "", "", "", "", "95.4"]} +{"pcdb_id": 18603, "brand_name": "Firebird", "model_name": "Envirogreen Slimline Heatpac Condensing Boiler", "model_qualifier": "12-18kW", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 59.1, "output_kw_max": 18.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018603", "000047", "0", "2019/Oct/21 15:46", "Firebird Heating Solutions Ltd", "Firebird", "Envirogreen Slimline Heatpac Condensing Boiler", "12-18kW", "", "2018", "current", "4", "1", "2", "1", "0", "", "", "2", "2", "1", "12.0", "18.0", "", "", "88.8", "81.0", "", "59.1", "", "2", "", "", "201", "1", "1", "187", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "92.2", "96.1", "", "", "", "", "95.4"]} +{"pcdb_id": 18604, "brand_name": "Firebird", "model_name": "Envirogreen Kitchen", "model_qualifier": "36-44kW", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 81.2, "comparative_hot_water_efficiency_pct": 59.3, "output_kw_max": 44.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018604", "000047", "0", "2019/Oct/21 15:46", "Firebird Heating Solutions Ltd", "Firebird", "Envirogreen Kitchen", "36-44kW", "", "2018", "current", "4", "1", "1", "1", "0", "", "", "2", "2", "1", "36.0", "44.0", "", "", "89.0", "81.2", "", "59.3", "", "2", "", "", "201", "1", "1", "160", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "92.6", "96.7", "", "", "", "", "95.9"]} +{"pcdb_id": 18605, "brand_name": "Firebird", "model_name": "Envirogreen Popular", "model_qualifier": "36-44kW", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 81.2, "comparative_hot_water_efficiency_pct": 59.3, "output_kw_max": 44.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018605", "000047", "0", "2019/Oct/21 15:46", "Firebird Heating Solutions Ltd", "Firebird", "Envirogreen Popular", "36-44kW", "", "2018", "current", "4", "1", "1", "1", "0", "", "", "2", "2", "1", "36.0", "44.0", "", "", "89.0", "81.2", "", "59.3", "", "2", "", "", "201", "1", "1", "160", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "92.6", "96.7", "", "", "", "", "95.9"]} +{"pcdb_id": 18606, "brand_name": "Firebird", "model_name": "Envirogreen System", "model_qualifier": "36-44kW", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 81.2, "comparative_hot_water_efficiency_pct": 59.3, "output_kw_max": 44.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018606", "000047", "0", "2019/Oct/21 15:46", "Firebird Heating Solutions Ltd", "Firebird", "Envirogreen System", "36-44kW", "", "2018", "current", "4", "1", "1", "1", "0", "", "", "2", "2", "1", "36.0", "44.0", "", "", "89.0", "81.2", "", "59.3", "", "2", "", "", "201", "1", "1", "160", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "92.6", "96.7", "", "", "", "", "95.9"]} +{"pcdb_id": 18607, "brand_name": "Firebird", "model_name": "Envirogreen Systempac", "model_qualifier": "36-44kW", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 81.2, "comparative_hot_water_efficiency_pct": 59.3, "output_kw_max": 44.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018607", "000047", "0", "2019/Oct/21 15:47", "Firebird Heating Solutions Ltd", "Firebird", "Envirogreen Systempac", "36-44kW", "", "2018", "current", "4", "1", "2", "1", "0", "", "", "2", "2", "1", "36.0", "44.0", "", "", "89.0", "81.2", "", "59.3", "", "2", "", "", "201", "1", "1", "160", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "92.6", "96.7", "", "", "", "", "95.9"]} +{"pcdb_id": 18608, "brand_name": "Firebird", "model_name": "Envirogreen Heatpac", "model_qualifier": "36-44kW", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 81.2, "comparative_hot_water_efficiency_pct": 59.3, "output_kw_max": 44.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018608", "000047", "0", "2019/Oct/21 15:47", "Firebird Heating Solutions Ltd", "Firebird", "Envirogreen Heatpac", "36-44kW", "", "2018", "current", "4", "1", "2", "1", "0", "", "", "2", "2", "1", "36.0", "44.0", "", "", "89.0", "81.2", "", "59.3", "", "2", "", "", "201", "1", "1", "160", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "92.6", "96.7", "", "", "", "", "95.9"]} +{"pcdb_id": 18609, "brand_name": "Biasi", "model_name": "ADVANCE 15OV", "model_qualifier": "41-583-35", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 78.9, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 16.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018609", "000208", "0", "2019/Jun/12 12:00", "Biasi (UK)", "Biasi", "ADVANCE 15OV", "41-583-35", "", "2019", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "16.5", "16.5", "", "", "87.9", "78.9", "", "57.7", "", "2", "", "", "102", "1", "2", "24", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.3", "96.9", "", "", "", "", "95.1"]} +{"pcdb_id": 18610, "brand_name": "Biasi", "model_name": "ADVANCE 18OV", "model_qualifier": "41-583-36", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 78.9, "comparative_hot_water_efficiency_pct": 57.6, "output_kw_max": 20.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018610", "000208", "0", "2019/Jun/12 12:01", "Biasi (UK)", "Biasi", "ADVANCE 18OV", "41-583-36", "", "2019", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "20.3", "20.3", "", "", "87.9", "78.9", "", "57.6", "", "2", "", "", "102", "1", "2", "36", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.0", "96.9", "", "", "", "", "95.1"]} +{"pcdb_id": 18611, "brand_name": "Biasi", "model_name": "ADVANCE 24OV", "model_qualifier": "41-583-37", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 24.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018611", "000208", "0", "2019/Jun/12 12:02", "Biasi (UK)", "Biasi", "ADVANCE 24OV", "41-583-37", "", "2019", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24.4", "24.4", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "40", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "96.8", "", "", "", "", "95.1"]} +{"pcdb_id": 18612, "brand_name": "Firebird", "model_name": "Envirogreen Heatpac Condensing Boiler", "model_qualifier": "58kW", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 80.6, "comparative_hot_water_efficiency_pct": 58.9, "output_kw_max": 58.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018612", "000047", "0", "2019/Oct/21 15:47", "Firebird Heating Solutions Ltd", "Firebird", "Envirogreen Heatpac Condensing Boiler", "58kW", "", "2019", "current", "4", "1", "2", "1", "0", "", "", "2", "2", "1", "58.0", "58.0", "", "", "88.4", "80.6", "", "58.9", "", "2", "", "", "201", "1", "1", "166", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.2", "95.8", "", "", "", "", "94.9"]} +{"pcdb_id": 18613, "brand_name": "Firebird", "model_name": "Envirogreen Kitchen Condensing Boiler", "model_qualifier": "58kW", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 80.6, "comparative_hot_water_efficiency_pct": 58.9, "output_kw_max": 58.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018613", "000047", "0", "2019/Oct/21 15:47", "Firebird Heating Solutions Ltd", "Firebird", "Envirogreen Kitchen Condensing Boiler", "58kW", "", "2019", "current", "4", "1", "1", "1", "0", "", "", "2", "2", "1", "58.0", "58.0", "", "", "88.4", "80.6", "", "58.9", "", "2", "", "", "201", "1", "1", "166", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.2", "95.8", "", "", "", "", "94.9"]} +{"pcdb_id": 18614, "brand_name": "Firebird", "model_name": "Envirogreen Popular Condensing Boiler", "model_qualifier": "58kW", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 80.6, "comparative_hot_water_efficiency_pct": 58.9, "output_kw_max": 58.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018614", "000047", "0", "2019/Oct/21 15:48", "Firebird Heating Solutions Ltd", "Firebird", "Envirogreen Popular Condensing Boiler", "58kW", "", "2019", "current", "4", "1", "1", "1", "0", "", "", "2", "2", "1", "58.0", "58.0", "", "", "88.4", "80.6", "", "58.9", "", "2", "", "", "201", "1", "1", "166", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.2", "95.8", "", "", "", "", "94.9"]} +{"pcdb_id": 18615, "brand_name": "Ariston", "model_name": "CLAS ONE R 24", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 21.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018615", "000080", "0", "2020/Sep/08 16:36", "Ariston Thermo S.p.A", "Ariston", "CLAS ONE R 24", "", "3301466", "2019", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "21.5", "21.5", "", "", "88.8", "79.8", "", "58.3", "", "2", "", "", "102", "1", "2", "30", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "98.9", "", "", "", "", "96.8"]} +{"pcdb_id": 18616, "brand_name": "Worcester", "model_name": "Greenstar 8000 Life", "model_qualifier": "GR8300iW 30 C NG", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 88.2, "comparative_hot_water_efficiency_pct": 73.5, "output_kw_max": 29.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.001, "loss_factor_f1_kwh_per_day": 1.05319, "loss_factor_f2_kwh_per_day": 1.02566, "rejected_factor_f3_per_litre": 0.0, "raw": ["018616", "000035", "0", "2020/Jul/27 17:33", "Bosch Thermotechnology", "Worcester", "Greenstar 8000 Life", "GR8300iW 30 C NG", "47-800-18", "2018", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "29.5", "29.5", "", "", "88.8", "88.2", "", "73.5", "", "2", "", "", "104", "1", "2", "67", "1", "0", "", "", "", "0", "", "", "", "", "2", "7.168", "0.098", "0.001", "1.05319", "13.007", "0.118", "0.001", "1.02566", "0.0", "", "", "", "8325", "", "", "", "", "", "", "", "", "88.3", "98.7", "", "", "", "", "96.7"]} +{"pcdb_id": 18617, "brand_name": "Worcester", "model_name": "Greenstar 8000 Life", "model_qualifier": "GR8300iW 30 R NG", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 29.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018617", "000035", "0", "2019/Aug/22 14:16", "Bosch Thermotechnology", "Worcester", "Greenstar 8000 Life", "GR8300iW 30 R NG", "41-406-98", "2018", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "29.5", "29.5", "", "", "88.8", "79.8", "", "58.3", "", "2", "", "", "102", "1", "2", "67", "1", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0305", "", "", "", "", "", "", "", "", "88.3", "98.7", "", "", "", "", "96.7"]} +{"pcdb_id": 18618, "brand_name": "Worcester", "model_name": "Greenstar 8000 Life", "model_qualifier": "GR8300iW 30 S NG", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 29.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018618", "000035", "0", "2019/Aug/22 14:18", "Bosch Thermotechnology", "Worcester", "Greenstar 8000 Life", "GR8300iW 30 S NG", "41-406-91", "2018", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "29.5", "29.5", "", "", "88.8", "79.8", "", "58.3", "", "2", "", "", "102", "1", "2", "67", "1", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "8325", "", "", "", "", "", "", "", "", "88.3", "98.7", "", "", "", "", "96.7"]} +{"pcdb_id": 18619, "brand_name": "Worcester", "model_name": "Greenstar 8000 Life", "model_qualifier": "GR8300iW 35 C NG", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 88.2, "comparative_hot_water_efficiency_pct": 75.1, "output_kw_max": 33.7, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.0045, "loss_factor_f1_kwh_per_day": 0.84809, "loss_factor_f2_kwh_per_day": 0.85555, "rejected_factor_f3_per_litre": 4e-05, "raw": ["018619", "000035", "0", "2020/Jul/27 17:39", "Bosch Thermotechnology", "Worcester", "Greenstar 8000 Life", "GR8300iW 35 C NG", "47-800-17", "2018", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "33.7", "33.7", "", "", "88.6", "88.2", "", "75.1", "", "2", "", "", "104", "1", "2", "48", "1", "0", "", "", "", "0", "", "", "", "", "2", "7.012", "0.103", "0.0045", "0.84809", "12.813", "0.118", "0.0005", "0.85555", "0.00004", "", "", "", "8325", "", "", "", "", "", "", "", "", "86.9", "98.8", "", "", "", "", "96.6"]} +{"pcdb_id": 18620, "brand_name": "Worcester", "model_name": "Greenstar 8000 Life", "model_qualifier": "GR8300iW 35 R NG", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 33.7, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018620", "000035", "0", "2019/Aug/22 14:19", "Bosch Thermotechnology", "Worcester", "Greenstar 8000 Life", "GR8300iW 35 R NG", "41-406-97", "2018", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "33.7", "33.7", "", "", "88.6", "79.6", "", "58.2", "", "2", "", "", "102", "1", "2", "48", "1", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0305", "", "", "", "", "", "", "", "", "86.9", "98.8", "", "", "", "", "96.6"]} +{"pcdb_id": 18621, "brand_name": "Worcester", "model_name": "Greenstar 8000 Life", "model_qualifier": "GR8300iW 35 S NG", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 33.7, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018621", "000035", "0", "2019/Aug/21 17:19", "Bosch Thermotechnology", "Worcester", "Greenstar 8000 Life", "GR8300iW 35 S NG", "41-406-90", "2018", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "33.7", "33.7", "", "", "88.6", "79.6", "", "58.2", "", "2", "", "", "102", "1", "2", "48", "1", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "8325", "", "", "", "", "", "", "", "", "86.9", "98.8", "", "", "", "", "96.6"]} +{"pcdb_id": 18622, "brand_name": "Worcester", "model_name": "Greenstar 8000 Life", "model_qualifier": "GR8300iW 40 C NG", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 88.2, "comparative_hot_water_efficiency_pct": 73.4, "output_kw_max": 33.7, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.001, "loss_factor_f1_kwh_per_day": 1.03647, "loss_factor_f2_kwh_per_day": 1.03238, "rejected_factor_f3_per_litre": 1e-05, "raw": ["018622", "000035", "0", "2020/Jul/27 17:46", "Bosch Thermotechnology", "Worcester", "Greenstar 8000 Life", "GR8300iW 40 C NG", "47-800-16", "2018", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "33.7", "33.7", "", "", "88.7", "88.2", "", "73.4", "", "2", "", "", "104", "1", "2", "48", "1", "0", "", "", "", "0", "", "", "", "", "2", "7.175", "0.107", "0.001", "1.03647", "13.05", "0.126", "0.0005", "1.03238", "0.00001", "", "", "", "8325", "", "", "", "", "", "", "", "", "87.4", "98.7", "", "", "", "", "96.6"]} +{"pcdb_id": 18623, "brand_name": "Worcester", "model_name": "Greenstar 8000 Life", "model_qualifier": "GR8300iW 40 R NG", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 40.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018623", "000035", "0", "2019/Oct/10 16:30", "Bosch Thermotechnology", "Worcester", "Greenstar 8000 Life", "GR8300iW 40 R NG", "41-406-96", "2018", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "40", "40", "", "", "88.7", "79.7", "", "58.2", "", "2", "", "", "102", "1", "2", "75", "1", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0305", "", "", "", "", "", "", "", "", "87.4", "98.7", "", "", "", "", "96.6"]} +{"pcdb_id": 18624, "brand_name": "Worcester", "model_name": "Greenstar 8000 Life", "model_qualifier": "GR8300IW 45 C NG", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 88.2, "comparative_hot_water_efficiency_pct": 74.1, "output_kw_max": 33.7, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.0075, "loss_factor_f1_kwh_per_day": 0.96653, "loss_factor_f2_kwh_per_day": 0.92531, "rejected_factor_f3_per_litre": 4e-05, "raw": ["018624", "000035", "0", "2020/Jul/27 17:54", "Bosch Thermotechnology", "Worcester", "Greenstar 8000 Life", "GR8300IW 45 C NG", "47-800-15", "2018", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "33.7", "33.7", "", "", "88.9", "88.2", "", "74.1", "", "2", "", "", "104", "1", "2", "48", "1", "0", "", "", "", "0", "", "", "", "", "2", "7.103", "0.104", "0.0075", "0.96653", "12.953", "0.121", "0.0035", "0.92531", "0.00004", "", "", "", "8325", "", "", "", "", "", "", "", "", "88.8", "98.8", "", "", "", "", "96.9"]} +{"pcdb_id": 18625, "brand_name": "Worcester", "model_name": "Greenstar 8000 Life", "model_qualifier": "GR8300iW 45 R NG", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 42.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018625", "000035", "0", "2020/Jan/15 14:16", "Bosch Thermotechnology", "Worcester", "Greenstar 8000 Life", "GR8300iW 45 R NG", "41-406-95", "2018", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "42.6", "42.6", "", "", "89.2", "80.2", "", "58.6", "", "2", "", "", "102", "1", "2", "84", "1", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0305", "", "", "", "", "", "", "", "", "88.8", "99.5", "", "", "", "", "97.5"]} +{"pcdb_id": 18626, "brand_name": "Worcester", "model_name": "Greenstar 8000 Life", "model_qualifier": "GR8300iW 50 C NG", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 88.2, "comparative_hot_water_efficiency_pct": 74.2, "output_kw_max": 33.7, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.001, "loss_factor_f1_kwh_per_day": 0.9997, "loss_factor_f2_kwh_per_day": 0.95851, "rejected_factor_f3_per_litre": 0.0, "raw": ["018626", "000035", "0", "2020/Jul/27 17:56", "Bosch Thermotechnology", "Worcester", "Greenstar 8000 Life", "GR8300iW 50 C NG", "47-800-14", "2018", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "33.7", "33.7", "", "", "88.9", "88.2", "", "74.2", "", "2", "", "", "104", "1", "2", "48", "1", "0", "", "", "", "0", "", "", "", "", "2", "7.098", "0.101", "0.001", "0.9997", "12.909", "0.121", "0.001", "0.95851", "0.0", "", "", "", "8325", "", "", "", "", "", "", "", "", "88.8", "98.8", "", "", "", "", "96.9"]} +{"pcdb_id": 18627, "brand_name": "Worcester", "model_name": "Greenstar 8000 Life", "model_qualifier": "GR8300iW 50 R NG", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 47.9, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018627", "000035", "0", "2020/Jan/15 14:16", "Bosch Thermotechnology", "Worcester", "Greenstar 8000 Life", "GR8300iW 50 R NG", "41-406-94", "2018", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "47.9", "47.9", "", "", "89.0", "80.0", "", "58.5", "", "2", "", "", "102", "1", "2", "84", "1", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0305", "", "", "", "", "", "", "", "", "88.6", "99.2", "", "", "", "", "97.2"]} +{"pcdb_id": 18628, "brand_name": "BoilerPlan", "model_name": "BP31 HE", "model_qualifier": "", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 55.9, "output_kw_max": 24.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018628", "000313", "0", "2020/Jun/24 10:37", "Boiler Plan (UK) Ltd", "BoilerPlan", "BP31 HE", "", "", "2019", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.3", "24.3", "", "", "88.0", "79.4", "", "55.9", "", "2", "", "", "104", "1", "2", "36", "5", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0015", "", "", "", "", "", "", "", "", "87.5", "97.1", "", "", "", "", "95.3"]} +{"pcdb_id": 18629, "brand_name": "E.C.A.", "model_name": "PROTEUS PREMIX", "model_qualifier": "24 HCH NG ERP UK", "winter_efficiency_pct": 87.7, "summer_efficiency_pct": 78.7, "comparative_hot_water_efficiency_pct": 57.5, "output_kw_max": 24.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018629", "000248", "0", "2020/Feb/18 11:24", "Emas Makina Sanayi", "E.C.A.", "PROTEUS PREMIX", "24 HCH NG ERP UK", "41-814-01", "2017", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24.5", "24.5", "", "", "87.7", "78.7", "", "57.5", "", "2", "", "", "102", "1", "2", "40", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "96.0", "", "", "", "", "94.5"]} +{"pcdb_id": 18630, "brand_name": "E.C.A.", "model_name": "PROTEUS PREMIX", "model_qualifier": "24 HM NG ERP UK", "winter_efficiency_pct": 87.7, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 55.6, "output_kw_max": 24.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018630", "000248", "0", "2020/Feb/18 11:25", "Emas Makina Sanayi", "E.C.A.", "PROTEUS PREMIX", "24 HM NG ERP UK", "47-814-01", "2017", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.5", "24.5", "", "", "87.7", "79.1", "", "55.6", "", "2", "", "", "104", "1", "2", "40", "5", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "96.0", "", "", "", "", "94.5"]} +{"pcdb_id": 18631, "brand_name": "E.C.A.", "model_name": "PROTEUS PREMIX", "model_qualifier": "24 HST NG ERP UK", "winter_efficiency_pct": 87.7, "summer_efficiency_pct": 78.7, "comparative_hot_water_efficiency_pct": 57.5, "output_kw_max": 24.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018631", "000248", "0", "2020/Feb/18 11:25", "Emas Makina Sanayi", "E.C.A.", "PROTEUS PREMIX", "24 HST NG ERP UK", "41-814-05", "2018", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24.5", "24.5", "", "", "87.7", "78.7", "", "57.5", "", "2", "", "", "102", "1", "2", "40", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "96.0", "", "", "", "", "94.5"]} +{"pcdb_id": 18632, "brand_name": "E.C.A.", "model_name": "PROTEUS PREMIX", "model_qualifier": "28 HCH NG ERP UK", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 28.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018632", "000248", "0", "2020/Feb/18 11:25", "Emas Makina Sanayi", "E.C.A.", "PROTEUS PREMIX", "28 HCH NG ERP UK", "41-814-02", "2017", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "28.0", "28.0", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "51", "4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "96.9", "", "", "", "", "95.2"]} +{"pcdb_id": 18633, "brand_name": "E.C.A.", "model_name": "PROTEUS PREMIX", "model_qualifier": "28 HM NG ERP UK", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 55.9, "output_kw_max": 28.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018633", "000248", "0", "2020/Feb/18 11:25", "Emas Makina Sanayi", "E.C.A.", "PROTEUS PREMIX", "28 HM NG ERP UK", "47-814-02", "2017", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28.0", "28.0", "", "", "88.0", "79.4", "", "55.9", "", "2", "", "", "104", "1", "2", "51", "4", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "96.9", "", "", "", "", "95.2"]} +{"pcdb_id": 18634, "brand_name": "E.C.A.", "model_name": "PROTEUS PREMIX", "model_qualifier": "28 HST NG ERP UK", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 28.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018634", "000248", "0", "2020/Feb/18 11:26", "Emas Makina Sanayi", "E.C.A.", "PROTEUS PREMIX", "28 HST NG ERP UK", "41-814-06", "2017", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "28.0", "28.0", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "51", "4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "96.9", "", "", "", "", "95.2"]} +{"pcdb_id": 18635, "brand_name": "E.C.A.", "model_name": "PROTEUS PREMIX", "model_qualifier": "30 HCH NG ERP UK", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 30.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018635", "000248", "0", "2020/Feb/18 11:26", "Emas Makina Sanayi", "E.C.A.", "PROTEUS PREMIX", "30 HCH NG ERP UK", "41-814-03", "2017", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "30.0", "30.0", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "56", "4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "96.8", "", "", "", "", "95.1"]} +{"pcdb_id": 18636, "brand_name": "E.C.A.", "model_name": "PROTEUS PREMIX", "model_qualifier": "30 HM NG ERP UK", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 55.8, "output_kw_max": 30.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018636", "000248", "0", "2020/Feb/18 11:26", "Emas Makina Sanayi", "E.C.A.", "PROTEUS PREMIX", "30 HM NG ERP UK", "47-814-03", "2017", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "30.0", "30.0", "", "", "88.0", "79.4", "", "55.8", "", "2", "", "", "104", "1", "2", "56", "4", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "96.8", "", "", "", "", "95.1"]} +{"pcdb_id": 18637, "brand_name": "E.C.A.", "model_name": "PROTEUS PREMIX", "model_qualifier": "30 HST NG ERP UK", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 30.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018637", "000248", "0", "2020/Feb/18 11:27", "Emas Makina Sanayi", "E.C.A.", "PROTEUS PREMIX", "30 HST NG ERP UK", "41-814-07", "2017", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "30.0", "30.0", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "56", "4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "96.8", "", "", "", "", "95.1"]} +{"pcdb_id": 18638, "brand_name": "E.C.A.", "model_name": "PROTEUS PREMIX", "model_qualifier": "35 HCH NG ERP UK", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 78.9, "comparative_hot_water_efficiency_pct": 57.6, "output_kw_max": 35.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018638", "000248", "0", "2020/Feb/18 11:27", "Emas Makina Sanayi", "E.C.A.", "PROTEUS PREMIX", "35 HCH NG ERP UK", "41-814-04", "2017", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "35.0", "35.0", "", "", "87.9", "78.9", "", "57.6", "", "2", "", "", "102", "1", "2", "66", "4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "96.5", "", "", "", "", "94.9"]} +{"pcdb_id": 18639, "brand_name": "E.C.A.", "model_name": "PROTEUS PREMIX", "model_qualifier": "35 HM NG ERP UK", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 55.7, "output_kw_max": 35.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018639", "000248", "0", "2020/Feb/18 11:27", "Emas Makina Sanayi", "E.C.A.", "PROTEUS PREMIX", "35 HM NG ERP UK", "47-814-04", "2017", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "35.0", "35.0", "", "", "87.9", "79.3", "", "55.7", "", "2", "", "", "104", "1", "2", "66", "4", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "96.5", "", "", "", "", "94.9"]} +{"pcdb_id": 18640, "brand_name": "E.C.A.", "model_name": "PROTEUS PREMIX", "model_qualifier": "35 HST NG ERP UK", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 78.9, "comparative_hot_water_efficiency_pct": 57.6, "output_kw_max": 35.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018640", "000248", "0", "2020/Feb/18 11:28", "Emas Makina Sanayi", "E.C.A.", "PROTEUS PREMIX", "35 HST NG ERP UK", "41-814-08", "2017", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "35.0", "35.0", "", "", "87.9", "78.9", "", "57.6", "", "2", "", "", "102", "1", "2", "66", "4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "96.5", "", "", "", "", "94.9"]} +{"pcdb_id": 18641, "brand_name": "ATAG", "model_name": "I24S", "model_qualifier": "", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 21.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018641", "000299", "0", "2020/Mar/19 09:44", "ATAG Verwarming Nederland", "ATAG", "I24S", "", "", "2019", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "21.2", "21.2", "", "", "89.1", "80.1", "", "58.5", "", "2", "", "", "102", "1", "2", "74", "4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "88.3", "99.4", "", "", "", "", "97.3"]} +{"pcdb_id": 18642, "brand_name": "ATAG", "model_name": "I18S", "model_qualifier": "", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 15.9, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018642", "000299", "0", "2020/Apr/15 08:21", "ATAG Verwarming Nederland", "ATAG", "I18S", "", "", "2019", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "15.9", "15.9", "", "", "89.1", "80.1", "", "58.5", "", "2", "", "", "102", "1", "2", "74", "4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "88.6", "99.4", "", "", "", "", "97.3"]} +{"pcdb_id": 18643, "brand_name": "ATAG", "model_name": "IC Eonomiser 35 Plus", "model_qualifier": "", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 98.9, "comparative_hot_water_efficiency_pct": 83.6, "output_kw_max": 28.3, "final_year_of_manufacture": null, "subsidiary_type": 1, "store_type": 0, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.0035, "loss_factor_f1_kwh_per_day": 0.20583, "loss_factor_f2_kwh_per_day": 0.90833, "rejected_factor_f3_per_litre": 2e-05, "raw": ["018643", "000299", "0", "2020/Apr/09 16:17", "ATAG Verwarming Nederland", "ATAG", "IC Eonomiser 35 Plus", "", "", "2019", "current", "1", "2", "1", "2", "1", "", "", "2", "2", "2", "28.3", "28.3", "", "", "89.1", "98.9", "", "83.6", "", "2", "", "", "104", "1", "2", "74", "4", "0", "", "", "", "0", "", "", "", "", "2", "6.297", "0.154", "0.0035", "0.20583", "11.494", "0.174", "0.002", "0.90833", "0.00002", "", "", "", "0025", "", "", "", "", "", "", "", "", "88.6", "99.5", "", "", "", "", "97.4"]} +{"pcdb_id": 18644, "brand_name": "ATAG", "model_name": "I18R", "model_qualifier": "", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 15.9, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018644", "000299", "0", "2020/Mar/19 09:43", "ATAG Verwarming Nederland", "ATAG", "I18R", "", "", "2019", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "15.9", "15.9", "", "", "89.1", "80.1", "", "58.5", "", "2", "", "", "102", "1", "2", "74", "4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "88.6", "99.4", "", "", "", "", "97.3"]} +{"pcdb_id": 18645, "brand_name": "ATAG", "model_name": "I40S", "model_qualifier": "", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 35.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018645", "000299", "0", "2020/Mar/19 09:20", "ATAG Verwarming Nederland", "ATAG", "I40S", "", "", "2019", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "35.3", "35.3", "", "", "89.1", "80.1", "", "58.5", "", "2", "", "", "102", "1", "2", "74", "4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "88.4", "99.4", "", "", "", "", "97.3"]} +{"pcdb_id": 18648, "brand_name": "ATAG", "model_name": "IC Economiser 27 Plus", "model_qualifier": "", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 98.9, "comparative_hot_water_efficiency_pct": 85.4, "output_kw_max": 23.2, "final_year_of_manufacture": null, "subsidiary_type": 1, "store_type": 0, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.012, "loss_factor_f1_kwh_per_day": 0.02572, "loss_factor_f2_kwh_per_day": 0.71988, "rejected_factor_f3_per_litre": 6e-05, "raw": ["018648", "000299", "0", "2020/Apr/09 16:16", "ATAG Verwarming Nederland", "ATAG", "IC Economiser 27 Plus", "", "", "2019", "current", "1", "2", "1", "2", "1", "", "", "2", "2", "2", "23.2", "23.2", "", "", "89.1", "98.9", "", "85.4", "", "2", "", "", "104", "1", "2", "74", "4", "0", "", "", "", "0", "", "", "", "", "2", "6.168", "0.153", "0.012", "0.02572", "11.449", "0.17", "0.006", "0.71988", "0.00006", "", "", "", "0025", "", "", "", "", "", "", "", "", "88.3", "99.4", "", "", "", "", "97.3"]} +{"pcdb_id": 18649, "brand_name": "ATAG", "model_name": "IC Economiser 39 Plus", "model_qualifier": "", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 98.9, "comparative_hot_water_efficiency_pct": 83.6, "output_kw_max": 28.3, "final_year_of_manufacture": null, "subsidiary_type": 1, "store_type": 0, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.0035, "loss_factor_f1_kwh_per_day": 0.20583, "loss_factor_f2_kwh_per_day": 0.90833, "rejected_factor_f3_per_litre": 2e-05, "raw": ["018649", "000299", "0", "2020/Apr/09 16:15", "ATAG Verwarming Nederland", "ATAG", "IC Economiser 39 Plus", "", "", "2019", "current", "1", "2", "1", "2", "1", "", "", "2", "2", "2", "28.3", "28.3", "", "", "89.1", "98.9", "", "83.6", "", "2", "", "", "104", "1", "2", "74", "4", "0", "", "", "", "0", "", "", "", "", "2", "6.297", "0.154", "0.0035", "0.20583", "11.494", "0.174", "0.002", "0.90833", "0.00002", "", "", "", "0025", "", "", "", "", "", "", "", "", "88.6", "99.5", "", "", "", "", "97.4"]} +{"pcdb_id": 18650, "brand_name": "ATAG", "model_name": "i40C", "model_qualifier": "", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 88.2, "comparative_hot_water_efficiency_pct": 76.5, "output_kw_max": 28.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.0008, "loss_factor_f1_kwh_per_day": 0.78828, "loss_factor_f2_kwh_per_day": 0.75508, "rejected_factor_f3_per_litre": 0.0, "raw": ["018650", "000299", "0", "2020/Apr/09 16:15", "ATAG Verwarming Nederland", "ATAG", "i40C", "", "", "2019", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28.3", "28.3", "", "", "89.1", "88.2", "", "76.5", "", "2", "", "", "104", "1", "2", "74", "4", "0", "", "", "", "0", "", "", "", "", "2", "6.885", "0.179", "0.0008", "0.78828", "12.646", "0.196", "0.0004", "0.75508", "0.0", "", "", "", "0025", "", "", "", "", "", "", "", "", "88.6", "99.5", "", "", "", "", "97.4"]} +{"pcdb_id": 18651, "brand_name": "ATAG", "model_name": "i36C", "model_qualifier": "", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 86.9, "comparative_hot_water_efficiency_pct": 76.6, "output_kw_max": 28.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0008, "loss_factor_f1_kwh_per_day": 0.77574, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018651", "000299", "0", "2020/Mar/19 09:46", "ATAG Verwarming Nederland", "ATAG", "i36C", "", "", "2019", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28.3", "28.3", "", "", "89.1", "86.9", "", "76.6", "", "2", "", "", "104", "1", "2", "74", "4", "0", "", "", "", "0", "", "", "", "", "1", "6.872", "0.182", "0.0008", "0.77574", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "88.6", "99.5", "", "", "", "", "97.4"]} +{"pcdb_id": 18652, "brand_name": "ATAG", "model_name": "I40R", "model_qualifier": "", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 35.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018652", "000299", "0", "2020/Mar/19 09:46", "ATAG Verwarming Nederland", "ATAG", "I40R", "", "", "2019", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "35.3", "35.3", "", "", "89.1", "80.1", "", "58.5", "", "2", "", "", "102", "1", "2", "74", "4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "88.4", "99.4", "", "", "", "", "97.3"]} +{"pcdb_id": 18653, "brand_name": "ATAG", "model_name": "i28C", "model_qualifier": "", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 88.2, "comparative_hot_water_efficiency_pct": 77.4, "output_kw_max": 21.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.0008, "loss_factor_f1_kwh_per_day": 0.70169, "loss_factor_f2_kwh_per_day": 0.67557, "rejected_factor_f3_per_litre": 0.0, "raw": ["018653", "000299", "0", "2020/Apr/09 16:11", "ATAG Verwarming Nederland", "ATAG", "i28C", "", "", "2019", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "21.2", "21.2", "", "", "89.1", "88.2", "", "77.4", "", "2", "", "", "104", "1", "2", "74", "4", "0", "", "", "", "0", "", "", "", "", "2", "6.802", "0.169", "0.0008", "0.70169", "12.464", "0.178", "0.0004", "0.67557", "0.0", "", "", "", "0025", "", "", "", "", "", "", "", "", "88.3", "99.4", "", "", "", "", "97.3"]} +{"pcdb_id": 18654, "brand_name": "ATAG", "model_name": "I24R", "model_qualifier": "", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 21.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018654", "000299", "0", "2020/Mar/19 09:45", "ATAG Verwarming Nederland", "ATAG", "I24R", "", "", "2019", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "21.2", "21.2", "", "", "89.1", "80.1", "", "58.5", "", "2", "", "", "102", "1", "2", "74", "4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "88.3", "99.4", "", "", "", "", "97.3"]} +{"pcdb_id": 18655, "brand_name": "ATAG", "model_name": "I32S", "model_qualifier": "", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 28.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018655", "000299", "0", "2020/Mar/19 09:45", "ATAG Verwarming Nederland", "ATAG", "I32S", "", "", "2019", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "28.3", "28.3", "", "", "89.1", "80.1", "", "58.5", "", "2", "", "", "102", "1", "2", "74", "4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "88.6", "99.5", "", "", "", "", "97.4"]} +{"pcdb_id": 18656, "brand_name": "ATAG", "model_name": "I32R", "model_qualifier": "", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 28.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018656", "000299", "0", "2020/Mar/19 09:45", "ATAG Verwarming Nederland", "ATAG", "I32R", "", "", "2019", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "28.3", "28.3", "", "", "89.1", "80.1", "", "58.5", "", "2", "", "", "102", "1", "2", "74", "4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "88.6", "99.5", "", "", "", "", "97.4"]} +{"pcdb_id": 18657, "brand_name": "ATAG", "model_name": "I15S", "model_qualifier": "", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 13.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018657", "000299", "0", "2020/Mar/19 09:44", "ATAG Verwarming Nederland", "ATAG", "I15S", "", "", "2019", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "13.3", "13.3", "", "", "89.1", "80.1", "", "58.5", "", "2", "", "", "102", "1", "2", "74", "4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "88.8", "99.2", "", "", "", "", "97.2"]} +{"pcdb_id": 18658, "brand_name": "ATAG", "model_name": "i24C", "model_qualifier": "", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 88.2, "comparative_hot_water_efficiency_pct": 77.4, "output_kw_max": 21.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.0008, "loss_factor_f1_kwh_per_day": 0.70546, "loss_factor_f2_kwh_per_day": 0.67932, "rejected_factor_f3_per_litre": 0.0, "raw": ["018658", "000299", "0", "2020/Apr/09 16:10", "ATAG Verwarming Nederland", "ATAG", "i24C", "", "", "2019", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "21.2", "21.2", "", "", "89.1", "88.2", "", "77.4", "", "2", "", "", "104", "1", "2", "74", "4", "0", "", "", "", "0", "", "", "", "", "2", "6.806", "0.168", "0.0008", "0.70546", "12.475", "0.188", "0.0004", "0.67932", "0.0", "", "", "", "0025", "", "", "", "", "", "", "", "", "88.3", "99.4", "", "", "", "", "97.3"]} +{"pcdb_id": 18659, "brand_name": "ATAG", "model_name": "I15R", "model_qualifier": "", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 13.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018659", "000299", "0", "2020/Mar/19 09:44", "ATAG Verwarming Nederland", "ATAG", "I15R", "", "", "2019", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "13.3", "13.3", "", "", "89.1", "80.1", "", "58.5", "", "2", "", "", "102", "1", "2", "74", "4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "88.8", "99.2", "", "", "", "", "97.2"]} +{"pcdb_id": 18660, "brand_name": "Warmflow", "model_name": "B26", "model_qualifier": "Agentis Boiler House 26", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 80.6, "comparative_hot_water_efficiency_pct": 58.9, "output_kw_max": 27.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018660", "000063", "0", "2019/Sep/19 13:18", "Warmflow Engineering", "Warmflow", "B26", "Agentis Boiler House 26", "", "2019", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "21", "27", "", "", "88.4", "80.6", "", "58.9", "", "2", "", "", "201", "1", "1", " 146", " 0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.5", "95.6", "", "", "", "", "94.8"]} +{"pcdb_id": 18661, "brand_name": "Warmflow", "model_name": "E26", "model_qualifier": "Agentis External 26", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 80.6, "comparative_hot_water_efficiency_pct": 58.9, "output_kw_max": 27.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018661", "000063", "0", "2019/Sep/19 13:18", "Warmflow Engineering", "Warmflow", "E26", "Agentis External 26", "", "2019", "current", "4", "1", "2", "1", "0", "", "", "2", "3", "2", "21.0000", "27.0000", "", "", "88.4", "80.6", "", "58.9", "", "2", "", "", "201", "1", "1", " 146", " 0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.5", "95.6", "", "", "", "", "94.8"]} +{"pcdb_id": 18662, "brand_name": "Warmflow", "model_name": "I26", "model_qualifier": "Agentis Internal 26", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 80.6, "comparative_hot_water_efficiency_pct": 58.9, "output_kw_max": 27.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018662", "000063", "0", "2019/Sep/19 13:17", "Warmflow Engineering", "Warmflow", "I26", "Agentis Internal 26", "", "2019", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "21.0000", "27.0000", "", "", "88.4", "80.6", "", "58.9", "", "2", "", "", "201", "1", "1", " 146", " 0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.5", "95.6", "", "", "", "", "94.8"]} +{"pcdb_id": 18663, "brand_name": "Alpha", "model_name": "E-Tec", "model_qualifier": "25R", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 24.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018663", "000001", "0", "2020/Jan/06 15:33", "Alpha Therm", "Alpha", "E-Tec", "25R", "3.028465", "2018", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24", "24", "", "", "88.3", "79.3", "", "57.9", "", "2", "", "", "102", "1", "2", " 27", " 6", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "1005", "", "", "", "", "", "", "", "", "88.1", "97.6", "", "", "", "", "95.8"]} +{"pcdb_id": 18665, "brand_name": "HRM", "model_name": "X1", "model_qualifier": "LOW NOX CONDENSING 12 - 16 Kw", "winter_efficiency_pct": 86.6, "summer_efficiency_pct": 78.8, "comparative_hot_water_efficiency_pct": 57.6, "output_kw_max": 16.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018665", "000098", "0", "2019/Sep/11 13:39", "HRM Boilers", "HRM", "X1", "LOW NOX CONDENSING 12 - 16 Kw", "", "2018", "current", "4", "2", "2", "1", "0", "", "", "2", "2", "2", "12", "16", "", "", "86.6", "78.8", "", "57.6", "", "2", "", "", "201", "1", "1", " 138", " 0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "89.4", "91.9", "", "", "", "", "91.4"]} +{"pcdb_id": 18666, "brand_name": "HRM", "model_name": "X 1 SYSTEM", "model_qualifier": "LOW NOX CONDENSING 12 - 16 Kw", "winter_efficiency_pct": 86.6, "summer_efficiency_pct": 78.8, "comparative_hot_water_efficiency_pct": 57.6, "output_kw_max": 16.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018666", "000098", "0", "2019/Sep/11 13:38", "HRM Boilers", "HRM", "X 1 SYSTEM", "LOW NOX CONDENSING 12 - 16 Kw", "", "2018", "current", "4", "2", "2", "1", "0", "", "", "2", "2", "2", "12", "16", "", "", "86.6", "78.8", "", "57.6", "", "2", "", "", "201", "1", "1", " 138", " 0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "89.4", "91.9", "", "", "", "", "91.4"]} +{"pcdb_id": 18667, "brand_name": "Warmflow", "model_name": "E21C", "model_qualifier": "AGENTIS EXTERNAL COMBI 21", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 90.0, "comparative_hot_water_efficiency_pct": 64.5, "output_kw_max": 21.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 1, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0, "loss_factor_f1_kwh_per_day": 2.30726, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018667", "000063", "0", "2020/Jan/22 13:11", "Warmflow Engineering", "Warmflow", "E21C", "AGENTIS EXTERNAL COMBI 21", "", "2019", "current", "4", "1", "2", "2", "0", "", "", "2", "3", "2", "15.0000", "21.0000", "", "", "88.7", "90.0", "", "64.5", "", "2", "", "", "203", "1", "1", "163", "3", "1", "2", "0", "38", "0", "20", "4", "58", "", "1", "8.487", "0.117", "0.0", "2.30726", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.1", "96.5", "", "", "", "", "95.5"]} +{"pcdb_id": 18668, "brand_name": "Warmflow", "model_name": "E26C", "model_qualifier": "AGENTIS EXTERNAL COMBI 26", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 90.0, "comparative_hot_water_efficiency_pct": 62.6, "output_kw_max": 27.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 1, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0, "loss_factor_f1_kwh_per_day": 2.56085, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018668", "000063", "0", "2020/Jan/22 13:11", "Warmflow Engineering", "Warmflow", "E26C", "AGENTIS EXTERNAL COMBI 26", "", "2019", "current", "4", "1", "2", "2", "0", "", "", "2", "3", "2", "21.0000", "27.0000", "", "", "88.2", "90.0", "", "62.6", "", "2", "", "", "203", "1", "1", "140", "3", "1", "2", "0", "38", "0", "20", "4", "58", "", "1", "8.751", "0.108", "0.0", "2.56085", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.1", "95.1", "", "", "", "", "94.3"]} +{"pcdb_id": 18669, "brand_name": "Warmflow", "model_name": "E33C", "model_qualifier": "AGENTIS EXTERNAL COMBI 33", "winter_efficiency_pct": 87.4, "summer_efficiency_pct": 89.9, "comparative_hot_water_efficiency_pct": 57.3, "output_kw_max": 32.7, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 1, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0, "loss_factor_f1_kwh_per_day": 3.31777, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018669", "000063", "0", "2020/Jan/22 13:11", "Warmflow Engineering", "Warmflow", "E33C", "AGENTIS EXTERNAL COMBI 33", "", "2019", "current", "4", "1", "2", "2", "0", "", "", "2", "3", "2", "27", "32.7", "", "", "87.4", "89.9", "", "57.3", "", "2", "", "", "203", "1", "1", "148", "3", "1", "2", "0", "38", "0", "20", "4", "58", "", "1", "9.552", "0.088", "0.0", "3.31777", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.7", "93.3", "", "", "", "", "92.8"]} +{"pcdb_id": 18670, "brand_name": "Warmflow", "model_name": "I21C", "model_qualifier": "AGENTIS INTERNAL COMBI 21", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 90.0, "comparative_hot_water_efficiency_pct": 64.5, "output_kw_max": 21.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 1, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0, "loss_factor_f1_kwh_per_day": 2.30726, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018670", "000063", "0", "2020/Jan/22 13:11", "Warmflow Engineering", "Warmflow", "I21C", "AGENTIS INTERNAL COMBI 21", "", "2019", "current", "4", "1", "1", "2", "0", "", "", "2", "3", "2", "15.0000", "21.0000", "", "", "88.7", "90.0", "", "64.5", "", "2", "", "", "203", "1", "1", "163", "3", "1", "2", "0", "38", "0", "20", "4", "58", "", "1", "8.487", "0.117", "0.0", "2.30726", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.1", "96.5", "", "", "", "", "95.5"]} +{"pcdb_id": 18671, "brand_name": "Warmflow", "model_name": "I26C", "model_qualifier": "AGENTIS INTERNAL COMBI 26", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 90.0, "comparative_hot_water_efficiency_pct": 62.6, "output_kw_max": 27.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 1, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0, "loss_factor_f1_kwh_per_day": 2.56085, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018671", "000063", "0", "2020/Jan/22 13:11", "Warmflow Engineering", "Warmflow", "I26C", "AGENTIS INTERNAL COMBI 26", "", "2019", "current", "4", "1", "1", "2", "0", "", "", "2", "3", "2", "21.0000", "27.0000", "", "", "88.2", "90.0", "", "62.6", "", "2", "", "", "203", "1", "1", "140", "3", "1", "2", "0", "38", "0", "20", "4", "58", "", "1", "8.751", "0.108", "0.0", "2.56085", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.1", "95.1", "", "", "", "", "94.3"]} +{"pcdb_id": 18672, "brand_name": "Warmflow", "model_name": "I33C", "model_qualifier": "AGENTIS INTERNAL COMBI 33", "winter_efficiency_pct": 87.4, "summer_efficiency_pct": 89.9, "comparative_hot_water_efficiency_pct": 57.3, "output_kw_max": 32.7, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 1, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0, "loss_factor_f1_kwh_per_day": 3.31777, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018672", "000063", "0", "2020/Jan/22 13:11", "Warmflow Engineering", "Warmflow", "I33C", "AGENTIS INTERNAL COMBI 33", "", "2019", "current", "4", "1", "1", "2", "0", "", "", "2", "3", "2", "27", "32.7", "", "", "87.4", "89.9", "", "57.3", "", "2", "", "", "203", "1", "1", "148", "3", "1", "2", "0", "38", "0", "20", "4", "58", "", "1", "9.552", "0.088", "0.0", "3.31777", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.7", "93.2", "", "", "", "", "92.8"]} +{"pcdb_id": 18673, "brand_name": "Warmflow", "model_name": "B21", "model_qualifier": "Agentis Boiler House 21", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 80.9, "comparative_hot_water_efficiency_pct": 59.1, "output_kw_max": 21.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018673", "000063", "0", "2019/Sep/25 15:06", "Warmflow Engineering", "Warmflow", "B21", "Agentis Boiler House 21", "", "2019", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "15.0000", "21.0000", "", "", "88.7", "80.9", "", "59.1", "", "2", "", "", "201", "1", "1", " 152", " 0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.8", "96.2", "", "", "", "", "95.4"]} +{"pcdb_id": 18674, "brand_name": "Warmflow", "model_name": "E21", "model_qualifier": "Agentis External 21", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 80.9, "comparative_hot_water_efficiency_pct": 59.1, "output_kw_max": 21.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018674", "000063", "0", "2019/Sep/25 15:07", "Warmflow Engineering", "Warmflow", "E21", "Agentis External 21", "", "2019", "current", "4", "1", "2", "1", "0", "", "", "2", "3", "2", "15.0000", "21.0000", "", "", "88.7", "80.9", "", "59.1", "", "2", "", "", "201", "1", "1", " 152", " 0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.8", "96.2", "", "", "", "", "95.4"]} +{"pcdb_id": 18675, "brand_name": "Warmflow", "model_name": "I21", "model_qualifier": "Agentis Internal 21", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 80.9, "comparative_hot_water_efficiency_pct": 59.1, "output_kw_max": 21.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018675", "000063", "0", "2019/Sep/25 15:07", "Warmflow Engineering", "Warmflow", "I21", "Agentis Internal 21", "", "2019", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "15.0000", "21.0000", "", "", "88.7", "80.9", "", "59.1", "", "2", "", "", "201", "1", "1", " 152", " 0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "91.8", "96.2", "", "", "", "", "95.4"]} +{"pcdb_id": 18676, "brand_name": "Warmflow", "model_name": "B33", "model_qualifier": "Agentis Boiler House 33", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 32.7, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018676", "000063", "0", "2019/Sep/25 17:10", "Warmflow Engineering", "Warmflow", "B33", "Agentis Boiler House 33", "", "2019", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "27.1000", "32.7000", "", "", "88.0", "80.2", "", "58.6", "", "2", "", "", "201", "1", "1", " 147", " 0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.7", "94.7", "", "", "", "", "94.0"]} +{"pcdb_id": 18677, "brand_name": "Warmflow", "model_name": "E33", "model_qualifier": "Agentis External 33", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 32.7, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018677", "000063", "0", "2019/Sep/25 17:10", "Warmflow Engineering", "Warmflow", "E33", "Agentis External 33", "", "2019", "current", "4", "1", "2", "1", "0", "", "", "2", "3", "2", "27.1000", "32.7000", "", "", "88.0", "80.2", "", "58.6", "", "2", "", "", "201", "1", "1", " 147", " 0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.7", "94.7", "", "", "", "", "94.0"]} +{"pcdb_id": 18678, "brand_name": "Warmflow", "model_name": "I33", "model_qualifier": "Agentis Internal 33", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 32.7, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018678", "000063", "0", "2019/Sep/25 17:10", "Warmflow Engineering", "Warmflow", "I33", "Agentis Internal 33", "", "2019", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "27.1000", "32.7000", "", "", "88.0", "80.2", "", "58.6", "", "2", "", "", "201", "1", "1", " 147", " 0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "90.7", "94.7", "", "", "", "", "94.0"]} +{"pcdb_id": 18679, "brand_name": "Warmflow", "model_name": "E44", "model_qualifier": "Agentis External 44", "winter_efficiency_pct": 87.5, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 44.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018679", "000063", "0", "2019/Oct/21 09:47", "Warmflow Engineering", "Warmflow", "E44", "Agentis External 44", "", "2019", "current", "4", "1", "2", "1", "0", "", "", "2", "3", "2", "33", "44", "", "", "87.5", "79.7", "", "58.2", "", "2", "", "", "201", "1", "1", "190", "0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "89.6", "94.1", "", "", "", "", "93.2"]} +{"pcdb_id": 18680, "brand_name": "Warmflow", "model_name": "I44", "model_qualifier": "Agentis Internal 44", "winter_efficiency_pct": 87.5, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 44.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018680", "000063", "0", "2019/Oct/21 09:47", "Warmflow Engineering", "Warmflow", "I44", "Agentis Internal 44", "", "2019", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "33", "44", "", "", "87.5", "79.7", "", "58.2", "", "2", "", "", "201", "1", "1", "190", " 0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "", "", "", "", "89.6", "94.1", "", "", "", "", "93.2"]} +{"pcdb_id": 18681, "brand_name": "Baxi", "model_name": "818 SYSTEM", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 18.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018681", "000005", "0", "2020/Jan/20 13:48", "Baxi Heating", "Baxi", "818 SYSTEM", "", "41-470-73", "2019", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18", "18", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", " 30", " 3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "88.2", "97.8", "", "", "", "", "96.0"]} +{"pcdb_id": 18682, "brand_name": "Baxi", "model_name": "824 SYSTEM", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 24.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018682", "000005", "0", "2020/Jan/20 13:48", "Baxi Heating", "Baxi", "824 SYSTEM", "", "41-470-74", "2019", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24", "24", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", " 60", " 3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "88.0", "97.8", "", "", "", "", "95.9"]} +{"pcdb_id": 18683, "brand_name": "Baxi", "model_name": "825 COMBI", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 56.1, "output_kw_max": 20.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018683", "000005", "0", "2020/Jan/20 13:49", "Baxi Heating", "Baxi", "825 COMBI", "", "47-077-38", "2019", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "20", "20", "", "", "88.4", "79.8", "", "56.1", "", "2", "", "", "104", "1", "2", " 28", " 3", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "88.0", "97.8", "", "", "", "", "95.9"]} +{"pcdb_id": 18684, "brand_name": "Baxi", "model_name": "830 COMBI", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 56.1, "output_kw_max": 20.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018684", "000005", "0", "2020/Jan/20 13:49", "Baxi Heating", "Baxi", "830 COMBI", "", "47-077-39", "2019", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "20", "20", "", "", "88.4", "79.8", "", "56.1", "", "2", "", "", "104", "1", "2", " 36", " 3", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "88.0", "97.8", "", "", "", "", "95.9"]} +{"pcdb_id": 18685, "brand_name": "Baxi", "model_name": "836 COMBI", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 56.1, "output_kw_max": 25.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018685", "000005", "0", "2020/Jan/20 13:50", "Baxi Heating", "Baxi", "836 COMBI", "", "47-077-40", "2019", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "25", "25", "", "", "88.4", "79.8", "", "56.1", "", "2", "", "", "104", "1", "2", " 72", " 3", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "88.1", "97.8", "", "", "", "", "96.0"]} +{"pcdb_id": 18686, "brand_name": "Worcester", "model_name": "2000", "model_qualifier": "GC2000iW 25 C NG", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 86.6, "comparative_hot_water_efficiency_pct": 75.5, "output_kw_max": 20.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0024, "loss_factor_f1_kwh_per_day": 0.8438, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018686", "000035", "0", "2020/Jul/17 08:13", "Bosch Thermotechnology", "Worcester", "2000", "GC2000iW 25 C NG", "47-800-25", "2019", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "20.000", "20.000", "", "", "88.4", "86.6", "", "75.5", "", "2", "", "", "104", "1", "2", " 28", " 3", "0", "", "", "", "0", "", "", "", "", "1", "6.973", "0.078", "0.0024", "0.8438", "", "", "", "", "", "", "", "", "8305", "", "", "", "", "", "", "", "", "87.8", "98.0", "", "", "", "", "96.1"]} +{"pcdb_id": 18687, "brand_name": "Worcester", "model_name": "2000", "model_qualifier": "GC2000iW 30 C NG", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 86.6, "comparative_hot_water_efficiency_pct": 76.3, "output_kw_max": 20.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.005, "loss_factor_f1_kwh_per_day": 0.75911, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018687", "000035", "0", "2020/Jul/01 12:16", "Bosch Thermotechnology", "Worcester", "2000", "GC2000iW 30 C NG", "47-800-24", "2019", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "20.000", "20.000", "", "", "88.4", "86.6", "", "76.3", "", "2", "", "", "104", "1", "2", " 28", " 3", "0", "", "", "", "0", "", "", "", "", "1", "6.901", "0.069", "0.005", "0.75911", "", "", "", "", "", "", "", "", "8305", "", "", "", "", "", "", "", "", "87.8", "98.0", "", "", "", "", "96.1"]} +{"pcdb_id": 18688, "brand_name": "Glow-worm", "model_name": "MicraCom", "model_qualifier": "24c-AS/1 (H-GB)", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 86.6, "comparative_hot_water_efficiency_pct": 73.6, "output_kw_max": 18.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0008, "loss_factor_f1_kwh_per_day": 1.02612, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018688", "000207", "0", "2020/Jan/27 09:16", "Glow-worm", "Glow-worm", "MicraCom", "24c-AS/1 (H-GB)", "", "2019", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "18.3", "18.3", "", "", "88.0", "86.6", "", "73.6", "", "2", "", "", "104", "1", "2", " 27", " 2", "0", "", "", "", "0", "", "", "", "", "1", "7.151", "0.067", "0.0008", "1.02612", "", "", "", "", "", "", "", "", "0085", "", "", "", "", "", "", "", "", "87.8", "96.9", "", "", "", "", "95.1"]} +{"pcdb_id": 18689, "brand_name": "Glow-worm", "model_name": "MicraCom", "model_qualifier": "28c-AS/1 (H-GB)", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 86.6, "comparative_hot_water_efficiency_pct": 67.9, "output_kw_max": 23.9, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0203, "loss_factor_f1_kwh_per_day": 1.49449, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018689", "000207", "0", "2020/Jan/27 09:16", "Glow-worm", "Glow-worm", "MicraCom", "28c-AS/1 (H-GB)", "", "2019", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "23.9", "23.9", "", "", "88.3", "86.6", "", "67.9", "", "2", "", "", "104", "1", "2", " 35", " 2", "0", "", "", "", "0", "", "", "", "", "1", "7.759", "0.07", "0.0203", "1.49449", "", "", "", "", "", "", "", "", "0085", "", "", "", "", "", "", "", "", "87.8", "97.7", "", "", "", "", "95.8"]} +{"pcdb_id": 18690, "brand_name": "Heat Line", "model_name": "Enza", "model_qualifier": "24c-AS/1 (H-GB)", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 86.6, "comparative_hot_water_efficiency_pct": 73.6, "output_kw_max": 18.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0008, "loss_factor_f1_kwh_per_day": 1.02612, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018690", "000031", "0", "2020/Jan/27 09:18", "Vaillant", "Heat Line", "Enza", "24c-AS/1 (H-GB)", "", "2019", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "18.3", "18.3", "", "", "88.0", "86.6", "", "73.6", "", "2", "", "", "104", "1", "2", " 27", " 2", "0", "", "", "", "0", "", "", "", "", "1", "7.151", "0.067", "0.0008", "1.02612", "", "", "", "", "", "", "", "", "0045", "", "", "", "", "", "", "", "", "87.8", "96.9", "", "", "", "", "95.1"]} +{"pcdb_id": 18691, "brand_name": "Heat Line", "model_name": "Enza", "model_qualifier": "28c-AS/1 (H-GB)", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 86.6, "comparative_hot_water_efficiency_pct": 67.9, "output_kw_max": 23.9, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0203, "loss_factor_f1_kwh_per_day": 1.49449, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018691", "000031", "0", "2020/Jan/27 09:18", "Vaillant", "Heat Line", "Enza", "28c-AS/1 (H-GB)", "", "2019", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "23.9", "23.9", "", "", "88.3", "86.6", "", "67.9", "", "2", "", "", "104", "1", "2", " 35", " 2", "0", "", "", "", "0", "", "", "", "", "1", "7.759", "0.07", "0.0203", "1.49449", "", "", "", "", "", "", "", "", "0045", "", "", "", "", "", "", "", "", "87.8", "97.7", "", "", "", "", "95.8"]} +{"pcdb_id": 18692, "brand_name": "Ideal", "model_name": "LOGIC MAX COMBI", "model_qualifier": "C24IE", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 69.8, "output_kw_max": 24.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0027, "loss_factor_f1_kwh_per_day": 1.4524, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018692", "000008", "0", "2020/Jan/29 13:26", "Ideal Boilers", "Ideal", "LOGIC MAX COMBI", "C24IE", "47-349-87", "2020", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "88.9", "87.3", "", "69.8", "", "2", "", "", "104", "1", "2", "42", "5", "0", "", "", "", "0", "", "", "", "", "1", "7.549", "0.076", "0.0027", "1.4524", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "", "", "", "", "89.8", "98.3", "", "", "", "", "96.7"]} +{"pcdb_id": 18693, "brand_name": "Ideal", "model_name": "LOGIC MAX COMBI", "model_qualifier": "C24P IE", "winter_efficiency_pct": 90.1, "summer_efficiency_pct": 81.5, "comparative_hot_water_efficiency_pct": 57.3, "output_kw_max": 24.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018693", "000008", "0", "2020/Jan/13 11:12", "Ideal Boilers", "Ideal", "LOGIC MAX COMBI", "C24P IE", "", "2020", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "90.1", "81.5", "", "57.3", "", "2", "1", "", "104", "1", "2", " 42", "5", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "", "", "", "", "92.0", "100.8", "", "", "", "", "99.1"]} +{"pcdb_id": 18694, "brand_name": "Ideal", "model_name": "LOGIC MAX COMBI", "model_qualifier": "C30IE", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 70.4, "output_kw_max": 24.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0025, "loss_factor_f1_kwh_per_day": 1.38244, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018694", "000008", "0", "2020/Jan/29 13:26", "Ideal Boilers", "Ideal", "LOGIC MAX COMBI", "C30IE", "47-349-88", "2020", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "88.9", "87.3", "", "70.4", "", "2", "", "", "104", "1", "2", " 31", " 5", "0", "", "", "", "0", "", "", "", "", "1", "7.476", "0.074", "0.0025", "1.38244", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "", "", "", "", "89.8", "98.3", "", "", "", "", "96.7"]} +{"pcdb_id": 18695, "brand_name": "Ideal", "model_name": "LOGIC MAX COMBI", "model_qualifier": "C30P IE", "winter_efficiency_pct": 90.1, "summer_efficiency_pct": 81.5, "comparative_hot_water_efficiency_pct": 57.3, "output_kw_max": 24.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018695", "000008", "0", "2020/Jan/13 11:12", "Ideal Boilers", "Ideal", "LOGIC MAX COMBI", "C30P IE", "47-349-88", "2020", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "90.1", "81.5", "", "57.3", "", "2", "1", "", "104", "1", "2", " 31", "5", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "", "", "", "", "92.0", "100.8", "", "", "", "", "99.1"]} +{"pcdb_id": 18696, "brand_name": "Ideal", "model_name": "LOGIC MAX COMBI", "model_qualifier": "C35IE", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 71.1, "output_kw_max": 24.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0025, "loss_factor_f1_kwh_per_day": 1.32446, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018696", "000008", "0", "2020/Jan/22 13:12", "Ideal Boilers", "Ideal", "LOGIC MAX COMBI", "C35IE", "47-349-89", "2020", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "89.0", "87.3", "", "71.1", "", "2", "", "", "104", "1", "2", "29", "5", "0", "", "", "", "0", "", "", "", "", "1", "7.411", "0.074", "0.0025", "1.32446", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "", "", "", "", "90.0", "98.6", "", "", "", "", "96.9"]} +{"pcdb_id": 18697, "brand_name": "Ideal", "model_name": "LOGIC MAX HEAT", "model_qualifier": "H12IE", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 12.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018697", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "LOGIC MAX HEAT", "H12IE", "41-796-65", "2020", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "12.0", "12.0", "", "", "88.8", "79.8", "", "58.3", "", "2", "", "", "102", "1", "2", "20", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "90.0", "98.0", "", "", "", "", "96.5"]} +{"pcdb_id": 18698, "brand_name": "Ideal", "model_name": "LOGIC MAX HEAT", "model_qualifier": "H15IE", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 15.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018698", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "LOGIC MAX HEAT", "H15IE", "41-796-66", "2020", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "15.0", "15.0", "", "", "88.7", "79.7", "", "58.2", "", "2", "", "", "102", "1", "2", "21", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "90.0", "97.8", "", "", "", "", "96.4"]} +{"pcdb_id": 18699, "brand_name": "Ideal", "model_name": "LOGIC MAX HEAT", "model_qualifier": "H18IE", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 18.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018699", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "LOGIC MAX HEAT", "H18IE", "41-796-67", "2020", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18.0", "18.0", "", "", "89.1", "80.1", "", "58.5", "", "2", "", "", "102", "1", "2", "26", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "89.8", "98.8", "", "", "", "", "97.1"]} +{"pcdb_id": 18700, "brand_name": "Ideal", "model_name": "LOGIC MAX HEAT", "model_qualifier": "H24IE", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 24.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018700", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "LOGIC MAX HEAT", "H24IE", "41-796-68", "2020", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "88.9", "79.9", "", "58.4", "", "2", "", "", "102", "1", "2", "42", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "89.8", "98.3", "", "", "", "", "96.7"]} +{"pcdb_id": 18701, "brand_name": "Ideal", "model_name": "LOGIC MAX HEAT", "model_qualifier": "H24P IE", "winter_efficiency_pct": 89.9, "summer_efficiency_pct": 80.9, "comparative_hot_water_efficiency_pct": 59.1, "output_kw_max": 24.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018701", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "LOGIC MAX HEAT", "H24P IE", "", "2020", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "89.9", "80.9", "", "59.1", "", "2", "1", "", "102", "1", "2", "42", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "91.8", "100.5", "", "", "", "", "98.8"]} +{"pcdb_id": 18702, "brand_name": "Ideal", "model_name": "LOGIC MAX HEAT", "model_qualifier": "H30IE", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 30.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018702", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "LOGIC MAX HEAT", "H30IE", "41-796-69", "2020", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "30.3", "30.3", "", "", "88.9", "79.9", "", "58.4", "", "2", "", "", "102", "1", "2", "31", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "89.9", "98.3", "", "", "", "", "96.7"]} +{"pcdb_id": 18703, "brand_name": "Ideal", "model_name": "LOGIC MAX HEAT", "model_qualifier": "H30P IE", "winter_efficiency_pct": 89.9, "summer_efficiency_pct": 80.9, "comparative_hot_water_efficiency_pct": 59.1, "output_kw_max": 30.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018703", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "LOGIC MAX HEAT", "H30P IE", "41-796-69", "2020", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "30.3", "30.3", "", "", "89.9", "80.9", "", "59.1", "", "2", "1", "", "102", "1", "2", "31", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "91.9", "100.5", "", "", "", "", "98.9"]} +{"pcdb_id": 18704, "brand_name": "Ideal", "model_name": "LOGIC MAX SYSTEM", "model_qualifier": "S15IE", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 15.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018704", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "LOGIC MAX SYSTEM", "S15IE", "41-796-61", "2020", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "15.0", "15.0", "", "", "88.7", "79.7", "", "58.2", "", "2", "", "", "102", "1", "2", "21", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "90.0", "97.8", "", "", "", "", "96.4"]} +{"pcdb_id": 18705, "brand_name": "Ideal", "model_name": "LOGIC MAX SYSTEM", "model_qualifier": "S18IE", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 18.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018705", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "LOGIC MAX SYSTEM", "S18IE", "41-796-62", "2020", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18.0", "18.0", "", "", "89.1", "80.1", "", "58.5", "", "2", "", "", "102", "1", "2", "26", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "89.8", "98.8", "", "", "", "", "97.1"]} +{"pcdb_id": 18706, "brand_name": "Ideal", "model_name": "LOGIC MAX SYSTEM", "model_qualifier": "S24IE", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 24.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018706", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "LOGIC MAX SYSTEM", "S24IE", "41-796-63", "2020", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "88.9", "79.9", "", "58.4", "", "2", "", "", "102", "1", "2", "42", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "89.8", "98.3", "", "", "", "", "96.7"]} +{"pcdb_id": 18707, "brand_name": "Ideal", "model_name": "LOGIC MAX SYSTEM", "model_qualifier": "S24P IE", "winter_efficiency_pct": 89.9, "summer_efficiency_pct": 80.9, "comparative_hot_water_efficiency_pct": 59.1, "output_kw_max": 24.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018707", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "LOGIC MAX SYSTEM", "S24P IE", "", "2020", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "89.9", "80.9", "", "59.1", "", "2", "1", "", "102", "1", "2", "42", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "91.8", "100.5", "", "", "", "", "98.8"]} +{"pcdb_id": 18708, "brand_name": "Ideal", "model_name": "LOGIC MAX SYSTEM", "model_qualifier": "S30IE", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 30.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018708", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "LOGIC MAX SYSTEM", "S30IE", "41-796-64", "2020", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "30.3", "30.3", "", "", "88.9", "79.9", "", "58.4", "", "2", "", "", "102", "1", "2", "31", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "89.9", "98.3", "", "", "", "", "96.7"]} +{"pcdb_id": 18709, "brand_name": "Ideal", "model_name": "LOGIC MAX SYSTEM", "model_qualifier": "S30P IE", "winter_efficiency_pct": 89.9, "summer_efficiency_pct": 80.9, "comparative_hot_water_efficiency_pct": 59.1, "output_kw_max": 30.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018709", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "LOGIC MAX SYSTEM", "S30P IE", "41-796-64", "2020", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "30.3", "30.3", "", "", "89.9", "80.9", "", "59.1", "", "2", "1", "", "102", "1", "2", "31", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "91.9", "100.5", "", "", "", "", "98.9"]} +{"pcdb_id": 18710, "brand_name": "Ideal", "model_name": "VOGUE MAX COMBI", "model_qualifier": "26IE", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 87.2, "comparative_hot_water_efficiency_pct": 76.2, "output_kw_max": 18.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0012, "loss_factor_f1_kwh_per_day": 0.83988, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018710", "000008", "0", "2020/Jan/27 10:06", "Ideal Boilers", "Ideal", "VOGUE MAX COMBI", "26IE", "47-349-84", "2020", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "18.0", "18.0", "", "", "88.5", "87.2", "", "76.2", "", "2", "", "", "104", "1", "2", "47", "3", "0", "", "", "", "0", "", "", "", "", "1", "6.915", "0.085", "0.0012", "0.83988", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "", "", "", "", "89.6", "97.5", "", "", "", "", "96.0"]} +{"pcdb_id": 18711, "brand_name": "Ideal", "model_name": "VOGUE MAX COMBI", "model_qualifier": "26P IE", "winter_efficiency_pct": 89.5, "summer_efficiency_pct": 80.9, "comparative_hot_water_efficiency_pct": 56.9, "output_kw_max": 18.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018711", "000008", "0", "2020/Jan/27 10:06", "Ideal Boilers", "Ideal", "VOGUE MAX COMBI", "26P IE", "47-349-84", "2020", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "18.0", "18.0", "", "", "89.5", "80.9", "", "56.9", "", "2", "1", "", "104", "1", "2", "47", "3", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "", "", "", "", "91.5", "99.7", "", "", "", "", "98.1"]} +{"pcdb_id": 18712, "brand_name": "Ideal", "model_name": "VOGUE MAX COMBI", "model_qualifier": "32IE", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 87.2, "comparative_hot_water_efficiency_pct": 77.6, "output_kw_max": 26.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.001, "loss_factor_f1_kwh_per_day": 0.72046, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018712", "000008", "0", "2020/Jan/27 10:06", "Ideal Boilers", "Ideal", "VOGUE MAX COMBI", "32IE", "47-349-85", "2020", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "26.0", "26.0", "", "", "88.6", "87.2", "", "77.6", "", "2", "", "", "104", "1", "2", "63", "3", "0", "", "", "", "0", "", "", "", "", "1", "6.79", "0.087", "0.001", "0.72046", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "", "", "", "", "89.6", "97.6", "", "", "", "", "96.1"]} +{"pcdb_id": 18713, "brand_name": "Ideal", "model_name": "VOGUE MAX COMBI", "model_qualifier": "32P IE", "winter_efficiency_pct": 89.6, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 56.9, "output_kw_max": 26.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018713", "000008", "0", "2020/Jan/27 10:06", "Ideal Boilers", "Ideal", "VOGUE MAX COMBI", "32P IE", "47-349-85", "2020", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "26.0", "26.0", "", "", "89.6", "81.0", "", "56.9", "", "2", "1", "", "104", "1", "2", "63", "3", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "", "", "", "", "91.5", "99.7", "", "", "", "", "98.2"]} +{"pcdb_id": 18714, "brand_name": "Ideal", "model_name": "VOGUE MAX COMBI", "model_qualifier": "40IE", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 87.2, "comparative_hot_water_efficiency_pct": 77.2, "output_kw_max": 32.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0011, "loss_factor_f1_kwh_per_day": 0.74964, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018714", "000008", "0", "2020/Jan/27 10:08", "Ideal Boilers", "Ideal", "VOGUE MAX COMBI", "40IE", "47-349-86", "2020", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "32.0", "32.0", "", "", "88.5", "87.2", "", "77.2", "", "2", "", "", "104", "1", "2", "44", "3", "0", "", "", "", "0", "", "", "", "", "1", "6.821", "0.085", "0.0011", "0.74964", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "", "", "", "", "89.6", "97.3", "", "", "", "", "95.8"]} +{"pcdb_id": 18715, "brand_name": "Ideal", "model_name": "VOGUE MAX COMBI", "model_qualifier": "40P IE", "winter_efficiency_pct": 89.5, "summer_efficiency_pct": 80.9, "comparative_hot_water_efficiency_pct": 56.9, "output_kw_max": 32.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018715", "000008", "0", "2020/Jan/27 10:09", "Ideal Boilers", "Ideal", "VOGUE MAX COMBI", "40P IE", "47-349-86", "2020", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "32.0", "32.0", "", "", "89.5", "80.9", "", "56.9", "", "2", "1", "", "104", "1", "2", "44", "3", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "", "", "", "", "91.5", "99.5", "", "", "", "", "98.0"]} +{"pcdb_id": 18716, "brand_name": "Ideal", "model_name": "VOGUE MAX SYSTEM", "model_qualifier": "15IE", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 15.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018716", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "VOGUE MAX SYSTEM", "15IE", "41-750-57", "2020", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "15.0", "15.0", "", "", "88.2", "79.2", "", "57.9", "", "2", "", "", "102", "1", "2", "25", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "89.5", "96.8", "", "", "", "", "95.4"]} +{"pcdb_id": 18717, "brand_name": "Ideal", "model_name": "VOGUE MAX SYSTEM", "model_qualifier": "15P IE", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 15.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018717", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "VOGUE MAX SYSTEM", "15P IE", "41-750-57", "2020", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "15.0", "15.0", "", "", "89.2", "80.2", "", "58.6", "", "2", "1", "", "102", "1", "2", "25", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "91.5", "98.9", "", "", "", "", "97.5"]} +{"pcdb_id": 18718, "brand_name": "Ideal", "model_name": "VOGUE MAX SYSTEM", "model_qualifier": "18IE", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 18.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018718", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "VOGUE MAX SYSTEM", "18IE", "41-750-58", "2020", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18.0", "18.0", "", "", "88.6", "79.6", "", "58.1", "", "2", "", "", "102", "1", "2", "40", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "89.5", "97.7", "", "", "", "", "96.1"]} +{"pcdb_id": 18719, "brand_name": "Ideal", "model_name": "VOGUE MAX SYSTEM", "model_qualifier": "18P IE", "winter_efficiency_pct": 89.6, "summer_efficiency_pct": 80.6, "comparative_hot_water_efficiency_pct": 58.9, "output_kw_max": 18.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018719", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "VOGUE MAX SYSTEM", "18P IE", "41-750-58", "2020", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "18.0", "18.0", "", "", "89.6", "80.6", "", "58.9", "", "2", "1", "", "102", "1", "2", "40", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "91.5", "99.8", "", "", "", "", "98.2"]} +{"pcdb_id": 18720, "brand_name": "Ideal", "model_name": "VOGUE MAX SYSTEM", "model_qualifier": "26IE", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 26.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018720", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "VOGUE MAX SYSTEM", "26IE", "41-750-59", "2020", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "26.0", "26.0", "", "", "88.5", "79.5", "", "58.1", "", "2", "1", "", "102", "1", "2", "45", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "89.6", "97.5", "", "", "", "", "96.0"]} +{"pcdb_id": 18721, "brand_name": "Ideal", "model_name": "VOGUE MAX SYSTEM", "model_qualifier": "26P IE", "winter_efficiency_pct": 89.5, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 58.8, "output_kw_max": 26.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018721", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "VOGUE MAX SYSTEM", "26P IE", "", "2020", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "26.0", "26.0", "", "", "89.5", "80.5", "", "58.8", "", "2", "1", "", "102", "1", "2", "45", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "91.5", "99.7", "", "", "", "", "98.1"]} +{"pcdb_id": 18722, "brand_name": "Ideal", "model_name": "VOGUE MAX SYSTEM", "model_qualifier": "32IE", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 32.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018722", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "VOGUE MAX SYSTEM", "32IE", "41-796-60", "2020", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "32.0", "32.0", "", "", "88.6", "79.6", "", "58.2", "", "2", "", "", "102", "1", "2", "49", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "89.8", "97.7", "", "", "", "", "96.2"]} +{"pcdb_id": 18723, "brand_name": "Ideal", "model_name": "VOGUE MAX SYSTEM", "model_qualifier": "32P IE", "winter_efficiency_pct": 89.7, "summer_efficiency_pct": 80.7, "comparative_hot_water_efficiency_pct": 58.9, "output_kw_max": 32.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018723", "000008", "0", "2021/Jun/02 18:30", "Ideal Boilers", "Ideal", "VOGUE MAX SYSTEM", "32P IE", "41-796-60", "2020", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "32.0", "32.0", "", "", "89.7", "80.7", "", "58.9", "", "2", "1", "", "102", "1", "2", "49", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "91.8", "99.8", "", "", "", "", "98.3"]} +{"pcdb_id": 18724, "brand_name": "Vokera BY RIELLO", "model_name": "Easi-Heat Plus", "model_qualifier": "32Ci", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 56.1, "output_kw_max": 24.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018724", "000011", "0", "2020/Oct/15 09:59", "Vokera", "Vokera BY RIELLO", "Easi-Heat Plus", "32Ci", "20158336", "2019", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.5", "24.5", "", "", "88.4", "79.8", "", "56.1", "", "2", "", "", "104", "1", "2", "38", "5.6", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "88.1", "97.7", "", "", "", "", "95.9"]} +{"pcdb_id": 18725, "brand_name": "Vokera BY RIELLO", "model_name": "Compact", "model_qualifier": "32A", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 56.1, "output_kw_max": 24.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018725", "000011", "0", "2020/Oct/15 09:56", "Vokera", "Vokera BY RIELLO", "Compact", "32A", "20166153", "2018", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.5", "24.5", "", "", "88.4", "79.8", "", "56.1", "", "2", "", "", "104", "1", "2", "38", "2.4", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "88.1", "97.7", "", "", "", "", "95.9"]} +{"pcdb_id": 18726, "brand_name": "Alpha", "model_name": "E-Tec", "model_qualifier": "15R", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 15.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018726", "000001", "0", "2019/Dec/16 15:48", "Alpha Therm", "Alpha", "E-Tec", "15R", "3.028463", "2019", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "15.4", "15.4", "", "", "88.2", "79.2", "", "57.9", "", "2", "", "", "102", "1", "2", "23", "7", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "1005", "", "", "", "", "", "", "", "", "88.1", "97.3", "", "", "", "", "95.6"]} +{"pcdb_id": 18727, "brand_name": "Alpha", "model_name": "E-Tec", "model_qualifier": "15R", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 15.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018727", "000001", "0", "2019/Dec/16 15:48", "Alpha Therm", "Alpha", "E-Tec", "15R", "3.028463GPL", "2019", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "15.4", "15.4", "", "", "89.2", "80.2", "", "58.6", "", "2", "1", "", "102", "1", "2", "23", "7", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "1005", "", "", "", "", "", "", "", "", "90.1", "99.5", "", "", "", "", "97.7"]} +{"pcdb_id": 18728, "brand_name": "Alpha", "model_name": "E-Tec", "model_qualifier": "20R", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 20.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018728", "000001", "0", "2019/Dec/16 15:48", "Alpha Therm", "Alpha", "E-Tec", "20R", "3.028464", "2019", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "20.5", "20.5", "", "", "88.3", "79.3", "", "57.9", "", "2", "", "", "102", "1", "2", "32", "7", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "1005", "", "", "", "", "", "", "", "", "87.7", "97.6", "", "", "", "", "95.7"]} +{"pcdb_id": 18729, "brand_name": "Alpha", "model_name": "E-Tec", "model_qualifier": "20R", "winter_efficiency_pct": 89.3, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 20.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018729", "000001", "0", "2019/Dec/16 15:48", "Alpha Therm", "Alpha", "E-Tec", "20R", "3.028464GPL", "2019", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "20.5", "20.5", "", "", "89.3", "80.3", "", "58.6", "", "2", "1", "", "102", "1", "2", "32", "7", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "1005", "", "", "", "", "", "", "", "", "89.6", "99.7", "", "", "", "", "97.8"]} +{"pcdb_id": 18731, "brand_name": "Lukey", "model_name": "28 HE", "model_qualifier": "", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 88.2, "comparative_hot_water_efficiency_pct": 76.5, "output_kw_max": 17.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.008, "loss_factor_f1_kwh_per_day": 0.72973, "loss_factor_f2_kwh_per_day": 0.7123, "rejected_factor_f3_per_litre": 5e-05, "raw": ["018731", "000314", "0", "2020/Aug/17 15:54", "Lukey Cassette Boilers (UK)", "Lukey", "28 HE", "", "", "2018", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "17.5", "17.5", "", "", "89.0", "88.2", "", "76.5", "", "2", "", "", "104", "1", "2", "20.6", "2", "0", "", "", "", "0", "", "", "", "", "2", "6.884", "0.074", "0.008", "0.72973", "12.627", "0.1", "0.003", "0.7123", "0.00005", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.9", "99.3", "", "", "", "", "97.1"]} +{"pcdb_id": 18732, "brand_name": "Lukey", "model_name": "28 HE", "model_qualifier": "", "winter_efficiency_pct": 90.0, "summer_efficiency_pct": 81.4, "comparative_hot_water_efficiency_pct": 57.2, "output_kw_max": 17.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018732", "000314", "0", "2020/Aug/17 15:53", "Lukey Cassette Boilers (UK)", "Lukey", "28 HE", "", "", "2018", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "17.5", "17.5", "", "", "90.0", "81.4", "", "57.2", "", "2", "1", "", "104", "1", "2", "20.6", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.9", "101.5", "", "", "", "", "99.3"]} +{"pcdb_id": 18733, "brand_name": "Vokera BY RIELLO", "model_name": "Easi-Heat Plus", "model_qualifier": "25Ci", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 56.2, "output_kw_max": 19.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018733", "000011", "0", "2020/Aug/13 07:53", "Vokera", "Vokera BY RIELLO", "Easi-Heat Plus", "25Ci", "20158332", "2019", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "19.5", "19.5", "", "", "88.5", "79.9", "", "56.2", "", "2", "", "", "104", "1", "2", "29", "5.6", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "98.1", "", "", "", "", "96.2"]} +{"pcdb_id": 18734, "brand_name": "Vokera BY RIELLO", "model_name": "Easi-Heat Plus", "model_qualifier": "29Ci", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 56.1, "output_kw_max": 24.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018734", "000011", "0", "2020/Aug/13 07:54", "Vokera", "Vokera BY RIELLO", "Easi-Heat Plus", "29Ci", "20158334", "2019", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.5", "24.5", "", "", "88.4", "79.8", "", "56.1", "", "2", "", "", "104", "1", "2", "38.0", "5.6", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.1", "97.7", "", "", "", "", "95.9"]} +{"pcdb_id": 18736, "brand_name": "Baxi", "model_name": "ASSURE", "model_qualifier": "25 COMBI", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 86.7, "comparative_hot_water_efficiency_pct": 80.2, "output_kw_max": 20.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0005, "loss_factor_f1_kwh_per_day": 0.46696, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018736", "000005", "0", "2020/Mar/09 09:05", "Baxi Heating", "Baxi", "ASSURE", "25 COMBI", "47-077-42", "2020", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "20.0", "20.0", "", "", "88.4", "86.7", "", "80.2", "", "2", "", "", "104", "1", "2", " 28", " 3", "0", "", "", "", "0", "", "", "", "", "1", "6.563", "0.102", "0.0005", "0.46696", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "88.0", "97.8", "", "", "", "", "95.9"]} +{"pcdb_id": 18737, "brand_name": "Baxi", "model_name": "ASSURE", "model_qualifier": "30 COMBI", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 86.7, "comparative_hot_water_efficiency_pct": 79.3, "output_kw_max": 25.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.001, "loss_factor_f1_kwh_per_day": 0.54126, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018737", "000005", "0", "2020/Mar/09 13:00", "Baxi Heating", "Baxi", "ASSURE", "30 COMBI", "47-077-43", "2020", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "25.0", "25.0", "", "", "88.4", "86.7", "", "79.3", "", "2", "", "", "104", "1", "2", " 38", " 3", "0", "", "", "", "0", "", "", "", "", "1", "6.641", "0.105", "0.001", "0.54126", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "88.1", "97.8", "", "", "", "", "96.0"]} +{"pcdb_id": 18738, "brand_name": "Baxi", "model_name": "ASSURE", "model_qualifier": "36 COMBI", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 86.7, "comparative_hot_water_efficiency_pct": 81.4, "output_kw_max": 25.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0015, "loss_factor_f1_kwh_per_day": 0.37374, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018738", "000005", "0", "2020/Mar/09 09:05", "Baxi Heating", "Baxi", "ASSURE", "36 COMBI", "47-077-44", "2020", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "25.0", "25.0", "", "", "88.4", "86.7", "", "81.4", "", "2", "", "", "104", "1", "2", " 72", "3", "0", "", "", "", "0", "", "", "", "", "1", "6.47", "0.102", "0.0015", "0.37374", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "88.1", "97.8", "", "", "", "", "96.0"]} +{"pcdb_id": 18739, "brand_name": "Baxi", "model_name": "ASSURE", "model_qualifier": "25 COMBI LPG", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 88.6, "comparative_hot_water_efficiency_pct": 80.0, "output_kw_max": 20.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.002, "loss_factor_f1_kwh_per_day": 0.61406, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018739", "000005", "0", "2020/Mar/09 09:05", "Baxi Heating", "Baxi", "ASSURE", "25 COMBI LPG", "47-077-45", "2020", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "20.0", "20.0", "", "", "89.4", "88.6", "", "80.0", "", "2", "1", "", "104", "1", "2", " 28", " 3", "0", "", "", "", "0", "", "", "", "", "1", "6.725", "0.104", "0.002", "0.61406", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "90.0", "99.9", "", "", "", "", "98.0"]} +{"pcdb_id": 18740, "brand_name": "Baxi", "model_name": "ASSURE", "model_qualifier": "30 COMBI LPG", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 88.6, "comparative_hot_water_efficiency_pct": 80.1, "output_kw_max": 25.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0015, "loss_factor_f1_kwh_per_day": 0.60929, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018740", "000005", "0", "2020/Mar/09 13:00", "Baxi Heating", "Baxi", "ASSURE", "30 COMBI LPG", "47-077-46", "2020", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "25.0", "25.0", "", "", "89.4", "88.6", "", "80.1", "", "2", "1", "", "104", "1", "2", "38", "3", "0", "", "", "", "0", "", "", "", "", "1", "6.717", "0.103", "0.0015", "0.60929", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "90.0", "99.9", "", "", "", "", "98.0"]} +{"pcdb_id": 18741, "brand_name": "Baxi", "model_name": "ASSURE", "model_qualifier": "36 COMBI LPG", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 88.6, "comparative_hot_water_efficiency_pct": 79.8, "output_kw_max": 25.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0015, "loss_factor_f1_kwh_per_day": 0.64132, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018741", "000005", "0", "2020/Mar/09 09:15", "Baxi Heating", "Baxi", "ASSURE", "36 COMBI LPG", "47-077-47", "2020", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "25.0", "25.0", "", "", "89.4", "88.6", "", "79.8", "", "2", "1", "", "104", "1", "2", "72", "3", "0", "", "", "", "0", "", "", "", "", "1", "6.748", "0.102", "0.0015", "0.64132", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "90.1", "100.0", "", "", "", "", "98.1"]} +{"pcdb_id": 18742, "brand_name": "Baxi", "model_name": "ASSURE", "model_qualifier": "12 SYSTEM", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 12.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018742", "000005", "0", "2020/Mar/09 09:42", "Baxi Heating", "Baxi", "ASSURE", "12 SYSTEM", "41-470-85", "2020", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "12.0", "12.0", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", " 20", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "88.2", "97.8", "", "", "", "", "96.0"]} +{"pcdb_id": 18743, "brand_name": "Baxi", "model_name": "ASSURE", "model_qualifier": "15 SYSTEM", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 15.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018743", "000005", "0", "2020/Mar/09 09:43", "Baxi Heating", "Baxi", "ASSURE", "15 SYSTEM", "41-470-86", "2020", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "15.0", "15.0", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "25", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "88.2", "97.8", "", "", "", "", "95.9"]} +{"pcdb_id": 18744, "brand_name": "Baxi", "model_name": "ASSURE", "model_qualifier": "18 SYSTEM", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 18.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018744", "000005", "0", "2020/Mar/09 09:43", "Baxi Heating", "Baxi", "ASSURE", "18 SYSTEM", "41-479-87", "2020", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18.0", "18.0", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "30", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "88.2", "97.8", "", "", "", "", "96.0"]} +{"pcdb_id": 18745, "brand_name": "Baxi", "model_name": "ASSURE", "model_qualifier": "24 SYSTEM", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 24.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018745", "000005", "0", "2020/Mar/09 09:43", "Baxi Heating", "Baxi", "ASSURE", "24 SYSTEM", "41-470-88", "2020", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24.0", "24.0", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "60", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "88.0", "97.8", "", "", "", "", "95.9"]} +{"pcdb_id": 18746, "brand_name": "Baxi", "model_name": "ASSURE", "model_qualifier": "18 SYSTEM LPG", "winter_efficiency_pct": 89.5, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 58.8, "output_kw_max": 18.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018746", "000005", "0", "2020/Mar/09 09:44", "Baxi Heating", "Baxi", "ASSURE", "18 SYSTEM LPG", "41-479-92", "2020", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "18.0", "18.0", "", "", "89.5", "80.5", "", "58.8", "", "2", "1", "", "102", "1", "2", "30", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "90.2", "100.0", "", "", "", "", "98.1"]} +{"pcdb_id": 18747, "brand_name": "Baxi", "model_name": "ASSURE", "model_qualifier": "24 SYSTEM LPG", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 80.4, "comparative_hot_water_efficiency_pct": 58.7, "output_kw_max": 24.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018747", "000005", "0", "2020/Mar/09 09:44", "Baxi Heating", "Baxi", "ASSURE", "24 SYSTEM LPG", "41-470-93", "2020", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "24.0", "24.0", "", "", "89.4", "80.4", "", "58.7", "", "2", "1", "", "102", "1", "2", "60", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "90.0", "99.9", "", "", "", "", "98.0"]} +{"pcdb_id": 18748, "brand_name": "Baxi", "model_name": "ASSURE", "model_qualifier": "13 HEAT", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 13.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018748", "000005", "0", "2020/Jun/01 12:11", "Baxi Heating", "Baxi", "ASSURE", "13 HEAT", "41-470-80", "2020", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "13.0", "13.0", "", "", "88.6", "79.6", "", "58.2", "", "2", "", "", "102", "1", "2", "17", " 0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "98.4", "", "", "", "", "96.4"]} +{"pcdb_id": 18749, "brand_name": "Baxi", "model_name": "ASSURE", "model_qualifier": "16 HEAT", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 16.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018749", "000005", "0", "2020/Jun/01 12:12", "Baxi Heating", "Baxi", "ASSURE", "16 HEAT", "41-470-81", "2020", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "16.0", "16.0", "", "", "88.6", "79.6", "", "58.2", "", "2", "", "", "102", "1", "2", "20", " 0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "98.4", "", "", "", "", "96.4"]} +{"pcdb_id": 18750, "brand_name": "Baxi", "model_name": "ASSURE", "model_qualifier": "19 HEAT", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 19.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018750", "000005", "0", "2020/Jun/01 12:12", "Baxi Heating", "Baxi", "ASSURE", "19 HEAT", "41-470-82", "2020", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "19.0", "19.0", "", "", "88.6", "79.6", "", "58.2", "", "2", "", "", "102", "1", "2", "23", " 0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "98.4", "", "", "", "", "96.4"]} +{"pcdb_id": 18751, "brand_name": "Baxi", "model_name": "ASSURE", "model_qualifier": "25 HEAT", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 25.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018751", "000005", "0", "2020/Jun/01 12:22", "Baxi Heating", "Baxi", "ASSURE", "25 HEAT", "41-470-83", "2020", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "25.0", "25.0", "", "", "88.6", "79.6", "", "58.2", "", "2", "", "", "102", "1", "2", "33", " 0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "98.4", "", "", "", "", "96.4"]} +{"pcdb_id": 18752, "brand_name": "Baxi", "model_name": "ASSURE", "model_qualifier": "30 HEAT", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 30.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018752", "000005", "0", "2020/Mar/19 14:39", "Baxi Heating", "Baxi", "ASSURE", "30 HEAT", "41-470-84", "2020", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "30.0", "30.0", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "44", " 0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.3", "98.0", "", "", "", "", "96.0"]} +{"pcdb_id": 18753, "brand_name": "Baxi", "model_name": "613 HEAT", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 13.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018753", "000005", "0", "2020/Jun/01 12:23", "Baxi Heating", "Baxi", "613 HEAT", "", "41-470-66", "2020", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "13.0", "13.0", "", "", "88.6", "79.6", "", "58.2", "", "2", "", "", "102", "1", "2", "17", " 0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "98.4", "", "", "", "", "96.4"]} +{"pcdb_id": 18754, "brand_name": "Baxi", "model_name": "616 HEAT", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 16.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018754", "000005", "0", "2020/Jun/01 12:24", "Baxi Heating", "Baxi", "616 HEAT", "", "41-470-67", "2020", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "16.0", "16.0", "", "", "88.6", "79.6", "", "58.2", "", "2", "", "", "102", "1", "2", "20", " 0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "98.4", "", "", "", "", "96.4"]} +{"pcdb_id": 18755, "brand_name": "Baxi", "model_name": "619 HEAT", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 19.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018755", "000005", "0", "2020/Jun/01 12:26", "Baxi Heating", "Baxi", "619 HEAT", "", "41-470-68", "2020", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "19.0", "19.0", "", "", "88.6", "79.6", "", "58.2", "", "2", "", "", "102", "1", "2", "23", " 0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "98.4", "", "", "", "", "96.4"]} +{"pcdb_id": 18756, "brand_name": "Baxi", "model_name": "625 HEAT", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 25.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018756", "000005", "0", "2020/Jun/01 12:26", "Baxi Heating", "Baxi", "625 HEAT", "", "41-470-69", "2020", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "25.0", "25.0", "", "", "88.6", "79.6", "", "58.2", "", "2", "", "", "102", "1", "2", "33", " 0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "98.4", "", "", "", "", "96.4"]} +{"pcdb_id": 18757, "brand_name": "Baxi", "model_name": "630 HEAT", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 30.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018757", "000005", "0", "2020/Mar/19 14:36", "Baxi Heating", "Baxi", "630 HEAT", "", "41-470-70", "2020", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "30.0", "30.0", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "44", " 0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.3", "98.0", "", "", "", "", "96.0"]} +{"pcdb_id": 18758, "brand_name": "Ideal", "model_name": "INSTINCT2", "model_qualifier": "24", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 70.0, "output_kw_max": 24.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0027, "loss_factor_f1_kwh_per_day": 1.43483, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018758", "000008", "0", "2020/Sep/22 17:49", "Ideal Boilers", "Ideal", "INSTINCT2", "24", "47-349-68", "2019", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "89.0", "87.3", "", "70.0", "", "2", "", "", "104", "1", "2", "42", "3", "0", "", "", "", "0", "", "", "", "", "1", "7.526", "0.12", "0.0027", "1.43483", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.0", "98.6", "", "", "", "", "96.9"]} +{"pcdb_id": 18759, "brand_name": "Ideal", "model_name": "INSTINCT2", "model_qualifier": "30", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 69.5, "output_kw_max": 24.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0027, "loss_factor_f1_kwh_per_day": 1.48359, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018759", "000008", "0", "2020/Sep/22 18:01", "Ideal Boilers", "Ideal", "INSTINCT2", "30", "47-349-69", "2019", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "89.0", "87.3", "", "69.5", "", "2", "", "", "104", "1", "2", "32", "3", "0", "", "", "", "0", "", "", "", "", "1", "7.576", "0.119", "0.0027", "1.48359", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.0", "98.6", "", "", "", "", "96.9"]} +{"pcdb_id": 18760, "brand_name": "Ideal", "model_name": "INSTINCT2", "model_qualifier": "35", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 70.3, "output_kw_max": 24.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0026, "loss_factor_f1_kwh_per_day": 1.40519, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018760", "000008", "0", "2020/Sep/22 18:02", "Ideal Boilers", "Ideal", "INSTINCT2", "35", "47-349-70", "2019", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "89.0", "87.3", "", "70.3", "", "2", "", "", "104", "1", "2", "29", "3", "0", "", "", "", "0", "", "", "", "", "1", "7.495", "0.119", "0.0026", "1.40519", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.0", "98.6", "", "", "", "", "96.9"]} +{"pcdb_id": 18761, "brand_name": "Ideal", "model_name": "ATLANTIC COMBI", "model_qualifier": "24", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 67.3, "output_kw_max": 24.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0027, "loss_factor_f1_kwh_per_day": 1.7208, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018761", "000008", "0", "2020/Sep/22 18:02", "Ideal Boilers", "Ideal", "ATLANTIC COMBI", "24", "47-349-81", "2019", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "89.0", "87.3", "", "67.3", "", "2", "", "", "104", "1", "2", "42", "3", "0", "", "", "", "0", "", "", "", "", "1", "7.821", "0.119", "0.0027", "1.7208", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.0", "98.6", "", "", "", "", "96.9"]} +{"pcdb_id": 18762, "brand_name": "Ideal", "model_name": "ATLANTIC COMBI", "model_qualifier": "30", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 69.5, "output_kw_max": 24.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0027, "loss_factor_f1_kwh_per_day": 1.48359, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018762", "000008", "0", "2020/Sep/22 18:02", "Ideal Boilers", "Ideal", "ATLANTIC COMBI", "30", "47-349-82", "2019", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "89.0", "87.3", "", "69.5", "", "2", "", "", "104", "1", "2", "32", "3", "0", "", "", "", "0", "", "", "", "", "1", "7.576", "0.119", "0.0027", "1.48359", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.0", "98.6", "", "", "", "", "96.9"]} +{"pcdb_id": 18763, "brand_name": "Ideal", "model_name": "ATLANTIC COMBI", "model_qualifier": "35", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 70.3, "output_kw_max": 24.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0026, "loss_factor_f1_kwh_per_day": 1.40519, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018763", "000008", "0", "2020/Sep/22 18:03", "Ideal Boilers", "Ideal", "ATLANTIC COMBI", "35", "47-349-83", "2019", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "89.0", "87.3", "", "70.3", "", "2", "", "", "104", "1", "2", "29", "3", "0", "", "", "", "0", "", "", "", "", "1", "7.495", "0.119", "0.0026", "1.40519", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.0", "98.6", "", "", "", "", "96.9"]} +{"pcdb_id": 18764, "brand_name": "Ideal", "model_name": "CLASSIC2", "model_qualifier": "24", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 70.0, "output_kw_max": 24.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0027, "loss_factor_f1_kwh_per_day": 1.43483, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018764", "000008", "0", "2020/Sep/22 18:03", "Ideal Boilers", "Ideal", "CLASSIC2", "24", "47-349-71", "2019", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "89.0", "87.3", "", "70.0", "", "2", "", "", "104", "1", "2", "42", "3", "0", "", "", "", "0", "", "", "", "", "1", "7.526", "0.12", "0.0027", "1.43483", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.0", "98.6", "", "", "", "", "96.9"]} +{"pcdb_id": 18765, "brand_name": "Ideal", "model_name": "CLASSIC2", "model_qualifier": "30", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 69.5, "output_kw_max": 24.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0027, "loss_factor_f1_kwh_per_day": 1.48359, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018765", "000008", "0", "2020/Sep/22 18:03", "Ideal Boilers", "Ideal", "CLASSIC2", "30", "47-349-72", "2019", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "89.0", "87.3", "", "69.5", "", "2", "", "", "104", "1", "2", "32", "3", "0", "", "", "", "0", "", "", "", "", "1", "7.576", "1.119", "0.0027", "1.48359", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.0", "98.6", "", "", "", "", "96.9"]} +{"pcdb_id": 18766, "brand_name": "Ideal", "model_name": "CLASSIC2", "model_qualifier": "35", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 70.3, "output_kw_max": 24.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0026, "loss_factor_f1_kwh_per_day": 1.40519, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018766", "000008", "0", "2020/Sep/22 18:03", "Ideal Boilers", "Ideal", "CLASSIC2", "35", "47-349-73", "2019", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "89.0", "87.3", "", "70.3", "", "2", "", "", "104", "1", "2", "29", "3", "0", "", "", "", "0", "", "", "", "", "1", "7.495", "0.119", "0.0026", "1.40519", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.0", "98.6", "", "", "", "", "96.9"]} +{"pcdb_id": 18767, "brand_name": "Ideal", "model_name": "ESPRIT ECO2", "model_qualifier": "24", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 70.0, "output_kw_max": 24.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0027, "loss_factor_f1_kwh_per_day": 1.43483, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018767", "000008", "0", "2020/Sep/22 18:03", "Ideal Boilers", "Ideal", "ESPRIT ECO2", "24", "47-349-65", "2019", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "89.0", "87.3", "", "70.0", "", "2", "", "", "104", "1", "2", "29", "3", "0", "", "", "", "0", "", "", "", "", "1", "7.526", "0.12", "0.0027", "1.43483", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.0", "98.6", "", "", "", "", "96.9"]} +{"pcdb_id": 18768, "brand_name": "Ideal", "model_name": "ESPRIT ECO2", "model_qualifier": "30", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 69.5, "output_kw_max": 24.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0027, "loss_factor_f1_kwh_per_day": 1.48359, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018768", "000008", "0", "2020/Sep/22 18:03", "Ideal Boilers", "Ideal", "ESPRIT ECO2", "30", "47-349-66", "2019", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "89.0", "87.3", "", "69.5", "", "2", "", "", "104", "1", "2", "32", "3", "0", "", "", "", "0", "", "", "", "", "1", "7.576", "0.119", "0.0027", "1.48359", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.0", "98.6", "", "", "", "", "96.9"]} +{"pcdb_id": 18769, "brand_name": "Ideal", "model_name": "ESPRIT ECO2", "model_qualifier": "35", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 70.3, "output_kw_max": 24.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0026, "loss_factor_f1_kwh_per_day": 1.40519, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018769", "000008", "0", "2020/Sep/22 18:03", "Ideal Boilers", "Ideal", "ESPRIT ECO2", "35", "47-349-67", "2019", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "89.0", "87.3", "", "70.3", "", "2", "", "", "104", "1", "2", "29", "3", "0", "", "", "", "0", "", "", "", "", "1", "7.495", "0.119", "0.0026", "1.40519", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.0", "98.6", "", "", "", "", "96.9"]} +{"pcdb_id": 18770, "brand_name": "Ideal", "model_name": "I2 COMBI", "model_qualifier": "24", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 70.0, "output_kw_max": 24.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0027, "loss_factor_f1_kwh_per_day": 1.43483, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018770", "000008", "0", "2020/Sep/22 18:03", "Ideal Boilers", "Ideal", "I2 COMBI", "24", "47-349-74", "2019", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "89.0", "87.3", "", "70.0", "", "2", "", "", "104", "1", "2", "42", "3", "0", "", "", "", "0", "", "", "", "", "1", "7.526", "0.12", "0.0027", "1.43483", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.0", "98.6", "", "", "", "", "96.9"]} +{"pcdb_id": 18771, "brand_name": "Ideal", "model_name": "I2 COMBI", "model_qualifier": "30", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 69.5, "output_kw_max": 24.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0027, "loss_factor_f1_kwh_per_day": 1.48359, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018771", "000008", "0", "2020/Sep/22 18:03", "Ideal Boilers", "Ideal", "I2 COMBI", "30", "47-349-75", "2019", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "89.0", "87.3", "", "69.5", "", "2", "", "", "104", "1", "2", "32", "3", "0", "", "", "", "0", "", "", "", "", "1", "7.576", "0.119", "0.0027", "1.48359", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.0", "98.6", "", "", "", "", "96.9"]} +{"pcdb_id": 18772, "brand_name": "Ideal", "model_name": "I2 COMBI", "model_qualifier": "35", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 70.3, "output_kw_max": 24.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0026, "loss_factor_f1_kwh_per_day": 1.40519, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018772", "000008", "0", "2020/Sep/22 18:03", "Ideal Boilers", "Ideal", "I2 COMBI", "35", "47-349-76", "2019", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "89.0", "87.3", "", "70.3", "", "2", "", "", "104", "1", "2", "29", "3", "0", "", "", "", "0", "", "", "", "", "1", "7.495", "0.119", "0.0026", "1.40519", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.0", "98.6", "", "", "", "", "96.9"]} +{"pcdb_id": 18773, "brand_name": "Ideal", "model_name": "EXCLUSIVE2", "model_qualifier": "24", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 70.0, "output_kw_max": 24.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0027, "loss_factor_f1_kwh_per_day": 1.43483, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018773", "000008", "0", "2020/Sep/22 18:04", "Ideal Boilers", "Ideal", "EXCLUSIVE2", "24", "47-349-62", "2019", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "89.0", "87.3", "", "70.0", "", "2", "", "", "104", "1", "2", "42", "3", "0", "", "", "", "0", "", "", "", "", "1", "7.526", "0.12", "0.0027", "1.43483", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.0", "98.6", "", "", "", "", "96.9"]} +{"pcdb_id": 18774, "brand_name": "Ideal", "model_name": "EXCLUSIVE2", "model_qualifier": "30", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 69.5, "output_kw_max": 24.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0027, "loss_factor_f1_kwh_per_day": 1.48359, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018774", "000008", "0", "2020/Sep/22 18:04", "Ideal Boilers", "Ideal", "EXCLUSIVE2", "30", "47-349-63", "2019", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "89.0", "87.3", "", "69.5", "", "2", "", "", "104", "1", "2", "32", "3", "0", "", "", "", "0", "", "", "", "", "1", "7.576", "0.119", "0.0027", "1.48359", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.0", "98.6", "", "", "", "", "96.9"]} +{"pcdb_id": 18775, "brand_name": "Ideal", "model_name": "EXCLUSIVE2", "model_qualifier": "35", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 70.3, "output_kw_max": 24.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0026, "loss_factor_f1_kwh_per_day": 1.40519, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018775", "000008", "0", "2020/Sep/22 18:04", "Ideal Boilers", "Ideal", "EXCLUSIVE2", "35", "47-349-64", "2019", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "89.0", "87.3", "", "70.3", "", "2", "", "", "104", "1", "2", "29", "3", "0", "", "", "", "0", "", "", "", "", "1", "7.495", "0.119", "0.0026", "1.40519", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.0", "98.6", "", "", "", "", "96.9"]} +{"pcdb_id": 18776, "brand_name": "Ideal", "model_name": "SERIES III GB", "model_qualifier": "24 PROPANE", "winter_efficiency_pct": 90.1, "summer_efficiency_pct": 89.3, "comparative_hot_water_efficiency_pct": 67.8, "output_kw_max": 24.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0031, "loss_factor_f1_kwh_per_day": 1.83121, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018776", "000008", "0", "2020/Sep/22 18:04", "Ideal Boilers", "Ideal", "SERIES III GB", "24 PROPANE", "", "2019", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "90.1", "89.3", "", "67.8", "", "2", "1", "", "104", "1", "2", "25", "3", "0", "", "", "", "0", "", "", "", "", "1", "7.937", "0.121", "0.0031", "1.83121", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "92.0", "100.8", "", "", "", "", "99.1"]} +{"pcdb_id": 18777, "brand_name": "Ideal", "model_name": "SERIES III GB", "model_qualifier": "30 PROPANE", "winter_efficiency_pct": 90.1, "summer_efficiency_pct": 89.3, "comparative_hot_water_efficiency_pct": 69.4, "output_kw_max": 24.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.003, "loss_factor_f1_kwh_per_day": 1.65818, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018777", "000008", "0", "2020/Sep/22 18:04", "Ideal Boilers", "Ideal", "SERIES III GB", "30 PROPANE", "", "2019", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "90.1", "89.3", "", "69.4", "", "2", "1", "", "104", "1", "2", "24", "3", "0", "", "", "", "0", "", "", "", "", "1", "7.758", "0.119", "0.003", "1.65818", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "92.0", "100.8", "", "", "", "", "99.1"]} +{"pcdb_id": 18778, "brand_name": "Morco", "model_name": "SERIES III GB", "model_qualifier": "24NG", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 70.0, "output_kw_max": 24.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0027, "loss_factor_f1_kwh_per_day": 1.43483, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018778", "000008", "0", "2020/Sep/22 18:04", "Ideal Boilers", "Morco", "SERIES III GB", "24NG", "", "2019", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "89.0", "87.3", "", "70.0", "", "2", "", "", "104", "1", "2", "42", "3", "0", "", "", "", "0", "", "", "", "", "1", "7.526", "0.12", "0.0027", "1.43483", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.0", "98.6", "", "", "", "", "96.9"]} +{"pcdb_id": 18779, "brand_name": "Morco", "model_name": "SERIES III GB", "model_qualifier": "30NG", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 69.5, "output_kw_max": 24.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0027, "loss_factor_f1_kwh_per_day": 1.48359, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018779", "000008", "0", "2020/Sep/22 18:04", "Ideal Boilers", "Morco", "SERIES III GB", "30NG", "", "2019", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "89.0", "87.3", "", "69.5", "", "2", "", "", "104", "1", "2", "32", "3", "0", "", "", "", "0", "", "", "", "", "1", "7.576", "0.119", "0.0027", "1.48359", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.0", "98.6", "", "", "", "", "96.9"]} +{"pcdb_id": 18780, "brand_name": "Morco", "model_name": "SERIES III GB", "model_qualifier": "24 PROPANE", "winter_efficiency_pct": 90.1, "summer_efficiency_pct": 89.3, "comparative_hot_water_efficiency_pct": 67.8, "output_kw_max": 24.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0031, "loss_factor_f1_kwh_per_day": 1.83121, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018780", "000008", "0", "2020/Sep/22 18:04", "Ideal Boilers", "Morco", "SERIES III GB", "24 PROPANE", "", "2019", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "90.1", "89.3", "", "67.8", "", "2", "1", "", "104", "1", "2", "25", "3", "0", "", "", "", "0", "", "", "", "", "1", "7.937", "0.121", "0.0031", "1.83121", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "92.0", "100.8", "", "", "", "", "99.1"]} +{"pcdb_id": 18781, "brand_name": "Morco", "model_name": "SERIES III GB", "model_qualifier": "30 PROPANE", "winter_efficiency_pct": 90.1, "summer_efficiency_pct": 89.3, "comparative_hot_water_efficiency_pct": 69.4, "output_kw_max": 24.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.003, "loss_factor_f1_kwh_per_day": 1.65818, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018781", "000008", "0", "2020/Sep/22 18:04", "Ideal Boilers", "Morco", "SERIES III GB", "30 PROPANE", "", "2019", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "", "", "90.1", "89.3", "", "69.4", "", "2", "1", "", "104", "1", "2", "24", "3", "0", "", "", "", "0", "", "", "", "", "1", "7.758", "0.119", "0.003", "1.65818", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "92.0", "100.8", "", "", "", "", "99.1"]} +{"pcdb_id": 18782, "brand_name": "Baxi", "model_name": "636 COMBI LPG", "model_qualifier": "", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 88.6, "comparative_hot_water_efficiency_pct": 79.8, "output_kw_max": 25.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0015, "loss_factor_f1_kwh_per_day": 0.64132, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018782", "000005", "0", "2020/Apr/15 09:20", "Baxi Heating", "Baxi", "636 COMBI LPG", "", "47-077-31", "2020", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "25.0", "25.0", "", "", "89.4", "88.6", "", "79.8", "", "2", "1", "", "104", "1", "2", "72", "3", "0", "", "", "", "0", "", "", "", "", "1", "6.748", "0.102", "0.0015", "0.64132", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "90.1", "100.0", "", "", "", "", "98.1"]} +{"pcdb_id": 18783, "brand_name": "Worcester", "model_name": "Greenstar 8000 Life", "model_qualifier": "GR8300iW 30 C LPG", "winter_efficiency_pct": 90.5, "summer_efficiency_pct": 88.9, "comparative_hot_water_efficiency_pct": 74.1, "output_kw_max": 29.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.008, "loss_factor_f1_kwh_per_day": 1.12085, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018783", "000035", "0", "2020/Jul/16 18:52", "Bosch Thermotechnology", "Worcester", "Greenstar 8000 Life", "GR8300iW 30 C LPG", "47-800-23", "2018", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "29.5", "29.5", "", "", "90.5", "88.9", "", "74.1", "", "2", "0", "", "104", "1", "2", "67", "1", "0", "", "", "", "0", "", "", "", "", "1", "7.261", "0.112", "0.008", "1.12085", "", "", "", "", "", "", "", "", "8325", "", "", "", "", "", "", "", "", "91.0", "99.7", "", "", "", "", "98.1"]} +{"pcdb_id": 18784, "brand_name": "Worcester", "model_name": "Greenstar 8000 Life", "model_qualifier": "GR8300iW 30 R LPG", "winter_efficiency_pct": 90.5, "summer_efficiency_pct": 81.5, "comparative_hot_water_efficiency_pct": 59.5, "output_kw_max": 29.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018784", "000035", "0", "2020/Apr/15 11:26", "Bosch Thermotechnology", "Worcester", "Greenstar 8000 Life", "GR8300iW 30 R LPG", "41-800-04", "2018", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "29.5", "29.5", "", "", "90.5", "81.5", "", "59.5", "", "2", "0", "", "102", "1", "2", "67", "1", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0305", "", "", "", "", "", "", "", "", "91.0", "99.7", "", "", "", "", "98.1"]} +{"pcdb_id": 18785, "brand_name": "Worcester", "model_name": "Greenstar 8000 Life", "model_qualifier": "GR8300iW 30 S LPG", "winter_efficiency_pct": 90.5, "summer_efficiency_pct": 81.5, "comparative_hot_water_efficiency_pct": 59.5, "output_kw_max": 29.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018785", "000035", "0", "2020/Apr/15 11:26", "Bosch Thermotechnology", "Worcester", "Greenstar 8000 Life", "GR8300iW 30 S LPG", "41-406-93", "2018", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "29.5", "29.5", "", "", "90.5", "81.5", "", "59.5", "", "2", "0", "", "102", "1", "2", "67", "1", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "8325", "", "", "", "", "", "", "", "", "91.0", "99.7", "", "", "", "", "98.1"]} +{"pcdb_id": 18786, "brand_name": "Worcester", "model_name": "Greenstar 8000 Life", "model_qualifier": "GR8300iW 35 C LPG", "winter_efficiency_pct": 90.5, "summer_efficiency_pct": 88.9, "comparative_hot_water_efficiency_pct": 74.9, "output_kw_max": 33.7, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.011, "loss_factor_f1_kwh_per_day": 1.02853, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018786", "000035", "0", "2020/Jul/16 18:54", "Bosch Thermotechnology", "Worcester", "Greenstar 8000 Life", "GR8300iW 35 C LPG", "47-800-22", "2018", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "33.7", "33.7", "", "", "90.5", "88.9", "", "74.9", "", "2", "0", "", "104", "1", "2", "48", "1", "0", "", "", "", "0", "", "", "", "", "1", "7.186", "0.109", "0.011", "1.02853", "", "", "", "", "", "", "", "", "8325", "", "", "", "", "", "", "", "", "90.9", "99.7", "", "", "", "", "98.1"]} +{"pcdb_id": 18787, "brand_name": "Worcester", "model_name": "Greenstar 8000 Life", "model_qualifier": "GR8300iW 35 R LPG", "winter_efficiency_pct": 90.5, "summer_efficiency_pct": 81.5, "comparative_hot_water_efficiency_pct": 59.5, "output_kw_max": 33.7, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018787", "000035", "0", "2020/Apr/15 11:27", "Bosch Thermotechnology", "Worcester", "Greenstar 8000 Life", "GR8300iW 35 R LPG", "41-800-03", "2018", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "33.7", "33.7", "", "", "90.5", "81.5", "", "59.5", "", "2", "0", "", "102", "1", "2", "48", "1", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0305", "", "", "", "", "", "", "", "", "90.9", "99.7", "", "", "", "", "98.1"]} +{"pcdb_id": 18788, "brand_name": "Worcester", "model_name": "Greenstar 8000 Life", "model_qualifier": "GR8300iW 35 S LPG", "winter_efficiency_pct": 90.5, "summer_efficiency_pct": 81.5, "comparative_hot_water_efficiency_pct": 59.5, "output_kw_max": 33.7, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018788", "000035", "0", "2020/Aug/11 15:50", "Bosch Thermotechnology", "Worcester", "Greenstar 8000 Life", "GR8300iW 35 S LPG", "41-406-92", "2018", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "33.7", "33.7", "", "", "90.5", "81.5", "", "59.5", "", "2", "0", "", "102", "1", "2", "48", "1", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "8325", "", "", "", "", "", "", "", "", "90.9", "99.7", "", "", "", "", "98.1"]} +{"pcdb_id": 18789, "brand_name": "Worcester", "model_name": "Greenstar 8000 Life", "model_qualifier": "GR8300iW 40 C LPG", "winter_efficiency_pct": 90.4, "summer_efficiency_pct": 88.9, "comparative_hot_water_efficiency_pct": 73.5, "output_kw_max": 33.7, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.01, "loss_factor_f1_kwh_per_day": 1.16904, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018789", "000035", "0", "2020/Jul/16 18:56", "Bosch Thermotechnology", "Worcester", "Greenstar 8000 Life", "GR8300iW 40 C LPG", "47-800-21", "2018", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "33.7", "33.7", "", "", "90.4", "88.9", "", "73.5", "", "2", "0", "", "104", "1", "2", "48", "1", "0", "", "", "", "0", "", "", "", "", "1", "7.323", "0.112", "0.01", "1.16904", "", "", "", "", "", "", "", "", "8325", "", "", "", "", "", "", "", "", "91.0", "99.6", "", "", "", "", "97.9"]} +{"pcdb_id": 18790, "brand_name": "Worcester", "model_name": "Greenstar 8000 Life", "model_qualifier": "GR8300iW 40 R LPG", "winter_efficiency_pct": 90.6, "summer_efficiency_pct": 81.6, "comparative_hot_water_efficiency_pct": 59.6, "output_kw_max": 40.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018790", "000035", "0", "2020/Apr/15 11:27", "Bosch Thermotechnology", "Worcester", "Greenstar 8000 Life", "GR8300iW 40 R LPG", "41-800-02", "2018", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "40.0", "40.0", "", "", "90.6", "81.6", "", "59.6", "", "2", "0", "", "102", "1", "2", "75", "1", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0305", "", "", "", "", "", "", "", "", "91.2", "99.8", "", "", "", "", "98.2"]} +{"pcdb_id": 18791, "brand_name": "Worcester", "model_name": "Greenstar 8000 Life", "model_qualifier": "GR8300iW 45 C LPG", "winter_efficiency_pct": 90.7, "summer_efficiency_pct": 89.1, "comparative_hot_water_efficiency_pct": 72.5, "output_kw_max": 33.7, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.002, "loss_factor_f1_kwh_per_day": 1.32645, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018791", "000035", "0", "2020/Jul/16 18:58", "Bosch Thermotechnology", "Worcester", "Greenstar 8000 Life", "GR8300iW 45 C LPG", "47-800-20", "2018", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "33.7", "33.7", "", "", "90.7", "89.1", "", "72.5", "", "2", "0", "", "104", "1", "2", "48", "1", "0", "", "", "", "0", "", "", "", "", "1", "7.425", "0.106", "0.002", "1.32645", "", "", "", "", "", "", "", "", "8325", "", "", "", "", "", "", "", "", "91.5", "100.2", "", "", "", "", "98.5"]} +{"pcdb_id": 18792, "brand_name": "Worcester", "model_name": "Greenstar 8000 Life", "model_qualifier": "GR8300iW 45 R LPG", "winter_efficiency_pct": 90.2, "summer_efficiency_pct": 81.2, "comparative_hot_water_efficiency_pct": 59.3, "output_kw_max": 42.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018792", "000035", "0", "2020/Apr/15 11:27", "Bosch Thermotechnology", "Worcester", "Greenstar 8000 Life", "GR8300iW 45 R LPG", "41-800-01", "2018", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "42", "42", "", "", "90.2", "81.2", "", "59.3", "", "2", "0", "", "102", "1", "2", "84", "1", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0305", "", "", "", "", "", "", "", "", "90.9", "98.9", "", "", "", "", "97.4"]} +{"pcdb_id": 18793, "brand_name": "Worcester", "model_name": "Greenstar 8000 Life", "model_qualifier": "GR8300iW 50 C LPG", "winter_efficiency_pct": 90.6, "summer_efficiency_pct": 89.1, "comparative_hot_water_efficiency_pct": 74.5, "output_kw_max": 33.7, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0025, "loss_factor_f1_kwh_per_day": 1.13294, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018793", "000035", "0", "2020/Jul/16 19:00", "Bosch Thermotechnology", "Worcester", "Greenstar 8000 Life", "GR8300iW 50 C LPG", "47-800-19", "2018", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "33.7", "33.7", "", "", "90.6", "89.1", "", "74.5", "", "2", "0", "", "104", "1", "2", "48", "1", "0", "", "", "", "0", "", "", "", "", "1", "7.228", "0.115", "0.0025", "1.13294", "", "", "", "", "", "", "", "", "8325", "", "", "", "", "", "", "", "", "91.5", "99.9", "", "", "", "", "98.3"]} +{"pcdb_id": 18794, "brand_name": "Worcester", "model_name": "Greenstar 8000 Life", "model_qualifier": "GR8300iW 50 R LPG", "winter_efficiency_pct": 90.3, "summer_efficiency_pct": 81.3, "comparative_hot_water_efficiency_pct": 59.4, "output_kw_max": 47.9, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018794", "000035", "0", "2020/Apr/15 11:28", "Bosch Thermotechnology", "Worcester", "Greenstar 8000 Life", "GR8300iW 50 R LPG", "41-406-99", "2018", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "47.9", "47.9", "", "", "90.3", "81.3", "", "59.4", "", "2", "0", "", "102", "1", "2", "84", "1", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0305", "", "", "", "", "", "", "", "", "90.8", "99.2", "", "", "", "", "97.6"]} +{"pcdb_id": 18795, "brand_name": "Alpha", "model_name": "E-Tec", "model_qualifier": "35S", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 32.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018795", "000001", "0", "2020/Jun/10 14:17", "Alpha Therm", "Alpha", "E-Tec", "35S", "3.028471", "2020", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "32", "32", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "42", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "1005", "", "", "", "", "", "", "", "", "88.1", "97.8", "", "", "", "", "95.9"]} +{"pcdb_id": 18796, "brand_name": "Alpha", "model_name": "E-Tec", "model_qualifier": "Plus 38", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 83.1, "comparative_hot_water_efficiency_pct": 75.7, "output_kw_max": 32.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.0004, "loss_factor_f1_kwh_per_day": 0.84825, "loss_factor_f2_kwh_per_day": 0.43872, "rejected_factor_f3_per_litre": -5e-05, "raw": ["018796", "000001", "0", "2020/Jun/10 14:16", "Alpha Therm", "Alpha", "E-Tec", "Plus 38", "3.028468", "2020", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "32", "32", "", "", "88.4", "83.1", "", "75.7", "", "2", "", "", "104", "1", "2", "42", "2", "0", "", "", "0.02", "0", "", "", "", "", "2", "6.956", "0.063", "0.0004", "0.84825", "13.316", "0.081", "0.0049", "0.43872", "-0.00005", "", "", "", "1005", "", "", "", "", "", "", "", "", "88.1", "97.8", "", "", "", "", "95.9"]} +{"pcdb_id": 18816, "brand_name": "Baxi", "model_name": "816 HEAT", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 16.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018816", "000005", "0", "2020/Jun/15 11:55", "Baxi Heating UK", "Baxi", "816 HEAT", "", "41-470-77", "2020", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "16", "16", "", "", "88.6", "79.6", "", "58.2", "", "2", "", "", "102", "1", "2", "20", " 0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "98.4", "", "", "", "", "96.4"]} +{"pcdb_id": 18817, "brand_name": "Baxi", "model_name": "825 HEAT", "model_qualifier": "", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 25.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018817", "000005", "0", "2020/Jun/15 11:56", "Baxi Heating UK", "Baxi", "825 HEAT", "", "41-470-78", "2020", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "25", "25", "", "", "88.6", "79.6", "", "58.2", "", "2", "", "", "102", "1", "2", "33", " 0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.0", "98.4", "", "", "", "", "96.4"]} +{"pcdb_id": 18818, "brand_name": "Baxi", "model_name": "830 HEAT", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 30.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018818", "000005", "0", "2020/Jun/15 11:56", "Baxi Heating UK", "Baxi", "830 HEAT", "", "41-470-79", "2020", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "30", "30", "", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "44", " 0", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.3", "98.0", "", "", "", "", "96.0"]} +{"pcdb_id": 18819, "brand_name": "Baxi", "model_name": "Platinum+", "model_qualifier": "32 System", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 32.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018819", "000005", "0", "2020/Jun/30 13:42", "Baxi Heating UK", "Baxi", "Platinum+", "32 System", "GC No. 41-470-95", "2020", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "32", "32", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "43", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "", "", "", "", "87.7", "96.9", "", "", "", "", "95.1"]} +{"pcdb_id": 18820, "brand_name": "Worcester", "model_name": "Greenstar 2000", "model_qualifier": "GR2300iW 25 C NG", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 88.2, "comparative_hot_water_efficiency_pct": 75.5, "output_kw_max": 20.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.0025, "loss_factor_f1_kwh_per_day": 0.84293, "loss_factor_f2_kwh_per_day": 0.82982, "rejected_factor_f3_per_litre": 1e-05, "raw": ["018820", "000035", "0", "2020/Aug/12 09:40", "Bosch Thermotechnology", "Worcester", "Greenstar 2000", "GR2300iW 25 C NG", "47-800-26", "2020", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "20", "20", "", "", "88.4", "88.2", "", "75.5", "", "2", "", "", "104", "1", "2", "28", "3", "0", "", "", "", "0", "", "", "", "", "2", "6.973", "0.077", "0.0025", "0.84293", "12.745", "0.098", "0.0015", "0.82982", "0.00001", "", "", "", "8305", "", "", "", "", "", "", "", "", "87.8", "98.0", "", "", "", "", "96.1"]} +{"pcdb_id": 18821, "brand_name": "Worcester", "model_name": "Greenstar 2000", "model_qualifier": "GR2300iW 30 C NG", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 88.0, "comparative_hot_water_efficiency_pct": 76.3, "output_kw_max": 20.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.005, "loss_factor_f1_kwh_per_day": 0.75911, "loss_factor_f2_kwh_per_day": 0.73376, "rejected_factor_f3_per_litre": 3e-05, "raw": ["018821", "000035", "0", "2020/Aug/12 09:54", "Bosch Thermotechnology", "Worcester", "Greenstar 2000", "GR2300iW 30 C NG", "47-800-28", "2020", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "20", "20", "", "", "88.4", "88.0", "", "76.3", "", "2", "", "", "104", "1", "2", "28", "3", "0", "", "", "", "0", "", "", "", "", "2", "6.901", "0.069", "0.005", "0.75911", "12.842", "0.101", "0.0021", "0.73376", "0.00003", "", "", "", "8305", "", "", "", "", "", "", "", "", "87.8", "98.0", "", "", "", "", "96.1"]} +{"pcdb_id": 18822, "brand_name": "Glow-worm", "model_name": "Energy7", "model_qualifier": "12r - A (H-GB)", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 12.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018822", "000207", "0", "2020/Aug/19 12:58", "Vaillant Group UK", "Glow-worm", "Energy7", "12r - A (H-GB)", "47-019-58", "2020", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "12.3", "12.3", "", "", "89.1", "80.1", "", "58.5", "", "2", "", "", "102", "1", "2", "19", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0085", "", "", "", "", "", "", "", "", "89.3", "99.0", "", "", "", "", "97.2"]} +{"pcdb_id": 18823, "brand_name": "Glow-worm", "model_name": "Energy7", "model_qualifier": "12s - A (H-GB)", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 12.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018823", "000207", "0", "2020/Aug/19 12:58", "Vaillant Group UK", "Glow-worm", "Energy7", "12s - A (H-GB)", "47-019-53", "2020", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "12.3", "12.3", "", "", "89.1", "80.1", "", "58.5", "", "2", "", "", "102", "1", "2", "19", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0085", "", "", "", "", "", "", "", "", "89.3", "99.0", "", "", "", "", "97.2"]} +{"pcdb_id": 18824, "brand_name": "Glow-worm", "model_name": "Energy7", "model_qualifier": "15r - A (H-GB)", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 15.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018824", "000207", "0", "2020/Aug/19 12:58", "Vaillant Group UK", "Glow-worm", "Energy7", "15r - A (H-GB)", "47-019-59", "2020", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "15.3", "15.3", "", "", "89.1", "80.1", "", "58.5", "", "2", "", "", "102", "1", "2", "19", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0085", "", "", "", "", "", "", "", "", "89.1", "99.1", "", "", "", "", "97.2"]} +{"pcdb_id": 18825, "brand_name": "Glow-worm", "model_name": "Energy7", "model_qualifier": "15s - A (H-GB)", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 15.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018825", "000207", "0", "2020/Aug/19 12:58", "Vaillant Group UK", "Glow-worm", "Energy7", "15s - A (H-GB)", "47-019-54", "2020", "current", "1", "2", "1", "1", "0", "", "", "2", "1", "2", "15.3", "15.3", "", "", "89.1", "80.1", "", "58.5", "", "2", "", "", "102", "1", "2", "37", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0085", "", "", "", "", "", "", "", "", "89.1", "99.1", "", "", "", "", "97.2"]} +{"pcdb_id": 18826, "brand_name": "Glow-worm", "model_name": "Energy7", "model_qualifier": "18r - A (H-GB)", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 18.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018826", "000207", "0", "2020/Aug/19 12:58", "Vaillant Group UK", "Glow-worm", "Energy7", "18r - A (H-GB)", "47-019-60", "2020", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18.4", "18.4", "", "", "89.0", "80.0", "", "58.4", "", "2", "", "", "102", "1", "2", "21", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0085", "", "", "", "", "", "", "", "", "89.0", "98.9", "", "", "", "", "97.0"]} +{"pcdb_id": 18827, "brand_name": "Glow-worm", "model_name": "Energy7", "model_qualifier": "18s - A (H-GB)", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 18.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018827", "000207", "0", "2020/Aug/19 12:58", "Vaillant Group UK", "Glow-worm", "Energy7", "18s - A (H-GB)", "47-019-55", "2020", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18.4", "18.4", "", "", "89.0", "80.0", "", "58.4", "", "2", "", "", "102", "1", "2", "21", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0085", "", "", "", "", "", "", "", "", "89.0", "98.9", "", "", "", "", "97.0"]} +{"pcdb_id": 18828, "brand_name": "Glow-worm", "model_name": "Energy7", "model_qualifier": "25r - A (H-GB)", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 24.7, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018828", "000207", "0", "2020/Aug/19 12:58", "Vaillant Group UK", "Glow-worm", "Energy7", "25r - A (H-GB)", "47-019-61", "2020", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24.7", "24.7", "", "", "89.1", "80.1", "", "58.5", "", "2", "", "", "102", "1", "2", "29", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0085", "", "", "", "", "", "", "", "", "89.2", "99.1", "", "", "", "", "97.2"]} +{"pcdb_id": 18829, "brand_name": "Glow-worm", "model_name": "Energy7", "model_qualifier": "25s - A (H-GB)", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 24.7, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018829", "000207", "0", "2020/Aug/19 12:58", "Vaillant Group UK", "Glow-worm", "Energy7", "25s - A (H-GB)", "47-019-56", "2020", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24.7", "24.7", "", "", "89.1", "80.1", "", "58.5", "", "2", "", "", "102", "1", "2", "29", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0085", "", "", "", "", "", "", "", "", "89.2", "99.1", "", "", "", "", "97.2"]} +{"pcdb_id": 18830, "brand_name": "Glow-worm", "model_name": "Energy7", "model_qualifier": "25c - A (H-GB)", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 78.9, "comparative_hot_water_efficiency_pct": 70.4, "output_kw_max": 18.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.0028, "loss_factor_f1_kwh_per_day": 1.36644, "loss_factor_f2_kwh_per_day": 0.56093, "rejected_factor_f3_per_litre": 3e-05, "raw": ["018830", "000207", "0", "2020/Aug/20 16:44", "Vaillant Group UK", "Glow-worm", "Energy7", "25c - A (H-GB)", "47-019-60", "2020", "current", "1", "2", "1", "2", "0", "", "", "2", "1", "2", "18.4", "18.4", "", "", "89.0", "78.9", "", "70.4", "", "2", "", "", "104", "1", "2", "21", "2", "0", "", "", "0", "0", "", "", "", "", "2", "7.484", "0.067", "0.0028", "1.36644", "14.1", "0.105", "0.0", "0.56093", "0.00003", "", "", "", "0085", "", "", "", "", "", "", "", "", "89.0", "98.9", "", "", "", "", "97.0"]} +{"pcdb_id": 18831, "brand_name": "Glow-worm", "model_name": "Energy7", "model_qualifier": "30r - A (H-GB)", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 35.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018831", "000207", "0", "2020/Aug/19 12:58", "Vaillant Group UK", "Glow-worm", "Energy7", "30r - A (H-GB)", "47-019-62", "2020", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "35", "35", "", "", "89.1", "80.1", "", "58.5", "", "2", "", "", "102", "1", "2", "29", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0085", "", "", "", "", "", "", "", "", "89.5", "98.9", "", "", "", "", "97.1"]} +{"pcdb_id": 18832, "brand_name": "Glow-worm", "model_name": "Energy7", "model_qualifier": "30s - A (H-GB)", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 35.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018832", "000207", "0", "2020/Aug/19 12:58", "Vaillant Group UK", "Glow-worm", "Energy7", "30s - A (H-GB)", "47-019-57", "2020", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "35", "35", "", "", "89.1", "80.1", "", "58.5", "", "2", "", "", "102", "1", "2", "37", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0085", "", "", "", "", "", "", "", "", "89.5", "98.9", "", "", "", "", "97.1"]} +{"pcdb_id": 18833, "brand_name": "Glow-worm", "model_name": "Energy7", "model_qualifier": "30c - A (H-GB)", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 83.9, "comparative_hot_water_efficiency_pct": 68.7, "output_kw_max": 24.7, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.0029, "loss_factor_f1_kwh_per_day": 1.54181, "loss_factor_f2_kwh_per_day": 1.1256, "rejected_factor_f3_per_litre": 3e-05, "raw": ["018833", "000207", "0", "2020/Aug/20 16:44", "Vaillant Group UK", "Glow-worm", "Energy7", "30c - A (H-GB)", "47-019-61", "2020", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.7", "24.7", "", "", "89.1", "83.9", "", "68.7", "", "2", "", "", "104", "1", "2", "21", "2", "0", "", "", "", "0", "", "", "", "", "2", "7.661", "0.067", "0.0029", "1.54181", "13.885", "0.094", "0.0", "1.1256", "0.00003", "", "", "", "0085", "", "", "", "", "", "", "", "", "89.2", "99.1", "", "", "", "", "97.2"]} +{"pcdb_id": 18834, "brand_name": "Glow-worm", "model_name": "Energy7", "model_qualifier": "35c - A (H-GB)", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 74.2, "comparative_hot_water_efficiency_pct": 76.1, "output_kw_max": 35.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.0045, "loss_factor_f1_kwh_per_day": 0.82431, "loss_factor_f2_kwh_per_day": 0.0, "rejected_factor_f3_per_litre": 5e-05, "raw": ["018834", "000207", "0", "2020/Aug/20 16:44", "Vaillant Group UK", "Glow-worm", "Energy7", "35c - A (H-GB)", "47-019-62", "2020", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "35", "35", "", "", "89.1", "74.2", "", "76.1", "", "2", "", "", "104", "1", "2", "29", "2", "0", "", "", "", "0", "", "", "", "", "2", "6.921", "0.096", "0.0045", "0.82431", "13.945", "0.114", "0.0", "0.0", "0.00005", "", "", "", "0085", "", "", "", "", "", "", "", "", "89.5", "98.9", "", "", "", "", "97.1"]} +{"pcdb_id": 18842, "brand_name": "E.C.A.", "model_name": "Confeo Premix P", "model_qualifier": "24 HCH NG ERP YBK UK", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 24.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018842", "000248", "0", "2020/Oct/20 10:02", "Emas Makina Sanayi", "E.C.A.", "Confeo Premix P", "24 HCH NG ERP YBK UK", "GC No 41-814-31", "2020", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24.5", "24.5", "", "", "88.1", "79.1", "", "57.8", "", "2", "", "", "102", "1", "2", "40", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "97.1", "", "", "", "", "95.3"]} +{"pcdb_id": 18843, "brand_name": "E.C.A.", "model_name": "Confeo Premix P", "model_qualifier": "24 HM NG ERP YBK UK", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 55.9, "output_kw_max": 24.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018843", "000248", "0", "2020/Oct/20 10:02", "Emas Makina Sanayi", "E.C.A.", "Confeo Premix P", "24 HM NG ERP YBK UK", "GC No 47-814-17", "2020", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.5", "24.5", "", "", "88.1", "79.5", "", "55.9", "", "2", "", "", "104", "1", "2", "40", "5", "0", "", "", "4.22", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "97.1", "", "", "", "", "95.3"]} +{"pcdb_id": 18844, "brand_name": "E.C.A.", "model_name": "Confeo Premix P", "model_qualifier": "24 HST NG ERP YBK UK", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 24.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018844", "000248", "0", "2020/Oct/20 10:02", "Emas Makina Sanayi", "E.C.A.", "Confeo Premix P", "24 HST NG ERP YBK UK", "GC No 41-814-37", "2020", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24.5", "24.5", "", "", "88.1", "79.1", "", "57.8", "", "2", "", "", "102", "1", "2", "40", "5", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "97.1", "", "", "", "", "95.3"]} +{"pcdb_id": 18845, "brand_name": "E.C.A.", "model_name": "Confeo Premix P", "model_qualifier": "28 HCH NG ERP YBK UK", "winter_efficiency_pct": 87.8, "summer_efficiency_pct": 78.8, "comparative_hot_water_efficiency_pct": 57.6, "output_kw_max": 28.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018845", "000248", "0", "2020/Oct/20 10:02", "Emas Makina Sanayi", "E.C.A.", "Confeo Premix P", "28 HCH NG ERP YBK UK", "GC No 41-814-32", "2020", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "28", "28", "", "", "87.8", "78.8", "", "57.6", "", "2", "", "", "102", "1", "2", "51", "4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.2", "96.7", "", "", "", "", "94.9"]} +{"pcdb_id": 18846, "brand_name": "E.C.A.", "model_name": "Confeo Premix P", "model_qualifier": "28 HM NG ERP YBK UK", "winter_efficiency_pct": 87.8, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 55.7, "output_kw_max": 28.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018846", "000248", "0", "2020/Oct/20 10:02", "Emas Makina Sanayi", "E.C.A.", "Confeo Premix P", "28 HM NG ERP YBK UK", "GC No 47-814-18", "2020", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28", "28", "", "", "87.8", "79.2", "", "55.7", "", "2", "", "", "104", "1", "2", "51", "4", "0", "", "", "5.02", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.2", "96.7", "", "", "", "", "94.9"]} +{"pcdb_id": 18847, "brand_name": "E.C.A.", "model_name": "Confeo Premix P", "model_qualifier": "28 HST NG ERP YBK UK", "winter_efficiency_pct": 87.8, "summer_efficiency_pct": 78.8, "comparative_hot_water_efficiency_pct": 57.6, "output_kw_max": 28.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018847", "000248", "0", "2020/Oct/20 10:03", "Emas Makina Sanayi", "E.C.A.", "Confeo Premix P", "28 HST NG ERP YBK UK", "GC No 41-814-38", "2020", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "28", "28", "", "", "87.8", "78.8", "", "57.6", "", "2", "", "", "102", "1", "2", "51", "4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.2", "96.7", "", "", "", "", "94.9"]} +{"pcdb_id": 18848, "brand_name": "E.C.A.", "model_name": "Confeo Premix P", "model_qualifier": "30 HCH NG ERP YBK UK", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 30.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018848", "000248", "0", "2020/Oct/20 10:03", "Emas Makina Sanayi", "E.C.A.", "Confeo Premix P", "30 HCH NG ERP YBK UK", "GC No 41-814-33", "2020", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "30", "30", "", "", "88.1", "79.1", "", "57.8", "", "2", "", "", "102", "1", "2", "56", "4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.5", "97.3", "", "", "", "", "95.4"]} +{"pcdb_id": 18849, "brand_name": "E.C.A.", "model_name": "Confeo Premix P", "model_qualifier": "30 HM NG ERP YBK UK", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 55.9, "output_kw_max": 30.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018849", "000248", "0", "2020/Oct/20 10:03", "Emas Makina Sanayi", "E.C.A.", "Confeo Premix P", "30 HM NG ERP YBK UK", "GC No 47-814-19", "2020", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "30", "30", "", "", "88.1", "79.5", "", "55.9", "", "2", "", "", "104", "1", "2", "56", "4", "0", "", "", "5.02", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.5", "97.3", "", "", "", "", "95.4"]} +{"pcdb_id": 18850, "brand_name": "E.C.A.", "model_name": "Confeo Premix P", "model_qualifier": "30 HST NG ERP YBK UK", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 30.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018850", "000248", "0", "2020/Oct/20 10:03", "Emas Makina Sanayi", "E.C.A.", "Confeo Premix P", "30 HST NG ERP YBK UK", "GC No 41-814-39", "2020", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "30", "30", "", "", "88.1", "79.1", "", "57.8", "", "2", "", "", "102", "1", "2", "56", "4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.5", "97.3", "", "", "", "", "95.4"]} +{"pcdb_id": 18851, "brand_name": "E.C.A.", "model_name": "Confeo Premix P", "model_qualifier": "35 HCH NG ERP YBK UK", "winter_efficiency_pct": 87.7, "summer_efficiency_pct": 78.7, "comparative_hot_water_efficiency_pct": 57.5, "output_kw_max": 35.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018851", "000248", "0", "2020/Oct/20 10:04", "Emas Makina Sanayi", "E.C.A.", "Confeo Premix P", "35 HCH NG ERP YBK UK", "GC No 41-814-34", "2020", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "35", "35", "", "", "87.7", "78.7", "", "57.5", "", "2", "", "", "102", "1", "2", "66", "4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.4", "96.4", "", "", "", "", "94.7"]} +{"pcdb_id": 18852, "brand_name": "E.C.A.", "model_name": "Confeo Premix P", "model_qualifier": "35 HM NG ERP YBK UK", "winter_efficiency_pct": 87.7, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 55.7, "output_kw_max": 35.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018852", "000248", "0", "2020/Oct/20 10:04", "Emas Makina Sanayi", "E.C.A.", "Confeo Premix P", "35 HM NG ERP YBK UK", "GC No 47-814-20", "2020", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "35", "35", "", "", "87.7", "79.1", "", "55.7", "", "2", "", "", "104", "1", "2", "66", "4", "0", "", "", "5.6", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.4", "96.4", "", "", "", "", "94.7"]} +{"pcdb_id": 18853, "brand_name": "E.C.A.", "model_name": "Confeo Premix P", "model_qualifier": "35 HST NG ERP YBK UK", "winter_efficiency_pct": 87.7, "summer_efficiency_pct": 78.7, "comparative_hot_water_efficiency_pct": 57.5, "output_kw_max": 35.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018853", "000248", "0", "2020/Oct/20 10:04", "Emas Makina Sanayi", "E.C.A.", "Confeo Premix P", "35 HST NG ERP YBK UK", "GC No 41-814-40", "2020", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "35", "35", "", "", "87.7", "78.7", "", "57.5", "", "2", "", "", "102", "1", "2", "66", "4", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.4", "96.4", "", "", "", "", "94.7"]} +{"pcdb_id": 18854, "brand_name": "Vokera BY RIELLO", "model_name": "Vision PLUS", "model_qualifier": "30C", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 56.1, "output_kw_max": 24.45, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018854", "000011", "0", "2020/Nov/02 11:27", "Vokera", "Vokera BY RIELLO", "Vision PLUS", "30C", "20173521", "2020", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.45", "24.45", "", "", "88.4", "79.8", "", "56.1", "", "2", "", "", "104", "1", "2", "38", "3", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.1", "97.8", "", "", "", "", "96.0"]} +{"pcdb_id": 18855, "brand_name": "Vokera BY RIELLO", "model_name": "Vision PLUS", "model_qualifier": "25C", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 56.1, "output_kw_max": 19.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018855", "000011", "0", "2020/Nov/02 11:29", "Vokera", "Vokera BY RIELLO", "Vision PLUS", "25C", "20173520", "2020", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "19.5", "19.5", "", "", "88.4", "79.8", "", "56.1", "", "2", "", "", "104", "1", "2", "29", "3", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "87.8", "97.8", "", "", "", "", "95.9"]} +{"pcdb_id": 18856, "brand_name": "Vokera BY RIELLO", "model_name": "Vision PLUS", "model_qualifier": "20S", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 79.0, "comparative_hot_water_efficiency_pct": 57.7, "output_kw_max": 19.46, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018856", "000011", "0", "2021/Jan/15 11:27", "Vokera", "Vokera BY RIELLO", "Vision PLUS", "20S", "20174726", "2020", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "19.46", "19.46", "", "", "88.0", "79.0", "", "57.7", "", "2", "", "", "102", "1", "2", "28", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "87.7", "96.9", "", "", "", "", "95.2"]} +{"pcdb_id": 18857, "brand_name": "Vokera BY RIELLO", "model_name": "Vision PLUS", "model_qualifier": "25S", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 24.38, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018857", "000011", "0", "2021/Jan/15 11:28", "Vokera", "Vokera BY RIELLO", "Vision PLUS", "25S", "20174728", "2020", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24.38", "24.38", "", "", "88.1", "79.1", "", "57.8", "", "2", "", "", "102", "1", "2", "30", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "87.8", "97.1", "", "", "", "", "95.4"]} +{"pcdb_id": 18858, "brand_name": "Vokera BY RIELLO", "model_name": "Vision PLUS", "model_qualifier": "30S", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 29.25, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018858", "000011", "0", "2021/Jan/15 11:28", "Vokera", "Vokera BY RIELLO", "Vision PLUS", "30S", "20174729", "2020", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "29.25", "29.25", "", "", "88.1", "79.1", "", "57.8", "", "2", "", "", "102", "1", "2", "41", "3", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "87.8", "97.1", "", "", "", "", "95.4"]} +{"pcdb_id": 18859, "brand_name": "Vokera BY RIELLO", "model_name": "Vision PLUS", "model_qualifier": "35C", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 55.9, "output_kw_max": 29.25, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018859", "000011", "0", "2021/Jan/15 11:28", "Vokera", "Vokera BY RIELLO", "Vision PLUS", "35C", "20174724", "2020", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "29.25", "29.25", "", "", "88.1", "79.5", "", "55.9", "", "2", "", "", "104", "1", "2", "41", "3", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "87.8", "97.1", "", "", "", "", "95.4"]} +{"pcdb_id": 18860, "brand_name": "Vokera BY RIELLO", "model_name": "Vision PLUS", "model_qualifier": "40C", "winter_efficiency_pct": 87.9, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 55.8, "output_kw_max": 29.25, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018860", "000011", "0", "2021/Jan/15 11:29", "Vokera", "Vokera BY RIELLO", "Vision PLUS", "40C", "20174725", "2020", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "29.25", "29.25", "", "", "87.9", "79.3", "", "55.8", "", "2", "", "", "104", "1", "2", "41", "3", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "", "", "", "", "87.8", "96.6", "", "", "", "", "94.9"]} +{"pcdb_id": 18863, "brand_name": "ATAG", "model_name": "A325EC", "model_qualifier": "X", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 85.2, "output_kw_max": 28.8, "final_year_of_manufacture": null, "subsidiary_type": 1, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0008, "loss_factor_f1_kwh_per_day": 0.13684, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018863", "000227", "0", "2021/Nov/29 13:53", "ATAG Verwarming Nederland BV", "ATAG", "A325EC", "X", "", "2010", "current", "1", "2", "1", "2", "1", "", "", "2", "3", "2", "28.8", "28.8", "", "", "89.1", "87.3", "", "85.2", "", "2", "", "", "104", "1", "2", "", "", "0", "", "", "", "0", "", "", "", "", "1", "6.18", "0.178", "0.0008", "0.13684", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.8", "98.8", "", "", "", "", "97.1"]} +{"pcdb_id": 18864, "brand_name": "Ideal", "model_name": "Logic Code Combi", "model_qualifier": "26", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 75.1, "output_kw_max": 24.2, "final_year_of_manufacture": 2013, "subsidiary_type": 1, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0048, "loss_factor_f1_kwh_per_day": 0.92126, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018864", "000008", "0", "2021/Nov/29 13:53", "Ideal Boilers", "Ideal", "Logic Code Combi", "26", "47-348-74", "2011", "2013", "1", "2", "1", "2", "1", "", "", "2", "2", "2", "24.2", "24.2", "", "", "88.4", "87.3", "", "75.1", "", "2", "", "", "104", "1", "2", "146", "1", "0", "", "", "0", "0", "", "", "", "", "1", "7.0133", "0.1547", "0.0048", "0.92126", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.8", "96.9", "", "", "", "", "95.6"]} +{"pcdb_id": 18865, "brand_name": "Ideal", "model_name": "Logic Code Combi", "model_qualifier": "33", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 75.8, "output_kw_max": 24.2, "final_year_of_manufacture": 2013, "subsidiary_type": 1, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0045, "loss_factor_f1_kwh_per_day": 0.86711, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018865", "000008", "0", "2021/Nov/29 13:53", "Ideal Boilers", "Ideal", "Logic Code Combi", "33", "47-348-75", "2011", "2013", "1", "2", "1", "2", "1", "", "", "2", "2", "2", "24.2", "24.2", "", "", "88.4", "87.3", "", "75.8", "", "2", "", "", "104", "1", "2", "152", "1", "0", "", "", "0", "0", "", "", "", "", "1", "6.9512", "0.1528", "0.0045", "0.86711", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "90.0", "96.9", "", "", "", "", "95.6"]} +{"pcdb_id": 18866, "brand_name": "Ideal", "model_name": "Logic Code Combi", "model_qualifier": "38", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 75.8, "output_kw_max": 24.2, "final_year_of_manufacture": 2013, "subsidiary_type": 1, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0082, "loss_factor_f1_kwh_per_day": 0.83483, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018866", "000008", "0", "2021/Nov/29 13:53", "Ideal Boilers", "Ideal", "Logic Code Combi", "38", "47-348-76", "2011", "2013", "1", "2", "1", "2", "1", "", "", "2", "2", "2", "24.2", "24.2", "", "", "88.3", "87.3", "", "75.8", "", "2", "", "", "104", "1", "2", "177", "1", "0", "", "", "0", "0", "", "", "", "", "1", "6.9449", "0.1539", "0.0082", "0.83483", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "89.8", "96.9", "", "", "", "", "95.5"]} +{"pcdb_id": 18867, "brand_name": "Alpha", "model_name": "InTec 30GS", "model_qualifier": "", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 80.6, "comparative_hot_water_efficiency_pct": 56.7, "output_kw_max": 18.3, "final_year_of_manufacture": null, "subsidiary_type": 1, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018867", "000001", "0", "2021/Nov/29 13:53", "Alpha Therm", "Alpha", "InTec 30GS", "", "", "2011", "current", "2", "2", "1", "2", "1", "313", "060085", "2", "2", "2", "18.3", "18.3", "", "", "89.2", "80.6", "", "56.7", "", "2", "1", "", "104", "1", "2", "120", "6", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "1005", "", "", "", "", "", "", "", "", "90.7", "99.1", "", "", "", "", "97.5"]} +{"pcdb_id": 18868, "brand_name": "Alpha", "model_name": "InTec 30GS", "model_qualifier": "", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 86.9, "comparative_hot_water_efficiency_pct": 81.0, "output_kw_max": 18.3, "final_year_of_manufacture": null, "subsidiary_type": 1, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0085, "loss_factor_f1_kwh_per_day": 0.37658, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018868", "000001", "0", "2021/Nov/29 13:53", "Alpha Therm", "Alpha", "InTec 30GS", "", "", "2011", "current", "1", "2", "1", "2", "1", "313", "060084", "2", "2", "2", "18.3", "18.3", "", "", "88.2", "86.9", "", "81.0", "", "2", "", "", "104", "1", "2", "120", "6", "0", "", "", "", "0", "", "", "", "", "1", "6.5", "0.147", "0.0085", "0.37658", "", "", "", "", "", "", "", "", "1005", "", "", "", "", "", "", "", "", "88.7", "96.9", "", "", "", "", "95.4"]} +{"pcdb_id": 18869, "brand_name": "Alpha", "model_name": "InTec 40GS", "model_qualifier": "", "winter_efficiency_pct": 89.3, "summer_efficiency_pct": 80.7, "comparative_hot_water_efficiency_pct": 56.8, "output_kw_max": 28.0, "final_year_of_manufacture": null, "subsidiary_type": 1, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018869", "000001", "0", "2021/Nov/29 13:53", "Alpha Therm", "Alpha", "InTec 40GS", "", "", "2011", "current", "2", "2", "1", "2", "1", "313", "060085", "2", "2", "2", "28", "28", "", "", "89.3", "80.7", "", "56.8", "", "2", "1", "", "104", "1", "2", "125", "6", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "1005", "", "", "", "", "", "", "", "", "91.4", "99.2", "", "", "", "", "97.7"]} +{"pcdb_id": 18870, "brand_name": "Alpha", "model_name": "InTec 40GS", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 87.1, "comparative_hot_water_efficiency_pct": 79.4, "output_kw_max": 28.0, "final_year_of_manufacture": null, "subsidiary_type": 1, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.007, "loss_factor_f1_kwh_per_day": 0.52692, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018870", "000001", "0", "2021/Nov/29 13:53", "Alpha Therm", "Alpha", "InTec 40GS", "", "", "2011", "current", "1", "2", "1", "2", "1", "313", "060084", "2", "2", "2", "28", "28", "", "", "88.3", "87.1", "", "79.4", "", "2", "", "", "104", "1", "2", "125", "6", "0", "", "", "", "0", "", "", "", "", "1", "6.631", "0.121", "0.007", "0.52692", "", "", "", "", "", "", "", "", "1005", "", "", "", "", "", "", "", "", "89.4", "97.0", "", "", "", "", "95.6"]} +{"pcdb_id": 18871, "brand_name": "Alpha", "model_name": "InTec 40 GS2", "model_qualifier": "", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 98.9, "comparative_hot_water_efficiency_pct": 81.0, "output_kw_max": 28.0, "final_year_of_manufacture": null, "subsidiary_type": 1, "store_type": 0, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.0035, "loss_factor_f1_kwh_per_day": 0.42069, "loss_factor_f2_kwh_per_day": 1.1267, "rejected_factor_f3_per_litre": 2e-05, "raw": ["018871", "000001", "0", "2021/Nov/29 13:53", "Alpha Therm", "Alpha", "InTec 40 GS2", "", "3.028276", "2017", "current", "1", "2", "1", "2", "1", "313", "060086", "2", "2", "2", "28.0", "28.0", "", "", "88.3", "98.9", "", "81.0", "", "2", "", "", "104", "1", "2", "37", "6", "0", "", "", "", "0", "", "", "", "", "2", "6.5", "0.208", "0.0035", "0.42069", "11.79", "0.23", "0.0015", "1.1267", "0.00002", "", "", "", "1005", "", "", "", "", "", "", "", "", "89.4", "97.0", "", "", "", "", "95.6"]} +{"pcdb_id": 18872, "brand_name": "ATAG", "model_name": "IC Economiser Plus 35", "model_qualifier": "", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 97.8, "comparative_hot_water_efficiency_pct": 79.9, "output_kw_max": 28.3, "final_year_of_manufacture": null, "subsidiary_type": 1, "store_type": 0, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.0013, "loss_factor_f1_kwh_per_day": 0.50098, "loss_factor_f2_kwh_per_day": 1.1609, "rejected_factor_f3_per_litre": 1e-05, "raw": ["018872", "000299", "0", "2021/Nov/29 13:53", "ATAG Verwarming Nederland BV", "ATAG", "IC Economiser Plus 35", "", "", "2018", "current", "1", "2", "1", "2", "1", "", "", "2", "3", "2", "28.3", "28.3", "", "", "89.1", "97.8", "", "79.9", "", "2", "", "", "104", "1", "2", "74", "4", "0", "", "", "", "0", "", "", "", "", "2", "6.59", "0.168", "0.0013", "0.50098", "11.94", "0.183", "0.0007", "1.1609", "0.00001", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.6", "99.5", "", "", "", "", "97.4"]} +{"pcdb_id": 18873, "brand_name": "ATAG", "model_name": "IC Economiser Plus 39", "model_qualifier": "", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 97.8, "comparative_hot_water_efficiency_pct": 79.9, "output_kw_max": 28.3, "final_year_of_manufacture": null, "subsidiary_type": 1, "store_type": 0, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.0013, "loss_factor_f1_kwh_per_day": 0.50098, "loss_factor_f2_kwh_per_day": 1.1609, "rejected_factor_f3_per_litre": 1e-05, "raw": ["018873", "000299", "0", "2021/Nov/29 13:53", "ATAG Verwarming Nederland BV", "ATAG", "IC Economiser Plus 39", "", "", "2018", "current", "1", "2", "1", "2", "1", "", "", "2", "3", "2", "28.3", "28.3", "", "", "89.1", "97.8", "", "79.9", "", "2", "", "", "104", "1", "2", "74", "4", "0", "", "", "", "0", "", "", "", "", "2", "6.59", "0.168", "0.0013", "0.50098", "11.94", "0.183", "0.0007", "1.1609", "0.00001", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.6", "99.5", "", "", "", "", "97.4"]} +{"pcdb_id": 18900, "brand_name": "Warmhaus", "model_name": "Ewa", "model_qualifier": "2530 C 30 KW", "winter_efficiency_pct": 84.4, "summer_efficiency_pct": 75.8, "comparative_hot_water_efficiency_pct": 59.1, "output_kw_max": 23.7, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018900", "020152", "0", "2021/Mar/25 10:06", "Warmhaus Isitma ve Sogutma Sistemleri Sanayi", "Warmhaus", "Ewa", "2530 C 30 KW", "8699104832925", "2019", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "23.7", "23.7", "A", "", "84.4", "75.8", "", "59.1", "", "2", "", "", "104", "2", "2", "43", "5", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "", "", "0005", "", "A", "84", "XL", "92", "11", "79", "57.0", "88.3", "97.6", "", "", "", "", "95.8"]} +{"pcdb_id": 18901, "brand_name": "Warmhaus", "model_name": "Minerwa", "model_qualifier": "2500 HO 25 KW", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 23.7, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018901", "020152", "0", "2021/Mar/25 10:07", "Warmhaus Isitma ve Sogutma Sistemleri Sanayi", "Warmhaus", "Minerwa", "2500 HO 25 KW", "8699104832949", "2020", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "23.7", "23.7", "A", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "43", "5", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "92", "11", "79", "27.0", "88.3", "97.6", "", "", "", "", "95.8"]} +{"pcdb_id": 18902, "brand_name": "Warmhaus", "model_name": "Ewa", "model_qualifier": "2525 C 25 KW", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 62.3, "output_kw_max": 23.7, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018902", "020152", "0", "2021/Mar/25 10:08", "Warmhaus Isitma ve Sogutma Sistemleri Sanayi", "Warmhaus", "Ewa", "2525 C 25 KW", "8699104832918", "2019", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "23.7", "23.7", "A", "", "88.4", "79.8", "", "62.3", "", "2", "", "", "104", "1", "2", "43", "5", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "", "", "0005", "", "A", "84", "XL", "92", "11", "79", "57.0", "88.3", "97.6", "", "", "", "", "95.8"]} +{"pcdb_id": 18903, "brand_name": "Worcester", "model_name": "Greenstar 2000", "model_qualifier": "GR2300iW 25 C LPG", "winter_efficiency_pct": 90.0, "summer_efficiency_pct": 90.3, "comparative_hot_water_efficiency_pct": 77.1, "output_kw_max": 20.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.003, "loss_factor_f1_kwh_per_day": 0.85226, "loss_factor_f2_kwh_per_day": 0.84514, "rejected_factor_f3_per_litre": 3e-05, "raw": ["018903", "020051", "0", "2021/Apr/28 09:50", "Bosch Thermotechnology Ltd", "Worcester", "Greenstar 2000", "GR2300iW 25 C LPG", "47-800-27", "2021", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "20", "20", "A", "", "90.0", "90.3", "", "77.1", "", "2", "0", "2", "104", "1", "2", "28", "3", "0", "", "", "", "0", "", "", "", "", "2", "6.981", "0.086", "0.003", "0.85226", "12.311", "0.104", "0.0", "0.84514", "0.00003", "0", "", "", "8305", "", "A", "84", "XL", "93", "11", "58", "55.0", "89.9", "98.9", "", "018820", "", "", "97.2"]} +{"pcdb_id": 18904, "brand_name": "Worcester", "model_name": "Greenstar 2000", "model_qualifier": "GR2300iW 30 C LPG", "winter_efficiency_pct": 90.0, "summer_efficiency_pct": 90.3, "comparative_hot_water_efficiency_pct": 76.1, "output_kw_max": 20.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.0045, "loss_factor_f1_kwh_per_day": 0.93294, "loss_factor_f2_kwh_per_day": 0.92573, "rejected_factor_f3_per_litre": 5e-05, "raw": ["018904", "020051", "0", "2021/Apr/28 09:45", "Bosch Thermotechnology Ltd", "Worcester", "Greenstar 2000", "GR2300iW 30 C LPG", "47-800-29", "2021", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "20", "20", "A", "", "90.0", "90.3", "", "76.1", "", "2", "0", "2", "104", "1", "2", "28", "3", "0", "", "", "", "0", "", "", "", "", "2", "7.074", "0.083", "0.0045", "0.93294", "12.496", "0.104", "0.0", "0.92573", "0.00005", "0", "", "", "8305", "", "A", "84", "XL", "93", "11", "58", "55.0", "89.9", "98.9", "", "018821", "", "", "97.2"]} +{"pcdb_id": 18905, "brand_name": "Sapphire", "model_name": "Sapphire 28", "model_qualifier": "", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 81.1, "comparative_hot_water_efficiency_pct": 59.2, "output_kw_max": 28.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018905", "020153", "0", "2021/Apr/27 10:27", "EOGB Energy Products ltd", "Sapphire", "Sapphire 28", "", "", "2021", "current", "4", "1", "1", "1", "0", "", "", "2", "2", "2", "28", "28", "A", "", "88.9", "81.1", "", "59.2", "", "2", "", "", "201", "1", "2", "117", "6.22", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "4015", "", "", "", "", "93", "27.1", "164", "49.4", "91.5", "96.8", "", "", "", "", "95.8"]} +{"pcdb_id": 18906, "brand_name": "Sapphire", "model_name": "Sapphire 23", "model_qualifier": "", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 80.9, "comparative_hot_water_efficiency_pct": 59.1, "output_kw_max": 23.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018906", "020153", "0", "2021/May/10 09:22", "EOGB Energy Products ltd", "Sapphire", "Sapphire 23", "", "", "2021", "current", "4", "1", "1", "1", "0", "", "", "2", "2", "2", "23", "23", "A", "", "88.7", "80.9", "", "59.1", "", "2", "", "", "201", "1", "2", "133", "6", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "4015", "", "", "", "", "92", "27", "172", "49.0", "92.6", "95.9", "", "", "", "", "95.2"]} +{"pcdb_id": 18907, "brand_name": "Worcester", "model_name": "Greenstar 4000", "model_qualifier": "GR4700iW 30 C NG", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 87.6, "comparative_hot_water_efficiency_pct": 74.2, "output_kw_max": 24.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.0004, "loss_factor_f1_kwh_per_day": 0.98328, "loss_factor_f2_kwh_per_day": 0.91574, "rejected_factor_f3_per_litre": 0.0, "raw": ["018907", "020051", "0", "2021/Jun/15 14:05", "Bosch Thermotechnology Ltd", "Worcester", "Greenstar 4000", "GR4700iW 30 C NG", "47-800-32", "2021", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "A", "", "88.7", "87.6", "", "74.2", "", "2", "", "", "104", "1", "2", "38.8", "2.44", "0", "", "", "", "0", "", "", "", "", "2", "7.099", "0.109", "0.0004", "0.98328", "13.078", "0.134", "0.0004", "0.91574", "0.0", "0", "", "", "C305", "", "A", "85", "XL", "94", "13.1", "66", "61.0", "88.0", "98.6", "", "", "", "", "96.6"]} +{"pcdb_id": 18908, "brand_name": "Worcester", "model_name": "Greenstar 4000", "model_qualifier": "GR4700iW 25 C NG", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 88.2, "comparative_hot_water_efficiency_pct": 73.8, "output_kw_max": 24.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.0008, "loss_factor_f1_kwh_per_day": 1.01462, "loss_factor_f2_kwh_per_day": 0.99421, "rejected_factor_f3_per_litre": 0.0, "raw": ["018908", "020051", "0", "2021/Jun/15 14:06", "Bosch Thermotechnology Ltd", "Worcester", "Greenstar 4000", "GR4700iW 25 C NG", "47-800-30", "2021", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "A", "", "88.7", "88.2", "", "73.8", "", "2", "", "", "104", "1", "2", "38.8", "2.44", "0", "", "", "", "0", "", "", "", "", "2", "7.134", "0.11", "0.0008", "1.01462", "12.918", "0.134", "0.0004", "0.99421", "0.0", "0", "", "", "C305", "", "A", "85", "XL", "94", "13.1", "66", "61.0", "88.0", "98.6", "", "", "", "", "96.6"]} +{"pcdb_id": 18909, "brand_name": "Worcester", "model_name": "Greenstar 4000", "model_qualifier": "GR4700iW 24 S NG", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 24.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018909", "020051", "0", "2021/Jun/11 17:28", "Bosch Thermotechnology Ltd", "Worcester", "Greenstar 4000", "GR4700iW 24 S NG", "41-800-15", "2021", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24", "24", "A", "", "88.7", "79.7", "", "58.2", "", "2", "", "", "102", "1", "2", "38", "2.44", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "C305", "", "", "", "", "94", "11.8", "62", "59.0", "88.0", "98.6", "", "", "", "", "96.6"]} +{"pcdb_id": 18910, "brand_name": "Worcester", "model_name": "Greenstar 4000", "model_qualifier": "GR4700iW 21 S NG", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 21.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018910", "020051", "0", "2021/Jun/11 17:43", "Bosch Thermotechnology Ltd", "Worcester", "Greenstar 4000", "GR4700iW 21 S NG", "41-800-13", "2021", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "21", "21", "A", "", "88.9", "79.9", "", "58.4", "", "2", "", "", "102", "1", "2", "30", "2.44", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "C305", "", "", "", "", "94", "11.2", "56", "59.0", "88.1", "99.0", "", "", "", "", "96.9"]} +{"pcdb_id": 18911, "brand_name": "Worcester", "model_name": "Greenstar 4000", "model_qualifier": "GR4700iW 18 S NG", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 18.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018911", "020051", "0", "2021/Jun/11 16:56", "Bosch Thermotechnology Ltd", "Worcester", "Greenstar 4000", "GR4700iW 18 S NG", "41-800-11", "2021", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18", "18", "A", "", "88.8", "79.8", "", "58.3", "", "2", "", "", "102", "1", "2", "27", "2.44", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "C305", "", "", "", "", "94", "11", "54", "59.0", "88.0", "98.8", "", "", "", "", "96.8"]} +{"pcdb_id": 18912, "brand_name": "Worcester", "model_name": "Greenstar 4000", "model_qualifier": "GR4700iW 15 S NG", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 15.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018912", "020051", "0", "2021/Jun/11 16:46", "Bosch Thermotechnology Ltd", "Worcester", "Greenstar 4000", "GR4700iW 15 S NG", "41-800-09", "2021", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "15", "15", "A", "", "89.1", "80.1", "", "58.5", "", "2", "", "", "102", "1", "2", "31.3", "2.44", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "C305", "", "", "", "", "94", "11.3", "57", "59.0", "88.5", "99.3", "", "", "", "", "97.2"]} +{"pcdb_id": 18913, "brand_name": "Worcester", "model_name": "Greenstar 4000", "model_qualifier": "GR4700iW 12 S NG", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 12.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018913", "020051", "0", "2021/Jun/11 16:42", "Bosch Thermotechnology Ltd", "Worcester", "Greenstar 4000", "GR4700iW 12 S NG", "41-800-07", "2021", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "12", "12", "A", "", "89.1", "80.1", "", "58.5", "", "2", "", "", "102", "1", "2", "22.8", "2.44", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "C305", "", "", "", "", "94", "10.6", "51", "59.0", "88.5", "99.5", "", "", "", "", "97.4"]} +{"pcdb_id": 18914, "brand_name": "E.C.A", "model_name": "FELiS FL 50 HM NG GB", "model_qualifier": "Condensing Boiler", "winter_efficiency_pct": 87.8, "summer_efficiency_pct": 78.8, "comparative_hot_water_efficiency_pct": 57.6, "output_kw_max": 45.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018914", "020162", "0", "2021/Aug/05 09:49", "Emas Makina Sanayi AS", "E.C.A", "FELiS FL 50 HM NG GB", "Condensing Boiler", "41-814-41", "2021", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "45.6", "45.6", "A", "", "87.8", "78.8", "", "57.6", "", "2", "", "", "102", "1", "2", "75", "4", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "95", "16", "102", "411.0", "86.2", "97.1", "", "", "", "", "95.1"]} +{"pcdb_id": 18915, "brand_name": "E.C.A", "model_name": "FELiS FL 65 HM NG GB", "model_qualifier": "", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 66.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018915", "020162", "0", "2021/Oct/13 09:09", "Emas Makina Sanayi AS", "E.C.A", "FELiS FL 65 HM NG GB", "", "41-814-42", "2021", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "66", "66", "A", "", "88.1", "79.1", "", "57.8", "", "2", "", "", "102", "1", "2", "115", "4", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "95", "22", "138", "939.0", "87.4", "97.3", "", "", "", "", "95.4"]} +{"pcdb_id": 18916, "brand_name": "Worcester", "model_name": "Greenstar 4000", "model_qualifier": "GR4700iW 30 C LPG", "winter_efficiency_pct": 89.8, "summer_efficiency_pct": 89.4, "comparative_hot_water_efficiency_pct": 75.1, "output_kw_max": 24.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.0, "loss_factor_f1_kwh_per_day": 1.04497, "loss_factor_f2_kwh_per_day": 0.97381, "rejected_factor_f3_per_litre": 0.0, "raw": ["018916", "020051", "0", "2021/Oct/12 13:17", "Bosch Thermotechnology Ltd", "Worcester", "Greenstar 4000", "GR4700iW 30 C LPG", "47-800-33", "2021", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "A", "", "89.8", "89.4", "", "75.1", "", "2", "0", "2", "104", "1", "2", "39", "2", "0", "", "", "", "0", "", "", "", "", "2", "7.168", "0.108", "0.0", "1.04497", "13.158", "0.131", "0.0004", "0.97381", "0.0", "0", "", "", "C305", "", "A", "85", "XL", "94", "13", "63", "61.0", "89.7", "98.5", "", "", "", "", "96.8"]} +{"pcdb_id": 18917, "brand_name": "Worcester", "model_name": "Greenstar 4000", "model_qualifier": "GR4700iW 25 C LPG", "winter_efficiency_pct": 89.8, "summer_efficiency_pct": 90.3, "comparative_hot_water_efficiency_pct": 73.3, "output_kw_max": 24.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.0008, "loss_factor_f1_kwh_per_day": 1.20857, "loss_factor_f2_kwh_per_day": 1.20588, "rejected_factor_f3_per_litre": 0.0, "raw": ["018917", "020051", "0", "2021/Oct/12 13:08", "Bosch Thermotechnology Ltd", "Worcester", "Greenstar 4000", "GR4700iW 25 C LPG", "47-800-32", "2021", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "A", "", "89.8", "90.3", "", "73.3", "", "2", "0", "2", "104", "1", "2", "38.8", "2.44", "0", "", "", "", "0", "", "", "", "", "2", "7.343", "0.109", "0.0008", "1.20857", "13.262", "0.132", "0.0004", "1.20588", "0.0", "0", "", "", "C305", "", "A", "85", "XL", "94", "13.1", "66", "61.0", "89.7", "98.5", "", "", "", "", "96.8"]} +{"pcdb_id": 18918, "brand_name": "Worcester", "model_name": "Greenstar 4000", "model_qualifier": "GR4700iW 24 S LPG", "winter_efficiency_pct": 89.8, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 59.0, "output_kw_max": 24.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018918", "020051", "0", "2021/Oct/12 13:00", "Bosch Thermotechnology Ltd", "Worcester", "Greenstar 4000", "GR4700iW 24 S LPG", "41-800-16", "2021", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "24", "24", "A", "", "89.8", "80.8", "", "59.0", "", "2", "0", "2", "102", "1", "2", "38", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "C305", "", "", "", "", "94", "12", "60", "59.0", "89.7", "98.5", "", "", "", "", "96.8"]} +{"pcdb_id": 18919, "brand_name": "Worcester", "model_name": "Greenstar 4000", "model_qualifier": "GR4700iW 21 S LPG", "winter_efficiency_pct": 89.9, "summer_efficiency_pct": 80.9, "comparative_hot_water_efficiency_pct": 59.1, "output_kw_max": 21.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018919", "020051", "0", "2021/Oct/12 12:24", "Bosch Thermotechnology Ltd", "Worcester", "Greenstar 4000", "GR4700iW 21 S LPG", "41-800-14", "2021", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "21", "21", "A", "", "89.9", "80.9", "", "59.1", "", "2", "0", "2", "102", "1", "2", "30", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "C305", "", "", "", "", "94", "11", "53", "59.0", "90.0", "98.5", "", "", "", "", "96.9"]} +{"pcdb_id": 18920, "brand_name": "Worcester", "model_name": "Greenstar 4000", "model_qualifier": "GR4700iW 18 S LPG", "winter_efficiency_pct": 89.9, "summer_efficiency_pct": 80.9, "comparative_hot_water_efficiency_pct": 59.1, "output_kw_max": 18.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018920", "020051", "0", "2021/Oct/12 12:06", "Bosch Thermotechnology Ltd", "Worcester", "Greenstar 4000", "GR4700iW 18 S LPG", "41-800-12", "2021", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "18", "18", "A", "", "89.9", "80.9", "", "59.1", "", "2", "0", "2", "102", "1", "2", "27", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "C305", "", "", "", "", "94", "11", "52", "59.0", "90.0", "98.7", "", "", "", "", "97.1"]} +{"pcdb_id": 18921, "brand_name": "Worcester", "model_name": "Greenstar 4000", "model_qualifier": "GR4700iW 15 S LPG", "winter_efficiency_pct": 90.0, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 59.2, "output_kw_max": 15.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018921", "020051", "0", "2021/Oct/12 12:06", "Bosch Thermotechnology Ltd", "Worcester", "Greenstar 4000", "GR4700iW 15 S LPG", "41-800-10", "2021", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "15", "15", "A", "", "90.0", "81.0", "", "59.2", "", "2", "0", "2", "102", "1", "2", "31", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "C305", "", "", "", "", "94", "11", "54", "59.0", "89.8", "98.9", "", "", "", "", "97.2"]} +{"pcdb_id": 18922, "brand_name": "Worcester", "model_name": "Greenstar 4000", "model_qualifier": "GR4700iW 12 S LPG", "winter_efficiency_pct": 90.0, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 59.2, "output_kw_max": 12.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018922", "020051", "0", "2021/Oct/12 11:35", "Bosch Thermotechnology Ltd", "Worcester", "Greenstar 4000", "GR4700iW 12 S LPG", "41-800-08", "2021", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "12", "12", "A", "", "90.0", "81.0", "", "59.2", "", "2", "0", "2", "102", "1", "2", "23", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "C305", "", "", "", "", "94", "11", "49", "59.0", "90.0", "99.0", "", "", "", "", "97.3"]} +{"pcdb_id": 18923, "brand_name": "Viessmann", "model_name": "VITODENS 200-W", "model_qualifier": "B2HF-11", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 10.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018923", "020094", "0", "2021/Nov/26 14:42", "Viessmann Ltd", "Viessmann", "VITODENS 200-W", "B2HF-11", "B2HF", "2020", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "10", "10", "A", "", "88.3", "79.3", "", "58.0", "", "2", "", "", "102", "1", "2", "16", "4.7", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "92", "15", "70", "52.5", "88.2", "97.6", "", "", "", "", "95.8"]} +{"pcdb_id": 18924, "brand_name": "Viessmann", "model_name": "VITODENS 200-W", "model_qualifier": "B2HF-11", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 10.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018924", "020094", "0", "2021/Nov/26 14:43", "Viessmann Ltd", "Viessmann", "VITODENS 200-W", "B2HF-11", "B2HF11", "2020", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "10", "10", "A", "", "89.2", "80.2", "", "58.6", "", "2", "0", "2", "102", "1", "2", "16", "4.7", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "92", "15", "70", "52.5", "90.0", "97.0", "", "", "", "", "95.7"]} +{"pcdb_id": 18925, "brand_name": "Viessmann", "model_name": "VITODENS 200-W", "model_qualifier": "B2HF-19", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 18.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018925", "020094", "0", "2021/Nov/26 14:45", "Viessmann Ltd", "Viessmann", "VITODENS 200-W", "B2HF-19", "B2HF19", "2020", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18", "18", "A", "", "88.5", "79.5", "", "58.0", "", "2", "", "", "102", "1", "2", "17", "4.7", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "93", "15", "71", "52.5", "88.5", "97.8", "", "", "", "", "96.0"]} +{"pcdb_id": 18926, "brand_name": "Viessmann", "model_name": "VITODENS 200-W", "model_qualifier": "B2HF-19", "winter_efficiency_pct": 89.5, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 58.8, "output_kw_max": 18.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018926", "020094", "0", "2021/Nov/26 14:48", "Viessmann Ltd", "Viessmann", "VITODENS 200-W", "B2HF-19", "B2HF19", "2020", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "18", "18", "A", "", "89.5", "80.5", "", "58.8", "", "2", "0", "2", "102", "1", "2", "17", "4.7", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "93", "15", "71", "52.5", "90.2", "97.4", "", "", "", "", "96.1"]} +{"pcdb_id": 18927, "brand_name": "Viessmann", "model_name": "VITODENS 200-W", "model_qualifier": "B2HF-25", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 23.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018927", "020094", "0", "2021/Nov/26 14:50", "Viessmann Ltd", "Viessmann", "VITODENS 200-W", "B2HF-25", "B2HF25", "2020", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "23", "23", "A", "", "88.6", "79.6", "", "58.2", "", "2", "", "", "102", "1", "2", "19", "4.7", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "94", "16", "74", "52.5", "88.5", "98.2", "", "", "", "", "96.4"]} +{"pcdb_id": 18928, "brand_name": "Viessmann", "model_name": "VITODENS 200-W", "model_qualifier": "B2HF-25", "winter_efficiency_pct": 89.5, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 58.8, "output_kw_max": 23.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018928", "020094", "0", "2021/Nov/26 14:51", "Viessmann Ltd", "Viessmann", "VITODENS 200-W", "B2HF-25", "B2HF25", "2020", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "23", "23", "A", "", "89.5", "80.5", "", "58.8", "", "2", "0", "2", "102", "1", "2", "19", "4.7", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "94", "16", "74", "52.5", "90.3", "97.6", "", "", "", "", "96.2"]} +{"pcdb_id": 18929, "brand_name": "Viessmann", "model_name": "VITODENS 200-W", "model_qualifier": "B2HF-32", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 29.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018929", "020094", "0", "2021/Nov/26 14:56", "Viessmann Ltd", "Viessmann", "VITODENS 200-W", "B2HF-32", "B2HF32", "2020", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "29", "29", "A", "", "88.5", "79.5", "", "58.1", "", "2", "", "", "102", "1", "2", "21", "4.7", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "94", "16", "75", "52.5", "88.2", "98.0", "", "", "", "", "96.2"]} +{"pcdb_id": 18930, "brand_name": "Viessmann", "model_name": "VITODENS 200-W", "model_qualifier": "B2HF-32", "winter_efficiency_pct": 89.6, "summer_efficiency_pct": 80.6, "comparative_hot_water_efficiency_pct": 58.9, "output_kw_max": 29.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018930", "020094", "0", "2021/Nov/26 14:57", "Viessmann Ltd", "Viessmann", "VITODENS 200-W", "B2HF-32", "B2HF32", "2020", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "29", "29", "A", "", "89.6", "80.6", "", "58.9", "", "2", "0", "2", "102", "1", "2", "21", "4.7", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "94", "16", "75", "52.5", "90.1", "97.9", "", "", "", "", "96.4"]} +{"pcdb_id": 18931, "brand_name": "Viessmann", "model_name": "VITODENS 200-W", "model_qualifier": "B2KF-25", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 87.6, "comparative_hot_water_efficiency_pct": 70.6, "output_kw_max": 23.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.0049, "loss_factor_f1_kwh_per_day": 1.31296, "loss_factor_f2_kwh_per_day": 1.22773, "rejected_factor_f3_per_litre": 3e-05, "raw": ["018931", "020094", "0", "2021/Nov/26 14:26", "Viessmann Ltd", "Viessmann", "VITODENS 200-W", "B2KF-25", "B2KF25", "2020", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "23", "23", "A", "", "88.6", "87.6", "", "70.6", "", "2", "", "", "104", "1", "2", "19", "4.7", "0", "", "", "", "0", "", "", "", "", "2", "7.456", "0.159", "0.0049", "1.31296", "13.425", "0.179", "0.0017", "1.22773", "0.00003", "0", "", "", "0005", "", "A", "82", "XL", "94", "16", "74", "52.5", "88.5", "98.2", "", "", "", "", "96.4"]} +{"pcdb_id": 18932, "brand_name": "Viessmann", "model_name": "VITODENS 200-W", "model_qualifier": "B2KF-25", "winter_efficiency_pct": 89.5, "summer_efficiency_pct": 89.2, "comparative_hot_water_efficiency_pct": 72.3, "output_kw_max": 23.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.0031, "loss_factor_f1_kwh_per_day": 1.30705, "loss_factor_f2_kwh_per_day": 1.20558, "rejected_factor_f3_per_litre": 1e-05, "raw": ["018932", "020094", "0", "2021/Nov/26 14:25", "Viessmann Ltd", "Viessmann", "VITODENS 200-W", "B2KF-25", "B2KF25", "2020", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "23", "23", "A", "", "89.5", "89.2", "", "72.3", "", "2", "0", "2", "104", "1", "2", "19", "4.7", "0", "", "", "", "0", "", "", "", "", "2", "7.444", "0.158", "0.0031", "1.30705", "13.443", "0.178", "0.0018", "1.20558", "0.00001", "0", "", "", "0005", "", "A", "82", "XL", "94", "16", "74", "52.5", "90.3", "97.6", "", "", "", "", "96.2"]} +{"pcdb_id": 18933, "brand_name": "Viessmann", "model_name": "VITODENS 200-W", "model_qualifier": "B2KF-32", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 73.3, "output_kw_max": 29.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.0006, "loss_factor_f1_kwh_per_day": 1.07341, "loss_factor_f2_kwh_per_day": 0.34805, "rejected_factor_f3_per_litre": 0.0, "raw": ["018933", "020094", "0", "2022/May/16 20:56", "Viessmann Ltd", "Viessmann", "VITODENS 200-W", "B2KF-32", "B2KF32", "2020", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "29", "29", "A", "", "88.5", "79.2", "", "73.3", "", "2", "", "", "104", "1", "2", "21", "4.7", "0", "", "", "", "0", "", "", "", "", "2", "7.189", "0.176", "0.0006", "1.07341", "13.802", "0.2", "0.0009", "0.34805", "0.0", "0", "", "", "0005", "", "A", "82", "XL", "94", "16", "75", "52.5", "88.2", "98.0", "", "", "", "", "96.2"]} +{"pcdb_id": 18934, "brand_name": "Viessmann", "model_name": "VITODENS 200-W", "model_qualifier": "B2KF-32", "winter_efficiency_pct": 89.6, "summer_efficiency_pct": 81.7, "comparative_hot_water_efficiency_pct": 72.9, "output_kw_max": 29.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.0025, "loss_factor_f1_kwh_per_day": 1.25178, "loss_factor_f2_kwh_per_day": 0.56403, "rejected_factor_f3_per_litre": 2e-05, "raw": ["018934", "020094", "0", "2021/Nov/26 14:29", "Viessmann Ltd", "Viessmann", "VITODENS 200-W", "B2KF-32", "B2KF32", "2020", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "29", "29", "A", "", "89.6", "81.7", "", "72.9", "", "2", "0", "2", "104", "1", "2", "21", "4.7", "0", "", "", "", "0", "", "", "", "", "2", "7.388", "0.17", "0.0025", "1.25178", "13.926", "0.2", "0.0004", "0.56403", "0.00002", "0", "", "", "0005", "", "A", "82", "XL", "94", "16", "75", "52.5", "90.1", "97.9", "", "", "", "", "96.4"]} +{"pcdb_id": 18935, "brand_name": "Viessmann", "model_name": "VITODENS 222-F", "model_qualifier": "B2TF-19", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 88.2, "comparative_hot_water_efficiency_pct": 59.4, "output_kw_max": 18.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.0001, "loss_factor_f1_kwh_per_day": 2.70647, "loss_factor_f2_kwh_per_day": 2.66659, "rejected_factor_f3_per_litre": 0.0, "raw": ["018935", "020094", "0", "2021/Nov/23 16:01", "Viessmann Ltd", "Viessmann", "VITODENS 222-F", "B2TF-19", "B2TF19", "2020", "current", "1", "1", "1", "2", "0", "", "", "2", "2", "2", "18", "18", "A", "", "88.5", "88.2", "", "59.4", "", "2", "", "", "106", "1", "2", "17", "4.7", "2", "2", "0", "100", "0", "", "2", "", "", "2", "8.873", "0.217", "0.0001", "2.70647", "14.519", "0.247", "0.0", "2.66659", "0.0", "", "", "", "0005", "", "A", "80", "XL", "93", "15", "71", "69.1", "88.5", "97.8", "", "", "", "", "96.0"]} +{"pcdb_id": 18936, "brand_name": "Viessmann", "model_name": "VITODENS 222F", "model_qualifier": "B2TF-19", "winter_efficiency_pct": 89.5, "summer_efficiency_pct": 90.3, "comparative_hot_water_efficiency_pct": 60.3, "output_kw_max": 18.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.0001, "loss_factor_f1_kwh_per_day": 2.75679, "loss_factor_f2_kwh_per_day": 2.73891, "rejected_factor_f3_per_litre": 0.0, "raw": ["018936", "020094", "0", "2021/Nov/23 16:07", "Viessmann Ltd", "Viessmann", "VITODENS 222F", "B2TF-19", "B2TF19", "2020", "current", "2", "1", "1", "2", "0", "", "", "2", "2", "2", "18", "18", "A", "", "89.5", "90.3", "", "60.3", "", "2", "0", "2", "106", "1", "2", "17", "4.7", "2", "2", "0", "100", "0", "", "2", "", "", "2", "8.934", "0.206", "0.0001", "2.75679", "14.806", "0.253", "0.0", "2.73891", "0.0", "", "", "", "0005", "", "A", "80", "XL", "93", "15", "71", "69.1", "90.2", "97.4", "", "", "", "", "96.1"]} +{"pcdb_id": 18937, "brand_name": "Viessmann", "model_name": "VITODENS 222-F", "model_qualifier": "B2TF-25", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 86.9, "comparative_hot_water_efficiency_pct": 60.9, "output_kw_max": 23.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.0003, "loss_factor_f1_kwh_per_day": 2.48488, "loss_factor_f2_kwh_per_day": 2.32738, "rejected_factor_f3_per_litre": 0.0, "raw": ["018937", "020094", "0", "2021/Nov/23 16:18", "Viessmann Ltd", "Viessmann", "VITODENS 222-F", "B2TF-25", "B2TF25", "2020", "current", "1", "1", "1", "2", "0", "", "", "2", "2", "2", "23", "23", "A", "", "88.7", "86.9", "", "60.9", "", "2", "", "", "106", "1", "2", "19", "4.7", "2", "2", "0", "100", "0", "", "2", "", "", "2", "8.644", "0.187", "0.0003", "2.48488", "14.665", "0.215", "0.0001", "2.32738", "0.0", "", "", "", "0005", "", "A", "80", "XL", "93", "16", "74", "69.1", "88.5", "98.4", "", "", "", "", "96.5"]} +{"pcdb_id": 18938, "brand_name": "Viessmann", "model_name": "VITODENS 222-F", "model_qualifier": "B2TF-25", "winter_efficiency_pct": 89.5, "summer_efficiency_pct": 90.3, "comparative_hot_water_efficiency_pct": 61.9, "output_kw_max": 23.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.0003, "loss_factor_f1_kwh_per_day": 2.52931, "loss_factor_f2_kwh_per_day": 2.50906, "rejected_factor_f3_per_litre": 0.0, "raw": ["018938", "020094", "0", "2021/Nov/11 14:52", "Viessmann Ltd", "Viessmann", "VITODENS 222-F", "B2TF-25", "B2TF25", "2020", "current", "2", "1", "1", "2", "0", "", "", "2", "2", "2", "23", "23", "A", "", "89.5", "90.3", "", "61.9", "", "2", "0", "2", "106", "1", "2", "19", "4.7", "2", "2", "0", "100", "0", "", "2", "", "", "2", "8.696", "0.188", "0.0003", "2.52931", "14.616", "0.214", "0.0002", "2.50906", "0.0", "", "", "", "0005", "", "A", "80", "XL", "94", "16", "74", "69.1", "90.3", "97.6", "", "", "", "", "96.2"]} +{"pcdb_id": 18939, "brand_name": "Viessmann", "model_name": "VITODENS 222-F", "model_qualifier": "B2TF-32", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 84.1, "comparative_hot_water_efficiency_pct": 63.2, "output_kw_max": 29.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.0005, "loss_factor_f1_kwh_per_day": 2.17289, "loss_factor_f2_kwh_per_day": 1.77651, "rejected_factor_f3_per_litre": 0.0, "raw": ["018939", "020094", "0", "2021/Nov/23 16:18", "Viessmann Ltd", "Viessmann", "VITODENS 222-F", "B2TF-32", "B2TF32", "2020", "current", "1", "1", "1", "2", "0", "", "", "2", "2", "2", "29", "29", "A", "", "88.5", "84.1", "", "63.2", "", "2", "", "", "106", "1", "2", "21", "4.7", "2", "2", "0", "100", "0", "", "2", "", "", "2", "8.33", "0.174", "0.0005", "2.17289", "14.55", "0.205", "0.0002", "1.77651", "0.0", "", "", "", "0005", "", "A", "80", "XL", "94", "16", "75", "69.1", "88.2", "98.0", "", "", "", "", "96.2"]} +{"pcdb_id": 18940, "brand_name": "Viessmann", "model_name": "VITODENS 222-F", "model_qualifier": "B2TF-32", "winter_efficiency_pct": 89.6, "summer_efficiency_pct": 80.6, "comparative_hot_water_efficiency_pct": 63.6, "output_kw_max": 29.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 1, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.0005, "loss_factor_f1_kwh_per_day": 2.2953, "loss_factor_f2_kwh_per_day": 1.40973, "rejected_factor_f3_per_litre": 0.0, "raw": ["018940", "020094", "0", "2021/Nov/23 16:21", "Viessmann Ltd", "Viessmann", "VITODENS 222-F", "B2TF-32", "B2TF32", "2020", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "29", "29", "A", "", "89.6", "80.6", "", "63.6", "", "2", "0", "2", "106", "1", "2", "21", "4.7", "1", "2", "0", "100", "0", "", "2", "", "", "2", "8.46", "0.175", "0.0005", "2.2953", "15.097", "0.2", "0.0002", "1.40973", "0.0", "", "", "", "0005", "", "A", "80", "XL", "94", "16", "75", "69.1", "90.1", "97.9", "", "", "", "", "96.4"]} +{"pcdb_id": 18941, "brand_name": "Viessmann", "model_name": "VITODENS 100-W", "model_qualifier": "B1KF-26", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 88.2, "comparative_hot_water_efficiency_pct": 69.8, "output_kw_max": 23.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.0011, "loss_factor_f1_kwh_per_day": 1.4097, "loss_factor_f2_kwh_per_day": 1.3832, "rejected_factor_f3_per_litre": 0.0, "raw": ["018941", "020094", "0", "2022/Jan/14 15:41", "Viessmann Ltd", "Viessmann", "VITODENS 100-W", "B1KF-26", "", "2021", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "23", "23", "A", "", "88.7", "88.2", "", "69.8", "", "2", "", "", "104", "1", "2", "18", "3.8", "0", "", "", "", "0", "", "", "", "", "2", "7.541", "0.157", "0.0011", "1.4097", "13.475", "0.175", "0.0013", "1.3832", "0.0", "1", "1", "", "00020005", "", "A", "82", "XL", "94", "15", "66", "57.3", "88.2", "98.5", "", "", "", "", "96.5"]} +{"pcdb_id": 18942, "brand_name": "Viessmann", "model_name": "VITODENS 100-W", "model_qualifier": "B1KF-35", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 85.2, "comparative_hot_water_efficiency_pct": 70.1, "output_kw_max": 29.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.001, "loss_factor_f1_kwh_per_day": 1.37662, "loss_factor_f2_kwh_per_day": 1.11648, "rejected_factor_f3_per_litre": 0.0, "raw": ["018942", "020094", "0", "2022/Jan/14 15:41", "Viessmann Ltd", "Viessmann", "VITODENS 100-W", "B1KF-35", "", "2021", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "29.3", "29.3", "A", "", "88.5", "85.2", "", "70.1", "", "2", "", "", "104", "1", "2", "21", "3.8", "0", "", "", "", "0", "", "", "", "", "2", "7.514", "0.2", "0.001", "1.37662", "13.657", "0.224", "0.0007", "1.11648", "0.0", "1", "1", "", "00020005", "", "A", "82", "XL", "94", "16", "70", "57.3", "87.9", "98.2", "", "", "", "", "96.3"]} +{"pcdb_id": 18943, "brand_name": "Viessmann", "model_name": "VITODENS 100-W", "model_qualifier": "B1KF-26", "winter_efficiency_pct": 89.6, "summer_efficiency_pct": 90.3, "comparative_hot_water_efficiency_pct": 70.2, "output_kw_max": 23.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.0027, "loss_factor_f1_kwh_per_day": 1.507, "loss_factor_f2_kwh_per_day": 1.50921, "rejected_factor_f3_per_litre": 0.0, "raw": ["018943", "020094", "0", "2022/Jan/14 15:44", "Viessmann Ltd", "Viessmann", "VITODENS 100-W", "B1KF-26", "", "2021", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "23", "23", "A", "", "89.6", "90.3", "", "70.2", "", "2", "0", "2", "104", "1", "2", "18", "3.8", "0", "", "", "", "0", "", "", "", "", "2", "7.67", "0.16", "0.0027", "1.507", "13.604", "0.176", "0.0023", "1.50921", "0.0", "1", "1", "", "00020005", "", "A", "82", "XL", "94", "15", "66", "57.3", "89.5", "98.1", "", "", "", "", "96.5"]} +{"pcdb_id": 18944, "brand_name": "Viessmann", "model_name": "VITODENS 100-W", "model_qualifier": "B1KF-35", "winter_efficiency_pct": 89.8, "summer_efficiency_pct": 89.2, "comparative_hot_water_efficiency_pct": 69.6, "output_kw_max": 29.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.0049, "loss_factor_f1_kwh_per_day": 1.56598, "loss_factor_f2_kwh_per_day": 1.46408, "rejected_factor_f3_per_litre": 5e-05, "raw": ["018944", "020094", "0", "2022/Jan/14 15:45", "Viessmann Ltd", "Viessmann", "VITODENS 100-W", "B1KF-35", "", "2021", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "29.3", "29.3", "A", "", "89.8", "89.2", "", "69.6", "", "2", "0", "2", "104", "1", "2", "21", "3.8", "0", "", "", "", "0", "", "", "", "", "2", "7.729", "0.202", "0.0049", "1.56598", "13.701", "0.227", "0.0003", "1.46408", "0.00005", "1", "1", "", "00020005", "", "A", "82", "XL", "94", "16", "70", "57.3", "90.1", "98.3", "", "", "", "", "96.7"]} +{"pcdb_id": 18945, "brand_name": "Viessmann", "model_name": "VITODENS 100-W", "model_qualifier": "B1KF-30", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 88.1, "comparative_hot_water_efficiency_pct": 69.8, "output_kw_max": 23.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.0025, "loss_factor_f1_kwh_per_day": 1.40315, "loss_factor_f2_kwh_per_day": 1.36515, "rejected_factor_f3_per_litre": 2e-05, "raw": ["018945", "020094", "0", "2022/Jan/14 15:47", "Viessmann Ltd", "Viessmann", "VITODENS 100-W", "B1KF-30", "", "2021", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "23", "23", "A", "", "88.7", "88.1", "", "69.8", "", "2", "", "", "104", "1", "2", "18", "3.8", "0", "", "", "", "0", "", "", "", "", "2", "7.543", "0.16", "0.0025", "1.40315", "13.481", "0.177", "0.0007", "1.36515", "0.00002", "1", "1", "", "00020005", "", "A", "82", "XL", "94", "15", "66", "57.3", "88.2", "98.5", "", "", "", "", "96.5"]} +{"pcdb_id": 18946, "brand_name": "Viessmann", "model_name": "VITODENS 100-W", "model_qualifier": "B1KF-30", "winter_efficiency_pct": 89.6, "summer_efficiency_pct": 90.3, "comparative_hot_water_efficiency_pct": 70.8, "output_kw_max": 23.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.001, "loss_factor_f1_kwh_per_day": 1.44788, "loss_factor_f2_kwh_per_day": 1.45255, "rejected_factor_f3_per_litre": 0.0, "raw": ["018946", "020094", "0", "2022/Jan/14 15:49", "Viessmann Ltd", "Viessmann", "VITODENS 100-W", "B1KF-30", "", "2021", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "23", "23", "A", "", "89.6", "90.3", "", "70.8", "", "2", "0", "2", "104", "1", "2", "18", "3.8", "0", "", "", "", "0", "", "", "", "", "2", "7.601", "0.16", "0.001", "1.44788", "13.501", "0.178", "0.0012", "1.45255", "0.0", "1", "1", "", "00020005", "", "A", "82", "XL", "94", "15", "66", "57.3", "89.4", "98.1", "", "", "", "", "96.4"]} +{"pcdb_id": 18947, "brand_name": "Viessmann", "model_name": "VITODENS 100-W", "model_qualifier": "B1KF-30-M", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 88.1, "comparative_hot_water_efficiency_pct": 69.8, "output_kw_max": 23.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.0025, "loss_factor_f1_kwh_per_day": 1.40315, "loss_factor_f2_kwh_per_day": 1.36515, "rejected_factor_f3_per_litre": 2e-05, "raw": ["018947", "020094", "0", "2022/Jan/14 15:50", "Viessmann Ltd", "Viessmann", "VITODENS 100-W", "B1KF-30-M", "", "2021", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "23", "23", "A", "", "88.7", "88.1", "", "69.8", "", "2", "", "", "104", "1", "2", "18", "3.8", "0", "", "", "", "0", "", "", "", "", "2", "7.543", "0.16", "0.0025", "1.40315", "13.481", "0.177", "0.0007", "1.36515", "0.00002", "1", "1", "", "00020005", "", "A", "82", "XL", "94", "15", "66", "57.3", "88.2", "98.5", "", "", "", "", "96.5"]} +{"pcdb_id": 18948, "brand_name": "Viessmann", "model_name": "VITODENS 100-W", "model_qualifier": "B1HF-11", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 10.1, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018948", "020094", "0", "2022/Jan/14 15:56", "Viessmann Ltd", "Viessmann", "VITODENS 100-W", "B1HF-11", "", "2021", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "10.1", "10.1", "A", "", "88.8", "79.8", "", "58.3", "", "2", "", "", "102", "1", "2", "17", "3.8", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "00020005", "", "", "", "", "93", "15", "65", "57.3", "88.4", "98.7", "", "", "", "", "96.7"]} +{"pcdb_id": 18949, "brand_name": "Viessmann", "model_name": "VITODENS 100-W", "model_qualifier": "B1HF-11", "winter_efficiency_pct": 89.7, "summer_efficiency_pct": 80.7, "comparative_hot_water_efficiency_pct": 59.0, "output_kw_max": 10.1, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018949", "020094", "0", "2022/Jan/14 15:57", "Viessmann Ltd", "Viessmann", "VITODENS 100-W", "B1HF-11", "", "2021", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "10.1", "10.1", "A", "", "89.7", "80.7", "", "59.0", "", "2", "0", "2", "102", "1", "2", "17", "3.8", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "00020005", "", "", "", "", "93", "15", "65", "57.3", "90.1", "98.2", "", "", "", "", "96.6"]} +{"pcdb_id": 18950, "brand_name": "Viessmann", "model_name": "VITODENS 100-W", "model_qualifier": "B1HF-11-M", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 10.1, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018950", "020094", "0", "2022/Jan/14 15:58", "Viessmann Ltd", "Viessmann", "VITODENS 100-W", "B1HF-11-M", "", "2021", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "10.1", "10.1", "A", "", "88.8", "79.8", "", "58.3", "", "2", "", "", "102", "1", "2", "17", "3.8", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "00020005", "", "", "", "", "93", "15", "65", "57.3", "88.4", "98.7", "", "", "", "", "96.7"]} +{"pcdb_id": 18951, "brand_name": "Viessmann", "model_name": "VITODENS 100-W", "model_qualifier": "B1HF-19", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 17.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018951", "020094", "0", "2022/Jan/14 16:00", "Viessmann Ltd", "Viessmann", "VITODENS 100-W", "B1HF-19", "", "2021", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "17.5", "17.5", "A", "", "88.8", "79.8", "", "58.3", "", "2", "", "", "102", "1", "2", "17", "3.8", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "00020005", "", "", "", "", "93", "14", "63", "57.3", "88.3", "98.7", "", "", "", "", "96.7"]} +{"pcdb_id": 18952, "brand_name": "Viessmann", "model_name": "VITODENS 100-W", "model_qualifier": "B1HF-25", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 23.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018952", "020094", "0", "2022/Jan/14 16:08", "Viessmann Ltd", "Viessmann", "VITODENS 100-W", "B1HF-25", "", "2021", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "23", "23", "A", "", "88.7", "79.7", "", "58.2", "", "2", "", "", "102", "1", "2", "18", "3.8", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "00020005", "", "", "", "", "94", "15", "66", "57.3", "88.2", "98.5", "", "", "", "", "96.5"]} +{"pcdb_id": 18953, "brand_name": "Viessmann", "model_name": "VITODENS 100-W", "model_qualifier": "B1HF-25", "winter_efficiency_pct": 89.6, "summer_efficiency_pct": 80.6, "comparative_hot_water_efficiency_pct": 58.9, "output_kw_max": 23.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018953", "020094", "0", "2022/Jan/14 16:10", "Viessmann Ltd", "Viessmann", "VITODENS 100-W", "B1HF-25", "", "2021", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "23", "23", "A", "", "89.6", "80.6", "", "58.9", "", "2", "0", "2", "102", "1", "2", "18", "3.8", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "00020005", "", "", "", "", "94", "15", "66", "57.3", "89.5", "98.1", "", "", "", "", "96.5"]} +{"pcdb_id": 18954, "brand_name": "Viessmann", "model_name": "VITODENS 100-W", "model_qualifier": "B1HF-32", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 29.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018954", "020094", "0", "2022/Jan/14 16:12", "Viessmann Ltd", "Viessmann", "VITODENS 100-W", "B1HF-32", "", "2021", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "29.3", "29.3", "A", "", "88.5", "79.5", "", "58.1", "", "2", "", "", "102", "1", "2", "21", "3.8", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "00020005", "", "", "", "", "94", "16", "70", "57.3", "87.9", "98.2", "", "", "", "", "96.3"]} +{"pcdb_id": 18955, "brand_name": "Viessmann", "model_name": "VITODENS 100-W", "model_qualifier": "B1HF-32", "winter_efficiency_pct": 89.8, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 59.0, "output_kw_max": 29.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018955", "020094", "0", "2022/Jan/14 16:13", "Viessmann Ltd", "Viessmann", "VITODENS 100-W", "B1HF-32", "", "2021", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "29.3", "29.3", "A", "", "89.8", "80.8", "", "59.0", "", "2", "0", "2", "102", "1", "2", "21", "3.8", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "00020005", "", "", "", "", "94", "16", "70", "57.3", "90.1", "98.3", "", "", "", "", "96.7"]} +{"pcdb_id": 18956, "brand_name": "Viessmann", "model_name": "VITODENS 111-W", "model_qualifier": "B1LF-25", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 87.7, "comparative_hot_water_efficiency_pct": 60.3, "output_kw_max": 23.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.0008, "loss_factor_f1_kwh_per_day": 2.55917, "loss_factor_f2_kwh_per_day": 2.48557, "rejected_factor_f3_per_litre": 0.0, "raw": ["018956", "020094", "0", "2022/Jan/24 12:25", "Viessmann Ltd", "Viessmann", "VITODENS 111-W", "B1LF-25", "", "2021", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "23", "23", "A", "", "88.7", "87.7", "", "60.3", "", "2", "", "", "106", "1", "2", "18", "3.8", "2", "2", "0", "46", "0", "", "2", "", "", "2", "8.733", "0.18", "0.0008", "2.55917", "14.699", "0.203", "0.0004", "2.48557", "0.0", "", "", "", "00020005", "", "A", "80", "XL", "94", "15", "66", "76.3", "88.2", "98.5", "", "", "", "", "96.5"]} +{"pcdb_id": 18957, "brand_name": "Viessmann", "model_name": "VITODENS 111-W", "model_qualifier": "B1LF-25", "winter_efficiency_pct": 89.6, "summer_efficiency_pct": 87.1, "comparative_hot_water_efficiency_pct": 61.3, "output_kw_max": 23.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.0006, "loss_factor_f1_kwh_per_day": 2.58424, "loss_factor_f2_kwh_per_day": 2.28751, "rejected_factor_f3_per_litre": 0.0, "raw": ["018957", "020094", "0", "2022/Jan/24 12:26", "Viessmann Ltd", "Viessmann", "VITODENS 111-W", "B1LF-25", "", "2021", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "23", "23", "A", "", "89.6", "87.1", "", "61.3", "", "2", "0", "2", "106", "1", "2", "18", "3.8", "2", "2", "0", "46", "0", "", "2", "", "", "2", "8.779", "0.175", "0.0006", "2.58424", "14.924", "0.199", "0.0004", "2.28751", "0.0", "", "", "", "00020005", "", "A", "80", "XL", "94", "15", "66", "76.3", "89.5", "98.1", "", "", "", "", "96.5"]} +{"pcdb_id": 18958, "brand_name": "Viessmann", "model_name": "VITODENS 111-W", "model_qualifier": "B1LF-M-25", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 87.7, "comparative_hot_water_efficiency_pct": 60.3, "output_kw_max": 23.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.0008, "loss_factor_f1_kwh_per_day": 2.55917, "loss_factor_f2_kwh_per_day": 2.48557, "rejected_factor_f3_per_litre": 0.0, "raw": ["018958", "020094", "0", "2022/Jan/24 12:26", "Viessmann Ltd", "Viessmann", "VITODENS 111-W", "B1LF-M-25", "", "2021", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "23", "23", "A", "", "88.7", "87.7", "", "60.3", "", "2", "", "", "106", "1", "2", "18", "3.8", "2", "2", "0", "46", "0", "", "2", "", "", "2", "8.733", "0.18", "0.0008", "2.55917", "14.699", "0.203", "0.0004", "2.48557", "0.0", "", "", "", "00020005", "", "A", "80", "XL", "94", "15", "66", "76.3", "88.2", "98.5", "", "", "", "", "96.5"]} +{"pcdb_id": 18959, "brand_name": "Viessmann", "model_name": "VITODENS 111-W", "model_qualifier": "B1LF-32", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 88.2, "comparative_hot_water_efficiency_pct": 61.8, "output_kw_max": 29.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.0004, "loss_factor_f1_kwh_per_day": 2.34902, "loss_factor_f2_kwh_per_day": 2.32744, "rejected_factor_f3_per_litre": 0.0, "raw": ["018959", "020094", "0", "2022/Jan/24 12:26", "Viessmann Ltd", "Viessmann", "VITODENS 111-W", "B1LF-32", "", "2021", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "29.3", "29.3", "A", "", "88.5", "88.2", "", "61.8", "", "2", "", "", "106", "1", "2", "21", "3.8", "2", "2", "0", "46", "0", "", "2", "", "", "2", "8.521", "0.193", "0.0004", "2.34902", "14.421", "0.237", "0.0003", "2.32744", "0.0", "", "", "", "00020005", "", "A", "80", "XL", "94", "16", "70", "76.3", "87.9", "98.2", "", "", "", "", "96.3"]} +{"pcdb_id": 18960, "brand_name": "Viessmann", "model_name": "VITODENS 111-W", "model_qualifier": "B1LF-32", "winter_efficiency_pct": 89.8, "summer_efficiency_pct": 85.2, "comparative_hot_water_efficiency_pct": 61.6, "output_kw_max": 29.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 2, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.0006, "loss_factor_f1_kwh_per_day": 2.56778, "loss_factor_f2_kwh_per_day": 2.08007, "rejected_factor_f3_per_litre": 0.0, "raw": ["018960", "020094", "0", "2022/Jan/24 12:26", "Viessmann Ltd", "Viessmann", "VITODENS 111-W", "B1LF-32", "", "2021", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "29.3", "29.3", "A", "", "89.8", "85.2", "", "61.6", "", "2", "0", "2", "106", "1", "2", "21", "3.8", "2", "2", "0", "46", "0", "", "2", "", "", "2", "8.744", "0.184", "0.0006", "2.56778", "15.024", "0.221", "0.0004", "2.08007", "0.0", "", "", "", "00020005", "", "A", "80", "XL", "94", "16", "70", "76.3", "90.1", "98.3", "", "", "", "", "96.7"]} +{"pcdb_id": 18961, "brand_name": "SIME", "model_name": "EDEA", "model_qualifier": "25T", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 24.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018961", "020132", "0", "2022/Mar/05 12:54", "FONDERIE SIME SPA", "SIME", "EDEA", "25T", "41-283-64", "2021", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "11.2", "24.5", "A", "", "88.5", "79.5", "", "58.1", "", "2", "", "", "102", "1", "2", "32", "4", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "93", "17", "80", "105.0", "88.4", "98.0", "", "", "", "", "96.2"]} +{"pcdb_id": 18962, "brand_name": "SIME", "model_name": "EDEA", "model_qualifier": "35T", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 34.1, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018962", "020132", "0", "2022/Mar/05 13:05", "FONDERIE SIME SPA", "SIME", "EDEA", "35T", "41-283-65", "2021", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "16.2", "34.1", "A", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "63", "6", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "93", "15", "105", "115.0", "88.3", "97.8", "", "", "", "", "96.0"]} +{"pcdb_id": 18963, "brand_name": "SIME", "model_name": "EDEA", "model_qualifier": "30", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 73.7, "comparative_hot_water_efficiency_pct": 73.5, "output_kw_max": 24.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.0, "loss_factor_f1_kwh_per_day": 1.05422, "loss_factor_f2_kwh_per_day": 0.0, "rejected_factor_f3_per_litre": -2e-05, "raw": ["018963", "020132", "0", "2022/Mar/05 13:56", "FONDERIE SIME SPA", "SIME", "EDEA", "30", "47-283-91", "2021", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "9.4", "24.5", "A", "", "88.5", "73.7", "", "73.5", "", "2", "", "", "104", "1", "2", "43", "4", "0", "", "", "", "0", "", "", "", "", "2", "7.163", "0.147", "0.0", "1.05422", "14.298", "0.17", "0.0021", "0.0", "-0.00002", "0", "", "", "0025", "", "A", "86", "XL", "93", "17", "86", "105.0", "88.3", "97.8", "", "", "", "", "96.0"]} +{"pcdb_id": 18964, "brand_name": "SIME", "model_name": "EDEA", "model_qualifier": "40", "winter_efficiency_pct": 90.1, "summer_efficiency_pct": 86.6, "comparative_hot_water_efficiency_pct": 70.4, "output_kw_max": 34.1, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.004, "loss_factor_f1_kwh_per_day": 1.45839, "loss_factor_f2_kwh_per_day": 1.17283, "rejected_factor_f3_per_litre": 0.0, "raw": ["018964", "020132", "0", "2022/Mar/05 13:20", "FONDERIE SIME SPA", "SIME", "EDEA", "40", "47-283-92", "2021", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "13.6", "34.1", "A", "", "90.1", "86.6", "", "70.4", "", "2", "", "", "104", "1", "2", "63", "6", "0", "", "", "", "0", "", "", "", "", "2", "7.476", "0.168", "0.004", "1.45839", "13.54", "0.18", "0.0035", "1.17283", "0.0", "0", "", "", "0025", "", "A", "86", "XXL", "93", "15", "105", "115.0", "98.0", "108.5", "", "", "", "", "106.5"]} +{"pcdb_id": 18965, "brand_name": "Viessmann", "model_name": "VITODENS 100-W Heat Only", "model_qualifier": "B1GA-11", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 11.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018965", "020094", "0", "2022/Apr/20 17:58", "Viessmann Ltd", "Viessmann", "VITODENS 100-W Heat Only", "B1GA-11", "41-819-52", "2021", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "11.5", "11.5", "A", "", "88.5", "79.5", "", "58.1", "", "2", "", "", "102", "1", "2", "17", "3.9", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "00020005", "", "", "", "", "92", "20", "77", "54.7", "88.2", "98.0", "", "", "", "", "96.1"]} +{"pcdb_id": 18966, "brand_name": "Viessmann", "model_name": "VITODENS 100-W Heat Only", "model_qualifier": "B1GA-16", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 15.06, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018966", "020094", "0", "2022/Apr/21 12:49", "Viessmann Ltd", "Viessmann", "VITODENS 100-W Heat Only", "B1GA-16", "41-819-53", "2021", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "15.06", "15.06", "A", "", "88.3", "79.3", "", "57.9", "", "2", "", "", "102", "1", "2", "17", "3.9", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "00020005", "", "", "", "", "92", "19", "75", "54.7", "88.1", "97.5", "", "", "", "", "95.7"]} +{"pcdb_id": 18967, "brand_name": "Viessmann", "model_name": "VITODENS 100-W Heat Only", "model_qualifier": "B1GA-19", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 17.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018967", "020094", "0", "2022/Apr/21 13:14", "Viessmann Ltd", "Viessmann", "VITODENS 100-W Heat Only", "B1GA-19", "41-819-54", "2021", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "17.3", "17.3", "A", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "15", "3.9", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "00020005", "", "", "", "", "92", "18", "71", "54.7", "88.0", "97.8", "", "", "", "", "95.9"]} +{"pcdb_id": 18968, "brand_name": "Viessmann", "model_name": "VITODENS 100-W Heat Only", "model_qualifier": "B1GA-25", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 23.06, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018968", "020094", "0", "2022/Apr/21 13:23", "Viessmann Ltd", "Viessmann", "VITODENS 100-W Heat Only", "B1GA-25", "41-819-55", "2021", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "23.06", "23.06", "A", "", "88.5", "79.5", "", "58.0", "", "2", "", "", "102", "1", "2", "15", "3.9", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "00020005", "", "", "", "", "92", "21", "78", "54.7", "87.9", "98.0", "", "", "", "", "96.1"]} +{"pcdb_id": 18969, "brand_name": "Viessmann", "model_name": "VITODENS 100-W Heat Only", "model_qualifier": "B1GA-32", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 29.61, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018969", "020094", "0", "2022/Apr/21 13:29", "Viessmann Ltd", "Viessmann", "VITODENS 100-W Heat Only", "B1GA-32", "41-819-56", "2021", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "29.61", "29.61", "A", "", "88.5", "79.5", "", "58.1", "", "2", "", "", "102", "1", "2", "18", "3.9", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "00020005", "", "", "", "", "93", "26", "90", "54.7", "87.6", "98.2", "", "", "", "", "96.2"]} +{"pcdb_id": 18970, "brand_name": "Bosch", "model_name": "Condens 7000 WP", "model_qualifier": "GC7000WP 50 23", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 47.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018970", "020051", "0", "2022/Jun/21 13:18", "Bosch Thermotechnology Ltd", "Bosch", "Condens 7000 WP", "GC7000WP 50 23", "7736 702 194", "2022", "current", "1", "3", "1", "1", "0", "", "", "2", "2", "2", "47.5", "47.5", "A", "", "88.5", "79.5", "", "58.0", "", "2", "", "", "102", "1", "2", "32", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "8305", "", "", "", "", "93", "10", "52", "115.0", "88.9", "97.6", "", "", "", "", "95.9"]} +{"pcdb_id": 18971, "brand_name": "Bosch", "model_name": "Condens 7000 WP", "model_qualifier": "GC7000WP 65 23", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 64.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018971", "020051", "0", "2022/Jun/21 13:18", "Bosch Thermotechnology Ltd", "Bosch", "Condens 7000 WP", "GC7000WP 65 23", "7736 702 195", "2022", "current", "1", "3", "1", "1", "0", "", "", "2", "3", "2", "64", "64", "A", "", "88.7", "79.7", "", "58.2", "", "2", "", "", "102", "1", "2", "64", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "8305", "", "", "", "", "93", "11", "73", "115.0", "89.1", "98.1", "", "", "", "", "96.4"]} +{"pcdb_id": 18972, "brand_name": "Navien", "model_name": "LCB700", "model_qualifier": "LCB700-28LCX", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 90.0, "comparative_hot_water_efficiency_pct": 45.6, "output_kw_max": 28.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.0055, "loss_factor_f1_kwh_per_day": 5.71125, "loss_factor_f2_kwh_per_day": 5.42319, "rejected_factor_f3_per_litre": 1e-05, "raw": ["018972", "020178", "0", "2022/Oct/21 10:08", "Navien UK", "Navien", "LCB700", "LCB700-28LCX", "28kW Outdoor", "2016", "current", "4", "1", "2", "2", "0", "", "", "2", "2", "2", "28.4", "28.4", "A", "", "89.0", "90.0", "", "45.6", "", "2", "", "", "203", "1", "2", "101", "1.8", "0", "1", "0", "30", "0", "", "0", "", "", "2", "12.007", "0.274", "0.0055", "5.71125", "18.078", "0.31", "0.0045", "5.42319", "0.00001", "", "", "", "0005", "", "B", "73", "XL", "93", "26.8", "128", "84.3", "92.4", "96.6", "", "", "", "", "95.8"]} +{"pcdb_id": 18973, "brand_name": "Sapphire", "model_name": "Sapphire 32KW", "model_qualifier": "", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 81.2, "comparative_hot_water_efficiency_pct": 59.3, "output_kw_max": 32.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018973", "020153", "0", "2022/Jun/27 14:44", "EOGB Energy Products ltd", "Sapphire", "Sapphire 32KW", "", "", "2021", "current", "4", "1", "1", "1", "0", "", "", "2", "2", "2", "32", "32", "A", "", "89.0", "81.2", "", "59.3", "", "2", "", "", "201", "1", "2", "146", "6", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "4015", "", "", "", "", "93", "31", "188", "49.0", "91.6", "97.1", "", "", "", "", "96.0"]} +{"pcdb_id": 18974, "brand_name": "Viessmann", "model_name": "VITODENS 100-W Heat Only", "model_qualifier": "B1GA-11", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 10.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018974", "020094", "0", "2022/Jun/24 10:00", "Viessmann Ltd", "Viessmann", "VITODENS 100-W Heat Only", "B1GA-11", "", "2022", "current", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "10.3", "10.3", "A", "", "89.0", "80.0", "", "58.4", "", "2", "0", "2", "102", "1", "2", "17", "3.9", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "00020005", "", "", "", "", "92", "20", "77", "54.7", "89.2", "96.7", "", "", "", "", "95.3"]} +{"pcdb_id": 18975, "brand_name": "Viessmann", "model_name": "VITODENS 100-W Heat Only", "model_qualifier": "B1GA-19", "winter_efficiency_pct": 89.6, "summer_efficiency_pct": 80.6, "comparative_hot_water_efficiency_pct": 58.9, "output_kw_max": 17.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018975", "020094", "0", "2022/Jun/24 09:54", "Viessmann Ltd", "Viessmann", "VITODENS 100-W Heat Only", "B1GA-19", "", "2022", "current", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "17.2", "17.2", "A", "", "89.6", "80.6", "", "58.9", "", "2", "0", "2", "102", "1", "2", "15", "3.9", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "00020005", "", "", "", "", "92", "18", "71", "54.7", "90.1", "97.9", "", "", "", "", "96.4"]} +{"pcdb_id": 18976, "brand_name": "Viessmann", "model_name": "VITODENS 100-W Heat Only", "model_qualifier": "B1GA-25", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 80.4, "comparative_hot_water_efficiency_pct": 58.8, "output_kw_max": 22.8, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018976", "020094", "0", "2022/Jun/24 09:41", "Viessmann Ltd", "Viessmann", "VITODENS 100-W Heat Only", "B1GA-25", "", "2022", "current", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "22.8", "22.8", "A", "", "89.4", "80.4", "", "58.8", "", "2", "0", "2", "102", "1", "2", "15", "3.9", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "00020005", "", "", "", "", "92", "21", "78", "54.7", "89.7", "97.6", "", "", "", "", "96.1"]} +{"pcdb_id": 18977, "brand_name": "Viessmann", "model_name": "VITODENS 100-W Heat Only", "model_qualifier": "B1GA-32", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 80.4, "comparative_hot_water_efficiency_pct": 58.7, "output_kw_max": 29.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018977", "020094", "0", "2022/Jun/24 09:32", "Viessmann Ltd", "Viessmann", "VITODENS 100-W Heat Only", "B1GA-32", "", "2022", "current", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "29", "29", "A", "", "89.4", "80.4", "", "58.7", "", "2", "0", "2", "102", "1", "2", "18", "3.9", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "00020005", "", "", "", "", "93", "26", "90", "54.7", "89.5", "97.6", "", "", "", "", "96.1"]} +{"pcdb_id": 18978, "brand_name": "Viessmann", "model_name": "VITODENS 100-W Heat Only", "model_qualifier": "B1GA-16", "winter_efficiency_pct": 89.5, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 58.8, "output_kw_max": 14.8, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018978", "020094", "0", "2022/Jun/24 09:23", "Viessmann Ltd", "Viessmann", "VITODENS 100-W Heat Only", "B1GA-16", "", "2022", "current", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "14.8", "14.8", "A", "", "89.5", "80.5", "", "58.8", "", "2", "0", "2", "102", "1", "2", "17", "3.9", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "00020005", "", "", "", "", "92", "19", "75", "54.7", "90.0", "97.6", "", "", "", "", "96.2"]} +{"pcdb_id": 18979, "brand_name": "Viessmann", "model_name": "VITODENS 050-W", "model_qualifier": "B0HA-19", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 17.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018979", "020094", "0", "2022/Jun/24 17:25", "Viessmann Ltd", "Viessmann", "VITODENS 050-W", "B0HA-19", "", "2021", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "17.3", "17.3", "A", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "15", "3.9", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "00020005", "", "", "", "", "92", "18", "71", "54.7", "88.0", "97.8", "", "", "", "", "95.9"]} +{"pcdb_id": 18980, "brand_name": "Viessmann", "model_name": "VITODENS 050-W", "model_qualifier": "B0HA-19", "winter_efficiency_pct": 85.1, "summer_efficiency_pct": 76.1, "comparative_hot_water_efficiency_pct": 55.6, "output_kw_max": 17.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018980", "020094", "0", "2022/Jun/24 17:30", "Viessmann Ltd", "Viessmann", "VITODENS 050-W", "B0HA-19", "", "2022", "current", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "17.2", "17.2", "A", "", "85.1", "76.1", "", "55.6", "", "2", "0", "2", "102", "1", "2", "15", "3.9", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "00020005", "", "", "", "", "92", "18", "71", "54.7", "80.1", "97.2", "", "", "", "", "94.0"]} +{"pcdb_id": 18981, "brand_name": "Viessmann", "model_name": "VITODENS 050-W", "model_qualifier": "B0HA-25", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 80.4, "comparative_hot_water_efficiency_pct": 58.8, "output_kw_max": 22.8, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018981", "020094", "0", "2022/Jun/24 17:30", "Viessmann Ltd", "Viessmann", "VITODENS 050-W", "B0HA-25", "", "2022", "current", "2", "2", "1", "1", "0", "", "", "2", "3", "2", "22.8", "22.8", "A", "", "89.4", "80.4", "", "58.8", "", "2", "0", "2", "102", "1", "2", "15", "3.9", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "00020005", "", "", "", "", "92", "21", "78", "54.7", "89.7", "97.6", "", "", "", "", "96.1"]} +{"pcdb_id": 18982, "brand_name": "Navien", "model_name": "LCB700", "model_qualifier": "LCB700-28LSX", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 81.2, "comparative_hot_water_efficiency_pct": 59.3, "output_kw_max": 28.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018982", "020178", "0", "2022/Oct/21 10:06", "Navien UK", "Navien", "LCB700", "LCB700-28LSX", "LCB700-28kW", "2016", "current", "4", "1", "2", "1", "0", "", "", "2", "2", "2", "28.4", "28.4", "A", "", "89.0", "81.2", "", "59.3", "", "2", "", "", "201", "1", "2", "101", "1.8", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "93", "26.8", "128", "84.3", "92.4", "96.6", "", "", "", "", "95.8"]} +{"pcdb_id": 18983, "brand_name": "Navien", "model_name": "LCB700", "model_qualifier": "LCB700-28RSX", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 81.2, "comparative_hot_water_efficiency_pct": 59.3, "output_kw_max": 28.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018983", "020178", "0", "2022/Oct/21 10:05", "Navien UK", "Navien", "LCB700", "LCB700-28RSX", "", "2016", "current", "4", "1", "2", "1", "0", "", "", "2", "2", "2", "28.4", "28.4", "A", "", "89.0", "81.2", "", "59.3", "", "2", "", "", "201", "1", "2", "101", "1.8", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "93", "26.8", "128", "84.3", "92.4", "96.6", "", "", "", "", "95.8"]} +{"pcdb_id": 18984, "brand_name": "Navien", "model_name": "LCB700", "model_qualifier": "LCB700-36LSX", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 81.3, "comparative_hot_water_efficiency_pct": 59.4, "output_kw_max": 36.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018984", "020178", "0", "2022/Oct/21 10:05", "Navien UK", "Navien", "LCB700", "LCB700-36LSX", "", "2016", "current", "4", "1", "2", "1", "0", "", "", "2", "2", "2", "36.3", "36.3", "A", "", "89.1", "81.3", "", "59.4", "", "2", "", "", "201", "1", "2", "124", "1.7", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "93", "32.8", "153", "73.0", "92.2", "97.1", "", "", "", "", "96.1"]} +{"pcdb_id": 18985, "brand_name": "Navien", "model_name": "LCB700", "model_qualifier": "LCB700-36RSX", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 81.3, "comparative_hot_water_efficiency_pct": 59.4, "output_kw_max": 36.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018985", "020178", "0", "2022/Oct/21 10:04", "Navien UK", "Navien", "LCB700", "LCB700-36RSX", "", "2016", "current", "4", "1", "2", "1", "0", "", "", "2", "2", "2", "36.5", "36.5", "A", "", "89.1", "81.3", "", "59.4", "", "2", "", "", "201", "1", "2", "124", "1.7", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "93", "32.8", "153", "73.0", "92.2", "97.1", "", "", "", "", "96.1"]} +{"pcdb_id": 18986, "brand_name": "Navien", "model_name": "LCB700", "model_qualifier": "LCB700-36LCX", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 91.5, "comparative_hot_water_efficiency_pct": 44.1, "output_kw_max": 36.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.0015, "loss_factor_f1_kwh_per_day": 6.13765, "loss_factor_f2_kwh_per_day": 6.04449, "rejected_factor_f3_per_litre": 0.0, "raw": ["018986", "020178", "0", "2022/Oct/21 10:04", "Navien", "Navien", "LCB700", "LCB700-36LCX", "", "2016", "current", "4", "1", "2", "2", "0", "", "", "2", "2", "2", "36", "36", "A", "", "89.1", "91.5", "", "44.1", "", "2", "", "", "203", "1", "2", "124", "1.7", "0", "", "0", "30", "0", "", "0", "", "", "2", "12.433", "0.3", "0.0015", "6.13765", "18.129", "0.315", "0.0015", "6.04449", "0.0", "", "", "", "0005", "", "B", "73", "XL", "93", "32.8", "153", "73.0", "92.2", "97.1", "", "", "", "", "96.1"]} +{"pcdb_id": 18987, "brand_name": "Navien", "model_name": "LCB700", "model_qualifier": "LCB700-21RSX", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 81.3, "comparative_hot_water_efficiency_pct": 59.4, "output_kw_max": 21.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018987", "020178", "0", "2022/Oct/21 10:04", "Navien UK", "Navien", "LCB700", "LCB700-21RSX", "", "2016", "current", "4", "1", "2", "1", "0", "", "", "2", "2", "2", "21.2", "21.2", "A", "", "89.1", "81.3", "", "59.4", "", "2", "", "", "201", "1", "2", "94", "1.6", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "93", "28", "125", "73.0", "92.0", "97.0", "", "", "", "", "96.0"]} +{"pcdb_id": 18988, "brand_name": "Navien", "model_name": "LCB700", "model_qualifier": "LCB700-21LSX", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 81.3, "comparative_hot_water_efficiency_pct": 59.4, "output_kw_max": 21.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018988", "020178", "0", "2022/Oct/21 10:03", "Navien UK", "Navien", "LCB700", "LCB700-21LSX", "", "2016", "current", "4", "1", "2", "1", "0", "", "", "2", "2", "2", "21.2", "21.2", "A", "", "89.1", "81.3", "", "59.4", "", "2", "", "", "201", "1", "2", "94", "1.6", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "93", "28", "125", "73.1", "92.0", "97.0", "", "", "", "", "96.0"]} +{"pcdb_id": 18989, "brand_name": "Navien", "model_name": "LCB700", "model_qualifier": "LCB700-21LCX", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 91.5, "comparative_hot_water_efficiency_pct": 46.6, "output_kw_max": 21.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.0, "loss_factor_f1_kwh_per_day": 5.47517, "loss_factor_f2_kwh_per_day": 5.39485, "rejected_factor_f3_per_litre": -4e-05, "raw": ["018989", "020178", "0", "2022/Oct/21 10:12", "Navien UK", "Navien", "LCB700", "LCB700-21LCX", "", "2016", "current", "4", "1", "2", "2", "0", "", "", "2", "2", "2", "21.2", "21.2", "A", "", "89.1", "91.5", "", "46.6", "", "2", "", "", "203", "1", "2", "94", "1.6", "0", "", "0", "30", "0", "", "0", "", "", "2", "11.745", "0.284", "0.0", "5.47517", "17.691", "0.3", "0.0035", "5.39485", "-0.00004", "", "", "", "0005", "", "A", "74", "XL", "93", "28", "125", "73.0", "92.0", "97.0", "", "", "", "", "96.0"]} +{"pcdb_id": 18990, "brand_name": "Navien", "model_name": "LCB700", "model_qualifier": "LCB700-36LC", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 91.5, "comparative_hot_water_efficiency_pct": 44.1, "output_kw_max": 36.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.0015, "loss_factor_f1_kwh_per_day": 6.12139, "loss_factor_f2_kwh_per_day": 6.04449, "rejected_factor_f3_per_litre": 0.0, "raw": ["018990", "020178", "0", "2022/Oct/21 10:11", "Navien UK", "Navien", "LCB700", "LCB700-36LC", "", "2016", "current", "4", "1", "1", "2", "0", "", "", "2", "2", "2", "36.3", "36.3", "A", "", "89.1", "91.5", "", "44.1", "", "2", "", "", "203", "1", "2", "124", "1.7", "0", "", "0", "30", "0", "", "0", "", "", "2", "12.433", "0.3", "0.0015", "6.12139", "18.129", "0.315", "0.0015", "6.04449", "0.0", "", "", "", "0005", "", "B", "73", "XL", "93", "32.8", "153", "73.1", "91.8", "97.1", "", "", "", "", "96.1"]} +{"pcdb_id": 18991, "brand_name": "Navien", "model_name": "LCB700", "model_qualifier": "LCB700-36LS", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 81.3, "comparative_hot_water_efficiency_pct": 59.4, "output_kw_max": 36.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018991", "020178", "0", "2022/Oct/21 10:11", "Navien UK", "Navien", "LCB700", "LCB700-36LS", "", "2016", "current", "4", "1", "1", "1", "0", "", "", "2", "2", "2", "36.3", "36.3", "A", "", "89.1", "81.3", "", "59.4", "", "2", "", "", "201", "1", "2", "124", "1.7", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "93", "32.8", "153", "73.1", "91.8", "97.1", "", "", "", "", "96.1"]} +{"pcdb_id": 18992, "brand_name": "Navien", "model_name": "LCB700", "model_qualifier": "LCB700-36RS", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 81.3, "comparative_hot_water_efficiency_pct": 59.4, "output_kw_max": 36.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018992", "020178", "0", "2022/Oct/21 10:11", "Navien UK", "Navien", "LCB700", "LCB700-36RS", "", "2016", "current", "4", "1", "1", "1", "0", "", "", "2", "2", "2", "36.3", "36.3", "A", "", "89.1", "81.3", "", "59.4", "", "2", "", "", "201", "1", "2", "124", "1.7", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "93", "32.8", "153", "73.1", "91.8", "97.1", "", "", "", "", "96.1"]} +{"pcdb_id": 18993, "brand_name": "Navien", "model_name": "LCB700", "model_qualifier": "LCB700-28LC", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 90.0, "comparative_hot_water_efficiency_pct": 45.6, "output_kw_max": 28.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.0055, "loss_factor_f1_kwh_per_day": 5.71125, "loss_factor_f2_kwh_per_day": 5.42319, "rejected_factor_f3_per_litre": 1e-05, "raw": ["018993", "020178", "0", "2022/Oct/21 10:10", "Navien UK", "Navien", "LCB700", "LCB700-28LC", "", "2016", "current", "4", "1", "1", "2", "0", "", "", "2", "2", "2", "28.4", "28.4", "A", "", "89.0", "90.0", "", "45.6", "", "2", "", "", "203", "1", "2", "101", "1.8", "0", "", "0", "30", "0", "", "0", "", "", "2", "12.007", "0.274", "0.0055", "5.71125", "18.078", "0.31", "0.0045", "5.42319", "0.00001", "", "", "", "0005", "", "B", "73", "XL", "93", "27", "128", "84.0", "92.4", "96.6", "", "", "", "", "95.8"]} +{"pcdb_id": 18994, "brand_name": "Navien", "model_name": "LCB700", "model_qualifier": "LCB700-28LS", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 81.2, "comparative_hot_water_efficiency_pct": 59.3, "output_kw_max": 28.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018994", "020178", "0", "2022/Oct/21 10:10", "Navien UK", "Navien", "LCB700", "LCB700-28LS", "", "2016", "current", "4", "1", "1", "1", "0", "", "", "2", "2", "2", "28.4", "28.4", "A", "", "89.0", "81.2", "", "59.3", "", "2", "", "", "201", "1", "2", "101", "1.8", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "93", "27", "128", "84.0", "92.4", "96.6", "", "", "", "", "95.8"]} +{"pcdb_id": 18995, "brand_name": "Navien", "model_name": "LCB700", "model_qualifier": "LCB700-28RS", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 81.2, "comparative_hot_water_efficiency_pct": 59.3, "output_kw_max": 28.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018995", "020178", "0", "2022/Oct/21 10:09", "Navien UK", "Navien", "LCB700", "LCB700-28RS", "", "2016", "current", "4", "1", "1", "1", "0", "", "", "2", "2", "2", "28.4", "28.4", "A", "", "89.0", "81.2", "", "59.3", "", "2", "", "", "201", "1", "2", "101", "1.8", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "93", "27", "128", "84.3", "92.4", "96.6", "", "", "", "", "95.8"]} +{"pcdb_id": 18996, "brand_name": "Navien", "model_name": "LCB700", "model_qualifier": "LCB700-21RS", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 81.3, "comparative_hot_water_efficiency_pct": 59.4, "output_kw_max": 21.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018996", "020178", "0", "2022/Oct/21 10:09", "Navien UK", "Navien", "LCB700", "LCB700-21RS", "", "2016", "current", "4", "1", "1", "1", "0", "", "", "2", "2", "2", "21.2", "21.2", "A", "", "89.1", "81.3", "", "59.4", "", "2", "", "", "201", "1", "2", "94", "1.6", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "93", "28", "125", "73.0", "92.0", "97.0", "", "", "", "", "96.0"]} +{"pcdb_id": 18997, "brand_name": "Navien", "model_name": "LCB700", "model_qualifier": "LCB700-21LS", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 81.3, "comparative_hot_water_efficiency_pct": 59.4, "output_kw_max": 21.62, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018997", "020178", "0", "2022/Oct/21 10:01", "Navien UK", "Navien", "LCB700", "LCB700-21LS", "", "2016", "current", "4", "1", "1", "1", "0", "", "", "2", "2", "2", "21.62", "21.62", "A", "", "89.1", "81.3", "", "59.4", "", "2", "", "", "201", "1", "2", "94", "1.6", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "B", "74", "", "93", "28", "125", "73.0", "92.0", "97.0", "", "", "", "", "96.0"]} +{"pcdb_id": 18998, "brand_name": "Navien", "model_name": "LCB700", "model_qualifier": "LCB700-21LC", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 91.5, "comparative_hot_water_efficiency_pct": 46.6, "output_kw_max": 21.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.0, "loss_factor_f1_kwh_per_day": 5.47517, "loss_factor_f2_kwh_per_day": 5.39485, "rejected_factor_f3_per_litre": -4e-05, "raw": ["018998", "020178", "0", "2022/Oct/21 10:00", "Navien UK", "Navien", "LCB700", "LCB700-21LC", "", "2016", "current", "4", "1", "1", "2", "0", "", "", "2", "2", "2", "21.2", "21.2", "A", "", "89.1", "91.5", "", "46.6", "", "2", "", "", "203", "1", "2", "94", "1.6", "0", "", "0", "30", "0", "", "0", "", "", "2", "11.745", "0.284", "0.0", "5.47517", "17.691", "0.3", "0.0035", "5.39485", "-0.00004", "", "", "", "0005", "", "B", "74", "XL", "93", "28", "125", "73.0", "92.0", "97.0", "", "", "", "", "96.0"]} +{"pcdb_id": 18999, "brand_name": "Viessmann", "model_name": "VITODENS 050-W", "model_qualifier": "B0KA-25", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 86.9, "comparative_hot_water_efficiency_pct": 70.7, "output_kw_max": 17.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.0028, "loss_factor_f1_kwh_per_day": 1.30719, "loss_factor_f2_kwh_per_day": 1.18349, "rejected_factor_f3_per_litre": 1e-05, "raw": ["018999", "020094", "0", "2022/Jul/04 09:57", "Viessmann Ltd", "Viessmann", "VITODENS 050-W", "B0KA-25", "", "2021", "current", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "17.3", "17.3", "A", "", "88.4", "86.9", "", "70.7", "", "2", "", "", "104", "1", "2", "15", "3.9", "0", "", "", "", "0", "", "", "", "", "2", "7.451", "0.17", "0.0028", "1.30719", "13.473", "0.194", "0.0014", "1.18349", "0.00001", "0", "", "", "00020005", "", "A", "82", "XL", "92", "18", "71", "54.7", "88.0", "97.8", "", "", "", "", "95.9"]} +{"pcdb_id": 19000, "brand_name": "Viessmann", "model_name": "VITODENS 050-W", "model_qualifier": "B0KA-30", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 86.6, "comparative_hot_water_efficiency_pct": 71.7, "output_kw_max": 23.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.0025, "loss_factor_f1_kwh_per_day": 1.2094, "loss_factor_f2_kwh_per_day": 1.06, "rejected_factor_f3_per_litre": 2e-05, "raw": ["019000", "020094", "0", "2022/Jul/04 10:15", "Viessmann Ltd", "Viessmann", "VITODENS 050-W", "B0KA-30", "", "2021", "current", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "23", "23", "A", "", "88.5", "86.6", "", "71.7", "", "2", "", "", "104", "1", "2", "15", "3.9", "0", "", "", "", "0", "", "", "", "", "2", "7.35", "0.173", "0.0025", "1.2094", "13.393", "0.194", "0.0008", "1.06", "0.00002", "0", "", "", "00020005", "", "A", "82", "XL", "92", "21", "78", "54.7", "87.9", "98.0", "", "", "", "", "96.1"]} +{"pcdb_id": 19001, "brand_name": "Viessmann", "model_name": "VITODENS 050-W", "model_qualifier": "B0KA-30-M", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 86.6, "comparative_hot_water_efficiency_pct": 71.7, "output_kw_max": 23.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.0025, "loss_factor_f1_kwh_per_day": 1.2094, "loss_factor_f2_kwh_per_day": 1.06, "rejected_factor_f3_per_litre": 2e-05, "raw": ["019001", "020094", "0", "2022/Jul/04 10:31", "Viessmann Ltd", "Viessmann", "VITODENS 050-W", "B0KA-30-M", "", "2021", "current", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "23.6", "23.6", "A", "", "88.5", "86.6", "", "71.7", "", "2", "", "", "104", "1", "2", "13", "3.9", "0", "", "", "", "0", "", "", "", "", "2", "7.35", "0.173", "0.0025", "1.2094", "13.393", "0.194", "0.0008", "1.06", "0.00002", "0", "", "", "00020005", "", "A", "82", "XL", "92", "22", "79", "54.7", "87.9", "98.0", "", "", "", "", "96.1"]} +{"pcdb_id": 19002, "brand_name": "Viessmann", "model_name": "VITODENS 050-W", "model_qualifier": "B0KA-30", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 88.9, "comparative_hot_water_efficiency_pct": 70.1, "output_kw_max": 22.8, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.003, "loss_factor_f1_kwh_per_day": 1.51559, "loss_factor_f2_kwh_per_day": 1.39581, "rejected_factor_f3_per_litre": 1e-05, "raw": ["019002", "020094", "0", "2022/Jul/26 12:00", "Viessmann Ltd", "Viessmann", "VITODENS 050-W", "B0KA-30", "", "2022", "current", "2", "2", "1", "2", "0", "", "", "2", "3", "2", "22.8", "22.8", "A", "", "89.4", "88.9", "", "70.1", "", "2", "0", "2", "104", "1", "2", "15", "3.9", "0", "", "", "", "0", "", "", "", "", "2", "7.676", "0.18", "0.003", "1.51559", "13.701", "0.202", "0.0018", "1.39581", "0.00001", "0", "", "", "00020005", "", "A", "82", "XL", "92", "21", "78", "54.7", "89.7", "97.6", "", "", "", "", "96.1"]} +{"pcdb_id": 19003, "brand_name": "Ideal Heating", "model_name": "LOGIC CODE COMBI2", "model_qualifier": "38", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 98.9, "comparative_hot_water_efficiency_pct": 83.1, "output_kw_max": 24.2, "final_year_of_manufacture": null, "subsidiary_type": 1, "store_type": 0, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.0028, "loss_factor_f1_kwh_per_day": 0.27965, "loss_factor_f2_kwh_per_day": 0.95324, "rejected_factor_f3_per_litre": -1e-05, "raw": ["019003", "020099", "0", "2022/Jul/07 14:14", "Ideal Boilers", "Ideal Heating", "LOGIC CODE COMBI2", "38", "47-387-20", "2022", "current", "1", "2", "1", "2", "1", "", "", "2", "2", "2", "24.2", "24.2", "A", "", "89.0", "98.9", "", "83.1", "", "2", "", "", "104", "1", "2", "79", "2.4", "0", "", "", "", "0", "", "", "", "", "2", "6.335", "0.074", "0.0028", "0.27965", "11.439", "0.096", "0.0035", "0.95324", "-0.00001", "0", "", "", "0035", "", "A", "92", "L", "97", "55", "180", "5.0", "90.0", "98.6", "", "", "", "", "96.9"]} +{"pcdb_id": 19004, "brand_name": "Viessmann", "model_name": "VITODENS 050-W", "model_qualifier": "B0KA-25", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 90.2, "comparative_hot_water_efficiency_pct": 70.2, "output_kw_max": 22.8, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.0054, "loss_factor_f1_kwh_per_day": 1.49868, "loss_factor_f2_kwh_per_day": 1.48907, "rejected_factor_f3_per_litre": 4e-05, "raw": ["019004", "020094", "0", "2022/Jul/26 11:58", "Viessmann Ltd", "Viessmann", "VITODENS 050-W", "B0KA-25", "", "2022", "current", "2", "2", "1", "2", "0", "", "", "2", "3", "2", "22.8", "22.8", "A", "", "89.4", "90.2", "", "70.2", "", "2", "0", "2", "104", "1", "2", "15", "3.9", "0", "", "", "", "0", "", "", "", "", "2", "7.673", "0.178", "0.0054", "1.49868", "13.593", "0.198", "0.0018", "1.48907", "0.00004", "0", "", "", "00020005", "", "A", "82", "XL", "92", "18", "71", "54.7", "89.7", "97.6", "", "", "", "", "96.1"]} +{"pcdb_id": 19005, "brand_name": "Viessmann", "model_name": "VITODENS 050-W", "model_qualifier": "B0HA-25", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 23.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["019005", "020094", "0", "2022/Jun/24 17:25", "Viessmann Ltd", "Viessmann", "VITODENS 050-W", "B0HA-25", "", "2021", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "23", "23", "A", "", "88.5", "79.5", "", "58.0", "", "2", "", "", "102", "1", "2", "15", "3.9", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "00020005", "", "", "", "", "92", "21", "78", "54.7", "87.9", "98.0", "", "", "", "", "96.1"]} +{"pcdb_id": 19006, "brand_name": "Ideal Heating", "model_name": "LOGIC COMBI2", "model_qualifier": "C24", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 88.2, "comparative_hot_water_efficiency_pct": 70.0, "output_kw_max": 24.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.0115, "loss_factor_f1_kwh_per_day": 1.37564, "loss_factor_f2_kwh_per_day": 1.30006, "rejected_factor_f3_per_litre": 7e-05, "raw": ["019006", "020099", "0", "2024/Dec/10 16:50", "Ideal Boilers", "Ideal Heating", "LOGIC COMBI2", "C24", "47-349-93", "2022", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "A", "", "89.0", "88.2", "", "70.0", "", "2", "", "", "104", "1", "2", "46", "2", "0", "", "", "", "0", "", "", "", "", "2", "7.518", "0.131", "0.0115", "1.37564", "13.292", "0.157", "0.0045", "1.30006", "0.00007", "0", "", "", "0035", "", "A", "81", "L", "94", "13", "67", "50.0", "90.0", "98.6", "", "", "", "", "96.9"]} +{"pcdb_id": 19007, "brand_name": "Ideal Heating", "model_name": "LOGIC COMBI2", "model_qualifier": "C30", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 88.2, "comparative_hot_water_efficiency_pct": 70.9, "output_kw_max": 24.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.0045, "loss_factor_f1_kwh_per_day": 1.3264, "loss_factor_f2_kwh_per_day": 1.25175, "rejected_factor_f3_per_litre": 2e-05, "raw": ["019007", "020099", "0", "2024/Dec/10 16:51", "Ideal Boilers", "Ideal Heating", "LOGIC COMBI2", "C30", "47-349-94", "2022", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "A", "", "89.0", "88.2", "", "70.9", "", "2", "", "", "104", "1", "2", "27", "3", "0", "", "", "", "0", "", "", "", "", "2", "7.425", "0.137", "0.0045", "1.3264", "13.175", "0.157", "0.003", "1.25175", "0.00002", "0", "", "", "0035", "", "A", "81", "L", "94", "10", "55", "50.0", "90.0", "98.6", "", "", "", "", "96.9"]} +{"pcdb_id": 19008, "brand_name": "Ideal Heating", "model_name": "LOGIC COMBI2", "model_qualifier": "C35", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 86.6, "comparative_hot_water_efficiency_pct": 69.3, "output_kw_max": 24.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.0135, "loss_factor_f1_kwh_per_day": 1.44344, "loss_factor_f2_kwh_per_day": 1.23652, "rejected_factor_f3_per_litre": 8e-05, "raw": ["019008", "020099", "0", "2024/Dec/10 16:52", "Ideal Boilers", "Ideal Heating", "LOGIC COMBI2", "C35", "47-349-95", "2022", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "A", "", "89.0", "86.6", "", "69.3", "", "2", "", "", "104", "1", "2", "26", "2", "0", "", "", "", "0", "", "", "", "", "2", "7.6", "0.136", "0.0135", "1.44344", "13.634", "0.158", "0.006", "1.23652", "0.00008", "0", "", "", "0035", "", "A", "79", "L", "94", "12", "53", "50.0", "90.0", "98.6", "", "", "", "", "96.9"]} +{"pcdb_id": 19009, "brand_name": "Ideal Heating", "model_name": "LOGIC HEAT2", "model_qualifier": "H12", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 12.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["019009", "020099", "0", "2024/Dec/10 17:06", "Ideal Boilers", "Ideal Heating", "LOGIC HEAT2", "H12", "41-860-10", "2022", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "12", "12", "A", "", "88.8", "79.8", "", "58.3", "", "2", "", "", "102", "1", "2", "16", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "93", "11", "45", "50.0", "90.0", "97.9", "", "", "", "", "96.4"]} +{"pcdb_id": 19010, "brand_name": "Ideal Heating", "model_name": "LOGIC HEAT2", "model_qualifier": "H15", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 15.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["019010", "020099", "0", "2024/Dec/10 17:06", "Ideal Boilers", "Ideal Heating", "LOGIC HEAT2", "H15", "41-860-11", "2022", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "15", "15", "A", "", "88.7", "79.7", "", "58.2", "", "2", "", "", "102", "1", "2", "22", "3", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "93", "11", "55", "50.0", "90.0", "97.8", "", "", "", "", "96.4"]} +{"pcdb_id": 19011, "brand_name": "Ideal Heating", "model_name": "LOGIC HEAT2", "model_qualifier": "H18", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 18.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["019011", "020099", "0", "2024/Dec/10 17:07", "Ideal Boilers", "Ideal Heating", "LOGIC HEAT2", "H18", "41-860-12", "2022", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18", "18", "A", "", "89.0", "80.0", "", "58.4", "", "2", "", "", "102", "1", "2", "25", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "93", "4", "35", "50.0", "89.8", "98.5", "", "", "", "", "96.8"]} +{"pcdb_id": 19012, "brand_name": "Ideal Heating", "model_name": "LOGIC HEAT2", "model_qualifier": "H24", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 24.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["019012", "020099", "0", "2024/Dec/10 17:07", "Ideal Boilers", "Ideal Heating", "LOGIC HEAT2", "H24", "41-860-13", "2022", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24.2", "24.2", "A", "", "89.0", "80.0", "", "58.5", "", "2", "", "", "102", "1", "2", "46", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "94", "13", "67", "50.0", "90.0", "98.6", "", "", "", "", "96.9"]} +{"pcdb_id": 19013, "brand_name": "Ideal Heating", "model_name": "LOGIC HEAT2", "model_qualifier": "H30", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 30.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["019013", "020099", "0", "2024/Dec/10 17:08", "Ideal Boilers", "Ideal Heating", "LOGIC HEAT2", "H30", "41-860-14", "2022", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "30.4", "30.4", "A", "", "88.9", "79.9", "", "58.3", "", "2", "", "", "102", "1", "2", "50", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "93", "12", "67", "50.0", "89.8", "98.2", "", "", "", "", "96.6"]} +{"pcdb_id": 19014, "brand_name": "Ideal Heating", "model_name": "LOGIC SYSTEM2", "model_qualifier": "S15", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 15.1, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["019014", "020099", "0", "2024/Dec/11 10:25", "Ideal Boilers", "Ideal Heating", "LOGIC SYSTEM2", "S15", "41-796-85", "2022", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "15.1", "15.1", "A", "", "88.7", "79.7", "", "58.2", "", "2", "", "", "102", "1", "2", "42", "3", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "93", "17", "79", "50.0", "90.0", "97.8", "", "", "", "", "96.4"]} +{"pcdb_id": 19015, "brand_name": "Ideal Heating", "model_name": "LOGIC SYSTEM2", "model_qualifier": "S18", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 18.1, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["019015", "020099", "0", "2024/Dec/11 10:26", "Ideal Boilers", "Ideal Heating", "LOGIC SYSTEM2", "S18", "41-796-86", "2022", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18.1", "18.1", "A", "", "89.0", "80.0", "", "58.4", "", "2", "", "", "102", "1", "2", "25", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "93", "3", "33", "50.0", "89.8", "98.5", "", "", "", "", "96.8"]} +{"pcdb_id": 19016, "brand_name": "Ideal Heating", "model_name": "LOGIC SYSTEM2", "model_qualifier": "S24", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 24.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["019016", "020099", "0", "2024/Dec/11 10:54", "Ideal Boilers", "Ideal Heating", "LOGIC SYSTEM2", "S24", "41-796-87", "2022", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24.3", "24.3", "A", "", "89.0", "80.0", "", "58.5", "", "2", "", "", "102", "1", "2", "46", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "94", "13", "67", "50.0", "90.0", "98.6", "", "", "", "", "96.9"]} +{"pcdb_id": 19017, "brand_name": "Ideal Heating", "model_name": "LOGIC SYSTEM2", "model_qualifier": "S30", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 30.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["019017", "020099", "0", "2024/Dec/11 11:03", "Ideal Boilers", "Ideal Heating", "LOGIC SYSTEM2", "S30", "41-796-88", "2022", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "30.4", "30.4", "A", "", "88.9", "79.9", "", "58.3", "", "2", "", "", "102", "1", "2", "50", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "93", "12", "67", "50.0", "89.8", "98.2", "", "", "", "", "96.6"]} +{"pcdb_id": 19018, "brand_name": "Ideal Heating", "model_name": "LOGIC MAX COMBI2", "model_qualifier": "C24", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 88.2, "comparative_hot_water_efficiency_pct": 69.2, "output_kw_max": 24.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.0065, "loss_factor_f1_kwh_per_day": 1.4989, "loss_factor_f2_kwh_per_day": 1.42234, "rejected_factor_f3_per_litre": 5e-05, "raw": ["019018", "020099", "0", "2024/Dec/11 10:13", "Ideal Boilers", "Ideal Heating", "LOGIC MAX COMBI2", "C24", "47-387-03", "2022", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "A", "", "89.0", "88.2", "", "69.2", "", "2", "", "", "104", "1", "2", "44", "2", "0", "", "", "", "0", "", "", "", "", "2", "7.615", "0.114", "0.0065", "1.4989", "13.2", "0.136", "0.0015", "1.42234", "0.00005", "0", "", "", "0035", "", "A", "82", "L", "94", "13", "66", "50.0", "90.0", "98.6", "", "", "", "", "96.9"]} +{"pcdb_id": 19019, "brand_name": "Ideal Heating", "model_name": "LOGIC MAX COMBI2", "model_qualifier": "C30", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 88.2, "comparative_hot_water_efficiency_pct": 69.7, "output_kw_max": 24.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.0055, "loss_factor_f1_kwh_per_day": 1.44658, "loss_factor_f2_kwh_per_day": 1.37062, "rejected_factor_f3_per_litre": 4e-05, "raw": ["019019", "020099", "0", "2024/Dec/11 10:14", "Ideal Boilers", "Ideal Heating", "LOGIC MAX COMBI2", "C30", "47-387-04", "2022", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "A", "", "89.0", "88.2", "", "69.7", "", "2", "", "", "104", "1", "2", "28", "3", "0", "", "", "", "0", "", "", "", "", "2", "7.555", "0.114", "0.0055", "1.44658", "13.358", "0.133", "0.002", "1.37062", "0.00004", "0", "", "", "0035", "", "A", "81", "L", "94", "9", "54", "50.0", "90.0", "98.6", "", "", "", "", "96.9"]} +{"pcdb_id": 19020, "brand_name": "Ideal Heating", "model_name": "LOGIC MAX COMBI2", "model_qualifier": "C35", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 86.7, "comparative_hot_water_efficiency_pct": 69.4, "output_kw_max": 24.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.005, "loss_factor_f1_kwh_per_day": 1.48634, "loss_factor_f2_kwh_per_day": 1.28345, "rejected_factor_f3_per_litre": 3e-05, "raw": ["019020", "020099", "0", "2024/Dec/11 10:14", "Ideal Boilers", "Ideal Heating", "LOGIC MAX COMBI2", "C35", "47-387-05", "2022", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "A", "", "89.0", "86.7", "", "69.4", "", "2", "", "", "104", "1", "2", "28", "2", "0", "", "", "", "0", "", "", "", "", "2", "7.593", "0.117", "0.005", "1.48634", "13.633", "0.137", "0.0025", "1.28345", "0.00003", "0", "", "", "0035", "", "A", "79", "L", "94", "26", "85", "50.0", "90.0", "98.6", "", "", "", "", "96.9"]} +{"pcdb_id": 19021, "brand_name": "Ideal Heating", "model_name": "LOGIC MAX SYSTEM2", "model_qualifier": "S15", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 15.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["019021", "020099", "0", "2024/Dec/11 10:20", "Ideal Boilers", "Ideal Heating", "LOGIC MAX SYSTEM2", "S15", "41-796-97", "2022", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "15", "15", "A", "", "88.7", "79.7", "", "58.2", "", "2", "", "", "102", "1", "2", "20", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "93", "3", "30", "50.0", "90.0", "97.8", "", "", "", "", "96.4"]} +{"pcdb_id": 19022, "brand_name": "Ideal Heating", "model_name": "LOGIC MAX SYSTEM2", "model_qualifier": "S18", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 18.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["019022", "020099", "0", "2024/Dec/11 10:21", "Ideal Boilers", "Ideal Heating", "LOGIC MAX SYSTEM2", "S18", "41-796-98", "2022", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18", "18", "A", "", "89.0", "80.0", "", "58.4", "", "2", "", "", "102", "1", "2", "25", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "93", "23", "77", "50.0", "89.8", "98.5", "", "", "", "", "96.8"]} +{"pcdb_id": 19023, "brand_name": "Ideal Heating", "model_name": "LOGIC MAX SYSTEM2", "model_qualifier": "S24", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 24.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["019023", "020099", "0", "2024/Dec/11 10:21", "Ideal Boilers", "Ideal Heating", "LOGIC MAX SYSTEM2", "S24", "41-796-99", "2022", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24.2", "24.2", "A", "", "89.0", "80.0", "", "58.5", "", "2", "", "", "102", "1", "2", "44", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "94", "12", "64", "50.0", "90.0", "98.6", "", "", "", "", "96.9"]} +{"pcdb_id": 19024, "brand_name": "Ideal Heating", "model_name": "LOGIC MAX SYSTEM2", "model_qualifier": "S30", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 30.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["019024", "020099", "0", "2024/Dec/11 10:24", "Ideal Boilers", "Ideal Heating", "LOGIC MAX SYSTEM2", "S30", "41-860-01", "2022", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "30", "30", "A", "", "88.9", "79.9", "", "58.3", "", "2", "", "", "102", "1", "2", "52", "1", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "93", "12", "62", "50.0", "89.8", "98.2", "", "", "", "", "96.6"]} +{"pcdb_id": 19025, "brand_name": "Ideal Heating", "model_name": "LOGIC MAX HEAT2", "model_qualifier": "H12", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 12.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["019025", "020099", "0", "2024/Dec/11 10:15", "Ideal Boilers", "Ideal Heating", "LOGIC MAX HEAT2", "H12", "41-860-25", "2022", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "12", "12", "A", "", "88.8", "79.8", "", "58.3", "", "2", "", "", "102", "1", "2", "17", "1", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "93", "12", "42", "50.0", "90.0", "97.9", "", "", "", "", "96.4"]} +{"pcdb_id": 19026, "brand_name": "Ideal Heating", "model_name": "LOGIC MAX HEAT2", "model_qualifier": "H15", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 15.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["019026", "020099", "0", "2024/Dec/11 10:16", "Ideal Boilers", "Ideal Heating", "LOGIC MAX HEAT2", "H15", "41-860-26", "2022", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "15", "15", "A", "", "88.7", "79.7", "", "58.2", "", "2", "", "", "102", "1", "2", "20", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "93", "3", "30", "50.0", "90.0", "97.8", "", "", "", "", "96.4"]} +{"pcdb_id": 19027, "brand_name": "Ideal Heating", "model_name": "LOGIC MAX HEAT2", "model_qualifier": "H24", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 24.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["019027", "020099", "0", "2024/Dec/11 10:18", "Ideal Boilers", "Ideal Heating", "LOGIC MAX HEAT2", "H24", "41-860-28", "2022", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24.2", "24.2", "A", "", "89.0", "80.0", "", "58.5", "", "2", "", "", "102", "1", "2", "44", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "94", "12", "64", "50.0", "90.0", "98.6", "", "", "", "", "96.9"]} +{"pcdb_id": 19028, "brand_name": "Ideal Heating", "model_name": "LOGIC MAX HEAT2", "model_qualifier": "H30", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 30.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["019028", "020099", "0", "2024/Dec/11 10:18", "Ideal Boilers", "Ideal Heating", "LOGIC MAX HEAT2", "H30", "41-860-29", "2022", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "30", "30", "A", "", "88.8", "79.8", "", "58.3", "", "2", "", "", "102", "1", "2", "52", "1", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "93", "12", "62", "50.0", "89.6", "98.2", "", "", "", "", "96.6"]} +{"pcdb_id": 19029, "brand_name": "Ideal Heating", "model_name": "INDEPENDENT COMBI2", "model_qualifier": "C24", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 88.2, "comparative_hot_water_efficiency_pct": 70.0, "output_kw_max": 24.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.0115, "loss_factor_f1_kwh_per_day": 1.37564, "loss_factor_f2_kwh_per_day": 1.30006, "rejected_factor_f3_per_litre": 7e-05, "raw": ["019029", "020099", "0", "2022/Oct/17 17:06", "Ideal Boilers", "Ideal Heating", "INDEPENDENT COMBI2", "C24", "47-387-09", "2022", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "A", "", "89.0", "88.2", "", "70.0", "", "2", "", "", "104", "1", "2", "46", "2", "0", "", "", "", "0", "", "", "", "", "2", "7.518", "0.131", "0.0115", "1.37564", "13.292", "0.157", "0.0045", "1.30006", "0.00007", "0", "", "", "0015", "", "A", "81", "L", "94", "13", "67", "50.0", "90.0", "98.6", "", "", "", "", "96.9"]} +{"pcdb_id": 19030, "brand_name": "Ideal Heating", "model_name": "INDEPENDENT COMBI2", "model_qualifier": "C30", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 88.2, "comparative_hot_water_efficiency_pct": 70.9, "output_kw_max": 24.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.0045, "loss_factor_f1_kwh_per_day": 1.3264, "loss_factor_f2_kwh_per_day": 1.25175, "rejected_factor_f3_per_litre": 2e-05, "raw": ["019030", "020099", "0", "2022/Oct/17 17:10", "Ideal Boilers", "Ideal Heating", "INDEPENDENT COMBI2", "C30", "47-387-10", "2022", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "A", "", "89.0", "88.2", "", "70.9", "", "2", "", "", "104", "1", "2", "27", "3", "0", "", "", "", "0", "", "", "", "", "2", "7.425", "0.137", "0.0045", "1.3264", "13.175", "0.157", "0.003", "1.25175", "0.00002", "0", "", "", "0015", "", "A", "81", "L", "94", "9", "53", "50.0", "90.0", "98.6", "", "", "", "", "96.9"]} +{"pcdb_id": 19031, "brand_name": "Ideal Heating", "model_name": "INDEPENDENT COMBI2", "model_qualifier": "C35", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 86.6, "comparative_hot_water_efficiency_pct": 69.3, "output_kw_max": 24.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.0135, "loss_factor_f1_kwh_per_day": 1.44344, "loss_factor_f2_kwh_per_day": 1.23652, "rejected_factor_f3_per_litre": 8e-05, "raw": ["019031", "020099", "0", "2022/Oct/17 17:18", "Ideal Boilers", "Ideal Heating", "INDEPENDENT COMBI2", "C35", "47-387-11", "2022", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "A", "", "89.0", "86.6", "", "69.3", "", "2", "", "", "104", "1", "2", "26", "2", "0", "", "", "", "0", "", "", "", "", "2", "7.6", "0.136", "0.0135", "1.44344", "13.634", "0.158", "0.006", "1.23652", "0.00008", "0", "", "", "0015", "", "A", "79", "L", "94", "12", "53", "50.0", "90.0", "98.6", "", "", "", "", "96.9"]} +{"pcdb_id": 19032, "brand_name": "Ideal Heating", "model_name": "INDEPENDENT SYSTEM2", "model_qualifier": "S15", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 15.1, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["019032", "020099", "0", "2022/Oct/18 15:14", "Ideal Boilers", "Ideal Heating", "INDEPENDENT SYSTEM2", "S15", "41-860-06", "2022", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "15.1", "15.1", "A", "", "88.7", "79.7", "", "58.2", "", "2", "", "", "102", "1", "2", "22", "3", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0015", "", "", "", "", "93", "11", "55", "50.0", "90.0", "97.8", "", "", "", "", "96.4"]} +{"pcdb_id": 19033, "brand_name": "Ideal Heating", "model_name": "INDEPENDENT SYSTEM2", "model_qualifier": "S18", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 18.1, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["019033", "020099", "0", "2022/Oct/18 15:14", "Ideal Boilers", "Ideal Heating", "INDEPENDENT SYSTEM2", "S18", "41-860-07", "2022", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18.1", "18.1", "A", "", "89.0", "80.0", "", "58.4", "", "2", "", "", "102", "1", "2", "25", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0015", "", "", "", "", "94", "3", "33", "50.0", "89.8", "98.5", "", "", "", "", "96.8"]} +{"pcdb_id": 19034, "brand_name": "Ideal Heating", "model_name": "INDEPENDENT SYSTEM2", "model_qualifier": "S24", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 24.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["019034", "020099", "0", "2022/Oct/18 15:14", "Ideal Boilers", "Ideal Heating", "INDEPENDENT SYSTEM2", "S24", "41-860-08", "2022", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24.2", "24.2", "A", "", "89.0", "80.0", "", "58.5", "", "2", "", "", "102", "1", "2", "46", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0015", "", "", "", "", "94", "13", "67", "50.0", "90.0", "98.6", "", "", "", "", "96.9"]} +{"pcdb_id": 19035, "brand_name": "Ideal Heating", "model_name": "INDEPENDENT SYSTEM2", "model_qualifier": "S30", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 30.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["019035", "020099", "0", "2022/Oct/18 15:15", "Ideal Boilers", "Ideal Heating", "INDEPENDENT SYSTEM2", "S30", "41-860-09", "2022", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "30", "30", "A", "", "88.9", "79.9", "", "58.3", "", "2", "", "", "102", "1", "2", "50", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0015", "", "", "", "", "93", "12", "67", "50.0", "89.8", "98.2", "", "", "", "", "96.6"]} +{"pcdb_id": 19036, "brand_name": "Ideal Heating", "model_name": "LOGIC MAX HEAT2", "model_qualifier": "H18", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 18.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["019036", "020099", "0", "2024/Dec/11 10:17", "Ideal Boilers", "Ideal Heating", "LOGIC MAX HEAT2", "H18", "41-860-27", "2022", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18", "18", "A", "", "89.0", "80.0", "", "58.4", "", "2", "", "", "102", "1", "2", "25", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "93", "23", "77", "50.0", "89.8", "98.5", "", "", "", "", "96.8"]} +{"pcdb_id": 19037, "brand_name": "Ideal Heating", "model_name": "LOGIC+ COMBI2", "model_qualifier": "C24", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 88.2, "comparative_hot_water_efficiency_pct": 69.2, "output_kw_max": 24.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.0065, "loss_factor_f1_kwh_per_day": 1.4989, "loss_factor_f2_kwh_per_day": 1.42234, "rejected_factor_f3_per_litre": 5e-05, "raw": ["019037", "020099", "0", "2024/Dec/11 11:06", "Ideal Boilers", "Ideal Heating", "LOGIC+ COMBI2", "C24", "47-349-99", "2022", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "A", "", "89.0", "88.2", "", "69.2", "", "2", "", "", "104", "1", "2", "44", "2", "0", "", "", "", "0", "", "", "", "", "2", "7.615", "0.114", "0.0065", "1.4989", "13.2", "0.136", "0.0015", "1.42234", "0.00005", "0", "", "", "0035", "", "A", "82", "L", "94", "13", "66", "50.0", "90.0", "98.6", "", "", "", "", "96.9"]} +{"pcdb_id": 19038, "brand_name": "Ideal Heating", "model_name": "LOGIC+ COMBI2", "model_qualifier": "C30", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 88.2, "comparative_hot_water_efficiency_pct": 69.7, "output_kw_max": 24.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.0055, "loss_factor_f1_kwh_per_day": 1.44658, "loss_factor_f2_kwh_per_day": 1.37062, "rejected_factor_f3_per_litre": 4e-05, "raw": ["019038", "020099", "0", "2024/Dec/11 11:06", "Ideal Boilers", "Ideal Heating", "LOGIC+ COMBI2", "C30", "47-387-01", "2022", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "A", "", "89.0", "88.2", "", "69.7", "", "2", "", "", "104", "1", "2", "28", "3", "0", "", "", "", "0", "", "", "", "", "2", "7.555", "0.114", "0.0055", "1.44658", "13.358", "0.133", "0.002", "1.37062", "0.00004", "0", "", "", "0035", "", "A", "81", "L", "94", "9", "54", "50.0", "90.0", "98.6", "", "", "", "", "96.9"]} +{"pcdb_id": 19039, "brand_name": "Ideal Heating", "model_name": "LOGIC+ COMBI2", "model_qualifier": "C35", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 86.7, "comparative_hot_water_efficiency_pct": 69.4, "output_kw_max": 24.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.005, "loss_factor_f1_kwh_per_day": 1.48634, "loss_factor_f2_kwh_per_day": 1.28345, "rejected_factor_f3_per_litre": 3e-05, "raw": ["019039", "020099", "0", "2024/Dec/11 11:07", "Ideal Boilers", "Ideal Heating", "LOGIC+ COMBI2", "C35", "47-387-02", "2022", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "A", "", "89.0", "86.7", "", "69.4", "", "2", "", "", "104", "1", "2", "28", "2", "0", "", "", "", "0", "", "", "", "", "2", "7.593", "0.117", "0.005", "1.48634", "13.633", "0.137", "0.0025", "1.28345", "0.00003", "0", "", "", "0035", "", "A", "79", "L", "94", "26", "85", "50.0", "90.0", "98.6", "", "", "", "", "96.9"]} +{"pcdb_id": 19040, "brand_name": "Ideal Heating", "model_name": "LOGIC+ HEAT2", "model_qualifier": "H12", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 12.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["019040", "020099", "0", "2024/Dec/11 11:12", "Ideal Boilers", "Ideal Heating", "LOGIC+ HEAT2", "H12", "41-860-20", "2022", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "12", "12", "A", "", "88.8", "79.8", "", "58.3", "", "2", "", "", "102", "1", "2", "17", "1", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "93", "12", "42", "50.0", "90.0", "97.9", "", "", "", "", "96.4"]} +{"pcdb_id": 19041, "brand_name": "Ideal Heating", "model_name": "LOGIC+ HEAT2", "model_qualifier": "H15", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 15.1, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["019041", "020099", "0", "2024/Dec/11 11:12", "Ideal Boilers", "Ideal Heating", "LOGIC+ HEAT2", "H15", "41-860-21", "2022", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "15.1", "15.1", "A", "", "88.7", "79.7", "", "58.2", "", "2", "", "", "102", "1", "2", "20", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "93", "3", "30", "50.0", "90.0", "97.8", "", "", "", "", "96.4"]} +{"pcdb_id": 19042, "brand_name": "Ideal Heating", "model_name": "LOGIC+ HEAT2", "model_qualifier": "H18", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 18.1, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["019042", "020099", "0", "2024/Dec/11 11:13", "Ideal Boilers", "Ideal Heating", "LOGIC+ HEAT2", "H18", "41-860-22", "2022", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18.1", "18.1", "A", "", "89.0", "80.0", "", "58.4", "", "2", "", "", "102", "1", "2", "25", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "93", "23", "77", "50.0", "89.8", "98.5", "", "", "", "", "96.8"]} +{"pcdb_id": 19043, "brand_name": "Ideal Heating", "model_name": "LOGIC+ HEAT2", "model_qualifier": "H24", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 24.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["019043", "020099", "0", "2024/Dec/11 11:14", "Ideal Boilers", "Ideal Heating", "LOGIC+ HEAT2", "H24", "41-860-23", "2022", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24.2", "24.2", "A", "", "89.0", "80.0", "", "58.5", "", "2", "", "", "102", "1", "2", "44", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "94", "12", "64", "50.0", "90.0", "98.6", "", "", "", "", "96.9"]} +{"pcdb_id": 19044, "brand_name": "Ideal Heating", "model_name": "LOGIC+ HEAT2", "model_qualifier": "H30", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 30.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["019044", "020099", "0", "2024/Dec/11 11:15", "Ideal Boilers", "Ideal Heating", "LOGIC+ HEAT2", "H30", "41-860-24", "2022", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "30", "30", "A", "", "88.8", "79.8", "", "58.3", "", "2", "", "", "102", "1", "2", "52", "1", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "93", "12", "62", "50.0", "89.6", "98.2", "", "", "", "", "96.6"]} +{"pcdb_id": 19045, "brand_name": "Ideal Heating", "model_name": "LOGIC+ SYSTEM2", "model_qualifier": "S15", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 15.1, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["019045", "020099", "0", "2024/Dec/11 11:15", "Ideal Boilers", "Ideal Heating", "LOGIC+ SYSTEM2", "S15", "41-796-93", "2022", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "15.1", "15.1", "A", "", "88.7", "79.7", "", "58.2", "", "2", "", "", "102", "1", "2", "20", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "93", "3", "30", "50.0", "90.0", "97.8", "", "", "", "", "96.3"]} +{"pcdb_id": 19046, "brand_name": "Ideal Heating", "model_name": "LOGIC+ SYSTEM2", "model_qualifier": "S18", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 18.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["019046", "020099", "0", "2024/Dec/11 11:16", "Ideal Boilers", "Ideal Heating", "LOGIC+ SYSTEM2", "S18", "41-796-94", "2022", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18", "18", "A", "", "89.0", "80.0", "", "58.4", "", "2", "", "", "102", "1", "2", "25", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "94", "23", "77", "50.0", "89.8", "98.5", "", "", "", "", "96.8"]} +{"pcdb_id": 19047, "brand_name": "Ideal Heating", "model_name": "LOGIC+ SYSTEM2", "model_qualifier": "S24", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 24.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["019047", "020099", "0", "2024/Dec/11 11:16", "Ideal Boilers", "Ideal Heating", "LOGIC+ SYSTEM2", "S24", "41-796-95", "2022", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24.2", "24.2", "A", "", "89.0", "80.0", "", "58.5", "", "2", "", "", "102", "1", "2", "44", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "94", "12", "64", "50.0", "90.0", "98.6", "", "", "", "", "96.9"]} +{"pcdb_id": 19048, "brand_name": "Ideal Heating", "model_name": "LOGIC+ SYSTEM2", "model_qualifier": "S30", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 30.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["019048", "020099", "0", "2024/Dec/11 11:17", "Ideal Boilers", "Ideal Heating", "LOGIC+ SYSTEM2", "S30", "41-796-96", "2022", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "30", "30", "A", "", "88.9", "79.9", "", "58.3", "", "2", "", "", "102", "1", "2", "52", "1", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0035", "", "", "", "", "93", "12", "62", "50.0", "89.8", "98.2", "", "", "", "", "96.6"]} +{"pcdb_id": 19049, "brand_name": "i-mini", "model_name": "i-mini2", "model_qualifier": "c24", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 88.2, "comparative_hot_water_efficiency_pct": 70.0, "output_kw_max": 24.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.0115, "loss_factor_f1_kwh_per_day": 1.37564, "loss_factor_f2_kwh_per_day": 1.30006, "rejected_factor_f3_per_litre": 7e-05, "raw": ["019049", "020099", "0", "2022/Oct/20 08:17", "Ideal Boilers", "i-mini", "i-mini2", "c24", "47-387-15", "2022", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "A", "", "89.0", "88.2", "", "70.0", "", "2", "", "", "104", "1", "2", "46", "2", "0", "", "", "", "0", "", "", "", "", "2", "7.518", "0.131", "0.0115", "1.37564", "13.292", "0.157", "0.0045", "1.30006", "0.00007", "0", "", "", "0015", "", "A", "81", "L", "94", "13", "67", "50.0", "90.0", "98.6", "", "", "", "", "96.9"]} +{"pcdb_id": 19050, "brand_name": "i-mini", "model_name": "i-mini2", "model_qualifier": "c30", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 88.2, "comparative_hot_water_efficiency_pct": 70.9, "output_kw_max": 24.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.0045, "loss_factor_f1_kwh_per_day": 1.3264, "loss_factor_f2_kwh_per_day": 1.25175, "rejected_factor_f3_per_litre": 2e-05, "raw": ["019050", "020099", "0", "2022/Oct/19 16:35", "Ideal Boilers", "i-mini", "i-mini2", "c30", "47-387-16", "2022", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "A", "", "89.0", "88.2", "", "70.9", "", "2", "", "", "104", "1", "2", "27", "3", "0", "", "", "", "0", "", "", "", "", "2", "7.425", "0.137", "0.0045", "1.3264", "13.175", "0.157", "0.003", "1.25175", "0.00002", "0", "", "", "0015", "", "A", "81", "L", "94", "10", "55", "50.0", "90.0", "98.6", "", "", "", "", "96.9"]} +{"pcdb_id": 19051, "brand_name": "Keston", "model_name": "KESTON COMBI2", "model_qualifier": "C30", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 88.2, "comparative_hot_water_efficiency_pct": 69.7, "output_kw_max": 24.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.0055, "loss_factor_f1_kwh_per_day": 1.44658, "loss_factor_f2_kwh_per_day": 1.37062, "rejected_factor_f3_per_litre": 4e-05, "raw": ["019051", "020099", "0", "2022/Oct/19 16:27", "Ideal Boilers", "Keston", "KESTON COMBI2", "C30", "47-830-09", "2022", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "A", "", "89.0", "88.2", "", "69.7", "", "2", "", "", "104", "1", "2", "28", "3", "0", "", "", "", "0", "", "", "", "", "2", "7.555", "0.114", "0.0055", "1.44658", "13.358", "0.133", "0.002", "1.37062", "0.00004", "0", "", "", "0015", "", "A", "81", "L", "94", "9", "54", "50.0", "90.0", "98.6", "", "", "", "", "96.9"]} +{"pcdb_id": 19052, "brand_name": "Keston", "model_name": "KESTON COMBI2", "model_qualifier": "C35", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 86.7, "comparative_hot_water_efficiency_pct": 69.4, "output_kw_max": 24.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.005, "loss_factor_f1_kwh_per_day": 1.48634, "loss_factor_f2_kwh_per_day": 1.28345, "rejected_factor_f3_per_litre": 3e-05, "raw": ["019052", "020099", "0", "2022/Oct/19 16:26", "Ideal Boilers", "Keston", "KESTON COMBI2", "C35", "47-930-10", "2022", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "A", "", "89.0", "86.7", "", "69.4", "", "2", "", "", "104", "1", "2", "28", "2", "0", "", "", "", "0", "", "", "", "", "2", "7.593", "0.117", "0.005", "1.48634", "13.633", "0.137", "0.0025", "1.28345", "0.00003", "0", "", "", "0015", "", "A", "79", "L", "94", "26", "85", "50.0", "90.0", "98.6", "", "", "", "", "96.9"]} +{"pcdb_id": 19053, "brand_name": "Keston", "model_name": "KESTON SYSTEM2", "model_qualifier": "S30", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 30.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["019053", "020099", "0", "2022/Oct/19 12:32", "Ideal Boilers", "Keston", "KESTON SYSTEM2", "S30", "41-930-54", "2022", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "30", "30", "A", "", "88.9", "79.9", "", "58.3", "", "2", "", "", "102", "1", "2", "52", "1", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0015", "", "", "", "", "93", "12", "62", "50.0", "89.8", "98.2", "", "", "", "", "96.6"]} +{"pcdb_id": 19054, "brand_name": "i-mini", "model_name": "i-mini2", "model_qualifier": "c35", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 86.6, "comparative_hot_water_efficiency_pct": 69.3, "output_kw_max": 24.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.0135, "loss_factor_f1_kwh_per_day": 1.44344, "loss_factor_f2_kwh_per_day": 1.23652, "rejected_factor_f3_per_litre": 8e-05, "raw": ["019054", "020099", "0", "2022/Oct/20 08:47", "Ideal Boilers", "i-mini", "i-mini2", "c35", "47-387-17", "2022", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "A", "", "89.0", "86.6", "", "69.3", "", "2", "", "", "104", "1", "2", "26", "2", "0", "", "", "", "0", "", "", "", "", "2", "7.6", "0.136", "0.0135", "1.44344", "13.634", "0.158", "0.006", "1.23652", "0.00008", "0", "", "", "0015", "", "A", "79", "L", "94", "12", "53", "50.0", "90.0", "98.6", "", "", "", "", "96.9"]} +{"pcdb_id": 19055, "brand_name": "Vokera By Riello", "model_name": "UNICA MAX", "model_qualifier": "35C", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 86.7, "comparative_hot_water_efficiency_pct": 77.0, "output_kw_max": 32.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0003, "loss_factor_f1_kwh_per_day": 0.73338, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["019055", "020088", "0", "2023/Jan/25 17:08", "Vokera Ltd.", "Vokera By Riello", "UNICA MAX", "35C", "47-364-61", "2021", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "32", "32", "A", "", "88.7", "86.7", "", "77.0", "", "2", "", "", "104", "1", "2", "49", "3", "0", "", "", "", "0", "", "", "", "", "1", "6.841", "0.104", "0.0003", "0.73338", "", "", "", "", "", "0", "", "", "0025", "", "A", "85", "XL", "94", "13", "75", "26.0", "87.9", "98.7", "", "", "", "", "96.6"]} +{"pcdb_id": 19056, "brand_name": "SIME", "model_name": "MIA-", "model_qualifier": "30", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 88.2, "comparative_hot_water_efficiency_pct": 72.4, "output_kw_max": 23.9, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.0018, "loss_factor_f1_kwh_per_day": 1.16098, "loss_factor_f2_kwh_per_day": 1.12352, "rejected_factor_f3_per_litre": 1e-05, "raw": ["019056", "020132", "0", "2023/Jan/04 09:07", "FONDERIE SIME SPA", "SIME", "MIA-", "30", "47-283-90", "2022", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "4.4", "23.9", "A", "", "88.5", "88.2", "", "72.4", "", "2", "", "", "104", "1", "2", "43", "4", "0", "", "", "", "0", "", "", "", "", "2", "7.275", "0.135", "0.0018", "1.16098", "13.068", "0.194", "0.0011", "1.12352", "0.00001", "0", "0", "", "0025", "", "A", "86", "XL", "93", "12", "75", "82.0", "88.7", "97.8", "", "", "", "", "96.0"]} +{"pcdb_id": 19057, "brand_name": "Vokera By Riello", "model_name": "UNICA MAX", "model_qualifier": "40C", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 86.7, "comparative_hot_water_efficiency_pct": 77.2, "output_kw_max": 32.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0025, "loss_factor_f1_kwh_per_day": 0.70128, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["019057", "020088", "0", "2023/Jan/26 09:13", "Vokera Ltd.", "Vokera By Riello", "UNICA MAX", "40C", "47-364-62", "2021", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "32", "32", "A", "", "88.7", "86.7", "", "77.2", "", "2", "", "", "104", "1", "2", "49", "3", "0", "", "", "", "0", "", "", "", "", "1", "6.821", "0.115", "0.0025", "0.70128", "", "", "", "", "", "0", "", "", "0025", "", "A", "85", "XL", "94", "13", "75", "26.0", "87.9", "98.7", "", "", "", "", "96.6"]} +{"pcdb_id": 19058, "brand_name": "Vokera By Riello", "model_name": "evolve", "model_qualifier": "24C", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 56.3, "output_kw_max": 17.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["019058", "020088", "0", "2023/Jan/05 15:32", "Vokera Ltd.", "Vokera By Riello", "evolve", "24C", "47 364 56", "2017", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "5.03", "17.6", "A", "", "88.7", "80.1", "", "56.3", "", "2", "0", "2", "104", "1", "2", "28", "3", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "0", "", "0005", "", "A", "87", "XL", "94", "14", "65", "42.0", "90.0", "95.5", "", "", "", "", "94.5"]} +{"pcdb_id": 19059, "brand_name": "Vokera By Riello", "model_name": "Easi-Heat Plus", "model_qualifier": "29Ci", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 56.8, "output_kw_max": 5.9, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["019059", "020088", "0", "2023/Jan/09 13:18", "Vokera Ltd.", "Vokera By Riello", "Easi-Heat Plus", "29Ci", "47-364-48", "2019", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "5.9", "5.9", "A", "", "89.4", "80.8", "", "56.8", "", "2", "0", "2", "104", "1", "2", "38", "5.6", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "1", "0", "", "0025", "", "A", "84", "XL", "93", "15.3", "89", "35.0", "90.1", "97.3", "", "017896", "", "", "96.0"]} +{"pcdb_id": 19060, "brand_name": "Viessmann", "model_name": "VITODENS 200-W", "model_qualifier": "B2HA-60", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 55.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["019060", "020094", "0", "2023/Feb/21 18:50", "Viessmann Ltd", "Viessmann", "VITODENS 200-W", "B2HA-60", "", "2015", "current", "1", "2", "1", "1", "0", "", "", "2", "3", "2", "55.4", "55.4", "A", "", "88.8", "79.8", "", "58.3", "", "2", "", "", "102", "1", "2", "69", "4", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "2005", "", "", "", "", "94", "20", "107", "60.0", "88.6", "98.6", "", "", "", "", "96.7"]} +{"pcdb_id": 19061, "brand_name": "Ideal Heating", "model_name": "LOGIC HEAT2", "model_qualifier": "H18P", "winter_efficiency_pct": 90.0, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 59.2, "output_kw_max": 18.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["019061", "020099", "0", "2023/Mar/22 15:08", "Ideal Boilers", "Ideal Heating", "LOGIC HEAT2", "H18P", "41-860-12", "2022", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "18", "18", "A", "", "90.0", "81.0", "", "59.2", "", "2", "1", "", "102", "1", "2", "25", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0015", "", "", "", "", "93", "4", "35", "50.0", "91.8", "100.7", "", "", "", "", "99.0"]} +{"pcdb_id": 19062, "brand_name": "Ideal Heating", "model_name": "LOGIC HEAT2", "model_qualifier": "H24P", "winter_efficiency_pct": 90.1, "summer_efficiency_pct": 81.1, "comparative_hot_water_efficiency_pct": 59.2, "output_kw_max": 24.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["019062", "020099", "0", "2023/Mar/22 14:35", "Ideal Boilers", "Ideal Heating", "LOGIC HEAT2", "H24P", "41-860-13", "2022", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "24.2", "24.2", "A", "", "90.1", "81.1", "", "59.2", "", "2", "1", "", "102", "1", "2", "46", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0015", "", "", "", "", "94", "13", "67", "50.0", "92.0", "100.8", "", "", "", "", "99.1"]} +{"pcdb_id": 19063, "brand_name": "Ideal Heating", "model_name": "LOGIC HEAT2", "model_qualifier": "H30P", "winter_efficiency_pct": 89.9, "summer_efficiency_pct": 80.9, "comparative_hot_water_efficiency_pct": 59.1, "output_kw_max": 30.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["019063", "020099", "0", "2023/Mar/22 14:34", "Ideal Boilers", "Ideal Heating", "LOGIC HEAT2", "H30P", "41-860-14", "2022", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "30", "30", "A", "", "89.9", "80.9", "", "59.1", "", "2", "1", "", "102", "1", "2", "50", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0015", "", "", "", "", "93", "12", "67", "50.0", "91.8", "100.4", "", "", "", "", "98.8"]} +{"pcdb_id": 19064, "brand_name": "Ideal Heating", "model_name": "LOGIC MAX HEAT2", "model_qualifier": "H18P", "winter_efficiency_pct": 90.0, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 59.2, "output_kw_max": 18.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["019064", "020099", "0", "2023/Mar/22 14:34", "Ideal Boilers", "Ideal Heating", "LOGIC MAX HEAT2", "H18P", "41-860-27", "2022", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "18", "18", "A", "", "90.0", "81.0", "", "59.2", "", "2", "1", "", "102", "1", "2", "25", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0015", "", "", "", "", "93", "23", "77", "50.0", "91.8", "100.7", "", "", "", "", "99.0"]} +{"pcdb_id": 19065, "brand_name": "Ideal Heating", "model_name": "LOGIC MAX HEAT2", "model_qualifier": "H24P", "winter_efficiency_pct": 90.1, "summer_efficiency_pct": 81.1, "comparative_hot_water_efficiency_pct": 59.2, "output_kw_max": 24.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["019065", "020099", "0", "2023/Mar/22 14:33", "Ideal Boilers", "Ideal Heating", "LOGIC MAX HEAT2", "H24P", "41-860-28", "2022", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "24.2", "24.2", "A", "", "90.1", "81.1", "", "59.2", "", "2", "1", "", "102", "1", "2", "44", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0015", "", "", "", "", "94", "12", "64", "50.0", "92.0", "100.8", "", "", "", "", "99.1"]} +{"pcdb_id": 19066, "brand_name": "Ideal Heating", "model_name": "LOGIC MAX HEAT2", "model_qualifier": "H30P", "winter_efficiency_pct": 89.8, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 59.1, "output_kw_max": 30.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["019066", "020099", "0", "2023/Mar/22 14:33", "Ideal Boilers", "Ideal Heating", "LOGIC MAX HEAT2", "H30P", "41-860-29", "2022", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "30", "30", "A", "", "89.8", "80.8", "", "59.1", "", "2", "1", "", "102", "1", "2", "52", "1", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0015", "", "", "", "", "93", "12", "62", "50.0", "91.6", "100.4", "", "", "", "", "98.7"]} +{"pcdb_id": 19067, "brand_name": "Ideal Heating", "model_name": "LOGIC SYSTEM2", "model_qualifier": "S18P", "winter_efficiency_pct": 90.0, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 59.2, "output_kw_max": 18.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["019067", "020099", "0", "2023/Mar/22 14:33", "Ideal Boilers", "Ideal Heating", "LOGIC SYSTEM2", "S18P", "41-796-86", "2022", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "18", "18", "A", "", "90.0", "81.0", "", "59.2", "", "2", "1", "", "102", "1", "2", "25", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0015", "", "", "", "", "93", "3", "33", "50.0", "91.8", "100.7", "", "", "", "", "99.0"]} +{"pcdb_id": 19068, "brand_name": "Ideal Heating", "model_name": "LOGIC SYSTEM2", "model_qualifier": "S30P", "winter_efficiency_pct": 89.9, "summer_efficiency_pct": 80.9, "comparative_hot_water_efficiency_pct": 59.1, "output_kw_max": 30.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["019068", "020099", "0", "2023/Mar/22 14:31", "Ideal Boilers", "Ideal Heating", "LOGIC SYSTEM2", "S30P", "41-796-88", "2022", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "30", "30", "A", "", "89.9", "80.9", "", "59.1", "", "2", "1", "", "102", "1", "2", "50", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0015", "", "", "", "", "93", "12", "67", "50.0", "91.8", "100.4", "", "", "", "", "98.8"]} +{"pcdb_id": 19069, "brand_name": "Ideal Heating", "model_name": "LOGIC MAX SYSTEM2", "model_qualifier": "S18P", "winter_efficiency_pct": 90.0, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 59.2, "output_kw_max": 18.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["019069", "020099", "0", "2023/Mar/22 14:30", "Ideal Boilers", "Ideal Heating", "LOGIC MAX SYSTEM2", "S18P", "41-796-98", "2022", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "18", "18", "A", "", "90.0", "81.0", "", "59.2", "", "2", "1", "", "102", "1", "2", "25", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0015", "", "", "", "", "93", "23", "77", "50.0", "91.8", "100.7", "", "", "", "", "99.0"]} +{"pcdb_id": 19070, "brand_name": "Ideal Heating", "model_name": "LOGIC MAX SYSTEM2", "model_qualifier": "S24P", "winter_efficiency_pct": 90.1, "summer_efficiency_pct": 81.1, "comparative_hot_water_efficiency_pct": 59.2, "output_kw_max": 24.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["019070", "020099", "0", "2023/Mar/22 14:30", "Ideal Boilers", "Ideal Heating", "LOGIC MAX SYSTEM2", "S24P", "41-796-99", "2022", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "24.3", "24.3", "A", "", "90.1", "81.1", "", "59.2", "", "2", "1", "", "102", "1", "2", "44", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0015", "", "", "", "", "94", "12", "64", "50.0", "92.0", "100.8", "", "", "", "", "99.1"]} +{"pcdb_id": 19071, "brand_name": "Ideal Heating", "model_name": "LOGIC MAX SYSTEM2", "model_qualifier": "S30P", "winter_efficiency_pct": 89.8, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 59.0, "output_kw_max": 30.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["019071", "020099", "0", "2023/Mar/22 14:29", "Ideal Boilers", "Ideal Heating", "LOGIC MAX SYSTEM2", "S30P", "41-860-01", "2022", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "30", "30", "A", "", "89.8", "80.8", "", "59.0", "", "2", "1", "", "102", "1", "2", "52", "1", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0015", "", "", "", "", "93", "12", "62", "50.0", "91.8", "100.3", "", "", "", "", "98.7"]} +{"pcdb_id": 19072, "brand_name": "SIME", "model_name": "GIULIA COMBI", "model_qualifier": "30", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 76.3, "comparative_hot_water_efficiency_pct": 72.8, "output_kw_max": 30.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.0099, "loss_factor_f1_kwh_per_day": 1.07739, "loss_factor_f2_kwh_per_day": 0.10228, "rejected_factor_f3_per_litre": 4e-05, "raw": ["019072", "020132", "0", "2023/Mar/31 10:32", "FONDERIE SIME SPA", "SIME", "GIULIA COMBI", "30", "47-283-93", "2023", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "4.8", "30", "A", "", "88.6", "76.3", "", "72.8", "", "2", "", "", "104", "1", "2", "35", "4", "0", "", "", "", "0", "", "", "", "", "2", "7.235", "0.149", "0.0099", "1.07739", "14.109", "0.175", "0.006", "0.10228", "0.00004", "0", "", "", "0025", "", "A", "82", "XL", "93", "11", "68", "82.0", "88.7", "97.9", "", "", "", "", "96.2"]} +{"pcdb_id": 19073, "brand_name": "SIME", "model_name": "GIULIA SYSTEM", "model_qualifier": "25", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 24.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["019073", "020132", "0", "2023/Mar/31 10:37", "FONDERIE SIME SPA", "SIME", "GIULIA SYSTEM", "25", "41-283-66", "2023", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "4.8", "24", "A", "", "88.6", "79.6", "", "58.1", "", "2", "", "", "102", "1", "2", "35", "4", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "93", "11", "68", "82.0", "88.7", "97.9", "", "", "", "", "96.2"]} +{"pcdb_id": 19074, "brand_name": "Sapphire", "model_name": "Sapphire 28 HVO", "model_qualifier": "", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 81.1, "comparative_hot_water_efficiency_pct": 59.2, "output_kw_max": 28.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["019074", "020153", "0", "2023/May/11 17:16", "EOGB Energy Products ltd", "Sapphire", "Sapphire 28 HVO", "", "", "2021", "current", "71", "1", "1", "1", "0", "", "", "2", "2", "2", "28", "28", "A", "", "88.9", "81.1", "", "59.2", "", "2", "", "", "201", "1", "2", "117", "6", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "4015", "", "", "", "", "93", "27", "162", "49.0", "91.5", "96.8", "", "018903", "", "", "95.8"]} +{"pcdb_id": 19075, "brand_name": "Sapphire", "model_name": "Sapphire 23 HVO", "model_qualifier": "", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 80.9, "comparative_hot_water_efficiency_pct": 59.1, "output_kw_max": 23.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["019075", "020153", "0", "2023/May/11 17:22", "EOGB Energy Products ltd", "Sapphire", "Sapphire 23 HVO", "", "", "2021", "current", "71", "1", "1", "1", "0", "", "", "2", "2", "2", "7.08", "23.4", "A", "", "88.7", "80.9", "", "59.1", "", "2", "", "", "201", "1", "2", "133", "6", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "4005", "", "", "", "", "92", "27", "172", "49.0", "92.6", "95.9", "", "018906", "", "", "95.2"]} +{"pcdb_id": 19076, "brand_name": "Baxi", "model_name": "624 COMBI 2", "model_qualifier": "", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 86.8, "comparative_hot_water_efficiency_pct": 80.4, "output_kw_max": 22.9, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0029, "loss_factor_f1_kwh_per_day": 0.44307, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["019076", "020101", "0", "2023/Jun/27 14:55", "Baxi Heating", "Baxi", "624 COMBI 2", "", "47-077-55", "2023", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "22.9", "22.9", "A", "", "88.9", "86.8", "", "80.4", "", "2", "", "", "104", "1", "2", "46", "4", "0", "", "", "", "0", "", "", "", "", "1", "6.548", "0.074", "0.0029", "0.44307", "", "", "", "", "", "0", "", "", "0405", "", "A", "93", "XL", "94", "8", "68", "40.0", "88.2", "99.0", "", "", "", "", "97.0"]} +{"pcdb_id": 19077, "brand_name": "Baxi", "model_name": "630 COMBI 2", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 86.7, "comparative_hot_water_efficiency_pct": 81.3, "output_kw_max": 28.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0021, "loss_factor_f1_kwh_per_day": 0.37197, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["019077", "020101", "0", "2023/Jun/27 15:46", "Baxi Heating", "Baxi", "630 COMBI 2", "", "47-077-56", "2023", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28.6", "28.6", "A", "", "88.8", "86.7", "", "81.3", "", "2", "", "", "104", "1", "2", "61", "4", "0", "", "", "", "0", "", "", "", "", "1", "6.474", "0.071", "0.0021", "0.37197", "", "", "", "", "", "0", "", "", "0405", "", "A", "93", "XL", "94", "9", "79", "40.0", "88.0", "98.9", "", "", "", "", "96.9"]} +{"pcdb_id": 19078, "brand_name": "Baxi", "model_name": "636 COMBI 2", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 86.7, "comparative_hot_water_efficiency_pct": 81.4, "output_kw_max": 28.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0021, "loss_factor_f1_kwh_per_day": 0.37024, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["019078", "020101", "0", "2023/Jun/27 14:53", "Baxi Heating", "Baxi", "636 COMBI 2", "", "47-077-57", "2023", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28.6", "28.6", "A", "", "88.8", "86.7", "", "81.4", "", "2", "", "", "104", "1", "2", "71", "4", "0", "", "", "", "0", "", "", "", "", "1", "6.47", "0.071", "0.0021", "0.37024", "", "", "", "", "", "0", "", "", "0405", "", "A", "93", "XL", "94", "9", "85", "40.0", "88.1", "98.8", "", "", "", "", "96.8"]} +{"pcdb_id": 19079, "brand_name": "Baxi", "model_name": "ASSURE 524 COMBI 2", "model_qualifier": "", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 86.8, "comparative_hot_water_efficiency_pct": 80.4, "output_kw_max": 22.9, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0029, "loss_factor_f1_kwh_per_day": 0.44307, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["019079", "020101", "0", "2023/Jun/27 14:52", "Baxi Heating", "Baxi", "ASSURE 524 COMBI 2", "", "47-077-59", "2023", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "22.9", "22.9", "A", "", "88.9", "86.8", "", "80.4", "", "2", "", "", "104", "1", "2", "46", "4", "0", "", "", "", "0", "", "", "", "", "1", "6.548", "0.074", "0.0029", "0.44307", "", "", "", "", "", "0", "", "", "0405", "", "A", "93", "XL", "94", "8", "68", "40.0", "88.2", "99.0", "", "", "", "", "97.0"]} +{"pcdb_id": 19080, "brand_name": "Baxi", "model_name": "ASSURE 530 COMBI 2", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 86.7, "comparative_hot_water_efficiency_pct": 81.3, "output_kw_max": 28.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0021, "loss_factor_f1_kwh_per_day": 0.37197, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["019080", "020101", "0", "2023/Jun/27 14:47", "Baxi Heating UK Ltd", "Baxi", "ASSURE 530 COMBI 2", "", "47-077-60", "2023", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28.6", "28.6", "A", "", "88.8", "86.7", "", "81.3", "", "2", "", "", "104", "1", "2", "61", "4", "0", "", "", "", "0", "", "", "", "", "1", "6.474", "0.071", "0.0021", "0.37197", "", "", "", "", "", "0", "", "", "0405", "", "A", "93", "XL", "94", "9", "79", "40.0", "88.0", "98.9", "", "", "", "", "96.9"]} +{"pcdb_id": 19081, "brand_name": "Baxi", "model_name": "ASSURE 536 COMBI 2", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 86.7, "comparative_hot_water_efficiency_pct": 81.4, "output_kw_max": 28.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0021, "loss_factor_f1_kwh_per_day": 0.37024, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["019081", "020101", "0", "2023/Jun/27 14:59", "Baxi Heating UK Ltd", "Baxi", "ASSURE 536 COMBI 2", "", "47-077-61", "2023", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28.6", "28.6", "A", "", "88.8", "86.7", "", "81.4", "", "2", "", "", "104", "1", "2", "71", "4", "0", "", "", "", "0", "", "", "", "", "1", "6.47", "0.071", "0.0021", "0.37024", "", "", "", "", "", "0", "", "", "0405", "", "A", "93", "XL", "94", "9", "85", "40.0", "88.1", "98.8", "", "", "", "", "96.8"]} +{"pcdb_id": 19082, "brand_name": "Baxi", "model_name": "824 COMBI 2", "model_qualifier": "", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 86.8, "comparative_hot_water_efficiency_pct": 80.4, "output_kw_max": 22.9, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0029, "loss_factor_f1_kwh_per_day": 0.44307, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["019082", "020101", "0", "2023/Jun/27 15:01", "Baxi Heating UK Ltd", "Baxi", "824 COMBI 2", "", "47-077-63", "2023", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "22.9", "22.9", "A", "", "88.9", "86.8", "", "80.4", "", "2", "", "", "104", "1", "2", "46", "4", "0", "", "", "", "0", "", "", "", "", "1", "6.548", "0.074", "0.0029", "0.44307", "", "", "", "", "", "0", "", "", "0405", "", "A", "93", "XL", "94", "8", "68", "40.0", "88.2", "99.0", "", "", "", "", "97.0"]} +{"pcdb_id": 19083, "brand_name": "Baxi", "model_name": "830 COMBI 2", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 86.7, "comparative_hot_water_efficiency_pct": 81.3, "output_kw_max": 28.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0021, "loss_factor_f1_kwh_per_day": 0.37197, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["019083", "020101", "0", "2023/Jun/27 15:04", "Baxi Heating UK Ltd", "Baxi", "830 COMBI 2", "", "47-077-64", "2023", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28.6", "28.6", "A", "", "88.8", "86.7", "", "81.3", "", "2", "", "", "104", "1", "2", "61", "4", "0", "", "", "", "0", "", "", "", "", "1", "6.474", "0.071", "0.0021", "0.37197", "", "", "", "", "", "0", "", "", "0405", "", "A", "93", "XL", "94", "9", "79", "40.0", "88.0", "98.9", "", "", "", "", "96.9"]} +{"pcdb_id": 19084, "brand_name": "Baxi", "model_name": "836 COMBI 2", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 86.7, "comparative_hot_water_efficiency_pct": 81.4, "output_kw_max": 28.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0021, "loss_factor_f1_kwh_per_day": 0.37024, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["019084", "020101", "0", "2023/Jun/27 15:45", "Baxi Heating UK Ltd", "Baxi", "836 COMBI 2", "", "47-077-65", "2023", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28.6", "28.6", "A", "", "88.8", "86.7", "", "81.4", "", "2", "", "", "104", "1", "2", "71", "4", "0", "", "", "", "0", "", "", "", "", "1", "6.47", "0.071", "0.0021", "0.37024", "", "", "", "", "", "0", "", "", "0405", "", "A", "93", "XL", "94", "9", "85", "40.0", "88.1", "98.8", "", "", "", "", "96.8"]} +{"pcdb_id": 19085, "brand_name": "Baxi", "model_name": "615 SYSTEM 2", "model_qualifier": "", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 17.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["019085", "020101", "0", "2023/Jun/27 15:08", "Baxi Heating UK Ltd", "Baxi", "615 SYSTEM 2", "", "41-884-01", "2023", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "17.2", "17.2", "A", "", "88.9", "79.9", "", "58.4", "", "2", "", "", "102", "1", "2", "16", "4", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "94", "8", "51", "40.0", "88.2", "99.0", "", "", "", "", "97.0"]} +{"pcdb_id": 19086, "brand_name": "Baxi", "model_name": "618 SYSTEM 2", "model_qualifier": "", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 20.7, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["019086", "020101", "0", "2023/Jun/27 15:14", "Baxi Heating UK Ltd", "Baxi", "618 SYSTEM 2", "", "41-884-02", "2023", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "20.7", "20.7", "A", "", "88.9", "79.9", "", "58.4", "", "2", "", "", "102", "1", "2", "26", "4", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "94", "8", "56", "40.0", "88.2", "99.0", "", "", "", "", "97.0"]} +{"pcdb_id": 19087, "brand_name": "Baxi", "model_name": "624 SYSTEM 2", "model_qualifier": "", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 27.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["019087", "020101", "0", "2023/Jun/27 15:16", "Baxi Heating UK Ltd", "Baxi", "624 SYSTEM 2", "", "41-884-03", "2023", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "27.4", "27.4", "A", "", "88.9", "79.9", "", "58.4", "", "2", "", "", "102", "1", "2", "46", "4", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "94", "8", "68", "40.0", "88.2", "99.0", "", "", "", "", "97.0"]} +{"pcdb_id": 19088, "brand_name": "Baxi", "model_name": "818 SYSTEM 2", "model_qualifier": "", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 20.7, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["019088", "020101", "0", "2023/Jun/27 15:18", "Baxi Heating UK Ltd", "Baxi", "818 SYSTEM 2", "", "41-470-99", "2023", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "20.7", "20.7", "A", "", "88.9", "79.9", "", "58.4", "", "2", "", "", "102", "1", "2", "26", "4", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "94", "8", "56", "40.0", "88.2", "99.0", "", "", "", "", "97.0"]} +{"pcdb_id": 19089, "brand_name": "Baxi", "model_name": "824 SYSTEM 2", "model_qualifier": "", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 27.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["019089", "020101", "0", "2023/Jun/27 15:20", "Baxi Heating UK Ltd", "Baxi", "824 SYSTEM 2", "", "41-884-09", "2023", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "27.4", "27.4", "A", "", "88.9", "79.9", "", "58.4", "", "2", "", "", "102", "1", "2", "46", "4", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "94", "8", "68", "40.0", "88.2", "99.0", "", "", "", "", "97.0"]} +{"pcdb_id": 19090, "brand_name": "Baxi", "model_name": "830 SYSTEM 2", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 34.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["019090", "020101", "0", "2023/Jun/27 15:21", "Baxi Heating UK Ltd", "Baxi", "830 SYSTEM 2", "", "41-884-08", "2023", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "34.3", "34.3", "A", "", "88.8", "79.8", "", "58.3", "", "2", "", "", "102", "1", "2", "71", "4", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "94", "9", "85", "40.0", "87.9", "98.8", "", "", "", "", "96.8"]} +{"pcdb_id": 19091, "brand_name": "Baxi", "model_name": "ASSURE 515 SYSTEM 2", "model_qualifier": "", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 17.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["019091", "020101", "0", "2023/Jun/27 15:25", "Baxi Heating UK Ltd", "Baxi", "ASSURE 515 SYSTEM 2", "", "41-844-04", "2023", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "17.2", "17.2", "A", "", "88.9", "79.9", "", "58.4", "", "2", "", "", "102", "1", "2", "16", "4", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "94", "8", "51", "40.0", "88.2", "99.0", "", "", "", "", "97.0"]} +{"pcdb_id": 19092, "brand_name": "Baxi", "model_name": "ASSURE 518 SYSTEM 2", "model_qualifier": "", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 20.7, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["019092", "020101", "0", "2023/Jun/27 15:42", "Baxi Heating UK Ltd", "Baxi", "ASSURE 518 SYSTEM 2", "", "41-844-05", "2023", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "20.7", "20.7", "A", "", "88.9", "79.9", "", "58.4", "", "2", "", "", "102", "1", "2", "26", "4", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "94", "8", "56", "40.0", "88.2", "99.0", "", "", "", "", "97.0"]} +{"pcdb_id": 19093, "brand_name": "Baxi", "model_name": "ASSURE 524 SYSTEM 2", "model_qualifier": "", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 27.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["019093", "020101", "0", "2023/Jun/27 15:27", "Baxi Heating UK Ltd", "Baxi", "ASSURE 524 SYSTEM 2", "", "41-844-06", "2023", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "27.4", "27.4", "A", "", "88.9", "79.9", "", "58.4", "", "2", "", "", "102", "1", "2", "46", "4", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "94", "8", "68", "40.0", "88.2", "99.0", "", "", "", "", "97.0"]} +{"pcdb_id": 19094, "brand_name": "Worcester", "model_name": "Greenstar 2000", "model_qualifier": "GR2301iW 30 C NG", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 88.2, "comparative_hot_water_efficiency_pct": 70.2, "output_kw_max": 24.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.0032, "loss_factor_f1_kwh_per_day": 1.35468, "loss_factor_f2_kwh_per_day": 1.33322, "rejected_factor_f3_per_litre": 1e-05, "raw": ["019094", "020051", "0", "2023/Jul/13 15:21", "Bosch Thermotechnology Ltd", "Worcester", "Greenstar 2000", "GR2301iW 30 C NG", "47-800-36", "2023", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "A", "", "88.7", "88.2", "", "70.2", "", "2", "", "", "104", "1", "2", "37", "3", "0", "", "", "", "0", "", "", "", "", "2", "7.502", "0.104", "0.0032", "1.35468", "13.279", "0.122", "0.0023", "1.33322", "0.00001", "0", "", "", "8305", "", "A", "84", "XL", "94", "12", "66", "55.0", "88.0", "98.6", "", "", "", "", "96.6"]} +{"pcdb_id": 19095, "brand_name": "Worcester", "model_name": "Greenstar 2000", "model_qualifier": "GR2301iW 25 C NG", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 88.2, "comparative_hot_water_efficiency_pct": 74.4, "output_kw_max": 24.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.0048, "loss_factor_f1_kwh_per_day": 0.94216, "loss_factor_f2_kwh_per_day": 0.92191, "rejected_factor_f3_per_litre": 3e-05, "raw": ["019095", "020051", "0", "2023/Jul/13 15:21", "Bosch Thermotechnology Ltd", "Worcester", "Greenstar 2000", "GR2301iW 25 C NG", "47-800-34", "2023", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "A", "", "88.7", "88.2", "", "74.4", "", "2", "", "", "104", "1", "2", "37", "3", "0", "", "", "", "0", "", "", "", "", "2", "7.083", "0.103", "0.0048", "0.94216", "12.72", "0.124", "0.0016", "0.92191", "0.00003", "0", "", "", "8305", "", "A", "84", "XL", "94", "12", "66", "55.0", "88.0", "98.6", "", "", "", "", "96.6"]} +{"pcdb_id": 19096, "brand_name": "Worcester", "model_name": "Greenstar 2000", "model_qualifier": "GR2301iW 30 C LPG", "winter_efficiency_pct": 89.8, "summer_efficiency_pct": 90.3, "comparative_hot_water_efficiency_pct": 72.0, "output_kw_max": 24.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.0047, "loss_factor_f1_kwh_per_day": 1.31385, "loss_factor_f2_kwh_per_day": 1.31111, "rejected_factor_f3_per_litre": 5e-05, "raw": ["019096", "020051", "0", "2023/Jul/13 15:22", "Bosch Thermotechnology Ltd", "Worcester", "Greenstar 2000", "GR2301iW 30 C LPG", "47-800-37", "2023", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "A", "", "89.8", "90.3", "", "72.0", "", "2", "0", "2", "104", "1", "2", "37", "3", "0", "", "", "", "0", "", "", "", "", "2", "7.476", "0.096", "0.0047", "1.31385", "13.022", "0.113", "0.0002", "1.31111", "0.00005", "0", "", "", "8305", "", "A", "84", "XL", "94", "12", "66", "55.0", "89.7", "98.5", "", "", "", "", "96.8"]} +{"pcdb_id": 19097, "brand_name": "Worcester", "model_name": "Greenstar 2000", "model_qualifier": "GR2301iW 25 C LPG", "winter_efficiency_pct": 89.8, "summer_efficiency_pct": 90.3, "comparative_hot_water_efficiency_pct": 74.2, "output_kw_max": 24.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.0004, "loss_factor_f1_kwh_per_day": 1.12367, "loss_factor_f2_kwh_per_day": 1.12102, "rejected_factor_f3_per_litre": -1e-05, "raw": ["019097", "020051", "0", "2023/Jul/13 15:24", "Bosch Thermotechnology Ltd", "Worcester", "Greenstar 2000", "GR2301iW 25 C LPG", "47-800-35", "2023", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "A", "", "89.8", "90.3", "", "74.2", "", "2", "0", "2", "104", "1", "2", "37", "3", "0", "", "", "", "0", "", "", "", "", "2", "7.252", "0.094", "0.0004", "1.12367", "13.176", "0.113", "0.0013", "1.12102", "-0.00001", "", "", "", "8305", "", "A", "84", "XL", "94", "12", "66", "55.0", "89.7", "98.5", "", "", "", "", "96.8"]} +{"pcdb_id": 19098, "brand_name": "Vokera By Riello", "model_name": "evolve", "model_qualifier": "18S LPG", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 18.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["019098", "020088", "0", "2023/Aug/04 14:52", "Vokera Ltd.", "Vokera By Riello", "evolve", "18S LPG", "47-364-09", "2018", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "18", "18", "A", "", "88.7", "79.7", "", "58.2", "", "2", "0", "2", "102", "1", "2", "28", "3", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "94", "14", "65", "42.0", "90.0", "95.5", "", "", "", "", "94.5"]} +{"pcdb_id": 19099, "brand_name": "Alpha Innovation", "model_name": "E-Tec NX", "model_qualifier": "28", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 82.7, "comparative_hot_water_efficiency_pct": 69.5, "output_kw_max": 24.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.0057, "loss_factor_f1_kwh_per_day": 1.41374, "loss_factor_f2_kwh_per_day": 0.93333, "rejected_factor_f3_per_litre": 4e-05, "raw": ["019099", "020029", "0", "2023/Aug/11 11:38", "Immergas", "Alpha Innovation", "E-Tec NX", "28", "3.033112", "2023", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "A", "", "88.8", "82.7", "", "69.5", "", "2", "", "", "104", "1", "2", "12", "2", "0", "", "", "", "0", "", "", "", "", "2", "7.576", "0.069", "0.0057", "1.41374", "13.894", "0.086", "0.0017", "0.93333", "0.00004", "0", "", "", "1005", "", "A", "87", "XL", "94", "6", "32", "54.0", "88.1", "98.7", "", "", "", "", "96.7"]} +{"pcdb_id": 19100, "brand_name": "Alpha Innovation", "model_name": "E-Tec NX", "model_qualifier": "33", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 70.3, "output_kw_max": 28.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.0021, "loss_factor_f1_kwh_per_day": 1.35105, "loss_factor_f2_kwh_per_day": 0.64996, "rejected_factor_f3_per_litre": -1e-05, "raw": ["019100", "020029", "0", "2023/Aug/11 11:49", "Immergas", "Alpha Innovation", "E-Tec NX", "33", "3.033113", "2023", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28", "28", "A", "", "88.8", "79.9", "", "70.3", "", "2", "", "", "104", "1", "2", "13", "2", "0", "", "", "", "0", "", "", "", "", "2", "7.489", "0.077", "0.0021", "1.35105", "14.074", "0.1", "0.0035", "0.64996", "-0.00001", "0", "", "", "1005", "", "A", "87", "XL", "94", "6", "33", "54.0", "88.1", "98.7", "", "", "", "", "96.7"]} +{"pcdb_id": 19101, "brand_name": "Alpha Innovation", "model_name": "Evoke NX", "model_qualifier": "28", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 82.7, "comparative_hot_water_efficiency_pct": 69.5, "output_kw_max": 24.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.0057, "loss_factor_f1_kwh_per_day": 1.41374, "loss_factor_f2_kwh_per_day": 0.93401, "rejected_factor_f3_per_litre": 4e-05, "raw": ["019101", "020029", "0", "2023/Aug/11 12:00", "Immergas", "Alpha Innovation", "Evoke NX", "28", "3.033114", "2023", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "A", "", "88.8", "82.7", "", "69.5", "", "2", "", "", "104", "1", "2", "12", "2", "0", "", "", "", "0", "", "", "", "", "2", "7.576", "0.069", "0.0057", "1.41374", "13.894", "0.086", "0.0018", "0.93401", "0.00004", "0", "", "", "1005", "", "A", "87", "XL", "94", "6", "32", "54.0", "88.1", "98.7", "", "", "", "", "96.7"]} +{"pcdb_id": 19102, "brand_name": "Alpha Innovation", "model_name": "Evoke NX", "model_qualifier": "33", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 70.3, "output_kw_max": 28.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.0021, "loss_factor_f1_kwh_per_day": 1.35105, "loss_factor_f2_kwh_per_day": 0.64996, "rejected_factor_f3_per_litre": -1e-05, "raw": ["019102", "020029", "0", "2023/Aug/11 12:06", "Immergas", "Alpha Innovation", "Evoke NX", "33", "3.033115", "2023", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28", "28", "A", "", "88.8", "79.9", "", "70.3", "", "2", "", "", "104", "1", "2", "13", "2", "0", "", "", "", "0", "", "", "", "", "2", "7.489", "0.077", "0.0021", "1.35105", "14.074", "0.1", "0.0035", "0.64996", "-0.00001", "", "", "", "1005", "", "A", "87", "XL", "94", "6", "33", "54.0", "88.1", "98.7", "", "", "", "", "96.7"]} +{"pcdb_id": 19103, "brand_name": "Alpha Innovation", "model_name": "E-Tec NXS", "model_qualifier": "20", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 24.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["019103", "020029", "0", "2023/Aug/11 12:18", "Immergas", "Alpha Innovation", "E-Tec NXS", "20", "3.033117", "2023", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24", "24", "A", "", "88.8", "79.8", "", "58.3", "", "2", "", "", "102", "1", "2", "12", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "1005", "", "", "", "", "94", "6", "32", "54.0", "88.1", "98.7", "", "", "", "", "96.7"]} +{"pcdb_id": 19104, "brand_name": "Alpha Innovation", "model_name": "E-Tec NXS", "model_qualifier": "30", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 28.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["019104", "020029", "0", "2023/Aug/11 12:24", "Immergas", "Alpha Innovation", "E-Tec NXS", "30", "3.033119", "2023", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "28", "28", "A", "", "88.8", "79.8", "", "58.3", "", "2", "", "", "102", "1", "2", "13", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "1005", "", "", "", "", "94", "6", "33", "54.0", "88.1", "98.7", "", "", "", "", "96.7"]} +{"pcdb_id": 19105, "brand_name": "Alpha Innovation", "model_name": "E-Tec NXS", "model_qualifier": "35", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 32.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["019105", "020029", "0", "2023/Aug/11 12:30", "Immergas", "Alpha Innovation", "E-Tec NXS", "35", "3.033120", "2023", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "32", "32", "A", "", "88.8", "79.8", "", "58.3", "", "2", "", "", "102", "1", "2", "20", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "1005", "", "", "", "", "94", "10", "45", "54.0", "88.1", "98.7", "", "", "", "", "96.7"]} +{"pcdb_id": 19106, "brand_name": "Alpha Innovation", "model_name": "E-Tec Plus NX", "model_qualifier": "28", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 82.7, "comparative_hot_water_efficiency_pct": 69.5, "output_kw_max": 24.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.0057, "loss_factor_f1_kwh_per_day": 1.41374, "loss_factor_f2_kwh_per_day": 0.93333, "rejected_factor_f3_per_litre": 4e-05, "raw": ["019106", "020029", "0", "2023/Sep/11 16:46", "Immergas", "Alpha Innovation", "E-Tec Plus NX", "28", "3.033121", "2023", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "A", "", "88.8", "82.7", "", "69.5", "", "2", "", "", "104", "1", "2", "12", "2", "0", "", "", "", "0", "", "", "", "", "2", "7.576", "0.069", "0.0057", "1.41374", "13.894", "0.086", "0.0017", "0.93333", "0.00004", "0", "", "", "1005", "", "A", "87", "XL", "94", "6", "32", "54.0", "88.1", "98.7", "", "", "", "", "96.7"]} +{"pcdb_id": 19107, "brand_name": "Alpha Innovation", "model_name": "E-Tec Plus NX", "model_qualifier": "33", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 70.3, "output_kw_max": 28.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.0021, "loss_factor_f1_kwh_per_day": 1.35105, "loss_factor_f2_kwh_per_day": 0.64996, "rejected_factor_f3_per_litre": -1e-05, "raw": ["019107", "020029", "0", "2023/Sep/11 16:54", "Immergas", "Alpha Innovation", "E-Tec Plus NX", "33", "3.033122", "2023", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "28", "28", "A", "", "88.8", "79.9", "", "70.3", "", "2", "", "", "104", "1", "2", "13", "2", "0", "", "", "", "0", "", "", "", "", "2", "7.489", "0.077", "0.0021", "1.35105", "14.074", "0.1", "0.0035", "0.64996", "-0.00001", "0", "", "", "1005", "", "A", "87", "XL", "94", "6", "33", "54.0", "88.1", "98.7", "", "", "", "", "96.7"]} +{"pcdb_id": 19108, "brand_name": "Alpha Innovation", "model_name": "E-Tec Plus NX", "model_qualifier": "38", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 86.7, "comparative_hot_water_efficiency_pct": 70.2, "output_kw_max": 32.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0053, "loss_factor_f1_kwh_per_day": 1.34033, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["019108", "020029", "0", "2023/Sep/12 11:53", "Immergas", "Alpha Innovation", "E-Tec Plus NX", "38", "3.033123", "2023", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "32", "32", "A", "", "88.8", "86.7", "", "70.2", "", "2", "", "", "104", "1", "2", "20", "2", "0", "", "", "", "0", "", "", "", "", "1", "7.497", "0.129", "0.0053", "1.34033", "", "", "", "", "", "0", "", "", "1005", "", "A", "85", "XXL", "94", "10", "45", "54.0", "88.1", "98.7", "", "", "", "", "96.7"]} +{"pcdb_id": 19109, "brand_name": "Worcester", "model_name": "Greenstar 1000", "model_qualifier": "GR1000W 24 C NG", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 88.2, "comparative_hot_water_efficiency_pct": 75.2, "output_kw_max": 24.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.0028, "loss_factor_f1_kwh_per_day": 0.8686, "loss_factor_f2_kwh_per_day": 0.85316, "rejected_factor_f3_per_litre": 2e-05, "raw": ["019109", "020051", "0", "2023/Oct/06 15:23", "Bosch Thermotechnology Ltd", "Worcester", "Greenstar 1000", "GR1000W 24 C NG", "47-800-38", "2023", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "A", "", "88.6", "88.2", "", "75.2", "", "2", "", "", "104", "1", "2", "42", "3", "0", "", "", "", "0", "", "", "", "", "2", "6.999", "0.114", "0.0028", "0.8686", "12.563", "0.141", "0.001", "0.85316", "0.00002", "0", "", "", "8305", "", "A", "84", "XL", "94", "11", "66", "51.0", "87.8", "98.5", "", "", "", "", "96.5"]} +{"pcdb_id": 19110, "brand_name": "Worcester", "model_name": "Greenstar 1000", "model_qualifier": "GR1000W 30 C NG", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 88.2, "comparative_hot_water_efficiency_pct": 75.7, "output_kw_max": 24.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.0022, "loss_factor_f1_kwh_per_day": 0.82108, "loss_factor_f2_kwh_per_day": 0.81257, "rejected_factor_f3_per_litre": 1e-05, "raw": ["019110", "020051", "0", "2023/Oct/06 15:25", "Bosch Thermotechnology Ltd", "Worcester", "Greenstar 1000", "GR1000W 30 C NG", "47-800-39", "2023", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "A", "", "88.3", "88.2", "", "75.7", "", "2", "", "", "104", "1", "2", "40", "3", "0", "", "", "", "0", "", "", "", "", "2", "6.953", "0.113", "0.0022", "0.82108", "12.699", "0.137", "0.0009", "0.81257", "0.00001", "0", "", "", "8305", "", "A", "84", "XL", "94", "12", "67", "51.0", "87.6", "97.8", "", "", "", "", "95.9"]} +{"pcdb_id": 19111, "brand_name": "Morco", "model_name": "IV", "model_qualifier": "GB24 PROPANE", "winter_efficiency_pct": 90.1, "summer_efficiency_pct": 90.3, "comparative_hot_water_efficiency_pct": 71.7, "output_kw_max": 24.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.0045, "loss_factor_f1_kwh_per_day": 1.40589, "loss_factor_f2_kwh_per_day": 1.34178, "rejected_factor_f3_per_litre": 3e-05, "raw": ["019111", "020099", "0", "2023/Oct/20 15:38", "Ideal Boilers", "Morco", "IV", "GB24 PROPANE", "236485", "2023", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "A", "", "90.1", "90.3", "", "71.7", "", "2", "1", "", "104", "1", "2", "29", "3", "0", "", "", "", "0", "", "", "", "", "2", "7.507", "0.146", "0.0045", "1.40589", "13.369", "0.166", "0.002", "1.34178", "0.00003", "0", "", "", "0005", "", "A", "82", "L", "94", "22", "83", "50.0", "92.0", "100.8", "", "", "", "", "99.1"]} +{"pcdb_id": 19112, "brand_name": "Morco", "model_name": "IV", "model_qualifier": "GB30 PROPANE", "winter_efficiency_pct": 90.1, "summer_efficiency_pct": 90.3, "comparative_hot_water_efficiency_pct": 68.7, "output_kw_max": 24.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.0065, "loss_factor_f1_kwh_per_day": 1.71798, "loss_factor_f2_kwh_per_day": 1.65101, "rejected_factor_f3_per_litre": 5e-05, "raw": ["019112", "020099", "0", "2023/Oct/20 15:53", "Ideal Boilers", "Morco", "IV", "GB30 PROPANE", "236486", "2023", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24.2", "24.2", "A", "", "90.1", "90.3", "", "68.7", "", "2", "1", "", "104", "1", "2", "29", "3", "0", "", "", "", "0", "", "", "", "", "2", "7.841", "0.144", "0.0065", "1.71798", "13.663", "0.17", "0.002", "1.65101", "0.00005", "0", "", "", "0005", "", "A", "80", "L", "94", "14", "65", "50.0", "92.0", "100.8", "", "", "", "", "99.1"]} +{"pcdb_id": 19113, "brand_name": "Morco", "model_name": "IV", "model_qualifier": "GB24 NG", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 70.0, "output_kw_max": 24.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0027, "loss_factor_f1_kwh_per_day": 1.43483, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["019113", "020099", "0", "2023/Oct/20 15:04", "Ideal Boilers", "Morco", "IV", "GB24 NG", "236487", "2023", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.3", "24.3", "A", "", "89.0", "87.3", "", "70.0", "", "2", "", "", "104", "1", "2", "44", "3", "0", "", "", "", "0", "", "", "", "", "1", "7.526", "0.12", "0.0027", "1.43483", "", "", "", "", "", "0", "", "", "0005", "", "A", "77", "M", "94", "12", "70", "50.0", "90.0", "98.6", "", "", "", "", "96.9"]} +{"pcdb_id": 19114, "brand_name": "Morco", "model_name": "IV", "model_qualifier": "GB30 NG", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 87.3, "comparative_hot_water_efficiency_pct": 69.5, "output_kw_max": 24.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0027, "loss_factor_f1_kwh_per_day": 1.48359, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["019114", "020099", "0", "2023/Oct/20 15:40", "Ideal Boilers", "Morco", "IV", "GB30 NG", "236488", "2023", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.3", "24.3", "A", "", "89.0", "87.3", "", "69.5", "", "2", "", "", "104", "1", "2", "28", "3", "0", "", "", "", "0", "", "", "", "", "1", "7.576", "0.119", "0.0027", "1.48359", "", "", "", "", "", "0", "", "", "0005", "", "A", "76", "M", "94", "11", "58", "50.0", "90.0", "98.6", "", "", "", "", "96.9"]} +{"pcdb_id": 19115, "brand_name": "Baxi", "model_name": "ASSURE 524 SYSTEM 2", "model_qualifier": "", "winter_efficiency_pct": 89.9, "summer_efficiency_pct": 80.9, "comparative_hot_water_efficiency_pct": 59.1, "output_kw_max": 27.4, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["019115", "020101", "0", "2023/Oct/25 16:32", "Baxi Heating UK Ltd", "Baxi", "ASSURE 524 SYSTEM 2", "", "41-844-06", "2023", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "27.4", "27.4", "A", "", "89.9", "80.9", "", "59.1", "", "2", "1", "", "102", "1", "2", "46", "4", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "94", "8", "68", "40.0", "90.2", "101.2", "", "", "", "", "99.1"]} +{"pcdb_id": 19116, "brand_name": "Baxi", "model_name": "ASSURE 518 SYSTEM 2", "model_qualifier": "", "winter_efficiency_pct": 89.9, "summer_efficiency_pct": 80.9, "comparative_hot_water_efficiency_pct": 59.1, "output_kw_max": 20.7, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["019116", "020101", "0", "2023/Oct/25 16:33", "Baxi Heating UK Ltd", "Baxi", "ASSURE 518 SYSTEM 2", "", "41-844-05", "2023", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "20.7", "20.7", "A", "", "89.9", "80.9", "", "59.1", "", "2", "1", "", "102", "1", "2", "26", "4", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "94", "8", "56", "40.0", "90.2", "101.2", "", "", "", "", "99.1"]} +{"pcdb_id": 19117, "brand_name": "Baxi", "model_name": "ASSURE 515 SYSTEM 2", "model_qualifier": "", "winter_efficiency_pct": 89.9, "summer_efficiency_pct": 80.9, "comparative_hot_water_efficiency_pct": 59.1, "output_kw_max": 17.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["019117", "020101", "0", "2023/Oct/25 16:33", "Baxi Heating UK Ltd", "Baxi", "ASSURE 515 SYSTEM 2", "", "41-844-04", "2023", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "17.2", "17.2", "A", "", "89.9", "80.9", "", "59.1", "", "2", "1", "", "102", "1", "2", "16", "4", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0405", "", "", "", "", "94", "8", "51", "40.0", "90.2", "101.2", "", "", "", "", "99.1"]} +{"pcdb_id": 19118, "brand_name": "Baxi", "model_name": "ASSURE 524 COMBI 2", "model_qualifier": "", "winter_efficiency_pct": 89.9, "summer_efficiency_pct": 88.7, "comparative_hot_water_efficiency_pct": 82.2, "output_kw_max": 22.9, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0029, "loss_factor_f1_kwh_per_day": 0.44307, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["019118", "020101", "0", "2023/Oct/25 16:35", "Baxi Heating UK Ltd", "Baxi", "ASSURE 524 COMBI 2", "", "47-077-59", "2023", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "22.9", "22.9", "A", "", "89.9", "88.7", "", "82.2", "", "2", "1", "", "104", "1", "2", "46", "4", "0", "", "", "", "0", "", "", "", "", "1", "6.548", "0.074", "0.0029", "0.44307", "", "", "", "", "", "0", "", "", "0405", "", "A", "93", "XL", "94", "8", "68", "40.0", "90.2", "101.2", "", "", "", "", "99.1"]} +{"pcdb_id": 19119, "brand_name": "Baxi", "model_name": "ASSURE 530 COMBI 2", "model_qualifier": "", "winter_efficiency_pct": 89.9, "summer_efficiency_pct": 88.6, "comparative_hot_water_efficiency_pct": 83.2, "output_kw_max": 28.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0021, "loss_factor_f1_kwh_per_day": 0.37197, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["019119", "020101", "0", "2023/Oct/25 16:35", "Baxi Heating UK Ltd", "Baxi", "ASSURE 530 COMBI 2", "", "47-077-60", "2023", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "28.6", "28.6", "A", "", "89.9", "88.6", "", "83.2", "", "2", "1", "", "104", "1", "2", "61", "4", "0", "", "", "", "0", "", "", "", "", "1", "6.474", "0.071", "0.0021", "0.37197", "", "", "", "", "", "0", "", "", "0405", "", "A", "93", "XL", "94", "9", "79", "40.0", "90.0", "101.1", "", "", "", "", "99.0"]} +{"pcdb_id": 19120, "brand_name": "Baxi", "model_name": "ASSURE 536 COMBI 2", "model_qualifier": "", "winter_efficiency_pct": 89.8, "summer_efficiency_pct": 88.6, "comparative_hot_water_efficiency_pct": 83.2, "output_kw_max": 28.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0021, "loss_factor_f1_kwh_per_day": 0.37024, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["019120", "020101", "0", "2023/Oct/25 16:35", "Baxi Heating UK Ltd", "Baxi", "ASSURE 536 COMBI 2", "", "47-077-61", "2023", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "28.6", "28.6", "A", "", "89.8", "88.6", "", "83.2", "", "2", "1", "", "104", "1", "2", "71", "4", "0", "", "", "", "0", "", "", "", "", "1", "6.47", "0.071", "0.0021", "0.37024", "", "", "", "", "", "0", "", "", "0405", "", "A", "93", "XL", "94", "9", "85", "40.0", "90.1", "101.0", "", "", "", "", "99.0"]} +{"pcdb_id": 19121, "brand_name": "Viessmann", "model_name": "VITODENS 050-W", "model_qualifier": "B0KA-35", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 84.4, "comparative_hot_water_efficiency_pct": 69.4, "output_kw_max": 29.9, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.004, "loss_factor_f1_kwh_per_day": 1.41177, "loss_factor_f2_kwh_per_day": 1.10061, "rejected_factor_f3_per_litre": 2e-05, "raw": ["019121", "020094", "0", "2023/Nov/15 13:27", "Viessmann Ltd", "Viessmann", "VITODENS 050-W", "B0KA-35", "", "2022", "current", "1", "2", "1", "2", "0", "", "", "2", "3", "2", "29.9", "29.9", "A", "", "88.3", "84.4", "", "69.4", "", "2", "", "", "104", "1", "2", "22.1", "4.1", "0", "", "", "", "0", "", "", "", "", "2", "7.592", "0.207", "0.004", "1.41177", "13.791", "0.233", "0.0017", "1.10061", "0.00002", "0", "", "", "00020005", "", "A", "81", "XL", "93", "14.7", "69", "56.3", "87.1", "97.8", "", "", "", "", "95.8"]} +{"pcdb_id": 19122, "brand_name": "Viessmann", "model_name": "VITODENS 050-W", "model_qualifier": "B0KA-35", "winter_efficiency_pct": 89.5, "summer_efficiency_pct": 87.6, "comparative_hot_water_efficiency_pct": 66.5, "output_kw_max": 30.2, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.0022, "loss_factor_f1_kwh_per_day": 1.91888, "loss_factor_f2_kwh_per_day": 1.68297, "rejected_factor_f3_per_litre": 1e-05, "raw": ["019122", "020094", "0", "2023/Nov/15 13:28", "Viessmann Ltd", "Viessmann", "VITODENS 050-W", "B0KA-35", "", "2022", "current", "2", "2", "1", "2", "0", "", "", "2", "3", "2", "30.2", "30.2", "A", "", "89.5", "87.6", "", "66.5", "", "2", "0", "2", "104", "1", "2", "22.1", "4.1", "0", "", "", "", "0", "", "", "", "", "2", "8.093", "0.204", "0.0022", "1.91888", "14.203", "0.225", "0.001", "1.68297", "0.00001", "0", "", "", "00020005", "", "A", "81", "XL", "93", "14.7", "69", "56.3", "89.6", "97.7", "", "", "", "", "96.2"]} +{"pcdb_id": 19123, "brand_name": "Alpha Innovation", "model_name": "E-Tec 33 HB", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 88.2, "comparative_hot_water_efficiency_pct": 75.8, "output_kw_max": 32.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.006, "loss_factor_f1_kwh_per_day": 0.81076, "loss_factor_f2_kwh_per_day": 0.78634, "rejected_factor_f3_per_litre": 2e-05, "raw": ["019123", "020029", "0", "2023/Nov/15 11:26", "Immergas", "Alpha Innovation", "E-Tec 33 HB", "", "3.033301", "2023", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "4.9", "32", "A", "", "88.4", "88.2", "", "75.8", "", "2", "", "", "104", "1", "2", "12", "2", "0", "", "", "", "0", "", "", "", "", "2", "6.949", "0.115", "0.006", "0.81076", "12.677", "0.124", "0.004", "0.78634", "0.00002", "0", "", "0", "0025", "", "A", "87", "XL", "93", "6", "32", "57.0", "88.2", "97.7", "", "", "", "", "95.9"]} +{"pcdb_id": 19124, "brand_name": "Vokera By Riello", "model_name": "UNICA MAX", "model_qualifier": "30S", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 31.23, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["019124", "020088", "0", "2023/Dec/18 11:47", "Vokera Ltd.", "Vokera By Riello", "UNICA MAX", "30S", "41-364-14", "2021", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "31.23", "31.23", "A", "", "88.7", "79.7", "", "58.2", "", "2", "", "", "102", "1", "2", "49", "3", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "94", "13", "75", "26.0", "87.9", "98.7", "", "", "", "", "96.6"]} +{"pcdb_id": 19125, "brand_name": "Vokera By Riello", "model_name": "UNICA MAX", "model_qualifier": "30C", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 88.2, "comparative_hot_water_efficiency_pct": 77.0, "output_kw_max": 24.43, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.0029, "loss_factor_f1_kwh_per_day": 0.71465, "loss_factor_f2_kwh_per_day": 0.6951, "rejected_factor_f3_per_litre": 3e-05, "raw": ["019125", "020088", "0", "2023/Dec/18 11:06", "Vokera Ltd.", "Vokera By Riello", "UNICA MAX", "30C", "47-364-75", "2022", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.43", "24.43", "A", "", "88.7", "88.2", "", "77.0", "", "2", "", "", "104", "1", "2", "32", "3", "0", "", "", "", "0", "", "", "", "", "2", "6.835", "0.142", "0.0029", "0.71465", "12.377", "0.113", "0.0003", "0.6951", "0.00003", "0", "", "", "0025", "", "A", "85", "XL", "94", "13", "65", "26.0", "88.0", "98.7", "", "", "", "", "96.6"]} +{"pcdb_id": 19126, "brand_name": "Vaillant", "model_name": "ecoTEC plus 610", "model_qualifier": "VU 10CS/1-5 (N-GB)", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 10.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["019126", "020033", "0", "2023/Dec/07 11:40", "Vaillant Group UK Ltd", "Vaillant", "ecoTEC plus 610", "VU 10CS/1-5 (N-GB)", "41-694-45", "2023", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "10", "10", "A", "", "88.2", "79.2", "", "57.8", "", "2", "", "", "102", "1", "2", "17", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "00C5", "", "", "", "", "92", "13", "50", "42.0", "87.5", "97.5", "", "", "", "", "95.6"]} +{"pcdb_id": 19127, "brand_name": "Vaillant", "model_name": "ecoTEC plus 615", "model_qualifier": "VU 15CS/1-5 (N-GB)", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 15.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["019127", "020033", "0", "2023/Dec/07 11:44", "Vaillant Group UK Ltd", "Vaillant", "ecoTEC plus 615", "VU 15CS/1-5 (N-GB)", "41-694-46", "2023", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "15", "15", "A", "", "88.3", "79.3", "", "57.9", "", "2", "", "", "102", "1", "2", "22", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "00C5", "", "", "", "", "93", "13", "53", "42.0", "87.4", "97.8", "", "", "", "", "95.9"]} +{"pcdb_id": 19128, "brand_name": "Vaillant", "model_name": "ecoTEC plus 625", "model_qualifier": "VU 25CS/1-5 (N-GB)", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 25.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["019128", "020033", "0", "2023/Dec/07 11:54", "Vaillant Group UK Ltd", "Vaillant", "ecoTEC plus 625", "VU 25CS/1-5 (N-GB)", "41-694-48", "2023", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "25", "25", "A", "", "88.7", "79.7", "", "58.2", "", "2", "", "", "102", "1", "2", "28", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "00C5", "", "", "", "", "94", "15", "61", "48.0", "88.1", "98.6", "", "", "", "", "96.6"]} +{"pcdb_id": 19129, "brand_name": "Vaillant", "model_name": "ecoTEC plus 630", "model_qualifier": "VU 30CS/1-5 (N-GB)", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 79.6, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 30.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["019129", "020033", "0", "2023/Dec/07 11:59", "Vaillant Group UK Ltd", "Vaillant", "ecoTEC plus 630", "VU 30CS/1-5 (N-GB)", "41-694-49", "2023", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "30", "30", "A", "", "88.6", "79.6", "", "58.1", "", "2", "", "", "102", "1", "2", "36", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "00C5", "", "", "", "", "94", "16", "68", "45.0", "88.0", "98.3", "", "", "", "", "96.3"]} +{"pcdb_id": 19130, "brand_name": "Vaillant", "model_name": "ecoTEC plus 635", "model_qualifier": "VU 35CS/1-5 (N-GB)", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 35.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["019130", "020033", "0", "2023/Dec/07 12:04", "Vaillant Group UK Ltd", "Vaillant", "ecoTEC plus 635", "VU 35CS/1-5 (N-GB)", "41-694-50", "2023", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "35", "35", "A", "", "88.7", "79.7", "", "58.2", "", "2", "", "", "102", "1", "2", "51", "1", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "00C5", "", "", "", "", "94", "16", "70", "52.0", "87.9", "98.6", "", "", "", "", "96.5"]} +{"pcdb_id": 19131, "brand_name": "Vaillant", "model_name": "ecoTEC plus 826", "model_qualifier": "VUW 20/26CS/1-5 (N-GB)", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 81.8, "comparative_hot_water_efficiency_pct": 79.7, "output_kw_max": 20.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.0134, "loss_factor_f1_kwh_per_day": 0.4205, "loss_factor_f2_kwh_per_day": 0.0, "rejected_factor_f3_per_litre": 9e-05, "raw": ["019131", "020033", "0", "2023/Dec/07 12:09", "Vaillant Group UK Ltd", "Vaillant", "ecoTEC plus 826", "VUW 20/26CS/1-5 (N-GB)", "47-044-92", "2023", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "20", "20", "A", "", "88.4", "81.8", "", "79.7", "", "2", "", "", "104", "1", "2", "31", "2", "0", "", "", "", "0", "", "", "", "", "2", "6.604", "0.074", "0.0134", "0.4205", "12.977", "0.088", "0.0044", "0.0", "0.00009", "0", "", "", "00C5", "", "A", "87", "XL", "93", "14", "60", "47.0", "87.6", "98.0", "", "", "", "", "96.0"]} +{"pcdb_id": 19132, "brand_name": "Vaillant", "model_name": "ecoTEC plus 832", "model_qualifier": "VUW 25/32CS/1-5 (N-GB)", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 81.2, "comparative_hot_water_efficiency_pct": 68.9, "output_kw_max": 25.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.0076, "loss_factor_f1_kwh_per_day": 1.4729, "loss_factor_f2_kwh_per_day": 0.8671, "rejected_factor_f3_per_litre": 7e-05, "raw": ["019132", "020033", "0", "2023/Dec/07 12:14", "Vaillant Group UK Ltd", "Vaillant", "ecoTEC plus 832", "VUW 25/32CS/1-5 (N-GB)", "47-044-93", "2023", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "25", "25", "A", "", "88.7", "81.2", "", "68.9", "", "2", "", "", "104", "1", "2", "28", "2", "0", "", "", "", "0", "", "", "", "", "2", "7.649", "0.072", "0.0076", "1.4729", "14.057", "0.085", "0.0009", "0.8671", "0.00007", "0", "", "", "00C5", "", "A", "84", "XL", "94", "15", "61", "49.0", "88.1", "98.6", "", "", "", "", "96.6"]} +{"pcdb_id": 19133, "brand_name": "Vaillant", "model_name": "ecoTEC plus 836", "model_qualifier": "VUW 30/36CS/1-5 (N-GB)", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 80.7, "comparative_hot_water_efficiency_pct": 78.2, "output_kw_max": 30.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.0102, "loss_factor_f1_kwh_per_day": 0.57567, "loss_factor_f2_kwh_per_day": 0.0069, "rejected_factor_f3_per_litre": 9e-05, "raw": ["019133", "020033", "0", "2023/Dec/07 12:18", "Vaillant Group UK Ltd", "Vaillant", "ecoTEC plus 836", "VUW 30/36CS/1-5 (N-GB)", "47-044-94", "2023", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "30", "30", "A", "", "88.6", "80.7", "", "78.2", "", "2", "", "", "104", "1", "2", "36", "2", "0", "", "", "", "0", "", "", "", "", "2", "6.735", "0.08", "0.0102", "0.57567", "13.171", "0.094", "0.0012", "0.0069", "0.00009", "0", "", "", "00C5", "", "A", "87", "XL", "94", "16", "68", "49.0", "88.0", "98.3", "", "", "", "", "96.3"]} +{"pcdb_id": 19134, "brand_name": "Vaillant", "model_name": "ecoTEC plus 840", "model_qualifier": "VUW 30/40CS/1-5 (N-GB)", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 78.0, "comparative_hot_water_efficiency_pct": 79.3, "output_kw_max": 30.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.0057, "loss_factor_f1_kwh_per_day": 0.50928, "loss_factor_f2_kwh_per_day": 0.0, "rejected_factor_f3_per_litre": 5e-05, "raw": ["019134", "020033", "0", "2023/Dec/07 12:21", "Vaillant Group UK Ltd", "Vaillant", "ecoTEC plus 840", "VUW 30/40CS/1-5 (N-GB)", "47-044-95", "2023", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "30", "30", "A", "", "88.6", "78.0", "", "79.3", "", "2", "", "", "104", "1", "2", "39", "1", "0", "", "", "", "0", "", "", "", "", "2", "6.643", "0.072", "0.0057", "0.50928", "13.327", "0.127", "0.0009", "0.0", "0.00005", "0", "", "", "00C5", "", "A", "89", "XL", "94", "15", "61", "56.0", "87.8", "98.4", "", "", "", "", "96.4"]} +{"pcdb_id": 19135, "brand_name": "Vaillant", "model_name": "ecoTEC plus 620", "model_qualifier": "VU 20CS/1-5 (N-GB)", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 20.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["019135", "020033", "0", "2023/Dec/07 11:50", "Vaillant Group UK Ltd", "Vaillant", "ecoTEC plus 620", "VU 20CS/1-5 (N-GB)", "41-694-47", "2023", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "20", "20", "A", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "31", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "00C5", "", "", "", "", "93", "14", "60", "47.0", "87.6", "98.0", "", "", "", "", "96.0"]} +{"pcdb_id": 19136, "brand_name": "Navien", "model_name": "NCB300", "model_qualifier": "NCB300-28K", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 88.2, "comparative_hot_water_efficiency_pct": 70.4, "output_kw_max": 24.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.0245, "loss_factor_f1_kwh_per_day": 1.21005, "loss_factor_f2_kwh_per_day": 1.18378, "rejected_factor_f3_per_litre": 0.00023, "raw": ["019136", "020178", "0", "2024/Jan/26 09:28", "Navien UK", "Navien", "NCB300", "NCB300-28K", "", "2022", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "A", "", "88.1", "88.2", "", "70.4", "", "2", "", "", "104", "1", "2", "39", "3", "0", "", "", "", "0", "", "", "", "", "2", "7.476", "0.125", "0.0245", "1.21005", "13.146", "0.142", "0.002", "1.18378", "0.00023", "0", "", "", "0005", "", "A", "84", "XL", "93", "17", "78", "78.0", "88.2", "96.9", "", "", "", "", "95.3"]} +{"pcdb_id": 19137, "brand_name": "Vokera By Riello", "model_name": "VIBE MAX", "model_qualifier": "26C", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 87.6, "comparative_hot_water_efficiency_pct": 77.2, "output_kw_max": 19.38, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.003, "loss_factor_f1_kwh_per_day": 0.68563, "loss_factor_f2_kwh_per_day": 0.63873, "rejected_factor_f3_per_litre": 2e-05, "raw": ["019137", "020088", "0", "2024/Feb/02 10:25", "Vokera Ltd.", "Vokera By Riello", "VIBE MAX", "26C", "47-364-69", "2022", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "19.38", "19.38", "A", "", "88.5", "87.6", "", "77.2", "", "2", "", "", "104", "1", "2", "32", "3", "0", "", "", "", "0", "", "", "", "", "2", "6.824", "0.102", "0.003", "0.68563", "12.795", "0.107", "0.0011", "0.63873", "0.00002", "0", "", "", "0025", "", "A", "84", "XL", "93", "12", "63", "30.0", "87.3", "98.3", "", "", "", "", "96.2"]} +{"pcdb_id": 19138, "brand_name": "Vokera By Riello", "model_name": "VIBE MAX", "model_qualifier": "30C", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 85.1, "comparative_hot_water_efficiency_pct": 77.5, "output_kw_max": 24.38, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.001, "loss_factor_f1_kwh_per_day": 0.6857, "loss_factor_f2_kwh_per_day": 0.44078, "rejected_factor_f3_per_litre": -1e-05, "raw": ["019138", "020088", "0", "2024/Feb/02 10:38", "Vokera Ltd.", "Vokera By Riello", "VIBE MAX", "30C", "47-364-70", "2022", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.38", "24.38", "A", "", "88.5", "85.1", "", "77.5", "", "2", "", "", "104", "1", "2", "38", "3", "0", "", "", "", "0", "", "", "", "", "2", "6.798", "0.102", "0.001", "0.6857", "12.963", "0.118", "0.0016", "0.44078", "-0.00001", "0", "", "", "0025", "", "A", "84", "XL", "93", "12", "66", "32.0", "87.8", "98.0", "", "", "", "", "96.1"]} +{"pcdb_id": 19139, "brand_name": "Vokera By Riello", "model_name": "VIBE MAX", "model_qualifier": "20S", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 19.38, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["019139", "020088", "0", "2024/Feb/02 11:05", "Vokera Ltd.", "Vokera By Riello", "VIBE MAX", "20S", "41-364-19", "2022", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "19.38", "19.38", "A", "", "88.5", "79.5", "", "58.1", "", "2", "", "", "102", "1", "2", "32", "3", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "93", "12", "63", "30.0", "87.3", "98.3", "", "", "", "", "96.2"]} +{"pcdb_id": 19140, "brand_name": "Vokera By Riello", "model_name": "VIBE MAX", "model_qualifier": "25S", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 24.38, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["019140", "020088", "0", "2024/Feb/02 11:06", "Vokera Ltd.", "Vokera By Riello", "VIBE MAX", "25S", "41-364-20", "2022", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24.38", "24.38", "A", "", "88.5", "79.5", "", "58.0", "", "2", "", "", "102", "1", "2", "38", "3", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "93", "12", "66", "32.0", "87.8", "98.0", "", "", "", "", "96.1"]} +{"pcdb_id": 19141, "brand_name": "Vokera By Riello", "model_name": "EXCEL-i", "model_qualifier": "25C", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 87.6, "comparative_hot_water_efficiency_pct": 77.2, "output_kw_max": 19.38, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.003, "loss_factor_f1_kwh_per_day": 0.68563, "loss_factor_f2_kwh_per_day": 0.63873, "rejected_factor_f3_per_litre": 2e-05, "raw": ["019141", "020088", "0", "2024/Feb/02 11:15", "Vokera Ltd.", "Vokera By Riello", "EXCEL-i", "25C", "47-364-65", "2021", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "19.38", "19.38", "A", "", "88.5", "87.6", "", "77.2", "", "2", "", "", "104", "1", "2", "32", "3", "0", "", "", "", "0", "", "", "", "", "2", "6.824", "0.102", "0.003", "0.68563", "12.795", "0.107", "0.0011", "0.63873", "0.00002", "0", "", "", "0025", "", "A", "84", "XL", "93", "12", "63", "30.0", "87.3", "98.3", "", "", "", "", "96.2"]} +{"pcdb_id": 19142, "brand_name": "Vokera By Riello", "model_name": "EXCEL-i", "model_qualifier": "30C", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 85.1, "comparative_hot_water_efficiency_pct": 77.5, "output_kw_max": 24.38, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.001, "loss_factor_f1_kwh_per_day": 0.6857, "loss_factor_f2_kwh_per_day": 0.44078, "rejected_factor_f3_per_litre": -1e-05, "raw": ["019142", "020088", "0", "2024/Feb/02 11:26", "Vokera Ltd.", "Vokera By Riello", "EXCEL-i", "30C", "47-364-66", "2022", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.38", "24.38", "A", "", "88.5", "85.1", "", "77.5", "", "2", "", "", "104", "1", "2", "38", "3", "0", "", "", "", "0", "", "", "", "", "2", "6.798", "0.102", "0.001", "0.6857", "12.963", "0.118", "0.0016", "0.44078", "-0.00001", "0", "", "", "0025", "", "A", "84", "XL", "93", "12", "66", "32.0", "87.8", "98.0", "", "", "", "", "96.1"]} +{"pcdb_id": 19143, "brand_name": "Vokera By Riello", "model_name": "EASI-HEAT i", "model_qualifier": "20S", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.1, "output_kw_max": 19.38, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["019143", "020088", "0", "2024/Feb/02 11:35", "Vokera Ltd.", "Vokera By Riello", "EASI-HEAT i", "20S", "47-364-17", "2022", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "19.38", "19.38", "A", "", "88.5", "79.5", "", "58.1", "", "2", "", "", "102", "1", "2", "32", "3", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "93", "12", "63", "30.0", "87.3", "98.3", "", "", "", "", "96.2"]} +{"pcdb_id": 19144, "brand_name": "Navien", "model_name": "NCB300", "model_qualifier": "NCB300-28K", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 90.3, "comparative_hot_water_efficiency_pct": 73.3, "output_kw_max": 24.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.0065, "loss_factor_f1_kwh_per_day": 1.18048, "loss_factor_f2_kwh_per_day": 1.17539, "rejected_factor_f3_per_litre": 4e-05, "raw": ["019144", "020178", "0", "2024/Jan/26 09:37", "Navien UK", "Navien", "NCB300", "NCB300-28K", "", "2022", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "A", "", "88.7", "90.3", "", "73.3", "", "2", "0", "2", "104", "1", "2", "39", "3", "0", "", "", "", "0", "", "", "", "", "2", "7.346", "0.111", "0.0065", "1.18048", "13.261", "0.135", "0.0025", "1.17539", "0.00004", "0", "", "", "0005", "", "A", "84", "XL", "93", "17", "78", "78.0", "89.8", "95.7", "", "", "", "", "94.6"]} +{"pcdb_id": 19145, "brand_name": "Navien", "model_name": "NCB300", "model_qualifier": "NCB300-37K", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 87.2, "comparative_hot_water_efficiency_pct": 71.5, "output_kw_max": 26.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.006, "loss_factor_f1_kwh_per_day": 1.21901, "loss_factor_f2_kwh_per_day": 1.10586, "rejected_factor_f3_per_litre": 4e-05, "raw": ["019145", "020178", "0", "2024/Jan/26 09:51", "Navien UK", "Navien", "NCB300", "NCB300-37K", "", "2022", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "26", "26", "A", "", "88.3", "87.2", "", "71.5", "", "2", "", "", "104", "1", "2", "34", "3", "0", "", "", "", "0", "", "", "", "", "2", "7.363", "0.116", "0.006", "1.21901", "13.358", "0.134", "0.0025", "1.10586", "0.00004", "0", "", "", "0005", "", "A", "84", "XL", "93", "16", "72", "78.0", "88.6", "97.4", "", "", "", "", "95.7"]} +{"pcdb_id": 19146, "brand_name": "Navien", "model_name": "NCB300", "model_qualifier": "NCB300-41K", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 88.2, "comparative_hot_water_efficiency_pct": 70.0, "output_kw_max": 26.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.012, "loss_factor_f1_kwh_per_day": 1.34303, "loss_factor_f2_kwh_per_day": 1.30673, "rejected_factor_f3_per_litre": 0.00011, "raw": ["019146", "020178", "0", "2024/Jan/26 10:03", "Navien UK", "Navien", "NCB300", "NCB300-41K", "", "2022", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "26", "26", "A", "", "88.3", "88.2", "", "70.0", "", "2", "", "", "104", "1", "2", "34", "3", "0", "", "", "", "0", "", "", "", "", "2", "7.528", "0.123", "0.012", "1.34303", "13.168", "0.138", "0.0015", "1.30673", "0.00011", "0", "", "", "0005", "", "A", "83", "XL", "93", "16", "72", "78.0", "88.6", "97.4", "", "", "", "", "95.7"]} +{"pcdb_id": 19147, "brand_name": "Navien", "model_name": "NCB300", "model_qualifier": "NCB300-37K", "winter_efficiency_pct": 89.8, "summer_efficiency_pct": 90.3, "comparative_hot_water_efficiency_pct": 72.1, "output_kw_max": 26.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.006, "loss_factor_f1_kwh_per_day": 1.3349, "loss_factor_f2_kwh_per_day": 1.29553, "rejected_factor_f3_per_litre": 4e-05, "raw": ["019147", "020178", "0", "2024/Jan/26 10:12", "Navien UK", "Navien", "NCB300", "NCB300-37K", "", "2022", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "26", "26", "A", "", "89.8", "90.3", "", "72.1", "", "2", "0", "2", "104", "1", "2", "34", "3", "0", "", "", "", "0", "", "", "", "", "2", "7.468", "0.123", "0.006", "1.3349", "13.329", "0.139", "0.002", "1.29553", "0.00004", "0", "", "", "0005", "", "A", "84", "XL", "93", "16", "72", "78.0", "91.1", "97.8", "", "", "", "", "96.5"]} +{"pcdb_id": 19148, "brand_name": "Navien", "model_name": "NCB300", "model_qualifier": "NCB300-41K", "winter_efficiency_pct": 89.8, "summer_efficiency_pct": 90.3, "comparative_hot_water_efficiency_pct": 73.3, "output_kw_max": 26.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.0055, "loss_factor_f1_kwh_per_day": 1.21416, "loss_factor_f2_kwh_per_day": 1.17547, "rejected_factor_f3_per_litre": 3e-05, "raw": ["019148", "020178", "0", "2024/Jan/26 10:34", "Navien UK", "Navien", "NCB300", "NCB300-41K", "", "2022", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "26", "26", "A", "", "89.8", "90.3", "", "73.3", "", "2", "0", "2", "104", "1", "2", "34", "3", "0", "", "", "", "0", "", "", "", "", "2", "7.34", "0.11", "0.0055", "1.21416", "13.254", "0.127", "0.0025", "1.17547", "0.00003", "0", "", "", "0005", "", "A", "83", "XL", "93", "16", "72", "78.0", "91.1", "97.8", "", "", "", "", "96.5"]} +{"pcdb_id": 19149, "brand_name": "Navien", "model_name": "NCB700", "model_qualifier": "NCB700-2S+/42K", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 88.2, "comparative_hot_water_efficiency_pct": 75.5, "output_kw_max": 34.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.005, "loss_factor_f1_kwh_per_day": 0.84296, "loss_factor_f2_kwh_per_day": 0.81617, "rejected_factor_f3_per_litre": 4e-05, "raw": ["019149", "020178", "0", "2024/Jan/26 10:54", "Navien UK", "Navien", "NCB700", "NCB700-2S+/42K", "", "2022", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "34", "34", "A", "", "88.7", "88.2", "", "75.5", "", "2", "", "", "104", "1", "2", "51", "3", "0", "", "", "", "0", "", "", "", "", "2", "6.974", "0.124", "0.005", "0.84296", "12.614", "0.138", "0.0015", "0.81617", "0.00004", "0", "", "", "0005", "", "A", "86", "XXL", "94", "25", "102", "89.0", "88.3", "98.6", "", "", "", "", "96.6"]} +{"pcdb_id": 19150, "brand_name": "Navien", "model_name": "NCB700", "model_qualifier": "NCB700-2S+/42k", "winter_efficiency_pct": 90.2, "summer_efficiency_pct": 90.3, "comparative_hot_water_efficiency_pct": 75.4, "output_kw_max": 34.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.005, "loss_factor_f1_kwh_per_day": 1.01959, "loss_factor_f2_kwh_per_day": 0.9843, "rejected_factor_f3_per_litre": 3e-05, "raw": ["019150", "020178", "0", "2024/Jan/26 11:05", "Navien UK", "Navien", "NCB700", "NCB700-2S+/42k", "", "2022", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "34", "34", "A", "", "90.2", "90.3", "", "75.4", "", "2", "0", "2", "104", "1", "2", "51", "3", "0", "", "", "", "0", "", "", "", "", "2", "7.138", "0.135", "0.005", "1.01959", "12.989", "0.152", "0.0025", "0.9843", "0.00003", "0", "", "", "0005", "", "A", "86", "XXL", "94", "25", "102", "89.0", "91.0", "98.9", "", "", "", "", "97.4"]} +{"pcdb_id": 19151, "brand_name": "Navien", "model_name": "NCB700", "model_qualifier": "NCB700-3S/54K", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 88.2, "comparative_hot_water_efficiency_pct": 74.4, "output_kw_max": 34.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.0045, "loss_factor_f1_kwh_per_day": 0.9607, "loss_factor_f2_kwh_per_day": 0.91503, "rejected_factor_f3_per_litre": 3e-05, "raw": ["019151", "020178", "0", "2024/Jan/26 11:16", "Navien UK", "Navien", "NCB700", "NCB700-3S/54K", "", "2022", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "34", "34", "A", "", "89.1", "88.2", "", "74.4", "", "2", "", "", "104", "1", "2", "43", "3", "0", "", "", "", "0", "", "", "", "", "2", "7.074", "0.131", "0.0045", "0.9607", "12.75", "0.148", "0.002", "0.91503", "0.00003", "0", "", "", "0005", "", "A", "86", "XXL", "94", "20", "86", "80.0", "89.0", "99.1", "", "", "", "", "97.2"]} +{"pcdb_id": 19152, "brand_name": "Navien", "model_name": "NCB700", "model_qualifier": "NCB700-3S/54K", "winter_efficiency_pct": 90.2, "summer_efficiency_pct": 90.3, "comparative_hot_water_efficiency_pct": 71.5, "output_kw_max": 34.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.012, "loss_factor_f1_kwh_per_day": 1.34795, "loss_factor_f2_kwh_per_day": 1.31812, "rejected_factor_f3_per_litre": 0.00011, "raw": ["019152", "020178", "0", "2024/Jan/26 11:26", "Navien UK", "Navien", "NCB700", "NCB700-3S/54K", "", "2022", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "34", "34", "A", "", "90.2", "90.3", "", "71.5", "", "2", "0", "2", "104", "1", "2", "43", "3", "0", "", "", "", "0", "", "", "", "", "2", "7.528", "0.123", "0.012", "1.34795", "13.168", "0.138", "0.0015", "1.31812", "0.00011", "0", "", "", "0005", "", "A", "86", "XXL", "94", "20", "86", "80.0", "90.7", "99.2", "", "", "", "", "97.6"]} +{"pcdb_id": 19153, "brand_name": "Navien", "model_name": "NCB500", "model_qualifier": "NCB500-2S/37K", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 88.2, "comparative_hot_water_efficiency_pct": 69.9, "output_kw_max": 26.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.005, "loss_factor_f1_kwh_per_day": 1.38491, "loss_factor_f2_kwh_per_day": 1.3486, "rejected_factor_f3_per_litre": 3e-05, "raw": ["019153", "020178", "0", "2024/Jan/26 11:41", "Navien UK", "Navien", "NCB500", "NCB500-2S/37K", "", "2022", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "26", "26", "A", "", "88.3", "88.2", "", "69.9", "", "2", "", "", "104", "1", "2", "34", "3", "0", "", "", "", "0", "", "", "", "", "2", "7.529", "0.161", "0.005", "1.38491", "13.408", "0.144", "0.002", "1.3486", "0.00003", "0", "", "", "0005", "", "A", "83", "XL", "93", "16", "72", "78.0", "88.6", "97.4", "", "", "", "", "95.7"]} +{"pcdb_id": 19154, "brand_name": "Navien", "model_name": "NCB500", "model_qualifier": "NCB500-2S/37K", "winter_efficiency_pct": 89.8, "summer_efficiency_pct": 88.5, "comparative_hot_water_efficiency_pct": 71.3, "output_kw_max": 26.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.0025, "loss_factor_f1_kwh_per_day": 1.43748, "loss_factor_f2_kwh_per_day": 1.25691, "rejected_factor_f3_per_litre": 1e-05, "raw": ["019154", "020178", "0", "2024/Jan/26 11:51", "Navien UK", "Navien", "NCB500", "NCB500-2S/37K", "", "2022", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "26", "26", "A", "", "89.8", "88.5", "", "71.3", "", "2", "0", "2", "104", "1", "2", "34", "3", "0", "", "", "", "0", "", "", "", "", "2", "7.553", "0.127", "0.0025", "1.43748", "13.599", "0.142", "0.0015", "1.25691", "0.00001", "0", "", "", "0005", "", "A", "83", "XL", "93", "16", "72", "78.0", "91.1", "97.8", "", "", "", "", "96.5"]} +{"pcdb_id": 19155, "brand_name": "Navien", "model_name": "NCB500", "model_qualifier": "NCB500-2S+/41K", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 87.4, "comparative_hot_water_efficiency_pct": 69.7, "output_kw_max": 26.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.002, "loss_factor_f1_kwh_per_day": 1.42558, "loss_factor_f2_kwh_per_day": 1.32039, "rejected_factor_f3_per_litre": 1e-05, "raw": ["019155", "020178", "0", "2024/Jan/26 12:00", "Navien UK", "Navien", "NCB500", "NCB500-2S+/41K", "", "2022", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "26", "26", "A", "", "88.3", "87.4", "", "69.7", "", "2", "", "", "104", "1", "2", "34", "3", "0", "", "", "", "0", "", "", "", "", "2", "7.553", "0.127", "0.002", "1.42558", "13.551", "0.141", "0.0015", "1.32039", "0.00001", "0", "", "", "0005", "", "A", "83", "XL", "93", "16", "72", "78.0", "88.6", "97.4", "", "", "", "", "95.7"]} +{"pcdb_id": 19156, "brand_name": "Navien", "model_name": "NCB500", "model_qualifier": "NCB500-2S+/41K", "winter_efficiency_pct": 89.8, "summer_efficiency_pct": 88.7, "comparative_hot_water_efficiency_pct": 70.3, "output_kw_max": 26.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.002, "loss_factor_f1_kwh_per_day": 1.54088, "loss_factor_f2_kwh_per_day": 1.36976, "rejected_factor_f3_per_litre": 1e-05, "raw": ["019156", "020178", "0", "2024/Jan/26 12:10", "Navien UK", "Navien", "NCB500", "NCB500-2S+/41K", "", "2022", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "26", "26", "A", "", "89.8", "88.7", "", "70.3", "", "2", "0", "2", "104", "1", "2", "34", "3", "0", "", "", "", "0", "", "", "", "", "2", "7.657", "0.122", "0.002", "1.54088", "13.69", "0.141", "0.001", "1.36976", "0.00001", "0", "", "", "0005", "", "A", "83", "XL", "93", "16", "72", "78.0", "91.1", "97.8", "", "", "", "", "96.5"]} +{"pcdb_id": 19157, "brand_name": "Vokera By Riello", "model_name": "EASI-HEAT i", "model_qualifier": "25C", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 87.6, "comparative_hot_water_efficiency_pct": 77.2, "output_kw_max": 19.38, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.003, "loss_factor_f1_kwh_per_day": 0.68563, "loss_factor_f2_kwh_per_day": 0.63873, "rejected_factor_f3_per_litre": 2e-05, "raw": ["019157", "020088", "0", "2024/Feb/02 11:47", "Vokera Ltd.", "Vokera By Riello", "EASI-HEAT i", "25C", "47-364-71", "2022", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "19.38", "19.38", "A", "", "88.5", "87.6", "", "77.2", "", "2", "", "", "104", "1", "2", "32", "3", "0", "", "", "", "0", "", "", "", "", "2", "6.824", "0.102", "0.003", "0.68563", "12.795", "0.107", "0.0011", "0.63873", "0.00002", "0", "", "", "0025", "", "A", "84", "XL", "93", "12", "63", "30.0", "87.3", "98.3", "", "", "", "", "96.2"]} +{"pcdb_id": 19158, "brand_name": "Vokera By Riello", "model_name": "EASI-HEAT i", "model_qualifier": "29C", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 85.1, "comparative_hot_water_efficiency_pct": 77.5, "output_kw_max": 24.38, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.001, "loss_factor_f1_kwh_per_day": 0.6857, "loss_factor_f2_kwh_per_day": 0.44078, "rejected_factor_f3_per_litre": -1e-05, "raw": ["019158", "020088", "0", "2024/Feb/02 11:58", "Vokera Ltd.", "Vokera By Riello", "EASI-HEAT i", "29C", "47-364-72", "2022", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24.38", "24.38", "A", "", "88.5", "85.1", "", "77.5", "", "2", "", "", "104", "1", "2", "38", "3", "0", "", "", "", "0", "", "", "", "", "2", "6.798", "0.102", "0.001", "0.6857", "12.963", "0.118", "0.0016", "0.44078", "-0.00001", "0", "", "", "0025", "", "A", "84", "XL", "93", "12", "66", "32.0", "87.8", "98.0", "", "", "", "", "96.1"]} +{"pcdb_id": 19159, "brand_name": "Vokera By Riello", "model_name": "EASI-HEAT i", "model_qualifier": "25S", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.5, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 24.38, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["019159", "020088", "0", "2024/Feb/02 12:08", "Vokera Ltd.", "Vokera By Riello", "EASI-HEAT i", "25S", "47-364-18", "2022", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24.38", "24.38", "A", "", "88.5", "79.5", "", "58.0", "", "2", "", "", "102", "1", "2", "38", "3", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0025", "", "", "", "", "93", "12", "66", "32.0", "87.8", "98.0", "", "", "", "", "96.1"]} +{"pcdb_id": 19160, "brand_name": "Navien", "model_name": "NCB500", "model_qualifier": "NCB500-1S+/32K", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 88.2, "comparative_hot_water_efficiency_pct": 70.2, "output_kw_max": 26.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.003, "loss_factor_f1_kwh_per_day": 1.36767, "loss_factor_f2_kwh_per_day": 1.33151, "rejected_factor_f3_per_litre": 2e-05, "raw": ["019160", "020178", "0", "2024/Jan/26 12:23", "Navien UK", "Navien", "NCB500", "NCB500-1S+/32K", "", "2022", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "26", "26", "A", "", "88.3", "88.2", "", "70.2", "", "2", "", "", "104", "1", "2", "34", "3", "0", "", "", "", "0", "", "", "", "", "2", "7.499", "0.119", "0.003", "1.36767", "13.389", "0.135", "0.001", "1.33151", "0.00002", "0", "", "", "0005", "", "A", "85", "XL", "93", "16", "72", "78.0", "88.6", "97.4", "", "", "", "", "95.7"]} +{"pcdb_id": 19161, "brand_name": "Navien", "model_name": "NCB500", "model_qualifier": "NCB500-1S+/32K", "winter_efficiency_pct": 89.8, "summer_efficiency_pct": 90.0, "comparative_hot_water_efficiency_pct": 71.6, "output_kw_max": 26.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.003, "loss_factor_f1_kwh_per_day": 1.40171, "loss_factor_f2_kwh_per_day": 1.33627, "rejected_factor_f3_per_litre": 2e-05, "raw": ["019161", "020178", "0", "2024/Jan/26 12:36", "Navien UK", "Navien", "NCB500", "NCB500-1S+/32K", "", "2022", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "26", "26", "A", "", "89.8", "90.0", "", "71.6", "", "2", "0", "2", "104", "1", "2", "34", "3", "0", "", "", "", "0", "", "", "", "", "2", "7.519", "0.118", "0.003", "1.40171", "13.466", "0.136", "0.0015", "1.33627", "0.00002", "0", "", "", "0005", "", "A", "85", "XL", "93", "16", "72", "78.0", "91.1", "97.8", "", "", "", "", "96.5"]} +{"pcdb_id": 19162, "brand_name": "Vaillant", "model_name": "ecoTEC plus 940", "model_qualifier": "VUI 30/40CS/1-5 (N-GB)", "winter_efficiency_pct": 88.6, "summer_efficiency_pct": 78.5, "comparative_hot_water_efficiency_pct": 72.7, "output_kw_max": 30.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.002, "loss_factor_f1_kwh_per_day": 1.1099, "loss_factor_f2_kwh_per_day": 0.33326, "rejected_factor_f3_per_litre": 2e-05, "raw": ["019162", "020033", "0", "2024/May/22 10:02", "Vaillant Group UK Ltd", "Vaillant", "ecoTEC plus 940", "VUI 30/40CS/1-5 (N-GB)", "47-044-96", "2023", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "30", "30", "A", "", "88.6", "78.5", "", "72.7", "", "2", "", "", "104", "1", "2", "39", "1", "0", "", "", "", "0", "", "", "", "", "2", "7.245", "0.153", "0.002", "1.1099", "13.899", "0.182", "0.0002", "0.33326", "0.00002", "0", "", "", "00C5", "", "A", "86", "XL", "94", "15", "61", "55.0", "87.8", "98.4", "", "", "", "", "96.4"]} +{"pcdb_id": 19163, "brand_name": "Ariston", "model_name": "ALTEAS ONE+ NET 35", "model_qualifier": "3302395", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 62.6, "output_kw_max": 30.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["019163", "020102", "0", "2024/Jul/05 10:01", "Ariston S.p.A", "Ariston", "ALTEAS ONE+ NET 35", "3302395", "47-116-98", "2023", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "30.3", "30.3", "A", "", "88.7", "80.1", "", "62.6", "", "2", "", "", "104", "1", "2", "33", "5", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "", "", "0805", "", "A", "86", "XXL", "94", "6", "62", "46.0", "88.4", "98.5", "", "", "", "", "96.6"]} +{"pcdb_id": 19164, "brand_name": "Ariston", "model_name": "GENUS ONE+ WIFI 24", "model_qualifier": "3302396", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 62.6, "output_kw_max": 21.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["019164", "020102", "0", "2024/Jul/05 10:02", "Ariston S.p.A", "Ariston", "GENUS ONE+ WIFI 24", "3302396", "47-116-99", "2023", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "21.5", "21.5", "A", "", "88.8", "80.2", "", "62.6", "", "2", "", "", "104", "1", "2", "21", "5", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "", "", "0805", "", "A", "86", "XL", "94", "7", "57", "40.0", "88.5", "98.7", "", "", "", "", "96.7"]} +{"pcdb_id": 19165, "brand_name": "Ariston", "model_name": "GENUS ONE+ WIFI 30", "model_qualifier": "3302397", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 62.6, "output_kw_max": 27.5, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["019165", "020102", "0", "2024/Jul/05 10:02", "Ariston S.p.A", "Ariston", "GENUS ONE+ WIFI 30", "3302397", "47-888-01", "2023", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "27.5", "27.5", "A", "", "88.8", "80.2", "", "62.6", "", "2", "", "", "104", "1", "2", "29", "5", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "", "", "0805", "", "A", "85", "XL", "94", "7", "62", "45.0", "88.8", "98.5", "", "", "", "", "96.6"]} +{"pcdb_id": 19166, "brand_name": "Ariston", "model_name": "GENUS ONE+ WIFI 35", "model_qualifier": "3302398", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 80.1, "comparative_hot_water_efficiency_pct": 62.6, "output_kw_max": 30.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["019166", "020102", "0", "2024/Jul/05 10:03", "Ariston S.p.A", "Ariston", "GENUS ONE+ WIFI 35", "3302398", "47-888-02", "2023", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "30.3", "30.3", "A", "", "88.7", "80.1", "", "62.6", "", "2", "", "", "104", "1", "2", "33", "5", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "", "", "0805", "", "A", "86", "XXL", "94", "6", "62", "46.0", "88.4", "98.5", "", "", "", "", "96.6"]} +{"pcdb_id": 19167, "brand_name": "Baxi", "model_name": "PLATINUM COMPACT 25 COMBI", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 86.7, "comparative_hot_water_efficiency_pct": 80.2, "output_kw_max": 20.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0005, "loss_factor_f1_kwh_per_day": 0.46696, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["019167", "020101", "0", "2024/Oct/16 16:24", "Baxi Heating UK Ltd", "Baxi", "PLATINUM COMPACT 25 COMBI", "", "47-077-71", "2023", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "20", "20", "A", "", "88.4", "86.7", "", "80.2", "", "2", "", "", "104", "1", "2", "28", "3", "0", "", "", "", "0", "", "", "", "", "1", "6.563", "0.102", "0.0005", "0.46696", "", "", "", "", "", "0", "", "", "0405", "", "A", "90", "XL", "93", "15", "67", "40.0", "88.0", "97.8", "", "", "", "", "95.9"]} +{"pcdb_id": 19168, "brand_name": "Baxi", "model_name": "PLATINUM COMPACT 30 COMBI", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 86.7, "comparative_hot_water_efficiency_pct": 79.3, "output_kw_max": 20.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.001, "loss_factor_f1_kwh_per_day": 0.53909, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["019168", "020101", "0", "2024/Oct/16 16:30", "Baxi Heating UK Ltd", "Baxi", "PLATINUM COMPACT 30 COMBI", "", "47-077-72", "2023", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "20", "20", "A", "", "88.4", "86.7", "", "79.3", "", "2", "", "", "104", "1", "2", "38", "3", "0", "", "", "", "0", "", "", "", "", "1", "6.641", "0.105", "0.001", "0.53909", "", "", "", "", "", "0", "", "", "0405", "", "A", "89", "XL", "93", "15", "73", "40.0", "88.0", "97.8", "", "", "", "", "95.9"]} +{"pcdb_id": 19169, "brand_name": "Baxi", "model_name": "PLATINUM COMPACT 36 COMBI", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 86.7, "comparative_hot_water_efficiency_pct": 81.4, "output_kw_max": 25.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0015, "loss_factor_f1_kwh_per_day": 0.37374, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["019169", "020101", "0", "2024/Oct/16 16:34", "Baxi Heating UK Ltd", "Baxi", "PLATINUM COMPACT 36 COMBI", "", "47-077-73", "2023", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "25", "25", "A", "", "88.4", "86.7", "", "81.4", "", "2", "", "", "104", "1", "2", "72", "3", "0", "", "", "", "0", "", "", "", "", "1", "6.47", "0.102", "0.0015", "0.37374", "", "", "", "", "", "0", "", "", "0405", "", "A", "89", "XL", "93", "15", "92", "40.0", "88.1", "97.8", "", "", "", "", "96.0"]} +{"pcdb_id": 19170, "brand_name": "Baxi", "model_name": "424 COMBI 2.1", "model_qualifier": "", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 86.8, "comparative_hot_water_efficiency_pct": 80.4, "output_kw_max": 20.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0029, "loss_factor_f1_kwh_per_day": 0.44307, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["019170", "020101", "0", "2024/Oct/16 16:39", "Baxi Heating UK Ltd", "Baxi", "424 COMBI 2.1", "", "47-077-74", "2024", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "20", "20", "A", "", "88.9", "86.8", "", "80.4", "", "2", "", "", "104", "1", "2", "46", "4", "0", "", "", "", "0", "", "", "", "", "1", "6.548", "0.074", "0.0029", "0.44307", "", "", "", "", "", "0", "", "", "0405", "", "A", "93", "XL", "94", "8", "68", "40.0", "88.2", "99.0", "", "", "", "", "97.0"]} +{"pcdb_id": 19171, "brand_name": "Baxi", "model_name": "424 COMBI 2.1 LPG", "model_qualifier": "", "winter_efficiency_pct": 89.9, "summer_efficiency_pct": 88.7, "comparative_hot_water_efficiency_pct": 82.2, "output_kw_max": 20.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0029, "loss_factor_f1_kwh_per_day": 0.44307, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["019171", "020101", "0", "2024/Oct/16 16:44", "Baxi Heating UK Ltd", "Baxi", "424 COMBI 2.1 LPG", "", "47-077-74", "2024", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "20", "20", "A", "", "89.9", "88.7", "", "82.2", "", "2", "1", "", "104", "1", "2", "46", "4", "0", "", "", "", "0", "", "", "", "", "1", "6.548", "0.074", "0.0029", "0.44307", "", "", "", "", "", "0", "", "", "0405", "", "A", "93", "XL", "94", "8", "68", "40.0", "90.2", "101.2", "", "", "", "", "99.1"]} +{"pcdb_id": 19172, "brand_name": "Baxi", "model_name": "430 COMBI 2.1", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 86.7, "comparative_hot_water_efficiency_pct": 81.3, "output_kw_max": 25.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0021, "loss_factor_f1_kwh_per_day": 0.37197, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["019172", "020101", "0", "2024/Oct/16 16:49", "Baxi Heating UK Ltd", "Baxi", "430 COMBI 2.1", "", "47-077-75", "2024", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "25", "25", "A", "", "88.8", "86.7", "", "81.3", "", "2", "", "", "104", "1", "2", "61", "4", "0", "", "", "", "0", "", "", "", "", "1", "6.474", "0.071", "0.0021", "0.37197", "", "", "", "", "", "0", "", "", "0405", "", "A", "93", "XL", "94", "9", "79", "40.0", "88.0", "98.9", "", "", "", "", "96.9"]} +{"pcdb_id": 19173, "brand_name": "Baxi", "model_name": "430 COMBI 2.1 LPG", "model_qualifier": "", "winter_efficiency_pct": 89.9, "summer_efficiency_pct": 88.6, "comparative_hot_water_efficiency_pct": 83.2, "output_kw_max": 25.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0021, "loss_factor_f1_kwh_per_day": 0.37197, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["019173", "020101", "0", "2024/Oct/16 16:54", "Baxi Heating UK Ltd", "Baxi", "430 COMBI 2.1 LPG", "", "47-077-75", "2024", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "25", "25", "A", "", "89.9", "88.6", "", "83.2", "", "2", "1", "", "104", "1", "2", "61", "4", "0", "", "", "", "0", "", "", "", "", "1", "6.474", "0.071", "0.0021", "0.37197", "", "", "", "", "", "0", "", "", "0405", "", "A", "93", "XL", "94", "9", "79", "40.0", "90.0", "101.1", "", "", "", "", "99.0"]} +{"pcdb_id": 19174, "brand_name": "Baxi", "model_name": "436 COMBI 2.1", "model_qualifier": "", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 86.7, "comparative_hot_water_efficiency_pct": 81.4, "output_kw_max": 25.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0021, "loss_factor_f1_kwh_per_day": 0.37024, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["019174", "020101", "0", "2024/Oct/16 16:58", "Baxi Heating UK Ltd", "Baxi", "436 COMBI 2.1", "", "47-077-76", "2024", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "25", "25", "A", "", "88.8", "86.7", "", "81.4", "", "2", "", "", "104", "1", "2", "71", "4", "0", "", "", "", "0", "", "", "", "", "1", "6.47", "0.071", "0.0021", "0.37024", "", "", "", "", "", "0", "", "", "0405", "", "A", "93", "XL", "94", "9", "85", "40.0", "88.1", "98.8", "", "", "", "", "96.8"]} +{"pcdb_id": 19175, "brand_name": "Baxi", "model_name": "436 COMBI 2.1 LPG", "model_qualifier": "", "winter_efficiency_pct": 89.8, "summer_efficiency_pct": 88.6, "comparative_hot_water_efficiency_pct": 83.2, "output_kw_max": 25.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0021, "loss_factor_f1_kwh_per_day": 0.37024, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["019175", "020101", "0", "2024/Oct/16 17:02", "Baxi Heating UK Ltd", "Baxi", "436 COMBI 2.1 LPG", "", "47-077-76", "2024", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "25", "25", "A", "", "89.8", "88.6", "", "83.2", "", "2", "1", "", "104", "1", "2", "71", "4", "0", "", "", "", "0", "", "", "", "", "1", "6.47", "0.071", "0.0021", "0.37024", "", "", "", "", "", "0", "", "", "0405", "", "A", "93", "XL", "94", "9", "85", "40.0", "90.1", "101.0", "", "", "", "", "99.0"]} +{"pcdb_id": 19176, "brand_name": "Baxi", "model_name": "424 COMBI 2", "model_qualifier": "", "winter_efficiency_pct": 88.5, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 62.4, "output_kw_max": 20.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["019176", "020101", "0", "2024/Dec/09 16:38", "Baxi Heating UK Ltd", "Baxi", "424 COMBI 2", "", "47-077-51", "2023", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "20", "20", "A", "", "88.5", "79.9", "", "62.4", "", "2", "", "", "104", "1", "2", "37", "4", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "", "", "0405", "", "A", "88", "XL", "93", "14", "76", "40.0", "88.2", "97.9", "", "", "", "", "96.1"]} +{"pcdb_id": 19177, "brand_name": "Baxi", "model_name": "430 COMBI 2", "model_qualifier": "", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 62.3, "output_kw_max": 20.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["019177", "020101", "0", "2024/Dec/09 16:43", "Baxi Heating UK Ltd", "Baxi", "430 COMBI 2", "", "47-077-52", "2023", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "20", "20", "A", "", "88.4", "79.8", "", "62.3", "", "2", "", "", "104", "1", "2", "26", "4", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "", "", "0405", "", "A", "89", "XL", "93", "14", "70", "40.0", "88.0", "97.8", "", "", "", "", "95.9"]} +{"pcdb_id": 19178, "brand_name": "Worcester", "model_name": "Greenstar 8000+", "model_qualifier": "GR8701iW 40 C LPG", "winter_efficiency_pct": 90.6, "summer_efficiency_pct": 88.9, "comparative_hot_water_efficiency_pct": 73.5, "output_kw_max": 33.7, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.01, "loss_factor_f1_kwh_per_day": 1.16664, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["019178", "020051", "0", "2024/Dec/04 15:32", "Bosch Thermotechnology Ltd", "Worcester", "Greenstar 8000+", "GR8701iW 40 C LPG", "47-800-53", "2024", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "16.9", "33.7", "A", "", "90.6", "88.9", "", "73.5", "", "2", "0", "2", "104", "1", "2", "48", "2", "0", "", "", "", "0", "", "", "", "", "1", "7.323", "0.112", "0.01", "1.16664", "", "", "", "", "", "0", "", "", "8305", "", "A", "86", "XL", "94", "13", "68", "71.0", "90.9", "99.9", "", "", "", "", "98.2"]} +{"pcdb_id": 19179, "brand_name": "Worcester", "model_name": "Greenstar 8000+", "model_qualifier": "GR8701iW 45 C LPG", "winter_efficiency_pct": 90.7, "summer_efficiency_pct": 89.1, "comparative_hot_water_efficiency_pct": 72.5, "output_kw_max": 33.8, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.002, "loss_factor_f1_kwh_per_day": 1.32645, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["019179", "020051", "0", "2024/Dec/04 19:07", "Bosch Thermotechnology Ltd", "Worcester", "Greenstar 8000+", "GR8701iW 45 C LPG", "47-800-54", "2024", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "16.9", "33.8", "A", "", "90.7", "89.1", "", "72.5", "", "2", "0", "2", "104", "1", "2", "48", "1", "0", "", "", "", "0", "", "", "", "", "1", "7.425", "0.106", "0.002", "1.32645", "", "", "", "", "", "0", "", "", "8305", "", "A", "86", "XL", "94", "13", "62", "71.0", "91.5", "100.1", "", "", "", "", "98.5"]} +{"pcdb_id": 19180, "brand_name": "Worcester", "model_name": "Greenstar 8000+", "model_qualifier": "GR8701iW 50 C LPG", "winter_efficiency_pct": 90.6, "summer_efficiency_pct": 89.1, "comparative_hot_water_efficiency_pct": 74.5, "output_kw_max": 33.8, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0025, "loss_factor_f1_kwh_per_day": 1.13294, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["019180", "020051", "0", "2024/Dec/04 19:23", "Bosch Thermotechnology Ltd", "Worcester", "Greenstar 8000+", "GR8701iW 50 C LPG", "47-800-55", "2024", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "16.9", "33.8", "A", "", "90.6", "89.1", "", "74.5", "", "2", "0", "2", "104", "1", "2", "48", "1", "0", "", "", "", "0", "", "", "", "", "1", "7.228", "0.115", "0.0025", "1.13294", "", "", "", "", "", "0", "", "", "8305", "", "A", "87", "XL", "94", "13", "62", "71.0", "91.5", "99.7", "", "", "", "", "98.2"]} +{"pcdb_id": 19181, "brand_name": "Worcester", "model_name": "Greenstar 8000+", "model_qualifier": "GR8701iW 45 R NG", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 42.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["019181", "020051", "0", "2024/Dec/04 14:46", "Bosch Thermotechnology Ltd", "Worcester", "Greenstar 8000+", "GR8701iW 45 R NG", "41-800-32", "2024", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "21.3", "42.6", "A", "", "89.2", "80.2", "", "58.6", "", "2", "", "", "102", "1", "2", "84", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "8305", "", "", "", "", "94", "14", "91", "67.0", "88.7", "99.5", "", "", "", "", "97.4"]} +{"pcdb_id": 19182, "brand_name": "Worcester", "model_name": "Greenstar 8000+", "model_qualifier": "GR8701iW 50 R NG", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.5, "output_kw_max": 47.8, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["019182", "020051", "0", "2025/Jan/03 08:45", "Bosch Thermotechnology Ltd", "Worcester", "Greenstar 8000+", "GR8701iW 50 R NG", "41-800-33", "2024", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "23.9", "47.8", "A", "", "89.0", "80.0", "", "58.5", "", "2", "", "", "102", "1", "2", "84", "1", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "8305", "", "", "", "", "94", "14", "85", "67.0", "88.6", "99.2", "", "", "", "", "97.2"]} +{"pcdb_id": 19183, "brand_name": "Worcester", "model_name": "Greenstar 8000+", "model_qualifier": "GR8701iW 30 S LPG", "winter_efficiency_pct": 90.5, "summer_efficiency_pct": 81.5, "comparative_hot_water_efficiency_pct": 59.5, "output_kw_max": 29.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["019183", "020051", "0", "2024/Dec/19 14:44", "Bosch Thermotechnology Ltd", "Worcester", "Greenstar 8000+", "GR8701iW 30 S LPG", "41-800-34", "2024", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "14.8", "29.6", "A", "", "90.5", "81.5", "", "59.5", "", "2", "0", "2", "102", "1", "2", "67", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "8305", "", "", "", "", "94", "14", "81", "71.0", "91.0", "99.7", "", "", "", "", "98.1"]} +{"pcdb_id": 19184, "brand_name": "Worcester", "model_name": "Greenstar 8000+", "model_qualifier": "GR8701iW 35 S LPG", "winter_efficiency_pct": 90.5, "summer_efficiency_pct": 81.5, "comparative_hot_water_efficiency_pct": 59.5, "output_kw_max": 33.7, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["019184", "020051", "0", "2024/Dec/19 15:56", "Bosch Thermotechnology Ltd", "Worcester", "Greenstar 8000+", "GR8701iW 35 S LPG", "41-800-35", "2024", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "16.9", "33.7", "A", "", "90.5", "81.5", "", "59.5", "", "2", "0", "2", "102", "1", "2", "48", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "8305", "", "", "", "", "94", "13", "68", "71.0", "90.9", "99.7", "", "", "", "", "98.1"]} +{"pcdb_id": 19185, "brand_name": "Worcester", "model_name": "Greenstar 8000+", "model_qualifier": "GR8701iW 30 R LPG", "winter_efficiency_pct": 90.5, "summer_efficiency_pct": 81.5, "comparative_hot_water_efficiency_pct": 59.5, "output_kw_max": 29.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["019185", "020051", "0", "2024/Dec/19 14:58", "Bosch Thermotechnology Ltd", "Worcester", "Greenstar 8000+", "GR8701iW 30 R LPG", "41-800-36", "2024", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "14.8", "29.6", "A", "", "90.5", "81.5", "", "59.5", "", "2", "0", "2", "102", "1", "2", "67", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "8305", "", "", "", "", "94", "14", "81", "71.0", "91.0", "99.7", "", "", "", "", "98.1"]} +{"pcdb_id": 19186, "brand_name": "Worcester", "model_name": "Greenstar 8000+", "model_qualifier": "GR8701iW 35 R LPG", "winter_efficiency_pct": 90.5, "summer_efficiency_pct": 81.5, "comparative_hot_water_efficiency_pct": 59.5, "output_kw_max": 33.7, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["019186", "020051", "0", "2024/Dec/19 15:57", "Bosch Thermotechnology Ltd", "Worcester", "Greenstar 8000+", "GR8701iW 35 R LPG", "41-800-37", "2024", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "16.9", "33.7", "A", "", "90.5", "81.5", "", "59.5", "", "2", "0", "2", "102", "1", "2", "48", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "8305", "", "", "", "", "94", "13", "68", "71.0", "90.9", "99.7", "", "", "", "", "98.1"]} +{"pcdb_id": 19187, "brand_name": "Worcester", "model_name": "Greenstar 8000+", "model_qualifier": "GR8701iW 40 R LPG", "winter_efficiency_pct": 90.6, "summer_efficiency_pct": 81.6, "comparative_hot_water_efficiency_pct": 59.6, "output_kw_max": 39.8, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["019187", "020051", "0", "2024/Dec/04 16:12", "Bosch Thermotechnology Ltd", "Worcester", "Greenstar 8000+", "GR8701iW 40 R LPG", "41-800-38", "2024", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "19.9", "39.8", "A", "", "90.6", "81.6", "", "59.6", "", "2", "0", "2", "102", "1", "2", "75", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "8305", "", "", "", "", "94", "14", "86", "71.0", "91.2", "99.9", "", "", "", "", "98.3"]} +{"pcdb_id": 19188, "brand_name": "Worcester", "model_name": "Greenstar 8000+", "model_qualifier": "GR8701iW 45 R LPG", "winter_efficiency_pct": 90.2, "summer_efficiency_pct": 81.2, "comparative_hot_water_efficiency_pct": 59.3, "output_kw_max": 42.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["019188", "020051", "0", "2024/Dec/04 17:34", "Bosch Thermotechnology Ltd", "Worcester", "Greenstar 8000+", "GR8701iW 45 R LPG", "41-800-39", "2024", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "21.3", "42.6", "A", "", "90.2", "81.2", "", "59.3", "", "2", "0", "2", "102", "1", "2", "84", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "8305", "", "", "", "", "94", "14", "91", "67.0", "90.9", "99.0", "", "", "", "", "97.5"]} +{"pcdb_id": 19189, "brand_name": "Worcester", "model_name": "Greenstar 8000+", "model_qualifier": "GR8701iW 50 R LPG", "winter_efficiency_pct": 90.1, "summer_efficiency_pct": 81.1, "comparative_hot_water_efficiency_pct": 59.3, "output_kw_max": 47.8, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["019189", "020051", "0", "2024/Dec/04 18:10", "Bosch Thermotechnology Ltd", "Worcester", "Greenstar 8000+", "GR8701iW 50 R LPG", "41-800-40", "2024", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "23.9", "47.8", "A", "", "90.1", "81.1", "", "59.3", "", "2", "0", "2", "102", "1", "2", "84", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "8305", "", "", "", "", "94", "14", "91", "67.0", "90.8", "98.9", "", "", "", "", "97.4"]} +{"pcdb_id": 19190, "brand_name": "Warmflow", "model_name": "B21", "model_qualifier": "Agentis HVO Boiler House 21", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 80.9, "comparative_hot_water_efficiency_pct": 59.1, "output_kw_max": 21.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["019190", "020103", "0", "2025/Feb/25 15:41", "Warmflow Engineering Ltd", "Warmflow", "B21", "Agentis HVO Boiler House 21", "", "2019", "current", "71", "1", "1", "1", "0", "", "", "2", "3", "2", "15", "21", "A", "", "88.7", "80.9", "", "59.1", "", "2", "", "", "201", "1", "1", "152", "0", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "91", "49", "188", "112.0", "91.8", "96.2", "", "", "", "", "95.4"]} +{"pcdb_id": 19191, "brand_name": "Warmflow", "model_name": "E21", "model_qualifier": "Agentis HVO External 21", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 80.9, "comparative_hot_water_efficiency_pct": 59.1, "output_kw_max": 21.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["019191", "020103", "0", "2025/Feb/25 15:45", "Warmflow Engineering Ltd", "Warmflow", "E21", "Agentis HVO External 21", "", "2019", "current", "71", "1", "2", "1", "0", "", "", "2", "3", "2", "15", "21", "A", "", "88.7", "80.9", "", "59.1", "", "2", "", "", "201", "1", "1", "152", "0", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "91", "49", "188", "112.0", "91.8", "96.2", "", "", "", "", "95.4"]} +{"pcdb_id": 19192, "brand_name": "Warmflow", "model_name": "I21", "model_qualifier": "Agentis HVO Internal 21", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 80.9, "comparative_hot_water_efficiency_pct": 59.1, "output_kw_max": 21.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["019192", "020103", "0", "2025/Feb/25 16:03", "Warmflow Engineering Ltd", "Warmflow", "I21", "Agentis HVO Internal 21", "", "2019", "current", "71", "1", "1", "1", "0", "", "", "2", "3", "2", "15", "21", "A", "", "88.7", "80.9", "", "59.1", "", "2", "", "", "201", "1", "1", "152", "0", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "91", "49", "188", "112.0", "91.8", "96.2", "", "", "", "", "95.4"]} +{"pcdb_id": 19193, "brand_name": "Warmflow", "model_name": "I21C", "model_qualifier": "Agentis HVO Internal Combi 21", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 90.0, "comparative_hot_water_efficiency_pct": 64.5, "output_kw_max": 21.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 1, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0, "loss_factor_f1_kwh_per_day": 2.30726, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["019193", "020103", "0", "2025/Feb/27 08:58", "Warmflow Engineering Ltd", "Warmflow", "I21C", "Agentis HVO Internal Combi 21", "", "2019", "current", "71", "1", "1", "2", "0", "", "", "2", "3", "2", "15", "21", "A", "", "88.7", "90.0", "", "64.5", "", "2", "", "", "203", "1", "1", "163", "3", "1", "2", "0", "38", "0", "20", "4", "58", "", "1", "8.487", "0.117", "0.0", "2.30726", "", "", "", "", "", "", "", "", "0003", "", "A", "82", "XL", "91", "53", "224", "112.0", "91.1", "96.5", "", "", "", "", "95.5"]} +{"pcdb_id": 19194, "brand_name": "Warmflow", "model_name": "E21C", "model_qualifier": "Agentis HVO External Combi 21", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 90.0, "comparative_hot_water_efficiency_pct": 64.5, "output_kw_max": 21.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 1, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0, "loss_factor_f1_kwh_per_day": 2.30726, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["019194", "020103", "0", "2025/Feb/25 16:56", "Warmflow Engineering Ltd", "Warmflow", "E21C", "Agentis HVO External Combi 21", "", "2019", "current", "71", "1", "2", "2", "0", "", "", "2", "3", "2", "15", "21", "A", "", "88.7", "90.0", "", "64.5", "", "2", "", "", "203", "1", "1", "163", "3", "1", "2", "0", "38", "0", "20", "4", "58", "", "1", "8.487", "0.117", "0.0", "2.30726", "", "", "", "", "", "", "", "", "0003", "", "A", "82", "XL", "91", "53", "224", "112.0", "91.1", "96.5", "", "", "", "", "95.5"]} +{"pcdb_id": 19195, "brand_name": "Warmflow", "model_name": "B26", "model_qualifier": "Agentis HVO Boiler House 26", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 27.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["019195", "020103", "0", "2025/Feb/26 09:51", "Warmflow Engineering Ltd", "Warmflow", "B26", "Agentis HVO Boiler House 26", "", "2019", "current", "71", "1", "1", "1", "0", "", "", "2", "3", "2", "21", "27", "A", "", "88.0", "80.2", "", "58.6", "", "2", "", "", "201", "1", "1", "146", "0", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "90", "47", "180", "110.0", "90.8", "94.7", "", "", "", "", "94.0"]} +{"pcdb_id": 19196, "brand_name": "Warmflow", "model_name": "E26", "model_qualifier": "Agentis HVO External 26", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 27.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["019196", "020103", "0", "2025/Feb/26 10:07", "Warmflow Engineering Ltd", "Warmflow", "E26", "Agentis HVO External 26", "", "2019", "current", "71", "1", "2", "1", "0", "", "", "2", "3", "2", "21", "27", "A", "", "88.0", "80.2", "", "58.6", "", "2", "", "", "201", "1", "1", "146", "0", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "90", "47", "180", "110.0", "90.8", "94.7", "", "", "", "", "94.0"]} +{"pcdb_id": 19197, "brand_name": "Warmflow", "model_name": "I26", "model_qualifier": "Agentis HVO Internal 26", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 27.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["019197", "020103", "0", "2025/Feb/26 10:16", "Warmflow Engineering Ltd", "Warmflow", "I26", "Agentis HVO Internal 26", "", "2019", "current", "71", "1", "1", "1", "0", "", "", "2", "3", "2", "21", "27", "A", "", "88.0", "80.2", "", "58.6", "", "2", "", "", "201", "1", "1", "146", "0", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "90", "47", "180", "110.0", "90.8", "94.7", "", "", "", "", "94.0"]} +{"pcdb_id": 19198, "brand_name": "Warmflow", "model_name": "I26C", "model_qualifier": "Agentis HVO Internal Combi 26", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 90.0, "comparative_hot_water_efficiency_pct": 62.6, "output_kw_max": 27.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 1, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0, "loss_factor_f1_kwh_per_day": 2.56085, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["019198", "020103", "0", "2025/Feb/26 10:33", "Warmflow Engineering Ltd", "Warmflow", "I26C", "Agentis HVO Internal Combi 26", "", "2019", "current", "71", "1", "1", "2", "0", "", "", "2", "3", "2", "21", "27", "A", "", "88.2", "90.0", "", "62.6", "", "2", "", "", "203", "1", "1", "140", "3", "1", "2", "0", "38", "0", "20", "4", "58", "", "1", "8.751", "0.108", "0.0", "2.56085", "", "", "", "", "", "", "", "", "0003", "", "A", "83", "XL", "90", "51", "196", "110.0", "91.1", "95.1", "", "", "", "", "94.3"]} +{"pcdb_id": 19199, "brand_name": "Warmflow", "model_name": "E26C", "model_qualifier": "Agentis HVO External Combi 26", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 90.0, "comparative_hot_water_efficiency_pct": 62.6, "output_kw_max": 27.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 1, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0, "loss_factor_f1_kwh_per_day": 2.56085, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["019199", "020103", "0", "2025/Feb/26 10:55", "Warmflow Engineering Ltd", "Warmflow", "E26C", "Agentis HVO External Combi 26", "", "2019", "current", "71", "1", "2", "2", "0", "", "", "2", "3", "2", "21", "27", "A", "", "88.2", "90.0", "", "62.6", "", "2", "", "", "203", "1", "1", "140", "3", "1", "2", "0", "38", "0", "20", "4", "58", "", "1", "8.751", "0.108", "0.0", "2.56085", "", "", "", "", "", "", "", "", "0003", "", "A", "83", "XL", "90", "51", "196", "110.0", "91.1", "95.1", "", "", "", "", "94.3"]} +{"pcdb_id": 19200, "brand_name": "Warmflow", "model_name": "B33", "model_qualifier": "Agentis HVO Boiler House 33", "winter_efficiency_pct": 87.1, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 32.7, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["019200", "020103", "0", "2025/Feb/27 10:21", "Warmflow Engineering Ltd", "Warmflow", "B33", "Agentis HVO Boiler House 33", "", "2019", "current", "71", "1", "1", "1", "0", "", "", "2", "3", "2", "27", "32.7", "A", "", "87.1", "79.3", "", "57.9", "", "2", "", "", "201", "1", "1", "147", "0", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "90", "45", "182", "119.0", "89.8", "93.0", "", "", "", "", "92.3"]} +{"pcdb_id": 19201, "brand_name": "Warmflow", "model_name": "E33", "model_qualifier": "Agentis HVO External 33", "winter_efficiency_pct": 87.1, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 32.7, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["019201", "020103", "0", "2025/Feb/27 10:31", "Warmflow Engineering Ltd", "Warmflow", "E33", "Agentis HVO External 33", "", "2019", "current", "71", "1", "2", "1", "0", "", "", "2", "3", "2", "27", "32.7", "A", "", "87.1", "79.3", "", "57.9", "", "2", "", "", "201", "1", "1", "147", "0", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "90", "45", "182", "119.0", "89.8", "93.0", "", "", "", "", "92.3"]} +{"pcdb_id": 19202, "brand_name": "Warmflow", "model_name": "I33", "model_qualifier": "Agentis HVO Internal 33", "winter_efficiency_pct": 87.1, "summer_efficiency_pct": 79.3, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 32.7, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["019202", "020103", "0", "2025/Feb/27 10:47", "Warmflow Engineering Ltd", "Warmflow", "I33", "Agentis HVO Internal 33", "", "2019", "current", "71", "1", "1", "1", "0", "", "", "2", "3", "2", "27", "32.7", "A", "", "87.1", "79.3", "", "57.9", "", "2", "", "", "201", "1", "1", "147", "0", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "90", "45", "182", "119.0", "89.8", "93.0", "", "", "", "", "92.3"]} +{"pcdb_id": 19203, "brand_name": "Warmflow", "model_name": "I33C", "model_qualifier": "Agentis HVO Internal Combi 33", "winter_efficiency_pct": 87.4, "summer_efficiency_pct": 89.9, "comparative_hot_water_efficiency_pct": 57.3, "output_kw_max": 32.7, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 1, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0, "loss_factor_f1_kwh_per_day": 3.31777, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["019203", "020103", "0", "2025/Feb/27 11:15", "Warmflow Engineering Ltd", "Warmflow", "I33C", "Agentis HVO Internal Combi 33", "", "2019", "current", "71", "1", "1", "2", "0", "", "", "2", "3", "2", "27", "32.7", "A", "", "87.4", "89.9", "", "57.3", "", "2", "", "", "203", "1", "1", "148", "3", "1", "2", "0", "38", "0", "20", "4", "58", "", "1", "9.552", "0.088", "0.0", "3.31777", "", "", "", "", "", "", "", "", "0003", "", "A", "85", "XL", "90", "49", "206", "119.0", "90.7", "93.3", "", "", "", "", "92.8"]} +{"pcdb_id": 19204, "brand_name": "Warmflow", "model_name": "E33C", "model_qualifier": "Agentis HVO External Combi 33", "winter_efficiency_pct": 87.4, "summer_efficiency_pct": 89.9, "comparative_hot_water_efficiency_pct": 57.3, "output_kw_max": 32.7, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 1, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0, "loss_factor_f1_kwh_per_day": 3.31777, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["019204", "020103", "0", "2025/Feb/27 11:28", "Warmflow Engineering Ltd", "Warmflow", "E33C", "Agentis HVO External Combi 33", "", "2019", "current", "71", "1", "2", "2", "0", "", "", "2", "3", "2", "27", "32.7", "A", "", "87.4", "89.9", "", "57.3", "", "2", "", "", "203", "1", "1", "148", "3", "1", "2", "0", "38", "0", "20", "4", "58", "", "1", "9.552", "0.088", "0.0", "3.31777", "", "", "", "", "", "", "", "", "0003", "", "A", "85", "XL", "90", "49", "206", "119.0", "90.7", "93.3", "", "", "", "", "92.8"]} +{"pcdb_id": 19205, "brand_name": "Warmflow", "model_name": "E44", "model_qualifier": "Agentis HVO External 44", "winter_efficiency_pct": 87.5, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 44.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["019205", "020103", "0", "2025/Feb/26 15:51", "Warmflow Engineering Ltd", "Warmflow", "E44", "Agentis HVO External 44", "", "2019", "current", "71", "1", "2", "1", "0", "", "", "2", "3", "2", "33", "44", "A", "", "87.5", "79.7", "", "58.2", "", "2", "", "", "201", "1", "1", "190", "0", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "91", "45", "235", "123.0", "89.7", "94.1", "", "", "", "", "93.2"]} +{"pcdb_id": 19206, "brand_name": "Warmflow", "model_name": "I44", "model_qualifier": "Agentis HVO Internal 44", "winter_efficiency_pct": 87.5, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 44.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["019206", "020103", "0", "2025/Feb/26 16:07", "Warmflow Engineering Ltd", "Warmflow", "I44", "Agentis HVO Internal 44", "", "2019", "current", "71", "1", "1", "1", "0", "", "", "2", "3", "2", "33", "44", "A", "", "87.5", "79.7", "", "58.2", "", "2", "", "", "201", "1", "1", "190", "0", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "91", "45", "235", "123.0", "89.7", "94.1", "", "", "", "", "93.2"]} +{"pcdb_id": 19207, "brand_name": "Vaillant", "model_name": "ecoTEC plus 610", "model_qualifier": "VU 10CS/1-5 (N-GB)", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 80.2, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 10.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["019207", "020033", "0", "2025/Mar/06 10:18", "Vaillant Group UK Ltd", "Vaillant", "ecoTEC plus 610", "VU 10CS/1-5 (N-GB)", "41-694-45", "2023", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "10", "10", "A", "", "89.2", "80.2", "", "58.6", "", "2", "1", "", "102", "1", "2", "17", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "00C5", "", "", "", "", "92", "13", "50", "42.0", "89.4", "99.7", "", "", "", "", "97.7"]} +{"pcdb_id": 19208, "brand_name": "Vaillant", "model_name": "ecoTEC plus 615", "model_qualifier": "VU 15CS/1-5 (N-GB)", "winter_efficiency_pct": 89.3, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 58.7, "output_kw_max": 15.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["019208", "020033", "0", "2025/Mar/06 10:38", "Vaillant Group UK Ltd", "Vaillant", "ecoTEC plus 615", "VU 15CS/1-5 (N-GB)", "41-694-46", "2023", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "15", "15", "A", "", "89.3", "80.3", "", "58.7", "", "2", "1", "", "102", "1", "2", "22", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "00C5", "", "", "", "", "93", "13", "53", "42.0", "89.3", "100.0", "", "", "", "", "98.0"]} +{"pcdb_id": 19209, "brand_name": "Vaillant", "model_name": "ecoTEC plus 620", "model_qualifier": "VU 20CS/1-5 (N-GB)", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 80.4, "comparative_hot_water_efficiency_pct": 58.7, "output_kw_max": 20.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["019209", "020033", "0", "2025/Mar/06 14:18", "Vaillant Group UK Ltd", "Vaillant", "ecoTEC plus 620", "VU 20CS/1-5 (N-GB)", "41-694-47", "2023", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "20", "20", "A", "", "89.4", "80.4", "", "58.7", "", "2", "1", "", "102", "1", "2", "31", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "00C5", "", "", "", "", "93", "14", "60", "47.0", "89.5", "100.2", "", "", "", "", "98.2"]} +{"pcdb_id": 19210, "brand_name": "Vaillant", "model_name": "ecoTEC plus 625", "model_qualifier": "VU 25C/S1-5 (N-GB)", "winter_efficiency_pct": 89.7, "summer_efficiency_pct": 80.7, "comparative_hot_water_efficiency_pct": 59.0, "output_kw_max": 25.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["019210", "020033", "0", "2025/Mar/06 14:15", "Vaillant Group UK Ltd", "Vaillant", "ecoTEC plus 625", "VU 25C/S1-5 (N-GB)", "41-694-48", "2023", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "25", "25", "A", "", "89.7", "80.7", "", "59.0", "", "2", "1", "", "102", "1", "2", "28", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "00C5", "", "", "", "", "94", "15", "61", "48.0", "90.1", "100.8", "", "", "", "", "98.7"]} +{"pcdb_id": 19211, "brand_name": "Vaillant", "model_name": "ecoTEC plus 630", "model_qualifier": "VU 30CS/1-5 (N-GB)", "winter_efficiency_pct": 89.6, "summer_efficiency_pct": 80.6, "comparative_hot_water_efficiency_pct": 58.9, "output_kw_max": 30.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["019211", "020033", "0", "2025/Mar/06 14:13", "Vaillant Group UK Ltd", "Vaillant", "ecoTEC plus 630", "VU 30CS/1-5 (N-GB)", "41-694-49", "2023", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "30", "30", "A", "", "89.6", "80.6", "", "58.9", "", "2", "1", "", "102", "1", "2", "36", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "00C5", "", "", "", "", "94", "16", "68", "45.0", "90.0", "100.5", "", "", "", "", "98.5"]} +{"pcdb_id": 19212, "brand_name": "Vaillant", "model_name": "ecoTEC plus 826", "model_qualifier": "VUW 20/26CS/1-5 (N-GB)", "winter_efficiency_pct": 89.4, "summer_efficiency_pct": 80.8, "comparative_hot_water_efficiency_pct": 63.1, "output_kw_max": 20.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["019212", "020033", "0", "2025/Mar/06 14:59", "Vaillant Group UK Ltd", "Vaillant", "ecoTEC plus 826", "VUW 20/26CS/1-5 (N-GB)", "47-044-92", "2023", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "20", "20", "A", "", "89.4", "80.8", "", "63.1", "", "2", "1", "", "104", "1", "2", "31", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "", "", "00C5", "", "A", "87", "XL", "93", "14", "60", "47.0", "89.5", "100.2", "", "001871", "", "", "98.2"]} +{"pcdb_id": 19213, "brand_name": "Vaillant", "model_name": "ecoTEC plus 832", "model_qualifier": "VUW 25/32CS/1-5 (N-GB)", "winter_efficiency_pct": 89.7, "summer_efficiency_pct": 81.1, "comparative_hot_water_efficiency_pct": 63.3, "output_kw_max": 25.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["019213", "020033", "0", "2025/Mar/06 16:34", "Vaillant Group UK Ltd", "Vaillant", "ecoTEC plus 832", "VUW 25/32CS/1-5 (N-GB)", "47-044-93", "2023", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "25", "25", "A", "", "89.7", "81.1", "", "63.3", "", "2", "1", "", "104", "1", "2", "28", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "", "", "00C5", "", "A", "84", "XL", "94", "15", "61", "49.0", "90.1", "100.8", "", "001894", "", "", "98.7"]} +{"pcdb_id": 19214, "brand_name": "Vaillant", "model_name": "ecoTEC plus 836", "model_qualifier": "VUW 30/36CS/1-5 (N-GB)", "winter_efficiency_pct": 89.6, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 63.2, "output_kw_max": 30.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["019214", "020033", "0", "2025/Mar/10 11:27", "Vaillant Group UK Ltd", "Vaillant", "ecoTEC plus 836", "VUW 30/36CS/1-5 (N-GB)", "47-044-94", "2023", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "30", "30", "A", "", "89.6", "81.0", "", "63.2", "", "2", "1", "", "104", "1", "2", "36", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "0", "", "", "00C5", "", "A", "87", "XL", "94", "16", "68", "49.0", "90.0", "100.5", "", "", "", "", "98.5"]} +{"pcdb_id": 19215, "brand_name": "Worcester", "model_name": "Greenstar 8000+", "model_qualifier": "GR8701iW 40 C NG", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 85.2, "comparative_hot_water_efficiency_pct": 69.8, "output_kw_max": 33.7, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.0045, "loss_factor_f1_kwh_per_day": 1.36871, "loss_factor_f2_kwh_per_day": 1.12425, "rejected_factor_f3_per_litre": 2e-05, "raw": ["019215", "020051", "0", "2025/Apr/14 12:12", "Bosch Thermotechnology Ltd", "Worcester", "Greenstar 8000+", "GR8701iW 40 C NG", "47-800-46", "2024", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "16.9", "33.7", "A", "", "88.2", "85.2", "", "69.8", "", "2", "", "", "104", "1", "2", "48", "2", "0", "", "", "", "0", "", "", "", "", "2", "7.545", "0.124", "0.0045", "1.36871", "13.689", "0.116", "0.0025", "1.12425", "0.00002", "0", "", "", "8305", "", "A", "86", "XL", "94", "13", "68", "71.0", "87.3", "97.6", "", "", "", "", "95.6"]} +{"pcdb_id": 19216, "brand_name": "Worcester", "model_name": "Greenstar 8000+", "model_qualifier": "GR8701iW 32 C NG", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 88.2, "comparative_hot_water_efficiency_pct": 71.2, "output_kw_max": 29.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.0035, "loss_factor_f1_kwh_per_day": 1.23834, "loss_factor_f2_kwh_per_day": 1.2317, "rejected_factor_f3_per_litre": 1e-05, "raw": ["019216", "020051", "0", "2025/Apr/11 15:12", "Bosch Thermotechnology Ltd", "Worcester", "Greenstar 8000+", "GR8701iW 32 C NG", "47-800-44", "2024", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "14.8", "29.6", "A", "", "88.4", "88.2", "", "71.2", "", "2", "", "", "104", "1", "2", "40", "2", "0", "", "", "", "0", "", "", "", "", "2", "7.398", "0.118", "0.0035", "1.23834", "13.195", "0.104", "0.0025", "1.2317", "0.00001", "0", "", "", "8305", "", "A", "81", "XL", "93", "12", "61", "71.0", "87.5", "98.1", "", "", "", "", "96.1"]} +{"pcdb_id": 19217, "brand_name": "Worcester", "model_name": "Greenstar 8000+", "model_qualifier": "GR8701iW 36 C NG", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 86.2, "comparative_hot_water_efficiency_pct": 71.4, "output_kw_max": 33.7, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.006, "loss_factor_f1_kwh_per_day": 1.19876, "loss_factor_f2_kwh_per_day": 1.0315, "rejected_factor_f3_per_litre": 3e-05, "raw": ["019217", "020051", "0", "2025/Apr/11 15:22", "Bosch Thermotechnology Ltd", "Worcester", "Greenstar 8000+", "GR8701iW 36 C NG", "47-800-45", "2024", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "16.9", "33.7", "A", "", "88.2", "86.2", "", "71.4", "", "2", "", "", "104", "1", "2", "48", "2", "0", "", "", "", "0", "", "", "", "", "2", "7.372", "0.115", "0.006", "1.19876", "13.445", "0.106", "0.003", "1.0315", "0.00003", "0", "", "", "8305", "", "A", "80", "XL", "94", "13", "68", "71.0", "87.5", "97.4", "", "", "", "", "95.5"]} +{"pcdb_id": 19218, "brand_name": "Worcester", "model_name": "Greenstar 8000+ Style", "model_qualifier": "GR8701iW 32 CB NG Style", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 88.2, "comparative_hot_water_efficiency_pct": 71.2, "output_kw_max": 29.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.0035, "loss_factor_f1_kwh_per_day": 1.23834, "loss_factor_f2_kwh_per_day": 1.2317, "rejected_factor_f3_per_litre": 1e-05, "raw": ["019218", "020051", "0", "2025/Apr/11 15:28", "Bosch Thermotechnology Ltd", "Worcester", "Greenstar 8000+ Style", "GR8701iW 32 CB NG Style", "47-800-49", "2024", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "14.8", "29.6", "A", "", "88.4", "88.2", "", "71.2", "", "2", "", "", "104", "1", "2", "40", "2", "0", "", "", "", "0", "", "", "", "", "2", "7.398", "0.118", "0.0035", "1.23834", "13.195", "0.104", "0.0025", "1.2317", "0.00001", "0", "", "", "8305", "", "A", "81", "XL", "93", "12", "61", "71.0", "87.5", "98.1", "", "", "", "", "96.1"]} +{"pcdb_id": 19219, "brand_name": "Worcester", "model_name": "Greenstar 8000+ Style", "model_qualifier": "GR8701iW 36 CB NG Style", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 86.2, "comparative_hot_water_efficiency_pct": 71.4, "output_kw_max": 33.7, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.006, "loss_factor_f1_kwh_per_day": 1.19876, "loss_factor_f2_kwh_per_day": 1.0315, "rejected_factor_f3_per_litre": 3e-05, "raw": ["019219", "020051", "0", "2025/Apr/11 15:32", "Bosch Thermotechnology Ltd", "Worcester", "Greenstar 8000+ Style", "GR8701iW 36 CB NG Style", "47-800-50", "2024", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "16.9", "33.7", "A", "", "88.2", "86.2", "", "71.4", "", "2", "", "", "104", "1", "2", "48", "2", "0", "", "", "", "0", "", "", "", "", "2", "7.372", "0.115", "0.006", "1.19876", "13.445", "0.106", "0.003", "1.0315", "0.00003", "0", "", "", "8305", "", "A", "80", "XL", "94", "13", "68", "71.0", "87.5", "97.4", "", "", "", "", "95.5"]} +{"pcdb_id": 19220, "brand_name": "Worcester", "model_name": "Greenstar 8000+", "model_qualifier": "GR8701iW 32 C LPG", "winter_efficiency_pct": 89.8, "summer_efficiency_pct": 90.3, "comparative_hot_water_efficiency_pct": 73.0, "output_kw_max": 29.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.006, "loss_factor_f1_kwh_per_day": 1.21756, "loss_factor_f2_kwh_per_day": 1.20522, "rejected_factor_f3_per_litre": 3e-05, "raw": ["019220", "020051", "0", "2025/Apr/14 10:17", "Bosch Thermotechnology Ltd", "Worcester", "Greenstar 8000+", "GR8701iW 32 C LPG", "47-800-51", "2024", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "14.8", "29.6", "A", "", "89.8", "90.3", "", "73.0", "", "2", "0", "2", "104", "1", "2", "40", "2", "0", "", "", "", "0", "", "", "", "", "2", "7.374", "0.118", "0.006", "1.21756", "13.226", "0.128", "0.0035", "1.20522", "0.00003", "0", "", "", "8305", "", "A", "81", "XL", "93", "12", "61", "71.0", "90.1", "98.5", "", "", "", "", "96.9"]} +{"pcdb_id": 19221, "brand_name": "Worcester", "model_name": "Greenstar 8000+", "model_qualifier": "GR8701iW 36 C LPG", "winter_efficiency_pct": 89.5, "summer_efficiency_pct": 90.3, "comparative_hot_water_efficiency_pct": 72.3, "output_kw_max": 33.7, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.006, "loss_factor_f1_kwh_per_day": 1.28244, "loss_factor_f2_kwh_per_day": 1.27728, "rejected_factor_f3_per_litre": 3e-05, "raw": ["019221", "020051", "0", "2025/Apr/14 10:58", "Bosch Thermotechnology Ltd", "Worcester", "Greenstar 8000+", "GR8701iW 36 C LPG", "47-800-52", "2024", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "16.9", "33.7", "A", "", "89.5", "90.3", "", "72.3", "", "2", "0", "2", "104", "1", "2", "48", "2", "0", "", "", "", "0", "", "", "", "", "2", "7.449", "0.119", "0.006", "1.28244", "13.35", "0.105", "0.0035", "1.27728", "0.00003", "0", "", "", "8305", "", "A", "80", "XL", "94", "13", "68", "71.0", "89.8", "97.6", "", "", "", "", "96.1"]} +{"pcdb_id": 19222, "brand_name": "Worcester", "model_name": "Greenstar 8000+", "model_qualifier": "GR8701iW 45 C NG", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 88.2, "comparative_hot_water_efficiency_pct": 71.7, "output_kw_max": 33.8, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.0035, "loss_factor_f1_kwh_per_day": 1.21388, "loss_factor_f2_kwh_per_day": 1.18565, "rejected_factor_f3_per_litre": 2e-05, "raw": ["019222", "020051", "0", "2025/Apr/30 11:20", "Bosch Thermotechnology Ltd", "Worcester", "Greenstar 8000+", "GR8701iW 45 C NG", "47-800-47", "2024", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "16.9", "33.8", "A", "", "88.8", "88.2", "", "71.7", "", "2", "", "", "104", "1", "2", "48", "2", "0", "", "", "", "0", "", "", "", "", "2", "7.35", "0.12", "0.0035", "1.21388", "13.26", "0.136", "0.0015", "1.18565", "0.00002", "0", "", "", "8305", "", "A", "86", "XL", "94", "13", "68", "71.0", "88.3", "98.7", "", "", "", "", "96.7"]} +{"pcdb_id": 19223, "brand_name": "Worcester", "model_name": "Greenstar 8000+", "model_qualifier": "GR8701iW 50 C NG", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 87.1, "comparative_hot_water_efficiency_pct": 70.0, "output_kw_max": 33.8, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.006, "loss_factor_f1_kwh_per_day": 1.36354, "loss_factor_f2_kwh_per_day": 1.24463, "rejected_factor_f3_per_litre": 3e-05, "raw": ["019223", "020051", "0", "2025/Apr/30 13:46", "Bosch Thermotechnology Ltd", "Worcester", "Greenstar 8000+", "GR8701iW 50 C NG", "47-800-48", "2024", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "16.9", "33.8", "A", "", "88.9", "87.1", "", "70.0", "", "2", "", "", "104", "1", "2", "48", "2", "0", "", "", "", "0", "", "", "", "", "2", "7.518", "0.113", "0.006", "1.36354", "13.526", "0.127", "0.003", "1.24463", "0.00003", "0", "", "", "8305", "", "A", "87", "XL", "94", "13", "68", "71.0", "88.4", "98.8", "", "", "", "", "96.9"]} +{"pcdb_id": 19224, "brand_name": "Grant", "model_name": "VORTEX PRO 15-26", "model_qualifier": "", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 81.1, "comparative_hot_water_efficiency_pct": 59.2, "output_kw_max": 26.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["019224", "020089", "0", "2025/Apr/28 16:37", "Grant Engineering (UK) Ltd", "Grant", "VORTEX PRO 15-26", "", "", "2022", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "15", "26", "A", "", "88.9", "81.1", "", "59.2", "", "2", "", "", "201", "1", "1", "152", "0", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "92", "53", "188", "45.0", "92.6", "96.3", "", "", "", "", "95.6"]} +{"pcdb_id": 19225, "brand_name": "Grant", "model_name": "VORTEX PRO SYSTEM 15-26", "model_qualifier": "", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 81.1, "comparative_hot_water_efficiency_pct": 59.2, "output_kw_max": 26.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["019225", "020089", "0", "2025/Apr/28 16:55", "Grant Engineering (UK) Ltd", "Grant", "VORTEX PRO SYSTEM 15-26", "", "", "2022", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "15", "26", "A", "", "88.9", "81.1", "", "59.2", "", "2", "", "", "201", "1", "1", "152", "0", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "92", "53", "188", "45.0", "92.6", "96.3", "", "", "", "", "95.6"]} +{"pcdb_id": 19226, "brand_name": "Grant", "model_name": "VORTEX PRO EXTERNAL 15-26", "model_qualifier": "", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 81.1, "comparative_hot_water_efficiency_pct": 59.2, "output_kw_max": 26.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["019226", "020089", "0", "2025/Apr/29 10:34", "Grant Engineering (UK) Ltd", "Grant", "VORTEX PRO EXTERNAL 15-26", "", "", "2022", "current", "4", "1", "2", "1", "0", "", "", "2", "1", "2", "15", "26", "A", "", "88.9", "81.1", "", "59.2", "", "2", "", "", "201", "1", "1", "152", "0", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "92", "53", "188", "45.0", "92.6", "96.3", "", "", "", "", "95.6"]} +{"pcdb_id": 19227, "brand_name": "Grant", "model_name": "VORTEX BOILER HOUSE 15-26", "model_qualifier": "", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 81.1, "comparative_hot_water_efficiency_pct": 59.2, "output_kw_max": 26.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["019227", "020089", "0", "2025/Apr/29 11:22", "Grant Engineering (UK) Ltd", "Grant", "VORTEX BOILER HOUSE 15-26", "", "", "2022", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "2", "15", "26", "A", "", "88.9", "81.1", "", "59.2", "", "2", "", "", "201", "1", "1", "152", "0", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0003", "", "", "", "", "92", "53", "188", "45.0", "92.6", "96.3", "", "", "", "", "95.6"]} +{"pcdb_id": 19228, "brand_name": "Worcester", "model_name": "Greenstar 8000+", "model_qualifier": "GR8701iW 30 S NG", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 29.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["019228", "020051", "0", "2025/Jun/19 15:46", "Bosch Thermotechnology Ltd", "Worcester", "Greenstar 8000+", "GR8701iW 30 S NG", "41-800-27", "2024", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "14.8", "29.6", "A", "", "88.8", "79.8", "", "58.3", "", "2", "", "", "102", "1", "2", "67", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "8305", "", "", "", "", "94", "14", "81", "71.0", "88.4", "98.7", "", "", "", "", "96.8"]} +{"pcdb_id": 19229, "brand_name": "Worcester", "model_name": "Greenstar 8000+", "model_qualifier": "GR8701iW 35 S NG", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 33.7, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["019229", "020051", "0", "2025/Jun/19 12:34", "Bosch Thermotechnology Ltd", "Worcester", "Greenstar 8000+", "GR8701iW 35 S NG", "41-800-28", "2024", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "16.9", "33.7", "A", "", "88.9", "79.9", "", "58.3", "", "2", "", "", "102", "1", "2", "48", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "8305", "", "", "", "", "94", "13", "68", "71.0", "88.3", "98.8", "", "", "", "", "96.8"]} +{"pcdb_id": 19230, "brand_name": "Worcester", "model_name": "Greenstar 8000+", "model_qualifier": "GR8701iW 30 R NG", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 29.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["019230", "020051", "0", "2025/Jun/19 13:49", "Bosch Thermotechnology Ltd", "Worcester", "Greenstar 8000+", "GR8701iW 30 R NG", "41-800-29", "2024", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "14.8", "29.6", "A", "", "88.8", "79.8", "", "58.3", "", "2", "", "", "102", "1", "2", "67", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "8305", "", "", "", "", "94", "14", "81", "71.0", "88.4", "98.7", "", "", "", "", "96.8"]} +{"pcdb_id": 19231, "brand_name": "Worcester", "model_name": "Greenstar 8000+", "model_qualifier": "GR8701iW 35 R NG", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 33.7, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["019231", "020051", "0", "2025/Jun/19 14:29", "Bosch Thermotechnology Ltd", "Worcester", "Greenstar 8000+", "GR8701iW 35 R NG", "41-800-30", "2024", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "16.9", "33.7", "A", "", "88.9", "79.9", "", "58.3", "", "2", "", "", "102", "1", "2", "48", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "8305", "", "", "", "", "94", "13", "68", "71.0", "88.3", "98.8", "", "", "", "", "96.8"]} +{"pcdb_id": 19232, "brand_name": "Worcester", "model_name": "Greenstar 8000+", "model_qualifier": "GR8701iW 40 R NG", "winter_efficiency_pct": 88.8, "summer_efficiency_pct": 79.8, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 33.7, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["019232", "020051", "0", "2025/Jun/19 15:25", "Bosch Thermotechnology Ltd", "Worcester", "Greenstar 8000+", "GR8701iW 40 R NG", "41-800-31", "2024", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "16.9", "33.7", "A", "", "88.8", "79.8", "", "58.3", "", "2", "", "", "102", "1", "2", "75", "2", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "8305", "", "", "", "", "94", "14", "86", "71.0", "88.1", "98.8", "", "", "", "", "96.8"]} +{"pcdb_id": 19233, "brand_name": "Worcester", "model_name": "Greenstar 8000+", "model_qualifier": "GR8701iW 32 C LPG V2", "winter_efficiency_pct": 90.3, "summer_efficiency_pct": 90.3, "comparative_hot_water_efficiency_pct": 70.9, "output_kw_max": 29.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.0045, "loss_factor_f1_kwh_per_day": 1.43327, "loss_factor_f2_kwh_per_day": 1.42056, "rejected_factor_f3_per_litre": 2e-05, "raw": ["019233", "020051", "0", "2025/Aug/21 15:31", "Bosch Thermotechnology Ltd", "Worcester", "Greenstar 8000+", "GR8701iW 32 C LPG V2", "47-800-51", "2025", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "14.8", "29.6", "A", "", "90.3", "90.3", "", "70.9", "", "2", "0", "2", "104", "1", "2", "57", "2", "0", "", "", "", "0", "", "", "", "", "2", "7.589", "0.113", "0.0045", "1.43327", "13.465", "0.13", "0.003", "1.42056", "0.00002", "0", "", "", "8305", "", "A", "85", "XL", "95", "12", "71", "71.0", "90.1", "99.6", "", "", "", "", "97.8"]} +{"pcdb_id": 19234, "brand_name": "Worcester", "model_name": "Greenstar 8000+", "model_qualifier": "GR8701iW 32 C NG V2", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 88.1, "comparative_hot_water_efficiency_pct": 70.2, "output_kw_max": 29.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.004, "loss_factor_f1_kwh_per_day": 1.34956, "loss_factor_f2_kwh_per_day": 1.31483, "rejected_factor_f3_per_litre": 2e-05, "raw": ["019234", "020051", "0", "2025/Aug/21 15:25", "Bosch Thermotechnology Ltd", "Worcester", "Greenstar 8000+", "GR8701iW 32 C NG V2", "47-800-44", "2025", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "14.8", "29.6", "A", "", "88.9", "88.1", "", "70.2", "", "2", "", "", "104", "1", "2", "57", "2", "0", "", "", "", "0", "", "", "", "", "2", "7.499", "0.113", "0.004", "1.34956", "13.449", "0.128", "0.0025", "1.31483", "0.00002", "0", "", "", "8305", "", "A", "85", "XL", "94", "12", "71", "71.0", "88.1", "99.0", "", "", "", "", "96.9"]} +{"pcdb_id": 19235, "brand_name": "Worcester", "model_name": "Greenstar 8000+ Style", "model_qualifier": "GR8701iW 32 CB NG Style V2", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 88.1, "comparative_hot_water_efficiency_pct": 70.2, "output_kw_max": 29.6, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.004, "loss_factor_f1_kwh_per_day": 1.34956, "loss_factor_f2_kwh_per_day": 1.31483, "rejected_factor_f3_per_litre": 2e-05, "raw": ["019235", "020051", "0", "2025/Aug/21 15:37", "Bosch Thermotechnology Ltd", "Worcester", "Greenstar 8000+ Style", "GR8701iW 32 CB NG Style V2", "47-800-49", "2025", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "14.8", "29.6", "A", "", "88.9", "88.1", "", "70.2", "", "2", "", "", "104", "1", "2", "57", "2", "0", "", "", "", "0", "", "", "", "", "2", "7.499", "0.113", "0.004", "1.34956", "13.449", "0.128", "0.0025", "1.31483", "0.00002", "0", "", "", "8305", "", "A", "85", "XL", "93", "12", "71", "71.0", "88.1", "99.0", "", "", "", "", "96.9"]} +{"pcdb_id": 19236, "brand_name": "Navien", "model_name": "NCB300", "model_qualifier": "NCB300-30K", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 88.2, "comparative_hot_water_efficiency_pct": 70.4, "output_kw_max": 24.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.0245, "loss_factor_f1_kwh_per_day": 1.21005, "loss_factor_f2_kwh_per_day": 1.18378, "rejected_factor_f3_per_litre": 0.00023, "raw": ["019236", "020178", "0", "2025/Sep/19 10:20", "Navien UK", "Navien", "NCB300", "NCB300-30K", "47-709-17", "2024", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "A", "", "88.1", "88.2", "", "70.4", "", "2", "", "", "104", "1", "2", "39", "3", "0", "", "", "", "0", "", "", "", "", "2", "7.476", "0.125", "0.0245", "1.21005", "13.146", "0.142", "0.002", "1.18378", "0.00023", "0", "", "", "0005", "", "A", "83", "XL", "93", "17", "78", "78.0", "88.2", "96.9", "", "", "", "", "95.3"]} +{"pcdb_id": 19237, "brand_name": "Navien", "model_name": "NCB300", "model_qualifier": "NCB300-30K", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 90.3, "comparative_hot_water_efficiency_pct": 73.3, "output_kw_max": 24.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.0065, "loss_factor_f1_kwh_per_day": 1.18048, "loss_factor_f2_kwh_per_day": 1.17539, "rejected_factor_f3_per_litre": 4e-05, "raw": ["019237", "020178", "0", "2025/Sep/19 10:32", "Navien UK", "Navien", "NCB300", "NCB300-30K", "47-709-17", "2024", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "A", "", "88.7", "90.3", "", "73.3", "", "2", "0", "2", "104", "1", "2", "39", "3", "0", "", "", "", "0", "", "", "", "", "2", "7.346", "0.111", "0.0065", "1.18048", "13.261", "0.135", "0.0025", "1.17539", "0.00004", "0", "", "", "0005", "", "A", "83", "XL", "93", "17", "78", "78.0", "89.8", "95.7", "", "", "", "", "94.6"]} +{"pcdb_id": 19238, "brand_name": "Navien", "model_name": "NCB500", "model_qualifier": "NCB500-1S+/30K", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 87.4, "comparative_hot_water_efficiency_pct": 69.7, "output_kw_max": 24.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.002, "loss_factor_f1_kwh_per_day": 1.42558, "loss_factor_f2_kwh_per_day": 1.32039, "rejected_factor_f3_per_litre": 1e-05, "raw": ["019238", "020178", "0", "2025/Sep/19 11:01", "Navien UK", "Navien", "NCB500", "NCB500-1S+/30K", "47-709-18", "2024", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "A", "", "88.3", "87.4", "", "69.7", "", "2", "", "", "104", "1", "2", "39", "3", "0", "", "", "", "0", "", "", "", "", "2", "7.553", "0.127", "0.002", "1.42558", "13.551", "0.141", "0.0015", "1.32039", "0.00001", "0", "", "", "0005", "", "A", "85", "XL", "93", "17", "78", "78.0", "88.6", "97.4", "", "", "", "", "95.7"]} +{"pcdb_id": 19239, "brand_name": "Navien", "model_name": "NCB500", "model_qualifier": "NCB500-1S+/30K", "winter_efficiency_pct": 89.8, "summer_efficiency_pct": 88.7, "comparative_hot_water_efficiency_pct": 70.3, "output_kw_max": 24.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 2, "rejected_energy_proportion_r1": 0.002, "loss_factor_f1_kwh_per_day": 1.54088, "loss_factor_f2_kwh_per_day": 1.36976, "rejected_factor_f3_per_litre": 1e-05, "raw": ["019239", "020178", "0", "2025/Sep/19 12:18", "Navien UK", "Navien", "NCB500", "NCB500-1S+/30K", "47-709-18", "2024", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "24", "24", "A", "", "89.8", "88.7", "", "70.3", "", "2", "0", "2", "104", "1", "2", "39", "3", "0", "", "", "", "0", "", "", "", "", "2", "7.657", "0.122", "0.002", "1.54088", "13.69", "0.141", "0.001", "1.36976", "0.00001", "0", "", "", "0005", "", "A", "85", "XL", "93", "17", "78", "78.0", "91.1", "97.8", "", "", "", "", "96.5"]} +{"pcdb_id": 19240, "brand_name": "Navien", "model_name": "NCB500", "model_qualifier": "NCB500-15K System", "winter_efficiency_pct": 89.0, "summer_efficiency_pct": 80.0, "comparative_hot_water_efficiency_pct": 58.4, "output_kw_max": 15.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["019240", "020178", "0", "2025/Sep/19 12:51", "Navien UK", "Navien", "NCB500", "NCB500-15K System", "41-709-09", "2024", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "15", "15", "A", "", "89.0", "80.0", "", "58.4", "", "2", "", "", "102", "1", "2", "36", "3", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "93", "6", "52", "127.0", "87.3", "99.6", "", "", "", "", "97.2"]} +{"pcdb_id": 19241, "brand_name": "Navien", "model_name": "NCB500", "model_qualifier": "NCB500-15K System", "winter_efficiency_pct": 90.2, "summer_efficiency_pct": 81.2, "comparative_hot_water_efficiency_pct": 59.3, "output_kw_max": 15.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["019241", "020178", "0", "2025/Sep/19 13:02", "Navien UK", "Navien", "NCB500", "NCB500-15K System", "41-709-09", "2024", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "15", "15", "A", "", "90.2", "81.2", "", "59.3", "", "2", "0", "2", "102", "1", "2", "36", "3", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "93", "6", "52", "127.0", "90.4", "99.2", "", "", "", "", "97.5"]} +{"pcdb_id": 19242, "brand_name": "Navien", "model_name": "NCB500", "model_qualifier": "NCB500-18K System", "winter_efficiency_pct": 89.3, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 58.6, "output_kw_max": 18.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["019242", "020178", "0", "2025/Sep/19 14:35", "Navien UK", "Navien", "NCB500", "NCB500-18K System", "41-709-10", "2024", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "18", "18", "A", "", "89.3", "80.3", "", "58.6", "", "2", "", "", "102", "1", "2", "47", "3", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "93", "11", "69", "127.0", "88.2", "99.9", "", "", "", "", "97.7"]} +{"pcdb_id": 19243, "brand_name": "Navien", "model_name": "NCB500", "model_qualifier": "NCB500-18K System", "winter_efficiency_pct": 90.5, "summer_efficiency_pct": 81.5, "comparative_hot_water_efficiency_pct": 59.5, "output_kw_max": 18.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["019243", "020178", "0", "2025/Sep/19 14:44", "Navien UK", "Navien", "NCB500", "NCB500-18K System", "41-709-10", "2024", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "18", "18", "A", "", "90.5", "81.5", "", "59.5", "", "2", "0", "2", "102", "1", "2", "47", "3", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "93", "11", "69", "127.0", "90.4", "100.1", "", "", "", "", "98.3"]} +{"pcdb_id": 19244, "brand_name": "Navien", "model_name": "NCB500", "model_qualifier": "NCB500-24K System", "winter_efficiency_pct": 88.1, "summer_efficiency_pct": 79.1, "comparative_hot_water_efficiency_pct": 57.8, "output_kw_max": 24.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["019244", "020178", "0", "2025/Sep/19 15:03", "Navien UK", "Navien", "NCB500", "NCB500-24K System", "41-709-11", "2024", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "24", "24", "A", "", "88.1", "79.1", "", "57.8", "", "2", "", "", "102", "1", "2", "39", "3", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "93", "17", "78", "78.0", "88.2", "96.9", "", "", "", "", "95.3"]} +{"pcdb_id": 19245, "brand_name": "Navien", "model_name": "NCB500", "model_qualifier": "NCB500-24K System", "winter_efficiency_pct": 88.7, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 58.2, "output_kw_max": 24.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["019245", "020178", "0", "2025/Sep/19 15:11", "Navien UK", "Navien", "NCB500", "NCB500-24K System", "41-709-11", "2024", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "24", "24", "A", "", "88.7", "79.7", "", "58.2", "", "2", "0", "2", "102", "1", "2", "39", "3", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "93", "17", "78", "78.0", "89.8", "95.7", "", "", "", "", "94.6"]} +{"pcdb_id": 19246, "brand_name": "Navien", "model_name": "NCB500", "model_qualifier": "NCB500-30K System", "winter_efficiency_pct": 88.9, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 30.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["019246", "020178", "0", "2025/Sep/19 15:24", "Navien UK", "Navien", "NCB500", "NCB500-30K System", "41-709-12", "2024", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "30", "30", "A", "", "88.9", "79.9", "", "58.3", "", "2", "", "", "102", "1", "2", "39", "3", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "93", "19", "82", "127.0", "86.9", "99.5", "", "", "", "", "97.1"]} +{"pcdb_id": 19247, "brand_name": "Navien", "model_name": "NCB500", "model_qualifier": "NCB500-30K System", "winter_efficiency_pct": 90.4, "summer_efficiency_pct": 81.4, "comparative_hot_water_efficiency_pct": 59.4, "output_kw_max": 30.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["019247", "020178", "0", "2025/Sep/22 16:59", "Navien UK", "Navien", "NCB500", "NCB500-30K System", "41-709-12", "2024", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "30", "30", "A", "", "90.4", "81.4", "", "59.4", "", "2", "0", "2", "102", "1", "2", "39", "3", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "93", "19", "82", "127.0", "89.6", "100.5", "", "", "", "", "98.4"]} +{"pcdb_id": 19248, "brand_name": "Worcester", "model_name": "GREENSTAR DANESMOOR EXT", "model_qualifier": "12/18 2022+", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 81.4, "comparative_hot_water_efficiency_pct": 59.5, "output_kw_max": 18.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["019248", "020051", "0", "2025/Oct/17 16:16", "Bosch Thermotechnology Ltd", "Worcester", "GREENSTAR DANESMOOR EXT", "12/18 2022+", "", "2022", "current", "4", "1", "2", "1", "0", "", "", "2", "2", "1", "13", "18", "A", "", "89.2", "81.4", "", "59.5", "", "2", "", "", "201", "1", "1", "165", "0", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "8303", "", "", "", "", "92", "53", "204", "166.0", "91.7", "97.4", "", "", "", "", "96.4"]} +{"pcdb_id": 19249, "brand_name": "Worcester", "model_name": "GREENSTAR DANESMOOR EXT", "model_qualifier": "18/25 2022+", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 58.8, "output_kw_max": 25.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["019249", "020051", "0", "2025/Oct/17 16:17", "Bosch Thermotechnology Ltd", "Worcester", "GREENSTAR DANESMOOR EXT", "18/25 2022+", "", "2022", "current", "4", "1", "2", "1", "0", "", "", "2", "2", "1", "18", "25", "A", "", "88.3", "80.5", "", "58.8", "", "2", "", "", "201", "1", "1", "159", "0", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "8303", "", "", "", "", "92", "49", "197", "159.0", "91.8", "95.2", "", "", "", "", "94.6"]} +{"pcdb_id": 19250, "brand_name": "Worcester", "model_name": "GREENSTAR DANESMOOR EXT", "model_qualifier": "25/32 2022+", "winter_efficiency_pct": 87.7, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 32.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["019250", "020051", "0", "2025/Oct/17 16:18", "Bosch Thermotechnology Ltd", "Worcester", "GREENSTAR DANESMOOR EXT", "25/32 2022+", "", "2022", "current", "4", "1", "2", "1", "0", "", "", "2", "2", "1", "25", "32", "A", "", "87.7", "79.9", "", "58.3", "", "2", "", "", "201", "1", "1", "150", "0", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "8303", "", "", "", "", "92", "47", "185", "161.0", "91.5", "93.7", "", "", "", "", "93.3"]} +{"pcdb_id": 19251, "brand_name": "Worcester", "model_name": "GREENSTAR DANESMOOR UTY", "model_qualifier": "12/18 2022+", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 81.4, "comparative_hot_water_efficiency_pct": 59.5, "output_kw_max": 18.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["019251", "020051", "0", "2025/Oct/17 16:18", "Bosch Thermotechnology Ltd", "Worcester", "GREENSTAR DANESMOOR UTY", "12/18 2022+", "", "2022", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "13", "18", "A", "", "89.2", "81.4", "", "59.5", "", "2", "", "", "201", "1", "1", "165", "0", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "8303", "", "", "", "", "92", "53", "204", "166.0", "91.7", "97.4", "", "", "", "", "96.4"]} +{"pcdb_id": 19252, "brand_name": "Worcester", "model_name": "GREENSTAR DANESMOOR UTY", "model_qualifier": "18/25 2022+", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 58.8, "output_kw_max": 25.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["019252", "020051", "0", "2025/Oct/17 16:20", "Bosch Thermotechnology Ltd", "Worcester", "GREENSTAR DANESMOOR UTY", "18/25 2022+", "", "2022", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "18", "25", "A", "", "88.3", "80.5", "", "58.8", "", "2", "", "", "201", "1", "1", "159", "0", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "8303", "", "", "", "", "92", "49", "197", "159.0", "91.8", "95.2", "", "", "", "", "94.6"]} +{"pcdb_id": 19253, "brand_name": "Worcester", "model_name": "GREENSTAR DANESMOOR UTY", "model_qualifier": "25/32 2022+", "winter_efficiency_pct": 87.7, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 32.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["019253", "020051", "0", "2025/Oct/17 16:21", "Bosch Thermotechnology Ltd", "Worcester", "GREENSTAR DANESMOOR UTY", "25/32 2022+", "", "2022", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "25", "32", "A", "", "87.7", "79.9", "", "58.3", "", "2", "", "", "201", "1", "1", "150", "0", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "8303", "", "", "", "", "92", "47", "185", "161.0", "91.5", "93.7", "", "", "", "", "93.3"]} +{"pcdb_id": 19254, "brand_name": "Worcester", "model_name": "GREENSTAR HEATSLAVE II", "model_qualifier": "12/18 2022+", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 83.1, "comparative_hot_water_efficiency_pct": 43.3, "output_kw_max": 18.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 1, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["019254", "020051", "0", "2025/Oct/27 11:09", "Bosch Thermotechnology Ltd", "Worcester", "GREENSTAR HEATSLAVE II", "12/18 2022+", "", "2022", "current", "4", "1", "1", "2", "0", "", "", "2", "3", "1", "13", "18", "A", "", "89.2", "83.1", "", "43.3", "", "2", "", "", "203", "1", "1", "165", "2", "1", "1", "0", "62", "0", "25", "3", "84", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "8303", "", "B", "66", "XL", "92", "53", "219", "166.0", "91.7", "97.4", "", "", "", "", "96.4"]} +{"pcdb_id": 19255, "brand_name": "Worcester", "model_name": "GREENSTAR HEATSLAVE II", "model_qualifier": "18/25 2022+", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 82.2, "comparative_hot_water_efficiency_pct": 42.7, "output_kw_max": 25.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 1, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["019255", "020051", "0", "2025/Oct/27 11:10", "Bosch Thermotechnology Ltd", "Worcester", "GREENSTAR HEATSLAVE II", "18/25 2022+", "", "2022", "current", "4", "1", "1", "2", "0", "", "", "2", "3", "1", "18", "25", "A", "", "88.3", "82.2", "", "42.7", "", "2", "", "", "203", "1", "1", "159", "2", "1", "1", "0", "63", "0", "25", "3", "86", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "8303", "", "B", "63", "XL", "92", "49", "212", "159.0", "91.8", "95.2", "", "", "", "", "94.6"]} +{"pcdb_id": 19256, "brand_name": "Worcester", "model_name": "GREENSTAR HEATSLAVE II", "model_qualifier": "25/32 2022+", "winter_efficiency_pct": 87.7, "summer_efficiency_pct": 81.6, "comparative_hot_water_efficiency_pct": 42.2, "output_kw_max": 32.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 1, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["019256", "020051", "0", "2025/Oct/27 11:11", "Bosch Thermotechnology Ltd", "Worcester", "GREENSTAR HEATSLAVE II", "25/32 2022+", "", "2022", "current", "4", "1", "1", "2", "0", "", "", "2", "3", "1", "25", "32", "A", "", "87.7", "81.6", "", "42.2", "", "2", "", "", "203", "1", "1", "150", "2", "1", "1", "0", "64", "0", "25", "3", "88", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "8303", "", "B", "64", "XL", "92", "47", "200", "161.0", "91.5", "93.7", "", "", "", "", "93.3"]} +{"pcdb_id": 19257, "brand_name": "Worcester", "model_name": "GREENSTAR HEATSLAVE II EXT", "model_qualifier": "12/18 2022+", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 83.1, "comparative_hot_water_efficiency_pct": 43.3, "output_kw_max": 18.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 1, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["019257", "020051", "0", "2025/Oct/28 10:05", "Bosch Thermotechnology Ltd", "Worcester", "GREENSTAR HEATSLAVE II EXT", "12/18 2022+", "", "2022", "current", "4", "1", "2", "2", "0", "", "", "2", "2", "2", "13", "18", "A", "", "89.2", "83.1", "", "43.3", "", "2", "", "", "203", "1", "1", "165", "2", "1", "1", "0", "62", "0", "25", "3", "84", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "8303", "", "B", "66", "XL", "92", "53", "219", "166.0", "91.7", "97.4", "", "", "", "", "96.4"]} +{"pcdb_id": 19258, "brand_name": "Worcester", "model_name": "GREENSTAR HEATSLAVE II EXT", "model_qualifier": "18/25 2022+", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 82.2, "comparative_hot_water_efficiency_pct": 42.7, "output_kw_max": 25.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 1, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["019258", "020051", "0", "2025/Oct/28 10:27", "Bosch Thermotechnology Ltd", "Worcester", "GREENSTAR HEATSLAVE II EXT", "18/25 2022+", "", "2022", "current", "4", "1", "2", "2", "0", "", "", "2", "2", "2", "18", "25", "A", "", "88.3", "82.2", "", "42.7", "", "2", "", "", "203", "1", "1", "159", "2", "1", "1", "0", "63", "0", "25", "3", "86", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "8303", "", "B", "63", "XL", "92", "49", "212", "159.0", "91.8", "95.2", "", "", "", "", "94.6"]} +{"pcdb_id": 19259, "brand_name": "Worcester", "model_name": "GREENSTAR HEATSLAVE II EXT", "model_qualifier": "25/32 2022+", "winter_efficiency_pct": 89.1, "summer_efficiency_pct": 83.0, "comparative_hot_water_efficiency_pct": 42.9, "output_kw_max": 32.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 1, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["019259", "020051", "0", "2025/Oct/28 10:35", "Bosch Thermotechnology Ltd", "Worcester", "GREENSTAR HEATSLAVE II EXT", "25/32 2022+", "", "2022", "current", "4", "1", "2", "2", "0", "", "", "2", "2", "2", "25", "32", "A", "", "89.1", "83.0", "", "42.9", "", "2", "", "", "203", "1", "1", "150", "2", "1", "1", "0", "64", "0", "25", "3", "88", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "8303", "", "B", "64", "XL", "92", "47", "200", "161.0", "91.5", "97.3", "", "", "", "", "96.2"]} +{"pcdb_id": 19260, "brand_name": "Worcester", "model_name": "GREENSTAR DANESMOOR UTY", "model_qualifier": "32/50 2022+", "winter_efficiency_pct": 87.7, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 50.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["019260", "020051", "0", "2025/Oct/17 16:32", "Bosch Thermotechnology Ltd", "Worcester", "GREENSTAR DANESMOOR UTY", "32/50 2022+", "", "2022", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "32", "50", "A", "", "87.7", "79.9", "", "58.3", "", "2", "", "", "201", "1", "1", "198", "0", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "8303", "", "", "", "", "91", "62", "245", "258.0", "91.3", "93.8", "", "", "", "", "93.3"]} +{"pcdb_id": 19261, "brand_name": "Worcester", "model_name": "GREENSTAR DANESMOOR SYS EXT", "model_qualifier": "12/18 2022+", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 81.4, "comparative_hot_water_efficiency_pct": 59.5, "output_kw_max": 18.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["019261", "020051", "0", "2025/Oct/17 16:33", "Bosch Thermotechnology Ltd", "Worcester", "GREENSTAR DANESMOOR SYS EXT", "12/18 2022+", "", "2022", "current", "4", "1", "2", "1", "0", "", "", "2", "2", "1", "13", "18", "A", "", "89.2", "81.4", "", "59.5", "", "2", "", "", "201", "1", "1", "165", "0", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "8303", "", "", "", "", "92", "53", "204", "166.0", "91.7", "97.4", "", "", "", "", "96.4"]} +{"pcdb_id": 19262, "brand_name": "Worcester", "model_name": "GREENSTAR DANESMOOR SYS EXT", "model_qualifier": "18/25 2022+", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 58.8, "output_kw_max": 25.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["019262", "020051", "0", "2025/Oct/17 16:34", "Bosch Thermotechnology Ltd", "Worcester", "GREENSTAR DANESMOOR SYS EXT", "18/25 2022+", "", "2022", "current", "4", "1", "2", "1", "0", "", "", "2", "2", "1", "18", "25", "A", "", "88.3", "80.5", "", "58.8", "", "2", "", "", "201", "1", "1", "159", "0", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "8303", "", "", "", "", "92", "49", "197", "159.0", "91.8", "95.2", "", "", "", "", "94.6"]} +{"pcdb_id": 19263, "brand_name": "Worcester", "model_name": "GREENSTAR DANESMOOR SYS EXT", "model_qualifier": "25/32 2022+", "winter_efficiency_pct": 87.7, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 32.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["019263", "020051", "0", "2025/Oct/17 16:34", "Bosch Thermotechnology Ltd", "Worcester", "GREENSTAR DANESMOOR SYS EXT", "25/32 2022+", "", "2022", "current", "4", "1", "2", "1", "0", "", "", "2", "2", "1", "25", "32", "A", "", "87.7", "79.9", "", "58.3", "", "2", "", "", "201", "1", "1", "150", "0", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "8303", "", "", "", "", "92", "47", "185", "161.0", "91.5", "93.7", "", "", "", "", "93.3"]} +{"pcdb_id": 19264, "brand_name": "Worcester", "model_name": "GREENSTAR DANESMOOR", "model_qualifier": "12/18 2022+", "winter_efficiency_pct": 89.2, "summer_efficiency_pct": 81.4, "comparative_hot_water_efficiency_pct": 59.5, "output_kw_max": 18.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["019264", "020051", "0", "2025/Oct/17 16:35", "Bosch Thermotechnology Ltd", "Worcester", "GREENSTAR DANESMOOR", "12/18 2022+", "", "2022", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "13", "18", "A", "", "89.2", "81.4", "", "59.5", "", "2", "", "", "201", "1", "1", "165", "0", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "8303", "", "", "", "", "92", "53", "204", "166.0", "91.7", "97.4", "", "", "", "", "96.4"]} +{"pcdb_id": 19265, "brand_name": "Worcester", "model_name": "GREENSTAR DANESMOOR", "model_qualifier": "18/25 2022+", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 80.5, "comparative_hot_water_efficiency_pct": 58.8, "output_kw_max": 25.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["019265", "020051", "0", "2025/Oct/17 16:36", "Bosch Thermotechnology Ltd", "Worcester", "GREENSTAR DANESMOOR", "18/25 2022+", "", "2022", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "18", "25", "A", "", "88.3", "80.5", "", "58.8", "", "2", "", "", "201", "1", "1", "159", "0", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "8303", "", "", "", "", "92", "49", "197", "159.0", "91.8", "95.2", "", "", "", "", "94.6"]} +{"pcdb_id": 19266, "brand_name": "Worcester", "model_name": "GREENSTAR DANESMOOR", "model_qualifier": "25/32 2022+", "winter_efficiency_pct": 87.7, "summer_efficiency_pct": 79.9, "comparative_hot_water_efficiency_pct": 58.3, "output_kw_max": 32.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["019266", "020051", "0", "2025/Oct/17 16:36", "Bosch Thermotechnology Ltd", "Worcester", "GREENSTAR DANESMOOR", "25/32 2022+", "", "2022", "current", "4", "1", "1", "1", "0", "", "", "2", "3", "1", "25", "32", "A", "", "87.7", "79.9", "", "58.3", "", "2", "", "", "201", "1", "1", "150", "0", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "8303", "", "", "", "", "92", "47", "185", "161.0", "91.5", "93.7", "", "", "", "", "93.3"]} +{"pcdb_id": 19267, "brand_name": "Worcester", "model_name": "Greenstar 8000 F", "model_qualifier": "GR8700iF 35 C NG", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 86.7, "comparative_hot_water_efficiency_pct": 68.7, "output_kw_max": 33.8, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0075, "loss_factor_f1_kwh_per_day": 1.48868, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["019267", "020051", "0", "2025/Nov/27 09:53", "Bosch Thermotechnology Ltd", "Worcester", "Greenstar 8000 F", "GR8700iF 35 C NG", "47-800-56", "2025", "current", "1", "1", "1", "2", "0", "", "", "2", "2", "2", "33.8", "33.8", "A", "", "88.2", "86.7", "", "68.7", "", "2", "", "", "104", "1", "2", "50", "4", "0", "", "", "", "0", "", "", "", "", "1", "7.67", "0.171", "0.0075", "1.48868", "", "", "", "", "", "0", "", "", "8305", "", "A", "82", "XL", "92", "14", "83", "134.0", "87.9", "97.3", "", "", "", "", "95.5"]} +{"pcdb_id": 19268, "brand_name": "Worcester", "model_name": "Greenstar 8000 F", "model_qualifier": "GR8700iF 35 C LPG", "winter_efficiency_pct": 89.8, "summer_efficiency_pct": 88.4, "comparative_hot_water_efficiency_pct": 67.7, "output_kw_max": 33.8, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0095, "loss_factor_f1_kwh_per_day": 1.73552, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["019268", "020051", "0", "2025/Nov/27 10:13", "Bosch Thermotechnology Ltd", "Worcester", "Greenstar 8000 F", "GR8700iF 35 C LPG", "47-800-57", "2025", "current", "2", "1", "1", "2", "0", "", "", "2", "2", "2", "33.8", "33.8", "A", "", "89.8", "88.4", "", "67.7", "", "2", "0", "2", "104", "1", "2", "49", "4", "0", "", "", "", "0", "", "", "", "", "1", "7.955", "0.171", "0.0095", "1.73552", "", "", "", "", "", "0", "", "", "8305", "", "A", "83", "XL", "94", "15", "85", "134.0", "89.3", "98.5", "", "", "", "", "96.8"]} +{"pcdb_id": 19269, "brand_name": "Worcester", "model_name": "Greenstar 8000 F", "model_qualifier": "GR8700iF 50 C NG", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 86.3, "comparative_hot_water_efficiency_pct": 66.9, "output_kw_max": 47.8, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0065, "loss_factor_f1_kwh_per_day": 1.66434, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["019269", "020051", "0", "2025/Nov/27 10:46", "Bosch Thermotechnology Ltd", "Worcester", "Greenstar 8000 F", "GR8700iF 50 C NG", "47-800-58", "2025", "current", "1", "1", "1", "2", "0", "", "", "2", "2", "2", "47.8", "47.8", "A", "", "88.2", "86.3", "", "66.9", "", "2", "", "", "104", "1", "2", "86", "4", "0", "", "", "", "0", "", "", "", "", "1", "7.876", "0.169", "0.0065", "1.66434", "", "", "", "", "", "0", "", "", "8305", "", "A", "82", "XL", "93", "15", "106", "147.0", "86.9", "97.7", "", "", "", "", "95.6"]} +{"pcdb_id": 19270, "brand_name": "Worcester", "model_name": "Greenstar 8000 F", "model_qualifier": "GR8700iF 50 C LPG", "winter_efficiency_pct": 89.9, "summer_efficiency_pct": 88.7, "comparative_hot_water_efficiency_pct": 67.5, "output_kw_max": 47.8, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0085, "loss_factor_f1_kwh_per_day": 1.78375, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["019270", "020051", "0", "2025/Nov/27 11:07", "Bosch Thermotechnology Ltd", "Worcester", "Greenstar 8000 F", "GR8700iF 50 C LPG", "47-800-59", "2025", "current", "2", "1", "1", "2", "0", "", "", "2", "2", "2", "47.8", "47.8", "A", "", "89.9", "88.7", "", "67.5", "", "2", "0", "2", "104", "1", "2", "82", "4", "0", "", "", "", "0", "", "", "", "", "1", "7.972", "0.168", "0.0085", "1.78375", "", "", "", "", "", "0", "", "", "8305", "", "A", "83", "XL", "94", "16", "106", "147.0", "90.3", "98.5", "", "", "", "", "97.0"]} +{"pcdb_id": 19271, "brand_name": "Worcester", "model_name": "Greenstar 8000 F", "model_qualifier": "GR8700iF 35 R NG", "winter_efficiency_pct": 88.4, "summer_efficiency_pct": 79.4, "comparative_hot_water_efficiency_pct": 58.0, "output_kw_max": 33.8, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["019271", "020051", "0", "2025/Nov/27 11:27", "Bosch Thermotechnology Ltd", "Worcester", "Greenstar 8000 F", "GR8700iF 35 R NG", "41-800-41", "2025", "current", "1", "1", "1", "1", "0", "", "", "2", "2", "2", "33.8", "33.8", "A", "", "88.4", "79.4", "", "58.0", "", "2", "", "", "102", "1", "2", "51", "4", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "8305", "", "", "", "", "93", "14", "84", "90.0", "87.4", "97.9", "", "", "", "", "95.9"]} +{"pcdb_id": 19272, "brand_name": "Worcester", "model_name": "Greenstar 8000 F", "model_qualifier": "GR8700iF 35 R LPG", "winter_efficiency_pct": 89.9, "summer_efficiency_pct": 80.9, "comparative_hot_water_efficiency_pct": 59.1, "output_kw_max": 33.8, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["019272", "020051", "0", "2025/Nov/27 11:37", "Bosch Thermotechnology Ltd", "Worcester", "Greenstar 8000 F", "GR8700iF 35 R LPG", "41-800-42", "2025", "current", "2", "1", "1", "1", "0", "", "", "2", "2", "2", "33.8", "33.8", "A", "", "89.9", "80.9", "", "59.1", "", "2", "0", "2", "102", "1", "2", "50", "4", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "8305", "", "", "", "", "94", "13", "81", "90.0", "90.3", "98.6", "", "", "", "", "97.0"]} +{"pcdb_id": 19273, "brand_name": "Worcester", "model_name": "Greenstar 8000 F", "model_qualifier": "GR8700iF 50 R NG", "winter_efficiency_pct": 88.2, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 57.9, "output_kw_max": 47.8, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["019273", "020051", "0", "2025/Nov/27 13:24", "Bosch Thermotechnology Ltd", "Worcester", "Greenstar 8000 F", "GR8700iF 50 R NG", "41-800-43", "2025", "current", "1", "1", "1", "1", "0", "", "", "2", "2", "2", "47.8", "47.8", "A", "", "88.2", "79.2", "", "57.9", "", "2", "", "", "102", "1", "2", "86", "4", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "8305", "", "", "", "", "93", "15", "106", "98.0", "87.8", "97.4", "", "", "", "", "95.6"]} +{"pcdb_id": 19274, "brand_name": "Worcester", "model_name": "Greenstar 8000 F", "model_qualifier": "GR8700iF 50 R LPG", "winter_efficiency_pct": 90.0, "summer_efficiency_pct": 81.0, "comparative_hot_water_efficiency_pct": 59.2, "output_kw_max": 47.8, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["019274", "020051", "0", "2025/Nov/27 13:50", "Bosch Thermotechnology Ltd", "Worcester", "Greenstar 8000 F", "GR8700iF 50 R LPG", "41-800-44", "2025", "current", "2", "1", "1", "1", "0", "", "", "2", "2", "2", "47.8", "47.8", "A", "", "90.0", "81.0", "", "59.2", "", "2", "0", "2", "102", "1", "2", "82", "4", "0", "", "", "", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "8305", "", "", "", "", "94", "15", "104", "98.0", "91.5", "98.3", "", "", "", "", "97.0"]} +{"pcdb_id": 18861, "brand_name": "Glow-worm", "model_name": "Compact", "model_qualifier": "24c-AS/1 (H-GB)", "winter_efficiency_pct": 88.0, "summer_efficiency_pct": 86.6, "comparative_hot_water_efficiency_pct": 73.6, "output_kw_max": 18.3, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0008, "loss_factor_f1_kwh_per_day": 1.02612, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018861", "000207", "0", "2020/Jan/27 09:16", "Glow-worm", "Glow-worm", "Compact", "24c-AS/1 (H-GB)", "", "2019", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "18.3", "18.3", "", "", "88.0", "86.6", "", "73.6", "", "2", "", "", "104", "1", "2", " 27", " 2", "0", "", "", "", "0", "", "", "", "", "1", "7.151", "0.067", "0.0008", "1.02612", "", "", "", "", "", "", "", "", "0085", "", "", "", "", "", "", "", "", "87.8", "96.9", "", "", "", "", "95.1"]} +{"pcdb_id": 18862, "brand_name": "Glow-worm", "model_name": "Compact", "model_qualifier": "28c-AS/1 (H-GB)", "winter_efficiency_pct": 88.3, "summer_efficiency_pct": 86.6, "comparative_hot_water_efficiency_pct": 67.9, "output_kw_max": 23.9, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.0203, "loss_factor_f1_kwh_per_day": 1.49449, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018862", "000207", "0", "2020/Jan/27 09:16", "Glow-worm", "Glow-worm", "Compact", "28c-AS/1 (H-GB)", "", "2019", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "23.9", "23.9", "", "", "88.3", "86.6", "", "67.9", "", "2", "", "", "104", "1", "2", " 35", " 2", "0", "", "", "", "0", "", "", "", "", "1", "7.759", "0.07", "0.0203", "1.49449", "", "", "", "", "", "", "", "", "0085", "", "", "", "", "", "", "", "", "87.8", "97.7", "", "", "", "", "95.8"]} +{"pcdb_id": 18874, "brand_name": "Vaillant", "model_name": "ecoTEC plus 435", "model_qualifier": "VU 356/6-5 OVZ (H-GB)", "winter_efficiency_pct": 84.0, "summer_efficiency_pct": 74.0, "comparative_hot_water_efficiency_pct": null, "output_kw_max": 35.0, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["018874", "000031", "0", "2022/Oct/27 12:15", "Vaillant", "Vaillant", "ecoTEC plus 435", "VU 356/6-5 OVZ (H-GB)", "41-044-76", "2018", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "35", "35", "", "", "84.0", "74.0", "", "", "", "2", "", "", "102", "1", "2", "", "2", "0", "", "", "0", "0", "", "", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0045", "", "", "", "", "", "", "", "", "", "", "", "", "", "", ""]} +{"pcdb_id": 690201, "brand_name": "Generic Boiler", "model_name": "Hybrid Combi Boiler", "model_qualifier": "", "winter_efficiency_pct": 89.9, "summer_efficiency_pct": 86.7, "comparative_hot_water_efficiency_pct": null, "output_kw_max": null, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 1, "rejected_energy_proportion_r1": 0.004335, "loss_factor_f1_kwh_per_day": 1.00577248, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["690201", "300903", "0", "2023/Jan/30 08:51", "SAP Generic Products", "Generic Boiler", "Hybrid Combi Boiler", "", "", "2020", "current", "1", "0", "0", "2", "0", "", "", "2", "2", "2", "", "", "", "", "89.9", "86.7", "", "", "", "0", "", "", "0", "1", "2", "", "", "0", "", "", "", "0", "", "", "", "", "1", "7.122", "0.114", "0.004335", "1.00577248", "", "", "", "", "", "", "", "", "0005", "", "", "", "", "", "", "", "", "88.8", "97.8", "", "", "", "", ""]} +{"pcdb_id": 690001, "brand_name": "Illustrative Boiler", "model_name": "Regular", "model_qualifier": "Gas condensing", "winter_efficiency_pct": 89.9, "summer_efficiency_pct": 79.2, "comparative_hot_water_efficiency_pct": 53.3, "output_kw_max": 11.82, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["690001", "300900", "1", "2011/Sep/16 21:51", "SAP Illustrative Products", "Illustrative Boiler", "Regular", "Gas condensing", "", "2011", "current", "1", "2", "1", "1", "0", "", "", "2", "2", "2", "11.82", "11.82", "", "88.9", "89.9", "79.2", "0", "53.3", "", "2", "", "", "102", "1", "2", "80", "1.07", "0", "", "", "", "0.0", "", "0", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", ""]} +{"pcdb_id": 690002, "brand_name": "Illustrative Boiler", "model_name": "Instantaneous combi", "model_qualifier": "Gas condensing", "winter_efficiency_pct": 89.8, "summer_efficiency_pct": 79.7, "comparative_hot_water_efficiency_pct": 62.2, "output_kw_max": 11.82, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["690002", "300900", "1", "2011/Sep/16 21:51", "SAP Illustrative Products", "Illustrative Boiler", "Instantaneous combi", "Gas condensing", "", "2011", "current", "1", "2", "1", "2", "0", "", "", "2", "2", "2", "11.82", "11.82", "", "88.9", "89.8", "79.7", "0", "62.2", "", "2", "", "", "104", "1", "2", "80", "1.07", "0", "", "", "", "0.0", "", "0", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "0", "0005", "", "", "", "", ""]} +{"pcdb_id": 690003, "brand_name": "Illustrative Boiler", "model_name": "Storage combi", "model_qualifier": "Gas condensing", "winter_efficiency_pct": 90.1, "summer_efficiency_pct": 81.4, "comparative_hot_water_efficiency_pct": 66.0, "output_kw_max": 11.62, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 1, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["690003", "300900", "1", "2011/Sep/16 21:31", "SAP Illustrative Products", "Illustrative Boiler", "Storage combi", "Gas condensing", "", "2011", "current", "1", "1", "1", "2", "0", "", "", "2", "2", "2", "11.62", "11.62", "", "89.4", "90.1", "81.4", "0", "66.0", "", "2", "", "", "106", "1", "2", "", "", "1", "1", "0", "95", "0.0", "55", "2", "75", "60", "0", "", "", "", "", "", "", "", "", "", "", "", "0", "0005", "", "", "", "", ""]} +{"pcdb_id": 690004, "brand_name": "Illustrative Boiler", "model_name": "Regular", "model_qualifier": "LPG condensing", "winter_efficiency_pct": 91.1, "summer_efficiency_pct": 80.4, "comparative_hot_water_efficiency_pct": 51.4, "output_kw_max": 11.82, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["690004", "300900", "1", "2011/Sep/16 21:51", "SAP Illustrative Products", "Illustrative Boiler", "Regular", "LPG condensing", "", "2011", "current", "2", "2", "1", "1", "0", "", "", "2", "2", "2", "11.82", "11.82", "", "90.1", "91.1", "80.4", "0", "51.4", "", "2", "", "", "102", "1", "2", "80", "1.07", "0", "", "", "", "0.0", "", "0", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", ""]} +{"pcdb_id": 690005, "brand_name": "Illustrative Boiler", "model_name": "Instantaneous combi", "model_qualifier": "LPG condensing", "winter_efficiency_pct": 90.5, "summer_efficiency_pct": 80.9, "comparative_hot_water_efficiency_pct": 63.2, "output_kw_max": 11.82, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["690005", "300900", "1", "2011/Sep/16 21:51", "SAP Illustrative Products", "Illustrative Boiler", "Instantaneous combi", "LPG condensing", "", "2011", "current", "2", "2", "1", "2", "0", "", "", "2", "2", "2", "11.82", "11.82", "", "90.0", "90.5", "80.9", "0", "63.2", "", "2", "", "", "104", "1", "2", "80", "1.07", "0", "", "", "", "0.0", "", "0", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "0", "0005", "", "", "", "", ""]} +{"pcdb_id": 690006, "brand_name": "Illustrative Boiler", "model_name": "Regular", "model_qualifier": "Oil condensing", "winter_efficiency_pct": 92.0, "summer_efficiency_pct": 80.3, "comparative_hot_water_efficiency_pct": 54.0, "output_kw_max": 12.82, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 0, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["690006", "300900", "1", "2011/Sep/16 21:51", "SAP Illustrative Products", "Illustrative Boiler", "Regular", "Oil condensing", "", "2011", "current", "4", "2", "1", "1", "0", "", "", "2", "2", "2", "12.82", "12.82", "", "90.9", "92.0", "80.3", "0", "54.0", "", "2", "", "", "201", "1", "1", "80", "1.07", "0", "", "", "", "0.0", "", "0", "", "", "0", "", "", "", "", "", "", "", "", "", "", "", "", "0005", "", "", "", "", ""]} +{"pcdb_id": 690007, "brand_name": "Illustrative Boiler", "model_name": "Storage combi", "model_qualifier": "Oil condensing", "winter_efficiency_pct": 90.1, "summer_efficiency_pct": 82.1, "comparative_hot_water_efficiency_pct": 62.5, "output_kw_max": 12.82, "final_year_of_manufacture": null, "subsidiary_type": 0, "store_type": 1, "separate_dhw_tests": 0, "rejected_energy_proportion_r1": null, "loss_factor_f1_kwh_per_day": null, "loss_factor_f2_kwh_per_day": null, "rejected_factor_f3_per_litre": null, "raw": ["690007", "300900", "1", "2011/Sep/16 21:02", "SAP Illustrative Products", "Illustrative Boiler", "Storage combi", "Oil condensing", "", "2011", "current", "4", "1", "2", "2", "0", "", "", "2", "2", "2", "12.82", "12.82", "", "89.3", "90.1", "82.1", "0", "62.5", "", "2", "", "", "203", "1", "1", "240", "", "1", "1", "0", "69", "0.0", "25", "3", "82", "", "0", "", "", "", "", "", "", "", "", "", "", "", "0", "0005", "", "", "", "", ""]} diff --git a/packages/domain/src/domain/sap/rdsap/cert_to_inputs.py b/packages/domain/src/domain/sap/rdsap/cert_to_inputs.py index bc8f95c0..64770d46 100644 --- a/packages/domain/src/domain/sap/rdsap/cert_to_inputs.py +++ b/packages/domain/src/domain/sap/rdsap/cert_to_inputs.py @@ -54,6 +54,7 @@ from domain.ml.sap_efficiencies import ( ) from domain.sap.calculator import CalculatorInputs from domain.sap.tables.pcdb import gas_oil_boiler_record +from domain.sap.tables.pcdb.parser import GasOilBoilerRecord from domain.sap.tables.table_12 import ( co2_factor_kg_per_kwh, primary_energy_factor, @@ -97,6 +98,7 @@ from domain.sap.worksheet.ventilation import ( ) from domain.sap.worksheet.water_heating import ( TABLE_J1_TCOLD_FROM_MAINS_C, + combi_loss_monthly_kwh_table_3b_row_1_instantaneous, water_heating_from_cert, ) @@ -709,12 +711,47 @@ def _has_bath_from_cert(epc: EpcPropertyData) -> bool: return n is None or n >= 1 +def _pcdb_table_3b_combi_loss_override( + pcdb_record: Optional[GasOilBoilerRecord], + *, + energy_content_monthly_kwh: tuple[float, ...], + daily_hot_water_monthly_l_per_day: tuple[float, ...], +) -> Optional[tuple[float, ...]]: + """Build a Table 3b row-1 combi-loss override when the PCDB record + lodges single-profile (Profile M only) test data for an instantaneous + combi with non-storage FGHRS or without FGHRS. Returns None for + every other PCDB combi configuration so the worksheet falls back to + the Table 3a default. Other Table 3b/3c rows (storage variants, + integral FGHRS, two-profile Table 3c) are deferred until a fixture + exercises them — defaulting to Table 3a is safe (matches the pre- + §4 behaviour) but loses spec accuracy for those configurations.""" + if pcdb_record is None: + return None + if pcdb_record.separate_dhw_tests != 1: + return None + if pcdb_record.subsidiary_type not in (None, 0): + return None + if pcdb_record.store_type not in (None, 0): + return None + r1 = pcdb_record.rejected_energy_proportion_r1 + f1 = pcdb_record.loss_factor_f1_kwh_per_day + if r1 is None or f1 is None: + return None + return combi_loss_monthly_kwh_table_3b_row_1_instantaneous( + rejected_energy_proportion_r1=r1, + loss_factor_f1_kwh_per_day=f1, + energy_content_monthly_kwh=energy_content_monthly_kwh, + daily_hot_water_monthly_l_per_day=daily_hot_water_monthly_l_per_day, + ) + + def _hot_water_fuel_kwh_per_yr( *, epc: EpcPropertyData, water_efficiency_pct: float, is_instantaneous: bool, primary_age: Optional[str], + pcdb_record: Optional[GasOilBoilerRecord] = None, ) -> tuple[float, tuple[float, ...]]: """Annual hot water FUEL kWh (the slot calculator.CalculatorInputs expects). Wires the SAP10.2 §4 worksheet orchestrator into the cert→ @@ -753,6 +790,25 @@ def _hot_water_fuel_kwh_per_yr( has_solar_water_heating=epc.solar_water_heating, ) return legacy_kwh, zero_monthly + # If the PCDB record carries Profile-M combi-test data (separate_dhw_ + # tests=1, instantaneous non-storage), pre-build the (61)m override + # so `water_heating_from_cert` uses Table 3b row 1 instead of the + # Table 3a default. Requires (45)m and (44)m from a prior orchestrator + # invocation; cheapest to call the orchestrator twice (once to derive + # the inputs to the override, once to land the final result with the + # override in place). + bootstrap = water_heating_from_cert( + epc=epc, + mixer_shower_flow_rates_l_per_min=_mixer_shower_flow_rates_from_cert(epc), + has_bath=_has_bath_from_cert(epc), + cold_water_temps_c=TABLE_J1_TCOLD_FROM_MAINS_C, + low_water_use=False, + ) + combi_loss_override = _pcdb_table_3b_combi_loss_override( + pcdb_record, + energy_content_monthly_kwh=bootstrap.energy_content_monthly_kwh, + daily_hot_water_monthly_l_per_day=bootstrap.daily_hot_water_l_per_day_monthly, + ) result = water_heating_from_cert( epc=epc, mixer_shower_flow_rates_l_per_min=_mixer_shower_flow_rates_from_cert(epc), @@ -762,6 +818,7 @@ def _hot_water_fuel_kwh_per_yr( # a domain-model field + plumb-through in a future slice. cold_water_temps_c=TABLE_J1_TCOLD_FROM_MAINS_C, low_water_use=False, + combi_loss_monthly_kwh_override=combi_loss_override, ) if water_efficiency_pct <= 0: return 0.0, result.heat_gains_monthly_kwh @@ -1035,6 +1092,7 @@ def cert_to_inputs( water_efficiency_pct=water_eff, is_instantaneous=is_instantaneous, primary_age=primary_age, + pcdb_record=pcdb_main, ) lighting_kwh = predicted_lighting_kwh( total_floor_area_m2=epc.total_floor_area_m2, diff --git a/packages/domain/src/domain/sap/tables/pcdb/__init__.py b/packages/domain/src/domain/sap/tables/pcdb/__init__.py index a2fc3364..b9c06a79 100644 --- a/packages/domain/src/domain/sap/tables/pcdb/__init__.py +++ b/packages/domain/src/domain/sap/tables/pcdb/__init__.py @@ -61,6 +61,13 @@ def _load_table_105() -> dict[int, GasOilBoilerRecord]: comparative_hot_water_efficiency_pct=data["comparative_hot_water_efficiency_pct"], output_kw_max=data["output_kw_max"], final_year_of_manufacture=data["final_year_of_manufacture"], + subsidiary_type=data.get("subsidiary_type"), + store_type=data.get("store_type"), + separate_dhw_tests=data.get("separate_dhw_tests"), + rejected_energy_proportion_r1=data.get("rejected_energy_proportion_r1"), + loss_factor_f1_kwh_per_day=data.get("loss_factor_f1_kwh_per_day"), + loss_factor_f2_kwh_per_day=data.get("loss_factor_f2_kwh_per_day"), + rejected_factor_f3_per_litre=data.get("rejected_factor_f3_per_litre"), raw=tuple(data["raw"]), ) records_by_id[record.pcdb_id] = record diff --git a/packages/domain/src/domain/sap/tables/pcdb/parser.py b/packages/domain/src/domain/sap/tables/pcdb/parser.py index 9cbb3904..163ee812 100644 --- a/packages/domain/src/domain/sap/tables/pcdb/parser.py +++ b/packages/domain/src/domain/sap/tables/pcdb/parser.py @@ -64,6 +64,24 @@ class GasOilBoilerRecord: comparative_hot_water_efficiency_pct: Optional[float] output_kw_max: Optional[float] final_year_of_manufacture: Optional[int] + # SAP10.2 Appendix J Table 3b/3c — combi-loss fields per BRE PCDF + # Spec v1.0 §7.11 fields 48 / 51 / 52 / 56 / 57. Populated only for + # boilers EN 13203-2 / OPS 26 tested; SAP-default boilers leave them + # all blank → `separate_dhw_tests=0` and (61)m falls back to Table 3a. + # BRE PCDF Spec v1.0 §7.11 field 16 (0-idx 15): 0=normal, 1=integral + # FGHRS, 2=combined HP+boiler, 3=combined HP+boiler+FGHRS. Gates the + # Table 3b/3c row selection — only `subsidiary_type=0` exercises the + # "Instantaneous with non-storage FGHRS or without FGHRS" row 1. + subsidiary_type: Optional[int] + # BRE PCDF Spec v1.0 §7.11 field 39 (0-idx 38): 0=not storage combi, + # 1=primary water store, 2=secondary store, 3=CPSU. Gates storage- + # combi rows in Table 3b/3c (deferred until a fixture exercises). + store_type: Optional[int] + separate_dhw_tests: Optional[int] + rejected_energy_proportion_r1: Optional[float] + loss_factor_f1_kwh_per_day: Optional[float] + loss_factor_f2_kwh_per_day: Optional[float] + rejected_factor_f3_per_litre: Optional[float] raw: tuple[str, ...] @@ -141,5 +159,12 @@ def parse_table_105_row(row: str) -> GasOilBoilerRecord: winter_efficiency_pct=_parse_optional_float(fields[25]), summer_efficiency_pct=_parse_optional_float(fields[26]), comparative_hot_water_efficiency_pct=_parse_optional_float(fields[28]), + subsidiary_type=_parse_optional_int(fields[15]), + store_type=_parse_optional_int(fields[38]), + separate_dhw_tests=_parse_optional_int(fields[47]), + rejected_energy_proportion_r1=_parse_optional_float(fields[50]), + loss_factor_f1_kwh_per_day=_parse_optional_float(fields[51]), + loss_factor_f2_kwh_per_day=_parse_optional_float(fields[55]), + rejected_factor_f3_per_litre=_parse_optional_float(fields[56]), raw=fields, ) diff --git a/packages/domain/src/domain/sap/tests/test_pcdb_etl.py b/packages/domain/src/domain/sap/tests/test_pcdb_etl.py index befd8e18..71b57a0f 100644 --- a/packages/domain/src/domain/sap/tests/test_pcdb_etl.py +++ b/packages/domain/src/domain/sap/tests/test_pcdb_etl.py @@ -34,6 +34,22 @@ _BAXI_98_RAW: str = ( ",,0,,0,,0,,,,,0,,,,,,,,,,,,,0000,,,,,,,,,,,,,,," ) +# Verified by ground-truth arithmetic against PDF Σ(61) = 337.19 for 000474 +# Elmhurst fixture (Vaillant ecoTEC pro 28 VUW GB 286/5-3, pcdb_id 16839): +# Table 3b row 1 → Σ(61) = (45) × r1 × fu + F1 × 365 +# = 1680.84 × 0.0025 × 1.0 + 0.91251 × 365 = 337.27. +# Combi-loss fields (BRE PCDF Spec v1.0 §7.11 fields 48/51/52/56/57): +# separate_dhw_tests = 1 (one test, profile M → Table 3b) +# rejected_energy_proportion_r1 = 0.0025 +# loss_factor_f1_kwh_per_day = 0.91251 +# loss_factor_f2 / rejected_factor_f3 = blank (Table 3c not used) +_VAILLANT_16839_RAW: str = ( + "016839,000031,0,2019/Mar/04 10:28,Vaillant,Vaillant,ecoTEC pro 28," + "VUW GB 286/5-3,GC 47-044-45,2005,2015,1,2,1,2,0,,,2,2,2,24.4,24.4,,," + "88.7,87.0,,75.1,,2,,,104,1,2,105,2,0,,,,0,,,,,1,7.012,0.133,0.0025," + "0.91251,,,,,,1,1,,0045,,,,,,,,,89.0,98.0,,,,,96.3" +) + def test_table_105_parser_extracts_baxi_98_known_fields() -> None: """Decode the user-verified Baxi 000098 Wm 20/3rs record. Field positions @@ -116,6 +132,63 @@ def test_table_105_parser_extracts_other_user_verified_records( assert getattr(record, key) == value, f"field {key}" +def test_table_105_parser_extracts_separate_dhw_tests_profile_flag() -> None: + """BRE PCDF Spec v1.0 §7.11 field 48 (0-indexed 47) "Separate DHW + tests" encodes the profile-flag for PCDB Table 3b/3c combi-loss + selection: 0 = none / not applicable, 1 = one test profile M + (Table 3b), 2 = two tests profiles M+L (Table 3c), 3 = two tests + profiles M+S (Table 3c). 16839 lodges flag=1 → Table 3b path.""" + # Arrange + raw_row = _VAILLANT_16839_RAW + + # Act + record = parse_table_105_row(raw_row) + + # Assert + assert record.separate_dhw_tests == 1 + + +def test_table_105_parser_extracts_table_3b_3c_combi_loss_coefficients() -> None: + """BRE PCDF Spec v1.0 §7.11 fields 51 / 52 / 56 / 57 (0-indexed + 50 / 51 / 55 / 56) carry the Table 3b/3c combi-loss coefficients: + rejected energy r1, loss factor F1 (Table 3b), loss factor F2 + (Table 3c), rejected factor F3 (Table 3c, can be negative). + 16839 lodges profile M only, so F2/F3 are absent (blank). Cross- + verified by arithmetic: Σ(61) = (45) × r1 × fu + F1 × 365 + = 1680.84 × 0.0025 × 1.0 + 0.91251 × 365 = 337.27 kWh/yr against + the 000474 worksheet's PDF pin Σ(61) = 337.19 (Δ 0.02%).""" + # Arrange + raw_row = _VAILLANT_16839_RAW + + # Act + record = parse_table_105_row(raw_row) + + # Assert + assert record.rejected_energy_proportion_r1 == 0.0025 + assert record.loss_factor_f1_kwh_per_day == 0.91251 + assert record.loss_factor_f2_kwh_per_day is None + assert record.rejected_factor_f3_per_litre is None + + +def test_table_105_parser_leaves_combi_loss_fields_none_for_sap_default_boilers() -> None: + """Baxi 000098 is a SAP-default boiler (no EN 13203-2 / OPS 26 tests), + so the Table 3b/3c combi-loss fields are blank in pcdb10.dat. The + parser exposes them as None to signal Table 3a fallback (the + pre-§4-HW default 600 kWh/yr behaviour).""" + # Arrange + raw_row = _BAXI_98_RAW + + # Act + record = parse_table_105_row(raw_row) + + # Assert + assert record.separate_dhw_tests == 0 + assert record.rejected_energy_proportion_r1 is None + assert record.loss_factor_f1_kwh_per_day is None + assert record.loss_factor_f2_kwh_per_day is None + assert record.rejected_factor_f3_per_litre is None + + def test_parse_table_105_walks_section_skipping_headers_and_comments() -> None: """The .dat file demarcates each table with a `$,,...` header line, intersperses `#`-prefixed comments, and ends the table diff --git a/packages/domain/src/domain/sap/worksheet/tests/test_water_heating.py b/packages/domain/src/domain/sap/worksheet/tests/test_water_heating.py index f0126218..6418757f 100644 --- a/packages/domain/src/domain/sap/worksheet/tests/test_water_heating.py +++ b/packages/domain/src/domain/sap/worksheet/tests/test_water_heating.py @@ -24,6 +24,7 @@ from domain.sap.worksheet.water_heating import ( annual_average_hot_water_other_uses_l_per_day, assumed_occupancy, combi_loss_monthly_kwh_table_3a_keep_hot_time_clock, + combi_loss_monthly_kwh_table_3b_row_1_instantaneous, distribution_loss_monthly_kwh, energy_content_of_hot_water_monthly_kwh, heat_gains_from_water_heating_monthly_kwh, @@ -474,6 +475,60 @@ def test_distribution_loss_zero_for_instantaneous_point_of_use_water_heating() - assert all(v == pytest.approx(0.0, abs=1e-9) for v in loss) +def test_combi_loss_table_3b_row_1_matches_elmhurst_000474_pcdb_arithmetic() -> None: + """SAP10.2 Appendix J Table 3b row 1 (Instantaneous with non-storage + FGHRS or without FGHRS): + (61)m = (45)m × r1 × fu + [F1 × n_m] + + where r1, F1 are PCDB Table 105 fields and fu = V_d,m/100 for daily + HW < 100 L/day, else 1.0. + + For 000474 (Vaillant ecoTEC pro 28, PCDB 16839): r1 = 0.0025, + F1 = 0.91251 kWh/day, V_d,m > 100 ⇒ fu = 1.0 every month. + Σ(61) = 0.0025 × Σ(45) + 0.91251 × 365 = 4.20 + 333.07 = 337.27 + against PDF pin Σ(61) = 337.19 (Δ 0.02%, rounding-floor).""" + # Arrange + r1 = 0.0025 + f1 = 0.91251 + energy_content_45 = _w000474.LINE_45_M_HW_ENERGY_CONTENT_KWH + # Daily HW > 100 L/day every month for 000474 → fu collapses to 1.0. + daily_hw_44 = _w000474.LINE_44_M_DAILY_HW_USAGE_L + + # Act + monthly = combi_loss_monthly_kwh_table_3b_row_1_instantaneous( + rejected_energy_proportion_r1=r1, + loss_factor_f1_kwh_per_day=f1, + energy_content_monthly_kwh=energy_content_45, + daily_hot_water_monthly_l_per_day=daily_hw_44, + ) + + # Assert + assert sum(monthly) == pytest.approx(337.27, abs=0.10) + # Per-month also: Jan = (174.4 × 0.0025 × 1.0) + (0.91251 × 31) = 28.7271 + assert monthly[0] == pytest.approx(_w000474.LINE_61_M_COMBI_LOSS_KWH[0], abs=0.05) + + +def test_000474_cert_to_inputs_hot_water_kwh_closes_within_1_5pct_via_pcdb_table_3b() -> None: + """Cert-round-trip conformance: 000474 mid-terrace combi-gas (PDF + HW fuel = 2291.78 kWh/yr). Pre-§4 slice 1: cert_to_inputs used + Table 3a default 600 kWh/yr combi loss → HW fuel 2621.65 (+14.4%). + Post-§4 slice 1: cert_to_inputs reads PCDB Table 105 r1/F1 fields + and routes through Table 3b row 1 (Σ(61) = 337.27) → HW fuel 2319.7 + (+1.2%). The remaining ~1.2% residual closes when slice 2 promotes + `water_efficiency_pct` from the scalar summer efficiency to the + monthly Equation D1 cascade (Appendix D §D2.1 (2)).""" + # Arrange + from domain.sap.rdsap.cert_to_inputs import cert_to_inputs + + epc = _w000474.build_epc() + + # Act + inputs = cert_to_inputs(epc) + + # Assert + assert inputs.hot_water_kwh_per_yr == pytest.approx(2291.78, rel=0.015) + + def test_combi_loss_table_3a_time_clock_keep_hot_matches_elmhurst_000490() -> None: """SAP10.2 §4 line (61)m via Table 3a row "Instantaneous, with keep-hot facility controlled by time clock": diff --git a/packages/domain/src/domain/sap/worksheet/water_heating.py b/packages/domain/src/domain/sap/worksheet/water_heating.py index 51729bac..911863d9 100644 --- a/packages/domain/src/domain/sap/worksheet/water_heating.py +++ b/packages/domain/src/domain/sap/worksheet/water_heating.py @@ -264,6 +264,39 @@ def distribution_loss_monthly_kwh( return tuple(0.15 * e for e in monthly_energy_content_kwh) +def combi_loss_monthly_kwh_table_3b_row_1_instantaneous( + *, + rejected_energy_proportion_r1: float, + loss_factor_f1_kwh_per_day: float, + energy_content_monthly_kwh: tuple[float, ...], + daily_hot_water_monthly_l_per_day: tuple[float, ...], +) -> tuple[float, ...]: + """SAP 10.2 Appendix J Table 3b row 1 (Instantaneous combi with non- + storage FGHRS or without FGHRS, profile M only): + + (61)m = (45)m × r1 × fu + [F1 × n_m] + + where r1 = rejected energy proportion (PCDB Table 105 field 51), + F1 = loss factor in kWh/day (PCDB field 52), and fu = V_d,m / 100 + when daily hot-water usage V_d,m < 100 L/day, else fu = 1.0. + + Applies only to combi boilers EN 13203-2 / OPS 26 tested with one + profile (Separate DHW tests = 1). Other Table 3b rows (storage + combis, storage-FGHRS variants) and Table 3c (two-profile tests) + are deferred until a fixture exercises them. Untested combis fall + back to the existing Table 3a path. + """ + return tuple( + e * rejected_energy_proportion_r1 * (v / 100.0 if v < 100.0 else 1.0) + + loss_factor_f1_kwh_per_day * n + for e, v, n in zip( + energy_content_monthly_kwh, + daily_hot_water_monthly_l_per_day, + _DAYS_IN_MONTH, + ) + ) + + def combi_loss_monthly_kwh_table_3a_keep_hot_time_clock() -> tuple[float, ...]: """SAP 10.2 §4 line (61)m — Table 3a row "Instantaneous, with keep-hot facility controlled by time clock": 600 × n_m / 365 kWh/month.